Sample records for source insertion device

  1. Field errors in hybrid insertion devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schlueter, R.D.

    1995-02-01

    Hybrid magnet theory as applied to the error analyses used in the design of Advanced Light Source (ALS) insertion devices is reviewed. Sources of field errors in hybrid insertion devices are discussed.

  2. Vacuum-actuated percutaneous insertion/implantation tool for flexible neural probes and interfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheth, Heeral; Bennett, William J.; Pannu, Satinderpall S.

    A flexible device insertion tool including an elongated stiffener with one or more suction ports, and a vacuum connector for interfacing the stiffener to a vacuum source, for attaching the flexible device such as a flexible neural probe to the stiffener during insertion by a suction force exerted through the suction ports to, and to release the flexible device by removing the suction force.

  3. Development of a Hard X-ray Beam Position Monitor for Insertion Device Beams at the APS

    NASA Astrophysics Data System (ADS)

    Decker, Glenn; Rosenbaum, Gerd; Singh, Om

    2006-11-01

    Long-term pointing stability requirements at the Advanced Photon Source (APS) are very stringent, at the level of 500 nanoradians peak-to-peak or better over a one-week time frame. Conventional rf beam position monitors (BPMs) close to the insertion device source points are incapable of assuring this level of stability, owing to mechanical, thermal, and electronic stability limitations. Insertion device gap-dependent systematic errors associated with the present ultraviolet photon beam position monitors similarly limit their ability to control long-term pointing stability. We report on the development of a new BPM design sensitive only to hard x-rays. Early experimental results will be presented.

  4. Status of the Superconducting Insertion Device Control at TLS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, K. H.; Wang, C. J.; Lee, Demi

    2007-01-19

    Superconducting insertion devices are installed at Taiwan Light Source to meet the rapidly growing demand of X-ray users. A control system supports the operation of all these superconducting insertion devices. Control system coordinates the operation of the main power supply and the trimming power supply to charge/discharge the magnet and provide essential interlock protection for the coils and vacuum ducts. Quench protection and various cryogenic interlocks are designed to prevent damage to the magnet. A friendly user interface supports routine operation. Various applications are also developed to aid the operation of these insertion devices. Design consideration and details of themore » implementation will be summarized in this report.« less

  5. NSLS-II storage ring insertion device and front-end commissioning and operation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, G., E-mail: gwang@bnl.gov; Shaftan, T.; Amundsen, C.

    The National Synchrotron Light Source II (NSLS-II) is a state of the art 3 GeV third generation light source at Brookhaven National Laboratory. During spring/ summer of 2014, the storage ring was commissioned up to 50 mA without insertion devices. In the fall of 2014, we began commissioning of the project beamlines, which included seven insertion devices on six ID ports. Beamlines IXS, HXN, CSX-1, CSX-2, CHX, SRX, and XPD-1 consist of elliptically polarized undulator (EPU), damping wigglers (DW) and in-vacuum undulators (IVU) covering from VUV to hard x-ray range. In this paper, experience with commissioning and operation is discussed.more » We focus on reaching storage ring performance with IDs, including injection, design emittance, compensation of orbit distortions caused by ID residual field, source point stability, beam alignment and tools for control, monitoring and protection of the ring chambers from ID radiation.« less

  6. Spectral analysis of hearing protector impulsive insertion loss

    PubMed Central

    Fackler, Cameron J.; Berger, Elliott H.; Murphy, William J.; Stergar, Michael E.

    2017-01-01

    Objective To characterize the performance of hearing protection devices in impulsive-noise conditions and to compare various protection metrics between impulsive and steady-state noise sources with different characteristics. Design Hearing protectors were measured per the impulsive test methods of ANSI/ASA S12.42-2010. Protectors were measured with impulses generated by both an acoustic shock tube and an AR-15 rifle. The measured data were analyzed for impulse peak insertion loss (IPIL) and impulsive spectral insertion loss (ISIL). These impulsive measurements were compared to insertion loss measured with steady-state noise and with real-ear attenuation at threshold (REAT). Study Sample Tested devices included a foam earplug, a level-dependent earplug, and an electronic sound-restoration earmuff. Results IPIL for a given protector varied between measurements with the two impulse noise sources, but ISIL agreed between the two sources. The level-dependent earplug demonstrated level-dependent effects both in IPIL and ISIL. Steady-state insertion loss and REAT measurements tended to provide a conservative estimate of the impulsively-measured attenuation. Conclusions Measurements of IPIL depend strongly on the source used to measure them, especially for hearing protectors with less attenuation at low frequencies. ISIL provides an alternative measurement of impulse protection and appears to be a more complete description of an HPD’s performance. PMID:27885881

  7. Monitored separation device

    NASA Technical Reports Server (NTRS)

    Fox, George Edward (Inventor); Jackson, George William (Inventor); Willson, Richard Coale (Inventor)

    2011-01-01

    A device for separating and purifying useful quantities of particles comprises: a. an anolyte reservoir connected to an anode, the anolyte reservoir containing an electrophoresis buffer; b. a catholyte reservoir connected to a cathode, the catholyte reservoir also containing the electrophoresis buffer; c. a power supply connected to the anode and to the cathode; d. a column having a first end inserted into the anolyte reservoir, a second end inserted into the catholyte reservoir, and containing a separation medium; e. a light source; f. a first optical fiber having a first fiber end inserted into the separation medium, and having a second fiber end connected to the light source; g. a photo detector; h. a second optical fiber having a third fiber end inserted into the separation medium, and having a fourth fiber end connected to the photo detector; and i. an ion-exchange membrane in the anolyte reservoir.

  8. APS undulator and wiggler sources: Monte-Carlo simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, S.L.; Lai, B.; Viccaro, P.J.

    1992-02-01

    Standard insertion devices will be provided to each sector by the Advanced Photon Source. It is important to define the radiation characteristics of these general purpose devices. In this document,results of Monte-Carlo simulation are presented. These results, based on the SHADOW program, include the APS Undulator A (UA), Wiggler A (WA), and Wiggler B (WB).

  9. Characterizing permanent magnet blocks with Helmholtz coils

    NASA Astrophysics Data System (ADS)

    Carnegie, D. W.; Timpf, J.

    1992-08-01

    Most of the insertion devices to be installed at the Advanced Photon Source will utilize permanent magnets in their magnetic structures. The quality of the spectral output is sensitive to the errors in the field of the device which are related to variations in the magnetic properties of the individual blocks. The Advanced Photon Source will have a measurement facility to map the field in the completed insertion devices and equipment to test and modify the magnetic strength of the individual magnet blocks. One component of the facility, the Helmholtz coil permanent magnet block measurement system, has been assembled and tested. This system measures the total magnetic moment vector of a block with a precision better than 0.01% and a directional resolution of about 0.05°. The design and performance of the system will be presented.

  10. Effect of inserted metal at anode tip on formation of pulsed X-ray emitting zone of plasma focus device

    NASA Astrophysics Data System (ADS)

    Miremad, Seyed Milad; Shirani Bidabadi, Babak

    2018-04-01

    The effect of the anode's insert material of a plasma focus device on the properties of X-ray emission zone was studied. Inserts were fabricated out of six different materials including aluminum, copper, zinc, tin, tungsten, and lead to cover a wide range of atomic numbers. For each anode's insert material at different gas pressures and different voltages, the shape of X-ray emission zone was recorded by three pinhole cameras, which were installed on sidewall and roof of the chamber of plasma focus device. The results indicated that by changing the gas pressure and the charge voltage of capacitor, the X-ray source of plasma focus emerges with different forms as a concentrated column or conical shape with sharp or cloudy edges. These structures are in the form of a combination of plasma emission and anode-tip emission with different intensities. These observations indicate that the material of the anode-tip especially affects the structure of X-ray emission zone.

  11. FEL (free-electron lasers) undulator technology and synchrotron radiation source requirements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, K.; Quimby, D.; Slater, J.

    This paper describes design and construction considerations of the THUNDER undulator, for use in free-electron laser experiments at visible wavelengths. For the parameters of these experiments, an unusually high degree of optimization of the electron-photon interaction is required and, as a result, THUNDER is built to especially high mechanical and magnetic precision. Except for its narrow magnet gap, the 5-meter THUNDER undulator is quite similar to insertion devices under consideration for the proposed 6-GeV storage ring. The engineering and physics approach adopted for this FEL modulator design is directly applicable to insertion device development. The tolerance limits to THUNDER, establishedmore » by modeling and design and achieved through careful control of mechanical and magnetic errors, are essential to the next generation of insertion devices.« less

  12. Study to Expand Simulation Cockpit Displays of Advanced Sensors

    DTIC Science & Technology

    1981-03-01

    common source is being used for multiple sensor types). If inde- pendent displays and controls are desired then two independent video sources or sensor...line is inserted in each gap, the result is the familiar 211 in- terlace. If two lines are inserted, the result is 31l interlace, and so on. The total...symbol generators. If these systems are oper- ating at various scan rates and if a common display device, such as a multifunction display (MFD) is to

  13. A Superconducting Switch for Insertion Devices with Variable Period Length

    NASA Astrophysics Data System (ADS)

    Holubek, T.; Baumbach, T.; Casalbuoni, S.; Gerstl, S.; Grau, A.; Hagelstein, M.; Jauregui, D. Saez de; Boffo, C.; Walter, W.

    Superconducting insertion devices (IDs) are very attractive for synchrotron light sources since they offer the possibility to enhance the tuning range and functionality significantly by period length switching. Period length switching can be realized by reversing the current in a separately powered subset of the superconducting windings.So far, the first demonstration mock-up coil allowing period length tripling was fabricated and tested successfully. Here, we report on the feasibility of superconducting switches built to operate in a liquid helium bath and under conduction cooled conditions.

  14. Descemet's Stripping Automated Endothelial Keratoplasty Tissue Insertion Devices

    PubMed Central

    Khan, Salman Nasir; Shiakolas, Panos S.; Mootha, Venkateswara Vinod

    2015-01-01

    This review study provides information regarding the construction, design, and use of six commercially available endothelial allograft insertion devices applied for Descemet's stripping automated endothelial keratoplasty (DSAEK). We also highlight issues being faced in DSAEK and discuss the methods through which medical devices such as corneal inserters may alleviate these issues. Inserter selection is of high importance in the DSAEK procedure since overcoming the learning curve associated with the use of an insertion device is a time and energy consuming process. In the present review, allograft insertion devices were compared in terms of design, construction material, insertion technique, dimensions, incision requirements and endothelial cell loss to show their relative merits and capabilities based on available data in the literature. Moreover, the advantages/disadvantages of various insertion devices used for allograft insertion in DSAEK are reviewed and compared. The information presented in this review can be utilized for better selection of an insertion device for DSAEK. PMID:27051492

  15. Method for Monitored Separation and Collection of Biological Materials

    NASA Technical Reports Server (NTRS)

    Fox, George Edward (Inventor); Jackson, George William (Inventor); Willson, Richard Coale (Inventor)

    2014-01-01

    A device for separating and purifying useful quantities of particles comprises: (a) an anolyte reservoir connected to an anode, the anolyte reservoir containing an electrophoresis buffer; (b) a catholyte reservoir connected to a cathode, the catholyte reservoir also containing the electrophoresis buffer; (c) a power supply connected to the anode and to the cathode; (d) a column having a first end inserted into the anolyte reservoir, a second end inserted into the catholyte reservoir, and containing a separation medium; (e) a light source; (f) a first optical fiber having a first fiber end inserted into the separation medium, and having a second fiber end connected to the light source; (g) a photo detector; (h) a second optical fiber having a third fiber end inserted into the separation medium, and having a fourth fiber end connected to the photo detector; and (i) an ion-exchange membrane in the anolyte reservoir.

  16. 21 CFR 886.5420 - Contact lens inserter/remover.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contact lens inserter/remover. 886.5420 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5420 Contact lens inserter/remover. (a) Identification. A contact lens inserter/remover is a handheld device intended to insert or remove...

  17. Spectral analysis of hearing protector impulsive insertion loss.

    PubMed

    Fackler, Cameron J; Berger, Elliott H; Murphy, William J; Stergar, Michael E

    2017-01-01

    To characterise the performance of hearing protection devices (HPDs) in impulsive-noise conditions and to compare various protection metrics between impulsive and steady-state noise sources with different characteristics. HPDs were measured per the impulsive test methods of ANSI/ASA S12.42- 2010 . Protectors were measured with impulses generated by both an acoustic shock tube and an AR-15 rifle. The measured data were analysed for impulse peak insertion loss (IPIL) and impulsive spectral insertion loss (ISIL). These impulsive measurements were compared to insertion loss measured with steady-state noise and with real-ear attenuation at threshold (REAT). Tested HPDs included a foam earplug, a level-dependent earplug and an electronic sound-restoration earmuff. IPIL for a given protector varied between measurements with the two impulse noise sources, but ISIL agreed between the two sources. The level-dependent earplug demonstrated level-dependent effects both in IPIL and ISIL. Steady-state insertion loss and REAT measurements tended to provide a conservative estimate of the impulsively-measured attenuation. Measurements of IPIL depend strongly on the source used to measure them, especially for HPDs with less attenuation at low frequencies. ISIL provides an alternative measurement of impulse protection and appears to be a more complete description of an HPD's performance.

  18. A transverse bunch by bunch feedback system for Pohang Light Source upgrade

    NASA Astrophysics Data System (ADS)

    Lee, E.-H.; Kim, D.-T.; Huang, J.-Y.; Shin, S.; Nakamura, T.; Kobayashi, K.

    2014-12-01

    The Pohang Light Source upgrade (PLS-II) project has successfully upgraded the Pohang Light Source (PLS). The main goals of the PLS-II project are to increase the beam energy to 3 GeV, increase the number of insertion devices by a factor of two (20 IDs), increase the beam current to 400 mA, and at the same time reduce the beam emittance to below 10 nm by using the existing PLS tunnel and injection system. Among 20 insertion devices, 10 narrow gap in-vacuum undulators are in operation now and two more in-vacuum undulators are to be installed later. Since these narrow gap in-vacuum undulators are most likely to produce coupled bunch instability by the resistive wall impedance and limit the stored beam current, a bunch by bunch feedback system is implemented to suppress coupled bunch instability in the PLS-II. This paper describes the scheme and performance of the PLS-II bunch by bunch feedback system.

  19. Noninterleaved round beam lattice for light sources

    NASA Astrophysics Data System (ADS)

    Agapov, Ilya; Brinkmann, Reinhard; Keil, Joachim; Wanzenberg, Rainer

    2018-05-01

    A conceptual design and performance of a round beam lattice for synchrotron light sources based on the phase space exchange principle and the noninterleaved sextupole distribution is presented. Optics design is performed for an approximately 30 pm emittance 6 GeV machine of 2300 m circumference which combines cells with and without straight sections for the insertion devices.

  20. Monte Carlo and analytical calculations for characterization of gas bremsstrahlung in ILSF insertion devices

    NASA Astrophysics Data System (ADS)

    Salimi, E.; Rahighi, J.; Sardari, D.; Mahdavi, S. R.; Lamehi Rachti, M.

    2014-12-01

    Gas bremsstrahlung is generated in high energy electron storage rings through interaction of the electron beam with the residual gas molecules in vacuum chamber. In this paper, Monte Carlo calculation has been performed to evaluate radiation hazard due to gas bremsstrahlung in the Iranian Light Source Facility (ILSF) insertion devices. Shutter/stopper dimensions is determined and dose rate from the photoneutrons via the giant resonance photonuclear reaction which takes place inside the shutter/stopper is also obtained. Some other characteristics of gas bremsstrahlung such as photon fluence, energy spectrum, angular distribution and equivalent dose in tissue equivalent phantom have also been investigated by FLUKA Monte Carlo code.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lill, R.; Sereno, N.; Yang, B.

    The Advanced Photon Source (APS) is currently in the preliminary design phase for the multi-bend achromat (MBA) lattice upgrade. Beam stability is critical for the MBA and will require long term drift defined as beam mo-tion over a seven-day timescale to be no more than 1 mi-cron at the insertion device locations and beam angle change no more than 0.25 micro-radian. Mechanical stabil-ity of beam position monitor (BPM) pickup electrodes mounted on insertion device vacuum chambers place a fun-damental limitation on long-term beam stability for inser-tion device beamlines. We present the design and imple-mentation of prototype mechanical motion system (MMS)more » instrumentation for quantifying this type of motion specif-ically in the APS accelerator tunnel and experiment hall floor under normal operating conditions. The MMS pres-ently provides critical position information on the vacuum chamber and BPM support systems. Initial results of the R&D prototype systems have demonstrated that the cham-ber movements far exceed the long-term drift tolerance specified for the APS Upgrade MBA storage ring.« less

  2. A study of the suitability of ferrite for use in low-field insertion devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, K.; Hassenzahl, W.V.

    1995-02-01

    Most insertion devices built to date use rare-earth permanent-magnet materials, which have a high remanent field and are more expensive than many other permanent-magnet materials. Low-field insertion devices could use less-expensive, lower performance magnetic materials if they had suitable magnetic characteristics. These materials must be resistant to demagnetization during construction and operation of the insertion device, have uniform magnetization, possess low minor-axis magnetic moments, and have small minor field components on the surfaces. This paper describes an investigation to determine if ferrite possesses magnetic qualities suitable for insertion device applications. The type of ferrite investigated, MMPA Ceramic 8 from Stackpolemore » Inc., was found to be acceptable for insertion device applications.« less

  3. Novel failure mechanism and improvement for split-gate trench MOSFET with large current under unclamped inductive switch stress

    NASA Astrophysics Data System (ADS)

    Tian, Ye; Yang, Zhuo; Xu, Zhiyuan; Liu, Siyang; Sun, Weifeng; Shi, Longxing; Zhu, Yuanzheng; Ye, Peng; Zhou, Jincheng

    2018-04-01

    In this paper, a novel failure mechanism under unclamped inductive switch (UIS) for Split-Gate Trench Metal Oxide Semiconductor Field Effect Transistor (MOSFET) with large current is investigated. The device sample is tested and analyzed in detail. The simulation results demonstrate that the nonuniform potential distribution of the source poly should be responsible for the failure. Three structures are proposed and verified available to improve the device UIS ruggedness by TCAD simulation. The best one of the structures the device with source metal inserting into source poly through contacts in the field oxide is carried out and measured. The results demonstrate that the optimized structure can balance the trade-off between the UIS ruggedness and the static characteristics.

  4. Investigation of biomechanical behavior of lumbar vertebral segments with dynamic stabilization device using finite element approach

    NASA Astrophysics Data System (ADS)

    Deoghare, Ashish B.; Kashyap, Siddharth; Padole, Pramod M.

    2013-03-01

    Degenerative disc disease is a major source of lower back pain and significantly alters the biomechanics of the lumbar spine. Dynamic stabilization device is a remedial technique which uses flexible materials to stabilize the affected lumbar region while preserving the natural anatomy of the spine. The main objective of this research work is to investigate the stiffness variation of dynamic stabilization device under various loading conditions under compression, axial rotation and flexion. Three dimensional model of the two segment lumbar spine is developed using computed tomography (CT) scan images. The lumbar structure developed is analyzed in ANSYS workbench. Two types of dynamic stabilization are considered: one with stabilizing device as pedicle instrumentation and second with stabilization device inserted around the inter-vertebral disc. Analysis suggests that proper positioning of the dynamic stabilization device is of paramount significance prior to the surgery. Inserting the device in the posterior region indicates the adverse effects as it shows increase in the deformation of the inter-vertebral disc. Analysis executed by positioning stabilizing device around the inter-vertebral disc yields better result for various stiffness values under compression and other loadings. [Figure not available: see fulltext.

  5. Thermo-mechanical analysis of a user filter assembly for undulator/wiggler operations at the Advanced Photon Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nian, H.L.T.; Kuzay, T.M.; Collins, J.

    1996-12-31

    This paper reports a thermo-mechanical study of a beamline filter (user filter) for undulator/wiggler operations. It is deployed in conjunction with the current commissioning window assembly on the APS insertion device (ID) front ends. The beamline filter at the Advanced Photon Source (APS) will eventually be used in windowless operations also. Hence survival and reasonable life expectancy of the filters under intense insertion device (ID) heat flu are crucial to the beamline operations. To accommodate various user requirements, the filter is configured to be a multi-choice type and smart to allow only those filter combinations that will be safe tomore » operate with a given ring current and beamline insertion device gap. However, this paper addresses only the thermo-mechanical analysis of individual filter integrity and safety in all combinations possible. The current filter design is configured to have four filter frames in a cascade with each frame holding five filters. This allows a potential 625 total filter combinations. Thermal analysis for all of these combinations becomes a mammoth task considering the desired choices for filter materials (pyrolitic graphite and metallic filters), filter thicknesses, undulator gaps, and the beam currents. The paper addresses how this difficult task has been reduced to a reasonable effort and computational level. Results from thermo-mechanical analyses of the filter combinations are presented both in tabular and graphical format.« less

  6. The PNC-CAT insertion device beamline at the Advanced Photon Source

    NASA Astrophysics Data System (ADS)

    Heald, S. M.; Stern, E. A.; Brown, F. C.; Kim, K. H.; Barg, B.; Crozier, E. D.

    1996-09-01

    The PNC-CAT is a consortium of Pacific Northwest institutions formed to instrument a sector (number 20) at the Advanced Photon Source (APS). Research is planned in a variety of areas, with an emphasis on environmentally based problems. The insertion device beamline is based on the APS undulator A and will be optimized for producing microbeams as well as for applications requiring energy scanning capabilities. This paper describes the basic layout and some special features of the beamline. Two experimental stations are planned: one general purpose and one dedicated to MBE and surface science problems. Both tapered capillaries and Kirkpatrick-Baez optics will be used for producing microbeams, and a large optical bench is planned for the main station to allow for easy accommodation of new optics developments. Design calculations and initial capillary tests indicate that flux densities exceeding 1011 photons/sec/mm2 should be achievable. All major components are under construction or in procurement, and initial testing is planned for late 1996.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Polack, F.; Silly, M.; Chauvet, C.

    A new insertion device beamline is now operational on straight section 8 at the SOLEIL synchrotron radiation source in France. The beamline and the experimental station were developed to optimize the study of the dynamics of electronic and magnetic properties of materials. Here we present the main technical characteristics of the installation and the general principles behind them. The source is composed of two APPLE II type insertion devices. The monochromator with plane gratings and spherical mirrors is working in the energy range 40-1500 eV. It is equipped with VLS, VGD gratings to allow the user optimization of flux ormore » higher harmonics rejection. The observed resonance structures measured in gas phase enable us to determine the available energy resolution: a resolving power higher than 10000 is obtained at the Ar 2p, N 1s and Ne K-edges when using all the optical elements at full aperture. The total flux as a function of the measured photon energy and the characterization of the focal spot size complete the beamline characterization.« less

  8. Latest experiences and future plans on NSLS-II insertion devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tanabe, T.; Hidaka, Y.; Kitegi, C.

    National Synchrotron Light Source-II (NSLS-II) is the latest storage ring of 3 GeV energy at the Brookhaven National Laboratory (BNL). The horizontal emittance of the electron beam with the currently installed six damping wigglers is 0.9 nm.rad, which could be further reduced to 0.5 nm.rad with more insertion devices (IDs). With only one RF cavity the beam current is restricted to 200 mA. Five hundred mA operation is envisaged for next year with an addition of the second cavity. Six (plus two branches) beamlines have been commissioned in the initial phase of the project. In July 2015, three NIH fundedmore » beamlines called “Advanced Beamlines for Biological Investigations with X-rays” (ABBIX) will be added for operation. This paper describes the experiences of ID development, installation, and commissioning for the NSLS-II project as well as our future plans to improve the performance of the facility in terms of source development.« less

  9. Corneal seal device

    NASA Technical Reports Server (NTRS)

    Baehr, E. F. (Inventor)

    1977-01-01

    A corneal seal device is provided which, when placed in an incision in the eye, permits the insertion of a surgical tool or instrument through the device into the eye. The device includes a seal chamber which opens into a tube which is adapted to be sutured to the eye and serves as an entry passage for a tool. A sealable aperture in the chamber permits passage of the tool through the chamber into the tube and hence into the eye. The chamber includes inlet ports adapted to be connected to a regulated source of irrigation fluid which provides a safe intraocular pressure.

  10. A simple, efficient resistance soldering apparatus

    NASA Technical Reports Server (NTRS)

    Vermillion, C. M.

    1972-01-01

    Multiple resistance soldering device for attaching electric leads to multiple terminal block connectors uses power source with one terminal connected to working probe, and other terminal attached to connector carrying common pins for lead insertion. Mating of male and female connectors solders each lead to individual cup pin.

  11. Superlattice structure modeling and simulation of High Electron Mobility Transistor for improved performance

    NASA Astrophysics Data System (ADS)

    Munusami, Ravindiran; Yakkala, Bhaskar Rao; Prabhakar, Shankar

    2013-12-01

    Magnetic tunnel junction were made by inserting the magnetic materials between the source, channel and the drain of the High Electron Mobility Transistor (HEMT) to enhance the performance. Material studio software package was used to design the superlattice layers. Different cases were analyzed to optimize the performance of the device by placing the magnetic material at different positions of the device. Simulation results based on conductivity reveals that the device has a very good electron transport due to the magnetic materials and will amplify very low frequency signals.

  12. Insertion device and method for accurate and repeatable target insertion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gubeli, III, Joseph F.; Shinn, Michelle D.; Bevins, Michael E.

    The present invention discloses a device and a method for inserting and positioning a target within a free electron laser, particle accelerator, or other such device that generates or utilizes a beam of energy or particles. The system includes a three-point registration mechanism that insures angular and translational accuracy and repeatability of positioning upon multiple insertions within the same structure.

  13. Noise suppression of a dipole source by tensioned membrane with side-branch cavities

    PubMed Central

    Liu, Y.; Choy, Y. S.; Huang, L.; Cheng, L.

    2012-01-01

    Reducing the ducted-fan noise at the low frequency range remains a big technical challenge. This study presents a passive approach to directly suppress the dipole sound radiation from an axial-flow fan housed by a tensioned membrane with cavity backing. The method aims at achieving control of low frequency noise with an appreciable bandwidth. The use of the membrane not only eliminates the aerodynamic loss of flow, but also provides flexibility in controlling the range of the stopband with high insertion loss by varying its tension and mass. A three-dimensional model is presented which allows the performance of the proposed device to be explored analytically. With the proper design, this device can achieve a noise reduction of 5 dB higher than the empty expansion cavity recently proposed by Huang et al. [J. Acoust. Soc. Am. 128, 152–163 (2010)]. Through the detailed modal analysis, even in vacuo modes of the membrane vibration are found to play an important role in the suppression of sound radiation from the dipole source. Experimental validation is conducted with a loudspeaker as the dipole source and good agreement between the predicted and measured insertion loss is achieved. PMID:22978868

  14. 21 CFR 886.5420 - Contact lens inserter/remover.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Contact lens inserter/remover. 886.5420 Section 886.5420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5420 Contact lens inserter/remover...

  15. The experience of Taiwan photon source commissioning and operation

    NASA Astrophysics Data System (ADS)

    Liu, Y. C.; Chen, C. H.; Y Chen, J.; Chiu, M. S.; Chou, P. J.; Huang, C. S.; Fann, Sam; Kuo, C. C.; Y Lee, T.; Liang, C. C.; Luo, G. H.; Tsai, H. J.; Tseng, F. H.

    2017-07-01

    TPS commissioning occurred between August 2014 and March 2016. The experience of phase I (bare lattice 2014.8∼2015.3) and phase II (SRF and insertion devices 2015.9∼2016.3) commissioning will be discussed. The Taiwan Photon Source (TPS) started user operation in March 2016 and delivery of user time has reached 3,211 hours in 2016. Continuous improvements of integrated accelerator performance and future developments are described and discussed.

  16. Theory of electromagnetic insertion devices and the corresponding synchrotron radiation

    NASA Astrophysics Data System (ADS)

    Shumail, Muhammad; Tantawi, Sami G.

    2016-07-01

    Permanent magnet insertion devices (IDs), which are the main radiation generating devices in synchrotron light sources and free-electron lasers, use a time-invariant but space-periodic magnetic field to wiggle relativistic electrons for short-wavelength radiation generation. Recently, a high power microwave based undulator has also been successfully demonstrated at SLAC which promises the advantage of dynamic tunability of radiation spectrum and polarization. Such IDs employ transverse elecromagnetic fields which are periodic in both space and time to undulate the electrons. In this paper we develop a detailed theory of the principle of electromagnetic IDs from first principles for both linear and circular polarization modes. The electromagnetic equivalent definitions of undulator period (λu) and undulator deflection parameter (K ) are derived. In the inertial frame where the average momentum of the electron is zero, we obtain the figure-8-like trajectory for the linear polarization mode and the circular trajectory for the circular polarization mode. The corresponding radiation spectra and the intensity of harmonics is also calculated.

  17. Chassis unit insert tightening-extract device

    NASA Technical Reports Server (NTRS)

    Haerther, L. W.; Zimmerman, P. A. (Inventor)

    1964-01-01

    The invention relates to the insertion and extraction of rack mounted electronic units and in particular to a screw thread insert tightening and extract device, for chassis units having a collar which may be rotatably positioned manually for the insert tightening or extraction of various associated chassis units, as desired.

  18. Insertion of lithium into electrochromic devices after completion

    DOEpatents

    Berland, Brian Spencer; Lanning, Bruce Roy; Frey, Jonathan Mack; Barrett, Kathryn Suzanne; DuPont, Paul Damon; Schaller, Ronald William

    2015-12-22

    The present disclosure describes methods of inserting lithium into an electrochromic device after completion. In the disclosed methods, an ideal amount of lithium can be added post-fabrication to maximize or tailor the free lithium ion density of a layer or the coloration range of a device. Embodiments are directed towards a method to insert lithium into the main device layers of an electrochromic device as a post-processing step after the device has been manufactured. In an embodiment, the methods described are designed to maximize the coloration range while compensating for blind charge loss.

  19. Solid state electrochromic light modulator

    DOEpatents

    Cogan, Stuart F.; Rauh, R. David

    1993-01-01

    An all solid-state variable transmission electrochromic device has a source of charge compensating ions. An inorganic oxide counterelectrode film which on reduction with the accompanying insertion of the charge compensating ions increases its transmission of light of predetermined wavelength is separated from a primary electrochromic film which on reduction with the accompanying insertion of the charge compensating ions decreases its transmission of light of predetermined wavelength by an insulating electrolyte film that transports the charge compensating ions. First and second electrodes are contiguous with the inorganic oxide counter electrode film and the primary electrochromic film, respectively, and separated by the three films.

  20. Solid state electrochromic light modulator

    DOEpatents

    Cogan, Stuart F.; Rauh, R. David

    1993-12-07

    An all solid-state variable transmission electrochromic device has a source of charge compensating ions. An inorganic oxide counterelectrode film which on reduction with the accompanying insertion of the charge compensating ions increases its transmission of light of predetermined wavelength is separated from a primary electrochromic film which on reduction with the accompanying insertion of the charge compensating ions decreases its transmission of light of predetermined wavelength by an insulating electrolyte film that transports the charge compensating ions. First and second electrodes are contiguous with the inorganic oxide counter electrode film and the primary electrochromic film, respectively, and separated by the three films.

  1. Solid state electrochromic light modulator

    DOEpatents

    Cogan, Stuart F.; Rauh, R. David

    1990-01-01

    An all solid-state variable transmission electrochromic device has a source of charge compensating ions. An inorganic oxide counterelectrode film which on reduction with the accompanying insertion of the charge compensating ions increases its transmission of light of predetermined wavelength is separated from a primary electrochromic film which on reduction with the accompanying insertion of the charge compensating ions decreases its transmission of light of predetermined wavelength by an insulating electrolyte film that transports the charge compensating ions. First and second electrodes are contiguous with the inorganic oxide counter electrode film and the primary electrochromic film, respectively, and separated by the three films.

  2. Solid state electrochromic light modulator

    DOEpatents

    Cogan, S.F.; Rauh, R.D.

    1990-07-03

    An all solid-state variable transmission electrochromic device has a source of charge compensating ions. An inorganic oxide counter electrode film which on reduction with the accompanying insertion of the charge compensating ions increases its transmission of light of predetermined wavelength is separated from a primary electrochromic film which on reduction with the accompanying insertion of the charge compensating ions decreases its transmission of light of predetermined wavelength by an insulating electrolyte film that transports the charge compensating ions. First and second electrodes are contiguous with the inorganic oxide counter electrode film and the primary electrochromic film, respectively, and separated by the three films. 4 figs.

  3. Supraglottic Airway Devices: the Search for the Best Insertion Technique or the Time to Change Our Point of View?

    PubMed

    Sorbello, Massimiliano; Petrini, Flavia

    2017-04-01

    In the crowded world of supraglottic airway devices (SADs), many papers compare the easiness of insertion based on the different endpoints of an operator's satisfaction: first pass success, ventilation effectiveness, complications and morbidity. Proseal LMA ™ (Laryngeal Mask Airway, Teleflex Medical, Dublin, Ireland) has been extensively studied because on one hand it has a steeper learning curve and more complex insertion when compared with other SADs and on the other hand many alternative techniques are available to facilitate insertion. This research is part of a larger body of studies exploring the issue that some devices are more difficult to insert because of many features related to sizing, constructive material, airway conduit and cuff design, performance and last but not least experience. Nevertheless, the biggest question might be the search for a systematic categorization of insertion difficulty features and identification of criteria allowing the choice for the best device and consequently for the best insertion technique. Given that, as a result of many intrinsic characteristics of the device we are using, insertion might become the secondary issue to be considered only after we clearly identify what makes it difficult, and to be counterbalanced on the results we expect from the device, performance we can achieve and degree of airway protection it could grant. The aim of this narrative review is to consider which factors might affect or condition SAD insertion difficulty and to try identifying some criteria addressing physicians pertaining to the use of SADs in clinical practice.

  4. Widgets to the Rescue

    ERIC Educational Resources Information Center

    Kroski, Ellyssa

    2008-01-01

    A widget displays Web content from external sources and can be embedded into a blog, social network, or other Web page, or downloaded to one's desktop. With widgets--sometimes referred to as gadgets--one can insert video into a blog post, display slideshows on MySpace, get the weather delivered to his mobile device, drag-and-drop his Netflix queue…

  5. Elliptically polarizing adjustable phase insertion device

    DOEpatents

    Carr, Roger

    1995-01-01

    An insertion device for extracting polarized electromagnetic energy from a beam of particles is disclosed. The insertion device includes four linear arrays of magnets which are aligned with the particle beam. The magnetic field strength to which the particles are subjected is adjusted by altering the relative alignment of the arrays in a direction parallel to that of the particle beam. Both the energy and polarization of the extracted energy may be varied by moving the relevant arrays parallel to the beam direction. The present invention requires a substantially simpler and more economical superstructure than insertion devices in which the magnetic field strength is altered by changing the gap between arrays of magnets.

  6. Comparing performance of mothers using simplified mid-upper arm circumference (MUAC) classification devices with an improved MUAC insertion tape in Isiolo County, Kenya.

    PubMed

    Grant, Angeline; Njiru, James; Okoth, Edgar; Awino, Imelda; Briend, André; Murage, Samuel; Abdirahman, Saida; Myatt, Mark

    2018-01-01

    A novel approach for improving community case-detection of acute malnutrition involves mothers/caregivers screening their children for acute malnutrition using a mid-upper arm circumference (MUAC) insertion tape. The objective of this study was to test three simple MUAC classification devices to determine whether they improved the sensitivity of mothers/caregivers at detecting acute malnutrition. Prospective, non-randomised, partially-blinded, clinical diagnostic trial describing and comparing the performance of three "Click-MUAC" devices and a MUAC insertion tape. The study took place in twenty-one health facilities providing integrated management of acute malnutrition (IMAM) services in Isiolo County, Kenya. Mothers/caregivers classified their child ( n =1040), aged 6-59 months, using the "Click-MUAC" devices and a MUAC insertion tape. These classifications were compared to a "gold standard" classification (the mean of three measurements taken by a research assistant using the MUAC insertion tape). The sensitivity of mother/caregiver classifications was high for all devices (>93% for severe acute malnutrition (SAM), defined by MUAC < 115 mm, and > 90% for global acute malnutrition (GAM), defined by MUAC < 125 mm). Mother/caregiver sensitivity for SAM and GAM classification was higher using the MUAC insertion tape (100% sensitivity for SAM and 99% sensitivity for GAM) than using "Click-MUAC" devices. Younden's J for SAM classification, and sensitivity for GAM classification, were significantly higher for the MUAC insertion tape (99% and 99% respectively). Specificity was high for all devices (>96%) with no significant difference between the "Click-MUAC" devices and the MUAC insertion tape. The results of this study indicate that, although the "Click-MUAC" devices performed well, the MUAC insertion tape performed best. The results for sensitivity are higher than found in previous studies. The high sensitivity for both SAM and GAM classification by mothers/caregivers with the MUAC insertion tape could be due to the use of an improved MUAC tape design which has a number of new design features. The one-on-one demonstration provided to mothers/caregivers on the use of the devices may also have helped improve sensitivity. The results of this study provide evidence that mothers/caregivers can perform sensitive and specific classifications of their child's nutritional status using MUAC. Clinical trials registration number: NCT02833740.

  7. Intracranial surgical operative apparatus

    NASA Technical Reports Server (NTRS)

    Sheldon, Charles H. (Inventor); Frazer, Robert E. (Inventor); Lutes, Harold R. (Inventor)

    1983-01-01

    Apparatus for operating on the brain with minimal disturbances thereto, including a bullet-shaped expandable device with an end that can be closed for insertion through a small hole in the brain. The device can be expanded after insertion to leave an air pocket through which to extend viewing and cutting devices which enable operation on tumors or the like that lie at the end of the expanded device. A set of probes of varying diameters are also provided, to progressively enlarge a passage leading to the tumor, prior to inserting the expandable device.

  8. A novel compensation method of insertion losses for wavelet inverse-transform processors using surface acoustic wave devices.

    PubMed

    Lu, Wenke; Zhu, Changchun

    2011-11-01

    The objective of this research was to investigate the possibility of compensating for the insertion losses of the wavelet inverse-transform processors using SAW devices. The motivation for this work was prompted by the processors which are of large insertion losses. In this paper, the insertion losses are the key problem of the wavelet inverse-transform processors using SAW devices. A novel compensation method of the insertion losses is achieved in this study. When the output ends of the wavelet inverse-transform processors are respectively connected to the amplifiers, their insertion losses can be compensated for. The bandwidths of the amplifiers and their adjustment method are also given in this paper. © 2011 American Institute of Physics

  9. Micro-Fluidic Device for Drug Delivery

    NASA Technical Reports Server (NTRS)

    Beebe, David J. (Inventor); Eddington, David T. (Inventor); MacDonald, Michael J. (Inventor); Mensing, Glennys A. (Inventor)

    2014-01-01

    A microfluidic device is provided for delivering a drug to an individual. The microfluidic device includes a body that defines a reservoir for receiving the drug therein. A valve interconnects the reservoir to an output needle that is insertable into the skin of an individual. A pressure source urges the drug from the reservoir toward the needle. The valve is movable between a closed position preventing the flow of the drug from the reservoir to the output needle and an open position allowing for the flow of the drug from the reservoir to the output needle in response to a predetermined condition in the physiological fluids of the individual.

  10. Microfluidic device for drug delivery

    NASA Technical Reports Server (NTRS)

    MacDonald, Michael J. (Inventor); Eddington, David T. (Inventor); Beebe, David J. (Inventor); Mensing, Glennys A. (Inventor)

    2010-01-01

    A microfluidic device is provided for delivering a drug to an individual. The microfluidic device includes a body that defines a reservoir for receiving the drug therein. A valve interconnects the reservoir to an output needle that is insertable into the skin of an individual. A pressure source urges the drug from the reservoir toward the needle. The valve is movable between a closed position preventing the flow of the drug from the reservoir to the output needle and an open position allowing for the flow of the drug from the reservoir to the output needle in response to a predetermined condition in the physiological fluids of the individual.

  11. Neutral source and particle balance in the HSX edge

    NASA Astrophysics Data System (ADS)

    Stephey, Laurie; Kumar, Santhosh; Bader, Aaron; Akerson, Adrian; Schmitz, Oliver; Anderson, David; A, Simon; Talmadge, Joseph; Hegna, Chris

    2015-11-01

    The ability to control the neutral particle and impurity source in fusion devices is critical to obtaining high purity, high confinement plasmas. The neutral particle source defines the edge density gradients and plasma flows. To understand the relationship between the neutral particle source, plasma density gradients and plasma edge and core transport in HSX, a single reservoir particle balance is being used to provide a complete particle inventory. Detailed spectroscopic measurements of hydrogen and helium emission have yielded neutral and plasma profiles and ionization length estimations. The plasma puff source rate has been directly measured. To determine the recycling source rate, two specially designed limiters will be inserted to intercept 99% of the field lines, resulting in a well-defined LCFS and plasma interaction zone. Single limiter insertion resulted in a 50% reduction in global line emission, implying a reduction in wall recycling. Future camera and probe measurements will provide a recycling source rate. HSX neutral physics is also being investigated using EMC3-EIRENE. All results are discussed along with complementary plans for the Wendelstein 7-X startup phase. This work supported by US DOE Grant DE-FG02-93ER54222 and DE-SC0006103.

  12. Fiber Bragg grating based arterial localization device

    NASA Astrophysics Data System (ADS)

    Ho, Siu Chun Michael; Li, Weijie; Razavi, Mehdi; Song, Gangbing

    2017-06-01

    A critical first step to many surgical procedures is locating and gaining access to a patients vascular system. Vascular access allows the deployment of other surgical instruments and also the monitoring of many physiological parameters. Current methods to locate blood vessels are predominantly based on the landmark technique coupled with ultrasound, fluoroscopy, or Doppler. However, even with experience and technological assistance, locating the required blood vessel is not always an easy task, especially with patients that present atypical anatomy or suffer from conditions such as weak pulsation or obesity that make vascular localization difficult. With recent advances in fiber optic sensors, there is an opportunity to develop a new tool that can make vascular localization safer and easier. In this work, the authors present a new fiber Bragg grating (FBG) based vascular access device that specializes in arterial localization. The device estimates the location towards a local artery based on the bending of a needle inserted near the tissue surrounding the artery. Experimental results obtained from an artificial circulatory loop and a mock artery show the device works best for lower angles of needle insertion and can provide an approximately 40° range of estimation towards the location of a pulsating source (e.g. an artery).

  13. Elliptically polarizing adjustable phase insertion device

    DOEpatents

    Carr, R.

    1995-01-17

    An insertion device for extracting polarized electromagnetic energy from a beam of particles is disclosed. The insertion device includes four linear arrays of magnets which are aligned with the particle beam. The magnetic field strength to which the particles are subjected is adjusted by altering the relative alignment of the arrays in a direction parallel to that of the particle beam. Both the energy and polarization of the extracted energy may be varied by moving the relevant arrays parallel to the beam direction. The present invention requires a substantially simpler and more economical superstructure than insertion devices in which the magnetic field strength is altered by changing the gap between arrays of magnets. 3 figures.

  14. Fabrication of robust tooling for mass production of polymeric microfluidic devices

    NASA Astrophysics Data System (ADS)

    Fu, G.; Tor, S. B.; Loh, N. H.; Hardt, D. E.

    2010-08-01

    Polymer microfluidic devices are gaining popularity for bio-applications. In both commonly used methods for the fabrication of polymer microfluidic devices, i.e. injection molding and hot-embossing, the quality of a mold insert is of high importance. Micro powder injection molding (μPIM) provides a suitable option for metal mold insert fabrication. In this paper, two mold inserts with micro-features of different patterns and sizes were produced using 316L stainless steel powder and an in-house binder system. The mold inserts were successfully used to produce cyclic olefin copolymer (COC, trade name TOPAS) micromixer plates with micro-channels of widths 100 µm and 50 µm. Compared with CNC-machined hot work steel mold inserts, the quality of the micro-channels is better as far as geometrical quality and dimensional tolerance are concerned. However, surface finish and flatness of the μPIM mold inserts are inferior to those of CNC-machined mold inserts.

  15. Theory of electromagnetic insertion devices and the corresponding synchrotron radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shumail, Muhammad; Tantawi, Sami G.

    Permanent magnet insertion devices (IDs), which are the main radiation generating devices in synchrotron light sources and free-electron lasers, use a time-invariant but space-periodic magnetic field to wiggle relativistic electrons for short-wavelength radiation generation. Recently, a high power microwave based undulator has also been successfully demonstrated at SLAC which promises the advantage of dynamic tunability of radiation spectrum and polarization. Such IDs employ transverse elecromagnetic fields which are periodic in both space and time to undulate the electrons. In this paper we develop a detailed theory of the principle of electromagnetic IDs from first principles for both linear and circularmore » polarization modes. The electromagnetic equivalent definitions of undulator period (λ u) and undulator deflection parameter (K) are derived. In the inertial frame where the average momentum of the electron is zero, we obtain the figure-8-like trajectory for the linear polarization mode and the circular trajectory for the circular polarization mode. As a result, the corresponding radiation spectra and the intensity of harmonics is also calculated.« less

  16. Theory of electromagnetic insertion devices and the corresponding synchrotron radiation

    DOE PAGES

    Shumail, Muhammad; Tantawi, Sami G.

    2016-07-27

    Permanent magnet insertion devices (IDs), which are the main radiation generating devices in synchrotron light sources and free-electron lasers, use a time-invariant but space-periodic magnetic field to wiggle relativistic electrons for short-wavelength radiation generation. Recently, a high power microwave based undulator has also been successfully demonstrated at SLAC which promises the advantage of dynamic tunability of radiation spectrum and polarization. Such IDs employ transverse elecromagnetic fields which are periodic in both space and time to undulate the electrons. In this paper we develop a detailed theory of the principle of electromagnetic IDs from first principles for both linear and circularmore » polarization modes. The electromagnetic equivalent definitions of undulator period (λ u) and undulator deflection parameter (K) are derived. In the inertial frame where the average momentum of the electron is zero, we obtain the figure-8-like trajectory for the linear polarization mode and the circular trajectory for the circular polarization mode. As a result, the corresponding radiation spectra and the intensity of harmonics is also calculated.« less

  17. Conceptual design of front ends for the advanced photon source multi-bend achromats upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jaski, Y., E-mail: jaskiy@aps.anl.gov; Westferro, F., E-mail: westferr@aps.anl.gov; Lee, S. H., E-mail: shlee@aps.anl.gov

    2016-07-27

    The proposed Advanced Photon Source (APS) upgrade from a double-bend achromats (DBA) to multi-bend achromats (MBA) lattice with ring energy change from 7 GeV to 6 GeV and beam current from 100 mA to 200 mA poses new challenges for front ends. All front ends must be upgraded to fulfill the following requirements: 1) handle the high heat load from two insertion devices in either inline or canted configuration, 2) include a clearing magnet in the front end to deflect and dump any electrons in case the electrons escape from the storage ring during swap-out injection with the safety shuttersmore » open, 3) incorporate the next generation x-ray beam position monitors (XBPMs) into the front end to meet the new stringent beam stability requirements. This paper presents the evaluation of the existing APS front ends and standardizes the insertion device (ID) front ends into two types: one for the single beam and one for the canted beams. The conceptual design of high heat load front end (HHLFE) and canted undulator front end (CUFE) for APS MBA upgrade is presented.« less

  18. Conceptual Design of Front Ends for the Advanced Photon Source Multi-bend Achromats Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jaski, Y.; Westferro, F.; Lee, S. H.

    2016-07-27

    The proposed Advanced Photon Source (APS) upgrade from a double-bend achromats (DBA) to multi-bend achromats (MBA) lattice with ring energy change from 7 GeV to 6 GeV and beam current from 100 mA to 200 mA poses new challenges for front ends. All front ends must be upgraded to fulfill the following requirements: 1) handle the high heat load from two insertion devices in either inline or canted configuration, 2) include a clearing magnet in the front end to deflect and dump any electrons in case the electrons escape from the storage ring during swap-out injection with the safety shuttersmore » open, 3) incorporate the next generation x-ray beam position monitors (XBPMs) into the front end to meet the new stringent beam stability requirements. This paper presents the evaluation of the existing APS front ends and standardizes the insertion device (ID) front ends into two types: one for the single beam and one for the canted beams. The conceptual design of high heat load front end (HHLFE) and canted undulator front end (CUFE) for APS MBA upgrade is presented.« less

  19. Immediate postpartum levonorgestrel intrauterine device insertion and breast-feeding outcomes: a noninferiority randomized controlled trial.

    PubMed

    Turok, David K; Leeman, Lawrence; Sanders, Jessica N; Thaxton, Lauren; Eggebroten, Jennifer L; Yonke, Nicole; Bullock, Holly; Singh, Rameet; Gawron, Lori M; Espey, Eve

    2017-12-01

    Immediate postpartum levonorgestrel intrauterine device insertion is increasing in frequency in the United States, but few studies have investigated the effect of early placement on breast-feeding outcomes. This study examined the effect of immediate vs delayed postpartum levonorgestrel intrauterine device insertion on breast-feeding outcomes. We conducted this noninferiority randomized controlled trial at the University of Utah and the University of New Mexico Health Sciences Centers from February 2014 through March 2016. Eligible women were pregnant and planned to breast-feed, spoke English or Spanish, were aged 18-40 years, and desired a levonorgestrel intrauterine device. Enrolled women were randomized 1:1 to immediate postpartum insertion or delayed insertion at 4-12 weeks' postpartum. Prespecified exclusion criteria included delivery <37.0 weeks' gestational age, chorioamnionitis, postpartum hemorrhage, contraindications to levonorgestrel intrauterine device insertion, and medical complications of pregnancy that could affect breast-feeding. We conducted per-protocol analysis as the primary approach, as it is considered the standard for noninferiority studies; we also report the alternative intent-to-treat analysis. We powered the study for the primary outcome, breast-feeding continuation at 8 weeks, to detect a 15% noninferiority margin between groups, requiring 132 participants in each arm. The secondary study outcome, time to lactogenesis, used a validated measure, and was analyzed by survival analysis and log rank test. We followed up participants for ongoing data collection for 6 months. Only the data analysis team was blinded to the intervention. We met the enrollment target with 319 participants, but lost 34 prior to randomization and excluded an additional 26 for medical complications prior to delivery. The final analytic sample included 132 in the immediate group and 127 in the delayed group. Report of any breast-feeding at 8 weeks in the immediate group (79%; 95% confidence interval, 70-86%) was noninferior to that of the delayed group (84%; 95% confidence interval, 76-91%). The 5% difference in breast-feeding continuation at 8 weeks between the groups fell within the noninferiority margin (95% confidence interval, -5.6 to 15%). Time to lactogenesis (mean ± SD) in the immediate group, 65.3 ± 25.7 hours, was noninferior to that of the delayed group, 63.6 ± 21.6 hours. The mean difference between groups was 1.7 hours (95% confidence interval, -4.8 to 8.2 hours), noninferior by log-rank test. A total of 24 intrauterine device expulsions occurred in the immediate group compared to 2 in the delayed group (19% vs 2%, P < .001), consistent with the known higher expulsion rate with immediate vs delayed postpartum intrauterine device insertion. No intrauterine device perforations occurred in either group. Our results of noninferior breast-feeding outcomes between women with immediate and delayed postpartum levonorgestrel intrauterine device insertion suggest that immediate postpartum intrauterine device insertion is an acceptable option for women planning to breast-feed and use the levonorgestrel intrauterine device. Expulsion rates are higher with immediate postpartum levonorgestrel intrauterine device insertion compared to delayed insertion, but this disadvantage may be outweighed by the advantages of immediate initiation of contraception. Providers should offer immediate postpartum intrauterine device insertion to breast-feeding women planning to use the levonorgestrel intrauterine device. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Development of CMTD (Curved Multi-Tubed Device) -system III and its application to the needle-insertion for liver.

    PubMed

    Furusho, Junji; Kobayashi, Hiroshi; Kikuchi, Takehito; Yamamoto, Tatsuro; Tanaka, Hidekazu; Terayama, Motokazu; Monden, Morito

    2008-01-01

    The purpose of this study is to realize the mechanically-controllable needle-insertion system using the CMTD (Curved Multi-Tube Device) which was developed by Furusho Laboratory. A CMTD, was developed for minimally-invasive surgery and needle insertion. And we use ultrasonograph as a sensing device to detect the position of bible duct or tumor and the orientation and position of the needle which is inserted into liver. This system makes safe minimally-invasive surgery possible, because all complex mechanisms are arranged outside of the body.

  1. Optical Device for Converting a Laser Beam into Two Co-aligned but Oppositely Directed Beams

    NASA Technical Reports Server (NTRS)

    Jennings, Donald

    2013-01-01

    Optical systems consisting of a series of optical elements require alignment from the input end to the output end. The optical elements can be mirrors, lenses, sources, detectors, or other devices. Complex optical systems are often difficult to align from end-to-end because the alignment beam must be inserted at one end in order for the beam to traverse the entire optical path to the other end. The ends of the optical train may not be easily accessible to the alignment beam. Typically, when a series of optical elements is to be aligned, an alignment laser beam is inserted into the optical path with a pick-off mirror at one end of the series of elements. But it may be impossible to insert the beam at an end-point. It can be difficult to locate the pick-off mirror at the desired position because there is not enough space, there is no mounting surface, or the location is occupied by a source, detector, or other component. Alternatively, the laser beam might be inserted at an intermediate location (not at an end-point) and sent, first in one direction and then the other, to the opposite ends of the optical system for alignment. However, in this case, alignment must be performed in two directions and extra effort is required to co-align the two beams to make them parallel and coincident, i.e., to follow the same path as an end-to-end beam. An optical device has been developed that accepts a laser beam as input and produces two co-aligned, but counter-propagating beams. In contrast to a conventional alignment laser placed at one end of the optical path, this invention can be placed at a convenient position within the optical train and aligned to send its two beams simultaneously along precisely opposite paths that, taken together, trace out exactly the same path as the conventional alignment laser. This invention allows the user the freedom to choose locations within the optical train for placement of the alignment beam. It is also self-aligned by design and requires almost no adjustment.

  2. Study of low insertion loss and miniaturization wavelet transform and inverse transform processor using SAW devices.

    PubMed

    Jiang, Hua; Lu, Wenke; Zhang, Guoan

    2013-07-01

    In this paper, we propose a low insertion loss and miniaturization wavelet transform and inverse transform processor using surface acoustic wave (SAW) devices. The new SAW wavelet transform devices (WTDs) use the structure with two electrode-widths-controlled (EWC) single phase unidirectional transducers (SPUDT-SPUDT). This structure consists of the input withdrawal weighting interdigital transducer (IDT) and the output overlap weighting IDT. Three experimental devices for different scales 2(-1), 2(-2), and 2(-3) are designed and measured. The minimum insertion loss of the three devices reaches 5.49dB, 4.81dB, and 5.38dB respectively which are lower than the early results. Both the electrode width and the number of electrode pairs are reduced, thus making the three devices much smaller than the early devices. Therefore, the method described in this paper is suitable for implementing an arbitrary multi-scale low insertion loss and miniaturization wavelet transform and inverse transform processor using SAW devices. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Numerical investigations of MRI RF field induced heating for external fixation devices

    PubMed Central

    2013-01-01

    Background The magnetic resonance imaging (MRI) radio frequency (RF) field induced heating on external fixation devices can be very high in the vicinity of device screws. Such induced RF heating is related to device constructs, device placements, as well as the device insertion depth into human subjects. In this study, computational modeling is performed to determine factors associated with such induced heating. Methods Numerical modeling, based on the finite-difference time-domain (FDTD) method, is used to evaluate the temperature rises near external device screw tips inside the ASTM phantom for both 1.5-T and 3-T MRI systems. The modeling approach consists of 1) the development of RF coils for 1.5-T and 3-T, 2) the electromagnetic simulations of energy deposition near the screw tips of external fixation devices, and 3) the thermal simulations of temperature rises near the tips of these devices. Results It is found that changing insertion depth and screw spacing could largely affect the heating of these devices. In 1.5-T MRI system, smaller insertion depth and larger pin spacing will lead to higher temperature rise. However, for 3-T MRI system, the relation is not very clear when insertion depth is larger than 5 cm or when pin spacing became larger than 20 cm. The effect of connection bar material on device heating is also studied and the heating mechanism of the device is analysed. Conclusions Numerical simulation is used to study RF heating for external fixation devices in both 1.5-T and 3-T MRI coils. Typically, shallower insertion depth and larger pin spacing with conductive bar lead to higher RF heating. The heating mechanism is explained using induced current along the device and power decay inside ASTM phantom. PMID:23394173

  4. 418th Brookhaven Lecture

    ScienceCinema

    Timur Shaftan

    2017-12-09

    The NSLS-II project will establish a third-generation light source at Brookhaven Lab, increasing beam-line brightness by 10,000. Achieving and maintaining this will involve tightly focusing the electron beam, providing the most efficient insertion devices, and achieving and maintaining a high electron current. In this talk, the various sub-systems of NSLS-II will be reviewed, and the requirements and key elements of their design will be discussed. In addition, the a small prototype of a light source of a different kind that was developed by the NSLS will also be discussed.

  5. THERMO-ELECTRIC GENERATOR

    DOEpatents

    Jordan, K.C.

    1958-07-22

    The conversion of heat energy into electrical energy by a small compact device is descrtbed. Where the heat energy is supplied by a radioactive material and thermopIIes convert the heat to electrical energy. The particular battery construction includes two insulating discs with conductive rods disposed between them to form a circular cage. In the center of the cage is disposed a cup in which the sealed radioactive source is located. Each thermopile is formed by connecting wires from two adjacent rods to a potnt on an annular ring fastened to the outside of the cup, the ring having insulation on its surface to prevent electrica1 contact with the thermopiles. One advantage of this battery construction is that the radioactive source may be inserted after the device is fabricated, reducing the radiation hazard to personnel assembling the battery.

  6. Cholorhexidine, octenidine or povidone iodine for catheter related infections: A randomized controlled trial.

    PubMed

    Bilir, Ayten; Yelken, Birgül; Erkan, Ayse

    2013-06-01

    Protection of the catheter site by antimicrobial agents is one of the most important factors in the prevention of infection. Povidone iodine and chlorhexidine gluconate are the most common used agents for dressing. The purpose of this study was to compare the effects of povidone iodine, chlorhexidine gluconate and octenidine hydrochloride in preventing catheter related infections. Patients were randomized to receive; 4% chlorhexidine gluconate, 10% povidone iodine or octenidine hydrochlorodine for cutaneous antisepsis. Cultures were taken at the site surrounding catheter insertion and at the catheter hub after removal to help identify the source of microorganisms. Catheter related sepsis was 10.5% in the povidone iodine and octenidine hydrochlorodine groups. Catheter related colonization was 26.3% in povidone iodine group and 21.5% in octenidine hydrochlorodine group. 4% chlorhexidine or octenidine hydrochlorodine for cutaneous disinfection before insertion of an intravascular device and for post-insertion site care can reduce the catheter related colonization.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    M Severson; M Bissen; M Fisher

    SRC has recently commissioned a new Varied Line-Spacing Plane Grating Monochromator (VLS-PGM) utilizing as its source a 1 m long APPLE II insertion device in short-straight-section 9 of the Aladdin storage ring. The insertion device reliably delivers horizontal, vertical, and right and left circularly polarized light to the beamline. Measurements from an in situ polarimeter can be used for undulator corrections to compensate for depolarizing effects of the beamline. The beamline has only three optical elements and covers the energy range from 11.1 to 270 eV using two varied line-spacing gratings. A plane mirror rotates to illuminate the gratings atmore » the correct angle to cancel the defocus term at all photon energies. An exit slit and elliptical-toroid refocusing mirror complete the beamline. Using a 50 {mu}m exit slit, the beamline provides moderate to high resolution, with measured flux in the mid 10{sup 12} (photons/s/200 mA) range, and a spot size of 400 {mu}m horizontal by 30 {mu}m vertical.« less

  8. Insertion devices for Doris III

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pfluger, J.; Heintze, G.; Baran, W.

    1992-01-01

    In this paper the mechanical and magnetic layout of the first three insertion devices for DORIS III, an upgraded reconstruction of DORIS II, is described and results of the magnetic characterization are given as well.

  9. Evaluation of a new pediatric intraosseous needle insertion device for low-resource settings.

    PubMed

    Kalechstein, Sara; Permual, Ahiliyia; Cameron, Blair M; Pemberton, Julia; Hollaar, Gwen; Duffy, Deirdre; Cameron, Brian H

    2012-05-01

    The Near Needle Holder (NNH) (Near Manufacturing, Camrose, Alberta, Canada) is a reusable tool to introduce a standard hollow needle for pediatric intraosseous (IO) infusion. We compared the NNH to the Cook Dieckmann (Cook Critical Care, Bloomington, IN) manual IO needle in a simulation setting. Study subjects were 32 physicians, nurses, and medical students participating in a trauma course in Guyana. After watching a training video and practicing under supervision, subjects were observed inserting each device into a pediatric leg model using a randomized crossover design. Outcome measures were time to successful insertion, technical complications, ease of use, and safety of each device. The mean time for IO insertion (32 ± 13 seconds) was similar for both devices (P = .92). Subjects rated the NNH device equivalent in ease of use to the Cook IO needle but slightly lower in perceived safety to the user. After training, all subjects successfully inserted the NNH IO device in a simulation environment, and most rated it as easy to use and safe. The NNH is a significant advance because IO needles are often not available in emergency departments in developing countries. Further studies are needed to evaluate clinical effectiveness of the NNH. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Intrauterine devices and risk of uterine perforation: current perspectives

    PubMed Central

    Rowlands, Sam; Oloto, Emeka; Horwell, David H

    2016-01-01

    Uterine perforation is an uncommon complication of intrauterine device insertion, with an incidence of one in 1,000 insertions. Perforation may be complete, with the device totally in the abdominal cavity, or partial, with the device to varying degrees within the uterine wall. Some studies show a positive association between lactation and perforation, but a causal relationship has not been established. Very rarely, a device may perforate into bowel or the urinary tract. Perforated intrauterine devices can generally be removed successfully at laparoscopy. PMID:29386934

  11. Assessment of the speed and ease of insertion of three supraglottic airway devices by paramedics: a manikin study.

    PubMed

    Castle, Nick; Owen, Robert; Hann, Mark; Naidoo, Raveen; Reeves, David

    2010-11-01

    Control of the airway is a priority during cardiopulmonary resuscitation and/or following a failed intubation attempt. Supraglottic airway devices provide more effective airway management than bag-valve-mask-ventilation (BVMV) and can be effectively used by non-anaesthetists. 36 paramedic students were timed to ascertain how long it took them to place an Igel, laryngeal mask airway (LMA) or laryngeal tube airway (LTA) into a manikin. Following insertion, students were interviewed to see which device they preferred and why. The Igel was consistently the fastest airway device, taking a mean of 12.3 s (95% CI 11.5 to 13.1) to insert, the LTA took a mean time of 22.4 s (95% CI 20.3 to 24.5) and the LMA 33.8 s (95% CI 30.9 to 36.7). 63% of students would choose the Igel as their preferred intermediate airway device, stating ease of use and speed of insertion as the primary reasons. The ease and speed at which a supraglottic airway can be inserted means that it is a viable alternative to the use of the BVMV.

  12. Interrogation of electrical connector faults using miniaturized UWB sources

    NASA Astrophysics Data System (ADS)

    Tokgöz, Çaǧata; Dardona, Sameh

    2017-01-01

    A diagnostic method for the detection, identification, and characterization of precursors of faults due to partial insertion of pin-socket contacts within electrical connectors commonly used in avionics systems is presented. It is demonstrated that a miniaturized ultrawideband (UWB) source and a minispectrum analyzer can be employed to measure resonant frequency shifts in connector S parameters as a small and low-cost alternative to a large and expensive network analyzer. The transfer function of an electrical connector is represented as a ratio of the spectra measured using the spectrum analyzer with and without the connector. Alternatively, the transfer function is derived in terms of the connector S parameters and the reflection coefficients at both ports of the connector. The transfer function data obtained using this derivation agreed well with its representation as a measured spectral ratio. The derivation enabled the extraction of the connector S parameters from the measured transfer function data as a function of the insertion depth of a pin-socket contact within the connector. In comparison with the S parameters measured directly using a network analyzer at multiple insertion depths, the S parameters extracted from the measured transfer function showed consistent and reliable representation of the electrical connector fault. The results demonstrate the potential of integrating a low-cost miniaturized UWB device into a connector harness for real-time detection of precursors to partially inserted connector faults.

  13. Advanced Photon Source accelerator ultrahigh vacuum guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, C.; Noonan, J.

    1994-03-01

    In this document the authors summarize the following: (1) an overview of basic concepts of ultrahigh vacuum needed for the APS project, (2) a description of vacuum design and calculations for major parts of APS, including linac, linac waveguide, low energy undulator test line, positron accumulator ring (PAR), booster synchrotron ring, storage ring, and insertion devices, and (3) cleaning procedures of ultrahigh vacuum (UHV) components presently used at APS.

  14. Double emulsions from a capillary array injection microfluidic device.

    PubMed

    Shang, Luoran; Cheng, Yao; Wang, Jie; Ding, Haibo; Rong, Fei; Zhao, Yuanjin; Gu, Zhongze

    2014-09-21

    A facile microfluidic device was developed by inserting an annular capillary array into a collection channel for single-step emulsification of double emulsions. By inserting multiple inner-phase solutions into the capillary array, multicomponent double emulsions or microcapsules with inner droplets of different content could also be obtained from the device.

  15. Beamline Insertions Manager at Jefferson Lab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Michael C.

    2015-09-01

    The beam viewer system at Jefferson Lab provides operators and beam physicists with qualitative and quantitative information on the transverse electron beam properties. There are over 140 beam viewers installed on the 12 GeV CEBAF accelerator. This paper describes an upgrade consisting of replacing the EPICS-based system tasked with managing all viewers with a mixed system utilizing EPICS and high-level software. Most devices, particularly the beam viewers, cannot be safely inserted into the beam line during high-current beam operations. Software is partly responsible for protecting the machine from untimely insertions. The multiplicity of beam-blocking and beam-vulnerable devices motivates us tomore » try a data-driven approach. The beamline insertions application components are centrally managed and configured through an object-oriented software framework created for this purpose. A rules-based engine tracks the configuration and status of every device, along with the beam status of the machine segment containing the device. The application uses this information to decide on which device actions are allowed at any given time.« less

  16. Best practices to minimize risk of infection with intrauterine device insertion.

    PubMed

    Caddy, Sheila; Yudin, Mark H; Hakim, Julie; Money, Deborah M

    2014-03-01

    Intrauterine devices provide an extremely effective, long-term form of contraception that has the benefit of being reversible. Historically, the use of certain intrauterine devices was associated with increased risk of pelvic inflammatory disease. More recent evidence suggests that newer devices do not carry the same threat; however, certain risk factors can increase the possibility of infection. To review the risk of infection with the insertion of intrauterine devices and recommend strategies to prevent infection. The outcomes considered were the risk of pelvic inflammatory disease, the impact of screening for bacterial vaginosis and sexually transmitted infections including chlamydia and gonorrhea; and the role of prophylactic antibiotics. Published literature was retrieved through searches of PubMed, Embase, and The Cochrane Library on July 21, 2011, using appropriate controlled vocabulary (e.g., intrauterine devices, pelvic inflammatory disease) and key words (e.g., adnexitis, endometritis, IUD). An etiological filter was applied in PubMed. The search was limited to the years 2000 forward. There were no language restrictions. Grey (unpublished) literature was identified through searching the web sites of national and international medical specialty societies. The quality of evidence in this document was rated using the criteria described in the Report of the Canadian Task Force on Preventative Health Care (Table). Recommendations 1. All women requesting an intrauterine device should be counselled about the small increased risk of pelvic inflammatory disease in the first 20 days after insertion. (II-2A) 2. All women requesting an intrauterine device should be screened by both history and physical examination for their risk of sexually transmitted infection. Women at increased risk should be tested prior to or at the time of insertion; however, it is not necessary to delay insertion until results are returned. (II-2B) 3. Not enough current evidence is available to support routine screening for bacterial vaginosis at the time of insertion of an intrauterine device in asymptomatic women. (II-2C) 4. Routine use of prophylactic antibiotics is not recommended prior to intrauterine device insertion, although it may be used in certain high-risk situations. (I-C) 5. Standard practice includes cleansing the cervix and sterilizing any instruments that will be used prior to and during insertion of an intrauterine device. (III-C) 6. In treating mild to moderate pelvic inflammatory disease, it is not necessary to remove the intrauterine device during treatment unless the patient requests removal or there is no clinical improvement after 72 hours of appropriate antibiotic treatment. In cases of severe pelvic inflammatory disease, consideration can be given to removing the intrauterine device after an appropriate antibiotic regimen has been started. (I-B) 7. An intrauterine device is a safe, effective option for contraception in an HIV-positive woman. (I-B) 8. An intrauterine device can be considered a first-line contraceptive agent in adolescents. (I-A).

  17. SU-D-BRF-05: A Novel System to Provide Real-Time Image-Guidance for Intrauterine Tandem Insertion and Placement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Price, M; Fontenot, J

    Purpose: To develop a system that provides real-time image-guidance for intrauterine tandem insertion and placement for brachytherapy. Methods: The conceptualized system consists of an intrauterine tandem with a transparent, lensed tip, a flexible miniature fiber optic scope, light source and interface for CCD coupling. The tandem tip was designed to act as a lens providing a wide field-of-view (FOV) with minimal image distortion and focus length appropriate for the application. The system is designed so that once inserted, the image-guidance component of the system can be removed and brachytherapy can be administered without interfering with source transport or disturbing tandemmore » placement. Proof-of-principle studies were conducted to assess the conceptualized system's (1) lens functionality (clarity, focus and FOV) (2) and ability to visualize the cervical os of a female placed in the lithotomy position. Results: A prototype of this device was constructed using a commercial tandem modified to incorporate a transparent tip that internally coupled with a 1.9mm diameter fiber optic cable. The 900mm-long cable terminated at an interface that provided illumination as well as facilitated visualization of patient anatomy on a computer. The system provided a 23mm FOV with a focal length of 1cm and provided clear visualization of the cervix, cervical fornix and cervical os. The optical components of the system are easily removed without perturbing the position of a tandem placed in a common fixation clamp. Conclusion: Clinicians frequently encounter difficulty inserting an intrauterine tandem through the cervical os, circumventing fibrotic tissue or masses within the uterus, and positioning the tandem without perforating the uterus. To mitigate these challenges, we have designed and conducted proof-of- principle studies to discern the utility of a prototype device that provides real-time image-guidance for intrauterine tandem placement using fiber optic components.« less

  18. Comparative biomechanical effectiveness of over-the-counter devices for individuals with a flexible flatfoot secondary to forefoot varus.

    PubMed

    Hurd, Wendy J; Kavros, Steven J; Kaufman, Kenton R

    2010-11-01

    Evaluate effects of a new off-the-shelf insert on frontal plane foot biomechanics and compare effectiveness of the new and an existing off-the-shelf insert and a motion-control shoe in neutralizing frontal plane foot biomechanics. Descriptive. Biomechanics laboratory. Fifteen uninjured subjects with a flexible flatfoot secondary to forefoot varus. Three-dimensional kinematic and kinetic data were collected as subjects walked and jogged at their self-selected speed while wearing a motion-control running shoe, the shoe with a new off-the-shelf insert, and the shoe with an existing off-the-shelf insert. Frontal plane kinematics and rearfoot kinetics were evaluated during stance. Statistical analysis was performed using a repeated measures analysis of variance and Student-Newman-Keuls post hoc tests (α ≤ 0.05). The new insert and motion-control shoe placed the forefoot in a less-everted position than the existing off-the-shelf insert during walking. There were no differences in forefoot kinematics during jogging, nor were there differences in rearfoot motion during walking or jogging. The rearfoot eversion moment was significantly lower with the new off-the-shelf insert compared with the motion-control shoe and the existing insert during walking and jogging. A new off-the-shelf device is available that promotes more neutral frontal plane biomechanics, thus providing a theoretical rationale for using this device for injury prevention and treatment. The comparative biomechanical effectiveness of a motion-control shoe and the orthotic inserts may assist health care professionals in selecting a device to correct the flatfoot structure.

  19. A review on mechanical considerations for chronically-implanted neural probes

    NASA Astrophysics Data System (ADS)

    Lecomte, Aziliz; Descamps, Emeline; Bergaud, Christian

    2018-06-01

    This review intends to present a comprehensive analysis of the mechanical considerations for chronically-implanted neural probes. Failure of neural electrical recordings or stimulation over time has shown to arise from foreign body reaction and device material stability. It seems that devices that match most closely with the mechanical properties of the brain would be more likely to reduce the mechanical stress at the probe/tissue interface, thus improving body acceptance. The use of low Young’s modulus polymers instead of hard substrates is one way to enhance this mechanical mimetism, though compliance can be achieved through a variety of means. The reduction of probe width and thickness in comparison to a designated length, the use of soft hydrogel coatings and the release in device tethering to the skull, can also improve device compliance. Paradoxically, the more compliant the device, the more likely it will fail during the insertion process in the brain. Strategies have multiplied this past decade to offer partial or temporary stiffness to the device to overcome this buckling effect. A detailed description of the probe insertion mechanisms is provided to analyze potential sources of implantation failure and the need for a mechanically-enhancing structure. This leads us to present an overview of the strategies that have been put in place over the last ten years to overcome buckling issues. Particularly, great emphasis is put on bioresorbable polymers and their assessment for neural applications. Finally, a discussion is provided on some of the key features for the design of mechanically-reliable, polymer-based next generation of chronic neuroprosthetic devices.

  20. Towards the use of computationally inserted lesions for mammographic CAD assessment

    NASA Astrophysics Data System (ADS)

    Ghanian, Zahra; Pezeshk, Aria; Petrick, Nicholas; Sahiner, Berkman

    2018-03-01

    Computer-aided detection (CADe) devices used for breast cancer detection on mammograms are typically first developed and assessed for a specific "original" acquisition system, e.g., a specific image detector. When CADe developers are ready to apply their CADe device to a new mammographic acquisition system, they typically assess the CADe device with images acquired using the new system. Collecting large repositories of clinical images containing verified cancer locations and acquired by the new image acquisition system is costly and time consuming. Our goal is to develop a methodology to reduce the clinical data burden in the assessment of a CADe device for use with a different image acquisition system. We are developing an image blending technique that allows users to seamlessly insert lesions imaged using an original acquisition system into normal images or regions acquired with a new system. In this study, we investigated the insertion of microcalcification clusters imaged using an original acquisition system into normal images acquired with that same system utilizing our previously-developed image blending technique. We first performed a reader study to assess whether experienced observers could distinguish between computationally inserted and native clusters. For this purpose, we applied our insertion technique to clinical cases taken from the University of South Florida Digital Database for Screening Mammography (DDSM) and the Breast Cancer Digital Repository (BCDR). Regions of interest containing microcalcification clusters from one breast of a patient were inserted into the contralateral breast of the same patient. The reader study included 55 native clusters and their 55 inserted counterparts. Analysis of the reader ratings using receiver operating characteristic (ROC) methodology indicated that inserted clusters cannot be reliably distinguished from native clusters (area under the ROC curve, AUC=0.58±0.04). Furthermore, CADe sensitivity was evaluated on mammograms with native and inserted microcalcification clusters using a commercial CADe system. For this purpose, we used full field digital mammograms (FFDMs) from 68 clinical cases, acquired at the University of Michigan Health System. The average sensitivities for native and inserted clusters were equal, 85.3% (58/68). These results demonstrate the feasibility of using the inserted microcalcification clusters for assessing mammographic CAD devices.

  1. Model-based assist feature insertion for sub-40nm memory device

    NASA Astrophysics Data System (ADS)

    Suh, Sungsoo; Lee, Suk-joo; Choi, Seong-woon; Lee, Sung-Woo; Park, Chan-hoon

    2009-04-01

    Many issues need to be resolved for a production-worthy model based assist feature insertion flow for single and double exposure patterning process to extend low k1 process at 193 nm immersion technology. Model based assist feature insertion is not trivial to implement either for single and double exposure patterning compared to rule based methods. As shown in Fig. 1, pixel based mask inversion technology in itself has difficulties in mask writing and inspection although it presents as one of key technology to extend single exposure for contact layer. Thus far, inversion technology is tried as a cooptimization of target mask to simultaneously generate optimized main and sub-resolution assists features for a desired process window. Alternatively, its technology can also be used to optimize for a target feature after an assist feature types are inserted in order to simplify the mask complexity. Simplification of inversion mask is one of major issue with applying inversion technology to device development even if a smaller mask feature can be fabricated since the mask writing time is also a major factor. As shown in Figure 2, mask writing time may be a limiting factor in determining whether or not an inversion solution is viable. It can be reasoned that increased number of shot counts relates to increase in margin for inversion methodology. On the other hand, there is a limit on how complex a mask can be in order to be production worthy. There is also source and mask co-optimization which influences the final mask patterns and assist feature sizes and positions for a given target. In this study, we will discuss assist feature insertion methods for sub 40-nm technology.

  2. Remote vacuum or pressure sealing device and method for critical isolated systems

    DOEpatents

    Brock, James David [Newport News, VA; Keith, Christopher D [Newport News, VA

    2012-07-10

    A remote vacuum or pressure sealing apparatus and method for making a radiation tolerant, remotely prepared seal that maintains a vacuum or pressure tight seal throughout a wide temperature range. The remote sealing apparatus includes a fixed threaded sealing surface on an isolated system, a gasket, and an insert consisting of a plug with a protruding sample holder. An insert coupling device, provided for inserting samples within the isolated system, includes a threaded fastener for cooperating with the fixed threaded sealing surface on the isolated system. The insert coupling device includes a locating pin for azimuthal orientation, coupling pins, a tooted coaxial socket wrench, and an insert coupling actuator for actuating the coupling pins. The remote aspect of the sealing apparatus maintains the isolation of the system from the user's environment, safely preserving the user and the system from detrimental effect from each respectively.

  3. Solar Cell Modules With Improved Backskin

    DOEpatents

    Chevrefils, Andre; Grigore, Daniel Gheorghe

    2001-01-23

    The present invention relates to gas turbines and more particularly to a device for controlling the flow of cooling air through a flowpath in a turbine blade. The device can be inserted in the inlet opening of the blade flowpath and be retained therein. The device comprises a plug member for adjusting the flow of cooling air through the flowpath. The plug member comprises a retaining portion for retaining the plug member at the inlet opening of the flowpath and a blocking portion inserted within the flowpath for reducing the cross-sectional area of the inlet opening. Such a device is inexpensive and can be easily inserted in the inlet opening of a blade flowpath and retained therein.

  4. End Restraints for Impact-Energy-Absorbing Tube Specimens

    NASA Technical Reports Server (NTRS)

    Farley, G. L.; Modlin, J. T.

    1985-01-01

    Inexpensive device developed that eliminates tipping problem without affecting crushing process. Device consists of soft sponge-rubber insert approximately 0.5 inches (1.3 centimeters) thick, cut to same diameter as internal diameter of tube specimen. Metal washer, slightly smaller than internal diameter of tube, placed on top of rubber insert. Screw passed through washer and rubber insert and threaded into base of test machine. As screw tightened against washer, rubber insert compressed and expands radially. Radial expansion applies pressure against internal wall of tube specimen, which provides sufficient support to tube to prevent tipping.

  5. Status of the Siberian synchrotron radiation center

    NASA Astrophysics Data System (ADS)

    Ancharov, A. I.; Baryshev, V. B.; Chernov, V. A.; Gentselev, A. N.; Goldenberg, B. G.; Kochubei, D. I.; Korchuganov, V. N.; Kulipanov, G. N.; Kuzin, M. V.; Levichev, E. B.; Mezentsev, N. A.; Mishnev, S. I.; Nikolenko, A. D.; Pindyurin, V. F.; Sheromov, M. A.; Tolochko, B. P.; Sharafutdinov, M. R.; Shmakov, A. N.; Vinokurov, N. A.; Vobly, P. D.; Zolotarev, K. V.

    2005-05-01

    Synchrotron radiation (SR) experiments at the Budker Institute of Nuclear Physics had been started in 1973, and from 1981 the Siberian Synchrotron Radiation Center (SSRC) had an official status as Research Center of the Russian Academy of Sciences. SSRC is the research center, which is open and free of tax for the research teams from Russia and abroad. In this report some technical information about the storage rings—SR sources of the Budker INP, the main directions of activity of SSRC, experimental stations, experimental works and users—is given. Development of the free electron lasers, new SR sources and insertion devices is described.

  6. Evaluation of manhole inserts as structural barriers to mosquito entry into belowground stormwater systems using a simulated treatment device.

    PubMed

    Harbison, Justin E; Metzger, Marco E; Allen, Vaikko; Hu, Renjie

    2009-09-01

    Belowground proprietary stormwater treatment devices can produce mosquitoes, including vectors of West Nile virus. Elimination of vertical entry points such as pick holes in manhole covers may reduce the number of mosquitoes entering and reproducing in these structures. Plastic manhole dish inserts were evaluated as structural barriers against mosquito entry through pick holes in a simulated stormwater treatment device. Inserts were 100% effective at preventing mosquito entry through covers when no other openings existed. In devices configured with an open lateral conveyance pipe, the addition of an insert under the cover reduced mosquito oviposition significantly. Subsequent trials to further elucidate mosquito entry through manhole covers found a significant positive correlation between increasing number of pick holes and mosquito oviposition. Results of the study suggest the potential for manhole dish inserts to decrease the number of mosquitoes entering belowground structures. The different available stormwater treatment systems and site-specific installations may, however, provide a much greater variety of possible alternate entry points for mosquitoes than was addressed in the current study. Further work is needed in field installations to quantify the significance of pick holes to mosquito entry and determine under what conditions, if any, manhole dish inserts would be most effective and appropriate.

  7. Chalcopyrite and Orientation-Patterned Semiconductors for Mid-IR Sources: Modeling, Growth, and Characterization

    DTIC Science & Technology

    2006-11-01

    shallow 120-meV acceptor and residual donor impurities. To produce low -absorption material for use in nonlinear optical devices, it is necessary to reduce...our knowledge, -20x higher than in previously reported works. This is accomplished by simply inserting a layer of low - index material (AlxOy) in the...and thin - film ferromagnetic semiconductors with Curie points above room temperature, and characterization of their magnetic and transport properties

  8. App-assisted external ventricular drain insertion.

    PubMed

    Eftekhar, Behzad

    2016-09-01

    The freehand technique for insertion of an external ventricular drain (EVD) is based on fixed anatomical landmarks and does not take individual variations into consideration. A patient-tailored approach based on augmented-reality techniques using devices such as smartphones can address this shortcoming. The Sina neurosurgical assist (Sina) is an Android mobile device application (app) that was designed and developed to be used as a simple intraoperative neurosurgical planning aid. It overlaps the patient's images from previously performed CT or MRI studies on the image seen through the device camera. The device is held by an assistant who aligns the images and provides information about the relative position of the target and EVD to the surgeon who is performing EVD insertion. This app can be used to provide guidance and continuous monitoring during EVD placement. The author describes the technique of Sina-assisted EVD insertion into the frontal horn of the lateral ventricle and reports on its clinical application in 5 cases as well as the results of ex vivo studies of ease of use and precision. The technique has potential for further development and use with other augmented-reality devices.

  9. Role of nanorods insertion layer in ZnO-based electrochemical metallization memory cell

    NASA Astrophysics Data System (ADS)

    Mangasa Simanjuntak, Firman; Singh, Pragya; Chandrasekaran, Sridhar; Juanda Lumbantoruan, Franky; Yang, Chih-Chieh; Huang, Chu-Jie; Lin, Chun-Chieh; Tseng, Tseung-Yuen

    2017-12-01

    An engineering nanorod array in a ZnO-based electrochemical metallization device for nonvolatile memory applications was investigated. A hydrothermally synthesized nanorod layer was inserted into a Cu/ZnO/ITO device structure. Another device was fabricated without nanorods for comparison, and this device demonstrated a diode-like behavior with no switching behavior at a low current compliance (CC). The switching became clear only when the CC was increased to 75 mA. The insertion of a nanorods layer induced switching characteristics at a low operation current and improve the endurance and retention performances. The morphology of the nanorods may control the switching characteristics. A forming-free electrochemical metallization memory device having long switching cycles (>104 cycles) with a sufficient memory window (103 times) for data storage application, good switching stability and sufficient retention was successfully fabricated by adjusting the morphology and defect concentration of the inserted nanorod layer. The nanorod layer not only contributed to inducing resistive switching characteristics but also acted as both a switching layer and a cation diffusion control layer.

  10. Forgotten/retained double J ureteric stents: A source of severe morbidity in children

    PubMed Central

    Nerli, Rajendra B.; Magdum, Prasad V.; Sharma, Vikas; Guntaka, Ajay Kumar; Hiremath, Murigendra B.; Ghagane, Shridhar

    2016-01-01

    Background: The increase in the usage of double J (DJ) ureteral stents in the management of a variety of urinary tract disease processes mandates familiarity with these devices, their consequences and their potential complications, which at times can be devastating. We retrospectively reviewed our series of children with forgotten/retained DJ ureteric stents. Materials and Methods: Hospital records of all patients’ <18 years old who underwent removal of forgotten/retained DJ ureteral stent at our hospital were reviewed for age, gender, indication for insertion of DJ stent, duration of stent insertion, radiological images and surgical procedures performed. Results: During the study period, January 2000 to December 2014 (a 15-year period), a total of 14 children underwent removal of forgotten/retained DJ ureteral stent. A combination of extracorporeal shock wave lithotripsy, cystolitholapaxy and percutaneous nephrolithotomy was done to free the DJ stent and extract it. Conclusions: Forgotten/retained stents in children are a source of severe morbidity, additional/unnecessary hospitalisation and definitely financial strain. PMID:27251521

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krempasky, J.; Flechsig, U.; Korhonen, T.

    Synchronous monochromator and insertion device energy scans were implemented at the Surfaces/Interfaces:Microscopy (SIM) beamline in order to provide the users fast X-ray magnetic dichroism studies (XMCD). A simple software control scheme is proposed based on a fast monochromator run-time energy readback which quickly updates the insertion device requested energy during an on-the-fly X-ray absorption scan (XAS). In this scheme the Plain Grating Monochromator (PGM) motion control, being much slower compared with the insertion device (APPLE-II type undulator), acts as a 'master' controlling the undulator 'slave' energy position. This master-slave software implementation exploits EPICS distributed device control over computer network andmore » allows for a quasi-synchronous motion control combined with data acquisition needed for the XAS or XMCD experiment.« less

  12. Cholorhexidine, octenidine or povidone iodine for catheter related infections: A randomized controlled trial

    PubMed Central

    Bilir, Ayten; Yelken, Birgül; Erkan, Ayse

    2013-01-01

    Background: Protection of the catheter site by antimicrobial agents is one of the most important factors in the prevention of infection. Povidone iodine and chlorhexidine gluconate are the most common used agents for dressing. The purpose of this study was to compare the effects of povidone iodine, chlorhexidine gluconate and octenidine hydrochloride in preventing catheter related infections. Materials and Methods: Patients were randomized to receive; 4% chlorhexidine gluconate, 10% povidone iodine or octenidine hydrochlorodine for cutaneous antisepsis. Cultures were taken at the site surrounding catheter insertion and at the catheter hub after removal to help identify the source of microorganisms. Results: Catheter related sepsis was 10.5% in the povidone iodine and octenidine hydrochlorodine groups. Catheter related colonization was 26.3% in povidone iodine group and 21.5% in octenidine hydrochlorodine group. Conclusion: 4% chlorhexidine or octenidine hydrochlorodine for cutaneous disinfection before insertion of an intravascular device and for post-insertion site care can reduce the catheter related colonization. PMID:24250702

  13. A microfluidic brain slice perfusion chamber for multisite recording using penetrating electrodes.

    PubMed

    Blake, Alexander J; Rodgers, Frank C; Bassuener, Anna; Hippensteel, Joseph A; Pearce, Thomas M; Pearce, Timothy R; Zarnowska, Ewa D; Pearce, Robert A; Williams, Justin C

    2010-05-30

    To analyze the spatiotemporal dynamics of network activity in a brain tissue slice, it is useful to record simultaneously from multiple locations. When obtained from laminar structures such as the hippocampus or neocortex, multisite recordings also yield information about subcellular current distributions via current source density analysis. Multisite probes developed for in vivo recordings could serve these purposes in vitro, allowing recordings to be obtained from brain slices at sites deeper within the tissue than currently available surface recording methods permit. However, existing recording chambers do not allow for the insertion of lamina-spanning probes that enter through the edges of brain slices. Here, we present a novel brain slice recording chamber design that accomplishes this goal. The device provides a stable microfluidic perfusion environment in which tissue health is optimized by superfusing both surfaces of the slice. Multichannel electrodes can be inserted parallel to the surface of the slice, at any depth relative to the surface. Access is also provided from above for the insertion of additional recording or stimulating electrodes. We illustrate the utility of this recording configuration by measuring current sources and sinks during theta burst stimuli that lead to the induction of long-term potentiation in hippocampal slices. (c) 2010 Elsevier B.V. All rights reserved.

  14. Standard versus Rotation Technique for Insertion of Supraglottic Airway Devices: Systematic Review and Meta-Analysis

    PubMed Central

    Park, Jin Ha; Lee, Jong Seok; Nam, Sang Beom; Ju, Jin Wu

    2016-01-01

    Purpose Supraglottic airway devices have been widely utilized as an alternative to tracheal intubation in various clinical situations. The rotation technique has been proposed to improve the insertion success rate of supraglottic airways. However, the clinical efficacy of this technique remains uncertain as previous results have been inconsistent, depending on the variable evaluated. Materials and Methods We systematically searched PubMed, Embase, and the Cochrane Central Register of Controlled Trials in April 2015 for randomized controlled trials that compared the rotation and standard techniques for inserting supraglottic airways. Results Thirteen randomized controlled trials (1505 patients, 753 with the rotation technique) were included. The success rate at the first attempt was significantly higher with the rotation technique than with the standard technique [relative risk (RR): 1.13; 95% confidence interval (CI): 1.05 to 1.23; p=0.002]. The rotation technique provided significantly higher overall success rates (RR: 1.06; 95% CI: 1.04 to 1.09; p<0.001). Device insertion was completed faster with the rotation technique (mean difference: -4.6 seconds; 95% CI: -7.37 to -1.74; p=0.002). The incidence of blood staining on the removed device (RR: 0.36; 95% CI: 0.27 to 0.47; p<0.001) was significantly lower with the rotation technique. Conclusion The rotation technique provided higher first-attempt and overall success rates, faster insertion, and a lower incidence of blood on the removed device, reflecting less mucosal trauma. Thus, it may be considered as an alternative to the standard technique when predicting or encountering difficulty in inserting supraglottic airways. PMID:27189296

  15. Damage-free back channel wet-etch process in amorphous indium-zinc-oxide thin-film transistors using a carbon-nanofilm barrier layer.

    PubMed

    Luo, Dongxiang; Zhao, Mingjie; Xu, Miao; Li, Min; Chen, Zikai; Wang, Lang; Zou, Jianhua; Tao, Hong; Wang, Lei; Peng, Junbiao

    2014-07-23

    Amorphous indium-zinc-oxide thin film transistors (IZO-TFTs) with damage-free back channel wet-etch (BCE) process were investigated. A carbon (C) nanofilm was inserted into the interface between IZO layer and source/drain (S/D) electrodes as a barrier layer. Transmittance electron microscope images revealed that the 3 nm-thick C nanofilm exhibited a good corrosion resistance to a commonly used H3PO4-based etchant and could be easily eliminated. The TFT device with a 3 nm-thick C barrier layer showed a saturated field effect mobility of 14.4 cm(2) V(-1) s(-1), a subthreshold swing of 0.21 V/decade, an on-to-off current ratio of 8.3 × 10(10), and a threshold voltage of 2.0 V. The favorable electrical performance of this kind of IZO-TFTs was due to the protection of the inserted C to IZO layer in the back-channel-etch process. Moreover, the low contact resistance of the devices was proved to be due to the graphitization of the C nanofilms after annealing. In addition, the hysteresis and thermal stress testing confirmed that the usage of C barrier nanofilms is an effective method to fabricate the damage-free BCE-type devices with high reliability.

  16. A comparison of needle tip localization accuracy using 2D and 3D trans-rectal ultrasound for high-dose-rate prostate cancer brachytherapy treatment planning

    NASA Astrophysics Data System (ADS)

    Hrinivich, W. Thomas; Hoover, Douglas A.; Surry, Kathleen; Edirisinghe, Chandima; Montreuil, Jacques; D'Souza, David; Fenster, Aaron; Wong, Eugene

    2016-03-01

    Background: High-dose-rate brachytherapy (HDR-BT) is a prostate cancer treatment option involving the insertion of hollow needles into the gland through the perineum to deliver a radioactive source. Conventional needle imaging involves indexing a trans-rectal ultrasound (TRUS) probe in the superior/inferior (S/I) direction, using the axial transducer to produce an image set for organ segmentation. These images have limited resolution in the needle insertion direction (S/I), so the sagittal transducer is used to identify needle tips, requiring a manual registration with the axial view. This registration introduces a source of uncertainty in the final segmentations and subsequent treatment plan. Our lab has developed a device enabling 3D-TRUS guided insertions with high S/I spatial resolution, eliminating the need to align axial and sagittal views. Purpose: To compare HDR-BT needle tip localization accuracy between 2D and 3D-TRUS. Methods: 5 prostate cancer patients underwent conventional 2D TRUS guided HDR-BT, during which 3D images were also acquired for post-operative registration and segmentation. Needle end-length measurements were taken, providing a gold standard for insertion depths. Results: 73 needles were analyzed from all 5 patients. Needle tip position differences between imaging techniques was found to be largest in the S/I direction with mean+/-SD of -2.5+/-4.0 mm. End-length measurements indicated that 3D TRUS provided statistically significantly lower mean+/-SD insertion depth error of -0.2+/-3.4 mm versus 2.3+/-3.7 mm with 2D guidance (p < .001). Conclusions: 3D TRUS may provide more accurate HDR-BT needle localization than conventional 2D TRUS guidance for the majority of HDR-BT needles.

  17. FIRST BEAM TESTS OF THE APS MBA UPGRADE ORBIT FEEDBACK CONTROLLER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sereno, N. S.; Arnold, N.; Brill, A.

    The new orbit feedback system required for the APS multi-bend acromat (MBA) ring must meet challenging beam stability requirements. The AC stability requirement is to correct rms beam motion to 10 % the rms beam size at the insertion device source points from 0.01 to 1000 Hz. The vertical plane represents the biggest challenge for AC stability which is required to be 400 nm rms for a 4 micron vertical beam size. In addition long term drift over a period of 7 days is required to be 1 micron or less at insertion de- vice BPMs and 2 microns formore » arc bpms. We present test re- sults of theMBA prototype orbit feedback controller (FBC) in the APS storage ring. In this test, four insertion device BPMs were configured to send data to the FBC for process- ing into four fast corrector setpoints. The configuration of four bpms and four fast correctors creates a 4-bump and the configuration of fast correctors is similar to what will be implemented in the MBA ring. We report on performance benefits of increasing the sampling rate by a factor of 15 to 22.6 kHz over the existing APS orbit feedback system, lim- itations due to existing storage ring hardware and extrapo- lation to theMBA orbit feedback design. FBC architecture, signal flow and processing design will also be discussed.« less

  18. Comparison of the Ambu AuraFlex with the laryngeal mask airway Flexible: a manikin study.

    PubMed

    Sanuki, Takuro; Nakatani, Gosuke; Sugioka, Shingo; Daigo, Erina; Kotani, Junichiro

    2011-07-01

    The present study compared the Ambu AuraFlex and the laryngeal mask airway (LMA) Flexible with regard to time required for and success rates of insertion on a manikin by dental students who had never used an LMA. In addition, participants' views on ease of insertion of each device were surveyed. Subjects consisted of 30 dental students who inserted each airway device in a manikin. The time required for and success rates of insertion were measured. Subjects were then asked to rate the ease of insertion of each device using the 100-mm visual analog scale (from 0 mm = extremely easy to 100 mm = extremely difficult). Insertion time was shorter with the Ambu AuraFlex (26.6 ± 7.1 seconds) than with the LMA Flexible (30.3 ± 6.8 seconds; P = .045). The rate of successful insertion using the Ambu AuraFlex (28 of 30 attempts, 93.3%) was greater than that with the LMA Flexible (23 of 30 attempts, 76.7%), although the difference was not statistically significant (P = .145). Ambu AuraFlex insertion was considered less difficult (median, 41 mm; 10th to 90th percentiles, 18 to 78 mm) than LMA Flexible insertion (60 mm; 42 to 82 mm; P = .004), as rated using the 100-mm visual analog scale. The Ambu AuraFlex appears to be useful for inexperienced users because it enables quicker and easier insertion than the LMA Flexible. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Nanophotonic enhanced quantum emitters

    NASA Astrophysics Data System (ADS)

    Li, Xin; Zhou, Zhang-Kai; Yu, Ying; Gather, Malte; Di Falco, Andrea

    2017-08-01

    Quantum dots are excellent solid-state quantum sources, because of their stability, their narrow spectral linewidth, and radiative lifetime in the range of 1ns. Most importantly, they can be integrated into more complex nanophononics devices, to realize high quality quantum emitters of single photons or entangled photon sources. Recent progress in nanotechnology materials and devices has opened a number of opportunities to increase, optimize and ultimately control the emission property of single quantum dot. In this work, we present an approach that combines the properties of quantum dots with the flexibility of light control offered by nanoplasmonics and metamaterials structuring. Specifically, we show the nanophotonic enhancement of two types of quantum dots devices. The quantum dots are inserted into optical-positioned micropillar cavities, or decorated on the facets of core-shell GaAs/AlGaAs nanowires, fabricated with a bottom-up approach. In both cases, the metallic nanofeatures, which are designed to control the emission and the polarization state of the emitted light, are realized via direct electron-beam-induced deposition. This approach permits to create three-dimensional features with nanometric resolution and positional accuracy, and does not require wet lithographic steps and previous knowledge of the exact spatial arrangement of the quantum devices.

  20. Bone suture anchor fixation in the lower extremity: a review of insertion principles and a comparative biomechanical evaluation.

    PubMed

    Scranton, Pierce E; Lawhon, S Michael; McDermott, John E

    2005-07-01

    Suture anchors have been developed for the fixation of ligaments, capsules, or tendons to bone. These devices have led to improved fixation, smaller incisions, earlier limb mobility, and improved outcomes. They were originally developed for use in shoulder reconstructions but are now used in almost all extremities. In the lower leg they are used in the tibia, the talus, the calcaneus, tarsal bones, and phalanges. Nevertheless, techniques for insertion and mechanisms of failure are not well described. Five suture anchors were studied to determine the pullout strength in four distal cadaver femurs and four proximal cadaver tibias from 55- and 62-year-old males. Eight hundred ninety Newton line was used, testing the anchors to failure with an Instron testing device (Instron, Norwood, MA). The anchor devices were inserted randomly and tested blindly (12 tests per anchor device, 60 tests in all). Two anchors in each group tested failed at low loads. Both types of plastic anchors had failures at the eyelet. Average pullout strength varied from 85.4 to 185.6 N. Insertion techniques are specific for each device, and they must be followed for optimal fixation. In this study, in all five groups of anchors tested two of the 12 anchors in each group failed with minimal force. On the basis of this finding we recommend that, if suture anchor fixation is necessary, at least two anchors should be used. Since there appears to be a percentage of failure in all devices, the second anchor can serve as a backup. It is imperative that surgeons be familiar with the insertion techniques of each device before use.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Casalbuoni, S., E-mail: sara.casalbuoni@kit.edu; Cecilia, A.; Gerstl, S.

    Superconducting undulators (SCUs) have the potential to reach higher brilliance and flux with respect to the state of the art permanent magnet insertion devices. ANKA is collaborating with the industrial partner Babcock Noell GmbH (BNG) to realize NbTi conduction cooled planar devices for low emittance light sources, and is developing the instrumentation to characterize the magnetic field properties and to measure the beam heat load to a cold bore needed for the cryogenic design of SCUs. We present here: the most recent results obtained within the ANKA-BNG collaboration, the progress achieved in the development of the instrumentation, and the inmore » house studies on the application of high temperature superconducting (HTS) tape to the SCU technology.« less

  2. Performance enhancement of pentacene-based organic thin-film transistors using 6,13-pentacenequinone as a carrier injection interlayer

    NASA Astrophysics Data System (ADS)

    Fan, Ching-Lin; Lin, Wei-Chun; Chen, Hao-Wei

    2018-06-01

    This work demonstrates pentacene-based organic thin-film transistors (OTFTs) fabricated by inserting a 6,13-pentacenequinone (PQ) carrier injection layer between the source/drain (S/D) metal Au electrodes and pentacene channel layer. Compared to devices without a PQ layer, the performance characteristics including field-effect mobility, threshold voltage, and On/Off current ratio were significantly improved for the device with a 5-nm-thick PQ interlayer. These improvements are attributed to significant reduction of hole barrier height at the Au/pentacene channel interfaces. Therefore, it is believed that using PQ as the carrier injection layer is a good candidate to improve the pentacene-based OTFTs electrical performance.

  3. 21 CFR 876.5830 - Hemodialyzer with disposable insert (Kiil type).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Hemodialyzer with disposable insert (Kiil type). (a) Identification. A hemodialyzer with disposable inserts (Kiil type) is a device that is used as a part of an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that includes disposable inserts consisting of layers...

  4. Intrauterine device insertion in the postpartum period: a systematic review.

    PubMed

    Sonalkar, Sarita; Kapp, Nathalie

    2015-02-01

    Given new research on postpartum placement of levonorgestrel and copper intrauterine devices (IUDs), our objective was to update a prior systematic review of the safety and expulsion rates of postpartum IUDs. We searched MEDLINE, CENTRAL, LILACS, POPLINE, Web of Science, and ClinicalTrials.gov databases for articles between the database inception until July 2013. We included studies that compared IUD insertion time intervals and routes during the postpartum period. We used standard abstract forms and the United States Preventive Services Task Force grading system to summarise and assess the quality of the evidence. We included 18 articles. New evidence suggests that a levonorgestrel releasing-intrauterine system (LNG-IUS) insertion within 48 hours of delivery is safe. Postplacental insertion and insertion between 10 minutes and 48 hours after delivery result in higher expulsion rates than insertion 4 to 6 weeks postpartum, or non-postpartum insertion. Insertion at the time of caesarean section is associated with lower expulsion rates than postplacental insertion at the time of vaginal delivery. This review supports the evidence that insertion of an intrauterine contraceptive within the first 48 hours of vaginal or caesarean delivery is safe. Expulsion rates should be further studied in larger randomised controlled trials.

  5. Safety lock-out device for electrical appliances

    DOEpatents

    Cliff, P.L. Jr.

    1996-07-09

    A safety lock-out device prevents the insertion of an electrical power cord into an electrical power cord receptacle of an electrical appliance. The device comprises a mounting plate fastened to the appliance and a hinged cover plate attached to the appliance. The cover plate is movable between a first position and a second position such that, in the first position, the cover plate covers and prevents insertion of a power cord into the appliance receptacle. In said second position, the appliance receptacle is uncovered to permit insertion of a power cord into the receptacle. Extending a lock shank through aligned openings formed in flange members extending from the mounting plate, the cover plate locks the cover plate in the first position. 15 figs.

  6. A Tunable Silk Hydrogel Device for Studying Limb Regeneration in Adult Xenopus Laevis

    PubMed Central

    Golding, Anne; Levin, Michael; Kaplan, David L.

    2016-01-01

    In certain amphibian models limb regeneration can be promoted or inhibited by the local wound bed environment. This research introduces a device that can be utilized as an experimental tool to characterize the conditions that promotes limb regeneration in the adult frog (Xenopus laevis) model. In particular, this device was designed to manipulate the local wound environment via a hydrogel insert. Initial characterization of the hydrogel insert revealed that this interaction had a significant influence on mechanical forces to the animal, due to the contraction of the hydrogel. The material and mechanical properties of the hydrogel insert were a factor in the device design in relation to the comfort of the animal and the ability to effectively manipulate the amputation site. The tunable features of the hydrogel were important in determining the pro-regenerative effects in limb regeneration, which was measured by cartilage spike formation and quantified by micro-computed tomography. The hydrogel insert was a factor in the observed morphological outcomes following amputation. Future work will focus on characterizing and optimizing the device’s observed capability to manipulate biological pathways that are essential for limb regeneration. However, the present work provides a framework for the role of a hydrogel in the device and a path forward for more systematic studies. PMID:27257960

  7. Atomic physics research with second and third generation synchrotron light sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, B.M.

    1990-10-01

    This contribution to these proceedings is intended to provide an introduction and overview for other contributions on atomic (and related) physics research at existing and planned synchrotron light sources. The emphasis will be on research accomplishments and future opportunities, but a comparison will be given of operating characteristics for first, second, and third generation machines. First generation light sources were built to do research with the primary electron and positron beams, rather than with the synchrotron radiation itself. Second generation machines were specifically designed to be dedicated synchrotron-radiation facilities, with an emphasis on the use of bending-magnet radiation. The newmore » third generation light sources are being designed to optimize radiation from insertion devices, such as undulators and wigglers. Each generation of synchrotron light source offers useful capabilities for forefront research in atomic physics and many other disciplines. 27 refs., 1 fig., 3 tabs.« less

  8. Fabrication and Characteristics of Pentacene/Vanadium Pentoxide Field-Effect Transistors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Minagawa, M.; Nakai, K.; Baba, A.

    2011-12-23

    Organic field-effect transistors (OFETs) were fabricated using pentacene thin layer, and the effects of inserted Lewis-acid thin layers on electrical properties were investigated. The OFETs have active layers of pentacene and vanadium pentoxide (V{sub 2}O{sub 5}) as a Lewis-acid layer. Typical source-drain current (I{sub DS}) vs. source-drain voltage (V{sub DS}) curves were observed under negative gate voltages (V{sub G}S) application, and the shift of the threshold voltage for FET driving (V{sub t}) to positive side was also observed by V{sub 2}O{sub 5} layer insertion, that is, -2.5 V for device with V{sub 2}O{sub 5} layer and -5.7 V for devicemore » without V{sub 2}O{sub 5} layer. It was thought that charge transfer (CT) complexes which were formed at the interface between pentacene and V{sub 2}O{sub 5} layer were dissociated by the applied gate voltage, and the generated holes seem to contribute to drain current and the apparent V{sub t} improvement.« less

  9. Method and design for externally applied laser welding of internal connections in a high power electrochemical cell

    DOEpatents

    Martin, Charles E; Fontaine, Lucien; Gardner, William H

    2014-01-21

    An electrochemical cell includes components that are welded from an external source after the components are assembled in a cell canister. The cell canister houses electrode tabs and a core insert. An end cap insert is disposed opposite the core insert. An external weld source, such as a laser beam, is applied to the end cap insert, such that the end cap insert, the electrode tabs, and the core insert are electrically coupled by a weld which extends from the end cap insert to the core insert.

  10. Self-pressurized air-Q® intubating laryngeal airway versus the LMA® Classic™: a randomized clinical trial.

    PubMed

    Ha, Sang Hee; Kim, Min-Soo; Suh, Jiwoo; Lee, Jong Seok

    2018-05-01

    The self-pressurized air-Q® (air-Q SP) intubating laryngeal airway is a relatively new supraglottic airway (SGA) device. The intracuff pressure of air-Q dynamically equilibrates with the airway pressure and adjusts to the patient's pharyngeal and periglottic anatomy, potentially providing improved airway fit and seal. The aim of this prospective randomized study was to compare the clinical performance of air-Q to the LMA® Classic™ SGA. Adult patients requiring general anesthesia for elective surgery were prospectively enrolled and randomly assigned to either air-Q SP or the LMA Classic SGA. Oropharyngeal leak pressure (primary endpoint), success rate, insertion features (insertion time, ease of insertion, requirement for device manipulation), sealing function, gastric insufflation, bronchoscopic view, and oropharyngeal complications at device insertion and following its removal (sore throat, dysphagia, dysphonia) were compared. The mean (standard deviation [SD]) oropharyngeal leak pressure just after insertion was similar in the air-Q SP and LMA [16.8 (4.9) vs 18.6 (5.5) cm H 2 O, respectively; mean difference, 1.8 cm H 2 O; 95% CI, -0.5 to 4.2; P = 0.13] and did not differ at ten minutes following device insertion. Median [interquartile range (IQR)] peak inspiratory pressure just after insertion was lower in the air-Q SP (11.0 [10.0-13.0] vs 13.0 [11.0-14.0] cmH 2 O, median difference, 1.0 cm H 2 O; 95% CI, 0.0 to 2.0; P = 0.03) but no difference was observed at ten minutes. The median [IQR] insertion time was faster with the air-Q SP (15.9 [13.6-20.3] sec vs 24 [21.2-27.1] sec; median difference, 8.1 sec; 95% CI, 5.6 to 9.9; P < 0.001) and improved bronchoscopic viewing grade were seen with the air-Q SP immediately after insertion (P < 0.001). No differences between the groups were observed with respect to the rate of successful insertion at first attempt, overall insertion success rate, ease of insertion, and complications. The air-Q SP had similar leak pressures but a faster insertion time and superior bronchoscopic viewing grade when compared with the LMA Classic. The air-Q SP is a suitable alternative to the LMA Classic in adult patients and may be a superior conduit for tracheal intubation. www.clinicaltrials.gov (NCT02206438). Registered 1 August 2014.

  11. Injectable, cellular-scale optoelectronics with applications for wireless optogenetics.

    PubMed

    Kim, Tae-il; McCall, Jordan G; Jung, Yei Hwan; Huang, Xian; Siuda, Edward R; Li, Yuhang; Song, Jizhou; Song, Young Min; Pao, Hsuan An; Kim, Rak-Hwan; Lu, Chaofeng; Lee, Sung Dan; Song, Il-Sun; Shin, Gunchul; Al-Hasani, Ream; Kim, Stanley; Tan, Meng Peun; Huang, Yonggang; Omenetto, Fiorenzo G; Rogers, John A; Bruchas, Michael R

    2013-04-12

    Successful integration of advanced semiconductor devices with biological systems will accelerate basic scientific discoveries and their translation into clinical technologies. In neuroscience generally, and in optogenetics in particular, the ability to insert light sources, detectors, sensors, and other components into precise locations of the deep brain yields versatile and important capabilities. Here, we introduce an injectable class of cellular-scale optoelectronics that offers such features, with examples of unmatched operational modes in optogenetics, including completely wireless and programmed complex behavioral control over freely moving animals. The ability of these ultrathin, mechanically compliant, biocompatible devices to afford minimally invasive operation in the soft tissues of the mammalian brain foreshadow applications in other organ systems, with potential for broad utility in biomedical science and engineering.

  12. Time-elapsed screw insertion with microCT imaging.

    PubMed

    Ryan, M K; Mohtar, A A; Cleek, T M; Reynolds, K J

    2016-01-25

    Time-elapsed analysis of bone is an innovative technique that uses sequential image data to analyze bone mechanics under a given loading regime. This paper presents the development of a novel device capable of performing step-wise screw insertion into excised bone specimens, within the microCT environment, whilst simultaneously recording insertion torque, compression under the screw head and rotation angle. The system is computer controlled and screw insertion is performed in incremental steps of insertion torque. A series of screw insertion tests to failure were performed (n=21) to establish a relationship between the torque at head contact and stripping torque (R(2)=0.89). The test-device was then used to perform step-wise screw insertion, stopping at intervals of 20%, 40%, 60% and 80% between screw head contact and screw stripping. Image data-sets were acquired at each of these time-points as well as at head contact and post-failure. Examination of the image data revealed the trabecular deformation as a result of increased insertion torque was restricted to within 1mm of the outer diameter of the screw thread. Minimal deformation occurred prior to the step between the 80% time-point and post-failure. The device presented has allowed, for the first time, visualization of the micro-mechanical response in the peri-implant bone with increased tightening torque. Further testing on more samples is expected to increase our understanding of the effects of increased tightening torque at the micro-structural level, and the failure mechanisms of trabeculae. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. 78 FR 68714 - Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-15

    ... the device materials must be performed; (iv) Performance data must demonstrate acceptable mechanical properties under simulated clinical use conditions including insertion and removal of the device; (v...

  14. Evaluation of biofeedback seat insert for improving active sitting posture in children with cerebral palsy. A clinical report.

    PubMed

    Bertoti, D B; Gross, A L

    1988-07-01

    Biofeedback devices have been used successfully to improve head control and symmetrical standing in children with cerebral palsy. This clinical report describes a biofeedback seat insert developed to improve erect sitting posture in children with cerebral palsy who have inadequate trunk control. The seat insert is easily placed against the back of any seating device. A momentary-contact pressure switch on the seat insert is activated when the child exerts pressure on it by extending his trunk. The pressure switch then activates a videocassette recorder or can be adapted to activate a television or radio. Five children with spastic cerebral palsy participated in this evaluation of the biofeedback seat insert. The results of this evaluation show that the children used the biofeedback seat insert effectively to actively improve their sitting posture by voluntarily extending their trunk against the pressure switch. The biofeedback seat insert offers physical therapists a valuable therapeutic training tool to encourage carry-over of improved sitting posture away from the clinical setting for children with cerebral palsy.

  15. Apparatus for rendering at least a portion of a device inoperable and related methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daniels, Michael A.; Steffler, Eric D.; Hartenstein, Steven D.

    2016-11-08

    Apparatus for rendering at least a portion of a device inoperable may include a containment structure having a first compartment that is configured to receive a device therein and a movable member configured to receive a cartridge having reactant material therein. The movable member is configured to be inserted into the first compartment of the containment structure and to ignite the reactant material within the cartridge. Methods of rendering at least a portion of a device inoperable may include disposing the device into the first compartment of the containment structure, inserting the movable member into the first compartment of themore » containment structure, igniting the reactant material in the cartridge, and expelling molten metal onto the device.« less

  16. Intelligent vision guide for automatic ventilation grommet insertion into the tympanic membrane.

    PubMed

    Gao, Wenchao; Tan, Kok Kiong; Liang, Wenyu; Gan, Chee Wee; Lim, Hsueh Yee

    2016-03-01

    Otitis media with effusion is a worldwide ear disease. The current treatment is to surgically insert a ventilation grommet into the tympanic membrane. A robotic device allowing automatic grommet insertion has been designed in a previous study; however, the part of the membrane where the malleus bone is attached to the inner surface is to be avoided during the insertion process. This paper proposes a synergy of optical flow technique and a gradient vector flow active contours algorithm to achieve an online tracking of the malleus under endoscopic vision, to guide the working channel to move efficiently during the surgery. The proposed method shows a more stable and accurate tracking performance than the current tracking methods in preclinical tests. With satisfactory tracking results, vision guidance of a suitable insertion spot can be provided to the device to perform the surgery in an automatic way. Copyright © 2015 John Wiley & Sons, Ltd.

  17. The impact of realistic source shape and flexibility on source mask optimization

    NASA Astrophysics Data System (ADS)

    Aoyama, Hajime; Mizuno, Yasushi; Hirayanagi, Noriyuki; Kita, Naonori; Matsui, Ryota; Izumi, Hirohiko; Tajima, Keiichi; Siebert, Joachim; Demmerle, Wolfgang; Matsuyama, Tomoyuki

    2013-04-01

    Source mask optimization (SMO) is widely used to make state-of-the-art semiconductor devices in high volume manufacturing. To realize mature SMO solutions in production, the Intelligent Illuminator, which is an illumination system on Nikon scanner, is useful because it can provide generation of freeform sources with high fidelity to the target. Proteus SMO, which employs co-optimization method and an insertion of validation with mask 3D effect and resist properties for an accurate prediction of wafer printing, can take into account the properties of Intelligent Illuminator. We investigate an impact of the source properties on the SMO to pattern of a static-random access memory. Quality of a source made on the scanner compared to the SMO target is evaluated with in-situ measurement and aerial image simulation using its measurement data. Furthermore we discuss an evaluation of a universality of the source to use it in multiple scanners with a validation with estimated value of scanner errors.

  18. Insertion device calculations with mathematica

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carr, R.; Lidia, S.

    1995-02-01

    The design of accelerator insertion devices such as wigglers and undulators has usually been aided by numerical modeling on digital computers, using code in high level languages like Fortran. In the present era, there are higher level programming environments like IDL{reg_sign}, MatLab{reg_sign}, and Mathematica{reg_sign} in which these calculations may be performed by writing much less code, and in which standard mathematical techniques are very easily used. The authors present a suite of standard insertion device modeling routines in Mathematica to illustrate the new techniques. These routines include a simple way to generate magnetic fields using blocks of CSEM materials, trajectorymore » solutions from the Lorentz force equations for given magnetic fields, Bessel function calculations of radiation for wigglers and undulators and general radiation calculations for undulators.« less

  19. Examination system utilizing ionizing radiation and a flexible, miniature radiation detector probe

    DOEpatents

    Majewski, S.; Kross, B.J.; Zorn, C.J.; Majewski, L.A.

    1996-10-22

    An optimized examination system and method based on the Reverse Geometry X-Ray{trademark} (RGX{trademark}) radiography technique are presented. The examination system comprises a radiation source, at least one flexible, miniature radiation detector probe positioned in appropriate proximity to the object to be examined and to the radiation source with the object located between the source and the probe, a photodetector device attachable to an end of the miniature radiation probe, and a control unit integrated with a display device connected to the photodetector device. The miniature radiation detector probe comprises a scintillation element, a flexible light guide having a first end optically coupled to the scintillation element and having a second end attachable to the photodetector device, and an opaque, environmentally-resistant sheath surrounding the flexible light guide. The probe may be portable and insertable, or may be fixed in place within the object to be examined. An enclosed, flexible, liquid light guide is also presented, which comprises a thin-walled flexible tube, a liquid, preferably mineral oil, contained within the tube, a scintillation element located at a first end of the tube, closures located at both ends of the tube, and an opaque, environmentally-resistant sheath surrounding the flexible tube. The examination system and method have applications in non-destructive material testing for voids, cracks, and corrosion, and may be used in areas containing hazardous materials. In addition, the system and method have applications for medical and dental imaging. 5 figs.

  20. Examination system utilizing ionizing radiation and a flexible, miniature radiation detector probe

    DOEpatents

    Majewski, Stanislaw; Kross, Brian J.; Zorn, Carl J.; Majewski, Lukasz A.

    1996-01-01

    An optimized examination system and method based on the Reverse Geometry X-Ray.RTM. (RGX.RTM.) radiography technique are presented. The examination system comprises a radiation source, at least one flexible, miniature radiation detector probe positioned in appropriate proximity to the object to be examined and to the radiation source with the object located between the source and the probe, a photodetector device attachable to an end of the miniature radiation probe, and a control unit integrated with a display device connected to the photodetector device. The miniature radiation detector probe comprises a scintillation element, a flexible light guide having a first end optically coupled to the scintillation element and having a second end attachable to the photodetector device, and an opaque, environmentally-resistant sheath surrounding the flexible light guide. The probe may be portable and insertable, or may be fixed in place within the object to be examined. An enclosed, flexible, liquid light guide is also presented, which comprises a thin-walled flexible tube, a liquid, preferably mineral oil, contained within the tube, a scintillation element located at a first end of the tube, closures located at both ends of the tube, and an opaque, environmentally-resistant sheath surrounding the flexible tube. The examination system and method have applications in non-destructive material testing for voids, cracks, and corrosion, and may be used in areas containing hazardous materials. In addition, the system and method have applications for medical and dental imaging.

  1. New illuminations approaches with single-use micro LEDs endoilluminators for the pars plana vitrectomy

    NASA Astrophysics Data System (ADS)

    Koelbl, Philipp Simon; Koch, Frank H. J.; Lingenfelder, Christian; Hessling, Martin

    2018-02-01

    The illumination of the intraocular space during pars plana vitrectomy always bears the risk of retina damage by irradiation. Conventional illumination systems consist of an external light source and an optical fiber to transfer the visible light (radiation) into the eye. Often xenon arc and halogen lamps are employed for this application with some disadvantageous properties like high phototoxicity and low efficiency. Therefore, we propose to generate the light directly within the eye by inserting a white micro LED with a diameter of 0.6 mm. The LED offers a luminous flux of 0.6 lm of white light with a blue peak @ 450 nm and a yellow peak @ 555 nm. The presented prototypes fit through a standard 23 G trocar and are the first intraocular light sources worldwide. Two different single-use approaches have already been developed: a handguided and a chandelier device. The hand-guided applicator enables a directly navigation and illumination up to a working distance of 6 mm. The chandelier device is much smaller and does not need an active navigation of the light cone. The brightness and homogeneity of the illumination of these LED devices have been successfully tested on porcine eyes. Presented measurements and calculations prove that even for high LED currents and small distances to the retina these intraocular micro LED devices expose the retina to less hazard than conventional illumination sources like fiber based xenon systems. Even under the worst circumstances application durations of 180 hours would be justifiable.

  2. Outcomes of single- vs double-cuff artificial urinary sphincter insertion in low- and high-risk profile male patients with severe stress urinary incontinence.

    PubMed

    Ahyai, Sascha A; Ludwig, Tim A; Dahlem, Roland; Soave, Armin; Rosenbaum, Clemens; Chun, Felix K-H; Fisch, Margit; Schmid, Marianne; Kluth, Luis A

    2016-10-01

    To evaluate continence and complication rates of bulbar single-cuff (SC) and distal bulbar double-cuff (DC) insertion in male patients with severe stress urinary incontinence (SUI) according to whether the men were considered low or high risk for unfavourable artificial urinary sphincter (AUS) outcomes. In all, 180 male patients who underwent AUS implantation between 2009 and 2013 were followed according to institutional standards. Patients with previous pelvic radiation therapy, open bulbar urethral or UI surgery ('high risk') underwent distal bulbar DC (123 patients) insertion, all others ('low risk') had proximal bulbar SC (57) insertion. Primary and secondary endpoints consisted of continence and complication rates. Kaplan-Meier analysis determined explantation-free survival, and Cox regression models assessed risk factors for persistent UI and explantation. The median follow-up was 24 months. Whereas there was no significant difference in pad usage/objective continence after SC vs DC insertion, superior rates of subjective/social continence and less persistent UI were reported by the patients with DC devices (all P ≤ 0.02). Overall, device explantation (erosion, infection or mechanical failure) occurred in 12.8% of patients. While early (<6 weeks) complication rates compared with SC patients were similar (P > 0.05), DC patients had a 5.7-fold higher risk of device explantation during late follow-up (P = 0.02) and significantly shorter explantation-free survival (log-rank, P = 0.003). Distal bulbar DC insertion in patients with a 'high-risk' profile (previous pelvic radiation, urethral surgery) leads to similar objective continence, but higher explantation rates when compared with patients considered 'low risk' with proximal bulbar SCs. Randomised controlled trials comparing both devices will be needed to determine whether the higher explanations rates are attributable to the DC device or to underlying risk factors. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.

  3. Ab initio modeling of transport and thermodynamic stability for hafnia memristive devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhong, Xiaoliang; Rungger, Ivan; Zapol, Peter

    HfO 2-based memristive switching devices are currently under intensive investigation due to their high performance and mature fabrication techniques. However, several critical issues have to be addressed to bring them from lab to market. We have recently looked into two important issues with the use of density functional theory methods. One is the wide distribution of device resistance in off-states. We have modeled the switching process of a Pt-HfO 2-Pt structure for which quantized conductance was observed. Oxygen atoms moving inside a conductive oxygen vacancy filament divide the filament into several quantum wells. Device conductance changes exponentially when one oxygenmore » atom moves away from interface into filament. We propose that the high sensitivity of device conductance to the position of oxygen atoms results in the large variation of device off-state resistance. Another issue that we have recently addressed is the poor switching performance of devices based on a TiN-HfO 2-TiN structure. While recent experiments have shown that by inserting an "oxygen scavenger" metal between positive electrode and oxide significantly improves device performance, the fundamental understanding of the improvement is lacking.We provide detailed understanding how scavenger layers improve device performance. First, we show that Ta insertion facilitates formation of on-states by reducing the formation energy. Second, the inserted Ta layer reduces the Schottky barrier height in the off-states by changing interface electric dipole at the oxide electrode interface. Nevertheless, the device maintains a high on/off resistance ratio. Finally, with Ta insertion the on-state conductance becomes much less sensitive to the specific location from which the oxygen was removed from the oxide. In conclusion, our studies provide fundamental understanding needed for enabling realization of a non-volatile memory technology with reduced energy consumption.« less

  4. Ab initio modeling of transport and thermodynamic stability for hafnia memristive devices

    DOE PAGES

    Zhong, Xiaoliang; Rungger, Ivan; Zapol, Peter; ...

    2017-09-05

    HfO 2-based memristive switching devices are currently under intensive investigation due to their high performance and mature fabrication techniques. However, several critical issues have to be addressed to bring them from lab to market. We have recently looked into two important issues with the use of density functional theory methods. One is the wide distribution of device resistance in off-states. We have modeled the switching process of a Pt-HfO 2-Pt structure for which quantized conductance was observed. Oxygen atoms moving inside a conductive oxygen vacancy filament divide the filament into several quantum wells. Device conductance changes exponentially when one oxygenmore » atom moves away from interface into filament. We propose that the high sensitivity of device conductance to the position of oxygen atoms results in the large variation of device off-state resistance. Another issue that we have recently addressed is the poor switching performance of devices based on a TiN-HfO 2-TiN structure. While recent experiments have shown that by inserting an "oxygen scavenger" metal between positive electrode and oxide significantly improves device performance, the fundamental understanding of the improvement is lacking.We provide detailed understanding how scavenger layers improve device performance. First, we show that Ta insertion facilitates formation of on-states by reducing the formation energy. Second, the inserted Ta layer reduces the Schottky barrier height in the off-states by changing interface electric dipole at the oxide electrode interface. Nevertheless, the device maintains a high on/off resistance ratio. Finally, with Ta insertion the on-state conductance becomes much less sensitive to the specific location from which the oxygen was removed from the oxide. In conclusion, our studies provide fundamental understanding needed for enabling realization of a non-volatile memory technology with reduced energy consumption.« less

  5. Linear motion device and method for inserting and withdrawing control rods

    DOEpatents

    Smith, Jay E.

    1984-01-01

    A linear motion device, more specifically a control rod drive mechanism (CRDM) for inserting and withdrawing control rods into a reactor core, is capable of independently and sequentially positioning two sets of control rods with a single motor stator and rotor. The CRDM disclosed can control more than one control rod lead screw without incurring a substantial increase in the size of the mechanism.

  6. Macromolecular crystallography beamline X25 at the NSLS

    PubMed Central

    Héroux, Annie; Allaire, Marc; Buono, Richard; Cowan, Matthew L.; Dvorak, Joseph; Flaks, Leon; LaMarra, Steven; Myers, Stuart F.; Orville, Allen M.; Robinson, Howard H.; Roessler, Christian G.; Schneider, Dieter K.; Shea-McCarthy, Grace; Skinner, John M.; Skinner, Michael; Soares, Alexei S.; Sweet, Robert M.; Berman, Lonny E.

    2014-01-01

    Beamline X25 at the NSLS is one of the five beamlines dedicated to macromolecular crystallography operated by the Brookhaven National Laboratory Macromolecular Crystallography Research Resource group. This mini-gap insertion-device beamline has seen constant upgrades for the last seven years in order to achieve mini-beam capability down to 20 µm × 20 µm. All major components beginning with the radiation source, and continuing along the beamline and its experimental hutch, have changed to produce a state-of-the-art facility for the scientific community. PMID:24763654

  7. Parafunctional loading and occlusal device on stress distribution around implants: A 3D finite element analysis.

    PubMed

    Borges Radaelli, Manuel Tomás; Idogava, Henrique Takashi; Spazzin, Aloisio Oro; Noritomi, Pedro Yoshito; Boscato, Noéli

    2018-04-30

    An occlusal device is frequently recommended for patients with bruxism to protect implant-supported restorations and prevent marginal bone loss. Scientific evidence to support this treatment is lacking. The purpose of this 3-dimensional (3D) finite element study was to evaluate the influence of an acrylic resin occlusal device, implant length, and insertion depth on stress distribution with functional and parafunctional loadings. Computer-aided design software was used to construct 8 models. The models were composed of a mandibular bone section including the second premolar and first and second molars. Insertion depths (bone level and 2 mm subcrestal) were simulated at the first molar. Three natural antagonist maxillary teeth and the placement or not of an occlusal device were simulated. Functional (200-N axial and 10-N oblique) and parafunctional (1000-N axial and 25-N oblique) forces were applied. Finite element analysis (FEA) was used to determine the maximum principal stress for the cortical and trabecular bone and von Mises for implant and prosthetic abutment. Stress concentration was observed at the abutment-implant and the implant-bone interfaces. Occlusal device placement changed the pattern of stress distribution and reduced stress levels from parafunctional loading in all structures, except in the trabecular bone. Implants with subcrestal insertion depths had reduced stress at the implant-abutment interface and cortical bone around the implant abutment, while the stress increased in the bone in contact with the implant. Parafunctional loading increased the stress levels in all structures when compared with functional loading. An occlusal device resulted in the lowest stress levels at the abutment and implant and the most favorable stress distribution between the cortical and trabecular bone. Under parafunctional loading, an occlusal device was more effective in reducing stress distribution for longer implants inserted at bone level. Subcrestally, implant insertion yielded the most favorable biomechanical conditions at the abutment-implant interface and at the coronal surface of the cortical bone, mainly when there was no occlusal device. Copyright © 2018 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. Hardware fault insertion and instrumentation system: Mechanization and validation

    NASA Technical Reports Server (NTRS)

    Benson, J. W.

    1987-01-01

    Automated test capability for extensive low-level hardware fault insertion testing is developed. The test capability is used to calibrate fault detection coverage and associated latency times as relevant to projecting overall system reliability. Described are modifications made to the NASA Ames Reconfigurable Flight Control System (RDFCS) Facility to fully automate the total test loop involving the Draper Laboratories' Fault Injector Unit. The automated capability provided included the application of sequences of simulated low-level hardware faults, the precise measurement of fault latency times, the identification of fault symptoms, and bulk storage of test case results. A PDP-11/60 served as a test coordinator, and a PDP-11/04 as an instrumentation device. The fault injector was controlled by applications test software in the PDP-11/60, rather than by manual commands from a terminal keyboard. The time base was especially developed for this application to use a variety of signal sources in the system simulator.

  9. Low cost batch fabrication of microdevices using ultraviolet light-emitting diode photolithography technique

    NASA Astrophysics Data System (ADS)

    Lee, Neam Heng; Swamy, Varghese; Ramakrishnan, Narayanan

    2016-01-01

    Solid-state technology has enabled the use of light-emitting diodes (LEDs) in lithography systems due to their low cost, low power requirement, and higher efficiency relative to the traditional mercury lamp. Uniform irradiance distribution is essential for photolithography to ensure the critical dimension (CD) of the feature fabricated. However, light illuminated from arrays of LEDs can have nonuniform irradiance distribution, which can be a problem when using LED arrays as a source to batch-fabricate multiple devices on a large wafer piece. In this study, the irradiance distribution of an UV LED array was analyzed, and the separation distance between light source and mask optimized to obtain maximum irradiance uniformity without the use of a complex lens. Further, employing a diffuser glass enhanced the fabrication process and the CD loss was minimized to an average of 300 nm. To assess the performance of the proposed technology, batch fabrication of surface acoustic wave devices on lithium niobate substrate was carried out, and all the devices exhibited identical insertion loss of -18 dB at a resonance frequency of 39.33 MHz. The proposed low-cost UV lithography setup can be adapted in academic laboratories for research and teaching on microdevices.

  10. Ultra-low power, highly uniform polymer memory by inserted multilayer graphene electrode

    NASA Astrophysics Data System (ADS)

    Jang, Byung Chul; Seong, Hyejeong; Kim, Jong Yun; Koo, Beom Jun; Kim, Sung Kyu; Yang, Sang Yoon; Gap Im, Sung; Choi, Sung-Yool

    2015-12-01

    Filament type resistive random access memory (RRAM) based on polymer thin films is a promising device for next generation, flexible nonvolatile memory. However, the resistive switching nonuniformity and the high power consumption found in the general filament type RRAM devices present critical issues for practical memory applications. Here, we introduce a novel approach not only to reduce the power consumption but also to improve the resistive switching uniformity in RRAM devices based on poly(1,3,5-trimethyl-3,4,5-trivinyl cyclotrisiloxane) by inserting multilayer graphene (MLG) at the electrode/polymer interface. The resistive switching uniformity was thereby significantly improved, and the power consumption was markedly reduced by 250 times. Furthermore, the inserted MLG film enabled a transition of the resistive switching operation from unipolar resistive switching to bipolar resistive switching and induced self-compliance behavior. The findings of this study can pave the way toward a new area of application for graphene in electronic devices.

  11. Timing of Etonogestrel Implant Insertion After Dilation and Evacuation: A Randomized Controlled Trial.

    PubMed

    Cowett, Allison A; Ali, Rose; Cooper, Mary A; Evans, Mark; Conzuelo, Gabriel; Cremer, Miriam

    2018-05-01

    To compare the 6-month use rate of the etonogestrel implant placed immediately after dilation and evacuation (D&E) with placement 2-4 weeks postprocedure. This is a randomized controlled trial of women seeking abortion between 14 0/7 and 23 5/7 weeks of gestation and desiring the etonogestrel contraceptive implant at an urban family planning clinic. Participants were randomized to device insertion immediately after the D&E compared with delayed insertion in 2-4 weeks. The primary outcome was implant use rate at 6 months after insertion and was determined by follow-up phone interviews. Secondary outcomes included repeat pregnancy rates and method satisfaction. The sample size of 120 participants was calculated based on a power of 0.80 to demonstrate a 20% difference in implant use rates between groups assuming 40% of women overall are not using the device 6 months after the procedure. Between November 2015 and October 2016, 148 participants were enrolled. Seventy-three participants (49.3%) were randomized to and underwent immediate implant insertion after D&E. The remaining 75 (50.6%) were randomized to delayed insertion. There were no significant differences in sociodemographic characteristics between the groups. Placement rate was 100% in the immediate group compared with 42.7% in the delayed group (P<.01). At 6 months, 40 of 43 (93%) women from the immediate group who completed follow-up continued use of the implant, whereas 19 of 30 (63.3%) women from the delayed group who completed follow-up were using the device (P=.002). Follow-up rates were low at 58.9% in the immediate group compared with 40.0% in the delayed group. Women were more likely to be using the etonogestrel implant at 6 months after D&E if they underwent immediate compared with delayed insertion. The very high loss to follow-up rate makes it difficult to draw conclusions about acceptability of the device and pregnancy rates. ClinicalTrials.gov, 02037919.

  12. Peripherally inserted central catheter - insertion

    MedlinePlus

    ... ed. Philadelphia, PA: Elsevier Saunders; 2014:chap 26. Smith SF, Duell DJ, Martin BC, Gonzalez L, Aebersold M. Central vascular access devices. In: Smith SF, Duell DJ, Martin BC, Gonzalez L, Aebersold ...

  13. Temperature and time variations during osteotomies performed with different piezosurgical devices: an in vitro study.

    PubMed

    Delgado-Ruiz, R A; Sacks, D; Palermo, A; Calvo-Guirado, J L; Perez-Albacete, C; Romanos, G E

    2016-09-01

    The aim of this experimental in vitro study was to evaluate the effects of the piezoelectric device in temperature and time variations in standardized osteotomies performed with similar tip inserts in bovine bone blocks. Two different piezosurgical devices were used the OE-F15(®) (Osada Inc., Los Angeles, California, USA) and the Surgybone(®) (Silfradent Inc., Sofia, Forli Cesena, Italy). Serrated inserts with similar geometry were coupled with each device (ST94 insert/test A and P0700 insert/test B). Osteotomies 10 mm long and 3 mm deep were performed in bone blocks resembling type II (dense) and type IV (soft) bone densities with and without irrigation. Thermal changes and time variations were recorded. The effects of bone density, irrigation, and device on temperature changes and time necessary to accomplish the osteotomies were analyzed. Thermal analysis showed significant higher temperatures during piezosurgery osteotomies in hard bone without irrigation (P < 0.05). The type of piezosurgical device did not influence thermal variations (P > 0.05). Time analysis showed that the mean time values necessary to perform osteotomies were shorter in soft bone than in dense bone (P < 0.05). Within the limitations of this in vitro study, it may be concluded that the temperature increases more in piezosurgery osteotomies in dense bone without irrigation; the time to perform the osteotomy with piezosurgery is shorter in soft bone compared to hard bone; and the piezosurgical device have a minimal influence in the temperature and time variations when a similar tip design is used during piezosurgery osteotomies. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Improved aethalometer

    DOEpatents

    Hansen, A.D.

    1988-01-25

    An improved aethalometer having a single light source and a single light detector and two light paths from the light source to the light detector. A quartz fiber filter is inserted in the device, the filter having a collection area in one light path and a reference area in the other light path. A gas flow path through the aethalometer housing allows ambient air to flow through the collection area of the filter so that aerosol particles can be collected on the filter. A rotating disk with an opening therethrough allows light for the light source to pass alternately through the two light paths. The voltage output of the detector is applied to a VCO and the VCO pulses for light transmission separately through the two light paths, are counted and compared to determine the absorption coefficient of the collected aerosol particles. 5 figs.

  15. Enhanced electrical properties of oxide semiconductor thin-film transistors with high conductivity thin layer insertion for the channel region

    NASA Astrophysics Data System (ADS)

    Nguyen, Cam Phu Thi; Raja, Jayapal; Kim, Sunbo; Jang, Kyungsoo; Le, Anh Huy Tuan; Lee, Youn-Jung; Yi, Junsin

    2017-02-01

    This study examined the performance and the stability of indium tin zinc oxide (ITZO) thin film transistors (TFTs) by inserting an ultra-thin indium tin oxide (ITO) layer at the active/insulator interface. The electrical properties of the double channel device (ITO thickness of 5 nm) were improved in comparison with the single channel ITZO or ITO devices. The TFT characteristics of the device with an ITO thickness of less than 5 nm were degraded due to the formation of an island-like morphology and the carriers scattering at the active/insulator interface. The 5 nm-thick ITO inserted ITZO TFTs (optimal condition) exhibited a superior field effect mobility (∼95 cm2/V·s) compared with the ITZO-only TFTs (∼34 cm2/V·s). The best characteristics of the TFT devices with double channel layer are due to the lowest surface roughness (0.14 nm) and contact angle (50.1°) that result in the highest hydrophicility, and the most effective adhesion at the surface. Furthermore, the threshold voltage shifts for the ITO/ITZO double layer device decreased to 0.80 and -2.39 V compared with 6.10 and -6.79 V (for the ITZO only device) under positive and negative bias stress, respectively. The falling rates of EA were 0.38 eV/V and 0.54 eV/V for the ITZO and ITO/ITZO bi-layer devices, respectively. The faster falling rate of the double channel devices suggests that the trap density, including interface trap and semiconductor bulk trap, can be decreased by the ion insertion of a very thin ITO film into the ITZO/SiO2 reference device. These results demonstrate that the double active layer TFT can potentially be applied to the flat panel display.

  16. Spin injection into silicon in three-terminal vertical and four-terminal lateral devices with Fe/Mg/MgO/Si tunnel junctions having an ultrathin Mg insertion layer

    NASA Astrophysics Data System (ADS)

    Sato, Shoichi; Nakane, Ryosho; Hada, Takato; Tanaka, Masaaki

    2017-12-01

    We demonstrate that the spin injection/extraction efficiency is enhanced by an ultrathin Mg insertion layer (⩽2 nm) in Fe /Mg /MgO /n+-Si tunnel junctions. In diode-type vertical three-terminal devices fabricated on a Si substrate, we observe the narrower three-terminal Hanle (N-3TH) signals indicating true spin injection into Si and estimate the spin polarization in Si to be 16% when the thickness of the Mg insertion layer is 1 nm, whereas no N-3TH signal is observed without the Mg insertion. This means that the spin injection/extraction efficiency is enhanced by suppressing the formation of a magnetically dead layer at the Fe/MgO interface. We also observe clear spin transport signals, such as nonlocal Hanle signals and spin-valve signals, in a lateral four-terminal device with the same Fe /Mg /MgO /n+-Si tunnel junctions fabricated on a Si-on-insulator substrate. It is found that both the intensity and linewidth of the spin signals are affected by the geometrical effects (device geometry and size). We have derived analytical functions taking into account the device structures, including channel thickness and electrode size, and estimated important parameters: spin lifetime and spin polarization. Our analytical functions explain the experimental results very well. Our study shows the importance of suppressing a magnetically dead layer and provides a unified understanding of spin injection/detection signals in different device geometries.

  17. Effectiveness of electrocardiographic guidance in CVAD tip placement.

    PubMed

    Walker, Graham; Chan, Raymond J; Alexandrou, Evan; Webster, Joan; Rickard, Claire

    International standard practice for the correct confirmation of the central venous access device is the chest X-ray. The intracavitary electrocardiogram-based insertion method is radiation-free, and allows real-time placement verification, providing immediate treatment and reduced requirement for post-procedural repositioning. Relevant databases were searched for prospective randomised controlled trials (RCTs) or quasi RCTs that compared the effectiveness of electrocardiogram-guided catheter tip positioning with placement using surface-anatomy-guided insertion plus chest X-ray confirmation. The primary outcome was accurate catheter tip placement. Secondary outcomes included complications, patient satisfaction and costs. Five studies involving 729 participants were included. Electrocardiogram-guided insertion was more accurate than surface anatomy guided insertion (odds ratio: 8.3; 95% confidence interval (CI) 1.38; 50.07; p=0.02). There was a lack of reporting on complications, patient satisfaction and costs. The evidence suggests that intracavitary electrocardiogram-based positioning is superior to surface-anatomy-guided positioning of central venous access devices, leading to significantly more successful placements. This technique could potentially remove the requirement for post-procedural chest X-ray, especially during peripherally inserted central catheter (PICC) line insertion.

  18. Acute changes associated with electrode insertion measured with optical coherence microscopy

    NASA Astrophysics Data System (ADS)

    Hammer, Daniel X.; Lozzi, Andrea; Boretsky, Adam; Agrawal, Anant; Welle, Cristin G.

    2016-03-01

    Despite advances in functional neural imaging, penetrating microelectrodes provide the most direct interface for the extraction of neural signals from the nervous system and are a critical component of many high degree-of-freedom braincomputer interface devices. Electrode insertion is a traumatic event that elicits a complex neuroinflammatory response. In this investigation we applied optical coherence microscopy (OCM), particularly optical coherence angiography (OCA), to characterize the immediate tissue response during microelectrode insertion. Microelectrodes of varying dimension and footprint (one-, two-, and four-shank) were inserted into mouse motor cortex beneath a window after craniotomy surgery. The microelectrodes were inserted in 3-4 steps at 15-20°, with approximately 250 μm linear insertion distance for each step. Before insertion and between each step, OCM datasets were collected, including for quantitative capillary velocimetry. A cohort of control animals without microelectrode insertion was also imaged over a similar time period (2-3 hours). Mechanical tissue deformation was observed in all the experimental animals. The quantitative angiography results varied across animals, and were not correlated with device dimensions. In some cases, localized flow drop-out was observed in a small region surrounding the electrode, while in other instances a global disruption in flow occurred, perhaps as a result of large vessel compression caused by mechanical pressure. OCM is a tool that can be used in various neurophotonics applications, including quantification of the neuroinflammatory response to penetrating electrode insertion.

  19. Electron current extraction from a permanent magnet waveguide plasma cathode.

    PubMed

    Weatherford, B R; Foster, J E; Kamhawi, H

    2011-09-01

    An electron cyclotron resonance plasma produced in a cylindrical waveguide with external permanent magnets was investigated as a possible plasma cathode electron source. The configuration is desirable in that it eliminates the need for a physical antenna inserted into the plasma, the erosion of which limits operating lifetime. Plasma bulk density was found to be overdense in the source. Extraction currents over 4 A were achieved with the device. Measurements of extracted electron currents were similar to calculated currents, which were estimated using Langmuir probe measurements at the plasma cathode orifice and along the length of the external plume. The influence of facility effects and trace ionization in the anode-cathode gap are also discussed. © 2011 American Institute of Physics

  20. Sweat collection capsule

    NASA Technical Reports Server (NTRS)

    Delaplaine, R. W.; Greenleaf, J. E.

    1979-01-01

    Capsule, with filter paper insert, is used to collect sweat for rate monitoring, chromatographic analysis, or active sweat gland location within specified area. Construction of capsule allows change of inserts while device remains strapped in place.

  1. Comparative Efficacy of the Air-Q Intubating Laryngeal Airway during General Anesthesia in Pediatric Patients: A Systematic Review and Meta-Analysis.

    PubMed

    Ahn, Eun Jin; Choi, Geun Joo; Kang, Hyun; Baek, Chong Wha; Jung, Yong Hun; Woo, Young Cheol; Bang, Si Ra

    2016-01-01

    Air-Q® (air-Q) is a supraglottic airway device which can be used as a guidance of intubation in pediatric as well as in adult patients. We evaluated the efficacy and safety of air-Q compared to other airway devices during general anesthesia in pediatric patients by conducting a systematic review and meta-analysis. A total of 10 studies including 789 patients were included in the final analysis. Compared with other supraglottic airway devices, air-Q showed no evidence for a difference in leakage pressure and insertion time. The ease of insertion was significantly lower than other supraglottic airway devices. The success rate of intubation was significantly lower than other airway devices. However, fiberoptic view was better through the air-Q than other supraglottic airway devices. Therefore, air-Q could be a safe substitute for other airway devices and may provide better fiberoptic bronchoscopic view.

  2. Two-year continuation of intrauterine devices and contraceptive implants in a mixed-payer setting: a retrospective review.

    PubMed

    Sanders, Jessica N; Turok, David K; Gawron, Lori M; Law, Amy; Wen, Lonnie; Lynen, Richard

    2017-06-01

    As the popularity of long-acting reversible contraception increases, so does the need for accurate data on method continuation in diverse clinical settings. We determined 2-year continuation rates for the levonorgestrel 52-mg intrauterine device, the copper T380A intrauterine device, and the 68-mg etonogestrel contraceptive implant in an academic healthcare system with mixed-payer reimbursement. The purpose of this study was to examine the proportion and characteristics of women who continue intrauterine device and implant use to 2 years and to relate continuation to device type when controlling for patient characteristics. This retrospective chart review assessed University of Utah Healthcare System patients who had an intrauterine device or contraceptive implant inserted between January 1, 2004, and December 31, 2012. We identified users and dates of insertions and removals by querying billing, medication, and procedural data in the Electronic Data Warehouse. Multivariable Poisson regression was conducted to estimate incidence risk ratios and to relate the probability of 2-year continuous use to device type. Data on 8603 device insertions were obtained with the following distribution: levonorgestrel 52-mg intrauterine devices (6459; 75.1%), copper T380A intrauterine devices (1136; 13.2%), and 68-mg etonogestrel implant (1008; 11.7%). Two-year continuation rates were 77.8%, 73.1%, and 75.9%, respectively. There was no statistical difference in 2-year continuation between levonorgestrel 52-mg intrauterine device users (adjusted risk ratio, 1.1; 95% confidence interval, 1.0-1.1) and 68-mg etonogestrel implant users (adjusted risk ratio, 1.1; 95% confidence interval, 1.0-1.1) compared with copper device users, after we controlled for age, Hispanic ethnicity, payer type, and year of insertion. Older-age, self-pay, or public payer insurance (reference commercial payer) and Hispanic ethnicity were associated with 2-year continuation. Three-quarters of women with an intrauterine device or implant continue using it for 2 years. In this cohort, the 2-year continuation rates were 77.8%, 73.1%, and 75.9% for the levonorgestrel 52-mg intrauterine device, copper T380A intrauterine device, and 68-mg etonogestrel implant, respectively. Copyright © 2017. Published by Elsevier Inc.

  3. 21 CFR 868.5730 - Tracheal tube.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5730 Tracheal tube. (a) Identification. A tracheal tube is a device inserted into a patient's trachea via the nose or mouth and used to maintain an open airway. (b...

  4. Scanning Electrochemical Microscopy as a Novel Proximity Sensor for Atraumatic Cochlear Implant Insertion

    PubMed Central

    Velmurugan, J.; Mirkin, M. V.; Svirsky, M. A.; Lalwani, A. K.; Llinas, R. R.

    2014-01-01

    A growing number of minimally invasive surgical and diagnostic procedures require the insertion of an optical, mechanical, or electronic device in narrow spaces inside a human body. In such procedures, precise motion control is essential to avoid damage to the patient’s tissues and/or the device itself. A typical example is the insertion of a cochlear implant which should ideally be done with minimum physical contact between the moving device and the cochlear canal walls or the basilar membrane. Because optical monitoring is not possible, alternative techniques for sub millimeter-scale distance control can be very useful for such procedures. The first requirement for distance control is distance sensing. We developed a novel approach to distance sensing based on the principles of scanning electrochemical microscopy (SECM). The SECM signal, i.e., the diffusion current to a microelectrode, is very sensitive to the distance between the probe surface and any electrically insulating object present in its proximity. With several amperometric microprobes fabricated on the surface of an insertable device, one can monitor the distances between different parts of the moving implant and the surrounding tissues. Unlike typical SECM experiments, in which a disk-shaped tip approaches a relatively smooth sample, complex geometries of the mobile device and its surroundings make distance sensing challenging. Additional issues include the possibility of electrode surface contamination in biological fluids and the requirement for a biologically compatible redox mediator. PMID:24845292

  5. Analysis of Nonlinear Insertion Loss of Hearing Protection Devices using an Acoustic Test Fixture

    DTIC Science & Technology

    2015-09-01

    USAARL Report No. 2016-05 Analysis of Nonlinear Insertion Loss of Hearing Protection Devices using an Acoustic Test Fixture By Robert Williams1...through circuitry. Talk through circuits use electro- acoustic transducers to pass ambient sounds through the protector. When the circuitry detects...the SPL of the acoustic insult. If the protective capacity is variable, it should be accounted for in the selection of appropriate HPDs. REAT

  6. Linear motion device and method for inserting and withdrawing control rods

    DOEpatents

    Smith, J.E.

    Disclosed is a linear motion device and more specifically a control rod drive mechanism (CRDM) for inserting and withdrawing control rods into a reactor core. The CRDM and method disclosed is capable of independently and sequentially positioning two sets of control rods with a single motor stator and rotor. The CRDM disclosed can control more than one control rod lead screw without incurring a substantial increase in the size of the mechanism.

  7. 21 CFR 886.4300 - Intraocular lens guide.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4300 Intraocular lens guide. (a) Identification. An intraocular lens guide is a device intended to be inserted into the eye during surgery to direct... lenses, the device is exempt from the premarket notification procedures in subpart E of part 807 of this...

  8. A Wirelessly Powered and Controlled Device for Optical Neural Control of Freely-Behaving Animals

    PubMed Central

    Wentz, Christian T.; Bernstein, Jacob G.; Monahan, Patrick; Guerra, Alexander; Rodriguez, Alex; Boyden, Edward S.

    2011-01-01

    Optogenetics, the ability to use light to activate and silence specific neuron types within neural networks in vivo and in vitro, is revolutionizing neuroscientists’ capacity to understand how defined neural circuit elements contribute to normal and pathological brain functions. Typically awake behaving experiments are conducted by inserting an optical fiber into the brain, tethered to a remote laser, or by utilizing an implanted LED, tethered to a remote power source. A fully wireless system would enable chronic or longitudinal experiments where long duration tethering is impractical, and would also support high-throughput experimentation. However, the high power requirements of light sources (LEDs, lasers), especially in the context of the high-frequency pulse trains often desired in experiments, precludes battery-powered approaches from being widely applicable. We have developed a headborne device weighing 2 grams capable of wirelessly receiving power using a resonant RF power link and storing the energy in an adaptive supercapacitor circuit, which can algorithmically control one or more headborne LEDs via a microcontroller. The device can deliver approximately 2W of power to the LEDs in steady state, and 4.3W in bursts. We also present an optional radio transceiver module (1 gram) which, when added to the base headborne device, enables real-time updating of light delivery protocols; dozens of devices can be simultaneously controlled from one computer. We demonstrate use of the technology to wirelessly drive cortical control of movement in mice. These devices may serve as prototypes for clinical ultra-precise neural prosthetics that use light as the modality of biological control. PMID:21701058

  9. 21 CFR 868.1910 - Esophageal stethoscope.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Esophageal stethoscope. 868.1910 Section 868.1910...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1910 Esophageal stethoscope. (a) Identification. An esophageal stethoscope is a nonpowered device that is inserted into a patient's esophagus to...

  10. Acrylic and metal based Y-branch plastic optical fiber splitter with optical NOA63 polymer waveguide taper region

    NASA Astrophysics Data System (ADS)

    Ehsan, Abang Annuar; Shaari, Sahbudin; Rahman, Mohd Kamil Abd.

    2011-01-01

    We proposed a simple low-cost acrylic and metal-based Y-branch plastic optical fiber (POF) splitter which utilizes a low cost optical polymer glue NOA63 as the main waveguiding medium at the waveguide taper region. The device is composed of three sections: an input POF waveguide, a middle waveguide taper region and output POF waveguides. A desktop high speed CNC engraver is utilized to produce the mold inserts used for the optical devices. Short POF fibers are inserted into the engraved slots at the input and output ports. UV curable optical polymer glue NOA63 is injected into the waveguide taper region and cured. The assembling is completed when the top plate is positioned to enclose the device structure and connecting screws are secured. Both POF splitters have an average insertion loss of 7.8 dB, coupling ratio of 55: 45 and 57: 43 for the acrylic and metal-based splitters respectively. The devices have excess loss of 4.82 and 4.73 dB for the acrylic and metal-based splitters respectively.

  11. Armored garment for protecting

    DOEpatents

    Purvis, James W [Albuquerque, NM; Jones, II, Jack F.; Whinery, Larry D [Albuquerque, NM; Brazfield, Richard [Albuquerque, NM; Lawrie, Catherine [Tijeras, NM; Lawrie, David [Tijeras, NM; Preece, Dale S [Watkins, CO

    2009-08-11

    A lightweight, armored protective garment for protecting an arm or leg from blast superheated gases, blast overpressure shock, shrapnel, and spall from a explosive device, such as a Rocket Propelled Grenade (RPG) or a roadside Improvised Explosive Device (IED). The garment has a ballistic sleeve made of a ballistic fabric, such as an aramid fiber (e.g., KEVLAR.RTM.) cloth, that prevents thermal burns from the blast superheated gases, while providing some protection from fragments. Additionally, the garment has two or more rigid armor inserts that cover the upper and lower arm and protect against high-velocity projectiles, shrapnel and spall. The rigid inserts can be made of multiple plies of a carbon/epoxy composite laminate. The combination of 6 layers of KEVLAR.RTM. fabric and 28 plies of carbon/epoxy laminate inserts (with the inserts being sandwiched in-between the KEVLAR.RTM. layers), can meet the level IIIA fragmentation minimum V.sub.50 requirements for the US Interceptor Outer Tactical Vest.

  12. Improvement of the radiographic method for measurement of effective energy of pulsed X-ray emission from a PF device for different anode's insert materials.

    PubMed

    Miremad, Seyed Milad; Shirani, Babak

    2018-06-01

    In this paper, effective energy of pulsed X-Ray emitted from a Mather-type plasma focus device in stored energy of 2.5 kJ with six different anode's insert materials was measured using radiographic method with attenuation filters. Since intensity and energy of X-ray beam were considerably changed with changing the insert material, the method was improved by using different filters simultaneously in all the experiments and selection of the best filter in each experiment according to the appropriate criteria. Effective energy of pulsed X-ray beam was measured 16, 28, 50, 51, 34 and 44 keV when aluminum, copper, zinc, tin, tungsten and lead were used as insert materials, and aluminum, copper, silver, silver, copper and lead were used as filters, respectively. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. The first insertion devices at SSRL - some personal recollections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winick, H.

    1995-02-01

    The author recounts his experiences with insertion devices at the Stanford Synchrotron Radiation Laboratory. His first experiences with wigglers occured at the Cambridge Electron Accelerator, and was carried over to SSRL with the proposal for a six pole electromagnetic wiggler. Most modern undulators, and many wigglers are now designed around permanent magnets, and the origin of this transition at SSRL was rather fortuitous and humorous. It reflects some of the personality characteristics of Klaus Halbach.

  14. Double-double bend achromat cell upgrade at the Diamond Light Source: From design to commissioning

    NASA Astrophysics Data System (ADS)

    Bartolini, R.; Abraham, C.; Apollonio, M.; Bailey, C. P.; Cox, M. P.; Day, A.; Fielder, R. T.; Hammond, N. P.; Heron, M. T.; Holdsworth, R.; Kay, J.; Martin, I. P. S.; Mhaskar, S.; Miller, A.; Pulampong, T.; Rehm, G.; Rial, E. C. M.; Rose, A.; Shahveh, A.; Singh, B.; Thomson, A.; Walker, R. P.

    2018-05-01

    Diamond has recently successfully commissioned a major change in the lattice consisting of the substitution of a standard double-bend achromat (DBA) cell with a modified four-bend achromat (4BA) cell called "double-double bend achromat" (DDBA). This work stems from the original studies initiated in 2012 towards a Diamond upgrade and provides the benefit of an additional straight section in the ring available for insertion devices. This paper reviews the DDBA design and layout, the implications for technical subsystems, the associated engineering challenges and the main results of the commissioning completed in April 2017.

  15. Haptic device for a ventricular shunt insertion simulator.

    PubMed

    Panchaphongsaphak, Bundit; Stutzer, Diego; Schwyter, Etienne; Bernays, René-Ludwig; Riener, Robert

    2006-01-01

    In this paper we propose a new one-degree-of-freedom haptic device that can be used to simulate ventricular shunt insertion procedures. The device is used together with the BRAINTRAIN training simulator developed for neuroscience education, neurological data visualization and surgical planning. The design of the haptic device is based on a push-pull cable concept. The rendered forces produced by a linear motor connected at one end of the cable are transferred to the user via a sliding mechanism at the end-effector located at the other end of the cable. The end-effector provides the range of movement up to 12 cm. The force is controlled by an open-loop impedance algorithm and can become up to 15 N.

  16. Efficacy of the laryngeal tube by inexperienced personnel.

    PubMed

    Asai, Takashi; Hidaka, Ikuriho; Kawachi, Shoji

    2002-11-01

    We compared the laryngeal tube and the laryngeal mask in the ease of insertion, ventilation volume and the incidence of gastric insufflation by inexperienced personnel. In a randomized, cross-over design, each of 28 students of a Fire Defense Academy attempted to insert the laryngeal tube and laryngeal mask in turn using an airway management trainer manikin. A self-inflating bag (2000 ml) was attached and ventilation volume was measured. The number of attempts at the insertion and the presence or absence of gastric insufflation were also recorded. After completion of the study, each student was asked whether insertion of one device was easier than the other. All 28 students could insert the laryngeal tube at the first attempt. As for the laryngeal mask, 27 could insert it at the first attempt, whereas the remaining one student could insert it after two attempts. The tidal volume was significantly greater for the laryngeal tube (median 842 ml) than the laryngeal mask (median 716 ml) (95%CI for median difference: 10-116 ml; P < 0.02). The incidence of gastric insufflation was significantly lower for the laryngeal tube (2 times) than for the laryngeal mask (10 times) (P < 0.05). Twenty six of 28 students stated that insertion of the laryngeal tube was easier than insertion of the laryngeal mask, whereas the remaining two stated that there was no difference in the ease of insertion between two devices. Therefore, the laryngeal tube has a potential role in providing a clear airway during cardiopulmonary resuscitation. Copyright 2002 Elsevier Science Ireland Ltd.

  17. Comparison of the Proseal LMA and intersurgical I-gel during gynecological laparoscopy

    PubMed Central

    Jeon, Woo Jae; Baek, Seong Jin; Kim, Kyoung Hun

    2012-01-01

    Background The relatively recently developed I-gel (Intersurgical Ltd., Workingham, England) is a supraglottic airway device designed for single-use that, unlike conventional LMAs, does not require an inflatable cuff. In addition, the I-gel, much like the Proseal LMA (PLMA), has a gastric drainage tube associated with an upper tube for decompression of the stomach, thereby avoiding acid reflux and decreasing the risk of pulmonary absorption. The purpose of this study was to compare PLMA and I-gel devices in patients undergoing gynecological laparoscopy based on sealing pressure before and during pneumoperitoneum, insertion time, and gas exchange. Methods Following Institutional Review Board approval and written informed consent, 30 adult patients were randomly allocated to one of two groups (the PLMA or I-gel group). In each case, insertion time and number of attempts were recorded. After successful insertion, airway leak pressure was measured. Results Successful insertion and mechanical ventilation with both supraglottic airway devices was achieved on the first attempt in all 30 patients, and there were no significant differences with respect to insertion time. Likewise, leak pressure did not vary significantly either between or within groups after CO2 insufflation. In addition, differences between leak volume and leak fraction between groups were not significant. Conclusions The results of our study indicate that the I-gel is a reasonable alternative to the PLMA for controlled ventilation during laparoscopic gynecologic surgery. PMID:23277811

  18. Clinical performance of a new blood control peripheral intravenous catheter: A prospective, randomized, controlled study.

    PubMed

    Seiberlich, Laura E; Keay, Vanessa; Kallos, Stephane; Junghans, Tiffany; Lang, Eddy; McRae, Andrew D

    2016-03-01

    The performance of a new safety peripheral intravenous catheter (PIVC) that contains a blood control feature in the hub (blood control) was compared against the current hospital standard without blood control (standard). In this prospective, non-blinded trial, patients were randomized 1:1 to receive either device. Insertions were performed and rated by emergency room nurses. Primary endpoints included clinical acceptability, incidence of blood leakage, and risk of blood exposure. Secondary endpoints were digital compression, insertion success, and usability. 15 clinicians performed 152 PIVC insertions (73 blood control, 79 standard). Clinical acceptability of the blood control device (100%) was non-inferior to the standard (98.7%) (p < 0.0001). The blood control device had a lower incidence of blood leakage (14.1% vs 68.4%), was superior in eliminating the risk of blood exposure (93.9% vs 19.1%) and the need for digital compression (95.3% vs 19.1%), while maintaining non-inferior insertion success rates (95.9% vs 93.7%) and usability ratings (p < 0.0001). In comparison with the hospital-standard, the new safety PIVC with integrated blood control valve had similar clinical acceptability ratings yet demonstrated superior advantages to both clinicians and patients to decrease blood leakage and the clinician's risk of blood exposure, during the insertion process. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Beam Loss Simulation and Collimator System Configurations for the Advanced Photon Source Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xiao, A.; Borland, M.

    The proposed multi-bend achromat lattice for the Advanced Photon Source upgrade (APS-U) has a design emittance of less than 70 pm. The Touschek loss rate is high: compared with the current APS ring, which has an average beam lifetime ~ 10 h, the simulated beam lifetime for APS-U is only ~2 h when operated in the high flux mode (I=200 mA in 48 bunches). An additional consequence of the short lifetime is that injection must be more frequent, which provides another potential source of particle loss. In order to provide information for the radiation shielding system evaluation and to avoidmore » particle loss in sensitive locations around the ring (for example, insertion device straight sections), simulations of the detailed beam loss distribution have been performed. Several possible collimation configurations have been simulated and compared.« less

  20. 47 CFR 2.1204 - Import conditions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... generations of a particular model under development are considered to be separate devices. (4) The radio... particular model under development are considered to be separate devices. (5) The radio frequency device is... offered for sale or marketed. (9) The radio frequency device is a medical implant transmitter inserted in...

  1. 47 CFR 2.1204 - Import conditions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... generations of a particular model under development are considered to be separate devices. (4) The radio... particular model under development are considered to be separate devices. (5) The radio frequency device is... offered for sale or marketed. (9) The radio frequency device is a medical implant transmitter inserted in...

  2. 21 CFR 876.4500 - Mechanical lithotriptor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Mechanical lithotriptor. 876.4500 Section 876.4500...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4500 Mechanical lithotriptor. (a) Identification. A mechanical lithotriptor is a device with steel jaws that is inserted into the urinary bladder...

  3. Patients' perspectives about why they have their contraceptive Implanon NXT device removed early.

    PubMed

    Flore, Meike; Chen, Xiaoshuang Lilly; Bonney, Andrew; Mullan, Judy; Dijkmans-Hadley, Bridget; Hodgkins, Adam; Evans, Gina; Frew, Haley; Lloyd, Gail

    2016-10-01

    Women with long-acting, reversible contraceptive devices inserted may choose to remove them prior to their planned expiry dates. The objective of this study was to explore Australian women's experiences with the etonogestrel subdermal contraceptive implant (Implanon NXT) and why they had it removed early. Semi-structured interviews were conducted with 18 women between June 2013 and January 2014. Transcriptions of the audio-taped interviews were analysed using a constant comparative analysis framework. Two core themes of participants' responses that were identified in this study were influences on choice of contraception, which included convenience and information sources; and influences on removal of contraception, which included side effects and their negative impacts on relationships and financial costs. This study highlights that women's experiences with side effects contribute to the early removal of long-acting contraceptive devices such as Implanon NXT. This study emphasises the importance of general practitioners (GPs) in providing comprehensive information about the benefits and potential side effects associated with using these implants.

  4. A Plasma Focus Device with a 2-MA Discharge Current as a Hard X-Ray Source

    NASA Astrophysics Data System (ADS)

    Yurkov, D. I.; Dulatov, A. K.; Lemeshko, B. D.; Andreev, D. A.; Golikov, A. V.; Mikhailov, Yu. V.; Prokuratov, I. A.; Selifanov, A. N.; Fatiev, T. S.

    2018-04-01

    A device based on a pulsed current generator with capacitive energy storage loaded on a plasma focus (PF) chamber is described. The device provides a discharge current amplitude of up to 2 MA in the PF chamber at a stored energy in the capacitor bank of up to 150 kJ. The PF chamber is designed to study hard X-ray (HXR) emission. It has windows for output of HXR emission in the cathode direction, as well as a special insert for output of HXR emission into the anode cavity. A study of operation of the chamber as a part of the setup with the use of various X-ray targets on the anode has been carried out. At a discharge current of 1.5MA, an HXR pulse with an average duration of 16 ns and energy spectrum from 10 to 200 keV, which provides an absorbed dose in the irradiated samples on the order of 1 Sv, is generated in the PF chamber.

  5. Use of programmable versus nonprogrammable shunts in the management of hydrocephalus secondary to aneurysmal subarachnoid hemorrhage: a retrospective study with cost-benefit analysis.

    PubMed

    Lee, Lester; King, Nicolas K K; Kumar, Dinesh; Ng, Yew Poh; Rao, Jai; Ng, Huiyu; Lee, Kah Keow; Wang, Ernest; Ng, Ivan

    2014-10-01

    The choice of programmable or nonprogrammable shunts for the management of hydrocephalus after aneurysmal subarachnoid hemorrhage (SAH) remains undefined. Variable intracranial pressures make optimal management difficult. Programmable shunts have been shown to reduce problems with drainage, but at 3 times the cost of nonprogrammable shunts. All patients who underwent insertion of a ventriculoperitoneal shunt for hydrocephalus after aneurysmal SAH between 2006 and 2012 were included. Patients were divided into those in whom nonprogrammable shunts and those in whom programmable shunts were inserted. The rates of shunt revisions, the reasons for adjustments of shunt settings in patients with programmable devices, and the effectiveness of the adjustments were analyzed. A cost-benefit analysis was also conducted to determine if the overall cost for programmable shunts was more than for nonprogrammable shunts. Ninety-four patients underwent insertion of shunts for hydrocephalus secondary to SAH. In 37 of these patients, nonprogrammable shunts were inserted, whereas in 57 programmable shunts were inserted. Four (7%) of 57 patients with programmable devices underwent shunt revision, whereas 8 (21.6%) of 37 patients with nonprogrammable shunts underwent shunt revision (p = 0.0413), and 4 of these patients had programmable shunts inserted during shunt revision. In 33 of 57 patients with programmable shunts, adjustments were made. The adjustments were for a trial of functional improvement (n = 21), overdrainage (n = 5), underdrainage (n = 6), or overly sunken skull defect (n = 1). Of these 33 patients, 24 showed neurological improvements (p = 0.012). Cost-benefit analysis showed $646.60 savings (US dollars) per patient if programmable shunts were used, because the cost of shunt revision is a lot higher than the cost of the shunt. The rate of shunt revision is lower in patients with programmable devices, and these are therefore more cost-effective. In addition, the shunt adjustments made for patients with programmable devices also resulted in better neurological outcomes.

  6. Biodegradable braided poly(lactic-co-glycolic acid) urethral stent combined with dutasteride in the treatment of acute urinary retention due to benign prostatic enlargement: a pilot study.

    PubMed

    Kotsar, Andres; Isotalo, Taina; Juuti, Hanne; Mikkonen, Joonas; Leppiniemi, Jenni; Hänninen, Venla; Kellomäki, Minna; Talja, Martti; Tammela, Teuvo L J

    2009-03-01

    To evaluate, in a pilot study, the efficacy and safety of combining a braided poly(lactic-co-glycolic acid) (PLGA, a copolymer of l-lactide and glycolide) urethral stent and dutasteride in the treatment of acute urinary retention (AUR) due to benign prostatic enlargement (BPE). Ten men with AUR due to BPE were treated as outpatients. A biodegradable braided PLGA urethral stent was inserted into the prostatic urethra, using a specially designed insertion device under visual control. Dutasteride treatment was started and the patients were followed up for 3 months after insertion of the stents. In all patients the stents were placed successfully with the new insertion device. All men were able to void after inserting the stent. At 1 month five patients voided freely with a low residual urine volume (<150 mL), two voided but had a high residual urine volume and a suprapubic catheter was placed, and three needed a suprapubic or an indwelling catheter before 1 month, due to AUR or comorbidities. At 3 months five patients were voiding with no problems. We have developed a new and effective insertion device for biodegradable braided prostatic stents. The new braided-pattern stent overcomes the earlier problems of migration and sudden breakage into large particles associated with biodegradable spiral stents. However, the mechanical properties of the new stent need to be improved and tested in a longer follow-up. We consider that this new biodegradable braided-pattern urethral stent could provide a new option in the future treatment of AUR.

  7. CobraPLA Insertion by anesthetists and non-anesthetists wearing unconventional protective gear: a prospective study in humans.

    PubMed

    Ben-Abraham, Ron; Flaishon, Ron; Sotman, Alexander; Ekstein, Perla; Ezri, Tiberiu; Ogorek, Daniel; Weinbroum, Avi A

    2008-07-01

    The threat of a mass casualty unconventional attack has challenged the medical community to devise means for providing rapid and reliable emergent airway control under chaotic conditions by inexperienced medical personnel dressed in self protective gear. Since endotracheal intubation may not be feasible under those conditions, other extraglottic devices should be considered. We assessed the performance of anesthesia and non-anesthesia residents in inserting the CobraPLA, a supraglottic airway device, on consecutive anesthetized patients, to assess its potential use under simulated conditions. Anesthesia and non-anesthesia residents wearing either surgical scrubs or complete anti-chemical gear inserted the CobraPLA in anesthetized patients. If post-trial positive pressure ventilation via the CobraPLA was unsuccessful, an LMA or endotracheal tube was inserted in its stead. It took anesthesia residents 57+/-23 sec and 43+/-13 sec (P<0.05) to place the CobraPLA while wearing anti-chemical gear and surgical scrubs, respectively. Non-anesthesia residents wearing anti-chemical gear performed worse than anesthetists in their first insertion (73+/-9 sec, P<0.05), but after the brief training period they performed as well as their colleagues anesthetists (58+/-10 sec, P=NS). Post-trial, twenty-one CobraPLA (42%) leaked, preventing adequate positive-pressure ventilation: 13 devices (26% of the total) required replacements. Anti-chemical protective gear slowed the insertion of the CobraPLA by anesthetists, and more so by other residents inexperienced in airway management. In 26% of the cases CobraPLA was inadequate for positive pressure ventilation.

  8. [Central venous catheter-related infections in critically ill patients].

    PubMed

    Diener, J R; Coutinho, M S; Zoccoli, C M

    1996-01-01

    To determine incidence rate, etiology and risk factors for central venous catheter (CVC)-related infections in critically-ill patients, a prospective cohort study was conducted in the general Intensive Care Unit (ICU) of a 212 bed Hospital in Florianópolis, Brazil. Patients admitted to ICU between May 1993 and February 1994, exposed to short-term CVC, were included in the study. Quantitative skin culture at CVC insertion site, semi-quantitative CVC tip culture, quantitative hub culture, and peripheral blood-culture were done. Results were submitted to univariate and multivariate analysis. Fifty-seven catheterization periods were analysed in 51 patients. The incidence rate was 21.1% (33.1 per 1,000 catheter-days) for local infection, and 8.7% (14.1 per 1,000 catheter-days) for catheter-associated bacteremia. The skin at the insertion site was colonized in 32.7% and the hub in 29.1% of the patients respectively. Potential sources of infection were the skin in 41.2% of the cases, the hub in 29.4%, remote site in 5.9% and unknown in 23.5%. The hub was implicated in 60% of the catheter-associated bacteremias. Coagulase-negative staphylococci were the main isolates. Another intravascular device and purulence at the insertion site were independently associated with local infection. Insertion at internal jugular site and hub colonization were independently associated with bacteremia. Catheter-associated bacteremia is a major complication of central venous catheterization in critically-ill patients. Internal jugular insertion and CVC hub colonization are important risk factors for significant catheter-related infections.

  9. Characterization of bacterial etiologic agents of biofilm formation in medical devices in critical care setup.

    PubMed

    Revdiwala, Sangita; Rajdev, Bhaumesh M; Mulla, Summaiya

    2012-01-01

    Background. Biofilms contaminate catheters, ventilators, and medical implants; they act as a source of disease for humans, animals, and plants. Aim. Critical care units of any healthcare institute follow various interventional strategies with use of medical devices for the management of critical cases. Bacteria contaminate medical devices and form biofilms. Material and Methods. The study was carried out on 100 positive bacteriological cultures of medical devices which were inserted in hospitalized patients. The bacterial isolates were processed as per microtitre plate. All the isolates were subjected to antibiotic susceptibility testing by VITEK 2 compact automated systems. Results. Out of the total 100 bacterial isolates tested, 88 of them were biofilm formers. A 16-20-hour incubation period was found to be optimum for biofilm development. 85% isolates were multidrug resistants and different mechanisms of bacterial drug resistance like ESBL, carbapenemase, and MRSA were found among isolates. Conclusion. Availability of nutrition in the form of glucose enhances the biofilm formation by bacteria. Time and availability of glucose are important factors for assessment of biofilm progress. It is an alarm for those who are associated with invasive procedures and indwelling medical devices especially in patients with low immunity.

  10. Method and device for supporting blood vessels during anastomosis

    DOEpatents

    Doss, J.D.

    1985-05-20

    A device and method for preventing first and second severed blood vessels from collapsing during attachment to each other. The device comprises a dissolvable non-toxic stent that is sufficiently rigid to prevent the blood vessels from collapsing during anastomosis. The stent can be hollow or have passages to permit blood flow before it dissolves. A single stent can be inserted with an end in each of the two blood vessels or separate stents can be inserted into each blood vessel. The stent may include a therapeutically effective amount of a drug which is slowly released into the blood stream as the stent dissolves. 12 figs.

  11. The use of equine chorionic gonadotropin in the treatment of anestrous dairy cows in gonadotropin-releasing hormone/progesterone protocols of 6 or 7 days.

    PubMed

    Bryan, M A; Bó, G; Mapletoft, R J; Emslie, F R

    2013-01-01

    In seasonally calving, pasture-based dairy farm systems, the interval from calving to first estrus is a critical factor affecting reproductive efficiency. This study evaluated the effects of equine chorionic gonadotropin (eCG) on the reproductive response of lactating, seasonally calving dairy cows diagnosed with anovulatory anestrus by rectal palpation. Cows on 15 commercial dairy farms were selected for initial inclusion based on nonobserved estrus by 7 d before the planned start of mating. All cows were palpated rectally and evaluated for body condition score and ovary score, and were included for treatment according to the trial protocol if diagnosed with anovulatory anestrus. All cows received a standard anestrous treatment protocol consisting of insertion of a progesterone device, injection of 100 µg of GnRH at the time of device insertion, and injection of PGF(2α) at device removal (GPG/P4). Cows were randomly assigned to 1 of 2 groups (6 d or 7 d) for duration of progesterone device insertion. Within each of these groups, cows were further randomly assigned to receive either 400 IU of eCG at device removal or to remain untreated as controls, resulting in a 2×2 arrangement of treatment groups: (1) 6-d device and no eCG (n=484); (2) 6-d device and eCG (n=462); (3) 7-d device and no eCG (n=546); and (4) 7-d device and eCG (n=499). Cows were detected for estrus from the time of progesterone device removal and were inseminated; those not detected in estrus within 60 h after progesterone device removal received 100 µg of GnRH and were inseminated at 72 h. The primary outcomes considered were proportion of cows conceiving within 7 d of the beginning of breeding (7-d conception rate; 7-d CR), proportion pregnant within 28 d (28-d in calf rate; 28-d ICR), and days to conception (DTC). We found no significant differences between the 6- and 7-d insertion periods and found no 6- or 7-d insertion period × eCG treatment interactions. Inclusion of eCG into either length of GPG/P4 protocol increased 7-d CR (36.0 vs. 30.6%) and 28-d ICR (58.6 vs. 52.3%) and decreased median days to conception. The use of eCG in GPG/P4 breeding protocols will improve reproductive efficiency in seasonally calving, anestrous dairy cattle. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  12. Lower Emittance Lattice for the Advanced Photon Source Upgrade Using Reverse Bending Magnets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borland, M.; Berenc, T.; Sun, Y.

    The Advanced Photon Source (APS) is pursuing an upgrade to the storage ring to a hybrid seven-bend-achromat design [1]. The nominal design provides a natural emittance of 67 pm [2]. By adding reverse dipole fields to several quadrupoles [3, 4] we can reduce the natural emittance to 41 pm while simultaneously providing more optimal beta functions in the insertion devices and increasing the dispersion function at the chromaticity sextupole magnets. The improved emittance results from a combination of increased energy loss per turn and a change in the damping partition. At the same time, the nonlinear dynamics performance is verymore » similar, thanks in part to increased dispersion in the sextupoles. This paper describes the properties, optimization, and performance of the new lattice.« less

  13. Dual-channel operation in a synchronously pumped optical parametric oscillator for the generation of broadband mid-infrared coherent light sources.

    PubMed

    Liu, Pei; Wang, Sicong; He, Puyuan; Zhang, Zhaowei

    2018-05-01

    We report, to the best of our knowledge, a novel approach for generating broadband mid-infrared (mid-IR) light by implementing a dual-channel scheme in a synchronously pumped optical parametric oscillator (SPOPO). Two-channel operation was achieved by inserting a prism pair and two reflection mirrors inside an optical parametric oscillator (OPO) cavity. Pumped by a Yb-fiber laser, the OPO generated an idler wave at ∼3150  nm with a -10  dB bandwidth of ∼13.2  THz, which was twice as much as that of the pump source. This scheme represents a promising technical route to transform conventional SPOPOs into a device capable of generating mid-IR light with very broad instantaneous bandwidth.

  14. Simulation of Swap-Out Reliability For The Advance Photon Source Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borland, M.

    2017-06-01

    The proposed upgrade of the Advanced Photon Source (APS) to a multibend-achromat lattice relies on the use of swap-out injection to accommodate the small dynamic acceptance, allow use of unusual insertion devices, and minimize collective effects at high single-bunch charge. This, combined with the short beam lifetime, will make injector reliability even more important than it is for top-up operation. We used historical data for the APS injector complex to obtain probability distributions for injector up-time and down-time durations. Using these distributions, we simulated several years of swap-out operation for the upgraded lattice for several operatingmodes. The results indicate thatmore » obtaining very high availability of beam in the storage ring will require improvements to injector reliability.« less

  15. Virtual Reality simulator for dental anesthesia training in the inferior alveolar nerve block.

    PubMed

    Corrêa, Cléber Gimenez; Machado, Maria Aparecida de Andrade Moreira; Ranzini, Edith; Tori, Romero; Nunes, Fátima de Lourdes Santos

    2017-01-01

    This study shows the development and validation of a dental anesthesia-training simulator, specifically for the inferior alveolar nerve block (IANB). The system developed provides the tactile sensation of inserting a real needle in a human patient, using Virtual Reality (VR) techniques and a haptic device that can provide a perceived force feedback in the needle insertion task during the anesthesia procedure. To simulate a realistic anesthesia procedure, a Carpule syringe was coupled to a haptic device. The Volere method was used to elicit requirements from users in the Dentistry area; Repeated Measures Two-Way ANOVA (Analysis of Variance), Tukey post-hoc test and averages for the results' analysis. A questionnaire-based subjective evaluation method was applied to collect information about the simulator, and 26 people participated in the experiments (12 beginners, 12 at intermediate level, and 2 experts). The questionnaire included profile, preferences (number of viewpoints, texture of the objects, and haptic device handler), as well as visual (appearance, scale, and position of objects) and haptic aspects (motion space, tactile sensation, and motion reproduction). The visual aspect was considered appropriate and the haptic feedback must be improved, which the users can do by calibrating the virtual tissues' resistance. The evaluation of visual aspects was influenced by the participants' experience, according to ANOVA test (F=15.6, p=0.0002, with p<0.01). The user preferences were the simulator with two viewpoints, objects with texture based on images and the device with a syringe coupled to it. The simulation was considered thoroughly satisfactory for the anesthesia training, considering the needle insertion task, which includes the correct insertion point and depth, as well as the perception of tissues resistances during the insertion.

  16. A novel method for percutaneous insertion of a right ventricular assist device.

    PubMed

    Avgerinos, Dimitrios V; DeBois, William; Mongero, Linda; Krieger, Karl; Salemi, Arash

    2013-06-01

    Right heart failure is a rare but often fatal complication both in the pre- and postoperative setting. Right heart support with a ventricular assist device inserted in the operating room through median sternotomy can be a time-consuming procedure that requires a reoperation for removal. In cases of urgent need of right heart support, a percutaneous technique option may be of benefit. We present our initial experience with a percutaneously inserted right ventricular assist device (RVAD) in an elderly patient with severe right heart failure. An 81-year-old female patient underwent combined aortic and mitral valve replacement at our institution. During the first postoperative evening, the patient sustained sudden cardiovascular collapse and a bedside transesophageal echocardiogram revealed severe right heart failure. A coronary angiogram showed thrombosis of the right coronary artery, which was cleared with a suction device. As a result of the patient's critical condition, it was decided that an RVAD was needed as a bridge to recovery. The patient's condition improved significantly almost immediately. Her right heart function recovered over the next few days and the RVAD was removed at the bedside. She made a complete recovery and was discharged home. This patient is a prime example that a totally RVAD can be inserted in urgent situations easily and safely under fluoroscopic and echocardiographic guidance. More clinical experience with percutaneous RVADs is required to establish this technique as an alternative equivalent to the traditional open method. Right heart failure complicates many heart diseases both in the pre- and the postoperative setting. In cases of urgent need of right heart support, a percutaneous technique of a RVAD is needed for a successful outcome. We present our initial experience with a percutaneously inserted RVAD in an elderly patient with severe postoperative right heart failure.

  17. 21 CFR 886.4300 - Intraocular lens guide.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Intraocular lens guide. 886.4300 Section 886.4300...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4300 Intraocular lens guide. (a) Identification. An intraocular lens guide is a device intended to be inserted into the eye during surgery to direct...

  18. 21 CFR 888.4230 - Cement ventilation tube.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cement ventilation tube. 888.4230 Section 888.4230...) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4230 Cement ventilation tube. (a) Identification. A cement ventilation tube is a tube-like device usually made of plastic intended to be inserted into...

  19. 21 CFR 888.4230 - Cement ventilation tube.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cement ventilation tube. 888.4230 Section 888.4230...) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4230 Cement ventilation tube. (a) Identification. A cement ventilation tube is a tube-like device usually made of plastic intended to be inserted into...

  20. 21 CFR 888.4230 - Cement ventilation tube.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cement ventilation tube. 888.4230 Section 888.4230...) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4230 Cement ventilation tube. (a) Identification. A cement ventilation tube is a tube-like device usually made of plastic intended to be inserted into...

  1. 21 CFR 888.4230 - Cement ventilation tube.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cement ventilation tube. 888.4230 Section 888.4230...) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4230 Cement ventilation tube. (a) Identification. A cement ventilation tube is a tube-like device usually made of plastic intended to be inserted into...

  2. 21 CFR 872.4880 - Intraosseous fixation screw or wire.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraosseous fixation screw or wire. 872.4880... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4880 Intraosseous fixation screw or wire. (a) Identification. An intraosseous fixation screw or wire is a metal device intended to be inserted...

  3. 21 CFR 872.4880 - Intraosseous fixation screw or wire.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Intraosseous fixation screw or wire. 872.4880... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4880 Intraosseous fixation screw or wire. (a) Identification. An intraosseous fixation screw or wire is a metal device intended to be inserted...

  4. 75 FR 52629 - Medicare Program; Establishing Additional Medicare Durable Medical Equipment, Prosthetics...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-27

    ... wheelchairs. Prosthetic devices are included in the definition of ``medical and other health services'' under section 1861(s)(8) of the Act. Prosthetic devices are defined in this section of the Act as ``devices... insertion of an intraocular lens.'' Other examples of prosthetic devices include cardiac pacemakers...

  5. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  6. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  7. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  8. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  9. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  10. 21 CFR 888.4230 - Cement ventilation tube.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cement ventilation tube. 888.4230 Section 888.4230...) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4230 Cement ventilation tube. (a) Identification. A cement ventilation tube is a tube-like device usually made of plastic intended to be inserted into...

  11. Bacteriological colonisation of uterine cavity: role of tailed intrauterine contraceptive device.

    PubMed Central

    Sparks, R A; Purrier, B G; Watt, P J; Elstein, M

    1981-01-01

    Intrauterine contraceptive devices (IUCDs) are thought to cause pelvic inflammatory disease by allowing vaginal bacteria to pass into the uterus along the tail of the device. In this study the uterine cavities of 22 women using an IUCD were examined by a multiple biopsy technique. All five uteruses with a tailless IUCD were sterile but 15 out of 17 with a tailed device contained bacteria. The bacteria had not reached the fundus and most were commensals. The bacteria were not introduced by insertion of the IUCD as bacteria were present in several cases long after insertion. No differences in bacterial count were found between monofilamentous and multifilamentous devices. Bacteria were cultured from only four devices, which suggested that the bacteria adhere to the endometrium and not to the device. The bacteria in the cavity represent interference by the tail with the protective mechanisms of the uterus, which explains the increase in pelvic inflammatory disease in IUCD users. PMID:6788128

  12. All-fiber Devices Based on Photonic Crystal Fibers with Integrated Electrodes

    NASA Astrophysics Data System (ADS)

    Chesini, Giancarlo; Cordeiro, Cristiano M. B.; de Matos, Christiano J. S.; Fokine, Michael; Carvalho, Isabel C. S.; Knighf, Jonathan C.

    2008-10-01

    A special kind of microstructured optical fiber was proposed and manufactured where, as well as the holey region (solid core and silica-air cladding), the fiber has also two large holes for electrode insertion. Bi-Sn and Au-Sn alloys were selectively inserted in those holes forming two parallel, continuous and homogeneous internal electrodes. We demonstrated the production of a monolithic device and its use to externally control some of the guidance properties (e.g. polarization) of the fiber.

  13. Prevention of Device-Related Healthcare-Associated Infections

    PubMed Central

    Septimus, Edward J.; Moody, Julia

    2016-01-01

    Healthcare-associated infections (HAIs) are a leading cause of morbidity and mortality in hospitalized patients. Up to 15% of patients develop an infection while hospitalized in the United States, which accounts for approximately 1.7 million HAIs, 99,000 deaths annually and over 10 billion dollars in costs per year. A significant percentage of HAIs are preventable using evidenced-based strategies. In terms of device-related HAIs it is estimated that 65-70% of catheter-line associated bloodstream infections (CLABSIs) and catheter-associated urinary tract infections (CAUTIs) are preventable. To prevent CLABSIs a bundle which includes hand hygiene prior to insertion and catheter manipulation, use of chlorhexidene alcohol for site preparation and maintenance, use of maximum barrier for catheter insertion, site selection, removing nonessential lines, disinfect catheter hubs before assessing line, and dressing changes are essential elements of basic practices. To prevent CAUTIs a bundle that includes hand hygiene for insertion and catheter or bag manipulation, inserting catheters for appropriate indications, insert using aseptic technique, remove catheters when no longer needed, maintain a close system keeping bag and tubing below the bladder are the key components of basic practices. PMID:26918162

  14. Safety lock-out device for electrical appliances

    DOEpatents

    Cliff, Jr., Paul L.

    1996-01-01

    A safety lock-out device prevents the insertion of an electrical power cord into an electrical power cord receptacle of an electrical appliance. The devise comprises a mounting plate fastened to the appliance and a cover plate hingedly attached to the appliance. The cover plate is movable between a first position and a second position such that, in the first position, the cover plate covers and prevents insertion of a power cord into the appliance receptacle. In said second position, the appliance receptacle is uncovered to permit insertion of a power cord into the receptacle. Extending a lock shank through aligned openings formed in flange members extending from the mounting plate and the cover plate locks the cover plate in the first position.

  15. In-office insertion of a miniaturized insertable cardiac monitor: Results from the Reveal LINQ In-Office 2 randomized study.

    PubMed

    Rogers, John D; Sanders, Prashanthan; Piorkowski, Christopher; Sohail, M Rizwan; Anand, Rishi; Crossen, Karl; Khairallah, Farhat S; Kaplon, Rachelle E; Stromberg, Kurt; Kowal, Robert C

    2017-02-01

    Recent miniaturization of an insertable cardiac monitor (ICM) may make it possible to move device insertion from a hospital to office setting. However, the safety of this strategy is unknown. The primary objective was to compare the safety of inserting the Reveal LINQ ICM in an office vs a hospital environment. Ancillary objectives included summarizing device- and procedure-related adverse events and responses to a physician questionnaire. Five hundred twenty-one patients indicated for an ICM were randomized (1:1 ratio) to undergo ICM insertion in a hospital or office environment at 26 centers in the United States in the Reveal LINQ In-Office 2 study (ClinicalTrials.gov identifier NCT02395536). Patients were followed for 90 days. ICM insertion was successful in all 482 attempted patients (office: 251; hospital: 231). The untoward event rate (composite of unsuccessful insertion and ICM- or insertion-related complications) was 0.8% (2 of 244) in the office and 0.9% (2 of 227) in the hospital (95% confidence interval, -3.0% to 2.9%; 5% noninferiority: P < .001). In addition, adverse events occurred during 2.5% (6 of 244) of office and 4.4% (10 of 227) of hospital insertions (95% confidence interval [office minus inhospital rates], -5.8% to 1.9%; 5% noninferiority: P < .001). Physicians indicated that for procedures performed in an office vs a hospital, there were fewer delays >15 minutes (16% vs 35%; P < .001) and patient response was more often "very positive." Physicians considered the office location "very convenient" more frequently than the hospital location (85% vs 27%; P < .001). The safety profile for the insertion of the Reveal LINQ ICM is excellent irrespective of insertion environment. These results may expand site of service options for LINQ insertion. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  16. A technique to control cross-field diffusion of plasma across a transverse magnetic field

    NASA Astrophysics Data System (ADS)

    Hazarika, P.; Chakraborty, M.; Das, B. K.; Bandyopadhyay, M.

    2016-12-01

    A study to control charged particle transport across a transverse magnetic field (TMF), popularly known as the magnetic filter in a negative ion source, has been carried out in a double plasma device. In the experimental setup, the TMF placed between the two magnetic cages divides the whole plasma chamber into two distinct regions, viz., the source and the target on the basis of the plasma production and the corresponding electron temperature. The plasma produced in the source region by the filament discharge method diffuses into the target region through the TMF. Data are acquired by the Langmuir probe and are compared in different source configurations, in terms of external biasing applied to metallic plates inserted in the TMF plane but in the orthogonal direction. The effect of the direction of current between the two plates in either polarity of bias in the presence of TMF on the plasma parameters and the cross-field transport of charge particles are discussed.

  17. Atlantoaxial Joint Distraction with a New Expandable Device for the Treatment of Basilar Invagination with Preservation of the C2 Nerve Root: A Cadaveric Anatomical Study.

    PubMed

    Polli, Filippo Maria; Trungu, Sokol; Miscusi, Massimo; Forcato, Stefano; Visocchi, Massimiliano; Raco, Antonino

    2017-01-01

    Atlantoaxial joint distraction has been advocated for the decompression of the brain stem in patients affected by basilar invagination, avoiding direct transoral decompression. This technique requires C2 ganglion resection and it is often impossible to perform due to the peculiar bony anatomy. We describe a cadaveric anatomical study supporting the feasibility of C1-C2 distraction performed with an expandable device, allowing easier insertion of the tool and preservation of the C2 nerve root. In five adult cadaveric specimens, posterior atlantoaxial surgical exposure was performed and an expandable system was inserted within the C1-C2 joint. The expansion of the device, leading to active distraction of the joint space, together with all the surgical steps of the technique was recorded with anatomical pictures and the final results were checked with a computed tomography (CT) scan. Insertion of the device was easily performed in all cases without anatomical conflict with the C2 ganglion; CT scans confirmed the distraction of the C1-C2 joint. This cadaveric anatomical study confirms the feasibility of the introduction of an expandable and flexible device within the C1-C2 joint, allowing it's distraction and preservation of the C2 ganglion.

  18. Tuning the Seebeck effect in C60-based hybrid thermoelectric devices through temperature-dependent surface polarization and thermally-modulated interface dipoles.

    PubMed

    Liu, Yuchun; Xu, Ling; Zhao, Chen; Shao, Ming; Hu, Bin

    2017-06-07

    Fullerene (C 60 ) is an important n-type organic semiconductor with high electron mobility and low thermal conductivity. In this work, we report the experimental results on the tunable Seebeck effect of C 60 hybrid thin-film devices by adopting different oxide layers. After inserting n-type high-dielectric constant titanium oxide (TiO x ) and zinc oxide (ZnO) layers, we observed a significantly enhanced n-type Seebeck effect in oxide/C 60 hybrid devices with Seebeck coefficients of -5.8 mV K -1 for TiO x /C 60 and -2.08 mV K -1 for ZnO/C 60 devices at 100 °C, compared with the value of -400 μV K -1 for the pristine C 60 device. However, when a p-type nickel oxide (NiO) layer is inserted, the C 60 hybrid devices show a p-type to n-type Seebeck effect transition when the temperature increases. The remarkable Seebeck effect and change in Seebeck coefficient in different oxide/C 60 hybrid devices can be attributed to two reasons: the temperature-dependent surface polarization difference and thermally-dependent interface dipoles. Firstly, the surface polarization difference due to temperature-dependent electron-phonon coupling can be enhanced by inserting an oxide layer and functions as an additional driving force for the Seebeck effect development. Secondly, thermally-dependent interface dipoles formed at the electrode/oxide interface play an important role in modifying the density of interface states and affecting the charge diffusion in hybrid devices. The surface polarization difference and interface dipoles function in the same direction in hybrid devices with TiO x and ZnO dielectric layers, leading to enhanced n-type Seebeck effect, while the surface polarization difference and interface dipoles generate the opposite impact on electron diffusion in ITO/NiO/C 60 /Al, leading to a p-type to n-type transition in the Seebeck effect. Therefore, inserting different oxide layers could effectively modulate the Seebeck effect of C 60 -based hybrid devices through the surface polarization difference and thermally-dependent interface dipoles, which represents an effective approach to tune the vertical Seebeck effect in organic functional devices.

  19. Terahertz modulation based on surface plasmon resonance by self-gated graphene

    NASA Astrophysics Data System (ADS)

    Qian, Zhenhai; Yang, Dongxiao; Wang, Wei

    2018-05-01

    We theoretically and numerically investigate the extraordinary optical transmission through a terahertz metamaterial composed of metallic ring aperture arrays. The physical mechanism of different transmission peaks is elucidated to be magnetic polaritons or propagation surface plasmons with the help of surface current and electromagnetic field distributions at respective resonance frequencies. Then, we propose a high performance terahertz modulator based on the unique PSP resonance and combined with the metallic ring aperture arrays and a self-gated parallel-plate graphene capacitor. Because, to date, few researches have exhibited gate-controlled graphene modulation in terahertz region with low insertion losses, high modulation depth and low control voltage at room temperature. Here, we propose a 96% amplitude modulation with 0.7 dB insertion losses and ∼5.5 V gate voltage. Besides, we further study the absorption spectra of the modulator. When the transmission of modulator is very low, a 91% absorption can be achieved for avoiding damaging the source devices.

  20. Photon beam position monitor

    DOEpatents

    Kuzay, Tuncer M.; Shu, Deming

    1995-01-01

    A photon beam position monitor for use in the front end of a beamline of a high heat flux and high energy photon source such as a synchrotron radiation storage ring detects and measures the position and, when a pair of such monitors are used in tandem, the slope of a photon beam emanating from an insertion device such as a wiggler or an undulator inserted in the straight sections of the ring. The photon beam position monitor includes a plurality of spaced blades for precisely locating the photon beam, with each blade comprised of chemical vapor deposition (CVD) diamond with an outer metal coating of a photon sensitive metal such as tungsten, molybdenum, etc., which combination emits electrons when a high energy photon beam is incident upon the blade. Two such monitors are contemplated for use in the front end of the beamline, with the two monitors having vertically and horizontally offset detector blades to avoid blade "shadowing". Provision is made for aligning the detector blades with the photon beam and limiting detector blade temperature during operation.

  1. Treatment of a unicameral bone cyst in a dog using a customized titanium device.

    PubMed

    Nojiri, Ayami; Akiyoshi, Hideo; Ohashi, Fumihito; Ijiri, Atsuki; Sawase, Osamu; Matsushita, Tomiharu; Takemoto, Mitsuru; Fujibayashi, Shunsuke; Nakamura, Takashi; Yamaguchi, Tsutomu

    2015-01-01

    A 4-year-old Shih-Tzu, referred for an enlarged left carpus, was diagnosed with a unicameral bone cyst. A customized titanium device was inserted into cystic lesion and fixed by titanium screws. Sufficient strength of the affected bone with the device inserted to maintain limb function was established after resection of contents of cystic lesion. There was no deterioration of the lesion of bone cyst, and acceptable function of the affected limb with no clinical signs of lameness was maintained during 36 months follow-up. The results of this study demonstrated that bone cyst curettage and use of a customized titanium device could provide an effective alternative treatment of huge lesion of unicameral bone cysts with the intent of preventing pathologic fractures.

  2. Treatment of a unicameral bone cyst in a dog using a customized titanium device

    PubMed Central

    NOJIRI, Ayami; AKIYOSHI, Hideo; OHASHI, Fumihito; IJIRI, Atsuki; SAWASE, Osamu; MATSUSHITA, Tomiharu; TAKEMOTO, Mitsuru; FUJIBAYASHI, Shunsuke; NAKAMURA, Takashi; YAMAGUCHI, Tsutomu

    2014-01-01

    ABSTRACT A 4-year-old Shih-Tzu, referred for an enlarged left carpus, was diagnosed with a unicameral bone cyst. A customized titanium device was inserted into cystic lesion and fixed by titanium screws. Sufficient strength of the affected bone with the device inserted to maintain limb function was established after resection of contents of cystic lesion. There was no deterioration of the lesion of bone cyst, and acceptable function of the affected limb with no clinical signs of lameness was maintained during 36 months follow-up. The results of this study demonstrated that bone cyst curettage and use of a customized titanium device could provide an effective alternative treatment of huge lesion of unicameral bone cysts with the intent of preventing pathologic fractures. PMID:25319515

  3. Effect of oxide insertion layer on resistance switching properties of copper phthalocyanine

    NASA Astrophysics Data System (ADS)

    Joshi, Nikhil G.; Pandya, Nirav C.; Joshi, U. S.

    2013-02-01

    Organic memory device showing resistance switching properties is a next-generation of the electrical memory unit. We have investigated the bistable resistance switching in current-voltage (I-V) characteristics of organic diode based on copper phthalocyanine (CuPc) film sandwiched between aluminum (Al) electrodes. Pronounced hysteresis in the I-V curves revealed a resistance switching with on-off ratio of the order of 85%. In order to control the charge injection in the CuPc, nanoscale indium oxide buffer layer was inserted to form Al/CuPc/In2O3/Al device. Analysis of I-V measurements revealed space charge limited switching conduction at the Al/CuPc interface. The traps in the organic layer and charge blocking by oxide insertion layer have been used to explain the absence of resistance switching in the oxide buffer layered memory device cell. Present study offer potential applications for CuPc organic semiconductor in low power non volatile resistive switching memory and logic circuits.

  4. A randomized controlled trial of nitrous oxide for intrauterine device insertion in nulliparous women.

    PubMed

    Singh, Rameet H; Thaxton, Lauren; Carr, Shannon; Leeman, Lawrence; Schneider, Emily; Espey, Eve

    2016-11-01

    To evaluate the effectiveness of inhaled nitrous oxide for pain management among nulliparous women undergoing intrauterine device (IUD) insertion. A double-blind, randomized controlled trial was conducted among nulliparous women aged 13-45years who underwent IUD insertion at a US center between October 1, 2013, and August 31, 2014. Using a computer-generated randomization sequence, participants were randomly assigned to inhale either oxygen (O 2 ) or a mixture of 50% nitrous oxide and 50% oxygen (N 2 O/O 2 ) through a nasal mask for 2minutes before insertion. Only the person administering the inhalation agent was aware of group assignment. The primary outcome was maximum pain assessed 2minutes after insertion via a 100-mm visual analog scale. Analyses were by intention to treat. Forty women were assigned to each group. Mean maximum pain score at the time of insertion was 54.3±24.8mm for the N 2 O/O 2 group and 55.3±20.9mm for the O 2 group (P=0.86). Adverse effects were reported for 6 (15%) women in the N 2 O/O 2 group and 7 (18%) in the O 2 group (P=0.32). N 2 O/O 2 did not reduce the pain of IUD insertion among nulliparous women. ClinicalTrials.gov: NCT02391714. Published by Elsevier Ireland Ltd.

  5. Radiological assessment of placement of the hysteroscopically inserted Essure permanent birth control device.

    PubMed

    Lorente Ramos, R M; Azpeitia Armán, J; Aparicio Rodríguez-Miñón, P; Salazar Arquero, F J; Albillos Merino, J C

    2015-01-01

    Essure is a permanent birth control device that is inserted through the cervix by hysteroscopy. The device is placed in the fallopian tubes, where it causes occlusion by stimulating fibrosis. Patients can be followed up with plain-film X-rays, hysterosalpingography, and ultrasonography, although the devices can also be identified incidentally on CT and MRI. The follow-up of Essure is based on checking the criteria for appropriate positioning and correct functioning (tubal occlusion) and on diagnosing complications. The most common complications are perforation, migration (toward the uterine or peritoneal cavity), and occlusion failure. In hysterosalpingography, vascular intravasation is the most common cause of diagnostic error. Radiologists need to know how to recognize the device on different imaging techniques, how to check that it is correctly placed and functioning, and how to diagnose complications. Copyright © 2014 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  6. Design and preliminary analysis of a vaginal inserter for speculum-free cervical cancer screening

    PubMed Central

    Agudogo, Júlia; Krieger, Marlee S.; Miros, Robert; Proeschold-Bell, Rae Jean; Schmitt, John W.; Ramanujam, Nimmi

    2017-01-01

    Objective Cervical cancer screening usually requires use of a speculum to provide a clear view of the cervix. The speculum is one potential barrier to screening due to fear of pain, discomfort and embarrassment. The aim of this paper is to present and demonstrate the feasibility of a tampon-sized inserter and the POCkeT Colposcope, a miniature pen sized-colposcope, for comfortable, speculum-free and potentially self-colposcopy. Study design We explored different designs using 3D computer-aided design (CAD) software and performed mechanical testing simulations on each. Designs were rapid prototyped and tested using a custom vaginal phantom across a range of vaginal pressures and uterine tilts to select an optimal design. Two final designs were tested with fifteen volunteers to assess cervix visualization, comfort and usability compared to the speculum and the optimal design, the curved-tip inserter, was selected for testing in volunteers. Results We present a vaginal inserter as an alternative to the standard speculum for use with the POCkeT Colposcope. The device has a slim tubular body with a funnel-like curved tip measuring approximately 2.5 cm in diameter. The inserter has a channel through which a 2 megapixel (MP) mini camera with LED illumination fits to enable image capture. Mechanical finite element testing simulations with an applied pressure of 15 cm H2O indicated a high factor of safety (90.9) for the inserter. Testing of the device with a custom vaginal phantom, across a range of supine vaginal pressures and uterine tilts (retroverted, anteverted and sideverted), demonstrated image capture with a visual area comparable to the speculum for a normal/axial positioned uteri and significantly better than the speculum for anteverted and sideverted uteri (p<0.00001). Volunteer studies with self-insertion and physician-assisted cervix image capture showed adequate cervix visualization for 83% of patients. In addition, questionnaire responses from volunteers indicated a 92.3% overall preference for the inserter over the speculum and all indicated that the inserter was more comfortable than the speculum. The inserter provides a platform for self-cervical cancer screening and also enables acetic acid/Lugol’s iodine application and insertion of swabs for Pap smear sample collection. Conclusion This study demonstrates the feasibility of an inserter and miniature-imaging device for comfortable cervical image capture of women with potential for synergistic HPV and Pap smear sample collection. PMID:28562669

  7. Effect of planecta and ROSE™ on the frequency characteristics of blood pressure-transducer kits.

    PubMed

    Fujiwara, Shigeki; Kawakubo, Yoshifumi; Mori, Satoshi; Tachihara, Keiichi; Toyoguchi, Izumi; Yokoyama, Takeshi

    2015-12-01

    Pressure-transducer kits have frequency characteristics such as natural frequency and damping coefficient, which affect the monitoring accuracy. The aim of the present study was to investigate the effect of planecta ports and a damping device (ROSE™, Argon Medical Devices, TX, USA) on the frequency characteristics of pressure-transducer kits. The FloTrac sensor kit (Edwards Lifesciences, CA, USA) and the DTXplus transducer kit (Argon Medical Devices) were prepared with planecta ports, and their frequency characteristics were tested with or without ROSE™. The natural frequency and damping coefficient of each kit were obtained using frequency characteristics analysis software and evaluated by plotting them on the Gardner's chart. By inserting a planecta port, the natural frequency markedly decreased in both the FloTrac sensor kit (from 40 to 22 Hz) and the DTXplus transducer kit (from 35 to 22 Hz). In both kits with one planecta port, the damping coefficient markedly increased by insertion of ROSE™ from 0.2 to 0.5, optimising frequency characteristics. In both kits with two planecta ports, however, the natural frequency decreased from 22 to 12 Hz. The damping coefficient increased from 0.2 to 0.8 by insertion of ROSE™; however, optimisation was not achieved even by ROSE™ insertion. Planecta ports decrease the natural frequency of the kit. ROSE™ is useful to optimise the frequency characteristics in the kits without or with one planecta port. However, optimisation is difficult with two or more planecta ports, even with the ROSE™ device.

  8. The complications and the position of the Codman MicroSensor™ ICP device: an analysis of 549 patients and 650 Sensors.

    PubMed

    Koskinen, Lars-Owe D; Grayson, David; Olivecrona, Magnus

    2013-11-01

    Complications of and insertion depth of the Codman MicroSensor ICP monitoring device (CMS) is not well studied. To study complications and the insertion depth of the CMS in a clinical setting. We identified all patients who had their intracranial pressure (ICP) monitored using a CMS device between 2002 and 2010. The medical records and post implantation computed tomography (CT) scans were analyzed for occurrence of infection, hemorrhage and insertion depth. In all, 549 patients were monitored using 650 CMS. Mean monitoring time was 7.0 ± 4.9 days. The mean implantation depth was 21.3 ± 11.1 mm (0-88 mm). In 27 of the patients, a haematoma was identified; 26 of these were less than 1 ml, and one was 8 ml. No clinically significant bleeding was found. There was no statistically significant increase in the number of hemorrhages in presumed coagulopathic patients. The infection rate was 0.6 % and the calculated infection rate per 1,000 catheter days was 0.8. The risk for hemorrhagic and infectious complications when using the CMS for ICP monitoring is low. The depth of insertion varies considerably and should be taken into account if patients are treated with head elevation, since the pressure is measured at the tip of the sensor. To meet the need for ICP monitoring, an intraparenchymal ICP monitoring device should be preferred to the use of an external ventricular drainage (EVD).

  9. Usefulness of a Flexible Port for Natural Orifice Transluminal Endoscopic Surgery by the Transrectal and Transvaginal Routes

    PubMed Central

    Ohdaira, Takeshi; Ikeda, Keiichi; Tajiri, Hisao; Yasuda, Yoshikazu; Hashizume, Makoto

    2010-01-01

    We developed a flexible port for NOTES which allows the use of conventional forceps for laparoscope-assisted surgery without change. The port is not affected by the location of the through hole in the gastrointestinal tract or vagina which elicits a problem in conventional NOTES, and its length can be adjusted during surgery by cutting the port itself. The port is made of polymer resin with a low friction coefficient. Furthermore, the port walls have a square wave structure which contributes to (1) the prevention of devices, for example, endoscope, from getting stuck at the time of insertion and retrieval, (2) the prevention of port slippage in the surgical opening for port insertion, (3) the prevention of unexpected port removal, (4) the prevention of port bore deformation, and (5) the improvement of port flexibility in the longitudinal direction. We validated the insertion and retrieval capacities of commercially available forceps for laparoscope-assisted surgery and power devices. Furthermore, we used the flexible port to conduct cholecystectomy and partial gastrectomy. We could confirm that the selection of the flexible port diameter according to the device type allowed the smooth insertion and retrieval of the device and that the port produced no air leakage. We affirmed that it is possible to conduct surgery by the cross or parallel method similarly to single port surgery. We considered that the flexible port has a potential of becoming a revolutionary port in NOTES. PMID:20508827

  10. 21 CFR 874.4800 - Bone particle collector.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bone particle collector. 874.4800 Section 874.4800...) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4800 Bone particle collector. (a) Identification. A bone particle collector is a filtering device intended to be inserted into a suction tube...

  11. 21 CFR 874.4800 - Bone particle collector.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Bone particle collector. 874.4800 Section 874.4800...) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4800 Bone particle collector. (a) Identification. A bone particle collector is a filtering device intended to be inserted into a suction tube...

  12. 21 CFR 874.4800 - Bone particle collector.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Bone particle collector. 874.4800 Section 874.4800...) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4800 Bone particle collector. (a) Identification. A bone particle collector is a filtering device intended to be inserted into a suction tube...

  13. 21 CFR 874.4800 - Bone particle collector.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Bone particle collector. 874.4800 Section 874.4800...) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4800 Bone particle collector. (a) Identification. A bone particle collector is a filtering device intended to be inserted into a suction tube...

  14. 21 CFR 874.4800 - Bone particle collector.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Bone particle collector. 874.4800 Section 874.4800...) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4800 Bone particle collector. (a) Identification. A bone particle collector is a filtering device intended to be inserted into a suction tube...

  15. Essure Permanent Birth Control, Effectiveness and Safety: An Italian 11-Year Survey.

    PubMed

    Franchini, Mario; Zizolfi, Brunella; Coppola, Carmela; Bergamini, Valentino; Bonin, Cecilia; Borsellino, Giovanni; Busato, Enrico; Calabrese, Stefania; Calzolari, Stefano; Fantin, Gian Piero; Giarrè, Giovanna; Litta, Piero; Luerti, Massimo; Mangino, Francesco Paolo; Marchino, Gian Luigi; Molinari, Maria Antonietta; Scatena, Elisa; Scrimin, Federica; Telloli, Paolo; Di Spiezio Sardo, Attilio

    To describe safety, tolerability, and effectiveness results through a minimum 2-year follow-up of patients who underwent permanent sterilization with the Essure insert. A retrospective multicenter study (Canadian Task Force classification II2). Seven general hospitals and 4 clinical teaching centers in Italy. A total of 1968 women, mean age 39.5 years (range, 23-48 years) who underwent office hysteroscopic sterilization using the Essure insert between April 1, 2003, and December 30, 2014. The women underwent office hysteroscopic bilateral Essure insert placement, with satisfactory device location and tube occlusion based on hysterosalpingography or hysterosalpingo-contrast sonography (HyCoSy). Placement rate, successful bilateral tubal occlusion, perioperative adverse events, early postoperative (during the first 3 months of follow-up), and late complications were evaluated. Satisfactory insertion was accomplished in 97.2% of women and, in 4, perforation and 1 expulsion were detected during hysterosalpingography. Three unintended pregnancies occurred before the 3-month confirmation test. Two pregnancies were reported among women relying on the Essure inserts. Postprocedure pain was minimal and brief; in 9 women, pelvic pain became intractable, necessitating removal of the devices via laparoscopy. On telephone interviews, overall satisfaction was rated as "very satisfied" by the majority of women (97.6%), and no long-term adverse events were reported. The findings from this extended Italian survey further support the effectiveness, tolerability, and satisfaction of Essure hysteroscopic sterilization when motivated women are selected and well informed of the potential risks of the device. Moreover, the results do not demonstrate an increased incidence of complications and pregnancies associated with long-term Essure use. Patients with a known hypersensitivity to nickel may be less suitable candidates for the Essure insert. Copyright © 2017 AAGL. Published by Elsevier Inc. All rights reserved.

  16. Coating flexible probes with an ultra fast degrading polymer to aid in tissue insertion

    PubMed Central

    Wang, Shuwu; Singh, Sagar; Damodaran, Vinod B.; Kaplan, Hilton M.; Kohn, Joachim; Shreiber, David I.; Zahn, Jeffrey D.

    2016-01-01

    We report a fabrication process for coating neural probes with an ultrafast degrading polymer to create consistent and reproducible devices for neural tissue insertion. The rigid polymer coating acts as a probe insertion aid, but resorbs within hours post-implantation. Despite the feasibility for short term neural recordings from currently available neural prosthetic devices, most of these devices suffer from long term gliosis, which isolates the probes from adjacent neurons, increasing the recording impedance and stimulation threshold. The size and stiffness of implanted probes have been identified as critical factors that lead to this long term gliosis. Smaller, more flexible probes that match the mechanical properties of brain tissue could allow better long term integration by limiting the mechanical disruption of the surrounding tissue during and after probe insertion, while being flexible enough to deform with the tissue during brain movement. However, these small flexible probes inherently lack the mechanical strength to penetrate the brain on their own. In this work, we have developed a micromolding method for coating a non-functional miniaturized SU-8 probe with an ultrafast degrading tyrosine-derived polycarbonate (E5005(2K)). Coated, non-functionalized probes of varying dimensions were reproducibly fabricated with high yields. The polymer erosion/degradation profiles of the probes were characterized in vitro. The probes were also mechanically characterized in ex vivo brain tissue models by measuring buckling and insertion forces during probe insertion. The results demonstrate the ability to produce polymer coated probes of consistent quality for future in vivo use, for example to study the effects of different design parameters that may affect tissue response during long term chronic intra-cortical microelectrode neural recordings. PMID:25681971

  17. Coating flexible probes with an ultra fast degrading polymer to aid in tissue insertion.

    PubMed

    Lo, Meng-chen; Wang, Shuwu; Singh, Sagar; Damodaran, Vinod B; Kaplan, Hilton M; Kohn, Joachim; Shreiber, David I; Zahn, Jeffrey D

    2015-04-01

    We report a fabrication process for coating neural probes with an ultrafast degrading polymer to create consistent and reproducible devices for neural tissue insertion. The rigid polymer coating acts as a probe insertion aid, but resorbs within hours post-implantation. Despite the feasibility for short term neural recordings from currently available neural prosthetic devices, most of these devices suffer from long term gliosis, which isolates the probes from adjacent neurons, increasing the recording impedance and stimulation threshold. The size and stiffness of implanted probes have been identified as critical factors that lead to this long term gliosis. Smaller, more flexible probes that match the mechanical properties of brain tissue could allow better long term integration by limiting the mechanical disruption of the surrounding tissue during and after probe insertion, while being flexible enough to deform with the tissue during brain movement. However, these small flexible probes inherently lack the mechanical strength to penetrate the brain on their own. In this work, we have developed a micromolding method for coating a non-functional miniaturized SU-8 probe with an ultrafast degrading tyrosine-derived polycarbonate (E5005(2K)). Coated, non-functionalized probes of varying dimensions were reproducibly fabricated with high yields. The polymer erosion/degradation profiles of the probes were characterized in vitro. The probes were also mechanically characterized in ex vivo brain tissue models by measuring buckling and insertion forces during probe insertion. The results demonstrate the ability to produce polymer coated probes of consistent quality for future in vivo use, for example to study the effects of different design parameters that may affect tissue response during long term chronic intra-cortical microelectrode neural recordings.

  18. Multichannel cochlear implantation in the scala vestibuli.

    PubMed

    Lin, Karen; Marrinan, Michelle S; Waltzman, Susan B; Roland, J Thomas

    2006-08-01

    Sensorineural hearing loss resulting from otosclerosis, meningitis, chronic otitis media, autoimmune ear disease, and trauma can be associated with partial or total obstruction of the cochlear scalae. Multichannel cochlear implantation may be difficult in a cochlea with an obstructed scala tympani. The purpose of this study is to determine the safety and efficacy of scala tympani electrode insertion. Retrospective chart review. Academic medical center. Eight children and adults with profound sensorineural hearing loss who underwent cochlear implantation with known scala vestibuli electrode array insertion were subjects for this study. Eight study subjects underwent implantation: five with the Nucleus 24RCS (Contour) device and three with the Nucleus 24M device. Imaging findings, operative findings, and age-appropriate speech perception testing. All patients had full electrode insertion. Various obstructive patterns on computed tomography and magnetic resonance imaging were found, and there was a range of speech perception results. All but one patient improved based on age-appropriate monosyllabic word and sentence tests. Scala vestibuli multielectrode insertion is a viable alternative when scala tympani insertion is not possible because of abnormal anatomy or anatomical changes secondary to disease or previous implantation. We will also present an algorithm of options for decision making for implantation when encountering cochlear obstruction and difficult electrode insertion.

  19. Vertically polarizing undulator with the dynamic compensation of magnetic forces for the next generation of light sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strelnikov, N.; Budker Institute of Nuclear Physics, Novosibirsk 630090; Trakhtenberg, E.

    2014-11-15

    A short prototype (847-mm-long) of an Insertion Device (ID) with the dynamic compensation of ID magnetic forces has been designed, built, and tested at the Advanced Photon Source (APS) of the Argonne National Laboratory. The ID magnetic forces were compensated by the set of conical springs placed along the ID strongback. Well-controlled exponential characteristics of conical springs permitted a very close fit to the ID magnetic forces. Several effects related to the imperfections of actual springs, their mounting and tuning, and how these factors affect the prototype performance has been studied. Finally, series of tests to determine the accuracy andmore » reproducibility of the ID magnetic gap settings have been carried out. Based on the magnetic measurements of the ID B{sub eff}, it has been demonstrated that the magnetic gaps within an operating range were controlled accurately and reproducibly within ±1 μm. Successful tests of this ID prototype led to the design of a 3-m long device based on the same concept. The 3-m long prototype is currently under construction. It represents R and D efforts by the APS toward APS Upgrade Project goals as well as the future generation of IDs for the Linac Coherent Light Source (LCLS)« less

  20. A randomized comparison of the i-gel with the self-pressurized air-Q intubating laryngeal airway in children.

    PubMed

    Kim, Min-Soo; Lee, Jae Hoon; Han, Sang Won; Im, Young Jae; Kang, Hyo Jong; Lee, Jeong-Rim

    2015-04-01

    Supraglottic airway devices with noninflatable cuff have advantages in omitting the cuff pressure monitoring and reducing potential pharyngolaryngeal complications. Typical devices without cuff inflation available in children are the i-gel and the self-pressurized air-Q intubating laryngeal airway (air-Q SP). To date, there is no comparative study between these devices in pediatric patients. The purpose of this randomized study was to compare the i-gel(™) and the self-pressurized air-Q(™) intubating laryngeal airway (air-Q SP) in children undergoing general anesthesia. Eighty children, 1-108 months of age, 7-30 kg of weight, and scheduled for elective surgery in which supraglottic airway devices would be suitable for airway management, were randomly assigned to either the i-gel or the air-Q SP. Oropharyngeal leak pressure and fiberoptic view were assessed three times as follows: after insertion and fixation of the device, 10 min after initial assessment, and after completion of surgery. We also assessed insertion parameters and complications. Insertion of the i-gel was regarded as significantly easier compared to the air-Q SP (P = 0.04). Compared to the air-Q SP group, the i-gel group had significantly higher oropharyngeal leak pressures at all measurement points and significantly lower frequencies of gastric insufflation at 10 min after initial assessment and completion of surgery. The air-Q SP group had better fiberoptic views than the i-gel group at all measurement points. Our results showed that the i-gel had easier insertion and better sealing function, and the air-Q SP provided improved fiberoptic views in children requiring general anesthesia. © 2015 John Wiley & Sons Ltd.

  1. Stepped nozzle

    DOEpatents

    Sutton, George P.

    1998-01-01

    An insert which allows a supersonic nozzle of a rocket propulsion system to operate at two or more different nozzle area ratios. This provides an improved vehicle flight performance or increased payload. The insert has significant advantages over existing devices for increasing nozzle area ratios. The insert is temporarily fastened by a simple retaining mechanism to the aft end of the diverging segment of the nozzle and provides for a multi-step variation of nozzle area ratio. When mounted in place, the insert provides the nozzle with a low nozzle area ratio. During flight, the retaining mechanism is released and the insert ejected thereby providing a high nozzle area ratio in the diverging nozzle segment.

  2. Core Vessel Insert Handling Robot for the Spallation Neutron Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Graves, Van B; Dayton, Michael J

    2011-01-01

    The Spallation Neutron Source provides the world's most intense pulsed neutron beams for scientific research and industrial development. Its eighteen neutron beam lines will eventually support up to twenty-four simultaneous experiments. Each beam line consists of various optical components which guide the neutrons to a particular instrument. The optical components nearest the neutron moderators are the core vessel inserts. Located approximately 9 m below the high bay floor, these inserts are bolted to the core vessel chamber and are part of the vacuum boundary. They are in a highly radioactive environment and must periodically be replaced. During initial SNS construction,more » four of the beam lines received Core Vessel Insert plugs rather than functional inserts. Remote replacement of the first Core Vessel Insert plug was recently completed using several pieces of custom-designed tooling, including a highly complicated Core Vessel Insert Robot. The design of this tool are discussed.« less

  3. Robot friendly probe and socket assembly

    NASA Technical Reports Server (NTRS)

    Nyberg, Karen L. (Inventor)

    1994-01-01

    A probe and socket assembly for serving as a mechanical interface between structures is presented. The assembly comprises a socket having a housing adapted for connection to a first supporting structure and a probe which is readily connectable to a second structure and is designed to be easily grappled and manipulated by a robotic device for insertion and coupling with the socket. Cooperable automatic locking means are provided on the probe shaft and socket housing for automatically locking the probe in the socket when the probe is inserted a predetermined distance. A second cooperable locking means on the probe shaft and housing are adapted for actuation after the probe has been inserted the predetermined distance. Actuation means mounted on the probe and responsive to the grip of the probe handle by a gripping device, such as a robot for conditioning the probe for insertion and are also responsive to release of the grip of the probe handle to actuate the second locking means to provide a hard lock of the probe in the socket.

  4. Spin Hall driven domain wall motion in magnetic bilayers coupled by a magnetic oxide interlayer

    NASA Astrophysics Data System (ADS)

    Liu, Yang; Furuta, Masaki; Zhu, Jian-Gang Jimmy

    2018-05-01

    mCell, previously proposed by our group, is a four-terminal magnetoresistive device with isolated write- and read-paths for all-spin logic and memory applications. A mCell requires an electric-insulating magnetic layer to couple the spin Hall driven write-path to the magnetic free layer of the read-path. Both paths are magnetic layers with perpendicular anisotropy and their perpendicularly oriented magnetization needs to be maintained with this insertion layer. We have developed a magnetic oxide (FeOx) insertion layer to serve for these purposes. We show that the FeOx insertion layer provides sufficient magnetic coupling between adjacent perpendicular magnetic layers. Resistance measurement shows that this magnetic oxide layer can act as an electric-insulating layer. In addition, spin Hall driven domain wall motion in magnetic bi-layers coupled by the FeOx insertion layer is significantly enhanced compared to that in magnetic single layer; it also requires low voltage threshold that poses possibility for power-efficient device applications.

  5. Proof-of-principle experiment of measurement-device-independent quantum key distribution with vector vortex beams

    NASA Astrophysics Data System (ADS)

    Dong, Chen; Zhao, Shang-Hong; Li, Wei; Yang, Jian

    2018-03-01

    In this paper, by combining measurement-device-independent quantum key distribution (MDI-QKD) scheme with entangled photon sources, we present a modified MDI-QKD scheme with pairs of vector vortex(VV) beams, which shows a structure of hybrid entangled entanglement corresponding to intrasystem entanglement and intersystem entanglement. The former entanglement, which is entangled between polarization and orbit angular momentum within each VV beam, is adopted to overcome the polarization misalignment associated with random rotations in quantum key distribution. The latter entanglement, which is entangled between the two VV beams, is used to perform entangled-based MDI-QKD protocol with pair of VV beams to inherit the merit of long distance. The numerical simulations show that our modified scheme can tolerate 97dB with practical detectors. Furthermore, our modified protocol only needs to insert q-plates in practical experiment.

  6. Intrauterine device for laser light diffusion and method of using the same

    DOEpatents

    Tadir, Yona; Berns, Michael W.; Svaasand, Lars O.; Tromberg, Bruce J.

    1995-01-01

    An improved device for delivery of photoenergy from a light source, such as a laser, into a uterine cavity for photodynamic therapy is comprised of a plurality of optic fibers, which are bundled together and inserted into the uterine cavity by means of a uterine cannula. The cannula is positioned within the uterine cavity at a preferred location and then withdrawn thereby allowing the plurality of optic fibers to splay or diverge one from the other within the cavity. Different portions of the distal tip of the optic fiber is provided with a light diffusing tip, the remainder being provided with a nondiffusing tip portion. The fiber optic shape, as well as the segment which is permitted to actively diffuse light through the tip, is selected in order to provide a more uniform exposure intensity of the photo energy or at least sufficient radiation directed to each segment of the uterine walls.

  7. Intrauterine device for laser light diffusion and method of using the same

    DOEpatents

    Tadir, Y.; Berns, M.W.; Svaasand, L.O.; Tromberg, B.J.

    1995-12-26

    An improved device for delivery of photoenergy from a light source, such as a laser, into a uterine cavity for photodynamic therapy is comprised of a plurality of optic fibers, which are bundled together and inserted into the uterine cavity by means of a uterine cannula. The cannula is positioned within the uterine cavity at a preferred location and then withdrawn thereby allowing the plurality of optic fibers to splay or diverge one from the other within the cavity. Different portions of the distal tip of the optic fiber is provided with a light diffusing tip, the remainder being provided with a nondiffusing tip portion. The fiber optic shape, as well as the segment which is permitted to actively diffuse light through the tip, is selected in order to provide a more uniform exposure intensity of the photo energy or at least sufficient radiation directed to each segment of the uterine walls. 5 figs.

  8. Development and testing of the rack insertion device

    NASA Technical Reports Server (NTRS)

    Strickland, G. Scott

    1995-01-01

    Installing and removing experiment racks in a Space Station Logistics Module will become a repetitive operation at Kennedy Space Center (KSC) in the near future. A Rack Insertion Device (RID) consisting of an Extendible Boom, End Effector, and Positioning Base is being developed for the task. This paper discusses the key elements of the RlD's function and design. Prototype test results for the RlD's Extendible Boom and End Effector are presented. Also discussed are future end effectors that will further enhance the RlD's Space Station processing capability.

  9. Commissioning of the synchrotron radiation protection system and beamlines frontends at NSLS-II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seletskiy, S., E-mail: seletskiy@bnl.gov; Amundsen, C.; Choi, J.

    2016-07-27

    The first eight insertion devices (IDs) at the NSLS-II were commissioned during the fall run of 2014. In this paper we discuss commissioning of the synchrotron radiation protection (SRP) system and beamline frontends (FE) for the respective IDs. We describe the diagnostics utilized if FE commissioning and a procedure that was used for the alignment of the photon beam from insertion devices in the beamline frontends. Then we discuss the current status of the SRP system and operation of the commissioned frontends.

  10. Topology optimization of two-dimensional elastic wave barriers

    NASA Astrophysics Data System (ADS)

    Van hoorickx, C.; Sigmund, O.; Schevenels, M.; Lazarov, B. S.; Lombaert, G.

    2016-08-01

    Topology optimization is a method that optimally distributes material in a given design domain. In this paper, topology optimization is used to design two-dimensional wave barriers embedded in an elastic halfspace. First, harmonic vibration sources are considered, and stiffened material is inserted into a design domain situated between the source and the receiver to minimize wave transmission. At low frequencies, the stiffened material reflects and guides waves away from the surface. At high frequencies, destructive interference is obtained that leads to high values of the insertion loss. To handle harmonic sources at a frequency in a given range, a uniform reduction of the response over a frequency range is pursued. The minimal insertion loss over the frequency range of interest is maximized. The resulting design contains features at depth leading to a reduction of the insertion loss at the lowest frequencies and features close to the surface leading to a reduction at the highest frequencies. For broadband sources, the average insertion loss in a frequency range is optimized. This leads to designs that especially reduce the response at high frequencies. The designs optimized for the frequency averaged insertion loss are found to be sensitive to geometric imperfections. In order to obtain a robust design, a worst case approach is followed.

  11. Status of PLS-II Upgrade Program

    NASA Astrophysics Data System (ADS)

    Kim, Kyung-Ryul; Wiedemann, Helmut; Park, Sung-Ju; Kim, Dong-Eon; Park, Chong-Do; Park, Sung-Soo; Kim, Seong-Hwan; Kim, Bongsoo; Namkung, Won; Nam, Sanghoon; Ree, Moonhor

    2010-06-01

    The Pohang Light Source (PLS) at the Pohang Accelerator Laboratory has been operated first at 2.0 GeV since 1995, and later was upgraded to 2.5 GeV. During this time, 6 insertion devices like undulators and multipole wigglers have been put into operation to produce special photon beams, with a total of 27 beamlines installed and 3 beamlines under construction. Recently, Korea synchrotron user's community is demanding high beam stability, higher photon energies as well as more straight sections for insertion devices in the PLS. To meet the user requirements, the PLS-II upgrade program has been launched in January, 2009, incorporating a modified chromatic version of Double Bend Achromat (DBA) to achieve almost twice as many straight sections as the current PLS with a design goal of the relatively low emittance, ɛ, of 5.9 nmṡrad. In the PLS-II, the top-up injection using full energy linac is planned for much higher stable beam as well and thus the production of hard x-ray undulator radiation of 8 to 13 keV is anticipated to allow for the successful research program namely Protein Crystallography. The PLS-II machine components of storage ring, linear accelerator and photon beamlines will be partly dismantled and reinstalled in a 6-months shutdown beginning January, 2011 and then the PLS-II upgrade be started the initial commissioning with a 100 mA beam current from July in 2011.

  12. Installation, commissioning and performance of IDs installed at ALBA

    NASA Astrophysics Data System (ADS)

    Campmany, J.; Marcos, J.; Massana, V.; Becheri, F.; Gigante, J. V.; Colldelram, C.; Ribó, Ll

    2013-03-01

    The new synchrotron light source ALBA is currently starting regular operation. Up to 6 beamlines are using light produced by Insertion Devices. There are up to four types of IDs: 2 Apple-II undulators (EU62 and EU71) operating at low energies, one conventional wiggler (MPW80) operating in the range of 2 - 20 keV, two in-vacuum undulators (IVU21) operating in the range 5 - 30 keV and a superconducting wiggler (SCW30) operating in the range of (up to) 40 keV. The main IDs characteristics, their influence on the beam dynamics and a first characterization of their light will be presented.

  13. Investigation of flows in LAPD and their relation to edge turbulence and intermittency

    NASA Astrophysics Data System (ADS)

    Schaffner, D.; Carter, T. A.; Friedman, B.; Vincena, S.; Auerbach, D. W.; Popovich, P.

    2009-11-01

    We report on measurements of spontaneous flows and turbulence in the Large Plasma Device (LAPD) at UCLA. Measurements of perpendicular and parallel flow using a six-sided Mach probe reveal edge-localized perpendicular flows. The source of this flow is under investigation and may be generated by boundary effects or turbulent processes. Particular cases where a plasma depletion zone is created, including inserting a blocking disk within the cathode region and forming a compressed column, are used to analyze the effects on plasma flows. Ultimately, the relationship between the flows, turbulence and intermittency---the formation of blobs---is sought.

  14. New developments in high pressure x-ray spectroscopy beamline at High Pressure Collaborative Access Team

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xiao, Y. M., E-mail: yxiao@carnegiescience.edu; Chow, P.; Boman, G.

    The 16 ID-D (Insertion Device - D station) beamline of the High Pressure Collaborative Access Team at the Advanced Photon Source is dedicated to high pressure research using X-ray spectroscopy techniques typically integrated with diamond anvil cells. The beamline provides X-rays of 4.5-37 keV, and current available techniques include X-ray emission spectroscopy, inelastic X-ray scattering, and nuclear resonant scattering. The recent developments include a canted undulator upgrade, 17-element analyzer array for inelastic X-ray scattering, and an emission spectrometer using a polycapillary half-lens. Recent development projects and future prospects are also discussed.

  15. 78 FR 15682 - Notification of Proposed Production Activity TTI, Inc.; Subzone 196A (Electromechanical and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-12

    ... Activity TTI, Inc.; Subzone 196A (Electromechanical and Circuit Protection Devices Production/ Kitting... electromechanical and circuit protection device production/kitting for a variety of commercial, aerospace and... for crimping, insertion/extraction, and terminal removal, and electromechanical devices (duty rates...

  16. 21 CFR 886.1800 - Schirmer strip.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... device made of filter paper or similar material intended to be inserted under a patient's lower eyelid to stimulate and evaluate formation of tears. (b) Classification. Class I (general controls). If the device is...

  17. Development of a clinical prediction rule to improve peripheral intravenous cannulae first attempt success in the emergency department and reduce post insertion failure rates: the Vascular Access Decisions in the Emergency Room (VADER) study protocol

    PubMed Central

    Carr, Peter J; Rippey, James C R; Cooke, Marie L; Bharat, Chrianna; Murray, Kevin; Higgins, Niall S; Foale, Aileen; Rickard, Claire M

    2016-01-01

    Introduction Peripheral intravenous cannula (PIVC) insertion is one of the most common clinical interventions performed in emergency care worldwide. However, factors associated with successful PIVC placement and maintenance are not well understood. This study seeks to determine the predictors of first time PIVC insertion success in emergency department (ED) and identify the rationale for removal of the ED inserted PIVC in patients admitted to the hospital ward. Reducing failed insertion attempts and improving peripheral intravenous cannulation practice could lead to better staff and patient experiences, as well as improving hospital efficiency. Methods and analysis We propose an observational cohort study of PIVC insertions in a patient population presenting to ED, with follow-up observation of the PIVC in subsequent admissions to the hospital ward. We will collect specific PIVC observational data such as; clinician factors, patient factors, device information and clinical practice variables. Trained researchers will gather ED PIVC insertion data to identify predictors of insertion success. In those admitted from the ED, we will determine the dwell time of the ED-inserted PIVC. Multivariate regression analyses will be used to identify factors associated with insertions success and PIVC failure and standard statistical validation techniques will be used to create and assess the effectiveness of a clinical predication rule. Ethics and dissemination The findings of our study will provide new evidence to improve insertion success rates in the ED setting and identify strategies to reduce premature device failure for patients admitted to hospital wards. Results will unravel a complexity of factors that contribute to unsuccessful PIVC attempts such as patient and clinician factors along with the products, technologies and infusates used. Trial registration number ACTRN12615000588594; Pre-results. PMID:26868942

  18. Development of a clinical prediction rule to improve peripheral intravenous cannulae first attempt success in the emergency department and reduce post insertion failure rates: the Vascular Access Decisions in the Emergency Room (VADER) study protocol.

    PubMed

    Carr, Peter J; Rippey, James C R; Cooke, Marie L; Bharat, Chrianna; Murray, Kevin; Higgins, Niall S; Foale, Aileen; Rickard, Claire M

    2016-02-11

    Peripheral intravenous cannula (PIVC) insertion is one of the most common clinical interventions performed in emergency care worldwide. However, factors associated with successful PIVC placement and maintenance are not well understood. This study seeks to determine the predictors of first time PIVC insertion success in emergency department (ED) and identify the rationale for removal of the ED inserted PIVC in patients admitted to the hospital ward. Reducing failed insertion attempts and improving peripheral intravenous cannulation practice could lead to better staff and patient experiences, as well as improving hospital efficiency. We propose an observational cohort study of PIVC insertions in a patient population presenting to ED, with follow-up observation of the PIVC in subsequent admissions to the hospital ward. We will collect specific PIVC observational data such as; clinician factors, patient factors, device information and clinical practice variables. Trained researchers will gather ED PIVC insertion data to identify predictors of insertion success. In those admitted from the ED, we will determine the dwell time of the ED-inserted PIVC. Multivariate regression analyses will be used to identify factors associated with insertions success and PIVC failure and standard statistical validation techniques will be used to create and assess the effectiveness of a clinical predication rule. The findings of our study will provide new evidence to improve insertion success rates in the ED setting and identify strategies to reduce premature device failure for patients admitted to hospital wards. Results will unravel a complexity of factors that contribute to unsuccessful PIVC attempts such as patient and clinician factors along with the products, technologies and infusates used. ACTRN12615000588594; Pre-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  19. The Impact of Preoperative α-Adrenergic Antagonists on Ureteral Access Sheath Insertion Force and the Upper Limit of Force Required to Avoid Ureteral Mucosal Injury: A Randomized Controlled Study.

    PubMed

    Koo, Kyo Chul; Yoon, Jun-Ho; Park, No-Cheol; Lee, Hye Sun; Ahn, Hyun Kyu; Lee, Kwang Suk; Kim, Do Kyung; Cho, Kang Su; Chung, Byung Ha; Hong, Chang Hee

    2018-06-01

    Excessive bulking force during primary access of the ureteral access sheath may induce ureteral injury. We investigated the efficacy of preoperative α-blockade to reduce ureteral access sheath insertion force and determine the upper limit required to avoid ureteral injury. In this randomized controlled trial 135 patients from a single institution who had ureteropelvic junction or renal pelvis stones and were scheduled to undergo retrograde intrarenal surgery were prospectively enrolled from December 2015 to January 2017. Of the patients 41 and 42 were randomly assigned to the control and experimental groups, respectively. The experimental group received α-blockade preoperatively. The 21 patients who were pre-stented were assessed separately. We developed a homemade device to measure maximal ureteral access sheath insertion force. Our ureteral access sheath insertion force measurement device showed excellent reproducibility. Higher insertion velocity resulted in greater maximal sheath insertion force. Maximal insertion force in the α-blockade group was significantly lower than in the control group at the ureterovesical junction (p = 0.008) and the proximal ureter (p = 0.036). Maximal insertion force in the α-blockade group was comparable to that in pre-stented patients. Female patients and patients 70 years old or older showed a lower maximal ureteral access sheath insertion force than their counterparts. The rate of grade 2 or greater ureteral injury was lower in the α-blockade group than in controls (p = 0.038). No injury occurred in any case in which ureteral access sheath insertion force did not exceed 600 G. Preoperative α-blockade and slow sheath placement may reduce maximal ureteral access sheath insertion force. If the force exceeds 600 G, a smaller diameter sheath may be an alternative. Alternatively the procedure can be terminated and followed later by pre-stented retrograde intrarenal surgery. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  20. Revolving Loan Fund: A Novel Approach to Increasing Access to Long-Acting Reversible Contraception Methods in Community Health Centers.

    PubMed

    Evans, Megan L; Breeze, Janis L; Paulus, Jessica K; Meadows, Audra

    The aim of this study was to assess the impact of a revolving loan fund (RLF) on timing of device insertion and long-acting reversible contraception (LARC) access among a high-risk urban population at 3 Boston community health centers. Three health centers were identified to implement a RLF. Each clinic received $5000 from the RLF to purchase LARC devices. Data collected through medical record review retrospectively 1 year prior to start of the RLF and prospectively for 1 year thereafter included patient demographics, type of LARC selected, patient's date of documented interest in a LARC device, and date of insertion. The effect of a RLF on delay to LARC insertion was tested using negative binomial regression, controlling for site and potential confounding variables between the pre- and post-RLF periods. Three urban community health centers. Reproductive-aged women who received family planning services at the 3 participating health centers. Increasing access to LARC and decreasing wait times to LARC insertion after implementation of the RLF. Data on 133 patients in the pre-RLF group and 205 in the post-RLF group were collected. There were no statistically significant differences in demographic or clinical characteristics between the 2 time periods. LARC uptake increased significantly from the pre- to post-RLF period, specifically among implant users. There was a statistically significant decrease in the mean number of days in delay from interest to insertion from the pre- to post-RLF period (pre-RLF: 31.3 ± 50.6 days; post-RLF: 13.6 ± 16.7 days, adjusted P < .001). The reasons for the delay did not differ significantly between the 2 time periods. The RLF decreased wait time for the devices and increased overall insertion rates. This may serve as a promising solution to improve LARC access in community health centers. This project could be expanded to include more health centers, creating a city wide RLF. This expansion could allow for further data analysis, including unintended pregnancy rates with LARC delay, LARC continuation rates, and sustainability of a RLF.

  1. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  2. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  3. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  4. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  5. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  6. Malaria rapid diagnostic kits: quality of packaging, design and labelling of boxes and components and readability and accuracy of information inserts.

    PubMed

    Gillet, Philippe; Maltha, Jessica; Hermans, Veerle; Ravinetto, Raffaella; Bruggeman, Cathrien; Jacobs, Jan

    2011-02-13

    The present study assessed malaria RDT kits for adequate and correct packaging, design and labelling of boxes and components. Information inserts were studied for readability and accuracy of information. Criteria for packaging, design, labelling and information were compiled from Directive 98/79 of the European Community (EC), relevant World Health Organization (WHO) documents and studies on end-users' performance of RDTs. Typography and readability level (Flesch-Kincaid grade level) were assessed. Forty-two RDT kits from 22 manufacturers were assessed, 35 of which had evidence of good manufacturing practice according to available information (i.e. CE-label affixed or inclusion in the WHO list of ISO13485:2003 certified manufacturers). Shortcomings in devices were (i) insufficient place for writing sample identification (n=40) and (ii) ambiguous labelling of the reading window (n=6). Buffer vial labels were lacking essential information (n=24) or were of poor quality (n=16). Information inserts had elevated readability levels (median Flesch Kincaid grade 8.9, range 7.1-12.9) and user-unfriendly typography (median font size 8, range 5-10). Inadequacies included (i) no referral to biosafety (n=18), (ii) critical differences between depicted and real devices (n=8), (iii) figures with unrealistic colours (n=4), (iv) incomplete information about RDT line interpretations (n=31) and no data on test characteristics (n=8). Other problems included (i) kit names that referred to Plasmodium vivax although targeting a pan-species Plasmodium antigen (n=4), (ii) not stating the identity of the pan-species antigen (n=2) and (iii) slight but numerous differences in names displayed on boxes, device packages and information inserts. Three CE labelled RDT kits produced outside the EC had no authorized representative affixed and the shape and relative dimensions of the CE symbol affixed did not comply with the Directive 98/79/EC. Overall, RDTs with evidence of GMP scored better compared to those without but inadequacies were observed in both groups. Overall, malaria RDTs showed shortcomings in quality of construction, design and labelling of boxes, device packages, devices and buffers. Information inserts were difficult to read and lacked relevant information.

  7. The cervical cap (image)

    MedlinePlus

    The cervical cap is a flexible rubber cup-like device that is filled with spermicide and self-inserted over the cervix ... left in place several hours after intercourse. The cap is a prescribed device fitted by a health ...

  8. A field-cancellation algorithm for constructing economical planar permanent magnet (PM) multipoles with large high-quality field apertures

    NASA Astrophysics Data System (ADS)

    Tatchyn, Roman

    1997-05-01

    In recent years studies have been initiated on a new class of multipole field generators consisting of cuboid planar permanent magnet (PM) pieces arranged in bi-planar arrays of 2-fold rotational symmetry(R. Tatchyn, "Planar Permanent Magnet Multipoles: for Particle Accelerator and Storage Ring Applications ," IEEE Trans. Mag. 30, 5050(1994).)(T. Cremer, R. Tatchyn, "Planar Permanent Magnet Multipoles: Measurements and Configurations," in Proceedings of the 1995 Particle Accelerator Conference, IEEE Catalog No. 95CH35843, paper FAQ-20.). These structures, first introduced for Free Electron Laser (FEL) applications(R. Tatchyn, "Selected applications of planar permanent magnet multipoles in FEL insertion device design," NIM A341, 449(1994).), are based on reducing the rotational symmetry of conventional N-pole field generators from N-fold to 2-fold. One consequence of this reduction is a large higher-multipole content in a planar PM multipole's field at distances relatively close to the structure's axis, making it generally unsuitable for applications requiring a large high-quality field aperture. In this paper we outline an economical field-cancellation algorithm that can substantially decrease the harmonic content of a planar PM's field without breaking its biplanar geometry or 2-fold rotational symmetry. This will enable planar PM multipoles to be employed in a broader range of applications than heretofore possible, in particular as distributed focusing elements installed in insertion device gaps on synchrotron storage rings. This accomplishment is expected to remove the conventional restriction of an insertion device's length to the scale of the local focusing beta, enabling short-period, small-gap undulators to be installed and operated as high-brightness sources on lower-energy storage rings(R. Tatchyn, P. Csonka, A. Toor, "Perspectives on micropole undulators in synchrotron radiation technology," Rev. Sci. Instrum. 60(7), 1796(1989).). Operation as ordinary focusing elements in storage ring magnetic lattices, as well as the performance of other high-quality multipole applications, should also becomes possible with the realization of the proposed structures.

  9. Analysis and Optimization of Thin Film Ferroelectric Phase Shifters

    NASA Technical Reports Server (NTRS)

    Romanofsky, Robert R.; VanKeuls, Fred W.; Warner, Joseph D.; Mueller, Carl H.; Alterovitz, Samuel A.; Miranda, Felix A.; Qureshi, A. Haq; Romanofsky, Robert R. (Technical Monitor)

    2000-01-01

    Microwave phase shifters have been fabricated from (YBa2Cu3O(7-delta) or Au)/SrTiO3 and Au/Ba(x)Sr(1-x)TiO3 films on LaAlO3 and MgO substrates. These coupled microstrip devices rival the performance of their semiconductor counter-parts parts at Ku- and K-band frequencies. Typical insertion loss for room temperature ferroelectric phase shifters at K-band is approximately equal 5 dB. An experimental and theoretical investigation of these novel devices explains the role of the ferroelectric film in overall device performance. A roadmap to the development of a 3 dB insertion loss phase shifter that would enable a new type of phased array antenna is discussed.

  10. The copper-7 intrauterine contraceptive device: 5-year evaluation.

    PubMed Central

    Sellors, J. W.

    1981-01-01

    Over a 5-year period a family practitioner inserted copper-7 (Cu-7 intrauterine contraceptive devices (IUDs) in 134 women. The rates of continued use after 2 years, 53.0% for the women's first IUD and 63.9% for all their IUDs, and of accidental pregnancy, 2.4%, are comparable to those in the literature. However, in this series the rate of expulsion was 0.8%, much lower than that in the literature. Fertility did not appear to be reduced in women who planned to have pregnancies after the device was removed. A carefully scrutinized technique of insertion and conscientious follow-up make the Cu-7 IUD an acceptable form of contraception for many patients in a family practice. PMID:7326653

  11. Techniques for the insertion of the ProSeal laryngeal mask airway: comparison of the Foley airway stylet tool with the introducer tool in a prospective, randomized study.

    PubMed

    Chen, Mao-Kai; Hsu, Hung-Te; Lu, I-Cheng; Shih, Chih-Kai; Shen, Ya-Chun; Tseng, Kuang-Yi; Cheng, Kuang-I

    2014-01-01

    Many tools have been developed to facilitate the insertion of the ProSeal laryngeal mask airway (LMA) insertion, which can be impeded by folding of its soft cuff. The aim of this study was to compare the efficiency of ProSeal LMA insertion guided by a soft, direct optical Foley Airway Stylet Tool (FAST) with the standard introducer tool (IT). One hundred sixty patients undergoing general anesthesia using the ProSeal LMA as an airway management device were randomly allocated to either FAST-guided or IT-assisted groups. Following ProSeal LMA insertion, the glottic and esophageal openings were identified using a fiberoptic bronchoscope introduced through the airway and the drain tube. The primary outcomes were time taken to insert the ProSeal LMA and the success rate at the first attempt. Secondary end points included ease of insertion, hemodynamic response to insertion, and postoperative adverse events recorded in the recovery room and on the first postoperative morning. One hundred forty patients were included in the final analysis: 66 in the FAST-guided group and 74 in the IT-assisted group. The success rate of FAST device-guided ProSeal LMA insertion (95.7%) was broadly comparable with IT-assisted insertion (98.7%). However, the time taken to insert the ProSeal LMA was significantly longer when the FAST technique was used (p <0.001). The incidence of correct alignment of the airway tube and the drain tube did not differ significantly between the groups. There were no significant differences in ease of insertion or hemodynamic responses to insertion, except that the incidence of postoperative sore throat was significantly higher in the FAST group on the first postoperative day (22.2% compared with 6.8% in the IT group; p = 0.035). Both FAST-guided and IT-assisted techniques achieved correct ProSeal LMA positioning, but the IT technique was significantly quicker and less likely to cause a sore throat. ClinicalTrials.gov Identifier: NCT02048657.

  12. Interactive Near-Field Illumination for Photorealistic Augmented Reality with Varying Materials on Mobile Devices.

    PubMed

    Rohmer, Kai; Buschel, Wolfgang; Dachselt, Raimund; Grosch, Thorsten

    2015-12-01

    At present, photorealistic augmentation is not yet possible since the computational power of mobile devices is insufficient. Even streaming solutions from stationary PCs cause a latency that affects user interactions considerably. Therefore, we introduce a differential rendering method that allows for a consistent illumination of the inserted virtual objects on mobile devices, avoiding delays. The computation effort is shared between a stationary PC and the mobile devices to make use of the capacities available on both sides. The method is designed such that only a minimum amount of data has to be transferred asynchronously between the participants. This allows for an interactive illumination of virtual objects with a consistent appearance under both temporally and spatially varying real illumination conditions. To describe the complex near-field illumination in an indoor scenario, HDR video cameras are used to capture the illumination from multiple directions. In this way, sources of illumination can be considered that are not directly visible to the mobile device because of occlusions and the limited field of view. While our method focuses on Lambertian materials, we also provide some initial approaches to approximate non-diffuse virtual objects and thereby allow for a wider field of application at nearly the same cost.

  13. Navigating conjugated polymer actuated neural probes in a brain phantom

    NASA Astrophysics Data System (ADS)

    Daneshvar, Eugene D.; Kipke, Daryl; Smela, Elisabeth

    2012-04-01

    Neural probe insertion methods have a direct impact on the longevity of the device in the brain. Initial tissue and vascular damage caused by the probe entering the brain triggers a chronic tissue response that is known to attenuate neural recordings and ultimately encapsulate the probes. Smaller devices have been found to evoke reduced inflammatory response. One way to record from undamaged neural networks may be to position the electrode sites away from the probe. To investigate this approach, we are developing probes with controllably movable electrode projections, which would move outside of the zone that is damaged by the insertion of the larger probe. The objective of this study was to test the capability of conjugated polymer bilayer actuators to actuate neural electrode projections from a probe shank into a transparent brain phantom. Parylene neural probe devices, having five electrode projections with actuating segments and with varying widths (50 - 250 μm) and lengths (200 - 1000 μm) were fabricated. The electroactive polymer polypyrrole (PPy) was used to bend or flatten the projections. The devices were inserted into the brain phantom using an electronic microdrive while simultaneously activating the actuators. Deflections were quantified based on video images. The electrode projections were successfully controlled to either remain flat or to actuate out-of-plane and into the brain phantom during insertion. The projection width had a significant effect on their ability to deflect within the phantom, with thinner probes deflecting but not the wider ones. Thus, small integrated conjugated polymer actuators may enable multiple neuro-experiments and applications not possible before.

  14. Treatment of congenital anophthalmos with self-inflating polymer expanders: a new method.

    PubMed

    Wiese, K G; Vogel, M; Guthoff, R; Gundlach, K K

    1999-04-01

    Congenital anophthalmos is a rare malformation in which the optic vesicle fails to develop. This leads to a small bony orbit, a constricted mucosal socket, short eyelids, reduced palpebral fissure and malar hypoplasia. The treatment includes both aesthetic and functional aspects. Therefore, a two-step procedure is described using a new self-inflating hydrogel expander. A lens-shaped expander with a diameter of 8 mm expands the lids and the mucosal socket to allow insertion of an eye prosthesis. As a second step, orbital expansion is performed with a spherical device. The expanders absorb lacrimal fluid from the mucosal socket or tissue fluid and start swelling when implanted in the orbital tissue. The insertion of an expander into the orbit as well as into the conjunctival pocket including its fixation by a single suture took only a few minutes and was an easy procedure. The expansion of the small conjunctival sockets was successfully completed in all cases within a period of 2-4 weeks. The weight (= volume in ml) of devices increased from 0.15-1.5 g (lens-shaped expander; weight in grams = volume in ml) respectively, 0.3-3.5 g (spherical device). The expanders inserted in orbital tissue increased from 0.4-4.4 g. This is equivalent to a 10 to 11 fold increase in their water-free volumes. Orbital expansion with spherical devices in combination with the inserted eye prosthesis enlarges the lid and palpebral fissures also. In contrast to conventional silicon balloon expanders, the procedure using self-inflating hydrogel expanders is simple and highly efficient.

  15. Stepped nozzle

    DOEpatents

    Sutton, G.P.

    1998-07-14

    An insert is described which allows a supersonic nozzle of a rocket propulsion system to operate at two or more different nozzle area ratios. This provides an improved vehicle flight performance or increased payload. The insert has significant advantages over existing devices for increasing nozzle area ratios. The insert is temporarily fastened by a simple retaining mechanism to the aft end of the diverging segment of the nozzle and provides for a multi-step variation of nozzle area ratio. When mounted in place, the insert provides the nozzle with a low nozzle area ratio. During flight, the retaining mechanism is released and the insert ejected thereby providing a high nozzle area ratio in the diverging nozzle segment. 5 figs.

  16. Use of peripherally inserted central venous catheters (PICCs) in children receiving autologous or allogeneic stem-cell transplantation.

    PubMed

    Benvenuti, Stefano; Ceresoli, Rosanna; Boroni, Giovanni; Parolini, Filippo; Porta, Fulvio; Alberti, Daniele

    2018-03-01

    The aim of our study was to present our experience with the use of peripherally inserted central catheters (PICCs) in pediatric patients receiving autologous or allogenic blood stem-cell transplantation. The insertion of the device in older children does not require general anesthesia and does not require a surgical procedure. From January 2014 to January 2017, 13 PICCs were inserted as a central venous device in 11 pediatric patients submitted to 14 autologous or allogeneic stem-cell transplantation, at the Bone Marrow Transplant Unit of the Children's Hospital of Brescia. The mean age of patients at the time of the procedure was 11.3 years (range 3-18 years). PICCs remained in place for an overall period of 4104 days. All PICCs were positioned by the same specifically trained physician and utilized by nurses of our stem-cell transplant unit. No insertion-related complications were observed. Late complications were catheter ruptures and line occlusions (1.2 per 1000 PICC days). No rupture or occlusion required removal of the device. No catheter-related venous thrombosis, catheter-related bloodstream infection (CRBSI), accidental removal or permanent lumen occlusion were observed. Indications for catheter removal were completion of therapy (8 patients) and death (2 patients). Three PICCs are currently being used for blood sampling in follow-up patients after transplantation. Our data suggest that PICCs are a safe and effective alternative to conventional central venous catheters even in pediatric patients with high risk of infectious and hemorrhagic complications such as patients receiving stem-cell transplantation.

  17. Chronic behavior evaluation of a micro-machined neural implant with optimized design based on an experimentally derived model.

    PubMed

    Andrei, Alexandru; Welkenhuysen, Marleen; Ameye, Lieveke; Nuttin, Bart; Eberle, Wolfgang

    2011-01-01

    Understanding the mechanical interactions between implants and the surrounding tissue is known to have an important role for improving the bio-compatibility of such devices. Using a recently developed model, a particular micro-machined neural implant design aiming the reduction of insertion forces dependence on the insertion speed was optimized. Implantations with 10 and 100 μm/s insertion speeds showed excellent agreement with the predicted behavior. Lesion size, gliosis (GFAP), inflammation (ED1) and neuronal cells density (NeuN) was evaluated after 6 week of chronic implantation showing no insertion speed dependence.

  18. Strategies to improve electrode positioning and safety in cochlear implants.

    PubMed

    Rebscher, S J; Heilmann, M; Bruszewski, W; Talbot, N H; Snyder, R L; Merzenich, M M

    1999-03-01

    An injection-molded internal supporting rib has been produced to control the flexibility of silicone rubber encapsulated electrodes designed to electrically stimulate the auditory nerve in human subjects with severe to profound hearing loss. The rib molding dies, and molds for silicone rubber encapsulation of the electrode, were designed and machined using AutoCad and MasterCam software packages in a PC environment. After molding, the prototype plastic ribs were iteratively modified based on observations of the performance of the rib/silicone composite insert in a clear plastic model of the human scala tympani cavity. The rib-based electrodes were reliably inserted farther into these models, required less insertion force and were positioned closer to the target auditory neural elements than currently available cochlear implant electrodes. With further design improvements the injection-molded rib may also function to accurately support metal stimulating contacts and wire leads during assembly to significantly increase the manufacturing efficiency of these devices. This method to reliably control the mechanical properties of miniature implantable devices with multiple electrical leads may be valuable in other areas of biomedical device design.

  19. Photonic lantern with multimode fibers embedded

    NASA Astrophysics Data System (ADS)

    Yu, Hai-Jiao; Yan, Qi; Huang, Zong-Jun; Tian, He; Jiang, Yu; Liu, Yong-Jun; Zhang, Jian-Zhong; Sun, Wei-Min

    2014-08-01

    A photonic lantern is studied which is formed by seven multimode fibers inserted into a pure silica capillary tube. The core of the tapered end has a uniform refractive index because the polymer claddings are removed before the fibers are inserted. Consequently, the light distribution is also uniform. Two theories describing a slowly varying waveguide and multimode coupling are used to analyze the photonic lantern. The transmission loss decreases as the length of the tapered part increases. For a device with a taper length of 3.4 cm, the loss is about 1.06 dB on average for light propagating through the taper from an inserted fiber to the tapered end and 0.99 dB in the reverse direction. For a device with a taper length of 0.7 cm, the two loss values are 2.63 dB and 2.53 dB, respectively. The results show that it is possible to achieve a uniform light distribution with the tapered end and a low-loss transmission in the device if parameters related to the lantern are reasonably defined.

  20. USB Storage Device Forensics for Windows 10.

    PubMed

    Arshad, Ayesha; Iqbal, Waseem; Abbas, Haider

    2018-05-01

    Significantly increased use of USB devices due to their user-friendliness and large storage capacities poses various threats for many users/companies in terms of data theft that becomes easier due to their efficient mobility. Investigations for such data theft activities would require gathering critical digital information capable of recovering digital forensics artifacts like date, time, and device information. This research gathers three sets of registry and logs data: first, before insertion; second, during insertion; and the third, after removal of a USB device. These sets are analyzed to gather evidentiary information from Registry and Windows Event log that helps in tracking a USB device. This research furthers the prior research on earlier versions of Microsoft Windows and compares it with latest Windows 10 system. Comparison of Windows 8 and Windows 10 does not show much difference except for new subkey under USB Key in registry. However, comparison of Windows 7 with latest version indicates significant variances. © 2017 American Academy of Forensic Sciences.

  1. A minimally invasive method for extraction of sturgeon oocytes

    USGS Publications Warehouse

    Candrl, James S.; Papoulias, Diana M.; Tillitt, Donald E.

    2010-01-01

    Fishery biologists, hatchery personnel, and caviar fishers routinely extract oocytes from sturgeon (Acipenseridae) to determine the stage of maturation by checking egg quality. Typically, oocytes are removed either by inserting a catheter into the oviduct or by making an incision in the body cavity. Both methods can be time-consuming and stressful to the fish. We describe a device to collect mature oocytes from sturgeons quickly and effectively with minimal stress on the fish. The device is made by creating a needle from stainless steel tubing and connecting it to a syringe with polyvinyl chloride tubing. The device is filled with saline solution or water, the needle is inserted into the abdominal wall, and eggs are extracted from the fish. Using this device, an oocyte sample can be collected in less than 30 s. Such sampling leaves a minute wound that heals quickly and does not require suturing. The extractor device can easily be used in the field or hatchery, reduces fish handling time, and minimizes stress.

  2. Miniature Wireless BioSensor for Remote Endoscopic Monitoring

    NASA Astrophysics Data System (ADS)

    Nemiroski, Alex; Brown, Keith; Issadore, David; Westervelt, Robert; Thompson, Chris; Obstein, Keith; Laine, Michael

    2009-03-01

    We have built a miniature wireless biosensor with fluorescence detection capability that explores the miniaturization limit for a self-powered sensor device assembled from the latest off-the-shelf technology. The device is intended as a remote medical sensor to be inserted endoscopically and remainin a patient's gastrointestinal tract for a period of weeks, recording and transmitting data as necessary. A sensing network may be formed by using multiple such devices within the patient, routing information to an external receiver that communicates through existing mobilephone networks to relay data remotely. By using a monolithic IC chip with integrated processor, memory, and 2.4 GHz radio,combined with a photonic sensor and miniature battery, we have developed a fully functional computing device in a form factorcompliantwith insertion through the narrowest endoscopic channels (less than 3mm x 3mm x 20mm). We envision similar devices with various types of sensors to be used in many different areas of the human body.

  3. Plantar Fibroma

    MedlinePlus

    ... size. Orthotic devices. If the fibroma is stable, meaning it is not changing in size, custom orthotic devices (shoe inserts) may relieve the pain by distributing the patient’s weight away from the fibroma. Physical therapy. The pain is sometimes treated through physical ...

  4. Brazing copper to dispersion-strengthened copper

    NASA Astrophysics Data System (ADS)

    Ryding, David G.; Allen, Douglas; Lee, Richard H.

    1996-11-01

    The advanced photon source is a state-of-the-art synchrotron light source that will produce intense x-ray beams, which will allow the study of smaller samples and faster reactions and processes at a greater level of detail than has ben possible to date. The beam is produced by using third- generation insertion devices in a 7-GeV electron/positron storage ring that is 1,104 meters in circumference. The heat load from these intense high-power devices is very high, and certain components must sustain total heat loads of 3 to 15 kW and heat fluxes of 30 W/mm$_2). Because the beams will cycle on and off many times, thermal shock and fatigue will be a problem. High heat flux impinging on a small area causes a large thermal gradient that results in high stress. GlidCop, a dispersion-strengthened copper, is the desired design material because of its high thermal conductivity and superior mechanical properties as compared to copper and its alloys. GlidCop is not amenable to joining by fusion welding, and brazing requires diligence because of high diffusivity. Brazing procedures were developed using optical and scanning electron microscopy.

  5. Hysteroscopic sterilization of patient with intrauterine device Mirena®

    PubMed Central

    Depes, Daniella De Batista; Pereira, Ana Maria Gomes; Yatabe, Salete; Lopes, Reginaldo Guedes Coelho

    2013-01-01

    ABSTRACT Tubal sterilization is the definitive procedure most often used worldwide to control fecundity. Laparoscopic ligature is safe, but invasive and with possible surgical and anesthetic risks. The hysteroscopic approach enables tubal occlusion at outpatient's setting without the need of incisions or anesthesia. A microdevice (Essure®) is inserted directly into the tubes and its polyethelene fibers cause obstruction of tubes in about three months. During this period, it is recommended that patients continue the use of a temporary birth control method. Several women use the levonorgestrel-releasing intrauterine system, which is called in the market as Mirena®. This report evaluated the possibility of inserting Essure® without remove the intrauterine device; patient tolerance to the procedure was also assessed. The tubal device was successfully placed in the patient without the need to remove Mirena®. After three months the intrauterine device was removed with no intercurrent events. PMID:23579753

  6. An MRI-Guided Telesurgery System Using a Fabry-Perot Interferometry Force Sensor and a Pneumatic Haptic Device.

    PubMed

    Su, Hao; Shang, Weijian; Li, Gang; Patel, Niravkumar; Fischer, Gregory S

    2017-08-01

    This paper presents a surgical master-slave teleoperation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. The slave robot consists of a piezoelectrically actuated 6-degree-of-freedom (DOF) robot for needle placement with an integrated fiber optic force sensor (1-DOF axial force measurement) using the Fabry-Perot interferometry (FPI) sensing principle; it is configured to operate inside the bore of the MRI scanner during imaging. By leveraging the advantages of pneumatic and piezoelectric actuation in force and position control respectively, we have designed a pneumatically actuated master robot (haptic device) with strain gauge based force sensing that is configured to operate the slave from within the scanner room during imaging. The slave robot follows the insertion motion of the haptic device while the haptic device displays the needle insertion force as measured by the FPI sensor. Image interference evaluation demonstrates that the telesurgery system presents a signal to noise ratio reduction of less than 17% and less than 1% geometric distortion during simultaneous robot motion and imaging. Teleoperated needle insertion and rotation experiments were performed to reach 10 targets in a soft tissue-mimicking phantom with 0.70 ± 0.35 mm Cartesian space error.

  7. Inverse Compton scattering X-ray source yield optimization with a laser path folding system inserted in a pre-existent RF linac

    NASA Astrophysics Data System (ADS)

    Chaleil, A.; Le Flanchec, V.; Binet, A.; Nègre, J. P.; Devaux, J. F.; Jacob, V.; Millerioux, M.; Bayle, A.; Balleyguier, P.; Prazeres, R.

    2016-12-01

    An inverse Compton scattering source is under development at the ELSA linac of CEA, Bruyères-le-Châtel. Ultra-short X-ray pulses are produced by inverse Compton scattering of 30 ps-laser pulses by relativistic electron bunches. The source will be able to operate in single shot mode as well as in recurrent mode with 72.2 MHz pulse trains. Within this framework, an optical multipass system that multiplies the number of emitted X-ray photons in both regimes has been designed in 2014, then implemented and tested on ELSA facility in the course of 2015. The device is described from both geometrical and timing viewpoints. It is based on the idea of folding the laser optical path to pile-up laser pulses at the interaction point, thus increasing the interaction probability. The X-ray output gain measurements obtained using this system are presented and compared with calculated expectations.

  8. Trace element abundance determinations by Synchrotron X Ray Fluorescence (SXRF) on returned comet nucleus mineral grains

    NASA Technical Reports Server (NTRS)

    Flynn, G. J.; Sutton, S. R.

    1989-01-01

    Trace element analyses were performed on bulk cosmic dust particles by Proton Induced X Ray Emission (PIXE) and Synchrotron X Ray Fluorescence (SXRF). When present at or near chondritic abundances the trace elements K, Ti, Cr, Mn, Cu, Zn, Ga, Ge, Se, and Br are presently detectable by SXRF in particles of 20 micron diameter. Improvements to the SXRF analysis facility at the National Synchrotron Light Source presently underway should increase the range of detectable elements and permit the analysis of smaller samples. In addition the Advanced Photon Source will be commissioned at Argonne National Laboratory in 1995. This 7 to 8 GeV positron storage ring, specifically designed for high-energy undulator and wiggler insertion devices, will be an ideal source for an x ray microprobe with one micron spatial resolution and better than 100 ppb elemental sensitivity for most elements. Thus trace element analysis of individual micron-sized grains should be possible by the time of the comet nucleus sample return mission.

  9. Aethalometer

    DOEpatents

    Hansen, Anthony D.

    1990-01-01

    An improved aethalometer (10) having a single light source (18) and a single light detector (20) and two light paths (21, 22) from the light source (18) to the light detector (20). A quartz fiber filter (13) is inserted in the device, the filter (13) having a collection area (23) in one light path (21) and a reference area (24) in the other light path (22). A gas flow path (46) through the aethalometer housing (11) allows ambient air to flow through the collection area (23) of the filter (13) so that aerosol particles can be collected on the filter. A rotating disk (31) with an opening (33) therethrough allows light for the light source (18) to pass alternately through the two light paths (21, 22). The voltage output of the detector (20) is applied to a VCO (52) and the VCO pulses for light transmission separately through the two light paths (21, 22 ) are counted and compared to determine the absorption coefficient of the collected aerosol particles.

  10. Measurement of impulse peak insertion loss for four hearing protection devices in field conditions

    PubMed Central

    Murphy, William J.; Flamme, Gregory A.; Meinke, Deanna K.; Sondergaard, Jacob; Finan, Donald S.; Lankford, James E.; Khan, Amir; Vernon, Julia; Stewart, Michael

    2015-01-01

    Objective In 2009, the U.S. Environmental Protection Agency (EPA) proposed an impulse noise reduction rating (NRR) for hearing protection devices based upon the impulse peak insertion loss (IPIL) methods in the ANSI S12.42-2010 standard. This study tests the ANSI S12.42 methods with a range of hearing protection devices measured in field conditions. Design The method utilizes an acoustic test fixture and three ranges for impulse levels: 130–134, 148–152, and 166–170 dB peak SPL. For this study, four different models of hearing protectors were tested: Bilsom 707 Impact II electronic earmuff, E·A·R Pod Express, E·A·R Combat Arms version 4, and the Etymotic Research, Inc. Electronic BlastPLG™ EB1. Study sample Five samples of each protector were fitted on the fixture or inserted in the fixture's ear canal five times for each impulse level. Impulses were generated by a 0.223 caliber rifle. Results The average IPILs increased with peak pressure and ranged between 20 and 38 dB. For some protectors, significant differences were observed across protector examples of the same model, and across insertions. Conclusions The EPA's proposed methods provide consistent and reproducible results. The proposed impulse NRR rating should utilize the minimum and maximum protection percentiles as determined by the ANSI S12.42-2010 methods. PMID:22176308

  11. X-ray grating interferometer for materials-science imaging at a low-coherent wiggler source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herzen, Julia; Physics Department and Institute for Medical Engineering, Technische Universitaet Muenchen, 85748 Garching; Donath, Tilman

    2011-11-15

    X-ray phase-contrast radiography and tomography enable to increase contrast for weakly absorbing materials. Recently, x-ray grating interferometers were developed that extend the possibility of phase-contrast imaging from highly brilliant radiation sources like third-generation synchrotron sources to non-coherent conventional x-ray tube sources. Here, we present the first installation of a three grating x-ray interferometer at a low-coherence wiggler source at the beamline W2 (HARWI II) operated by the Helmholtz-Zentrum Geesthacht at the second-generation synchrotron storage ring DORIS (DESY, Hamburg, Germany). Using this type of the wiggler insertion device with a millimeter-sized source allows monochromatic phase-contrast imaging of centimeter sized objects withmore » high photon flux. Thus, biological and materials-science imaging applications can highly profit from this imaging modality. The specially designed grating interferometer currently works in the photon energy range from 22 to 30 keV, and the range will be increased by using adapted x-ray optical gratings. Our results of an energy-dependent visibility measurement in comparison to corresponding simulations demonstrate the performance of the new setup.« less

  12. Enhancing pseudocapacitive charge storage in polymer templated mesoporous materials.

    PubMed

    Rauda, Iris E; Augustyn, Veronica; Dunn, Bruce; Tolbert, Sarah H

    2013-05-21

    Growing global energy demands coupled with environmental concerns have increased the need for renewable energy sources. For intermittent renewable sources like solar and wind to become available on demand will require the use of energy storage devices. Batteries and supercapacitors, also known as electrochemical capacitors (ECs), represent the most widely used energy storage devices. Supercapacitors are frequently overlooked as an energy storage technology, however, despite the fact that these devices provide greater power, much faster response times, and longer cycle life than batteries. Their limitation is that the energy density of ECs is significantly lower than that of batteries, and this has limited their potential applications. This Account reviews our recent work on improving pseudocapacitive energy storage performance by tailoring the electrode architecture. We report our studies of mesoporous transition metal oxide architectures that store charge through surface or near-surface redox reactions, a phenomenon termed pseudocapacitance. The faradaic nature of pseudocapacitance leads to significant increases in energy density and thus represents an exciting future direction for ECs. We show that both the choice of material and electrode architecture is important for producing the ideal pseudocapacitor device. Here we first briefly review the current state of electrode architectures for pseudocapacitors, from slurry electrodes to carbon/metal oxide composites. We then describe the synthesis of mesoporous films made with amphiphilic diblock copolymer templating agents, specifically those optimized for pseudocapacitive charge storage. These include films synthesized from nanoparticle building blocks and films made from traditional battery materials. In the case of more traditional battery materials, we focus on using flexible architectures to minimize the strain associated with lithium intercalation, that is, the accumulation of lithium ions or atoms between the layers of cathode or anode materials that occurs as batteries charge and discharge. Electrochemical analysis of these mesoporous films allows for a detailed understanding of the origin of charge storage by separating capacitive contributions from traditional diffusion-controlled intercalation processes. We also discuss methods to separate the two contributions to capacitance: double-layer capacitance and pseudocapacitance. Understanding these contributions should allow the selection of materials with an optimized architecture that maximize the contribution from pseudocapacitance. From our studies, we show that nanocrystal-based nanoporous materials offer an architecture optimized for high levels of redox or surface pseudocapacitance. Interestingly, in some cases, materials engineered to minimize the strain associated with lithium insertion can also show intercalation pseudocapacitance, which is a process where insertion processes become so kinetically facile that they appear capacitive. Finally, we conclude with a summary of simple design rules that should result in high-power, high-energy-density electrode architectures. These design rules include assembling small, nanosized building blocks to maximize electrode surface area; maintaining an interconnected, open mesoporosity to facilitate solvent diffusion; seeking flexibility in electrode structure to facilitate volume expansion during lithium insertion; optimizing crystalline domain size and orientation; and creating effective electron transport pathways.

  13. Borescope Device Takes Impressions In Ducts

    NASA Technical Reports Server (NTRS)

    Walter, Richard F.; Turner, Laura J.

    1990-01-01

    Maneuverable device built around borescope equipped to make impression molds of welded joints in interior surfaces of ducts. Molds then examined to determine degress of mismatch in welds. Inserted in duct, and color-coded handles on ends of cables used to articulate head to maneuver around corners. Use of device fairly easy and requires little training.

  14. Insertion of a pentacene layer into the gold/poly(methyl methacrylate)/heavily doped p-type Si/indium device leading to the modulation of resistive switching characteristics

    NASA Astrophysics Data System (ADS)

    Hung, Cheng-Chun; Lin, Yow-Jon

    2018-01-01

    In order to get a physical insight into the pentacene interlayer-modulated resistive switching (RS) characteristics, the Au/pentacene/poly(methyl methacrylate) (PMMA)/heavily doped p-type Si (p+-Si)/In and Au/PMMA/p+-Si/In devices are fabricated and the device performance is provided. The Au/pentacene/PMMA/p+-Si/In device shows RS behavior, whereas the Au/PMMA/p+-Si/In device exhibits the set/reset-free hysteresis current-voltage characteristics. The insertion of a pentacene layer is a noticeable contribution to the RS characteristic. This is because of the occurrence of carrier accumulation/depletion in the pentacene interlayer. The transition from carrier depletion to carrier accumulation (carrier accumulation to carrier depletion) in pentacene occurring under negative (positive) voltage induces the process of set (reset). The switching conduction mechanism is primarily described as space charge limited conduction according to the electrical transport properties measurement. The concept of a pentacene/PMMA heterostructure opens a promising direction for organic memory devices.

  15. An intraocular micro light-emitting diode device for endo-illumination during pars plana vitrectomy.

    PubMed

    Koelbl, Philipp S; Lingenfelder, Christian; Spraul, Christoph W; Kampmeier, Juergen; Koch, Frank Hj; Kim, Yong Keun; Hessling, Martin

    2018-03-01

    Development of a new, fiber-free, single-use endo-illuminator for pars plana vitrectomy as a replacement for fiber-based systems with external light sources. The hand-guided intraocularly placed white micro light-emitting diode is evaluated for its illumination properties and potential photochemical and thermal hazards. A micro light-emitting diode was used to develop a single-use intraocular illumination system. The light-source-on-tip device was implemented in a prototype with 23G trocar compatible outer diameter of 0.6 mm. The experimental testing was performed on porcine eyes. All calculations of possible photochemical and thermal hazards during the application of the intraocular micro light-emitting diode were calculated according to DIN EN ISO 15007-2: 2014. The endo-illuminator generated a homogeneous and bright illumination of the intraocular space. The color impression was physiologic and natural. Contrary to initial apprehension, the possible risk caused by inserting a light-emitting diode into the intraocular vitreous was much smaller when compared to conventional fiber-based illumination systems. The photochemical and thermal hazards allowed a continuous exposure time to the retina of at least 4.7 h. This first intraocular light source showed that a light-emitting diode can be introduced into the eye. The system can be built as single-use illumination system. This light-source-on-tip light-emitting diode-endo-illumination combines a chandelier wide-angle illumination with an adjustable endo-illuminator.

  16. 21 CFR 310.515 - Patient package inserts for estrogens.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Patient package inserts for estrogens. 310.515 Section 310.515 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE NEW DRUGS Requirements for Specific New Drugs or Devices § 310.515 Patient...

  17. Vaginal flora changes on Pap smears after insertion of levonorgestrel-releasing intrauterine device.

    PubMed

    Donders, Gilbert G G; Berger, Judith; Heuninckx, Hélène; Bellen, Gert; Cornelis, Ann

    2011-04-01

    The levonorgestrel intrauterine system (LNG-IUS) combines a uterine foreign body and the continuous release of low-dose levonorgestrel for contraception. Its influence on the rate of vulvovaginal infections and flora disturbance is insufficiently known, but important for contraceptive advice in women, especially those who develop recurrent vaginosis or Candida vulvovaginitis. Slides of 286 women who had a Pap smear taken before and 1 to 2 years after placement of a LNG-IUS were blindly reviewed for the presence of abnormal vaginal flora (AVF), bacterial vaginosis (BV), aerobic vaginitis (AV) and Candida vaginitis (CV). Prior to insertion, there were no differences in vaginal flora abnormalities between women using different kinds of contraception. LNG-IUS users did not have different rates of AVF, BV, AV or CV, but the general risk to develop any infection was increased. Uterine bleeding after insertion did not seem to predict a different flora type. We found that Pap smears suggested more vaginal infections after 1 year of LNG-IUS use than prior to insertion of the device. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. DEVICE FOR CONTROLLING INSERTION OF ROD

    DOEpatents

    Beaty, B.J.

    1958-10-14

    A device for rapidly inserting a safety rod into a nuclear reactor upon a given signal or in the event of a power failure in order to prevent the possibility of extensive damage caused by a power excursion is described. A piston is slidably mounted within a vertical cylinder with provision for an electromagnetic latch at the top of the cylinder. This assembly, with a safety rod attached to the piston, is mounted over an access port to the core region of the reactor. The piston is normally latched at the top of the cylinder with the safety rod clear of the core area, however, when the latch is released, the piston and rod drop by their own weight to insert the rod. Vents along the side of the cylinder permit the escape of the air entrapped under the piston over the greater part of the distance, however, at the end of the fall the entrapped air is compressed thereby bringing the safety rod gently to rest, thus providing for a rapid automatic insertion of the rod with a minimum of structural shock.

  19. 21 CFR 876.5090 - Suprapubic urological catheter and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... accessories is a flexible tubular device that is inserted through the abdominal wall into the urinary bladder with the aid of a trocar and cannula. The device is used to pass fluids to and from the urinary tract...

  20. The Design and Use of Tungsten Coated TZM Molybdenum Tile Inserts in the DIII-D Tokamak Divertor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murphy, Christopher; Nygren, R. E.; Chrobak, C P.

    Future tokamak devices are envisioned to utilize a high-Z metal divertor with tungsten as theleading candidate. However, tokamak experiments with tungsten divertors have seen significantdetrimental effects on plasma performance. The DIII-D tokamak presently has carbon as theplasma facing surface but to study the effect of tungsten on the plasma and its migration aroundthe vessel, two toroidal rows of carbon tiles in the divertor region were modified with high-Zmetal inserts, composed of a molybdenum alloy (TZM) coated with tungsten. A dedicated twoweek experimental campaign was run with the high-Z metal inserts. One row was coated withtungsten containing naturally occurring levels ofmore » isotopes. The second row was coated withtungsten where the isotope 182W was enhanced from the natural level of 26% up to greater than90%. The different isotopic concentrations enabled the experiment to differentiate between thetwo different sources of metal migration from the divertor. Various coating methods wereexplored for the deposition of the tungsten coating, including chemical vapor deposition,electroplating, vacuum plasma spray, and electron beam physical vapor deposition. The coatingswere tested to see if they were robust enough to act as a divertor target for the experiment. Testsincluded cyclic thermal heating using a high power laser and high-fluence deuterium plasmabombardment. The issues associate with the design of the inserts (tile installation, thermal stress,arcing, leading edges, surface preparation, etc.), are reviewed. The results of the tests used toselect the coating method and preliminary experimental observations are presented.« less

  1. Remote possibly hazardous content container sampling device

    DOEpatents

    Volz, David L.

    1998-01-01

    The present invention relates to an apparatus capable of sampling enclosed containers, where the contents of the container is unknown. The invention includes a compressed air device capable of supplying air pressure, device for controlling the amount of air pressure applied, a pneumatic valve, a sampling device having a hollow, sampling insertion needle suspended therein and device to communicate fluid flow between the container and a containment vessel, pump or direct reading instrument.

  2. Broadband transverse magnetic pass polarizer with low insertion loss based on silicon nitride waveguide

    NASA Astrophysics Data System (ADS)

    Sharma, Tarun Kumar; Ranganath, Praveen; Nambiar, Siddharth; Selvaraja, Shankar Kumar

    2018-03-01

    A horizontally asymmetric transverse magnetic (TM) pass polarizer is presented. The device passes only TM mode and rejects transverse electric (TE) mode. The proposed device has an asymmetricity in the horizontal direction comprising a direction coupler region with a silicon waveguide, silicon nitride waveguide, and an air gap, all residing on silica. Between three equal width Si waveguides, we have one region filled with air and the other with SiN with unequal optimized widths. The device with its optimal dimensions yields an extremely low insertion loss (IL) of 0.16 dB for TM→TM, while TE is rejected by an IL of >48 dB. The proposed polarizer is operated between C&L bands with a high extinction ratio and broadband width of about 110 nm.

  3. Tire deflation device

    DOEpatents

    Barker, Stacey G [Idaho Falls, ID

    2010-01-05

    A tire deflation device includes (1) a component having a plurality of bores, (2) a plurality of spikes removably insertable into the plurality of bores and (3) a keeper within each among the plurality of bores, the keeper being configured to contact a sidewall surface of a spike among the plurality of spikes and to exert force upon the sidewall surface. In an embodiment, the tire deflation device includes (a) a component including a bore in a material, the bore including a receiving region, a sidewall surface and a base surface, (b) a channel extending from the sidewall surface into the material, (c) a keeper having a first section housed within the channel and a second section which extends past the sidewall surface into the receiving region, and (d) a spike removably insertable into the bore.

  4. Source characteristics and design consideration for an iron-free variable-period/polarizing undulator for the UV/VUV range on SPEAR (abstract)

    NASA Astrophysics Data System (ADS)

    Tatchyn, Roman

    1992-01-01

    Insertion devices that are tuned by electrical period variation are particularly suited for the design of flexible polarized-light sources [R. Tatchyn, J. Appl. Phys. 65, 4107 (1989); R. Tatchyn and T. Cremer, IEEE Trans. Mag. 26, 3102 (1990)]. Important advantages vis-a-vis mechanical or hybrid variable field designs include: (1) significantly more rapid modulation of both polarization and energy, (2) an inherently larger set of polarization modulation capabilities and (3) polarization/energy modulation at continuously optimized values of K. In this paper we outline some of the general considerations that enter into the design of hysteresis-free variable-period/polarizing undulator structures and present the parameters of a recently-completed prototype design capable of generating intense levels of UV/VUV photon flux on SPEAR running at 3 GeV.

  5. Status of the SAGA Light Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kaneyasu, T.; Takabayashi, Y.; Iwasaki, Y.

    The SAGA Light Source (SAGA-LS) is a synchrotron radiation facility consisting of a 255 MeV injector linac and a 1.4 GeV storage ring that is 75.6 m in circumference. The SAGA-LS has been stably providing synchrotron radiation to users since it first started user operation in February 2006. Along with the user operation, various machine improvements have been made over the past years, including upgrading the injector linac control system, replacing a septum magnet and constructing a beam diagnostic system. In addition to these improvements, insertion devices have been developed and installed. An APPLE-II type variable polarization undulator was installedmore » in 2008. To address the demand from users for high-flux hard x-rays, a superconducting 4 T class wiggler is being developed. An experimental setup for generating MeV photons by laser Compton scattering is being constructed for beam monitoring and future user experiments.« less

  6. Two year operational experience with the TPS vacuum system

    NASA Astrophysics Data System (ADS)

    Yang, Y. C.; Chan, C. K.; Sheng, I. C.; Huang, I. T.; Y Chung, J.; Liang, C. C.

    2017-07-01

    The Taiwan Photon Source (TPS), a 3-GeV third generation synchrotron light source, was commissioned in 2014 December and is now currently operated in top-up mode at 300mA for users. During the past two years, the machine was completed to meet design goals with among others the installation of superconducting cavities (SRF), the installation of insertion devices (ID) and the correction of vacuum chamber structure downstream from the IDs. The design goal of 500mA beam current was achieved with a total accumulated beam dose of more than 1000Ah, resulting in three orders of magnitude reduction of out-gassing. As the beam current was increased, a few vacuum problems were encountered, including vacuum leaks, unexpected pressure bursts, etc. Vacuum related issues including high pressure events, lessons learned and operational experience will be presented and discussed in this paper.

  7. Stereoscopic augmented reality with pseudo-realistic global illumination effects

    NASA Astrophysics Data System (ADS)

    de Sorbier, Francois; Saito, Hideo

    2014-03-01

    Recently, augmented reality has become very popular and has appeared in our daily life with gaming, guiding systems or mobile phone applications. However, inserting object in such a way their appearance seems natural is still an issue, especially in an unknown environment. This paper presents a framework that demonstrates the capabilities of Kinect for convincing augmented reality in an unknown environment. Rather than pre-computing a reconstruction of the scene like proposed by most of the previous method, we propose a dynamic capture of the scene that allows adapting to live changes of the environment. Our approach, based on the update of an environment map, can also detect the position of the light sources. Combining information from the environment map, the light sources and the camera tracking, we can display virtual objects using stereoscopic devices with global illumination effects such as diffuse and mirror reflections, refractions and shadows in real time.

  8. Design and Manufacturing Criteria for Beam Position Monitor (BPM) of Taiwan Photon Source (TPS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsueh, H. P.; Chang, C. C.; Hsu, S. N.

    2010-06-23

    There are quite some considerations when the button feedthrough is designed and manufactured in a new 3rd generation synchrotron light source like the to-be-constructed TPS. It is the responsibility of the button feedthrough designer to design a feedthrough with the lowest probable HOM problem. It is also required for the designer to analyze the consequences for each possible mechanical error during manufacturing and therefore set standards of tolerance. We have been using MAFIA to optimize the design of feedthrough including flange type on bending chamber section and primary BPM on insertion device section. We also have set some criteria formore » feedthrough manufacturing, inspection, and welding based on hands-on experience on feedthrough electrical properties measuring, sorting, inspection, and laser welding. Here we will present the MAFIA results, electrical measurement results, and laser welding results and analysis. Criteria based on these results will also be presented.« less

  9. Toward operation of series IDs at BL43LXU of SPring-8

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baron, A. Q. R.; Tanaka, T.; Soutome, K.

    2016-07-27

    This paper discusses two issues relating to using 3 small gap insertion devices in series at BL43LXU of SPring-8 to make a uniquely powerful source in the 15-26 keV region of the x-ray spectrum. The issues discussed are (1) damage to the covers of the downstream IDs by radiation from the upstream IDs and (2) proper steering of the electron beam to get the best photon beam properties. After tests in several configurations, including one where an ID was run without an impedance-reducing cover, the damage issue was solved by installing a distributed absorber in the most downstream ID. Themore » steering issues were mostly resolved by the introduction of appropriate corrector magnets and feedback. The paper is written from the viewpoint of an interested beamline scientist impressed with the cooperation of different groups to make a source for new science possible.« less

  10. Design and Manufacturing Criteria for Beam Position Monitor (BPM) of Taiwan Photon Source (TPS)

    NASA Astrophysics Data System (ADS)

    Hsueh, H. P.; Chang, C. C.; Hsu, S. N.; Huang, I. T.; Chen, Y. B.; Kuan, C. K.; Hsiung, G. Y.; Chen, J. R.

    2010-06-01

    There are quite some considerations when the button feedthrough is designed and manufactured in a new 3rd generation synchrotron light source like the to-be-constructed TPS. It is the responsibility of the button feedthrough designer to design a feedthrough with the lowest probable HOM problem. It is also required for the designer to analyze the consequences for each possible mechanical error during manufacturing and therefore set standards of tolerance. We have been using MAFIA to optimize the design of feedthrough including flange type on bending chamber section and primary BPM on insertion device section. We also have set some criteria for feedthrough manufacturing, inspection, and welding based on hands-on experience on feedthrough electrical properties measuring, sorting, inspection, and laser welding. Here we will present the MAFIA results, electrical measurement results, and laser welding results and analysis. Criteria based on these results will also be presented.

  11. Insertion of linear 8.4 μm diameter 16 channel carbon fiber electrode arrays for single unit recordings

    PubMed Central

    Patel, Paras R.; Na, Kyounghwan; Zhang, Huanan; Kozai, Takashi D. Y.; Kotov, Nicholas A.; Yoon, Euisik; Chestek, Cynthia A.

    2016-01-01

    Objective Single carbon fiber electrodes (d=8.4 μm) insulated with parylene-c and functionalized with PEDOT:pTS have been shown to record single unit activity but manual implantation of these devices with forceps can be difficult. Without an improvement in the insertion method any increase in the channel count by fabricating carbon fiber arrays would be impractical. In this study, we utilize a water soluble coating and structural backbones that allow us to create, implant, and record from fully functionalized arrays of carbon fibers with ~150 μm pitch. Approach Two approaches were tested for the insertion of carbon fiber arrays. The first method used a PEG coating that temporarily stiffened the fibers while leaving a small portion at the tip exposed. The small exposed portion (500 μm – 1 mm) readily penetrated the brain allowing for an insertion that did not require the handling of each fiber by forceps. The second method involved the fabrication of silicon support structures with individual shanks spaced 150 μm apart. Each shank consisted of a small groove that held an individual carbon fiber. Main results Our results showed that the PEG coating allowed for the chronic implantation of carbon fiber arrays in 5 rats with unit activity detected at 31 days post-implant. The silicon support structures recorded single unit activity in 3 acute rat surgeries. In one of those surgeries a stacked device with 3 layers of silicon support structures and carbon fibers was built and shown to readily insert into the brain with unit activity on select sites. Significance From these studies we have found that carbon fibers spaced at ~150 μm readily insert into the brain. This greatly increases the recording density of chronic neural probes and paves the way for even higher density devices that have a minimal scarring response. PMID:26035638

  12. Photon beam position monitor

    DOEpatents

    Kuzay, T.M.; Shu, D.

    1995-02-07

    A photon beam position monitor is disclosed for use in the front end of a beamline of a high heat flux and high energy photon source such as a synchrotron radiation storage ring detects and measures the position and, when a pair of such monitors are used in tandem, the slope of a photon beam emanating from an insertion device such as a wiggler or an undulator inserted in the straight sections of the ring. The photon beam position monitor includes a plurality of spaced blades for precisely locating the photon beam, with each blade comprised of chemical vapor deposition (CVD) diamond with an outer metal coating of a photon sensitive metal such as tungsten, molybdenum, etc., which combination emits electrons when a high energy photon beam is incident upon the blade. Two such monitors are contemplated for use in the front end of the beamline, with the two monitors having vertically and horizontally offset detector blades to avoid blade ''shadowing''. Provision is made for aligning the detector blades with the photon beam and limiting detector blade temperature during operation. 18 figs.

  13. Biliary and pancreatic stenting: Devices and insertion techniques in therapeutic endoscopic retrograde cholangiopancreatography and endoscopic ultrasonography

    PubMed Central

    Mangiavillano, Benedetto; Pagano, Nico; Baron, Todd H; Arena, Monica; Iabichino, Giuseppe; Consolo, Pierluigi; Opocher, Enrico; Luigiano, Carmelo

    2016-01-01

    Stents are tubular devices made of plastic or metal. Endoscopic stenting is the most common treatment for obstruction of the common bile duct or of the main pancreatic duct, but also employed for the treatment of bilio-pancreatic leakages, for preventing post- endoscopic retrograde cholangiopancreatography pancreatitis and to drain the gallbladder and pancreatic fluid collections. Recent progresses in techniques of stent insertion and metal stent design are represented by new, fully-covered lumen apposing metal stents. These stents are specifically designed for transmural drainage, with a saddle-shape design and bilateral flanges, to provide lumen-to-lumen anchoring, reducing the risk of migration and leakage. This review is an update of the technique of stent insertion and metal stent deployment, of the most recent data available on stent types and characteristics and the new applications for biliopancreatic stents. PMID:26862364

  14. Design and evaluation of a computed tomography (CT)-compatible needle insertion device using an electromagnetic tracking system and CT images.

    PubMed

    Shahriari, Navid; Hekman, Edsko; Oudkerk, Matthijs; Misra, Sarthak

    2015-11-01

    Percutaneous needle insertion procedures are commonly used for diagnostic and therapeutic purposes. Although current technology allows accurate localization of lesions, they cannot yet be precisely targeted. Lung cancer is the most common cause of cancer-related death, and early detection reduces the mortality rate. Therefore, suspicious lesions are tested for diagnosis by performing needle biopsy. In this paper, we have presented a novel computed tomography (CT)-compatible needle insertion device (NID). The NID is used to steer a flexible needle (φ0.55 mm) with a bevel at the tip in biological tissue. CT images and an electromagnetic (EM) tracking system are used in two separate scenarios to track the needle tip in three-dimensional space during the procedure. Our system uses a control algorithm to steer the needle through a combination of insertion and minimal number of rotations. Noise analysis of CT images has demonstrated the compatibility of the device. The results for three experimental cases (case 1: open-loop control, case 2: closed-loop control using EM tracking system and case 3: closed-loop control using CT images) are presented. Each experimental case is performed five times, and average targeting errors are 2.86 ± 1.14, 1.11 ± 0.14 and 1.94 ± 0.63 mm for case 1, case 2 and case 3, respectively. The achieved results show that our device is CT-compatible and it is able to steer a bevel-tipped needle toward a target. We are able to use intermittent CT images and EM tracking data to control the needle path in a closed-loop manner. These results are promising and suggest that it is possible to accurately target the lesions in real clinical procedures in the future.

  15. Non-hydrolytic metal oxide films for perovskite halide overcoating and stabilization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martinson, Alex B.; Kim, In Soo

    A method of protecting a perovskite halide film from moisture and temperature includes positioning the perovskite halide film in a chamber. The chamber is maintained at a temperature of less than 200 degrees Celsius. An organo-metal compound is inserted into the chamber. A non-hydrolytic oxygen source is subsequently inserted into the chamber. The inserting of the organo-metal compound and subsequent inserting of the non-hydrolytic oxygen source into the chamber is repeated for a predetermined number of cycles. The non-hydrolytic oxygen source and the organo-metal compound interact in the chamber to deposit a non-hydrolytic metal oxide film on perovskite halide film.more » The non-hydrolytic metal oxide film protects the perovskite halide film from relative humidity of greater than 35% and a temperature of greater than 150 degrees Celsius, respectively.« less

  16. Effect of footwear and orthotic devices on stress reduction and soft tissue strain of the neuropathic foot.

    PubMed

    Lott, Donovan J; Hastings, Mary K; Commean, Paul K; Smith, Kirk E; Mueller, Michael J

    2007-03-01

    Ground reaction forces from walking result in stress (pressure) and soft tissue strain at the plantar aspect of the foot. Excessive plantar pressure and tissue strain on the insensate foot may lead to ulceration. Our study investigated the effect of therapeutic footwear and custom-made orthotic inserts on pressure and tissue strain along the second ray of the plantar foot, and how these two variables are associated. Twenty subjects (mean age 57.3 [SD 9.3] years, 12 male, 8 female, body mass index 32.5 [SD 7.4] kg/m2) with diabetes mellitus, peripheral neuropathy, and a history of a plantar ulcer participated. Plantar pressure data were recorded during computed tomography scans for four conditions (barefoot, shoe, shoe+total contact insert, and shoe+total contact insert+metatarsal pad). For each condition tested, tissue strain and plantar pressure were determined at the second metatarsal head and at 15 other points along the second ray. Differences were noted between the 4 conditions for pressure (P<0.004) and soft tissue strain (P<0.042) at the second metatarsal head. Correlation coefficients demonstrated an association between pressure and strain (Barefoot r=0.81, Shoe r=0.75, Shoe+total contact insert r=0.73, and Shoe+total contact insert+metatarsal pad r=0.44). Footwear and orthotic devices tested in this study decreased pressure and soft tissue strain at the second ray of the foot, and these two variables were strongly related. A better understanding of the role tissue strain plays in distributing plantar forces may lead to improvements in the design of orthotic devices.

  17. Effect of Footwear and Orthotic Devices on Stress Reduction and Soft Tissue Strain of the Neuropathic Foot

    PubMed Central

    Lott, Donovan J.; Hastings, Mary K.; Commean, Paul K.; Smith, Kirk E.; Mueller, Michael J.

    2007-01-01

    Background Ground reaction forces from walking result in stress (pressure) and soft tissue strain at the plantar aspect of the foot. Excessive plantar pressure and tissue strain on the insensate foot may lead to ulceration. Our study investigated the effect of therapeutic footwear and custom-made orthotic inserts on pressure and tissue strain along the second ray of the plantar foot, and how these two variables are associated. Methods Twenty subjects (mean age 57.3 [SD 9.3], 12 male, 8 female, body mass index 32.5 [SD 7.4]) with diabetes mellitus, peripheral neuropathy, and a history of a plantar ulcer participated. Plantar pressure data were recorded during computed tomography scans for four conditions (barefoot, shoe, shoe+total contact insert, and shoe+total contact insert+metatarsal pad). For each condition tested, tissue strain and plantar pressure were determined at the second metatarsal head and at 15 other points along the second ray. Findings Differences were noted between the 4 conditions for pressure (p < 0.004) and soft tissue strain (p < 0.042) at the second metatarsal head. Correlation coefficients demonstrated an association between pressure and strain (Barefoot r = 0.81, Shoe r = 0.75, Shoe+total contact insert r = 0.73, and Shoe+total contact insert+metatarsal pad r = 0.44). Intepretation Footwear and orthotic devices tested in this study decreased pressure and soft tissue strain at the second ray of the foot, and these two variables were strongly related. A better understanding of the role tissue strain plays in distributing plantar forces may lead to improvements in the design of orthotic devices. PMID:17182156

  18. 76 FR 51876 - Medical Devices; Ophthalmic Devices; Classification of the Eyelid Thermal Pulsation System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-19

    ... meibomian gland dysfunction (MGD), also known as evaporative dry eye or lipid deficiency dry eye. The system... evaporative dry eye or lipid deficiency dry eye. The system consists of a component that is inserted around...

  19. 21 CFR 876.1400 - Stomach pH electrode.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... ion concentration). The pH electrode is at the end of a flexible lead which may be inserted into the... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Stomach pH electrode. 876.1400 Section 876.1400...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1400 Stomach pH electrode. (a...

  20. 21 CFR 876.1400 - Stomach pH electrode.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... ion concentration). The pH electrode is at the end of a flexible lead which may be inserted into the... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Stomach pH electrode. 876.1400 Section 876.1400...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1400 Stomach pH electrode. (a...

  1. 21 CFR 876.1400 - Stomach pH electrode.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... ion concentration). The pH electrode is at the end of a flexible lead which may be inserted into the... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Stomach pH electrode. 876.1400 Section 876.1400...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1400 Stomach pH electrode. (a...

  2. Comparison of custom and prefabricated orthoses in the initial treatment of proximal plantar fasciitis.

    PubMed

    Pfeffer, G; Bacchetti, P; Deland, J; Lewis, A; Anderson, R; Davis, W; Alvarez, R; Brodsky, J; Cooper, P; Frey, C; Herrick, R; Myerson, M; Sammarco, J; Janecki, C; Ross, S; Bowman, M; Smith, R

    1999-04-01

    Fifteen centers for orthopaedic treatment of the foot and ankle participated in a prospective randomized trial to compare several nonoperative treatments for proximal plantar fasciitis (heel pain syndrome). Included were 236 patients (160 women and 76 men) who were 16 years of age or older. Most reported duration of symptoms of 6 months or less. Patients with systemic disease, significant musculoskeletal complaints, sciatica, or local nerve entrapment were excluded. We randomized patients prospectively into five different treatment groups. All groups performed Achilles tendon- and plantar fascia-stretching in a similar manner. One group was treated with stretching only. The other four groups stretched and used one of four different shoe inserts, including a silicone heel pad, a felt pad, a rubber heel cup, or a custom-made polypropylene orthotic device. Patients were reevaluated after 8 weeks of treatment. The percentages improved in each group were: (1) silicone insert, 95%; (2) rubber insert, 88%; (3) felt insert, 81%; (4)stretching only, 72%; and (5) custom orthosis, 68%. Combining all the patients who used a prefabricated insert, we found that their improvement rates were higher than those assigned to stretching only (P = 0.022) and those who stretched and used a custom orthosis (P = 0.0074). We conclude that, when used in conjunction with a stretching program, a prefabricated shoe insert is more likely to produce improvement in symptoms as part of the initial treatment of proximal plantar fasciitis than a custom polypropylene orthotic device.

  3. Doppler color flow analysis of the uterine arteries before and after intrauterine device insertion: a prospective study.

    PubMed

    de Souza, Marco Aurélio Martins; Geber, Selmo

    2006-02-01

    An intrauterine device (IUD) is one of the most frequently used methods of birth control around the world. Although a relationship between its use and menstrual disorders has been well documented, only a few studies have tried to show whether there are any vascular modifications. The aim of our study was to evaluate the influence of an IUD on uterine artery blood flow using Doppler assessment. A total of 100 patients selected for IUD use were prospectively evaluated with Doppler analysis before and 30 days after insertion. The resistive index (RI) and pulsatility index (PI) were used to evaluate uterine artery vascular resistance. Patients were allocated in 2 groups according to whether they were (group 2) or were not (group 1) lactating. The PI and RI of the patients in groups 1 and 2 before and after IUD insertion were not statistically significantly different (P = .298 and .23). When we compared uterine artery blood flow indices before and after IUD insertion for groups 1 and 2 separately, we observed in group 1 that the mean +/- SD PI values were 2.45 +/- 0.62 and 2.55 +/- 0.55 (P = .38) and the RI values were 0.87 +/- 0.08 and 0.87 +/- 0.06 (P = .88) before and after IUD insertion, respectively. In group 2, the PI values were 2.31 +/- 0.55 and 2.37 +/- 0.69 (P = .68) and the RI values were 0.85 +/- 0.07 and 0.86 +/- 0.07 (P = .44) before and after IUD insertion. Finally, we used the mean blood flow indices of the uterine arteries of all patients to compare the effect of IUD insertion. Results were also not statistically significant when we compared PI and RI before and after IUD insertion. The presence of an IUD does not interfere with the vascular resistance of the uterine arteries that can be shown by Doppler flow assessments 1 month after insertion.

  4. Effect of inserting a hole injection layer in organic light-emitting diodes: A numerical approach

    NASA Astrophysics Data System (ADS)

    Lee, Hyeongi; Hwang, Youngwook; Won, Taeyoung

    2015-01-01

    For investigating the effect of inserting a hole injection layer (HIL), we carried out a computational study concerning organic light-emitting diodes (OLEDs) that had a thin CuPc layer as the hole injection layer. We used S-TAD (2, 2', 7, 7'-tetrakis-(N, Ndiphenylamino)-9, 9-spirobifluoren) for the hole transfer layer, S-DPVBi (4, 4'-bis (2, 2'-diphenylvinyl)-1, 1'-spirobiphenyl) for the emission layer and Alq3 (Tris (8-hyroxyquinolinato) aluminium) for the electron transfer layer. This tri-layer device was compared with four-layer devices. To this tri-layer device, we added a thin CuPc layer, which had a 5.3 eV highest occupied molecular orbital (HOMO) level and a 3.8 eV lowest unoccupied molecular orbital (LUMO) level, as a hole injection layer, and we chose this device for Device A. Also, we varied the LUMO level or the HOMO level of the thin CuPc layer. These two devices were identified as Device C and Device D, respectively. In this paper, we simulated the carrier injection, transport and recombination in these four devices. Thereby, we showed the effect of the HIL, and we demonstrated that the characteristics of these devices were improved by adding a thin layer of CuPc between the anode and the HTL.

  5. "Space slitter" for film or tape

    NASA Technical Reports Server (NTRS)

    Johnson, W. H.

    1978-01-01

    Device cuts film or tape into strips by guiding film in channel under cutting blades. Device is operated by lifting pressure bar to insert blades into film. Film is then pulled through blades. Cutter has potential uses in advertising, commercial art, and publishing fields.

  6. Electrochromic devices based on lithium insertion

    DOEpatents

    Richardson, Thomas J.

    2006-05-09

    Electrochromic devices having as an active electrode materials comprising Sb, Bi, Si, Ge, Sn, Te, N, P, As, Ga, In, Al, C, Pb, I and chalcogenides are disclosed. The addition of other metals, i.e. Ag and Cu to the active electrode further enhances performance.

  7. Catalytic action of β source on x-ray emission from plasma focus

    NASA Astrophysics Data System (ADS)

    Ahmad, S.; Sadiq, Mehboob; Hussain, S.; Shafiq, M.; Zakaullah, M.; Waheed, A.

    2006-01-01

    The influence of preionization around the insulator sleeve by a mesh-type β source (Ni6328) for the x-ray emission from a (2.3-3.9 kJ) plasma focus device is investigated. Quantrad Si p-i-n diodes along with suitable filters are employed as time-resolved x-ray detectors and a multipinhole camera with absorption filters is used for time-integrated analysis. X-ray emission in 4π geometry is measured as a function of argon and hydrogen gas filling pressures with and without β source at different charging voltages. It is found that the pressure range for the x-ray emission is broadened, x-ray emission is enhanced, and shot to shot reproducibility is improved with the β source. With argon, the CuKα emission is estimated to be 27.14 J with an efficiency of 0.7% for β source and 21.5 J with an efficiency of 0.55% without β source. The maximum x-ray yield in 4π geometry is found to be about 68.90 J with an efficiency of 1.8% for β source and 54.58 J with an efficiency of 1.4% without β source. With hydrogen, CuKα emission is 11.82 J with an efficiency of 0.32% for β source and 10.07 J with an efficiency of 0.27% without β source. The maximum x-ray yield in 4π geometry is found to be 30.20 J with an efficiency of 0.77% for β source and 25.58 J with an efficiency of 0.6% without β source. The x-ray emission with Pb insert at the anode tip without β source is also investigated and found to be reproducible and significantly high. The maximum x-ray yield is estimated to be 46.6 J in 4π geometry with an efficiency of 1.4% at 23 kV charging voltage. However, degradation of x-ray yield is observed when charging voltage exceeds 23 kV for Pb insert. From pinhole images it is observed that the x-ray emission due to the bombardment of electrons at the anode tip is dominant in both with and without β source.

  8. Real-Time Deposition Monitor for Ultrathin Conductive Films

    NASA Technical Reports Server (NTRS)

    Hines, Jacqueline

    2011-01-01

    A device has been developed that can be used for the real-time monitoring of ultrathin (2 or more) conductive films. The device responds in less than two microseconds, and can be used to monitor film depositions up to about 60 thick. Actual thickness monitoring capability will vary based on properties of the film being deposited. This is a single-use device, which, due to the very low device cost, can be disposable. Conventional quartz/crystal microbalance devices have proven inadequate to monitor the thickness of Pd films during deposition of ultrathin films for hydrogen sensor devices. When the deposited film is less than 100 , the QCM measurements are inadequate to allow monitoring of the ultrathin films being developed. Thus, an improved, high-sensitivity, real-time deposition monitor was needed to continue Pd film deposition development. The new deposition monitor utilizes a surface acoustic wave (SAW) device in a differential delay-line configuration to produce both a reference response and a response for the portion of the device on which the film is being deposited. Both responses are monitored simultaneously during deposition. The reference response remains unchanged, while the attenuation of the sensing path (where the film is being deposited) varies as the film thickness increases. This device utilizes the fact that on high-coupling piezoelectric substrates, the attenuation of an SAW undergoes a transition from low to very high, and back to low as the conductivity of a film on the device surface goes from nonconductive to highly conductive. Thus, the sensing path response starts with a low insertion loss, and as a conductive film is deposited, the film conductivity increases, causing the device insertion loss to increase dramatically (by up to 80 dB or more), and then with continued film thickness increases (and the corresponding conductivity increases), the device insertion loss goes back down to the low level at which it started. This provides a continuous, real-time monitoring of film deposition. For use with different films, the device would need to be calibrated to provide an understanding of how film thickness is related to film conductivity, as the device is responding primarily to conductivity effects (and not to mass loading effects) in this ultrathin film regime.

  9. A linear 180 nm SOI CMOS antenna switch module using integrated passive device filters for cellular applications

    NASA Astrophysics Data System (ADS)

    Jie, Cui; Lei, Chen; Peng, Zhao; Xu, Niu; Yi, Liu

    2014-06-01

    A broadband monolithic linear single pole, eight throw (SP8T) switch has been fabricated in 180 nm thin film silicon-on-insulator (SOI) CMOS technology with a quad-band GSM harmonic filter in integrated passive devices (IPD) technology, which is developed for cellular applications. The antenna switch module (ASM) features 1.2 dB insertion loss with filter on 2G bands and 0.4 dB insertion loss in 3G bands, less than -45 dB isolation and maximum -103 dB intermodulation distortion for mobile front ends by applying distributed architecture and adaptive supply voltage generator.

  10. Coil spring venting arrangement

    DOEpatents

    McCugh, R.M.

    1975-10-21

    A simple venting device for trapped gas pockets in hydraulic systems is inserted through a small access passages, operated remotely, and removed completely. The device comprises a small diameter, closely wound coil spring which is pushed through a guide temporarily inserted in the access passage. The guide has a central passageway which directs the coil spring radially upward into the pocket, so that, with the guide properly positioned for depth and properly oriented, the coil spring can be pushed up into the top of the pocket to vent it. By positioning a seal around the free end of the guide, the spring and guide are removed and the passage is sealed.

  11. Group B streptococci in women fitted with intrauterine devices.

    PubMed Central

    Mitchell, R G; Guillebaud, J; Day, D G

    1977-01-01

    A survey was made of group B streptococcal carriage at various sites in 100 women attending a clinic for the insertion of an intrauterine contraceptive device (IUD). Twenty-three women carried streptococci at one or more sites at the preinsertion visit, the vaginal carriage rate being 16%. Six months after insertion changes in carrier status were noted and there was evidence of a change of strain in four patients. Twenty-nine women were carriers at one or more sites at some stage of the study. There was no evidence that symptoms attributable to infection in patients fitted with an IUD were caused by group B streptococci. PMID:338639

  12. [Intrauterine device: about a rare complication and literature review].

    PubMed

    Kallat, Adil; Ibrahimi, Ahmed; Fahsi, Otheman; El Sayegh, Hachem; Iken, Ali; Benslimane, Lounis; Nouini, Yassine

    2017-01-01

    The intrauterine device (IUD) is the most common contraceptive method used in the world. Transuterine migration is a rare complication, accounting for 1/350 - 1/10000 insertions in the literature. We report the case of a 40-year old patient, who had had an IUD insertion 12-year before, presenting with pelvic and right lower back pain associated with intermittent hematuria and burning during urination. Radiological assessment showed calcific deposits on intra bladder IUD. The patient underwent cystostomy, without any difficulty, allowing stone and IUD extraction. A urinary catheter was left in place for 5 days and then withdrawn. The postoperative course was uneventful.

  13. Limited Uptake of Planned Intrauterine Devices During the Postpartum Period.

    PubMed

    Salcedo, Jennifer; Moniaga, Natalie; Harken, Tabetha

    2015-08-01

    The primary objective of this study was to determine the percentage of women with a documented plan for postpartum intrauterine device (IUD) insertion who had a device inserted within 8 weeks of delivery. The secondary objective was to determine factors associated with successful initiation of postpartum IUDs as planned. We conducted a retrospective chart review of women who had at least one prenatal visit and delivered a viable pregnancy at our academic medical center. Methods of planned and established postpartum contraceptive methods were recorded, as well as demographic information and documented reasons for failure to initiate planned intrauterine contraception. A total of 110 women planned postpartum IUD placement. Of these women, 84 (76%) presented for at least one postpartum appointment. Only 22.6% (95% confidence interval 13.7-31.5) of those presenting for postpartum follow-up underwent IUD placement within 8 weeks of delivery. Women planning postpartum IUD insertion were just as likely as women with no planned postpartum contraceptive method to fail to establish contraception within 8 weeks (P = 0.55). Failure to establish planned postpartum intrauterine contraception occurs frequently, even in a setting with a high rate of postpartum follow-up.

  14. Malaria rapid diagnostic kits: quality of packaging, design and labelling of boxes and components and readability and accuracy of information inserts

    PubMed Central

    2011-01-01

    Background The present study assessed malaria RDT kits for adequate and correct packaging, design and labelling of boxes and components. Information inserts were studied for readability and accuracy of information. Methods Criteria for packaging, design, labelling and information were compiled from Directive 98/79 of the European Community (EC), relevant World Health Organization (WHO) documents and studies on end-users' performance of RDTs. Typography and readability level (Flesch-Kincaid grade level) were assessed. Results Forty-two RDT kits from 22 manufacturers were assessed, 35 of which had evidence of good manufacturing practice according to available information (i.e. CE-label affixed or inclusion in the WHO list of ISO13485:2003 certified manufacturers). Shortcomings in devices were (i) insufficient place for writing sample identification (n = 40) and (ii) ambiguous labelling of the reading window (n = 6). Buffer vial labels were lacking essential information (n = 24) or were of poor quality (n = 16). Information inserts had elevated readability levels (median Flesch Kincaid grade 8.9, range 7.1 - 12.9) and user-unfriendly typography (median font size 8, range 5 - 10). Inadequacies included (i) no referral to biosafety (n = 18), (ii) critical differences between depicted and real devices (n = 8), (iii) figures with unrealistic colours (n = 4), (iv) incomplete information about RDT line interpretations (n = 31) and no data on test characteristics (n = 8). Other problems included (i) kit names that referred to Plasmodium vivax although targeting a pan-species Plasmodium antigen (n = 4), (ii) not stating the identity of the pan-species antigen (n = 2) and (iii) slight but numerous differences in names displayed on boxes, device packages and information inserts. Three CE labelled RDT kits produced outside the EC had no authorized representative affixed and the shape and relative dimensions of the CE symbol affixed did not comply with the Directive 98/79/EC. Overall, RDTs with evidence of GMP scored better compared to those without but inadequacies were observed in both groups. Conclusion Overall, malaria RDTs showed shortcomings in quality of construction, design and labelling of boxes, device packages, devices and buffers. Information inserts were difficult to read and lacked relevant information. PMID:21314992

  15. Reticular telangiectatic erythema: case report and literature review.

    PubMed

    Beutler, Bryce D; Cohen, Philip R

    2015-01-01

    Reticular telangiectatic erythema is a benign cutaneous reaction that may occur in patients who have received a subcutaneous implantable cardioverter-defibrillator. Reticular telangiectatic erythema is characterized by asymptomatic telangiectasias, blanchable erythematous patches, or both overlying and/or adjacent to the subcutaneous implantable cardioverter-defibrillator. We describe a man who developed reticular telangiectatic erythema after receiving a subcutaneous implantable cardioverter-defibrillator and review the salient features of this condition. We also summarize the conditions that can mimic reticular telangiectatic erythema. The features of a man with reticular telangiectatic erythema are presented and the literature on reticular telangiectatic erythema is reviewed. Our patient developed reticular telangiectatic erythema within one month of subcutaneous implantable cardioverter-defibrillator insertion. The subcutaneous manifestations were asymptomatic. The patient concurred to have periodic clinical follow up and his condition will be monitored for any changes. Reticular telangiectatic erythema is a benign condition characterized by the development of erythema, telangiectasia, or both following insertion of a subcutaneous implantable cardioverter-defibrillator. Other subcutaneous implantable cardioverter-defibrillator-related side effects, such as pressure dermatitis and contact dermatitis, can mimic the condition. Reticular telangiectatic erythema can also be observed following insertion of other devices or, rarely, in the absence of inserted devices. Local microcirculatory changes and subcutaneous implantable cardioverter-defibrillator-related obstruction of blood flow have been suggested as possible mechanisms of pathogenesis. The diagnosis can usually be established by clinical presentation. Therefore, patch testing can usually be omitted. Reticular telangiectatic erythema is typically asymptomatic and thus removal of the device is not required.

  16. Method for improving the durability of ion insertion materials

    DOEpatents

    Lee, Se-Hee; Tracy, C. Edwin; Cheong, Hyeonsik M.

    2002-01-01

    The invention provides a method of protecting an ion insertion material from the degradative effects of a liquid or gel-type electrolyte material by disposing a protective, solid ion conducting, electrically insulating, layer between the ion insertion layer and the liquid or gel-type electrolyte material. The invention further provides liquid or gel-type electrochemical cells having improved durability having a pair of electrodes, a pair of ion insertion layers sandwiched between the pair of electrodes, a pair of solid ion conducting layers sandwiched between the ion insertion layers, and a liquid or gel-type electrolyte material disposed between the solid ion conducting layers, where the solid ion conducting layer minimizes or prevents degradation of the faces of the ion insertion materials facing the liquid or gel-type electrolyte material. Electrochemical cells of this invention having increased durability include secondary lithium batteries and electrochromic devices.

  17. A backing device based on an embedded stiffener and retractable insertion tool for thin-film cochlear arrays

    NASA Astrophysics Data System (ADS)

    Tewari, Radheshyam

    Intracochlear trauma from surgical insertion of bulky electrode arrays and inadequate pitch perception are areas of concern with current hand-assembled commercial cochlear implants. Parylene thin-film arrays with higher electrode densities and lower profiles are a potential solution, but lack rigidity and hence depend on manually fabricated permanently attached polyethylene terephthalate (PET) tubing based bulky backing devices. As a solution, we investigated a new backing device with two sub-systems. The first sub-system is a thin poly(lactic acid) (PLA) stiffener that will be embedded in the parylene array. The second sub-system is an attaching and detaching mechanism, utilizing a poly(N-vinylpyrrolidone)-block-poly(d,l-lactide) (PVP-b-PDLLA) copolymer-based biodegradable and water soluble adhesive, that will help to retract the PET insertion tool after implantation. As a proof-of-concept of sub-system one, a microfabrication process for patterning PLA stiffeners embedded in parylene has been developed. Conventional hot-embossing, mechanical micromachining, and standard cleanroom processes were integrated for patterning fully released and discrete stiffeners coated with parylene. The released embedded stiffeners were thermoformed to demonstrate that imparting perimodiolar shapes to stiffener-embedded arrays will be possible. The developed process when integrated with the array fabrication process will allow fabrication of stiffener-embedded arrays in a single process. As a proof-of-concept of sub-system two, the feasibility of the attaching and detaching mechanism was demonstrated by adhering 1x and 1.5x scale PET tube-based insertion tools and PLA stiffeners embedded in parylene using the copolymer adhesive. The attached devices survived qualitative adhesion tests, thermoforming, and flexing. The viability of the detaching mechanism was tested by aging the assemblies in-vitro in phosphate buffer solution. The average detachment times, 2.6 minutes and 10 minutes for 1x and 1.5x scale devices respectively, were found to be clinically relevant with respect to the reported array insertion times during surgical implantation. Eventually, the stiffener-embedded arrays would not need to be permanently attached to current insertion tools which are left behind after implantation and congest the cochlear scala tympani chamber. Finally, a simulation-based approach for accelerated failure analysis of PLA stiffeners and characterization of PVP-b-PDLLA copolymer adhesive has been explored. The residual functional life of embedded PLA stiffeners exposed to body-fluid and thereby subjected to degradation and erosion has been estimated by simulating PLA stiffeners with different parylene coating failure types and different PLA types for a given parylene coating failure type. For characterizing the PVP-b-PDLLA copolymer adhesive, several formulations of the copolymer adhesive were simulated and compared based on the insertion tool detachment times that were predicted from the dissolution, degradation, and erosion behavior of the simulated adhesive formulations. Results indicate that the simulation-based approaches could be used to reduce the total number of time consuming and expensive in-vitro tests that must be conducted.

  18. LOADING DEVICE

    DOEpatents

    Ohlinger, L.A.

    1958-10-01

    A device is presented for loading or charging bodies of fissionable material into a reactor. This device consists of a car, mounted on tracks, into which the fissionable materials may be placed at a remote area, transported to the reactor, and inserted without danger to the operating personnel. The car has mounted on it a heavily shielded magazine for holding a number of the radioactive bodies. The magazine is of a U-shaped configuration and is inclined to the horizontal plane, with a cap covering the elevated open end, and a remotely operated plunger at the lower, closed end. After the fissionable bodies are loaded in the magazine and transported to the reactor, the plunger inserts the body at the lower end of the magazine into the reactor, then is withdrawn, thereby allowing gravity to roll the remaining bodies into position for successive loading in a similar manner.

  19. Clinical outcomes of VNS therapy with AspireSR® (including cardiac-based seizure detection) at a large complex epilepsy and surgery centre.

    PubMed

    Hamilton, Preci; Soryal, Imad; Dhahri, Prince; Wimalachandra, Welege; Leat, Anna; Hughes, Denise; Toghill, Nicole; Hodson, James; Sawlani, Vijay; Hayton, Tom; Samarasekera, Shanika; Bagary, Manny; McCorry, Dougall; Chelvarajah, Ramesh

    2018-05-01

    To compare the efficacy of AspireSR ® to preceding VNS battery models for battery replacements, and to determine the efficacy of the AspireSR ® for new implants. Data were collected retrospectively from patients with epilepsy who had VNS AspireSR ® implanted over a three-year period between June 2014 and June 2017 by a single surgeon. Cases were divided into two cohorts, those in whom the VNS was a new insertion, and those in whom the VNS battery was changed from a previous model to AspireSR ® . Within each group, the seizure burden was compared between the periods before and after insertion of AspireSR ® . Fifty-one patients with a newly inserted AspireSR ® VNS model had a significant reduction in seizure frequency (p < 0.001), with 59% (n = 30) reporting ≥50% reduction. Of the 62 patients who had an existing VNS, 53% (n = 33) reported ≥50% reduction in seizure burden when the original VNS was inserted. After the battery was changed to the AspireSR ® , 71% (n = 44) reported a further reduction of ≥50% in their seizure burden. The size of this reduction was at least as large as that resulting from the insertion of their existing VNS in 98% (61/62) of patients. The results suggest that approximately 70% of patients with existing VNS insertions could have significant additional benefit from cardiac based seizure detection and closed loop stimulation from the AspireSR ® device. For new insertions, the AspireSR ® device has efficacy in 59% of patients. The 'rule of thirds' used in counseling patients may need to be modified accordingly. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  20. Risk-based screening for Chlamydia trachomatis and Neisseria gonorrhoeae prior to intrauterine device insertion.

    PubMed

    Grentzer, Jaclyn M; Peipert, Jeffrey F; Zhao, Qiuhong; McNicholas, Colleen; Secura, Gina M; Madden, Tessa

    2015-10-01

    The objective was to compare three strategies for Chlamydia trachomatis and Neisseria gonorrhoeae screening prior to intrauterine device (IUD) insertion. This was a secondary analysis of the Contraceptive CHOICE Project. We measured the prevalence of C. trachomatis and/or N. gonorrhoeae at the time of IUD insertion. We then compared sensitivity, specificity, negative and positive predictive values, and likelihood ratios for three screening strategies for C. trachomatis and N. gonorrhoeae prior to IUD insertion: (a) "age-based" — age ≤25 years alone; (b) "age/partner-based" — age ≤25 and/or multiple sexual partners; and (c) "risk-based" — age ≤25, multiple sexual partners, inconsistent condom use and/or history of prior sexually transmitted infection (STI). Among 5087 IUD users, 140 (2.8%) tested positive for C. trachomatis, 16 (0.3%) tested positive for N. gonorrhoeae, and 6 (0.1%) were positive for both at the time of IUD insertion. The "risk-based" screening strategy had the highest sensitivity (99.3%) compared to "age-based" and "age/partner-based" screening (80.7% and 84.7%, respectively.) Only one (0.7%) woman with a chlamydia or gonorrhea infection would not have been screened using "risk-based" screening. A risk-based strategy to screen for C. trachomatis and N. gonorrhoeae prior to IUD insertion has higher sensitivity than screening based on age alone or age and multiple sexual partners. Using a risk-based screening strategy (age≤25, multiple sexual partners, inconsistent condom use and/or history of an STI) to determine who should be screened for C. trachomatis and N. gonorrhoeae prior to IUD insertion will miss very few cases of infection and obviates the need for universal screening. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. A new method and device of aligning patient setup lasers in radiation therapy.

    PubMed

    Hwang, Ui-Jung; Jo, Kwanghyun; Lim, Young Kyung; Kwak, Jung Won; Choi, Sang Hyuon; Jeong, Chiyoung; Kim, Mi Young; Jeong, Jong Hwi; Shin, Dongho; Lee, Se Byeong; Park, Jeong-Hoon; Park, Sung Yong; Kim, Siyong

    2016-01-08

    The aim of this study is to develop a new method to align the patient setup lasers in a radiation therapy treatment room and examine its validity and efficiency. The new laser alignment method is realized by a device composed of both a metallic base plate and a few acrylic transparent plates. Except one, every plate has either a crosshair line (CHL) or a single vertical line that is used for alignment. Two holders for radiochromic film insertion are prepared in the device to find a radiation isocenter. The right laser positions can be found optically by matching the shadows of all the CHLs in the gantry head and the device. The reproducibility, accuracy, and efficiency of laser alignment and the dependency on the position error of the light source were evaluated by comparing the means and the standard deviations of the measured laser positions. After the optical alignment of the lasers, the radiation isocenter was found by the gantry and collimator star shots, and then the lasers were translated parallel to the isocenter. In the laser position reproducibility test, the mean and standard deviation on the wall of treatment room were 32.3 ± 0.93 mm for the new method whereas they were 33.4 ± 1.49 mm for the conventional method. The mean alignment accuracy was 1.4 mm for the new method, and 2.1 mm for the conventional method on the walls. In the test of the dependency on the light source position error, the mean laser position was shifted just by a similar amount of the shift of the light source in the new method, but it was greatly magnified in the conventional method. In this study, a new laser alignment method was devised and evaluated successfully. The new method provided more accurate, more reproducible, and faster alignment of the lasers than the conventional method.

  2. Inserting Thienyl Linkers into Conjugated Molecules for Efficient Multilevel Electronic Memory: A New Understanding of Charge-Trapping in Organic Materials.

    PubMed

    Li, Yang; Li, Hua; He, Jinghui; Xu, Qingfeng; Li, Najun; Chen, Dongyun; Lu, Jianmei

    2016-03-18

    The practical application of organic memory devices requires low power consumption and reliable device quality. Herein, we report that inserting thienyl units into D-π-A molecules can improve these parameters by tuning the texture of the film. Theoretical calculations revealed that introducing thienyl π bridges increased the planarity of the molecular backbone and extended the D-A conjugation. Thus, molecules with more thienyl spacers showed improved stacking and orientation in the film state relative to the substrates. The corresponding sandwiched memory devices showed enhanced ternary memory behavior, with lower threshold voltages and better repeatability. The conductive switching and variation in the performance of the memory devices were interpreted by using an extended-charge-trapping mechanism. Our study suggests that judicious molecular engineering can facilitate control of the orientation of the crystallite in the solid state to achieve superior multilevel memory performance. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Sealing device for providing a seal in a turbomachine

    DOEpatents

    Lacy, Benjamin Paul; Kottilingam, Srikanth Chandrudu; Porter, Christopher Donald; Schick, David Edward; Weber, David Wayne

    2016-08-16

    Sealing device for providing seals between adjacent components, and turbomachines utilizing such sealing devices, are provided. A sealing device includes a seal plate insertable between the adjacent components, the seal plate comprising a first face and an opposing second face. The sealing device further includes a plurality of pins extending from one of the first face or the second face, the plurality of pins configured to space the one of the first face or the second face from contact surfaces of the adjacent components.

  4. Full scale model investigation on the acoustical protection of a balcony-like façade device (L).

    PubMed

    Tong, Y G; Tang, S K; Yeung, M K L

    2011-08-01

    The acoustical insertion losses produced by a balcony-like structure in front of a window are examined experimentally. The results suggest that the balcony ceiling is the most appropriate location for the installation of artificial sound absorption for the purpose of improving the broadband insertion loss, while the side walls are found to be the second best. Results also indicate that the acoustic modes of the balcony opening and the balcony cavity resonance in a direction normal to the window could have a great impact on the one-third octave band insertion losses. The maximum broadband road traffic noise insertion loss achieved is about 7 dB.

  5. Primary uterine diffuse large B-cell lymphoma (DLBCL) in a patient with prolonged insertion of intrauterine device (IUD).

    PubMed

    Shimizu, Takuya; Hatanaka, Kazuo; Kaneko, Hitomi; Shimada, Toshihide; Imada, Kazunori

    2017-07-01

    A 49-year-old female from China was referred to our hospital after endocervical polypectomy. Twenty years before admission, after the birth of her first child, an intrauterine device (IUD) had been inserted due to the one-child policy in China. She had noticed abnormal vaginal bleeding with a foul smell 3 years before admission. Then the IUD was removed and a polyp was found at the IUD contact site. Two months before admission, endocervical polypectomy was performed. Lymphoma was suspected by histological examination and she was referred to our hospital. Further examination confirmed the diagnosis of primary uterine diffuse large B-cell lymphoma (DLBCL). Subsequently, a combination of three cycles of R-CHOP regimen and involved-field radiation therapy was performed, followed by maintenance therapy with five cycles of rituximab. She has remained in complete remission for over 1 year. This case suggests that chronic inflammation induced by prolonged IUD insertion may contribute to the development of primary uterine lymphoma. To the best of our knowledge, this is the first reported case of DLBCL associated with prolonged IUD insertion.

  6. Atypical use of PICC in infants and small children: a unicentric experience.

    PubMed

    Bernasconi, Filippo; Zanaboni, Clelia; Dato, Andrea; Dolcino, Andrea; Bevilacqua, Michela; Montagnini, Luigi; Disma, Nicola

    2017-11-17

    The peripherally inserted central catheters (PICCs) are vascular access devices (VAD) that are increasingly being used in the pediatric population. If a small vein caliber prevents positioning the catheter in the arm, the following step is to position the same catheter in the supraclavicular area, which can be defined as an off-label use or "atypical" approach, first described by Pittiruti. We retrospectively reviewed PICC positioning with puncture-site in the supra-clavicular area ("atypical" PICC insertion) and then tunneled on the chest. Nineteen atypical PICCs were positioned in 18 patients. The median age of patients at the day of implant was 14 months (IQR 3-27 months), and weight 7.5 kg (IQR 4-12 kg). Within this population, 74% of cases scheduled for a typical PICC insertion presented vein caliber too small for this procedure. For this reason, the typical PICC insertion was changed in favor of an atypical PICC procedure. Atypical PICCs were successfully used in 100% of cases without immediate complications. Atypical PICC positioning is a safe and useful alternative to the conventional technique when there is need for a central vascular access device (CVAD) for mid- or long-term therapy.

  7. Does Needle Rotation Improve Lesion Targeting?

    PubMed Central

    Badaan, Shadi; Petrisor, Doru; Kim, Chunwoo; Mozer, Pierre; Mazilu, Dumitru; Gruionu, Lucian; Patriciu, Alex; Cleary, Kevin; Stoianovici, Dan

    2011-01-01

    Background Image-guided robots are manipulators that operate based on medical images. Perhaps the most common class of image-guided robots are robots for needle interventions. Typically, these robots actively position and/or orient a needle guide, but needle insertion is still done by the physician. While this arrangement may have safety advantages and keep the physician in control of needle insertion, actuated needle drivers can incorporate other useful features. Methods We first present a new needle driver that can actively insert and rotate a needle. With this device we investigate the use of needle rotation in controlled in-vitro experiments performed with a specially developed revolving needle driver. Results These experiments show that needle rotation can improve targeting and may reduce errors by as much as 70%. Conclusion The new needle driver provides a unique kinematic architecture that enables insertion with a compact mechanism. Perhaps the most interesting conclusion of the study is that lesions of soft tissue organs may not be perfectly targeted with a needle without using special techniques, either manually or with a robotic device. The results of this study show that needle rotation may be an effective method of reducing targeting errors. PMID:21360796

  8. Implant Evaluation of an Insertable Cardiac Monitor Outside the Electrophysiology Lab Setting

    PubMed Central

    Pachulski, Roman; Cockrell, James; Solomon, Hemant; Yang, Fang; Rogers, John

    2013-01-01

    Background To date, insertable cardiac monitors (ICM) have been implanted in the hospital without critical evaluation of other potential settings. Providing alternatives to in-hospital insertion may increase access to ICM, decrease waiting times for patients awaiting diagnosis, and reduce hospital resources. Methods This was a prospective, non-randomized, clinical trial involving nine clinical sites throughout the United States designed to assess the feasibility of ICM implants in a non-hospital setting. Other than the Reveal® ICM, implant supplies and techniques were left to physician discretion in patients who met indications. Patients were followed up to 90 days post-implant. The primary objective was to characterize the number of procedure-related adverse events that required surgical intervention within 90 days. Results Sixty-five patients were implanted at nine out-of-hospital sites. The insertion procedure was well tolerated by all patients. There were no deaths, systemic infections or endocarditis. There were two (3%) procedure-related adverse events requiring device explant and four (6%) adverse events not requiring explant. ICM use led to 16 diagnoses (24.6%) with 9 patients proceeding to alternate cardiac device implants during the course of the 90-day follow up. Conclusion Out-of-hospital ICM insertion can be accomplished with comparable procedural safety and represents a reasonable alternative to the in-hospital setting. Clinicaltrials.gov registration number: NCT01168427 PMID:23977071

  9. [Sniffing Position and i-gel Rotation Approach for i-gel Insertion under General Anesthesia].

    PubMed

    Takahashi, Yoshihiro; Murashima, Koji; Kayashima, Kenji

    2016-04-01

    Insertion assistance techniques, such as the sniffing position (SP) and i-gel? rotation approach (RA), are recommended in the i-gel supraglottic airway device insertion manual. The usefulness of these techniques was evaluated, in this study, under general anesthesia. In 50 adult patients, the i-gel was inserted with the patient in the mild-SP with 5 degrees head extention at first attempt. When resistance was encountered during insertion or airway patency was not obtained after insertion, the i-gel was re-inserted with the patient in the full-SP with maximum head extention during second attempt. When re-insertion failed, the i-gel was inserted with the patient in the full-SP and by using the i-gel RA during third attempt. Airway patency was established in the mild-SP in 36 of 50 patients, in the full-SP in 11 of the remaining 14, and in the full-SP with the i-gel RA in the remaining 3. The average insertion time was 24.0 s during the first attempt, 22.2 s during the second, and 18.2 s during the third. No major complications were observed. Both the full-SP and the i-gel RA can be used for i-gel insertion.

  10. 21 CFR 880.5200 - Intravascular catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Devices § 880.5200 Intravascular catheter. (a) Identification. An intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings and that is inserted into the patient's vascular system for short term use (less than 30 days) to sample blood, monitor blood pressure, or...

  11. Capacitorless one-transistor dynamic random-access memory based on asymmetric double-gate Ge/GaAs-heterojunction tunneling field-effect transistor with n-doped boosting layer and drain-underlap structure

    NASA Astrophysics Data System (ADS)

    Yoon, Young Jun; Seo, Jae Hwa; Kang, In Man

    2018-04-01

    In this work, we present a capacitorless one-transistor dynamic random-access memory (1T-DRAM) based on an asymmetric double-gate Ge/GaAs-heterojunction tunneling field-effect transistor (TFET) for DRAM applications. The n-doped boosting layer and gate2 drain-underlap structure is employed in the device to obtain an excellent 1T-DRAM performance. The n-doped layer inserted between the source and channel regions improves the sensing margin because of a high rate of increase in the band-to-band tunneling (BTBT) probability. Furthermore, because the gate2 drain-underlap structure reduces the recombination rate that occurs between the gate2 and drain regions, a device with a gate2 drain-underlap length (L G2_D-underlap) of 10 nm exhibited a longer retention performance. As a result, by applying the n-doped layer and gate2 drain-underlap structure, the proposed device exhibited not only a high sensing margin of 1.11 µA/µm but also a long retention time of greater than 100 ms at a temperature of 358 K (85 °C).

  12. Sealed source and device design safety testing. Technical report on the findings of task 4. Investigation of a failed brachtherapy needle applicator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lukezich, S.J.

    1997-05-01

    As a result of an incident in which a radioactive brachytherapy treatment source was temporarily unable to be retracted, an analysis was performed on the needle applicator used during the treatment. In this report, the results of laboratory evaluations of the physical, mechanical, and metallurgical condition of the subject applicator and two additional applicators are presented. A kink formed in the subject applicator during the incident. The laboratory investigation focused on identifying characteristics which would increase the susceptibility of an applicator to form a kink when subjected to bending loads. The results obtained during this investigation could not conclusively identifymore » the cause of the kink. The subject applicator exhibited no unique features which would have made it particularly susceptible to forming a kink. The three applicators examined represent two methods of manufacturing. A number of characteristics inherent to the method used to manufacture the subject applicator which could lead to an increased susceptibility to the formation of a kink were observed. The use of an insertion device, such as the biopsy needle used during this incident, could also dramatically increase the likelihood of the formation of a kink if the applicator is subjected to bending loads. 33 figs., 4 tabs.« less

  13. Naproxen Sodium for Pain Control With Intrauterine Device Insertion: A Randomized Controlled Trial.

    PubMed

    Ngo, Lynn L; Braaten, Kari P; Eichen, Eva; Fortin, Jennifer; Maurer, Rie; Goldberg, Alisa B

    2016-12-01

    To evaluate whether 550 mg oral naproxen sodium given 1 hour before intrauterine device (IUD) insertion is effective for pain relief as compared with placebo. This was a randomized, double-blind, placebo-controlled trial. The primary outcome was pain with IUD insertion measured on a 100-mm visual analog scale (VAS). Our sample size was calculated to detect a 15-mm difference in VAS scores with 80% power (α=0.05). Secondary outcomes included pain with tenaculum placement, uterine sounding, and 5 and 15 minutes postinsertion. A total of 118 women were enrolled and analyzed (58 in the naproxen sodium arm, 60 in the placebo arm, 97% nulliparous) between May 11, 2015, and March 25, 2016. There were no differences in baseline demographics or reproductive characteristics between arms. There were no differences in median VAS pain scores for the primary outcome of pain with IUD insertion between the naproxen sodium arm compared with the placebo arm (69 compared with 66 mm, P=.89). There were no differences in the secondary outcomes of median VAS pain scores with tenaculum placement (37 compared with 32 mm, P=.97) or uterine sounding (60 compared with 58 mm, P=.66). However, median pain scores postprocedure were lower in the naproxen arm as compared with the placebo arm: 17 compared with 26 mm (P=.01) at 5 minutes and 13 compared with 24 mm (P=.01) at 15 minutes postinsertion. Oral naproxen sodium does not reduce pain with IUD insertion but does reduce pain after insertion and should be considered as a premedication. ClinicalTrials.gov, http://clinicaltrials.gov, NCT02388191.

  14. Primary stability, insertion torque, and bone density of conical implants with internal hexagon: is there a relationship?

    PubMed

    Trisi, Paolo; Berardi, Davide; Paolantonio, Michele; Spoto, Giuseppe; D'Addona, Antonio; Perfetti, Giorgio

    2013-05-01

    Between implants and peri-implant bone, there should be a minimum gap, without micromotions over a threshold, which could cause resorption and fibrosis. The higher the implant insertion torque, the higher will be the initial stability. The aim was to evaluate in vitro the correlation between micromotions and insertion torque of implants in bone of different densities. The test was performed on bovine bone of hard, medium, and soft density: 150 implants were used, 10 for each torque (20, 35, 45, 70, and 100 N/cm). Samples were fixed on a loading device. On each sample, we applied a 25-N horizontal force. Insertion torque and micromotions are statistically correlated. In soft bone with an insertion force of 20 and 35 N/cm, the micromotion resulted significantly over the risk threshold, which was not found with an insertion force of 45 and 70 N/cm and in hard and medium bones with any insertion torque. The increase in insertion torque reduces the amount of micromotions between implant and bone. Therefore, the immediate loading may be considered a valid therapeutic choice, even in low-density bone, as long as at least 45 N/cm of insertion torque is reached.

  15. Penile Lengthening, Girth, and Size Preservation at the Time of Penile Prosthesis Insertion.

    PubMed

    Tran, Henry; Goldfarb, Robert; Ackerman, Anika; Valenzuela, Robert J

    2017-07-01

    Penile prosthetic devices are the gold standard treatment of medication-refractory erectile dysfunction. Inflatable penile prosthetic (IPP) devices have been available and used for more than four decades. Oftentimes, medical conditions causing erectile dysfunction also cause penile shortening, causing decreased patient quality of life. To identify and review all available penile lengthening procedures that can be performed at time of IPP insertion. An extensive, systematic literature review was performed using PubMed searching for key terms penile lengthening, inflatable penile prosthesis, penile girth, corporoplasty, glans augmentation, and penile enhancement; all articles with subjective and/or objective penile length outcomes were reviewed. A review of various techniques for penile length and girth preservation and enhancement during penile prosthesis insertion. Several advanced and novel techniques were found for penile length preservation and enhancement at time of IPP insertion, including the sub-coronal IPP insertion technique, and adjuvant maneuvers during insertion, such as the sliding technique, modified sliding technique, multiple slice technique, and circumferential incision and grafting. Other adjuvant techniques that can enhance perception of increased length include ventral phalloplasty, suprapubic lipectomy, and suspensory ligament release. Further enhancement can be obtained using augmentation corporoplasty and glans augmentation with hyaluronic acid and other fillers. The different techniques vary in complexity and could require specialized training and experience. Maximum length gain appears to be limited by the length of the neurovascular bundles. Overall, surgical penile lengthening procedures at time of IPP insertion appear safe and effective for treatment of patients with penile shortening and severe erectile dysfunction. These therapies can significantly improve patient self-esteem and quality of life in properly selected patients. Tran H, Goldfarb R, Ackerman A, Valenxuela RJ. Penile Lengthening, Girth and Size Preservation at the Time of Penile Prosthesis Insertion. Sex Med Rev 2017;5:403-412. Copyright © 2017 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  16. Evaluation of a novel, ultrathin, tip-bending endoscope in a synthetic force-sensing pancreas with comparison to medical guide wires

    PubMed Central

    Chandler, John E; Lee, Cameron M; Babchanik, Alexander P; Melville, C David; Saunders, Michael D; Seibel, Eric J

    2012-01-01

    Purpose Direct visualization of pancreatic ductal tissue is critical for early diagnosis of pancreatic diseases and for guiding therapeutic interventions. A novel, ultrathin (5 Fr) scanning fiber endoscope (SFE) with tip-bending capability has been developed specifically to achieve high resolution imaging as a pancreatoscope during endoscopic retrograde cholangiopancreatography (ERCP). This device has potential to dramatically improve both diagnostic and therapeutic capabilities during ERCP by providing direct video feedback and tool guidance to clinicians. Methods Invasiveness of the new tip-bending SFE was evaluated by a performance comparison to ERCP guide wires, which are routinely inserted into the pancreatic duct during ERCP. An in vitro test model with four force sensors embedded in a synthetic pancreas was designed to detect and compare the insertion forces for 0.89 mm and 0.53 mm diameter guide wires as well as the 1.7 mm diameter SFE. Insertions were performed through the working channel of a therapeutic duodenoscope for the two types of guide wires and using a statistically similar direct insertion method for comparison to the SFE. Results Analysis of the forces detected by the sensors showed the smaller diameter 0.53 mm wire produced significantly less average and maximum forces during insertion than the larger diameter 0.89 mm wire. With the use of tip-bending and optical visualization, the 1.7 mm diameter SFE produced significantly less average force during insertion than the 0.89 mm wire at every sensor, despite its larger size. It was further shown that the use of tip-bending with the SFE significantly reduced the forces at all sensors, compared to insertions when tip-bending was not used. Conclusion Combining high quality video imaging with two-axis tip-bending allows a larger diameter guide wire-style device to be inserted into the pancreatic duct during ERCP with improved capacity to perform diagnostics and therapy. PMID:23166452

  17. Polymer electro-optic waveguide devices: Low-loss etchless fabrication techniques and passive-to-active integration

    NASA Astrophysics Data System (ADS)

    Geary, Kevin

    The development of high-frequency polymer electro-optic modulators has seen steady and significant progress in recent years, yet applications of these promising materials to more complicated integrated optic structures and arrays of devices have been limited primarily due to high optical waveguide loss characteristics. This is unfortunate since a major advantage of polymers as photonic materials is their compatibility with photolithographic processing of large components. In this Dissertation, etchless waveguide writing techniques are presented in order to improve the overall optical insertion loss of electro-optic polymer waveguide devices. These techniques include poling-induced writing, stress-induced waveguide writing, and photobleaching. Using these waveguide writing mechanisms, we have demonstrated straight waveguides, phase modulators, Mach-Zehnder intensity modulators, variable optical attenuators, and multimode interference (MMI) power splitters, all with improved loss characteristics over their etched rib waveguide counterparts. Ultimately, the insertion loss of an integrated optic device is limited by the actual material loss of the core waveguide material. In this Dissertation, passive-to-active polymer waveguide transitions are proposed to circumvent this problem. These transitions are compact, in-plane, self-aligned, and require no tapering of any physical dimensions of the waveguides. By utilizing both the time-dependent and intensity-dependent photobleaching characteristics of electro-optic polymer materials, adiabatic refractive index tapers can be seamlessly coupled to in-plane butt couple transitions, resulting in losses as low as 0.1 dB per interface. By integrating passive polymer planar lightwave circuits with the high-speed phase shifting capability of electro-optic polymers, active wideband photonic devices of increased size and complexity can be realized. Optical fiber-to-device coupling can also result in significant contributions to the overall insertion loss of an integrated electro-optic polymer device. In this Dissertation, we leverage the photobleached refractive index taper component of our proposed passive-to-active polymer waveguide transitions in order to realize a two-dimensional optical mode transformer for improved overall fiber-to-device coupling of electro-optic polymer waveguide devices.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chan, Gabriel, E-mail: dr.changabriel@gmail.com; Quek, Lawrence Hwee Han, E-mail: lawrence-quek@ttsh.com.sg; Tan, Glenn Leong Wei, E-mail: glenn-tan@ttsh.com.sg

    BackgroundInsertion of a carotid chimney graft during thoracic endovascular aortic repair (Ch-TEVAR) is a recognized technique to extend the proximal landing zone into the aortic arch in the treatment of thoracic aortic disease. Conventional technique requires surgical exposure of the carotid artery for insertion of the carotid chimney graft.MethodologyWe describe our experience in the use of a suture-mediated closure device in percutaneous Ch-TEVAR in four patients.ResultsSuccessful hemostasis was achieved in all four patients. No complications related to the carotid puncture were recorded.ConclusionWe conclude that using suture-mediated closure device for carotid closure appears feasible and deserves further studies as a potentialmore » alternative to conventional surgical approach.« less

  19. A Novel Coupled Resonator Photonic Crystal Design in Lithium Niobate for Electrooptic Applications

    DOE PAGES

    Ozturk, Birol; Yavuzcetin, Ozgur; Sridhar, Srinivas

    2015-01-01

    High-aspect-ratio photonic crystal air-hole fabrication on bulk Lithium Niobate (LN) substrates is extremely difficult due to its inherent resistance to etching, resulting in conical structures and high insertion losses. Here, we propose a novel coupled resonator photonic crystal (CRPC) design, combining a coupled resonator approach with that of Bragg gratings. CRPC design parameters were optimized by analytical calculations and FDTD simulations. CRPC structures with optimized parameters were fabricated and electrooptically tested on bulk LN annealed proton exchange waveguides. Low insertion loss and large electrooptic effect were observed with the fabricated devices, making the CRPC design a promising structure for electroopticmore » device applications.« less

  20. Cervix-to-rectum measuring device in a radiation applicator for use in the treatment of cervical cancer

    NASA Technical Reports Server (NTRS)

    Fischell, D. R.; Mazique, J. C. (Inventor)

    1981-01-01

    A cervix-to-rectum measuring device to be used in the treatment of cervical cancer is described. It includes a handle and a probe pivotably connected to the handle for insertion in the rectum. The measuring device further includes means for coupling the handle to an intrauterine radiation applicator when the latter is positioned in the uterine cervix and the probe is inserted in the rectum to pivot the handle about the probe. A gear is provided which is adapted to pivot with the probe. A pinion pivotably connected to the handle meshes with the gear. A pointer fixed to the pinion is displaced in response to the pivoting of the handle about the probe, and this displacement can be read from a scale on the handle, providing an indication of the cervix-to-rectum distance.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strelnikov, N.; Vasserman, I.; Xu, J.

    As part of the R&D program of the LCLS-II project, a novel 3.4-meter-long undulator prototype with horizontal magnetic field and dynamic force compensation has recently been developed at the Advanced Photon Source (APS). Some previous steps in this development were the shorter 0.8-meter-long and 2.8-meter-long prototypes. Extensive mechanical and magnetic testing was carried out for each prototype, and each prototype was magnetically tuned using magnetic shims. Furthermore, the resulting performance of the 3.4-meter-long undulator prototype meets all requirements for the LCLS-II insertion device, including limits on the field integrals, phase errors, higher-order magnetic moments, and electron-beam trajectory for all operationalmore » gaps, as well as the reproducibility and accuracy of the gap settings.« less

  2. Selected tether applications in space: Phase 2. Executive summary

    NASA Technical Reports Server (NTRS)

    Thorson, M. H.; Lippy, L. J.

    1985-01-01

    The application of tether technology has the potential to increase the overall performance efficiency and capability of the integrated space operations and transportation systems through the decade of the 90s. The primary concepts for which significant economic benefits were identified are dependent on the space station as a storage device for angular momentum and as an operating base for the tether system. Concepts examined include: (1) tether deorbit of shuttle from space station; (2) tethered orbit insertion of a spacecraft from shuttle; (3) tethered platform deployed from space station; (4) tether-effected rendezvous of an OMV with a returning OTV; (5) electrodynamic tether as an auxiliary power source for space station; and (6) tether assisted launch of an OTV mission from space station.

  3. Aqueous rechargeable zinc/sodium vanadate batteries with enhanced performance from simultaneous insertion of dual carriers.

    PubMed

    Wan, Fang; Zhang, Linlin; Dai, Xi; Wang, Xinyu; Niu, Zhiqiang; Chen, Jun

    2018-04-25

    Rechargeable aqueous zinc-ion batteries are promising energy storage devices due to their high safety and low cost. However, they remain in their infancy because of the limited choice of positive electrodes with high capacity and satisfactory cycling performance. Furthermore, their energy storage mechanisms are not well established yet. Here we report a highly reversible zinc/sodium vanadate system, where sodium vanadate hydrate nanobelts serve as positive electrode and zinc sulfate aqueous solution with sodium sulfate additive is used as electrolyte. Different from conventional energy release/storage in zinc-ion batteries with only zinc-ion insertion/extraction, zinc/sodium vanadate hydrate batteries possess a simultaneous proton, and zinc-ion insertion/extraction process that is mainly responsible for their excellent performance, such as a high reversible capacity of 380 mAh g -1 and capacity retention of 82% over 1000 cycles. Moreover, the quasi-solid-state zinc/sodium vanadate hydrate battery is also a good candidate for flexible energy storage device.

  4. 21 CFR 874.4710 - Esophagoscope (flexible or rigid) and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... disease, or to remove foreign bodies from the esophagus. When inserted, the device extends from the area.... 874.4710 Section 874.4710 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... generic type of device includes the flexible foreign body claw, flexible biopsy forceps, rigid biopsy...

  5. 21 CFR 874.4710 - Esophagoscope (flexible or rigid) and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... disease, or to remove foreign bodies from the esophagus. When inserted, the device extends from the area.... 874.4710 Section 874.4710 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... generic type of device includes the flexible foreign body claw, flexible biopsy forceps, rigid biopsy...

  6. 21 CFR 874.4710 - Esophagoscope (flexible or rigid) and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... disease, or to remove foreign bodies from the esophagus. When inserted, the device extends from the area.... 874.4710 Section 874.4710 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... generic type of device includes the flexible foreign body claw, flexible biopsy forceps, rigid biopsy...

  7. Micro-device for coupling, multiplexing and demultiplexing using elliptical-core two-mode fiber

    NASA Technical Reports Server (NTRS)

    Wang, A.; Murphy, K. A.; Wang, G. Z.; Vengsarkar, A. M.; Claus, R. O.

    1990-01-01

    We propose and demonstrate experimentally a fiber optic micro-device that is capable of tunably splitting, multiplexing, and demultiplexing optical signals using elliptical-core two-mode optical fiber. A crosstalk of 15 dB with an insertion loss of 1.2 dB was obtained.

  8. DESIGN OF A HIGH COMPRESSION, DIRECT INJECTION, SPARK-IGNITION, METHANOL FUELED RESEARCH ENGINE WITH AN INTEGRAL INJECTOR-IGNITION SOURCE INSERT, SAE PAPER 2001-01-3651

    EPA Science Inventory

    A stratified charge research engine and test stand were designed and built for this work. The primary goal of this project was to evaluate the feasibility of using a removal integral injector ignition source insert which allows a convenient method of charging the relative locat...

  9. 77 FR 27788 - Notice of Issuance of Final Determination Concerning Special Ops Flashlights and Sportsman...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-11

    ... create a slight V shape; inserting the PCB into the battery tube; inserting the 3 V Lithium battery into... items are attached together. The power source used for the LED blank assemblies is a 3 volt lithium battery which is imported separately and sourced from China. The battery is attached to the LED blank in...

  10. Reticular telangiectatic erythema: case report and literature review

    PubMed Central

    Beutler, Bryce D.; Cohen, Philip R.

    2015-01-01

    Background: Reticular telangiectatic erythema is a benign cutaneous reaction that may occur in patients who have received a subcutaneous implantable cardioverter-defibrillator. Reticular telangiectatic erythema is characterized by asymptomatic telangiectasias, blanchable erythematous patches, or both overlying and/or adjacent to the subcutaneous implantable cardioverter-defibrillator. Purpose: We describe a man who developed reticular telangiectatic erythema after receiving a subcutaneous implantable cardioverter-defibrillator and review the salient features of this condition. We also summarize the conditions that can mimic reticular telangiectatic erythema. Materials and methods: The features of a man with reticular telangiectatic erythema are presented and the literature on reticular telangiectatic erythema is reviewed. Results: Our patient developed reticular telangiectatic erythema within one month of subcutaneous implantable cardioverter-defibrillator insertion. The subcutaneous manifestations were asymptomatic. The patient concurred to have periodic clinical follow up and his condition will be monitored for any changes. Conclusion: Reticular telangiectatic erythema is a benign condition characterized by the development of erythema, telangiectasia, or both following insertion of a subcutaneous implantable cardioverter-defibrillator. Other subcutaneous implantable cardioverter-defibrillator-related side effects, such as pressure dermatitis and contact dermatitis, can mimic the condition. Reticular telangiectatic erythema can also be observed following insertion of other devices or, rarely, in the absence of inserted devices. Local microcirculatory changes and subcutaneous implantable cardioverter-defibrillator-related obstruction of blood flow have been suggested as possible mechanisms of pathogenesis. The diagnosis can usually be established by clinical presentation. Therefore, patch testing can usually be omitted. Reticular telangiectatic erythema is typically asymptomatic and thus removal of the device is not required. PMID:25692087

  11. Suite of three protein crystallography beamlines with single superconducting bend magnet as the source.

    PubMed

    MacDowell, Alastair A; Celestre, Rich S; Howells, Malcolm; McKinney, Wayne; Krupnick, James; Cambie, Daniella; Domning, Edward E; Duarte, Robert M; Kelez, Nicholas; Plate, David W; Cork, Carl W; Earnest, Thomas N; Dickert, Jeffery; Meigs, George; Ralston, Corie; Holton, James M; Alber, Tom; Berger, James M; Agard, David A; Padmore, Howard A

    2004-11-01

    At the Advanced Light Source, three protein crystallography beamlines have been built that use as a source one of the three 6 T single-pole superconducting bending magnets (superbends) that were recently installed in the ring. The use of such single-pole superconducting bend magnets enables the development of a hard X-ray program on a relatively low-energy 1.9 GeV ring without taking up insertion-device straight sections. The source is of relatively low power but, owing to the small electron beam emittance, it has high brightness. X-ray optics are required to preserve the brightness and to match the illumination requirements for protein crystallography. This was achieved by means of a collimating premirror bent to a plane parabola, a double-crystal monochromator followed by a toroidal mirror that focuses in the horizontal direction with a 2:1 demagnification. This optical arrangement partially balances aberrations from the collimating and toroidal mirrors such that a tight focused spot size is achieved. The optical properties of the beamline are an excellent match to those required by the small protein crystals that are typically measured. The design and performance of these new beamlines are described.

  12. Main functions, recent updates, and applications of Synchrotron Radiation Workshop code

    NASA Astrophysics Data System (ADS)

    Chubar, Oleg; Rakitin, Maksim; Chen-Wiegart, Yu-Chen Karen; Chu, Yong S.; Fluerasu, Andrei; Hidas, Dean; Wiegart, Lutz

    2017-08-01

    The paper presents an overview of the main functions and new application examples of the "Synchrotron Radiation Workshop" (SRW) code. SRW supports high-accuracy calculations of different types of synchrotron radiation, and simulations of propagation of fully-coherent radiation wavefronts, partially-coherent radiation from a finite-emittance electron beam of a storage ring source, and time-/frequency-dependent radiation pulses of a free-electron laser, through X-ray optical elements of a beamline. An extended library of physical-optics "propagators" for different types of reflective, refractive and diffractive X-ray optics with its typical imperfections, implemented in SRW, enable simulation of practically any X-ray beamline in a modern light source facility. The high accuracy of calculation methods used in SRW allows for multiple applications of this code, not only in the area of development of instruments and beamlines for new light source facilities, but also in areas such as electron beam diagnostics, commissioning and performance benchmarking of insertion devices and individual X-ray optical elements of beamlines. Applications of SRW in these areas, facilitating development and advanced commissioning of beamlines at the National Synchrotron Light Source II (NSLS-II), are described.

  13. Skeletal anchorage for everybody? a questionnaire study on frequency of use and clinical indications in daily practice.

    PubMed

    Bock, N C; Ruf, S

    2015-03-01

    The purpose of this survey was to determine how commonly, and in what clinical situations, German-based orthodontists use skeletal anchorage devices in daily clinical practice. In early 2013, a set of questionnaires on the subject of skeletal anchorage devices was mailed to 2459 members of the German Orthodontic Society (Deutsche Gesellschaft für Kieferorthopädie, DGKFO). The questions dealt separately with mini screws (MSCs) and osseointegrated palatal implants (OPIs). The addresses were asked whether or not, as well as how frequently and in what clinical situations, they used these MSCs and/or OPIs, what their experience was, and to elaborate on their reasons for using or not using these devices. The rate of returned questionnaires was 48 %. To correctly interpret our data, it should be kept in mind that an unknown number of respondents did not distinguish between OPIs and palatally inserted MSCs. Overall, 62 % indicated that they did use MSCs and/or OPIs, although most of them (> 50 %) infrequently (≤ 2 new patients/3 months). Only ≤ 2 % were frequent users (> 2 new patients/week). While most users (> 70 %) indicated that their experience was mostly good, only ≤ 50 % considered the devices easy and trouble-free to use in daily clinical practice. The median percentage of insertion procedures conducted by the respondents themselves was 2 % for MSCs and 0 % for OPIs. Many of the non-users indicated that their treatment concept did not include suitable clinical indications (≥ 50 %), expressed skepticism about the success rates (56 % of MSC and 21 % of OPI non-users), or thought that the insertion procedures involved were too complex or time-consuming (33 % of MSC and 56 % of OPI non-users). A total of 62 % of German-based orthodontists participating in this survey indicated using skeletal anchorage devices, although most of them infrequently. Major reasons for non-use were lack of clinical indications, skepticism about the success rate of MSCs, and overly complex or time-consuming procedures of surgical OPI insertion.

  14. Peapod-like Li3 VO4 /N-Doped Carbon Nanowires with Pseudocapacitive Properties as Advanced Materials for High-Energy Lithium-Ion Capacitors.

    PubMed

    Shen, Laifa; Lv, Haifeng; Chen, Shuangqiang; Kopold, Peter; van Aken, Peter A; Wu, Xiaojun; Maier, Joachim; Yu, Yan

    2017-07-01

    Lithium ion capacitors are new energy storage devices combining the complementary features of both electric double-layer capacitors and lithium ion batteries. A key limitation to this technology is the kinetic imbalance between the Faradaic insertion electrode and capacitive electrode. Here, we demonstrate that the Li 3 VO 4 with low Li-ion insertion voltage and fast kinetics can be favorably used for lithium ion capacitors. N-doped carbon-encapsulated Li 3 VO 4 nanowires are synthesized through a morphology-inheritance route, displaying a low insertion voltage between 0.2 and 1.0 V, a high reversible capacity of ≈400 mAh g -1 at 0.1 A g -1 , excellent rate capability, and long-term cycling stability. Benefiting from the small nanoparticles, low energy diffusion barrier and highly localized charge-transfer, the Li 3 VO 4 /N-doped carbon nanowires exhibit a high-rate pseudocapacitive behavior. A lithium ion capacitor device based on these Li 3 VO 4 /N-doped carbon nanowires delivers a high energy density of 136.4 Wh kg -1 at a power density of 532 W kg -1 , revealing the potential for application in high-performance and long life energy storage devices. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Microanalysis of extended-test xenon hollow cathodes

    NASA Technical Reports Server (NTRS)

    Verhey, Timothy R.; Patterson, Michael J.

    1991-01-01

    Four hollow cathode electron sources were analyzed via boroscopy, scanning electron microscopy, energy dispersive x ray analysis, and x ray diffraction analysis. These techniques were used to develop a preliminary understanding of the chemistry of the devices that arise from contamination due to inadequate feed-system integrity and improper insert activation. Two hollow cathodes were operated in an ion thruster simulator at an emission current of 23.0 A for approximately 500 hrs. The two tests differed in propellant-feed systems, discharge power supplies, and activation procedures. Tungsten deposition and barium tungstate formation on the internal cathode surfaces occurred during the first test, which were believed to result from oxygen contamination of the propellant feed-system. Consequently, the test facility was upgraded to reduce contamination, and the test was repeated. The second hollow cathode was found to have experienced significantly less tungsten deposition. A second pair of cathodes examined were the discharge and the neutralizer hollow cathodes used in a life-test of a 30-cm ring-cusp ion thruster at a 5.5 kW power level. The cathodes' test history was documented and the post-test microanalyses are described. The most significant change resulting from the life-test was substantial tungsten deposition on the internal cathode surfaces, as well as removal of material from the insert surface. In addition, barium tungstate and molybdate were found on insert surfaces. As a result of the cathode examinations, procedures and approaches were proposed for improved discharge ignition and cathode longevity.

  16. Novel Sternal Protection Device for Cardiac Surgery Via Median Sternotomy Incision

    PubMed Central

    Marasco, Silvana F.; McGiffin, David C.; Zimmet, Adam D.; Solis, Pablo C.; Bingham, Judy M.; Moshinsky, Randall A.

    2017-01-01

    Objective Sternal bleeding during cardiac surgery is currently controlled using bone wax or other chemical substances that may result in adverse effects and affect wound healing and recovery. The purpose of this study was to identify a safe, cost-effective, and easy-to-use technique to reduce sternal bleeding and sternal trauma during cardiac surgery. Methods After sternotomy, a sternal protection device was placed over each hemisternal section before insertion of the retractor and remained in situ until the end of surgery. Sternal bleeding and ease of use were assessed and recorded during surgery. Sternal trauma was assessed and recorded within 5 minutes of removal of the device, and overall satisfaction (Global Impression) and any intraoperative adverse events or device malfunction were reported at surgery completion. Patients were followed up 24 hours and 4 weeks after surgery. Results Twelve patients completed the study. Adverse events reported were not considered related to the device. No sternal trauma was identified in any patient. In 9 of 11 patients, sternal bleeding was reduced after insertion of the device. The device was generally considered easy to use, although some difficulty was encountered when used with the Internal Mammary Artery retractor. Conclusions Our data suggest that the device is safe and able to reduce sternal bleeding during surgery using sternal retractors. We recommend further studies in a larger population of patients with a control group to evaluate the device's ability to reduce the morbidity associated with sternal bleeding and sternal trauma. PMID:29023352

  17. Novel Sternal Protection Device for Cardiac Surgery Via Median Sternotomy Incision.

    PubMed

    Marasco, Silvana F; McGiffin, David C; Zimmet, Adam D; Solis, Pablo C; Bingham, Judy M; Moshinsky, Randall A

    Sternal bleeding during cardiac surgery is currently controlled using bone wax or other chemical substances that may result in adverse effects and affect wound healing and recovery. The purpose of this study was to identify a safe, cost-effective, and easy-to-use technique to reduce sternal bleeding and sternal trauma during cardiac surgery. After sternotomy, a sternal protection device was placed over each hemisternal section before insertion of the retractor and remained in situ until the end of surgery. Sternal bleeding and ease of use were assessed and recorded during surgery. Sternal trauma was assessed and recorded within 5 minutes of removal of the device, and overall satisfaction (Global Impression) and any intraoperative adverse events or device malfunction were reported at surgery completion. Patients were followed up 24 hours and 4 weeks after surgery. Twelve patients completed the study. Adverse events reported were not considered related to the device. No sternal trauma was identified in any patient. In 9 of 11 patients, sternal bleeding was reduced after insertion of the device. The device was generally considered easy to use, although some difficulty was encountered when used with the Internal Mammary Artery retractor. Our data suggest that the device is safe and able to reduce sternal bleeding during surgery using sternal retractors. We recommend further studies in a larger population of patients with a control group to evaluate the device's ability to reduce the morbidity associated with sternal bleeding and sternal trauma.

  18. Verifying placement of small-bore feeding tubes: electromagnetic device images versus abdominal radiographs.

    PubMed

    Bryant, Vera; Phang, Jean; Abrams, Kevin

    2015-11-01

    Clinicians are unsure if radiography is needed to confirm correct positioning of feeding tubes inserted with assistance from an electromagnetic system. To compare radiographic reports of feeding tube placement with images generated by an electromagnetic feeding tube placement device. The medical records of 200 consecutive patients who had feeding tubes inserted with assistance from an electromagnetic feeding tube placement device were reviewed retrospectively. Radiographic reports of tube site were compared with images generated by the device. Radiographic evidence of tube sites was available in 188 cases: 184 tubes were located in portions of the gastrointestinal tract. Ninety of the 188 tubes were situated in the optimal site (distal duodenum or jejunum) radiographically. Images generated by the electromagnetic device were available in 176 cases; of these, 52 tubes appeared to end in the expected left lower quadrant. Tubes shown on radiographs to be in other sites also occasionally appeared to end in the left lower quadrant. Nurses using the device did not recognize 4 of the 188 tubes (2.1%) that were inadvertently placed in the lung. No consistent pattern of quadrant distribution was found for tubes positioned in the stomach or proximal duodenum. Images generated by the electromagnetic tube placement device provided inconsistent results regarding tube location. A small percentage of seriously malpositioned tubes were not detected by using the electromagnetic device. These findings do not support eliminating radiographs to confirm correct tube placement following use of an electromagnetic tube placement device. ©2015 American Association of Critical-Care Nurses.

  19. [The ISP (Safe Insertion of PICCs) protocol: a bundle of 8 recommendations to minimize the complications related to the peripherally inserted central venous catheters (PICC)].

    PubMed

    Emoli, Alessandro; Cappuccio, Serena; Marche, Bruno; Musarò, Andrea; Scoppettuolo, Giancarlo; Pittiruti, Mauro

    2014-01-01

    The ISP (Safe Insertion of PICCs) protocol: a bundle of 8 recommendations to minimize the complications related to the peripherally inserted central venous catheters (PICC). The insertion of a peripherally inserted central venous catheter (PICC) is not without risks. The Italian Group for the Study of Long-Term Central Venous Access Devices (GAVeCeLT) has developed a protocol (SIP: Safe Implantation of PICCs) with the aim of minimizing the risks which may be associated with the placement of PICCs. The protocol is based on recommendations available in the literature and on the main clinical practice guidelines. The SIP protocol, a bundle of evidence-based recommendations, it is is easy to use, inexpensive, and cost-effective. If routinely used and carefully inplemented, it greatly reduces complications such as failure of venipuncture, accidental arterial puncture, damage of median nerve, infection and catheter related venous thrombosis.

  20. SU-G-IeP2-15: Virtual Insertion of Digital Kidney Stones Into Dual-Source, Dual- Energy CT Projection Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferrero, A; Chen, B; Huang, A

    Purpose: In order to investigate novel methods to more accurately estimate the mineral composition of kidney stones using dual energy CT, it is desirable to be able to combine digital stones of known composition with actual phantom and patient scan data. In this work, we developed and validated a method to insert digital kidney stones into projection data acquired on a dual-source, dual-energy CT system. Methods: Attenuation properties of stones of different mineral composition were computed using tabulated mass attenuation coefficients, the chemical formula for each stone type, and the effective beam energy at each evaluated tube potential. A previouslymore » developed method to insert lesions into x-ray CT projection data was extended to include simultaneous dual-energy CT projections acquired on a dual-source gantry (Siemens Somatom Flash). Digital stones were forward projected onto both detectors and the resulting projections added to the physically acquired sinogram data. To validate the accuracy of the technique, digital stones were inserted into different locations in the ACR CT accreditation phantom; low and high contrast resolution, CT number accuracy and noise properties were compared before and after stone insertion. The procedure was repeated for two dual-energy tube potential pairs in clinical use on the scanner, 80/Sn140 kV and 100/Sn140 kV, respectively. Results: The images reconstructed after the insertion of digital kidney stones were consistent with the images reconstructed from the scanner. The largest average CT number difference for the 4 insert in the CT number accuracy module of the phantom was 3 HU. Conclusion: A framework was developed and validated for the creation of digital kidney stones of known mineral composition, and their projection-domain insertion into commercial dual-source, dual-energy CT projection data. This will allow a systematic investigation of the impact of scan and reconstruction parameters on stone attenuation and dual-energy behavior under rigorously controlled conditions. Dr. McCollough receives research support from Siemens Healthcare.« less

  1. A Diffusion-Based and Dynamic 3D-Printed Device That Enables Parallel in Vitro Pharmacokinetic Profiling of Molecules

    PubMed Central

    Lockwood, Sarah Y.; Meisel, Jayda E.; Monsma, Frederick J.; Spence, Dana M.

    2016-01-01

    The process of bringing a drug to market involves many steps, including the preclinical stage, where various properties of the drug candidate molecule are determined. These properties, which include drug absorption, distribution, metabolism, and excretion, are often displayed in a pharmacokinetic (PK) profile. While PK profiles are determined in animal models, in vitro systems that model in vivo processes are available, although each possesses shortcomings. Here, we present a 3D-printed, diffusion-based, and dynamic in vitro PK device. The device contains six flow channels, each with integrated porous membrane-based insert wells. The pores of these membranes enable drugs to freely diffuse back and forth between the flow channels and the inserts, thus enabling both loading and clearance portions of a standard PK curve to be generated. The device is designed to work with 96-well plate technology and consumes single-digit milliliter volumes to generate multiple PK profiles, simultaneously. Generation of PK profiles by use of the device was initially performed with fluorescein as a test molecule. Effects of such parameters as flow rate, loading time, volume in the insert well, and initial concentration of the test molecule were investigated. A prediction model was generated from this data, enabling the user to predict the concentration of the test molecule at any point along the PK profile within a coefficient of variation of ~5%. Depletion of the analyte from the well was characterized and was determined to follow first-order rate kinetics, indicated by statistically equivalent (p > 0.05) depletion half-lives that were independent of the starting concentration. A PK curve for an approved antibiotic, levofloxacin, was generated to show utility beyond the fluorescein test molecule. PMID:26727249

  2. Microfluidic transwell inserts for generation of tissue culture-friendly gradients in well plates

    PubMed Central

    Sip, Christopher G.; Bhattacharjee, Nirveek; Folch, Albert

    2015-01-01

    Gradients of biochemical molecules play a key role in many physiological processes such as axon growth, tissue morphogenesis, and trans-epithelium nutrient transport, as well as in pathophysiological phenomena such as wound healing, immune response, bacterial invasion, and cancer metastasis. In this paper, we report a microfluidic transwell insert for generating quantifiable concentration gradients in a user-friendly and modular format that is compatible with conventional cell cultures and with tissue explant cultures. The device is simply inserted into a standard 6-well plate, where it hangs self-supported at a distance of ~250 μm above the cell culture surface. The gradient is created by small microflows from the device, through an integrated track-etched porous membrane, into the cell culture well. The microfluidic transwell can deliver stable, quantifiable gradients over a large area with extremely low fluid shear stress to dissociated cells or tissue explants cultured independently on the surface of a 6-well plate. We used finite-element modeling to describe the porous membrane flow and molecular transport and to predict gradients generated by the device. Using the device, we applied a gradient of the chemotactic peptide N-Formyl-Met-Leu-Phe (fMLP) to a large population of HL-60 cells (a neutrophil cell line) and directly observed the migration with time-lapse microscopy. On quantification of the chemotactic response with an automated tracking algorithm, we found 74% of the cells moving towards the gradient. Additionally, the modular design and low fluid shear stress made it possible to apply gradients of growth factors and second messengers to mouse retinal explant cultures. With a simplified interface and well-defined gradients, the microfluidic transwell device has potential for broad applications to gradient-sensing biology. PMID:24225908

  3. Robot-assisted real-time magnetic resonance image-guided transcatheter aortic valve replacement.

    PubMed

    Miller, Justin G; Li, Ming; Mazilu, Dumitru; Hunt, Tim; Horvath, Keith A

    2016-05-01

    Real-time magnetic resonance imaging (rtMRI)-guided transcatheter aortic valve replacement (TAVR) offers improved visualization, real-time imaging, and pinpoint accuracy with device delivery. Unfortunately, performing a TAVR in a MRI scanner can be a difficult task owing to limited space and an awkward working environment. Our solution was to design a MRI-compatible robot-assisted device to insert and deploy a self-expanding valve from a remote computer console. We present our preliminary results in a swine model. We used an MRI-compatible robotic arm and developed a valve delivery module. A 12-mm trocar was inserted in the apex of the heart via a subxiphoid incision. The delivery device and nitinol stented prosthesis were mounted on the robot. Two continuous real-time imaging planes provided a virtual real-time 3-dimensional reconstruction. The valve was deployed remotely by the surgeon via a graphic user interface. In this acute nonsurvival study, 8 swine underwent robot-assisted rtMRI TAVR for evaluation of feasibility. Device deployment took a mean of 61 ± 5 seconds. Postdeployment necropsy was performed to confirm correlations between imaging and actual valve positions. These results demonstrate the feasibility of robotic-assisted TAVR using rtMRI guidance. This approach may eliminate some of the challenges of performing a procedure while working inside of an MRI scanner, and may improve the success of TAVR. It provides superior visualization during the insertion process, pinpoint accuracy of deployment, and, potentially, communication between the imaging device and the robotic module to prevent incorrect or misaligned deployment. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  4. Acid-triggered membrane insertion of Pseudomonas exotoxin A involves an original mechanism based on pH-regulated tryptophan exposure.

    PubMed

    Méré, Jocelyn; Morlon-Guyot, Juliette; Bonhoure, Anne; Chiche, Laurent; Beaumelle, Bruno

    2005-06-03

    Exposure to low endosomal pH during internalization of Pseudomonas exotoxin A (PE) triggers membrane insertion of its translocation domain. This process is a prerequisite for PE translocation to the cytosol where it inactivates protein synthesis. Although hydrophobic helices enable membrane insertion of related bacterial toxins such as diphtheria toxin, the PE translocation domain is devoid of hydrophobic stretches and the structural features triggering acid-induced membrane insertion of PE are not known. Here we have identified a molecular device that enables PE membrane insertion. This process is promoted by exposure of a key tryptophan residue. At neutral pH, this Trp is buried in a hydrophobic pocket closed by the smallest alpha-helix of the translocation domain. Upon acidification, protonation of the Asp that is the N-cap residue of the helix leads to its destabilization, enabling Trp side chain insertion into the endosome membrane. This tryptophan-based membrane insertion system is surprisingly similar to the membrane-anchoring mechanism of human annexin-V and could be used by other proteins as well.

  5. Postplacental or Delayed Insertion of the Levonorgestrel Intrauterine Device After Vaginal Delivery

    PubMed Central

    Chen, Beatrice A.; Reeves, Matthew F.; Hayes, Jennifer L.; Hohmann, Heather L.; Perriera, Lisa K.; Creinin, Mitchell D.

    2011-01-01

    OBJECTIVE To estimate whether 6-month use of the levonorgestrel-releasing intrauterine device (IUD) would be higher when insertion occurred within 10 minutes of placental delivery compared with 6–8 weeks postpartum. METHODS We enrolled pregnant women planning vaginal deliveries and desiring a postpartum levonorgestrel-releasing IUD. Patients were randomly assigned when admitted in labor to postplacental or delayed IUD insertion. The women followed up in person at 6–8 weeks and 6 months and were contacted by telephone at 3 months. Women were ineligible for a study IUD postenrollment for intrapartum events including infection, hemorrhage, and cesarean delivery; these women were contacted by phone at 3 and 6 months. Expelled IUDs were replaced per patient preference. RESULTS Successful IUD placement occurred in 50 of 51 participants (98.0%) and 46 of 51 participants (90.2%) in the postplacental and delayed groups, respectively (P=.2). Expulsion within 6 months occurred in 12 of 50 (24.0%; 95% confidence interval [CI], 13.1–38.2) and two of 46 (4.4%; 95% CI 0.5–14.8) participants, respectively (P=.008). Intrauterine device use at 6 months was 43 of 51 (84.3%; 95% CI 71.4–93.0) and 39 of 51 (76.5%; 95% CI 62.5–87.2), respectively (P=.32). For ineligible patients, only 11 of 41 (26.8%) women were using IUDs at 6 months and two (4.9%) had become pregnant. CONCLUSION Intrauterine device use 6 months after delivery is similar in women who have postpartum or scheduled delayed IUD placement through a study after replacement of expelled IUDs. Expulsions are significantly higher with postplacental compared with delayed IUD placement. Women asked to follow up with their own health care providers for delayed insertion are significantly less likely to receive an IUD. CLINICALTRIALREGISTRATION ClinicalTrials.gov, www.clinicaltrials.gov, NCT00476021. LEVEL OF EVIDENCE I PMID:20966692

  6. Microfluidic Actuation of Carbon Nanotube Fibers for Neural Recordings

    NASA Astrophysics Data System (ADS)

    Vercosa, Daniel G.

    Implantable devices to record and stimulate neural circuits have led to breakthroughs in neuroscience; however, technologies capable of electrical recording at the cellular level typically rely on rigid metals that poorly match the mechanical properties of soft brain tissue. As a result these electrodes often cause extensive acute and chronic injury, leading to short electrode lifetime. Recently, flexible electrodes such as Carbon Nanotube fibers (CNTf) have emerged as an attractive alternative to conventional electrodes and studies have shown that these flexible electrodes reduce neuro-inflammation and increase the quality and longevity of neural recordings. Insertion of these new compliant electrodes, however, remains challenge. The stiffening agents necessary to make the electrodes rigid enough to be inserted increases device footprint, which exacerbates brain damage during implantation. To overcome this challenge we have developed a novel technology to precisely implant and actuate high-performance, flexible carbon nanotube fiber (CNTf) microelectrodes without using a stiffening agents or shuttles. Instead, our technology uses drag forces within a microfluidic device to drive electrodes into tissue while minimizing the amount of fluid that is ejected into the tissue. In vitro experiments in brain phantoms, show that microfluidic actuated CNTf can be implanted at least 4.5 mm depth with 30 microm precision, while keeping the total volume of fluid ejected below 0.1 microL. As proof of concept, we inserted CNTfs in the small cnidarian Hydra littoralis and observed compound action potentials corresponding to contractions and in agreement with the literature. Additionally, brain slices extracted from transgenic mice were used to show that our device can be used to record spontaneous and light evoked activity from the cortex and deep brain regions such as the thalamic reticular nucleus (TRN). Overall our microfluidic actuation technology provides a platform for implanting and actuating flexible electrodes that significantly reduces damage during insertion.

  7. Does a 4 diagram manual enable laypersons to operate the Laryngeal Mask Supreme®? A pilot study in the manikin.

    PubMed

    Schälte, Gereon; Stoppe, Christian; Rossaint, Rolf; Gilles, Laura; Heuser, Maike; Rex, Steffen; Coburn, Mark; Zoremba, Norbert; Rieg, Annette

    2012-03-27

    Bystander resuscitation plays an important role in lifesaving cardiopulmonary resuscitation (CPR). A significant reduction in the "no-flow-time", quantitatively better chest compressions and an improved quality of ventilation can be demonstrated during CPR using supraglottic airway devices (SADs). Previous studies have demonstrated the ability of inexperienced persons to operate SADs after brief instruction. The aim of this pilot study was to determine whether an instruction manual consisting of four diagrams enables laypersons to operate a Laryngeal Mask Supreme® (LMAS) in the manikin. An instruction manual of four illustrations with speech bubbles displaying the correct use of the LMAS was designed. Laypersons were handed a bag containing a LMAS, a bag mask valve device (BMV), a syringe prefilled with air and the instruction sheet, and were asked to perform and ventilate the manikin as displayed. Time to ventilation was recorded and degree of success evaluated. A total of 150 laypersons took part. Overall 145 participants (96.7%) inserted the LMAS in the manikin in the right direction. The device was inserted inverted or twisted in 13 (8.7%) attempts. Eight (5.3%) individuals recognized this and corrected the position. Within the first 2 minutes 119 (79.3%) applicants were able to insert the LMAS and provide tidal volumes greater than 150 ml (estimated dead space). Time to insertion and first ventilation was 83.2 ± 29 s. No significant difference related to previous BLS training (P = 0.85), technical education (P = 0.07) or gender could be demonstrated (P = 0.25). In manikin laypersons could insert LMAS in the correct direction after onsite instruction by a simple manual with a high success rate. This indicates some basic procedural understanding and intellectual transfer in principle. Operating errors (n = 91) were frequently not recognized and corrected (n = 77). Improvements in labeling and the quality of instructional photographs may reduce individual error and may optimize understanding.

  8. Development of Multi-Functional Voltage Restore System

    NASA Astrophysics Data System (ADS)

    Suzuki, Satoshi; Ueda, Yoshinobu; Koganezawa, Takehisa; Ogihara, Yoshinori; Mori, Kenjiro; Fukazu, Naoaki

    Recently, with the dawn of the electric deregulation, the installation of distributed generation with power electronics device has grown. This current causes a greater concern of power quality, primarily voltage disturbance for power companies, and their interest in power quality is peaking. Utilities are also interested in keeping their customers satisfied, as well as keeping them on-line and creating more revenue for the utility. As a countermeasure against the above surroundings, a variety type of devices based on power electronics has been developed to protect customers' load from power line voltage disturbance. One of them is the series type voltage restore. The series device is an active device, designed to provide a pure sinusoidal load voltage at all times, correcting voltage disturbance. Series type device compensates for voltage anomalies by inserting the ‘missing’ voltage onto the line through insertion transformer and inverter. This paper shows the setting guideline of target level to compensate voltage disturbance, that is, voltage dip, voltage harmonics, voltage imbalance and voltage flicker, and the design approach of the prototype of series voltage restores to accomplish the required compensation level. The prototype system gives satisfactory compensation performance through evaluation tests, which confirm the validity and effectiveness of the system.

  9. Cermet insert high voltage holdoff improvement for ceramic/metal vacuum devices

    DOEpatents

    Ierna, W.F.

    1986-03-11

    An improved metal-to-ceramic seal is provided wherein the ceramic body of the seal contains an integral region of cermet material in electrical contact with the metallic member, e.g., an electrode, of the seal. The seal is useful in high voltage vacuum devices, e.g., vacuum switches, and increases the high-voltage holdoff capabilities of such devices. A method of fabricating such seals is also provided.

  10. Cermet insert high voltage holdoff for ceramic/metal vacuum devices

    DOEpatents

    Ierna, William F.

    1987-01-01

    An improved metal-to-ceramic seal is provided wherein the ceramic body of the seal contains an integral region of cermet material in electrical contact with the metallic member, e.g., an electrode, of the seal. The seal is useful in high voltage vacuum devices, e.g., vacuum switches, and increases the high-voltage holdoff capabilities of such devices. A method of fabricating such seals is also provided.

  11. Raney nickel catalytic device

    DOEpatents

    O'Hare, Stephen A.

    1978-01-01

    A catalytic device for use in a conventional coal gasification process which includes a tubular substrate having secured to its inside surface by expansion a catalytic material. The catalytic device is made by inserting a tubular catalytic element, such as a tubular element of a nickel-aluminum alloy, into a tubular substrate and heat-treating the resulting composite to cause the tubular catalytic element to irreversibly expand against the inside surface of the substrate.

  12. [Inserts for foot deformities].

    PubMed

    Stinus, H; Weber, F

    2005-08-01

    Inserts are orthopedic aids in the treatment of foot disorders that result from changes of the static or dynamic situation. Provision of appropriate orthopedic devices can relieve the pain caused by forefoot deformities either in lieu of surgical intervention or in rare cases also following surgical treatment to improve the symptoms of residual pain.Available materials provide support, padding, and cushioning. Inserts are custom-made to measure and/or based on a plaster impression. Determining the indication, prescribing the inlay, and checking the orthosis are the tasks of the physician. One treatment option for relieving the pain of forefoot deformities consists in conservative therapy with an insert combining features of padding and support as well as adjusting a ready-made shoe. The shoe and inlay should constitute a functional unit since often the optimal effect is only achieved with a combination of insert and orthopedic adjustment of the ready-made shoe.

  13. Experimental Verification of Modeled Thermal Distribution Produced by a Piston Source in Physiotherapy Ultrasound

    PubMed Central

    Lopez-Haro, S. A.; Leija, L.

    2016-01-01

    Objectives. To present a quantitative comparison of thermal patterns produced by the piston-in-a-baffle approach with those generated by a physiotherapy ultrasonic device and to show the dependency among thermal patterns and acoustic intensity distributions. Methods. The finite element (FE) method was used to model an ideal acoustic field and the produced thermal pattern to be compared with the experimental acoustic and temperature distributions produced by a real ultrasonic applicator. A thermal model using the measured acoustic profile as input is also presented for comparison. Temperature measurements were carried out with thermocouples inserted in muscle phantom. The insertion place of thermocouples was monitored with ultrasound imaging. Results. Modeled and measured thermal profiles were compared within the first 10 cm of depth. The ideal acoustic field did not adequately represent the measured field having different temperature profiles (errors 10% to 20%). Experimental field was concentrated near the transducer producing a region with higher temperatures, while the modeled ideal temperature was linearly distributed along the depth. The error was reduced to 7% when introducing the measured acoustic field as the input variable in the FE temperature modeling. Conclusions. Temperature distributions are strongly related to the acoustic field distributions. PMID:27999801

  14. Specifiers Properties Information Exchange (SPie): Minimum Building Information Model (BIM) Object Definitions

    DTIC Science & Technology

    2013-03-01

    Weave Welding Method Wheel Assembly Wind Load Wind Loads Wind Uplift Resistance Wind Uplift Resistance Class Window Category Window Finish Window... wind - blast Elongation UFGS 2.1 percent Insert Value Visual Defects UFGS 2.1 n/a Insert Value ERDC/CERL CR-13-1 39 Attribute Source...Sustainability COBie Guide n/a insert reqts FRP Strengthening UFGS 1.2 n/a seismic - wind - blast Elongation UFGS 2.2 percent Insert Value Tensile

  15. The effect of esophagogastroduodenoscopy probe insertion on the intracuff pressure of airway devices in children during general anesthesia.

    PubMed

    Balaban, Onur; Kamata, Mineto; Hakim, Mumin; Tumin, Dmitry; Tobias, Joseph D

    2017-04-01

    Given the size of the esophagogastroduodenoscopy (EGD) probe and the compressibility of the pediatric airway, the EGD probe may increase the intracuff pressure (IP) of an airway device. The current study evaluated IP changes during EGD examination under general anesthesia in pediatric patients. Following the induction of anesthesia, a laryngeal mask airway (LMA) or endotracheal tube (ETT) was placed without neuromuscular blockade. The IP was measured at baseline, during EGD probe insertion, while the EGD probe was in place, and after probe removal. The study cohort included 101 patients (mean age 11.3 years). The airway was secured with an LMA and an ETT in 88 and 13 patients, respectively. The IP increased from 27 ± 15 cmH 2 O at baseline to 34 ± 17 cmH 2 O during probe insertion (p < 0.001), remained at 33 ± 16 cmH 2 O while the probe was in place, and decreased to 26 ± 14 cmH 2 O after probe removal. The IP of the LMA or ETT increased during EGD probe insertion and remained elevated while the probe was in place. High IP may compromise mucosal perfusion resulting in a sore throat when using an LMA or the potential for airway damage if an ETT is used. Removal of air from the cuff and titration of the IP should be considered after EGD insertion.

  16. Left ventricular diastolic filling with an implantable ventricular assist device: beat to beat variability with overall improvement

    NASA Technical Reports Server (NTRS)

    Nakatani, S.; Thomas, J. D.; Vandervoort, P. M.; Zhou, J.; Greenberg, N. L.; Savage, R. M.; McCarthy, P. M.

    1997-01-01

    OBJECTIVES: We studied the effects of left ventricular (LV) unloading by an implantable ventricular assist device on LV diastolic filling. BACKGROUND: Although many investigators have reported reliable systemic and peripheral circulatory support with implantable LV assist devices, little is known about their effect on cardiac performance. METHODS: Peak velocities of early diastolic filling, late diastolic filling, late to early filling ratio, deceleration time of early filling, diastolic filling period and atrial filling fraction were measured by intraoperative transesophageal Doppler echocardiography before and after insertion of an LV assist device in eight patients. A numerical model was developed to simulate this situation. RESULTS: Before device insertion, all patients showed either a restrictive or a monophasic transmitral flow pattern. After device insertion, transmitral flow showed rapid beat to beat variation in each patient, from abnormal relaxation to restrictive patterns. However, when the average values obtained from 10 consecutive beats were considered, overall filling was significantly normalized from baseline, with early filling velocity falling from 87 +/- 31 to 64 +/- 26 cm/s (p < 0.01) and late filling velocity rising from 8 +/- 11 to 32 +/- 23 cm/s (p < 0.05), resulting in an increase in the late to early filling ratio from 0.13 +/- 0.18 to 0.59 +/- 0.38 (p < 0.01) and a rise in the atrial filling fraction from 8 +/- 10% to 26 +/- 17% (p < 0.01). The deceleration time (from 112 +/- 40 to 160 +/- 44 ms, p < 0.05) and the filling period corrected by the RR interval (from 39 +/- 8% to 54 +/- 10%, p < 0.005) were also significantly prolonged. In the computer model, asynchronous LV assistance produced significant beat to beat variation in filling indexes, but overall a normalization of deceleration time as well as other variables. CONCLUSIONS: With LV assistance, transmitral flow showed rapidly varying patterns beat by beat in each patient, but overall diastolic filling tended to normalize with an increase of atrial contribution to the filling. Because of the variable nature of the transmitral flow pattern with the assist device, the timing of the device cycle must be considered when inferring diastolic function from transmitral flow pattern.

  17. Coded excitation ultrasonic needle tracking: An in vivo study.

    PubMed

    Xia, Wenfeng; Ginsberg, Yuval; West, Simeon J; Nikitichev, Daniil I; Ourselin, Sebastien; David, Anna L; Desjardins, Adrien E

    2016-07-01

    Accurate and efficient guidance of medical devices to procedural targets lies at the heart of interventional procedures. Ultrasound imaging is commonly used for device guidance, but determining the location of the device tip can be challenging. Various methods have been proposed to track medical devices during ultrasound-guided procedures, but widespread clinical adoption has remained elusive. With ultrasonic tracking, the location of a medical device is determined by ultrasonic communication between the ultrasound imaging probe and a transducer integrated into the medical device. The signal-to-noise ratio (SNR) of the transducer data is an important determinant of the depth in tissue at which tracking can be performed. In this paper, the authors present a new generation of ultrasonic tracking in which coded excitation is used to improve the SNR without spatial averaging. A fiber optic hydrophone was integrated into the cannula of a 20 gauge insertion needle. This transducer received transmissions from the ultrasound imaging probe, and the data were processed to obtain a tracking image of the needle tip. Excitation using Barker or Golay codes was performed to improve the SNR, and conventional bipolar excitation was performed for comparison. The performance of the coded excitation ultrasonic tracking system was evaluated in an in vivo ovine model with insertions to the brachial plexus and the uterine cavity. Coded excitation significantly increased the SNRs of the tracking images, as compared with bipolar excitation. During an insertion to the brachial plexus, the SNR was increased by factors of 3.5 for Barker coding and 7.1 for Golay coding. During insertions into the uterine cavity, these factors ranged from 2.9 to 4.2 for Barker coding and 5.4 to 8.5 for Golay coding. The maximum SNR was 670, which was obtained with Golay coding during needle withdrawal from the brachial plexus. Range sidelobe artifacts were observed in tracking images obtained with Barker coded excitation, and they were visually absent with Golay coded excitation. The spatial tracking accuracy was unaffected by coded excitation. Coded excitation is a viable method for improving the SNR in ultrasonic tracking without compromising spatial accuracy. This method provided SNR increases that are consistent with theoretical expectations, even in the presence of physiological motion. With the ultrasonic tracking system in this study, the SNR increases will have direct clinical implications in a broad range of interventional procedures by improving visibility of medical devices at large depths.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berland, Brian Spencer; Lanning, Bruce Roy; Stowell, Jr., Michael Wayne

    This disclosure describes system and methods for creating an autonomous electrochromic assembly, and systems and methods for use of the autonomous electrochromic assembly in combination with a window. Embodiments described herein include an electrochromic assembly that has an electrochromic device, an energy storage device, an energy collection device, and an electrochromic controller device. These devices may be combined into a unitary electrochromic insert assembly. The electrochromic assembly may have the capability of generating power sufficient to operate and control an electrochromic device. This control may occur through the application of a voltage to an electrochromic device to change its opacitymore » state. The electrochromic assembly may be used in combination with a window.« less

  19. 78 FR 66942 - Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-07

    ...., polyetheretherketone) materials. They are intended to be inserted between the vertebral bodies into the disc space from... mobility in confined spaces, at an elevated height, climb curbs, ascend/descend stairs, traverse obstacles, travel over a wider variety of terrain, and negotiate uneven/inclined surfaces. Stair-climbing...

  20. Mid-infrared refractive index sensing using optimized slotted photonic crystal waveguides

    NASA Astrophysics Data System (ADS)

    Kassa-Baghdouche, Lazhar; Cassan, Eric

    2018-02-01

    Slotted photonic crystal waveguides (SPCWs) were designed to act as refractive index sensing devices at mid-infrared (IR) wavelengths around λ = 3.6 μm. In particular, effort was made to engineer the input and output slot waveguide interfaces in order to increase the effective sensitivity through resonant tapering. A slotted PhC waveguide immersed in air and liquid cladding layers was considered. To determine the performance of the sensor, the sensitivity of the device was estimated by calculating the shift in the upper band edge of the output transmission spectrum. The results showed that the sensitivity of a conventionally designed SPCW followed by modifications in the structure parameter yielded a 510 nm shift in the wavelength position of the upper band edge, indicating a sensitivity of more than 1150 nm per refractive index unit (RIU) with an insertion loss level of -0.3 dB. This work demonstrates the viability of photonic crystal waveguide high sensitivity devices in the Mid-IR, following a transposition of the concepts inherited from the telecom band and an optimization of the design, in particular a minimization of photonic device insertion losses.

  1. Substantial harm associated with failure of chronic paediatric central venous access devices.

    PubMed

    Ullman, Amanda J; Kleidon, Tricia; Cooke, Marie; Rickard, Claire M

    2017-07-06

    Central venous access devices (CVADs) form an important component of modern paediatric healthcare, especially for children with chronic health conditions such as cancer or gastrointestinal disorders. However device failure and complications rates are high.Over 2½ years, a child requiring parenteral nutrition and associated vascular access dependency due to 'short gut syndrome' (intestinal failure secondary to gastroschisis and resultant significant bowel resection) had ten CVADs inserted, with ninesubsequently failing. This resulted in multiple anaesthetics, invasive procedures, injuries, vascular depletion, interrupted nutrition, delayed treatment and substantial healthcare costs. A conservative estimate of the institutional costs for each insertion, or rewiring, of her tunnelled CVAD was $A10 253 (2016 Australian dollars).These complications and device failures had significant negative impact on the child and her family. Considering the commonality of conditions requiring prolonged vascular access, these failures also have a significant impact on international health service costs. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Integrated Microbatteries for Implantable Medical Devices

    NASA Technical Reports Server (NTRS)

    Whitacre, Jay; West, William

    2008-01-01

    Integrated microbatteries have been proposed to satisfy an anticipated need for long-life, low-rate primary batteries, having volumes less than 1 mm3, to power electronic circuitry in implantable medical devices. In one contemplated application, such a battery would be incorporated into a tubular hearing-aid device to be installed against an eardrum. This device is based on existing tube structures that have already been approved by the FDA for use in human ears. As shown in the figure, the battery would comprise a single cell at one end of the implantable tube. A small volume of Li-based primary battery cathode material would be compacted and inserted in the tube near one end, followed by a thin porous separator, followed by a pressed powder of a Li-containing alloy. Current-collecting wires would be inserted, with suitably positioned insulators to prevent a short circuit. The battery would contain a liquid electrolyte consisting of a Li-based salt in an appropriate solvent. Hermetic seals would be created by plugging both ends with a waterproof polymer followed by deposition of parylene.

  3. A biplanar fluoroscopic approach for the measurement, modeling, and simulation of needle and soft-tissue interaction.

    PubMed

    Hing, James T; Brooks, Ari D; Desai, Jaydev P

    2007-02-01

    A methodology for modeling the needle and soft-tissue interaction during needle insertion is presented. The approach consists of the measurement of needle and tissue motion using a dual C-arm fluoroscopy system. Our dual C-arm fluoroscopy setup allows real time 3-D extraction of the displacement of implanted fiducials in the soft tissue during needle insertion to obtain the necessary parameters for accurate modeling of needle and soft-tissue interactions. The needle and implanted markers in the tissue are tracked during the insertion and withdrawal of the needle at speeds of 1.016 mm/s, 12.7 mm/s and 25.4 mm/s. Both image and force data are utilized to determine important parameters such as the approximate cutting force, puncture force, the local effective modulus (LEM) during puncture, and the relaxation of tissue. We have also validated the LEM computed from our finite element model with arbitrary needle puncture tasks. Based on these measurements, we developed a model for needle insertion and withdrawal that can be used to generate a 1-DOF force versus position profile that can be experienced by a user operating a haptic device. This profile was implemented on a 7-DOf haptic device designed in our laboratory.

  4. Atomistic Conversion Reaction Mechanism of WO 3 in Secondary Ion Batteries of Li, Na, and Ca

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    He, Yang; Gu, Meng; Xiao, Haiyan

    2016-04-13

    Reversible insertion and extraction of ionic species into a host lattice governs the basic operating principle for both rechargeable battery (such as lithium batteries) and electrochromic devices (such as ANA Boeing 787-8 Dreamliner electrochromic window). Intercalation and/or conversion are two fundamental chemical processes for some materials in response to the ion insertion. The interplay between these two chemical processes has never been established. It is speculated that the conversion reaction is initiated by ion intercalation. However, experimental evidence of intercalation and subsequent conversion remains unexplored. Here, using in situ HRTEM and spectroscopy, we captured the atomistic conversion reaction processes duringmore » lithium, sodium and calcium ion insertion into tungsten trioxide (WO3) single crystal model electrodes. An intercalation step right prior to conversion is explicitly revealed at atomic scale for the first time for these three ion species. Combining nanoscale diffraction and ab initio molecular dynamics simulations, it is found that, beyond intercalation, the inserted ion-oxygen bonding formation destabilized the transition-metal framework which gradually shrunk, distorted and finally collapsed to a pseudo-amorphous structure. This study provides a full atomistic picture on the transition from intercalation to conversion, which is of essential for material applications in both secondary ion batteries and electrochromic devices.« less

  5. [Impact of intrauterine device insertion surgery on women's mental state].

    PubMed

    Chu, Guang-hua; Zou, Yan; Wang, Xiao-ye; Li, Su-xia; Huang, Zi-rong; Fang, Ai-hua; Tian, Ai-ping

    2013-06-01

    To evaluate the impact of the intrauterine device (IUD) insertion on the mental state of women. From Jan. 2009 to Jun. 2010, a multi-center clinical observational study was performed. Totally 641 women were selected in the six provinces' 18 family planning service stations and hospitals for IUD insertion surgery study. Analysis of the change of women's mental state which was evaluated by symptom checklist-90 (SCL-90) scale before and after IUD insertion surgery. Before and after IUD insertion surgery, 10 factors' scores in SCL-90 of the observed objects were between 1.1 to 1.2, total scores were 107±27 and 105±25, respectively. Before and after surgery, total average score both were 1.2, the average score of positive items both were 2.1. The difference of the above results were not statistically significance (all P>0.05). Preoperative and postoperative, the rate of positive items was 9.2%-19.6% and 7.7%-17.6%, respectively.In addition to anxiety and fear, the rate of other factors' positive items postoperative was significantly lower than those in the preoperative (all P<0.05). The incidence of the observed objects postoperative of each factor score, "deteriorated" was in the range of 4.9% to 23.0%, "improved" was in the range of 26.3%-50.1%. The incidence of total scores, "deterioration" was 28.8% (166/575), "improved" was 45.6% (262/575). The incidence of the average score of positive items, "deterioration" was 3.7% (21/575), "improved" was 52.3% (301/575). Logistic analysis showed that, in addition to unit level, there were no other significant influencing factors for women' mental state of postoperative (all P>0.05). IUD insertion surgery has no adverse effect on women's mental state.

  6. A closed-loop photon beam control study for the Advanced Light Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Portmann, G.; Bengtsson, J.

    1993-05-01

    The third generation Advanced Light Source (ALS) will produce extremely bright photon beams using undulators and wigglers. In order to position the photon beams accurate to the micron level, a closed-loop feedback system is being developed. Using photon position monitors and dipole corrector magnets, a closed-loop system can automatically compensate for modeling uncertainties and exogenous disturbances. The following paper will present a dynamics model for the perturbations of the closed orbit of the electron beam in the ALS storage ring including the vacuum chamber magnetic field penetration effects. Using this reference model, two closed-loop feedback algorithms will be compared --more » a classical PI controller and a two degree-of-freedom approach. The two degree-of-freedom method provides superior disturbance rejection while maintaining the desired performance goals. Both methods will address the need to gain schedule the controller due to the time varying dynamics introduced by changing field strengths when scanning the insertion devices.« less

  7. The SpikerBox: A Low Cost, Open-Source BioAmplifier for Increasing Public Participation in Neuroscience Inquiry

    PubMed Central

    Marzullo, Timothy C.; Gage, Gregory J.

    2012-01-01

    Although people are generally interested in how the brain functions, neuroscience education for the public is hampered by a lack of low cost and engaging teaching materials. To address this, we developed an open-source tool, the SpikerBox, which is appropriate for use in middle/high school educational programs and by amateurs. This device can be used in easy experiments in which students insert sewing pins into the leg of a cockroach, or other invertebrate, to amplify and listen to the electrical activity of neurons. With the cockroach leg preparation, students can hear and see (using a smartphone oscilloscope app we have developed) the dramatic changes in activity caused by touching the mechanosensitive barbs. Students can also experiment with other manipulations such as temperature, drugs, and microstimulation that affect the neural activity. We include teaching guides and other resources in the supplemental materials. These hands-on lessons with the SpikerBox have proven to be effective in teaching basic neuroscience. PMID:22470415

  8. Enhanced heat transfer and frictional losses in heat exchanger tube with modified helical coiled inserts

    NASA Astrophysics Data System (ADS)

    Verma, Aditya; Kumar, Manoj; Patil, Anil Kumar

    2018-04-01

    The application of compact heat exchangers in any thermal system improves overall performance with a considerable reduction in size and weight. Inserts of different geometrical features have been used as turbulence promoting devices to increase the heat transfer rates. The present study deals with the experimental investigation of heat transfer and fluid flow characteristics of a tubular heat exchanger fitted with modified helical coiled inserts. Experiments have been carried out for a smooth tube without insert, tube fitted with helical coiled inserts, and modified helical coiled inserts. The helical coiled inserts are tested by varying the pitch ratio and wire diameter ratio from 0.5-1.5, and 0.063-0.125, respectively for the Reynolds number range of 1400 to 11,000. Experimental data have also been collected for the modified helical coiled inserts with gradually increasing pitch (GIP) and gradually decreasing pitch (GDP) configurations. The Nusselt number and friction factor values for helical coiled inserts are enhanced in the range of 1.42-2.62, 3.4-27.4, relative to smooth tube, respectively. The modified helical coiled insert showed enhancements in Nusselt number and friction factor values in the range of 1.49-3.14, 11.2-19.9, relative to smooth tube, respectively. The helical coiled and modified helical coiled inserts have thermo-hydraulic performance factor in the range of 0.59-1.29, 0.6-1.39, respectively. The empirical correlations of Nusselt number and friction factor for helical coiled inserts are proposed.

  9. Mucoadhesive ocular insert based on thiolated poly(acrylic acid): development and in vivo evaluation in humans.

    PubMed

    Hornof, Margit; Weyenberg, Wim; Ludwig, Annick; Bernkop-Schnürch, Andreas

    2003-05-20

    The aim of the study was to develop a mucoadhesive ocular insert for the controlled delivery of ophthalmic drugs and to evaluate its efficacy in vivo. The inserts tested were based either on unmodified or thiolated poly(acrylic acid). Water uptake and swelling behavior of the inserts as well as the drug release rates of the model drugs fluorescein and two diclofenac salts with different solubility properties were evaluated in vitro. Fluorescein was used as fluorescent tracer to study the drug release from the insert in humans. The mean fluorescein concentration in the cornea/tearfilm compartment as a function of time was determined after application of aqueous eye drops and inserts composed of unmodified and of thiolated poly(acrylic acid). The acceptability of the inserts by the volunteers was also evaluated. Inserts based on thiolated poly(acrylic acid) were not soluble and had good cohesive properties. A controlled release was achieved for the incorporated model drugs. The in vivo study showed that inserts based on thiolated poly(acrylic acid) provide a fluorescein concentration on the eye surface for more than 8 h, whereas the fluorescein concentration rapidly decreased after application of aqueous eye drops or inserts based on unmodified poly(acrylic acid). Moreover, these inserts were well accepted by the volunteers. The present study indicates that ocular inserts based on thiolated poly(acrylic acid) are promising new solid devices for ocular drug delivery.

  10. NATIONAL SYNCHROTRON LIGHT SOURCE ACTIVITY REPORT 1998.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ROTHMAN,E.

    1999-05-01

    In FY 1998, following the 50th Anniversary Year of Brookhaven National Laboratory, Brookhaven Science Associates became the new Managers of BNL. The new start is an appropriate time to take stock of past achievements and to renew or confirm future goals. During the 1998 NSLS Annual Users Meeting (described in Part 3 of this Activity Report), the DOE Laboratory Operations Board, Chaired by the Under Secretary for Energy, Ernest Moniz met at BNL. By chance all the NSLS Chairmen except Martin Blume (acting NSLS Chair 84-85) were present as recorded in the picture. Under their leadership the NSLS has improvedmore » dramatically: (1) The VUV Ring current has increased from 100 mA in October 1982 to nearly 1 A today. For the following few years 10 Ahrs of current were delivered most weeks - NSLS now exceeds that every day. (2) When the first experiments were performed on the X-ray ring during FY1985 the electron energy was 2 GeV and the current up to 100 mA - the X-Ray Ring now runs routinely at 2.5 GeV and at 2.8 GeV with up to 350 mA of current, with a very much longer beam half-life and improved reliability. (3) Starting in FY 1984 the proposal for the Phase II upgrade, mainly for a building extension and a suite of insertion devices and their associated beamlines, was pursued - the promises were delivered in full so that for some years now the NSLS has been running with two undulators in the VUV Ring and three wigglers and an undulator in the X-Ray Ring. In addition two novel insertion devices have been commissioned in the X13 straight. (4) At the start of FY 1998 the NSLS welcomed its 7000th user - attracted by the opportunity for pursuing research with high quality beams, guaranteed not to be interrupted by 'delivery failures', and welcomed by an efficient and caring user office and first class teams of PRT and NSLS staff. R & D have lead to the possibility of running the X-Ray Ring at the higher energy of 2.8 GeV. Figure 1 shows the first user beam, which was provided thereafter for half of the running time in FY 1998. In combination with the development of narrow gap undulators this mode opens the possibility of new undulators which could produce hard X-rays in the fundamental, perhaps up to 10 keV. On 27 September 1998, a low horizontal emittance lattice became operational at 2.584 GeV. This results in approximately a 50% decrease in the horizontal beam-size on dipole bending magnet beamlines, and somewhat less of a decrease on the insertion device lines. The beam lifetime is not degraded by the low emittance lattice. This represents an important achievement, enhancing for all users the x-ray ring brightness. The reduced horizontal emittance electron beam will produce brighter x-ray beams for all the beamlines, both bending magnets and insertion devices, adding to other recent increases in the X-Ray ring brightness. During FY 1999 users will gain experience of the new running mode and plans are in place to do the same at 2.8GeV during further studies sessions. Independent evidence of the reduced emittance is shown in Figure 2. This is a pinhole camera scan showing the X-ray beam profile, obtained on the diagnostic beamline X28. Finally, work has begun to update and refine the proposal of the Phase III upgrade endorsed by the Birgeneau panel and BESAC last year. With the whole NSLS facility in teenage years and with many demonstrated enhancements available, the time has come to herald in the next stage of life at the Light Source.« less

  11. An update on carbon nanotube-enabled X-ray sources for biomedical imaging.

    PubMed

    Puett, Connor; Inscoe, Christina; Hartman, Allison; Calliste, Jabari; Franceschi, Dora K; Lu, Jianping; Zhou, Otto; Lee, Yueh Z

    2018-01-01

    A new imaging technology has emerged that uses carbon nanotubes (CNT) as the electron emitter (cathode) for the X-ray tube. Since the performance of the CNT cathode is controlled by simple voltage manipulation, CNT-enabled X-ray sources are ideal for the repetitive imaging steps needed to capture three-dimensional information. As such, they have allowed the development of a gated micro-computed tomography (CT) scanner for small animal research as well as stationary tomosynthesis, an experimental technology for large field-of-view human imaging. The small animal CT can acquire images at specific points in the respiratory and cardiac cycles. Longitudinal imaging therefore becomes possible and has been applied to many research questions, ranging from tumor response to the noninvasive assessment of cardiac output. Digital tomosynthesis (DT) is a low-dose and low-cost human imaging tool that captures some depth information. Known as three-dimensional mammography, DT is now used clinically for breast imaging. However, the resolution of currently-approved DT is limited by the need to swing the X-ray source through space to collect a series of projection views. An array of fixed and distributed CNT-enabled sources provides the solution and has been used to construct stationary DT devices for breast, lung, and dental imaging. To date, over 100 patients have been imaged on Institutional Review Board-approved study protocols. Early experience is promising, showing an excellent conspicuity of soft-tissue features, while also highlighting technical and post-acquisition processing limitations that are guiding continued research and development. Additionally, CNT-enabled sources are being tested in miniature X-ray tubes that are capable of generating adequate photon energies and tube currents for clinical imaging. Although there are many potential applications for these small field-of-view devices, initial experience has been with an X-ray source that can be inserted into the mouth for dental imaging. Conceived less than 20 years ago, CNT-enabled X-ray sources are now being manufactured on a commercial scale and are powering both research tools and experimental human imaging devices. WIREs Nanomed Nanobiotechnol 2018, 10:e1475. doi: 10.1002/wnan.1475 This article is categorized under: Diagnostic Tools > Diagnostic Nanodevices Diagnostic Tools > In Vivo Nanodiagnostics and Imaging. © 2017 Wiley Periodicals, Inc.

  12. Characterisation of protein stability in rod-insert vaginal rings.

    PubMed

    Pattani, Aditya; Lowry, Deborah; Curran, Rhonda M; McGrath, Stephanie; Kett, Vicky L; Andrews, Gavin P; Malcolm, R Karl

    2012-07-01

    A major goal in vaccine development is elimination of the 'cold chain', the transport and storage system for maintenance and distribution of the vaccine product. This is particularly pertinent to liquid formulation of vaccines. We have previously described the rod-insert vaginal ring (RiR) device, comprising an elastomeric body into which are inserted lyophilised, rod-shaped, solid drug dosage forms, and having potential for sustained mucosal delivery of biomacromolecules, such as HIV envelope protein-based vaccine candidates. Given the solid, lyophilised nature of these insert dosage forms, we hypothesised that antigen stability may be significantly increased compared with more conventional solubilised vaginal gel format. In this study, we prepared and tested vaginal ring devices fitted with lyophilised rod inserts containing the model antigen bovine serum albumin (BSA). Both the RiRs and the gels that were freeze-dried to prepare the inserts were evaluated for BSA stability using PAGE, turbidimetry, microbial load, MALDI-TOF and qualitative precipitate solubility measurements. When stored at 4 °C, but not when stored at 40 °C/75% RH, the RiR formulation offered protection against structural and conformational changes to BSA. The insert also retained matrix integrity and release characteristics. The results demonstrate that lypophilised gels can provide relative protection against degradation at lower temperatures compared to semi-solid gels. The major mechanism of degradation at 40 °C/75% RH was shown to be protein aggregation. Finally, in a preliminary study, we found that addition of trehalose to the formulation significantly reduces the rate of BSA degradation compared to the original formulation when stored at 40 °C/75% RH. Establishing the mechanism of degradation, and finding that degradation is decelerated in the presence of trehalose, will help inform further development of RiRs specifically and polymer based freeze-dried systems in general. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Single-drop optimization of protein crystallization.

    PubMed

    Meyer, Arne; Dierks, Karsten; Hilterhaus, Dierk; Klupsch, Thomas; Mühlig, Peter; Kleesiek, Jens; Schöpflin, Robert; Einspahr, Howard; Hilgenfeld, Rolf; Betzel, Christian

    2012-08-01

    A completely new crystal-growth device has been developed that permits charting a course across the phase diagram to produce crystalline samples optimized for diffraction experiments. The utility of the device is demonstrated for the production of crystals for the traditional X-ray diffraction data-collection experiment, of microcrystals optimal for data-collection experiments at a modern microbeam insertion-device synchrotron beamline and of nanocrystals required for data collection on an X-ray laser beamline.

  14. Suppressing recombination in polymer photovoltaic devices via energy-level cascades.

    PubMed

    Tan, Zhi-Kuang; Johnson, Kerr; Vaynzof, Yana; Bakulin, Artem A; Chua, Lay-Lay; Ho, Peter K H; Friend, Richard H

    2013-08-14

    An energy cascading structure is designed in a polymer photovoltaic device to suppress recombination and improve quantum yields. By the insertion of a thin polymer interlayer with intermediate energy levels, electrons and holes can effectively shuttle away from each other while being spatially separated from recombination. An increase in open-circuit voltage and short-circuit current are observed in modified devices. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Ultrasound Improves Cricothyrotomy Success in Cadavers with Poorly Defined Neck Anatomy: A Randomized Control Trial.

    PubMed

    Siddiqui, Naveed; Arzola, Cristian; Friedman, Zeev; Guerina, Laarni; You-Ten, Kong Eric

    2015-11-01

    Misidentification of the cricothyroid membrane in a "cannot intubate-cannot oxygenate" situation can lead to failures and serious complications. The authors hypothesized that preprocedure ultrasound-guided identification of the cricothyroid membrane would reduce complications associated with cricothyrotomy. A group of 47 trainees were randomized to digital palpation (n = 23) and ultrasound (n = 24) groups. Cricothyrotomy was performed on human cadavers by using the Portex device (Smiths Medical, USA). Anatomical landmarks of cadavers were graded as follows: grade 1-easy = visual landmarks; 2-moderate = requires light palpation of landmarks; 3-difficult = requires deep palpation of landmarks; and 4-impossible = landmarks not palpable. Primary outcome was the complication rate as measured by the severity of injuries. Secondary outcomes were correct device placement, failure to cannulate, and insertion time. Ultrasound guidance significantly decreased the incidence of injuries to the larynx and trachea (digital palpation: 17 of 23 = 74% vs. ultrasound: 6 of 24 = 25%; relative risk, 2.88; 95% CI, 1.39 to 5.94; P = 0.001) and increased the probability of correct insertion by 5.6 times (P = 0.043) in cadavers with difficult and impossible landmark palpation (digital palpation 8.3% vs. ultrasound 46.7%). Injuries were found in 100% of the grades 3 to 4 (difficult-impossible landmark palpation) cadavers by digital palpation compared with only 33% by ultrasound (P < 0.001). The mean (SD) insertion time was significantly longer with ultrasound than with digital palpation (196.1 s [60.6 s] vs. 110.5 s [46.9 s]; P < 0.001). Preprocedure ultrasound guidance in cadavers with poorly defined neck anatomy significantly reduces complications and improves correct insertion of the airway device in the cricothyroid membrane.

  16. Design of Multi-core Fiber Patch Panel for Space Division Multiplexing Implementations

    NASA Astrophysics Data System (ADS)

    González, Luz E.; Morales, Alvaro; Rommel, Simon; Jørgensen, Bo F.; Porras-Montenegro, N.; Tafur Monroy, Idelfonso

    2018-03-01

    A multi-core fiber (MCF) patch panel was designed, allowing easy coupling of individual signals to and from a 7-core MCF. The device was characterized, measuring insertion loss and cross talk, finding highest insertion loss and lowest crosstalk at 1300 nm with values of 9.7 dB and -36.5 dB respectively, while at 1600 nm insertion loss drops to 4.8 dB and crosstalk increases to -24.1 dB. Two MCF splices between the fan-in module, the MCF, and the fan-out module are included in the characterization, and splicing parameters are discussed.

  17. Simulators for training in ultrasound guided procedures.

    PubMed

    Farjad Sultan, Syed; Shorten, George; Iohom, Gabrielle

    2013-06-01

    The four major categories of skill sets associated with proficiency in ultrasound guided regional anaesthesia are 1) understanding device operations, 2) image optimization, 3) image interpretation and 4) visualization of needle insertion and injection of the local anesthetic solution. Of these, visualization of needle insertion and injection of local anaesthetic solution can be practiced using simulators and phantoms. This survey of existing simulators summarizes advantages and disadvantages of each. Current deficits pertain to the validation process.

  18. Repetition of the classical Boysen-Jensen and Nielsen's experiment on phototropism of oat coleoptiles.

    PubMed

    Yamada, K; Nakano, H; Yokotani-Tomita, K; Bruinsma, J; Yamamura, S; Hasegawa, K

    2000-03-01

    The classical experiment of phototropic response as reported by Boysen-Jensen and Nielsen (1926), which supports the Cholodny-Went theory, was repeated in detail. In the original experiment, etiolated oat (Avena sativa L. cv. Victory) coleoptiles with mica inserted into their tip only showed a positive response when the mica was placed parallel toward the light source and not if it was inserted perpendicularly. On the contrary, we found a positive response irrespective of whether the mica was inserted parallel or perpendicularly to the light source. Damage owing to rude splitting severely reduced the response upon perpendicular insertion. These results invalidate the Boysen-Jensen and Nielsen's experiment as a support of the Cholodny-Went theory and lend support to the Bruinsma-Hasegawa theory ascribing phototropism to the local light-induced accumulation of growth inhibitors against a background of even auxin distribution, the diffusion of auxin being unaffected.

  19. Far-field self-focusing and -defocusing radiation behaviors of the electroluminescent light sources due to negative refraction.

    PubMed

    Yin, Yu-Feng; Lin, Yen-Chen; Tsai, Tsung-Han; Shen, Yi-Chun; Huang, Jianjang

    2013-01-15

    In recent years, researchers have demonstrated negative refraction theoretically and experimentally by pumping optical power into photonic crystal (PhC) or waveguide structures. The concept of negative refraction can be used to create a perfect lens that focuses an object smaller than the wavelength. By inserting two-dimensional PhCs into the peripheral of a semiconductor light emitting structure, this study presents an electroluminescent device with negative refraction in the visible wavelength range. This approach produces polarization dependent collimation behavior in far-field radiation patterns. The modal dispersion of negative refraction results in strong group velocity modulation, and self-focusing and -defocusing behaviors are apparent from light extraction. This study further verifies experimental results by using theoretic calculations based on equifrequency contours.

  20. Reducing the contact resistance in bottom-contact-type organic field-effect transitors using an AgO x interface layer

    NASA Astrophysics Data System (ADS)

    Minagawa, Masahiro; Kim, Yeongin; Claus, Martin; Bao, Zhenan

    2017-09-01

    Bottom-contact organic field-effect transistors (OFETs) are prepared by inserting an AgO x layer between a pentacene layer and the source-drain electrodes. The contact resistance in the device is ˜8.1 kΩ·cm with an AgO x layer oxidized for 60 s but reaches 116.9 kΩ·cm with a non-oxidized Ag electrode. The drain current and mobility in the OFETs with the AgO x layer increase with the oxidization time and then gradually plateau, and this trend strongly depends on the work function of the Ag surface. Further, the hole injection is enhanced by the presence of Ag2O but inhibited by the presence of AgO.

  1. Vertically polarizing undulator with dynamic compensation of magnetic forces

    DOE PAGES

    Strelnikov, N.; Vasserman, I.; Xu, J.; ...

    2017-01-20

    As part of the R&D program of the LCLS-II project, a novel 3.4-meter-long undulator prototype with horizontal magnetic field and dynamic force compensation has recently been developed at the Advanced Photon Source (APS). Some previous steps in this development were the shorter 0.8-meter-long and 2.8-meter-long prototypes. Extensive mechanical and magnetic testing was carried out for each prototype, and each prototype was magnetically tuned using magnetic shims. Furthermore, the resulting performance of the 3.4-meter-long undulator prototype meets all requirements for the LCLS-II insertion device, including limits on the field integrals, phase errors, higher-order magnetic moments, and electron-beam trajectory for all operationalmore » gaps, as well as the reproducibility and accuracy of the gap settings.« less

  2. 78 FR 950 - Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-07

    ..., FDA- 2012-M-0965, FDA-2012-M-0968, FDA-2012-M-1011, and FDA-2012-M-1013] Medical Devices; Availability...\\ February 16, 2011. Adjustable Gastric Banding System. P100049, FDA-2012-M-0893....... Torax Medical, Inc.... Trabecular Micro- Bypass Stent and Inserter. P110007, FDA-2012-M-0734....... Abbott Medical Healon[supreg...

  3. Left ventricular assist device implantation via left thoracotomy: alternative to repeat sternotomy.

    PubMed

    Pierson, Richard N; Howser, Renee; Donaldson, Terri; Merrill, Walter H; Dignan, Rebecca J; Drinkwater, Davis C; Christian, Karla G; Butler, Javed; Chomsky, Don; Wilson, John R; Clark, Rick; Davis, Stacy F

    2002-03-01

    Repeat sternotomy for left ventricular assist device insertion may result in injury to the right heart or patent coronary grafts, complicating intraoperative and postoperative management. In 4 critically ill patients, left thoracotomy was used as an alternative to repeat sternotomy. Anastomosis of the outflow conduit to the descending thoracic aorta provided satisfactory hemodynamic support.

  4. Left ventricular assist device implantation in a patient who had previously undergone apical myectomy for hypertrophic cardiomyopathy.

    PubMed

    Cho, Yang Hyun; Deo, Salil V; Topilsky, Yan; Grogan, Martha A; Park, Soon J

    2012-03-01

    Apical hypertrophy is a rare variant of hypertropic cardiomyopathy. These patients may present with end-stage congestive heart failure subsequent to long standing diastolic dysfunction. We report the technique for left ventricular assist device insertion in a patient with previous apical myectomy for hypertrophic cardiomyopathy. © 2012 Wiley Periodicals, Inc.

  5. Microwave evaluation of electromigration susceptibility in advanced interconnects

    NASA Astrophysics Data System (ADS)

    Sunday, Christopher E.; Veksler, Dmitry; Cheung, Kin C.; Obeng, Yaw S.

    2017-11-01

    Traditional metrology has been unable to adequately address the needs of the emerging integrated circuits (ICs) at the nano scale; thus, new metrology and techniques are needed. For example, the reliability challenges in fabrication need to be well understood and controlled to facilitate mass production of through-substrate-via (TSV) enabled three-dimensional integrated circuits (3D-ICs). This requires new approaches to the metrology. In this paper, we use the microwave propagation characteristics to study the reliability issues that precede the physical damage caused by electromigration in the Cu-filled TSVs. The pre-failure microwave insertion losses and group delay are dependent on both the device temperature and the amount of current forced through the devices-under-test. The microwave insertion losses increase with the increase in the test temperature, while the group delay increases with the increase in the forced direct current magnitude. The microwave insertion losses are attributed to the defect mobility at the Cu-TiN interface, and the group delay changes are due to resistive heating in the interconnects, which perturbs the dielectric properties of the cladding dielectrics of the copper fill in the TSVs.

  6. HangOut: generating clean PSI-BLAST profiles for domains with long insertions.

    PubMed

    Kim, Bong-Hyun; Cong, Qian; Grishin, Nick V

    2010-06-15

    Profile-based similarity search is an essential step in structure-function studies of proteins. However, inclusion of non-homologous sequence segments into a profile causes its corruption and results in false positives. Profile corruption is common in multidomain proteins, and single domains with long insertions are a significant source of errors. We developed a procedure (HangOut) that, for a single domain with specified insertion position, cleans erroneously extended PSI-BLAST alignments to generate better profiles. HangOut is implemented in Python 2.3 and runs on all Unix-compatible platforms. The source code is available under the GNU GPL license at http://prodata.swmed.edu/HangOut/. Supplementary data are available at Bioinformatics online.

  7. Magnetohydrodynamic Augmented Propulsion Experiment: I. Performance Analysis and Design

    NASA Technical Reports Server (NTRS)

    Litchford, R. J.; Cole, J. W.; Lineberry, J. T.; Chapman, J. N.; Schmidt, H. J.; Lineberry, C. W.

    2003-01-01

    The performance of conventional thermal propulsion systems is fundamentally constrained by the specific energy limitations associated with chemical fuels and the thermal limits of available materials. Electromagnetic thrust augmentation represents one intriguing possibility for improving the fuel composition of thermal propulsion systems, thereby increasing overall specific energy characteristics; however, realization of such a system requires an extremely high-energy-density electrical power source as well as an efficient plasma acceleration device. This Technical Publication describes the development of an experimental research facility for investigating the use of cross-field magnetohydrodynamic (MHD) accelerators as a possible thrust augmentation device for thermal propulsion systems. In this experiment,a 1.5-MW(sub e) Aerotherm arc heater is used to drive a 2-MW(sub e) MHD accelerator. The heatsink MHD accelerator is configured as an externally diagonalized, segmented channel, which is inserted into a large-bore, 2-T electromagnet. The performance analysis and engineering design of the flow path are described as well as the parameter measurements and flow diagnostics planned for the initial series of test runs.

  8. Microfluidic device for chemical and mechanical manipulation of suspended cells

    NASA Astrophysics Data System (ADS)

    Rezvani, Samaneh; Shi, Nan; Squires, Todd M.; Schmidt, Christoph F.

    2018-01-01

    Microfluidic devices have proven to be useful and versatile for cell studies. We here report on a method to adapt microfluidic stickers made from UV-curable optical adhesive with inserted permeable hydrogel membrane micro-windows for mechanical studies of suspended cells. The windows were fabricated by optical projection lithography using scanning confocal microscopy. The device allows us to rapidly exchange embedding medium while observing and probing the cells. We characterize the device and demonstrate the function by exposing cultured fibroblasts to varying osmotic conditions. Cells can be shrunk reversibly under osmotic compression.

  9. Inflatable device for installing strain gage bridges

    NASA Technical Reports Server (NTRS)

    Cook, C. E.; Smith, G. E.; Monaghan, R. C. (Inventor)

    1983-01-01

    Methods and devices for installing in a tubular shaft multiple strain gages are disclosed with focus on a method and a device for pneumatically forcing strain gages into seated engagement with the internal surfaces of a tubular shaft in an installation of multiple strain gages in a tubular shaft. The strain gages or other electron devices are seated in a template-like component which is wrapped about a pneumatically expansible body. The component is inserted into a shaft and the body is pneumatically expanded after a suitable adhesive was applied to the surfaces.

  10. Monolithic device for modelocking and stabilization of frequency combs.

    PubMed

    Lee, C-C; Hayashi, Y; Silverman, K L; Feldman, A; Harvey, T; Mirin, R P; Schibli, T R

    2015-12-28

    We demonstrate a device that integrates a III-V semiconductor saturable absorber mirror with a graphene electro-optic modulator, which provides a monolithic solution to modelocking and noise suppression in a frequency comb. The device offers a pure loss modulation bandwidth exceeding 5 MHz and only requires a low voltage driver. This hybrid device provides not only compactness and simplicity in laser cavity design, but also small insertion loss, compared to the previous metallic-mirror-based modulators. We believe this work paves the way to portable and fieldable phase-coherent frequency combs.

  11. Intradermal needle-free powdered drug injection by a helium-powered device.

    PubMed

    Liu, John; Hogan, N Catherine; Hunter, Ian W

    2012-01-01

    We present a new method for needle-free powdered drug injection via a bench-top gas-powered device. This injector provides an alternative method of vaccine delivery to address the cold chain problem--the cost and risk of transporting temperature sensitive vaccines to developing countries. The device houses interchangeable nozzle inserts to vary orifice geometries and is capable of delivering polymer beads (1-5 µm diameter) into the dermal layer of porcine tissue. Results for injection shape and injection depth versus nozzle orifice diameter demonstrate the device's controllability.

  12. Enhancement of spin-Seebeck effect by inserting ultra-thin Fe{sub 70}Cu{sub 30} interlayer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kikuchi, D., E-mail: d.kikuchi@imr.tohoku.ac.jp; WPI Advanced Institute for Materials Research, Tohoku University, Sendai 980-8577; Spin Quantum Rectification Project, ERATO, Japan Science and Technology Agency, Sendai 980-8577

    2015-02-23

    We report the longitudinal spin-Seebeck effects (LSSEs) for Pt/Fe{sub 70}Cu{sub 30}/BiY{sub 2}Fe{sub 5}O{sub 12} (BiYIG) and Pt/BiYIG devices. The LSSE voltage was found to be enhanced by inserting an ultra-thin Fe{sub 70}Cu{sub 30} interlayer. This enhancement decays sharply with increasing the Fe{sub 70}Cu{sub 30} thickness, suggesting that it is not due to bulk phenomena, such as a superposition of conventional thermoelectric effects, but due to interface effects related to the Fe{sub 70}Cu{sub 30} interlayer. Combined with control experiments using Pt/Fe{sub 70}Cu{sub 30} devices, we conclude that the enhancement of the LSSE voltage in the Pt/Fe{sub 70}Cu{sub 30}/BiYIG devices is attributedmore » to the improvement of the spin-mixing conductance at the Pt/BiYIG interfaces.« less

  13. 21 CFR 868.5650 - Esophageal obturator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) Identification. An esophageal obturator is a device inserted through a patient's mouth to aid ventilation of the patient during emergency resuscitation by occluding (blocking) the esophagus, thereby permitting positive...

  14. Insertion of Vertically Aligned Nanowires into Living Cells by Inkjet Printing of Cells.

    PubMed

    Lee, Donggyu; Lee, Daehee; Won, Yulim; Hong, Hyeonaug; Kim, Yongjae; Song, Hyunwoo; Pyun, Jae-Chul; Cho, Yong Soo; Ryu, Wonhyoung; Moon, Jooho

    2016-03-01

    Effective insertion of vertically aligned nanowires (NWs) into cells is critical for bioelectrical and biochemical devices, biological delivery systems, and photosynthetic bioenergy harvesting. However, accurate insertion of NWs into living cells using scalable processes has not yet been achieved. Here, NWs are inserted into living Chlamydomonas reinhardtii cells (Chlamy cells) via inkjet printing of the Chlamy cells, representing a low-cost and large-scale method for inserting NWs into living cells. Jetting conditions and printable bioink composed of living Chlamy cells are optimized to achieve stable jetting and precise ink deposition of bioink for indentation of NWs into Chlamy cells. Fluorescence confocal microscopy is used to verify the viability of Chlamy cells after inkjet printing. Simple mechanical considerations of the cell membrane and droplet kinetics are developed to control the jetting force to allow penetration of the NWs into cells. The results suggest that inkjet printing is an effective, controllable tool for stable insertion of NWs into cells with economic and scale-related advantages. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. [Intrauterine devices in the immediate, early and late postabortion period].

    PubMed

    Nun, S

    1971-01-01

    2146 cases of IUD insertions after hospitalization for abortion at a hospital in Chile were studied. In 1514 cases the IUDs were inserted immediately after abortion, in 430 cases between 1-5 days after the operation, and in 202 cases between 5-40 days after. It is concluded that immediate or early insertion results in a somewhat lower retention rate, but offers the advantage of making it possible to treat a greater number of patients, many of whom would not return later to have the IUD inserted. The incidence of removal for medical causes was very low and immediate insertion was found to be harmless. The medical causes of removal were the usual ones of bleeding, pain, and infection; the most frequent cause of interruption of use was expulsion, which tends to occur during the 1st few months of use and among younger women. The probability of failure due to pregnancy was somewhat higher than in the case of insertion during the intermenstrual period. Cases of voluntary removal tend to increase after prolonged use, and a study to analyze the actual reasons for this fact is necessary.

  16. Orangutan Alu quiescence reveals possible source element: support for ancient backseat drivers

    PubMed Central

    2012-01-01

    Background Sequence analysis of the orangutan genome revealed that recent proliferative activity of Alu elements has been uncharacteristically quiescent in the Pongo (orangutan) lineage, compared with all previously studied primate genomes. With relatively few young polymorphic insertions, the genomic landscape of the orangutan seemed like the ideal place to search for a driver, or source element, of Alu retrotransposition. Results Here we report the identification of a nearly pristine insertion possessing all the known putative hallmarks of a retrotranspositionally competent Alu element. It is located in an intronic sequence of the DGKB gene on chromosome 7 and is highly conserved in Hominidae (the great apes), but absent from Hylobatidae (gibbon and siamang). We provide evidence for the evolution of a lineage-specific subfamily of this shared Alu insertion in orangutans and possibly the lineage leading to humans. In the orangutan genome, this insertion contains three orangutan-specific diagnostic mutations which are characteristic of the youngest polymorphic Alu subfamily, AluYe5b5_Pongo. In the Homininae lineage (human, chimpanzee and gorilla), this insertion has acquired three different mutations which are also found in a single human-specific Alu insertion. Conclusions This seemingly stealth-like amplification, ongoing at a very low rate over millions of years of evolution, suggests that this shared insertion may represent an ancient backseat driver of Alu element expansion. PMID:22541534

  17. Orangutan Alu quiescence reveals possible source element: support for ancient backseat drivers.

    PubMed

    Walker, Jerilyn A; Konkel, Miriam K; Ullmer, Brygg; Monceaux, Christopher P; Ryder, Oliver A; Hubley, Robert; Smit, Arian Fa; Batzer, Mark A

    2012-04-30

    Sequence analysis of the orangutan genome revealed that recent proliferative activity of Alu elements has been uncharacteristically quiescent in the Pongo (orangutan) lineage, compared with all previously studied primate genomes. With relatively few young polymorphic insertions, the genomic landscape of the orangutan seemed like the ideal place to search for a driver, or source element, of Alu retrotransposition. Here we report the identification of a nearly pristine insertion possessing all the known putative hallmarks of a retrotranspositionally competent Alu element. It is located in an intronic sequence of the DGKB gene on chromosome 7 and is highly conserved in Hominidae (the great apes), but absent from Hylobatidae (gibbon and siamang). We provide evidence for the evolution of a lineage-specific subfamily of this shared Alu insertion in orangutans and possibly the lineage leading to humans. In the orangutan genome, this insertion contains three orangutan-specific diagnostic mutations which are characteristic of the youngest polymorphic Alu subfamily, AluYe5b5_Pongo. In the Homininae lineage (human, chimpanzee and gorilla), this insertion has acquired three different mutations which are also found in a single human-specific Alu insertion. This seemingly stealth-like amplification, ongoing at a very low rate over millions of years of evolution, suggests that this shared insertion may represent an ancient backseat driver of Alu element expansion.

  18. Evaluation of dual-tip micromanometers during 21-day implantation in goats

    NASA Technical Reports Server (NTRS)

    Reister, C. A.; Koenig, S. C.; Schaub, J. D.; Ewert, D. L.; Swope, R. D.; Latham, R. D.; Fanton, J. W.; Convertino, V. A. (Principal Investigator)

    1998-01-01

    Investigative research efforts using a cardiovascular model required the determination of central circulatory haemodynamic and arterial system parameters for the evaluation of cardiovascular performance. These calculations required continuous beat-to-beat measurement of pressure within the four chambers of the heart and great vessels. Sensitivity and offset drift, longevity, and sources of error for eight 3F dual-tipped micromanometers were determined during 21 days of implantation in goats. Subjects were instrumented with pairs of chronically implanted fluid-filled access catheters in the left and right ventricles, through which dual-tipped (test) micromanometers were chronically inserted and single-tip (standard) micromanometers were acutely inserted. Acutely inserted sensors were calibrated daily and measured pressures were compared in vivo to the chronically inserted sensors. Comparison of the pre- and post-gain calibration of the chronically inserted sensors showed a mean sensitivity drift of 1.0 +/- 0.4% (99% confidence, n = 9 sensors) and mean offset drift of 5.0 +/- 1.5 mmHg (99% confidence, n = 9 sensors). Potential sources of error for these drifts were identified, and included measurement system inaccuracies, temperature drift, hydrostatic column gradients, and dynamic pressure changes. Based upon these findings, we determined that these micromanometers may be chronically inserted in high-pressure chambers for up to 17 days with an acceptable error, but should be limited to acute (hours) insertions in low-pressure applications.

  19. The New Perilaryngeal Airway (CobraPLA™)1 Is as Efficient as the Laryngeal Mask Airway (LMA™)2, But Provides Better Airway Sealing Pressures

    PubMed Central

    Akça, Ozan; Wadhwa, Anupama; Sengupta, Papiya; Durrani, Jaleel; Hanni, Keith; Wenke, Mary; Yücel, Yüksel; Lenhardt, Rainer; Doufas, Anthony G.; Sessler, Daniel I.

    2006-01-01

    The Laryngeal Mask Airway (LMA) is a frequently-used efficient airway device, yet it sometimes seals poorly, thus reducing the efficacy of positive-pressure ventilation. The Perilaryngeal Airway (CobraPLA) is a novel airway device with a larger pharyngeal cuff (when inflated). We tested the hypothesis that the CobraPLA was superior to LMA with regard to insertion time and airway sealing pressure and comparable to LMA in airway adequacy and recovery characteristics. After midazolam and fentanyl, 81 ASA I-II outpatients having elective surgery were randomized to receive an LMA or CobraPLA. Anesthesia was induced with propofol (2.5 mg/kg, IV), and the airway inserted. We measured 1) insertion time; 2) adequacy of the airway (no leak at 15-cm-H2O peak pressure or tidal volume of 5 ml/kg); 3) airway sealing pressure; 4) number of repositioning attempts; and 5) sealing quality (no leak at tidal volume of 8 ml/kg). At the end of surgery, gastric insufflation, postoperative sore throat, dysphonia, and dysphagia were evaluated. Data were compared with unpaired t-tests, chi-square tests, or Fisher’s Exact tests; P<0.05 was significant. Patient characteristics, insertion times, airway adequacy, number of repositioning attempts, and recovery were similar in each group. Airway sealing pressure was significantly greater with CobraPLA (23±6 cm H2O) than LMA (18±5 cm H2O, P<0.001). The CobraPLA has insertion characteristics similar to LMA, but better airway sealing capabilities. PMID:15281543

  20. Inverted, Organic WORM Device Based on PEDOT:PSS with Very Low Turn-On Voltage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nawrocki, Robert A.; Galiger, Erin M.; Ostrowski, David P.

    An organic Write-Once-Read-Many (WORM) device based on poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS) as the active layer was fabricated with an inverted architecture. Insertion of an ultrathin layer of poly(methylmethacrylate) (PMMA) between the bottom electrode and the PEDOT:PSS resulted in a systematic and substantial decrease in turn-on voltage, from 7.0 V to less than 1.0 V. An optimal thickness of the PMMA layer was found to yield the lowest consistent turn-on voltage of ~0.8 V, with 0.5 V being the lowest value of all fabricated devices. The switching mechanism was attributed to filamentary doping of the PEDOT:PSS. Insertion of the PMMA acted tomore » protect the underlying ZnO from being etched by the acidic PEDOT:PSS as well as to improve its wetting properties. Moreover, devices were demonstrated on both ITO and aluminum bottom electrodes, with aluminum yielding the highest ON/OFF ratios in the study. Owing to their inverted architecture, the devices demonstrated good stability, and the retention time of the ON-state was determined to be greater than twenty months while stored in air for devices with ITO bottom electrodes. Blade-coating was demonstrated as a viable processing technique for applications requiring rapid or large-area manufacturing in addition to deposition via spin-coating.« less

  1. Imaging findings in essure related complications.

    PubMed

    Djeffal, Hachem; Blouet, Marie; Pizzoferrato, Anne-Cécile; Vardon, Delphine; Belloy, Frederique; Pelage, Jean-Pierre

    2018-06-21

    Tubal sterilization with Essure inserts has become a prevalent alternative to laparoscopic sterilization because of its minimal invasiveness. It is a well-tolerated ambulatory procedure that provides reliable permanent contraception without the risks associated with laparoscopic surgery and general anesthesia. Correct positioning of the Essure device is necessary to achieve the fibrotic reaction induced by the polyethylene terephthalate fibers, subsequently resulting in tubal occlusion usually within 3 months. After uneventful procedures with satisfactory bilateral placement, only the correct position of the devices needs to be confirmed at follow-up. The imaging techniques used to asses Essure devices may vary depending on the country and its recommendations. The gold standard test to ascertain tubal occlusion remains the hysterosalpingography but after uneventful procedures, vaginal-ultrasound proved to be a reliable alternative to confirm the proper position of the inserts. Radiologists have been increasingly confronted to post procedural evaluations and despite the efficiency rate of the Essure device, its use still exposes to a low risk of complications and malfunctions such as unwanted pregnancies, device misplacement, tubal or uterine perforation, and chronic pelvic pain. Unintended pregnancies are mostly due to patient or physician non-compliance and misinterpretation of post procedural examinations by radiologists which emphasizes the importance of their training in Essure device assessment. This pictorial review discusses the imaging methods used to asses Essure implants and illustrates the possible complications related to them.

  2. A new adjustable parallel drill guide for internal fixation of femoral neck fracture: a developmental and experimental study.

    PubMed

    Yuenyongviwat, Varah; Tuntarattanapong, Pakjai; Tangtrakulwanich, Boonsin

    2016-01-11

    Internal fixation is one treatment for femoral neck fracture. Some devices and techniques reported improved accuracy and decreased fluoroscopic time. However, these are not widely used nowadays due to the lack of available special instruments and techniques. To improve the surgical procedure, the authors designed a new adjustable drill guide and tested the efficacy of the device. The authors developed a new adjustable drill guide for cannulated screw guide wire insertion for multiple screw fixation. Eight orthopaedic surgeons performed the experimental study to evaluate the efficacy of this device. Each surgeon performed guide wire insertion for multiple screw fixation in six synthetic femurs: three times with the new device and three times with the conventional technique. The fluoroscopic time, operative time and surgeon satisfaction were evaluated. In the operations with the new adjustable drill guide, the fluoroscopic and operative times were significantly lower than the operations with the conventional technique (p < 0.05). The mean score for the level of satisfaction of this device was also statistically significantly better (p = 0.02) than the conventional technique. The fluoroscopic and operative times with the new adjustable drill guide were reduced for multiple screw fixation of femoral neck fracture and the satisfaction of the surgeons was good.

  3. Insertion devices for DORIS III (invited)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pflueger, J.

    1992-01-01

    Recently, a major reconstruction of the electron storage ring DORIS II, the DORIS III project, has been completed (W. Brefeld, H. Nesemann, and J. Rossbach, {ital Proceedings} {ital of} {ital the} {ital European} {ital Particle} {ital Accelerator} {ital Conference}, Rome (World Scientific, Singapore, 1988), p. 2389). Figure 1 shows an overview of the new ring. Originally DORIS II had a twofold symmetry. In part C each of the two dipole magnets adjacing to the 65-m-long straight section was replaced by three corresponding weaker ones. In this way a total of seven straight sections for insertion devices are provided. Six ofmore » them are 4-m long and the one in the center is only 2.7-m long. After extensive discussions with the user groups involved, four x-ray wigglers, one asymmetric hybrid structure, one x-ray undulator, and one XUV multiple undulator of the revolver type have been proposed for six of the sections (J. Pflueger and P. Gurtler, Nucl. Instrum. Methods A {bold 287}, 628 (1990)). One section is presently still free. All devices are either in construction or have already been completed and installed. In this contribution the mechanical and magnetic design of these devices will be described. Results of magnetic measurements of those devices which are already completed will be given in more detail.« less

  4. Simultaneous Antegrade-Retrograde Subintimal Revascularization of a Femoropopliteal Chronic Total Occlusion by a Reentry Device-Facilitated Puncture of a Retrogradely Inserted Balloon.

    PubMed

    Goltz, Jan Peter; Anton, Susanne; Wiedner, Marcus; Barkhausen, Jörg; Stahlberg, Erik

    2017-08-01

    To report a rendezvous technique for subintimal revascularization of a chronic total occlusion (CTO) of the superficial femoral artery (SFA). This maneuver is appropriate after failure to cross a long SFA CTO via intra- and subintimal approaches from the ipsilateral femoral as well as retrograde posterior tibial artery (PTA) access sites. After predilation of the subintimal space from the femoral access, a reentry device was placed at the level of the first popliteal artery segment. A balloon was delivered via the retrograde PTA access and inflated at the corresponding level of the reentry device. The balloon was punctured with the needle of the reentry device under fluoroscopic control, and a 0.014-inch guidewire was placed within the punctured balloon. The balloon and the antegrade guidewire were retracted from the retrograde access while the guidewire was gently pushed from the femoral site. Conventional balloon angioplasty of the SFA occlusion was performed via the femoral access, followed by overlapping stent-graft implantation. Complete revascularization of the CTO was documented. In selected cases a transfemoral reentry device-assisted puncture of a retrogradely inserted balloon within the subintimal space may facilitate a rendezvous and revascularization if standard techniques to cross long CTOs have failed.

  5. 20 Gbit/s error free transmission with ~850 nm GaAs-based vertical cavity surface emitting lasers (VCSELs) containing InAs-GaAs submonolayer quantum dot insertions

    NASA Astrophysics Data System (ADS)

    Lott, J. A.; Shchukin, V. A.; Ledentsov, N. N.; Stinz, A.; Hopfer, F.; Mutig, A.; Fiol, G.; Bimberg, D.; Blokhin, S. A.; Karachinsky, L. Y.; Novikov, I. I.; Maximov, M. V.; Zakharov, N. D.; Werner, P.

    2009-02-01

    We report on the modeling, epitaxial growth, fabrication, and characterization of 830-845 nm vertical cavity surface emitting lasers (VCSELs) that employ InAs-GaAs quantum dot (QD) gain elements. The GaAs-based VCSELs are essentially conventional in design, grown by solid-source molecular beam epitaxy, and include top and bottom gradedheterointerface AlGaAs distributed Bragg reflectors, a single selectively-oxidized AlAs waveguiding/current funneling aperture layer, and a quasi-antiwaveguiding microcavity. The active region consists of three sheets of InAs-GaAs submonolayer insertions separated by AlGaAs matrix layers. Compared to QWs the InAs-GaAs insertions are expected to offer higher exciton-dominated modal gain and improved carrier capture and retention, thus resulting in superior temperature stability and resilience to degradation caused by operating at the larger switching currents commonly employed to increase the data rates of modern optical communication systems. We investigate the robustness and temperature performance of our QD VCSEL design by fabricating prototype devices in a high-frequency ground-sourceground contact pad configuration suitable for on-wafer probing. Arrays of VCSELs are produced with precise variations in top mesa diameter from 24 to 36 μm and oxide aperture diameter from 1 to 12 μm resulting in VCSELs that operate in full single-mode, single-mode to multi-mode, and full multi-mode regimes. The single-mode QD VCSELs have room temperature threshold currents below 0.5 mA and peak output powers near 1 mW, whereas the corresponding values for full multi-mode devices range from about 0.5 to 1.5 mA and 2.5 to 5 mW. At 20°C we observe optical transmission at 20 Gb/s through 150 m of OM3 fiber with a bit error ratio better than 10-12, thus demonstrating the great potential of our QD VCSELs for applications in next-generation short-distance optical data communications and interconnect systems.

  6. Diabetic Coma

    MedlinePlus

    ... unawareness). CGMs are devices that use a small sensor inserted underneath the skin to track trends in ... may help you control your glucose better. Drink alcohol with caution. Because alcohol can have an unpredictable ...

  7. Temporomandibular Joint Dysfunction

    MedlinePlus

    ... or applying ice packs. It may also include pain medicines or devices to insert in your mouth. In very rare cases, you might need surgery. NIH: National Institute of Dental and Craniofacial Research

  8. Increased drop formation frequency via reduction of surfactant interactions in flow-focusing microfluidic devices.

    PubMed

    Josephides, Dimitris N; Sajjadi, Shahriar

    2015-01-27

    Glass capillary based microfluidic devices are able to create extremely uniform droplets, when formed under the dripping regime, at low setup costs due to their ease of manufacture. However, as they are rarely parallelized, simple methods to increase droplet production from a single device are sought. Surfactants used to stabilize drops in such systems often limit the maximum flow rate that highly uniform drops can be produced due to the lowering interfacial tension causing jetting. In this paper we show that by simple design changes we can limit the interactions of surfactants and maximize uniform droplet production. Three flow-focused configurations are explored: a standard glass capillary device (consisting of a single round capillary inserted into a square capillary), a nozzle fed device, and a surfactant shielding device (both consisting of two round capillaries inserted into either end of a square capillary). In principle, the maximum productivity of uniform droplets is achieved if surfactants are not present. It was found that surfactants in the standard device greatly inhibit droplet production by means of interfacial tension lowering and tip-streaming phenomena. In the nozzle fed configuration, surfactant interactions were greatly limited, yielding flow rates comparable to, but lower than, a surfactant-free system. In the surfactant shielding configuration, flow rates were equal to that of a surfactant-free system and could make uniform droplets at rates an order of magnitude above the standard surfactant system.

  9. Intraoperative seizure and cerebrospinal fluid leak during adult cochlear implant surgery.

    PubMed

    Musser, Alexander B; Golub, Justin S; Samy, Ravi N; Phero, James C

    2016-01-01

    To report a rare case of cerebrospinal fluid gusher and subsequent seizure immediately after cochlear implant electrode insertion. After the cochlear implant electrode was inserted, brisk flow of 10 mL of cerebrospinal fluid was seen. The electrode was promptly inserted and the leak was additionally sealed with fascia. Seconds later, the patient had a tonic-clonic seizure lasting 30 seconds. Two additional episodes occurred during the case. Her postoperative course was uneventful with no subsequent seizures. The device has been successfully activated. Intervention & Technique: Postoperative imaging showed correct intracochlear placement of the electrode as well as an incidental enlarged vestibular aqueduct. Neurology consultation including electroencephalogram was unremarkable. To our knowledge, this is the first report of a seizure temporally associated with cochlear implant electrode insertion. The significance and possible casual relationship between these two events is discussed.

  10. Combinatorial materials research applied to the development of new surface coatings VII: An automated system for adhesion testing

    NASA Astrophysics Data System (ADS)

    Chisholm, Bret J.; Webster, Dean C.; Bennett, James C.; Berry, Missy; Christianson, David; Kim, Jongsoo; Mayo, Bret; Gubbins, Nathan

    2007-07-01

    An automated, high-throughput adhesion workflow that enables pseudobarnacle adhesion and coating/substrate adhesion to be measured on coating patches arranged in an array format on 4×8in.2 panels was developed. The adhesion workflow consists of the following process steps: (1) application of an adhesive to the coating array; (2) insertion of panels into a clamping device; (3) insertion of aluminum studs into the clamping device and onto coating surfaces, aligned with the adhesive; (4) curing of the adhesive; and (5) automated removal of the aluminum studs. Validation experiments comparing data generated using the automated, high-throughput workflow to data obtained using conventional, manual methods showed that the automated system allows for accurate ranking of relative coating adhesion performance.

  11. A new method and device of aligning patient setup lasers in radiation therapy

    PubMed Central

    Hwang, Ui‐Jung; Jo, Kwanghyun; Kwak, Jung Won; Choi, Sang Hyoun; Jeong, Chiyoung; Kim, Mi Young; Jeong, Jong Hwi; Shin, Dongho; Lee, Se Byeong; Park, Jeong‐Hoon; Park, Sung Yong; Kim, Siyong

    2016-01-01

    The aim of this study is to develop a new method to align the patient setup lasers in a radiation therapy treatment room and examine its validity and efficiency. The new laser alignment method is realized by a device composed of both a metallic base plate and a few acrylic transparent plates. Except one, every plate has either a crosshair line (CHL) or a single vertical line that is used for alignment. Two holders for radiochromic film insertion are prepared in the device to find a radiation isocenter. The right laser positions can be found optically by matching the shadows of all the CHLs in the gantry head and the device. The reproducibility, accuracy, and efficiency of laser alignment and the dependency on the position error of the light source were evaluated by comparing the means and the standard deviations of the measured laser positions. After the optical alignment of the lasers, the radiation isocenter was found by the gantry and collimator star shots, and then the lasers were translated parallel to the isocenter. In the laser position reproducibility test, the mean and standard deviation on the wall of treatment room were 32.3±0.93 mm for the new method whereas they were 33.4±1.49 mm for the conventional method. The mean alignment accuracy was 1.4 mm for the new method, and 2.1 mm for the conventional method on the walls. In the test of the dependency on the light source position error, the mean laser position was shifted just by a similar amount of the shift of the light source in the new method, but it was greatly magnified in the conventional method. In this study, a new laser alignment method was devised and evaluated successfully. The new method provided more accurate, more reproducible, and faster alignment of the lasers than the conventional method. PACS numbers: 87.56.Fc, 87.53.Bn, 87.53.Kn, 87.53.Ly, 87.55.Gh PMID:26894331

  12. Device-packaging method and apparatus for optoelectronic circuits

    DOEpatents

    Zortman, William A.; Henry, Michael David; Jarecki, Jr., Robert L.

    2017-04-25

    An optoelectronic device package and a method for its fabrication are provided. The device package includes a lid die and an active die that is sealed or sealable to the lid die and in which one or more optical waveguides are integrally defined. The active die includes one or more active device regions, i.e. integral optoelectronic devices or etched cavities for placement of discrete optoelectronic devices. Optical waveguides terminate at active device regions so that they can be coupled to them. Slots are defined in peripheral parts of the active dies. At least some of the slots are aligned with the ends of integral optical waveguides so that optical fibers or optoelectronic devices inserted in the slots can optically couple to the waveguides.

  13. SETA Support for the DARPA Microelectronics Technology Insertion Program of the Microelectronics Technology Office

    DTIC Science & Technology

    1992-08-17

    Conclusions. Key personnel planned and administered the 193-nm lithography SBIR workshop on May 7, 1992 as well as planned the GaAs Insertion...converters can use Josephson junctions (JJ) to improve performance. Superconductive quantum interference devices (SQUIDs), such as JJs, are used to form...forward control of a lithography stepper. Mark Conner at Booz-Allen has copies of the charts. You should take a few minutes to review them. I asked Costos

  14. The effects of simulated patients and simulated gynecologic models on student anxiety in providing IUD services.

    PubMed

    Khadivzadeh, Talat; Erfanian, Fatemeh

    2012-10-01

    Midwifery students experience high levels of stress during their initial clinical practices. Addressing the learner's source of anxiety and discomfort can ease the learning experience and lead to better outcomes. The aim of this study was to find out the effect of a simulation-based course, using simulated patients and simulated gynecologic models on student anxiety and comfort while practicing to provide intrauterine device (IUD) services. Fifty-six eligible midwifery students were randomly allocated into simulation-based and traditional training groups. They participated in a 12-hour workshop in providing IUD services. The simulation group was trained through an educational program including simulated gynecologic models and simulated patients. The students in both groups then practiced IUD consultation and insertion with real patients in the clinic. The students' anxiety in IUD insertion was assessed using the "Spielberger anxiety test" and the "comfort in providing IUD services" questionnaire. There were significant differences between students in 2 aspects of anxiety including state (P < 0.001) and trait (P = 0.024) and the level of comfort (P = 0.000) in providing IUD services in simulation and traditional groups. "Fear of uterine perforation during insertion" was the most important cause of students' anxiety in providing IUD services, which was reported by 74.34% of students. Simulated patients and simulated gynecologic models are effective in optimizing students' anxiety levels when practicing to deliver IUD services. Therefore, it is recommended that simulated patients and simulated gynecologic models be used before engaging students in real clinical practice.

  15. A low insertion loss GaAs pHEMT switch utilizing dual n +-doping AlAs etching stop layers design

    NASA Astrophysics Data System (ADS)

    Chien, Feng-Tso; Lin, Da-Wei; Yang, Chih-Wei; Fu, Jeffrey S.; Chiu, Hsien-Chin

    2010-03-01

    A low insertion loss single-pole-single-throw (SPST) pseudomorphic high electron mobility transistor (pHEMT) switch utilizing the n +-type doping in AlAs etching stop layer was fabricated and investigated. This novel design reduces device sheet resistance resulting in an improvement of dc and rf power performance. In addition, the gate recess selectivity for GaAs/AlAs interface was not sacrificed after highly n +-type doping in AlAs etching stop layer. The pHEMT with n +-AlAs etching stop layer, also named Modified pHEMT (M-pHEMT), demonstrated a lower sheet resistance ( Rsh) of 65.9 Ω/γ, a higher maximum drain-to-source current ( Idmax) of 317.8 mA/mm and a higher peak transconductance ( gm) of 259.3 mS/mm which are superior to standard pHEMT performance with values of 71.9 Ω/γ, 290.3 mA/mm and 252.1 mS/mm, respectively. Due to a significant sheet resistance improvement from this novel epitaxial design, an SPST pHEMT switch was realized to manifest its industrial application potential. The results achieved an on-state insertion loss of 1.42 dB, an off-state isolation of 13.02 dB at 0.9 GHz, which were superior to traditional pHEMT switch under same condition of operation with values of 1.68 dB and 11.42 dB, respectively. It is proved that dual n +-doping AlAs etching stop layers scheme is beneficial for low loss microwave switches applications.

  16. Beam dynamics and expected performance of Sweden's new storage-ring light source: MAX IV

    NASA Astrophysics Data System (ADS)

    Leemann, S. C.; Andersson, Å.; Eriksson, M.; Lindgren, L.-J.; Wallén, E.; Bengtsson, J.; Streun, A.

    2009-12-01

    MAX IV will be Sweden’s next-generation high-performance synchrotron radiation source. The project has recently been granted funding and construction is scheduled to begin in 2010. User operation for a broad and international user community should commence in 2015. The facility is comprised of two storage rings optimized for different wavelength ranges, a linac-based short-pulse facility and a free-electron laser for the production of coherent radiation. The main radiation source of MAX IV will be a 528 m ultralow emittance storage ring operated at 3 GeV for the generation of high-brightness hard x rays. This storage ring was designed to meet the requirements of state-of-the-art insertion devices which will be installed in nineteen 5 m long dispersion-free straight sections. The storage ring is based on a novel multibend achromat design delivering an unprecedented horizontal bare lattice emittance of 0.33 nm rad and a vertical emittance below the 8 pm rad diffraction limit for 1 Å radiation. In this paper we present the beam dynamics considerations behind this storage-ring design and detail its expected unique performance.

  17. Shielding calculations for the National Synchrotron Light Source-II experimental beamlines

    NASA Astrophysics Data System (ADS)

    Job, Panakkal K.; Casey, William R.

    2013-01-01

    Brookhaven National Laboratory is in the process of building a new Electron storage ring for scientific research using synchrotron radiation. This facility, called the "National Synchrotron Light Source II" (NSLS-II), will provide x-ray radiation of ultra-high brightness and exceptional spatial and energy resolution. It will also provide advanced insertion devices, optics, detectors, and robotics, designed to maximize the scientific output of the facility. The project scope includes the design of an electron storage ring and the experimental beamlines, which stores a maximum of 500 mA electron beam current at an energy of 3.0 GeV. When fully built there will be at least 58 beamlines using synchrotron radiation for experimental programs. It is planned to operate the facility primarily in a top-off mode, thereby maintaining the maximum variation in the synchrotron radiation flux to <1%. Because of the very demanding requirements for synchrotron radiation brilliance for the experiments, each of the 58 beamlines will be unique in terms of the source properties and experimental configuration. This makes the shielding configuration of each of the beamlines unique. The shielding calculation methodology and the results for five representative beamlines of NSLS-II, have been presented in this paper.

  18. 21 CFR 888.3060 - Spinal intervertebral body fixation orthosis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... each of a series of vertebral bodies. An eye-type screw is inserted in a hole in the center of each of the plates. A braided cable is threaded through each eye-type screw. The cable is tightened with a tension device and it is fastened or crimped at each eye-type screw. The device is used to apply force to...

  19. 21 CFR 888.3060 - Spinal intervertebral body fixation orthosis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... each of a series of vertebral bodies. An eye-type screw is inserted in a hole in the center of each of the plates. A braided cable is threaded through each eye-type screw. The cable is tightened with a tension device and it is fastened or crimped at each eye-type screw. The device is used to apply force to...

  20. MEMS Reliability Assurance Guidelines for Space Applications

    NASA Technical Reports Server (NTRS)

    Stark, Brian (Editor)

    1999-01-01

    This guide is a reference for understanding the various aspects of microelectromechanical systems, or MEMS, with an emphasis on device reliability. Material properties, failure mechanisms, processing techniques, device structures, and packaging techniques common to MEMS are addressed in detail. Design and qualification methodologies provide the reader with the means to develop suitable qualification plans for the insertion of MEMS into the space environment.

  1. Aids to Computer-Based Multimedia Learning: A Comparison of Human Tutoring and Computer Support

    ERIC Educational Resources Information Center

    Rodicio, H. Garcia; Sanchez, E.

    2012-01-01

    Learners are usually provided with support devices because they find it difficult to learn from multimedia presentations. A key question, with no clear answer so far, is how best to present these support devices. One possibility is to insert them into the multimedia presentation (canned support), while another is to have a human agent provide them…

  2. FABRICATION OF NEUTRON SOURCES

    DOEpatents

    Birden, J.H.

    1959-01-20

    A method is presented for preparing a more efficient neutron source comprising inserting in a container a quantity of Po-210, inserting B powder coated with either Ag, Pt, or Ni. The container is sealed and then slowly heated to about 450 C to volatilize the Po and effect combination of the coated powder with the Po. The neutron flux emitted by the unit is moritored and the heating step is terminated when the flux reaches a maximum or selected level.

  3. Plasma jet ignition device

    DOEpatents

    McIlwain, Michael E.; Grant, Jonathan F.; Golenko, Zsolt; Wittstein, Alan D.

    1985-01-15

    An ignition device of the plasma jet type is disclosed. The device has a cylindrical cavity formed in insulating material with an electrode at one end. The other end of the cylindrical cavity is closed by a metal plate with a small orifice in the center which plate serves as a second electrode. An arc jumping between the first electrode and the orifice plate causes the formation of a highly-ionized plasma in the cavity which is ejected through the orifice into the engine cylinder area to ignite the main fuel mixture. Two improvements are disclosed to enhance the operation of the device and the length of the plasma plume. One improvement is a metal hydride ring which is inserted in the cavity next to the first electrode. During operation, the high temperature in the cavity and the highly excited nature of the plasma breaks down the metal hydride, liberating hydrogen which acts as an additional fuel to help plasma formation. A second improvement consists of a cavity insert containing a plurality of spaced, metal rings. The rings act as secondary spark gap electrodes reducing the voltage needed to maintain the initial arc in the cavity.

  4. TM-pass polarizer based on multilayer graphene polymer waveguide

    NASA Astrophysics Data System (ADS)

    Cai, Ke-su; Li, Yue-e.; Wei, Wen-jing; Mu, Xi-jiao; Ma, A.-ning; Wang, Zhong; Song, Dan-ming

    2018-05-01

    A TM-pass polarizer based on multilayer graphene polymer waveguide is proposed and theoretically analyzed. The mode properties, the extinction ratio, the insertion loss and the bandwidth are also discussed. The results show that a TM-pass polarizer, which only guides the TM mode, can be achieved by multilayer graphene polymer waveguide. With length of 150 μm, the proposed polarizer can achieve extinction ratio of 33 dB and insertion loss of 0.5 dB at optical wavelength of 1.55 μm. This device has an excellent performance, including large extinction ratio and low insertion loss within the spectral range from 1.45 μm to 1.6 μm.

  5. 42 CFR 414.228 - Prosthetic and orthotic devices.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... therapeutic shoes. The payment rules specified in paragraphs (a) and (b) of this section are applicable to custom molded and extra depth shoes, modifications, and inserts (therapeutic shoes) furnished after...

  6. 42 CFR 414.228 - Prosthetic and orthotic devices.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... therapeutic shoes. The payment rules specified in paragraphs (a) and (b) of this section are applicable to custom molded and extra depth shoes, modifications, and inserts (therapeutic shoes) furnished after...

  7. Pacemaker (image)

    MedlinePlus

    A pacemaker is a small, battery-operated electronic device which is inserted under the skin to help the heart beat regularly and at an appropriate rate. The pacemaker has leads that travel through a large vein ...

  8. Comparison of the Fluid Resuscitation Rate with and without External Pressure Using Two Intraosseous Infusion Systems for Adult Emergencies, the CITRIN (Comparison of InTRaosseous infusion systems in emergency medicINe)-Study

    PubMed Central

    Gries, André; Hossfeld, Björn; Bechmann, Ingo; Bernhard, Michael

    2015-01-01

    Introduction Intraosseous infusion is recommended if peripheral venous access fails for cardiopulmonary resuscitation or other medical emergencies. The aim of this study, using body donors, was to compare a semi-automatic (EZ-IO®) device at two insertion sites and a sternal intraosseous infusion device (FASTR™). Methods Twenty-seven medical students being inexperienced first-time users were randomized into three groups using EZ-IO and FASTR. The following data were evaluated: attempts required for successful placement, insertion time and flow rates with and without external pressure to the infusion. Results The first-pass insertion success of the EZ-IO tibia, EZ-IO humerus and FASTR was 91%, 77%, and 95%, respectively. Insertion times (MW±SD) did not show significant differences with 17±7 (EZ-IO tibia) vs. 29±42 (EZ-IO humerus) vs. 33±21 (FASTR), respectively. One-minute flow rates using external pressures between 0 mmHg and 300 mmHg ranged between 27±5 to 69±54 ml/min (EZ-IO tibia), 16±3 to 60±44 ml/min (EZ-IO humerus) and 53±2 to 112±47 ml/min (FASTR), respectively. Concerning pressure-related increases in flow rates, negligible correlations were found for the EZ-IO tibia in all time frames (c = 0.107–0.366; p≤0.013), moderate positive correlations were found for the EZ-IO humerus after 5 minutes (c = 0.489; p = 0.021) and strong positive correlations were found for the FASTR in all time frames (c = 0.63–0.80; p≤0.007). Post-hoc statistical power was 0.62 with the given sample size. Conclusions The experiments with first-time users applying EZ-IO and FASTR in body donors indicate that both devices may be effective intraosseous infusion devices, likely suitable for fluid resuscitation using a pressure bag. Variations in flow rate may limit their reliability. Larger sample sizes will prospectively be required to substantiate our findings. PMID:26630579

  9. Comparison of the Fluid Resuscitation Rate with and without External Pressure Using Two Intraosseous Infusion Systems for Adult Emergencies, the CITRIN (Comparison of InTRaosseous infusion systems in emergency medicINe)-Study.

    PubMed

    Hammer, Niels; Möbius, Robert; Gries, André; Hossfeld, Björn; Bechmann, Ingo; Bernhard, Michael

    2015-01-01

    Intraosseous infusion is recommended if peripheral venous access fails for cardiopulmonary resuscitation or other medical emergencies. The aim of this study, using body donors, was to compare a semi-automatic (EZ-IO®) device at two insertion sites and a sternal intraosseous infusion device (FASTR™). Twenty-seven medical students being inexperienced first-time users were randomized into three groups using EZ-IO and FASTR. The following data were evaluated: attempts required for successful placement, insertion time and flow rates with and without external pressure to the infusion. The first-pass insertion success of the EZ-IO tibia, EZ-IO humerus and FASTR was 91%, 77%, and 95%, respectively. Insertion times (MW ± SD) did not show significant differences with 17 ± 7 (EZ-IO tibia) vs. 29 ± 42 (EZ-IO humerus) vs. 33 ± 21 (FASTR), respectively. One-minute flow rates using external pressures between 0 mmHg and 300 mmHg ranged between 27 ± 5 to 69 ± 54 ml/min (EZ-IO tibia), 16 ± 3 to 60 ± 44 ml/min (EZ-IO humerus) and 53 ± 2 to 112 ± 47 ml/min (FASTR), respectively. Concerning pressure-related increases in flow rates, negligible correlations were found for the EZ-IO tibia in all time frames (c = 0.107-0.366; p ≤ 0.013), moderate positive correlations were found for the EZ-IO humerus after 5 minutes (c = 0.489; p = 0.021) and strong positive correlations were found for the FASTR in all time frames (c = 0.63-0.80; p ≤ 0.007). Post-hoc statistical power was 0.62 with the given sample size. The experiments with first-time users applying EZ-IO and FASTR in body donors indicate that both devices may be effective intraosseous infusion devices, likely suitable for fluid resuscitation using a pressure bag. Variations in flow rate may limit their reliability. Larger sample sizes will prospectively be required to substantiate our findings.

  10. The carbene insertion methodology for the catalytic functionalization of unreactive hydrocarbons: no classical C-H activation, but efficient C-H functionalization.

    PubMed

    Díaz-Requejo, M Mar; Belderrain, Tomás R; Nicasio, M Carmen; Pérez, Pedro J

    2006-12-21

    This contribution intends to highlight the use of the metal-catalyzed functionalization of unreactive carbon-hydrogen bonds by the carbene insertion methodology, that employs diazo compounds as the carbene source.

  11. SOURCE CHARACTERIZATION OF AIR FRESHENERS

    EPA Science Inventory

    The paper discusses research in which five air fresheners of two styles were analyzed for their constituent volatile organic compounds. Both styles were refills to be inserted into heated electric plug-in units; one refill released the fragrance from a gel pack insert and the oth...

  12. Microfluidic devices fabricated in poly(methyl methacrylate) using hot-embossing with integrated sampling capillary and fiber optics for fluorescence detection.

    PubMed

    Qi, Shize; Liu, Xuezhu; Ford, Sean; Barrows, James; Thomas, Gloria; Kelly, Kevin; McCandless, Andrew; Lian, Kun; Goettert, Jost; Soper, Steven A

    2002-05-01

    High-aspect-ratio microstructures have been prepared using hot-embossing techniques in poly(methyl methacrylate) (PMMA) from Ni-based molding dies prepared using LIGA (Lithographie, Galvanoformung, Abformung). Due to the small amount of mask undercutting associated with X-ray lithography and the high energy X-ray beam used during photoresist patterning, deep structures with sharp and smooth sidewalls have been prepared. The Ni-electroforms produced devices with minimal replication errors using hot-embossing at a turn around time of approximately 5 min per device. In addition, several different polymers (with different glass transition temperatures) could be effectively molded with these Ni-electroforms and many devices (>300) molded with the same master without any noticeable degradation. The PMMA devices consisted of deep and narrow channels for insertion of a capillary for the automated electrokinetic loading of sample into the microfluidic device and also, a pair of optical fibers for shuttling laser light to the detection zone and collecting the resulting emission for fluorescence analysis. Electrophoretic separations of double-stranded DNA ladders Phi X174 digested with Hae III) were performed with fluorescence detection accomplished using near-IR excitation. It was found that the narrow width of the channels did not contribute significantly to electrophoretic zone broadening and the plate numbers generated in the extended length separation channel allowed sorting of the 271/281 base pair fragments associated with this sizing ladder when electrophoresed in methylcellulose entangled polymer solutions. The dual fiber detector produced sub-attomole detection limits with the entire detector, including laser source, electronics and photon transducer, situated in a single box measuring 3'' x 10" x 14".

  13. 21 CFR 876.5130 - Urological catheter and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... device that is inserted through the urethra and used to pass fluids to or from the urinary tract. This..., coude catheters, balloon retention type catheters, straight catheters, upper urinary tract catheters...

  14. 42 CFR 414.228 - Prosthetic and orthotic devices.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Payment for therapeutic shoes. The payment rules specified in paragraphs (a) and (b) of this section are applicable to custom molded and extra depth shoes, modifications, and inserts (therapeutic shoes) furnished...

  15. 42 CFR 414.228 - Prosthetic and orthotic devices.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) Payment for therapeutic shoes. The payment rules specified in paragraphs (a) and (b) of this section are applicable to custom molded and extra depth shoes, modifications, and inserts (therapeutic shoes) furnished...

  16. Shock Wave-Stimulated Periosteum for Cartilage Repair

    DTIC Science & Technology

    2012-12-01

    inserted into the tibial periosteum of 6 animals to measure the actual shock waveform in the tissue for two ESW doses (energy densities). In 12 goats... tibial periosteum stimulated by one of the 2 doses of ESWs (n=6) will be harvested, 4 days post-treatment, as an autograft for implantation into one 1...locations of sensor away from the head of the ESW device. 1.b. Insert a pressure sensor into the periosteum of the right proximal tibial of6 goats to

  17. Development of a virtual reality haptic Veress needle insertion simulator for surgical skills training.

    PubMed

    Okrainec, A; Farcas, M; Henao, O; Choy, I; Green, J; Fotoohi, M; Leslie, R; Wight, D; Karam, P; Gonzalez, N; Apkarian, J

    2009-01-01

    The Veress needle is the most commonly used technique for creating the pneumoperitoneum at the start of a laparoscopic surgical procedure. Inserting the Veress needle correctly is crucial since errors can cause significant harm to patients. Unfortunately, this technique can be difficult to teach since surgeons rely heavily on tactile feedback while advancing the needle through the various layers of the abdominal wall. This critical step in laparoscopy, therefore, can be challenging for novice trainees to learn without adequate opportunities to practice in a safe environment with no risk of injury to patients. To address this issue, we have successfully developed a prototype of a virtual reality haptic needle insertion simulator using the tactile feedback of 22 surgeons to set realistic haptic parameters. A survey of these surgeons concluded that our device appeared and felt realistic, and could potentially be a useful tool for teaching the proper technique of Veress needle insertion.

  18. First Materials Science Research Rack Capabilities and Design Features

    NASA Technical Reports Server (NTRS)

    Schaefer, D.; King, R.; Cobb, S.; Whitaker, Ann F. (Technical Monitor)

    2001-01-01

    The first Materials Science Research Rack (MSRR-1) will accommodate dual Experiment Modules (EM's) and provide simultaneous on-orbit processing operations capability. The first international Materials Science Experiment Module for the MSRR-1 is an international cooperative research activity between NASA's Marshall Space Flight Center (MSFC) and the European Space Agency's (ESA) European Space Research and Technology Center. (ESTEC). This International Standard Payload Rack (ISPR) will contain the Materials Science Laboratory (MSL) developed by ESA as an Experiment Module. The MSL Experiment Module will accommodate several on-orbit exchangeable experiment-specific Module Inserts. Module Inserts currently planned are a Quench Module Insert, Low Gradient Furnace, Solidification with Quench Furnace, and Diffusion Module Insert. The second Experiment Module for the MSRR-1 configuration is a commercial device supplied by MSFC's Space Products Department (SPD). It includes capabilities for vapor transport processes and liquid metal sintering. This Experiment Module will be replaced on-orbit with other NASA Materials Science EMs.

  19. Comparison of the analgesic effects of oral tramadol and naproxen sodium on pain relief during IUD insertion.

    PubMed

    Karabayirli, Safinaz; Ayrim, Aylin Aker; Muslu, Bunyamin

    2012-01-01

    To compare the analgesic efficacy of oral tramadol and naproxen sodium on pain during insertion of an intrauterine device (IUD). Randomized, double-blinded, clinical trial (Canadian Task Force classification I). University-affiliated hospital. Single-center. One hundred three patients scheduled for insertion of an IUD. Patients were randomly assigned to receive oral tramadol 50 mg capsules (n = 35) or naproxen sodium 550 mg tablets (n = 34) or placebo (n = 34) 1 hour before insertion of the IUD. After insertion of the IUD, pain intensity was evaluated using a visual analog scale (VAS, 0-10). Adverse effects, patient satisfaction with the medication, and preference for using it during future insertions were also recorded. The VAS scores were significantly different during IUD insertion among the 3 groups (p = .001). Pain scores in the tramadol group were significantly lower than in the naproxen group (p = .003), and the scores in the naproxen group was significantly lower than in the control group (p = .001). Patient satisfaction with the medication and preference for its future use were significantly lower in the control group than in the other 2 groups (p = .001). Prophylactic analgesia using 50 mg tramadol and 550 mg naproxen, delivered orally, can be used to relieve pain during IUD insertion. However, tramadol capsules were found to be more effective than naproxen tablets. Copyright © 2012 AAGL. Published by Elsevier Inc. All rights reserved.

  20. Ty1-copia elements reveal diverse insertion sites linked to polymorphisms among flax (Linum usitatissimum L.) accessions.

    PubMed

    Galindo-González, Leonardo; Mhiri, Corinne; Grandbastien, Marie-Angèle; Deyholos, Michael K

    2016-12-07

    Initial characterization of the flax genome showed that Ty1-copia retrotransposons are abundant, with several members being recently inserted, and in close association with genes. Recent insertions indicate a potential for ongoing transpositional activity that can create genomic diversity among accessions, cultivars or varieties. The polymorphisms generated constitute a good source of molecular markers that may be associated with phenotype if the insertions alter gene activity. Flax, where accessions are bred mainly for seed nutritional properties or for fibers, constitutes a good model for studying the relationship of transpositional activity with diversification and breeding. In this study, we estimated copy number and used a type of transposon display known as Sequence-Specific Amplification Polymorphisms (SSAPs), to characterize six families of Ty1-copia elements across 14 flax accessions. Polymorphic insertion sites were sequenced to find insertions that could potentially alter gene expression, and a preliminary test was performed with selected genes bearing transposable element (TE) insertions. Quantification of six families of Ty1-copia elements indicated different abundances among TE families and between flax accessions, which suggested diverse transpositional histories. SSAPs showed a high level of polymorphism in most of the evaluated retrotransposon families, with a trend towards higher levels of polymorphism in low-copy number families. Ty1-copia insertion polymorphisms among cultivars allowed a general distinction between oil and fiber types, and between spring and winter types, demonstrating their utility in diversity studies. Characterization of polymorphic insertions revealed an overwhelming association with genes, with insertions disrupting exons, introns or within 1 kb of coding regions. A preliminary test on the potential transcriptional disruption by TEs of four selected genes evaluated in three different tissues, showed one case of significant impact of the insertion on gene expression. We demonstrated that specific Ty1-copia families have been active since breeding commenced in flax. The retrotransposon-derived polymorphism can be used to separate flax types, and the close association of many insertions with genes defines a good source of potential mutations that could be associated with phenotypic changes, resulting in diversification processes.

  1. A multicenter randomized clinical trial of one-rod etonogestrel and two-rod levonorgestrel contraceptive implants with nonrandomized copper-IUD controls: methodology and insertion data.

    PubMed

    Meirik, Olav; Brache, Vivian; Orawan, Kiriwat; Habib, Ndema Abu; Schmidt, Johannes; Ortayli, Nuriye; Culwell, Kelly; Jackson, Emily; Ali, Moazzam

    2013-01-01

    Comparative data on etonogestrel and two-rod levonorgestrel contraceptive implants are lacking. A multicenter, open, parallel-group trial with random allocation of implants was performed. For every second implant user, an age-matched woman choosing an intrauterine device (IUD) (TCu380A) was admitted. Methods and data on implant/IUD insertion and 6-week follow-up are reported. A total of 2008 women were randomized to an implant, and 974 women were enrolled in the IUD group. Results from 997 etonogestrel implant users, 997 levonorgestrel implant users and 971 IUD users were analyzed. In the etonogestrel and levonorgestrel groups, respectively, mean insertion durations were 51 (SD 50.2) s and 88 (SD 60.8) s; complication rates at insertion were 0.8% and 0.2%; and at follow-up, 27.2% and 26.7% of women, respectively, had signs or symptoms at the insertion site. At follow-up within 6 weeks after insertion, all implants were in situ, while 2.1% of IUDs were expelled. Performance of etonogestrel and levonorgestrel implants at insertion and within the first 6 weeks is similar. Short-term (6 weeks) continuation rates appear higher for implants than TCu380A. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Design of a Tool Integrating Force Sensing With Automated Insertion in Cochlear Implantation

    PubMed Central

    Schurzig, Daniel; Labadie, Robert F.; Hussong, Andreas; Rau, Thomas S.; Webster, Robert J.

    2012-01-01

    The quality of hearing restored to a deaf patient by a cochlear implant in hearing preservation cochlear implant surgery (and possibly also in routine cochlear implant surgery) is believed to depend on preserving delicate cochlear membranes while accurately inserting an electrode array deep into the spiral cochlea. Membrane rupture forces, and possibly, other indicators of suboptimal placement, are below the threshold detectable by human hands, motivating a force sensing insertion tool. Furthermore, recent studies have shown significant variability in manual insertion forces and velocities that may explain some instances of imperfect placement. Toward addressing this, an automated insertion tool was recently developed by Hussong et al. By following the same insertion tool concept, in this paper, we present mechanical enhancements that improve the surgeon’s interface with the device and make it smaller and lighter. We also present electomechanical design of new components enabling integrated force sensing. The tool is designed to be sufficiently compact and light that it can be mounted to a microstereotactic frame for accurate image-guided preinsertion positioning. The new integrated force sensing system is capable of resolving forces as small as 0.005 N, and we provide experimental illustration of using forces to detect errors in electrode insertion. PMID:23482414

  3. Effect of dental wear, stabilization appliance and anterior tooth reconstruction on mandibular movements during speech.

    PubMed

    Serrano, Priscila de Oliveira; Faot, Fernanda; Del Bel Cury, Altair Antoninha; Rodrigues Garcia, Renata Cunha Matheus

    2008-01-01

    This study described changes in mandibular movements during pronunciation of /m/ and /s/ sounds in Portuguese, in patients presenting dental wear before and after appliance insertion and tooth reconstruction. Subjects were divided into a control group of dentate patients and an experimental group of patients with incisal tooth wear due to bruxism. A magnetic jaw tracking device measured the jaw opening, and translations to left and right sides of the mandible during pronunciation of phonemes. Evaluations were carried out 1 week and immediately before appliance insertion; 24 h, 7, 30 and 60 days after appliance insertion; and 1 week and 1 month after tooth reconstruction. Data were submitted to two-way ANOVA, Mann-Whitney and Friedman tests (p<0.05). Jaw opening was different (p<0.05) for both sounds in all periods. The anteroposterior amplitude for /s/ showed differences immediately before and 1 month after appliance insertion (p<0.05). Lateral amplitude for the right side showed differences between groups after appliance insertion for /s/, and 1 and 2 months after appliance insertion for the /m/ (p<0.05). Volunteers with anterior tooth wear had a wider opening movement, and the movements during speech of /m/ and /s/ sounds were not changed after appliance insertion and reconstruction of teeth.

  4. 42 CFR 410.36 - Medical supplies, appliances, and devices: Scope.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... eyeglasses or conventional contact lenses furnished after each cataract surgery during which an intraocular lens is inserted. (3) Leg, arm, back, and neck braces and artificial legs, arms, and eyes, including...

  5. 42 CFR 410.36 - Medical supplies, appliances, and devices: Scope.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... eyeglasses or conventional contact lenses furnished after each cataract surgery during which an intraocular lens is inserted. (3) Leg, arm, back, and neck braces and artificial legs, arms, and eyes, including...

  6. 31 CFR 1021.311 - Filing obligations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the same table game without leaving the table; (3) Bills inserted into electronic gaming devices in... would not apply); and (4) Jackpots from slot machines or video lottery terminals. [75 FR 65812, Oct. 26...

  7. 31 CFR 1021.311 - Filing obligations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the same table game without leaving the table; (3) Bills inserted into electronic gaming devices in... would not apply); and (4) Jackpots from slot machines or video lottery terminals. [75 FR 65812, Oct. 26...

  8. 31 CFR 1021.311 - Filing obligations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the same table game without leaving the table; (3) Bills inserted into electronic gaming devices in... would not apply); and (4) Jackpots from slot machines or video lottery terminals. [75 FR 65812, Oct. 26...

  9. Intracranial pressure monitoring (image)

    MedlinePlus

    Intracranial pressure monitoring is performed by inserting a catheter into the head with a sensing device to monitor the pressure around the brain. An increase in intracranial pressure can cause a decrease in blood flow to ...

  10. Healthcare Provider Attitudes of Safety of Intrauterine Devices in the Postpartum Period.

    PubMed

    Rauh-Benoit, Lisa A; Tepper, Naomi K; Zapata, Lauren B; Whiteman, Maura K; Curtis, Kathryn M; Mandel, Michele G; Marchbanks, Polly A; Jamieson, Denise J

    2017-07-01

    Immediate postpartum intrauterine devices (IUDs) have been underutilized in the United States despite their known safety. Understanding how providers' attitudes contribute to underutilization is important in improving access. Our objective was to examine healthcare providers' perceptions of the safety of immediate postpartum IUDs before publication of United States contraceptive guidelines. We analyzed survey data collected from December 2009 to March 2010 from 635 office-based physicians and 1368 Title X clinic providers (overall response rate of 64.8%). Providers were asked how safe they thought copper and levonorgestrel (LNG) IUDs were in postpartum women (very safe, safe, unsafe, very unsafe, and unsure). Multivariable logistic regression was used to calculate adjusted odds ratios (aORs) and 95% confidence intervals (95% CIs) for characteristics associated with considering immediate and delayed postpartum IUDs to be safe. Less than 40% of respondents considered immediate or delayed IUD insertion to be safe. Providers with <1 day of family planning training had decreased odds of considering immediate postpartum IUD insertion to be safe compared with unsafe/unsure (aOR 0.18, 95% CI 0.04-0.84 for copper IUD and aOR 0.17, 95% CI 0.04-0.81 for LNG-IUD). Providers without training in postpartum or interval copper IUD insertion had decreased odds of considering immediate postpartum copper IUD insertion (aOR 0.40, 95% CI 0.16-0.79) and delayed postpartum insertion for both IUD types to be safe (aOR 0.34, 95% CI 0.18-0.66 for copper IUD and aOR 0.41, 95% CI 0.21-0.77 for LNG-IUD). Before United States contraceptive guidelines, a majority of providers perceived immediate postpartum IUDs to be unsafe.

  11. Can intrauterine contraceptive devices lead to VulvoVaginal Candidiasis (VVC) and Anemia in Iranian new users?

    PubMed

    Behboudi-Gandevani, Samira; Imani, Somaieh; Moghaddam-Banaem, Lida; Roudbar-Mohammadi, Shahla

    2015-03-01

    To assess the prevalence of anemia and VulvoVaginal Candidiasis (VVC) in women before and 3 months after copper Intra Uterine Device (IUD) insertion. Longitudinal prospective study was performed with 101 women aged 15-45 year who wanted to use the IUD at six health centers in Tehran, Iran from November 2011 to August 2012. The pattern of bleeding, Hemoglobin and Hematocirt levels, and Candida colony count/cultures in the women were assessed before and after 3 months of IUD insertion. Data analysis was performed by descriptive and analytical statistics using the SPSS software for Windows. At the end of 3 months, a significant increase in menstrual blood loss and a significant decrease of Hb and HCT (P=0.047 and 0.001, respectively) were reported. Moreover, no difference in the prevalence of anemia before and after IUD insertion was observed. The mean±SD Candida colony counts significantly increased (P=0.001), but positive Candida cultures were not significantly different before and 3 months after IUD insertion. Also, no clinical VVC was reported 3 months after IUD insertion. While BMI≥29 had a positive relationship with Candida colony counts, the results remained unchanged after adjusting for potential risk factors. Despite an increase in bleeding and Candida colony counts in copper IUD users in this study, clinical VVC or anemia cases were not increased, which indicates relative safety of this contraception method. The study findings can be helpful to healthcare professionals and midwives to counsel women who want to start using IUD and also current users who are contemplating IUD removal due to its complications. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Multi-plug insole design to reduce peak plantar pressure on the diabetic foot during walking

    PubMed Central

    Actis, Ricardo L.; Ventura, Liliana B.; Lott, Donovan J.; Smith, Kirk E.; Commean, Paul K.; Hastings, Mary K.; Mueller, Michael J.

    2009-01-01

    There is evidence that appropriate footwear is an important factor in the prevention of foot pain in otherwise healthy people or foot ulcers in people with diabetes and peripheral neuropathy. A standard care for reducing forefoot plantar pressure is the utilization of orthotic devices such as total contact inserts (TCI) with therapeutic footwear. Most neuropathic ulcers occur under the metatarsal heads, and foot deformity combined with high localized plantar pressure, appear to be the most significant factors contributing to these ulcers. In this study, patient-specific finite element models of the second ray of the foot were developed to study the influence of TCI design on peak plantar pressure (PPP) under the metatarsal heads. A typical full contact insert was modified based on the results of finite element analyses, by inserting 4 mm diameter cylindrical plugs of softer material in the regions of high pressure. Validation of the numerical model was addressed by comparing the numerical results obtained by the finite element method with measured pressure distribution in the region of the metatarsal heads for a shoe and TCI condition. Two subjects, one with a history of forefoot pain and one with diabetes and peripheral neuropathy, were tested in the laboratory while wearing therapeutic shoes and customized inserts. The study showed that customized inserts with softer plugs distributed throughout the regions of high plantar pressure reduced the PPP over that of the TCI alone. This supports the outcome as predicted by the numerical model, without causing edge effects as reported by other investigators using different plug designs, and provides a greater degree of flexibility for customizing orthotic devices than current practice allows. PMID:18266017

  13. Multi-plug insole design to reduce peak plantar pressure on the diabetic foot during walking.

    PubMed

    Actis, Ricardo L; Ventura, Liliana B; Lott, Donovan J; Smith, Kirk E; Commean, Paul K; Hastings, Mary K; Mueller, Michael J

    2008-04-01

    There is evidence that appropriate footwear is an important factor in the prevention of foot pain in otherwise healthy people or foot ulcers in people with diabetes and peripheral neuropathy. A standard care for reducing forefoot plantar pressure is the utilization of orthotic devices such as total contact inserts (TCI) with therapeutic footwear. Most neuropathic ulcers occur under the metatarsal heads, and foot deformity combined with high localized plantar pressure, appear to be the most significant factors contributing to these ulcers. In this study, patient-specific finite element models of the second ray of the foot were developed to study the influence of TCI design on peak plantar pressure (PPP) under the metatarsal heads. A typical full contact insert was modified based on the results of finite element analyses, by inserting 4 mm diameter cylindrical plugs of softer material in the regions of high pressure. Validation of the numerical model was addressed by comparing the numerical results obtained by the finite element method with measured pressure distribution in the region of the metatarsal heads for a shoe and TCI condition. Two subjects, one with a history of forefoot pain and one with diabetes and peripheral neuropathy, were tested in the laboratory while wearing therapeutic shoes and customized inserts. The study showed that customized inserts with softer plugs distributed throughout the regions of high plantar pressure reduced the PPP over that of the TCI alone. This supports the outcome as predicted by the numerical model, without causing edge effects as reported by other investigators using different plug designs, and provides a greater degree of flexibility for customizing orthotic devices than current practice allows.

  14. The effect of intermittent use of occlusal splint devices on sleep bruxism: a 4-week observation with a portable electromyographic recording device.

    PubMed

    Matsumoto, H; Tsukiyama, Y; Kuwatsuru, R; Koyano, K

    2015-04-01

    This randomised controlled study investigated the effect of intermittent use of occlusal splints on sleep bruxism compared with that of continuous use by measuring masseter muscle electromyographic activity using a portable electromyographic recording system. Twenty bruxers were randomly allocated to the continuous group and intermittent group. Subjects in the continuous group wore stabilisation splints during sleep for 29 nights continuously, whereas those in the intermittent group wore splints during sleep every other week, that is they used splints on the 1st-7th, 15th-21st and 29th nights. Electromyographic activity of the masseter muscle during sleep was recorded for the following six time points: before (baseline), immediately after, and 1, 2, 3 and 4 weeks after the insertion of a stabilisation splint. The number of nocturnal masseter electromyographic events, duration and the total activity of sleep bruxism were analysed. In the continuous group, nocturnal masseter electromyographic events were significantly reduced immediately and 1 week after the insertion of the stabilisation splint, and duration was reduced immediately after the insertion (P < 0·05, Dunnett's test), but no reduction was observed at 2, 3 and 4 weeks after insertion. In the intermittent group, nocturnal masseter electromyographic events and duration were significantly reduced immediately after and also 4 weeks after insertion of the stabilisation splint (P < 0·05, Dunnett's test). The obtained results of the present exploratory trial indicate that the intermittent use of stabilisation splints may reduce sleep bruxism activity for a longer period compared with that of continuous use. © 2014 John Wiley & Sons Ltd.

  15. Intrauterine contraception in nulliparous women: a prospective survey.

    PubMed

    Hall, Alexandra M; Kutler, Beth A

    2016-01-01

    Intrauterine contraception is a first-line option for young women, yet relatively few prospective studies have been performed in nulliparous women using currently available devices, and many providers are still reluctant to provide this option. Between January 2012 and June 2014, 109 nulliparous women, aged 18-30 years, who had an intrauterine device (IUD) placed at a student health clinic [88 levonorgestrel-intrauterine system (LNG-IUS) users and 21 Cu T 380A (IUD) users] were surveyed at 1, 6, 12 and 18 months after insertion. Overall satisfaction was high; at follow-up survey 83% of 100 women (mean use 13.4 months) were 'happy' or 'very happy' with their IUD, and there were no differences in satisfaction between the two IUD types. Some 75% of participants stated that the insertion procedure went 'very well', despite 78% rating insertion pain as moderate to severe, and 46% experiencing vasovagal symptoms. The 12-month continuation rate was 89%, with discontinuations for expulsion (3%), side effects (6%), lack of anticipated benefit (1%) and pregnancy (1%). Users of the Cu T 380A were more likely to have heavy menses (74% vs 2%; p<0.0001) or moderate to severe cramping (68% vs 20%; p=0.0002) compared with LNG-IUS users. There were no uterine perforations or diagnoses of pelvic inflammatory disease. The rate of failed insertions during the study period was 6.2%. Despite significant symptoms with insertion, intrauterine contraception is safe, effective and ultimately well tolerated in nulliparous women and should be provided to this population in both university and community health settings. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  16. A randomised controlled trial comparing ProSeal laryngeal mask airway, i-gel and Laryngeal Tube Suction-D under general anaesthesia for elective surgical patients requiring controlled ventilation.

    PubMed

    Das, Bikramjit; Varshney, Rahul; Mitra, Subhro

    2017-12-01

    The ProSeal™ laryngeal mask airway (PLMA), i-gel™ and Laryngeal Tube Suction-D (LTS-D™) have previously been evaluated alone or in pair-wise comparisons but differing study designs make it difficult to compare the results. The aim of this study was to compare the clinical performance of these three devices in terms of efficacy and safety in patients receiving mechanical ventilation during elective surgical procedures. This prospective, randomised, double-blind study was conducted on 150 American Society of Anesthesiologists physical status I-II patients, randomly allocated into 3 groups, undergoing elective surgical procedures under general anaesthesia. PLMA, i-gel™ or LTS-D™ appropriate for weight or/and height was inserted. Primary outcome measured was airway sealing pressure. Insertion time, ease of insertion, number of attempts, overall success rate and the incidence of airway trauma and complications were also recorded. Intergroup differences were compared using one-way analysis of variance with post hoc correction for continuous data and Chi-square test for categorical variables. Overall success rate was comparable between the three devices (i-gel™ 100%, LTS-D™ 94%, PLMA 96%). Airway sealing pressure was lower with i-gel™ (23.38 ± 2.06 cm H 2 O) compared to LTS-D™ (26.06 ± 2.11 cm H 2 O) and PLMA (28.5 ± 2.8 cm H 2 O; P < 0.0005). The mean insertion time was significantly more in PLMA (38.77 ± 3.2 s) compared to i-gel™ (27.9 ± 2.53 s) and LTS-D™ (21.66 ± 2.31 s; P < 0.0005). Airway sealing pressure and insertion time were significantly higher in PLMA compared to i-gel™ and LTS-D™.

  17. Evaluation of the efficacy of six supraglottic devices for airway management in dark conditions: a crossover randomized simulation trial.

    PubMed

    Ohchi, Fumihiro; Komasawa, Nobuyasu; Imagawa, Kentaro; Okamoto, Kaori; Minami, Toshiaki

    2015-12-01

    During out-of-hospital cardiopulmonary resuscitation, several factors can render tracheal intubation more difficult, such as when rescuers must secure the airway in complete darkness or with limited illumination. The purpose of this study was to evaluate the efficacy of six supraglottic devices (SGDs), ProSeal(®) (ProSeal), Classic(®) (Classic), Supreme(®) (Supreme), Laryngeal Tube(®) (LT), air-Q(®) (air-Q), and i-gel(®) (i-gel), for airway management under light and dark conditions using a manikin. Seventeen novice doctors and 15 experienced doctors performed insertion of six SGDs under light and dark conditions using an adult manikin. Insertion time, successful ventilation rate, and subjective insertion difficulty on a visual analogue scale (VAS) were measured. Both novice and experienced doctors had a significantly lower ventilation success rate in the dark than in the light when ProSeal and Classic were used, but not with the other four SGDs. Novice doctors required a significantly longer insertion time in the dark than in the light with all SGDs. Experienced doctors required a significantly longer insertion time in the dark than in the light with ProSeal or Classic, but not with the other four SGDs. VAS was significantly higher for both novice and experienced doctors when ProSeal and Classic were used, as compared with the other four SGDs in the dark. Compared to ProSeal and Classic, Supreme, i-gel, LT, and air-Q are more effective for airway management in the dark. Our findings suggest that anatomically shaped SGDs may help novice doctors secure the airway under dark conditions.

  18. Intrauterine contraception in nulliparous women: a prospective survey

    PubMed Central

    Kutler, Beth A

    2016-01-01

    Background Intrauterine contraception is a first-line option for young women, yet relatively few prospective studies have been performed in nulliparous women using currently available devices, and many providers are still reluctant to provide this option. Methods Between January 2012 and June 2014, 109 nulliparous women, aged 18–30 years, who had an intrauterine device (IUD) placed at a student health clinic [88 levonorgestrel-intrauterine system (LNG-IUS) users and 21 Cu T 380A (IUD) users] were surveyed at 1, 6, 12 and 18 months after insertion. Results Overall satisfaction was high; at follow-up survey 83% of 100 women (mean use 13.4 months) were ‘happy’ or ‘very happy’ with their IUD, and there were no differences in satisfaction between the two IUD types. Some 75% of participants stated that the insertion procedure went ‘very well’, despite 78% rating insertion pain as moderate to severe, and 46% experiencing vasovagal symptoms. The 12-month continuation rate was 89%, with discontinuations for expulsion (3%), side effects (6%), lack of anticipated benefit (1%) and pregnancy (1%). Users of the Cu T 380A were more likely to have heavy menses (74% vs 2%; p<0.0001) or moderate to severe cramping (68% vs 20%; p=0.0002) compared with LNG-IUS users. There were no uterine perforations or diagnoses of pelvic inflammatory disease. The rate of failed insertions during the study period was 6.2%. Conclusions Despite significant symptoms with insertion, intrauterine contraception is safe, effective and ultimately well tolerated in nulliparous women and should be provided to this population in both university and community health settings. PMID:25854550

  19. Mission Advantages of Constant Power, Variable Isp Electrostatic Thrusters

    NASA Technical Reports Server (NTRS)

    Oleson, Steven R.

    2000-01-01

    Electric propulsion has moved from station-keeping capability for spacecraft to primary propulsion with the advent of both the Deep Space One asteroid flyby and geosynchronous spacecraft orbit insertion. In both cases notably more payload was delivered than would have been possible with chemical propulsion. To provide even greater improvements electrostatic thruster performance could be varied in specific impulse, but kept at constant power to provide better payload or trip time performance for different mission phases. Such variable specific impulse mission applications include geosynchronous and low earth orbit spacecraft stationkeeping and orbit insertion, geosynchronous reusable tug missions, and interplanetary probes. The application of variable specific impulse devices is shown to add from 5 to 15% payload for these missions. The challenges to building such devices include variable voltage power supplies and extending fuel throughput capabilities across the specific impulse range.

  20. Development of a new technique for pedicle screw and Magerl screw insertion using a 3-dimensional image guide.

    PubMed

    Kawaguchi, Yoshiharu; Nakano, Masato; Yasuda, Taketoshi; Seki, Shoji; Hori, Takeshi; Kimura, Tomoatsu

    2012-11-01

    We developed a new technique for cervical pedicle screw and Magerl screw insertion using a 3-dimensional image guide. In posterior cervical spinal fusion surgery, instrumentation with screws is virtually routine. However, malpositioning of screws is not rare. To avoid complications during cervical pedicle screw and Magerl screw insertion, the authors developed a new technique which is a mold shaped to fit the lamina. Cervical pedicle screw fixation and Magerl screw fixation provide good correction of cervical alignment, rigid fixation, and a high fusion rate. However, malpositioning of screws is not a rare occurrence, and thus the insertion of screws has a potential risk of neurovascular injury. It is necessary to determine a safe insertion procedure for these screws. Preoperative computed tomographic (CT) scans of 1-mm slice thickness were obtained of the whole surgical area. The CT data were imported into a computer navigation system. We developed a 3-dimensional full-scale model of the patient's spine using a rapid prototyping technique from the CT data. Molds of the left and right sides at each vertebra were also constructed. One hole (2.0 mm in diameter and 2.0 cm in length) was made in each mold for the insertion of a screw guide. We performed a simulated surgery using the bone model and the mold before operation in all patients. The mold was firmly attached to the surface of the lamina and the guide wire was inserted using the intraoperative image of lateral vertebra. The proper insertion point, direction, and length of the guide were also confirmed both with the model bone and the image intensifier in the operative field. Then, drilling using a cannulated drill and tapping using a cannulated tapping device were carried out. Eleven consecutive patients who underwent posterior spinal fusion surgery using this technique since 2009 are included. The screw positions in the sagittal and axial planes were evaluated by postoperative CT scan to check for malpositioning. The screw insertion was done in the same manner as the simulated surgery. With the aid of this guide the pedicle screws and Magerl screws could be easily inserted even at the level where the pedicle seemed to be very thin and sclerotic on the CT scan. Postoperative CT scan showed that there were no critical breaches of the screws. This method employing the device using a 3-dimensional image guide seems to be easy and safe to use. The technique may improve the safety of pedicle screw and Magerl screw insertion even in difficult cases with narrow sclerotic pedicles.

  1. High aspect ratio catalytic reactor and catalyst inserts therefor

    DOEpatents

    Lin, Jiefeng; Kelly, Sean M.

    2018-04-10

    The present invention relates to high efficient tubular catalytic steam reforming reactor configured from about 0.2 inch to about 2 inch inside diameter high temperature metal alloy tube or pipe and loaded with a plurality of rolled catalyst inserts comprising metallic monoliths. The catalyst insert substrate is formed from a single metal foil without a central supporting structure in the form of a spiral monolith. The single metal foil is treated to have 3-dimensional surface features that provide mechanical support and establish open gas channels between each of the rolled layers. This unique geometry accelerates gas mixing and heat transfer and provides a high catalytic active surface area. The small diameter, high aspect ratio tubular catalytic steam reforming reactors loaded with rolled catalyst inserts can be arranged in a multi-pass non-vertical parallel configuration thermally coupled with a heat source to carry out steam reforming of hydrocarbon-containing feeds. The rolled catalyst inserts are self-supported on the reactor wall and enable efficient heat transfer from the reactor wall to the reactor interior, and lower pressure drop than known particulate catalysts. The heat source can be oxygen transport membrane reactors.

  2. Permanent magnet edge-field quadrupole

    DOEpatents

    Tatchyn, R.O.

    1997-01-21

    Planar permanent magnet edge-field quadrupoles for use in particle accelerating machines and in insertion devices designed to generate spontaneous or coherent radiation from moving charged particles are disclosed. The invention comprises four magnetized rectangular pieces of permanent magnet material with substantially similar dimensions arranged into two planar arrays situated to generate a field with a substantially dominant quadrupole component in regions close to the device axis. 10 figs.

  3. Permanent magnet edge-field quadrupole

    DOEpatents

    Tatchyn, Roman O.

    1997-01-01

    Planar permanent magnet edge-field quadrupoles for use in particle accelerating machines and in insertion devices designed to generate spontaneous or coherent radiation from moving charged particles are disclosed. The invention comprises four magnetized rectangular pieces of permanent magnet material with substantially similar dimensions arranged into two planar arrays situated to generate a field with a substantially dominant quadrupole component in regions close to the device axis.

  4. Microwave fiber optics delay line

    NASA Astrophysics Data System (ADS)

    Slayman, C.; Yen, H. W.

    1980-01-01

    A microwave delay line is one of the devices used in EW systems for preserving the frequency and phase contents of RF signals. For such applications, delay lines are required to have large dynamic range, wide bandwidth, low insertion loss, and a linear response. The basic components of a fiber-optics delay line are: an optical source, a wideband optical modulator, a spool of single-mode fiber with appropriate length to provide a given microwave signal delay, and a high-speed photodetector with an RF amplifier. This contract program is to study the feasibility of such a fiber-optic delay line in the frequency range of 4.0 to 6.5 GHz. The modulation scheme studied is the direct modulation of injection lasers. The most important issue identified is the frequency response of the injection laser and the photodetector.

  5. UNDULATOR-BASED LASER WAKEFIELD ACCELERATOR ELECTRON BEAM DIAGNOSTIC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bakeman, M.S.; Fawley, W.M.; Leemans, W. P.

    to couple the THUNDER undulator to the LOASIS Lawrence Berkeley National Laboratory (LBNL) laser wakefield accelerator (LWFA). Currently the LWFA has achieved quasi-monoenergetic electron beams with energies up to 1 GeV. These ultra-short, high-peak-current, electron beams are ideal for driving a compact XUV free electron laser (FEL). Understanding the electron beam properties such as the energy spread and emittance is critical for achieving high quality light sources with high brightness. By using an insertion device such as an undulator and observing changes in the spontaneous emission spectrum, the electron beam energy spread and emittance can be measured with high precision.more » The initial experiments will use spontaneous emission from 1.5 m of undulator. Later experiments will use up to 5 m of undulator with a goal of a high gain, XUV FEL.« less

  6. FEM Modeling of a Magnetoelectric Transducer for Autonomous Micro Sensors in Medical Application

    NASA Astrophysics Data System (ADS)

    Yang, Gang; Talleb, Hakeim; Gensbittel, Aurélie; Ren, Zhuoxiang

    2015-11-01

    In the context of wireless and autonomous sensors, this paper presents the multiphysics modeling of an energy transducer based on magnetoelectric (ME) composite for biomedical applications. The study considers the power requirement of an implanted sensor, the communication distance, the size limit of the device for minimal invasive insertion as well as the electromagnetic exposure restriction of the human body. To minimize the electromagnetic absorption by the human body, the energy source is provided by an external reader emitting low frequency magnetic field. The modeling is carried out with the finite element method by solving simultaneously the multiple physics problems including the electric load of the conditioning circuit. The simulation results show that with the T-L mode of a trilayer laminated ME composite, the transducer can deliver the required energy in respecting different constraints.

  7. Relative device stability of anterior versus axillary needle decompression for tension pneumothorax during casualty movement: Preliminary analysis of a human cadaver model.

    PubMed

    Leatherman, Matthew L; Held, Jenny M; Fluke, Laura M; McEvoy, Christian S; Inaba, Kenji; Grabo, Daniel; Martin, Matthew J; Earley, Angela S; Ricca, Robert L; Polk, Travis M

    2017-07-01

    Tension pneumothorax (tPTX) remains a significant cause of potentially preventable death in military and civilian settings. The current prehospital standard of care for tPTX is immediate decompression with a 14-gauge 8-cm angiocatheter; however, failure rates may be as high as 17% to 60%. Alternative devices, such as 10-gauge angiocatheter, modified Veress needle, and laparoscopic trocar, have shown to be potentially more effective in animal models; however, little is known about the relative insertional safety or mechanical stability during casualty movement. Seven soft-embalmed cadavers were intubated and mechanically ventilated. Chest wall thickness was measured at the second intercostal space at the midclavicular line (2MCL) and the fifth intercostal space along the anterior axillary line (5AAL). CO2 insufflation created a PTX, and needle decompression was then performed with a randomized device. Insertional depth was measured between hub and skin before and after simulated casualty transport. Thoracoscopy was used to evaluate for intrapleural placement and/or injury during insertion and after movement. Cadaver demographics, device displacement, device dislodgment, and injuries were recorded. Three decompressions were performed at each site (2MCL/5AAL), totaling 12 events per cadaver. Eighty-four decompressions were performed. Average cadaver age was 59 years, and body mass index was 24 kg/m. The CWT varied between cadavers because of subcutaneous emphysema, but the average was 39 mm at the 2MCL and 31 mm at the 5AAL. Following movement, the 2MCL site was more likely to become dislodged than the 5AAL (67% vs. 17%, p = 0.001). Median displacement also differed between 2MCL and 5AAL (23 vs. 2 mm, p = 0.001). No significant differences were noted in dislodgement or displacement between devices. Five minor lung injuries were noted at the 5AAL position. Preliminary results from this human cadaver study suggest the 5AAL position is a more stable and reliable location for thoracic decompression of tPTX during combat casualty transport. Therapeutic study, level III.

  8. CALIS—A CALibration Insertion System for the DarkSide-50 dark matter search experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agnes, P.; Albuquerque, I. F. M.; Alexander, T.

    This paper describes the design, fabrication, commissioning and use of a CALibration source Insertion System (CALIS) in the DarkSide-50 direct dark matter search experiment. CALIS deploys radioactive sources into the liquid scintillator veto to characterize the detector response and detection efficiency of the DarkSide-50 Liquid Argon Time Projection Chamber, and the surrounding 30 t organic liquid scintillator neutron veto. It was commissioned in September 2014 and has been used successfully in several gamma and neutron source campaigns since then. A description of the hardware and an excerpt of calibration analysis results are given below.

  9. CALIS—A CALibration Insertion System for the DarkSide-50 dark matter search experiment

    NASA Astrophysics Data System (ADS)

    Agnes, P.; Albuquerque, I. F. M.; Alexander, T.; Alton, A. K.; Asner, D. M.; Back, H. O.; Baldin, B.; Biery, K.; Bocci, V.; Bonfini, G.; Bonivento, W.; Bossa, M.; Bottino, B.; Brigatti, A.; Brodsky, J.; Budano, F.; Bussino, S.; Cadeddu, M.; Cadonati, L.; Cadoni, M.; Calaprice, F.; Canci, N.; Candela, A.; Caravati, M.; Cariello, M.; Carlini, M.; Catalanotti, S.; Cavalcante, P.; Chepurnov, A.; Cicalò, C.; Cocco, A. G.; Covone, G.; D'Angelo, D.; D'Incecco, M.; Davini, S.; De Cecco, S.; De Deo, M.; De Vincenzi, M.; Derbin, A.; Devoto, A.; Di Eusanio, F.; Di Pietro, G.; Dionisi, C.; Edkins, E.; Empl, A.; Fan, A.; Fiorillo, G.; Fomenko, K.; Forster, G.; Franco, D.; Gabriele, F.; Galbiati, C.; Giagu, S.; Giganti, C.; Giovanetti, G. K.; Goretti, A. M.; Granato, F.; Grandi, L.; Gromov, M.; Guan, M.; Guardincerri, Y.; Hackett, B. R.; Herner, K.; Hughes, D.; Humble, P.; Hungerford, E. V.; Ianni, Al.; Ianni, An.; James, I.; Johnson, T. N.; Jollet, C.; Keeter, K.; Kendziora, C. L.; Koh, G.; Korablev, D.; Korga, G.; Kubankin, A.; Li, X.; Lissia, M.; Loer, B.; Lombardi, P.; Longo, G.; Ma, Y.; Machado, A. A.; Machulin, I. N.; Mandarano, A.; Mari, S. M.; Maricic, J.; Marini, L.; Martoff, C. J.; Meregaglia, A.; Meyers, P. D.; Milincic, R.; Miller, J. D.; Montanari, D.; Monte, A.; Mount, B. J.; Muratova, V. N.; Musico, P.; Napolitano, J.; Navrer Agasson, A.; Odrowski, S.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Pantic, E.; Parmeggiano, S.; Pelczar, K.; Pelliccia, N.; Pocar, A.; Pordes, S.; Pugachev, D. A.; Qian, H.; Randle, K.; Ranucci, G.; Razeti, M.; Razeto, A.; Reinhold, B.; Renshaw, A. L.; Rescigno, M.; Riffard, Q.; Romani, A.; Rossi, B.; Rossi, N.; Rountree, D.; Sablone, D.; Saggese, P.; Saldanha, R.; Sands, W.; Savarese, C.; Schlitzer, B.; Segreto, E.; Semenov, D. A.; Shields, E.; Singh, P. N.; Skorokhvatov, M. D.; Smirnov, O.; Sotnikov, A.; Stanford, C.; Suvorov, Y.; Tartaglia, R.; Tatarowicz, J.; Testera, G.; Tonazzo, A.; Trinchese, P.; Unzhakov, E. V.; Verducci, M.; Vishneva, A.; Vogelaar, B.; Wada, M.; Walker, S.; Wang, H.; Wang, Y.; Watson, A. W.; Westerdale, S.; Wilhelmi, J.; Wojcik, M. M.; Xiang, Xi.; Xiao, X.; Xu, J.; Yang, C.; Zec, A.; Zhong, W.; Zhu, C.; Zuzel, G.

    2017-12-01

    This paper describes the design, fabrication, commissioning and use of a CALibration source Insertion System (CALIS) in the DarkSide-50 direct dark matter search experiment. CALIS deploys radioactive sources into the liquid scintillator veto to characterize the detector response and detection efficiency of the DarkSide-50 Liquid Argon Time Projection Chamber, and the surrounding 30 t organic liquid scintillator neutron veto. It was commissioned in September 2014 and has been used successfully in several gamma and neutron source campaigns since then. A description of the hardware and an excerpt of calibration analysis results are given below.

  10. CALIS—A CALibration Insertion System for the DarkSide-50 dark matter search experiment

    DOE PAGES

    Agnes, P.; Albuquerque, I. F. M.; Alexander, T.; ...

    2017-12-18

    This paper describes the design, fabrication, commissioning and use of a CALibration source Insertion System (CALIS) in the DarkSide-50 direct dark matter search experiment. CALIS deploys radioactive sources into the liquid scintillator veto to characterize the detector response and detection efficiency of the DarkSide-50 Liquid Argon Time Projection Chamber, and the surrounding 30 t organic liquid scintillator neutron veto. It was commissioned in September 2014 and has been used successfully in several gamma and neutron source campaigns since then. A description of the hardware and an excerpt of calibration analysis results are given below.

  11. Electrical apparatus lockout device

    DOEpatents

    Gonzales, Rick

    1999-01-01

    A simple lockout device for electrical equipment equipped with recessed power blades is described. The device comprises a face-plate (12) having a threaded member (14) attached thereto and apertures suitable for accommodating the power blades of a piece of electrical equipment, an elastomeric nose (16) abutting the face-plate having a hole for passage of the threaded member therethrough and power blade apertures in registration with those of the face-plate, a block (20) having a recess (34) in its forward face for receiving at least a portion of the hose, a hole therein for receiving the threaded member and an integral extension (26) extending from its rear face. A thumb screw (22) suitable for turning with the hands and having internal threads suitable for engaging the threaded member attached to the face-plate is inserted into a passage in the integral extension to engage the threaded member in such a fashion that when the device is inserted over the recessed power blades of a piece of electrical equipment and the thumb screw (22) tightened, the elastomeric nose (16) is compressed between the face-plate (12) and the block (20) forcing it to expand laterally thereby securing the device in the recess and precluding the accidental or intentional energization of the piece of equipment by attachment of a power cord to the recessed power blades. Means are provided in the interval extension and the thumb screw for the attachment of a locking device (46) which will satisfy OSHA standards.

  12. Development of a Robotic Colonoscopic Manipulation System, Using Haptic Feedback Algorithm.

    PubMed

    Woo, Jaehong; Choi, Jae Hyuk; Seo, Jong Tae; Kim, Tae Il; Yi, Byung Ju

    2017-01-01

    Colonoscopy is one of the most effective diagnostic and therapeutic tools for colorectal diseases. We aim to propose a master-slave robotic colonoscopy that is controllable in remote site using conventional colonoscopy. The master and slave robot were developed to use conventional flexible colonoscopy. The robotic colonoscopic procedure was performed using a colonoscope training model by one expert endoscopist and two unexperienced engineers. To provide the haptic sensation, the insertion force and the rotating torque were measured and sent to the master robot. A slave robot was developed to hold the colonoscopy and its knob, and perform insertion, rotation, and two tilting motions of colonoscope. A master robot was designed to teach motions of the slave robot. These measured force and torque were scaled down by one tenth to provide the operator with some reflection force and torque at the haptic device. The haptic sensation and feedback system was successful and helpful to feel the constrained force or torque in colon. The insertion time using robotic system decreased with repeated procedures. This work proposed a robotic approach for colonoscopy using haptic feedback algorithm, and this robotic device would effectively perform colonoscopy with reduced burden and comparable safety for patients in remote site.

  13. A simple method to accurately position Port-A-Cath without the aid of intraoperative fluoroscopy or other localizing devices.

    PubMed

    Horng, Huann-Cheng; Yuan, Chiou-Chung; Chao, Kuan-Chong; Cheng, Ming-Huei; Wang, Peng-Hui

    2007-06-01

    To evaluate the efficacy and acceptability of the Port-A-Cath (PAC) insertion method with (conventional group as II) and without (modified group as I) the aid of intraoperative fluoroscopy or other localizing devices. A total of 158 women with various kinds of gynecological cancers warranting PAC insertion (n = 86 in group I and n = 72 in group II, respectively) were evaluated. Data for analyses included patient age, main disease, dislocation site, surgical time, complications, and catheter outcome. There was no statistical difference between the two groups in terms of age, main disease, complications, and the experiencing of patent catheters. However, appropriate positioning (100% in group I, and 82% in group II) in the superior vena cava (SVC) showed statistical differences between the two groups (P = 0.001). In addition, the surgical time in group I was statistically shorter than that in group II (P < 0.001). The modified method for inserting the PAC offered the following benefits: including avoiding X-ray exposure for both the operator and the patient, defining the appropriate position in the SVC, and less surgical time. (c) 2007 Wiley-Liss, Inc.

  14. Use of SIG device to accurately place permanent miniature dental implants to retain mandibular overdenture. A case report.

    PubMed

    Sussman, Harold I; Goodridge, Opal F

    2006-01-01

    A case of mini-dental implant insertion for retention of a mandibular overdenture in a hospitalized patient has been documented. The additional use of the SIG (drill guide) directional device in the implant placement protocol gave the practitioner more confidence and resulted in the proper alignment of the three ball-top, one-piece fixtures. The three implants were inserted exactly 1 cm apart and parallel to each other. The distal fixtures were approximately 1 cm away from the mental foramina, thereby eliminating the risk of lip paresthesia. Keeper caps were placed in the denture's intaglio after one month. The keeper caps allowed for proper retention of the overdenture. The caps also enabled the patient to easily insert and withdraw his denture, even though he displayed limited manual dexterity. The tissue response was excellent, and oral hygiene was made easier with adequate spacing of the exposed ball-tops. The overall experience for both the operator and the patient was very positive. General dentists should be able to readily master this technique and add it to their armamentarium for the benefit of all their patients.

  15. Microwave evaluation of electromigration susceptibility in advanced interconnects.

    PubMed

    Sunday, Christopher E; Veksler, Dmitry; Cheung, Kin C; Obeng, Yaw S

    2017-11-07

    Traditional metrology has been unable to adequately address the needs of the emerging integrated circuits (ICs) at the nano scale; thus, new metrology and techniques are needed. For example, the reliability challenges in fabrication need to be well understood and controlled to facilitate mass production of through-substrate-via (TSV) enabled three-dimensional integrated circuits (3D-ICs). This requires new approaches to the metrology. In this paper, we use the microwave propagation characteristics to study the reliability issues that precede the physical damage caused by electromigration in the Cu-filled TSVs. The pre-failure microwave insertion losses and group delay are dependent on both the device temperature and the amount of current forced through the devices-under-test. The microwave insertion losses increase with the increase in the test temperature, while the group delay increases with the increase in the forced direct current magnitude. The microwave insertion losses are attributed to the defect mobility at the Cu-TiN interface, and the group delay changes are due to resistive heating in the interconnects, which perturbs the dielectric properties of the cladding dielectrics of the copper fill in the TSVs. https://doi.org/10.1063/1.4992135.

  16. 48 CFR 52.222-50 - Combating Trafficking in Persons.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ....222-50 Combating Trafficking in Persons. As prescribed in 22.1705(a), insert the following clause...: ________ ________ ________ ________ ________ ________ [Contracting Officer shall insert title of directive/notice; indicate the document is attached or provide source (such as website link) for obtaining document; and, indicate the contract performance location...

  17. The accuracy and the safety of individualized 3D printing screws insertion templates for cervical screw insertion.

    PubMed

    Deng, Ting; Jiang, Minghui; Lei, Qing; Cai, Lihong; Chen, Li

    2016-12-01

    Clinical trial for cervical screw insertion by using individualized 3-dimensional (3D) printing screw insertion templates device. The objective of this study is to evaluate the safety and accuracy of the individualized 3D printing screw insertion template in the cervical spine. Ten patients who underwent posterior cervical fusion surgery with cervical pedicle screws, laminar screws or lateral mass screws between December 2014 and December 2015 were involved in this study. The patients were examined by CT scan before operation. The individualized 3D printing templates were made with photosensitive resin by a 3D printing system to ensure the screw shafts entered the vertebral body without breaking the pedicle or lamina cortex. The templates were sterilized by a plasma sterilizer and used during the operation. The accuracy and the safety of the templates were evaluated by CT scans at the screw insertion levels after operation. The accuracy of this patient-specific template technique was demonstrated. Only one screw axis greatly deviated from the planned track and breached the cortex of the pedicle because the template was split by rough handling and then we inserted the screws under the fluoroscopy. The remaining screws were inserted in the track as preoperative design and the screw axis deviated by less than 2 mm. Vascular or neurologic complications or injuries did not happen. And no infection, broken nails, fracture of bone structure, or screw pullout occurred. This study verified the safety and the accuracy of the individualized 3D printing screw insertion templates in the cervical spine as a kind of intraoperative screw navigation. This individualized 3D printing screw insertion template was user-friendly, moderate cost, and enabled a radiation-free cervical screw insertion.

  18. Mitochondrial DNA transfer to the nucleus generates extensive insertion site variation in maize.

    PubMed

    Lough, Ashley N; Roark, Leah M; Kato, Akio; Ream, Thomas S; Lamb, Jonathan C; Birchler, James A; Newton, Kathleen J

    2008-01-01

    Mitochondrial DNA (mtDNA) insertions into nuclear chromosomes have been documented in a number of eukaryotes. We used fluorescence in situ hybridization (FISH) to examine the variation of mtDNA insertions in maize. Twenty overlapping cosmids, representing the 570-kb maize mitochondrial genome, were individually labeled and hybridized to root tip metaphase chromosomes from the B73 inbred line. A minimum of 15 mtDNA insertion sites on nine chromosomes were detectable using this method. One site near the centromere on chromosome arm 9L was identified by a majority of the cosmids. To examine variation in nuclear mitochondrial DNA sequences (NUMTs), a mixture of labeled cosmids was applied to chromosome spreads of ten diverse inbred lines: A188, A632, B37, B73, BMS, KYS, Mo17, Oh43, W22, and W23. The number of detectable NUMTs varied dramatically among the lines. None of the tested inbred lines other than B73 showed the strong hybridization signal on 9L, suggesting that there is a recent mtDNA insertion at this site in B73. Different sources of B73 and W23 were examined for NUMT variation within inbred lines. Differences were detectable, suggesting either that mtDNA is being incorporated or lost from the maize nuclear genome continuously. The results indicate that mtDNA insertions represent a major source of nuclear chromosomal variation.

  19. Wavefront propagation simulations for a UV/soft x-ray beamline: Electron Spectro-Microscopy beamline at NSLS-II

    NASA Astrophysics Data System (ADS)

    Canestrari, N.; Bisogni, V.; Walter, A.; Zhu, Y.; Dvorak, J.; Vescovo, E.; Chubar, O.

    2014-09-01

    A "source-to-sample" wavefront propagation analysis of the Electron Spectro-Microscopy (ESM) UV / soft X-ray beamline, which is under construction at the National Synchrotron Light Source II (NSLS-II) in the Brookhaven National Laboratory, has been conducted. All elements of the beamline - insertion device, mirrors, variable-line-spacing gratings and slits - are included in the simulations. Radiation intensity distributions at the sample position are displayed for representative photon energies in the UV range (20 - 100 eV) where diffraction effects are strong. The finite acceptance of the refocusing mirrors is the dominating factor limiting the spatial resolution at the sample (by ~3 μm at 20 eV). Absolute estimates of the radiation flux and energy resolution at the sample are also obtained from the electromagnetic calculations. The analysis of the propagated UV range undulator radiation at different deflection parameter values demonstrates that within the beamline angular acceptance a slightly "red-shifted" radiation provides higher flux at the sample and better energy resolution compared to the on-axis resonant radiation of the fundamental harmonic.

  20. CE: Original Research: Does Certification in Vascular Access Matter? An Analysis of the PICC1 Survey.

    PubMed

    Chopra, Vineet; Kuhn, Latoya; Vaughn, Valerie; Ratz, David; Winter, Suzanne; Moureau, Nancy; Meyer, Britt; Krein, Sarah

    2017-12-01

    : Background: Although certification by an accredited agency is often a practice prerequisite in health care, it is not required of vascular access specialists who insert peripherally inserted central catheters (PICCs). Whether certification is associated with differences in practice among inserters is unknown. The purpose of this study was to gather information regarding whether certified and noncertified PICC inserters differ with respect to their practices and views about PICC use. We conducted a national survey of vascular access specialists, identifying certified PICC inserters as those who had received board certification from the Association for Vascular Access, the Infusion Nurses Society, or both. The 76-item survey asked about PICC policies and procedures at respondents' facilities, use of insertion technologies, device management, management of complications, perceptions about PICC use, and relationships with other health care providers. Additional data about respondents, including years in practice and primary practice settings, were also gathered. Bivariable comparisons were made using χ tests; two-sided α with P ≤ 0.05 was considered statistically significant. Of the 1,450 respondents in the final sample, 1,007 (69%) said they were certified inserters and 443 (31%) said they were not. Significantly higher percentages of certified than noncertified inserters reported having practiced for five or more years (78% versus 54%) and having placed 1,000 or more PICCs (58% versus 32%). Significantly more certified than noncertified inserters also reported being the vascular access lead for their facility (56% versus 44%). Reported practice patterns for insertion, care, and management of PICCs varied based on certification status. Some evidence-based practices (such as the use of ultrasound to measure catheter-to-vein ratios) were more often reported by certified inserters, while others (such as the use of maximal sterile barriers during PICC insertion) were not. Asked about their perceptions of PICC use at their institution, certified inserters reported higher percentages of inappropriate insertion and removal than noncertified inserters. Certified PICC inserters appear to be a distinct group of vascular access specialists. A better understanding of how and why practices differ between certified and noncertified inserters is necessary to ensuring safer, high-quality patient care.

Top