Sample records for spear3 light source

  1. Study of ultra-low emittance design for SPEAR3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, M. -H.; Huang, X.; Safranek, J.

    2015-09-17

    Since its 2003 construction, the SPEAR3 synchrotron light source at SLAC has continuously improved its performance by raising beam current, top-off injection, and smaller emittance. This makes SPEAR3 one of the most productive light sources in the world. Now, to further enhance the performance of SPEAR3, we are looking into the possibility of converting SPEAR3 to an ultra-low emittance storage ring within its site constraint.

  2. Study of ultra-low emittance design for Spear3 using longitudinal gradient dipole

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, M. -H.; Huang, X.; Safranek, J.

    2015-09-24

    Since its 2003 construction, the SPEAR3 synchrotron light source at SLAC has continuously improved its performance by raising beam current, top-off injection, and smaller emittance. This makes SPEAR3 one of the most productive light sources in the world. Now to further enhance the performance of SPEAR3, we are looking into the possibility of converting SPEAR3 to an ultra-low emittance storage ring within its site constraint.

  3. Source characteristics and design consideration for an iron-free variable-period/polarizing undulator for the UV/VUV range on SPEAR (abstract)

    NASA Astrophysics Data System (ADS)

    Tatchyn, Roman

    1992-01-01

    Insertion devices that are tuned by electrical period variation are particularly suited for the design of flexible polarized-light sources [R. Tatchyn, J. Appl. Phys. 65, 4107 (1989); R. Tatchyn and T. Cremer, IEEE Trans. Mag. 26, 3102 (1990)]. Important advantages vis-a-vis mechanical or hybrid variable field designs include: (1) significantly more rapid modulation of both polarization and energy, (2) an inherently larger set of polarization modulation capabilities and (3) polarization/energy modulation at continuously optimized values of K. In this paper we outline some of the general considerations that enter into the design of hysteresis-free variable-period/polarizing undulator structures and present the parameters of a recently-completed prototype design capable of generating intense levels of UV/VUV photon flux on SPEAR running at 3 GeV.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, H. D.; Fiorito, R. B.; Corbett, J.

    The 3GeV SPEAR3 synchrotron light source operates in top-up injection mode with up to 500 mA circulating in the storage ring (equivalently 392 nC). Each injection pulse contains 40–80 pC producing a contrast ratio between total stored charge and injected charge of about 6500:1. In order to study transient injected beam dynamics during user operations, it is desirable to optically image the injected pulse in the presence of the bright stored beam. In the present work this is done by imaging the visible component of the synchrotron radiation onto a digital micro-mirror-array device (DMD), which is then used as anmore » optical mask to block out light from the bright central core of the stored beam. The physical masking, together with an asynchronously-gated, ICCD imaging camera, makes it possible to observe the weak injected beam component on a turn-by-turn basis. The DMD optical masking system works similar to a classical solar coronagraph but has some distinct practical advantages: i.e. rapid adaption to changes in the shape of the stored beam, a high extinction ratio for unwanted light and minimum scattering from the primary beam into the secondary optics. In this paper we describe the DMD masking method, features of the high dynamic range point spread function for the SPEAR3 optical beam line and measurements of the injected beam in the presence of the stored beam.« less

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Hao; Fiorito, Ralph; Corbett, Jeff

    The 3GeV SPEAR3 synchrotron light source operates in top-up injection mode with up to 500mA circulating in the storage ring (equivalently 392nC). Each injection pulse contains only 40-80 pC producing a contrast ratio between total stored charge and injected charge of about 6500:1. In order to study transient injected beam dynamics during User operations, it is desirable to optically image the injected pulse in the presence of the bright stored beam. In the present work this is done by re-imaging visible synchrotron radiation onto a digital micro-mirror-array device (DMD), which is then used as an optical mask to block outmore » light from the bright central core of the stored beam. The physical masking, together with an asynchronously-gated, ICCD imaging camera makes it is possible to observe the weak injected beam component on a turn-by-turn basis. The DMD optical masking system works similar to a classical solar coronagraph but has some distinct practical advantages: i.e. rapid adaption to changes in the shape of the stored beam, high extinction ratio for unwanted light and minimum scattering from the primary beam into the secondary optics. In this paper we describe the DMD masking method, features of the high dynamic range point spread function for the SPEAR3 optical beam line and measurements of the injected beam in the presence of the stored beam.« less

  6. SPEAR — ToF neutron reflectometer at the Los Alamos Neutron Science Center

    NASA Astrophysics Data System (ADS)

    Dubey, M.; Jablin, M. S.; Wang, P.; Mocko, M.; Majewski, J.

    2011-11-01

    This article discusses the Surface ProfilE Analysis Reflectometer (SPEAR), a vertical scattering geometry time-of-flight reflectometer, at the Los Alamos National Laboratory Lujan Neutron Scattering Center. SPEAR occupies flight path 9 and receives spallation neutrons from a polychromatic, pulsed (20Hz) source that pass through a liquid-hydrogen moderator at 20K coupled with a Be filter to shift their energy spectrum. The spallation neutrons are generated by bombarding a tungsten target with 800MeV protons obtained from an accelerator. The process produces an integrated neutron flux of ˜ 3.4×106 cm-2 s-1 at a proton current of 100 μA. SPEAR employs choppers and frame overlap mirrors to obtain a neutron wavelength range of 4.5-16 Å. SPEAR uses a single 200mm long 3He linear position-sensitive detector with ˜ 2 mm FWHM resolution for simultaneous studies of both specular and off-specular scattering. SPEAR's moderated neutrons are collimated into a beam which impinges from above upon a level sample with an average angle of 0.9° to the horizontal, to facilitate air-liquid interface studies. In the vertical direction, the beam converges at the sample position. The neutrons can be further collimated to the desired divergence by finely slitting the beam using a set of two 10B4C slit packages. The instrument is ideally suited to study organic and inorganic thin films with total thicknesses between 5 and 3000 Å in a variety of environments. Specifically designed sample chambers available at the instrument provide the opportunity to study biological systems at the solid-liquid interface. SPEAR's unique experimental capabilities are demonstrated by specific examples in this article. Finally, an outlook for SPEAR and perspectives on future instrumentation are discussed.

  7. The Other End of the Spear: The Tooth-to-Tail Ratio (T3R) in Modern Military Operations

    DTIC Science & Technology

    2007-01-01

    units. Such a vehicle gave infantry much more of the fi repower and survivability inherent in heavy (mechanized infantry and armored) units while...The Other End of the Spear: The Tooth- to-Tail Ratio (T3R) in Modern Military Operations John J. McGrath The Long War Series Occasional Paper 23...collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources

  8. Stanford Synchrotron Radiation Laboratory activity report for 1986

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cantwell, K.

    1987-12-31

    1986 was another year of major advances for SSRL as the ultimate capabilities of PEP as a synchrotron radiation source became more apparent and a second PEP beam line was initiated, while effective development and utilization of SPEAR proceeded. Given these various PEP developments, SSRL abandoned its plans for a separate diffraction limited ring, as they abandoned their plans for a 6--7 GeV ring of the APS type last year. It has become increasingly apparent that SSRL should concentrate on developing SPEAR and PEP as synchrotron radiation sources. Consequently, initial planning for a 3 GeV booster synchrotron injector for SPEARmore » was performed in 1986, with a proposal to the Department of Energy resulting. As described in Chapter 2, the New Rings Group and the Machine Physics Group were combined into one Accelerator Physics Group. This group is focusing mainly on the improvement of SPEAR`s operating conditions and on planning for the conversion of PEP into a fourth generation x-ray source. Considerable emphasis is also being given to the training of accelerator physics graduate students. At the same time, several improvements of SSRL`s existing facilities were made. These are described in Chapter 3. Chapter 4 describes new SSRL beam lines being commissioned. Chapter 5 discusses SSRL`s present construction projects. Chapter 6 discusses a number of projects presently underway in the engineering division. Chapter 7 describes SSRL`s advisory panels while Chapter 8 discusses SSRL`s overall organization. Chapter 9 describes the experimental progress reports.« less

  9. 1990 Activity report for 1986-1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cantwell, K.

    1996-01-01

    As discussed in last year`s Activity Report, a fairly complete analysis of SPEAR problems was performed in concert with SLAC, and a major maintenance/improvement process was initiated in the spring of 1989. This run made it apparent that SPEAR will remain a very useful and impressive synchrotron radiation storage ring for at least a decade, given a steady maintenance and improvement program. More details about SPEAR functioning during the run, as well as SPEAR improvements, are contained in Chapter I. The formal SPEAR injector construction project was completed in November, 1990, on-time and on-budget. Although DOE was not able tomore » provide anticipated FY90 commissioning funds, preliminary commissioning was performed and 2.3 GeV injection to SPEAR was demonstrated. A discussion of the Injector project is contained in Chapter II. Commissioning of the injector and the injector/SPEAR complex is continuing in 1991 with Users participating during the May-September period. This user participation allowed normal experimentation, so that systems could be tested critically, but with the commissioning process having higher priority than data acquisition. Another major event in 1990 was the full dedication of SPEAR to the synchrotron radiation program. Previously SPEAR was considered a high energy physics machine that was partially dedicated to synchrotron radiation. The full dedication means that the accelerator can be modified and improved for synchrotron radiation research. Despite the heavy emphasis on completing the Injector, many beam line improvements were achieved, as described in Chapter IV. Among these was the optimization of stations 6-2 and 10-2, the provision of a considerably larger hutch for Station 1-5, which contains the area detector diffractometer, and the introduction of white light capability on 10-2. The provision of good beam during the month of April made an appreciable amount of experimentation possible. These and other runs are described in Chapter VI.« less

  10. Structured Metal Film as Perfect Absorber

    NASA Astrophysics Data System (ADS)

    Xiong, Xiang; Jiang, Shang-Chi; Peng, Ru-Wen; Wang, Mu

    2014-03-01

    With standing U-shaped resonators, fish-spear-like resonator has been designed for the first time as the building block to assemble perfect absorbers. The samples have been fabricated with two-photon polymerization process and FTIR measurement results support the effectiveness of the perfect absorber design. In such a structure the polarization-dependent resonance occurs between the tines of the spears instead of the conventional design where the resonance occurs between the metallic layers separated by a dielectric interlayer. The incident light neither transmits nor reflects back which results in unit absorbance. The power of light is trapped between the tines of spears and finally be absorbed. The whole structure is covered with a continuous metallic layer with good thermo-conductance, which provides an excellent approach to deal with heat dissipation, is enlightening in exploring metamaterial absorbers.

  11. 1994 SSRL Activity Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2011-11-18

    SSRL, a division of the Stanford Linear Accelerator Center, is a national user facility which provides synchrotron radiation, a name given to x-rays or light produced by electrons circulating in a storage ring at nearly the speed of light. The synchrotron radiation is produced by the 3.3 GeV storage ring, SPEAR. SPEAR is a fully dedicated synchrotron radiation facility which has been operating for user experiments 6 to 7 months per year. 1994, the third year of operation of SSRL as a fully dedicated, low-emittance, independent user facility was superb. The facility ran extremely well, delivering 89% of the scheduledmore » user beam to 25 experimental stations during 6.5 months of user running. Over 600 users came from 167 institutions to participate in 343 experiments. Users from private industry were involved in 31% of these experiments. The SPEAR accelerator ran very well with no major component failures and an unscheduled down time of only 2.9%. In addition to this increased reliability, there was a significant improvement in the stability of the beam. The enhancements to the SPEAR orbit as part of a concerted three-year program were particularly noticeable to users. the standard deviation of beam movement (both planes) in the last part of the run was 80 microns, major progress toward the ultimate goal of 50-micron stability. This was a significant improvement from the previous year when the movement was 400 microns in the horizontal and 200 microns in the vertical. A new accelerator Personal Protection System (PPS), built with full redundancy and providing protection from both radiation exposure and electrical hazards, was installed in 1994.« less

  12. Meteor Beliefs Project: Spears of GodSpears of God

    NASA Astrophysics Data System (ADS)

    Hendrix, Howard V.; McBeath, Alastair; Gheorghe, Andrei Dorian

    2012-04-01

    A selection of genuine or supposedly sky-fallen objects from real-world sources, a mixture of weapons, tools and "magical" objects of heavenly provenance, are drawn from their re-use in the near-future science-fiction novel Spears of God by author Howard V Hendrix, with additional discussion. The book includes other meteoric and meteoritic items too, some of which have been the subject of previous Meteor Beliefs Project examinations.

  13. Optimization of Dynamic Aperture of PEP-X Baseline Design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Min-Huey; /SLAC; Cai, Yunhai

    2010-08-23

    SLAC is developing a long-range plan to transfer the evolving scientific programs at SSRL from the SPEAR3 light source to a much higher performing photon source. Storage ring design is one of the possibilities that would be housed in the 2.2-km PEP-II tunnel. The design goal of PEPX storage ring is to approach an optimal light source design with horizontal emittance less than 100 pm and vertical emittance of 8 pm to reach the diffraction limit of 1-{angstrom} x-ray. The low emittance design requires a lattice with strong focusing leading to high natural chromaticity and therefore to strong sextupoles. Themore » latter caused reduction of dynamic aperture. The dynamic aperture requirement for horizontal injection at injection point is about 10 mm. In order to achieve the desired dynamic aperture the transverse non-linearity of PEP-X is studied. The program LEGO is used to simulate the particle motion. The technique of frequency map is used to analyze the nonlinear behavior. The effect of the non-linearity is tried to minimize at the given constrains of limited space. The details and results of dynamic aperture optimization are discussed in this paper.« less

  14. Booster Synchrotron RF System Upgrade for SPEAR3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Sanghyun; /SLAC; Corbett, Jeff

    2012-07-06

    Recent progress at the SPEAR3 includes the increase in stored current from 100 mA to 200 mA and top-off injection to allow beamlines to stay open during injection. Presently the booster injects 3.0 GeV beam to SPEAR3 three times a day. The stored beam decays to about 150 mA between the injections. The growing user demands are to increase the stored current to the design value of 500 mA, and to maintain it at a constant value within a percent or so. To achieve this goal the booster must inject once every few minutes. For improved injection efficiency, all RFmore » systems at the linac, booster and SPEAR3 need to be phase-locked. The present booster RF system is basically a copy of the SPEAR2 RF system with 358.5 MHz and 40 kW peak RF power driving a 5-cell RF cavity for 1.0 MV gap voltage. These requirements entail a booster RF system upgrade to a scaled down version of the SPEAR3 RF system of 476.3 MHz with 1.2 MW cw klystron output power capabilities. We will analyze each subsystem option for their merits within budgetary and geometric space constraints. A substantial portion of the system will come from the decommissioned PEP-II RF stations.« less

  15. Stanford Synchrotron Radiation Laboratory. Activity report for 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-01-01

    The April, 1990 SPEAR synchrotron radiation run was one of the two or three best in SSRL`s history. High currents were accumulated, ramping went easily, lifetimes were long, beam dumps were infrequent and the average current was 42.9 milliamps. In the one month of operation, 63 different experiments involving 208 scientists from 50 institutions received beam. The end-of-run summary forms completed by the experimenters indicated high levels of user satisfaction with the beam quality and with the outstanding support received from the SSRL technical and scientific staffs. These fine experimental conditions result largely from the SPEAR repairs and improvements performedmore » during the past year and described in Section I. Also quite significant was Max Cornacchia`s leadership of the SLAG staff. SPEAR`s performance this past April stands in marked contrast to that of the January-March, 1989 run which is also described in Section I. It is, we hope, a harbinger of the operation which will be provided in FY `91, when the SPEAR injector project is completed and SPEAR is fully dedicated to synchrotron radiation research. Over the coming years, SSRL intends to give highest priority to increasing the effectiveness of SPEAR and its various beam lines. The beam line and facility improvements performed during 1989 are described in Section III. In order to concentrate effort on SSRL`s three highest priorities prior to the March-April run: (1) to have a successful run, (2) to complete and commission the injector, and (3) to prepare to operate, maintain and improve the SPEAR/injector system, SSRL was reorganized. In the new organization, all the technical staff is contained in three groups: Accelerator Research and Operations Division, Injector Project and Photon Research and Operations Division, as described in Section IV. In spite of the limited effectiveness of the January-March, 1989 run, SSRL`s users made significant scientific progress, as described in Section V of this report.« less

  16. The Incidence of Spearing during a High School's 1975 and 1990 Football Seasons.

    ERIC Educational Resources Information Center

    Heck, Jonathan F.

    1996-01-01

    Reports a study that examined the incidence of spearing between two high school football seasons, one before and one after a rule change banning spearing. Reviews of 18 game films of a New Jersey team from 1975 and 1990 indicated that, overall, the rule change did not have a favorable impact on the incidence of spearing. (SM)

  17. Fishing for Northern Pike in Minnesota: A comparison of anglers and dark house spearers

    USGS Publications Warehouse

    Schroeder, Susan A.; Fulton, David C.

    2014-01-01

    In order to project fishing effort and demand of individuals targeting Northern Pike Esox lucius in Minnesota, it is important to understand the catch orientations, management preferences, and site choice preferences of those individuals. Northern Pike are specifically targeted by about 35% of the approximately 1.5 million licensed anglers in Minnesota and by approximately 14,000–15,000 dark house spearers. Dark house spearing is a traditional method of harvesting fish through the ice in winter. Mail surveys were distributed to three research strata: anglers targeting Northern Pike, dark house spearing license holders spearing Northern Pike, and dark house spearing license holders angling for Northern Pike. Dark house spearers, whether spearing or angling, reported a stronger orientation toward keeping Northern Pike than did anglers. Anglers reported a stronger orientation toward catching large Northern Pike than did dark house spearers when spearing or angling. Northern Pike regulations were the most important attribute affecting site choice for respondents in all three strata. Models for all strata indicated a preference for lakes without protected slot limits. However, protected slot limits had a stronger negative influence on lake preference for dark house spearing licensees (whether spearing or angling) than for anglers.

  18. Omen: identifying potential spear-phishing targets before the email is sent.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wendt, Jeremy Daniel.

    2013-07-01

    We present the results of a two year project focused on a common social engineering attack method called "spear phishing". In a spear phishing attack, the user receives an email with information specifically focused on the user. This email contains either a malware-laced attachment or a link to download the malware that has been disguised as a useful program. Spear phishing attacks have been one of the most effective avenues for attackers to gain initial entry into a target network. This project focused on a proactive approach to spear phishing. To create an effective, user-specific spear phishing email, the attackermore » must research the intended recipient. We believe that much of the information used by the attacker is provided by the target organization's own external website. Thus when researching potential targets, the attacker leaves signs of his research in the webserver's logs. We created tools and visualizations to improve cybersecurity analysts' abilities to quickly understand a visitor's visit patterns and interests. Given these suspicious visitors and log-parsing tools, analysts can more quickly identify truly suspicious visitors, search for potential spear-phishing targeted users, and improve security around those users before the spear phishing email is sent.« less

  19. Cluster spacecraft observations of a ULF wave enhanced by Space Plasma Exploration by Active Radar (SPEAR)

    NASA Astrophysics Data System (ADS)

    Badman, S. V.; Wright, D. M.; Clausen, L. B. N.; Fear, R. C.; Robinson, T. R.; Yeoman, T. K.

    2009-09-01

    Space Plasma Exploration by Active Radar (SPEAR) is a high-latitude ionospheric heating facility capable of exciting ULF waves on local magnetic field lines. We examine an interval from 1 February 2006 when SPEAR was transmitting a 1 Hz modulation signal with a 10 min on-off cycle. Ground magnetometer data indicated that SPEAR modulated currents in the local ionosphere at 1 Hz, and enhanced a natural field line resonance with a 10 min period. During this interval the Cluster spacecraft passed over the heater site. Signatures of the SPEAR-enhanced field line resonance were present in the magnetic field data measured by the magnetometer on-board Cluster-2. These are the first joint ground- and space-based detections of field line tagging by SPEAR.

  20. An Experimental Investigation of the Functional Hypothesis and Evolutionary Advantage of Stone-Tipped Spears

    PubMed Central

    Wilkins, Jayne; Schoville, Benjamin J.; Brown, Kyle S.

    2014-01-01

    Stone-tipped weapons were a significant innovation for Middle Pleistocene hominins. Hafted hunting technology represents the development of new cognitive and social learning mechanisms within the genus Homo, and may have provided a foraging advantage over simpler forms of hunting technology, such as a sharpened wooden spear. However, the nature of this foraging advantage has not been confirmed. Experimental studies and ethnographic reports provide conflicting results regarding the relative importance of the functional, economic, and social roles of hafted hunting technology. The controlled experiment reported here was designed to test the functional hypothesis for stone-tipped weapons using spears and ballistics gelatin. It differs from previous investigations of this type because it includes a quantitative analysis of wound track profiles and focuses specifically on hand-delivered spear technology. Our results do not support the hypothesis that tipped spears penetrate deeper than untipped spears. However, tipped spears create a significantly larger inner wound cavity that widens distally. This inner wound cavity is analogous to the permanent wound cavity in ballistics research, which is considered the key variable affecting the relative ‘stopping power’ or ‘killing power’ of a penetrating weapon. Tipped spears conferred a functional advantage to Middle Pleistocene hominins, potentially affecting the frequency and regularity of hunting success with important implications for human adaptation and life history. PMID:25162397

  1. Solid State Research, 1975:3

    DTIC Science & Technology

    1975-08-15

    Heckscher T. F. Deutsch H. Kildal D. L. Spears I. Melngailis T. C. Haiman P. L. Kelley R. S. Eng D. L. Spears H. R. Fetterman H. R... Fetterman H. R. Schlossberg* W. E. Barch 1975 International IEEE/APS Symposium and USNC/URSI Meeting, Urbana, Illinois, 4 June 1975 * Author not...ft. Chinn, S. R. Del-eo, ft. E. Deutsch, T. F. Fetterman , II. R. Hancock, R. C. II. Ileckscher, Kildal, II. Larsen, D. M. Mandel, P

  2. A Systems Engineering Process for an Integrated Structural Health Monitoring System

    DTIC Science & Technology

    2007-03-01

    York NY, 1999. 2nd ed. 3. Chambers, Jeffrey T., Brian L. Wardle, and Seth S. Kessler . “Durability Assessment of Lamb Wave-Based Structural Health...Institute of Technology, 1960. 222 Bibliography 10. Kessler , Seth S., S. Mark Spearing, Mauro J. Atalla, Carlos E. S. Cesnik, and Constantinos...Materials, March 4-8 2001, Newport Beach, CA. Available at http://web.mit.edu/sskess/www/papers/SPIE01.pdf. 11. Kessler , Seth S., S. Mark Spearing

  3. 75 FR 53953 - The National Saltwater Angler Registry Program; Designation of Exempted States for Anglers, Spear...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-02

    ... DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration RIN 0648-XX66 The National Saltwater Angler Registry Program; Designation of Exempted States for Anglers, Spear Fishers, and For-Hire... as exempted states for anglers, spear fishers and for-hire fishing vessels. NMFS has designated the...

  4. What Can We Learn About the Ionosphere Using the EISCAT Heating Facility?

    DTIC Science & Technology

    2006-06-01

    1970s to do both plasma physics and geophysical research. At present there are five operating facilities: HIPAS [1] and HAARP [2] in Alaska, Heating...1995: HAARP (Alaska) •2003: SPEAR (Svalbard) World overview 32 (8) 22 (16) 0.19 4-6 (2-3) 78.9 N 78.15 W SPEAR Spitsbergen Norway 150-280180-340...19.2 E 62.39 N 145.15W 65.0 N 147.0 W 18.3 N 66.8 W 40.18 N 104.73 E Geographic Coordinates SURA Russia Tromsø Norway HAARP Alaska USA HIPAS Alaska

  5. Nonlinear dynamics optimization with particle swarm and genetic algorithms for SPEAR3 emittance upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Xiaobiao; Safranek, James

    2014-09-01

    Nonlinear dynamics optimization is carried out for a low emittance upgrade lattice of SPEAR3 in order to improve its dynamic aperture and Touschek lifetime. Two multi-objective optimization algorithms, a genetic algorithm and a particle swarm algorithm, are used for this study. The performance of the two algorithms are compared. The result shows that the particle swarm algorithm converges significantly faster to similar or better solutions than the genetic algorithm and it does not require seeding of good solutions in the initial population. These advantages of the particle swarm algorithm may make it more suitable for many accelerator optimization applications.

  6. Impacts of pesticide mixtures in European rivers as predicted by the Species Sensitivity Distribution (SSD) models and SPEAR bioindication

    NASA Astrophysics Data System (ADS)

    Jesenska, Sona; Liess, Mathias; Schäfer, Ralf; Beketov, Mikhail; Blaha, Ludek

    2013-04-01

    Species sensitivity distribution (SSD) is statistical method broadly used in the ecotoxicological risk assessment of chemicals. Originally it has been used for prospective risk assessment of single substances but nowadays it is becoming more important also in the retrospective risk assessment of mixtures, including the catchment scale. In the present work, SSD predictions (impacts of mixtures consisting of 25 pesticides; data from several catchments in Germany, France and Finland) were compared with SPEAR-pesticides, which a bioindicator index based on biological traits responsive to the effects of pesticides and post-contamination recovery. The results showed statistically significant correlations (Pearson's R, p<0.01) between SSD (predicted msPAF values) and values of SPEAR-pesticides (based on field biomonitoring observations). Comparisons of the thresholds established for the SSD and SPEAR approaches (SPEAR-pesticides=45%, i.e. LOEC level, and msPAF = 0.05 for SSD, i.e. HC5) showed that use of chronic toxicity data significantly improved the agreement between the two methods but the SPEAR-pesticides index was still more sensitive. Taken together, the validation study shows good potential of SSD models in predicting the real impacts of micropollutant mixtures on natural communities of aquatic biota.

  7. Excitation thresholds of field-aligned irregularities and associated ionospheric hysteresis at very high latitudes observed using SPEAR-induced HF radar backscatter

    NASA Astrophysics Data System (ADS)

    Wright, D. M.; Dhillon, R. S.; Yeoman, T. K.; Robinson, T. R.; Thomas, E. C.; Baddeley, L. J.; Imber, S.

    2009-07-01

    On 10 October 2006 the SPEAR high power radar facility was operated in a power-stepping mode where both CUTLASS radars were detecting backscatter from the SPEAR-induced field-aligned irregularities (FAIs). The effective radiated power of SPEAR was varied from 1-10 MW. The aim of the experiment was to investigate the power thresholds for excitation (Pt) and collapse (Pc) of artificially-induced FAIs in the ionosphere over Svalbard. It was demonstrated that FAI could be excited by a SPEAR ERP of only 1 MW, representing only 1/30th of SPEAR's total capability, and that once created the irregularities could be maintained for even lower powers. The experiment also demonstrated that the very high latitude ionosphere exhibits hysteresis, where the down-going part of the power cycle provided a higher density of irregularities than for the equivalent part of the up-going cycle. Although this second result is similar to that observed previously by CUTLASS in conjunction with the Tromsø heater, the same is not true for the equivalent incoherent scatter measurements. The EISCAT Svalbard Radar (ESR) failed to detect any hysteresis in the plasma parameters over Svalbard in stark contract with the measurements made using the Tromsø UHF.

  8. STAR Performance with SPEAR (Signal Processing Electronic Attack RFIC)

    DTIC Science & Technology

    2017-03-01

    STAR operation in the presence of 1 kW EIRP power , independently of the choice of transmitter in use. The paper reports on the status of the SPEAR...prototype will be presented. To the authors’ knowledge , the measured results from the prototype already demonstrate state-of-the-art STAR performance...self-generated high power interferers. SPEAR is an innovative approach to the full duplex challenge that meets the high demands of military systems

  9. Evolution of quality characteristics of minimally processed asparagus during storage in different lighting conditions.

    PubMed

    Sanz, S; Olarte, C; Ayala, F; Echávarri, J F

    2009-08-01

    The effect of different types of lighting (white, green, red, and blue light) on minimally processed asparagus during storage at 4 degrees C was studied. The gas concentrations in the packages, pH, mesophilic counts, and weight loss were also determined. Lighting caused an increase in physiological activity. Asparagus stored under lighting achieved atmospheres with higher CO(2) and lower O(2) content than samples kept in the dark. This activity increase explains the greater deterioration experienced by samples stored under lighting, which clearly affected texture and especially color, accelerating the appearance of greenish hues in the tips and reddish-brown hues in the spears. Exposure to light had a negative effect on the quality parameters of the asparagus and it caused a significant reduction in shelf life. Hence, the 11 d shelf life of samples kept in the dark was reduced to only 3 d in samples kept under red and green light, and to 7 d in those kept under white and blue light. However, quality indicators such as the color of the tips and texture showed significantly better behavior under blue light than with white light, which allows us to state that it is better to use this type of light or blue-tinted packaging film for the display of minimally processed asparagus to consumers.

  10. Spacecraft-plasma interaction codes: NASCAP/GEO, NASCAP/LEO, POLAR, DynaPAC, and EPSAT

    NASA Technical Reports Server (NTRS)

    Mandell, M. J.; Jongeward, G. A.; Cooke, D. L.

    1992-01-01

    Development of a computer code to simulate interactions between the surfaces of a geometrically complex spacecraft and the space plasma environment involves: (1) defining the relevant physical phenomena and formulating them in appropriate levels of approximation; (2) defining a representation for the 3-D space external to the spacecraft and a means for defining the spacecraft surface geometry and embedding it in the surrounding space; (3) packaging the code so that it is easy and practical to use, interpret, and present the results; and (4) validating the code by continual comparison with theoretical models, ground test data, and spaceflight experiments. The physical content, geometrical capabilities, and application of five S-CUBED developed spacecraft plasma interaction codes are discussed. The NASA Charging Analyzer Program/geosynchronous earth orbit (NASCAP/GEO) is used to illustrate the role of electrostatic barrier formation in daylight spacecraft charging. NASCAP/low Earth orbit (LEO) applications to the CHARGE-2 and Space Power Experiment Aboard Rockets (SPEAR)-1 rocket payloads are shown. DynaPAC application to the SPEAR-2 rocket payloads is described. Environment Power System Analysis Tool (EPSAT) is illustrated by application to Tethered Satellite System 1 (TSS-1), SPEAR-3, and Sundance. A detailed description and application of the Potentials of Large Objects in the Auroral Region (POLAR) Code are presented.

  11. An Archeological Survey of the Cross Ditch No.2 and Central Ditch Cleanout Project Poinsett County, Arkansas

    DTIC Science & Technology

    1986-10-01

    REPORT October 1986 Report prepared by 0 % -’• Rt. 1 Box 186 ,o, West Fork, AR 72774 000 w ua0’ (501) 839-3663 0fr Memphis District, Corps of Engineers...Cleanout Project Poisett Co., AR c DACW66-86-M-1097 6. AUTHORS) Robert A. Taylor Carol S. Spears 7. PERFORW6NG ORGAN.ZATiON ANtMES) AND AD.JE.S3ýES) 8...ý-KiGkMING ORGANiAT.,NR•EPORT NUMEER Spears Professional Environmental & Archaeological Researcl Service West Fork, AR 9. SPONSORING MCNTO7’.G AG

  12. 15 CFR 922.71 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...). Stowed and not available for immediate use means not readily accessible for immediate use, e.g., by being... (such as spear shafts being kept separate from spear guns). [74 FR 3260, Jan. 16, 2009] ...

  13. 75 FR 9531 - Magnuson-Stevens Act Provisions; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-03

    ..., rod and reel, spear, trap, slurp gun, hand harvest. C. Charter fishery C. Bandit gear, buoy gear..., gillnet, hand harvest, seine, slurp gun, trap, spear, rod and reel, hook and line. 12. Recreational...

  14. 75 FR 72793 - National Saltwater Angler Registry Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-26

    ... fifteen dollars ($15.00) for registration of anglers, spear fishers and for-hire fishing vessels to... anglers, spear fishers and for-hire fishing vessels will be fifteen dollars ($15.00). All persons...

  15. Space Plasma Exploration by Active Radar (SPEAR induced modifications of the high latitude (78°N) ionosphere observed by both coherent and incoherent radars (Invited)

    NASA Astrophysics Data System (ADS)

    Baddeley, L. J.; Haggstrom, I.; Wright, D. M.; Isham, B.; Gallop, P.

    2010-12-01

    The SPEAR (Space Plasma Exploration by Active Radar) system, which is the newest operational heating facility, is located on Svalbard at 78°N (75° CGM) latitude and, as such, is the highest latitudinally located heating system. The unique geomagnetic location of SPEAR also allows it to be inside the Polar Cap at all local times. It is co-located with several facilities, including the EISCAT Incoherent Scatter Radar. The system is also inside the fields of view of several SuperDARN Coherent Scatter Radars. An overview of the SPEAR system, specific operating modes, as well as data from new, currently undergoing and planned experiments conducted in 2010 will be presented and discussed. Procedures for any future collaborative experiments will also be presented.

  16. Antiradical capacity and polyphenol composition of asparagus spears varieties cultivated under different sunlight conditions.

    PubMed

    Kulczyński, Bartosz; Kobus-Cisowska, Joanna; Kmiecik, Dominik; Gramza-Michałowska, Anna; Golczak, Dorota; Korczak, Józef

    2016-01-01

    Asparagus officinalis has a high nutritional value. Asparagus is rich in a number of bioactive compounds, mainly flavonoids (quercetin), glutathione, vitamin C, vitamin E, fructans (inulin and fructooligosaccharides) and phytosterols (b-sitosterol). These compounds may play an important role in human health. The purpose of this study was to examine the antioxidant potential and polyphenol composition of white, pale-colored and green asparagus spears of different cultivars. Investigations were conducted on different asparagus spear extracts. The study included three colors of asparagus (white, pale-colored and green) from five different cultivars subjected to the ethanol extraction procedure. Total phenolic content was also determined by the Folin-Ciocalteu method. Polyphenol (phenolic acids and flavonols) composition was estimated using the HPLC method. The antioxidant properties of extracts were examined using DPPH, ABTS and metal ion chelating assays. The highest contents of phenolic and flavonoids were observed in green asparagus from Grolim and the lowest in pale-colored asparagus from Gyjmlin. It was found that both the color of asparagus and the cultivar had a significant effect on the composition of phenolic acid and flavonols. Radical scavenging activity toward DPPH• and ABTS was highest for green asparagus cv. Grolim and Eposs. The greatest number of Fe ions was chelated by samples of green asparagus cv. Grolim and Huchel's Alpha and pale-colored asparagus cv. Huchel's Alpha. It was shown that the antioxidant activity of asparagus spears measured by antiradical and chelating activity test depends on variety and color. The highest activity was found in green asparagus and the lowest was identified in white asparagus extracts. It has also been clarified that changes in flavonol and phenolic acid composition and increases in their diversity depends on growing with sunlight and variety. Asparagus can provide a valuable source of phenolic compounds in the human diet.

  17. Soldier experiments and assessments using SPEAR speech control system for UGVs

    NASA Astrophysics Data System (ADS)

    Brown, Jonathan; Blanco, Chris; Czerniak, Jeffrey; Hoffman, Brian; Hoffman, Orin; Juneja, Amit; Ngia, Lester; Pruthi, Tarun; Liu, Dongqing

    2010-04-01

    This paper reports on a Soldier Experiment performed by the Army Research Lab's Human Research Engineering Directorate (HRED) Field Element located at the Maneuver Center of Excellence, Ft. Benning, and a Limited Use Assessment conducted by the Marine Corps Forces Pacific Command Experimentation Center (MEC) at Camp Pendleton evaluating the effectiveness of using speech commands to control an Unmanned Ground Vehicle. SPEAR, developed by Think-A-Move, Ltd., provides speech control of UGVs. SPEAR detects user speech in the ear canal with an earpiece containing an in-ear microphone. The system design provides up to 30 dB of passive noise reduction, enabling it to work well in high-noise environments, where traditional speech systems, using external microphones, fail; it also utilizes a proprietary speech recognition engine. SPEAR has been integrated with iRobot's PackBot 510 with FasTac Kit, and with Multi-Robot Operator Control Unit (MOCU), developed by SPAWAR Systems Center Pacific. These integrated systems allow speech to supplement the hand-controller for multi-modal control of different UGV functions simultaneously. HRED's experiment measured the impact of SPEAR on reducing the cognitive load placed on UGV Operators and the time to complete specific tasks. Army NCOs and Officer School Candidates participated in this experiment, which found that speech control was faster than manual control to complete tasks requiring menu navigation, as well as reducing the cognitive load on UGV Operators. The MEC assessment examined speech commands used for two different missions: Route Clearance and Cordon and Search; participants included Explosive Ordnance Disposal Technicians and Combat Engineers. The majority of the Marines thought it was easier to complete the mission scenarios with SPEAR than with only using manual controls, and that using SPEAR improved their situational awareness. Overall results of these Assessments are reported in the paper, along with possible applications to autonomous mine detection systems.

  18. Cell response to quasi-monochromatic light with different coherence

    NASA Astrophysics Data System (ADS)

    Budagovsky, A. V.; Solovykh, N. V.; Budagovskaya, O. N.; Budagovsky, I. A.

    2015-04-01

    The problem of the light coherence effect on the magnitude of the photoinduced cell response is discussed. The origins of ambiguous interpretation of the known experimental results are considered. Using the biological models, essentially differing in anatomy, morphology and biological functions (acrospires of radish, blackberry microsprouts cultivated in vitro, plum pollen), the effect of statistical properties of quasi-monochromatic light (λmax = 633 nm) on the magnitude of the photoinduced cell response is shown. It is found that for relatively low spatial coherence, the cell functional activity changes insignificantly. The maximal enhancement of growing processes (stimulating effect) is observed when the coherence length Lcoh and the correlation radius rcor are greater than the cell size, i.e., the entire cell fits into the field coherence volume. In this case, the representative indicators (germination of seeds and pollen, the spears length) exceeds those of non-irradiated objects by 1.7 - 3.9 times. For more correct assessment of the effect of light statistical properties on photocontrol processes, it is proposed to replace the qualitative description (coherent - incoherent) with the quantitative one, using the determination of spatial and temporal correlation functions and comparing them with the characteristic dimensions of the biological structures, e.g., the cell size.

  19. Beyond Historical Fiction: Speare's "The Witch of Blackbird Pond."

    ERIC Educational Resources Information Center

    Thuente, Mary Helen

    1985-01-01

    Reviews "The Witch of Blackbird Pond" by E. Speare to show how the full narrative power of the novel derives from the author's successful integration of two separate narrative genres: historical fiction and the folktale. (EL)

  20. First observations of stimulated electromagnetic emission in the ionosphere modified by the spear heating facility on Spitsbergen

    NASA Astrophysics Data System (ADS)

    Tereshchenko, E. D.; Yurik, R. Yu.; Yeoman, T. K.; Robinson, T. R.

    2008-11-01

    We present the first results of observations of the stimulated electromagnetic emission (SEE) in the ionosphere modified by the Space Plasma Exploration by Active Radar (SPEAR) heating facility. Observation of the SEE is the key method of ground-based diagnostics of the ionospheric plasma disturbances due to high-power HF radiation. The presented results were obtained during the heating campaign performed at the SPEAR facility in February-March 2007. Prominent SEE special features were observed in periods in which the critical frequency of the F 2 layer was higher than the pump-wave frequency (4.45 MHz). As an example, such special features as the downshifted maximum and the broad continuum in the region of negative detunings from the pump-wave frequency are presented. Observations clearly demonstrate that the ionosphere was efficiently excited by the SPEAR heating facility despite the comparatively low pump-wave power.

  1. Pesticides from wastewater treatment plant effluents affect invertebrate communities.

    PubMed

    Münze, Ronald; Hannemann, Christin; Orlinskiy, Polina; Gunold, Roman; Paschke, Albrecht; Foit, Kaarina; Becker, Jeremias; Kaske, Oliver; Paulsson, Elin; Peterson, Märit; Jernstedt, Henrik; Kreuger, Jenny; Schüürmann, Gerrit; Liess, Matthias

    2017-12-01

    We quantified pesticide contamination and its ecological impact up- and downstream of seven wastewater treatment plants (WWTPs) in rural and suburban areas of central Germany. During two sampling campaigns, time-weighted average pesticide concentrations (c TWA ) were obtained using Chemcatcher® passive samplers; pesticide peak concentrations were quantified with event-driven samplers. At downstream sites, receiving waters were additionally grab sampled for five selected pharmaceuticals. Ecological effects on macroinvertebrate structure and ecosystem function were assessed using the biological indicator system SPEAR pesticides (SPEcies At Risk) and leaf litter breakdown rates, respectively. WWTP effluents substantially increased insecticide and fungicide concentrations in receiving waters; in many cases, treated wastewater was the exclusive source for the neonicotinoid insecticides acetamiprid and imidacloprid in the investigated streams. During the ten weeks of the investigation, five out of the seven WWTPs increased in-stream pesticide toxicity by a factor of three. As a consequence, at downstream sites, SPEAR values and leaf litter degradation rates were reduced by 40% and 53%, respectively. The reduced leaf litter breakdown was related to changes in the macroinvertebrate communities described by SPEAR pesticides and not to altered microbial activity. Neonicotinoids showed the highest ecological relevance for the composition of invertebrate communities, occasionally exceeding the Regulatory Acceptable Concentrations (RACs). In general, considerable ecological effects of insecticides were observed above and below regulatory thresholds. Fungicides, herbicides and pharmaceuticals contributed only marginally to acute toxicity. We conclude that pesticide retention of WWTPs needs to be improved. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. An Introduction to SPEAR (Seismogram Picking Error from Analyst Review)

    NASA Astrophysics Data System (ADS)

    Zeiler, C. P.; Velasco, A. A.; Anderson, D.; Pingitore, N. E.

    2008-12-01

    A grassroots initiative began in February of 2008 at the University of Texas at El Paso to understand how seismologists measure earthquakes. The Seismogram Picking Error from Analyst Review (SPEAR) project is designed to be a forum where seismologists can propose, discuss and experimentally test theories on proper procedures to identify and measure seismic phases. We outline the history of seismogram analysis and explore areas of seismogram analysis that still need to be defined. The main concern for SPEAR, at this time, is the impact of picking errors produced by merging earthquake catalogs. Our initial effort has been to establish a common data set for seismologists to pick. The preliminary studies from this data set have shown that significant bias between authors of catalogs may exist. We provide techniques to ensure that these biases can be identified and correctly managed to provide accurate mergers of earthquake measurements. The overall goal of SPEAR is to provide a repository of information to aid seismologists in comparing and sharing measurements. We want to document in the repository and explore all aspects of the picking process, from the basics of learning how to read a seismogram to complex transformations and enhancements of signals. Your participation in SPEAR will aid the seismological community to close the knowledge gaps that exist in seismogram analysis.

  3. ‘Fire hardening’ spear wood does slightly harden it, but makes it much weaker and more brittle

    PubMed Central

    Chan, Tak Lok

    2016-01-01

    It is usually assumed that ‘fire hardening’ the tips of spears, as practised by hunter–gatherers and early Homo spp., makes them harder and better suited for hunting. This suggestion was tested by subjecting coppiced poles of hazel to a fire-hardening process and comparing their mechanical properties to those of naturally seasoned poles. A Shore D hardness test showed that fire treatment slightly increased the hardness of the wood, but flexural and impact tests showed that it reduced the strength and work of fracture by 30% and 36%, respectively. These results suggest that though potentially slightly sharper and more durable, fire-hardened tips would actually be more likely to break off when used, as may have been the case with the earliest known wooden tool, the Clacton spear. Fire might first have been used to help sharpen the tips of spears, and fire-hardening would have been a mostly negative side effect, not its primary purpose. PMID:27194289

  4. Scalable electrophysiology in intact small animals with nanoscale suspended electrode arrays

    NASA Astrophysics Data System (ADS)

    Gonzales, Daniel L.; Badhiwala, Krishna N.; Vercosa, Daniel G.; Avants, Benjamin W.; Liu, Zheng; Zhong, Weiwei; Robinson, Jacob T.

    2017-07-01

    Electrical measurements from large populations of animals would help reveal fundamental properties of the nervous system and neurological diseases. Small invertebrates are ideal for these large-scale studies; however, patch-clamp electrophysiology in microscopic animals typically requires invasive dissections and is low-throughput. To overcome these limitations, we present nano-SPEARs: suspended electrodes integrated into a scalable microfluidic device. Using this technology, we have made the first extracellular recordings of body-wall muscle electrophysiology inside an intact roundworm, Caenorhabditis elegans. We can also use nano-SPEARs to record from multiple animals in parallel and even from other species, such as Hydra littoralis. Furthermore, we use nano-SPEARs to establish the first electrophysiological phenotypes for C. elegans models for amyotrophic lateral sclerosis and Parkinson's disease, and show a partial rescue of the Parkinson's phenotype through drug treatment. These results demonstrate that nano-SPEARs provide the core technology for microchips that enable scalable, in vivo studies of neurobiology and neurological diseases.

  5. Spacecraft Observations of a ULF Wave Injected Onto Field Lines by SPEAR

    NASA Astrophysics Data System (ADS)

    Badman, S. V.; Wright, D. M.; Yeoman, T. K.; Clausen, L. B.; Fear, R. C.; Fazakerley, A. N.; Lucek, E. A.

    2008-12-01

    SPEAR (Space Exploration by Active Radar) is an ionospheric heating facility situated on Svalbard which is capable of exciting ULF waves on local magnetic field lines. Field-guided ULF waves can interact with the ionospheric Alfvén resonator (IAR) and produce parallel electric fields, which then accelerate electrons along the field line. Detection and study of these waves thus provides information on the properties of the IAR and auroral acceleration processes. We examine an interval from 1 February 2006 when SPEAR was transmitting with a 5 min on-off cycle. During this interval the Cluster spacecraft passed over the heater site. We discuss signatures of the SPEAR-generated wave identified in the Cluster field and electron measurements. One feature of interest is the periodic enhancement of electron fluxes in two broad energy bands (~10-100 eV and ~100-1000 eV) which occur out of phase with each other in the two different energy bands.

  6. 76 FR 4092 - National Saltwater Angler Registry Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-24

    ..., Florida and Louisiana as exempted States for anglers, spear fishers and for-hire fishing vessels. NMFS has... fishers. DATES: The designation of the States as exempted States is effective on January 24, 2011. [[Page... exempted States only for anglers and spear fishers: Massachusetts, Maryland, and Virginia. Massachusetts...

  7. Spear-Marked Black Moth

    Treesearch

    Richard A. Werner; Bruce H. Baker

    1977-01-01

    The spear-marked black moth, Rheumaptera hastata (L.) (Lepidoptera: Geometridae) is a serious defoliator of paper birch (Betula papyrifera Marsh.) in interior Alaska. Epidemic populations have occurred at 15- to 17- year intervals, persisted for 2 years, and then collapsed. Recorded outbreaks occurred in 1941, acreage unknown; from 1957 to 1958, 5 million acres (2...

  8. 50 CFR 600.725 - General prohibitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... and reel, spear. 19. Summer Flounder, Scup, Black Sea Bass Fishery (FMP managed by MAFMC): A. Trawl...-Atlantic Fishery Management Council (MAFMC) 1. Summer Flounder, Scup, Black Sea Bass Fishery (FMP): A... reel, bandit gear, handline, spear, powerhead. B. Black sea bass trap and pot fishery B. Pot, trap. C...

  9. 50 CFR 600.725 - General prohibitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... and reel, spear. 19. Summer Flounder, Scup, Black Sea Bass Fishery (FMP managed by MAFMC): A. Trawl...-Atlantic Fishery Management Council (MAFMC) 1. Summer Flounder, Scup, Black Sea Bass Fishery (FMP): A... reel, bandit gear, handline, spear, powerhead. B. Black sea bass trap and pot fishery B. Pot, trap. C...

  10. 50 CFR 600.725 - General prohibitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... and reel, spear. 19. Summer Flounder, Scup, Black Sea Bass Fishery (FMP managed by MAFMC): A. Trawl...-Atlantic Fishery Management Council (MAFMC) 1. Summer Flounder, Scup, Black Sea Bass Fishery (FMP): A... reel, bandit gear, handline, spear, powerhead. B. Black sea bass trap and pot fishery B. Pot, trap. C...

  11. SPEAR (Space Plasma Exploration by Active Radar): New Developments and Future Plans

    NASA Astrophysics Data System (ADS)

    Baddeley, L. J.; Oksavik, K.

    2009-12-01

    The SPEAR heating facility is located on Svalbard at 75° CGM latitude and as such is 10° closer to a geomagnetic pole than any current ionospheric heating facility. It thus has the unique ability to perform heating experiments inside the polar cap at all local times. It is co-located with several facilities, including the EISCAT Svalbard Radar, the SOUZY radar and the Kjell Henriksen Observatory. After much speculation regarding the operational future of the SPEAR facility, UNIS has taken ownership of the system, with a 3 year research and operational grant from the Norwegian Research Council. The facility has a detailed and successful research history, with results having already been presented at international scientific conferences and appeared in 13 peer-review papers in international journals. Successful experiments have been carried out using both X and O mode polarisation in conjunction with both ground and space based instrumentation. Additionally, the operational frequency the facility (4.45 - 5.825 MHz) means that its scientific capabilities will increase towards the next solar activity maximum in 2012. Future plans, both experimentally and logistically will be discussed in additional to possibilities for future experimental collaborations

  12. Cell response to quasi-monochromatic light with different coherence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Budagovsky, A V; Solovykh, N V; Budagovskaya, O N

    The problem of the light coherence effect on the magnitude of the photoinduced cell response is discussed. The origins of ambiguous interpretation of the known experimental results are considered. Using the biological models, essentially differing in anatomy, morphology and biological functions (acrospires of radish, blackberry microsprouts cultivated in vitro, plum pollen), the effect of statistical properties of quasi-monochromatic light (λ{sub max} = 633 nm) on the magnitude of the photoinduced cell response is shown. It is found that for relatively low spatial coherence, the cell functional activity changes insignificantly. The maximal enhancement of growing processes (stimulating effect) is observed whenmore » the coherence length L{sub coh} and the correlation radius r{sub cor} are greater than the cell size, i.e., the entire cell fits into the field coherence volume. In this case, the representative indicators (germination of seeds and pollen, the spears length) exceeds those of non-irradiated objects by 1.7 – 3.9 times. For more correct assessment of the effect of light statistical properties on photocontrol processes, it is proposed to replace the qualitative description (coherent – incoherent) with the quantitative one, using the determination of spatial and temporal correlation functions and comparing them with the characteristic dimensions of the biological structures, e.g., the cell size. (biophotonics)« less

  13. NRL SSD Research Achievements: 19601970. Volume 1

    DTIC Science & Technology

    2015-10-30

    radio sources between declinations +10 and -20,” Mills, B.Y., Slee O.B., Hill, E.R. 1958, Australian J. Phys., 11 , 360-387 12. “SPEAR: Small Payload... 11 . SPONSOR / MONITOR’S REPORT NUMBER(S) 12. DISTRIBUTION / AVAILABILITY STATEMENT 13. SUPPLEMENTARY NOTES 14. ABSTRACT 15. SUBJECT TERMS 16...from a tour-de-force lunar occultation rocket experiment; and the First Detection of X-Ray Pulsations from the Crab Pulsar that matched the radio

  14. 50 CFR 640.22 - Gear and diving restrictions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE SPINY LOBSTER FISHERY OF THE GULF OF MEXICO AND SOUTH... spiny lobster may not be taken in the EEZ with a spear, hook, or similar device, or gear containing such devices. In the EEZ, the possession of a speared, pierced, or punctured spiny lobster is prima facie...

  15. 50 CFR 640.22 - Gear and diving restrictions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE SPINY LOBSTER FISHERY OF THE GULF OF MEXICO AND SOUTH... spiny lobster may not be taken in the EEZ with a spear, hook, or similar device, or gear containing such devices. In the EEZ, the possession of a speared, pierced, or punctured spiny lobster is prima facie...

  16. An alternative estimation of the RF-enhanced plasma temperature during SPEAR artificial heating experiments: Early results

    NASA Astrophysics Data System (ADS)

    Vickers, H.; Baddeley, L.

    2011-11-01

    RF heating of the F region plasma at high latitudes has long been known to produce electron temperature increases that can vary from tens to hundreds of percent above the background, unperturbed level. In contrast, artificial ionospheric modification experiments conducted using the Space Plasma Exploration by Active Radar (SPEAR) heating facility on Svalbard have often failed to produce obvious enhancements in the electron temperatures when measured using the European Incoherent Scatter Svalbard radar (ESR), colocated with the heater. Contamination of the ESR ion line spectra by the zero-frequency purely growing mode (PGM) feature is known to persist at varying amplitudes throughout SPEAR heating, and such spectral features can lead to significant temperature underestimations when the incoherent scatter spectra are analyzed using conventional methods. In this study, we present the first results of applying a recently developed technique to correct the PGM-contaminated spectra to SPEAR-enhanced ESR spectra and derive an alternative estimate of the SPEAR-heated electron temperature. We discuss how the effectiveness of the spectrum corrections can be affected by the data variance, estimated over the integration period. The subsequent electron temperatures, inferred from corrected spectra, range from a few tens to a few hundred Kelvin above the average background temperature. These temperatures are found to be in reasonable agreement with the theoretical “enhanced” temperature, calculated for the peak of the stationary temperature perturbation profile, when realistic absorption effects are accounted for.

  17. SPEAR-induced field-aligned irregularities observed from bi-static HF radio scattering in the polar ionosphere

    NASA Astrophysics Data System (ADS)

    Blagoveshchenskaya, N. F.; Borisova, T. D.; Kornienko, V. A.; Kalishin, A. S.; Robinson, T. R.; Yeoman, T. K.; Wright, D. M.; Baddeley, L. J.

    2009-01-01

    Experimental results from SPEAR HF heating experiments in the polar ionosphere are examined. Bi-static scatter measurements of HF diagnostic signals were carried out on the Pori (Finland)-SPEAR-St. Petersburg path at operational frequencies of 11,755 and 15,400 kHz and the London-SPEAR-St. Petersburg path at frequencies of 12,095 and 17,700 kHz, using a Doppler spectral method. The SPEAR HF heating facility generates heater-induced artificial field-aligned small-scale irregularities (AFAIs), which can be detected by HF diagnostic bi-static radio scatter techniques at St. Petersburg at a distance of about 2000 km. In accordance with the Bragg condition, HF bi-static backscatters were sensitive to small-scale irregularities having spatial sizes of the order of 9-13 m across the geomagnetic field line. The properties and behaviour of AFAIs have been considered in the winter and summer seasons under quiet magnetic conditions and under various status of the polar ionosphere (the presence of "thick" and "thin" sporadic Es layers, different structures of the F2 layer). The experimental results obtained have shown that AFAIs can be excited in the F as well as in the E regions of the polar ionosphere. The excitation of a very intense wide-band spectral component with an abrupt increase in the spectral width up to 16-20 Hz has been found in the signals scattered from striations. Along with a wide-band component, a narrow-band spectral component can be also seen in the Doppler sonograms and in the average spectra of the signals scattered from the SPEAR-induced striations. AFAIs were excited even when the HF heater frequency was up to 0.5 MHz larger than the critical frequency. A simulation of the ray geometry for the diagnostic HF radio waves scattered from AFAIs in the polar ionosphere has been made for the geophysical conditions prevailing during experiments carried out in both the winter and summer seasons.

  18. Spear Phishing Attack Detection

    DTIC Science & Technology

    2011-03-24

    the insider amongst senior leaders of an organization [Mes08], the undercover detective within a drug cartel, or the classic secret agent planted in...to a mimicry attack that shapes the embedded malware to have a statistical distribution similar to "normal" or benign behavior. 2.3.1.3

  19. They Throw Spears: Reconciliation through Music

    ERIC Educational Resources Information Center

    Moore, Jane

    2013-01-01

    "They throw Spears" was written as part of the research for my PhD at the University of Sydney. The study was conducted in two primary schools: one in a remote area in the Northern Territory (NT) and one in an urban setting in Tasmania. It was conducted in 2009 and investigated Indigenous and non-Indigenous student, non-Indigenous…

  20. 76 FR 78258 - Valeant Pharmaceuticals International, Inc.; Analysis of Agreement Containing Consent Order to...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-16

    ....S.C. Sec. 18, and Section 5 of the FTC Act, as amended, 15 U.S.C. 45, in the market for tretinoin... rights to two pharmaceutical products, Refissa, a branded tretinoin emollient cream, and a generic tretinoin emollient cream, to Spear Pharmaceuticals (``Spear''), the company that owns both products. II...

  1. 50 CFR 660.360 - Recreational fishery-management measures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... authorized for recreational fishing are hook-and-line and spear. Spears may be propelled by hand or by... when the closure is in effect. The closure is not in effect at this time. This closure may be imposed... when the closure is in effect. The closure is not in effect at this time. This closure may be imposed...

  2. 50 CFR 660.360 - Recreational fishery-management measures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... authorized for recreational fishing are hook-and-line and spear. Spears may be propelled by hand or by... when the closure is in effect. The closure is not in effect at this time. This closure may be imposed... when the closure is in effect. The closure is not in effect at this time. This closure may be imposed...

  3. Asparagus Spears as a Model to Study Heteroxylan Biosynthesis during Secondary Wall Development

    PubMed Central

    Wu, Aimin; Picard, Kelsey; Lampugnani, Edwin R.; Cheetamun, Roshan; Beahan, Cherie; Cassin, Andrew; Lonsdale, Andrew; Doblin, Monika S.; Bacic, Antony

    2015-01-01

    Garden asparagus (Asparagus officinalis L.) is a commercially important crop species utilized for its excellent source of vitamins, minerals and dietary fiber. However, after harvest the tissue hardens and its quality rapidly deteriorates because spear cell walls become rigidified due to lignification and substantial increases in heteroxylan content. This latter observation prompted us to investigate the in vitro xylan xylosyltransferase (XylT) activity in asparagus. The current model system for studying heteroxylan biosynthesis, Arabidopsis, whilst a powerful genetic system, displays relatively low xylan XylT activity in in vitro microsomal preparations compared with garden asparagus therefore hampering our ability to study the molecular mechanism(s) of heteroxylan assembly. Here, we analyzed physiological and biochemical changes of garden asparagus spears stored at 4 °C after harvest and detected a high level of xylan XylT activity that accounts for this increased heteroxylan. The xylan XylT catalytic activity is at least thirteen-fold higher than that reported for previously published species, including Arabidopsis and grasses. A biochemical assay was optimized and up to seven successive Xyl residues were incorporated to extend the xylotetraose (Xyl4) acceptor backbone. To further elucidate the xylan biosynthesis mechanism, we used RNA-seq to generate an Asparagus reference transcriptome and identified five putative xylan biosynthetic genes (AoIRX9, AoIRX9-L, AoIRX10, AoIRX14_A, AoIRX14_B) with AoIRX9 having an expression profile that is distinct from the other genes. We propose that Asparagus provides an ideal biochemical system to investigate the biochemical aspects of heteroxylan biosynthesis and also offers the additional benefit of being able to study the lignification process during plant stem maturation. PMID:25894575

  4. Hot-fill pasteurization of cucumber pickle spears: an alternative to tunnel pasteurizers

    USDA-ARS?s Scientific Manuscript database

    For commercial production of acidified vegetable products, thermal processes (71°C to 74°C for 10 min to 15 min) are typically done using a tunnel pasteurizer. To reduce energy costs and water usage, we developed a hot-fill method for pasteurization of cucumber pickle spears in 0.7 L (24 oz) jars. T...

  5. 50 CFR 660.360 - Recreational fishery-management measures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... authorized for recreational fishing are hook-and-line and spear. Spears may be propelled by hand or by... at § 660.70, subpart C, on dates when the closure is in effect. The closure is not in effect at this... coordinates at § 660.70, subpart C, on dates when the closure is in effect. The closure is not in effect at...

  6. 50 CFR 660.360 - Recreational fishery-management measures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... authorized for recreational fishing are hook-and-line and spear. Spears may be propelled by hand or by... at § 660.70, subpart C, on dates when the closure is in effect. The closure is not in effect at this... coordinates at § 660.70, subpart C, on dates when the closure is in effect. The closure is not in effect at...

  7. Indication of pesticide effects and recolonization in streams.

    PubMed

    Knillmann, Saskia; Orlinskiy, Polina; Kaske, Oliver; Foit, Kaarina; Liess, Matthias

    2018-07-15

    The agricultural use of pesticides leads to environmentally relevant pesticide concentrations that cause adverse effects on stream ecosystems. These effects on invertebrate community composition can be identified by the bio-indicator SPEAR pesticides . However, refuge areas have been found to partly confound the indicator. On the basis of three monitoring campaigns of 41 sites in Central Germany, we identified 11 refuge taxa. The refuge taxa, mainly characterized by dispersal-based resilience, were observed only nearby uncontaminated stream sections and independent of the level of pesticide pressure. Through incorporation of this information into the revised SPEAR pesticides indicator, the community structure specifically identified the toxic pressure and no longer depended on the presence of refuge areas. With regard to ecosystem functions, leaf litter degradation was predicted by the revised SPEAR pesticides and the median water temperature at a site (R 2  = 0.38, P = 0.003). Furthermore, we designed the bio-indicator SPEAR refuge to quantify the magnitude of general recolonization at a given stream site. We conclude that the taxonomic composition of aquatic invertebrate communities enables a specific indication of anthropogenic stressors and resilience of ecosystems. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. ecoSPEARS License Signing with Kelvin Manning

    NASA Image and Video Library

    2017-12-19

    NASA Kennedy Space Center's Associate Director Kelvin Manning, center, signs a license agreement with the President and CEO of ecoSPEARS, which allows the company to commercially sell a soil remediation technology developed by a research team at Kennedy. The technology, known as Sorbent Polymer Extraction And Remediation System, is designed to capture and remove polychlorinated biphenyls (PCBs) from contaminated sediments in waterways and wetlands.

  9. Concussion Nondisclosure During Professional Career Among a Cohort of Former National Football League Athletes.

    PubMed

    Kerr, Zachary Y; Register-Mihalik, Johna K; Kay, Melissa C; DeFreese, J D; Marshall, Stephen W; Guskiewicz, Kevin M

    2018-01-01

    Despite a focus on the incidence and effects of concussion, nondisclosure of sports-related concussions among retired players from the National Football League (NFL) has yet to be examined. Examine the prevalence of and factors associated with nondisclosure of sports-related concussions in former NFL athletes. Cross-sectional study; Level of evidence, 3. A sample of 829 former NFL players completed a general health survey. This historical cohort included players who had played before World War II to 2001. Respondents retrospectively recalled sports-related concussions that they sustained during their professional careers and whether at least one of these sports-related concussions was not reported to medical staff. We computed the prevalence of nondisclosure among those recalling sport-related concussions during their professional careers. Multivariable binomial regression estimated adjusted prevalence ratios (PR) with 95% confidence intervals (CIs) controlling for race/ethnicity, number of years played, primary position played, professional career concussion history, and playing era. Playing era was categorized by whether the majority of a player's career was before or after a 1976 rule change to limit contact ("spearing"). Overall, 417 (50.3%) respondents reported they had sustained a concussion and did not inform medical staff at least once during their professional playing career. Nonwhite respondents had a higher prevalence of nondisclosure than white/non-Hispanic respondents (adjusted PR = 1.19; 95% CI, 1.02-1.38). An interaction between professional career concussion history and playing era was also found ( P = .08). Compared with those in the pre-spearing rule change group with 1 or 2 concussions, all other groups had larger prevalences of nondisclosure (increases ranging from 41% to 153% in multivariable models). Across concussion strata, nondisclosure prevalence was generally higher in the post-spearing rule change group than the pre-spearing rule change group, with the largest differences found among those with 1 or 2 concussions or those with 3 or 4 concussions. A large proportion of former NFL players in this historical cohort reported at least one instance of not disclosing sports-related concussions to medical staff. Future research on concussion nondisclosure needs to identify mechanisms to improve football players' intentions to disclose concussion-related symptoms to health care providers and to equip health care providers with more effective strategies for timely identification of concussion.

  10. New insights on the wooden weapons from the Paleolithic site of Schöningen.

    PubMed

    Schoch, Werner H; Bigga, Gerlinde; Böhner, Utz; Richter, Pascale; Terberger, Thomas

    2015-12-01

    The Paleolithic site of Schöningen is famous for the earliest known, completely preserved wooden weapons. Here we present recent results of an ongoing analysis of the nine spears, one lance, a double pointed stick, and a burnt stick dating to the Holsteinian, c. 300 kyr. Macroscopic and microscopic analyses, as well as studies of thin sections, contribute to a better understanding of the manufacture of the wooden weapons. They were deposited in organic sediments at a former lakeshore among numerous bones of butchered horses. In general, the spears are extremely well-preserved and show no or little sign of taphonomic alteration, although some of the weapons are broken and parts were slightly moved, probably by water action. The excellent preservation conditions provide considerable information on the operational sequence of production. The hunters selected thin trunks of spruce or pine and initially stripped off the bark. Traces of cutting, scraping, and smoothing can be observed on the spear surfaces in detail. In the case of spear X, repeated use of the weapon is implied by re-sharpening of the tip. Analyses of wood anatomy provide information on climatic conditions and contribute to the better understanding of the development of the site. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. The European saber-toothed cat (Homotherium latidens) found in the "Spear Horizon" at Schöningen (Germany).

    PubMed

    Serangeli, Jordi; Van Kolfschoten, Thijs; Starkovich, Britt M; Verheijen, Ivo

    2015-12-01

    The 300,000 year old Lower Paleolithic site Schöningen 13 II-4 became world famous with the discovery of the oldest well-preserved and complete wooden spears. Through ongoing excavations, new archaeological discoveries of scientific importance are still being made from the same archaeological layer where the spears were found. In this context, remains of a rare carnivore species, the European saber-toothed cat (Homotherium latidens), were recovered. Here we present five teeth and one humerus fragment that are unambiguously from two individual saber-toothed cats. The humerus is a unique specimen; it shows evidence of hominin impacts and use as a percussor. The Homotherium remains from Schöningen are the best documented finds of this species in an archaeological setting and they are amongst the youngest specimens of Homotherium in Europe. The presence of this species as a carnivore competitor would certainly have impacted the lives of late Middle Pleistocene hominins. The discovery illustrates the possible day-to-day challenges that the Schöningen hominins would have faced and suggests that the wooden spears were not necessarily only used for hunting, but possibly also as a weapon for self-defense. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Aspect sensitive E- and F-region SPEAR-enhanced incoherent backscatter observed by the EISCAT Svalbard radar

    NASA Astrophysics Data System (ADS)

    Dhillon, R. S.; Robinson, T. R.; Yeoman, T. K.

    2009-01-01

    Previous studies of the aspect sensitivity of heater-enhanced incoherent radar backscatter in the high-latitude ionosphere have demonstrated the directional dependence of incoherent scatter signatures corresponding to artificially excited electrostatic waves, together with consistent field-aligned signatures that may be related to the presence of artificial field-aligned irregularities. These earlier high-latitude results have provided motivation for repeating the investigation in the different geophysical conditions that obtain in the polar cap ionosphere. The Space Plasma Exploration by Active Radar (SPEAR) facility is located within the polar cap and has provided observations of RF-enhanced ion and plasma line spectra recorded by the EISCAT Svalbard UHF incoherent scatter radar system (ESR), which is collocated with SPEAR. In this paper, we present observations of aspect sensitive E- and F-region SPEAR-induced ion and plasma line enhancements that indicate excitation of both the purely growing mode and the parametric decay instability, together with sporadic E-layer results that may indicate the presence of cavitons. We note consistent enhancements from field-aligned, vertical and also from 5° south of field-aligned. We attribute the prevalence of vertical scatter to the importance of the Spitze region, and of that from field-aligned to possible wave/irregularity coupling.

  13. The polar-ionosphere phenomena induced by high-power radio waves from the spear heating facility

    NASA Astrophysics Data System (ADS)

    Blagoveshchenskaya, N. F.; Borisova, T. D.; Kornienko, V. A.; Janzhura, A. S.; Kalishin, A. S.; Robinson, T. R.; Yeoman, T. K.; Wright, D. M.; Baddeley, L. J.

    2008-11-01

    We present the results of experimental studies of specific features in the behavior of small-scale artificial field-aligned irregularities (AFAIs) and the DM component in the spectra of stimulated electromagnetic emission (SEE). Analysis of experimental data shows that AFAIs in the polar ionosphere are generated under different background geophysical conditions (season, local time, the presence of sporadic layers in the E region, etc.). It is shown that AFAIs can be excited not only in the F region, but also in “thick” sporadic E s layers of the polar ionosphere. The AFAIs were observed in some cycles of heating when the HF heater frequency exceeded the critical frequency by 0.3-0.5 MHz. Propagation paths of diagnostic HF radio waves scattered by AFAIs were modelled for geophysical conditions prevailing during the SPEAR heating experiments. Two components, namely, a narrow-banded one with a Doppler-spectrum width of up to 2 Hz and a broadband one observed in a band of up to 20 Hz, were found in the sporadic E s layer during the AFAI excitation. Analysis of the SEE spectra shows that the behavior of the DM component in time is irregular, which is possibly due to strong variations in the critical frequency of the F 2 layer from 3.5 to 4.6 MHz. An interesting feature observed in the SPEAR heating experiments is that the generation of the DM component was similar to the excitation of AFAIs when the heater frequency was up to 0.5 MHz higher than the critical frequency.

  14. Female Partner Acceptance as a Predictor of Men's Readiness to Undergo Voluntary Medical Male Circumcision in Zambia: The Spear and Shield Project.

    PubMed

    Cook, Ryan; Jones, Deborah; Redding, Colleen A; Zulu, Robert; Chitalu, Ndashi; Weiss, Stephen M

    2016-11-01

    The World Health Organization has recommended the scale-up of voluntary medical male circumcision (VMMC) for HIV prevention in sub-Saharan Africa; however, men are often uninterested in undergoing VMMC. The Spear & Shield project enrolled 668 men and female partners from ten Zambian community health centers into parallel interventions promoting VMMC for HIV prevention or time-matched control conditions. A mediation model was utilized to examine the relationships between changes in women's acceptance of VMMC and men's readiness to undergo the procedure. Results demonstrated that, at 12 months post-intervention, a 5.9 % increase in the likelihood of undergoing VMMC among men in the experimental condition could be attributed to increased women's acceptance. From a public health perspective, involving women in VMMC promotion interventions such as the Spear & Shield project could significantly impact the demand for VMMC in Zambia.

  15. SPORT-SPEAR Mark III Electronics (Engineering Materials)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The Drawing List DL 135-678-00-RO and the drawings listed thereon provide the specifications for construction of the SPORT-SPEAR Mark III Electronics. SPORT stands for Smark Port. This device is an adapter for the SLAC BADC (Brilliant Analog to Digital Converter) providing up to 5 ports whereas the BADC and SPORT takes signals from experimental equipment and directs them to other equipment and micro computers for processing and storing. These units are housed in standard Camac crates.

  16. SPOROCYTELESS is a novel embryophyte-specific transcription repressor that interacts with TPL and TCP proteins in Arabidopsis.

    PubMed

    Chen, Guang-Hui; Sun, Jia-Ying; Liu, Man; Liu, Jie; Yang, Wei-Cai

    2014-12-20

    Germlines in plants are formed de novo during post-embryonic development, while little is known about the mechanism that controls this process. In Arabidopsis, the earliest gene controlling this process is SPOROCYTELESS (SPL). A decade ago, we showed that loss of SPL function abolished sporogenesis in both male and female organs of Arabidopsis. However, its function is unclear up to now. In this study, we showed that SPL belongs to a novel transcription repressor family specific in embryophyte, which consists of 173 members in the land plants so far. All of them contain a conserved SPL-motif in their N-terminal and an ethylene-responsive element binding factor-associated amphiphilic repression (EAR) motif in the C-terminal, therefore designated as SPL-like, EAR-containing proteins (SPEARs). Consistently, SPL acts as a transcriptional repressor in yeast and tobacco cells, and SPEAR proteins are able to form homodimer and/or heterodimer with each other in vitro. Furthermore, SPEARs interact with the TOPLESS (TPL) co-repressors via the EAR motif and TCP family transcription factors in yeast cells. Together, we propose that SPL and SPEARs most likely belong to a novel transcription repressor family in land plants which may play a variety of developmental roles in plants. Copyright © 2014 Institute of Genetics and Developmental Biology, Chinese Academy of Sciences, and Genetics Society of China. Published by Elsevier Ltd. All rights reserved.

  17. Two years of debilitating pain in a football spearing victim: slipping rib syndrome.

    PubMed

    Peterson, Laurie L; Cavanaugh, Daniel G

    2003-10-01

    Blunt chest trauma can occur in a variety of sports, and lead to rib fractures and less commonly known and diagnosed injuries. We report the case of a 14-yr-old student athlete who was speared (helmet tackled) in a practice scrimmage sustaining a painful injury that eluded diagnosis and treatment for more than 2 yr. The case history of pain treatments and radiological evaluations is presented. Ultimately, a definitive diagnosis of "slipping rib syndrome" was achieved through a simple clinical manipulation (the hooking maneuver), combined with a history of symptomatic relief provided with costochondral blockade. Surgical resection of the slipping rib provided total resolution of the problem. Very few clinicians are aware either of the syndrome or the maneuver used to diagnose this condition. Although spearing has been outlawed in American football for years, it remains a commonplace occurrence, and sports physicians should be aware of the potential consequences to the victim as well as those to the perpetrator.

  18. An intercomparison of tropical cyclone best-track products for the southwest Pacific

    NASA Astrophysics Data System (ADS)

    Magee, Andrew D.; Verdon-Kidd, Danielle C.; Kiem, Anthony S.

    2016-06-01

    Recent efforts to understand tropical cyclone (TC) activity in the southwest Pacific (SWP) have led to the development of numerous TC databases. The methods used to compile each database vary and are based on data from different meteorological centres, standalone TC databases and archived synoptic charts. Therefore the aims of this study are to (i) provide a spatio-temporal comparison of three TC best-track (BT) databases and explore any differences between them (and any associated implications) and (ii) investigate whether there are any spatial, temporal or statistical differences between pre-satellite (1945-1969), post-satellite (1970-2011) and post-geostationary satellite (1982-2011) era TC data given the changing observational technologies with time. To achieve this, we compare three best-track TC databases for the SWP region (0-35° S, 135° E-120° W) from 1945 to 2011: the Joint Typhoon Warning Center (JTWC), the International Best Track Archive for Climate Stewardship (IBTrACS) and the Southwest Pacific Enhanced Archive of Tropical Cyclones (SPEArTC). The results of this study suggest that SPEArTC is the most complete repository of TCs for the SWP region. In particular, we show that the SPEArTC database includes a number of additional TCs, not included in either the JTWC or IBTrACS database. These SPEArTC events do occur under environmental conditions conducive to tropical cyclogenesis (TC genesis), including anomalously negative 700 hPa vorticity (VORT), anomalously negative vertical shear of zonal winds (VSZW), anomalously negative 700 hPa geopotential height (GPH), cyclonic (absolute) 700 hPa winds and low values of absolute vertical wind shear (EVWS). Further, while changes in observational technologies from 1945 have undoubtedly improved our ability to detect and monitor TCs, we show that the number of TCs detected prior to the satellite era (1945-1969) are not statistically different to those in the post-satellite era (post-1970). Although data from pre-satellite and pre-geostationary satellite periods are currently inadequate for investigating TC intensity, this study suggests that SPEArTC data (from 1945) may be used to investigate long-term variability of TC counts and TC genesis locations.

  19. Do observed levels of exploitation from consumption-oriented and trophy-oriented fisheries reduce relative stock densities of Muskellunge below target levels in northern Wisconsin?

    USGS Publications Warehouse

    Faust, Matthew D.; Hansen, Michael J.

    2017-01-01

    Muskellunge anglers desire to catch large fish, and release rates by recreational anglers often approach 100% (Isermann et al. 2011). Muskellunge are also a culturally significant fish for Chippewa tribes and support a subsistence spearing fishery in Wisconsin’s Ceded Territory (Erickson 2007). Although Muskellunge populations within the state’s Ceded Territory are exposed to both angling and spearing fishery exploitation, Faust and Hansen (2016) suggested that under certain conditions (e.g., high minimum length limits (MLL) and low spearing exploitation) Muskellunge fisheries with disparate motivations could coexist (i.e., sufficient numbers of large individuals remained despite harvest from consumptive fishery), but noted that larger declines in trophy Muskellunge abundance were predicted at lower MLLs (e.g., 102-cm). Fisheries managers with the Wisconsin Department of Natural Resources (WDNR) wished to further understand how specific relative stock densities (RSD), used by the WDNR to define and monitor trophy Muskellunge fisheries, are reduced at exploitation rates commonly experienced by populations in northern Wisconsin. Similarly, understanding how trophy Muskellunge abundance may have declined under the previous statewide MLL (i.e., 86-cm) at these levels of exploitation was also desired. Thus, our objectives were to 1) determine if observed levels of angling and spearing exploitation reduced predicted RSD indices below thresholds used by the WDNR to define trophy Muskellunge fisheries for three typical Muskellunge growth potentials in northern Wisconsin across a variety of MLLs; and 2) quantify how numbers of trophy Muskellunge declined under an 86-cm MLL at observed levels of exploitation.

  20. First observations of SPEAR-induced topside and bottomside sporadic E layer heating observed using the EISCAT Svalbard and SuperDARN radars

    NASA Astrophysics Data System (ADS)

    Baddeley, L. J.; Haggstrøm, I.; Yeoman, T. K.; Rietveld, M.

    2012-01-01

    We present the first observations of heater-induced simultaneous topside and bottomside sporadic E layer enhancements at very high latitudes (78.15°N) using the Space Plasma Exploration by Active Radar (SPEAR) heating facility and the European Incoherent Scatter (EISCAT) Svalbard Radar. During the experiment the SPEAR heating facility was transmitting with O-mode polarization in a field-aligned direction with a constant effective radiated power of ˜16 MW. Results show distinct heater-induced enhancements in both the ion and plasma line spectra. The plasma line enhancements are observed at the SPEAR heater frequency of 4.45 MHz. The plasma line observations represent the highest spatial resolution data (100 m) obtained of such heater-induced enhancements and indicate simultaneous enhancements at both the topside and bottomside of the layer, respectively (located at ˜107.5 and 109 km altitude, respectively). It is postulated that the results represent evidence of O- to Z-mode conversion of the heater wave occurring at the bottom of the E layer, allowing propagation through the layer resulting in simultaneous topside enhancements. The Z-mode enhancements are observed outside the Spitze angle, which is thought to be a result of field-aligned irregularities causing an increase in angular extent of the observations. Additional data from the Super Dual Auroral Radar Network (SuperDARN) HF Finland radar are also shown, which indicate that upon a thinning of the sporadic E layer, the heater beam propagated into the F region, where it induced artificial field-aligned irregularities.

  1. Paranormal experience in a medico-swimming rescue: a case study.

    PubMed

    Avramidis, Stathis

    2013-06-01

    This study looks at the case of a 20-year-old fisherman, who was speared in the head, the spear entering at his jaw and protruding from the top of his scull, while he was swimming unaccompanied; he was rescued, admitted to the intensive care unit for an operation, remained in a coma for a few days and then had a full recovery. About 10 days before the rescue, he had visited a monk who, intuited and functioning as channel of the divine spirit, had told him that he 'should not be afraid of anything', rubbing the top of his scull and his jaw exactly at the points through which the 40-inch spear passed. After the incident, the monk prescience again the exact day on which he would recover from the coma. It is concluded that the survival of the fisherman can be attributed to a paranormal event. The monk's prescience permit the assumption that a divine spirit was pervasive throughout the universe and present in this life-threatening situation, endeavouring to assist the lifeguard, the neurosurgeons and the young fisherman.

  2. Multi-tip nano-prisms: Controlled growth and emission enhancement properties

    NASA Astrophysics Data System (ADS)

    Liu, Ming; Meng, Cong; Xue, Zheng-Hong; Xiong, Xiang; Shu, Da-Jun; Peng, Ru-Wen; Wu, Qiang; Hu, Zheng; Wang, Mu

    2013-10-01

    We report here the experimental observations that the tip topography of ZnO nano-prisms sensitively depends on the percentage of oxygen in the flux of the carrying gas in vapor growth. At a relatively high oxygen concentration, a number of thin filaments can be nucleated atop nano-prisms, forming a unique fish-spear-like multi-tip morphology. The length and density of the “spear tines” depend on the flux of the carrying gas. The field emission properties of the nanorod array with different tip morphology are investigated. The structures with longer and denser spear tines possess lower turn-on electric field and higher electric current density. The cathodoluminescence properties of the ZnO nano-prisms have also been studied. The luminescence related to defects in multi-tip nano-prisms possesses the strongest intensity, and the nanorod without any tine structure possesses the lowest defect luminescence intensity. The intrinsic luminescence of ZnO around 385 nm, however, has the opposite tendency. We suggest that our observation is inspiring in optimizing the emission properties of the nanowire devices.

  3. Magnetron sputtering based direct fabrication of three dimensional CdTe hierarchical nanotrees exhibiting stable superhydrophobic property

    NASA Astrophysics Data System (ADS)

    Luo, Bingwei; Deng, Yuan; Wang, Yao; Shi, Yongming; Cao, Lili; Zhu, Wei

    2013-09-01

    Three dimensional CdTe hierarchical nanotrees are initially prepared by a simple one-step magnetron sputtering method without any templates or additives. The CdTe hierarchical nanotrees are constructed by the spear-like vertical trunks and horizontal branches with the diameters of about 100 nm at bottom and became cuspidal on the top. The particular nanostructure imparts these materials superhydrophobic property, and this property can be preserved after placing in air for 90 days, and is stable even after the ultraviolet light and X-ray irradiation, respectively. This study provides a simple strategy to achieve superhydrophobic properties for CdTe materials at lower temperature, which opens a new potential for CdTe solar cell with self-cleaning property.

  4. Parasitic Cavities Losses in SPEAR-2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sands, Matt

    2016-12-19

    In PEP the large number of particles in a bunch, together with the small bunch length, may cause grievous energy loss from the beam to parasitic modes in the accelerating cavities. I have recently tried to estimate the parasitic cavity in PEP, based on a paper of Keil and I have obtained the result that the loss to parasitic modes will be about 10 MeV per particle per revolution for a bunch length of about 10 cm. In this note, I bring together some of the considerations that might bear on an experimental investigation of the loss using SPEAR-2.

  5. A Computer-Based Visual Analog Scale,

    DTIC Science & Technology

    1992-06-01

    34 keys on the computer keyboard or other input device. The initial position of the arrow is always in the center of the scale to prevent biasing the...3 REFERENCES 1. Gift, A.G., "Visual Analogue Scales: Measurement of Subjective Phenomena." Nursing Research, Vol. 38, pp. 286-288, 1989. 2. Ltmdberg...3. Menkes, D.B., Howard, R.C., Spears, G.F., and Cairns, E.R., "Salivary THC Following Cannabis Smoking Correlates With Subjective Intoxication and

  6. Digital Modeling and Testing Research on Digging Mechanism of Deep Rootstalk Crops

    NASA Astrophysics Data System (ADS)

    Yang, Chuanhua; Xu, Ma; Wang, Zhoufei; Yang, Wenwu; Liao, Xinglong

    The digital model of the laboratory bench parts of digging deep rootstalk crops were established through adopting the parametric model technology based on feature. The virtual assembly of the laboratory bench of digging deep rootstalk crops was done and the digital model of the laboratory bench parts of digging deep rootstalk crops was gained. The vibrospade, which is the key part of the laboratory bench of digging deep rootstalk crops was simulated and the movement parametric curves of spear on the vibrospade were obtained. The results show that the spear was accorded with design requirements. It is propitious to the deep rootstalk.

  7. Quantitation and bitter taste contribution of saponins in fresh and cooked white asparagus (Asparagus officinalis L.).

    PubMed

    Dawid, Corinna; Hofmann, Thomas

    2014-02-15

    A sensitive HPLC-MS/MS method was developed enabling the simultaneous quantification of bitter-tasting mono- and bidesmosidic saponins in fresh and processed asparagus (Asparagus officinalis L.). Based on quantitative data and bitter taste recognition thresholds, dose-over-threshold factors were determined for the first time to determine the bitter impact of the individual saponins. Although 3-O-[α-L-rhamnopyranosyl-(1→2)-α-L-rhamnopyranosyl-(1 → 4)-β-D-glucopyranosyl]-(25R/S)-spirost-5-ene-3β-ol was found based on dose-over-threshold factors to be the predominant bitter saponin in raw asparagus spears, 3-O-[α-L-rhamnopyranosyl-(1 → 2)-{α-L-rhamnopyranosyl-(1 → 4)}-β-D-glucopyranosyl]-26-O-[β-D-glucopyranosyl]-(25R)-22-hydroxyfurost-5-ene-3β,26-diol, 3-O-[α-L-rhamnopyranosyl-(1 → 2)-{α-L-rhamnopyranosyl-(1 → 4)}-β-D-glucopyranosyl]-26-O-[β-D-glucopyranosyl]-(25S)-22-hydroxyfurost-5-ene-3β,26-diol, and (25R)- and (25S)-furost-5-en-3β,22,26-triol-3-O-[α-L-rhamnopyranosyl-(1 → 4)-β-D-glucopyranoside]-26-O-β-D-glucopyranoside were found as key bitter contributors after cooking. Interestingly, the monodesmosidic saponins 5a/b were demonstrated for the first time to be the major contributor to the bitter taste of fresh asparagus spears, while the bidesmosides 1a/b and 2a/b may be considered the primary determinants for the bitter taste of cooked asparagus. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Engineering of Fast and Robust Adaptive Control for Fixed-Wing Unmanned Aircraft

    DTIC Science & Technology

    2017-06-01

    12.6volts) lithium polymer batteries wired in parallel. The remaining cargo space was used for accommodating the Pixhawk autopilot. 33 Figure 4.3...was achievable under four hours of build time. 4.4.1 Spear Specifications • weight without battery : 1.45 lbs (658 g) • center of gravity: 3 – 3.5” (76...motor: 425 sized, 1200 kv minimum • prop: 9 x 4.5 CW (reverse) prop • electronic speed control (ESC): 30 amp minimum • battery : (2) 2200 mAH 12.6 volt

  9. Design and Evaluation of a Clock Multiplexing Circuit for the SSRL Booster Accelerator Timing System - Oral Presentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Araya, Million

    2015-08-25

    SPEAR3 is a 234 m circular storage ring at SLAC’s synchrotron radiation facility (SSRL) in which a 3 GeV electron beam is stored for user access. Typically the electron beam decays with a time constant of approximately 10hr due to electron lose. In order to replenish the lost electrons, a booster synchrotron is used to accelerate fresh electrons up to 3GeV for injection into SPEAR3. In order to maintain a constant electron beam current of 500mA, the injection process occurs at 5 minute intervals. At these times the booster synchrotron accelerates electrons for injection at a 10Hz rate. A 10Hzmore » 'injection ready' clock pulse train is generated when the booster synchrotron is operating. Between injection intervalswhere the booster is not running and hence the 10 Hz ‘injection ready’ signal is not present-a 10Hz clock is derived from the power line supplied by Pacific Gas and Electric (PG&E) to keep track of the injection timing. For this project I constructed a multiplexing circuit to 'switch' between the booster synchrotron 'injection ready' clock signal and PG&E based clock signal. The circuit uses digital IC components and is capable of making glitch-free transitions between the two clocks. This report details construction of a prototype multiplexing circuit including test results and suggests improvement opportunities for the final design.« less

  10. Design and Evaluation of a Clock Multiplexing Circuit for the SSRL Booster Accelerator Timing System - Final Paper

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Araya, Million

    2015-08-21

    SPEAR3 is a 234 m circular storage ring at SLAC’s synchrotron radiation facility (SSRL) in which a 3 GeV electron beam is stored for user access. Typically the electron beam decays with a time constant of approximately 10hr due to electron lose. In order to replenish the lost electrons, a booster synchrotron is used to accelerate fresh electrons up to 3GeV for injection into SPEAR3. In order to maintain a constant electron beam current of 500mA, the injection process occurs at 5 minute intervals. At these times the booster synchrotron accelerates electrons for injection at a 10Hz rate. A 10Hzmore » 'injection ready' clock pulse train is generated when the booster synchrotron is operating. Between injection intervals-where the booster is not running and hence the 10 Hz ‘injection ready’ signal is not present-a 10Hz clock is derived from the power line supplied by Pacific Gas and Electric (PG&E) to keep track of the injection timing. For this project I constructed a multiplexing circuit to 'switch' between the booster synchrotron 'injection ready' clock signal and PG&E based clock signal. The circuit uses digital IC components and is capable of making glitch-free transitions between the two clocks. This report details construction of a prototype multiplexing circuit including test results and suggests improvement opportunities for the final design.« less

  11. Multi-indicator Evaluation System for Broadsword, Rod, Sword and Spear Athletes Based on Analytic Hierarchy Process

    NASA Astrophysics Data System (ADS)

    Luo, Lin

    2017-08-01

    In the practical selection of Wushu athletes, the objective evaluation of the level of athletes lacks sufficient technical indicators and often relies on the coach’s subjective judgments. It is difficult to accurately and objectively reflect the overall quality of the athletes without a fully quantified indicator system, thus affecting the level improvement of Wushu competition. The analytic hierarchy process (AHP) is a systemic analysis method combining quantitative and qualitative analysis. This paper realizes structured, hierarchized and quantified decision-making process of evaluating broadsword, rod, sword and spear athletes in the AHP. Combing characteristics of the athletes, analysis is carried out from three aspects, i.e., the athlete’s body shape, physical function and sports quality and 18 specific evaluation indicators established, and then combining expert advice and practical experience, pairwise comparison matrix is determined, and then the weight of the indicators and comprehensive evaluation coefficient are obtained to establish the evaluation model for the athletes, thus providing a scientific theoretical basis for the selection of Wushu athletes. The evaluation model proposed in this paper has realized the evaluation system of broadsword, rod, sword and spear athletes, which has effectively improved the scientific level of Wushu athletes selection in practical application.

  12. Bone taphonomy of the Schöningen "Spear Horizon South" and its implications for site formation and hominin meat provisioning.

    PubMed

    Starkovich, Britt M; Conard, Nicholas J

    2015-12-01

    This paper presents the faunal remains from the new excavation area at the Lower Paleolithic site of Schöningen. The focus of the study is on the southern extension of the main find horizon (Spear Horizon South), which includes the layer that yielded the famous Schöningen spears (13 II-4). Taxonomic data corroborate previous studies, that hominins primarily hunted Equus mosbachensis, a large Pleistocene horse. Equid body part representation at the site suggests that the animals were hunted and butchered locally. There is no evidence for density-mediated attrition in the assemblage. Weathering damage is uncommon, though there is ample evidence that carnivores had access to the bone. Carnivore bite sizes were measured and compared to experimental data provided by previous authors. Based on relationships between bite size and carnivore behavior and body size, we conclude that the primary modifying agents were large carnivores (i.e., wolves or saber-toothed cats). Previous studies show that carnivores often had secondary access to the remains, after hominins. Cut marks are commonly arranged haphazardly on the bones. This may indicate that multiple hominins participated in the butchery of horse skeletons, or that they were butchered over the course of hours or days. Cut marks on axial elements are more "orderly," which probably reflects the physical logistics of orienting one's body in relation to a large carcass. These data differ from sites formed by Middle and Upper Paleolithic hominins, which might suggest that in later times, a system of organized meat provisioning was already in place. Taken together, the faunal evidence from the Spear Horizon South indicates that late Lower Paleolithic hominins using the site understood the behaviors of different prey species, hunted socially to take down large game, and successfully competed with large carnivores on the landscape for primary access to ungulate remains. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Lattice Calibration with Turn-By-Turn BPM Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Xiaobiao; /SLAC; Sebek, James

    2012-07-02

    Turn-by-turn beam position monitor (BPM) data from multiple BPMs are fitted with a tracking code to calibrate magnet strengths in a manner similar to the well known LOCO code. Simulation shows that this turn-by-turn method can be a quick and efficient way for optics calibration. The method is applicable to both linacs and ring accelerators. Experimental results for a section of the SPEAR3 ring is also shown.

  14. Spear-anvil point-contact spectroscopy in pulsed magnetic fields

    NASA Astrophysics Data System (ADS)

    Arnold, F.; Yager, B.; Kampert, E.; Putzke, C.; Nyéki, J.; Saunders, J.

    2013-11-01

    We describe a new design and experimental technique for point-contact spectroscopy in non-destructive pulsed magnetic fields up to 70 {T}. Point-contact spectroscopy uses a quasi-dc four-point measurement of the current and voltage across a spear-anvil point-contact. The contact resistance could be adjusted over three orders of magnitude by a built-in fine pitch threaded screw. The first measurements using this set-up were performed on both single-crystalline and exfoliated graphite samples in a 150 {ms}, pulse length 70 {T} coil at 4.2 {K} and reproduced the well known point-contact spectrum of graphite and showed evidence for a developing high field excitation above 35 T, the onset field of the charge-density wave instability in graphite.

  15. HgCdTe Photoconductive Mixers for 2-8 THz

    NASA Technical Reports Server (NTRS)

    Betz, A. L.; Boreiko, R. T.; Sivananthan, S.; Ashokan, R.

    2001-01-01

    Heterodyne spectroscopy has been taken to wavelengths as short as 63 micrometers with Schottky-diode mixers. Schottkys, however, are relatively insensitive compared to superconducting mixers such as the hot-electron microbolometer (HEB), which has an effective quantum efficiency of 3% at 120 micrometers (2.5 THz). Although HEB sensitivities are bound to improve, there will always be losses associated with antenna coupling of radiation into sub-micron size devices. Another approach to far infrared (FIR) mixer design is to use a photoconductive device which can be made much larger than a wavelength, and thus act as its own antenna. For example, HgCdTe photodiodes have been used as mixers in the lambda = 10 micrometers band for over 25 years, with sensitivities now only a factor of 2 from the quantum-noise-limit. HgCdTe can also be applied at FIR wavelengths, but surprisingly little work has been done to date. The exception is the pioneering work of Spears and Kostiuk and Spears, who developed HgCdTe photomixers for the 20-120 micrometer region. The spectral versatility of the HgCdTe alloy is well recognized for wavelengths as long as 8-20 micrometers. What is not so recognized, however, is that theoretically there is no long wavelength limit for appropriately composited HgCdTe. Although Spears successfully demonstrated a photoconductive response from HgCdTe at 120 micrometers, this initial effort was apparently never followed up, in part because of the difficulty of controlling the HgCdTe alloy composition with liquid-phase-epitaxy (LPE) techniques. With the availability of precise molecular-beam-epitaxy (MBE) since the early 1990's, it is now appropriate to reconsider HgCdTe for detector applications longward of lambda = 20 micrometers. We recently initiated an effort to fabricate detectors and mixers using II-VI materials for FIR wavelengths. Of particular interest are device structures called superlattices, which offer a number of advantages for high sensitivity direct detectors and very long wavelength heterodyne mixers.

  16. Symbolics of the constellations of sagittarius and centaurus in russian traditional culture

    NASA Astrophysics Data System (ADS)

    Bagdasarov, R.

    2001-12-01

    Centaurus falls into the category of 'imaginary animals'. The Russian tradition used not only the symbol Sgr (a result of its acquaintance with the circle of Zodiac), but also the symbol Cen, which fact, as we shall demonstrate, is an evidence of certain mythological-astronomical conceptions. Both the constellations Sagittarius (Sgr) and Centaurus (Cen) are usually represented as versions of the picture of a fantastic being, a Centaur, shaped as man from head to waist, and as an animal, mostly, a horse, from waist down. 'Centaurus' (from the Greek word kev (or kevw)) for 'kill' and o, for 'bull') means 'bull killer', and is probably related to the opposition of the zodiacal constellations Taurus and Sagittarius. When the latter begins to rise on to the night sky, the former disappears completely from view. Sagittarius is represented at ancient monuments related to astronomy as a centaur holding a bow and pointing at certain stars. The constellation of Centaurus is also symbolised by a centaur, but holding not a bow, but a staff or a spear in one hand and an 'animal of sacrifice' in the other (Higinus, Astronomica, III, 37, 1; Chernetsov, 1975, Figure 1). The attributes stand for the Peliases Spear (The Mithological Dictionary, 1991), depicted in astrological maps as The Spear of Centaurus1, The Wolf (Lupus), the Panther or the Beast (Flammarion, 1994).

  17. Effects of consumption-oriented versus trophy-oriented fisheries on Muskellunge population size structure in northern Wisconsin

    USGS Publications Warehouse

    Faust, Matthew D.; Hansen, Michael J.

    2016-01-01

    To determine whether a consumption-oriented fishery was compatible with a trophy-oriented fishery for Muskellunge Esox masquinongy, we modeled effects of a spearing fishery and recreational angling fishery on population size structure (i.e., numbers of fish ≥ 102, 114, and 127 cm) in northern Wisconsin. An individual-based simulation model was used to quantify the effect of harvest mortality at currently observed levels of recreational angling and tribal spearing fishery exploitation, along with simulated increases in exploitation, for three typical growth potentials (i.e., low, moderate, and high) of Muskellunge in northern Wisconsin across a variety of minimum length limits (i.e., 71, 102, 114, and 127 cm). Populations with moderate to high growth potential and minimum length limits ≥ 114 cm were predicted to have lower declines in numbers of trophy Muskellunge when subjected to angling-only and mixed fisheries at observed and increased levels of exploitation, which suggested that fisheries with disparate motivations may be able to coexist under certain conditions such as restrictive length limits and low levels of exploitation. However, for most Muskellunge populations in northern Wisconsin regulated by a 102-cm minimum length limit, both angling and spearing fisheries may reduce numbers of trophy Muskellunge as larger declines were predicted across all growth potentials. Our results may be useful if Muskellunge management options in northern Wisconsin are re-examined in the future.

  18. 15 CFR 922.102 - Prohibited or otherwise regulated activities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Trade (Continued) NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE OCEAN AND..., including such devices known as Hawaiian slings, pole spears, arbalettes, pneumatic and spring-loaded...

  19. 15 CFR 922.102 - Prohibited or otherwise regulated activities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Trade (Continued) NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE OCEAN AND..., including such devices known as Hawaiian slings, pole spears, arbalettes, pneumatic and spring-loaded...

  20. Development of a Standard for the Health Hazard Assessment of Mechanical Shock and Repeated Impact in Army Vehicles, Phase 3, Pilot Tests.

    DTIC Science & Technology

    1995-05-01

    Hulshof , 1990; and Milby and Spear, 1974). Some studies focus on subjective symptoms of health problems, such as backache. Other studies 2 investigate...syndromes, rather than causing specific pathologies (Seidel and Heide, 1986; Dupuis and Zerlett, 1986; Hulshof and van Zanten, 1987). Although some...In: AGARD Conference Proceedings No.378 on Backache and Back Discomfort. Pozzuoli, Italy: NATO. 82 Boshuizen, H.C., Bongers, P.M. and Hulshof , C.T.J

  1. Seeing High Velocity Clouds and Turbulent Mixing Layers in the Ultraviolet: Predictions from Hydrodynamic Simulations

    NASA Astrophysics Data System (ADS)

    Shelton, Robin L.

    2018-06-01

    High velocity clouds (HVCs) and turbulent mixing layers (TMLs) emit light across a wide range of wavelengths. In order to aid in the detection of their ultraviolet emission, we predict the UV emission line intensities emitted by C II, C III, C IV, N II, N III, N IV, N V, O III, O IV, O V, O VI, Si II, Si III, and Si IV in a variety of simulated HVCs and TMLs. These predictions are based on detailed hydrodynamic simulations made with the FLASH code and employing non-equilibrium ionization calculations for carbon, nitrogen, oxygen, and silicon. The results are compared with FUSE and SPEAR/FIMS observations and with predictions from other models of hot/cool interfaces. We also present methods for scaling the results so that they can be applied to more or less dense environments.

  2. Volume-scalable high-brightness three-dimensional visible light source

    DOEpatents

    Subramania, Ganapathi; Fischer, Arthur J; Wang, George T; Li, Qiming

    2014-02-18

    A volume-scalable, high-brightness, electrically driven visible light source comprises a three-dimensional photonic crystal (3DPC) comprising one or more direct bandgap semiconductors. The improved light emission performance of the invention is achieved based on the enhancement of radiative emission of light emitters placed inside a 3DPC due to the strong modification of the photonic density-of-states engendered by the 3DPC.

  3. A broadband LED source in visible to short-wave-infrared wavelengths for spectral tumor diagnostics

    NASA Astrophysics Data System (ADS)

    Hayashi, Daiyu; van Dongen, Anne Marie; Boerekamp, Jack; Spoor, Sandra; Lucassen, Gerald; Schleipen, Jean

    2017-06-01

    Various tumor types exhibit the spectral fingerprints in the absorption and reflection spectra in visible and especially in near- to short-wave-infrared wavelength ranges. For the purpose of spectral tumor diagnostics by means of diffuse reflectance spectroscopy, we developed a broadband light emitting diode (LED) source consisting of a blue LED for optical excitation, Lu3Al5O12:Ce3+,Cr3+ luminescent garnet for visible to near infrared emissions, and Bismuth doped GeO2 luminescent glass for near-infrared to short-wave infrared emissions. It emits broad-band light emissions continuously in 470-1600 nm with a spectral gap at 900-1000 nm. In comparison to the currently available broadband light sources like halogen lamps, high-pressure discharge lamps and super continuum lasers, the light sources of this paper has significant advantages for spectral tissue diagnostics in high-spectral stability, improved light coupling to optical fibers, potential in low light source cost and enabling battery-drive.

  4. Shanidar 3 Neandertal rib puncture wound and paleolithic weaponry.

    PubMed

    Churchill, Steven E; Franciscus, Robert G; McKean-Peraza, Hilary A; Daniel, Julie A; Warren, Brittany R

    2009-08-01

    Since its discovery and initial description in the 1960s, the penetrating lesion to the left ninth rib of the Shanidar 3 Neandertal has been a focus for discussion about interpersonal violence and weapon technology in the Middle Paleolithic. Recent experimental studies using lithic points on animal targets suggest that aspects of weapon system dynamics can be inferred from the form of the bony lesions they produce. Thus, to better understand the circumstances surrounding the traumatic injury suffered by Shanidar 3, we conducted controlled stabbing experiments with replicas of Mousterian and Levallois points directed against the thoraces of pig carcasses. Stabs were conducted under both high and low kinetic energy conditions, in an effort to replicate the usual impact forces associated with thrusting spear vs. long-range projectile weapon systems, respectively. Analysis of the lesions produced in the pig ribs, along with examination of goat ribs subjected primarily to high kinetic energy stabs from an independent experiment, revealed consistent differences in damage patterns between the two conditions. In the case of Shanidar 3, the lack of major involvement of more than one rib, the lack of fracturing of the affected and adjacent ribs, and the lack of bony defects associated with the lesion (such as wastage, hinging, and radiating fracture lines) suggests that the weapon that wounded him was carrying relatively low kinetic energy. While accidental injury or attack with a thrusting spear or knife cannot absolutely be ruled out, the position, angulation, and morphology of the lesion is most consistent with injury by a low-mass, low-kinetic energy projectile weapon. Given the potential temporal overlap of Shanidar 3 with early modern humans in western Asia, and the possibility that the latter were armed with projectile weapon systems, this case carries more than simple paleoforensic interest.

  5. Safe Passage Data Analysis: Interim Report

    DOT National Transportation Integrated Search

    1993-04-01

    The purpose of this report is to describe quantitatively the costs and benefits of screener : proficiency evaluation and reporting systems (SPEARS) equipment, particularly computer-based : instruction (CBI) systems, compared to current methods of tra...

  6. Causal Cognition, Force Dynamics and Early Hunting Technologies

    PubMed Central

    Gärdenfors, Peter; Lombard, Marlize

    2018-01-01

    With this contribution we analyze ancient hunting technologies as one way to explore the development of causal cognition in the hominin lineage. Building on earlier work, we separate seven grades of causal thinking. By looking at variations in force dynamics as a central element in causal cognition, we analyze the thinking required for different hunting technologies such as stabbing spears, throwing spears, launching atlatl darts, shooting arrows with a bow, and the use of poisoned arrows. Our interpretation demonstrates that there is an interplay between the extension of human body through technology and expanding our cognitive abilities to reason about causes. It adds content and dimension to the trend of including embodied cognition in evolutionary studies and in the interpretation of the archeological record. Our method could explain variation in technology sets between archaic and modern human groups. PMID:29483885

  7. Determinants of residential mobility decisions: the role of government services in relation to other factors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Varady, D.P.

    This article is one of the first to test for the relative importance of concerns about public services in affecting residential mobility decisions over and beyond normal mobility factors. A secondary aim is to test for the validity of a residential mobility model formulated by Speare and associates. Multiple regression analysis was employed using 1974 to 1977 data from the longitudinal version of the Annual Housing Survey. Concerns about public services did not play a meaningful role in the analysis. This implies that efforts to hold middle-income residents in declining neighborhoods, through improved services, will not succeed. The results supportedmore » the Speare mobility model; housing satisfaction acted as an intermediary variable between background characteristics and mobility behavior. 30 references, 4 figures, 5 tables.« less

  8. The comparative hydrodynamics of rapid rotation by predatory appendages.

    PubMed

    McHenry, M J; Anderson, P S L; Van Wassenbergh, S; Matthews, D G; Summers, A P; Patek, S N

    2016-11-01

    Countless aquatic animals rotate appendages through the water, yet fluid forces are typically modeled with translational motion. To elucidate the hydrodynamics of rotation, we analyzed the raptorial appendages of mantis shrimp (Stomatopoda) using a combination of flume experiments, mathematical modeling and phylogenetic comparative analyses. We found that computationally efficient blade-element models offered an accurate first-order approximation of drag, when compared with a more elaborate computational fluid-dynamic model. Taking advantage of this efficiency, we compared the hydrodynamics of the raptorial appendage in different species, including a newly measured spearing species, Coronis scolopendra The ultrafast appendages of a smasher species (Odontodactylus scyllarus) were an order of magnitude smaller, yet experienced values of drag-induced torque similar to those of a spearing species (Lysiosquillina maculata). The dactyl, a stabbing segment that can be opened at the distal end of the appendage, generated substantial additional drag in the smasher, but not in the spearer, which uses the segment to capture evasive prey. Phylogenetic comparative analyses revealed that larger mantis shrimp species strike more slowly, regardless of whether they smash or spear their prey. In summary, drag was minimally affected by shape, whereas size, speed and dactyl orientation dominated and differentiated the hydrodynamic forces across species and sizes. This study demonstrates the utility of simple mathematical modeling for comparative analyses and illustrates the multi-faceted consequences of drag during the evolutionary diversification of rotating appendages. © 2016. Published by The Company of Biologists Ltd.

  9. The crystallography of hydride formation in zirconium: II. the δ → ɛ transformation

    NASA Astrophysics Data System (ADS)

    Cassidy, M. P.; Wayman, C. M.

    1980-12-01

    The phenomenological crystallographic theory of martensitic transformations has been applied to the transformation from δ (fcc) to ɛ (fct) zirconium hydride, using published lattice parameters. The habit plane, orientation relationship, lattice invariant shear, and interface characteristics were determined by transmission electron microscopy and diffraction. The shape strain was observed by interference microscopy. Good agreement between the predictions of the theory and the measured crystallography was obtained. The predicted and observed lattice invariant shear was twinning on 101. These twins which are found within alternating bands of hydride variants produce a herringbone morphology, and the bands produce a roof gable type of surface relief. For a given plate, the measured habit plane, twin plane, unique Bain contraction axis, and orientation relationship were mutually consistent with the respective predictions for a single variant. The magnitude of the lattice invariant shear was in excellent agreement with the predicted value. The interfaces separating the e hydride bands were found to be of two types, which alternated, often filling an entire grain. One of these, termed a spear interface, was found to be a twin plane, across which the twinned regions of the two bands “matched-up”. The other, termed an impingement interface, was found to have twin regions which did not “match-up”. This morphology can be explained as a pair of ɛ-hydride plates which share a spear interface. When two growing spears impinge, the resulting impingement interface is of the second type.

  10. Responses of mirror neurons in area F5 to hand and tool grasping observation

    PubMed Central

    Rochat, Magali J.; Caruana, Fausto; Jezzini, Ahmad; Escola, Ludovic; Intskirveli, Irakli; Grammont, Franck; Gallese, Vittorio; Rizzolatti, Giacomo

    2010-01-01

    Mirror neurons are a distinct class of neurons that discharge both during the execution of a motor act and during observation of the same or similar motor act performed by another individual. However, the extent to which mirror neurons coding a motor act with a specific goal (e.g., grasping) might also respond to the observation of a motor act having the same goal, but achieved with artificial effectors, is not yet established. In the present study, we addressed this issue by recording mirror neurons from the ventral premotor cortex (area F5) of two monkeys trained to grasp objects with pliers. Neuron activity was recorded during the observation and execution of grasping performed with the hand, with pliers and during observation of an experimenter spearing food with a stick. The results showed that virtually all neurons responding to the observation of hand grasping also responded to the observation of grasping with pliers and, many of them to the observation of spearing with a stick. However, the intensity and pattern of the response differed among conditions. Hand grasping observation determined the earliest and the strongest discharge, while pliers grasping and spearing observation triggered weaker responses at longer latencies. We conclude that F5 grasping mirror neurons respond to the observation of a family of stimuli leading to the same goal. However, the response pattern depends upon the similarity between the observed motor act and the one executed by the hand, the natural motor template. PMID:20577726

  11. Utility and safety of a novel surgical microscope laser light source

    PubMed Central

    Bakhit, Mudathir S.; Suzuki, Kyouichi; Sakuma, Jun; Fujii, Masazumi; Murakami, Yuta; Ito, Yuhei; Sugano, Tetsuo; Saito, Kiyoshi

    2018-01-01

    Objective Tissue injuries caused by the thermal effects of xenon light microscopes have previously been reported. Due to this, the development of a safe microscope light source became a necessity. A newly developed laser light source is evaluated regarding its effectiveness and safety as an alternative to conventional xenon light source. Methods We developed and tested a new laser light source for surgical microscopes. Four experiments were conducted to compare xenon and laser lights: 1) visual luminance comparison, 2) luminous and light chromaticity measurements, 3) examination and analysis of visual fatigue, and 4) comparison of focal temperature elevation due to light source illumination using porcine muscle samples. Results Results revealed that the laser light could be used at a lower illumination value than the xenon light (p < 0.01). There was no significant difference in visual fatigue status between the laser light and the xenon light. The laser light was superior to the xenon light regarding luminous intensity and color chromaticity. The focal temperature elevation of the muscle samples was significantly higher when irradiated with xenon light in vitro than with laser light (p < 0.01). Conclusion The newly developed laser light source is more efficient and safer than a conventional xenon light source. It lacks harmful ultraviolet waves, has a longer lifespan, a lower focal temperature than that of other light sources, a wide range of brightness and color production, and improved safety for the user’s vision. Further clinical trials are necessary to validate the impact of this new light source on the patient’s outcome and prognosis. PMID:29390016

  12. Performance Evaluation of 98 CZT Sensors for Their Use in Gamma-Ray Imaging

    NASA Astrophysics Data System (ADS)

    Dedek, Nicolas; Speller, Robert D.; Spendley, Paul; Horrocks, Julie A.

    2008-10-01

    98 SPEAR sensors from eV Products have been evaluated for their use in a portable Compton camera. The sensors have a 5 mm times 5 mm times 5 mm CdZnTe crystal and are provided together with a preamplifier. The energy resolution was studied in detail for all sensors and was found to be 6% on average at 59.5 keV and 3% on average at 662 keV. The standard deviations of the corresponding energy resolution distributions are remarkably small (0.6% at 59.5 keV, 0.7% at 662 keV) and reflect the uniformity of the sensor characteristics. For a possible outside use the temperature dependence of the sensor performances was investigated for temperatures between 15 and 45 deg Celsius. A linear shift in calibration with temperature was observed. The energy resolution at low energies (81 keV) was found to deteriorate exponentially with temperature, while it stayed constant at higher energies (356 keV). A Compton camera built of these sensors was simulated. To obtain realistic energy spectra a suitable detector response function was implemented. To investigate the angular resolution of the camera a 137Cs point source was simulated. Reconstructed images of the point source were compared for perfect and realistic energy and position resolutions. The angular resolution of the camera was found to be better than 10 deg.

  13. Passive lighting responsive three-dimensional integral imaging

    NASA Astrophysics Data System (ADS)

    Lou, Yimin; Hu, Juanmei

    2017-11-01

    A three dimensional (3D) integral imaging (II) technique with a real-time passive lighting responsive ability and vivid 3D performance has been proposed and demonstrated. Some novel lighting responsive phenomena, including light-activated 3D imaging, and light-controlled 3D image scaling and translation, have been realized optically without updating images. By switching the on/off state of a point light source illuminated on the proposed II system, the 3D images can show/hide independent of the diffused illumination background. By changing the position or illumination direction of the point light source, the position and magnification of the 3D image can be modulated in real time. The lighting responsive mechanism of the 3D II system is deduced analytically and verified experimentally. A flexible thin film lighting responsive II system with a 0.4 mm thickness was fabricated. This technique gives some additional degrees of freedom in order to design the II system and enable the virtual 3D image to interact with the real illumination environment in real time.

  14. Homogeneous free-form directional backlight for 3D display

    NASA Astrophysics Data System (ADS)

    Krebs, Peter; Liang, Haowen; Fan, Hang; Zhang, Aiqin; Zhou, Yangui; Chen, Jiayi; Li, Kunyang; Zhou, Jianying

    2017-08-01

    Realization of a near perfect homogeneous secondary emission source for 3D display is proposed and demonstrated. The light source takes advantage of an array of free-form emission surface with a specially tailored light guiding structure, a light diffuser and Fresnel lens. A seamless and homogeneous directional emission is experimentally obtained which is essential for a high quality naked-eye 3D display.

  15. Instrumentation, Control and Communication Systems for Sounding Rockets and Shuttle-Borne Experiments

    DTIC Science & Technology

    1991-07-02

    at the Plumbrook Station located in Sundusky, Ohio was conducted during November 1987 to confirm payload operation under vacuum and to calibrate the...DURATION STAFF TIM SDC, AZ SPIRIT-II 11/2/87 to O’Connor 11/6/87 VACUUM TEST Plumbrook SPEAR-I 11/3/87 to Wheeler Station , 11/6/87 & Sweeney Sandusky...reception by the ground stations , that signal also will be received in the payload and relayed to the ground stations . 2.5.2 Overview The LIFE I 17

  16. Spearhead Nanometric Field-Effect Transistor Sensors for Single-Cell Analysis.

    PubMed

    Zhang, Yanjun; Clausmeyer, Jan; Babakinejad, Babak; Córdoba, Ainara López; Ali, Tayyibah; Shevchuk, Andrew; Takahashi, Yasufumi; Novak, Pavel; Edwards, Christopher; Lab, Max; Gopal, Sahana; Chiappini, Ciro; Anand, Uma; Magnani, Luca; Coombes, R Charles; Gorelik, Julia; Matsue, Tomokazu; Schuhmann, Wolfgang; Klenerman, David; Sviderskaya, Elena V; Korchev, Yuri

    2016-03-22

    Nanometric field-effect-transistor (FET) sensors are made on the tip of spear-shaped dual carbon nanoelectrodes derived from carbon deposition inside double-barrel nanopipettes. The easy fabrication route allows deposition of semiconductors or conducting polymers to comprise the transistor channel. A channel from electrodeposited poly pyrrole (PPy) exhibits high sensitivity toward pH changes. This property is exploited by immobilizing hexokinase on PPy nano-FETs to give rise to a selective ATP biosensor. Extracellular pH and ATP gradients are key biochemical constituents in the microenvironment of living cells; we monitor their real-time changes in relation to cancer cells and cardiomyocytes. The highly localized detection is possible because of the high aspect ratio and the spear-like design of the nano-FET probes. The accurately positioned nano-FET sensors can detect concentration gradients in three-dimensional space, identify biochemical properties of a single living cell, and after cell membrane penetration perform intracellular measurements.

  17. Spearhead Nanometric Field-Effect Transistor Sensors for Single-Cell Analysis

    PubMed Central

    Córdoba, Ainara López; Ali, Tayyibah; Shevchuk, Andrew; Takahashi, Yasufumi; Novak, Pavel; Edwards, Christopher; Lab, Max; Gopal, Sahana; Chiappini, Ciro; Anand, Uma; Magnani, Luca; Coombes, R. Charles; Gorelik, Julia; Matsue, Tomokazu; Schuhmann, Wolfgang; Klenerman, David; Sviderskaya, Elena V.; Korchev, Yuri

    2016-01-01

    Nanometric field-effect-transistor (FET) sensors are made on the tip of spear-shaped dual carbon nanoelectrodes derived from carbon deposition inside double-barrel nanopipettes. The easy fabrication route allows deposition of semiconductors or conducting polymers to comprise the transistor channel. A channel from electrodeposited poly pyrrole (PPy) exhibits high sensitivity toward pH changes. This property is exploited by immobilizing hexokinase on PPy nano-FETs to give rise to a selective ATP biosensor. Extracellular pH and ATP gradients are key biochemical constituents in the microenvironment of living cells; we monitor their real-time changes in relation to cancer cells and cardiomyocytes. The highly localized detection is possible because of the high aspect ratio and the spear-like design of the nano-FET probes. The accurately positioned nano-FET sensors can detect concentration gradients in three-dimensional space, identify biochemical properties of a single living cell, and after cell membrane penetration perform intracellular measurements. PMID:26816294

  18. Principles of Metamorphic Petrology

    NASA Astrophysics Data System (ADS)

    Williams, Michael L.

    2009-05-01

    The field of metamorphic petrology has seen spectacular advances in the past decade, including new X-ray mapping techniques for characterizing metamorphic rocks and minerals, new internally consistent thermobarometers, new software for constructing and viewing phase diagrams, new methods to date metamorphic processes, and perhaps most significant, revised petrologic databases and the ability to calculate accurate phase diagrams and pseudosections. These tools and techniques provide new power and resolution for constraining pressure-temperature (P-T) histories and tectonic events. Two books have been fundamental for empowering petrologists and structural geologists during the past decade. Frank Spear's Metamorphic Phase Equilibria and Pressure-Temperature-Time Paths, published in 1993, builds on his seminal papers to provide a quantitative framework for P-T path analysis. Spear's book lays the foundation for modern quantitative metamorphic analysis. Cees Passchier and Rudolph Trouw's Microtectonics, published in 2005, with its superb photos and figures, provides the tools and the theory for interpreting deformation textures and inferring deformation processes.

  19. Teaching Tomorrow's Classics.

    ERIC Educational Resources Information Center

    Tighe, Mary Ann; Avinger, Charles

    1994-01-01

    Describes young adult novels that may prove to be classics of the genre. Discusses "The "Chocolate War" by Robert Cormier, "The Outsiders" by S. E. Hinton, "The Witch of Blackbird Pond" by Elizabeth George Speare, and "On Fortune's Wheel" by Cynthia Voight. (HB)

  20. An Update on Football Deaths and Catastrophic Injuries.

    ERIC Educational Resources Information Center

    Mueller, Frederick O.; Blyth, Carl S.

    1986-01-01

    The latest figures (1985) indicate a continued decline in football deaths and catastrophic injuries, which is credited to a ban on spearing and to a helmet standard. Guidelines for prevention of fatalities and injuries are listed. (Author/MT)

  1. Biobehavioral Insights into Adaptive Behavior in Complex and Dynamic Operational Settings: Lessons learned from the Soldier Performance and Effective, Adaptable Response Task

    PubMed Central

    Haufler, Amy J.; Lewis, Gregory F.; Davila, Maria I.; Westhelle, Felipe; Gavrilis, James; Bryce, Crystal I.; Kolacz, Jacek; Granger, Douglas A.; McDaniel, William

    2018-01-01

    The purpose of this study was to explore the biobehavioral correlates of adaptive behavior in the context of a standardized laboratory-based mission-relevant challenge [the Soldier Performance and Effective, Adaptable Response (SPEAR) task]. Participants were 26 healthy male volunteers (M = 34.85 years, SD = 4.12) with active military duty and leadership experience within the last 5 years (i.e., multiple leadership positions, operational deployments in combat, interactions with civilians and partner nation forces on the battlefield, experience making decisions under fire). The SPEAR task simultaneously engages perception, cognition, and action aspects of human performance demands similar to those encountered in the operational setting. Participants must engage with military-relevant text, visual, and auditory stimuli, interpret new information, and retain the commander’s intent in working memory to create a new plan of action for mission success. Time-domain measures of heart period and respiratory sinus arrhythmia (RSA) were quantified, and saliva was sampled [later assayed for cortisol and alpha-amylase (sAA)] before-, during-, and post-SPEAR. Results revealed a predictable pattern of withdraw and recovery of the cardiac vagal tone during repeated presentation of battlefield challenges. Recovery of vagal inhibition following executive function challenge was strongly linked to better task-related performance. Rate of RSA recovery was also associated with better recall of the commander’s intent. Decreasing magnitude in the skin conductance response prior to the task was positively associated with better overall task-related performance. Lower levels of RSA were observed in participants who reported higher rates of combat deployments, and reduced RSA flexibility was associated with higher rates of casualty exposure. Greater RSA flexibility during SPEAR was associated with greater self-reported resilience. There was no consistent pattern of task-related change in cortisol or sAA. We conclude that individual differences in psychophysiological reactivity and regulation in response to an ecologically valid, military-relevant task are associated with performance-related adaptive behavior in this standardized operational setting. The implications for modern day warfare, where advancing our understanding of the nature of individual differences in adaptive problem solving is critical to mission success, fitness for duty, and other occupational health-related outcomes, are discussed. PMID:29459893

  2. Biobehavioral Insights into Adaptive Behavior in Complex and Dynamic Operational Settings: Lessons learned from the Soldier Performance and Effective, Adaptable Response Task.

    PubMed

    Haufler, Amy J; Lewis, Gregory F; Davila, Maria I; Westhelle, Felipe; Gavrilis, James; Bryce, Crystal I; Kolacz, Jacek; Granger, Douglas A; McDaniel, William

    2017-01-01

    The purpose of this study was to explore the biobehavioral correlates of adaptive behavior in the context of a standardized laboratory-based mission-relevant challenge [the Soldier Performance and Effective, Adaptable Response (SPEAR) task]. Participants were 26 healthy male volunteers (M = 34.85 years, SD = 4.12) with active military duty and leadership experience within the last 5 years (i.e., multiple leadership positions, operational deployments in combat, interactions with civilians and partner nation forces on the battlefield, experience making decisions under fire). The SPEAR task simultaneously engages perception, cognition, and action aspects of human performance demands similar to those encountered in the operational setting. Participants must engage with military-relevant text, visual, and auditory stimuli, interpret new information, and retain the commander's intent in working memory to create a new plan of action for mission success. Time-domain measures of heart period and respiratory sinus arrhythmia (RSA) were quantified, and saliva was sampled [later assayed for cortisol and alpha-amylase (sAA)] before-, during-, and post-SPEAR. Results revealed a predictable pattern of withdraw and recovery of the cardiac vagal tone during repeated presentation of battlefield challenges. Recovery of vagal inhibition following executive function challenge was strongly linked to better task-related performance. Rate of RSA recovery was also associated with better recall of the commander's intent. Decreasing magnitude in the skin conductance response prior to the task was positively associated with better overall task-related performance. Lower levels of RSA were observed in participants who reported higher rates of combat deployments, and reduced RSA flexibility was associated with higher rates of casualty exposure. Greater RSA flexibility during SPEAR was associated with greater self-reported resilience. There was no consistent pattern of task-related change in cortisol or sAA. We conclude that individual differences in psychophysiological reactivity and regulation in response to an ecologically valid, military-relevant task are associated with performance-related adaptive behavior in this standardized operational setting. The implications for modern day warfare, where advancing our understanding of the nature of individual differences in adaptive problem solving is critical to mission success, fitness for duty, and other occupational health-related outcomes, are discussed.

  3. Earliest stone-tipped projectiles from the Ethiopian rift date to >279,000 years ago.

    PubMed

    Sahle, Yonatan; Hutchings, W Karl; Braun, David R; Sealy, Judith C; Morgan, Leah E; Negash, Agazi; Atnafu, Balemwal

    2013-01-01

    Projectile weapons (i.e. those delivered from a distance) enhanced prehistoric hunting efficiency by enabling higher impact delivery and hunting of a broader range of animals while reducing confrontations with dangerous prey species. Projectiles therefore provided a significant advantage over thrusting spears. Composite projectile technologies are considered indicative of complex behavior and pivotal to the successful spread of Homo sapiens. Direct evidence for such projectiles is thus far unknown from >80,000 years ago. Data from velocity-dependent microfracture features, diagnostic damage patterns, and artifact shape reported here indicate that pointed stone artifacts from Ethiopia were used as projectile weapons (in the form of hafted javelin tips) as early as >279,000 years ago. In combination with the existing archaeological, fossil and genetic evidence, these data isolate eastern Africa as a source of modern cultures and biology.

  4. Anti-social networking: crowdsourcing and the cyber defence of national critical infrastructures.

    PubMed

    Johnson, Chris W

    2014-01-01

    We identify four roles that social networking plays in the 'attribution problem', which obscures whether or not cyber-attacks were state-sponsored. First, social networks motivate individuals to participate in Distributed Denial of Service attacks by providing malware and identifying potential targets. Second, attackers use an individual's social network to focus attacks, through spear phishing. Recipients are more likely to open infected attachments when they come from a trusted source. Third, social networking infrastructures create disposable architectures to coordinate attacks through command and control servers. The ubiquitous nature of these architectures makes it difficult to determine who owns and operates the servers. Finally, governments recruit anti-social criminal networks to launch attacks on third-party infrastructures using botnets. The closing sections identify a roadmap to increase resilience against the 'dark side' of social networking.

  5. Aflatoxin Production in Peanut Varieties by aspergillus flavus Link and Aspergillus parasiticus Speare

    PubMed Central

    Nagarajan, V.; Bhat, Ramesh V.

    1973-01-01

    Levels of aflatoxin produced in peanuts differed with the genetic variety of plant and with the species and strain of invading fungus. Possibilities for identifying groundnut varieties partially resistant to aflatoxin production are discussed. PMID:4632857

  6. Effects of light sources and intensity on broilers grown to heavy weights: Hematophysiological and biochemical assessment.

    USDA-ARS?s Scientific Manuscript database

    Most governments around the world including the USA have passed measures to phase out incandescent light bulbs in favor of more energy-efficient lighting alternatives. Research is limited on blood physiological variables of broilers grown to heavy weights (> 3 kg) under these new light sources to en...

  7. EGR distribution and fluctuation probe based on CO.sub.2 measurements

    DOEpatents

    Parks, II, James E; Partridge, Jr., William P; Yoo, Ji Hyung

    2015-04-07

    A diagnostic system having a single-port EGR probe and a method for using the same. The system includes a light source, an EGR probe, a detector and a processor. The light source may provide a combined light beam composed of light from a mid-infrared signal source and a mid-infrared reference source. The signal source may be centered at 4.2 .mu.m and the reference source may be centered at 3.8 .mu.m. The EGR probe may be a single-port probe with internal optics and a sampling chamber with two flow cells arranged along the light path in series. The optics may include a lens for focusing the light beam and a mirror for reflecting the light beam received from a pitch optical cable to a catch optical cable. The signal and reference sources are modulated at different frequencies, thereby allowing them to be separated and the signal normalized by the processor.

  8. Comparison of Reef Fish Survey Data Gathered by Open and Closed Circuit SCUBA Divers Reveals Differences in Areas With Higher Fishing Pressure

    PubMed Central

    Stamoulis, Kostantinos A.; Boland, Raymond C.; Lino, Kevin C.; Hauk, Brian B.; Leonard, Jason C.; Asher, Jacob M.; Lopes, Keolohilani H.; Kosaki, Randall K.

    2016-01-01

    Visual survey by divers using open-circuit (OC) SCUBA is the most widely used approach to survey coral reef fishes. Therefore, it is important to quantify sources of bias in OC surveys, such as the possibility that avoidance of OC divers by fishes can lead to undercounting in areas where targeted species have come to associate divers with a risk of being speared. One potential way to reduce diver avoidance is to utilize closed circuit rebreathers (CCRs), which do not produce the noise and bubbles that are a major source of disturbance associated with OC diving. For this study, we conducted 66 paired OC and CCR fish surveys in the Main Hawaiian Islands at locations with relatively high, moderate, and light fishing pressure. We found no significant differences in biomass estimates between OC and CCR surveys when data were pooled across all sites, however there were differences at the most heavily fished location, Oahu. There, biomass estimates from OC divers were significantly lower for several targeted fish groups, including surgeonfishes, targeted wrasses, and snappers, as well as for all targeted fishes combined, with mean OC biomass between 32 and 68% of mean CCR biomass. There were no clear differences between OC and CCR biomass estimates for these groups at sites with moderate or low fishing pressure, or at any location for other targeted fish groups, including groupers, parrotfishes, and goatfishes. Bias associated with avoidance of OC divers at heavily fished locations could be substantially reduced, or at least calibrated for, by utilization of CCR. In addition to being affected by fishing pressure, the extent to which avoidance of OC divers is problematic for visual surveys varies greatly among taxa, and is likely to be highly influenced by the survey methodology and dimensions used. PMID:27936044

  9. Comparison of Reef Fish Survey Data Gathered by Open and Closed Circuit SCUBA Divers Reveals Differences in Areas With Higher Fishing Pressure.

    PubMed

    Gray, Andrew E; Williams, Ivor D; Stamoulis, Kostantinos A; Boland, Raymond C; Lino, Kevin C; Hauk, Brian B; Leonard, Jason C; Rooney, John J; Asher, Jacob M; Lopes, Keolohilani H; Kosaki, Randall K

    2016-01-01

    Visual survey by divers using open-circuit (OC) SCUBA is the most widely used approach to survey coral reef fishes. Therefore, it is important to quantify sources of bias in OC surveys, such as the possibility that avoidance of OC divers by fishes can lead to undercounting in areas where targeted species have come to associate divers with a risk of being speared. One potential way to reduce diver avoidance is to utilize closed circuit rebreathers (CCRs), which do not produce the noise and bubbles that are a major source of disturbance associated with OC diving. For this study, we conducted 66 paired OC and CCR fish surveys in the Main Hawaiian Islands at locations with relatively high, moderate, and light fishing pressure. We found no significant differences in biomass estimates between OC and CCR surveys when data were pooled across all sites, however there were differences at the most heavily fished location, Oahu. There, biomass estimates from OC divers were significantly lower for several targeted fish groups, including surgeonfishes, targeted wrasses, and snappers, as well as for all targeted fishes combined, with mean OC biomass between 32 and 68% of mean CCR biomass. There were no clear differences between OC and CCR biomass estimates for these groups at sites with moderate or low fishing pressure, or at any location for other targeted fish groups, including groupers, parrotfishes, and goatfishes. Bias associated with avoidance of OC divers at heavily fished locations could be substantially reduced, or at least calibrated for, by utilization of CCR. In addition to being affected by fishing pressure, the extent to which avoidance of OC divers is problematic for visual surveys varies greatly among taxa, and is likely to be highly influenced by the survey methodology and dimensions used.

  10. Textured fluorapatite bonded to calcium sulphate strengthen stomatopod raptorial appendages.

    PubMed

    Amini, Shahrouz; Masic, Admir; Bertinetti, Luca; Teguh, Jefri Sanusi; Herrin, Jason S; Zhu, Xi; Su, Haibin; Miserez, Ali

    2014-01-01

    Stomatopods are shallow-water crustaceans that employ powerful dactyl appendages to hunt their prey. Deployed at high velocities, these hammer-like clubs or spear-like devices are able to inflict substantial impact forces. Here we demonstrate that dactyl impact surfaces consist of a finely-tuned mineral gradient, with fluorapatite substituting amorphous apatite towards the outer surface. Raman spectroscopy measurements show that calcium sulphate, previously not reported in mechanically active biotools, is co-localized with fluorapatite. Ab initio computations suggest that fluorapatite/calcium sulphate interfaces provide binding stability and promote the disordered-to-ordered transition of fluorapatite. Nanomechanical measurements show that fluorapatite crystalline orientation correlates with an anisotropic stiffness response and indicate significant differences in the fracture tolerance between the two types of appendages. Our findings shed new light on the crystallochemical and microstructural strategies allowing these intriguing biotools to optimize impact forces, providing physicochemical information that could be translated towards the synthesis of impact-resistant functional materials and coatings.

  11. Textured fluorapatite bonded to calcium sulphate strengthen stomatopod raptorial appendages

    NASA Astrophysics Data System (ADS)

    Amini, Shahrouz; Masic, Admir; Bertinetti, Luca; Teguh, Jefri Sanusi; Herrin, Jason S.; Zhu, Xi; Su, Haibin; Miserez, Ali

    2014-01-01

    Stomatopods are shallow-water crustaceans that employ powerful dactyl appendages to hunt their prey. Deployed at high velocities, these hammer-like clubs or spear-like devices are able to inflict substantial impact forces. Here we demonstrate that dactyl impact surfaces consist of a finely-tuned mineral gradient, with fluorapatite substituting amorphous apatite towards the outer surface. Raman spectroscopy measurements show that calcium sulphate, previously not reported in mechanically active biotools, is co-localized with fluorapatite. Ab initio computations suggest that fluorapatite/calcium sulphate interfaces provide binding stability and promote the disordered-to-ordered transition of fluorapatite. Nanomechanical measurements show that fluorapatite crystalline orientation correlates with an anisotropic stiffness response and indicate significant differences in the fracture tolerance between the two types of appendages. Our findings shed new light on the crystallochemical and microstructural strategies allowing these intriguing biotools to optimize impact forces, providing physicochemical information that could be translated towards the synthesis of impact-resistant functional materials and coatings.

  12. Compact OPO-based RGB source

    NASA Astrophysics Data System (ADS)

    Lee, Dicky; Moulton, Peter F.

    2001-03-01

    In this paper we discuss our red, green, and blue (RGB) optical parametric oscillator (OPO) light source for projection display applications. Our source consists of a diode-pumped pump laser and a LBO-based OPO. Based on our Nd:YLF gain-module design, the pump laser is frequency doubled to serve as the pump source for the OPO. The unconverted pump power is recycled as the green light for projection. The singly resonant, non-critically phase- matched OPO has, to date, generated 13 W of 898-nm signal power and an estimated 9.3 W of intra-cavity idler power at 1256 nm. With approximately 76% of pump depletion, the power of the residual green light for projection is about 5.8 W. We have extra-cavity doubled the signal to produce approximately 3.5 W of 449-nm blue light and intra-cavity doubled the idler to produce approximately 6 W of 628-nm red light. The OPO-based RGB source generates about 4000 lumens of D65-balanced white light. The overall electrical power luminous efficiency (diodes only) is about 14.6 lumens/Watt.

  13. Validation of luminescent source reconstruction using spectrally resolved bioluminescence images

    NASA Astrophysics Data System (ADS)

    Virostko, John M.; Powers, Alvin C.; Jansen, E. D.

    2008-02-01

    This study examines the accuracy of the Living Image® Software 3D Analysis Package (Xenogen, Alameda, CA) in reconstruction of light source depth and intensity. Constant intensity light sources were placed in an optically homogeneous medium (chicken breast). Spectrally filtered images were taken at 560, 580, 600, 620, 640, and 660 nanometers. The Living Image® Software 3D Analysis Package was employed to reconstruct source depth and intensity using these spectrally filtered images. For sources shallower than the mean free path of light there was proportionally higher inaccuracy in reconstruction. For sources deeper than the mean free path, the average error in depth and intensity reconstruction was less than 4% and 12%, respectively. The ability to distinguish multiple sources decreased with increasing source depth and typically required a spatial separation of twice the depth. The constant intensity light sources were also implanted in mice to examine the effect of optical inhomogeneity. The reconstruction accuracy suffered in inhomogeneous tissue with accuracy influenced by the choice of optical properties used in reconstruction.

  14. Detection of Instrumental Drifts in the PEP II LER BPM System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wittmer, W.; Fisher, A.S.; Martin, D.J.

    2007-11-07

    During the last PEP-II run a major goal was to bring the Low-Energy Ring optics as close as possible to the design. A large number of BPMs exhibited sudden artificial jumps that interfered with this effort. The source of the majority of these jumps had been traced to the filter-isolator boxes (FIBs) near the BPM buttons. A systematic approach to find and repair the failing units had been developed and implemented. Despite this effort, the instrumental orbit jumps never completely disappeared. To trace the source of this behavior a test setup, using a spare Bergoz MX-BPM processor (kindly provided bymore » SPEAR III at SSRL), was connected in parallel to various PEP-II BPM processors. In the course of these measurements a slow instrumental orbit drift was found which was clearly not induced by a moving positron beam. Based on the size of the system and the limited time before PEP-II closes in Oct.2008, an accelerator improvement project was initiated to install BERGOZ BPM-MX processors close to all sextupoles.« less

  15. Comparison of Depth of Cure, Hardness and Heat Generation of LED and High Intensity QTH Light Sources.

    PubMed

    Mousavinasab, Sayed Mostafa; Meyers, Ian

    2011-07-01

    To compare curing performance of a second generation LED curing light with a high power tungsten quartz halogen (QTH). A hybrid composite resin (Filtek Z 250, 3M, USA) was used as test material and cured using a second generation LED light (Translux Power Blue™, Heraus Kulzer ,Germany) or a very high power QTH light unit (EMS, Switzerland). A two split aluminum mold was used to prepare ten samples with LED light source cured for forty seconds and ten samples prepared using high power QTH light unit, cured for four or six seconds recommended exposure time. Hardness, depth of cure (DOC) and thermal rise during exposure time by these light sources were measured. The data submitted to analysis of variance (ANOVA), Tukey's and student's t tests at 5% significance level. Significant differences were found in hardness, DOC of samples cured by above mentioned light sources and also in thermal rises during exposure time. The curing performance of the tested QTH was not as well as the LED light. TPB light source produced the maximum hardness (81.25, 73.29, 65.49,55.83 and 24.53 for 0 mm, 1 mm, 2 mm, 3 mm and 4 mm intervals) and DOC (2.64 mm) values with forty seconds irradiation time and the high power (QTH) the least hardness (73.27, 61.51 and 31.59 for 0 mm, 1 mm and 2 mm, respectively) and DOC (2 mm) values with four seconds irradiation time. Thermal rises during 4 s and 6 s curing time using high power QTH and tested LED were 1.88°C, 3°C and 1.87°C, respectively. The used high power LED light produced greater hardness and depth of cure during forty seconds exposure time compared to high power QTH light with four or six seconds curing time. Thermal rise during 6 s curing time with QTH was greater compared to thermal changes occurred during 40 s curing time with tested LED light source. There was no difference seen in thermal changes caused by LED light with 40 s and QTH light with 4 s exposure time.

  16. 32 CFR 234.1 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Number 2, the Pentagon heating and sewage treatment plants, and other related facilities are located... Washington County, Maryland, and other related facilities. The Pentagon Reservation shall include all..., by compressed gas, or by spring power; any bow and arrow, crossbow, blowgun, spear gun, hand-thrown...

  17. 32 CFR 234.1 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Number 2, the Pentagon heating and sewage treatment plants, and other related facilities are located... Washington County, Maryland, and other related facilities. The Pentagon Reservation shall include all..., by compressed gas, or by spring power; any bow and arrow, crossbow, blowgun, spear gun, hand-thrown...

  18. 32 CFR 234.1 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Number 2, the Pentagon heating and sewage treatment plants, and other related facilities are located... Washington County, Maryland, and other related facilities. The Pentagon Reservation shall include all..., by compressed gas, or by spring power; any bow and arrow, crossbow, blowgun, spear gun, hand-thrown...

  19. 32 CFR 234.1 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Number 2, the Pentagon heating and sewage treatment plants, and other related facilities are located... Washington County, Maryland, and other related facilities. The Pentagon Reservation shall include all..., by compressed gas, or by spring power; any bow and arrow, crossbow, blowgun, spear gun, hand-thrown...

  20. 32 CFR 234.1 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Number 2, the Pentagon heating and sewage treatment plants, and other related facilities are located... Washington County, Maryland, and other related facilities. The Pentagon Reservation shall include all..., by compressed gas, or by spring power; any bow and arrow, crossbow, blowgun, spear gun, hand-thrown...

  1. The Endockscope Using Next Generation Smartphones: "A Global Opportunity".

    PubMed

    Tse, Christina; Patel, Roshan M; Yoon, Renai; Okhunov, Zhamshid; Landman, Jaime; Clayman, Ralph V

    2018-06-02

    The Endockscope combines a smartphone, a battery powered flashlight and a fiberoptic cystoscope allowing for mobile videocystoscopy. We compared conventional videocystoscopy to the Endockscope paired with next generation smartphones in an ex-vivo porcine bladder model to evaluate its image quality. The Endockscope consists of a three-dimensional (3D) printed attachment that connects a smartphone to a flexible fiberoptic cystoscope plus a 1000 lumen light-emitting diode (LED) cordless light source. Video recordings of porcine cystoscopy with a fiberoptic flexible cystoscope (Storz) were captured for each mobile device (iPhone 6, iPhone 6S, iPhone 7, Samsung S8, and Google Pixel) and for the high-definition H3-Z versatile camera (HD) set-up with both the LED light source and the xenon light (XL) source. Eleven faculty urologists, blinded to the modality used, evaluated each video for image quality/resolution, brightness, color quality, sharpness, overall quality, and acceptability for diagnostic use. When comparing the Endockscope coupled to an Galaxy S8, iPhone 7, and iPhone 6S with the LED portable light source to the HD camera with XL, there were no statistically significant differences in any metric. 82% and 55% of evaluators considered the iPhone 7 + LED light source and iPhone 6S + LED light, respectively, appropriate for diagnostic purposes as compared to 100% who considered the HD camera with XL appropriate. The iPhone 6 and Google Pixel coupled with the LED source were both inferior to the HD camera with XL in all metrics. The Endockscope system with a LED light source when coupled with either an iPhone 7 or Samsung S8 (total cost: $750) is comparable to conventional videocystoscopy with a standard camera and XL light source (total cost: $45,000).

  2. Online optimization of storage ring nonlinear beam dynamics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Xiaobiao; Safranek, James

    2015-08-01

    We propose to optimize the nonlinear beam dynamics of existing and future storage rings with direct online optimization techniques. This approach may have crucial importance for the implementation of diffraction limited storage rings. In this paper considerations and algorithms for the online optimization approach are discussed. We have applied this approach to experimentally improve the dynamic aperture of the SPEAR3 storage ring with the robust conjugate direction search method and the particle swarm optimization method. The dynamic aperture was improved by more than 5 mm within a short period of time. Experimental setup and results are presented.

  3. Application of 3D printing to prototype and develop novel plant tissue culture systems.

    PubMed

    Shukla, Mukund R; Singh, Amritpal S; Piunno, Kevin; Saxena, Praveen K; Jones, A Maxwell P

    2017-01-01

    Due to the complex process of designing and manufacturing new plant tissue culture vessels through conventional means there have been limited efforts to innovate improved designs. Further, development and availability of low cost, energy efficient LEDs of various spectra has made it a promising light source for plant growth in controlled environments. However, direct replacement of conventional lighting sources with LEDs does not address problems with uniformity, spectral control, or the challenges in conducting statistically valid experiments to assess the effects of light. Prototyping using 3D printing and LED based light sources could help overcome these limitations and lead to improved culture systems. A modular culture vessel design in which the fluence rate and spectrum of light are independently controlled was designed, prototyped using 3D printing, and evaluated for plant growth. This design is compatible with semi-solid and liquid based culture systems. Observations on morphology, chlorophyll content, and chlorophyll fluorescence based stress parameters from in vitro plants cultured under different light spectra with similar overall fluence rate indicated different responses in Nicotiana tabacum and Artemisia annua plantlets. This experiment validates the utility of 3D printing to design and test functional vessels and demonstrated that optimal light spectra for in vitro plant growth is species-specific. 3D printing was successfully used to prototype novel culture vessels with independently controlled variable fluence rate/spectra LED lighting. This system addresses several limitations associated with current lighting systems, providing more uniform lighting and allowing proper replication/randomization for experimental plant biology while increasing energy efficiency. A complete procedure including the design and prototyping of a culture vessel using 3D printing, commercial scale injection molding of the prototype, and conducting a properly replicated experiment are discussed. This open source design has the scope for further improvement and adaptation and demonstrates the power of 3D printing to improve the design of culture systems.

  4. Long Wavelength Electromagnetic Light Bullets Generated by a 10.6 micron CO2 Ultrashort Pulsed Source

    DTIC Science & Technology

    2016-11-29

    AFRL-AFOSR-VA-TR-2016-0365 Long Wavelength Electromagnetic Light Bullets Generated by a 10.6 micron CO2 Ultrashort Pulsed Source Jerome Moloney...SUBTITLE "Long Wavelength Electromagnetic Light Bullets Generated by a 10.6 micron CO2 Ultrashort Pulsed Source 5a. CONTRACT NUMBER FA9550-15-1-0272 5b...afosr.reports.sgizmo.com/s3/> Subject: Final Report to Dr. Arje Nachman Contract/Grant Title: Long Wavelength Electromagnetic Light Bullets Generated by a 10.6

  5. 77 FR 1975 - Safety Advisory: Unauthorized Marking of Compressed Gas Cylinders

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-12

    ... Jackson Plaza, Ann Arbor, MI improperly requalified and marked high pressure compressed gas cylinders... DOT specification cylinders after its authority to requalifiy high pressure cylinders expired on... that Spears Fire & Safety continued to requalify and mark high pressure cylinders after their authority...

  6. Physico-chemical factors influencing spore germination in cyanobacterium Fischerella muscicola.

    PubMed

    Mishra, Biranchi N; Kaushik, Manish S; Abraham, Gerard; Singh, Pawan K

    2018-06-19

    Spore (akinete) formation in the heterocystous and branched filamentous cyanobacterium Fischerella muscicola involves a significant increase in cell size and formation of several endospores in each of the cells. In present study, the physico-chemical factors (pH, light sources, nutrient deficiency, nitrogen sources, carbon sources, and growth hormones) affecting the germination of spores of F. muscicola were examined. Increase in spore germination frequency was detected above pH 8 with maximum germination (46.04%) recorded at pH 9, whereas a significant decrease in germination was observed at pH 6 when compared to control (pH 7.6). Spore germination was not observed at pH 5. Among light sources germination frequency followed the following order, that is, red light (39.9%) > white light (33.8%) > yellow light (3.4%) > green light (1.3%) whereas germination did not take place in dark and blue light. Ammonium chloride (NH 4 Cl) supported maximum (99.5%) germination frequency followed by calcium nitrate (Ca(NO 3 ) 2 ), potassium nitrate (KNO 3 ), and minimum germination was observed in urea. Nutrient (phosphorus, calcium, and magnesium) deficiency significantly enhanced the germination frequency with maximum increase in magnesium (Mg) deficient condition. Further, supplementation of carbon sources (glucose, fructose, and sodium acetate) and growth hormones (IAA and GA) also enhanced the germination frequency in this cyanobacterium. Therefore, it may be concluded that, those factors supporting higher germination frequency could be considered for successful production and use of this cyanobacterium in biofertilizer and other algal production technologies. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. High voltage interactions of a sounding rocket with the ambient and system-generated environments

    NASA Technical Reports Server (NTRS)

    Kuharski, Robert A.; Jongeward, Gary A.; Wilcox, Katherine G.; Rankin, Thomas V.; Roche, James C.

    1990-01-01

    EPSAT (environment power system analysis tool) is used to examine the design of SPEAR III, which is scheduled to fly in early 1991. It will test high-voltage designs in both ambient and system-generated environments. Two of the key questions that the experiment hopes to address are whether or not the earth's magnetic field can cause the current that a high-voltage object draws from the plasma to be far less than the current that would be drawn in the absence of the magnetic field and under what neutral environmental conditions a discharge from the high-voltage object to the plasma will occur. The EPSAT program makes it possible to perform a variety of analyses on a preliminary or conceptual-level description of a system in a short period of time. The calculations presented on SPEAR III are all done for a conceptual-level description. The calculations indicate that the experiment will produce the conditions necessary to address these questions.

  8. Effects of laryngoscope handle light source on the light intensity from disposable laryngoscope blades.

    PubMed

    Milne, A D; Brousseau, P A; Brousseau, C A

    2014-12-01

    A bench-top study was performed to assess the effects of different laryngoscope handles on the light intensity delivered from disposable metal or plastic laryngoscope blades. The light intensity from both the handle light sources themselves and the combined handle and laryngoscope blade sets was measured using a custom-designed testing system and light meter. Five samples of each disposable blade type were tested and compared with a standard re-usable stainless steel blade using three different handle/light sources (Vital Signs LED, Heine 2.5 V Xenon and 3.5 V Xenon). The light intensity delivered by the disposable blades ranged from 790 to 3846 lux for the different handle types. Overall, the 3.5 V Heine handle delivered the highest light output (p < 0.007) in comparison with the other handles. For the disposable blades, the overall light output was significantly higher from the plastic than the metal blades (p < 0.001). © 2014 The Association of Anaesthetists of Great Britain and Ireland.

  9. Artificial light sources differ in effect on birch seedling growth

    Treesearch

    David A. Marquis

    1965-01-01

    The use of artificial lights to grow tree seedlings for research and even for commercial uses is becoming common. With this has come an increasing awareness that not all types of artificial lights produce the same results (2, 3, 5). The presence or absence of particular wavelengths in the light source may cause large differences in height growth and morphological...

  10. Earliest Stone-Tipped Projectiles from the Ethiopian Rift Date to >279,000 Years Ago

    PubMed Central

    Sahle, Yonatan; Hutchings, W. Karl; Braun, David R.; Sealy, Judith C.; Morgan, Leah E.; Negash, Agazi; Atnafu, Balemwal

    2013-01-01

    Projectile weapons (i.e. those delivered from a distance) enhanced prehistoric hunting efficiency by enabling higher impact delivery and hunting of a broader range of animals while reducing confrontations with dangerous prey species. Projectiles therefore provided a significant advantage over thrusting spears. Composite projectile technologies are considered indicative of complex behavior and pivotal to the successful spread of Homo sapiens. Direct evidence for such projectiles is thus far unknown from >80,000 years ago. Data from velocity-dependent microfracture features, diagnostic damage patterns, and artifact shape reported here indicate that pointed stone artifacts from Ethiopia were used as projectile weapons (in the form of hafted javelin tips) as early as >279,000 years ago. In combination with the existing archaeological, fossil and genetic evidence, these data isolate eastern Africa as a source of modern cultures and biology. PMID:24236011

  11. Design of Synchrotron Light Source in Taiwan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuo, C. C.; Chang, H. P.; Chou, P. J.

    2007-01-19

    An intermediate energy synchrotron light source has been proposed. The goal is to construct a high performance light source in complementary to the existing 1.5 GeV synchrotron ring in Taiwan to boost the research capabilities. A 3 GeV machine with 518.4 m and 24-cell DBA lattice structure is considered and other options are also investigated. We report the 24-cell design considerations and its performances.

  12. Sports related concussion and spinal injuries: the need for changing spearing rules at the National Capital Amateur Football Association (NCAFA).

    PubMed Central

    Pelletier, Jacques C

    2006-01-01

    Introduction Returning an athlete to play following a spinal or concussive injury remains a challenge for the health practitioner making the decision. Among the possible mechanisms responsible for such injuries in amateur football, the concept of “spearing” has attracted a great deal of attention in sport medicine. Objective The purpose of this paper is to present a review of the diagnosis and treatment of the potentially catastrophic neck and head injuries caused by spearing in Canadian amateur football and to suggest the role the chiropractic profession can have in their prevention. It proposes to follow the recommendations advocated by the National Capital Amateur Football Association (NCAFA) athletic trainers group, led by a chiropractor. Methods Information regarding the concepts and prevention of “spearing”, concussion and spinal injuries at the amateur football level in both the United States and Canada was obtained using the following computerized search methods: PubMed – MeSH (via the National Center for Biotechnology Information (NCBI); The Index to Chiropractic Literature (ICL); Google Scholar Beta. Recent (2005) information on sports related spinal injuries and concussion were obtained by attendance at the 2005 Sports Related Concussion and Spine Injury Conference. Foxborough, Massachusetts. From a total of 698 references, 63 were retained. Conclusion Literature search yields very little information regarding Canadian statistics for amateur football neck and head injuries. The author encourages such injury data collecting and proposes that original Canadian studies and statistical analyses be carried out, such as those from diverse sports groups in the United States and abroad.1, 2, 3 The NCAFA group of trainers recommends a changing of the rules for “spearing” within the league and advocates gathering of Canadian based sports injury statistics. It also recognizes the need for public presentations (of concussion/spinal injuries).5 This paper describes the different interpretations of spearing rules at American and Canadian football associations, both at the amateur and professional levels; it further shows that injury prevention in sports is an absolute necessity and that the chiropractic profession should play a role in its application. It is suggested that chiropractors, who often attend to athletes who sustained sport related neck and head injuries, ought to contribute in their prevention and treatment. PMID:17549157

  13. An LED light source and novel fluorophore combinations improve fluorescence laparoscopic detection of metastatic pancreatic cancer in orthotopic mouse models.

    PubMed

    Metildi, Cristina A; Kaushal, Sharmeela; Lee, Claudia; Hardamon, Chanae R; Snyder, Cynthia S; Luiken, George A; Talamini, Mark A; Hoffman, Robert M; Bouvet, Michael

    2012-06-01

    The aim of this study was to improve fluorescence laparoscopy of pancreatic cancer in an orthotopic mouse model with the use of a light-emitting diode (LED) light source and optimal fluorophore combinations. Human pancreatic cancer models were established with fluorescent FG-RFP, MiaPaca2-GFP, BxPC-3-RFP, and BxPC-3 cancer cells implanted in 6-week-old female athymic mice. Two weeks postimplantation, diagnostic laparoscopy was performed with a Stryker L9000 LED light source or a Stryker X8000 xenon light source 24 hours after tail-vein injection of CEA antibodies conjugated with Alexa 488 or Alexa 555. Cancer lesions were detected and localized under each light mode. Intravital images were also obtained with the OV-100 Olympus and Maestro CRI Small Animal Imaging Systems, serving as a positive control. Tumors were collected for histologic analysis. Fluorescence laparoscopy with a 495-nm emission filter and an LED light source enabled real-time visualization of the fluorescence-labeled tumor deposits in the peritoneal cavity. The simultaneous use of different fluorophores (Alexa 488 and Alexa 555), conjugated to antibodies, brightened the fluorescence signal, enhancing detection of submillimeter lesions without compromising background illumination. Adjustments to the LED light source permitted simultaneous detection of tumor lesions of different fluorescent colors and surrounding structures with minimal autofluorescence. Using an LED light source with adjustments to the red, blue, and green wavelengths, it is possible to simultaneously identify tumor metastases expressing fluorescent proteins of different wavelengths, which greatly enhanced the signal without compromising background illumination. Development of this fluorescence laparoscopy technology for clinical use can improve staging and resection of pancreatic cancer. Copyright © 2012 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  14. The study of LED light source illumination conditions for ideal algae cultivation

    NASA Astrophysics Data System (ADS)

    Tsai, Chun-Chin; Huang, Chien-Fu; Chen, Cin-Fu; Yue, Cheng-Feng

    2017-02-01

    Utilizing LED light source modules with 3 different RGB colors, the illumination effect of different wavelengths had been investigated on the growth curve of the same kind of micro algae. It was found that the best micro algae culturing status came out with long wavelength light such as red light (650 670 nm). Based on the same condition for a period of 3 weeks , the grown micro algae population density ratio represented by Optical Density (O.D.) ratio is 1?0.4?0.7 corresponding to growth with Red, Green, Blue light sources, respectively. Mixing 3 types and 2 types of LEDs with different parameters, the grown micro algae population densities were compared in terms of O.D. Interestingly enough, different light sources resulted in significant discoloration on micro algae growth, appearing yellow, brown, green, etc. Our experiments results showed such discoloration effect is reversible. Based on the same lighting condition, micro algae growth can be also affected by incubator size, nutrition supply, and temperature variation. In recent years, micro algae related technologies have been international wise a hot topic of energy and environmental protection for research and development institutes, and big energy companies among those developed countries. There will be an economically prosperous future. From this study of LED lighting to ideal algae cultivation, it was found that such built system would be capable of optimizing artificial cultivation system, leading to economic benefits for its continuous development. Since global warming causing weather change, accompanying with reducing energy sources and agriculture growth shortage are all threatening human being survival.

  15. Fundamental characteristics of a synthesized light source for optical coherence tomography.

    PubMed

    Sato, Manabu; Wakaki, Ichiro; Watanabe, Yuuki; Tanno, Naohiro

    2005-05-01

    We describe the fundamental characteristics of a synthesized light source (SLS) consisting of two low-coherence light sources to enhance the spatial resolution for optical coherence tomography (OCT). The axial resolution of OCT is given by half the coherence length of the light source. We fabricated a SLS with a coherence length of 2.3 microm and a side-lobe intensity of 45% with an intensity ratio of LED1:LED2 = 1:0.5 by combining two light sources, LED1, with a central wavelength of 691 nm and a spectral bandwidth of 99 nm, and LED2, with a central wavelength of 882 nm and a spectral bandwidth of 76 nm. The coherence length of 2.3 microm was 56% of the shorter coherence length in the two LEDs, which indicates that the axial resolution is 1.2 microm. The lateral resolution was measured at less than 4.4 microm by use of the phase-shift method and with a test pattern as a sample. The measured rough surfaces of a coin are illustrated and discussed.

  16. The future of transportation planning : dynamic travel behavior analyses based on stochastic decision-making styles : final report.

    DOT National Transportation Integrated Search

    2003-08-01

    Over the past half-century, the progress of travel behavior research and travel demand forecasting has been spear : headed and continuously propelled by the micro-economic theories, specifically utility maximization. There is no : denial that the tra...

  17. 15 CFR 922.164 - Additional activity regulations by Sanctuary area.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., breaking, cutting, spearing or similarly injuring any coral or other marine invertebrate, or any plant... injuring any coral, marine invertebrate, fish, bottom formation, algae, seagrass or other living or dead organism, including shells, or attempting any of these activities. However, fish, invertebrates, and marine...

  18. Catching Butterflies

    ERIC Educational Resources Information Center

    Fisher, Maisha T.

    2008-01-01

    Playmaking for Girls, founded by Rachel May and directed by Susie Spear Purcell, assembles a diverse ensemble of teaching artists committed to using playwriting and performance to help with incarcerated and formerly incarcerated teen girls to help them "think and thus act for themselves" (Freden, 2001, p. 70). These teaching artists, with the…

  19. Understanding "Romeo and Juliet": A Thematic Unit.

    ERIC Educational Resources Information Center

    Koveleski, Erin

    This curriculum unit for Grade 9 combines the classic Shakespeare play "Romeo and Juliet" with three young adult novels: "The Outsiders" (S.E. Hinton), "Summer of My German Soldier" (Bette Greene), and "The Witch of Blackbird Pond" (Elizabeth George Speare). To complete the unit, all students will be…

  20. Spear Fishing in Wisconsin: Multicultural Education as Symbolic Violence.

    ERIC Educational Resources Information Center

    New, William; Petronicolos, Loucas

    2001-01-01

    Describes how multicultural teacher education can preserve familiar institutional and ideological mechanisms that validate social inequalities, analyzing student discourse collected during activities concerning recent conflict between Native American groups and groups opposed to the exercise of their treaty rights to fish on nonreservation lakes.…

  1. Setting Priorities in Behavioral Interventions: An Application to Reducing Phishing Risk.

    PubMed

    Canfield, Casey Inez; Fischhoff, Baruch

    2018-04-01

    Phishing risk is a growing area of concern for corporations, governments, and individuals. Given the evidence that users vary widely in their vulnerability to phishing attacks, we demonstrate an approach for assessing the benefits and costs of interventions that target the most vulnerable users. Our approach uses Monte Carlo simulation to (1) identify which users were most vulnerable, in signal detection theory terms; (2) assess the proportion of system-level risk attributable to the most vulnerable users; (3) estimate the monetary benefit and cost of behavioral interventions targeting different vulnerability levels; and (4) evaluate the sensitivity of these results to whether the attacks involve random or spear phishing. Using parameter estimates from previous research, we find that the most vulnerable users were less cautious and less able to distinguish between phishing and legitimate emails (positive response bias and low sensitivity, in signal detection theory terms). They also accounted for a large share of phishing risk for both random and spear phishing attacks. Under these conditions, our analysis estimates much greater net benefit for behavioral interventions that target these vulnerable users. Within the range of the model's assumptions, there was generally net benefit even for the least vulnerable users. However, the differences in the return on investment for interventions with users with different degrees of vulnerability indicate the importance of measuring that performance, and letting it guide interventions. This study suggests that interventions to reduce response bias, rather than to increase sensitivity, have greater net benefit. © 2017 Society for Risk Analysis.

  2. A cluster randomized controlled trial to increase the availability and acceptability of voluntary medical male circumcision in Zambia: The Spear and Shield Project

    PubMed Central

    Weiss, Stephen M; Zulu, Robert; Jones, Deborah L; Redding, Colleen A; Cook, Ryan; Chitalu, Ndashi

    2015-01-01

    Background Widespread voluntary medical male circumcision (VMMC) in Africa could avert an estimated 3·436 million HIV infections and 300,000 deaths over the next 10 years. Most Zambian men, however, have expressed little interest in undergoing VMMC. This study tested the effect of an intervention designed to increase demand for VMMC among these “hard to reach” men. Methods This cluster randomized controlled trial was conducted from 2012 to 2014 in Lusaka, Zambia (HIV prevalence = 20·8%). 13 Community Health Centers (CHCs) were stratified by HIV voluntary counseling and testing (VCT) rates and patient census and randomly assigned (5:5:3) to Experimental, Control or Observation Only conditions. CHC health care providers at all 13 sites received VMMC training. Trial statisticians did not participate in randomization. 800 uncircumcised HIV-, post-VCT men, 400 per condition, were recruited; female partners were invited to participate. The primary outcome was the likelihood of VMMC by 12 months post-intervention. The trial registration is NCT 01688167. Findings 161 participants in the Experimental condition underwent VMMC as compared to 96 Control participants [adjusted odds ratio = 2·45, 95% CI = (1·24, 4·90) p = ·0166]. Post-VMMC condom use among Experimental condition participants increased compared to baseline, with no change among Control participants. No adverse events related to study participation were reported. Interpretation The Spear and Shield intervention combined with VMMC training was associated with a significant increase in the number of VMMCs performed as well as in condom use among “hard to reach” Zambian men. Results support the importance of comprehensive HIV prevention programs that increase supply of and demand for VMMC services. Funding NIH/NIMH R01MH095539. PMID:26120594

  3. LED and Halogen Light Transmission through a CAD/CAM Lithium Disilicate Glass-Ceramic.

    PubMed

    Pereira, Carolina Nemesio de Barros; De Magalhães, Cláudia Silami; Daleprane, Bruno; Peixoto, Rogéli Tibúrcio Ribeiro da Cunha; Ferreira, Raquel da Conceição; Cury, Luiz Alberto; Moreira, Allyson Nogueira

    2015-01-01

    The effect of thickness, shade and translucency of CAD/CAM lithium disilicate glass-ceramic on light transmission of light-emitting diode (LED) and quartz-tungsten-halogen units (QTH) were evaluated. Ceramic IPS e.max CAD shades A1, A2, A3, A3.5, high (HT) and low (LT) translucency were cut (1, 2, 3, 4 and 5 mm). Light sources emission spectra were determined. Light intensity incident and transmitted through each ceramic sample was measured to determine light transmission percentage (TP). Statistical analysis used a linear regression model. There was significant interaction between light source and ceramic translucency (p=0.008) and strong negative correlation (R=-0.845, p<0.001) between ceramic thickness and TP. Increasing one unit in thickness led to 3.17 reduction in TP. There was no significant difference in TP (p=0.124) between shades A1 (ß1=0) and A2 (ß1=-0.45) but significant reduction occurred for A3 (ß1=-0.83) and A3.5 (ß1=-2.18). The interaction QTH/HT provided higher TP (ß1=0) than LED/HT (ß1=-2.92), QTH/LT (ß1=-3.75) and LED/LT (ß1=-5.58). Light transmission was more effective using halogen source and high-translucency ceramics, decreased as the ceramic thickness increased and was higher for the lighter shades, A1 and A2. From the regression model (R2=0.85), an equation was obtained to estimate TP value using each variable ß1 found. A maximum TP of 25% for QTH and 20% for LED was found, suggesting that ceramic light attenuation could compromise light cured and dual cure resin cements polymerization.

  4. Pulp Chamber Heating: An In Vitro Study Evaluating Different Light Sources and Resin Composite Layers.

    PubMed

    Andreatta, Lígia Maria Lima; Furuse, Adilson Yoshio; Prakki, Anuradha; Bombonatti, Juliana Fraga Soares; Mondelli, Rafael Francisco Lia

    2016-01-01

    The aim of the present in vitro study was to evaluate the temperature variation inside the pulp chamber during light-activation of the adhesive and resin composite layers with different light sources. Cavities measuring 8x10 mm were prepared on the buccal surface of bovine incisors, leaving a remaining dentin thickness of 1 mm. Specimens were placed in a 37±1 °C water bath to standardize the temperature. The temperature in the pulp chamber was measured every 10 s during 40 s of light activation of the adhesive system (SBMP-3M/ESPE) and in the three consecutive 1-mm-thick layers of resin composite (Z250-3M/ESPE). Three light source devices were evaluated: Elipar 2500 (QTH), LD Max (LED low irradiance) and VALO (LED high irradiance). The results were submitted to one-way ANOVA with repeated measures and Tukey's test, both with p<0.001. The exothermic reaction warming was observed in the Z250 increments, but not in the SBMP. The high irradiance LED showed a higher temperature average (42.7±1.56 °C), followed by the quartz-tungsten-halogen light (40.6±0.67 °C) and the lower irradiance LED (37.8±0.12 °C). Higher temperature increases were observed with the adhesive and the first resin composite increment light-activation, regardless of the employed light source. From the second increment of Z250, the restorative material acted as a dispersive structure of heat, reducing temperature increases. Regardless the light source and restorative step, the temperature increased with the irradiation time. It may be concluded that the light source, irradiation time and resin composite thickness interfered in the temperature variation inside the pulp chamber.

  5. Novel fusion for hybrid optical/microcomputed tomography imaging based on natural light surface reconstruction and iterated closest point

    NASA Astrophysics Data System (ADS)

    Ning, Nannan; Tian, Jie; Liu, Xia; Deng, Kexin; Wu, Ping; Wang, Bo; Wang, Kun; Ma, Xibo

    2014-02-01

    In mathematics, optical molecular imaging including bioluminescence tomography (BLT), fluorescence tomography (FMT) and Cerenkov luminescence tomography (CLT) are concerned with a similar inverse source problem. They all involve the reconstruction of the 3D location of a single/multiple internal luminescent/fluorescent sources based on 3D surface flux distribution. To achieve that, an accurate fusion between 2D luminescent/fluorescent images and 3D structural images that may be acquired form micro-CT, MRI or beam scanning is extremely critical. However, the absence of a universal method that can effectively convert 2D optical information into 3D makes the accurate fusion challengeable. In this study, to improve the fusion accuracy, a new fusion method for dual-modality tomography (luminescence/fluorescence and micro-CT) based on natural light surface reconstruction (NLSR) and iterated closest point (ICP) was presented. It consisted of Octree structure, exact visual hull from marching cubes and ICP. Different from conventional limited projection methods, it is 360° free-space registration, and utilizes more luminescence/fluorescence distribution information from unlimited multi-orientation 2D optical images. A mouse mimicking phantom (one XPM-2 Phantom Light Source, XENOGEN Corporation) and an in-vivo BALB/C mouse with implanted one luminescent light source were used to evaluate the performance of the new fusion method. Compared with conventional fusion methods, the average error of preset markers was improved by 0.3 and 0.2 pixels from the new method, respectively. After running the same 3D internal light source reconstruction algorithm of the BALB/C mouse, the distance error between the actual and reconstructed internal source was decreased by 0.19 mm.

  6. SPIM-fluid: open source light-sheet based platform for high-throughput imaging

    PubMed Central

    Gualda, Emilio J.; Pereira, Hugo; Vale, Tiago; Estrada, Marta Falcão; Brito, Catarina; Moreno, Nuno

    2015-01-01

    Light sheet fluorescence microscopy has recently emerged as the technique of choice for obtaining high quality 3D images of whole organisms/embryos with low photodamage and fast acquisition rates. Here we present an open source unified implementation based on Arduino and Micromanager, which is capable of operating Light Sheet Microscopes for automatized 3D high-throughput imaging on three-dimensional cell cultures and model organisms like zebrafish, oriented to massive drug screening. PMID:26601007

  7. 15 CFR 922.164 - Additional activity regulations by Sanctuary area.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., breaking, cutting, spearing or similarly injuring any coral or other marine invertebrate, or any plant... injuring any coral, marine invertebrate, fish, bottom formation, algae, seagrass or other living or dead...) Except for catch and release fishing by trolling in the Conch Reef, Alligator Reef, Sombrero Reef, and...

  8. 75 FR 13485 - Proposed Information Collection; Comment Request; Socioeconomic Research and Monitoring for the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-22

    ... potential displacement of activity from the research only area alternative. For business operations, costs... Collection; Comment Request; Socioeconomic Research and Monitoring for the Gray's Reef National Marine... regulations: (1) Prohibition of spear fishing and (2) research only area. Information was obtained to assess...

  9. Attribution of Spear Phishing Attacks: A Literature Survey

    DTIC Science & Technology

    2013-08-01

    header of an email, verbally informed by another person, or easily ascertained via the handwriting of the text. In a few specific cases, this...scene would be scrutinised, based on both the handwriting and the content of the letter, to identify a suspect. The goal of this phase is to establish

  10. Modeling of Lamb Waves and Application to Crack Identification

    DTIC Science & Technology

    2009-09-01

    and Structures, vol. 13, pp. 621–630, 2004. [13] Seth S Kessler , S. Mark Spearing, and Constantinos Soutis, “Damage detection in composite materials...growth in metallic structures. Kessler et al. [13] presented part of an experimental and analytical survey of candidate methods for in-situ damage

  11. 50 CFR 600.725 - General prohibitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... reel, handline, spear. 6. American Lobster Fishery (FMP): A. Lobster pot and trap fishery A. Pot, trap... Fishery (Non-FMP) Trawl. 9. American Lobster Fishery (FMP managed by NEFMC): A. Pot and trap fishery A.... 7. South Atlantic Spiny Lobster Fishery (FMP): A. Commercial fishery A. Trap, pot, dip net, bully...

  12. 50 CFR 600.725 - General prohibitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... reel, handline, spear. 6. American Lobster Fishery (FMP): A. Lobster pot and trap fishery A. Pot, trap... Fishery (Non-FMP) Trawl. 9. American Lobster Fishery (FMP managed by NEFMC): A. Pot and trap fishery A.... 7. South Atlantic Spiny Lobster Fishery (FMP): A. Commercial fishery A. Trap, pot, dip net, bully...

  13. Similarities of Recently Acquired and Reactivated Memories in Interference

    ERIC Educational Resources Information Center

    Gordon, William C.

    1977-01-01

    Together, these studies replicate and extend Gordon and Spear's (1973a) findings that proactive interference decreases as the interval between prior and subsequent learning increases and that reactivation of a prior memory just before subsequent learning significantly increases the proactive interference due to the prior learning. (Author/RK)

  14. 21 CFR 886.4790 - Ophthalmic sponge.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic sponge. 886.4790 Section 886.4790 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4790 Ophthalmic sponge. (a) Identification. An ophthalmic sponge is a device that is an absorbant sponge, pad, or spear made of folded gauze, cotton...

  15. Characterizing small RNA populations in non-transgenic and aflatoxin-reducing-transgenic peanut lines

    USDA-ARS?s Scientific Manuscript database

    Aflatoxin contamination is a major constraint in the food production worlwide. In peanut these aflatoxins are mainly produced by Aspergillus flavus (Link) and A. parasiticus (Speare). The use of RNA interference (RNAi) is a promising method to reduce or prevent the accumulation of aflatoxin in pean...

  16. Re-Conceptualizing the Organizing Circumstance of Learning

    ERIC Educational Resources Information Center

    Spear Ellinwood, Karen Courtenay

    2011-01-01

    This study explores the web-navigation practices of adult learners in higher education and re-conceptualizes the concept of the organizing circumstance of self-managed learning, originated by Spear and Mocker (1984). The theoretical framework draws on funds of knowledge theory from a cultural historical perspective and elaborates a Vygotskian…

  17. Blunting the Spear: Why Good People Get Out

    DTIC Science & Technology

    2013-06-01

    enterprise to fill MCE, LRE, FTU, and additional billets. 17 Hardison, Mattock, Lytell, Incentive Pay for RPA, xiv. 18 Lolita C. Baldor, “Next Top...Air Force Website, 17 January 2013. 169 (Accessed 22 January 2013). Baldor, Lolita C. “Next Top Guns? Air Force faces Shortage of Drone Pilots

  18. Low-frequency wide-field fluorescence lifetime imaging using a high-power near-infrared light-emitting diode light source

    PubMed Central

    Gioux, Sylvain; Lomnes, Stephen J.; Choi, Hak Soo; Frangioni, John V.

    2010-01-01

    Fluorescence lifetime imaging (FLi) could potentially improve exogenous near-infrared (NIR) fluorescence imaging, because it offers the capability of discriminating a signal of interest from background, provides real-time monitoring of a chemical environment, and permits the use of several different fluorescent dyes having the same emission wavelength. We present a high-power, LED-based, NIR light source for the clinical translation of wide-field (larger than 5 cm in diameter) FLi at frequencies up to 35 MHz. Lifetime imaging of indocyanine green (ICG), IRDye 800-CW, and 3,3′-diethylthiatricarbocyanine iodide (DTTCI) was performed over a large field of view (10 cm by 7.5 cm) using the LED light source. For comparison, a laser diode light source was employed as a gold standard. Experiments were performed both on the bench by diluting the fluorescent dyes in various chemical environments in Eppendorf tubes, and in vivo by injecting the fluorescent dyes mixed in Matrigel subcutaneously into CD-1 mice. Last, measured fluorescence lifetimes obtained using the LED and the laser diode sources were compared with those obtained using a state-of-the-art time-domain imaging system and with those previously described in the literature. On average, lifetime values obtained using the LED and the laser diode light sources were consistent, exhibiting a mean difference of 3% from the expected values and a coefficient of variation of 12%. Taken together, our study offers an alternative to laser diodes for clinical translation of FLi and explores the use of relatively low frequency modulation for in vivo imaging. PMID:20459250

  19. Development of a microsecond X-ray protein footprinting facility at the Advanced Light Source.

    PubMed

    Gupta, Sayan; Celestre, Richard; Petzold, Christopher J; Chance, Mark R; Ralston, Corie

    2014-07-01

    X-ray footprinting (XF) is an important structural biology tool used to determine macromolecular conformations and dynamics of both nucleic acids and proteins in solution on a wide range of timescales. With the impending shut-down of the National Synchrotron Light Source, it is ever more important that this tool continues to be developed at other synchrotron facilities to accommodate XF users. Toward this end, a collaborative XF program has been initiated at the Advanced Light Source using the white-light bending-magnet beamlines 5.3.1 and 3.2.1. Accessibility of the microsecond time regime for protein footprinting is demonstrated at beamline 5.3.1 using the high flux density provided by a focusing mirror in combination with a micro-capillary flow cell. It is further reported that, by saturating samples with nitrous oxide, the radiolytic labeling efficiency is increased and the imprints of bound versus bulk water can be distinguished. These results both demonstrate the suitability of the Advanced Light Source as a second home for the XF experiment, and pave the way for obtaining high-quality structural data on complex protein samples and dynamics information on the microsecond timescale.

  20. 46 CFR 112.25-3 - Normal source for emergency loads.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....25-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas Turbine Driven Emergency Power Source as the Sole Emergency Power Source § 112.25-3 Normal source for...

  1. 46 CFR 112.30-3 - Normal source for emergency loads.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....30-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-3 Normal source for emergency loads. (a) The normal source...

  2. 46 CFR 112.25-3 - Normal source for emergency loads.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....25-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas Turbine Driven Emergency Power Source as the Sole Emergency Power Source § 112.25-3 Normal source for...

  3. 46 CFR 112.30-3 - Normal source for emergency loads.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ....30-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-3 Normal source for emergency loads. (a) The normal source...

  4. 46 CFR 112.30-3 - Normal source for emergency loads.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....30-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-3 Normal source for emergency loads. (a) The normal source...

  5. 46 CFR 112.30-3 - Normal source for emergency loads.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....30-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-3 Normal source for emergency loads. (a) The normal source...

  6. 46 CFR 112.25-3 - Normal source for emergency loads.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ....25-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas Turbine Driven Emergency Power Source as the Sole Emergency Power Source § 112.25-3 Normal source for...

  7. 46 CFR 112.30-3 - Normal source for emergency loads.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....30-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatically Connected Storage Battery as the Sole Emergency Power Source § 112.30-3 Normal source for emergency loads. (a) The normal source...

  8. 46 CFR 112.25-3 - Normal source for emergency loads.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....25-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas Turbine Driven Emergency Power Source as the Sole Emergency Power Source § 112.25-3 Normal source for...

  9. 46 CFR 112.25-3 - Normal source for emergency loads.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....25-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having an Automatic Starting Diesel Engine or Gas Turbine Driven Emergency Power Source as the Sole Emergency Power Source § 112.25-3 Normal source for...

  10. Photostimulation of osteogenic differentiation on silk scaffolds by plasma arc light source.

    PubMed

    Çakmak, Anıl Sera; Çakmak, Soner; Vatansever, H Seda; Gümüşderelioğlu, Menemşe

    2018-05-01

    Low-level laser therapy (LLLT) has been used for more than 30 years to heal wounds. In recent years, LLLT or photostimulation has been indicated as an effective tool for regenerative and dental medicine by using monochromatic light. The aim of this study is to indicate the usability of plasma arc light source for bone regeneration. This is why we used polychromatic light source providing effective wavelengths in the range of 590-1500 nm for cellular response and investigated photostimulation effects on osteogenic differentiation of human mesenchymal stem cells (hMSCs) seeded on 3D silk scaffolds. Cellular responses were examined by using cell culture methods in terms of proliferation, differentiation, and morphological analyses. The results showed that photostimulation with a polychromatic light source (applied for 5 min from the 3rd day after seeding up to the 28th day in 2-day intervals with 92-mW/cm 2 power from 10-cm distance to the cells) enhanced osteogenic differentiation of hMSCs according to higher alkaline phosphatase (ALP) activity, collagen and calcium content, osteogenic gene expressions, and matrix mineralization. In conclusion, we suggest that the plasma arc light source that was used here has a great potential for bone regeneration.

  11. Optimization of light source parameters in the photodynamic therapy of heterogeneous prostate

    NASA Astrophysics Data System (ADS)

    Li, Jun; Altschuler, Martin D.; Hahn, Stephen M.; Zhu, Timothy C.

    2008-08-01

    The three-dimensional (3D) heterogeneous distributions of optical properties in a patient prostate can now be measured in vivo. Such data can be used to obtain a more accurate light-fluence kernel. (For specified sources and points, the kernel gives the fluence delivered to a point by a source of unit strength.) In turn, the kernel can be used to solve the inverse problem that determines the source strengths needed to deliver a prescribed photodynamic therapy (PDT) dose (or light-fluence) distribution within the prostate (assuming uniform drug concentration). We have developed and tested computational procedures to use the new heterogeneous data to optimize delivered light-fluence. New problems arise, however, in quickly obtaining an accurate kernel following the insertion of interstitial light sources and data acquisition. (1) The light-fluence kernel must be calculated in 3D and separately for each light source, which increases kernel size. (2) An accurate kernel for light scattering in a heterogeneous medium requires ray tracing and volume partitioning, thus significant calculation time. To address these problems, two different kernels were examined and compared for speed of creation and accuracy of dose. Kernels derived more quickly involve simpler algorithms. Our goal is to achieve optimal dose planning with patient-specific heterogeneous optical data applied through accurate kernels, all within clinical times. The optimization process is restricted to accepting the given (interstitially inserted) sources, and determining the best source strengths with which to obtain a prescribed dose. The Cimmino feasibility algorithm is used for this purpose. The dose distribution and source weights obtained for each kernel are analyzed. In clinical use, optimization will also be performed prior to source insertion to obtain initial source positions, source lengths and source weights, but with the assumption of homogeneous optical properties. For this reason, we compare the results from heterogeneous optical data with those obtained from average homogeneous optical properties. The optimized treatment plans are also compared with the reference clinical plan, defined as the plan with sources of equal strength, distributed regularly in space, which delivers a mean value of prescribed fluence at detector locations within the treatment region. The study suggests that comprehensive optimization of source parameters (i.e. strengths, lengths and locations) is feasible, thus allowing acceptable dose coverage in a heterogeneous prostate PDT within the time constraints of the PDT procedure.

  12. Large area full-field optical coherence tomography using white light source

    NASA Astrophysics Data System (ADS)

    Chang, Shoude; Mao, Youxin; Sherif, Sherif; Flueraru, Costel

    2007-06-01

    Optical coherence tomography (OCT) is an emerging technology for high-resolution cross-sectional imaging of 3D structures. Not only could OCT extract the internal features of an object, but it could acquire the 3D profile of an object as well. Hence it has huge potentials for industrial applications. Owing to non-scanning along the X-Y axis, full-field OCT could be the simplest and most economic imaging system, especially for applications where the speed is critical. For an OCT system, the performance and cost basically depends on the light source being used. The broader the source bandwidth, the finer of the depth resolution that could be reached; the more power of the source, the better signal-to-noise ratio and the deeper of penetration the system achieves. A typical SLD (Superluminescent Diode) light source has a bandwidth of 15 nm and 10 mW optical power at a price around 6,000. However, a Halogen bulb having 50W power and 200nm bandwidth only costs less than 10. The design and implementation of a large-area, full-field OCT system using Halogen white-light source is described in the paper. The experimental results obtained from 3D shaping and multiple-layer tomographies are also presented.

  13. Broadband near-field infrared spectroscopy with a high temperature plasma light source.

    PubMed

    Lahneman, D J; Huffman, T J; Xu, Peng; Wang, S L; Grogan, T; Qazilbash, M M

    2017-08-21

    Scattering-type scanning near-field optical microscopy (S-SNOM) has enormous potential as a spectroscopy tool in the infrared spectral range where it can probe phonon resonances and carrier dynamics at the nanometer lengths scales. However, its applicability is limited by the lack of practical and affordable table-top light sources emitting intense broadband infrared radiation in the 100 cm -1 to 2,500 cm -1 spectral range. This paper introduces a high temperature plasma light source that is both ultra-broadband and has much more radiant power in the infrared spectral range than conventional, table-top thermal light sources such as the globar. We implement this plasma lamp in our near-field optical spectroscopy set up and demonstrate its capability as a broadband infrared nano-spectroscopy light source by obtaining near-field infrared amplitude and phase spectra of the phonon resonances of SiO 2 and SrTiO 3 .

  14. Atomic physics research with second and third generation synchrotron light sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, B.M.

    1990-10-01

    This contribution to these proceedings is intended to provide an introduction and overview for other contributions on atomic (and related) physics research at existing and planned synchrotron light sources. The emphasis will be on research accomplishments and future opportunities, but a comparison will be given of operating characteristics for first, second, and third generation machines. First generation light sources were built to do research with the primary electron and positron beams, rather than with the synchrotron radiation itself. Second generation machines were specifically designed to be dedicated synchrotron-radiation facilities, with an emphasis on the use of bending-magnet radiation. The newmore » third generation light sources are being designed to optimize radiation from insertion devices, such as undulators and wigglers. Each generation of synchrotron light source offers useful capabilities for forefront research in atomic physics and many other disciplines. 27 refs., 1 fig., 3 tabs.« less

  15. Analysis of Shade Matching in Natural Dentitions Using Intraoral Digital Spectrophotometer in LED and Filtered LED Light Sources.

    PubMed

    Chitrarsu, Vijai Krishnan; Chidambaranathan, Ahila Singaravel; Balasubramaniam, Muthukumar

    2017-10-31

    To evaluate the shade matching capabilities in natural dentitions using Vita Toothguide 3D-Master and an intraoral digital spectrophotometer (Vita Easyshade Advance 4.0) in various light sources. Participants between 20 and 40 years old with natural, unrestored right maxillary central incisors, no history of bleaching, orthodontic treatment, or malocclusion and no rotations were included. According to their shades, subjects were randomly selected and grouped into A1, A2, and A3. A total of 100 participants (50 male and 50 female) in each group were chosen for this study. Shade selection was made between 10 am and 2 pm for all light sources. The same examiner selected the shade of natural teeth with Vita Toothguide 3D-Master under natural light within 2 minutes. Once the Vita Toothguide 3D-Masterwas matched with the maxillary right central incisor, the L*, a*, and b* values, chroma, and hue were recorded with Vita Easyshade Advance 4.0 by placing it on the shade tab under the same light source. The values were statistically analyzed using one-way ANOVA and Tukey's HSD post hoc test with SPSS v22.0 software. The mean ∆E* ab values for shades A1, A2, and A3 for groups 1, 2, and 3 were statistically significantly different from each other (p < 0.001). The intraoral digital spectrophotometer showed statistically significant differences in shade matching compared to Vita Toothguide 3D-Master. Incandescent light showed more accurate shade matching than the filtered LED, LED, and daylight. © 2017 by the American College of Prosthodontists.

  16. Large area, surface discharge pumped, vacuum ultraviolet light source

    DOEpatents

    Sze, R.C.; Quigley, G.P.

    1996-12-17

    Large area, surface discharge pumped, vacuum ultraviolet (VUV) light source is disclosed. A contamination-free VUV light source having a 225 cm{sup 2} emission area in the 240-340 nm region of the electromagnetic spectrum with an average output power in this band of about 2 J/cm{sup 2} at a wall-plug efficiency of approximately 5% is described. Only ceramics and metal parts are employed in this surface discharge source. Because of the contamination-free, high photon energy and flux, and short pulse characteristics of the source, it is suitable for semiconductor and flat panel display material processing. 3 figs.

  17. LED backlight system with fiber-optic red, green, blue to white color combiner

    NASA Astrophysics Data System (ADS)

    Kim, Hye R.; Jeong, Yunsong; Lee, Jhang-Woo; Oh, Kyunghwan

    2006-09-01

    As an application in the backlight system of small LCD display, we realized a pure white light source by mixing red, green, blue (RGB) lights using a 3 X 3 Hard Plastic Cladding Fiber (HPCF) coupler. We also proposed the 0.44 inch LED backlight system with these fiber-optic pure white sources and characterized its illumination characteristics. Using optimized fusion-tapering technique, we fabricated HPCF coupler which combines three input lights over the circularly formed waist. HPCF has the core diameter of 200 μm and clad diameter of 230 μm. The fabricated 3 X 3 HPCF coupler has the perfect uniformity of about 0.3 dB, low insertion loss of 5.5 dB, and low excess loss of 0.8 dB, which shows excellent uniform power splitting ratio. In order to improve the transmission performance, The RGB chip LEDs were butt-coupled directly to the ferruled input ports of the coupler and packaged by TO46-can type. In the produced white color by HPCF coupler, the photometric brightness at the circular endface of outputs of HPCF coupler was in a rage of 10062 ~ 10094 cd/m2. The fiber optic white color combiner provides tunable white sources excluding heat source and having thickness of 200 μm. We also proposed a 0.44 inch LED backlight system with these fiber-optic pure white sources. With the proposed device, we obtain the improved uniformity in luminance distribution and wide color gamut by using the white light mixing red, green and blue lights.

  18. The postAIDS structure of students' attitudes to condoms: age, sex and experience of use.

    PubMed

    Sheeran, P; Abraham, S C; Abrams, D; Spears, R; Marks, D

    1990-04-01

    A central aspect of health education campaigns designed to prevent the spread of HIV has been to encourage people to use condoms during sexual intercourse. Little research has, however, been carried out on attitudes towards condoms. The present study investigated the post-AIDS structure of students' attitudes to condoms and examined the association of subjects' age, sex, and experience of use with those attitudes. Subject were students attending a university and a polytechnic in Dundee, Scotland. Out of 600 questionnaires sent out 318 were returned after reminders, a response rate of 53%. Attitudes towards condoms were measured using 8 5-point Likert items. Principal component analysis with varimax rotation produced 3 orthogonal factors accounting for 61.0% of the variance. The factors were labelled Condom Effectiveness (26.3%), Condom Offensiveness (21.0%), and Condom Attractiveness (13.7%). Factor scores were computed by reversing the scoring of items with negative loadings and averaging across items within factors. Condoms were considered quite effective among the present sample (M=4.0, SD+0.6, range=1.5). Subjects also believed, however, that condoms were somewhat offensive (M=3.4, SD=0.6) and unattractive to use (M=2.7, SD=0.8). Women considered condoms more offensive than men (F 1273=11.06, p.001) and subjects who had previously used condoms during sex considered condoms more effective (F1273=4.85, p.05) and less offensive (F1273=12.18, p.001) than those who had never used them. Clearly these concerns about the condom on dimensions of effectiveness, offensiveness and attractiveness might be a barrier to intentions to change behavior and need to be addressed by health education campaigns. Such initiatives must, as Abrams, Abraham, Spears, and Marks (1990) and Abraham, Sheeran, Abrahams, and Spears (in press) point out, be targeted towards the concerns of particular groups such as those examined here. (full text)

  19. Monte Carlo simulation for light propagation in 3D tooth model

    NASA Astrophysics Data System (ADS)

    Fu, Yongji; Jacques, Steven L.

    2011-03-01

    Monte Carlo (MC) simulation was implemented in a three dimensional tooth model to simulate the light propagation in the tooth for antibiotic photodynamic therapy and other laser therapy. The goal of this research is to estimate the light energy deposition in the target region of tooth with given light source information, tooth optical properties and tooth structure. Two use cases were presented to demonstrate the practical application of this model. One case was comparing the isotropic point source and narrow beam dosage distribution and the other case was comparing different incident points for the same light source. This model will help the doctor for PDT design in the tooth.

  20. 43 CFR 15.7 - Fishing.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 43 Public Lands: Interior 1 2014-10-01 2014-10-01 false Fishing. 15.7 Section 15.7 Public Lands: Interior Office of the Secretary of the Interior KEY LARGO CORAL REEF PRESERVE § 15.7 Fishing. (a) Spear fishing within the boundaries or confines of this Preserve is prohibited. (b) The use of poisons, electric...

  1. 43 CFR 15.7 - Fishing.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 43 Public Lands: Interior 1 2013-10-01 2013-10-01 false Fishing. 15.7 Section 15.7 Public Lands: Interior Office of the Secretary of the Interior KEY LARGO CORAL REEF PRESERVE § 15.7 Fishing. (a) Spear fishing within the boundaries or confines of this Preserve is prohibited. (b) The use of poisons, electric...

  2. 43 CFR 15.7 - Fishing.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 43 Public Lands: Interior 1 2012-10-01 2011-10-01 true Fishing. 15.7 Section 15.7 Public Lands: Interior Office of the Secretary of the Interior KEY LARGO CORAL REEF PRESERVE § 15.7 Fishing. (a) Spear fishing within the boundaries or confines of this Preserve is prohibited. (b) The use of poisons, electric...

  3. Putting Anti-Indian Violence in Context. The Case of the Great Lakes Chippewas of Wisconsin

    ERIC Educational Resources Information Center

    Perry, Barbara; Robyn, Linda

    2005-01-01

    The Chippewas of Northern Wisconsin continue to experience a peculiarly American form of apartheid, characterized by segregation, discrimination, cultural imperialism, and everyday violence. While the blatant stigmatization, disempowerment, and violence reached its modern day zenith in the spear fishing conflict of the 1980s and 1990s, ongoing…

  4. 43 CFR 15.7 - Fishing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Fishing. 15.7 Section 15.7 Public Lands: Interior Office of the Secretary of the Interior KEY LARGO CORAL REEF PRESERVE § 15.7 Fishing. (a) Spear fishing within the boundaries or confines of this Preserve is prohibited. (b) The use of poisons, electric...

  5. 43 CFR 15.7 - Fishing.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 1 2011-10-01 2011-10-01 false Fishing. 15.7 Section 15.7 Public Lands: Interior Office of the Secretary of the Interior KEY LARGO CORAL REEF PRESERVE § 15.7 Fishing. (a) Spear fishing within the boundaries or confines of this Preserve is prohibited. (b) The use of poisons, electric...

  6. 50 CFR 27.43 - Weapons other than firearms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 8 2011-10-01 2011-10-01 false Weapons other than firearms. 27.43 Section... (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM PROHIBITED ACTS Disturbing Violations: With Weapons § 27.43 Weapons other than firearms. The use or possession of cross bows, bows and arrows, air guns, spears, gigs...

  7. 50 CFR 27.43 - Weapons other than firearms.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 50 Wildlife and Fisheries 9 2013-10-01 2013-10-01 false Weapons other than firearms. 27.43 Section... (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM PROHIBITED ACTS Disturbing Violations: With Weapons § 27.43 Weapons other than firearms. The use or possession of cross bows, bows and arrows, air guns, spears, gigs...

  8. 50 CFR 27.43 - Weapons other than firearms.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 50 Wildlife and Fisheries 9 2014-10-01 2014-10-01 false Weapons other than firearms. 27.43 Section... (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM PROHIBITED ACTS Disturbing Violations: With Weapons § 27.43 Weapons other than firearms. The use or possession of cross bows, bows and arrows, air guns, spears, gigs...

  9. 50 CFR 27.43 - Weapons other than firearms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 50 Wildlife and Fisheries 9 2012-10-01 2012-10-01 false Weapons other than firearms. 27.43 Section... (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM PROHIBITED ACTS Disturbing Violations: With Weapons § 27.43 Weapons other than firearms. The use or possession of cross bows, bows and arrows, air guns, spears, gigs...

  10. 50 CFR 27.43 - Weapons other than firearms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false Weapons other than firearms. 27.43 Section... (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM PROHIBITED ACTS Disturbing Violations: With Weapons § 27.43 Weapons other than firearms. The use or possession of cross bows, bows and arrows, air guns, spears, gigs...

  11. 50 CFR 665.245 - Gear restrictions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Gear restrictions. (a) Permit Area 1. (1) Lobsters may be taken only with lobster traps or by hand. Lobsters may not be taken by means of poisons, drugs, other chemicals, spears, nets, hook, or explosives. (2) The smallest opening of an entry way of any lobster trap may not allow any sphere or cylinder...

  12. 50 CFR 622.31 - Prohibited gear and methods.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... harvest a Caribbean spiny lobster. The possession of a speared, pierced, or punctured Caribbean spiny lobster in or from the Caribbean EEZ is prima facie evidence of violation of this section. (k) Traps for... may not be used in the Caribbean EEZ to fish for Caribbean reef fish or Caribbean spiny lobster...

  13. The "Ass" Camouflage Construction: Masks as Parasitic Heads

    ERIC Educational Resources Information Center

    Levine, Robert D.

    2010-01-01

    Collins et al. 2008 offers a principles-and-parameters-based analysis of an AAVE construction first described in Spears 1998, in which nominal phrases such as "John's ass" appear to have exactly the same denotation, and behavior with respect to familiar conditions on anaphora, as the possessor ["John," and similarly for pronominal possessors.…

  14. Military Assistance to Mexico: Use of Special Operations Forces

    DTIC Science & Technology

    2010-03-31

    91 Donald Sparks, " Jackal Stone 2009; Special Opcmti011s Forces Multinational Training in Croatia", Tt/J of the Spear, USSCOM, Tampa FL, 92 Sparks...Data Analysis from 2001-2009" Justice in Mexico Project, Trans Border Institute, University of San Diego, January 2009. Sparks, Donald " Jackal Stone

  15. 78 FR 49478 - National Saltwater Angler Registry Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-14

    ... twenty-five dollars ($25.00) for registration of anglers, spear fishers and for-hire fishing vessels to... to twenty-five dollars ($25.00). All persons registering on or after August 1, 2013 will be required to pay that registration fee, unless they are exempt as indigenous people per the provisions of 50...

  16. A Phenomenological Exploration of Self-Directed Learning among Successful Minority Entrepreneurs

    ERIC Educational Resources Information Center

    Alexander, Nancy Hope

    2013-01-01

    This transcendental, phenomenological study explored the Self-directed learning (SDL) of 10 successful minority entrepreneurs. Two SDL theories serve as lenses for the study, Spear and Mocker's (1984) Organizing Circumstance and Brockett and Heimstra's (1991) Personal Responsibility Orientation model. Five themes emerged from the data:…

  17. 75 FR 7361 - Gray's Reef National Marine Sanctuary Regulations on the Use of Spearfishing Gear

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-19

    ... the use of powerheads since the 1981 GRNMS designation, powerhead spear tips and spent shells are... populations. Spearfishing has been shown to remove greater biomass of reef fishes than rod and reel fishing... marine debris. Nevertheless, spearfishing gear and ammunition shells associated with powerhead use have...

  18. Evidence for close-range hunting by last interglacial Neanderthals.

    PubMed

    Gaudzinski-Windheuser, Sabine; Noack, Elisabeth S; Pop, Eduard; Herbst, Constantin; Pfleging, Johannes; Buchli, Jonas; Jacob, Arne; Enzmann, Frieder; Kindler, Lutz; Iovita, Radu; Street, Martin; Roebroeks, Wil

    2018-07-01

    Animal resources have been part of hominin diets since around 2.5 million years ago, with sharp-edged stone tools facilitating access to carcasses. How exactly hominins acquired animal prey and how hunting strategies varied through time and space is far from clear. The oldest possible hunting weapons known from the archaeological record are 300,000 to 400,000-year-old sharpened wooden staves. These may have been used as throwing and/or close-range thrusting spears, but actual data on how such objects were used are lacking, as unambiguous lesions caused by such weapon-like objects are unknown for most of human prehistory. Here, we report perforations observed on two fallow deer skeletons from Neumark-Nord, Germany, retrieved during excavations of 120,000-year-old lake shore deposits with abundant traces of Neanderthal presence. Detailed studies of the perforations, including micro-computed tomography imaging and ballistic experiments, demonstrate that they resulted from the close-range use of thrusting spears. Such confrontational ways of hunting require close cooperation between participants, and over time may have shaped important aspects of hominin biology and behaviour.

  19. Non-kin cooperation in bats

    PubMed Central

    Carter, Gerald G.; Bohn, Kirsten M.; Adams, Danielle M.

    2016-01-01

    Many bats are extremely social. In some cases, individuals remain together for years or even decades and engage in mutually beneficial behaviours among non-related individuals. Here, we summarize ways in which unrelated bats cooperate while roosting, foraging, feeding or caring for offspring. For each situation, we ask if cooperation involves an investment, and if so, what mechanisms might ensure a return. While some cooperative outcomes are likely a by-product of selfish behaviour as they are in many other vertebrates, we explain how cooperative investments can occur in several situations and are particularly evident in food sharing among common vampire bats (Desmodus rotundus) and alloparental care by greater spear-nosed bats (Phyllostomus hastatus). Fieldwork and experiments on vampire bats indicate that sharing blood with non-kin expands the number of possible donors beyond kin and promotes reciprocal help by strengthening long-term social bonds. Similarly, more than 25 years of recapture data and field observations of greater spear-nosed bats reveal multiple cooperative investments occurring within stable groups of non-kin. These studies illustrate how bats can serve as models for understanding how cooperation is regulated in social vertebrates. PMID:26729934

  20. High-pressure and high-temperature neutron reflectometry cell for solid-fluid interface studies

    NASA Astrophysics Data System (ADS)

    Wang, P.; Lerner, A. H.; Taylor, M.; Baldwin, J. K.; Grubbs, R. K.; Majewski, J.; Hickmott, D. D.

    2012-07-01

    A new high pressure-temperature ( P - T Neutron Reflectometry (NR) cell developed at Los Alamos National Laboratory (LANL) is described that significantly extends the capabilities of solid/fluid interface investigations up to 200MPa ( ensuremath ˜ 30000 psi) and 200 ° C. The cell's simple aluminum construction makes it light and easy to operate while thinned neutron windows allow up to 74% neutron transmission. The wide-open neutron window geometry provides a maximum theoretical ensuremath Qz range of 0.31Å-1. Accurate T and P controls are integrated on the cell's control panel. Built-in powder wells provide the ability to saturate fluids with reactive solids, producing aqueous species and/or decomposing into gaseous phases. The cell is designed for samples up to 50.8mm in diameter and 10.0mm in thickness. An experiment investigating the high P - T corrosion behavior of aluminum on LANL's Surface ProfilE Analysis Reflectometer (SPEAR) is presented, demonstrating the functioning and capability of the cell. Finally, outlooks on high P - T NR applications and perspectives on future research are discussed.

  1. A catchment scale evaluation of multiple stressor effects in headwater streams.

    PubMed

    Rasmussen, Jes J; McKnight, Ursula S; Loinaz, Maria C; Thomsen, Nanna I; Olsson, Mikael E; Bjerg, Poul L; Binning, Philip J; Kronvang, Brian

    2013-01-01

    Mitigation activities to improve water quality and quantity in streams as well as stream management and restoration efforts are conducted in the European Union aiming to improve the chemical, physical and ecological status of streams. Headwater streams are often characterised by impairment of hydromorphological, chemical, and ecological conditions due to multiple anthropogenic impacts. However, they are generally disregarded as water bodies for mitigation activities in the European Water Framework Directive despite their importance for supporting a higher ecological quality in higher order streams. We studied 11 headwater streams in the Hove catchment in the Copenhagen region. All sites had substantial physical habitat and water quality impairments due to anthropogenic influence (intensive agriculture, urban settlements, contaminated sites and low base-flow due to water abstraction activities in the catchment). We aimed to identify the dominating anthropogenic stressors at the catchment scale causing ecological impairment of benthic macroinvertebrate communities and provide a rank-order of importance that could help in prioritising mitigation activities. We identified numerous chemical and hydromorphological impacts of which several were probably causing major ecological impairments, but we were unable to provide a robust rank-ordering of importance suggesting that targeted mitigation efforts on single anthropogenic stressors in the catchment are unlikely to have substantial effects on the ecological quality in these streams. The SPEcies At Risk (SPEAR) index explained most of the variability in the macroinvertebrate community structure, and notably, SPEAR index scores were often very low (<10% SPEAR abundance). An extensive re-sampling of a subset of the streams provided evidence that especially insecticides were probably essential contributors to the overall ecological impairment of these streams. Our results suggest that headwater streams should be considered in future management and mitigation plans. Catchment-based management is necessary because several anthropogenic stressors exceeded problematic thresholds, suggesting that more holistic approaches should be preferred. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Effects of light sources and intensity on broilers grown to heavy weights. Part 1: growth performance, carcass characteristics, and welfare indices

    USDA-ARS?s Scientific Manuscript database

    This study investigated the effects of light sources and light intensity on growth performance, carcass characteristics, and welfare indices of heavy broilers (> 3.0 kg) in 4 trials with 2 replications per trial. A total of 960 1-d-old Ross × Ross 708 chicks (30 males/30 females/room) were randomly ...

  3. Ag nanocluster-based color converters for white organic light-emitting devices

    NASA Astrophysics Data System (ADS)

    Nishikitani, Yoshinori; Takizawa, Daisuke; Uchida, Soichi; Lu, Yue; Nishimura, Suzushi; Oyaizu, Kenichi; Nishide, Hiroyuki

    2017-11-01

    The authors present Ag nanocluster-based color converters (Ag NC color converters), which convert part of the blue light from a light source to yellow light so as to create white organic light-emitting devices that could be suitable for lighting systems. Ag NCs synthesized by poly(methacrylic acid) template methods have a statistical size distribution with a mean diameter of around 4.5 nm, which is larger than the Fermi wavelength of around 2 nm. Hence, like free electrons in metals, the Ag NC electrons are thought to form a continuous energy band, leading to the formation of surface plasmons by photoexcitation. As for the fluorescence emission mechanism, the fact that the photoluminescence is excitation wavelength dependent suggests that the fluorescence originates from surface plasmons in Ag NCs of different sizes. By using Ag NC color converters and suitable blue light sources, white organic light-emitting devices can be fabricated based on the concept of light-mixing. For our blue light sources, we used polymer light-emitting electrochemical cells (PLECs), which, like organic light-emitting diodes, are area light sources. The PLECs were fabricated with a blue fluorescent π-conjugated polymer, poly[(9,9-dihexylfluoren-2,7-diyl)-co-(anthracen-9,10-diyl)] (PDHFA), and a polymeric solid electrolyte composed of poly(ethylene oxide) and KCF3SO3. In this device structure, the Ag NC color converter absorbs blue light from the PDHFA-based PLEC (PDHFA-PLEC) and then emits yellow light. When the PDHFA-PLEC is turned on by applying an external voltage, pure white light emission can be produced with Commission Internationale de l'Eclairage coordinates of (x = 0.32, y = 0.33) and a color rendering index of 93.6. This study shows that utilization of Ag NC color converters and blue PLECs is a very promising and highly effective method for realizing white organic light-emitting devices.

  4. Crystal scintillators for use in check-light source for thermoluminescent systems

    NASA Astrophysics Data System (ADS)

    Nagpal, J. S.; Sabharwal, S. C.; Chougaonkar, M. P.; Godbole, S. V.

    1999-08-01

    Beta ( 63Ni, Emax 0.063 MeV) excited radioluminescence of indigenously grown crystal scintillators CsI(Tl), Bi 4Ge 3O 12 and CdWO 4 has been studied for its use in check-light source needed for thermoluminescence systems. Temperature coefficient of the light output over 298-323 K and the beta-induced TL of the scintillators over 298-553 K are reported.

  5. 600 eV falcon-linac thomson x-ray source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crane, J K; LeSage, G P; Ditmire, T

    2000-12-15

    The advent of 3rd generation light sources such as the Advanced Light Source (ALS) at LBL, and the Advanced Photon Source at Argonne, have produced a revolution in x-ray probing of dense matter during the past decade. These machines use electron-synchrotrons in conjunction with undulator stages to produce 100 psec x-ray pulses with photon energies of several kiloelectronvolts (keV). The applications for x-ray probing of matter are numerous and diverse with experiments in medicine and biology, semiconductors and materials science, and plasma and solid state physics. In spite of the success of the 3rd generation light sources there is strongmore » motivation to push the capabilities of x-ray probing into new realms, requiring shorter pulses, higher brightness and harder x-rays. A 4th generation light source, the Linac Coherent Light Source (LCLS), is being considered at the Stanford Linear Accelerator [1]. The LCLS will produce multi-kilovolt x-rays of subpicosecond duration that are 10 orders of magnitude brighter than today's 3rd generation light sources.[1] Although the LCLS will provide unprecedented capability for performing time-resolved x-ray probing of ultrafast phenomena at solid densities, this machine will not be completed for many years. In the meantime there is a serious need for an ultrashort-pulse, high-brightness, hard x-ray source that is capable of probing deep into high-Z solid materials to measure dynamic effects that occur on picosecond time scales. Such an instrument would be ideal for probing the effects of shock propagation in solids using Bragg and Laue diffraction. These techniques can be used to look at phase transitions, melting and recrystallization, and the propagation of defects and dislocations well below the surface in solid materials. [2] These types of dynamic phenomena undermine the mechanical properties of metals and are of general interest in solid state physics, materials science, metallurgy, and have specific relevance to stockpile stewardship. Another x-ray diagnostic technique, extended x-ray absorption fine structure (EXAFS) spectroscopy, can be used to measure small-scale structural changes to understand the underlying atomic physics associated with the formation of defects. [2]« less

  6. Analysis of Servant-Leadership Characteristics: Case Study of a For-Profit Career School President

    ERIC Educational Resources Information Center

    Hiatt, Elaine M.

    2010-01-01

    Servant leadership is a challenging leadership philosophy to study empirically. The purpose of this qualitative descriptive case study was to determine if an effective leader of a for-profit career school displays the 10 servant-leader characteristics, identified by Larry R. Spears (1995) in "Reflections on Leadership," according to respondents,…

  7. A Leg up

    ERIC Educational Resources Information Center

    Henderson, Nancy

    2010-01-01

    This article features Jordan Thomas, who lost his feet in a spear fishing accident in August 2005. It describes how Thomas turned his own loss into a way to help kids get the prosthetics they need. Just three weeks after losing his feet, Thomas filed the paperwork for the Jordan Thomas Foundation, which aims to raise funds for prosthetic limbs for…

  8. Cyber Exercise Playbook

    DTIC Science & Technology

    2014-11-01

    unclassified tools and techniques that can be shared with PNs, to include social engineering, spear phishing , fake web sites, physical access attempts, and...and instead rely on commercial services such as Yahoo or Google . Some nations have quite advanced cyber security practices, but may take vastly...unauthorized access to data/systems Inject external network scanning, email phishing , malicious website access, social engineering Sample

  9. Experience of Presence in Virtual Environments

    DTIC Science & Technology

    2003-09-01

    perceptual position (exocentric, egocentric) neurolinguistic programming (NLP) assessment. Performance measures: Selection of correct spear, accuracy...the future. Accordingly, the Institute for Defense Analyses (IDA) is undertaking an analysis program to determine whether current data are sufficient...Many groups are seeking a better understanding of presence. From its start, IDA’s program has included pulling together the results of these efforts to

  10. Fostering Protective Factors in At-Risk Youth Using Individual and Group Counseling Interventions

    ERIC Educational Resources Information Center

    Wright-Cunningham, Kamal Phillip

    2012-01-01

    Adolescence is a time when individuals are forced to deal with the stress of moving from being a teenager to an adult (Spear, 2000). As a result, this difficult developmental period is often characterized by adolescents engaging in risky behavior and potentially dangerous experimentation (Golden & Turner, 2005). The importance of understanding how…

  11. Observations on the entomopathogenic fungus Hirsutella citriformis attacking adult Diaphorina citri (Hemiptera: Psyllid) in a managed citrus grove

    USDA-ARS?s Scientific Manuscript database

    A two-year field study was conducted in an orange grove (0.7 ha) in Florida to characterize the phenology of the entomopathogen Hirsutella citriformis Speare infecting adults of the Asian citrus psyllid, Diaphorina citri Kuwayama. On the average over the two-year study, 23 percent of adults observed...

  12. Examining the Impact of Servant Leadership on Workplace Related Outcome (JS) at a Selected Private University

    ERIC Educational Resources Information Center

    Guillaume, Oris

    2012-01-01

    The aim of this study was to examine the impact of Servant Leadership on a workplace related outcome (job satisfaction) at a private University in Atlanta, Georgia. The ten characteristics of Servant Leadership previously identified by Greenleaf (1977) and Spears (1998) played a significant role in job satisfaction. Other researchers (Barbuto…

  13. "The Pen is the Spear of Today": (Re)producing Gender in the Maasai Schooling Setting

    ERIC Educational Resources Information Center

    Archambault, Caroline S.

    2017-01-01

    An essentialist, "traditional", Maasai gender ideology that poorly reflects the day-to-day gender realities of residents is being reproduced and dominating in the modern schooling setting of a Maasai community in Southern Kenya. Through an ethnographic analysis based on long-term fieldwork and mixed-method approaches, this paper explores…

  14. Dr. Mary McLeod Bethune: A Life Devoted to Service

    ERIC Educational Resources Information Center

    Long, Kim Cliett

    2011-01-01

    The purpose of this paper is to explore and analyze the leadership traits of Dr. Mary McLeod Bethune, an African-American woman of history, using the servant leadership theory developed by Robert K. Greenberg and the ten characteristics of servant leadership as conceived by Larry C. Spears. This exploration seeks to identify the significant…

  15. 46 CFR 112.35-3 - Normal source for emergency loads.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....35-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Manually Controlled Emergency Systems Having a Storage Battery or a Diesel Engine or Gas Turbine Driven Generator as the Sole Emergency Power Source § 112.35-3 Normal source...

  16. 46 CFR 112.35-3 - Normal source for emergency loads.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....35-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Manually Controlled Emergency Systems Having a Storage Battery or a Diesel Engine or Gas Turbine Driven Generator as the Sole Emergency Power Source § 112.35-3 Normal source...

  17. 46 CFR 112.35-3 - Normal source for emergency loads.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....35-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Manually Controlled Emergency Systems Having a Storage Battery or a Diesel Engine or Gas Turbine Driven Generator as the Sole Emergency Power Source § 112.35-3 Normal source...

  18. 46 CFR 112.35-3 - Normal source for emergency loads.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ....35-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Manually Controlled Emergency Systems Having a Storage Battery or a Diesel Engine or Gas Turbine Driven Generator as the Sole Emergency Power Source § 112.35-3 Normal source...

  19. 46 CFR 112.35-3 - Normal source for emergency loads.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....35-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Manually Controlled Emergency Systems Having a Storage Battery or a Diesel Engine or Gas Turbine Driven Generator as the Sole Emergency Power Source § 112.35-3 Normal source...

  20. Wavelength-Resolved Photon Fluxes of Indoor Light Sources: Implications for HOx Production

    NASA Astrophysics Data System (ADS)

    Kowal, S.; Kahan, T.

    2017-12-01

    Only a handful of studies have considered photolytic reactions indoors because photon fluxes at short wavelengths are generally considered to be negligible. We have measured wavelength resolved photon fluxes from indoor light sources including incandescent, halogen, compact fluorescent (CFL), and light emitting diodes (LED). In addition, fluorescent tubes, used in many offices and industrial buildings, and sunlight through windows were measured. The measured photon fluxes were used to calculate photolysis rate constants for potential indoor hydroxyl and peroxy radical (OH and HO2, "HOx") precursors: acetaldehyde (CH3CHO), formaldehyde (HCHO), hydrogen peroxide (H2O2), nitrous acid (HONO) and ozone (O3). Rate constants in conjunction with typical indoor concentrations were used to predict HOx production rates under various lighting conditions. Our results illustrate that all light sources except LEDs emit light at high enough energy to photolyze HOx precursors. Under typical lighting conditions only fluorescent tubes and sunlight will initiate significant photochemical HOx formation, and HONO and HCHO will be the only molecules that will have a strong influence on HOx levels indoors. Data from our experiments can be used in indoor air models to better predict HOx levels indoors.

  1. Non-invasive three-dimension control of light between turbid layers using a surface quasi-point light source for precorrection.

    PubMed

    Qiao, Mu; Liu, Honglin; Pang, Guanghui; Han, Shensheng

    2017-08-29

    Manipulating light non-invasively through inhomogeneous media is an attractive goal in many disciplines. Wavefront shaping and optical phase conjugation can focus light to a point. Transmission matrix method can control light on multiple output modes simultaneously. Here we report a non-invasive approach which enables three-dimension (3D) light control between two turbid layers. A digital optical phase conjugation mirror measured and conjugated the diffused wavefront, which originated from a quasi-point source on the front turbid layer and passed through the back turbid layer. And then, because of memory effect, the phase-conjugated wavefront could be used as a carrier wave to transport a pre-calculated wavefront through the back turbid layer. The pre-calculated wavefront could project a desired 3D light field inside the sample, which, in our experiments, consisted of two 220-grid ground glass plates spaced by a 20 mm distance. The controllable range of light, according to the memory effect, was calculated to be 80 mrad in solid angle and 16 mm on z-axis. Due to the 3D light control ability, our approach may find applications in photodynamic therapy and optogenetics. Besides, our approach can also be combined with ghost imaging or compressed sensing to achieve 3D imaging between turbid layers.

  2. Scannerless laser range imaging using loss modulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sandusky, John V

    2011-08-09

    A scannerless 3-D imaging apparatus is disclosed which utilizes an amplitude modulated cw light source to illuminate a field of view containing a target of interest. Backscattered light from the target is passed through one or more loss modulators which are modulated at the same frequency as the light source, but with a phase delay .delta. which can be fixed or variable. The backscattered light is demodulated by the loss modulator and detected with a CCD, CMOS or focal plane array (FPA) detector to construct a 3-D image of the target. The scannerless 3-D imaging apparatus, which can operate inmore » the eye-safe wavelength region 1.4-1.7 .mu.m and which can be constructed as a flash LADAR, has applications for vehicle collision avoidance, autonomous rendezvous and docking, robotic vision, industrial inspection and measurement, 3-D cameras, and facial recognition.« less

  3. Scannerless laser range imaging using loss modulation

    DOEpatents

    Sandusky, John V [Albuquerque, NM

    2011-08-09

    A scannerless 3-D imaging apparatus is disclosed which utilizes an amplitude modulated cw light source to illuminate a field of view containing a target of interest. Backscattered light from the target is passed through one or more loss modulators which are modulated at the same frequency as the light source, but with a phase delay .delta. which can be fixed or variable. The backscattered light is demodulated by the loss modulator and detected with a CCD, CMOS or focal plane array (FPA) detector to construct a 3-D image of the target. The scannerless 3-D imaging apparatus, which can operate in the eye-safe wavelength region 1.4-1.7 .mu.m and which can be constructed as a flash LADAR, has applications for vehicle collision avoidance, autonomous rendezvous and docking, robotic vision, industrial inspection and measurement, 3-D cameras, and facial recognition.

  4. On-Chip Waveguide Coupling of a Layered Semiconductor Single-Photon Source.

    PubMed

    Tonndorf, Philipp; Del Pozo-Zamudio, Osvaldo; Gruhler, Nico; Kern, Johannes; Schmidt, Robert; Dmitriev, Alexander I; Bakhtinov, Anatoly P; Tartakovskii, Alexander I; Pernice, Wolfram; Michaelis de Vasconcellos, Steffen; Bratschitsch, Rudolf

    2017-09-13

    Fully integrated quantum technology based on photons is in the focus of current research, because of its immense potential concerning performance and scalability. Ideally, the single-photon sources, the processing units, and the photon detectors are all combined on a single chip. Impressive progress has been made for on-chip quantum circuits and on-chip single-photon detection. In contrast, nonclassical light is commonly coupled onto the photonic chip from the outside, because presently only few integrated single-photon sources exist. Here, we present waveguide-coupled single-photon emitters in the layered semiconductor gallium selenide as promising on-chip sources. GaSe crystals with a thickness below 100 nm are placed on Si 3 N 4 rib or slot waveguides, resulting in a modified mode structure efficient for light coupling. Using optical excitation from within the Si 3 N 4 waveguide, we find nonclassicality of generated photons routed on the photonic chip. Thus, our work provides an easy-to-implement and robust light source for integrated quantum technology.

  5. 46 CFR 129.440 - Emergency lighting.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... working (machinery) spaces below the main deck. (b) The emergency lighting required by paragraph (a) of... with a single source of power for emergency lighting, it must have individual battery-powered lighting that is— (1) Automatically actuated upon loss of normal power; (2) Not readily portable; (3) Connected...

  6. 46 CFR 129.440 - Emergency lighting.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... working (machinery) spaces below the main deck. (b) The emergency lighting required by paragraph (a) of... with a single source of power for emergency lighting, it must have individual battery-powered lighting that is— (1) Automatically actuated upon loss of normal power; (2) Not readily portable; (3) Connected...

  7. 46 CFR 129.440 - Emergency lighting.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... working (machinery) spaces below the main deck. (b) The emergency lighting required by paragraph (a) of... with a single source of power for emergency lighting, it must have individual battery-powered lighting that is— (1) Automatically actuated upon loss of normal power; (2) Not readily portable; (3) Connected...

  8. 46 CFR 129.440 - Emergency lighting.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... working (machinery) spaces below the main deck. (b) The emergency lighting required by paragraph (a) of... with a single source of power for emergency lighting, it must have individual battery-powered lighting that is— (1) Automatically actuated upon loss of normal power; (2) Not readily portable; (3) Connected...

  9. LPP-EUV light source for HVM lithography

    NASA Astrophysics Data System (ADS)

    Saito, T.; Ueno, Y.; Yabu, T.; Kurosawa, A.; Nagai, S.; Yanagida, T.; Hori, T.; Kawasuji, Y.; Abe, T.; Kodama, T.; Nakarai, H.; Yamazaki, T.; Mizoguchi, H.

    2017-01-01

    We have been developing a laser produced plasma extremely ultra violet (LPP-EUV) light source for a high volume manufacturing (HVM) semiconductor lithography. It has several unique technologies such as the high power short pulse carbon dioxide (CO2) laser, the short wavelength solid-state pre-pulse laser and the debris mitigation technology with the magnetic field. This paper presents the key technologies for a high power LPP-EUV light source. We also show the latest performance data which is 188W EUV power at intermediate focus (IF) point with 3.7% conversion efficiency (CE) at 100 kHz.

  10. Synthesis of labeled compounds using recovered tritium from expired beta light sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matei, L.; Postolache, C.; Bubueanu, G.

    2008-07-15

    In this paper, the technological procedures for extracting tritium from beta light source are highlighted. The recovered tritium was used in the synthesis of organically labeled compounds and in the preparation of tritiated water (HTO) with high specific activity. Technological procedures for treatment of beta light sources consist of: envelope breaking into evacuated enclosure, the radioactive gaseous mixture pumping and its storage on metallic sodium. The mixtures of T{sub 2} and {sup 3}He were used in the synthesis of tritium labeled steroid hormones, nucleosides analogues and for the preparation of HTO with high radioactivity concentrations. (authors)

  11. The efficient model to define a single light source position by use of high dynamic range image of 3D scene

    NASA Astrophysics Data System (ADS)

    Wang, Xu-yang; Zhdanov, Dmitry D.; Potemin, Igor S.; Wang, Ying; Cheng, Han

    2016-10-01

    One of the challenges of augmented reality is a seamless combination of objects of the real and virtual worlds, for example light sources. We suggest a measurement and computation models for reconstruction of light source position. The model is based on the dependence of luminance of the small size diffuse surface directly illuminated by point like source placed at a short distance from the observer or camera. The advantage of the computational model is the ability to eliminate the effects of indirect illumination. The paper presents a number of examples to illustrate the efficiency and accuracy of the proposed method.

  12. The Gaussian Plasma Lens in Astrophysics: Refraction

    NASA Astrophysics Data System (ADS)

    Clegg, Andrew W.; Fey, Alan L.; Lazio, T. Joseph W.

    1998-03-01

    We present the geometrical optics for refraction of a distant background radio source by an interstellar plasma lens, with specific application to a lens with a Gaussian profile of free-electron column density. The refractive properties of the lens are specified completely by a dimensionless parameter α, which is a function of the wavelength of observation, the free-electron column density through the lens, the lens-observer distance, and the diameter of the lens transverse to the line of sight. A lens passing between the observer and a background source, due to the relative motions of the observer, lens, and source, produces modulations in the light curve of the background source. Because plasma lenses are diverging, the light curve displays a minimum in the background source's flux density, formed when the lens is on-axis, surrounded by enhancements above the nominal (unlensed) flux density. The exact form of the light curve depends only upon the parameter α and the relative angular sizes of the source and lens as seen by the observer. Other effects due to lensing include the following: (1) the formation of caustic surfaces, upon which the apparent brightness of the background source becomes very large; (2) the possible creation of multiple images of the background source; and (3) angular position wander of the background source. If caustics are formed, the separation of the outer caustics can be used to constrain α, while the separation of the inner caustics can constrain the size of the lens. We apply our analysis to two sources, which have undergone extreme scattering events: (1) 0954+658, a source for which we can identify multiple caustics in its light curve, and (2) 1741-038, for which polarization observations were obtained during and after the scattering event. We find general agreement between modeled and observed light curves at 2.25 GHz, but poor agreement at 8.1 GHz. The discrepancies between the modeled and observed light curves may result from some combination of substructure within the lens, an anisotropic lens shape, a lens which only grazes the source rather than passing completely over it, or unresolved substructure within the extragalactic sources. Our analysis also allows us to place constraints on the physical characteristics of the lens. The inferred properties of the lens responsible for the scattering event toward 0954+658 (1741-038) are that it was 0.38 AU (0.065 AU) in diameter with a peak column density of 0.24 pc cm-3 (10-4 pc cm-3), an electron density within the lens of 105 cm-3 (300 cm-3), and a mass of 6.5 × 10-14 M⊙ (10-18 M⊙). The angular position wander caused by the lens was 250 mas (0.4 mas) at 2.25 GHz. In the case of 1741-038, we can place an upper limit of only 100 mG on the magnetic field within the lens.

  13. 78 FR 15338 - Fisheries of the Caribbean, Gulf of Mexico, and South Atlantic; Reef Fish Fishery of Puerto Rico...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-11

    ... (generally female) parrotfish, thereby enhancing spawning biomass and the supply of gametes (especially eggs... St. Croix parrotfish ACL and cannot mitigate for losses of landings due to discarded and not speared... would result in an estimated annual loss of parrotfish landings between 960 lb (435 kg) and 13,920 lb (6...

  14. Assessing the General Education Elephant

    ERIC Educational Resources Information Center

    Eubanks, David A.

    2008-01-01

    Determining the success of a general education program can resemble the task of John Godfrey's six blind men in trying to acquaint themselves with an elephant. One man's approach is to feel the tusk and conclude that the elephant is a spear. Another approach leads to thinking that the broad side of the animal is a wall. The many ways of asking and…

  15. Ground penetrating radar for asparagus detection

    NASA Astrophysics Data System (ADS)

    Seyfried, Daniel; Schoebel, Joerg

    2016-03-01

    Ground penetrating radar is a promising technique for detection of buried objects. Recently, radar has more and more been identified to provide benefits for a plurality of applications, where it can increase efficiency of operation. One of these fields is the industrial automatic harvesting process of asparagus, which is performed so far by cutting the soil ridge at a certain height including all the asparagus spears and subsequently sieving the latter out of the soil. However, the height where the soil is cut is a critical parameter, since a wrong value leads to either damage of the roots of the asparagus plants or to a reduced crop yield as a consequence of too much biomass remaining in the soil. In this paper we present a new approach which utilizes ground penetrating radar for non-invasive sensing in order to obtain information on the optimal height for cutting the soil. Hence, asparagus spears of maximal length can be obtained, while keeping the roots at the same time undamaged. We describe our radar system as well as the subsequent digital signal processing steps utilized for extracting the information required from the recorded radar data, which then can be fed into some harvesting unit for setting up the optimal cutting height.

  16. Acting in solidarity: Testing an extended dual pathway model of collective action by bystander group members.

    PubMed

    Saab, Rim; Tausch, Nicole; Spears, Russell; Cheung, Wing-Yee

    2015-09-01

    We examined predictors of collective action among bystander group members in solidarity with a disadvantaged group by extending the dual pathway model of collective action, which proposes one efficacy-based and one emotion-based path to collective action (Van Zomeren, Spears, Fischer, & Leach, 2004). Based on two proposed functions of social identity performance (Klein, Spears, & Reicher, 2007), we distinguished between the efficacy of collective action at consolidating the identity of a protest movement and its efficacy at achieving social change (political efficacy). We expected identity consolidation efficacy to positively predict collective action tendencies directly and indirectly via political efficacy. We also expected collective action tendencies to be positively predicted by moral outrage and by sympathy in response to disadvantaged outgroup's suffering. These hypotheses were supported in two surveys examining intentions to protest for Palestine in Britain (Study 1), and intentions to attend the June 4th vigil in Hong Kong to commemorate the Tiananmen massacre among a sample of Hong Kong citizens (Study 2). The contributions of these findings to research on the dual pathway model of collective action and the different functions of collective action are discussed. © 2014 The British Psychological Society.

  17. 46 CFR 112.20-3 - Normal source for emergency loads.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....20-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having a Temporary and a Final Emergency Power Source...'s service generating plant. (b) The power from the ship's service generating plant for the emergency...

  18. 46 CFR 112.20-3 - Normal source for emergency loads.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....20-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having a Temporary and a Final Emergency Power Source...'s service generating plant. (b) The power from the ship's service generating plant for the emergency...

  19. 46 CFR 112.20-3 - Normal source for emergency loads.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....20-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having a Temporary and a Final Emergency Power Source...'s service generating plant. (b) The power from the ship's service generating plant for the emergency...

  20. 46 CFR 112.20-3 - Normal source for emergency loads.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ....20-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having a Temporary and a Final Emergency Power Source...'s service generating plant. (b) The power from the ship's service generating plant for the emergency...

  1. 46 CFR 112.20-3 - Normal source for emergency loads.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....20-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Systems Having a Temporary and a Final Emergency Power Source...'s service generating plant. (b) The power from the ship's service generating plant for the emergency...

  2. Narrowband infrared emitters for combat ID

    NASA Astrophysics Data System (ADS)

    Pralle, Martin U.; Puscasu, Irina; Daly, James; Fallon, Keith; Loges, Peter; Greenwald, Anton; Johnson, Edward

    2007-04-01

    There is a strong desire to create narrowband infrared light sources as personnel beacons for application in infrared Identify Friend or Foe (IFF) systems. This demand has augmented dramatically in recent years with the reports of friendly fire casualties in Afghanistan and Iraq. ICx Photonics' photonic crystal enhanced TM (PCE TM) infrared emitter technology affords the possibility of creating narrowband IR light sources tuned to specific IR wavebands (near 1-2 microns, mid 3-5 microns, and long 8-12 microns) making it the ideal solution for infrared IFF. This technology is based on a metal coated 2D photonic crystal of air holes in a silicon substrate. Upon thermal excitation the photonic crystal modifies the emitted yielding narrowband IR light with center wavelength commensurate with the periodicity of the lattice. We have integrated this technology with microhotplate MEMS devices to yield 15mW IR light sources in the 3-5 micron waveband with wall plug efficiencies in excess of 10%, 2 orders of magnitude more efficient that conventional IR LEDs. We have further extended this technology into the LWIR with a light source that produces 9 mW of 8-12 micron light at an efficiency of 8%. Viewing distances >500 meters were observed with fielded camera technologies, ideal for ground to ground troop identification. When grouped into an emitter panel, the viewing distances were extended to 5 miles, ideal for ground to air identification.

  3. Commissioning and Early Operation for the NSLS-II Booster RF System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marques, C.; Cupolo, J.; Davila, P.

    2015-05-03

    The National Synchrotron Light Source II (NSLS-II) at Brookhaven National Laboratory (BNL) is a third generation 3GeV, 500mA synchrotron light source. We discuss the booster synchrotron RF system responsible for providing power to accelerate an electron beam from 200MeV to 3GeV. The RF system design and construction are complete and is currently in the operational phase of the NSLS-II project. Preliminary operational data is also discussed.

  4. An aluminium nitride light-emitting diode with a wavelength of 210 nanometres.

    PubMed

    Taniyasu, Yoshitaka; Kasu, Makoto; Makimoto, Toshiki

    2006-05-18

    Compact high-efficiency ultraviolet solid-state light sources--such as light-emitting diodes (LEDs) and laser diodes--are of considerable technological interest as alternatives to large, toxic, low-efficiency gas lasers and mercury lamps. Microelectronic fabrication technologies and the environmental sciences both require light sources with shorter emission wavelengths: the former for improved resolution in photolithography and the latter for sensors that can detect minute hazardous particles. In addition, ultraviolet solid-state light sources are also attracting attention for potential applications in high-density optical data storage, biomedical research, water and air purification, and sterilization. Wide-bandgap materials, such as diamond and III-V nitride semiconductors (GaN, AlGaN and AlN; refs 3-10), are potential materials for ultraviolet LEDs and laser diodes, but suffer from difficulties in controlling electrical conduction. Here we report the successful control of both n-type and p-type doping in aluminium nitride (AlN), which has a very wide direct bandgap of 6 eV. This doping strategy allows us to develop an AlN PIN (p-type/intrinsic/n-type) homojunction LED with an emission wavelength of 210 nm, which is the shortest reported to date for any kind of LED. The emission is attributed to an exciton transition, and represents an important step towards achieving exciton-related light-emitting devices as well as replacing gas light sources with solid-state light sources.

  5. Sources and Levels of PCBs in Indoor Environments

    EPA Science Inventory

    Source assessment• Primary sources – caulk and light ballasts (6 schools)• Secondary sources – paint, tile, furnishings, etc. (3 schools)• Emission rate estimation Environmental levels (6 schools except dust)• Air, surface, dust, soil PCB c...

  6. Thermal injury secondary to laparoscopic fiber-optic cables.

    PubMed

    Hindle, A Katharine; Brody, Fred; Hopkins, Vernon; Rosales, Greg; Gonzalez, Florencia; Schwartz, Arnold

    2009-08-01

    Laparoscopy requires a reliable light source to provide adequate visualization. However, thermal energy is produced as a by-product from the optical cable. This study attempts to quantify the degree of possible thermal damage secondary to the fiber-optic light source. Using a digital thermometer, temperature measurements were recorded at the tip of optical cables from five different light sources (Karl Storz, Inc., Tuttlingen, Germany). Temperature measurements were recorded with new and old bulbs. The tip of the cable was applied to surgical drapes and the time to charring was recorded. Subsequently, the tip of the optical cable was applied to a porcine model and tissue samples were obtained after varying amounts of time (5, 15, 30, 60, and 90 s). Sections of the damaged tissue were prepared for microscopic evaluation. Parameters for thermal injury included extent of epidermal, dermal, and subcutaneous fat damage and necrosis. The lateral extent and depth of injury were measured. The maximum temperature at the tip of the optical cable varied between 119.5 degrees C and 268.6 degrees C. When surgical drapes were exposed to the tip of the light source, the time to char was 3-6 s. The degree and volume of injury increased with longer exposure times, and significant injury was recorded with the optical cable 3 mm from the skin. This study demonstrates that the temperature at the tip of the optical light cord can induce extensive damage. The by-product of light, heat, can produce immediate superficial tissue necrosis that can extend into the subcutaneous fat even when the optical tip is not in direct contact with the skin. In addition, our study shows the variation in temperature that exists between light sources and bulb status. Overall, surgeons must realize and respect the potential complications associated with optical technology.

  7. Using the Overhead Projector as a Light Source for Physics Demonstrations

    ERIC Educational Resources Information Center

    Mak, Se-Yuen

    2006-01-01

    This article illustrates how the overhead projector can be used as a light source in some peculiar ways for physics demonstrations. Five examples are included: (1) Study of chromatic aberration; (2) Making giant Newton's rings; (3) Comparison of the rate of heat absorption by different surfaces; (4) Demonstration of greenhouse effect; and (5)…

  8. LED-based UV source for monitoring spectroradiometer properties

    NASA Astrophysics Data System (ADS)

    Sildoja, Meelis-Mait; Nevas, Saulius; Kouremeti, Natalia; Gröbner, Julian; Pape, Sven; Pendsa, Stefan; Sperfeld, Peter; Kemus, Fabian

    2018-06-01

    A compact and stable UV monitoring source based on state-of-the-art commercially available ultraviolet light emitting diodes (UV-LEDs) has been developed. It is designed to trace the radiometric stability—both responsivity and wavelength scale—of array spectroradiometers measuring direct solar irradiance in the wavelength range between 300 nm and 400 nm. The spectral irradiance stability of the UV-LED-based light source observed in the laboratory after seasoning (burning-in) the individual LEDs was better than 0.3% over a 12 h period of continuous operation. The integral irradiance measurements of the source over a period of several months, where the UV-LED source was not operated continuously between the measurements, showed stability within 0.3%. In-field measurements of the source with an array spectroradiometer indicated the stability of the source to be within the standard uncertainty of the spectroradiometer calibration, which was within 1% to 2%.

  9. Does the light source affect the repairability of composite resins?

    PubMed

    Karaman, Emel; Gönülol, Nihan

    2014-01-01

    The aim of this study was to examine the effect of the light source on the microshear bond strength of different composite resins repaired with the same substrate. Thirty cylindrical specimens of each composite resin--Filtek Silorane, Filtek Z550 (3M ESPE), Gradia Direct Anterior (GC), and Aelite Posterior (BISCO)--were prepared and light-cured with a QTH light curing unit (LCU). The specimens were aged by thermal cycling and divided into three subgroups according to the light source used--QTH, LED, or PAC (n = 10). They were repaired with the same substrate and a Clearfil Repair Kit (Kuraray). The specimens were light-cured and aged for 1 week in distilled water at 37 °C. The microshear bond strength and failure modes were assessed. There was no significant difference in the microshear bond strength values among the composite resins, except for the Filtek Silorane group that showed significantly lower bond strength values when polymerized with the PAC unit compared to the QTH or LED unit. In conclusion, previously placed dimethacrylate-based composites can be repaired with different light sources; however, if the composite to be repaired is silorane-based, then using a QTH or LED device may be the best option.

  10. Novel wafer stepper with violet LED light source

    NASA Astrophysics Data System (ADS)

    Ting, Yung-Chiang; Shy, Shyi-Long

    2014-03-01

    Novel wafer stepper by using contact or proximity printing will be developed, using violet LED light source to replace Hg Arc. lamp or laser. Mirror, filter and condenser lens for Hg Arc. Lamp or laser and reduction lens for projection printing can be discarded. Reliability and manufacturing cost of wafer stepper can be improved. Exposure result by using IP3600 resist and wafer stepper with violet LED light source (wave-length 360nm to 410 nm) will be obtained. This novel wafer stepper can be used for 3DIC, MEMS and bio-chip lithography application by using thin and thick resist with sub-micron to 100 micron thickness.

  11. Two-mode squeezed light source for quantum illumination and quantum imaging

    NASA Astrophysics Data System (ADS)

    Masada, Genta

    2015-09-01

    We started to research quantum illumination radar and quantum imaging by utilizing high quality continuous-wave two-mode squeezed light source as a quantum entanglement resource. Two-mode squeezed light is a macroscopic quantum entangled state of the electro-magnetic field and shows strong correlation between quadrature phase amplitudes of each optical field. One of the most effective methods to generate two-mode squeezed light is combining two independent single-mode squeezed lights by using a beam splitter with relative phase of 90 degrees between each optical field. As a first stage of our work we are developing two-mode squeezed light source for exploring the possibility of quantum illumination radar and quantum imaging. In this article we introduce current development of experimental investigation of single-mode squeezed light. We utilize a sub-threshold optical parametric oscillator with bow-tie configuration which includes a periodically-polled potassium titanyl phosphate crystal as a nonlinear optical medium. We observed the noise level of squeezed quadrature -3.08+/-0.13 dB and anti-squeezed quadrature at 9.29+/-0.13 dB, respectively. We also demonstrated the remote tuning of squeezing level of the light source which leads to the technology for tuning the quantum entanglement in order to adapt to the actual environmental condition.

  12. Visual color matching system based on RGB LED light source

    NASA Astrophysics Data System (ADS)

    Sun, Lei; Huang, Qingmei; Feng, Chen; Li, Wei; Wang, Chaofeng

    2018-01-01

    In order to study the property and performance of LED as RGB primary color light sources on color mixture in visual psychophysical experiments, and to find out the difference between LED light source and traditional light source, a visual color matching experiment system based on LED light sources as RGB primary colors has been built. By simulating traditional experiment of metameric color matching in CIE 1931 RGB color system, it can be used for visual color matching experiments to obtain a set of the spectral tristimulus values which we often call color-matching functions (CMFs). This system consists of three parts: a monochromatic light part using blazed grating, a light mixing part where the summation of 3 LED illuminations are to be visually matched with a monochromatic illumination, and a visual observation part. The three narrow band LEDs used have dominant wavelengths of 640 nm (red), 522 nm (green) and 458 nm (blue) respectively and their intensities can be controlled independently. After the calibration of wavelength and luminance of LED sources with a spectrophotometer, a series of visual color matching experiments have been carried out by 5 observers. The results are compared with those from CIE 1931 RGB color system, and have been used to compute an average locus for the spectral colors in the color triangle, with white at the center. It has been shown that the use of LED is feasible and has the advantages of easy control, good stability and low cost.

  13. High-energy and ultra-wideband tunable terahertz source with DAST crystal via difference frequency generation

    NASA Astrophysics Data System (ADS)

    He, Yixin; Wang, Yuye; Xu, Degang; Nie, Meitong; Yan, Chao; Tang, Longhuang; Shi, Jia; Feng, Jiachen; Yan, Dexian; Liu, Hongxiang; Teng, Bing; Feng, Hua; Yao, Jianquan

    2018-01-01

    We have demonstrated a high-energy and broadly tunable monochromatic terahertz (THz) source based on difference frequency generation (DFG) in DAST crystal. A high-energy dual-wavelength optical parametric oscillator with two KTP crystals was constructed as a light source for DFG, where the effect of blue light was first observed accompanying with tunable dual-wavelength pump light due to different nonlinear processes. The THz frequency was tuned randomly in the range of 0.3-19.6 THz. The highest energy of 870 nJ/pulse was obtained at 18.9 THz under the intense pump intensity of 247 MW/cm2. The THz energy dips above 3 THz have been analyzed and mainly attributed to the resonance absorption induced by lattice vibration in DAST crystal. The dependence of THz output on the input energy was studied experimentally, and THz output saturation was observed. Furthermore, tests of transmission spectroscopy of four typical samples were demonstrated with this ultra-wideband THz source.

  14. A Three-Stage Model of Housing Search,

    DTIC Science & Technology

    1980-05-01

    Hanushek and Quigley, 1978) that recognize housing search as a transaction cost but rarely - .. examine search behavior; and descriptive studies of search...explicit mobility models that have recently appeared in the liter- ature (Speare et al., 1975; Hanushek and Quigley, 1978; Brummell, 1979). Although...1978; Hanushek and Quigley, 1978; Cronin, 1978). By explicitly assigning dollar values, the economic models attempt to obtain an objective measure of

  15. AN INVESTIGATION OF POISONOUS AND VENOMOUS FISHES AT PALMYRA ISLAND, LINE ISLANDS, DURING 13 APRIL TO 2 MAY 1953

    DTIC Science & Technology

    puffers were edible . Collections were made in April during the reproduction period when toxicity was at a maximum. Hook and line, spear, dynamite, and...flavimarginatus; the sea bass Variola louti; the pomacentrids Abudefduf spp. and lethrinids. Underwater movies were taken for food chain studies. A shipment of reef fishes of Fanning Island was also procured.

  16. Recovery from Fatigue

    DTIC Science & Technology

    1973-06-30

    functioning to replace sleep or recover from fatigue. Possibly the hypnagogic period of descending Stage I, apparently perceived differently S-1 of...partly to quality of mentation during the Stage I hypnagogic period. It may well be that nappers belong to the group described by Foulkes, Spear, and...Symonds (1966) who engage in hypnagogic mentation, and this is clearly perceived by them as different from sleep. The present study suggests that napping

  17. 46 CFR 28.355 - Main source of electrical power.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... auxiliaries and controls; (2) Interior lighting; (3) Steering systems; (4) Communication systems; (5) Navigation equipment and navigation lights; (6) Fire protection or detection equipment; (7) Bilge pumps; or...

  18. 46 CFR 28.355 - Main source of electrical power.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... auxiliaries and controls; (2) Interior lighting; (3) Steering systems; (4) Communication systems; (5) Navigation equipment and navigation lights; (6) Fire protection or detection equipment; (7) Bilge pumps; or...

  19. 46 CFR 28.850 - Main source of electrical power.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... controls; (2) Interior lighting; (3) Steering systems; (4) Communication systems; (5) Navigation equipment and navigation lights; (6) Fire protection or detection equipment; (7) Bilge pumps; and (8) General...

  20. 46 CFR 28.850 - Main source of electrical power.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... controls; (2) Interior lighting; (3) Steering systems; (4) Communication systems; (5) Navigation equipment and navigation lights; (6) Fire protection or detection equipment; (7) Bilge pumps; and (8) General...

  1. 46 CFR 28.355 - Main source of electrical power.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... auxiliaries and controls; (2) Interior lighting; (3) Steering systems; (4) Communication systems; (5) Navigation equipment and navigation lights; (6) Fire protection or detection equipment; (7) Bilge pumps; or...

  2. 46 CFR 28.850 - Main source of electrical power.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... controls; (2) Interior lighting; (3) Steering systems; (4) Communication systems; (5) Navigation equipment and navigation lights; (6) Fire protection or detection equipment; (7) Bilge pumps; and (8) General...

  3. 46 CFR 28.355 - Main source of electrical power.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... auxiliaries and controls; (2) Interior lighting; (3) Steering systems; (4) Communication systems; (5) Navigation equipment and navigation lights; (6) Fire protection or detection equipment; (7) Bilge pumps; or...

  4. 46 CFR 28.850 - Main source of electrical power.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... controls; (2) Interior lighting; (3) Steering systems; (4) Communication systems; (5) Navigation equipment and navigation lights; (6) Fire protection or detection equipment; (7) Bilge pumps; and (8) General...

  5. Quantifying the environmental impacts of artisanal fishing gear on Kenya's coral reef ecosystems.

    PubMed

    Mangi, S C; Roberts, C M

    2006-12-01

    The environmental impacts of artisanal fishing gear on coral reef ecosystems were studied in the multi-gear fishery of southern Kenya to evaluate which types of gear have the greatest impact on coral reef biodiversity. The gear types studied were large and small traps, gill nets, beach seines, hand lines and spear guns. Levels of coral damage, proportion of juvenile fish and discards, size and maturity stage at first capture were quantified and compared amongst the gear types. Results indicate that fishers using beach seines, spears and gill nets cause the most direct physical damage to corals. Spear fishers showed the highest number of contacts to live corals per unit catch followed by fishers using gill nets (12.6+/-1.8 and 5.9+/-2.0 coral contacts per kg fish caught per trip respectively). Apart from discarding 6.5% of their daily catch in the sea, as it was too small, beach seine fishers also landed the highest percentage of juvenile fish (68.4+/-15.7%), a proportion significantly higher (p<0.001) than in any other gear. The size and maturity stage at first capture for 150 of 195 species caught by all gear types was well below the lengths at which they mature. For example, 100% of Lethrinus xanthochilus, 99% of Lethrinus nebulosus and 94% of Lethrinus harak caught were juveniles. Across all gear types, 50.1+/-22.7% of the catch consisted of juvenile fish, indicating serious growth overfishing. Field assessment of levels of coral density showed that fishing grounds where beach seines were still in use had a significantly lower density than where beach seining was not used. This correlation is likely to arise in part because seines cannot be used in the most coral rich areas, and in part because coral loss is a consequence of seine use. On a per gear basis therefore, beach seines had the most impact on coral reef biodiversity. This study emphasizes the need to enforce restrictions on destructive gear and mesh sizes.

  6. Grassland Degradation Alters Soil Carbon Turnover through Depth

    NASA Astrophysics Data System (ADS)

    Creamer, C.; Prober, S. M.; Chappell, A.; Farrell, M.; Baldock, J.

    2015-12-01

    Ecosystem degradation is widespread and changes in aboveground plant communities alter belowground soil processes. In Australia, grassy eucalyptus woodlands dominated by kangaroo grasses (Themeda trianda) were widely cleared during European settlement for agriculture, with only fragments remaining of this now threatened ecosystem. As remnant grassland fragments are used for livestock grazing, Themeda transitions through states of degradation, starting with red grasses (Bothriochloa spp) and then proceeding to less productive, increasingly degraded states dominated by either annual exotic weeds or native wallaby grasses (Rytidosperma spp) and spear grasses (Austrastipa spp). The aim of our experiment was to determine how soil organic matter dynamics (including erosion, root biomass, C storage and turnover) have been altered by the transition from deeply-rooted Themeda grass systems to more shallowly-rooted annual exotic weeds and wallaby/spear grass states. We sampled soils in five depth-based increments (0-5, 5-15, 15-30, 30-60, 60-100 cm) across this ecosystem transition at five sites across New South Wales, Australia. Caseium-137 analysis indicated erosion rates were similar among all ecosystems and were consistent with levels for grasslands in the region. Compared to the remnant Themeda grass systems, the degraded states had lower root biomass, lower carbon stocks and C:N ratios in the coarse fraction (> 50 μm), lower fungal : bacterial ratios, higher available phosphate, higher alkyl : O-alkyl C ratios, and faster mineralization of synthetic root-exudate carbon. All these metrics indicate the surprising finding of more microbially processed OM and faster turnover of newly added C in the degraded sites. Compared to one another, the two degraded sites differed in both C and N turnover, with the exotic weeds having higher dissolved organic N, inorganic N, and coarse fraction N, higher fine fraction C stocks, and greater microbial biomass. These differences likely arise from the greater aboveground productivity of exotic weeds relative to the wallaby and spear grasses. Although microbial C turnover through depth is altered with grassland degradation in both states, the trajectory of the soil organic matter dynamics with degradation is also impacted by plant community dynamics.

  7. Nsls-II Boster

    NASA Astrophysics Data System (ADS)

    Gurov, S. M.; Akimov, A. V.; Akimov, V. E.; Anashin, V. V.; Anchugov, O. V.; Baranov, G. N.; Batrakov, A. M.; Belikov, O. V.; Bekhtenev, E. A.; Blum, E.; Bulatov, A. V.; Burenkov, D. B.; Cheblakov, P. B.; Chernyakin, A. D.; Cheskidov, V. G.; Churkin, I. N.; Davidsavier, M.; Derbenev, A. A.; Erokhin, A. I.; Fliller, R. P.; Fulkerson, M.; Gorchakov, K. M.; Ganetis, G.; Gao, F.; Gurov, D. S.; Hseuh, H.; Hu, Y.; Johanson, M.; Kadyrov, R. A.; Karnaev, S. E.; Karpov, G. V.; Kiselev, V. A.; Kobets, V. V.; Konstantinov, V. M.; Kolmogorov, V. V.; Korepanov, A. A.; Kramer, S.; Krasnov, A. A.; Kremnev, A. A.; Kuper, E. A.; Kuzminykh, V. S.; Levichev, E. B.; Li, Y.; Long, J. De; Makeev, A. V.; Mamkin, V. R.; Medvedko, A. S.; Meshkov, O. I.; Nefedov, N. B.; Neyfeld, V. V.; Okunev, I. N.; Ozaki, S.; Padrazo, D.; Petrov, V. V.; Petrichenkov, M. V.; Philipchenko, A. V.; Polyansky, A. V.; Pureskin, D. N.; Rakhimov, A. R.; Rose, J.; Ruvinskiy, S. I.; Rybitskaya, T. V.; Sazonov, N. V.; Schegolev, L. M.; Semenov, A. M.; Semenov, E. P.; Senkov, D. V.; Serdakov, L. E.; Serednyakov, S. S.; Shaftan, T. V.; Sharma, S.; Shichkov, D. S.; Shiyankov, S. V.; Shvedov, D. A.; Simonov, E. A.; Singh, O.; Sinyatkin, S. V.; Smaluk, V. V.; Sukhanov, A. V.; Tian, Y.; Tsukanova, L. A.; Vakhrushev, R. V.; Vobly, P. D.; Utkin, A. V.; Wang, G.; Wahl, W.; Willeke, F.; Yaminov, K. R.; Yong, H.; Zhuravlev, A.; Zuhoski, P.

    The National Synchrotron Light Source II is a third generation light source, which was constructed at Brookhaven National Laboratory. This project includes a highly-optimized 3 GeV electron storage ring, linac preinjector, and full-energy synchrotron injector. Budker Institute of Nuclear Physics built and delivered the booster for NSLS-II. The commissioning of the booster was successfully completed. This paper reviews fulfilled work by participants.

  8. Hybridization with a twist: Hidden (hastatic) order in URu2Si2

    NASA Astrophysics Data System (ADS)

    Flint, Rebecca

    The hidden order developing below 17.5K in the heavy fermion material URu2Si2 has eluded identification for over thirty years. A number of recent experiments have shed new light on the nature of this phase. In particular, de Haas-van Alphen measurements indicate nearly perfectly Ising quasiparticles deep in the hidden order phase, and recent nonlinear susceptibility measurements show that this strong Ising anisotropy persists up to and above the hidden order transition itself. Along with other features, this Ising anisotropy implies that the conduction electrons hybridize with a local Ising moment - a 5f2 state of the uranium atom with integer spin. As the hybridization mixes states of integer and half-integer spin, it is itself a spinor and this ``hastatic'' (hasta: [Latin] spear) order parameter therefore breaks both time-reversal and double time-reversal symmetries. A microscopic theory of hastatic order naturally unites a number of disparate experimental results from the large entropy of condensation to the spin rotational symmetry breaking seen in torque magnetometry, and provides a number of experimental predictions. Moreover, this new spinorial order parameter provides a window into a number of new heavy fermion phases.

  9. OLED lighting devices having multi element light extraction and luminescence conversion layer

    DOEpatents

    Krummacher, Benjamin Claus; Antoniadis, Homer

    2010-11-16

    An apparatus such as a light source has a multi element light extraction and luminescence conversion layer disposed over a transparent layer of the light source and on the exterior of said light source. The multi-element light extraction and luminescence conversion layer includes a plurality of light extraction elements and a plurality of luminescence conversion elements. The light extraction elements diffuses the light from the light source while luminescence conversion elements absorbs a first spectrum of light from said light source and emits a second spectrum of light.

  10. Multi-wavelength mid-IR light source for gas sensing

    NASA Astrophysics Data System (ADS)

    Karioja, Pentti; Alajoki, Teemu; Cherchi, Matteo; Ollila, Jyrki; Harjanne, Mikko; Heinilehto, Noora; Suomalainen, Soile; Viheriälä, Jukka; Zia, Nouman; Guina, Mircea; Buczyński, Ryszard; Kasztelanic, Rafał; Kujawa, Ireneusz; Salo, Tomi; Virtanen, Sami; Kluczyński, Paweł; Sagberg, Hâkon; Ratajczyk, Marcin; Kalinowski, Przemyslaw

    2017-02-01

    Cost effective multi-wavelength light sources are key enablers for wide-scale penetration of gas sensors at Mid-IR wavelength range. Utilizing novel Mid-IR Si-based photonic integrated circuits (PICs) filter and wide-band Mid-IR Super Luminescent Light Emitting Diodes (SLEDs), we show the concept of a light source that covers 2.5…3.5 μm wavelength range with a resolution of <1nm. The spectral bands are switchable and tunable and they can be modulated. The source allows for the fabrication of an affordable multi-band gas sensor with good selectivity and sensitivity. The unit price can be lowered in high volumes by utilizing tailored molded IR lens technology and automated packaging and assembling technologies. The status of the development of the key components of the light source are reported. The PIC is based on the use of micron-scale SOI technology, SLED is based on AlGaInAsSb materials and the lenses are tailored heavy metal oxide glasses fabricated by the use of hot-embossing. The packaging concept utilizing automated assembly tools is depicted. In safety and security applications, the Mid-IR wavelength range covered by the novel light source allows for detecting several harmful gas components with a single sensor. At the moment, affordable sources are not available. The market impact is expected to be disruptive, since the devices currently in the market are either complicated, expensive and heavy instruments, or the applied measurement principles are inadequate in terms of stability and selectivity.

  11. Speckle Free, Low Coherency, High Brightness, and High Pulse Speed Infrared Collimated Light Sources for Mid-IR Target Designator and Hyperspectral Imaging

    DTIC Science & Technology

    2007-10-31

    designator and hyperspectral imaging 6. AUfHOR(S) Yee-LoyLam 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION DenseLight...DenseLight Semiconductors CONTENTS 1. Introduction 3 1.1 Overview of Project 3 1.2 Organization of Project 4 1.3 Target...Performance 4 2. SLED Chip Design and Fabrication Development 5 2.1 Organization of Design Stages 5 2.2 SLED Chip Design 6 2.3

  12. Circadian Behavioral Study: LED vs Cool White Fluorescent - 0.1, 1, 10, 40, 80 lux. Part 2

    NASA Technical Reports Server (NTRS)

    Holley, Daniel C.; Syrkin, N.; Mele, G.

    2000-01-01

    Currently, the light source most commonly used in animal habitat lighting is cool white fluorescent (CWF) light. It was the objective of this study to evaluate a novel LED light source for use in animal habitat lighting by comparing its effectiveness to CWF light in producing and maintaining a normal circadian entrainment. The LED and CWF lights had similar spectral power distributions. Sprague-Dawley rats (175-350 g) were kept individually in metabolic cages, under a strict lighting control: 4 days of acclimation at 12:12 LD, 14 days of 12:12 LD, 14 days of 24:0 LD (free-run), and finally 12:12 LD. Food and water were provided ad libitum. Three behavioral parameters were monitored continuously: gross locomotor activity, drinking, and feeding. Combined mean free run periods (tau) were (mean +/- SEM): 24.6 +/- 0.1 and 24.7 +/- 0.2 at 0.1 lux, 25.5 +/- 0.1 and 25.7 +/- 0.1 at 1.0 lux, 25.3 +/- 0.2 and 25.4 +/- 0.2 at 10 lux, 25.8 +/- 0.1 and 25.9 +/- 0.1 at 40 lux, and 25.9 +/- 0.1 and 25.9 +/- 0.1 at 80 lux, CWF and LED respectively. ANOVA found a significant effect (p < 0.05) due to light level, but no difference in tau between rats exposed to constant CWF light and rats exposed to constant LED light. This study has shown that LED light can produce the same entrainment pattern as a conventional CWT light at similar intensities (0.1, 1, 10, 40, and 80 lux). LED light sources may be a suitable replacement for conventional light sources used in animal habitat lighting while providing many mechanical and economical advantages.

  13. Broadband white light emission from Ce:AlN ceramics: High thermal conductivity down-converters for LED and laser-driven solid state lighting

    NASA Astrophysics Data System (ADS)

    Wieg, A. T.; Penilla, E. H.; Hardin, C. L.; Kodera, Y.; Garay, J. E.

    2016-12-01

    We introduce high thermal conductivity aluminum nitride (AlN) as a transparent ceramic host for Ce3+, a well-known active ion dopant. We show that the Ce:AlN ceramics have overlapping photoluminescent (PL) emission peaks that cover almost the entire visible range resulting in a white appearance under 375 nm excitation without the need for color mixing. The PL is due to a combination of intrinsic AlN defect complexes and Ce3+ electronic transitions. Importantly, the peak intensities can be tuned by varying the Ce concentration and processing parameters, causing different shades of white light without the need for multiple phosphors or light sources. The Commission Internationale de l'Eclairage coordinates calculated from the measured spectra confirm white light emission. In addition, we demonstrate the viability of laser driven white light emission by coupling the Ce:AlN to a readily available frequency tripled Nd-YAG laser emitting at 355 nm. The high thermal conductivity of these ceramic down-converters holds significant promise for producing higher power white light sources than those available today.

  14. Measuring joint cartilage thickness using reflectance spectroscopy non-invasively and in real-time

    NASA Astrophysics Data System (ADS)

    Canpolat, Murat; Denkceken, Tuba; Karagol, Cosar; Aydin, Ahmet T.

    2011-03-01

    Joint cartilage thickness has been estimated using spatially resolved steady-state reflectance spectroscopy noninvasively and in-real time. The system consists of a miniature UV-VIS spectrometer, a halogen tungsten light source, and an optical fiber probe with six 400 um diameter fibers. The first fiber was used to deliver the light to the cartilage and the other five were used to detect back-reflected diffused light. Distances from the detector fibers to the source fiber were 0.8 mm, 1.6 mm, 2.4 mm, 3.2 mm and 4 mm. Spectra of back-reflected diffused light were taken on 40 bovine patella cartilages. The samples were grouped into four; the first group was the control group with undamaged cartilages, in the 2nd, 3rd and 4th groups cartilage thickness was reduced approximately 25%, 50% and 100%, respectively. A correlation between cartilage thicknesses and hemoglobin absorption of light in the wavelength range of 500 nm- 600 nm for source-detector pairs was found. The proposed system with an optical fiber probe less than 4 mm in diameter has the potential for cartilage thickness assessment through an arthroscopy channel in real-time without damaging the cartilage.

  15. Device structure for OLED light device having multi element light extraction and luminescence conversion layer

    DOEpatents

    Antoniadis,; Homer, Krummacher [Mountain View, CA; Claus, Benjamin [Regensburg, DE

    2008-01-22

    An apparatus such as a light source has a multi-element light extraction and luminescence conversion layer disposed over a transparent layer of the light source and on the exterior of said light source. The multi-element light extraction and luminescence conversion layer includes a plurality of light extraction elements and a plurality of luminescence conversion elements. The light extraction elements diffuses the light from the light source while luminescence conversion elements absorbs a first spectrum of light from said light source and emits a second spectrum of light.

  16. Design of a Programmable Star Tracker-Based Reference System for a Simulated Spacecraft

    DTIC Science & Technology

    2014-03-27

    This reduces the overall light intensity hitting the sensor, as indicated by the darker color. However, the red and green circles are also forming...may be beneficial on SimSat since we can control the light output depending on the source chosen. It is possible to sacrifice some star light intensity ...could be done to improve accuracy based on what could be controlled and changed easily. 3.2.3.1 Focal Length. The optics portion of the light collection

  17. Kimzeyite garnet phosphors

    DOEpatents

    Lyons, Robert Joseph

    2013-05-14

    A phosphor of formula I is included in a phosphor composition in a lighting apparatus capable of emitting white light, Ca.sub.3-x-zSr.sub.xCe.sub.zM.sup.1.sub.2M.sup.2AlSiO.sub.12 (I) wherein M.sup.1 is Hf, Zr, or a combination thereof; M.sup.2 is Al, or a combination of Al and Ga; z<3-x; and 0.2>x.gtoreq.0. The lighting apparatus includes a semiconductor light source in addition to the phosphor composition.

  18. Terahertz Physics

    NASA Astrophysics Data System (ADS)

    Lewis, R. A.

    2013-01-01

    1. Introduction; Part I. Basics: 2. Oscillations; 3. Combining oscillations; 4. Light; 5. Matter; 6. Interaction of light and matter; Part II. Components: 7. Sources; 8. Optics; 9. Detectors; Part III. Applications: 10. Spectroscopy; 11. Imaging; Glossary; Appendices; Index.

  19. A quality assurance program for clinical PDT

    NASA Astrophysics Data System (ADS)

    Dimofte, Andreea; Finlay, Jarod; Ong, Yi Hong; Zhu, Timothy C.

    2018-02-01

    Successful outcome of Photodynamic therapy (PDT) depends on accurate delivery of prescribed light dose. A quality assurance program is necessary to ensure that light dosimetry is correctly measured. We have instituted a QA program that include examination of long term calibration uncertainty of isotropic detectors for light fluence rate, power meter head intercomparison for laser power, stability of the light-emitting diode (LED) light source integrating sphere as a light fluence standard, laser output and calibration of in-vivo reflective fluorescence and absorption spectrometers. We examined the long term calibration uncertainty of isotropic detector sensitivity, defined as fluence rate per voltage. We calibrate the detector using the known calibrated light fluence rate of the LED light source built into an internally baffled 4" integrating sphere. LED light sources were examined using a 1mm diameter isotropic detector calibrated in a collimated beam. Wavelengths varying from 632nm to 690nm were used. The internal LED method gives an overall calibration accuracy of +/- 4%. Intercomparison among power meters was performed to determine the consistency of laser power and light fluence rate measured among different power meters. Power and fluence readings were measured and compared among detectors. A comparison of power and fluence reading among several power heads shows long term consistency for power and light fluence rate calibration to within 3% regardless of wavelength. The standard LED light source is used to calibrate the transmission difference between different channels for the diffuse reflective absorption and fluorescence contact probe as well as isotropic detectors used in PDT dose dosimeter.

  20. III-nitride nanowire LEDs and diode lasers: monolithic light sources on (001) Si emitting in the 600-1300nm range

    NASA Astrophysics Data System (ADS)

    Bhattacharya, P.; Hazari, A.; Jahangir, S.

    2018-02-01

    GaN-based nanowire heterostructure arrays epitaxially grown on (001)Si substrates have unique properties and present the potential to realize useful devices. The active light-emitting region in the nanowire heterostructures are usually InGaN disks, whose composition can be varied to tune the emission wavelength. We have demonstrated light emitting diodes and edgeemitting diode lasers with power outputs 10mW with emission in the 600-1300nm wavelength range. These light sources are therefore useful for a variety of applications, including silicon photonics. Molecular beam epitaxial growth of the nanowire heterostructure arrays on (001)Si substrates and the characteristics of 1.3μm nanowire array edge emitting lasers, guided wave photodiodes and a monolithic photonic integrated circuit designed for 1.3μm operation are described.

  1. OPO-based compact laser projection display

    NASA Astrophysics Data System (ADS)

    Lee, Dicky; Moulton, Peter F.; Bergstedt, Robert; Flint, Graham W.

    2001-09-01

    In this paper we discuss our red, green, and blue (RGB) optical parametric oscillator (OPO) based laser projection display. The complete project display consists of two subsystems, the RGB-OPO laser head and the light modulation unit. The RGB lights from rack-mounted laser head are fibers coupled to the projection unit for independent placement. The light source consists of a diode-pumped pump laser and a LBO-based OPO. Based on our Nd:YLF gain module design, the pump laser is frequency doubled to serve as the pump source for the OPO. The unconverted pump power is recycled as the green light for projection. The singly resonant, non- critically phase-matched (NCPM) OPO has, to date, generated 13 W of 898-nm signal power and an estimated 9.3 W of intra- cavity idler power at 1256 nm. With approximately 76% of pump depletion, the power of the residual green light for projection is about 5.8 W. We have extra-cavity doubled the signal to produce approximately 3.5 W of 449-nm blue light and intra-cavity doubled the idler to produce approximately 6 W of 628-nm red light. The OPO-based RGB source generates about 4000 lumens of D65-balanced white light. The overall electrical power on a commercially available JVC's three- panel D-ILA (reflective LCD) projector with the arc-lamp removed and extensive modifications. The projector has a native resolution of 1365 x 1024 and the expected on screen lumens from our laser display is about 1200 lumens.

  2. Low-pressure Structural Modification of Aluminum Hydride

    DTIC Science & Technology

    2011-02-01

    Acknowledgments Use of the National Synchrotron Light Source (NSLS), Brookhaven National Laboratory ( BNL ) was supported by the U.S. Department of Energy...National Synchrotron Light Source (NSLS) of Brookhaven National Laboratory ( BNL ). The spectral resolution of ±4 cm–1 was used for all IR measurements...12 List of Symbols, Abbreviations, and Acronyms Al aluminum AlH3 aluminum hydride BNL Brookhaven National Laboratory EOS equation of

  3. Backscatter absorption gas imaging systems and light sources therefore

    DOEpatents

    Kulp, Thomas Jan [Livermore, CA; Kliner, Dahv A. V. [San Ramon, CA; Sommers, Ricky [Oakley, CA; Goers, Uta-Barbara [Campbell, NY; Armstrong, Karla M [Livermore, CA

    2006-12-19

    The location of gases that are not visible to the unaided human eye can be determined using tuned light sources that spectroscopically probe the gases and cameras that can provide images corresponding to the absorption of the gases. The present invention is a light source for a backscatter absorption gas imaging (BAGI) system, and a light source incorporating the light source, that can be used to remotely detect and produce images of "invisible" gases. The inventive light source has a light producing element, an optical amplifier, and an optical parametric oscillator to generate wavelength tunable light in the IR. By using a multi-mode light source and an amplifier that operates using 915 nm pump sources, the power consumption of the light source is reduced to a level that can be operated by batteries for long periods of time. In addition, the light source is tunable over the absorption bands of many hydrocarbons, making it useful for detecting hazardous gases.

  4. Assessment of light extinction at a European polluted urban area during wintertime: Impact of PM1 composition and sources.

    PubMed

    Vecchi, R; Bernardoni, V; Valentini, S; Piazzalunga, A; Fermo, P; Valli, G

    2018-02-01

    In this paper, results from receptor modelling performed on a well-characterised PM 1 dataset were combined to chemical light extinction data (b ext ) with the aim of assessing the impact of different PM 1 components and sources on light extinction and visibility at a European polluted urban area. It is noteworthy that, at the state of the art, there are still very few papers estimating the impact of different emission sources on light extinction as we present here, although being among the major environmental challenges at many polluted areas. Following the concept of the well-known IMPROVE algorithm, here a tailored site-specific approach (recently developed by our group) was applied to assess chemical light extinction due to PM 1 components and major sources. PM 1 samples collected separately during daytime and nighttime at the urban area of Milan (Italy) were chemically characterised for elements, major ions, elemental and organic carbon, and levoglucosan. Chemical light extinction was estimated and results showed that at the investigated urban site it is heavily impacted by ammonium nitrate and organic matter. Receptor modelling (i.e. Positive Matrix Factorization, EPA-PMF 5.0) was effective to obtain source apportionment; the most reliable solution was found with 7 factors which were tentatively assigned to nitrates, sulphates, wood burning, traffic, industry, fine dust, and a Pb-rich source. The apportionment of aerosol light extinction (b ext,aer ) according to resolved sources showed that considering all samples together nitrate contributed at most (on average 41.6%), followed by sulphate, traffic, and wood burning accounting for 18.3%, 17.8% and 12.4%, respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Driver circuit for solid state light sources

    DOEpatents

    Palmer, Fred; Denvir, Kerry; Allen, Steven

    2016-02-16

    A driver circuit for a light source including one or more solid state light sources, a luminaire including the same, and a method of so driving the solid state light sources are provided. The driver circuit includes a rectifier circuit that receives an alternating current (AC) input voltage and provides a rectified AC voltage. The driver circuit also includes a switching converter circuit coupled to the light source. The switching converter circuit provides a direct current (DC) output to the light source in response to the rectified AC voltage. The driver circuit also includes a mixing circuit, coupled to the light source, to switch current through at least one solid state light source of the light source in response to each of a plurality of consecutive half-waves of the rectified AC voltage.

  6. The Olive Branch and the Spear: Merging Diplomatic Actions and Special Operations in Conflict Prevention

    DTIC Science & Technology

    2013-06-13

    The survey was reviewed and approved by the CGSC Human Protections Administrator under the number #13-03-055. This survey targeted an audience of ...merging the human resources from both organizations for “high reward low cost” operations. At the operational level, an overall review of the ...indirect approaches, in order to successfully take up the conflict prevention challenge. Assessing the robustness of an

  7. Total Hadron Cross Section, New Particles, and Muon Electron Events in e{sup +}e{sup -} Annihilation at SPEAR

    DOE R&D Accomplishments Database

    Richter, B.

    1976-01-01

    The review of total hadron electroproduction cross sections, the new states, and the muon--electron events includes large amount of information on hadron structure, nine states with width ranging from 10's of keV to many MeV, the principal decay modes and quantum numbers of some of the states, and limits on charm particle production. 13 references. (JFP)

  8. Field experiments using SPEAR: a speech control system for UGVs

    NASA Astrophysics Data System (ADS)

    Chhatpar, Siddharth R.; Blanco, Chris; Czerniak, Jeffrey; Hoffman, Orin; Juneja, Amit; Pruthi, Tarun; Liu, Dongqing; Karlsen, Robert; Brown, Jonathan

    2009-05-01

    This paper reports on a Field Experiment carried out by the Human Research and Engineering Directorate at Ft. Benning to evaluate the efficacy of using speech to control an Unmanned Ground Vehicle (UGV) concurrently with a handcontroller. The SPEAR system, developed by Think-A-Move, provides speech-control of UGVs. The system picks up user-speech in the ear canal with an in-ear microphone. This property allows it to work efficiently in high-noise environments, where traditional speech systems, employing external microphones, fail. It has been integrated with an iRobot PackBot 510 with EOD kit. The integrated system allows the hand-controller to be supplemented with speech for concurrent control. At Ft. Benning, the integrated system was tested by soldiers from the Officer Candidate School. The Experiment had dual focus: 1) Quantitative measurement of the time taken to complete each station and the cognitive load on users; 2) Qualitative evaluation of ease-of-use and ergonomics through soldier-feedback. Also of significant benefit to Think-A-Move was soldier-feedback on the speech-command vocabulary employed: What spoken commands are intuitive, and how the commands should be executed, e.g., limited-motion vs. unlimited-motion commands. Overall results from the Experiment are reported in the paper.

  9. "NEW MEMBRANE" FORMATION IN AMOEBA PROTEUS UPON INJURY OF INDIVIDUAL CELLS

    PubMed Central

    Szubinska, Barbara

    1971-01-01

    Changes in the plasma membrane complex following the injury of single cells of Amoeba proteus were examined with the electron microscope. Two types of injury were employed in this study; cells were either pinched ("cut") in half or speared with a glass microneedle, and quickly fixed. Speared cells, when fixed in the presence of the ruthenium violet (a derivative of ruthenium red), revealed the presence of an extra trilaminar structure outside of each cell. This structure, called the "new membrane," was separated from the plasma membrane complex by a distance of less than a micron. The trilaminar structure of the new membrane strikingly resembled the image of the plasma membrane in all cells examined, except for its increased width (30%). This new membrane appeared nearly to surround the injured amebae. Attempts were made to demonstrate the possible origin of the new membrane, its reality, and its sensitivity to calcium. Also, some evidence is shown concerning the role of the small dense droplets (100–1200 A in diameter) normally present in the cytoplasm of amebae. Their frequent contact with the plasma membrane of the cell as the result of injury is interpreted as indicating their involvement in the formation and expansion of the plasma membrane. PMID:4103955

  10. Effects of modification of the polar ionosphere with high-power short-wave extraordinary-mode HF waves produced by the spear heating facility

    NASA Astrophysics Data System (ADS)

    Borisova, T. D.; Blagoveshchenskaya, N. F.; S. Kalishin, A.; Oksavik, K.; Baddelley, L.; K. Yeoman, T.

    2012-06-01

    We present the results of modifying the F2 layer of the polar ionosphere experimentally with highpower HF extraordinary-mode waves. The experiments were performed in October 2010 using the short-wave SPEAR heating facility (Longyearbyen, Spitsbergen). To diagnose the effects of high-power HF waves by the aspect-scattering method in a network of diagnostic paths, we used the short-wave Doppler radar CUTLASS (Hankasalmi, Finland) and the incoherent scatter radar ESR (Longyearbyen, Spitsbergen). Excitation of small-scale artificial ionospheric irregularities was revealed, which were responsible for the aspect and backward scattering of the diagnostic signals. The measurements performed by the ESR incoherent scatter radar simultaneously with the heating demonstrated changes in the parameters of the ionospheric plasma, specifically, an increase in the electron density by 10-25 % and an increase in the electron temperature by 10-30 % at the altitudes of the F2 layer, as well as formation of sporadic ionization at altitudes of 140-180 km (below the F2 layer maximum). To explain the effects of ionosphere heating with HF extraordinary-mode waves, we propose a hypothesis of transformation of extraordinary electromagnetic waves to ordinary in the anisotropic, smoothly nonuniform ionosphere.

  11. Implications of the SPEAR FUV Maps on Our Understanding of the ISM

    NASA Astrophysics Data System (ADS)

    Korpela, Eric J.; Sirk, Martin; Edelstein, Jerry; Seon, Kwangil; Min, Kyoung-Wook; Han, Wonyong

    2009-08-01

    The distribution of a low-density transition temperature (104.5-105.5 K) gas in the interstellar medium conveys the character and evolution of diffuse matter in the Galaxy. This difficult to observe component of the ISM emits mainly in the far-ultraviolet (FUV) (912-1800 A˚) band. We describe spectral maps of FUV emission lines from the highly ionized species CIV and OVI likely to be the dominant cooling mechanisms of transition temperature gas in the ISM. The maps were obtained using an orbital spectrometer, SPEAR, that was launched in 2003 and has observed the FUV sky with a spectral resolution of ~550 and an angular resolution of 10'. We compare distribution of flux in these maps with three basic models of the distribution of transition temperature gas. We find that the median distribution of CIV and OVI emission is consistent with the spatial distribution and line ratios expected from a McKee-Ostriker (MO) type model of evaporative interfaces. However, the intensities are a factor of three higher than would be expected at the MO preferred parameters. Some high intensity regions are clearly associated with supernova remnants and superbubble structures. Others may indicate regions where gas is cooling through the transition temperature.

  12. Design of TIR collimating lens for ordinary differential equation of extended light source

    NASA Astrophysics Data System (ADS)

    Zhan, Qianjing; Liu, Xiaoqin; Hou, Zaihong; Wu, Yi

    2017-10-01

    The source of LED has been widely used in our daily life. The intensity angle distribution of single LED is lambert distribution, which does not satisfy the requirement of people. Therefore, we need to distribute light and change the LED's intensity angle distribution. The most commonly method to change its intensity angle distribution is the free surface. Generally, using ordinary differential equations to calculate free surface can only be applied in a point source, but it will lead to a big error for the expand light. This paper proposes a LED collimating lens based on the ordinary differential equation, combined with the LED's light distribution curve, and adopt the method of calculating the center gravity of the extended light to get the normal vector. According to the law of Snell, the ordinary differential equations are constructed. Using the runge-kutta method for solution of ordinary differential equation solution, the curve point coordinates are gotten. Meanwhile, the edge point data of lens are imported into the optical simulation software TracePro. Based on 1mm×1mm single lambert body for light conditions, The degrees of collimating light can be close to +/-3. Furthermore, the energy utilization rate is higher than 85%. In this paper, the point light source is used to calculate partial differential equation method and compared with the simulation of the lens, which improve the effect of 1 degree of collimation.

  13. Choice of Illumination System & Fluorophore for Multiplex Immunofluorescence on FFPE Tissue Sections

    PubMed Central

    Kishen, Ria E. B.; Kluth, David C.; Bellamy, Christopher O. C.

    2016-01-01

    The recent availability of novel dyes and alternative light sources to facilitate complex tissue immunofluorescence studies such as multiplex labelling has not been matched by reports critically evaluating the considerations and relative benefits of these new tools, particularly in combination. Product information is often limited to wavelengths used for older fluorophores (FITC, TRITC & corresponding Alexa dyes family). Consequently, novel agents such as Quantum dots are not widely appreciated or used, despite highly favourable properties including extremely bright emission, stability and potentially reduced tissue autofluorescence at the excitation wavelength. Using spectral analysis, we report here a detailed critical appraisal and comparative evaluation of different light sources and fluorophores in multiplex immunofluorescence of clinical biopsy sections. The comparison includes mercury light, metal halide and 3 different LED-based systems, using 7 Qdots (525, 565, 585, 605, 625, 705), Cy3 and Cy5. We discuss the considerations relevant to achieving the best combination of light source and fluorophore for accurate multiplex fluorescence quantitation. We highlight practical limitations and confounders to quantitation with filter-based approaches. PMID:27632367

  14. Position Index for the Matrix Light Source

    NASA Astrophysics Data System (ADS)

    Takahashi, Hiroshi; Kobayashi, Yoshinori; Onda, Shou; Irikura, Takashi

    It is expected that in the future white LEDs will be widely used in practical applications including replacing conventional lighting in offices and homes. The white LED light source of matrix arrangement is also considered in it. On the other hand, although now the unified glare rating (UGR) is widely used for evaluation of the discomfort glare of the interior lighting, UGR is a thing for a uniform light source, and its application to the matrix light sources that have non-uniform luminance has not been considered. The aim of this study is to clarify the position index which is one of element of UGR for the matrix light source. In this case, to apply the position index for a matrix light source to UGR, the concept of the revised position index is invented. As the preliminary experiment, method for measuring the position index was conducted, and as the experiment, position index for the matrix light source was conducted and compared with the uniform light source. The results of the experiments show that the position index is decided by the relative angle between line of sight and light source. It is also found that the matrix light source have larger position index than uniform light source. Furthermore, it is shown that the discomfort glare caused by a matrix light source can be evaluated by applying the revised position index to the UGR.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alekseev, A E; Potapov, V T; Gorshkov, B G

    We report the results of studying statistical properties of the intensity of partially polarised coherent light backscattered by a single mode optical fibre. An expression is derived for the deviation of the backscattered light intensity depending on the scattering region length, the degree of the light source coherence and the degree of scattered light polarisation. It is shown that the backscattered light in a fibre scattered-light interferometer is partially polarised with the polarisation degree P = 1/3 in the case of external perturbations of the interferometer fibre. (scattering of light)

  16. Kerosene lighting contributes to household air pollution in rural Uganda.

    PubMed

    Muyanja, D; Allen, J G; Vallarino, J; Valeri, L; Kakuhikire, B; Bangsberg, D R; Christiani, D C; Tsai, A C; Lai, P S

    2017-09-01

    The literature on the contribution of kerosene lighting to indoor air particulate concentrations is sparse. In rural Uganda, kitchens are almost universally located outside the main home, and kerosene is often used for lighting. In this study, we obtained longitudinal measures of particulate matter 2.5 microns or smaller in size (PM 2.5 ) from living rooms and kitchens of 88 households in rural Uganda. Linear mixed-effects models with a random intercept for household were used to test the hypotheses that primary reported lighting source and kitchen location (indoor vs outdoor) are associated with PM 2.5 levels. During initial testing, households reported using the following sources of lighting: open-wick kerosene (19.3%), hurricane kerosene (45.5%), battery-powered (33.0%), and solar (1.1%) lamps. During follow-up testing, these proportions changed to 29.5%, 35.2%, 18.2%, and 9.1%, respectively. Average ambient, living room, and kitchen PM 2.5 levels were 20.2, 35.2, and 270.0 μg/m 3 . Living rooms using open-wick kerosene lamps had the highest PM 2.5 levels (55.3 μg/m 3 ) compared to those using solar lighting (19.4 μg/m 3 ; open wick vs solar, P=.01); 27.6% of homes using open-wick kerosene lamps met World Health Organization indoor air quality standards compared to 75.0% in homes using solar lighting. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Gamma-Ray Light Curves And Variability Of Bright Fermi -Detected Blazars

    DOE PAGES

    Abdo, A. A.

    2010-09-22

    This paper presents light curves as well as the first systematic characterization of variability of the 106 objects in the high-confidence Fermi Large Area Telescope Bright AGN Sample (LBAS). Weekly light curves of this sample, obtained during the first 11 months of the Fermi survey (2008 August 4-2009 July 4), are tested for variability and their properties are quantified through autocorrelation function and structure function analysis. For the brightest sources, 3 or 4 day binned light curves are extracted in order to determine power density spectra (PDSs) and to fit the temporal structure of major flares. More than 50% ofmore » the sources are found to be variable with high significance, where high states do not exceed 1/4 of the total observation range. Variation amplitudes are larger for flat spectrum radio quasars and low/intermediate synchrotron frequency peaked BL Lac objects. Autocorrelation timescales derived from weekly light curves vary from four to a dozen of weeks. Variable sources of the sample have weekly and 3-4 day bin light curves that can be described by 1/f α PDS, and show two kinds of gamma-ray variability: (1) rather constant baseline with sporadic flaring activity characterized by flatter PDS slopes resembling flickering and red noise with occasional intermittence and (2)—measured for a few blazars showing strong activity—complex and structured temporal profiles characterized by long-term memory and steeper PDS slopes, reflecting a random walk underlying mechanism. The average slope of the PDS of the brightest 22 FSRQs and of the 6 brightest BL Lacs is 1.5 and 1.7, respectively. The study of temporal profiles of well-resolved flares observed in the 10 brightest LBAS sources shows that they generally have symmetric profiles and that their total duration vary between 10 and 100 days. Results presented here can assist in source class recognition for unidentified sources and can serve as reference for more detailed analysis of the brightest gamma-ray blazars.« less

  18. LED-based endoscopic light source for spectral imaging

    NASA Astrophysics Data System (ADS)

    Browning, Craig M.; Mayes, Samuel; Favreau, Peter; Rich, Thomas C.; Leavesley, Silas J.

    2016-03-01

    Colorectal cancer is the United States 3rd leading cancer in death rates.1 The current screening for colorectal cancer is an endoscopic procedure using white light endoscopy (WLE). There are multiple new methods testing to replace WLE, for example narrow band imaging and autofluorescence imaging.2 However, these methods do not meet the need for a higher specificity or sensitivity. The goal for this project is to modify the presently used endoscope light source to house 16 narrow wavelength LEDs for spectral imaging in real time while increasing sensitivity and specificity. The process to do such was to take an Olympus CLK-4 light source, replace the light and electronics with 16 LEDs and new circuitry. This allows control of the power and intensity of the LEDs. This required a larger enclosure to house a bracket system for the solid light guide (lightpipe), three new circuit boards, a power source and National Instruments hardware/software for computer control. The results were a successfully designed retrofit with all the new features. The LED testing resulted in the ability to control each wavelength's intensity. The measured intensity over the voltage range will provide the information needed to couple the camera for imaging. Overall the project was successful; the modifications to the light source added the controllable LEDs. This brings the research one step closer to the main goal of spectral imaging for early detection of colorectal cancer. Future goals will be to connect the camera and test the imaging process.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jozsef, G

    Purpose: To build a test device for HDR afterloaders capable of checking source positions, times at positions and estimate the activity of the source. Methods: A catheter is taped on a plastic scintillation sheet. When a source travels through the catheter, the scintillator sheet lights up around the source. The sheet is monitored with a video camera, and records the movement of the light spot. The center of the spot on each image on the video provides the source location, and the time stamps of the images can provide the dwell time the source spend in each location. Finally, themore » brightness of the light spot is related to the activity of the source. A code was developed for noise removal, calibrate the scale of the image to centimeters, eliminate the distortion caused by the oblique view angle, identifying the boundaries of the light spot, transforming the image into binary and detect and calculate the source motion, positions and times. The images are much less noisy if the camera is shielded. That requires that the light spot is monitored in a mirror, rather than directly. The whole assembly is covered from external light and has a size of approximately 17×35×25cm (H×L×W) Results: A cheap camera in BW mode proved to be sufficient with a plastic scintillator sheet. The best images were resulted by a 3mm thick sheet with ZnS:Ag surface coating. The shielding of the camera decreased the noise, but could not eliminate it. A test run even in noisy condition resulted in approximately 1 mm and 1 sec difference from the planned positions and dwell times. Activity tests are in progress. Conclusion: The proposed method is feasible. It might simplify the monthly QA process of HDR Brachytherapy units.« less

  20. Image Size Scalable Full-parallax Coloured Three-dimensional Video by Electronic Holography

    NASA Astrophysics Data System (ADS)

    Sasaki, Hisayuki; Yamamoto, Kenji; Ichihashi, Yasuyuki; Senoh, Takanori

    2014-02-01

    In electronic holography, various methods have been considered for using multiple spatial light modulators (SLM) to increase the image size. In a previous work, we used a monochrome light source for a method that located an optical system containing lens arrays and other components in front of multiple SLMs. This paper proposes a colourization technique for that system based on time division multiplexing using laser light sources of three colours (red, green, and blue). The experimental device we constructed was able to perform video playback (20 fps) in colour of full parallax holographic three-dimensional (3D) images with an image size of 63 mm and a viewing-zone angle of 5.6 degrees without losing any part of the 3D image.

  1. Stage 2 Report for Reformulation Phase I General Design Memorandum, Cleveland Harbor, Ohio. Volume II. Appendices. Revision.

    DTIC Science & Technology

    1983-02-01

    Harbor Lighthouse Pointe Betsie Light Station Pennsylvania Port Sanilac Light Station Presque Isle Light Station Presque Isle Light Rock of Ages Light...Marquette, MI : 0.6 : 0.4 0.1 0 : 0 : 0 : 0 : : 0 : 0 : - Presque Isle , MI: 2.4 1.4 1.4 1.3 : 1.4 1.5 1.0 : 0.9 : 0.4 1.3 8.6 Silver Bay, MN 5.0 : 4.1...conditions. The long distance sourcing patterns of Outer Harbor iron ore (Silver Bay, Duluth-Superior, Escanaba, Presque Isle ) also favors the use of

  2. Retinal endoilluminator toxicity of xenon and light-emitting diode (LED) light source: rabbit model.

    PubMed

    Aydin, Bahri; Dinç, Erdem; Yilmaz, S Necat; Altiparmak, U Emrah; Yülek, Fatma; Ertekin, Sevda; Yilmaz, Mustafa; Yakın, Mehmet

    2014-09-01

    This study evaluates retinal toxicity due to endoillumination with the light-emitting diode (LED) light source in comparison to endoillumination with xenon light source. Twenty-five eyes of 14 New Zealand pigmented rabbits were used in the study. The LED light (Omesis Medical Systems, Turkey) group was composed of 7 right eyes, while the other 7 right eyes constituted the xenon group (420 nm filter, 357mW/cm(2)) (Bright Star; DORC, Zuidland, Netherlands). Eleven untreated left eyes composed the control group. Twenty gauge pars plana incision 1.5 mm behind the limbus was performed in the right eyes. Twenty gauge bullet type fiberoptic endoilluminator was inserted into the eye from the incision without any pars plana vitrectomy. Fiberoptic endoilluminator was placed in such a way that it was directed toward visual streak of the rabbit retina with a 5 mm distance to retinal surface. Endoillumination was then applied for 20 min with a maximum light intensity for LED and xenon light. In left control eyes, no surgical procedure and no endoillumination were performed. One week after the endoillumination procedure, both eyes of the rabbits were enucleated following electroretinography. Sections stained with hematoxylin and eosin to evaluate morphologic changes. Retina tissues were assessed by active caspase-3 staining. There was no difference in the shape of the waveforms recorded in the eyes endoilluminated with LED light and xenon light sources compared to control eyes both before and after endoillumination application (p > 0.05). Microscopic evaluation of the retinas with hematoxylin and eosin staining demonstrated that all study groups have normal histologic properties similar to control group. No apoptosis positive cells were found within all sections in all groups. When the LED light source is used with maximum power and limited duration for endoillumination in rabbit eyes it does not produce phototoxic effects that may be detectable by electrophysiology and histology similar to xenon light.

  3. Method and apparatus for acquisition and tracking of light sources in a transient event rich environment

    NASA Technical Reports Server (NTRS)

    Bolin, Kenneth (Inventor); Flynn, David (Inventor); Fowski, Walter (Inventor); Miklus, Kenneth (Inventor); Kissh, Frank (Inventor); Abreu, Rene (Inventor)

    1993-01-01

    A method and apparatus for tracking a light source in a transient event rich environment locks on to a light source incident on a field-of-view 1 of a charge-coupled-device (CCD) array 6, validates the permanence of said light source and transmits data relating to the brilliance and location of said light source if said light source is determined to be permanent.

  4. Primer of School Lighting Lamps and Maintenance.

    ERIC Educational Resources Information Center

    Allphin, Willard

    The basic principles of the most commonly used lamp types and the circuitry which makes them operate are discussed. The two objectives of this book are to serve as a--(1) guide to economical lighting, and (2) a permanent reference source for troubleshooting. Areas dealt with include--(1) lighting fundamentals, (2) incandescent lamps, (3)…

  5. Light fields in the ocean

    NASA Technical Reports Server (NTRS)

    Pelevin, V. N.; Kozlyaninov, M. V.

    1981-01-01

    The problem of light fields in the ocean is in basic ocean optics. Twenty-six separate studies discuss: (1) the field of solar radiation in the ocean; (2) stationary and nonstationary light fields created in the sea by artificial sources; and (3) the use of optical methods to study biological and hydrodynamic characteristics of the sea.

  6. FBEYE: Analyzing Kepler light curves and validating flares

    NASA Astrophysics Data System (ADS)

    Johnson, Emily; Davenport, James R. A.; Hawley, Suzanne L.

    2017-12-01

    FBEYE, the "Flares By-Eye" detection suite, is written in IDL and analyzes Kepler light curves and validates flares. It works on any 3-column light curve that contains time, flux, and error. The success of flare identification is highly dependent on the smoothing routine, which may not be suitable for all sources.

  7. Lattice modeling and calibration with turn-by-turn orbit data

    NASA Astrophysics Data System (ADS)

    Huang, Xiaobiao; Sebek, Jim; Martin, Don

    2010-11-01

    A new method that explores turn-by-turn beam position monitor (BPM) data to calibrate lattice models of accelerators is proposed. The turn-by-turn phase space coordinates at one location of the ring are first established using data from two BPMs separated by a simple section with a known transfer matrix, such as a drift space. The phase space coordinates are then tracked with the model to predict positions at other BPMs, which can be compared to measurements. The model is adjusted to minimize the difference between the measured and predicted orbit data. BPM gains and rolls are included as fitting variables. This technique can be applied to either the entire or a section of the ring. We have tested the method experimentally on a part of the SPEAR3 ring.

  8. Green-light supplementation for enhanced lettuce growth under red- and blue-light-emitting diodes

    NASA Technical Reports Server (NTRS)

    Kim, Hyeon-Hye; Goins, Gregory D.; Wheeler, Raymond M.; Sager, John C.

    2004-01-01

    Plants will be an important component of future long-term space missions. Lighting systems for growing plants will need to be lightweight, reliable, and durable, and light-emitting diodes (LEDs) have these characteristics. Previous studies demonstrated that the combination of red and blue light was an effective light source for several crops. Yet the appearance of plants under red and blue lighting is purplish gray making visual assessment of any problems difficult. The addition of green light would make the plant leave appear green and normal similar to a natural setting under white light and may also offer a psychological benefit to the crew. Green supplemental lighting could also offer benefits, since green light can better penetrate the plant canopy and potentially increase plant growth by increasing photosynthesis from the leaves in the lower canopy. In this study, four light sources were tested: 1) red and blue LEDs (RB), 2) red and blue LEDs with green fluorescent lamps (RGB), 3) green fluorescent lamps (GF), and 4) cool-white fluorescent lamps (CWF), that provided 0%, 24%, 86%, and 51% of the total PPF in the green region of the spectrum, respectively. The addition of 24% green light (500 to 600 nm) to red and blue LEDs (RGB treatment) enhanced plant growth. The RGB treatment plants produced more biomass than the plants grown under the cool-white fluorescent lamps (CWF treatment), a commonly tested light source used as a broad-spectrum control.

  9. Non-contact pumping of light emitters via non-radiative energy transfer

    DOEpatents

    Klimov, Victor I.; Achermann, Marc

    2010-01-05

    A light emitting device is disclosed including a primary light source having a defined emission photon energy output, and, a light emitting material situated near to said primary light source, said light emitting material having an absorption onset equal to or less in photon energy than the emission photon energy output of the primary light source whereby non-radiative energy transfer from said primary light source to said light emitting material can occur yielding light emission from said light emitting material.

  10. Size- and density-distributions and sources of polycyclic aromatic hydrocarbons in urban road dust.

    PubMed

    Murakami, Michio; Nakajima, Fumiyuki; Furumai, Hiroaki

    2005-11-01

    Polycyclic aromatic hydrocarbons (PAHs) present in size- and density-fractionated road dust were measured to identify the important fractions in urban runoff and to analyse their sources. Road dust was collected from a residential area (Shakujii) and a heavy traffic area (Hongo Street). The sampling of road dust from the residential area was conducted twice in different seasons (autumn and winter). The collected road dust was separated into three or four size-fractions and further fractionated into light (<1.7 g/cm3) and heavy (>1.7 g/cm3) fractions by using cesium chloride solution. Light particles constituted only 4.0+/-1.4%, 0.69+/-0.03% and 3.4+/-1.0% of the road dust by weight for Shakujii (November), Shakujii (February) and Hongo Street, respectively but contained 28+/-10%, 33+/-3% and 44+/-8% of the total PAHs, respectively. The PAH contents in the light fractions were 1-2 orders of magnitude higher than those in the heavy fractions. In the light fractions, the 12PAH contents in February were significantly higher than the 12PAH contents in November (P<0.01), whereas in the heavy fractions, no significant difference was found (P>0.05). Cluster analysis revealed that there was a significant difference in the PAH profiles between locations rather than between size-fractions, density-fractions and sampling times. Multiple regression analysis indicated that asphalt/pavement was the major source of Shakujii road dust, and that tyre and diesel vehicle exhaust were the major sources of finer and coarser fractions collected from Hongo Street road dust, respectively.

  11. To compute lightness, illumination is not estimated, it is held constant.

    PubMed

    Gilchrist, Alan L

    2018-05-03

    The light reaching the eye from a surface does not indicate the black-gray-white shade of a surface (called lightness) because the effects of illumination level are confounded with the reflectance of the surface. Rotating a gray paper relative to a light source alters its luminance (intensity of light reaching the eye) but the lightness of the paper remains relatively constant. Recent publications have argued, as had Helmholtz (1866/1924), that the visual system unconsciously estimates the direction and intensity of the light source. We report experiments in which this theory was pitted against an alternative theory according to which illumination level and surface reflectance are disentangled by comparing only those surfaces that are equally illuminated, in other words, by holding illumination level constant. A 3-dimensional scene was created within which the rotation of a target surface would be expected to become darker gray according to the lighting estimation theory, but lighter gray according to the equi-illumination comparison theory, with results clearly favoring the latter. In a further experiment cues held to indicate light source direction (cast shadows, attached shadows, and glossy highlights) were completely eliminated and yet this had no effect on the results. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  12. Violet Laser Diode Enables Lighting Communication.

    PubMed

    Chi, Yu-Chieh; Huang, Yu-Fang; Wu, Tsai-Chen; Tsai, Cheng-Ting; Chen, Li-Yin; Kuo, Hao-Chung; Lin, Gong-Ru

    2017-09-05

    Violet laser diode (VLD) based white-light source with high color rendering index (CRI) for lighting communication is implemented by covering with Y 3 Al 5 O 12 :Ce 3+ (YAG:Ce) or Lu 3 Al 5 O 12 :Ce 3+ /CaAlSiN 3 :Eu 2+ (LuAG:Ce/CASN:Eu) phosphorous diffuser plates. After passing the beam of VLD biased at 70 mA (~2I th ) through the YAG:Ce phosphorous diffuser, a daylight with a correlated color temperature (CCT) of 5068 K and a CRI of 65 is acquired to provide a forward error correction (FEC) certified data rate of 4.4 Gbit/s. By using the VLD biased at 122 mA (~3.5I th ) to excite the LuAG:Ce/CASN:Eu phosphorous diffuser with 0.85-mm thickness, a warm white-light source with a CCT of 2700 K and a CRI of 87.9 is obtained at a cost of decreasing transmission capacity to 2.4 Gbit/s. Thinning the phosphor thickness to 0.75 mm effectively reduces the required bias current by 32 mA to achieve the same CCT for the delivered white light, which offers an enlarged CRI of 89.1 and an increased data rate of 4.4 Gbit/s. Further enlarging the bias current to 105 mA remains the white-light transmission capacity at 4.4 Gbit/s but reveals an increased CCT of 3023 K and an upgraded CRI of 91.5.

  13. A 3D radiative transfer model based on lidar data and its application on hydrological and ecosystem modeling

    NASA Astrophysics Data System (ADS)

    Li, W.; Su, Y.; Harmon, T. C.; Guo, Q.

    2013-12-01

    Light Detection and Ranging (lidar) is an optical remote sensing technology that measures properties of scattered light to find range and/or other information of a distant object. Due to its ability to generate 3-dimensional data with high spatial resolution and accuracy, lidar technology is being increasingly used in ecology, geography, geology, geomorphology, seismology, remote sensing, and atmospheric physics. In this study we construct a 3-dimentional (3D) radiative transfer model (RTM) using lidar data to simulate the spatial distribution of solar radiation (direct and diffuse) on the surface of water and mountain forests. The model includes three sub-models: a light model simulating the light source, a sensor model simulating the camera, and a scene model simulating the landscape. We use ground-based and airborne lidar data to characterize the 3D structure of the study area, and generate a detailed 3D scene model. The interactions between light and object are simulated using the Monte Carlo Ray Tracing (MCRT) method. A large number of rays are generated from the light source. For each individual ray, the full traveling path is traced until it is absorbed or escapes from the scene boundary. By locating the sensor at different positions and directions, we can simulate the spatial distribution of solar energy at the ground, vegetation and water surfaces. These outputs can then be incorporated into meteorological drivers for hydrologic and energy balance models to improve our understanding of hydrologic processes and ecosystem functions.

  14. Important fossil source contribution to brown carbon in Beijing during winter

    NASA Astrophysics Data System (ADS)

    Yan, Caiqing; Zheng, Mei; Bosch, Carme; Andersson, August; Desyaterik, Yury; Sullivan, Amy P.; Collett, Jeffrey L.; Zhao, Bin; Wang, Shuxiao; He, Kebin; Gustafsson, Örjan

    2017-03-01

    Organic aerosol (OA) constitutes a substantial fraction of fine particles and affects both human health and climate. It is becoming clear that OA absorbs light substantially (hence termed Brown Carbon, BrC), adding uncertainties to global aerosol radiative forcing estimations. The few current radiative-transfer and chemical-transport models that include BrC primarily consider sources from biogenic and biomass combustion. However, radiocarbon fingerprinting here clearly indicates that light-absorbing organic carbon in winter Beijing, the capital of China, is mainly due to fossil sources, which contribute the largest part to organic carbon (OC, 67 ± 3%) and its sub-constituents (water-soluble OC, WSOC: 54 ± 4%, and water-insoluble OC, WIOC: 73 ± 3%). The dual-isotope (Δ14C/δ13C) signatures, organic molecular tracers and Beijing-tailored emission inventory identify that this fossil source is primarily from coal combustion activities in winter, especially from the residential sector. Source testing on Chinese residential coal combustion provides direct evidence that intensive coal combustion could contribute to increased light-absorptivity of ambient BrC in Beijing winter. Coal combustion is an important source to BrC in regions such as northern China, especially during the winter season. Future modeling of OA radiative forcing should consider the importance of both biomass and fossil sources.

  15. Important fossil source contribution to brown carbon in Beijing during winter

    PubMed Central

    Yan, Caiqing; Zheng, Mei; Bosch, Carme; Andersson, August; Desyaterik, Yury; Sullivan, Amy P.; Collett, Jeffrey L.; Zhao, Bin; Wang, Shuxiao; He, Kebin; Gustafsson, Örjan

    2017-01-01

    Organic aerosol (OA) constitutes a substantial fraction of fine particles and affects both human health and climate. It is becoming clear that OA absorbs light substantially (hence termed Brown Carbon, BrC), adding uncertainties to global aerosol radiative forcing estimations. The few current radiative-transfer and chemical-transport models that include BrC primarily consider sources from biogenic and biomass combustion. However, radiocarbon fingerprinting here clearly indicates that light-absorbing organic carbon in winter Beijing, the capital of China, is mainly due to fossil sources, which contribute the largest part to organic carbon (OC, 67 ± 3%) and its sub-constituents (water-soluble OC, WSOC: 54 ± 4%, and water-insoluble OC, WIOC: 73 ± 3%). The dual-isotope (Δ14C/δ13C) signatures, organic molecular tracers and Beijing-tailored emission inventory identify that this fossil source is primarily from coal combustion activities in winter, especially from the residential sector. Source testing on Chinese residential coal combustion provides direct evidence that intensive coal combustion could contribute to increased light-absorptivity of ambient BrC in Beijing winter. Coal combustion is an important source to BrC in regions such as northern China, especially during the winter season. Future modeling of OA radiative forcing should consider the importance of both biomass and fossil sources. PMID:28266611

  16. A Novel Approach to model EPIC variable background

    NASA Astrophysics Data System (ADS)

    Marelli, M.; De Luca, A.; Salvetti, D.; Belfiore, A.

    2017-10-01

    One of the main aim of the EXTraS (Exploring the X-ray Transient and variable Sky) project is to characterise the variability of serendipitous XMM-Newton sources within each single observation. Unfortunately, 164 Ms out of the 774 Ms of cumulative exposure considered (21%) are badly affected by soft proton flares, hampering any classical analysis of field sources. De facto, the latest releases of the 3XMM catalog, as well as most of the analysis in literature, simply exclude these 'high background' periods from analysis. We implemented a novel SAS-indipendent approach to produce background-subtracted light curves, which allows to treat the case of very faint sources and very bright proton flares. EXTraS light curves of 3XMM-DR5 sources will be soon released to the community, together with new tools we are developing.

  17. Sharpening the Tip of the Spear: Preparing Special Forces Detachment Commanders for the Future

    DTIC Science & Technology

    2008-05-19

    Persian Farsi, Korean, and Thai ) is 24 weeks long. Soldiers must successfully pass the Defense Language Proficiency Test (DLPT) by demonstrating...Brief (Fort Bragg, NC: 2007), 2. 29 real world GWOT project in coordination with one of the Theatre Special Operation Commands (TSOC).89 Weeks 13...Forces (JSOTF) with parallel major general Division commanders within theatre ? A second suggestion for future research begins with the question

  18. Blunting the Spear: Why Good People Get Out

    DTIC Science & Technology

    2015-03-01

    Viewed from afar, it appears audacious and self -serving. Upon closer inspection, this same attitude becomes determinant in a fighter pilot’s...tributions to education in the Royal Netherlands Air Force. The Drew Papers are dedicated to promoting the understanding of air and space power theory and...across the finish line—thank you. I would also like to recognize Ms. Sophie Ryan and Ms. Arden Gale. With- out their help, the statistical analysis and

  19. Swarming and the Future of Warfare

    DTIC Science & Technology

    2005-01-01

    the horse archers swarmed around the square and began delivering arrows and spears from standoff range. As Plutarch described it, "The Parthians thus...cutting it off, surrounded and annihilated it. The harassment of the main body continued until nightfall, when the darkness prevented 2 Plutarch ...Plaster, John L. SOG: The Secret Wars of America’s Commandos in Vietnam. New York, NY: Penguin Group, 1997. Plutarch . Selected Lives from the Lives of Noble

  20. Command Liaison at the Corps Level.

    DTIC Science & Technology

    1983-05-20

    not bring them together, for they disliked each other’s cuisine . When, owing to the sudden German onslaught on Verdun, the Tenth French Army was...and strategies, and personalities into a cohesive fighting force. BRITISH/ FRENCH The most complete recount of liaison in WW I (or any other conflict for...that matter) is that written by E. Spears concerning his activities as a young lieutenant liaison officer from the British to the French Army. In the

  1. AGARD Flight Test Instrumentation Series. Volume 15. Gyroscopic Instruments and Their Application to Flight Testing

    DTIC Science & Technology

    1982-09-01

    center of gravity, Eq. (J.Z.,5)r [in radius of light been, Eq. (3.5.1) r aplitude of baCkscattere•d light with respect to incident light of a mirror , Eq...output, see Eq. (3.5.9)). High quality sensors are being4 built using three or more mirrors within a linear dimension of 10 co. At the present time...Fig. 3.5.1, showed an effect. The SRI shown in fjt.ýj consists of a light source (LS). a beam splitter (8S). three fully re- flecting; mirrors ,. M1I.iF

  2. Intense XUV (Extreme Ultraviolet) Radiation Sources.

    DTIC Science & Technology

    1985-07-31

    Light Sources for High ................ .29 . Resolution XUV and VUV Spectroscopy; Appendix F:’High Resolution Spectra of Laser Pl -asma Light...34."" ."."".". "," .. .". .’ Laser (1.06juMm) iol 3 Target Intensit vrV Pls htN Ta disk 3 - I O WlCnr 4. K 2.2 ns 80100209 > 1~ C 1010 109 0 40 80 120 160 200 240...acknowledges support from SERC (UK). 1. Carroll, P.K., Kennedy, E.T. and O’Sullivan, G., 1980, App. Opt. 19, 1454. 2. Nagel, D.J., Brown, C.M., Peckerar

  3. Phosphor blends for high-CRI fluorescent lamps

    DOEpatents

    Setlur, Anant Achyut [Niskayuna, NY; Srivastava, Alok Mani [Niskayuna, NY; Comanzo, Holly Ann [Niskayuna, NY; Manivannan, Venkatesan [Clifton Park, NY; Beers, William Winder [Chesterland, OH; Toth, Katalin [Pomaz, HU; Balazs, Laszlo D [Budapest, HU

    2008-06-24

    A phosphor blend comprises at least two phosphors each selected from one of the groups of phosphors that absorb UV electromagnetic radiation and emit in a region of visible light. The phosphor blend can be applied to a discharge gas radiation source to produce light sources having high color rendering index. A phosphor blend is advantageously includes the phosphor (Tb,Y,LuLa,Gd).sub.x(Al,Ga).sub.yO.sub.12:Ce.sup.3+, wherein x is in the range from about 2.8 to and including 3 and y is in the range from about 4 to and including 5.

  4. Low Illumination Light (LIL) Solar Cells: Indoor and Monochromatic Light Harvesting

    DTIC Science & Technology

    2015-11-01

    photovoltaic ( PV ) solar cells under low intensity and narrow light spectrum conditions has not been clearly examined. PV operating values under 1 sun...3. PV Fundamental Losses under Low-Light Conditions 5 4. Experiment Setup 9 4.1 Materials 9 4.1.1 Light Sources and Spectra 9 4.1.2 PV Solar ...http://www.mjinc.com/newsArticle2012_Mar15.html ..........................4 Fig. 4 Three energy and power densities ranges for PV solar cells

  5. A Planar, Chip-Based, Dual-Beam Refractometer Using an Integrated Organic Light Emitting Diode (OLED) Light Source and Organic Photovoltaic (OPV) Detectors

    PubMed Central

    Ratcliff, Erin L.; Veneman, P. Alex; Simmonds, Adam; Zacher, Brian; Huebner, Daniel

    2010-01-01

    We present a simple chip-based refractometer with a central organic light emitting diode (OLED) light source and two opposed organic photovoltaic (OPV) detectors on an internal reflection element (IRE) substrate, creating a true dual-beam sensor platform. For first-generation platforms, we demonstrate the use of a single heterojunction OLED based on electroluminescence emission from an Alq3/TPD heterojunction (tris-(8-hydroxyquinoline)aluminum/N,N′-Bis(3-methylphenyl)-N,N′-diphenylbenzidine) and light detection with planar heterojunction pentacene/C60 OPVs. The sensor utilizes the considerable fraction of emitted light from conventional thin film OLEDs that is coupled into guided modes in the IRE instead of into the forward (display) direction. A ray-optics description is used to describe light throughput and efficiency-limiting factors for light coupling from the OLED into the substrate modes, light traversing through the IRE substrate, and light coupling into the OPV detectors. The arrangement of the OLED at the center of the chip provides for two sensing regions, a “sample” and “reference” channel, with detection of light by independent OPV detectors. This configuration allows for normalization of the sensor response against fluctuations in OLED light output, stability, and local fluctuations (temperature) which might influence sensor response. The dual beam configuration permits significantly enhanced sensitivity to refractive index changes relative to single-beam protocols, and is easily integrated into a field-portable instrumentation package. Changes in refractive index (ΔR.I.) between 10−2 and 10−3 R.I. units could be detected for single channel operation, with sensitivity increased to ΔR.I. ≈ 10−4 units when the dual beam configuration is employed. PMID:20218580

  6. The Inherent Visible Light Signature of an Intense Underwater Ultraviolet Light Source Due to Combined Raman and Fluorescence Effects

    DTIC Science & Technology

    2000-01-01

    Humans cannot see ultraviolet light. The blue-sensitive cones in the retina would respond weakly to ultraviolet wavelengths if exposed to them, but...545, 1992. 3. C. S. Yentsch, and D. A. Phinney, " Autofluorescence and Raman scattering in the marine underwater environment," Ocean Optics X, SPIE

  7. 3D reconstruction of internal structure of animal body using near-infrared light

    NASA Astrophysics Data System (ADS)

    Tran, Trung Nghia; Yamamoto, Kohei; Namita, Takeshi; Kato, Yuji; Shimizu, Koichi

    2014-03-01

    To realize three-dimensional (3D) optical imaging of the internal structure of animal body, we have developed a new technique to reconstruct CT images from two-dimensional (2D) transillumination images. In transillumination imaging, the image is blurred due to the strong scattering in the tissue. We had developed a scattering suppression technique using the point spread function (PSF) for a fluorescent light source in the body. In this study, we have newly proposed a technique to apply this PSF for a light source to the image of unknown light-absorbing structure. The effectiveness of the proposed technique was examined in the experiments with a model phantom and a mouse. In the phantom experiment, the absorbers were placed in the tissue-equivalent medium to simulate the light-absorbing organs in mouse body. Near-infrared light was illuminated from one side of the phantom and the image was recorded with CMOS camera from another side. Using the proposed techniques, the scattering effect was efficiently suppressed and the absorbing structure can be visualized in the 2D transillumination image. Using the 2D images obtained in many different orientations, we could reconstruct the 3D image. In the mouse experiment, an anesthetized mouse was held in an acrylic cylindrical holder. We can visualize the internal organs such as kidneys through mouse's abdomen using the proposed technique. The 3D image of the kidneys and a part of the liver were reconstructed. Through these experimental studies, the feasibility of practical 3D imaging of the internal light-absorbing structure of a small animal was verified.

  8. Heating device for semiconductor wafers

    DOEpatents

    Vosen, Steven R.

    1999-01-01

    An apparatus for heat treating semiconductor wafers is disclosed. The apparatus includes a heating device which contains an assembly of light energy sources for emitting light energy onto a wafer. In particular, the light energy sources are positioned such that many different radial heating zones are created on a wafer being heated. For instance, in one embodiment, the light energy sources form a spiral configuration. In an alternative embodiment, the light energy sources appear to be randomly dispersed with respect to each other so that no discernable pattern is present. In a third alternative embodiment of the present invention, the light energy sources form concentric rings. Tuning light sources are then placed in between the concentric rings of light.

  9. Heating device for semiconductor wafers

    DOEpatents

    Vosen, S.R.

    1999-07-27

    An apparatus for heat treating semiconductor wafers is disclosed. The apparatus includes a heating device which contains an assembly of light energy sources for emitting light energy onto a wafer. In particular, the light energy sources are positioned such that many different radial heating zones are created on a wafer being heated. For instance, in one embodiment, the light energy sources form a spiral configuration. In an alternative embodiment, the light energy sources appear to be randomly dispersed with respect to each other so that no discernible pattern is present. In a third alternative embodiment of the present invention, the light energy sources form concentric rings. Tuning light sources are then placed in between the concentric rings of light. 4 figs.

  10. Stellar Alchemy

    NASA Astrophysics Data System (ADS)

    Cassé, Michel; Lyle, Translated by Stephen

    2003-08-01

    Preface; 1. Nuclear astrophysics: defence and illustration; 2. Light from atoms, light from the sky; 3. Visions; 4. Contents of the sky: atomic sources and fountains; 5. Nuclear suns; 6. Sociology of stars and clouds; 7. Histories; 8. Ancient stars in the galactic halo; 9. Conclusion; Appendices.

  11. Programmable Spectral Source and Design Tool for 3D Imaging Using Complementary Bandpass Filters

    NASA Technical Reports Server (NTRS)

    Bae, Youngsam (Inventor); Korniski, Ronald J. (Inventor); Ream, Allen (Inventor); Shearn, Michael J. (Inventor); Shahinian, Hrayr Karnig (Inventor); Fritz, Eric W. (Inventor)

    2017-01-01

    An endoscopic illumination system for illuminating a subject for stereoscopic image capture, includes a light source which outputs light; a first complementary multiband bandpass filter (CMBF) and a second CMBF, the first and second CMBFs being situated in first and second light paths, respectively, where the first CMBF and the second CMBF filter the light incident thereupon to output filtered light; and a camera which captures video images of the subject and generates corresponding video information, the camera receiving light reflected from the subject and passing through a pupil CMBF pair and a detection lens. The pupil CMBF includes a first pupil CMBF and a second pupil CMBF, the first pupil CMBF being identical to the first CMBF and the second pupil CMBF being identical to the second CMBF, and the detection lens includes one unpartitioned section that covers both the first pupil CMBF and the second pupil CMBF.

  12. Noncoherent-intense-pulsed light for the treatment of relapsing hairy intradermal melanocytic nevus after shave excision.

    PubMed

    Moreno-Arias, G A; Ferrando, J

    2001-01-01

    Few reports about melanocytic lesions treatment by means of noncoherent-intense-pulsed light (NCIPL) have been published. Here we evaluate the clinical results of a relapsing hairy intradermal melanocytic nevus treated with a noncoherent-intense-pulsed light source. A facial repigmented hairy intradermal melanocytic nevus that relapsed after shave excision, received four treatment sessions of a noncoherent-intense-pulsed light source (EpiLight, ESC Medical Systems Ltd, Israel) with the following parameters: 755 nm, a fluence energy of 40-42.5 J/cm(2), triple mode, a pulse width of 3.8 ms, and a delay of 20 ms, at 4-week intervals. Complete pigment clearance and hair removal was obtained. We have neither observed repigmentation nor hair regrowth after a 6 month-follow-up. No side effects were documented. Noncoherent-intense-pulse light is an effective treatment for hairy-pigmented melanocytic nevus. Copyright 2001 Wiley-Liss, Inc.

  13. The Soviet program for peaceful uses of nuclear explosions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nordyke, M.D.

    1996-07-24

    The concept of utilizing the weapons of war to serve the peaceful pursuits of mankind is as old as civilization itself. Perhaps the most famous reference to this basic desire is recorded in the Book of Micah where the great prophet Isiah called upon his people `to turn your spears into pitchforks and your swords into plowshares.` As the scientists at Los Alamos worked on developing the world`s first atomic bomb, thoughts of how this tremendous new source of energy could be used for peaceful purposes generally focused on using the thermal energy generated by the slow fission of uraniummore » in a reactor, such as those being used to produce Plutonium to drive electric power stations. However, being scientists in a new, exciting field, it was impossible to avoid letting their minds wander from the task at hand to other scientific or non-military uses for the bombs themselves. During the Manhattan Project, Otto Frisch, one of the pioneers in the development of nuclear fission process in the 1930s, first suggested using an atomic explosion as a source for a large quantities of neutrons which could used in scientific experiments designed to expand their understanding of nuclear physics. After the war was over, many grandiose ideas appeared in the popular press on how this new source of energy should be to serve mankind. Not to be left out of the growing enthusiasm for peaceful uses of atomic energy, the Soviet Union added their visions to the public record. This document details the Soviet program for using nuclear explosions in peacetime pursuits.« less

  14. Stray light in cone beam optical computed tomography: I. Measurement and reduction strategies with planar diffuse source

    NASA Astrophysics Data System (ADS)

    Granton, Patrick V.; Dekker, Kurtis H.; Battista, Jerry J.; Jordan, Kevin J.

    2016-04-01

    Optical cone-beam computed tomographic (CBCT) scanning of 3D radiochromic dosimeters may provide a practical method for 3D dose verification in radiation therapy. However, in cone-beam geometry stray light contaminates the projection images, degrading the accuracy of reconstructed linear attenuation coefficients. Stray light was measured using a beam pass aperture array (BPA) and structured illumination methods. The stray-to-primary ray ratio (SPR) along the central axis was found to be 0.24 for a 5% gelatin hydrogel, representative of radiochromic hydrogels. The scanner was modified by moving the spectral filter from the detector to the source, changing the light’s spatial fluence pattern and lowering the acceptance angle by extending distance between the source and object. These modifications reduced the SPR significantly from 0.24 to 0.06. The accuracy of the reconstructed linear attenuation coefficients for uniform carbon black liquids was compared to independent spectrometer measurements. Reducing the stray light increased the range of accurate transmission readings. In order to evaluate scanner performance for the more challenging application to small field dosimetry, a carbon black finger gel phantom was prepared. Reconstructions of the phantom from CBCT and fan-beam CT scans were compared. The modified source resulted in improved agreement. Subtraction of residual stray light, measured with BPA or structured illumination from each projection further improved agreement. Structured illumination was superior to BPA for measuring stray light for the smaller 1.2 and 0.5 cm diameter phantom fingers. At the costs of doubling the scanner size and tripling the number of scans, CBCT reconstructions of low-scattering hydrogel dosimeters agreed with those of fan-beam CT scans.

  15. OGLE-2015-BLG-1459L: The Challenges of Exo-moon Microlensing

    NASA Astrophysics Data System (ADS)

    Hwang, K.-H.; Udalski, A.; Bond, I. A.; Albrow, M. D.; Chung, S.-J.; Gould, A.; Han, C.; Jung, Y. K.; Ryu, Y.-H.; Shin, I.-G.; Yee, J. C.; Zhu, W.; Cha, S.-M.; Kim, D.-J.; Kim, H.-W.; Kim, S.-L.; Lee, C.-U.; Lee, D.-J.; Lee, Y.; Park, B.-G.; Pogge, R. W.; KMTNet Collaboration; Pawlak, M.; Poleski, R.; Szymański, M. K.; Skowron, J.; Soszyński, I.; Mróz, P.; Kozłowski, S.; Pietrukowicz, P.; Ulaczyk, K.; OGLE Collaboration; Abe, F.; Asakura, Y.; Barry, R.; Bennett, D. P.; Bhattacharya, A.; Donachie, M.; Evans, P.; Fukui, A.; Hirao, Y.; Itow, Y.; Kawasaki, K.; Koshimoto, N.; Li, M. C. A.; Ling, C. H.; Masuda, K.; Matsubara, Y.; Miyazaki, S.; Muraki, Y.; Nagakane, M.; Ohnishi, K.; Ranc, C.; Rattenbury, N. J.; Saito, To.; Sharan, A.; Sullivan, D. J.; Sumi, T.; Suzuki, D.; Tristram, P. J.; Yamada, T.; Yamada, T.; Yonehara, A.; MOA Collaboration

    2018-06-01

    We show that dense OGLE and KMTNet I-band survey data require four bodies (sources plus lenses) to explain the microlensing light curve of OGLE-2015-BLG-1459. However, these can equally well consist of three lenses and one source (3L1S), two lenses and two sources (2L2S), or one lens and three sources (1L3S). In the 3L1S and 2L2S interpretations, the host is a brown dwarf and the dominant companion is a Neptune-class planet, with the third body (in the 3L1S case) being a Mars-class object that could have been a moon of the planet. In the 1L3S solution, the light curve anomalies are explained by a tight (five stellar radii) low-luminosity binary source that is offset from the principal source of the event by ∼ 0.17 {au}. These degeneracies are resolved in favor of the 1L3S solution by color effects derived from comparison to MOA data, which are taken in a slightly different (R/I) passband. To enable current and future (WFIRST) surveys to routinely characterize exo-moons and distinguish among such exotic systems requires an observing strategy that includes both a cadence faster than 9 minute‑1 and observations in a second band on a similar timescale.

  16. Nonimaging Optical Illumination System

    DOEpatents

    Winston, Roland

    1994-08-02

    A nonimaging illumination optical device for producing selected intensity output over an angular range. The device includes a light reflecting surface (24, 26) around a light source (22) which is disposed opposite the aperture opening of the light reflecting surface (24, 26). The light source (22) has a characteristic dimension which is small relative to one or more of the distance from the light source (22) to the light reflecting surface (24, 26) or the angle subtended by the light source (22) at the light reflecting surface (24, 26).

  17. Development of a circadian light source

    NASA Astrophysics Data System (ADS)

    Nicol, David B.; Ferguson, Ian T.

    2002-11-01

    Solid state lighting presents a new paradigm for lighting - controllability. Certain characteristics of the lighting environment can be manipulated, because of the possibility of using multiple LEDs of different emission wavelengths as the illumination source. This will provide a new, versatile, general illumination source due to the ability to vary the spectral power distribution. New effects beyond the visual may be achieved that are not possible with conventional light sources. Illumination has long been the primary function of lighting but as the lighting industry has matured the psychological aspects of lighting have been considered by designers; for example, choosing a particular lighting distribution or color variation in retail applications. The next step in the evolution of light is to consider the physiological effects of lighting that cause biological changes in a person within the environment. This work presents the development of a source that may have important bearing on this area of lighting. A circadian light source has been developed to provide an illumination source that works by modulating its correlated color temperature to mimic the changes in natural daylight through the day. In addition, this source can cause or control physiological effects for a person illuminated by it. The importance of this is seen in the human circadian rhythm's peak response corresponding to blue light at ~460 nm which corresponds to the primary spectral difference in increasing color temperature. The device works by adding blue light to a broadband source or mixing polychromatic light to mimic the variation of color temperature observed for the Planckian Locus on the CIE diagram. This device can have several applications including: a tool for researchers in this area, a general illumination lighting technology, and a light therapy device.

  18. A tuneable approach to uniform light distribution for artificial daylight photodynamic therapy.

    PubMed

    O'Mahoney, Paul; Haigh, Neil; Wood, Kenny; Brown, C Tom A; Ibbotson, Sally; Eadie, Ewan

    2018-06-16

    Implementation of daylight photodynamic therapy (dPDT) is somewhat limited by variable weather conditions. Light sources have been employed to provide artificial dPDT indoors, with low irradiances and longer treatment times. Uniform light distribution across the target area is key to ensuring effective treatment, particularly for large areas. A novel light source is developed with tuneable direction of light emission in order to meet this challenge. Wavelength composition of the novel light source is controlled such that the protoporphyrin-IX (PpIX) weighed spectra of both the light source and daylight match. The uniformity of the light source is characterised on a flat surface, a model head and a model leg. For context, a typical conventional PDT light source is also characterised. Additionally, the wavelength uniformity across the treatment site is characterised. The PpIX-weighted spectrum of the novel light source matches with PpIX-weighted daylight spectrum, with irradiance values within the bounds for effective dPDT. By tuning the direction of light emission, improvements are seen in the uniformity across large anatomical surfaces. Wavelength uniformity is discussed. We have developed a light source that addresses the challenges in uniform, multiwavelength light distribution for large area artificial dPDT across curved anatomical surfaces. Copyright © 2018. Published by Elsevier B.V.

  19. Micro optical fiber light source and sensor and method of fabrication thereof

    DOEpatents

    Kopelman, Raoul; Tan, Weihong; Shi, Zhong-You

    1997-01-01

    This invention relates generally to the development of and a method of fabricating a fiber optic micro-light source and sensor (50). An optical fiber micro-light source (50) is presented whose aperture is extremely small yet able to act as an intense light source. Light sources of this type have wide ranging applications, including use as micro-sensors (22) in NSOM. Micro-sensor light sources have excellent detection limits as well as photo stability, reversibility, and millisecond response times. Furthermore, a method for manufacturing a micro optical fiber light source is provided. It involves the photo-chemical attachment of an optically active material onto the end surface of an optical fiber cable which has been pulled to form an end with an extremely narrow aperture. More specifically, photopolymerization has been applied as a means to photo-chemically attach an optically active material (60). This process allows significant control of the size of the micro light source (50). Furthermore, photo-chemically attaching an optically active material (60) enables the implementation of the micro-light source in a variety of sensor applications.

  20. Micro optical fiber light source and sensor and method of fabrication thereof

    DOEpatents

    Kopelman, Raoul; Tan, Weihong; Shi, Zhong-You

    1994-01-01

    This invention relates generally to the development of and a method of fabricating a micro optical fiber light source. An optical fiber micro-light source is presented whose aperture is extremely small yet able to act as an intense light source. Light sources of this type have wide ranging applications, including use as micro-sensors in NSOM. Micro-sensor light sources have excellent detection limits as well as photo stability, reversibility, and millisecond response times. Furthermore, a method for manufacturing a micro optical fiber light source is provided. It involves the photo-chemical attachment of an optically active material onto the end surface of an optical fiber cable which has been pulled to form an end with an extremely narrow aperture. More specifically, photopolymerization has been applied as a means to photo-chemically attach an optically active material. This process allows significant control of the size of the micro light source. Furthermore, photo-chemically attaching an optically active material enables the implementation of the micro-light source in a variety of sensor applications.

  1. Micro optical fiber light source and sensor and method of fabrication thereof

    DOEpatents

    Kopelman, R.; Tan, W.; Shi, Z.Y.

    1997-05-06

    This invention relates generally to the development of and a method of fabricating a fiber optic micro-light source and sensor. An optical fiber micro-light source is presented whose aperture is extremely small yet able to act as an intense light source. Light sources of this type have wide ranging applications, including use as micro-sensors in NSOM. Micro-sensor light sources have excellent detection limits as well as photo stability, reversibility, and millisecond response times. Furthermore, a method for manufacturing a micro optical fiber light source is provided. It involves the photo-chemical attachment of an optically active material onto the end surface of an optical fiber cable which has been pulled to form an end with an extremely narrow aperture. More specifically, photopolymerization has been applied as a means to photo-chemically attach an optically active material. This process allows significant control of the size of the micro light source. Furthermore, photo-chemically attaching an optically active material enables the implementation of the micro-light source in a variety of sensor applications. 10 figs.

  2. Micro optical fiber light source and sensor and method of fabrication thereof

    DOEpatents

    Kopelman, R.; Tan, W.; Shi, Z.Y.

    1994-11-01

    This invention relates generally to the development of and a method of fabricating a micro optical fiber light source. An optical fiber micro-light source is presented whose aperture is extremely small yet able to act as an intense light source. Light sources of this type have wide ranging applications, including use as micro-sensors in NSOM. Micro-sensor light sources have excellent detection limits as well as photo stability, reversibility, and millisecond response times. Furthermore, a method for manufacturing a micro optical fiber light source is provided. It involves the photo-chemical attachment of an optically active material onto the end surface of an optical fiber cable which has been pulled to form an end with an extremely narrow aperture. More specifically, photopolymerization has been applied as a means to photo-chemically attach an optically active material. This process allows significant control of the size of the micro light source. Furthermore, photo-chemically attaching an optically active material enables the implementation of the micro-light source in a variety of sensor applications. 4 figs.

  3. Visible light photocatalysis as a greener approach to photochemical synthesis.

    PubMed

    Yoon, Tehshik P; Ischay, Michael A; Du, Juana

    2010-07-01

    Light can be considered an ideal reagent for environmentally friendly, 'green' chemical synthesis; unlike many conventional reagents, light is non-toxic, generates no waste, and can be obtained from renewable sources. Nevertheless, the need for high-energy ultraviolet radiation in most organic photochemical processes has limited both the practicality and environmental benefits of photochemical synthesis on industrially relevant scales. This perspective describes recent approaches to the use of metal polypyridyl photocatalysts in synthetic organic transformations. Given the remarkable photophysical properties of these complexes, these new transformations, which use Ru(bpy)(3)(2+) and related photocatalysts, can be conducted using almost any source of visible light, including both store-bought fluorescent light bulbs and ambient sunlight. Transition metal photocatalysis thus represents a promising strategy towards the development of practical, scalable industrial processes with great environmental benefits.

  4. The linac coherent light source single particle imaging road map

    PubMed Central

    Aquila, A.; Barty, A.; Bostedt, C.; Boutet, S.; Carini, G.; dePonte, D.; Drell, P.; Doniach, S.; Downing, K. H.; Earnest, T.; Elmlund, H.; Elser, V.; Gühr, M.; Hajdu, J.; Hastings, J.; Hau-Riege, S. P.; Huang, Z.; Lattman, E. E.; Maia, F. R. N. C.; Marchesini, S.; Ourmazd, A.; Pellegrini, C.; Santra, R.; Schlichting, I.; Schroer, C.; Spence, J. C. H.; Vartanyants, I. A.; Wakatsuki, S.; Weis, W. I.; Williams, G. J.

    2015-01-01

    Intense femtosecond x-ray pulses from free-electron laser sources allow the imaging of individual particles in a single shot. Early experiments at the Linac Coherent Light Source (LCLS) have led to rapid progress in the field and, so far, coherent diffractive images have been recorded from biological specimens, aerosols, and quantum systems with a few-tens-of-nanometers resolution. In March 2014, LCLS held a workshop to discuss the scientific and technical challenges for reaching the ultimate goal of atomic resolution with single-shot coherent diffractive imaging. This paper summarizes the workshop findings and presents the roadmap toward reaching atomic resolution, 3D imaging at free-electron laser sources. PMID:26798801

  5. The linac coherent light source single particle imaging road map

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aquila, A.; Barty, A.; Bostedt, C.

    Intense femtosecond x-ray pulses from free-electron laser sources allow the imaging of individual particles in a single shot. Early experiments at the Linac Coherent Light Source (LCLS) have led to rapid progress in the field and, so far, coherent diffractive images have been recorded from biological specimens, aerosols, and quantum systems with a few-tens-of-nanometers resolution. In March 2014, LCLS held a workshop to discuss the scientific and technical challenges for reaching the ultimate goal of atomic resolution with single-shot coherent diffractive imaging. This paper summarizes the workshop findings and presents the roadmap toward reaching atomic resolution, 3D imaging at free-electronmore » laser sources.« less

  6. Civilians at the Tip of the Spear: Civilian Issues Commanders Encounter During Deployments

    DTIC Science & Technology

    2002-04-01

    Service, May 1996; Staff Sgt. Kathleen T. Rhem, �Civilians Vital to DoD Mission,� American Forces Information Service, June 2000. 6 Edwin Dorn...Serge Lazareff, Status of Military Forces Under Current International Law (A.W. Sijthoff, Leyden , Netherlands 1971), 77. 2 James Maloney Spaight, 1911... Kathleen A. Bannister, �One-Stop Shopping at CECOM,� Army Logistics, January- February 1999. 83 Major Mike O. Lacey, CDR Brian J. Bill, eds., Operational

  7. Space Experiments Aboard Rockets: SPEAR III

    DTIC Science & Technology

    1994-03-01

    writing of this paper would not have been possible. I would also like to express appreciation to John Antoniades, Paul Rodriguez, Carl Seifring, and...Committee. Washington D.C.: American Physical Society, 1987. pp. 21-22. 2Ibid. ’Pake, pp. 23-34. 4Ibid. ’ Neubert , T., Mandell, M. J., Sasaki, S...experiment high-voltage effects on space charging in the ionosphere," IEEE Transactions on Nuclear Science. 35(6). December 6, 1988. p. 1386. ’ Neubert , pp

  8. Determination of SPEAR-1 Rocket Body Potential during High-Voltage Experiments

    DTIC Science & Technology

    1990-06-01

    California at San Diego La Jolla, CA 92093 10 . Dr. C. E. McIlwain Center for Astrophysics and Space Science University of California at San Diego La Jolla...Postgraduate School 39 Naval Postgraduate School 6c. ADDRESS (City, S:are, and ZIP Code) 7b. ADDRESS (Ciy, State, and ZIP Code) Monterey. CA 93943-5000...Monterey. CA 93943-5000 8a. NAME OF FUNDING.SPONSORING 80. OFFICE SYMBOL 9. PROCUREMENT INSTRUMENT IDENTIFICATION NUMBER ORGANIZATION (If applicable

  9. Uncovering and Validating Toughening Mechanisms in High Performance Composites

    DTIC Science & Technology

    2015-09-17

    striated regions have similar microstructures (see Figure 44). This aligned, fiber-reinforced design of the striated region has been adapted from spearing...Page 79 / 84 “Fracture mitigation strategies in gastropod shells,” C. Salinas and D. Kisailus, Journal of Materials, 65 (4) (2013) 473-480. DOI...2014.03.022 “Fracture mitigation strategies in gastropod shells,” C. Salinas and D. Kisailus, Journal of Materials, 65 (4) (2013) 473-480. DOI: J10.1007

  10. Comparison of Nitinol Stapes Pistons with Conventional Stapes Pistons: A Cadaver Study

    DTIC Science & Technology

    2011-01-01

    Comparison of Nitinol Stapes Pistons with Conventional Stapes Pistons: A Cadaver Study Samuel A. Spear1 and James V. Crawford2 1 48th Medical Group, ENT...cited. Objective. To visually compare the Nitinol “smart” stapes prosthesis to conventional manual crimping stapes pistons in temporal bone cadaver...answer questions about each stapes piston. The answers to the survey were then recorded for analysis. Results. 8 of 9 Nitinol pistons were described as

  11. Teutoburg Forest, Little Bighorn, and Maiwand: Why Superior Military Forces Sometimes Fail

    DTIC Science & Technology

    2009-06-12

    weapons soldiers carried javelins or throwing spears called pilum, short, stabbing swords called a gladius, and usually a dagger. 40 The pilum was...Chychota, and Doc Gabel. Without the guidance of my chair Lou DiMarco I would have floundered aimlessly long ago, and I appreciate all of his insight...combatants, and the tactics used. Yet all three battles are cases where the more powerful, technologically advanced side lost to a more primitive

  12. The Military’s Role in Enabling Political Transformation: a Catalyst for Change from Republic to Empire

    DTIC Science & Technology

    2008-06-13

    shield (hoplon) and spear in favor of the long shield (scutum), throwing javelin (pilum), and short-sword (gladius). By the second Century B.C...would like to acknowledge Dr. Terry Beckenbaugh for his thorough review and guidance as to disciplined historiography. All of the above-mentioned...fundamentally changed from ones compos of free-landed citizen soldiers to armies of professional soldiers drawn from all segments of a society. This

  13. Prompt Global Strike: China and the Spear

    DTIC Science & Technology

    2014-04-01

    longer range systems that are embedded in a larger system of advanced C4ISR is also evidenced by studies that detail China’s long-range hypersonic...to view U.S. PGS as a threat to Beijing’s conventional and nuclear weapons systems , as well as its command and control centers. With the breadth of...U.S. platforms defined as PGS-related systems in China, its analysts have not ruled out their delivery of nuclear weapons. Despite its criticism of

  14. Determination of carotenoids in spear shrimp shells (Parapenaeopsis hardwickii) by liquid chromatography.

    PubMed

    Lin, Wan-Chin; Chien, John-Tung; Chen, Bing-Huei

    2005-06-29

    The objectives of this study were to develop a high-performance liquid chromatography method for analysis of carotenoids in spear shrimp shells (Parapenaeopsis hardwickii) and to compare the extraction efficiency of carotenoids by supercritical carbon dioxide (SCD) and solvents. Results showed that the most appropriate HPLC method was accomplished by employing a Cosmosil 5C18-AR-II column and a mobile phase of methanol-dichloromethane-acetonitrile (90:5:5, v/v/v) (A) and water (100%) (B) with the following gradient elution: 92% A and 8% B in the beginning, decreased to 4% B in 9.5 min, 1% B in 26 min, 0% B in 35 min, maintained for 25 min, and returned to 92% A and 8% B in 61 min. All-trans-astaxanthin and its two cis isomers, as well as five astaxanthin monoesters and 11 diesters were resolved within 60 min with a flow rate at 2 mL/min and detection at 480 nm. Astaxanthin diesters were found to contain 12 fatty acids, of which palmitic acid and stearic acid constituted a large portion, whereas astaxanthin monoesters were found to contain 10 fatty acids with arachidonic acid dominating. Solvent extraction could generate a higher content of trans-astaxanthin and astaxanthin esters, while SCD extraction could produce greater levels of 9-cis-astaxanthin and 13-cis-astaxanthin.

  15. Acoustically-Enhanced Direct Contact Vapor Bubble Condensation

    NASA Astrophysics Data System (ADS)

    Boziuk, Thomas; Smith, Marc; Glezer, Ari

    2017-11-01

    Rate-limited, direct contact vapor condensation of vapor bubbles that are formed by direct steam injection through a nozzle in a quiescent subcooled liquid bath is accelerated using ultrasonic (MHz-range) actuation. A submerged, low power actuator produces an acoustic beam whose radiation pressure deforms the liquid-vapor interface, leading to the formation of a liquid spear that penetrates the vapor bubble to form a vapor torus with a significantly larger surface area and condensation rate. Ultrasonic focusing along the spear leads to the ejection of small, subcooled droplets through the vapor volume that impact the vapor-liquid interface and further enhance the condensation. High-speed Schlieren imaging of the formation and collapse of the vapor bubbles in the absence and presence of actuation shows that the impulse associated with the collapse of the toroidal volume leads to the formation of a turbulent vortex ring in the liquid phase. Liquid motions near the condensing vapor volume are investigated in the absence and presence of acoustic actuation using high-magnification PIV and show the evolution of a liquid jet through the center of the condensing toroidal volume and the formation and advection of vortex ring structures whose impulse appear to increase with temperature difference between the liquid and vapor phases. High-speed image processing is used to assess the effect of the actuation on the temporal and spatial variations in the characteristic scales and condensation rates of the vapor bubbles.

  16. A transect through the base of the Bronson Hill Terrane in western New Hampshire

    USGS Publications Warehouse

    Walsh, Gregory J.; Valley, Peter M.; Sicard, Karri R.; Thompson, Thelma Barton; Thompson, Peter J.

    2012-01-01

    This trip will present the preliminary results of ongoing bedrock mapping in the North Hartland and Claremont North 7.5-minute quadrangles in western New Hampshire. The trip will travel from the Lebanon pluton to just north of the Sugar River pluton (Fig. 1) with the aim of examining the lower structural levels of the Bronson Hill anticlinorium (BHA), and the nature of the boundary with the rocks of the Connecticut Valley trough (CVT). Spear and others (2002, 2003, 2008) proposed that western New Hampshire was characterized by five major faults bounding five structural levels including, from lowest to highest, the “chicken yard line”, Western New Hampshire Boundary Thrust, Skitchewaug nappe, Fall Mountain nappe, and Chesham Pond nappe. Lyons and others (1996, 1997) showed the lowest level cored by the Cornish nappe and floored by the Monroe fault. Thompson and others (1968) explained the geometry of units by folding without major thrust faults, and described the second level as the Skitchewaug nappe. This trip will focus on the two lowest levels which we have revised to call the Monroe and Skitchewaug Mountain thrust sheets. Despite decades of geologic mapping in the northeastern United States at various scales, little 1:24,000-scale (or larger scale) modern bedrock mapping has been published for the state of New Hampshire. In fact, of the New England states, New Hampshire contains the fewest published, modern bedrock geologic maps. Conversely, adjacent Vermont has a relatively high percentage of modern bedrock maps due to focused efforts to create a new state-wide bedrock geologic map over the last few decades. The new Vermont map (Ratcliffe and others, 2011) has identified considerable gaps in our knowledge of the bedrock geology in adjacent New Hampshire where published maps are, in places, more than 50 years old and at scales ranging from 1:62,500 to 1:250,000. Fundamental questions remain concerning the geology across the Connecticut River, especially in regards to the stratigraphy of the BHA and CVT, and the distribution, or even existence, of faults ranging in age from Devonian to Mesozoic (e.g., Spear and others, 2008; McWilliams and others, 2010; Walsh and others, 2010). Questions to ponder on this trip include, but are not limited to: 1) Is the Bronson Hill anticlinorium allochthonous? 2) What is the crust beneath the Bronson Hill anticlinorium? 3) Is there a “Big Staurolite nappe” as proposed by Spear and others (2002, 2003, 2008)? 4) What is the role of Taconic, Acadian, and Alleghanian orogenesis in the tectonic development of the region? Modern 1:24,000-scale mapping is the first step towards answering these questions. Mapping will be supplemented by modern geochronology and geochemistry as this project develops. We plan to share some of our provisional results during this field trip.

  17. FAR-ULTRAVIOLET OBSERVATION OF THE AQUILA RIFT WITH FIMS/SPEAR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, S.-J.; Min, K.-W.; Seon, K.-I.

    2012-07-20

    We present the results of far ultraviolet (FUV) observations of the broad region around the Aquila Rift including the Galactic plane. As compared with various wavelength data sets, dust scattering is found to be the major origin of the diffuse FUV continuum in this region. The FUV intensity clearly correlates with the dust extinction level for E(B - V) < 0.2, while this correlation disappears for E(B - V) > 0.2 due to heavy dust extinction combined with the effect of nonuniform interstellar radiation fields. The FUV intensity also correlates well with H{alpha} intensity, implying that at least some fractionmore » of the observed H{alpha} emission could be the dust-scattered light of H{alpha} photons originating elsewhere in the Galaxy. Most of the Aquila Rift region is seen devoid of diffuse FUV continuum due to heavy extinction while strong emission is observed in the surrounding regions. Molecular hydrogen fluorescent emission lines are clearly seen in the spectrum of 'Aquila-Serpens', while 'Aquila-East' does not show any apparent line features. CO emission intensity is also found to be higher in the 'Aquila-Serpens' region than in the 'Aquila-East' region. In this regard, we note that regions of star formation have been found in 'Aquila-Serpens' but not in 'Aquila-East'.« less

  18. KSC-07pd0881

    NASA Image and Video Library

    2007-04-11

    KENNEDY SPACE CENTER, FLA. -- A female anhinga roosts in branches near the water. Anhingas can be found in freshwater ponds and swamps where there is thick vegetation and tall trees. Male anhingas are black and gray; females are distinguished by a buff-colored neck and breast. When anhingas are in their breeding plumage they have a blue ring around their eyes, as seen here. The female lays three to five light blue eggs. The nest is in a tree and it is made of sticks and lined with leaves. The chicks hatch in about a month. Anhingas breed off the Gulf Coast and the Atlantic Coast from North Carolina to Texas and in the Mississippi Valley north to Kentucky and Missouri. They winter along the Gulf Coast north to North Carolina. The anhinga diet is primarily fish. Using their sharp bills, anhingas spear the fish, flip them in the air and swallow them head-first. KSC shares a boundary with the Merritt Island Wildlife Nature Refuge. The refuge is a habitat for more than 310 species of birds, 25 mammals, 117 fishes and 65 amphibians and reptiles. In addition, the Refuge supports 19 endangered or threatened wildlife species on Federal or State lists, more than any other single refuge in the U.S. Photo credit: NASA/Dimitri Gerondidakis

  19. Multiwaveguide implantable probe for light delivery to sets of distributed brain targets.

    PubMed

    Zorzos, Anthony N; Boyden, Edward S; Fonstad, Clifton G

    2010-12-15

    Optical fibers are commonly inserted into living tissues such as the brain in order to deliver light to deep targets for neuroscientific and neuroengineering applications such as optogenetics, in which light is used to activate or silence neurons expressing specific photosensitive proteins. However, an optical fiber is limited to delivering light to a single target within the three-dimensional structure of the brain. We here demonstrate a multiwaveguide probe capable of independently delivering light to multiple targets along the probe axis, thus enabling versatile optical control of sets of distributed brain targets. The 1.45-cm-long probe is microfabricated in the form of a 360-μm-wide array of 12 parallel silicon oxynitride (SiON) multimode waveguides clad with SiO(2) and coated with aluminum; probes of custom dimensions are easily created as well. The waveguide array accepts light from a set of sources at the input end and guides the light down each waveguide to an aluminum corner mirror that efficiently deflects light away from the probe axis. Light losses at each stage are small (input coupling loss, 0.4 ± 0.3 dB; bend loss, negligible; propagation loss, 3.1 ± 1 dB/cm using the outscattering method and 3.2 ± 0.4 dB/cm using the cutback method; corner mirror loss, 1.5 ± 0.4 dB); a waveguide coupled, for example, to a 5 mW source will deliver over 1.5 mW to a target at a depth of 1 cm.

  20. LED intense headband light source for fingerprint analysis

    DOEpatents

    Villa-Aleman, Eliel

    2005-03-08

    A portable, lightweight and high-intensity light source for detecting and analyzing fingerprints during field investigation. On-site field analysis requires long hours of mobile analysis. In one embodiment, the present invention comprises a plurality of light emitting diodes; a power source; and a personal attachment means; wherein the light emitting diodes are powered by the power source, and wherein the power source and the light emitting diodes are attached to the personal attachment means to produce a personal light source for on-site analysis of latent fingerprints. The present invention is available for other applications as well.

  1. Integration of organic LEDs with inorganic LEDs for a hybrid lighting system

    NASA Astrophysics Data System (ADS)

    Kong, H. J.; Park, J. W.; Kim, Y. M.

    2013-01-01

    We demonstrate that a surface-emitting hybrid light source can be realized by a combination of organic and inorganic light-emitting devices (LEDs). To this end, a blue inorganic LED bar is deployed at one side of a transparent light guide plate (LGP), and a yellow organic LED (OLED) is in contact with the rear surface of the LGP. In such a configuration, it is found that the overall luminance is almost equivalent to the sum of the luminances measured from each light source, and the overall luminance uniformity is determined mainly by the luminance uniformity of the OLED panel at high luminances. We have achieved a white color showing the Commission Internationale d'Eclairage (CIE) chromaticity coordinates of (x = 0.34, y = 0.33), the power efficiency of 9.3 lm/W, the luminance uniformity of 63% at the luminance of 3100 cd m-2, the color rendering index as high as 89.3, and the correlated color temperature finely tunable within the range between 3000 and 8000 K. Such a system facilitates color tuning by adjusting their luminous intensities and hence the implementation of the emotional lighting system.

  2. Photochemical induced growth and aggregation of metal nanoparticles in diode-array spectrophotometer via excited dimethyl-sulfoxide.

    PubMed

    Zidki, Tomer; Cohen, Haim; Meyerstein, Dan

    2010-10-21

    Ag(0) and Au(0) nanoparticles suspended in dilute aqueous solutions containing (CH(3))(2)SO are photochemically unstable. The light source of a diode-array spectrophotometer induces, within less than a minute, particle growth and aggregation. The results indicate that this process is triggered by UV light absorption by the (CH(3))(2)SO.

  3. SESAME -- A light source for the Middle East

    NASA Astrophysics Data System (ADS)

    Winick, Herman

    2012-02-01

    Developed under UNESCO and modelled on CERN, SESAME (Synchrotron-light for Experimental Science and Applications in the Middle East) is an international research centre in construction in Jordan, enabling world-class research while promoting peace through scientific cooperation. Its centerpiece, a new 2.5 GeV 3rd Generation Electron Storage Ring (133m circumference, 26nm-rad emittance, 12 places for insertion devices), will provide intense light from infra-red to hard X-rays. The Council (Bahrain, Cyprus, Egypt, Iran, Israel, Jordan, Pakistan, Palestinian Authority, Turkey), provides the annual budget. Concrete shielding is complete, and a staff of 21 is installing the refurbished 0.8 GeV BESS Y I injector system, a gift from Germany. The facility can serve 25 simultaneous experiments. Beamline equipment has been provided by Daresbury (UK), the Helmholtz Assoc. (Germany), the Swiss Light Source, LURE (France), the Univ. of Liverpool, Elettra (Italy) and US labs. Jordan has contributed 3.3M, in addition to a building and land. The EU has contributed 4.8M. Commitments confirmed by Members look set to provide most of 35M needed to complete construction of the ring and 3 beamlines. A training program has been underway since 2000. See www.sesame.org.jo

  4. A transparent look at the measurement and application of colour rendering in the use of LED light sources

    NASA Astrophysics Data System (ADS)

    Leuschner, F. W.; Van Der Westhuyzen, J. G. J.

    2014-06-01

    The technology for the measurement of colour rendering and colour quality is not new, but many parameters related to this issue are currently changing. A number of standard methods were developed and are used by different specialty areas of the lighting industry. CIE 13.3 has been the accepted standard implemented by many users and used for many years. Light-emitting Diode (LED) technology moves at a rapid pace and, as this lighting source finds wider acceptance, it appears that traditional colour-rendering measurement methods produce inconsistent results. Practical application of various types of LEDs yielded results that challenged conventional thinking regarding colour measurement of light sources. Recent studies have shown that the anatomy and physiology of the human eye is more complex than formerly accepted. Therefore, the development of updated measurement methodology also forces a fresh look at functioning and colour perception of the human eye, especially with regard to LEDs. This paper includes a short description of the history and need for the measurement of colour rendering. Some of the traditional measurement methods are presented and inadequacies are discussed. The latest discoveries regarding the functioning of the human eye and the perception of colour, especially when LEDs are used as light sources, are discussed. The unique properties of LEDs when used in practical applications such as luminaires are highlighted.

  5. Exploring direct 3D interaction for full horizontal parallax light field displays using leap motion controller.

    PubMed

    Adhikarla, Vamsi Kiran; Sodnik, Jaka; Szolgay, Peter; Jakus, Grega

    2015-04-14

    This paper reports on the design and evaluation of direct 3D gesture interaction with a full horizontal parallax light field display. A light field display defines a visual scene using directional light beams emitted from multiple light sources as if they are emitted from scene points. Each scene point is rendered individually resulting in more realistic and accurate 3D visualization compared to other 3D displaying technologies. We propose an interaction setup combining the visualization of objects within the Field Of View (FOV) of a light field display and their selection through freehand gesture tracked by the Leap Motion Controller. The accuracy and usefulness of the proposed interaction setup was also evaluated in a user study with test subjects. The results of the study revealed high user preference for free hand interaction with light field display as well as relatively low cognitive demand of this technique. Further, our results also revealed some limitations and adjustments of the proposed setup to be addressed in future work.

  6. LEGO - A Class Library for Accelerator Design and Simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cai, Yunhai

    1998-11-19

    An object-oriented class library of accelerator design and simulation is designed and implemented in a simple and modular fashion. All physics of single-particle dynamics is implemented based on the Hamiltonian in the local frame of the component. Symplectic integrators are used to approximate the integration of the Hamiltonian. A differential algebra class is introduced to extract a Taylor map up to arbitrary order. Analysis of optics is done in the same way both for the linear and non-linear cases. Recently, Monte Carlo simulation of synchrotron radiation has been added into the library. The code is used to design and simulatemore » the lattices of the PEP-II and SPEAR3. And it is also used for the commissioning of the PEP-II. Some examples of how to use the library will be given.« less

  7. SESAME-A 3rd Generation Synchrotron Light Source for the Middle East

    NASA Astrophysics Data System (ADS)

    Winick, Herman

    2010-02-01

    Developed under the auspices of UNESCO and modeled on CERN, SESAME (Synchrotron-light for Experimental Science and Applications in the Middle East) is an international research center in construction in Jordan. It will enable world class research by scientists from the region, reversing the brain drain. It will also build bridges between diverse societies, contributing to a culture of peace through international cooperation in science. The centerpiece is a synchrotron light source originating from BESSY I, a gift by Germany. The upgraded machine, a 2.5 GeV 3rd Generation Light Source (133m circumference, 26nm-rad emittance and 12 places for insertion devices), will provide light from infra-red to hard X-rays, offering excellent opportunities to train local scientists and attract those working abroad to return. The SESAME Council meets twice each year and presently has nine Members (Bahrain, Cyprus, Egypt, Iran, Israel, Jordan, Pakistan, Palestinian Authority, Turkey). Members have responsibility for the project and provide the annual operations budget (1.5M US dollars in 2009, expected to rise to about 5M when operation starts in 2012-13). Jordan provided the site, building, and infrastructure. A staff of 20 is installing the 0.8 GeV BESSY I injection system. The facility will have the capacity to serve 30 or more experiments operating simultaneously. See www.sesame.org.jo )

  8. Spectral design flexibility of LED brings better life

    NASA Astrophysics Data System (ADS)

    Ou, Haiyan; Corell, Dennis; Ou, Yiyu; Poulsen, Peter B.; Dam-Hansen, Carsten; Petersen, Paul-Michael

    2012-03-01

    Light-emitting diodes (LEDs) are penetrating into the huge market of general lighting because they are energy saving and environmentally friendly. The big advantage of LED light sources, compared to traditional incandescent lamps and fluorescent light tubes, is the flexible spectral design to make white light using different color mixing schemes. The spectral design flexibility of white LED light sources will promote them for novel applications to improve the life quality of human beings. As an initial exploration to make use of the spectral design flexibility, we present an example: 'no blue' white LED light source for sufferers of disease Porphyria. An LED light source prototype, made of high brightness commercial LEDs applying an optical filter, was tested by a patient suffering from Porphyria. Preliminary results have shown that the sufferer could withstand the light source for much longer time than the standard light source. At last future perspectives on spectral design flexibility of LED light sources improving human being's life will be discussed, with focus on the light and health. The good health is ensured by the spectrum optimized so that vital hormones (melatonin and serotonin) are produced during times when they support human daily rhythm.

  9. Compact RGBY light sources with high luminance for laser display applications

    NASA Astrophysics Data System (ADS)

    Paschke, Katrin; Blume, Gunnar; Werner, Nils; Müller, André; Sumpf, Bernd; Pohl, Johannes; Feise, David; Ressel, Peter; Sahm, Alexander; Bege, Roland; Hofmann, Julian; Jedrzejczyk, Daniel; Tränkle, Günther

    2018-02-01

    Watt-class visible laser light with a high luminance can be created with high-power GaAs-based lasers either directly in the red spectral region or using single-pass second harmonic generation (SHG) for the colors in the blue-yellow spectral region. The concepts and results of red- and near infrared-emitting distributed Bragg reflector tapered lasers and master oscillator power amplifier systems as well as their application for SHG bench-top experiments and miniaturized modules are presented. Examples of these high-luminance light sources aiming at different applications such as flying spot display or holographic 3D cinema are discussed in more detail. The semiconductor material allows an easy adaptation of the wavelength allowing techniques such as six-primary color 3D projection or color space enhancement by adding a fourth yellow color.

  10. Polarimetry - Scope on the 3.6-m Devasthal Optical Telescope

    NASA Astrophysics Data System (ADS)

    Joshi, Umesh Chandra; Ganesh, Shashikiran; Baliyan, Kiran Singh

    2018-04-01

    Polarization measurements are very helpful to understand the nature of some of the stellar and extra-galactic sources. Light from astronomical objects is in general polarized to some degree and its measurement gives additional information related to the magnetic field, the distribution of scattering material, the non-thermal nature of light, etc. Since the degree of polarization in the majority of astronomical sources is 1-5%, and polarimetry requires additional optics with respect to classical imaging, these measurements require much more photons to achieve a good signal-to-noise ratio for which the 3.6-m Devasthal Optical Telescope (DOT) facility is suitable.

  11. Blue-light-induced PIN3 polarization for root negative phototropic response in Arabidopsis.

    PubMed

    Zhang, Kun-Xiao; Xu, Heng-Hao; Yuan, Ting-Ting; Zhang, Liang; Lu, Ying-Tang

    2013-10-01

    Root negative phototropism is an important response in plants. Although blue light is known to mediate this response, the cellular and molecular mechanisms underlying root negative phototropism remain unclear. Here, we report that the auxin efflux carrier PIN-FORMED (PIN) 3 is involved in asymmetric auxin distribution and root negative phototropism. Unilateral blue-light illumination polarized PIN3 to the outer lateral membrane of columella cells at the illuminated root side, and increased auxin activity at the illuminated side of roots, where auxin promotes growth and causes roots bending away from the light source. Furthermore, root negative phototropic response and blue-light-induced PIN3 polarization were modulated by a brefeldin A-sensitive, GNOM-dependent, trafficking pathway and by phot1-regulated PINOID (PID)/PROTEIN PHOSPHATASE 2A (PP2A) activity. Our results indicate that blue-light-induced PIN3 polarization is needed for asymmetric auxin distribution during root negative phototropic response. © 2013 The Authors The Plant Journal © 2013 John Wiley & Sons Ltd.

  12. Visible-light-driven N-TiO2@SiO2@Fe3O4 magnetic nanophotocatalysts: Synthesis, characterization, and photocatalytic degradation of PPCPs.

    PubMed

    Kumar, Ashutosh; Khan, Musharib; Fang, Liping; Lo, Irene M C

    2017-07-24

    TiO 2 -based photocatalysis offers certain advantages like rapid degradation and mineralization of organic compounds. However, the practical applicability of photocatalysts in degradation of pharmaceuticals and personal care products (PPCPs) is still restricted by challenges including their limited photocatalytic activity under visible light and difficulty in their separation from suspension. To overcome these challenges, a visible-light-driven magnetic N-TiO 2 @SiO 2 @Fe 3 O 4 nanophotocatalyst was developed through fine-tuning the pertinent factors (calcination temperature, Fe 3 O 4 loading, and nitrogen doping) involved during synthesis process, on the basis of degradation of ibuprofen (a typical PPCP). The TEM-EDX, XRD and XPS analyses confirmed the successful synthesis of nanophotocatalyst. By comparing nanophotocatalyst's performance on ibuprofen under two visible light sources, i.e., compact fluorescent lamps (CFLs) and light emitting diodes (LEDs) of similar irradiance, CFLs of irradiance 320μWcm -2 and peak emissive wavelength 543nm served as a better source, resulting in 94% degradation. Furthermore, 93% of benzophenone-3 within 5h and 71% of carbamazepine within 9h was degraded under visible light emitted by CFLs. The superparamagnetic behavior of the nanophotocatalyst enabled its successful magnetic separation (95% efficiency) from the suspension within 20-25min under an electromagnetic field of ∼200mT. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Light distribution modulated diffuse reflectance spectroscopy.

    PubMed

    Huang, Pin-Yuan; Chien, Chun-Yu; Sheu, Chia-Rong; Chen, Yu-Wen; Tseng, Sheng-Hao

    2016-06-01

    Typically, a diffuse reflectance spectroscopy (DRS) system employing a continuous wave light source would need to acquire diffuse reflectances measured at multiple source-detector separations for determining the absorption and reduced scattering coefficients of turbid samples. This results in a multi-fiber probe structure and an indefinite probing depth. Here we present a novel DRS method that can utilize a few diffuse reflectances measured at one source-detector separation for recovering the optical properties of samples. The core of innovation is a liquid crystal (LC) cell whose scattering property can be modulated by the bias voltage. By placing the LC cell between the light source and the sample, the spatial distribution of light in the sample can be varied as the scattering property of the LC cell modulated by the bias voltage, and this would induce intensity variation of the collected diffuse reflectance. From a series of Monte Carlo simulations and phantom measurements, we found that this new light distribution modulated DRS (LDM DRS) system was capable of accurately recover the absorption and scattering coefficients of turbid samples and its probing depth only varied by less than 3% over the full bias voltage variation range. Our results suggest that this LDM DRS platform could be developed to various low-cost, efficient, and compact systems for in-vivo superficial tissue investigation.

  14. Light distribution modulated diffuse reflectance spectroscopy

    PubMed Central

    Huang, Pin-Yuan; Chien, Chun-Yu; Sheu, Chia-Rong; Chen, Yu-Wen; Tseng, Sheng-Hao

    2016-01-01

    Typically, a diffuse reflectance spectroscopy (DRS) system employing a continuous wave light source would need to acquire diffuse reflectances measured at multiple source-detector separations for determining the absorption and reduced scattering coefficients of turbid samples. This results in a multi-fiber probe structure and an indefinite probing depth. Here we present a novel DRS method that can utilize a few diffuse reflectances measured at one source-detector separation for recovering the optical properties of samples. The core of innovation is a liquid crystal (LC) cell whose scattering property can be modulated by the bias voltage. By placing the LC cell between the light source and the sample, the spatial distribution of light in the sample can be varied as the scattering property of the LC cell modulated by the bias voltage, and this would induce intensity variation of the collected diffuse reflectance. From a series of Monte Carlo simulations and phantom measurements, we found that this new light distribution modulated DRS (LDM DRS) system was capable of accurately recover the absorption and scattering coefficients of turbid samples and its probing depth only varied by less than 3% over the full bias voltage variation range. Our results suggest that this LDM DRS platform could be developed to various low-cost, efficient, and compact systems for in-vivo superficial tissue investigation. PMID:27375931

  15. Light Emitting Diode Flashlights as Effective and Inexpensive Light Sources for Fluorescence Microscopy

    PubMed Central

    Robertson, J. Brian; Zhang, Yunfei; Johnson, Carl Hirschie

    2009-01-01

    Summary Light-emitting diodes (LEDs) are becoming more commonly used as light sources for fluorescence microscopy. We describe the adaptation of a commercially available LED flashlight for use as a source for fluorescence excitation. This light source is long-lived, inexpensive, and is effective for excitation in the range of 440–600 nm. PMID:19772530

  16. Light intensity and quality from sole-source light-emitting diodes impact growth, morphology, and nutrient content of Brassica microgreens

    USDA-ARS?s Scientific Manuscript database

    Multi-layer vertical production systems using sole-source (SS) lighting can be used for microgreen production; however, traditional SS lighting can consume large amounts of electrical energy. Light-emitting diodes (LEDs) offer many advantages over conventional light sources including: high photoelec...

  17. Light sources and output couplers for a backlight with switchable emission angles

    NASA Astrophysics Data System (ADS)

    Fujieda, Ichiro; Imai, Keita; Takagi, Yoshihiko

    2007-09-01

    For switching viewing angles of a liquid crystal display, we proposed to place a liquid crystal device between an LED and a light-guide of a backlight. The first key component for this configuration is a light source with electronically-controlled emission angles. Here, we construct such a device by stacking an optical film and a polymer-network liquid crystal (PNLC) cell on top of a chip-type LED. The optical film contains opaque parallel plates that limit the LED output in a narrow angular range. The PNLC cell either transmits or scatters the light emerging from the optical film. Experiment using a 15μm-thick PNLC cell shows that the angular distribution becomes 2.3 times wider by turning off the PNLC cell. We place this light source at one end of a light-guide so that the angular distribution of the light propagating inside is controlled. The second key component is some types of micro-strucrures built on the light-guide to out-couple the propagating light. We first attached various optical films on a light-guide surface. Although the angular distribution of the extracted light was switched successfully, light was mostly emitted into an oblique direction, approximately 60° from the plane normal. Next, we used a half-cylinder in place of the optical films. The curved surface of the cylinder was attached to the light-guide with a small amount of matching oil, which constituted an optical window. We measured that the angular distribution of the extracted light decreased to 35° FWHM from 62° FWHM by turning on the PNLC cell.

  18. LED lamp

    DOEpatents

    Galvez, Miguel; Grossman, Kenneth; Betts, David

    2013-11-12

    There is herein described a lamp for providing white light comprising a plurality of light sources positioned on a substrate. Each of said light sources comprises a blue light emitting diode (LED) and a dome that substantially covers said LED. A first portion of said blue light from said LEDs is transmitted through said domes and a second portion of said blue light is converted into a red light by a first phosphor contained in said domes. A cover is disposed over all of said light sources that transmits at least a portion of said red and blue light emitted by said light sources. The cover contains a second phosphor that emits a yellow light in response to said blue light. The red, blue and yellow light combining to form the white light and the white light having a color rendering index (CRI) of at least about 80.

  19. Photonic crystal light source

    DOEpatents

    Fleming, James G [Albuquerque, NM; Lin, Shawn-Yu [Albuquerque, NM; Bur, James A [Corrales, NM

    2004-07-27

    A light source is provided by a photonic crystal having an enhanced photonic density-of-states over a band of frequencies and wherein at least one of the dielectric materials of the photonic crystal has a complex dielectric constant, thereby producing enhanced light emission at the band of frequencies when the photonic crystal is heated. The dielectric material can be a metal, such as tungsten. The spectral properties of the light source can be easily tuned by modification of the photonic crystal structure and materials. The photonic crystal light source can be heated electrically or other heating means. The light source can further include additional photonic crystals that exhibit enhanced light emission at a different band of frequencies to provide for color mixing. The photonic crystal light source may have applications in optical telecommunications, information displays, energy conversion, sensors, and other optical applications.

  20. Energy cost unit of street and park lighting system with solar technology for a more friendly city

    NASA Astrophysics Data System (ADS)

    Warman, E.; Nasution, F. S.; Fahmi, F.

    2018-03-01

    Street and park lighting system is part of a basic infrastructure need to be available in such a friendly city. Enough light will provide more comfort to citizens, especially at night since its function to illuminate roads and park environments around the covered area. The necessity to add more and more lighting around the city caused the rapid growth of the street and park lighting system while the power from PLN (national electricity company) is insufficient and the cost is getting higher. Therefore, it is necessary to consider other energy sources that are economical, environmentally friendly with good continuity. Indonesia, which located on the equator, have benefited from getting solar radiation throughout the year. This free solar radiation can be utilized as an energy source converted by solar cells to empower street and park lighting system. In this study, we planned the street and park lighting with solar technology as alternatives. It was found that for Kota Medan itself, an average solar radiation intensity of 3,454.17 Wh / m2 / day is available. By using prediction and projection method, it was calculated that the energy cost unit for this system was at Rp 3,455.19 per kWh. This cost was higher than normal energy cost unit but can answer the scarcity of energy availability for street and park lighting system

  1. A compact, coherent light source system architecture

    NASA Astrophysics Data System (ADS)

    Biedron, S. G.; Dattoli, G.; DiPalma, E.; Einstein, J.; Milton, S. V.; Petrillo, V.; Rau, J. V.; Sabia, E.; Spassovsky, I. P.; van der Slot, P. J. M.

    2016-09-01

    Our team has been examining several architectures for short-wavelength, coherent light sources. We are presently exploring the use and role of advanced, high-peak power lasers for both accelerating the electrons and generating a compact light source with the same laser. Our overall goal is to devise light sources that are more accessible by industry and in smaller laboratory settings. Although we cannot and do not want to compete directly with sources such as third-generation light sources or that of national-laboratory-based free-electron lasers, we have several interesting schemes that could bring useful and more coherent, short-wavelength light source to more researchers. Here, we present and discuss several results of recent simulations and our future steps for such dissemination.

  2. Intense X-ray and EUV light source

    DOEpatents

    Coleman, Joshua; Ekdahl, Carl; Oertel, John

    2017-06-20

    An intense X-ray or EUV light source may be driven by the Smith-Purcell effect. The intense light source may utilize intense electron beams and Bragg crystals. This may allow the intense light source to range from the extreme UV range up to the hard X-ray range.

  3. Carambola optics for recycling of light.

    PubMed

    Leutz, Ralf; Fu, Ling; Ries, Harald

    2006-04-20

    Recycling of light allows the luminance (radiance) emitted by a light source to be increased at the cost of reducing the total luminous flux (radiant power). Recycling of light means returning part of the emitted light to the source, where part of it will escape absorption. An optical design that is suitable for multiple and controlled recycling is described. Carambola optics is named for its resemblance to star fruit. Several pairs of mirrors or prisms redirect light repeatedly onto the source, thus achieving multiple transits of the light through the source. This recycled light exits the carambola in the same phase space as light directly emitted and not recycled.

  4. Fiber-optic voltage sensor with cladded fiber and evanescent wave variation detection

    DOEpatents

    Wood, C.B.

    1992-12-15

    A fiber optic voltage sensor is described which includes a source of light, a reference fiber for receiving a known percentage of the light and an electrostrictive element having terminals across which is applied, a voltage to be measured. The electrostrictive element is responsive to the applied voltage to assume an altered physical state. A measuring fiber also receives a known percentage of light from the light source and is secured about the electrostrictive element. The measuring fiber is provided with a cladding and exhibits an evanescent wave in the cladding. The measuring fiber has a known length which is altered when the electrostrictive element assumes its altered physical state. A differential sensor is provided which senses the intensity of light in both the reference fiber and the measuring fiber and provides an output indicative of the difference between the intensities. 3 figs.

  5. Photoresponse in La0.9Hf0.1MnO3/0.05wt%Nb-doped SrTiO3 heteroepitaxial junctions

    NASA Astrophysics Data System (ADS)

    Qi, Yaping; Ni, Hao; Zheng, Ming; Zeng, Jiali; Jiang, Yucheng; Gao, Ju

    2018-05-01

    Excellent photo detectors need to have the rapid response and good repeatability from the requirement of industrial applications. In this paper, transport behavior and opto-response of heterostructures made with La0.9Hf0.1MnO3 and 0.05wt%Nb-doped SrTiO3 were investigated. The heterojunctions exhibited an excellent rectifying feature with very low leakage in a broad temperature region (from 40 to 300 K). These thin films presented persistent and stable photovoltages upon light illumination. Rapid shift between small and large voltages corresponding to "light OFF" and "light ON" states, respectively, was observed, demonstrating reliable photo detection behavior. A semiconductor laser with a wavelength of 650 nm was used as the light source. It is also noted that the observed photovoltages are strongly determined by light intensity. The injection of photoexcited charge carriers (electrons) could be responsible for the appearance of the observed opto-response. Such manipulative features by light irradiation exhibit great potential for light detectors for visible light.

  6. Omega Dante Soft X-Ray Power Diagnostic Component Calibration at the National Synchrotron Light Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, K; Weber, F; Dewald, E

    2004-04-15

    The Dante soft x-ray spectrometer installed on the Omega laser facility at the Laboratory for Laser Energetics, University of Rochester is a twelve-channel filter-edge defined x-ray power diagnostic. It is used to measure the absolute flux from direct drive, indirect drive (hohlraums) and other plasma sources. Calibration efforts using two beam lines, U3C (50eV-1keV) and X8A (1keV-6keV) at the National Synchrotron Light Source (NSLS) have been implemented to insure the accuracy of these measurements. We have calibrated vacuum x-ray diodes, mirrors and filters.

  7. People can understand descriptions of motion without activating visual motion brain regions

    PubMed Central

    Dravida, Swethasri; Saxe, Rebecca; Bedny, Marina

    2013-01-01

    What is the relationship between our perceptual and linguistic neural representations of the same event? We approached this question by asking whether visual perception of motion and understanding linguistic depictions of motion rely on the same neural architecture. The same group of participants took part in two language tasks and one visual task. In task 1, participants made semantic similarity judgments with high motion (e.g., “to bounce”) and low motion (e.g., “to look”) words. In task 2, participants made plausibility judgments for passages describing movement (“A centaur hurled a spear … ”) or cognitive events (“A gentleman loved cheese …”). Task 3 was a visual motion localizer in which participants viewed animations of point-light walkers, randomly moving dots, and stationary dots changing in luminance. Based on the visual motion localizer we identified classic visual motion areas of the temporal (MT/MST and STS) and parietal cortex (inferior and superior parietal lobules). We find that these visual cortical areas are largely distinct from neural responses to linguistic depictions of motion. Motion words did not activate any part of the visual motion system. Motion passages produced a small response in the right superior parietal lobule, but none of the temporal motion regions. These results suggest that (1) as compared to words, rich language stimuli such as passages are more likely to evoke mental imagery and more likely to affect perceptual circuits and (2) effects of language on the visual system are more likely in secondary perceptual areas as compared to early sensory areas. We conclude that language and visual perception constitute distinct but interacting systems. PMID:24009592

  8. Lighting system with thermal management system

    DOEpatents

    Arik, Mehmet; Weaver, Stanton Earl; Stecher, Thomas Elliot; Seeley, Charles Erklin; Kuenzler, Glenn Howard; Wolfe, Jr., Charles Franklin; Utturkar, Yogen Vishwas; Sharma, Rajdeep; Prabhakaran, Satish; Icoz, Tunc

    2015-02-24

    Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system is configured to provide an air flow, such as a unidirectional air flow, through the housing structure in order to cool the light source. The driver electronics are configured to provide power to each of the light source and the thermal management system.

  9. Lighting system with thermal management system

    DOEpatents

    Arik, Mehmet; Weaver, Stanton Earl; Stecher, Thomas Elliot; Seeley, Charles Erklin; Kuenzler, Glenn Howard; Wolfe, Jr., Charles Franklin; Utturkar, Yogen Vishwas; Sharma, Rajdeep; Prabhakaran, Satish; Icoz, Tunc

    2015-08-25

    Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system is configured to provide an air flow, such as a unidirectional air flow, through the housing structure in order to cool the light source. The driver electronics are configured to provide power to each of the light source and the thermal management system.

  10. Lighting system with thermal management system

    DOEpatents

    Arik, Mehmet; Weaver, Stanton; Stecher, Thomas; Seeley, Charles; Kuenzler, Glenn; Wolfe, Jr., Charles; Utturkar, Yogen; Sharma, Rajdeep; Prabhakaran, Satish; Icoz, Tunc

    2013-05-07

    Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system is configured to provide an air flow, such as a unidirectional air flow, through the housing structure in order to cool the light source. The driver electronics are configured to provide power to each of the light source and the thermal management system.

  11. Lighting system with thermal management system

    DOEpatents

    Arik, Mehmet; Weaver, Stanton Earl; Stecher, Thomas Elliot; Seeley, Charles Erklin; Kuenzler, Glenn Howard; Wolfe, Jr, Charles Franklin; Utturkar, Yogen Vishwas; Sharma, Rajdeep; Prabhakaran, Satish; Icoz, Tunc

    2016-10-11

    Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system is configured to provide an air flow, such as a unidirectional air flow, through the housing structure in order to cool the light source. The driver electronics are configured to provide power to each of the light source and the thermal management system.

  12. Study of optical design of three-dimensional digital ophthalmoscopes.

    PubMed

    Fang, Yi-Chin; Yen, Chih-Ta; Chu, Chin-Hsien

    2015-10-01

    This study primarily involves using optical zoom structures to design a three-dimensional (3D) human-eye optical sensory system with infrared and visible light. According to experimental data on two-dimensional (2D) and 3D images, human-eye recognition of 3D images is substantially higher (approximately 13.182%) than that of 2D images. Thus, 3D images are more effective than 2D images when they are used at work or in high-recognition devices. In the optical system design, infrared and visible light wavebands were incorporated as light sources to perform simulations. The results can be used to facilitate the design of optical systems suitable for 3D digital ophthalmoscopes.

  13. Assessment of the actual light dose in photodynamic therapy.

    PubMed

    Schaberle, Fabio A

    2018-06-09

    Photodynamic therapy (PDT) initiates with the absorption of light, which depends on the spectral overlap between the light source emission and the photosensitizer absorption, resulting in the number of photons absorbed, the key parameter starting PDT processes. Most papers report light doses regardless if the light is only partially absorbed or shifted relatively to the absorption peak, misleading the actual light dose value and not allowing quantitative comparisons between photosensitizers and light sources. In this manuscript a method is presented to calculate the actual light dose delivered by any light source for a given photosensitizer. This method allows comparing light doses delivered for any combination of light source (broad or narrow band or daylight) and photosensitizer. Copyright © 2018. Published by Elsevier B.V.

  14. Bending the Spear: The Campaign Against the Lord’s Resistance Army

    DTIC Science & Technology

    2017-12-01

    cleansing rituals alone. When people were killed, he purified them by himself.65 New members had to undertake rites of passage to be cleansed of witchcraft...of faith in his spiritual powers , and so would abduct UPDA soldiers and force them into the LRA when he encountered them away from their units.70...against Kony. Kony wanted to start an Acholi war. He wanted a Luo republic, wanted it to go to the Nile. People turned against him. When they said

  15. Effects of Different Distributions of Training Time on the Acquisition of Contact Flying Skills

    DTIC Science & Technology

    1981-07-01

    evaluate their own performance. PERCEPTION OF TRAINING. Based orn their general response to the Student Opinion Survey, the students in both programs felt...analy- sis. Dr. Jerry M. Childs and Mr. Edward Miller of Seville aided in the devel- oment of the pilot performance measurement instruments. Mr. E. Peter...J. B., Childs , J. M., Prophet, W. W., & Spears, W. L. Human factors problems in general aviation (Tech. Rep. FAA-CT-80-194). Washington, DC: Federal

  16. Cultural Resources Evaluation of Portions of the Aloha-Rigolette Area, Louisiana Flood Control Project, Grant Parish, Louisiana

    DTIC Science & Technology

    1992-11-01

    OF ENGINEERS P.O. BOX 60267 NEW ORLEANS. LOUISIANA 70160-0267 REPLY TO ATTENTIONOF: May 5, 1992 Planning Division Environmental Analysis Branch To The...tools used for exploiting botanical as well as faunal resources. This includes mortars, pestles , and mealing stones (Rue 1990). The atlatl, or spear...included the J.A. Bently Lumber Co., Urania Lumber Co., Bodcaw Lumber Co., and Industrial Lumber Co. The expansion of the lumber industry directly related

  17. Cultural Resources Survey, Harry S. Truman Dam and Reservoir Project, Missouri. Volume 5. Lithic and Ceramic Studies.

    DTIC Science & Technology

    1983-02-01

    wash it out and mix it with grease or other media . Heated over char- coal, red ochre takes on a brighter color; the washing removes dulling impurities...effect of dye; they were mixed with various media for painting the wood and leather of boxes, arrows, spears, shields, tipis, robes, parfleche cases...etc. The media for applying the pigments varied. In general, face paint * was mixed with grease or saliva, while the medium for wood or skins was

  18. Study of the Power Supply Ripple Effect on teh Dynamics at SPEAR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Terebilo, A.; Pellegrini, C.; /UCLA

    For long term stability analysis time variation of tunes is important. We have proposed and tested a technique for measuring the magnitude of this variation. This was made possible by using tune extraction algorithms that require small number of turns thus giving an instantaneous tune of the machine. In this paper we demonstrate the measured effect of the tune modulation with 60 Hz power supplies ripple, power line interference from SLAC linac operating at 30 Hz repetition rate, and nonperiodic variation.

  19. Development of an ultra-compact mid-infrared attenuated total reflectance spectrophotometer

    NASA Astrophysics Data System (ADS)

    Kim, Dong Soo; Lee, Tae-Ro; Yoon, Gilwon

    2014-07-01

    Mid-infrared spectroscopy has been an important tool widely used for qualitative analysis in various fields. However, portable or personal use is size and cost prohibitive for either Fourier transform infrared or attenuated total reflectance (ATR) spectrophotometers. In this study, we developed an ultra-compact ATR spectrophotometer whose frequency band was 5.5-11.0 μm. We used miniature components, such as a light source fabricated by semiconductor technology, a linear variable filter, and a pyro-electric array detector. There were no moving parts. Optimal design based on two light sources, a zippered configuration of the array detector and ATR optics could produce absorption spectra that might be used for qualitative analysis. A microprocessor synchronized the pulsed light sources and detector, and all the signals were processed digitally. The size was 13.5×8.5×3.5 cm3 and the weight was 300 grams. Due to its low cost, our spectrophotometer can replace many online monitoring devices. Another application could be for a u-healthcare system installed in the bathroom or attached to a smartphone for monitoring substances in body fluids.

  20. Quantitative phase imaging of biological cells using spatially low and temporally high coherent light source.

    PubMed

    Ahmad, Azeem; Dubey, Vishesh; Singh, Gyanendra; Singh, Veena; Mehta, Dalip Singh

    2016-04-01

    In this Letter, we demonstrate quantitative phase imaging of biological samples, such as human red blood cells (RBCs) and onion cells using narrow temporal frequency and wide angular frequency spectrum light source. This type of light source was synthesized by the combined effect of spatial, angular, and temporal diversity of speckle reduction technique. The importance of using low spatial and high temporal coherence light source over the broad band and narrow band light source is that it does not require any dispersion compensation mechanism for biological samples. Further, it avoids the formation of speckle or spurious fringes which arises while using narrow band light source.

  1. Silurian shale origin for light oil, condensate, and gas in Algeria and the Middle East

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zumberge, J.E.; Macko, S.

    1996-01-01

    Two of the largest gas fields in the world, Hasi R'Mel, Algeria and North Dome, Qatar, also contain substantial condensate and light oil reserves. Gas to source rock geochemical correlation is difficult due to the paucity of molecular parameters in the former although stable isotope composition is invaluable. However, by correlating source rocks with light oils and condensates associated with gas production using traditional geochemical parameters such as biomarkers and isotopes, a better understanding of the origin of the gas is achieved. Much of the crude oil in the Ghadames/Illizi Basins of Algeria has long been thought to have beenmore » generated from Silurian shales. New light oil discoveries in Saudi Arabia have also been shown to originate in basal euxinic Silurian shales. Key sterane and terpane biomarkers as well as the stable carbon isotopic compositions of the C15+ saturate and aromatic hydrocarbon fractions allow for the typing of Silurian-sourced, thermally mature light oils in Algeria and the Middle East. Even though biomarkers are often absent due to advanced thermal maturity, condensates can be correlated to the light oils using (1) carbon isotopes of the residual heavy hydrocarbon fractions, (2) light hydrocarbon distributions (e.g., C7 composition), and (3) compound specific carbon isotopic composition of the light hydrocarbons. The carbon isotopes of the C2-C4 gas components ran then be compared to the associated condensate and light oil isotopic composition.« less

  2. Silurian shale origin for light oil, condensate, and gas in Algeria and the Middle East

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zumberge, J.E.; Macko, S.

    Two of the largest gas fields in the world, Hasi R`Mel, Algeria and North Dome, Qatar, also contain substantial condensate and light oil reserves. Gas to source rock geochemical correlation is difficult due to the paucity of molecular parameters in the former although stable isotope composition is invaluable. However, by correlating source rocks with light oils and condensates associated with gas production using traditional geochemical parameters such as biomarkers and isotopes, a better understanding of the origin of the gas is achieved. Much of the crude oil in the Ghadames/Illizi Basins of Algeria has long been thought to have beenmore » generated from Silurian shales. New light oil discoveries in Saudi Arabia have also been shown to originate in basal euxinic Silurian shales. Key sterane and terpane biomarkers as well as the stable carbon isotopic compositions of the C15+ saturate and aromatic hydrocarbon fractions allow for the typing of Silurian-sourced, thermally mature light oils in Algeria and the Middle East. Even though biomarkers are often absent due to advanced thermal maturity, condensates can be correlated to the light oils using (1) carbon isotopes of the residual heavy hydrocarbon fractions, (2) light hydrocarbon distributions (e.g., C7 composition), and (3) compound specific carbon isotopic composition of the light hydrocarbons. The carbon isotopes of the C2-C4 gas components ran then be compared to the associated condensate and light oil isotopic composition.« less

  3. Effect of Shade and Light Curing Mode on the Degree of Conversion of Silorane-Based and Methacrylate-Based Resin Composites.

    PubMed

    Sm, Mousavinasab; M, Atai; N, Salehi; A, Salehi

    2016-12-01

    The degree of conversion depends on the material composition, light source properties, distance from light source, light intensity, curing time, and other factors such as shade and translucency. In the present study, we evaluated the effects of different light-curing modes and shades of methacrylate and silorane-based resin composites on the degree of conversion of resin composites (DC). The methacrylate-based (Filtek Z250, 3M, ESPE) and low-shrinkage silorane-based (Filtek P90, 3M, ESPE) resin composites were used in three groups as follows: group 1-Filtek Z250 (shade A3), group 2-Filtek Z250 (shade B2), and group 3-Filtek P90 (shade A3). We used a light-emitting diode (LED) curing unit for photopolymerization. 10 samples were prepared in each group to evaluate the degree of conversion; 5 samples were cured using soft-start curing mode, and the other 5 were cured using standard curing mode. The DC of the resin composites was measured using Fourier Transform Infrared Spectroscopy (FTIR). The data were analyzed using Kruskal Wallis and one-way ANOVA statistical tests. The degree of conversion of silorane-based resin composite was 70 - 75.8% and that of methacrylate-based resin composites was 60.2 - 68.2% (p = 0.009). The degree of conversion of the composite with brighter colour (B2) was statistically more than the darker composite (A3). Higher degree of conversion was achieved applying the standard curing mode. The results of the study showed that the colour and type of the resin composite and also the curing mode influence the degree of conversion of resin composites.

  4. A novel amblyopia treatment system based on LED light source

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaoqing; Chen, Qingshan; Wang, Xiaoling

    2011-05-01

    A novel LED (light emitting diode) light source of five different colors (white, red, green, blue and yellow) is adopted instead of conventional incandescent lamps for an amblyopia treatment system and seven training methods for rectifying amblyopia are incorporated so as for achieving an integrated therapy. The LED light source is designed to provide uniform illumination, adjustable light intensity and alterable colors. Experimental tests indicate that the LED light source operates steadily and fulfills the technical demand of amblyopia treatment.

  5. A novel amblyopia treatment system based on LED light source

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaoqing; Chen, Qingshan; Wang, Xiaoling

    2010-12-01

    A novel LED (light emitting diode) light source of five different colors (white, red, green, blue and yellow) is adopted instead of conventional incandescent lamps for an amblyopia treatment system and seven training methods for rectifying amblyopia are incorporated so as for achieving an integrated therapy. The LED light source is designed to provide uniform illumination, adjustable light intensity and alterable colors. Experimental tests indicate that the LED light source operates steadily and fulfills the technical demand of amblyopia treatment.

  6. Optically controlled polarization in highly oriented ferroelectric thin films

    NASA Astrophysics Data System (ADS)

    Borkar, Hitesh; Tomar, M.; Gupta, Vinay; Katiyar, Ram S.; Scott, J. F.; Kumar, Ashok

    2017-08-01

    The out-of-plane and in-plane polarization of (Pb0.6Li0.2Bi0.2)(Zr0.2Ti0.8)O3 (PLBZT) thin film has been studied in the dark and under illumination from a weak light source of a comparable bandgap. A highly oriented PLBZT thin film was grown on a LaNiO3/LaAlO3 substrate by pulsed laser deposition; it showed well-saturated polarization which was significantly enhanced under light illumination. We employed two configurations for polarization characterization: the first deals with out-of-plane polarization with a single capacitor under investigation, whereas the second uses two capacitors connected in series via the bottom electrode. Two different configurations were illuminated using different energy sources and their effects were studied. The latter configuration shows a significant change in polarization under light illumination that may provide an extra degree of freedom for device miniaturization. The polarization was also tested using positive-up and negative-down measurements, confirming robust polarization and its switching under illumination.

  7. The Inverse-Square Law with Data Loggers

    ERIC Educational Resources Information Center

    Bates, Alan

    2013-01-01

    The inverse-square law for the intensity of light received at a distance from a light source has been verified using various experimental techniques. Typical measurements involve a manual variation of the distance between a light source and a light sensor, usually by sliding the sensor or source along a bench, measuring the source-sensor distance…

  8. Colors of attraction: Modeling insect flight to light behavior.

    PubMed

    Donners, Maurice; van Grunsven, Roy H A; Groenendijk, Dick; van Langevelde, Frank; Bikker, Jan Willem; Longcore, Travis; Veenendaal, Elmar

    2018-06-26

    Light sources attract nocturnal flying insects, but some lamps attract more insects than others. The relation between the properties of a light source and the number of attracted insects is, however, poorly understood. We developed a model to quantify the attractiveness of light sources based on the spectral output. This model is fitted using data from field experiments that compare a large number of different light sources. We validated this model using two additional datasets, one for all insects and one excluding the numerous Diptera. Our model facilitates the development and application of light sources that attract fewer insects without the need for extensive field tests and it can be used to correct for spectral composition when formulating hypotheses on the ecological impact of artificial light. In addition, we present a tool allowing the conversion of the spectral output of light sources to their relative insect attraction based on this model. © 2018 Wiley Periodicals, Inc.

  9. Geometrical analysis of an optical fiber bundle displacement sensor

    NASA Astrophysics Data System (ADS)

    Shimamoto, Atsushi; Tanaka, Kohichi

    1996-12-01

    The performance of a multifiber optical lever was geometrically analyzed by extending the Cook and Hamm model [Appl. Opt. 34, 5854-5860 (1995)] for a basic seven-fiber optical lever. The generalized relationships between sensitivity and the displacement detection limit to the fiber core radius, illumination irradiance, and coupling angle were obtained by analyses of three various types of light source, i.e., a parallel beam light source, an infinite plane light source, and a point light source. The analysis of the point light source was confirmed by a measurement that used the light source of a light-emitting diode. The sensitivity of the fiber-optic lever is inversely proportional to the fiber core radius, whereas the receiving light power is proportional to the number of illuminating and receiving fibers. Thus, the bundling of the finer fiber with the larger number of illuminating and receiving fibers is more effective for improving sensitivity and the displacement detection limit.

  10. Long Persistent Light Emitting Diode Indicators

    ERIC Educational Resources Information Center

    Jia, Dongdong; Ma, Yiwei; Hunter, D. N.

    2007-01-01

    An undergraduate laboratory was designed for undergraduate students to make long persistent light emitting diode (LED) indicators using phosphors. Blue LEDs, which emit at 465 nm, were characterized and used as an excitation source. Long persistent phosphors, SrAl[subscript 2]O[subscript 4]:Eu[superscript 2+],Dy[superscript 3+] (green) and…

  11. 40 CFR 86.884-11 - Instrument checks.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... equipment response of zero; (3) Calibrated neutral density filters having approximately 10, 20, and 40 percent opacity shall be employed to check the linearity of the instrument. The filter(s) shall be... beam of light from the light source emanates, and the recorder response shall be noted. Filters with...

  12. Two-step design method for highly compact three-dimensional freeform optical system for LED surface light source.

    PubMed

    Mao, Xianglong; Li, Hongtao; Han, Yanjun; Luo, Yi

    2014-10-20

    Designing an illumination system for a surface light source with a strict compactness requirement is quite challenging, especially for the general three-dimensional (3D) case. In accordance with the two key features of an expected illumination distribution, i.e., a well-controlled boundary and a precise illumination pattern, a two-step design method is proposed in this paper for highly compact 3D freeform illumination systems. In the first step, a target shape scaling strategy is combined with an iterative feedback modification algorithm to generate an optimized freeform optical system with a well-controlled boundary of the target distribution. In the second step, a set of selected radii of the system obtained in the first step are optimized to further improve the illuminating quality within the target region. The method is quite flexible and effective to design highly compact optical systems with almost no restriction on the shape of the desired target field. As examples, three highly compact freeform lenses with ratio of center height h of the lens and the maximum dimension D of the source ≤ 2.5:1 are designed for LED surface light sources to form a uniform illumination distribution on a rectangular, a cross-shaped and a complex cross pierced target plane respectively. High light control efficiency of η > 0.7 as well as low relative standard illumination deviation of RSD < 0.07 is obtained simultaneously for all the three design examples.

  13. Parallel phase-sensitive three-dimensional imaging camera

    DOEpatents

    Smithpeter, Colin L.; Hoover, Eddie R.; Pain, Bedabrata; Hancock, Bruce R.; Nellums, Robert O.

    2007-09-25

    An apparatus is disclosed for generating a three-dimensional (3-D) image of a scene illuminated by a pulsed light source (e.g. a laser or light-emitting diode). The apparatus, referred to as a phase-sensitive 3-D imaging camera utilizes a two-dimensional (2-D) array of photodetectors to receive light that is reflected or scattered from the scene and processes an electrical output signal from each photodetector in the 2-D array in parallel using multiple modulators, each having inputs of the photodetector output signal and a reference signal, with the reference signal provided to each modulator having a different phase delay. The output from each modulator is provided to a computational unit which can be used to generate intensity and range information for use in generating a 3-D image of the scene. The 3-D camera is capable of generating a 3-D image using a single pulse of light, or alternately can be used to generate subsequent 3-D images with each additional pulse of light.

  14. Direct design of aspherical lenses for extended non-Lambertian sources in three-dimensional rotational geometry

    PubMed Central

    Wu, Rengmao; Hua, Hong

    2016-01-01

    Illumination design used to redistribute the spatial energy distribution of light source is a key technique in lighting applications. However, there is still no effective illumination design method for extended sources, especially for extended non-Lambertian sources. What we present here is to our knowledge the first direct method for extended non-Lambertian sources in three-dimensional (3D) rotational geometry. In this method, both meridional rays and skew rays of the extended source are taken into account to tailor the lens profile in the meridional plane. A set of edge rays and interior rays emitted from the extended source which will take a given direction after the refraction of the aspherical lens are found by the Snell’s law, and the output intensity at this direction is then calculated to be the integral of the luminance function of the outgoing rays at this direction. This direct method is effective for both extended non-Lambertian sources and extended Lambertian sources in 3D rotational symmetry, and can directly find a solution to the prescribed design problem without cumbersome iterative illuminance compensation. Two examples are presented to demonstrate the effectiveness of the proposed method in terms of performance and capacity for tackling complex designs. PMID:26832484

  15. Self-referencing spectrophotometric measurements

    DOEpatents

    O'Rourke, P.E.; Van Hare, D.R.

    1994-03-29

    A method is described for measuring the concentration of a chemical substance by spectrophotometry comprising the steps of placing a sample of a photoreactive substance between the light source and a spectrophotometer, obtaining an absorption spectrum of the substance using a fixed amount of light from the light source, obtaining a second absorption spectrum after a short interval, comparing the two to determine the concentration of the chemical substance from the difference in the spectra. If the chemical substance is not photoreactive, a photoreactive mixture can be made with a photoreactive dye that has photoreactive properties unique to the mixture. Alternatively, an optically transparent substrate can absorb the substance or the dye/substance mixture. 3 figures.

  16. Behavioural responses of krill and cod to artificial light in laboratory experiments

    PubMed Central

    Løkkeborg, S.; Humborstad, O-B.

    2018-01-01

    Most fishes and crustaceans respond to light, and artificial light sources may therefore be an efficient stimulus to manipulate behaviours in aquatic animals. It has been hypothesised that the catch efficiency of pots could be increased if prey, for example krill, can be attracted into the pots providing a visual stimulus and a source of live bait. To find which light characteristics are most attractive to krill, we tested the effects of light intensity and wavelength composition on Northern krill’s (Meganyctiphanes norvegica) behavioural response to an artificial light source. The most attractive individual wavelength was 530 nm (green light), while broadband (425–750 nm) white light was an equally attractive light source. The intensity of the emitted light did not appear to have a direct effect on attraction to the light source, however it did significantly increase swimming activity among the observed krill. The most promising light stimuli for krill were tested to determine whether they would have a repulsive or attractive effect on cod (Gadus morhua); These light stimuli appeared to have a slightly repulsive, but non-significant, effect on cod. However, we suggest that a swarm of krill attracted to an artificial light source may produce a more effective visual stimulus to foraging cod. PMID:29370231

  17. Behavioural responses of krill and cod to artificial light in laboratory experiments.

    PubMed

    Utne-Palm, A C; Breen, M; Løkkeborg, S; Humborstad, O-B

    2018-01-01

    Most fishes and crustaceans respond to light, and artificial light sources may therefore be an efficient stimulus to manipulate behaviours in aquatic animals. It has been hypothesised that the catch efficiency of pots could be increased if prey, for example krill, can be attracted into the pots providing a visual stimulus and a source of live bait. To find which light characteristics are most attractive to krill, we tested the effects of light intensity and wavelength composition on Northern krill's (Meganyctiphanes norvegica) behavioural response to an artificial light source. The most attractive individual wavelength was 530 nm (green light), while broadband (425-750 nm) white light was an equally attractive light source. The intensity of the emitted light did not appear to have a direct effect on attraction to the light source, however it did significantly increase swimming activity among the observed krill. The most promising light stimuli for krill were tested to determine whether they would have a repulsive or attractive effect on cod (Gadus morhua); These light stimuli appeared to have a slightly repulsive, but non-significant, effect on cod. However, we suggest that a swarm of krill attracted to an artificial light source may produce a more effective visual stimulus to foraging cod.

  18. 3D Monte Carlo model with direct photon flux recording for optimal optogenetic light delivery

    NASA Astrophysics Data System (ADS)

    Shin, Younghoon; Kim, Dongmok; Lee, Jihoon; Kwon, Hyuk-Sang

    2017-02-01

    Configuring the light power emitted from the optical fiber is an essential first step in planning in-vivo optogenetic experiments. However, diffusion theory, which was adopted for optogenetic research, precluded accurate estimates of light intensity in the semi-diffusive region where the primary locus of the stimulation is located. We present a 3D Monte Carlo model that provides an accurate and direct solution for light distribution in this region. Our method directly records the photon trajectory in the separate volumetric grid planes for the near-source recording efficiency gain, and it incorporates a 3D brain mesh to support both homogeneous and heterogeneous brain tissue. We investigated the light emitted from optical fibers in brain tissue in 3D, and we applied the results to design optimal light delivery parameters for precise optogenetic manipulation by considering the fiber output power, wavelength, fiber-to-target distance, and the area of neural tissue activation.

  19. Detection of Transionospheric SuperDARN HF Waves by the Radio Receiver Instrument on the enhanced Polar Outflow Probe Satellite

    NASA Astrophysics Data System (ADS)

    Gillies, R. G.; Yau, A. W.; James, H. G.; Hussey, G. C.; McWilliams, K. A.

    2014-12-01

    The enhanced Polar Outflow Probe (ePOP) Canadian small-satellite was launched in September 2013. Included in this suite of eight scientific instruments is the Radio Receiver Instrument (RRI). The RRI has been used to measure VLF and HF radio waves from various ground and spontaneous ionospheric sources. The first dedicated ground transmission that was detected by RRI was from the Saskatoon Super Dual Auroral Radar Network (SuperDARN) radar on Nov. 7, 2013 at 14 MHz. Several other passes over the Saskatoon SuperDARN radar have been recorded since then. Ground transmissions have also been observed from other radars, such as the SPEAR, HAARP, and SURA ionospheric heaters. However, the focus of this study will be on the results obtained from the SuperDARN passes. An analysis of the signal recorded by the RRI provides estimates of signal power, Doppler shift, polarization, absolute time delay, differential mode delay, and angle of arrival. By comparing these parameters to similar parameters derived from ray tracing simulations, ionospheric electron density structures may be detected and measured. Further analysis of the results from the other ground transmitters and future SuperDARN passes will be used to refine these results.

  20. Alouette and ISIS topside sounder measurements -A data source for improvements of the IRI model in the topside ionosphere

    NASA Astrophysics Data System (ADS)

    Bilitza, Dieter; Benson, Robert; Reinisch, Bodo; Huang, Xueqin

    The Alouette and ISIS topside sounder satellites recorded a great wealth of information about the topside ionosphere during their long period of operations (from 1962 to 1990). So much though that only a small percentage was analyzed during the mission life time. The soundings were stored on more than 100,000 seven-track analog telemetry tapes. In the mid-nineties space limitations and storage costs threatened an imminent loss of these tapes. Only a last minute intervention spear-headed by NASA's Ionosphere, Thermosphere, Mesosphere (ITM) Data Evaluation Panel saved a significant portion of these tapes and with funding from the AISRP program these data were first digitized and then converted into electron density profiles. This data restoration effort more than tripled the Alouette/ISIS topside sounder data base and has led to significant improvements of models for the topside ionosphere, e.g., about a factor of 2 improvement in the case of the IRI-2007 topside electron density profile. We will present a brief history of this successful data restoration effort and its current status. The homepage for the ISIS project is at http://nssdc.gsfc.nasa.gov/space/isis/isis-status.html.

  1. Preclinical imaging of iridocorneal angle and fundus using a modified integrated flexible handheld probe

    PubMed Central

    Hong, Xun Jie Jeesmond; Shinoj, Vengalathunadakal K.; Murukeshan, Vadakke Matham; Baskaran, Mani; Aung, Tin

    2017-01-01

    Abstract. A flexible handheld imaging probe consisting of a 3  mm×3  mm charge-coupled device camera, light-emitting diode light sources, and near-infrared laser source is designed and developed. The imaging probe is designed with specifications to capture the iridocorneal angle images and posterior segment images. Light propagation from the anterior chamber of the eye to the exterior is considered analytically using Snell’s law. Imaging of the iridocorneal angle region and fundus is performed on ex vivo porcine samples and subsequently on small laboratory animals, such as the New Zealand white rabbit and nonhuman primate, in vivo. The integrated flexible handheld probe demonstrates high repeatability in iridocorneal angle and fundus documentation. The proposed concept and methodology are expected to find potential application in the diagnosis, prognosis, and management of glaucoma. PMID:28413809

  2. High efficiency light source using solid-state emitter and down-conversion material

    DOEpatents

    Narendran, Nadarajah; Gu, Yimin; Freyssinier, Jean Paul

    2010-10-26

    A light emitting apparatus includes a source of light for emitting light; a down conversion material receiving the emitted light, and converting the emitted light into transmitted light and backward transmitted light; and an optic device configured to receive the backward transmitted light and transfer the backward transmitted light outside of the optic device. The source of light is a semiconductor light emitting diode, a laser diode (LD), or a resonant cavity light emitting diode (RCLED). The down conversion material includes one of phosphor or other material for absorbing light in one spectral region and emitting light in another spectral region. The optic device, or lens, includes light transmissive material.

  3. Product selectivity of visible-light photocatalytic reduction of carbon dioxide using titanium dioxide doped by different nitrogen-sources

    NASA Astrophysics Data System (ADS)

    Zhang, Zhaoguo; Huang, Zhengfeng; Cheng, Xudong; Wang, Qingli; Chen, Yi; Dong, Peimei; Zhang, Xiwen

    2015-11-01

    The influence of nitrogen-source on the photocatalytic properties of nitrogen-doped titanium dioxide is herein first investigated from the perspective of the chemical bond form of the nitrogen element in the nitrogen-source. The definitive role of groups such as Nsbnd N from the nitrogen-source on the surface of as-prepared samples in the selectivity of the dominant product of photocatalytic reduction is demonstrated. Well-crystallized one-dimensional Nsbnd TiO2 nanorod arrays with a preferred orientation of the rutile (3 1 0) facet are manufactured via a hydrothermal treatment using hydrazine and ammonia variously as the source of nitrogen. Significant selectivity of the dominant reduced products has been exhibited for Nsbnd TiO2 prepared from different nitrogen-sources in carbon dioxide photocatalytic reduction under visible light illumination. CH4 is the main product with N2H4-doped Nsbnd TiO2, while CO is the main product with NH3-doped Nsbnd TiO2, which can be attributed to the existence of the reducing Nsbnd N groups in the N2H4-doped Nsbnd TiO2 surfaces after the hydrothermal treatment. Compared with the approaches previously reported, the facile one-step route utilized here accomplishes the fabrication of Nsbnd TiO2 possessing visible-light activity and attainment of selectivity of dominant photocatalytic reduction product simultaneously by choosing a nitrogen-source with appropriate chemical bond form, which provides a completely new approach to understanding the effects of doping treatment on photocatalytic properties.

  4. Silicon micromachined broad band light source

    NASA Technical Reports Server (NTRS)

    George, Thomas (Inventor); Jones, Eric (Inventor); Tuma, Margaret L. (Inventor); Eastwood, Michael (Inventor); Hansler, Richard (Inventor)

    2004-01-01

    A micro electromechanical system (MEMS) broad band incandescent light source includes three layers: a top transmission window layer; a middle filament mount layer; and a bottom reflector layer. A tungsten filament with a spiral geometry is positioned over a hole in the middle layer. A portion of the broad band light from the heated filament is reflective off the bottom layer. Light from the filament and the reflected light of the filament are transmitted through the transmission window. The light source may operate at temperatures of 2500 K or above. The light source may be incorporated into an on board calibrator (OBC) for a spectrometer.

  5. A two-metric proposal to specify the color-rendering properties of light sources for retail lighting

    NASA Astrophysics Data System (ADS)

    Freyssinier, Jean Paul; Rea, Mark

    2010-08-01

    Lighting plays an important role in supporting retail operations, from attracting customers, to enabling the evaluation of merchandise, to facilitating the completion of the sale. Lighting also contributes to the identity, comfort, and visual quality of a retail store. With the increasing availability and quality of white LEDs, retail lighting specifiers are now considering LED lighting in stores. The color rendering of light sources is a key factor in supporting retail lighting goals and thus influences a light source's acceptance by users and specifiers. However, there is limited information on what consumers' color preferences are, and metrics used to describe the color properties of light sources often are equivocal and fail to predict preference. The color rendering of light sources is described in the industry solely by the color rendering index (CRI), which is only indirectly related to human perception. CRI is intended to characterize the appearance of objects illuminated by the source and is increasingly being challenged because new sources are being developed with increasingly exotic spectral power distributions. This paper discusses how CRI might be augmented to better use it in support of the design objectives for retail merchandising. The proposed guidelines include the use of gamut area index as a complementary metric to CRI for assuring good color rendering.

  6. Effect of laser speckle on light from laser diode-pumped phosphor-converted light sources.

    PubMed

    Aquino, Felipe; Jadwisienczak, Wojciech M; Rahman, Faiz

    2017-01-10

    Laser diode (LD) pumped white light sources are being developed as an alternative to light-emitting diode-pumped sources for high efficiency and/or high brightness applications. While several performance metrics of laser-pumped phosphor-converted light sources have been investigated, the effect of laser speckle has not been sufficiently explored. This paper describes our experimental studies on how laser speckle affects the behavior of light from laser-excited phosphor lamps. A single LD pumping a phosphor plate was the geometry explored in this work. Overall, our findings are that the down-converted light did not exhibit any speckle, whereas speckle was present in the residual pump light but much reduced from that in direct laser light. Furthermore, a thicker coating of small-grained phosphors served to effectively reduce speckle through static pump light diffusion in the phosphor coating. Our investigations showed that speckle is not of concern in illumination from LD-pumped phosphor-converted light sources.

  7. Cylindrical angular spectrum using Fourier coefficients of point light source and its application to fast hologram calculation.

    PubMed

    Oh, Seungtaik; Jeong, Il Kwon

    2015-11-16

    We will introduce a new simple analytic formula of the Fourier coefficient of the 3D field distribution of a point light source to generate a cylindrical angular spectrum which captures the object wave in 360° in the 3D Fourier space. Conceptually, the cylindrical angular spectrum can be understood as a cylindrical version of the omnidirectional spectral approach of Sando et al. Our Fourier coefficient formula is based on an intuitive observation that a point light radiates uniformly in all directions. Our formula is defined over all frequency vectors lying on the entire sphere in the 3D Fourier space and is more natural and computationally more efficient for all around recording of the object wave than that of the previous omnidirectional spectral method. A generalized frequency-based occlusion culling method for an arbitrary complex object is also proposed to enhance the 3D quality of a hologram. As a practical application of the cylindrical angular spectrum, an interactive hologram example is presented together with implementation details.

  8. Evaluating white LEDs for outdoor landscape lighting application

    NASA Astrophysics Data System (ADS)

    Shakir, Insiya; Narendran, Nadarajah

    2002-11-01

    A laboratory experiment was conducted to understand the acceptability of different white light emitting diodes (LEDs) for outdoor landscape lighting. The study used a scaled model setup. The scene was designed to replicate the exterior of a typical upscale suburban restaurant including the exterior facade of the building, an approach with steps, and a garden. The lighting was designed to replicate light levels commonly found in nighttime outdoor conditions. The model had a central dividing partition with symmetrical scenes on both sides for side-by-side evaluations of the two scenes with different light sources. While maintaining equal luminance levels and distribution between the two scenes, four types of light sources were evaluated. These include, halogen, phosphor white LED, and two white light systems using RGB LEDs. These light sources were tested by comparing two sources at a time placed side-by-side and by individual assessment of each lighting condition. The results showed that the RGB LEDs performed equal or better than the most widely used halogen light source in this given setting. A majority of the subjects found slightly dimmer ambient lighting to be more typical for restaurants and therefore found RGB LED and halogen light sources to be more inviting. The phosphor white LEDs made the space look brighter, however a majority of the subjects disliked them.

  9. Can Biomass Burning Explain Isotopically Light Fe in Marine Aerosols?

    NASA Astrophysics Data System (ADS)

    Sherry, A. M.; Anbar, A. D.; Herckes, P.; Romaniello, S. J.

    2016-02-01

    Iron (Fe) is an important micronutrient that limits primary productivity in large parts of the ocean. In these regions, atmospheric aerosol deposition is an important source of Fe to the surface ocean and thus has a critical impact on ocean biogeochemistry. Fe-bearing aerosols originate from many sources with potentially distinct Fe isotopic compositions. Consequently, Fe isotopes may provide a new tool to trace the sources of aerosol Fe to the oceans. Mead et al. (2013) first discovered that Fe in the fine fraction of Bermuda aerosols is often isotopically lighter than Fe from known anthropogenic and crustal sources. 1 These authors suggested that this light isotopic signature was likely the result of biomass burning, since Fe in plants is the only known source of isotopically light Fe. More recently, Conway et al. found that Fe in the soluble fraction of aerosols collected during 2010-2011 North Atlantic GEOTRACES cruises also showed light isotope values, which they likewise attributed to biomass burning.2 These studies are further supported by new modeling work which suggests that biomass burning aerosols should contribute significant amounts of soluble Fe to tropical and southern oceans.3To test if biomass burning releases aerosols with a light Fe isotope composition, we are conducting lab-scale biomass burning experiments using natural samples of vegetation and leaf litter. Burn aerosols were collected on cellulose filters, then digested and analyzed for trace metal concentrations using inductively-coupled mass spectrometry (ICP-MS). Fe isotopes were determined by using multiple collector ICP-MS following separation and purification of Fe using anion exchange chromatography. We will discuss metal concentration and isotope data from these experiments with implications for the interpretation of Fe isotope signals in aerosol samples. 1Mead, C et al. GRL, 2013, 40, 5722-5727. 2 Conway, T et al. Goldschmidt Abs 2015 593. 3Ito, A. ES&T Lett, 2015, 2, 70-75.

  10. Study on Formulation of Optimum Lighting-system for Purchasing Power at Stores

    NASA Astrophysics Data System (ADS)

    Fujita, Hiroki; Nakashima, Yoshio; Takamatsu, Mamoru; Oota, Masaaki; Sawa, Kazuhiro

    In store lighting, difference in the look-and-feel of foods gives effects on the purchasing power of customers. This study conducted the digitalization and quantification on the effects of the variation of light-source color and illuminance used for lighting foods on image recognition on foods. As a result, it was clarified that when meat was illuminated with the light source of “pink” or “faint pink,” image evaluation on foods became higher. In addition, when illuminance increase was applied to these two light-source colors, image evaluation on “faint pink” became further higher. The reason is supposed to be that the redness of meat increased, which may have enhanced fresher impression. From this study, it has been clarified that the light-source color and illuminance optimum for each food are variant. The results show that lighting foods with the optimum light-source color and illuminance can make foods look better.

  11. Scaled SFS method for Lambertian surface 3D measurement under point source lighting.

    PubMed

    Ma, Long; Lyu, Yi; Pei, Xin; Hu, Yan Min; Sun, Feng Ming

    2018-05-28

    A Lambertian surface is a kind of very important assumption in shape from shading (SFS), which is widely used in many measurement cases. In this paper, a novel scaled SFS method is developed to measure the shape of a Lambertian surface with dimensions. In which, a more accurate light source model is investigated under the illumination of a simple point light source, the relationship between surface depth map and the recorded image grayscale is established by introducing the camera matrix into the model. Together with the constraints of brightness, smoothness and integrability, the surface shape with dimensions can be obtained by analyzing only one image using the scaled SFS method. The algorithm simulations show a perfect matching between the simulated structures and the results, the rebuilding root mean square error (RMSE) is below 0.6mm. Further experiment is performed by measuring a PVC tube internal surface, the overall measurement error lies below 2%.

  12. X-ray metrology of an array of active edge pixel sensors for use at synchrotron light sources

    NASA Astrophysics Data System (ADS)

    Plackett, R.; Arndt, K.; Bortoletto, D.; Horswell, I.; Lockwood, G.; Shipsey, I.; Tartoni, N.; Williams, S.

    2018-01-01

    We report on the production and testing of an array of active edge silicon sensors as a prototype of a large array. Four Medipix3RX.1 chips were bump bonded to four single chip sized Advacam active edge n-on-n sensors. These detectors were then mounted into a 2 by 2 array and tested on B16 at Diamond Light Source with an x-ray beam spot of 2um. The results from these tests, compared with optical metrology demonstrate that this type of sensor is sensitive to the physical edge of the silicon, with only a modest loss of efficiency in the final two rows of pixels. We present the efficiency maps recorded with the microfocus beam and a sample powder diffraction measurement. These results give confidence that this sensor technology can be used effectively in larger arrays of detectors at synchrotron light sources.

  13. Light source comprising a common substrate, a first led device and a second led device

    DOEpatents

    Choong, Vi-En

    2010-02-23

    At least one stacked organic or polymeric light emitting diode (PLEDs) devices to comprise a light source is disclosed. At least one of the PLEDs includes a patterned cathode which has regions which transmit light. The patterned cathodes enable light emission from the PLEDs to combine together. The light source may be top or bottom emitting or both.

  14. Laser-induced micro-plasmas in air for incoherent broadband cavity-enhanced absorption spectroscopy

    NASA Astrophysics Data System (ADS)

    Ruth, Albert; Dixneuf, Sophie; Orphal, Johannes

    2016-04-01

    Incoherent broadband cavity-enhanced absorption spectroscopy (IBBCEAS) is an experimentally straightforward absorption method where the intensity of light transmitted by an optically stable (high finesse) cavity is measured. The technique is realized using broadband incoherent sources of radiation and therefore the amount of light transmitted by a cavity consisting of high reflectance mirrors (typically R > 99.9%) can be low. In order to find an alternative to having an incoherent light source outside the cavity, an experiment was devised, where a laser-induced plasma in ambient air was generated inside a quasi-confocal cavity by a high-power femtosecond laser. The emission from the laser-induced plasma was utilized as pulsed broadband light source. The time-dependent spectra of the light leaking from the cavity were compared with those of the laser-induced plasma emission without the cavity. It was found that the light emission was sustained by the cavity despite the initially large optical losses caused by the laser-induced plasma in the cavity. The light sustained by the cavity was used to measure part of the S1 ← S0 absorption spectrum of gaseous azulene at its vapour pressure at room temperature in ambient air, as well as the strongly forbidden γ-band in molecular oxygen (b1Σ(2,0) ← X3Σ(0,0)).

  15. Visible-Light-Promoted Trifluoromethylthiolation of Styrenes by Dual Photoredox/Halide Catalysis.

    PubMed

    Honeker, Roman; Garza-Sanchez, R Aleyda; Hopkinson, Matthew N; Glorius, Frank

    2016-03-18

    Herein, we report a new visible-light-promoted strategy to access radical trifluoromethylthiolation reactions by combining halide and photoredox catalysis. This approach allows for the synthesis of vinyl-SCF3 compounds of relevance in pharmaceutical chemistry directly from alkenes under mild conditions with irradiation from household light sources. Furthermore, alkyl-SCF3-containing cyclic ketone and oxindole derivatives can be accessed by radical-polar crossover semi-pinacol and cyclization processes. Inexpensive halide salts play a crucial role in activating the trifluoromethylthiolating reagent towards photoredox catalysis and aid the formation of the SCF3 radical. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Low-picomolar limits of detection using high-power light-emitting diodes for fluorescence.

    PubMed

    de Jong, Ebbing P; Lucy, Charles A

    2006-05-01

    Fluorescence detectors are ever more frequently being used with light-emitting diodes (LEDs) as the light source. Technological advances in the solid-state lighting industry have produced LEDs which are also suitable tools in analytical measurements. LEDs are now available which deliver 700 mW of radiometric power. While this greater light power can increase the fluorescence signal, it is not trivial to make proper use of this light. This new generation of LEDs has a large emitting area and a highly divergent beam. This presents a classic problem in optics where one must choose between either a small focused light spot, or high light collection efficiency. We have selected for light collection efficiency, which yields a light spot somewhat larger than the emitting area of the LED. This light is focused onto a flow cell. Increasing the detector cell internal diameter (i.d.) produces gains in (sensitivity)3. However, since the detector cell i.d. is smaller than the LED spot size, scattering of excitation light towards the detector remains a significant source of background signal. This can be minimized through the use of spectral filters and spatial filters in the form of pinholes. The detector produced a limit of detection (LOD) of 3 pM, which is roughly three orders of magnitude lower than other reports of LED-based fluorescence detectors. Furthermore, this LOD comes within a factor of six of much more expensive laser-based fluorescence systems. This detector has been used to monitor a separation from a gel filtration column of fluorescently labeled BSA from residual labeling reagent. The LOD of fluorescently labeled BSA is 25 pM.

  17. Exploring Direct 3D Interaction for Full Horizontal Parallax Light Field Displays Using Leap Motion Controller

    PubMed Central

    Adhikarla, Vamsi Kiran; Sodnik, Jaka; Szolgay, Peter; Jakus, Grega

    2015-01-01

    This paper reports on the design and evaluation of direct 3D gesture interaction with a full horizontal parallax light field display. A light field display defines a visual scene using directional light beams emitted from multiple light sources as if they are emitted from scene points. Each scene point is rendered individually resulting in more realistic and accurate 3D visualization compared to other 3D displaying technologies. We propose an interaction setup combining the visualization of objects within the Field Of View (FOV) of a light field display and their selection through freehand gesture tracked by the Leap Motion Controller. The accuracy and usefulness of the proposed interaction setup was also evaluated in a user study with test subjects. The results of the study revealed high user preference for free hand interaction with light field display as well as relatively low cognitive demand of this technique. Further, our results also revealed some limitations and adjustments of the proposed setup to be addressed in future work. PMID:25875189

  18. DUV light source availability improvement via further enhancement of gas management technologies

    NASA Astrophysics Data System (ADS)

    Riggs, Daniel J.; O'Brien, Kevin; Brown, Daniel J. W.

    2011-04-01

    The continuous evolution of the semiconductor market necessitates ever-increasing improvements in DUV light source uptime as defined in the SEMI E10 standard. Cymer is developing technologies to exceed current and projected light source availability requirements via significant reduction in light source downtime. As an example, consider discharge chamber gas management functions which comprise a sizable portion of DUV light source downtime. Cymer's recent introduction of Gas Lifetime Extension (GLXTM) as a productivity improvement technology for its DUV lithography light sources has demonstrated noteworthy reduction in downtime. This has been achieved by reducing the frequency of full gas replenishment events from once per 100 million pulses to as low as once per 2 billion pulses. Cymer has continued to develop relevant technologies that target further reduction in downtime associated with light source gas management functions. Cymer's current subject is the development of technologies to reduce downtime associated with gas state optimization (e.g. total chamber gas pressure) and gas life duration. Current gas state optimization involves execution of a manual procedure at regular intervals throughout the lifetime of light source core components. Cymer aims to introduce a product enhancement - iGLXTM - that eliminates the need for the manual procedure and, further, achieves 4 billion pulse gas lives. Projections of uptime on DUV light sources indicate that downtime associated with gas management will be reduced by 70% when compared with GLX2. In addition to reducing downtime, iGLX reduces DUV light source cost of operation by constraining gas usage. Usage of fluorine rich Halogen gas mix has been reduced by 20% over GLX2.

  19. Design and evaluation of excitation light source device for fluorescence endoscope

    NASA Astrophysics Data System (ADS)

    Lim, Hyun Soo

    2009-06-01

    This study aims at designing and evaluating light source devices that can stably generate light with various wavelengths in order to make possible PDD using a photosensitizer and diagnosis using auto-fluorescence. The light source was a Xenon lamp and filter wheel, composed of an optical output control through Iris and filters with several wavelength bands. It also makes the inducement of auto-fluorescence possible because it is designed to generate a wavelength band of 380-420nm, 430-480nm, and 480-560nm. The transmission part of the light source was developed to enhance the efficiency of light transmission. To evaluate this light source, the characteristics of light output and wavelength band were verified. To validate the capability of this device as PDD, the detection of auto-fluorescence using mouse models was performed.

  20. Modeling of an Adjustable Beam Solid State Light Project

    NASA Technical Reports Server (NTRS)

    Clark, Toni

    2015-01-01

    This proposal is for the development of a computational model of a prototype variable beam light source using optical modeling software, Zemax Optics Studio. The variable beam light source would be designed to generate flood, spot, and directional beam patterns, while maintaining the same average power usage. The optical model would demonstrate the possibility of such a light source and its ability to address several issues: commonality of design, human task variability, and light source design process improvements. An adaptive lighting solution that utilizes the same electronics footprint and power constraints while addressing variability of lighting needed for the range of exploration tasks can save costs and allow for the development of common avionics for lighting controls.

  1. Design and Fabrication of Multifunctional Portable Bi2Te3-Based Thermoelectric Camping Lamp

    NASA Astrophysics Data System (ADS)

    Zhou, Yi; Li, Gongping

    2018-05-01

    Camping lamps have been widely used in the lighting, power supply, and intelligent electronic equipment fields. However, applications of traditional chemical and solar camping lamps are largely limited by the physical size of the source and operating conditions. A new prototype multifunctional portable Bi2Te3-based thermoelectric camping lamp (TECL) has been designed and fabricated. Ten parallel light-emitting diodes were lit directly by a Bi2Te3-based thermoelectric generator (TEG). The highest short-circuit current of 0.38 A and open-circuit voltage of 4.2 V were obtained at temperature difference of 115 K. This TECL is attractive for use in multifunctional and extreme applications as it integrates a portable heat source, high-performance TEG, and power management unit.

  2. Design and Fabrication of Multifunctional Portable Bi2Te3-Based Thermoelectric Camping Lamp

    NASA Astrophysics Data System (ADS)

    Zhou, Yi; Li, Gongping

    2018-07-01

    Camping lamps have been widely used in the lighting, power supply, and intelligent electronic equipment fields. However, applications of traditional chemical and solar camping lamps are largely limited by the physical size of the source and operating conditions. A new prototype multifunctional portable Bi2Te3-based thermoelectric camping lamp (TECL) has been designed and fabricated. Ten parallel light-emitting diodes were lit directly by a Bi2Te3-based thermoelectric generator (TEG). The highest short-circuit current of 0.38 A and open-circuit voltage of 4.2 V were obtained at temperature difference of 115 K. This TECL is attractive for use in multifunctional and extreme applications as it integrates a portable heat source, high-performance TEG, and power management unit.

  3. An experiment on the color rendering of different light sources

    NASA Astrophysics Data System (ADS)

    Fumagalli, Simonetta; Bonanomi, Cristian; Rizzi, Alessandro

    2013-02-01

    The color rendering index (CRI) of a light source attempts to measure how much the color appearance of objects is preserved when they are illuminated by the given light source. This problem is of great importance for various industrial and scientific fields, such as lighting architecture, design, ergonomics, etc. Usually a light source is specified through the Correlated Color Temperature or CCT. However two (or more) light sources with the same CCT but different spectral power distribution can exist. Therefore color samples viewed under two light sources with equal CCTs can appear different. Hence, the need for a method to assess the quality of a given illuminant in relation to color. Recently CRI has had a renewed interest because of the new LED-based lighting systems. They usually have a color rendering index rather low, but good preservation of color appearance and a pleasant visual appearance (visual appeal). Various attempts to develop a new color rendering index have been done so far, but still research is working for a better one. This article describes an experiment performed by human observers concerning the appearance preservation of color under some light sources, comparing it with a range of available color rendering indices.

  4. A visible light-curable yet visible wavelength-transparent resin for stereolithography 3D printing

    NASA Astrophysics Data System (ADS)

    Park, Hong Key; Shin, Mikyung; Kim, Bongkyun; Park, Jin Woo; Lee, Haeshin

    2018-04-01

    Herein, a new polymeric resin for stereolithography (SLA) three-dimensional printing (SLA-3DP) is reported. An ultraviolet (UV) or visible (VIS) light source is critical for SLA printing technology. UV light can be used to manufacture 3D objects in SLA-3DP, but there are significant occupational safety and health issues (particularly for eyes). These issues prevent the widespread use of SLA-3DP at home or in the office. Through the use of VIS light, the safety and health issues can largely be solved, but only non-transparent 3D objects can be manufactured, which prevents the application of 3DP to the production of various common transparent consumer products. For these reasons, we developed a VIS light-curable yet visibly transparent resin for SLA-3DP, which also retains UV curability. The key was to identify the photoinitiator diphenyl(2,4,6-trimethylbenzoyl)phosphine oxide (DPTBP). DPTBP was originally designed as a UV photoinitiator, but we found that VIS light irradiation is sufficient to split DPTBP and generate radicals due to its slight VIS light absorption up to 420 nm. The cured resin displays high transparency and beautiful transparent colors by incorporating various dyes; additionally, its mechanical properties are superior to those of commercial resins (Arario 410) and photoinitiators (Irgacure 2959).

  5. Synchrotron Light Sources in Developing Countries

    NASA Astrophysics Data System (ADS)

    Winick, Herman; Pianetta, Piero

    The more than 50 light sources in operation include facilities in Brazil, Korea, and Taiwan which started in the 1980's when they were developing countries. They came on line in the 1990's and have since trained hundreds of graduate students. They have attracted mid-career diaspora scientists to return. Growing user communities have demanded more advanced facilities, leading to higher performance new light sources that are now coming into operation. Light sources in the developing world now include the following: ∖textbf{SESAME}in the Middle East which is scheduled to start research in 2017 (∖underline {www.sesame.org}); ∖textbf{The African Light Source}, in the planning stage (∖underline {www.safricanlightsource.org}); and ∖textbf{The Mexican Light Source}, in the planning stage (∖underline {http://www.aps.org/units/fip/newsletters/201509/mexico.cfm}). See: http://wpj.sagepub.com/content/32/4/92.full.pdf +html; http://www.lightsources.org/press-release/2015/11/20/grenoble-resolutions-mark-historical-step-towards-african-light-source..

  6. Reduction of background clutter in structured lighting systems

    DOEpatents

    Carlson, Jeffrey J.; Giles, Michael K.; Padilla, Denise D.; Davidson, Jr., Patrick A.; Novick, David K.; Wilson, Christopher W.

    2010-06-22

    Methods for segmenting the reflected light of an illumination source having a characteristic wavelength from background illumination (i.e. clutter) in structured lighting systems can comprise pulsing the light source used to illuminate a scene, pulsing the light source synchronously with the opening of a shutter in an imaging device, estimating the contribution of background clutter by interpolation of images of the scene collected at multiple spectral bands not including the characteristic wavelength and subtracting the estimated background contribution from an image of the scene comprising the wavelength of the light source and, placing a polarizing filter between the imaging device and the scene, where the illumination source can be polarized in the same orientation as the polarizing filter. Apparatus for segmenting the light of an illumination source from background illumination can comprise an illuminator, an image receiver for receiving images of multiple spectral bands, a processor for calculations and interpolations, and a polarizing filter.

  7. Effect of leafhopper Arboridiakurdistanisp.nov on the some grape leaves elements and its chemical control

    NASA Astrophysics Data System (ADS)

    Amin, Abdulbaset Mohammed; Younis, Sara Dasco

    2017-09-01

    The leafhopper Arboridiakurdistanisucking leaves sap and causes decrease of nitrogen in leaves and lead to inhabiting the chlorophyll then decrease the rate of photosynthesis and drying of the leaf. Chemical analysis of plant leaves showed the decreasing of Nitrogen content and gave the means in July, August and September 2.699%, 2.531% and 2.063% respectively, The phosphors rate is decrease in infested leaves, the mean of phosphors content in infested leaves in July, August and September were 0.532ppm, 0.496ppm and 0.361ppm respectively. At the time of protein is decreased in grape leaves the plants should delay in growth, the proteins content were 16.865%, 15.814% and 14.689%, while the potassium content in infested grape leave in July, August and September were 0.509%, 0.509% and 0.394% respectively. The chemical control showed that the best insecticide was Actara which gave 23.33% mortality for 48hours at 0.5gm/gallon water and raised to 90.00% at rate of 1.5gm/gallon water, Marshal gave 13.33% and 80.00% after 48 hours at rate of 0.5 and 1.5gm/gallon water respectively, but Spear gave 6.67% and 33.33% after 48 hours at 0.5% and 1.5gm/gallon water respectively. Based on LC50 Value, Actara proved to be more effective than Marshal and Spear.

  8. The unicorn and the narwhal: a tale of the tooth.

    PubMed

    Christen, Arden G; Christen, Joan A

    2011-01-01

    From as far back as the early Roman era, detailed descriptions and artistic images of the unicorn have been imagined. In Europe, the Mediterranean and the Far East, this creature became accepted as real. Although such an animal had never actually been seen, it was said to have the appearance of a horse, the beard and cloven hooves of a goat, the tail of a lion, and a single, spear-like horn protruding from the center of its forehead. The unicorn myth originated shortly after unidentified horn-like objects, from six to ten feet long, began to appear in ancient European marketplaces. Physicians quickly ascribed outlandish healing properties to these horns, pulverizing them for the treatment of various diseases. In 1638, a Danish zoologist challenged these claims and provided evidence that the so-called "unicorn horn" was actually the tusk (tooth) of the narwhal from the Arctic seas. However, his findings remained unheeded for the next 100 years. This paper explains how the myth of the unicorn and the purported powers contained within the substance of its magical horn evolved from the ages-old spoils of the Arctic fishing trade, where the narwhal was primarily speared for food and secondarily, for the export value of its ivory tusk. This unusually long, pointed and protruding single tooth, which breaks through the upper lip and the left jaw of each male narwhal, became a highly valuable commodity over the following centuries, due to its believed supernatural origins and curative qualities.

  9. Advances in free-energy-based simulations of protein folding and ligand binding.

    PubMed

    Perez, Alberto; Morrone, Joseph A; Simmerling, Carlos; Dill, Ken A

    2016-02-01

    Free-energy-based simulations are increasingly providing the narratives about the structures, dynamics and biological mechanisms that constitute the fabric of protein science. Here, we review two recent successes. It is becoming practical: first, to fold small proteins with free-energy methods without knowing substructures and second, to compute ligand-protein binding affinities, not just their binding poses. Over the past 40 years, the timescales that can be simulated by atomistic MD are doubling every 1.3 years--which is faster than Moore's law. Thus, these advances are not simply due to the availability of faster computers. Force fields, solvation models and simulation methodology have kept pace with computing advancements, and are now quite good. At the tip of the spear recently are GPU-based computing, improved fast-solvation methods, continued advances in force fields, and conformational sampling methods that harness external information. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Light Source Matters--Students' Explanations about the Behavior of Light When Different Light Sources Are Used in Task Assignments of Optics

    ERIC Educational Resources Information Center

    Kesonen, Mikko Henri Petteri; Asikainen, Mervi Anita; Hirvonen, Pekka Emil

    2017-01-01

    In the present article, the context-dependency of student reasoning is studied in a context of optics. We investigated introductory students' explanations about the behavior of light when different light sources, namely a small light bulb and a laser, were used in otherwise identical task assignments. The data was gathered with the aid of pretest…

  11. Microelectromechanical Systems (MEMS) Broadband Light Source Developed

    NASA Technical Reports Server (NTRS)

    Tuma, Margaret L.

    2003-01-01

    A miniature, low-power broadband light source has been developed for aerospace applications, including calibrating spectrometers and powering miniature optical sensors. The initial motivation for this research was based on flight tests of a Fabry-Perot fiberoptic temperature sensor system used to detect aircraft engine exhaust gas temperature. Although the feasibility of the sensor system was proven, the commercial light source optically powering the device was identified as a critical component requiring improvement. Problems with the light source included a long stabilization time (approximately 1 hr), a large amount of heat generation, and a large input electrical power (6.5 W). Thus, we developed a new light source to enable the use of broadband optical sensors in aerospace applications. Semiconductor chip-based light sources, such as lasers and light-emitting diodes, have a relatively narrow range of emission wavelengths in comparison to incandescent sources. Incandescent light sources emit broadband radiation from visible to infrared wavelengths; the intensity at each wavelength is determined by the filament temperature and the materials chosen for the filament and the lamp window. However, present commercial incandescent light sources are large in size and inefficient, requiring several watts of electrical power to obtain the desired optical power, and they emit a large percentage of the input power as heat that must be dissipated. The miniature light source, developed jointly by the NASA Glenn Research Center, the Jet Propulsion Laboratory, and the Lighting Innovations Institute, requires one-fifth the electrical input power of some commercial light sources, while providing similar output light power that is easily coupled to an optical fiber. Furthermore, it is small, rugged, and lightweight. Microfabrication technology was used to reduce the size, weight, power consumption, and potential cost-parameters critical to future aerospace applications. This chip-based light source has the potential for monolithic fabrication with on-chip drive electronics. Other uses for these light sources are in systems for vehicle navigation, remote sensing applications such as monitoring bridges for stress, calibration sources for spectrometers, light sources for space sensors, display lighting, addressable arrays, and industrial plant monitoring. Two methods for filament fabrication are being developed: wet-chemical etching and laser ablation. Both yield a 25-mm-thick tungsten spiral filament. The proof-of-concept filament shown was fabricated with the wet etch method. Then it was tested by heating it in a vacuum chamber using about 1.25 W of electrical power; it generated bright, blackbody radiation at approximately 2650 K. The filament was packaged in Glenn's clean-room facilities. This design uses three chips vacuum-sealed with glass tape. The bottom chip consists of a reflective film deposited on silicon, the middle chip contains a tungsten filament bonded to silicon, and the top layer is a transparent window. Lifetime testing on the package will begin shortly. The emitted optical power is expected to be approximately 1.0 W with the spectral peak at 1.1 mm.

  12. Omega Dante soft x-ray power diagnostic component calibration at the National Synchrotron Light Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, K.M.; Weber, F.A.; Dewald, E.L.

    2004-10-01

    The Dante soft x-ray spectrometer, installed on the Omega laser facility at the Laboratory for Laser Energetics, University of Rochester, is a 12-channel filter-edge defined soft x-ray power diagnostic. It is used to measure the spectrally resolved, absolute flux from direct drive, indirect drive (hohlraums) and other plasma sources. Dante component calibration efforts using two beam lines, U3C (50 eV-1 keV) and X8A (1-6 keV) at the National Synchrotron Light Source have been implemented to improve the accuracy of these measurements. We have calibrated metallic vacuum x-ray diodes, mirrors and filters.

  13. 14 CFR 25.812 - Emergency lighting.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... sign required by § 25.811(d)(3) must have red letters at least 11/2 inches high on a white background... red letters at least 1 inch high on a white background at least 2 inches high. These signs may be... marking and locating signs, sources of general cabin illumination, interior lighting in emergency exit...

  14. 14 CFR 25.812 - Emergency lighting.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... sign required by § 25.811(d)(3) must have red letters at least 11/2 inches high on a white background... red letters at least 1 inch high on a white background at least 2 inches high. These signs may be... marking and locating signs, sources of general cabin illumination, interior lighting in emergency exit...

  15. 21 CFR 179.41 - Pulsed light for the treatment of food.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Pulsed light for the treatment of food. 179.41 Section 179.41 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) IRRADIATION IN THE PRODUCTION, PROCESSING AND HANDLING OF FOOD Radiation and Radiation Sources...

  16. A compact high brightness laser synchrotron light source for medical applications

    NASA Astrophysics Data System (ADS)

    Nakajima, Kazuhisa

    1999-07-01

    The present high-brightness hard X-ray sources have been developed as third generation synchrotron light sources based on large high energy electron storage rings and magnetic undulators. Recently availability of compact terawatt lasers arouses a great interest in the use of lasers as undulators. The laser undulator concept makes it possible to construct an attractive compact synchrotron radiation source which has been proposed as a laser synchrotron light source. This paper proposes a compact laser synchrotron light source for mediacal applications, such as an intravenous coronary angiography and microbeam therapy.

  17. An inexpensive Arduino-based LED stimulator system for vision research.

    PubMed

    Teikari, Petteri; Najjar, Raymond P; Malkki, Hemi; Knoblauch, Kenneth; Dumortier, Dominique; Gronfier, Claude; Cooper, Howard M

    2012-11-15

    Light emitting diodes (LEDs) are being used increasingly as light sources in life sciences applications such as in vision research, fluorescence microscopy and in brain-computer interfacing. Here we present an inexpensive but effective visual stimulator based on light emitting diodes (LEDs) and open-source Arduino microcontroller prototyping platform. The main design goal of our system was to use off-the-shelf and open-source components as much as possible, and to reduce design complexity allowing use of the system to end-users without advanced electronics skills. The main core of the system is a USB-connected Arduino microcontroller platform designed initially with a specific emphasis on the ease-of-use creating interactive physical computing environments. The pulse-width modulation (PWM) signal of Arduino was used to drive LEDs allowing linear light intensity control. The visual stimulator was demonstrated in applications such as murine pupillometry, rodent models for cognitive research, and heterochromatic flicker photometry in human psychophysics. These examples illustrate some of the possible applications that can be easily implemented and that are advantageous for students, educational purposes and universities with limited resources. The LED stimulator system was developed as an open-source project. Software interface was developed using Python with simplified examples provided for Matlab and LabVIEW. Source code and hardware information are distributed under the GNU General Public Licence (GPL, version 3). Copyright © 2012 Elsevier B.V. All rights reserved.

  18. The Use of Light-Emitting Diodes (LEDs) as Green and Red/Far-Red Light Sources in Plant Physiology.

    ERIC Educational Resources Information Center

    Jackson, David L.; And Others

    1985-01-01

    The use of green, red, and far-red light-emitting diodes (LEDs) as light sources for plant physiological studies is outlined and evaluated. Indicates that LED lamps have the advantage over conventional light sources in that they are lightweight, low-cost, portable, easily constructed, and do not require color filters. (Author/DH)

  19. Light Source

    NASA Technical Reports Server (NTRS)

    1993-01-01

    Research on food growth for long duration spacecraft has resulted in a light source for growing plants indoors known as Qbeam, a solid state light source consisting of a control unit and lamp. The light source, manufactured by Quantum Devices, Inc., is not very hot, although it generates high intensity radiation. When Ron Ignatius, an industrial partner of WCSAR, realized that terrestrial plant research lighting was not energy efficient enough for space use, he and WCSAR began to experiment with light emitting diodes. A line of LED products was developed, and QDI was formed to market the technology. An LED-based cancer treatment device is currently under development.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riza, Nabeel Agha; Perez, Frank

    A remote temperature sensing system includes a light source selectively producing light at two different wavelengths and a sensor device having an optical path length that varies as a function of temperature. The sensor receives light emitted by the light source and redirects the light along the optical path length. The system also includes a detector receiving redirected light from the sensor device and generating respective signals indicative of respective intensities of received redirected light corresponding to respective wavelengths of light emitted by the light source. The system also includes a processor processing the signals generated by the detector tomore » calculate a temperature of the device.« less

  1. High solar-light photocatalytic activity of using Cu3Se2/rGO nanocomposites synthesized by a green co-precipitation method

    NASA Astrophysics Data System (ADS)

    Nouri, Morteza; Saray, Abdolali Moghaddam; Azimi, H. R.; Yousefi, Ramin

    2017-11-01

    Current work presents a facile, cost-effective, and green method to synthesize copper selenide nanostructures and copper selenide/graphene nanocomposites. The products were synthesized by a co-precipitation method by glycine amino acid as a green surfactant and graphene oxide (GO) sheets as a graphene source. X-ray diffraction patterns (XRD) of the products indicated that the products were Cu2Se3 with tetragonal phase. Fourier transform infrared (FTIR) spectroscopy and the XRD patterns indicated that the GO sheets were changed into reduced GO (rGO) during the synthesis process. Scanning and transmission electron microscopy (SEM and TEM) images showed the nanoparticles (NPs) that were decorated on rGO sheets had the significantly smaller size in compared to the pristine NPs. UV-vis results revealed that, the absorption peak of the products were in the visible region with a band-gap value between 1.85 eV and 1.95 eV. Finally, the products were applied as photocatalytic materials to remove Methylene Blue (MB) dye under solar-light and visible-light irradiation conditions. It was observed; the rGO had a significant role in enhancing the photocatalytic performance of the products and Cu2Se3/rGO (15%) could degrade more than 91% and 73% of MB only during 1 h under solar-light and visible-light sources, respectively.

  2. Vacuum-Compatible Wideband White Light and Laser Combiner Source System

    NASA Technical Reports Server (NTRS)

    Azizi, Alineza; Ryan, Daniel J.; Tang, Hong; Demers, Richard T.; Kadogawa, Hiroshi; An, Xin; Sun, George Y.

    2010-01-01

    For the Space Interferometry Mission (SIM) Spectrum Calibration Development Unit (SCDU) testbed, wideband white light is used to simulate starlight. The white light source mount requires extremely stable pointing accuracy (<3.2 microradians). To meet this and other needs, the laser light from a single-mode fiber was combined, through a beam splitter window with special coating from broadband wavelengths, with light from multimode fiber. Both lights were coupled to a photonic crystal fiber (PCF). In many optical systems, simulating a point star with broadband spectrum with stability of microradians for white light interferometry is a challenge. In this case, the cameras use the white light interference to balance two optical paths, and to maintain close tracking. In order to coarse align the optical paths, a laser light is sent into the system to allow tracking of fringes because a narrow band laser has a great range of interference. The design requirements forced the innovators to use a new type of optical fiber, and to take a large amount of care in aligning the input sources. The testbed required better than 1% throughput, or enough output power on the lowest spectrum to be detectable by the CCD camera (6 nW at camera). The system needed to be vacuum-compatible and to have the capability for combining a visible laser light at any time for calibration purposes. The red laser is a commercially produced 635-nm laser 5-mW diode, and the white light source is a commercially produced tungsten halogen lamp that gives a broad spectrum of about 525 to 800 nm full width at half maximum (FWHM), with about 1.4 mW of power at 630 nm. A custom-made beam splitter window with special coating for broadband wavelengths is used with the white light input via a 50-mm multi-mode fiber. The large mode area PCF is an LMA-8 made by Crystal Fibre (core diameter of 8.5 mm, mode field diameter of 6 mm, and numerical aperture at 625 nm of 0.083). Any science interferometer that needs a tracking laser fringe to assist in alignment can use this system.

  3. Illumination control apparatus for compensating solar light

    NASA Technical Reports Server (NTRS)

    Owens, L. J. (Inventor)

    1978-01-01

    An illumination control apparatus is presented for supplementing light from solar radiation with light from an artificial light source to compensate for periods of insufficient levels of solar light. The apparatus maintains a desired illumination level within an interior space comprising an artificial light source connected to an electrical power source with a switch means for selectively energizing said light source. An actuator means for controlling the on-off operation of the switch means is connected to a light sensor which responses to the illumination level of the interior space. A limit switch carried adjacent to the actuator limits the movement of the actuator within a predetermined range so as to prevent further movement thereof during detection of erroneous illumination conditions.

  4. Distribution of Monochrome Screen Luminance in the CTOL Visual Technology Research Simulator.

    DTIC Science & Technology

    1980-11-01

    runway lines 3.8 4.2 8. Carrier runway 2.5 3.5 9. FLOLS* Meatball ** 2.0 2.4 10. FLOLS Background 0.68 1.3 *Fresnal Lens Optical Landing System...Standard U.S. Navy carrier optical landing device). ** Meatball is the light source of the FLOLS which the pilot uses for glideslope information in a carrier...LANDING DISPLAY FOV (Foot Lamberts) 1. Carrier Deck Runway Lighting 1.5 2. Carrier Runway Area 0.048 3. FLOLS Meatball 0.6 Figure 5 also shows the

  5. White light generation via up-conversion and blue tone in Er3+/Tm3+/Yb3+-doped zinc-tellurite glasses

    NASA Astrophysics Data System (ADS)

    Rivera, V. A. G.; Ferri, F. A.; Nunes, L. A. O.; Marega, E.

    2017-05-01

    Yb3+, Er3+ and Tm3+ triply doped zinc-tellurite glass have been prepared containing up to 3.23 wt% of rare-earth ion oxides, were characterized by absorption spectroscopy, excitation, emission and up-conversion spectra. Transparent and homogeneous glasses have been produced, managing the red, green and blue emission bands, in order to generate white light considering the human eye perception. The energy transfer (resonant or non-resonant) between those rare-earth ions provides a color balancing mechanism that maintains the operating point in the white region, generating warm white light, cool white light and artificial daylight through the increase of the 976/980 nm diode laser excitation power from 4 to 470 mW. A light source at 4000 K is obtained under the excitation at 980 nm with 15 mW, providing a white light environment that is comfortable to the human eye vision. The spectroscopic study presented in this work describes the white light generation by the triply-doped zinc-tellurite glass, ranging from blue, green and red, by controlling the laser excitation power and wavelength at 976/980 nm. Such white tuning provokes healthy effects on human health throughout the day, especially the circadian system.

  6. A Small-Scale 3D Imaging Platform for Algorithm Performance Evaluation

    DTIC Science & Technology

    2007-06-01

    between their acquisitions will form the basis for stereo analysis , and thus a 3D perception of the observed scene. Several low cost and economic...incident light versus 2% on a photographic type film [6]. The CCD camera then transforms these patterns of light into electrical signals. First...sources of lux or illumination. Table 1: Lux (Illumination) Quantitative Comparisons. Luminance Example 0.00005 lux Starlight 1 lux Moonlight 10

  7. Fiber-optic voltage measuring system

    NASA Astrophysics Data System (ADS)

    Ye, Miaoyuan; Nie, De-Xin; Li, Yan; Peng, Yu; Lin, Qi-Qing; Wang, Jing-Gang

    1993-09-01

    A new fibre optic voltage measuring system has been developed based on the electrooptic effect of bismuth germanium oxide (Bi4Ge3O12)crystal. It uses the LED as the light source. The light beam emitted from the light source is transmitted to the sensor through the optic fibre and the intensity of the output beam is changed by the applied voltage. This optic signal is transmitted to the PIN detector and converted to an electric signal which is processed by the electronic circuit and 8098 single chip microcomputer the output voltage signal obtained is directly proportional to the applied voltage. This paper describes the principle the configuration and the performance parameters of the system. Test results are evaluated and discussed.

  8. Food contact surfaces coated with nitrogen-doped titanium dioxide: effect on Listeria monocytogenes survival under different light sources

    NASA Astrophysics Data System (ADS)

    Rodrigues, D.; Teixeira, P.; Tavares, C. J.; Azeredo, J.

    2013-04-01

    Improvement of food safety is a very important issue, and is on the basis of production and application of new/modified food contact surfaces. Titanium dioxide (TiO2) and, more recently, nitrogen-doped titanium dioxide (N-TiO2) coatings are among the possible forms to enhance food contact surfaces performance in terms of higher hygiene and easier sanitation. In this context, the present work aimed at evaluating the bactericidal activity of an N-TiO2 coating on glass and stainless steel under two different sources of visible light - fluorescent and incandescent - and ultraviolet (UV) irradiation. Listeria monocytogenes was chosen as representative of major foodborne pathogens and its survival was tested on N-TiO2 coated coupons. In terms of survival percentage, good results were obtained after exposure of coated surfaces to all light types since, apart from the value obtained after exposing glass to fluorescent light (56.3%), survival rates were always below 50%. However, no effective disinfection was obtained, given that for a disinfectant or sanitizing agent to be claimed as effective it needs to be able to promote at least a 3-log reduction of the microbial load, which was not observed for any of the experimental conditions assessed. Even so, UV irradiation was the most successful on eliminating cells on coated surfaces, since the amount of bacteria was reduced to 1.49 × 106 CFU/ml on glass and 2.37 × 107 on stainless steel. In contrast, both visible light sources had only slightly decreased the amount of viable cells, which remained in the range of 8 log CFU/ml. Hence, although some bactericidal effect was accomplished under visible light, UV was the most effective light source on promoting photocatalytic reactions on N-TiO2 coated coupons and none of the experimental conditions have reached a satisfactory disinfection level. Thus, this surface coating needs further research and improvement in order to become truly effective against foodborne pathogens and, ultimately, become a useful tool towards food safety in general.

  9. A numerical experiment on light pollution from distant sources

    NASA Astrophysics Data System (ADS)

    Kocifaj, M.

    2011-08-01

    To predict the light pollution of the night-time sky realistically over any location or measuring point on the ground presents quite a difficult calculation task. Light pollution of the local atmosphere is caused by stray light, light loss or reflection of artificially illuminated ground objects or surfaces such as streets, advertisement boards or building interiors. Thus it depends on the size, shape, spatial distribution, radiative pattern and spectral characteristics of many neighbouring light sources. The actual state of the atmospheric environment and the orography of the surrounding terrain are also relevant. All of these factors together influence the spectral sky radiance/luminance in a complex manner. Knowledge of the directional behaviour of light pollution is especially important for the correct interpretation of astronomical observations. From a mathematical point of view, the light noise or veil luminance of a specific sky element is given by a superposition of scattered light beams. Theoretical models that simulate light pollution typically take into account all ground-based light sources, thus imposing great requirements on CPU and MEM. As shown in this paper, a contribution of distant sources to the light pollution might be essential under specific conditions of low turbidity and/or Garstang-like radiative patterns. To evaluate the convergence of the theoretical model, numerical experiments are made for different light sources, spectral bands and atmospheric conditions. It is shown that in the worst case the integration limit is approximately 100 km, but it can be significantly shortened for light sources with cosine-like radiative patterns.

  10. The Impact of Environmental Light Intensity on Experimental Tumor Growth.

    PubMed

    Suckow, Mark A; Wolter, William R; Duffield, Giles E

    2017-09-01

    Cancer research requires for consistent models that minimize environmental variables. Within the typical laboratory animal housing facility, animals may be exposed to varying intensities of light as a result of cage type, cage position, light source, and other factors; however, studies evaluating the differential effect of light intensity during the light phase on tumor growth are lacking. The effect of cage face light intensity, as determined by cage rack position was evaluated with two tumor models using the C57Bl/6NHsd mouse and transplantable B16F10 melanoma cells or Lewis lung carcinoma (LLC) cells. Animals were housed in individually-ventilated cages placed at the top, middle, or bottom of the rack in a diagonal pattern so that the top cage was closest to the ceiling light source, and cage face light intensity was measured. Following a two-week acclimation period at the assigned cage position, animals were subcutaneously administered either 1.3×10 6 B16F10 melanoma cells or 2.5×10 5 Lewis lung carcinoma cells. Weights of excised tumors were measured following euthanasia 18 days (melanoma) or 21 days (LCC) after tumor cell administration. Cage face light intensity was significantly different depending on the location of the cage, with cages closest to the light source have the greatest intensity. Mean tumor weights were significantly less (p<0.001 for melanoma; p≤0.01 for LCC) in middle light intensity mice compared to high and low light intensity mice. The environmental light intensity to which experimental animals are exposed may vary markedly with cage location and can significantly influence experimental tumor growth, thus supporting the idea that light intensity should be controlled as an experimental variable for animals used in cancer research. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  11. Study on method to simulate light propagation on tissue with characteristics of radial-beam LED based on Monte-Carlo method.

    PubMed

    Song, Sangha; Elgezua, Inko; Kobayashi, Yo; Fujie, Masakatsu G

    2013-01-01

    In biomedical, Monte-carlo simulation is commonly used for simulation of light diffusion in tissue. But, most of previous studies did not consider a radial beam LED as light source. Therefore, we considered characteristics of a radial beam LED and applied them on MC simulation as light source. In this paper, we consider 3 characteristics of radial beam LED. The first is an initial launch area of photons. The second is an incident angle of a photon at an initial photon launching area. The third is the refraction effect according to contact area between LED and a turbid medium. For the verification of the MC simulation, we compared simulation and experimental results. The average of the correlation coefficient between simulation and experimental results is 0.9954. Through this study, we show an effective method to simulate light diffusion on tissue with characteristics for radial beam LED based on MC simulation.

  12. Long lifetime, low intensity light source for use in nighttime viewing of equipment maps and other writings

    DOEpatents

    Frank, Alan M.; Edwards, William R.

    1983-01-01

    A long-lifetime light source with sufficiently low intensity to be used for reading a map or other writing at nighttime, while not obscuring the user's normal night vision. This light source includes a diode electrically connected in series with a small power source and a lens properly positioned to focus at least a portion of the light produced by the diode.

  13. Lumen degradation analysis of LED lamps based on the subsystem isolation method.

    PubMed

    Ke, Hong-Liang; Hao, Jian; Tu, Jian-Hui; Miao, Pei-Xian; Wang, Chao-Quan; Cui, Jing-Zhong; Sun, Qiang; Sun, Ren-Tao

    2018-02-01

    The lumen degradation of LED lamps undergoing an accelerated aging test is investigated. The entire LED lamp is divided into three subsystems, namely, driver, lampshade, and LED light source. The parameters of output power [Watts (W)], transmittance (%), and lumen flux (lm) are adopted in the analysis of the degradation of the driver, lampshade, and LED light source, respectively. Two groups of LED lamps are aged under the ambient temperatures of 25°C and 85°C, respectively, with the aging time of 2000 h. The lumen degradation of the lamps is from 3.8% to 4.9% for the group under a temperature of 25°C and from 10.6% to 12.7% for the group under a temperature of 85°C. The LED light source is the most aggressive part of the three subsystems, which accounts for 70.5% of the lumen degradation of the LED lamp on average. The lampshade is the second degradation source, which causes 21.5% of the total amount on average. The driver is the third degradation source, which causes 6.5% under 25°C and 2.8% under 85°C of the total amount on average.

  14. Particulate matter (PM) concentrations in underground and ground-level rail systems of the Los Angeles Metro

    NASA Astrophysics Data System (ADS)

    Kam, Winnie; Cheung, Kalam; Daher, Nancy; Sioutas, Constantinos

    2011-03-01

    Elevated concentrations of particulate matter (PM) have been found in a number of worldwide underground transit systems, with major implications regarding exposure of commuters to PM and its associated health effects. An extensive sampling campaign was conducted in May-August 2010 to measure PM concentrations in two lines of the Los Angeles Metro system - an underground subway line (Metro red line) and a ground-level light-rail line (Metro gold line). The campaign goals were to: 1) determine personal PM exposure of commuters of both lines, and 2) measure and compare PM concentrations at station platforms and inside the train. Considering that a commuter typically spent 75% of time inside the train and 25% of time waiting at a station, subway commuters were exposed on average to PM 10 and PM 2.5 concentrations that were 1.9 and 1.8 times greater than the light-rail commuters. The average PM 10 concentrations for the subway line at station platforms and inside the train were 78.0 μg m -3 and 31.5 μg m -3, respectively; for the light-rail line, corresponding PM 10 concentrations were 38.2 μg m -3 and 16.2 μg m -3. Regression analysis demonstrated that personal exposure concentrations for the light-rail line are strongly associated with ambient PM levels ( R2 = 0.61), while PM concentrations for the subway line are less influenced by ambient conditions ( R2 = 0.38) and have a relatively stable background level of about 21 μg m -3. Our findings suggest that local emissions (i.e., vehicular traffic, road dust) are the main source of airborne PM for the light-rail line. The subway line, on the other hand, has an additional source of PM, most likely generated from the daily operation of trains. Strong inter-correlation of PM 10 between the train and station microenvironments shows that airborne PM at stations are the main source of PM inside the trains for both lines ( R2 = 0.91 and 0.81 for subway and light-rail line, respectively). In addition, PM 2.5 and coarse PM (PM 10-2.5) are also strongly correlated for the subway line ( R2 = 0.89) and the light-rail line ( R2 = 0.52-0.92), suggesting that PM 2.5 and coarse PM originate from a common source. Finally, in comparison to worldwide subway systems, the L.A. Metro system is relatively 'clean'. Since the system is comparatively new (in operation since 1993), its ventilation system and braking technology are probably more efficient and more advanced than older subway systems.

  15. Enhanced photoluminescence intensity by modifying the surface nanostructure of Nd3+-doped (Pb, La)(Zr, Ti)O3 ceramics.

    PubMed

    Xu, Long; Zhang, Jingwen; Zhao, Hua; Sun, Haibin; Xu, Caixia

    2017-09-01

    Quasi-period cylindrical nanostructures with both diameters and intervals of about 100 nm are manufactured on the surfaces of Nd 3+ -doped lanthanum lead zirconate titanate ceramics by femtosecond laser irradiation under SF 6 atmosphere. A light-emission enhancement of more than 20 times is investigated, accompanied by an extremely long trailing-off time of light emission and lower threshold. A specific polarization state of the light emission is achieved and tuned by changing the incident regions of the pumping source. The increased absorption coefficient of the specimen is discussed based on multiple scattering and weak localization of light. In addition, both the scatterers provided by the laser-machined nanostructure and the recurrent photoinduced trapping and re-excitation process participated in the enhancement of the light emission. This Letter offers new insight to improve the luminescence property of laser materials, as well as to broaden the range of exploring the weak localization of light and random lasers.

  16. Collimating lens for light-emitting-diode light source based on non-imaging optics.

    PubMed

    Wang, Guangzhen; Wang, Lili; Li, Fuli; Zhang, Gongjian

    2012-04-10

    A collimating lens for a light-emitting-diode (LED) light source is an essential device widely used in lighting engineering. Lens surfaces are calculated by geometrical optics and nonimaging optics. This design progress does not rely on any software optimization and any complex iterative process. This method can be used for any type of light source not only Lambertian. The theoretical model is based on point source. But the practical LED source has a certain size. So in the simulation, an LED chip whose size is 1 mm*1 mm is used to verify the feasibility of the model. The mean results show that the lenses have a very compact structure and good collimating performance. Efficiency is defined as the ratio of the flux in the illuminated plane to the flux from LED source without considering the lens material transmission. Just investigating the loss in the designed lens surfaces, the two types of lenses have high efficiencies of more than 90% and 99%, respectively. Most lighting area (possessing 80% flux) radii are no more than 5 m when the illuminated plane is 200 m away from the light source.

  17. The Swift/BAT Hard X-ray Transient Monitor

    NASA Technical Reports Server (NTRS)

    Krimm, H. A.; Holland, S. T.; Corbet, R.H.D.; Pearlman, A. B.; Romano, P.; Kennea, J. A.; Bloom, J. S.; Barthelmy, S. D.; Baumgartner, W. H.; Cummings, J. R.; hide

    2013-01-01

    The Swift/Burst Alert Telescope (BAT) hard X-ray transient monitor provides near real-time coverage of the X-ray sky in the energy range 15-50 keV. The BAT observes 88% of the sky each day with a detection sensitivity of 5.3 mCrab for a full-day observation and a time resolution as ne as 64 seconds. The three main purposes of the monitor are (1) the discovery of new transient X-ray sources, (2) the detection of outbursts or other changes in the ux of known X-ray sources, and (3) the generation of light curves of more than 900 sources spanning over eight years. The primary interface for the BAT transient monitor is a public web page. Since 2005 February, 242 sources have been detected in the monitor, 149 of them persistent and 93 detected only in outburst. Among these sources, 16 were previously unknown and discovered in the transient monitor. In this paper, we discuss the methodology and the data processing and ltering for the BAT transient monitor and review its sensitivity and exposure. We provide a summary of the source detections and classify them according to the variability of their light curves. Finally, we review all new BAT monitor discoveries and present basic data analysis and interpretations for those sources with previously unpublished results.

  18. Geochemical characteristics and reservoir continuity of Silurian Acacus in Ghadames Basin, Southern Tunisia

    NASA Astrophysics Data System (ADS)

    Mahmoudi, S.; Mohamed, A. Belhaj; Saidi, M.; Rezgui, F.

    2017-11-01

    The present work is dealing with the study of lateral and vertical continuity of the multi-layers Acacus reservoir (Ghadames Basin-Southern Tunisia) using the distribution of hydrocarbon fraction. For this purpose, oil-oil and source rock-oil correlations as well as the composition of the light fractions and a number of saturate and aromatic biomarkers parameters, including C35/C34 hopanes and DBT/P, have been investigated. Based on the ratios of light fraction and their fingerprints, the Acacus reservoir from Well1 and Well2 have found to be laterally non-connected although the hydrocarbons they contain have the same source rock. Moreover, the two oil samples from two different Acacus reservoir layers crossed by Well3-A3 and A9, display a similar hydrocarbons distribution, suggesting vertical reservoir continuity. On the other hand, the biomarker distributions of the oils samples and source rocks assess a Silurian ;Hot shale; that is the source rock feeding the Acacus reservoir. The biomarker distribution is characterized by high tricyclic terpanes contents compared to hopanes for the Silurian source rock and the two crude oils. This result is also confirmed by the dendrogram that precludes the Devonian source rocks as a source rock in the study area.

  19. Evaluation of OLED and edge-lit LED lighting panels

    NASA Astrophysics Data System (ADS)

    Mou, Xi; Narendran, Nadarajah; Zhu, Yiting; Freyssinier, Jean Paul

    2016-09-01

    Solid-state lighting (SSL) offers a new technology platform for lighting designers and end-users to illuminate spaces with low energy demand. Two types of SSL sources include organic light-emitting diodes (OLEDs) and light-emitting diodes (LEDs). OLED is an area light source, and its primary competing technology is the edge-lit LED panel. Generally, both of these technologies are considered similar in shape and appearance, but there is little understanding of how people perceive discomfort glare from large area light sources. The objective of this study was to evaluate discomfort glare for the two lighting technologies under similar operating conditions by gathering observers' reactions. The human factors study results showed no statistically significant difference in human response to discomfort glare between OLED and edge-lit LED panels when the two light sources produced the same lighting stimulus. This means both technologies appeared equally glary beyond a certain luminance.

  20. Design of optical transmitting antenna with enhance performance in visible light communication

    NASA Astrophysics Data System (ADS)

    Kuang, Dang; Wang, Jianping; Lu, Huimin

    2016-10-01

    An optical transmitting antenna for visible light communication(VLC) is designed in this work, in which the antenna is positioned before the light-emitting diodes (LED) source to change the lighting distribution, in order to achieve uniform received power effect. The method to design antenna is introduced into physical optical lens principle. According to the energy conservation law and Snell law, the antenna is designed via establishing energy mapping between the luminous flux emitted by a LED source with Lambertian distribution and the target plane. The coordinates of the antenna model are obtained under matrix laboratory (MATLAB). The antenna model entity is generated through three dimensional (3D) composition software AutoCAD with the coordinates of antenna. Ray-tracing software Tracepro is used to trace the ray which through antenna, and validate the irradiance maps. The uniformity of illumination and received power of the designed VLC is improved from approximately 35% to over 83%.

Top