Sample records for specific diagnostic tools

  1. The development of a quality appraisal tool for studies of diagnostic reliability (QAREL).

    PubMed

    Lucas, Nicholas P; Macaskill, Petra; Irwig, Les; Bogduk, Nikolai

    2010-08-01

    In systematic reviews of the reliability of diagnostic tests, no quality assessment tool has been used consistently. The aim of this study was to develop a specific quality appraisal tool for studies of diagnostic reliability. Key principles for the quality of studies of diagnostic reliability were identified with reference to epidemiologic principles, existing quality appraisal checklists, and the Standards for Reporting of Diagnostic Accuracy (STARD) and Quality Assessment of Diagnostic Accuracy Studies (QUADAS) resources. Specific items that encompassed each of the principles were developed. Experts in diagnostic research provided feedback on the items that were to form the appraisal tool. This process was iterative and continued until consensus among experts was reached. The Quality Appraisal of Reliability Studies (QAREL) checklist includes 11 items that explore seven principles. Items cover the spectrum of subjects, spectrum of examiners, examiner blinding, order effects of examination, suitability of the time interval among repeated measurements, appropriate test application and interpretation, and appropriate statistical analysis. QAREL has been developed as a specific quality appraisal tool for studies of diagnostic reliability. The reliability of this tool in different contexts needs to be evaluated. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  2. Lessons learned developing a diagnostic tool for HIV-associated dementia feasible to implement in resource-limited settings: pilot testing in Kenya.

    PubMed

    Kwasa, Judith; Cettomai, Deanna; Lwanya, Edwin; Osiemo, Dennis; Oyaro, Patrick; Birbeck, Gretchen L; Price, Richard W; Bukusi, Elizabeth A; Cohen, Craig R; Meyer, Ana-Claire L

    2012-01-01

    To conduct a preliminary evaluation of the utility and reliability of a diagnostic tool for HIV-associated dementia (HAD) for use by primary health care workers (HCW) which would be feasible to implement in resource-limited settings. In resource-limited settings, HAD is an indication for anti-retroviral therapy regardless of CD4 T-cell count. Anti-retroviral therapy, the treatment for HAD, is now increasingly available in resource-limited settings. Nonetheless, HAD remains under-diagnosed likely because of limited clinical expertise and availability of diagnostic tests. Thus, a simple diagnostic tool which is practical to implement in resource-limited settings is an urgent need. A convenience sample of 30 HIV-infected outpatients was enrolled in Western Kenya. We assessed the sensitivity and specificity of a diagnostic tool for HAD as administered by a primary HCW. This was compared to an expert clinical assessment which included examination by a physician, neuropsychological testing, and in selected cases, brain imaging. Agreement between HCW and an expert examiner on certain tool components was measured using Kappa statistic. The sample was 57% male, mean age was 38.6 years, mean CD4 T-cell count was 323 cells/µL, and 54% had less than a secondary school education. Six (20%) of the subjects were diagnosed with HAD by expert clinical assessment. The diagnostic tool was 63% sensitive and 67% specific for HAD. Agreement between HCW and expert examiners was poor for many individual items of the diagnostic tool (K = .03-.65). This diagnostic tool had moderate sensitivity and specificity for HAD. However, reliability was poor, suggesting that substantial training and formal evaluations of training adequacy will be critical to enable HCW to reliably administer a brief diagnostic tool for HAD.

  3. Diagnostic test accuracy of nutritional tools used to identify undernutrition in patients with colorectal cancer: a systematic review.

    PubMed

    Håkonsen, Sasja Jul; Pedersen, Preben Ulrich; Bath-Hextall, Fiona; Kirkpatrick, Pamela

    2015-05-15

    Effective nutritional screening, nutritional care planning and nutritional support are essential in all settings, and there is no doubt that a health service seeking to increase safety and clinical effectiveness must take nutritional care seriously. Screening and early detection of malnutrition is crucial in identifying patients at nutritional risk. There is a high prevalence of malnutrition in hospitalized patients undergoing treatment for colorectal cancer. To synthesize the best available evidence regarding the diagnostic test accuracy of nutritional tools (sensitivity and specificity) used to identify malnutrition (specifically undernutrition) in patients with colorectal cancer (such as the Malnutrition Screening Tool and Nutritional Risk Index) compared to reference tests (such as the Subjective Global Assessment or Patient Generated Subjective Global Assessment). Patients with colorectal cancer requiring either (or all) surgery, chemotherapy and/or radiotherapy in secondary care. Focus of the review: The diagnostic test accuracy of validated assessment tools/instruments (such as the Malnutrition Screening Tool and Nutritional Risk Index) in the diagnosis of malnutrition (specifically under-nutrition) in patients with colorectal cancer, relative to reference tests (Subjective Global Assessment or Patient Generated Subjective Global Assessment). Types of studies: Diagnostic test accuracy studies regardless of study design. Studies published in English, German, Danish, Swedish and Norwegian were considered for inclusion in this review. Databases were searched from their inception to April 2014. Methodological quality was determined using the Quality Assessment of Diagnostic Accuracy Studies checklist. Data was collected using the data extraction form: the Standards for Reporting Studies of Diagnostic Accuracy checklist for the reporting of studies of diagnostic accuracy. The accuracy of diagnostic tests is presented in terms of sensitivity, specificity, positive and negative predictive values. In addition, the positive likelihood ratio (sensitivity/ [1 - specificity]) and negative likelihood ratio (1 - sensitivity)/ specificity), were also calculated and presented in this review to provide information about the likelihood that a given test result would be expected when the target condition is present compared with the likelihood that the same result would be expected when the condition is absent. Not all trials reported true positive, true negative, false positive and false negative rates, therefore these rates were calculated based on the data in the published papers. A two-by-two truth table was reconstructed for each study, and sensitivity, specificity, positive predictive value, negative predictive value positive likelihood ratio and negative likelihood ratio were calculated for each study. A summary receiver operator characteristics curve was constructed to determine the relationship between sensitivity and specificity, and the area under the summary receiver operator characteristics curve which measured the usefulness of a test was calculated. Meta-analysis was not considered appropriate, therefore data was synthesized in a narrative summary. 1. One study evaluated the Malnutrition Screening Tool against the reference standard Patient-Generated Subjective Global Assessment. The sensitivity was 56% and the specificity 84%. The positive likelihood ratio was 3.100, negative likelihood ratio was 0.59, the diagnostic odds ratio (CI 95%) was 5.20 (1.09-24.90) and the Area Under the Curve (AUC) represents only a poor to fair diagnostic test accuracy. A total of two studies evaluated the diagnostic accuracy of Malnutrition Universal Screening Tool (MUST) (index test) compared to both Subjective Global Assessment (SGA) (reference standard) and PG-SGA (reference standard) in patients with colorectal cancer. In MUST vs SGA the sensitivity of the tool was 96%, specificity was 75%, LR+ 3.826, LR- 0.058, diagnostic OR (CI 95%) 66.00 (6.61-659.24) and AUC represented excellent diagnostic accuracy. In MUST vs PG-SGA the sensitivity of the tool was 72%, specificity 48.9%, LR+ 1.382, LR- 0.579, diagnostic OR (CI 95%) 2.39 (0.87-6.58) and AUC indicated that the tool failed as a diagnostic test to identify patients with colorectal cancer at nutritional risk,. The Nutrition Risk Index (NRI) was compared to SGA representing a sensitivity of 95.2%, specificity of 62.5%, LR+ 2.521, LR- 0.087, diagnostic OR (CI 95%) 28.89 (6.93-120.40) and AUC represented good diagnostic accuracy. In regard to NRI vs PG-SGA the sensitivity of the tool was 68%, specificity 64%, LR+ 1.947, LR- 0.487, diagnostic OR (CI 95%) 4.00 (1.23-13.01) and AUC indicated poor diagnostic test accuracy. There are no single, specific tools used to screen or assess the nutritional status of colorectal cancer patients. All tools showed varied diagnostic accuracies when compared to the reference standards SGA and PG-SGA. Hence clinical judgment combined with perhaps the SGA or PG-SGA should play a major role. The PG-SGA offers several advantages over the SGA tool: 1) the patient completes the medical history component, thereby decreasing the amount of time involved; 2) it contains more nutrition impact symptoms, which are important to the patient with cancer; and 3) it has a scoring system that allows patients to be triaged for nutritional intervention. Therefore, the PG-SGA could be used as a nutrition assessment tool as it allows quick identification and prioritization of colorectal cancer patients with malnutrition in combination with other parameters. This systematic review highlights the need for the following: Further studies needs to investigate the diagnostic accuracy of already existing nutritional screening tools in the context of colorectal cancer patients. If new screenings tools are developed, they should be developed and validated in the specific clinical context within the same patient population (colorectal cancer patients). The Joanna Briggs Institute.

  4. Quality Assessment of Comparative Diagnostic Accuracy Studies: Our Experience Using a Modified Version of the QUADAS-2 Tool

    ERIC Educational Resources Information Center

    Wade, Ros; Corbett, Mark; Eastwood, Alison

    2013-01-01

    Assessing the quality of included studies is a vital step in undertaking a systematic review. The recently revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool (QUADAS-2), which is the only validated quality assessment tool for diagnostic accuracy studies, does not include specific criteria for assessing comparative studies. As…

  5. DIAGNOSTIC TOOL DEVELOPMENT AND APPLICATION THROUGH REGIONAL CASE STUDIES

    EPA Science Inventory

    Case studies are a useful vehicle for developing and testing conceptual models, classification systems, diagnostic tools and models, and stressor-response relationships. Furthermore, case studies focused on specific places or issues of interest to the Agency provide an excellent ...

  6. Case Report: SPECT/CT as the New Diagnostic Tool for Specific Wrist Pathology.

    PubMed

    Linde, Musters; Ten Broek, M; Kraan, G A

    2017-01-01

    Single photon emission computed tomography has been introduced as a promising new diagnostic tool in orthopaedic pathology since the early 90'. Computed tomography, the combined with SPECT, gives insight in the specific sight of wrist pathology. Literature already supports introduction of SPECT/CT in wrist pathology, but clinical application is lagging. A 40yr old patient reported first in 2004 with persisting pain after a right distal radius fracture. Several diagnostics and operative interventions were performed, all unsuccessful. Because of the persisting pain a SPECT-CT was performed which showed a cyst in the hamate bone, which was successfully enucleated. The patient was finally pain free at recent follow-up. With a QDash-score of 43 and a PRW (H) E-DLV-score of 58/150. In this case report, SPECT/CT proved a very sensitive diagnostic tool for specific pathology of the wrist. It offered precise localisation and thereby the clinically suspected diagnosis was confirmed and the patient successfully treated.

  7. Assessing Disease Class-Specific Diagnostic Ability: A Practical Adaptive Test Approach.

    ERIC Educational Resources Information Center

    Papa, Frank J.; Schumacker, Randall E.

    Measures of the robustness of disease class-specific diagnostic concepts could play a central role in training programs designed to assure the development of diagnostic competence. In the pilot study, the authors used disease/sign-symptom conditional probability estimates, Monte Carlo procedures, and artificial intelligence (AI) tools to create…

  8. A Quasi-Universal Nonword Repetition Task as a Diagnostic Tool for Bilingual Children Learning Dutch as a Second Language

    ERIC Educational Resources Information Center

    Boerma, Tessel; Chiat, Shula; Leseman, Paul; Timmermeister, Mona; Wijnen, Frank; Blom, Elma

    2015-01-01

    Purpose: This study evaluated a newly developed quasi-universal nonword repetition task (Q-U NWRT) as a diagnostic tool for bilingual children with language impairment (LI) who have Dutch as a 2nd language. The Q-U NWRT was designed to be minimally influenced by knowledge of 1 specific language in contrast to a language-specific NWRT with which it…

  9. Evaluating radiographers' diagnostic accuracy in screen-reading mammograms: what constitutes a quality study?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Debono, Josephine C, E-mail: josephine.debono@bci.org.au; Poulos, Ann E; Westmead Breast Cancer Institute, Westmead, New South Wales

    The aim of this study was to first evaluate the quality of studies investigating the diagnostic accuracy of radiographers as mammogram screen-readers and then to develop an adapted tool for determining the quality of screen-reading studies. A literature search was used to identify relevant studies and a quality evaluation tool constructed by combining the criteria for quality of Whiting, Rutjes, Dinnes et al. and Brealey and Westwood. This constructed tool was then applied to the studies and subsequently adapted specifically for use in evaluating quality in studies investigating diagnostic accuracy of screen-readers. Eleven studies were identified and the constructed toolmore » applied to evaluate quality. This evaluation resulted in the identification of quality issues with the studies such as potential for bias, applicability of results, study conduct, reporting of the study and observer characteristics. An assessment of the applicability and relevance of the tool for this area of research resulted in adaptations to the criteria and the development of a tool specifically for evaluating diagnostic accuracy in screen-reading. This tool, with further refinement and rigorous validation can make a significant contribution to promoting well-designed studies in this important area of research and practice.« less

  10. Prostate cancer diagnostics: Clinical challenges and the ongoing need for disruptive and effective diagnostic tools.

    PubMed

    Sharma, Shikha; Zapatero-Rodríguez, Julia; O'Kennedy, Richard

    The increased incidence and the significant health burden associated with carcinoma of the prostate have led to substantial changes in its diagnosis over the past century. Despite technological advancements, the management of prostate cancer has become progressively more complex and controversial for both early and late-stage disease. The limitations and potential harms associated with the use of prostate-specific antigen (PSA) as a diagnostic marker have stimulated significant investigation of numerous novel biomarkers that demonstrate varying capacities to detect prostate cancer and can decrease unnecessary biopsies. However, only a few of these markers have been approved for specific clinical settings while the others have not been adequately validated for use. This review systematically and critically assesses ongoing issues and emerging challenges in the current state of prostate cancer diagnostic tools and the need for disruptive next generation tools based on analysis of combinations of these biomarkers to enhance predictive accuracy which will benefit clinical diagnostics and patient welfare. Copyright © 2016. Published by Elsevier Inc.

  11. Diagnostic tools in ocular allergy.

    PubMed

    Leonardi, A; Doan, S; Fauquert, J L; Bozkurt, B; Allegri, P; Marmouz, F; Rondon, C; Jedrzejczak, M; Hellings, P; Delgado, L; Calder, V

    2017-10-01

    Ocular allergy (OA) includes a group of common and less frequent hypersensitivity disorders frequently misdiagnosed and not properly managed. The diagnosis of OA is usually based on clinical history and signs and symptoms, with the support of in vivo and in vitro tests when identification of the specific allergen is required. To date, no specific test is available for the diagnosis of the whole spectrum of the different forms of OA. The lack of recommendations on diagnosis of OA is considered a medical need not only for allergists but also for ophthalmologists. This position paper aims to provide a comprehensive overview of the currently available tools for diagnosing OA to promote a common nomenclature and procedures to be used by different specialists. Questionnaires, sign and symptom grading scales, tests, and potential biomarkers for OA are reviewed. We also identified several unmet needs in the diagnostic tools to generate interest, increase understanding, and inspire further investigations. Tools, recommendations, and algorithms for the diagnosis of OA are proposed for use by both allergists and ophthalmologists. Several unmet needs in the diagnostic tools should be further improved by specific clinical research in OA. © 2017 EAACI and John Wiley and Sons A/S. Published by John Wiley and Sons Ltd.

  12. An evidence-based diagnostic classification system for low back pain

    PubMed Central

    Vining, Robert; Potocki, Eric; Seidman, Michael; Morgenthal, A. Paige

    2013-01-01

    Introduction: While clinicians generally accept that musculoskeletal low back pain (LBP) can arise from specific tissues, it remains difficult to confirm specific sources. Methods: Based on evidence supported by diagnostic utility studies, doctors of chiropractic functioning as members of a research clinic created a diagnostic classification system, corresponding exam and checklist based on strength of evidence, and in-office efficiency. Results: The diagnostic classification system contains one screening category, two pain categories: Nociceptive, Neuropathic, one functional evaluation category, and one category for unknown or poorly defined diagnoses. Nociceptive and neuropathic pain categories are each divided into 4 subcategories. Conclusion: This article describes and discusses the strength of evidence surrounding diagnostic categories for an in-office, clinical exam and checklist tool for LBP diagnosis. The use of a standardized tool for diagnosing low back pain in clinical and research settings is encouraged. PMID:23997245

  13. Creation of a simple natural language processing tool to support an imaging utilization quality dashboard.

    PubMed

    Swartz, Jordan; Koziatek, Christian; Theobald, Jason; Smith, Silas; Iturrate, Eduardo

    2017-05-01

    Testing for venous thromboembolism (VTE) is associated with cost and risk to patients (e.g. radiation). To assess the appropriateness of imaging utilization at the provider level, it is important to know that provider's diagnostic yield (percentage of tests positive for the diagnostic entity of interest). However, determining diagnostic yield typically requires either time-consuming, manual review of radiology reports or the use of complex and/or proprietary natural language processing software. The objectives of this study were twofold: 1) to develop and implement a simple, user-configurable, and open-source natural language processing tool to classify radiology reports with high accuracy and 2) to use the results of the tool to design a provider-specific VTE imaging dashboard, consisting of both utilization rate and diagnostic yield. Two physicians reviewed a training set of 400 lower extremity ultrasound (UTZ) and computed tomography pulmonary angiogram (CTPA) reports to understand the language used in VTE-positive and VTE-negative reports. The insights from this review informed the arguments to the five modifiable parameters of the NLP tool. A validation set of 2,000 studies was then independently classified by the reviewers and by the tool; the classifications were compared and the performance of the tool was calculated. The tool was highly accurate in classifying the presence and absence of VTE for both the UTZ (sensitivity 95.7%; 95% CI 91.5-99.8, specificity 100%; 95% CI 100-100) and CTPA reports (sensitivity 97.1%; 95% CI 94.3-99.9, specificity 98.6%; 95% CI 97.8-99.4). The diagnostic yield was then calculated at the individual provider level and the imaging dashboard was created. We have created a novel NLP tool designed for users without a background in computer programming, which has been used to classify venous thromboembolism reports with a high degree of accuracy. The tool is open-source and available for download at http://iturrate.com/simpleNLP. Results obtained using this tool can be applied to enhance quality by presenting information about utilization and yield to providers via an imaging dashboard. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. A Quasi-Universal Nonword Repetition Task as a Diagnostic Tool for Bilingual Children Learning Dutch as a Second Language.

    PubMed

    Boerma, Tessel; Chiat, Shula; Leseman, Paul; Timmermeister, Mona; Wijnen, Frank; Blom, Elma

    2015-12-01

    This study evaluated a newly developed quasi-universal nonword repetition task (Q-U NWRT) as a diagnostic tool for bilingual children with language impairment (LI) who have Dutch as a 2nd language. The Q-U NWRT was designed to be minimally influenced by knowledge of 1 specific language in contrast to a language-specific NWRT with which it was compared. One hundred twenty monolingual and bilingual children with and without LI participated (30 per group). A mixed-design analysis of variance was used to investigate the effects of LI and bilingualism on the NWRTs. Receiver operating characteristic analyses were conducted to evaluate the instruments' diagnostic value. Large negative effects of LI were found on both NWRTs, whereas negative effects of bilingualism only occurred on the language-specific NWRT. Both instruments had high clinical accuracy in the monolingual group, but only the Q-U NWRT had high clinical accuracy in the bilingual group. This study indicates that the Q-U NWRT is a promising diagnostic tool to help identify LI in bilingual children learning Dutch as a 2nd language. The instrument was clinically accurate in both a monolingual and bilingual group of children and seems better able to disentangle LI from language disadvantage than more language-specific measures.

  15. Diagnostic value of fecal tumor M2-pyruvate kinase for CRC screening: a systematic review and meta-analysis.

    PubMed

    Li, Rui; Liu, Jianjun; Xue, Huiping; Huang, Gang

    2012-10-15

    The measurement of fecal tumor M2-pyruvate kinase (PKM2), overexpressed in tumor cells, has been proposed as a novel tool for detecting colorectal cancer (CRC). However, the sensitivity and specificity of this test varied among studies. The aim of this meta-analysis was to determine the diagnostic accuracy of fecal PKM2 for CRC and to evaluate its utility in the CRC screening. It was compared to guaiac fecal occult blood test (gFOBT) or immunological fecal occult blood test (iFOBT). Through comprehensive literature search, 10 studies met the inclusion criteria and were included. Summary estimates for sensitivity and specificity were calculated by using the bivariate random effect model. The hierarchical summary receiver operating characteristic curve was also undertaken. The overall sensitivity and specificity of fecal PKM2 for detecting CRC were 79% (95% CI = 75-83%) and 81% (95% CI = 73-87%), respectively. The summary positive predictive value and negative predictive value were 74% (95% CI = 56-87%) and 86% (95% CI = 79-91%), respectively. The pooled diagnostic odds ratio was 16 (95% CI = 10-26). In head-to-head comparison, the diagnostic odds ratio of PKM2 and gFOBT for CRC were 10.167 (95% CI = 5.992-17.250) and 6.557 (95% CI = 3.467-12.403), respectively. The diagnostic odds ratio of PKM2 and iFOBT for CRC were 9.542 (95% CI = 5.893-15.452) and 67.248 (95% CI = 16.194-279.26), respectively. The fecal PKM2 test was a diagnostic tool with moderate sensitivity and specificity for detecting CRC. Its diagnostic efficiency was similar to that of gFOBT. Because of its relatively low specificity and positive predict value, fecal PKM2 was not recommended used alone as a screening tool for CRC. Copyright © 2012 UICC.

  16. Electrochemistry-based Approaches to Low Cost, High Sensitivity, Automated, Multiplexed Protein Immunoassays for Cancer Diagnostics

    PubMed Central

    Dixit, Chandra K.; Kadimisetty, Karteek; Otieno, Brunah A.; Tang, Chi; Malla, Spundana; Krause, Colleen E.; Rusling, James F.

    2015-01-01

    Early detection and reliable diagnostics are keys to effectively design cancer therapies with better prognoses. Simultaneous detection of panels of biomarker proteins holds great promise as a general tool for reliable cancer diagnostics. A major challenge in designing such a panel is to decide upon a coherent group of biomarkers which have higher specificity for a given type of cancer. The second big challenge is to develop test devices to measure these biomarkers quantitatively with high sensitivity and specificity, such that there are no interferences from the complex serum or tissue matrices. Lastly, integrating all these tests into a technology that doesn’t require exclusive training to operate, and can be used at point-of-care (POC) is another potential bottleneck in futuristic cancer diagnostics. In this article, we review electrochemistry-based tools and technologies developed and/or used in our laboratories to construct low-cost microfluidic protein arrays for highly sensitive detection of the panel of cancer-specific biomarkers with high specificity and at the same time have the potential to be translated into a POC. PMID:26525998

  17. Electrochemistry-based approaches to low cost, high sensitivity, automated, multiplexed protein immunoassays for cancer diagnostics.

    PubMed

    Dixit, Chandra K; Kadimisetty, Karteek; Otieno, Brunah A; Tang, Chi; Malla, Spundana; Krause, Colleen E; Rusling, James F

    2016-01-21

    Early detection and reliable diagnostics are keys to effectively design cancer therapies with better prognoses. The simultaneous detection of panels of biomarker proteins holds great promise as a general tool for reliable cancer diagnostics. A major challenge in designing such a panel is to decide upon a coherent group of biomarkers which have higher specificity for a given type of cancer. The second big challenge is to develop test devices to measure these biomarkers quantitatively with high sensitivity and specificity, such that there are no interferences from the complex serum or tissue matrices. Lastly, integrating all these tests into a technology that does not require exclusive training to operate, and can be used at point-of-care (POC) is another potential bottleneck in futuristic cancer diagnostics. In this article, we review electrochemistry-based tools and technologies developed and/or used in our laboratories to construct low-cost microfluidic protein arrays for the highly sensitive detection of a panel of cancer-specific biomarkers with high specificity which at the same time has the potential to be translated into POC applications.

  18. Developing a tool to support diagnostic delivery of dementia.

    PubMed

    Bennett, Claire E; De Boos, Danielle; Moghaddam, Nima G

    2018-01-01

    It is increasingly recognised that there are challenges affecting the current delivery of dementia diagnoses. Steps are required to address this. Current good practice guidelines provide insufficient direction and interventions from other healthcare settings do not appear to fully translate to dementia care settings. This project has taken a sequential two-phase design to developing a tool specific to dementia diagnostic delivery. Interviews with 14 participants explored good diagnostic delivery. Thematic analysis produced key themes (overcoming barriers, navigation of multiple journeys and completing overt and covert tasks) that were used to inform the design of a tool for use by clinicians, patients and companions. The tool was evaluated for acceptability in focused group discussions with 13 participants, which indicated a desire to use the tool and that it could encourage good practice. Adaptations were highlighted and incorporated to improve acceptability. Future research is now required to further evaluate the tool.

  19. Saliva as a diagnostic tool for oral and systemic diseases

    PubMed Central

    Javaid, Mohammad A.; Ahmed, Ahad S.; Durand, Robert; Tran, Simon D.

    2015-01-01

    Early disease detection is not only vital to reduce disease severity and prevent complications, but also critical to increase success rate of therapy. Saliva has been studied extensively as a potential diagnostic tool over the last decade due to its ease and non-invasive accessibility along with its abundance of biomarkers, such as genetic material and proteins. This review will update the clinician on recent advances in salivary biomarkers to diagnose autoimmune diseases (Sjogren's syndrome, cystic fibrosis), cardiovascular diseases, diabetes, HIV, oral cancer, caries and periodontal diseases. Considering their accuracy, efficacy, ease of use and cost effectiveness, salivary diagnostic tests will be available in dental offices. It is expected that the advent of sensitive and specific salivary diagnostic tools and the establishment of defined guidelines and results following rigorous testing will allow salivary diagnostics to be used as chair-side tests for several oral and systemic diseases in the near future. PMID:26937373

  20. Issues in contemporary and potential future molecular diagnostics for dengue.

    PubMed

    Sekaran, Shamala Devi; Soe, Hui Jen

    2017-03-01

    Dengue has been the most common arbovirus infection worldwide with 2.5 billion people living in over 100 endemic tropical and subtropical regions. Due to the high number of asymptomatic cases and the signs and symptoms being rather unspecific, dengue cases are often under-reported and might influence dengue surveillance programs. Therefore, a rapid, easy to use, inexpensive, and highly sensitive and specific diagnostic tool is essential for early and accurate diagnosis to ease the clinical management of patients as well as for the development of new interventions. Areas covered: This report discusses the contemporary dengue diagnostic tool, mainly from the aspect of molecular diagnosis where an overview of several nuclei acid amplification tests has been included. Potential molecular diagnostic tools such as biosensor and microarray are also discussed in this report. Expert commentary: Rapidness and accuracy in terms of sensitivity and specificity is imperative in dengue diagnosis for both clinical management and surveillance of dengue to ensure early treatment and corrective control measures can be carried out. In the next five years it is expected that there will be newer tests developed using not only the lateral flow techniques but more specifically biosensors and nanotechnology. These new technologies will have to be validated with the appropriate number and category of samples and to address the issue of cross-reactivity.

  1. The computerized adaptive diagnostic test for major depressive disorder (CAD-MDD): a screening tool for depression.

    PubMed

    Gibbons, Robert D; Hooker, Giles; Finkelman, Matthew D; Weiss, David J; Pilkonis, Paul A; Frank, Ellen; Moore, Tara; Kupfer, David J

    2013-07-01

    To develop a computerized adaptive diagnostic screening tool for depression that decreases patient and clinician burden and increases sensitivity and specificity for clinician-based DSM-IV diagnosis of major depressive disorder (MDD). 656 individuals with and without minor and major depression were recruited from a psychiatric clinic and a community mental health center and through public announcements (controls without depression). The focus of the study was the development of the Computerized Adaptive Diagnostic Test for Major Depressive Disorder (CAD-MDD) diagnostic screening tool based on a decision-theoretical approach (random forests and decision trees). The item bank consisted of 88 depression scale items drawn from 73 depression measures. Sensitivity and specificity for predicting clinician-based Structured Clinical Interview for DSM-IV Axis I Disorders diagnoses of MDD were the primary outcomes. Diagnostic screening accuracy was then compared to that of the Patient Health Questionnaire-9 (PHQ-9). An average of 4 items per participant was required (maximum of 6 items). Overall sensitivity and specificity were 0.95 and 0.87, respectively. For the PHQ-9, sensitivity was 0.70 and specificity was 0.91. High sensitivity and reasonable specificity for a clinician-based DSM-IV diagnosis of depression can be obtained using an average of 4 adaptively administered self-report items in less than 1 minute. Relative to the currently used PHQ-9, the CAD-MDD dramatically increased sensitivity while maintaining similar specificity. As such, the CAD-MDD will identify more true positives (lower false-negative rate) than the PHQ-9 using half the number of items. Inexpensive (relative to clinical assessment), efficient, and accurate screening of depression in the settings of primary care, psychiatric epidemiology, molecular genetics, and global health are all direct applications of the current system. © Copyright 2013 Physicians Postgraduate Press, Inc.

  2. DNA microarray technology in nutraceutical and food safety.

    PubMed

    Liu-Stratton, Yiwen; Roy, Sashwati; Sen, Chandan K

    2004-04-15

    The quality and quantity of diet is a key determinant of health and disease. Molecular diagnostics may play a key role in food safety related to genetically modified foods, food-borne pathogens and novel nutraceuticals. Functional outcomes in biology are determined, for the most part, by net balance between sets of genes related to the specific outcome in question. The DNA microarray technology offers a new dimension of strength in molecular diagnostics by permitting the simultaneous analysis of large sets of genes. Automation of assay and novel bioinformatics tools make DNA microarrays a robust technology for diagnostics. Since its development a few years ago, this technology has been used for the applications of toxicogenomics, pharmacogenomics, cell biology, and clinical investigations addressing the prevention and intervention of diseases. Optimization of this technology to specifically address food safety is a vast resource that remains to be mined. Efforts to develop diagnostic custom arrays and simplified bioinformatics tools for field use are warranted.

  3. Emerging applications of fluorescence spectroscopy in medical microbiology field.

    PubMed

    Shahzad, Aamir; Köhler, Gottfried; Knapp, Martin; Gaubitzer, Erwin; Puchinger, Martin; Edetsberger, Michael

    2009-11-26

    There are many diagnostic techniques and methods available for diagnosis of medically important microorganisms like bacteria, viruses, fungi and parasites. But, almost all these techniques and methods have some limitations or inconvenience. Most of these techniques are laborious, time consuming and with chances of false positive or false negative results. It warrants the need of a diagnostic technique which can overcome these limitations and problems. At present, there is emerging trend to use Fluorescence spectroscopy as a diagnostic as well as research tool in many fields of medical sciences. Here, we will critically discuss research studies which propose that Fluorescence spectroscopy may be an excellent diagnostic as well as excellent research tool in medical microbiology field with high sensitivity and specificity.

  4. Delving into cornerstones of hypersensitivity to antineoplastic and biological agents: value of diagnostic tools prior to desensitization.

    PubMed

    Alvarez-Cuesta, E; Madrigal-Burgaleta, R; Angel-Pereira, D; Ureña-Tavera, A; Zamora-Verduga, M; Lopez-Gonzalez, P; Berges-Gimeno, M P

    2015-07-01

    Evidence regarding drug provocation test (DPT) with antineoplastic and biological agents is scarce. Our aim was to assess the usefulness of including DPT as a paramount gold standard diagnostic tool (prior to desensitization). Prospective, observational, longitudinal study with patients who, during a 3-year period, were referred to the Desensitization Program at Ramon y Cajal University Hospital. Patients underwent a structured diagnostic protocol by means of anamnesis, skin tests (ST), risk assessment, and DPT. Oxaliplatin-specific IgE was determined in oxaliplatin-reactive patients (who underwent DPT regardless of oxaliplatin-specific IgE results). Univariate analysis and multivariate analysis were used to identify predictors of the final diagnosis among several variables. A total of 186 patients were assessed. A total of 104 (56%) patients underwent DPT. Sixty-four percent of all DPTs were negative (i.e., hypersensitivity was excluded). Sensitivity for oxaliplatin-specific IgE (0.35 UI/l cutoff point) was 34%, specificity 90.3%, negative predictive value 45.9%, positive predictive value 85%, negative likelihood ratio 0.7, and positive likelihood ratio 3.5. These are the first reported data based on more than 100 DPTs with antineoplastic and biological agents (paclitaxel, oxaliplatin, rituximab, infliximab, irinotecan, and other drugs). Implementation of DPT in diagnostic protocols helps exclude hypersensitivity (in 36% of all referred patients), and avoids unnecessary desensitizations in nonhypersensitive patients (30-56% of patients, depending on culprit-drug). Drug provocation test is vital to validate diagnostic tools; consequently, quality data are shown on oxaliplatin-specific IgE and oxaliplatin-ST in the largest series of oxaliplatin-reactive patients reported to date (74 oxaliplatin-reactive patients). Identifying phenotypes and predictors of a diagnosis of hypersensitivity may be helpful for tailored plans. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Commercial Molecular Tests for Fungal Diagnosis from a Practical Point of View.

    PubMed

    Lackner, Michaela; Lass-Flörl, Cornelia

    2017-01-01

    The increasing interest in molecular diagnostics is a result of tremendously improved knowledge on fungal infections in the past 20 years and the rapid development of new methods, in particular polymerase chain reaction. High expectations have been placed on molecular diagnostics, and the number of laboratories now using the relevant technology is rapidly increasing-resulting in an obvious need for standardization and definition of laboratory organization. In the past 10 years, multiple new molecular tools were marketed for the detection of DNA, antibodies, cell wall components, or other antigens. In contrast to classical culture methods, molecular methods do not detect a viable organisms, but only molecules which indicate its presence; this can be nucleic acids, cell components (antigens), or antibodies (Fig. 1). In this chapter, an overview is provided on commercially available detection tools, their strength and how to use them. A main focus is laid on providing tips and tricks that make daily life easier. We try to focus and mention methodical details which are not highlighted in the manufacturer's instructions of these test kits, but are based on our personal experience in the laboratory. Important to keep in mind is that molecular tools cannot replace culture, microscopy, or a critical view on patients' clinical history, signs, and symptoms, but provide a valuable add on tool. Diagnosis should not be based solely on a molecular test, but molecular tools might deliver an important piece of information that helps matching the diagnostic puzzle to a diagnosis, in particular as few tests are in vitro diagnostic tests (IVD) or only part of the whole test carries the IVD certificate (e.g., DNA extraction is often not included). Please be aware that the authors do not claim to provide a complete overview on all commercially available diagnostic assays being currently marketed for fungal detection, as those are subject to constant change. A main focus is put on commonly used panfungal assays and pathogen-specific assays, including Aspergillus-specific, Candida-specific, Cryptococcus specific, Histoplasma-specific, and Pneumocystis-specific assays. Assays are categorized according to their underlying principle in either antigen-detecting or antibody-detecting or DNA-detecting (Fig. 1). Other non-DNA-detecting nucleic acid methods such as FISH and PNA FISH are not summarized in this chapter and an overview on test performance, common false positives, and the clinical evaluation of commercial tests in studies is provided already in a previous book series by Javier Yugueros Marcos and David H. Pincus (Marcos and Pincus, Methods Mol Biol 968:25-54, 2013).

  6. METABOLOMICS AS A DIAGNOSTIC TOOL FOR SMALL FISH TOXICOLOGY RESEARCH

    EPA Science Inventory

    Metabolomics involves the application of advanced analytical and statistical tools to profile changes in levels of endogenous metabolites in tissues and biofluids resulting from disease onset or stress. While certain metabolites are being specifically targeted in these studies, w...

  7. Utility of quantitative sensory testing and screening tools in identifying HIV-associated peripheral neuropathy in Western Kenya: pilot testing.

    PubMed

    Cettomai, Deanna; Kwasa, Judith; Kendi, Caroline; Birbeck, Gretchen L; Price, Richard W; Bukusi, Elizabeth A; Cohen, Craig R; Meyer, Ana-Claire

    2010-12-08

    Neuropathy is the most common neurologic complication of HIV but is widely under-diagnosed in resource-constrained settings. We aimed to identify tools that accurately distinguish individuals with moderate/severe peripheral neuropathy and can be administered by non-physician healthcare workers (HCW) in resource-constrained settings. We enrolled a convenience sample of 30 HIV-infected outpatients from a Kenyan HIV-care clinic. A HCW administered the Neuropathy Severity Score (NSS), Single Question Neuropathy Screen (Single-QNS), Subjective Peripheral Neuropathy Screen (Subjective-PNS), and Brief Peripheral Neuropathy Screen (Brief-PNS). Monofilament, graduated tuning fork, and two-point discrimination examinations were performed. Tools were validated against a neurologist's clinical assessment of moderate/severe neuropathy. The sample was 57% male, mean age 38.6 years, and mean CD4 count 324 cells/µL. Neurologist's assessment identified 20% (6/30) with moderate/severe neuropathy. Diagnostic utilities for moderate/severe neuropathy were: Single-QNS--83% sensitivity, 71% specificity; Subjective-PNS-total--83% sensitivity, 83% specificity; Subjective-PNS-max and NSS--67% sensitivity, 92% specificity; Brief-PNS--0% sensitivity, 92% specificity; monofilament--100% sensitivity, 88% specificity; graduated tuning fork--83% sensitivity, 88% specificity; two-point discrimination--75% sensitivity, 58% specificity. Pilot testing suggests Single-QNS, Subjective-PNS, and monofilament examination accurately identify HIV-infected patients with moderate/severe neuropathy and may be useful diagnostic tools in resource-constrained settings.

  8. Integrating exhaled breath diagnostics by disease-sniffing dogs with instrumental laboratory analysis

    EPA Science Inventory

    Dogs have been studied for many years as a medical diagnostic tool to detect a pre-clinical disease state by sniffing emissions directly from a human or an in vitro biological sample. Some of the studies report high sensitivity and specificity in blinded case-control studies. How...

  9. [Diagnostic tools for canine parvovirus infection].

    PubMed

    Proksch, A L; Hartmann, K

    2015-01-01

    Canine parvovirus (CPV) infection is one of the most important and common infectious diseases in dogs, in particular affecting young puppies when maternal antibodies have waned and vaccine-induced antibodies have not yet developed. The mortality rate remains high. Therefore, a rapid and safe diagnostic tool is essential to diagnose the disease to 1) provide intensive care treatment and 2) to identify virus-shedding animals and thus prevent virus spread. Whilst the detection of antibodies against CPV is considered unsuitable to diagnose the disease, there are several different methods to directly detect complete virus, virus antigen or DNA. Additionally, to test in commercial laboratories, rapid in-house tests based on ELISA are available worldwide. The specificity of the ELISA rapid in-house tests is reported to be excellent. However, results on sensitivity vary and high numbers of false-negative results are commonly reported, which potentially leads to misdiagnosis. Polymerase chain reaction (PCR) is a very sensitive and specific diagnostic tool. It also provides the opportunity to differentiate vaccine strains from natural infection when sequencing is performed after PCR.

  10. Use of electronic data and existing screening tools to identify clinically significant obstructive sleep apnea.

    PubMed

    Severson, Carl A; Pendharkar, Sachin R; Ronksley, Paul E; Tsai, Willis H

    2015-01-01

    To assess the ability of electronic health data and existing screening tools to identify clinically significant obstructive sleep apnea (OSA), as defined by symptomatic or severe OSA. The present retrospective cohort study of 1041 patients referred for sleep diagnostic testing was undertaken at a tertiary sleep centre in Calgary, Alberta. A diagnosis of clinically significant OSA or an alternative sleep diagnosis was assigned to each patient through blinded independent chart review by two sleep physicians. Predictive variables were identified from online questionnaire data, and diagnostic algorithms were developed. The performance of electronically derived algorithms for identifying patients with clinically significant OSA was determined. Diagnostic performance of these algorithms was compared with versions of the STOP-Bang questionnaire and adjusted neck circumference score (ANC) derived from electronic data. Electronic questionnaire data were highly sensitive (>95%) at identifying clinically significant OSA, but not specific. Sleep diagnostic testing-determined respiratory disturbance index was very specific (specificity ≥95%) for clinically relevant disease, but not sensitive (<35%). Derived algorithms had similar accuracy to the STOP-Bang or ANC, but required fewer questions and calculations. These data suggest that a two-step process using a small number of clinical variables (maximizing sensitivity) and objective diagnostic testing (maximizing specificity) is required to identify clinically significant OSA. When used in an online setting, simple algorithms can identify clinically relevant OSA with similar performance to existing decision rules such as the STOP-Bang or ANC.

  11. A grid matrix-based Raman spectroscopic method to characterize different cell milieu in biopsied axillary sentinel lymph nodes of breast cancer patients.

    PubMed

    Som, Dipasree; Tak, Megha; Setia, Mohit; Patil, Asawari; Sengupta, Amit; Chilakapati, C Murali Krishna; Srivastava, Anurag; Parmar, Vani; Nair, Nita; Sarin, Rajiv; Badwe, R

    2016-01-01

    Raman spectroscopy which is based upon inelastic scattering of photons has a potential to emerge as a noninvasive bedside in vivo or ex vivo molecular diagnostic tool. There is a need to improve the sensitivity and predictability of Raman spectroscopy. We developed a grid matrix-based tissue mapping protocol to acquire cellular-specific spectra that also involved digital microscopy for localizing malignant and lymphocytic cells in sentinel lymph node biopsy sample. Biosignals acquired from specific cellular milieu were subjected to an advanced supervised analytical method, i.e., cross-correlation and peak-to-peak ratio in addition to PCA and PC-LDA. We observed decreased spectral intensity as well as shift in the spectral peaks of amides and lipid bands in the completely metastatic (cancer cells) lymph nodes with high cellular density. Spectral library of normal lymphocytes and metastatic cancer cells created using the cellular specific mapping technique can be utilized to create an automated smart diagnostic tool for bench side screening of sampled lymph nodes. Spectral library of normal lymphocytes and metastatic cancer cells created using the cellular specific mapping technique can be utilized to develop an automated smart diagnostic tool for bench side screening of sampled lymph nodes supported by ongoing global research in developing better technology and signal and big data processing algorithms.

  12. The use of anti-Müllerian hormone as diagnostic for gonadectomy status in dogs.

    PubMed

    Themmen, Axel P N; Kalra, Bhanu; Visser, Jenny A; Kumar, Ajay; Savjani, Gopal; de Gier, Jeffrey; Jaques, Scott

    2016-10-01

    In the veterinary practice, there is a need for a diagnostic tool to check the gonadal status in female dogs because it may be difficult to determine whether a female animal has been spayed or whether there are ovarian remnants. Although less prevalent, a similar situation pertains to male dogs. Anti-Müllerian hormone (AMH) is an important regulator of gonadal function and is a specific gonadal product that can be determined in circulation. The objective of this study was to develop and test a canine blood AMH assay as a diagnostic tool to determine the presence of functional gonadal tissue in dogs. A prospective study with a training-validation set paradigm was used. A canine AMH assay was developed and serum and plasma AMH concentrations were determined in blood samples from 46 intact female dogs, 48 spayed females, 50 intact males, and 48 castrated males collected at two separate institutes. Using a training-validation set paradigm, it was found that using cutoff values of 1.1 ng/mL (female) and 5.5 ng/mL (male) AMH, the assay reported excellent specificity and sensitivity of 100% and 90% in female dogs, and good specificity and sensitivity of 100% and 76%, in male dogs, respectively. The sensitivity in male dogs could be further enhanced by including a serum testosterone determination. This newly developed canine AMH assay is a valuable diagnostic tool to determine gonadal status in veterinary medicine. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Malaria rapid diagnostic tests in elimination settings—can they find the last parasite?

    PubMed Central

    McMorrow, M. L.; Aidoo, M.; Kachur, S. P.

    2016-01-01

    Rapid diagnostic tests (RDTs) for malaria have improved the availability of parasite-based diagnosis throughout the malaria-endemic world. Accurate malaria diagnosis is essential for malaria case management, surveillance, and elimination. RDTs are inexpensive, simple to perform, and provide results in 15–20 min. Despite high sensitivity and specificity for Plasmodium falciparum infections, RDTs have several limitations that may reduce their utility in low-transmission settings: they do not reliably detect low-density parasitaemia (≤200 parasites/μL), many are less sensitive for Plasmodium vivax infections, and their ability to detect Plasmodium ovale and Plasmodium malariae is unknown. Therefore, in elimination settings, alternative tools with higher sensitivity for low-density infections (e.g. nucleic acid-based tests) are required to complement field diagnostics, and new highly sensitive and specific field-appropriate tests must be developed to ensure accurate diagnosis of symptomatic and asymptomatic carriers. As malaria transmission declines, the proportion of low-density infections among symptomatic and asymptomatic persons is likely to increase, which may limit the utility of RDTs. Monitoring malaria in elimination settings will probably depend on the use of more than one diagnostic tool in clinical-care and surveillance activities, and the combination of tools utilized will need to be informed by regular monitoring of test performance through effective quality assurance. PMID:21910780

  14. Molecular Tools for Diagnosis of Visceral Leishmaniasis: Systematic Review and Meta-Analysis of Diagnostic Test Accuracy

    PubMed Central

    de Ruiter, C. M.; van der Veer, C.; Leeflang, M. M. G.; Deborggraeve, S.; Lucas, C.

    2014-01-01

    Molecular methods have been proposed as highly sensitive tools for the detection of Leishmania parasites in visceral leishmaniasis (VL) patients. Here, we evaluate the diagnostic accuracy of these tools in a meta-analysis of the published literature. The selection criteria were original studies that evaluate the sensitivities and specificities of molecular tests for diagnosis of VL, adequate classification of study participants, and the absolute numbers of true positives and negatives derivable from the data presented. Forty studies met the selection criteria, including PCR, real-time PCR, nucleic acid sequence-based amplification (NASBA), and loop-mediated isothermal amplification (LAMP). The sensitivities of the individual studies ranged from 29 to 100%, and the specificities ranged from 25 to 100%. The pooled sensitivity of PCR in whole blood was 93.1% (95% confidence interval [CI], 90.0 to 95.2), and the specificity was 95.6% (95% CI, 87.0 to 98.6). The specificity was significantly lower in consecutive studies, at 63.3% (95% CI, 53.9 to 71.8), due either to true-positive patients not being identified by parasitological methods or to the number of asymptomatic carriers in areas of endemicity. PCR for patients with HIV-VL coinfection showed high diagnostic accuracy in buffy coat and bone marrow, ranging from 93.1 to 96.9%. Molecular tools are highly sensitive assays for Leishmania detection and may contribute as an additional test in the algorithm, together with a clear clinical case definition. We observed wide variety in reference standards and study designs and now recommend consecutively designed studies. PMID:24829226

  15. Diagnostic Machine Learning Models for Acute Abdominal Pain: Towards an e-Learning Tool for Medical Students.

    PubMed

    Khumrin, Piyapong; Ryan, Anna; Judd, Terry; Verspoor, Karin

    2017-01-01

    Computer-aided learning systems (e-learning systems) can help medical students gain more experience with diagnostic reasoning and decision making. Within this context, providing feedback that matches students' needs (i.e. personalised feedback) is both critical and challenging. In this paper, we describe the development of a machine learning model to support medical students' diagnostic decisions. Machine learning models were trained on 208 clinical cases presenting with abdominal pain, to predict five diagnoses. We assessed which of these models are likely to be most effective for use in an e-learning tool that allows students to interact with a virtual patient. The broader goal is to utilise these models to generate personalised feedback based on the specific patient information requested by students and their active diagnostic hypotheses.

  16. Diagnosis and therapy with CRISPR advanced CRISPR based tools for point of care diagnostics and early therapies.

    PubMed

    Uppada, Vanita; Gokara, Mahesh; Rasineni, Girish Kumar

    2018-05-20

    Molecular diagnostics is of critical importance to public health worldwide. It facilitates not only detection and characterization of diseases, but also monitors drug responses, assists in the identification of genetic modifiers and disease susceptibility. Based upon DNA variation, a wide range of molecular-based tests are available to assess/diagnose diseases. The CRISPR-Cas9 system has recently emerged as a versatile tool for biological and medical research. In this system, a single guide RNA (sgRNA) directs the endonuclease Cas9 to a targeted DNA sequence for site-specific manipulation. As designing CRISPR-guided nucleases can be done easily and relatively fast, the CRISPR/Cas9 system has evolved as widely used DNA editing tool. This technique led to a large number of gene editing studies in variety of organisms. CRISPR/Cas9-mediated diagnosis and therapy has picked up pace due to specificity and accuracy of CRISPR. The aim is not only to identify specific pathogens, especially virus but also to repair disease-causing alleles by changing the DNA sequence at the exact location on the chromosome. At present, PCR-based molecular diagnostic testing predominates; however, alternative technologies aimed at reducing genome complexity without PCR are anticipated to gain momentum in the coming years. Furthermore, development of integrated chip devices should allow point-of-care testing and facilitate genetic readouts from single cells and molecules. Together with molecular based therapy CRISPR based diagnostic testing will be a revolution in modern health care settings. In this review, we emphasize on current developing diagnostic techniques based upon CRISPR Cas approach along with short insights on its therapeutic usage. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Diagnosing schistosomiasis: where are we?

    PubMed

    Gomes, Luciana Inácia; Enk, Martin Johannes; Rabello, Ana

    2014-01-01

    In light of the World Health Organization's initiative to extend schistosomiasis morbidity and mortality control programs by including a disease elimination strategy in low endemic settings, this paper reviews diagnostic tools described during the last decades and provide an overview of ongoing efforts in making an efficient diagnostic tool available worldwide. A literature search on PubMed using the search criteria schistosomiasis and diagnosis within the period from 1978 to 2013 was carried out. Articles with abstract in English and that used laboratory techniques specifically developed for the detection of schistosomiasis in humans were included. Publications were categorized according to the methodology applied (parasitological, immunological, or molecular) and stage of development (in house development, limited field, or large scale field testing). The initial research generated 4,535 publications, of which only 643 met the inclusion criteria. The vast majority (537) of the publications focused on immunological techniques; 81 focused on parasitological diagnosis, and 25 focused on molecular diagnostic methods. Regarding the stage of development, 307 papers referred to in-house development, 202 referred to limited field tests, and 134 referred to large scale field testing. The data obtained show that promising new diagnostic tools, especially for Schistosoma antigen and deoxyribonucleic acid (DNA) detection, which are characterized by high sensitivity and specificity, are being developed. In combination with international funding initiatives these tools may result in a significant step forward in successful disease elimination and surveillance, which is to make efficient tests accessible and its large use self-sustainable for control programs in endemic countries.

  18. First results with a lab-on-a-chip system for a fast Phytophthora diagnosis.

    Treesearch

    Sonja Horatzek; Stephan König; Stefan Wagner; Sabine Werres; Lydia Schwenkbier; Karina Weber; Jörg. Weber

    2013-01-01

    For Phytophthora spp. that are quarantine or regulated organisms, highly specific and sensitive diagnostic tools are recommended for surveys and monitoring. Furthermore, these diagnostic techniques should give results within a short time and should be not be too expensive. The techniques currently used for routine diagnosis of ...

  19. DNA barcodes and molecular diagnostics to distinguish an introduced and native Laricobius (Coleoptera: Derodontidae) species in eastern North America

    Treesearch

    G.A. Davis; N.P. Havill; Z.N. Adelman; A. Caccone; L.T. Kok; S.M. Salom

    2011-01-01

    Molecular diagnostics based on DNA barcodes can be powerful identification tools in the absence of distinctive morphological characters for distinguishing between closely related species. A specific example is distinguishing the endemic species Laricobius rubidus from Laricobius nigrinus, a biological control agent of hemlock...

  20. Mass spectrometry based proteomics profiling as diagnostic tool in oncology: current status and future perspective.

    PubMed

    Findeisen, Peter; Neumaier, Michael

    2009-01-01

    Proteomics analysis has been heralded as a novel tool for identifying new and specific biomarkers that may improve diagnosis and monitoring of various disease states. Recent years have brought a number of proteomics profiling technologies. Although proteomics profiling has resulted in the detection of disease-associated differences and modification of proteins, current proteomics technologies display certain limitations that are hampering the introduction of these new technologies into clinical laboratory diagnostics and routine applications. In this review, we summarize current advances in mass spectrometry based biomarker discovery. The promises and challenges of this new technology are discussed with particular emphasis on diagnostic perspectives of mass-spectrometry based proteomics profiling for malignant diseases.

  1. Diagnostic accuracy of repetition tasks for the identification of specific language impairment (SLI) in bilingual children: evidence from Russian and Hebrew.

    PubMed

    Armon-Lotem, Sharon; Meir, Natalia

    2016-11-01

    Previous research demonstrates that repetition tasks are valuable tools for diagnosing specific language impairment (SLI) in monolingual children in English and a variety of other languages, with non-word repetition (NWR) and sentence repetition (SRep) yielding high levels of sensitivity and specificity. Yet, only a few studies have addressed the diagnostic accuracy of repetition tasks in bilingual children, and most available research focuses on English-Spanish sequential bilinguals. To evaluate the efficacy of three repetition tasks (forward digit span (FWD), NWR and SRep) in order to distinguish mono- and bilingual children with and without SLI in Russian and Hebrew. A total of 230 mono- and bilingual children aged 5;5-6;8 participated in the study: 144 bilingual Russian-Hebrew-speaking children (27 with SLI); and 52 monolingual Hebrew-speaking children (14 with SLI) and 34 monolingual Russian-speaking children (14 with SLI). Parallel repetition tasks were designed in both Russian and Hebrew. Bilingual children were tested in both languages. The findings confirmed that NWR and SRep are valuable tools in distinguishing monolingual children with and without SLI in Russian and Hebrew, while the results for FWD were mixed. Yet, testing of bilingual children with the same tools using monolingual cut-off points resulted in inadequate diagnostic accuracy. We demonstrate, however, that the use of bilingual cut-off points yielded acceptable levels of diagnostic accuracy. The combination of SRep tasks in L1/Russian and L2/Hebrew yielded the highest overall accuracy (i.e., 94%), but even SRep alone in L2/Hebrew showed excellent levels of sensitivity (i.e., 100%) and specificity (i.e., 89%), reaching 91% of total diagnostic accuracy. The results are very promising for identifying SLI in bilingual children and for showing that testing in the majority language with bilingual cut-off points can provide an accurate classification. © 2016 Royal College of Speech and Language Therapists.

  2. Xpert MTB/RIF Assay for Pulmonary Tuberculosis and Rifampicin Resistance in Children: a Meta-Analysis.

    PubMed

    Wang, X W; Pappoe, F; Huang, Y; Cheng, X W; Xu, D F; Wang, H; Xu, Y H

    2015-01-01

    The Xpert MTB/RIF assay has been recommended by WHO to replace conventional microscopy, culture, and drug resistance tests. It simultaneously detects both Mycobacterium tuberculosis infection (TB) and resistance to rifampicin (RIF) within two hours. The objective was to review the available research studies on the accuracy of the Xpert MTB/RIF assay for diagnosing pulmonary TB and RIF-resistance in children. A comprehensive search of Pubmed and Embase was performed up to October 28, 2014. We identified published articles estimating the diagnostic accuracy of the Xpert MTB/RIF assay in children with or without HIV using culture or culture plus clinical TB as standard reference. QUADAS-2 tool was used to evaluate the quality of the studies. A summary estimation for sensitivity, specificity, diagnostic odds ratios (DOR), and the area under the summary ROC curve (AUC) was performed. Meta-analysis was used to establish the overall accuracy. 11 diagnostic studies with 3801 patients were included in the systematic review. The overall analysis revealed a moderate sensitivity and high specificity of 65% (95% CI: 61 - 69%) and 99% (95% CI: 98 - 99%), respectively, and a pooled diagnostic odds ratio of 164.09 (95% CI: 111.89 - 240.64). The AUC value was found to be 0.94. The pooled sensitivity and specificity for paediatric rifampicin resistance were 94.0% (95% CI: 80.0 - 93.0%) and 99.0% (95% CI: 95.0 - 98.0%), respectively. Hence, the Xpert MTB/RIF assay has good diagnostic and rifampicin performance for paediatric pulmonary tuberculosis. The Xpert MTB/RIF is sensitive and specific for diagnosing paediatric pulmonary TB. It is also effective in detecting rifamnicin resistance. It can, therefore, be used as an initial diagnostic tool.

  3. Computer-aided dermoscopy for diagnosis of melanoma

    PubMed Central

    Barzegari, Masoomeh; Ghaninezhad, Haiedeh; Mansoori, Parisa; Taheri, Arash; Naraghi, Zahra S; Asgari, Masood

    2005-01-01

    Background Computer-aided dermoscopy using artificial neural networks has been reported to be an accurate tool for the evaluation of pigmented skin lesions. We set out to determine the sensitivity and specificity of a computer-aided dermoscopy system for diagnosis of melanoma in Iranian patients. Methods We studied 122 pigmented skin lesions which were referred for diagnostic evaluation or cosmetic reasons. Each lesion was examined by two clinicians with naked eyes and all of their clinical diagnostic considerations were recorded. The lesions were analyzed using a microDERM® dermoscopy unit. The output value of the software for each lesion was a score between 0 and 10. All of the lesions were excised and examined histologically. Results Histopathological examination revealed melanoma in six lesions. Considering only the most likely clinical diagnosis, sensitivity and specificity of clinical examination for diagnosis of melanoma were 83% and 96%, respectively. Considering all clinical diagnostic considerations, the sensitivity and specificity were 100% and 89%. Choosing a cut-off point of 7.88 for dermoscopy score, the sensitivity and specificity of the score for diagnosis of melanoma were 83% and 96%, respectively. Setting the cut-off point at 7.34, the sensitivity and specificity were 100% and 90%. Conclusion The diagnostic accuracy of the dermoscopy system was at the level of clinical examination by dermatologists with naked eyes. This system may represent a useful tool for screening of melanoma, particularly at centers not experienced in the field of pigmented skin lesions. PMID:16000171

  4. Polymerase chain reaction: A molecular diagnostic tool in periodontology

    PubMed Central

    Maheaswari, Rajendran; Kshirsagar, Jaishree Tukaram; Lavanya, Nallasivam

    2016-01-01

    This review discusses the principles of polymerase chain reaction (PCR) and its application as a diagnostic tool in periodontology. The relevant MEDLINE and PubMed indexed journals were searched manually and electronically by typing PCR, applications of PCR, PCR in periodontics, polymorphism studies in periodontitis, and molecular techniques in periodontology. The searches were limited to articles in English language and the articles describing PCR process and its relation to periodontology were collected and used to prepare a concise review. PCR has now become a standard diagnostic and research tool in periodontology. Various studies reveal that its sensitivity and specificity allow it as a rapid, efficient method of detecting, identifying, and quantifying organism. Different immune and inflammatory markers can be identified at the mRNA expression level, and also the determination of genetic polymorphisms, thus providing the deeper insight into the mechanisms underlying the periodontal disease. PMID:27143822

  5. Developing a Multi-Dimensional Early Elementary Mathematics Screener and Diagnostic Tool: The Primary Mathematics Assessment.

    PubMed

    Brendefur, Jonathan L; Johnson, Evelyn S; Thiede, Keith W; Strother, Sam; Severson, Herb H

    2018-01-01

    There is a critical need to identify primary level students experiencing difficulties in mathematics to provide immediate and targeted instruction that remediates their deficits. However, most early math screening instruments focus only on the concept of number, resulting in inadequate and incomplete information for teachers to design intervention efforts. We propose a mathematics assessment that screens and provides diagnostic information in six domains that are important to building a strong foundation in mathematics. This article describes the conceptual framework and psychometric qualities of a web-based assessment tool, the Primary Math Assessment (PMA). The PMA includes a screener to identify students at risk for poor math outcomes and a diagnostic tool to provide a more in-depth profile of children's specific strengths and weaknesses in mathematics. The PMA allows teachers and school personnel to make better instructional decisions by providing more targeted analyses.

  6. Podocytes from the diagnostic and therapeutic point of view.

    PubMed

    Müller-Deile, Janina; Schiffer, Mario

    2017-08-01

    The central role of podocytes in glomerular diseases makes this cell type an interesting diagnostic tool as well as a therapeutic target. In this review, we discuss the current literature on the use of podocytes and podocyte-specific markers as non-invasive diagnostic tools in different glomerulopathies. Furthermore, we highlight the direct effects of drugs currently used to treat primary glomerular diseases and describe their direct cellular effects on podocytes. A new therapeutic potential is seen in drugs targeting the podocytic actin cytoskeleton which is essential for podocyte foot process structure and function. Incubation of cultured human podocyte cell lines with sera from patients with active glomerular diseases is currently also used to identify novel circulating factors with pathophysiological relevance for the glomerular filtration barrier. In addition, treatment of detached urinary podocytes from patients with substances that restore their cytoskeleton might serve as a novel personalized tool to estimate their potential for podocyte recovery ex vivo.

  7. Polymerase chain reaction: A molecular diagnostic tool in periodontology.

    PubMed

    Maheaswari, Rajendran; Kshirsagar, Jaishree Tukaram; Lavanya, Nallasivam

    2016-01-01

    This review discusses the principles of polymerase chain reaction (PCR) and its application as a diagnostic tool in periodontology. The relevant MEDLINE and PubMed indexed journals were searched manually and electronically by typing PCR, applications of PCR, PCR in periodontics, polymorphism studies in periodontitis, and molecular techniques in periodontology. The searches were limited to articles in English language and the articles describing PCR process and its relation to periodontology were collected and used to prepare a concise review. PCR has now become a standard diagnostic and research tool in periodontology. Various studies reveal that its sensitivity and specificity allow it as a rapid, efficient method of detecting, identifying, and quantifying organism. Different immune and inflammatory markers can be identified at the mRNA expression level, and also the determination of genetic polymorphisms, thus providing the deeper insight into the mechanisms underlying the periodontal disease.

  8. Molecular tools for diagnosis of visceral leishmaniasis: systematic review and meta-analysis of diagnostic test accuracy.

    PubMed

    de Ruiter, C M; van der Veer, C; Leeflang, M M G; Deborggraeve, S; Lucas, C; Adams, E R

    2014-09-01

    Molecular methods have been proposed as highly sensitive tools for the detection of Leishmania parasites in visceral leishmaniasis (VL) patients. Here, we evaluate the diagnostic accuracy of these tools in a meta-analysis of the published literature. The selection criteria were original studies that evaluate the sensitivities and specificities of molecular tests for diagnosis of VL, adequate classification of study participants, and the absolute numbers of true positives and negatives derivable from the data presented. Forty studies met the selection criteria, including PCR, real-time PCR, nucleic acid sequence-based amplification (NASBA), and loop-mediated isothermal amplification (LAMP). The sensitivities of the individual studies ranged from 29 to 100%, and the specificities ranged from 25 to 100%. The pooled sensitivity of PCR in whole blood was 93.1% (95% confidence interval [CI], 90.0 to 95.2), and the specificity was 95.6% (95% CI, 87.0 to 98.6). The specificity was significantly lower in consecutive studies, at 63.3% (95% CI, 53.9 to 71.8), due either to true-positive patients not being identified by parasitological methods or to the number of asymptomatic carriers in areas of endemicity. PCR for patients with HIV-VL coinfection showed high diagnostic accuracy in buffy coat and bone marrow, ranging from 93.1 to 96.9%. Molecular tools are highly sensitive assays for Leishmania detection and may contribute as an additional test in the algorithm, together with a clear clinical case definition. We observed wide variety in reference standards and study designs and now recommend consecutively designed studies. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  9. Molecular phylogenetic analysis of Enterobius vermicularis and development of an 18S ribosomal DNA-targeted diagnostic PCR.

    PubMed

    Zelck, Ulrike E; Bialek, Ralf; Weiss, Michael

    2011-04-01

    We genetically characterized pinworms obtained from 37 children from different regions of Germany and established new species-specific molecular diagnostic tools. No ribosomal DNA diversity was found; the phylogenetic position of Enterobius vermicularis within the Oxyurida order and its close relationship to the Ascaridida and Spirurida orders was confirmed.

  10. Reflectometric measurement of plasma imaging and applications

    NASA Astrophysics Data System (ADS)

    Mase, A.; Ito, N.; Oda, M.; Komada, Y.; Nagae, D.; Zhang, D.; Kogi, Y.; Tobimatsu, S.; Maruyama, T.; Shimazu, H.; Sakata, E.; Sakai, F.; Kuwahara, D.; Yoshinaga, T.; Tokuzawa, T.; Nagayama, Y.; Kawahata, K.; Yamaguchi, S.; Tsuji-Iio, S.; Domier, C. W.; Luhmann, N. C., Jr.; Park, H. K.; Yun, G.; Lee, W.; Padhi, S.; Kim, K. W.

    2012-01-01

    Progress in microwave and millimeter-wave technologies has made possible advanced diagnostics for application to various fields, such as, plasma diagnostics, radio astronomy, alien substance detection, airborne and spaceborne imaging radars called as synthetic aperture radars, living body measurements. Transmission, reflection, scattering, and radiation processes of electromagnetic waves are utilized as diagnostic tools. In this report we focus on the reflectometric measurements and applications to biological signals (vital signal detection and breast cancer detection) as well as plasma diagnostics, specifically by use of imaging technique and ultra-wideband radar technique.

  11. Mast cell activation test in the diagnosis of allergic disease and anaphylaxis.

    PubMed

    Bahri, Rajia; Custovic, Adnan; Korosec, Peter; Tsoumani, Marina; Barron, Martin; Wu, Jiakai; Sayers, Rebekah; Weimann, Alf; Ruiz-Garcia, Monica; Patel, Nandinee; Robb, Abigail; Shamji, Mohamed H; Fontanella, Sara; Silar, Mira; Mills, E N Clare; Simpson, Angela; Turner, Paul J; Bulfone-Paus, Silvia

    2018-03-05

    Food allergy is an increasing public health issue and the most common cause of life-threatening anaphylactic reactions. Conventional allergy tests assess for the presence of allergen-specific IgE, significantly overestimating the rate of true clinical allergy and resulting in overdiagnosis and adverse effect on health-related quality of life. To undertake initial validation and assessment of a novel diagnostic tool, we used the mast cell activation test (MAT). Primary human blood-derived mast cells (MCs) were generated from peripheral blood precursors, sensitized with patients' sera, and then incubated with allergen. MC degranulation was assessed by means of flow cytometry and mediator release. We compared the diagnostic performance of MATs with that of existing diagnostic tools to assess in a cohort of peanut-sensitized subjects undergoing double-blind, placebo-controlled challenge. Human blood-derived MCs sensitized with sera from patients with peanut, grass pollen, and Hymenoptera (wasp venom) allergy demonstrated allergen-specific and dose-dependent degranulation, as determined based on both expression of surface activation markers (CD63 and CD107a) and functional assays (prostaglandin D 2 and β-hexosaminidase release). In this cohort of peanut-sensitized subjects, the MAT was found to have superior discrimination performance compared with other testing modalities, including component-resolved diagnostics and basophil activation tests. Using functional principle component analysis, we identified 5 clusters or patterns of reactivity in the resulting dose-response curves, which at preliminary analysis corresponded to the reaction phenotypes seen at challenge. The MAT is a robust tool that can confer superior diagnostic performance compared with existing allergy diagnostics and might be useful to explore differences in effector cell function between basophils and MCs during allergic reactions. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  12. Accuracy of Urine Color to Detect Equal to or Greater Than 2% Body Mass Loss in Men.

    PubMed

    McKenzie, Amy L; Muñoz, Colleen X; Armstrong, Lawrence E

    2015-12-01

    Clinicians and athletes can benefit from field-expedient measurement tools, such as urine color, to assess hydration state; however, the diagnostic efficacy of this tool has not been established. To determine the diagnostic accuracy of urine color assessment to distinguish a hypohydrated state (≥2% body mass loss [BML]) from a euhydrated state (<2% BML) after exercise in a hot environment. Controlled laboratory study. Environmental chamber in a laboratory. Twenty-two healthy men (age = 22 ± 3 years, height = 180.4 ± 8.7 cm, mass = 77.9 ± 12.8 kg, body fat = 10.6% ± 4.6%). Participants cycled at 68% ± 6% of their maximal heart rates in a hot environment (36°C ± 1°C) for 5 hours or until 5% BML was achieved. At the point of each 1% BML, we assessed urine color. Diagnostic efficacy of urine color was assessed using receiver operating characteristic curve analysis, sensitivity, specificity, and likelihood ratios. Urine color was useful as a diagnostic tool to identify hypohydration after exercise in the heat (area under the curve = 0.951, standard error = 0.022; P < .001). A urine color of 5 or greater identified BML ≥2% with 88.9% sensitivity and 84.8% specificity (positive likelihood ratio = 5.87, negative likelihood ratio = 0.13). Under the conditions of acute dehydration due to exercise in a hot environment, urine color assessment can be a valid, practical, inexpensive tool for assessing hydration status. Researchers should examine the utility of urine color to identify a hypohydrated state under different BML conditions.

  13. Nasal potential difference measurements in diagnosis of cystic fibrosis: an international survey.

    PubMed

    Naehrlich, Lutz; Ballmann, Manfred; Davies, Jane; Derichs, Nico; Gonska, Tanja; Hjelte, Lena; van Konigsbruggen-Rietschel, Silke; Leal, Teresinha; Melotti, Paola; Middleton, Peter; Tümmler, Burkhard; Vermeulen, Francois; Wilschanski, Michael

    2014-01-01

    The role of nasal potential difference (NPD) measurement as a diagnostic test for cystic fibrosis (CF) is a subject of global controversy because of the lack of validation studies, clear reference values, and standardized protocols for diagnostic NPD. To determine diagnostic NPD frequency, protocols, interpretation, and rater agreement, we surveyed the 18 NPD centres of the European Cystic Fibrosis Society Diagnostic Network Working Group. Fifteen centres reported performing 373 diagnostic NPDs in 2012. Most use the CFF-TDN-SOP (67%) and the chloride-free + isoproterenol response of the side with the largest response (47%) as diagnostic criteria and use centre-specific reference ranges. Rater agreement for five NPD tracings - in general - was good, but poor in tracings with different responses between the two nostrils. NPD is frequently used as a diagnostic and research tool for CF. Performance is highly standardized, centre-specific reference ranges are established, and rater agreement - in general - is good. Centre-independent diagnostic criteria and reference ranges must be defined by multicentre validation studies to improve standardized interpretation for diagnostic use. © 2013.

  14. Automated classification of focal breast lesions according to S-detect: validation and role as a clinical and teaching tool.

    PubMed

    Di Segni, Mattia; de Soccio, Valeria; Cantisani, Vito; Bonito, Giacomo; Rubini, Antonello; Di Segni, Gabriele; Lamorte, Sveva; Magri, Valentina; De Vito, Corrado; Migliara, Giuseppe; Bartolotta, Tommaso Vincenzo; Metere, Alessio; Giacomelli, Laura; de Felice, Carlo; D'Ambrosio, Ferdinando

    2018-06-01

    To assess the diagnostic performance and the potential as a teaching tool of S-detect in the assessment of focal breast lesions. 61 patients (age 21-84 years) with benign breast lesions in follow-up or candidate to pathological sampling or with suspicious lesions candidate to biopsy were enrolled. The study was based on a prospective and on a retrospective phase. In the prospective phase, after completion of baseline US by an experienced breast radiologist and S-detect assessment, 5 operators with different experience and dedication to breast radiology performed elastographic exams. In the retrospective phase, the 5 operators performed a retrospective assessment and categorized lesions with BI-RADS 2013 lexicon. Integration of S-detect to in-training operators evaluations was performed by giving priority to S-detect analysis in case of disagreement. 2 × 2 contingency tables and ROC analysis were used to assess the diagnostic performances; inter-rater agreement was measured with Cohen's k; Bonferroni's test was used to compare performances. A significance threshold of p = 0.05 was adopted. All operators showed sensitivity > 90% and varying specificity (50-75%); S-detect showed sensitivity > 90 and 70.8% specificity, with inter-rater agreement ranging from moderate to good. Lower specificities were improved by the addition of S-detect. The addition of elastography did not lead to any improvement of the diagnostic performance. S-detect is a feasible tool for the characterization of breast lesions; it has a potential as a teaching tool for the less experienced operators.

  15. Clinical Validity of the ADI-R in a US-Based Latino Population.

    PubMed

    Vanegas, Sandra B; Magaña, Sandra; Morales, Miguel; McNamara, Ellyn

    2016-05-01

    The Autism Diagnostic Interview-Revised (ADI-R) has been validated as a tool to aid in the diagnosis of Autism; however, given the growing diversity in the United States, the ADI-R must be validated for different languages and cultures. This study evaluates the validity of the ADI-R in a US-based Latino, Spanish-speaking population of 50 children and adolescents with ASD and developmental disability. Sensitivity and specificity of the ADI-R as a diagnostic tool were moderate, but lower than previously reported values. Validity of the social reciprocity and restrictive and repetitive behaviors domains was high, but low in the communication domain. Findings suggest that language discordance between caregiver and child may influence reporting of communication symptoms and contribute to lower sensitivity and specificity.

  16. Advancements in nano-enabled therapeutics for neuroHIV management.

    PubMed

    Kaushik, Ajeet; Jayant, Rahul Dev; Nair, Madhavan

    This viewpoint is a global call to promote fundamental and applied research aiming toward designing smart nanocarriers of desired properties, novel noninvasive strategies to open the blood-brain barrier (BBB), delivery/release of single/multiple therapeutic agents across the BBB to eradicate neurohuman immunodeficiency virus (HIV), strategies for on-demand site-specific release of antiretroviral therapy, developing novel nanoformulations capable to recognize and eradicate latently infected HIV reservoirs, and developing novel smart analytical diagnostic tools to detect and monitor HIV infection. Thus, investigation of novel nanoformulations, methodologies for site-specific delivery/release, analytical methods, and diagnostic tools would be of high significance to eradicate and monitor neuroacquired immunodeficiency syndrome. Overall, these developments will certainly help to develop personalized nanomedicines to cure HIV and to develop smart HIV-monitoring analytical systems for disease management.

  17. Detecting anxiety in individuals with Parkinson disease: A systematic review.

    PubMed

    Mele, Bria; Holroyd-Leduc, Jayna; Smith, Eric E; Pringsheim, Tamara; Ismail, Zahinoor; Goodarzi, Zahra

    2018-01-02

    To examine diagnostic accuracy of anxiety detection tools compared with a gold standard in outpatient settings among adults with Parkinson disease (PD). A systematic review was conducted. MEDLINE, EMABASE, PsycINFO, and Cochrane Database of Systematic Reviews were searched to April 7, 2017. Prevalence of anxiety and diagnostic accuracy measures including sensitivity, specificity, and likelihood ratios were gathered. Pooled prevalence of anxiety was calculated using Mantel-Haenszel-weighted DerSimonian and Laird models. A total of 6,300 citations were reviewed with 6 full-text articles included for synthesis. Tools included within this study were the Beck Anxiety Inventory, Geriatric Anxiety Inventory (GAI), Hamilton Anxiety Rating Scale, Hospital Anxiety and Depression Scale-Anxiety, Parkinson's Anxiety Scale (PAS), and Mini-Social Phobia Inventory. Anxiety diagnoses made included generalized anxiety disorder, social phobia, and any anxiety type. Pooled prevalence of anxiety was 30.1% (95% confidence interval 26.1%-34.0%). The GAI had the best-reported sensitivity of 0.86 and specificity of 0.88. The observer-rated PAS had a sensitivity of 0.71 and the highest specificity of 0.91. While there are 6 tools validated for anxiety screening in PD populations, most tools are only validated in single studies. The GAI is brief and easy to use, with a good balance of sensitivity and specificity. The PAS was specifically developed for PD, is brief, and has self-/observer-rated scales, but with lower sensitivity. Health care practitioners involved in PD care need to be aware of available validated tools and choose one that fits their practice. Copyright © 2017 American Academy of Neurology.

  18. A Comparison of Optical, Electrochemical, Magnetic, and Colorimetric Point-of-Care Biosensors for Infectious Disease Diagnosis.

    PubMed

    Pashchenko, Oleksandra; Shelby, Tyler; Banerjee, Tuhina; Santra, Santimukul

    2018-06-18

    Each year, infectious diseases are responsible for millions of deaths, most of which occur in the rural areas of developing countries. Many of the infectious disease diagnostic tools used today require a great deal of time, a laboratory setting, and trained personnel. Due to this, the need for effective point-of-care (POC) diagnostic tools is greatly increasing with an emphasis on affordability, portability, sensitivity, specificity, timeliness, and ease of use. In this Review, we discuss the various diagnostic modalities that have been utilized toward this end and are being further developed to create POC diagnostic technologies, and we focus on potential effectiveness in resource-limited settings. The main modalities discussed herein are optical-, electrochemical-, magnetic-, and colorimetric-based modalities utilized in diagnostic technologies for infectious diseases. Each of these modalities feature pros and cons when considering application in POC settings but, overall, reveal a promising outlook for the future of this field of technological development.

  19. Molecular Phylogenetic Analysis of Enterobius vermicularis and Development of an 18S Ribosomal DNA-Targeted Diagnostic PCR▿

    PubMed Central

    Zelck, Ulrike E.; Bialek, Ralf; Weiß, Michael

    2011-01-01

    We genetically characterized pinworms obtained from 37 children from different regions of Germany and established new species-specific molecular diagnostic tools. No ribosomal DNA diversity was found; the phylogenetic position of Enterobius vermicularis within the Oxyurida order and its close relationship to the Ascaridida and Spirurida orders was confirmed. PMID:21248085

  20. Development of Molecular Methods to Detect Macrophomina phaseolina from Strawberry Plants and Soil.

    PubMed

    Burkhardt, Alyssa; Ramon, Marina L; Smith, Brett; Koike, Steven T; Martin, Frank N

    2018-06-05

    Macrophomina phaseolina is a broad-host range fungus that shows some degree of host preference on strawberry, and causes symptoms including crown rot and root rot. Recently, this pathogen has impacted strawberry production as fumigation practices have changed, leaving many growers in California and around the world in need of accurate, rapid diagnostic tools for M. phaseolina in soil and infected plants. This study uses next-generation sequencing and comparative genomics to identify a locus that is unique to isolates within a main genotype shared by a majority of isolates that infect strawberry. This locus was used to develop a quantitative single-tube nested TaqMan qPCR assay which is able to quantify as little as 2-3 microsclerotia/g of soil with 100% genotype specificity. An isothermal assay using recombinase polymerase amplification (RPA) was developed from the same locus and has been validated on over 200 infected strawberry plants with a diagnostic sensitivity of 93% and a diagnostic specificity of 99%, respectively. Together, this work demonstrates the value of using new approaches to identify loci for detection and provides valuable diagnostic tools that can be used to monitor soil and strawberry plant samples for M. phaseolina.

  1. Nanotechnology-Based Surface Plasmon Resonance Affinity Biosensors for In Vitro Diagnostics

    PubMed Central

    Antiochia, Riccarda; Bollella, Paolo; Favero, Gabriele

    2016-01-01

    In the last decades, in vitro diagnostic devices (IVDDs) became a very important tool in medicine for an early and correct diagnosis, a proper screening of targeted population, and also assessing the efficiency of a specific therapy. In this review, the most recent developments regarding different configurations of surface plasmon resonance affinity biosensors modified by using several nanostructured materials for in vitro diagnostics are critically discussed. Both assembly and performances of the IVDDs tested in biological samples are reported and compared. PMID:27594884

  2. Raman spectroscopy and PCA-SVM as a non-invasive diagnostic tool to identify and classify qualitatively glycated hemoglobin levels in vivo.

    PubMed

    Villa-Manríquez, J F; Castro-Ramos, J; Gutiérrez-Delgado, F; Lopéz-Pacheco, M A; Villanueva-Luna, A E

    2017-08-01

    In this study we identify and classify high and low levels of glycated hemoglobin (HbA1c) in healthy volunteers (HV) and diabetic patients (DP). Overall, 86 subjects were evaluated. The Raman spectrum was measured in three anatomical regions of the body: index fingertip, right ear lobe, and forehead. The measurements were performed to compare the difference between the HV and DP (22 well controlled diabetic patients (WCDP) (HbA1c <6.5%), and 49 not controlled diabetic patients (NCDP) (HbA1c ≥6.5%)). Multivariable methods such as principal components analysis (PCA) combined with support vector machine (SVM) were used to develop effective diagnostic algorithms for classification among these groups. The forehead of HV versus WCDP showed the highest sensitivity (100%) and specificity (100%). Sensitivity (100%) and specificity (60%), were highest in the forehead of WCDP, versus NCDP. In HV versus NCDP, the fingertip had the highest sensitivity (100%) and specificity (80%). The efficacy of the diagnostic algorithm by receiver operating characteristic (ROC) curve was confirmed. Overall, our study demonstrated that the combination of Raman spectroscopy and PCA-SVM are feasible non-invasive diagnostic tool in diabetes to classify qualitatively high and low levels of HbA1c in vivo. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Depression Case Finding in Individuals with Dementia: A Systematic Review and Meta-Analysis.

    PubMed

    Goodarzi, Zahra S; Mele, Bria S; Roberts, Derek J; Holroyd-Leduc, Jayna

    2017-05-01

    To compare the diagnostic accuracy of depression case finding tools with a criterion standard in the outpatient setting among adults with dementia. Systematic review and meta-analysis. Studies of older outpatients with dementia. Elderly outpatients (clinic and long-term care) with dementia (N = 3,035). Prevalence of major depression and diagnostic accuracy measures including sensitivity, specificity, and likelihood ratios. From the 11,539 citations, 20 studies were included for qualitative synthesis and 15 for a meta-analysis. Tools included were the Montgomery Åsberg Depression Rating Scale, Cornell Scale for Depression in Dementia (CSDD), Geriatric Depression Scale (GDS), Center for Epidemiologic Studies Depression Scale (CES-D), Hamilton Depression Rating Scale (HDRS), Single Question, Nijmegen Observer-Rated Depression Scale, and Even Briefer Assessment Scale-Depression. The pooled prevalence of depression in individuals with dementia was 30.3% (95% CI = 22.1-38.5). The average age was 75.2 (95% CI = 71.7-78.7), and mean Mini-Mental State Examination scores ranged from 11.2 to 24. The diagnostic accuracy of the individual tools was pooled for the best-reported cutoffs and for each cutoff, if available. The CSDD had a sensitivity of 0.84 (95% CI = 0.73-0.91) and a specificity of 0.80 (95% CI = 0.65-0.90), the 30-item GDS (GDS-30) had a sensitivity of 0.62 (95% CI = 0.45-0.76) and a specificity 0.81 (95% CI = 0.75-0.85), and the HDRS had a sensitivity of 0.86 (95% CI = 0.63-0.96) and a specificity of 0.84 (95% CI = 0.76-0.90). Summary statistics for all tools across best-reported cutoffs had significant heterogeneity. There are many validated tools for the detection of depression in individuals with dementia. Tools that incorporate a physician interview with patient and collateral histories, the CSDD and HDRS, have higher sensitivities, which would ensure fewer false-negatives. © 2017, Copyright the Authors Journal compilation © 2017, The American Geriatrics Society.

  4. 3 Tesla breast MR imaging as a problem-solving tool: Diagnostic performance and incidental lesions

    PubMed Central

    Spick, Claudio; Szolar, Dieter H. M.; Preidler, Klaus W.; Reittner, Pia; Rauch, Katharina; Brader, Peter; Tillich, Manfred

    2018-01-01

    Purpose To investigate the diagnostic performance and incidental lesion yield of 3T breast MRI if used as a problem-solving tool. Methods This retrospective, IRB-approved, cross-sectional, single-center study comprised 302 consecutive women (mean: 50±12 years; range: 20–79 years) who were undergoing 3T breast MRI between 03/2013-12/2014 for further workup of conventional and clinical breast findings. Images were read by experienced, board-certified radiologists. The reference standard was histopathology or follow-up ≥ two years. Sensitivity, specificity, PPV, and NPV were calculated. Results were stratified by conventional and clinical breast findings. Results The reference standard revealed 53 true-positive, 243 true-negative, 20 false-positive, and two false-negative breast MRI findings, resulting in a sensitivity, specificity, PPV, and NPV of 96.4% (53/55), 92.4% (243/263), 72.6% (53/73), and 99.2% (243/245), respectively. In 5.3% (16/302) of all patients, incidental MRI lesions classified BI-RADS 3–5 were detected, 37.5% (6/16) of which were malignant. Breast composition and the imaging findings that had led to referral had no significant influence on the diagnostic performance of breast MR imaging (p>0.05). Conclusion 3T breast MRI yields excellent diagnostic results if used as a problem-solving tool independent of referral reasons. The number of suspicious incidental lesions detected by MRI is low, but is associated with a substantial malignancy rate. PMID:29293582

  5. Portable Diagnostics Technology Assessment for Space Missions. Part 1; General Technology Capabilities for NASA Exploration Missions

    NASA Technical Reports Server (NTRS)

    Nelson, Emily S.; Chait, Arnon

    2010-01-01

    The changes in the scope of NASA s mission in the coming decade are profound and demand nimble, yet insightful, responses. On-board clinical and environmental diagnostics must be available for both mid-term lunar and long-term Mars exploration missions in an environment marked by scarce resources. Miniaturization has become an obvious focus. Despite solid achievements in lab-based devices, broad-based, robust tools for application in the field are not yet on the market. The confluence of rapid, wide-ranging technology evolution and internal planning needs are the impetus behind this work. This report presents an analytical tool for the ongoing evaluation of promising technology platforms based on mission- and application-specific attributes. It is not meant to assess specific devices, but rather to provide objective guidelines for a rational down-select of general categories of technology platforms. In this study, we have employed our expertise in the microgravity operation of fluidic devices, laboratory diagnostics for space applications, and terrestrial research in biochip development. A rating of the current state of technology development is presented using the present tool. Two mission scenarios are also investigated: a 30-day lunar mission using proven, tested technology in 5 years; and a 2- to 3-year mission to Mars in 10 to 15 years.

  6. A Constitutive Relationship between Crack Propagation and Specific Damping Capacity in Steel

    DTIC Science & Technology

    1990-10-01

    diagnostic tool for detecting crack growth in structures. The model must be simple to act as a tool, but it must be comprehensive to provide accuracy...strain for static fracture u ECritical strain above which plastic strain occursP EAverage value of the cyclic plastic-strain rangeP E t ln(Ao/AI), true

  7. Diagnostic performance of an indirect enzyme-linked immunosorbent assay (ELISA) to detect bovine leukemia virus antibodies in bulk-tank milk samples.

    PubMed

    Nekouei, Omid; Durocher, Jean; Keefe, Greg

    2016-07-01

    This study assessed the diagnostic performance of a commercial ELISA for detecting bovine leukemia virus antibodies in bulk-tank milk samples from eastern Canada. Sensitivity and specificity of the test were estimated at 97.2% and 100%, respectively. The test was recommended as a cost-efficient tool for large-scale screening programs.

  8. Diagnostic performance of an indirect enzyme-linked immunosorbent assay (ELISA) to detect bovine leukemia virus antibodies in bulk-tank milk samples

    PubMed Central

    Nekouei, Omid; Durocher, Jean; Keefe, Greg

    2016-01-01

    This study assessed the diagnostic performance of a commercial ELISA for detecting bovine leukemia virus antibodies in bulk-tank milk samples from eastern Canada. Sensitivity and specificity of the test were estimated at 97.2% and 100%, respectively. The test was recommended as a cost-efficient tool for large-scale screening programs. PMID:27429469

  9. Diagnostic Accuracy of Fall Risk Assessment Tools in People With Diabetic Peripheral Neuropathy

    PubMed Central

    Pohl, Patricia S.; Mahnken, Jonathan D.; Kluding, Patricia M.

    2012-01-01

    Background Diabetic peripheral neuropathy affects nearly half of individuals with diabetes and leads to increased fall risk. Evidence addressing fall risk assessment for these individuals is lacking. Objective The purpose of this study was to identify which of 4 functional mobility fall risk assessment tools best discriminates, in people with diabetic peripheral neuropathy, between recurrent “fallers” and those who are not recurrent fallers. Design A cross-sectional study was conducted. Setting The study was conducted in a medical research university setting. Participants The participants were a convenience sample of 36 individuals between 40 and 65 years of age with diabetic peripheral neuropathy. Measurements Fall history was assessed retrospectively and was the criterion standard. Fall risk was assessed using the Functional Reach Test, the Timed “Up & Go” Test, the Berg Balance Scale, and the Dynamic Gait Index. Sensitivity, specificity, positive and negative likelihood ratios, and overall diagnostic accuracy were calculated for each fall risk assessment tool. Receiver operating characteristic curves were used to estimate modified cutoff scores for each fall risk assessment tool; indexes then were recalculated. Results Ten of the 36 participants were classified as recurrent fallers. When traditional cutoff scores were used, the Dynamic Gait Index and Functional Reach Test demonstrated the highest sensitivity at only 30%; the Dynamic Gait Index also demonstrated the highest overall diagnostic accuracy. When modified cutoff scores were used, all tools demonstrated improved sensitivity (80% or 90%). Overall diagnostic accuracy improved for all tests except the Functional Reach Test; the Timed “Up & Go” Test demonstrated the highest diagnostic accuracy at 88.9%. Limitations The small sample size and retrospective fall history assessment were limitations of the study. Conclusions Modified cutoff scores improved diagnostic accuracy for 3 of 4 fall risk assessment tools when testing people with diabetic peripheral neuropathy. PMID:22836004

  10. Research Areas: Diagnosis

    Cancer.gov

    Accurate information derived from diagnostic tools is critical for making decisions at all stages of cancer care. NCI supports research on the development of tests and imaging technologies that can provide specific information about an individual’s cancer.

  11. Development and clinical evaluation of a rapid diagnostic kit for feline leukemia virus infection.

    PubMed

    Kim, Won-Shik; Chong, Chom-Kyu; Kim, Hak-Yong; Lee, Gyu-Cheol; Jeong, Wooseog; An, Dong-Jun; Jeoung, Hye-Young; Lee, Jae-In; Lee, Young-Ki

    2014-01-01

    Feline leukemia virus (FeLV) causes a range of neoplastic and degenerative diseases in cats. To obtain a more sensitive and convenient diagnosis of the disease, we prepared monoclonal antibodies specific for the FeLV p27 to develop a rapid diagnostic test with enhanced sensitivity and specificity. Among these antibodies, we identified two clones (hybridomas 8F8B5 and 8G7D1) that specifically bound to FeLV and were very suitable for a diagnostic kit. The affinity constants for 8F8B5 and 8G7D1 were 0.35 × 10⁸ and 0.86 × 10⁸, respectively. To investigate the diagnostic abilities of the rapid kit using these antibodies, we performed several clinical studies. Assessment of analytical sensitivity revealed that the detection threshold of the rapid diagnostic test was 2 ng/mL for recombinant p27 and 12.5 × 10⁴ IU/mL for FeLV. When evaluating 252 cat sera samples, the kit was found to have a kappa value of 0.88 compared to polymerase chain reaction (PCR), indicating a significant correlation between data from the rapid diagnostic test and PCR. Sensitivity and specificity of the kit were 95.2% (20/21) and 98.5% (257/261), respectively. Our results demonstrated that the rapid diagnostic test would be a suitable diagnostic tool for the rapid detection of FeLV infection in cats.

  12. Gastrointestinal Diagnosis of Classical Whipple Disease: Clinical, Endoscopic, and Histopathologic Features in 191 Patients

    PubMed Central

    Günther, Ute; Moos, Verena; Offenmüller, Gabriel; Oelkers, Gerrit; Heise, Walther; Moter, Annette; Loddenkemper, Christoph; Schneider, Thomas

    2015-01-01

    Abstract Classic Whipple disease (CWD) is a systemic infection caused by Tropheryma whipplei. Different diagnostic tools have been developed over the last decades: periodic acid-Schiff (PAS) staining, T whipplei-specific polymerase chain reaction (PCR), and T whipplei-specific immunohistochemistry (IHC). Despite all these advances, CWD is still difficult to diagnose because of a variety of clinical symptoms and possibly a long time span between first unspecific symptoms and the full-blown clinical picture of the disease. Herein, we report an observational cohort study summarizing epidemiologic data, clinical manifestations, and diagnostic parameters of 191 patients with CWD collected at our institution. Gastrointestinal manifestations are the most characteristic symptoms of CWD affecting 76% of the cohort. Although the small bowel was macroscopically conspicuous in only 27% of cases, 173 (91%) patients presented with characteristic histological changes in small bowel biopsies (in 2 patients, these changes were only seen within the ileum). However, 18 patients displayed normal small bowel histology without typical PAS staining. In 9 of these patients, alternative test were positive from their duodenal specimens (ie, T whipplei-specific PCR and/or IHC). Thus, in 182 patients (95%) a diagnostic hint toward CWD was obtained from small bowel biopsies. Only 9 patients (5%) were diagnosed solely based on positive T whipplei-specific PCR and/or IHC of extraintestinal fluids (eg, cerebrospinal fluid, synovial fluid) or extraintestinal tissue (eg, lymph node, synovial tissue), respectively. Thus, despite efforts to diagnose CWD from alternative specimens, gastroscopy with duodenal biopsy and subsequent histological and molecular–biological examination is the most reliable diagnostic tool for CWD. PMID:25881849

  13. Screening in toddlers and preschoolers at risk for autism spectrum disorder: Evaluating a novel mobile-health screening tool.

    PubMed

    Kanne, Stephen M; Carpenter, Laura Arnstein; Warren, Zachary

    2018-05-07

    There are many available tools with varying levels of accuracy designed to screen for Autism Spectrum Disorder (ASD) in young children, both in the general population and specifically among those referred for developmental concerns. With burgeoning waitlists for comprehensive diagnostic ASD assessments, finding accurate methods and tools for advancing diagnostic triage becomes increasingly important. The current study compares the efficacy of four oft used paper and pencil measures, the Modified Checklist for Autism in Toddlers Revised with Follow-up, the Social Responsiveness Scale, Second Edition, and the Social Communication Questionnaire, and the Child Behavior Checklist to a novel mobile-health screening tool developed by Cognoa, Inc. (Cognoa) in a group of children 18-72 months of age. The Cognoa tool may have potential benefits as it integrates a series of parent-report questions with remote clinical ratings of brief video segments uploaded via parent's smartphones to calculate level of ASD risk. Participants were referred to one of three tertiary care diagnostic centers for ASD-related concerns (n = 230) and received a best estimate ASD diagnosis. Analysis and comparison of psychometric properties indicated potential advantages for Cognoa within this clinical sample across age ranges not often covered by another single measure/tool. Autism Res 2018. © 2018 International Society for Autism Research, Wiley Periodicals, Inc. With the wait times getting longer for comprehensive Autism Spectrum Disorder (ASD) diagnostic assessments, it is becoming increasingly important to find accurate tools to screen for ASD. The current study compares four screening measures that have been in use for some time to a novel mobile-health screening tool, called Cognoa. The Cognoa tool is novel because it integrates parent-report questions with clinical ratings of brief video segments uploaded via parent's smartphones to calculate ASD risk. Two hundred thirty children who were referred to one of three ASD specialty diagnostic centers to see if they had ASD participated in the study. A direct comparison indicated potential advantages for Cognoa not often covered by another single measure/tool. © 2018 International Society for Autism Research, Wiley Periodicals, Inc.

  14. Diagnostic Accuracy of Repetition Tasks for the Identification of Specific Language Impairment (SLI) in Bilingual Children: Evidence from Russian and Hebrew

    ERIC Educational Resources Information Center

    Armon-Lotem, Sharon; Meir, Natalia

    2016-01-01

    Background: Previous research demonstrates that repetition tasks are valuable tools for diagnosing specific language impairment (SLI) in monolingual children in English and a variety of other languages, with non-word repetition (NWR) and sentence repetition (SRep) yielding high levels of sensitivity and specificity. Yet, only a few studies have…

  15. VRUSE--a computerised diagnostic tool: for usability evaluation of virtual/synthetic environment systems.

    PubMed

    Kalawsky, R S

    1999-02-01

    A special questionnaire (VRUSE) has been designed to measure the usability of a VR system according to the attitude and perception of its users. Important aspects of VR systems were carefully derived to produce key usability factors for the questionnaire. Unlike questionnaires designed for generic interfaces VRUSE is specifically designed to cater for evaluating virtual environments, being a diagnostic tool providing a wealth of information about a user's viewpoint of the interface. VRUSE can be used to great effect with other evaluation techniques to pinpoint problematical areas of a VR interface. Other applications include bench-marking of competitor VR systems.

  16. A simulation study to quantify the impacts of exposure ...

    EPA Pesticide Factsheets

    A simulation study to quantify the impacts of exposure measurement error on air pollution health risk estimates in copollutant time-series models The National Exposure Research Laboratory (NERL) Computational Exposure Division (CED) develops and evaluates data, decision-support tools, and models to be applied to media-specific or receptor-specific problem areas. CED uses modeling-based approaches to characterize exposures, evaluate fate and transport, and support environmental diagnostics/forensics with input from multiple data sources. It also develops media- and receptor-specific models, process models, and decision support tools for use both within and outside of EPA.

  17. eap Gene as novel target for specific identification of Staphylococcus aureus.

    PubMed

    Hussain, Muzaffar; von Eiff, Christof; Sinha, Bhanu; Joost, Insa; Herrmann, Mathias; Peters, Georg; Becker, Karsten

    2008-02-01

    The cell surface-associated extracellular adherence protein (Eap) mediates adherence of Staphylococcus aureus to host extracellular matrix components and inhibits inflammation, wound healing, and angiogenesis. A well-characterized collection of S. aureus and non-S. aureus staphylococcal isolates (n = 813) was tested for the presence of the Eap-encoding gene (eap) by PCR to investigate the use of the eap gene as a specific diagnostic tool for identification of S. aureus. Whereas all 597 S. aureus isolates were eap positive, this gene was not detectable in 216 non-S. aureus staphylococcal isolates comprising 47 different species and subspecies of coagulase-negative staphylococci and non-S. aureus coagulase-positive or coagulase-variable staphylococci. Furthermore, non-S. aureus isolates did not express Eap homologs, as verified on the transcriptional and protein levels. Based on these data, the sensitivity and specificity of the newly developed PCR targeting the eap gene were both 100%. Thus, the unique occurrence of Eap in S. aureus offers a promising tool particularly suitable for molecular diagnostics of this pathogen.

  18. Evaluation of diagnostic tools that tertiary teachers can apply to profile their students' conceptions

    NASA Astrophysics Data System (ADS)

    Schultz, Madeleine; Lawrie, Gwendolyn A.; Bailey, Chantal H.; Bedford, Simon B.; Dargaville, Tim R.; O'Brien, Glennys; Tasker, Roy; Thompson, Christopher D.; Williams, Mark; Wright, Anthony H.

    2017-03-01

    A multi-institution collaborative team of Australian chemistry education researchers, teaching a total of over 3000 first year chemistry students annually, has explored a tool for diagnosing students' prior conceptions as they enter tertiary chemistry courses. Five core topics were selected and clusters of diagnostic items were assembled linking related concepts in each topic together. An ordered multiple choice assessment strategy was adopted to enable provision of formative feedback to students through combination of the specific distractors that they chose. Concept items were either sourced from existing research instruments or developed by the project team. The outcome is a diagnostic tool consisting of five topic clusters of five concept items that has been delivered in large introductory chemistry classes at five Australian institutions. Statistical analysis of data has enabled exploration of the composition and validity of the instrument including a comparison between delivery of the complete 25 item instrument with subsets of five items, clustered by topic. This analysis revealed that most items retained their validity when delivered in small clusters. Tensions between the assembly, validation and delivery of diagnostic instruments for the purposes of acquiring robust psychometric research data versus their pragmatic use are considered in this study.

  19. Computational diagnosis of canine lymphoma

    NASA Astrophysics Data System (ADS)

    Mirkes, E. M.; Alexandrakis, I.; Slater, K.; Tuli, R.; Gorban, A. N.

    2014-03-01

    One out of four dogs will develop cancer in their lifetime and 20% of those will be lymphoma cases. PetScreen developed a lymphoma blood test using serum samples collected from several veterinary practices. The samples were fractionated and analysed by mass spectrometry. Two protein peaks, with the highest diagnostic power, were selected and further identified as acute phase proteins, C-Reactive Protein and Haptoglobin. Data mining methods were then applied to the collected data for the development of an online computer-assisted veterinary diagnostic tool. The generated software can be used as a diagnostic, monitoring and screening tool. Initially, the diagnosis of lymphoma was formulated as a classification problem and then later refined as a lymphoma risk estimation. Three methods, decision trees, kNN and probability density evaluation, were used for classification and risk estimation and several preprocessing approaches were implemented to create the diagnostic system. For the differential diagnosis the best solution gave a sensitivity and specificity of 83.5% and 77%, respectively (using three input features, CRP, Haptoglobin and standard clinical symptom). For the screening task, the decision tree method provided the best result, with sensitivity and specificity of 81.4% and >99%, respectively (using the same input features). Furthermore, the development and application of new techniques for the generation of risk maps allowed their user-friendly visualization.

  20. Comparison of Diagnostic Performance of Semi-Quantitative Knee Ultrasound and Knee Radiography with MRI: Oulu Knee Osteoarthritis Study.

    PubMed

    Podlipská, Jana; Guermazi, Ali; Lehenkari, Petri; Niinimäki, Jaakko; Roemer, Frank W; Arokoski, Jari P; Kaukinen, Päivi; Liukkonen, Esa; Lammentausta, Eveliina; Nieminen, Miika T; Tervonen, Osmo; Koski, Juhani M; Saarakkala, Simo

    2016-03-01

    Osteoarthritis (OA) is a common degenerative musculoskeletal disease highly prevalent in aging societies worldwide. Traditionally, knee OA is diagnosed using conventional radiography. However, structural changes of articular cartilage or menisci cannot be directly evaluated using this method. On the other hand, ultrasound is a promising tool able to provide direct information on soft tissue degeneration. The aim of our study was to systematically determine the site-specific diagnostic performance of semi-quantitative ultrasound grading of knee femoral articular cartilage, osteophytes and meniscal extrusion, and of radiographic assessment of joint space narrowing and osteophytes, using MRI as a reference standard. Eighty asymptomatic and 79 symptomatic subjects with mean age of 57.7 years were included in the study. Ultrasound performed best in the assessment of femoral medial and lateral osteophytes, and medial meniscal extrusion. In comparison to radiography, ultrasound performed better or at least equally well in identification of tibio-femoral osteophytes, medial meniscal extrusion and medial femoral cartilage morphological degeneration. Ultrasound provides relevant additional diagnostic information on tissue-specific morphological changes not depicted by conventional radiography. Consequently, the use of ultrasound as a complementary imaging tool along with radiography may enable more accurate and cost-effective diagnostics of knee osteoarthritis at the primary healthcare level.

  1. A new biomarker panel in bronchoalveolar lavage for an improved lung cancer diagnosis.

    PubMed

    Uribarri, María; Hormaeche, Itsaso; Zalacain, Rafael; Lopez-Vivanco, Guillermo; Martinez, Antonio; Nagore, Daniel; Ruiz-Argüello, M Begoña

    2014-10-01

    The enormous biological complexity and high mortality rate of lung cancer highlights the need for new global approaches for the discovery of reliable early diagnostic biomarkers. The study of bronchoalveolar lavage samples by proteomic techniques could identify new lung cancer biomarkers and may provide promising noninvasive diagnostic tools able to enhance the sensitivity of current methods. First, an observational prospective study was designed to assess protein expression differences in bronchoalveolar lavages from patients with (n = 139) and without (n = 49) lung cancer, using two-dimensional gel electrophoresis and subsequent protein identification by mass spectrometry. Second, validation of candidate biomarkers was performed by bead-based immunoassays with a different patient cohort (204 patients, 48 controls). Thirty-two differentially expressed proteins were identified in bronchoalveolar lavages, 10 of which were confirmed by immunoassays. The expression levels of APOA1, CO4A, CRP, GSTP1, and SAMP led to a lung cancer diagnostic panel that reached 95% sensitivity and 81% specificity, and the quantification of STMN1 and GSTP1 proteins allowed the two main lung cancer subtypes to be discriminated with 90% sensitivity and 57% specificity. Bronchoalveolar lavage represents a promising noninvasive source of lung cancer specific protein biomarkers with high diagnostic accuracy. Measurement of APOA1, CO4A, CRP, GSTP1, SAMP, and STMN1 in this fluid may be a useful tool for lung cancer diagnosis, although a further validation in a larger clinical set is required for early stages.

  2. Acquaintance to Artificial Neural Networks and use of artificial intelligence as a diagnostic tool for tuberculosis: A review.

    PubMed

    Dande, Payal; Samant, Purva

    2018-01-01

    Tuberculosis [TB] has afflicted numerous nations in the world. As per a report by the World Health Organization [WHO], an estimated 1.4 million TB deaths in 2015 and an additional 0.4 million deaths resulting from TB disease among people living with HIV, were observed. Most of the TB deaths can be prevented if it is detected at an early stage. The existing processes of diagnosis like blood tests or sputum tests are not only tedious but also take a long time for analysis and cannot differentiate between different drug resistant stages of TB. The need to find newer prompt methods for disease detection has been aided by the latest Artificial Intelligence [AI] tools. Artificial Neural Network [ANN] is one of the important tools that is being used widely in diagnosis and evaluation of medical conditions. This review aims at providing brief introduction to various AI tools that are used in TB detection and gives a detailed description about the utilization of ANN as an efficient diagnostic technique. The paper also provides a critical assessment of ANN and the existing techniques for their diagnosis of TB. Researchers and Practitioners in the field are looking forward to use ANN and other upcoming AI tools such as Fuzzy-logic, genetic algorithms and artificial intelligence simulation as a promising current and future technology tools towards tackling the global menace of Tuberculosis. Latest advancements in the diagnostic field include the combined use of ANN with various other AI tools like the Fuzzy-logic, which has led to an increase in the efficacy and specificity of the diagnostic techniques. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Near Infrared Imaging as a Diagnostic Tool for Detecting Enamel Demineralization: An in vivo Study

    NASA Astrophysics Data System (ADS)

    Lucas, Seth Adam

    Background and Objectives: For decades there has been an effort to develop alternative optical methods of imaging dental decay utilizing non-ionizing radiation methods. The purpose of this in-vivo study was to demonstrate whether NIR can be used as a diagnostic tool to evaluate dental caries and to compare the sensitivity and specificity of this method with that of conventional methods, including bitewing x-rays and visual inspection. Materials and Methods: 31 test subjects (n=31) from the UCSF orthodontic clinic undergoing orthodontic treatment with planned premolar extractions were recruited. Calibrated examiners performed caries detection examinations using conventional methods: bitewing radiographs and visual inspection. These findings were compared with the results from NIR examinations: transillumination and reflectance. To confirm the results found in the two different detection methods, a gold standard was used. After teeth were extracted, polarized light microscopy and transverse microradiography were performed. Results: A total of 87 premolars were used in the study. NIR identified the occlusal lesions with a sensitivity of 71% and a specificity of 77%, whereas, the visual examination had a sensitivity of only 40% and a specifity of 39%. For interproximal lesions halfway to DEJ, specificity remained constant, but sensitivity improved to 100% for NIR and 75% for x-rays. Conclusions: The results of this preliminary study demonstrate that NIR is just as effective at detecting enamel interproximal lesions as standard dental x-rays. NIR was more effective at detecting occlusal lesions than visual examination alone. NIR shows promise as an alternative diagnostic tool to the conventional methods of x-rays and visual examination and provides a non-ionizing radiation technique.

  4. Case-Deletion Diagnostics for Maximum Likelihood Multipoint Quantitative Trait Locus Linkage Analysis

    PubMed Central

    Mendoza, Maria C.B.; Burns, Trudy L.; Jones, Michael P.

    2009-01-01

    Objectives Case-deletion diagnostic methods are tools that allow identification of influential observations that may affect parameter estimates and model fitting conclusions. The goal of this paper was to develop two case-deletion diagnostics, the exact case deletion (ECD) and the empirical influence function (EIF), for detecting outliers that can affect results of sib-pair maximum likelihood quantitative trait locus (QTL) linkage analysis. Methods Subroutines to compute the ECD and EIF were incorporated into the maximum likelihood QTL variance estimation components of the linkage analysis program MAPMAKER/SIBS. Performance of the diagnostics was compared in simulation studies that evaluated the proportion of outliers correctly identified (sensitivity), and the proportion of non-outliers correctly identified (specificity). Results Simulations involving nuclear family data sets with one outlier showed EIF sensitivities approximated ECD sensitivities well for outlier-affected parameters. Sensitivities were high, indicating the outlier was identified a high proportion of the time. Simulations also showed the enormous computational time advantage of the EIF. Diagnostics applied to body mass index in nuclear families detected observations influential on the lod score and model parameter estimates. Conclusions The EIF is a practical diagnostic tool that has the advantages of high sensitivity and quick computation. PMID:19172086

  5. Development and application of a universal Hemoplasma screening assay based on the SYBR green PCR principle.

    PubMed

    Willi, Barbara; Meli, Marina L; Lüthy, Ruedi; Honegger, Hanspeter; Wengi, Nicole; Hoelzle, Ludwig E; Reusch, Claudia E; Lutz, Hans; Hofmann-Lehmann, Regina

    2009-12-01

    Hemotropic mycoplasmas (hemoplasmas) are the causative agents of infectious anemia in several mammalian species. Their zoonotic potential has recently been substantiated by the identification of a feline hemoplasma isolate in an immunocompromised human patient. Although species-specific diagnostic molecular methods have been developed, their application as screening tools is limited due to the species diversity of hemoplasmas. The goals of this study were to develop a universal hemoplasma screening assay with broad specificity based on the SYBR green PCR principle, to compare the assay with hemoplasma-specific TaqMan PCR, and to analyze potential tick vectors and human blood samples to address the zoonotic potential. The newly developed PCR assay based on the 16S rRNA gene amplified feline, canine, bovine, porcine, camelid, and murine hemoplasmas, as well as Mycoplasma penetrans and Mycoplasma pneumoniae. The lower detection limit for feline and canine hemoplasmas was 1 to 10 copies/PCR. The assay exhibited 98.2% diagnostic sensitivity and 92.1% diagnostic specificity for feline hemoplasmas. All 1,950 Ixodes ticks were PCR negative, suggesting that Ixodes ticks are not relevant vectors for the above-mentioned hemoplasma species in Switzerland. None of the 414 blood samples derived from anemic or immunocompromised human patients revealed a clear positive result. The SYBR green PCR assay described here is a suitable tool to screen for known and so-far-undiscovered hemoplasma species. Positive results should be confirmed by specific TaqMan PCR or sequencing.

  6. Combining magnetic nanoparticle with biotinylated nanobodies for rapid and sensitive detection of influenza H3N2

    PubMed Central

    2014-01-01

    Our objective is to develop a rapid and sensitive assay based on magnetic beads to detect the concentration of influenza H3N2. The possibility of using variable domain heavy-chain antibodies (nanobody) as diagnostic tools for influenza H3N2 was investigated. A healthy camel was immunized with inactivated influenza H3N2. A nanobody library of 8 × 108 clones was constructed and phage displayed. After three successive biopanning steps, H3N2-specific nanobodies were successfully isolated, expressed in Escherichia coli, and purified. Sequence analysis of the nanobodies revealed that we possessed four classes of nanobodies against H3N2. Two nanobodies were further used to prepare our rapid diagnostic kit. Biotinylated nanobody was effectively immobilized onto the surface of streptavidin magnetic beads. The modified magnetic beads with nanobody capture specifically influenza H3N2 and can still be recognized by nanobodies conjugated to horseradish peroxidase (HRP) conjugates. Under optimized conditions, the present immunoassay exhibited a relatively high sensitive detection with a limit of 50 ng/mL. In conclusion, by combining magnetic beads with specific nanobodies, this assay provides a promising influenza detection assay to develop a potential rapid, sensitive, and low-cost diagnostic tool to screen for influenza infections. PMID:25328501

  7. Combining magnetic nanoparticle with biotinylated nanobodies for rapid and sensitive detection of influenza H3N2

    NASA Astrophysics Data System (ADS)

    Zhu, Min; Hu, Yonghong; Li, Guirong; Ou, Weijun; Mao, Panyong; Xin, Shaojie; Wan, Yakun

    2014-09-01

    Our objective is to develop a rapid and sensitive assay based on magnetic beads to detect the concentration of influenza H3N2. The possibility of using variable domain heavy-chain antibodies (nanobody) as diagnostic tools for influenza H3N2 was investigated. A healthy camel was immunized with inactivated influenza H3N2. A nanobody library of 8 × 108 clones was constructed and phage displayed. After three successive biopanning steps, H3N2-specific nanobodies were successfully isolated, expressed in Escherichia coli, and purified. Sequence analysis of the nanobodies revealed that we possessed four classes of nanobodies against H3N2. Two nanobodies were further used to prepare our rapid diagnostic kit. Biotinylated nanobody was effectively immobilized onto the surface of streptavidin magnetic beads. The modified magnetic beads with nanobody capture specifically influenza H3N2 and can still be recognized by nanobodies conjugated to horseradish peroxidase (HRP) conjugates. Under optimized conditions, the present immunoassay exhibited a relatively high sensitive detection with a limit of 50 ng/mL. In conclusion, by combining magnetic beads with specific nanobodies, this assay provides a promising influenza detection assay to develop a potential rapid, sensitive, and low-cost diagnostic tool to screen for influenza infections.

  8. Malaria attacks due to P. vivax or P. ovale in two French military teaching hospitals (2000 to 2009).

    PubMed

    Demaison, X; Rapp, C; de Laval, F; Simon, F

    2013-04-01

    Non-falciparum malaria is less studied than Plasmodium falciparum malaria, both in endemic and non-endemic zones. A retrospective study was made of the medical files of patients managed for attacks of malaria due to Plasmodium vivax or Plasmodium ovale, between 2000 and 2009, in two French military teaching hospitals. Seventy-five percent of attacks occurred after a stay in French Guiana, in the Comoros Archipelago, or in the Ivory Coast Republic. The most frequent symptoms two months after coming back were a flu-like syndrome with headaches, and occasional digestive symptoms, without any difference between the first attack and recurrence. One third of patients presented with anemia, 78% with thrombocytopenia, and 12% with liver dysfunction. This study was the most important made in France on imported non-falciparum malaria. Military patients and immigrants accounted for a majority of patients due to the specificity of military hospitals and local recruitment. Clinical and biological features were not specific and did not allow guiding the diagnosis. Diagnostic tools were less sensitive for P. ovale. Patient management could be optimized by more efficient diagnostic tools, specific guidelines for the diagnostic and therapeutic management, and a dedicated medical training for family practitioners as well as hospitals practice. Copyright © 2013. Published by Elsevier SAS.

  9. Current ante-mortem techniques for diagnosis of bovine tuberculosis.

    PubMed

    Bezos, Javier; Casal, Carmen; Romero, Beatriz; Schroeder, Bjoern; Hardegger, Roland; Raeber, Alex J; López, Lissette; Rueda, Paloma; Domínguez, Lucas

    2014-10-01

    Bovine tuberculosis (TB), mainly caused by Mycobacterium bovis, is a zoonotic disease with implications for Public Health and having an economic impact due to decreased production and limitations to the trade. Bovine TB is subjected to official eradication campaigns mainly based on a test and slaughter policy using diagnostic assays based on the cell-mediated immune response as the intradermal tuberculin test and the gamma-interferon (IFN-γ) assay. Moreover, several diagnostic assays based on the detection of specific antibodies (Abs) have been developed in the last few years with the aim of complementing the current diagnostic techniques in the near future. This review provides an overview of the current ante-mortem diagnostic tools for diagnosis of bovine TB regarding historical background, methodologies and sensitivity (Se) and specificity (Sp) obtained in previous studies under different epidemiological situations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Protein electrophoresis as a diagnostic and prognostic tool in raptor medicine.

    PubMed

    Tatum, L M; Zaias, J; Mealey, B K; Cray, C; Bossart, G D

    2000-12-01

    Plasma proteins of 139 healthy adult birds of prey from 10 species were separated by electrophoresis to characterize and document normal reference ranges and species-specific electrophoretic patternsand to evaluate the value of this technique for health screening, disease diagnosis, and prognostic indication. Species studied included bald eagle (Haliaeetus leucocephalus), red-tailed hawk (Buteo jamaicensis), barn owl (Tyto alba), great horned owl (Bubo virginianus), turkey vulture (Cathartes aura), Harris' hawk (Parabuteo unicinctus), Stellar's sea eagle (Haliaeetus pelagicus), barred owl (Strix varia), screech owl (Otus asio), and black vulture (Coragyps atratus). Several clinical cases show the diagnostic/therapeutic value of protein electrophoresis in raptors. This study establishes species-specific reference ranges for several birds of prey and discusses the benefit of electrophoresis as a diagnostic technique in health screens, as a diagnostic aid in conjunction with other tests, and as a prognostic indicator in clinical evaluation of raptors.

  11. [Laboratory diagnostics of urogenital clamidiosis].

    PubMed

    Churakov, A A; Kulichenko, A N; Kzakova, E S; Serebrianik, N E; Suvorov, A P; Kutyrev, V V; Glybochko, P V

    2005-02-01

    Laboratory diagnostic tools of urogenital clamidiosis--PCR, ELISA (IgG and IgM) and direct immunofluorescence (DIF)--were comparatively analyzed. The positive PCR result was checked by another PCR test with a different primer; 5 false positive responses were registered (specificity 99.6%). As against PCR, the sensitivity of ELISA made 53%, its specificity -75.5%, the diagnostic value of positive result -58%, the diagnostic value of negative result -71.6% and the diagnostics accuracy -66.7%. The respective DIF parameters were as follows: 36%, 90%, 81.5%, 54.2% and 60.9%. A high rate of detection (above 90%) of the conditionally pathogenic microflora associated with Chlamydia trachomatis (above 110 microbe cells/ml) was pointed out. Hardnerelli and ureaplasms were more often found in female smears, staphylococci and enterococci--in male sperm. It is underlined as important to hold complex examinations for Chlamidia (PCR, ELISA and DIC as an additional test) combined with bacteriological quantification of the conditionally pathogenic microflora and determination of its resistance to antibiotics.

  12. Software Tools to Support the Assessment of System Health

    NASA Technical Reports Server (NTRS)

    Melcher, Kevin J.

    2013-01-01

    This presentation provides an overview of three software tools that were developed by the NASA Glenn Research Center to support the assessment of system health: the Propulsion Diagnostic Method Evaluation Strategy (ProDIMES), the Systematic Sensor Selection Strategy (S4), and the Extended Testability Analysis (ETA) tool. Originally developed to support specific NASA projects in aeronautics and space, these software tools are currently available to U.S. citizens through the NASA Glenn Software Catalog. The ProDiMES software tool was developed to support a uniform comparison of propulsion gas path diagnostic methods. Methods published in the open literature are typically applied to dissimilar platforms with different levels of complexity. They often address different diagnostic problems and use inconsistent metrics for evaluating performance. As a result, it is difficult to perform a one ]to ]one comparison of the various diagnostic methods. ProDIMES solves this problem by serving as a theme problem to aid in propulsion gas path diagnostic technology development and evaluation. The overall goal is to provide a tool that will serve as an industry standard, and will truly facilitate the development and evaluation of significant Engine Health Management (EHM) capabilities. ProDiMES has been developed under a collaborative project of The Technical Cooperation Program (TTCP) based on feedback provided by individuals within the aircraft engine health management community. The S4 software tool provides a framework that supports the optimal selection of sensors for health management assessments. S4 is structured to accommodate user ]defined applications, diagnostic systems, search techniques, and system requirements/constraints. One or more sensor suites that maximize this performance while meeting other user ]defined system requirements that are presumed to exist. S4 provides a systematic approach for evaluating combinations of sensors to determine the set or sets of sensors that optimally meet the performance goals and the constraints. It identifies optimal sensor suite solutions by utilizing a merit (i.e., cost) function with one of several available optimization approaches. As part of its analysis, S4 can expose fault conditions that are difficult to diagnose due to an incomplete diagnostic philosophy and/or a lack of sensors. S4 was originally developed and applied to liquid rocket engines. It was subsequently used to study the optimized selection of sensors for a simulation ]based aircraft engine diagnostic system. The ETA Tool is a software ]based analysis tool that augments the testability analysis and reporting capabilities of a commercial ]off ]the ]shelf (COTS) package. An initial diagnostic assessment is performed by the COTS software using a user ]developed, qualitative, directed ]graph model of the system being analyzed. The ETA Tool accesses system design information captured within the model and the associated testability analysis output to create a series of six reports for various system engineering needs. These reports are highlighted in the presentation. The ETA Tool was developed by NASA to support the verification of fault management requirements early in the Launch Vehicle process. Due to their early development during the design process, the TEAMS ]based diagnostic model and the ETA Tool were able to positively influence the system design by highlighting gaps in failure detection, fault isolation, and failure recovery.

  13. Autism Spectrum Disorder in Anorexia Nervosa: An Updated Literature Review.

    PubMed

    Westwood, Heather; Tchanturia, Kate

    2017-07-01

    There is growing interest in the relationship between anorexia nervosa (AN) and autism spectrum disorder (ASD). This review aimed to synthesise the most recent research on this topic to identify gaps in current knowledge, directions for future research and reflect on implications for treatment. Eight studies assessing the presence of ASD in AN were identified in the literature along with three studies examining the impact of symptoms of ASD on treatment outcome. Research with young people and using parental-report measures suggest lower rates of co-morbidity than previous adult studies. The wide range of diagnostic tools, methodologies and populations studied make it difficult to determine the prevalence of ASD in AN. Despite this, studies consistently report over-representation of symptoms of ASD in AN. Co-morbid AN and ASD may require more intensive treatment or specifically tailored interventions. Future longitudinal research and female-specific diagnostic tools would help elucidate the relationship between these two disorders.

  14. The diagnostic value of polymerase chain reaction for Mycobacterium tuberculosis to distinguish intestinal tuberculosis from crohn's disease: A meta-analysis.

    PubMed

    Jin, Ting; Fei, Baoying; Zhang, Yu; He, Xujun

    2017-01-01

    Intestinal tuberculosis (ITB) and Crohn's disease (CD) are important differential diagnoses that can be difficult to distinguish. Polymerase chain reaction (PCR) for Mycobacterium tuberculosis (MTB) is an efficient and promising tool. This meta-analysis was performed to systematically and objectively assess the potential diagnostic accuracy and clinical value of PCR for MTB in distinguishing ITB from CD. We searched PubMed, Embase, Web of Science, Science Direct, and the Cochrane Library for eligible studies, and nine articles with 12 groups of data were identified. The included studies were subjected to quality assessment using the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. The summary estimates were as follows: sensitivity 0.47 (95% CI: 0.42-0.51); specificity 0.95 (95% CI: 0.93-0.97); the positive likelihood ratio (PLR) 10.68 (95% CI: 6.98-16.35); the negative likelihood ratio (NLR) 0.49 (95% CI: 0.33-0.71); and diagnostic odds ratio (DOR) 21.92 (95% CI: 13.17-36.48). The area under the curve (AUC) was 0.9311, with a Q* value of 0.8664. Heterogeneity was found in the NLR. The heterogeneity of the studies was evaluated by meta-regression analysis and subgroup analysis. The current evidence suggests that PCR for MTB is a promising and highly specific diagnostic method to distinguish ITB from CD. However, physicians should also keep in mind that negative results cannot exclude ITB for its low sensitivity. Additional prospective studies are needed to further evaluate the diagnostic accuracy of PCR.

  15. Diagnostic methods for assessing maxillary skeletal and dental transverse deficiencies: A systematic review

    PubMed Central

    Sawchuk, Dena; Currie, Kris; Vich, Manuel Lagravere; Palomo, Juan Martin

    2016-01-01

    Objective To evaluate the accuracy and reliability of the diagnostic tools available for assessing maxillary transverse deficiencies. Methods An electronic search of three databases was performed from their date of establishment to April 2015, with manual searching of reference lists of relevant articles. Articles were considered for inclusion if they reported the accuracy or reliability of a diagnostic method or evaluation technique for maxillary transverse dimensions in mixed or permanent dentitions. Risk of bias was assessed in the included articles, using the Quality Assessment of Diagnostic Accuracy Studies tool-2. Results Nine articles were selected. The studies were heterogeneous, with moderate to low methodological quality, and all had a high risk of bias. Four suggested that the use of arch width prediction indices with dental cast measurements is unreliable for use in diagnosis. Frontal cephalograms derived from cone-beam computed tomography (CBCT) images were reportedly more reliable for assessing intermaxillary transverse discrepancies than posteroanterior cephalograms. Two studies proposed new three-dimensional transverse analyses with CBCT images that were reportedly reliable, but have not been validated for clinical sensitivity or specificity. No studies reported sensitivity, specificity, positive or negative predictive values or likelihood ratios, or ROC curves of the methods for the diagnosis of transverse deficiencies. Conclusions Current evidence does not enable solid conclusions to be drawn, owing to a lack of reliable high quality diagnostic studies evaluating maxillary transverse deficiencies. CBCT images are reportedly more reliable for diagnosis, but further validation is required to confirm CBCT's accuracy and diagnostic superiority. PMID:27668196

  16. PIVKA-II is a useful tool for diagnostic characterization of ultrasound-detected liver nodules in cirrhotic patients

    PubMed Central

    Saitta, Carlo; Raffa, Giuseppina; Alibrandi, Angela; Brancatelli, Santa; Lombardo, Daniele; Tripodi, Gianluca; Raimondo, Giovanni; Pollicino, Teresa

    2017-01-01

    Abstract Protein induced by vitamin K absence-II (PIVKA-II) is a potential screening marker for hepatocellular carcinoma (HCC). Limited data are available about its utility in discriminating neoplastic from regenerative nodules at ultrasonography (US) evaluation in cirrhotic patients. Aim of this study was to investigate the diagnostic utility of PIVKA-II in cases showing liver nodules of uncertain diagnosis at US. Ninety cirrhotics with US evidence of liver nodule(s) were enrolled. All patients underwent blood sampling within 1 week of US and were thereafter followed up. HCC was confirmed in 40/90 cases, and in all cases it was in a very early/early stage. All sera were tested for PIVKA-II and alpha-fetoprotein (AFP) at the end of follow-up. PIVKA-II at a cut off of 60 mAU/mL was significantly associated with HCC at both univariate and multivariate analysis (P = .016 and P = .032, respectively). AFP at a cut off of 6.5 ng/mL was not associated with HCC at univariate analysis (P = .246). ROC curves showed that PIVKA-II had 60% sensitivity, 88% specificity, 80% positive predictive value (PPV), and 73% negative predictive value (NPV), whereas AFP had 67% sensitivity, 68% specificity, 63% PPV, and 72% NPV. AUROC curves showed that the combination of both biomarkers increased the diagnostic accuracy for HCC (AUC 0.76; sensitivity 70%, specificity 94%, PPV 91%, and NPV 79%). In conclusion, PIVKA-II is a useful tool for the diagnostic definition of US-detected liver nodules in cirrhotic patients, and it provides high diagnostic accuracy for HCC when combined with AFP. PMID:28658121

  17. Accuracy of Brief Screening Tools for Identifying Postpartum Depression Among Adolescent Mothers

    PubMed Central

    Venkatesh, Kartik K.; Zlotnick, Caron; Triche, Elizabeth W.; Ware, Crystal

    2014-01-01

    OBJECTIVE: To evaluate the accuracy of the Edinburgh Postnatal Depression Scale (EPDS) and 3 subscales for identifying postpartum depression among primiparous adolescent mothers. METHODS: Mothers enrolled in a randomized controlled trial to prevent postpartum depression completed a psychiatric diagnostic interview and the 10-item EPDS at 6 weeks, 3 months, and 6 months postpartum. Three subscales of the EPDS were assessed as brief screening tools: 3-item anxiety subscale (EPDS-3), 7-item depressive symptoms subscale (EPDS-7), and 2-item subscale (EPDS-2) that resemble the Patient Health Questionnaire-2. Receiver operating characteristic curves and the areas under the curves for each tool were compared to assess accuracy. The sensitivities and specificities of each screening tool were calculated in comparison with diagnostic criteria for a major depressive disorder. Repeated-measures longitudinal analytical techniques were used. RESULTS: A total of 106 women contributed 289 postpartum visits; 18% of the women met criteria for incident postpartum depression by psychiatric diagnostic interview. When used as continuous measures, the full EPDS, EPDS-7, and EPDS-2 performed equally well (area under the curve >0.9). Optimal cutoff scores for a positive depression screen for the EPDS and EPDS-7 were lower (≥9 and ≥7, respectively) than currently recommended cutoff scores (≥10). At optimal cutoff scores, the EPDS and EPDS-7 both had sensitivities of 90% and specificities of >85%. CONCLUSIONS: The EPDS, EPDS-7, and EPDS-2 are highly accurate at identifying postpartum depression among adolescent mothers. In primary care pediatric settings, the EPDS and its shorter subscales have potential for use as effective depression screening tools. PMID:24344102

  18. The PHQ-PD as a Screening Tool for Panic Disorder in the Primary Care Setting in Spain

    PubMed Central

    Wood, Cristina Mae; Ruíz-Rodríguez, Paloma; Tomás-Tomás, Patricia; Gracia-Gracia, Irene; Dongil-Collado, Esperanza; Iruarrizaga, M. Iciar

    2016-01-01

    Introduction Panic disorder is a common anxiety disorder and is highly prevalent in Spanish primary care centres. The use of validated tools can improve the detection of panic disorder in primary care populations, thus enabling referral for specialized treatment. The aim of this study is to determine the accuracy of the Patient Health Questionnaire-Panic Disorder (PHQ-PD) as a screening and diagnostic tool for panic disorder in Spanish primary care centres. Method We compared the psychometric properties of the PHQ-PD to the reference standard, the Structured Clinical Interview for DSM-IV Axis I Disorders (SCID-I) interview. General practitioners referred 178 patients who completed the entire PHQ test, including the PHQ-PD, to undergo the SCID-I. The sensitivity, specificity, positive and negative predictive values and positive and negative likelihood ratios of the PHQ-PD were assessed. Results The operating characteristics of the PHQ-PD are moderate. The best cut-off score was 5 (sensitivity .77, specificity .72). Modifications to the questionnaire's algorithms improved test characteristics (sensitivity .77, specificity .72) compared to the original algorithm. The screening question alone yielded the highest sensitivity score (.83). Conclusion Although the modified algorithm of the PHQ-PD only yielded moderate results as a diagnostic test for panic disorder, it was better than the original. Using only the first question of the PHQ-PD showed the best psychometric properties (sensitivity). Based on these findings, we suggest the use of the screening questions for screening purposes and the modified algorithm for diagnostic purposes. PMID:27525977

  19. Application of the denaturing gradient gel electrophoresis (DGGE) technique as an efficient diagnostic tool for ciliate communities in soil.

    PubMed

    Jousset, Alexandre; Lara, Enrique; Nikolausz, Marcell; Harms, Hauke; Chatzinotas, Antonis

    2010-02-01

    Ciliates (or Ciliophora) are ubiquitous organisms which can be widely used as bioindicators in ecosystems exposed to anthropogenic and industrial influences. The evaluation of the environmental impact on soil ciliate communities with methods relying on morphology-based identification may be hampered by the large number of samples usually required for a statistically supported, reliable conclusion. Cultivation-independent molecular-biological diagnostic tools are a promising alternative to greatly simplify and accelerate such studies. In this present work a ciliate-specific fingerprint method based on the amplification of a phylogenetic marker gene (i.e. the 18S ribosomal RNA gene) with subsequent analysis by denaturing gradient gel electrophoresis (DGGE) was developed and used to monitor community shifts in a polycyclic aromatic hydrocarbon (PAH) polluted soil. The semi-nested approach generated ciliate-specific amplification products from all soil samples and allowed to distinguish community profiles from a PAH-polluted and a non-polluted control soil. Subsequent sequence analysis of excised bands provided evidence that polluted soil samples are dominated by organisms belonging to the class Colpodea. The general DGGE approach presented in this study might thus in principle serve as a fast and reproducible diagnostic tool, complementing and facilitating future ecological and ecotoxicological monitoring of ciliates in polluted habitats. Copyright 2009 Elsevier B.V. All rights reserved.

  20. The utility of clinical decision tools for diagnosing osteoporosis in postmenopausal women with rheumatoid arthritis

    PubMed Central

    Brand, Caroline; Lowe, Adrian; Hall, Stephen

    2008-01-01

    Background Patients with rheumatoid arthritis have a higher risk of low bone mineral density than normal age matched populations. There is limited evidence to support cost effectiveness of population screening in rheumatoid arthritis and case finding strategies have been proposed as a means to increase cost effectiveness of diagnostic screening for osteoporosis. This study aimed to assess the performance attributes of generic and rheumatoid arthritis specific clinical decision tools for diagnosing osteoporosis in a postmenopausal population with rheumatoid arthritis who attend ambulatory specialist rheumatology clinics. Methods A cross-sectional study of 127 ambulatory post-menopausal women with rheumatoid arthritis was performed. Patients currently receiving or who had previously received bone active therapy were excluded. Eligible women underwent clinical assessment and dual-energy-xray absorptiometry (DXA) bone mineral density assessment. Clinical decision tools, including those specific for rheumatoid arthritis, were compared to seven generic post-menopausal tools to predict osteoporosis (defined as T score < -2.5). Sensitivity, specificity, positive predictive and negative predictive values and area under the curve were assessed. The diagnostic attributes of the clinical decision tools were compared by examination of the area under the receiver-operator-curve. Results One hundred and twenty seven women participated. The median age was 62 (IQR 56–71) years. Median disease duration was 108 (60–168) months. Seventy two (57%) women had no record of a previous DXA examination. Eighty (63%) women had T scores at femoral neck or lumbar spine less than -1. The area under the ROC curve for clinical decision tool prediction of T score <-2.5 varied between 0.63 and 0.76. The rheumatoid arthritis specific decision tools did not perform better than generic tools, however, the National Osteoporosis Foundation score could potentially reduce the number of unnecessary DXA tests by approximately 45% in this population. Conclusion There was limited utility of clinical decision tools for predicting osteoporosis in this patient population. Fracture prediction tools that include risk factors independent of BMD are needed. PMID:18230132

  1. A Sensor-Based Method for Diagnostics of Machine Tool Linear Axes.

    PubMed

    Vogl, Gregory W; Weiss, Brian A; Donmez, M Alkan

    2015-01-01

    A linear axis is a vital subsystem of machine tools, which are vital systems within many manufacturing operations. When installed and operating within a manufacturing facility, a machine tool needs to stay in good condition for parts production. All machine tools degrade during operations, yet knowledge of that degradation is illusive; specifically, accurately detecting degradation of linear axes is a manual and time-consuming process. Thus, manufacturers need automated and efficient methods to diagnose the condition of their machine tool linear axes without disruptions to production. The Prognostics and Health Management for Smart Manufacturing Systems (PHM4SMS) project at the National Institute of Standards and Technology (NIST) developed a sensor-based method to quickly estimate the performance degradation of linear axes. The multi-sensor-based method uses data collected from a 'sensor box' to identify changes in linear and angular errors due to axis degradation; the sensor box contains inclinometers, accelerometers, and rate gyroscopes to capture this data. The sensors are expected to be cost effective with respect to savings in production losses and scrapped parts for a machine tool. Numerical simulations, based on sensor bandwidth and noise specifications, show that changes in straightness and angular errors could be known with acceptable test uncertainty ratios. If a sensor box resides on a machine tool and data is collected periodically, then the degradation of the linear axes can be determined and used for diagnostics and prognostics to help optimize maintenance, production schedules, and ultimately part quality.

  2. A Sensor-Based Method for Diagnostics of Machine Tool Linear Axes

    PubMed Central

    Vogl, Gregory W.; Weiss, Brian A.; Donmez, M. Alkan

    2017-01-01

    A linear axis is a vital subsystem of machine tools, which are vital systems within many manufacturing operations. When installed and operating within a manufacturing facility, a machine tool needs to stay in good condition for parts production. All machine tools degrade during operations, yet knowledge of that degradation is illusive; specifically, accurately detecting degradation of linear axes is a manual and time-consuming process. Thus, manufacturers need automated and efficient methods to diagnose the condition of their machine tool linear axes without disruptions to production. The Prognostics and Health Management for Smart Manufacturing Systems (PHM4SMS) project at the National Institute of Standards and Technology (NIST) developed a sensor-based method to quickly estimate the performance degradation of linear axes. The multi-sensor-based method uses data collected from a ‘sensor box’ to identify changes in linear and angular errors due to axis degradation; the sensor box contains inclinometers, accelerometers, and rate gyroscopes to capture this data. The sensors are expected to be cost effective with respect to savings in production losses and scrapped parts for a machine tool. Numerical simulations, based on sensor bandwidth and noise specifications, show that changes in straightness and angular errors could be known with acceptable test uncertainty ratios. If a sensor box resides on a machine tool and data is collected periodically, then the degradation of the linear axes can be determined and used for diagnostics and prognostics to help optimize maintenance, production schedules, and ultimately part quality. PMID:28691039

  3. The Diagnostic Value of Gastrin-17 Detection in Atrophic Gastritis

    PubMed Central

    Wang, Xu; Ling, Li; Li, Shanshan; Qin, Guiping; Cui, Wei; Li, Xiang; Ni, Hong

    2016-01-01

    Abstract A meta-analysis was performed to assess the diagnostic value of gastrin-17 (G-17) for the early detection of chronic atrophic gastritis (CAG). An extensive literature search was performed, with the aim of selecting publications that reported the accuracy of G-17 in predicting CAG, in the following databases: PubMed, Science Direct, Web of Science, Chinese Biological Medicine, Chinese National Knowledge Infrastructure, Wanfang, and VIP. To assess the diagnostic value of G-17, the following statistics were estimated and described: sensitivity, specificity, diagnostic odds ratios (DOR), summary receiver operating characteristic curves, area under the curve (AUC), and 95% confidence intervals (CIs). Thirteen studies that met the inclusion criteria were included in this meta-analysis, comprising 894 patients and 1950 controls. The pooled sensitivity and specificity of these studies were 0.48 (95% CI: 0.45–0.51) and 0.79 (95% CI: 0.77–0.81), respectively. The DOR was 5.93 (95% CI: 2.93–11.99), and the AUC was 0.82. G-17 may have potential diagnostic value because it has good specificity and a moderate DOR and AUC for CAG. However, more studies are needed to improve the sensitivity of this diagnostic tool in the future. PMID:27149493

  4. Ontology and medical diagnosis.

    PubMed

    Bertaud-Gounot, Valérie; Duvauferrier, Régis; Burgun, Anita

    2012-03-01

    Ontology and associated generic tools are appropriate for knowledge modeling and reasoning, but most of the time, disease definitions in existing description logic (DL) ontology are not sufficient to classify patient's characteristics under a particular disease because they do not formalize operational definitions of diseases (association of signs and symptoms=diagnostic criteria). The main objective of this study is to propose an ontological representation which takes into account the diagnostic criteria on which specific patient conditions may be classified under a specific disease. This method needs as a prerequisite a clear list of necessary and sufficient diagnostic criteria as defined for lots of diseases by learned societies. It does not include probability/uncertainty which Web Ontology Language (OWL 2.0) cannot handle. We illustrate it with spondyloarthritis (SpA). Ontology has been designed in Protégé 4.1 OWL-DL2.0. Several kinds of criteria were formalized: (1) mandatory criteria, (2) picking two criteria among several diagnostic criteria, (3) numeric criteria. Thirty real patient cases were successfully classified with the reasoner. This study shows that it is possible to represent operational definitions of diseases with OWL and successfully classify real patient cases. Representing diagnostic criteria as descriptive knowledge (instead of rules in Semantic Web Rule Language or Prolog) allows us to take advantage of tools already available for OWL. While we focused on Assessment of SpondyloArthritis international Society SpA criteria, we believe that many of the representation issues addressed here are relevant to using OWL-DL for operational definition of other diseases in ontology.

  5. An electronic screen for triaging adolescent substance use by risk levels.

    PubMed

    Levy, Sharon; Weiss, Roger; Sherritt, Lon; Ziemnik, Rosemary; Spalding, Allegra; Van Hook, Shari; Shrier, Lydia A

    2014-09-01

    Screening adolescents for substance use and intervening immediately can reduce the burden of addiction and substance-related morbidity. Several screening tools have been developed to identify problem substance use for adolescents, but none have been calibrated to triage adolescents into clinically relevant risk categories to guide interventions. To describe the psychometric properties of an electronic screen and brief assessment tool that triages adolescents into 4 actionable categories regarding their experience with nontobacco substance use. Adolescent patients (age range, 12-17 years) arriving for routine medical care at 2 outpatient primary care centers and 1 outpatient center for substance use treatment at a pediatric hospital completed an electronic screening tool from June 1, 2012, through March 31, 2013, that consisted of a question on the frequency of using 8 types of drugs in the past year (Screening to Brief Intervention). Additional questions assessed severity of any past-year substance use. Patients completed a structured diagnostic interview (Composite International Diagnostic Interview-Substance Abuse Module), yielding Diagnostic and Statistical Manual of Mental Disorders (Fifth Edition) substance use diagnoses. For the entire screen and the Screening to Brief Intervention, sensitivity and specificity for identifying nontobacco substance use, substance use disorders, severe substance use disorders, and tobacco dependence were calculated using the Composite International Diagnostic Interview-Substance Abuse Module as the criterion standard. Of 340 patients invited to participate, 216 (63.5%) enrolled in the study. Sensitivity and specificity were 100% and 84% (95% CI, 76%-89%) for identifying nontobacco substance use, 90% (95% CI, 77%-96%) and 94% (95% CI, 89%-96%) for substance use disorders, 100% and 94% (95% CI, 90%-96%) for severe substance use disorders, and 75% (95% CI, 52%-89%) and 98% (95% CI, 95%-100%) for nicotine dependence. No significant differences were found in sensitivity or specificity between the full tool and the Screening to Brief Intervention. A single screening question assessing past-year frequency use for 8 commonly misused categories of substances appears to be a valid method for discriminating among clinically relevant risk categories of adolescent substance use.

  6. An Electronic Screen for Triaging Adolescent Substance Use by Risk Levels

    PubMed Central

    Levy, Sharon; Weiss, Roger; Sherritt, Lon; Ziemnik, Rosemary; Spalding, Allegra; Van Hook, Shari; Shrier, Lydia A.

    2014-01-01

    IMPORTANCE Screening adolescents for substance use and intervening immediately can reduce the burden of addiction and substance-related morbidity. Several screening tools have been developed to identify problem substance use for adolescents, but none have been calibrated to triage adolescents into clinically relevant risk categories to guide interventions. OBJECTIVE To describe the psychometric properties of an electronic screen and brief assessment tool that triages adolescents into 4 actionable categories regarding their experience with nontobacco substance use. DESIGN, SETTING, AND PARTICIPANTS Adolescent patients (age range, 12–17 years) arriving for routine medical care at 2 outpatient primary care centers and 1 outpatient center for substance use treatment at a pediatric hospital completed an electronic screening tool from June 1, 2012, through March 31, 2013, that consisted of a question on the frequency of using 8 types of drugs in the past year (Screening to Brief Intervention). Additional questions assessed severity of any past-year substance use. Patients completed a structured diagnostic interview (Composite International Diagnostic Interview–Substance Abuse Module), yielding Diagnostic and Statistical Manual of Mental Disorders (Fifth Edition) substance use diagnoses. MAIN OUTCOMES AND MEASURES For the entire screen and the Screening to Brief Intervention, sensitivity and specificity for identifying nontobacco substance use, substance use disorders, severe substance use disorders, and tobacco dependence were calculated using the Composite International Diagnostic Interview–Substance Abuse Module as the criterion standard. RESULTS Of 340 patients invited to participate, 216 (63.5%) enrolled in the study. Sensitivity and specificity were 100% and 84%(95%CI, 76%–89%) for identifying nontobacco substance use, 90% (95%CI, 77%–96%) and 94%(95%CI, 89%–96%) for substance use disorders, 100% and 94%(95%CI, 90%–96%) for severe substance use disorders, and 75% (95%CI, 52%–89%) and 98%(95%CI, 95%–100%) for nicotine dependence. No significant differences were found in sensitivity or specificity between the full tool and the Screening to Brief Intervention. CONCLUSIONS AND RELEVANCE A single screening question assessing past-year frequency use for 8 commonly misused categories of substances appears to be a valid method for discriminating among clinically relevant risk categories of adolescent substance use. PMID:25070067

  7. An Object-Based Approach to Evaluation of Climate Variability Projections and Predictions

    NASA Astrophysics Data System (ADS)

    Ammann, C. M.; Brown, B.; Kalb, C. P.; Bullock, R.

    2017-12-01

    Evaluations of the performance of earth system model predictions and projections are of critical importance to enhance usefulness of these products. Such evaluations need to address specific concerns depending on the system and decisions of interest; hence, evaluation tools must be tailored to inform about specific issues. Traditional approaches that summarize grid-based comparisons of analyses and models, or between current and future climate, often do not reveal important information about the models' performance (e.g., spatial or temporal displacements; the reason behind a poor score) and are unable to accommodate these specific information needs. For example, summary statistics such as the correlation coefficient or the mean-squared error provide minimal information to developers, users, and decision makers regarding what is "right" and "wrong" with a model. New spatial and temporal-spatial object-based tools from the field of weather forecast verification (where comparisons typically focus on much finer temporal and spatial scales) have been adapted to more completely answer some of the important earth system model evaluation questions. In particular, the Method for Object-based Diagnostic Evaluation (MODE) tool and its temporal (three-dimensional) extension (MODE-TD) have been adapted for these evaluations. More specifically, these tools can be used to address spatial and temporal displacements in projections of El Nino-related precipitation and/or temperature anomalies, ITCZ-associated precipitation areas, atmospheric rivers, seasonal sea-ice extent, and other features of interest. Examples of several applications of these tools in a climate context will be presented, using output of the CESM large ensemble. In general, these tools provide diagnostic information about model performance - accounting for spatial, temporal, and intensity differences - that cannot be achieved using traditional (scalar) model comparison approaches. Thus, they can provide more meaningful information that can be used in decision-making and planning. Future extensions and applications of these tools in a climate context will be considered.

  8. Replication and Comparison of the Newly Proposed ADOS-2, Module 4 Algorithm in ASD Without ID: A Multi-site Study.

    PubMed

    Pugliese, Cara E; Kenworthy, Lauren; Bal, Vanessa Hus; Wallace, Gregory L; Yerys, Benjamin E; Maddox, Brenna B; White, Susan W; Popal, Haroon; Armour, Anna Chelsea; Miller, Judith; Herrington, John D; Schultz, Robert T; Martin, Alex; Anthony, Laura Gutermuth

    2015-12-01

    Recent updates have been proposed to the Autism Diagnostic Observation Schedule-2 Module 4 diagnostic algorithm. This new algorithm, however, has not yet been validated in an independent sample without intellectual disability (ID). This multi-site study compared the original and revised algorithms in individuals with ASD without ID. The revised algorithm demonstrated increased sensitivity, but lower specificity in the overall sample. Estimates were highest for females, individuals with a verbal IQ below 85 or above 115, and ages 16 and older. Best practice diagnostic procedures should include the Module 4 in conjunction with other assessment tools. Balancing needs for sensitivity and specificity depending on the purpose of assessment (e.g., clinical vs. research) and demographic characteristics mentioned above will enhance its utility.

  9. Use of bacteriophage cell wall-binding proteins for rapid diagnostics of Listeria.

    PubMed

    Schmelcher, Mathias; Loessner, Martin J

    2014-01-01

    Diagnostic protocols for food-borne bacterial pathogens such as Listeria need to be sensitive, specific, rapid, and inexpensive. Conventional culture methods are hampered by lengthy enrichment and incubation steps. Bacteriophage-derived high-affinity binding molecules (cell wall-binding domains, CBDs) specific for Listeria cells have recently been introduced as tools for detection and differentiation of this pathogen in foods. When coupled with magnetic separation, these proteins offer advantages in sensitivity and speed compared to the standard diagnostic methods. Furthermore, fusion of CBDs to differently colored fluorescent reporter proteins enables differentiation of Listeria strains in mixed cultures. This chapter provides protocols for detection of Listeria in food by CBD-based magnetic separation and subsequent multiplexed identification of strains of different serotypes with reporter-CBD fusion proteins.

  10. Loop mediated isothermal amplification: An innovative gene amplification technique for animal diseases.

    PubMed

    Sahoo, Pravas Ranjan; Sethy, Kamadev; Mohapatra, Swagat; Panda, Debasis

    2016-05-01

    India being a developing country mainly depends on livestock sector for its economy. However, nowadays, there is emergence and reemergence of more transboundary animal diseases. The existing diagnostic techniques are not so quick and with less specificity. To reduce the economy loss, there should be a development of rapid, reliable, robust diagnostic technique, which can work with high degree of sensitivity and specificity. Loop mediated isothermal amplification assay is a rapid gene amplification technique that amplifies nucleic acid under an isothermal condition with a set of designed primers spanning eight distinct sequences of the target. This assay can be used as an emerging powerful, innovative gene amplification diagnostic tool against various pathogens of livestock diseases. This review is to highlight the basic concept and methodology of this assay in livestock disease.

  11. Methodological quality of diagnostic accuracy studies on non-invasive coronary CT angiography: influence of QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) items on sensitivity and specificity.

    PubMed

    Schueler, Sabine; Walther, Stefan; Schuetz, Georg M; Schlattmann, Peter; Dewey, Marc

    2013-06-01

    To evaluate the methodological quality of diagnostic accuracy studies on coronary computed tomography (CT) angiography using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) tool. Each QUADAS item was individually defined to adapt it to the special requirements of studies on coronary CT angiography. Two independent investigators analysed 118 studies using 12 QUADAS items. Meta-regression and pooled analyses were performed to identify possible effects of methodological quality items on estimates of diagnostic accuracy. The overall methodological quality of coronary CT studies was merely moderate. They fulfilled a median of 7.5 out of 12 items. Only 9 of the 118 studies fulfilled more than 75 % of possible QUADAS items. One QUADAS item ("Uninterpretable Results") showed a significant influence (P = 0.02) on estimates of diagnostic accuracy with "no fulfilment" increasing specificity from 86 to 90 %. Furthermore, pooled analysis revealed that each QUADAS item that is not fulfilled has the potential to change estimates of diagnostic accuracy. The methodological quality of studies investigating the diagnostic accuracy of non-invasive coronary CT is only moderate and was found to affect the sensitivity and specificity. An improvement is highly desirable because good methodology is crucial for adequately assessing imaging technologies. • Good methodological quality is a basic requirement in diagnostic accuracy studies. • Most coronary CT angiography studies have only been of moderate design quality. • Weak methodological quality will affect the sensitivity and specificity. • No improvement in methodological quality was observed over time. • Authors should consider the QUADAS checklist when undertaking accuracy studies.

  12. Isoenzymes.

    ERIC Educational Resources Information Center

    Daugherty, N. A.

    1979-01-01

    The uses of isoenzyme assays are reviewed as they relate to solutions of practical problems. Emphasizes their use of diagnostic tools in medicine, specifically in cardiac profiling. Suggests that principles of isoenzyme assays readily demonstrate molecular structure, acid-base equilibria, kinetics, and electrochemistry to general chemistry…

  13. SITE-SPECIFIC DIAGNOSTIC TOOLS

    EPA Science Inventory

    US EPA's Office of Water is proposing Combined Assessment and Listing Methods (CALM) to
    meet reporting requirements under both Sections 305b and 303d for chemical and nonchemical
    stressors in the nation's waterbodies. Current Environmental Monitoring and Assessment
    Prog...

  14. MOLECULAR DIAGNOSTICS - ANOTHER PIECE IN THE ENVIRONMENTAL PUZZLE

    EPA Science Inventory

    Molecular biology offers sensitive and expedient tools for the detection of exposure to environmental stressors. Molecular approaches provide the means for detection of the "first cellular event(s)" in response to environmental changes-specifically, immediate changes in gene expr...

  15. A selective nanosensor device for exhaled breath analysis.

    PubMed

    Gouma, P; Prasad, A; Stanacevic, S

    2011-09-01

    This paper describes a novel concept of a three-nanosensor array microsystem that may potentially serve as a coarse diagnostic tool handheld breath analyzer to provide a first detection device. The specification and performance of a simple metal oxide nanosensor operating between three distinct temperatures are discussed, focusing on the need for a noninvasive blood cholesterol monitor. Interfacing the sensor array to an integrated circuit for electrical readout and temperature control provides a complete microsystem capable of capturing a single exhaled breath and analyzing it with respect to the relative content of isoprene, carbon dioxide and ammonia gas. This inexpensive sensor technology may be used as a personalized medical diagnostics tool in the near future.

  16. A diagnostic interface for the ICOsahedral Non-hydrostatic (ICON) modelling framework based on the Modular Earth Submodel System (MESSy v2.50)

    NASA Astrophysics Data System (ADS)

    Kern, Bastian; Jöckel, Patrick

    2016-10-01

    Numerical climate and weather models have advanced to finer scales, accompanied by large amounts of output data. The model systems hit the input and output (I/O) bottleneck of modern high-performance computing (HPC) systems. We aim to apply diagnostic methods online during the model simulation instead of applying them as a post-processing step to written output data, to reduce the amount of I/O. To include diagnostic tools into the model system, we implemented a standardised, easy-to-use interface based on the Modular Earth Submodel System (MESSy) into the ICOsahedral Non-hydrostatic (ICON) modelling framework. The integration of the diagnostic interface into the model system is briefly described. Furthermore, we present a prototype implementation of an advanced online diagnostic tool for the aggregation of model data onto a user-defined regular coarse grid. This diagnostic tool will be used to reduce the amount of model output in future simulations. Performance tests of the interface and of two different diagnostic tools show, that the interface itself introduces no overhead in form of additional runtime to the model system. The diagnostic tools, however, have significant impact on the model system's runtime. This overhead strongly depends on the characteristics and implementation of the diagnostic tool. A diagnostic tool with high inter-process communication introduces large overhead, whereas the additional runtime of a diagnostic tool without inter-process communication is low. We briefly describe our efforts to reduce the additional runtime from the diagnostic tools, and present a brief analysis of memory consumption. Future work will focus on optimisation of the memory footprint and the I/O operations of the diagnostic interface.

  17. A systematic review of the sensitivity and specificity of the toe-brachial index for detecting peripheral artery disease.

    PubMed

    Tehan, Peta Ellen; Santos, Derek; Chuter, Vivienne Helaine

    2016-08-01

    The toe-brachial index (TBI) is used as an adjunct to the ankle-brachial index (ABI) for non-invasive lower limb vascular screening. With increasing evidence suggesting limitations of the ABI for diagnosis of vascular complications, particularly in specific populations including diabetes cohorts, the TBI is being used more widely. The aim of this review was to determine the sensitivity and specificity of the TBI for detecting peripheral artery disease (PAD) in populations at risk of this disease. A database search was conducted to identify current work relating to the sensitivity and specificity of toe-brachial indices up to July 2015. Only studies using valid diagnostic imaging as a reference standard were included. The QUADAS-2 tool was used to critically appraise included articles. Seven studies met the inclusion criteria. Sensitivity of the TBI for PAD was reported in all seven studies and ranged from 45% to 100%; specificity was reported by five studies only and ranged from 16% to 100%. In conclusion, this review suggests that the TBI has variable diagnostic accuracy for the presence of PAD in specific populations at risk of developing the disease. There was a notable lack of large-scale diagnostic accuracy studies determining the diagnostic accuracy of the TBI in detecting PAD in different at-risk cohorts. However, standardised normal values need to be established for the TBI to conclusively determine the diagnostic accuracy of this test. © The Author(s) 2016.

  18. Component-resolved diagnostics in vernal conjunctivitis.

    PubMed

    Armentia, Alicia; Sanchís, Eugenia; Montero, Javier A

    2016-10-01

    Conventional diagnostic tests in allergy are insufficient to clarify the cause of vernal conjunctivitis. Component-resolved diagnostic (CRD) by microarray allergen assay may be useful in detecting allergens that might be involved in the inflammatory process. In a recent trial in patients suffered from eosinophilic esophagitis, after 2 years of the CRD-guided exclusion diet and specific immunotherapy, significant clinical improvement was observed, and 68% of patients were discharged (cure based on negative biopsy, no symptoms, and no medication intake). Our new objective was to evaluate IgE-mediated hypersensitivity by CRD in tears and serum from patients with vernal conjunctivitis and treat patients with identified triggering allergens by specific immunotherapy. Twenty-five patients with vernal conjunctivitis were evaluated. The identified triggering allergens were n Lol p 1 (11 cases), n Cyn d 1 (eight cases), group 4 and 6 grasses (six cases) and group 5 of grasses (five cases). Prick test and pollen IgE were positive in one case. Clinical improvement was observed in 13/25 vernal conjunctivitis patients after 1-year specific immunotherapy. CRD seems to be a more sensitive diagnostic tool compared with prick test and IgE detection. Specific CRD-led immunotherapy may achieve clinical improvements in vernal conjunctivitis patients.

  19. [Gene expression analyses of kidney biopsies: the European renal cDNA bank--Kröner-Fresenius biopsy bank].

    PubMed

    Cohen, C D; Kretzler, M

    2009-03-01

    Histological analysis of kidney biopsies is an essential part of our current diagnostic workup of patients with renal disease. Besides the already established diagnostic tools, new methods allow extensive analysis of the sample tissue's gene expression. Using results from a European multicenter study on gene expression analysis of renal biopsies, in this review we demonstrate that this novel approach not only expands the scope of so-called basic research but also might supplement future biopsy diagnostics. The goals are improved diagnosis and more specific therapy choice and prognosis estimates.

  20. Confocal microscopy patterns in nonmelanoma skin cancer and clinical applications.

    PubMed

    González, S; Sánchez, V; González-Rodríguez, A; Parrado, C; Ullrich, M

    2014-06-01

    Reflectance confocal microscopy is currently the most promising noninvasive diagnostic tool for studying cutaneous structures between the stratum corneum and the superficial reticular dermis. This tool gives real-time images parallel to the skin surface; the microscopic resolution is similar to that of conventional histology. Numerous studies have identified the main confocal features of various inflammatory skin diseases and tumors, demonstrating the good correlation of these features with certain dermatoscopic patterns and histologic findings. Confocal patterns and diagnostic algorithms have been shown to have high sensitivity and specificity in melanoma and nonmelanoma skin cancer. Possible present and future applications of this noninvasive technology are wide ranging and reach beyond its use in noninvasive diagnosis. This tool can also be used, for example, to evaluate dynamic skin processes that occur after UV exposure or to assess tumor response to noninvasive treatments such as photodynamic therapy. We explain the characteristic confocal features found in the main nonmelanoma skin tumors and discuss possible applications for this novel diagnostic technique in routine dermatology practice. Copyright © 2012 Elsevier España, S.L. and AEDV. All rights reserved.

  1. MicroRNAs in osteosarcoma: diagnostic and therapeutic aspects.

    PubMed

    Miao, Jinglei; Wu, Song; Peng, Zhi; Tania, Mousumi; Zhang, Chaoyue

    2013-08-01

    MicroRNAs (miRNAs) are small RNA molecules, which can interfere with the expression of several genes and act as gene regulator. miRNAs have been proved as a successful diagnostic and therapeutic tool in several cancers. In this review, the differential expression of miRNAs in osteosarcoma and their possibility to be used as diagnostic and therapeutic tools have been discussed. Osteosarcoma is the most common primary bone tumor that mainly affects children and adolescents. The current treatment of osteosarcoma remains difficult, and osteosarcoma causes many deaths because of its complex pathogenesis and resistance to conventional treatments. Several studies demonstrated that the differential expression patterns of miRNAs are a promising tool for the diagnosis and treatment of osteosarcoma. Although some aspect of the mechanism of action of miRNAs in controlling osteosarcoma has been identified (e.g., targeting the Notch signaling pathway), it is far beyond to the clear understanding of miRNA targets in osteosarcoma. Identification of the specific target of miRNAs may aid molecular targets for drug development and future relief of osteosarcoma.

  2. ADC as a useful diagnostic tool for differentiating benign and malignant vertebral bone marrow lesions and compression fractures: a systematic review and meta-analysis.

    PubMed

    Suh, Chong Hyun; Yun, Seong Jong; Jin, Wook; Lee, Sun Hwa; Park, So Young; Ryu, Chang-Woo

    2018-07-01

    To assess the sensitivity and specificity of quantitative assessment of the apparent diffusion coefficient (ADC) for differentiating benign and malignant vertebral bone marrow lesions (BMLs) and compression fractures (CFs) METHODS: An electronic literature search of MEDLINE and EMBASE was conducted. Bivariate modelling and hierarchical summary receiver operating characteristic modelling were performed to evaluate the diagnostic performance of ADC for differentiating vertebral BMLs. Subgroup analysis was performed for differentiating benign and malignant vertebral CFs. Meta-regression analyses according to subject, study and diffusion-weighted imaging (DWI) characteristics were performed. Twelve eligible studies (748 lesions, 661 patients) were included. The ADC exhibited a pooled sensitivity of 0.89 (95% confidence interval [CI] 0.80-0.94) and a pooled specificity of 0.87 (95% CI 0.78-0.93) for differentiating benign and malignant vertebral BMLs. In addition, the pooled sensitivity and specificity for differentiating benign and malignant CFs were 0.92 (95% CI 0.82-0.97) and 0.91 (95% CI 0.87-0.94), respectively. In the meta-regression analysis, the DWI slice thickness was a significant factor affecting heterogeneity (p < 0.01); thinner slice thickness (< 5 mm) showed higher specificity (95%) than thicker slice thickness (81%). Quantitative assessment of ADC is a useful diagnostic tool for differentiating benign and malignant vertebral BMLs and CFs. • Quantitative assessment of ADC is useful in differentiating vertebral BMLs. • Quantitative ADC assessment for BMLs had sensitivity of 89%, specificity of 87%. • Quantitative ADC assessment for CFs had sensitivity of 92%, specificity of 91%. • The specificity is highest (95%) with thinner (< 5 mm) DWI slice thickness.

  3. Patient phenotypes in fibromyalgia comorbid with systemic sclerosis or rheumatoid arthritis: influence of diagnostic and screening tests. Screening with the FiRST questionnaire, diagnosis with the ACR 1990 and revised ACR 2010 criteria.

    PubMed

    Perrot, Serge; Peixoto, Mariana; Dieudé, Philippe; Hachulla, Eric; Avouac, Jerome; Ottaviani, Sebastien; Allanore, Yannick

    2017-01-01

    Fibromyalgia (FM) may occur with rheumatoid arthritis (RA) and systemic sclerosis (SSc), and debate remains about its diagnosis. We aimed to use three FM tools (a screening tool (FiRST), diagnostic criteria (ACR 1990 and revised 2010), to compare FM prevalence between RA and SSc patients, to describe the phenotypes of patients with comorbid FM, and to analyze links between FM and secondary Sjögren's syndrome (SS). Consecutive adult patients with confirmed RA or SSc from four university hospitals were tested with the three FM tools. FiRST detected FM in 22.6% of the 172 RA patients, with confirmation in 22.1% (ACR1990) and 19.1% (ACR2010). ACR1990FM+ RA patients had more diffuse pain, whereas ACR2010FM+ RA patients had higher BMI and pain intensity, more diffuse pain, active disease, disability, and associated SS. FiRST detected FM in 27.8% of the 122 SSc patients, with confirmation in 30.3% (ACR1990) and 23.7% (ACR2010). ACR1990FM+ SSc patients had greater disability and pain intensity, and more diffuse pain, whereas ACR2010FM+ SSc patients had higher BMI, pain intensity, more disability and diffuse pain, and associated SS. Correlations between FM diagnostic and screening tool results were modest in both conditions. Secondary SS was associated with comorbid FM. The prevalence of FM is high in SSc and RA, whatever the FM diagnostic tool used. Secondary SS is associated with FM in both RA and SSc. The revised ACR 2010 FM criteria and FiRST screening tool reveal specific phenotypes potentially useful for improving disease management.

  4. Diagnostic Accuracy of Natriuretic Peptides for Heart Failure in Patients with Pleural Effusion: A Systematic Review and Updated Meta-Analysis

    PubMed Central

    Cheng, Juan-Juan; Zhao, Shi-Di; Gao, Ming-Zhu; Huang, Hong-Yu; Gu, Bing; Ma, Ping; Chen, Yan; Wang, Jun-Hong; Yang, Cheng-Jian; Yan, Zi-He

    2015-01-01

    Background Previous studies have reported that natriuretic peptides in the blood and pleural fluid (PF) are effective diagnostic markers for heart failure (HF). These natriuretic peptides include N-terminal pro-brain natriuretic peptide (NT-proBNP), brain natriuretic peptide (BNP), and midregion pro-atrial natriuretic peptide (MR-proANP). This systematic review and meta-analysis evaluates the diagnostic accuracy of blood and PF natriuretic peptides for HF in patients with pleural effusion. Methods PubMed and EMBASE databases were searched to identify articles published in English that investigated the diagnostic accuracy of BNP, NT-proBNP, and MR-proANP for HF. The last search was performed on 9 October 2014. The quality of the eligible studies was assessed using the revised Quality Assessment of Diagnostic Accuracy Studies tool. The diagnostic performance characteristics (sensitivity, specificity, and other measures of accuracy) were pooled and examined using a bivariate model. Results In total, 14 studies were included in the meta-analysis, including 12 studies reporting the diagnostic accuracy of PF NT-proBNP and 4 studies evaluating blood NT-proBNP. The summary estimates of PF NT-proBNP for HF had a diagnostic sensitivity of 0.94 (95% confidence interval [CI]: 0.90–0.96), specificity of 0.91 (95% CI: 0.86–0.95), positive likelihood ratio of 10.9 (95% CI: 6.4–18.6), negative likelihood ratio of 0.07 (95% CI: 0.04–0.12), and diagnostic odds ratio of 157 (95% CI: 57–430). The overall sensitivity of blood NT-proBNP for diagnosis of HF was 0.92 (95% CI: 0.86–0.95), with a specificity of 0.88 (95% CI: 0.77–0.94), positive likelihood ratio of 7.8 (95% CI: 3.7–16.3), negative likelihood ratio of 0.10 (95% CI: 0.06–0.16), and diagnostic odds ratio of 81 (95% CI: 27–241). The diagnostic accuracy of PF MR-proANP and blood and PF BNP was not analyzed due to the small number of related studies. Conclusions BNP, NT-proBNP, and MR-proANP, either in blood or PF, are effective tools for diagnosis of HF. Additional studies are needed to rigorously evaluate the diagnostic accuracy of PF and blood MR-proANP and BNP for the diagnosis of HF. PMID:26244664

  5. Indications requiring preoperative magnetic resonance imaging before knee arthroscopy.

    PubMed

    Roßbach, Björn Peter; Pietschmann, Matthias Frank; Gülecyüz, Mehmet Fatih; Niethammer, Thomas Richard; Ficklscherer, Andreas; Wild, Stefan; Jansson, Volkmar; Müller, Peter Ernst

    2014-12-22

    Knee arthroscopy knee is gold standard in diagnosis and simultaneous treatment of knee disorders. But most patients undergo magnetic resonance imaging (MRI) before arthroscopy, although MRI results are not always consistent with arthroscopic findings. This raises the question in which suspected diagnoses MRI really has influence on diagnosis and consecutive surgical therapy. Preoperative MRI of 330 patients with knee disorders were compared with arthroscopic findings. The MRI were performed by 23 radiologists without specialization in musculoskeletal diagnostics. Specificity, sensitivity, negative/positive predictive value and accuracy of MRI were calculated in comparison to arthroscopic findings. We found sensitivity/specificity of 58%/93% for anterior horn, 94%/46% for posterior horn of medial meniscus and 71%/81% for anterior and 62%/82% for posterior horn of lateral meniscus. Related to anterior cruciate ligament injuries we showed sensitivity/specificity of 82%/91% for grade 0 + I and 72%/96% for grade II + III. For Cartilage damage sensitivity/specificity of 98%/7% for grade I-, 89%/29% for grade II-, 96%/38% for grade III- and 96%/69% for grade IV-lesions were revealed. The MRI should not be used as routine diagnostic tool for knee pain. No relevant information for meniscal lesions and anterior cruciate ligament ruptures has been gained with MRI from non-specialized outside imaging centres. The MRI should not be used as routine diagnostic tool for knee pain. No relevant information for meniscal lesions and anterior cruciate ligament ruptures has been gained with MRI from non-specialized outside imaging centres.

  6. The Role of Computed Tomography in Blunt Abdominal Trauma.

    PubMed

    Karki, O B

    2015-01-01

    Blunt injury trauma is regularly encountered in the emergency department. Diagnostic tools that help in optimum management of blunt abdominal trauma include; Focussed Assessment Sonography for Trauma scan, Diagnostic peritoneal lavage and Computed Tomography scan. The aim of this study is to determine the validity of CT scan as an accurate diagnostic tool and its role in management of patients with blunt abdominal trauma. A prospective analysis of 80 patients of blunt abdomen trauma who were admitted in Manipal Teaching Hospital, Pokhara, Nepal within a span of 15 months was done. Demographic data, mechanism of trauma, management and outcomes were studied. Organ injuries were graded using the Organ Injury Scale guidelines. Most of the patients in our study were in the age group of 21-40 years with an M: F ratio of 2.3:1. Road traffic accident (47.5%) was the most common mechanism of injury. Spleen (27.5%) was the commonest organ injured. CT scan was superior to FAST scan and had sensitivity of 97.3% specificity 75% positive predictive value 98.6%. FAST scan had sensitivity of 78.9%, specificity 50%, positive predictive value 96% with p- value of 0.0034. 81% of patients were conservatively managed. In conjunction with close clinical monitoring, CT scan is reliable in the evaluation and management of blunt abdominal trauma patients. Our study also shows CT as a superior diagnostic modality compared to FAST scan.

  7. Breast-specific gamma camera imaging with 99mTc-MIBI has better diagnostic performance than magnetic resonance imaging in breast cancer patients: A meta-analysis.

    PubMed

    Zhang, Aimi; Li, Panli; Liu, Qiufang; Song, Shaoli

    2017-01-01

    This study aimed to evaluate the diagnostic role of breast-specific gamma camera imaging (BSGI) with technetium-99m-methoxy isobutyl isonitrile ( 99m Tc-MIBI) and magnetic resonance imaging (MRI) in patients with breast cancer through a meta-analysis. Three reviewers searched articles published in medical journals before June 2016 in MEDLINE, EMBASE and Springer Databases; the references listed in original articles were also retrieved. We used the quality assessment of diagnostic accuracy studies (QUADAS) tool to assess the quality of the included studies. Heterogeneity, pooled sensitivity and specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio (DOR) and summary receiver operating characteristic (SROC) curves were calculated by Meta-DiSc software to estimate the diagnostic performance of BSGI and MRI. Ten studies with 517 patients were included after meeting the inclusion criteria. We did a subgroup analysis of the same data type. The pooled sensitivities of BSGI and MRI were: 0.84 (95% CI, 0.79-0.88) and 0.89 (95% CI, 0.84-0.92) respectively, and the pooled specificities of BSGI and MRI were: 0.82 (95% CI, 0.74-0.88) and 0.39 (95% CI, 0.30-0.49) respectively. The areas under the SROC curve of BSGI and MRI were 0.93 and 0.72 respectively. The results of our meta-analysis indicated that compared with MRI, BSGI has similar sensitivity, higher specificity, better diagnostic performance, and can be widely used in clinical practice.

  8. Screening tests for distal symmetrical polyneuropathy in Latin American patients with type 2 diabetes mellitus.

    PubMed

    Gómez-Banoy, Nicolás; Cuevas, Virginia; Soler, Fernando; Pineda, Maria Fernanda; Mockus, Ismena

    2017-01-01

    This cross sectional study intended to evaluate two bedside tests (Neuropad and VibraTip) as screening tools for distal symmetrical polyneuropathy (DSPN) in Latin American patients with type 2 diabetes mellitus (T2D). Ninety-three Colombian patients diagnosed with T2D were recruited. Anthropometric variables, glycemic control parameters, lipid profile and renal function were assessed for each patient. DSPN was defined by a Michigan Neuropathy Screening Instrument (MNSI) clinical score greater than 2. Both Neuropad and Vibratip tests were applied to each patient. Contingency analyses were performed to evaluate the diagnostic power of both tools. The prevalence of DSPN determined clinically by MNSI was 25.8%. DSPN in these patients was associated with age, worsening renal function, and insulin treatment. The sensitivity and specificity of the Neuropad test for DSPN was 66.6% and 63% respectively. Its negative predictive value (NPV) was 84.6%. The VibraTip test exhibited a sensitivity of 54.1% and specificity of 91.3%, with a NPV of 85.1%. Neuropad and VibraTip are reliable screening tools for DSPN in Latin American population. VibraTip presents a considerable diagnostic power for DSPN in this population. Further studies regarding the cost-effectiveness of these tools in clinical practice are needed.

  9. Sensitivity and Specificity of Long Wave Infrared Imaging for Attention-Deficit/Hyperactivity Disorder

    ERIC Educational Resources Information Center

    Coben, Robert; Myers, Thomas E.

    2009-01-01

    Objective: This study was the first to investigate the efficacy of long wave infrared (LWIR) imaging as a diagnostic tool for ADHD. Method: with ADHD and a high level of specificity (94%) in discriminating those with ADHD from those with other diagnoses. The overall classification rate was 73.16%. This was indicative of a high level of…

  10. Bias-corrected diagnostic performance of the naked-eye single-tube red-cell osmotic fragility test (NESTROFT): an effective screening tool for beta-thalassemia.

    PubMed

    Mamtani, Manju; Jawahirani, Anil; Das, Kishor; Rughwani, Vinky; Kulkarni, Hemant

    2006-08-01

    It is being increasingly recognized that a majority of the countries in the thalassemia-belt need a cost-effective screening program as the first step towards control of thalassemia. Although the naked eye single tube red cell osmotic fragility test (NESTROFT) has been considered to be a very effective screening tool for beta-thalassemia trait, assessment of its diagnostic performance has been affected with the reference test- and verification-bias. Here, we set out to provide estimates of sensitivity and specificity of NESTROFT corrected for these potential biases. We conducted a cross-sectional diagnostic test evaluation study using data from 1563 subjects from Central India with a high prevalence of beta-thalassemia. We used latent class modelling after ensuring its validity to account for the reference test bias and global sensitivity analysis to control the verification bias. We also compared the results of latent class modelling with those of five discriminant indexes. We observed that across a range of cut-offs for the mean corpuscular volume (MCV) and the hemoglobin A2 (HbA2) concentration the average sensitivity and specificity of NESTROFT obtained from latent class modelling was 99.8 and 83.7%, respectively. These estimates were comparable to those characterizing the diagnostic performance of HbA2, which is considered by many as the reference test to detect beta-thalassemia. After correction for the verification bias these estimates were 93.4 and 97.2%, respectively. Combined with the inexpensive and quick disposition of NESTROFT, these results strongly support its candidature as a screening tool-especially in the resource-poor and high-prevalence settings.

  11. Adding Four- Dimensional Data Assimilation (aka grid ...

    EPA Pesticide Factsheets

    Adding four-dimensional data assimilation (a.k.a. grid nudging) to MPAS.The U.S. Environmental Protection Agency is investigating the use of MPAS as the meteorological driver for its next-generation air quality model. To function as such, MPAS needs to operate in a diagnostic mode in much the same manner as the current meteorological driver, the Weather Research and Forecasting (WRF) model. The WRF operates in diagnostic mode using Four-Dimensional Data Assimilation, also known as "grid nudging". MPAS version 4.0 has been modified with the addition of an FDDA routine to the standard physics drivers to nudge the state variables for wind, temperature and water vapor towards MPAS initialization fields defined at 6-hour intervals from GFS-derived data. The results to be shown demonstrate the ability to constrain MPAS simulations to known historical conditions and thus provide the U.S. EPA with a practical meteorological driver for global-scale air quality simulations. The National Exposure Research Laboratory (NERL) Computational Exposure Division (CED) develops and evaluates data, decision-support tools, and models to be applied to media-specific or receptor-specific problem areas. CED uses modeling-based approaches to characterize exposures, evaluate fate and transport, and support environmental diagnostics/forensics with input from multiple data sources. It also develops media- and receptor-specific models, process models, and decision support tools for use bo

  12. The clinical utility and diagnostic performance of magnetic resonance imaging for identification of early and advanced knee osteoarthritis: a systematic review.

    PubMed

    Quatman, Carmen E; Hettrich, Carolyn M; Schmitt, Laura C; Spindler, Kurt P

    2011-07-01

    Current diagnostic strategies for detection of structural articular cartilage abnormalities, the earliest structural signs of osteoarthritis, often do not capture the condition until it is too far advanced for the most potential benefit of noninvasive interventions. To systematically review the literature relative to the following questions: (1) Is magnetic resonance imaging (MRI) a valid, sensitive, specific, accurate, and reliable instrument to identify knee articular cartilage abnormalities compared with arthroscopy? (2) Is MRI a sensitive tool that can be utilized to identify early cartilage degeneration? Systematic review. A systematic search was performed in November 2010 using PubMed MEDLINE (from 1966), CINAHL (from 1982), SPORTDiscus (from 1985), SCOPUS (from 1996), and EMBASE (from 1974) databases. Fourteen level I and 13 level II studies were identified that met inclusion criteria and provided information related to diagnostic performance of MRI compared with arthroscopic evaluation. The diagnostic performance of MRI demonstrated a large range of sensitivities, specificities, and accuracies. The sensitivity for identifying articular cartilage abnormalities in the knee joint was reported between 26% and 96%. Specificity and accuracy were reported between 50% and 100% and between 49% and 94%, respectively. The sensitivity, specificity, and accuracy for identifying early osteoarthritis were reported between 0% and 86%, 48% and 95%, and 5% and 94%, respectively. As a result of inconsistencies between imaging techniques and methodological shortcomings of many of the studies, a meta-analysis was not performed, and it was difficult to fully synthesize the information to state firm conclusions about the diagnostic performance of MRI. There is evidence in some MRI protocols that MRI is a relatively valid, sensitive, specific, accurate, and reliable clinical tool for identifying articular cartilage degeneration. Because of heterogeneity of MRI sequences, it is not possible to make definitive conclusions regarding its global clinical utility for guiding diagnosis and treatment strategies. Traumatic sports injuries to the knee may be significant precursor events to early onset of posttraumatic osteoarthritis. Magnetic resonance imaging may aid in early identification of structural injuries to articular cartilage as evidenced by articular cartilage degeneration grading.

  13. The Clinical Utility and Diagnostic Performance of MRI for Identification of Early and Advanced Knee Osteoarthritis: A Systematic Review

    PubMed Central

    Quatman, Carmen E.; Hettrich, Carolyn M.; Schmitt, Laura C.; Spindler, Kurt P.

    2013-01-01

    Background Current diagnostic strategies for detection of structural articular cartilage abnormalities, the earliest structural signs of osteoarthritis, often do not capture the condition until it is too far advanced for the most potential benefit of non-invasive interventions. Purpose Systematically review the literature relative to the following questions: (1) Is MRI a valid, sensitive, specific, accurate and reliable instrument to identify knee articular cartilage abnormalities compared to arthroscopy? (2) Is MRI a sensitive tool that can be utilized to identify early cartilage degeneration? Study Design Systematic Review Methods A systematic search was performed in November 2010 using PubMed MEDLINE (from 1966), CINAHL (from 1982), SPORTDiscus (from 1985), and SCOPUS (from 1996) databases. Results Fourteen level I and 13 level II studies were identified that met inclusion criteria and provided information related to diagnostic performance of MRI compared to arthroscopic evaluation. The diagnostic performance of MRI demonstrated a large range of sensitivities, specificities, and accuracies. The sensitivity for identifying articular cartilage abnormalities in the knee joint was reported between 26–96%. Specificity and accuracy was reported between 50–100% and 49–94%, respectively. The sensitivity, specificity, and accuracy for identifying early osteoarthritis were reported between 0–86%, 48–95%, and 5–94%, respectively. As a result of inconsistencies between imaging techniques and methodological shortcomings of many of the studies, a meta-analysis was not performed and it was difficult to fully synthesize the information to state firm conclusions about the diagnostic performance of MRI. Conclusions There is evidence in some MRI protocols that MRI is a relatively valid, sensitive, specific, accurate, and reliable clinical tool for identifying articular cartilage degeneration. Due to heterogeneity of MRI sequences it is not possible to make definitive conclusions regarding its global clinical utility for guiding diagnosis and treatment strategies. Clinical Relevance Traumatic sports injuries to the knee may be significant precursor events to early onset of posttraumatic osteoarthritis. MRI may aid in early identification of structural injuries to articular cartilage as evidenced by articular cartilage degeneration grading. PMID:21730207

  14. Pinpointing Predation Events: A different molecular approach.

    USDA-ARS?s Scientific Manuscript database

    A glassy-winged sharpshooter (GWSS), Homalodisca vitripennis, protien marking system has been developed as a diagnostic tool for quantifying predation rates via gut content analysis. A field study was conducted to quantify predation rates on each of the GWSS lifestages. Specifically, two GWSS nymp...

  15. Replication and Comparison of the Newly Proposed ADOS-2, Module 4 Algorithm in ASD without ID: A Multi-site Study

    PubMed Central

    Pugliese, Cara E.; Kenworthy, Lauren; Bal, Vanessa Hus; Wallace, Gregory L; Yerys, Benjamin E; Maddox, Brenna B.; White, Susan W.; Popal, Haroon; Armour, Anna Chelsea; Miller, Judith; Herrington, John D.; Schultz, Robert T.; Martin, Alex; Anthony, Laura Gutermuth

    2015-01-01

    Recent updates have been proposed to the Autism Diagnostic Observation Schedule-2 Module 4 diagnostic algorithm. This new algorithm, however, has not yet been validated in an independent sample without intellectual disability (ID). This multi-site study compared the original and revised algorithms in individuals with ASD without ID. The revised algorithm demonstrated increased sensitivity, but lower specificity in the overall sample. Estimates were highest for females, individuals with a verbal IQ below 85 or above 115, and ages 16 and older. Best practice diagnostic procedures should include the Module 4 in conjunction with other assessment tools. Balancing needs for sensitivity and specificity depending on the purpose of assessment (e.g., clinical vs. research) and demographic characteristics mentioned above will enhance its utility. PMID:26385796

  16. Generation and characterization of monoclonal antibodies against Rift Valley fever virus nucleoprotein.

    PubMed

    Fafetine, J M; Domingos, A; Antunes, S; Esteves, A; Paweska, J T; Coetzer, J A W; Rutten, V P M G; Neves, L

    2013-11-01

    Due to the unpredictable and explosive nature of Rift Valley fever (RVF) outbreaks, rapid and accurate diagnostic assays for low-resource settings are urgently needed. To improve existing diagnostic assays, monoclonal antibodies (MAbs) specific for the nucleocapsid protein of RVF virus (RVFV) were produced and characterized. Four IgG2a MAbs showed specific binding to denatured nucleocapsid protein, both from a recombinant source and from inactivated RVFV, in Western blot analysis and in an enzyme-linked immunosorbent assay (ELISA). Cross-reactivity with genetically related and non-related arboviruses including Bunyamwera and Calovo viruses (Bunyaviridae family), West Nile and Dengue-2 viruses (Flaviviridae family), and Sindbis and Chikungunya viruses (Togaviridae family) was not detected. These MAbs represent a useful tool for the development of rapid diagnostic assays for early recognition of RVF. © 2013 Blackwell Verlag GmbH.

  17. Diagnosis of scrub typhus.

    PubMed

    Janardhanan, Jeshina; Trowbridge, Paul; Varghese, George M

    2014-12-01

    Scrub typhus is an acute febrile illness that, if untreated, can result in considerable morbidity and mortality. One of the primary reasons for delays in the treatment of this potentially fatal infection is the difficulty in diagnosing the condition. Diagnosis is often complicated because of the combination of non-specific symptoms that overlap with other infections commonly found in endemic areas and the poor available diagnostics. In the majority of the endemic settings, diagnosis still relies on the Weil-Felix test, which is neither sensitive nor specific. Other methods of testing have become available, but at this time, these remain insufficient to provide the rapid point-of-care diagnostics that would be necessary to significantly change the management of this infection by providers in endemic areas. This article reviews the currently available diagnostic tools for scrub typhus and their utility in the clinical setting.

  18. Designing a training tool for imaging mental models

    NASA Technical Reports Server (NTRS)

    Dede, Christopher J.; Jayaram, Geetha

    1990-01-01

    The training process can be conceptualized as the student acquiring an evolutionary sequence of classification-problem solving mental models. For example a physician learns (1) classification systems for patient symptoms, diagnostic procedures, diseases, and therapeutic interventions and (2) interrelationships among these classifications (e.g., how to use diagnostic procedures to collect data about a patient's symptoms in order to identify the disease so that therapeutic measures can be taken. This project developed functional specifications for a computer-based tool, Mental Link, that allows the evaluative imaging of such mental models. The fundamental design approach underlying this representational medium is traversal of virtual cognition space. Typically intangible cognitive entities and links among them are visible as a three-dimensional web that represents a knowledge structure. The tool has a high degree of flexibility and customizability to allow extension to other types of uses, such a front-end to an intelligent tutoring system, knowledge base, hypermedia system, or semantic network.

  19. The Diagnostic Accuracy of Cytology for the Diagnosis of Hepatobiliary and Pancreatic Cancers.

    PubMed

    Al-Hajeili, Marwan; Alqassas, Maryam; Alomran, Astabraq; Batarfi, Bashaer; Basunaid, Bashaer; Alshail, Reem; Alaydarous, Shahad; Bokhary, Rana; Mosli, Mahmoud

    2018-06-13

    Although cytology testing is considered a valuable method to diagnose tumors that are difficult to access such as hepato-biliary-pancreatic (HBP) malignancies, its diagnostic accuracy remains unclear. We therefore aimed to investigate the diagnostic accuracy of cytology testing for HBP tumors. We performed a retrospective study of all cytology samples that were used to confirm radiologically detected HBP tumors between 2002 and 2016. The cytology techniques used in our center included fine needle aspiration (FNA), brush cytology, and aspiration of bile. Sensitivity, specificity, positive and negative predictive values, and likelihood ratios were calculated in comparison to histological confirmation. From a total of 133 medical records, we calculated an overall sensitivity of 76%, specificity of 74%, a negative likelihood ratio of 0.30, and a positive likelihood ratio of 2.9. Cytology was more accurate in diagnosing lesions of the liver (sensitivity 79%, specificity 57%) and biliary tree (sensitivity 100%, specificity 50%) compared to pancreatic (sensitivity 60%, specificity 83%) and gallbladder lesions (sensitivity 50%, specificity 85%). Cytology was more accurate in detecting primary cancers (sensitivity 77%, specificity 73%) when compared to metastatic cancers (sensitivity 73%, specificity 100%). FNA was the most frequently used cytological technique to diagnose HBP lesions (sensitivity 78.8%). Cytological testing is efficient in diagnosing HBP cancers, especially for hepatobiliary tumors. Given its relative simplicity, cost-effectiveness, and paucity of alternative diagnostic methods, cytology should still be considered as a first-line tool for diagnosing HBP malignancies. © 2018 S. Karger AG, Basel.

  20. Novel calibration tools and validation concepts for microarray-based platforms used in molecular diagnostics and food safety control.

    PubMed

    Brunner, C; Hoffmann, K; Thiele, T; Schedler, U; Jehle, H; Resch-Genger, U

    2015-04-01

    Commercial platforms consisting of ready-to-use microarrays printed with target-specific DNA probes, a microarray scanner, and software for data analysis are available for different applications in medical diagnostics and food analysis, detecting, e.g., viral and bacteriological DNA sequences. The transfer of these tools from basic research to routine analysis, their broad acceptance in regulated areas, and their use in medical practice requires suitable calibration tools for regular control of instrument performance in addition to internal assay controls. Here, we present the development of a novel assay-adapted calibration slide for a commercialized DNA-based assay platform, consisting of precisely arranged fluorescent areas of various intensities obtained by incorporating different concentrations of a "green" dye and a "red" dye in a polymer matrix. These dyes present "Cy3" and "Cy5" analogues with improved photostability, chosen based upon their spectroscopic properties closely matching those of common labels for the green and red channel of microarray scanners. This simple tool allows to efficiently and regularly assess and control the performance of the microarray scanner provided with the biochip platform and to compare different scanners. It will be eventually used as fluorescence intensity scale for referencing of assays results and to enhance the overall comparability of diagnostic tests.

  1. Diagnostic accuracy of an identification tool for localized neuropathic pain based on the IASP criteria.

    PubMed

    Mayoral, Víctor; Pérez-Hernández, Concepción; Muro, Inmaculada; Leal, Ana; Villoria, Jesús; Esquivias, Ana

    2018-04-27

    Based on the clear neuroanatomical delineation of many neuropathic pain (NP) symptoms, a simple tool for performing a short structured clinical encounter based on the IASP diagnostic criteria was developed to identify NP. This study evaluated its accuracy and usefulness. A case-control study was performed in 19 pain clinics within Spain. A pain clinician used the experimental screening tool (the index test, IT) to assign the descriptions of non-neuropathic (nNP), non-localized neuropathic (nLNP), and localized neuropathic (LNP) to the patients' pain conditions. The reference standard was a formal clinical diagnosis provided by another pain clinician. The accuracy of the IT was compared with that of the Douleur Neuropathique en 4 questions (DN4) and the Leeds Assessment of Neuropathic Signs and Symptoms (LANSS). Six-hundred and sixty-six patients were analyzed. There was a good agreement between the IT and the reference standard (kappa =0.722). The IT was accurate in distinguishing between LNP and nLNP (83.2% sensitivity, 88.2% specificity), between LNP and the other pain categories (nLNP + nNP) (80.0% sensitivity, 90.7% specificity), and between NP and nNP (95.5% sensitivity, 89.1% specificity). The accuracy in distinguishing between NP and nNP was comparable with that of the DN4 and the LANSS. The IT took a median of 10 min to complete. A novel instrument based on an operationalization of the IASP criteria can not only discern between LNP and nLNP, but also provide a high level of diagnostic certainty about the presence of NP after a short clinical encounter.

  2. The diagnostic value of pepsin detection in saliva for gastro-esophageal reflux disease: a preliminary study from China.

    PubMed

    Du, Xing; Wang, Feng; Hu, Zhiwei; Wu, Jimin; Wang, Zhonggao; Yan, Chao; Zhang, Chao; Tang, Juan

    2017-10-17

    None of current diagnostic methods has been proven to be a reliable tool for gastro-esophageal reflux disease (GERD). Pepsin in saliva has been proposed as a promising diagnostic biomarker for gastro-esophageal reflux. We aimed to determine the diagnostic value of salivary pepsin detection for GERD. Two hundred and fifty patients with symptoms suggestive of GERD and 35 asymptomatic healthy volunteers provided saliva on morning waking, after lunch and dinner for pepsin determination using the Peptest lateral flow device. All patients underwent 24-h multichannel intraluminal impedance pH (24-h MII-pH) monitoring and upper gastrointestinal endoscopy. Based on 24-h MII-pH and endoscopy study, patients were defined as GERD (abnormal MII-pH results and/or reflux esophagitis) and non-GERD otherwise. Patients with GERD had a higher prevalence of pepsin in saliva and higher pepsin concentration than patients with non-GERD and healthy controls (P < 0.001 for all). The pepsin test had a sensitivity of 73% and a specificity of 88.3% for diagnosing GERD using the optimal cut-off value of 76 ng/mL. Postprandial saliva samples collected when the symptoms occurred had a more powerful ability to identify GERD. Salivary pepsin test had moderate diagnostic value for GERD. It may be a promising tool to replace the use of currently invasive tools with advantages of non-invasive, easy to perform and cost effective. ChiCTR-DDD-16009506 (date of registration: October 20, 2016).

  3. Diagnostic accuracy of lymphoma established by fine-needle aspiration cytological biopsy

    NASA Astrophysics Data System (ADS)

    Delyuzar; Amir, Z.; Suryadi, D.

    2018-03-01

    Based on Globocan data in 2012, it is estimated that about 14,495 Indonesians suffer from lymphoma, both Hodgkin’s lymphoma, and non-Hodgkin’s lymphoma. Some areas of specialization still doubt the accuracy of cytology diagnosis of fine needle aspiration biopsy.This study is a diagnostic test with a cross sectional analytic design to see how the cytology diagnostic accuracy of fine needle aspiration aspirate in lymphoma. It was in Department of Anatomical Pathology Faculty of Medicine USU, Haji Adam Malik Hospital, Dr.Pirngadi hospital, or private clinic in Medan. Peripheral cytology technique biopsy of fine needle aspiration on lymph node subsequently stained with Giemsa, when the cytology of lymphoma is obtained and confirmed by histopathologic examination. Cytology and histopathologic examination will be tested by Diagnostic Test and assessed for its sensitivity and specificity. The diagnostic of lymphoma cytology provides 93.33% sensitivity and 92.31% specificity when confirmed by histopathological examination. Positive predictive value and negative predictive value of 96.55% and 85.71% respectively. In conclusion, the cytology of fine needle aspiration biopsy is accurate enough to be used as a diagnostic tool, so it is advisable to establish a lymphoma diagnosis to perform a needle aspiration biopsy examination.

  4. Treatment Options to Manage Wound Biofilm

    PubMed Central

    Jones, Curtis E.; Kennedy, John P.

    2012-01-01

    Background Bioburden is an accepted barrier to chronic wound healing. Defining the significance, phenotype, clinical classification, and treatment guidelines has been historically lacking of evidence and based on paradigms that do not represent the scientific or clinical reality. The Problem Chronic wound bioburden is typically abundant, polymicrobial, and extremely diverse. These microbes naturally adopt biofilm phenotypes, which are quite often viable but not culturable, thereby going undetected. The failures of culture-based detection have led to abandonment of routine bioburden evaluation and aggressive treatment or, worse, to assume bioburden is not a significant barrier. Predictably, treatment regimens to address biofilm phenotypes lagged behind our diagnostic tools and understanding. Basic/Clinical Science Advances Microbial DNA-based diagnostic tools and treatment regimens have emerged, which provide and leverage objective information, resulting in a dramatic impact on outcomes. Relevance to Clinical Care Modern medicine demands decisions based on objective evidence. The diagnostic and treatment protocols reviewed herein empower clinicians to practice modern medicine with regard to bioburden, with DNA level certainty. Conclusion Bioburden is a significant barrier to healing for all chronic wounds. Molecular diagnostics provide the first objective means of assessing wound bioburden. The accuracy and comprehensive data from such diagnostic methodologies provide clinicians with the ability to employ patient-specific treatment options, targeted to each patient's microbial wound census. Based on current outcomes data, the most effective therapeutic options are topical (TPL) antibiofilm agents (ABF) combined with TPL antibiotics (ABX). In specific patients, systemic ABX and selective biocides are also appropriate, but not exclusive of ABF combined with TPL ABX. PMID:24527291

  5. Aptamers in Diagnostics and Treatment of Viral Infections

    PubMed Central

    Wandtke, Tomasz; Woźniak, Joanna; Kopiński, Piotr

    2015-01-01

    Aptamers are in vitro selected DNA or RNA molecules that are capable of binding a wide range of nucleic and non-nucleic acid molecules with high affinity and specificity. They have been conducted through the process known as SELEX (Systematic Evolution of Ligands by Exponential Enrichment). It serves to reach specificity and considerable affinity to target molecules, including those of viral origin, both proteins and nucleic acids. Properties of aptamers allow detecting virus infected cells or viruses themselves and make them competitive to monoclonal antibodies. Specific aptamers can be used to interfere in each stage of the viral replication cycle and also inhibit its penetration into cells. Many current studies have reported possible application of aptamers as a treatment or diagnostic tool in viral infections, e.g., HIV (Human Immunodeficiency Virus), HBV (Hepatitis B Virus), HCV (Hepatitis C Virus), SARS (Severe Acute Respiratory Syndrome), H5N1 avian influenza and recently spread Ebola. This review presents current developments of using aptamers in the diagnostics and treatment of viral diseases. PMID:25690797

  6. Two non-invasive diagnostic tools for invasive aspergilosis: (1-3)-beta-D-glucan and the galactomannan assay.

    PubMed

    Kelaher, Amy

    2006-01-01

    Invasive aspergillosis (IA) is a serious cause of morbidity and mortality among immunocompromised patients. Prompt and non-invasive methods for diagnosing IA are needed to improve the management of this life-threatening infection in patients with hematological disorders. In summary, this retrospective review of studies performed on the two assays finds that both assays have high sensitivity and specificity but are more useful when used together as a diagnostic strategy for patients with invasive aspergillosis.

  7. Portable Biomarker Detection with Magnetic Nanotags

    PubMed Central

    Hall, Drew A.; Wang, Shan X.; Murmann, Boris; Gaster, Richard S.

    2012-01-01

    This paper presents a hand-held, portable biosensor platform for quantitative biomarker measurement. By combining magnetic nanoparticle (MNP) tags with giant magnetoresistive (GMR) spin-valve sensors, the hand-held platform achieves highly sensitive (picomolar) and specific biomarker detection in less than 20 minutes. The rapid analysis and potential low cost make this technology ideal for point-of-care (POC) diagnostics. Furthermore, this platform is able to detect multiple biomarkers simultaneously in a single assay, creating a promising diagnostic tool for a vast number of applications. PMID:22495252

  8. Using Facet Clusters to Guide Teacher Professional Development

    NASA Astrophysics Data System (ADS)

    Seeley, Lane; DeWater, L. S.; Vokos, S.; Kraus, P.

    2006-12-01

    The Department of Physics and the School of Education at Seattle Pacific University, together with FACET Innovations, LLC, are beginning the second year of a five-year NSF TPC project, Improving the Effectiveness of Teacher Diagnostic Skills and Tools. We are working in partnership with school districts in Washington State to help teachers make their classrooms into better diagnostic learning environments. In this talk, we describe initial efforts to construct content-rich professional development courses for teachers, which are infused with diagnostic assessment that target the fine structure of student ideas in specific topical areas. * Supported in part by NSF grant #ESI-0455796, The Boeing Corporation, and the SPU Science Initiative.

  9. Laser machined plastic laminates. Towards portable diagnostic devices for use in low resource environments

    DOE PAGES

    Harper, Jason C.; Carson, Bryan D.; Bachand, George D.; ...

    2015-07-14

    Despite significant progress in development of bioanalytical devices cost, complexity, access to reagents and lack of infrastructure have prevented use of these technologies in resource-limited regions. To provide a sustainable tool in the global effort to combat infectious diseases the diagnostic device must be low cost, simple to operate and read, robust, and have sensitivity and specificity comparable to laboratory analysis. Thus, in this mini-review we describe recent work using laser machined plastic laminates to produce diagnostic devices that are capable of a wide variety of bioanalytical measurements and show great promise towards future use in low-resource environments.

  10. Photoacoustic and ultrasound characterization of bone composition

    NASA Astrophysics Data System (ADS)

    Lashkari, Bahman; Yang, Lifeng; Liu, Lixian; Tan, Joel W. Y.; Mandelis, Andreas

    2015-02-01

    This study examines the sensitivity and specificity of backscattered ultrasound (US) and backscattering photoacoustic (PA) signals for bone composition variation assessment. The conventional approach in the evaluation of bone health relies on measurement of bone mineral density (BMD). Although, a crucial and probably the most important parameter, BMD is not the only factor defining the bone health. New trends in osteoporosis research, also pursue the changes in collagen content and cross-links with bone diseases and aging. Therefore, any non-invasive method that can assess any of these parameters can improve the diagnostic tools and also can help with the biomedical studies on the diseases themselves. Our previous studies show that both US and PA are responsive to changes in the BMD, PA is, in addition, sensitive to changes in the collagen content of the bone. Measurements were performed on bone samples before and after mild demineralization and decollagenization at the exact same points. Results show that combining both modalities can enhance the sensitivity and specificity of diagnostic tool.

  11. Quality and reporting of diagnostic accuracy studies in TB, HIV and malaria: evaluation using QUADAS and STARD standards.

    PubMed

    Fontela, Patricia Scolari; Pant Pai, Nitika; Schiller, Ian; Dendukuri, Nandini; Ramsay, Andrew; Pai, Madhukar

    2009-11-13

    Poor methodological quality and reporting are known concerns with diagnostic accuracy studies. In 2003, the QUADAS tool and the STARD standards were published for evaluating the quality and improving the reporting of diagnostic studies, respectively. However, it is unclear whether these tools have been applied to diagnostic studies of infectious diseases. We performed a systematic review on the methodological and reporting quality of diagnostic studies in TB, malaria and HIV. We identified diagnostic accuracy studies of commercial tests for TB, malaria and HIV through a systematic search of the literature using PubMed and EMBASE (2004-2006). Original studies that reported sensitivity and specificity data were included. Two reviewers independently extracted data on study characteristics and diagnostic accuracy, and used QUADAS and STARD to evaluate the quality of methods and reporting, respectively. Ninety (38%) of 238 articles met inclusion criteria. All studies had design deficiencies. Study quality indicators that were met in less than 25% of the studies included adequate description of withdrawals (6%) and reference test execution (10%), absence of index test review bias (19%) and reference test review bias (24%), and report of uninterpretable results (22%). In terms of quality of reporting, 9 STARD indicators were reported in less than 25% of the studies: methods for calculation and estimates of reproducibility (0%), adverse effects of the diagnostic tests (1%), estimates of diagnostic accuracy between subgroups (10%), distribution of severity of disease/other diagnoses (11%), number of eligible patients who did not participate in the study (14%), blinding of the test readers (16%), and description of the team executing the test and management of indeterminate/outlier results (both 17%). The use of STARD was not explicitly mentioned in any study. Only 22% of 46 journals that published the studies included in this review required authors to use STARD. Recently published diagnostic accuracy studies on commercial tests for TB, malaria and HIV have moderate to low quality and are poorly reported. The more frequent use of tools such as QUADAS and STARD may be necessary to improve the methodological and reporting quality of future diagnostic accuracy studies in infectious diseases.

  12. Quality and Reporting of Diagnostic Accuracy Studies in TB, HIV and Malaria: Evaluation Using QUADAS and STARD Standards

    PubMed Central

    Fontela, Patricia Scolari; Pant Pai, Nitika; Schiller, Ian; Dendukuri, Nandini; Ramsay, Andrew; Pai, Madhukar

    2009-01-01

    Background Poor methodological quality and reporting are known concerns with diagnostic accuracy studies. In 2003, the QUADAS tool and the STARD standards were published for evaluating the quality and improving the reporting of diagnostic studies, respectively. However, it is unclear whether these tools have been applied to diagnostic studies of infectious diseases. We performed a systematic review on the methodological and reporting quality of diagnostic studies in TB, malaria and HIV. Methods We identified diagnostic accuracy studies of commercial tests for TB, malaria and HIV through a systematic search of the literature using PubMed and EMBASE (2004–2006). Original studies that reported sensitivity and specificity data were included. Two reviewers independently extracted data on study characteristics and diagnostic accuracy, and used QUADAS and STARD to evaluate the quality of methods and reporting, respectively. Findings Ninety (38%) of 238 articles met inclusion criteria. All studies had design deficiencies. Study quality indicators that were met in less than 25% of the studies included adequate description of withdrawals (6%) and reference test execution (10%), absence of index test review bias (19%) and reference test review bias (24%), and report of uninterpretable results (22%). In terms of quality of reporting, 9 STARD indicators were reported in less than 25% of the studies: methods for calculation and estimates of reproducibility (0%), adverse effects of the diagnostic tests (1%), estimates of diagnostic accuracy between subgroups (10%), distribution of severity of disease/other diagnoses (11%), number of eligible patients who did not participate in the study (14%), blinding of the test readers (16%), and description of the team executing the test and management of indeterminate/outlier results (both 17%). The use of STARD was not explicitly mentioned in any study. Only 22% of 46 journals that published the studies included in this review required authors to use STARD. Conclusion Recently published diagnostic accuracy studies on commercial tests for TB, malaria and HIV have moderate to low quality and are poorly reported. The more frequent use of tools such as QUADAS and STARD may be necessary to improve the methodological and reporting quality of future diagnostic accuracy studies in infectious diseases. PMID:19915664

  13. Diagnostic indices for vertiginous diseases

    PubMed Central

    2010-01-01

    Background Vertigo and dizziness are symptoms which are reported frequently in clinical practice. We aimed to develop diagnostic indices for four prevalent vertiginous diseases: benign paroxysmal positional vertigo (BPPV), Menière's disease (MD), vestibular migraine (VM), and phobic postural vertigo (PPV). Methods Based on a detailed questionnaire handed out to consecutive patients presenting for the first time in our dizziness clinic we preselected a set of seven questions with desirable diagnostic properties when compared with the final diagnosis after medical workup. Using exact logistic regression analysis diagnostic scores, each comprising of four to six items that can simply be added up, were built for each of the four diagnoses. Results Of 193 patients 131 questionnaires were left after excluding those with missing consent or data. Applying the suggested cut-off points, sensitivity and specificity were 87.5 and 93.5% for BPPV, 100 and 87.4% for MD, 92.3 and 83.7% for VM, 73.7 and 84.1% for PPV, respectively. By changing the cut-off points sensitivity and specificity can be adjusted to meet diagnostic needs. Conclusions The diagnostic indices showed promising diagnostic properties. Once further validated, they could provide an ease to use and yet flexible tool for screening vertigo in clinical practice and epidemiological research. PMID:20973968

  14. Diagnostic Accuracy of Rating Scales for Attention-Deficit/Hyperactivity Disorder: A Meta-analysis.

    PubMed

    Chang, Ling-Yin; Wang, Mei-Yeh; Tsai, Pei-Shan

    2016-03-01

    The Child Behavior Checklist-Attention Problem (CBCL-AP) scale and Conners Rating Scale-Revised (CRS-R) are commonly used behavioral rating scales for diagnosing attention-deficit/hyperactivity disorder (ADHD) in children and adolescents. To evaluate and compare the diagnostic performance of CBCL-AP and CRS-R in diagnosing ADHD in children and adolescents. PubMed, Ovid Medline, and other relevant electronic databases were searched for articles published up to May 2015. We included studies evaluating the diagnostic performance of either CBCL-AP scale or CRS-R for diagnosing ADHD in pediatric populations in comparison with a defined reference standard. Bivariate random effects models were used for pooling and comparing diagnostic performance. We identified and evaluated 14 and 11 articles on CBCL-AP and CRS-R, respectively. The results revealed pooled sensitivities of 0.77, 0.75, 0.72, and 0.83 and pooled specificities of 0.73, 0.75, 0.84, and 0.84 for CBCL-AP, Conners Parent Rating Scale-Revised, Conners Teacher Rating Scale-Revised, and Conners Abbreviated Symptom Questionnaire (ASQ), respectively. No difference was observed in the diagnostic performance of the various scales. Study location, age of participants, and percentage of female participants explained the heterogeneity in the specificity of the CBCL-AP. CBCL-AP and CRS-R both yielded moderate sensitivity and specificity in diagnosing ADHD. According to the comparable diagnostic performance of all examined scales, ASQ may be the most effective diagnostic tool in assessing ADHD because of its brevity and high diagnostic accuracy. CBCL is recommended for more comprehensive assessments. Copyright © 2016 by the American Academy of Pediatrics.

  15. Performance of in silico prediction tools for the classification of rare BRCA1/2 missense variants in clinical diagnostics.

    PubMed

    Ernst, Corinna; Hahnen, Eric; Engel, Christoph; Nothnagel, Michael; Weber, Jonas; Schmutzler, Rita K; Hauke, Jan

    2018-03-27

    The use of next-generation sequencing approaches in clinical diagnostics has led to a tremendous increase in data and a vast number of variants of uncertain significance that require interpretation. Therefore, prediction of the effects of missense mutations using in silico tools has become a frequently used approach. Aim of this study was to assess the reliability of in silico prediction as a basis for clinical decision making in the context of hereditary breast and/or ovarian cancer. We tested the performance of four prediction tools (Align-GVGD, SIFT, PolyPhen-2, MutationTaster2) using a set of 236 BRCA1/2 missense variants that had previously been classified by expert committees. However, a major pitfall in the creation of a reliable evaluation set for our purpose is the generally accepted classification of BRCA1/2 missense variants using the multifactorial likelihood model, which is partially based on Align-GVGD results. To overcome this drawback we identified 161 variants whose classification is independent of any previous in silico prediction. In addition to the performance as stand-alone tools we examined the sensitivity, specificity, accuracy and Matthews correlation coefficient (MCC) of combined approaches. PolyPhen-2 achieved the lowest sensitivity (0.67), specificity (0.67), accuracy (0.67) and MCC (0.39). Align-GVGD achieved the highest values of specificity (0.92), accuracy (0.92) and MCC (0.73), but was outperformed regarding its sensitivity (0.90) by SIFT (1.00) and MutationTaster2 (1.00). All tools suffered from poor specificities, resulting in an unacceptable proportion of false positive results in a clinical setting. This shortcoming could not be bypassed by combination of these tools. In the best case scenario, 138 families would be affected by the misclassification of neutral variants within the cohort of patients of the German Consortium for Hereditary Breast and Ovarian Cancer. We show that due to low specificities state-of-the-art in silico prediction tools are not suitable to predict pathogenicity of variants of uncertain significance in BRCA1/2. Thus, clinical consequences should never be based solely on in silico forecasts. However, our data suggests that SIFT and MutationTaster2 could be suitable to predict benignity, as both tools did not result in false negative predictions in our analysis.

  16. Testing the woman abuse screening tool to identify intimate partner violence in Indonesia.

    PubMed

    Iskandar, Livia; Braun, Kathryn L; Katz, Alan R

    2015-04-01

    Intimate Partner Violence (IPV) is a global public health problem. IPV prevalence in Indonesia has been estimated to be less than 1%, based on reported cases. It is likely that IPV prevalence is underreported in Indonesia, as it is in many other countries. Screening for IPV has been found to increase IPV identification, but no screening tools are in use in Indonesia. The aim of this study was to test the translated Woman Abuse Screening Tool (WAST) for detecting IPV in Indonesia. The WAST was tested against a diagnostic interview by a trained psychologist on 240 women attending two Primary Health Centers in Jakarta. IPV prevalence and the reliability, sensitivity, and specificity of the WAST were estimated. Prevalence of IPV by diagnostic interview was 36.3%, much higher than published estimates. The most common forms of IPV identified were psychological (85%) and physical abuse (24%). Internal reliability of the WAST was high (α = .801). A WAST score of 13 (out of 24) is the recommended cutoff for identifying IPV, but only 17% of the Indonesian sample scored 13 or higher. Test sensitivity of the WAST with a cutoff score of 13 was only 41.9%, with a specificity of 96.8%. With a cutoff score of 10, the sensitivity improved to 84.9%, while the specificity decreased to 61.0%. Use of the WAST with a cutoff score of 10 provides good sensitivity and reasonable specificity and would provide a much-needed screening tool for use in Indonesia. Although a lower cutoff would yield a greater proportion of false positives, most of the true cases would be identified, increasing the possibility that women experiencing abuse would receive needed assistance. © The Author(s) 2014.

  17. The diagnostic test accuracy of magnetic resonance imaging, magnetic resonance arthrography and computer tomography in the detection of chondral lesions of the hip.

    PubMed

    Smith, Toby O; Simpson, Michael; Ejindu, Vivian; Hing, Caroline B

    2013-04-01

    The purpose of this study was to assess the diagnostic test accuracy of magnetic resonance imaging (MRI), magnetic resonance arthrography (MRA) and multidetector arrays in CT arthrography (MDCT) for assessing chondral lesions in the hip joint. A review of the published and unpublished literature databases was performed to identify all studies reporting the diagnostic test accuracy (sensitivity/specificity) of MRI, MRA or MDCT for the assessment of adults with chondral (cartilage) lesions of the hip with surgical comparison (arthroscopic or open) as the reference test. All included studies were reviewed using the quality assessment of diagnostic accuracy studies appraisal tool. Pooled sensitivity, specificity, likelihood ratios and diagnostic odds ratios were calculated with 95 % confidence intervals using a random-effects meta-analysis for MRI, MRA and MDCT imaging. Eighteen studies satisfied the eligibility criteria. These included 648 hips from 637 patients. MRI indicated a pooled sensitivity of 0.59 (95 % CI: 0.49-0.70) and specificity of 0.94 (95 % CI: 0.90-0.97), and MRA sensitivity and specificity values were 0.62 (95 % CI: 0.57-0.66) and 0.86 (95 % CI: 0.83-0.89), respectively. The diagnostic test accuracy for the detection of hip joint cartilage lesions is currently superior for MRI compared with MRA. There were insufficient data to perform meta-analysis for MDCT or CTA protocols. Based on the current limited diagnostic test accuracy of the use of magnetic resonance or CT, arthroscopy remains the most accurate method of assessing chondral lesions in the hip joint.

  18. It's time to change perspective! New diagnostic tools for lateral elbow pain.

    PubMed

    Arrigoni, P; Cucchi, D; Menon, A; Randelli, P

    2017-12-01

    The presence of intra-articular findings that may complement the extra-articular pathology in lateral epicondilytis has been suggested, and a role for minor instability of the elbow as part of the causative process of this disease has been postulated. This study was designed to describe two new clinical tests, aimed at detecting intra-articular pathology in patients affected by recalcitrant lateral epicondylitis and investigate their diagnostic performance. Ten patients suffering of atraumatic lateral elbow pain unresponsive to conservative treatment were considered in this study. Two clinical tests were developed and administrated prior to arthroscopy: Supination and Antero-Lateral pain Test (SALT); Posterior Elbow Pain by Palpation-Extension of the Radiocapitellar joint (PEPPER). Sensitivity, specificity, predictive values and accuracy of SALT and PEPPER as diagnostic tests for seven intra-articular findings were calculated. In 90% of the patients, at least one test was positive. All patients with signs of lateral ligamentous patholaxity or intra-articular abnormal findings had a positive response to at least one of the two tests. SALT proved to have a high sensitivity but a low specificity and is accurate in detecting the presence of intra-articular abnormal findings, especially synovitis. PEPPER test was sensible, specific and accurate in the detection of radial head chondropathy. Two new diagnostic tests (SALT and PEPPER) were specifically designed to evoke pain from intra-articular structures. These tests could be a valid support in the diagnostic algorithm of recalcitrant lateral elbow pain. Positive findings may be indicative of a minor instability of the lateral elbow condition. Diagnostic study, development of diagnostic criteria on basis of consecutive patients, level II.

  19. Nucleic Acid-Based Approaches for Detection of Viral Hepatitis

    PubMed Central

    Behzadi, Payam; Ranjbar, Reza; Alavian, Seyed Moayed

    2014-01-01

    Context: To determining suitable nucleic acid diagnostics for individual viral hepatitis agent, an extensive search using related keywords was done in major medical library and data were collected, categorized, and summarized in different sections. Results: Various types of molecular biology tools can be used to detect and quantify viral genomic elements and analyze the sequences. These molecular assays are proper technologies for rapidly detecting viral agents with high accuracy, high sensitivity, and high specificity. Nonetheless, the application of each diagnostic method is completely dependent on viral agent. Conclusions: Despite rapidity, automation, accuracy, cost-effectiveness, high sensitivity, and high specificity of molecular techniques, each type of molecular technology has its own advantages and disadvantages. PMID:25789132

  20. Diagnostic accuracy of serological diagnosis of hepatitis C and B using dried blood spot samples (DBS): two systematic reviews and meta-analyses.

    PubMed

    Lange, Berit; Cohn, Jennifer; Roberts, Teri; Camp, Johannes; Chauffour, Jeanne; Gummadi, Nina; Ishizaki, Azumi; Nagarathnam, Anupriya; Tuaillon, Edouard; van de Perre, Philippe; Pichler, Christine; Easterbrook, Philippa; Denkinger, Claudia M

    2017-11-01

    Dried blood spots (DBS) are a convenient tool to enable diagnostic testing for viral diseases due to transport, handling and logistical advantages over conventional venous blood sampling. A better understanding of the performance of serological testing for hepatitis C (HCV) and hepatitis B virus (HBV) from DBS is important to enable more widespread use of this sampling approach in resource limited settings, and to inform the 2017 World Health Organization (WHO) guidance on testing for HBV/HCV. We conducted two systematic reviews and meta-analyses on the diagnostic accuracy of HCV antibody (HCV-Ab) and HBV surface antigen (HBsAg) from DBS samples compared to venous blood samples. MEDLINE, EMBASE, Global Health and Cochrane library were searched for studies that assessed diagnostic accuracy with DBS and agreement between DBS and venous sampling. Heterogeneity of results was assessed and where possible a pooled analysis of sensitivity and specificity was performed using a bivariate analysis with maximum likelihood estimate and 95% confidence intervals (95%CI). We conducted a narrative review on the impact of varying storage conditions or limits of detection in subsets of samples. The QUADAS-2 tool was used to assess risk of bias. For the diagnostic accuracy of HBsAg from DBS compared to venous blood, 19 studies were included in a quantitative meta-analysis, and 23 in a narrative review. Pooled sensitivity and specificity were 98% (95%CI:95%-99%) and 100% (95%CI:99-100%), respectively. For the diagnostic accuracy of HCV-Ab from DBS, 19 studies were included in a pooled quantitative meta-analysis, and 23 studies were included in a narrative review. Pooled estimates of sensitivity and specificity were 98% (CI95%:95-99) and 99% (CI95%:98-100), respectively. Overall quality of studies and heterogeneity were rated as moderate in both systematic reviews. HCV-Ab and HBsAg testing using DBS compared to venous blood sampling was associated with excellent diagnostic accuracy. However, generalizability is limited as no uniform protocol was applied and most studies did not use fresh samples. Future studies on diagnostic accuracy should include an assessment of impact of environmental conditions common in low resource field settings. Manufacturers also need to formally validate their assays for DBS for use with their commercial assays.

  1. Screening for post-traumatic stress disorder after injury in the pediatric emergency department--a systematic review protocol.

    PubMed

    Odenbach, Jeffrey; Newton, Amanda; Gokiert, Rebecca; Falconer, Cathy; Courchesne, Craig; Campbell, Sandra; Curtis, Sarah J

    2014-03-02

    Pediatric injury is highly prevalent and has significant impact both physically and emotionally. The majority of pediatric injuries are treated in emergency departments (EDs), where treatment of physical injuries is the main focus. In addition to physical trauma, children often experience significant psychological trauma, and the development of acute stress disorder (ASD) and post-traumatic stress disorder (PTSD) is common. The consequences of failing to recognize and treat children with ASD and PTSD are significant and extend into adulthood. Currently, screening guidelines to identify children at risk for developing these stress disorders are not evident in the pediatric emergency setting. The goal of this systematic review is to summarize evidence on the psychometric properties, diagnostic accuracy, and clinical utility of screening tools that identify or predict PTSD secondary to physical injury in children. Specific research objectives are to: (1) identify, describe, and critically evaluate instruments available to screen for PTSD in children; (2) review and synthesize the test-performance characteristics of these tools; and (3) describe the clinical utility of these tools with focus on ED suitability. Computerized databases including MEDLINE, EMBASE, CINAHL, ISI Web of Science and PsycINFO will be searched in addition to conference proceedings, textbooks, and contact with experts. Search terms will include MeSH headings (post-traumatic stress or acute stress), (pediatric or children) and diagnosis. All articles will be screened by title/abstract and articles identified as potentially relevant will be retrieved in full text and assessed by two independent reviewers. Quality assessment will be determined using the QUADAS-2 tool. Screening tool characteristics, including type of instrument, number of items, administration time and training administrators level, will be extracted as well as gold standard diagnostic reference properties and any quantitative diagnostic data (specificity, positive and negative likelihood/odds ratios) where appropriate. Identifying screening tools to recognize children at risk of developing stress disorders following trauma is essential in guiding early treatment and minimizing long-term sequelae of childhood stress disorders. This review aims to identify such screening tools in efforts to improve routine stress disorder screening in the pediatric ED setting. PROSPERO registration: CRD42013004893.

  2. Diagnostic accuracy of contrast-enhanced ultrasound in assessing the therapeutic response to radio frequency ablation for liver tumors: systematic review and meta-analysis.

    PubMed

    Xuan, Min; Zhou, Fengsheng; Ding, Yan; Zhu, Qiaoying; Dong, Ji; Zhou, Hao; Cheng, Jun; Jiang, Xiao; Wu, Pengxi

    2018-04-01

    To review the diagnostic accuracy of contrast-enhanced ultrasound (CEUS) used to detect residual or recurrent liver tumors after radiofrequency ablation (RFA). This technique uses contrast-enhanced computer tomography or/and contrast-enhanced magnetic resonance imaging as the gold standard of investigation. MEDLINE, EMBASE, and COCHRANE were systematically searched for all potentially eligible studies comparing CEUS with the reference standard that follows RFA. Risk of bias and applicability concerns were addressed by adopting the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Pooled point estimates for sensitivity, specificity, positive and negative likelihood ratios, and diagnostic odds ratios (DOR) with 95% CI were computed before plotting the sROC (summary receiver operating characteristic) curve. Meta-regression and subgroup analysis were used to identify the source of the heterogeneity that was detected. Publication bias was evaluated using Deeks' funnel plot asymmetry test. Ten eligible studies on 1162 lesions that occurred between 2001 and 2016 were included in the final analysis. The quality of the included studies assessed by the QUADAS-2 tool was considered reasonable. The pooled sensitivity and specificity of CEUS in detecting residual or recurrent liver tumors had the following values: 0.90 (95% CI 0.85-0.94) and 1.00 (95% CI 0.99-1.00), respectively. Overall DOR was 420.10 (95% CI 142.30-1240.20). The sources of heterogeneity could not be precisely identified by meta-regression or subgroup analysis. No evidence of publication bias was found. This study confirmed that CEUS exhibits high sensitivity and specificity in assessing therapeutic responses to RFA for liver tumors.

  3. Economic implications of resistance to antimalarial drugs.

    PubMed

    Phillips, M; Phillips-Howard, P A

    1996-09-01

    The widespread evolution of drug resistance in malarial parasites has seriously hampered efforts to control this debilitating disease. Chloroquine, the mainstay of malaria treatment for many decades, is now proving largely ineffective in many parts of the world, particularly against the most severe form of malaria--falciparum. Alternative drugs have been developed, but they are frequently less safe and are all between 50 and 700% more expensive than chloroquine. Choice of drug clearly has important budgetary implications and national malaria control programmes need to weigh up the costs and benefits in deciding whether to change to more effective but more expensive drugs. The growth in drug resistance also has implications for the choice of diagnostic tool. Clinical diagnosis of malaria is relatively cheap, but less specific than some technological approaches. As more expensive drugs are employed, the cost of wasted treatment on suspected cases who do not in fact have malaria rises and the more worthwhile it becomes to invest in more specific diagnostic techniques. This paper presents an economic framework for analysing the various malaria drug and diagnostic tool options available. It discusses the nature of the key factors that need to be considered when making choices of malaria treatment (including treatment costs, drug resistance, the costs of treatment failure and compliance) and diagnosis (including diagnosis cost and accuracy, and the often overlooked costs associated with delayed treatment), and uses some simple equations to illustrate the impact of these on the relative cost effectiveness of the alternatives being considered. On the basis of some simplifying assumptions and illustrative calculations, it appears that in many countries more effective drugs and more specific and rapid diagnostic approaches will be worth adopting even although they imply additional expense.

  4. Quality control in diagnostic immunohistochemistry: integrated on-slide positive controls.

    PubMed

    Bragoni, A; Gambella, A; Pigozzi, S; Grigolini, M; Fiocca, R; Mastracci, L; Grillo, F

    2017-11-01

    Standardization in immunohistochemistry is a priority in modern pathology and requires strict quality control. Cost containment has also become fundamental and auditing of all procedures must take into account both these principles. Positive controls must be routinely performed so that their positivity guarantees the appropriateness of the immunohistochemical procedure. The aim of this study is to develop a low cost (utilizing a punch biopsy-PB-tool) procedure to construct positive controls which can be integrated in the patient's tissue slide. Sixteen frequently used control blocks were selected and multiple cylindrical samples were obtained using a 5-mm diameter punch biopsy tool, separately re-embedding them in single blocks. For each diagnostic immunoreaction requiring a positive control, an integrated PB-control section (cut from the appropriate PB-control block) was added to the top right corner of the diagnostic slide before immunostaining. This integrated control technique permitted a saving of 4.75% in total direct lab costs and proved to be technically feasible and reliable. Our proposal is easy to perform and within the reach of all pathology labs, requires easily available tools, its application costs is less than using external paired controls and ensures that a specific control for each slide is always available.

  5. Diagnostic Tools for Acute Anterior Cruciate Ligament Injury: GNRB, Lachman Test, and Telos.

    PubMed

    Ryu, Seung Min; Na, Ho Dong; Shon, Oog Jin

    2018-06-01

    The purpose of this study is to compare the accuracy of the GNRB arthrometer (Genourob), Lachman test, and Telos device (GmbH) in acute anterior cruciate ligament (ACL) injuries and to evaluate the accuracy of each diagnostic tool according to the length of time from injury to examination. From September 2015 to September 2016, 40 cases of complete ACL rupture were reviewed. We divided the time from injury to examination into three periods of 10 days each and analyzed the diagnostic tools according to the time frame. An analysis of the area under the curve (AUC) of a receiver operating characteristic curve showed that all diagnostic tools were fairly informative. The GNRB showed a higher AUC than other diagnostic tools. In 10 cases assessed within 10 days after injury, the GNRB showed statistically significant side-to-side difference in laxity (p<0.001), whereas the Telos test and Lachman test did not show significantly different laxity (p=0.541 and p=0.413, respectively). All diagnostic values of the GNRB were better than other diagnostic tools in acute ACL injuries. The GNRB was more effective in acute ACL injuries examined within 10 days of injury. The GNRB arthrometer can be a useful diagnostic tool for acute ACL injuries.

  6. Value of circulating cell-free DNA analysis as a diagnostic tool for breast cancer: a meta-analysis

    PubMed Central

    Ma, Xuelei; Zhang, Jing; Hu, Xiuying

    2017-01-01

    Objectives The aim of this study was to systematically evaluate the diagnostic value of cell free DNA (cfDNA) for breast cancer. Results Among 308 candidate articles, 25 with relevant diagnostic screening qualified for final analysis. The mean sensitivity, specificity and area under the curve (AUC) of SROC plots for 24 studies that distinguished breast cancer patients from healthy controls were 0.70, 0.87, and 0.9314, yielding a DOR of 32.31. When analyzed in subgroups, the 14 quantitative studies produced sensitivity, specificity, AUC, and a DOR of 0.78, 0.83, 0.9116, and 24.40. The 10 qualitative studies produced 0.50, 0.98, 0.9919, and 68.45. For 8 studies that distinguished malignant breast cancer from benign diseases, the specificity, sensitivity, AUC and DOR were 0.75, 0.79, 0.8213, and 9.49. No covariate factors had a significant correlation with relative DOR. Deek's funnel plots indicated an absence of publication bias. Materials and Methods Databases were searched for studies involving the use of cfDNA to diagnose breast cancer. The studies were analyzed to determine sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio (DOR), and the summary receiver operating characteristic (SROC). Covariates were evaluated for effect on relative DOR. Deek's Funnel plots were generated to measure publication bias. Conclusions Our analysis suggests a promising diagnostic potential of using cfDNA for breast cancer screening, but this diagnostic method is not yet independently sufficient. Further work refining qualitative cfDNA assays will improve the correct diagnosis of breast cancers. PMID:28460452

  7. Rapid bacterial diagnostics via surface enhanced Raman microscopy.

    PubMed

    Premasiri, W R; Sauer-Budge, A F; Lee, J C; Klapperich, C M; Ziegler, L D

    2012-06-01

    There is a continuing need to develop new techniques for the rapid and specific identification of bacterial pathogens in human body fluids especially given the increasing prevalence of drug resistant strains. Efforts to develop a surface enhanced Raman spectroscopy (SERS) based approach, which encompasses sample preparation, SERS substrates, portable Raman microscopy instrumentation and novel identification software, are described. The progress made in each of these areas in our laboratory is summarized and illustrated by a spiked infectious sample for urinary tract infection (UTI) diagnostics. SERS bacterial spectra exhibit both enhanced sensitivity and specificity allowing the development of an easy to use, portable, optical platform for pathogen detection and identification. SERS of bacterial cells is shown to offer not only reproducible molecular spectroscopic signatures for analytical applications in clinical diagnostics, but also is a new tool for studying biochemical activity in real time at the outer layers of these organisms.

  8. Test Accuracy of Informant-Based Cognitive Screening Tests for Diagnosis of Dementia and Multidomain Cognitive Impairment in Stroke.

    PubMed

    McGovern, Aine; Pendlebury, Sarah T; Mishra, Nishant K; Fan, Yuhua; Quinn, Terence J

    2016-02-01

    Poststroke cognitive assessment can be performed using standardized questionnaires designed for family or care givers. We sought to describe the test accuracy of such informant-based assessments for diagnosis of dementia/multidomain cognitive impairment in stroke. We performed a systematic review using a sensitive search strategy across multidisciplinary electronic databases. We created summary test accuracy metrics and described reporting and quality using STARDdem and Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tools, respectively. From 1432 titles, we included 11 studies. Ten papers used the Informant Questionnaire on Cognitive Decline in the Elderly (IQCODE). Four studies described IQCODE for diagnosis of poststroke dementia (n=1197); summary sensitivity: 0.81 (95% confidence interval, 0.60-0.93); summary specificty: 0.83 (95% confidence interval, 0.64-0.93). Five studies described IQCODE as tool for predicting future dementia (n=837); summary sensitivity: 0.60 (95% confidence interval, 0.32-0.83); summary specificity: 0.97 (95% confidence interval, 0.70-1.00). All papers had issues with at least 1 aspect of study reporting or quality. There is a limited literature on informant cognitive assessments in stroke. IQCODE as a diagnostic tool has test properties similar to other screening tools, IQCODE as a prognostic tool is specific but insensitive. We found no papers describing test accuracy of informant tests for diagnosis of prestroke cognitive decline, few papers on poststroke dementia and all included papers had issues with potential bias. © 2015 American Heart Association, Inc.

  9. Use of machine learning to improve autism screening and diagnostic instruments: effectiveness, efficiency, and multi-instrument fusion

    PubMed Central

    Bone, Daniel; Bishop, Somer; Black, Matthew P.; Goodwin, Matthew S.; Lord, Catherine; Narayanan, Shrikanth S.

    2016-01-01

    Background Machine learning (ML) provides novel opportunities for human behavior research and clinical translation, yet its application can have noted pitfalls (Bone et al., 2015). In this work, we fastidiously utilize ML to derive autism spectrum disorder (ASD) instrument algorithms in an attempt to improve upon widely-used ASD screening and diagnostic tools. Methods The data consisted of Autism Diagnostic Interview-Revised (ADI-R) and Social Responsiveness Scale (SRS) scores for 1,264 verbal individuals with ASD and 462 verbal individuals with non-ASD developmental or psychiatric disorders (DD), split at age 10. Algorithms were created via a robust ML classifier, support vector machine (SVM), while targeting best-estimate clinical diagnosis of ASD vs. non-ASD. Parameter settings were tuned in multiple levels of cross-validation. Results The created algorithms were more effective (higher performing) than current algorithms, were tunable (sensitivity and specificity can be differentially weighted), and were more efficient (achieving near-peak performance with five or fewer codes). Results from ML-based fusion of ADI-R and SRS are reported. We present a screener algorithm for below (above) age 10 that reached 89.2% (86.7%) sensitivity and 59.0% (53.4%) specificity with only five behavioral codes. Conclusions ML is useful for creating robust, customizable instrument algorithms. In a unique dataset comprised of controls with other difficulties, our findings highlight limitations of current caregiver-report instruments and indicate possible avenues for improving ASD screening and diagnostic tools. PMID:27090613

  10. Use of machine learning to improve autism screening and diagnostic instruments: effectiveness, efficiency, and multi-instrument fusion.

    PubMed

    Bone, Daniel; Bishop, Somer L; Black, Matthew P; Goodwin, Matthew S; Lord, Catherine; Narayanan, Shrikanth S

    2016-08-01

    Machine learning (ML) provides novel opportunities for human behavior research and clinical translation, yet its application can have noted pitfalls (Bone et al., 2015). In this work, we fastidiously utilize ML to derive autism spectrum disorder (ASD) instrument algorithms in an attempt to improve upon widely used ASD screening and diagnostic tools. The data consisted of Autism Diagnostic Interview-Revised (ADI-R) and Social Responsiveness Scale (SRS) scores for 1,264 verbal individuals with ASD and 462 verbal individuals with non-ASD developmental or psychiatric disorders, split at age 10. Algorithms were created via a robust ML classifier, support vector machine, while targeting best-estimate clinical diagnosis of ASD versus non-ASD. Parameter settings were tuned in multiple levels of cross-validation. The created algorithms were more effective (higher performing) than the current algorithms, were tunable (sensitivity and specificity can be differentially weighted), and were more efficient (achieving near-peak performance with five or fewer codes). Results from ML-based fusion of ADI-R and SRS are reported. We present a screener algorithm for below (above) age 10 that reached 89.2% (86.7%) sensitivity and 59.0% (53.4%) specificity with only five behavioral codes. ML is useful for creating robust, customizable instrument algorithms. In a unique dataset comprised of controls with other difficulties, our findings highlight the limitations of current caregiver-report instruments and indicate possible avenues for improving ASD screening and diagnostic tools. © 2016 Association for Child and Adolescent Mental Health.

  11. Investigation of cAMP microdomains as a path to novel cancer diagnostics.

    PubMed

    Desman, Garrett; Waintraub, Caren; Zippin, Jonathan H

    2014-12-01

    Understanding of cAMP signaling has greatly improved over the past decade. The advent of live cell imaging techniques and more specific pharmacologic modulators has led to an improved understanding of the intricacies by which cAMP is able to modulate such a wide variety of cellular pathways. It is now appreciated that cAMP is able to activate multiple effector proteins at distinct areas in the cell leading to the activation of very different downstream targets. The investigation of signaling proteins in cancer is a common route to the development of diagnostic tools, prognostic tools, and/or therapeutic targets, and in this review we highlight how investigation of cAMP signaling microdomains driven by the soluble adenylyl cyclase in different cancers has led to the development of a novel cancer biomarker. Antibodies directed against the soluble adenylyl cyclase (sAC) are highly specific markers for melanoma especially for lentigo maligna melanoma and are being described as "second generation" cancer diagnostics, which are diagnostics that determine the 'state' of a cell and not just identify the cell type. Due to the wide presence of cAMP signaling pathways in cancer, we predict that further investigation of both sAC and other cAMP microdomains will lead to additional cancer biomarkers. This article is part of a Special Issue entitled: The role of soluble adenylyl cyclase in health and disease. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Diagnostic value of soluble triggering receptor expressed on myeloid cells in paediatric sepsis: a systematic review.

    PubMed

    Pontrelli, Giuseppe; De Crescenzo, Franco; Buzzetti, Roberto; Calò Carducci, Francesca; Jenkner, Alessandro; Amodio, Donato; De Luca, Maia; Chiurchiù, Sara; Davies, Elin Haf; Simonetti, Alessandra; Ferretti, Elena; Della Corte, Martina; Gramatica, Luca; Livadiotti, Susanna; Rossi, Paolo

    2016-04-27

    Differential diagnosis between sepsis and non-infectious inflammatory disorders demands improved biomarkers. Soluble Triggering Receptor Expression on Myeloid cells (sTREM-1) is an activating receptor whose role has been studied throughout the last decade. We performed a systematic review to evaluate the accuracy of plasma sTREM-1 levels in the diagnosis of sepsis in children with Systemic Inflammatory Response Syndrome (SIRS). A literature search of PubMed, Cochrane Central Register of Controlled Trials, Cumulative Index to Nursing and Allied Health Literature (CINAHL) and ISI Web of Knowledge databases was performed using specific search terms. Studies were included if they assessed the diagnostic accuracy of plasma sTREM-1 for sepsis in paediatric patients with SIRS. Data on sensitivity, specificity, positive predictive value, negative predictive value, area under receiver operating characteristic curve were extracted. The methodological quality of each study was assessed using a checklist based on the Quality Assessment Tool for Diagnostic Accuracy Studies. Nine studies comprising 961 patients were included, four of which were in newborns, three in children and two in children with febrile neutropenia. Some data from single studies support a role of sTREM-1 as a diagnostic tool in pediatric sepsis, but cannot be considered conclusive, because a quantitative synthesis was not possible, due to heterogeneity in studies design. This systematic review suggests that available data are insufficient to support a role for sTREM in the diagnosis and follow-up of paediatric sepsis.

  13. Application of Heart Rate Variability in Diagnosis and Prognosis of Individuals with Diabetes Mellitus: Systematic Review.

    PubMed

    França da Silva, Anne Kastelianne; Penachini da Costa de Rezende Barbosa, Marianne; Marques Vanderlei, Franciele; Destro Christofaro, Diego Giuliano; Marques Vanderlei, Luiz Carlos

    2016-05-01

    The use of heart rate variability as a tool capable of discriminating individuals with diabetes mellitus is still little explored, as its use has been limited to comparing those with and without the disease. Thus, the purpose of this study was to verify the use of heart rate variability as a tool for diagnostic and prognostic evaluation in person with diabetes and to identify whether there are cutoff points generated from the use of this tool in these individuals. A search was conducted in the electronic databases MEDLINE, Cochrane Library, Web of Science, EMBASE, and LILACS starting from the oldest records until January 2015, by means of descriptors related to the target condition, evaluated tool, and evaluation method. All the studies were evaluated for methodological quality using the QUADAS-2 instrument. Eight studies were selected. In general, the studies showed that the heart rate variability is useful to discriminate cardiac autonomic neuropathy in person with diabetes, and the sample entropy, SD1/SD2 indices, SDANN, HF, and slope of TFC have better discriminatory power to detect autonomic dysfunction, with sensitivity and specificity values ranging from 72% to 100% and 71% to 97%, respectively. Although there are methodological differences in indices used, in general, this tool demonstrated good sensitivity and specificity and can be used as an additional and/or complementary tool to the conventional autonomic tests, in order to obtain safer and more effective diagnostic, collaborating for better risk stratification conditions of these patients. © 2016 Wiley Periodicals, Inc.

  14. A Data-Driven Framework for Incorporating New Tools for ...

    EPA Pesticide Factsheets

    This talk was given during the “Exposure-Based Toxicity Testing” session at the annual meeting of the International Society for Exposure Science. It provided an update on the state of the science and tools that may be employed in risk-based prioritization efforts. It outlined knowledge gained from the data provided using these high-throughput tools to assess chemical bioactivity and to predict chemical exposures and also identified future needs. It provided an opportunity to showcase ongoing research efforts within the National Exposure Research Laboratory and the National Center for Computational Toxicology within the Office of Research and Development to an international audience. The National Exposure Research Laboratory (NERL) Computational Exposure Division (CED) develops and evaluates data, decision-support tools, and models to be applied to media-specific or receptor-specific problem areas. CED uses modeling-based approaches to characterize exposures, evaluate fate and transport, and support environmental diagnostics/forensics with input from multiple data sources. It also develops media- and receptor-specific models, process models, and decision support tools for use both within and outside of EPA.

  15. INCLEN diagnostic tool for attention deficit hyperactivity disorder (INDT-ADHD): development and validation.

    PubMed

    Mukherjee, Sharmila; Aneja, Satinder; Russell, Paul S S; Gulati, Sheffali; Deshmukh, Vaishali; Sagar, Rajesh; Silberberg, Donald; Bhutani, Vinod K; Pinto, Jennifer M; Durkin, Maureen; Pandey, Ravindra M; Nair, M K C; Arora, Narendra K

    2014-06-01

    To develop and validate INCLEN Diagnostic Tool for Attention Deficit Hyperactivity Disorder (INDT-ADHD). Diagnostic test evaluation by cross sectional design. Tertiary care pediatric centers. 156 children aged 65-117 months. After randomization, INDT-ADHD and Connors 3 Parent Rating Scale (C3PS) were administered, followed by an expert evaluation by DSM-IV-TR diagnostic criteria. Psychometric evaluation of diagnostic accuracy, validity (construct, criterion and convergent) and internal consistency. INDT-ADHD had 18 items that quantified symptoms and impairment. Attention deficit hyperactivity disorder was identified in 57, 87 and 116 children by expert evaluation, INDT-ADHD and C3PS, respectively. Psychometric parameters of INDT-ADHD for differentiating attention deficit hyperactivity disorder and normal children were: sensitivity 87.7%, specificity 97.2%, positive predictive value 98.0% and negative predictive value 83.3%, whereas for differentiating from other neuro-developmental disorders were 87.7%, 42.9%, 58.1% and 79.4%, respectively. Internal consistency was 0.91. INDT-ADHD has a 4-factor structure explaining 60.4% of the variance. Convergent validity with Conner's Parents Rating Scale was moderate (r =0.73, P= 0.001). INDT-ADHD is suitable for diagnosing attention deficit hyperactivity disorder in Indian children between the ages of 6 to 9 years.

  16. Diagnosis of TIA (DOT) score--design and validation of a new clinical diagnostic tool for transient ischaemic attack.

    PubMed

    Dutta, Dipankar

    2016-02-09

    The diagnosis of Transient Ischaemic Attack (TIA) can be difficult and 50-60% of patients seen in TIA clinics turn out to be mimics. Many of these mimics have high ABCD2 scores and fill urgent TIA clinic slots inappropriately. A TIA diagnostic tool may help non-specialists make the diagnosis with greater accuracy and improve TIA clinic triage. The only available diagnostic score (Dawson et al) is limited in scope and not widely used. The Diagnosis of TIA (DOT) Score is a new and internally validated web and mobile app based diagnostic tool which encompasses both brain and retinal TIA. The score was derived retrospectively from a single centre TIA clinic database using stepwise logistic regression by backwards elimination to find the best model. An optimum cutpoint was obtained for the score. The derivation and validation cohorts were separate samples drawn from the years 2010/12 and 2013 respectively. Receiver Operating Characteristic (ROC) curves and area under the curve (AUC) were calculated and the diagnostic accuracy of DOT was compared to the Dawson score. A web and smartphone calculator were designed subsequently. The derivation cohort had 879 patients and the validation cohort 525. The final model had seventeen predictors and had an AUC of 0.91 (95% CI: 0.89-0.93). When tested on the validation cohort, the AUC for DOTS was 0.89 (0.86-0.92) while that of the Dawson score was 0.77 (0.73-0.81). The sensitivity and specificity of the DOT score were 89% (CI: 84%-93%) and 76% (70%-81%) respectively while those of the Dawson score were 83% (78%-88%) and 51% (45%-57%). Other diagnostic accuracy measures (DOT vs. Dawson) include positive predictive values (75% vs. 58%), negative predictive values (89% vs. 79%), positive likelihood ratios (3.67 vs. 1.70) and negative likelihood ratios (0.15 vs. 0.32). The DOT score shows promise as a diagnostic tool for TIA and requires independent external validation before it can be widely used. It could potentially improve the triage of patients assessed for suspected TIA.

  17. Intraoral ultrasonography: development of a specific high-frequency probe and clinical pilot study.

    PubMed

    Salmon, Benjamin; Le Denmat, Dominique

    2012-04-01

    Although ultrasonography is a non-invasive, inexpensive and painless diagnostic tool for soft tissue imaging, this technique is not currently used for oral exploration. Therefore, we developed a 25-MHz high-frequency ultrasound probe, specially designed for intraoral applications. This paper aims to present clinical intraoral ultrasound images actually interpretable, in order to identify the relevant applications of this novel tool and to design future oral studies. Two independent radiologists performed ultrasound examinations on three healthy volunteers. All the teeth were explored on the lingual and buccal sides (162 samples) to evaluate the ergonomics of the system and the visualisation of anatomic structures. Osseointegrated dental implants and a mucocele were also scanned. At the gingivodental junction of the maxillary and mandibular teeth, the device clearly identifies the tooth surfaces, the alveolar bone reflection with its surrounding subepithelial connective tissue of the gingiva and the gingival epithelia. The bone level and the thickness of soft tissue around the implant are measurable on the buccal and lingual sides. Therefore, intraoral ultrasonography provides additional morphological information that is not accessible by conventional dental x-rays. We propose a novel diagnostic tool that explores the biological width and is able to define the thin or thick nature of the gums. Moreover, intraoral ultrasonography may help to monitor precancerous lesions. This promising device requires large-scale clinical studies to determine whether it should remain a research tool or be used as a diagnostic tool for daily dental practice.

  18. Case finding of lifestyle and mental health disorders in primary care: validation of the ‘CHAT’ tool

    PubMed Central

    Goodyear-Smith, Felicity; Coupe, Nicole M; Arroll, Bruce; Elley, C Raina; Sullivan, Sean; McGill, Anne-Thea

    2008-01-01

    Background Primary care is accessible and ideally placed for case finding of patients with lifestyle and mental health risk factors and subsequent intervention. The short self-administered Case-finding and Help Assessment Tool (CHAT) was developed for lifestyle and mental health assessment of adult patients in primary health care. This tool checks for tobacco use, alcohol and other drug misuse, problem gambling, depression, anxiety and stress, abuse, anger problems, inactivity, and eating disorders. It is well accepted by patients, GPs and nurses. Aim To assess criterion-based validity of CHAT against a composite gold standard. Design of study Conducted according to the Standards for Reporting of Diagnostic Accuracy statement for diagnostic tests. Setting Primary care practices in Auckland, New Zealand. Method One thousand consecutive adult patients completed CHAT and a composite gold standard. Sensitivities, specificities, positive and negative predictive values, and likelihood ratios were calculated. Results Response rates for each item ranged from 79.6 to 99.8%. CHAT was sensitive and specific for almost all issues screened, except exercise and eating disorders. Sensitivity ranged from 96% (95% confidence interval [CI] = 87 to 99%) for major depression to 26% (95% CI = 22 to 30%) for exercise. Specificity ranged from 97% (95% CI = 96 to 98%) for problem gambling and problem drug use to 40% (95% CI = 36 to 45%) for exercise. All had high likelihood ratios (3–30), except exercise and eating disorders. Conclusion CHAT is a valid and acceptable case-finding tool for most common lifestyle and mental health conditions. PMID:18186993

  19. Aptamers: novel diagnostic and therapeutic tools for diabetes mellitus and metabolic diseases.

    PubMed

    Hu, Jingping; Ye, Mao; Zhou, Zhiguang

    2017-03-01

    Diabetes mellitus is one of the most common chronic diseases that threatens human health in worldwide populations. Despite enormous efforts invested in the study of diabetes mellitus, the development of precise diagnoses and treatments for this disease remains difficult due to the limitations of current techniques. Therefore, new methods are currently being developed. Aptamers are oligonucleotides that bind to specific target molecules and have been widely applied as diagnostic and therapeutic tools. In recent years, aptamers have been utilized in the study of diabetes mellitus and metabolic diseases. In this review, we highlight recent developments and new perspectives on aptamers in the field of diabetes mellitus and other metabolic diseases. Aptamers could potentially provide the means for efficient diagnoses and therapies against diabetes mellitus.

  20. Investigation of an Error Theory for Conjoint Measurement Methodology.

    DTIC Science & Technology

    1983-05-01

    1ybren, 1982; Srinivasan and Shocker, 1973a, 1973b; Ullrich =d Cumins , 1973; Takane, Young, and de Leeui, 190C; Yount,, 1972’. & OEM...procedures as a diagnostic tool. Specifically, they used the oompted STRESS - value and a measure of fit they called PRECAP that could be obtained

  1. Strategies for Teaching Fractions: Using Error Analysis for Intervention and Assessment

    ERIC Educational Resources Information Center

    Spangler, David B.

    2011-01-01

    Many students struggle with fractions and must understand them before learning higher-level math. Veteran educator David B. Spangler provides research-based tools that are aligned with NCTM and Common Core State Standards. He outlines powerful diagnostic methods for analyzing student work and providing timely, specific, and meaningful…

  2. Use of Classification Agreement Analyses to Evaluate RTI Implementation

    ERIC Educational Resources Information Center

    VanDerHeyden, Amanda

    2010-01-01

    RTI as a framework for decision making has implications for the diagnosis of specific learning disabilities. Any diagnostic tool must meet certain standards to demonstrate that its use leads to predictable decisions with minimal risk. Classification agreement analyses are described as optimal for demonstrating the technical adequacy of RTI…

  3. Assessment of OmpATb as a Novel Antigen for the Diagnosis of Bovine Tuberculosis

    USDA-ARS?s Scientific Manuscript database

    In search for better tools to control bovine tuberculosis, the development of diagnostic tests with improved specificity and sensitivity has a high priority. We chose to search for novel immunodiagnostic reagents. In this study, Rv0899 (Outer membrane protein A of Mycobacterium tuberculosis, OmpATb)...

  4. Pieces of the Puzzle: Tracking the Chemical Component of the ...

    EPA Pesticide Factsheets

    This presentation provides an overview of the risk assessment conducted at the U.S. EPA, as well as some research examples related to the exposome concept. This presentation also provides the recommendation of using two organizational and predictive frameworks for tracking chemical components in the exposome. The National Exposure Research Laboratory (NERL) Computational Exposure Division (CED) develops and evaluates data, decision-support tools, and models to be applied to media-specific or receptor-specific problem areas. CED uses modeling-based approaches to characterize exposures, evaluate fate and transport, and support environmental diagnostics/forensics with input from multiple data sources. It also develops media- and receptor-specific models, process models, and decision support tools for use both within and outside of EPA.

  5. The Air Quality Model Evaluation International Initiative ...

    EPA Pesticide Factsheets

    This presentation provides an overview of the Air Quality Model Evaluation International Initiative (AQMEII). It contains a synopsis of the three phases of AQMEII, including objectives, logistics, and timelines. It also provides a number of examples of analyses conducted through AQMEII with a particular focus on past and future analyses of deposition. The National Exposure Research Laboratory (NERL) Computational Exposure Division (CED) develops and evaluates data, decision-support tools, and models to be applied to media-specific or receptor-specific problem areas. CED uses modeling-based approaches to characterize exposures, evaluate fate and transport, and support environmental diagnostics/forensics with input from multiple data sources. It also develops media- and receptor-specific models, process models, and decision support tools for use both within and outside of EPA.

  6. Research Priorities in the Utilization and Interpretation of Diagnostic Imaging: Education, Assessment, and Competency.

    PubMed

    Lewiss, Resa E; Chan, Wilma; Sheng, Alexander Y; Soto, Jorge; Castro, Alexandra; Meltzer, Andrew C; Cherney, Alan; Kumaravel, Manickam; Cody, Dianna; Chen, Esther H

    2015-12-01

    The appropriate selection and accurate interpretation of diagnostic imaging is a crucial skill for emergency practitioners. To date, the majority of the published literature and research on competency assessment comes from the subspecialty of point-of-care ultrasound. A group of radiologists, physicists, and emergency physicians convened at the 2015 Academic Emergency Medicine consensus conference to discuss and prioritize a research agenda related to education, assessment, and competency in ordering and interpreting diagnostic imaging. A set of questions for the continued development of an educational curriculum on diagnostic imaging for trainees and competency assessment using specific assessment methods based on current best practices was delineated. The research priorities were developed through an iterative consensus-driven process using a modified nominal group technique that culminated in an in-person breakout session. The four recommendations are: 1) develop a diagnostic imaging curriculum for emergency medicine (EM) residency training; 2) develop, study, and validate tools to assess competency in diagnostic imaging interpretation; 3) evaluate the role of simulation in education, assessment, and competency measures for diagnostic imaging; 4) study is needed regarding the American College of Radiology Appropriateness Criteria, an evidence-based peer-reviewed resource in determining the use of diagnostic imaging, to maximize its value in EM. In this article, the authors review the supporting reliability and validity evidence and make specific recommendations for future research on the education, competency, and assessment of learning diagnostic imaging. © 2015 by the Society for Academic Emergency Medicine.

  7. The Rapid-Heat LAMPellet Method: A Potential Diagnostic Method for Human Urogenital Schistosomiasis

    PubMed Central

    Carranza-Rodríguez, Cristina; Pérez-Arellano, José Luis; Vicente, Belén; López-Abán, Julio; Muro, Antonio

    2015-01-01

    Background Urogenital schistosomiasis due to Schistosoma haematobium is a serious underestimated public health problem affecting 112 million people - particularly in sub-Saharan Africa. Microscopic examination of urine samples to detect parasite eggs still remains as definitive diagnosis. This work was focussed on developing a novel loop-mediated isothermal amplification (LAMP) assay for detection of S. haematobium DNA in human urine samples as a high-throughput, simple, accurate and affordable diagnostic tool to use in diagnosis of urogenital schistosomiasis. Methodology/Principal Findings A LAMP assay targeting a species specific sequence of S. haematobium ribosomal intergenic spacer was designed. The effectiveness of our LAMP was assessed in a number of patients´ urine samples with microscopy confirmed S. haematobium infection. For potentially large-scale application in field conditions, different DNA extraction methods, including a commercial kit, a modified NaOH extraction method and a rapid heating method were tested using small volumes of urine fractions (whole urine, supernatants and pellets). The heating of pellets from clinical samples was the most efficient method to obtain good-quality DNA detectable by LAMP. The detection limit of our LAMP was 1 fg/µL of S. haematobium DNA in urine samples. When testing all patients´ urine samples included in our study, diagnostic parameters for sensitivity and specificity were calculated for LAMP assay, 100% sensitivity (95% CI: 81.32%-100%) and 86.67% specificity (95% CI: 75.40%-94.05%), and also for microscopy detection of eggs in urine samples, 69.23% sensitivity (95% CI: 48.21% -85.63%) and 100% specificity (95% CI: 93.08%-100%). Conclusions/Significance We have developed and evaluated, for the first time, a LAMP assay for detection of S. haematobium DNA in heated pellets from patients´ urine samples using no complicated requirement procedure for DNA extraction. The procedure has been named the Rapid-Heat LAMPellet method and has the potential to be developed further as a field diagnostic tool for use in urogenital schistosomiasis-endemic areas. PMID:26230990

  8. Efficiency of the Bethesda System for Thyroid Cytopathology.

    PubMed

    Mora-Guzmán, Ismael; Muñoz de Nova, José Luis; Marín-Campos, Cristina; Jiménez-Heffernan, José Antonio; Cuesta Pérez, Juan Julián; Lahera Vargas, Marcos; Torres Mínguez, Emma; Martín-Pérez, Elena

    2018-03-28

    Fine-needle aspiration biopsies are a key tool for preoperative assessment of thyroid nodules, and the Bethesda system is the preferred method to report cytological analysis. The purpose of this study is to assess the efficiency of the Bethesda system to identify the malignancy risk of thyroid nodules. Patients who underwent thyroid surgery between June 2010 and June 2017 were included. Samples were classified into 6categories according to rates of malignancy associated with each diagnostic category. In order to investigate the correlation between categories, a statistical analysis compared the categories with pathology reports. Diagnostic indicators were calculated as a screening test (categories IV, V, VI as true-positive) and as a method to identify malignancy (V, VI as true-positive). In a series of 522 patients, we found 184 (35.2%) malignant tumours, papillary carcinoma being the most prevalent with 155 cases (84.2%). Malignant rates for diagnostic categories were: I, 0%; II, 1.5%; III, 6.4%; IV, 31%; V, 86.5%; VI, 100%. A robust correlation was identified between categories on statistical analysis. For the «screening test» analysis, sensitivity was 98.9%, specificity 84.4%, positive predictive value 69.6%, negative predictive value 99.5%, and diagnostic accuracy 88.2%. Analysing the accuracy to detect malignancy, values were: sensitivity 98.6%, specificity 97.6%, positive predictive value 93.5%, negative predictive value 99.5%, diagnostic accuracy 97.9%. The Bethesda system is a clear and reliable approach to report thyroid cytology and therefore is an effective tool to identify malignancy risk and guide clinical management. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Intraoral fiber optic-based diagnostic for periodontal disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, P W; Gutierrez, D M; Everett, M J

    2000-01-21

    The purpose of this initial study was to begin development of a new, objective diagnostic instrument that will allow simultaneous quantitation of multiple proteases within a single periodontal pocket using a chemical fiber optic sensor. This approach could potentially be adapted to use specific antibodies and chemiluminescence to detect and quantitate virtually any compound and compare concentrations of different compounds within the same periodontal pocket. The device could also be used to assay secretions in salivary ducts or from a variety of wounds. The applicability is, therefore, not solely limited to dentistry and the device would be important both formore » clinical diagnostics and as a research tool.« less

  10. Lichtheimia Infection in a Lymphoma Patient: Case Report and a Brief Review of the Available Diagnostic Tools.

    PubMed

    Zimmerli, Stefan; Bialek, Ralf; Blau, Igor W; Christe, Andreas; Lass-Flörl, Cornelia; Presterl, Elisabeth

    2016-08-01

    We describe the case of a patient with a T-lymphoblastic lymphoma whose disseminated mucormycosis was diagnosed with delay, and we address the diagnostic and therapeutic decision-making process and review the diagnostic workup of patients with potential IFD. The diagnosis was delayed despite a suggestive radiological presentation of the patient's pulmonary lesion. The uncommon risk profile (T-lymphoblastic lymphoma, short neutropenic phases) wrongly led to a low level of suspicion. The diagnosis was also hampered by the lack of indirect markers for infections caused by Mucorales, the low sensitivity of both fungal culture and panfungal PCR, and the limited availability of species-specific PCR. A high level of suspicion of IFD is needed, and aggressive diagnostic procedures should be promptly initiated even in apparently low-risk patients with uncommon presentations. The extent of the analytical workup should be decided on a case-by-case base. Diagnostic tests such as the galactomannan and β-D-glucan test and/or PCR on biological material followed by sequencing should be chosen according to their availability and after evaluation of their specificity and sensitivity. In high-risk patients, preemptive therapy with a broad-spectrum mould-active antifungal agent should be started before definitive diagnostic findings become available.

  11. Diagnostic performance of 64-slice multidetector coronary computed tomographic angiography in women.

    PubMed

    Jug, Borut; Gupta, Mohit; Papazian, Jenny; Li, Dong; Tsang, Janet; Bhatia, Harpreet; Karlsberg, Ronald; Budoff, Matthew

    2012-12-01

    Diagnostic approach to chest pain in women is challenging, but still under-investigated. The purpose of this study was to assess the diagnostic performance of 64-slice multidetector coronary computed tomographic angiography (CCTA) in women with chest pain. We included 606 patients--255 women and 351 men (mean age 61 ± 12 years for both)--who had been referred for a CCTA and an invasive coronary angiography (diagnostic standard) because of chest pain, either as part of clinical work-up in two urban medical centers or as part of the multicenter ACCURACY trial. On a patient-based model, the sensitivity, specificity, and positive predictive value (PPV) and negative predictive value to detect ≥50% and ≥70% stenosis were 98%, 84%, 87%, and 97% and 96%, 83%, 77%, and 97%, respectively, for women and 97%, 83%, 89%, and 95% and 94%, 91%, 90%, and 94%, respectively, for men. There were no statistically significant differences between men and women in diagnostic performance measures except for the PPV of detecting a ≥70% stenosis (P = .007). In women with chest pain, 64-slice multidetector CCTA is at least as sensitive and specific as in men. Our findings suggest that CCTA is a promising diagnostic tool for timely detection and/or exclusion of CAD in symptomatic intermediate-risk female populations.

  12. Multiplex PCR Tests for Detection of Pathogens Associated with Gastroenteritis

    PubMed Central

    Zhang, Hongwei; Morrison, Scott; Tang, Yi-Wei

    2016-01-01

    Synopsis A wide range of enteric pathogens can cause infectious gastroenteritis. Conventional diagnostic algorithms including culture, biochemical identification, immunoassay and microscopic examination are time consuming and often lack sensitivity and specificity. Advances in molecular technology have as allowed its use as clinical diagnostic tools. Multiplex PCR based testing has made its way to gastroenterology diagnostic arena in recent years. In this article we present a review of recent laboratory developed multiplex PCR tests and current commercial multiplex gastrointestinal pathogen tests. We will focus on two FDA cleared commercial syndromic multiplex tests: Luminex xTAG GPP and Biofire FimArray GI test. These multiplex tests can detect and identify multiple enteric pathogens in one test and provide results within hours. Multiplex PCR tests have shown superior sensitivity to conventional methods for detection of most pathogens. The high negative predictive value of these multiplex tests has led to the suggestion that they be used as screening tools especially in outbreaks. Although the clinical utility and benefit of multiplex PCR test are to be further investigated, implementing these multiplex PCR tests in gastroenterology diagnostic algorithm has the potential to improve diagnosis of infectious gastroenteritis. PMID:26004652

  13. Problem Representation, Background Evidence, Analysis, Recommendation: An Oral Case Presentation Tool to Promote Diagnostic Reasoning.

    PubMed

    Carter, Cristina; Akar-Ghibril, Nicole; Sestokas, Jeff; Dixon, Gabrina; Bradford, Wilhelmina; Ottolini, Mary

    2018-03-01

    Oral case presentations provide an opportunity for trainees to communicate diagnostic reasoning at the bedside. However, few tools exist to enable faculty to provide effective feedback. We developed a tool to assess diagnostic reasoning and communication during oral case presentations. Published by Elsevier Inc.

  14. The diagnostic value of the premature ejaculation diagnostic tool and its association with intravaginal ejaculatory latency time.

    PubMed

    Kam, Sung Chul; Han, Deok Hyun; Lee, Sung Won

    2011-03-01

    Premature ejaculation (PE) is the most prevalent male ejaculation disorder. The premature ejaculation diagnostic tool (PEDT) was developed to systematically apply the DSM-IV-TR criteria in diagnostic PE. To evaluate the diagnostic value of the PEDT and its association with intravaginal ejaculatory latency time (IELT). (i) Korean validation of PEDT: data was collected from men interviewed by one of the two clinical experts, who made a diagnostic of present or absence of PE, using DSM-IV-TR criteria. A total of 103 patients with PE and 100 men without PE were enrolled into the study and requested to complete the PEDT; and (ii) The correlation between IELT and PEDT: 200 participants were enrolled and each participant was asked to make out PEDT. All participants were requested to measure IELT. Validity and reliability of the PEDT and its association with IELT. The geometric mean IELT of the PE group was 115.37 ± 78.14 seconds. The number of men reporting IELTs of <1, 1 to ≤ 2, and >2 minutes were 28 (28.6%), 29 (29.6%), and 41 (41.8%), respectively. The Cronbach's alpha score was calculated as 0.93, showing adequate internal consistency. The test-retest correlation coefficients of each item were higher than 0.72 and the correlation coefficients of the total score was 0.88. (P < 0.001) Sensitivity and specificity analyses suggested a score of ≤ 8 indicated no PE, 9 and 10 probable PE, and ≥ 11 PE. The PEDT total score and IELT showed an adequate negative correlation. (ρ = -0.77, P < 0.0001) also, the PEDT total score of the PE subgroup (IELT ≤ 2 minutes) and IELT showed a negative correlation. (ρ = -0.6, P < 0.0001) The PEDT was highly effective in detecting the presence of PE. The result of our study supports its validity as a diagnostic tool in the clinical setting. © 2010 International Society for Sexual Medicine.

  15. Development and evaluation of a Loop Mediated Isothermal Amplification (LAMP) technique for the detection of hookworm (Necator americanus) infection in fecal samples.

    PubMed

    Mugambi, Robert Muriuki; Agola, Eric L; Mwangi, Ibrahim N; Kinyua, Johnson; Shiraho, Esther Andia; Mkoji, Gerald M

    2015-11-06

    Hookworm infection is a major concern in sub-Saharan Africa, particularly in children and pregnant women. Necator americanus and Ancylostoma duodenale are responsible for this condition. Hookworm disease is one of the Neglected tropical diseases (NTDs) that are targeted for elimination through global mass chemotherapy. To support this there is a need for reliable diagnostic tools. The conventional diagnostic test, Kato-Katz that is based on microscopic detection of parasite ova in faecal samples, is not effective due to its low sensitivity that is brought about mainly by non-random distribution of eggs in stool and day to day variation in egg output. It is tedious, cumbersome to perform and requires experience for correct diagnosis. LAMP-based tests are simple, relatively cheap, offer greater sensitivity, specificity than existing tests, have high throughput capability, and are ideal for use at the point of care. We have developed a LAMP diagnostic test for detection of hookworm infection in faecal samples. LAMP relies on auto cycling strand displacement DNA synthesis performed at isothermal temperature by Bst polymerase and a set of 4 specific primers. The primers used in the LAMP assay were based on the second Internal Transcribed Spacer (ITS-2) region and designed using Primer Explorer version 4 Software. The ITS-2 region of the ribosomal gene (rDNA) was identified as a suitable target due to its low mutation rates and substantial differences between species. DNA was extracted directly from human faecal samples, followed by LAMP amplification at isothermal temperature of 63 °C for 1 h. Amplicons were visualized using gel electrophoresis and SYBR green dye. Both specificity and sensitivity of the assay were determined. The LAMP based technique developed was able to detect N. americanus DNA in faecal samples. The assay showed 100 % specificity and no cross-reaction was observed with other helminth parasites (S. mansoni, A. lumbricoides or T. trichiura). The developed LAMP assay was 97 % sensitive and DNA at concentrations as low as 0.4 fg were amplified. The LAMP assay developed is an appropriate diagnostic method for the detection of N. americanus DNA in human stool samples because of its simplicity, low cost, sensitivity, and specificity. It holds great promise as a useful diagnostic tool for use in disease control where infection intensities have been significantly reduced.

  16. Prevalence of PCR detectable malaria infection among febrile patients with a negative Plasmodium falciparum specific rapid diagnostic test in Zanzibar.

    PubMed

    Baltzell, Kimberly A; Shakely, Deler; Hsiang, Michelle; Kemere, Jordan; Ali, Abdullah Suleiman; Björkman, Anders; Mårtensson, Andreas; Omar, Rahila; Elfving, Kristina; Msellem, Mwinyi; Aydin-Schmidt, Berit; Rosenthal, Philip J; Greenhouse, Bryan

    2013-02-01

    We screened for malaria in 594 blood samples from febrile patients who tested negative by a Plasmodium falciparum-specific histidine-rich protein-2-based rapid diagnostic test at 12 health facilities in Zanzibar districts North A and Micheweni, from May to August 2010. Screening was with microscopy, polymerase chain reaction (PCR) targeting the cytochrome b gene (cytbPCR) of the four major human malaria species, and quantitative PCR (qPCR). The prevalence of cytbPCR-detectable malaria infection was 2% (12 of 594), including 8 P. falciparum, 3 Plasmodium malariae, and 1 Plasmodium vivax infections. Microscopy identified 4 of 8 P. falciparum infections. Parasite density as estimated by microscopy or qPCR was > 4,000 parasites/μL in 5 of 8 cytbPCR-detectable P. falciparum infections. The infections that were missed by the rapid diagnostic test represent a particular challenge in malaria elimination settings and highlight the need for more sensitive point-of-care diagnostic tools to improve case detection of all human malaria species in febrile patients.

  17. Hypersensitivity and desensitization to antineoplastic agents: outcomes of 189 procedures with a new short protocol and novel diagnostic tools assessment.

    PubMed

    Madrigal-Burgaleta, R; Berges-Gimeno, M P; Angel-Pereira, D; Ferreiro-Monteagudo, R; Guillen-Ponce, C; Pueyo, C; Gomez de Salazar, E; Alvarez-Cuesta, E

    2013-07-01

    Desensitization to antineoplastic agents is becoming a standard of care. Efforts to establish and improve these techniques are being made at many institutions. Our aims are to evaluate a new rapid desensitization protocol designed to be shorter (approximately 4 h) and safer (reducing hazardous drugs exposure risks) and to assess the oxaliplatin-specific immunoglobulin E (IgE) as a novel diagnostic tool. Prospective, observational, longitudinal study with patients who, for a 1-year period, suffered reactions to antineoplastic agents and were referred to the Desensitization Program at Ramon y Cajal University Hospital (RCUH). Patients were included or excluded as desensitization candidates after anamnesis, skin testing, risk assessment, and graded challenge. Specific IgE was determined in oxaliplatin-reactive patients. Candidate patients were desensitized using the new RCUH rapid desensitization protocol. Of 189 intravenous rapid desensitizations, 188 were successfully accomplished in the 23 patients who met inclusion criteria for desensitization (of 58 referred patients). No breakthrough reactions occurred in 94% of desensitizations, and most breakthrough reactions were mild. In 10 oxaliplatin-reactive patients, 38 desensitizations were successfully accomplished. Sensitivity for oxaliplatin-specific IgE was 38% (0.35UI/l cutoff point) and 54% (0.10UI/l cutoff point); specificity was 100% for both cutoff points. In the hands of a Desensitization Program, managed by drug desensitization experts, this new protocol has proven an effective therapeutic tool for hypersensitivity to several antineoplastic agents (oxaliplatin, carboplatin, paclitaxel, docetaxel, cyclophosphamide, and rituximab); moreover, it improves safety handling of hazardous drugs. We report the first large series of oxaliplatin desensitizations. Oxaliplatin-specific IgE determination could be helpful. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Evaluating the diagnostic accuracy of the Xpert MTB/RIF assay on bronchoalveolar lavage fluid: A retrospective study.

    PubMed

    Lu, Yanjun; Zhu, Yaowu; Shen, Na; Tian, Lei; Sun, Ziyong

    2018-02-08

    Limited data on the diagnostic accuracy of the Xpert MTB/RIF assay using bronchoalveolar lavage fluid from patients with suspected pulmonary tuberculosis (PTB) have been reported in China. Therefore, a retrospective study was designed to evaluate the diagnostic accuracy of this assay. Clinical, radiological, and microbiological characteristics of 238 patients with suspected PTB were reviewed retrospectively. The sensitivity, specificity, positive predictive value, and negative predictive value for the diagnosis of active PTB were calculated for the Xpert MTB/RIF assay using TB culture or final diagnosis based on clinical and radiological evaluation as the reference standard. The sensitivity and specificity of the Xpert MTB/RIF assay were 84.5% and 98.9%, respectively, and those for smear microscopy were 36.2% and 100%, respectively, when compared to the culture method. However, compared with the sensitivity and specificity of final diagnosis based on clinical and radiological evaluation, the sensitivity and specificity of the assay were 72.9% and 98.7%, respectively, which were significantly higher than those for smear microscopy. The Xpert MTB/RIF assay on bronchoalveolar lavage fluid could serve as an additional rapid diagnostic tool for PTB in a high TB-burden country and improve the time to TB treatment initiation in patients with PTB. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  19. [The Revision and 5th Edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5): Consequences for the Diagnostic Work with Children and Adolescents].

    PubMed

    Zulauf Logoz, Marina

    2014-01-01

    The Revision and 5th Edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5): Consequences for the Diagnostic Work with Children and Adolescents.The present paper describes and discusses the major revisions in DSM-5 for children and adolescents. A major modification is that the separate chapter for disorders first diagnosed in childhood and adolescence was abandoned in favour of the integration of these clinical pictures into the relevant disorder-specific chapters. Several new diagnoses and diagnostic groups were introduced: "Disruptive mood regulation disorder" is a new diagnosis; the different diagnoses for autism were brought together into one, and a new diagnostic group for obsessive-compulsive disorders has been established. The developmental approach of DSM-5 and the integration of dimensional assessment tools are to be welcomed. Practice will show if the critiques afraid of possible increases in prevalences or those who approve the changes will end up being right.

  20. Volatile metabolomic signature of human breast cancer cell lines

    PubMed Central

    Silva, Catarina L.; Perestrelo, Rosa; Silva, Pedro; Tomás, Helena; Câmara, José S.

    2017-01-01

    Breast cancer (BC) remains the most prevalent oncologic pathology in women, causing huge psychological, economic and social impacts on our society. Currently, the available diagnostic tools have limited sensitivity and specificity. Metabolome analysis has emerged as a powerful tool for obtaining information about the biological processes that occur in organisms, and is a useful platform for discovering new biomarkers or make disease diagnosis using different biofluids. Volatile organic compounds (VOCs) from the headspace of cultured BC cells and normal human mammary epithelial cells, were collected by headspace solid-phase microextraction (HS-SPME) and analyzed by gas chromatography combined with mass spectrometry (GC–MS), thus defining a volatile metabolomic signature. 2-Pentanone, 2-heptanone, 3-methyl-3-buten-1-ol, ethyl acetate, ethyl propanoate and 2-methyl butanoate were detected only in cultured BC cell lines. Multivariate statistical methods were used to verify the volatomic differences between BC cell lines and normal cells in order to find a set of specific VOCs that could be associated with BC, providing comprehensive insight into VOCs as potential cancer biomarkers. The establishment of the volatile fingerprint of BC cell lines presents a powerful approach to find endogenous VOCs that could be used to improve the BC diagnostic tools and explore the associated metabolomic pathways. PMID:28256598

  1. [Effects of critical ultrasonic management of Peking Union Medical College Hospital on the etiological diagnosis of patients with acute respiratory failure].

    PubMed

    Zhao, Hua; Wang, Xiaoting; Liu, Dawei; Zhang, Hongmin; He, Huaiwu; Long, Yun

    2015-12-15

    To evaluate the diagnostic value and potential therapeutic impact of Peking Union Medical College Hospital critical ultrasonic management (PCUM) in the early management of critically ill patients with acute respiratory failure (ARF). Patients admitted into the ICU of Peking Union Medical College Hospital for ARF were consecutively recruited over a 18-month period. Patients were randomly divided into conventional group and PCUM group (critical care ultrasonic examination was added in addition to conventional examinations). The two groups were compared with respect to time to preliminary diagnosis, time to final diagnosis, diagnostic accuracy, time to treatment response, time to other examination. A total of 187 patients were included in this study. The two groups showed no significant differences in general clinical information or final diagnosis (P > 0.05). The PCUM group had a shorter time to preliminary diagnosis, time to final diagnosis, time to treatment response, time to X-ray/CT examination, and a higher diagnostic accuracy than the conventional group (P < 0.001). PCUM had high sensitivity and specificity for the diagnosis of acute respiratory distress syndrome (ARDS) (sensitivity 92.0%, specificity 98.5%), acute pulmonary edema (sensitivity 94.7%, specificity 96.1%), pulmonary consolidation (sensitivity 85.7%, specificity 98.6%), COPD/asthma (sensitivity 84.2%, specificity 98.7%). The PCUM is seem to be an attractive complementary diagnostic tool and able to contribute to an early therapeutic decision for the patients with ARF.

  2. Diagnostic and prognostic utility of an inexpensive rapid on site malaria diagnostic test (ParaHIT f) among ethnic tribal population in areas of high, low and no transmission in central India.

    PubMed

    Singh, Neeru; Mishra, A K; Shukla, M M; Chand, S K; Bharti, Praveen Kumar

    2005-06-21

    Malaria presents a diagnostic challenge in most tropical countries. Rapid detection of the malaria parasite and early treatment of infection still remain the most important goals of disease management. Therefore, performance characteristics of the new indigenous ParaHIT f test (Span diagnostic Ltd, Surat, India) was determined among ethnic tribal population in four districts of different transmission potential in central India to assess whether this rapid diagnostic test (RDT) could be widely applied as a diagnostic tool to control malaria. Beyond diagnosis, the logical utilization of RDTs is to monitor treatment outcome. A finger prick blood sample was collected from each clinically suspected case of malaria to prepare blood smear and for testing with the RDT after taking informed consent. The blood smears were read by an experienced technician blinded to the RDT results and clinical status of the subjects. The figures for specificity, sensitivity, accuracy and predictive values were calculated using microscopy as gold standard. The prevalence of malaria infection estimated by RDT in parallel with microscopy provide evidence of the type of high, low or no transmission in the study area. Analysis revealed (pooled data of all four epidemiological settings) that overall sensitivity, specificity and accuracy of the RDT were >90% in areas of different endemicity. While, RDT is useful to confirm the diagnosis of new symptomatic cases of suspected P. falciparum infection, the persistence of parasite antigen leading to false positives even after clearance of asexual parasitaemia has limited its utility as a prognostic tool. The study showed that the ParaHIT f test was easy to use, reliable and cheap. Thus this RDT is an appropriate test for the use in the field by paramedical staff when laboratory facilities are not available and thus likely to contribute greatly to an effective control of malaria in resource poor countries.

  3. Lung ultrasound in diagnosing pneumonia in childhood: a systematic review and meta-analysis.

    PubMed

    Orso, Daniele; Ban, Alessio; Guglielmo, Nicola

    2018-06-21

    Pneumonia is the third leading cause of death in children under 5 years of age worldwide. In pediatrics, both the accuracy and safety of diagnostic tools are important. Lung ultrasound (LUS) could be a safe diagnostic tool for this reason. We searched in the literature for diagnostic studies about LUS to predict pneumonia in pediatric patients using systematic review and meta-analysis. The Medline, CINAHL, Cochrane Library, Embase, SPORTDiscus, ScienceDirect, and Web of Science databases from inception to September 2017 were searched. All studies that evaluated the diagnostic accuracy of LUS in determining the presence of pneumonia in patients under 18 years of age were included. 1042 articles were found by systematic search. 76 articles were assessed for eligibility. Seventeen studies were included in the systematic review. We included 2612 pooled cases. The age of the pooled sample population ranged from 0 to about 21 years old. Summary sensitivity, specificity, and AUC were 0.94 (IQR: 0.89-0.97), 0.93 (IQR: 0.86-0.98), and 0.98 (IQR: 0.94-0.99), respectively. No agreement on reference standard was detected: nine studies used chest X-rays, while four studies considered the clinical diagnosis. Only one study used computed tomography. LUS seems to be a promise tool for diagnosing pneumonia in children. However, the high heterogeneity found across the individual studies, and the absence of a reliable reference standard, make the finding questionable. More methodologically rigorous studies are needed.

  4. Interactive visualisation for interpreting diagnostic test accuracy study results.

    PubMed

    Fanshawe, Thomas R; Power, Michael; Graziadio, Sara; Ordóñez-Mena, José M; Simpson, John; Allen, Joy

    2018-02-01

    Information about the performance of diagnostic tests is typically presented in the form of measures of test accuracy such as sensitivity and specificity. These measures may be difficult to translate directly into decisions about patient treatment, for which information presented in the form of probabilities of disease after a positive or a negative test result may be more useful. These probabilities depend on the prevalence of the disease, which is likely to vary between populations. This article aims to clarify the relationship between pre-test (prevalence) and post-test probabilities of disease, and presents two free, online interactive tools to illustrate this relationship. These tools allow probabilities of disease to be compared with decision thresholds above and below which different treatment decisions may be indicated. They are intended to help those involved in communicating information about diagnostic test performance and are likely to be of benefit when teaching these concepts. A substantive example is presented using C reactive protein as a diagnostic marker for bacterial infection in the older adult population. The tools may also be useful for manufacturers of clinical tests in planning product development, for authors of test evaluation studies to improve reporting and for users of test evaluations to facilitate interpretation and application of the results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. Next-generation confirmatory disease diagnostics

    NASA Astrophysics Data System (ADS)

    Lin, Robert; Gerver, Rachel; Karns, Kelly; Apori, Akwasi A.; Denisin, Aleksandra K.; Herr, Amy E.

    2014-06-01

    Microfluidic tools are advancing capabilities in screening diagnostics for use in near-patient settings. Here, we review three case studies to illustrate the flexibility and analytical power offered by microanalytical tools. We first overview a near-patient tool for detection of protein markers found in cerebrospinal fluid (CSF), as a means to identify the presence of cerebrospinal fluid in nasal mucous - an indication that CSF is leaking into the nasal cavity. Microfluidic design allowed integration of several up-stream preparatory steps and rapid, specific completion of the human CSF protein assay. Second, we overview a tear fluid based assay for lactoferrin, a protein produced in the lacrimal gland, then secreted into tear fluid. Tear Lf is a putative biomarker for primary SS. A critical contribution of this and related work being measurement of Lf, even in light of well-known and significant matrix interactions and losses during the tear fluid collection and preparation. Lastly, we review a microfluidic barcode platform that enables rapid measurement of multiple infectious disease biomarkers in human sera. The assay presents a new approach to multiplexed biomarker detection, yet in a simple straight microchannel - thus providing a streamlined, simplified microanalytical platform, as is relevant to robust operation in diagnostic settings. We view microfluidic design and analytical chemistry as the basis for emerging, sophisticated assays that will advance not just screening diagnostic technology, but confirmatory assays, sample preparation and handling, and thus introduction and utilization of new biomarkers and assay formats.

  6. Considerations for Test Selection: How Do Validity and Reliability Impact Diagnostic Decisions?

    ERIC Educational Resources Information Center

    Friberg, Jennifer C.

    2010-01-01

    Nine preschool and school-age language assessment tools found to have acceptable levels of identification accuracy were evaluated to determine their overall levels of psychometric validity for use in diagnosing the presence/absence of language impairment. Eleven specific criteria based on those initially devised by McCauley and Swisher (1984) were…

  7. Reliability and Validity of the SPAID-G Checklist for Detecting Psychiatric Disorders in Adults with Intellectual Disability

    ERIC Educational Resources Information Center

    Bertelli, Marco; Scuticchio, Daniela; Ferrandi, Angela, Lassi, Stefano; Mango, Francesco; Ciavatta, Claudio; Porcelli, Cesare; Bianco, Annamaria; Monchieri, Sergio

    2012-01-01

    SPAID (Psychiatric Instrument for the Intellectually Disabled Adult) is the first Italian tool-package for carrying out psychiatric diagnosis in adults with Intellectual Disabilities (ID). It includes the "G" form, for general diagnostic orientation, and specific checklists for all groups of syndromes stated by the available…

  8. Transcriptome amplification coupled with nanopore sequencing as a surveillance tool for plant pathogens in plant and insect tissues

    USDA-ARS?s Scientific Manuscript database

    There are many plant pathogen-specific diagnostic assays, based on PCR and immune-detection. However, the ability to test for large numbers of pathogens simultaneously is lacking. Next generation sequencing (NGS) allows one to detect all organisms within a given sample, but has computational limitat...

  9. Assessment of Mycobacterium tuberculosis OmpATb as a Novel Antigen for the Diagnosis of Bovine Tuberculosis

    USDA-ARS?s Scientific Manuscript database

    In search for improved tools to control bovine tuberculosis, the development of diagnostic tests with improved specificity and sensitivity has a high priority. Such tests require the identification of enhanced immunodiagnostic reagents. In this study, we evaluated the potential of Rv0899 (Outer memb...

  10. Analytical Utility of Mass Spectral Binning in Proteomic Experiments by SPectral Immonium Ion Detection (SPIID)*

    PubMed Central

    Kelstrup, Christian D.; Frese, Christian; Heck, Albert J. R.; Olsen, Jesper V.; Nielsen, Michael L.

    2014-01-01

    Unambiguous identification of tandem mass spectra is a cornerstone in mass-spectrometry-based proteomics. As the study of post-translational modifications (PTMs) by means of shotgun proteomics progresses in depth and coverage, the ability to correctly identify PTM-bearing peptides is essential, increasing the demand for advanced data interpretation. Several PTMs are known to generate unique fragment ions during tandem mass spectrometry, the so-called diagnostic ions, which unequivocally identify a given mass spectrum as related to a specific PTM. Although such ions offer tremendous analytical advantages, algorithms to decipher MS/MS spectra for the presence of diagnostic ions in an unbiased manner are currently lacking. Here, we present a systematic spectral-pattern-based approach for the discovery of diagnostic ions and new fragmentation mechanisms in shotgun proteomics datasets. The developed software tool is designed to analyze large sets of high-resolution peptide fragmentation spectra independent of the fragmentation method, instrument type, or protease employed. To benchmark the software tool, we analyzed large higher-energy collisional activation dissociation datasets of samples containing phosphorylation, ubiquitylation, SUMOylation, formylation, and lysine acetylation. Using the developed software tool, we were able to identify known diagnostic ions by comparing histograms of modified and unmodified peptide spectra. Because the investigated tandem mass spectra data were acquired with high mass accuracy, unambiguous interpretation and determination of the chemical composition for the majority of detected fragment ions was feasible. Collectively we present a freely available software tool that allows for comprehensive and automatic analysis of analogous product ions in tandem mass spectra and systematic mapping of fragmentation mechanisms related to common amino acids. PMID:24895383

  11. Structure and Computation in Immunoreagent Design: From Diagnostics to Vaccines.

    PubMed

    Gourlay, Louise; Peri, Claudio; Bolognesi, Martino; Colombo, Giorgio

    2017-12-01

    Novel immunological tools for efficient diagnosis and treatment of emerging infections are urgently required. Advances in the diagnostic and vaccine development fields are continuously progressing, with reverse vaccinology and structural vaccinology (SV) methods for antigen identification and structure-based antigen (re)design playing increasingly relevant roles. SV, in particular, is predicted to be the front-runner in the future development of diagnostics and vaccines targeting challenging diseases such as AIDS and cancer. We review state-of-the-art methodologies for structure-based epitope identification and antigen design, with specific applicative examples. We highlight the implications of such methods for the engineering of biomolecules with improved immunological properties, potential diagnostic and/or therapeutic uses, and discuss the perspectives of structure-based rational design for the production of advanced immunoreagents. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Aptahistochemistry in diagnostic pathology: technical scrutiny and feasibility.

    PubMed

    Bukari, Bakhtiar A; Citartan, Marimuthu; Ch'ng, Ewe Seng; Bilibana, Mawethu P; Rozhdestvensky, Timofey; Tang, Thean-Hock

    2017-05-01

    Antibodies have been the workhorse for diagnostic immunohistochemistry to specifically interrogate the expression of certain protein to aid in histopathological diagnosis. This review introduces another dimension of histochemistry that employs aptamers as the core tool, the so-called aptahistochemistry. Aptamers are an emerging class of molecular recognition elements that could recapitulate the roles of antibodies. The many advantageous properties of aptamers suited for this diagnostic platform are scrutinized. An in-depth discussion on the technical aspects of aptahistochemistry is provided with close step-by-step comparison to the more familiarized immunohistochemical procedures, namely functionalization of the aptamer as a probe, antigen retrieval, optimization with emphasis on incubation parameters and visualization methods. This review offers rationales to overcome the anticipated challenges in transition from immunohistochemistry to aptahistochemistry, which is deemed feasible for an average diagnostic pathology laboratory.

  13. Neurological soft signs discriminate schizophrenia from bipolar disorder.

    PubMed

    Rigucci, Silvia; Dimitri-Valente, Giorgia; Mandarelli, Gabriele; Manfredi, Giovanni; Comparelli, Anna; De Filippis, Sergio; Gherardelli, Simona; Bersani, Giuseppe; Girardi, Paolo; Ferracuti, Stefano

    2014-03-01

    Although neurological soft signs have been consistently described in patients with schizophrenia, their diagnostic specificity is not well clarified. To test the hypothesis that neurological soft signs are specifically related to schizophrenia, we examined 305 subjects (patients with schizophrenia-spectrum disorder, n=167; patients with bipolar I disorder, n=88; controls, n=50). Neurological soft signs were assessed using the Neurological Evaluation Scale (NES). Multiple logistic regression analysis was used to compute the diagnostic predictive power of neurological soft signs. Patients in the schizophrenia-spectrum disorder group were found to have significantly greater neurological impairment (NES total score=23.9, standard deviation [SD] 11.2) than those in the bipolar disorder group (NES total score=18.2, SD 7.6; p<0.001). Neurological functioning was closely associated with psychopathology (all p<0.001). The NES total score reliably distinguished patients with schizophrenia spectrum disorders from those with bipolar disorder in 68.7% of the cases (p<0.001). Moreover, a particular set of neurological soft signs showed specificity for the schizophrenia-spectrum disorder diagnostic group. Our findings suggest that schizophrenia and bipolar disorder can be distinguished in terms of neurological impairment. Furthermore, we recommend the utility of neurological soft signs as a useful, quantifiable, sensitive, and inexpensive tool for the diagnostic work-up of schizophrenia.

  14. Nested-PCR and a new ELISA-based NovaLisa test kit for malaria diagnosis in an endemic area of Thailand.

    PubMed

    Thongdee, Pimwan; Chaijaroenkul, Wanna; Kuesap, Jiraporn; Na-Bangchang, Kesara

    2014-08-01

    Microscopy is considered as the gold standard for malaria diagnosis although its wide application is limited by the requirement of highly experienced microscopists. PCR and serological tests provide efficient diagnostic performance and have been applied for malaria diagnosis and research. The aim of this study was to investigate the diagnostic performance of nested PCR and a recently developed an ELISA-based new rapid diagnosis test (RDT), NovaLisa test kit, for diagnosis of malaria infection, using microscopic method as the gold standard. The performance of nested-PCR as a malaria diagnostic tool is excellent with respect to its high accuracy, sensitivity, specificity, and ability to discriminate Plasmodium species. The sensitivity and specificity of nested-PCR compared with the microscopic method for detection of Plasmodium falciparum, Plasmodium vivax, and P. falciparum/P. vivax mixed infection were 71.4 vs 100%, 100 vs 98.7%, and 100 vs 95.0%, respectively. The sensitivity and specificity of the ELISA-based NovaLisa test kit compared with the microscopic method for detection of Plasmodium genus were 89.0 vs 91.6%, respectively. NovaLisa test kit provided comparable diagnostic performance. Its relatively low cost, simplicity, and rapidity enables large scale field application.

  15. Ana o 3-specific IgE is a good predictor for clinically relevant cashew allergy in children.

    PubMed

    Lange, L; Lasota, L; Finger, A; Vlajnic, D; Büsing, S; Meister, J; Broekaert, I; Pfannenstiel, C; Friedrichs, F; Price, M; Trendelenburg, V; Niggemann, B; Beyer, K

    2017-04-01

    Component-resolved diagnostics using specific IgE to 2 S albumins has shown to be a valuable new option in diagnostic procedure. Ana o 3 is a 2 S albumin from cashew. The aim of this study was to investigate the role of Ana o 3-specific serum IgE in the diagnosis of cashew allergy and to identify cut-off levels to replace oral food challenges. Moreover, the value of additional determination of total IgE has been investigated. In a multicentre study, we analysed specific IgE to cashew extract and Ana o 3 as well as total IgE in children with suspected cashew allergy using the ImmunoCAP-FEIA and a standardized diagnostic procedure including oral challenges where indicated. A total of 61 patients were included in the study. Forty-two were allergic to cashew, and 19 were tolerant. In receiver operating curves, Ana o 3 discriminates between allergic and tolerant children better than cashew-specific IgE with an area under the curve of 0.94 vs 0.78. The ratio of Ana o 3-specific IgE to total IgE did not further improve the diagnostic procedure. Probability curves for Ana o 3-specific IgE have been calculated, and a 95% probability could be estimated at 2.0 kU/l. Specific IgE to Ana o 3 is a valuable tool for the diagnosis of cashew allergy. Considering its positive predictive value, it might allow to make a considerable number of oral challenges superfluous. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Comparison of loop-mediated isothermal amplification assay and smear microscopy with culture for the diagnostic accuracy of tuberculosis.

    PubMed

    Gelaw, Baye; Shiferaw, Yitayal; Alemayehu, Marta; Bashaw, Abate Assefa

    2017-01-17

    Tuberculosis (TB) caused by Mycobacterium tuberculosis is one of the leading causes of death from infectious diseases worldwide. Sputum smear microscopy remains the most widely available pulmonary TB diagnostic tool particularly in resource limited settings. A highly sensitive diagnostic with minimal infrastructure, cost and training is required. Hence, we assessed the diagnostic performance of Loop-mediated isothermal amplification (LAMP) assay in detecting M.tuberculosis infection in sputum sample compared to LED fluorescent smear microscopy and culture. A cross-sectional study was conducted at the University of Gondar Hospital from June 01, 2015 to August 30, 2015. Pulmonary TB diagnosis using sputum LED fluorescence smear microscopy, TB-LAMP assay and culture were done. A descriptive analysis was used to determine demographic characteristics of the study participants. Analysis of sensitivity and specificity for smear microscopy and TB-LAMP compared with culture as a reference test was performed. Cohen's kappa was calculated as a measure of agreement between the tests. A total of 78 pulmonary presumptive TB patients sputum sample were analyzed. The overall sensitivity and specificity of LAMP were 75 and 98%, respectively. Among smear negative sputum samples, 33.3% sensitivity and 100% specificity of LAMP were observed. Smear microscopy showed 78.6% sensitivity and 98% specificity. LAMP and smear in series had sensitivity of 67.8% and specificity of 100%. LAMP and smear in parallel had sensitivity of 85.7% and specificity of 96%. The agreement between LAMP and fluorescent smear microscopy tests was very good (κ = 0.83, P-value ≤0.0001). TB-LAMP showed similar specificity but a slightly lower sensitivity with LED fluorescence microscopy. The specificity of LAMP and smear microscopy in series was high. The sensitivity of LAMP was insufficient for smear negative sputum samples.

  17. SNP-associations and phenotype predictions from hundreds of microbial genomes without genome alignments.

    PubMed

    Hall, Barry G

    2014-01-01

    SNP-association studies are a starting point for identifying genes that may be responsible for specific phenotypes, such as disease traits. The vast bulk of tools for SNP-association studies are directed toward SNPs in the human genome, and I am unaware of any tools designed specifically for such studies in bacterial or viral genomes. The PPFS (Predict Phenotypes From SNPs) package described here is an add-on to kSNP , a program that can identify SNPs in a data set of hundreds of microbial genomes. PPFS identifies those SNPs that are non-randomly associated with a phenotype based on the χ² probability, then uses those diagnostic SNPs for two distinct, but related, purposes: (1) to predict the phenotypes of strains whose phenotypes are unknown, and (2) to identify those diagnostic SNPs that are most likely to be causally related to the phenotype. In the example illustrated here, from a set of 68 E. coli genomes, for 67 of which the pathogenicity phenotype was known, there were 418,500 SNPs. Using the phenotypes of 36 of those strains, PPFS identified 207 diagnostic SNPs. The diagnostic SNPs predicted the phenotypes of all of the genomes with 97% accuracy. It then identified 97 SNPs whose probability of being causally related to the pathogenic phenotype was >0.999. In a second example, from a set of 116 E. coli genome sequences, using the phenotypes of 65 strains PPFS identified 101 SNPs that predicted the source host (human or non-human) with 90% accuracy.

  18. Walking on thin ice! Identifying methamphetamine "drug mules" on digital plain radiography.

    PubMed

    Abdul Rashid, S N; Mohamad Saini, S B; Abdul Hamid, S; Muhammad, S J; Mahmud, R; Thali, M J; Flach, P M

    2014-04-01

    The purpose of this study was to retrospectively evaluate the sensitivity, specificity and accuracy of identifying methamphetamine (MA) internal payloads in "drug mules" by plain abdominal digital radiography (DR). The study consisted of 35 individuals suspected of internal MA drug containers. A total of 59 supine digital radiographs were collected. An overall calculation regarding the diagnostic accuracy for all "drug mules" and a specific evaluation concerning the radiological appearance of drug packs as well as the rate of clearance and complications in correlation with the reader's experience were performed. The gold standard was the presence of secured drug packs in the faeces. There were 16 true-positive "drug mules" identified. DR of all drug carriers for Group 1 (forensic imaging experienced readers, n = 2) exhibited a sensitivity of 100%, a mean specificity of 76.3%, positive predictive value (PPV) of 78.5%, negative predictive value (NPV) of 100% and a mean accuracy 87.2%. Group 2 (inexperienced readers, n = 3) showed a lower sensitivity (93.7%), a mean specificity of 86%, a PPV of 86.5%, an NPV of 94.1% and a mean accuracy of 89.5%. The interrater agreement within Group 1 was 0.72 and within Group 2 averaged to 0.79, indicating a fair to very good agreement. DR is a valuable screening tool in cases of MA body packers with huge internal payloads being associated with a high diagnostic insecurity. Diagnostic insecurity on plain films may be overcome by low-dose CT as a cross-sectional imaging modality and addressed by improved radiological education in reporting drug carriers on imaging. Diagnostic signs (double-condom and halo signs) on digital plain radiography are specific in MA "drug mules", although DR is associated with high diagnostic insecurity and underreports the total internal payload.

  19. A systematic review of diagnostic criteria for psoriasis in adults and children: evidence from studies with a primary aim to develop or validate diagnostic criteria.

    PubMed

    Burden-Teh, E; Phillips, R C; Thomas, K S; Ratib, S; Grindlay, D; Murphy, R

    2017-11-06

    The diagnosis of psoriasis in adults and children is made clinically, for both patient management and the selection of participants in research. Diagnostic criteria provide a structure for clinical assessment, which in turn helps standardize patient recruitment into clinical trials and case definitions in observational studies. The aim of this systematic review was to identify and critically appraise the published studies to date that had a primary research aim to develop or validate diagnostic criteria for psoriasis. A search of Ovid MEDLINE and Ovid Embase was conducted in October 2016. The primary objective was to record the sensitivity and specificity of diagnostic criteria for psoriasis. Secondary objectives included diagnostic recommendations, applicability to children and study characteristics. Diagnostic accuracy studies were critically appraised for risk of bias using the QUADAS-2 tool. Twenty-three studies met the inclusion criteria. None detailed clinical examination-based diagnostic criteria. The included criteria varied from genetic and molecular diagnostic models to skin imaging, histopathology, and questionnaire-based, computer-aided and traditional Chinese medicine criteria. High sensitivity and specificity (> 90%) were reported in many studies. However, the study authors often did not specify how the criteria would be used clinically or in research. This review identified studies with varying risk of bias, and due to each study developing separate criteria meta-analysis was not possible. Clinical examination-based diagnostic criteria are currently lacking for psoriasis. Future research could follow an international collaborative approach and employ study designs allowing high-quality diagnostic accuracy testing. Existing and newly developed criteria require validation. © 2017 British Association of Dermatologists.

  20. INCLEN Diagnostic Tool for Autism Spectrum Disorder (INDT-ASD): development and validation.

    PubMed

    Juneja, Monica; Mishra, Devendra; Russell, Paul S S; Gulati, Sheffali; Deshmukh, Vaishali; Tudu, Poma; Sagar, Rajesh; Silberberg, Donald; Bhutani, Vinod K; Pinto, Jennifer M; Durkin, Maureen; Pandey, Ravindra M; Nair, M K C; Arora, Narendra K

    2014-05-01

    To develop and validate INCLEN Diagnostic Tool for Autism Spectrum Disorder (INDT-ASD). Diagnostic test evaluation by cross sectional design. Four tertiary pediatric neurology centers in Delhi and Thiruvanthapuram, India. Children aged 2-9 years were enrolled in the study. INDT-ASD and Childhood Autism Rating Scale (CARS) were administered in a randomly decided sequence by trained psychologist, followed by an expert evaluation by DSM-IV TR diagnostic criteria (gold standard). Psychometric parameters of diagnostic accuracy, validity (construct, criterion and convergent) and internal consistency. 154 children (110 boys, mean age 64.2 mo) were enrolled. The overall diagnostic accuracy (AUC=0.97, 95% CI 0.93, 0.99; P<0.001) and validity (sensitivity 98%, specificity 95%, positive predictive value 91%, negative predictive value 99%) of INDT-ASD for Autism spectrum disorder were high, taking expert diagnosis using DSM-IV-TR as gold standard. The concordance rate between the INDT-ASD and expert diagnosis for 'ASD group' was 82.52% [Cohen's k=0.89; 95% CI (0.82, 0.97); P=0.001]. The internal consistency of INDT-ASD was 0.96. The convergent validity with CARS (r = 0.73, P= 0.001) and divergent validity with Binet-Kamat Test of intelligence (r = -0.37; P=0.004) were significantly high. INDT-ASD has a 4-factor structure explaining 85.3% of the variance. INDT-ASD has high diagnostic accuracy, adequate content validity, good internal consistency high criterion validity and high to moderate convergent validity and 4-factor construct validity for diagnosis of Autistm spectrum disorder.

  1. Impacts of Lateral Boundary Conditions on US Ozone ...

    EPA Pesticide Factsheets

    Chemical boundary conditions are a key input to regional-scale photochemical models. In this study, we perform annual simulations over North America with chemical boundary conditions prepared from two global models (GEOS-CHEM and Hemispheric CMAQ). Results indicate that the impacts of different boundary conditions on ozone can be significant throughout the year. The National Exposure Research Laboratory (NERL) Computational Exposure Division (CED) develops and evaluates data, decision-support tools, and models to be applied to media-specific or receptor-specific problem areas. CED uses modeling-based approaches to characterize exposures, evaluate fate and transport, and support environmental diagnostics/forensics with input from multiple data sources. It also develops media- and receptor-specific models, process models, and decision support tools for use both within and outside of EPA.

  2. Real-time fluorescence loop mediated isothermal amplification for the diagnosis of malaria.

    PubMed

    Lucchi, Naomi W; Demas, Allison; Narayanan, Jothikumar; Sumari, Deborah; Kabanywanyi, Abdunoor; Kachur, S Patrick; Barnwell, John W; Udhayakumar, Venkatachalam

    2010-10-29

    Molecular diagnostic methods can complement existing tools to improve the diagnosis of malaria. However, they require good laboratory infrastructure thereby restricting their use to reference laboratories and research studies. Therefore, adopting molecular tools for routine use in malaria endemic countries will require simpler molecular platforms. The recently developed loop-mediated isothermal amplification (LAMP) method is relatively simple and can be improved for better use in endemic countries. In this study, we attempted to improve this method for malaria diagnosis by using a simple and portable device capable of performing both the amplification and detection (by fluorescence) of LAMP in one platform. We refer to this as the RealAmp method. Published genus-specific primers were used to test the utility of this method. DNA derived from different species of malaria parasites was used for the initial characterization. Clinical samples of P. falciparum were used to determine the sensitivity and specificity of this system compared to microscopy and a nested PCR method. Additionally, directly boiled parasite preparations were compared with a conventional DNA isolation method. The RealAmp method was found to be simple and allowed real-time detection of DNA amplification. The time to amplification varied but was generally less than 60 minutes. All human-infecting Plasmodium species were detected. The sensitivity and specificity of RealAmp in detecting P. falciparum was 96.7% and 91.7% respectively, compared to microscopy and 98.9% and 100% respectively, compared to a standard nested PCR method. In addition, this method consistently detected P. falciparum from directly boiled blood samples. This RealAmp method has great potential as a field usable molecular tool for diagnosis of malaria. This tool can provide an alternative to conventional PCR based diagnostic methods for field use in clinical and operational programs.

  3. Improved reliability of serological tools for the diagnosis of West Nile fever in horses within Europe

    PubMed Central

    Lowenski, Steeve; Durand, Benoit; Bahuon, Céline; Zientara, Stéphan; Lecollinet, Sylvie

    2017-01-01

    West Nile Fever is a zoonotic disease caused by a mosquito-borne flavivirus, WNV. By its clinical sensitivity to the disease, the horse is a useful sentinel of infection. Because of the virus’ low-level, short-term viraemia in horses, the primary tools used to diagnose WNV are serological tests. Inter-laboratory proficiency tests (ILPTs) were held in 2010 and 2013 to evaluate WNV serological diagnostic tools suited for the European network of National Reference Laboratories (NRLs) for equine diseases. These ILPTs were designed to evaluate the laboratories’ and methods’ performances in detecting WNV infection in horses through serology. The detection of WNV immunoglobulin G (IgG) antibodies by ELISA is widely used in Europe, with 17 NRLs in 2010 and 20 NRLs in 2013 using IgG WNV assays. Thanks to the development of new commercial IgM capture kits, WNV IgM capture ELISAs were rapidly implemented in NRLs between 2010 (4 NRLs) and 2013 (13 NRLs). The use of kits allowed the quick standardisation of WNV IgG and IgM detection assays in NRLs with more than 95% (20/21) and 100% (13/13) of satisfactory results respectively in 2013. Conversely, virus neutralisation tests (VNTs) were implemented in 33% (7/21) of NRLs in 2013 and their low sensitivity was evidenced in 29% (2/7) of NRLs during this ILPT. A comparison of serological diagnostic methods highlighted the higher sensitivity of IgG ELISAs compared to WNV VNTs. They also revealed that the low specificity of IgG ELISA kits meant that it could detect animals infected with other flaviviruses. In contrast VNT and IgM ELISA assays were highly specific and did not detect antibodies against related flaviviruses. These results argue in favour of the need for and development of new, specific serological diagnostic assays that could be easily transferred to partner laboratories. PMID:28915240

  4. Echocardiography in the intensive care unit: from evolution to revolution?

    PubMed

    Vieillard-Baron, Antoine; Slama, Michel; Cholley, Bernard; Janvier, Gérard; Vignon, Philippe

    2008-02-01

    Over recent decades, echocardiography has become a pivotal diagnostic tool for the assessment of patients with hemodynamic compromise in general intensive care units (ICUs). In addition to its imaging capability, echocardiography provides a detailed cardiovascular assessment, based on the combination of real-time two-dimensional evaluation of cardiac structure and function and hemodynamic information provided by Doppler measurement of blood flow velocity. However, despite its ease of use, portability and accuracy, the diffusion of echocardiography among ICUs has been limited by various factors. We discuss here the main reasons for the slow acceptance by the critical care community of echocardiography as a first-line diagnostic tool for the evaluation of hemodynamically unstable patients. One of these reasons is probably the absence, in most countries, of a training program in echocardiography specifically dedicated to intensivists. We report recent French experience in the organization of specific echocardiographic certification aimed at intensivists and anesthesiologists. We strongly believe that a broader use of echocardiography would be beneficial in terms of diagnostic capability and patient management. Therefore, we would like to involve colleagues from other countries and the European Society of Intensive Care Medicine in defining the objectives of echocardiography training for intensivists and in organizing postgraduate courses and training programs aimed at developing the use of echocardiography in ICUs. This would allow the current "evolution" in mentalities to become a true "revolution" in our daily practice.

  5. A meta-analysis of use of Prostate Imaging Reporting and Data System Version 2 (PI-RADS V2) with multiparametric MR imaging for the detection of prostate cancer.

    PubMed

    Zhang, Li; Tang, Min; Chen, Sipan; Lei, Xiaoyan; Zhang, Xiaoling; Huan, Yi

    2017-12-01

    This meta-analysis was undertaken to review the diagnostic accuracy of PI-RADS V2 for prostate cancer (PCa) detection with multiparametric MR (mp-MR). A comprehensive literature search of electronic databases was performed by two observers independently. Inclusion criteria were original research using the PI-RADS V2 system in reporting prostate MRI. The methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Data necessary to complete 2 × 2 contingency tables were obtained from the included studies. Thirteen studies (2,049 patients) were analysed. This is an initial meta-analysis of PI-RADs V2 and the overall diagnostic accuracy in diagnosing PCa was as follows: pooled sensitivity, 0.85 (0.78-0.91); pooled specificity, 0.71 (0.60-0.80); pooled positive likelihood ratio (LR+), 2.92 (2.09-4.09); pooled negative likelihood ratio (LR-), 0.21 (0.14-0.31); pooled diagnostic odds ratio (DOR), 14.08 (7.93-25.01), respectively. Positive predictive values ranged from 0.54 to 0.97 and negative predictive values ranged from 0.26 to 0.92. Currently available evidence indicates that PI-RADS V2 appears to have good diagnostic accuracy in patients with PCa lesions with high sensitivity and moderate specificity. However, no recommendation regarding the best threshold can be provided because of heterogeneity. • PI-RADS V2 shows good diagnostic accuracy for PCa detection. • Initially pooled specificity of PI-RADS v2 remains moderate. • PCa detection is increased by experienced radiologists. • There is currently a high heterogeneity in prostate diagnostics with MRI.

  6. Predicting risk and outcomes for frail older adults: an umbrella review of frailty screening tools

    PubMed Central

    Apóstolo, João; Cooke, Richard; Bobrowicz-Campos, Elzbieta; Santana, Silvina; Marcucci, Maura; Cano, Antonio; Vollenbroek-Hutten, Miriam; Germini, Federico; Holland, Carol

    2017-01-01

    EXECUTIVE SUMMARY Background A scoping search identified systematic reviews on diagnostic accuracy and predictive ability of frailty measures in older adults. In most cases, research was confined to specific assessment measures related to a specific clinical model. Objectives To summarize the best available evidence from systematic reviews in relation to reliability, validity, diagnostic accuracy and predictive ability of frailty measures in older adults. Inclusion criteria Population Older adults aged 60 years or older recruited from community, primary care, long-term residential care and hospitals. Index test Available frailty measures in older adults. Reference test Cardiovascular Health Study phenotype model, the Canadian Study of Health and Aging cumulative deficit model, Comprehensive Geriatric Assessment or other reference tests. Diagnosis of interest Frailty defined as an age-related state of decreased physiological reserves characterized by an increased risk of poor clinical outcomes. Types of studies Quantitative systematic reviews. Search strategy A three-step search strategy was utilized to find systematic reviews, available in English, published between January 2001 and October 2015. Methodological quality Assessed by two independent reviewers using the Joanna Briggs Institute critical appraisal checklist for systematic reviews and research synthesis. Data extraction Two independent reviewers extracted data using the standardized data extraction tool designed for umbrella reviews. Data synthesis Data were only presented in a narrative form due to the heterogeneity of included reviews. Results Five reviews with a total of 227,381 participants were included in this umbrella review. Two reviews focused on reliability, validity and diagnostic accuracy; two examined predictive ability for adverse health outcomes; and one investigated validity, diagnostic accuracy and predictive ability. In total, 26 questionnaires and brief assessments and eight frailty indicators were analyzed, most of which were applied to community-dwelling older people. The Frailty Index was examined in almost all these dimensions, with the exception of reliability, and its diagnostic and predictive characteristics were shown to be satisfactory. Gait speed showed high sensitivity, but only moderate specificity, and excellent predictive ability for future disability in activities of daily living. The Tilburg Frailty Indicator was shown to be a reliable and valid measure for frailty screening, but its diagnostic accuracy was not evaluated. Screening Letter, Timed-up-and-go test and PRISMA 7 (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) demonstrated high sensitivity and moderate specificity for identifying frailty. In general, low physical activity, variously measured, was one of the most powerful predictors of future decline in activities of daily living. Conclusion Only a few frailty measures seem to be demonstrably valid, reliable and diagnostically accurate, and have good predictive ability. Among them, the Frailty Index and gait speed emerged as the most useful in routine care and community settings. However, none of the included systematic reviews provided responses that met all of our research questions on their own and there is a need for studies that could fill this gap, covering all these issues within the same study. Nevertheless, it was clear that no suitable tool for assessing frailty appropriately in emergency departments was identified. PMID:28398987

  7. A PCR-based tool for the cultivation-independent monitoring of Pandora neoaphidis.

    PubMed

    Fournier, A; Enkerli, J; Keller, S; Widmer, F

    2008-09-01

    Pandora neoaphidis is one of the most important fungal pathogens of aphids and has a great potential for use in biocontrol. Little is known on how this fungus persists in an area and in particular on its overwintering strategies. It is hypothesized that natural areas play an important role for survival and that soil may serve as a source of inoculum for new aphid populations in spring. To test these hypotheses, a cultivation-independent PCR-based diagnostic tool was developed, that allows the detection of P. neoaphidis in the environment. Two P. neoaphidis specific PCR primer pairs were designed, targeting sequences in the ribosomal RNA gene cluster. Specificity of both primer pairs was demonstrated with P. neoaphidis and non-target close entomophthoralean relatives. Moreover, single amplicons of expected sizes were obtained with both primer pairs from various environmental sample types, including aphid cadavers, plant material, and soil. The PCR-based diagnostic tool was applied to investigate the persistence of P. neoaphidis in soil samples obtained in 2004/2005 from a nettle field harboring infected aphids in fall 2004. P. neoaphidis was detected in every sample collected in November 2004 and March 2005, suggesting an overwintering stage of P. neoaphidis in top soil layers. The developed cultivation-independent PCR-based tool will be valuable for further investigation of the ecology of P. neoaphidis and for the development and future implementation of management strategies against aphids involving conservation biocontrol.

  8. Using component technologies for web based wavelet enhanced mammographic image visualization.

    PubMed

    Sakellaropoulos, P; Costaridou, L; Panayiotakis, G

    2000-01-01

    The poor contrast detectability of mammography can be dealt with by domain specific software visualization tools. Remote desktop client access and time performance limitations of a previously reported visualization tool are addressed, aiming at more efficient visualization of mammographic image resources existing in web or PACS image servers. This effort is also motivated by the fact that at present, web browsers do not support domain-specific medical image visualization. To deal with desktop client access the tool was redesigned by exploring component technologies, enabling the integration of stand alone domain specific mammographic image functionality in a web browsing environment (web adaptation). The integration method is based on ActiveX Document Server technology. ActiveX Document is a part of Object Linking and Embedding (OLE) extensible systems object technology, offering new services in existing applications. The standard DICOM 3.0 part 10 compatible image-format specification Papyrus 3.0 is supported, in addition to standard digitization formats such as TIFF. The visualization functionality of the tool has been enhanced by including a fast wavelet transform implementation, which allows for real time wavelet based contrast enhancement and denoising operations. Initial use of the tool with mammograms of various breast structures demonstrated its potential in improving visualization of diagnostic mammographic features. Web adaptation and real time wavelet processing enhance the potential of the previously reported tool in remote diagnosis and education in mammography.

  9. The Shoulder Objective Practical Assessment Tool: Evaluation of a New Tool Assessing Residents Learning in Diagnostic Shoulder Arthroscopy.

    PubMed

    Talbot, Christopher L; Holt, Edward M; Gooding, Benjamin W T; Tennent, Thomas D; Foden, Philip

    2015-08-01

    To design and validate an objective practical assessment tool for diagnostic shoulder arthroscopy that would provide residents with a method to evaluate their progression in this field of surgery and to identify specific learning needs. We designed and evaluated the shoulder Objective Practical Assessment Tool (OPAT). The shoulder OPAT was designed by us, and scoring domains were created using a Delphi process. The shoulder OPAT was trialed by members of the British Elbow & Shoulder Society Education Committee for internal consistency and ease of use before being offered to other trainers and residents. Inter-rater reliability and intrarater reliability were calculated. One hundred forty orthopaedic residents, of varying seniority, within 5 training regions in the United Kingdom, were questioned regarding the tool. A pilot study of 6 residents was undertaken. Internal consistency was 0.77 (standardized Cronbach α). Inter-rater reliability was 0.60, and intrarater reliability was 0.82. The Spearman correlation coefficient (r) between the global summary score for the shoulder OPAT and the current assessment tool used in postgraduate training for orthopaedic residents undertaking diagnostic shoulder arthroscopy equaled 0.74. Of the residents, 82% agreed or strongly agreed when asked if the shoulder OPAT would be a useful tool in monitoring progression and 72% agreed or strongly agreed with the introduction of the shoulder OPAT within the orthopaedic domain. This study shows that the shoulder OPAT fulfills several aspects of reliability and validity when tested. Despite the inter-rater reliability being 0.60, we believe that the shoulder OPAT has the potential to play a role alongside the current assessment tool in the training of orthopaedic residents. The shoulder OPAT can be used to assess residents during shoulder arthroscopy and has the potential for use in medical education, as well as arthroscopic skills training in the operating theater. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  10. Novel Fitc-Labeled Igy Antibody: Fluorescence Imaging Toxoplasma Gondii In Vitro.

    PubMed

    Sert, Mehtap; Cakir Koc, Rabia; Budama Kilinc, Yasemin

    2017-04-12

    Toxoplasmosis is caused by T. gondii and can create serious health problems in humans and also worldwide economic harm. Because of the clinical and veterinary importance of toxoplasmosis, its timely and accurate diagnosis has a major impact on disease-fighting strategies. T. gondii surface antigen 1 (SAG1), an immunodominant-specific antigen, is often used as a diagnostic tool. Therefore, the aim of this study was the optimization of novel fluorescein isothiocyanate (FITC) labeling of the SAG1-specific IgY antibody to show the potential for immunofluorescence imaging of T. gondii in vitro. The specificity of IgY antibodies was controlled by an enzyme-linked immunosorbent assay (ELISA), and the concentration of the IgY antibody was detected using a spectrophotometer. The optimum incubation time and FITC concentration were determined with a fluorescence spectrometer. The obtained FITC-labeled IgY was used for marking T. gondii tachyzoites, which were cultured in vitro and viewed using light microscopy. The interaction of the fluorescence-labeled antibody and the T. gondii tachyzoites was examined with a fluorescence microscope. In this study, for the first time, a FITC-labeled anti-SAG1 IgY antibody was developed according to ELISA, fluorescence spectrometer, and fluorescence imaging of cell culture. In the future, the obtained FITC-labeled T. gondii tachyzoites' specific IgY antibodies may be used as diagnostic tools for the detection of T. gondii infections in different samples.

  11. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool.

    PubMed

    Mesquita, Flávio da Silva; Oliveira, Danielle Bruna Leal de; Crema, Daniela; Pinez, Célia Miranda Nunes; Colmanetti, Thaís Cristina; Thomazelli, Luciano Matsumia; Gilio, Alfredo Elias; Vieira, Sandra Elisabeth; Martinez, Marina Baquerizo; Botosso, Viviane Fongaro; Durigon, Edison Luiz

    The aim of this study was to evaluate the QuickVue ® RSV Test Kit (QUIDEL Corp, CA, USA) as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue ® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. From 313 positive samples by immunofluorescence assays, 282 (90%) were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue ® RSV Test and viral load or specific strain. The QuickVue ® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. This study demonstrated that the QuickVue ® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  12. Rapid and sensitive detection of Yersinia pestis using amplification of plague diagnostic bacteriophages monitored by real-time PCR.

    PubMed

    Sergueev, Kirill V; He, Yunxiu; Borschel, Richard H; Nikolich, Mikeljon P; Filippov, Andrey A

    2010-06-28

    Yersinia pestis, the agent of plague, has caused many millions of human deaths and still poses a serious threat to global public health. Timely and reliable detection of such a dangerous pathogen is of critical importance. Lysis by specific bacteriophages remains an essential method of Y. pestis detection and plague diagnostics. The objective of this work was to develop an alternative to conventional phage lysis tests--a rapid and highly sensitive method of indirect detection of live Y. pestis cells based on quantitative real-time PCR (qPCR) monitoring of amplification of reporter Y. pestis-specific bacteriophages. Plague diagnostic phages phiA1122 and L-413C were shown to be highly effective diagnostic tools for the detection and identification of Y. pestis by using qPCR with primers specific for phage DNA. The template DNA extraction step that usually precedes qPCR was omitted. phiA1122-specific qPCR enabled the detection of an initial bacterial concentration of 10(3) CFU/ml (equivalent to as few as one Y. pestis cell per 1-microl sample) in four hours. L-413C-mediated detection of Y. pestis was less sensitive (up to 100 bacteria per sample) but more specific, and thus we propose parallel qPCR for the two phages as a rapid and reliable method of Y. pestis identification. Importantly, phiA1122 propagated in simulated clinical blood specimens containing EDTA and its titer rise was detected by both a standard plating test and qPCR. Thus, we developed a novel assay for detection and identification of Y. pestis using amplification of specific phages monitored by qPCR. The method is simple, rapid, highly sensitive, and specific and allows the detection of only live bacteria.

  13. Ga-68-DOTA-TATE PET/CT for discrimination of tumors of the optic pathway.

    PubMed

    Klingenstein, Annemarie; Haug, Alexander R; Miller, Christina; Hintschich, Christoph

    2015-02-01

    Symptomatic tumors of the optic nerve pathway may endanger vision. They are difficult to classify by imaging alone and biopsy may damage visual function. Tumor pathology influences treatment decision and a diagnostic tool with a high sensitivity and specificity would therefore be invaluable. We hypothesized that Ga-68-DOTA-TATE PET/CT may help in discriminating optic nerve tumors as uptake of somatostatin is elevated in meningiomas. Ga-68-DOTA-TATE PET/CT was used to examine 13 patients with ambiguous, symptomatic lesions of the optic pathway for treatment planning. The presence or absence of meningioma was validated by histopathology or supplementary diagnostic work-up. Ga-68-DOTA-TATE PET/CT identified 10 meningiomas (en plaque = 1, optic nerve sheath = 4, sphenoidal = 5) correctly via increased SSTR (somatostatin receptor) expression (mean SUVmax (maximum standardized uptake value) = 14.3 ± 15.4). 3 tumors did not show elevated Ga-68-DOTA-TATE uptake (SUVmax = 2.1 ± 1.0). Subsumizing all clinical-radiological follow-up tools available, these lesions were classified as an intracerebral metastasis of an advanced gastric carcinoma, histologically proven inflammatory collagenous connective tissue and presumed leukemic infiltration of a newly diagnosed chronic lymphocytic leukemia. In this case series, Ga-68-DOTA-TATE PET/CT demonstrated both a sensitivity and specificity of 100%. Yet, the golden standard of histopathology was only available in a subset of patients included. Ga-68-DOTA-TATE PET/CT proved to be a valuable diagnostic tool for the correct classification of equivocal, symptomatic tumors of the anterior optic pathway requiring therapy. PET/CT results influenced therapy decision essentially in all cases.

  14. Plasma Diagnostics: Use and Justification in an Industrial Environment

    NASA Astrophysics Data System (ADS)

    Loewenhardt, Peter

    1998-10-01

    The usefulness and importance of plasma diagnostics have played a major role in the development of plasma processing tools in the semiconductor industry. As can be seen through marketing materials from semiconductor equipment manufacturers, results from plasma diagnostic equipment can be a powerful tool in selling the technological leadership of tool design. Some diagnostics have long been used for simple process control such as optical emission for endpoint determination, but in recent years more sophisticated and involved diagnostic tools have been utilized in chamber and plasma source development and optimization. It is now common to find an assortment of tools at semiconductor equipment companies such as Langmuir probes, mass spectrometers, spatial optical emission probes, impedance, ion energy and ion flux probes. An outline of how the importance of plasma diagnostics has grown at an equipment manufacturer over the last decade will be given, with examples of significant and useful results obtained. Examples will include the development and optimization of an inductive plasma source, trends and hardware effects on ion energy distributions, mass spectrometry influences on process development and investigations of plasma-wall interactions. Plasma diagnostic focus, in-house development and proliferation in an environment where financial justification requirements are both strong and necessary will be discussed.

  15. The diagnostic value and histologic correlate of distinct patterns of shiny white streaks for the diagnosis of melanoma: A retrospective, case-control study.

    PubMed

    Verzi, Anna Eliza; Quan, Victor L; Walton, Kara E; Martini, Mary C; Marghoob, Ashfaq A; Garfield, Erin M; Kong, Betty Y; Isales, Maria Cristina; VandenBoom, Timothy; Zhang, Bin; West, Dennis P; Gerami, Pedram

    2018-05-01

    Shiny white streaks (SWSs) are best visualized with polarized dermoscopy and correlate with dermal fibroplasia histopathologically. SWSs have been described at higher frequencies in melanomas than in benign nevi. We assessed the diagnostic value of different patterns of SWSs and their histologic correlate in melanocytic lesions. Polarized dermoscopic images of 1507 histopathologically diagnosed melanocytic neoplasms were analyzed for presence and pattern of SWSs. Histology was also reviewed for correlation. Among 1507 melanocytic neoplasms, SWSs were observed in 31 of 144 melanomas (22%) and 22 of 1363 benign neoplasms (1.6%) (P < .001). The sensitivity and specificity of SWSs for melanoma were 22% and 98%, respectively. Diffuse SWSs exhibited the greatest diagnostic value for melanoma, with sensitivity of 11.8% and specificity of 99.5%. Focal central and peripheral SWSs were comparable in diagnostic significance. The presence of SWSs was highly uncommon in dysplastic nevi, whereas in certain benign subgroups of nevi such as Spitz nevi and atypical genital special site nevi, SWSs were not uncommon. Diffuse SWSs correlated with greater breadth of deep fibroplasia than focal SWSs (P = .009), and SWSs correlated with greater Breslow depth among melanomas (P = .007). This study was retrospective. Polarized dermoscopy is a valuable diagnostic tool in the identification of SWSs, a feature that is highly specific for melanoma. Copyright © 2017 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  16. The future of targeted peptidomics.

    PubMed

    Findeisen, Peter

    2013-12-01

    Targeted MS is becoming increasingly important for sensitive and specific quantitative detection of proteins and respective PTMs. In this article, Ceglarek et al. [Proteomics Clin. Appl. 2013, 7, 794-801] present an LC-MS-based method for simultaneous quantitation of seven apolipoproteins in serum specimens. The assay fulfills many necessities of routine diagnostic applications, namely, low cost, high throughput, and good reproducibility. We anticipate that validation of new biomarkers will speed up with this technology and the palette of laboratory-based diagnostic tools will hopefully be augmented significantly in the near future. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. DSM-III as a research tool.

    PubMed

    Treece, C

    1982-05-01

    The author describes the use of the DSM-III's diagnostic criteria and classification system as a research instrument and discusses some of the advantages and drawbacks of DMS-III for a specific type of study. A rearrangement of the hierarchical order of the DSM-III diagnostic classes is suggested. This rearrangement provides for levels of certainty in analyzing interrater reliability and offers a simplified framework for summarizing group data. When this approach is combined with a structured interview and response format, it provides a flexible way of managing a large classification system for a smaller study without sacrificing standardization.

  18. Fusion genes in solid tumors: an emerging target for cancer diagnosis and treatment.

    PubMed

    Parker, Brittany C; Zhang, Wei

    2013-11-01

    Studies over the past decades have uncovered fusion genes, a class of oncogenes that provide immense diagnostic and therapeutic advantages because of their tumor-specific expression. Originally associated with hemotologic cancers, fusion genes have recently been discovered in a wide array of solid tumors, including sarcomas, carcinomas, and tumors of the central nervous system. Fusion genes are attractive as both therapeutic targets and diagnostic tools due to their inherent expression in tumor tissue alone. Therefore, the discovery and elucidation of fusion genes in various cancer types may provide more effective therapies in the future for cancer patients.

  19. Recent advances in the diagnosis and treatment of niemann-pick disease type C in children: a guide to early diagnosis for the general pediatrician.

    PubMed

    Alobaidy, Hanna

    2015-01-01

    Niemann-Pick disease (NP-C) is a lysosomal storage disease in which impaired intracellular lipid transport leads to accumulation of cholesterol and glycosphingolipids in various neurovisceral tissues. It is an autosomal recessive disorder, caused by mutations in the NPC1 or NPC2 genes. The clinical spectrum is grouped by the age of onset and onset of neurological manifestation: pre/perinatal; early infantile; late infantile; and juvenile periods. The NP-C Suspicion Index (SI) screening tool was developed to identify suspected patients with this disease. It is especially good at recognizing the disease in patients older than four years of age. Biochemical tests involving genetic markers and Filipin staining of skin fibroblast are being employed to assist diagnosis. Therapy is mostly supportive and since 2009, the first specific therapy approved for use was Miglustat (Zavesca) aimed at stabilizing the rate of progression of neurological manifestation. The prognosis correlates with age at onset of neurological signs; patients with early onset form progress faster. The NP-C disease has heterogeneous neurovisceral manifestations. A SI is a screening tool that helps in diagnostic process. Filipin staining test is a specific biomarker diagnostic test. Miglustat is the first disease-specific therapy.

  20. The role of spectrophotometry in the diagnosis of melanoma.

    PubMed

    Ascierto, Paolo A; Palla, Marco; Ayala, Fabrizio; De Michele, Ileana; Caracò, Corrado; Daponte, Antonio; Simeone, Ester; Mori, Stefano; Del Giudice, Maurizio; Satriano, Rocco A; Vozza, Antonio; Palmieri, Giuseppe; Mozzillo, Nicola

    2010-08-13

    Spectrophotometry (SPT) could represent a promising technique for the diagnosis of cutaneous melanoma (CM) at earlier stages of the disease. Starting from our experience, we further assessed the role of SPT in CM early detection. During a health campaign for malignant melanoma at National Cancer Institute of Naples, we identified a subset of 54 lesions to be addressed to surgical excision and histological examination. Before surgery, all patients were investigated by clinical and epiluminescence microscopy (ELM) screenings; selected lesions underwent spectrophotometer analysis. For SPT, we used a video spectrophotometer imaging system (Spectroshade MHT S.p.A., Verona, Italy). Among the 54 patients harbouring cutaneous pigmented lesions, we performed comparison between results from the SPT screening and the histological diagnoses as well as evaluation of both sensitivity and specificity in detecting CM using either SPT or conventional approaches. For all pigmented lesions, agreement between histology and SPT classification was 57.4%. The sensitivity and specificity of SPT in detecting melanoma were 66.6% and 76.2%, respectively. Although SPT is still considered as a valuable diagnostic tool for CM, its low accuracy, sensitivity, and specificity represent the main hamper for the introduction of such a methodology in clinical practice. Dermoscopy remains the best diagnostic tool for the preoperative diagnosis of pigmented skin lesions.

  1. The role of spectrophotometry in the diagnosis of melanoma

    PubMed Central

    2010-01-01

    Background Spectrophotometry (SPT) could represent a promising technique for the diagnosis of cutaneous melanoma (CM) at earlier stages of the disease. Starting from our experience, we further assessed the role of SPT in CM early detection. Methods During a health campaign for malignant melanoma at National Cancer Institute of Naples, we identified a subset of 54 lesions to be addressed to surgical excision and histological examination. Before surgery, all patients were investigated by clinical and epiluminescence microscopy (ELM) screenings; selected lesions underwent spectrophotometer analysis. For SPT, we used a video spectrophotometer imaging system (Spectroshade® MHT S.p.A., Verona, Italy). Results Among the 54 patients harbouring cutaneous pigmented lesions, we performed comparison between results from the SPT screening and the histological diagnoses as well as evaluation of both sensitivity and specificity in detecting CM using either SPT or conventional approaches. For all pigmented lesions, agreement between histology and SPT classification was 57.4%. The sensitivity and specificity of SPT in detecting melanoma were 66.6% and 76.2%, respectively. Conclusions Although SPT is still considered as a valuable diagnostic tool for CM, its low accuracy, sensitivity, and specificity represent the main hamper for the introduction of such a methodology in clinical practice. Dermoscopy remains the best diagnostic tool for the preoperative diagnosis of pigmented skin lesions. PMID:20707921

  2. Identification of facilitators and barriers to residents' use of a clinical reasoning tool.

    PubMed

    DiNardo, Deborah; Tilstra, Sarah; McNeil, Melissa; Follansbee, William; Zimmer, Shanta; Farris, Coreen; Barnato, Amber E

    2018-03-28

    While there is some experimental evidence to support the use of cognitive forcing strategies to reduce diagnostic error in residents, the potential usability of such strategies in the clinical setting has not been explored. We sought to test the effect of a clinical reasoning tool on diagnostic accuracy and to obtain feedback on its usability and acceptability. We conducted a randomized behavioral experiment testing the effect of this tool on diagnostic accuracy on written cases among post-graduate 3 (PGY-3) residents at a single internal medical residency program in 2014. Residents completed written clinical cases in a proctored setting with and without prompts to use the tool. The tool encouraged reflection on concordant and discordant aspects of each case. We used random effects regression to assess the effect of the tool on diagnostic accuracy of the independent case sets, controlling for case complexity. We then conducted audiotaped structured focus group debriefing sessions and reviewed the tapes for facilitators and barriers to use of the tool. Of 51 eligible PGY-3 residents, 34 (67%) participated in the study. The average diagnostic accuracy increased from 52% to 60% with the tool, a difference that just met the test for statistical significance in adjusted analyses (p=0.05). Residents reported that the tool was generally acceptable and understandable but did not recognize its utility for use with simple cases, suggesting the presence of overconfidence bias. A clinical reasoning tool improved residents' diagnostic accuracy on written cases. Overconfidence bias is a potential barrier to its use in the clinical setting.

  3. An ontology-driven, diagnostic modeling system.

    PubMed

    Haug, Peter J; Ferraro, Jeffrey P; Holmen, John; Wu, Xinzi; Mynam, Kumar; Ebert, Matthew; Dean, Nathan; Jones, Jason

    2013-06-01

    To present a system that uses knowledge stored in a medical ontology to automate the development of diagnostic decision support systems. To illustrate its function through an example focused on the development of a tool for diagnosing pneumonia. We developed a system that automates the creation of diagnostic decision-support applications. It relies on a medical ontology to direct the acquisition of clinic data from a clinical data warehouse and uses an automated analytic system to apply a sequence of machine learning algorithms that create applications for diagnostic screening. We refer to this system as the ontology-driven diagnostic modeling system (ODMS). We tested this system using samples of patient data collected in Salt Lake City emergency rooms and stored in Intermountain Healthcare's enterprise data warehouse. The system was used in the preliminary development steps of a tool to identify patients with pneumonia in the emergency department. This tool was compared with a manually created diagnostic tool derived from a curated dataset. The manually created tool is currently in clinical use. The automatically created tool had an area under the receiver operating characteristic curve of 0.920 (95% CI 0.916 to 0.924), compared with 0.944 (95% CI 0.942 to 0.947) for the manually created tool. Initial testing of the ODMS demonstrates promising accuracy for the highly automated results and illustrates the route to model improvement. The use of medical knowledge, embedded in ontologies, to direct the initial development of diagnostic computing systems appears feasible.

  4. Analysis of MAST-CLA Results as a Diagnostic Tool in Allergic Skin Diseases

    PubMed Central

    Shin, Jung Won; Jin, Seon-pil; Lee, Jong Hee

    2010-01-01

    Background Urticaria and atopic dermatitis are representative allergic skin diseases that can be mediated by IgE. Measuring levels of specific IgE can be used to confirm causative agents of these skin diseases. Objective To analyze results from the multiple allergosorbent test chemiluminescent assay (MAST-CLA), which measures specific IgE in the presence of a causative agent/allergen, in IgE-mediated skin diseases. Methods A total of 404 patients with urticaria, atopic dermatitis or pruritus were enrolled in the present study. Positive rates of specific IgE as well as total serum IgE from the MAST-CLA were compared. Results Positive rates of specific IgE were highest in atopic dermatitis patients, followed by urticaria, and then pruritus, with 57.0%, 37.1%, and 20.8%, respectively (p<0.05). House dust mite species were the most common allergens in both atopic dermatitis and urticaria skin diseases. There were no differences in the overall MAST-CLA results between acute and chronic urticaria. The relative positive rate of inhalant allergen was significantly higher in adult than in child atopic dermatitis patients. Conclusion Results from the MAST-CLA showed diversity among the three disease groups, and within each disease group, with different positive rates of specific IgE, a different mean allergen number per patient, and so on. Therefore, we concluded that MAST-CLA could be a useful diagnostic tool for various allergic skin diseases. PMID:20548878

  5. Loop-mediated isothermal amplification (LAMP) assays for the species-specific detection of Eimeria that infect chickens

    PubMed Central

    2011-01-01

    Background Eimeria parasites can cause the disease coccidiosis in poultry and even subclinical infection can incur economic loss. Diagnosis of infection predominantly relies on traditional techniques including lesion scoring and faecal microscopy despite the availability of sensitive molecular assays, largely due to cost and the requirement for specialist equipment. Despite longstanding proven efficacy these traditional techniques demand time and expertise, can be highly subjective and may under-diagnose subclinical disease. Recognition of the tight economic margins prevailing in modern poultry production and the impact of avian coccidiosis on poverty in many parts of the world has highlighted a requirement for a panel of straightforward and sensitive, but cost-effective, Eimeria species-specific diagnostic assays. Results Loop-mediated isothermal amplification (LAMP) is an uncomplicated, quick and relatively inexpensive diagnostic tool. In this study we have developed a panel of species-specific LAMP assays targeting the seven Eimeria species that infect the chicken. Each assay has been shown to be genuinely species-specific with the capacity to detect between one and ten eimerian genomes, equivalent to less than a single mature schizont. Development of a simple protocol for template DNA preparation from tissue collected post mortem with no requirement for specialist laboratory equipment supports the use of these assays in routine diagnosis of eimerian infection. Preliminary field testing supports this hypothesis. Conclusions Development of a panel of sensitive species-specific LAMP assays introduces a valuable new cost-effective tool for use in poultry husbandry. PMID:22053893

  6. The CD63 basophil activation test in Hymenoptera venom allergy: a prospective study.

    PubMed

    Sturm, G J; Böhm, E; Trummer, M; Weiglhofer, I; Heinemann, A; Aberer, W

    2004-10-01

    The basophil activation test (BAT), which relies on flow cytometric quantitation of the allergen-induced up-regulation of the granule-associated marker CD63 in peripheral blood basophils, has been suggested to be a useful approach in detecting responsiveness to allergens. The purpose of this study was to establish the usefulness of the BAT with regard to the clinical history and current diagnostic tools in Hymenoptera venom allergy using a prospective study design. Fifty-seven consecutive patients allergic to Hymenoptera venom as defined by a systemic reaction after an insect sting, and 30 age- and sex-matched control subjects with a negative history were included. The degree and nature of sensitization was confirmed by skin testing, specific immunoglobulin E (IgE), serum tryptase levels and BAT. In the nonallergic control group only analysis of specific IgE and BAT were performed. Correlation of BAT, skin test and specific IgE, respectively, with the clinical history in the allergic group was termed as sensitivity and in the control group as specificity. Twenty one of 23 (91.3%) bee venom allergic patients and 29 of 34 (85.3%) patients allergic to wasp and hornet venom tested positive in BAT. The overall sensitivity of BAT, specific IgE and skin tests were 87.7, 91.2 and 93.0%, respectively. The overall specificities were 86.7% for BAT and 66.7% for specific IgE. No correlation between the severity of clinical symptoms and the magnitude of basophil activation was observed. The BAT seems to be an appropriate method to identify patients allergic to bee or wasp venom with a comparable sensitivity to standard diagnostic regimens. The higher specificity of BAT as compared with specific IgE makes this test a useful tool in the diagnosis of Hymenoptera venom allergy.

  7. Bilingual Children's Performance on Three Nonword Repetition Tasks: The Role of Language Experience and Ability

    ERIC Educational Resources Information Center

    Huls, Simone

    2017-01-01

    Nonword repetition (NWR) tasks represent one assessment tool for Specific Language Impairment (SLI). The use of such tasks has been established and verified for monolingual children. However, the diagnostic accuracy of NWR tasks for bilingual children has had variable results and must address several unique characteristics of this population. Gaps…

  8. Avian cardiology.

    PubMed

    Strunk, Anneliese; Wilson, G Heather

    2003-01-01

    The field of avian cardiology is continually expanding. Although a great deal of the current knowledge base has been derived from poultry data, research and clinical reports involving companion avian species have been published. This article will present avian cardiovascular anatomy and physiology, history and physical examination considerations in the avian cardiac disease patient, specific diagnostic tools, cardiovascular disease processes, and current therapeutic modalities.

  9. Investigating the Clinical Usefulness of the Social Responsiveness Scale (SRS) in a Tertiary Level, Autism Spectrum Disorder Specific Assessment Clinic

    ERIC Educational Resources Information Center

    Aldridge, Fiona J.; Gibbs, Vicki M.; Schmidhofer, Katherine; Williams, Megan

    2012-01-01

    The Social Responsiveness Scale (SRS; Constantino and Gruber in Social Responsiveness Scale (SRS). Western Psychological Services, Los Angeles, 2005) is a commonly used screening tool for identifying children with possible autism spectrum disorder (ASD). This study investigated the relationship between SRS scores and eventual diagnostic outcome…

  10. Diagnosing clean margins through Raman spectroscopy in human and animal mammary tumour surgery: a short review

    PubMed Central

    Birtoiu, I. A.; Rizea, C.; Togoe, D.; Munteanu, R. M.; Micsa, C.; Rusu, M. I.; Tautan, M.; Braic, L.; Scoicaru, L. O.; Parau, A.; Becherescu-Barbu, N. D.; Udrea, M. V.; Tonetto, A.; Notonier, R.

    2016-01-01

    Breast cancer frequency in human and other mammal female populations has worryingly increased lately. The acute necessity for taxonomy of the aetiological factors along with seeking for new diagnostic tools and therapy procedures aimed at reducing mortality have yielded in an intense research effort worldwide. Surgery is a regular method to counteract extensive development of breast cancer and prevent metastases provided that negative surgical margins are achieved. This highly technical challenge requires fast, extremely sensitive and selective discrimination between malignant and benign tissues even down to molecular level. The particular advantages of Raman spectroscopy, such as high chemical specificity, and the ability to measure raw samples and optical responses in the visible or near-infrared spectral range, have recently recommended it as a means with elevated potential in precise diagnostic in oncology surgery. This review spans mainly the latter 10 years of exceptional efforts of scientists implementing Raman spectroscopy as a nearly real-time diagnostic tool for clean margins assessment in mastectomy and lumpectomy. Although greatly contributing to medical discoveries for the wealth of humanity, animals as patients have benefitted less from advances in surgery diagnostic using Raman spectroscopy. This work also dedicates a few lines to applications of surface enhanced Raman spectroscopy in veterinary oncological surgery. PMID:27920899

  11. FNA diagnostic value in patients with neck masses in two teaching hospitals in Iran.

    PubMed

    Saatian, Minoo; Badie, Banafsheh Moradmand; Shahriari, Sogol; Fattahi, Fahimeh; Rasoolinejad, Mehrnaz

    2011-01-01

    The FNA (fine needle aspiration) procedure is simple, inexpensive, available and a safe method for the diagnosis of a neck mass. FNA has numerous advantages over open surgical biopsies as an initial diagnostic tool; therefore we decided to compare the accuracy of this method with open biopsy. This retrospective as well as descriptive study comparing preoperative FNA results with existing data in the Pathology Department in Bu-Ali and Amir Alam Hospitals. Our study included 100 patients with neck masses of which 22 were thyroid masses, 31 were salivary gland masses, and 47 were other masses. Age ranged from 3 years to 80 years with the mean age of 42.6 years. There were 59 men and 41 women. The Sensitivity was 72%, Specificity 87%, PPV 85%, NPV 75% and diagnostic Accuracy 79%. In this study we had also 26% false negative and 15% false positive. FNA is a valuable diagnostic tool in the management of neck masses; also it has been used for staging and planning of treatment for the wide and metastatic malignancy. This technique reduces the need for more invasive and costly procedures. According to the high sensitivity and high accuracy in this study, FNA can be used as the first step of diagnoses test in neck masses.

  12. Future of diagnostic microbiology.

    PubMed

    Khardori, N

    2014-01-01

    Diagnostic Microbiology is the tool that makes it possible to identify the exact etiology of infectious diseases and the most optimal therapy at the level of individual patients as well as communities. Conventional methods require time to grow the microbes in vitro under specific conditions and not all microbes are easily cultivable. This is followed by biochemical methods for identification which also require hours and sometimes days. Transport of the specimens under less than ideal conditions, prior use of antibiotics and small number of organisms are among the factors that render culture-based methods less reliable. Newer methods depend on amplification of nucleic acids followed by use of probes for identification. This mitigates the need for higher microbial load, presence of metabolically active viable organisms and shortens the time to reporting. These methods can be used to detect antibiotic resistance genes directly from the specimen and help direct targeted therapy. Since these methods will not fulfill all the diagnostic needs, a second approach is being used to shorten the time to identification after the organism has already grown. Mass spectrometry and bioinformatics are the tools making this possible. This review gives a historical perspective on diagnostic microbiology, discusses the pitfalls of current methodology and provides an overview of newer and future methods.

  13. Interferometric Reflectance Imaging Sensor (IRIS)—A Platform Technology for Multiplexed Diagnostics and Digital Detection

    PubMed Central

    Avci, Oguzhan; Lortlar Ünlü, Nese; Yalçın Özkumur, Ayça; Ünlü, M. Selim

    2015-01-01

    Over the last decade, the growing need in disease diagnostics has stimulated rapid development of new technologies with unprecedented capabilities. Recent emerging infectious diseases and epidemics have revealed the shortcomings of existing diagnostics tools, and the necessity for further improvements. Optical biosensors can lay the foundations for future generation diagnostics by providing means to detect biomarkers in a highly sensitive, specific, quantitative and multiplexed fashion. Here, we review an optical sensing technology, Interferometric Reflectance Imaging Sensor (IRIS), and the relevant features of this multifunctional platform for quantitative, label-free and dynamic detection. We discuss two distinct modalities for IRIS: (i) low-magnification (ensemble biomolecular mass measurements) and (ii) high-magnification (digital detection of individual nanoparticles) along with their applications, including label-free detection of multiplexed protein chips, measurement of single nucleotide polymorphism, quantification of transcription factor DNA binding, and high sensitivity digital sensing and characterization of nanoparticles and viruses. PMID:26205273

  14. Diagnostic accuracy of scapular physical examination tests for shoulder disorders: a systematic review.

    PubMed

    Wright, Alexis A; Wassinger, Craig A; Frank, Mason; Michener, Lori A; Hegedus, Eric J

    2013-09-01

    To systematically review and critique the evidence regarding the diagnostic accuracy of physical examination tests for the scapula in patients with shoulder disorders. A systematic, computerised literature search of PubMED, EMBASE, CINAHL and the Cochrane Library databases (from database inception through January 2012) using keywords related to diagnostic accuracy of physical examination tests of the scapula. The Quality Assessment of Diagnostic Accuracy Studies tool was used to critique the quality of each paper. Eight articles met the inclusion criteria; three were considered to be of high quality. Of the three high-quality studies, two were in reference to a 'diagnosis' of shoulder pain. Only one high-quality article referenced specific shoulder pathology of acromioclavicular dislocation with reported sensitivity of 71% and 41% for the scapular dyskinesis and SICK scapula test, respectively. Overall, no physical examination test of the scapula was found to be useful in differentially diagnosing pathologies of the shoulder.

  15. The Microbial Detection Array Combined with Random Phi29-Amplification Used as a Diagnostic Tool for Virus Detection in Clinical Samples

    PubMed Central

    Erlandsson, Lena; Rosenstierne, Maiken W.; McLoughlin, Kevin; Jaing, Crystal; Fomsgaard, Anders

    2011-01-01

    A common technique used for sensitive and specific diagnostic virus detection in clinical samples is PCR that can identify one or several viruses in one assay. However, a diagnostic microarray containing probes for all human pathogens could replace hundreds of individual PCR-reactions and remove the need for a clear clinical hypothesis regarding a suspected pathogen. We have established such a diagnostic platform for random amplification and subsequent microarray identification of viral pathogens in clinical samples. We show that Phi29 polymerase-amplification of a diverse set of clinical samples generates enough viral material for successful identification by the Microbial Detection Array, demonstrating the potential of the microarray technique for broad-spectrum pathogen detection. We conclude that this method detects both DNA and RNA virus, present in the same sample, as well as differentiates between different virus subtypes. We propose this assay for diagnostic analysis of viruses in clinical samples. PMID:21853040

  16. Design and development of a simple UV fluorescence multi-spectral imaging system

    NASA Astrophysics Data System (ADS)

    Tovar, Carlos; Coker, Zachary; Yakovlev, Vladislav V.

    2018-02-01

    Healthcare access in low-resource settings is compromised by the availability of affordable and accurate diagnostic equipment. The four primary poverty-related diseases - AIDS, pneumonia, malaria, and tuberculosis - account for approximately 400 million annual deaths worldwide as of 2016 estimates. Current diagnostic procedures for these diseases are prolonged and can become unreliable under various conditions. We present the development of a simple low-cost UV fluorescence multi-spectral imaging system geared towards low resource settings for a variety of biological and in-vitro applications. Fluorescence microscopy serves as a useful diagnostic indicator and imaging tool. The addition of a multi-spectral imaging modality allows for the detection of fluorophores within specific wavelength bands, as well as the distinction between fluorophores possessing overlapping spectra. The developed instrument has the potential for a very diverse range of diagnostic applications in basic biomedical science and biomedical diagnostics and imaging. Performance assessment of the microscope will be validated with a variety of samples ranging from organic compounds to biological samples.

  17. Traumatic Brain Injury Detection Using Electrophysiological Methods

    PubMed Central

    Rapp, Paul E.; Keyser, David O.; Albano, Alfonso; Hernandez, Rene; Gibson, Douglas B.; Zambon, Robert A.; Hairston, W. David; Hughes, John D.; Krystal, Andrew; Nichols, Andrew S.

    2015-01-01

    Measuring neuronal activity with electrophysiological methods may be useful in detecting neurological dysfunctions, such as mild traumatic brain injury (mTBI). This approach may be particularly valuable for rapid detection in at-risk populations including military service members and athletes. Electrophysiological methods, such as quantitative electroencephalography (qEEG) and recording event-related potentials (ERPs) may be promising; however, the field is nascent and significant controversy exists on the efficacy and accuracy of the approaches as diagnostic tools. For example, the specific measures derived from an electroencephalogram (EEG) that are most suitable as markers of dysfunction have not been clearly established. A study was conducted to summarize and evaluate the statistical rigor of evidence on the overall utility of qEEG as an mTBI detection tool. The analysis evaluated qEEG measures/parameters that may be most suitable as fieldable diagnostic tools, identified other types of EEG measures and analysis methods of promise, recommended specific measures and analysis methods for further development as mTBI detection tools, identified research gaps in the field, and recommended future research and development thrust areas. The qEEG study group formed the following conclusions: (1) Individual qEEG measures provide limited diagnostic utility for mTBI. However, many measures can be important features of qEEG discriminant functions, which do show significant promise as mTBI detection tools. (2) ERPs offer utility in mTBI detection. In fact, evidence indicates that ERPs can identify abnormalities in cases where EEGs alone are non-disclosing. (3) The standard mathematical procedures used in the characterization of mTBI EEGs should be expanded to incorporate newer methods of analysis including non-linear dynamical analysis, complexity measures, analysis of causal interactions, graph theory, and information dynamics. (4) Reports of high specificity in qEEG evaluations of TBI must be interpreted with care. High specificities have been reported in carefully constructed clinical studies in which healthy controls were compared against a carefully selected TBI population. The published literature indicates, however, that similar abnormalities in qEEG measures are observed in other neuropsychiatric disorders. While it may be possible to distinguish a clinical patient from a healthy control participant with this technology, these measures are unlikely to discriminate between, for example, major depressive disorder, bipolar disorder, or TBI. The specificities observed in these clinical studies may well be lost in real world clinical practice. (5) The absence of specificity does not preclude clinical utility. The possibility of use as a longitudinal measure of treatment response remains. However, efficacy as a longitudinal clinical measure does require acceptable test–retest reliability. To date, very few test–retest reliability studies have been published with qEEG data obtained from TBI patients or from healthy controls. This is a particular concern because high variability is a known characteristic of the injured central nervous system. PMID:25698950

  18. Traumatic brain injury detection using electrophysiological methods.

    PubMed

    Rapp, Paul E; Keyser, David O; Albano, Alfonso; Hernandez, Rene; Gibson, Douglas B; Zambon, Robert A; Hairston, W David; Hughes, John D; Krystal, Andrew; Nichols, Andrew S

    2015-01-01

    Measuring neuronal activity with electrophysiological methods may be useful in detecting neurological dysfunctions, such as mild traumatic brain injury (mTBI). This approach may be particularly valuable for rapid detection in at-risk populations including military service members and athletes. Electrophysiological methods, such as quantitative electroencephalography (qEEG) and recording event-related potentials (ERPs) may be promising; however, the field is nascent and significant controversy exists on the efficacy and accuracy of the approaches as diagnostic tools. For example, the specific measures derived from an electroencephalogram (EEG) that are most suitable as markers of dysfunction have not been clearly established. A study was conducted to summarize and evaluate the statistical rigor of evidence on the overall utility of qEEG as an mTBI detection tool. The analysis evaluated qEEG measures/parameters that may be most suitable as fieldable diagnostic tools, identified other types of EEG measures and analysis methods of promise, recommended specific measures and analysis methods for further development as mTBI detection tools, identified research gaps in the field, and recommended future research and development thrust areas. The qEEG study group formed the following conclusions: (1) Individual qEEG measures provide limited diagnostic utility for mTBI. However, many measures can be important features of qEEG discriminant functions, which do show significant promise as mTBI detection tools. (2) ERPs offer utility in mTBI detection. In fact, evidence indicates that ERPs can identify abnormalities in cases where EEGs alone are non-disclosing. (3) The standard mathematical procedures used in the characterization of mTBI EEGs should be expanded to incorporate newer methods of analysis including non-linear dynamical analysis, complexity measures, analysis of causal interactions, graph theory, and information dynamics. (4) Reports of high specificity in qEEG evaluations of TBI must be interpreted with care. High specificities have been reported in carefully constructed clinical studies in which healthy controls were compared against a carefully selected TBI population. The published literature indicates, however, that similar abnormalities in qEEG measures are observed in other neuropsychiatric disorders. While it may be possible to distinguish a clinical patient from a healthy control participant with this technology, these measures are unlikely to discriminate between, for example, major depressive disorder, bipolar disorder, or TBI. The specificities observed in these clinical studies may well be lost in real world clinical practice. (5) The absence of specificity does not preclude clinical utility. The possibility of use as a longitudinal measure of treatment response remains. However, efficacy as a longitudinal clinical measure does require acceptable test-retest reliability. To date, very few test-retest reliability studies have been published with qEEG data obtained from TBI patients or from healthy controls. This is a particular concern because high variability is a known characteristic of the injured central nervous system.

  19. The application of genome-wide 5-hydroxymethylcytosine studies in cancer research.

    PubMed

    Thomson, John P; Meehan, Richard R

    2017-01-01

    Early detection and characterization of molecular events associated with tumorgenesis remain high priorities. Genome-wide epigenetic assays are promising diagnostic tools, as aberrant epigenetic events are frequent and often cancer specific. The deposition and analysis of multiple patient-derived cancer epigenomic profiles contributes to our appreciation of the underlying biology; aiding the detection of novel identifiers for cancer subtypes. Modifying enzymes and co-factors regulating these epigenetic marks are frequently mutated in cancers, and as epigenetic modifications themselves are reversible, this makes their study very attractive with respect to pharmaceutical intervention. Here we focus on the novel modified base, 5-hydoxymethylcytosine, and discuss how genome-wide 5-hydoxymethylcytosine profiling expedites our molecular understanding of cancer, serves as a lineage tracer, classifies the mode of action of potentially carcinogenic agents and clarifies the roles of potential novel cancer drug targets; thus assisting the development of new diagnostic/prognostic tools.

  20. Toward fish and seafood traceability: anchovy species determination in fish products by molecular markers and support through a public domain database.

    PubMed

    Jérôme, Marc; Martinsohn, Jann Thorsten; Ortega, Delphine; Carreau, Philippe; Verrez-Bagnis, Véronique; Mouchel, Olivier

    2008-05-28

    Traceability in the fish food sector plays an increasingly important role for consumer protection and confidence building. This is reflected by the introduction of legislation and rules covering traceability on national and international levels. Although traceability through labeling is well established and supported by respective regulations, monitoring and enforcement of these rules are still hampered by the lack of efficient diagnostic tools. We describe protocols using a direct sequencing method based on 212-274-bp diagnostic sequences derived from species-specific mitochondria DNA cytochrome b, 16S rRNA, and cytochrome oxidase subunit I sequences which can efficiently be applied to unambiguously determine even closely related fish species in processed food products labeled "anchovy". Traceability of anchovy-labeled products is supported by the public online database AnchovyID ( http://anchovyid.jrc.ec.europa.eu), which provided data obtained during our study and tools for analytical purposes.

  1. Using cluster ensemble and validation to identify subtypes of pervasive developmental disorders.

    PubMed

    Shen, Jess J; Lee, Phil-Hyoun; Holden, Jeanette J A; Shatkay, Hagit

    2007-10-11

    Pervasive Developmental Disorders (PDD) are neurodevelopmental disorders characterized by impairments in social interaction, communication and behavior. Given the diversity and varying severity of PDD, diagnostic tools attempt to identify homogeneous subtypes within PDD. Identifying subtypes can lead to targeted etiology studies and to effective type-specific intervention. Cluster analysis can suggest coherent subsets in data; however, different methods and assumptions lead to different results. Several previous studies applied clustering to PDD data, varying in number and characteristics of the produced subtypes. Most studies used a relatively small dataset (fewer than 150 subjects), and all applied only a single clustering method. Here we study a relatively large dataset (358 PDD patients), using an ensemble of three clustering methods. The results are evaluated using several validation methods, and consolidated through an integration step. Four clusters are identified, analyzed and compared to subtypes previously defined by the widely used diagnostic tool DSM-IV.

  2. Using Cluster Ensemble and Validation to Identify Subtypes of Pervasive Developmental Disorders

    PubMed Central

    Shen, Jess J.; Lee, Phil Hyoun; Holden, Jeanette J.A.; Shatkay, Hagit

    2007-01-01

    Pervasive Developmental Disorders (PDD) are neurodevelopmental disorders characterized by impairments in social interaction, communication and behavior.1 Given the diversity and varying severity of PDD, diagnostic tools attempt to identify homogeneous subtypes within PDD. Identifying subtypes can lead to targeted etiology studies and to effective type-specific intervention. Cluster analysis can suggest coherent subsets in data; however, different methods and assumptions lead to different results. Several previous studies applied clustering to PDD data, varying in number and characteristics of the produced subtypes19. Most studies used a relatively small dataset (fewer than 150 subjects), and all applied only a single clustering method. Here we study a relatively large dataset (358 PDD patients), using an ensemble of three clustering methods. The results are evaluated using several validation methods, and consolidated through an integration step. Four clusters are identified, analyzed and compared to subtypes previously defined by the widely used diagnostic tool DSM-IV.2 PMID:18693920

  3. Advances in genetics and genomics: use and limitations in achieving malaria elimination goals

    PubMed Central

    Gunawardena, Sharmini; Karunaweera, Nadira D.

    2015-01-01

    Success of the global research agenda towards eradication of malaria will depend on the development of new tools, including drugs, vaccines, insecticides and diagnostics. Genetic and genomic information now available for the malaria parasites, their mosquito vectors and human host, can be harnessed to both develop these tools and monitor their effectiveness. Here we review and provide specific examples of current technological advances and how these genetic and genomic tools have increased our knowledge of host, parasite and vector biology in relation to malaria elimination and in turn enhanced the potential to reach that goal. We then discuss limitations of these tools and future prospects for the successful achievement of global malaria elimination goals. PMID:25943157

  4. An international comparative family medicine study of the Transition Project data from the Netherlands, Malta and Serbia. Is family medicine an international discipline? Comparing diagnostic odds ratios across populations.

    PubMed

    Soler, Jean K; Okkes, Inge; Oskam, Sibo; van Boven, Kees; Zivotic, Predrag; Jevtic, Milan; Dobbs, Frank; Lamberts, Henk

    2012-06-01

    This is an international study of the epidemiology of family medicine (FM) in three practice populations from the Netherlands, Malta and Serbia. Diagnostic associations between common reasons for encounter (RfEs) and episodes titles are compared and similarities and differences are described and analysed. Participating family doctors (FDs) recorded details of all their patient contacts in an 'episode of care (EoC)' structure using the International Classification of Primary Care (ICPC). RfEs presented by the patient and episode titles (diagnostic labels of EoCs) were classified with ICPC. The relationships between RfEs and episode titles were studied with Bayesian methods. Distributions of diagnostic odds ratios (ORs) from the three population databases are presented and compared. ICPC, the RfE and the EoC data model are appropriate tools to study the process of diagnosis in FM. Distributions of diagnostic associations between RfEs and episode titles in the Transition Project international populations show remarkable similarities and congruencies in the process of diagnosis from both the RfE and the episode title perspectives. The congruence of diagnostic associations between populations supports the use of such data from one population to inform diagnostic decisions in another. Differences in the magnitude of such diagnostic associations are significant, and population-specific data are therefore desirable. We propose that both an international (common) and a local (health care system specific) content of FM exist and that the empirical distributions of diagnostic associations presented in this paper are a reflection of both these effects. We also observed that the frequency of exposure to such diagnostic challenges had a strong effect on the confidence intervals of diagnostic ORs reflecting these diagnostic associations. We propose that this constitutes evidence that expertise in FM is associated with frequency of exposure to diagnostic challenges.

  5. Thoracic radiography in the cat: Identification of cardiomegaly and congestive heart failure.

    PubMed

    Guglielmini, Carlo; Diana, Alessia

    2015-12-01

    Thoracic radiography is one of the most commonly employed diagnostic tools for the clinical evaluation of cats with suspected heart disease and is the standard diagnostic method in the confirmation of cardiogenic pulmonary edema. In the past, interpretation of feline radiographs focused on a description of the qualitative radiographic features of feline heart disease or the measurement of the cardiac silhouette in healthy cats and cats with different cardiovascular disorders. More recently, studies have begun to critically address the issue of the diagnostic accuracy of thoracic radiography in the diagnostic work-up of cats with heart disease. In these studies, qualitative and quantitative radiographic parameters were compared to echocardiographic findings to evaluate the usefulness of thoracic radiography for the identification of cardiac enlargement and pulmonary edema in the cat. Thoracic radiography is reasonably specific but has a low sensitivity when identifying cardiomegaly in cats with mild structural heart disease. Feline cardiogenic pulmonary edema has a variable radiographic presentation and several specific radiographic findings (i.e., enlargement of the left atrium and the pulmonary veins) can be absent or non-recognizable in affected cats. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. The comparative accuracy of rapid diagnostic test with microscopy to diagnose malaria in subdistrict lima puluh batubara regency North Sumatera province

    NASA Astrophysics Data System (ADS)

    Rezeki, S.; Pasaribu, A. P.

    2018-03-01

    Indonesia is the country where malaria is still the most common population problem. The high rate of mortality and morbidity occurred due to delays in diagnosis whichis strongly influenced by the availability of diagnostic tools and personnel with required laboratory skill. This diagnostic study aims to compare the accuracy of a Rapid Diagnostic Test (RDT) without skill requirement, to agold standard microscopic method for malaria diagnosis. The study was conducted in Subdistrict Lima Puluh North Sumatera Province from December 2015 to January 2016. The subject was taken cross-sectionally from a population with characteristics typically found in malaria patients in Subdistrict Lima Puluh. The result showed a sensitivity of 100% and a specificity of 72.4% with a positive predictive value of 89.9% and a negative predictive value of 100%; the negative likelihood ratio is 0 and the positive likelihood ratio of 27.6 for Parascreen. This research indicates that Parascreen had a high sensitivity and specificity and may be consideredas an alternative for the diagnosis of malaria in Subdistrict Lima Puluh North Sumatera Province especially in areas where no skilled microscopist is available.

  7. Systematic review of fall risk screening tools for older patients in acute hospitals.

    PubMed

    Matarese, Maria; Ivziku, Dhurata; Bartolozzi, Francesco; Piredda, Michela; De Marinis, Maria Grazia

    2015-06-01

    To determine the most accurate fall risk screening tools for predicting falls among patients aged 65 years or older admitted to acute care hospitals. Falls represent a serious problem in older inpatients due to the potential physical, social, psychological and economic consequences. Older inpatients present with risk factors associated with age-related physiological and psychological changes as well as multiple morbidities. Thus, fall risk screening tools for older adults should include these specific risk factors. There are no published recommendations addressing what tools are appropriate for older hospitalized adults. Systematic review. MEDLINE, CINAHL and Cochrane electronic databases were searched between January 1981-April 2013. Only prospective validation studies reporting sensitivity and specificity values were included. Recommendations of the Cochrane Handbook of Diagnostic Test Accuracy Reviews have been followed. Three fall risk assessment tools were evaluated in seven articles. Due to the limited number of studies, meta-analysis was carried out only for the STRATIFY and Hendrich Fall Risk Model II. In the combined analysis, the Hendrich Fall Risk Model II demonstrated higher sensitivity than STRATIFY, while the STRATIFY showed higher specificity. In both tools, the Youden index showed low prognostic accuracy. The identified tools do not demonstrate predictive values as high as needed for identifying older inpatients at risk for falls. For this reason, no tool can be recommended for fall detection. More research is needed to evaluate fall risk screening tools for older inpatients. © 2014 John Wiley & Sons Ltd.

  8. Development and application of air quality models at the US ...

    EPA Pesticide Factsheets

    Overview of the development and application of air quality models at the U.S. EPA, particularly focused on the development and application of the Community Multiscale Air Quality (CMAQ) model developed within the Computation Exposure Division (CED) of the National Exposure Research Laboratory (NERL). This presentation will provide a simple overview of air quality model development and application geared toward a non-technical student audience. The National Exposure Research Laboratory (NERL) Computational Exposure Division (CED) develops and evaluates data, decision-support tools, and models to be applied to media-specific or receptor-specific problem areas. CED uses modeling-based approaches to characterize exposures, evaluate fate and transport, and support environmental diagnostics/forensics with input from multiple data sources. It also develops media- and receptor-specific models, process models, and decision support tools for use both within and outside of EPA.

  9. Autism detection in early childhood (ADEC): reliability and validity data for a Level 2 screening tool for autistic disorder.

    PubMed

    Nah, Yong-Hwee; Young, Robyn L; Brewer, Neil; Berlingeri, Genna

    2014-03-01

    The Autism Detection in Early Childhood (ADEC; Young, 2007) was developed as a Level 2 clinician-administered autistic disorder (AD) screening tool that was time-efficient, suitable for children under 3 years, easy to administer, and suitable for persons with minimal training and experience with AD. A best estimate clinical Diagnostic and Statistical Manual of Mental Disorders (4th ed., text rev.; DSM-IV-TR; American Psychiatric Association, 2000) diagnosis of AD was made for 70 children using all available information and assessment results, except for the ADEC data. A screening study compared these children on the ADEC with 57 children with other developmental disorders and 64 typically developing children. Results indicated high internal consistency (α = .91). Interrater reliability and test-retest reliability of the ADEC were also adequate. ADEC scores reliably discriminated different diagnostic groups after controlling for nonverbal IQ and Vineland Adaptive Behavior Composite scores. Construct validity (using exploratory factor analysis) and concurrent validity using performance on the Autism Diagnostic Observation Schedule (Lord et al., 2000), the Autism Diagnostic Interview-Revised (Le Couteur, Lord, & Rutter, 2003), and DSM-IV-TR criteria were also demonstrated. Signal detection analysis identified the optimal ADEC cutoff score, with the ADEC identifying all children who had an AD (N = 70, sensitivity = 1.0) but overincluding children with other disabilities (N = 13, specificity ranging from .74 to .90). Together, the reliability and validity data indicate that the ADEC has potential to be established as a suitable and efficient screening tool for infants with AD. 2014 APA

  10. Nested PCR Assay for Eight Pathogens: A Rapid Tool for Diagnosis of Bacterial Meningitis.

    PubMed

    Bhagchandani, Sharda P; Kubade, Sushant; Nikhare, Priyanka P; Manke, Sonali; Chandak, Nitin H; Kabra, Dinesh; Baheti, Neeraj N; Agrawal, Vijay S; Sarda, Pankaj; Mahajan, Parikshit; Ganjre, Ashish; Purohit, Hemant J; Singh, Lokendra; Taori, Girdhar M; Daginawala, Hatim F; Kashyap, Rajpal S

    2016-02-01

    Bacterial meningitis is a dreadful infectious disease with a high mortality and morbidity if remained undiagnosed. Traditional diagnostic methods for bacterial meningitis pose a challenge in accurate identification of pathogen, making prognosis difficult. The present study is therefore aimed to design and evaluate a specific and sensitive nested 16S rDNA genus-based polymerase chain reaction (PCR) assay using clinical cerebrospinal fluid (CSF) for rapid diagnosis of eight pathogens causing the disease. The present work was dedicated to development of an in-house genus specific 16S rDNA nested PCR covering pathogens of eight genera responsible for causing bacterial meningitis using newly designed as well as literature based primers for respective genus. A total 150 suspected meningitis CSF obtained from the patients admitted to Central India Institute of Medical Sciences (CIIMS), India during the period from August 2011 to May 2014, were used to evaluate clinical sensitivity and clinical specificity of optimized PCR assays. The analytical sensitivity and specificity of our newly designed genus-specific 16S rDNA PCR were found to be ≥92%. With such a high sensitivity and specificity, our in-house nested PCR was able to give 100% sensitivity in clinically confirmed positive cases and 100% specificity in clinically confirmed negative cases indicating its applicability in clinical diagnosis. Our in-house nested PCR system therefore can diagnose the accurate pathogen causing bacterial meningitis and therefore be useful in selecting a specific treatment line to minimize morbidity. Results are obtained within 24 h and high sensitivity makes this nested PCR assay a rapid and accurate diagnostic tool compared to traditional culture-based methods.

  11. [Clinical applications of molecular imaging methods for patients with ischemic stroke].

    PubMed

    Yamauchi, Hiroshi; Fukuyama, Hidenao

    2007-02-01

    Several molecular imaging methods have been developed to visualize pathophysiology of cerebral ischemia in humans in vivo. PET and SPECT with specific ligands have been mainly used as diagnostic tools for the clinical usage of molecular imaging in patients with ischemic stroke. Recently, cellular MR imaging with specific contrast agents has been developed to visualize targeted cells in human stroke patients. This article reviews the current status in the clinical applications of those molecular imaging methods for patients with ischemic stroke.

  12. Reporting completeness and transparency of meta-analyses of depression screening tool accuracy: A comparison of meta-analyses published before and after the PRISMA statement.

    PubMed

    Rice, Danielle B; Kloda, Lorie A; Shrier, Ian; Thombs, Brett D

    2016-08-01

    Meta-analyses that are conducted rigorously and reported completely and transparently can provide accurate evidence to inform the best possible healthcare decisions. Guideline makers have raised concerns about the utility of existing evidence on the diagnostic accuracy of depression screening tools. The objective of our study was to evaluate the transparency and completeness of reporting in meta-analyses of the diagnostic accuracy of depression screening tools using the PRISMA tool adapted for diagnostic test accuracy meta-analyses. We searched MEDLINE and PsycINFO from January 1, 2005 through March 13, 2016 for recent meta-analyses in any language on the diagnostic accuracy of depression screening tools. Two reviewers independently assessed the transparency in reporting using the PRISMA tool with appropriate adaptations made for studies of diagnostic test accuracy. We identified 21 eligible meta-analyses. Twelve of 21 meta-analyses complied with at least 50% of adapted PRISMA items. Of 30 adapted PRISMA items, 11 were fulfilled by ≥80% of included meta-analyses, 3 by 50-79% of meta-analyses, 7 by 25-45% of meta-analyses, and 9 by <25%. On average, post-PRISMA meta-analyses complied with 17 of 30 items compared to 13 of 30 items pre-PRISMA. Deficiencies in the transparency of reporting in meta-analyses of the diagnostic test accuracy of depression screening tools of meta-analyses were identified. Authors, reviewers, and editors should adhere to the PRISMA statement to improve the reporting of meta-analyses of the diagnostic accuracy of depression screening tools. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Predictive Ability of an Emergency Medical Dispatch Stroke Diagnostic Tool in Identifying Hospital-Confirmed Strokes.

    PubMed

    Clawson, Jeff J; Scott, Greg; Gardett, Isabel; Youngquist, Scott; Taillac, Peter; Fivaz, Conrad; Olola, Christopher

    2016-08-01

    Early hospital notification of a possible stroke arriving via emergency medical services (EMS) can prepare stroke center personnel for timely treatment, especially timely administration of tissue plasminogen activator. Stroke center notification from the emergency dispatch center-before responders reach the scene-may promote even earlier and faster system activation, meaning that stroke center teams may be ready to receive patients as soon as the ambulance arrives. This study evaluates the use of a Medical Priority Dispatch System (MPDS; Priority Dispatch Corp., Salt Lake City, UT) Stroke Diagnostic Tool (SDxT) to identify possible strokes early by comparing the tools' results to on-scene and hospital findings. The retrospective descriptive study utilized stroke data from 3 sources: emergency medical dispatch, EMS, and emergency department/hospital. A total of 830 cases were collected between June 2012 and December 2013, of which 603 (72.7%) had matching dispatch records. Of the 603 cases, 304 (50.4%) were handled using MPDS Stroke Protocol 28. The SDxT had an 86.4% ability (OR [95% CI]: 2.3 [1.5, 3.5]) to effectively identify strokes among all the hospital-confirmed stroke cases (sensitivity), and a 26.6% ability to effectively identify nonstrokes among all the hospital-confirmed nonstroke cases (specificity). The SDxT demonstrated a very high sensitivity, compared to similar tools used in the field and at dispatch. The specificity was somewhat low, but this was expected-and is intended in the creation of protocols to be used over the phone in emergency situations. The tool is a valuable method for identifying strokes early and may allow early hospital notification. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  14. Diagnostic accuracy of HLA-B*57:01 screening for the prediction of abacavir hypersensitivity and clinical utility of the test: a meta-analytic review.

    PubMed

    Cargnin, Sarah; Jommi, Claudio; Canonico, Pier Luigi; Genazzani, Armando A; Terrazzino, Salvatore

    2014-05-01

    To determine diagnostic accuracy of HLA-B*57:01 testing for prediction of abacavir-induced hypersensitivity and to quantify the clinical benefit of pretreatment screening through a meta-analytic review of published studies. A comprehensive search was performed up to June 2013. The methodological quality of relevant studies was assessed by the QUADAS-2 tool. The pooled diagnostic estimates were calculated using a random effect model. Despite the presence of heterogeneity in sensitivity or specificity estimates, the pooled diagnostic odds ratio to detect abacavir-induced hypersensitivity on the basis of clinical criteria was 33.07 (95% CI: 22.33-48.97, I(2): 13.9%), while diagnostic odds ratio for detection of immunologically confirmed abacavir hypersensitivity was 1141 (95% CI: 409-3181, I(2): 0%). Pooled analysis of risk ratio showed that prospective HLA-B*57:01 testing significantly reduced the incidence of abacavir-induced hypersensitivity. This meta-analysis demonstrates an excellent diagnostic accuracy of HLA-B*57:01 testing to detect immunologically confirmed abacavir hypersensitivity and corroborates existing recommendations.

  15. Diagnostic performance of rapid diagnostic tests for the diagnosis of malaria at public health facilities in north-west Ethiopia.

    PubMed

    Getnet, Gebeyaw; Getie, Sisay; Srivastava, Mitaly; Birhan, Wubet; Fola, Abebe A; Noedl, Harald

    2015-11-01

    To assess the performance of RDTs against nested polymerase chain reaction (nPCR) for the diagnosis of malaria in public health facilities in north-western Ethiopia. Cross-sectional study at public health facilities in North Gondar, Ethiopia, of 359 febrile patients with signs and symptoms consistent with malaria. Finger prick blood samples were collected for testing in a P. falciparum/pan-malaria RDTs and for molecular analysis. Sensitivity, specificity and predictive values were determined for the RDTs using nPCR as reference diagnostic method. Kappa value was determined to demonstrate the consistency of the results between the diagnostic tools. By RDTs, 22.28% (80/359) of patients tested positive for malaria, and by nPCR, 27.02% (97/359) did. In nPCR, 1.67% (6/359) and 0.28% (1/359) samples were positive for P. ovale and P. malariae, which had almost all tested negative in the RDTs. The sensitivity, specificity, positive and negative predictive values of RDTs for the diagnosis of malaria were 62.9%, 92.7%, 76.3% and 87.1%, respectively, with 0.589 measurement agreement between RDTs and nPCR. The sensitivity and specificity of RDTs for P. falciparum identification only were 70.8% and 95.2%, and 65.2% and 93.1% for P. vivax. Although RDTs are commonly used at health posts in resource-limited environments, their sensitivity and specificity for the detection and species identification of Plasmodium parasites were poor compared to nPCR, suggesting caution in interpreting RDTs results. Particularly, in the light of expanded efforts to eliminate malaria in the country, more sensitive diagnostic procedures will be needed. © 2015 John Wiley & Sons Ltd.

  16. The use of intrathecal analgesia and contrast radiography as preoperative diagnostic methods for digital flexor tendon sheath pathology.

    PubMed

    Fiske-Jackson, A R; Barker, W H J; Eliashar, E; Foy, K; Smith, R K W

    2013-01-01

    The sensitivity of ultrasonography for the diagnosis of manica flexoria (MF) tears within the digital flexor tendon sheath (DFTS) is lower than for diagnosis of marginal tears of the deep digital flexor tendon (DDFT). Additional diagnostic tools would assist in appropriate decision making for either conservative or surgical management. To evaluate the improvement in lameness of horses with MF or DDFT tears following intrathecal analgesia and to assess the sensitivity and specificity of contrast radiography for the diagnosis of these tears. The case records of horses presented to a referral clinic over a 7-year period that underwent intrathecal diagnostic analgesia, or intrathecal analgesia and contrast radiography, of the DFTS with subsequent tenoscopy were examined. Fifty-three limbs had intrathecal diagnostic analgesia performed and 23 contrast tenograms were assessed in horses undergoing DFTS tenoscopy. Horses with DDFT tears were significantly more likely to respond positively to intrathecal diagnostic analgesia than those with MF tears (P = 0.02). Using contrast radiography, tears of the MF were predicted with an overall sensitivity of 96% and specificity of 80%; marginal tears of the DDFT were predicted with an overall sensitivity of 57% and specificity of 84%. The results of intrathecal analgesia of the DFTS in combination with contrast radiography have a high sensitivity for predicting MF tears. The sensitivity of contrast radiography for predicting tears of the DDFT is lower but the specificity remains high. Contrast radiography performed at the same time as intrathecal analgesia provides useful information regarding the presence of MF tears and DDFT tears, which can assist in the decision of whether to manage the lameness conservatively or with tenoscopic evaluation. © 2012 EVJ Ltd.

  17. Usefulness of Four Different Echinococcus granulosus Recombinant Antigens for Serodiagnosis of Unilocular Hydatid Disease (UHD) and Postsurgical Follow-Up of Patients Treated for UHD▿

    PubMed Central

    Hernández-González, Ana; Muro, Antonio; Barrera, Inmaculada; Ramos, Guillermo; Orduña, Antonio; Siles-Lucas, Mar

    2008-01-01

    Four different recombinant antigens derived from Echinococcus granulosus, designated B1t, B2t, E14t, and C317, were tested with enzyme-linked immunosorbent assays (ELISAs) for the detection of specific immunoglobulin G (IgG) in patients with unilocular hydatid disease (UHD). The results were compared to those obtained with hydatid fluid and were subjected to receiver operator characteristic analysis. The diagnostic performance of the above-listed proteins was defined with respect to their specificity, sensitivity, and predictive values (PV); the influence of cyst location; and usefulness in the follow-up of surgical treatment for UHD and in the determination of whether or not patients have been surgically cured of UHD. The best diagnostic results were obtained with the anti-B2t IgG ELISA, with 91.2% sensitivity, 93% specificity, and high positive and negative PV (89.4 and 94.2, respectively). In addition, this diagnostic tool proved to be useful for the follow-up of surgically treated UHD patients. The anti-B2t IgG ELISA may find an application in the serodiagnosis of UHD in clinical laboratories. PMID:17989342

  18. Riems influenza a typing array (RITA): An RT-qPCR-based low density array for subtyping avian and mammalian influenza a viruses.

    PubMed

    Hoffmann, Bernd; Hoffmann, Donata; Henritzi, Dinah; Beer, Martin; Harder, Timm C

    2016-06-03

    Rapid and sensitive diagnostic approaches are of the utmost importance for the detection of humans and animals infected by specific influenza virus subtype(s). Cascade-like diagnostics starting with the use of pan-influenza assays and subsequent subtyping devices are normally used. Here, we demonstrated a novel low density array combining 32 TaqMan(®) real-time RT-PCR systems in parallel for the specific detection of the haemagglutinin (HA) and neuraminidase (NA) subtypes of avian and porcine hosts. The sensitivity of the newly developed system was compared with that of the pan-influenza assay, and the specificity of all RT-qPCRs was examined using a broad panel of 404 different influenza A virus isolates representing 45 different subtypes. Furthermore, we analysed the performance of the RT-qPCR assays with diagnostic samples obtained from wild birds and swine. Due to the open format of the array, adaptations to detect newly emerging influenza A virus strains can easily be integrated. The RITA array represents a competitive, fast and sensitive subtyping tool that requires neither new machinery nor additional training of staff in a lab where RT-qPCR is already established.

  19. Diagnostic value of using 18F-FDG PET and PET/CT in immunocompetent patients with primary central nervous system lymphoma: A systematic review and meta-analysis.

    PubMed

    Zou, Yaru; Tong, Jianjing; Leng, Haiyan; Jiang, Jingwei; Pan, Meng; Chen, Zi

    2017-06-20

    18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) and PET/CT have become two of the most powerful tools for malignant lymphoma exploration, but their diagnostic role in primary central nervous system lymphoma (PCNSL) is still disputed. The purpose of our study is to identify the usefulness of 18F-FDG PET and PET/CT for detecting PCNSL. A total of 129 patients, obtained from eight eligible studies, were included for this systematic review and meta-analysis. The performance of 18F-FDG PET and PET/CT for diagnosing PCNSL were as follows: the pooled sensitivity was 0.88 (95% CI: 0.80-0.94), specificity was 0.86 (95% CI: 0.73-0.94), positive likelihood ratio (PLR) was 3.99 (95% CI: 2.31-6.90), negative likelihood ratio (NLR) was 0.11 (95% CI: 0.04-0.32), and diagnostic odds ratio (DOR) was 33.40 (95% CI: 10.40-107.3). In addition, the area under the curve (AUC) and Q index were 0.9192 and 0.8525, respectively. PubMed/MEDLINE, Embase and Cochrane Library were systematically searched for potential publications (last updated on July 16th, 2016). Reference lists of included articles were also checked. Original articles that reported data on patients who were suspected of having PCNSL were considered suitable for inclusion. The sensitivities and specificities of 18F-FDG PET and PET/CT in each study were evaluated. The Stata software and Meta-Disc software were employed in the process of data analysis. 18F-FDG PET and PET/CT showed considerable accuracy in identifying PCNSL in immunocompetent patients and could be a valuable radiological diagnostic tool for PCNSL.

  20. Validation of Quantitative Multimodality Analysis of Telomerase Activity in Urine Cells as a Noninvasive Diagnostic and Prognostic Tool for Prostate Cancer

    DTIC Science & Technology

    2005-08-01

    present study, who was previously misdiagnosed with BPH and inflammation, eventually has revealed the prostate cancer with the Gleason score 7. Therefore...Noninvasive Diagnostic and Prognostic Tool for Prostate Cancer ...5a. CONTRACT NUMBER Urine Cells as a Noninvasive Diagnostic and Prognostic Tool for Prostate Cancer 5b. GRANT NUMBER W81XWH-04-1-0774 5c

  1. Analysis of laparoscopy in trauma.

    PubMed

    Villavicencio, R T; Aucar, J A

    1999-07-01

    The optimum roles for laparoscopy in trauma have yet to be established. To date, reviews of laparoscopy in trauma have been primarily descriptive rather than analytic. This article analyzes the results of laparoscopy in trauma. Outcome analysis was done by reviewing 37 studies with more than 1,900 trauma patients, and laparoscopy was analyzed as a screening, diagnostic, or therapeutic tool. Laparoscopy was regarded as a screening tool if it was used to detect or exclude a positive finding (eg, hemoperitoneum, organ injury, gastrointestinal spillage, peritoneal penetration) that required operative exploration or repair. Laparoscopy was regarded as a diagnostic tool when it was used to identify all injuries, rather than as a screening tool to identify the first indication for a laparotomy. It was regarded as a diagnostic tool only in studies that mandated a laparotomy (gold standard) after laparoscopy to confirm the diagnostic accuracy of laparoscopic findings. Costs and charges for using laparoscopy in trauma were analyzed when feasible. As a screening tool, laparoscopy missed 1% of injuries and helped prevent 63% of patients from having a trauma laparotomy. When used as a diagnostic tool, laparoscopy had a 41% to 77% missed injury rate per patient. Overall, laparoscopy carried a 1% procedure-related complication rate. Cost-effectiveness has not been uniformly proved in studies comparing laparoscopy and laparotomy. Laparoscopy has been applied safely and effectively as a screening tool in stable patients with acute trauma. Because of the large number of missed injuries when used as a diagnostic tool, its value in this context is limited. Laparoscopy has been reported infrequently as a therapeutic tool in selected patients, and its use in this context requires further study.

  2. Evaluating online diagnostic decision support tools for the clinical setting.

    PubMed

    Pryor, Marie; White, David; Potter, Bronwyn; Traill, Roger

    2012-01-01

    Clinical decision support tools available at the point of care are an effective adjunct to support clinicians to make clinical decisions and improve patient outcomes. We developed a methodology and applied it to evaluate commercially available online clinical diagnostic decision support (DDS) tools for use at the point of care. We identified 11 commercially available DDS tools and assessed these against an evaluation instrument that included 6 categories; general information, content, quality control, search, clinical results and other features. We developed diagnostically challenging clinical case scenarios based on real patient experience that were commonly missed by junior medical staff. The evaluation was divided into 2 phases; an initial evaluation of all identified and accessible DDS tools conducted by the Clinical Information Access Portal (CIAP) team and a second phase that further assessed the top 3 tools identified in the initial evaluation phase. An evaluation panel consisting of senior and junior medical clinicians from NSW Health conducted the second phase. Of the eleven tools that were assessed against the evaluation instrument only 4 tools completely met the DDS definition that was adopted for this evaluation and were able to produce a differential diagnosis. From the initial phase of the evaluation 4 DDS tools scored 70% or more (maximum score 96%) for the content category, 8 tools scored 65% or more (maximum 100%) for the quality control category, 5 tools scored 65% or more (maximum 94%) for the search category, and 4 tools score 70% or more (maximum 81%) for the clinical results category. The second phase of the evaluation was focused on assessing diagnostic accuracy for the top 3 tools identified in the initial phase. Best Practice ranked highest overall against the 6 clinical case scenarios used. Overall the differentiating factor between the top 3 DDS tools was determined by diagnostic accuracy ranking, ease of use and the confidence and credibility of the clinical information. The evaluation methodology used here to assess the quality and comprehensiveness of clinical DDS tools was effective in identifying the most appropriate tool for the clinical setting. The use of clinical case scenarios is fundamental in determining the diagnostic accuracy and usability of the tools.

  3. Development of a smartphone-based pulse oximeter with adaptive SNR/power balancing.

    PubMed

    Phelps, Tom; Haowei Jiang; Hall, Drew A

    2017-07-01

    Millions worldwide suffer from diseases that exhibit early warnings signs that can be detected by standard clinical-grade diagnostic tools. Unfortunately, such tools are often prohibitively expensive to the developing world leading to inadequate healthcare and high mortality rates. To address this problem, a smartphone-based pulse oximeter is presented that interfaces with the phone through the audio jack, enabling point-of-care measurements of heart rate (HR) and oxygen saturation (SpO 2 ). The device is designed to utilize existing phone resources (e.g., the processor, battery, and memory) resulting in a more portable and inexpensive diagnostic tool than standalone equivalents. By adaptively tuning the LED driving signal, the device is less dependent on phone-specific audio jack properties than prior audio jack-based work making it universally compatible with all smartphones. We demonstrate that the pulse oximeter can adaptively optimize the signal-to-noise ratio (SNR) within the power constraints of a mobile phone (<; 10mW) while maintaining high accuracy (HR error <; 3.4% and SpO 2 error <; 3.7%) against a clinical grade instrument.

  4. The Berlin Inventory of Gambling behavior - Screening (BIG-S): Validation using a clinical sample.

    PubMed

    Wejbera, Martin; Müller, Kai W; Becker, Jan; Beutel, Manfred E

    2017-05-18

    Published diagnostic questionnaires for gambling disorder in German are either based on DSM-III criteria or focus on aspects other than life time prevalence. This study was designed to assess the usability of the DSM-IV criteria based Berlin Inventory of Gambling Behavior Screening tool in a clinical sample and adapt it to DSM-5 criteria. In a sample of 432 patients presenting for behavioral addiction assessment at the University Medical Center Mainz, we checked the screening tool's results against clinical diagnosis and compared a subsample of n=300 clinically diagnosed gambling disorder patients with a comparison group of n=132. The BIG-S produced a sensitivity of 99.7% and a specificity of 96.2%. The instrument's unidimensionality and the diagnostic improvements of DSM-5 criteria were verified by exploratory and confirmatory factor analysis as well as receiver operating characteristic analysis. The BIG-S is a reliable and valid screening tool for gambling disorder and demonstrated its concise and comprehensible operationalization of current DSM-5 criteria in a clinical setting.

  5. MicroRNAs (miRNAs) as biomarker(s) for prognosis and diagnosis of gastrointestinal (GI) cancers.

    PubMed

    Macha, Muzafar A; Seshacharyulu, Parthasarathy; Krishn, Shiv Ram; Pai, Priya; Rachagani, Satyanarayana; Jain, Maneesh; Batra, Surinder K

    2014-01-01

    Gastrointestinal (GI) cancers remain one of the most common malignancies and are the second common cause of cancer deaths worldwide. The limited effectiveness of therapy for patients with advanced stage and recurrent disease is a reflection of an incomplete understanding of the molecular basis of GI carcinogenesis. Major advancements have improved our understanding of pathology and pathogenesis of GI cancers, but high mortality rates, unfavorable prognosis and lack of clinical predictive biomarkers provide an impetus to investigate new sensitive and specific diagnostic and prognostic markers for GI cancers. MicroRNAs (miRNAs) are short (19-24 nucleotides) noncoding RNA molecules that regulate gene expression at the posttranscriptional level thus playing an important role in modulating various biological processes including, but not limited to developmental processes, proliferation, apoptosis, metabolism, differentiation, epithelial-mechenchymal transition and are involved in the initiation and progression of various human cancers. Unique miRNA expression profiles have been observed in various cancer types at different stages, suggesting their potential as diagnostic and prognostic biomarkers. Due to their tumor-specific and tissue-specific expression profiles, stability, robust clinical assays for detection in serum as well as in formalin-fixed tissue samples, miRNAs have emerged as attractive candidates for diagnostic and prognostic applications. This review summarizes recent research supporting the utility of miRNAs as novel diagnostic and prognostic tools for GI cancers.

  6. MicroRNAs (miRNAs) as Biomarker(s) for Prognosis and Diagnosis of Gastrointestinal (GI) Cancers

    PubMed Central

    Macha, Muzafar A.; Seshacharyulu, Parthasarathy; Krishn, Shiv Ram; Pai, Priya; Rachagani, Satyanarayana; Jain, Maneesh; Batra, Surinder K.

    2014-01-01

    Gastrointestinal (GI) cancers remain one of the most common malignancies and are the second common cause of cancer deaths worldwide. The limited effectiveness of therapy for patients with advanced stage and recurrent disease is a reflection of an incomplete understanding of the molecular basis of GI carcinogenesis. Major advancements have improved our understanding of pathology and pathogenesis of GI cancers, but high mortality rates, unfavorable prognosis and lack of clinical predictive biomarkers provide an impetus to investigate new sensitive and specific diagnostic and prognostic markers for GI cancers. MicroRNAs (miRNAs) are short (19–24 nucleotides) noncoding RNA molecules that regulate gene expression at the posttranscriptional level thus playing an important role in modulating various biological processes including, but not limited, to developmental processes, proliferation, apoptosis, metabolism, differentiation, epithelial-mechenchymal transition and are involved in the initiation and progression of various human cancers. Unique miRNA expression profiles have been observed in various cancer types at different stages, suggesting their potential as diagnostic and prognostic biomarkers. Due to their tumor-specific and tissue-specific expression profiles, stability, robust clinical assays for detection in serum as well as in formalin-fixed tissue samples, miRNAs have emerged as attractive candidates for diagnostic and prognostic applications. This review summarizes recent research supporting the utility of miRNAs as novel diagnostic and prognostic tools for GI cancers. PMID:24479799

  7. A Novel Malaria Pf/Pv Ab Rapid Diagnostic Test Using a Differential Diagnostic Marker Identified by Network Biology.

    PubMed

    Cho, Sung Jin; Lee, Jihoo; Lee, Hyun Jae; Jo, Hyun-Young; Sinniah, Mangalam; Kim, Hak-Yong; Chong, Chom-Kyu; Song, Hyun-Ok

    2016-01-01

    Rapid diagnostic tests (RDTs) can detect anti-malaria antibodies in human blood. As they can detect parasite infection at the low parasite density, they are useful in endemic areas where light infection and/or re-infection of parasites are common. Thus, malaria antibody tests can be used for screening bloods in blood banks to prevent transfusion-transmitted malaria (TTM), an emerging problem in malaria endemic areas. However, only a few malaria antibody tests are available in the microwell-based assay format and these are not suitable for field application. A novel malaria antibody (Ab)-based RDT using a differential diagnostic marker for falciparum and vivax malaria was developed as a suitable high-throughput assay that is sensitive and practical for blood screening. The marker, merozoite surface protein 1 (MSP1) was discovered by generation of a Plasmodium-specific network and the hierarchical organization of modularity in the network. Clinical evaluation revealed that the novel Malaria Pf/Pv Ab RDT shows improved sensitivity (98%) and specificity (99.7%) compared with the performance of a commercial kit, SD BioLine Malaria P.f/P.v (95.1% sensitivity and 99.1% specificity). The novel Malaria Pf/Pv Ab RDT has potential for use as a cost-effective blood-screening tool for malaria and in turn, reduces TTM risk in endemic areas.

  8. Diagnostic accuracy of the 14C-urea breath test in Helicobacter pylori infections: a meta-analysis.

    PubMed

    Zhou, Qiaohui; Li, Ling; Ai, Yaowei; Pan, Zhihong; Guo, Mingwen; Han, Jingbo

    2017-01-01

    To summarize and appraise the available literature regarding the use of the 14 C-urea breath test in the diagnosis of Helicobacter pylori infections in adult patients with dyspepsia and to calculate pooled diagnostic accuracy measures. We systematically searched the PubMed, EMBASE, Cochrane Library, Chinese Journals Full-text (CNKI) and CBMDisc databases to identify published data regarding the sensitivity, specificity, and other measures of diagnostic accuracy of the 14 C-urea breath test in the diagnosis of Helicobacter pylori infections in adult patients with dyspeptic symptoms. Risk of bias was assessed using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies)-2 tool. Statistical analyses were performed using Meta-Disc 1.4 software and STATA. Eighteen studies met the inclusion criteria. Pooled results indicated that the  14 C-urea breath test showed a diagnostic sensitivity of 0.96 (95% CI 0.95 to 0.96) and specificity of 0.93 (95% CI 0.91 to 0.94). The positive like ratio (PLR) was 12.27 (95% CI 8.17 to 18.44), the negative like ratio (NLR) was 0.05 (95% CI 0.04 to 0.07), and the area under the curve was 0.985. The DOR was 294.95 (95% CI 178.37 to 487.70). The 14 C-urea breath test showed sufficient sensitivity and specificity for diagnosing Helicobacter pylori infection, but unexplained heterogeneity after meta-regression and several subgroup analyses remained. The UBT has high accuracy for diagnosing H. pylori infections in adult patients with dyspepsia. However, the reliability of these diagnostic meta-analytic estimates is limited by significant heterogeneity due to unknown factors.

  9. Diagnostic accuracy, risk assessment, and cost-effectiveness of component-resolved diagnostics for food allergy: A systematic review.

    PubMed

    Flores Kim, J; McCleary, N; Nwaru, B I; Stoddart, A; Sheikh, A

    2018-01-10

    Component-resolved diagnostics (CRD) are promising tools for diagnosing food allergy, offering the potential to determine specific phenotypes and to develop patient-tailored risk profiles. Nevertheless, the diagnostic accuracy of these tests varies across studies; thus, their clinical utility remains unclear. Therefore, we synthesized the evidence from studies investigating the diagnostic accuracy, risk assessment ability, and cost-effectiveness of CRD for food allergy. We systematically searched 10 electronic databases and four clinical trial registries for studies published from January 2000 to February 2017. The quality of included studies was assessed using QUADAS-2. Due to heterogeneity, we narratively synthesized the evidence. Eleven studies met inclusion criteria, altogether recruiting 1098 participants. The food allergies investigated were cow's milk, hen's egg, peanut, hazelnut, and shrimp. The components with the highest diagnostic accuracy for each allergen, along with their sensitivity-specificity pairs, were as follows: Bos d 4 for cow's milk (62.0% and 87.5%), Gal d 1 for hen's egg (84.2% and 89.8% for heated egg, and 60.6% and 97.1% for raw egg), Ara h 6 for peanut (94.9% and 95.1%), Cor a 14 for hazelnut (100% and 93.8%), and Lit v 1 for shrimp (82.8% and 56.3%) allergy. Selected components of cow's milk, hen's egg, peanut, hazelnut, and shrimp allergen showed high specificity, but lower sensitivity. However, few studies exist for each component, and studies vary widely regarding the cutoff values used, making it challenging to synthesize findings across studies. Further research is needed to determine clinically appropriate cutoff values, risk assessment abilities, and cost-effectiveness of CRD approaches. © 2018 The Authors. Allergy Published by John Wiley & Sons Ltd.

  10. Prehospital lung ultrasound for the diagnosis of cardiogenic pulmonary oedema: a pilot study.

    PubMed

    Laursen, Christian B; Hänselmann, Anja; Posth, Stefan; Mikkelsen, Søren; Videbæk, Lars; Berg, Henrik

    2016-08-02

    An improved prehospital diagnostic accuracy of cardiogenic pulmonary oedema could potentially improve initial treatment, triage, and outcome. A pilot study was conducted to assess the feasibility, time-use, and diagnostic accuracy of prehospital lung ultrasound (PLUS) for the diagnosis of cardiogenic pulmonary oedema. A prospective observational study was conducted in a prehospital setting. Patients were included if the physician based prehospital mobile emergency care unit was activated and one or more of the following two were present: respiratory rate >30/min., oxygen saturation <90 %. Exclusion criteria were: age <18 years, permanent mental disability or PLUS causing a delay in life-saving treatment or transportation. Following clinical assessment PLUS was performed and presence or absence of interstitial syndrome was registered. Audit by three physicians using predefined diagnostic criteria for cardiogenic pulmonary oedema was used as gold standard. A total of 40 patients were included in the study. Feasibility of PLUS was 100 % and median time used was 3 min. The gold standard diagnosed 18 (45.0 %) patients with cardiogenic pulmonary oedema. The diagnostic accuracy of PLUS for the diagnosis of cardiogenic pulmonary oedema was: sensitivity 94.4 % (95 % confidence interval (CI) 72.7-99.9 %), specificity 77.3 % (95 % CI 54.6-92.2 %), positive predictive value 77.3 % (95 % CI 54.6-92.2 %), negative predictive value 94.4 % (95 % CI 72.7-99.9 %). The sensitivity of PLUS is high, making it a potential tool for ruling-out cardiogenic pulmonary. The observed specificity was lower than what has been described in previous studies. Performed, as part of a physician based prehospital emergency service, PLUS seems fast and highly feasible in patients with respiratory failure. Due to its diagnostic accuracy, PLUS may have potential as a prehospital tool, especially to rule out cardiogenic pulmonary oedema.

  11. Diagnostic accuracy of fundal height and handheld ultrasound-measured abdominal circumference to screen for fetal growth abnormalities

    PubMed Central

    Haragan, Adriane F.; Hulsey, Thomas C.; Hawk, Angela F.; Newman, Roger B.; Chang, Eugene Y.

    2015-01-01

    OBJECTIVE We sought to compare fundal height and handheld ultrasound–measured fetal abdominal circumference (HHAC) for the prediction of fetal growth restriction (FGR) or large for gestational age. STUDY DESIGN This was a diagnostic accuracy study in nonanomalous singleton pregnancies between 24 and 40 weeks’ gestation. Patients underwent HHAC and fundal height measurement prior to formal growth ultrasound. FGR was defined as estimated fetal weight less than 10%, whereas large for gestational age was defined as estimated fetal weight greater than 90%. Sensitivity and specificity were calculated and compared using methods described elsewhere. RESULTS There were 251 patients included in this study. HHAC had superior sensitivity and specificity for the detection of FGR (sensitivity, 100% vs 42.86%) and (specificity, 92.62% vs 85.24%). HHAC had higher specificity but lower sensitivity when screening for LGA (specificity, 85.66% vs 66.39%) and (sensitivity, 57.14% vs 71.43%). CONCLUSION HHAC could prove to be a valuable screening tool in the detection of FGR. Further studies are needed in a larger population. PMID:25818672

  12. Active Surveillance of Prostate Cancer: Use, Outcomes, Imaging, and Diagnostic Tools

    PubMed Central

    Tosoian, Jeffrey J; Loeb, Stacy; Epstein, Jonathan I; Turkbey, Baris; Choyke, Peter; Schaeffer, Edward M

    2016-01-01

    Active surveillance (AS) has emerged as a standard management option for men with very low-risk and low-risk prostate cancer, and contemporary data indicate that use of AS is increasing in the United States and abroad. In the favorable-risk population, reports from multiple prospective cohorts indicate a less than 1% likelihood of metastatic disease and prostate cancer-specific mortality over intermediate-term follow-up (median 5 to 6 years). Higher-risk men participating in AS appear to be at increased risk of adverse outcomes, but these populations have not been adequately studied to this point. Although monitoring on AS largely relies on serial prostate biopsy, a procedure associated with significant morbidity, there is a need for improved diagnostic tools for patient selection and monitoring. Revisions from the 2014 International Society of Urologic Pathology consensus conference have yielded a more intuitive reporting system and detailed reporting of low-intermediate grade tumors, which should facilitate the practice of AS. Meanwhile, emerging modalities such as multiparametric magnetic resonance imaging and tissue-based molecular testing have shown prognostic value in some populations. At this time, however, these instruments have not been sufficiently studied to consider their routine, standardized use in the AS setting. Future studies should seek to identify those platforms most informative in the AS population and propose a strategy by which promising diagnostic tools can be safely and efficiently incorporated into clinical practice. PMID:27249729

  13. MO-AB-210-00: Diagnostic Ultrasound Imaging Quality Control and High Intensity Focused Ultrasound Therapy Hands-On Workshop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrationsmore » with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.« less

  14. Auditory brainstem response as a diagnostic tool for patients suffering from schizophrenia, attention deficit hyperactivity disorder, and bipolar disorder: protocol.

    PubMed

    Wahlström, Viktor; Åhlander, Fredrik; Wynn, Rolf

    2015-02-12

    Psychiatric disorders, such as schizophrenia, attention deficit hyperactivity disorder (ADHD), and bipolar disorder, may sometimes be difficult to diagnose. There is a great need for a valid and reliable diagnostic tool to aid clinicians in arriving at the diagnoses in a timely and accurate manner. Prior studies have suggested that patients suffering from schizophrenia and ADHD may process certain sound stimuli in the brainstem in an unusual manner. When these patient groups have been examined with the electrophysiological method of brainstem audiometry, some studies have found illness-specific aberrations. Such aberrations may also exist for patients suffering from bipolar disorder. In this study, we will examine whether the method of brainstem audiometry can be used as a diagnostic tool for patients suffering from schizophrenia, ADHD, and bipolar disorder. The method includes three steps: (1) auditory stimulation with specific sound stimuli, (2) simultaneous measurement of brainstem activity, and (3) automated interpretation of the resulting brain stem audiograms with data-based signal analysis. We will compare three groups of 12 individuals with confirmed diagnoses of schizophrenia, ADHD, or bipolar disorder with 12 healthy subjects under blinded conditions for a total of 48 participants. The extent to which the method can be used to reach the correct diagnosis will be investigated. The project is now in a recruiting phase. When all patients and controls have been recruited and the measurements have been performed, the data will be analyzed according to a previously arranged algorithm. We expect the recruiting phase and measurements to be completed in early 2015, the analyses to be performed in mid-2015, and the results of the study to be published in early 2016. If the results support previous findings, this will lend strength to the idea that brainstem audiometry can offer objective diagnostic support for patients suffering from schizophrenia, ADHD, and bipolar disorder. A positive result from the study could imply that brainstem audiometry could become an important supportive tool for clinicians in their efforts to diagnose patients with these disorders in a timely and accurate manner. ClinicalTrials.gov NCT01629355; https://clinicaltrials.gov/ct2/show/NCT01629355 (Archived by WebCite at http://www.webcitation.org/6VBfTwx5H).

  15. Residual gas analyzer mass spectrometry for human breath analysis: a new tool for the non-invasive diagnosis of Helicobacter pylori infection.

    PubMed

    Maity, Abhijit; Banik, Gourab D; Ghosh, Chiranjit; Som, Suman; Chaudhuri, Sujit; Daschakraborty, Sunil B; Ghosh, Shibendu; Ghosh, Barnali; Raychaudhuri, Arup K; Pradhan, Manik

    2014-03-01

    A residual gas analyzer (RGA) coupled with a high vacuum chamber is described for the non-invasive diagnosis of the Helicobacter pylori (H. pylori) infection through ¹³C-urea breath analysis. The present RGA-based mass spectrometry (MS) method is capable of measuring high-precision ¹³CO₂ isotope enrichments in exhaled breath samples from individuals harboring the H. pylori infection. The system exhibited 100% diagnostic sensitivity, and 93% specificity alongside positive and negative predictive values of 95% and 100%, respectively, compared with invasive endoscopy-based biopsy tests. A statistically sound diagnostic cut-off value for the presence of H. pylori was determined to be 3.0‰ using a receiver operating characteristic curve analysis. The diagnostic accuracy and validity of the results are also supported by optical off-axis integrated cavity output spectroscopy measurements. The δ¹³(DOB)C‰ values of both methods correlated well (R² = 0.9973 at 30 min). The RGA-based instrumental setup described here is simple, robust, easy-to-use and more portable and cost-effective compared to all other currently available detection methods, thus making it a new point-of-care medical diagnostic tool for the purpose of large-scale screening of the H. pylori infection in real time. The RGA-MS technique should have broad applicability for ¹³C-breath tests in a wide range of biomedical research and clinical diagnostics for many other diseases and metabolic disorders.

  16. Streptococcus A in paediatric accident and emergency: are rapid streptococcal tests and clinical examination of any help?

    PubMed

    Van Limbergen, J; Kalima, P; Taheri, S; Beattie, T F

    2006-01-01

    Rapid streptococcal tests (RSTs) for streptococcal pharyngitis have made diagnosis at once simpler and more complicated. The American Academy of Pediatrics recommends that all RSTs be confirmed by a follow up throat culture unless local validation has proved the RST to be equally sensitive. To evaluate (a) RST as a single diagnostic tool, compared with RST with or without throat culture; (b) clinical diagnosis and the relative contribution of different symptoms. The study included 213 patients with clinical signs of pharyngitis. Throat swabs were analysed using Quickvue+ Strep A Test; negative RSTs were backed up by throat culture. Thirteen clinical features commonly associated with strep throat were analysed using backward stepwise logistic regression. Positive results (RST or throat culture) were obtained in 33 patients; RST correctly identified 21. Eleven samples were false negative on RST. At a strep throat prevalence of 15.9%, sensitivity of RST was 65.6% (95% CI 46.8% to 81.4%) and specificity 99.4% (96.7% to 99.9%). Sensitivity of clinical diagnosis alone was 57% (34% to 78%) and specificity 71% (61% to 80%). Clinically, only history of sore throat, rash, and pyrexia contributed to the diagnosis of strep throat (p<0.05). The high specificity of RST facilitates early diagnosis of strep throat. However, the low sensitivity of RST does not support its use as a single diagnostic tool. The sensitivity in the present study is markedly different from that reported by the manufacturer. Clinical examination is of limited value in the diagnosis of strep throat. It is important to audit the performance of new diagnostic tests, previously validated in different settings.

  17. Streptococcus A in paediatric accident and emergency: are rapid streptococcal tests and clinical examination of any help?

    PubMed Central

    Van Limbergen, J; Kalima, P; Taheri, S; Beattie, T F

    2006-01-01

    Background Rapid streptococcal tests (RSTs) for streptococcal pharyngitis have made diagnosis at once simpler and more complicated. The American Academy of Pediatrics recommends that all RSTs be confirmed by a follow up throat culture unless local validation has proved the RST to be equally sensitive. Aims To evaluate (a) RST as a single diagnostic tool, compared with RST with or without throat culture; (b) clinical diagnosis and the relative contribution of different symptoms. Methods The study included 213 patients with clinical signs of pharyngitis. Throat swabs were analysed using Quickvue+ Strep A Test; negative RSTs were backed up by throat culture. Thirteen clinical features commonly associated with strep throat were analysed using backward stepwise logistic regression. Results Positive results (RST or throat culture) were obtained in 33 patients; RST correctly identified 21. Eleven samples were false negative on RST. At a strep throat prevalence of 15.9%, sensitivity of RST was 65.6% (95% CI 46.8% to 81.4%) and specificity 99.4% (96.7% to 99.9%). Sensitivity of clinical diagnosis alone was 57% (34% to 78%) and specificity 71% (61% to 80%). Clinically, only history of sore throat, rash, and pyrexia contributed to the diagnosis of strep throat (p<0.05). Conclusion The high specificity of RST facilitates early diagnosis of strep throat. However, the low sensitivity of RST does not support its use as a single diagnostic tool. The sensitivity in the present study is markedly different from that reported by the manufacturer. Clinical examination is of limited value in the diagnosis of strep throat. It is important to audit the performance of new diagnostic tests, previously validated in different settings. PMID:16373800

  18. Evaluation of Targeted Next-Generation Sequencing for Detection of Bovine Pathogens in Clinical Samples.

    PubMed

    Anis, Eman; Hawkins, Ian K; Ilha, Marcia R S; Woldemeskel, Moges W; Saliki, Jeremiah T; Wilkes, Rebecca P

    2018-07-01

    The laboratory diagnosis of infectious diseases, especially those caused by mixed infections, is challenging. Routinely, it requires submission of multiple samples to separate laboratories. Advances in next-generation sequencing (NGS) have provided the opportunity for development of a comprehensive method to identify infectious agents. This study describes the use of target-specific primers for PCR-mediated amplification with the NGS technology in which pathogen genomic regions of interest are enriched and selectively sequenced from clinical samples. In the study, 198 primers were designed to target 43 common bovine and small-ruminant bacterial, fungal, viral, and parasitic pathogens, and a bioinformatics tool was specifically constructed for the detection of targeted pathogens. The primers were confirmed to detect the intended pathogens by testing reference strains and isolates. The method was then validated using 60 clinical samples (including tissues, feces, and milk) that were also tested with other routine diagnostic techniques. The detection limits of the targeted NGS method were evaluated using 10 representative pathogens that were also tested by quantitative PCR (qPCR), and the NGS method was able to detect the organisms from samples with qPCR threshold cycle ( C T ) values in the 30s. The method was successful for the detection of multiple pathogens in the clinical samples, including some additional pathogens missed by the routine techniques because the specific tests needed for the particular organisms were not performed. The results demonstrate the feasibility of the approach and indicate that it is possible to incorporate NGS as a diagnostic tool in a cost-effective manner into a veterinary diagnostic laboratory. Copyright © 2018 Anis et al.

  19. The vasovagal tonus index as a prognostic indicator in dogs with dilated cardiomyopathy.

    PubMed

    Pereira, Y Martinez; Woolley, R; Culshaw, G; French, A; Martin, M

    2008-11-01

    To investigate the prognostic and diagnostic value of heart rate variability (HRV) using the vasovagal tonus index (VVTI) in dogs suffering from idiopathic dilated cardiomyopathy (DCM). Electrocardiographic (ECG) recordings of 369 patients presented to a referral centre between 1993 and 2006 were reviewed. VVTI values were calculated from 132 dogs. Lower VVTI values were found in patients in International Small Animal Cardiac Health Council (ISACHC) heart failure (HF) class 2 and 3 compared with class 1. VVTI was found to be positively correlated with survival time (ST) in class 2 and 3 patients. When a cut-off value of 7.59 for VVTI was used, the test could differentiate patients in ISACHC HF class 1 versus 2 and 3 with a sensitivity of 89 per cent and a specificity of 62.5 per cent. The ST for patients with VVTI values less than 7.59 was significantly lower. The VVTI is a useful index, obtained from a standard ECG recording that estimates HRV in dogs and does not require any specific equipment for its calculation. It can be useful as a diagnostic tool to assess the severity of HF and is a useful prognostic tool in dogs with DCM.

  20. Diagnostic Tools for Performance Evaluation of Innovative In-Situ Remediation Technologies at Chlorinated Solvent-Contaminated Sites

    DTIC Science & Technology

    2011-07-01

    to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT...these innovative methods with conventional diagnostic tools that are currently used for assessing bioremediation performance. 132 Rula Deeb (510) 596...conventional diagnostic tools that are currently used for assessing bioremediation performance. DEMONSTRATION RESULTS 3-D multi-level systems

  1. Molecular property diagnostic suite (MPDS): Development of disease-specific open source web portals for drug discovery.

    PubMed

    Nagamani, S; Gaur, A S; Tanneeru, K; Muneeswaran, G; Madugula, S S; Consortium, Mpds; Druzhilovskiy, D; Poroikov, V V; Sastry, G N

    2017-11-01

    Molecular property diagnostic suite (MPDS) is a Galaxy-based open source drug discovery and development platform. MPDS web portals are designed for several diseases, such as tuberculosis, diabetes mellitus, and other metabolic disorders, specifically aimed to evaluate and estimate the drug-likeness of a given molecule. MPDS consists of three modules, namely data libraries, data processing, and data analysis tools which are configured and interconnected to assist drug discovery for specific diseases. The data library module encompasses vast information on chemical space, wherein the MPDS compound library comprises 110.31 million unique molecules generated from public domain databases. Every molecule is assigned with a unique ID and card, which provides complete information for the molecule. Some of the modules in the MPDS are specific to the diseases, while others are non-specific. Importantly, a suitably altered protocol can be effectively generated for another disease-specific MPDS web portal by modifying some of the modules. Thus, the MPDS suite of web portals shows great promise to emerge as disease-specific portals of great value, integrating chemoinformatics, bioinformatics, molecular modelling, and structure- and analogue-based drug discovery approaches.

  2. Recent advances in salivary cancer diagnostics enabled by biosensors and bioelectronics.

    PubMed

    Mishra, Saswat; Saadat, Darius; Kwon, Ohjin; Lee, Yongkuk; Choi, Woon-Seop; Kim, Jong-Hoon; Yeo, Woon-Hong

    2016-07-15

    There is a high demand for a non-invasive, rapid, and highly accurate tool for disease diagnostics. Recently, saliva based diagnostics for the detection of specific biomarkers has drawn significant attention since the sample extraction is simple, cost-effective, and precise. Compared to blood, saliva contains a similar variety of DNA, RNA, proteins, metabolites, and microbiota that can be compiled into a multiplex of cancer detection markers. The salivary diagnostic method holds great potential for early-stage cancer diagnostics without any complicated and expensive procedures. Here, we review various cancer biomarkers in saliva and compare the biomarkers efficacy with traditional diagnostics and state-of-the-art bioelectronics. We summarize biomarkers in four major groups: genomics, transcriptomics, proteomics, and metabolomics/microbiota. Representative bioelectronic systems for each group are summarized based on various stages of a cancer. Systematic study of oxidative stress establishes the relationship between macromolecules and cancer biomarkers in saliva. We also introduce the most recent examples of salivary diagnostic electronics based on nanotechnologies that can offer rapid, yet highly accurate detection of biomarkers. A concluding section highlights areas of opportunity in the further development and applications of these technologies. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Salivary Biomarkers in Cancer Detection

    PubMed Central

    Wang, Xiaoqian; Kaczor-Urbanowicz, Karolina Elżbieta; Wong, David T.W.

    2017-01-01

    Cancer is the second most common cause of death in the United States. Its symptoms are often not specific and absent, until the tumors have already metastasized. Therefore, there is an urgent demand for developing rapid, highly accurate and non-invasive tools for cancer screening, early detection, diagnostics, staging and prognostics. Saliva as a multi-constituent oral fluid, comprises secretions from the major and minor salivary glands, extensively supplied by blood. Molecules such as DNAs, RNAs, proteins, metabolites, and microbiota, present in blood, could be also found in saliva. Recently, salivary diagnostics has drawn significant attention for the detection of specific biomarkers, since the sample collection and processing are simple, cost-effective, precise and do not cause patient discomfort. Here, we review recent salivary candidate biomarkers for systemic cancers by dividing them according to their origin into: genomic, transcriptomic, proteomic, metabolomic and microbial types. PMID:27943101

  4. New insights in IBS-like disorders: Pandora's box has been opened; a review.

    PubMed

    Borghini, Raffaele; Donato, Giuseppe; Alvaro, Domenico; Picarelli, Antonio

    2017-01-01

    The most complained gastrointestinal symptoms are chronic diarrhea, bloating and abdominal pain. Once malignancies and inflammatory bowel diseases are excluded, irritable bowel syndrome (IBS) and the so called "IBS-like disorders" should be taken into account. The relationship between IBS as defined by Rome IV criteria and these clinical conditions is sometimes obscure, since many IBS patients identify food as a possible trigger for their symptoms. Here, we discuss IBS and the most common IBS-like disorders (celiac disease, non-celiac gluten sensitivity, fermentable oligosaccharides, disaccharides, monosaccharides and polyols (FODMAPs), lactose intolerance, small intestinal bacterial overgrowth (SIBO), α-amylase/trypsin inhibitor (ATIs), nickel allergic contact mucositis), focusing on epidemiologic, clinical, diagnostic and therapeutic aspects. Given the lack of specificity of symptoms, clinical investigation will be facilitated by awareness of these disorders as well as new specific diagnostic tools.

  5. Space Laboratory on a Table Top: A Next Generative ECLSS design and diagnostic tool

    NASA Technical Reports Server (NTRS)

    Ramachandran, N.

    2005-01-01

    This paper describes the development plan for a comprehensive research and diagnostic tool for aspects of advanced life support systems in space-based laboratories. Specifically it aims to build a high fidelity tabletop model that can be used for the purpose of risk mitigation, failure mode analysis, contamination tracking, and testing reliability. We envision a comprehensive approach involving experimental work coupled with numerical simulation to develop this diagnostic tool. It envisions a 10% scale transparent model of a space platform such as the International Space Station that operates with water or a specific matched index of refraction liquid as the working fluid. This allows the scaling of a 10 ft x 10 ft x 10 ft room with air flow to 1 ft x 1 ft x 1 ft tabletop model with water/liquid flow. Dynamic similitude for this length scale dictates model velocities to be 67% of full-scale and thereby the time scale of the model to represent 15% of the full- scale system; meaning identical processes in the model are completed in 15% of the full- scale-time. The use of an index matching fluid (fluid that matches the refractive index of cast acrylic, the model material) allows making the entire model (with complex internal geometry) transparent and hence conducive to non-intrusive optical diagnostics. So using such a system one can test environment control parameters such as core flows (axial flows), cross flows (from registers and diffusers), potential problem areas such as flow short circuits, inadequate oxygen content, build up of other gases beyond desirable levels, test mixing processes within the system at local nodes or compartments and assess the overall system performance. The system allows quantitative measurements of contaminants introduced in the system and allows testing and optimizing the tracking process and removal of contaminants. The envisaged system will be modular and hence flexible for quick configuration change and subsequent testing. The data and inferences from the tests will allow for improvements in the development and design of next generation life support systems and configurations. Preliminary experimental and modeling work in this area will be presented. This involves testing of a single inlet-exit model with detailed 3-D flow visualization and quantitative diagnostics and computational modeling of the system.

  6. Optimal Combination of Non-Invasive Tools for the Early Detection of Potentially Life-Threatening Emergencies in Gynecology

    PubMed Central

    Varas, Catalina; Ravit, Marion; Mimoun, Camille; Panel, Pierre; Huchon, Cyrille; Fauconnier, Arnaud

    2016-01-01

    Objectives Potentially life-threatening gynecological emergencies (G-PLEs) are acute pelvic conditions that may spontaneously evolve into a life-threatening situation, or those for which there is a risk of sequelae or death in the absence of prompt diagnosis and treatment. The objective of this study was to identify the best combination of non-invasive diagnostic tools to ensure an accurate diagnosis and timely response when faced with G-PLEs for patients arriving with acute pelvic pain at the Gynecological Emergency Department (ED). Methods The data on non-invasive diagnostic tools were sourced from the records of patients presenting at the ED of two hospitals in the Parisian suburbs (France) with acute pelvic pain between September 2006 and April 2008. The medical history of the patients was obtained through a standardized questionnaire completed for a prospective observational study, and missing information was completed with data sourced from the medical forms. Diagnostic tool categories were predefined as a collection of signs or symptoms. We analyzed the association of each sign/symptom with G-PLEs using Pearson’s Chi-Square or Fischer’s exact tests. Symptoms and signs associated with G-PLEs (p-value < 0.20) were subjected to logistic regression to evaluate the diagnostic value of each of the predefined diagnostic tools and in various combinations. Results The data of 365 patients with acute pelvic pain were analyzed, of whom 103 were confirmed to have a PLE. We analyzed five diagnostic tools by logistic regression: Triage Process, History-Taking, Physical Examination, Ultrasonography, and Biological Exams. The combination of History-Taking and Ultrasonography had a C-index of 0.83, the highest for a model combining two tools. Conclusions The use of a standardized self-assessment questionnaire for history-taking and focal ultrasound examination were found to be the most successful tool combination for the diagnosis of gynecological emergencies in a Gynecological ED. Additional tools, such as physical examination, do not add substantial diagnostic value. PMID:27583697

  7. Applied Genomics: Data Mining Reveals Species-Specific Malaria Diagnostic Targets More Sensitive than 18S rRNA▿†‡

    PubMed Central

    Demas, Allison; Oberstaller, Jenna; DeBarry, Jeremy; Lucchi, Naomi W.; Srinivasamoorthy, Ganesh; Sumari, Deborah; Kabanywanyi, Abdunoor M.; Villegas, Leopoldo; Escalante, Ananias A.; Kachur, S. Patrick; Barnwell, John W.; Peterson, David S.; Udhayakumar, Venkatachalam; Kissinger, Jessica C.

    2011-01-01

    Accurate and rapid diagnosis of malaria infections is crucial for implementing species-appropriate treatment and saving lives. Molecular diagnostic tools are the most accurate and sensitive method of detecting Plasmodium, differentiating between Plasmodium species, and detecting subclinical infections. Despite available whole-genome sequence data for Plasmodium falciparum and P. vivax, the majority of PCR-based methods still rely on the 18S rRNA gene targets. Historically, this gene has served as the best target for diagnostic assays. However, it is limited in its ability to detect mixed infections in multiplex assay platforms without the use of nested PCR. New diagnostic targets are needed. Ideal targets will be species specific, highly sensitive, and amenable to both single-step and multiplex PCRs. We have mined the genomes of P. falciparum and P. vivax to identify species-specific, repetitive sequences that serve as new PCR targets for the detection of malaria. We show that these targets (Pvr47 and Pfr364) exist in 14 to 41 copies and are more sensitive than 18S rRNA when utilized in a single-step PCR. Parasites are routinely detected at levels of 1 to 10 parasites/μl. The reaction can be multiplexed to detect both species in a single reaction. We have examined 7 P. falciparum strains and 91 P. falciparum clinical isolates from Tanzania and 10 P. vivax strains and 96 P. vivax clinical isolates from Venezuela, and we have verified a sensitivity and specificity of ∼100% for both targets compared with a nested 18S rRNA approach. We show that bioinformatics approaches can be successfully applied to identify novel diagnostic targets and improve molecular methods for pathogen detection. These novel targets provide a powerful alternative molecular diagnostic method for the detection of P. falciparum and P. vivax in conventional or multiplex PCR platforms. PMID:21525225

  8. Investigating the Effectiveness of Classroom Diagnostic Tools

    ERIC Educational Resources Information Center

    Schultz, Robert K.

    2012-01-01

    The primary purposes of the study are to investigate what teachers experience while using the Classroom Diagnostic Tools (CDT) and to relate those experiences to the rate of growth in students' mathematics achievement. The CDT contains three components: an online computer adaptive diagnostic test, interactive web-based student reports, and…

  9. Unenhanced breast MRI (STIR, T2-weighted TSE, DWIBS): An accurate and alternative strategy for detecting and differentiating breast lesions.

    PubMed

    Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe; Moschetta, Marco

    2015-10-01

    To assess the role of STIR, T2-weighted TSE and DWIBS sequences for detecting and characterizing breast lesions and to compare unenhanced (UE)-MRI results with contrast-enhanced (CE)-MRI and histological findings, having the latter as the reference standard. Two hundred eighty consecutive patients (age range, 27-73 years; mean age±standard deviation (SD), 48.8±9.8years) underwent MR examination with a diagnostic protocol including STIR, T2-weighted TSE, THRIVE and DWIBS sequences. Two radiologists blinded to both dynamic sequences and histological findings evaluated in consensus STIR, T2-weighted TSE and DWIBS sequences and after two weeks CE-MRI images searching for breast lesions. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy for UE-MRI and CE-MRI were calculated. UE-MRI results were also compared with CE- MRI. UE-MRI sequences obtained sensitivity, specificity, diagnostic accuracy, PPV and NPV values of 94%, 79%, 86%, 79% and 94%, respectively. CE-MRI sequences obtained sensitivity, specificity, diagnostic accuracy, PPV and NPV values of 98%, 83%, 90%, 84% and 98%, respectively. No statistically significant difference between UE-MRI and CE-MRI was found. Breast UE-MRI could represent an accurate diagnostic tool and a valid alternative to CE-MRI for evaluating breast lesions. STIR and DWIBS sequences allow to detect breast lesions while T2-weighted TSE sequences and ADC values could be useful for lesion characterization. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. European specialist porphyria laboratories: diagnostic strategies, analytical quality, clinical interpretation, and reporting as assessed by an external quality assurance program.

    PubMed

    Aarsand, Aasne K; Villanger, Jørild H; Støle, Egil; Deybach, Jean-Charles; Marsden, Joanne; To-Figueras, Jordi; Badminton, Mike; Elder, George H; Sandberg, Sverre

    2011-11-01

    The porphyrias are a group of rare metabolic disorders whose diagnosis depends on identification of specific patterns of porphyrin precursor and porphyrin accumulation in urine, blood, and feces. Diagnostic tests for porphyria are performed by specialized laboratories in many countries. Data regarding the analytical and diagnostic performance of these laboratories are scarce. We distributed 5 sets of multispecimen samples from different porphyria patients accompanied by clinical case histories to 18-21 European specialist porphyria laboratories/centers as part of a European Porphyria Network organized external analytical and postanalytical quality assessment (EQA) program. The laboratories stated which analyses they would normally have performed given the case histories and reported results of all porphyria-related analyses available, interpretative comments, and diagnoses. Reported diagnostic strategies initially showed considerable diversity, but the number of laboratories applying adequate diagnostic strategies increased during the study period. We found an average interlaboratory CV of 50% (range 12%-152%) for analytes in absolute concentrations. Result normalization by forming ratios to the upper reference limits did not reduce this variation. Sixty-five percent of reported results were within biological variation-based analytical quality specifications. Clinical interpretation of the obtained analytical results was accurate, and most laboratories established the correct diagnosis in all distributions. Based on a case-based EQA scheme, variations were apparent in analytical and diagnostic performance between European specialist porphyria laboratories. Our findings reinforce the use of EQA schemes as an essential tool to assess both analytical and diagnostic processes and thereby to improve patient care in rare diseases.

  11. Ares I-X Ground Diagnostic Prototype

    NASA Technical Reports Server (NTRS)

    Schwabacher, Mark A.; Martin, Rodney Alexander; Waterman, Robert D.; Oostdyk, Rebecca Lynn; Ossenfort, John P.; Matthews, Bryan

    2010-01-01

    The automation of pre-launch diagnostics for launch vehicles offers three potential benefits: improving safety, reducing cost, and reducing launch delays. The Ares I-X Ground Diagnostic Prototype demonstrated anomaly detection, fault detection, fault isolation, and diagnostics for the Ares I-X first-stage Thrust Vector Control and for the associated ground hydraulics while the vehicle was in the Vehicle Assembly Building at Kennedy Space Center (KSC) and while it was on the launch pad. The prototype combines three existing tools. The first tool, TEAMS (Testability Engineering and Maintenance System), is a model-based tool from Qualtech Systems Inc. for fault isolation and diagnostics. The second tool, SHINE (Spacecraft Health Inference Engine), is a rule-based expert system that was developed at the NASA Jet Propulsion Laboratory. We developed SHINE rules for fault detection and mode identification, and used the outputs of SHINE as inputs to TEAMS. The third tool, IMS (Inductive Monitoring System), is an anomaly detection tool that was developed at NASA Ames Research Center. The three tools were integrated and deployed to KSC, where they were interfaced with live data. This paper describes how the prototype performed during the period of time before the launch, including accuracy and computer resource usage. The paper concludes with some of the lessons that we learned from the experience of developing and deploying the prototype.

  12. The diagnostic value of troponin in critically ill.

    PubMed

    Voga, Gorazd

    2010-01-01

    Troponin T and I are sensitive and specific markers of myocardial necrosis. They are used for the routine diagnosis of acute coronary syndrome. In critically ill patients they are basic diagnostic tool for diagnosis of myocardial necrosis due to myocardial ischemia. Moreover, the increase of troponin I and T is related with adverse outcome in many subgroups of critically ill patients. The new, high sensitivity tests which have been developed recently allow earlier and more accurate diagnosis of acute coronary syndrome. The use of the new tests has not been studied in critically ill patients, but they will probably replace the old tests and will be used on the routine basis.

  13. Non-invasive 13C-glucose breath test using residual gas analyzer-mass spectrometry: a novel tool for screening individuals with pre-diabetes and type 2 diabetes.

    PubMed

    Ghosh, Chiranjit; Maity, Abhijit; Banik, Gourab D; Som, Suman; Chakraborty, Arpita; Selvan, Chitra; Ghosh, Shibendu; Ghosh, Barnali; Chowdhury, Subhankar; Pradhan, Manik

    2014-09-01

    We report, for the first time, the clinical feasibility of a novel residual gas analyzer mass spectrometry (RGA-MS) method for accurate evaluation of the (13)C-glucose breath test ((13)C-GBT) in the diagnosis of pre-diabetes (PD) and type 2 diabetes mellitus (T2D). In T2D or PD, glucose uptake is impaired and results in blunted isotope enriched (13)CO2 production in exhaled breath samples. Using the Receiver operating characteristics (ROC) curve analysis, an optimal diagnostic cut-off point of the (13)CO2/(12)CO2 isotope ratios expressed as the delta-over-baseline (DOB) value, was determined to be δDOB(13)C‰ = 28.81‰ for screening individuals with non-diabetes controls (NDC) and pre-diabetes (PD), corresponding to a sensitivity of 100% and specificity of 94.4%. We also determined another optimal diagnostic cut-off point of δDOB(13)C‰ = 19.88‰ between individuals with PD and T2D, which exhibited 100% sensitivity and 95.5% specificity. Our RGA-MS methodology for the (13)C-GBT also manifested a typical diagnostic positive and negative predictive value of 96% and 100%, respectively. The diagnostic accuracy, precision and validity of the results were also confirmed by high-resolution optical cavity enhanced integrated cavity output spectroscopy (ICOS) measurements. The δDOB(13)C‰ values measured with RGA-MS method, correlated favourably (R(2) = 0.979) with those determined by the laser based ICOS method. Moreover, we observed that the effects of endogenous CO2 production related to basal metabolic rates in individuals were statistically insignificant (p = 0.37 and 0.73) on the diagnostic accuracy. Our findings suggest that the RGA-MS is a valid and sufficiently robust method for the (13)C-GBT which may serve as an alternative non-invasive point-of-care diagnostic tool for routine clinical practices as well as for large-scale diabetes screening purposes in real-time.

  14. Diagnostic Tools for the Systemic Reform of Schools.

    ERIC Educational Resources Information Center

    Amsler, Mary; Kirsch, Kayla

    This paper presents three interrelated diagnostic tools that can be used by school staff as they begin to plan a systemic reform effort. These tools are designed to help educators reflect on their experiences in creating changes in their school and to examine the current barriers to and supports for the change process. The tools help school design…

  15. Measurement properties of screening and diagnostic tools for autism spectrum adults of mean normal intelligence: A systematic review.

    PubMed

    Baghdadli, A; Russet, F; Mottron, L

    2017-07-01

    The autism spectrum (AS) is a multifaceted neurodevelopmental variant associated with lifelong challenges. Despite the relevant importance of identifying AS in adults for epidemiological, public health, and quality of life issues, the measurement properties of the tools currently used to screen and diagnose adults without intellectual disabilities (ID) have not been assessed. This systematic review addresses the accuracy, reliability, and validity of the reported AS screening and diagnostic tools used in adults without ID. Electronic databases and bibliographies were searched, and identified papers evaluated against inclusion criteria. The PRISMA statement was used for reporting the review. We evaluated the quality of the papers using the COSMIN Checklist for psychometric data, and QUADAS-2 for diagnostic data. For the COSMIN assessment, evidence was considered to be strong when several methodologically good articles, or one excellent article, reported consistent evidence for or against a measurement property. For the QUADAS ratings, evidence was considered to be "satisfactory" if at least one study was rated with a low risk of bias and low concern about applicability. We included 38 articles comprising 32 studies, five reviews, and one book chapter and assessed nine tools (three diagnostic and six screening, including eight of their short versions). Among screening tools, only AQ-50, AQ-S, and RAADS-R and RAADS-14 were found to provide satisfactory or intermediate values for their psychometric properties, supported by strong or moderate evidence. Nevertheless, risks of bias and concerns on the applicability of these tools limit the evidence on their diagnostic properties. We found that none of the gold standard diagnostic tools used for children had satisfactory measurement properties. There is limited evidence for the measurement properties of the screening and diagnostic tools used for AS adults with a mean normal range of measured intelligence. This may lessen the validity of conclusions and public health decisions on an important fraction of the adult autistic population. This not only justifies further validation studies of screening and diagnostic tools for autistic adults, but also supports the parallel use of self-reported information and clinical expertise with these instruments during the diagnostic process. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  16. TipMT: Identification of PCR-based taxon-specific markers.

    PubMed

    Rodrigues-Luiz, Gabriela F; Cardoso, Mariana S; Valdivia, Hugo O; Ayala, Edward V; Gontijo, Célia M F; Rodrigues, Thiago de S; Fujiwara, Ricardo T; Lopes, Robson S; Bartholomeu, Daniella C

    2017-02-11

    Molecular genetic markers are one of the most informative and widely used genome features in clinical and environmental diagnostic studies. A polymerase chain reaction (PCR)-based molecular marker is very attractive because it is suitable to high throughput automation and confers high specificity. However, the design of taxon-specific primers may be difficult and time consuming due to the need to identify appropriate genomic regions for annealing primers and to evaluate primer specificity. Here, we report the development of a Tool for Identification of Primers for Multiple Taxa (TipMT), which is a web application to search and design primers for genotyping based on genomic data. The tool identifies and targets single sequence repeats (SSR) or orthologous/taxa-specific genes for genotyping using Multiplex PCR. This pipeline was applied to the genomes of four species of Leishmania (L. amazonensis, L. braziliensis, L. infantum and L. major) and validated by PCR using artificial genomic DNA mixtures of the Leishmania species as templates. This experimental validation demonstrates the reliability of TipMT because amplification profiles showed discrimination of genomic DNA samples from Leishmania species. The TipMT web tool allows for large-scale identification and design of taxon-specific primers and is freely available to the scientific community at http://200.131.37.155/tipMT/ .

  17. Utility of a brief assessment tool developed from the Dizziness Handicap Inventory to screen for Cervicogenic dizziness: A case control study.

    PubMed

    Reid, Susan A; Callister, Robin; Katekar, Michael G; Treleaven, Julia M

    2017-08-01

    Cervicogenic dizziness (CGD) is hard to diagnose as there is no objective test. Can a brief assessment tool be derived from the Dizziness Handicap Inventory (DHI) to assist in screening for CGD? Case-control study with split-sample analysis. 86 people with CGD and 86 people with general dizziness completed the DHI as part of the assessment of their dizziness. Descriptive statistics were used to assess how frequently each question on the DHI was answered 'yes' or 'sometimes' by participants with CGD and by participants with general dizziness. The questions that best discriminated between GCD and general dizziness were compiled into a brief assessment tool for CGD. Data from 80 participants (40 from each group) were used to generate a receiver operating characteristic (ROC) curve to establish a cut-off score for that brief assessment tool. Then, data from the remaining 92 participants were used to try to validate the diagnostic ability of the brief assessment tool using that cut-off score. Questions 1, 9 and 11 were the most discriminatory and were combined to form the brief assessment tool. The ROC curve indicated an optimal threshold of 9. The diagnostic ability of the brief assessment tool among the remaining 46 participants from each group was: sensitivity 77% (95% CI: 67 to 84), specificity 66% (56-75), positive likelihood ratio 2.28 (1.66-3.13), and negative likelihood ratio 0.35 (0.23-0.53). A brief assessment tool of three questions appears to be helpful in screening for CGD. Copyright © 2017. Published by Elsevier Ltd.

  18. Transbronchial Lung Cryobiopsy and Video-assisted Thoracoscopic Lung Biopsy in the Diagnosis of Diffuse Parenchymal Lung Disease. A Meta-analysis of Diagnostic Test Accuracy.

    PubMed

    Iftikhar, Imran H; Alghothani, Lana; Sardi, Alejandro; Berkowitz, David; Musani, Ali I

    2017-07-01

    Transbronchial lung cryobiopsy is increasingly being used for the assessment of diffuse parenchymal lung diseases. Several studies have shown larger biopsy samples and higher yields compared with conventional transbronchial biopsies. However, the higher risk of bleeding and other complications has raised concerns for widespread use of this modality. To study the diagnostic accuracy and safety profile of transbronchial lung cryobiopsy and compare with video-assisted thoracoscopic surgery (VATS) by reviewing available evidence from the literature. Medline and PubMed were searched from inception until December 2016. Data on diagnostic performance were abstracted by constructing two-by-two contingency tables for each study. Data on a priori selected safety outcomes were collected. Risk of bias was assessed with the Quality Assessment of Diagnostic Accuracy Studies tool. Random effects meta-analyses were performed to obtain summary estimates of the diagnostic accuracy. The pooled diagnostic yield, pooled sensitivity, and pooled specificity of transbronchial lung cryobiopsy were 83.7% (76.9-88.8%), 87% (85-89%), and 57% (40-73%), respectively. The pooled diagnostic yield, pooled sensitivity, and pooled specificity of VATS were 92.7% (87.6-95.8%), 91.0% (89-92%), and 58% (31-81%), respectively. The incidence of grade 2 (moderate to severe) endobronchial bleeding after transbronchial lung cryobiopsy and of post-procedural pneumothorax was 4.9% (2.2-10.7%) and 9.5% (5.9-14.9%), respectively. Although the diagnostic test accuracy measures of transbronchial lung cryobiopsy lag behind those of VATS, with an acceptable safety profile and potential cost savings, the former could be considered as an alternative in the evaluation of patients with diffuse parenchymal lung diseases.

  19. Advanced bioanalytics for precision medicine.

    PubMed

    Roda, Aldo; Michelini, Elisa; Caliceti, Cristiana; Guardigli, Massimo; Mirasoli, Mara; Simoni, Patrizia

    2018-01-01

    Precision medicine is a new paradigm that combines diagnostic, imaging, and analytical tools to produce accurate diagnoses and therapeutic interventions tailored to the individual patient. This approach stands in contrast to the traditional "one size fits all" concept, according to which researchers develop disease treatments and preventions for an "average" patient without considering individual differences. The "one size fits all" concept has led to many ineffective or inappropriate treatments, especially for pathologies such as Alzheimer's disease and cancer. Now, precision medicine is receiving massive funding in many countries, thanks to its social and economic potential in terms of improved disease prevention, diagnosis, and therapy. Bioanalytical chemistry is critical to precision medicine. This is because identifying an appropriate tailored therapy requires researchers to collect and analyze information on each patient's specific molecular biomarkers (e.g., proteins, nucleic acids, and metabolites). In other words, precision diagnostics is not possible without precise bioanalytical chemistry. This Trend article highlights some of the most recent advances, including massive analysis of multilayer omics, and new imaging technique applications suitable for implementing precision medicine. Graphical abstract Precision medicine combines bioanalytical chemistry, molecular diagnostics, and imaging tools for performing accurate diagnoses and selecting optimal therapies for each patient.

  20. Mammalian milk allergy: clinical suspicion, cross-reactivities and diagnosis.

    PubMed

    Järvinen, Kirsi M; Chatchatee, Pantipa

    2009-06-01

    Cow's milk allergy affects 2-3% of young children, the economic impact of which necessitates search for simple diagnostic tools and affordable milk substitutes. This review examines recent studies on the diagnosis of cow's milk allergy as well as on the allergenicity of milk from other mammalian species. Resolution of symptoms during strict milk avoidance and their re-appearance during the double-blind, placebo-controlled milk challenge remains the gold standard for the diagnosis of cow's milk allergy. Allergic eosinophilic esophagitis/gastroenteritis requires confirmatory endoscopic biopsy. There are increasing data in various populations on cut-off points based on positive predictive values for skin prick test and milk-specific IgE measurements to aid in the diagnosis of cow's milk allergy and to decrease the number of unnecessary food challenges. For non-IgE-mediated manifestations, noninvasive diagnostic tests are still largely lacking. The significant homology between milk from cow, sheep and goat results in clinical cross-reactivity. However, mare's or donkey's milk may be tolerated by some individuals. Data have been accumulating on the utility of diagnostic tools for mostly IgE-mediated milk allergy and allergenicity of milk from other mammalian species, although further studies are sought.

  1. TummyTrials: A Feasibility Study of Using Self-Experimentation to Detect Individualized Food Triggers.

    PubMed

    Karkar, Ravi; Schroeder, Jessica; Epstein, Daniel A; Pina, Laura R; Scofield, Jeffrey; Fogarty, James; Kientz, Julie A; Munson, Sean A; Vilardaga, Roger; Zia, Jasmine

    2017-05-02

    Diagnostic self-tracking, the recording of personal information to diagnose or manage a health condition, is a common practice, especially for people with chronic conditions. Unfortunately, many who attempt diagnostic self-tracking have trouble accomplishing their goals. People often lack knowledge and skills needed to design and conduct scientifically rigorous experiments, and current tools provide little support. To address these shortcomings and explore opportunities for diagnostic self-tracking, we designed, developed, and evaluated a mobile app that applies a self-experimentation framework to support patients suffering from irritable bowel syndrome (IBS) in identifying their personal food triggers. TummyTrials aids a person in designing, executing, and analyzing self-experiments to evaluate whether a specific food triggers their symptoms. We examined the feasibility of this approach in a field study with 15 IBS patients, finding that participants could use the tool to reliably undergo a self-experiment. However, we also discovered an underlying tension between scientific validity and the lived experience of self-experimentation. We discuss challenges of applying clinical research methods in everyday life, motivating a need for the design of self-experimentation systems to balance rigor with the uncertainties of everyday life.

  2. Models, Measurements, and Local Decisions: Assessing and ...

    EPA Pesticide Factsheets

    This presentation includes a combination of modeling and measurement results to characterize near-source air quality in Newark, New Jersey with consideration of how this information could be used to inform decision making to reduce risk of health impacts. Decisions could include either exposure or emissions reduction, and a host of stakeholders, including residents, academics, NGOs, local and federal agencies. This presentation includes results from the C-PORT modeling system, and from a citizen science project from the local area. The National Exposure Research Laboratory (NERL) Computational Exposure Division (CED) develops and evaluates data, decision-support tools, and models to be applied to media-specific or receptor-specific problem areas. CED uses modeling-based approaches to characterize exposures, evaluate fate and transport, and support environmental diagnostics/forensics with input from multiple data sources. It also develops media- and receptor-specific models, process models, and decision support tools for use both within and outside of EPA.

  3. WRF/CMAQ AQMEII3 Simulations of US Regional-Scale ...

    EPA Pesticide Factsheets

    Chemical boundary conditions are a key input to regional-scale photochemical models. In this study, performed during the third phase of the Air Quality Model Evaluation International Initiative (AQMEII3), we perform annual simulations over North America with chemical boundary conditions prepared from four different global models. Results indicate that the impacts of different boundary conditions are significant for ozone throughout the year and most pronounced outside the summer season. The National Exposure Research Laboratory (NERL) Computational Exposure Division (CED) develops and evaluates data, decision-support tools, and models to be applied to media-specific or receptor-specific problem areas. CED uses modeling-based approaches to characterize exposures, evaluate fate and transport, and support environmental diagnostics/forensics with input from multiple data sources. It also develops media- and receptor-specific models, process models, and decision support tools for use both within and outside of EPA.

  4. Walking on thin ice! Identifying methamphetamine “drug mules” on digital plain radiography

    PubMed Central

    Abdul Rashid, S N; Mohamad Saini, S B; Abdul Hamid, S; Muhammad, S J; Mahmud, R; Thali, M J

    2014-01-01

    Objective: The purpose of this study was to retrospectively evaluate the sensitivity, specificity and accuracy of identifying methamphetamine (MA) internal payloads in “drug mules” by plain abdominal digital radiography (DR). Methods: The study consisted of 35 individuals suspected of internal MA drug containers. A total of 59 supine digital radiographs were collected. An overall calculation regarding the diagnostic accuracy for all “drug mules” and a specific evaluation concerning the radiological appearance of drug packs as well as the rate of clearance and complications in correlation with the reader's experience were performed. The gold standard was the presence of secured drug packs in the faeces. Results: There were 16 true-positive “drug mules” identified. DR of all drug carriers for Group 1 (forensic imaging experienced readers, n = 2) exhibited a sensitivity of 100%, a mean specificity of 76.3%, positive predictive value (PPV) of 78.5%, negative predictive value (NPV) of 100% and a mean accuracy 87.2%. Group 2 (inexperienced readers, n = 3) showed a lower sensitivity (93.7%), a mean specificity of 86%, a PPV of 86.5%, an NPV of 94.1% and a mean accuracy of 89.5%. The interrater agreement within Group 1 was 0.72 and within Group 2 averaged to 0.79, indicating a fair to very good agreement. Conclusion: DR is a valuable screening tool in cases of MA body packers with huge internal payloads being associated with a high diagnostic insecurity. Diagnostic insecurity on plain films may be overcome by low-dose CT as a cross-sectional imaging modality and addressed by improved radiological education in reporting drug carriers on imaging. Advances in knowledge: Diagnostic signs (double-condom and halo signs) on digital plain radiography are specific in MA “drug mules”, although DR is associated with high diagnostic insecurity and underreports the total internal payload. PMID:24472728

  5. Target prioritization and strategy selection for active case-finding of pulmonary tuberculosis: a tool to support country-level project planning.

    PubMed

    Nishikiori, Nobuyuki; Van Weezenbeek, Catharina

    2013-02-02

    Despite the progress made in the past decade, tuberculosis (TB) control still faces significant challenges. In many countries with declining TB incidence, the disease tends to concentrate in vulnerable populations that often have limited access to health care. In light of the limitations of the current case-finding approach and the global urgency to improve case detection, active case-finding (ACF) has been suggested as an important complementary strategy to accelerate tuberculosis control especially among high-risk populations. The present exercise aims to develop a model that can be used for county-level project planning. A simple deterministic model was developed to calculate the number of estimated TB cases diagnosed and the associated costs of diagnosis. The model was designed to compare cost-effectiveness parameters, such as the cost per case detected, for different diagnostic algorithms when they are applied to different risk populations. The model was transformed into a web-based tool that can support national TB programmes and civil society partners in designing ACF activities. According to the model output, tuberculosis active case-finding can be a costly endeavor, depending on the target population and the diagnostic strategy. The analysis suggests the following: (1) Active case-finding activities are cost-effective only if the tuberculosis prevalence among the target population is high. (2) Extensive diagnostic methods (e.g. X-ray screening for the entire group, use of sputum culture or molecular diagnostics) can be applied only to very high-risk groups such as TB contacts, prisoners or people living with human immunodeficiency virus (HIV) infection. (3) Basic diagnostic approaches such as TB symptom screening are always applicable although the diagnostic yield is very limited. The cost-effectiveness parameter was sensitive to local diagnostic costs and the tuberculosis prevalence of target populations. The prioritization of appropriate target populations and careful selection of cost-effective diagnostic strategies are critical prerequisites for rational active case-finding activities. A decision to conduct such activities should be based on the setting-specific cost-effectiveness analysis and programmatic assessment. A web-based tool was developed and is available to support national tuberculosis programmes and partners in the formulation of cost-effective active case-finding activities at the national and subnational levels.

  6. Diagnostic Performance of CT for Diagnosis of Fat-Poor Angiomyolipoma in Patients With Renal Masses: A Systematic Review and Meta-Analysis.

    PubMed

    Woo, Sungmin; Suh, Chong Hyun; Cho, Jeong Yeon; Kim, Sang Youn; Kim, Seung Hyup

    2017-11-01

    The purpose of this article is to systematically review and perform a meta-analysis of the diagnostic performance of CT for diagnosis of fat-poor angiomyolipoma (AML) in patients with renal masses. MEDLINE and EMBASE were systematically searched up to February 2, 2017. We included diagnostic accuracy studies that used CT for diagnosis of fat-poor AML in patients with renal masses, using pathologic examination as the reference standard. Two independent reviewers assessed the methodologic quality using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity of included studies were calculated and were pooled and plotted in a hierarchic summary ROC plot. Sensitivity analyses using several clinically relevant covariates were performed to explore heterogeneity. Fifteen studies (2258 patients) were included. Pooled sensitivity and specificity were 0.67 (95% CI, 0.48-0.81) and 0.97 (95% CI, 0.89-0.99), respectively. Substantial and considerable heterogeneity was present with regard to sensitivity and specificity (I 2 = 91.21% and 78.53%, respectively). At sensitivity analyses, the specificity estimates were comparable and consistently high across all subgroups (0.93-1.00), but sensitivity estimates showed significant variation (0.14-0.82). Studies using pixel distribution analysis (n = 3) showed substantially lower sensitivity estimates (0.14; 95% CI, 0.04-0.40) compared with the remaining 12 studies (0.81; 95% CI, 0.76-0.85). CT shows moderate sensitivity and excellent specificity for diagnosis of fat-poor AML in patients with renal masses. When methods other than pixel distribution analysis are used, better sensitivity can be achieved.

  7. Diagnosing Chronic Pancreatitis: Comparison and Evaluation of Different Diagnostic Tools.

    PubMed

    Issa, Yama; van Santvoort, Hjalmar C; van Dieren, Susan; Besselink, Marc G; Boermeester, Marja A; Ahmed Ali, Usama

    2017-10-01

    This study aims to compare the M-ANNHEIM, Büchler, and Lüneburg diagnostic tools for chronic pancreatitis (CP). A cross-sectional analysis of the development of CP was performed in a prospectively collected multicenter cohort including 669 patients after a first episode of acute pancreatitis. We compared the individual components of the M-ANNHEIM, Büchler, and Lüneburg tools, the agreement between tools, and estimated diagnostic accuracy using Bayesian latent-class analysis. A total of 669 patients with acute pancreatitis followed-up for a median period of 57 (interquartile range, 42-70) months were included. Chronic pancreatitis was diagnosed in 50 patients (7%), 59 patients (9%), and 61 patients (9%) by the M-ANNHEIM, Lüneburg, and Büchler tools, respectively. The overall agreement between these tools was substantial (κ = 0.75). Differences between the tools regarding the following criteria led to significant changes in the total number of diagnoses of CP: abdominal pain, recurrent pancreatitis, moderate to marked ductal lesions, endocrine and exocrine insufficiency, pancreatic calcifications, and pancreatic pseudocysts. The Büchler tool had the highest sensitivity (94%), followed by the M-ANNHEIM (87%), and finally the Lüneburg tool (81%). Differences between diagnostic tools for CP are mainly attributed to presence of clinical symptoms, endocrine insufficiency, and certain morphological complications.

  8. Serial combination of non-invasive tools improves the diagnostic accuracy of severe liver fibrosis in patients with NAFLD.

    PubMed

    Petta, S; Wong, V W-S; Cammà, C; Hiriart, J-B; Wong, G L-H; Vergniol, J; Chan, A W-H; Di Marco, V; Merrouche, W; Chan, H L-Y; Marra, F; Le-Bail, B; Arena, U; Craxì, A; de Ledinghen, V

    2017-09-01

    The accuracy of available non-invasive tools for staging severe fibrosis in patients with nonalcoholic fatty liver disease (NAFLD) is still limited. To assess the diagnostic performance of paired or serial combination of non-invasive tools in NAFLD patients. We analysed data from 741 patients with a histological diagnosis of NAFLD. The GGT/PLT, APRI, AST/ALT, BARD, FIB-4, and NAFLD Fibrosis Score (NFS) scores were calculated according to published algorithms. Liver stiffness measurement (LSM) was performed by FibroScan. LSM, NFS and FIB-4 were the best non-invasive tools for staging F3-F4 fibrosis (AUC 0.863, 0.774, and 0.792, respectively), with LSM having the highest sensitivity (90%), and the highest NPV (94%), and NFS and FIB-4 the highest specificity (97% and 93%, respectively), and the highest PPV (73% and 79%, respectively). The paired combination of LSM or NFS with FIB-4 strongly reduced the likelihood of wrongly classified patients (ranging from 2.7% to 2.6%), at the price of a high uncertainty area (ranging from 54.1% to 58.2%), and of a low overall accuracy (ranging from 43% to 39.1%). The serial combination with the second test used in patients in the grey area of the first test and in those with high LSM values (>9.6 KPa) or low NFS or FIB-4 values (<-1.455 and <1.30, respectively) overall increased the diagnostic performance generating an accuracy ranging from 69.8% to 70.1%, an uncertainty area ranging from 18.9% to 20.4% and a rate of wrong classification ranging from 9.2% to 11.3%. The serial combination of LSM with FIB-4/NFS has a good diagnostic accuracy for the non-invasive diagnosis of severe fibrosis in NAFLD. © 2017 John Wiley & Sons Ltd.

  9. Sensitivity and specificity of a briefer version of the Cambridge Cognitive Examination (CAMCog-Short) in the detection of cognitive decline in the elderly: An exploratory study.

    PubMed

    Radanovic, Marcia; Facco, Giuliana; Forlenza, Orestes V

    2018-05-01

    To create a reduced and briefer version of the widely used Cambridge Cognitive Examination (CAMCog) battery as a concise cognitive test to be used in primary and secondary levels of health care to detect cognitive decline. Our aim was to reduce the administration time of the original test while maintaining its diagnostic accuracy. On the basis of the analysis of 835 CAMCog tests performed by 429 subjects (107 controls, 192 mild cognitive impairment [MCI], and 130 dementia patients), we extracted items that most contributed to intergroup differentiation, according to 2 educational levels (≤8 and >8 y of formal schooling). The final 33-item "low education" and 24-item"high education" CAMCog-Short correspond to 48.5% and 35% of the original version and yielded similar rates of accuracy: area under ROC curves (AUC) > 0.9 in the differentiation between controls × dementia and MCI × dementia (sensitivities > 75%; specificities > 90%); AUC > 0.7 for the differentiation between controls and MCI (sensitivities > 65%; specificities > 75%). The CAMCog-Short emerges as a promising tool for a brief, yet sufficiently accurate, screening tool for use in clinical settings. Further prospective studies designed to validate its diagnostic accuracy are needed. Copyright © 2018 John Wiley & Sons, Ltd.

  10. Serum Adenosine Deaminase (ADA) Activity: A Novel Screening Test to Differentiate HIV Monoinfection From HIV-HBV and HIV-HCV Coinfections.

    PubMed

    Abdi, Mohammad; Rahbari, Rizgar; Khatooni, Zahed; Naseri, Nima; Najafi, Adel; Khodadadi, Iraj

    2016-05-01

    CD4(+) cell count, the common HIV infection screening test, is costly and unable to differentiate HIV monoinfection from its concurrent infection with hepatitis B or C virus. We aimed to ascertain diagnostic value of serum adenosine deaminase (ADA) activity as a useful tool to differentiate HIV mono- and co-infection. Blood samples were collected from 30 HIV-HBV and 30 HIV-HCV coinfected patients, 33 HIV positive subjects, and 72 controls. CD4(+) cell count, serum total ADA (tADA), and ADA1, and ADA2 isoenzyme activities were determined and their sensitivity and specificity were computed. tADA and ADA2 activities were significantly higher and CD4(+) counts were markedly lower in all patients compared with controls. Strong inverse agreements between CD4(+) cell counts and both tADA and ADA2 activities were observed. Serum tADA and ADA1 activities showed the highest specificity and the highest sensitivity, respectively, for differentiating HIV monoinfection from HIV-HBV and HIV-HCV coinfections. We showed strong agreement and correlation between CD4(+) cell count and ADA enzyme activity. Based on high ADA sensitivity and specificity, it is concluded that determination of ADA activity might be a novel diagnostic tool to distinguish of HIV monoinfection from its coinfection with HBV or HCV. © 2015 Wiley Periodicals, Inc.

  11. CANcer-specific Evaluation System (CANES): a high-accuracy platform, for preclinical single/multi-biomarker discovery

    PubMed Central

    Kwon, Min-Seok; Nam, Seungyoon; Lee, Sungyoung; Ahn, Young Zoo; Chang, Hae Ryung; Kim, Yon Hui; Park, Taesung

    2017-01-01

    The recent creation of enormous, cancer-related “Big Data” public depositories represents a powerful means for understanding tumorigenesis. However, a consistently accurate system for clinically evaluating single/multi-biomarkers remains lacking, and it has been asserted that oft-failed clinical advancement of biomarkers occurs within the very early stages of biomarker assessment. To address these challenges, we developed a clinically testable, web-based tool, CANcer-specific single/multi-biomarker Evaluation System (CANES), to evaluate biomarker effectiveness, across 2,134 whole transcriptome datasets, from 94,147 biological samples (from 18 tumor types). For user-provided single/multi-biomarkers, CANES evaluates the performance of single/multi-biomarker candidates, based on four classification methods, support vector machine, random forest, neural networks, and classification and regression trees. In addition, CANES offers several advantages over earlier analysis tools, including: 1) survival analysis; 2) evaluation of mature miRNAs as markers for user-defined diagnostic or prognostic purposes; and 3) provision of a “pan-cancer” summary view, based on each single marker. We believe that such “landscape” evaluation of single/multi-biomarkers, for diagnostic therapeutic/prognostic decision-making, will be highly valuable for the discovery and “repurposing” of existing biomarkers (and their specific targeted therapies), leading to improved patient therapeutic stratification, a key component of targeted therapy success for the avoidance of therapy resistance. PMID:29050243

  12. A novel classification of prostate specific antigen (PSA) biosensors based on transducing elements.

    PubMed

    Najeeb, Mansoor Ani; Ahmad, Zubair; Shakoor, R A; Mohamed, A M A; Kahraman, Ramazan

    2017-06-01

    During the last few decades, there has been a tremendous rise in the number of research studies dedicated towards the development of diagnostic tools based on bio-sensing technology for the early detection of various diseases like cardiovascular diseases (CVD), many types of cancer, diabetes mellitus (DM) and many infectious diseases. Many breakthroughs have been developed in the areas of improving specificity, selectivity and repeatability of the biosensor devices. Innovations in the interdisciplinary areas like biotechnology, genetics, organic electronics and nanotechnology also had a great positive impact on the growth of bio-sensing technology. As a product of these improvements, fast and consistent sensing policies have been productively created for precise and ultrasensitive biomarker-based disease diagnostics. Prostate-specific antigen (PSA) is widely considered as an important biomarker used for diagnosing prostate cancer. There have been many publications based on various biosensors used for PSA detection, but a limited review was available for the classification of these biosensors used for the detection of PSA. This review highlights the various biosensors used for PSA detection and proposes a novel classification for PSA biosensors based on the transducer type used. We also highlight the advantages, disadvantages and limitations of each technique used for PSA biosensing which will make this article a complete reference tool for the future researches in PSA biosensing. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Seminal plasma as a diagnostic fluid for male reproductive system disorders.

    PubMed

    Drabovich, Andrei P; Saraon, Punit; Jarvi, Keith; Diamandis, Eleftherios P

    2014-05-01

    Molecular biomarkers hold promise to advance the noninvasive diagnosis of male reproductive system disorders and facilitate the identification and management of these conditions through screening, early diagnosis and more accurate prognosis. Seminal plasma has great potential as a proximal fluid for protein biomarker discovery and as a clinical sample for noninvasive diagnostics. The seminal plasma proteome contains thousands of proteins and includes a large number of tissue-specific proteins that might accurately indicate a pathological process in the tissue of origin. Potential protein biomarkers for male reproductive system disorders are more abundant in seminal plasma than in blood serum or urine, and, therefore, are more easily identified and quantified in semen by mass spectrometry and other techniques. These methods have enabled elaboration of the composition of the seminal plasma proteome and the tissue specificity of seminal plasma proteins. Strategies have been developed to discover protein biomarkers in seminal plasma through integrated 'omics' approaches. Biomarkers of male infertility and prostate cancer are now emerging, and it is evident that seminal plasma has the potential to complement other diagnostic tools available in urology clinics.

  14. Physical Examination of the Wrist: Useful Provocative Maneuvers.

    PubMed

    Kleinman, William B

    2015-07-01

    Chronic wrist pain resulting from partial interosseous ligament injury remains a diagnostic dilemma for many hand and orthopedic surgeons. Overuse of costly diagnostic studies including magnetic resonance imaging, computed tomography scans, and bone scans can be further frustrating to the clinician because of their inconsistent specificity and reliability in these cases. Physical diagnosis is an effective (and underused) means of establishing a working diagnosis of partial ligament injury to the wrist. Carefully performed provocative maneuvers can be used by the clinician to reproduce the precise character of a patient's problem, reliably establish a working diagnosis, and initiate a plan of treatment. Using precise physical examination techniques, the examiner introduces energy into the wrist in a manner that puts load on specific support ligaments of the carpus, leading to an accurate diagnosis. This article provides a broad spectrum of physical diagnostic tools to help the surgeon develop a working diagnosis of partial wrist ligament injuries in the face of chronic wrist pain and normal x-rays. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  15. Recommendations on nuclear and multimodality imaging in IE and CIED infections.

    PubMed

    Erba, Paola Anna; Lancellotti, Patrizio; Vilacosta, Isidre; Gaemperli, Oliver; Rouzet, Francois; Hacker, Marcus; Signore, Alberto; Slart, Riemer H J A; Habib, Gilbert

    2018-05-24

    In the latest update of the European Society of Cardiology (ESC) guidelines for the management of infective endocarditis (IE), imaging is positioned at the centre of the diagnostic work-up so that an early and accurate diagnosis can be reached. Besides echocardiography, contrast-enhanced CT (ce-CT), radiolabelled leucocyte (white blood cell, WBC) SPECT/CT and [ 18 F]FDG PET/CT are included as diagnostic tools in the diagnostic flow chart for IE. Following the clinical guidelines that provided a straightforward message on the role of multimodality imaging, we believe that it is highly relevant to produce specific recommendations on nuclear multimodality imaging in IE and cardiac implantable electronic device infections. In these procedural recommendations we therefore describe in detail the technical and practical aspects of WBC SPECT/CT and [ 18 F]FDG PET/CT, including ce-CT acquisition protocols. We also discuss the advantages and limitations of each procedure, specific pitfalls when interpreting images, and the most important results from the literature, and also provide recommendations on the appropriate use of multimodality imaging.

  16. Criterion and concurrent validity of Conners Adult ADHD Diagnostic Interview for DSM-IV (CAADID) Spanish version.

    PubMed

    Ramos-Quiroga, Josep Antoni; Bosch, Rosa; Richarte, Vanesa; Valero, Sergi; Gómez-Barros, Nuria; Nogueira, Mariana; Palomar, Gloria; Corrales, Montse; Sáez-Francàs, Naia; Corominas, Margarida; Real, Alberto; Vidal, Raquel; Chalita, Pablo J; Casas, Miguel

    2012-01-01

    Attention deficit hyperactivity disorder (ADHD) is a common neuropsychiatric disorder in adulthood. Its diagnosis requires a retrospective evaluation of ADHD symptoms in childhood, the continuity of these symptoms in adulthood, and a differential diagnosis. For these reasons, diagnosis of ADHD in adults is a complex process which needs effective diagnostic tools. To analyse the criterion validity of the CAADID semi-structured interview, Spanish version, and the concurrent validity compared with other ADHD severity scales. An observational case-control study was conducted on 691 patients with ADHD. They were out-patients treated in a program for adults with ADHD in a hospital. A sensitivity of 98.86%, specificity 67.68%, positive predictive value 90.77% and a negative predictive value 94.87% were observed. Diagnostic precision was 91.46%. The kappa index concordance between the clinical diagnostic interview and the CAADID was 0.88. Good concurrent validity was obtained, the CAADID correlated significantly with WURS scale (r=0.522, P<.01), ADHD Rating Scale (r=0.670, P<.0.1) and CAARS (self-rating version; r=0.656, P<.01 and observer-report r=0.514, P<.01). CAADID is a valid and useful tool for the diagnosis of ADHD in adults for clinical, as well as for research purposes. Copyright © 2012 SEP y SEPB. Published by Elsevier España, S.L. All rights reserved.

  17. Discovery of putative salivary biomarkers for Sjögren's syndrome using high resolution mass spectrometry and bioinformatics.

    PubMed

    Zoukhri, Driss; Rawe, Ian; Singh, Mabi; Brown, Ashley; Kublin, Claire L; Dawson, Kevin; Haddon, William F; White, Earl L; Hanley, Kathleen M; Tusé, Daniel; Malyj, Wasyl; Papas, Athena

    2012-03-01

    The purpose of the current study was to determine if saliva contains biomarkers that can be used as diagnostic tools for Sjögren's syndrome (SjS). Twenty seven SjS patients and 27 age-matched healthy controls were recruited for these studies. Unstimulated glandular saliva was collected from the Wharton's duct using a suction device. Two µl of salvia were processed for mass spectrometry analyses on a prOTOF 2000 matrix-assisted laser desorption/ionization orthogonal time of flight (MALDI O-TOF) mass spectrometer. Raw data were analyzed using bioinformatic tools to identify biomarkers. MALDI O-TOF MS analyses of saliva samples were highly reproducible and the mass spectra generated were very rich in peptides and peptide fragments in the 750-7,500 Da range. Data analysis using bioinformatic tools resulted in several classification models being built and several biomarkers identified. One model based on 7 putative biomarkers yielded a sensitivity of 97.5%, specificity of 97.8% and an accuracy of 97.6%. One biomarker was present only in SjS samples and was identified as a proteolytic peptide originating from human basic salivary proline-rich protein 3 precursor. We conclude that salivary biomarkers detected by high-resolution mass spectrometry coupled with powerful bioinformatic tools offer the potential to serve as diagnostic/prognostic tools for SjS.

  18. Development and validation of an epitope-blocking ELISA using an anti-haemagglutinin monoclonal antibody for specific detection of antibodies in sheep and goat sera directed against peste des petits ruminants virus.

    PubMed

    Bodjo, Sanne Charles; Baziki, Jean-de-Dieu; Nwankpa, Nick; Chitsungo, Ethel; Koffi, Yao Mathurin; Couacy-Hymann, Emmanuel; Diop, Mariame; Gizaw, Daniel; Tajelser, Idris Badri Adam; Lelenta, Mamadou; Diallo, Adama; Tounkara, Karim

    2018-07-01

    Peste des petits ruminants (PPR) is a contagious and economically important disease affecting production of small ruminants (i.e., sheep and goats). Taking into consideration the lessons learnt from the Global Rinderpest Eradication Programme (GREP), PPR is now targeted by the international veterinary community as the next animal disease to be eradicated. To support the African continental programme for the control of PPR, the Pan African Veterinary Vaccine Centre of the African Union (AU-PANVAC) is developing diagnostics tools. Here, we describe the development of a blocking enzyme-linked immunosorbent assay (bELISA) that allows testing of a large number of samples for specific detection of antibodies directed against PPR virus in sheep and goat sera. The PPR bELISA uses an anti-haemagglutinin (H) monoclonal antibody (MAb) as a competitor antibody, and tests results are interpreted using the percentage of inhibition (PI) of MAb binding generated by the serum sample. PI values below or equal to 18% (PI ≤ 18%) are negative, PI values greater than or equal to 25% (PI ≥ 25%) are positive, and PI values greater than 18% and below 25% are doubtful. The diagnostic specificity (DSp) and diagnostic sensitivity (DSe) were found to be 100% and 93.74%, respectively. The H-based PPR-bELISA showed good correlation with the virus neutralization test (VNT), the gold standard test, with a kappa value of 0.947. The H-based PPR-bELISA is more specific than the commercial kit ID Screen® PPR Competition (N-based PPR-cELISA) from IDvet (France), but the commercial kit is slightly more sensitive than the H-based PPR-bELISA. The validation process also indicated good repeatability and reproducibility of the H-based PPR-bELISA, making this new test a suitable tool for the surveillance and sero-monitoring of the vaccination campaign.

  19. MO-AB-210-03: Workshop [Advancements in high intensity focused ultrasound

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, Z.

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrationsmore » with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.« less

  20. MO-AB-210-02: Ultrasound Imaging and Therapy-Hands On Workshop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sammet, S.

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrationsmore » with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.« less

  1. MO-AB-210-01: Ultrasound Imaging and Therapy-Hands On Workshop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, Z.

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrationsmore » with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.« less

  2. A case definition and photographic screening tool for the facial phenotype of fetal alcohol syndrome.

    PubMed

    Astley, S J; Clarren, S K

    1996-07-01

    The purpose of this study was to demonstrate that a quantitative, multivariate case definition of the fetal alcohol syndrome (FAS) facial phenotype could be derived from photographs of individuals with FAS and to demonstrate how this case definition and photographic approach could be used to develop efficient, accurate, and precise screening tools, diagnostic aids, and possibly surveillance tools. Frontal facial photographs of 42 subjects (from birth to 27 years of age) with FAS were matched to 84 subjects without FAS. The study population was randomly divided in half. Group 1 was used to identify the facial features that best differentiated individuals with and without FAS. Group 2 was used for cross validation. In group 1, stepwise discriminant analysis identified three facial features (reduced palpebral fissure length/inner canthal distance ratio, smooth philtrum, and thin upper lip) as the cluster of features that differentiated individuals with and without FAS in groups 1 and 2 with 100% accuracy. Sensitivity and specificity were unaffected by race, gender, and age. The phenotypic case definition derived from photographs accurately distinguished between individuals with and without FAS, demonstrating the potential of this approach for developing screening, diagnostic, and surveillance tools. Further evaluation of the validity and generalizability of this method will be needed.

  3. Diagnosing leprosy: revisiting the role of the slit-skin smear with critical analysis of the applicability of polymerase chain reaction in diagnosis.

    PubMed

    Banerjee, Surajita; Biswas, Nibir; Kanti Das, Nilay; Sil, Amrita; Ghosh, Pramit; Hasanoor Raja, Abu Hena; Dasgupta, Sarbani; Kanti Datta, Pijush; Bhattacharya, Basudev

    2011-12-01

    Diagnosing leprosy is challenging, especially in early-stage cases, and the need for a sensitive diagnostic tool is urgent. Polymerase chain reaction (PCR) holds promise as a simple and sensitive diagnostic tool, but its usefulness in the Indian context requires further evaluation. Slit-skin smear (SSS) remains the conventional method of leprosy detection. Hence, this study was undertaken to evaluate and compare the diagnostic efficacy of PCR versus that of SSS. Punch biopsy of skin and SSS were obtained from the active margins of lesions. Cases were clinically grouped according to whether they were multibacillary (MB) or paucibacillary (PB) and classified into tuberculoid (TT), borderline tuberculoid (BT), borderline lepromatous (BL), lepromatous (LL), histoid, and indeterminate groups after clinicopathological correlation. DNA was extracted from biopsy specimens, and multiplex PCR was carried out incorporating primers intended for the amplification of a specific 372-bp fragment of a repetitive sequence of Mycobacterium leprae DNA. Among 164 patients, PCR was positive in 82.3%. The sensitivity of PCR was significantly greater (P < 0.0001) than that of SSS in both the MB (85.9% vs. 59.8%) and PB (75.4% vs. 1.8%) subgroups; the difference in sensitivity in the PB subgroup is remarkable. Positivity by PCR and SSS was found in 100% of LL and histoid leprosy, but PCR had significantly greater (P < 0.0001) positivity in BT leprosy and was of definite increased value in indeterminate and TT leprosy. Polymerase chain reaction had higher sensitivity compared with SSS, especially in diagnostically challenging and PB cases. Thus, the use of this costly but sensitive tool should be restricted to this subgroup, because SSS is sufficiently sensitive in the diagnosis of LL and histoid leprosy. © 2011 The International Society of Dermatology.

  4. Latest generation of flat detector CT as a peri-interventional diagnostic tool: a comparative study with multidetector CT.

    PubMed

    Leyhe, Johanna Rosemarie; Tsogkas, Ioannis; Hesse, Amélie Carolina; Behme, Daniel; Schregel, Katharina; Papageorgiou, Ismini; Liman, Jan; Knauth, Michael; Psychogios, Marios-Nikos

    2017-12-01

    Flat detector CT (FDCT) has been used as a peri-interventional diagnostic tool in numerous studies with mixed results regarding image quality and detection of intracranial lesions. We compared the diagnostic aspects of the latest generation FDCT with standard multidetector CT (MDCT). 102 patients were included in our retrospective study. All patients had undergone interventional procedures. FDCT was acquired peri-interventionally and compared with postinterventional MDCT regarding depiction of ventricular/subarachnoidal spaces, detection of intracranial hemorrhage, and delineation of ischemic lesions using an ordinal scale. Ischemic lesions were quantified with the Alberta Stroke Program Early CT Scale (ASPECTS) on both examinations. Two neuroradiologists with varying grades of experience and a medical student scored the anonymized images separately, blinded to the clinical history. The two methods were of equal diagnostic value regarding evaluation of the ventricular system and the subarachnoidal spaces. Subarachnoidal, intraventricular, and parenchymal hemorrhages were detected with a sensitivity of 95%, 97%, and 100% and specificity of 97%, 100%, and 99%, respectively, using FDCT. Gray-white differentiation was feasible in the majority of FDCT scans, and ischemic lesions were detected with a sensitivity of 71% on FDCT, compared with MDCT scans. The mean difference in ASPECTS values on FDCT and MDCT was 0.5 points (95% CI 0.12 to 0.88). The latest generation of FDCT is a reliable and accurate tool for the detection of intracranial hemorrhage. Gray-white differentiation is feasible in the supratentorial region. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  5. Diagnosis and Management of Patients with Paroxysmal Sympathetic Hyperactivity following Acute Brain Injuries Using a Consensus-Based Diagnostic Tool: A Single Institutional Case Series.

    PubMed

    Godo, Shigeo; Irino, Shigemi; Nakagawa, Atsuhiro; Kawazoe, Yu; Fujita, Motoo; Kudo, Daisuke; Nomura, Ryosuke; Shimokawa, Hiroaki; Kushimoto, Shigeki

    2017-09-01

    Paroxysmal sympathetic hyperactivity (PSH) is a distinct syndrome of episodic sympathetic hyperactivities following severe acquired brain injury, characterized by paroxysmal transient fever, tachycardia, hypertension, tachypnea, excessive diaphoresis and specific posturing. PSH remains to be an under-recognized condition with a diagnostic pitfall especially in the intensive care unit (ICU) settings due to the high prevalence of concomitant diseases that mimic PSH. A consensus set of diagnostic criteria named PSH-Assessment Measure (PSH-AM) has been developed recently, which is consisted of two components: a diagnosis likelihood tool derived from clinical characteristics of PSH, and a clinical feature scale assigned to the severity of each sympathetic hyperactivity. We herein present a case series of patients with PSH who were diagnosed and followed by using PSH-AM in our tertiary institutional medical and surgical ICU between April 2015 and March 2017 in order to evaluate the clinical efficacy of PSH-AM. Among 394 survivors of 521 patients admitted with acquired brain injury defined as acute brain injury at all levels of severity regardless of the presence of altered consciousness, including traumatic brain injury, stroke, infectious disease, and encephalopathy, 6 patients (1.5%) were diagnosed as PSH by using PSH-AM. PSH-AM served as a useful scoring system for early objective diagnosis, assessment of severity, and serial evaluation of treatment efficacy in the management of PSH in the ICU settings. In conclusion, critical care clinicians should consider the possibility of PSH and can use PSH-AM as a useful diagnostic and guiding tool in the management of PSH.

  6. Impact of the US Patent System on the promise of personalized medicine.

    PubMed

    Solomon, Louis M; Sieczkiewicz, Gregory J

    2007-09-01

    The biotechnology revolution promises unfathomable future scientific discovery. One of the potential benefits is the accelerated introduction of new diagnostics and treatments to the general public. The right medication for the right patient is the goal of personalized medicine, which directly benefits from many of biotechnology's biggest and most recent advances. The US patent system rewards innovation in medicine and other arts and sciences by granting innovators, for a period of time, the right to exclude others from using what was invented. One of the purposes of the patent system is to trade that right to exclude, and in its stead obtain the patent holder's obligation to fully and publicly disclose the essence of the innovations so that they can be improved, thus advancing the common welfare. A tension exists between personalized medicine's need for access to and use of scientific advances and the patent system's reward of exclusive use or nonuse to innovators. This tension may result in fewer diagnostic and therapeutic tools brought to the market and generally adopted. The risk seems particularly acute with respect to the diagnostic and therapeutic tools arising from genetic testing that hold specific value for a subset of the population. The judicial system has introduced ethical exceptions that overcome a patent holder's right to exclude; these judicial overrides relate to the provision of certain types of medical procedures and the development of certain types of new drugs, and not, apparently, to the use of diagnostic and therapeutic tools essential to the success of personalized medicine. A serious question exists as to whether legislative action is necessary to increase public access to genetic testing.

  7. Blood culture-negative endocarditis: Improving the diagnostic yield using new diagnostic tools.

    PubMed

    Fournier, Pierre-Edouard; Gouriet, Frédérique; Casalta, Jean-Paul; Lepidi, Hubert; Chaudet, Hervé; Thuny, Franck; Collart, Frédéric; Habib, Gilbert; Raoult, Didier

    2017-11-01

    Blood culture-negative endocarditis (BCNE) may represent up to 70% of all endocarditis cases, depending on series. From 2001 to 2009, we implemented in our laboratory a multimodal diagnostic strategy for BCNE that included systematized testing of blood, and when available, valvular biopsy specimens using serological, broad range molecular, and histopathological assays. A causative microorganism was identified in 62.7% of patients.In this study from January 2010 to December 2015, in an effort to increase the number of identified causative microorganisms, we prospectively added to our diagnostic protocol specific real-time (RT) polymerase chain reaction (PCR) assays targeting various endocarditis agents, and applied them to all patients with BCNE admitted to the 4 public hospitals in Marseille, France.A total of 283 patients with BCNE were included in the study. Of these, 177 were classified as having definite endocarditis. Using our new multimodal diagnostic strategy, we identified an etiology in 138 patients (78.0% of cases). Of these, 3 were not infective (2.2%) and 1 was diagnosed as having Mycobacterium bovis BCG endocarditis. By adding specific PCR assays from blood and valvular biopsies, which exhibited a significantly greater sensitivity (P < 10) than other methods, causative agents, mostly enterococci, streptococci, and zoonotic microorganisms, were identified in an additional 27 patients (14 from valves only, 11 from blood only, and 2 from both). Finally, in another 107 patients, a pathogen was detected using serology in 37, valve culture in 8, broad spectrum PCR from valvular biopsies and blood in 19 and 2, respectively, immunohistochemistry from valves in 3, and a combination of several assays in 38.By adding specific RT-PCR assays to our systematic PCR testing of patients with BCNE, we increased the diagnostic efficiency by 24.3%, mostly by detecting enterococci and streptococci that had not been detected by other diagnostic methods, but also agents requiring specific management such as Mycoplasma hominis and Tropheryma whipplei. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  8. Reliability and diagnostic characteristics of the JFK coma recovery scale-revised: exploring the influence of rater's level of experience.

    PubMed

    Løvstad, Marianne; Frøslie, Kathrine F; Giacino, Joseph T; Skandsen, Toril; Anke, Audny; Schanke, Anne-Kristine

    2010-01-01

    To confirm the reliability and diagnostic validity of the JFK Coma Recovery Scale-Revised (CRS-R) across raters with varying levels of experience. Thirty-one patients with disorders of consciousness were recruited from 6 Norwegian hospitals. CRS-R and the Disability Rating Scale. Reliability measures were good for the CRS-R total scores and moderate to good for its subscales. Diagnostic agreement among examiners was good. Raters' experience with the CRS-R favorably influenced reliability. Sensitivity and specificity analyses demonstrated better detection of patients in minimally conscious state on the CRS-R relative to the Disability Rating Scale. The CRS-R is a reliable tool for diagnosing vegetative state and minimally conscious state. Raters' level of experience influences the reliability of the CRS-R scores.

  9. The treatable intellectual disability APP www.treatable-id.org: a digital tool to enhance diagnosis & care for rare diseases.

    PubMed

    van Karnebeek, Clara D M; Houben, Roderick F A; Lafek, Mirafe; Giannasi, Wynona; Stockler, Sylvia

    2012-07-23

    Intellectual disability (ID) is a devastating and frequent condition, affecting 2-3% of the population worldwide. Early recognition of treatable underlying conditions drastically improves health outcomes and decreases burdens to patients, families and society. Our systematic literature review identified 81 such inborn errors of metabolism, which present with ID as a prominent feature and are amenable to causal therapy. The WebAPP translates this knowledge of rare diseases into a diagnostic tool and information portal. Freely available as a WebAPP via http://www.treatable-id.org and end 2012 via the APP store, this diagnostic tool is designed for all specialists evaluating children with global delay / ID and laboratory scientists. Information on the 81 diseases is presented in different ways with search functions: 15 biochemical categories, neurologic and non-neurologic signs & symptoms, diagnostic investigations (metabolic screening tests in blood and urine identify 65% of all IEM), therapies & effects on primary (IQ/developmental quotient) and secondary outcomes, and available evidence For each rare condition a 'disease page' serves as an information portal with online access to specific genetics, biochemistry, phenotype, diagnostic tests and therapeutic options. As new knowledge and evidence is gained from expert input and PubMed searches this tool will be continually updated. The WebAPP is an integral part of a protocol prioritizing treatability in the work-up of every child with global delay / ID. A 3-year funded study will enable an evaluation of its effectiveness. For rare diseases, a field for which financial and scientific resources are particularly scarce, knowledge translation challenges are abundant. With this WebAPP technology is capitalized to raise awareness for rare treatable diseases and their common presenting clinical feature of ID, with the potential to improve health outcomes. This innovative digital tool is designed to motivate health care providers to search actively for treatable causes of ID, and support an evidence-based approach to rare metabolic diseases. In our current -omics world with continuous information flow, the effective synthesis of data into accessible, clinical knowledge has become ever more essential to bridge the gap between research and care.

  10. The treatable intellectual disability APP www.treatable-id.org: A digital tool to enhance diagnosis & care for rare diseases

    PubMed Central

    2012-01-01

    Background Intellectual disability (ID) is a devastating and frequent condition, affecting 2-3% of the population worldwide. Early recognition of treatable underlying conditions drastically improves health outcomes and decreases burdens to patients, families and society. Our systematic literature review identified 81 such inborn errors of metabolism, which present with ID as a prominent feature and are amenable to causal therapy. The WebAPP translates this knowledge of rare diseases into a diagnostic tool and information portal. Methods & results Freely available as a WebAPP via http://www.treatable-id.org and end 2012 via the APP store, this diagnostic tool is designed for all specialists evaluating children with global delay / ID and laboratory scientists. Information on the 81 diseases is presented in different ways with search functions: 15 biochemical categories, neurologic and non-neurologic signs & symptoms, diagnostic investigations (metabolic screening tests in blood and urine identify 65% of all IEM), therapies & effects on primary (IQ/developmental quotient) and secondary outcomes, and available evidence For each rare condition a ‘disease page’ serves as an information portal with online access to specific genetics, biochemistry, phenotype, diagnostic tests and therapeutic options. As new knowledge and evidence is gained from expert input and PubMed searches this tool will be continually updated. The WebAPP is an integral part of a protocol prioritizing treatability in the work-up of every child with global delay / ID. A 3-year funded study will enable an evaluation of its effectiveness. Conclusions For rare diseases, a field for which financial and scientific resources are particularly scarce, knowledge translation challenges are abundant. With this WebAPP technology is capitalized to raise awareness for rare treatable diseases and their common presenting clinical feature of ID, with the potential to improve health outcomes. This innovative digital tool is designed to motivate health care providers to search actively for treatable causes of ID, and support an evidence-based approach to rare metabolic diseases. In our current –omics world with continuous information flow, the effective synthesis of data into accessible, clinical knowledge has become ever more essential to bridge the gap between research and care. PMID:22824307

  11. Broad-range (pan) Salmonella and Salmonella serotype typhi-specific real-time PCR assays: potential tools for the clinical microbiologist.

    PubMed

    Farrell, John J; Doyle, Laura J; Addison, Rachel M; Reller, L Barth; Hall, Geraldine S; Procop, Gary W

    2005-03-01

    We describe broad-range salmonellae (ie, Salmonella) and Salmonella serotype Typhi-specific LightCycler (Roche Diagnostics, Indianapolis, IN) real-time polymerase chain reaction assays. We validated these with a battery of 280 bacteria, 108 of which were salmonellae representing 20 serotypes. In addition, 298 isolates from 170 clinical specimens that were suspected to possibly represent Salmonella were tested with the pan- Salmonella assay. Finally, the pan-Salmonella assay also was used to test DNA extracts from 101 archived, frozen stool specimens, 55 of which were culture-positive for salmonellae. Both assays were 100% sensitive and specific when cultured isolates of the battery were tested. The pan- Salmonella assay also characterized correctly all salmonellae on the primary isolation agar and was 96% sensitive (53/55) and 96% specific (49/51) when nucleic acid extracts from direct stool specimens were tested. These assays represent potential tools the clinical microbiologist could use to screen suspect isolates or stool specimens for Salmonella.

  12. An electronic thesaurus of Evidence Based Laboratory Medicine hematological and biochemical diagnostic tests.

    PubMed

    Dorizzi, R M; Maconi, M; Giavarina, D; Loza, G; Aman, M; Moreira, J; Bisoffi, Z; Gennuso, C

    2009-10-01

    The adoption of Evidence Based Laboratory Medicine (EBLM) has been hampered until today by the lack of effective tools. The SIMeL EBLM e-Thesaurus (on-line Repertoire of the diagnostic effectiveness of the laboratory, radiology and cardiology test) provides a useful support to clinical laboratory professionals and to clinicians for the interpretation of the diagnostic tests. The e-Thesaurus is an application developed using Microsoft Active Server Pages technology and carried out with Web Server Microsoft Internet Information Server and is available at the SIMeL website using a browser running JavaScript scripts (Internet Explorer is recommended). It contains a database (in Italian, English and Spanish) of the sensitivity and specificity (including the 95% confidence interval), the positive and negative likelihood ratios, the Diagnostic Odds Ratio and the Number Needed to Diagnose of more than 2000 diagnostic (most laboratory but also cardiology and radiology) tests. The e-Thesaurus improves the previous SIMeL paper and CD Thesaurus; its main features are a three languages search and a continuous and an easy updating capability.

  13. Invasive candidiasis: future directions in non-culture based diagnosis.

    PubMed

    Posch, Wilfried; Heimdörfer, David; Wilflingseder, Doris; Lass-Flörl, Cornelia

    2017-09-01

    Delayed initial antifungal therapy is associated with high mortality rates caused by invasive candida infections, since accurate detection of the opportunistic pathogenic yeast and its identification display a diagnostic challenge. diagnosis of candida infections relies on time-consuming methods such as blood cultures, serologic and histopathologic examination. to allow for fast detection and characterization of invasive candidiasis, there is a need to improve diagnostic tools. trends in diagnostics switch to non-culture-based methods, which allow specified diagnosis within significantly shorter periods of time in order to provide early and appropriate antifungal treatment. Areas covered: within this review comprise novel pathogen- and host-related testing methods, e.g. multiplex-PCR analyses, T2 magnetic resonance, fungus-specific DNA microarrays, microRNA characterization or analyses of IL-17 as biomarker for early detection of invasive candidiasis. Expert commentary: Early recognition and diagnosis of fungal infections is a key issue for improved patient management. As shown in this review, a broad range of novel molecular based tests for the detection and identification of Candida species is available. However, several assays are in-house assays and lack standardization, clinical validation as well as data on sensitivity and specificity. This underscores the need for the development of faster and more accurate diagnostic tests.

  14. Image-guided fine-needle aspiration of retroperitoneal masses: The role of the cytopathologist.

    PubMed

    Mehdi, Ghazala; Maheshwari, Veena; Afzal, Sheerin; Ansari, Hena A; Ahmad, Ibne

    2013-01-01

    Retroperitoneal tumors constitute a difficult diagnostic category as they are not easily accessible. The advent of image-guided fine-needle aspiration (FNA) has resolved this problem significantly. We present a short study based on guided aspiration of retroperitoneal tumors, in which we have tried to assess the role of image-guided fine-needle aspiration cytology as a tool for pre-operative diagnosis. The study was conducted on patients diagnosed with retroperitoneal masses. FNA was performed under image guidance with the help of ultrasonography and/or computed tomography; smears were prepared and meticulously screened according to a fixed protocol. The results were analyzed to determine sensitivity, specificity, and diagnostic efficacy of cytopathological diagnosis using image-guided FNA techniques. We assessed 38 patients with retroperitoneal masses. In all cases, adequate cellular material was obtained. No major complications were encountered. Statistical analysis was carried out in 35 cases; sensitivity, specificity, and diagnostic accuracy were 100% in these cases. FNA under image guidance should be considered a first-line diagnostic approach for retroperitoneal and other abdominal tumors, although caution should be exercised in case selection. In areas where advanced tests are not available, the cytotechnologist and cytopathologist have a very important role to play in ensuring accurate diagnoses.

  15. [Microbiological point of care tests].

    PubMed

    Book, Malte; Lehmann, Lutz Eric; Zhang, Xianghong; Stüber, Frank

    2010-11-01

    It is well known that the early initiation of a specific antiinfective therapy is crucial to reduce the mortality in severe infection. Procedures culturing pathogens are the diagnostic gold standard in such diseases. However, these methods yield results earliest between 24 to 48 hours. Therefore, severe infections such as sepsis need to be treated with an empirical antimicrobial therapy, which is ineffective in an unknown fraction of these patients. Today's microbiological point of care tests are pathogen specific and therefore not appropriate for an infection with a variety of possible pathogens. Molecular nucleic acid diagnostics such as polymerase chain reaction (PCR) allow the identification of pathogens and resistances. These methods are used routinely to speed up the analysis of positive blood cultures. The newest PCR based system allows the identification of the 25 most frequent sepsis pathogens by PCR in parallel without previous culture in less than 6 hours. Thereby, these systems might shorten the time of possibly insufficient antiinfective therapy. However, these extensive tools are not suitable as point of care diagnostics. Miniaturization and automating of the nucleic acid based method is pending, as well as an increase of detectable pathogens and resistance genes by these methods. It is assumed that molecular PCR techniques will have an increasing impact on microbiological diagnostics in the future. © Georg Thieme Verlag Stuttgart · New York.

  16. The diagnosis of idiopathic pulmonary fibrosis: current and future approaches

    PubMed Central

    Martinez, Fernando J; Chisholm, Alison; Collard, Harold R; Flaherty, Kevin R; Myers, Jeffrey; Raghu, Ganesh; Walsh, Simon LF; White, Eric S; Richeldi, Luca

    2017-01-01

    With the recent development of two effective treatments for patients with idiopathic pulmonary fibrosis, an accurate diagnosis is crucial. The traditional approach to diagnosis emphasises the importance of thorough clinical and laboratory evaluations to exclude secondary causes of disease. High-resolution CT is a critical initial diagnostic test and acts as a tool to identify patients who should undergo surgical lung biopsy to secure a definitive histological diagnosis of usual interstitial pneumonia pattern. This diagnostic approach faces several challenges. Many patients with suspected idiopathic pulmonary fibrosis present with atypical high-resolution CT characteristics but are unfit for surgical lung biopsy, therefore preventing a confident diagnosis. The state of the art suggests an iterative, multidisciplinary process that incorporates available clinical, laboratory, imaging, and histological features. Recent research has explored genomic techniques to molecularly phenotype patients with interstitial lung disease. In the future, clinicians will probably use blood-specific or lung-specific molecular markers in combination with other clinical, physiological, and imaging features to enhance diagnostic efforts, refine prognostic recommendations, and influence the initial or subsequent treatment options. There is an urgent and increasing need for well designed, large, prospective studies measuring the effect of different diagnostic approaches. Ultimately, this will help to inform the development of guidelines and tailor clinical practice for the benefit of patients. PMID:27932290

  17. Critical comparison of diffuse reflectance spectroscopy and colorimetry as dermatological diagnostic tools for acanthosis nigricans: a chemometric approach.

    PubMed

    Devpura, Suneetha; Pattamadilok, Bensachee; Syed, Zain U; Vemulapalli, Pranita; Henderson, Marsha; Rehse, Steven J; Hamzavi, Iltefat; Lim, Henry W; Naik, Ratna

    2011-06-01

    Quantification of skin changes due to acanthosis nigricans (AN), a disorder common among insulin-resistant diabetic and obese individuals, was investigated using two optical techniques: diffuse reflectance spectroscopy (DRS) and colorimetry. Measurements were obtained from AN lesions on the neck and two control sites of eight AN patients. A principal component/discriminant function analysis successfully differentiated between AN lesion and normal skin with 87.7% sensitivity and 94.8% specificity in DRS measurements and 97.2% sensitivity and 96.4% specificity in colorimetry measurements.

  18. Characteristics of a Cognitive Tool That Helps Students Learn Diagnostic Problem Solving

    ERIC Educational Resources Information Center

    Danielson, Jared A.; Mills, Eric M.; Vermeer, Pamela J.; Preast, Vanessa A.; Young, Karen M.; Christopher, Mary M.; George, Jeanne W.; Wood, R. Darren; Bender, Holly S.

    2007-01-01

    Three related studies replicated and extended previous work (J.A. Danielson et al. (2003), "Educational Technology Research and Development," 51(3), 63-81) involving the Diagnostic Pathfinder (dP) (previously Problem List Generator [PLG]), a cognitive tool for learning diagnostic problem solving. In studies 1 and 2, groups of 126 and 113…

  19. A review of biomarkers for predicting clinical reactivity to foods with a focus on specific immunoglobulin E antibodies.

    PubMed

    Sato, Sakura; Yanagida, Noriyuki; Ohtani, Kiyotaka; Koike, Yumi; Ebisawa, Motohiro

    2015-06-01

    The purpose of this study is to assess the latest studies that focus on specific immunoglobulin (Ig)E antibodies for predicting clinical reactivity to foods. Persistent hen's egg and cow's milk allergy patients have higher antigen-specific IgE levels at all ages than those who have outgrown these allergies. Recent studies on the natural histories of hen's egg and cow's milk allergies suggested that baseline antigen-specific IgEs are the most important predictors of tolerance. Oral immunotherapy (OIT), which is a novel therapeutic approach for food allergy, requires biomarkers for predicting outcomes after therapy. Several studies indicate that the initial antigen-specific IgE level may be a useful biomarker for the prognosis of OIT. Recently, component-resolved diagnostics (CRD) has been used for food allergy diagnosis. Current studies have suggested that Ara h 2, omega-5 gliadin and ovomucoid are good diagnostic markers for peanut, wheat and egg allergies, respectively. Antigen-specific IgE can be a useful biomarker for predicting clinical reactivity to food allergies. Monitoring hen's egg and cow's milk-specific IgE is useful for predicting prognosis, and baseline specific IgE levels may be associated with the outcome of OIT. The use of CRD provides us with a better tool for diagnosing food allergy.

  20. Detection of spring viraemia of carp virus (SVCV) by loop-mediated isothermal amplification (LAMP) in koi carp, Cyprinus carpio L

    USGS Publications Warehouse

    Shivappa, R.B.; Savan, R.; Kono, T.; Sakai, M.; Emmenegger, E.; Kurath, G.; Levine, Jay F.

    2008-01-01

    Spring viraemia of carp virus (SVCV) is a rhabdovirus associated with systemic illness and mortality in cyprinids. Several diagnostic tests are available for detection of SVCV. However, most of these tests are time consuming and are not well adapted for field-based diagnostics. In this study, a diagnostic tool for SVCV detection based on reverse transcription loop-mediated isothermal amplification (RT-LAMP) has been developed. Based on the nucleotide sequence of the glycoprotein (G) gene of SVCV North Carolina (NC) isolate, four sets (each set containing two outer and two inner) of primers were designed. Temperature and time conditions were optimized to 65 ??C and 60 min, respectively, for LAMP and RT-LAMP using one primer set. In vitro specificity was evaluated using four different strains of fish rhabdoviruses and RT-LAMP was found to be specific to SVCV. Serial dilutions of SVCV NC isolate was used to evaluate the in vitro sensitivity of RT-LAMP. Sensitivity of the assays was similar to RT-PCR and detected SVCV even at the lowest dilution of 10 1 TCID50 mL-1. The ability of RT-LAMP to detect SVCV from infected carp was also tested and the assay detected SVCV from all infected fish. The isothermal temperature requirements, high specificity and sensitivity, and short incubation time of the RT-LAMP assay make it an excellent choice as a field diagnostic test for SVCV. ?? 2008 The Authors.

  1. New methodology to baseline and match AME polysilicon etcher using advanced diagnostic tools

    NASA Astrophysics Data System (ADS)

    Poppe, James; Shipman, John; Reinhardt, Barbara E.; Roussel, Myriam; Hedgecock, Raymond; Fonda, Arturo

    1999-09-01

    As process controls tighten in the semiconductor industry, the need to understand the variables that determine system performance become more important. For plasma etch systems, process success depends on the control of key parameters such as: vacuum integrity, pressure, gas flows, and RF power. It is imperative to baseline, monitor, and control these variables. This paper presents an overview of the methods and tools used by Motorola BMC fabrication facility to characterize an Applied Materials polysilicon etcher. Tool performance data obtained from our traditional measurement techniques are limited in their scope and do not provide a complete picture of the ultimate tool performance. Presently the BMC traditional characterization tools provide a snapshot of the static operation of the equipment under test (EUT); however, complete evaluation of the dynamic performance cannot be monitored without the aid of specialized diagnostic equipment. To provide us with a complete system baseline evaluation of the polysilicon etcher, three diagnostic tools were utilized: Lucas Labs Vacuum Diagnostic System, Residual Gas Analyzer, and the ENI Voltage/Impedance Probe. The diagnostic methodology used to baseline and match key parameters of qualified production equipment has had an immense impact on other equipment characterization in the facility. It has resulted in reduced cycle time for new equipment introduction as well.

  2. Efficient genome-wide association in biobanks using topic modeling identifies multiple novel disease loci.

    PubMed

    McCoy, Thomas H; Castro, Victor M; Snapper, Leslie A; Hart, Kamber L; Perlis, Roy H

    2017-08-31

    Biobanks and national registries represent a powerful tool for genomic discovery, but rely on diagnostic codes that may be unreliable and fail to capture the relationship between related diagnoses. We developed an efficient means of conducting genome-wide association studies using combinations of diagnostic codes from electronic health records (EHR) for 10845 participants in a biobanking program at two large academic medical centers. Specifically, we applied latent Dirichilet allocation to fit 50 disease topics based on diagnostic codes, then conducted genome-wide common-variant association for each topic. In sensitivity analysis, these results were contrasted with those obtained from traditional single-diagnosis phenome-wide association analysis, as well as those in which only a subset of diagnostic codes are included per topic. In meta-analysis across three biobank cohorts, we identified 23 disease-associated loci with p<1e-15, including previously associated autoimmune disease loci. In all cases, observed significant associations were of greater magnitude than for single phenome-wide diagnostic codes, and incorporation of less strongly-loading diagnostic codes enhanced association. This strategy provides a more efficient means of phenome-wide association in biobanks with coded clinical data.

  3. Efficient Genome-wide Association in Biobanks Using Topic Modeling Identifies Multiple Novel Disease Loci

    PubMed Central

    McCoy, Thomas H; Castro, Victor M; Snapper, Leslie A; Hart, Kamber L; Perlis, Roy H

    2017-01-01

    Biobanks and national registries represent a powerful tool for genomic discovery, but rely on diagnostic codes that can be unreliable and fail to capture relationships between related diagnoses. We developed an efficient means of conducting genome-wide association studies using combinations of diagnostic codes from electronic health records for 10,845 participants in a biobanking program at two large academic medical centers. Specifically, we applied latent Dirichilet allocation to fit 50 disease topics based on diagnostic codes, then conducted a genome-wide common-variant association for each topic. In sensitivity analysis, these results were contrasted with those obtained from traditional single-diagnosis phenome-wide association analysis, as well as those in which only a subset of diagnostic codes were included per topic. In meta-analysis across three biobank cohorts, we identified 23 disease-associated loci with p < 1e-15, including previously associated autoimmune disease loci. In all cases, observed significant associations were of greater magnitude than single phenome-wide diagnostic codes, and incorporation of less strongly loading diagnostic codes enhanced association. This strategy provides a more efficient means of identifying phenome-wide associations in biobanks with coded clinical data. PMID:28861588

  4. Rapid Accurate Identification of Tuberculous Meningitis Among South African Children Using a Novel Clinical Decision Tool.

    PubMed

    Goenka, Anu; Jeena, Prakash M; Mlisana, Koleka; Solomon, Tom; Spicer, Kevin; Stephenson, Rebecca; Verma, Arpana; Dhada, Barnesh; Griffiths, Michael J

    2018-03-01

    Early diagnosis of tuberculous meningitis (TBM) is crucial to achieve optimum outcomes. There is no effective rapid diagnostic test for use in children. We aimed to develop a clinical decision tool to facilitate the early diagnosis of childhood TBM. Retrospective case-control study was performed across 7 hospitals in KwaZulu-Natal, South Africa (2010-2014). We identified the variables most predictive of microbiologically confirmed TBM in children (3 months to 15 years) by univariate analysis. These variables were modelled into a clinical decision tool and performance tested on an independent sample group. Of 865 children with suspected TBM, 3% (25) were identified with microbiologically confirmed TBM. Clinical information was retrieved for 22 microbiologically confirmed cases of TBM and compared with 66 controls matched for age, ethnicity, sex and geographical origin. The 9 most predictive variables among the confirmed cases were used to develop a clinical decision tool (CHILD TB LP): altered Consciousness; caregiver HIV infected; Illness length >7 days; Lethargy; focal neurologic Deficit; failure to Thrive; Blood/serum sodium <132 mmol/L; CSF >10 Lymphocytes ×10/L; CSF Protein >0.65 g/L. This tool successfully classified an independent sample of 7 cases and 21 controls with a sensitivity of 100% and specificity of 90%. The CHILD TB LP decision tool accurately classified microbiologically confirmed TBM. We propose that CHILD TB LP is prospectively evaluated as a novel rapid diagnostic tool for use in the initial evaluation of children with suspected neurologic infection presenting to hospitals in similar settings.

  5. Predictive Accuracy of Sweep Frequency Impedance Technology in Identifying Conductive Conditions in Newborns.

    PubMed

    Aithal, Venkatesh; Kei, Joseph; Driscoll, Carlie; Murakoshi, Michio; Wada, Hiroshi

    2018-02-01

    Diagnosing conductive conditions in newborns is challenging for both audiologists and otolaryngologists. Although high-frequency tympanometry (HFT), acoustic stapedial reflex tests, and wideband absorbance measures are useful diagnostic tools, there is performance measure variability in their detection of middle ear conditions. Additional diagnostic sensitivity and specificity measures gained through new technology such as sweep frequency impedance (SFI) measures may assist in the diagnosis of middle ear dysfunction in newborns. The purpose of this study was to determine the test performance of SFI to predict the status of the outer and middle ear in newborns against commonly used reference standards. Automated auditory brainstem response (AABR), HFT (1000 Hz), transient evoked otoacoustic emission (TEOAE), distortion product otoacoustic emission (DPOAE), and SFI tests were administered to the study sample. A total of 188 neonates (98 males and 90 females) with a mean gestational age of 39.4 weeks were included in the sample. Mean age at the time of testing was 44.4 hr. Diagnostic accuracy of SFI was assessed in terms of its ability to identify conductive conditions in neonates when compared with nine different reference standards (including four single tests [AABR, HFT, TEOAE, and DPOAE] and five test batteries [HFT + DPOAE, HFT + TEOAE, DPOAE + TEOAE, DPOAE + AABR, and TEOAE + AABR]), using receiver operating characteristic (ROC) analysis and traditional test performance measures such as sensitivity and specificity. The test performance of SFI against the test battery reference standard of HFT + DPOAE and single reference standard of HFT was high with an area under the ROC curve (AROC) of 0.87 and 0.82, respectively. Although the HFT + DPOAE test battery reference standard performed better than the HFT reference standard in predicting middle ear conductive conditions in neonates, the difference in AROC was not significant. Further analysis revealed that the highest sensitivity and specificity for SFI (86% and 88%, respectively) was obtained when compared with the reference standard of HFT + DPOAE. Among the four single reference standards, SFI had the highest sensitivity and specificity (76% and 88%, respectively) when compared against the HFT reference standard. The high test performance of SFI against the HFT and HFT + DPOAE reference standards indicates that the SFI measure has appropriate diagnostic accuracy in detection of conductive conditions in newborns. Hence, the SFI test could be used as adjunct tool to identify conductive conditions in universal newborn hearing screening programs, and can also be used in diagnostic follow-up assessments. American Academy of Audiology

  6. [Sensitivity and specificity between the Composite International Diagnostic Interview Version 3.0 (World Mental Health, CIDI) and the Standardised Clinical Evaluation version I (SCID-I) in a mental health survey of the city of Medellin, 2012].

    PubMed

    Montoya Gonzalez, Laura Elisa; Restrepo Bernal, Diana Patricia; Mejía-Montoya, Roberto; Bareño-Silva, José; Sierra-Hincapié, Gloria; Torres de Galvis, Yolanda; Marulanda-Restrepo, Daniel; Gómez-Sierra, Natalia; Gaviria-Arbeláez, Silvia

    2016-01-01

    In order to address the mental health problems of the Colombian population it is necessary to have diagnostic tools (local and international) that are valid, easy to apply, and comparable. To compare the sensitivity and specificity between the CIDI 3.0 and the SCID-I for major depressive disorder, bipolar I and II disorder, and substance dependence disorder. Cross-sectional study comparing the life prevalence of three mental disorders in 100 subjects using the CIDI 3.0 and the SCID-I. The study was approved by the Institutional Ethics Committee. The two diagnostic interviews were performed that measured by sensitivity, specificity, positive predictive value and negative predictive value with confidence intervals of 95%. The SPSS version 21.0 software was used for data analysis. The median age was 43.5 years, with an interquartile interval of 30 years. The highest sensitivity (Se) and specificity (Sp) was observed for drug dependence diagnosis - with 80%, (95%CI, 34.94-100), and 98.46 (95%CI, 94.7-100), respectively. SCID-I and CIDI 3.0 showed different levels of sensitivity and specificity for the three disorders studied with: high for substance dependence disorder, moderate for bipolar disorder I and II, and low for major depressive disorder. Copyright © 2015 Asociación Colombiana de Psiquiatría. All rights reserved.

  7. Utility of dengue NS1 antigen rapid diagnostic test for use in difficult to reach areas and its comparison with dengue NS1 ELISA and qRT-PCR.

    PubMed

    Shukla, Mohan K; Singh, Neeru; Sharma, Ravendra K; Barde, Pradip V

    2017-07-01

    The objective of this study was to demonstrate the utility of dengue virus (DENV) non structural protein 1 (NS1) based rapid diagnostic test (RDT) for use in tribal and difficult to reach areas for early dengue (DEN) diagnosis in acute phase patients and evaluate its sensitivity and specificity against DENV NS1 enzyme linked immune sorbent assay (ELISA) and real time reverse transcriptase polymerase chain reaction (qRT-PCR). The DENV NS1 RDT was used for preliminary diagnosis during outbreaks in difficult to reach rural and tribal areas. The diagnosis was confirmed by DENV NS1 ELISA in the laboratory. The samples were also tested and serotyped by qRT-PCR. The results were evaluated using statistical tests. The DENV NS1 RDT showed 99.2% sensitivity and 96.0% specificity when analyzed using DENV NS1 ELISA as standard. The specificity and sensitivity of the RDT when compared with qRT-PCR was 93.6% and 91.1%, respectively. The serotype specific evaluation showed more than 90% sensitivity and specificity for DENV-1, 2, and 3. The RDT proved a good diagnostic tool in difficult to reach rural and tribal areas. Further evaluation studies with different commercially available RDTs in different field conditions are essential, that will help clinicians and patients for treatment and programme managers for timely intervention. © 2017 Wiley Periodicals, Inc.

  8. Potential of mid-infrared spectroscopy as a non-invasive diagnostic test in urine for endometrial or ovarian cancer.

    PubMed

    Paraskevaidi, Maria; Morais, Camilo L M; Lima, Kássio M G; Ashton, Katherine M; Stringfellow, Helen F; Martin-Hirsch, Pierre L; Martin, Francis L

    2018-06-07

    The current lack of an accurate, cost-effective and non-invasive test that would allow for screening and diagnosis of gynaecological carcinomas, such as endometrial and ovarian cancer, signals the necessity for alternative approaches. The potential of spectroscopic techniques in disease investigation and diagnosis has been previously demonstrated. Here, we used attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy to analyse urine samples from women with endometrial (n = 10) and ovarian cancer (n = 10), as well as from healthy individuals (n = 10). After applying multivariate analysis and classification algorithms, biomarkers of disease were pointed out and high levels of accuracy were achieved for both endometrial (95% sensitivity, 100% specificity; accuracy: 95%) and ovarian cancer (100% sensitivity, 96.3% specificity; accuracy 100%). The efficacy of this approach, in combination with the non-invasive method for urine collection, suggest a potential diagnostic tool for endometrial and ovarian cancers.

  9. Improved Diagnostic Accuracy of SPECT Through Statistical Analysis and the Detection of Hot Spots at the Primary Sensorimotor Area for the Diagnosis of Alzheimer Disease in a Community-Based Study: "The Osaki-Tajiri Project".

    PubMed

    Kaneta, Tomohiro; Nakatsuka, Masahiro; Nakamura, Kei; Seki, Takashi; Yamaguchi, Satoshi; Tsuboi, Masahiro; Meguro, Kenichi

    2016-01-01

    SPECT is an important diagnostic tool for dementia. Recently, statistical analysis of SPECT has been commonly used for dementia research. In this study, we evaluated the accuracy of visual SPECT evaluation and/or statistical analysis for the diagnosis (Dx) of Alzheimer disease (AD) and other forms of dementia in our community-based study "The Osaki-Tajiri Project." Eighty-nine consecutive outpatients with dementia were enrolled and underwent brain perfusion SPECT with 99mTc-ECD. Diagnostic accuracy of SPECT was tested using 3 methods: visual inspection (SPECT Dx), automated diagnostic tool using statistical analysis with easy Z-score imaging system (eZIS Dx), and visual inspection plus eZIS (integrated Dx). Integrated Dx showed the highest sensitivity, specificity, and accuracy, whereas eZIS was the second most accurate method. We also observed that a higher than expected rate of SPECT images indicated false-negative cases of AD. Among these, 50% showed hypofrontality and were diagnosed as frontotemporal lobar degeneration. These cases typically showed regional "hot spots" in the primary sensorimotor cortex (ie, a sensorimotor hot spot sign), which we determined were associated with AD rather than frontotemporal lobar degeneration. We concluded that the diagnostic abilities were improved by the integrated use of visual assessment and statistical analysis. In addition, the detection of a sensorimotor hot spot sign was useful to detect AD when hypofrontality is present and improved the ability to properly diagnose AD.

  10. The Generalized Anxiety Disorder Screener (GAD-7) and the anxiety module of the Hospital and Depression Scale (HADS-A) as screening tools for generalized anxiety disorder among cancer patients.

    PubMed

    Esser, Peter; Hartung, Tim J; Friedrich, Michael; Johansen, Christoffer; Wittchen, Hans-Ulrich; Faller, Hermann; Koch, Uwe; Härter, Martin; Keller, Monika; Schulz, Holger; Wegscheider, Karl; Weis, Joachim; Mehnert, Anja

    2018-06-01

    Anxiety in cancer patients may represent a normal psychological reaction. To detect patients with pathological levels, appropriate screeners with established cut-offs are needed. Given that previous research is sparse, we investigated the diagnostic accuracy of 2 frequently used screening tools in detecting generalized anxiety disorder (GAD). We used data of a multicenter study including 2141 cancer patients. Diagnostic accuracy was investigated for the Generalized Anxiety Disorder Screener (GAD-7) and the anxiety module of the Hospital Anxiety and Depression Scale (HADS-A). GAD, assessed with the Composite International Diagnostic Interview for Oncology, served as a reference standard. Overall accuracy was measured with the area under the receiver operating characteristics curve (AUC). The AUC of the 2 screeners were statistically compared. We also calculated accuracy measures for selected cut-offs. Diagnostic accuracy could be interpreted as adequate for both screeners, with an identical AUC of .81 (95% CI: .79-.82). Consequently, the 2 screeners did not differ in their performance (P = .86). The best balance between sensitivity and specificity was found for cut-offs ≥7 (GAD-7) and ≥8 (HADS-A). The officially recommended thresholds for the GAD-7 (≥ 10) and the HADS-A (≥11) showed low sensitivities of 55% and 48%, respectively. The GAD-7 and HADS-A showed AUC of adequate diagnostic accuracy and hence are applicable for GAD screening in cancer patients. Nevertheless, the choice of optimal cut-offs should be carefully evaluated. Copyright © 2018 John Wiley & Sons, Ltd.

  11. Diagnostic accuracy of interleukin-6 and procalcitonin in patients with periprosthetic joint infection: a systematic review and meta-analysis.

    PubMed

    Yoon, Jung-Ro; Yang, Se-Hyun; Shin, Young-Soo

    2018-06-01

    Many studies have found associations between laboratory biomarkers and periprosthetic joint infection (PJI), but it remains unclear whether these biomarkers are clinically useful in ruling out PJI. This meta-analysis compared the performance of interleukin-6 (IL-6) versus procalcitonin (PCT) for the diagnosis of PJI. In this meta-analysis, we reviewed studies that evaluated IL-6 or/and PCT as a diagnostic biomarker for PJI and provided sufficient data to permit sensitivity and specificity analyses for each test. The major databases MEDLINE, EMBASE, the Cochrane Library, Web of Science, and SCOPUS were searched for appropriate studies from the earliest available date of indexing through February 28, 2017. No restrictions were placed on language of publication. We identified 18 studies encompassing a total of 1,835 subjects; 16 studies reported on IL-6 and 6 studies reported on PCT. The area under the curve (AUC) was 0.93 (95% CI, 0.91-0.95) for IL-6 and 0.83 (95% CI, 0.79-0.86) for PCT. The pooled sensitivity was 0.83 (95% CI, 0.74-0.89) for IL-6 and 0.58 (95% CI, 0.31-0.81) for PCT. The pooled specificity was 0.91 (95% CI, 0.84-0.95) for IL-6 and 0.95 (95% CI, 0.63-1.00) for PCT. Both the IL-6 and PCT tests had a high positive likelihood ratio (LR); 9.3 (95% CI, 5.3-16.2) and 12.4 (95% CI, 1.7-89.8), respectively, making them excellent rule-in tests for the diagnosis of PJI. The pooled negative LR for IL-6 was 0.19 (95% CI, 0.12-0.29), making it suitable as a rule-out test, whereas the pooled negative LR for PCT was 0.44 (95% CI, 0.25-0.78), making it unsuitable as a rule-out diagnostic tool. Based on the results of the present meta-analysis, IL-6 has higher diagnostic value than PCT for the diagnosis of PJI. Moreover, the specificity of the IL-6 test is higher than its sensitivity. Conversely, PCT is not recommended for use as a rule-out diagnostic tool.

  12. Accuracy of Pediatric Trauma Field Triage: A Systematic Review.

    PubMed

    van der Sluijs, Rogier; van Rein, Eveline A J; Wijnand, Joep G J; Leenen, Luke P H; van Heijl, Mark

    2018-05-16

    Field triage of pediatric patients with trauma is critical for transporting the right patient to the right hospital. Mortality and lifelong disabilities are potentially attributable to erroneously transporting a patient in need of specialized care to a lower-level trauma center. To quantify the accuracy of field triage and associated diagnostic protocols used to identify children in need of specialized trauma care. MEDLINE, Embase, PsycINFO, and Cochrane Register of Controlled Trials were searched from database inception to November 6, 2017, for studies describing the accuracy of diagnostic tests to identify children in need of specialized trauma care in a prehospital setting. Identified articles with a study population including patients not transported by emergency medical services were excluded. Quality assessment was performed using a modified version of the Quality Assessment of Diagnostic Accuracy Studies-2. After deduplication, 1430 relevant articles were assessed, a full-text review of 38 articles was conducted, and 5 of those articles were included. All studies were observational, published between 1996 and 2017, and conducted in the United States, and data collection was prospective in 1 study. Three different protocols were studied that analyzed a combined total of 1222 children in need of specialized trauma care. One protocol was specifically developed for a pediatric out-of-hospital cohort. The percentage of pediatric patients requiring specialized trauma care in each study varied between 2.6% (110 of 4197) and 54.7% (58 of 106). The sensitivity of the prehospital triage tools ranged from 49.1% to 87.3%, and the specificity ranged from 41.7% to 84.8%. No prehospital triage protocol alone complied with the international standard of 95% or greater sensitivity. Undertriage and overtriage rates, representative of the quality of the full diagnostic strategy to transport a patient to the right hospital, were not reported for inclusive trauma systems or emergency medical services regions. It is crucial to transport the right patient to the right hospital. Yet the quality of the full diagnostic strategy to determine the optimal receiving hospital is unknown. None of the investigated field triage protocols complied with current sensitivity targets. Improved efforts are needed to develop accurate child-specific tools to prevent undertriage and its potential life-threatening consequences.

  13. Differential diagnosis in inflammatory bowel disease colitis: State of the art and future perspectives

    PubMed Central

    Tontini, Gian Eugenio; Vecchi, Maurizio; Pastorelli, Luca; Neurath, Markus F; Neumann, Helmut

    2015-01-01

    Distinction between Crohn’s disease of the colon-rectum and ulcerative colitis or inflammatory bowel disease (IBD) type unclassified can be of pivotal importance for a tailored clinical management, as each entity often involves specific therapeutic strategies and prognosis. Nonetheless, no gold standard is available and the uncertainty of diagnosis may frequently lead to misclassification or repeated examinations. Hence, we have performed a literature search to address the problem of differential diagnosis in IBD colitis, revised current and emerging diagnostic tools and refined disease classification strategies. Nowadays, the differential diagnosis is an untangled issue, and the proper diagnosis cannot be reached in up to 10% of patients presenting with IBD colitis. This topic is receiving emerging attention, as medical therapies, surgical approaches and leading prognostic outcomes require more and more disease-specific strategies in IBD patients. The optimization of standard diagnostic approaches based on clinical features, biomarkers, radiology, endoscopy and histopathology appears to provide only marginal benefits. Conversely, emerging diagnostic techniques in the field of gastrointestinal endoscopy, molecular pathology, genetics, epigenetics, metabolomics and proteomics have already shown promising results. Novel advanced endoscopic imaging techniques and biomarkers can shed new light for the differential diagnosis of IBD, better reflecting diverse disease behaviors based on specific pathogenic pathways. PMID:25574078

  14. Diagnostic value of prostate-specific antigen in women with polycystic ovary syndrome.

    PubMed

    Mardanian, Farahnaz; Heidari, Nasrin

    2011-08-01

    Polycystic ovary syndrome (PCOS) is the most common endocrine disorder in women. Its presentation is that of irregular menstruation associated with ovulation defects. Because of adverse outcomes such as metabolic and cardiovascular disorders, its diagnosis and treatment is very important. Therefore, the diagnostic value of prostatespecific antigen (PSA) in women with polycystic ovary syndrome was evaluated. A total of 32 women with PCOS and 32 aged matched healthy females were recruited in this case-control study. The subjects were compared by means of metabolic measures and serum PSA level. The correlations between these markers were evaluated. Sensitivity and specificity values and cut off levels of PSA were established for diagnosis of PCOS. Mean PSA, Ferriman Gallwey score (FGS), luteinizing hormone/follicle stimulating hormone ratio (LH/FSH), testosterone, dehydroepiandrosterone sulfate (DHEAS), 17(α) hydroxyprogesterone (17(α) HP) levels were significantly higher in PCOS (P<0.001, respectively). PSA levels greater than 0.07 ng/ml yielded a sensitivity of 91% and specificity of 82%, and was helpful as a diagnostic tool for women with PCOS. Circulating androgens and hirsutism were associated with higher levels of PSA in PCOS women. Our results showed direct correlation between PSA, hirsutism and hyperandrogemsm state. Therefore, it seems logical to use PSA level for detection of hyperandrogemsm state in women.

  15. A Meta-analysis for the Diagnostic Performance of Transient Elastography for Clinically Significant Portal Hypertension.

    PubMed

    You, Myung-Won; Kim, Kyung Won; Pyo, Junhee; Huh, Jimi; Kim, Hyoung Jung; Lee, So Jung; Park, Seong Ho

    2017-01-01

    We aimed to evaluate the correlation between liver stiffness measurement using transient elastography (TE-LSM) and hepatic venous pressure gradient and the diagnostic performance of TE-LSM in assessing clinically significant portal hypertension through meta-analysis. Eleven studies were included from thorough literature research and selection processes. The summary correlation coefficient was 0.783 (95% confidence interval [CI], 0.737-0.823). Summary sensitivity, specificity and area under the hierarchical summary receiver operating characteristic curve (AUC) were 87.5% (95% CI, 75.8-93.9%), 85.3 % (95% CI, 76.9-90.9%) and 0.9, respectively. The subgroup with low cut-off values of 13.6-18 kPa had better summary estimates (sensitivity 91.2%, specificity 81.3% and partial AUC 0.921) than the subgroup with high cut-off values of 21-25 kPa (sensitivity 71.2%, specificity 90.9% and partial AUC 0.769). In summary, TE-LSM correlated well with hepatic venous pressure gradient and represented good diagnostic performance in diagnosing clinically significant portal hypertension. For use as a sensitive screening tool, we propose using low cut-off values of 13.6-18 kPa in TE-LSM. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  16. Super-Resolution Microscopy of Cerebrospinal Fluid Biomarkers as a Tool for Alzheimer's Disease Diagnostics.

    PubMed

    Zhang, William I; Antonios, Gregory; Rabano, Alberto; Bayer, Thomas A; Schneider, Anja; Rizzoli, Silvio O

    2015-01-01

    Alzheimer's disease (AD) is neuropathologically characterized by aggregates of amyloid-β peptides (Aβ) and tau proteins. The consensus in the AD field is that Aβ and tau should serve as diagnostic biomarkers for AD. However, their aggregates have been difficult to investigate by conventional fluorescence microscopy, since their size is below the diffraction limit (∼200 nm). To solve this, we turned to a super-resolution imaging technique, stimulated emission depletion (STED) microscopy, which has a high enough precision to allow the discrimination of low- and high-molecular weight aggregates prepared in vitro. We used STED to analyze the structural organization of Aβ and tau in cerebrospinal fluid (CSF) from 36 AD patients, 11 patients with mild cognitive impairment (MCI), and 21 controls. We measured the numbers of aggregates in the CSF samples, and the aggregate sizes and intensities. These parameters enabled us to distinguish AD patients from controls with a specificity of ∼87% and a sensitivity of ∼79% . In addition, the aggregate parameters determined with STED microscopy correlated with the severity of cognitive impairment in AD patients. Finally, these parameters may be useful as predictive tools for MCI cases. The STED parameters of two MCI patients who developed AD during the course of the study, as well as of MCI patients whose Aβ ELISA values fall within the accepted range for AD, placed them close to the AD averages. We suggest that super-resolution imaging is a promising tool for AD diagnostics.

  17. Chronic Pelvic Pain: Assessment, Evaluation, and Objectivation

    PubMed Central

    Pota, Vincenzo; Sansone, Pasquale; Aurilio, Caterina; Pace, Maria Caterina

    2017-01-01

    Chronic Pelvic Pain (CPP) and Chronic Pelvic Pain Syndrome (CPPS) have a significant impact on men and women of reproductive and nonreproductive age, with a considerable burden on overall quality of life (QoL) and on psychological, functional, and behavioural status. Moreover, diagnostic and therapeutic difficulties are remarkable features in many patients. Therefore evaluation, assessment and objectivation tools are often necessary to properly address each patient and consequently his/her clinical needs. Here we review the different tools for pain assessment, evaluation, and objectivation; specific features regarding CPP/CPPS will be highlighted. Also, recent findings disclosed with neuroimaging investigations will be reviewed as they provide new insights into CPP/CPPS pathophysiology and may serve as a tool for CPP assessment and objectivation. PMID:29359045

  18. Nanotechnology applications in hematological malignancies (Review).

    PubMed

    Samir, Ahmed; Elgamal, Basma M; Gabr, Hala; Sabaawy, Hatem E

    2015-09-01

    A major limitation to current cancer therapies is the development of therapy-related side-effects and dose limiting complications. Moreover, a better understanding of the biology of cancer cells and the mechanisms of resistance to therapy is rapidly developing. The translation of advanced knowledge and discoveries achieved at the molecular level must be supported by advanced diagnostic, therapeutic and delivery technologies to translate these discoveries into useful tools that are essential in achieving progress in the war against cancer. Nanotechnology can play an essential role in this aspect providing a transforming technology that can translate the basic and clinical findings into novel diagnostic, therapeutic and preventive tools useful in different types of cancer. Hematological malignancies represent a specific class of cancer, which attracts special attention in the applications of nanotechnology for cancer diagnosis and treatment. The aim of the present review is to elucidate the emerging applications of nanotechnology in cancer management and describe the potentials of nanotechnology in changing the key fundamental aspects of hematological malignancy diagnosis, treatment and follow-up.

  19. Bone Disease after Kidney Transplantation

    PubMed Central

    Bouquegneau, Antoine; Salam, Syrazah; Delanaye, Pierre; Eastell, Richard

    2016-01-01

    Bone and mineral disorders occur frequently in kidney transplant recipients and are associated with a high risk of fracture, morbidity, and mortality. There is a broad spectrum of often overlapping bone diseases seen after transplantation, including osteoporosis as well as persisting high– or low–turnover bone disease. The pathophysiology underlying bone disorders after transplantation results from a complex interplay of factors, including preexisting renal osteodystrophy and bone loss related to a variety of causes, such as immunosuppression and alterations in the parathyroid hormone-vitamin D-fibroblast growth factor 23 axis as well as changes in mineral metabolism. Management is complex, because noninvasive tools, such as imaging and bone biomarkers, do not have sufficient sensitivity and specificity to detect these abnormalities in bone structure and function, whereas bone biopsy is not a widely available diagnostic tool. In this review, we focus on recent data that highlight improvements in our understanding of the prevalence, pathophysiology, and diagnostic and therapeutic strategies of mineral and bone disorders in kidney transplant recipients. PMID:26912549

  20. The construction and application of a cell line resistant to novel subgroup avian leukosis virus (ALV-K) infection.

    PubMed

    Mingzhang, Rao; Zijun, Zhao; Lixia, Yuan; Jian, Chen; Min, Feng; Jie, Zhang; Ming, Liao; Weisheng, Cao

    2018-01-01

    A novel avian leukosis viruses (ALV) subgroup named ALV-K was recently isolated from Chinese indigenous chickens which is different from the subgroups (A to E and J) that have previously been reported to infect chickens. More and more ALV-K strains have recently been isolated from local breeds of Chinese chickens. However, there are no more effective diagnostic methods for ALV-K other than virus isolation followed by envelope gene sequencing and comparison. Viral infection can be blocked through expression of the viral receptor-binding protein. In this study, we have engineered a cell line, DF-1/K, that expresses ALV-K env protein and thereby confers resistance to ALV-K infection. DF-1/K can be used in combination with the ALV-K susceptible cell line DF-1 as a specific diagnostic tool for ALV-K and provides a good tool for further research into the molecular mechanisms of interaction between ALV-K env protein and the host cell receptor.

  1. Nanotechnology applications in hematological malignancies (Review)

    PubMed Central

    SAMIR, AHMED; ELGAMAL, BASMA M; GABR, HALA; SABAAWY, HATEM E

    2015-01-01

    A major limitation to current cancer therapies is the development of therapy-related side-effects and dose limiting complications. Moreover, a better understanding of the biology of cancer cells and the mechanisms of resistance to therapy is rapidly developing. The translation of advanced knowledge and discoveries achieved at the molecular level must be supported by advanced diagnostic, therapeutic and delivery technologies to translate these discoveries into useful tools that are essential in achieving progress in the war against cancer. Nanotechnology can play an essential role in this aspect providing a transforming technology that can translate the basic and clinical findings into novel diagnostic, therapeutic and preventive tools useful in different types of cancer. Hematological malignancies represent a specific class of cancer, which attracts special attention in the applications of nanotechnology for cancer diagnosis and treatment. The aim of the present review is to elucidate the emerging applications of nanotechnology in cancer management and describe the potentials of nanotechnology in changing the key fundamental aspects of hematological malignancy diagnosis, treatment and follow-up. PMID:26134389

  2. [Ischemic origin of diabetic foot disease. Epidemiology, difficulties of diagnosis, options for prevention and revascularization].

    PubMed

    Kolossváry, Endre; Bánsághi, Zoltán; Szabó, Gábor Viktor; Járai, Zoltán; Farkas, Katalin

    2017-02-01

    "Diabetic foot" as definition covers a multifactorial clinical condition. According to the recent epidemiological data, the role of lower limb ischemia is getting more influential over other pathological causes, like neuropathy, infections and bone or soft tissue deformity. In diabetes, vascular disease leads to increased risk for leg ulcers and minor or major amputations. The traditional diagnostic tools for recognition of peripheral arterial disease have limited value because of diabetes specific clinical manifestations. Available vascular centers with special expertise and diagnostic tools are the prerequisite for efficient diagnosis supporting timely recognition of peripheral arterial disease. In course of treatment of diabetic foot with ischemic origin, beyond effective medical treatment revascularization (open vascular surgery or endovascular procedures) has paramount importance for prevention of limb loss. Vascular teams of vascular specialists, vascular surgeons and interventional radiologist in dedicated centers in multidisciplinary cooperation with other professions represent public health issue in effective prevention. Orv. Hetil., 2017, 158(6), 203-211.

  3. The Role of microRNA Markers in the Diagnosis, Treatment, and Outcome Prediction of Spinal Cord Injury.

    PubMed

    Martirosyan, Nikolay L; Carotenuto, Alessandro; Patel, Arpan A; Kalani, M Yashar S; Yagmurlu, Kaan; Lemole, G Michael; Preul, Mark C; Theodore, Nicholas

    2016-01-01

    Spinal cord injury (SCI) is a devastating condition that affects many people worldwide. Treatment focuses on controlling secondary injury cascade and improving regeneration. It has recently been suggested that both the secondary injury cascade and the regenerative process are heavily regulated by microRNAs (miRNAs). The measurement of specific biomarkers could improve our understanding of the disease processes, and thereby provide clinicians with the opportunity to guide treatment and predict clinical outcomes after SCI. A variety of miRNAs exhibit important roles in processes of inflammation, cell death, and regeneration. These miRNAs can be used as diagnostic tools for predicting outcome after SCI. In addition, miRNAs can be used in the treatment of SCI and its symptoms. Significant laboratory and clinical evidence exist to show that miRNAs could be used as robust diagnostic and therapeutic tools for the treatment of patients with SCI. Further clinical studies are warranted to clarify the importance of each subtype of miRNA in SCI management.

  4. Diagnostic value of 3D time-of-flight MRA in trigeminal neuralgia.

    PubMed

    Cai, Jing; Xin, Zhen-Xue; Zhang, Yu-Qiang; Sun, Jie; Lu, Ji-Liang; Xie, Feng

    2015-08-01

    The aim of this meta-analysis was to evaluate the diagnostic value of 3D time-of-flight magnetic resonance angiography (3D-TOF-MRA) in trigeminal neuralgia (TN). Relevant studies were identified by computerized database searches supplemented by manual search strategies. The studies were included in accordance with stringent inclusion and exclusion criteria. Following a multistep screening process, high quality studies related to the diagnostic value of 3D-TOF-MRA in TN were selected for meta-analysis. Statistical analyses were conducted using Statistical Analysis Software (version 8.2; SAS Institute, Cary, NC, USA) and Meta Disc (version 1.4; Unit of Clinical Biostatistics, Ramon y Cajal Hospital, Madrid, Spain). For the present meta-analysis, we initially retrieved 95 studies from database searches. A total of 13 studies were eventually enrolled containing a combined total of 1084 TN patients. The meta-analysis results demonstrated that the sensitivity and specificity of the diagnostic value of 3D-TOF-MRA in TN were 95% (95% confidence interval [CI] 0.93-0.96) and 77% (95% CI 0.66-0.86), respectively. The pooled positive likelihood ratio and negative likelihood ratio were 2.72 (95% CI 1.81-4.09) and 0.08 (95% CI 0.06-0.12), respectively. The pooled diagnostic odds ratio of 3D-TOF-MRA in TN was 52.92 (95% CI 26.39-106.11), and the corresponding area under the curve in the summary receiver operating characteristic curve based on the 3D-TOF-MRA diagnostic image of observers was 0.9695 (standard error 0.0165). Our results suggest that 3D-TOF-MRA has excellent sensitivity and specificity as a diagnostic tool for TN, and that it can accurately identify neurovascular compression in TN patients. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Diagnostic Performance of Narrow Band Imaging for Laryngeal Cancer: A Systematic Review and Meta-analysis.

    PubMed

    Sun, Changling; Han, Xue; Li, Xiaoying; Zhang, Yayun; Du, Xiaodong

    2017-04-01

    Objective To evaluate the performance of narrow band imaging (NBI) for the diagnosis of laryngeal cancer and to compare the diagnostic value of NBI with that of white light endoscopy. Data Sources PubMed, Embase, Cochrane Library, and CNKI databases. Review Methods Data analyses were performed with Meta-DiSc. The updated Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to assess study quality and potential bias. Publication bias was assessed with the Deeks's asymmetry test. The protocol used in this article has been published on PROSPERO and is in accordance with the PRISMA checklist. The registry number for this study is CRD42015025866. Results Six studies including 716 lesions were included in this meta-analysis. The pooled sensitivity, specificity, and diagnostic odds ratio for the NBI diagnosis of laryngeal cancer were 0.94 (95% confidence interval [95% CI]: 0.91-0.96), 0.89 (95% CI: 0.85-0.92), and 142.12 (95% CI: 46.42-435.15), respectively, and the area under receiver operating characteristics curve was 0.97. Among the 6 studies, 3 evaluated the diagnostic value of white light endoscopy, with a sensitivity of 0.81 (95% CI: 0.76-0.86), a specificity of 0.92 (95% CI: 0.88-0.95), and a diagnostic odds ratio of 33.82 (95% CI: 14.76-77.49). The evaluation of heterogeneity, calculated per the diagnostic odds ratio, gave an I 2 of 66%. No marked publication bias ( P = .84) was detected in this meta-analysis. Conclusion The sensitivity of NBI is superior to white light endoscopy, and the potential value of NBI needs to be validated in future studies.

  6. The Montreal Protocol for Identification of Amusia.

    PubMed

    Vuvan, D T; Paquette, S; Mignault Goulet, G; Royal, I; Felezeu, M; Peretz, I

    2018-04-01

    The Montreal Battery for the Evaluation of Amusia (MBEA; Peretz, Champod, & Hyde Annals of the New York Academy of Sciences, 999, 58-75, 2003) is an empirically grounded quantitative tool that is widely used to identify individuals with congenital amusia. The use of such a standardized measure ensures that the individuals tested will conform to a specific neuropsychological profile, allowing for comparisons across studies and research groups. Recently, a number of researchers have published credible critiques of the usefulness of the MBEA as a diagnostic tool for amusia. Here we argue that the MBEA and its online counterpart, the AMUSIA tests (Peretz et al. Music Perception, 25, 331-343, 2008), should be considered steps in a screening process for amusia, rather than standalone diagnostic tools. The goal of this article is to present, in detailed and easily replicable format, the full protocol through which congenital amusics should be identified. In providing information that has often gone unreported in published articles, we aim to clarify the strengths and limitations of the MBEA and to make recommendations for its continued use by the research community as part of the Montreal Protocol for Identification of Amusia.

  7. The Validity of the Montgomery-Asberg Depression Rating Scale in an Inpatient Sample with Alcohol Dependence

    PubMed Central

    Hobden, Breanne; Schwandt, Melanie L.; Carey, Mariko; Lee, Mary R.; Farokhnia, Mehdi; Bouhlal, Sofia; Oldmeadow, Christopher; Leggio, Lorenzo

    2017-01-01

    Background The Montgomery-Asberg Depression Rating Scale (MADRS) is commonly used to examine depressive symptoms in clinical settings, including facilities treating patients for alcohol addiction. No studies have examined the validity of the MADRS compared to an established clinical diagnostic tool of depression in this population. This study aimed to examine: 1) the validity of the MADRS compared to a clinical diagnosis of a depressive disorder (using the Structured Clinical Interview for DSM-IV (SCID)) in patients seeking treatment for alcohol dependence (AD); 2) whether the validity of the MADRS differs by type of SCID-based diagnosis of depression; and 3) which items contribute to the optimal predictive model of the MADRS compared to a SCID diagnosis of a depressive disorder. Methods Individuals seeking treatment for AD and admitted to an inpatient unit were administered the MADRS at day 2 of their detoxification program. Clinical diagnoses of AD and depression were made via the Structured Clinical Interview for the Diagnostic and Statistical Manual of Mental Disorders-IV at the beginning of treatment. Results In total, 803 participants were included in the study. The MADRS demonstrated low overall accuracy relative to the clinical diagnosis of depression with an area under the curve of 0.68. The optimal threshold for balancing sensitivity and specificity identified by the Euclidean distance was >14. This cut-point demonstrated a sensitivity of 66%, a specificity of 60%, a positive predictive value of 50% and a negative predictive value of 75%. The MADRS performed slightly better for major depressive disorders compared to alcohol-induced depression. Items related to lassitude, concentration and appetite slightly decreased the accuracy of the MADRS. Conclusion The MADRS does not appear to be an appropriate substitute for a diagnostic tool among alcohol-dependent patients. The MADRS may, however, still be a useful screening tool assuming careful consideration of cut-off scores. PMID:28421616

  8. A comparison of bivariate, multivariate random-effects, and Poisson correlated gamma-frailty models to meta-analyze individual patient data of ordinal scale diagnostic tests.

    PubMed

    Simoneau, Gabrielle; Levis, Brooke; Cuijpers, Pim; Ioannidis, John P A; Patten, Scott B; Shrier, Ian; Bombardier, Charles H; de Lima Osório, Flavia; Fann, Jesse R; Gjerdingen, Dwenda; Lamers, Femke; Lotrakul, Manote; Löwe, Bernd; Shaaban, Juwita; Stafford, Lesley; van Weert, Henk C P M; Whooley, Mary A; Wittkampf, Karin A; Yeung, Albert S; Thombs, Brett D; Benedetti, Andrea

    2017-11-01

    Individual patient data (IPD) meta-analyses are increasingly common in the literature. In the context of estimating the diagnostic accuracy of ordinal or semi-continuous scale tests, sensitivity and specificity are often reported for a given threshold or a small set of thresholds, and a meta-analysis is conducted via a bivariate approach to account for their correlation. When IPD are available, sensitivity and specificity can be pooled for every possible threshold. Our objective was to compare the bivariate approach, which can be applied separately at every threshold, to two multivariate methods: the ordinal multivariate random-effects model and the Poisson correlated gamma-frailty model. Our comparison was empirical, using IPD from 13 studies that evaluated the diagnostic accuracy of the 9-item Patient Health Questionnaire depression screening tool, and included simulations. The empirical comparison showed that the implementation of the two multivariate methods is more laborious in terms of computational time and sensitivity to user-supplied values compared to the bivariate approach. Simulations showed that ignoring the within-study correlation of sensitivity and specificity across thresholds did not worsen inferences with the bivariate approach compared to the Poisson model. The ordinal approach was not suitable for simulations because the model was highly sensitive to user-supplied starting values. We tentatively recommend the bivariate approach rather than more complex multivariate methods for IPD diagnostic accuracy meta-analyses of ordinal scale tests, although the limited type of diagnostic data considered in the simulation study restricts the generalization of our findings. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Urinary Proteomic Biomarkers for Diagnosis and Risk Stratification of Autosomal Dominant Polycystic Kidney Disease: A Multicentric Study

    PubMed Central

    Kistler, Andreas D.; Serra, Andreas L.; Siwy, Justyna; Poster, Diane; Krauer, Fabienne; Torres, Vicente E.; Mrug, Michal; Grantham, Jared J.; Bae, Kyongtae T.; Bost, James E.; Mullen, William; Wüthrich, Rudolf P.; Mischak, Harald; Chapman, Arlene B.

    2013-01-01

    Treatment options for autosomal dominant polycystic kidney disease (ADPKD) will likely become available in the near future, hence reliable diagnostic and prognostic biomarkers for the disease are strongly needed. Here, we aimed to define urinary proteomic patterns in ADPKD patients, which aid diagnosis and risk stratification. By capillary electrophoresis online coupled to mass spectrometry (CE-MS), we compared the urinary peptidome of 41 ADPKD patients to 189 healthy controls and identified 657 peptides with significantly altered excretion, of which 209 could be sequenced using tandem mass spectrometry. A support-vector-machine based diagnostic biomarker model based on the 142 most consistent peptide markers achieved a diagnostic sensitivity of 84.5% and specificity of 94.2% in an independent validation cohort, consisting of 251 ADPKD patients from five different centers and 86 healthy controls. The proteomic alterations in ADPKD included, but were not limited to markers previously associated with acute kidney injury (AKI). The diagnostic biomarker model was highly specific for ADPKD when tested in a cohort consisting of 481 patients with a variety of renal and extrarenal diseases, including AKI. Similar to ultrasound, sensitivity and specificity of the diagnostic score depended on patient age and genotype. We were furthermore able to identify biomarkers for disease severity and progression. A proteomic severity score was developed to predict height adjusted total kidney volume (htTKV) based on proteomic analysis of 134 ADPKD patients and showed a correlation of r = 0.415 (p<0.0001) with htTKV in an independent validation cohort consisting of 158 ADPKD patients. In conclusion, the performance of peptidomic biomarker scores is superior to any other biochemical markers of ADPKD and the proteomic biomarker patterns are a promising tool for prognostic evaluation of ADPKD. PMID:23326375

  10. Ultrasound for Distal Forearm Fracture: A Systematic Review and Diagnostic Meta-Analysis

    PubMed Central

    Douma-den Hamer, Djoke; Blanker, Marco H.; Edens, Mireille A.; Buijteweg, Lonneke N.; Boomsma, Martijn F.; van Helden, Sven H.; Mauritz, Gert-Jan

    2016-01-01

    Study Objective To determine the diagnostic accuracy of ultrasound for detecting distal forearm fractures. Methods A systematic review and diagnostic meta-analysis was performed according to the PRISMA statement. We searched MEDLINE, Web of Science and the Cochrane Library from inception to September 2015. All prospective studies of the diagnostic accuracy of ultrasound versus radiography as the reference standard were included. We excluded studies with a retrospective design and those with evidence of verification bias. We assessed the methodological quality of the included studies with the QUADAS-2 tool. We performed a meta-analysis of studies evaluating ultrasound to calculate the pooled sensitivity and specificity with 95% confidence intervals (CI95%) using a bivariate model with random effects. Subgroup and sensitivity analysis were used to examine the effect of methodological differences and other study characteristics. Results Out of 867 publications we included 16 studies with 1,204 patients and 641 fractures. The pooled test characteristics for ultrasound were: sensitivity 97% (CI95% 93–99%), specificity 95% (CI95% 89–98%), positive likelihood ratio (LR) 20.0 (8.5–47.2) and negative LR 0.03 (0.01–0.08). The corresponding pooled diagnostic odds ratio (DOR) was 667 (142–3,133). Apparent differences were shown for method of viewing, with the 6-view method showing higher specificity, positive LR, and DOR, compared to the 4-view method. Conclusion The present meta-analysis showed that ultrasound has a high accuracy for the diagnosis of distal forearm fractures in children when used by proper viewing method. Based on this, ultrasound should be considered a reliable alternative, which has the advantages of being radiation free. PMID:27196439

  11. Genetic Determinants of Drug Resistance in Mycobacterium tuberculosis and Their Diagnostic Value.

    PubMed

    Farhat, Maha R; Sultana, Razvan; Iartchouk, Oleg; Bozeman, Sam; Galagan, James; Sisk, Peter; Stolte, Christian; Nebenzahl-Guimaraes, Hanna; Jacobson, Karen; Sloutsky, Alexander; Kaur, Devinder; Posey, James; Kreiswirth, Barry N; Kurepina, Natalia; Rigouts, Leen; Streicher, Elizabeth M; Victor, Tommie C; Warren, Robin M; van Soolingen, Dick; Murray, Megan

    2016-09-01

    The development of molecular diagnostics that detect both the presence of Mycobacterium tuberculosis in clinical samples and drug resistance-conferring mutations promises to revolutionize patient care and interrupt transmission by ensuring early diagnosis. However, these tools require the identification of genetic determinants of resistance to the full range of antituberculosis drugs. To determine the optimal molecular approach needed, we sought to create a comprehensive catalog of resistance mutations and assess their sensitivity and specificity in diagnosing drug resistance. We developed and validated molecular inversion probes for DNA capture and deep sequencing of 28 drug-resistance loci in M. tuberculosis. We used the probes for targeted sequencing of a geographically diverse set of 1,397 clinical M. tuberculosis isolates with known drug resistance phenotypes. We identified a minimal set of mutations to predict resistance to first- and second-line antituberculosis drugs and validated our predictions in an independent dataset. We constructed and piloted a web-based database that provides public access to the sequence data and prediction tool. The predicted resistance to rifampicin and isoniazid exceeded 90% sensitivity and specificity but was lower for other drugs. The number of mutations needed to diagnose resistance is large, and for the 13 drugs studied it was 238 across 18 genetic loci. These data suggest that a comprehensive M. tuberculosis drug resistance diagnostic will need to allow for a high dimension of mutation detection. They also support the hypothesis that currently unknown genetic determinants, potentially discoverable by whole-genome sequencing, encode resistance to second-line tuberculosis drugs.

  12. Genetic Determinants of Drug Resistance in Mycobacterium tuberculosis and Their Diagnostic Value

    PubMed Central

    Sultana, Razvan; Iartchouk, Oleg; Bozeman, Sam; Galagan, James; Sisk, Peter; Stolte, Christian; Nebenzahl-Guimaraes, Hanna; Jacobson, Karen; Sloutsky, Alexander; Kaur, Devinder; Posey, James; Kreiswirth, Barry N.; Kurepina, Natalia; Rigouts, Leen; Streicher, Elizabeth M.; Victor, Tommie C.; Warren, Robin M.; van Soolingen, Dick; Murray, Megan

    2016-01-01

    Rationale: The development of molecular diagnostics that detect both the presence of Mycobacterium tuberculosis in clinical samples and drug resistance–conferring mutations promises to revolutionize patient care and interrupt transmission by ensuring early diagnosis. However, these tools require the identification of genetic determinants of resistance to the full range of antituberculosis drugs. Objectives: To determine the optimal molecular approach needed, we sought to create a comprehensive catalog of resistance mutations and assess their sensitivity and specificity in diagnosing drug resistance. Methods: We developed and validated molecular inversion probes for DNA capture and deep sequencing of 28 drug-resistance loci in M. tuberculosis. We used the probes for targeted sequencing of a geographically diverse set of 1,397 clinical M. tuberculosis isolates with known drug resistance phenotypes. We identified a minimal set of mutations to predict resistance to first- and second-line antituberculosis drugs and validated our predictions in an independent dataset. We constructed and piloted a web-based database that provides public access to the sequence data and prediction tool. Measurements and Main Results: The predicted resistance to rifampicin and isoniazid exceeded 90% sensitivity and specificity but was lower for other drugs. The number of mutations needed to diagnose resistance is large, and for the 13 drugs studied it was 238 across 18 genetic loci. Conclusions: These data suggest that a comprehensive M. tuberculosis drug resistance diagnostic will need to allow for a high dimension of mutation detection. They also support the hypothesis that currently unknown genetic determinants, potentially discoverable by whole-genome sequencing, encode resistance to second-line tuberculosis drugs. PMID:26910495

  13. Dehydrin expression as a potential diagnostic tool for cold stress in white clover.

    PubMed

    Vaseva, Irina Ivanova; Anders, Iwona; Yuperlieva-Mateeva, Bistra; Nenkova, Rosa; Kostadinova, Anelia; Feller, Urs

    2014-05-01

    Cold acclimation is important for crop survival in environments undergoing seasonal low temperatures. It involves the induction of defensive mechanisms including the accumulation of different cryoprotective molecules among which are dehydrins (DHN). Recently several sequences coding for dehydrins were identified in white clover (Trifolium repens). This work aimed to select the most responsive to cold stress DHN analogues in search for cold stress diagnostic markers. The assessment of dehydrin transcript accumulation via RT-PCR and immunodetection performed with three antibodies against the conserved K-, Y-, and S-segment allowed to outline different dehydrin types presented in the tested samples. Both analyses confirmed that YnKn dehydrins were underrepresented in the controls but exposure to low temperature specifically induced their accumulation. Strong immunosignals corresponding to 37-40 kDa with antibodies against Y- and K-segment were revealed in cold-stressed leaves. Another 'cold-specific' band at position 52-55 kDa was documented on membranes probed with antibodies against K-segment. Real time RT-qPCR confirmed that low temperatures induced the accumulation of SKn and YnSKn transcripts in leaves and reduced their expression in roots. Results suggest that a YnKn dehydrin transcript with GenBank ID: KC247805 and the immunosignal at 37-40 kDa, obtained with antibodies against Y- and K-segment are reliable markers for cold stress in white clover. The assessment of SKn (GenBank ID: EU846208) and YnSKn (GenBank ID: KC247804) transcript levels in leaves could serve as additional diagnostic tools. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  14. Accuracy of clinical diagnosis versus the World Health Organization case definition in the Amoy Garden SARS cohort.

    PubMed

    Wong, W N; Sek, Antonio C H; Lau, Rick F L; Li, K M; Leung, Joe K S; Tse, M L; Ng, Andy H W; Stenstrom, Robert

    2003-11-01

    To compare the diagnostic accuracy of emergency department (ED) physicians with the World Health Organization (WHO) case definition in a large community-based SARS (severe acute respiratory syndrome) cohort. This was a cohort study of all patients from Hong Kong's Amoy Garden complex who presented to an ED SARS screening clinic during a 2-month outbreak. Clinical findings and WHO case definition criteria were recorded, along with ED diagnoses. Final diagnoses were established independently based on relevant diagnostic tests performed after the ED visit. Emergency physician diagnostic accuracy was compared with that of the WHO SARS case definition. Sensitivity, specificity, predictive values and likelihood ratios were calculated using standard formulae. During the study period, 818 patients presented with SARS-like symptoms, including 205 confirmed SARS, 35 undetermined SARS and 578 non-SARS. Sensitivity, specificity and accuracy were 91%, 96% and 94% for ED clinical diagnosis, versus 42%, 86% and 75% for the WHO case definition. Positive likelihood ratios (LR+) were 21.1 for physician judgement and 3.1 for the WHO criteria. Negative likelihood ratios (LR-) were 0.10 for physician judgement and 0.67 for the WHO criteria, indicating that clinician judgement was a much more powerful predictor than the WHO criteria. Physician clinical judgement was more accurate than the WHO case definition. Reliance on the WHO case definition as a SARS screening tool may lead to an unacceptable rate of misdiagnosis. The SARS case definition must be revised if it is to be used as a screening tool in emergency departments and primary care settings.

  15. Evidence assessing the diagnostic performance of medical smartphone apps: a systematic review and exploratory meta-analysis

    PubMed Central

    Buechi, Rahel; Faes, Livia; Bachmann, Lucas M; Thiel, Michael A; Bodmer, Nicolas S; Schmid, Martin K; Job, Oliver; Lienhard, Kenny R

    2017-01-01

    Objective The number of mobile applications addressing health topics is increasing. Whether these apps underwent scientific evaluation is unclear. We comprehensively assessed papers investigating the diagnostic value of available diagnostic health applications using inbuilt smartphone sensors. Methods Systematic Review—MEDLINE, Scopus, Web of Science inclusive Medical Informatics and Business Source Premier (by citation of reference) were searched from inception until 15 December 2016. Checking of reference lists of review articles and of included articles complemented electronic searches. We included all studies investigating a health application that used inbuilt sensors of a smartphone for diagnosis of disease. The methodological quality of 11 studies used in an exploratory meta-analysis was assessed with the Quality Assessment of Diagnostic Accuracy Studies 2 tool and the reporting quality with the ’STAndards for the Reporting of Diagnostic accuracy studies' (STARD) statement. Sensitivity and specificity of studies reporting two-by-two tables were calculated and summarised. Results We screened 3296 references for eligibility. Eleven studies, most of them assessing melanoma screening apps, reported 17 two-by-two tables. Quality assessment revealed high risk of bias in all studies. Included papers studied 1048 subjects (758 with the target conditions and 290 healthy volunteers). Overall, the summary estimate for sensitivity was 0.82 (95 % CI 0.56 to 0.94) and 0.89 (95 %CI 0.70 to 0.97) for specificity. Conclusions The diagnostic evidence of available health apps on Apple’s and Google’s app stores is scarce. Consumers and healthcare professionals should be aware of this when using or recommending them. PROSPERO registration number 42016033049. PMID:29247099

  16. Community-based benchmarking of the CMIP DECK experiments

    NASA Astrophysics Data System (ADS)

    Gleckler, P. J.

    2015-12-01

    A diversity of community-based efforts are independently developing "diagnostic packages" with little or no coordination between them. A short list of examples include NCAR's Climate Variability Diagnostics Package (CVDP), ORNL's International Land Model Benchmarking (ILAMB), LBNL's Toolkit for Extreme Climate Analysis (TECA), PCMDI's Metrics Package (PMP), the EU EMBRACE ESMValTool, the WGNE MJO diagnostics package, and CFMIP diagnostics. The full value of these efforts cannot be realized without some coordination. As a first step, a WCRP effort has initiated a catalog to document candidate packages that could potentially be applied in a "repeat-use" fashion to all simulations contributed to the CMIP DECK (Diagnostic, Evaluation and Characterization of Klima) experiments. Some coordination of community-based diagnostics has the additional potential to improve how CMIP modeling groups analyze their simulations during model-development. The fact that most modeling groups now maintain a "CMIP compliant" data stream means that in principal without much effort they could readily adopt a set of well organized diagnostic capabilities specifically designed to operate on CMIP DECK experiments. Ultimately, a detailed listing of and access to analysis codes that are demonstrated to work "out of the box" with CMIP data could enable model developers (and others) to select those codes they wish to implement in-house, potentially enabling more systematic evaluation during the model development process.

  17. Evolution of Quality Assurance for Clinical Immunohistochemistry in the Era of Precision Medicine: Part 4: Tissue Tools for Quality Assurance in Immunohistochemistry.

    PubMed

    Cheung, Carol C; D'Arrigo, Corrado; Dietel, Manfred; Francis, Glenn D; Fulton, Regan; Gilks, C Blake; Hall, Jacqueline A; Hornick, Jason L; Ibrahim, Merdol; Marchetti, Antonio; Miller, Keith; van Krieken, J Han; Nielsen, Soren; Swanson, Paul E; Taylor, Clive R; Vyberg, Mogens; Zhou, Xiaoge; Torlakovic, Emina E

    2017-04-01

    The numbers of diagnostic, prognostic, and predictive immunohistochemistry (IHC) tests are increasing; the implementation and validation of new IHC tests, revalidation of existing tests, as well as the on-going need for daily quality assurance monitoring present significant challenges to clinical laboratories. There is a need for proper quality tools, specifically tissue tools that will enable laboratories to successfully carry out these processes. This paper clarifies, through the lens of laboratory tissue tools, how validation, verification, and revalidation of IHC tests can be performed in order to develop and maintain high quality "fit-for-purpose" IHC testing in the era of precision medicine. This is the final part of the 4-part series "Evolution of Quality Assurance for Clinical Immunohistochemistry in the Era of Precision Medicine."

  18. New chemical probe technologies: applications to imaging and drug discovery (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Bogyo, Matthew

    2017-02-01

    Proteases are enzymes that play pathogenic roles in many common human diseases such as cancer, asthma, arthritis, atherosclerosis and infection by pathogens. Tools to dynamically monitor their activity can be used as diagnostic agents, as imaging contrast agents for intra-operative image guidance and for the identification of novel classes of protease-targeted drugs. I will describe our efforts to design and synthesize small molecule probes that produce a fluorescent signal upon binding to a protease target. We have identified probes that show tumor-specific retention, fast activation kinetics, and rapid systemic distribution making them useful for real-time fluorescence guided tumor resection and other diagnostic imaging applications.

  19. Endoscopic ultrasound-guided fine-needle aspiration needles: which one and in what situation?

    PubMed

    Karadsheh, Zeid; Al-Haddad, Mohammad

    2014-01-01

    Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is increasingly used as a diagnostic and therapeutic tool for pancreatic and other gastrointestinal disorders. Several factors affect the outcome of EUS-FNA, one of which is needle size. The decision to use a specific needle depends on factors including location, consistency, and type of the lesion; presence of onsite cytopathologist; and need for additional tissue procurement for histology. This review provides a balanced perspective on the use of different needle sizes available, highlighting the differences among them and potential niche applications of each to maximize diagnostic yield of EUS-FNA. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Non-IgE-mediated gastrointestinal food allergies.

    PubMed

    Biermé, Priscille; Nowak-Wegrzyn, Anna; Caubet, Jean-Christoph

    2017-12-01

    We focus on recent advances regarding the epidemiology, physiopathology, diagnosis and managements of non-IgE-mediated gastrointestinal food allergies (non-IgE-GI-FAs), particularly food protein-induced enterocolitis syndrome (FPIES). The first international FPIES diagnostic and management guidelines have been recently published. Although FPIES largely remains a diagnosis of exclusion, it may be more prevalent than previously thought. Ondansetron has emerged as a major tool for the treatment of FPIES acute reactions. Recent data also suggest an important role for innate immune cells in FPIES pathogenesis. Despite major advances in the diagnosis and management of non-IgE-GI-FAs, particularly FPIES, the lack of specific diagnostic tests and biomarkers to guide clinical management remains challenging.

  1. Portable Diagnostics Technology Assessment for Space Missions. Part 2; Market Survey

    NASA Technical Reports Server (NTRS)

    Nelson, Emily S.; Chait, Arnon

    2010-01-01

    A mission to Mars of several years duration requires more demanding standards for all onboard instruments than a 6-month mission to the Moon or the International Space Station. In Part 1, we evaluated generic technologies and suitability to NASA needs. This prior work considered crew safety, device maturity and flightworthiness, resource consumption, and medical value. In Part 2, we continue the study by assessing the current marketplace for reliable Point-of-Care diagnostics. The ultimate goal of this project is to provide a set of objective analytical tools to suggest efficient strategies for reaching specific medical targets for any given space mission as program needs, technological development, and scientific understanding evolve.

  2. [An odour of disease and decay: the nose as a diagnostic instrument].

    PubMed

    Bomers, Marije K; Smulders, Yvo M

    2015-01-01

    Infectious diseases and cancer change a patient's metabolism and hence the metabolic compounds produced. The composition of volatile organic compounds (VOCs) in exhaled breath or urine or stool samples can therefore be characteristic of a particular disease. In recent years many studies have been conducted into the training of animals, including dogs, to recognise diseases by smell. Besides trained animals, electronic noses (e-noses) are also being developed. These devices can identify disease-specific odour profiles in VOCs. Although the results of research in the field of scent diagnosis are promising, the medical community remains largely sceptical. We discuss applications of scent detection as a diagnostic tool in modern medicine.

  3. [Autism in children. Speech, behavior and motor activity point to diagnosis].

    PubMed

    Neumärker, K J

    2001-02-01

    Austistic disorders characteristically involve specific impairments of social skills, of the language and of stereotyped body movements. L Kanner and H. Asperger were the first to describe these psychopathologic features, which still form the core of the diagnostic criteria of contemporary psychiatric classification systems, ICD-10 and DSM-IV, in the category pervasive developmental disorders. Useful diagnostic tools have been developed to establish the clinical diagnosis. The results of research point to a predominantly genetic pathogenesis involving a complex interaction of multiple genes. While no causal treatments are available for these heterogenic disorders, there are many therapeutic concepts. Although some treatments may achieve significant improvements, autistic disorders usually mean a lifelong individual impairment.

  4. Development and Validation of a Novel Diagnostic Test for Human Brucellosis Using a Glyco-engineered Antigen Coupled to Magnetic Beads

    PubMed Central

    Ciocchini, Andrés E.; Rey Serantes, Diego A.; Melli, Luciano J.; Iwashkiw, Jeremy A.; Deodato, Bettina; Wallach, Jorge; Feldman, Mario F.; Ugalde, Juan E.; Comerci, Diego J.

    2013-01-01

    Brucellosis is a highly contagious zoonosis and still a major human health problem in endemic areas of the world. Although several diagnostic tools are available, most of them are difficult to implement especially in developing countries where complex health facilities are limited. Taking advantage of the identical structure and composition of the Brucella spp. and Yersinia enterocolitica O:9 O-polysaccharide, we explored the application of a recombinant Y. enterocolitica O:9-polysaccharide-protein conjugate (OAg-AcrA) as a novel antigen for diagnosis of human brucellosis. We have developed and validated an indirect immunoassay using OAg-AcrA coupled to magnetic beads. OAg-AcrA was produced and purified with high yields in Y. enterocolitica O:9 cells co-expressing the oligosaccharyltransferase PglB and the protein acceptor AcrA of Campylobacter jejuni without the need for culturing Brucella. Expression of PglB and AcrA in Y. enterocolitica resulted in the transfer of the host O-polysaccharide from its lipid carrier to AcrA. To validate the assay and determine the cutoff values, a receiver-operating characteristic analysis was performed using a panel of characterized serum samples obtained from healthy individuals and patients of different clinical groups. Our results indicate that, using this assay, it is possible to detect infection caused by the three main human brucellosis agents (B. abortus, B. melitensis and B. suis) and select different cutoff points to adjust sensitivity and specificity levels as needed. A cutoff value of 13.20% gave a sensitivity of 100% and a specificity of 98.57%, and a cutoff value of 16.15% resulted in a test sensitivity and specificity of 93.48% and 100%, respectively. The high diagnostic accuracy, low cost, reduced assay time and simplicity of this new glycoconjugate-magnetic beads assay makes it an attractive diagnostic tool for using not only in clinics and brucellosis reference laboratories but also in locations with limited laboratory infrastructure and/or minimally trained community health workers. PMID:23459192

  5. Evaluation of phenotypic detection methods for metallo-β-lactamases (MBLs) in clinical isolates of Pseudomonas aeruginosa.

    PubMed

    Peter, S; Lacher, A; Marschal, M; Hölzl, F; Buhl, M; Autenrieth, I; Kaase, M; Willmann, M

    2014-07-01

    Metallo-beta-lactamase (MBL) production in Pseudomonas aeruginosa is a growing issue across the globe. Fast and reliable diagnostic tools are needed for appropriate implementation of infection control measures. In this study we evaluated the performance of three commercial combined disk tests, two EDTA based in-house combined disk tests and the Carba NP test in comparison to molecular detection of MBL genes on 133 meropenem non-susceptible non-duplicate P. aeruginosa clinical isolates. The meropenem/DPA based commercial KPC + MBL-confirm ID kit (Rosco Diagnostica, Denmark) and the MASTDISCS™ ID carbapenemase (Enterobacteriaceae) detection disc set (MAST Diagnostics, UK) showed sensitivities of 31.1 % and 28.8 % and specificities of 69.3 % and 79.6 %, respectively. The total MBL confirm kit (Rosco Diagnostica, Denmark) contains imipenem/DPA and imipenem/EDTA combination disks. Evaluation of the single disk combinations revealed 84.4 % sensitivity and 81.8 % specificity for the imipenem/DPA assay and 86.7 % sensitivity and 51.1 % specificity for the imipenem/EDTA test. Applying both tests simultaneously resulted in a slightly higher sensitivity of 88.9 % but a lower specificity of 48.9 % when compared to the single tests alone. The Carba NP test showed 93.3 % sensitivity and 96.6 % specificity. All phenotypic combined disk tests lacked either sensitivity or specificity for the detection of MBL in P. aeruginosa. The Carba NP test showed excellent test properties, but suffers from drawbacks in handling and high costs. The optimal diagnostic approach needs to be chosen depending on the epidemiological situation, laboratory resources and availability of molecular confirmation tests.

  6. [Applications of DNA methylation markers in forensic medicine].

    PubMed

    Zhao, Gui-sen; Yang, Qing-en

    2005-02-01

    DNA methylation is a post-replication modification that is predominantly found in cytosines of the dinucleotide sequence CpG. Epigenetic information is stored in the distribution of the modified base 5-methylcytosine. DNA methylation profiles represent a more chemically and biologically stable source of molecular diagnostic information than RNA or most proteins. Recent advances attest to the great promise of DNA methylation markers as powerful future tools in the clinic. In the past decade, DNA methylation analysis has been revolutionized by two technological advances--bisulphite modification of DNA and methylation-specific polymerase chain reaction (MSP). The methylation pattern of human genome is space-time specific, sex-specific, parent-of-origin specific and disease specific, providing us an alternative way to solve forensic problems.

  7. Diagnostic performance of random urine samples using albumin concentration vs ratio of albumin to creatinine for microalbuminuria screening in patients with diabetes mellitus: a systematic review and meta-analysis.

    PubMed

    Wu, Hon-Yen; Peng, Yu-Sen; Chiang, Chih-Kang; Huang, Jenq-Wen; Hung, Kuan-Yu; Wu, Kwan-Dun; Tu, Yu-Kang; Chien, Kuo-Liong

    2014-07-01

    A random urine sample measuring the albumin concentration (UAC) without simultaneously measuring the urinary creatinine is less expensive than measuring the ratio of albumin to creatinine (ACR), but comparisons of their diagnostic performance for microalbuminuria screening among patients with diabetes mellitus (DM) have not been undertaken in previous meta-analyses. To compare the diagnostic performance of the UAC vs the ACR in random urine samples for microalbuminuria screening among patients with DM. Electronic literature searches of PubMed, MEDLINE, and Scopus for English-language publications from the earliest available date of indexing through July 31, 2012. Clinical studies assessing the UAC or the ACR of random urine samples in detecting the presence of microalbuminuria among patients with DM using a urinary albumin excretion rate of 30 to 300 mg/d in 24-hour timed urine collections as the criterion standard. Bivariate random-effects models for analysis and pooling of the diagnostic performance measures across studies, as well as comparisons between different screening tests. The primary end point was the diagnostic performance measures of the UAC or the ACR in random urine samples, as well as comparisons between them. We identified 14 studies, with a total of 2078 patients; 9 studies reported on the UAC, and 12 studies reported on the ACR. Meta-analysis showed pooled sensitivities of 0.85 and 0.87 for the UAC and the ACR, respectively, and pooled specificities of 0.88 and 0.88, respectively. No differences in sensitivity (P = .70), specificity (P = .63), or diagnostic odds ratios (P = .59) between the UAC and the ACR were found. The time point of urine collection did not affect the diagnostic performance of either test. The UAC and the ACR yielded high sensitivity and specificity for the detection of microalbuminuria. Because the diagnostic performance of the UAC is comparable to that of the ACR, our findings indicate that the UAC of random urine samples may become the screening tool of choice for the population with DM, considering the rising incidence of DM and the constrained health care resources in many countries.

  8. Phytoplasma-specific PCR primers based on sequences of the 16S-23S rRNA spacer region.

    PubMed Central

    Smart, C D; Schneider, B; Blomquist, C L; Guerra, L J; Harrison, N A; Ahrens, U; Lorenz, K H; Seemüller, E; Kirkpatrick, B C

    1996-01-01

    In order to develop a diagnostic tool to identify phytoplasmas and classify them according to their phylogenetic group, we took advantage of the sequence diversity of the 16S-23S intergenic spacer regions (SRs) of phytoplasmas. Ten PCR primers were developed from the SR sequences and were shown to amplify in a group-specific fashion. For some groups of phytoplasmas, such as elm yellows, ash yellows, and pear decline, the SR primer was paired with a specific primer from within the 16S rRNA gene. Each of these primer pairs was specific for a specific phytoplasma group, and they did not produce PCR products of the correct size from any other phytoplasma group. One primer was designed to anneal within the conserved tRNA(Ile) and, when paired with a universal primer, amplified all phytoplasmas tested. None of the primers produced PCR amplification products of the correct size from healthy plant DNA. These primers can serve as effective tools for identifying particular phytoplasmas in field samples. PMID:8702291

  9. Diagnostic performance characteristics of a rapid field test for anthrax in cattle.

    PubMed

    Muller, Janine; Gwozdz, Jacek; Hodgeman, Rachel; Ainsworth, Catherine; Kluver, Patrick; Czarnecki, Jill; Warner, Simone; Fegan, Mark

    2015-07-01

    Although diagnosis of anthrax can be made in the field with a peripheral blood smear, and in the laboratory with bacterial culture or molecular based tests, these tests require either considerable experience or specialised equipment. Here we report on the evaluation of the diagnostic sensitivity and specificity of a simple and rapid in-field diagnostic test for anthrax, the anthrax immunochromatographic test (AICT). The AICT detects the protective antigen (PA) component of the anthrax toxin present within the blood of an animal that has died from anthrax. The test provides a result in 15min and offers the advantage of avoiding the necessity for on-site necropsy and subsequent occupational risks and environmental contamination. The specificity of the test was determined by testing samples taken from 622 animals, not infected with Bacillus anthracis. Diagnostic sensitivity was estimated on samples taken from 58 animals, naturally infected with B. anthracis collected over a 10-year period. All samples used to estimate the diagnostic sensitivity and specificity of the AICT were also tested using the gold standard of bacterial culture. The diagnostic specificity of the test was estimated to be 100% (99.4-100%; 95% CI) and the diagnostic sensitivity was estimated to be 93.1% (83.3-98.1%; 95% CI) (Clopper-Pearson method). Four samples produced false negative AICT results. These were among 9 samples, all of which tested positive for B. anthracis by culture, where there was a time delay between collection and testing of >48h and/or the samples were collected from animals that were >48h post-mortem. A statistically significant difference (P<0.001; Fishers exact test) was found between the ability of the AICT to detect PA in samples from culture positive animals <48h post-mortem, 49 of 49, Se=100% (92.8-100%; 95% CI) compared with samples tested >48h post-mortem 5 of 9 Se=56% (21-86.3%; 95% CI) (Clopper-Pearson method). Based upon these results a post hoc cut-off for use of the AICT of 48h post-mortem was applied, Se=100% (92.8-100%; 95% CI) and Sp=100% (99.4-100%; 95% CI). The high diagnostic sensitivity and specificity and the simplicity of the AICT enables it to be used for active surveillance in areas with a history of anthrax, or used as a preliminary tool in investigating sudden, unexplained death in cattle. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Field evaluation of the photo-induced electron transfer fluorogenic primers (PET) real-time PCR for the detection of Plasmodium falciparum in Tanzania.

    PubMed

    Talundzic, Eldin; Maganga, Mussa; Masanja, Irene M; Peterson, David S; Udhayakumar, Venkatachalam; Lucchi, Naomi W

    2014-01-27

    Accurate diagnosis of malaria infections remains challenging, especially in the identification of submicroscopic infections. New molecular diagnostic tools that are inexpensive, sensitive enough to detect low-level infections and suitable in laboratory settings of resource-limited countries are required for malaria control and elimination programmes. Here the diagnostic potential of a recently developed photo-induced electron transfer fluorogenic primer (PET) real-time polymerase chain reaction (PCR) called PET-PCR was investigated. This study aimed to (i) evaluate the use of this assay as a method for the detection of both Plasmodium falciparum and other Plasmodium species infections in a developing country's diagnostic laboratory; and, (ii) determine the assay's sensitivity and specificity compared to a nested 18S rRNA PCR. Samples used in this study were obtained from a previous study conducted in the region of Iringa, Tanzania. A total of 303 samples from eight health facilities in Tanzania were utilized for this evaluation. All samples were screened using the multiplex PET-PCR assay designed to detect Plasmodium genus and P. falciparum initially in laboratory in Tanzania and then repeated at a reference laboratory at the CDC in the USA. Microscopy data was available for all the 303 samples. A subset of the samples were tested in a blinded fashion to find the sensitivity and specificity of the PET-PCR compared to the nested 18S rRNA PCR. Compared to microscopy, the PET-PCR assay was 59% more sensitive in detecting P. falciparum infections. The observed sensitivity and specificity were 100% (95% confidence interval (CI0.95) = 94-100%) and (CI0.95 = 96-100%), respectively, for the PET-PCR assay when compared to nested 18S rRNA PCR. When compared to 18S rRNA PCR, microscopy had a low sensitivity of 40% (CI0.95 = 23-61%) and specificity of 100% (CI0.95 = 96-100%). The PET-PCR results performed in the field laboratory in Tanzania were in 100% concordance with the results obtained at the reference laboratory in the USA. The PET-PCR is a new molecular diagnostic tool with similar performance characteristics as commonly used PCR methods that is less expensive, easy to use, and amiable to large scale-surveillance studies in developing country settings.

  11. The Validity of the Baby and Infant Screen for Children with aUtIsm Traits: Part 1 (BISCUIT-- Part 1)

    ERIC Educational Resources Information Center

    Matson, Johnny L.; Wilkins, Jonathan; Fodstad, Jill C.

    2011-01-01

    A top priority in the field of autism spectrum disorders (ASD) is the development of precise early diagnostic tools that can be completed with minimal time and training. We report on the convergent and divergent validity of the Baby and Infant Screen for Children with aUtIsm Traits (BISCUIT), specifically the BISCUIT-Part 1. Previous research with…

  12. Dental History Predictors of Caries Related Dental Emergencies.

    DTIC Science & Technology

    1981-11-01

    10+) 50% of those with U- lesions would be selected and only 4% of those without disease would be selected. The accuracy of such a system as well as...sufficient sensitivity, specificity, and diagnostic power to be useful as predictive tools. Dental health classification systems are typically only...predicted with some reliability given the intimacy of the relationship and the relatively long duration of the pre-emergency state. The incidence of

  13. Molecular diagnosis of Plasmodium ovale by photo-induced electron transfer fluorogenic primers: PET-PCR

    PubMed Central

    Akerele, David; Ljolje, Dragan; Talundzic, Eldin; Udhayakumar, Venkatachalam

    2017-01-01

    Accurate diagnosis of malaria infections continues to be challenging and elusive, especially in the detection of submicroscopic infections. Developing new malaria diagnostic tools that are sensitive enough to detect low-level infections, user friendly, cost effective and capable of performing large scale diagnosis, remains critical. We have designed novel self-quenching photo-induced electron transfer (PET) fluorogenic primers for the detection of P. ovale by real-time PCR. In our study, a total of 173 clinical samples, consisting of different malaria species, were utilized to test this novel PET-PCR primer. The sensitivity and specificity were calculated using nested-PCR as the reference test. The novel primer set demonstrated a sensitivity of 97.5% and a specificity of 99.2% (95% CI 85.2–99.8% and 95.2–99.9% respectively). Furthermore, the limit of detection for P. ovale was found to be 1 parasite/μl. The PET-PCR assay is a new molecular diagnostic tool with comparable performance to other commonly used PCR methods. It is relatively easy to perform, and amiable to large scale malaria surveillance studies and malaria control and elimination programs. Further field validation of this novel primer will be helpful to ascertain the utility for large scale malaria screening programs. PMID:28640824

  14. Molecular diagnosis of Plasmodium ovale by photo-induced electron transfer fluorogenic primers: PET-PCR.

    PubMed

    Akerele, David; Ljolje, Dragan; Talundzic, Eldin; Udhayakumar, Venkatachalam; Lucchi, Naomi W

    2017-01-01

    Accurate diagnosis of malaria infections continues to be challenging and elusive, especially in the detection of submicroscopic infections. Developing new malaria diagnostic tools that are sensitive enough to detect low-level infections, user friendly, cost effective and capable of performing large scale diagnosis, remains critical. We have designed novel self-quenching photo-induced electron transfer (PET) fluorogenic primers for the detection of P. ovale by real-time PCR. In our study, a total of 173 clinical samples, consisting of different malaria species, were utilized to test this novel PET-PCR primer. The sensitivity and specificity were calculated using nested-PCR as the reference test. The novel primer set demonstrated a sensitivity of 97.5% and a specificity of 99.2% (95% CI 85.2-99.8% and 95.2-99.9% respectively). Furthermore, the limit of detection for P. ovale was found to be 1 parasite/μl. The PET-PCR assay is a new molecular diagnostic tool with comparable performance to other commonly used PCR methods. It is relatively easy to perform, and amiable to large scale malaria surveillance studies and malaria control and elimination programs. Further field validation of this novel primer will be helpful to ascertain the utility for large scale malaria screening programs.

  15. Combinatorial Multidomain Mesoporous Chips and a Method for Fractionation, Stabilization, and Storage of Biomolecules

    NASA Technical Reports Server (NTRS)

    Tasciotti, Ennio (Inventor); Hu, Ye (Inventor); Ferrari, Mauro (Inventor); Bouamrani, Ali (Inventor); Liu, Xuewu (Inventor)

    2014-01-01

    A new fractionation device shows desirable features for exploratory screening and biomarker discovery. The constituent MSCs may be tailored for desired pore sizes and surface properties and for the sequestration and enrichment of extremely low abundant protein and peptides in desired ranges of the mass/charge spectrum. The MSCs are effective in yielding reproducible extracts from complex biological samples as small as 10 microliter in a time as short as 30 minutes. They are inexpensive to manufacture, and allow for scaled up production to attain the simultaneous processing of a large number of samples. The MSCs are multiplexed, label-free diagnostic tools with the potential of biological recognition moiety modification for enhanced specificity. The MSCs may store, protect and stabilize biological fluids, enabling the simplified and cost-effective collection and transportation of clinical samples. The MSC-based device may serve as a diagnostic tool to complement histopathology, imaging, and other conventional clinical techniques. The MSCs mediated identification of disease-specific protein signatures may help in the selection of personalized therapeutic combinations, in the real-time assessment of therapeutic efficacy and toxicity, and in the rational modulation of therapy based on the changes in the protein networks associated with the prognosis and the drug resistance of the disease.

  16. A New Interactive Screening Test for Autism Spectrum Disorders in Toddlers.

    PubMed

    Choueiri, Roula; Wagner, Sheldon

    2015-08-01

    To develop a clinically valid interactive level 2 screening assessment for autism spectrum disorders (ASD) in toddlers that is brief, easily administered, and scored by clinicians. We describe the development, training, standardization, and validation of the Rapid Interactive Screening Test for Autism in Toddlers (RITA-T) with ASD-specific diagnostic instruments. The RITA-T can be administered and scored in 10 minutes. We studied the validity of the RITA-T to distinguish between toddlers with ASD from toddlers with developmental delay (DD)/non-ASD in an early childhood clinic. We also evaluated the test's performance in toddlers with no developmental concerns. We identified a cutoff score based on sensitivity, specificity, and positive predictive value of the RITA-T that best differentiates between ASD and DD/non-ASD. A total of 61 toddlers were enrolled. RITA-T scores were correlated with ASD-specific diagnostic tools (r = 0.79; P < .01) and ASD clinical diagnoses (r = 0.77; P < .01). Mean scores were significantly different in subjects with ASD, those with DD/non-ASD, and those with no developmental concerns (20.8 vs 13 vs 10.6, respectively; P < .0001). At a cutoff score of >14 , the RITA-T had a sensitivity of 1.00, specificity of 0.84, and positive predictive value of 0.88 for identifying ASD risk in a high-risk group. The RITA-T is a promising new level 2 interactive screening tool for improving the early identification of ASD in toddlers in general pediatric and early intervention settings and allowing access to treatment. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Evaluation of diagnostic value of four tumor markers in bronchoalveolar lavage fluid of peripheral lung cancer.

    PubMed

    Li, Jian; Chen, Ping; Mao, Chao-Ming; Tang, Xing-Ping; Zhu, Li-Rong

    2014-06-01

    The diagnostic role of carcinoembryonic antigen (CEA), squamous cell carcinoma (SCC) antigen, Cyfra 21-1 and neuron-specific enolase (NSE) in the bronchoalveolar lavage fluid (BALF) for lung cancer is still controversial. The aim of this study was to evaluate the diagnostic value of these four tumor markers in BALF for peripheral lung cancer. We measured and compared the levels of CEA, SCC, Cyfra21-1 and NSE in BALF in 42 patients with peripheral lung cancer and 22 patients with benign lung disease. In the patients with peripheral lung cancer, the BAL was separately performed in the bronchus of the tumor-bearing lung and in the corresponding bronchus of the opposite healthy lung. The levels of CEA, SCC, Cyfra21-1 and NSE were significantly elevated in BALF from the tumor-bearing lung compared with the opposite healthy lung in the lung cancer patients (P < 0.001) or the benign lung disease patients (P < 0.005). The diagnostic sensitivities of Cyfra21-1 (86 and 76%), with a specificity of 91%, were the highest among the four tumor markers for the tumor-bearing lung versus the opposite healthy lung and benign lung disease. The combination of Cyfra21-1 and CEA increased the sensitivity to 93 and 86 percent, respectively. The assay of these tumor markers in BALF may be used as a diagnostic tool to complement a cytological examination in the diagnosis of peripheral lung cancer. © 2013 Wiley Publishing Asia Pty Ltd.

  18. Advancing the research agenda for diagnostic error reduction.

    PubMed

    Zwaan, Laura; Schiff, Gordon D; Singh, Hardeep

    2013-10-01

    Diagnostic errors remain an underemphasised and understudied area of patient safety research. We briefly summarise the methods that have been used to conduct research on epidemiology, contributing factors and interventions related to diagnostic error and outline directions for future research. Research methods that have studied epidemiology of diagnostic error provide some estimate on diagnostic error rates. However, there appears to be a large variability in the reported rates due to the heterogeneity of definitions and study methods used. Thus, future methods should focus on obtaining more precise estimates in different settings of care. This would lay the foundation for measuring error rates over time to evaluate improvements. Research methods have studied contributing factors for diagnostic error in both naturalistic and experimental settings. Both approaches have revealed important and complementary information. Newer conceptual models from outside healthcare are needed to advance the depth and rigour of analysis of systems and cognitive insights of causes of error. While the literature has suggested many potentially fruitful interventions for reducing diagnostic errors, most have not been systematically evaluated and/or widely implemented in practice. Research is needed to study promising intervention areas such as enhanced patient involvement in diagnosis, improving diagnosis through the use of electronic tools and identification and reduction of specific diagnostic process 'pitfalls' (eg, failure to conduct appropriate diagnostic evaluation of a breast lump after a 'normal' mammogram). The last decade of research on diagnostic error has made promising steps and laid a foundation for more rigorous methods to advance the field.

  19. Diagnostic accuracy of tests to detect Hepatitis C antibody: a meta-analysis and review of the literature.

    PubMed

    Tang, Weiming; Chen, Wen; Amini, Ali; Boeras, Debi; Falconer, Jane; Kelly, Helen; Peeling, Rosanna; Varsaneux, Olivia; Tucker, Joseph D; Easterbrook, Philippa

    2017-11-01

    Although direct-acting antivirals can achieve sustained virological response rates greater than 90% in Hepatitis C Virus (HCV) infected persons, at present the majority of HCV-infected individuals remain undiagnosed and therefore untreated. While there are a wide range of HCV serological tests available, there is a lack of formal assessment of their diagnostic performance. We undertook a systematic review and meta-analysis to evaluate he diagnostic accuracy of available rapid diagnostic tests (RDT) and laboratory based EIA assays in detecting antibodies to HCV. We used the PRISMA checklist and Cochrane guidance to develop our search protocol. The search strategy was registered in PROSPERO (CRD42015023567). The search focused on hepatitis C, diagnostic tests, and diagnostic accuracy within eight databases (MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Science Citation Index Expanded, Conference Proceedings Citation Index-Science, SCOPUS, Literatura Latino-Americana e do Caribe em Ciências da Saúde and WHO Global Index Medicus. Studies were included if they evaluated an assay to determine the sensitivity and specificity of HCV antibody (HCV Ab) in humans. Two reviewers independently extracted data and performed a quality assessment of the studies using the QUADAS tool. We pooled test estimates using the DerSimonian-Laird method, by using the software R and RevMan. 5.3. A total of 52 studies were identified that included 52,673 unique test measurements. Based on five studies, the pooled sensitivity and specificity of HCV Ab rapid diagnostic tests (RDTs) were 98% (95% CI 98-100%) and 100% (95% CI 100-100%) compared to an enzyme immunoassay (EIA) reference standard. High HCV Ab RDTs sensitivity and specificity were observed across screening populations (general population, high risk populations, and hospital patients) using different reference standards (EIA, nucleic acid testing, immunoblot). There were insufficient studies to undertake subanalyses based on HIV co-infection. Oral HCV Ab RDTs also had excellent sensitivity and specificity compared to blood reference tests, respectively at 94% (95% CI 93-96%) and 100% (95% CI 100-100%). Among studies that assessed individual oral RDTs, the eight studies revealed that OraQuick ADVANCE® had a slightly higher sensitivity (98%, 95% CI 97-98%) compared to the other oral brands (pooled sensitivity: 88%, 95% CI 84-92%). RDTs, including oral tests, have excellent sensitivity and specificity compared to laboratory-based methods for HCV antibody detection across a wide range of settings. Oral HCV Ab RDTs had good sensitivity and specificity compared to blood reference standards.

  20. Advances in the diagnosis of premenstrual syndrome and premenstrual dysphoric disorder.

    PubMed

    Futterman, Lori A

    2010-01-01

    Premenstrual disorders negatively impact the quality of life and functional ability of millions of women. The two generally recognized premenstrual disorders are premenstrual syndrome (PMS) and premenstrual dysphoric disorder (PMDD). These disorders are characterized by a wide variety of nonspecific mood, somatic and behavioral symptoms that occur only during the late luteal phase of a woman's cycle and disappear soon after the onset of menstruation. This paper reviews the diagnostic criteria for PMS and PMDD, describes some of the more common symptom diaries and other tools used to diagnose premenstrual disorders, and discusses the challenges inherent in diagnosing PMS and PMDD. A survey of peer-reviewed articles and relevant texts provided diagnostic criteria, descriptions of diagnostic tools and information about diagnostic challenges. The many nonspecific symptoms associated with premenstrual disorders complicate the diagnostic process. The use of proven symptom diaries and other diagnostic tools should aid in the differential diagnosis of premenstrual disorders. Patients need to report bothersome premenstrual symptoms, and clinicians should become more proficient in the diagnostic process in order to prevent underdiagnosis of these disorders.

  1. Software Users Manual (SUM): Extended Testability Analysis (ETA) Tool

    NASA Technical Reports Server (NTRS)

    Maul, William A.; Fulton, Christopher E.

    2011-01-01

    This software user manual describes the implementation and use the Extended Testability Analysis (ETA) Tool. The ETA Tool is a software program that augments the analysis and reporting capabilities of a commercial-off-the-shelf (COTS) testability analysis software package called the Testability Engineering And Maintenance System (TEAMS) Designer. An initial diagnostic assessment is performed by the TEAMS Designer software using a qualitative, directed-graph model of the system being analyzed. The ETA Tool utilizes system design information captured within the diagnostic model and testability analysis output from the TEAMS Designer software to create a series of six reports for various system engineering needs. The ETA Tool allows the user to perform additional studies on the testability analysis results by determining the detection sensitivity to the loss of certain sensors or tests. The ETA Tool was developed to support design and development of the NASA Ares I Crew Launch Vehicle. The diagnostic analysis provided by the ETA Tool was proven to be valuable system engineering output that provided consistency in the verification of system engineering requirements. This software user manual provides a description of each output report generated by the ETA Tool. The manual also describes the example diagnostic model and supporting documentation - also provided with the ETA Tool software release package - that were used to generate the reports presented in the manual

  2. The Clinical Utility of Methicillin Resistant Staphylococcus aureus (MRSA) Nasal Screening to Rule Out MRSA Pneumonia: A Diagnostic Meta-analysis with Antimicrobial Stewardship Implications.

    PubMed

    Parente, Diane M; Cunha, Cheston B; Mylonakis, Eleftherios; Timbrook, Tristan T

    2018-01-11

    Recent literature has highlighted MRSA nasal screening as a possible antimicrobial stewardship program (ASP) tool for avoiding unnecessary empiric MRSA therapy for pneumonia, yet current guidelines recommend MRSA therapy based on risk factors. The objective of this meta-analysis was to evaluate the diagnostic value of MRSA nasal screening in MRSA pneumonia. Pubmed and EMBASE were searched from inception to November 2016 for English studies evaluating MRSA nasal screening and development of MRSA pneumonia. Data analysis was performed using a bivariate random-effects model to estimate pooled sensitivity, specificity, and positive (PPV) and negative (NPV) predictive values. Twenty-two studies, comprising of 5,163 patients met our inclusion criteria. Pooled sensitivity and specificity of MRSA nares screen for all MRSA pneumonia types was 70.9% and 90.3%, respectively. With a 10% prevalence of potential MRSA pneumonia, the calculated PPV was 44.8% while the NPV was 96.5%. The pooled sensitivity and specificity for MRSA community-acquired pneumonia (CAP) and healthcare-associated pneumonia (HCAP) were at 85% and 92.1%, respectively. For CAP and HCAP both the PPV and NPV increased to 56.8% and 98.1%, respectively. In comparison, for MRSA ventilated-associated pneumonia (VAP), the sensitivity, specificity, PPV, NPV was 40.3%, 93.7%, 35.7%, and 94.8%, respectively. Nares screening for MRSA had a high specificity and NPV for ruling out MRSA pneumonia, particularly in cases of CAP/HCAP. Based on the NPV, utilization of MRSA nares screening is a valuable tool for AMS to streamline empiric antibiotic therapy, especially among patients with pneu. © The Author(s) 2018. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  3. What is a reflex? A guide for understanding disorders of consciousness.

    PubMed

    Fischer, David B; Truog, Robert D

    2015-08-11

    Uncertainty in diagnosing disorders of consciousness, and specifically in determining whether consciousness has been lost or retained, poses challenging scientific and ethical questions. Recent neuroimaging-based tests for consciousness have cast doubt on the reliability of behavioral criteria in assessing states of consciousness and generate new questions about the assumptions used in formulating coherent diagnostic criteria. The reflex, a foundational diagnostic tool, offers unique insight into these disorders; behaviors produced by unconscious patients are thought to be purely reflexive, whereas those produced by conscious patients can be volitional. Further investigation, however, reveals that reflexes cannot be reliably distinguished from conscious behaviors on the basis of any generalizable empirical characteristics. Ambiguity between reflexive and conscious behaviors undermines the capacity of the reflex to distinguish between disorders of consciousness and has implications for how these disorders should be conceptualized in future diagnostic criteria. © 2015 American Academy of Neurology.

  4. Biosensors-on-chip: a topical review

    NASA Astrophysics Data System (ADS)

    Chen, Sensen; Shamsi, Mohtashim H.

    2017-08-01

    This review will examine the integration of two fields that are currently at the forefront of science, i.e. biosensors and microfluidics. As a lab-on-a-chip (LOC) technology, microfluidics has been enriched by the integration of various detection tools for analyte detection and quantitation. The application of such microfluidic platforms is greatly increased in the area of biosensors geared towards point-of-care diagnostics. Together, the merger of microfluidics and biosensors has generated miniaturized devices for sample processing and sensitive detection with quantitation. We believe that microfluidic biosensors (biosensors-on-chip) are essential for developing robust and cost effective point-of-care diagnostics. This review is relevant to a variety of disciplines, such as medical science, clinical diagnostics, LOC technologies including MEMs/NEMs, and analytical science. Specifically, this review will appeal to scientists working in the two overlapping fields of biosensors and microfluidics, and will also help new scientists to find their directions in developing point-of-care devices.

  5. The Ritvo Autism Asperger Diagnostic Scale-Revised (RAADS-R): a scale to assist the diagnosis of Autism Spectrum Disorder in adults: an international validation study.

    PubMed

    Ritvo, Riva Ariella; Ritvo, Edward R; Guthrie, Donald; Ritvo, Max J; Hufnagel, Demetra H; McMahon, William; Tonge, Bruce; Mataix-Cols, David; Jassi, Amita; Attwood, Tony; Eloff, Johann

    2011-08-01

    The Ritvo Autism Asperger Diagnostic Scale-Revised (RAADS-R) is a valid and reliable instrument to assist the diagnosis of adults with Autism Spectrum Disorders (ASD). The 80-question scale was administered to 779 subjects (201 ASD and 578 comparisons). All ASD subjects met inclusion criteria: DSM-IV-TR, ADI/ADOS diagnoses and standardized IQ testing. Mean scores for each of the questions and total mean ASD vs. the comparison groups' scores were significantly different (p < .0001). Concurrent validity with Constantino Social Responsiveness Scale-Adult = 95.59%. Sensitivity = 97%, specificity = 100%, test-retest reliability r = .987. Cronbach alpha coefficients for the subscales and 4 derived factors were good. We conclude that the RAADS-R is a useful adjunct diagnostic tool for adults with ASD.

  6. The value and validation of broad spectrum biosensors for diagnosis and biodefense

    PubMed Central

    Metzgar, David; Sampath, Rangarajan; Rounds, Megan A; Ecker, David J

    2013-01-01

    Broad spectrum biosensors capable of identifying diverse organisms are transitioning from the realm of research into the clinic. These technologies simultaneously capture signals from a wide variety of biological entities using universal processes. Specific organisms are then identified through bioinformatic signature-matching processes. This is in contrast to currently accepted molecular diagnostic technologies, which utilize unique reagents and processes to detect each organism of interest. This paradigm shift greatly increases the breadth of molecular diagnostic tools with little increase in biochemical complexity, enabling simultaneous diagnostic, epidemiologic, and biothreat surveillance capabilities at the point of care. This, in turn, offers the promise of increased biosecurity and better antimicrobial stewardship. Efficient realization of these potential gains will require novel regulatory paradigms reflective of the generalized, information-based nature of these assays, allowing extension of empirical data obtained from readily available organisms to support broader reporting of rare, difficult to culture, or extremely hazardous organisms. PMID:24128433

  7. Theranostics in nuclear medicine practice.

    PubMed

    Yordanova, Anna; Eppard, Elisabeth; Kürpig, Stefan; Bundschuh, Ralph A; Schönberger, Stefan; Gonzalez-Carmona, Maria; Feldmann, Georg; Ahmadzadehfar, Hojjat; Essler, Markus

    2017-01-01

    The importance of personalized medicine has been growing, mainly due to a more urgent need to avoid unnecessary and expensive treatments. In nuclear medicine, the theranostic approach is an established tool for specific molecular targeting, both for diagnostics and therapy. The visualization of potential targets can help predict if a patient will benefit from a particular treatment. Thanks to the quick development of radiopharmaceuticals and diagnostic techniques, the use of theranostic agents has been continually increasing. In this article, important milestones of nuclear therapies and diagnostics in the context of theranostics are highlighted. It begins with a well-known radioiodine therapy in patients with thyroid cancer and then progresses through various approaches for the treatment of advanced cancer with targeted therapies. The aim of this review was to provide a summary of background knowledge and current applications, and to identify the advantages of targeted therapies and imaging in nuclear medicine practices.

  8. Theranostics in nuclear medicine practice

    PubMed Central

    Yordanova, Anna; Eppard, Elisabeth; Kürpig, Stefan; Bundschuh, Ralph A; Schönberger, Stefan; Gonzalez-Carmona, Maria; Feldmann, Georg; Ahmadzadehfar, Hojjat; Essler, Markus

    2017-01-01

    The importance of personalized medicine has been growing, mainly due to a more urgent need to avoid unnecessary and expensive treatments. In nuclear medicine, the theranostic approach is an established tool for specific molecular targeting, both for diagnostics and therapy. The visualization of potential targets can help predict if a patient will benefit from a particular treatment. Thanks to the quick development of radiopharmaceuticals and diagnostic techniques, the use of theranostic agents has been continually increasing. In this article, important milestones of nuclear therapies and diagnostics in the context of theranostics are highlighted. It begins with a well-known radioiodine therapy in patients with thyroid cancer and then progresses through various approaches for the treatment of advanced cancer with targeted therapies. The aim of this review was to provide a summary of background knowledge and current applications, and to identify the advantages of targeted therapies and imaging in nuclear medicine practices. PMID:29042793

  9. Evaluation of a focussed protocol for hand-held echocardiography and computer-assisted auscultation in detecting latent rheumatic heart disease in scholars.

    PubMed

    Zühlke, Liesl J; Engel, Mark E; Nkepu, Simpiwe; Mayosi, Bongani M

    2016-08-01

    Introduction Echocardiography is the diagnostic test of choice for latent rheumatic heart disease. The utility of echocardiography for large-scale screening is limited by high cost, complex diagnostic protocols, and time to acquire multiple images. We evaluated the performance of a brief hand-held echocardiography protocol and computer-assisted auscultation in detecting latent rheumatic heart disease with or without pathological murmur. A total of 27 asymptomatic patients with latent rheumatic heart disease based on the World Heart Federation criteria and 66 healthy controls were examined by standard cardiac auscultation to detect pathological murmur. Hand-held echocardiography using a focussed protocol that utilises one view - that is, the parasternal long-axis view - and one measurement - that is, mitral regurgitant jet - and a computer-assisted auscultation utilising an automated decision tool were performed on all patients. The sensitivity and specificity of computer-assisted auscultation in latent rheumatic heart disease were 4% (95% CI 1.0-20.4%) and 93.7% (95% CI 84.5-98.3%), respectively. The sensitivity and specificity of the focussed hand-held echocardiography protocol for definite rheumatic heart disease were 92.3% (95% CI 63.9-99.8%) and 100%, respectively. The test reliability of hand-held echocardiography was 98.7% for definite and 94.7% for borderline disease, and the adjusted diagnostic odds ratios were 1041 and 263.9 for definite and borderline disease, respectively. Computer-assisted auscultation has extremely low sensitivity but high specificity for pathological murmur in latent rheumatic heart disease. Focussed hand-held echocardiography has fair sensitivity but high specificity and diagnostic utility for definite or borderline rheumatic heart disease in asymptomatic patients.

  10. Sensitivity, Specificity, Predictive Values, and Accuracy of Three Diagnostic Tests to Predict Inferior Alveolar Nerve Blockade Failure in Symptomatic Irreversible Pulpitis

    PubMed Central

    Rodríguez-Wong, Laura; Noguera-González, Danny; Esparza-Villalpando, Vicente; Montero-Aguilar, Mauricio

    2017-01-01

    Introduction The inferior alveolar nerve block (IANB) is the most common anesthetic technique used on mandibular teeth during root canal treatment. Its success in the presence of preoperative inflammation is still controversial. The aim of this study was to evaluate the sensitivity, specificity, predictive values, and accuracy of three diagnostic tests used to predict IANB failure in symptomatic irreversible pulpitis (SIP). Methodology A cross-sectional study was carried out on the mandibular molars of 53 patients with SIP. All patients received a single cartridge of mepivacaine 2% with 1 : 100000 epinephrine using the IANB technique. Three diagnostic clinical tests were performed to detect anesthetic failure. Anesthetic failure was defined as a positive painful response to any of the three tests. Sensitivity, specificity, predictive values, accuracy, and ROC curves were calculated and compared and significant differences were analyzed. Results IANB failure was determined in 71.7% of the patients. The sensitivity scores for the three tests (lip numbness, the cold stimuli test, and responsiveness during endodontic access) were 0.03, 0.35, and 0.55, respectively, and the specificity score was determined as 1 for all of the tests. Clinically, none of the evaluated tests demonstrated a high enough accuracy (0.30, 0.53, and 0.68 for lip numbness, the cold stimuli test, and responsiveness during endodontic access, resp.). A comparison of the areas under the curve in the ROC analyses showed statistically significant differences between the three tests (p < 0.05). Conclusion None of the analyzed tests demonstrated a high enough accuracy to be considered a reliable diagnostic tool for the prediction of anesthetic failure. PMID:28694714

  11. Accuracy of early detection of colorectal tumours by stool methylation markers: A meta-analysis

    PubMed Central

    Zhang, Hu; Qi, Jian; Wu, Ya-Qiong; Zhang, Ping; Jiang, Jun; Wang, Qi-Xian; Zhu, You-Qing

    2014-01-01

    AIM: To evaluate the accuracy of methylation of genes in stool samples for diagnosing colorectal tumours. METHODS: Electronic databases including PubMed, Web of Science, Chinese Journals Full-Text Database and Wanfang Journals Full-Text Database were searched to find relevant original articles about methylated genes to be used in diagnosing colorectal tumours. A quality assessment of diagnostic accuracy studies tool (QADAS) was used to evaluate the quality of the included articles, and the Meta-disc 1.4 and SPSS 13.0 software programs were used for data analysis. RESULTS: Thirty-seven articles met the inclusion criteria, and 4484 patients were included. The sensitivity and specificity for the detection of colorectal cancer (CRC) were 73% (95%CI: 71%-75%) and 92% (95%CI: 90%-93%), respectively. For adenoma, the sensitivity and specificity were 51% (95%CI: 47%-54%) and 92% (95%CI: 90%-93%), respectively. Pooled diagnostic performance of SFRP2 methylation for CRC provided the following results: the sensitivity was 79% (95%CI: 75%-82%), the specificity was 93% (95%CI: 90%-96%), the diagnostic OR was 47.57 (95%CI: 20.08-112.72), the area under the curve was 0.9565. Additionally, the results of accuracy of SFRP2 methylation for detecting colorectal adenomas were as follows: sensitivity was 43% (95%CI: 38%-49%), specificity was 94% (95%CI: 91%-97%), the diagnostic OR was 11.06 (95%CI: 5.77-21.18), and the area under the curve was 0.9563. CONCLUSION: Stool-based DNA testing may be useful for noninvasively diagnosing colorectal tumours and SFRP2 methylation is a promising marker that has great potential in early CRC diagnosis. PMID:25320544

  12. The diagnostic accuracy of screening questionnaires for the identification of adults with epilepsy: a systematic review.

    PubMed

    Keezer, Mark R; Bouma, Hanni K; Wolfson, Christina

    2014-11-01

    To describe the diagnostic accuracy of screening questionnaires to identify epilepsy in adults, we performed a systematic review of diagnostic studies that assessed the sensitivity and specificity of such screening questionnaires as compared to a physician's clinical assessment. We searched Ovid MEDLINE (1946 to present) and Ovid EMBASE (1947 to present) for studies that estimated the sensitivity and specificity of nonphysician administered screening questionnaires for adults with epilepsy. Both telephone and in-person administered questionnaires were included, whether applied to population or hospital/clinic-based cohorts. The risk of bias was assessed using the Quality Assessment of Diagnostic Studies-2 (QUADAS-2) tool. Our initial search strategy resulted in 917 records. We found nine studies eligible for inclusion. The estimated sensitivity and specificity of the questionnaires used to identify persons with a lifetime history of epilepsy ranged from 81.5% to 100% and 65.6% to 99.2%, respectively. The sensitivity and specificity of these questionnaires in identifying persons with active epilepsy ranged from 48.6% to 100% and 73.9% to 99.9%, respectively. Overall we found a high risk of bias in patient selection and study flow in the majority of studies. We identified nine validation studies of epilepsy screening questionnaires, summarized their study characteristics, presented their results, and performed a rigorous quality assessment. This review serves as a basis for future studies by providing a systematic review of existing work. Future research addressing previous limitations will ultimately allow us to more accurately estimate the burden and risk of epilepsy in the general population. Wiley Periodicals, Inc. © 2014 International League Against Epilepsy.

  13. Sensitivity and specificity of the amer dizziness diagnostic scale (adds) for patients with vestibular disorders.

    PubMed

    Al Saif, Amer; Alsenany, Samira

    2015-01-01

    [Purpose] To investigate the sensitivity and specificity of a newly developed diagnostic tool, the Amer Dizziness Diagnostic Scale (ADDS), to evaluate and differentially diagnose vestibular disorder and to identify the strengths and weaknesses of the scale and its usefulness in clinical practice. [Subjects and Methods] Two hundred subjects of both genders (72 males, 128 females) aged between 18 to 60 (49.5±7.8) who had a history of vertigo and/or dizziness symptoms for this previous two weeks or less were recruited for the study. All subjects were referred by otolaryngologists, neurologists or family physicians in and around Jeddah, Kingdom of Saudi Arabia. On the first clinic visit, all the patients were evaluated once using the ADDS, following which they underwent routine testing of clinical signs and symptoms, audiometry, and a neurological examination, coupled with tests of Vestibulo-Ocular Reflex function, which often serves as the "gold standard" for determining the probability of a vestibular deficit. [Results] The results show that the ADDS strongly correlated with "true-positive" and "true-negative" responses for determining the probability of a vestibular disorder (r =0.95). A stepwise linear regression was conducted and the results indicate that the ADDS was a significant predictor of "true-positive" and "true-negative" responses in vestibular disorders (R(2) =0.90). Approximately 90% of the variability in the vestibular gold standard test was explained by its relationship to the ADDS. Moreover, the ADDS was found to have a sensitivity of 96% and a specificity of 96%. [Conclusion] This study showed that the Amer Dizziness Diagnostic Scale has high sensitivity and specificity and that it can be used as a method of differential diagnosis for patients with vestibular disorders.

  14. Accuracy of early detection of colorectal tumours by stool methylation markers: a meta-analysis.

    PubMed

    Zhang, Hu; Qi, Jian; Wu, Ya-Qiong; Zhang, Ping; Jiang, Jun; Wang, Qi-Xian; Zhu, You-Qing

    2014-10-14

    To evaluate the accuracy of methylation of genes in stool samples for diagnosing colorectal tumours. Electronic databases including PubMed, Web of Science, Chinese Journals Full-Text Database and Wanfang Journals Full-Text Database were searched to find relevant original articles about methylated genes to be used in diagnosing colorectal tumours. A quality assessment of diagnostic accuracy studies tool (QADAS) was used to evaluate the quality of the included articles, and the Meta-disc 1.4 and SPSS 13.0 software programs were used for data analysis. Thirty-seven articles met the inclusion criteria, and 4484 patients were included. The sensitivity and specificity for the detection of colorectal cancer (CRC) were 73% (95%CI: 71%-75%) and 92% (95%CI: 90%-93%), respectively. For adenoma, the sensitivity and specificity were 51% (95%CI: 47%-54%) and 92% (95%CI: 90%-93%), respectively. Pooled diagnostic performance of SFRP2 methylation for CRC provided the following results: the sensitivity was 79% (95%CI: 75%-82%), the specificity was 93% (95%CI: 90%-96%), the diagnostic OR was 47.57 (95%CI: 20.08-112.72), the area under the curve was 0.9565. Additionally, the results of accuracy of SFRP2 methylation for detecting colorectal adenomas were as follows: sensitivity was 43% (95%CI: 38%-49%), specificity was 94% (95%CI: 91%-97%), the diagnostic OR was 11.06 (95%CI: 5.77-21.18), and the area under the curve was 0.9563. Stool-based DNA testing may be useful for noninvasively diagnosing colorectal tumours and SFRP2 methylation is a promising marker that has great potential in early CRC diagnosis.

  15. Head-To-Head Comparison Between High- and Standard-b-Value DWI for Detecting Prostate Cancer: A Systematic Review and Meta-Analysis.

    PubMed

    Woo, Sungmin; Suh, Chong Hyun; Kim, Sang Youn; Cho, Jeong Yeon; Kim, Seung Hyup

    2018-01-01

    The purpose of this study was to perform a head-to-head comparison between high-b-value (> 1000 s/mm 2 ) and standard-b-value (800-1000 s/mm 2 ) DWI regarding diagnostic performance in the detection of prostate cancer. The MEDLINE and EMBASE databases were searched up to April 1, 2017. The analysis included diagnostic accuracy studies in which high- and standard-b-value DWI were used for prostate cancer detection with histopathologic examination as the reference standard. Methodologic quality was assessed with the revised Quality Assessment of Diagnostic Accuracy Studies tool. Sensitivity and specificity of all studies were calculated and were pooled and plotted in a hierarchic summary ROC plot. Meta-regression and multiple-subgroup analyses were performed to compare the diagnostic performances of high- and standard-b-value DWI. Eleven studies (789 patients) were included. High-b-value DWI had greater pooled sensitivity (0.80 [95% CI, 0.70-0.87]) (p = 0.03) and specificity (0.92 [95% CI, 0.87-0.95]) (p = 0.01) than standard-b-value DWI (sensitivity, 0.78 [95% CI, 0.66-0.86]); specificity, 0.87 [95% CI, 0.77-0.93] (p < 0.01). Multiple-subgroup analyses showed that specificity was consistently higher for high- than for standard-b-value DWI (p ≤ 0.05). Sensitivity was significantly higher for high- than for standard-b-value DWI only in the following subgroups: peripheral zone only, transition zone only, multiparametric protocol (DWI and T2-weighted imaging), visual assessment of DW images, and per-lesion analysis (p ≤ 0.04). In a head-to-head comparison, high-b-value DWI had significantly better sensitivity and specificity for detection of prostate cancer than did standard-b-value DWI. Multiple-subgroup analyses showed that specificity was consistently superior for high-b-value DWI.

  16. 3D-CAM: Derivation and Validation of a 3-Minute Diagnostic Interview for CAM-defined Delirium

    PubMed Central

    Marcantonio, Edward R.; Ngo, Long H.; O’Connor, Margaret; Jones, Richard N.; Crane, Paul K.; Metzger, Eran D.; Inouye, Sharon K.

    2015-01-01

    Background Delirium is common, morbid, and costly, yet remains often unrecognized in most clinical settings. The Confusion Assessment Method (CAM) is the most widely used diagnostic algorithm, and operationalizing its features would represent a substantial advance for clinical care. Objective To derive the 3D-CAM, a new 3-minute diagnostic assessment for CAM-defined delirium, and to validate it against a clinical reference standard. Design Diagnostic test study Setting 4 general medicine units in an academic medical center Participants 201 inpatients aged ≥ 75 years old Measurements We identified 20 items that best operationalized the 4 CAM diagnostic features to create the 3D-CAM. For prospective validation, 3D-CAM assessments were administered by trained research assistants. Independently, clinicians performed an extensive assessment that included patient interviews, family interviews, and review of the medical record. These data were considered by an expert panel to determine the presence or absence of delirium and dementia (reference standard). We compared the 3D-CAM delirium determination to the reference standard in all patients and in subgroups with and without dementia. Results The 201 participants in the prospective validation study had mean age (SD) of 84 (5.5) years, and 27% had dementia. The expert panel identified delirium in 21%. Median administration time for 3D-CAM was 3 minutes (inter-quartile range: 2–5 minutes). The sensitivity [95% CI] of 3D-CAM was 95% [84%, 99%] and the specificity was 94% [90%, 97%]. The 3D-CAM performed well in patients both with dementia (sensitivity=96% [82%, 100%], specificity=86% [67%, 96%]) and without dementia (sensitivity=93% [66%, 100%], specificity=96% [91%,99%]). Limitations Limited to single center, cross-sectional, and medicine patients only Conclusion The 3D-CAM operationalizes the CAM algorithm using a 3-minute structured assessment with high sensitivity and specificity relative to a reference standard and could be an important tool for improving recognition of delirium. PMID:25329203

  17. Diagnostic yield of endobronchial ultrasound-guided transbronchial needle aspiration for mediastinal staging in lung cancer*

    PubMed Central

    Fernández-Bussy, Sebastián; Labarca, Gonzalo; Canals, Sofia; Caviedes, Iván; Folch, Erik; Majid, Adnan

    2015-01-01

    OBJECTIVE: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive diagnostic test with a high diagnostic yield for suspicious central pulmonary lesions and for mediastinal lymph node staging. The main objective of this study was to describe the diagnostic yield of EBUS-TBNA for mediastinal lymph node staging in patients with suspected lung cancer. METHODS: Prospective study of patients undergoing EBUS-TBNA for diagnosis. Patients ≥ 18 years of age were recruited between July of 2010 and August of 2013. We recorded demographic variables, radiological characteristics provided by axial CT of the chest, location of the lesion in the mediastinum as per the International Association for the Study of Lung Cancer classification, and definitive diagnostic result (EBUS with a diagnostic biopsy or a definitive diagnostic method). RESULTS: Our analysis included 354 biopsies, from 145 patients. Of those 145 patients, 54.48% were male. The mean age was 63.75 years. The mean lymph node size was 15.03 mm, and 90 lymph nodes were smaller than 10.0 mm. The EBUS-TBNA method showed a sensitivity of 91.17%, a specificity of 100.0%, and a negative predictive value of 92.9%. The most common histological diagnosis was adenocarcinoma. CONCLUSIONS: EBUS-TBNA is a diagnostic tool that yields satisfactory results in the staging of neoplastic mediastinal lesions. PMID:26176519

  18. Rapid molecular diagnostics for multi-drug resistant tuberculosis in India.

    PubMed

    Ramachandran, Rajeswari; Muniyandi, M

    2018-03-01

    Rapid molecular diagnostic methods help in the detection of TB and Rifampicin resistance. These methods detect TB early, are accurate and play a crucial role in reducing the burden of drug resistant tuberculosis. Areas covered: This review analyses rapid molecular diagnostic tools used in the diagnosis of MDR-TB in India, such as the Line Probe Assay and GeneXpert. We have discussed the burden of MDR-TB and the impact of recent diagnostic tools on case detection and treatment outcomes. This review also discusses the costs involved in establishing these new techniques in India. Expert commentary: Molecular methods have considerable advantages for the programmatic management of drug resistant TB. These include speed, standardization of testing, potentially high throughput and reduced laboratory biosafety requirements. There is a desperate need for India to adopt modern, rapid, molecular tools with point-of-care tests being currently evaluated. New molecular diagnostic tests appear to be cost effective and also help in detecting missing cases. There is enough evidence to support the scaling up of these new tools in India.

  19. The Identification of Novel Diagnostic Marker Genes for the Detection of Beer Spoiling Pediococcus damnosus Strains Using the BlAst Diagnostic Gene findEr

    PubMed Central

    Schmid, Jonas; Zehe, Anja; Vogel, Rudi F.

    2016-01-01

    As the number of bacterial genomes increases dramatically, the demand for easy to use tools with transparent functionality and comprehensible output for applied comparative genomics grows as well. We present BlAst Diagnostic Gene findEr (BADGE), a tool for the rapid prediction of diagnostic marker genes (DMGs) for the differentiation of bacterial groups (e.g. pathogenic / nonpathogenic). DMG identification settings can be modified easily and installing and running BADGE does not require specific bioinformatics skills. During the BADGE run the user is informed step by step about the DMG finding process, thus making it easy to evaluate the impact of chosen settings and options. On the basis of an example with relevance for beer brewing, being one of the oldest biotechnological processes known, we show a straightforward procedure, from phenotyping, genome sequencing, assembly and annotation, up to a discriminant marker gene PCR assay, making comparative genomics a means to an end. The value and the functionality of BADGE were thoroughly examined, resulting in the successful identification and validation of an outstanding novel DMG (fabZ) for the discrimination of harmless and harmful contaminations of Pediococcus damnosus, which can be applied for spoilage risk determination in breweries. Concomitantly, we present and compare five complete P. damnosus genomes sequenced in this study, finding that the ability to produce the unwanted, spoilage associated off-flavor diacetyl is a plasmid encoded trait in this important beer spoiling species. PMID:27028007

  20. A dielectrophoretic method of discrimination between normal oral epithelium, and oral and oropharyngeal cancer in a clinical setting.

    PubMed

    Graham, K A; Mulhall, H J; Labeed, F H; Lewis, M P; Hoettges, K F; Kalavrezos, N; McCaul, J; Liew, C; Porter, S; Fedele, S; Hughes, M P

    2015-08-07

    Despite the accessibility of the oral cavity to clinical examination, delays in diagnosis of oral and oropharyngeal carcinoma (OOPC) are observed in a large majority of patients, with negative impact on prognosis. Diagnostic aids might help detection and improve early diagnosis, but there remains little robust evidence supporting the use of any particular diagnostic technology at the moment. The aim of the present feasibility first-in-human study was to evaluate the preliminary diagnostic validity of a novel technology platform based on dielectrophoresis (DEP). DEP does not require labeling with antibodies or stains and it is an ideal tool for rapid analysis of cell properties. Cells from OOPC/dysplasia tissue and healthy oral mucosa were collected from 57 study participants via minimally-invasive brush biopsies and tested with a prototype DEP platform using median membrane midpoint frequency as main analysis parameter. Results indicate that the current DEP platform can discriminate between brush biopsy samples from cancerous and healthy oral tissue with a diagnostic sensitivity of 81.6% and a specificity of 81.0%. The present ex vivo results support the potential application of DEP testing for identification of OOPC. This result indicates that DEP has the potential to be developed into a low-cost, rapid platform as an assistive tool for the early identification of oral cancer in primary care; given the rapid, minimally-invasive and non-expensive nature of the test, dielectric characterization represents a promising platform for cost-effective early cancer detection.

  1. Diagnosis of stinging insect allergy: utility of cellular in-vitro tests.

    PubMed

    Scherer, Kathrin; Bircher, Andreas J; Heijnen, Ingmar Afm

    2009-08-01

    Diagnosis of stinging insect allergy is based on a detailed history, venom skin tests, and detection of venom-specific IgE. As an additional diagnostic tool, basophil responsiveness to venom allergens has been shown to be helpful in selected patients. This review summarizes the current diagnostic procedures for stinging insect allergy and discusses the latest developments in cellular in-vitro tests. Cellular assays have been evaluated in patients with Hymenoptera venom allergy. The diagnostic performance of the cellular mediator release test is similar to that of the flow cytometric basophil activation test (BAT), but the BAT has been the most intensively studied. BAT offers the possibility to assess basophil reactivity to allergens in their natural environment and to simultaneously analyze surface marker expression and intracellular signaling. It has been demonstrated that BAT represents a valuable additional diagnostic tool in selected patients when used in combination with other well established tests. A major limitation is the current lack of unified, standardized protocols. Flow cytometry offers huge possibilities to enhance knowledge of basophil functions. The BAT may be used as an additional test to confirm the diagnosis of stinging insect allergy in selected patients, provided that it is performed by an experienced laboratory using a validated assay. Test results have to be interpreted by clinicians familiar with the methodological aspects. The utility of the BAT to confirm allergy diagnosis and to predict the risk of subsequent systemic reactions may be improved by combined analysis of multiple surface markers and intracellular signaling pathways.

  2. Is Diagnostic Performance of Quantitative 2D-Shear Wave Elastography Optimal for Clinical Classification of Benign and Malignant Thyroid Nodules?: A Systematic Review and Meta-analysis.

    PubMed

    Nattabi, Haliimah A; Sharif, Norhafidzah M; Yahya, Noorazrul; Ahmad, Rozilawati; Mohamad, Mazlyfarina; Zaki, Faizah M; Yusoff, Ahmad N

    2017-10-17

    This study is a dedicated 2D-shear wave elastography (2D-SWE) review aimed at systematically eliciting up-to-date evidence of its clinical value in differential diagnosis of benign and malignant thyroid nodules. PubMed, Web of Science, and Scopus databases were searched for studies assessing the diagnostic value of 2D-SWE for thyroid malignancy risk stratification published until December 2016. The retrieved titles and abstracts were screened and evaluated according to the predefined inclusion and exclusion criteria. Methodological quality of the studies was assessed using the Quality Assessment of Studies of Diagnostic Accuracy included in Systematic Review 2 (QUADAS-2) tool. Extracted 2D-SWE diagnostic performance data were meta-analyzed to assess the summary sensitivity, specificity, and area under the receiver operating characteristic curve. After stepwise review, 14 studies in which 2D-SWE was used to evaluate 2851 thyroid nodules (1092 malignant, 1759 benign) from 2139 patients were selected for the current study. Study quality on QUADAS-2 assessment was moderate to high. The summary sensitivity, specificity and area under the receiver operating characteristic curve of 2D-SWE for differential diagnosis of benign and malignant thyroid nodules were 0.66 (95% confidence interval [CI]: 0.64-0.69), 0.78 (CI: 0.76-0.80), and 0.851 (Q* = 0.85), respectively. The pooled diagnostic odds ratio, negative likelihood ratio, and positive likelihood ratio were 12.73 (CI: 8.80-18.43), 0.31 (CI: 0.22-0.44), and 3.87 (CI: 2.83-5.29), respectively. Diagnostic performance of quantitative 2D-SWE for malignancy risk stratification of thyroid nodules is suboptimal with mediocre sensitivity and specificity, contrary to earlier reports of excellence. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  3. Stimuli-responsive nanotherapeutics for precision drug delivery and cancer therapy.

    PubMed

    Qiao, Yiting; Wan, Jianqin; Zhou, Liqian; Ma, Wen; Yang, Yuanyuan; Luo, Weixuan; Yu, Zhiqiang; Wang, Hangxiang

    2018-05-04

    Cancer remains one of the world's leading causes of death. However, most conventional chemotherapeutic drugs only show a narrow therapeutic window in patients because of their inability to discriminate cancer cells from healthy cells. Nanoparticle-based therapeutics (termed nanotherapeutics) have emerged as potential solutions to mitigate many obstacles posed by these free drugs. Deep insights into knowledge of the tumor microenvironment and materials science make it possible to construct nanotherapeutics that are able to release cargoes in response to a variety of internal stimuli and external triggers. Therefore, such highly sophisticated nanosystems could help impede the premature release of toxic drugs in the blood circulation or healthy tissues, thus enhancing the safety profiles of encapsulated drugs. In this context, this review offers a comprehensive overview of several specific stimuli, including internal stimuli (e.g., pH, temperature, enzyme, redox, and H 2 O 2 ) and external stimuli (e.g., magnetic, photo, and ultrasound). We envision that applications of these smart nanotherapeutics can benefit cancer patients and provide a good chance for clinical translation of many nanoparticle formulas. This article is categorized under: Therapeutic Approaches and Drug Discovery > Nanomedicine for Oncologic Disease Diagnostic Tools > Diagnostic Nanodevices Diagnostic Tools > in vitro Nanoparticle-Based Sensing. © 2018 Wiley Periodicals, Inc.

  4. KS-Detect – Validation of Solar Thermal PCR for the Diagnosis of Kaposi’s Sarcoma Using Pseudo-Biopsy Samples

    PubMed Central

    Snodgrass, Ryan; Gardner, Andrea; Jiang, Li; Fu, Cheng; Cesarman, Ethel; Erickson, David

    2016-01-01

    Resource-limited settings present unique engineering challenges for medical diagnostics. Diagnosis is often needed for those unable to reach central healthcare systems, making portability and independence from traditional energy infrastructure essential device parameters. In 2014, our group presented a microfluidic device that performed a solar-powered variant of the polymerase chain reaction, which we called solar thermal PCR. In this work, we expand on our previous effort by presenting an integrated, portable, solar thermal PCR system targeted towards the diagnosis of Kaposi’s sarcoma. We call this system KS-Detect, and we now report the system’s performance as a diagnostic tool using pseudo-biopsy samples made from varying concentrations of human lymphoma cell lines positive for the KS herpesvirus (KSHV). KS-Detect achieved 83% sensitivity and 70% specificity at high (≥10%) KSHV+ cell concentrations when diagnosing pseudo-biopsy samples by smartphone image. Using histology, we confirm that our prepared pseudo-biopsies contain similar KSHV+ cell concentrations as human biopsies positive for KS. Through our testing of samples derived from human cell lines, we validate KS-Detect as a viable, portable KS diagnostic tool, and we identify critical engineering considerations for future solar-thermal PCR devices. PMID:26799834

  5. Improving early detection of childhood depression in mental health care: the Children׳s Depression Screener (ChilD-S).

    PubMed

    Allgaier, Antje-Kathrin; Krick, Kathrin; Opitz, Ansgar; Saravo, Barbara; Romanos, Marcel; Schulte-Körne, Gerd

    2014-07-30

    Diagnosing childhood depression can pose a challenge, even for mental health specialists. Screening tools can aid clinicians within the initial step of the diagnostic process. For the first time, the Children׳s Depression Screener (ChilD-S) is validated in a mental health setting as a novel field of application beyond the previously examined pediatric setting. Based on a structured interview, DSM-IV-TR diagnoses of depression were made for 79 psychiatric patients aged 9-12, serving as the gold standard for validation. For assessing criterion validity, receiver operating characteristic (ROC) curves were calculated. Point prevalence of major depression and dysthymia was 28%. Diagnostic accuracy in terms of the area under the ROC curve was high (0.97). At the optimal cut-off point ≥12 according to the Youden׳s index, sensitivity was 0.91 and specificity was 0.81. The findings suggest that the ChilD-S is not only a valid screening instrument for childhood depression in pediatric care but also in mental health settings. As a brief tool it can easily be implemented into daily clinical practice of mental health professionals facilitating the diagnostic process, especially in case of comorbid depression. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. Our experiences with the use of atopy patch test in the diagnosis of cow's milk hypersensitivity.

    PubMed

    Pustisek, Nives; Jaklin-Kekez, Alemka; Frkanec, Ruza; Sikanić-Dugić, Nives; Misak, Zrinjka; Jadresin, Oleg; Kolacek, Sanja

    2010-01-01

    Atopy patch test has been recognized as a diagnostic tool for the verification of food allergies in infants and small children suffering from atopic dermatitis. The test also has a role in the diagnosis of food allergies characterized by clinical signs associated with the digestive system. Yet, in spite of numerous studies, the test itself has hitherto not been standardized. Our study enlisted 151 children less than two years of age, who exhibited suspect skin and/or gastrointestinal manifestations of food allergy to cow's milk, and in whom tests failed to prove early type of allergic reaction. Atopy patch test was positive in 28% of the children with atopic dermatitis, 43% of the children with suspect gastrointestinal manifestation and 32% of the children with skin and gastrointestinal manifestations of food allergy. In our experience, atopy patch test is an excellent addition to the hitherto used tests for the diagnosis of food allergies. It targets specifically delayed type hypersensitivity reactions, which are difficult to confirm with other diagnostic tools. It is furthermore simple to perform, noninvasive and produces a minimum of undesired side effects. For these reasons, it should become part of the routine diagnostic toolset for food allergies to cow's milk in infants and children, and applied before a food challenge test.

  7. Histology Verification Demonstrates That Biospectroscopy Analysis of Cervical Cytology Identifies Underlying Disease More Accurately than Conventional Screening: Removing the Confounder of Discordance

    PubMed Central

    Gajjar, Ketan; Ahmadzai, Abdullah A.; Valasoulis, George; Trevisan, Júlio; Founta, Christina; Nasioutziki, Maria; Loufopoulos, Aristotelis; Kyrgiou, Maria; Stasinou, Sofia Melina; Karakitsos, Petros; Paraskevaidis, Evangelos; Da Gama-Rose, Bianca; Martin-Hirsch, Pierre L.; Martin, Francis L.

    2014-01-01

    Background Subjective visual assessment of cervical cytology is flawed, and this can manifest itself by inter- and intra-observer variability resulting ultimately in the degree of discordance in the grading categorisation of samples in screening vs. representative histology. Biospectroscopy methods have been suggested as sensor-based tools that can deliver objective assessments of cytology. However, studies to date have been apparently flawed by a corresponding lack of diagnostic efficiency when samples have previously been classed using cytology screening. This raises the question as to whether categorisation of cervical cytology based on imperfect conventional screening reduces the diagnostic accuracy of biospectroscopy approaches; are these latter methods more accurate and diagnose underlying disease? The purpose of this study was to compare the objective accuracy of infrared (IR) spectroscopy of cervical cytology samples using conventional cytology vs. histology-based categorisation. Methods Within a typical clinical setting, a total of n = 322 liquid-based cytology samples were collected immediately before biopsy. Of these, it was possible to acquire subsequent histology for n = 154. Cytology samples were categorised according to conventional screening methods and subsequently interrogated employing attenuated total reflection Fourier-transform IR (ATR-FTIR) spectroscopy. IR spectra were pre-processed and analysed using linear discriminant analysis. Dunn’s test was applied to identify the differences in spectra. Within the diagnostic categories, histology allowed us to determine the comparative efficiency of conventional screening vs. biospectroscopy to correctly identify either true atypia or underlying disease. Results Conventional cytology-based screening results in poor sensitivity and specificity. IR spectra derived from cervical cytology do not appear to discriminate in a diagnostic fashion when categories were based on conventional screening. Scores plots of IR spectra exhibit marked crossover of spectral points between different cytological categories. Although, significant differences between spectral bands in different categories are noted, crossover samples point to the potential for poor specificity and hampers the development of biospectroscopy as a diagnostic tool. However, when histology-based categories are used to conduct analyses, the scores plot of IR spectra exhibit markedly better segregation. Conclusions Histology demonstrates that ATR-FTIR spectroscopy of liquid-based cytology identifies the presence of underlying atypia or disease missed in conventional cytology screening. This study points to an urgent need for a future biospectroscopy study where categories are based on such histology. It will allow for the validation of this approach as a screening tool. PMID:24404130

  8. Diagnostic accuracy of metronome-paced tachypnea to detect dynamic hyperinflation.

    PubMed

    Lahaije, Anke J M C; Willems, Laura M; van Hees, Hieronymus W H; Dekhuijzen, P N Richard; van Helvoort, Hanneke A C; Heijdra, Yvonne F

    2013-01-01

    This prospective study was carried out to investigate if metronome-paced tachypnea (MPT) can serve as an accurate diagnostic tool to identify patients with chronic obstructive pulmonary disease (COPD) who are susceptible to develop dynamic hyperinflation during exercise. Commonly, this is assessed by measuring change in inspiratory capacity (IC) during cardiopulmonary exercise testing (CPET), which, however, is complex and laborious. Fifty-three patients with COPD (FEV(1) 58 ± 22%pred) and 20 age-matched healthy subjects were characterized by lung function testing and performed CPET (reference standard) and MPT. The repeatability coefficient of IC (10·2%) was used as cut-off to classify subjects as hyperinflators during CPET. Subsequently, dynamic hyperinflation was measured after MPT. With receiver operating characteristic analysis, the optimal cut-off for MPT-induced dynamic hyperinflation was determined and sensitivity and specificity of MPT to identify hyperinflators were evaluated. With 10·2% decrease in IC as cut-off for CPET-induced dynamic hyperinflation, the optimal cut-off for MPT was 11·1% decrease in IC. Using these cut-offs, MPT had a sensitivity of 85% and specificity of 85% to identify the subjects who hyperinflated during CPET. The MPT test shows good overall accuracy to identify subjects who are susceptible to develop dynamic hyperinflation during CPET. Before considering the use of MPT as a screening tool for dynamic hyperinflation in COPD, sensitivity and specificity need further evaluation. © 2012 The Authors Clinical Physiology and Functional Imaging © 2012 Scandinavian Society of Clinical Physiology and Nuclear Medicine.

  9. Molecular markers and new diagnostic methods to differentiate malignant from benign mesothelial pleural proliferations: a literature review.

    PubMed

    Bruno, Rossella; Alì, Greta; Fontanini, Gabriella

    2018-01-01

    Malignant pleural mesothelioma (MPM) is an aggressive tumor associated with asbestos exposure. Histopathological analysis of pleural tissues is the gold standard for diagnosis; however, it can be difficult to differentiate malignant from benign pleural lesions. The purpose of this review is to describe the most important biomarkers and new diagnostic tools suggested for this differential diagnosis. There are many studies concerning the separation between MPM and benign pleural proliferations from both pleural tissues or effusions; most of them are based on the evaluation of one or few biomarkers by immunohistochemistry (IHC) or enzyme-linked immunosorbent assays (ELISAs), whereas others focused on the identification of MPM signatures given by microRNA (miRNA) or gene expression profiles as well as on the combination of molecular data and classification algorithms. None of the reported biomarkers showed adequate diagnostic accuracy, except for p16 [evaluated by fluorescent in situ hybridization (FISH)] and BAP1 (evaluated by IHC), both biomarkers are recommended by the International Mesothelioma Interest Group guidelines for histological and cytological diagnosis. BAP1 and p16 showed a specificity of 100% in discerning malignant from benign lesions because they are exclusively unexpressed or deleted in MPM. However, their sensitivity, even when used together, is not completely sufficient, and absence of their alterations cannot confirm the benign nature of the lesion. Recently, the availability of new techniques and increasing knowledge regarding MPM genetics led to the definition of some molecular panels, including genes or miRNAs specifically deregulated in MPM, that are extremely valuable for differential diagnosis. Moreover, the development of classification algorithms is facilitating the application of molecular data for clinical practice. Data regarding new diagnostic tools and MPM signatures are absolutely promising; however, before their application in clinical practice, a prospective validation is necessary, as these approaches could surely improve the differential diagnosis between malignant and benign pleural lesions.

  10. APRI test and hyaluronic acid as non-invasive diagnostic tools for post HCV liver fibrosis: Systematic review and meta-analysis.

    PubMed

    El Serafy, Magdy Amin; Kassem, Abdel Meguid; Omar, Heba; Mahfouz, Mohammad Shaaban; El Said El Raziky, Maissa

    2017-06-01

    Hepatitis C virus (HCV) accounts for a sizable proportion of chronic liver disease cases and represents the most common indication for liver transplantation. Precise diagnosis of hepatic fibrosis stage is considered a funnel-neck in proper management and follow-up of HCV-infected patients. Given the possible complications of liver biopsy, a non-invasive method for assessing hepatic fibrosis is needed. This study aimed to evaluate the diagnostic accuracy of APRI and hyaluronic acid as non-invasive diagnostic assessment tools for post HCV liver fibrosis. Systematic literature searching identified studies performed on Egyptian territory to evaluate APRI and hyaluronic acid as non-invasive tests of fibrosis and using liver biopsy as the reference standard. Meta-analysis was performed for areas with an adequate number of publications. Validation of meta- analysis on APRI was done on a subset of 150 treatment-naïve post-hepatitis C patients. Both APRI and hyaluronic acid have superior predictive power for hepatic cirrhosis (F4) than for significant fibrosis (F2-F3). The pooled estimate for sensitivities and specificities of APRI and hyaluronic acid to diagnose F4 were (84% and 82%) and (83% and 89%) respectively. In the subgroup of treatment naïve post-hepatitis C patients, APRI had higher diagnostic performance to diagnose liver cirrhosis with 93.8% sensitivity and 72.4% specificity (AUC; 0.908, 95%CI; 0.851-0.965, p-value; <0.001) compared to its accuracy to diagnose significant hepatic fibrosis with 65.1% sensitivity and 77.8% (AUC; 0.685, 95% CI; 0.59-0.78, p-value; 0.001). APRI score and hyaluronic acid levels are simple and reliable non-invasive markers to detect advanced fibrosis among post-hepatitis C patients. Copyright © 2017 Pan-Arab Association of Gastroenterology. Published by Elsevier B.V. All rights reserved.

  11. The Development of an Open-Ended Drawing Tool: An Alternative Diagnostic Tool for Assessing Students' Understanding of the Particulate Nature of Matter

    ERIC Educational Resources Information Center

    Nyachwaya, James M.; Mohamed, Abdi-Rizak; Roehrig, Gillian H.; Wood, Nathan B.; Kern, Anne L.; Schneider, Jamie L.

    2011-01-01

    Many studies in the chemical education literature report students' alternative conceptions in chemistry and the difficulty they present for future learning. In this paper, we review existing diagnostic tools used to uncover students' alternative conceptions in chemistry and suggest that there are two fundamental issues with such instruments,…

  12. Phytophthora database 2.0: update and future direction.

    PubMed

    Park, Bongsoo; Martin, Frank; Geiser, David M; Kim, Hye-Seon; Mansfield, Michele A; Nikolaeva, Ekaterina; Park, Sook-Young; Coffey, Michael D; Russo, Joseph; Kim, Seong H; Balci, Yilmaz; Abad, Gloria; Burgess, Treena; Grünwald, Niklaus J; Cheong, Kyeongchae; Choi, Jaeyoung; Lee, Yong-Hwan; Kang, Seogchan

    2013-12-01

    The online community resource Phytophthora database (PD) was developed to support accurate and rapid identification of Phytophthora and to help characterize and catalog the diversity and evolutionary relationships within the genus. Since its release in 2008, the sequence database has grown to cover 1 to 12 loci for ≈2,600 isolates (representing 138 described and provisional species). Sequences of multiple mitochondrial loci were added to complement nuclear loci-based phylogenetic analyses and diagnostic tool development. Key characteristics of most newly described and provisional species have been summarized. Other additions to improve the PD functionality include: (i) geographic information system tools that enable users to visualize the geographic origins of chosen isolates on a global-scale map, (ii) a tool for comparing genetic similarity between isolates via microsatellite markers to support population genetic studies, (iii) a comprehensive review of molecular diagnostics tools and relevant references, (iv) sequence alignments used to develop polymerase chain reaction-based diagnostics tools to support their utilization and new diagnostic tool development, and (v) an online community forum for sharing and preserving experience and knowledge accumulated in the global Phytophthora community. Here we present how these improvements can support users and discuss the PD's future direction.

  13. Non-specific gastrointestinal features: Could it be Fabry disease?

    PubMed

    Hilz, Max J; Arbustini, Eloisa; Dagna, Lorenzo; Gasbarrini, Antonio; Goizet, Cyril; Lacombe, Didier; Liguori, Rocco; Manna, Raffaele; Politei, Juan; Spada, Marco; Burlina, Alessandro

    2018-05-01

    Non-specific gastrointestinal symptoms, including pain, diarrhoea, nausea, and vomiting, can be the first symptoms of Fabry disease. They may suggest more common disorders, e.g. irritable bowel syndrome or inflammatory bowel disease. The confounding clinical presentation and rarity of Fabry disease often cause long diagnostic delays and multiple misdiagnoses. Therefore, specialists involved in the clinical evaluation of non-specific upper and lower gastrointestinal symptoms should recognize Fabry disease as a possible cause of the symptoms, and should consider Fabry disease as a possible differential diagnosis. When symptoms or family history suggest Fabry disease, in men, low alpha-galactosidase A enzyme levels, and in women, specific Fabry mutations confirm the diagnosis. In addition to symptomatic treatments, disease-specific enzyme replacement therapy with recombinant human alpha-galactosidase A enzyme or chaperone therapy (migalastat) in patients with amenable mutations can improve the disease, including gastrointestinal symptoms, and should be initiated as early as possible after Fabry disease has been confirmed; starting enzyme replacement therapy at as young an age as possible after diagnosis improves long-term clinical outcomes. Improved diagnostic tools, such as a modified gastrointestinal symptom rating scale, may facilitate diagnosing Fabry disease in patients with gastrointestinal symptoms of unknown cause and thus assure timely initiation of disease-specific treatment. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. Using Performance Tools to Support Experiments in HPC Resilience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Naughton, III, Thomas J; Boehm, Swen; Engelmann, Christian

    2014-01-01

    The high performance computing (HPC) community is working to address fault tolerance and resilience concerns for current and future large scale computing platforms. This is driving enhancements in the programming environ- ments, specifically research on enhancing message passing libraries to support fault tolerant computing capabilities. The community has also recognized that tools for resilience experimentation are greatly lacking. However, we argue that there are several parallels between performance tools and resilience tools . As such, we believe the rich set of HPC performance-focused tools can be extended (repurposed) to benefit the resilience community. In this paper, we describe the initialmore » motivation to leverage standard HPC per- formance analysis techniques to aid in developing diagnostic tools to assist fault tolerance experiments for HPC applications. These diagnosis procedures help to provide context for the system when the errors (failures) occurred. We describe our initial work in leveraging an MPI performance trace tool to assist in provid- ing global context during fault injection experiments. Such tools will assist the HPC resilience community as they extend existing and new application codes to support fault tolerances.« less

  15. A computer-aided ECG diagnostic tool.

    PubMed

    Oweis, Rami; Hijazi, Lily

    2006-03-01

    Jordan lacks companies that provide local medical facilities with products that are of help in daily performed medical procedures. Because of this, the country imports most of these expensive products. Consequently, a local interest in producing such products has emerged and resulted in serious research efforts in this area. The main goal of this paper is to provide local (the north of Jordan) clinics with a computer-aided electrocardiogram (ECG) diagnostic tool in an attempt to reduce time and work demands for busy physicians especially in areas where only one general medicine doctor is employed and a bulk of cases are to be diagnosed. The tool was designed to help in detecting heart defects such as arrhythmias and heart blocks using ECG signal analysis depending on the time-domain representation, the frequency-domain spectrum, and the relationship between them. The application studied here represents a state of the art ECG diagnostic tool that was designed, implemented, and tested in Jordan to serve wide spectrum of population who are from poor families. The results of applying the tool on randomly selected representative sample showed about 99% matching with those results obtained at specialized medical facilities. Costs, ease of interface, and accuracy indicated the usefulness of the tool and its use as an assisting diagnostic tool.

  16. Molecular Classifiers for Acute Kidney Transplant Rejection in Peripheral Blood by Whole Genome Gene Expression Profiling

    PubMed Central

    Kurian, S. M.; Williams, A. N.; Gelbart, T.; Campbell, D.; Mondala, T. S.; Head, S. R.; Horvath, S.; Gaber, L.; Thompson, R.; Whisenant, T.; Lin, W.; Langfelder, P.; Robison, E. H.; Schaffer, R. L.; Fisher, J. S.; Friedewald, J.; Flechner, S. M.; Chan, L. K.; Wiseman, A. C.; Shidban, H.; Mendez, R.; Heilman, R.; Abecassis, M. M.; Marsh, C. L.; Salomon, D. R.

    2015-01-01

    There are no minimally invasive diagnostic metrics for acute kidney transplant rejection (AR), especially in the setting of the common confounding diagnosis, acute dysfunction with no rejection (ADNR). Thus, though kidney transplant biopsies remain the gold standard, they are invasive, have substantial risks, sampling error issues and significant costs and are not suitable for serial monitoring. Global gene expression profiles of 148 peripheral blood samples from transplant patients with excellent function and normal histology (TX; n = 46), AR (n = 63) and ADNR (n = 39), from two independent cohorts were analyzed with DNA microarrays. We applied a new normalization tool, frozen robust multi-array analysis, particularly suitable for clinical diagnostics, multiple prediction tools to discover, refine and validate robust molecular classifiers and we tested a novel one-by-one analysis strategy to model the real clinical application of this test. Multiple three-way classifier tools identified 200 highest value probesets with sensitivity, specificity, positive predictive value, negative predictive value and area under the curve for the validation cohort ranging from 82% to 100%, 76% to 95%, 76% to 95%, 79% to 100%, 84% to 100% and 0.817 to 0.968, respectively. We conclude that peripheral blood gene expression profiling can be used as a minimally invasive tool to accurately reveal TX, AR and ADNR in the setting of acute kidney transplant dysfunction. PMID:24725967

  17. Characterization and identification of proteases secreted by Aspergillus fumigatus using free flow electrophoresis and MS.

    PubMed

    Neustadt, Madlen; Costina, Victor; Kupfahl, Claudio; Buchheidt, Dieter; Eckerskorn, Christoph; Neumaier, Michael; Findeisen, Peter

    2009-06-01

    Early diagnosis of life-threatening invasive aspergillosis in neutropenic patients remains challenging because current laboratory methods have limited diagnostic sensitivity and/or specificity. Aspergillus species are known to secrete various pathogenetically relevant proteases and the monitoring of their protease activity in serum specimens might serve as a new diagnostic approach.For the characterization and identification of secreted proteases, the culture supernatant of Aspergillus fumigatus was fractionated using free flow electrophoresis (Becton Dickinson). Protease activity of separated fractions was measured using fluorescently labeled reporter peptides. Fractions were also co-incubated in parallel with various protease inhibitors that specifically inhibit a distinct class of proteases e.g. metallo- or cysteine-proteases. Those fractions with high protease activity were further subjected to LC-MS/MS analysis for protease identification. The highest protease activity was measured in fractions with an acidic pH range. The results of the 'inhibitor-panel' gave a clear indication that it is mainly metallo- and serine-proteases that are involved in the degradation of reporter peptides. Furthermore, several proteases were identified that facilitate the optimization of reporter peptides for functional protease profiling as a diagnostic tool for invasive aspergillosis.

  18. Advances in diagnosis and treatment of latent tuberculosis infection.

    PubMed

    Chapman, Helena J; Lauzardo, Michael

    2014-01-01

    In the United States, latent tuberculosis infection (LTBI) affects between 10 and 15 million people, of whom 10% may develop active tuberculosis disease. People at increased risk for tuberculosis reactivation include recent immigrants from countries with a high incidence of tuberculosis, children younger than age 5, people who have been infected with Mycobacterium tuberculosis within the past 2 years, or people with immunosuppression for a variety of reasons. Appropriate diagnosis and treatment of LTBI are critical for controlling and eventually eliminating tuberculosis as a public health problem. Although the tuberculin skin test is the traditional diagnostic measure for LTBI, reduced specificity has promoted the development and utilization of the interferon-γ release assays as an in vitro blood test with specific antigens to M. tuberculosis (QuantiFERON-TB Gold In-Tube test and the T.SPOT-TB test are commercially available). Despite the rise of the new diagnostic tests, however, there is still no gold standard for diagnosing LTBI, and epidemiologic risks and comorbidities need to be taken into account before initiating therapy. Current diagnostic tests combined with recommended treatment regimens are valuable tools that, when used correctly, promise to hurry the elimination of tuberculosis. © Copyright 2014 by the American Board of Family Medicine.

  19. Visualizing vascular structures in virtual environments

    NASA Astrophysics Data System (ADS)

    Wischgoll, Thomas

    2013-01-01

    In order to learn more about the cause of coronary heart diseases and develop diagnostic tools, the extraction and visualization of vascular structures from volumetric scans for further analysis is an important step. By determining a geometric representation of the vasculature, the geometry can be inspected and additional quantitative data calculated and incorporated into the visualization of the vasculature. To provide a more user-friendly visualization tool, virtual environment paradigms can be utilized. This paper describes techniques for interactive rendering of large-scale vascular structures within virtual environments. This can be applied to almost any virtual environment configuration, such as CAVE-type displays. Specifically, the tools presented in this paper were tested on a Barco I-Space and a large 62x108 inch passive projection screen with a Kinect sensor for user tracking.

  20. Critical comparison of diffuse reflectance spectroscopy and colorimetry as dermatological diagnostic tools for acanthosis nigricans: a chemometric approach

    PubMed Central

    Devpura, Suneetha; Pattamadilok, Bensachee; Syed, Zain U.; Vemulapalli, Pranita; Henderson, Marsha; Rehse, Steven J.; Hamzavi, Iltefat; Lim, Henry W.; Naik, Ratna

    2011-01-01

    Quantification of skin changes due to acanthosis nigricans (AN), a disorder common among insulin-resistant diabetic and obese individuals, was investigated using two optical techniques: diffuse reflectance spectroscopy (DRS) and colorimetry. Measurements were obtained from AN lesions on the neck and two control sites of eight AN patients. A principal component/discriminant function analysis successfully differentiated between AN lesion and normal skin with 87.7% sensitivity and 94.8% specificity in DRS measurements and 97.2% sensitivity and 96.4% specificity in colorimetry measurements. PMID:21698027

  1. Taenia asiatica: the most neglected human Taenia and the possibility of cysticercosis.

    PubMed

    Galán-Puchades, M Teresa; Fuentes, Mario V

    2013-02-01

    Not only Taenia solium and Taenia saginata, but also Taenia asiatica infects humans. The last species is not included in the evaluation of the specificity of the immunodiagnostic techniques for taeniasis/cysticercosis. There is currently no specific immunodiagnostic method for T. asiatica available. Therefore, due to the fact that molecular techniques (the only tool to distinguish the 3 Taenia species) are normally not employed in routine diagnostic methods, the 2 questions concerning T. asiatica (its definite geographic distribution and its ability to cause human cysticercosis), remain open, turning T. asiatica into the most neglected agent of human taeniasis-cysticercosis.

  2. Bacterial clonal diagnostics as a tool for evidence-based empiric antibiotic selection

    PubMed Central

    Tchesnokova, Veronika; Avagyan, Hovhannes; Rechkina, Elena; Chan, Diana; Muradova, Mariya; Haile, Helen Ghirmai; Radey, Matthew; Weissman, Scott; Riddell, Kim; Scholes, Delia; Johnson, James R.

    2017-01-01

    Despite the known clonal distribution of antibiotic resistance in many bacteria, empiric (pre-culture) antibiotic selection still relies heavily on species-level cumulative antibiograms, resulting in overuse of broad-spectrum agents and excessive antibiotic/pathogen mismatch. Urinary tract infections (UTIs), which account for a large share of antibiotic use, are caused predominantly by Escherichia coli, a highly clonal pathogen. In an observational clinical cohort study of urgent care patients with suspected UTI, we assessed the potential for E. coli clonal-level antibiograms to improve empiric antibiotic selection. A novel PCR-based clonotyping assay was applied to fresh urine samples to rapidly detect E. coli and the urine strain's clonotype. Based on a database of clonotype-specific antibiograms, the acceptability of various antibiotics for empiric therapy was inferred using a 20%, 10%, and 30% allowed resistance threshold. The test's performance characteristics and possible effects on prescribing were assessed. The rapid test identified E. coli clonotypes directly in patients’ urine within 25–35 minutes, with high specificity and sensitivity compared to culture. Antibiotic selection based on a clonotype-specific antibiogram could reduce the relative likelihood of antibiotic/pathogen mismatch by ≥ 60%. Compared to observed prescribing patterns, clonal diagnostics-guided antibiotic selection could safely double the use of trimethoprim/sulfamethoxazole and minimize fluoroquinolone use. In summary, a rapid clonotyping test showed promise for improving empiric antibiotic prescribing for E. coli UTI, including reversing preferential use of fluoroquinolones over trimethoprim/sulfamethoxazole. The clonal diagnostics approach merges epidemiologic surveillance, antimicrobial stewardship, and molecular diagnostics to bring evidence-based medicine directly to the point of care. PMID:28350870

  3. Bacterial clonal diagnostics as a tool for evidence-based empiric antibiotic selection.

    PubMed

    Tchesnokova, Veronika; Avagyan, Hovhannes; Rechkina, Elena; Chan, Diana; Muradova, Mariya; Haile, Helen Ghirmai; Radey, Matthew; Weissman, Scott; Riddell, Kim; Scholes, Delia; Johnson, James R; Sokurenko, Evgeni V

    2017-01-01

    Despite the known clonal distribution of antibiotic resistance in many bacteria, empiric (pre-culture) antibiotic selection still relies heavily on species-level cumulative antibiograms, resulting in overuse of broad-spectrum agents and excessive antibiotic/pathogen mismatch. Urinary tract infections (UTIs), which account for a large share of antibiotic use, are caused predominantly by Escherichia coli, a highly clonal pathogen. In an observational clinical cohort study of urgent care patients with suspected UTI, we assessed the potential for E. coli clonal-level antibiograms to improve empiric antibiotic selection. A novel PCR-based clonotyping assay was applied to fresh urine samples to rapidly detect E. coli and the urine strain's clonotype. Based on a database of clonotype-specific antibiograms, the acceptability of various antibiotics for empiric therapy was inferred using a 20%, 10%, and 30% allowed resistance threshold. The test's performance characteristics and possible effects on prescribing were assessed. The rapid test identified E. coli clonotypes directly in patients' urine within 25-35 minutes, with high specificity and sensitivity compared to culture. Antibiotic selection based on a clonotype-specific antibiogram could reduce the relative likelihood of antibiotic/pathogen mismatch by ≥ 60%. Compared to observed prescribing patterns, clonal diagnostics-guided antibiotic selection could safely double the use of trimethoprim/sulfamethoxazole and minimize fluoroquinolone use. In summary, a rapid clonotyping test showed promise for improving empiric antibiotic prescribing for E. coli UTI, including reversing preferential use of fluoroquinolones over trimethoprim/sulfamethoxazole. The clonal diagnostics approach merges epidemiologic surveillance, antimicrobial stewardship, and molecular diagnostics to bring evidence-based medicine directly to the point of care.

  4. Accuracy of dengue clinical diagnosis with and without NS1 antigen rapid test: Comparison between human and Bayesian network model decision.

    PubMed

    Sa-Ngamuang, Chaitawat; Haddawy, Peter; Luvira, Viravarn; Piyaphanee, Watcharapong; Iamsirithaworn, Sopon; Lawpoolsri, Saranath

    2018-06-18

    Differentiating dengue patients from other acute febrile illness patients is a great challenge among physicians. Several dengue diagnosis methods are recommended by WHO. The application of specific laboratory tests is still limited due to high cost, lack of equipment, and uncertain validity. Therefore, clinical diagnosis remains a common practice especially in resource limited settings. Bayesian networks have been shown to be a useful tool for diagnostic decision support. This study aimed to construct Bayesian network models using basic demographic, clinical, and laboratory profiles of acute febrile illness patients to diagnose dengue. Data of 397 acute undifferentiated febrile illness patients who visited the fever clinic of the Bangkok Hospital for Tropical Diseases, Thailand, were used for model construction and validation. The two best final models were selected: one with and one without NS1 rapid test result. The diagnostic accuracy of the models was compared with that of physicians on the same set of patients. The Bayesian network models provided good diagnostic accuracy of dengue infection, with ROC AUC of 0.80 and 0.75 for models with and without NS1 rapid test result, respectively. The models had approximately 80% specificity and 70% sensitivity, similar to the diagnostic accuracy of the hospital's fellows in infectious disease. Including information on NS1 rapid test improved the specificity, but reduced the sensitivity, both in model and physician diagnoses. The Bayesian network model developed in this study could be useful to assist physicians in diagnosing dengue, particularly in regions where experienced physicians and laboratory confirmation tests are limited.

  5. Quantifying motivational deficits and apathy: a review of the literature.

    PubMed

    Weiser, Mark; Garibaldi, George

    2015-08-01

    Varying definitions of apathy in the published literature and a lack of a consensus regarding diagnostic criteria make the identification and quantification of apathy difficult in both clinical trials and clinical practice. The Apathy Evaluation Scale was developed specifically to assess apathy, but variations in the threshold values defined for clinically significant apathy diminish its use as a screening tool in clinical trials, although it has demonstrated sensitivity to changes in treatment in a number of studies. The Neuropsychiatric Inventory contains an Apathy subscale, which has been used to identify clinical trial populations (with a consistent threshold value) and measure changes following treatment. Few of the other assessment tools currently used in patients with neuropsychiatric disorders are specific for apathy or explore it in any depth, most have not been validated in the general population, do not have cut-off points representing clinically significant apathy, and its changes over time and in response to treatment. Further research is required to address these issues in order to facilitate the quantification of apathy and its natural history. Such research should be conducted with the aim of developing new, specific tools for use across neuropsychiatric disorders. Copyright © 2015. Published by Elsevier B.V.

  6. Diagnostic performance of confocal laser endomicroscopy for optical diagnosis of gastric intestinal metaplasia: a meta-analysis.

    PubMed

    He, Xing-Kang; Liu, Dan; Sun, Lei-Min

    2016-09-05

    Gastric intestinal metaplasia (IM) is generally considered as a precancerous condition, a related risk factor for intestinal-type gastric cancer. However, an accurate endoscopic diagnosis of IM is a clinical challenge. Confocal Laser Endomicroscopy (CLE) is a newly technique that can provide real-time magnified images and visualize tissues at cellular or subcellular levels. The aim of this study is to clarify the diagnostic value of CLE in detection of IM in patients at high risk of gastric cancer. Systematic literature searches up to April 2015 in PubMed, Embase, Web of Science, Cochrane Library databases were conducted by two reviewers independently. The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool was applied to assess study quality and to reduce potential bias. A meta-analysis using Meta-Disc (version 1.4) and STATA software (version 13) was performed. A total of four studies enrolled 218 patients and 579 lesions were included in this meta-analysis. On per-lesion basis, the pooled sensitivity and specificity of CLE were 0.97(95 % confidence interval (CI) = 0.94-0.98) and 0.94 (95 % CI = 0.91-0.97) respectively. The pooled positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were 15.20 (95 % CI = 9.46-24.41) and 0.04 (95 % CI = 0.02-0.07) respectively. The pooled diagnostic odds ratio (DOR) was 479.59 (95 % CI = 205.64-1118.51) and summary receiver operating curve (SROC) area under the curve was 0.9884. There was no statistical significance of publication bias. CLE is a promising endoscopic tool in the detection of IM with the relatively high diagnostic value in patients at high risk of gastric cancer.

  7. Evaluation of serological diagnostic tests for typhoid fever in Papua New Guinea using a composite reference standard.

    PubMed

    Siba, Valentine; Horwood, Paul F; Vanuga, Kilagi; Wapling, Johanna; Sehuko, Rebecca; Siba, Peter M; Greenhill, Andrew R

    2012-11-01

    Typhoid fever remains a major global health problem. A major impediment to improving outcomes is the lack of appropriate diagnostic tools, which have not significantly improved in low-income settings for 100 years. We evaluated two commercially available rapid diagnostic tests (Tubex and TyphiDot), a prototype (TyphiRapid TR-02), and the commonly used single-serum Widal test in a previously reported high-burden area of Papua New Guinea. Samples were collected from 530 outpatients with axillary temperatures of ≥37.5°C, and analysis was conducted on all malaria-negative samples (n = 500). A composite reference standard of blood culture and PCR was used, by which 47 participants (9.4%) were considered typhoid fever positive. The sensitivity and specificity of the Tubex (51.1% and 88.3%, respectively) and TyphiDot (70.0% and 80.1%, respectively) tests were not high enough to warrant their ongoing use in this setting; however, the sensitivity and specificity for the TR-02 prototype were promising (89.4% and 85.0%, respectively). An axillary temperature of ≥38.5°C correlated with typhoid fever (P = 0.014). With an appropriate diagnostic test, conducting typhoid fever diagnosis only on patients with high-grade fever could dramatically decrease the costs associated with diagnosis while having no detrimental impact on the ability to accurately diagnose the illness.

  8. Surgical perspective of T1799A BRAF mutation diagnostic value in papillary thyroid carcinoma.

    PubMed

    Brahma, Bayu; Yulian, Erwin Danil; Ramli, Muchlis; Setianingsih, Iswari; Gautama, Walta; Brahma, Putri; Sastroasmoro, Sudigdo; Harimurti, Kuntjoro

    2013-01-01

    Throughout Indonesia, thyroid cancer is one of the ten commonest malignancies, with papillary thyroid carcinoma (PTC) in our hospital accounting for about 60% of all thyroid nodules. Although fine needle aspiration biopsy (FNAB) is the most reliable diagnostic tool, some nodules are diagnosed as indeterminate and second surgery is common for PTC. The aim of this study was to establish the diagnostic value and feasibility of testing the BRAF T1799A mutation on FNA specimens for improving PTC diagnosis. This prospective study enrolled 95 patients with thyroid nodules and future surgery planned. Results of mutational status were compared with surgical pathology diagnosis. Of the 70 cases included in the final analysis, 62.8% were PTC and the prevalence of BRAF mutation was 38.6%. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for BRAF mutation analysis were 36%, 100%, 100% and 48%, respectively. With other data findings, nodules with "onset less than 5 year" and "hard consistency" were proven as diagnostic determinants for BRAF mutation with a probability of 62.5%. This mutation was also a significant risk factor for extra-capsular extension. Molecular analysis of the BRAF T1799A mutation in FNAB specimens has high specificity and positive predictive value for PTC. It could be used in the selective patients with clinical characteristics to facilitate PTC diagnosis and for guidance regarding extent of thyroidectomy.

  9. Mass Spectrometry Based Ultrasensitive DNA Methylation Profiling Using Target Fragmentation Assay.

    PubMed

    Lin, Xiang-Cheng; Zhang, Ting; Liu, Lan; Tang, Hao; Yu, Ru-Qin; Jiang, Jian-Hui

    2016-01-19

    Efficient tools for profiling DNA methylation in specific genes are essential for epigenetics and clinical diagnostics. Current DNA methylation profiling techniques have been limited by inconvenient implementation, requirements of specific reagents, and inferior accuracy in quantifying methylation degree. We develop a novel mass spectrometry method, target fragmentation assay (TFA), which enable to profile methylation in specific sequences. This method combines selective capture of DNA target from restricted cleavage of genomic DNA using magnetic separation with MS detection of the nonenzymatic hydrolysates of target DNA. This method is shown to be highly sensitive with a detection limit as low as 0.056 amol, allowing direct profiling of methylation using genome DNA without preamplification. Moreover, this method offers a unique advantage in accurately determining DNA methylation level. The clinical applicability was demonstrated by DNA methylation analysis using prostate tissue samples, implying the potential of this method as a useful tool for DNA methylation profiling in early detection of related diseases.

  10. Diagnostic accuracy of quantitative real-time PCR assay versus clinical and Gram stain identification of bacterial vaginosis.

    PubMed

    Menard, J-P; Mazouni, C; Fenollar, F; Raoult, D; Boubli, L; Bretelle, F

    2010-12-01

    The purpose of this investigation was to determine the diagnostic accuracy of quantitative real-time polymerase chain reaction (PCR) assay in diagnosing bacterial vaginosis versus the standard methods, the Amsel criteria and the Nugent score. The Amsel criteria, the Nugent score, and results from the molecular tool were obtained independently from vaginal samples of 163 pregnant women who reported abnormal vaginal symptoms before 20 weeks gestation. To determine the performance of the molecular tool, we calculated the kappa value, sensitivity, specificity, and positive and negative predictive values. Either or both of the Amsel criteria (≥3 criteria) and the Nugent score (score ≥7) indicated that 25 women (15%) had bacterial vaginosis, and the remaining 138 women did not. DNA levels of Gardnerella vaginalis or Atopobium vaginae exceeded 10(9) copies/mL or 10(8) copies/mL, respectively, in 34 (21%) of the 163 samples. Complete agreement between both reference methods and high concentrations of G. vaginalis and A. vaginae was found in 94.5% of women (154/163 samples, kappa value = 0.81, 95% confidence interval 0.70-0.81). The nine samples with discordant results were categorized as intermediate flora by the Nugent score. The molecular tool predicted bacterial vaginosis with a sensitivity of 100%, a specificity of 93%, a positive predictive value of 73%, and a negative predictive value of 100%. The quantitative real-time PCR assay shows excellent agreement with the results of both reference methods for the diagnosis of bacterial vaginosis.

  11. A Novel Carbohydrate Antibody to GalNac1-3Gal and Its Application for Cancer Diagnostic and Prognosis | NCI Technology Transfer Center | TTC

    Cancer.gov

    The National Cancer Institute (NCI) seeks licensees for a monoclonal antibody specific to the GalNAc1-3Gal antigen that is present in human carcinomas. The antibody can be used as a research tool for a variety of purposes, including immunohistochemical staining of various human carcinomas. The antibody may also be useful as a prognostic marker for cervical cancer.

  12. Isolated gallbladder injury in a case of blunt abdominal trauma.

    PubMed

    Birn, Jeffrey; Jung, Melissa; Dearing, Mark

    2012-04-01

    The diagnosis of blunt injury to the gallbladder may constitute a significant challenge to the diagnostician. There is often a delay in presentation with non-specific clinical symptoms. In the absence of reliable clinical symptoms, diagnostic imaging becomes an invaluable tool in the rapid identification of gallbladder injury. We present a case of isolated gallbladder injury following blunt abdominal trauma which was diagnosed by computed tomography and subsequently confirmed by cholecystectomy.

  13. Escherichia coli: a brief review of diarrheagenic pathotypes and their role in diarrheal diseases in Iran

    PubMed Central

    Jafari, A; Aslani, MM; Bouzari, S

    2012-01-01

    Diarrheagenic Escherichia coli have developed different strategies for establishment of infection in their host. Understanding these pathogenic mechanisms has led to the development of specific diagnostic tools for identification and categorization of E. coli strains into different pathotypes. This review aims to provide an overview of the various categories of diarrheagenic Escherichia coli and the data obtained in Iran pertaining to these pathotypes. PMID:23066484

  14. The Environmental Qualification Specification as a Technical Management Tool,

    DTIC Science & Technology

    1981-11-01

    CommuentI The dwell test for fatigue of the isolation system in a container is intended to be an accelerated test, in order to save test time and...diagnostic purposes * Response computation is not the only possible design approach. In the development of control system or servomechanism theory , emphasis...seldom aborts a mission in the same way as a complete failure of any function, and properly influences system effectiveness through a different type of

  15. Surprisal analysis of Glioblastoma Multiform (GBM) microRNA dynamics unveils tumor specific phenotype.

    PubMed

    Zadran, Sohila; Remacle, Francoise; Levine, Raphael

    2014-01-01

    Gliomablastoma multiform (GBM) is the most fatal form of all brain cancers in humans. Currently there are limited diagnostic tools for GBM detection. Here, we applied surprisal analysis, a theory grounded in thermodynamics, to unveil how biomolecule energetics, specifically a redistribution of free energy amongst microRNAs (miRNAs), results in a system deviating from a non-cancer state to the GBM cancer -specific phenotypic state. Utilizing global miRNA microarray expression data of normal and GBM patients tumors, surprisal analysis characterizes a miRNA system response capable of distinguishing GBM samples from normal tissue biopsy samples. We indicate that the miRNAs contributing to this system behavior is a disease phenotypic state specific to GBM and is therefore a unique GBM-specific thermodynamic signature. MiRNAs implicated in the regulation of stochastic signaling processes crucial in the hallmarks of human cancer, dominate this GBM-cancer phenotypic state. With this theory, we were able to distinguish with high fidelity GBM patients solely by monitoring the dynamics of miRNAs present in patients' biopsy samples. We anticipate that the GBM-specific thermodynamic signature will provide a critical translational tool in better characterizing cancer types and in the development of future therapeutics for GBM.

  16. Diagnostic Yield of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration

    PubMed Central

    2011-01-01

    Background: New transbronchial needle aspiration (TBNA) technologies have been developed, but their clinical effectiveness and determinants of diagnostic yield have not been quantified. Prospective data are needed to determine risk-adjusted diagnostic yield. Methods: We prospectively enrolled patients undergoing TBNA of mediastinal lymph nodes in the American College of Chest Physicians Quality Improvement Registry, Evaluation, and Education (AQuIRE) multicenter database and recorded clinical, procedural, and provider information. All clinical decisions, including type of TBNA used (conventional vs endobronchial ultrasound-guided), were made by the attending bronchoscopist. The primary outcome was obtaining a specific diagnosis. Results: We enrolled 891 patients at six hospitals. Most procedures (95%) were performed with ultrasound guidance. A specific diagnosis was made in 447 cases. Unadjusted diagnostic yields were 37% to 54% for different hospitals, with significant between-hospital heterogeneity (P = .0001). Diagnostic yield was associated with annual hospital TBNA volume (OR, 1.003; 95% CI, 1.000-1.006; P = .037), smoking (OR, 1.55; 95% CI, 1.02-2.34; P = .042), biopsy of more than two sites (OR, 0.57; 95% CI, 0.38-0.85; P = .015), lymph node size (reference > 1-2 cm, ≤ 1 cm: OR, 0.51; 95% CI, 0.34-0.77; P = .003; > 2-3 cm: OR, 2.49; 95% CI, 1.61-3.85; P < .001; and > 3 cm: OR, 3.61; 95% CI, 2.17-6.00; P < .001), and positive PET scan (OR, 3.12; 95% CI, 1.39-7.01; P = .018). Biopsy was performed on more and smaller nodes at high-volume hospitals (P < .0001). Conclusions: To our knowledge, this is the first bronchoscopy study of risk-adjusted diagnostic yields on a hospital-level basis. High-volume hospitals were associated with high diagnostic yields. This study also demonstrates the value of procedural registries as a quality improvement tool. A larger number and variety of participating hospitals is needed to verify these results and to further investigate other determinants of diagnostic yield. PMID:21659432

  17. Modeling companion diagnostics in economic evaluations of targeted oncology therapies: systematic review and methodological checklist.

    PubMed

    Doble, Brett; Tan, Marcus; Harris, Anthony; Lorgelly, Paula

    2015-02-01

    The successful use of a targeted therapy is intrinsically linked to the ability of a companion diagnostic to correctly identify patients most likely to benefit from treatment. The aim of this study was to review the characteristics of companion diagnostics that are of importance for inclusion in an economic evaluation. Approaches for including these characteristics in model-based economic evaluations are compared with the intent to describe best practice methods. Five databases and government agency websites were searched to identify model-based economic evaluations comparing a companion diagnostic and subsequent treatment strategy to another alternative treatment strategy with model parameters for the sensitivity and specificity of the companion diagnostic (primary synthesis). Economic evaluations that limited model parameters for the companion diagnostic to only its cost were also identified (secondary synthesis). Quality was assessed using the Quality of Health Economic Studies instrument. 30 studies were included in the review (primary synthesis n = 12; secondary synthesis n = 18). Incremental cost-effectiveness ratios may be lower when the only parameter for the companion diagnostic included in a model is the cost of testing. Incorporating the test's accuracy in addition to its cost may be a more appropriate methodological approach. Altering the prevalence of the genetic biomarker, specific population tested, type of test, test accuracy and timing/sequence of multiple tests can all impact overall model results. The impact of altering a test's threshold for positivity is unknown as it was not addressed in any of the included studies. Additional quality criteria as outlined in our methodological checklist should be considered due to the shortcomings of standard quality assessment tools in differentiating studies that incorporate important test-related characteristics and those that do not. There is a need to refine methods for incorporating the characteristics of companion diagnostics into model-based economic evaluations to ensure consistent and transparent reimbursement decisions are made.

  18. Development and potential applications of microarrays based on fluorescent nanocrystal-encoded beads for multiplexed cancer diagnostics

    NASA Astrophysics Data System (ADS)

    Brazhnik, Kristina; Grinevich, Regina; Efimov, Anton E.; Nabiev, Igor; Sukhanova, Alyona

    2014-05-01

    Advanced multiplexed assays have recently become an indispensable tool for clinical diagnostics. These techniques provide simultaneous quantitative determination of multiple biomolecules in a single sample quickly and accurately. The development of multiplex suspension arrays is currently of particular interest for clinical applications. Optical encoding of microparticles is the most available and easy-to-use technique. This technology uses fluorophores incorporated into microbeads to obtain individual optical codes. Fluorophore-encoded beads can be rapidly analyzed using classical flow cytometry or microfluidic techniques. We have developed a new generation of highly sensitive and specific diagnostic systems for detection of cancer antigens in human serum samples based on microbeads encoded with fluorescent quantum dots (QDs). The designed suspension microarray system was validated for quantitative detection of (1) free and total prostate specific antigen (PSA) in the serum of patients with prostate cancer and (2) carcinoembryonic antigen (CEA) and cancer antigen 15-3 (CA 15-3) in the serum of patients with breast cancer. The serum samples from healthy donors were used as a control. The antigen detection is based on the formation of an immune complex of a specific capture antibody (Ab), a target antigen (Ag), and a detector Ab on the surface of the encoded particles. The capture Ab is bound to the polymer shell of microbeads via an adapter molecule, for example, protein A. Protein A binds a monoclonal Ab in a highly oriented manner due to specific interaction with the Fc-region of the Ab molecule. Each antigen can be recognized and detected due to a specific microbead population carrying the unique fluorescent code. 100 and 231 serum samples from patients with different stages of prostate cancer and breast cancer, respectively, and those from healthy donors were examined using the designed suspension system. The data were validated by comparing with the results of the "gold standard" enzyme-linked immunosorbent assay (ELISA). They have shown that our approach is a good alternative to the diagnostics of cancer markers using conventional assays, especially in early diagnostic applications.

  19. Strategies for diagnosing leg oedema in primary care: a qualitative study of GPs' approaches.

    PubMed

    Diederich, Judith; Hartel, Simone; Baum, Erika; Bösner, Stefan

    2014-12-01

    The symptom leg oedema represents a broad range of possible underlying aetiologies. The background of leg oedema is multifactorial and usually the GP is the first contact point for patients presenting with this symptom. GPs rely on patient history and physical examination as their main diagnostic tools. To identify GPs' diagnostic approaches and heuristics in patients presenting with leg oedema. Interviews with 15 GPs (20-30 min) using a semi-structured interview-guideline were conducted. GPs described their individual diagnostic strategies concerning all patients presenting with leg oedema they had prospectively identified during the previous four weeks. Interviews were taped and transcribed verbatim. Qualitative analysis was conducted by two independent raters. GPs applied a variety of diagnostic approaches, which can be grouped in active and passive strategies. Active strategies comprised the use of decision rules and guidelines, Bayesian arguing, problem dichotomisation and discrepancy heuristics. Passive approaches included test of time, therapy as diagnosis, and taking patient assumptions into account. When dealing with leg oedema, GPs use prior information of individual patients in a specific way. There is a broad variety of diagnostic approaches that can be grouped in 'active' and 'passive' behaviour. Approaches mostly match with established diagnostic strategies in primary care.

  20. A Research Agenda for Helminth Diseases of Humans: Diagnostics for Control and Elimination Programmes

    PubMed Central

    McCarthy, James S.; Lustigman, Sara; Yang, Guo-Jing; Barakat, Rashida M.; García, Héctor H.; Sripa, Banchob; Willingham, Arve Lee; Prichard, Roger K.; Basáñez, María-Gloria

    2012-01-01

    Diagnostic tools appropriate for undertaking interventions to control helminth infections are key to their success. Many diagnostic tests for helminth infection have unsatisfactory performance characteristics and are not well suited for use in the parasite control programmes that are being increasingly implemented. Although the application of modern laboratory research techniques to improve diagnostics for helminth infection has resulted in some technical advances, uptake has not been uniform. Frequently, pilot or proof of concept studies of promising diagnostic technologies have not been followed by much needed product development, and in many settings diagnosis continues to rely on insensitive and unsatisfactory parasitological or serodiagnostic techniques. In contrast, PCR-based xenomonitoring of arthropod vectors, and use of parasite recombinant proteins as reagents for serodiagnostic tests, have resulted in critical advances in the control of specific helminth parasites. The Disease Reference Group on Helminths Infections (DRG4), established in 2009 by the Special Programme for Research and Training in Tropical Diseases (TDR) was given the mandate to review helminthiases research and identify research priorities and gaps. In this review, the diagnostic technologies relevant to control of helminth infections, either available or in development, are reviewed. Critical gaps are identified and opportunities to improve needed technologies are discussed. PMID:22545166

  1. In silico maturation of binding-specificity of DNA aptamers against Proteus mirabilis.

    PubMed

    Savory, Nasa; Lednor, Danielle; Tsukakoshi, Kaori; Abe, Koichi; Yoshida, Wataru; Ferri, Stefano; Jones, Brian V; Ikebukuro, Kazunori

    2013-10-01

    Proteus mirabilis is a prominent cause of catheter-associated urinary tract infections (CAUTIs) among patients undergoing long-term bladder catheterization. There are currently no effective means of preventing P. mirabilis infections, and strategies for prophylaxis and rapid early diagnosis are urgently required. Aptamers offer significant potential for development of countermeasures against P. mirabilis CAUTI and are an ideal class of molecules for the development of diagnostics and therapeutics. Here we demonstrate the application of Cell-SELEX to identify DNA aptamers that show high affinity for P. mirabilis. While the aptamers identified displayed high affinity for P. mirabilis cells in dot blotting assays, they also bound to other uropathogenic bacteria. To improve aptamer specificity for P. mirabilis, an in silico maturation (ISM) approach was employed. Two cycles of ISM allowed the identification of an aptamer showing 36% higher specificity, evaluated as a ratio of binding signal for P. mirabilis to that for Escherichia coli (also a cause of CAUTI and the most common urinary tract pathogen). Aptamers that specifically recognize P. mirabilis would have diagnostic and therapeutic values and constitute useful tools for studying membrane-associated proteins in this organism. Copyright © 2013 Wiley Periodicals, Inc.

  2. Use of a three-band HRP2/pLDH combination rapid diagnostic test increases diagnostic specificity for falciparum malaria in Ugandan children.

    PubMed

    Hawkes, Michael; Conroy, Andrea L; Opoka, Robert O; Namasopo, Sophie; Liles, W Conrad; John, Chandy C; Kain, Kevin C

    2014-02-01

    Rapid diagnostic tests (RDTs) for malaria provide a practical alternative to light microscopy for malaria diagnosis in resource-limited settings. Three-band RDTs incorporating two parasite antigens may have enhanced diagnostic specificity, relative to two-band RDTs with a single parasite antigen (typically histidine-rich protein 2 [HRP2]). Phase 1: 2,000 children, two months to five years of age, admitted to a referral hospital in Jinja, Uganda, with acute febrile illness were enrolled. A WHO highly rated three-band RDT was compared to light microscopy of thick peripheral blood films read by local expert microscopists.Phase 2: the three-band RDT was used as a screening tool for inclusion of patients in a clinical trial, and subjects with three positive RDT bands were tested by microscopy using blood samples drawn in parallel. Discordant results were adjudicated by PCR. Phase 1: 1,648 children had both a RDT and peripheral blood smear performed. The specificity of a RDT with all three bands positive was 82% (95% CI: 79-85%) compared to 62% (95% CI: 59-66%) for HRP2 alone. The sensitivity was 88% (95% CI: 85-89%) and 94% (95% CI: 92-95%) for three-band positive RDT and HRP2 antigen, respectively. 119 patients (7.2%) had a positive HRP2 band, but negative parasite lactate dehydrogenase (pLHD) band and negative peripheral smear, and 72 (61%) of these had received pre-treatment with anti-malarials, suggesting a false positive HRP2 result (p = 0.002).Phase 2: the positive predictive value (PPV) of the three-band RDT was 94% (95% CI 89%-97%) using microscopy as the reference standard. However, microscopy-discordant results were shown to be positive for P. falciparum by PCR in all cases, suggesting that the PPV was in fact higher. The pLDH antigen on three-band RDTs, used in combination with HRP2, provides added diagnostic specificity for malaria parasitaemia and may be useful to distinguish acute infection from recently treated infection. In situations where diagnostic specificity is desirable (e.g., for selection of malaria-infected participants in clinical trials), a three-band RDT should be considered in a sub-Saharan African setting.

  3. Structured illumination microscopy as a diagnostic tool for nephrotic disease

    NASA Astrophysics Data System (ADS)

    Nylk, Jonathan; Pullman, James M.; Campbell, Elaine C.; Gunn-Moore, Frank J.; Prystowsky, Michael B.; Dholakia, Kishan

    2017-02-01

    Nephrotic disease is a group of debilitating and sometimes lethal diseases affecting kidney function, specifically the loss of ability to retain vital proteins in the blood while smaller molecules are removed through filtration into the urine. Treatment routes are often dictated by microscopic analysis of kidney biopsies. Podocytes within the glomeruli of the kidney have many interdigitating projections (foot processes), which form the main filtration system. Nephrotic disease is characterised by the loss of this tightly interdigitating substructure and its observation by electron microscopy (EM) is necessitated as these structures are typically 250 500nm wide, with 40nm spacing. Diagnosis by EM is both expensive and time consuming; it can take up to one week to complete the preparation, imaging, and analysis of a single sample. We propose structured illumination microscopy (SIM) as an alternative, optical diagnostic tool. Our results show that SIM can resolve the structure of fluorescent probes tagged to podocin, a protein localised to the periphery of the podocyte foot processes. Three-dimensional podocin maps were acquired in healthy tissue and tissue from patients diagnosed with two different nephrotic disease states; minimal change disease and membranous nephropathy. These structures correlated well with EM images of the same structure. Preparation, imaging, and analysis could be achieved in several hours. Additionally, the volumetric information of the SIM images revealed morphological changes in disease states not observed by EM. This evidence supports the use of SIM as a diagnostic tool for nephrotic disease and can potentially reduce the time and cost per diagnosis.

  4. Point-of-care diagnostic assay for the detection of Zika virus using the recombinase polymerase amplification method.

    PubMed

    Vasileva Wand, Nadina I; Bonney, Laura C; Watson, Robert J; Graham, Victoria; Hewson, Roger

    2018-06-13

    The sudden and explosive expansion of Zika virus (ZIKV) from the African continent through Oceania and culminating in the outbreak in South America has highlighted the importance of new rapid point-of-care diagnostic tools for the control and prevention of transmission. ZIKV infection has devastating consequences, such as neurological congenital malformations in infants born to infected mothers and Guillain-Barré syndrome in adults. Additionally, its potential for transmission through vector bites, as well as from person to person through blood transfusions and sexual contact, are important considerations for prompt diagnosis. Recombinase polymerase amplification (RPA), an isothermal method, was developed as an alternative field-applicable assay to PCR. Here we report the development of a novel ZIKV real-time reverse transcriptase RPA (RT-RPA) assay capable of detecting a range of different ZIKV strains from a variety of geographical locations. The ZIKV RT-RPA was shown to be highly sensitive, being capable of detecting as few as five copies of target nucleic acid per reaction, and suitable for use with a battery-operated portable device. The ZIKV RT-RPA demonstrated 100 % specificity and 83 % sensitivity in clinical samples. Furthermore, we determined that the ZIKV RT-RPA is a versatile assay that can be applied to crude samples, such as saliva and serum, and can be used as a vector surveillance tool on crude mosquito homogenates. Therefore, the developed ZIKV RT-RPA is a useful diagnostic tool that can be transferred to a resource-limited location, eliminating the need for a specialized and sophisticated laboratory environment and highly trained staff.

  5. Diagnostics for Confounding of Time-varying and Other Joint Exposures.

    PubMed

    Jackson, John W

    2016-11-01

    The effects of joint exposures (or exposure regimes) include those of adhering to assigned treatment versus placebo in a randomized controlled trial, duration of exposure in a cohort study, interactions between exposures, and direct effects of exposure, among others. Unlike the setting of a single point exposure (e.g., propensity score matching), there are few tools to describe confounding for joint exposures or how well a method resolves it. Investigators need tools that describe confounding in ways that are conceptually grounded and intuitive for those who read, review, and use applied research to guide policy. We revisit the implications of exchangeability conditions that hold in sequentially randomized trials, and the bias structure that motivates the use of g-methods, such as marginal structural models. From these, we develop covariate balance diagnostics for joint exposures that can (1) describe time-varying confounding, (2) assess whether covariates are predicted by prior exposures given their past, the indication for g-methods, and (3) describe residual confounding after inverse probability weighting. For each diagnostic, we present time-specific metrics that encompass a wide class of joint exposures, including regimes of multivariate time-varying exposures in censored data, with multivariate point exposures as a special case. We outline how to estimate these directly or with regression and how to average them over person-time. Using a simulated example, we show how these metrics can be presented graphically. This conceptually grounded framework can potentially aid the transparent design, analysis, and reporting of studies that examine joint exposures. We provide easy-to-use tools to implement it.

  6. Evidence assessing the diagnostic performance of medical smartphone apps: a systematic review and exploratory meta-analysis.

    PubMed

    Buechi, Rahel; Faes, Livia; Bachmann, Lucas M; Thiel, Michael A; Bodmer, Nicolas S; Schmid, Martin K; Job, Oliver; Lienhard, Kenny R

    2017-12-14

    The number of mobile applications addressing health topics is increasing. Whether these apps underwent scientific evaluation is unclear. We comprehensively assessed papers investigating the diagnostic value of available diagnostic health applications using inbuilt smartphone sensors. Systematic Review-MEDLINE, Scopus, Web of Science inclusive Medical Informatics and Business Source Premier (by citation of reference) were searched from inception until 15 December 2016. Checking of reference lists of review articles and of included articles complemented electronic searches. We included all studies investigating a health application that used inbuilt sensors of a smartphone for diagnosis of disease. The methodological quality of 11 studies used in an exploratory meta-analysis was assessed with the Quality Assessment of Diagnostic Accuracy Studies 2 tool and the reporting quality with the 'STAndards for the Reporting of Diagnostic accuracy studies' (STARD) statement. Sensitivity and specificity of studies reporting two-by-two tables were calculated and summarised. We screened 3296 references for eligibility. Eleven studies, most of them assessing melanoma screening apps, reported 17 two-by-two tables. Quality assessment revealed high risk of bias in all studies. Included papers studied 1048 subjects (758 with the target conditions and 290 healthy volunteers). Overall, the summary estimate for sensitivity was 0.82 (95 % CI 0.56 to 0.94) and 0.89 (95 %CI 0.70 to 0.97) for specificity. The diagnostic evidence of available health apps on Apple's and Google's app stores is scarce. Consumers and healthcare professionals should be aware of this when using or recommending them. 42016033049. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Precision Oncology Medicine: The Clinical Relevance of Patient-Specific Biomarkers Used to Optimize Cancer Treatment.

    PubMed

    Schmidt, Keith T; Chau, Cindy H; Price, Douglas K; Figg, William D

    2016-12-01

    Precision medicine in oncology is the result of an increasing awareness of patient-specific clinical features coupled with the development of genomic-based diagnostics and targeted therapeutics. Companion diagnostics designed for specific drug-target pairs were the first to widely utilize clinically applicable tumor biomarkers (eg, HER2, EGFR), directing treatment for patients whose tumors exhibit a mutation susceptible to an FDA-approved targeted therapy (eg, trastuzumab, erlotinib). Clinically relevant germline mutations in drug-metabolizing enzymes and transporters (eg, TPMT, DPYD) have been shown to impact drug response, providing a rationale for individualized dosing to optimize treatment. The use of multigene expression-based assays to analyze an array of prognostic biomarkers has been shown to help direct treatment decisions, especially in breast cancer (eg, Oncotype DX). More recently, the use of next-generation sequencing to detect many potential "actionable" cancer molecular alterations is further shifting the 1 gene-1 drug paradigm toward a more comprehensive, multigene approach. Currently, many clinical trials (eg, NCI-MATCH, NCI-MPACT) are assessing novel diagnostic tools with a combination of different targeted therapeutics while also examining tumor biomarkers that were previously unexplored in a variety of cancer histologies. Results from ongoing trials such as the NCI-MATCH will help determine the clinical utility and future development of the precision-medicine approach. © 2016, The American College of Clinical Pharmacology.

  8. Clinical Diagnostic Utility of IP-10 and LAM Antigen Levels for the Diagnosis of Tuberculous Pleural Effusions in a High Burden Setting

    PubMed Central

    Dheda, Keertan; Van-Zyl Smit, Richard N.; Sechi, Leonardo A.; Badri, Motasim; Meldau, Richard; Symons, Gregory; Khalfey, Hoosein; Carr, Igshaan; Maredza, Alice; Dawson, Rodney; Wainright, Helen; Whitelaw, Andrew; Bateman, Eric D.; Zumla, Alimuddin

    2009-01-01

    Background Current tools for the diagnosis of tuberculosis pleural effusions are sub-optimal. Data about the value of new diagnostic technologies are limited, particularly, in high burden settings. Preliminary case control studies have identified IFN-γ-inducible-10kDa protein (IP-10) as a promising diagnostic marker; however, its diagnostic utility in a day-to-day clinical setting is unclear. Detection of LAM antigen has not previously been evaluated in pleural fluid. Methods We investigated the comparative diagnostic utility of established (adenosine deaminase [ADA]), more recent (standardized nucleic-acid-amplification-test [NAAT]) and newer technologies (a standardized LAM mycobacterial antigen-detection assay and IP-10 levels) for the evaluation of pleural effusions in 78 consecutively recruited South African tuberculosis suspects. All consenting participants underwent pleural biopsy unless contra-indicated or refused. The reference standard comprised culture positivity for M. tuberculosis or histology suggestive of tuberculosis. Principal Findings Of 74 evaluable subjects 48, 7 and 19 had definite, probable and non-TB, respectively. IP-10 levels were significantly higher in TB vs non-TB participants (p<0.0001). The respective outcomes [sensitivity, specificity, PPV, NPV %] for the different diagnostic modalities were: ADA at the 30 IU/L cut-point [96; 69; 90; 85], NAAT [6; 93; 67; 28], IP-10 at the 28,170 pg/ml ROC-derived cut-point [80; 82; 91; 64], and IP-10 at the 4035 pg/ml cut-point [100; 53; 83; 100]. Thus IP-10, using the ROC-derived cut-point, missed ∼20% of TB cases and mis-diagnosed ∼20% of non-TB cases. By contrast, when a lower cut-point was used a negative test excluded TB. The NAAT had a poor sensitivity but high specificity. LAM antigen-detection was not diagnostically useful. Conclusion Although IP-10, like ADA, has sub-optimal specificity, it may be a clinically useful rule-out test for tuberculous pleural effusions. Larger multi-centric studies are now required to confirm our findings. PMID:19277111

  9. A Comparative Analysis of the ADOS-G and ADOS-2 Algorithms: Preliminary Findings.

    PubMed

    Dorlack, Taylor P; Myers, Orrin B; Kodituwakku, Piyadasa W

    2018-06-01

    The Autism Diagnostic Observation Schedule (ADOS) is a widely utilized observational assessment tool for diagnosis of autism spectrum disorders. The original ADOS was succeeded by the ADOS-G with noted improvements. More recently, the ADOS-2 was introduced to further increase its diagnostic accuracy. Studies examining the validity of the ADOS have produced mixed findings, and pooled relationship trends between the algorithm versions are yet to be analyzed. The current review seeks to compare the relative merits of the ADOS-G and ADOS-2 algorithms, Modules 1-3. Eight studies met inclusion criteria for the review, and six were selected for paired comparisons of the sensitivity and specificity of the ADOS. Results indicate several contradictory findings, underscoring the importance of further study.

  10. American College of Foot and Ankle Surgeons Clinical Consensus Statement: Diagnosis and Treatment of Adult Acquired Infracalcaneal Heel Pain.

    PubMed

    Schneider, Harry P; Baca, John M; Carpenter, Brian B; Dayton, Paul D; Fleischer, Adam E; Sachs, Brett D

    Adult acquired inferior calcaneal heel pain is a common pathology seen in a foot and ankle practice. A literature review and expert panel discussion of the most common findings and treatment options are presented. Various diagnostic and treatment modalities are available to the practitioner. It is prudent to combine appropriate history and physical examination findings with patient-specific treatment modalities for optimum success. We present the most common diagnostic tools and treatment options, followed by a discussion of the appropriateness of each based on the published data and experience of the expert panel. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Challenges for allergy diagnosis in regions with complex pollen exposures.

    PubMed

    Barber, Domingo; Díaz-Perales, Araceli; Villalba, Mayte; Chivato, Tomas

    2015-02-01

    Over the past few decades, significant scientific progress has influenced clinical allergy practice. The biological standardization of extracts was followed by the massive identification and characterization of new allergens and their progressive use as diagnostic tools including allergen micro arrays that facilitate the simultaneous testing of more than 100 allergen components. Specific diagnosis is the basis of allergy practice and is always aiming to select the best therapeutic or avoidance intervention. As a consequence, redundant or irrelevant information might be adding unnecessary cost and complexity to daily clinical practice. A rational use of the different diagnostic alternatives would allow a significant improvement in the diagnosis and treatment of allergic patients, especially for those residing in complex pollen exposure areas.

  12. Machine Learning Approach to Extract Diagnostic and Prognostic Thresholds: Application in Prognosis of Cardiovascular Mortality

    PubMed Central

    Mena, Luis J.; Orozco, Eber E.; Felix, Vanessa G.; Ostos, Rodolfo; Melgarejo, Jesus; Maestre, Gladys E.

    2012-01-01

    Machine learning has become a powerful tool for analysing medical domains, assessing the importance of clinical parameters, and extracting medical knowledge for outcomes research. In this paper, we present a machine learning method for extracting diagnostic and prognostic thresholds, based on a symbolic classification algorithm called REMED. We evaluated the performance of our method by determining new prognostic thresholds for well-known and potential cardiovascular risk factors that are used to support medical decisions in the prognosis of fatal cardiovascular diseases. Our approach predicted 36% of cardiovascular deaths with 80% specificity and 75% general accuracy. The new method provides an innovative approach that might be useful to support decisions about medical diagnoses and prognoses. PMID:22924062

  13. Nucleic acid aptamers: research tools in disease diagnostics and therapeutics.

    PubMed

    Santosh, Baby; Yadava, Pramod K

    2014-01-01

    Aptamers are short sequences of nucleic acid (DNA or RNA) or peptide molecules which adopt a conformation and bind cognate ligands with high affinity and specificity in a manner akin to antibody-antigen interactions. It has been globally acknowledged that aptamers promise a plethora of diagnostic and therapeutic applications. Although use of nucleic acid aptamers as targeted therapeutics or mediators of targeted drug delivery is a relatively new avenue of research, one aptamer-based drug "Macugen" is FDA approved and a series of aptamer-based drugs are in clinical pipelines. The present review discusses the aspects of design, unique properties, applications, and development of different aptamers to aid in cancer diagnosis, prevention, and/or treatment under defined conditions.

  14. Sensitivity and specificity of the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) and the Intensive Care Delirium Screening Checklist (ICDSC) for detecting post-cardiac surgery delirium: A single-center study in Japan.

    PubMed

    Nishimura, Katsuji; Yokoyama, Kanako; Yamauchi, Noriko; Koizumi, Masako; Harasawa, Nozomi; Yasuda, Taeko; Mimura, Chizuru; Igita, Hazuki; Suzuki, Eriko; Uchiide, Yoko; Seino, Yusuke; Nomura, Minoru; Yamazaki, Kenji; Ishigooka, Jun

    2016-01-01

    To compare the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) and the Intensive Care Delirium Screening Checklist (ICDSC) for detecting post-cardiac surgery delirium. These tools have not been tested in a specialized cardio-surgical ICU. Sensitivities and specificities of each tool were assessed in a cardio-surgical ICU in Japan by two trained nurses independently. Results were compared with delirium diagnosed by psychiatrists using the Diagnostic and Statistical Manual of Mental Disorders, 4th Edition, Text Revision. There were 110 daily, paired assessments in 31 patients. The CAM-ICU showed 38% sensitivity and 100% specificity for both nurses. All 20 false-negative cases resulted from high scores in the auditory attention screening in CAM-ICU. The ICDSC showed 97% and 94% sensitivity, and 97% and 91% specificity for the two nurses (cutoff ≥4). In a Japanese cardio-surgical ICU, the ICDSC had a higher sensitivity than the CAM-ICU. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Diagnostic tools in Rhinology EAACI position paper

    PubMed Central

    2011-01-01

    This EAACI Task Force document aims at providing the readers with a comprehensive and complete overview of the currently available tools for diagnosis of nasal and sino-nasal disease. We have tried to logically order the different important issues related to history taking, clinical examination and additional investigative tools for evaluation of the severity of sinonasal disease into a consensus document. A panel of European experts in the field of Rhinology has contributed to this consensus document on Diagnostic Tools in Rhinology. PMID:22410181

  16. Comparison of four rapid diagnostic tests, ELISA, microscopy and PCR for the detection of Giardia lamblia, Cryptosporidium spp. and Entamoeba histolytica in feces.

    PubMed

    Van den Bossche, Dorien; Cnops, Lieselotte; Verschueren, Jacob; Van Esbroeck, Marjan

    2015-03-01

    Microscopy is the diagnostic reference standard for the detection of parasites, but it is labor-intensive and requires experience. Rapid diagnostic tests (RDTs) can provide an alternative to microscopy. RDTs from four different manufacturers were compared to enzyme-linked immunosorbent assay (ELISA), microscopy and/or parasite-specific real-time PCR: ImmunoCardSTAT!®CGE (Meridian Bioscience Inc., Cincinnati, Ohio, USA) (A), Crypto/Giardia Duo-Strip (Coris Bioconcepts, Gembloux, Belgium) (B), RIDA®QUICK Cryptosporidium/Giardia/Entamoeba Combi (R-BioPharm, Darmstadt, Germany) (C) and Giardia/Cryptosporidium Quik Chek (Techlab Inc., Blacksburg, Virginia, USA) (D). Thirty frozen samples were analyzed retrospectively. For Giardia lamblia (n=12) and Cryptosporidium (n=12) sensitivities ranged from 58% (B), over 83% (A, C) to 100% (D) and from 92% (B) to 100% (A, C, D), respectively. Specificity for both G. lamblia and Cryptosporidium was 100% for all RDT brands. Sensitivity for Entamoeba histolytica (n=5) was 100%, while specificity reached 80% (A) to 88% (C). In a prospective study, fresh samples were tested. For G. lamblia (n=30), sensitivity ranged from 66% (B), over 79% (A) and 83% (C) to 100% (D) and specificity varied between 94% (D) and 100% (A, B, C). For Cryptosporidium (n=3), sensitivity was 100% for all brands except (B) (67%) and specificities were 95% (A, B), 98% (C) and 100% (D). E. histolytica (n=1) was detected by both (A) and (C), while specificity was 81% and 87% respectively. RDTs can be a valuable tool when microscopic expertise is poor and in remote and outbreak settings where other techniques are often not available and rapid diagnosis is required. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Diagnostic performance of serological tests for swine brucellosis in the presence of false positive serological reactions.

    PubMed

    Dieste-Pérez, L; Blasco, J M; de Miguel, M J; Moriyón, I; Muñoz, P M

    2015-04-01

    Swine brucellosis caused by Brucella suis biovar 2 is an emerging disease in Europe. Currently used diagnostic tests for swine brucellosis detect antibodies to the O-polysaccharide (O-PS) of Brucella smooth lipopolysaccharide (S-LPS) but their specificity is compromised by false-positive serological reactions (FPSRs) when bacteria carrying cross-reacting O-PS infect pigs. FPSRs occur throughout Europe, and the only tool available for a specific B. suis diagnosis is the intradermal test with Brucella protein extracts free of O-PS or S-LPS. Using sera of 162 sows naturally infected by B. suis biovar 2, 406 brucellosis-free sows, and 218 pigs of brucellosis-free farms affected by FPSR, we assessed the diagnostic performance of an indirect ELISA with rough LPS (thus devoid of O-PS) and of gel immunodiffusion, counterimmunoelectrophoresis, latex agglutination and indirect ELISA with O-PS free proteins in comparison with several S-LPS tests (Rose Bengal, complement fixation, gel immunodiffusion and indirect ELISA). When adjusted to 100% specificity, the sensitivity of the rough LPS ELISA was very low (30%), and adoption of other cut-offs resulted in poor specificity/sensitivity ratios. Although their specificity was 100%, the sensitivity of protein tests (ELISA, latex agglutination, counterimmunoelectrophoresis, and gel immunodiffusion) was only moderate (45, 58, 61 and 63%, respectively). Among S-LPS tests, gel immunodiffusion was the only test showing acceptable sensitivity/specificity (68 and 100%, respectively). Despite these shortcomings, and when the purpose is to screen out FPSR at herd level, gel immunodiffusion tests may offer a technically simple and practical alternative to intradermal testing. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Molecular malaria diagnostics: A systematic review and meta-analysis.

    PubMed

    Roth, Johanna M; Korevaar, Daniël A; Leeflang, Mariska M G; Mens, Pètra F

    2016-01-01

    Accurate diagnosis of malaria is essential for identification and subsequent treatment of the disease. Currently, microscopy and rapid diagnostic tests are the most commonly used diagnostics, next to treatment based on clinical signs only. These tests are easy to deploy, but have a relatively high detection limit. With declining prevalence in many areas, there is an increasing need for more sensitive diagnostics. Molecular tools may be a suitable alternative, although costs and technical requirements currently hamper their implementation in resource limited settings. A range of (near) point-of-care diagnostics is therefore under development, including simplifications in sample preparation, amplification and/or read-out of the test. Accuracy data, in combination with technical characteristics, are essential in determining which molecular test, if any, would be the most promising to be deployed. This review presents a comprehensive overview of the currently available molecular malaria diagnostics, ranging from well-known tests to platforms in early stages of evaluation, and systematically evaluates their published accuracy. No important difference in accuracy was found between the most commonly used PCR-based assays (conventional, nested and real-time PCR), with most of them having high sensitivity and specificity, implying that there are no reasons other than practical ones to choose one technique over the other. Loop-mediated isothermal amplification and other (novel) diagnostics appear to be highly accurate as well, with some offering potential to be used in resource-limited settings.

  19. Identification of a new diagnostic antigen for glanders using immunoproteome analysis.

    PubMed

    Dohre, Sudhir K; Kamthan, Aayushi; Singh, Sandeep; Alam, Syed Imteyaz; Kumar, Subodh

    2017-08-01

    Glanders is a disease of horses, donkeys and mules. The causative agent Burkholderia mallei, is a biorisk group 3 pathogen and is also a biothreat agent. Simple and rapid diagnostic tool is essential for control of glanders. Using a proteomic approach and immunoblotting with equine sera, we identified 12 protein antigens that may have diagnostic potential. Various immunoreactive proteins e.g. GroEL, translation elongation factor Tu, elongation factor Ts, arginine deiminase, malate dehydrogenase, DNA directed RNA polymerase subunit alpha were identified on 2-dimentional immunoblots. One of these proteins, GroEL, was cloned and expressed in E. coli and purified using Ni-NTA affinity chromatography. The recombinant GroEL protein was evaluated in ELISA format on a panel of glanders positive (n=49) and negative (n=79) equine serum samples to determine its diagnostic potential. The developed ELISA had a sensitivity and specificity of 96 and 98.7% respectively. The results of this study highlight the potential of GroEL in serodiagnosis of glanders. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Advanced DNA-Based Point-of-Care Diagnostic Methods for Plant Diseases Detection.

    PubMed

    Lau, Han Yih; Botella, Jose R

    2017-01-01

    Diagnostic technologies for the detection of plant pathogens with point-of-care capability and high multiplexing ability are an essential tool in the fight to reduce the large agricultural production losses caused by plant diseases. The main desirable characteristics for such diagnostic assays are high specificity, sensitivity, reproducibility, quickness, cost efficiency and high-throughput multiplex detection capability. This article describes and discusses various DNA-based point-of care diagnostic methods for applications in plant disease detection. Polymerase chain reaction (PCR) is the most common DNA amplification technology used for detecting various plant and animal pathogens. However, subsequent to PCR based assays, several types of nucleic acid amplification technologies have been developed to achieve higher sensitivity, rapid detection as well as suitable for field applications such as loop-mediated isothermal amplification, helicase-dependent amplification, rolling circle amplification, recombinase polymerase amplification, and molecular inversion probe. The principle behind these technologies has been thoroughly discussed in several review papers; herein we emphasize the application of these technologies to detect plant pathogens by outlining the advantages and disadvantages of each technology in detail.

Top