Sagha Zadeh, Rana; Shepley, Mardelle M; Owora, Arthur Hamie; Dannenbaum, Martha C; Waggener, Laurie T; Chung, Susan Sung Eun
2018-05-01
To examine the importance of specific workplace environment characteristics for maximum health and performance, assigned by healthcare employees, and how they relate to the nature of their work. A cross-sectional mixed-method study was conducted with content analysis and robust regression models to examine the relationship between workplace environment characteristics and perceived importance in promoting health and performance. Our findings suggest that perceptions of key environment characteristics that safeguard health and performance in healthcare workplaces may vary by employee sex, setting, and nature of healthcare work involved. Theme and model descriptions of the influence of these factors on participant perceptions are provided. Employee feedback on workplace characteristics that impact health and performance could be instrumental in determining the priorities of workplace design.
Code of Federal Regulations, 2010 CFR
2010-01-01
... term consumer product means any article produced or distributed for sale to a consumer for the use... performance characteristic means a performance characteristic of a consumer product that can be measured in an objective manner with respect to a given consumer product. (g) The term Specification means a Performance...
Can Knowledge of the Characteristics of "High Performers" Be Generalised?
ERIC Educational Resources Information Center
McKenna, Stephen
2002-01-01
Two managers described as high performing constructed complexity maps of their organization/world. The maps suggested that high performance is socially constructed and negotiated in specific contexts and management competencies associated with it are context specific. Development of high performers thus requires personalized coaching more than…
Characterization of advanced electric propulsion systems
NASA Technical Reports Server (NTRS)
Ray, P. K.
1982-01-01
Characteristics of several advanced electric propulsion systems are evaluated and compared. The propulsion systems studied are mass driver, rail gun, MPD thruster, hydrogen free radical thruster and mercury electron bombardment ion engine. These are characterized by specific impulse, overall efficiency, input power, average thrust, power to average thrust ratio and average thrust to dry weight ratio. Several important physical characteristics such as dry system mass, accelerator length, bore size and current pulse requirement are also evaluated in appropriate cases. Only the ion engine can operate at a specific impulse beyond 2000 sec. Rail gun, MPD thruster and free radical thruster are currently characterized by low efficiencies. Mass drivers have the best performance characteristics in terms of overall efficiency, power to average thrust ratio and average thrust to dry weight ratio. But, they can only operate at low specific impulses due to large power requirements and are extremely long due to limitations of driving current. Mercury ion engines have the next best performance characteristics while operating at higher specific impulses. It is concluded that, overall, ion engines have somewhat better characteristics as compared to the other electric propulsion systems.
Development of specification for the superpave simple performance tests (SPT).
DOT National Transportation Integrated Search
2009-05-16
This report describes the development and establishment of a proposed Simple Performance : Test (SPT) specification in order to contribute to the asphalt materials technology in the state of : Michigan. The properties and characteristic of materials,...
42 CFR 493.1253 - Standard: Establishment and verification of performance specifications.
Code of Federal Regulations, 2014 CFR
2014-10-01
... establish performance specifications for any test system used by the laboratory before April 24, 2003. (b)(1... approved test system must do the following before reporting patient test results: (i) Demonstrate that it... following performance characteristics: (A) Accuracy. (B) Precision. (C) Reportable range of test results for...
42 CFR 493.1253 - Standard: Establishment and verification of performance specifications.
Code of Federal Regulations, 2013 CFR
2013-10-01
... establish performance specifications for any test system used by the laboratory before April 24, 2003. (b)(1... approved test system must do the following before reporting patient test results: (i) Demonstrate that it... following performance characteristics: (A) Accuracy. (B) Precision. (C) Reportable range of test results for...
42 CFR 493.1253 - Standard: Establishment and verification of performance specifications.
Code of Federal Regulations, 2012 CFR
2012-10-01
... establish performance specifications for any test system used by the laboratory before April 24, 2003. (b)(1... approved test system must do the following before reporting patient test results: (i) Demonstrate that it... following performance characteristics: (A) Accuracy. (B) Precision. (C) Reportable range of test results for...
42 CFR 493.1253 - Standard: Establishment and verification of performance specifications.
Code of Federal Regulations, 2011 CFR
2011-10-01
... establish performance specifications for any test system used by the laboratory before April 24, 2003. (b)(1... approved test system must do the following before reporting patient test results: (i) Demonstrate that it... following performance characteristics: (A) Accuracy. (B) Precision. (C) Reportable range of test results for...
Testing of optical components to assure performance in a high-average-power environment
NASA Astrophysics Data System (ADS)
Chow, Robert; Taylor, John R.; Eickelberg, William K.; Primdahl, Keith A.
1997-11-01
Evaluation and testing of the optical components used in the atomic vapor laser isotope separation plant is critical for qualification of suppliers, developments of new optical multilayer designs and manufacturing processes, and assurance of performance in the production cycle. The range of specifications requires development of specialized test equipment and methods which are not routine or readily available in industry. Specifications are given on material characteristics such as index homogeneity, subsurface damage left after polishing, microscopic surface defects and contamination, coating absorption, and high average power laser damage. The approach to testing these performance characteristics and assuring the quality throughout the production cycle is described.
Time series momentum and contrarian effects in the Chinese stock market
NASA Astrophysics Data System (ADS)
Shi, Huai-Long; Zhou, Wei-Xing
2017-10-01
This paper concentrates on the time series momentum or contrarian effects in the Chinese stock market. We evaluate the performance of the time series momentum strategy applied to major stock indices in mainland China and explore the relation between the performance of time series momentum strategies and some firm-specific characteristics. Our findings indicate that there is a time series momentum effect in the short run and a contrarian effect in the long run in the Chinese stock market. The performances of the time series momentum and contrarian strategies are highly dependent on the look-back and holding periods and firm-specific characteristics.
NASA Technical Reports Server (NTRS)
Traversi, M.; Barbarek, L. A. C.
1979-01-01
Applicable data was categorized and processed according to vehicle usage and trip parameters with consideration of payload (cargo, people, size) and driving cycles. A mission that maximizes the fuel potential savings for the total 1985 vehicle fleet was selected. Mission requirements that have a bearing on conventional and hybrid vehicle performance and characteristics were identified and formulated and a reference ICE vehicle was selected that meets or exceeds all requirements while maintaining within applicable constraints. Specifications for vehicle performance were established based on mission requirements, mission related vehicle characteristics, and fuel consumption.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Das, Atanu Kumar; Vemuri, Rama Sesha; Kutnyakov, Igor
Here, vapor-assisted dry-gel synthesis of MOF-74 structure, specifically NiMOF-74 from its synthetic precursors, was conducted with high yield and improved performance showing promise for gas (CO 2) and water adsorption applications. Unlike conventional synthesis, which takes 72 h, this kinetic study showed that NiMOF-74 forms within 12 h under dry-gel conditions with similar performance characteristics and exhibits the best performance characteristics after 48 h of heating.
Do the Managerial Characteristics of Schools Influence Their Performance?
ERIC Educational Resources Information Center
Agasisti, Tommaso; Bonomi, Francesca; Sibiano, Piergiacomo
2012-01-01
Purpose: The purpose of this paper is to investigate the role of governance and managerial characteristics of schools. More specifically, the aim is to individuate the factors that are associated to higher schools' performances, as measured through student achievement. Design/methodology/approach: The research is conducted by means of a survey in…
Establishment of key grid-connected performance index system for integrated PV-ES system
NASA Astrophysics Data System (ADS)
Li, Q.; Yuan, X. D.; Qi, Q.; Liu, H. M.
2016-08-01
In order to further promote integrated optimization operation of distributed new energy/ energy storage/ active load, this paper studies the integrated photovoltaic-energy storage (PV-ES) system which is connected with the distribution network, and analyzes typical structure and configuration selection for integrated PV-ES generation system. By combining practical grid- connected characteristics requirements and technology standard specification of photovoltaic generation system, this paper takes full account of energy storage system, and then proposes several new grid-connected performance indexes such as paralleled current sharing characteristic, parallel response consistency, adjusting characteristic, virtual moment of inertia characteristic, on- grid/off-grid switch characteristic, and so on. A comprehensive and feasible grid-connected performance index system is then established to support grid-connected performance testing on integrated PV-ES system.
Cavala, Marijana; Katić, Ratko
2010-12-01
The aim of the study was to define biomotor characteristics that determine playing performance and position in female handball. A battery of 13 variables consisting of somatotype components (3 variables), basic motor abilities (5 variables) and specific motor abilities (5 variables) were applied in a sample of 52 elite female handball players. Differences in biomotor characteristics according to playing performance and position of female handball players were determined by use of the analysis of variance (ANOVA) and discriminative analysis. Study results showed the high-quality female handball players to predominantly differ from the less successful ones in the specific factor of throw strength and basic dash factor, followed by the specific abilities of movement without and with ball, basic coordination/agility and specific ability of ball manipulation, and a more pronounced mesomorphic component. Results also revealed the wing players to be superior in the speed of movement frequency (psychomotor speed), run (explosive strength) and speed of movement with ball as compared with players at other playing positions. Also, endomorphic component was less pronounced in players at the wing and back player positions as compared with goalkeeper and pivot positions, where endomorphic component was considerably more pronounced.
Performance Characteristics of Lithium-Ion Prototype Batteries for Mars Surveyor Program 2001 Lander
NASA Technical Reports Server (NTRS)
Smart, M. C.; Ratnakumar, B. V.; Whitcanack, L.; Surampudi, S.; Byers, J.; Marsh, R. A.
2000-01-01
A viewgraph presentation outlines the scientific payload, expected launch date and tasks, and an image of the Mars Surveyor 2001 Lander components. The Lander's battery specifications are given. The program objectives for the Li-ion cells for the Lander are listed, and results performance evaluation and cycle life performance tests are outlined for different temperatures. Cell charge characteristics are described, and test data is presented for charge capacity at varying temperatures. Capacity retention and storage characteristics tests are described and results are shown.
Principals' Perceptions of Barriers to Dismissal of Poor-Performing Teachers
ERIC Educational Resources Information Center
Dandoy, Jason R.
2012-01-01
The purpose of this study is to determine which factors influence items that school principals consider "barriers" to dismissal of "incompetent" or "poor performing" teachers. This study determines if specific characteristics of schools, principals, or a combination of the two can predict the specific barriers cited…
21 CFR 809.30 - Restrictions on the sale, distribution and use of analyte specific reagents.
Code of Federal Regulations, 2010 CFR
2010-04-01
... other than providing diagnostic information to patients and practitioners, e.g., forensic, academic... include the statement for class I exempt ASR's: “Analyte Specific Reagent. Analytical and performance... and performance characteristics are not established”; and (4) Shall not make any statement regarding...
PC-403: Pioneer Venus multiprobe spacecraft mission operational characteristics document, volume 2
NASA Technical Reports Server (NTRS)
Barker, F. C.
1978-01-01
The data handling subsystem, command subsystem, communications subsystem, power subsystem, and mission operations of the Pioneer Venus multiprobe are presented. The multiprobe spacecraft performance in normal operating modes that correspond to the performance of specific functions at the time of specific events in the mission is described.
Psychosocial Characteristics of Optimum Performance in Isolated and Confined Environments (ICE)
NASA Technical Reports Server (NTRS)
Palinkas, Lawrence A.; Keeton, Kathryn E.; Shea, Camille; Leveton, Lauren B.
2010-01-01
The Behavioral Health and Performance (BHP) Element addresses human health risks in the NASA Human Research Program (HRP), including the Risk of Adverse Behavioral Conditions and the Risk of Psychiatric Disorders. BHP supports and conducts research to help characteristics and mitigate the Behavioral Medicine risk for exploration missions, and in some instances, current Flight Medical Operations. The Behavioral Health and Performance (BHP) Element identified research gaps within the Behavioral Medicine Risk, including Gap BMed6: What psychosocial characteristics predict success in an isolated, confined environment (ICE)? To address this gap, we conducted an extensive and exhaustive literature review to identify the following: 1) psychosocial characteristics that predict success in ICE environments; 2) characteristics that are most malleable; and 3) specific countermeasures that could enhance malleable characteristics.
Behavior Characteristics of Type I (75/25) Octol during Melt Pouring HE Warhead M250 (Chaparral)
1979-09-01
COVERED BEHAVIOR CHARACTERISTICS OF TYPE 1 (75/25) "OCTOL DURING MELT POURING HE WARHEAD I M250 (CHAPARRAL) 6. PERFORMING ORG. APrPORT NUMBER 7. AUTHOR...Military Specification, HMX, MIL-H-45444B, Amendment 2, dated 12 July 1977. 4 6. Military Specification, Warhead, Guided Missile, HE, M250 , Loading...CHARACTERISTICS OF TYPE i (75/25) OCTOL DURING MELT POURING HE WARHEAD M250 (CHAPARRAL) HERMAN J. FRIGAND SEPTEMBER 1979 US ARMY ARMAMENT RESEARCH AND
Performance and Safety of Lithium Ion Cells
NASA Technical Reports Server (NTRS)
Ratnakumar, B. V.; Smart, M. C.; Whitcanack, L.; Surampudi, S.; Marsh, R.
2001-01-01
This report evaluates the performance and safety of Lithium Ion (Li-Ion) cells when used in batteries. Issues discussed include the cycle life, energy efficiency, tolerance to higher charge voltage, tolerance to extended tapered charge voltage, charge on cycling, specific energy, low temperature discharge, low temperature charge, various charge characteristics, storage characteristics, and more of Li-Ion cells.
Effect of a gymnastics program on sleep characteristics in pregnant women.
Kocsis, Ildikó; Szilágyi, Tibor; Turos, János; Bakó, Aliz; Frigy, Attila
2017-04-01
The quality and quantity of sleep represent important health issues in pregnant women. Sleep disturbances could be associated, beyond alteration of quality of life, with poor pregnancy outcome. Our aim was to investigate the effect of a regular, specific, medium-term physical training program on sleep characteristics in healthy pregnant women. A total of 132 healthy pregnant women, with gestational age between 18 weeks and 22 weeks, were enrolled in a prospective study. They were allocated into two groups; the first group involved 79 women (average age, 29.4 years) who performed a specific gymnastics program of 10 weeks, and the second group involved 53 pregnant women (average age, 27.9 years) who did not perform gymnastics. All participants completed a comprehensive questionnaire at baseline and after 10 weeks concerning general data, sleep characteristics, and psycho-emotional status. The changes arising within a diverse set of characteristics were followed and compared for the two groups using parametric and nonparametric statistics. In the control group, we observed significant worsening of 12 out of the 14 studied parameters during the 10-week period. In comparison with the women who did not perform gymnastics, women who performed specific gymnastics showed the following characteristics: (1) significantly less deterioration of psycho-emotional status (stress and anxiety levels); (2) the same general pattern of decrease in sleep quality, which is related to the progression of pregnancy; and (3) a significant attenuation of the worsening of several sleep characteristics, such as restless sleep, snoring, diurnal tiredness, and excessive daytime sleepiness. Nocturnal and diurnal sleep quantity increased significantly in both groups. The 10-week training program designed for pregnant women has an overall beneficial effect on sleep characteristics, not by improving them but by attenuating their general deterioration related to the progression of pregnancy. Our data strengthen the general recommendation regarding participation of pregnant women in specific exercise programs, mainly for maintaining their psycho-emotional and general well-being. Copyright © 2017. Published by Elsevier B.V.
Das, Atanu Kumar; Vemuri, Rama Sesha; Kutnyakov, Igor; ...
2016-06-16
Here, vapor-assisted dry-gel synthesis of MOF-74 structure, specifically NiMOF-74 from its synthetic precursors, was conducted with high yield and improved performance showing promise for gas (CO 2) and water adsorption applications. Unlike conventional synthesis, which takes 72 h, this kinetic study showed that NiMOF-74 forms within 12 h under dry-gel conditions with similar performance characteristics and exhibits the best performance characteristics after 48 h of heating.
Ré, Alessandro H Nicolai; Corrêa, Umberto César; Böhme, Maria Tereza S
2010-06-01
Kick performance, anthropometric characteristics, slalom, and linear running were assessed in 49 (24 elite, 25 nonelite) postpubertal indoor soccer players in order to (a) verify whether anthropometric characteristics and physical and technical capacities can distinguish players of different competitive levels, (b) compare the kicking kinematics of these groups, with and without a defined target, and (c) compare results on the assessments and coaches' subjective rankings of the players. Thigh circumference and specific technical capacities differentiated the players by level of play; cluster analysis correctly classified 77.5% of the players. The correlation between players' standardized measures and the coaches' rankings was 0.29. Anthropometric characteristics and physical capacities do not necessarily differentiate players at post-pubertal stages and should not be overvalued during early development. Considering the coaches' rankings, performance measures outside the specific game conditions may not be useful in identification of talented players.
Lockie, Robert G; Moreno, Matthew R; Lazar, Adrina; Orjalo, Ashley J; Giuliano, Dominic V; Risso, Fabrice G; Davis, DeShaun L; Crelling, Jeff B; Lockwood, John R; Jalilvand, Farzad
2018-02-01
Lockie, RG, Moreno, MR, Lazar, A, Orjalo, AJ, Giuliano, DV, Risso, FG, Davis, DL, Crelling, JB, Lockwood, JR, and Jalilvand, F. The physical and athletic performance characteristics of Division I collegiate female soccer players by position. J Strength Cond Res 32(2): 334-343, 2018-Playing positions in soccer can exhibit different movement demands during a match, contributing to variations in physical and performance characteristics. National Collegiate Athletic Association (NCAA) soccer features different substitution rules when compared to FIFA-sanctioned matches, which could influence each players' characteristics. Therefore, this study determined the athletic performance characteristics of Division I female soccer players. Twenty-six players (3 goalkeepers; 8 defenders; 10 midfielders; 5 forwards) from the same squad completed assessments of: lower-body power (vertical and standing broad jump); linear (0-5, 0-10, 0-30 meter [m] sprint intervals) and change-of-direction (pro-agility shuttle; arrowhead change-of-direction speed test) speed; and soccer-specific fitness (Yo-Yo Intermittent Recovery Test [YYIRT] levels 1 and 2). Players were split into position groups, and a Kruskal-Wallis H test with post hoc pairwise analyses (p ≤ 0.05) calculated significant between-group differences. There were no differences in age, height, or body mass between the positions. Midfielders had a faster 0-5 m time compared with the defenders (p = 0.017) and the goalkeepers (p = 0.030). The defenders (p = 0.011) and midfielders (p = 0.013) covered a greater YYIRT2 distance compared with the goalkeepers. There were no other significant between-position differences. Overall, Division I collegiate female players from the same squad demonstrated similar characteristics as measured by soccer-specific performance tests, which could allow for flexibility in position assignments. However, a relatively homogenous squad could also indicate commonality in training prescription, particularly regarding acceleration and high-intensity running. Strength and conditioning coaches may have to consider the specific movement demands of individual positions when training these capacities.
A new perspective on hospital financial ratio analysis.
Zeller, T L; Stanko, B B; Cleverley, W O
1997-11-01
Using audit financial data in a study of 2,189 not-for-profit hospitals for the period 1989-1992, six financial characteristics of performance were defined. These characteristics are profitability factor, fixed-asset efficiency, capital structure, fixed-asset age, working capital efficiency, and liquidity. The statistical output also shows the specific sets of financial ratios that can be used to measure the six characteristics of hospital performance. The results of this study can be beneficial to healthcare financial managers, hospital boards, policy groups, and other relevant entities because it affords them a clear understanding of an institution's financial performance.
PC-402 Pioneer Venus orbiter spacecraft mission operational characteristics document
NASA Technical Reports Server (NTRS)
Barker, F. C.; Butterworth, L. W.; Daniel, R. E.; Drean, R. J.; Filetti, K. A.; Fisher, J. N.; Nowak, L. A.; Porzucki, J.; Salvatore, J. O.; Tadler, G. A.
1978-01-01
The operational characteristics of the Orbiter spacecraft and its subsystems are described. In extensive detail. Description of the nominal phases, system interfaces, and the capabilities and limitations of system level performance are included along with functional and operational descriptions at the subsystem and unit level the subtleties of nominal operation as well as detailed capabilities and limitations beyond nominal performance are discussed. A command and telemetry logic flow diagram for each subsystem is included. Each diagram encountered along each command signal path into, and each telemetry signal path out of the subsystem. Normal operating modes that correspond to the performance of specific functions at the time of specific events in the mission are also discussed. Principal backup means of performing the normal Orbiter operating modes are included.
Vandorpe, Barbara; Vandendriessche, Joric B; Vaeyens, Roel; Pion, Johan; Lefevre, Johan; Philippaerts, Renaat M; Lenoir, Matthieu
2012-01-01
Gymnastics talent identification focuses on the identification of young gymnasts who display characteristics for potential success in the future. The aim of this study was to identify which current performance characteristics are related to performance in competition 2 years later. Twenty-three female gymnasts aged 7-8 years completed a multidimensional test battery measuring anthropometric, physical, and coordinative characteristics and were technically evaluated by expert coaches. Two years later, the all-around competition results of those gymnasts now participating in elite (n = 12) and sub-elite (n = 11) competition were obtained. None of the initial measurements significantly correlated with the results of the sub-elite gymnasts 2 years later. For the elite gymnasts, a non-sport-specific motor test battery correlated strongly with the competition result, with more than 40% of the variation in competition performance being explained by the result on that test 2 years earlier. Neither the coaches' judgement nor the anthropometric and physical characteristics were sensitive enough to predict performance. A motor coordination test might be valuable in the early identification of gymnasts, as its discriminative and predictive qualities might be sufficiently powerful for selection within a relatively homogeneous population of gymnasts exhibiting similar anthropometric and physical profiles.
Vehicle performance impact on space shuttle design and concept evaluation
NASA Technical Reports Server (NTRS)
Craig, M. K.
1972-01-01
The continuing examination of widely varied space shuttle concepts makes an understanding of concept interaction with vehicle performance imperative. The estimation of vehicle performance is highly appurtenant to all aspects of shuttle design and hence performance has classically been a key indicator of overall concept desirability and potential. Vehicle performance assumes the added role of defining interactions between specific design characteristics, the sum total of which define a specific concept. Special attention is given to external tank effects.
Method for indexing and retrieving manufacturing-specific digital imagery based on image content
Ferrell, Regina K.; Karnowski, Thomas P.; Tobin, Jr., Kenneth W.
2004-06-15
A method for indexing and retrieving manufacturing-specific digital images based on image content comprises three steps. First, at least one feature vector can be extracted from a manufacturing-specific digital image stored in an image database. In particular, each extracted feature vector corresponds to a particular characteristic of the manufacturing-specific digital image, for instance, a digital image modality and overall characteristic, a substrate/background characteristic, and an anomaly/defect characteristic. Notably, the extracting step includes generating a defect mask using a detection process. Second, using an unsupervised clustering method, each extracted feature vector can be indexed in a hierarchical search tree. Third, a manufacturing-specific digital image associated with a feature vector stored in the hierarchicial search tree can be retrieved, wherein the manufacturing-specific digital image has image content comparably related to the image content of the query image. More particularly, can include two data reductions, the first performed based upon a query vector extracted from a query image. Subsequently, a user can select relevant images resulting from the first data reduction. From the selection, a prototype vector can be calculated, from which a second-level data reduction can be performed. The second-level data reduction can result in a subset of feature vectors comparable to the prototype vector, and further comparable to the query vector. An additional fourth step can include managing the hierarchical search tree by substituting a vector average for several redundant feature vectors encapsulated by nodes in the hierarchical search tree.
48 CFR 16.402-2 - Performance incentives.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Performance incentives. 16... CONTRACTING METHODS AND CONTRACT TYPES TYPES OF CONTRACTS Incentive Contracts 16.402-2 Performance incentives. (a) Performance incentives may be considered in connection with specific product characteristics (e.g...
48 CFR 16.402-2 - Performance incentives.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 1 2014-10-01 2014-10-01 false Performance incentives. 16... CONTRACTING METHODS AND CONTRACT TYPES TYPES OF CONTRACTS Incentive Contracts 16.402-2 Performance incentives. (a) Performance incentives may be considered in connection with specific product characteristics (e.g...
48 CFR 16.402-2 - Performance incentives.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Performance incentives. 16... CONTRACTING METHODS AND CONTRACT TYPES TYPES OF CONTRACTS Incentive Contracts 16.402-2 Performance incentives. (a) Performance incentives may be considered in connection with specific product characteristics (e.g...
Thermodynamic performance analysis of ramjet engine at wide working conditions
NASA Astrophysics Data System (ADS)
Ou, Min; Yan, Li; Tang, Jing-feng; Huang, Wei; Chen, Xiao-qian
2017-03-01
Although ramjet has the advantages of high-speed flying and higher specific impulse, the performance parameters will decline seriously with the increase of flight Mach number and flight height. Therefore, the investigation on the thermodynamic performance of ramjet is very crucial for broadening the working range. In the current study, a typical ramjet model has been employed to investigate the performance characteristics at wide working conditions. First of all, the compression characteristic analysis is carried out based on the Brayton cycle. The obtained results show that the specific cross-section area (A2 and A5) and the air-fuel ratio (f) have a great influence on the ramjet performance indexes. Secondly, the thermodynamic calculation process of ramjet is given from the view of the pneumatic thermal analysis. Then, the variable trends of the ramjet performance indexes with the flow conditions, the air-fuel ratio (f), the specific cross-sectional area (A2 and A5) under the fixed operating condition, equipotential dynamic pressure condition and variable dynamic pressure condition have been discussed. Finally, the optimum value of the specific cross-sectional area (A5) and the air-fuel ratio (f) of the ramjet model at a fixed work condition (Ma=3.5, H=12 km) are obtained.
Combining population and patient-specific characteristics for prostate segmentation on 3D CT images
NASA Astrophysics Data System (ADS)
Ma, Ling; Guo, Rongrong; Tian, Zhiqiang; Venkataraman, Rajesh; Sarkar, Saradwata; Liu, Xiabi; Tade, Funmilayo; Schuster, David M.; Fei, Baowei
2016-03-01
Prostate segmentation on CT images is a challenging task. In this paper, we explore the population and patient-specific characteristics for the segmentation of the prostate on CT images. Because population learning does not consider the inter-patient variations and because patient-specific learning may not perform well for different patients, we are combining the population and patient-specific information to improve segmentation performance. Specifically, we train a population model based on the population data and train a patient-specific model based on the manual segmentation on three slice of the new patient. We compute the similarity between the two models to explore the influence of applicable population knowledge on the specific patient. By combining the patient-specific knowledge with the influence, we can capture the population and patient-specific characteristics to calculate the probability of a pixel belonging to the prostate. Finally, we smooth the prostate surface according to the prostate-density value of the pixels in the distance transform image. We conducted the leave-one-out validation experiments on a set of CT volumes from 15 patients. Manual segmentation results from a radiologist serve as the gold standard for the evaluation. Experimental results show that our method achieved an average DSC of 85.1% as compared to the manual segmentation gold standard. This method outperformed the population learning method and the patient-specific learning approach alone. The CT segmentation method can have various applications in prostate cancer diagnosis and therapy.
Method for Predicting the Energy Characteristics of Li-Ion Cells Designed for High Specific Energy
NASA Technical Reports Server (NTRS)
Bennett, William, R.
2012-01-01
Novel electrode materials with increased specific capacity and voltage performance are critical to the NASA goals for developing Li-ion batteries with increased specific energy and energy density. Although performance metrics of the individual electrodes are critically important, a fundamental understanding of the interactions of electrodes in a full cell is essential to achieving the desired performance, and for establishing meaningful goals for electrode performance in the first place. This paper presents design considerations for matching positive and negative electrodes in a viable design. Methods for predicting cell-level performance, based on laboratory data for individual electrodes, are presented and discussed.
Jahan-Tigh, Richard R; Chinn, Garrett M; Rapini, Ronald P
2016-01-01
The incorporation of high-resolution cameras into smartphones has allowed for a variety of medical applications including the use of lens attachments that provide telescopic, macroscopic, and dermatoscopic data, but the feasibility and performance characteristics of such a platform for use in dermatopathology have not been described. To determine the diagnostic performance of a smartphone microscope compared to traditional light microscopy in dermatopathology specimens. A simple smartphone microscope constructed with a 3-mm ball lens was used to prospectively evaluate 1021 consecutive dermatopathology cases in a blinded fashion. Referred, consecutive specimens from the community were evaluated at a single university hospital. The performance characteristics of the smartphone platform were calculated by using conventional light microscopy as the gold standard. The sensitivity and specificity for the diagnosis of melanoma, nonmelanoma skin cancers, and other miscellaneous conditions by the phone microscopy platform, as compared with traditional light microscopy, were calculated. For basal cell carcinoma (n = 136), the sensitivity and specificity of smartphone microscopy were 95.6% and 98.1%, respectively. The sensitivity and specificity for squamous cell carcinoma (n = 94) were 89.4% and 97.3%, respectively. The lowest sensitivity was found in melanoma (n = 15) at 60%, although the specificity was high at 99.1%. The accuracy of diagnosis of inflammatory conditions and other neoplasms was variable. Mobile phone-based microscopy has excellent performance characteristics for the inexpensive diagnosis of nonmelanoma skin cancers in a setting where a traditional microscope is not available.
Specific EEG frequencies at specific brain areas and performance.
Fernández, T; Harmony, T; Silva-Pereyra, J; Fernández-Bouzas, A; Gersenowies, J; Galán, L; Carbonell, F; Marosi, E; Otero, G; Valdés, S I
2000-08-21
In this study it was shown that in adults, the frequency characteristics of EEG preceding stimuli that were followed by incorrect responses were different from the characteristics of EEG preceding stimuli that were followed by correct responses. In the recording during three different tasks that explore different neuronal networks, higher values of current preceding incorrect performance in those areas directly related to the task were found in frequencies within the delta (1.56 and 3.12 Hz) and beta bands (13.26, 14.04, 14.82, 15.6, 17.16 and 17.94 Hz), suggesting that these frequencies signal inhibition. Frequencies within the alpha band (9.36 and 12.48 Hz) showed greater energy preceding correct responses in task-specific areas, supporting previous results observed in children.
Price, C L; Brace-McDonnell, S J; Stallard, N; Bleetman, A; Maconochie, I; Perkins, G D
2016-05-01
Context Triage tools are an essential component of the emergency response to a major incident. Although fortunately rare, mass casualty incidents involving children are possible which mandate reliable triage tools to determine the priority of treatment. To determine the performance characteristics of five major incident triage tools amongst paediatric casualties who have sustained traumatic injuries. Retrospective observational cohort study using data from 31,292 patients aged less than 16 years who sustained a traumatic injury. Data were obtained from the UK Trauma Audit and Research Network (TARN) database. Interventions Statistical evaluation of five triage tools (JumpSTART, START, CareFlight, Paediatric Triage Tape/Sieve and Triage Sort) to predict death or severe traumatic injury (injury severity score >15). Main outcome measures Performance characteristics of triage tools (sensitivity, specificity and level of agreement between triage tools) to identify patients at high risk of death or severe injury. Of the 31,292 cases, 1029 died (3.3%), 6842 (21.9%) had major trauma (defined by an injury severity score >15) and 14,711 (47%) were aged 8 years or younger. There was variation in the performance accuracy of the tools to predict major trauma or death (sensitivities ranging between 36.4 and 96.2%; specificities 66.0-89.8%). Performance characteristics varied with the age of the child. CareFlight had the best overall performance at predicting death, with the following sensitivity and specificity (95% CI) respectively: 95.3% (93.8-96.8) and 80.4% (80.0-80.9). JumpSTART was superior for the triaging of children under 8 years; sensitivity and specificity (95% CI) respectively: 86.3% (83.1-89.5) and 84.8% (84.2-85.5). The triage tools were generally better at identifying patients who would die than those with non-fatal severe injury. This statistical evaluation has demonstrated variability in the accuracy of triage tools at predicting outcomes for children who sustain traumatic injuries. No single tool performed consistently well across all evaluated scenarios. Copyright © 2015 Elsevier Ltd. All rights reserved.
Hu, E; Liao, T. W.; Tiersch, T. R.
2013-01-01
Cryopreservation of fish sperm has been studied for decades at a laboratory (research) scale. However, high-throughput cryopreservation of fish sperm has recently been developed to enable industrial-scale production. This study treated blue catfish (Ictalurus furcatus) sperm high-throughput cryopreservation as a manufacturing production line and initiated quality assurance plan development. The main objectives were to identify: 1) the main production quality characteristics; 2) the process features for quality assurance; 3) the internal quality characteristics and their specification designs; 4) the quality control and process capability evaluation methods, and 5) the directions for further improvements and applications. The essential product quality characteristics were identified as fertility-related characteristics. Specification design which established the tolerance levels according to demand and process constraints was performed based on these quality characteristics. Meanwhile, to ensure integrity throughout the process, internal quality characteristics (characteristics at each quality control point within process) that could affect fertility-related quality characteristics were defined with specifications. Due to the process feature of 100% inspection (quality inspection of every fish), a specific calculation method, use of cumulative sum (CUSUM) control charts, was applied to monitor each quality characteristic. An index of overall process evaluation, process capacity, was analyzed based on in-control process and the designed specifications, which further integrates the quality assurance plan. With the established quality assurance plan, the process could operate stably and quality of products would be reliable. PMID:23872356
Fracture properties and fatigue cracking resistance of asphalt binders.
DOT National Transportation Integrated Search
2012-03-01
Several different types of modifiers are increasingly bring used to improve the performance of asphalt binders or to : achieve desired mixture production characteristics (e.g., Warm Mix Asphalt). However, current Superpave : performance specification...
Individual and Team Performance in Team-Handball: A Review
Wagner, Herbert; Finkenzeller, Thomas; Würth, Sabine; von Duvillard, Serge P.
2014-01-01
Team handball is a complex sport game that is determined by the individual performance of each player as well as tactical components and interaction of the team. The aim of this review was to specify the elements of team-handball performance based on scientific studies and practical experience, and to convey perspectives for practical implication. Scientific studies were identified via data bases of PubMed, Web of Knowledge, SPORT Discus, Google Scholar, and Hercules. A total of 56 articles met the inclusion criteria. In addition, we supplemented the review with 13 additional articles, proceedings and book sections. It was found that the specific characteristics of team-handball with frequent intensity changes, team-handball techniques, hard body confrontations, mental skills and social factors specify the determinants of coordination, endurance, strength and cognition. Although we found comprehensive studies examining individual performance in team-handball players of different experience level, sex or age, there is a lack of studies, particularly for team-handball specific training, as well as cognition and social factors. Key Points The specific characteristics of team-handball with frequent intensity changes, specific skills, hard body confrontations, mental skills and social factors define the determinants of coordination, endurance, strength and cognition. To increase individual and team performance in team-handball specific training based on these determinants have been suggested. Although there are comprehensive studies examining individual performance in team-handball players of different experience level, sex, or age are published, there is a lack of training studies, particularly for team-handball specific techniques and endurance, as well as cognition and social factors. PMID:25435773
Individual and team performance in team-handball: a review.
Wagner, Herbert; Finkenzeller, Thomas; Würth, Sabine; von Duvillard, Serge P
2014-12-01
Team handball is a complex sport game that is determined by the individual performance of each player as well as tactical components and interaction of the team. The aim of this review was to specify the elements of team-handball performance based on scientific studies and practical experience, and to convey perspectives for practical implication. Scientific studies were identified via data bases of PubMed, Web of Knowledge, SPORT Discus, Google Scholar, and Hercules. A total of 56 articles met the inclusion criteria. In addition, we supplemented the review with 13 additional articles, proceedings and book sections. It was found that the specific characteristics of team-handball with frequent intensity changes, team-handball techniques, hard body confrontations, mental skills and social factors specify the determinants of coordination, endurance, strength and cognition. Although we found comprehensive studies examining individual performance in team-handball players of different experience level, sex or age, there is a lack of studies, particularly for team-handball specific training, as well as cognition and social factors. Key PointsThe specific characteristics of team-handball with frequent intensity changes, specific skills, hard body confrontations, mental skills and social factors define the determinants of coordination, endurance, strength and cognition.To increase individual and team performance in team-handball specific training based on these determinants have been suggested.Although there are comprehensive studies examining individual performance in team-handball players of different experience level, sex, or age are published, there is a lack of training studies, particularly for team-handball specific techniques and endurance, as well as cognition and social factors.
Pharmacy student absenteeism and academic performance.
Hidayat, Levita; Vansal, Sandeep; Kim, Esther; Sullivan, Maureen; Salbu, Rebecca
2012-02-10
To assess the association of pharmacy students' personal characteristics with absenteeism and academic performance. A survey instrument was distributed to first- (P1) and second-year (P2) pharmacy students to gather characteristics including employment status, travel time to school, and primary source of educational funding. In addition, absences from specific courses and reasons for not attending classes were assessed. Participants were divided into "high" and "low" performers based on grade point average. One hundred sixty survey instruments were completed and 135 (84.3%) were included in the study analysis. Low performers were significantly more likely than high performers to have missed more than 8 hours in therapeutics courses. Low performers were significantly more likely than high performers to miss class when the class was held before or after an examination and low performers were significantly more likely to believe that participating in class did not benefit them. There was a negative association between the number of hours students' missed and their performance in specific courses. These findings provide further insight into the reasons for students' absenteeism in a college or school of pharmacy setting.
Pharmacy Student Absenteeism and Academic Performance
Hidayat, Levita; Vansal, Sandeep; Kim, Esther; Sullivan, Maureen; Salbu, Rebecca
2012-01-01
Objectives. To assess the association of pharmacy students’ personal characteristics with absenteeism and academic performance. Methods. A survey instrument was distributed to first- (P1) and second-year (P2) pharmacy students to gather characteristics including employment status, travel time to school, and primary source of educational funding. In addition, absences from specific courses and reasons for not attending classes were assessed. Participants were divided into “high” and “low” performers based on grade point average. Results. One hundred sixty survey instruments were completed and 135 (84.3%) were included in the study analysis. Low performers were significantly more likely than high performers to have missed more than 8 hours in therapeutics courses. Low performers were significantly more likely than high performers to miss class when the class was held before or after an examination and low performers were significantly more likely to believe that participating in class did not benefit them. Conclusions. There was a negative association between the number of hours students’ missed and their performance in specific courses. These findings provide further insight into the reasons for students’ absenteeism in a college or school of pharmacy setting. PMID:22412207
NASA Astrophysics Data System (ADS)
Chen, J.; Gao, G. B.; Ünlü, M. S.; Morkoç, H.
1991-11-01
High-frequency ic- vce output characteristics of bipolar transistors, derived from calculated device cutoff frequencies, are reported. The generation of high-frequency output characteristics from device design specifications represents a novel bridge between microwave circuit design and device design: the microwave performance of simulated device structures can be analyzed, or tailored transistor device structures can be designed to fit specific circuit applications. The details of our compact transistor model are presented, highlighting the high-current base-widening (Kirk) effect. The derivation of the output characteristics from the modeled cutoff frequencies are then presented, and the computed characteristics of an AlGaAs/GaAs heterojunction bipolar transistor operating at 10 GHz are analyzed. Applying the derived output characteristics to microwave circuit design, we examine large-signal class A and class B amplification.
NASA Technical Reports Server (NTRS)
Ellerbrock, Herman H , Jr
1950-01-01
In the determination of the performance of an air-cooled turbine, the cooling-air-flow characteristics between the root and the tip of the blades must be evaluated. The methods, which must be verified and the unknown functions evaluated, that are expected to permit the determination of pressure, temperature, and velocity through the blade cooling-air passages from specific investigation are presented.
SIRU utilization. Volume 1: Theory, development and test evaluation
NASA Technical Reports Server (NTRS)
Musoff, H.
1974-01-01
The theory, development, and test evaluations of the Strapdown Inertial Reference Unit (SIRU) are discussed. The statistical failure detection and isolation, single position calibration, and self alignment techniques are emphasized. Circuit diagrams of the system components are provided. Mathematical models are developed to show the performance characteristics of the subsystems. Specific areas of the utilization program are identified as: (1) error source propagation characteristics and (2) local level navigation performance demonstrations.
Sandbakk, Øyvind; Rasdal, Vegard; Bråten, Steinar; Moen, Frode; Ettema, Gertjan
2016-10-01
To compare sport-specific laboratory capacities and the annual training of world-class Nordic combined (NC) athletes with specialized ski jumpers (SJ) and cross-country (XC) skiers. Five world-class athletes from each sports discipline were compared. Ski jump imitations were performed on a 3-dimensional force plate in NC athletes and SJ, whereas XC skiing characteristics were obtained from submaximal and maximal roller ski skating on a treadmill in NC athletes and XC skiers. In addition, anthropometrics and annual training characteristics were determined. NC athletes demonstrated 9% higher body mass and showed 17% lower vertical speed in the ski jump imitation than SJ (all P < .05). NC athletes had 12% lower body mass and showed 10% lower peak treadmill speed and 12% lower body-mass-normalized peak oxygen uptake than XC skiers (all P < .05). NC athletes performed half the number of ski-jumping-specific sessions and outdoor ski jumps compared with SJ. NC athletes performed 31% less endurance training, mainly caused by lower amounts of low- and moderate-intensity training in the classical technique, whereas high-intensity strength and speed training and endurance training in the skating technique did not differ substantially from XC skiers. To simultaneously optimize endurance, explosive, and technical capacities in 2 different disciplines, world-class NC athletes train approximately two-thirds of the XC skier's endurance training volume and perform one-half of the ski-jump-specific training compared with SJ. Still, the various laboratory capacities differed only 10-17% compared with SJ and XC skiers.
Cherpanath, Thomas G V; Hirsch, Alexander; Geerts, Bart F; Lagrand, Wim K; Leeflang, Mariska M; Schultz, Marcus J; Groeneveld, A B Johan
2016-05-01
Passive leg raising creates a reversible increase in venous return allowing for the prediction of fluid responsiveness. However, the amount of venous return may vary in various clinical settings potentially affecting the diagnostic performance of passive leg raising. Therefore we performed a systematic meta-analysis determining the diagnostic performance of passive leg raising in different clinical settings with exploration of patient characteristics, measurement techniques, and outcome variables. PubMed, EMBASE, the Cochrane Database of Systematic Reviews, and citation tracking of relevant articles. Clinical trials were selected when passive leg raising was performed in combination with a fluid challenge as gold standard to define fluid responders and non-responders. Trials were included if data were reported allowing the extraction of sensitivity, specificity, and area under the receiver operating characteristic curve. Twenty-three studies with a total of 1,013 patients and 1,034 fluid challenges were included. The analysis demonstrated a pooled sensitivity of 86% (95% CI, 79-92), pooled specificity of 92% (95% CI, 88-96), and a summary area under the receiver operating characteristic curve of 0.95 (95% CI, 0.92-0.98). Mode of ventilation, type of fluid used, passive leg raising starting position, and measurement technique did not affect the diagnostic performance of passive leg raising. The use of changes in pulse pressure on passive leg raising showed a lower diagnostic performance when compared with passive leg raising-induced changes in flow variables, such as cardiac output or its direct derivatives (sensitivity of 58% [95% CI, 44-70] and specificity of 83% [95% CI, 68-92] vs sensitivity of 85% [95% CI, 78-90] and specificity of 92% [95% CI, 87-94], respectively; p < 0.001). Passive leg raising retains a high diagnostic performance in various clinical settings and patient groups. The predictive value of a change in pulse pressure on passive leg raising is inferior to a passive leg raising-induced change in a flow variable.
Liu, Wen; Jao, Ying-Ling; Williams, Kristine
2017-01-01
Background Nursing home residents with dementia experience increased risk for compromised eating performance due to intrapersonal, interpersonal, and environmental factors. Environmental stimulation is physical, social, and/or sensory stimulation present in the environment that can potentially trigger individuals’ emotion or motivate physical reactions. Beyond the personal factors, there is a lack of evidence on how environmental stimulation influences individuals’ eating performance at mealtimes. Objectives This study examined the association between environmental stimulation and eating performance among nursing home residents with dementia. Design This study was a secondary analysis using baseline videos selected from a communication intervention study, where videos were recorded to capture staff-resident interactions during care activities for nursing home residents with dementia. Videos were included in this study only if residents demonstrated eating activities at mealtimes. Sample and Setting A total of 36 videos were selected (mean length = 4 minutes). The sample included 15 residents with dementia (mean age = 86), and 19 certified nursing assistants (mean age = 36) in 8 nursing homes. Methods The dependent variable was eating performance as measured by the Level of Eating Independence scale (range: 15–36, with higher scores indicating better eating performance). The independent variables were characteristics of environmental stimulation measured by the Person-Environment Apathy Rating-Environment subscale (stimulation clarity, stimulation strength, stimulation specificity, interaction involvement, physical accessibility, and environmental feedback). Each characteristic was rated on a 1–4 scale with higher scores indicating more desirable environmental stimulation. Multilevel models were used to examine the association between eating performance and environmental stimulation, adjusting for resident characteristics (i.e., age, gender, dementia stage, function, comorbidity, psychoactive medication use) and nesting effects of residents and staff. Results Resident participants demonstrated moderate levels of eating performance (M=27.08, SD = 5.16). Eating performance was significantly lower among older residents, those with more advanced dementia, and higher comorbidity. After controlling for resident characteristics, eating performance was significantly associated with stimulation specificity (how the stimulation is delivered and tailored to the resident), and was not associated with other environmental stimulation characteristics. For each 1 point increase in stimulation specificity, eating performance increased by 8.78 points (95% CI=.59, 16.97). Conclusions Environmental stimulation that is personally tailored to a resident’ needs and preferences and directly offered to a resident contributed to better eating performance among residents with dementia. The findings will direct future development and implementation of person-directed mealtime care programs and dining environment arrangements for residents with dementia in nursing homes. PMID:28340390
Liu, Wen; Jao, Ying-Ling; Williams, Kristine
2017-06-01
Nursing home residents with dementia experience increased risk for compromised eating performance due to intrapersonal, interpersonal, and environmental factors. Environmental stimulation is physical, social, and/or sensory stimulation present in the environment that can potentially trigger individuals' emotion or motivate physical reactions. Beyond the personal factors, there is a lack of evidence on how environmental stimulation influences individuals' eating performance at mealtimes. This study examined the association between environmental stimulation and eating performance among nursing home residents with dementia. This study was a secondary analysis using baseline videos selected from a communication intervention study, where videos were recorded to capture staff-resident interactions during care activities for nursing home residents with dementia. Videos were included in this study only if residents demonstrated eating activities at mealtimes. A total of 36 videos were selected (mean length=4min). The sample included 15 residents with dementia (mean age=86), and 19 certified nursing assistants (mean age=36) in 8 nursing homes. The dependent variable was eating performance as measured by the Level of Eating Independence scale (range: 15-36, with higher scores indicating better eating performance). The independent variables were characteristics of environmental stimulation measured by the Person-Environment Apathy Rating-Environment subscale (stimulation clarity, stimulation strength, stimulation specificity, interaction involvement, physical accessibility, and environmental feedback). Each characteristic was rated on a 1-4 scale with higher scores indicating more desirable environmental stimulation. Multilevel models were used to examine the association between eating performance and environmental stimulation, adjusting for resident characteristics (i.e., age, gender, dementia stage, function, comorbidity, psychoactive medication use) and nesting effects of residents and staff. Resident participants demonstrated moderate levels of eating performance (M=27.08, SD=5.16). Eating performance was significantly lower among older residents, those with more advanced dementia, and higher comorbidity. After controlling for resident characteristics, eating performance was significantly associated with stimulation specificity (how the stimulation is delivered and tailored to the resident), and was not associated with other environmental stimulation characteristics. For each 1 point increase in stimulation specificity, eating performance increased by 8.78 points (95% CI=0.59, 16.97). Environmental stimulation that is personally tailored to a resident' needs and preferences and directly offered to a resident contributed to better eating performance among residents with dementia. The findings will direct future development and implementation of person-directed mealtime care programs and dining environment arrangements for residents with dementia in nursing homes. Copyright © 2017 Elsevier Ltd. All rights reserved.
DOT National Transportation Integrated Search
2017-09-01
Numerous studies have shown that G*/Sin, the high temperature specification parameter for current Performance Graded (PG) asphalt binder is not adequate to reflect the rutting characteristics of polymer-modified binders. Consequently, many state De...
Effects of College Programme Characteristics on Graduates' Performance
ERIC Educational Resources Information Center
García-Aracil, Adela
2015-01-01
Education programmes are designed to equip young populations with the qualifications required to assume responsible roles in specific professions and in society generally. In this paper, the focus of the analysis is on the significance of a number of higher education programme characteristics in allocating young higher education graduates across…
Teoh, Jeremy Yc; Yuen, Steffi Kk; Tsu, James Hl; Wong, Charles Kw; Ho, Brian Sh; Ng, Ada Tl; Ma, Wai-Kit; Ho, Kwan-Lun; Yiu, Ming-Kwong
2017-01-01
We investigated the performance characteristics of prostate-specific antigen (PSA) and PSA density (PSAD) in Chinese men. All Chinese men who underwent transrectal ultrasound-guided prostate biopsy (TRUS-PB) from year 2000 to 2013 were included. The receiver operating characteristic (ROC) curves for both PSA and PSAD were analyzed. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) at different cut-off levels were calculated. A total of 2606 Chinese men were included. For the ROC, the area under curve was 0.770 for PSA (P < 0.001) and 0.823 for PSAD (P < 0.001). PSA of 4.5 ng ml-1 had sensitivity of 94.4%, specificity of 14.1%, PPV of 29.5%, and NPV of 86.9%; PSAD of 0.12 ng ml-1 cc-1 had sensitivity of 94.5%, specificity of 26.6%, PPV of 32.8%, and NPV of 92.7%. On multivariate logistic regression analyses, PSA cut-off at 4.5 ng ml-1 (OR 1.61, 95% CI 1.05-2.45, P= 0.029) and PSAD cut-off at 0.12 ng ml-1 cc-1 (OR 6.22, 95% CI 4.20-9.22, P< 0.001) were significant predictors for prostate cancer detection on TRUS-PB. In conclusion, the performances of PSA and PSAD at different cut-off levels in Chinese men were very different from those in Caucasians. PSA of 4.5 ng ml-1 and PSAD of 0.12 ng ml-1 cc-1 had near 95% sensitivity and were significant predictors of prostate cancer detection in Chinese men.
Dates fruits classification using SVM
NASA Astrophysics Data System (ADS)
Alzu'bi, Reem; Anushya, A.; Hamed, Ebtisam; Al Sha'ar, Eng. Abdelnour; Vincy, B. S. Angela
2018-04-01
In this paper, we used SVM in classifying various types of dates using their images. Dates have interesting different characteristics that can be valuable to distinguish and determine a particular date type. These characteristics include shape, texture, and color. A system that achieves 100% accuracy was built to classify the dates which can be eatable and cannot be eatable. The built system helps the food industry and customer in classifying dates depending on specific quality measures giving best performance with specific type of dates.
Mechanical parameters and flight phase characteristics in aquatic plyometric jumping.
Louder, Talin J; Searle, Cade J; Bressel, Eadric
2016-09-01
Plyometric jumping is a commonly prescribed method of training focused on the development of reactive strength and high-velocity concentric power. Literature suggests that aquatic plyometric training may be a low-impact, effective supplement to land-based training. The purpose of the present study was to quantify acute, biomechanical characteristics of the take-off and flight phase for plyometric movements performed in the water. Kinetic force platform data from 12 young, male adults were collected for counter-movement jumps performed on land and in water at two different immersion depths. The specificity of jumps between environmental conditions was assessed using kinetic measures, temporal characteristics, and an assessment of the statistical relationship between take-off velocity and time in the air. Greater peak mechanical power was observed for jumps performed in the water, and was influenced by immersion depth. Additionally, the data suggest that, in the water, the statistical relationship between take-off velocity and time in air is quadratic. Results highlight the potential application of aquatic plyometric training as a cross-training tool for improving mechanical power and suggest that water immersion depth and fluid drag play key roles in the specificity of the take-off phase for jumping movements performed in the water.
Didier, Ryne A; Hopkins, Katharine L; Coakley, Fergus V; Krishnaswami, Sanjay; Spiro, David M; Foster, Bryan R
2017-09-01
Magnetic resonance imaging (MRI) has emerged as a promising modality for evaluating pediatric appendicitis. However optimal imaging protocols, including roles of contrast agents and sedation, have not been established and diagnostic criteria have not been fully evaluated. To investigate performance characteristics of rapid MRI without contrast agents or sedation in the diagnosis of pediatric appendicitis. We included patients ages 4-18 years with suspicion of appendicitis who underwent rapid MRI between October 2013 and March 2015 without contrast agent or sedation. After two-radiologist review, we determined performance characteristics of individual diagnostic criteria and aggregate diagnostic criteria by comparing MRI results to clinical outcomes. We used receiver operating characteristic (ROC) curves to determine cut-points for appendiceal diameter and wall thickness for optimization of predictive power, and we calculated area under the curve (AUC) as a measure of test accuracy. Ninety-eight MRI examinations were performed in 97 subjects. Overall, MRI had a 94% sensitivity, 95% specificity, 91% positive predictive value and 97% negative predictive value. Optimal cut-points for appendiceal diameter and wall thickness were ≥7 mm and ≥2 mm, respectively. Independently, those cut-points produced sensitivities of 91% and 84% and specificities of 84% and 43%. Presence of intraluminal fluid (30/33) or localized periappendiceal fluid (32/33) showed a significant association with acute appendicitis (P<0.01), with sensitivities of 91% and 97% and specificities of 60% and 50%. For examinations in which the appendix was not identified by one or both reviewers (23/98), the clinical outcome was negative. Rapid MRI without contrast agents or sedation is accurate for diagnosis of pediatric appendicitis when multiple diagnostic criteria are considered in aggregate. Individual diagnostic criteria including optimized cut-points of ≥7 mm for diameter and ≥2 mm for wall thickness demonstrate high sensitivities but relatively low specificities. Nonvisualization of the appendix favors a negative diagnosis.
1985-06-01
Z2~1 31DTIC TAR 31 Unaflnonc.-d Successful The S N wDefense Challenge: Distribul Systems Spare Parts Availability Dr. Joniathian D. Kaplan Lieutenant...Developing Human Perform- hardware software has not been ing that the resulting design be capable ance Specifications ( Kaplan & Crooks, developed at this...design to perform at the components: MOS-characteristics specified criteria. Although the map, analysis-characteristics map, and E Dr. Kaplan is a
Timing of Occurrence Is the Most Important Characteristic of Spot Sign.
Wang, Binli; Yan, Shenqiang; Xu, Mengjun; Zhang, Sheng; Liu, Keqin; Hu, Haitao; Selim, Magdy; Lou, Min
2016-05-01
Most previous studies have used single-phase computed tomographic angiography to detect the spot sign, a marker for hematoma expansion (HE) in spontaneous intracerebral hemorrhage. We investigated whether defining the spot sign based on timing on perfusion computed tomography (CTP) would improve its specificity for predicting HE. We prospectively enrolled supratentorial spontaneous intracerebral hemorrhage patients who underwent CTP within 6 hours of onset. Logistic regression was performed to assess the risk factors for HE and poor outcome. Predictive performance of individual CTP spot sign characteristics were examined with receiver operating characteristic analysis. Sixty-two men and 21 women with spontaneous intracerebral hemorrhage were included in this analysis. Spot sign was detected in 46% (38/83) of patients. Receiver operating characteristic analysis indicated that the timing of spot sign occurrence on CTP had the greatest area under receiver operating characteristic curve for HE (0.794; 95% confidence interval, 0.630-0.958; P=0.007); the cutoff time was 23.13 seconds. On multivariable analysis, the presence of early-occurring spot sign (ie, spot sign before 23.13 seconds) was an independent predictor not only of HE (odds ratio=28.835; 95% confidence interval, 6.960-119.458; P<0.001), but also of mortality at 3 months (odds ratio =22.377; 95% confidence interval, 1.773-282.334; P=0.016). Moreover, the predictive performance showed that the redefined early-occurring spot sign maintained a higher specificity for HE compared with spot sign (91% versus 74%). Redefining the spot sign based on timing of contrast leakage on CTP to determine early-occurring spot sign improves the specificity for predicting HE and 3-month mortality. The use of early-occurring spot sign could improve the selection of ICH patients for potential hemostatic therapy. © 2016 American Heart Association, Inc.
Small passenger car transmission test-Chevrolet 200 transmission
NASA Technical Reports Server (NTRS)
Bujold, M. P.
1980-01-01
The small passenger car transmission was tested to supply electric vehicle manufacturers with technical information regarding the performance of commerically available transmissions which would enable them to design a more energy efficient vehicle. With this information the manufacturers could estimate vehicle driving range as well as speed and torque requirements for specific road load performance characteristics. A 1979 Chevrolet Model 200 automatic transmission was tested per a passenger car automatic transmission test code (SAE J651b) which required drive performance, coast performance, and no load test conditions. The transmission attained maximum efficiencies in the mid-eighty percent range for both drive performance tests and coast performance tests. Torque, speed and efficiency curves map the complete performance characteristics for Chevrolet Model 200 transmission.
PFP Public Automatic Exchange (PAX) Commercial Grade Item (CGI) Critical Characteristics
DOE Office of Scientific and Technical Information (OSTI.GOV)
WHITE, W.F.
2000-04-04
This document specifies the critical characteristics for Commercial Grade Items (CGI) procured for use within the safety envelope of PFP's PAX system as required by HNF-PRO-268 and HNF-PRO-1819. These are the minimum specifications that the equipment must meet in order to properly perform its safety function. There may be several manufacturers or models that meet the critical characteristics for any one item.
The Effect of User Characteristics on the Efficiency of Visual Querying
ERIC Educational Resources Information Center
Bak, Peter; Meyer, Joachim
2011-01-01
Information systems increasingly provide options for visually inspecting data during the process of information discovery and exploration. Little research has dealt so far with user interactions with these systems, and specifically with the effects of characteristics of the displayed data and the user on performance with such systems. The study…
ERIC Educational Resources Information Center
Heijke, Hans; Meng, Christoph
2011-01-01
Using a unique European data-set, we investigated the significance of five higher education programme characteristics for the labour market position of the graduates: the academic versus discipline-specific character of the competencies generated; the standardization of these competencies; the combination of working and learning; the…
20 CFR 651.10 - Definitions of terms used in parts 651-658.
Code of Federal Regulations, 2011 CFR
2011-04-01
... characteristic is necessary to the individual's ability to perform the job in question. Since a BFOQ is an... participated in an application interview and which includes the applicant's personal characteristics, work... interview with a public or private employer for a specific applicant for whom the local office has no...
20 CFR 651.10 - Definitions of terms used in parts 651-658.
Code of Federal Regulations, 2010 CFR
2010-04-01
... characteristic is necessary to the individual's ability to perform the job in question. Since a BFOQ is an... participated in an application interview and which includes the applicant's personal characteristics, work... interview with a public or private employer for a specific applicant for whom the local office has no...
ERIC Educational Resources Information Center
Krach, S. Kathleen; McCreery, Michael P.; Loe, Scott A.; Jones, W. Paul
2016-01-01
Previous research demonstrates specific relationships between personality traits and general academic performance. In addition, research studies have demonstrated relationships among personality and variables related to reading fluency (i.e. speed, accuracy, automaticity, and prosody). However, little investigation has examined specific links…
Experimental and analytical comparison of flowfields in a 110 N (25 lbf) H2/O2 rocket
NASA Technical Reports Server (NTRS)
Reed, Brian D.; Penko, Paul F.; Schneider, Steven J.; Kim, Suk C.
1991-01-01
A gaseous hydrogen/gaseous oxygen 110 N (25 lbf) rocket was examined through the RPLUS code using the full Navier-Stokes equations with finite rate chemistry. Performance tests were conducted on the rocket in an altitude test facility. Preliminary parametric analyses were performed for a range of mixture ratios and fuel film cooling pcts. It is shown that the computed values of specific impulse and characteristic exhaust velocity follow the trend of the experimental data. Specific impulse computed by the code is lower than the comparable test values by about two to three percent. The computed characteristic exhaust velocity values are lower than the comparable test values by three to four pct. Thrust coefficients computed by the code are found to be within two pct. of the measured values. It is concluded that the discrepancy between computed and experimental performance values could not be attributed to experimental uncertainty.
a New Golf-Swing Robot Model Utilizing Shaft Elasticity
NASA Astrophysics Data System (ADS)
Suzuki, S.; Inooka, H.
1998-10-01
The performance of golf clubs and balls is generally evaluated by using golf-swing robots that conventionally have two or three joints with completely interrelated motion. This interrelation allows the user of this robot to specify only the initial posture and swing velocity of the robot and therefore the swing motion of this type of robot cannot be subtly adjusted to the specific characteristics of individual golf clubs. Consequently, golf-swing robots cannot accurately emulate advanced golfers, and this causes serious problems for the evaluation of golf club performance. In this study, a new golf-swing robot that can adjust its motion to both a specified value of swing velocity and the specific characteristics of individual golf clubs was analytically investigated. This robot utilizes the dynamic interference force produced by its swing motion and by shaft vibration and can therefore emulate advanced golfers and perform highly reliable evaluations of golf clubs.
NASA Astrophysics Data System (ADS)
Kim, Holak; Choe, Wonho; Lim, Youbong; Lee, Seunghun; Park, Sanghoo
2017-03-01
Magnetic field configuration is critical in Hall thrusters for achieving high performance, particularly in thrust, specific impulse, efficiency, etc. Ion beam features are also significantly influenced by magnetic field configurations. In two typical magnetic field configurations (i.e., co-current and counter-current configurations) of a cylindrical Hall thruster, ion beam characteristics are compared in relation to multiply charged ions. Our study shows that the co-current configuration brings about high ion current (or low electron current), high ionization rate, and small plume angle that lead to high thruster performance.
NASA Astrophysics Data System (ADS)
Kajiwara, Itsuro; Furuya, Keiichiro; Ishizuka, Shinichi
2018-07-01
Model-based controllers with adaptive design variables are often used to control an object with time-dependent characteristics. However, the controller's performance is influenced by many factors such as modeling accuracy and fluctuations in the object's characteristics. One method to overcome these negative factors is to tune model-based controllers. Herein we propose an online tuning method to maintain control performance for an object that exhibits time-dependent variations. The proposed method employs the poles of the controller as design variables because the poles significantly impact performance. Specifically, we use the simultaneous perturbation stochastic approximation (SPSA) to optimize a model-based controller with multiple design variables. Moreover, a vibration control experiment of an object with time-dependent characteristics as the temperature is varied demonstrates that the proposed method allows adaptive control and stably maintains the closed-loop characteristics.
van de Ven, Hardy A; Brouwer, Sandra; Koolhaas, Wendy; Goudswaard, Anneke; de Looze, Michiel P; Kecklund, Göran; Almansa, Josue; Bültmann, Ute; van der Klink, Jac J L
2016-09-01
In this cross-sectional study associations were examined between eight shift schedule characteristics with shift-specific sleep complaints and need for recovery and generic health and performance measures. It was hypothesized that shift schedule characteristics meeting ergonomic recommendations are associated with better sleep, need for recovery, health and performance. Questionnaire data were collected from 491 shift workers of 18 companies with 9 regular (semi)-continuous shift schedules. The shift schedule characteristics were analyzed separately and combined using multilevel linear regression models. The hypothesis was largely not confirmed. Relatively few associations were found, of which the majority was in the direction as expected. In particular early starts of morning shifts and many consecutive shifts seem to be avoided. The healthy worker effect, limited variation between included schedules and the cross-sectional design might explain the paucity of significant results. Copyright © 2016 Elsevier Ltd. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Polystyrene is non-biodegradable and has environmental issues associated with its disposal. A replacement for polystyrene that is biodegradable, environmentally friendly, and has similar performance characteristics is of interest to many ecologically minded companies and consumers. This study utiliz...
Procrastination, Participation, and Performance in Online Learning Environments
ERIC Educational Resources Information Center
Michinov, Nicolas; Brunot, Sophie; Le Bohec, Olivier; Juhel, Jacques; Delaval, Marine
2011-01-01
The present study focuses on a specific learner characteristic in the management of time--procrastination--, and its role in an online learning environment. More specifically, it was expected that procrastination would influence the successfulness of online learning and that this could be explained by the level of participation of learners in…
The HCMM system: Development and performance
NASA Technical Reports Server (NTRS)
Stuart, L. M., Jr.
1982-01-01
The structure and history of the heat capacity mapping mission program is reviewed and the spacecraft is described including engineering specifications, instrument design, data handling, and image characteristics.
Dalbeth, Nicola; Schumacher, H Ralph; Fransen, Jaap; Neogi, Tuhina; Jansen, Tim L; Brown, Melanie; Louthrenoo, Worawit; Vazquez-Mellado, Janitzia; Eliseev, Maxim; McCarthy, Geraldine; Stamp, Lisa K; Perez-Ruiz, Fernando; Sivera, Francisca; Ea, Hang-Korng; Gerritsen, Martijn; Scire, Carlo A; Cavagna, Lorenzo; Lin, Chingtsai; Chou, Yin-Yi; Tausche, Anne-Kathrin; da Rocha Castelar-Pinheiro, Geraldo; Janssen, Matthijs; Chen, Jiunn-Horng; Cimmino, Marco A; Uhlig, Till; Taylor, William J
2016-12-01
To identify the best-performing survey definition of gout from items commonly available in epidemiologic studies. Survey definitions of gout were identified from 34 epidemiologic studies contributing to the Global Urate Genetics Consortium (GUGC) genome-wide association study. Data from the Study for Updated Gout Classification Criteria (SUGAR) were randomly divided into development and test data sets. A data-driven case definition was formed using logistic regression in the development data set. This definition, along with definitions used in GUGC studies and the 2015 American College of Rheumatology (ACR)/European League Against Rheumatism (EULAR) gout classification criteria were applied to the test data set, using monosodium urate crystal identification as the gold standard. For all tested GUGC definitions, the simple definition of "self-report of gout or urate-lowering therapy use" had the best test performance characteristics (sensitivity 82%, specificity 72%). The simple definition had similar performance to a SUGAR data-driven case definition with 5 weighted items: self-report, self-report of doctor diagnosis, colchicine use, urate-lowering therapy use, and hyperuricemia (sensitivity 87%, specificity 70%). Both of these definitions performed better than the 1977 American Rheumatism Association survey criteria (sensitivity 82%, specificity 67%). Of all tested definitions, the 2015 ACR/EULAR criteria had the best performance (sensitivity 92%, specificity 89%). A simple definition of "self-report of gout or urate-lowering therapy use" has the best test performance characteristics of existing definitions that use routinely available data. A more complex combination of features is more sensitive, but still lacks good specificity. If a more accurate case definition is required for a particular study, the 2015 ACR/EULAR gout classification criteria should be considered. © 2016, American College of Rheumatology.
Antonelli, Giorgia; Padoan, Andrea; Aita, Ada; Sciacovelli, Laura; Plebani, Mario
2017-08-28
Background The International Standard ISO 15189 is recognized as a valuable guide in ensuring high quality clinical laboratory services and promoting the harmonization of accreditation programmes in laboratory medicine. Examination procedures must be verified in order to guarantee that their performance characteristics are congruent with the intended scope of the test. The aim of the present study was to propose a practice model for implementing procedures employed for the verification of validated examination procedures already used for at least 2 years in our laboratory, in agreement with the ISO 15189 requirement at the Section 5.5.1.2. Methods In order to identify the operative procedure to be used, approved documents were identified, together with the definition of performance characteristics to be evaluated for the different methods; the examination procedures used in laboratory were analyzed and checked for performance specifications reported by manufacturers. Then, operative flow charts were identified to compare the laboratory performance characteristics with those declared by manufacturers. Results The choice of performance characteristics for verification was based on approved documents used as guidance, and the specific purpose tests undertaken, a consideration being made of: imprecision and trueness for quantitative methods; diagnostic accuracy for qualitative methods; imprecision together with diagnostic accuracy for semi-quantitative methods. Conclusions The described approach, balancing technological possibilities, risks and costs and assuring the compliance of the fundamental component of result accuracy, appears promising as an easily applicable and flexible procedure helping laboratories to comply with the ISO 15189 requirements.
A STUDY OF COGNITIVE DEVELOPMENT AND PERFORMANCE IN CHILDREN WITH NORMAL AND DEFECTIVE HEARING.
ERIC Educational Resources Information Center
TEMPLIN, MILDRED C.
A COMPARATIVE, LONGITUDINAL STUDY WAS CONDUCTED TO EXAMINE SPECIFIC PERFORMANCE CHARACTERISTICS OF DEAF AND NORMAL CHILDREN ON SELECTED COGNITIVE TASKS. THE SAMPLE, DISTRIBUTED INTO 3 AGE CATEGORIES, CONSISTED OF 72 NORMAL AND 60 DEAF CHILDREN. MEASURES WERE SELECTED TO ASSESS THE PERFORMANCE OF SUBJECTS (1) IN DIFFERENT AREAS OF COGNITION, (2) BY…
Ma, Chunming; Liu, Yue; Lu, Qiang; Lu, Na; Liu, Xiaoli; Tian, Yiming; Wang, Rui; Yin, Fuzai
2016-02-01
The blood pressure-to-height ratio (BPHR) has been shown to be an accurate index for screening hypertension in children and adolescents. The aim of the present study was to perform a meta-analysis to assess the performance of BPHR for the assessment of hypertension. Electronic and manual searches were performed to identify studies of the BPHR. After methodological quality assessment and data extraction, pooled estimates of the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, area under the receiver operating characteristic curve and summary receiver operating characteristics were assessed systematically. The extent of heterogeneity for it was assessed. Six studies were identified for analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio values of BPHR, for assessment of hypertension, were 96% [95% confidence interval (CI)=0.95-0.97], 90% (95% CI=0.90-0.91), 10.68 (95% CI=8.03-14.21), 0.04 (95% CI=0.03-0.07) and 247.82 (95% CI=114.50-536.34), respectively. The area under the receiver operating characteristic curve was 0.9472. The BPHR had higher diagnostic accuracies for identifying hypertension in children and adolescents.
Suh, Chong Hyun; Yun, Seong Jong; Jin, Wook; Lee, Sun Hwa; Park, So Young; Ryu, Chang-Woo
2018-07-01
To assess the sensitivity and specificity of quantitative assessment of the apparent diffusion coefficient (ADC) for differentiating benign and malignant vertebral bone marrow lesions (BMLs) and compression fractures (CFs) METHODS: An electronic literature search of MEDLINE and EMBASE was conducted. Bivariate modelling and hierarchical summary receiver operating characteristic modelling were performed to evaluate the diagnostic performance of ADC for differentiating vertebral BMLs. Subgroup analysis was performed for differentiating benign and malignant vertebral CFs. Meta-regression analyses according to subject, study and diffusion-weighted imaging (DWI) characteristics were performed. Twelve eligible studies (748 lesions, 661 patients) were included. The ADC exhibited a pooled sensitivity of 0.89 (95% confidence interval [CI] 0.80-0.94) and a pooled specificity of 0.87 (95% CI 0.78-0.93) for differentiating benign and malignant vertebral BMLs. In addition, the pooled sensitivity and specificity for differentiating benign and malignant CFs were 0.92 (95% CI 0.82-0.97) and 0.91 (95% CI 0.87-0.94), respectively. In the meta-regression analysis, the DWI slice thickness was a significant factor affecting heterogeneity (p < 0.01); thinner slice thickness (< 5 mm) showed higher specificity (95%) than thicker slice thickness (81%). Quantitative assessment of ADC is a useful diagnostic tool for differentiating benign and malignant vertebral BMLs and CFs. • Quantitative assessment of ADC is useful in differentiating vertebral BMLs. • Quantitative ADC assessment for BMLs had sensitivity of 89%, specificity of 87%. • Quantitative ADC assessment for CFs had sensitivity of 92%, specificity of 91%. • The specificity is highest (95%) with thinner (< 5 mm) DWI slice thickness.
Loewenstein, Anat; Ferencz, Joseph R; Lang, Yaron; Yeshurun, Itamar; Pollack, Ayala; Siegal, Ruth; Lifshitz, Tova; Karp, Joseph; Roth, Daniel; Bronner, Guri; Brown, Justin; Mansour, Sam; Friedman, Scott; Michels, Mark; Johnston, Richards; Rapp, Moshe; Havilio, Moshe; Rafaeli, Omer; Manor, Yair
2010-01-01
The primary purpose of this study was to evaluate the ability of a home device preferential hyperacuity perimeter to discriminate between patients with choroidal neovascularization (CNV) and intermediate age-related macular degeneration (AMD), and the secondary purpose was to investigate the dependence of sensitivity on lesion characteristics. All participants were tested with the home device in an unsupervised mode. The first part of this work was retrospective using tests performed by patients with intermediate AMD and newly diagnosed CNV. In the second part, the classifier was prospectively challenged with tests performed by patients with intermediate AMD and newly diagnosed CNV. The dependence of sensitivity on lesion characteristics was estimated with tests performed by patients with CNV of both parts. In 66 eyes with CNV and 65 eyes with intermediate AMD, both sensitivity and specificity were 0.85. In the retrospective part (34 CNV and 43 intermediate AMD), sensitivity and specificity were 0.85 +/- 0.12 (95% confidence interval) and 0.84 +/- 0.11 (95% confidence interval), respectively. In the prospective part (32 CNV and 22 intermediate AMD), sensitivity and specificity were 0.84 +/- 0.13 (95% confidence interval) and 0.86 +/- 0.14 (95% confidence interval), respectively. Chi-square analysis showed no dependence of sensitivity on type (P = 0.44), location (P = 0.243), or size (P = 0.73) of the CNV lesions. A home device preferential hyperacuity perimeter has good sensitivity and specificity in discriminating between patients with newly diagnosed CNV and intermediate AMD. Sensitivity is not dependent on lesion characteristics.
Performance characteristics of digital vs film screen mammography in community practice.
Dabbous, Firas; Dolecek, Therese A; Friedewald, Sarah M; Tossas-Milligan, Katherine Y; Macarol, Tere; Summerfelt, Wm Thomas; Rauscher, Garth H
2018-05-01
We compared the performance characteristics of 297 629 full field digital (FFDM) and 416 791 screen film mammograms (SFM). Sensitivity increased with age, decreased with breast density, and was lower for more aggressive and lobular tumors. While sensitivity did not differ significantly by modality, specificity was generally 1%-2% points higher for FFDM than for SFM across age and breast density categories. The lower recall rate for FFDM vs SFM in our study may partially explain performance differences by modality. In this large health care organization, modest gains in performance were achieved with the introduction of FFDM as a replacement for SFM. © 2017 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Greene, Ben; McClure, Mark B.; Baker, David L.
2006-01-01
This work presents an overview of the International Organization for Standardization (ISO) 15859 International Standard for Space Systems Fluid Characteristics, Sampling and Test Methods Parts 1 through 13 issued in June 2004. These standards establish requirements for fluid characteristics, sampling, and test methods for 13 fluids of concern to the propellant community and propellant characterization laboratories: oxygen, hydrogen, nitrogen, helium, nitrogen tetroxide, monomethylhydrazine, hydrazine, kerosene, argon, water, ammonia, carbon dioxide, and breathing air. A comparison of the fluid characteristics, sampling, and test methods required by the ISO standards to the current military and NASA specifications, which are in use at NASA facilities and elsewhere, is presented. Many ISO standards composition limits and other content agree with those found in the applicable parts of NASA SE-S-0073, NASA SSP 30573, military performance standards and details, and Compressed Gas Association (CGA) commodity specifications. The status of a current project managed at NASA Johnson Space Center White Sands Test Facility (WSTF) to rewrite these documents is discussed.
Characterisation of the responsive properties of two running-specific prosthetic models.
Grobler, Lara; Ferreira, Suzanne; Vanwanseele, Benedicte; Terblanche, Elmarie E
2017-04-01
The need for information regarding running-specific prosthetic properties has previously been voiced. Such information is necessary to assist in athletes' prostheses selection. This study aimed to describe the characteristics of two commercially available running-specific prostheses. The running-specific prostheses were tested (in an experimental setup) without the external interference of athlete performance variations. Four stiffness categories of each running-specific prosthetic model (Xtend ™ and Xtreme ™ ) were tested at seven alignment setups and three drop masses (28, 38 and 48 kg). Results for peak ground reaction force (GRF peak ), contact time ( t c ), flight time ( t f ), reactive strength index (RSI) and maximal compression (Δ L) were determined during controlled dropping of running-specific prostheses onto a force platform with different masses attached to the experimental setup. No statistically significant differences were found between the different setups of the running-specific prostheses. Statistically significant differences were found between the two models for all outcome variables (GRF peak , Xtend > Xtreme; t c , Xtreme > Xtend; t f , Xtreme > Xtend; RSI, Xtend > Xtreme; Δ L, Xtreme > Xtend; p < 0.05). These findings suggest that the Xtreme stores more elastic energy than the Xtend, leading to a greater performance response. The specific responsive features of blades could guide sprint athletes in their choice of running-specific prostheses. Clinical relevance Insights into the running-specific prosthesis (RSP) properties and an understanding of its responsive characteristics have implications for athletes' prosthetic choice. Physiologically and metabolically, a short sprint event (i.e. 100 m) places different demands on the athlete than a long sprint event (i.e. 400 m), and the RSP should match these performance demands.
Steinhauser, Johann; Hamm, Ulrich
2018-08-01
The research on nutrition, health, and risk reduction claims (NHR claims) shows a lack of consensus as to whether these claims have a positive or negative effect on consumer's preferences and purchase behavior. This issue has been highlighted by many authors. Therefore, a comprehensive literature review was performed to find reasons for contradictory results. First, a theoretical framework was developed which divided the determinants of the effects of NHR claims on consumers' preferences and purchase behavior into consumer and product-specific characteristics. Additionally, a categorization for the different NHR claim types was constructed to make the studies comparable. Afterwards, the scientific literature from the 1980s until May 2017 was scanned and 66 articles were found to be relevant. Consumer-specific characteristics such as nutrition knowledge, health motivation, familiarity, and socio-demographic characteristics were found to influence the NHR claim effect. Important product-specific characteristics were the perceived healthiness of the food product, the interaction between the product and the nutrient in the NHR claim, and the interaction between the claimed benefit and the NHR claim type. The consumer's nutrition knowledge and the product's perceived healthiness were deemed to be the most promising determinants for further investigation. Copyright © 2018 Elsevier Ltd. All rights reserved.
Piezoelectric Actuator with Frequency Characteristics for a Middle-Ear Implant.
Shin, Dong Ho; Cho, Jin-Ho
2018-05-24
The design and implementation of a novel piezoelectric-based actuator for an implantable middle-ear hearing aid is described in this paper. The proposed actuator has excellent low-frequency output characteristics, and can generate high output in a specific frequency band by adjusting the mechanical resonance. The actuator consists of a piezoelectric element, a miniature bellows, a cantilever membrane, a metal ring support, a ceramic tip, and titanium housing. The optimal structure of the cantilever-membrane design, which determines the frequency characteristics of the piezoelectric actuator, was derived through finite element analysis. Based on the results, the piezoelectric actuator was implemented, and its performance was verified through a cadaveric experiment. It was confirmed that the proposed actuator provides better performance than currently used actuators, in terms of frequency characteristics.
NASA Technical Reports Server (NTRS)
Smart, M. C.; Hossain, S.; Ratnakumar, B. V.; Loutfy, R.; Whitcanack, L. D.; Chin, K. B.; Davies, E. D.; Surampudi, S.; Narayanan, S. R.
2004-01-01
NASA has interest in secondary energy storage batteries that display high specific energy, high energy density, long life characteristics, and perform well over a wide range of temperatures, in order to enable a number of future applications.
40 CFR Figure E-1 to Subpart E of... - Designation Testing Checklist
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Field Sampling Procedure (§ 53.30, .31, .34) Design Specification Tests Filter (L-6) Range of... Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II... Process or of Documented Evidence: Performance, Design or Application Spec. Corresponding to Sections of...
40 CFR Figure E-1 to Subpart E of... - Designation Testing Checklist
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Field Sampling Procedure (§ 53.30, .31, .34) Design Specification Tests Filter (L-6) Range of... Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II... Process or of Documented Evidence: Performance, Design or Application Spec. Corresponding to Sections of...
40 CFR Figure E-1 to Subpart E of... - Designation Testing Checklist
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Field Sampling Procedure (§ 53.30, .31, .34) Design Specification Tests Filter ( L-6) Range of... Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II... Process or of Documented Evidence: Performance, Design or Application Spec. Corresponding to Sections of...
14 CFR 91.1087 - Approval of aircraft simulators and other training devices.
Code of Federal Regulations, 2010 CFR
2010-01-01
... subpart must meet the following requirements: (1) It must be specifically approved for— (i) The program... maintain the performance, functional, and other characteristics that are required for approval. (3... conform with any modification to the aircraft being simulated that changes the performance, functional, or...
USDA-ARS?s Scientific Manuscript database
Detection and rapid response to in-season changes of soil nutrient availability and plant needs with weather conditions and site-specific characteristics are essential to the optimal performance of an agronomic crop production system. With recent advances in material science, detector design and se...
Foot loading characteristics during three fencing-specific movements.
Trautmann, Caroline; Martinelli, Nicolo; Rosenbaum, Dieter
2011-12-01
Plantar pressure characteristics during fencing movements may provide more specific information about the influence of foot loading on overload injury patterns. Twenty-nine experienced fencers participated in the study. Three fencing-specific movements (lunge, advance, retreat) and normal running were performed with three different shoe models: Ballestra (Nike, USA), Adistar Fencing Lo (Adidas, Germany), and the fencers' own shoes. The Pedar system (Novel, Munich, Germany) was used to collect plantar pressures at 50 Hz. Peak pressures, force-time integrals and contact times for five foot regions were compared between four athletic tasks in the lunge leg and supporting leg. Plantar pressure analysis revealed characteristic pressure distribution patterns for the fencing movements. For the lunge leg, during the lunge and advance movements the heel is predominantly loaded; during retreat, it is the hallux. For the supporting leg, during the lunge and advance movements the forefoot is predominantly loaded; during retreat, it is the hallux. Fencing-specific movements load the plantar surface in a distinct way compared with running. An effective cushioning in the heel and hallux region would help to minimize foot loading during fencing-specific movements.
Ellegast, Rolf P; Kraft, Kathrin; Groenesteijn, Liesbeth; Krause, Frank; Berger, Helmut; Vink, Peter
2012-03-01
Prolonged and static sitting postures provoke physical inactivity at VDU workplaces and are therefore discussed as risk factors for the musculoskeletal system. Manufacturers have designed specific dynamic office chairs featuring structural elements which promote dynamic sitting and therefore physical activity. The aim of the present study was to evaluate the effects of four specific dynamic chairs on erector spinae and trapezius EMG, postures/joint angles and physical activity intensity (PAI) compared to those of a conventional standard office chair. All chairs were fitted with sensors for measurement of the chair parameters (backrest inclination, forward and sideward seat pan inclination), and tested in the laboratory by 10 subjects performing 7 standardized office tasks and by another 12 subjects in the field during their normal office work. Muscle activation revealed no significant differences between the specific dynamic chairs and the reference chair. Analysis of postures/joint angles and PAI revealed only a few differences between the chairs, whereas the tasks performed strongly affected the measured muscle activation, postures and kinematics. The characteristic dynamic elements of each specific chair yielded significant differences in the measured chair parameters, but these characteristics did not appear to affect the sitting dynamics of the subjects performing their office tasks. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Choi, Young Jun; Baek, Jung Hwan; Park, Hye Sun; Shim, Woo Hyun; Kim, Tae Yong; Shong, Young Kee; Lee, Jeong Hyun
2017-04-01
An initial clinical assessment is described of a new, commercially available, computer-aided diagnosis (CAD) system using artificial intelligence (AI) for thyroid ultrasound, and its performance is evaluated in the diagnosis of malignant thyroid nodules and categorization of nodule characteristics. Patients with thyroid nodules with decisive diagnosis, whether benign or malignant, were consecutively enrolled from November 2015 to February 2016. An experienced radiologist reviewed the ultrasound image characteristics of the thyroid nodules, while another radiologist assessed the same thyroid nodules using the CAD system, providing ultrasound characteristics and a diagnosis of whether nodules were benign or malignant. The diagnostic performance and agreement of US characteristics between the experienced radiologist and the CAD system were compared. In total, 102 thyroid nodules from 89 patients were included; 59 (57.8%) were benign and 43 (42.2%) were malignant. The CAD system showed a similar sensitivity as the experienced radiologist (90.7% vs. 88.4%, p > 0.99), but a lower specificity and a lower area under the receiver operating characteristic (AUROC) curve (specificity: 74.6% vs. 94.9%, p = 0.002; AUROC: 0.83 vs. 0.92, p = 0.021). Classifications of the ultrasound characteristics (composition, orientation, echogenicity, and spongiform) between radiologist and CAD system were in substantial agreement (κ = 0.659, 0.740, 0.733, and 0.658, respectively), while the margin showed a fair agreement (κ = 0.239). The sensitivity of the CAD system using AI for malignant thyroid nodules was as good as that of the experienced radiologist, while specificity and accuracy were lower than those of the experienced radiologist. The CAD system showed an acceptable agreement with the experienced radiologist for characterization of thyroid nodules.
Performance characteristics of ambient temperature secondary lithium cells
NASA Technical Reports Server (NTRS)
Deligiannis, F.; Shen, D.; Subbarao, S.; Whitcanack, L.; Halpert, G.
1988-01-01
State of art ambient temperature secondary lithium cells were evaluated to determine their performance capability and limitations and to assess the present status of the technology of these cells. Li-MoS2, Li-NbSe3 and Li-TiS2 cells were evaluated for their charge/discharge characteristics, rate capability, and cycle life performance. The cells evaluated have a cycle life of 100-250 cycles at moderate discharge rates (C/5). The specific energy of these cells is between 50 and 100 Wh/Kg, depending upon the system. This paper describes the details of the cell designs, the test procedures, and the results of the evaluation studies.
Integrated flight/propulsion control system design based on a decentralized, hierarchical approach
NASA Technical Reports Server (NTRS)
Mattern, Duane; Garg, Sanjay; Bullard, Randy
1989-01-01
A sample integrated flight/propulsion control system design is presented for the piloted longitudinal landing task with a modern, statistically unstable fighter aircraft. The design procedure is summarized. The vehicle model used in the sample study is described, and the procedure for partitioning the integrated system is presented along with a description of the subsystems. The high-level airframe performance specifications and control design are presented and the control performance is evaluated. The generation of the low-level (engine) subsystem specifications from the airframe requirements are discussed, and the engine performance specifications are presented along with the subsystem control design. A compensator to accommodate the influence of airframe outputs on the engine subsystem is also considered. Finally, the entire closed loop system performance and stability characteristics are examined.
Integrated flight/propulsion control system design based on a decentralized, hierarchical approach
NASA Technical Reports Server (NTRS)
Mattern, Duane; Garg, Sanjay; Bullard, Randy
1989-01-01
A sample integrated flight/propulsion control system design is presented for the piloted longitiudinal landing task with a modern, statistically unstable fighter aircraft. The design procedure is summarized, the vehicle model used in the sample study is described, and the procedure for partitioning the integrated system is presented along with a description of the subsystems. The high-level airframe performance specifications and control design are presented and the control performance is evaluated. The generation of the low-level (engine) subsystem specifications from the airframe requirements are discussed, and the engine performance specifications are presented along with the subsystem control design. A compensator to accommodate the influence of airframe outputs on the engine subsystem is also considered. Finally, the entire closed loop system performance and stability characteristics are examined.
Performance characteristics of broth-only cultures after revision total joint arthroplasty.
Smith, Eric B; Cai, Jenny; Wynne, Rachael; Maltenfort, Mitchell; Good, Robert P
2014-11-01
Surgeons frequently obtain intraoperative cultures at the time of revision total joint arthroplasty. The use of broth or liquid medium before applying the sample to the agar medium may be associated with contamination and false-positive cultures; however, the degree to which this is the case is not known. We (1) calculated the performance characteristics of broth-only cultures (sensitivity, specificity, positive predictive value, and negative predictive value) and (2) characterized the organisms identified in broth to determine whether a specific organism showed increased proclivity for true-positive periprosthetic joint infection (PJI). A single-institution retrospective chart review was performed on 257 revision total joint arthroplasties from 2009 through 2010. One hundred ninety (74%) had cultures for review. All culture results, as well as treatment, if any, were documented and patients were followed for a minimum of 1 year for evidence of PJI. Cultures were measured as either positive from the broth only or broth negative. The true diagnosis of infection was determined by the Musculoskeletal Infection Society criteria during the preoperative workup or postoperatively at 1 year for purposes of calculating the performance characteristics of the broth-only culture. The sensitivity, specificity, positive predictive value, and negative predictive value were 19%, 88%, 13%, and 92%, respectively. The most common organism identified was coagulase-negative Staphylococcus (16 of 24 cases, 67%). Coagulase-negative Staphylococcus was present in all three true-positive cases; however, it was also found in 13 of the false-positive cases. The broth-only positive cultures showed poor sensitivity and positive predictive value but good specificity and negative predictive value. The good specificity indicates that it can help to rule in the presence of PJI; however, the poor sensitivity makes broth-only culture an unreliable screening test. We recommend that broth-only culture results be carefully scrutinized and decisions on the diagnosis and treatment of infection should be based specifically on the Musculoskeletal Infection Society criteria. Level IV, diagnostic study. See Instructions for Authors for a complete description of levels of evidence.
Performance of the AMY central drift chamber in a high magnetic field
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ueno, Koji
1988-01-01
This note describes the design characteristics of the AMY central drift changer (CDC) and its performance during its operation for the first year since it was installed in the AMY solenoid on October 24, 1986. In general, the chamber has performed according to our original specifications, providing us with good efficiency and excellent spatial resolution. 5 figs.
Advanced 35 W Free-Piston Stirling Engine for Space Power Applications
NASA Astrophysics Data System (ADS)
Wood, J. Gary; Lane, Neill
2003-01-01
This paper presents the projected performance and overall design characteristics of a high efficiency, low mass 35 W free-piston Stirling engine design. Overall (engine plus linear alternator) thermodynamic performance greater than 50% of Carnot, with a specific power close to 100 W/kg appears to be a reasonable goal at this small power level. Supporting test data and analysis results from exiting engines are presented. Design implications of high specific power in relatively low power engines is presented and discussed.
Covariance of engineering management characteristics with engineering employee performance
NASA Astrophysics Data System (ADS)
Hesketh, Andrew Arthur
1998-12-01
As business in the 1990's grapples with the impact of continuous improvement and quality to meet market demands, there is an increased need to improve the leadership capabilities of our managers. Engineers have indicated desire for certain managerial characteristics in their leadership but there have been no studies completed that approached the problem of determining what managerial characteristics were best at improving employee performance. This study addressed the idea of identifying certain managerial characteristics that enhance employee performance. In the early 1990's, McDonnell Douglas Aerospace in St. Louis used a forced distribution system and allocated 35% of its employees into a "exceeds expectations" category and 60% into a "meets expectations" category. A twenty-question 5 point Likert scale survey on managerial capabilities was administered to a sample engineering population that also obtained their "expectations" category. A single factor ANOVA on the survey results determined a statistical difference between the "exceeds" and "meets" employees with four of the managerial capability questions. The "exceeds expectations" employee indicated that supervision did a better job of supporting subordinate development, clearly communicating performance expectations, and providing timely performance feedback when compared to the "meets expectations" employee. The "meets expectations" employee felt that their opinions, when different from their supervisor's, were more often ignored when compared to the "exceeds expectations" employee. These four questions relate to two specific managerial characteristics, "gaining (informal) authority and support" or "control" characteristic and "providing assistance and guidance" or "command" characteristic, that can be emphasized in managerial training programs.
A review of hospital characteristics associated with improved performance.
Brand, Caroline A; Barker, Anna L; Morello, Renata T; Vitale, Michael R; Evans, Sue M; Scott, Ian A; Stoelwinder, Johannes U; Cameron, Peter A
2012-10-01
The objective of this review was to critically appraise the literature relating to associations between high-level structural and operational hospital characteristics and improved performance. The Cochrane Library, MEDLINE (Ovid), CINAHL, proQuest and PsychINFO were searched for articles published between January 1996 and May 2010. Reference lists of included articles were reviewed and key journals were hand searched for relevant articles. and data extraction Studies were included if they were systematic reviews or meta-analyses, randomized controlled trials, controlled before and after studies or observational studies (cohort and cross-sectional) that were multicentre, comparative performance studies. Two reviewers independently extracted data, assigned grades of evidence according to the Australian National Health and Medical Research Council guidelines and critically appraised the included articles. Data synthesis Fifty-seven studies were reported within 12 systematic reviews and 47 observational articles. There was heterogeneity in use and definition of performance outcomes. Hospital characteristics investigated were environment (incentives, market characteristics), structure (network membership, ownership, teaching status, geographical setting, service size) and operational design (innovativeness, leadership, organizational culture, public reporting and patient safety practices, information technology systems and decision support, service activity and planning, workforce design, staff training and education). The strongest evidence for an association with overall performance was identified for computerized physician order entry systems. Some evidence supported the associations with workforce design, use of financial incentives, nursing leadership and hospital volume. There is limited, mainly low-quality evidence, supporting the associations between hospital characteristics and healthcare performance. Further characteristic-specific systematic reviews are indicated.
Le Strat, Yann
2017-01-01
The objective of this paper is to evaluate a panel of statistical algorithms for temporal outbreak detection. Based on a large dataset of simulated weekly surveillance time series, we performed a systematic assessment of 21 statistical algorithms, 19 implemented in the R package surveillance and two other methods. We estimated false positive rate (FPR), probability of detection (POD), probability of detection during the first week, sensitivity, specificity, negative and positive predictive values and F1-measure for each detection method. Then, to identify the factors associated with these performance measures, we ran multivariate Poisson regression models adjusted for the characteristics of the simulated time series (trend, seasonality, dispersion, outbreak sizes, etc.). The FPR ranged from 0.7% to 59.9% and the POD from 43.3% to 88.7%. Some methods had a very high specificity, up to 99.4%, but a low sensitivity. Methods with a high sensitivity (up to 79.5%) had a low specificity. All methods had a high negative predictive value, over 94%, while positive predictive values ranged from 6.5% to 68.4%. Multivariate Poisson regression models showed that performance measures were strongly influenced by the characteristics of time series. Past or current outbreak size and duration strongly influenced detection performances. PMID:28715489
Development of a high-specific-speed centrifugal compressor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rodgers, C.
1997-07-01
This paper describes the development of a subscale single-stage centrifugal compressor with a dimensionless specific speed (Ns) of 1.8, originally designed for full-size application as a high volume flow, low pressure ratio, gas booster compressor. The specific stage is noteworthy in that it provides a benchmark representing the performance potential of very high-specific-speed compressors, of which limited information is found in the open literature. Stage and component test performance characteristics are presented together with traverse results at the impeller exit. Traverse test results were compared with recent CFD computational predictions for an exploratory analytical calibration of a very high-specific-speed impellermore » geometry. The tested subscale (0.583) compressor essentially satisfied design performance expectations with an overall stage efficiency of 74% including, excessive exit casing losses. It was estimated that stage efficiency could be increased to 81% with exit casing losses halved.« less
Arcjet thruster research and technology
NASA Technical Reports Server (NTRS)
Makel, Darby B.; Cann, Gordon L.
1988-01-01
The design, analysis, and performance testing of an advanced lower power arcjet is described. A high impedance, vortex stabilized 1-kw class arcjet has been studied. A baseline research thruster has been built and endurance and performance tested. This advanced arcjet has demonstrated long lifetime characteristics, but lower than expected performance. Analysis of the specific design has identified modifications which should improve performance and maintain the long life time shown by the arcjet.
Long term pavement performance computed parameter : frost penetration
DOT National Transportation Integrated Search
2008-11-01
As the pavement design process moves toward mechanistic-empirical techniques, knowledge of seasonal changes in pavement structural characteristics becomes critical. Specifically, frost penetration information is necessary for determining the effect o...
High Specific Energy NiH2 Batteries for GEO Satellites
NASA Technical Reports Server (NTRS)
Borthomieu, Y.; Fabre, M.
2001-01-01
This viewgraph presentation outlines the SAFT qualification status history, cell and battery modifications, overall battery characteristics, satellite programs and battery types delivered, and battery performances for selected satellite missions.
Measures of accuracy and performance of diagnostic tests.
Drobatz, Kenneth J
2009-05-01
Diagnostic tests are integral to the practice of veterinary cardiology, any other specialty, and general veterinary medicine. Developing and understanding diagnostic tests is one of the cornerstones of clinical research. This manuscript describes the diagnostic test properties including sensitivity, specificity, predictive value, likelihood ratio, receiver operating characteristic curve. Review of practical book chapters and standard statistics manuscripts. Diagnostics such as sensitivity, specificity, predictive value, likelihood ratio, and receiver operating characteristic curve are described and illustrated. Basic understanding of how diagnostic tests are developed and interpreted is essential in reviewing clinical scientific papers and understanding evidence based medicine.
Apostol, Izydor; Kelner, Drew; Jiang, Xinzhao Grace; Huang, Gang; Wypych, Jette; Zhang, Xin; Gastwirt, Jessica; Chen, Kenneth; Fodor, Szilan; Hapuarachchi, Suminda; Meriage, Dave; Ye, Frank; Poppe, Leszek; Szpankowski, Wojciech
2012-12-01
To predict precision and other performance characteristics of chromatographic purity methods, which represent the most widely used form of analysis in the biopharmaceutical industry. We have conducted a comprehensive survey of purity methods, and show that all performance characteristics fall within narrow measurement ranges. This observation was used to develop a model called Uncertainty Based on Current Information (UBCI), which expresses these performance characteristics as a function of the signal and noise levels, hardware specifications, and software settings. We applied the UCBI model to assess the uncertainty of purity measurements, and compared the results to those from conventional qualification. We demonstrated that the UBCI model is suitable to dynamically assess method performance characteristics, based on information extracted from individual chromatograms. The model provides an opportunity for streamlining qualification and validation studies by implementing a "live validation" of test results utilizing UBCI as a concurrent assessment of measurement uncertainty. Therefore, UBCI can potentially mitigate the challenges associated with laborious conventional method validation and facilitates the introduction of more advanced analytical technologies during the method lifecycle.
Development of Independent-type Optical CT
NASA Astrophysics Data System (ADS)
Yamaguchi, Tatsushi; Shiozawa, Daigoro; Rokunohe, Toshiaki; Kida, Junzo; Zhang, Wei
Optical current transformers (optical CTs) have features that they can be made much smaller and lighter than conventional electromagnetic induction transformers by their simple structure, and contribute to improvement of equipment reliability because of their excellent surge resistance performance. Authors consider optical CTs to be next generation transformers, and are conducting research and development of optical CTs aiming to apply to measuring and protection in electric power systems. Specifically we developed an independent-type optical CT by utilizing basic data of optical CTs accumulated for large current characteristics, temperature characteristics, vibration resistance characteristics, and so on. In performance verification, type tests complying with IEC standards, such as short-time current tests, insulation tests, accuracy tests, and so on, showed good results. This report describes basic principle and configuration of optical CTs. After that, as basic characteristics of optical CTs, conditions and results of verification tests for dielectric breakdown characteristics of sensor fibers, large current characteristics, temperature characteristics, and vibration resistance characteristics are described. Finally, development outline of the independent-type optical CT aiming to apply to all digital substation and its type tests results are described.
NASA Technical Reports Server (NTRS)
Powell, W. B.
1973-01-01
Thrust chamber performance is evaluated in terms of an analytical model incorporating all the loss processes that occur in a real rocket motor. The important loss processes in the real thrust chamber were identified, and a methodology and recommended procedure for predicting real thrust chamber vacuum specific impulse were developed. Simplified equations for the calculation of vacuum specific impulse are developed to relate the delivered performance (both vacuum specific impulse and characteristic velocity) to the ideal performance as degraded by the losses corresponding to a specified list of loss processes. These simplified equations enable the various performance loss components, and the corresponding efficiencies, to be quantified separately (except that interaction effects are arbitrarily assigned in the process). The loss and efficiency expressions presented can be used to evaluate experimentally measured thrust chamber performance, to direct development effort into the areas most likely to yield improvements in performance, and as a basis to predict performance of related thrust chamber configurations.
Specific characteristics of negative corona currents generated in short point-plane gap
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Zhen; Zhang, Bo; He, Jinliang
The Trichel pulse is a typical kind of negative corona current observed in electronegative gases with a highly regular form. The characteristics of the Trichel pulse, such as the repetition frequency, the amplitude of each pulse, and the mean current, are dependent on different discharge conditions. Quite many scholars have studied the mean current and the current-voltage characteristic of Trichel pulses, yet the specific characteristics of the pulses have barely been investigated. In this paper, a series of experiments were carried out in a short point-to-plane discharge gap to investigate the detailed characteristics of Trichel pulses. After numerical fitting ofmore » the experiment results was performed, a new set of empirical formulas were derived to predict the specific characteristics of the negative corona current under different conditions. Different from existing literature, this paper uses as variables the average electric field intensity and the corona inception field intensity which is independent of the gap spacing in the empirical formulas. In the experiments, an inverse correlation between amplitude and repetition frequency of the pulses was observed. Based on the investigation of the remaining space charge in the discharge gap, this correlation is theoretically proved to be caused by the influence of space charges.« less
Truck characteristics analysis
DOT National Transportation Integrated Search
1998-01-01
This report documents the early observations from the Long-Term Pavement Performance (LTPP) Specific Pavement Studies (SPS) conducted as part of the LTPP Program Data Insight conducted to identify initial findings from the test sections established f...
Evaluation of rubblization project in Ohio.
DOT National Transportation Integrated Search
2011-03-01
This study was initiated to systematically analyze the performance characteristics of ODOTs completed rubblization and roll (R/R) projects and to develop guidelines regarding improved specifications. : The study was conducted in three parts namely...
Theoretical Performance of Liquid Hydrogen with Liquid Oxygen as a Rocket Propellant
NASA Technical Reports Server (NTRS)
Gordon, Sanford; McBride, Bonnie J.
1959-01-01
Theoretical rocket performance for both equilibrium and frozen composition during expansion was calculated for the propellant combination liquid hydrogen and liquid oxygen at four chamber pressures (60, 150, 300, and 600 lb/sq in. abs) and a wide range of pressure ratios (1 to 4000) and oxidant-fuel ratios (1.190 to 39.683). Data are given to estimate performance parameters at chamber pressures other than those for which data are tabulated. The parameters included are specific impulse, specific impulse in vacuum, combustion-chamber temperature, nozzle-exit temperature, molecular weight, molecular-weight derivatives, characteristic velocity, coefficient of thrust, ratio of nozzle-exit area to throat area, specific heat at constant pressure, isentropic exponent, viscosity, thermal conductivity, Mach number, and equilibrium gas compositions.
Can Sample-Specific Simulations Help Detect Low Base-Rate Taxonicity?
ERIC Educational Resources Information Center
Beach, Steven R. H.; Amir, Nader; Bau, Jinn Jonp
2005-01-01
The authors examined the role of the sample-specific simulations (SSS; A. M. Ruscio & J. Ruscio, 2002; J. Ruscio & A. M. Ruscio, 2004) procedure in detecting low base-rate taxa that might otherwise prove elusive. The procedure preserved key distributional characteristics for moderate to high base-rate taxa, but it performed inadequately for low…
Retail Lamps Study 3.1: Dimming, Flicker, and Power Quality Characteristics of LED A Lamps
DOE Office of Scientific and Technical Information (OSTI.GOV)
Royer, Michael P.; Poplawski, Michael E.; Brown, Charles C.
2014-12-01
To date, all three reports in the retail lamps series have focused on basic performance parameters, such as lumen output, efficacy, and color quality. This report goes a step further, examining the photoelectric characteristics (i.e., dimming and flicker) of a subset of lamps from CALiPER Retails Lamps Study 3. Specifically, this report focuses on the dimming, power quality, and flicker characteristics of 14 LED A lamps, as controlled by four different retail-available dimmers. The results demonstrate notable variation across the various lamps, but little variation between the four dimmers. Overall, the LED lamps: ~tended to have higher relative light outputmore » compared to the incandescent and halogen benchmark at the same dimmer output signal (RMS voltage). The lamps’ dimming curves (i.e., the relationship between control signal and relative light output) ranged from linear to very similar to the square-law curve typical of an incandescent lamp. ~generally exhibited symmetrical behavior—the same dimming curve—when measured proceeding from maximum to minimum or minimum to maximum control signal. ~mostly dimmed below 10% of full light output, with some exceptions for specific lamp and dimmer combinations ~exhibited a range of flicker characteristics, with many comparing favorably to the level typical of a magnetically-ballasted fluorescent lamp through at least a majority of the dimming range. ~ always exceeded the relative (normalized) efficacy over the dimming range of the benchmark lamps, which rapidly decline in efficacy when they are dimmed. This report generally does not attempt to rank the performance of one product compared to another, but instead focuses on the collective performance of the group versus conventional incandescent or halogen lamps, the performance of which is likely to be the baseline for a majority of consumers. Undoubtedly, some LED lamps perform better—or more similar to conventional lamps—than others. Some perform desirably for one characteristic, but not others. Consumers (and specifiers) may have a hard time distinguishing better-performing lamps from one another; at this time, physical experimentation is likely the best evaluation tool.« less
Elliott, D.G.; Applegate, L.J.; Murray, A.L.; Purcell, M.K.; McKibben, C.L.
2013-01-01
No gold standard assay exhibiting error-free classification of results has been identified for detection of Renibacterium salmoninarum, the causative agent of salmonid bacterial kidney disease. Validation of diagnostic assays for R. salmoninarum has been hindered by its unique characteristics and biology, and difficulties in locating suitable populations of reference test animals. Infection status of fish in test populations is often unknown, and it is commonly assumed that the assay yielding the most positive results has the highest diagnostic accuracy, without consideration of misclassification of results. In this research, quantification of R. salmoninarum in samples by bacteriological culture provided a standardized measure of viable bacteria to evaluate analytical performance characteristics (sensitivity, specificity and repeatability) of non-culture assays in three matrices (phosphate-buffered saline, ovarian fluid and kidney tissue). Non-culture assays included polyclonal enzyme-linked immunosorbent assay (ELISA), direct smear fluorescent antibody technique (FAT), membrane-filtration FAT, nested polymerase chain reaction (nested PCR) and three real-time quantitative PCR assays. Injection challenge of specific pathogen-free Chinook salmon, Oncorhynchus tshawytscha (Walbaum), with R. salmoninarum was used to estimate diagnostic sensitivity and specificity. Results did not identify a single assay demonstrating the highest analytical and diagnostic performance characteristics, but revealed strengths and weaknesses of each test.
Relationship between performance variables and baseball ability in youth baseball players.
Nakata, Hiroki; Nagami, Tomoyuki; Higuchi, Takatoshi; Sakamoto, Kiwako; Kanosue, Kazuyuki
2013-10-01
The present study investigated the relationship of performance variables and anthropometric measurements on baseball ability in 164 youth baseball players (age: 6.4-15.7 years). To evaluate their baseball performance, ball speeds in pitching and batting were recorded and kinetic energies of the pitched and hit balls were calculated. To record anthropometric and physical fitness characteristics, height and weight were measured and a battery of physical fitness tests covering standing long jump, side steps, sit-ups, 10-m sprint, trunk flexion, back strength, and grip strengths of both hands were conducted. The results of a multiple regression analysis revealed several significant predictors: age, body mass index (BMI), standing long jump, 10-m sprint, and grip strength for pitched ball kinetic energy and age, BMI, standing long jump, and back strength for hit ball kinetic energy. This study provides scientific evidence that relates certain specific physical performance tests and body characteristics with high achievement in the actual performance of pitching and batting. Youth players, their parents, coaches, and trainers would benefit by addressing these characteristics when planning training programs to improve the baseball performance of youth players.
NASA Technical Reports Server (NTRS)
Gordon, Sanford; Kastner, Michael E
1958-01-01
Theoretical rocket performance for frozen composition during expansion was calculated for liquid methane with several fluorine-oxygen mixtures for a range of pressure ratios and oxidant-fuel ratios. The parameters included are specific impulse, combustion-chamber temperature, nozzle-exit temperature molecular weight, characteristic velocity, coefficient of thrust, ratio of nozzle-exit area to throat area, specific heat at constant pressure, isentropic exponent, viscosity, and thermal conductivity. The maximum calculated value of specific impulse for a chamber pressure of 600 pounds per square inch absolute (40.827atm) and an exit pressure of 1 atmosphere is 315.3 for 79.67 percent fluorine in the oxidant.
Lephart, Scott M; Smoliga, James M; Myers, Joseph B; Sell, Timothy C; Tsai, Yung-Shen
2007-08-01
The purpose of this study was to determine the effects of an 8-week golf-specific exercise program on physical characteristics, swing mechanics, and golf performance. Fifteen trained male golfers (47.2 +/- 11.4 years, 178.8 +/- 5.8 cm, 86.7 +/- 9.0 kg, and 12.1 +/- 6.4 U.S. Golf Association handicap) were recruited. Trained golfers was defined operationally as golfers who play a round of golf at least 2-3 times per week and practice at the driving range at least 2-3 times per week during the regular golf season. Subjects performed a golf-specific conditioning program 3-4 times per week for 8 weeks during the off-season in order to enhance physical characteristics. Pre- and posttraining testing of participants included assessments of strength (torso, shoulder, and hip), flexibility, balance, swing mechanics, and golf performance. Following training, torso rotational strength and hip abduction strength were improved significantly (p < 0.05). Torso, shoulder, and hip flexibility improved significantly in all flexibility measurements taken (p < 0.05). Balance was improved significantly in 3 of 12 measurements, with the remainder of the variables demonstrating a nonsignificant trend for improvement. The magnitude of upper-torso axial rotation was decreased at the acceleration (p = 0.015) and impact points (p =0.043), and the magnitude of pelvis axial rotation was decreased at the top (p = 0.031) and acceleration points (p = 0.036). Upper-torso axial rotational velocity was increased significantly at the acceleration point of the golf swing (p = 0.009). Subjects increased average club velocity (p = 0.001), ball velocity (p = 0.001), carry distance (p = 0.001), and total distance (p = 0.001). These results indicate that a golf-specific exercise program improves strength, flexibility, and balance in golfers. These improvements result in increased upper-torso axial rotational velocity, which results in increased club head velocity, ball velocity, and driving distance.
Accuracy of Screening Mammography Interpretation by Characteristics of Radiologists
Barlow, William E.; Chi, Chen; Carney, Patricia A.; Taplin, Stephen H.; D’Orsi, Carl; Cutter, Gary; Hendrick, R. Edward; Elmore, Joann G.
2011-01-01
Background Radiologists differ in their ability to interpret screening mammograms accurately. We investigated the relationship of radiologist characteristics to actual performance from 1996 to 2001. Methods Screening mammograms (n = 469 512) interpreted by 124 radiologists were linked to cancer outcome data. The radiologists completed a survey that included questions on demographics, malpractice concerns, years of experience interpreting mammograms, and the number of mammograms read annually. We used receiver operating characteristics (ROC) analysis to analyze variables associated with sensitivity, specificity, and the combination of the two, adjusting for patient variables that affect performance. All P values are two-sided. Results Within 1 year of the mammogram, 2402 breast cancers were identified. Relative to low annual interpretive volume (≤1000 mammograms), greater interpretive volume was associated with higher sensitivity (P = .001; odds ratio [OR] for moderate volume [1001–2000] = 1.68, 95% CI = 1.18 to 2.39; OR for high volume [>2000] = 1.89, 95% CI = 1.36 to 2.63). Specificity decreased with volume (OR for 1001–2000 = 0.65, 95% CI = 0.52 to 0.83; OR for more than 2000 = 0.76, 95% CI = 0.60 to 0.96), compared with 1000 or less (P = .002). Greater number of years of experience interpreting mammograms was associated with lower sensitivity (P = .001), but higher specificity (P = .003). ROC analysis using the ordinal BI-RADS interpretation showed an association between accuracy and both previous mammographic history (P = .012) and breast density (P<.001). No association was observed between accuracy and years interpreting mammograms (P = .34) or mammography volume (P = .94), after adjusting for variables that affect the threshold for calling a mammogram positive. Conclusions We found no evidence that greater volume or experience at interpreting mammograms is associated with better performance. However, they may affect sensitivity and specificity, possibly by determining the threshold for calling a mammogram positive. Increasing volume requirements is unlikely to improve overall mammography performance. PMID:15601640
Wong, Elaine M; Ormiston, Margaret E; Haselhuhn, Michael P
2011-12-01
Researchers have theorized that innate personal traits are related to leadership success. Although links between psychological characteristics and leadership success have been well established, research has yet to identify any objective physical traits of leaders that predict organizational performance. In the research reported here, we identified leaders' facial structure as a specific physical trait that correlates with organizational performance. Specifically, we found that firms whose male CEOs have wider faces (relative to facial height) achieve superior financial performance. Decision-making dynamics within a firm's leadership team moderate this effect, such that the relationship between a given CEO's facial measurements and his firm's financial performance is stronger in firms with cognitively simple leadership teams.
Systematic monitoring and evaluation of M7 scanner performance and data quality
NASA Technical Reports Server (NTRS)
Stewart, S.; Christenson, D.; Larsen, L.
1974-01-01
An investigation was conducted to provide the information required to maintain data quality of the Michigan M7 Multispectral scanner by systematic checks on specific system performance characteristics. Data processing techniques which use calibration data gathered routinely every mission have been developed to assess current data quality. Significant changes from past data quality are thus identified and attempts made to discover their causes. Procedures for systematic monitoring of scanner data quality are discussed. In the solar reflective region, calculations of Noise Equivalent Change in Radiance on a permission basis are compared to theoretical tape-recorder limits to provide an estimate of overall scanner performance. M7 signal/noise characteristics are examined.
NASA Technical Reports Server (NTRS)
Rothenberg, Edward A; Ordin, Paul M
1954-01-01
The performance of jet fuel with an oxidant mixture containing 70 percent liquid fluorine and 30 percent liquid oxygen by weight was investigated in a 500-pound-thrust engine operating at a chamber pressure of 300 pounds per square inch absolute. A one-oxidant-on-one-fuel skewed-hole impinging-jet injector was evaluated in a chamber of characteristic length equal to 50 inches. A maximum experimental specific impulse of 268 pound-seconds per pound was obtained at 25 percent fuel, which corresponds to 96 percent of the maximum theoretical specific impulse based on frozen composition expansion. The maximum characteristic velocity obtained was 6050 feet per second at 23 percent fuel, or 94 percent of the theoretical maximum. The average thrust coefficient was 1.38 for the 500-pound thrust combustion-chamber nozzle used, which was 99 percent of the theoretical (frozen) maximum. Mixtures of fluorine and oxygen were found to be self-igniting with jet fuel with fluorine concentrations as low as 4 percent, when low starting propellant flow rated were used.
Physical Performance in Elite Male and Female Team Handball Players.
Wagner, Herbert; Fuchs, Patrick; Fusco, Andrea; Fuchs, Philip; Bell, W Jeffrey; Duvillard, Serge P
2018-06-12
Biological differences between men and women are well known; however, literature-addressing knowledge about the influence of sex to specific and general performance in team handball is almost nonexistent. Consequently, the aim of the study was to assess and compare specific and general physical performance in male and female elite team handball players, to determine if the differences are consequential for general compared to specific physical performance characteristics and the relationship between general and specific physical performance. Twelve male and ten female elite team handball players performed a game based performance test, upper- und lower-body strength and power tests, a sprinting test, and an incremental treadmill-running test. Significant differences (P<.05) between male and female players were found for peak oxygen uptake and total running time during the treadmill test, 30m sprinting time, leg extension strength, trunk and shoulder rotation torque, counter movement jump height as well as offense and defense time, ball velocity and jump height in the game based performance test. An interaction (sex × test) was found for time and oxygen uptake and except shoulder rotation torque and ball velocity in females, we found only a low relationship between specific and general physical performance. The results of the study revealed that male players are heavier, taller, faster, stronger, jump higher and have a better aerobic performance. However, female players performed relatively better in the team handball specific tests compared to the general tests. Our findings also suggest that female players should focus more on strength training.
Computer modeling of heat pipe performance
NASA Technical Reports Server (NTRS)
Peterson, G. P.
1983-01-01
A parametric study of the defining equations which govern the steady state operational characteristics of the Grumman monogroove dual passage heat pipe is presented. These defining equations are combined to develop a mathematical model which describes and predicts the operational and performance capabilities of a specific heat pipe given the necessary physical characteristics and working fluid. Included is a brief review of the current literature, a discussion of the governing equations, and a description of both the mathematical and computer model. Final results of preliminary test runs of the model are presented and compared with experimental tests on actual prototypes.
Non-Conventional Carbon Nanotube Skeleton Reinforced Composites for Space Applications
NASA Astrophysics Data System (ADS)
Hepp, Felicitas; Pfeiffer, E. K.; Pereira, C.; Martins, M.; Liedtke, V.; Macho, C.; Aschenbrenner, O.; Forero, S.; Linke, S.; Masouras, A.; Vavouliotis, A.; Kostopoulos, V.; Wulz, H.-G.; Pambaguian, L.
2014-06-01
Carbon Nanotubes (CNT) embedded in composite materials like CFRP, polymers or ceramics, can improve specific performance characteristics such as e.g. electrical conductivity, mechanical fatigue and crack propagation, mechanical properties, alpha/epsilon values, PIM-reduction, EMC shielding, etc.CNT skeletons, also called Bucky papers and Bucky discs, are macroscopic aggregates of Carbon Nanotubes. These skeletons are used in composites with different matrices, namely metal, ceramic or polymer or directly used in CFRP composites.The aim is to increase the performance of composite space structures by increasing the material characteristics or provide composites with additional sensing abilities like structural health monitoring.
Liquid Engine Design: Effect of Chamber Dimensions on Specific Impulse
NASA Technical Reports Server (NTRS)
Hoggard, Lindsay; Leahy, Joe
2009-01-01
Which assumption of combustion chemistry - frozen or equilibrium - should be used in the prediction of liquid rocket engine performance calculations? Can a correlation be developed for this? A literature search using the LaSSe tool, an online repository of old rocket data and reports, was completed. Test results of NTO/Aerozine-50 and Lox/LH2 subscale and full-scale injector and combustion chamber test results were found and studied for this task. NASA code, Chemical Equilibrium with Applications (CEA) was used to predict engine performance using both chemistry assumptions, defined here. Frozen- composition remains frozen during expansion through the nozzle. Equilibrium- instantaneous chemical equilibrium during nozzle expansion. Chamber parameters were varied to understand what dimensions drive chamber C* and Isp. Contraction Ratio is the ratio of the nozzle throat area to the area of the chamber. L is the length of the chamber. Characteristic chamber length, L*, is the length that the chamber would be if it were a straight tube and had no converging nozzle. Goal: Develop a qualitative and quantitative correlation for performance parameters - Specific Impulse (Isp) and Characteristic Velocity (C*) - as a function of one or more chamber dimensions - Contraction Ratio (CR), Chamber Length (L ) and/or Characteristic Chamber Length (L*). Determine if chamber dimensions can be correlated to frozen or equilibrium chemistry.
ERIC Educational Resources Information Center
Van Biesen, Debbie; Verellen, Joeri; Meyer, Christophe; Mactavish, Jennifer; Van de Vliet, Peter; Vanlandewijck, Yves
2010-01-01
In this study the ability of elite table tennis players with intellectual disability (ID) to adapt their service/return to specific ball spin characteristics was investigated. This was done by examining the performance of 39 players with ID and a reference group of 8 players without ID on a standardized table tennis specific test battery. The…
Mathematics Performance and the Role Played by Affective and Background Factors
ERIC Educational Resources Information Center
Grootenboer, Peter; Hemmings, Brian
2007-01-01
In this article, we report on a study examining those factors which contribute to the mathematics performance of a sample of children aged between 8 and 13 years. The study was designed specifically to consider the potency of a number of mathematical affective factors, as well as background characteristics (viz., gender, ethnicity, and…
Adam Smith, R; Sewell, Sarah L; Giorgio, Todd D
2008-01-01
The development and in vitro performance of a modular nanoscale system capable of specific structural modification by enzymatic activity is described in this work. Due to its small physical size and adaptable characteristics, this system has the potential for utilization in targeted delivery systems and biosensing. Nanoparticle probes were synthesized containing two distinct fluorescent species including a quantum dot base particle and fluorescently labeled cleavable peptide substrate. Activity of these probes was monitored by gel electrophoresis with quantitative cleavage measurements made by fluorometric analysis. The model proximity-activated nanoparticles studied here exhibit significant susceptibility to cleavage by matrix metalloprotease-7 (MMP-7) at physiologically relevant concentrations, with nearly complete cleavage of available substrate molecules after 24 hours. This response is specific to MMP-7 enzyme activity, as cleavage is completely inhibited with the addition of EDTA. Utilization of enzyme-specific modification is a sensitive approach with broad applications for targeted therapeutics and biosensing. The versatility of this nanoparticle system is highlighted in its modular design, as it has the capability to integrate characteristics for detection, biosensing, targeting, and payload delivery into a single, multifunctional nanoparticle structure. PMID:18488420
Effects of aggregate angularity on mix design characteristics and pavement performance.
DOT National Transportation Integrated Search
2009-12-01
This research targeted two primary purposes: to estimate current aggregate angularity test methods and to evaluate current : aggregate angularity requirements in the Nebraska asphalt mixture/pavement specification. To meet the first research : object...
Self-shielded electron linear accelerators designed for radiation technologies
NASA Astrophysics Data System (ADS)
Belugin, V. M.; Rozanov, N. E.; Pirozhenko, V. M.
2009-09-01
This paper describes self-shielded high-intensity electron linear accelerators designed for radiation technologies. The specific property of the accelerators is that they do not apply an external magnetic field; acceleration and focusing of electron beams are performed by radio-frequency fields in the accelerating structures. The main characteristics of the accelerators are high current and beam power, but also reliable operation and a long service life. To obtain these characteristics, a number of problems have been solved, including a particular optimization of the accelerator components and the application of a variety of specific means. The paper describes features of the electron beam dynamics, accelerating structure, and radio-frequency power supply. Several compact self-shielded accelerators for radiation sterilization and x-ray cargo inspection have been created. The introduced methods made it possible to obtain a high intensity of the electron beam and good performance of the accelerators.
Hubbard, Rebecca A; Benjamin-Johnson, Rhondee; Onega, Tracy; Smith-Bindman, Rebecca; Zhu, Weiwei; Fenton, Joshua J
2015-01-15
Quality assessment is critical for healthcare reform, but data sources are lacking for measurement of many important healthcare outcomes. With over 49 million people covered by Medicare as of 2010, Medicare claims data offer a potentially valuable source that could be used in targeted health care quality improvement efforts. However, little is known about the operating characteristics of provider profiling methods using claims-based outcome measures that may estimate provider performance with error. Motivated by the example of screening mammography performance, we compared approaches to identifying providers failing to meet guideline targets using Medicare claims data. We used data from the Breast Cancer Surveillance Consortium and linked Medicare claims to compare claims-based and clinical estimates of cancer detection rate. We then demonstrated the performance of claim-based estimates across a broad range of operating characteristics using simulation studies. We found that identification of poor performing providers was extremely sensitive to algorithm specificity, with no approach identifying more than 65% of poor performing providers when claims-based measures had specificity of 0.995 or less. We conclude that claims have the potential to contribute important information on healthcare outcomes to quality improvement efforts. However, to achieve this potential, development of highly accurate claims-based outcome measures should remain a priority. Copyright © 2014 John Wiley & Sons, Ltd.
Patient-centered Medical Home Capability and Clinical Performance in HRSA-supported Health Centers
Shi, Leiyu; Lock, Diana C.; Lee, De-Chih; Lebrun-Harris, Lydie A.; Chin, Marshall H.; Chidambaran, Preeta; Nocon, Robert S.; Zhu, Jinsheng; Sripipatana, Alek
2015-01-01
Objectives To evaluate the relationship between Patient-centered Medical Home (PCMH) model adoption in health centers (HCs) and clinical performance measures and to determine if adoption of PCMH characteristics is associated with better clinical performance. Research Design Data came from the Health Resources and Services Administration’s 2009 Uniform Data System and the 2009 Commonwealth Fund National Survey of Federally Qualified Health Centers. Clinical performance measures included 2 process measures (childhood immunization and cervical cancer screening) and 2 outcome measures (hypertension control and diabetes control). Total and subscale PCMH scores were regressed on the clinical performance measures, adjusting for patient, provider, financial, and institutional characteristics. Results The findings showed different directional relationships, with some PCMH domains (care management, test/referral tracking, quality improvement, and external coordination) showing little or no effect on outcome measures of interest, 1 domain (access/communication) associated with improved outcomes, and 1 domain (patient tracking/registry) associated with worse outcomes. Conclusions This study is among the first to examine the association between PCMH transformation and clinical performance in HCs, providing an understanding of the impact of PCMH adoption within safety-net settings. The mixed results highlight the importance of examining relationships between specific PCMH domains and specific clinical quality measures, in addition to analyzing overall PCMH scores which could yield distorted findings. PMID:25793267
Machida, Yuta; Yamamoto, Takahiko; Koshiji, Kohji
2013-01-01
Human body communication (HBC) is a new communication technology that has presented potential applications in health care and elderly support systems in recent years. In this study, which is focused on a wearable transmitter and receiver for HBC in a body area network (BAN), we performed electromagnetic field analysis and simulation using the finite difference time domain (FDTD) method with various models of the human body. Further we redesigned a number of impedance-matched electrodes to allow transmission without stubs or transformers. The specific absorption rate (SAR) and transmission characteristics S21 of these electrode structures were compared for several models.
NASA Technical Reports Server (NTRS)
Syed, S. A.; Chiappetta, L. M.
1985-01-01
A methodological evaluation for two-finite differencing schemes for computer-aided gas turbine design is presented. The two computational schemes include; a Bounded Skewed Finite Differencing Scheme (BSUDS); and a Quadratic Upwind Differencing Scheme (QSDS). In the evaluation, the derivations of the schemes were incorporated into two-dimensional and three-dimensional versions of the Teaching Axisymmetric Characteristics Heuristically (TEACH) computer code. Assessments were made according to performance criteria for the solution of problems of turbulent, laminar, and coannular turbulent flow. The specific performance criteria used in the evaluation were simplicity, accuracy, and computational economy. It is found that the BSUDS scheme performed better with respect to the criteria than the QUDS. Some of the reasons for the more successful performance BSUDS are discussed.
Gender Differences in Physical Performance Characteristics of Elite Surfers.
Parsonage, Joanna R; Secomb, Josh L; Tran, Tai T; Farley, Oliver R L; Nimphius, Sophia; Lundgren, Lina; Sheppard, Jeremy M
2017-09-01
Parsonage, JR, Secomb, JL, Tran, TT, Farley, ORL, Nimphius, S, Lundgren, L, and Sheppard, JM. Gender differences in physical performance characteristics of elite surfers. J Strength Cond Res 31(9): 2417-2422, 2017-The purpose of this study was to describe and compare the gender differences in physical performance characteristics of elite surfers. Twenty competitive female surfers (CFS) and 20 competitive male surfers (CMS) performed a battery of physical performance tests: squat jump (SJ), isometric midthigh pull (IMTP), 15-m sprint paddle, and 400-m endurance paddle during a single testing session. All performance measures were significantly different between CFS and CMS (p < 0.01). Specifically, CMS produced greater peak force production (28.5%) and jumped higher (27.7%) in the SJ and produced greater normalized peak force during the IMTP (18.9%) compared with CFS. For paddling performance, CMS were faster over 5, 10, and 15 m (12.4%, 9.7%, and 10.9%), possessed a higher peak paddling velocity (11.3%), and recorded faster paddle times over 400 m (11.8%). The results of this study suggest that CMS exhibit superior physical performance characteristics than CFS, in relation to both the lower and upper body. Strength and conditioning practitioners should therefore implement a structured and periodized program to facilitate strength qualities that underpin surfing performance for all participants, but as highlighted in the current investigation, female surfers may have a greater window for adaptation and therefore vast benefit of targeting their underdeveloped physical qualities.
Lacbawan, Felicitas L; Weck, Karen E; Kant, Jeffrey A; Feldman, Gerald L; Schrijver, Iris
2012-01-01
The number of clinical laboratories introducing various molecular tests to their existing test menu is continuously increasing. Prior to offering a US Food and Drug Administration-approved test, it is necessary that performance characteristics of the test, as claimed by the company, are verified before the assay is implemented in a clinical laboratory. To provide an example of the verification of a specific qualitative in vitro diagnostic test: cystic fibrosis carrier testing using the Luminex liquid bead array (Luminex Molecular Diagnostics, Inc, Toronto, Ontario). The approach used by an individual laboratory for verification of a US Food and Drug Administration-approved assay is described. Specific verification data are provided to highlight the stepwise verification approach undertaken by a clinical diagnostic laboratory. Protocols for verification of in vitro diagnostic assays may vary between laboratories. However, all laboratories must verify several specific performance specifications prior to implementation of such assays for clinical use. We provide an example of an approach used for verifying performance of an assay for cystic fibrosis carrier screening.
Fujita, Takaaki; Sato, Atsushi; Tsuchiya, Kenji; Ohashi, Takuro; Yamane, Kazuhiro; Yamamoto, Yuichi; Iokawa, Kazuaki; Ohira, Yoko; Otsuki, Koji; Tozato, Fusae
2017-12-01
This study aimed to elucidate the relationship between grooming performance of stroke patients and various motor and cognitive functions and to examine the cognitive and physical functional standards required for grooming independence. We retrospectively analyzed the data of 96 hospitalized patients with first stroke in a rehabilitation hospital ward. Logistic regression analysis and receiver operating characteristic curves were used to investigate the related cognitive and motor functions with grooming performance and to calculate the cutoff values for independence and supervision levels in grooming. For analysis between the independent and supervision-dependent groups, the only item with an area under the curve (AUC) of .9 or higher was the Berg Balance Scale, and the calculated cutoff value was 41/40 (sensitivity, 83.6%; specificity, 87.8%). For analysis between the independent-supervision and dependent groups, the items with an AUC of .9 or higher were the Simple Test for Evaluating Hand Function (STEF) on the nonaffected side, Vitality Index (VI), and FIM ® cognition. The cutoff values were 68/67 for the STEF (sensitivity, 100%; specificity, 72.2%), 9/8 points for the VI (sensitivity, 92.3%; specificity, 88.9%), and 23/22 points for FIM ® cognition (sensitivity, 91.0%; specificity, 88.9%). Our results suggest that upper-extremity functions on the nonaffected side, motivation, and cognitive functions are particularly important to achieve the supervision level and that balance is important to reach the independence level. The effective improvement of grooming performance is possible by performing therapeutic or compensatory intervention on functions that have not achieved these cutoff values. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Kim, Daniel J; Francispragasam, Mario; Docherty, Gavin; Silver, Byron; Prager, Ross; Lee, Donna; Maberley, David
2018-05-18
Previous studies of point of care ultrasound (POCUS) have reported high sensitivities and specificities for retinal detachment (RD). Our primary objective was to assess the test characteristics of POCUS performed by a large heterogeneous group of emergency physicians (EPs) for the diagnosis of RD. This was a prospective diagnostic test assessment of POCUS performed by EPs with varying ultrasound experience on a convenience sample of emergency department (ED) patients presenting with flashes or floaters in one or both eyes. After standard ED assessment, EPs performed an ocular POCUS scan targeted to detect the presence or absence of RD. After completing their ED visit, all patients were assessed by a retina specialist who was blinded to the results of the POCUS scan. We calculated sensitivity and specificity with associated exact binomial confidence intervals (CI) using the retina specialist's final diagnosis as the reference standard. A total of 30 EPs enrolled 115 patients, with median age of 60 years and 64% female. The retina specialist diagnosed RD in 16 (14%) cases. The sensitivity and specificity of POCUS for detecting RD was 75% (95% CI 48%-93%) and 94% (95% CI 87%-98%), respectively. The positive likelihood ratio was 12.4 (95% CI 5.4-28.3), and negative likelihood ratio was 0.27 (95% CI 0.11-0.62). A large heterogeneous group of EPs can perform POCUS with high specificity but only intermediate sensitivity for RD. A negative POCUS scan in the ED performed by a heterogeneous group of providers after a one-hour POCUS didactic is not sufficiently sensitive to rule out RD in a patient with new onset flashes or floaters. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Impact of Breast Reader Assessment Strategy on mammographic radiologists' test reading performance.
Suleiman, Wasfi I; Rawashdeh, Mohammad A; Lewis, Sarah J; McEntee, Mark F; Lee, Warwick; Tapia, Kriscia; Brennan, Patrick C
2016-06-01
The detection of breast cancer is somewhat limited by human factors, and thus there is a need to improve reader performance. This study assesses whether radiologists who regularly undertake the education in the form of the Breast Reader Assessment Strategy (BREAST) demonstrate any changes in mammography interpretation performance over time. In 2011, 2012 and 2013, 14 radiologists independently assessed a year-specific BREAST mammographic test-set. Radiologists read a different single test-set once each year, with each comprising 60 digital mammogram cases. Radiologists marked the location of suspected lesions without computer-aided diagnosis (CAD) and assigned a confidence rating of 2 for benign and 3-5 for malignant lesions. The mean sensitivity, specificity, location sensitivity, JAFROC FOM and ROC AUC were calculated. A Kruskal-Wallis test was used to compare the readings for the 14 radiologists across the 3 years. Wilcoxon signed rank test was used to assess comparison between pairs of years. Relationships between changes in performance and radiologist characteristics were examined using a Spearman's test. Significant increases were noted in mean sensitivity (P = 0.01), specificity (P = 0.01), location sensitivity (P = 0.001) and JAFROC FOM (P = 0.001) between 2011 and 2012. Between 2012 and 2013, significant improvements were noted in mean sensitivity (P = 0.003), specificity (P = 0.002), location sensitivity (P = 0.02), JAFROC FOM (P = 0.005) and ROC AUC (P = 0.008). No statistically significant correlations were shown between the levels of improvement and radiologists' characteristics. Radiologists' who undertake the BREAST programme demonstrate significant improvements in test-set performance during a 3-year period, highlighting the value of ongoing education through the use of test-set. © 2016 The Royal Australian and New Zealand College of Radiologists.
Bravi, Riccardo; Del Tongo, Claudia; Cohen, Erez James; Dalle Mura, Gabriele; Tognetti, Alessandro; Minciacchi, Diego
2014-06-01
The ability to perform isochronous movements while listening to a rhythmic auditory stimulus requires a flexible process that integrates timing information with movement. Here, we explored how non-temporal and temporal characteristics of an auditory stimulus (presence, interval occupancy, and tempo) affect motor performance. These characteristics were chosen on the basis of their ability to modulate the precision and accuracy of synchronized movements. Subjects have participated in sessions in which they performed sets of repeated isochronous wrist's flexion-extensions under various conditions. The conditions were chosen on the basis of the defined characteristics. Kinematic parameters were evaluated during each session, and temporal parameters were analyzed. In order to study the effects of the auditory stimulus, we have minimized all other sensory information that could interfere with its perception or affect the performance of repeated isochronous movements. The present study shows that the distinct characteristics of an auditory stimulus significantly influence isochronous movements by altering their duration. Results provide evidence for an adaptable control of timing in the audio-motor coupling for isochronous movements. This flexibility would make plausible the use of different encoding strategies to adapt audio-motor coupling for specific tasks.
Anthropometric, physiological and performance characteristics of elite team-handball players.
Chaouachi, Anis; Brughelli, Matt; Levin, Gregory; Boudhina, Nahla Ben Brahim; Cronin, John; Chamari, Karim
2009-01-15
The objective of this study was to provide anthropometric, physiological, and performance characteristics of an elite international handball team. Twenty-one elite handball players were tested and categorized according to their playing positions (goalkeepers, backs, pivots, and wings). Testing consisted of anthropometric and physiological measures of height, body mass, percentage body fat and endurance (VO(2max)), performance measures of speed (5, 10, and 30 m), strength (bench press and squat), unilateral and bilateral horizontal jumping ability, and a 5-jump horizontal test. Significant differences were found between player positions for some anthropometric characteristics (height and percentage body fat) but not for the physiological or performance characteristics. Strong correlations were noted between single leg horizontal jumping distances with 5-, 10-, and 30-m sprint times (r = 0.51-0.80; P < 0.01). The best predictors of sprint times were single leg horizontal jumping with the dominant leg and the distance measured for the 5-jump test, which when combined accounted for 72% of the common variance associated with sprint ability. In conclusion, performance abilities between positions in elite team-handball players appear to be very similar. Single leg horizontal jumping distance could be a specific standardized test for predicting sprinting ability in elite handball players.
Analytical description of the modern steam automobile
NASA Technical Reports Server (NTRS)
Peoples, J. A.
1974-01-01
The sensitivity of operating conditions upon performance of the modern steam automobile is discussed. The word modern has been used in the title to indicate that emphasis is upon miles per gallon rather than theoretical thermal efficiency. This has been accomplished by combining classical power analysis with the ideal Pressure-Volume diagram. Several parameters are derived which characterize performance capability of the modern steam car. The report illustrates that performance is dictated by the characteristics of the working medium, and the supply temperature. Performance is nearly independent of pressures above 800 psia. Analysis techniques were developed specifically for reciprocating steam engines suitable for automotive application. Specific performance charts have been constructed on the basis of water as a working medium. The conclusions and data interpretation are therefore limited within this scope.
Antisaccade performance of 1,273 men: effects of schizotypy, anxiety, and depression.
Smyrnis, Nikolaos; Evdokimidis, Ioannis; Stefanis, Nicholas C; Avramopoulos, Dimitrios; Constantinidis, Theodoros S; Stavropoulos, Alexios; Stefanis, Costas N
2003-08-01
A total of 1,273 conscripts of the Greek Air Force performed antisaccades and completed self-reporting questionnaires measuring schizotypy and current state-dependent psychopathology. Only 1.0% of variability in antisaccade performance indices was related to psychometric scores in the population and could be attributed more to current state-dependent symptoms such as anxiety rather than to schizotypy. In contrast, a specific increase of error rate and response latency variability and a high correlation of these 2 variables was observed in a group with very high schizotypy scores. This effect was independent of anxiety and depression, suggesting that a specific group of psychosis-prone individuals has a characteristic deviance in antisaccade performance that is not present in the general population.
Theoretical performance of liquid hydrogen and liquid fluorine as a rocket propellant
NASA Technical Reports Server (NTRS)
Gordon, Sanford; Huff, Vearl N
1953-01-01
Theoretical values of performance parameters for liquid hydrogen and liquid fluorine as a rocket propellant were calculated on the assumption of equilibrium composition during the expansion process for a wide range of fuel-oxidant and expansion ratios. The parameters included were specific impulse, combustion-chamber temperature, nozzle-exit temperature, equilibrium composition, mean molecular weight, characteristic velocity, coefficient of thrust, ration of nozzle-exit area to throat area, specific heat at constant pressure, coefficient of viscosity, and coefficient of thermal conductivity. The maximum value of specific impulse was 364.6 pound-seconds per pound for a chamber pressure of 300 pounds per square inch absolute (20.41 atm) and an exit pressure of 1 atmosphere.
NASA Technical Reports Server (NTRS)
Gordon, Sanford; Zeleznik, Frank J.; Huff, Vearl N.
1959-01-01
A general computer program for chemical equilibrium and rocket performance calculations was written for the IBM 650 computer with 2000 words of drum storage, 60 words of high-speed core storage, indexing registers, and floating point attachments. The program is capable of carrying out combustion and isentropic expansion calculations on a chemical system that may include as many as 10 different chemical elements, 30 reaction products, and 25 pressure ratios. In addition to the equilibrium composition, temperature, and pressure, the program calculates specific impulse, specific impulse in vacuum, characteristic velocity, thrust coefficient, area ratio, molecular weight, Mach number, specific heat, isentropic exponent, enthalpy, entropy, and several thermodynamic first derivatives.
Theoretical performance of liquid ammonia and liquid fluorine as a rocket propellant
NASA Technical Reports Server (NTRS)
Gordon, Sanford; Huff, Vearl N
1953-01-01
Theoretical values of performance parameters for liquid ammonia and liquid fluorine as a rocket propellant were calculated on the assumption of equilibrium composition during the expansion process for a wide range of fuel-oxidant and expansion ratios. The parameters included were specific impulse, combustion chamber temperature, nozzle-exit temperature, equilibrium composition, mean molecular weight, characteristic velocity, coefficient of thrust, ratio of nozzle-exit area to throat area, specific heat at constant pressure, coefficient of viscosity, and coefficient of thermal conductivity. The maximum value of specific impulse was 311.5 pound-seconds per pound for a chamber pressure of 300 pounds per square inch absolute (20.41 atm) and an exit pressure of 1 atmosphere.
Zou, Lingyun; Wang, Zhengzhi; Huang, Jiaomin
2007-12-01
Subcellular location is one of the key biological characteristics of proteins. Position-specific profiles (PSP) have been introduced as important characteristics of proteins in this article. In this study, to obtain position-specific profiles, the Position Specific Iterative-Basic Local Alignment Search Tool (PSI-BLAST) has been used to search for protein sequences in a database. Position-specific scoring matrices are extracted from the profiles as one class of characteristics. Four-part amino acid compositions and 1st-7th order dipeptide compositions have also been calculated as the other two classes of characteristics. Therefore, twelve characteristic vectors are extracted from each of the protein sequences. Next, the characteristic vectors are weighed by a simple weighing function and inputted into a BP neural network predictor named PSP-Weighted Neural Network (PSP-WNN). The Levenberg-Marquardt algorithm is employed to adjust the weight matrices and thresholds during the network training instead of the error back propagation algorithm. With a jackknife test on the RH2427 dataset, PSP-WNN has achieved a higher overall prediction accuracy of 88.4% rather than the prediction results by the general BP neural network, Markov model, and fuzzy k-nearest neighbors algorithm on this dataset. In addition, the prediction performance of PSP-WNN has been evaluated with a five-fold cross validation test on the PK7579 dataset and the prediction results have been consistently better than those of the previous method on the basis of several support vector machines, using compositions of both amino acids and amino acid pairs. These results indicate that PSP-WNN is a powerful tool for subcellular localization prediction. At the end of the article, influences on prediction accuracy using different weighting proportions among three characteristic vector categories have been discussed. An appropriate proportion is considered by increasing the prediction accuracy.
High subsonic flow tests of a parallel pipe followed by a large area ratio diffuser
NASA Technical Reports Server (NTRS)
Barna, P. S.
1975-01-01
Experiments were performed on a pilot model duct system in order to explore its aerodynamic characteristics. The model was scaled from a design projected for the high speed operation mode of the Aircraft Noise Reduction Laboratory. The test results show that the model performed satisfactorily and therefore the projected design will most likely meet the specifications.
SnO2 Nanostructures: Effect of Processing Parameters on Their Structural and Functional Properties
NASA Astrophysics Data System (ADS)
Dontsova, Tetiana A.; Nagirnyak, Svitlana V.; Zhorov, Vladyslav V.; Yasiievych, Yuriy V.
2017-05-01
Zero- and 1D (one-dimensional) tin (IV) oxide nanostructures have been synthesized by thermal evaporation method, and a comparison of their morphology, crystal structure, sorption properties, specific surface area, as well as electrical characteristics has been performed. Synthesized SnO2 nanomaterials were studied by X-ray diffraction, scanning and transmission electron microscopy (SEM and TEM), N2 sorption/desorption technique, IR spectroscopy and, in addition, their current-voltage characteristics have also been measured. The single crystalline structures were obtained both in case of 0D (zero-dimensional) SnO2 powders and in case of 0D nanofibers, as confirmed by electron diffraction of TEM. It was found that SnO2 synthesis parameters significantly affect materials' properties by contributing to the difference in morphology, texture formation, changes in IR spectra of 1D structure as compared to 0D powders, increases in the specific surface area of nanofibers, and the alteration of current-voltage characteristics 0D and 1D SnO2 nanostructures. It was established that gas sensors utilizing of 1D nanofibers significantly outperform those based on 0D powders by providing higher specific surface area and ohmic I-V characteristics.
Schenk, Jeannette M; Hunter-Merrill, Rachel; Zheng, Yingye; Etzioni, Ruth; Gulati, Roman; Tangen, Catherine; Thompson, Ian M; Kristal, Alan R
2013-09-01
Although surrogate measures of benign prostatic hyperplasia (BPH) are often used in epidemiologic studies, their performance characteristics are unknown. Using data from the Prostate Cancer Prevention Trial (n = 5,986), we evaluated prostate-specific antigen (PSA), International Prostate Symptom Score (IPSS), and their rates of change as predictors of incident BPH. BPH (n = 842 cases) was defined as medical or surgical treatment or at least 2 IPSS of 15 or higher. Proportional hazards models were used to measure the associations of baseline PSA, IPSS, and their velocities over 2 years with BPH risk, and time-dependent receiver-operating characteristic curves were used to measure their discriminatory performance. Unit increases in PSA, IPSS, and IPSS velocity were associated with 34%, 35%, and 29% (all P < 0.001) increases in BPH risk, respectively. The areas under the receiver-operating characteristic curves were significantly greater than 0.5 for PSA (0.58, 95% confidence interval (CI): 0.56, 0.60), IPSS (0.77, 95% CI: 0.75, 0.78), and IPSS velocity (0.63, 95% CI: 0.61, 0.65); however there were no cut points at which sensitivity and specificity were both above 75%. We concluded that moderate elevations in PSA, IPSS, or their rates of change should not be used as surrogate measures of incident BPH.
Adachi, Noritaka; Yamaguchi, Daisuke; Watanabe, Akiyuki; Miura, Narumi; Sunaga, Seiji; Oishi, Hitoshi; Hashimoto, Michiko; Oishi, Takatsugu; Iwamoto, Masaki; Hanada, Hirofumi; Kubo, Masanori; Onishi, Akira
2014-04-24
The objective of this study was to examine the health and meat production of cloned sows and their progenies in order to demonstrate the application of somatic cell cloning to the pig industry. This study compared the growth, reproductive performance, carcass characteristics and meat quality of Landrace cloned sows, F1 progenies and F2 progenies. We measured their body weight, growth rate and feed conversion and performed a pathological analysis of their anatomy to detect abnormalities. Three of the five cloned pigs were used for a growth test. Cloned pigs grew normally and had characteristics similar to those of the control purebred Landrace pigs. Two cloned gilts were bred with a Landrace boar and used for a progeny test. F1 progenies had characteristics similar to those of the controls. Two of the F1 progeny gilts were bred with a Duroc or Large White boar and used for the progeny test. F2 progenies grew normally. There were no biological differences in growth, carcass characteristics and amino acid composition among cloned sows, F1 progenies, F2 progenies and conventional pigs. The cloned sows and F1 progenies showed normal reproductive performance. No specific abnormalities were observed by pathological analysis, with the exception of periarteritis in the F1 progenies. All pigs had a normal karyotype. These results demonstrate that cloned female pigs and their progenies have similar growth, reproductive performance and carcass quality characteristics and that somatic cell cloning could be a useful technique for conserving superior pig breeds in conventional meat production.
ADACHI, Noritaka; YAMAGUCHI, Daisuke; WATANABE, Akiyuki; MIURA, Narumi; SUNAGA, Seiji; OISHI, Hitoshi; HASHIMOTO, Michiko; OISHI, Takatsugu; IWAMOTO, Masaki; HANADA, Hirofumi; KUBO, Masanori; ONISHI, Akira
2014-01-01
The objective of this study was to examine the health and meat production of cloned sows and their progenies in order to demonstrate the application of somatic cell cloning to the pig industry. This study compared the growth, reproductive performance, carcass characteristics and meat quality of Landrace cloned sows, F1 progenies and F2 progenies. We measured their body weight, growth rate and feed conversion and performed a pathological analysis of their anatomy to detect abnormalities. Three of the five cloned pigs were used for a growth test. Cloned pigs grew normally and had characteristics similar to those of the control purebred Landrace pigs. Two cloned gilts were bred with a Landrace boar and used for a progeny test. F1 progenies had characteristics similar to those of the controls. Two of the F1 progeny gilts were bred with a Duroc or Large White boar and used for the progeny test. F2 progenies grew normally. There were no biological differences in growth, carcass characteristics and amino acid composition among cloned sows, F1 progenies, F2 progenies and conventional pigs. The cloned sows and F1 progenies showed normal reproductive performance. No specific abnormalities were observed by pathological analysis, with the exception of periarteritis in the F1 progenies. All pigs had a normal karyotype. These results demonstrate that cloned female pigs and their progenies have similar growth, reproductive performance and carcass quality characteristics and that somatic cell cloning could be a useful technique for conserving superior pig breeds in conventional meat production. PMID:24492641
What Performance Characteristics Determine Elite Versus Nonelite Athletes in the Same Sport?
Lorenz, Daniel S.; Reiman, Michael P.; Lehecka, B.J.; Naylor, Andrew
2013-01-01
Context: There are significant data comparing elite and nonelite athletes in anaerobic field and court sports as well as endurance sports. This review delineates specific performance characteristics in the elite athlete and may help guide rehabilitation. Evidence Acquisition: A Medline search from April 1982 to April 2012 was undertaken for articles written in English. Additional references were accrued from reference lists of research articles. Results: In the anaerobic athlete, maximal power production was consistently correlated to elite performance. Elite performance in the endurance athlete is more ambiguous, however, and appears to be related to the dependent variable investigated in each individual study. Conclusion: In anaerobic field and court sport athletes, maximal power output is most predictive of elite performance. In the endurance athlete, however, it is not as clear. Elite endurance athletes consistently test higher than nonelite athletes in running economy, anaerobic threshold, and VO2max. PMID:24427430
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Holak; Lim, Youbong; Choe, Wonho, E-mail: wchoe@kaist.ac.kr
2014-10-06
Plasma plume and thruster performance characteristics associated with multiply charged ions in a cylindrical type Hall thruster (CHT) and an annular type Hall thruster are compared under identical conditions such as channel diameter, channel depth, propellant mass flow rate. A high propellant utilization in a CHT is caused by a high ionization rate, which brings about large multiply charged ions. Ion currents and utilizations are much different due to the presence of multiply charged ions. A high multiply charged ion fraction and a high ionization rate in the CHT result in a higher specific impulse, thrust, and discharge current.
Adaptability and stability of soybean genotypes in off-season cultivation.
Batista, R O; Hamawaki, R L; Sousa, L B; Nogueira, A P O; Hamawaki, O T
2015-08-14
The oil and protein contents of soybean grains are important quantitative traits for use in breeding. However, few breeding programs perform selection based on these traits in different environments. This study assessed the adaptability and stability of 14 elite early soybean breeding lines in off-season cultivation with respect to yield, and oil and protein contents. A range of statistical methods was applied and these analyses indicated that for off-season cultivation, the lines UFUS 5 and UFUS 10 could be recommended due to their superior performance in grain yield, oil content, and specific adaptability to unfavorable environments along with high stability in these characteristics. Also recommended were UFUS 06, which demonstrated superior performance in all three tested characteristics and showed adaptation to favorable environments, and UFUS 13, which showed high adaptability and stability and a superior performance for protein content.
Performance and optimization of a derated ion thruster for auxiliary propulsion
NASA Technical Reports Server (NTRS)
Patterson, Michael J.; Foster, John E.
1991-01-01
The characteristics and implications of use of a derated ion thruster for north-south stationkeeping (NSSK) propulsion are discussed. A derated thruster is a 30 cm diameter primary propulsion ion thruster operated at highly throttled conditions appropriate to NSSK functions. The performance characteristics of a 30 cm ion thruster are presented, emphasizing throttled operation at low specific impulse and high thrust-to-power ratio. Performance data and component erosion are compared to other NSSK ion thrusters. Operations benefits derived from the performance advantages of the derated approach are examined assuming an INTELSAt 7-type spacecraft. Minimum ground test facility pumping capabilities required to maintain facility enhanced accelerator grid erosion at acceptable levels in a lifetest are quantified as a function of thruster operating condition. Approaches to reducing the derated thruster mass and volume are also discussed.
NASA Astrophysics Data System (ADS)
Musa, Omer; Weixuan, Li; Xiong, Chen; Lunkun, Gong; Wenhe, Liao
2018-07-01
Solid-fuel ramjet converts thermal energy of combustion products to a forward thrust without using any moving parts. Normally, it uses air intake system to compress the incoming air without swirler. A new design of swirler has been proposed and used in the current work. In this paper, a series of firing tests have been carried out to investigate the impact of using swirl flow on regression rate, combustion characteristics, and performance of solid-fuel ramjet engines. The influences of swirl intensity, solid fuel port diameter, and combustor length were studied and varied independently. A new technique for determining the time and space averaged regression rate of high-density polyethylene solid fuel surface after experiments has been proposed based on the laser scan technique. A code has been developed to reconstruct the data from the scanner and then used to obtain the three-dimensional distribution of the regression rate. It is shown that increasing swirl number increases regression rate, thrust, and characteristic velocity, and, decreases air-fuel ratio, corner recirculation zone length, and specific impulse. Using swirl flow enhances the flame stability meanwhile negatively affected on ignition process and specific impulse. Although a significant reduction of combustion chamber length can be achieved when swirl flow is used. Power fitting correlation for average regression rate was developed taking into account the influence of swirl number. Furthermore, varying port diameter and combustor length were found to have influences on regression rate, combustion characteristics and performance of solid-fuel ramjet.
Altitude Performance Characteristics of Tail-pipe Burner with Variable-area Exhaust Nozzle
NASA Technical Reports Server (NTRS)
Jansen, Emmert T; Thorman, H Carl
1950-01-01
An investigation was conducted in the NACA Lewis altitude wind tunnel to determine effect of altitude and flight Mach number on performance of tail-pipe burner equipped with variable-area exhaust nozzle and installed on full-scale turbojet engine. At a given flight Mach number, with constant exhaust-gas and turbine-outlet temperatures, increasing altitude lowered the tail-pipe combustion efficiency and raised the specific fuel consumption while the augmented thrust ratio remained approximately constant. At a given altitude, increasing flight Mach number raised the combustion efficiency and augmented thrust ratio and lowered the specific fuel consumption.
Electrocardiogram transmission - The state of the art.
NASA Technical Reports Server (NTRS)
Firstenberg, A.; Huston, S. W.; Olsen, D. E.; Hahn, P. M.
1971-01-01
A comparative analysis of available clinical EKG telemetry systems was conducted. Although present day electrocardiogram diagnosis requires a high degree of measurement accuracy, there exists wide variations in the performance characteristics of the various telemeters marketed today necessitating careful consideration of specifications prior to procurement. The authors have endeavored to provide the physicians with a clear understanding, in terms of the effects on the electrocardiogram, of the factors he must evaluate in order to ensure high fidelity EKG reproduction. A tabulation of comparative parameter values for each unit obtained from manufacturers' specifications and substantiated by standardized performance tests conducted in our laboratory is presented.
Shiha, G; Seif, S; Eldesoky, A; Elbasiony, M; Soliman, R; Metwally, A; Zalata, K; Mikhail, N
2017-05-01
A simple non-invasive score (Fibrofast, FIB-5) was developed using five routine laboratory tests (ALT, AST, alkaline phosphatase, albumin and platelets count) for the detection of significant hepatic fibrosis in patients with chronic hepatitis C. The FIB-4 index is a non-invasive test for the assessment of liver fibrosis, and a score of ≤1.45 enables the correct identification of patients who have non-significant (F0-1) from significant fibrosis (F2-4), and could avoid liver biopsy. The aim of this study was to compare the performance characteristics of FIB-5 and FIB-4 to differentiate between non-significant and significant fibrosis. A cross-sectional study included 604 chronic HCV patients. All liver biopsies were scored using the METAVIR system. Both FIB-5 and FIB-4 scores were measured and the performance characteristics were calculated using the ROC curve. The performance characteristics of FIB-5 at ≥7.5 and FIB-4 at ≤1.45 for the differentiation between non-significant fibrosis and significant fibrosis were: specificity 94.4%, PPV 85.7%, and specificity 54.9%, PPV 55.7% respectively. FIB-5 score at the new cutoff is superior to FIB-4 index for the differentiation between non-significant and significant fibrosis.
Thermodynamic Analysis of Dual-Mode Scramjet Engine Operation and Performance
NASA Technical Reports Server (NTRS)
Riggins, David; Tacket, Regan; Taylor, Trent; Auslender, Aaron
2006-01-01
Recent analytical advances in understanding the performance continuum (the thermodynamic spectrum) for air-breathing engines based on fundamental second-law considerations have clarified scramjet and ramjet operation, performance, and characteristics. Second-law based analysis is extended specifically in this work to clarify and describe the performance characteristics for dual-mode scramjet operation in the mid-speed range of flight Mach 4 to 7. This is done by a fundamental investigation of the complex but predictable interplay between heat release and irreversibilities in such an engine; results demonstrate the flow and performance character of the dual mode regime and of dual mode transition behavior. Both analytical and computational (multi-dimensional CFD) studies of sample dual-mode flow-fields are performed in order to demonstrate the second-law capability and performance and operability issues. The impact of the dual-mode regime is found to be characterized by decreasing overall irreversibility with increasing heat release, within the operability limits of the system.
Musculoskeletal, biomechanical, and physiological gender differences in the US military.
Allison, Katelyn F; Keenan, Karen A; Sell, Timothy C; Abt, John P; Nagai, Takashi; Deluzio, Jennifer; McGrail, Mark; Lephart, Scott M
2015-01-01
The repeal of the Direct Ground Combat Assignment Rule has renewed focus on examining performance capabilities of female military personnel and their ability to occupy previously restricted military occupational specialties. Previous research has revealed female Soldiers suffer a greater proportion of musculoskeletal injuries compared to males, including a significantly higher proportion of lower extremity, knee, and overuse injuries. Potential differences may also exist in musculoskeletal, biomechanical, and physiological characteristics between male and female Soldiers requiring implementation of gender-specific training in order to mitigate injury risk and enhance performance. To examine differences in musculoskeletal, biomechanical, and physiological characteristics in male and female Soldiers. A total of 406 101st Airborne Division (Air Assault) Soldiers (348 male; 58 female) participated. Subjects underwent testing for flexibility, isokinetic and isometric strength (percent body weight), single-leg balance, lower body biomechanics during a stop jump and drop landing, body composition, anaerobic power/capacity, and aerobic capacity. Independent t tests assessed between-group comparisons. Women demonstrated significantly greater flexibility (P<.01-P<.001) and better balance (P≤.001) than men. Men demonstrated significantly greater strength (P≤.001), aerobic capacity (47.5±7.6 vs 40.3±5.4 ml/kg/min, P<.001), anaerobic power (13.3±2.1 vs 9.5±1.7 W/kg, P<.001), and anaerobic capacity (7.8±1.0 vs 6.1±0.8 W/kg, P<.001) and lower body fat (20.1±7.5 vs 26.7±5.7 (%BF), P<.001). Women demonstrated significantly greater hip flexion and knee valgus at initial contact during both the stop jump and drop landing tasks and greater knee flexion at initial contact during the drop landing task (P<.05-P<.001). Gender differences exist in biomechanical, musculoskeletal, and physiological characteristics. Sex-specific interventions may aid in improving such characteristics to optimize physical readiness and decrease the injury risk during gender-neutral training, and decreasing between-sex variability in performance characteristics may result in enhanced overall unit readiness. Identification of sex-specific differences in injury patterns and characteristics should facilitate adjustments in training in order for both sexes to meet the gender-neutral occupational demands for physically demanding military occupational specialties.
Performance in quasi-firms: an example from the Community Clinical Oncology Program.
Lacey, L M; Hynes, D M; Kaluzny, A D
1992-01-01
In this analysis, the authors examined the effects of different sets of process, structure, and environmental variables on the performance of the CCOP as a quasi-firm. Specifically, they distinguished between internal organizational processes, structural, and size characteristics of the CCOP and the organizational environment created by prior NCI program experience and the relationship within the quasi-firm. The analysis revealed that these sets of organizational and environmental characteristics have differential effects on treatment accrual. The strongest predictors are those associated with the quasi-firm relationship between the CCOP and its chosen research bases. Any definitive policy implications for the design of organizational network relationships--especially the CCOPs--will require further analysis. Particular attention needs to be given to the longitudinal nature of the relationships and the ability of these organizational and environmental factors to affect other aspects of performance. Several points have been made within this initial assessment. First, the structural character of the CCOP and its relationship to its organizational environment are important factors affecting accrual performance. The subtleties of this multivariate model are not as important as simply demonstrating that the various internal and external characteristics of these organizations as quasi-firms simultaneously affect their ability to accrue patients to clinical trials. Secondly, the importance of research base relations, and particularly the significant role of nurses, needs to be emphasized. While CCOPs were originally designed as a network of physicians and hospitals, it appears that an infrastructure of professionally active nurses working within a larger organizational environment is critical to success--at least as defined by accrual to treatment protocols. Finally, the failure of prior experience with other NCI community programs to affect CCOP accrual performance suggests that such experience does not assure "organizational learning" that may enhance performance. This suggests that CCOPs can be designated de novo to maximize performance without necessarily having to undergo a developmental or experiential phase involving community cancer programs to be effective. However, the authors suspect that another method of characterizing experience may produce different results. Further analyses of these data will test these results against other measures of CCOP performance. Specifically, attention will be given to whether this same set of characteristics is predictive of accrual to cancer control research protocols. Similarly, these same organizational characteristics may or may not be associated with other dimensions of CCOP performance such as changes in physician practice patterns and/or levels of institutionalization of the CCOP within its local community.(ABSTRACT TRUNCATED AT 400 WORDS)
Fuel cell power plant economic and operational considerations
NASA Technical Reports Server (NTRS)
Lance, J. R.
1984-01-01
Fuel cell power plants intended for electric utility and cogeneration applications are now in the design and construction stage. This paper describes economic and operational considerations being used in the development and design of plants utilizing air cooled phosphoric acid fuel cells. Fuel cell power plants have some unique characteristics relative to other types of power plants. As a result it was necessary to develop specific definitions of the fuel cell power plant characteristics in order to perform cost of electricity calculations. This paper describes these characteristics and describes the economic analyses used in the Westinghouse fuel cell power plant program.
Impact of minor actinide recycling on sustainable fuel cycle options
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heidet, F.; Kim, T. K.; Taiwo, T. A.
The recent Evaluation and Screening study chartered by the U.S. Department of Energy, Office of Nuclear Energy, has identified four fuel cycle options as being the most promising. Among these four options, the two single-stage fuel cycles rely on a fast reactor and are differing in the fact that in one case only uranium and plutonium are recycled while in the other case minor actinides are also recycled. The two other fuel cycles are two-stage and rely on both fast and thermal reactors. They also differ in the fact that in one case only uranium and plutonium are recycled whilemore » in the other case minor actinides are also recycled. The current study assesses the impact of recycling minor actinides on the reactor core design, its performance characteristics, and the characteristics of the recycled material and waste material. The recycling of minor actinides is found not to affect the reactor core performance, as long as the same cycle length, core layout and specific power are being used. One notable difference is that the required transuranics (TRU) content is slightly increased when minor actinides are recycled. The mass flows are mostly unchanged given a same specific power and cycle length. Although the material mass flows and reactor performance characteristics are hardly affected by recycling minor actinides, some differences are observed in the waste characteristics between the two fuel cycles considered. The absence of minor actinides in the waste results in a different buildup of decay products, and in somewhat different behaviors depending on the characteristic and time frame considered. Recycling of minor actinides is found to result in a reduction of the waste characteristics ranging from 10% to 90%. These results are consistent with previous studies in this domain and depending on the time frame considered, packaging conditions, repository site, repository strategy, the differences observed in the waste characteristics could be beneficial and help improve the repository performance. On the other hand, recycling minor actinides also results in an increase of the recycled fuel characteristics and therefore of the charged fuel. The radioactivity is slightly increased while the decay heat and radiotoxicities are very significantly increased. Despite these differences, the characteristics of the fuel at time of discharge remain similar whether minor actinides are recycled or not, with the exception of the inhalation radiotoxicity which is significantly larger with minor actinide recycling. After some cooling the characteristics of the discharged fuel become larger when minor actinides are recycled, potentially affecting the reprocessing plant requirements. Recycling minor actinides has a negative impact on the characteristics of the fresh fuel and will make it more challenging to fabricate fuel containing minor actinides.« less
What matters after sleeve gastrectomy: patient characteristics or surgical technique?
Dhar, Vikrom K; Hanseman, Dennis J; Watkins, Brad M; Paquette, Ian M; Shah, Shimul A; Thompson, Jonathan R
2018-03-01
The impact of operative technique on outcomes in laparoscopic sleeve gastrectomy has been explored previously; however, the relative importance of patient characteristics remains unknown. Our aim was to characterize national variability in operative technique for laparoscopic sleeve gastrectomy and determine whether patient-specific factors are more critical to predicting outcomes. We queried the database of the Metabolic and Bariatric Surgery Accreditation and Quality Improvement Program for laparoscopic sleeve gastrostomies performed in 2015 (n = 88,845). Logistic regression models were used to determine predictors of postoperative outcomes. In 2015, >460 variations of laparoscopic sleeve gastrectomy were performed based on combinations of bougie size, distance from the pylorus, use of staple line reinforcement, and oversewing of the staple line. Despite such substantial variability, technique variants were not predictive of outcomes, including perioperative morbidity, leak, or bleeding (all P ≥ .05). Instead, preoperative patient characteristics were found to be more predictive of these outcomes after laparoscopic sleeve gastrectomy. Only history of gastroesophageal disease (odds ratio 1.44, 95% confidence interval 1.08-1.91, P < .01) was associated with leak. Considerable variability exists in technique among surgeons nationally, but patient characteristics are more predictive of adverse outcomes after laparoscopic sleeve gastrectomy. Bundled payments and reimbursement policies should account for patient-specific factors in addition to current accreditation and volume thresholds when deciding risk-adjustment strategies. Copyright © 2018 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Vanyashov, A. D.; Karabanova, V. V.
2017-08-01
A mathematical description of the method for obtaining gas-dynamic characteristics of a centrifugal compressor stage is proposed, taking into account the control action by varying the rotor speed and the angle of rotation of the guide vanes relative to the "basic" characteristic, if the kinematic and dynamic similitude conditions are not met. The formulas of the correction terms for the non-dimensional coefficients of specific work, consumption and efficiency are obtained. A comparative analysis of the calculated gas-dynamic characteristics of a high-pressure centrifugal stage with experimental data is performed.
A model-based investigation of manipulator characteristics and pilot/vehicle performance
NASA Technical Reports Server (NTRS)
Hess, R. A.
1983-01-01
Hess (1978, 1981) has introduced and discussed a structural model of the human pilot in which proprioceptive feedback plays a fundamental role in determining pilot equalization characteristics. It is pointed out that, on account of the feedback structure, this model may provide more insight into the effects of certain manipulator characteristics upon pilot equalization than would other modeling approaches. The model is briefly discussed, and an outline is presented concerning some of the implications of the model structure regarding the manipulator characteristics. Attention is given to some specific empirical examples of manipulator effects involving glide slope tracking in STOL aircraft, taking into account an employment of the model as a theoretical framework.
NASA Astrophysics Data System (ADS)
Ganesan, A.; Alakhras, M.; Brennan, P. C.; Lee, W.; Tapia, K.; Mello-Thoms, C.
2018-03-01
Purpose: To determine the impact of Breast Screen Reader Assessment Strategy (BREAST) over time in improving radiologists' breast cancer detection performance, and to identify the group of radiologists that benefit the most by using BREAST as a training tool. Materials and Methods: Thirty-six radiologists who completed three case-sets offered by BREAST were included in this study. The case-sets were arranged in radiologists' chronological order of completion and five performance measures (sensitivity, specificity, location sensitivity, receiver operating characteristics area under the curve (ROC AUC) and jackknife alternative free-response receiver operating characteristic (JAFROC) figure-of-merit (FOM)), available from BREAST, were compared between case-sets to determine the level of improvement achieved. The radiologists were then grouped based on their characteristics and the above performance measures between the case-sets were compared. Paired t-tests or Wilcoxon signed-rank tests with statistical significance set at p < 0.05 were used to compare the performance measures. Results: Significant improvement was demonstrated in radiologists' case-set performance in terms of location sensitivity and JAFROC FOM over the years, and radiologists' location sensitivity and JAFROC FOM showed significant improvement irrespective of their characteristics. In terms of ROC AUC, significant improvement was shown for radiologists who were reading screen mammograms for more than 7 years and spent more than 9 hours per week reading mammograms. Conclusion: Engaging with case-sets appears to enhance radiologists' performance suggesting the important value of initiatives such as BREAST. However, such performance enhancement was not shown for everyone, highlighting the need to tailor the BREAST platform to benefit all radiologists.
Opstoel, Katrijn; Pion, Johan; Elferink-Gemser, Marije; Hartman, Esther; Willemse, Bas; Philippaerts, Renaat; Visscher, Chris; Lenoir, Matthieu
2015-01-01
The aim of this study was to investigate to what extent 9 to 11 year old children participating in a specific sport already exhibit a specific anthropometric, physical fitness and motor coordination profile, in line with the requirements of that particular sport. In addition, the profiles in children with a different training volume were compared and possible differences in training hours per week between children from a low, moderate, and high level of physical fitness and motor coordination were investigated. Data of 620 children, 347 boys and 273 girls, who participated in the Flemish Sports Compass were used. Only the primary sport of each child was considered and six groups of sports (Ball sports, Dance, Gymnastics, Martial arts, Racquet sports and Swimming) were formed based on common characteristics. Measurements consisted of 17 tests. Independent T-tests and Mann-Whitney U-tests revealed few differences between the groups of sports and the discriminant analyses with the moderate and low active group did not show any significant results (p > .05). However, when discriminating among the high active children, a 85.2 % correct classification between six groups of sports was found (Wilks' Λ = .137 and p < .001). Finally, children performing under average on the tests spent significantly fewer hours in sport per week (2.50 ± 1.84 hours) compared to the children performing best (3.25 ± 2.60 hours) (p = .016) and the children performing above average (2.90 ± 1.96 hours) (p = .029) on physical fitness and motor coordination. The study showed that in general, children at a young age do not exhibit sport-specific characteristics, except in children with a high training volume. It is possible that on the one hand, children have not spent enough time yet in their sport to develop sport-specific qualities. On the other hand, it could be possible that they do not take individual qualities into account when choosing a sport.
Testing some major determinants for hospital innovation success.
Caccia-Bava, Maria do Carmo; Guimaraes, Valerie C K; Guimaraes, Tor
2009-01-01
Hospitals have adopted new policies, methods and technologies to change their processes, improve services, and support other organizational changes necessary for better performance. The literature regarding the four major areas of strategic leadership, competitive intelligence, management of technology, and specific characteristics of the organization's change process propose their importance in successfully implementing organization innovation. While these factors may indeed be important to enhance hospital performance, the existing literature contains limited empirical evidence supporting their relationship to successfully implementing innovation in hospitals. This study aims to empirically test these relationships proposed in the literature by researchers in separate knowledge areas. A survey of 223 hospitals has been used to test an integrated model of these relationships. The response rate and the representativeness of the sample in terms of hospital size and geographical location were found satisfactory. The quality assurance/compliance managers for each hospital were the target respondents to questions, which require a corporate perspective while reducing the chance of bias for questions regarding top management leadership abilities. The results provide clear evidence about the importance of strategic leadership, competitive intelligence, management of technology, and specific characteristics of the hospital's change process to the hospitals success in implementing innovation. Given the importance of hospitals to change their processes, improve services, and support other organizational changes necessary for better performance, a great benefit is that the main factors for successful innovation have been brought together from scattered literature and tested among hospitals. Further, the items used for measuring the main constructs provide further insights into how hospital administrators should go about developing these areas within their organizations. This study is a first attempt at empirically testing the importance of strategic leadership, competitive intelligence, management of technology, and specific characteristics of the hospital's change process for the success of innovation efforts.
Timing of occurrence is the most important characteristic of spot sign
Xu, Mengjun; Zhang, Sheng; Liu, Keqin; Hu, Haitao; Selim, Magdy; Lou, Min
2016-01-01
Background and Purpose Most previous studies have used single-phase CT angiography (CTA) to detect the spot sign, a marker for hematoma expansion (HE) in spontaneous intracerebral hemorrhage (SICH). We investigated whether defining the spot sign based on timing on perfusion CT (CTP) would improve its specificity for predicting HE. Methods We prospectively enrolled supratentorial SICH patients, who underwent CTP within 6 h of onset. Logistic regression were performed to assess the risk factors for HE and poor outcome. Predictive performance of individual CTP spot sign characteristics were examined with receiver operating characteristic (ROC) analysis. Results Sixty-two men and 21 women with SICH were included in this analysis. Spot sign was detected in 46% (38/83) patients. ROC analysis indicated that the timing of spot sign occurrence on CTP had the greatest AUC for HE (0.794; 95% CI, 0.630-0.958; P=0.007); the cutoff time was 23.13 seconds. On multivariable analysis, the presence of early-occurring spot sign (EOSS; i.e. spot sign before 23.13 seconds) was an independent predictor, not only of HE (OR=28.835; 95% CI, 6.960-119.458; P<0.001), but also of mortality at 3 months (OR=22.377; 95% CI, 1.773-282.334; P=0.016). Moreover, the predictive performance showed that the redefined EOSS maintained a higher specificity for HE compared to spot sign (91% vs 74%). Conclusions Redefining the spot sign based on timing of contrast leakage on CTP to determine EOSS, improves the specificity for predicting HE and 3-month mortality. The use of EOSS could improve the selection of ICH patients for potential hemostatic therapy. PMID:27026627
Effect of broadened-specification fuels on aircraft engines and fuel systems
NASA Technical Reports Server (NTRS)
Rudey, R. A.
1979-01-01
A wide variety of studies on the potential effects of broadened-specification fuels on future aircraft engines and fuel systems are summarized. The compositions and characteristics of aircraft fuels that may be derived from current and future crude-oil sources are described, and the most critical properties that may effect aircraft engines and fuel systems are identified and discussed. The problems that are most likely to be encountered because of changes in selected fuel properties are explored; and the related effects on engine performance, component durability and maintenance, and aircraft fuel-system performance are examined. The ability of current technology to accept possible future fuel specification changes is assessed and selected technological advances that can reduce the severity of the potential problems are illustrated.
Effect of broadened-specification fuels on aircraft engines and fuel systems
NASA Technical Reports Server (NTRS)
Rudey, R. A.
1979-01-01
A wide variety of studies on the potential effects of broadened-specification fuels on future aircraft engines and fuel systems are summarized. The compositions and characteristics of aircraft fuels that may be derived from current and future crude-oil sources are described, and the most critical properties that may affect aircraft engines and fuel systems are identified and discussed. The problems that are most likely to be encountered because of changes in selected fuel properties are described; and the related effects on engine performance, component durability and maintenance, and aircraft fuel-system performance are discussed. The ability of current technology to accept possible future fuel-specification changes is discussed, and selected technological advances that can reduce the severity of the potential problems are illustrated.
An alternative respiratory sounds classification system utilizing artificial neural networks.
Oweis, Rami J; Abdulhay, Enas W; Khayal, Amer; Awad, Areen
2015-01-01
Computerized lung sound analysis involves recording lung sound via an electronic device, followed by computer analysis and classification based on specific signal characteristics as non-linearity and nonstationarity caused by air turbulence. An automatic analysis is necessary to avoid dependence on expert skills. This work revolves around exploiting autocorrelation in the feature extraction stage. All process stages were implemented in MATLAB. The classification process was performed comparatively using both artificial neural networks (ANNs) and adaptive neuro-fuzzy inference systems (ANFIS) toolboxes. The methods have been applied to 10 different respiratory sounds for classification. The ANN was superior to the ANFIS system and returned superior performance parameters. Its accuracy, specificity, and sensitivity were 98.6%, 100%, and 97.8%, respectively. The obtained parameters showed superiority to many recent approaches. The promising proposed method is an efficient fast tool for the intended purpose as manifested in the performance parameters, specifically, accuracy, specificity, and sensitivity. Furthermore, it may be added that utilizing the autocorrelation function in the feature extraction in such applications results in enhanced performance and avoids undesired computation complexities compared to other techniques.
Ashok Kumar, T; Chandramouli, R; Mohanraj, T
2015-11-01
Biodiesel is a clean renewable fuel derived from vegetable oils and animal fats. It is biodegradable, oxygenated, non toxic and free from sulfur and aromatics. The biodiesel prepared from pinnai oil undergoes acid esterification followed by alkaline transesterification process. The fatty acid methyl esters components were identified using gas chromatography and compared with the standard properties. The properties of biodiesel are comparable with diesel. The yield of the biodiesel production depends upon the process parameters such as reaction temperature, pH, time duration and amount of catalyst. The yield of biodiesel by transesterification process was 73% at 55°C. This fuel was tested in a variable compression ratio engine with blend ratios of B10 and B20. During the test runs the compression ratio of the engine was varied from 15:1 to 18:1 and the torque is adjusted from zero to maximum value of 22Nm. The performance characteristics such as the brake thermal efficiency, brake specific energy consumption and exhaust gas temperature of the engine are analyzed. The combustion characteristics of biodiesel like ignition delay, combustion duration and maximum gas temperature and the emission characteristics are also analyzed. The performance characteristics, combustion characteristics and engine emission are effective in the variable compression ratio engine with biodiesel and it is compared with diesel. Copyright © 2015 Elsevier Inc. All rights reserved.
Optimization and qualification of an Fc Array assay for assessments of antibodies against HIV-1/SIV.
Brown, Eric P; Weiner, Joshua A; Lin, Shu; Natarajan, Harini; Normandin, Erica; Barouch, Dan H; Alter, Galit; Sarzotti-Kelsoe, Marcella; Ackerman, Margaret E
2018-04-01
The Fc Array is a multiplexed assay that assesses the Fc domain characteristics of antigen-specific antibodies with the potential to evaluate up to 500 antigen specificities simultaneously. Antigen-specific antibodies are captured on antigen-conjugated beads and their functional capacity is probed via an array of Fc-binding proteins including antibody subclassing reagents, Fcγ receptors, complement proteins, and lectins. Here we present the results of the optimization and formal qualification of the Fc Array, performed in compliance with Good Clinical Laboratory Practice (GCLP) guidelines. Assay conditions were optimized for performance and reproducibility, and the final version of the assay was then evaluated for specificity, accuracy, precision, limits of detection and quantitation, linearity, range and robustness. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Characteristic and intermingled neocortical circuits encode different visual object discriminations.
Zhang, Guo-Rong; Zhao, Hua; Cook, Nathan; Svestka, Michael; Choi, Eui M; Jan, Mary; Cook, Robert G; Geller, Alfred I
2017-07-28
Synaptic plasticity and neural network theories hypothesize that the essential information for advanced cognitive tasks is encoded in specific circuits and neurons within distributed neocortical networks. However, these circuits are incompletely characterized, and we do not know if a specific discrimination is encoded in characteristic circuits among multiple animals. Here, we determined the spatial distribution of active neurons for a circuit that encodes some of the essential information for a cognitive task. We genetically activated protein kinase C pathways in several hundred spatially-grouped glutamatergic and GABAergic neurons in rat postrhinal cortex, a multimodal associative area that is part of a distributed circuit that encodes visual object discriminations. We previously established that this intervention enhances accuracy for specific discriminations. Moreover, the genetically-modified, local circuit in POR cortex encodes some of the essential information, and this local circuit is preferentially activated during performance, as shown by activity-dependent gene imaging. Here, we mapped the positions of the active neurons, which revealed that two image sets are encoded in characteristic and different circuits. While characteristic circuits are known to process sensory information, in sensory areas, this is the first demonstration that characteristic circuits encode specific discriminations, in a multimodal associative area. Further, the circuits encoding the two image sets are intermingled, and likely overlapping, enabling efficient encoding. Consistent with reconsolidation theories, intermingled and overlapping encoding could facilitate formation of associations between related discriminations, including visually similar discriminations or discriminations learned at the same time or place. Copyright © 2017 Elsevier B.V. All rights reserved.
Performance Testing of Yardney Li-Ion Cells and Batteries in Support of Future NASA Missions
NASA Technical Reports Server (NTRS)
Smart, M. C.; Ratnakumar, B. V.; Whitcanack, L. D.; Puglia, F. J.; Santee, S.; Gitzendanner, R.
2009-01-01
NASA requires lightweight rechargeable batteries for future missions to Mars and the outer planets that are capable of operating over a wide range of temperatures, with high specific energy and energy densities. Due to the attractive performance characteristics, Li-ion batteries have been identified as the battery chemistry of choice for a number of future applications. For example, JPL is planning to launch another unmanned rover mission to the planet Mars. This mission, referred to as the Mars Science Laboratory (MSL), will involve the use of a rover that is much larger than the previously developed Spirit and Opportunity Rovers for the 2003 Mars Exploration Rover (MER) mission, that are currently still in operation on the surface of the planet after more than five years. Part of the reason that the MER rovers have operated so successfully, far exceeding the required mission duration of 90 sols, is that they possess robust Li-ion batteries, manufactured by Yardney Technical Products, which have demonstrated excellent life characteristics. Given the excellent performance characteristics displayed, similar Li-ion batteries have been projected to successfully meet the mission requirements of the up-coming MSL mission. In addition to future missions to Mars, Li-ion technology is attractive for a number of other future NASA applications which require high specific energy, rechargeable batteries. To ascertain the viability of using Li-ion batteries for these applications, a number of performance validation tests have been performed on both Yardney cells and batteries of various sizes. These tests include mission simulation tests, charge and discharge rate characterization testing, cycle life testing under various conditions, and storage testing.
Study of LTPP laboratory resilient modulus test data and response characteristics.
DOT National Transportation Integrated Search
2002-10-01
The resilient modulus of every unbound structural layer of the Long Term Pavement Performance (LTPP) Specific Pavement and : General Pavement Studies Test Sections is being measured in the laboratory using LTPP test protocol P46. A total of 2,014 : r...
Performance of a low-power subsonic-arc-attachment arcjet thruster
NASA Technical Reports Server (NTRS)
Sankovic, John M.; Berns, Darren H.
1993-01-01
A subsonic-arc-attachment thruster design was scaled from a 30 kW 1960's vintage thruster to operate at nominally 3 kW. Performance measurements were obtained over a 1-4 kW power range using hydrogen as the propellant. Several modes of operation were identified and were characterized by varying degrees of voltage instability. A stability map was developed showing that the voltage oscillations were brought upon by elevated current or propellant levels. At a given specific energy level the specific impulse increased asymptotically with increased flow rates. Comparisons of performance were made between radial and tangential propellant injection. When the vortex flow was eliminated using radial injection, the operating voltages were lower at a given current, and the specific impulse and efficiency decreased. Tests were also conducted to determine the effects of background pressure on operation, and performance data were obtained at pressures of 0.047 Pa and 18 Pa. For a given specific energy level, the performance increased with a decrease in facility background pressure. Lowering the background pressure also caused a dramatic change in the voltage-current characteristic and the voltage stability, a phenomenon not previously reported with conventional supersonic-arc-attachment thrusters.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andon, J.; Dodson, E.; Khadilkar, A.
1975-06-01
Current passenger car usage patterns and factors influencing usage are analyzed and projections of usage patterns in the mid-1980's are made. Current available data on six categories of vehicle accidents are analyzed and projections made of national accident patterns in the mid-80's; the effect of potential reductions in these projections as a result of safety programs and other factors related to driving safety are estimated. Based on the usage and accident projections, the characteristics of an RSV (weighing under 3,000 lbs C.W.) for operation in the mid-1980 traffic environment are described. A recommended set of specifications for the RSV aremore » developed considering the potential safety payoff accruing to an increased level of safety performance, the need for energy conservation, availability of material resources, and changes in vehicle mix. (An executive summary of this report is presented in Volume I).« less
QTL mapping of sake brewing characteristics of yeast.
Katou, Taku; Namise, Masahiro; Kitagaki, Hiroshi; Akao, Takeshi; Shimoi, Hitoshi
2009-04-01
A haploid sake yeast strain derived from the commercial diploid sake yeast strain Kyokai no. 7 showed better characteristics for sake brewing compared to the haploid laboratory yeast strain X2180-1B, including higher production of ethanol and aromatic components. A hybrid of these two strains showed intermediate characteristics in most cases. After sporulation of the hybrid strain, we obtained 100 haploid segregants of the hybrid. Small-scale sake brewing tests of these segregants showed a smooth continuous distribution of the sake brewing characteristics, suggesting that these traits are determined by multiple quantitative trait loci (QTLs). To examine these sake brewing characteristics at the genomic level, we performed QTL analysis of sake brewing characteristics using 142 DNA markers that showed heterogeneity between the two parental strains. As a result, we identified 25 significant QTLs involved in the specification of sake brewing characteristics such as ethanol fermentation and the production of aromatic components.
Lee, Hye-Min; Kim, Hong-Gun; An, Kay-Hyeok; Kim, Byung-Joo
2015-11-01
The present study developed electrode materials for supercapacitors by activating coke-based activated carbons with CO2. For the activation reaction, after setting the temperature at 1,000 degrees C, four types of activated carbons were produced, over an activation time of 0-90 minutes and with an interval of 30 minutes as the unit. The electrochemical performance of the activated carbons produced was evaluated to examine the effect of CO2 activation. The surface structure of the porous carbons activated through CO2 activation was observed using a scanning electron microscope (SEM). To determine the N2/77 K isothermal adsorption characteristics, the Brunauer-Emmett-Teller (BET) equation and the Barrett-Joyner-Halenda (BJH) equation were used to analyze the pore characteristics. In addition, charge and discharge tests and cyclic voltammetry (CV) were used to analyze the electrochemical characteristics of the changed pore structure. According to the results of the experiments, the N2 adsorption isotherm curves of the porous carbons produced belonged to Type IV in the International Union of Pore and Applied Chemistry (IUPAC) classification and consisted of micropores and mesopores, and, as the activation of CO2 progressed, micropores decreased and mesopores developed. The specific surface area of the porous carbons activated by CO2 was 1,090-1,180 m2/g and thus showed little change, but those of mesopores were 0.43-0.85 cm3/g, thus increasing considerably. In addition, when the electrochemical characteristics were analyzed, the specific capacity was confirmed to have increased from 13.9 F/g to 18.3 F/g. From these results, the pore characteristics of coke-based activated carbons changed considerably because of CO2 activation, and it was therefore possible to increase the electrochemical characteristics.
NASA Astrophysics Data System (ADS)
Chen, Jun; Li, Guoxiu; Zhang, Tao; Wang, Meng; Yu, Yusong
2016-12-01
Low toxicity ammonium dinitramide (ADN)-based aerospace propulsion systems currently show promise with regard to applications such as controlling satellite attitude. In the present work, the decomposition and combustion processes of an ADN-based monopropellant thruster were systematically studied, using a thermally stable catalyst to promote the decomposition reaction. The performance of the ADN propulsion system was investigated using a ground test system under vacuum, and the physical properties of the ADN-based propellant were also examined. Using this system, the effects of the preheating temperature and feed pressure on the combustion characteristics and thruster performance during steady state operation were observed. The results indicate that the propellant and catalyst employed during this work, as well as the design and manufacture of the thruster, met performance requirements. Moreover, the 1 N ADN thruster generated a specific impulse of 223 s, demonstrating the efficacy of the new catalyst. The thruster operational parameters (specifically, the preheating temperature and feed pressure) were found to have a significant effect on the decomposition and combustion processes within the thruster, and the performance of the thruster was demonstrated to improve at higher feed pressures and elevated preheating temperatures. A lower temperature of 140 °C was determined to activate the catalytic decomposition and combustion processes more effectively compared with the results obtained using other conditions. The data obtained in this study should be beneficial to future systematic and in-depth investigations of the combustion mechanism and characteristics within an ADN thruster.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ju, Xiaohui; Bowden, Mark E.; Engelhard, Mark H.
Three commercial cellulase preparations, Novozymes Cellic® Ctec2, Dupont Accellerase® 1500, and DSM Cytolase CL, were evaluated for their hydrolytic activity using a set of reference biomass substrates with controlled substrate characteristics. It was found that lignin remains a significant recalcitrance factor to all the preparations, although different enzyme preparations respond to the inhibitory effect of lignin differently. Also, different types of biomass lignin can inhibit cellulose enzymes in different manners. Enhancing enzyme activity toward biomass fiber swelling is an area significantly contributing to potential improvement in cellulose performance. While the degree of polymerization of cellulose in the reference substrates didmore » not present a major recalcitrance factor to Novozymes Cellic® Ctec2, cellulose crystallite has been shown to have a significant lower reactivity toward all enzyme mixtures. The presence of polysaccharide monooxygenases (PMOs) in Novozymes Ctec2 appears to enhance enzyme activity toward decrystallization of cellulose. This study demonstrated that reference substrates with controlled chemical and physical characteristics of structural features can be applied as an effective and practical strategy to identify cellulosic enzyme activities toward specific biomass recalcitrance factor(s) and provide specific targets for enzyme improvement.« less
Ju, Xiaohui; Bowden, Mark; Engelhard, Mark; Zhang, Xiao
2014-05-01
Three commercial cellulase preparations, Novozymes Cellic(®) Ctec2, Dupont Accellerase(®) 1500, and DSM Cytolase CL, were evaluated for their hydrolytic activity using a set of reference biomass substrates with controlled substrate characteristics. It was found that lignin remains a significant recalcitrance factor to all the preparations, although different enzyme preparations respond to the inhibitory effect of lignin differently. Also, different types of biomass lignin can inhibit cellulase enzymes in different manners. Enhancing enzyme activity toward biomass fiber swelling is an area significantly contributing to potential improvement in cellulase performance. While the degree of polymerization of cellulose in the reference substrates did not present a major recalcitrance factor to Novozymes Cellic(®) Ctec2, cellulose crystallite has been shown to have a significant lower reactivity toward all enzyme mixtures. The presence of polysaccharide monooxygenases (PMOs) in Novozymes Ctec2 appears to enhance enzyme activity toward decrystallization of cellulose. This study demonstrated that reference substrates with controlled chemical and physical characteristics of structural features can be applied as an effective and practical strategy to identify cellulosic enzyme activities toward specific biomass recalcitrance factor(s) and provide specific targets for enzyme improvement.
Performance, emissions, and physical characteristics of a rotating combustion aircraft engine
NASA Technical Reports Server (NTRS)
Berkowitz, M.; Hermes, W. L.; Mount, R. E.; Myers, D.
1976-01-01
The RC2-75, a liquid cooled two chamber rotary combustion engine (Wankel type), designed for aircraft use, was tested and representative baseline (212 KW, 285 BHP) performance and emissions characteristics established. The testing included running fuel/air mixture control curves and varied ignition timing to permit selection of desirable and practical settings for running wide open throttle curves, propeller load curves, variable manifold pressure curves covering cruise conditions, and EPA cycle operating points. Performance and emissions data were recorded for all of the points run. In addition to the test data, information required to characterize the engine and evaluate its performance in aircraft use is provided over a range from one half to twice its present power. The exhaust emissions results are compared to the 1980 EPA requirements. Standard day take-off brake specific fuel consumption is 356 g/KW-HR (.585 lb/BHP-HR) for the configuration tested.
Hogan, Tiffany P.
2010-01-01
In this study, we examined the influence of word-level phonological and lexical characteristics on early phoneme awareness. Typically-developing children, ages 61–78 months, completed a phoneme-based, odd-one-out task that included consonant-vowel-consonant word sets (e.g., “chair-chain-ship”) that varied orthogonally by a phonological characteristic, sound-contrast similarity (similar vs. dissimilar), and a lexical characteristic, neighborhood density (dense vs. sparse). In a subsample of the participants – those with the highest vocabularies – results were in line with a predicted interactive effect of phonological and lexical characteristics on phoneme awareness performance: word sets contrasting similar sounds were less likely to yield correct responses in words from sparse neighborhoods than words from dense neighborhoods. Word sets contrasting dissimilar sounds were most likely to yield correct responses regardless of the words’ neighborhood density. Based on these findings, theories of early phoneme awareness development should consider both word-level (e.g., phonological and lexical characteristics) and child-level (e.g., vocabulary knowledge) influences on phoneme awareness performance. Attention to these word-level item influences is predicted to result in more sensitive and specific measures of reading risk. PMID:20574064
Understanding the effect of hammering process on the vibration characteristics of cymbals
NASA Astrophysics Data System (ADS)
Kuratani, F.; Yoshida, T.; Koide, T.; Mizuta, T.; Osamura, K.
2016-09-01
Cymbals are thin domed plates used as percussion instruments. When cymbals are struck, they vibrate and radiate sound. Cymbals are made through spin forming, hammering, and lathing. The spin forming creates the basic shape of the cymbal, which determines its basic vibration characteristics. The hammering and lathing produce specific sound adjustments by changing the cymbal's vibration characteristics. In this study, we study how hammering cymbals affects their vibration characteristics. The hammering produces plastic deformation (small, shallow dents) on the cymbal's surface, generating residual stresses throughout it. These residual stresses change the vibration characteristics. We perform finite element analysis of a cymbal to obtain its stress distribution and the resulting change in vibration characteristics. To reproduce the stress distribution, we use thermal stress analysis, and then with this stress distribution we perform vibration analysis. These results show that each of the cymbal's modes has a different sensitivity to the thermal load (i.e., hammering). This difference causes changes in the frequency response and the deflection shape that significantly improves the sound radiation efficiency. In addition, we explain the changes in natural frequencies by the stress and modal strain energy distributions.
Dietrich, Julia Felicitas; Nuerk, Hans-Christoph; Klein, Elise; Moeller, Korbinian; Huber, Stefan
2017-08-29
Previous research has proposed that the approximate number system (ANS) constitutes a building block for later mathematical abilities. Therefore, numerous studies investigated the relationship between ANS acuity and mathematical performance, but results are inconsistent. Properties of the experimental design have been discussed as a potential explanation of these inconsistencies. In the present study, we investigated the influence of set size and presentation duration on the association between non-symbolic magnitude comparison and math performance. Moreover, we focused on strategies reported as an explanation for these inconsistencies. In particular, we employed a non-symbolic magnitude comparison task and asked participants how they solved the task. We observed that set size was a significant moderator of the relationship between non-symbolic magnitude comparison and math performance, whereas presentation duration of the stimuli did not moderate this relationship. This supports the notion that specific design characteristics contribute to the inconsistent results. Moreover, participants reported different strategies including numerosity-based, visual, counting, calculation-based, and subitizing strategies. Frequencies of these strategies differed between different set sizes and presentation durations. However, we found no specific strategy, which alone predicted arithmetic performance, but when considering the frequency of all reported strategies, arithmetic performance could be predicted. Visual strategies made the largest contribution to this prediction. To conclude, the present findings suggest that different design characteristics contribute to the inconsistent findings regarding the relationship between non-symbolic magnitude comparison and mathematical performance by inducing different strategies and additional processes.
Feedback and the rationing of time and effort among competing tasks.
Northcraft, Gregory B; Schmidt, Aaron M; Ashford, Susan J
2011-09-01
The study described here tested a model of how characteristics of the feedback environment influence the allocation of resources (time and effort) among competing tasks. Results demonstrated that performers invest more resources on tasks for which higher quality (more timely and more specific) feedback is available; this effect was partially mediated by task salience and task expectancies. Feedback timing and feedback specificity demonstrated both main and interaction effects on resource allocations. Results also demonstrated that performers do better on tasks for which higher quality feedback is available; this effect was mediated by resources allocated to tasks. The practical and theoretical implications of the role of the feedback environment in managing performance are discussed. PsycINFO Database Record (c) 2011 APA, all rights reserved
NASA Astrophysics Data System (ADS)
Jasni, M. R. M.; Deraman, M.; Suleman, M.; Hamdan, E.; Sazali, N. E. S.; Nor, N. S. M.; Shamsudin, S. A.
2016-02-01
Graphene with its typical nano-scale characteristic properties has been widely used as an additive in activated carbon electrodes in order to enhance the performance of the electrodes for their use in high performance supercapacitors. Activated carbon monoliths (ACMs) electrodes have been prepared by carbonization and activation of green monoliths (GMs) of pre-carbonized fibers of oil palm empty fruit bunches or self-adhesive carbon grains (SACGs) and SACGs added with 6 wt% of KOH-treated multi-layer graphene. ACMs electrodes have been assembled in symmetrical supercapacitor cells that employed aqueous KOH electrolyte (6 M). The cells have been tested with cyclic voltammetry, electrochemical impedance spectroscopy and galvanostatic charge discharge methods to investigate the effect of graphene addition on the specific capacitance (Csp), specific energy (E), specific power (P), equivalent series resistance (ESR) and response time (τo) of the supercapacitor cells. The results show that the addition of graphene in the GMs change the values of Csp, Emax, Pmax, ESR and τo from (61-96) F/g, 2 Wh/kg, 104 W/kg, 2.6 Ω and 38 s, to the respective values of (110-124) F/g, 3 Wh/kg, 156 W/kg, 3.4 Ω and 63 s. This study demonstrates that the graphene addition in the GMs has a significant effect on the electrochemical behavior of the electrodes.
Mitchell, J M; Yee, A J; McNab, W B; Griffiths, M W; McEwen, S A
1999-01-01
LacTek tests are competitive enzyme-linked immunosorbent assays intended for rapid detection of antimicrobial residues in bovine milk. In this study, the LacTek test protocol was modified for use with extracts of bovine tissue to detect beta-lactam, tetracycline, and sulfamethazine residues. Test performance characteristics--precision, accuracy, ruggedness, practicability, and analytical specificity and sensitivity--were investigated. Results suggest that LacTek tests can be easily adapted to detect antimicrobial residues in extracts of lean ground beef. However, positive samples may not contain residues at violative concentrations (i.e., Canadian maximum residue limits), and therefore, additional analysis would be required for final confirmation and quantitation (e.g., chromatography).
The development and test of ultra-large-format multi-anode microchannel array detector systems
NASA Technical Reports Server (NTRS)
Timothy, J. G.
1984-01-01
The specific tasks that were accomplished with each of the key elements of the multi-anode microchannel array detector system are described. The modes of operation of position-sensitive electronic readout systems for use with high-gain microchannel plates are described and their performance characteristics compared and contrasted. Multi-anode microchannel array detector systems with formats as large as 256 x 1024 pixels are currently under evaluation. Preliminary performance data for sealed ultraviolet and visible-light detector tubes show that the detector systems have unique characteristics which make them complementary to photoconductive array detectors, such as CCDs, and superior to alternative pulse-counting detector systems employing high-gain MCPs.
Tests of two new polyurethane foam wheelchair tires.
Gordon, J; Kauzlarich, J J; Thacker, J G
1989-01-01
The performance characteristics of four 24-inch wheelchair tires are considered; one pneumatic and three airless. Specifically, two new airless polyurethane foam tires (circular and tapered cross-section) were compared to both a molded polyisoprene tire and a rubber pneumatic tire. Rolling resistance, coefficient of static friction, spring rate, tire roll-off, impact absorption, wear resistance, and resistance to compression set were the characteristics considered for the basis of comparison. Although the pneumatic tire is preferred by many wheelchair users, the two new polyurethane foam tires were found to offer a performance similar to the high-pressure pneumatic tire. In addition, the foam tires are less expensive and lighter in weight than the other tires tested.
Characteristic Model of a Shock Absorber in an Unmanned Ground Vehicle
NASA Astrophysics Data System (ADS)
Danko, Ján; Milesich, Tomáš; Bugár, Martin; Madarás, Juraj
2012-12-01
Li, Xiaohong; Brock, Guy N; Rouchka, Eric C; Cooper, Nigel G F; Wu, Dongfeng; O'Toole, Timothy E; Gill, Ryan S; Eteleeb, Abdallah M; O'Brien, Liz; Rai, Shesh N
2017-01-01
Normalization is an essential step with considerable impact on high-throughput RNA sequencing (RNA-seq) data analysis. Although there are numerous methods for read count normalization, it remains a challenge to choose an optimal method due to multiple factors contributing to read count variability that affects the overall sensitivity and specificity. In order to properly determine the most appropriate normalization methods, it is critical to compare the performance and shortcomings of a representative set of normalization routines based on different dataset characteristics. Therefore, we set out to evaluate the performance of the commonly used methods (DESeq, TMM-edgeR, FPKM-CuffDiff, TC, Med UQ and FQ) and two new methods we propose: Med-pgQ2 and UQ-pgQ2 (per-gene normalization after per-sample median or upper-quartile global scaling). Our per-gene normalization approach allows for comparisons between conditions based on similar count levels. Using the benchmark Microarray Quality Control Project (MAQC) and simulated datasets, we performed differential gene expression analysis to evaluate these methods. When evaluating MAQC2 with two replicates, we observed that Med-pgQ2 and UQ-pgQ2 achieved a slightly higher area under the Receiver Operating Characteristic Curve (AUC), a specificity rate > 85%, the detection power > 92% and an actual false discovery rate (FDR) under 0.06 given the nominal FDR (≤0.05). Although the top commonly used methods (DESeq and TMM-edgeR) yield a higher power (>93%) for MAQC2 data, they trade off with a reduced specificity (<70%) and a slightly higher actual FDR than our proposed methods. In addition, the results from an analysis based on the qualitative characteristics of sample distribution for MAQC2 and human breast cancer datasets show that only our gene-wise normalization methods corrected data skewed towards lower read counts. However, when we evaluated MAQC3 with less variation in five replicates, all methods performed similarly. Thus, our proposed Med-pgQ2 and UQ-pgQ2 methods perform slightly better for differential gene analysis of RNA-seq data skewed towards lowly expressed read counts with high variation by improving specificity while maintaining a good detection power with a control of the nominal FDR level.
Li, Xiaohong; Brock, Guy N.; Rouchka, Eric C.; Cooper, Nigel G. F.; Wu, Dongfeng; O’Toole, Timothy E.; Gill, Ryan S.; Eteleeb, Abdallah M.; O’Brien, Liz
2017-01-01
Normalization is an essential step with considerable impact on high-throughput RNA sequencing (RNA-seq) data analysis. Although there are numerous methods for read count normalization, it remains a challenge to choose an optimal method due to multiple factors contributing to read count variability that affects the overall sensitivity and specificity. In order to properly determine the most appropriate normalization methods, it is critical to compare the performance and shortcomings of a representative set of normalization routines based on different dataset characteristics. Therefore, we set out to evaluate the performance of the commonly used methods (DESeq, TMM-edgeR, FPKM-CuffDiff, TC, Med UQ and FQ) and two new methods we propose: Med-pgQ2 and UQ-pgQ2 (per-gene normalization after per-sample median or upper-quartile global scaling). Our per-gene normalization approach allows for comparisons between conditions based on similar count levels. Using the benchmark Microarray Quality Control Project (MAQC) and simulated datasets, we performed differential gene expression analysis to evaluate these methods. When evaluating MAQC2 with two replicates, we observed that Med-pgQ2 and UQ-pgQ2 achieved a slightly higher area under the Receiver Operating Characteristic Curve (AUC), a specificity rate > 85%, the detection power > 92% and an actual false discovery rate (FDR) under 0.06 given the nominal FDR (≤0.05). Although the top commonly used methods (DESeq and TMM-edgeR) yield a higher power (>93%) for MAQC2 data, they trade off with a reduced specificity (<70%) and a slightly higher actual FDR than our proposed methods. In addition, the results from an analysis based on the qualitative characteristics of sample distribution for MAQC2 and human breast cancer datasets show that only our gene-wise normalization methods corrected data skewed towards lower read counts. However, when we evaluated MAQC3 with less variation in five replicates, all methods performed similarly. Thus, our proposed Med-pgQ2 and UQ-pgQ2 methods perform slightly better for differential gene analysis of RNA-seq data skewed towards lowly expressed read counts with high variation by improving specificity while maintaining a good detection power with a control of the nominal FDR level. PMID:28459823
Matthew Fields, J; Davis, Joshua; Alsup, Carl; Bates, Amanda; Au, Arthur; Adhikari, Srikar; Farrell, Isaac
2017-09-01
The use of ultrasonography (US) to diagnose appendicitis is well established. More recently, point-of-care ultrasonography (POCUS) has also been studied for the diagnosis of appendicitis, which may also prove a valuable diagnostic tool. The purpose of this study was through systematic review and meta-analysis to identify the test characteristics of POCUS, specifically US performed by a nonradiologist physician, in accurately diagnosing acute appendicitis in patients of any age. We conducted a thorough and systematic literature search of English language articles published on point-of-care, physician-performed transabdominal US used for the diagnosis of acute appendicitis from 1980 to May, 2015 using OVID MEDLINE In-Process & Other Non-indexed Citations and Scopus. Studies were selected and subsequently independently abstracted by two trained reviewers. A random-effects pooled analysis was used to construct a hierarchical summary receiver operator characteristic curve, and a meta-regression was performed. Quality of studies was assessed using the QUADAS-2 tool. Our search yielded 5,792 unique studies and we included 21 of these in our final review. Prevalence of disease in this study was 29.8%, (range = 6.4%-75.4%). The sensitivity and specificity for POCUS in diagnosing appendicitis were 91% (95% confidence interval [CI] = 83%-96%) and 97% (95% CI = 91%-99%), respectively. The positive and negative predictive values were 91 and 94%, respectively. Studies performed by emergency physicians had slightly lower test characteristics (sensitivity = 80%, specificity = 92%). There was significant heterogeneity between studies (I 2 = 99%, 95% CI = 99%-100%) and the quality of the reported studies was moderate, mostly due to unclear reporting of blinding of physicians and timing of scanning and patient enrollment. Several of the studies were performed by a single operator, and the education and training of the operators were variably reported. Point-of-care US has relatively high sensitivity and specificity for diagnosing acute appendicitis, although the data presented are limited by the quality of the original studies and large CIs. In the hands of an experienced operator, POCUS is an appropriate initial imaging modality for diagnosing appendicitis. Based on our results, it is premature to utilize POCUS as a stand-alone test or to rule out appendicitis. © 2017 by the Society for Academic Emergency Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1963-04-01
Data obtained during the performance testing of the PM-1 plant were compiled and evaluated. The plant powers an Air Defense Command radar station located at Sundance, Wyoming, and is required to supply extremely high-quality electrical power (minimum of frequency and voltage fluctuations) even during severe load transients. The data obtained were compiled into the following format: (1) operating requirements; (2) startup requirements; (3) plant as an energy source; (4) plant radiation levels and health physics; (5) plant instrumentation and control; (6) reactor characteristics; (7) primary system characteristics; (8) secondary system characteristics; and (9) malfunction reports. It was concluded from themore » data that the plant performance in general meets or exceeds specification. Transient and steady-state electrical fluctuations are well within specified limitations. Heat balance data for both the primary and secondary system agree reasonably well with design predictions. Radiation levels are below those anticipated. Coolant activity in the primary system is approximately at anticipated levels; secondary system coolant activity is negligible. The core life was re-estimated based on asbuilt core characteristics. A lifetime of 16.6 Mw-yr is predicted. (auth)« less
NASA Technical Reports Server (NTRS)
Hirshberg, A. S.
1975-01-01
The following topics are discussed: (1) Assignment of population to microclimatic zones; (2) specifications of the mix of buildings in the SCE territory; (3) specification of four typical buildings for thermal analysis and market penetration studies; (4) identification of the materials and energy conserving characteristics of these typical buildings; (5) specifications of the HVAC functions used in each typical building, and determination of the HVAC systems used in each building; and (6) identification of the type of fuel used in each building.
Petersen, Per H; Lund, Flemming; Fraser, Callum G; Sölétormos, György
2016-11-01
Background The distributions of within-subject biological variation are usually described as coefficients of variation, as are analytical performance specifications for bias, imprecision and other characteristics. Estimation of specifications required for reference change values is traditionally done using relationship between the batch-related changes during routine performance, described as Δbias, and the coefficients of variation for analytical imprecision (CV A ): the original theory is based on standard deviations or coefficients of variation calculated as if distributions were Gaussian. Methods The distribution of between-subject biological variation can generally be described as log-Gaussian. Moreover, recent analyses of within-subject biological variation suggest that many measurands have log-Gaussian distributions. In consequence, we generated a model for the estimation of analytical performance specifications for reference change value, with combination of Δbias and CV A based on log-Gaussian distributions of CV I as natural logarithms. The model was tested using plasma prolactin and glucose as examples. Results Analytical performance specifications for reference change value generated using the new model based on log-Gaussian distributions were practically identical with the traditional model based on Gaussian distributions. Conclusion The traditional and simple to apply model used to generate analytical performance specifications for reference change value, based on the use of coefficients of variation and assuming Gaussian distributions for both CV I and CV A , is generally useful.
Investigation on VOX/CNTS Nanocomposites Act as Electrode of Supercapacitors
NASA Astrophysics Data System (ADS)
Zhu, Quanyao; Li, Zhaolong; Zhang, Xiaoyan; Huang, Shengnan; Yu, Yue; Chen, Wen; Zakharova, Galina S.
2013-07-01
The VOx/CNTs nanocomposites were synthesized by the hydrothermal method. The structure and morphologies of the nanocomposites were characteristic by XRD, SEM and TEM. The electrochemical properties of the nanocomposites were explored by cyclic voltammetry, constant current charge/discharge testing and electrochemical impedance spectroscopy in 1M KNO3 aqueous solution. The results showed that the nanocomposites perform characteristics of electrical both double-layer capacitance and pseudocapacitance. The specific capacitances were 136.5F/g, when the current density was 0.15A/g.
Alcaraz-Ibañez, Manuel; Rodríguez-Pérez, Manuel
2018-03-01
The aim of this work was to identify, synthesize and evaluate the results of randomized controlled trials examining the effects of resistance training on performance indicators in previously trained endurance runners. A database search was carried out in PubMed, Science Direct, OvidSPMedLine, Wiley, Web of Science, ProQuest and Google Scholar. In accordance with the PRISMA checklist, 18 published articles dated prior to May 2016 involving 321 endurance runners were reviewed using the PEDro scale. Resistance training led to general improvements in muscular strength, running economy, muscle power factors, and direct performance in distances between 1,500 and 10,000 m. Such improvements were not accompanied by a significant increase in body mass or signs of overtraining. However, improvements did not occur in all cases, suggesting that they might depend on the specific characteristics of the resistance training applied. Although current evidence supports the effectiveness of resistance training to improve performance in already trained endurance runners, the methodological inconsistencies identified suggest that the results should be interpreted with caution. Future studies ought to investigate the benefits of resistance training in endurance runners while considering the existence of possible differentiated effects based on the specific characteristics of the resistance training carried out.
Kut'in, S D; Konstantinov, V M
2008-01-01
Studies on specific features of nesting bird populations in patchy landscapes were performed in Meshchovsk Opolye, Kaluga Region, from 1981 to 1990. Indices of similarity between the avifaunas of agricultural fields, lowland bogs, and small-leaved forests markedly differed from parameters of their population density in rank and value. In the series of biotopes differing in the relative amount of woodland, from central areas of small-leaved forests to forest margins and then to forest islands gradually decreasing in size, the birds segregated into two distinct groups, one characteristic of forest margins and large forest islands and the other characteristic of small and very small forest islands. Specific features of bird density distribution in forest-meadow-field landscapes of Meshchovsk Opolye reflected heterogeneity of their populations manifested in diverse connections with nesting biotopes.
NASA Astrophysics Data System (ADS)
Trindade, I. G.; Leitão, D.; Fermento, R.; Pogorelev, Y.; Sousa, J. B.
2009-08-01
In-situ electrical resistance measurements were performed to obtain the scattering characteristics of very thin polycrystalline metal transition magnetic alloys grown by ion beam deposition (IBD) on specific underlayers. The experimental curves show size effects at small film thicknesses and important differences between Co 85Fe 15 and Ni 81Fe 19 thin layers grown on identical underlayers of Ta70 Å/Ru13 Å. The largest difference was observed in Ni 81Fe 19 films grown on underlayers of amorphous Ta70 Å. The experimental curves of electrical resistivity/conductivity variation with layer thickness were well fit within the Mayadas and Shatzkes (M-S) model, assuming specific formulations for grain growth with layer thickness.
Theoretical Performance of Hydrogen-Oxygen Rocket Thrust Chambers
NASA Technical Reports Server (NTRS)
Sievers, Gilbert K.; Tomazic, William A.; Kinney, George R.
1961-01-01
Data are presented for liquid-hydrogen-liquid-oxygen thrust chambers at chamber pressures from 15 to 1200 pounds per square inch absolute, area ratios to approximately 300, and percent fuel from about 8 to 34 for both equilibrium and frozen composition during expansion. Specific impulse in vacuum, specific impulse, combustion-chamber temperature, nozzle-exit temperature, characteristic velocity, and the ratio of chamber-to-nozzle-exit pressure are included. The data are presented in convenient graphical forms to allow quick calculation of theoretical nozzle performance with over- or underexpansion, flow separation, and introduction of the propellants at various initial conditions or heat loss from the combustion chamber.
NASA Technical Reports Server (NTRS)
Rudolph, L. K.; Jahn, R. G.; Clark, K. E.; Von Jaskowsky, W. F.
1976-01-01
The onset of voltage fluctuations in a multi-megawatt quasi-steady MPD accelerator, indicative of increased cathode ablation and a consequent degradation of performance, is found to be a function of cathode size. With longer cathodes, this onset shifts to substantially higher powers per unit mass flow and the plasma exhaust velocity can be increased to values previously thought inaccessible to accelerators of this class. Centerline velocities up to 30 km/sec have been measured in argon, which for the observed exhaust profiles translate into specific impulses up to 2400 sec and corresponding thrust efficiencies above 30%.
Is site-specific APEX calibration necessary for field scale BMP assessment?
USDA-ARS?s Scientific Manuscript database
The possibility of extending parameter sets obtained at one site to sites with similar characteristics is appealing. This study was undertaken to test model performance and compare the effectiveness of best management practices (BMPs) using three parameters sets obtained from three watersheds when a...
DOT National Transportation Integrated Search
1984-01-01
Results of usual tests for specification compliance and special tests to show viscosity-temperature susceptibility and ductility penetration relationships for asphalts supplied for use by the Virginia Department of Highways and Transportation in 1983...
Scintillator performance considerations for dedicated breast computed tomography
NASA Astrophysics Data System (ADS)
Vedantham, Srinivasan; Shi, Linxi; Karellas, Andrew
2017-09-01
Dedicated breast computed tomography (BCT) is an emerging clinical modality that can eliminate tissue superposition and has the potential for improved sensitivity and specificity for breast cancer detection and diagnosis. It is performed without physical compression of the breast. Most of the dedicated BCT systems use large-area detectors operating in cone-beam geometry and are referred to as cone-beam breast CT (CBBCT) systems. The large-area detectors in CBBCT systems are energy-integrating, indirect-type detectors employing a scintillator that converts x-ray photons to light, followed by detection of optical photons. A key consideration that determines the image quality achieved by such CBBCT systems is the choice of scintillator and its performance characteristics. In this work, a framework for analyzing the impact of the scintillator on CBBCT performance and its use for task-specific optimization of CBBCT imaging performance is described.
Fitness testing of tennis players: How valuable is it?
Fernandez-Fernandez, Jaime; Ulbricht, Alexander; Ferrauti, Alexander
2014-01-01
In tennis, sport-specific technical skills are predominant factors, although a complex profile of physical performance factors is also required. The fitness test batteries assist in examining tennis players’ capabilities for performance at different levels in the laboratory as well as in the field, in the junior or elite level. While laboratory tests can be, and are, used to evaluate basic performance characteristics of athletes in most individual sports, in a more specific approach, field-based methods are better suited to the demands of complex intermittent sports like tennis. A regular test battery performed at different periods of the year allows to obtain an individual's performance profile, as well as the ability to prescribe individual training interventions. Thus, the aim of the present review was to describe and evaluate the different physical tests recommended and used by practitioners, sports scientists and institutions (national tennis federations). PMID:24668375
Sattler, Sebastian; Forlini, Cynthia; Racine, Eric; Sauer, Carsten
2013-01-01
Enhancing cognitive performance with substances--especially prescription drugs--is a fiercely debated topic among scholars and in the media. The empirical basis for these discussions is limited, given that the actual nature of factors that influence the acceptability of and willingness to use cognitive enhancement substances remains unclear. In an online factorial survey, contextual and substance-specific characteristics of substances that improve academic performance were varied experimentally and presented to respondents. Students in four German universities rated their willingness to use and moral acceptance of different substances for cognitive enhancement. We found that the overall willingness to use performance enhancing substances is low. Most respondents considered the use of these substances as morally unacceptable. Situational influences such as peer pressure, policies concerning substance use, relative performance level of peers, but also characteristics of the substance, such as perceptions of substance safety, shape the willingness and acceptability of using a substance to enhance academic performance. Among the findings is evidence of a contagion effect meaning that the willingness was higher when the respondents have more CE drug users in their social network. We also found deterrence effects from strong side effects of using the substance, as well as from policy regulations and sanctions. Regulations might activate social norms against usage and sanctions can be seen as costly to users. Moreover, enhancement substances seem to be most tempting to low performers to catch up with others compared to high performers. By identifying contextual factors and substance characteristics influencing the willingness and acceptability of cognitive enhancers, policy approaches could consider these insights to better manage the use of such substances.
Performance Characteristics of a DME Propellant Arcjet Thruster
NASA Astrophysics Data System (ADS)
Kakami, Akira; Beeppu, Shinji; Maiguma, Muneyuki; Tachibana, Takeshi
This paper describes the influence of cathode configuration on performance of an arcjet thruster using dimethyl ether (DME) propellant. DME, an ether compound, has suitable characteristics for a space propulsion system; DME is storable in a liquid state without being kept under a high pressure, and requires no sophisticated temperature management such as a cryogenic device. DME can be gasified and liquefied simply by adjusting temperature whereas hydrazine, a conventional propellant, requires an iridium-based particulate catalyst for its gasification. In this study, thrust of a 1-kW class DME arcjet thruster is measured at a discharge current of 13 A, DME mass flow rates ranging 15 to 60 mg/s under three cathode configurations: flat-tip rods of 2 and 4 mm in diam. and 4-mm-diam. rod having a cavity of 2 mm in diameter. Thrust measurements show that thrust is increased with propellant mass flow rate. Among the tested cathodes, the flat-tip rod of 4 mm in diam. with 55 mg/s DME flow rate yielded the highest performance: specific impulse of 330 s, thrust of 0.18 N, discharge power of 1400 W and specific power of 25 MJ/kg.
Deficient symbol processing in Alzheimer disease.
Toepper, Max; Steuwe, Carolin; Beblo, Thomas; Bauer, Eva; Boedeker, Sebastian; Thomas, Christine; Markowitsch, Hans J; Driessen, Martin; Sammer, Gebhard
2014-01-01
Symbols and signs have been suggested to improve the orientation of patients suffering from Alzheimer disease (AD). However, there are hardly any studies that confirm whether AD patients benefit from signs or symbols and which symbol characteristics might improve or impede their symbol comprehension. To address these issues, 30 AD patients and 30 matched healthy controls performed a symbol processing task (SPT) with 4 different item categories. A repeated-measures analysis of variance was run to identify impact of different item categories on performance accuracy in both the experimental groups. Moreover, SPT scores were correlated with neuropsychological test scores in a broad range of other cognitive domains. Finally, diagnostic accuracy of the SPT was calculated by a receiver-operating characteristic curve analysis. Results revealed a global symbol processing dysfunction in AD that was associated with semantic memory and executive deficits. Moreover, AD patients showed a disproportional performance decline at SPT items with visual distraction. Finally, the SPT total score showed high sensitivity and specificity in differentiating between AD patients and healthy controls. The present findings suggest that specific symbol features impede symbol processing in AD and argue for a diagnostic benefit of the SPT in neuropsychological assessment.
Driving and off-road impairments underlying failure on road testing in Parkinson's disease.
Devos, Hannes; Vandenberghe, Wim; Tant, Mark; Akinwuntan, Abiodun E; De Weerdt, Willy; Nieuwboer, Alice; Uc, Ergun Y
2013-12-01
Parkinson's disease (PD) affects driving ability. We aimed to determine the most critical impairments in specific road skills and in clinical characteristics leading to failure on a road test in PD. In this cross-sectional study, certified driving assessment experts evaluated specific driving skills in 104 active, licensed drivers with PD using a standardized, on-road checklist and issued a global decision of pass/fail. Participants also completed an off-road evaluation assessing demographic features, disease characteristics, motor function, vision, and cognition. The most important driving skills and off-road predictors of the pass/fail outcome were identified using multivariate stepwise regression analyses. Eighty-six (65%) passed and 36 (35%) failed the on-road driving evaluation. Persons who failed performed worse on all on-road items. When adjusted for age and gender, poor performances on lateral positioning at low speed, speed adaptations at high speed, and left turning maneuvers yielded the best model that determined the pass/fail decision (R(2) = 0.56). The fail group performed poorer on all motor, visual, and cognitive tests. Measures of visual scanning, motor severity, PD subtype, visual acuity, executive functions, and divided attention were independent predictors of pass/fail decisions in the multivariate model (R(2) = 0.60). Our study demonstrated that failure on a road test in PD is determined by impairments in specific driving skills and associated with deficits in motor, visual, executive, and visuospatial functions. These findings point to specific driving and off-road impairments that can be targeted in multimodal rehabilitation programs for drivers with PD. © 2013 Movement Disorder Society.
de Groot, Maartje H.; van Campen, Jos P.; Beijnen, Jos H.; Hortobágyi, Tibor; Vuillerme, Nicolas; Lamoth, Claudine C. J.
2017-01-01
Fall prediction in geriatric patients remains challenging because the increased fall risk involves multiple, interrelated factors caused by natural aging and/or pathology. Therefore, we used a multi-factorial statistical approach to model categories of modifiable fall risk factors among geriatric patients to identify fallers with highest sensitivity and specificity with a focus on gait performance. Patients (n = 61, age = 79; 41% fallers) underwent extensive screening in three categories: (1) patient characteristics (e.g., handgrip strength, medication use, osteoporosis-related factors) (2) cognitive function (global cognition, memory, executive function), and (3) gait performance (speed-related and dynamic outcomes assessed by tri-axial trunk accelerometry). Falls were registered prospectively (mean follow-up 8.6 months) and one year retrospectively. Principal Component Analysis (PCA) on 11 gait variables was performed to determine underlying gait properties. Three fall-classification models were then built using Partial Least Squares–Discriminant Analysis (PLS-DA), with separate and combined analyses of the fall risk factors. PCA identified ‘pace’, ‘variability’, and ‘coordination’ as key properties of gait. The best PLS-DA model produced a fall classification accuracy of AUC = 0.93. The specificity of the model using patient characteristics was 60% but reached 80% when cognitive and gait outcomes were added. The inclusion of cognition and gait dynamics in fall classification models reduced misclassification. We therefore recommend assessing geriatric patients’ fall risk using a multi-factorial approach that incorporates patient characteristics, cognition, and gait dynamics. PMID:28575126
Kikkert, Lisette H J; de Groot, Maartje H; van Campen, Jos P; Beijnen, Jos H; Hortobágyi, Tibor; Vuillerme, Nicolas; Lamoth, Claudine C J
2017-01-01
Fall prediction in geriatric patients remains challenging because the increased fall risk involves multiple, interrelated factors caused by natural aging and/or pathology. Therefore, we used a multi-factorial statistical approach to model categories of modifiable fall risk factors among geriatric patients to identify fallers with highest sensitivity and specificity with a focus on gait performance. Patients (n = 61, age = 79; 41% fallers) underwent extensive screening in three categories: (1) patient characteristics (e.g., handgrip strength, medication use, osteoporosis-related factors) (2) cognitive function (global cognition, memory, executive function), and (3) gait performance (speed-related and dynamic outcomes assessed by tri-axial trunk accelerometry). Falls were registered prospectively (mean follow-up 8.6 months) and one year retrospectively. Principal Component Analysis (PCA) on 11 gait variables was performed to determine underlying gait properties. Three fall-classification models were then built using Partial Least Squares-Discriminant Analysis (PLS-DA), with separate and combined analyses of the fall risk factors. PCA identified 'pace', 'variability', and 'coordination' as key properties of gait. The best PLS-DA model produced a fall classification accuracy of AUC = 0.93. The specificity of the model using patient characteristics was 60% but reached 80% when cognitive and gait outcomes were added. The inclusion of cognition and gait dynamics in fall classification models reduced misclassification. We therefore recommend assessing geriatric patients' fall risk using a multi-factorial approach that incorporates patient characteristics, cognition, and gait dynamics.
Computer Drawing Method for Operating Characteristic Curve of PV Power Plant Array Unit
NASA Astrophysics Data System (ADS)
Tan, Jianbin
2018-02-01
According to the engineering design of large-scale grid-connected photovoltaic power stations and the research and development of many simulation and analysis systems, it is necessary to draw a good computer graphics of the operating characteristic curves of photovoltaic array elements and to propose a good segmentation non-linear interpolation algorithm. In the calculation method, Component performance parameters as the main design basis, the computer can get 5 PV module performances. At the same time, combined with the PV array series and parallel connection, the computer drawing of the performance curve of the PV array unit can be realized. At the same time, the specific data onto the module of PV development software can be calculated, and the good operation of PV array unit can be improved on practical application.
Tafiadis, Dionysios; Chronopoulos, Spyridon K; Kosma, Evangelia I; Voniati, Louiza; Raptis, Vasilis; Siafaka, Vasiliki; Ziavra, Nausica
2017-07-11
Voice performance is an inextricable key factor of everyday life. Obviously, the deterioration of voice quality can cause various problems to human communication and can therefore reduce the performance of social skills (relevant to voice). The deterioration could be originated from changes inside the system of the vocal tract and larynx. Various prognostic methods exist, and among them is the Voice Handicap Index (VHI). This tool includes self-reported questionnaires, used for determining the cutoff points of total score and of its three domains relevant to young male Greek smokers. The interpretation of the calculated cutoff points can serve as a strong indicator of imminent or future evaluation by a clinician. Consistent with previous calculation, the VHI can also act as a feedback for smokers' voice condition and as monitoring procedure toward smoking cessation. Specifically, the sample consisted of 130 male nondysphonic smokers (aged 18-33 years) who all participated in the VHI test procedure. The test results (through receiver operating characteristic analysis) concluded to a total cutoff point score of 19.50 (sensitivity: 0.838, 1-specificity: 0). Also, in terms of constructs, the Functional domain was equal to 7.50 (sensitivity: 0.676, 1-specificity: 0.032), the Physical domain was equal to 7.50 (sensitivity: 0.706, 1-specificity: 0.032), and the Emotional domain was equal to 6.50 (sensitivity: 0.809, 1-specificity: 0.048). Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Effects of the removal of vision on body sway during different postures in elite gymnasts.
Asseman, F; Caron, O; Crémieux, J
2005-03-01
The aim of this study was to analyse the effects of the removal of vision on postural performance and postural control in function of the difficulty and specificity of the posture. Twelve elite gymnasts were instructed to be as stable as possible with eyes open and eyes closed in three postures: bipedal, unipedal, and handstand ranked from the less difficult and less specific to the more difficult and more specific. The ratios eyes closed on eyes open, computed on CP surface and CP mean velocity, which respectively represents postural performance and postural control, were similar in the bipedal and handstand postures. They were highly increased in the unipedal one. The effect of the removal of vision and so the role of vision on body sway was not directly linked to the difficulty or specificity of the posture; other tasks' characteristics like the segments configuration also played a role.
15 CFR 960.7 - Amendments to licenses.
Code of Federal Regulations, 2011 CFR
2011-01-01
...) Change of operational control; or (4) Deviation from orbital characteristics, performance specifications... of the operations of the system to a foreign person or nation, pursuant to paragraph (a)(2) of this... of the foreign person(s) or nation(s) who will acquire control; (ii) The licensee's proposed plan to...
Man's Search: English, Mythology. 5112.22.
ERIC Educational Resources Information Center
Gundersheimer, Lenore C.
A course which is an exploration of man's eternal search to understand himself and his world through the study of the mythology of the world is presented. Performance objectives include: (1) Students will recognize the content of the myths studied; (2) Students will identify the specific characteristics of the civilization studied; (3) Students…
ERIC Educational Resources Information Center
Ollendick, Thomas H.; Lewis, Krystal M.; Cowart, Maria J. W.; Davis, Thompson, III
2012-01-01
A host of factors including genetic influences, temperament characteristics, learning experiences, information processing biases, parental psychopathology, and specific parenting practices have been hypothesized to contribute to the development and expression of children's phobias. In the present study, the authors focused on parental…
Project Update: Increased Fuel Affordability through Deployable Refining Technology
2016-08-01
gal of jet fuel to meet fit- for-purpose specifications for ultra-low sulfur diesel (< 15 ppm S). The treated fuel will be utilized in a ~40-hr...engine test to verify operating performance characteristics. Follow-on field demonstration opportunities may include treatment of overseas diesel fuel
Interim Guidelines for Growing Longleaf Seedlings in Containers
James P. Barnett; Mark J. Hainds; George A. Hernandez
2002-01-01
The demand for container longleaf pine (Pinus palustris Mill.) planting stock continues to increase each year. A problem facing both producers and users of container seedlings is the lack of target seedling specifications. Outplanting and evaluating performance of seedlings with a range of physiological and morphological characteristics, over a...
40 CFR 270.23 - Specific part B information requirements for miscellaneous units.
Code of Federal Regulations, 2010 CFR
2010-07-01
... requirements for miscellaneous units. 270.23 Section 270.23 Protection of Environment ENVIRONMENTAL PROTECTION... characteristics, materials of construction, and dimensions of the unit; (2) Detailed plans and engineering reports... address and ensure compliance of the unit with each factor in the environmental performance standards of...
Gait Characteristic Analysis and Identification Based on the iPhone's Accelerometer and Gyrometer
Sun, Bing; Wang, Yang; Banda, Jacob
2014-01-01
Gait identification is a valuable approach to identify humans at a distance. In this paper, gait characteristics are analyzed based on an iPhone's accelerometer and gyrometer, and a new approach is proposed for gait identification. Specifically, gait datasets are collected by the triaxial accelerometer and gyrometer embedded in an iPhone. Then, the datasets are processed to extract gait characteristic parameters which include gait frequency, symmetry coefficient, dynamic range and similarity coefficient of characteristic curves. Finally, a weighted voting scheme dependent upon the gait characteristic parameters is proposed for gait identification. Four experiments are implemented to validate the proposed scheme. The attitude and acceleration solutions are verified by simulation. Then the gait characteristics are analyzed by comparing two sets of actual data, and the performance of the weighted voting identification scheme is verified by 40 datasets of 10 subjects. PMID:25222034
He, Xiaoli; Yoo, Joung Eun; Lee, Min Ho; Bae, Joonho
2017-06-16
In this work, the morphology of ZnO nanostructures is engineered to demonstrate enhanced supercapacitor characteristics of ZnO nanocones (NCs) compared to ZnO nanowires (NWs). ZnO NCs are obtained by chemically etching ZnO NWs. Electrochemical characteristics of ZnO NCs and NWs are extensively investigated to demonstrate morphology dependent capacitive performance of one dimensional ZnO nanostructures. Cyclic voltammetry measurements on these two kinds of electrodes in a three-electrode cell confirms that ZnO NCs exhibit a high specific capacitance of 378.5 F g -1 at a scan rate of 20 mV s -1 , which is almost twice that of ZnO NWs (191.5 F g -1 ). The charge-discharge and electrochemical impedance spectroscopy measurements also clearly result in enhanced capacitive performance of NCs as evidenced by higher specific capacitances and lower internal resistance. Asymmetric supercapacitors are fabricated using activated carbon (AC) as the negative electrode and ZnO NWs and NCs as positive electrodes. The ZnO NC⫽AC can deliver a maximum specific capacitance of 126 F g -1 at a current density of 1.33 A g -1 with an energy density of 25.2 W h kg -1 at the power density of 896.44 W kg -1 . In contrast, ZnO NW⫽AC displays 63% of the capacitance obtained from the ZnO NC⫽AC supercapacitor. The enhanced performance of NCs is attributed to the higher surface area of ZnO nanostructures after the morphology is altered from NWs to NCs.
NASA Astrophysics Data System (ADS)
He, Xiaoli; Yoo, Joung Eun; Lee, Min Ho; Bae, Joonho
2017-06-01
In this work, the morphology of ZnO nanostructures is engineered to demonstrate enhanced supercapacitor characteristics of ZnO nanocones (NCs) compared to ZnO nanowires (NWs). ZnO NCs are obtained by chemically etching ZnO NWs. Electrochemical characteristics of ZnO NCs and NWs are extensively investigated to demonstrate morphology dependent capacitive performance of one dimensional ZnO nanostructures. Cyclic voltammetry measurements on these two kinds of electrodes in a three-electrode cell confirms that ZnO NCs exhibit a high specific capacitance of 378.5 F g-1 at a scan rate of 20 mV s-1, which is almost twice that of ZnO NWs (191.5 F g-1). The charge-discharge and electrochemical impedance spectroscopy measurements also clearly result in enhanced capacitive performance of NCs as evidenced by higher specific capacitances and lower internal resistance. Asymmetric supercapacitors are fabricated using activated carbon (AC) as the negative electrode and ZnO NWs and NCs as positive electrodes. The ZnO NC⫽AC can deliver a maximum specific capacitance of 126 F g-1 at a current density of 1.33 A g-1 with an energy density of 25.2 W h kg-1 at the power density of 896.44 W kg-1. In contrast, ZnO NW⫽AC displays 63% of the capacitance obtained from the ZnO NC⫽AC supercapacitor. The enhanced performance of NCs is attributed to the higher surface area of ZnO nanostructures after the morphology is altered from NWs to NCs.
Novel in Vitro Modification of Bone for an Allograft with Improved Toughness Osteoconductivity
2014-04-01
of bone-characteristic genes, osteocalcin, Runx2, and col1a1 by RT-PCR. High-performance liquid chromatography and fluorescence microscopy will be...of molecular markers of mineralization, osteocalcin, Runx2 and col1a1 using quantitative RT-PCR with specific primers. (Months 8-15.) The purpose...bone specific Collagen, type I, alpha 1 ( COL1A1 ) Associated with cell adhesion, proliferation and differentiation of the osteoblast phenotype and
Bueno, I J M; Surek, D; Rocha, C; Schramm, V G; Muramatsu, K; Dahlke, F; Maiorka, A
2016-04-01
An experiment was conducted to test the hypothesis that a coarse limestone diet improves productivity, reproductive performance and the calcium utilization of molted broiler breeders. In total, 640 broiler breeder females, 73-week-old and sixty-four 27-week-old cockerels, Cobb 500, were evaluated during 10 weeks, according to a randomized block design composed of 4 treatments with 8 replicates each. Treatments consisted of diets with the inclusion of 100% fine limestone-fine PS (0.2 mm GMD-geometric mean diameter); PS1: 30% fine limestone+70% limestone with 1.0 mm GMD; PS2: 30% fine limestone+70% limestone with 2.0 mm GMD; and PS3: 30% fine limestone+70% limestone with 3.0 mm GMD. Calcium retention in the gizzard of the breeders, bone characteristics, and breeder performance, egg characteristics, eggshell quality, incubation performance, chick quality and yield, chick pre-starter live performance, and chick bone characteristics were determined. There was no significant difference (P>0.05) in the rate of lay, percentage of non-settable eggs, egg weight, egg shape index, egg specific gravity, eggshell weight, thickness, and percentage hatchability and egg weight loss of broiler breeders fed with diets with different limestone particle sizes. The chick quality and yield, chick pre-starter live performance, and chick bone characteristics were not affected (P>0.05) by any of the limestone particle sizes. It was concluded that live and reproductive performance parameters of broiler breeders post molting is not affected by limestone particle size in the feed. © 2016 Poultry Science Association Inc.
Darvell, Brain W; Dyson, J E
2005-01-01
The measurement of performance characteristics of dental air turbine handpieces is of interest with respect to product comparisons, standards specifications and monitoring of bearing longevity in clinical service. Previously, however, bulky and expensive laboratory equipment was required. A portable test machine is described for determining three key characteristics of dental air-turbine handpieces: free-running speed, stall torque and bearing resistance. It relies on a special circuit design for performing a hardware integration of a force signal with respect to rotational position, independent of the rate at which the turbine is allowed to turn during both stall torque and bearing resistance measurements. Free-running speed without the introduction of any imbalance can be readily monitored. From the essential linear relationship between torque and speed, dynamic torque and, hence, power, can then be calculated. In order for these measurements to be performed routinely with the necessary precision of location on the test stage, a detailed procedure for ensuring proper gripping of the handpiece is described. The machine may be used to verify performance claims, standard compliance checks should this be established as appropriate, monitor deterioration with time and usage in the clinical environment and for laboratory investigation of design development.
Performance Characteristics of Lithium Ion Prototype Cells for 2003 Mars Sample Return Athena Rover
NASA Technical Reports Server (NTRS)
Ratnakumar, B. V.; Smart, M. C.; Ewell, R.; Surampudi, S.; Marsh, R. A.
2000-01-01
A viewgraph presentation outlines the mission objectives and power subsystem for the Mars Sample Return (MSR) Athena Rover. The NASA-DOD (depth of discharge) Interagency Li Ion program objectives are discussed. Evaluation tests performed at JPL are listed, and test results are shown for the Li-Ion cell initial capacity, charge/discharge capacity, voltage and ratio, specific energy, watt-hour efficiency, and cell voltage at various temperatures.
Vinuesa, Víctor; Navarro, David; Poujois, Sandrine; Zaragoza, Susana; Borrás, Rafael
2016-03-01
The performance of the Abbott Real Time MTB assay for detection of Mycobacterium tuberculosis complex in respiratory specimens was evaluated using a standard culture as the reference. The overall concordance between both methods was 0.95. The assay displayed an excellent sensitivity (100% for smear-positive/92.3% for smear-negative specimens) and specificity (100%). Copyright © 2015 Elsevier Inc. All rights reserved.
Kontis, Kris J; Valcour, Andre; Patel, Ashok; Chen, Andy; Wang, Jan; Chow, Julia; Nayak, Narayan
2006-01-01
It has been reported that in vitro measurement of food-specific IgE can be used to accurately predict food allergy and reduce the risk associated with double-blinded placebo-controlled food challenges (DBPCFC). Our objective was to assess the performance characteristics of the Hycor Turbo-MP quantitative radioimmunoassay for food-specific IgE and to determine this method's comparability to another assay, the Pharmacia ImmunoCAP fluorescence enzyme immunoassay (FEIA). The dynamic range of the Turbo-MP assay is 0.05 to 100 IU/ml, compared to 0.35 to 100 IU/ml for the FEIA. Performance characteristics of the Turbo-MP assay (ie, reproducibility of the calibration curve, within-run precision, total precision, parallelism, and linearity) were determined using samples from the Hycor serum bank. The precision (CV) of IgE calibrator replicates was <10%. The total precision (CV) of the Turbo-MP assay ranged from 8.8% to 18.4% for specific IgE concentrations between 0.28 to 31.4 IU/ml. Testing of serial dilutions of sera with IgE specificities for egg white, cow's milk, codfish, wheat, peanut, and soybean showed that the assay is linear over the entire dynamic range. Serial dilution data (slopes of 1.01 to 1.10) showed parallelism to serial dilutions of the IgE calibrator (slope of 0.96). The Turbo-MP and FEIA methods were both used for quantitative assays of food-specific IgE in 457 serum samples obtained from a clinical reference laboratory. Comparison of specific IgE results by the Turbo-MP and FEIA methods for 6 major food allergens exhibited a slope of 0.99 (0.92 to 1.03) with a correlation coefficient of 0.81.
SeaWiFS Technical Report Series. Volume 22: Prelaunch Acceptance Report for the SeaWiFS Radiometer
NASA Technical Reports Server (NTRS)
Hooker, Stanford B. (Editor); Firestone, Elaine R. (Editor); Acker, James G. (Editor); Barnes, Robert A.; Barnes, William L.; Esaias, Wayne E.; Mcclain, Charles R.
1994-01-01
The final acceptance, or rejection, of the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) will be determined by the instrument's on-orbit operation. There is, however, an extensive set of laboratory measurements describing the operating characteristics of the radiometer. Many of the requirements in the Ocean Color Data Mission (OCDM) specifications can be checked only by laboratory measurements. Here, the calibration review panel examines the laboratory characterization and calibration of SeaWiFS in the light of the OCDM performance specification. Overall, the performance of the SeaWiFS instrument meets or exceeds the requirements of the OCDM contract in all but a few unimportant details. The detailed results of this examination are presented here by following the outline of the specifications, as found in the Contract. The results are presented in the form of requirements and compliance pairs. These results give conclusions on many, but not all, of the performance specifications. The acceptance by this panel of the performance of SeaWiFS must only be considered as an intermediate conclusion. The ultimate acceptance (or rejection) of the SeaWiFS data set will rely on the measurements made by the instrument on orbit.
A multi‐centre evaluation of nine rapid, point‐of‐care syphilis tests using archived sera
Herring, A J; Ballard, R C; Pope, V; Adegbola, R A; Changalucha, J; Fitzgerald, D W; Hook, E W; Kubanova, A; Mananwatte, S; Pape, J W; Sturm, A W; West, B; Yin, Y P; Peeling, R W
2006-01-01
Objectives To evaluate nine rapid syphilis tests at eight geographically diverse laboratory sites for their performance and operational characteristics. Methods Tests were compared “head to head” using locally assembled panels of 100 archived (50 positive and 50 negative) sera at each site using as reference standards the Treponema pallidum haemagglutination or the T pallidum particle agglutination test. In addition inter‐site variation, result stability, test reproducibility and test operational characteristics were assessed. Results All nine tests gave good performance relative to the reference standard with sensitivities ranging from 84.5–97.7% and specificities from 84.5–98%. Result stability was variable if result reading was delayed past the recommended period. All the tests were found to be easy to use, especially the lateral flow tests. Conclusions All the tests evaluated have acceptable performance characteristics and could make an impact on the control of syphilis. Tests that can use whole blood and do not require refrigeration were selected for further evaluation in field settings. PMID:17118953
Distributed utility technology cost, performance, and environmental characteristics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wan, Y; Adelman, S
1995-06-01
Distributed Utility (DU) is an emerging concept in which modular generation and storage technologies sited near customer loads in distribution systems and specifically targeted demand-side management programs are used to supplement conventional central station generation plants to meet customer energy service needs. Research has shown that implementation of the DU concept could provide substantial benefits to utilities. This report summarizes the cost, performance, and environmental and siting characteristics of existing and emerging modular generation and storage technologies that are applicable under the DU concept. It is intended to be a practical reference guide for utility planners and engineers seeking informationmore » on DU technology options. This work was funded by the Office of Utility Technologies of the US Department of Energy.« less
Theoretical studies of system performance and adaptive optics design parameters
NASA Astrophysics Data System (ADS)
Tyson, Robert K.
1990-08-01
The ultimate performance of an adaptive optics (AO) system can be sensitive to specific design parameters of individual components. The type and configuration of a wavefront sensor or the shape of individual deformable mirror actuator influence functions can have a profound effect on the correctability of the AO system. This paper will discuss the results of a theoretical study which employed both closed form analytic solutions and computer models. A parametric analysis of wavefront sensor characteristics, noise, and subaperture geometry are independently evaluated against system response to an aberrated wave characteristic of atmospheric turbulence. Similarly, the shape and extent of the deformable mirror influence function and the placement and number of actuators is evaluated to characterize the effects of fitting error and coupling.
Guidance, Navigation, and Control Considerations for Nuclear Thermal Propulsion
NASA Technical Reports Server (NTRS)
Houts, Michael G.; Mitchell, Doyce P.; Kim, Tony
2015-01-01
The fundamental capability of Nuclear Thermal Propulsion (NTP) is game changing for space exploration. A first generation NTP system could provide high thrust at a specific impulse above 900 s, roughly double that of state of the art chemical engines. Characteristics of fission and NTP indicate that useful first generation systems will provide a foundation for future systems with extremely high performance. The role of a first generation NTP in the development of advanced nuclear propulsion systems could be analogous to the role of the DC-3 in the development of advanced aviation. Progress made under the NTP project could also help enable high performance fission power systems and Nuclear Electric Propulsion (NEP). Guidance, navigation, and control of NTP may have some unique but manageable characteristics.
Simulating 2,368 temperate lakes reveals weak coherence in stratification phenology
Read, Jordan S.; Winslow, Luke A.; Hansen, Gretchen J. A.; Van Den Hoek, Jamon; Hanson, Paul C.; Bruce, Louise C; Markfort, Corey D.
2014-01-01
Changes in water temperatures resulting from climate warming can alter the structure and function of aquatic ecosystems. Lake-specific physical characteristics may play a role in mediating individual lake responses to climate. Past mechanistic studies of lake-climate interactions have simulated generic lake classes at large spatial scales or performed detailed analyses of small numbers of real lakes. Understanding the diversity of lake responses to climate change across landscapes requires a hybrid approach that couples site-specific lake characteristics with broad-scale environmental drivers. This study provides a substantial advancement in lake ecosystem modeling by combining open-source tools with freely available continental-scale data to mechanistically model daily temperatures for 2,368 Wisconsin lakes over three decades (1979-2011). The model accurately predicted observed surface layer temperatures (RMSE: 1.74°C) and the presence/absence of stratification (81.1% agreement). Among-lake coherence was strong for surface temperatures and weak for the timing of stratification, suggesting individual lake characteristics mediate some - but not all - ecologically relevant lake responses to climate.
Microbial enzymes with special characteristics for biotechnological applications.
Nigam, Poonam Singh
2013-08-23
This article overviews the enzymes produced by microorganisms, which have been extensively studied worldwide for their isolation, purification and characterization of their specific properties. Researchers have isolated specific microorganisms from extreme sources under extreme culture conditions, with the objective that such isolated microbes would possess the capability to bio-synthesize special enzymes. Various Bio-industries require enzymes possessing special characteristics for their applications in processing of substrates and raw materials. The microbial enzymes act as bio-catalysts to perform reactions in bio-processes in an economical and environmentally-friendly way as opposed to the use of chemical catalysts. The special characteristics of enzymes are exploited for their commercial interest and industrial applications, which include: thermotolerance, thermophilic nature, tolerance to a varied range of pH, stability of enzyme activity over a range of temperature and pH, and other harsh reaction conditions. Such enzymes have proven their utility in bio-industries such as food, leather, textiles, animal feed, and in bio-conversions and bio-remediations.
NASA Astrophysics Data System (ADS)
Arns, James A.
2016-08-01
The Subaru Prime Focus Spectrograph[1] (PFS) requires a suite of volume phase holographic (VPH) gratings that parse the observational spectrum into three sub-spectral regions. In addition, the red region has a second, higher resolution arm that includes a VPH grating that will eventually be incorporated into a grism. This paper describes the specifications of the four grating types, gives the theoretical performances of diffraction efficiency for the production designs and presents the measured performances on the gratings produced to date.
JT8D engine performance retention
NASA Technical Reports Server (NTRS)
James, A. D.; Weisel, D. R.
1981-01-01
The attractive performance retention characteristics of the JT8D engine are described. Because of its moderate bypass ratio and turbine temperature, and stiff structural design, the performance retention versus flight cycles of the JT8D engine sets a standard that is difficult for other engines to equal. In addition, the significant benefits of refurbishment of the JT8D engine are presented. Cold section refurbishment offers thrust specific fuel consumption improvements of up to 2 percent and payback in less than a year, making a very attractive investment option for the airlines.
Draft Plan to Develop Non-Intrusive Load Monitoring Test Protocols
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mayhorn, Ebony T.; Sullivan, Greg P.; Petersen, Joseph M.
2015-09-29
This document presents a Draft Plan proposed to develop a common test protocol that can be used to evaluate the performance requirements of Non-Intrusive Load Monitoring. Development on the test protocol will be focused on providing a consistent method that can be used to quantify and compare the performance characteristics of NILM products. Elements of the protocols include specifications for appliances to be used, metrics, instrumentation, and a procedure to simulate appliance behavior during tests. In addition, three priority use cases for NILM will be identified and their performance requirements will specified.
Talent in Female Gymnastics: a Survival Analysis Based upon Performance Characteristics.
Pion, J; Lenoir, M; Vandorpe, B; Segers, V
2015-11-01
This study investigated the link between the anthropometric, physical and motor characteristics assessed during talent identification and dropout in young female gymnasts. 3 cohorts of female gymnasts (n=243; 6-9 years) completed a test battery for talent identification. Performance-levels were monitored over 5 years of competition. Kaplan-Meier and Cox Proportional Hazards analyses were conducted to determine the survival rate and the characteristics that influence dropout respectively. Kaplan-Meier analysis indicated that only 18% of the female gymnasts that passed the baseline talent identification test survived at the highest competition level 5 years later. The Cox Proportional Hazards Model indicated that gymnasts with a score in the best quartile for a specific characteristic significantly increased chances of survival by 45-129%. These characteristics being: basic motor skills (129%), shoulder strength (96%), leg strength (53%) and 3 gross motor coordination items (45-73%). These results suggest that tests batteries commonly used for talent identification in young female gymnasts may also provide valuable insights into future dropout. Therefore, multidimensional test batteries deserve a prominent place in the selection process. The individual test results should encourage trainers to invest in an early development of basic physical and motor characteristics to prevent attrition. © Georg Thieme Verlag KG Stuttgart · New York.
Azabou, Eric; Fischer, Catherine; Mauguiere, François; Vaugier, Isabelle; Annane, Djillali; Sharshar, Tarek; Lofaso, Fréderic
2016-01-01
We prospectively studied early bedside standard EEG characteristics in 61 acute postanoxic coma patients. Five simple EEG features, namely, isoelectric, discontinuous, nonreactive to intense auditory and nociceptive stimuli, dominant delta frequency, and occurrence of paroxysms were classified yes or no. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under the receiver operating characteristic curve (AUC) of each of these variables for predicting an unfavorable outcome, defined as death, persistent vegetative state, minimally conscious state, or severe neurological disability, as assessed 1 year after coma onset were computed as well as Synek's score. The outcome was unfavorable in 56 (91.8%) patients. Sensitivity, specificity, PPV, NPV, and AUC of nonreactive EEG for predicting an unfavorable outcome were 84%, 80%, 98%, 31%, and 0.82, respectively; and were all very close to the ones of Synek score>3, which were 82%, 80%, 98%, 29%, and 0.81, respectively. Specificities for predicting an unfavorable outcome were 100% for isoelectric, discontinuous, or dominant delta activity EEG. These 3 last features were constantly associated to unfavorable outcome. Absent EEG reactivity strongly predicted an unfavorable outcome in postanoxic coma, and performed as accurate as a Synek score>3. Analyzing characteristics of some simple EEG features may easily help nonneurophysiologist physicians to investigate prognostic issue of postanoxic coma patient. In this study (a) discontinuous, isoelectric, or delta-dominant EEG were constantly associated with unfavorable outcome and (b) nonreactive EEG performed prognostic as accurate as a Synek score>3. © EEG and Clinical Neuroscience Society (ECNS) 2015.
Boehnke, Mitchell; Patel, Nayana; McKinney, Kristin; Clark, Toshimasa
The Society of Radiologists in Ultrasound (SRU 2005) and American Thyroid Association (ATA 2009 and ATA 2015) have published algorithms regarding thyroid nodule management. Kwak et al. and other groups have described models that estimate thyroid nodules' malignancy risk. The aim of our study is to use Kwak's model to evaluate the tradeoffs of both sensitivity and specificity of SRU 2005, ATA 2009 and ATA 2015 management algorithms. 1,000,000 thyroid nodules were modeled in MATLAB. Ultrasound characteristics were modeled after published data. Malignancy risk was estimated per Kwak's model and assigned as a binary variable. All nodules were then assessed using the published management algorithms. With the malignancy variable as condition positivity and algorithms' recommendation for FNA as test positivity, diagnostic performance was calculated. Modeled nodule characteristics mimic those of Kwak et al. 12.8% nodules were assigned as malignant (malignancy risk range of 2.0-98%). FNA was recommended for 41% of nodules by SRU 2005, 66% by ATA 2009, and 82% by ATA 2015. Sensitivity and specificity is significantly different (< 0.0001): 49% and 60% for SRU; 81% and 36% for ATA 2009; and 95% and 20% for ATA 2015. SRU 2005, ATA 2009 and ATA 2015 algorithms are used routinely in clinical practice to determine whether thyroid nodule biopsy is indicated. We demonstrate significant differences in these algorithms' diagnostic performance, which result in a compromise between sensitivity and specificity. Copyright © 2017 Elsevier Inc. All rights reserved.
Lang, Jessica; Thomas, Jeffrey L; Bliese, Paul D; Adler, Amy B
2007-04-01
The aims of the present study were twofold: First, in differentiating between specific job characteristics, the authors examined the moderating influence of role clarity on the relationship between job demands and psychological and physical strain. Second, in providing a more comprehensive link between job demands and job performance, the authors examined strain as a mediator of that relationship. Participants were 1,418 Army cadets attending a 35-day assessment center. Survey data were collected on Day 26 of the assessment center and performance ratings were assessed throughout the assessment center period by expert evaluators. Role clarity was found to moderate the job demands-strain relationship. Specifically, cadets experiencing high demands reported less physical and psychological strain when they reported high role clarity. Moreover, psychological strain significantly mediated the demands-performance relationship. Implications are discussed from theoretical and applied perspectives. Copyright (c) 2007 APA, all rights reserved.
System design of ELITE power processing unit
NASA Astrophysics Data System (ADS)
Caldwell, David J.
The Electric Propulsion Insertion Transfer Experiment (ELITE) is a space mission planned for the mid 1990s in which technological readiness will be demonstrated for electric orbit transfer vehicles (EOTVs). A system-level design of the power processing unit (PPU), which conditions solar array power for the arcjet thruster, was performed to optimize performance with respect to reliability, power output, efficiency, specific mass, and radiation hardness. The PPU system consists of multiphased parallel switchmode converters, configured as current sources, connected directly from the array to the thruster. The PPU control system includes a solar array peak power tracker (PPT) to maximize the power delivered to the thruster regardless of variations in array characteristics. A stability analysis has been performed to verify that the system is stable despite the nonlinear negative impedance of the PPU input and the arcjet thruster. Performance specifications are given to provide the required spacecraft capability with existing technology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akcakaya, Murat; Nehorai, Arye; Sen, Satyabrata
Most existing radar algorithms are developed under the assumption that the environment (clutter) is stationary. However, in practice, the characteristics of the clutter can vary enormously depending on the radar-operational scenarios. If unaccounted for, these nonstationary variabilities may drastically hinder the radar performance. Therefore, to overcome such shortcomings, we develop a data-driven method for target detection in nonstationary environments. In this method, the radar dynamically detects changes in the environment and adapts to these changes by learning the new statistical characteristics of the environment and by intelligibly updating its statistical detection algorithm. Specifically, we employ drift detection algorithms to detectmore » changes in the environment; incremental learning, particularly learning under concept drift algorithms, to learn the new statistical characteristics of the environment from the new radar data that become available in batches over a period of time. The newly learned environment characteristics are then integrated in the detection algorithm. Furthermore, we use Monte Carlo simulations to demonstrate that the developed method provides a significant improvement in the detection performance compared with detection techniques that are not aware of the environmental changes.« less
[Occupation-specific illnesses in musicians].
Schuppert, M; Altenmüller, E
1999-12-01
Performance-related disorders in musicians are most often caused by multiple risk factors. They are based on the chronic complex, rapid and forceful work that requires highest precision, as well as on poor ergonomic conditions and psychological strain. Predominantly, the musculo-skeletal system of the upper extremity and the spine is affected by acute or chronic pain syndromes and neurological disorders. Stage fright and psychological tension frequently generate somatoform disorders and may contribute to the chronification of physical disabilities in musicians. Depending on the individual characteristics, the actual professional activity and the specific instrument, the performance-related risk factors and disorders differ widely. Early and regular prevention clearly contributes to a reduction of medical problems in musicians.
The MK VI - A second generation attitude control system
NASA Astrophysics Data System (ADS)
Meredith, P. J.
1986-10-01
The MK VI, a new multipurpose attitude control system for the exoatmospheric attitude control of sounding rocket payloads, is described. The system employs reprogrammable microcomputer memory for storage of basic control logic and for specific mission event control data. The paper includes descriptions of MK VI specifications and configuration; sensor characteristics; the electronic, analog, and digital sections; the pneumatic system; ground equipment; the system operation; and software. A review of the MK VI performance for the Comet Halley flight is presented. Block diagrams are included.
NASA Lewis and Ohio Company Hit Hole in One
NASA Technical Reports Server (NTRS)
1998-01-01
Ben Hogan Company's Golf Ball Division, which is based in Elyria, Ohio, had developed concepts and prototypes for new golf balls but was unable to determine exact performance characteristics. Specifically, the company's R&D department wanted to measure the spin rates of experimental golf balls. After the Golf Ball Division requested assistance, researchers and technicians from the NASA Lewis Research Center went to Elyria and conducted several days worth of tests. Ben Hogan is using the test results to improve the spin characteristics of a new ball it plans to introduce to the market.
Sattler, Sebastian; Forlini, Cynthia; Racine, Éric; Sauer, Carsten
2013-01-01
Enhancing cognitive performance with substances–especially prescription drugs–is a fiercely debated topic among scholars and in the media. The empirical basis for these discussions is limited, given that the actual nature of factors that influence the acceptability of and willingness to use cognitive enhancement substances remains unclear. In an online factorial survey, contextual and substance-specific characteristics of substances that improve academic performance were varied experimentally and presented to respondents. Students in four German universities rated their willingness to use and moral acceptance of different substances for cognitive enhancement. We found that the overall willingness to use performance enhancing substances is low. Most respondents considered the use of these substances as morally unacceptable. Situational influences such as peer pressure, policies concerning substance use, relative performance level of peers, but also characteristics of the substance, such as perceptions of substance safety, shape the willingness and acceptability of using a substance to enhance academic performance. Among the findings is evidence of a contagion effect meaning that the willingness was higher when the respondents have more CE drug users in their social network. We also found deterrence effects from strong side effects of using the substance, as well as from policy regulations and sanctions. Regulations might activate social norms against usage and sanctions can be seen as costly to users. Moreover, enhancement substances seem to be most tempting to low performers to catch up with others compared to high performers. By identifying contextual factors and substance characteristics influencing the willingness and acceptability of cognitive enhancers, policy approaches could consider these insights to better manage the use of such substances. PMID:23940757
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thien, Mike G.; Barnes, Steve M.
2013-07-01
The Hanford Tank Operations Contractor (TOC) and the Hanford Waste Treatment and Immobilization Plant (WTP) contractor are both engaged in demonstrating mixing, sampling, and transfer system capabilities using simulated Hanford High-Level Waste (HLW) formulations. This represents one of the largest remaining technical issues with the high-level waste treatment mission at Hanford. Previous testing has focused on very specific TOC or WTP test objectives and consequently the simulants were narrowly focused on those test needs. A key attribute in the Defense Nuclear Facilities Safety Board (DNFSB) Recommendation 2010-2 is to ensure testing is performed with a simulant that represents the broadmore » spectrum of Hanford waste. The One System Integrated Project Team is a new joint TOC and WTP organization intended to ensure technical integration of specific TOC and WTP systems and testing. A new approach to simulant definition has been mutually developed that will meet both TOC and WTP test objectives for the delivery and receipt of HLW. The process used to identify critical simulant characteristics, incorporate lessons learned from previous testing, and identify specific simulant targets that ensure TOC and WTP testing addresses the broad spectrum of Hanford waste characteristics that are important to mixing, sampling, and transfer performance are described. (authors)« less
S.S.T.O. performance assessment with in-flight lox collection
NASA Astrophysics Data System (ADS)
Vandenkerckhove, J.; Czysz, P.
1995-10-01
Much attention has recently been given, up to harware development to in-flight oxygen collection as a means to improve considerably the performance of both TSTO & SSTO vehicles. A first assessment suggests that it permits simultaneously to improve much both gross take-off weight (by more than 30%) & dry weight (by more than 15%) of an SSTO and to lower significantly the Mach number of transition scramjet → rocket, from 15 down below 10, thereby reducing dramatically the programmatic development risks. After having compared in-flight lox collection with other SSTO concepts, this paper provides a tentative assessment of the performance of SSTO vehicles taking advantage of it, in particular their sensitivity to changes in system characteristics such as transition Mach number, vehicle slenderness (i.e. Küchemann's parameter τ) or planform loading at take-off and in collection characteristics, in particular collection ratio & specific collection plant weight.
Scalability Analysis of Gleipnir: A Memory Tracing and Profiling Tool, on Titan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Janjusic, Tommy; Kartsaklis, Christos; Wang, Dali
2013-01-01
Application performance is hindered by a variety of factors but most notably driven by the well know CPU-memory speed gap (also known as the memory wall). Understanding application s memory behavior is key if we are trying to optimize performance. Understanding application performance properties is facilitated with various performance profiling tools. The scope of profiling tools varies in complexity, ease of deployment, profiling performance, and the detail of profiled information. Specifically, using profiling tools for performance analysis is a common task when optimizing and understanding scientific applications on complex and large scale systems such as Cray s XK7. This papermore » describes the performance characteristics of using Gleipnir, a memory tracing tool, on the Titan Cray XK7 system when instrumenting large applications such as the Community Earth System Model. Gleipnir is a memory tracing tool built as a plug-in tool for the Valgrind instrumentation framework. The goal of Gleipnir is to provide fine-grained trace information. The generated traces are a stream of executed memory transactions mapped to internal structures per process, thread, function, and finally the data structure or variable. Our focus was to expose tool performance characteristics when using Gleipnir with a combination of an external tools such as a cache simulator, Gl CSim, to characterize the tool s overall performance. In this paper we describe our experience with deploying Gleipnir on the Titan Cray XK7 system, report on the tool s ease-of-use, and analyze run-time performance characteristics under various workloads. While all performance aspects are important we mainly focus on I/O characteristics analysis due to the emphasis on the tools output which are trace-files. Moreover, the tool is dependent on the run-time system to provide the necessary infrastructure to expose low level system detail; therefore, we also discuss any theoretical benefits that can be achieved if such modules were present.« less
Criteria for the selection of a solid phase to be used in immunoassays.
Delagneau, J F; Masseyeff, R
1990-01-01
Heterogeneous immunoassays are very sensitive and only limited in terms of performance by non specific binding. They require separation of free from bound fractions and concomitant use of a solid phase coated with an immunoreactive component (i.e. immunosorbent). The improvement of these key immunosorbents is crucial and involves a great deal of expertise and capabilities. Specifications differ according to procedure (e.g. capture or competitive assay). Each routinely used solid phase, such as polystyrene wells, porous membrane or dispersible microbeads, presents specific performance characteristics, advantages, and drawbacks. Among the tasks to be implemented are optimization of the spatial orientation of immunological reagents, selection of the surface neutral hydrophilic support, acceleration of reactions by increasing the reactive surface area of the supports, streamlining and simplification of procedural steps. These various aspects are abundantly described and emphasized here.
Experimental characterization of a binary actuated parallel manipulator
NASA Astrophysics Data System (ADS)
Giuseppe, Carbone
2016-05-01
This paper describes the BAPAMAN (Binary Actuated Parallel MANipulator) series of parallel manipulators that has been conceived at Laboratory of Robotics and Mechatronics (LARM). Basic common characteristics of BAPAMAN series are described. In particular, it is outlined the use of a reduced number of active degrees of freedom, the use of design solutions with flexural joints and Shape Memory Alloy (SMA) actuators for achieving miniaturization, cost reduction and easy operation features. Given the peculiarities of BAPAMAN architecture, specific experimental tests have been proposed and carried out with the aim to validate the proposed design and to evaluate the practical operation performance and the characteristics of a built prototype, in particular, in terms of operation and workspace characteristics.
Characterization of the space shuttle reaction control system engine
NASA Technical Reports Server (NTRS)
Wilson, M. S.; Stechman, R. C.; Edelman, R. B.; Fortune, O. F.; Economos, C.
1972-01-01
A computer program was developed and written in FORTRAN 5 which predicts the transient and steady state performance and heat transfer characteristics of a pulsing GO2/GH2 rocket engine. This program predicts the dynamic flow and ignition characteristics which, when combined in a quasi-steady state manner with the combustion and mixing analysis program, will provide the thrust and specific impulse of the engine as a function of time. The program also predicts the transient and steady state heat transfer characteristics of the engine using various cooling concepts. The computer program, test case, and documentation are presented. The program is applicable to any system capable of utilizing the FORTRAN 4 or FORTRAN 5 language.
Core competencies for scientific editors of biomedical journals: consensus statement.
Moher, David; Galipeau, James; Alam, Sabina; Barbour, Virginia; Bartolomeos, Kidist; Baskin, Patricia; Bell-Syer, Sally; Cobey, Kelly D; Chan, Leighton; Clark, Jocalyn; Deeks, Jonathan; Flanagin, Annette; Garner, Paul; Glenny, Anne-Marie; Groves, Trish; Gurusamy, Kurinchi; Habibzadeh, Farrokh; Jewell-Thomas, Stefanie; Kelsall, Diane; Lapeña, José Florencio; MacLehose, Harriet; Marusic, Ana; McKenzie, Joanne E; Shah, Jay; Shamseer, Larissa; Straus, Sharon; Tugwell, Peter; Wager, Elizabeth; Winker, Margaret; Zhaori, Getu
2017-09-11
Scientific editors are responsible for deciding which articles to publish in their journals. However, we have not found documentation of their required knowledge, skills, and characteristics, or the existence of any formal core competencies for this role. We describe the development of a minimum set of core competencies for scientific editors of biomedical journals. The 14 key core competencies are divided into three major areas, and each competency has a list of associated elements or descriptions of more specific knowledge, skills, and characteristics that contribute to its fulfillment. We believe that these core competencies are a baseline of the knowledge, skills, and characteristics needed to perform competently the duties of a scientific editor at a biomedical journal.
Impact of future fuel properties on aircraft engines and fuel systems
NASA Technical Reports Server (NTRS)
Rudey, R. A.; Grobman, J. S.
1978-01-01
From current projections of the availability of high-quality petroleum crude oils, it is becoming increasingly apparent that the specifications for hydrocarbon jet fuels may have to be modified. The problems that are most likely to be encountered as a result of these modifications relate to engine performance, component durability and maintenance, and aircraft fuel-system performance. The effect on engine performance will be associated with changes in specific fuel consumption, ignition at relight limits, at exhaust emissions. Durability and maintenance will be affected by increases in combustor liner temperatures, carbon deposition, gum formation in fuel nozzles, and erosion and corrosion of turbine blades and vanes. Aircraft fuel-system performance will be affected by increased deposits in fuel-system heat exchangers and changes in the pumpability and flowability of the fuel. The severity of the potential problems is described in terms of the fuel characteristics most likely to change in the future. Recent data that evaluate the ability of current-technology aircraft to accept fuel specification changes are presented, and selected technological advances that can reduce the severity of the problems are described and discussed.
Performance Charts for a Turbojet System
NASA Technical Reports Server (NTRS)
Karp, Irving M.
1947-01-01
Convenient charts are presented for computing the thrust, fuel consumption, and other performance values of a turbojet system. These charts take into account the effects of ram pressure, compressor pressure ratio, ratio of combustion-chamber-outlet temperature to atmospheric temperature, compressor efficiency, turbine efficiency, combustion efficiency, discharge-nozzle coefficient, losses in total pressure in the inlet to the jet-propulsion unit and in the combustion chamber, and variation in specific heats with temperature. The principal performance charts show clearly the effects of the primary variables and correction charts provide the effects of the secondary variables. The performance of illustrative cases of turbojet systems is given. It is shown that maximum thrust per unit mass rate of air flow occurs at a lower compressor pressure ratio than minimum specific fuel consumption. The thrust per unit mass rate of air flow increases as the combustion-chamber discharge temperature increases. For minimum specific fuel consumption, however, an optimum combustion-chamber discharge temperature exists, which in some cases may be less than the limiting temperature imposed by the strength temperature characteristics of present materials.
Split-Stirling-cycle displacer linear-electric drive
NASA Technical Reports Server (NTRS)
Ackermann, R. A.; Bhate, S. K.; Byrne, D. V.
1983-01-01
The retrofit of a 1/4-W split-Stirling cooler with a linear driven on the displacer was achieved and its performance characterized. The objective of this work was to demonstrate that a small linear motor could be designed to meet the existing envelope specifications of the cooler and that an electric linear drive on the displacer could improve the cooler's reliability and performance. The paper describes the characteristics of this motor and presents cooler test results.
A photoelectric skylight polarimeter.
Hariharan, T A; Sekera, Z
1966-09-01
A photoelectric skylight polarimeter to measure directly the Stokes parameters for plane polarized light is described. The basic principle of the instrument consists in the simultaneous measurement of the intensity of light (in the chosen spectral region) transmitted by polarizers oriented in four specific directions. The main features and performance characteristics of the instrument are briefly discussed.
ERIC Educational Resources Information Center
Sanchez,Gilbert; Cali, Alfred J.
This study was designed to compare time allocations to major functions actually performed and idealized by bilingual administrators and principals; to rank specific procedures used in accomplishing these functions; to determine staffing patterns, and program and organizational characteristics; and to isolate personal/professional demographics of…
77 FR 43506 - DoD Unclassified Controlled Nuclear Information (UCNI)
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-25
... Systems. (i) Information on the layout or design of security and alarm systems at a specific DoD SNM or... information is not observable from a public area. (iii) Performance characteristics of installed systems. (5... 0790-AI64 DoD Unclassified Controlled Nuclear Information (UCNI) AGENCY: Department of Defense. ACTION...
MPD thruster application study
NASA Technical Reports Server (NTRS)
1981-01-01
Developmental considerations for the magneto-plasma-dynamic (MPD) thruster are defined. General characteristics of an MPD engine are compared to those of chemical propulsion and ion bombardment engines and performance criteria which are mission specific are examined. Requirements for thruster ground testing facilities are discussed and the utilization of the space shuttle for an orbital flight test is addressed.
NASA Technical Reports Server (NTRS)
Traversi, M.
1979-01-01
Data are presented on the sensitivity of: (1) mission analysis results to the boundary values given for number of passenger cars and average annual vehicle miles traveled per car; (2) vehicle characteristics and performance to specifications; and (3) tradeoff study results to the expected parameters.
Broad Specification Fuels Combustion Technology Program. Phase 2
1990-10-01
4 4C Where: M is the molecular weight of th hxth specie Nt is the mole fraction of the x specie a is the hydrogen to carbon ratio of the fuel...RATIO F’gure 7-15 Idle Emisions Characteristics of Variable Geometry Cornbusuom geometry combustor configurations as well. The remaining performance
ERIC Educational Resources Information Center
Borella, Erika; Chicherio, Christian; Re, Anna Maria; Sensini, Vanessa; Cornoldi, Cesare
2011-01-01
It has been suggested that intraindividual variability (IIV) in neuropsychological tasks may be a specific characteristic of Attention-Deficit Hyperactivity Disorder (ADHD), but previous research has not thoroughly examined whether IIV also concerns academic performance or other types of developmental disabilities. The present study investigates…
ERIC Educational Resources Information Center
McFarland, Dennis J.
2014-01-01
Purpose: Factor analysis is a useful technique to aid in organizing multivariate data characterizing speech, language, and auditory abilities. However, knowledge of the limitations of factor analysis is essential for proper interpretation of results. The present study used simulated test scores to illustrate some characteristics of factor…
ERIC Educational Resources Information Center
Sawyer, Jr., Thomas P.; Hollis-Sawyer, Lisa A.
2005-01-01
As the classroom and workplace, among other contexts, become more diverse in their population characteristics, the need to be aware of specific factors impacting testing outcome issues correspondingly increases. The focus in this study, among other purposes, was to identify possible interactions between examinee's individual-difference…
Expert Systems: Implications for the Diagnosis and Treatment of Learning Disabilities.
ERIC Educational Resources Information Center
Hofmeister, Alan M.; Lubke, Margaret M.
1988-01-01
The article examines characteristics and present or potential applications of expert systems technology for diagnosis and treatment of learning disabilities. Preliminary findings indicate that expert systems can perform as well as humans in specific areas, and that the process of organizing knowledge bases for expert systems helps clarify existing…
The Language Functioning of Youth at Entry to Residential Treatment
ERIC Educational Resources Information Center
Trout, Alexandra L.; Huscroft-D'Angelo, Jacqueline; DeSalvo, Catherine; Gehringer, Robert
2011-01-01
Although much is known about the behavioral and educational characteristics of youth at entry to residential care, little is known about youth language performance. Given the impact of language deficits on outcomes, this study assessed the specific language skills of 70 adolescents at entry to a residential treatment setting. Results revealed…
Student Misconceptions in Chemical Equilibrium as Related to Cognitive Level and Achievement.
ERIC Educational Resources Information Center
Wheeler, Alan E.; Kass, Heidi
Reported is an investigation to determine the nature and extent of student misconceptions in chemical equilibrium and to ascertain the degree to which certain misconceptions are related to chemistry achievement and to performance on specific tasks involving cognitive transformations characteristic of the concrete and formal operational stages of…
NASA Technical Reports Server (NTRS)
Ingels, F.; Schoggen, W. O.
1981-01-01
The various methods of high bit transition density encoding are presented, their relative performance is compared in so far as error propagation characteristics, transition properties and system constraints are concerned. A computer simulation of the system using the specific PN code recommended, is included.
[BALANCED SCORECARD AS A MANAGEMENT TOOL IN CLINICAL NUTRITION].
Gutiérrez López, Cristina; Mauriz, Jose L; Culebras, Jesús M
2015-07-01
Nowadays, balanced scorecards have updated traditional management systems in the business sector. In this way, Kaplan and Norton propose performance measurement through several perspectives with a logical sequence: internal processes and learning impact client services, so that financial performance is affected. The aim of the present paper is to analyze the main characteristics of balanced scorecard when it is applied to non-for-profit companies and, specifically to the health sector in the clinical nutrition field. This model improves the economic vision of management with clinical indicators that represent healthcare professional's perspective. The balanced scorecard would allow a proper monitoring and tracking system for the main healthcare indicators. This contributes to a better control in comparison with standards that are associated with adequate quality assistance. Owing to the role of management accounting and cost calculations, the definition of healthcare professionals as clients or users, and clinical results relevance, it is necessary to adapt the balanced scorecard to the specific characteristics of the clinical field, redefining both perspectives and indicators. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Elferink-Gemser, Marije; Hartman, Esther; Willemse, Bas; Philippaerts, Renaat; Visscher, Chris; Lenoir, Matthieu
2015-01-01
Objectives The aim of this study was to investigate to what extent 9 to 11 year old children participating in a specific sport already exhibit a specific anthropometric, physical fitness and motor coordination profile, in line with the requirements of that particular sport. In addition, the profiles in children with a different training volume were compared and possible differences in training hours per week between children from a low, moderate, and high level of physical fitness and motor coordination were investigated. Methods and Results Data of 620 children, 347 boys and 273 girls, who participated in the Flemish Sports Compass were used. Only the primary sport of each child was considered and six groups of sports (Ball sports, Dance, Gymnastics, Martial arts, Racquet sports and Swimming) were formed based on common characteristics. Measurements consisted of 17 tests. Independent T-tests and Mann-Whitney U-tests revealed few differences between the groups of sports and the discriminant analyses with the moderate and low active group did not show any significant results (p > .05). However, when discriminating among the high active children, a 85.2 % correct classification between six groups of sports was found (Wilks’ Λ = .137 and p < .001). Finally, children performing under average on the tests spent significantly fewer hours in sport per week (2.50 ± 1.84 hours) compared to the children performing best (3.25 ± 2.60 hours) (p = .016) and the children performing above average (2.90 ± 1.96 hours) (p = .029) on physical fitness and motor coordination. Discussion The study showed that in general, children at a young age do not exhibit sport-specific characteristics, except in children with a high training volume. It is possible that on the one hand, children have not spent enough time yet in their sport to develop sport-specific qualities. On the other hand, it could be possible that they do not take individual qualities into account when choosing a sport. PMID:25978313
Enjeti, Anoop; Granter, Neil; Ashraf, Asma; Fletcher, Linda; Branford, Susan; Rowlings, Philip; Dooley, Susan
2015-10-01
An automated cartridge-based detection system (GeneXpert; Cepheid) is being widely adopted in low throughput laboratories for monitoring BCR-ABL1 transcript in chronic myelogenous leukaemia. This Australian study evaluated the longitudinal performance specific characteristics of the automated system.The automated cartridge-based system was compared prospectively with the manual qRT-PCR-based reference method at SA Pathology, Adelaide, over a period of 2.5 years. A conversion factor determination was followed by four re-validations. Peripheral blood samples (n = 129) with international scale (IS) values within detectable range were selected for assessment. The mean bias, proportion of results within specified fold difference (2-, 3- and 5-fold), the concordance rate of major molecular remission (MMR) and concordance across a range of IS values on paired samples were evaluated.The initial conversion factor for the automated system was determined as 0.43. Except for the second re-validation, where a negative bias of 1.9-fold was detected, all other biases fell within desirable limits. A cartridge-specific conversion factor and efficiency value was introduced and the conversion factor was confirmed to be stable in subsequent re-validation cycles. Concordance with the reference method/laboratory at >0.1-≤10 IS was 78.2% and at ≤0.001 was 80%, compared to 86.8% in the >0.01-≤0.1 IS range. The overall and MMR concordance were 85.7% and 94% respectively, for samples that fell within ± 5-fold of the reference laboratory value over the entire period of study.Conversion factor and performance specific characteristics for the automated system were longitudinally stable in the clinically relevant range, following introduction by the manufacturer of lot specific efficiency values.
Quality of life instruments used in mental health research: properties and utilization.
Prigent, Amélie; Simon, Sandrine; Durand-Zaleski, Isabelle; Leboyer, Marion; Chevreul, Karine
2014-01-30
Quality of life (QoL) assessment is increasingly used in mental health. Multiple instruments exist, but the conditions for choosing one instrument over another for purposes of a specific study are not clear. We performed a systematic review to identify the QoL instruments used in mental health. The instruments were systematically described regarding their intrinsic properties (e.g., generic v. disease-specific) and their characteristics of utilization in studies (e.g., study objectives). Using cluster analyses, we investigated the existence of similar instruments with respect to each of these sets of characteristics and studied potential links between instruments' intrinsic properties and their characteristics of utilization. We included 149 studies in which 56 distinct instruments were used. Similarities were found among instruments in terms of their intrinsic properties as well as their characteristics of utilization, leading to the construction of four clusters of instruments in each case. However, no relevant links were identified between instruments' intrinsic properties and their characteristics of utilization, suggesting that the choice of QoL instruments did not depend on their properties. A consensus about common QoL instruments must be reached to facilitate the choice of instruments, the comparison of results and thus to have an impact on clinical and policy decision-making. © 2013 Published by Elsevier Ireland Ltd.
Ardal, Christine; Alstadsæter, Annette; Røttingen, John-Arne
2011-09-28
Innovation through an open source model has proven to be successful for software development. This success has led many to speculate if open source can be applied to other industries with similar success. We attempt to provide an understanding of open source software development characteristics for researchers, business leaders and government officials who may be interested in utilizing open source innovation in other contexts and with an emphasis on drug discovery. A systematic review was performed by searching relevant, multidisciplinary databases to extract empirical research regarding the common characteristics and barriers of initiating and maintaining an open source software development project. Common characteristics to open source software development pertinent to open source drug discovery were extracted. The characteristics were then grouped into the areas of participant attraction, management of volunteers, control mechanisms, legal framework and physical constraints. Lastly, their applicability to drug discovery was examined. We believe that the open source model is viable for drug discovery, although it is unlikely that it will exactly follow the form used in software development. Hybrids will likely develop that suit the unique characteristics of drug discovery. We suggest potential motivations for organizations to join an open source drug discovery project. We also examine specific differences between software and medicines, specifically how the need for laboratories and physical goods will impact the model as well as the effect of patents.
Anthropometric and performance measures to study talent detection in youth volleyball.
Melchiorri, Giovanni; Viero, Valerio; Triossi, Tamara; Annino, Giuseppe; Padua, Elvira; Tancredi, Virginia
2017-12-01
The aim of this work was to study anthropometric and performance measurements in 60 young male volleyball players (YV) and 60 youth not active in the sport (YNA) to assess which of these would be more useful to study the characteristics of potential performers. Eight measures to assess anthropometric characteristics, six performance measures and two tests for joint mobility were used. Also relative age and level of maturation were assessed. The anthropometric variables, relative age and level of maturation measured did not show statistically significant differences between groups. The YV and YNA groups showed differences in the performance measures. YV group was characterized by a better performance of the ability to repeat short sprints, of the upper limbs, abdominal muscles and lower limbs, with a medium effect size (Shuttle Running Test: 0.6; Push-Up: 0.5; Sit-Up: 0.4; counter movement jump: 0.4). These performance variables were very sensitive and specific: the SRT measurement had the best positive likelihood ratio that indicates the utility of the test in identifying type of players (YV and YNA). In talent detection in youth volleyball, in the 11-13 age range, performance variables should be preferred to anthropometric ones.
The Effects of Low-Level Ethanol Blends in 4-Stroke Small Non-Road Engines
NASA Astrophysics Data System (ADS)
Reek, Chris
Small Non-Road Engines (SNRE's) abound in numbers and are used daily by consumers and businesses alike. Considering the atmosphere of change looming in the air regarding alternative fuels, this particular engine classification will also be affected by any change in standardization of fuels. This body of research attempts to address possible ways SNRE's can change their operational characteristics after being fueled by specific yet differing fuels. These characteristics will be contrasted against blends of ethanol with gasoline, from 0% ethanol to 20% ethanol, run on test engines to determine patterns, if any, of these characteristics. Topics include: materials compatibility, engine longevity/durability, engine performance, emissions characteristics, operational temperatures, engine oil characteristics, and inspection of engines. These parameters will be used to compare the effects of low-level blends of ethanol with gasoline has on these particular SNRE's.
Ezeigwe, Nnenna; Ntadom, Godwin; Oladosu, Oladipo O.; Rainwater-Loveth, Kaitlin; O'Meara, Wendy; Okpokoro, Evaezi; Brieger, William
2016-01-01
ABSTRACT The need to expand malaria diagnosis capabilities alongside policy requirements for mandatory testing before treatment motivates exploration of noninvasive rapid diagnostic tests (RDTs). We report the outcome of the first cross-sectional, single-blind clinical performance evaluation of a urine malaria test (UMT) for diagnosis of Plasmodium falciparum malaria in febrile patients. Matched urine and finger-prick blood samples from participants ≥2 years of age with fever (axillary temperature of ≥37.5°C) or with a history of fever in the preceding 48 h were tested with UMT and microscopy (as the gold standard). BinaxNOW (Pf and Pan versions) blood RDTs were done to assess relative performance. Urinalysis and rheumatoid factor (RF) tests were conducted to evaluate possible interference. Diagnostic performance characteristics were computed at 95% confidence intervals (CIs). Of 1,800 participants screened, 1,691 were enrolled; of these 566 (34%) were febrile, and 1,125 (66%) were afebrile. Among enrolled participants, 341 (20%) tested positive by microscopy, 419 (25%) were positive by UMT, 676 (40%) were positive by BinaxNOW Pf, and 368 (22%) were positive by BinaxNow Pan. UMT sensitivity among febrile patients (for whom the test was indicated) was 85%, and specificity was 84%. Among febrile children ≤5 years of age, UMT sensitivity was 93%, and specificity was 83%. The area under the receiver-operator characteristic curve (AUC) of UMT (0.84) was not significantly different from that of BinaxNOW Pf (0.86) or of BinaxNOW Pan (0.87), indicating that the tests do not differ in overall performance. Gender, seasons, and RF did not impact UMT performance. Leukocytes, hematuria, and urobilinogen concentrations in urine were associated with lower UMT specificities. UMT performance was comparable to that of the BinaxNOW Pf/Pan tests, making UMT a promising tool to expand malaria testing in public and private health care settings where there are challenges to blood-based malaria diagnosis testing. PMID:27847373
Contingent capture of involuntary visual attention interferes with detection of auditory stimuli
Kamke, Marc R.; Harris, Jill
2014-01-01
The involuntary capture of attention by salient visual stimuli can be influenced by the behavioral goals of an observer. For example, when searching for a target item, irrelevant items that possess the target-defining characteristic capture attention more strongly than items not possessing that feature. Such contingent capture involves a shift of spatial attention toward the item with the target-defining characteristic. It is not clear, however, if the associated decrements in performance for detecting the target item are entirely due to involuntary orienting of spatial attention. To investigate whether contingent capture also involves a non-spatial interference, adult observers were presented with streams of visual and auditory stimuli and were tasked with simultaneously monitoring for targets in each modality. Visual and auditory targets could be preceded by a lateralized visual distractor that either did, or did not, possess the target-defining feature (a specific color). In agreement with the contingent capture hypothesis, target-colored distractors interfered with visual detection performance (response time and accuracy) more than distractors that did not possess the target color. Importantly, the same pattern of results was obtained for the auditory task: visual target-colored distractors interfered with sound detection. The decrement in auditory performance following a target-colored distractor suggests that contingent capture involves a source of processing interference in addition to that caused by a spatial shift of attention. Specifically, we argue that distractors possessing the target-defining characteristic enter a capacity-limited, serial stage of neural processing, which delays detection of subsequently presented stimuli regardless of the sensory modality. PMID:24920945
Contingent capture of involuntary visual attention interferes with detection of auditory stimuli.
Kamke, Marc R; Harris, Jill
2014-01-01
The involuntary capture of attention by salient visual stimuli can be influenced by the behavioral goals of an observer. For example, when searching for a target item, irrelevant items that possess the target-defining characteristic capture attention more strongly than items not possessing that feature. Such contingent capture involves a shift of spatial attention toward the item with the target-defining characteristic. It is not clear, however, if the associated decrements in performance for detecting the target item are entirely due to involuntary orienting of spatial attention. To investigate whether contingent capture also involves a non-spatial interference, adult observers were presented with streams of visual and auditory stimuli and were tasked with simultaneously monitoring for targets in each modality. Visual and auditory targets could be preceded by a lateralized visual distractor that either did, or did not, possess the target-defining feature (a specific color). In agreement with the contingent capture hypothesis, target-colored distractors interfered with visual detection performance (response time and accuracy) more than distractors that did not possess the target color. Importantly, the same pattern of results was obtained for the auditory task: visual target-colored distractors interfered with sound detection. The decrement in auditory performance following a target-colored distractor suggests that contingent capture involves a source of processing interference in addition to that caused by a spatial shift of attention. Specifically, we argue that distractors possessing the target-defining characteristic enter a capacity-limited, serial stage of neural processing, which delays detection of subsequently presented stimuli regardless of the sensory modality.
On the practice of ignoring center-patient interactions in evaluating hospital performance.
Varewyck, Machteld; Vansteelandt, Stijn; Eriksson, Marie; Goetghebeur, Els
2016-01-30
We evaluate the performance of medical centers based on a continuous or binary patient outcome (e.g., 30-day mortality). Common practice adjusts for differences in patient mix through outcome regression models, which include patient-specific baseline covariates (e.g., age and disease stage) besides center effects. Because a large number of centers may need to be evaluated, the typical model postulates that the effect of a center on outcome is constant over patient characteristics. This may be violated, for example, when some centers are specialized in children or geriatric patients. Including interactions between certain patient characteristics and the many fixed center effects in the model increases the risk for overfitting, however, and could imply a loss of power for detecting centers with deviating mortality. Therefore, we assess how the common practice of ignoring such interactions impacts the bias and precision of directly and indirectly standardized risks. The reassuring conclusion is that the common practice of working with the main effects of a center has minor impact on hospital evaluation, unless some centers actually perform substantially better on a specific group of patients and there is strong confounding through the corresponding patient characteristic. The bias is then driven by an interplay of the relative center size, the overlap between covariate distributions, and the magnitude of the interaction effect. Interestingly, the bias on indirectly standardized risks is smaller than on directly standardized risks. We illustrate our findings by simulation and in an analysis of 30-day mortality on Riksstroke. © 2015 The Authors. Statistics in Medicine published by John Wiley & Sons Ltd.
Field validation of recombinant antigen immunoassays for diagnosis of Lassa fever.
Boisen, Matthew L; Hartnett, Jessica N; Shaffer, Jeffrey G; Goba, Augustine; Momoh, Mambu; Sandi, John Demby; Fullah, Mohamed; Nelson, Diana K S; Bush, Duane J; Rowland, Megan M; Heinrich, Megan L; Koval, Anatoliy P; Cross, Robert W; Barnes, Kayla G; Lachenauer, Anna E; Lin, Aaron E; Nekoui, Mahan; Kotliar, Dylan; Winnicki, Sarah M; Siddle, Katherine J; Gbakie, Michael; Fonnie, Mbalu; Koroma, Veronica J; Kanneh, Lansana; Kulakosky, Peter C; Hastie, Kathryn M; Wilson, Russell B; Andersen, Kristian G; Folarin, Onikepe O; Happi, Christian T; Sabeti, Pardis C; Geisbert, Thomas W; Saphire, Erica Ollmann; Khan, S Humarr; Grant, Donald S; Schieffelin, John S; Branco, Luis M; Garry, Robert F
2018-04-12
Lassa fever, a hemorrhagic fever caused by Lassa virus (LASV), is endemic in West Africa. It is difficult to distinguish febrile illnesses that are common in West Africa from Lassa fever based solely on a patient's clinical presentation. The field performance of recombinant antigen-based Lassa fever immunoassays was compared to that of quantitative polymerase chain assays (qPCRs) using samples from subjects meeting the case definition of Lassa fever presenting to Kenema Government Hospital in Sierra Leone. The recombinant Lassa virus (ReLASV) enzyme-linked immunosorbant assay (ELISA) for detection of viral antigen in blood performed with 95% sensitivity and 97% specificity using a diagnostic standard that combined results of the immunoassays and qPCR. The ReLASV rapid diagnostic test (RDT), a lateral flow immunoassay based on paired monoclonal antibodies to the Josiah strain of LASV (lineage IV), performed with 90% sensitivity and 100% specificity. ReLASV immunoassays performed better than the most robust qPCR currently available, which had 82% sensitivity and 95% specificity. The performance characteristics of recombinant antigen-based Lassa virus immunoassays indicate that they can aid in the diagnosis of LASV Infection and inform the clinical management of Lassa fever patients.
The ergonomics of learning: educational design and learning performance.
Smith, T J
2007-10-01
The application of ergonomics/human factors (E/HF) principles and practices, and the implementation of ergonomics programmes, have achieved proven success in improving performance, productivity, competitiveness, and safety and health in most occupational sectors. However, the benefits that the application of E/HF science might bring to promoting student learning have yet to be widely recognized. This paper deals with the fundamental purpose of education - student learning - and with the question of how the ergonomic design of the learning environment influences learning performance. The underlying premise, embodied in the quote below, is that student learning performance to a substantial degree is context specific - influenced and specialized in relation to specific design factors in the learning environment. The basic scientific question confronting learning ergonomics is which design characteristics in the learning environment have the greatest influence on variability in learning performance. Practically, the basic challenge is to apply this scientific understanding to ergonomic interventions directed at design improvements of learning environments to benefit learning. This paper expands upon these themes by addressing the origins and scope of learning ergonomics, differing perspectives on the nature of learning, evidence for context specificity in learning and conclusions and research implications regarding an ergonomics perspective on learning.
Are ECG abnormalities in Noonan syndrome characteristic for the syndrome?
Raaijmakers, R; Noordam, C; Noonan, J A; Croonen, E A; van der Burgt, C J A M; Draaisma, J M T
2008-12-01
Of all patients with Noonan syndrome, 50-90% have one or more congenital heart defects. The most frequent occurring are pulmonary stenosis (PS) and hypertrophic cardiomyopathy. The electrocardiogram (ECG) of a patient with Noonan syndrome often shows a characteristic pattern, with a left axis deviation, abnormal R/S ratio over the left precordium, and an abnormal Q wave. The objective of this study was to determine if these ECG characteristics are an independent feature of the Noonan syndrome or if they are related to the congenital heart defect. A cohort study was performed with 118 patients from two university hospitals in the United States and in The Netherlands. All patients were diagnosed with definite Noonan syndrome and had had an ECG and echocardiography. Sixty-nine patients (58%) had characteristic abnormalities of the ECG. In the patient group without a cardiac defect (n = 21), ten patients had a characteristic ECG abnormality. There was no statistical relationship between the presence of a characteristic ECG abnormality and the presence of a cardiac defect (p = 0.33). Patients with hypertrophic cardiomyopathy had more ECG abnormalities in total (p = 0.05), without correlation with a specific ECG abnormality. We conclude that the ECG features in patients with Noonan syndrome are characteristic for the syndrome and are not related to a specific cardiac defect. An ECG is very useful in the diagnosis of Noonan syndrome; every child with a Noonan phenotype should have an ECG and echocardiogram for evaluation.
Finding the music of speech: Musical knowledge influences pitch processing in speech.
Vanden Bosch der Nederlanden, Christina M; Hannon, Erin E; Snyder, Joel S
2015-10-01
Few studies comparing music and language processing have adequately controlled for low-level acoustical differences, making it unclear whether differences in music and language processing arise from domain-specific knowledge, acoustic characteristics, or both. We controlled acoustic characteristics by using the speech-to-song illusion, which often results in a perceptual transformation to song after several repetitions of an utterance. Participants performed a same-different pitch discrimination task for the initial repetition (heard as speech) and the final repetition (heard as song). Better detection was observed for pitch changes that violated rather than conformed to Western musical scale structure, but only when utterances transformed to song, indicating that music-specific pitch representations were activated and influenced perception. This shows that music-specific processes can be activated when an utterance is heard as song, suggesting that the high-level status of a stimulus as either language or music can be behaviorally dissociated from low-level acoustic factors. Copyright © 2015 Elsevier B.V. All rights reserved.
Silva, Richardson Augusto Rosendo da; Costa, Mayara Mirna do Nascimento; Souza, Vinicius Lino de; Silva, Bárbara Coeli Oliveira da; Costa, Cristiane da Silva; Andrade, Itaísa Fernandes Cardoso de
2017-10-30
to evaluate the accuracy of the defining characteristics of the NANDA International nursing diagnosis, noncompliance, in people with HIV. study of diagnostic accuracy, performed in two stages. In the first stage, 113 people with HIV from a hospital of infectious diseases in the Northeast of Brazil were assessed for identification of clinical indicators of noncompliance. In the second, the defining characteristics were evaluated by six specialist nurses, analyzing the presence or absence of the diagnosis. For accuracy of the clinical indicators, the specificity, sensitivity, predictive values and likelihood ratios were measured. the presence of the noncompliance diagnosis was shown in 69% (n=78) of people with HIV. The most sensitive indicator was, missing of appointments (OR: 28.93, 95% CI: 1.112-2.126, p = 0.002). On the other hand, nonadherence behavior (OR: 15.00, 95% CI: 1.829-3.981, p = 0.001) and failure to meet outcomes (OR: 13.41; 95% CI: 1.272-2.508; P = 0.003) achieved higher specificity. the most accurate defining characteristics were nonadherence behavior, missing of appointments, and failure to meet outcomes. Thus, in the presence of these, the nurse can identify, with greater security, the diagnosis studied.
Evaluation of Low Power Hall Thruster Propulsion
NASA Technical Reports Server (NTRS)
Manzella, David; Oleson, Steve; Sankovic, John; Haag, Tom; Semenkin, Alexander; Kim, Vladimir
1996-01-01
Hall thruster systems based on the SPT-50 and the TAL D-38 were evaluated and mission studies were performed. The 0.3 kilowatt SPT-50 operated with a specific impulse of 1160 seconds and an efficiency of 0.32. The 0.8 kilowatt D-38 provided a specific impulse above 1700 seconds at an efficiency of 0.5. The D-38 system was shown to offer a 56 kilogram propulsion system mass savings over a 101 kilogram hydrazine monopropellant system designed to perform North-South station keeping maneuvers on board a 430 kilogram geostationary satellite. The SPIT-50 system offered a greater than 50% propulsion system mass reduction in comparison to the chemical system on board a 200 kilogram low Earth orbit spacecraft performing two orbit raises and drag makeup over two years. The performance characteristics of the SPF-50 were experimentally evaluated at a number of operating conditions. The ion current density distribution of this engine was measured. The performance and system mass benefits of advanced systems based on both engines were considered.
The effects of legacy organization culture on post-merger integration.
Frantz, Terrill L; Carley, Kathleen M
2013-01-01
We explore the relationship between the characteristics of pre-existing organization cultures and post-merger integration dynamics; this study involves examining data produced by computer simulation. Two characteristics of organization culture, its characteristic complexity and its propensity for members' to share information, are controlled in computational experiments. To characterize post-merger integration dynamics, we measure the transfer of information with respect to two types: (a) that which is necessary in performing work tasks, and (b) that which underlies the features of a group's culture. The extent to which this information is common in a group is indicative of task performance and the cultural cohesiveness of its members; leading to the level of performance for the group. We consider cultural knowledge as it pertains to both that of the entire organization and at the work-team level; often times, these can be dissimilar. We find that cultural complexity and exchange motivation vary in their influence on the diffusion of task and cultural knowledge: the more complex the culture, the longer for post-merger integration to complete, while simultaneously task performance suffers. However, the inclination for an organization to energetically share their culture with another group does not immensely impact the diffusion of cultural or task knowledge; moreover, high levels of task focus in a culture can hinder cultural diffusion, though performance is positively correlated with this characteristic. This study has relevance to post-merger integration research and practice by providing a theoretically grounded, quantitative model useful for estimating the post-merger dynamics of cultural awareness and knowledge diffusion for a specific merger situation.
Ball, David A.; Mehta, Gunjan D.; Salomon-Kent, Ronit; Mazza, Davide; Morisaki, Tatsuya; Mueller, Florian; McNally, James G.; Karpova, Tatiana S.
2016-01-01
In vivo single molecule tracking has recently developed into a powerful technique for measuring and understanding the transient interactions of transcription factors (TF) with their chromatin response elements. However, this method still lacks a solid foundation for distinguishing between specific and non-specific interactions. To address this issue, we took advantage of the power of molecular genetics of yeast. Yeast TF Ace1p has only five specific sites in the genome and thus serves as a benchmark to distinguish specific from non-specific binding. Here, we show that the estimated residence time of the short-residence molecules is essentially the same for Hht1p, Ace1p and Hsf1p, equaling 0.12–0.32 s. These three DNA-binding proteins are very different in their structure, function and intracellular concentration. This suggests that (i) short-residence molecules are bound to DNA non-specifically, and (ii) that non-specific binding shares common characteristics between vastly different DNA-bound proteins and thus may have a common underlying mechanism. We develop new and robust procedure for evaluation of adverse effects of labeling, and new quantitative analysis procedures that significantly improve residence time measurements by accounting for fluorophore blinking. Our results provide a framework for the reliable performance and analysis of single molecule TF experiments in yeast. PMID:27566148
Nigg, B M; Stefanyshyn, D; Cole, G; Stergiou, P; Miller, J
2003-04-01
The purposes of this study were (a) to determine group and individual differences in oxygen consumption during heel-toe running and (b) to quantify the differences in EMG activity for selected muscle groups of the lower extremities when running in shoes with different mechanical heel characteristics. Twenty male runners performed heel-toe running using two shoe conditions, one with a mainly elastic and a visco-elastic heel. Oxygen consumption was quantified during steady state runs of 6 min duration, running slightly above the aerobic threshold providing four pairs of oxygen consumption results for comparison. Muscle activity was quantified using bipolar surface EMG measurements from the tibialis anterior, medial gastrocnemius, vastus medialis and the hamstrings muscle groups. EMG data were sampled for 5 s every minute for the 6 min providing 30 trials. EMG data were compared for the different conditions using an ANOVA (alpha=0.05). The findings of this study showed that changes in the heel material characteristics of running shoes were associated with (a) subject specific changes in oxygen consumption and (b) subject and muscle specific changes in the intensities of muscle activation before heel strike in the lower extremities. It is suggested that further study of these phenomena will help understand many aspects of human locomotion, including work, performance, fatigue and possible injuries.
Lewicky-Gaupp, Christina; Blaivas, Jerry; Clark, Amanda; McGuire, Edward J; Schaer, Gabriel; Tumbarello, Julie; Tunn, Ralf; DeLancey, John O L
2009-02-01
This study was carried out to determine whether five experts in female stress urinary incontinence (SUI) could discover a pattern of urethrovesical movement characteristic of SUI on dynamic perineal ultrasound. A secondary analysis of data from a case-control study was performed. Ultrasounds from 31 cases (daily SUI) and 42 controls (continent volunteers) of similar age and parity were analyzed. Perineal ultrasound was performed during a single cough. The five experts, blinded to continence status and urodynamics, classified each woman as stress continent or incontinent. Correct responses ranged from 45.7% to 65.8% (mean 57.4 +/- 7.6). Sensitivity was 53.0 +/- 8.8% and specificity 61.2 +/- 12.4%. The positive predictive value was 48.8 +/- 8.2% and negative predictive value was 65.0 +/- 7.3%. Inter-rater reliability, evaluated by Cohen's kappa statistic, averaged 0.47 [95% CI 0.40-0.50]. Experts could not identify a pattern of urethrovesical movement characteristic of SUI on ultrasound.
Brayton Power Conversion System Parametric Design Modelling for Nuclear Electric Propulsion
NASA Technical Reports Server (NTRS)
Ashe, Thomas L.; Otting, William D.
1993-01-01
The parametrically based closed Brayton cycle (CBC) computer design model was developed for inclusion into the NASA LeRC overall Nuclear Electric Propulsion (NEP) end-to-end systems model. The code is intended to provide greater depth to the NEP system modeling which is required to more accurately predict the impact of specific technology on system performance. The CBC model is parametrically based to allow for conducting detailed optimization studies and to provide for easy integration into an overall optimizer driver routine. The power conversion model includes the modeling of the turbines, alternators, compressors, ducting, and heat exchangers (hot-side heat exchanger and recuperator). The code predicts performance to significant detail. The system characteristics determined include estimates of mass, efficiency, and the characteristic dimensions of the major power conversion system components. These characteristics are parametrically modeled as a function of input parameters such as the aerodynamic configuration (axial or radial), turbine inlet temperature, cycle temperature ratio, power level, lifetime, materials, and redundancy.
LEWICKY-GAUPP, Christina; BLAIVAS, Jerry; CLARK, Amanda; McGUIRE, Edward J.; SCHAER, Gabriel; TUMBARELLO, Julie; TUNN, Ralf; DeLANCEY, John O.L.
2009-01-01
Introduction and Hypothesis To determine if 5 experts in female stress urinary incontinence (SUI) could discover a pattern of urethrovesical movement characteristic of SUI on dynamic perineal ultrasound. Methods A secondary analysis of data from a case-control study was performed. Ultrasounds from 31 cases (daily SUI) and 42 controls (continent volunteers) of similar age and parity were analyzed. Perineal ultrasound was performed during a single cough. The 5 experts, blinded to continence status and urodynamics, classified each woman as stress continent or incontinent. Results Correct responses ranged from 45.7% to 65.8% (mean 57.4 ± 7.6). Sensitivity was 53.0 ± 8.8% and specificity 61.2 ± 12.4%. The positive predictive value was 48.8 ± 8.2% and negative predictive value was 65.0 ± 7.3%. Inter-rater reliability, evaluated by Cohen's kappa statistic, averaged 0.47 [95% CI 0.40 – 0.50]. Conclusions Experts could not identify a pattern of urethrovesical movement characteristic of SUI on ultrasound. PMID:18850057
Sodium-sulfur Cell Technology Flight Experiment (SSCT)
NASA Technical Reports Server (NTRS)
Halbach, Carl R.
1992-01-01
The sodium-sulfur battery is emerging as a prime high-temperature energy storage technology for space flight applications. A Na-S cell demonstration is planned for a 1995-96 NASA Space Shuttle flight which focuses on the microgravity effects on individual cells. The experiment is not optimized for battery performance as such. Rather, it maximizes the variety of operating conditions which the Na-S cell is capable of in a relatively short 5-day flight. The demonstration is designed to reveal the effects of microgravity by comparison with ground test control cells experiencing identical test conditions but with gravity. Specifically, limitations of transport dynamics and associated cell performance characteristics should be revealed. The Na-S Cell Technology Flight Experiment consists of three separate experiments designed to determine cell operating characteristics, detailed electrode kinetics and reactant distributions.
Characteristics of urban transportation systems. A handbook for transportation planners
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1975-05-01
The objective of the handbook, specifically for use by transportation planners in the evaluation of alternative systems, is to provide a single simplified reference source which characterizes the most important performance characteristics of the following contemporary urban transportation systems: (1) rail (commuter, rapid, and light); (2) local bus and bus rapid transit; (3) automobile-highway system (automobiles and other vehicles); (4) pedestrian assistance systems; and (5) activity center systems--people mover systems that have been installed at airports, zoos, amusement parks, etc. The handbook assesses the supply or performance aspect of urban transportation dealing with passenger demand implicitly. Seven supply parameters studiedmore » are: speed, capacity (service volume), operating cost (vehicle), energy consumption (vehicle or source), pollution, capital cost, and accident frequency.« less
The Structure of Performance of a Sport Rock Climber
Magiera, Artur; Roczniok, Robert; Maszczyk, Adam; Czuba, Miłosz; Kantyka, Joanna; Kurek, Piotr
2013-01-01
This study is a contribution to the discussion about the structure of performance of sport rock climbers. Because of the complex and multifaceted nature of this sport, multivariate statistics were applied in the study. The subjects included thirty experienced sport climbers. Forty three variables were scrutinised, namely somatic characteristics, specific physical fitness, coordination abilities, aerobic and anaerobic power, technical and tactical skills, mental characteristics, as well as 2 variables describing the climber’s performance in the OS (Max OS) and RP style (Max RP). The results show that for training effectiveness of advanced climbers to be thoroughly analysed and examined, tests assessing their physical, technical and mental characteristics are necessary. The three sets of variables used in this study explained the structure of performance similarly, but not identically (in 38, 33 and 25%, respectively). They were also complementary to around 30% of the variance. The overall performance capacity of a sport rock climber (Max OS and Max RP) was also evaluated in the study. The canonical weights of the dominant first canonical root were 0.554 and 0.512 for Max OS and Max RP, respectively. Despite the differences between the two styles of climbing, seven variables – the maximal relative strength of the fingers (canonical weight = 0.490), mental endurance (one of scales : The Formal Characteristics of Behaviour–Temperament Inventory (FCB–TI; Strelau and Zawadzki, 1995)) (−0.410), climbing technique (0.370), isometric endurance of the fingers (0.340), the number of errors in the complex reaction time test (−0.319), the ape index (−0.319) and oxygen uptake during arm work at the anaerobic threshold (0.254) were found to explain 77% of performance capacity common to the two styles. PMID:23717360
Cong, Rui; Li, Jing; Wang, Xuejiao
2017-10-01
We determined the diagnostic performance of combinations of shear wave elastography (SWE) and B-mode ultrasound (US) in differentiating malignant from benign breast masses, and we investigated whether performance is affected by mass size. In this prospective study of 315 consecutive patients with 326 breast masses, US and SWE were performed before biopsy. Masses were categorized into two subgroups on the basis of mass size (≤15 mm and >15 mm), and the optimal thresholds for the SWE parameters were determined for each subgroup using receiver operating characteristic curves. The combination proposed here achieved an area under the receiver operating characteristic curve of 0.943, 95.00% sensitivity and 81.18% specificity, which approximated the diagnostic performance of US alone. The performance of the combinations using the subgroups' thresholds did not differ significantly from those based on the entire study group's thresholds, but the optimal thresholds were higher in the subgroup of larger masses. Further research is needed to determine whether mass size affects the performance of combinations of SWE and US. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Bilateral Impedance Control For Telemanipulators
NASA Technical Reports Server (NTRS)
Moore, Christopher L.
1993-01-01
Telemanipulator system includes master robot manipulated by human operator, and slave robot performing tasks at remote location. Two robots electronically coupled so slave robot moves in response to commands from master robot. Teleoperation greatly enhanced if forces acting on slave robot fed back to operator, giving operator feeling he or she manipulates remote environment directly. Main advantage of bilateral impedance control: enables arbitrary specification of desired performance characteristics for telemanipulator system. Relationship between force and position modulated at both ends of system to suit requirements of task.
NASA Technical Reports Server (NTRS)
Hamm, J. R.
1976-01-01
Information is presented on the design, performance, operating characteristics, cost, and development status of coal preparation equipment, combustion equipment, furnaces, low-Btu gasification processes, low-temperature carbonization processes, desulfurization processes, and pollution particulate removal equipment. The information was compiled for use by the various cycle concept leaders in determining the performance, capital costs, energy costs, and natural resource requirements of each of their system configurations.
Biomotor structures in elite female handball players according to performance.
Cavala, Marijana; Rogulj, Nenad; Srhoj, Vatromir; Srhoj, Ljerka; Katić, Ratko
2008-03-01
In order to identify biomotor structures in elite female handball players, factor structures of morphological characteristics and basic motor abilities, and of variables evaluating situation motor abilities of elite female handball players (n = 53) were determined first, followed by determination of differences and relations of the morphological, motor and specific motor space according to handball performance. Factor analysis of 16 morphological measures produced three morphological factors, i.e. factor of absolute voluminosity, i.e. mesoendomorphy, factor of longitudinal skeleton dimensionality, and factor of transverse hand dimensionality. Factor analysis of 15 motor variables yielded five basic motor dimensions, i.e. factor of agility, factor of throwing explosive strength, factor of running explosive strength (sprint), factor of jumping explosive strength and factor of movement frequency rate. Factor analysis of 5 situation motor variables produced two dimensions: factor of specific agility with explosiveness and factor of specific precision with ball manipulation. Analysis of variance yielded greatest differences relative to handball performance in the factor of specific agility and throwing strength, and the factor of basic motoricity that integrates the ability of coordination (agility) with upper extremity throwing explosiveness and lower extremity sprint (30-m sprint) and jumping (standing triple jump). Considering morphological factors, the factor of voluminosity, i.e. mesoendomorphy, which is defined by muscle mass rather than adipose tissue, was found to contribute significantly to the players'performance. Results of regression analysis indicated the handball performance to be predominantly determined by the general specific motor factor based on specific agility and explosiveness, and by the morphological factor based on body mass and volume, i.e. muscle mass. Concerning basic motor abilities, the factor of movement frequency rate, which is associated with the ability of ball manipulation, was observed to predict significantly the handball players' performance.
NASA Astrophysics Data System (ADS)
Zlobina, I. V.; Bekrenev, N. V.; Muldasheva, G. K.
2017-10-01
The change in the performance characteristics of sealing and anti friction materials of pipeline armature exposed to a microwave electromagnetic field of low specific power 4-5 W/cm3 was studied. The dimensional and mass fluoroplastics and the change in the compliance of the sealing rubber were evaluated. It was established that the treatment in a microwave electromagnetic field with a frequency of 2,450 MHz with a specific power of 4-5 W/cm3 for 4 minutes ensures a reduction in the size and mass wear upon contact. Besides, the compliance of the rubber increases by 20-64 %, depending on the degree of deformation of the counter-body — by 55 and 25 %. After microwave treatment in a similar mode, the malleability of the rubber increases by 20-64 %, depending on the degree of deformation.
Beckmann, Else; Minnaert, Alexander
2018-01-01
Gifted students who also have learning disabilities (G/LD) are often overlooked when students are assessed either for giftedness or specific learning disabilities. The cognitive and non-cognitive characteristics of these G/LD students are habitually discussed only briefly alongside identification and intervention issues and, beyond that, the relevance of non-cognitive characteristics is often left unconsidered. Accordingly, this study aims to conduct an in-depth review of the non-cognitive characteristics of these students for identification and intervention purposes. Detailed analysis was performed on 23 publications. High levels of negative emotions, low self-perception, and adverse interpersonal relationships, as well as high levels of motivation, coping skills and perseverance were found among these students. A common characteristic was a high degree of frustration with the academic situation. The study reveals that these students show considerably duality in their non-cognitive characteristics which requires tailored counseling skills to provide effective support for their learning needs. PMID:29731728
Beckmann, Else; Minnaert, Alexander
2018-01-01
Gifted students who also have learning disabilities (G/LD) are often overlooked when students are assessed either for giftedness or specific learning disabilities. The cognitive and non-cognitive characteristics of these G/LD students are habitually discussed only briefly alongside identification and intervention issues and, beyond that, the relevance of non-cognitive characteristics is often left unconsidered. Accordingly, this study aims to conduct an in-depth review of the non-cognitive characteristics of these students for identification and intervention purposes. Detailed analysis was performed on 23 publications. High levels of negative emotions, low self-perception, and adverse interpersonal relationships, as well as high levels of motivation, coping skills and perseverance were found among these students. A common characteristic was a high degree of frustration with the academic situation. The study reveals that these students show considerably duality in their non-cognitive characteristics which requires tailored counseling skills to provide effective support for their learning needs.
100-m Breaststroke Swimming Performance in Youth Swimmers: The Predictive Value of Anthropometrics.
Sammoud, Senda; Nevill, Alan Michael; Negra, Yassine; Bouguezzi, Raja; Chaabene, Helmi; Hachana, Younés
2018-03-16
This study aimed to estimate the optimal body size, limb segment length, and girth or breadth ratios of 100-m breaststroke performance in youth swimmers. In total, 59 swimmers [male: n = 39, age = 11.5 (1.3) y; female: n = 20, age = 12.0 (1.0) y] participated in this study. To identify size/shape characteristics associated with 100-m breaststroke swimming performance, we computed a multiplicative allometric log-linear regression model, which was refined using backward elimination. Results showed that the 100-m breaststroke performance revealed a significant negative association with fat mass and a significant positive association with the segment length ratio (arm ratio = hand length/forearm length) and limb girth ratio (girth ratio = forearm girth/wrist girth). In addition, leg length, biacromial breadth, and biiliocristal breadth revealed significant positive associations with the 100-m breaststroke performance. However, height and body mass did not contribute to the model, suggesting that the advantage of longer levers was limb-specific rather than a general whole-body advantage. In fact, it is only by adopting multiplicative allometric models that the previously mentioned ratios could have been derived. These results highlighted the importance of considering anthropometric characteristics of youth breaststroke swimmers for talent identification and/or athlete monitoring purposes. In addition, these findings may assist orienting swimmers to the appropriate stroke based on their anthropometric characteristics.
An Examination of School Choice and Fifth Grade Science Achievement in Florida
NASA Astrophysics Data System (ADS)
McLarnon, Tara Lynn
Over the past 20 years, a movement to offer greater access and choice in public education has begun to challenge the traditional attendance boundary school system. Public school choice provides an opportunity for parents who do not have the resources to change attendance boundaries but who want additional public school options. Proponents argue that increased competition incentivizes all schools to improve performance. The purpose of this study was to determine whether there were any potential relationships among school choice options and other inputs such as student characteristics when looking at student science achievement. Based on an education production function model, the study focused on the specific output of performance. A conceptual model looking at common inputs related to the outcome of student performance, identified five groups of inputs: school type, student characteristics, learning needs, school characteristics, and teacher quality. Rather than look across states, where policies affecting student performance differ, this study looked exclusively at one large state population. Subjects of the study were fifth grade students in the state of Florida. Utilizing three years of state science assessment data, the roles of school type, selected student demographics, and ELL status were examined using logistic regression and ordinary least squares analysis. Results indicated that, while some subpopulations of students performed better in different school types, school type alone was not a strong predictor of student science achievement.
Sport specificity of mental disorders: the issue of sport psychiatry.
Bär, Karl-Jürgen; Markser, Valentin Z
2013-11-01
The prevalence of psychiatric conditions among elite athletes is still under debate. More and more evidence has accumulated that high-performance athletes are not protected from mental disorders as previously thought. The authors discuss the issue of the sport specificity of selected mental diseases in elite athletes. Specific aspects of eating disorders, exercise addiction, chronic traumatic encephalopathy and mood disorders in the context of overtraining syndrome are examined. In particular, the interrelationship between life and work characteristics unique to elite athletes and the development of mental disorders are reviewed. Differences of clinical presentation and some therapeutic consequences are discussed. The authors suggest that the physical and mental strains endured by elite athletes might influence the onset and severity of their psychiatric disorder. Beside the existing research strategies dealing with the amount of exercise, its intensity and lack of recreation experienced by athletes, further research on psycho-social factors is needed to better understand the sport-specific aetiology of mental disorders in high-performance athletes.
Class-specific Error Bounds for Ensemble Classifiers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prenger, R; Lemmond, T; Varshney, K
2009-10-06
The generalization error, or probability of misclassification, of ensemble classifiers has been shown to be bounded above by a function of the mean correlation between the constituent (i.e., base) classifiers and their average strength. This bound suggests that increasing the strength and/or decreasing the correlation of an ensemble's base classifiers may yield improved performance under the assumption of equal error costs. However, this and other existing bounds do not directly address application spaces in which error costs are inherently unequal. For applications involving binary classification, Receiver Operating Characteristic (ROC) curves, performance curves that explicitly trade off false alarms and missedmore » detections, are often utilized to support decision making. To address performance optimization in this context, we have developed a lower bound for the entire ROC curve that can be expressed in terms of the class-specific strength and correlation of the base classifiers. We present empirical analyses demonstrating the efficacy of these bounds in predicting relative classifier performance. In addition, we specify performance regions of the ROC curve that are naturally delineated by the class-specific strengths of the base classifiers and show that each of these regions can be associated with a unique set of guidelines for performance optimization of binary classifiers within unequal error cost regimes.« less
Yu Xiao; Eric J. Jokela; Tim L. White; Dudley A. Huber
2002-01-01
Differences in foliar N concentrations among species, families, and clones may contribute to variation in relative growth performance under varying environmental conditions. Only limited information exists regarding the importance of genetic vs. environmental controls on the nutritional characteristics of loblolly and slash pine. Knowledge of these processes may...
ERIC Educational Resources Information Center
Huls, Simone
2017-01-01
Nonword repetition (NWR) tasks represent one assessment tool for Specific Language Impairment (SLI). The use of such tasks has been established and verified for monolingual children. However, the diagnostic accuracy of NWR tasks for bilingual children has had variable results and must address several unique characteristics of this population. Gaps…
Theoretical Combustion Performance of Several High-Energy Fuels for Ramjet Engines
NASA Technical Reports Server (NTRS)
Tower, Leonard K; Breitwieser, Roland; Gammon, Benson E
1958-01-01
An analytical evaluation of the air and fuel specific-impulse characteristics of magnesium, magnesium octene-1 slurries, aluminum, aluminum octene-1 slurries, boron, boron octene-1 slurries, carbon, hydrogen, alpha-methylnaphthalene, diborane, pentaborane, and octene-1 is presented. While chemical equilibrium was assumed in the combustion process, the expansion was assumed to occur at fixed composition.
Application of theory to propeller design
NASA Technical Reports Server (NTRS)
Cox, G. G.; Morgan, W. B.
1974-01-01
The various theories concerning propeller design are discussed. The use of digital computers to obtain specific blade shapes to meet appropriate flow conditions is emphasized. The development of lifting-line and lifting surface configurations is analyzed. Ship propulsive performance and basic propeller design considerations are investigated. The characteristics of supercavitating propellers are compared with those of subcavitating propellers.
Grading sugar pine saw logs in trees.
John W. Henley
1972-01-01
Small limbs and small overgrown limbs cause problems when grading saw logs in sugar pine trees. Surface characteristics and lumber recovery information for 426 logs from 64 sugar pine trees were examined. Resulting modifications in the grading specification that allow a grader to ignore small limbs and small limb indicators do not appear to decrease the performance of...
ERIC Educational Resources Information Center
Jordan, Dale R.
This book reviews learning disabilities (LD) in adults and makes suggestions for helping adults cope with these disabilities. Each chapter covers a type of learning disability or related syndrome or explains characteristics of the brain. Chapter 1 explains several types of specific learning disabilities that make classroom performance difficult…
A Factor-Analytic Investigation of Role Types and Profiles of Higher Education Department Chairs.
ERIC Educational Resources Information Center
Carroll, James B.; Gmelch, Walter H.
This paper reports on a study that investigated the role, attitudes, and behaviors of department chairs in higher education. Specifically, the study investigated four objectives: (1) to examine role factors of effective chair performance; (2) to assess the impact of antecedent variables such as individual characteristics (gender, marital status,…
Multi-mission Ni-H2 battery cell for the 1990's
NASA Technical Reports Server (NTRS)
Miller, Lee; Brill, Jack; Dodson, Gary
1989-01-01
A sufficient production, test and operational database is now available to permit design technology optimization for the next decade. The evolved battery cell design features standardized technology intended to support multiple type missions (e.g., both GEO and LEO). Design analyses and validation test cells demonstrate improved performance plus attractive specific-energy characteristics will be achieved.
reflect it. There are commercially available manual and powered suction devices on the market , and several are specifically advertised for use in...combine to suggest that no device on the market meets even the most basic requirements of being small, lightweight, rugged, and demonstrating adequate
2009-07-01
the airspeed for best angle of climb, Vx. c. Determine mission suitability. d. Assess compliance with pertinent Military Specifications and/or...The purpose of this test is to determine the following climb performance characteristics: a. Conditions for best climb angle . b. Conditions... braking velocity. i. Effects of runway condition. j. Approach and landing speeds. k. Landing ground roll distance. l. Limit braking velocity
USDA-ARS?s Scientific Manuscript database
Lateral flow devices (LFD) are commercially available and provide a fast, highly specific, on-site test for avian influenza. Because of the low analytic sensitivity of LFD tests at low virus concentrations, targeted sampling of sick and dead birds has been proposed in order to increase detection pr...
SeaWiFS technical report series. Volume 22: Prelaunch acceptance report for the SeaWFS radiometer
NASA Technical Reports Server (NTRS)
Hooker, Stanford B. (Editor); Firestone, Elaine, R. (Editor); Barnes, Robert A.; Barnes, William L.; Esaias, Wayne E.; Mcclain, Charles R.; Acker, James G. (Editor)
1994-01-01
The final acceptance, or rejection, of the Sea-viewing Wide field-of-view Sensor (SeaWiFS) will be determined by the instrument's on-orbit operation. There is, however, an extensive set of laboratory measurements describing the operating characteristics of the radiometer. Many of the requirements in the Ocean Color Data Mission (OCDM) specifications can be checked only by laboratory measurements. Here, the calibration review panel (composed of the authors of this technical memorandum) examines the laboratory characterization and calibration of SeaWiFS in the light of the OCDM performance specification. Overall, the performance of the SeaWiFS instrument meets or exceeds the requirements of the OCDM contract in all but a few unimportant details. The detailed results of this examination are presented here by following the outline of the specifications, as found in the Contract. The results are presented in the form of requirements and compliance pairs. These results give conclusions on many, but not all, of the performance specifications. The acceptance of this panel of the performance of SeaWiFS must only be considered as an intermediate conclusion. The ultimate acceptance (or rejection) of the SeaWiFS data set will rely on the measurements made by the instrument on orbit.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W.; Tiessen, Alex
Retrocommissioning (RCx) is a systematic process for optimizing energy performance in existing buildings. It specifically focuses on improving the control of energy-using equipment (e.g., heating, ventilation, and air conditioning [HVAC] equipment and lighting) and typically does not involve equipment replacement. Field results have shown proper RCx can achieve energy savings ranging from 5 percent to 20 percent, with a typical payback of two years or less (Thorne 2003). The method presented in this protocol provides direction regarding: (1) how to account for each measure's specific characteristics and (2) how to choose the most appropriate savings verification approach.
NASA Technical Reports Server (NTRS)
Daly, J. K.; Torian, J. G.
1979-01-01
Software design specifications for developing environmental control and life support system (ECLSS) and electrical power system (EPS) programs into interactive computer programs are presented. Specifications for the ECLSS program are at the detail design level with respect to modification of an existing batch mode program. The FORTRAN environmental analysis routines (FEAR) are the subject batch mode program. The characteristics of the FEAR program are included for use in modifying batch mode programs to form interactive programs. The EPS program specifications are at the preliminary design level. Emphasis is on top-down structuring in the development of an interactive program.
Apollo experience report: Television system
NASA Technical Reports Server (NTRS)
Coan, P. P.
1973-01-01
The progress of the Apollo television systems from the early definition of requirements through the development and inflight use of color television hardware is presented. Television systems that have been used during the Apollo Program are discussed, beginning with a description of the specifications for each system. The document describes the technical approach taken for the development of each system and discusses the prototype and engineering hardware built to test the system itself and to perform the testing to verify compatibility with the spacecraft systems. Problems that occurred during the design and development phase are described. Finally, the flight hardware, operational characteristics, and performance during several Apollo missions are described, and specific recommendations for the remaining Apollo flights and future space missions are made.
NASA Technical Reports Server (NTRS)
Cimino, A. A.
1973-01-01
One Thiokol Chemical Corporation TE-M-521-5 solid-propellant apogee rocket motor was successfully fired at an average simulated altitude of about 108,000 ft while spinning at 46 rpm. The general program objectives were to verify compliance of motor performance with the manufacturer's specifications. Specific primary objectives were to determine vacuum ballistic performance of the motor after prefire vibration conditioning and temperature conditioning at 40F, altitude ignition characteristics, motor structural integrity, and motor temperature-time history during and after motor operation. Additional objectives were to measure the lateral (nonaxial) thrust component during motor operation and to measure radiation heat flux in the vicinity of the nozzle exit plane.
Machine learning-based patient specific prompt-gamma dose monitoring in proton therapy
NASA Astrophysics Data System (ADS)
Gueth, P.; Dauvergne, D.; Freud, N.; Létang, J. M.; Ray, C.; Testa, E.; Sarrut, D.
2013-07-01
Online dose monitoring in proton therapy is currently being investigated with prompt-gamma (PG) devices. PG emission was shown to be correlated with dose deposition. This relationship is mostly unknown under real conditions. We propose a machine learning approach based on simulations to create optimized treatment-specific classifiers that detect discrepancies between planned and delivered dose. Simulations were performed with the Monte-Carlo platform Gate/Geant4 for a spot-scanning proton therapy treatment and a PG camera prototype currently under investigation. The method first builds a learning set of perturbed situations corresponding to a range of patient translation. This set is then used to train a combined classifier using distal falloff and registered correlation measures. Classifier performances were evaluated using receiver operating characteristic curves and maximum associated specificity and sensitivity. A leave-one-out study showed that it is possible to detect discrepancies of 5 mm with specificity and sensitivity of 85% whereas using only distal falloff decreases the sensitivity down to 77% on the same data set. The proposed method could help to evaluate performance and to optimize the design of PG monitoring devices. It is generic: other learning sets of deviations, other measures and other types of classifiers could be studied to potentially reach better performance. At the moment, the main limitation lies in the computation time needed to perform the simulations.
NASA Technical Reports Server (NTRS)
Orme, John S.
1995-01-01
The performance seeking control algorithm optimizes total propulsion system performance. This adaptive, model-based optimization algorithm has been successfully flight demonstrated on two engines with differing levels of degradation. Models of the engine, nozzle, and inlet produce reliable, accurate estimates of engine performance. But, because of an observability problem, component levels of degradation cannot be accurately determined. Depending on engine-specific operating characteristics PSC achieves various levels performance improvement. For example, engines with more deterioration typically operate at higher turbine temperatures than less deteriorated engines. Thus when the PSC maximum thrust mode is applied, for example, there will be less temperature margin available to be traded for increasing thrust.
NASA Astrophysics Data System (ADS)
Baker, N. R.; Donakowski, T. D.; Foster, R. B.; Sala, D. L.; Tison, R. R.; Whaley, T. P.; Yudow, B. D.; Swenson, P. F.
1980-01-01
The heat actuated heat pump centered integrated community energy system (HAHP-ICES) is described. The system utilizes a gas fired, engine-driven, heat pump and commercial buildings, and offers several advantages over the more conventional equipment it is intended to supplant. The general nonsite specific application assumes a hypothetical community of one 59,000 cu ft office building and five 24 unit, low rise apartment buildings located in a region with a climate similar to Chicago. Various sensitivity analyses are performed and through which the performance characteristics of the HAHP are explored. The results provided the selection criteria for the site specific application of the HAHP-ICES concept to a real world community. The site-specific community consists of: 42 town houses; five 120 unit, low rise apartment buildings; five 104 unit high rise apartment buildings; one 124,000 cu ft office building; and a single 135,000 cu ft retail building.
A new generation of high performance engines for spacecraft propulsion
NASA Technical Reports Server (NTRS)
Rosenberg, Sanders D.; Schoenman, Leonard
1991-01-01
Experimental data validating advanced engine designs at three thrust levels (5, 15, and 100 lbF) is presented. All of the three engine designs considered employ a Moog bipropellant torque motor valve, platelet injector design, and iridium-lined rhenium combustion chamber. Attention is focused on the performance, robustness, duration, and flexibility characteristics of the engines. It is noted that the 5- and 15-lbF thrust engines can deliver a steady state specific impulse in excess of 310 lbF-sec/lbm at an area ratio of 150:1, while the 150-lbF thrust engines deliver a steady state specific impulse of 320 lbF-sec/lbm at an area ratio of 250:1. The hot-fire test results reveal specific impulse improvements of 15 to 25 sec over conventional fuel film cooled columbium chamber designs while operating at maximum chamber temperatures.
NASA Technical Reports Server (NTRS)
Clark, R. T.; Mccallister, R. D.
1982-01-01
The particular coding option identified as providing the best level of coding gain performance in an LSI-efficient implementation was the optimal constraint length five, rate one-half convolutional code. To determine the specific set of design parameters which optimally matches this decoder to the LSI constraints, a breadboard MCD (maximum-likelihood convolutional decoder) was fabricated and used to generate detailed performance trade-off data. The extensive performance testing data gathered during this design tradeoff study are summarized, and the functional and physical MCD chip characteristics are presented.
Physical evaluation of color and monochrome medical displays using an imaging colorimeter
NASA Astrophysics Data System (ADS)
Roehrig, Hans; Gu, Xiliang; Fan, Jiahua
2013-03-01
This paper presents an approach to physical evaluation of color and monochrome medical grade displays using an imaging colorimeter. The purpose of this study was to examine the influence of medical display types, monochrome or color at the same maximum luminance settings, on diagnostic performance. The focus was on the measurements of physical characteristics including spatial resolution and noise performance, which we believed could affect the clinical performance. Specifically, Modulation Transfer Function (MTF) and Noise Power Spectrum (NPS) were evaluated and compared at different digital driving levels (DDL) between two EIZO displays.
DOE Office of Scientific and Technical Information (OSTI.GOV)
King, D.L.
1995-11-01
The objective of this work was to develop improved performance model for modules and systems for for all operating conditions for use in module specifications, system and BOS component design, and system rating or monitoring. The approach taken was to identify and quantify the influence of dominant factors of solar irradiance, cell temperature, angle-of-incidence; and solar spectrum; use outdoor test procedures to separate the effects of electrical, thermal, and optical performance; use fundamental cell characteristics to improve analysis; and combine factors in simple model using the common variables.
Alternate aircraft fuels prospects and operational implications
NASA Technical Reports Server (NTRS)
Witcofski, R. D.
1977-01-01
The paper discusses NASA studies of the potentials of coal-derived aviation fuels, specifically synthetic aviation kerosene, liquid methane, and liquid hydrogen. Topics include areas of fuel production, air terminal requirements for aircraft fueling (for liquid hydrogen only), and the performance characteristics of aircraft designed to utilize alternate fuels. Energy requirements associated with the production of each of the three selected fuels are determined, and fuel prices are estimated. Subsonic commercial air transports using liquid hydrogen fuel have been analyzed, and their performance and the performance of aircraft which use commercial aviation kerosene are compared. Environmental and safety issues are considered.
Inter-institutional Variation in Use of Caesarean Delivery for Labour Dystocia.
Riddell, Corinne A; Hutcheon, Jennifer A; Strumpf, Erin C; Abenhaim, Haim A; Kaufman, Jay S
2017-11-01
To establish the degree of variation across hospitals in the use of Caesarean delivery for the indication of labour dystocia before and after accounting for maternal, fetal, and hospital characteristics. This study was a retrospective, population-based cohort study of nulliparous women delivering term singletons in cephalic position following labour. Delivery visits were extracted from three provincial perinatal registries in the Canadian provinces of Ontario, Alberta, and British Columbia, from 2008-2012. Crude hospital-specific rates of Caesarean delivery for labour dystocia were reported, and these rates were then stabilized to account for hospitals with low delivery volumes. Rates were then adjusted for maternal, fetal, and hospital characteristics using hierarchical logistic regression. Among 403 205 women delivering at 170 hospitals, the overall Caesarean delivery rate was 21.0%, and the rate of Caesarean delivery for labour dystocia was 12.7%, indicating that 60% of all Caesarean deliveries were performed in part for this indication. The middle 95% of hospitals had Caesarean delivery rates for labour dystocia ranging from 4.5% to 24.7%. Differences in maternal case mix and hospital characteristics explained only a small proportion of this variation (95% central range 6.3%-21.7%). Considerable inter-hospital variation in rates of Caesarean delivery for labour dystocia remained after accounting for differences in maternal and hospital factors. Reporting systems that monitor variation in inter-institutional rates should incorporate stabilization and adjustment for case-mix differences and consider indication-specific rates of Caesarean delivery to more fairly compare hospital performance and better target interventions to reduce Caesarean delivery for specific indications. Copyright © 2017 The Society of Obstetricians and Gynaecologists of Canada/La Société des obstétriciens et gynécologues du Canada. Published by Elsevier Inc. All rights reserved.
ANTHROPOMETRIC CHARACTERISTICS AND FUNCTIONAL CAPACITY OF ELITE ROWERS AND HANDBALL PLAYERS.
Karaba Jakovljevic, Dea; Jovanovic, Gordana; Eric, Mirela; Klasnja, Aleksandar; Slavic, Danijel; Lukac, Damir
2016-09-01
Anthropometric and anaerobic profile of elite athletes are fundamental for the assessment of their respective performance. The present study was designed to evaluate the anthro- pornetric parameters, body composition and anaerobic characteristics of elite male handball players and rowers, and to compare them in relation to specific sport demands. The study group consisted of 41 elite national level athletes: 20 handball players (aged 23.7±3.72) and 21 rowers (aged 19.7±2.84). Anthropometric characteristics (body mass, body height, skinfold thickness, body circumferences), and body fat mass were evaluated, and Wingate anaerobic test for anaerobic power assessment Iwas applied. The significant differences were noted in chest-upper arm, waist and hip circumferences, and supraspinal and calf skinfolds between the two investigated groups. Rowers showed higher values of fat body mass (13.2±3.76 vs. 10.7±3.76%), but lower body mass index (22.0±1,92 vs. 25.7?2.31 kg/in12) compared to handball players. When analyzing the Wingate test parameters, significantly higher values of absolute anaerobic power (786±127 vs. 691±140 W), absolute explosive power in the handball players compared to the rowers were recorded ( 18±26.3 vs. 105±27.8 W/s), whi le rowers achieved higher relative anaerobic capacity (192±3 1.2 vs. 177±E20.8 J/ kg). Specific body composition and anthropometri- cal assessment as a part of morphological analysis should complement physiological profile of elite athletes. The analysis of the anaerobic performance shows that the handball players have greater alactic anaerobic and explosive power component, compared to the rowers in whom the anaerobic endurance and specific training have the greatest effect on the consumption of dominant metabolic substrate during the race.
Yo, Chia-Hung; Lee, Si-Huei; Chang, Shy-Shin; Lee, Matthew Chien-Hung; Lee, Chien-Chang
2014-02-20
We performed a systematic review and meta-analysis of studies on high-sensitivity C-reactive protein (hs-CRP) assays to see whether these tests are predictive of atrial fibrillation (AF) recurrence after cardioversion. Systematic review and meta-analysis. PubMed, EMBASE and Cochrane databases as well as a hand search of the reference lists in the retrieved articles from inception to December 2013. This review selected observational studies in which the measurements of serum CRP were used to predict AF recurrence. An hs-CRP assay was defined as any CRP test capable of measuring serum CRP to below 0.6 mg/dL. We summarised test performance characteristics with the use of forest plots, hierarchical summary receiver operating characteristic curves and bivariate random effects models. Meta-regression analysis was performed to explore the source of heterogeneity. We included nine qualifying studies comprising a total of 347 patients with AF recurrence and 335 controls. A CRP level higher than the optimal cut-off point was an independent predictor of AF recurrence after cardioversion (summary adjusted OR: 3.33; 95% CI 2.10 to 5.28). The estimated pooled sensitivity and specificity for hs-CRP was 71.0% (95% CI 63% to 78%) and 72.0% (61% to 81%), respectively. Most studies used a CRP cut-off point of 1.9 mg/L to predict long-term AF recurrence (77% sensitivity, 65% specificity), and 3 mg/L to predict short-term AF recurrence (73% sensitivity, 71% specificity). hs-CRP assays are moderately accurate in predicting AF recurrence after successful cardioversion.
Correlates of State Enactment of Elementary School Physical Education Laws
Monnat, Shannon M.; Lounsbery, Monica A.F.; Smith, Nicole J.
2014-01-01
Objective To describe variation in U.S. state elementary school physical education (PE) policies and to assess associations between state PE policy enactment and education funding, academic achievement, sociodemographic disadvantage, and political characteristics. Methods U.S. state laws regarding school PE time, staffing, curriculum, fitness assessment, and moderate-to-vigorous physical activity (MVPA) in 2012 were classified as strong/specific, weak/nonspecific, or none based on codified law ratings within the Classification of Laws Associated with School Students (C.L.A.S.S.). Laws were merged with state-level data from multiple sources. Logistic regression was used to determine associations between state characteristics and PE laws (N=51). Results Laws with specific PE and MVPA time requirements and evidence-based curriculum standards were more likely in states with low academic performance and in states with sociodemographically disadvantaged populations. School day length was positively associated with enacting a PE curriculum that referenced evidence-based standards. School funding and political characteristics were not associated with PE laws. Conclusions Limited time and high-stakes testing requirements force schools to prioritize academic programs, posing barriers to state passage of specific PE laws. To facilitate PE policy enactment, it may be necessary to provide evidence of how PE policies can be implemented within existing time and staffing structures. PMID:25230368
Correlates of state enactment of elementary school physical education laws.
Monnat, Shannon M; Lounsbery, Monica A F; Smith, Nicole J
2014-12-01
To describe variation in U.S. state elementary school physical education (PE) policies and to assess associations between state PE policy enactment and education funding, academic achievement, sociodemographic disadvantage, and political characteristics. U.S. state laws regarding school PE time, staffing, curriculum, fitness assessment, and moderate-to-vigorous physical activity (MVPA) in 2012 were classified as strong/specific, weak/nonspecific, or none based on codified law ratings within the Classification of Laws Associated with School Students (C.L.A.S.S.). Laws were merged with state-level data from multiple sources. Logistic regression was used to determine associations between state characteristics and PE laws (N=51). Laws with specific PE and MVPA time requirements and evidence-based curriculum standards were more likely in states with low academic performance and in states with sociodemographically disadvantaged populations. School day length was positively associated with enacting a PE curriculum that referenced evidence-based standards. School funding and political characteristics were not associated with PE laws. Limited time and high-stake testing requirements force schools to prioritize academic programs, posing barriers to state passage of specific PE laws. To facilitate PE policy enactment, it may be necessary to provide evidence on how PE policies can be implemented within existing time and staffing structures. Copyright © 2014 Elsevier Inc. All rights reserved.
School and Behavioral Outcomes Among Inner City Children: Five-Year Follow-Up.
Kim, Seijeoung; Mazza, Jessica; Zwanziger, Jack; Henry, David
2014-10-01
Educational achievement is a key determinant of future life chances, but children growing up in poverty tend to do worse by many academic measures. Family, school, and neighborhood contextual characteristics may affect academic outcomes. In an attempt to explore neighborhood and individual level factors, we performed multilevel analyses to explain child's behavioral problems, repeat grade, average math and reading scores. Outcome measures were associated with specific neighborhood characteristics, above and beyond the effect of student/family level factors. The findings warrant further consideration of ecological interventions aiming to improve academic and behavioral outcomes of children living in poverty.
Experimental Characterization of Aluminum-Based Hybrid Composites Obtained Through Powder Metallurgy
NASA Astrophysics Data System (ADS)
Marcu, D. F.; Buzatu, M.; Ghica, V. G.; Petrescu, M. I.; Popescu, G.; Niculescu, F.; Iacob, G.
2018-06-01
The paper presents some experimental results concerning fabrication through powder metallurgy (P/M) of aluminum-based hybrid composites - Al/Al2O3/Gr. In order to understand the mechanisms that occur during the P/M processes of obtaining Al/Al2O3/Gr composite, we correlated the physical characteristics with their micro-structural characteristics. The characterization was performed using analysis techniques specific for P/M process, SEM-EDS and XRD analyses. Micro-structural characterization of the composites has revealed fairly uniform distribution this resulting in good properties of the final composite material.
NASA Technical Reports Server (NTRS)
Ivancic, William D.
1998-01-01
Various issues associated with satellite/terrestrial end-to-end communication interoperability are presented in viewgraph form. Specific topics include: 1) Quality of service; 2) ATM performance characteristics; 3) MPEG-2 transport stream mapping to AAL-5; 4) Observation and discussion of compressed video tests over ATM; 5) Digital video over satellites status; 6) Satellite link configurations; 7) MPEG-2 over ATM with binomial errors; 8) MPEG-2 over ATM channel characteristics; 8) MPEG-2 over ATM over emulated satellites; 9) MPEG-2 transport stream with errors; and a 10) Dual decoder test.
Handbook of satellite pointing errors and their statistical treatment
NASA Astrophysics Data System (ADS)
Weinberger, M. C.
1980-03-01
This handbook aims to provide both satellite payload and attitude control system designers with a consistent, unambiguous approach to the formulation, definition and interpretation of attitude pointing and measurement specifications. It reviews and assesses the current terminology and practices, and from them establishes a set of unified terminology, giving the user a sound basis to understand the meaning and implications of various specifications and requirements. Guidelines are presented for defining the characteristics of the error sources influencing satellite pointing and attitude measurement, and their combination in performance verification.
A theoretical model to determine the capacity performance of shape-specific electrodes
NASA Astrophysics Data System (ADS)
Yue, Yuan; Liang, Hong
2018-06-01
A theory is proposed to explain and predict the electrochemical process during reaction between lithium ions and electrode materials. In the model, the process of reaction is proceeded into two steps, surface adsorption and diffusion of lithium ions. The surface adsorption is an instantaneous process for lithium ions to adsorb onto the surface sites of active materials. The diffusion of lithium ions into particles is determined by the charge-discharge condition. A formula to determine the maximum specific capacity of active materials at different charging rates (C-rates) is derived. The maximum specific capacity is correlated to characteristic parameters of materials and cycling - such as size, aspect ratio, surface area, and C-rate. Analysis indicates that larger particle size or greater aspect ratio of active materials and faster C-rates can reduce maximum specific capacity. This suggests that reducing particle size of active materials and slowing the charge-discharge speed can provide enhanced electrochemical performance of a battery cell. Furthermore, the model is validated by published experimental results. This model brings new understanding in quantification of electrochemical kinetics and capacity performance. It enables development of design strategies for novel electrodes and future generation of energy storage devices.
Space Storable Rocket Technology (SSRT) basic program
NASA Technical Reports Server (NTRS)
Chazen, M. L.; Mueller, T.; Casillas, A. R.; Huang, D.
1992-01-01
The Space Storable Rocket Technology Program (SSRT) was conducted to establish a technology for a new class of high performance and long life bipropellant engines using space storable propellants. The results are described. Task 1 evaluated several characteristics for a number of fuels to determine the best space storable fuel for use with LO2. The results indicated that LO2-N2H4 is the best propellant combination and provides the maximum mission/system capability maximum payload into GEO of satellites. Task 2 developed two models, performance and thermal. The performance model indicated the performance goal of specific impulse greater than or = 340 seconds (sigma = 204) could be achieved. The thermal model was developed and anchored to hot fire test data. Task 3 consisted of design, fabrication, and testing of a 200 lbf thrust test engine operating at a chamber pressure of 200 psia using LO2-N2H4. A total of 76 hot fire tests were conducted demonstrating performance greater than 340 (sigma = 204) which is a 25 second specific impulse improvement over the existing highest performance flight apogee type engines.
García Vicente, Ana María; Delgado-Bolton, Roberto C; Amo-Salas, Mariano; López-Fidalgo, Jesús; Caresia Aróztegui, Ana Paula; García Garzón, José Ramón; Orcajo Rincón, Javier; García Velloso, María José; de Arcocha Torres, María; Alvárez Ruíz, Soledad
2017-08-01
The detection of occult cancer in patients suspected of having a paraneoplastic neurological syndrome (PNS) poses a diagnostic challenge. The aim of our study was to perform a systematic review and meta-analysis to assess the diagnostic performance of FDG PET for the detection of occult malignant disease responsible for PNS. A systematic review of the literature (MEDLINE, EMBASE, Cochrane, and DARE) was undertaken to identify studies published in any language. The search strategy was structured after addressing clinical questions regarding the validity or usefulness of the test, following the PICO framework. Inclusion criteria were studies involving patients with PNS in whom FDG PET was performed to detect malignancy, and which reported sufficient primary data to allow calculation of diagnostic accuracy parameters. When possible, a meta-analysis was performed to calculate the joint sensitivity, specificity, and detection rate for malignancy (with 95% confidence intervals [CIs]), as well as a subgroup analysis based on patient characteristics (antibodies, syndrome). The comprehensive literature search revealed 700 references. Sixteen studies met the inclusion criteria and were ultimately selected. Most of the studies were retrospective (12/16). For the quality assessment, the QUADAS-2 tool was applied to assess the risk of bias. Across 16 studies (793 patients), the joint sensitivity, specificity, and detection rate for malignancy with FDG PET were 0.87 (95% CI: 0.80-0.93), 0.86 (95% CI: 0.83-0.89), and 14.9% (95% CI: 11.5-18.7), respectively. The area under the curve (AUC) of the summary ROC curve was 0.917. Homogeneity of results was observed for sensitivity but not for specificity. Some of the individual studies showed large 95% CIs as a result of small sample size. The results of our meta-analysis reveal high diagnostic performance of FDG PET in the detection of malignancy responsible for PNS, not affected by the presence of onconeural antibodies or clinical characteristics.
A novel data-driven learning method for radar target detection in nonstationary environments
Akcakaya, Murat; Nehorai, Arye; Sen, Satyabrata
2016-04-12
Most existing radar algorithms are developed under the assumption that the environment (clutter) is stationary. However, in practice, the characteristics of the clutter can vary enormously depending on the radar-operational scenarios. If unaccounted for, these nonstationary variabilities may drastically hinder the radar performance. Therefore, to overcome such shortcomings, we develop a data-driven method for target detection in nonstationary environments. In this method, the radar dynamically detects changes in the environment and adapts to these changes by learning the new statistical characteristics of the environment and by intelligibly updating its statistical detection algorithm. Specifically, we employ drift detection algorithms to detectmore » changes in the environment; incremental learning, particularly learning under concept drift algorithms, to learn the new statistical characteristics of the environment from the new radar data that become available in batches over a period of time. The newly learned environment characteristics are then integrated in the detection algorithm. Furthermore, we use Monte Carlo simulations to demonstrate that the developed method provides a significant improvement in the detection performance compared with detection techniques that are not aware of the environmental changes.« less
The Effect of the MassHealth Hospital Pay-for-Performance Program on Quality
Ryan, Andrew M; Blustein, Jan
2011-01-01
Objective To test the effect of Massachusetts Medicaid's (MassHealth) hospital-based pay-for-performance (P4P) program, implemented in 2008, on quality of care for pneumonia and surgical infection prevention (SIP). Data Hospital Compare process of care quality data from 2004 to 2009 for acute care hospitals in Massachusetts (N = 62) and other states (N = 3,676) and American Hospital Association data on hospital characteristics from 2005. Study Design Panel data models with hospital fixed effects and hospital-specific trends are estimated to test the effect of P4P on composite quality for pneumonia and SIP. This base model is extended to control for the completeness of measure reporting. Further sensitivity checks include estimation with propensity-score matched control hospitals, excluding hospitals in other P4P programs, varying the time period during which the program was assumed to have an effect, and testing the program effect across hospital characteristics. Principal Findings Estimates from our preferred specification, including hospital fixed effects, trends, and the control for measure completeness, indicate small and nonsignificant program effects for pneumonia (−0.67 percentage points, p>.10) and SIP (−0.12 percentage points, p>.10). Sensitivity checks indicate a similar pattern of findings across specifications. Conclusions Despite offering substantial financial incentives, the MassHealth P4P program did not improve quality in the first years of implementation. PMID:21210796
Physical characteristics that predict involvement with the ball in recreational youth soccer.
Ré, Alessandro H Nicolai; Cattuzzo, Maria Teresa; Henrique, Rafael Dos Santos; Stodden, David F
2016-09-01
This study examined the relative contribution of age, stage of puberty, anthropometric characteristics, health-related fitness, soccer-specific tests and match-related technical performance to variance in involvements with the ball during recreational 5-a-side small-sided (32 × 15 m) soccer matches. Using a cross-sectional design, 80 healthy male students (14.6 ± 0.5 years of age; range 13.6-15.4) who played soccer recreationally were randomly divided into 10 teams and played against each other. Measurements included height, body mass, pubertal status, health-related fitness (12-min walk/run test, standing long jump, 15-m sprint and sit-ups in 30 s), soccer-specific tests (kicking for speed, passing for accuracy and agility run with and without a ball), match-related technical performance (kicks, passes and dribbles) and involvements with the ball during matches. Forward multiple regression analysis revealed that cardiorespiratory fitness (12-min walk/run test) accounted for 36% of the variance in involvements with the ball. When agility with the ball (zigzag running) and power (standing long jump) were included among the predictors, the total explained variance increased to 62%. In conclusion, recreational adolescent players, regardless of their soccer-specific skills, may increase participation in soccer matches most through physical activities that promote improvement in cardiorespiratory fitness, muscle power and agility.
Eletrobras management program in ergonomics: the pursuit of excellence through maturity levels.
Pires, Paulo Roberto de Oliveira Bassil; Rezende, Fagner Fagundes
2012-01-01
Ergonomics for Eletrobras arose from the need in having an environment more suitable to the characteristics and circumstances of employees, in compliance with Regulation Standard no. 17 - Ergonomics (NR17) of the Ministry of Labor and Employment. Being a mixed economy company with regionalized anthropometric characteristics of its employees, the study of ergonomic adjustments and improvement of the concept of Ergonomics were and have been of great importance to the company's production environment. These advances have contributed to the development of specific technical criteria for the purchase of furniture and work tools (accessories), apart from their possible effects on the user. Ergonomics has been perceived as a technical-scientific tool, aimed to study labor interactions, new technologies and specific characteristics of the activities performed. To meet these demands a multidisciplinary Ergonomics Committee was created in Eletrobras, and effectively established the Ergonomics Management Program in the company; This program is marked by well-defined phases with great success in making use of these studies for other types of corporate activities and also facilitating the program control and its maturity levels, even at a business level.
2011-01-01
Background Innovation through an open source model has proven to be successful for software development. This success has led many to speculate if open source can be applied to other industries with similar success. We attempt to provide an understanding of open source software development characteristics for researchers, business leaders and government officials who may be interested in utilizing open source innovation in other contexts and with an emphasis on drug discovery. Methods A systematic review was performed by searching relevant, multidisciplinary databases to extract empirical research regarding the common characteristics and barriers of initiating and maintaining an open source software development project. Results Common characteristics to open source software development pertinent to open source drug discovery were extracted. The characteristics were then grouped into the areas of participant attraction, management of volunteers, control mechanisms, legal framework and physical constraints. Lastly, their applicability to drug discovery was examined. Conclusions We believe that the open source model is viable for drug discovery, although it is unlikely that it will exactly follow the form used in software development. Hybrids will likely develop that suit the unique characteristics of drug discovery. We suggest potential motivations for organizations to join an open source drug discovery project. We also examine specific differences between software and medicines, specifically how the need for laboratories and physical goods will impact the model as well as the effect of patents. PMID:21955914
Cighetti, Giuliana; Bamonti, Fabrizia; Aman, Caroline S; Gregori, Dario; De Giuseppe, Rachele; Novembrino, Cristina; de Liso, Federica; Maiavacca, Rita; Paroni, Rita
2015-01-01
To test the performance of different analytical approaches in highlighting the occurrence of deregulated redox status in various physio-pathological situations. 35 light and 61 heavy smokers, 19 chronic renal failure, 59 kidney transplanted patients, and 87 healthy controls were retrospectively considered for the study. Serum oxidative stress and antioxidant status, assessed by spectrophotometric Reactive Oxygen Metabolites (d-ROMs) and Total Antioxidant Capacity (TAC) tests, respectively, were compared with plasma free (F-MDA) and total (T-MDA) malondialdehyde, both quantified by isotope-dilution-gas chromatography-mass spectrometry (ID-GC-MS). Sensitivity, specificity and cut-off points of T-MDA, F-MDA, d-ROMs and TAC were evaluated by both Receiver Operating Characteristic (ROC) analyses and area under the ROC curve (AUC). Only T-MDA assay showed a clear absence of oxidative stress in controls and significant increase in all patients (AUC 1.00, sensitivity and specificity 100%). Accuracy was good for d-ROMs (AUC 0.87, sensitivity 72.8%, specificity 100%) and F-MDA (AUC 0.82, sensitivity 74.7%, specificity 83.9%), but not high enough for TAC to show in patients impaired antioxidant defense (AUC 0.66, sensitivity 52.0%, specificity 92.9%). This study reveals T-MDA as the best marker to detect oxidative stress, shows the ability of d-ROMs to identify modified oxidative status particularly in the presence of high damages, and evidences the poor TAC performance. d-ROMs and TAC assays could be useful for routine purposes; however, for an accurate clinical data evaluation, their comparison versus a "gold standard method" is required. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Grading technologies for the manufacture of innovative cutting blades
NASA Astrophysics Data System (ADS)
Rostek, Tim; Homberg, Werner
2018-05-01
Cutting blades for harvesting applications are used in a variety of agricultural machines. These parts are in contact with highly abrasive lawn clippings and often wear out within hours which results in high expensive re-sharpening maintenance. This paper relates to manufacturing techniques enhancing the durability of cutting blades based on a structural analysis of the prevailing wear mechanisms containing chipping and abrasive wear. Each mechanism results in specific demands on the cutting edge's mechanical characteristics. The design of evaluation methods respectively is one issue of the paper. This is basis for approaches to improve the cutting edge performance on purpose. On option to improve abrasive wear resistance and, thus, service life is the application of locally graded steel materials as semi-finished products for self-sharpening cutting blades. These materials comprise a layered structure consisting of a hard, wear resistant layer and a relatively softer layer which is lesser wear resistant. As the cutting blade is subjected to wear conditions, the less wear resistant layer wears faster than the relatively more wear resistant harder layer revealing a durable cross section of the cutting edge and, thus, cutting performance. Anyways, chipping is another key issue on the cutting edge's lifetime. Here, the cutting edges cross section by means of geometry and grind respectively as well as its mechanical properties matter. FEM analysis reveal innovative options to optimize the cross section of the blade as well as thermomechanical strengthening add further strength to reduce chipping. This paper contains a comprehensive strategy to improve cutting blades with use of innovative manufacturing technologies which apply application-specific graded mechanical characteristics and, thus, significantly improved performance characteristics.
Berlin, Conny; Blanch, Carles; Lewis, David J; Maladorno, Dionigi D; Michel, Christiane; Petrin, Michael; Sarp, Severine; Close, Philippe
2012-06-01
The detection of safety signals with medicines is an essential activity to protect public health. Despite widespread acceptance, it is unclear whether recently applied statistical algorithms provide enhanced performance characteristics when compared with traditional systems. Novartis has adopted a novel system for automated signal detection on the basis of disproportionality methods within a safety data mining application (Empirica™ Signal System [ESS]). ESS uses two algorithms for routine analyses: empirical Bayes Multi-item Gamma Poisson Shrinker and logistic regression (LR). A model was developed comprising 14 medicines, categorized as "new" or "established." A standard was prepared on the basis of safety findings selected from traditional sources. ESS results were compared with the standard to calculate the positive predictive value (PPV), specificity, and sensitivity. PPVs of the lower one-sided 5% and 0.05% confidence limits of the Bayes geometric mean (EB05) and of the LR odds ratio (LR0005) almost coincided for all the drug-event combinations studied. There was no obvious difference comparing the PPV of the leading Medical Dictionary for Regulatory Activities (MedDRA) terms to the PPV for all terms. The PPV of narrow MedDRA query searches was higher than that for broad searches. The widely used threshold value of EB05 = 2.0 or LR0005 = 2.0 together with more than three spontaneous reports of the drug-event combination produced balanced results for PPV, sensitivity, and specificity. Consequently, performance characteristics were best for leading terms with narrow MedDRA query searches irrespective of applying Multi-item Gamma Poisson Shrinker or LR at a threshold value of 2.0. This research formed the basis for the configuration of ESS for signal detection at Novartis. Copyright © 2011 John Wiley & Sons, Ltd.
Roy, Jean-Sébastien; Braën, Caroline; Leblond, Jean; Desmeules, François; Dionne, Clermont E; MacDermid, Joy C; Bureau, Nathalie J; Frémont, Pierre
2015-01-01
Background Different diagnostic imaging modalities, such as ultrasonography (US), MRI, MR arthrography (MRA) are commonly used for the characterisation of rotator cuff (RC) disorders. Since the most recent systematic reviews on medical imaging, multiple diagnostic studies have been published, most using more advanced technological characteristics. The first objective was to perform a meta-analysis on the diagnostic accuracy of medical imaging for characterisation of RC disorders. Since US is used at the point of care in environments such as sports medicine, a secondary analysis assessed accuracy by radiologists and non-radiologists. Methods A systematic search in three databases was conducted. Two raters performed data extraction and evaluation of risk of bias independently, and agreement was achieved by consensus. Hierarchical summary receiver-operating characteristic package was used to calculate pooled estimates of included diagnostic studies. Results Diagnostic accuracy of US, MRI and MRA in the characterisation of full-thickness RC tears was high with overall estimates of sensitivity and specificity over 0.90. As for partial RC tears and tendinopathy, overall estimates of specificity were also high (>0.90), while sensitivity was lower (0.67–0.83). Diagnostic accuracy of US was similar whether a trained radiologist, sonographer or orthopaedist performed it. Conclusions Our results show the diagnostic accuracy of US, MRI and MRA in the characterisation of full-thickness RC tears. Since full thickness tear constitutes a key consideration for surgical repair, this is an important characteristic when selecting an imaging modality for RC disorder. When considering accuracy, cost, and safety, US is the best option. PMID:25677796
[Selection criteria of mobile lifters in the hospital setting].
Ferriero, G; Ottonello, M; Franchignoni, F
2002-01-01
The manual handling of patients with limited mobility represents the major cause of musculoskeletal injury to the spine in paramedical health care workers. Within the hospital, the more complex procedures of patient transfer often require the use of mobile hoists. The aim of this paper is to describe the basic criteria for the selection of such hoists. The main characteristics of a hoist are its stability, the sling attachment, the speed of operation, range of movement of the spreader bar, safety of the operation being performed, patient comfort, the physical effort required on the part of the health care worker, manoeuvrability and simplicity of use. Important organizational-structural features to evaluate include: the type of patient normally present in the unit concerned, the specific movement to be performed, the structural characteristics of the environment, and the work organization of the personnel.
Gilhuley, Kathleen; Cianciminio-Bordelon, Diane; Tang, Yi-Wei
2012-01-01
We compared the performance characteristics of culture and the Cepheid Xpert vanA assay for routine surveillance of vancomycin-resistant enterococci (VRE) from rectal swabs in patients at high risk for VRE carriage. The Cepheid Xpert vanA assay had a limit of detection of 100 CFU/ml and correctly detected 101 well-characterized clinical VRE isolates with no cross-reactivity in 27 non-VRE and related culture isolates. The clinical sensitivity, specificity, positive predictive value, and negative predictive value of the Xpert vanA PCR assay were 100%, 96.9%, 91.3%, and 100%, respectively, when tested on 300 consecutively collected rectal swabs. This assay provides excellent predictive values for prompt identification of VRE-colonized patients in hospitals with relatively high rates of VRE carriage. PMID:22972822
Performance of Distributed CFAR Processors in Pearson Distributed Clutter
NASA Astrophysics Data System (ADS)
Messali, Zoubeida; Soltani, Faouzi
2006-12-01
This paper deals with the distributed constant false alarm rate (CFAR) radar detection of targets embedded in heavy-tailed Pearson distributed clutter. In particular, we extend the results obtained for the cell averaging (CA), order statistics (OS), and censored mean level CMLD CFAR processors operating in positive alpha-stable (P&S) random variables to more general situations, specifically to the presence of interfering targets and distributed CFAR detectors. The receiver operating characteristics of the greatest of (GO) and the smallest of (SO) CFAR processors are also determined. The performance characteristics of distributed systems are presented and compared in both homogeneous and in presence of interfering targets. We demonstrate, via simulation results, that the distributed systems when the clutter is modelled as positive alpha-stable distribution offer robustness properties against multiple target situations especially when using the "OR" fusion rule.
Conductor gestures influence evaluations of ensemble performance
Morrison, Steven J.; Price, Harry E.; Smedley, Eric M.; Meals, Cory D.
2014-01-01
Previous research has found that listener evaluations of ensemble performances vary depending on the expressivity of the conductor’s gestures, even when performances are otherwise identical. It was the purpose of the present study to test whether this effect of visual information was evident in the evaluation of specific aspects of ensemble performance: articulation and dynamics. We constructed a set of 32 music performances that combined auditory and visual information and were designed to feature a high degree of contrast along one of two target characteristics: articulation and dynamics. We paired each of four music excerpts recorded by a chamber ensemble in both a high- and low-contrast condition with video of four conductors demonstrating high- and low-contrast gesture specifically appropriate to either articulation or dynamics. Using one of two equivalent test forms, college music majors and non-majors (N = 285) viewed sixteen 30 s performances and evaluated the quality of the ensemble’s articulation, dynamics, technique, and tempo along with overall expressivity. Results showed significantly higher evaluations for performances featuring high rather than low conducting expressivity regardless of the ensemble’s performance quality. Evaluations for both articulation and dynamics were strongly and positively correlated with evaluations of overall ensemble expressivity. PMID:25104944
Kim, Jeong Rye; Suh, Chong Hyun; Yoon, Hee Mang; Lee, Jin Seong; Cho, Young Ah; Jung, Ah Young
2018-03-01
To assess the diagnostic performance of shear-wave elastography for determining the severity of liver fibrosis in children and adolescents. An electronic literature search of PubMed and EMBASE was conducted. Bivariate modelling and hierarchical summary receiver-operating-characteristic modelling were performed to evaluate the diagnostic performance of shear-wave elastography. Meta-regression and subgroup analyses according to the modality of shear-wave imaging and the degree of liver fibrosis were also performed. Twelve eligible studies with 550 patients were included. Shear-wave elastography showed a summary sensitivity of 81 % (95 % CI: 71-88) and a specificity of 91 % (95 % CI: 83-96) for the prediction of significant liver fibrosis. The number of measurements of shear-wave elastography performed was a significant factor influencing study heterogeneity. Subgroup analysis revealed shear-wave elastography to have an excellent diagnostic performance according to each degree of liver fibrosis. Supersonic shear imaging (SSI) had a higher sensitivity (p<.01) and specificity (p<.01) than acoustic radiation force impulse imaging (ARFI). Shear-wave elastography is an excellent modality for the evaluation of the severity of liver fibrosis in children and adolescents. Compared with ARFI, SSI showed better diagnostic performance for prediction of significant liver fibrosis. • Shear-wave elastography is beneficial for determining liver fibrosis severity in children. • Shear-wave elastography showed summary sensitivity of 81 %, specificity of 91 %. • SSI showed better diagnostic performance than ARFI for significant liver fibrosis.
NASA Astrophysics Data System (ADS)
Suda, Yoshiyuki; Mizutani, Akitaka; Harigai, Toru; Takikawa, Hirofumi; Ue, Hitoshi; Umeda, Yoshito
2017-01-01
We fabricated electric double layer capacitors (EDLCs) using particulate and fibrous types of carbon nanomaterials with a wide range of specific surface areas and resistivity as an active material. The carbon nanomaterials used in this study are carbon nanoballoons (CNBs), onion-like carbon (OLC), and carbon nanocoils (CNCs). A commercially used activated carbon (AC) combined with a conductive agent was used as a comparison. We compared the EDLC performance using cyclic voltammetry (CV), galvanostatic charge/discharge testing, and electrochemical impedance spectroscopy (EIS). OLC showed a poor EDLC performance, although it has the lowest resistivity among the carbon nanomaterials. CNB, which has a 1/16 lower specific surface area than AC but higher specific surface area than CNC and OLC, had a higher specific capacitance than CNC and OLC. Moreover, at current densities of 1.5 Ag-1 and larger, the specific capacitance of the EDLC using CNB was almost the same as that using AC. Electrochemical impedance spectroscopy of the EDLCs revealed that the CNB and CNC electrodes had a much lower internal resistance than the AC electrode, which correlated with a low capacitance maintenance factor as the current density increased.
NASA Astrophysics Data System (ADS)
Wu, Feng-Chin; Tseng, Ru-Ling; Hu, Chi-Chang; Wang, Chen-Ching
Four kinds of activated carbons (denoted as ACs) with specific surface area of ca. 1050 m 2 g -1 were fabricated from fir wood and pistachio shell by means of steam activation or chemical activation with KOH. Pore structures of ACs were characterized by a t-plot method based on N 2 adsorption isotherms. The amount of mesopores within KOH-activated carbons ranged from 9.2 to 15.3% while 33.3-49.5% of mesopores were obtained for the steam-activated carbons. The pore structure, surface functional groups, and raw materials of ACs, as well as pH and the supporting electrolyte were also found to be significant factors determining the capacitive characteristics of ACs. The excellent capacitive characteristics in both acidic and neutral media and the weak dependence of the specific capacitance on the scan rate of cyclic voltammetry (CV) for the ACs derived from the pistachio shell with steam activation (denoted as P-H 2O-AC) revealed their promising potential in the application of supercapacitors. The ACs derived from fir wood with KOH activation (denoted as F-KOH-AC), on the other hand, showed the best capacitive performance in H 2SO 4 due to excellent reversibility and high specific capacitance (180 F g -1 measured at 10 mV s -1), which is obviously larger than 100 F g -1 (a typical value of activated carbons with specific surface areas equal to/above 1000 m 2 g -1).
1973-05-01
dry density of total sample Yf = dry unit weight of finer fraction G = bulk specific gravity of coarser fraction (based on ovendry weightq). Same as G...ttl~o o 40 oe o Fig. ii. Theoretical and experimental densities of eclayey sandy gravel (GC) DeGray meterial expressions require tests performed on
Revision of ISO 15859 Aerospace Fluid Standards
NASA Technical Reports Server (NTRS)
Greene, Benjamin; McClure, Mark B.
2012-01-01
A detailed review of ISO 15859 "Space Systems - Fluid Characteristics, Sampling and Test Methods" was performed An approach to revising Parts 1-9 and 11-13 was developed and concurred by the NASA Technical Standards Program Office. The approach was to align them with the highest level source documents, and not to program-specific requirements. The updated documents were prepared and presented.
The George C. Marshall Space Flight Center High Reynolds Number Wind Tunnel Technical Handbook
NASA Technical Reports Server (NTRS)
Gwin, H. S.
1975-01-01
The High Reynolds Number Wind Tunnel at the George C. Marshall Space Flight Center is described. The following items are presented to illustrate the operation and capabilities of the facility: facility descriptions and specifications, operational and performance characteristics, model design criteria, instrumentation and data recording equipment, data processing and presentation, and preliminary test information required.
Development of a dc motor with virtually zero powered magnetic bearing
NASA Technical Reports Server (NTRS)
1971-01-01
The development of magnetic bearings for use in direct current electric motors is discussed. The characteristics of the magnets used in the construction of the bearings are described. A magnetic bearing using steel armoring on permanent magnets was selected for performance tests. The specifications of the motor are presented. The test equipment used in the evaluation is described.
Multi-mission Ni-H2 battery cells for the 1990's
NASA Technical Reports Server (NTRS)
Miller, Lee; Brill, Jack; Dodson, Gary
1989-01-01
A sufficient production, test and operational database is now available to permit design technology optimization for the next decade. The evolved battery cell design features standardized technology intended to support multiple type missions (e.g., both GEO and LEO). Design analysis and validation test cells demonstrate that improved performance plus attractive specific-energy characteristics will be achieved.
ERIC Educational Resources Information Center
National Academy of Sciences - National Research Council, Washington, DC.
Publication of conference paper texts include --(1) history and development of masonry cavity walls, (2) recent research related to determination of thermal and moisture resistance, (3) wall design and detailing, (4) design for crack prevention, (5) mortar specification characteristics, (6) performance experience with low-rise buildings, (7)…
NASA Technical Reports Server (NTRS)
1976-01-01
Inputs from prospective LANDSAT-C data users are requested to aid NASA in defining LANDSAT-C mission and data requirements and in making decisions regarding the scheduling of satellite operations and ground data processing operations. Design specifications, multispectral band scanner performance characteristics, satellite schedule operations, and types of available data products are briefly described.
Biological characterization of metanephric mesenchymal stem cells from the Beijing duck.
Chen, Jia; Pu, Yabin; Sun, Yujiao; Zhang, Ping; Li, Qian; Wang, Kunfu; Wang, Wenjie; Ma, Yuehui; Guan, Weijun
2016-02-01
Mesenchymal stem cells (MSCs) possess self-proliferation and multi-directional differentiation abilities. Previous studies on MSCs have mostly focused on the bone marrow, lungs, pancreas and umbilical cord blood, with few studies on metanephric tissues in ducks. For the present study, the Beijing duck was selected as an experimental animal. Duck embryo metanephric mesenchymal stem cells (MMSCs) were studied. MMSC isolation culture, analysis of biological characteristics, induced differentiation and identification were performed in preliminary experiments. In the current study, surface antigens and gene expression patterns were detected using immunofluorescence, reverse transcription-polymerase chain reaction (RT-PCR) and flow cytometry. The induced cells, adipocytes, hepatocytes, epithelial cells and islet cells were identified by oil red O staining, periodic acid-Schiff staining, immunofluorescence and dithizone staining, respectively. RT-PCR was performed for detection of specific marker genes. The results suggested that the biological characteristics of MMSCs were similar to those of the MSCs previously analyzed. Primary MMSCs were sub-cultured to passage 21. The induced cells exhibit typical staining and immunofluorescence indicating the expression of specific genes. This demonstrates that MMSCs may be a novel alternative source of MSCs for experimental and clinical applications.
A hospital-specific template for benchmarking its cost and quality.
Silber, Jeffrey H; Rosenbaum, Paul R; Ross, Richard N; Ludwig, Justin M; Wang, Wei; Niknam, Bijan A; Saynisch, Philip A; Even-Shoshan, Orit; Kelz, Rachel R; Fleisher, Lee A
2014-10-01
Develop an improved method for auditing hospital cost and quality tailored to a specific hospital's patient population. Medicare claims in general, gynecologic and urologic surgery, and orthopedics from Illinois, New York, and Texas between 2004 and 2006. A template of 300 representative patients from a single index hospital was constructed and used to match 300 patients at 43 hospitals that had a minimum of 500 patients over a 3-year study period. From each of 43 hospitals we chose 300 patients most resembling the template using multivariate matching. We found close matches on procedures and patient characteristics, far more balanced than would be expected in a randomized trial. There were little to no differences between the index hospital's template and the 43 hospitals on most patient characteristics yet large and significant differences in mortality, failure-to-rescue, and cost. Matching can produce fair, directly standardized audits. From the perspective of the index hospital, "hospital-specific" template matching provides the fairness of direct standardization with the specific institutional relevance of indirect standardization. Using this approach, hospitals will be better able to examine their performance, and better determine why they are achieving the results they observe. © Health Research and Educational Trust.
Plutonium Finishing Plant (PFP) HVAC System Component Index
DOE Office of Scientific and Technical Information (OSTI.GOV)
DICK, J.D.
2000-02-28
The Plutonium Finishing Plant (PFP) WAC System includes sub-systems 25A through 25K. Specific system boundaries and justifications are contained in HNF-SD-CP-SDD-005, ''Definition and Means of Maintaining the Ventilation System Confinement Portion of the PFP Safety Envelope.'' The procurement requirements associated with the system necessitates procurement of some system equipment as Commercial Grade Items in accordance with HNF-PRO-268, ''Control of Purchased Items and Services.'' This document lists safety class and safety significant components for the Heating Ventilation Air Conditioning and specifies the critical characteristics for Commercial Grade Items, as required by HNF-PRO-268 and HNF-PRO-1819. These are the minimum specifications that themore » equipment must meet in order to properly perform its safety function. There may be several manufacturers or models that meet the critical characteristics for any one item.« less
NASA Technical Reports Server (NTRS)
Yushin, Gleb; Evanoff, Kara; Magasinski, Alexander
2012-01-01
Thin Si films coated on porous 3D particles composed of curved 2D graphene sheets have been synthesized utilizing techniques that allow for tunable properties. Since graphene exhibits specific surface area up to 100 times higher than carbon black or graphite, the deposition of the same mass of Si on graphene is much faster in comparison -- a factor which is important for practical applications. In addition, the distance between graphene layers is tunable and variation in the thickness of the deposited Si film is feasible. Both of these characteristics allow for optimization of the energy and power characteristics. Thicker films will allow higher capacity, but slower rate capabilities. Thinner films will allow more rapid charging, or higher power performance. In this innovation, uniform deposition of Si and C layers on high-surface area graphene produced granules with specific surface area (SSA) of 5 sq. m/g.
Fazio, Rachel L; Sanders, James Forrest; Denney, Robert L
2015-06-01
Compared with the amount of neuropsychological literature surrounding response bias in civil litigation, there is little regarding criminal cases. This study adds to the criminal forensic neuropsychological literature by comparing the Test of Memory Malingering (TOMM) and the Word Memory Test (WMT) in a criminal forensic setting utilizing a criterion-groups design. Subjects were classified into two groups based on their performance on at least two other freestanding performance validity tests. The WMT demonstrated good sensitivity (95.1%) but poor specificity (68.4%) when Genuine Memory Impaired Profiles (GMIPs) were not considered. Inclusion of GMIPs reduced the sensitivity to 56.1% but increased the specificity to 94.7%. The TOMM evidenced better sensitivity but poorer specificity than the WMT with GMIPs. Conjoint use of the tests was also considered. Receiver operating characteristics and other classification statistics for each measure are presented. Results support the use of these measures in a criminal forensic population. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Saito, Takaya; Rehmsmeier, Marc
2015-01-01
Binary classifiers are routinely evaluated with performance measures such as sensitivity and specificity, and performance is frequently illustrated with Receiver Operating Characteristics (ROC) plots. Alternative measures such as positive predictive value (PPV) and the associated Precision/Recall (PRC) plots are used less frequently. Many bioinformatics studies develop and evaluate classifiers that are to be applied to strongly imbalanced datasets in which the number of negatives outweighs the number of positives significantly. While ROC plots are visually appealing and provide an overview of a classifier's performance across a wide range of specificities, one can ask whether ROC plots could be misleading when applied in imbalanced classification scenarios. We show here that the visual interpretability of ROC plots in the context of imbalanced datasets can be deceptive with respect to conclusions about the reliability of classification performance, owing to an intuitive but wrong interpretation of specificity. PRC plots, on the other hand, can provide the viewer with an accurate prediction of future classification performance due to the fact that they evaluate the fraction of true positives among positive predictions. Our findings have potential implications for the interpretation of a large number of studies that use ROC plots on imbalanced datasets.
Derntl, Birgit; Seidel, Eva-Maria; Schneider, Frank; Habel, Ute
2012-01-01
Empathy is a rather elaborated human ability and several recent studies highlight significant impairments in patients suffering from psychiatric disorders, such as schizophrenia, bipolar disorder or major depression. Therefore, the present study aimed at comparing behavioral empathy performance in schizophrenia, bipolar and depressed patients with healthy controls. All subjects performed three tasks tapping the core components of empathy: emotion recognition, emotional perspective taking and affective responsiveness. Groups were matched for age, gender, and verbal intelligence. Data analysis revealed three main findings: First, schizophrenia patients showed the strongest impairment in empathic performance followed by bipolar patients while depressed patients performed similar to controls in most tasks, except for affective responsiveness. Second, a significant association between clinical characteristics and empathy performance was only apparent in depression, indicating worse affective responsiveness with stronger symptom severity and longer duration of illness. Third, self-report data indicate that particularly bipolar patients describe themselves as less empathic, reporting less empathic concern and less perspective taking. Taken together, this study constitutes the first approach to directly compare specificity of empathic deficits in severe psychiatric disorders. Our results suggest disorder-specific impairments in emotional competencies that enable better characterization of the patient groups investigated and indicate different psychotherapeutic interventions. PMID:23116884
Experimental clean combustor program, alternate fuels addendum, phase 2
NASA Technical Reports Server (NTRS)
Gleason, C. C.; Bahr, D. W.
1976-01-01
The characteristics of current and advanced low-emissions combustors when operated with special test fuels simulating broader range combustion properties of petroleum or coal derived fuels were studied. Five fuels were evaluated; conventional JP-5, conventional No. 2 Diesel, two different blends of Jet A and commercial aromatic mixtures - zylene bottoms and haphthalene charge stock, and a fuel derived from shale oil crude which was refined to Jet A specifications. Three CF6-50 engine size combustor types were evaluated; the standard production combustor, a radial/axial staged combustor, and a double annular combustor. Performance and pollutant emissons characteristics at idle and simulated takeoff conditions were evaluated in a full annular combustor rig. Altitude relight characteristics were evaluated in a 60 degree sector combustor rig. Carboning and flashback characteristics at simulated takeoff conditions were evaluated in a 12 degree sector combustor rig. For the five fuels tested, effects were moderate, but well defined.
A systematic review of the factors predicting the interest in cosmetic plastic surgery.
Milothridis, Panagiotis; Pavlidis, Leonidas; Haidich, Anna-Bettina; Panagopoulou, Efharis
2016-01-01
A systematic review of the literature was performed to clarify the psychosocial characteristics of patients who have an interest in cosmetic plastic surgery. Medical literature was reviewed by two independent researchers, and a third reviewer evaluated their results. Twelve studies addressing the predictors of interest in cosmetic surgery were finally identified and analysed. Interest in cosmetic surgery was associated with epidemiological factors, their social networks, their psychological characteristics, such as body image, self-esteem and other personality traits and for specific psychopathology and found that these may either positively or negatively predict their motivation to seek and undergo a cosmetic procedure. The review examined the psychosocial characteristics associated with an interest in cosmetic surgery. Understanding cosmetic patients' characteristics, motivation and expectation for surgery is an important aspect of their clinical care to identify those patients more likely to benefit most from the procedure.
Dore, Kelly L; Reiter, Harold I; Kreuger, Sharyn; Norman, Geoffrey R
2017-05-01
Typically, only a minority of applicants to health professional training are invited to interview. However, pre-interview measures of cognitive skills predict for national licensure scores (Gauer et al. in Med Educ Online 21 2016) and subsequently licensure scores predict for performance in practice (Tamblyn et al. in JAMA 288(23): 3019-3026, 2002; Tamblyn et al. in JAMA 298(9):993-1001, 2007). Assessment of personal and professional characteristics, with the same psychometric rigour of measures of cognitive abilities, are needed upstream in the selection to health profession training programs. To fill that need, Computer-based Assessment for Sampling Personal characteristics (CASPer)-an on-line, video-based screening test-was created. In this paper, we examine the correlation between CASPer and Canadian national licensure examination outcomes in 109 doctors who took CASPer at the time of selection to medical school. Specifically, CASPer scores were correlated against performance on cognitive and 'non-cognitive' subsections of both the Medical Council of Canada Qualifying Examination (MCCQE) Parts I (end of medical school) and Part II (18 months into specialty training). Unlike most national licensure exams, MCCQE has specific subcomponents examining personal/professional qualities, providing a unique opportunity for comparison. The results demonstrated moderate predictive validity of CASPer to national licensure outcomes of personal/professional characteristics three to six years after admission to medical school. These types of disattenuated correlations (r = 0.3-0.5) are not otherwise predicted by traditional screening measures. These data support the ability of a computer-based strategy to screen applicants in a feasible, reliable test, which has now demonstrated predictive validity, lending evidence of its validation for medical school applicant selection.
Lewinski, Peter
2015-01-01
This mini literature review analyzes research papers from many countries that directly or indirectly test how classrooms' architecture influences academic performance. These papers evaluate and explain specific characteristics of classrooms, with an emphasis on how they affect learning processes and learning outcomes. Factors such as acoustics, light, color, temperature, and seat arrangement are scrutinized to determine whether and by how much they improve or hinder students' academic performance in classrooms. Apter's (1982, 1984, 2014) reversal theory of telic versus paratelic motivation is presented and used to explain these findings. The results show preference for a learning environment that cues a telic motivation state in the students. Therefore, classroom features should not be distracting or arousing. Moreover, it appears the most influential factors affecting the learning process are noise, temperature and seat arrangement. In addition, there is no current agreement on how some particular physical characteristics of classrooms affect learning outcomes. More research is needed to establish stronger conclusions and recommendations.
Guo, Cheng-Long; Cao, Hong-Xia; Pei, Hong-Shan; Guo, Fei-Qiang; Liu, Da-Meng
2015-04-01
A multiphase mixture model was developed for revealing the interaction mechanism between biochemical reactions and transfer processes in the entrapped-cell photobioreactor packed with gel granules containing Rhodopseudomonas palustris CQK 01. The effects of difference operation parameters, including operation temperature, influent medium pH value and porosity of packed bed, on substrate concentration distribution characteristics and photo-hydrogen production performance were investigated. The results showed that the model predictions were in good agreement with the experimental data reported. Moreover, the operation temperature of 30 °C and the influent medium pH value of 7 were the most suitable conditions for photo-hydrogen production by biodegrading substrate. In addition, the lower porosity of packed bed was beneficial to enhance photo-hydrogen production performance owing to the improvement on the amount of substrate transferred into gel granules caused by the increased specific area for substrate transfer in the elemental volume. Copyright © 2015 Elsevier Ltd. All rights reserved.
Contemporary management of benign liver tumors.
Gibbs, John F; Litwin, Alan M; Kahlenberg, Morton S
2004-04-01
Benign lesions of the liver represent diagnostic dilemmas, clinically and radiographically; however, certain clues can help the extensive differential diagnosis of both benign and malignant processes. Hemangiomas and simple cysts have very distinct and very specific radiographic characteristics, and if diagnosed, no further work-up is necessary. The remaining benign lesions have significant overlap, even though there are some more common characteristics to each of the entities. Still, differentiation of any particular lesion outside simple cysts or hemangioma may be difficult. It is reasonable and relatively simple, with minimal invasiveness, to perform US- or CT-guided, percutaneous core-needle biopsies. It is recommended that core biopsies be performed, because many of the benign entities have some overlapping histologic features, and if fine-needle aspirations are performed, a definitive diagnosis may be difficult to obtain. A definitive pathological diagnosis still cannot be made in some cases, even after needle biopsy. Therefore, a surgical resection or wedge resection may be necessary if a benign process cannot be definitively ruled out.
Combustion performance and heat transfer characterization of LOX/hydrocarbon type propellants
NASA Technical Reports Server (NTRS)
Michel, R. W.
1983-01-01
An evaluation liquid oxygen (LOX) and various hydrocarbon fuels as low cost alternative propellants suitable for future space transportation system applications was done. The emphasis was directed toward low earth orbit maneuvering engine and reaction control engine systems. The feasibility of regeneratively cooling an orbit maneuvering thruster was analytically determined over a range of operating conditions from 100 to 1000 psia chamber pressure and 1000 to 10,000-1bF thrust, and specific design points were analyzed in detail for propane, methane, RP-1, ammonia, and ethanol; similar design point studies were performed for a film-cooled reaction control thruster. Heat transfer characteristics of propane were experimentally evaluated in heated tube tests. Forced convection heat transfer coefficients were determined. Seventy-seven hot firing tests were conducted with LOX/propane and LOX/ethanol, for a total duration of nearly 1400 seconds, using both heat sink and water-cooled calorimetric chambers. Combustion performance and stability and gas-side heat transfer characteristics were evaluated.
Man, Wanrong; Hu, Jianqiang; Zhao, Zhijing; Zhang, Mingming; Wang, Tingting; Lin, Jie; Duan, Yu; Wang, Ling; Wang, Haichang; Sun, Dongdong; Li, Yan
2016-09-01
The instantaneous wave-free ratio (iFR) is a new vasodilator-free index of coronary stenosis severity. The aim of this meta-analysis is to assess the diagnostic performance of iFR for the evaluation of coronary stenosis severity with fractional flow reserve as standard reference. We searched PubMed, EMBASE, CENTRAL, ProQuest, Web of Science, and International Clinical Trials Registry Platform (ICTRP) for publications concerning the diagnostic value of iFR. We used a random-effects covariate to synthesize the available data of sensitivity, specificity, positive likelihood ratio (LR+), negative likelihood ratio (LR-), and diagnostic odds ratio (DOR). Overall test performance was summarized by the summary receiver operating characteristic curve (sROC) and the area under the curve (AUC). Eight studies with 1611 subjects were included in the meta-analysis. The pooled sensitivity, specificity, LR+, LR-, and DOR for iFR were respectively 73.3% (70.1-76.2%), 86.4% (84.3-88.3%), 5.71 (4.43-7.37), 0.29 (0.22-0.38), and 20.54 (16.11-26.20). The area under the summary receiver operating characteristic curves for iFR was 0.8786. No publication bias was identified. The available evidence suggests that iFR may be a new, simple, and promising technology for coronary stenosis physiological assessment.
Effect of lithium and sodium salt on the performance of Nb2O5/rGO nanocomposite based supercapacitor
NASA Astrophysics Data System (ADS)
Ahmed, Sultan; Rafat, M.
2018-03-01
The present work reports the synthesis of Nb2O5/rGO composite using hydrothermal method and thermal annealing process. The prepared composite was found to have suitable characteristics necessary to be used as electrode material in supercapacitors. These characteristics were ascertained employing the techniques of scanning electron microscopy (SEM), x-ray diffraction (XRD), Raman spectroscopy and N2 adsorption-desorption isotherm. Further, the electrochemical performance of the prepared composite was compared in two different organic electrolytes, of lithium and sodium salt using the techniques of electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and charge-discharge measurements. The organic electrolyte solutions were prepared by dispersing 1 M LiClO4/NaClO4 in a mixture of ethylene carbonate/propylene carbonate (1:1 by volume). The observed results indicate that the composite of Nb2O5/rGO offers higher value of specific capacitance in sodium salt electrolyte and higher cyclic stability in lithium salt electrolyte. This is probably due to ion properties of electrolyte. Specific capacitance is observed according to efficient ion/charge diffusion/exchange and relaxation time (Li+ < Na+), while the cyclic stability is observed according to cation size (Na+ > Li+). Thus, the present study reveals the significant effect of electrolyte ions on electrochemical performance of Nb2O5/rGO composite.
Flat-panel cone-beam CT: a novel imaging technology for image-guided procedures
NASA Astrophysics Data System (ADS)
Siewerdsen, Jeffrey H.; Jaffray, David A.; Edmundson, Gregory K.; Sanders, W. P.; Wong, John W.; Martinez, Alvaro A.
2001-05-01
The use of flat-panel imagers for cone-beam CT signals the emergence of an attractive technology for volumetric imaging. Recent investigations demonstrate volume images with high spatial resolution and soft-tissue visibility and point to a number of logistical characteristics (e.g., open geometry, volume acquisition in a single rotation about the patient, and separation of the imaging and patient support structures) that are attractive to a broad spectrum of applications. Considering application to image-guided (IG) procedures - specifically IG therapies - this paper examines the performance of flat-panel cone-beam CT in relation to numerous constraints and requirements, including time (i.e., speed of image acquisition), dose, and field-of-view. The imaging and guidance performance of a prototype flat panel cone-beam CT system is investigated through the construction of procedure-specific tasks that test the influence of image artifacts (e.g., x-ray scatter and beam-hardening) and volumetric imaging performance (e.g., 3D spatial resolution, noise, and contrast) - taking two specific examples in IG brachytherapy and IG vertebroplasty. For IG brachytherapy, a procedure-specific task is constructed which tests the performance of flat-panel cone-beam CT in measuring the volumetric distribution of Pd-103 permanent implant seeds in relation to neighboring bone and soft-tissue structures in a pelvis phantom. For IG interventional procedures, a procedure-specific task is constructed in the context of vertebroplasty performed on a cadaverized ovine spine, demonstrating the volumetric image quality in pre-, intra-, and post-therapeutic images of the region of interest and testing the performance of the system in measuring the volumetric distribution of bone cement (PMMA) relative to surrounding spinal anatomy. Each of these tasks highlights numerous promising and challenging aspects of flat-panel cone-beam CT applied to IG procedures.
Pion, Johan; Segers, Veerle; Fransen, Job; Debuyck, Gijs; Deprez, Dieter; Haerens, Leen; Vaeyens, Roel; Philippaerts, Renaat; Lenoir, Matthieu
2015-01-01
The aim of the present study was to evaluate the Flemish Sports Compass (FSC), a non-sport-specific generic testing battery. It was hypothesised that a set of 22 tests would have sufficient discriminant power to allocate athletes to their own sport based on a unique combination of test scores. First, discriminant analyses were applied to the 22 tests of anthropometry, physical fitness and motor coordination in 141 boys under age 18 (16.1 ± 0.8 years) and post age at peak height velocity (maturity offset = 2.674 ± 0.926) from Flemish Top Sport Academies for badminton, basketball, gymnastics, handball, judo, soccer, table tennis, triathlon and volleyball. Second, nine sequential discriminant analyses were used to assess the ability of a set of relevant performance characteristics classifying participants and non-participants for the respective sports. Discriminant analyses resulted in a 96.4% correct classification of all participants for the nine different sports. When focusing on relevant performance characteristics, 80.1% to 97.2% of the total test sample was classified correctly within their respective disciplines. The discriminating characteristics were briefly the following: flexibility in gymnastics, explosive lower-limb strength in badminton and volleyball, speed and agility in badminton, judo, soccer and volleyball, upper-body strength in badminton, basketball and gymnastics, cardiorespiratory endurance in triathletes, dribbling skills in handball, basketball and soccer and overhead-throwing skills in badminton and volleyball. The generic talent characteristics of the FSC enable the distinction of adolescent boys according to their particular sport. Implications for talent programmes are discussed.
Performance Evaluation of Bluetooth Low Energy: A Systematic Review.
Tosi, Jacopo; Taffoni, Fabrizio; Santacatterina, Marco; Sannino, Roberto; Formica, Domenico
2017-12-13
Small, compact and embedded sensors are a pervasive technology in everyday life for a wide number of applications (e.g., wearable devices, domotics, e-health systems, etc.). In this context, wireless transmission plays a key role, and among available solutions, Bluetooth Low Energy (BLE) is gaining more and more popularity. BLE merges together good performance, low-energy consumption and widespread diffusion. The aim of this work is to review the main methodologies adopted to investigate BLE performance. The first part of this review is an in-depth description of the protocol, highlighting the main characteristics and implementation details. The second part reviews the state of the art on BLE characteristics and performance. In particular, we analyze throughput, maximum number of connectable sensors, power consumption, latency and maximum reachable range, with the aim to identify what are the current limits of BLE technology. The main results can be resumed as follows: throughput may theoretically reach the limit of ~230 kbps, but actual applications analyzed in this review show throughputs limited to ~100 kbps; the maximum reachable range is strictly dependent on the radio power, and it goes up to a few tens of meters; the maximum number of nodes in the network depends on connection parameters, on the network architecture and specific device characteristics, but it is usually lower than 10; power consumption and latency are largely modeled and analyzed and are strictly dependent on a huge number of parameters. Most of these characteristics are based on analytical models, but there is a need for rigorous experimental evaluations to understand the actual limits.
Performance Evaluation of Bluetooth Low Energy: A Systematic Review
Taffoni, Fabrizio; Santacatterina, Marco; Sannino, Roberto
2017-01-01
Small, compact and embedded sensors are a pervasive technology in everyday life for a wide number of applications (e.g., wearable devices, domotics, e-health systems, etc.). In this context, wireless transmission plays a key role, and among available solutions, Bluetooth Low Energy (BLE) is gaining more and more popularity. BLE merges together good performance, low-energy consumption and widespread diffusion. The aim of this work is to review the main methodologies adopted to investigate BLE performance. The first part of this review is an in-depth description of the protocol, highlighting the main characteristics and implementation details. The second part reviews the state of the art on BLE characteristics and performance. In particular, we analyze throughput, maximum number of connectable sensors, power consumption, latency and maximum reachable range, with the aim to identify what are the current limits of BLE technology. The main results can be resumed as follows: throughput may theoretically reach the limit of ~230 kbps, but actual applications analyzed in this review show throughputs limited to ~100 kbps; the maximum reachable range is strictly dependent on the radio power, and it goes up to a few tens of meters; the maximum number of nodes in the network depends on connection parameters, on the network architecture and specific device characteristics, but it is usually lower than 10; power consumption and latency are largely modeled and analyzed and are strictly dependent on a huge number of parameters. Most of these characteristics are based on analytical models, but there is a need for rigorous experimental evaluations to understand the actual limits. PMID:29236085
da Silva, Richardson Augusto Rosendo; Costa, Mayara Mirna do Nascimento; de Souza, Vinicius Lino; da Silva, Bárbara Coeli Oliveira; Costa, Cristiane da Silva; de Andrade, Itaísa Fernandes Cardoso
2017-01-01
ABSTRACT Objective: to evaluate the accuracy of the defining characteristics of the NANDA International nursing diagnosis, noncompliance, in people with HIV. Method: study of diagnostic accuracy, performed in two stages. In the first stage, 113 people with HIV from a hospital of infectious diseases in the Northeast of Brazil were assessed for identification of clinical indicators of noncompliance. In the second, the defining characteristics were evaluated by six specialist nurses, analyzing the presence or absence of the diagnosis. For accuracy of the clinical indicators, the specificity, sensitivity, predictive values and likelihood ratios were measured. Results: the presence of the noncompliance diagnosis was shown in 69% (n=78) of people with HIV. The most sensitive indicator was, missing of appointments (OR: 28.93, 95% CI: 1.112-2.126, p = 0.002). On the other hand, nonadherence behavior (OR: 15.00, 95% CI: 1.829-3.981, p = 0.001) and failure to meet outcomes (OR: 13.41; 95% CI: 1.272-2.508; P = 0.003) achieved higher specificity. Conclusion: the most accurate defining characteristics were nonadherence behavior, missing of appointments, and failure to meet outcomes. Thus, in the presence of these, the nurse can identify, with greater security, the diagnosis studied. PMID:29091125
de la Serna, Elena; Sugranyes, Gisela; Sanchez-Gistau, Vanessa; Rodriguez-Toscano, Elisa; Baeza, Immaculada; Vila, Montserrat; Romero, Soledad; Sanchez-Gutierrez, Teresa; Penzol, Mª José; Moreno, Dolores; Castro-Fornieles, Josefina
2017-05-01
Schizophrenia (SZ) and bipolar disorder (BD) are considered neurobiological disorders which share some clinical, cognitive and neuroimaging characteristics. Studying child and adolescent offspring of patients diagnosed with bipolar disorder (BDoff) or schizophrenia (SZoff) is regarded as a reliable method for investigating early alterations and vulnerability factors for these disorders. This study compares the neuropsychological characteristics of SZoff, BDoff and a community control offspring group (CC) with the aim of examining shared and differential cognitive characteristics among groups. 41 SZoff, 90 BDoff and 107 CC were recruited. They were all assessed with a complete neuropsychological battery which included intelligence quotient, working memory (WM), processing speed, verbal memory and learning, visual memory, executive functions and sustained attention. SZoff and BDoff showed worse performance in some cognitive areas compared with CC. Some of these difficulties (visual memory) were common to both offspring groups, whereas others, such as verbal learning and WM in SZoff or PSI in BDoff, were group-specific. The cognitive difficulties in visual memory shown by both the SZoff and BDoff groups might point to a common endophenotype in the two disorders. Difficulties in other cognitive functions would be specific depending on the family diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.
Ali, Innocent M; Bigoga, Jude D; Forsah, Dorothy A; Cho-Ngwa, Fidelis; Tchinda, Vivian; Moor, Vicky Ama; Fogako, Josephine; Nyongalema, Philomena; Nkoa, Theresa; Same-Ekobo, Albert; Mbede, Joseph; Fondjo, Etienne; Mbacham, Wilfred F; Leke, Rose G F
2016-01-20
All suspected cases of malaria should receive a diagnostic test prior to treatment with artemisinin-based combinations based on the new WHO malaria treatment guidelines. This study compared the accuracy and some operational characteristics of 22 different immunochromatographic antigen capture point-of- malaria tests (RDTs) in Cameroon to inform test procurement prior to deployment of artemisinin-based combinations for malaria treatment. One hundred human blood samples (50 positive and 50 negative) collected from consenting febrile patients in two health centres at Yaoundé were used for evaluation of the 22 RDTs categorized as "Pf Only" (9) or "Pf + PAN" (13) based on parasite antigen captured [histidine rich protein II (HRP2) or lactate dehydrogenase (pLDH) or aldolase]. RDTs were coded to blind technicians performing the tests. The sensitivity, specificity, and predictive values of the positive and negative tests (PPV and NPV) as well as the likelihood ratios were assessed. The reliability and some operational characteristics were determined as the mean values from two assessors, and the Cohen's kappa statistic was then used to compare agreement. Light microscopy was the referent. Of all RDTs tested, 94.2 % (21/22) had sensitivity values greater than 90% among which 14 (63.6%) were 'Pf + PAN' RDTs. The specificity was generally lower than the sensitivity for all RDTs and poorer for "Pf Only" RDTs. The predictive values and likelihood ratios were better for non-HRP2 analytes for "Pf + PAN" RDTs. The Kappa value for most of the tests obtained was around 67% (95% CI 50-69%), corresponding to a moderate agreement. Overall, 94.2% (21/22) of RDTs tested had accuracy within the range recommended by the WHO, while one performed poorly, below acceptable levels. Seven "Pf + PAN" and 3 "Pf Only" RDTs were selected for further assessment based on performance characteristics. Harmonizing RDT test presentation and procedures would prevent mistakes of test performance and interpretation.
Assessment of railway wagon suspension characteristics
NASA Astrophysics Data System (ADS)
Soukup, Josef; Skočilas, Jan; Skočilasová, Blanka
2017-05-01
The article deals with assessment of railway wagon suspension characteristics. The essential characteristics of a suspension are represented by the stiffness constants of the equivalent springs and the eigen frequencies of the oscillating movements in reference to the main central inertia axes of a vehicle. The premise of the experimental determination of these characteristic is the knowledge of the gravity center position and the knowledge of the main central inertia moments of the vehicle frame. The vehicle frame performs the general spatial movement when the vehicle moves. An analysis of the frame movement generally arises from Euler's equations which are commonly used for the description of the spherical movement. This solution is difficult and it can be simplified by applying the specific assumptions. The eigen frequencies solutions and solutions of the suspension stiffness are presented in the article. The solutions are applied on the railway and road vehicles with the simplifying conditions. A new method which assessed the characteristics is described in the article.
Selection of the battery pack parameters for an electric vehicle based on performance requirements
NASA Astrophysics Data System (ADS)
Koniak, M.; Czerepicki, A.
2017-06-01
Each type of vehicle has specific power requirements. Some require a rapid charging, other make long distances between charges, but a common feature is the longest battery life time. Additionally, the battery is influenced by factors such as temperature, depth of discharge and the operation current. The article contain the parameters of chemical cells that should be taken into account during the design of the battery for a specific application. This is particularly important because the batteries are not properly matched and can wear prematurely and cause an additional costs. The method of selecting the correct cell type should take previously discussed features and operating characteristics of the vehicle into account. The authors present methods of obtaining such characteristics along with their assessment and examples. Also there has been described an example of the battery parameters selection based on design assumptions of the vehicle and the expected performance characteristics. Selecting proper battery operating parameters is important due to its impact on the economic result of investments in electric vehicles. For example, for some Li-Ion technologies, the earlier worn out of batteries in a fleet of cruise boats or buses having estimated lifetime of 10 years is not acceptable, because this will cause substantial financial losses for the owner of the rolling stock. The presented method of choosing the right cell technology in the selected application, can be the basis for making the decision on future battery technical parameters.
Cheng, Tao; Yu, Baozhi; Cao, Linli; Tan, Huiyun; Li, Xinghua; Zheng, Xinliang; Li, Weilong; Ren, Zhaoyu; Bai, Jinbo
2017-09-01
The ternary composite electrodes, nitrogen-doped graphene foam/carbon nanotube/manganese dioxide (NGF/CNT/MnO 2 ), have been successfully fabricated via chemical vapor deposition (CVD) and facile hydrothermal method. The morphologies of the MnO 2 nanoflakes presented the loading-dependent characteristics and the nanoflake thickness could also be tuned by MnO 2 mass loading in the fabrication process. The correlation between their morphology and electrochemical performance was systematically investigated by controlling MnO 2 mass loading in the ternary composite electrodes. The electrochemical properties of the flexible ternary electrode (MnO 2 mass loading of 70%) exhibited a high areal capacitance of 3.03F/cm 2 and a high specific capacitance of 284F/g at the scan rate of 2mV/s. Moreover, it was interesting to find that the capacitance of the NGF/CNT/MnO 2 composite electrodes showed a 51.6% increase after 15,000 cycles. The gradual increase in specific capacitance was due to the formation of defective regions in the MnO 2 nanostructures during the electrochemical cycles of the electrodes, which further resulted in increased porosity, surface area, and consequently increased electrochemical capacity. This work demonstrates a rarely reported conclusion about loading-dependent characteristics for the NGF/CNT/MnO 2 ternary composite electrodes. It will bring new perspectives on designing novel ternary or multi-structure for various energy storage applications. Copyright © 2017 Elsevier Inc. All rights reserved.
WOMBAT: A Scalable and High-performance Astrophysical Magnetohydrodynamics Code
NASA Astrophysics Data System (ADS)
Mendygral, P. J.; Radcliffe, N.; Kandalla, K.; Porter, D.; O'Neill, B. J.; Nolting, C.; Edmon, P.; Donnert, J. M. F.; Jones, T. W.
2017-02-01
We present a new code for astrophysical magnetohydrodynamics specifically designed and optimized for high performance and scaling on modern and future supercomputers. We describe a novel hybrid OpenMP/MPI programming model that emerged from a collaboration between Cray, Inc. and the University of Minnesota. This design utilizes MPI-RMA optimized for thread scaling, which allows the code to run extremely efficiently at very high thread counts ideal for the latest generation of multi-core and many-core architectures. Such performance characteristics are needed in the era of “exascale” computing. We describe and demonstrate our high-performance design in detail with the intent that it may be used as a model for other, future astrophysical codes intended for applications demanding exceptional performance.
Bayesian semiparametric estimation of covariate-dependent ROC curves
Rodríguez, Abel; Martínez, Julissa C.
2014-01-01
Receiver operating characteristic (ROC) curves are widely used to measure the discriminating power of medical tests and other classification procedures. In many practical applications, the performance of these procedures can depend on covariates such as age, naturally leading to a collection of curves associated with different covariate levels. This paper develops a Bayesian heteroscedastic semiparametric regression model and applies it to the estimation of covariate-dependent ROC curves. More specifically, our approach uses Gaussian process priors to model the conditional mean and conditional variance of the biomarker of interest for each of the populations under study. The model is illustrated through an application to the evaluation of prostate-specific antigen for the diagnosis of prostate cancer, which contrasts the performance of our model against alternative models. PMID:24174579
Testing and evaluation of the LES-6 pulsed plasma thruster by means of a torsion pendulum system
NASA Technical Reports Server (NTRS)
Hamidian, J. P.; Dahlgren, J. B.
1973-01-01
Performance characteristics of the LES-6 pulsed plasma thruster over a range of input conditions were investigated by means of a torsion pendulum system. Parameters of particular interest included the impulse bit and time average thrust (and their repeatability), specific impulse, mass ablated per discharge, specific thrust, energy per unit area, efficiency, and variation of performance with ignition command rate. Intermittency of the thruster as affected by input energy and igniter resistance were also investigated. Comparative experimental data correlation with the data presented. The results of these tests indicate that the LES-6 thruster, with some identifiable design improvements, represents an attractive reaction control thruster for attitude contol applications on long-life spacecraft requiring small metered impulse bits for precise pointing control of science instruments.
Santani, Avni; Murrell, Jill; Funke, Birgit; Yu, Zhenming; Hegde, Madhuri; Mao, Rong; Ferreira-Gonzalez, Andrea; Voelkerding, Karl V; Weck, Karen E
2017-06-01
- The number of targeted next-generation sequencing (NGS) panels for genetic diseases offered by clinical laboratories is rapidly increasing. Before an NGS-based test is implemented in a clinical laboratory, appropriate validation studies are needed to determine the performance characteristics of the test. - To provide examples of assay design and validation of targeted NGS gene panels for the detection of germline variants associated with inherited disorders. - The approaches used by 2 clinical laboratories for the development and validation of targeted NGS gene panels are described. Important design and validation considerations are examined. - Clinical laboratories must validate performance specifications of each test prior to implementation. Test design specifications and validation data are provided, outlining important steps in validation of targeted NGS panels by clinical diagnostic laboratories.
Harper, Lorie M; Gray, Diana; Dicke, Jeffrey; Stamilio, David M; Macones, George A; Odibo, Anthony O
2010-02-01
The purpose of this study was to determine whether the use of race-specific definitions of short femur and humerus lengths improves Down syndrome detection. This was a retrospective cohort study over 16 years. For each self-reported maternal race (white, African American, Hispanic, and Asian), we evaluated the efficiency of Down syndrome detection using published race-specific formulas compared with a standard formula for short femur and humerus lengths (observed versus expected lengths < or =0.91 and < or =0.89, respectively). The sensitivity, specificity, and 95% confidence intervals for each parameter were compared. Screening performance was compared by areas under the receiver operating characteristic curves. Of 58,710 women, 209 (0.3%) had a diagnosis of a fetus with Down syndrome. Although the race-based formula increased sensitivity in each population, the increase was statistically significant only in the white population, whereas a decrease in specificity was statistically significant in all 4 populations, as denoted by nonoverlapping confidence intervals. The area under the receiver operating characteristic curve for the model using the race-specific definition of short femur length was 0.67 versus 0.65 compared with the standard definition, and for humerus length it was 0.70 versus 0.71. The use of race-based formulas for the determination of short femur and humerus lengths did not significantly improve the detection rates for Down syndrome.
Phillips, Donna; Egol, Kenneth A; Maculatis, Martine C; Roloff, Kathryn S; Friedman, Alan M; Levine, Brett; Garfin, Steven; Schwartz, Alexandra; Sterling, Robert; Kuivila, Thomas; Paragioudakis, Steve J; Zuckerman, Joseph D
To understand the personality factors associated with orthopedic surgery resident performance. A prospective, cross-sectional survey of orthopedic surgery faculty that assessed their perceptions of the personality traits most highly associated with resident performance. Residents also completed a survey to determine their specific personality characteristics. A subset of faculty members rated the performance of those residents within their respective program on 5 dimensions. Multiple regression models tested the relationship between the set of resident personality measures and each aspect of performance; relative weights analyses were then performed to quantify the contribution of the individual personality measures to the total variance explained in each performance domain. Independent samples t-tests were conducted to examine differences between the personality characteristics of residents and those faculty identified as relevant to successful resident performance. Data were collected from 12 orthopedic surgery residency programs 1 throughout the United States. The level of clinical care provided by participating institutions varied. Data from 175 faculty members and 266 residents across 12 programs were analyzed. The personality features of residents were related to faculty evaluations of resident performance (for all, p < 0.01); the full set of personality measures accounted for 4%-11% of the variance in ratings of resident performance. Particularly, the characteristics of agreeableness, neuroticism, and learning approach were found to be most important for explaining resident performance. Additionally, there were significant differences between the personality features that faculty members identified as important for resident performance and the personality features that residents possessed. Personality assessments can predict orthopedic surgery resident performance. However, results suggest the traits that faculty members value or reward among residents could be different from the traits associated with improved resident performance. Copyright © 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Study of the true performance limits of the Astrometric Multiplexing Area Scanner (AMAS)
NASA Technical Reports Server (NTRS)
Frederick, L. W.; Mcalister, H. A.
1975-01-01
The Astrometric Multiplexing Area Scanner (AMAS) is an instrument designed to perform photoelectric long focus astrometry of small fields. Modulation of a telescope focal plane with a rotating Ronchi ruling produces a frequency modulated signal from which relative positions and magnitudes can be extracted. Evaluation instrumental precision, accuracy and resolution characteristics with respect to a variety of instrumental and cosmical parameters indicates 1.5 micron precision and accuracy for single stars under specific conditions. This value decreases for increased number of field stars, particularly for fainter stars.
Woven TPS Mechanical Property Evaluation
NASA Technical Reports Server (NTRS)
Gonzales, Gregory Lewis; Kao, David Jan-Woei; Stackpoole, Margaret M.
2013-01-01
Woven Thermal Protection Systems (WTPS) is a relatively new program funded by the Office of the Chief Technologist (OCT). The WTPS approach to producing TPS architectures uses precisely engineered 3-D weaving techniques that allow tailoring material characteristics needed to meet specific mission requirements. A series of mechanical tests were performed to evaluate performance of different weave types, and get a better understanding of failure modes expected in these three-dimensional architectures. These properties will aid in material down selection and guide selection of the appropriate WTPS for a potential mission.
Diversity Order Analysis of Dual-Hop Relaying with Partial Relay Selection
NASA Astrophysics Data System (ADS)
Bao, Vo Nguyen Quoc; Kong, Hyung Yun
In this paper, we study the performance of dual hop relaying in which the best relay selected by partial relay selection will help the source-destination link to overcome the channel impairment. Specifically, closed-form expressions for outage probability, symbol error probability and achievable diversity gain are derived using the statistical characteristic of the signal-to-noise ratio. Numerical investigation shows that the system achieves diversity of two regardless of relay number and also confirms the correctness of the analytical results. Furthermore, the performance loss due to partial relay selection is investigated.
Artificial Neural Networks Equivalent to Fuzzy Algebra T-Norm Conjunction Operators
NASA Astrophysics Data System (ADS)
Iliadis, L. S.; Spartalis, S. I.
2007-12-01
This paper describes the construction of three Artificial Neural Networks with fuzzy input and output, imitating the performance of fuzzy algebra conjunction operators. More specifically, it is applied over the results of a previous research effort that used T-Norms in order to produce a characteristic torrential risk index that unified the partial risk indices for the area of Xanthi. Each one of the three networks substitutes a T-Norm and consequently they can be used as equivalent operators. This means that ANN performing Fuzzy Algebra operations can be designed and developed.
Geometry and gravity influences on strength capability
NASA Technical Reports Server (NTRS)
Poliner, Jeffrey; Wilmington, Robert P.; Klute, Glenn K.
1994-01-01
Strength, defined as the capability of an individual to produce an external force, is one of the most important determining characteristics of human performance. Knowledge of strength capabilities of a group of individuals can be applied to designing equipment and workplaces, planning procedures and tasks, and training individuals. In the manned space program, with the high risk and cost associated with spaceflight, information pertaining to human performance is important to ensuring mission success and safety. Knowledge of individual's strength capabilities in weightlessness is of interest within many areas of NASA, including workplace design, tool development, and mission planning. The weightless environment of space places the human body in a completely different context. Astronauts perform a variety of manual tasks while in orbit. Their ability to perform these tasks is partly determined by their strength capability as demanded by that particular task. Thus, an important step in task planning, development, and evaluation is to determine the ability of the humans performing it. This can be accomplished by utilizing quantitative techniques to develop a database of human strength capabilities in weightlessness. Furthermore, if strength characteristics are known, equipment and tools can be built to optimize the operators' performance. This study examined strength in performing a simple task, specifically, using a tool to apply a torque to a fixture.
Experimental framework to study tip vortex interactions in multirotor wakes
NASA Astrophysics Data System (ADS)
Yao, Rongnan; Araya, Daniel
2017-11-01
We present an experimental study to compare the dynamic characteristics of tip vortices shed from a propeller in a crossflow to similar characteristics of an isolated vortex column generated in a closed system. Our aim is to evaluate the feasibility of using this simple isolated system to study the more complicated three-dimensional vortex interactions inherent to multirotor wakes, where the local unsteadiness generated by one rotor can strongly impact the performance of nearby rotors. Time-resolved particle image velocimetry is used to measure the velocity field of the propeller wake flow in a wind tunnel and the vortex column in a water tank. Specific attention is placed on analyzing the observed vortex core precession in the isolated system and comparing this to characteristic tip-vortex wandering phenomenon.
Systemic sclerosis: a world wide global analysis.
Coral-Alvarado, Paola; Pardo, Aryce L; Castaño-Rodriguez, Natalia; Rojas-Villarraga, Adriana; Anaya, Juan-Manuel
2009-07-01
The objective of this study was to analyze epidemiological tendencies of systemic sclerosis (SSc) around the world in order to identify possible local variations in the presentation and occurrence of the disease. A systematic review of the literature was performed through electronic databases using the keywords "Systemic Sclerosis" and "Clinical Characteristics." Out of a total of 167 articles, 41 were included in the analysis. Significant differences in the mean age at the time of diagnosis, subsets of SSc, clinical characteristics, and presence of antibodies were found between different regions of the word. Because variations in both additive and nonadditive genetic factors and the environmental variance are specific to the investigated population, ethnicity and geography are important characteristics to be considered in the study of SSc and other autoimmune diseases.
Transformational leadership and employee safety performance: a within-person, between-jobs design.
Inness, Michelle; Turner, Nick; Barling, Julian; Stride, Chris B
2010-07-01
We investigated the extent to which the safety performance (i.e., self-reported safety compliance and safety participation) of employees with 2 jobs was predicted by their respective supervisors' transformational leadership behaviors. We compared 2 within-person models: a context-specific model (i.e., transformational leadership experienced by employees in 1 context related to those same employees' safety performance only in that context) and a context-spillover model (i.e., transformational leadership experienced by employees in 1 context related to those same employees' safety performance in the same and other contexts). Our sample comprised 159 "moonlighters" (73 men, 86 women): employees who simultaneously hold 2 different jobs, each with a different supervisor, providing within-person data on the influence of different supervisors on employee safety performance across 2 job contexts. Having controlled for individual differences (negative affectivity and conscientiousness) and work characteristics (e.g., hours worked and length of relationship with supervisor), the context-specific model provided the best fit to the data among alternative nested models. Implications for the role of transformational leadership in promoting workplace safety are discussed.
Bencke, J; Damsgaard, R; Saekmose, A; Jørgensen, P; Jørgensen, K; Klausen, K
2002-06-01
The aim of the present investigation was to study the possible effects of specificity of training on muscle strength and anaerobic power in children from different sports and at different performance levels in relation to growth and maturation status. Hundred and eighty-four children of both gender participating either in swimming, tennis, team handball or gymnastics were recruited from the best clubs in Denmark. Within each sport, the coach had divided the children into an elite (E) and non-elite (NE) group according to performance level and talent. Tanner stage assessment and body weight and height measurements were performed by a physician. The anaerobic performances were assessed by Wingate tests and jumping performance in squat jump (SJ), countermovement jump (CMJ) and drop jump (DJ) from two heights. Most of the differences between groups in Wingate performance disappeared when the data were normalised to body mass. The gymnasts were the best jumpers and their superiority were increased in the more complex motor coordination tasks like DJ. The results may indicate some influence of training specificity, especially on the more complex motor tasks as DJ and there may be an effect of training before puberty. The performance in the less complex motor tasks like cycling and SJ and CMJ may also be influenced by specific training, but not to the same extent, and heritance may be an important factor for performance in these anaerobic tasks.
Genetic Mapping of Fixed Phenotypes: Disease Frequency as a Breed Characteristic
Jones, Paul; Martin, Alan; Ostrander, Elaine A.; Lark, Karl G.
2009-01-01
Traits that have been stringently selected to conform to specific criteria in a closed population are phenotypic stereotypes. In dogs, Canis familiaris, such stereotypes have been produced by breeding for conformation, performance (behaviors), etc. We measured phenotypes on a representative sample to establish breed stereotypes. DNA samples from 147 dog breeds were used to characterize single nucleotide polymorphism allele frequencies for association mapping of breed stereotypes. We identified significant size loci (quantitative trait loci [QTLs]), implicating candidate genes appropriate to regulation of size (e.g., IGF1, IGF2BP2 SMAD2, etc.). Analysis of other morphological stereotypes, also under extreme selection, identified many additional significant loci. Behavioral loci for herding, pointing, and boldness implicated candidate genes appropriate to behavior (e.g., MC2R, DRD1, and PCDH9). Significant loci for longevity, a breed characteristic inversely correlated with breed size, were identified. The power of this approach to identify loci regulating the incidence of specific polygenic diseases is demonstrated by the association of a specific IGF1 haplotype with hip dysplasia, patella luxation, and pacreatitis. PMID:19321632
Allergen Sensitization Pattern by Sex: A Cluster Analysis in Korea.
Ohn, Jungyoon; Paik, Seung Hwan; Doh, Eun Jin; Park, Hyun-Sun; Yoon, Hyun-Sun; Cho, Soyun
2017-12-01
Allergens tend to sensitize simultaneously. Etiology of this phenomenon has been suggested to be allergen cross-reactivity or concurrent exposure. However, little is known about specific allergen sensitization patterns. To investigate the allergen sensitization characteristics according to gender. Multiple allergen simultaneous test (MAST) is widely used as a screening tool for detecting allergen sensitization in dermatologic clinics. We retrospectively reviewed the medical records of patients with MAST results between 2008 and 2014 in our Department of Dermatology. A cluster analysis was performed to elucidate the allergen-specific immunoglobulin (Ig)E cluster pattern. The results of MAST (39 allergen-specific IgEs) from 4,360 cases were analyzed. By cluster analysis, 39items were grouped into 8 clusters. Each cluster had characteristic features. When compared with female, the male group tended to be sensitized more frequently to all tested allergens, except for fungus allergens cluster. The cluster and comparative analysis results demonstrate that the allergen sensitization is clustered, manifesting allergen similarity or co-exposure. Only the fungus cluster allergens tend to sensitize female group more frequently than male group.
Hellier, Paul; Purton, Saul; Ladommatos, Nicos
2015-01-01
The metabolic engineering of photosynthetic microbes for production of novel hydrocarbons presents an opportunity for development of advanced designer biofuels. These can be significantly more sustainable, throughout the production-to-consumption lifecycle, than the fossil fuels and crop-based biofuels they might replace. Current biofuels, such as bioethanol and fatty acid methyl esters, have been developed primarily as drop-in replacements for existing fossil fuels, based on their physical properties and autoignition characteristics under specific combustion regimes. However, advances in the genetic engineering of microalgae and cyanobacteria, and the application of synthetic biology approaches offer the potential of designer strains capable of producing hydrocarbons and oxygenates with specific molecular structures. Furthermore, these fuel molecules can be designed for higher efficiency of energy release and lower exhaust emissions during combustion. This paper presents a review of potential fuel molecules from photosynthetic microbes and the performance of these possible fuels in modern internal combustion engines, highlighting which modifications to the molecular structure of such fuels may enhance their suitability for specific combustion regimes. PMID:25941673
Hellier, Paul; Purton, Saul; Ladommatos, Nicos
2015-01-01
The metabolic engineering of photosynthetic microbes for production of novel hydrocarbons presents an opportunity for development of advanced designer biofuels. These can be significantly more sustainable, throughout the production-to-consumption lifecycle, than the fossil fuels and crop-based biofuels they might replace. Current biofuels, such as bioethanol and fatty acid methyl esters, have been developed primarily as drop-in replacements for existing fossil fuels, based on their physical properties and autoignition characteristics under specific combustion regimes. However, advances in the genetic engineering of microalgae and cyanobacteria, and the application of synthetic biology approaches offer the potential of designer strains capable of producing hydrocarbons and oxygenates with specific molecular structures. Furthermore, these fuel molecules can be designed for higher efficiency of energy release and lower exhaust emissions during combustion. This paper presents a review of potential fuel molecules from photosynthetic microbes and the performance of these possible fuels in modern internal combustion engines, highlighting which modifications to the molecular structure of such fuels may enhance their suitability for specific combustion regimes.
Genetic mapping of fixed phenotypes: disease frequency as a breed characteristic.
Chase, Kevin; Jones, Paul; Martin, Alan; Ostrander, Elaine A; Lark, Karl G
2009-01-01
Traits that have been stringently selected to conform to specific criteria in a closed population are phenotypic stereotypes. In dogs, Canis familiaris, such stereotypes have been produced by breeding for conformation, performance (behaviors), etc. We measured phenotypes on a representative sample to establish breed stereotypes. DNA samples from 147 dog breeds were used to characterize single nucleotide polymorphism allele frequencies for association mapping of breed stereotypes. We identified significant size loci (quantitative trait loci [QTLs]), implicating candidate genes appropriate to regulation of size (e.g., IGF1, IGF2BP2 SMAD2, etc.). Analysis of other morphological stereotypes, also under extreme selection, identified many additional significant loci. Behavioral loci for herding, pointing, and boldness implicated candidate genes appropriate to behavior (e.g., MC2R, DRD1, and PCDH9). Significant loci for longevity, a breed characteristic inversely correlated with breed size, were identified. The power of this approach to identify loci regulating the incidence of specific polygenic diseases is demonstrated by the association of a specific IGF1 haplotype with hip dysplasia, patella luxation, and pancreatitis.
An operational satellite scatterometer for wind vector measurements over the ocean
NASA Technical Reports Server (NTRS)
Grantham, W. L.; Bracalente, E. M.; Jones, W. L.; Schrader, J. H.; Schroeder, L. C.; Mitchell, J. L.
1975-01-01
Performance requirements and design characteristics of a microwave scatterometer wind sensor for measuring surface winds over the oceans on a global basis are described. Scatterometer specifications are developed from user requirements of wind vector measurement range and accuracy, swath width, resolution cell size and measurement grid spacing. A detailed analysis is performed for a baseline fan-beam scatterometer design, and its performance capabilities for meeting the SeaSat-A user requirements. Various modes of operation are discussed which will allow the resolution of questions concerning the effects of sea state on the scatterometer wind sensing ability and to verify design boundaries of the instrument.
Characterization and evaluation of an aeolian-photovoltaic system in operation
NASA Astrophysics Data System (ADS)
Bonfatti, F.; Calzolari, P. U.; Cardinali, G. C.; Vivanti, G.; Zani, A.
Data management, analysis techniques and results of performance monitoring of a prototype combined photovoltaic (PV)-wind turbine farm power plant in northern Italy are reported. Emphasis is placed on the PV I-V characteristics and irradiance and cell temperatures. Automated instrumentation monitors and records meteorological data and generator variables such as voltages, currents, output, battery electrolyte temperature, etc. Analysis proceeds by automated selection of I-V data for specific intervals of the year when other variables can be treated as constants. The technique permits characterization of generator performance, adjusting the power plant set points for optimal output, and tracking performance degradation over time.
Nuclear thermal rocket nozzle testing and evaluation program
NASA Technical Reports Server (NTRS)
Davidian, Kenneth O.; Kacynski, Kenneth J.
1993-01-01
Performance characteristics of the Nuclear Thermal Rocket can be enhanced through the use of unconventional nozzles as part of the propulsion system. The Nuclear Thermal Rocket nozzle testing and evaluation program being conducted at the NASA Lewis is outlined and the advantages of a plug nozzle are described. A facility description, experimental designs and schematics are given. Results of pretest performance analyses show that high nozzle performance can be attained despite substantial nozzle length reduction through the use of plug nozzles as compared to a convergent-divergent nozzle. Pretest measurement uncertainty analyses indicate that specific impulse values are expected to be within + or - 1.17 pct.
An in-depth review of photovoltaic system performance models
NASA Technical Reports Server (NTRS)
Smith, J. H.; Reiter, L. R.
1984-01-01
The features, strong points and shortcomings of 10 numerical models commonly applied to assessing photovoltaic performance are discussed. The models range in capabilities from first-order approximations to full circuit level descriptions. Account is taken, at times, of the cell and module characteristics, the orientation and geometry, array-level factors, the power-conditioning equipment, the overall plant performance, O and M effects, and site-specific factors. Areas of improvement and/or necessary extensions are identified for several of the models. Although the simplicity of a model was found not necessarily to affect the accuracy of the data generated, the use of any one model was dependent on the application.
Technical, analytical and computer support
NASA Technical Reports Server (NTRS)
1972-01-01
The development of a rigorous mathematical model for the design and performance analysis of cylindrical silicon-germanium thermoelectric generators is reported that consists of two parts, a steady-state (static) and a transient (dynamic) part. The material study task involves the definition and implementation of a material study that aims to experimentally characterize the long term behavior of the thermoelectric properties of silicon-germanium alloys as a function of temperature. Analytical and experimental efforts are aimed at the determination of the sublimation characteristics of silicon germanium alloys and the study of sublimation effects on RTG performance. Studies are also performed on a variety of specific topics on thermoelectric energy conversion.
NASA Technical Reports Server (NTRS)
1975-01-01
A program was conducted which included the design of a set of simplified simulation tasks, design of apparatus and breadboard TV equipment for task performance, and the implementation of a number of simulation tests. Performance measurements were made under controlled conditions and the results analyzed to permit evaluation of the relative merits (effectivity) of various TV systems. Burden factors were subsequently generated for each TV system to permit tradeoff evaluation of system characteristics against performance. For the general remote operation mission, the 2-view system is recommended. This system is characterized and the corresponding equipment specifications were generated.
Jackson, Linda A; Samona, Ricky; Moomaw, Jeff; Ramsay, Lauren; Murray, Christopher; Smith, Amy; Murray, Lindsay
2007-04-01
HomeNetToo is a longitudinal field study designed to examine the antecedents and consequences of home Internet use in low-income families. Participants included 140 children, mostly 13-year-old African American (83%) boys (58%), living in single-parent households (75%) where the median annual income was $15,000 (USD). This report focuses on children's Internet activities, socio-demographic characteristics related to their Internet activities, and the relationship between academic performance and Internet activities. Overall, findings indicate that low-income children initially use the Internet primarily for entertainment. As home Internet use loses its novelty children become more focused in their Internet activities, reducing the number of websites they visit and visiting more websites targeted to their specific interests. Pornography websites are popular initially, especially among boys, but their popularity decreases dramatically after 3 months. Age, race, and sex have little influence on which websites are most popular. Academic performance predicts subsequent Internet activities, and Internet activities predict subsequent academic performance. Directions for future research to identify mechanisms that mediate the relationship between Internet activities and academic performance and implications for the digital divide are discussed.
A case study in nonconformance and performance trend analysis
NASA Technical Reports Server (NTRS)
Maloy, Joseph E.; Newton, Coy P.
1990-01-01
As part of NASA's effort to develop an agency-wide approach to trend analysis, a pilot nonconformance and performance trending analysis study was conducted on the Space Shuttle auxiliary power unit (APU). The purpose of the study was to (1) demonstrate that nonconformance analysis can be used to identify repeating failures of a specific item (and the associated failure modes and causes) and (2) determine whether performance parameters could be analyzed and monitored to provide an indication of component or system degradation prior to failure. The nonconformance analysis of the APU did identify repeating component failures, which possibly could be reduced if key performance parameters were monitored and analyzed. The performance-trending analysis verified that the characteristics of hardware parameters can be effective in detecting degradation of hardware performance prior to failure.
Imaging-based logics for ornamental stone quality chart definition
NASA Astrophysics Data System (ADS)
Bonifazi, Giuseppe; Gargiulo, Aldo; Serranti, Silvia; Raspi, Costantino
2007-02-01
Ornamental stone products are commercially classified on the market according to several factors related both to intrinsic lythologic characteristics and to their visible pictorial attributes. Sometimes these latter aspects prevail in quality criteria definition and assessment. Pictorial attributes are in any case also influenced by the performed working actions and the utilized tools selected to realize the final stone manufactured product. Stone surface finishing is a critical task because it can contribute to enhance certain aesthetic features of the stone itself. The study was addressed to develop an innovative set of methodologies and techniques able to quantify the aesthetic quality level of stone products taking into account both the physical and the aesthetical characteristics of the stones. In particular, the degree of polishing of the stone surfaces and the presence of defects have been evaluated, applying digital image processing strategies. Morphological and color parameters have been extracted developing specific software architectures. Results showed as the proposed approaches allow to quantify the degree of polishing and to identify surface defects related to the intrinsic characteristics of the stone and/or the performed working actions.
The application of active side arm controllers in helicopters
NASA Technical Reports Server (NTRS)
Knorr, R.; Melz, C.; Faulkner, A.; Obermayer, M.
1993-01-01
Eurocopter Deutschland (ECD) started simulation trials to investigate the particular problems of Side Arm Controllers (SAC) applied to helicopters. Two simulation trials have been performed. In the first trial, the handling characteristics of a 'passive' SAC and the basic requirements for the application of an 'active' SAC were evaluated in pilot-in-the-loop simulations, performing the tasks in a realistic scenario representing typical phases of a transport mission. The second simulation trial investigated the general control characteristics of the 'active' in comparison to the 'passive' control principle. A description of the SACs developed by ECD and the principle of the 'passive' and 'active' control concept is given, as well as specific ratings for the investigated dynamic and ergonomic parameters effecting SAC characteristics. The experimental arrangements, as well as the trials procedures of both simulation phases, are described and the results achieved are discussed emphasizing the advantages of the 'active' as opposed to the 'passive' SAC concept. This also includes the presentation of some critical aspects still to be improved and proposals to solve them.
CLINICAL DEMOGRAPHIC CHARACTERISTICS OF TOTAL KNEE ARTHROPLASTY IN A UNIVERSITY HOSPITAL
Souza, José Miguel Francisco da Silva; Ferreira, Ricardo dos Santos; de Lima, Alexandre José Pereira; de Sá, Airton César Pereira; de Albuquerque, Paulo Cezar Vidal Carneiro
2016-01-01
ABSTRACT Objective: To assess socio-demographic characteristics of patients undergoing total knee arthroplasty (TKA) in a public university hospital, evaluating the outcome infection and associated factors. Method: A retrospective study was carried out with 78 patients undergoing TKA, from 2013 to 2014. The socio-demographic and clinical characteristics of the patients were collected. Comparison between infected and non-infected patients was performed to find out which variables were possibly associated to this complication. Result: Of 81 arthroplasties performed, patients were older (mean age 64 years), women (79%), with primary osteoarthritis as main etiology (87.6%) and most had comorbidities (82.7%). Infection occurred in 16% of patients, and this outcome associated with age older than 65 years (p=0.023) and the occurrence of deep vein thrombosis (p=0.027). Conclusion: Patients undergoing TKA are mostly elderly women with primary osteoarthritis in the knee and comorbidities who developed infection in 16% of cases. More studies need to be conducted aimed at creating specific protocols in order to improve the quality of clinical practice. Level of Evidence III, Retrospective Comparative Study. PMID:28924354
Melhem, N; El Balaa, H; Younes, G; Al Kattar, Z
2017-06-15
The Secondary Standard Dosimetry Laboratory at the Lebanese Atomic Energy Commission has different calibration methods for various types of dosimeters used in industrial, military and medical fields. The calibration is performed using different beams of X-rays (low and medium energy) and Gamma radiation delivered by a Cesium 137 source. The Secondary Standard Dosimetry laboratory in charge of calibration services uses different protocols for the determination of high and low air kerma rate and for narrow and wide series. In order to perform this calibration work, it is very important to identify all the beam characteristics for the different types of sources and qualities of radiation. The following work describes the methods used for the determination of different beam characteristics and calibration coefficients with their uncertainties in order to enhance the radiation protection of workers and patient applications in the fields of medical diagnosis and industrial X-ray. All the characteristics of the X-ray beams are determined for the narrow spectrum series in the 40 and 200 keV range where the inherent filtration, the current intensity, the high voltage, the beam profile and the total uncertainty are the specific characteristics of these X-ray beams. An X-ray software was developed in order to visualize the reference values according to the characteristics of each beam. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
On the interpolation of light-scattering responses from irregularly shaped particles
NASA Astrophysics Data System (ADS)
Videen, Gorden; Zubko, Evgenij; Arnold, Jessica A.; MacCall, Benjamin; Weinberger, Alycia J.; Shkuratov, Yuriy; Muñoz, Olga
2018-05-01
Common particle characteristics needed for many applications may include size, eccentricity, porosity and refractive index. Determining such characteristics from scattered light is a primary goal of remote sensing. For other applications, like differentiating a hazardous particle from the natural background, information about higher fidelity particle characteristics may be required, including specific shape or chemical composition. While a complete characterization of a particle system from its scattered light through the inversion process remains unachievable, great strides have been made in providing information in the form of constraints on particle characteristics. Recent advances have been made in quantifying the characteristics of polydispersions of irregularly shaped particles by making comparisons of the light-scattering signals from model simulant particles. We show that when the refractive index is changed, the light-scattering characteristics from polydispersions of such particles behave monotonically over relatively large parameter ranges compared with those of monodisperse distributions of particles having regular shapes, like spheres, spheroids, etc. This allows for their properties to be interpolated, which results in a significant reduction of the computational load when performing inversions.
NASA Technical Reports Server (NTRS)
Kamhawi, Hani; Huang, Wensheng; Haag, Thomas; Spektor, Rostislav
2014-01-01
The National Aeronautics and Space Administration (NASA) Science Mission Directorate In-Space Propulsion Technology office is sponsoring NASA Glenn Research Center to develop a 4 kW-class Hall thruster propulsion system for implementation in NASA science missions. A study was conducted to assess the impact of varying the facility background pressure on the High Voltage Hall Accelerator (HiVHAc) thruster performance and voltage-current characteristics. This present study evaluated the HiVHAc thruster performance in the lowest attainable background pressure condition at NASA GRC Vacuum Facility 5 to best simulate space-like conditions. Additional tests were performed at selected thruster operating conditions to investigate and elucidate the underlying physics that change during thruster operation at elevated facility background pressure. Tests were performed at background pressure conditions that are three and ten times higher than the lowest realized background pressure. Results indicated that the thruster discharge specific impulse and efficiency increased with elevated facility background pressure. The voltage-current profiles indicated a narrower stable operating region with increased background pressure. Experimental observations of the thruster operation indicated that increasing the facility background pressure shifted the ionization and acceleration zones upstream towards the thrusters anode. Future tests of the HiVHAc thruster are planned at background pressure conditions that are expected to be two to three times lower than what was achieved during this test campaign. These tests will not only assess the impact of reduced facility background pressure on thruster performance, voltage-current characteristics, and plume properties; but will also attempt to quantify the magnitude of the ionization.
NASA Technical Reports Server (NTRS)
Anderson, R. A.; Arnold, D. B.; Johnson, G. A.
1979-01-01
A NASA-funded program is described which aims to develop a resin system for use in the construction of lavatory wall panels, sidewall panels, and ceiling panels possessing flammability, smoke and gas emission, and toxicity (FS&T) characteristics superior to the existing epoxy resin. Candidate resins studied were phenolic, polyimide, and bismaleimide. Based on the results of a series of FS&T as well as mechanical and aesthetic property tests, a phenolic resin was chosen as the superior material. Material and process specifications covering the phenolic resin based materials were prepared and a method of rating sandwich panel performance was developed.
NASA Technical Reports Server (NTRS)
Pauckert, R. P.
1974-01-01
The performance and heat transfer characteristics of a doublet element type injector for the space shuttle orbiter maneuvering engine thrust chamber were investigated. Ths stability characteristics were evaluated over a range of chamber pressures and mixture ratios. The specific objectives of the test were: (1) to determine whether stability has been influenced by injection of boundary layer coolant across the cavity entrance, (2) if the injector is stable, to determine the minimum cavity area required to maintain stability, and (3) if the injector is unstable, to determine the effects of entrance geometry and increased area on stability.
Control of a 30 cm diameter mercury bombardment thruster
NASA Technical Reports Server (NTRS)
Terdan, F. F.; Bechtel, R. T.
1973-01-01
Increased thruster performance has made closed-loop automatic control more difficult than previously. Specifically, high perveance optics tend to make reliable recycling more difficult. Control logic functions were established for three automatic modes of operation of a 30-cm thruster using a power conditioner console with flight-like characteristics. The three modes provide (1) automatic startup to reach thermal stability, (2) steady-state closed-loop control, and (3) the reliable recycling of the high voltages following an arc breakdown to reestablish normal operation. Power supply impedance characteristics necessary for stable operation and the effect of the magnetic baffle on the reliable recycling was studied.
Yo, Chia-Hung; Lee, Si-Huei; Chang, Shy-Shin; Lee, Matthew Chien-Hung; Lee, Chien-Chang
2014-01-01
Objectives We performed a systematic review and meta-analysis of studies on high-sensitivity C-reactive protein (hs-CRP) assays to see whether these tests are predictive of atrial fibrillation (AF) recurrence after cardioversion. Design Systematic review and meta-analysis. Data sources PubMed, EMBASE and Cochrane databases as well as a hand search of the reference lists in the retrieved articles from inception to December 2013. Study eligibility criteria This review selected observational studies in which the measurements of serum CRP were used to predict AF recurrence. An hs-CRP assay was defined as any CRP test capable of measuring serum CRP to below 0.6 mg/dL. Primary and secondary outcome measures We summarised test performance characteristics with the use of forest plots, hierarchical summary receiver operating characteristic curves and bivariate random effects models. Meta-regression analysis was performed to explore the source of heterogeneity. Results We included nine qualifying studies comprising a total of 347 patients with AF recurrence and 335 controls. A CRP level higher than the optimal cut-off point was an independent predictor of AF recurrence after cardioversion (summary adjusted OR: 3.33; 95% CI 2.10 to 5.28). The estimated pooled sensitivity and specificity for hs-CRP was 71.0% (95% CI 63% to 78%) and 72.0% (61% to 81%), respectively. Most studies used a CRP cut-off point of 1.9 mg/L to predict long-term AF recurrence (77% sensitivity, 65% specificity), and 3 mg/L to predict short-term AF recurrence (73% sensitivity, 71% specificity). Conclusions hs-CRP assays are moderately accurate in predicting AF recurrence after successful cardioversion. PMID:24556243
Wan, Bing; Wang, Siqi; Tu, Mengqi; Wu, Bo; Han, Ping; Xu, Haibo
2017-03-01
The purpose of this meta-analysis was to evaluate the diagnostic accuracy of perfusion magnetic resonance imaging (MRI) as a method for differentiating glioma recurrence from pseudoprogression. The PubMed, Embase, Cochrane Library, and Chinese Biomedical databases were searched comprehensively for relevant studies up to August 3, 2016 according to specific inclusion and exclusion criteria. The quality of the included studies was assessed according to the quality assessment of diagnostic accuracy studies (QUADAS-2). After performing heterogeneity and threshold effect tests, pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were calculated. Publication bias was evaluated visually by a funnel plot and quantitatively using Deek funnel plot asymmetry test. The area under the summary receiver operating characteristic curve was calculated to demonstrate the diagnostic performance of perfusion MRI. Eleven studies covering 416 patients and 418 lesions were included in this meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 0.88 (95% confidence interval [CI] 0.84-0.92), 0.77 (95% CI 0.69-0.84), 3.93 (95% CI 2.83-5.46), 0.16 (95% CI 0.11-0.22), and 27.17 (95% CI 14.96-49.35), respectively. The area under the summary receiver operating characteristic curve was 0.8899. There was no notable publication bias. Sensitivity analysis showed that the meta-analysis results were stable and credible. While perfusion MRI is not the ideal diagnostic method for differentiating glioma recurrence from pseudoprogression, it could improve diagnostic accuracy. Therefore, further research on combining perfusion MRI with other imaging modalities is warranted.
Restoration of soils affected by oil exploitation activities based in functional diversity studies
NASA Astrophysics Data System (ADS)
Villacis, Jaime; Casanoves, Fernando; Hang, Susana; Armas, Cristina
2017-04-01
The functional characteristics of 25 forest species used in the restoration of areas affected by oil extraction activities were determined and species functional groups were constructed. Subsequently, the functional characteristics of the groups were related with performance variables of the species obtained in complementary studies, to make use recommendations. Three functional groups of species with similar responses and / or performance were characterized that showed significant differences between them for quantitative and qualitative traits. The first group formed by all shrubs and the rest of trees, most do not fix nitrogen, have single leaves and all species are evergreen and characterized by having lower values of specific foliar area, foliar nitrogen, dry matter leaf content and wood density, was denominated as intermediate acquisitions. The second group composed only for trees that do not fix nitrogen and with deciduous leaves and characterized by having the highest values of dry matter leaf content and foliar tensile force and intermediate values of specific foliar area and foliar nitrogen, was denominated as low conservative. Finally the third group formed only by trees that fix nitrogen, composed of leaves and mostly evergreen and characterized by having higher values of specific foliar area, foliar nitrogen, foliar phosphorus and lower foliar tensile force, was denominated as acquisitive. The intermediary acquisitions species Apeiba membranacea, Myrcia aff. fallax and Zygia longifolia, and the acquisitive species Cedrelinga cateniformis, Inga densiflora, Myroxylon balsamum, Piptadenia pteroclada and Platymiscium pinnatum, which showed excellent performance in nursery and / or field, represent the most suitable species to be used in reforestation programs of the sites affected by oil extraction activities in the Amazon region of Ecuador, because they have greater potential to protect soil and recycle nutrients in the initial stages of planting.
The issue of applying marketing on the pharmaceutical market in Serbia.
Dickov, V; Dickov, A; Martinović-Mitrović, S
2011-03-01
The issue of applying marketing on the pharmaceutical market has the features of subject-based approach, with the intention to appreciate the specific nature of the products, as well as the special characteristics of the complexly formed demand. The relevance of the issue is related to the above-average performance of the pharmaceutical industry, its role in the generation of humanity's demographic transition, and specific development routes of marketing as a scientific and practical discipline. The sensitive nature of a pharmaceutical product on the one hand generates the intense legislation on this market, whereas on the other, the circumstances of its use generate a specific environment in which the production/consumption of the products of pharmaceutical industry is intensively reflected as a specific medical, cultural, economic and even political phenomenon.
Moon, Chan Hong; Fukuda, Mitsuhiro; Kim, Seong-Gi
2012-01-01
The neural specificity of hemodynamic-based functional magnetic resonance imaging (fMRI) signals are dependent on both the vascular regulation and the sensitivity of the applied fMRI technique to different types and sizes of blood vessels. In order to examine the specificity of MRI-detectable hemodynamic responses, submillimeter blood oxygenation-level dependent (BOLD) and cerebral blood volume (CBV) fMRI studies were performed in a well-established cat orientation column model at 9.4 Tesla. Neural-nonspecific and -specific signals were separated by comparing the fMRI responses of orthogonal orientation stimuli. The BOLD response was dominantly neural-nonspecific, mostly originating from pial and intracortical emerging veins, and thus was highly correlated with baseline blood volume. Uneven baseline CBV may displace or distort small functional domains in high-resolution BOLD maps. The CBV response in the parenchyma exhibited dual spatiotemporal characteristics, a fast and early neural-nonspecific response (with 4.3-s time constant) and a slightly slower and delayed neural-specific response (with 9.4-s time constant). The nonspecific CBV signal originates from early-responding arteries and arterioles, while the specific CBV response, which is not correlated with baseline blood volume, arises from late-responding microvessels including small pre-capillary arterioles and capillaries. Our data indicate that although the neural specificity of CBV fMRI signals is dependent on stimulation duration, high-resolution functional maps can be obtained from steady-state CBV studies. PMID:22960251
Evaluation program for secondary spacecraft cells
NASA Technical Reports Server (NTRS)
Christy, D. E.
1972-01-01
The life cycle test of secondary spacecraft electric cells is discussed. The purpose of the tests is to insure that all cells put into the life cycle test meet the required specifications. The evaluation program gathers statistical information concerning cell performance characteristics and limitations. Weaknesses in cell design which are discovered during the tests are reported to research facilities in order to increase the service life of the cells.
ERIC Educational Resources Information Center
REECE, WILLIAM K.
TO EVALUATE THE EFFECTIVENESS OF A KINDERGARTEN PROGRAM OF SPECIFIC TRAINING RELATED TO MOTOR, SENSORY, AND PERCEPTUAL (M-S-P) PERFORMANCE, AN INSTRUMENT WAS DEVISED TO MEASURE THE M-S-P NEEDS AND STRENGTHS OF INDIVIDUAL PUPILS. RESEARCH WAS CONDUCTED TO TEST THE DIAGNOSTIC AND PREDICTIVE POTENTIALS OF THE M-S-P INSTRUMENT AND TO ASCERTAIN THE…
Amplifiers in the radio-electronic equipment of aircraft
NASA Astrophysics Data System (ADS)
Khol'Nyi, Vladimir Ia.
The applications, classification, and technical specifications of airborne electronic amplifiers are discussed. Particular attention is given to the general design and principles of operation of single amplification cascades and multicascade amplifiers, including dc, audio, and video amplifiers used as part of the radio-electronic equipment of modern aircraft. The discussion also covers the principal technical and performance characteristics of various amplifiers, their operating conditions, service, and repair.
Charge-coupled device image sensor study
NASA Technical Reports Server (NTRS)
1973-01-01
The design specifications and predicted performance characteristics of a Charge-Coupled Device Area Imager and a Charge-Coupled Device Linear Imager are presented. The Imagers recommended are intended for use in space-borne imaging systems and therefore would meet the requirements for the intended application. A unique overlapping metal electrode structure and a buried channel structure are described. Reasons for the particular imager designs are discussed.
A Project Manager’s Personal Attributes as Predictors for Success
2007-03-01
Northouse (2004) explains that leadership is highly a researched topic with much written. Yet, a definitive description of this phenomenon is difficult to...express because of its complexity. Even though leadership has varied descriptions and conceptualizations, Northouse states that the concept of...characteristic of leadership is not an accurate predictor of performance. Leadership is a complex, multi-faceted attribute ( Northouse , 2004) and specific
A hydrogen fuel cell for rapid, enzyme-catalysed organic synthesis with continuous monitoring.
Wan, Lei; Megarity, Clare F; Siritanaratkul, Bhavin; Armstrong, Fraser A
2018-01-23
A one-pot fuel cell for specific, enzyme-catalysed organic synthesis, with continuous monitoring of rate and reaction progress, combines an electrode catalysing rapid, reversible and diffusion-controlled interconversion of NADP + and NADPH with a Pt electrode catalysing 2H + /H 2 interconversion. This Communication demonstrates its performance and characteristics using the reductive amination of 2-oxoglutarate as a test system.
Zhao, Huifang; Heard, Stephen O; Mullen, Marie T; Crawford, Sybil; Goldberg, Robert J; Frendl, Gyorgy; Lilly, Craig M
2012-06-01
Limited research has been conducted to compare the test characteristics of the 1991 and 2001 sepsis consensus definitions. This study assessed the accuracy of the two sepsis consensus definitions among adult critically ill patients compared to sepsis case adjudication by three senior clinicians. Observational study of patients admitted to intensive care units. Seven intensive care units of an academic medical center. A random sample of 960 patients from all adult intensive care unit patients between October 2007 and December 2008. None. Sensitivity, specificity, and the area under the receiver operating characteristic curve for the two consensus definitions were calculated by comparing the number of patients who met or did not meet consensus definitions vs. the number of patients who were or were not diagnosed with sepsis by adjudication. The 1991 sepsis definition had a high sensitivity of 94.6%, but a low specificity of 61.0%. The 2001 sepsis definition had a slightly increased sensitivity but a decreased specificity, which were 96.9% and 58.3%, respectively. The areas under the receiver operating characteristic curve for the two definitions were not statistically different (0.778 and 0.776, respectively). The sensitivities and areas under the receiver operating characteristic curve of both definitions were lower at the 24-hr time window level than those of the intensive care unit stay level, though their specificities increased slightly. Fever, high white blood cell count or immature forms, low Glasgow coma score, edema, positive fluid balance, high cardiac index, low PaO2/FIO2 ratio, and high levels of creatinine and lactate were significantly associated with sepsis by both definitions and adjudication. Both the 1991 and the 2001 sepsis definition have a high sensitivity but low specificity; the 2001 definition has a slightly increased sensitivity but a decreased specificity compared to the 1991 definition. The diagnostic performances of both definitions were suboptimal. A parsimonious set of significant predictors for sepsis diagnosis is likely to improve current sepsis case definitions.
Agawin, N S.R.; Duarte, C M.; Fortes, M D.; Uri, J S.; Vermaat, J E.
2001-06-01
The analysis of the temporal changes in shoot density, areal leaf biomass, leaf growth and parameters of the photosynthesis-irradiance relationship of three tropical seagrass species (Enhalus acoroides, Thalassia hemprichii and Cymodocea rotundata), co-existing in a shallow subtidal meadow in Cape Bolinao, Philippines, shows that species-specific traits are significant sources of temporal variability, and indicates that these seagrass species respond differently to a common environmental forcing. Species-specific differences are much less important as source of variability of the temporal change in chlorophyll concentration of seagrass leaves. The results indicate that the temporal changes in photosynthetic performance of these seagrasses were driven by environmental forcing and their specific responses to it mostly, but the temporal change in their abundance and leaf growth was also controlled by other factors. The significant contribution of species-specific factors in the temporal changes of biomass, growth and photosynthetic performance of co-occurring seagrass species in Cape Bolinao should contribute to the maintenance of the multispecific, highly productive meadows characteristic of pristine coastal ecosystems in Southeast (SE) Asia.
NASA Technical Reports Server (NTRS)
Whitney, W. J.
1977-01-01
The stage work distribution among the three stages was very close to the design value. The specific work output-mass flow characteristics of the three stages were closely matched. The efficiency of the 3 1/2 stage turbine at design specific work output and design speed was within 0.008 of the estimated value, and this agreement was felt to demonstrate the adequacy of the prediction method in the high stage loading factor regime.
Stage 4S neuroblastoma tumors show a characteristic DNA methylation portrait
Decock, Anneleen; Ongenaert, Maté; De Wilde, Bram; Brichard, Bénédicte; Noguera, Rosa; Speleman, Frank; Vandesompele, Jo
2016-01-01
ABSTRACT Stage 4S neuroblastoma (NB) is a special type of NB found in infants with metastases at diagnosis and is associated with an excellent outcome due to its remarkable capacity to undergo spontaneous regression. As genomics have not been able to explain this intriguing clinical presentation, we here aimed at profiling the DNA methylome of stage 4S NB to better understand this phenomenon. To this purpose, differential methylation analyses between International Neuroblastoma Staging System (INSS) stage 4S, stage 4 and stage 1/2 were performed, using methyl-CpG-binding domain (MBD) sequencing data of 14 stage 4S, 14 stage 4, and 13 stage 1/2 primary NB tumors (all MYCN non-amplified in order not to confound results). Stage 4S-specific hyper- and hypomethylated promoters were determined and further characterized for genomic localization and function by cytogenetic band enrichment, gene set enrichment, transcription factor target enrichment and differential RNA expression analyses. We show that specific chromosomal locations are enriched for stage 4S differentially methylated promoters and that stage 4S tumors show characteristic hypermethylation of specific subtelomeric promoters. Furthermore, genes involved in important oncogenic pathways, in neural crest development and differentiation, and in epigenetic processes are differentially methylated and expressed in stage 4S tumors. Based on these findings, we describe new biological mechanisms possibly contributing to the stage 4S-specific tumor biology and spontaneous regression. In conclusion, this study is the first to describe the highly characteristic stage 4S DNA methylome. These findings will open new avenues to further unravel the NB pathology in general and stage 4S disease specifically. PMID:27599161
Enhancing case definitions for surveillance of human monkeypox in the Democratic Republic of Congo.
Osadebe, Lynda; Hughes, Christine M; Shongo Lushima, Robert; Kabamba, Joelle; Nguete, Beatrice; Malekani, Jean; Pukuta, Elisabeth; Karhemere, Stomy; Muyembe Tamfum, Jean-Jacques; Wemakoy Okitolonda, Emile; Reynolds, Mary G; McCollum, Andrea M
2017-09-01
Human monkeypox (MPX) occurs at appreciable rates in the Democratic Republic of Congo (DRC). Infection with varicella zoster virus (VZV) has a similar presentation to that of MPX, and in areas where MPX is endemic these two illnesses are commonly mistaken. This study evaluated the diagnostic utility of two surveillance case definitions for MPX and specific clinical characteristics associated with laboratory-confirmed MPX cases. Data from a cohort of suspect MPX cases (identified by surveillance over the course of a 42 month period during 2009-2014) from DRC were used; real-time PCR diagnostic test results were used to establish MPX and VZV diagnoses. A total of 333 laboratory-confirmed MPX cases, 383 laboratory-confirmed VZV cases, and 36 cases that were determined to not be either MPX or VZV were included in the analyses. Significant (p<0.05) differences between laboratory-confirmed MPX and VZV cases were noted for several signs/symptoms including key rash characteristics. Both surveillance case definitions had high sensitivity and low specificities for individuals that had suspected MPX virus infections. Using 12 signs/symptoms with high sensitivity and/or specificity values, a receiver operator characteristic analysis showed that models for MPX cases that had the presence of 'fever before rash' plus at least 7 or 8 of the 12 signs/symptoms demonstrated a more balanced performance between sensitivity and specificity. Laboratory-confirmed MPX and VZV cases presented with many of the same signs and symptoms, and the analysis here emphasized the utility of including 12 specific signs/symptoms when investigating MPX cases. In order to document and detect endemic human MPX cases, a surveillance case definition with more specificity is needed for accurate case detection. In the absence of a more specific case definition, continued emphasis on confirmatory laboratory-based diagnostics is warranted.
Tin Tin, Sandar; Elwood, J Mark; Lawrenson, Ross; Campbell, Ian
2017-03-03
To assess the completeness of data on body mass index (BMI) in a regional breast cancer register, and its association with patient characteristics and clinical outcomes. This analysis used the data from the Waikato Breast Cancer Register and involved all women who were diagnosed with primary breast cancer in the Waikato District Health Board Region between January 2000 and June 2014. Patients with recorded BMI were compared with those with missing data in terms of demographics, disease factors and treatment factors. Cox regression modelling was performed, and hazards of specific outcomes associated with missing data on BMI were assessed. Of the 3,536 patients included in this analysis, 27.4% had missing data on BMI. Missing data was more frequent in older patients, rural dwellers, patients with comorbidities, screen detected patients, patients with early stage or low grade cancer and hormone receptor positive patients, but was minimal in patients who received chemotherapy. Patients with missing data were less likely to experience loco-regional recurrence (although not significant), metastasis and breast cancer specific mortality, but more likely to experience death from other causes even after demographic, disease and treatment factors were adjusted. Height or weight or both were not recorded for more than one quarter of the patients. Missing data was differential by specific patient characteristics and clinical outcomes.
Tighiouart, Hocine; Meyer, Klemens B.; Miskulin, Dana C.
2011-01-01
The Centers for Medicare and Medicaid Services (CMS) designated the achieved urea reduction ratio (URR) as a pay-for-performance measure, but to what extent this measure reflects patient characteristics and adherence instead of its intent to reflect facility performance is unknown. Here, we quantified the contributions of patient case-mix and adherence to the variability in achieving URR targets across dialysis facilities. We found that 92% of 10,069 hemodialysis patients treated at 173 facilities during the last quarter of 2004 achieved the target URR ≥65%. Mixed-effect models with random intercept for dialysis facility revealed a significant facility effect: 11.5% of the variation in achievement of target URR was attributable to the facility level. Adjusting for patient case-mix reduced the proportion of variation attributable to the facility level to 6.7%. Patient gender, body surface area, dialysis access, and adherence with treatment strongly associated with achievement of the URR target. We could not identify specific facility characteristics that explained the remaining variation between facilities. These data suggest that if adherence is not a modifiable patient characteristic, providers could be unfairly penalized for caring for these patients under current CMS policy. These penalties may have unintended consequences. PMID:22025629
Abramson, Zvi Howard; Levi, Orit
2008-11-01
Studies have demonstrated associations between physicians' characteristics, specifically personal health behavior, and their reported prevention counseling behavior. This study, performed in 2007, examines associations between patients getting immunized against influenza and characteristics of their primary care physicians, including whether they themselves were immunized. Computerized data were extracted on 29,447 patients aged 65 years and over registered in the largest health maintenance organization (HMO) in the Jerusalem area and on their primary care physicians. Further physician data were collected from a questionnaire distributed to a large sample of physicians. Logistic regression was performed with patient immunization as the dependent variable. Patients were more likely to get vaccinated if their physician was vaccinated and if the physician was female or a specialist or had studied in West Europe or America. Patients of physicians who reported exercising regularly and of physicians who knew that the vaccine can't cause influenza were also more likely to get immunized. These associations of physician factors with patient immunization, though statistically significant, were weaker than those previously reported with physician influenza vaccination counseling. Physician's beliefs and medical education and personal health behavior are of importance in determining patient vaccination. An increase in population immunization rates may possibly be achieved by programs directed at enhancing physician knowledge and self immunization.
NASA Astrophysics Data System (ADS)
Galevskii, G. V.; Rudneva, V. V.; Galevskii, S. G.; Tomas, K. I.; Zubkov, M. S.
2016-04-01
The experience of production and study on properties of nano-disperse chromium and titanium borides and carbides, and silicon carbide has been generalized. The structure and special service aspects of utilized plasma-metallurgical complex equipped with a three-jet direct-flow reactor with a capacity of 150 kW have been outlined. Processing, heat engineering and service life characteristics of the reactor are specified. The synthesis parameters of borides and carbides, as well as their basic characteristics in nano-disperse condition and their production flow diagram are outlined. Engineering and economic performance of synthesizing borides in laboratory and industrial conditions is assessed, and the respective segment of the international market as well. The work is performed at State Siberian Industrial University as a project part of the State Order of Ministry of Science and Education of the Russian Federation No. 11.1531/2014/K.
Performance of current-in-plane pseudo-spin-valve devices on CMOS silicon-on-insulator underlayers
NASA Astrophysics Data System (ADS)
Katti, R. R.; Zou, D.; Reed, D.; Schipper, D.; Hynes, O.; Shaw, G.; Kaakani, H.
2003-05-01
Prior work has shown that current-in-plane (CIP) giant magnetoresistive (GMR) pseudo-spin-valve (PSV) devices grown on bulk Si wafers and bulk complementary metal-oxide semiconductor (CMOS) underlayers exhibit write and read characteristics that are suitable for application as nonvolatile memory devices. In this work, CIP GMR PSV devices fabricated on silicon-on-insulator CMOS underlayers are shown to support write and read performance. Reading and writing fields for selected devices are shown to be approximately 25%-50% that of unselected devices, which provides a margin for reading and writing specific bits in a memory without overwriting bits and without disturbing other bits. The switching characteristics of experimental devices were compared to and found to be similar with Landau-Lifschitz-Gilbert micromagnetic modeling results, which allowed inferring regions of reversible and irreversible rotations in magnetic reversal processes.
A rapid method for optimization of the rocket propulsion system for single-stage-to-orbit vehicles
NASA Technical Reports Server (NTRS)
Eldred, C. H.; Gordon, S. V.
1976-01-01
A rapid analytical method for the optimization of rocket propulsion systems is presented for a vertical take-off, horizontal landing, single-stage-to-orbit launch vehicle. This method utilizes trade-offs between propulsion characteristics affecting flight performance and engine system mass. The performance results from a point-mass trajectory optimization program are combined with a linearized sizing program to establish vehicle sizing trends caused by propulsion system variations. The linearized sizing technique was developed for the class of vehicle systems studied herein. The specific examples treated are the optimization of nozzle expansion ratio and lift-off thrust-to-weight ratio to achieve either minimum gross mass or minimum dry mass. Assumed propulsion system characteristics are high chamber pressure, liquid oxygen and liquid hydrogen propellants, conventional bell nozzles, and the same fixed nozzle expansion ratio for all engines on a vehicle.
NASA Astrophysics Data System (ADS)
Artisyuk, V.; Ignatyuk, A.; Korovin, Yu.; Lopatkin, A.; Matveenko, I.; Stankovskiy, A.; Titarenko, Yu.
2005-05-01
Transmutation of nuclear wastes (Minor Actinides and Long-Lived Fission Products) remains an important option to reduce the burden of high-level waste on final waste disposal in deep geological structures. Accelerator-Driven Systems (ADS) are considered as possible candidates to perform transmutation due to their subcritical operation mode that eliminates some of the serious safety penalties unavoidable in critical reactors. Specific requirements to nuclear data necessary for ADS transmutation analysis is the main subject of the ISTC Project ♯2578 which started in 2004 to identify the areas of research priorities in the future. The present paper gives a summary of ongoing project stressing the importance of nuclear data for blanket performance (reactivity behavior with associated safety characteristics) and uncertainties that affect characteristics of neutron producing target.
NASA Technical Reports Server (NTRS)
Curran, Francis M.; Sovie, Amy J.; Haag, Thomas W.
1989-01-01
The effect of nozzle configuration on the operating characteristics of a low power dc arcjet thruster was determined. A conical nozzle with a 30 deg converging angle, a 20 deg diverging angle, and an area ratio of 225 served as the baseline case. Variations on the geometry included bell-shaped contours both up and downstream, and a downstream trumpet-shaped contour. The nozzles were operated over a range of specific power near that anticipated for on-orbit operation. Mass flow rate, thrust, current, and voltage were monitored to provide accurate comparisons between nozzles. The upstream contour was found to have minimal effect on arcjet operation. It was determined that the contour of the divergent section of the nozzle, that serves as the anode, was very important in determining the location of arc attachment, and thus had a significant impact on arcjet performance. The conical nozzle was judged to have the optimal current/voltage characteristics and produced the best performance of the nozzles tested.
NASA Technical Reports Server (NTRS)
Curran, Francis M.; Sovie, Amy J.; Haag, Thomas W.
1989-01-01
The effect of nozzle configuration on the operating characteristics of a low power dc arcjet thruster was determined. A conical nozzle with a 30 deg converging angle, a 20 deg diverging angle, and an area ratio of 225 served as the baseline case. Variations on the geometry included bell-shaped contours both up and downstream, and a downstream trumpet-shaped contour. The nozzles were operated over a range of specific power near that anticipated for on-orbit operation. Mass flow rate, thrust, current, and voltage were monitored to provide accurate comparisons between nozzles. The upstream contour was found to have minimal effect on arcjet operation. It was determined that the contour of the divergent section of the nozzle, that serves as the anode, was very important in determining the location of arc attachment, and thus had a significant impact on arcjet performance. The conical nozzle was judged to have the optimal current/voltage characteristics and produced the best performance of the nozzles tested.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nunes, A.; Zanetti, F.M.; Lyra, M.L., E-mail: marcelo@fis.ufal.br
2016-10-15
In this work, we study the transmission characteristics of a two-channels coupler model system using the Boundary Wall Method (BWM) to determine the solution of the corresponding scattering problem of an incident plane wave. We show that the BWM provides detailed information regarding the transmission resonances. In particular, we focus on the case of single channel input aiming to explore the energy switching performance of the coupler. We show that the coupler geometry can be tailored to allow for the first transmission resonances to be predominantly transmitted on specific output channels, an important characteristic for the realization of logical operations.more » - Highlights: • The switching performance of a coupled waveguide device is studied via the boundary wall method. • The method efficiently identifies all resonant transmission modes. • Energy switching is controlled and optimized as a function of the device geometry.« less
2010-01-01
Background The Oncotype DX® Colon Cancer Assay is a new diagnostic test for determining the likelihood of recurrence in stage II colon cancer patients after surgical resection using fixed paraffin embedded (FPE) primary colon tumor tissue. Like the Oncotype DX Breast Cancer Assay, this is a high complexity, multi-analyte, reverse transcription (RT) polymerase chain reaction (PCR) assay that measures the expression levels of specific cancer-related genes. By capturing the biology underlying each patient's tumor, the Oncotype DX Colon Cancer Assay provides a Recurrence Score (RS) that reflects an individualized risk of disease recurrence. Here we describe its analytical performance using pre-determined performance criteria, which is a critical component of molecular diagnostic test validation. Results All analytical measurements met pre-specified performance criteria. PCR amplification efficiency for all 12 assays was high, ranging from 96% to 107%, while linearity was demonstrated over an 11 log2 concentration range for all assays. Based on estimated components of variance for FPE RNA pools, analytical reproducibility and precision demonstrated low SDs for individual genes (0.16 to 0.32 CTs), gene groups (≤0.05 normalized/aggregate CTs) and RS (≤1.38 RS units). Conclusions Analytical performance characteristics shown here for both individual genes and gene groups in the Oncotype DX Colon Cancer Assay demonstrate consistent translation of specific biology of individual tumors into clinically useful diagnostic information. The results of these studies illustrate how the analytical capability of the Oncotype DX Colon Cancer Assay has enabled clinical validation of a test to determine individualized recurrence risk after colon cancer surgery. PMID:21176237
Kraal, Jos J; Vromen, Tom; Spee, Ruud; Kemps, Hareld M C; Peek, Niels
2017-10-15
Although exercise-based cardiac rehabilitation improves exercise capacity of coronary artery disease patients, it is unclear which training characteristic determines this improvement. Total energy expenditure and its constituent training characteristics (training intensity, session frequency, session duration and programme length) vary considerably among clinical trials, making it hard to compare studies directly. Therefore, we performed a systematic review and meta-regression analysis to assess the effect of total energy expenditure and its constituent training characteristics on exercise capacity. We identified randomised controlled trials comparing continuous aerobic exercise training with usual care for patients with coronary artery disease. Studies were included when training intensity, session frequency, session duration and programme length was described, and exercise capacity was reported in peakVO 2 . Energy expenditure was calculated from the four training characteristics. The effect of training characteristics on exercise capacity was determined using mixed effects linear regression analyses. The analyses were performed with and without total energy expenditure as covariate. Twenty studies were included in the analyses. The mean difference in peakVO 2 between the intervention group and control group was 3.97ml·min -1 ·kg -1 (p<0.01, 95% CI 2.86 to 5.07). Total energy expenditure was significantly related to improvement of exercise capacity (effect size 0.91ml·min -1 ·kg -1 per 100J·kg, p<0.01, 95% CI 0.77 to 1.06), no effect was found for its constituent training characteristics after adjustment for total energy expenditure. We conclude that the design of an exercise programme should primarily be aimed at optimising total energy expenditure rather than on one specific training characteristic. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Towards a characterization of information automation systems on the flight deck
NASA Astrophysics Data System (ADS)
Dudley, Rachel Feddersen
This thesis summarizes research to investigate the characteristics that define information automation systems used on aircraft flight decks and the significant impacts that these characteristics have on pilot performance. Major accomplishments of the work include the development of a set of characteristics that describe information automation systems on the flight deck and an experiment designed to study a subset of these characteristics. Information automation systems on the flight deck are responsible for the collection, processing, analysis, and presentation of data to the flightcrew. These systems pose human factors issues and challenges that must be considered by designers of these systems. Based on a previously developed formal definition of information automation for aircraft flight deck systems, an analysis process was developed and conducted to reach a refined set of information automation characteristics. In this work, characteristics are defined as a set of properties or attributes that describe an information automation system's operation or behavior, which can be used to identify and assess potential human factors issues. Hypotheses were formed for a subset of the characteristics: Automation Visibility, Information Quality, and Display Complexity. An experimental investigation was developed to measure performance impacts related to these characteristics, which showed mixed results of expected and surprising findings, with many interactions. A set of recommendations were then developed based on the experimental observations. Ensuring that the right information is presented to pilots at the right time and in the appropriate manner is the job of flight deck system designers. This work provides a foundation for developing recommendations and guidelines specific to information automation on the flight deck with the goal of improving the design and evaluation of information automation systems before they are implemented.
Jenke, Dennis; Sadain, Salma; Nunez, Karen; Byrne, Frances
2007-01-01
The performance of an ion chromatographic method for measuring citrate and phosphate in pharmaceutical solutions is evaluated. Performance characteristics examined include accuracy, precision, specificity, response linearity, robustness, and the ability to meet system suitability criteria. In general, the method is found to be robust within reasonable deviations from its specified operating conditions. Analytical accuracy is typically 100 +/- 3%, and short-term precision is not more than 1.5% relative standard deviation. The instrument response is linear over a range of 50% to 150% of the standard preparation target concentrations (12 mg/L for phosphate and 20 mg/L for citrate), and the results obtained using a single-point standard versus a calibration curve are essentially equivalent. A small analytical bias is observed and ascribed to the relative purity of the differing salts, used as raw materials in tested finished products and as reference standards in the analytical method. The assay is specific in that no phosphate or citrate peaks are observed in a variety of method-related solutions and matrix blanks (with and without autoclaving). The assay with manual preparation of the eluents is sensitive to the composition of the eluent in the sense that the eluent must be effectively degassed and protected from CO(2) ingress during use. In order for the assay to perform effectively, extensive system equilibration and conditioning is required. However, a properly conditioned and equilibrated system can be used to test a number of samples via chromatographic runs that include many (> 50) injections.
Mendonça, Ivete Lopes de; Batista, Joilson Ferreira; Werneck, Guilherme Loureiro; Soares, Maria Regiane Araújo; Costa, Dorcas Lamounier; Costa, Carlos Henrique Nery
2017-01-01
The control of reservoirs for Leishmania infantum -induced zoonotic visceral leishmaniasis requires the identification of dogs posing a population risk. Here, we assessed the performance of several assays to identify Lutzomyia longipalpis infectious dogs. We evaluated 99 dogs that were positive for visceral leishmaniasis based on parasite identification. Serological analyses were performed using an enzyme-linked immunosorbent assay, immunofluorescence antibody tests in 1:40 and 1:80 dilutions, rapid dual path platform tests, immunochromatographic assay with a recombinant rK39 antigen, fast agglutination screening tests, and direct agglutination tests. We also performed PCR to analyze peripheral blood and xenodiagnosis. Forty-six dogs infected at least one L. longipalpis specimen. Although the serological test sensitivities were above 85% for detecting L. longipalpis infectious dogs, none showed a satisfactory performance, as both specificity (0.06 to 13%) and the area under the receiver operating characteristic curve (45 to 53%) were low. The PCR results were also weak, with a sensitivity of 30%, specificity of 72%, and an area under the receiver operating characteristic curve of 51%. The infected L. longipalpis proportion was higher among asymptomatic dogs than symptomatic dogs. Among the symptomatic dogs, those with ulceration-free skin diseases were more infectious, with an odds ratio of 9.3 (confidence interval of 1.10 - 428.5). The larger the number of insects fed, the greater the detected infectiousness. Our study supports the imperative to develop novel technologies for identifying the infectious dogs that transmit L. infantum for the benefit of public health.
NASA Astrophysics Data System (ADS)
Nitnaware, Pravin Tukaram; Suryawanshi, Jiwak G.
2018-01-01
This paper shows exhaust gas recirculation (EGR) effects on multi-cylinder bi-fuel SI engine using blends of 0, 5, 10 and 15% hydrogen by energy with CNG. All trials are performed at a speed of 3000, 3500 and 4000 rpm with EGR rate of 0, 5, 10 and 15%, with equal spark timing and injection pressure of 2.6 bar. At specific hydrogen percentage with increase in EGR rate NOx emission reduces drastically and increases with increase in hydrogen addition. Hydrocarbon (HC) and carbon monoxide (CO) emission decreases with increase in speed and hydrogen addition. There is considerable improvement in brake thermal efficiency (BTE) and brake specific energy consumption (BSEC) at 15% EGR rate. At 3000 rpm, 5% EGR rate with 5% hydrogen had shown maximum cylinder pressure. Brake specific fuel consumption (b.s.f.c) increased with increase in EGR rate and decreased with increase in hydrogen addition for all speeds.
DEVELOPMENT OF CRASSPHAGE-BASED QPCR ASSAYS ...
A newly discovered bacteriophage, “crAssphage”, is predicted to be both highlyabundant and predominantly human-associated, both ideal characteristics for a human-specific fecal indicator. A total of 384 end-point PCR primers were designed along the length of the crAssphage genome, eliminating regions suspected to be hypervariable or react with other animal sources. The primer pairs were rigorously tested in three rounds of screening for specificity, geographic variability, limit of detection, and environmental water performance. The two best performing assays, crAss056 and crAss064, were adapted to a qPCR platform and exhibited a specificity of 98.0% and 98.9%, respectively. The markers’ abundance was compared with two bacterial based assays and were found at concentrations at or above the bacterial based assays in wastewater influent and impacted environmental waters. This poster will present the methodology of the novel marker development and the potential uses for this technology in maintaining sustainable waterways in the future. To inform the public.
Henderson, Louise M.; Benefield, Thad; Marsh, Mary W.; Schroeder, Bruce F.; Durham, Danielle; Yankaskas, Bonnie C.; Bowling, J. Michael
2014-01-01
Purpose To determine whether the mammographic technologist has an effect on the radiologists’ interpretative performance of screening mammography in community practice. Materials and Methods In this institutional review board approved retrospective cohort study, we included Carolina Mammography Registry (CMR) data from 372 radiologists and 356 mammographic technologists from 1994 to 2009 who performed 1,003,276 screening mammograms. Measures of interpretative performance (recall rate, sensitivity, specificity, positive predictive value (PPV1), and cancer detection rate (CDR)) were ascertained prospectively with cancer outcomes collected from the state cancer registry and pathology reports. To determine if the mammographic technologist influenced the radiologists’ performance, we employed mixed effects logistic regression models, including a radiologist-specific random effect and taking into account the clustering of examinations across women, separately for screen-film mammography (SFM) and full field digital mammography (FFDM). Results Of the 356 mammographic technologists included, 343 performed 889,347 SFM examinations and 51 performed 113,929 FFDM examinations, and 38 performed both SFM and FFDM. A total of 4,328 cancers were reported for SFM and 564 cancers for FFDM. The technologists had a statistically significant effect on the radiologists’ recall rate, sensitivity, specificity and CDR for both SFM and FFDM (p-values<0.01). For PPV1, variability by technologist was observed for SFM (p-value<0.0001) but not for FFDM (p-value=0.088). Conclusion The interpretative performance of radiologists in screening mammography varies substantially by the technologist performing the examination. Additional studies should aim to identify technologist characteristics that may explain this variation. PMID:25435185
Henry, Elizabeth; Berglund, Kathy; Millar, Lynn; Locke, Frederick
2015-12-01
Recent evidence suggests performing a warm-up prior to golf can improve performance and reduce injuries. While some characteristics of effective golf warm-ups have been determined, no studies have explored the immediate effects of a rotational-specific warm-up with elements of motor control on the biomechanical aspects of the full X-Factor and X-Factor Stretch during the golf swing. Thirty-six amateur golfers (mean ± SD age: 64 ± 8 years old; 75% male) were randomized into a Dynamic Rotation-Specific Warm-up group (n=20), or a Sham Warm-up group (n=16). X-Factor and X-Factor Stretch were measured at baseline and immediately following the warm-up. Mixed model ANCOVAs were used to determine if a Group*Time interaction existed for each variable with group as the between-subjects variable and time as the within-subjects variable. The mixed model ANCOVAs did not reveal a statistically significant group*time interaction for X-Factor or X-Factor Stretch. There was not a significant main effect for time for X-Factor but there was for X-Factor Stretch. These results indicate that neither group had a significant effect on improving X-Factor, however performing either warm-up increased X-Factor Stretch without significant difference between the two. The results of this study suggest that performing the Dynamic Rotation-Specific Warm-up did not increase X-Factor or X-Factor Stretch when controlled for age compared to the Sham Warm-up. Further study is needed to determine the long-term effects of the Dynamic Rotation-Specific Warm-up on performance factors of the golf swing while examining across all ages. 2b.
The design and operating characteristics of an advanced 30-kW ammonia arcjet engine
NASA Technical Reports Server (NTRS)
Deininger, William D.; Pivirotto, Thomas J.; Brophy, John R.
1987-01-01
Experimental investigations were conducted to evaluate the effects of a contoured nozzle and modified cathode shape on ammonia arcjet engine performance. The contoured nozzle performance data were compared to the performance data of an arcjet which had a 38-deg included-angle, conical nozzle. Thrust improvements of up to 10 percent were demonstrated which corresponded to 3 percent improvements in specific impulse and 10 percent improvements in thrust efficiency. Performance characterizations for the modified cathode tip were conducted with the contoured nozzle arcjet. A uniform 15 percent decrease in arc voltage was demonstrated over a mass flow range of 0.175 to 0.350 g/s. A 4 percent improvement in thrust efficiency was noted at 22.0 kW.
Radiologists’ Interpretive Skills in Screening vs. Diagnostic Mammography: Are They Related?
Elmore, Joann G.; Cook, Andrea J.; Bogart, Andy; Carney, Patricia A.; Geller, Berta; Taplin, Stephen; Buist, Diana SM; Onega, Tracy; Lee, Christoph I.; Miglioretti, Diana L.
2016-01-01
Purpose To determine whether radiologists who perform well in screening also perform well in interpreting diagnostic mammography. Materials & Methods We evaluated the accuracy of 468 radiologists interpreting 2,234,947 screening and 196,164 diagnostic mammograms. Adjusting for site, radiologist, and patient characteristics, we identified radiologists with performance in the highest tertile and compared to those with lower performance. Results A moderate correlation was noted for radiologists’ accuracy when interpreting screening versus their accuracy on diagnostic exams: sensitivity (rspearman=0.51, 95% CI: 0.22, 0.80; P=0.0006), specificity (rspearman=0.40, 95% CI: 0.30, 0.49; P<0.0001). Conclusion Different educational approaches to screening and diagnostic imaging should be considered. PMID:27438069
Ball, David A; Mehta, Gunjan D; Salomon-Kent, Ronit; Mazza, Davide; Morisaki, Tatsuya; Mueller, Florian; McNally, James G; Karpova, Tatiana S
2016-12-01
In vivo single molecule tracking has recently developed into a powerful technique for measuring and understanding the transient interactions of transcription factors (TF) with their chromatin response elements. However, this method still lacks a solid foundation for distinguishing between specific and non-specific interactions. To address this issue, we took advantage of the power of molecular genetics of yeast. Yeast TF Ace1p has only five specific sites in the genome and thus serves as a benchmark to distinguish specific from non-specific binding. Here, we show that the estimated residence time of the short-residence molecules is essentially the same for Hht1p, Ace1p and Hsf1p, equaling 0.12-0.32 s. These three DNA-binding proteins are very different in their structure, function and intracellular concentration. This suggests that (i) short-residence molecules are bound to DNA non-specifically, and (ii) that non-specific binding shares common characteristics between vastly different DNA-bound proteins and thus may have a common underlying mechanism. We develop new and robust procedure for evaluation of adverse effects of labeling, and new quantitative analysis procedures that significantly improve residence time measurements by accounting for fluorophore blinking. Our results provide a framework for the reliable performance and analysis of single molecule TF experiments in yeast. Published by Oxford University Press on behalf of Nucleic Acids Research 2016. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Long, Wu-Jian; Khayat, Kamal Henri; Lemieux, Guillaume; Hwang, Soo-Duck; Han, Ning-Xu
2014-03-27
Adequate selection of material constituents and test methods are necessary for workability specifications and performance of hardened concrete. An experimental program was performed to evaluate the suitability of various test methods for workability assessment and to propose performance specifications of prestressed concrete. In total, 33 self-consolidating concrete (SCC) mixtures made with various mixture proportioning parameters, including maximum size and type of aggregate, type and content of binder, and w/cm were evaluated. Correlations among various test results used in evaluating the workability responses are established. It is recommended that SCC should have slump flow values of 635-760 mm. To ensure proper filling capacity greater than 80%, such concrete should have a passing ability that corresponds to L-box blocking ratio (h₂/h₁) ≥ 0.5, J-Ring flow of 570-685 mm, slump flow minus J-Ring flow diameter ≤75 mm. Moreover, Stable SCC should develop a column segregation index lower than 5%, and rate of settlement at 30 min of 0.27%/h for SCC proportioned with 12.5 or 9.5 mm MSA. It is recommended that SCC should have a plastic viscosity of 100-225 Pa·s and 100-400 Pa·s for concrete made with crushed aggregate and gravel, respectively, to ensure proper workability.
Simulating the Use of Alternative Fuels in a Turbofan Engine
NASA Technical Reports Server (NTRS)
Litt, Jonathan S.; Chin, Jeffrey Chevoor; Liu, Yuan
2013-01-01
The interest in alternative fuels for aviation has created a need to evaluate their effect on engine performance. The use of dynamic turbofan engine simulations enables the comparative modeling of the performance of these fuels on a realistic test bed in terms of dynamic response and control compared to traditional fuels. The analysis of overall engine performance and response characteristics can lead to a determination of the practicality of using specific alternative fuels in commercial aircraft. This paper describes a procedure to model the use of alternative fuels in a large commercial turbofan engine, and quantifies their effects on engine and vehicle performance. In addition, the modeling effort notionally demonstrates that engine performance may be maintained by modifying engine control system software parameters to account for the alternative fuel.
WOMBAT: A Scalable and High-performance Astrophysical Magnetohydrodynamics Code
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendygral, P. J.; Radcliffe, N.; Kandalla, K.
2017-02-01
We present a new code for astrophysical magnetohydrodynamics specifically designed and optimized for high performance and scaling on modern and future supercomputers. We describe a novel hybrid OpenMP/MPI programming model that emerged from a collaboration between Cray, Inc. and the University of Minnesota. This design utilizes MPI-RMA optimized for thread scaling, which allows the code to run extremely efficiently at very high thread counts ideal for the latest generation of multi-core and many-core architectures. Such performance characteristics are needed in the era of “exascale” computing. We describe and demonstrate our high-performance design in detail with the intent that it maymore » be used as a model for other, future astrophysical codes intended for applications demanding exceptional performance.« less
Herbst, Meghan K.; Rosenberg, Graeme; Daniels, Brock; Gross, Cary P.; Singh, Dinesh; Molinaro, Annette M.; Luty, Seth; Moore, Christopher L.
2016-01-01
Study objective Hydronephrosis is readily visible on ultrasonography and is a strong predictor of ureteral stones, but ultrasonography is a user-dependent technology and the test characteristics of clinician-performed ultrasonography for hydronephrosis are incompletely characterized, as is the effect of ultrasound fellowship training on predictive accuracy. We seek to determine the test characteristics of ultrasonography for detecting hydronephrosis when performed by clinicians with a wide range of experience under conditions of direct patient care. Methods This was a prospective study of patients presenting to an academic medical center emergency department with suspected renal colic. Before computed tomography (CT) results, an emergency clinician performed bedside ultrasonography, recording the presence and degree of hydronephrosis. CT data were abstracted from the dictated radiology report by an investigator blinded to the bedside ultrasonographic results. Test characteristics of bedside ultrasonography for hydronephrosis were calculated with the CT scan as the reference standard, with test characteristics compared by clinician experience stratified into 4 levels: attending physicians with emergency ultrasound fellowship training, attending physicians without emergency ultrasound fellowship training, ultrasound experienced non–attending physician clinicians (at least 2 weeks of ultrasound training), and ultrasound inexperienced non–attending physician clinicians (physician assistants, nurse practitioners, off-service rotators, and first-year emergency medicine residents with fewer than 2 weeks of ultrasound training). Results There were 670 interpretable bedside ultrasonographic tests performed by 144 unique clinicians, 80.9% of which were performed by clinicians directly involved in the care of the patient. On CT, 47.5% of all subjects had hydronephrosis and 47.0% had a ureteral stone. Among all clinicians, ultrasonography had a sensitivity of 72.6% (95% confidence interval [CI] 65.4% to 78.9%), specificity of 73.3% (95% CI 66.1% to 79.4%), positive likelihood ratio of 2.72 (95% CI 2.25 to 3.27), and negative likelihood ratio of 0.37 (95% CI 0.31 to 0.44) for hydronephrosis, using hydronephrosis on CT as the criterion standard. Among attending physicians with fellowship training, ultrasonography had sensitivity of 92.7% (95% CI 83.8% to 96.9%), positive likelihood ratio of 4.97 (95% CI 2.90 to 8.51), and negative likelihood ratio of 0.08 (95% CI 0.03 to 0.23). Conclusion Overall, ultrasonography performed by emergency clinicians was moderately sensitive and specific for detection of hydronephrosis as seen on CT in patients with suspected renal colic. However, presence or absence of hydronephrosis as determined by emergency physicians with fellowship training in ultrasonography yielded more definitive test results. For clinicians without fellowship training, there was no significant difference between groups in the predictive accuracy of the application according to experience level. PMID:24630203
Herbst, Meghan K; Rosenberg, Graeme; Daniels, Brock; Gross, Cary P; Singh, Dinesh; Molinaro, Annette M; Luty, Seth; Moore, Christopher L
2014-09-01
Hydronephrosis is readily visible on ultrasonography and is a strong predictor of ureteral stones, but ultrasonography is a user-dependent technology and the test characteristics of clinician-performed ultrasonography for hydronephrosis are incompletely characterized, as is the effect of ultrasound fellowship training on predictive accuracy. We seek to determine the test characteristics of ultrasonography for detecting hydronephrosis when performed by clinicians with a wide range of experience under conditions of direct patient care. This was a prospective study of patients presenting to an academic medical center emergency department with suspected renal colic. Before computed tomography (CT) results, an emergency clinician performed bedside ultrasonography, recording the presence and degree of hydronephrosis. CT data were abstracted from the dictated radiology report by an investigator blinded to the bedside ultrasonographic results. Test characteristics of bedside ultrasonography for hydronephrosis were calculated with the CT scan as the reference standard, with test characteristics compared by clinician experience stratified into 4 levels: attending physicians with emergency ultrasound fellowship training, attending physicians without emergency ultrasound fellowship training, ultrasound experienced non-attending physician clinicians (at least 2 weeks of ultrasound training), and ultrasound inexperienced non-attending physician clinicians (physician assistants, nurse practitioners, off-service rotators, and first-year emergency medicine residents with fewer than 2 weeks of ultrasound training). There were 670 interpretable bedside ultrasonographic tests performed by 144 unique clinicians, 80.9% of which were performed by clinicians directly involved in the care of the patient. On CT, 47.5% of all subjects had hydronephrosis and 47.0% had a ureteral stone. Among all clinicians, ultrasonography had a sensitivity of 72.6% (95% confidence interval [CI] 65.4% to 78.9%), specificity of 73.3% (95% CI 66.1% to 79.4%), positive likelihood ratio of 2.72 (95% CI 2.25 to 3.27), and negative likelihood ratio of 0.37 (95% CI 0.31 to 0.44) for hydronephrosis, using hydronephrosis on CT as the criterion standard. Among attending physicians with fellowship training, ultrasonography had sensitivity of 92.7% (95% CI 83.8% to 96.9%), positive likelihood ratio of 4.97 (95% CI 2.90 to 8.51), and negative likelihood ratio of 0.08 (95% CI 0.03 to 0.23). Overall, ultrasonography performed by emergency clinicians was moderately sensitive and specific for detection of hydronephrosis as seen on CT in patients with suspected renal colic. However, presence or absence of hydronephrosis as determined by emergency physicians with fellowship training in ultrasonography yielded more definitive test results. For clinicians without fellowship training, there was no significant difference between groups in the predictive accuracy of the application according to experience level. Copyright © 2014 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.
"The caterpillar": a novel reading passage for assessment of motor speech disorders.
Patel, Rupal; Connaghan, Kathryn; Franco, Diana; Edsall, Erika; Forgit, Dory; Olsen, Laura; Ramage, Lianna; Tyler, Emily; Russell, Scott
2013-02-01
A review of the salient characteristics of motor speech disorders and common assessment protocols revealed the need for a novel reading passage tailored specifically to differentiate between and among the dysarthrias (DYSs) and apraxia of speech (AOS). "The Caterpillar" passage was designed to provide a contemporary, easily read, contextual speech sample with specific tasks (e.g., prosodic contrasts, words of increasing length and complexity) targeted to inform the assessment of motor speech disorders. Twenty-two adults, 15 with DYS or AOS and 7 healthy controls (HC), were recorded reading "The Caterpillar" passage to demonstrate its utility in examining motor speech performance. Analysis of performance across a subset of segmental and prosodic variables illustrated that "The Caterpillar" passage showed promise for extracting individual profiles of impairment that could augment current assessment protocols and inform treatment planning in motor speech disorders.
Preparation of near-infrared-labeled targeted contrast agents for clinical translation
NASA Astrophysics Data System (ADS)
Olive, D. Michael
2011-03-01
Targeted fluorophore-labeled contrast agents are moving toward translation to human surgical use. To prepare for future clinical use, we examined the performance of potential ligands targeting the epidermal growth factor receptor, α5β3 integrins, and GLUT transporters for their suitability as directed contrast agents. Each agent was labeled with IRDye 800CW, and near-infrared dye with excitation/emission wavelengths of 789/805 nm, which we determined had favorable toxicity characteristics. The probe molecules examined consisted of Affibodies, nanobodies, peptides, and the sugar 2-deoxy-D-glucose. Each probe was tested for specific and non-specific binding in cell based assays. All probe types showed good performance in mouse models for detecting either spontaneous tumors or tumor xenografts in vivo. Each of the probes tested show promise for future human clinical studies.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 27 2011-07-01 2011-07-01 false Waste specific prohibitions-Soils... Prohibitions on Land Disposal § 268.32 Waste specific prohibitions—Soils exhibiting the toxicity characteristic... from land disposal: any volumes of soil exhibiting the toxicity characteristic solely because of the...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 28 2013-07-01 2013-07-01 false Waste specific prohibitions-Soils... Prohibitions on Land Disposal § 268.32 Waste specific prohibitions—Soils exhibiting the toxicity characteristic... from land disposal: any volumes of soil exhibiting the toxicity characteristic solely because of the...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 28 2012-07-01 2012-07-01 false Waste specific prohibitions-Soils... Prohibitions on Land Disposal § 268.32 Waste specific prohibitions—Soils exhibiting the toxicity characteristic... from land disposal: any volumes of soil exhibiting the toxicity characteristic solely because of the...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Waste specific prohibitions-Soils... Prohibitions on Land Disposal § 268.32 Waste specific prohibitions—Soils exhibiting the toxicity characteristic... from land disposal: any volumes of soil exhibiting the toxicity characteristic solely because of the...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 27 2014-07-01 2014-07-01 false Waste specific prohibitions-Soils... Prohibitions on Land Disposal § 268.32 Waste specific prohibitions—Soils exhibiting the toxicity characteristic... from land disposal: any volumes of soil exhibiting the toxicity characteristic solely because of the...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Surkov, A. V., E-mail: surkov.andrew@gmail.com; Kochkin, V. N.; Pesnya, Yu. E.
2015-12-15
A comparison of measured and calculated neutronic characteristics (fast neutron flux and fission rate of {sup 235}U) in the core and reflector of the IR-8 reactor is presented. The irradiation devices equipped with neutron activation detectors were prepared. The determination of fast neutron flux was performed using the {sup 54}Fe (n, p) and {sup 58}Ni (n, p) reactions. The {sup 235}U fission rate was measured using uranium dioxide with 10% enrichment in {sup 235}U. The determination of specific activities of detectors was carried out by measuring the intensity of characteristic gamma peaks using the ORTEC gamma spectrometer. Neutron fields inmore » the core and reflector of the IR-8 reactor were calculated using the MCU-PTR code.« less
High-harmonic spectroscopy of aligned molecules
NASA Astrophysics Data System (ADS)
Yun, Hyeok; Yun, Sang Jae; Lee, Gae Hwang; Nam, Chang Hee
2017-01-01
High harmonics emitted from aligned molecules driven by intense femtosecond laser pulses provide the opportunity to explore the structural information of molecules. The field-free molecular alignment technique is an expedient tool for investigating the structural characteristics of linear molecules. The underlying physics of field-free alignment, showing the characteristic revival structure specific to molecular species, is clearly explained from the quantum-phase analysis of molecular rotational states. The anisotropic nature of molecules is shown from the harmonic polarization measurement performed with spatial interferometry. The multi-orbital characteristics of molecules are investigated using high-harmonic spectroscopy, applied to molecules of N2 and CO2. In the latter case the two-dimensional high-harmonic spectroscopy, implemented using a two-color laser field, is applied to distinguish harmonics from different orbitals. Molecular high-harmonic spectroscopy will open a new route to investigate ultrafast dynamics of molecules.
Cumming, Gordon R.
1970-01-01
Fitness testing of athletes can be subdivided into tests of body build, strength, aerobic power, and tests specific to the athletic event. World class athletes seem to fall into specific body types for the individual events. The top athlete usually has very little of the endomorphic characteristics and should be lean. Strength testing should be used more frequently as weight and isometric training techniques are used by many athletes and coaches without specific goals. The aerobic power of many national class athletes may be only 10-30 percent above that of the general population, and high values were found only in cyclists and distance runners. It is emphasized that the scores of fitness tests are specific for each test and do not necessarily correlate at all with athletic performance which is also specific. Despite this limitation, fitness tests do have a place in athletics and should be utilized more fully and with more understanding by coaches and athletes. Imagesp48-a PMID:20468546
Wu, Hao; Sears, Lindsay E; Coberley, Carter R; Pope, James E
2016-01-01
The aim of this study was to study the effects of overall well-being and well-being change on six supervisor-rated indicators of employee performance valued by organizations: overall performance, accountability, customer service, innovation, prosocial behavior, and self-development. The current study used two waves of well-being survey data collected over 2 years and supervisor performance ratings for 5691 employees. Ordinary least squares regression was conducted. Both well-being at baseline and two-year change in well-being were related to all six supervisor-rated performance dimensions, controlling for other employee characteristics. Overall well-being likely functioned as a resource enabling people to successfully perform across the specific areas highly valued by their company. Given this connection, well-being interventions could be used as a means to accomplish improved performance in dimensions that contribute to organizational performance.