Sample records for specific test procedures

  1. 40 CFR 600.111-93 - Test procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Test procedures. 600.111-93 Section... Model Year Automobiles-Test Procedures § 600.111-93 Test procedures. (a) The test procedures to be... loss portion of the test procedure may be omitted unless specifically required by the Administrator...

  2. 21 CFR 226.58 - Laboratory controls.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Laboratory controls. Laboratory controls shall include the establishment of adequate specifications and test... establishment of master records containing appropriate specifications and a description of the test procedures... necessary laboratory test procedures to check such specifications. (c) Assays which shall be made of...

  3. 40 CFR Appendix A to Part 75 - Specifications and Test Procedures

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Specifications and Test Procedures A... (CONTINUED) CONTINUOUS EMISSION MONITORING Pt. 75, App. A Appendix A to Part 75—Specifications and Test... concentration monitor and diluent gas monitor) will pass the relative accuracy test (see section 6 of this...

  4. 40 CFR 86.1506 - Equipment required and specifications; overview.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... specifications appear in §§ 86.1509 through 86.1511. (2) Fuel and analytical tests. Fuel requirements for idle... Test Procedures § 86.1506 Equipment required and specifications; overview. (a) This subpart contains procedures for performing idle exhaust emission tests on Otto-cycle heavy-duty engines and Otto-cycle light...

  5. 40 CFR 86.1506 - Equipment required and specifications; overview.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... specifications appear in §§ 86.1509 through 86.1511. (2) Fuel and analytical tests. Fuel requirements for idle... Test Procedures § 86.1506 Equipment required and specifications; overview. (a) This subpart contains procedures for performing idle exhaust emission tests on Otto-cycle heavy-duty engines and Otto-cycle light...

  6. 40 CFR 86.1506 - Equipment required and specifications; overview.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... specifications appear in §§ 86.1509 through 86.1511. (2) Fuel and analytical tests. Fuel requirements for idle... Test Procedures § 86.1506 Equipment required and specifications; overview. (a) This subpart contains procedures for performing idle exhaust emission tests on Otto-cycle heavy-duty engines and Otto-cycle light...

  7. 40 CFR 86.513 - Fuel and engine lubricant specifications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.513 Fuel and engine lubricant... of § 86.513—Gasoline Test Fuel Specifications Item Value Procedure 1 Distillation Range: 1. Initial... of § 86.513—Natural Gas Test Fuel Specifications Item Value 1 Methane, CH4 Minimum, 89.0 mole percent...

  8. 40 CFR Appendix A to Part 75 - Specifications and Test Procedures

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... appendix. RE = Expected average design removal efficiency of control equipment (%). 2.1.1.3Span Value(s... 40 Protection of Environment 17 2012-07-01 2012-07-01 false Specifications and Test Procedures A... (CONTINUED) CONTINUOUS EMISSION MONITORING Pt. 75, App. A Appendix A to Part 75—Specifications and Test...

  9. 40 CFR Appendix A to Part 75 - Specifications and Test Procedures

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... appendix. RE = Expected average design removal efficiency of control equipment (%). 2.1.1.3Span Value(s... 40 Protection of Environment 17 2013-07-01 2013-07-01 false Specifications and Test Procedures A... (CONTINUED) CONTINUOUS EMISSION MONITORING Pt. 75, App. A Appendix A to Part 75—Specifications and Test...

  10. Test equality between two binary screening tests with a confirmatory procedure restricted on screen positives.

    PubMed

    Lui, Kung-Jong; Chang, Kuang-Chao

    2015-01-01

    In studies of screening accuracy, we may commonly encounter the data in which a confirmatory procedure is administered to only those subjects with screen positives for ethical concerns. We focus our discussion on simultaneously testing equality of sensitivity and specificity between two binary screening tests when only subjects with screen positives receive the confirmatory procedure. We develop four asymptotic test procedures and one exact test procedure. We derive sample size calculation formula for a desired power of detecting a difference at a given nominal [Formula: see text]-level. We employ Monte Carlo simulation to evaluate the performance of these test procedures and the accuracy of the sample size calculation formula developed here in a variety of situations. Finally, we use the data obtained from a study of the prostate-specific-antigen test and digital rectal examination test on 949 Black men to illustrate the practical use of these test procedures and the sample size calculation formula.

  11. 40 CFR Appendix A to Part 75 - Specifications and Test Procedures

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-1b in section 2.1.1.1 of this appendix. RE = Expected average design removal efficiency of control... 40 Protection of Environment 16 2011-07-01 2011-07-01 false Specifications and Test Procedures A... (CONTINUED) CONTINUOUS EMISSION MONITORING Pt. 75, App. A Appendix A to Part 75—Specifications and Test...

  12. 46 CFR 164.009-15 - Test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 6 2014-10-01 2014-10-01 false Test procedure. 164.009-15 Section 164.009-15 Shipping...: SPECIFICATIONS AND APPROVAL MATERIALS Noncombustible Materials for Merchant Vessels § 164.009-15 Test procedure. (a) General. Paragraphs (b) through (k) of this section contain the test procedures for each material...

  13. 40 CFR 1065.715 - Natural gas.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PROCEDURES Engine Fluids, Test Fuels, Analytical Gases and Other Calibration Standards § 1065.715 Natural gas... specifications in the following table: Table 1 of § 1065.715—Test Fuel Specifications for Natural Gas Property....051 mol/mol. 1 Demonstrate compliance with fuel specifications based on the reference procedures in...

  14. Specific test and evaluation plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hays, W.H.

    1998-03-20

    The purpose of this Specific Test and Evaluation Plan (STEP) is to provide a detailed written plan for the systematic testing of modifications made to the 241-AX-B Valve Pit by the W-314 Project. The STEP develops the outline for test procedures that verify the system`s performance to the established Project design criteria. The STEP is a lower tier document based on the W-314 Test and Evaluation Plan (TEP). Testing includes Validations and Verifications (e.g., Commercial Grade Item Dedication activities), Factory Acceptance Tests (FATs), installation tests and inspections, Construction Acceptance Tests (CATs), Acceptance Test Procedures (ATPs), Pre-Operational Test Procedures (POTPs), andmore » Operational Test Procedures (OTPs). It should be noted that POTPs are not required for testing of the transfer line addition. The STEP will be utilized in conjunction with the TEP for verification and validation.« less

  15. 78 FR 14457 - Guidelines Establishing Test Procedures for the Analysis of Pollutants Under the Clean Water Act...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-06

    ... Establishing Test Procedures for the Analysis of Pollutants Under the Clean Water Act; Analysis and Sampling... for use as an alternative oil and grease method. Some comments were specific to the sampling...-side comparison using the specific procedures (e.g. sampling frequency, number of samples, QA/QC, and...

  16. Towards sensible toxicity testing for nanomaterials: proposal for the specification of test design.

    PubMed

    Potthoff, Annegret; Weil, Mirco; Meißner, Tobias; Kühnel, Dana

    2015-12-01

    During the last decade, nanomaterials (NM) were extensively tested for potential harmful effects towards humans and environmental organisms. However, a sound hazard assessment was so far hampered by uncertainties and a low comparability of test results. The reason for the low comparability is a high variation in the (1) type of NM tested with regard to raw material, size and shape and (2) procedures before and during the toxicity testing. This calls for tailored, nanomaterial-specific protocols. Here, a structured approach is proposed, intended to lead to test protocols not only tailored to specific types of nanomaterials, but also to respective test system for toxicity testing. There are existing standards on single procedures involving nanomaterials, however, not all relevant procedures are covered by standards. Hence, our approach offers a detailed way of weighting several plausible alternatives for e.g. sample preparation, in order to decide on the procedure most meaningful for a specific nanomaterial and toxicity test. A framework of several decision trees (DT) and flow charts to support testing of NM is proposed as a basis for further refinement and in-depth elaboration. DT and flow charts were drafted for (1) general procedure-physicochemical characterisation, (2) choice of test media, (3) decision on test scenario and application of NM to liquid media, (4) application of NM to the gas phase, (5) application of NM to soil and sediments, (6) dose metrics, (S1) definition of a nanomaterial, and (S2) dissolution. The applicability of the proposed approach was surveyed by using experimental data retrieved from studies on nanoscale CuO. This survey demonstrated the DT and flow charts to be a convenient tool to systematically decide upon test procedures and processes, and hence pose an important step towards harmonisation of NM testing.

  17. 40 CFR Appendix E to Part 52 - Performance Specifications and, Specification Test Procedures for Monitoring Systems for Effluent...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., Specification Test Procedures for Monitoring Systems for Effluent Stream Gas Volumetric Flow Rate E Appendix E... Stream Gas Volumetric Flow Rate 1. Principle and applicability. 1.1Principle. Effluent stream gas... method is applicable to subparts which require continuous gas volumetric flow rate measurement...

  18. 40 CFR Appendix E to Part 52 - Performance Specifications and, Specification Test Procedures for Monitoring Systems for Effluent...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., Specification Test Procedures for Monitoring Systems for Effluent Stream Gas Volumetric Flow Rate E Appendix E... Stream Gas Volumetric Flow Rate 1. Principle and applicability. 1.1Principle. Effluent stream gas... method is applicable to subparts which require continuous gas volumetric flow rate measurement...

  19. Project W-314 specific test and evaluation plan for AZ tank farm upgrades

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hays, W.H.

    1998-08-12

    The purpose of this Specific Test and Evaluation Plan (STEP) is to provide a detailed written plan for the systematic testing of modifications made by the addition of the SN-631 transfer line from the AZ-O1A pit to the AZ-02A pit by the W-314 Project. The STEP develops the outline for test procedures that verify the system`s performance to the established Project design criteria. The STEP is a lower tier document based on the W-314 Test and Evaluation P1 an (TEP). Testing includes Validations and Verifications (e.g., Commercial Grade Item Dedication activities, etc), Factory Tests and Inspections (FTIs), installation tests andmore » inspections, Construction Tests and Inspections (CTIs), Acceptance Test Procedures (ATPs), Pre-Operational Test Procedures (POTPs), and Operational Test Procedures (OTPs). The STEP will be utilized in conjunction with the TEP for verification and validation.« less

  20. Project W-314 specific test and evaluation plan for transfer line SN-633 (241-AX-B to 241-AY-02A)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hays, W.H.

    1998-03-20

    The purpose of this Specific Test and Evaluation Plan (STEP) is to provide a detailed written plan for the systematic testing of modifications made by the addition of the SN-633 transfer line by the W-314 Project. The STEP develops the outline for test procedures that verify the system`s performance to the established Project design criteria. The STEP is a lower tier document based on the W-314 Test and Evaluation Plan (TEP). This STEP encompasses all testing activities required to demonstrate compliance to the project design criteria as it relates to the addition of transfer line SN-633. The Project Design Specificationsmore » (PDS) identify the specific testing activities required for the Project. Testing includes Validations and Verifications (e.g., Commercial Grade Item Dedication activities), Factory Acceptance Tests (FATs), installation tests and inspections, Construction Acceptance Tests (CATs), Acceptance Test Procedures (ATPs), Pre-Operational Test Procedures (POTPs), and Operational Test Procedures (OTPs). It should be noted that POTPs are not required for testing of the transfer line addition. The STEP will be utilized in conjunction with the TEP for verification and validation.« less

  1. End-of-fabrication CMOS process monitor

    NASA Technical Reports Server (NTRS)

    Buehler, M. G.; Allen, R. A.; Blaes, B. R.; Hannaman, D. J.; Lieneweg, U.; Lin, Y.-S.; Sayah, H. R.

    1990-01-01

    A set of test 'modules' for verifying the quality of a complementary metal oxide semiconductor (CMOS) process at the end of the wafer fabrication is documented. By electrical testing of specific structures, over thirty parameters are collected characterizing interconnects, dielectrics, contacts, transistors, and inverters. Each test module contains a specification of its purpose, the layout of the test structure, the test procedures, the data reduction algorithms, and exemplary results obtained from 3-, 2-, or 1.6-micrometer CMOS/bulk processes. The document is intended to establish standard process qualification procedures for Application Specific Integrated Circuits (ASIC's).

  2. 40 CFR 63.9622 - What test methods and other procedures must I use to establish and demonstrate initial compliance...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-specific operating limits according to the procedures in paragraphs (a)(1) through (3) of this section. (1... establish site-specific operating limits according to the procedures in paragraphs (b)(1) and (2) of this... site-specific operating limit according to the procedures in paragraphs (c)(1) or (2) of this section...

  3. 40 CFR 63.9622 - What test methods and other procedures must I use to establish and demonstrate initial compliance...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...-specific operating limits according to the procedures in paragraphs (a)(1) through (3) of this section. (1... establish site-specific operating limits according to the procedures in paragraphs (b)(1) and (2) of this... site-specific operating limit according to the procedures in paragraphs (c)(1) or (2) of this section...

  4. 40 CFR 63.9622 - What test methods and other procedures must I use to establish and demonstrate initial compliance...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...-specific operating limits according to the procedures in paragraphs (a)(1) through (3) of this section. (1... establish site-specific operating limits according to the procedures in paragraphs (b)(1) and (2) of this... site-specific operating limit according to the procedures in paragraphs (c)(1) or (2) of this section...

  5. 40 CFR 63.9622 - What test methods and other procedures must I use to establish and demonstrate initial compliance...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...-specific operating limits according to the procedures in paragraphs (a)(1) through (3) of this section. (1... establish site-specific operating limits according to the procedures in paragraphs (b)(1) and (2) of this... site-specific operating limit according to the procedures in paragraphs (c)(1) or (2) of this section...

  6. 40 CFR 63.9622 - What test methods and other procedures must I use to establish and demonstrate initial compliance...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-specific operating limits according to the procedures in paragraphs (a)(1) through (3) of this section. (1... establish site-specific operating limits according to the procedures in paragraphs (b)(1) and (2) of this... site-specific operating limit according to the procedures in paragraphs (c)(1) or (2) of this section...

  7. Development of electrical test procedures for qualification of spacecraft against EID. Volume 2: Review and specification of test procedures

    NASA Technical Reports Server (NTRS)

    Wilkenfeld, J. M.; Harlacher, B. L.; Mathews, D.

    1982-01-01

    A combined experimental and analytical program to develop system electrical test procedures for the qualification of spacecraft against damage produced by space-electron-induced discharges (EID) occurring on spacecraft dielectric outer surfaces is described. A review and critical evaluation of possible approaches to qualify spacecraft against space electron-induced discharges (EID) is presented. A variety of possible schemes to simulate EID electromagnetic effects produced in spacecraft was studied. These techniques form the principal element of a provisional, recommended set of test procedures for the EID qualification spacecraft. Significant gaps in our knowledge about EID which impact the final specification of an electrical test to qualify spacecraft against EID are also identified.

  8. Notes on testing non-inferiority under the partial verification design with a confirmatory procedure limited to screen positives.

    PubMed

    Lui, Kung-Jong

    2012-05-01

    When a new test with fewer invasions or less expenses to administer than the traditional test is developed, we may be interested in testing whether the former is non-inferior to the latter with respect to test accuracy. We define non-inferiority via both the odds ratio (OR) of correctly identifying a case and the OR of correctly identifying a non-case between two tests under comparison. We focus our discussion on testing the non-inferiority of a new screening test to a traditional screening test when a confirmatory procedure is performed only on patients with screen positives. On the basis of well-established methods for paired-sample data, we derive an asymptotic test procedure and an exact test procedure with respect to the two ORs defined here. Using Monte Carlo simulation, we evaluate the performance of these test procedures in a variety of situations. We note that the test procedures proposed here can also be applicable if we are interested in testing non-inferiority with respect to the ratio of sensitivities and the ratio of specificities. We discuss interval estimation of these ORs and sample size calculation based on the asymptotic test procedure considered here. We use the data taken from a study of the prostate-specific-antigen (PSA) test and the digital rectal examination (DRE) test to illustrate the practical use of these test procedures, interval estimators and sample size calculation formula. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Assessment of Individuals with Hearing Impairments: Equity in Testing Procedures and Accommodations.

    ERIC Educational Resources Information Center

    Gordon, Robin Perkins; And Others

    1996-01-01

    Reviews research related to testing procedures and accommodations for individuals with hearing impairments, with a special focus on the specific issues that may influence standardized psychological, educational, and work-related testing procedures for people with hearing impairments. Includes considerations for professionals conducting assessments…

  10. Towards sensible toxicity testing for nanomaterials: proposal for the specification of test design

    NASA Astrophysics Data System (ADS)

    Potthoff, Annegret; Weil, Mirco; Meißner, Tobias; Kühnel, Dana

    2015-12-01

    During the last decade, nanomaterials (NM) were extensively tested for potential harmful effects towards humans and environmental organisms. However, a sound hazard assessment was so far hampered by uncertainties and a low comparability of test results. The reason for the low comparability is a high variation in the (1) type of NM tested with regard to raw material, size and shape and (2) procedures before and during the toxicity testing. This calls for tailored, nanomaterial-specific protocols. Here, a structured approach is proposed, intended to lead to test protocols not only tailored to specific types of nanomaterials, but also to respective test system for toxicity testing. There are existing standards on single procedures involving nanomaterials, however, not all relevant procedures are covered by standards. Hence, our approach offers a detailed way of weighting several plausible alternatives for e.g. sample preparation, in order to decide on the procedure most meaningful for a specific nanomaterial and toxicity test. A framework of several decision trees (DT) and flow charts to support testing of NM is proposed as a basis for further refinement and in-depth elaboration. DT and flow charts were drafted for (1) general procedure—physicochemical characterisation, (2) choice of test media, (3) decision on test scenario and application of NM to liquid media, (4) application of NM to the gas phase, (5) application of NM to soil and sediments, (6) dose metrics, (S1) definition of a nanomaterial, and (S2) dissolution. The applicability of the proposed approach was surveyed by using experimental data retrieved from studies on nanoscale CuO. This survey demonstrated the DT and flow charts to be a convenient tool to systematically decide upon test procedures and processes, and hence pose an important step towards harmonisation of NM testing.

  11. ENRAF Series 854 Advanced Technology Gauge (ATG) with SPU ll Card for Leak Detector Use Acceptance Test Procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SMITH, S.G.

    1999-08-13

    This procedure checks the Enraf gauge received at Hanford is completely functional and has received no shipping damage. This procedure does not certify the gauge operation. The manufacturer certifies gauge operation. This procedure provides acceptance testing for Enraf Series 854 level gauges used to detect leaks in Hanford Waste Storage Tank annuli. The test will verify that the gauge functions according to the manufacturer's instructions and specifications and is properly setup prior to being delivered to the tank farm area. This ATP does not set up the gauge for any specific tank, but is generalized to permit testing the gaugemore » prior to installation package preparation.« less

  12. Procedure for contact electrical resistance measurements as developed for use at Sandia National Laboratories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Finch, J.L.

    1994-06-01

    Military Specifications call out general procedures and guidelines for conducting contact resistance measurements on chemical conversion coated panels. This paper deals with a test procedure developed at Sandia National Laboratories used to conduct contact electrical resistance on non-chromated conversion coated test panels. MIL-C-81706 {open_quotes}Chemical Conversion Materials For Coating Aluminum and Aluminum Alloys{close_quotes} was the reference specification used for guidance.

  13. ENRAF Series 854 Advanced Technology Gauge (ATG) Acceptance Test Procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    HUBER, J.H.

    1999-08-17

    This procedure provides acceptance testing for Enraf Series 854 level gauges used to monitor levels in Hanford Waste Storage Tanks. The test will verify that the gauge functions according to the manufacturer's instructions and specifications and is properly setup prior to being delivered to the tank farm area. This ATP does not set up the gauge for any specific tank, but is generalized to permit testing the gauge prior to installation package preparation.

  14. The Standardization of Tests: Criteria and Criticisms

    ERIC Educational Resources Information Center

    Weiner, Paul S.; Hoock, William C.

    1973-01-01

    Following a review of the procedures involved in the establishment of norms for standardized tests, the specific procedures used to establish norms for three tests commonly used in speech and language pathology are critically examined. (LS)

  15. 75 FR 52892 - Energy Conservation Program for Consumer Products: Test Procedures for Residential Water Heaters...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-30

    .... Treatment of Fossil-Fuel Consumption in Existing Test Procedures for Fossil-Fuel Vented Heaters 2. Specific.... Proposed Test Procedure Amendments for Pool Heaters 1. Treatment of Fossil-Fuel Consumption in Existing.... Fossil-fuel standby mode and off mode energy use is already integrated into the vented [[Page 52895...

  16. 78 FR 35898 - Decision and Order Granting a Waiver to Samsung From the Department of Energy Residential...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-14

    ... Refrigerator-Freezer Test Procedures AGENCY: Office of Energy Efficiency and Renewable Energy, Department of... from the DOE electric refrigerator and refrigerator-freezer test procedures for specific basic models set forth in its petition for waiver. In its petition, Samsung provides an alternate test procedure...

  17. 78 FR 35901 - Decision and Order Granting a Waiver to Samsung From the Department of Energy Residential...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-14

    ... Refrigerator-Freezer Test Procedures AGENCY: Office of Energy Efficiency and Renewable Energy, Department of... from the DOE electric refrigerator and refrigerator-freezer test procedures for specific basic models set forth in its petition for waiver. In its petition, Samsung provides an alternate test procedure...

  18. 40 CFR 600.107-08 - Fuel specifications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Exhaust Emission Test Procedures § 600.107-08 Fuel specifications. (a) The test fuel specifications for... given in paragraph (b) of this section. (b)(1) Diesel test fuel used for cold temperature FTP testing... alternative fuel for cold temperature FTP testing. (c) Test fuels representing fuel types for which there are...

  19. 40 CFR 600.107-08 - Fuel specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Exhaust Emission Test Procedures § 600.107-08 Fuel specifications. (a) The test fuel specifications for... given in paragraph (b) of this section. (b)(1) Diesel test fuel used for cold temperature FTP testing... alternative fuel for cold temperature FTP testing. (c) Test fuels representing fuel types for which there are...

  20. 40 CFR 600.107-08 - Fuel specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Exhaust Emission Test Procedures § 600.107-08 Fuel specifications. (a) The test fuel specifications for... given in paragraph (b) of this section. (b)(1) Diesel test fuel used for cold temperature FTP testing... alternative fuel for cold temperature FTP testing. (c) Test fuels representing fuel types for which there are...

  1. Certification of highly complex safety-related systems.

    PubMed

    Reinert, D; Schaefer, M

    1999-01-01

    The BIA has now 15 years of experience with the certification of complex electronic systems for safety-related applications in the machinery sector. Using the example of machining centres this presentation will show the systematic procedure for verifying and validating control systems using Application Specific Integrated Circuits (ASICs) and microcomputers for safety functions. One section will describe the control structure of machining centres with control systems using "integrated safety." A diverse redundant architecture combined with crossmonitoring and forced dynamization is explained. In the main section the steps of the systematic certification procedure are explained showing some results of the certification of drilling machines. Specification reviews, design reviews with test case specification, statistical analysis, and walk-throughs are the analytical measures in the testing process. Systematic tests based on the test case specification, Electro Magnetic Interference (EMI), and environmental testing, and site acceptance tests on the machines are the testing measures for validation. A complex software driven system is always undergoing modification. Most of the changes are not safety-relevant but this has to be proven. A systematic procedure for certifying software modifications is presented in the last section of the paper.

  2. 40 CFR 86.134-96 - Running loss test.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... running loss test procedure as approved for a specific vehicle. (4) High-altitude testing. For testing... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Running loss test. 86.134-96 Section... Heavy-Duty Vehicles; Test Procedures § 86.134-96 Running loss test. (a) Overview. Gasoline- and methanol...

  3. 77 FR 49063 - Energy Conservation Program: Test Procedures for Residential Dishwashers and Cooking Products

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-15

    ...The U.S. Department of Energy (DOE) proposes to amend its test procedures for residential dishwashers to update certain obsolete dishware, flatware and food items, make minor amendments to the definition of the normal cycle, and update the ambient temperature and preconditioning requirements as well as the industry test method referenced in DOE's test procedure. DOE also proposes to add water pressure, drain height, rack position, loading, rinse aid container, and soil preparation specifications to the dishwasher test procedure. DOE additionally proposes to amend the test procedures for both dishwashers and conventional cooking products for the measurement of energy use in fan-only mode.

  4. 40 CFR 600.107-93 - Fuel specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and Later Model Year Automobiles-Test Procedures § 600.107-93 Fuel specifications. (a) The test fuel... chapter. (c) The test fuel specifications for methanol fuel used in Otto-cycle automobiles are given in § 86.113(a) (3) and (4) of this chapter. (d) The test fuel specifications for methanol fuel used in...

  5. 75 FR 8526 - Procedures for Transportation Workplace Drug and Alcohol Testing Programs

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-25

    ... regarding the interim final rule (IFR) procedures for the use of a new alcohol screening device (ASD) which... for an employer to utilize a specific ASD to conduct required DOT alcohol tests, the device must (a... model specifications, (b) be published by NHTSA in the Federal Register on their most current ASD CPL...

  6. 40 CFR 86.1427 - Certification Short Test procedure; overview.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... loaded modes. Specific conditions defined by this test procedure include fuel characteristics, ambient... CO fuel, a moderate temperature test with Cold CO fuel, and a warm temperature test with FTP Otto-cycle test fuel, as described in table O-96-1 of § 86.1430. The manufacturer must complete testing for...

  7. 40 CFR 86.1427 - Certification Short Test procedure; overview.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... loaded modes. Specific conditions defined by this test procedure include fuel characteristics, ambient... CO fuel, a moderate temperature test with Cold CO fuel, and a warm temperature test with FTP Otto-cycle test fuel, as described in table O-96-1 of § 86.1430. The manufacturer must complete testing for...

  8. 40 CFR 86.1427 - Certification Short Test procedure; overview.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... loaded modes. Specific conditions defined by this test procedure include fuel characteristics, ambient... CO fuel, a moderate temperature test with Cold CO fuel, and a warm temperature test with FTP Otto-cycle test fuel, as described in table O-96-1 of § 86.1430. The manufacturer must complete testing for...

  9. 40 CFR 86.1427 - Certification Short Test procedure; overview.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... loaded modes. Specific conditions defined by this test procedure include fuel characteristics, ambient... CO fuel, a moderate temperature test with Cold CO fuel, and a warm temperature test with FTP Otto-cycle test fuel, as described in table O-96-1 of § 86.1430. The manufacturer must complete testing for...

  10. Detailed Test Plan Redundant Sensor Strapdown IMU Evaluation Program

    NASA Technical Reports Server (NTRS)

    Hartwell, T.; Miyatake, Y.; Wedekind, D. E.

    1971-01-01

    The test plan for a redundant sensor strapdown inertial measuring unit evaluation program is presented. The subjects discussed are: (1) test philosophy and limitations, (2) test sequence, (3) equipment specifications, (4) general operating procedures, (5) calibration procedures, (6) alignment test phase, and (7) navigation test phase. The data and analysis requirements are analyzed.

  11. Small Optics Laser Damage Test Procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wolfe, Justin

    2017-10-19

    This specification defines the requirements and procedure for laser damage testing of coatings and bare surfaces designated for small optics in the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL).

  12. 40 CFR 1066.101 - Overview.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PROCEDURES Equipment, Measurement Instruments, Fuel, and Analytical Gas Specifications § 1066.101 Overview. (a) This subpart addresses equipment related to emission testing, as well as test fuels and... specifications for fuels, engine fluids, and analytical gases; these specifications apply for testing under this...

  13. 7 CFR 51.3417 - Optional test for specific gravity.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Optional test for specific gravity. 51.3417 Section 51... specific gravity. Tests to determine specific gravity shall be made in accordance with the procedures set.... The specific gravity for any lot of potatoes shall be the average of at least 3 corrected readings on...

  14. 7 CFR 51.3417 - Optional test for specific gravity.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Optional test for specific gravity. 51.3417 Section 51... specific gravity. Tests to determine specific gravity shall be made in accordance with the procedures set.... The specific gravity for any lot of potatoes shall be the average of at least 3 corrected readings on...

  15. Balancing Flexible Constraints and Measurement Precision in Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Moyer, Eric L.; Galindo, Jennifer L.; Dodd, Barbara G.

    2012-01-01

    Managing test specifications--both multiple nonstatistical constraints and flexibly defined constraints--has become an important part of designing item selection procedures for computerized adaptive tests (CATs) in achievement testing. This study compared the effectiveness of three procedures: constrained CAT, flexible modified constrained CAT,…

  16. 40 CFR 1065.720 - Liquefied petroleum gas.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... CONTROLS ENGINE-TESTING PROCEDURES Engine Fluids, Test Fuels, Analytical Gases and Other Calibration....720—Test Fuel Specifications for Liquefied Petroleum Gas Property Value Reference procedure 1 Propane... methods yield different results, use the results from ASTM D1267. 3 The test fuel must not yield a...

  17. 40 CFR 600.107-78 - Fuel specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Exhaust Emission Regulations for 1978 and Later Model Year Automobiles-Test Procedures § 600.107-78 Fuel specifications. (a) The test fuel specifications for gasoline-fueled automobiles are given in paragraph (a)(1) of § 86.113 of this chapter. (b) The test fuel specifications for diesel automobiles are given in...

  18. 40 CFR Appendix B to Part 75 - Quality Assurance and Quality Control Procedures

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... in section 2.3 of this appendix and the Hg emission tests described in §§ 75.81(c) and 75.81(d)(4). 1.2Specific Requirements for Continuous Emissions Monitoring Systems 1.2.1Calibration Error Test and Linearity Check Procedures Keep a written record of the procedures used for daily calibration error tests and...

  19. 40 CFR 86.113-04 - Fuel specifications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Heavy-Duty Vehicles; Test Procedures § 86.113-04 Fuel specifications. This section includes text that... exhaust and evaporative emission testing: Table 1 of § 86.113-04—Test Fuel Specifications for Gasoline... method. (2) Manufacturers may use California test fuels, as follows: (i) For model year 2014 and earlier...

  20. 40 CFR 86.213-11 - Fuel specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.213-11 Fuel specifications. (a) Gasoline... the text in this section follows: Table—Cold CO Fuel Specifications Item ASTM test Cold CO low octane.... Diesel test fuel used for cold temperature FTP testing under part 600 of this chapter must be a winter...

  1. 40 CFR 86.213-11 - Fuel specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.213-11 Fuel specifications. (a) Gasoline... the text in this section follows: Table—Cold CO Fuel Specifications Item ASTM test Cold CO low octane.... Diesel test fuel used for cold temperature FTP testing under part 600 of this chapter must be a winter...

  2. 40 CFR 86.213-11 - Fuel specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.213-11 Fuel specifications. (a) Gasoline... the text in this section follows: Table—Cold CO Fuel Specifications Item ASTM test Cold CO low octane.... Diesel test fuel used for cold temperature FTP testing under part 600 of this chapter must be a winter...

  3. 40 CFR 86.213-11 - Fuel specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.213-11 Fuel specifications. (a) Gasoline... the text in this section follows: Table—Cold CO Fuel Specifications Item ASTM test Cold CO low octane.... Diesel test fuel used for cold temperature FTP testing under part 600 of this chapter must be a winter...

  4. Assessment in Counseling: A Guide to the Use of Psychological Assessment Procedures. Third Edition.

    ERIC Educational Resources Information Center

    Hood, Albert B.; Johnson, Richard W.

    This book presents information about various psychological assessment procedures that are specifically relevant for practicing counselors. It deals with the use of assessment procedures in the counseling process and emphasizes the selection, interpretation, and communication of psychological test results. The importance of integrating test results…

  5. 40 CFR 1065.901 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....901 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Field Testing and Portable Emission Measurement Systems § 1065.901...-specific emissions using portable emission measurement systems (PEMS). These procedures are designed...

  6. 40 CFR 1065.720 - Liquefied petroleum gas.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... CONTROLS ENGINE-TESTING PROCEDURES Engine Fluids, Test Fuels, Analytical Gases and Other Calibration....720—Test Fuel Specifications for Liquefied Petroleum Gas Item Value Reference procedure 1 Propane... test fuel must not yield a persistent oil ring when you add 0.3 ml of solvent residue mixture to a...

  7. 40 CFR 1065.720 - Liquefied petroleum gas.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... CONTROLS ENGINE-TESTING PROCEDURES Engine Fluids, Test Fuels, Analytical Gases and Other Calibration....720—Test Fuel Specifications for Liquefied Petroleum Gas Item Value Reference procedure 1 Propane... test fuel must not yield a persistent oil ring when you add 0.3 ml of solvent residue mixture to a...

  8. 40 CFR 1065.720 - Liquefied petroleum gas.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... CONTROLS ENGINE-TESTING PROCEDURES Engine Fluids, Test Fuels, Analytical Gases and Other Calibration....720—Test Fuel Specifications for Liquefied Petroleum Gas Item Value Reference procedure 1 Propane... test fuel must not yield a persistent oil ring when you add 0.3 ml of solvent residue mixture to a...

  9. 40 CFR 80.177 - Certification test fuels for use with the alternative test procedures and standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Certification test fuels for use with... Detergent Gasoline § 80.177 Certification test fuels for use with the alternative test procedures and standards. (a) General requirements. This section provides specifications for the test fuels required in...

  10. 40 CFR 63.7824 - What test methods and other procedures must I use to establish and demonstrate initial compliance...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... establish site-specific operating limits according to the procedures in paragraphs (b)(1) and (2) of this.... (3) Establish revised operating limits according to the applicable procedures in paragraphs (a) and... 40 Protection of Environment 14 2014-07-01 2014-07-01 false What test methods and other procedures...

  11. 40 CFR 63.7824 - What test methods and other procedures must I use to establish and demonstrate initial compliance...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... establish site-specific operating limits according to the procedures in paragraphs (b)(1) and (2) of this.... (3) Establish revised operating limits according to the applicable procedures in paragraphs (a) and... 40 Protection of Environment 14 2012-07-01 2011-07-01 true What test methods and other procedures...

  12. Multiple hypotheses testing based on ordered p values--a historical survey with applications to medical research.

    PubMed

    Hommel, Gerhard; Bretz, Frank; Maurer, Willi

    2011-07-01

    Global tests and multiple test procedures are often based on ordered p values. Such procedures are available for arbitrary dependence structures as well as for specific dependence assumptions of the test statistics. Most of these procedures have been considered as global tests. Multiple test procedures can be obtained by applying the closure principle in order to control the familywise error rate, or by using the false discovery rate as a criterion for type I error rate control. We provide an overview and present examples showing the importance of these procedures in medical research. Finally, we discuss modifications when different weights for the hypotheses of interest are chosen.

  13. 40 CFR 63.7521 - What fuel analyses, fuel specification, and procedures must I use?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... fuel specification analyses for hydrogen sulfide and mercury according to the procedures in paragraphs... 40 Protection of Environment 13 2011-07-01 2011-07-01 false What fuel analyses, fuel specification..., Commercial, and Institutional Boilers and Process Heaters Testing, Fuel Analyses, and Initial Compliance...

  14. 40 CFR 600.107-93 - Fuel specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Exhaust Emission Regulations for 1978 and Later Model Year Automobiles-Test Procedures § 600.107-93 Fuel specifications. (a) The test fuel specifications for gasoline-fueled automobiles are given in § 86.113(a) (1) and (2) of this chapter. (b) The test fuel specifications for diesel-fueled automobiles are given in § 86...

  15. 40 CFR 600.107-78 - Fuel specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and Later Model Year Automobiles-Test Procedures § 600.107-78 Fuel specifications. (a) The test fuel... test fuel specifications for diesel automobiles are given in paragraphs (b) (1) and (2) of § 86.113 of... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Fuel specifications. 600.107-78...

  16. 40 CFR 1060.205 - What must I include in my application?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... procedures you used (see § 1060.501). (d) List the specifications of the test fuel to show that it falls... the application (including the test procedures, test parameters, and test fuels) to show you meet the... certification for gasoline or some other fuel type. List each distinguishable configuration in the emission...

  17. 40 CFR 1060.205 - What must I include in my application?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... procedures you used (see § 1060.501). (d) List the specifications of the test fuel to show that it falls... the application (including the test procedures, test parameters, and test fuels) to show you meet the... certification for gasoline or some other fuel type. List each distinguishable configuration in the emission...

  18. 40 CFR 1060.205 - What must I include in my application?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... procedures you used (see § 1060.501). (d) List the specifications of the test fuel to show that it falls... the application (including the test procedures, test parameters, and test fuels) to show you meet the... certification for gasoline or some other fuel type. List each distinguishable configuration in the emission...

  19. 40 CFR 1060.205 - What must I include in my application?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... procedures you used (see § 1060.501). (d) List the specifications of the test fuel to show that it falls... the application (including the test procedures, test parameters, and test fuels) to show you meet the... certification for gasoline or some other fuel type. List each distinguishable configuration in the emission...

  20. 40 CFR 1060.205 - What must I include in my application?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... procedures you used (see § 1060.501). (d) List the specifications of the test fuel to show that it falls... the application (including the test procedures, test parameters, and test fuels) to show you meet the... certification for gasoline or some other fuel type. List each distinguishable configuration in the emission...

  1. 46 CFR 164.018-11 - Approval tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... the following test methods described in Federal Specification L-S-300: (1) Test conditions. (2) Test... sharp knife from each corner to the corner diagonally opposite so that an “X” is formed. The cuts must...— (1) The L-S-300 procedure for measuring reflective intensity; or (2) The procedure for measuring...

  2. 46 CFR 164.018-11 - Approval tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the following test methods described in Federal Specification L-S-300: (1) Test conditions. (2) Test... sharp knife from each corner to the corner diagonally opposite so that an “X” is formed. The cuts must...— (1) The L-S-300 procedure for measuring reflective intensity; or (2) The procedure for measuring...

  3. 46 CFR 164.018-11 - Approval tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... the following test methods described in Federal Specification L-S-300: (1) Test conditions. (2) Test... sharp knife from each corner to the corner diagonally opposite so that an “X” is formed. The cuts must...— (1) The L-S-300 procedure for measuring reflective intensity; or (2) The procedure for measuring...

  4. 46 CFR 164.018-11 - Approval tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... the following test methods described in Federal Specification L-S-300: (1) Test conditions. (2) Test... sharp knife from each corner to the corner diagonally opposite so that an “X” is formed. The cuts must...— (1) The L-S-300 procedure for measuring reflective intensity; or (2) The procedure for measuring...

  5. 46 CFR 164.018-11 - Approval tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... the following test methods described in Federal Specification L-S-300: (1) Test conditions. (2) Test... sharp knife from each corner to the corner diagonally opposite so that an “X” is formed. The cuts must...— (1) The L-S-300 procedure for measuring reflective intensity; or (2) The procedure for measuring...

  6. 40 CFR 90.417 - Fuel flow measurement specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Fuel flow measurement specifications... Gaseous Exhaust Test Procedures § 90.417 Fuel flow measurement specifications. (a) Fuel flow measurement is required only for raw testing. Fuel flow is allowed for dilute testing. (b) The fuel flow...

  7. Diagnosis of food allergies: the impact of oral food challenge testing.

    PubMed

    Ito, Komei

    2013-01-01

    A diagnosis of food allergies should be made based on the observation of allergic symptoms following the intake of suspected foods and the presence of allergen-specific IgE antibodies. The oral food challenge (OFC) test is the most reliable clinical procedure for diagnosing food allergies. Specific IgE testing of allergen components as well as classical crude allergen extracts helps to make a more specific diagnosis of food allergies. The Japanese Society of Pediatric Allergy and Clinical Immunology issued the 'Japanese Pediatric Guideline for Food Allergy 2012' to provide information regarding the standardized diagnosis and management of food allergies. This review summarizes recent progress in the diagnosis of food allergies, focusing on the use of specific IgE tests and the OFC procedure in accordance with the Japanese guidelines.

  8. Hypothesis tests for stratified mark-specific proportional hazards models with missing covariates, with application to HIV vaccine efficacy trials.

    PubMed

    Sun, Yanqing; Qi, Li; Yang, Guangren; Gilbert, Peter B

    2018-05-01

    This article develops hypothesis testing procedures for the stratified mark-specific proportional hazards model with missing covariates where the baseline functions may vary with strata. The mark-specific proportional hazards model has been studied to evaluate mark-specific relative risks where the mark is the genetic distance of an infecting HIV sequence to an HIV sequence represented inside the vaccine. This research is motivated by analyzing the RV144 phase 3 HIV vaccine efficacy trial, to understand associations of immune response biomarkers on the mark-specific hazard of HIV infection, where the biomarkers are sampled via a two-phase sampling nested case-control design. We test whether the mark-specific relative risks are unity and how they change with the mark. The developed procedures enable assessment of whether risk of HIV infection with HIV variants close or far from the vaccine sequence are modified by immune responses induced by the HIV vaccine; this question is interesting because vaccine protection occurs through immune responses directed at specific HIV sequences. The test statistics are constructed based on augmented inverse probability weighted complete-case estimators. The asymptotic properties and finite-sample performances of the testing procedures are investigated, demonstrating double-robustness and effectiveness of the predictive auxiliaries to recover efficiency. The finite-sample performance of the proposed tests are examined through a comprehensive simulation study. The methods are applied to the RV144 trial. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. 40 CFR 86.113-94 - Fuel specifications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Heavy-Duty Vehicles; Test Procedures § 86.113-94 Fuel specifications. (a) [Reserved] (b) Petroleum diesel test fuel. (1) The petroleum fuels employed for testing diesel vehicles shall be clean and bright... test fuel is commercially available. (ii) Information acceptable to the Administrator is provided to...

  10. 21 CFR 660.26 - Specificity tests and avidity tests.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Specificity tests and avidity tests. 660.26 Section 660.26 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... using test procedures approved by the Director, Center for Biologics Evaluation and Research. [53 FR...

  11. 40 CFR 86.113-07 - Fuel specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Heavy-Duty Vehicles; Test Procedures § 86.113-07 Fuel specifications. Section 86.113-07 includes text... that incorporate sulfur-sensitive technologies, the manufacturer may test the vehicle using a test fuel...., certified to California and EPA standards), the manufacturer may test the vehicle using a test fuel whose...

  12. 40 CFR 86.113-07 - Fuel specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Heavy-Duty Vehicles; Test Procedures § 86.113-07 Fuel specifications. Section 86.113-07 includes text... that incorporate sulfur-sensitive technologies, the manufacturer may test the vehicle using a test fuel...., certified to California and EPA standards), the manufacturer may test the vehicle using a test fuel whose...

  13. 40 CFR 86.113-07 - Fuel specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Heavy-Duty Vehicles; Test Procedures § 86.113-07 Fuel specifications. Section 86.113-07 includes text... that incorporate sulfur-sensitive technologies, the manufacturer may test the vehicle using a test fuel...., certified to California and EPA standards), the manufacturer may test the vehicle using a test fuel whose...

  14. 40 CFR 86.113-07 - Fuel specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Heavy-Duty Vehicles; Test Procedures § 86.113-07 Fuel specifications. Section 86.113-07 includes text... that incorporate sulfur-sensitive technologies, the manufacturer may test the vehicle using a test fuel...., certified to California and EPA standards), the manufacturer may test the vehicle using a test fuel whose...

  15. Sequence-specific procedural learning deficits in children with specific language impairment.

    PubMed

    Hsu, Hsinjen Julie; Bishop, Dorothy V M

    2014-05-01

    This study tested the procedural deficit hypothesis of specific language impairment (SLI) by comparing children's performance in two motor procedural learning tasks and an implicit verbal sequence learning task. Participants were 7- to 11-year-old children with SLI (n = 48), typically developing age-matched children (n = 20) and younger typically developing children matched for receptive grammar (n = 28). In a serial reaction time task, the children with SLI performed at the same level as the grammar-matched children, but poorer than age-matched controls in learning motor sequences. When tested with a motor procedural learning task that did not involve learning sequential relationships between discrete elements (i.e. pursuit rotor), the children with SLI performed comparably with age-matched children and better than younger grammar-matched controls. In addition, poor implicit learning of word sequences in a verbal memory task (the Hebb effect) was found in the children with SLI. Together, these findings suggest that SLI might be characterized by deficits in learning sequence-specific information, rather than generally weak procedural learning. © 2014 The Authors. Developmental Science Published by John Wiley & Sons Ltd.

  16. Flat-panel cone-beam CT: a novel imaging technology for image-guided procedures

    NASA Astrophysics Data System (ADS)

    Siewerdsen, Jeffrey H.; Jaffray, David A.; Edmundson, Gregory K.; Sanders, W. P.; Wong, John W.; Martinez, Alvaro A.

    2001-05-01

    The use of flat-panel imagers for cone-beam CT signals the emergence of an attractive technology for volumetric imaging. Recent investigations demonstrate volume images with high spatial resolution and soft-tissue visibility and point to a number of logistical characteristics (e.g., open geometry, volume acquisition in a single rotation about the patient, and separation of the imaging and patient support structures) that are attractive to a broad spectrum of applications. Considering application to image-guided (IG) procedures - specifically IG therapies - this paper examines the performance of flat-panel cone-beam CT in relation to numerous constraints and requirements, including time (i.e., speed of image acquisition), dose, and field-of-view. The imaging and guidance performance of a prototype flat panel cone-beam CT system is investigated through the construction of procedure-specific tasks that test the influence of image artifacts (e.g., x-ray scatter and beam-hardening) and volumetric imaging performance (e.g., 3D spatial resolution, noise, and contrast) - taking two specific examples in IG brachytherapy and IG vertebroplasty. For IG brachytherapy, a procedure-specific task is constructed which tests the performance of flat-panel cone-beam CT in measuring the volumetric distribution of Pd-103 permanent implant seeds in relation to neighboring bone and soft-tissue structures in a pelvis phantom. For IG interventional procedures, a procedure-specific task is constructed in the context of vertebroplasty performed on a cadaverized ovine spine, demonstrating the volumetric image quality in pre-, intra-, and post-therapeutic images of the region of interest and testing the performance of the system in measuring the volumetric distribution of bone cement (PMMA) relative to surrounding spinal anatomy. Each of these tasks highlights numerous promising and challenging aspects of flat-panel cone-beam CT applied to IG procedures.

  17. NOAO testing procedures for large optics

    NASA Astrophysics Data System (ADS)

    Stepp, Larry M.; Poczulp, Gary A.; Pearson, Earl T.; Roddier, Nicolas A.

    1992-03-01

    This paper describes optical testing procedures used at the National Optical Astronomy Observatories (NOAO) for testing large optics. It begins with a discussion of the philosophy behind the testing approach and then describes a number of different testing methods used at NOAO, including the wire test, full-aperture and sub-aperture Hartmann testing, and scatterplate interferometry. Specific innovations that enhance the testing capabilities are mentioned. NOAO data reduction software is described. Examples are given of specific output formats that are useful to the optician, using illustrations taken from recent testing of a 3.5- meter, f/1.75 borosilicate honeycomb mirror. Finally, we discuss some of the optical testing challenges posed by the large optics for the Gemini 8-meter Telescopes Project.

  18. 49 CFR Appendix E to Part 240 - Recommended Procedures for Conducting Skill Performance Tests

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... tailor their testing procedures to the specific operational realities. This appendix contains FRA's..., headlight? —Couple to cars at a safe speed? —Properly control in train slack and buff forces? —Properly use...

  19. Technical standards and guidelines: molecular genetic testing for ultra-rare disorders.

    PubMed

    Maddalena, Anne; Bale, Sherri; Das, Soma; Grody, Wayne; Richards, Sue

    2005-10-01

    These standards and guidelines are designed primarily as an educational resource for clinical laboratory geneticists to help them provide quality clinical laboratory genetic services. Adherence to these standards and guidelines does not necessarily ensure a successful medical outcome. These standards and guidelines should not be considered inclusive of all proper procedures and tests or exclusive of other procedures and tests that are reasonably directed to obtaining the same results. In determining the propriety of any specific procedure or test, the clinical molecular geneticist should apply his or her own professional judgment to the specific clinical circumstances presented by the individual patient or specimen. It may be prudent, however, to document in the laboratory record the rationale for any significant deviation from these standards and guidelines.

  20. 40 CFR 1065.715 - Natural gas.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PROCEDURES Engine Fluids, Test Fuels, Analytical Gases and Other Calibration Standards § 1065.715 Natural gas... specifications in the following table: Table 1 of § 1065.715—Test Fuel Specifications for Natural Gas Item Value... test fuel not meeting the specifications in paragraph (a) of this section, as follows: (1) You may use...

  1. 40 CFR 1065.715 - Natural gas.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROCEDURES Engine Fluids, Test Fuels, Analytical Gases and Other Calibration Standards § 1065.715 Natural gas... specifications in the following table: Table 1 of § 1065.715—Test Fuel Specifications for Natural Gas Item Value... test fuel not meeting the specifications in paragraph (a) of this section, as follows: (1) You may use...

  2. 40 CFR 1065.715 - Natural gas.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PROCEDURES Engine Fluids, Test Fuels, Analytical Gases and Other Calibration Standards § 1065.715 Natural gas... specifications in the following table: Table 1 of § 1065.715—Test Fuel Specifications for Natural Gas Item Value... test fuel not meeting the specifications in paragraph (a) of this section, as follows: (1) You may use...

  3. 40 CFR 92.113 - Fuel specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) CONTROL OF AIR POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.113 Fuel specifications. (a) Diesel test fuel. (1) The diesel fuels for testing locomotives or locomotive engines designed...) of this section shall be reported in accordance with § 92.133. (b) Natural gas test fuel (compressed...

  4. 40 CFR 92.113 - Fuel specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) CONTROL OF AIR POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.113 Fuel specifications. (a) Diesel test fuel. (1) The diesel fuels for testing locomotives or locomotive engines designed... section shall be reported in accordance with § 92.133. (b) Natural gas test fuel (compressed natural gas...

  5. 40 CFR 92.113 - Fuel specifications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) CONTROL OF AIR POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.113 Fuel specifications. (a) Diesel test fuel. (1) The diesel fuels for testing locomotives or locomotive engines designed... section shall be reported in accordance with § 92.133. (b) Natural gas test fuel (compressed natural gas...

  6. 40 CFR 92.113 - Fuel specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) CONTROL OF AIR POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.113 Fuel specifications. (a) Diesel test fuel. (1) The diesel fuels for testing locomotives or locomotive engines designed... section shall be reported in accordance with § 92.133. (b) Natural gas test fuel (compressed natural gas...

  7. 40 CFR 92.113 - Fuel specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) CONTROL OF AIR POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.113 Fuel specifications. (a) Diesel test fuel. (1) The diesel fuels for testing locomotives or locomotive engines designed...) of this section shall be reported in accordance with § 92.133. (b) Natural gas test fuel (compressed...

  8. 46 CFR 159.007-3 - Production inspections and tests: Independent laboratory's procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Production inspections and tests: Independent laboratory's procedures. 159.007-3 Section 159.007-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND MATERIALS Production Inspection and Tests of...

  9. 46 CFR 159.007-3 - Production inspections and tests: Independent laboratory's procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Production inspections and tests: Independent laboratory's procedures. 159.007-3 Section 159.007-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND MATERIALS Production Inspection and Tests of...

  10. Voyager electronic parts radiation program. Volume 2: Test requirements and procedures

    NASA Technical Reports Server (NTRS)

    Stanley, A. G.; Martin, K. E.; Price, W. E.

    1978-01-01

    Documents are presented outlining the conditions and requirements of the test program. The Appendixes are as follows: appendix A -- Electron Simulation Radiation Test Specification for Voyager Electronic Parts and Devices, appendix B -- Electronic Piece-Part Testing Program for Voyager, appendix C -- Test Procedure for Radiation Screening of Voyager Piece Parts, appendix D -- Boeing In Situ Test Fixture, and appendix E -- Irradiate - Anneal (IRAN) Screening Documents.

  11. 40 CFR 86.1406 - Equipment required and specifications; overview.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... minimize condensation. (b) Fuel and analytical tests. Fuel requirements for the CST are specified in §§ 86...-Cycle Light-Duty Trucks; Certification Short Test Procedures § 86.1406 Equipment required and specifications; overview. (a) Exhaust emission tests. All vehicles subject to this subpart are tested for exhaust...

  12. 40 CFR 86.1406 - Equipment required and specifications; overview.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... minimize condensation. (b) Fuel and analytical tests. Fuel requirements for the CST are specified in §§ 86...-Cycle Light-Duty Trucks; Certification Short Test Procedures § 86.1406 Equipment required and specifications; overview. (a) Exhaust emission tests. All vehicles subject to this subpart are tested for exhaust...

  13. 40 CFR 86.1406 - Equipment required and specifications; overview.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... minimize condensation. (b) Fuel and analytical tests. Fuel requirements for the CST are specified in §§ 86...-Cycle Light-Duty Trucks; Certification Short Test Procedures § 86.1406 Equipment required and specifications; overview. (a) Exhaust emission tests. All vehicles subject to this subpart are tested for exhaust...

  14. 40 CFR 86.1406 - Equipment required and specifications; overview.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... minimize condensation. (b) Fuel and analytical tests. Fuel requirements for the CST are specified in §§ 86...-Cycle Light-Duty Trucks; Certification Short Test Procedures § 86.1406 Equipment required and specifications; overview. (a) Exhaust emission tests. All vehicles subject to this subpart are tested for exhaust...

  15. Development of new test procedures for measuring fine and coarse aggregates specific gravity.

    DOT National Transportation Integrated Search

    2009-09-01

    The objective of the research is to develop and evaluate new test methods at determining the specific gravity and absorption of both fine and coarse aggregates. Current methods at determining the specific gravity and absorption of fine and coarse agg...

  16. 40 CFR 1065.12 - Approval of alternate procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... engine meets all applicable emission standards according to specified procedures. (iii) Use statistical.... (e) We may give you specific directions regarding methods for statistical analysis, or we may approve... statistical tests. Perform the tests as follows: (1) Repeat measurements for all applicable duty cycles at...

  17. Unproven diagnostic procedures in IgE-mediated allergic diseases.

    PubMed

    Niggemann, B; Grüber, C

    2004-08-01

    A considerable body of literature on therapeutic aspects of complementary and alternative medicine has been published in recent years, but little is known on diagnostic procedures. This short review lists complementary and alternative diagnostic procedures for the diagnosis of allergic diseases and presents an assessment of their usefulness for the daily practice. The review of the literature revealed that neither the determination of specific immunoglobulin G-antibodies in serum, the hair-analysis, the cytotoxic test, kinesiology, iridology, or electrodermal testing represent useful tests for the daily practice. To date, no complementary or alternative diagnostic procedure can be recommended as a meaningful element in the diagnostic work-up of allergic diseases. This is especially true for food allergy: properly performed oral food challenges still represent the gold standard for implementing specific diets in food allergic individuals. Ineffective diagnostic approaches may be costly for the consumer and delay appropriate therapy.

  18. A close examination of double filtering with fold change and t test in microarray analysis

    PubMed Central

    2009-01-01

    Background Many researchers use the double filtering procedure with fold change and t test to identify differentially expressed genes, in the hope that the double filtering will provide extra confidence in the results. Due to its simplicity, the double filtering procedure has been popular with applied researchers despite the development of more sophisticated methods. Results This paper, for the first time to our knowledge, provides theoretical insight on the drawback of the double filtering procedure. We show that fold change assumes all genes to have a common variance while t statistic assumes gene-specific variances. The two statistics are based on contradicting assumptions. Under the assumption that gene variances arise from a mixture of a common variance and gene-specific variances, we develop the theoretically most powerful likelihood ratio test statistic. We further demonstrate that the posterior inference based on a Bayesian mixture model and the widely used significance analysis of microarrays (SAM) statistic are better approximations to the likelihood ratio test than the double filtering procedure. Conclusion We demonstrate through hypothesis testing theory, simulation studies and real data examples, that well constructed shrinkage testing methods, which can be united under the mixture gene variance assumption, can considerably outperform the double filtering procedure. PMID:19995439

  19. 46 CFR 164.007-4 - Testing procedure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...: SPECIFICATIONS AND APPROVAL MATERIALS Structural Insulations § 164.007-4 Testing procedure. (a) Tests. All tests.... Measurements of dimensions of fibrous insulations shall be made to the nearest 1.5 mm. (1/16″) on a nominal 30... heat the bottle and sample at 105° ±5 °C. (221° ±9 °F.) for 4 hours, insert the stopper, cool and weigh...

  20. 46 CFR 164.007-4 - Testing procedure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...: SPECIFICATIONS AND APPROVAL MATERIALS Structural Insulations § 164.007-4 Testing procedure. (a) Tests. All tests.... Measurements of dimensions of fibrous insulations shall be made to the nearest 1.5 mm. (1/16″) on a nominal 30... heat the bottle and sample at 105° ±5 °C. (221° ±9 °F.) for 4 hours, insert the stopper, cool and weigh...

  1. 46 CFR 164.007-4 - Testing procedure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...: SPECIFICATIONS AND APPROVAL MATERIALS Structural Insulations § 164.007-4 Testing procedure. (a) Tests. All tests.... Measurements of dimensions of fibrous insulations shall be made to the nearest 1.5 mm. (1/16″) on a nominal 30... heat the bottle and sample at 105° ±5 °C. (221° ±9 °F.) for 4 hours, insert the stopper, cool and weigh...

  2. 46 CFR 164.007-4 - Testing procedure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...: SPECIFICATIONS AND APPROVAL MATERIALS Structural Insulations § 164.007-4 Testing procedure. (a) Tests. All tests.... Measurements of dimensions of fibrous insulations shall be made to the nearest 1.5 mm. (1/16″) on a nominal 30... heat the bottle and sample at 105° ±5 °C. (221° ±9 °F.) for 4 hours, insert the stopper, cool and weigh...

  3. 46 CFR 164.007-4 - Testing procedure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...: SPECIFICATIONS AND APPROVAL MATERIALS Structural Insulations § 164.007-4 Testing procedure. (a) Tests. All tests.... Measurements of dimensions of fibrous insulations shall be made to the nearest 1.5 mm. (1/16″) on a nominal 30... heat the bottle and sample at 105° ±5 °C. (221° ±9 °F.) for 4 hours, insert the stopper, cool and weigh...

  4. 46 CFR 160.062-8 - Procedures for acceptance of testing facility.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Procedures for acceptance of testing facility. 160.062-8 Section 160.062-8 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Releases. Lifesaving Equipment...

  5. 40 CFR 86.1413 - Fuel specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Trucks; Certification Short Test Procedures § 86.1413 Fuel specifications. (a) The test fuel to be used... section. (b) CST test fuels by option. (1) Test Option 1: Use Cold CO fuel as specified in the table in § 86.213-94. (2) Test Option 2: Use Cold CO fuel, as specified in the table in § 86.213-94; optionally...

  6. 40 CFR 86.1413 - Fuel specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Trucks; Certification Short Test Procedures § 86.1413 Fuel specifications. (a) The test fuel to be used... section. (b) CST test fuels by option. (1) Test Option 1: Use Cold CO fuel as specified in the table in § 86.213-94. (2) Test Option 2: Use Cold CO fuel, as specified in the table in § 86.213-94; optionally...

  7. 40 CFR 86.1413 - Fuel specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Trucks; Certification Short Test Procedures § 86.1413 Fuel specifications. (a) The test fuel to be used... section. (b) CST test fuels by option. (1) Test Option 1: Use Cold CO fuel as specified in the table in § 86.213-94. (2) Test Option 2: Use Cold CO fuel, as specified in the table in § 86.213-94; optionally...

  8. 40 CFR 86.1413 - Fuel specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Trucks; Certification Short Test Procedures § 86.1413 Fuel specifications. (a) The test fuel to be used... section. (b) CST test fuels by option. (1) Test Option 1: Use Cold CO fuel as specified in the table in § 86.213-94. (2) Test Option 2: Use Cold CO fuel, as specified in the table in § 86.213-94; optionally...

  9. Project W-314 acceptance test report HNF-4647 for HNF-4646 241-B pit leak detection ANB-WT-LDSTA-231 for project W-314

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    HAMMERS, J.S.

    The purpose of the test was to verify that the AN Tank Farm B Pit Leak Detector components are functionally integrated and operate in accordance with engineering design specifications. The Acceptance Test Procedure HNF-4646,241-AN-B-Pit Leak Detection ANB-WT-LDSTA-231 was conducted between 26 June and 02 July 1999 at the 200E AN Tank Farm. The test has been completed with no open test exceptions. The test was conducted prior to final engineering ''as built'' activities being completed this had no impact on the procedure or test results. All components, identified in the procedure were found to be labeled and identified as writtenmore » in the procedure.« less

  10. 40 CFR 53.51 - Demonstration of compliance with design specifications and manufacturing and test requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... compliance with design specifications and manufacturing and test requirements. (a) Overview. (1) Paragraphs... document its post-manufacturing test procedures. As a minimum, each test shall consist of the following... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Demonstration of compliance with design...

  11. 40 CFR 53.51 - Demonstration of compliance with design specifications and manufacturing and test requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... compliance with design specifications and manufacturing and test requirements. (a) Overview. (1) Paragraphs... document its post-manufacturing test procedures. As a minimum, each test shall consist of the following... 40 Protection of Environment 6 2014-07-01 2014-07-01 false Demonstration of compliance with design...

  12. 40 CFR 53.51 - Demonstration of compliance with design specifications and manufacturing and test requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... compliance with design specifications and manufacturing and test requirements. (a) Overview. (1) Paragraphs... document its post-manufacturing test procedures. As a minimum, each test shall consist of the following... 40 Protection of Environment 6 2013-07-01 2013-07-01 false Demonstration of compliance with design...

  13. 40 CFR 53.51 - Demonstration of compliance with design specifications and manufacturing and test requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... compliance with design specifications and manufacturing and test requirements. (a) Overview. (1) Paragraphs... document its post-manufacturing test procedures. As a minimum, each test shall consist of the following... 40 Protection of Environment 6 2012-07-01 2012-07-01 false Demonstration of compliance with design...

  14. 14 CFR 34.81 - Fuel specifications.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... EXHAUST EMISSION REQUIREMENTS FOR TURBINE ENGINE POWERED AIRPLANES Test Procedures for Engine Smoke Emissions (Aircraft Gas Turbine Engines) § 34.81 Fuel specifications. Fuel having specifications as provided...

  15. Weld procedure produces quality welds for thick sections of Hastelloy-X

    NASA Technical Reports Server (NTRS)

    Flens, F. J.; Fletcher, C. W.; Glasier, L. F., Jr.

    1967-01-01

    Welding program produces premium quality, multipass welds in heavy tube sections of Hastelloy-X. It develops semiautomatic tungsten/inert gas procedures, weld wire procurement specifications material weld properties, welder-operator training, and nondestructive testing inspection techniques and procedures.

  16. 40 CFR 86.1213-08 - Fuel specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Emission Test Procedures for New Gasoline-Fueled, Natural Gas-Fueled, Liquefied Petroleum Gas-Fueled and Methanol-Fueled Heavy-Duty Vehicles § 86.1213-08 Fuel specifications. The test fuels listed in 40 CFR part... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Fuel specifications. 86.1213-08...

  17. 40 CFR 86.1213-08 - Fuel specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Emission Test Procedures for New Gasoline-Fueled, Natural Gas-Fueled, Liquefied Petroleum Gas-Fueled and Methanol-Fueled Heavy-Duty Vehicles § 86.1213-08 Fuel specifications. The test fuels listed in 40 CFR part... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Fuel specifications. 86.1213-08...

  18. 40 CFR 86.1213-08 - Fuel specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Emission Test Procedures for New Gasoline-Fueled, Natural Gas-Fueled, Liquefied Petroleum Gas-Fueled and Methanol-Fueled Heavy-Duty Vehicles § 86.1213-08 Fuel specifications. The test fuels listed in 40 CFR part... 40 Protection of Environment 20 2013-07-01 2013-07-01 false Fuel specifications. 86.1213-08...

  19. 40 CFR 86.1213-08 - Fuel specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Emission Test Procedures for New Gasoline-Fueled, Natural Gas-Fueled, Liquefied Petroleum Gas-Fueled and Methanol-Fueled Heavy-Duty Vehicles § 86.1213-08 Fuel specifications. The test fuels listed in 40 CFR part... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Fuel specifications. 86.1213-08...

  20. 40 CFR 91.417 - Fuel flow measurement specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Fuel flow measurement specifications... Procedures § 91.417 Fuel flow measurement specifications. (a) Fuel flow measurement is required only for raw testing but is allowed for dilute testing. (b) The fuel flow rate measurement instrument must have a...

  1. Validity of diagnoses, procedures, and laboratory data in Japanese administrative data.

    PubMed

    Yamana, Hayato; Moriwaki, Mutsuko; Horiguchi, Hiromasa; Kodan, Mariko; Fushimi, Kiyohide; Yasunaga, Hideo

    2017-10-01

    Validation of recorded data is a prerequisite for studies that utilize administrative databases. The present study evaluated the validity of diagnoses and procedure records in the Japanese Diagnosis Procedure Combination (DPC) data, along with laboratory test results in the newly-introduced Standardized Structured Medical Record Information Exchange (SS-MIX) data. Between November 2015 and February 2016, we conducted chart reviews of 315 patients hospitalized between April 2014 and March 2015 in four middle-sized acute-care hospitals in Shizuoka, Kochi, Fukuoka, and Saga Prefectures and used them as reference standards. The sensitivity and specificity of DPC data in identifying 16 diseases and 10 common procedures were identified. The accuracy of SS-MIX data for 13 laboratory test results was also examined. The specificity of diagnoses in the DPC data exceeded 96%, while the sensitivity was below 50% for seven diseases and variable across diseases. When limited to primary diagnoses, the sensitivity and specificity were 78.9% and 93.2%, respectively. The sensitivity of procedure records exceeded 90% for six procedures, and the specificity exceeded 90% for nine procedures. Agreement between the SS-MIX data and the chart reviews was above 95% for all 13 items. The validity of diagnoses and procedure records in the DPC data and laboratory results in the SS-MIX data was high in general, supporting their use in future studies. Copyright © 2017 The Authors. Production and hosting by Elsevier B.V. All rights reserved.

  2. 40 CFR Appendix B to Part 60 - Performance Specifications

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... manufacturers comply with a comprehensive series of design and performance specifications and test procedures to... must periodically select and test an opacity monitor, that is representative of a group of monitors... program are used. One Run may include results for more than one test condition. Constant emissions means...

  3. 40 CFR Appendix B to Part 60 - Performance Specifications

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... manufacturers comply with a comprehensive series of design and performance specifications and test procedures to... must periodically select and test an opacity monitor, that is representative of a group of monitors... program are used. One Run may include results for more than one test condition. Constant emissions means...

  4. 40 CFR Appendix B to Part 60 - Performance Specifications

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... manufacturers comply with a comprehensive series of design and performance specifications and test procedures to... must periodically select and test an opacity monitor, that is representative of a group of monitors... program are used. One Run may include results for more than one test condition. Constant emissions means...

  5. 40 CFR 86.213 - Fuel specifications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Passenger Vehicles; Cold Temperature Test Procedures § 86.213 Fuel specifications. (a) Gasoline. Use a gasoline test fuel with ethanol (low-level blend only) or without ethanol as follows: (1) You must certify using service accumulation fuel and E10 test fuel as specified in § 86.113 for any vehicles required to...

  6. 40 CFR 86.113-15 - Fuel specifications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Heavy-Duty Vehicles; Test Procedures § 86.113-15 Fuel specifications. Section 86.113-15 includes text... transition to an ethanol-blend test fuel for vehicles certified under subpart S of this part. You may use the test fuels specified in § 86.113-04(a) for vehicles that are not yet subject to testing with the new...

  7. Faying Surface Lubrication Effects on Nut Factors

    NASA Technical Reports Server (NTRS)

    Taylor, Deneen M.; Morrison, Raymond F.

    2006-01-01

    Bolted joint analysis typically is performed using nut factors derived from textbooks and procedures from program requirement documents. Joint specific testing was performed for a critical International Space Station (ISS) joint. Test results indicate that for some configurations the nut factor may be significantly different than accepted textbook values. This paper presents results of joint specific testing to aid in determining if joint specific testing should be performed to insure required preloads are obtained.

  8. 40 CFR 1066.215 - Summary of verification procedures for chassis dynamometers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.215 Summary... judgment. (c) Automated dynamometer verifications and calibrations. In some cases, dynamometers are... specified in this subpart. You may use these automated functions instead of following the procedures we...

  9. 40 CFR 87.81 - Fuel specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) CONTROL OF AIR POLLUTION FROM AIRCRAFT AND AIRCRAFT ENGINES Test Procedures for Engine Smoke Emissions (Aircraft Gas Turbine Engines) § 87.81 Fuel specifications. Fuel having specifications as provided in § 87...

  10. 40 CFR 87.81 - Fuel specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) CONTROL OF AIR POLLUTION FROM AIRCRAFT AND AIRCRAFT ENGINES Test Procedures for Engine Smoke Emissions (Aircraft Gas Turbine Engines) § 87.81 Fuel specifications. Fuel having specifications as provided in § 87...

  11. 77 FR 74559 - Energy Conservation Program for Consumer Products: Test Procedures for Residential Water Heaters...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-17

    ... fossil fuel as applicable to a given water heater. Specifically, the standby loss testing in the existing... important to note that fossil-fueled direct heating equipment and pool heaters typically consume both fossil... procedures for direct heating equipment, fossil-fuel energy consumption is accounted for comprehensively over...

  12. 77 FR 52625 - Petition Requesting Rulemaking To Revise Test Procedures for Glazing Materials in Architectural...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-30

    ... contains notices to the public of #0;the proposed issuance of rules and regulations. The purpose of these... architectural products set forth in our regulations, with those testing procedures contained in ANSI Z97.1, ``American National Standard for Safety Glazing Materials Used in Building--Safety Performance Specifications...

  13. Acceptance test procedure for the L-070 project mechanical equipment and instrumentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loll, C.M.

    1996-04-19

    This document contains the acceptance test procedure for the mechanical equipment and instrumentation installed per the L-070 Project. The specific system to be tested are the pump controls for the 3906 Lift Station and 350-A Lift Station. In addition, verification that signals are being received by the 300 Area Treated Effluent Disposal Facility control system, is also performed.

  14. 9 CFR 147.9 - Standard test procedures for avian influenza.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., Sigma Chemical Co. Cat.# A-6877 or equivalent). (iii) Avian influenza AGID antigen and positive control... test serum well. The control lines will pass through the non-specific line and continue on into the test serum well. The non-specific line does not form a continuous line with positive control lines...

  15. 9 CFR 147.9 - Standard test procedures for avian influenza.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., Sigma Chemical Co. Cat.# A-6877 or equivalent). (iii) Avian influenza AGID antigen and positive control... test serum well. The control lines will pass through the non-specific line and continue on into the test serum well. The non-specific line does not form a continuous line with positive control lines...

  16. 9 CFR 147.9 - Standard test procedures for avian influenza.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., Sigma Chemical Co. Cat.# A-6877 or equivalent). (iii) Avian influenza AGID antigen and positive control... test serum well. The control lines will pass through the non-specific line and continue on into the test serum well. The non-specific line does not form a continuous line with positive control lines...

  17. 9 CFR 147.9 - Standard test procedures for avian influenza.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., Sigma Chemical Co. Cat.# A-6877 or equivalent). (iii) Avian influenza AGID antigen and positive control... test serum well. The control lines will pass through the non-specific line and continue on into the test serum well. The non-specific line does not form a continuous line with positive control lines...

  18. 9 CFR 147.9 - Standard test procedures for avian influenza.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., Sigma Chemical Co. Cat.# A-6877 or equivalent). (iii) Avian influenza AGID antigen and positive control... test serum well. The control lines will pass through the non-specific line and continue on into the test serum well. The non-specific line does not form a continuous line with positive control lines...

  19. 7 CFR 58.930 - Official test methods.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., GENERAL SPECIFICATIONS FOR APPROVED PLANTS AND STANDARDS FOR GRADES OF DAIRY PRODUCTS 1 General Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Operations and Operating Procedures § 58.930 Official test methods. (a) Chemical. Chemical analysis, except where otherwise prescribed...

  20. 7 CFR 58.930 - Official test methods.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., GENERAL SPECIFICATIONS FOR APPROVED PLANTS AND STANDARDS FOR GRADES OF DAIRY PRODUCTS 1 General Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Operations and Operating Procedures § 58.930 Official test methods. (a) Chemical. Chemical analysis, except where otherwise prescribed...

  1. 7 CFR 58.930 - Official test methods.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., GENERAL SPECIFICATIONS FOR APPROVED PLANTS AND STANDARDS FOR GRADES OF DAIRY PRODUCTS 1 General Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Operations and Operating Procedures § 58.930 Official test methods. (a) Chemical. Chemical analysis, except where otherwise prescribed...

  2. 7 CFR 58.930 - Official test methods.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., GENERAL SPECIFICATIONS FOR APPROVED PLANTS AND STANDARDS FOR GRADES OF DAIRY PRODUCTS 1 General Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Operations and Operating Procedures § 58.930 Official test methods. (a) Chemical. Chemical analysis, except where otherwise prescribed...

  3. 7 CFR 58.930 - Official test methods.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., GENERAL SPECIFICATIONS FOR APPROVED PLANTS AND STANDARDS FOR GRADES OF DAIRY PRODUCTS 1 General Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Operations and Operating Procedures § 58.930 Official test methods. (a) Chemical. Chemical analysis, except where otherwise prescribed...

  4. Procedural learning in Parkinson's disease, specific language impairment, dyslexia, schizophrenia, developmental coordination disorder, and autism spectrum disorders: A second-order meta-analysis.

    PubMed

    Clark, Gillian M; Lum, Jarrad A G

    2017-10-01

    The serial reaction time task (SRTT) has been used to study procedural learning in clinical populations. In this report, second-order meta-analysis was used to investigate whether disorder type moderates performance on the SRTT. Using this approach to quantitatively summarise past research, it was tested whether autism spectrum disorder, developmental coordination disorder, dyslexia, Parkinson's disease, schizophrenia, and specific language impairment differentially affect procedural learning on the SRTT. The main analysis revealed disorder type moderated SRTT performance (p=0.010). This report demonstrates comparable levels of procedural learning impairment in developmental coordination disorder, dyslexia, Parkinson's disease, schizophrenia, and specific language impairment. However, in autism, procedural learning is spared. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Prevailing Torque Locking Feature in Threaded Fasteners Using Anaerobic Adhesive

    NASA Technical Reports Server (NTRS)

    Hernandez, Alan; Hess, Daniel P.

    2016-01-01

    This paper presents results from tests to assess the use of anaerobic adhesive for providing a prevailing torque locking feature in threaded fasteners. Test procedures are developed and tests are performed on three fastener materials, four anaerobic adhesives, and both unseated assembly conditions. Five to ten samples are tested for each combination. Tests for initial use, reuse without additional adhesive, and reuse with additional adhesive are performed for all samples. A 48-hour cure time was used for all initial use and reuse tests. Test data are presented as removal torque versus removal angle with the specification required prevailing torque range added for performance assessment. Percent specification pass rates for the all combinations of fastener material, adhesive, and assembly condition are tabulated and reveal use of anaerobic adhesive as a prevailing torque locking feature is viable. Although not every possible fastener material and anaerobic adhesive combination provides prevailing torque values within specification, any combination can be assessed using the test procedures presented. Reuse without additional anaerobic adhesive generally provides some prevailing torque, and in some cases within specification. Reuse with additional adhesive often provides comparable removal torque data as in initial use.

  6. WIPP waste characterization program sampling and analysis guidance manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1991-01-01

    The Waste Isolation Pilot Plant (WIPP) Waste Characterization Program Sampling and Analysis Guidance Manual (Guidance Manual) provides a unified source of information on the sampling and analytical techniques that enable Department of Energy (DOE) facilities to comply with the requirements established in the current revision of the Quality Assurance Program Plan (QAPP) for the WIPP Experimental-Waste Characterization Program (the Program). This Guidance Manual includes all of the sampling and testing methodologies accepted by the WIPP Project Office (DOE/WPO) for use in implementing the Program requirements specified in the QAPP. This includes methods for characterizing representative samples of transuranic (TRU) wastesmore » at DOE generator sites with respect to the gas generation controlling variables defined in the WIPP bin-scale and alcove test plans, as well as waste container headspace gas sampling and analytical procedures to support waste characterization requirements under the WIPP test program and the Resource Conservation and Recovery Act (RCRA). The procedures in this Guidance Manual are comprehensive and detailed and are designed to provide the necessary guidance for the preparation of site specific procedures. The use of these procedures is intended to provide the necessary sensitivity, specificity, precision, and comparability of analyses and test results. The solutions to achieving specific program objectives will depend upon facility constraints, compliance with DOE Orders and DOE facilities' operating contractor requirements, and the knowledge and experience of the TRU waste handlers and analysts. With some analytical methods, such as gas chromatography/mass spectrometry, the Guidance Manual procedures may be used directly. With other methods, such as nondestructive/destructive characterization, the Guidance Manual provides guidance rather than a step-by-step procedure.« less

  7. 24 CFR 200.954 - Supplementary specific requirements under the HUD building product standard and certification...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... shall also include the manufacturer's name, plant location, and shelf life. (c) Periodic tests and quality assurance. Under the procedures set forth in § 200.935(d)(8) concerning periodic tests and quality... administrator. (2) The administrator shall also review the quality assurance procedures twice a year to assure...

  8. 24 CFR 200.954 - Supplementary specific requirements under the HUD building product standard and certification...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... shall also include the manufacturer's name, plant location, and shelf life. (c) Periodic tests and quality assurance. Under the procedures set forth in § 200.935(d)(8) concerning periodic tests and quality... administrator. (2) The administrator shall also review the quality assurance procedures twice a year to assure...

  9. 78 FR 48661 - Notice of Petition for Waiver of Whirlpool Corporation From the Department of Energy Residential...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-09

    ... test procedure specific to a KitchenAid brand dishwasher equipped with a ``water use system.'' DOE... the subject KitchenAid brand dishwasher. DATES: DOE will accept comments, data, and information with.... Whirlpool seeks a waiver from the applicable test procedure for its KitchenAid brand basic model KDTE554C...

  10. Comparison of Anticipation and Study-Test Procedures of Paired-Associate Learning by Children. Final Report.

    ERIC Educational Resources Information Center

    Cole, Lawrence E.

    The study paired-associate (PA) learning via the anticipation (ANT) and study-test (ST) procedures across second, third, fourth and fifth grades. Specifically, age differences in the rate of learning and examining PA learning according to the stage analyses were examined. Retention was also of interest: however, a ceiling effect negated the…

  11. Radiated Susceptibility Test Procedure and Setup Exploiting Crosstalk

    NASA Astrophysics Data System (ADS)

    Grassi, F.; Pignari, S. A.; Spadacini, G.; Bisognin, P.; Pelissou, P.; Marra, S.

    2016-05-01

    In this work, basic principles of an alternative test procedure exploiting crosstalk to reproduce in the terminal loads of a wiring structure the same disturbances that would be induced by traditional radiated susceptibility (RS) tests are presented. Equivalence with radiation is achieved by the use of a generator circuit properly fed with two synchronized RF generators, and holds for whatever loads (even not linear) connected to the terminations of the cable harness. The proposed procedure is here tailored to the specific conditions of incidence foreseen by aerospace Standards on RS. Its effectiveness is validated by measurements carried out in an ad hoc test setup.

  12. The effects of timing of exposure to principles and procedural instruction specificity on learning an electrical troubleshooting skill.

    PubMed

    Eiriksdottir, Elsa; Catrambone, Richard

    2015-12-01

    Domain principles provided in task instructions are assumed to help performance as learners can later apply this knowledge when faced with new tasks. The goal of the research was to investigate whether the timing of the exposure to principles-studying the principles before or while completing training tasks-and the specificity in the accompanying step-by-step procedural instructions would influence learning to troubleshoot a simulated electrical circuit. The results of a pilot study suggested that timing of principle exposure and specificity might interact. This was investigated by comparing the performance of 4 groups of participants (n = 24) who received either general or detailed procedural instructions and were either exposed to the principles before or during the training. The results showed that studying the principles before training benefited test task performance when the procedural instructions were detailed but not when they were general. The results also showed that using general procedural instructions benefited test task performance while using detailed procedural instructions benefited training task performance. Overall the results reveal how the learning situation as a whole must be considered when determining the efficacy of instructional materials, and how conditions can be created where principles enhance learning. (c) 2015 APA, all rights reserved).

  13. Evaluation of the Eberline AMS-3A and AMS-4 Beta continuous air monitors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, M.L.; Sisk, D.R.

    1996-03-01

    Eberline AMS-3A-1 and AMS-4 beta continuous air monitors were tested against the criteria set forth in the ANSI Standards N42.18, Specification and Performance of On-site Instrumentation for Continuously Monitoring Radioactivity in Effluents, and ANSI N42.17B, Performance Specification for Health Physics Instrumentation - Occupational Airborne Radioactivity Monitoring Instrumentation. ANSI N42.18 does not, in general, specify testing procedures for demonstrating compliance with the criteria set forth in the standard; therefore, wherever possible, the testing procedures given in ANSI N42.17B were adopted. In all cases, the more restrictive acceptance criteria and/or the more demanding test conditions of the two standards were used.

  14. Laboratory and clinical genomic data sharing is crucial to improving genetic health care: a position statement of the American College of Medical Genetics and Genomics.

    PubMed

    Acmg Board Of Directors

    2017-07-01

    Disclaimer: These recommendations are designed primarily as an educational resource for medical geneticists and other health-care providers, to help them provide quality medical genetic services. Adherence to these recommendations does not necessarily assure a successful medical outcome. These recommendations should not be considered inclusive of all proper procedures and tests or exclusive of other procedures and tests that are reasonably directed to obtaining the same results. In determining the propriety of any specific procedure or test, the geneticist should apply his or her own professional judgment to the specific clinical circumstances presented by the individual patient or specimen. It may be prudent, however, to document in the patient's record the rationale for any significant deviation from these recommendations.Genet Med advance online publication 05 January 2017.

  15. 40 CFR Appendix B to Part 60 - Performance Specifications

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... series of design and performance specifications and test procedures to certify opacity monitoring... Performance Specification 1? Performance Specification 1 (PS-1) provides (1) requirements for the design... apply to COMS data? The measurement uncertainties associated with COMS data result from several design...

  16. Using the Coefficient of Confidence to Make the Philosophical Switch from a Posteriori to a Priori Inferential Statistics

    ERIC Educational Resources Information Center

    Trafimow, David

    2017-01-01

    There has been much controversy over the null hypothesis significance testing procedure, with much of the criticism centered on the problem of inverse inference. Specifically, p gives the probability of the finding (or one more extreme) given the null hypothesis, whereas the null hypothesis significance testing procedure involves drawing a…

  17. Final Rule for Control of Air Pollution From New Motor Vehicles and New Motor Vehicle Engines: Evaporative and Refueling Emission Regulations for Gasolineand Methanol-Fueled Light-Duty Vehicles and Light-Duty Trucks and Heavy-Duty Vehicles; Technical Amen

    EPA Pesticide Factsheets

    On March 24, 1993 EPA finalized a new test procedure to measure evaporative emissions from motor vehicles. The amendments modify several of the test procedure’s tolerances, equipment specifications, and procedural steps.

  18. Integrated Advanced Microwave Sounding Unit-A (AMSU-A. Engineering Report: Electromagnetic Interface (EMI)/Electromagnetic Radiation (EMR) and Electromagnetic Compatibility (EMC), for the METSAT/METOP AMSU-A1

    NASA Technical Reports Server (NTRS)

    Valdez, A.

    1999-01-01

    This document contains the procedure and the test results of the Advanced Microwave Sounding Unit-A (AMSU-A) Electromagnetic Interference (EMI), Electromagnetic Susceptibility, and Electromagnetic Compatibility (EMC) qualification test for the Meteorological Satellite (METSAT) and the Meteorological Operation Platform (METOP) projects. The test was conducted in accordance with the approved EMI/EMC Test Plan/Procedure, Specification number AE-26151/5D. This document describes the EMI/EMC test performed by Aerojet and it is presented in the following manner: Section-1 contains introductory material and a brief summary of the test results. Section 2 contains more detailed descriptions of the test plan, test procedure, and test results for each type of EMI/EMC test conducted. Section 3 contains supplementary information that includes test data sheets, plots, and calculations collected during the qualification testing.

  19. Test procedures and instructions for single shell tank saltcake cesium removal with crystalline silicotitanate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duncan, J.B.

    1997-01-07

    This document provides specific test procedures and instructions to implement the test plan for the preparation and conduct of a cesium removal test, using Hanford Single Shell Tank Saltcake from tanks 24 t -BY- I 10, 24 1 -U- 108, 24 1 -U- 109, 24 1 -A- I 0 1, and 24 t - S-102, in a bench-scale column. The cesium sorbent to be tested is crystalline siticotitanate. The test plan for which this provides instructions is WHC-SD-RE-TP-024, Hanford Single Shell Tank Saltcake Cesium Removal Test Plan.

  20. Screening for Specific Language Impairment in Preschool Children: Evaluating a Screening Procedure Including the Token Test

    ERIC Educational Resources Information Center

    Willinger, Ulrike; Schmoeger, Michaela; Deckert, Matthias; Eisenwort, Brigitte; Loader, Benjamin; Hofmair, Annemarie; Auff, Eduard

    2017-01-01

    Specific language impairment (SLI) comprises impairments in receptive and/or expressive language. Aim of this study was to evaluate a screening for SLI. 61 children with SLI (SLI-children, age-range 4-6 years) and 61 matched typically developing controls were tested for receptive language ability (Token Test-TT) and for intelligence (Wechsler…

  1. Patients with Parkinson's Disease Learn to Control Complex Systems via Procedural as Well as Non-Procedural Learning

    ERIC Educational Resources Information Center

    Osman, Magda; Wilkinson, Leonora; Beigi, Mazda; Castaneda, Cristina Sanchez; Jahanshahi, Marjan

    2008-01-01

    The striatum is considered to mediate some forms of procedural learning. Complex dynamic control (CDC) tasks involve an individual having to make a series of sequential decisions to achieve a specific outcome (e.g. learning to operate and control a car), and they involve procedural learning. The aim of this study was to test the hypothesis that…

  2. 14 CFR 34.81 - Fuel specifications.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT FUEL VENTING AND EXHAUST EMISSION REQUIREMENTS FOR TURBINE ENGINE POWERED AIRPLANES Test Procedures for Engine Smoke Emissions (Aircraft Gas Turbine Engines) § 34.81 Fuel specifications. Fuel having specifications as provided...

  3. 14 CFR 34.81 - Fuel specifications.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT FUEL VENTING AND EXHAUST EMISSION REQUIREMENTS FOR TURBINE ENGINE POWERED AIRPLANES Test Procedures for Engine Smoke Emissions (Aircraft Gas Turbine Engines) § 34.81 Fuel specifications. Fuel having specifications as provided...

  4. Development of FWD procedures manual.

    DOT National Transportation Integrated Search

    2010-04-01

    In this project, the state-of-practice in FWD testing and analysis procedures were examined : by looking at the standard protocols of a number of other highway agencies. The specific : needs of NJDOT were also examined and a protocol was developed th...

  5. Learning the facts in medical school is not enough: which factors predict successful application of procedural knowledge in a laboratory setting?

    PubMed

    Schmidmaier, Ralf; Eiber, Stephan; Ebersbach, Rene; Schiller, Miriam; Hege, Inga; Holzer, Matthias; Fischer, Martin R

    2013-02-22

    Medical knowledge encompasses both conceptual (facts or "what" information) and procedural knowledge ("how" and "why" information). Conceptual knowledge is known to be an essential prerequisite for clinical problem solving. Primarily, medical students learn from textbooks and often struggle with the process of applying their conceptual knowledge to clinical problems. Recent studies address the question of how to foster the acquisition of procedural knowledge and its application in medical education. However, little is known about the factors which predict performance in procedural knowledge tasks. Which additional factors of the learner predict performance in procedural knowledge? Domain specific conceptual knowledge (facts) in clinical nephrology was provided to 80 medical students (3rd to 5th year) using electronic flashcards in a laboratory setting. Learner characteristics were obtained by questionnaires. Procedural knowledge in clinical nephrology was assessed by key feature problems (KFP) and problem solving tasks (PST) reflecting strategic and conditional knowledge, respectively. Results in procedural knowledge tests (KFP and PST) correlated significantly with each other. In univariate analysis, performance in procedural knowledge (sum of KFP+PST) was significantly correlated with the results in (1) the conceptual knowledge test (CKT), (2) the intended future career as hospital based doctor, (3) the duration of clinical clerkships, and (4) the results in the written German National Medical Examination Part I on preclinical subjects (NME-I). After multiple regression analysis only clinical clerkship experience and NME-I performance remained independent influencing factors. Performance in procedural knowledge tests seems independent from the degree of domain specific conceptual knowledge above a certain level. Procedural knowledge may be fostered by clinical experience. More attention should be paid to the interplay of individual clinical clerkship experiences and structured teaching of procedural knowledge and its assessment in medical education curricula.

  6. EMC Recent Additions

    EPA Pesticide Factsheets

    This page has information about recent changes to promulgated and proposed test methods, perfomance specifications, and quality assurance procedures. It also includes updates and changes to all other approved and proposed test methods.

  7. 40 CFR 86.213-94 - Fuel specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Fuel specifications. 86.213-94 Section...-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.213-94 Fuel specifications. Gasoline... manufacturer and shall be made available to the Administrator upon request. Table—Cold CO Fuel Specifications...

  8. 40 CFR 86.213-94 - Fuel specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Fuel specifications. 86.213-94 Section...-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.213-94 Fuel specifications. Gasoline... manufacturer and shall be made available to the Administrator upon request. Table—Cold CO Fuel Specifications...

  9. 40 CFR 86.213-94 - Fuel specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 19 2013-07-01 2013-07-01 false Fuel specifications. 86.213-94 Section...-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.213-94 Fuel specifications. Gasoline... manufacturer and shall be made available to the Administrator upon request. Table—Cold CO Fuel Specifications...

  10. 40 CFR 80.167 - Confirmatory testing.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) REGULATION OF FUELS AND FUEL ADDITIVES Detergent Gasoline § 80.167 Confirmatory testing. EPA may test a... national, PADD, or fuel-specific options will generally entail a single vehicle test using the procedures detailed in § 80.165. The test fuel(s) used in conducting confirmatory certification testing will contain...

  11. 40 CFR 80.167 - Confirmatory testing.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) REGULATION OF FUELS AND FUEL ADDITIVES Detergent Gasoline § 80.167 Confirmatory testing. EPA may test a... national, PADD, or fuel-specific options will generally entail a single vehicle test using the procedures detailed in § 80.165. The test fuel(s) used in conducting confirmatory certification testing will contain...

  12. 40 CFR 80.167 - Confirmatory testing.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) REGULATION OF FUELS AND FUEL ADDITIVES Detergent Gasoline § 80.167 Confirmatory testing. EPA may test a... national, PADD, or fuel-specific options will generally entail a single vehicle test using the procedures detailed in § 80.165. The test fuel(s) used in conducting confirmatory certification testing will contain...

  13. 40 CFR 80.167 - Confirmatory testing.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) REGULATION OF FUELS AND FUEL ADDITIVES Detergent Gasoline § 80.167 Confirmatory testing. EPA may test a... national, PADD, or fuel-specific options will generally entail a single vehicle test using the procedures detailed in § 80.165. The test fuel(s) used in conducting confirmatory certification testing will contain...

  14. 40 CFR 92.123 - Test procedure; general requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... designed to determine the brake specific emissions of hydrocarbons (HC, total or non-methane as applicable... of calculating brake specific emissions. (v) The engine may be equipped with a production type...

  15. 40 CFR 92.123 - Test procedure; general requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... designed to determine the brake specific emissions of hydrocarbons (HC, total or non-methane as applicable... of calculating brake specific emissions. (v) The engine may be equipped with a production type...

  16. 40 CFR 92.123 - Test procedure; general requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... designed to determine the brake specific emissions of hydrocarbons (HC, total or non-methane as applicable... of calculating brake specific emissions. (v) The engine may be equipped with a production type...

  17. 40 CFR 92.123 - Test procedure; general requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... designed to determine the brake specific emissions of hydrocarbons (HC, total or non-methane as applicable... of calculating brake specific emissions. (v) The engine may be equipped with a production type...

  18. Framework conditions and requirements to ensure the technical functional safety of reprocessed medical devices.

    PubMed

    Kraft, Marc

    2008-09-03

    Testing and restoring technical-functional safety is an essential part of medical device reprocessing. Technical functional tests have to be carried out on the medical device in the course of the validation of reprocessing procedures. These ensure (in addition to the hygiene tests) that the reprocessing procedure is suitable for the medical device. Functional tests are, however, also a part of reprocessing procedures. As a stage in the reprocessing, they ensure for the individual medical device that no damage or other changes limit the performance. When determining which technical-functional tests are to be carried out, the current technological standard has to be taken into account in the form of product-specific and process-oriented norms. Product-specific norms primarily define safety-relevant requirements. The risk management method described in DIN EN ISO 14971 is the basis for recognising hazards; the likelihood of such hazards arising can be minimised through additional technical-functional tests, which may not yet have been standardised. Risk management is part of a quality management system, which must be bindingly certified for manufacturers and processors of critical medical devices with particularly high processing demands by a body accredited by the competent authority.

  19. Framework conditions and requirements to ensure the technical functional safety of reprocessed medical devices

    PubMed Central

    Kraft, Marc

    2008-01-01

    Testing and restoring technical-functional safety is an essential part of medical device reprocessing. Technical functional tests have to be carried out on the medical device in the course of the validation of reprocessing procedures. These ensure (in addition to the hygiene tests) that the reprocessing procedure is suitable for the medical device. Functional tests are, however, also a part of reprocessing procedures. As a stage in the reprocessing, they ensure for the individual medical device that no damage or other changes limit the performance. When determining which technical-functional tests are to be carried out, the current technological standard has to be taken into account in the form of product-specific and process-oriented norms. Product-specific norms primarily define safety-relevant requirements. The risk management method described in DIN EN ISO 14971 is the basis for recognising hazards; the likelihood of such hazards arising can be minimised through additional technical-functional tests, which may not yet have been standardised. Risk management is part of a quality management system, which must be bindingly certified for manufacturers and processors of critical medical devices with particularly high processing demands by a body accredited by the competent authority. PMID:20204095

  20. Immunocytochemical methods to study the distribution of Orientia tsutsugamushi in Leptotrombidium (Acari: Trombiculidae) chiggers.

    PubMed

    Myint, K S; Linthicum, K J; Tanskul, P; Lerdthusnee, K; Vaughn, D W; Manomuth, C; Mongkolsirichaikul, D; Hansukjariya, P; Hastriter, M W

    1998-07-01

    Immunocytochemical methods were developed and tested for their ability to detect the distribution of Orientia tsutsugamushi in paraffin sections of adult chiggers (Leptotrombidium imphalum Vercammen-Grandjean & Langston). Rickettsial antigen was detected by application of a simple direct or amplified immunocytochemistry procedure and an indirect immunofluorescent procedure. In the direct procedure alkaline phosphatase conjugation to the mouse polyclonal antibody to the Karp strain was followed by the HistoMark Red test system to detect rickettsial antigen. The amplification procedure used a similar method but used an unlabeled primary antibody followed by secondary biotinylated antimouse IgG, streptavidin-alkaline phosphatase, and the HistoMark Red test system. The immunofluorescent procedure included a biotinylated secondary antibody followed by addition of a streptavidin-FITC conjugate. Specific tissue tropisms in infected chiggers were observed in the salivary glands, nervous tissue, and ovaries of adult female mites in all procedures; however, nonspecific fluorescence of the chigger limited definitive identification of tissue tropisms with the indirect immunofluorescent procedure.

  1. Species-specific diagnostic assays for Bonamia ostreae and B. exitiosa in European flat oyster Ostrea edulis: conventional, real-time and multiplex PCR.

    PubMed

    Ramilo, Andrea; Navas, J Ignacio; Villalba, Antonio; Abollo, Elvira

    2013-05-27

    Bonamia ostreae and B. exitiosa have caused mass mortalities of various oyster species around the world and co-occur in some European areas. The World Organisation for Animal Health (OIE) has included infections with both species in the list of notifiable diseases. However, official methods for species-specific diagnosis of either parasite have certain limitations. In this study, new species-specific conventional PCR (cPCR) and real-time PCR techniques were developed to diagnose each parasite species. Moreover, a multiplex PCR method was designed to detect both parasites in a single assay. The analytical sensitivity and specificity of each new method were evaluated. These new procedures were compared with 2 OIE-recommended methods, viz. standard histology and PCR-RFLP. The new procedures showed higher sensitivity than the OIE recommended ones for the diagnosis of both species. The sensitivity of tests with the new primers was higher using oyster gills and gonad tissue, rather than gills alone. The lack of a 'gold standard' prevented accurate estimation of sensitivity and specificity of the new methods. The implementation of statistical tools (maximum likelihood method) for the comparison of the diagnostic tests showed the possibility of false positives with the new procedures, although the absence of a gold standard precluded certainty. Nevertheless, all procedures showed negative results when used for the analysis of oysters from a Bonamia-free area.

  2. 40 CFR 91.404 - Test procedure overview.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... to be conducted on an engine dynamometer or equivalent load and speed measurement device. The exhaust... analyzed through the analytical system. (b) The tests are designed to determine the brake-specific...

  3. NASA Glenn's Acoustical Testing Laboratory Awarded Accreditation by the National Voluntary Laboratory Accreditation Program

    NASA Technical Reports Server (NTRS)

    Akers, James C.; Cooper, Beth A.

    2004-01-01

    NASA Glenn Research Center's Acoustical Testing Laboratory (ATL) provides a comprehensive array of acoustical testing services, including sound pressure level, sound intensity level, and sound-power-level testing per International Standards Organization (ISO)1 3744. Since its establishment in September 2000, the ATL has provided acoustic emission testing and noise control services for a variety of customers, particularly microgravity space flight hardware that must meet International Space Station acoustic emission requirements. The ATL consists of a 23- by 27- by 20-ft (height) convertible hemi/anechoic test chamber and a separate sound-attenuating test support enclosure. The ATL employs a personal-computer-based data acquisition system that provides up to 26 channels of simultaneous data acquisition with real-time analysis (ref. 4). Specialized diagnostic tools, including a scanning sound-intensity system, allow the ATL's technical staff to support its clients' aggressive low-noise design efforts to meet the space station's acoustic emission requirement. From its inception, the ATL has pursued the goal of developing a comprehensive ISO 17025-compliant quality program that would incorporate Glenn's existing ISO 9000 quality system policies as well as ATL-specific technical policies and procedures. In March 2003, the ATL quality program was awarded accreditation by the National Voluntary Laboratory Accreditation Program (NVLAP) for sound-power-level testing in accordance with ISO 3744. The NVLAP program is administered by the National Institutes of Standards and Technology (NIST) of the U.S. Department of Commerce and provides third-party accreditation for testing and calibration laboratories. There are currently 24 NVLAP-accredited acoustical testing laboratories in the United States. NVLAP accreditation covering one or more specific testing procedures conducted in accordance with established test standards is awarded upon successful completion of an intensive onsite assessment that includes proficiency testing and documentation review. The ATL NVLAP accreditation currently applies specifically to its ISO 3744 soundpower- level determination procedure (see the photograph) and supporting ISO 17025 quality system, although all ATL operations are conducted in accordance with its quality system. The ATL staff is currently developing additional procedures to adapt this quality system to the testing of space flight hardware in accordance with International Space Station acoustic emission requirements.<

  4. 40 CFR 87.61 - Turbine fuel specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Turbine fuel specifications. 87.61 Section 87.61 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) Definitions. Test Procedures § 87.61 Turbine fuel specifications. Link to an amendment published...

  5. International Seed Testing Association List of stabilized plant names, edition 6

    USDA-ARS?s Scientific Manuscript database

    Seed-testing laboratories determine the quality of seed lots in national and international seed commerce. Those services most commonly requested include purity analysis, noxious-weed seed detection, and viability tests. Rigorous procedures for performing various tests on specific crops have been est...

  6. Expedient Approaches for the Management of Wastes ...

    EPA Pesticide Factsheets

    Report The current study sought to determine waste decontamination conditions that would achieve complete kill for all material types. For these tests, more stringent decontamination procedures were evaluated specifically using pAB amended with a surfactant and/or waste submersion procedures involving agitation.

  7. 40 CFR 1066.275 - Daily dynamometer readiness verification.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.275 Daily... automated process for this verification procedure, perform this evaluation by setting the initial speed and... your dynamometer does not perform this verification with an automated process: (1) With the dynamometer...

  8. Design and development of polyphenylene oxide foam as a reusable internal insulation for LH2 tanks

    NASA Technical Reports Server (NTRS)

    1975-01-01

    Material specification and fabrication process procedures for foam production are presented. The properties of mechanical strength, modulus of elasticity, density and thermal conductivity were measured and related to foam quality. Properties unique to the foam such as a gas layer insulation, density gradient parallel to the fiber direction, and gas flow conductance in both directions were correlated with foam quality. Inspection and quality control tests procedures are outlined and photographs of test equipment and test specimens are shown.

  9. Runway Rubber Removal Specification Development: Field Evaluation Procedures Development.

    DTIC Science & Technology

    1984-07-01

    removal was sufficient enough to restore full pave- ment skid resistance (based on tests with a DBV). With regard to high-pressure water rubber ...over a test surface, the rubber slider resists motion-. The force, parallel to the test surface, which acts on the slider registers an output on a dial...PROCEDURE 1. Check rubber shoe for wear . Replace when the edge is worn by more than 3/16 in as measured with a rule laid flat across the slider width. 2

  10. IMCS reflight certification requirements and design specifications

    NASA Technical Reports Server (NTRS)

    1984-01-01

    The requirements for reflight certification are established. Software requirements encompass the software programs that are resident in the PCC, DEP, PDSS, EC, or any related GSE. A design approach for the reflight software packages is recommended. These designs will be of sufficient detail to permit the implementation of reflight software. The PDSS/IMC Reflight Certification system provides the tools and mechanisms for the user to perform the reflight certification test procedures, test data capture, test data display, and test data analysis. The system as defined will be structured to permit maximum automation of reflight certification procedures and test data analysis.

  11. Sizing Single Cantilever Beam Specimens for Characterizing Facesheet/Core Peel Debonding in Sandwich Structure

    NASA Technical Reports Server (NTRS)

    Ratcliffe, James G.

    2010-01-01

    This paper details part of an effort focused on the development of a standardized facesheet/core peel debonding test procedure. The purpose of the test is to characterize facesheet/core peel in sandwich structure, accomplished through the measurement of the critical strain energy release rate associated with the debonding process. The specific test method selected for the standardized test procedure utilizes a single cantilever beam (SCB) specimen configuration. The objective of the current work is to develop a method for establishing SCB specimen dimensions. This is achieved by imposing specific limitations on specimen dimensions, with the objectives of promoting a linear elastic specimen response, and simplifying the data reduction method required for computing the critical strain energy release rate associated with debonding. The sizing method is also designed to be suitable for incorporation into a standardized test protocol. Preliminary application of the resulting sizing method yields practical specimen dimensions.

  12. Improved techniques for thermomechanical testing in support of deformation modeling

    NASA Technical Reports Server (NTRS)

    Castelli, Michael G.; Ellis, John R.

    1992-01-01

    The feasibility of generating precise thermomechanical deformation data to support constitutive model development was investigated. Here, the requirement is for experimental data that is free from anomalies caused by less than ideal equipment and procedures. A series of exploratory tests conducted on Hastelloy X showed that generally accepted techniques for strain controlled tests were lacking in at least three areas. Specifically, problems were encountered with specimen stability, thermal strain compensation, and temperature/mechanical strain phasing. The source of these difficulties was identified and improved thermomechanical testing techniques to correct them were developed. These goals were achieved by developing improved procedures for measuring and controlling thermal gradients and by designing a specimen specifically for thermomechanical testing. In addition, innovative control strategies were developed to correctly proportion and phase the thermal and mechanical components of strain. Subsequently, the improved techniques were used to generate deformation data for Hastelloy X over the temperature range, 200 to 1000 C.

  13. A SAS(®) macro implementation of a multiple comparison post hoc test for a Kruskal-Wallis analysis.

    PubMed

    Elliott, Alan C; Hynan, Linda S

    2011-04-01

    The Kruskal-Wallis (KW) nonparametric analysis of variance is often used instead of a standard one-way ANOVA when data are from a suspected non-normal population. The KW omnibus procedure tests for some differences between groups, but provides no specific post hoc pair wise comparisons. This paper provides a SAS(®) macro implementation of a multiple comparison test based on significant Kruskal-Wallis results from the SAS NPAR1WAY procedure. The implementation is designed for up to 20 groups at a user-specified alpha significance level. A Monte-Carlo simulation compared this nonparametric procedure to commonly used parametric multiple comparison tests. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  14. 14 CFR 34.60 - Introduction.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... test fuel that meets the specifications described in Appendix 4 of ICAO Annex 16. The test fuel must... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT FUEL VENTING AND EXHAUST EMISSION REQUIREMENTS FOR TURBINE ENGINE POWERED AIRPLANES Test Procedures for Engine Exhaust...

  15. 40 CFR 1065.940 - Emission calculations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... CONTROLS ENGINE-TESTING PROCEDURES Field Testing and Portable Emission Measurement Systems § 1065.940...-specific emissions for each test interval using any applicable information and instructions in the standard.... Determine this fixed value by engineering analysis. [75 FR 68467, Nov. 8, 2010] ...

  16. [The monodigital recognition test (MRT)--a sensitivity-specific variant of Moberg's pick-up test].

    PubMed

    Clemens, R

    1979-01-01

    The Test for Mono-digital Recognition (MRT) is a procedure specifically designed for the measurement of gnostic performance. The new test was derived from MOBERG's Pick-up Test with the aim of eliminating its shortcomings. Additional injuries do not restrict the applicability of the MRT and the test is not confined to the skin area supplied by the median nerve. The MRT expresses the degree of gnostic disturbances by means of a point system. For testing a patient only two to four minutes are needed.

  17. Procedure M - A framework for stratified area estimation. [in multispectral scanner data processing

    NASA Technical Reports Server (NTRS)

    Kauth, R. J.; Cicone, R. C.; Malila, W. A.

    1980-01-01

    This paper describes Procedure M, a systematic approach to processing multispectral scanner data for classification and acreage estimation. A general discussion of the rationale and development of the procedure is given in the context of large-area agricultural applications. Specific examples are given in the form of test results on acreage estimation of spring small grains.

  18. Design certification tests: High Pressure Oxygen Filter (HPOF) program. Summary report

    NASA Technical Reports Server (NTRS)

    Smith, I. D.

    1976-01-01

    Design and acceptance certification test procedures and results are presented for a high pressure oxygen filter developed to protect the sealing surfaces in emergency oxygen systems. Equipment specifications are included.

  19. 40 CFR 610.22 - Device integrity.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary Analysis... to which device manufacture is standardized by means of drawings, specifications, and other... which test data support (b), (c) and (d). ...

  20. 40 CFR 610.22 - Device integrity.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary Analysis... to which device manufacture is standardized by means of drawings, specifications, and other... which test data support (b), (c) and (d). ...

  1. 40 CFR 610.22 - Device integrity.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary Analysis... to which device manufacture is standardized by means of drawings, specifications, and other... which test data support (b), (c) and (d). ...

  2. 40 CFR 610.22 - Device integrity.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary Analysis... to which device manufacture is standardized by means of drawings, specifications, and other... which test data support (b), (c) and (d). ...

  3. Bootstrap-based procedures for inference in nonparametric receiver-operating characteristic curve regression analysis.

    PubMed

    Rodríguez-Álvarez, María Xosé; Roca-Pardiñas, Javier; Cadarso-Suárez, Carmen; Tahoces, Pablo G

    2018-03-01

    Prior to using a diagnostic test in a routine clinical setting, the rigorous evaluation of its diagnostic accuracy is essential. The receiver-operating characteristic curve is the measure of accuracy most widely used for continuous diagnostic tests. However, the possible impact of extra information about the patient (or even the environment) on diagnostic accuracy also needs to be assessed. In this paper, we focus on an estimator for the covariate-specific receiver-operating characteristic curve based on direct regression modelling and nonparametric smoothing techniques. This approach defines the class of generalised additive models for the receiver-operating characteristic curve. The main aim of the paper is to offer new inferential procedures for testing the effect of covariates on the conditional receiver-operating characteristic curve within the above-mentioned class. Specifically, two different bootstrap-based tests are suggested to check (a) the possible effect of continuous covariates on the receiver-operating characteristic curve and (b) the presence of factor-by-curve interaction terms. The validity of the proposed bootstrap-based procedures is supported by simulations. To facilitate the application of these new procedures in practice, an R-package, known as npROCRegression, is provided and briefly described. Finally, data derived from a computer-aided diagnostic system for the automatic detection of tumour masses in breast cancer is analysed.

  4. 40 CFR 89.414 - Air flow measurement specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Air flow measurement specifications. 89.414 Section 89.414 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Emission Test Procedures § 89.414 Air flow measurement specifications. (a) The air flow measurement method...

  5. 40 CFR 89.414 - Air flow measurement specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Air flow measurement specifications. 89.414 Section 89.414 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Emission Test Procedures § 89.414 Air flow measurement specifications. (a) The air flow measurement method...

  6. 40 CFR 89.414 - Air flow measurement specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Air flow measurement specifications. 89.414 Section 89.414 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Emission Test Procedures § 89.414 Air flow measurement specifications. (a) The air flow measurement method...

  7. 40 CFR 89.414 - Air flow measurement specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Air flow measurement specifications. 89.414 Section 89.414 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Emission Test Procedures § 89.414 Air flow measurement specifications. (a) The air flow measurement method...

  8. 40 CFR 89.415 - Fuel flow measurement specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Fuel flow measurement specifications. 89.415 Section 89.415 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Emission Test Procedures § 89.415 Fuel flow measurement specifications. The fuel flow rate measurement...

  9. 40 CFR 90.417 - Fuel flow measurement specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Fuel flow measurement specifications. 90.417 Section 90.417 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Gaseous Exhaust Test Procedures § 90.417 Fuel flow measurement specifications. (a) Fuel flow measurement...

  10. 40 CFR 86.884-6 - Fuel specifications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Fuel specifications. 86.884-6 Section 86.884-6 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... New Diesel Heavy-Duty Engines; Smoke Exhaust Test Procedure § 86.884-6 Fuel specifications. The...

  11. Traveling-Wave Tube Cold-Test Circuit Optimization Using CST MICROWAVE STUDIO

    NASA Technical Reports Server (NTRS)

    Chevalier, Christine T.; Kory, Carol L.; Wilson, Jeffrey D.; Wintucky, Edwin G.; Dayton, James A., Jr.

    2003-01-01

    The internal optimizer of CST MICROWAVE STUDIO (MWS) was used along with an application-specific Visual Basic for Applications (VBA) script to develop a method to optimize traveling-wave tube (TWT) cold-test circuit performance. The optimization procedure allows simultaneous optimization of circuit specifications including on-axis interaction impedance, bandwidth or geometric limitations. The application of Microwave Studio to TWT cold-test circuit optimization is described.

  12. A methodological, task-based approach to Procedure-Specific Simulations training.

    PubMed

    Setty, Yaki; Salzman, Oren

    2016-12-01

    Procedure-Specific Simulations (PSS) are 3D realistic simulations that provide a platform to practice complete surgical procedures in a virtual-reality environment. While PSS have the potential to improve surgeons' proficiency, there are no existing standards or guidelines for PSS development in a structured manner. We employ a unique platform inspired by game design to develop virtual reality simulations in three dimensions of urethrovesical anastomosis during radical prostatectomy. 3D visualization is supported by a stereo vision, providing a fully realistic view of the simulation. The software can be executed for any robotic surgery platform. Specifically, we tested the simulation under windows environment on the RobotiX Mentor. Using urethrovesical anastomosis during radical prostatectomy simulation as a representative example, we present a task-based methodological approach to PSS training. The methodology provides tasks in increasing levels of difficulty from a novice level of basic anatomy identification, to an expert level that permits testing new surgical approaches. The modular methodology presented here can be easily extended to support more complex tasks. We foresee this methodology as a tool used to integrate PSS as a complementary training process for surgical procedures.

  13. Evaluation plan for space station network interface units

    NASA Technical Reports Server (NTRS)

    Weaver, Alfred C.

    1990-01-01

    Outlined here is a procedure for evaluating network interface units (NIUs) produced for the Space Station program. The procedures should be equally applicable to the data management system (DMS) testbed NIUs produced by Honeywell and IBM. The evaluation procedures are divided into four areas. Performance measurement tools are hardware and software that must be developed in order to evaluate NIU performance. Performance tests are a series of tests, each of which documents some specific characteristic of NIU and/or network performance. In general, these performance tests quantify the speed, capacity, latency, and reliability of message transmission under a wide variety of conditions. Functionality tests are a series of tests and code inspections that demonstrate the functionality of the particular subset of ISO protocols which have been implemented in a given NIU. Conformance tests are a series of tests which would expose whether or not selected features within the ISO protocols are present and interoperable.

  14. Refractory Metal Heat Pipe Life Test - Test Plan and Standard Operating Procedures

    NASA Technical Reports Server (NTRS)

    Martin, J. J.; Reid, R. S.

    2010-01-01

    Refractory metal heat pipes developed during this project shall be subjected to various operating conditions to evaluate life-limiting corrosion factors. To accomplish this objective, various parameters shall be investigated, including the effect of temperature and mass fluence on long-term corrosion rate. The test series will begin with a performance test of one module to evaluate its performance and to establish the temperature and power settings for the remaining modules. The performance test will be followed by round-the-clock testing of 16 heat pipes. All heat pipes shall be nondestructively inspected at 6-month intervals. At longer intervals, specific modules will be destructively evaluated. Both the nondestructive and destructive evaluations shall be coordinated with Los Alamos National Laboratory. During the processing, setup, and testing of the heat pipes, standard operating procedures shall be developed. Initial procedures are listed here and, as hardware is developed, will be updated, incorporating findings and lessons learned.

  15. Control of Technology Transfer at JPL

    NASA Technical Reports Server (NTRS)

    Oliver, Ronald

    2006-01-01

    Controlled Technology: 1) Design: preliminary or critical design data, schematics, technical flow charts, SNV code/diagnostics, logic flow diagrams, wirelist, ICDs, detailed specifications or requirements. 2) Development: constraints, computations, configurations, technical analyses, acceptance criteria, anomaly resolution, detailed test plans, detailed technical proposals. 3) Production: process or how-to: assemble, operated, repair, maintain, modify. 4) Manufacturing: technical instructions, specific parts, specific materials, specific qualities, specific processes, specific flow. 5) Operations: how-to operate, contingency or standard operating plans, Ops handbooks. 6) Repair: repair instructions, troubleshooting schemes, detailed schematics. 7) Test: specific procedures, data, analysis, detailed test plan and retest plans, detailed anomaly resolutions, detailed failure causes and corrective actions, troubleshooting, trended test data, flight readiness data. 8) Maintenance: maintenance schedules and plans, methods for regular upkeep, overhaul instructions. 9) Modification: modification instructions, upgrades kit parts, including software

  16. Knowledge dimensions in hypothesis test problems

    NASA Astrophysics Data System (ADS)

    Krishnan, Saras; Idris, Noraini

    2012-05-01

    The reformation in statistics education over the past two decades has predominantly shifted the focus of statistical teaching and learning from procedural understanding to conceptual understanding. The emphasis of procedural understanding is on the formulas and calculation procedures. Meanwhile, conceptual understanding emphasizes students knowing why they are using a particular formula or executing a specific procedure. In addition, the Revised Bloom's Taxonomy offers a twodimensional framework to describe learning objectives comprising of the six revised cognition levels of original Bloom's taxonomy and four knowledge dimensions. Depending on the level of complexities, the four knowledge dimensions essentially distinguish basic understanding from the more connected understanding. This study identifiesthe factual, procedural and conceptual knowledgedimensions in hypothesis test problems. Hypothesis test being an important tool in making inferences about a population from sample informationis taught in many introductory statistics courses. However, researchers find that students in these courses still have difficulty in understanding the underlying concepts of hypothesis test. Past studies also show that even though students can perform the hypothesis testing procedure, they may not understand the rationale of executing these steps or know how to apply them in novel contexts. Besides knowing the procedural steps in conducting a hypothesis test, students must have fundamental statistical knowledge and deep understanding of the underlying inferential concepts such as sampling distribution and central limit theorem. By identifying the knowledge dimensions of hypothesis test problems in this study, suitable instructional and assessment strategies can be developed in future to enhance students' learning of hypothesis test as a valuable inferential tool.

  17. Military Ecological Risk Assessment Framework (MERAF) for Assessment of Risks of Military Training and Testing to Natural Resources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suter II, G.W.

    2003-06-18

    The objective of this research is to provide the DoD with a framework based on a systematic, risk-based approach to assess impacts for management of natural resources in an ecosystem context. This risk assessment framework is consistent with, but extends beyond, the EPA's ecological risk assessment framework, and specifically addresses DoD activities and management needs. MERAF is intended to be consistent with existing procedures for environmental assessment and planning with DoD testing and training. The intention is to supplement these procedures rather than creating new procedural requirements. MERAF is suitable for use for training and testing area assessment and management.more » It does not include human health risks nor does it address specific permitting or compliance requirements, although it may be useful in some of these cases. Use of MERAF fits into the National Environmental Policy Act (NEPA) process by providing a consistent and rigorous way of organizing and conducting the technical analysis for Environmental Impact Statements (EISs) (Sigal 1993; Carpenter 1995; Canter and Sadler 1997). It neither conflicts with, nor replaces, procedural requirements within the NEPA process or document management processes already in place within DoD.« less

  18. Surface cleanliness of fluid systems, specification for

    NASA Technical Reports Server (NTRS)

    1995-01-01

    This specification establishes surface cleanliness levels, test methods, cleaning and packaging requirements, and protection and inspection procedures for determining surface cleanliness. These surfaces pertain to aerospace parts, components, assemblies, subsystems, and systems in contact with any fluid medium.

  19. 40 CFR 89.414 - Air flow measurement specifications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Air flow measurement specifications. 89.414 Section 89.414 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Test Procedures § 89.414 Air flow measurement specifications. (a) The air flow measurement method used...

  20. 40 CFR 87.61 - Turbine fuel specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) CONTROL OF AIR POLLUTION FROM AIRCRAFT AND AIRCRAFT ENGINES Test Procedures for Engine Exhaust Gaseous Emissions (Aircraft and Aircraft Gas Turbine Engines) § 87.61 Turbine fuel specifications. For... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Turbine fuel specifications. 87.61...

  1. 40 CFR 87.61 - Turbine fuel specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) CONTROL OF AIR POLLUTION FROM AIRCRAFT AND AIRCRAFT ENGINES Test Procedures for Engine Exhaust Gaseous Emissions (Aircraft and Aircraft Gas Turbine Engines) § 87.61 Turbine fuel specifications. For... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Turbine fuel specifications. 87.61...

  2. 40 CFR 86.884-6 - Fuel specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Fuel specifications. 86.884-6 Section 86.884-6 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Regulations for New Diesel Heavy-Duty Engines; Smoke Exhaust Test Procedure § 86.884-6 Fuel specifications...

  3. 40 CFR 86.884-6 - Fuel specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Fuel specifications. 86.884-6 Section 86.884-6 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Regulations for New Diesel Heavy-Duty Engines; Smoke Exhaust Test Procedure § 86.884-6 Fuel specifications...

  4. 40 CFR 86.884-6 - Fuel specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Fuel specifications. 86.884-6 Section 86.884-6 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Regulations for New Diesel Heavy-Duty Engines; Smoke Exhaust Test Procedure § 86.884-6 Fuel specifications...

  5. 40 CFR 86.884-6 - Fuel specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 20 2013-07-01 2013-07-01 false Fuel specifications. 86.884-6 Section 86.884-6 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Regulations for New Diesel Heavy-Duty Engines; Smoke Exhaust Test Procedure § 86.884-6 Fuel specifications...

  6. 46 CFR 16.113 - Chemical drug testing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Chemical drug testing. 16.113 Section 16.113 Shipping... General § 16.113 Chemical drug testing. (a) Drug testing programs required by this part must be conducted... should be consulted to determine the specific procedures which must be established and utilized. Drug...

  7. 46 CFR 16.113 - Chemical drug testing.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 1 2014-10-01 2014-10-01 false Chemical drug testing. 16.113 Section 16.113 Shipping... General § 16.113 Chemical drug testing. (a) Drug testing programs required by this part must be conducted... should be consulted to determine the specific procedures which must be established and utilized. Drug...

  8. 46 CFR 16.113 - Chemical drug testing.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false Chemical drug testing. 16.113 Section 16.113 Shipping... General § 16.113 Chemical drug testing. (a) Drug testing programs required by this part must be conducted... should be consulted to determine the specific procedures which must be established and utilized. Drug...

  9. 46 CFR 16.113 - Chemical drug testing.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false Chemical drug testing. 16.113 Section 16.113 Shipping... General § 16.113 Chemical drug testing. (a) Drug testing programs required by this part must be conducted... should be consulted to determine the specific procedures which must be established and utilized. Drug...

  10. 46 CFR 16.113 - Chemical drug testing.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Chemical drug testing. 16.113 Section 16.113 Shipping... General § 16.113 Chemical drug testing. (a) Drug testing programs required by this part must be conducted... should be consulted to determine the specific procedures which must be established and utilized. Drug...

  11. 40 CFR 1065.703 - Distillate diesel fuel.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... CONTROLS ENGINE-TESTING PROCEDURES Engine Fluids, Test Fuels, Analytical Gases and Other Calibration... diesel fuel specified for use as a test fuel. See the standard-setting part to determine which grade to... grades are specified in the following table: Table 1 of § 1065.703—Test Fuel Specifications for...

  12. 40 CFR 86.1111-87 - Test procedures for PCA testing.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... applicable: (i) The manufacturer may use gasoline test fuel meeting the specifications of paragraph (a) of § 86.113 for mileage accumulation. Otherwise, the manufacturer may use fuels other than those specified... the temperature of the test fuel at other than the approximate midvolume of the fuel tank, as...

  13. 40 CFR 86.1111-87 - Test procedures for PCA testing.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... may use gasoline test fuel meeting the specifications of paragraph (a) of § 86.113 for mileage accumulation. Otherwise, the manufacturer may use fuels other than those specified in this section only with advance approval of the Administrator. (ii) The manufacturer may measure the temperature of the test fuel...

  14. 40 CFR 86.1111-87 - Test procedures for PCA testing.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... applicable: (i) The manufacturer may use gasoline test fuel meeting the specifications of paragraph (a) of § 86.113 for mileage accumulation. Otherwise, the manufacturer may use fuels other than those specified... the temperature of the test fuel at other than the approximate midvolume of the fuel tank, as...

  15. 46 CFR 160.171-25 - Production testing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Production testing. 160.171-25 Section 160.171-25...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Immersion Suits § 160.171-25 Production testing. (a) Immersion suit production testing is conducted under the procedures in this section and subpart 159.007 of this...

  16. 46 CFR 160.174-25 - Production testing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Production testing. 160.174-25 Section 160.174-25...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Thermal Protective Aids § 160.174-25 Production testing. (a) Thermal protective aid production testing is conducted under the procedures in this section and subpart...

  17. Summary of EPA Emission Test Methods

    EPA Pesticide Factsheets

    This document provides the publication date and rule status for the air emission test methods, performance specifications and quality assurance procedures. It is updated by the Measurement Technology Group, part of the Air Quality Assessment Div., OAQPS.

  18. Laboratory diagnosis of creatine deficiency syndromes: a technical standard and guideline of the American College of Medical Genetics and Genomics.

    PubMed

    Sharer, J Daniel; Bodamer, Olaf; Longo, Nicola; Tortorelli, Silvia; Wamelink, Mirjam M C; Young, Sarah

    2017-02-01

    Disclaimer: These ACMG Standards and Guidelines are intended as an educational resource for clinical laboratory geneticists to help them provide quality clinical laboratory genetic services. Adherence to these standards and guidelines is voluntary and does not necessarily assure a successful medical outcome. These Standards and Guidelines should not be considered inclusive of all proper procedures and tests or exclusive of others that are reasonably directed to obtaining the same results. In determining the propriety of any specific procedure or test, clinical laboratory geneticists should apply their professional judgment to the specific circumstances presented by the patient or specimen. Clinical laboratory geneticists are encouraged to document in the patient's record the rationale for the use of a particular procedure or test, whether or not it is in conformance with these Standards and Guidelines. They also are advised to take notice of the date any particular guideline was adopted, and to consider other relevant medical and scientific information that becomes available after that date. It also would be prudent to consider whether intellectual property interests may restrict the performance of certain tests and other procedures.Cerebral creatine deficiency syndromes are neurometabolic conditions characterized by intellectual disability, seizures, speech delay, and behavioral abnormalities. Several laboratory methods are available for preliminary and confirmatory diagnosis of these conditions, including measurement of creatine and related metabolites in biofluids using liquid chromatography-tandem mass spectrometry or gas chromatography-mass spectrometry, enzyme activity assays in cultured cells, and DNA sequence analysis. These guidelines are intended to standardize these procedures to help optimize the diagnosis of creatine deficiency syndromes. While biochemical methods are emphasized, considerations for confirmatory molecular testing are also discussed, along with variables that influence test results and interpretation.Genet Med 19 2, 256-263.

  19. A solar energy estimation procedure using remote sensing techniques. [watershed hydrologic models

    NASA Technical Reports Server (NTRS)

    Khorram, S.

    1977-01-01

    The objective of this investigation is to design a remote sensing-aided procedure for daily location-specific estimation of solar radiation components over the watershed(s) of interest. This technique has been tested on the Spanish Creek Watershed, Northern California, with successful results.

  20. 46 CFR 164.015-5 - Procedure for acceptance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...: SPECIFICATIONS AND APPROVAL MATERIALS Plastic Foam, Unicellular, Buoyant, Sheet and Molded Shape § 164.015-5 Procedure for acceptance. (a) Unicellular plastic foam is not subject to formal approval, but will be... manufacturing methods and to select from foam already manufactured sufficient sample material for testing for...

  1. Assessment methods for rehabilitation.

    PubMed

    Biefang, S; Potthoff, P

    1995-09-01

    Diagnostics and evaluation in medical rehabilitation should be based on methods that are as objective as possible. In this context quantitative methods are an important precondition. We conducted for the German Pensions Insurance Institutions (which are in charge of the medical and vocational rehabilitation of workers and employees) a survey on assessment methods for rehabilitation which included an evaluation of American literature, with the aim to indicate procedures that can be considered for adaptation in Germany and to define further research requirements. The survey identified: (1) standardized procedures and instrumented tests for the assessment of musculoskeletal, cardiopulmonary and neurophysiological function; (2) personality, intelligence, achievement, neuropsychological and alcoholism screening tests for the assessment of mental or cognitive function; (3) rating scales and self-administered questionnaires for the assessment of Activities of Daily Living and Instrumental Activities of Daily Living (ADL/IADL Scales); (4) generic profiles and indexes as well as disease-specific measures for the assessment of health-related quality of life and health status; and (5) rating scales for vocational assessment. German equivalents or German versions exist only for a part of the procedures identified. Translation and testing of Anglo-Saxon procedures should have priority over the development of new German methods. The following procedures will be taken into account: (a) instrumented tests for physical function, (b) IADL Scales, (c) generic indexes of health-related quality of life, (d) specific quality of life and health status measures for disorders of the circulatory system, metabolic system, digestive organs, respiratory tract and for cancer, and (e) vocational rating scales.

  2. Energy-efficiency program for clothes washers, clothes dryers, and dishwashers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1977-11-01

    The objectives of this study of dishwashers, clothes washers, and clothes dryers are: to evaluate existing energy efficiency test procedures and recommend the use of specific test procedures for each appliance group and to establish the maximum economically and technologically feasible energy-efficiency improvement goals for each appliance group. Specifically, the program requirements were to determine the energy efficiency of the 1972 models, to evaluate the feasibility improvements that could be implemented by 1980 to maximize energy efficiency, and to calculate the percentage efficiency improvement based on the 1972 baseline and the recommended 1980 targets. The test program was conducted usingmore » 5 dishwashers, 4 top-loading clothes washers, one front-loading clothes washer, 4 electric clothes dryers, and 4 gas clothes dryers. (MCW)« less

  3. Development of a qualification standard for adhesives used in hybrid microcircuits

    NASA Technical Reports Server (NTRS)

    Licari, J. J.; Weigand, B. L.; Soykin, C. A.

    1981-01-01

    Improved qualification standards and test procedures for adhesives used in microelectronic packaging are developed. The test methods in specification for the Selection and Use of Organic Adhesives in Hybrid Microcircuits are reevaluated versus industry and government requirements. Four electrically insulative and four electrically conductive adhesives used in the assembly of hybrid microcircuits are selected to evaluate the proposed revised test methods. An estimate of the cost to perform qualification testing of an adhesive to the requirements of the revised specification is also prepared.

  4. AgRISTARS: Foreign commodity production forecasting. Corn/soybean decision logic development and testing

    NASA Technical Reports Server (NTRS)

    Dailey, C. L.; Abotteen, K. M. (Principal Investigator)

    1980-01-01

    The development and testing of an analysis procedure which was developed to improve the consistency and objectively of crop identification using Landsat data is described. The procedure was developed to identify corn and soybean crops in the U.S. corn belt region. The procedure consists of a series of decision points arranged in a tree-like structure, the branches of which lead an analyst to crop labels. The specific decision logic is designed to maximize the objectively of the identification process and to promote the possibility of future automation. Significant results are summarized.

  5. 40 CFR 1066.101 - Overview.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PROCEDURES Equipment, Fuel, and Gas Specifications § 1066.101 Overview. (a) This subpart addresses equipment related to emission testing, as well as test fuels and analytical gases. This section addresses emission sampling and analytical equipment, test fuels, and analytical gases. (b) The provisions of 40 CFR part 1065...

  6. 40 CFR 1066.101 - Overview.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROCEDURES Equipment, Fuel, and Gas Specifications § 1066.101 Overview. (a) This subpart addresses equipment related to emission testing, as well as test fuels and analytical gases. This section addresses emission sampling and analytical equipment, test fuels, and analytical gases. (b) The provisions of 40 CFR part 1065...

  7. Predictive Accuracy of Exercise Stress Testing the Healthy Adult.

    ERIC Educational Resources Information Center

    Lamont, Linda S.

    1981-01-01

    Exercise stress testing provides information on the aerobic capacity, heart rate, and blood pressure responses to graded exercises of a healthy adult. The reliability of exercise tests as a diagnostic procedure is discussed in relation to sensitivity and specificity and predictive accuracy. (JN)

  8. 40 CFR 90.404 - Test procedure overview.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust Test... operating conditions to be conducted on an engine dynamometer or equivalent load and speed measurement... to determine the brake-specific emissions of non-methane hydrocarbons. The test consists of three...

  9. 40 CFR 86.213-04 - Fuel specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 19 2013-07-01 2013-07-01 false Fuel specifications. 86.213-04 Section...-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.213-04 Fuel specifications. Gasoline... manufacturer and must be made available to the Administrator upon request. The table listing the cold CO fuel...

  10. 40 CFR 86.213-04 - Fuel specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Fuel specifications. 86.213-04 Section...-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.213-04 Fuel specifications. Gasoline... manufacturer and must be made available to the Administrator upon request. The table listing the cold CO fuel...

  11. 40 CFR 89.415 - Fuel flow measurement specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Fuel flow measurement specifications... Emission Test Procedures § 89.415 Fuel flow measurement specifications. The fuel flow rate measurement instrument must have a minimum accuracy of 2 percent of the engine maximum fuel flow rate. The controlling...

  12. 40 CFR 86.213-04 - Fuel specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Fuel specifications. 86.213-04 Section...-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.213-04 Fuel specifications. Gasoline... manufacturer and must be made available to the Administrator upon request. The table listing the cold CO fuel...

  13. Examining the Implicit Relational Assessment Procedure: Four Preliminary Studies

    ERIC Educational Resources Information Center

    Drake, Chad E.; Kellum, Karen Kate; Wilson, Kelly G.; Luoma, Jason B.; Weinstein, Jonathan H.; Adams, Catherine H.

    2010-01-01

    The Implicit Relational Assessment Procedure (IRAP) is a relatively new measure of implicit cognition that tests cognition as relational behavior instead of an associative activity and thus may provide a more specific measure of cognitive repertoires, including those for social biases, than better known implicit measures such as the Implicit…

  14. 24 CFR 200.937 - Supplementary specific procedural requirements under HUD building product standards and...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... requirements under HUD building product standards and certification program for plastic bathtub units, plastic... procedural requirements under HUD building product standards and certification program for plastic bathtub... product certification program. In the case of plastic bathroom fixtures, testing and inspection shall be...

  15. Learning the facts in medical school is not enough: which factors predict successful application of procedural knowledge in a laboratory setting?

    PubMed Central

    2013-01-01

    Background Medical knowledge encompasses both conceptual (facts or “what” information) and procedural knowledge (“how” and “why” information). Conceptual knowledge is known to be an essential prerequisite for clinical problem solving. Primarily, medical students learn from textbooks and often struggle with the process of applying their conceptual knowledge to clinical problems. Recent studies address the question of how to foster the acquisition of procedural knowledge and its application in medical education. However, little is known about the factors which predict performance in procedural knowledge tasks. Which additional factors of the learner predict performance in procedural knowledge? Methods Domain specific conceptual knowledge (facts) in clinical nephrology was provided to 80 medical students (3rd to 5th year) using electronic flashcards in a laboratory setting. Learner characteristics were obtained by questionnaires. Procedural knowledge in clinical nephrology was assessed by key feature problems (KFP) and problem solving tasks (PST) reflecting strategic and conditional knowledge, respectively. Results Results in procedural knowledge tests (KFP and PST) correlated significantly with each other. In univariate analysis, performance in procedural knowledge (sum of KFP+PST) was significantly correlated with the results in (1) the conceptual knowledge test (CKT), (2) the intended future career as hospital based doctor, (3) the duration of clinical clerkships, and (4) the results in the written German National Medical Examination Part I on preclinical subjects (NME-I). After multiple regression analysis only clinical clerkship experience and NME-I performance remained independent influencing factors. Conclusions Performance in procedural knowledge tests seems independent from the degree of domain specific conceptual knowledge above a certain level. Procedural knowledge may be fostered by clinical experience. More attention should be paid to the interplay of individual clinical clerkship experiences and structured teaching of procedural knowledge and its assessment in medical education curricula. PMID:23433202

  16. Procedural justice climate and group power distance: an examination of cross-level interaction effects.

    PubMed

    Yang, Jixia; Mossholder, Kevin W; Peng, T K

    2007-05-01

    In this article, the authors extend research on the cross-level effects of procedural justice climate by theorizing and testing its interaction with group power distance. The results indicated that group power distance moderated the relationships between procedural justice climate and individual-level outcomes (organizational commitment and organization-directed citizenship behavior). More specifically, a larger group power distance was found to attenuate the positive cross-level effects of procedural justice climate. Implications for procedural justice climate research are discussed. 2007 APA, all rights reserved

  17. High Satisfaction and Low Distress in Breast Cancer Patients One Year after BRCA-Mutation Testing without Prior Face-to-Face Genetic Counseling.

    PubMed

    Sie, Aisha S; Spruijt, Liesbeth; van Zelst-Stams, Wendy A G; Mensenkamp, Arjen R; Ligtenberg, Marjolijn J L; Brunner, Han G; Prins, Judith B; Hoogerbrugge, Nicoline

    2016-06-01

    According to standard practice following referral to clinical genetics, most high risk breast cancer (BC) patients in many countries receive face-to-face genetic counseling prior to BRCA-mutation testing (DNA-intake). We evaluated a novel format by prospective study: replacing the intake consultation with telephone, written and digital information sent home. Face-to-face counseling then followed BRCA-mutation testing (DNA-direct). One year after BRCA-result disclosure, 108 participants returned long-term follow-up questionnaires, of whom 59 (55 %) had previously chosen DNA-direct (intervention) versus DNA-intake (standard practice i.e., control: 45 %). Questionnaires assessed satisfaction and psychological distress. All participants were satisfied and 85 % of DNA-direct participants would choose this procedure again; 10 % would prefer DNA-intake and 5 % were undecided. In repeated measurements ANOVA, general distress (GHQ-12, p = 0.01) and BC-specific distress (IES-bc, p = 0.03) were lower in DNA-direct than DNA-intake at all time measurements. Heredity-specific distress (IES-her) did not differ significantly between groups. Multivariate regression analyses showed that choice of procedure did not significantly contribute to either general or heredity-specific distress. BC-specific distress (after BC diagnosis) did contribute to both general and heredity-specific distress. This suggests that higher distress scores reflected BC experience, rather than the type of genetic diagnostic procedure. In conclusion, the large majority of BC patients that used DNA-direct reported high satisfaction without increased distress both in the short term, and 1 year after conclusion of genetic testing.

  18. 40 CFR 1065.705 - Residual and intermediate residual fuel.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... fuel. 1065.705 Section 1065.705 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Engine Fluids, Test Fuels, Analytical Gases and Other... categories in the following table: Table 1 of § 1065.705—Service Accumulation and Test Fuel Specifications...

  19. 40 CFR 1065.705 - Residual and intermediate residual fuel.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... fuel. 1065.705 Section 1065.705 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Engine Fluids, Test Fuels, Analytical Gases and Other... in the following table: Table 1 of § 1065.705—Service Accumulation and Test Fuel Specifications for...

  20. 40 CFR 1065.705 - Residual and intermediate residual fuel.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... fuel. 1065.705 Section 1065.705 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Engine Fluids, Test Fuels, Analytical Gases and Other... categories in the following table: Table 1 of § 1065.705—Service Accumulation and Test Fuel Specifications...

  1. Ride Dynamics and Evaluation of Human Exposure to Whole Body Vibration. Change 1

    DTIC Science & Technology

    2012-04-03

    vehicle specification and/or the detailed test plan. This (half-round obstacle) accelerometer will be low-pass filtered ( post test ) at 30 Hz...Engineers TARADCOM Tank-Automotive Research and Development Command TOP Test Operations Procedure VDV Vibration Dose Value WBV Whole Body...

  2. 40 CFR 1042.840 - Application requirements for remanufactured engines.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... scheduled maintenance you did. (g) List the specifications of the test fuel to show that it falls within the... as described in the application (including the test procedures, test parameters, and test fuels) to... other basic parameters of the engine's design and emission controls. List the fuel type on which your...

  3. 40 CFR 59.623 - What must I include in my application?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) List the specifications of the test fuel to show that it falls within the required ranges specified in... application (including the test procedures, test parameters, and test fuels) to show you meet the requirements... PRODUCTS Control of Evaporative Emissions From New and In-Use Portable Fuel Containers Certifying Emission...

  4. 40 CFR 59.623 - What must I include in my application?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) List the specifications of the test fuel to show that it falls within the required ranges specified in... application (including the test procedures, test parameters, and test fuels) to show you meet the requirements... PRODUCTS Control of Evaporative Emissions From New and In-Use Portable Fuel Containers Certifying Emission...

  5. 40 CFR 59.623 - What must I include in my application?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) List the specifications of the test fuel to show that it falls within the required ranges specified in... application (including the test procedures, test parameters, and test fuels) to show you meet the requirements... PRODUCTS Control of Evaporative Emissions From New and In-Use Portable Fuel Containers Certifying Emission...

  6. 40 CFR 1042.840 - Application requirements for remanufactured engines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... scheduled maintenance you did. (g) List the specifications of the test fuel to show that it falls within the... as described in the application (including the test procedures, test parameters, and test fuels) to... other basic parameters of the engine's design and emission controls. List the fuel type on which your...

  7. 40 CFR 59.623 - What must I include in my application?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) List the specifications of the test fuel to show that it falls within the required ranges specified in... application (including the test procedures, test parameters, and test fuels) to show you meet the requirements... PRODUCTS Control of Evaporative Emissions From New and In-Use Portable Fuel Containers Certifying Emission...

  8. 40 CFR 1042.840 - Application requirements for remanufactured engines.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... scheduled maintenance you did. (g) List the specifications of the test fuel to show that it falls within the... as described in the application (including the test procedures, test parameters, and test fuels) to... other basic parameters of the engine's design and emission controls. List the fuel type on which your...

  9. 40 CFR 59.623 - What must I include in my application?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) List the specifications of the test fuel to show that it falls within the required ranges specified in... application (including the test procedures, test parameters, and test fuels) to show you meet the requirements... PRODUCTS Control of Evaporative Emissions From New and In-Use Portable Fuel Containers Certifying Emission...

  10. Detailed Concepts in Performing Oversight on an Army Radiographic Inspection Site

    DTIC Science & Technology

    2017-03-01

    number of facilities that perform various nondestructive tests , inspections, and evaluations. The U.S. Army Armament Research, Development and...procedures, and documentation in place to conform to nationally recognized standards. This report specifically reviews the radiographic testing ...X-ray Nondestructive testing (NDT) Radiographic testing (RT) Computed tomography (CT) 16. SECURITY

  11. Arc tracking of cables for space applications

    NASA Technical Reports Server (NTRS)

    Koenig, D.; Frontzek, F. R.; Hanson, J.; Reher, H. J.; Judd, M. D.; Bryant, D.

    1995-01-01

    The main objective of this study is to develop a new test method that is suitable for the assessment of the resistance of aerospace cables to arc tracking for different specific environmental and network conditions of spacecrafts. This paper reports the purpose, test conditions, test specimen, test procedure, and test acceptance criteria of seven different (200-250 mm long) cables.

  12. [Modern Diagnosis and Therapy of the rhinitis allergica].

    PubMed

    Hauswald, B; Yarin, Y M

    2015-05-01

    The prevalence of allergic diseases is increasing worldwide. The highest increase rate is observed in rhinitis allergica. Apart from the anamnesis, the diagnosis relies mainly on skin tests, laboratory analyses and if necessary provocation tests. Symptomatic and causal therapy with abstention and specific immunotherapy are available as therapeutic means. Specific immunotherapy should be aspired as the method of choice. It is comprised of subcutane and sublingular immunity therapy. Usually native allergens and allergoids are used as therapeutics. Recombinant allergens are currently under development. Modern therapy procedures involving these drugs consist of year-round or pre- and co-seasonal treatment which spans at least 3-4 years. In cases of polyvalent allergy, different types of drugs and therapy procedures can be combined. The future of rhinitis allergica treatment lies in further development of specific immunotherapy. © Georg Thieme Verlag KG Stuttgart · New York.

  13. 46 CFR 162.050-1 - Scope.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Pollution Prevention Equipment § 162.050-1 Scope. (a) This subpart contains... specifications for this equipment; (3) Tests required for approval; (4) Procedures for obtaining designation as a...

  14. Gas tungsten arc welding of aluminum alloys 6XXX. Welding procedure specification. Supplement 1. Records of procedure qualification tests. [6061 and 6063

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wodtke, C.H.; Frizzell, D.R.; Plunkett, W.A.

    1986-06-01

    Procedure WPS-1003 is qualified under Section IX of the ASME Boiler and Pressure Vessel Code for gas tungsten arc welding of aluminum alloys 6061 and 6063 (P-23), in thickness range 0.035 to 0.516 inch; filler metal is ER4043 (F-23) or ER5356 (F-22); shielding gas is argon.

  15. 49 CFR 179.7 - Quality assurance program.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... means to detect any nonconformity in the manufacturing, repair, inspection, testing, and qualification... quality control personnel. (3) Procedures to ensure that the latest applicable drawings, design calculations, specifications, and instructions are used in manufacture, inspection, testing, and repair. (4...

  16. 76 FR 55842 - Partial Approval and Partial Disapproval of Air Quality Implementation Plans; California; San...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-09

    ... sometimes approves a rule only as a SIP strengthening action (e.g., to update definitions, add test methods... standards (e.g., materials specifications, test methods, sampling procedures, and business practices) that...

  17. Assessment of simple colorimetric procedures to determine smoking status of diabetic subjects.

    PubMed

    Smith, R F; Mather, H M; Ellard, G A

    1998-02-01

    The performance of a simple colorimetric assay for urinary nicotine metabolites to assess smoking status in diabetic subjects (n = 251) was investigated. Several variations of the colorimetric assay and a qualitative extraction procedure were evaluated in comparison with a cotinine immunoassay as the "gold standard." Among these, the best overall performance was achieved with the qualitative test (sensitivity 95%; specificity 100%). The quantitative measurement of total nicotine metabolites performed less well (sensitivity 92%; specificity 97%) but could be improved by incorporating a blank extraction (sensitivity 98%; specificity 98%). Allowance for diuresis appeared to offer no advantage over the other methods. These results support previous findings regarding the use of these colorimetric procedures in nondiabetic subjects and, contrary to other recent observations, their performance was not impaired in diabetic patients.

  18. Analytic Validation of Immunohistochemistry Assays: New Benchmark Data From a Survey of 1085 Laboratories.

    PubMed

    Stuart, Lauren N; Volmar, Keith E; Nowak, Jan A; Fatheree, Lisa A; Souers, Rhona J; Fitzgibbons, Patrick L; Goldsmith, Jeffrey D; Astles, J Rex; Nakhleh, Raouf E

    2017-09-01

    - A cooperative agreement between the College of American Pathologists (CAP) and the United States Centers for Disease Control and Prevention was undertaken to measure laboratories' awareness and implementation of an evidence-based laboratory practice guideline (LPG) on immunohistochemical (IHC) validation practices published in 2014. - To establish new benchmark data on IHC laboratory practices. - A 2015 survey on IHC assay validation practices was sent to laboratories subscribed to specific CAP proficiency testing programs and to additional nonsubscribing laboratories that perform IHC testing. Specific questions were designed to capture laboratory practices not addressed in a 2010 survey. - The analysis was based on responses from 1085 laboratories that perform IHC staining. Ninety-six percent (809 of 844) always documented validation of IHC assays. Sixty percent (648 of 1078) had separate procedures for predictive and nonpredictive markers, 42.7% (220 of 515) had procedures for laboratory-developed tests, 50% (349 of 697) had procedures for testing cytologic specimens, and 46.2% (363 of 785) had procedures for testing decalcified specimens. Minimum case numbers were specified by 85.9% (720 of 838) of laboratories for nonpredictive markers and 76% (584 of 768) for predictive markers. Median concordance requirements were 95% for both types. For initial validation, 75.4% (538 of 714) of laboratories adopted the 20-case minimum for nonpredictive markers and 45.9% (266 of 579) adopted the 40-case minimum for predictive markers as outlined in the 2014 LPG. The most common method for validation was correlation with morphology and expected results. Laboratories also reported which assay changes necessitated revalidation and their minimum case requirements. - Benchmark data on current IHC validation practices and procedures may help laboratories understand the issues and influence further refinement of LPG recommendations.

  19. 40 CFR 610.34 - Special test conditions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the device was installed. (b) High altitude. Devices for which specific claims of improved fuel economy at high altitude are made may be tested using the procedures in subpart D, at altitudes above 4000 feet. For other devices, testing at high altitude may be necessary for determining whether a device...

  20. 10 CFR 431.401 - Petitions for waiver, and applications for interim waiver, of test procedure.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... more design characteristics which prevent testing of the basic model according to the prescribed test... its true energy consumption characteristics as to provide materially inaccurate comparative data. (2... design characteristic(s) constituting the grounds for the petition, and the specific requirements sought...

  1. 10 CFR 431.401 - Petitions for waiver, and applications for interim waiver, of test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... more design characteristics which prevent testing of the basic model according to the prescribed test... its true energy consumption characteristics as to provide materially inaccurate comparative data. (2... design characteristic(s) constituting the grounds for the petition, and the specific requirements sought...

  2. 10 CFR 431.401 - Petitions for waiver, and applications for interim waiver, of test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... more design characteristics which prevent testing of the basic model according to the prescribed test... its true energy consumption characteristics as to provide materially inaccurate comparative data. (2... design characteristic(s) constituting the grounds for the petition, and the specific requirements sought...

  3. 40 CFR Figure E-1 to Subpart E of... - Designation Testing Checklist

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Field Sampling Procedure (§ 53.30, .31, .34) Design Specification Tests Filter (L-6) Range of... Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II... Process or of Documented Evidence: Performance, Design or Application Spec. Corresponding to Sections of...

  4. 40 CFR Figure E-1 to Subpart E of... - Designation Testing Checklist

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Field Sampling Procedure (§ 53.30, .31, .34) Design Specification Tests Filter (L-6) Range of... Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II... Process or of Documented Evidence: Performance, Design or Application Spec. Corresponding to Sections of...

  5. 40 CFR Figure E-1 to Subpart E of... - Designation Testing Checklist

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Field Sampling Procedure (§ 53.30, .31, .34) Design Specification Tests Filter ( L-6) Range of... Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II... Process or of Documented Evidence: Performance, Design or Application Spec. Corresponding to Sections of...

  6. Regents Examinations and Competency Tests. School Administrator's Manual, June 1985 Edition.

    ERIC Educational Resources Information Center

    1985

    Intended for use by school administrators, guidance counselors, teachers and proctors, this manual contains general information on the New York State Regents examinations and competency tests, as well as specific regulations and procedures for ordering, administering, and rating these examinations. The competency testing requirements for a local…

  7. Technical specification for vacuum systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khaw, J.

    The vacuum systems at the Stanford Linear Accelerator Center (SLAC) are primarily of all-metal construction and operate at pressures from 10/sup -5/ to 10/sup -11/ Torr. The primary gas loads during operation result from thermal desorption and beam-induced desorption from the vacuum chamber walls. These desorption rates can be extremely high in the case of hydrocarbons and other contaminants. These specifications place a major emphasis on eliminating contamination sources. The specifications and procedures have been written to insure the cleanliness and vacuum integrity of all SLAC vacuum systems, and to assist personnel involved with SLAC vacuum systems in choosing andmore » designing components that are compatible with existing systems and meet the quality and reliability of SLAC vacuum standards. The specification includes requirements on design, procurement, fabrication, chemical cleaning, clean room practices, welding and brazing, helium leak testing, residual gas analyzer testing, bakeout, venting, and pumpdown. Also appended are specifications regarding acceptable vendors, isopropyl alcohol, bakeable valve cleaning procedure, mechanical engineering safety inspection, notes on synchrotron radiation, and specifications of numerous individual components. (LEW)« less

  8. What Happened to the Streptococci: Overview of Taxonomic and Nomenclature Changes

    PubMed Central

    Facklam, Richard

    2002-01-01

    Since the division of the Streptococcus genus into enterococci, lactococci, and streptococci in 1984, many changes in the nomenclature and taxonomy of the Streptococcus genus have taken place. The application of genetic comparisons has improved the proper classification of the different species. The Lancefield system of serogrouping the streptococci by the expression of beta-hemolysis on blood agar plates is still very useful for the identification of streptococci for patient management. The Lancefield grouping system cannot be used in itself for accurate identification of specific beta-hemolytic species, but it can be a useful part of the identification procedure. Except for identification of the “Streptococcus bovis group” of species and Streptococcus suis, Lancefield grouping is of little value in identification of the non-beta-hemolytic streptococci and related genera. In fact, identification of the non-beta-hemolytic species is problematic for conventional as well as commercially available identification procedures. A combination of conventional tests and specific chromogenic tests suggested by several investigators is presented and discussed. Tables are included that suggest tests and procedures to guide investigators attempting to identify all the species. PMID:12364372

  9. Preliminary vibration, acoustic, and shock design and test criteria for components on the Lightweight External Tank (LWT)

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The Space Shuttle LWT is divided into zones and subzones. Zones are designated primarily to assist in determining the applicable specifications. A subzone (general Specification) is available for use when the location of the component is known but component design and weight are not well defined. When the location, weight, and mounting configuration of the component are known, specifications for appropriate subzone weight ranges are available. Along with the specifications are vibration, acoustic, shock, transportation, handling, and acceptance test requirements and procedures. A method of selecting applicable vibration, acoustic, and shock specifications is presented.

  10. Chemical, Biological, and Radiological Contamination Survivability: Material Effects Testing

    DTIC Science & Technology

    2012-06-22

    form that can be compared to pretest and posttest functional performance data. If Soldiers are desired, ensure a Test Schedule and Review Committee...test execution. f. The material’s performance specification should also be reviewed before planning test execution. For example , the...test data, and conformance with specified test and operating procedures cannot be overemphasized. 3.1 Test Planning. 3.1.1 Pretest Preparation

  11. Bubble formation in microgravity

    NASA Technical Reports Server (NTRS)

    Antar, Basil N.

    1994-01-01

    Two KC-135 flight campaigns have been conducted to date which are specifically dedicated to study bubble formation in microgravity. The first flight was conducted during March 14-18, 1994, and the other during June 20-24, 1994. The results from the June 1994 flight have not been analyzed yet, while the results from the March flight have been partially analyzed. In the first flight three different experiments were performed, one with the specific aim at determining whether or not cavitation can take place during any of the fluid handling procedures adopted in the shuttle bioprocessing experiments. The other experiments were concerned with duplicating some of the procedures that resulted in bubble formation, namely the NCS filling procedure and the needle scratch of a solid surface. The results from this set of experiments suggest that cavitation did not take place during any of the fluid handling procedures. The results clearly indicate that almost all were generated as a result of the breakup of the gas/liquid interface. This was convincingly demonstrated in the scratch tests as well as in the liquid fill tests.

  12. Validation of biological activity testing procedure of recombinant human interleukin-7.

    PubMed

    Lutsenko, T N; Kovalenko, M V; Galkin, O Yu

    2017-01-01

    Validation procedure for method of monitoring the biological activity of reсombinant human interleukin-7 has been developed and conducted according to the requirements of national and international recommendations. This method is based on the ability of recombinant human interleukin-7 to induce proliferation of T lymphocytes. It has been shown that to control the biological activity of recombinant human interleukin-7 peripheral blood mononuclear cells (PBMCs) derived from blood or cell lines can be used. Validation charac­teristics that should be determined depend on the method, type of product or object test/measurement and biological test systems used in research. The validation procedure for the method of control of biological activity of recombinant human interleukin-7 in peripheral blood mononuclear cells showed satisfactory results on all parameters tested such as specificity, accuracy, precision and linearity.

  13. 40 CFR 87.81 - Fuel specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Fuel specifications. 87.81 Section 87.81 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) Definitions. Test Procedures for Engine Smoke Emissions (Aircraft Gas Turbine Engines) § 87.81 Fuel...

  14. 40 CFR 1065.205 - Performance specifications for measurement instruments.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Performance specifications for measurement instruments. 1065.205 Section 1065.205 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments § 1065.205 Performance...

  15. 40 CFR 1065.205 - Performance specifications for measurement instruments.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Performance specifications for measurement instruments. 1065.205 Section 1065.205 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments § 1065.205 Performance...

  16. 40 CFR 1065.205 - Performance specifications for measurement instruments.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Performance specifications for measurement instruments. 1065.205 Section 1065.205 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments § 1065.205 Performance...

  17. 40 CFR 1065.205 - Performance specifications for measurement instruments.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Performance specifications for measurement instruments. 1065.205 Section 1065.205 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments § 1065.205 Performance...

  18. An audit of imaging test utilization for the management of lymphoma in an oncology hospital: implications for resource planning?

    PubMed

    Schwartz, A; Gospodarowicz, M K; Khalili, K; Pintilie, M; Goddard, S; Keller, A; Tsang, R W

    2006-02-01

    The purpose of this study was to assist with resource planning by examining the pattern of physician utilization of imaging procedures for lymphoma patients in a dedicated oncology hospital. The proportion of imaging tests ordered for routine follow up with no specific clinical indication was quantified, with specific attention to CT scans. A 3-month audit was performed. The reasons for ordering all imaging procedures (X-rays, CT scans, ultrasound, nuclear scan and MRI) were determined through a retrospective chart review. 411 lymphoma patients had 686 assessments (sets of imaging tests) and 981 procedures (individual imaging tests). Most procedures were CT scans (52%) and chest radiographs (30%). The most common reasons for ordering imaging were assessing response (23%), and investigating new symptoms (19%). Routine follow up constituted 21% of the assessments (142/686), and of these, 82% were chest radiographs (116/142), while 24% (34/142) were CT scans. With analysis restricted to CT scans (296 assessments in 248 patients), the most common reason for ordering CT scans were response evaluation (40%), and suspicion of recurrence and/or new symptom (23%). Follow-up CT scans done with no clinical indication comprised 8% (25/296) of all CT assessments. Staging CT scans were under-represented at 6% of all assessments. Imaging with CT scans for follow up of asymptomatic patients is infrequent. However, scans done for staging new lymphoma patients were unexpectedly low in frequency, due to scans done elsewhere prior to referral. This analysis uncovered utilization patterns, helped resource planning and provided data to reduce unnecessary imaging procedures.

  19. ATLS-stowage and deployment testing of medical supplies and pharmaceuticals

    NASA Technical Reports Server (NTRS)

    Gosbee, John; Benz, Darren; Lloyd, Charles W.; Bueker, Richard; Orsak, Debra

    1991-01-01

    The objective is to evaluate stowage and deployment methods for the Health Maintenance Facility (HMF) during microgravity. The specific objectives of this experiment are: (1) to evaluate the stowage and deployment mechanisms for the medical supplies; and (2) to evaluate the procedures for performing medical scenarios. To accomplish these objectives, the HMF test mini-racks will contain medical equipment mounted in the racks; and self-contained drawers with various mechanisms for stowing and deploying items. The medical supplies and pharmaceuticals will be destowed, handled, and restowed. The in-flight test procedures and other aspects of the KC-135 parabolic flight test to simulate weightlessness are presented.

  20. Behavioral phenotyping of mice in pharmacological and toxicological research.

    PubMed

    Karl, Tim; Pabst, Reinhard; von Hörsten, Stephan

    2003-07-01

    The evaluation of behavioral effects is an important component for the in vivo screening of drugs or potentially toxic compounds in mice. Ideally, such screening should be composed of monitoring general health, sensory functions, and motor abilities, right before specific behavioral domains are tested. A rational strategy in the design and procedure of testing as well as an effective composition of different well-established and reproducible behavioral tests can minimize the risk of false positive and false negative results in drug screening. In the present review we describe such basic considerations in planning experiments, selecting strains of mice, and propose groups of behavioral tasks suitable for a reliable detection of differences in specific behavioral domains in mice. Screening of general health and neurophysiologic functions (reflexes, sensory abilities) and motor function (pole test, wire hang test, beam walking, rotarod, accelerod, and footprint) as well as specific hypothesis-guided testing in the behavioral domains of learning and memory (water maze, radial maze, conditioned fear, and avoidance tasks), emotionality (open field, hole board, elevated plus maze, and object exploration), nociception (tail flick, hot plate), psychiatric-like conditions (porsolt swim test, acoustic startle response, and prepulse inhibition), and aggression (isolation-induced aggression, spontaneous aggression, and territorial aggression) are described in further detail. This review is designed to describe a general approach, which increases reliability of behavioral screening. Furthermore, it provides an overview on a selection of specific procedures suitable for but not limited to behavioral screening in pharmacology and toxicology.

  1. Northwest Manufacturing Initiative

    DTIC Science & Technology

    2013-03-26

    Testing of Metallic Materials] specifications. For high temperature tests, a heated water bath was use while for low temperature testing down to...Weld metal and heat affected zones were evaluated using Charpy and E399 fracture toughness methods. The influence of temperature , loading rate, CVN...determine the influence of fracture test methods and welding procedures on toughness. Room temperature E399 tests, (CTS) were carried out under

  2. Fabrication of fuel pin assemblies, phase 3

    NASA Technical Reports Server (NTRS)

    Keeton, A. R.; Stemann, L. G.

    1972-01-01

    Five full size and eight reduced length fuel pins were fabricated for irradiation testing to evaluate design concepts for a fast spectrum lithium cooled compact space power reactor. These assemblies consisted of uranium mononitride fuel pellets encased in a T-111 (Ta-8W-2Hf) clad with a tungsten barrier separating fuel and clad. Fabrication procedures were fully qualified by process development and assembly qualification tests. Detailed specifications and procedures were written for the fabrication and assembly of prototype fuel pins.

  3. Development and validation of trauma surgical skills metrics: Preliminary assessment of performance after training.

    PubMed

    Shackelford, Stacy; Garofalo, Evan; Shalin, Valerie; Pugh, Kristy; Chen, Hegang; Pasley, Jason; Sarani, Babak; Henry, Sharon; Bowyer, Mark; Mackenzie, Colin F

    2015-07-01

    Maintaining trauma-specific surgical skills is an ongoing challenge for surgical training programs. An objective assessment of surgical skills is needed. We hypothesized that a validated surgical performance assessment tool could detect differences following a training intervention. We developed surgical performance assessment metrics based on discussion with expert trauma surgeons, video review of 10 experts and 10 novice surgeons performing three vascular exposure procedures and lower extremity fasciotomy on cadavers, and validated the metrics with interrater reliability testing by five reviewers blinded to level of expertise and a consensus conference. We tested these performance metrics in 12 surgical residents (Year 3-7) before and 2 weeks after vascular exposure skills training in the Advanced Surgical Skills for Exposure in Trauma (ASSET) course. Performance was assessed in three areas as follows: knowledge (anatomic, management), procedure steps, and technical skills. Time to completion of procedures was recorded, and these metrics were combined into a single performance score, the Trauma Readiness Index (TRI). Wilcoxon matched-pairs signed-ranks test compared pretraining/posttraining effects. Mean time to complete procedures decreased by 4.3 minutes (from 13.4 minutes to 9.1 minutes). The performance component most improved by the 1-day skills training was procedure steps, completion of which increased by 21%. Technical skill scores improved by 12%. Overall knowledge improved by 3%, with 18% improvement in anatomic knowledge. TRI increased significantly from 50% to 64% with ASSET training. Interrater reliability of the surgical performance assessment metrics was validated with single intraclass correlation coefficient of 0.7 to 0.98. A trauma-relevant surgical performance assessment detected improvements in specific procedure steps and anatomic knowledge taught during a 1-day course, quantified by the TRI. ASSET training reduced time to complete vascular control by one third. Future applications include assessing specific skills in a larger surgeon cohort, assessing military surgical readiness, and quantifying skill degradation with time since training.

  4. Exercise testing after beta-blockade: improved specificity and predictive value in detecting coronary heart disease.

    PubMed Central

    Marcomichelakis, J; Donaldson, R; Green, J; Joseph, S; Kelly, H B; Taggart, P; Somerville, W

    1980-01-01

    The value of exercise testing in detecting myocardial ischaemia resulting from coronary atheroma remains controversial. In order to increase the reliability of exercise testing, all its components (asymptomatic, haemodynamic, and electrocardiographic) have been scrutinised. In this study, concerned only with the electrocardiographic response to exercise, the incorporation of beta-blockade into the standard exercise procedure has improved specificity and predictive value without affecting sensitivity. Fifty patients with anginal pain and 50 asymptomatic subjects with an abnormal electrocardiogram were investigated by exercise testing before and after beta-blockade (oxprenolol). All subjects had coronary arteriograms and left ventriculograms, and the results of exercise testing were related to the presence or absence of obstructive coronary artery disease. Possible causes of false positive exercise tests were eliminated by echocardiography. Though beta-blockade was unreliable in distinguishing ischaemic from non-ischaemic resting electrocardiograms, it eliminated all the false positive electrocardiographic responses to exercise in both groups and did not abolish any of the true positive electrocardiographic responses. Thus, specificity and predictive value were improved without reduction in sensitivity. This technique may not necessarily be applicable to other groups of patients or to a random population, but the results of this study suggest it will be a useful additional routine procedure in the investigation of coronary heart disease. PMID:7437172

  5. Benchmarking Procedures for High-Throughput Context Specific Reconstruction Algorithms

    PubMed Central

    Pacheco, Maria P.; Pfau, Thomas; Sauter, Thomas

    2016-01-01

    Recent progress in high-throughput data acquisition has shifted the focus from data generation to processing and understanding of how to integrate collected information. Context specific reconstruction based on generic genome scale models like ReconX or HMR has the potential to become a diagnostic and treatment tool tailored to the analysis of specific individuals. The respective computational algorithms require a high level of predictive power, robustness and sensitivity. Although multiple context specific reconstruction algorithms were published in the last 10 years, only a fraction of them is suitable for model building based on human high-throughput data. Beside other reasons, this might be due to problems arising from the limitation to only one metabolic target function or arbitrary thresholding. This review describes and analyses common validation methods used for testing model building algorithms. Two major methods can be distinguished: consistency testing and comparison based testing. The first is concerned with robustness against noise, e.g., missing data due to the impossibility to distinguish between the signal and the background of non-specific binding of probes in a microarray experiment, and whether distinct sets of input expressed genes corresponding to i.e., different tissues yield distinct models. The latter covers methods comparing sets of functionalities, comparison with existing networks or additional databases. We test those methods on several available algorithms and deduce properties of these algorithms that can be compared with future developments. The set of tests performed, can therefore serve as a benchmarking procedure for future algorithms. PMID:26834640

  6. 40 CFR 86.1513 - Fuel specifications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Fuel specifications. 86.1513 Section 86.1513 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED..., and Liquefied Petroleum Gas-Fueled Diesel-Cycle Light-Duty Trucks; Idle Test Procedures § 86.1513 Fuel...

  7. A closer look at diagnosis in clinical dental practice: part 1. Reliability, validity, specificity and sensitivity of diagnostic procedures.

    PubMed

    Pretty, Iain A; Maupomé, Gerardo

    2004-04-01

    Dentists are involved in diagnosing disease in every aspect of their clinical practice. A range of tests, systems, guides and equipment--which can be generally referred to as diagnostic procedures--are available to aid in diagnostic decision making. In this era of evidence-based dentistry, and given the increasing demand for diagnostic accuracy and properly targeted health care, it is important to assess the value of such diagnostic procedures. Doing so allows dentists to weight appropriately the information these procedures supply, to purchase new equipment if it proves more reliable than existing equipment or even to discard a commonly used procedure if it is shown to be unreliable. This article, the first in a 6-part series, defines several concepts used to express the usefulness of diagnostic procedures, including reliability and validity, and describes some of their operating characteristics (statistical measures of performance), in particular, specificity and sensitivity. Subsequent articles in the series will discuss the value of diagnostic procedures used in daily dental practice and will compare today's most innovative procedures with established methods.

  8. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Report: Initial Comprehensive Performance Test Report, P/N 1331200-2-IT, S/N 105/A2

    NASA Technical Reports Server (NTRS)

    Platt, R.

    1999-01-01

    This is the Performance Verification Report, Initial Comprehensive Performance Test Report, P/N 1331200-2-IT, S/N 105/A2, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A). The specification establishes the requirements for the Comprehensive Performance Test (CPT) and Limited Performance Test (LPT) of the Advanced Microwave Sounding, Unit-A2 (AMSU-A2), referred to herein as the unit. The unit is defined on Drawing 1331200. 1.2 Test procedure sequence. The sequence in which the several phases of this test procedure shall take place is shown in Figure 1, but the sequence can be in any order.

  9. Impact of changes in profile measurement technology on QA testing of pavement smoothness : project summary.

    DOT National Transportation Integrated Search

    2013-08-31

    For quality assurance testing, the Texas Department of Transportations (TxDOTs) Item 585 ride specification includes pay adjustment schedules that are tied to the average international roughness index (IRI), and a procedure to locate defects ba...

  10. 40 CFR 1065.122 - Engine cooling and lubrication.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....122 Section 1065.122 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Equipment Specifications § 1065.122 Engine cooling and lubrication. (a) Engine cooling. Cool the engine during testing so its intake-air, oil, coolant, block, and...

  11. 40 CFR 1065.122 - Engine cooling and lubrication.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....122 Section 1065.122 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Equipment Specifications § 1065.122 Engine cooling and lubrication. (a) Engine cooling. Cool the engine during testing so its intake-air, oil, coolant, block, and...

  12. 40 CFR 1065.122 - Engine cooling and lubrication.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ....122 Section 1065.122 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Equipment Specifications § 1065.122 Engine cooling and lubrication. (a) Engine cooling. Cool the engine during testing so its intake-air, oil, coolant, block, and...

  13. 40 CFR 1065.122 - Engine cooling and lubrication.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ....122 Section 1065.122 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Equipment Specifications § 1065.122 Engine cooling and lubrication. (a) Engine cooling. Cool the engine during testing so its intake-air, oil, coolant, block, and...

  14. 40 CFR 1065.122 - Engine cooling and lubrication.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ....122 Section 1065.122 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Equipment Specifications § 1065.122 Engine cooling and lubrication. (a) Engine cooling. Cool the engine during testing so its intake-air, oil, coolant, block, and...

  15. Draw forming of scale shuttle external tank dome gores

    NASA Technical Reports Server (NTRS)

    Garfield, G.

    1974-01-01

    The process for manufacturing external tank dome gores is discussed. The test fixture and test procedure are described. The characteristics of the draw forming die are analyzed. The specific subjects included are: (1) forming, (2) trimming, (3) cleaning, and (4) heat treatment.

  16. Provision of specific dental procedures by general dentists in the National Dental Practice-Based Research Network: questionnaire findings.

    PubMed

    Gilbert, Gregg H; Gordan, Valeria V; Korelitz, James J; Fellows, Jeffrey L; Meyerowitz, Cyril; Oates, Thomas W; Rindal, D Brad; Gregory, Randall J

    2015-01-22

    Objectives were to: (1) determine whether and how often general dentists (GDs) provide specific dental procedures; and (2) test the hypothesis that provision is associated with key dentist, practice, and patient characteristics. GDs (n = 2,367) in the United States National Dental Practice-Based Research Network completed an Enrollment Questionnaire that included: (1) dentist; (2) practice; and (3) patient characteristics, and how commonly they provide each of 10 dental procedures. We determined how commonly procedures were provided and tested the hypothesis that provision was substantively related to the three sets of characteristics. Two procedure categories were classified as "uncommon" (orthodontics, periodontal surgery), three were "common" (molar endodontics; implants; non-surgical periodontics), and five were "very common" (restorative; esthetic procedures; extractions; removable prosthetics; non-molar endodontics). Dentist, practice, and patient characteristics were substantively related to procedure provision; several characteristics seemed to have pervasive effects, such as dentist gender, training after dental school, full-time/part-time status, private practice vs. institutional practice, presence of a specialist in the same practice, and insurance status of patients. As a group, GDs provide a comprehensive range of procedures. However, provision by individual dentists is substantively related to certain dentist, practice, and patient characteristics. A large number and broad range of factors seem to influence which procedures GDs provide. This may have implications for how GDs respond to the ever-changing landscape of dental care utilization, patient population demography, scope of practice, delivery models and GDs' evolving role in primary care.

  17. [Penicillin allergy as a diagnostic problem. Overview and personal studies].

    PubMed

    Walker, T; Jung, E G; Bayerl, C

    2000-11-01

    Penicillin allergy is a common clinical problem. The distinction between penicillin and para-infectious exanthems is difficult. We investigated the reliability of the history, as well as the sensitivity and specificity of skin tests and specific IgE levels. 160 patients with a history of penicillin allergy were retrospectively evaluated in the outpatient department of a dermatological clinic. Nearly 50% were diagnosed as allergic to penicillin by detection of specific IgE or skin test. About 60% of the patients with immediate type reactions, and 72% with maculo-papular erythema showed positive reactions in skin tests. Significantly more patients were diagnosed as allergic to penicillin by intradermal testing than by prick testing (p < 0.05). The sensitivity of the specific IgE RAST was 17.9%; the specifity, 89.5%. For the prick test the sensitivity was 8.2%; the specificity 90.8%. For the intradermal test the sensitivity was 26%; the specifity 69.7%. We suggest a step by step procedure to detect penicillin allergy making the diagnostic results as valid as possible.

  18. A combination of direct viable count and fluorescence in situ hybridization for specific enumeration of viable Lactobacillus delbrueckii subsp.bulgaricus and Streptococcus thermophilus.

    PubMed

    García-Hernández, J; Moreno, Y; Amorocho, C M; Hernández, M

    2012-03-01

    We have developed a direct viable count (DVC)-FISH procedure for quickly and easily discriminating between viable and nonviable cells of Lactobacillus delbrueckii subsp. bulgaricus and Streptococcus thermophilus strains, the traditional yogurt bacteria. direct viable count method has been modified and adapted for Lact. delbrueckii subsp. bulgaricus and Strep. thermophilus analysis by testing different times of incubation and concentrations of DNA-gyrase inhibitors. DVC procedure has been combined with fluorescent in situ hybridization (FISH) for the specific detection of viable cells of both bacteria with specific rRNA oligonucleotide probes (DVC-FISH). Of the four antibiotics tested (novobiocin, nalidixic acid, pipemidic acid and ciprofloxacin), novobiocin was the most effective for DVC method and the optimum incubation time was 7 h for both bacteria. The number of viable cells was obtained by the enumeration of specific hybridized cells that were elongated at least twice their original length for Lactobacillus and twice their original size for Streptococcus. This technique was successfully applied to detect viable cells in inoculated faeces. Results showed that this DVC-FISH procedure is a quick and culture-independent useful method to specifically detect viable Lact. delbrueckii subsp. bulgaricus and Strep. thermophilus in different samples, being applied for the first time to lactic acid bacteria. © 2011 The Authors. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.

  19. Usefulness of Canadian Public Health Insurance Administrative Databases to Assess Breast and Ovarian Cancer Screening Imaging Technologies for BRCA1/2 Mutation Carriers.

    PubMed

    Larouche, Geneviève; Chiquette, Jocelyne; Plante, Marie; Pelletier, Sylvie; Simard, Jacques; Dorval, Michel

    2016-11-01

    In Canada, recommendations for clinical management of hereditary breast and ovarian cancer among individuals carrying a deleterious BRCA1 or BRCA2 mutation have been available since 2007. Eight years later, very little is known about the uptake of screening and risk-reduction measures in this population. Because Canada's public health care system falls under provincial jurisdictions, using provincial health care administrative databases appears a valuable option to assess management of BRCA1/2 mutation carriers. The objective was to explore the usefulness of public health insurance administrative databases in British Columbia, Ontario, and Quebec to assess management after BRCA1/2 genetic testing. Official public health insurance documents were considered potentially useful if they had specific procedure codes, and pertained to procedures performed in the public and private health care systems. All 3 administrative databases have specific procedures codes for mammography and breast ultrasounds. Only Quebec and Ontario have a specific procedure code for breast magnetic resonance imaging. It is impossible to assess, on an individual basis, the frequency of others screening exams, with the exception of CA-125 testing in British Columbia. Screenings done in private practice are excluded from the administrative databases unless covered by special agreements for reimbursement, such as all breast imaging exams in Ontario and mammograms in British Columbia and Quebec. There are no specific procedure codes for risk-reduction surgeries for breast and ovarian cancer. Population-based assessment of breast and ovarian cancer risk management strategies other than mammographic screening, using only administrative data, is currently challenging in the 3 Canadian provinces studied. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  20. 49 CFR 178.338-16 - Inspection and testing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Inspection and testing. 178.338-16 Section 178.338... PACKAGINGS Specifications for Containers for Motor Vehicle Transportation § 178.338-16 Inspection and testing... Section VIII of the ASME Code. The welder and the welding procedure must be qualified in accordance with...

  1. 'Buildings in Use' Study. Technical Factors.

    ERIC Educational Resources Information Center

    Wisconsin Univ., Milwaukee. School of Architecture and Urban Planning.

    The second report of the 'Buildings in Use' study documents the results of over 100 field tests conducted at four elementary schools, as well as discussion of these results and relevant technical specifications and details. The procedural framework used in the Field Tests Manual is followed and test results are rated numerically wherever possible.…

  2. 14 CFR Appendix F to Part 23 - Test Procedure

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... materials used in electrical wire and cable insulation and in small parts, materials must be tested either... wire and cable insulation, the wire and cable specimens must be the same size as used in the airplane... specification (make and size) must be tested. The specimen of wire or cable (including insulation) must be...

  3. 46 CFR 159.005-9 - Approval inspections and tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Approval inspections and tests. 159.005-9 Section 159.005-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND MATERIALS Approval Procedures § 159.005-9 Approval inspections and tests. (a) Each...

  4. 46 CFR 159.005-9 - Approval inspections and tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Approval inspections and tests. 159.005-9 Section 159.005-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND MATERIALS Approval Procedures § 159.005-9 Approval inspections and tests. (a) Each...

  5. Image-Based Patient-Specific Ventricle Models with Fluid-Structure Interaction for Cardiac Function Assessment and Surgical Design Optimization

    PubMed Central

    Tang, Dalin; Yang, Chun; Geva, Tal; del Nido, Pedro J.

    2010-01-01

    Recent advances in medical imaging technology and computational modeling techniques are making it possible that patient-specific computational ventricle models be constructed and used to test surgical hypotheses and replace empirical and often risky clinical experimentation to examine the efficiency and suitability of various reconstructive procedures in diseased hearts. In this paper, we provide a brief review on recent development in ventricle modeling and its potential application in surgical planning and management of tetralogy of Fallot (ToF) patients. Aspects of data acquisition, model selection and construction, tissue material properties, ventricle layer structure and tissue fiber orientations, pressure condition, model validation and virtual surgery procedures (changing patient-specific ventricle data and perform computer simulation) were reviewed. Results from a case study using patient-specific cardiac magnetic resonance (CMR) imaging and right/left ventricle and patch (RV/LV/Patch) combination model with fluid-structure interactions (FSI) were reported. The models were used to evaluate and optimize human pulmonary valve replacement/insertion (PVR) surgical procedure and patch design and test a surgical hypothesis that PVR with small patch and aggressive scar tissue trimming in PVR surgery may lead to improved recovery of RV function and reduced stress/strain conditions in the patch area. PMID:21344066

  6. Analytical control test plan and microbiological methods for the water recovery test

    NASA Technical Reports Server (NTRS)

    Traweek, M. S. (Editor); Tatara, J. D. (Editor)

    1994-01-01

    Qualitative and quantitative laboratory results are important to the decision-making process. In some cases, they may represent the only basis for deciding between two or more given options or processes. Therefore, it is essential that handling of laboratory samples and analytical operations employed are performed at a deliberate level of conscientious effort. Reporting erroneous results can lead to faulty interpretations and result in misinformed decisions. This document provides analytical control specifications which will govern future test procedures related to all Water Recovery Test (WRT) Phase 3 activities to be conducted at the National Aeronautics and Space Administration/Marshall Space Flight Center (NASA/MSFC). This document addresses the process which will be used to verify analytical data generated throughout the test period, and to identify responsibilities of key personnel and participating laboratories, the chains of communication to be followed, and ensure that approved methodology and procedures are used during WRT activities. This document does not outline specifics, but provides a minimum guideline by which sampling protocols, analysis methodologies, test site operations, and laboratory operations should be developed.

  7. Battery Test Manual For Plug-In Hybrid Electric Vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeffrey R. Belt

    2010-09-01

    This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Program. It is based on technical targets established for energy storage development projects aimed at meeting system level DOE goals for Plug-in Hybrid Electric Vehicles (PHEV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for PHEV’s. However, it does share some methods described in the previously published battery test manual for power-assist hybrid electric vehicles. Due to the complexity of some of the proceduresmore » and supporting analysis, a revision including some modifications and clarifications of these procedures is expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices.« less

  8. Battery Test Manual For Plug-In Hybrid Electric Vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeffrey R. Belt

    2010-12-01

    This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Program. It is based on technical targets established for energy storage development projects aimed at meeting system level DOE goals for Plug-in Hybrid Electric Vehicles (PHEV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for PHEV’s. However, it does share some methods described in the previously published battery test manual for power-assist hybrid electric vehicles. Due to the complexity of some of the proceduresmore » and supporting analysis, a revision including some modifications and clarifications of these procedures is expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices.« less

  9. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Test Report, Electromagnetic Interference (EMI)/Electromagnetic Radiation(EMR) and Electromagnetic Capability (EMC) for the EOS/AMSU-A1

    NASA Technical Reports Server (NTRS)

    Paliwoda, L.

    1998-01-01

    This document contains the procedure and the test results of the Advanced Microwave Sounding Unit-A (AMSU-A) Earth Observing System (EOS) Project, assembly part number 1356008-1, serial number 202, Electromagnetic Interference (EMI) and Electromagnetic Susceptibility (EMC) qualification test. The test was conducted in accordance with the approved EMI/EMC Test Plan/Procedure, Specification number AE-26151/8B, dated 10 September 1998. Aerojet intends that the presentation and submittal of this document, prepared in accordance with the objectives established by the aforementioned Test Plan/Procedure, document number AE-26151/8B, will satisfy the data requirement with respect to the AMSU-A/EOS instrument operational compliance of the EMI/EMC test requirement. Test for the AMSU-A/EOS instrument have been completed and all the requirements per General Interface Requirement Document (GIRD), GSFC 422-11-12-01, for EOS Common Spacecraft/Instruments, paragraph 10.11, were met with the exceptions of the test methods CE03, RE01, and RE02, as described in this document.

  10. Vascular Access Procedures

    MedlinePlus

    ... have a personal story about radiology? Share your patient story here Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  11. Guidelines for testing and release procedures

    NASA Technical Reports Server (NTRS)

    Molari, R.; Conway, M.

    1984-01-01

    Guidelines and procedures are recommended for the testing and release of the types of computer software efforts commonly performed at NASA/Ames Research Center. All recommendations are based on the premise that testing and release activities must be specifically selected for the environment, size, and purpose of each individual software project. Guidelines are presented for building a Test Plan and using formal Test Plan and Test Care Inspections on it. Frequent references are made to NASA/Ames Guidelines for Software Inspections. Guidelines are presented for selecting an Overall Test Approach and for each of the four main phases of testing: (1) Unit Testing of Components, (2) Integration Testing of Components, (3) System Integration Testing, and (4) Acceptance Testing. Tools used for testing are listed, including those available from operating systems used at Ames, specialized tools which can be developed, unit test drivers, stub module generators, and the use of format test reporting schemes.

  12. An Assessment Program Designed To Improve Communication Instruction through a Competency-Based Core Curriculum.

    ERIC Educational Resources Information Center

    Aitken, Joan E.; Neer, Michael R.

    This paper provides an example procedure used to design and install a program of assessment to improve communication instruction through a competency-based core curriculum at a mid-sized, urban university. The paper models the various steps in the process, and includes specific tests, forms, memos, course description, sources, and procedures which…

  13. AUTOMOTIVE DIESEL MAINTENANCE 2. UNIT XIII, BATTERY SERVICE AND TESTING PROCEDURES--PART II.

    ERIC Educational Resources Information Center

    Human Engineering Inst., Cleveland, OH.

    THIS MODULE OF A 25-MODULE COURSE IS DESIGNED TO FAMILIARIZE THE TRAINEE WITH PROCEDURES FOR SERVICING LEAD-ACID STORAGE BATTERIES USED ON DIESEL POWERED EQUIPMENT. TOPICS ARE (1) ELECTROLYTE AND SPECIFIC GRAVITY, (2) BATTERY CHARGING, (3) STORAGE BATTERY TYPES AND DESIGN, (4) BATTERY CAPACITY RATINGS, (5) BATTERY INSTALLATION, SERVICING, AND…

  14. 77 FR 8238 - Notice of Petition for Waiver of GE Appliances From the Department of Energy Residential...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-14

    ... of Energy (DOE) test procedure for determining the energy consumption of certain specific electric... procedures may evaluate the basic model in a manner so unrepresentative of its true energy consumption... in a manner representative of its energy consumption. 10 CFR 430.27(b)(1)(iii). The Assistant...

  15. Sampling. Operational Control Tests for Wastewater Treatment Facilities. Instructor's Manual [and] Student Workbook.

    ERIC Educational Resources Information Center

    Carnegie, John W.

    A brief overview of the basic concepts and philosophies for sampling water and waste water systems is presented in this module. The module is not intended to specify sampling procedures, frequencies, or locations for specific treatment facilities but rather to outline those general procedures which should be followed when sampling under most…

  16. Bayesian SEM for Specification Search Problems in Testing Factorial Invariance.

    PubMed

    Shi, Dexin; Song, Hairong; Liao, Xiaolan; Terry, Robert; Snyder, Lori A

    2017-01-01

    Specification search problems refer to two important but under-addressed issues in testing for factorial invariance: how to select proper reference indicators and how to locate specific non-invariant parameters. In this study, we propose a two-step procedure to solve these issues. Step 1 is to identify a proper reference indicator using the Bayesian structural equation modeling approach. An item is selected if it is associated with the highest likelihood to be invariant across groups. Step 2 is to locate specific non-invariant parameters, given that a proper reference indicator has already been selected in Step 1. A series of simulation analyses show that the proposed method performs well under a variety of data conditions, and optimal performance is observed under conditions of large magnitude of non-invariance, low proportion of non-invariance, and large sample sizes. We also provide an empirical example to demonstrate the specific procedures to implement the proposed method in applied research. The importance and influences are discussed regarding the choices of informative priors with zero mean and small variances. Extensions and limitations are also pointed out.

  17. 40 CFR 86.213-04 - Fuel specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1994 and Later Model Year Gasoline-Fueled New Light-Duty Vehicles, New Light-Duty Trucks and New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.213-04 Fuel specifications. Gasoline...

  18. 40 CFR 86.213-94 - Fuel specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1994 and Later Model Year Gasoline-Fueled New Light-Duty Vehicles, New Light-Duty Trucks and New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.213-94 Fuel specifications. Gasoline...

  19. Development of Subscale Fast Cookoff Test (PREPRINT)

    DTIC Science & Technology

    2006-09-21

    The hazards classification procedures have been harmonized with both the UN Test and Criteria Manual for UN Series 1...aimed at the development of a sub-scale alternate test protocol to the external fire test currently required for final hazards classification (HC...external fire test currently required for final hazards classification (HC) of an ordnance system. The specific goal of this part of the task was

  20. Welding procedure specification. Supplement 1. Records of procedure qualification tests. Gas tungsten arc welding of aluminum alloys 3004, 5052, and 5X54

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wodtke, C.H.; Frizzell, D.R.; Plunkett, W.A.

    1986-06-01

    Procedure WPS-1002 is qualified under Section IX of the ASME Boiler and Pressure Vessel Code for gas tungsten arc welding of aluminum alloys 3004, 5052, 5154, and 5454 (P-22), in thickness range 0.062 to 0.5 inches; filler metal is ER4043 (F-23) for 3004, and ER5356 (F-22) for other alloys; shielding gas is argon.

  1. 40 CFR 91.404 - Test procedure overview.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... analyzed through the analytical system. (b) The tests are designed to determine the brake-specific... four power modes with an exponential relationship between torque and speed which span the typical... the concentration of each pollutant, fuel flow, and the power output during each mode. The measured...

  2. 40 CFR 86.1313-2004 - Fuel specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate Exhaust Test Procedures... Administrator in exhaust and evaporative emission testing of petroleum-fueled Otto-cycle engines, except that...

  3. 40 CFR 86.1313-2004 - Fuel specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate Exhaust Test Procedures... Administrator in exhaust and evaporative emission testing of petroleum-fueled Otto-cycle engines, except that...

  4. 40 CFR 86.1313-2004 - Fuel specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate Exhaust Test Procedures... Administrator in exhaust and evaporative emission testing of petroleum-fueled Otto-cycle engines, except that...

  5. 40 CFR 86.1313-2004 - Fuel specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate Exhaust Test Procedures... Administrator in exhaust and evaporative emission testing of petroleum-fueled Otto-cycle engines, except that...

  6. DESIGN CRITERIA FOR HIGH TEMPERATURE LATTICE TEST REACTOR PROJECT CAH-100

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ballard, D.L.; Brown, W.W.; Harrison, C.W.

    Design and construction specifications to be followed in the development of the reactor, its associated systems and experimental facilities, and the housing and required services for the facility are presented. The testing procedures to be used are outlined. (D.C.W.)

  7. 40 CFR 90.404 - Test procedure overview.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust... engine operating conditions to be conducted on an engine dynamometer or equivalent load and speed... also designed to determine the brake-specific emissions of non-methane hydrocarbons. The test consists...

  8. 40 CFR 90.404 - Test procedure overview.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust... engine operating conditions to be conducted on an engine dynamometer or equivalent load and speed... also designed to determine the brake-specific emissions of non-methane hydrocarbons. The test consists...

  9. 40 CFR 90.404 - Test procedure overview.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust... engine operating conditions to be conducted on an engine dynamometer or equivalent load and speed... also designed to determine the brake-specific emissions of non-methane hydrocarbons. The test consists...

  10. 40 CFR 90.404 - Test procedure overview.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust... engine operating conditions to be conducted on an engine dynamometer or equivalent load and speed... also designed to determine the brake-specific emissions of non-methane hydrocarbons. The test consists...

  11. Regents Examinations and Competency Tests: School Administrator's Manual. 1981 Edition.

    ERIC Educational Resources Information Center

    New York State Education Dept., Albany. Bureau of Elementary and Secondary Educational Testing.

    Intended for use by school administrators, guidance counselors, teachers, and proctors, this manual contains general information on Regents examinations and competency tests. Specifically, the regulations and procedures for ordering, administering, and rating these examinations are described. Information is also included about the competency…

  12. Regents Examinations & Competency Tests: School Administrator's Manual. 1983 Edition.

    ERIC Educational Resources Information Center

    New York State Education Dept., Albany. Bureau of Elementary and Secondary Testing Programs.

    Intended for use by school administrators, guidance counselors, teachers, and proctors, this manual contains general information on Regents examinations and competency tests. Specifically, the regulations and procedures for ordering, administering, rating, and reporting results of these examinations are described. Information is also included…

  13. 40 CFR 86.1360-2007 - Supplemental emission test; test cycle and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) * (MZ-MRS) / (MTU-MRS) ETU = ET + (EU-ET) * (nZ-nRT) / (nSU-nRT) ERS = ER + (ES-ER) * (nZ-nRT) / (nSU-n..., ET, EU = for each regulated pollutant, brake specific gaseous emissions of the enveloping modes...

  14. Predicting Performance in Higher Education Using Proximal Predictors.

    PubMed

    Niessen, A Susan M; Meijer, Rob R; Tendeiro, Jorge N

    2016-01-01

    We studied the validity of two methods for predicting academic performance and student-program fit that were proximal to important study criteria. Applicants to an undergraduate psychology program participated in a selection procedure containing a trial-studying test based on a work sample approach, and specific skills tests in English and math. Test scores were used to predict academic achievement and progress after the first year, achievement in specific course types, enrollment, and dropout after the first year. All tests showed positive significant correlations with the criteria. The trial-studying test was consistently the best predictor in the admission procedure. We found no significant differences between the predictive validity of the trial-studying test and prior educational performance, and substantial shared explained variance between the two predictors. Only applicants with lower trial-studying scores were significantly less likely to enroll in the program. In conclusion, the trial-studying test yielded predictive validities similar to that of prior educational performance and possibly enabled self-selection. In admissions aimed at student-program fit, or in admissions in which past educational performance is difficult to use, a trial-studying test is a good instrument to predict academic performance.

  15. How to report and interpret screening test properties: guidelines for driving researchers.

    PubMed

    Weaver, Bruce; Walter, Stephen D; Bédard, Michel

    2014-01-01

    One important goal of driving research is the development of a short but valid office-based screening test for fitness to drive of aging drivers. Several candidate tests have been proposed already, and no doubt others will be proposed in the future. It might seem obvious that authors advocating for the adoption of a particular screening test or procedure should report sensitivity, specificity, and other common screening test properties. Unfortunately, driving researchers have frequently failed to report any screening test properties. Others have reported screening test properties but have made basic mistakes such as calculating predictive values of positive and negative tests but reporting them incorrectly as sensitivity and specificity. These omissions and errors suggest that some driving researchers may be unaware of the importance of accurately reporting test properties when proposing a screening procedure and that others may need a refresher on how to calculate and interpret the most common screening test properties. Many good learning resources for screening and diagnostic tests are available, but most of them are intended for students and researchers in medicine, epidemiology, or public health. We hope that this tutorial in a prominent transportation journal will help lead to improved reporting and interpretation of screening test properties in articles that assess the usefulness of potential screening tools for fitness to drive.

  16. A Measurement Plane for Optical Networks to Manage Emergency Events

    NASA Astrophysics Data System (ADS)

    Tego, E.; Carciofi, C.; Grazioso, P.; Petrini, V.; Pompei, S.; Matera, F.; Attanasio, V.; Nastri, E.; Restuccia, E.

    2017-11-01

    In this work, we show a wide geographical area optical network test bed, adopting the mPlane measurement plane for monitoring its performance and to manage software defined network approaches, with some specific tests and procedures dedicated to respond to disaster events and to support emergency networks. Such a test bed includes FTTX accesses, and it is currently implemented to support future 5G wireless services with slicing procedures based on Carrier Ethernet. The characteristics of this platform have been experimentally tested in the case of a damage-causing link failure and traffic congestion, showing a fast reactions to these disastrous events, allowing the user to recharge the initial QoS parameters.

  17. Recommended fine positioning test for the Development Test Flight (DTF-1) of the NASA Flight Telerobotic Servicer (FTS)

    NASA Technical Reports Server (NTRS)

    Dagalakis, N.; Wavering, A. J.; Spidaliere, P.

    1991-01-01

    Test procedures are proposed for the NASA DTF (Development Test Flight)-1 positioning tests of the FTS (Flight Telerobotic Servicer). The unique problems associated with the DTF-1 mission are discussed, standard robot performance tests and terminology are reviewed and a very detailed description of flight-like testing and analysis is presented. The major technical problem associated with DTF-1 is that only one position sensor can be used, which will be fixed at one location, with a working volume which is probably smaller than some of the robot errors to be measured. Radiation heating of the arm and the sensor could also cause distortions that would interfere with the test. Two robot performance testing committees have established standard testing procedures relevant to the DTF-1. Due to the technical problems associated with DTF-1, these procedures cannot be applied directly. These standard tests call for the use of several test positions at specific locations. Only one position, that of the position sensor, can be used by DTF-1. Off-line programming accuracy might be impossible to measure and in that case it will have to be replaced by forward kinetics accuracy.

  18. 40 CFR 86.313-79 - Air flow measurement specifications; diesel engines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...; diesel engines. 86.313-79 Section 86.313-79 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Emission Regulations for New Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86.313-79 Air flow measurement specifications; diesel engines. (a) The air flow measurement...

  19. 40 CFR 86.313-79 - Air flow measurement specifications; diesel engines.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...; diesel engines. 86.313-79 Section 86.313-79 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Emission Regulations for New Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86.313-79 Air flow measurement specifications; diesel engines. (a) The air flow measurement...

  20. 40 CFR 90.416 - Intake air flow measurement specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Intake air flow measurement... Gaseous Exhaust Test Procedures § 90.416 Intake air flow measurement specifications. (a) If used, the engine intake air flow measurement method used must have a range large enough to accurately measure the...

  1. 40 CFR 86.313-79 - Air flow measurement specifications; diesel engines.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...; diesel engines. 86.313-79 Section 86.313-79 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Emission Regulations for New Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86.313-79 Air flow measurement specifications; diesel engines. (a) The air flow measurement...

  2. 40 CFR 86.313-79 - Air flow measurement specifications; diesel engines.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...; diesel engines. 86.313-79 Section 86.313-79 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Emission Regulations for New Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86.313-79 Air flow measurement specifications; diesel engines. (a) The air flow measurement...

  3. 40 CFR Appendix E to Part 52 - Performance Specifications and, Specification Test Procedures for Monitoring Systems for Effluent...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... rate at the time of the measurements is zero. 3.4Calibration drift. The change in measurement system... reference value (paragraph 6.3.1). Zero drift (24 hours) zero drift, calibration drift, and operation period. 5.1.1System...

  4. 40 CFR Appendix E to Part 52 - Performance Specifications and, Specification Test Procedures for Monitoring Systems for Effluent...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... rate at the time of the measurements is zero. 3.4Calibration drift. The change in measurement system... reference value (paragraph 6.3.1). Zero drift (24 hours) zero drift, calibration drift, and operation period. 5.1.1System...

  5. 40 CFR Appendix E to Part 52 - Performance Specifications and, Specification Test Procedures for Monitoring Systems for Effluent...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... rate at the time of the measurements is zero. 3.4Calibration drift. The change in measurement system... reference value (paragraph 6.3.1). Zero drift (24 hours) zero drift, calibration drift, and operation period. 5.1.1System...

  6. RFI simulation definition study, exhibit D

    NASA Technical Reports Server (NTRS)

    Braun, W. R.

    1981-01-01

    Comparative analyses of experimental and predicted effects of the radio frequency interference (RFI) environment on the Shuttle/TDRSS S-band links were performed. Specifications are defined ad ESTL test requirements are presented. Procedures for using the RFI test generator in the ESTL S-band link tests are presented and performance predictions for these links in the RFI environment are provided.

  7. 75 FR 64737 - Automated Commercial Environment (ACE): Announcement of a National Customs Automation Program...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-20

    ... Commissioner of CBP with authority to conduct limited test programs or procedures designed to evaluate planned.... Specifically, CBP is looking for test participants to include: 2-3 Ocean Carriers. At least one must be filing... their software ready to test with CBP once CBP begins the certification process. CBP will post the...

  8. Development of an Instrument to Evaluate the Knowledge of Elementary Teachers about Venereal Disease.

    ERIC Educational Resources Information Center

    Schmidt, Norma G.

    The purpose of this study was to develop a valid, reliable test to measure the knowledge of elementary school teachers about venereal disease. Recommended scientific test construction procedures were carefully followed. These included the development of a content outline and a table of specification; submitting potential test items to a review…

  9. Individual differences in susceptibility to false memories: The effect of memory specificity.

    PubMed

    Dewhurst, Stephen A; Anderson, Rachel J; Berry, Donna M; Garner, Sarah R

    2017-06-25

    Previous research has highlighted the wide individual variability in susceptibility to the false memories produced by the Deese/Roediger-McDermott (DRM) procedure [Deese, J. (1959). On the prediction of occurrence of particular verbal intrusions in immediate recall. Journal of Experimental Psychology, 58, 17-22; Roediger, H. L., III, & McDermott, K. B. (1995). Creating false memories: Remembering words not presented in lists. Journal of Experimental Psychology: Learning, Memory, & Cognition, 21, 803-814]. The current study investigated whether susceptibility to false memories is influenced by individual differences in the specificity of autobiographical memory retrieval. Memory specificity was measured using the Sentence Completion for Events from the Past Test (SCEPT) [Raes, F., Hermans, D., Williams, J. M. G., & Eelen, P. (2007). A sentence completion procedure as an alternative to the Autobiographical Memory Test for assessing overgeneral memory in non-clinical populations. Memory, 15, 495-507]. Memory specificity did not correlate with correct recognition, but a specific retrieval style was positively correlated with levels of false recognition. It is proposed that the contextual details that frequently accompany false memories of nonstudied lures are more accessible in individuals with specific retrieval styles.

  10. Creep Laboratory manual

    NASA Astrophysics Data System (ADS)

    Osgerby, S.; Loveday, M. S.

    1992-06-01

    A manual for the NPL Creep Laboratory, a collective name given to two testing laboratories, the Uniaxial Creep Laboratory and the Advanced High Temperature Mechanical Testing Laboratory, is presented. The first laboratory is devoted to uniaxial creep testing and houses approximately 50 high sensitivity creep machines including 10 constant stress cam lever machines. The second laboratory houses a low cycle fatigue testing machine of 100 kN capacity driven by a servo-electric actuator, five machines for uniaxial tensile creep testing of engineering ceramics at temperatures up to 1600C, and an electronic creep machine. Details of the operational procedures for carrying out uniaxial creep testing are given. Calibration procedures to be followed in order to comply with the specifications laid down by British standards, and to provide traceability back to the primary standards are described.

  11. Canadian Health Measures Survey pre-test: design, methods, results.

    PubMed

    Tremblay, Mark; Langlois, Renée; Bryan, Shirley; Esliger, Dale; Patterson, Julienne

    2007-01-01

    The Canadian Health Measures Survey (CHMS) pre-test was conducted to provide information about the challenges and costs associated with administering a physical health measures survey in Canada. To achieve the specific objectives of the pre-test, protocols were developed and tested, and methods for household interviewing and clinic testing were designed and revised. The cost, logistics and suitability of using fixed sites for the CHMS were assessed. Although data collection, transfer and storage procedures are complex, the pre-test experience confirmed Statistics Canada's ability to conduct a direct health measures survey and the willingness of Canadians to participate in such a health survey. Many operational and logistical procedures worked well and, with minor modifications, are being employed in the main survey. Fixed sites were problematic, and survey costs were higher than expected.

  12. Generating Nonnormal Multivariate Data Using Copulas: Applications to SEM.

    PubMed

    Mair, Patrick; Satorra, Albert; Bentler, Peter M

    2012-07-01

    This article develops a procedure based on copulas to simulate multivariate nonnormal data that satisfy a prespecified variance-covariance matrix. The covariance matrix used can comply with a specific moment structure form (e.g., a factor analysis or a general structural equation model). Thus, the method is particularly useful for Monte Carlo evaluation of structural equation models within the context of nonnormal data. The new procedure for nonnormal data simulation is theoretically described and also implemented in the widely used R environment. The quality of the method is assessed by Monte Carlo simulations. A 1-sample test on the observed covariance matrix based on the copula methodology is proposed. This new test for evaluating the quality of a simulation is defined through a particular structural model specification and is robust against normality violations.

  13. [Sensitization to chymopapain in patients treated with chemonucleolysis].

    PubMed

    García-Ortega, P; Ramírez Ferreiras, W; Sancho, A; Urías, S; Cisteró, A

    1991-03-23

    Chemonucleolysis (intradisk administration of chymopapain) is a procedure to treat intervertebral disk hernia. Recently, its use has been questioned due to the development of anaphylactic reactions in patients sensitized to chymopapain. The prevalence of sensitization to chymopapain has been evaluated before and after chemonucleolysis, and the possibility to establish risk groups through the allergy history has been assessed. 104 consecutive patients who were candidates to chemonucleolysis were evaluated with an allergy questionnaire, cutaneous tests to aeroallergens and to chymopapain, and chymopapain-specific IgE. The two latter tests were repeated one month after chemonucleolysis. Only 2 patients (1.9%) showed evidence of chymopapain sensitization before the procedure. Sixteen patients (16%) were sensitized after chemonucleolysis. None of the possible risk factors evaluated in the allergy questionnaire (atopy, drug allergy, papaya occupational exposure or use of additives, cosmetics or drugs containing papaine) were significantly related with the risk of sensitization to chymopapain. The prevalence of chymopapain sensitization in the study group was low. The allergy questionnaire (atopy, drug allergy, use of papaya, occupational history did not identify sensitized patients. Cutaneous tests and specific IgE are the best method to detect chymopapain sensitization. The remarkable rate of sensitization after chemonucleolysis may partially limit the usefulness of the procedure.

  14. Several Modified Goodness-Of-Fit Tests for the Cauchy Distribution with Unknown Scale and Location Parameters

    DTIC Science & Technology

    1994-03-01

    labels of a, which is called significance levels. The hypothesis tests are done based on the a levels . The maximum probabilities of making type II error...critical values at specific a levels . This procedure is done for each of the 50,000 samples. The number of the samples passing each test at those specific... a levels is counted. The ratio of the number of accepted samples to 50,000 gives the percentage point. Then, subtracting that value from one would

  15. Facilitating Energy Savings through Enhanced Usability of Thermostats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meier, Alan; Aragon, Cecilia; Peffer, Therese

    2011-05-23

    Residential thermostats play a key role in controlling heating and cooling systems. Occupants often find the controls of programmable thermostats confusing, sometimes leading to higher heating consumption than when the buildings are controlled manually. A high degree of usability is vital to a programmable thermostat's effectiveness because, unlike a more efficient heating system, occupants must engage in specific actions after installation to obtain energy savings. We developed a procedure for measuring the usability of thermostats and tested this methodology with 31 subjects on five thermostats. The procedure requires first identifying representative tasks associated with the device and then testing themore » subjects ability to accomplish those tasks. The procedure was able to demonstrate the subjects wide ability to accomplish tasks and the influence of a device's usability on success rates. A metric based on the time to accomplish the tasks and the fraction of subjects actually completing the tasks captured the key aspects of each thermostat's usability. The procedure was recently adopted by the Energy Star Program for its thermostat specification. The approach appears suitable for quantifying usability of controls in other products, such as heat pump water heaters and commercial lighting.« less

  16. The Effectiveness of a Cognitive Task Analysis Informed Curriculum to Increase Self-Efficacy and Improve Performance for an Open Cricothyrotomy

    DTIC Science & Technology

    2011-01-01

    either the CTA group (n 12) or the control group (n 14). The CTA group learned the open cricothyrotomy procedure using the CTA curriculum. The...completed a 6-item pretest that posed open - ended questions regarding actions and decisions required to conduct the procedure given a specific... posttest assessing their knowl- edge of the procedure. Parallel forms of the pretest and post- test instruments were developed using different case scenar

  17. 40 CFR 600.207-12 - Calculation and use of vehicle-specific 5-cycle-based fuel economy and CO2 emission values for...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... economy and CO2 emission values from the tests performed using gasoline or diesel test fuel. (ii) Calculate the 5-cycle city and highway fuel economy and CO2 emission values from the tests performed using alcohol or natural gas test fuel, if 5-cycle testing has been performed. Otherwise, the procedure in § 600...

  18. 40 CFR 600.207-12 - Calculation and use of vehicle-specific 5-cycle-based fuel economy and CO2 emission values for...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... economy and CO2 emission values from the tests performed using gasoline or diesel test fuel. (ii) Calculate the 5-cycle city and highway fuel economy and CO2 emission values from the tests performed using alcohol or natural gas test fuel, if 5-cycle testing has been performed. Otherwise, the procedure in § 600...

  19. 40 CFR 600.207-12 - Calculation and use of vehicle-specific 5-cycle-based fuel economy and CO2 emission values for...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... economy and CO2 emission values from the tests performed using gasoline or diesel test fuel. (ii) Calculate the 5-cycle city and highway fuel economy and CO2 emission values from the tests performed using alcohol or natural gas test fuel, if 5-cycle testing has been performed. Otherwise, the procedure in § 600...

  20. A Statistical Procedure for Testing Unusually Frequent Exactly Matching Responses and Nearly Matching Responses. Research Report. ETS RR-17-23

    ERIC Educational Resources Information Center

    Haberman, Shelby J.; Lee, Yi-Hsuan

    2017-01-01

    In investigations of unusual testing behavior, a common question is whether a specific pattern of responses occurs unusually often within a group of examinees. In many current tests, modern communication techniques can permit quite large numbers of examinees to share keys, or common response patterns, to the entire test. To address this issue,…

  1. 40 CFR 600.113-08 - Fuel economy calculations for FTP, HFET, US06, SC03 and cold temperature FTP tests.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... EMISSIONS OF MOTOR VEHICLES Fuel Economy and Carbon-Related Exhaust Emission Test Procedures § 600.113-08 Fuel economy calculations for FTP, HFET, US06, SC03 and cold temperature FTP tests. The Administrator... specific gravity, carbon weight fraction and net heating value of the test fuel must be determined. The FTP...

  2. Your First Chiropractic Visit

    MedlinePlus

    ... to general physical examination procedures such as blood pres- sure, pulse, respiration, and temperature, the examina- tion will include specific orthopedic and neurological tests to assess: • Range of motion of the affected ...

  3. Evaluation of molecular markers for Phytophthora ramorum detection and identification: testing for specificity using a standardized library of isolates.

    PubMed

    Martin, F N; Coffey, M D; Zeller, K; Hamelin, R C; Tooley, P; Garbelotto, M; Hughes, K J D; Kubisiak, T; Bilodeau, G J; Levy, L; Blomquist, C; Berger, P H

    2009-04-01

    Given the importance of Phytophthora ramorum from a regulatory standpoint, it is imperative that molecular markers for pathogen detection are fully tested to evaluate their specificity in detection of the pathogen. In an effort to evaluate 11 reported diagnostic techniques, we assembled a standardized DNA library using accessions from the World Phytophthora Genetic Resource Collection for 315 isolates representing 60 described Phytophthora spp. as well as 11 taxonomically unclassified isolates. These were sent blind to collaborators in seven laboratories to evaluate published diagnostic procedures using conventional (based on internal transcribed spacer [ITS] and cytochrome oxidase gene [cox]1 and 2 spacer regions) and real-time polymerase chain reaction (based on ITS and cox1 and 2 spacer regions as well as beta-tubulin and elicitin genes). Single-strand conformation polymorphism (SSCP) analysis using an automated sequencer for data collection was also evaluated for identification of all species tested. In general, the procedures worked well, with varying levels of specificity observed among the different techniques. With few exceptions, all assays correctly identified all isolates of P. ramorum and low levels of false positives were observed for the mitochondrial cox spacer markers and most of the real-time assays based on nuclear markers (diagnostic specificity between 96.9 and 100%). The highest level of false positives was obtained with the conventional nested ITS procedure; however, this technique is not stand-alone and is used in conjunction with two other assays for diagnostic purposes. The results indicated that using multiple assays improved the accuracy of the results compared with looking at a single assay alone, in particular when the markers represented different genetic loci. The SSCP procedure accurately identified P. ramorum and was helpful in classification of a number of isolates to a species level. With one exception, all procedures accurately identified P. ramorum in blind evaluations of 60 field samples that included examples of plant infection by 11 other Phytophthora spp. The SSCP analysis identified eight of these species, with three identified to a species group.

  4. Humidity Effects on Soluble Core Mechanical and Thermal Properties (Polyvinyl Alcohol/Microballoon Composite)

    NASA Technical Reports Server (NTRS)

    1993-01-01

    This document constitutes the final report for the study of humidity effects and loading rate on soluble core (PVA/MB composite material) mechanical and thermal properties. This report describes test results, procedures employed, and any unusual occurrences or specific observations associated with this test program.

  5. 40 CFR 86.884-10 - Information.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 20 2013-07-01 2013-07-01 false Information. 86.884-10 Section 86.884... New Diesel Heavy-Duty Engines; Smoke Exhaust Test Procedure § 86.884-10 Information. The following information, as applicable, shall be recorded for each test: (a) Engine description and specifications. A copy...

  6. 40 CFR 86.884-10 - Information.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Information. 86.884-10 Section 86.884... New Diesel Heavy-Duty Engines; Smoke Exhaust Test Procedure § 86.884-10 Information. The following information, as applicable, shall be recorded for each test: (a) Engine description and specifications. A copy...

  7. 40 CFR 86.884-10 - Information.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Information. 86.884-10 Section 86.884... New Diesel Heavy-Duty Engines; Smoke Exhaust Test Procedure § 86.884-10 Information. The following information, as applicable, shall be recorded for each test: (a) Engine description and specifications. A copy...

  8. Simultaneous Inference Procedures for Means.

    ERIC Educational Resources Information Center

    Krishnaiah, P. R.

    Some aspects of simultaneous tests for means are reviewed. Specifically, the comparison of univariate or multivariate normal populations based on the values of the means or mean vectors when the variances or covariance matrices are equal is discussed. Tukey's and Dunnett's tests for multiple comparisons of means, Scheffe's method of examining…

  9. 40 CFR 86.884-10 - Information.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Information. 86.884-10 Section 86.884... New Diesel Heavy-Duty Engines; Smoke Exhaust Test Procedure § 86.884-10 Information. The following information, as applicable, shall be recorded for each test: (a) Engine description and specifications. A copy...

  10. 40 CFR 86.308-79 - Gas specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... New Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86.308-79... Diesel engine tests the diluent shall be zero-grade air. (3) Calibration or span gases for the NOX...) Alternate pure hydrogen fuel. Some HFID's are designed to operate on pure hydrogen. Generally the HFID fuel...

  11. 40 CFR 86.308-79 - Gas specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... New Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86.308-79... Diesel engine tests the diluent shall be zero-grade air. (3) Calibration or span gases for the NOX...) Alternate pure hydrogen fuel. Some HFID's are designed to operate on pure hydrogen. Generally the HFID fuel...

  12. Safety in the Chemical Laboratory: Tested Disposal Methods for Chemical Wastes from Academic Laboratories.

    ERIC Educational Resources Information Center

    Armour, M. A.; And Others

    1985-01-01

    Describes procedures for disposing of dichromate cleaning solution, picric acid, organic azides, oxalic acid, chemical spills, and hydroperoxides in ethers and alkenes. These methods have been tested under laboratory conditions and are specific for individual chemicals rather than for groups of chemicals. (JN)

  13. Assessment of Second Language Performance.

    ERIC Educational Resources Information Center

    Lumley, Tom

    1996-01-01

    A discussion of current second language testing trends and practices in Australia focuses on the use of performance assessment, providing examples of its application in four specific contexts: an occupational English test used for to assess job-related English language skills as part of the certification procedure for health professionals;…

  14. RANDOMIZATION PROCEDURES FOR THE ANALYSIS OF EDUCATIONAL EXPERIMENTS.

    ERIC Educational Resources Information Center

    COLLIER, RAYMOND O.

    CERTAIN SPECIFIC ASPECTS OF HYPOTHESIS TESTS USED FOR ANALYSIS OF RESULTS IN RANDOMIZED EXPERIMENTS WERE STUDIED--(1) THE DEVELOPMENT OF THE THEORETICAL FACTOR, THAT OF PROVIDING INFORMATION ON STATISTICAL TESTS FOR CERTAIN EXPERIMENTAL DESIGNS AND (2) THE DEVELOPMENT OF THE APPLIED ELEMENT, THAT OF SUPPLYING THE EXPERIMENTER WITH MACHINERY FOR…

  15. 40 CFR 53.62 - Test procedure: Full wind tunnel test.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... distributions to provide six estimates of measured mass concentration. Critical parameters for these idealized... (expressed as a percentage) of the mass concentration of particles of a specific size reaching the sampler filter or filters to the mass concentration of particles of the same size approaching the sampler. (c...

  16. Ultrasound-Guided Breast Biopsy

    MedlinePlus

    ... the type of biopsy being performed or the design of the biopsy machine, a biopsy of tissue ... cost information. The costs for specific medical imaging tests, treatments and procedures may vary by geographic region. ...

  17. 40 CFR 86.316-79 - Carbon monoxide and carbon dioxide analyzer specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Carbon monoxide and carbon dioxide... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND... Test Procedures § 86.316-79 Carbon monoxide and carbon dioxide analyzer specifications. (a) Carbon...

  18. Assessing Disease Class-Specific Diagnostic Ability: A Practical Adaptive Test Approach.

    ERIC Educational Resources Information Center

    Papa, Frank J.; Schumacker, Randall E.

    Measures of the robustness of disease class-specific diagnostic concepts could play a central role in training programs designed to assure the development of diagnostic competence. In the pilot study, the authors used disease/sign-symptom conditional probability estimates, Monte Carlo procedures, and artificial intelligence (AI) tools to create…

  19. Grammar Predicts Procedural Learning and Consolidation Deficits in Children with Specific Language Impairment

    PubMed Central

    Hedenius, Martina; Persson, Jonas; Tremblay, Antoine; Adi-Japha, Esther; Veríssimo, João; Dye, Cristina D.; Alm, Per; Jennische, Margareta; Tomblin, J. Bruce; Ullman, Michael T.

    2011-01-01

    The Procedural Deficit Hypothesis (PDH) posits that Specific Language Impairment (SLI) can be largely explained by abnormalities of brain structures that subserve procedural memory. The PDH predicts impairments of procedural memory itself, and that such impairments underlie the grammatical deficits observed in the disorder. Previous studies have indeed reported procedural learning impairments in SLI, and have found that these are associated with grammatical difficulties. The present study extends this research by examining the consolidation and longer-term procedural sequence learning in children with SLI. The Alternating Serial Reaction Time (ASRT) task was given to children with SLI and typically-developing (TD) children in an initial learning session and an average of three days later to test for consolidation and longer-term learning. Although both groups showed evidence of initial sequence learning, only the TD children showed clear signs of consolidation, even though the two groups did not differ in longer-term learning. When the children were re-categorized on the basis of grammar deficits rather than broader language deficits, a clearer pattern emerged. Whereas both the grammar impaired and normal grammar groups showed evidence of initial sequence learning, only those with normal grammar showed consolidation and longer-term learning. Indeed, the grammar-impaired group appeared to lose any sequence knowledge gained during the initial testing session. These findings held even when controlling for vocabulary or a broad non-grammatical language measure, neither of which were associated with procedural memory. When grammar was examined as a continuous variable over all children, the same relationships between procedural memory and grammar, but not vocabulary or the broader language measure, were observed. Overall, the findings support and further specify the PDH. They suggest that consolidation and longer-term procedural learning are impaired in SLI, but that these impairments are specifically tied to the grammatical deficits in the disorder. The possibility that consolidation and longer-term learning are problematic in the disorder suggests a locus of potential study for therapeutic approaches. In sum, this study clarifies our understanding of the underlying deficits in SLI, and suggests avenues for further research. PMID:21840165

  20. 7 CFR 1755.890 - RUS specification for filled telephone cables with expanded insulation.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) The test procedures described in this appendix are for qualification of initial cable designs and... must be made at 23 ±3 °C. (III) Environmental tests—(1) Heat aging test—(a) Test samples. Place one... to allow one end to be accessed for test connections. Cut out a series of 6 millimeter (0.25 inch...

  1. 7 CFR 1755.890 - RUS specification for filled telephone cables with expanded insulation.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) The test procedures described in this appendix are for qualification of initial cable designs and... must be made at 23 ±3 °C. (III) Environmental tests—(1) Heat aging test—(a) Test samples. Place one... to allow one end to be accessed for test connections. Cut out a series of 6 millimeter (0.25 inch...

  2. 7 CFR 1755.890 - RUS specification for filled telephone cables with expanded insulation.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) The test procedures described in this appendix are for qualification of initial cable designs and... must be made at 23 ±3 °C. (III) Environmental tests—(1) Heat aging test—(a) Test samples. Place one... to allow one end to be accessed for test connections. Cut out a series of 6 millimeter (0.25 inch...

  3. 7 CFR 1755.890 - RUS specification for filled telephone cables with expanded insulation.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...) The test procedures described in this appendix are for qualification of initial cable designs and... must be made at 23 ±3 °C. (III) Environmental tests—(1) Heat aging test—(a) Test samples. Place one... to allow one end to be accessed for test connections. Cut out a series of 6 millimeter (0.25 inch...

  4. 7 CFR 1755.890 - RUS specification for filled telephone cables with expanded insulation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) The test procedures described in this appendix are for qualification of initial cable designs and... must be made at 23 ±3 °C. (III) Environmental tests—(1) Heat aging test—(a) Test samples. Place one... to allow one end to be accessed for test connections. Cut out a series of 6 millimeter (0.25 inch...

  5. Acquisition Handbook - Update. Comprehensive Approach to Reusable Defensive Software (CARDS)

    DTIC Science & Technology

    1994-03-25

    designs, and implementation components (source code, test plans, procedures and results, and system/software documentation). This handbook provides a...activities where software components are acquired, evaluated, tested and sometimes modified. In addition to serving as a facility for the acquisition and...systems from such components [1]. Implementation components are at the lowest level and consist of: specifications; detailed designs; code, test

  6. Validation protocol of analytical procedures for quantification of drugs in polymeric systems for parenteral administration: dexamethasone phosphate disodium microparticles.

    PubMed

    Martín-Sabroso, Cristina; Tavares-Fernandes, Daniel Filipe; Espada-García, Juan Ignacio; Torres-Suárez, Ana Isabel

    2013-12-15

    In this work a protocol to validate analytical procedures for the quantification of drug substances formulated in polymeric systems that comprise both drug entrapped into the polymeric matrix (assay:content test) and drug released from the systems (assay:dissolution test) is developed. This protocol is applied to the validation two isocratic HPLC analytical procedures for the analysis of dexamethasone phosphate disodium microparticles for parenteral administration. Preparation of authentic samples and artificially "spiked" and "unspiked" samples is described. Specificity (ability to quantify dexamethasone phosphate disodium in presence of constituents of the dissolution medium and other microparticle constituents), linearity, accuracy and precision are evaluated, in the range from 10 to 50 μg mL(-1) in the assay:content test procedure and from 0.25 to 10 μg mL(-1) in the assay:dissolution test procedure. The robustness of the analytical method to extract drug from microparticles is also assessed. The validation protocol developed allows us to conclude that both analytical methods are suitable for their intended purpose, but the lack of proportionality of the assay:dissolution analytical method should be taken into account. The validation protocol designed in this work could be applied to the validation of any analytical procedure for the quantification of drugs formulated in controlled release polymeric microparticles. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. WHO Expert Committee on Specifications for Pharmaceutical Preparations.

    PubMed

    2009-01-01

    The Expert Committee on Specifications for Pharmaceutical Preparations works towards clear, independent and practical standards and guidelines for the quality assurance of medicines. Standards are developed by the Committee through worldwide consultation and an international consensus-building process. The following new standards and guidelines were adopted and recommended for use: the current list of available International Chemical Reference Substances and International Infrared Reference Spectra; guidelines on stability testing of active pharmaceutical ingredients and finished pharmaceutical products; procedure for prequalification of pharmaceutical products; and the procedure for assessing the acceptability, in principle, of active pharmaceutical ingredients for use in pharmaceutical products.

  8. Stereotactic (Mammographically Guided) Breast Biopsy

    MedlinePlus

    ... the type of biopsy being performed or the design of the biopsy machine, a biopsy of tissue ... cost information. The costs for specific medical imaging tests, treatments and procedures may vary by geographic region. ...

  9. EPA Approved Regulations in the California SIP

    EPA Pesticide Factsheets

    EPA approved California statutes and regulations incorporated by reference in the applicable State Implementation Plan (SIP), as well as approved test procedures, methods and specifications that are cited in certain regulations listed.

  10. Verification of examination procedures in clinical laboratory for imprecision, trueness and diagnostic accuracy according to ISO 15189:2012: a pragmatic approach.

    PubMed

    Antonelli, Giorgia; Padoan, Andrea; Aita, Ada; Sciacovelli, Laura; Plebani, Mario

    2017-08-28

    Background The International Standard ISO 15189 is recognized as a valuable guide in ensuring high quality clinical laboratory services and promoting the harmonization of accreditation programmes in laboratory medicine. Examination procedures must be verified in order to guarantee that their performance characteristics are congruent with the intended scope of the test. The aim of the present study was to propose a practice model for implementing procedures employed for the verification of validated examination procedures already used for at least 2 years in our laboratory, in agreement with the ISO 15189 requirement at the Section 5.5.1.2. Methods In order to identify the operative procedure to be used, approved documents were identified, together with the definition of performance characteristics to be evaluated for the different methods; the examination procedures used in laboratory were analyzed and checked for performance specifications reported by manufacturers. Then, operative flow charts were identified to compare the laboratory performance characteristics with those declared by manufacturers. Results The choice of performance characteristics for verification was based on approved documents used as guidance, and the specific purpose tests undertaken, a consideration being made of: imprecision and trueness for quantitative methods; diagnostic accuracy for qualitative methods; imprecision together with diagnostic accuracy for semi-quantitative methods. Conclusions The described approach, balancing technological possibilities, risks and costs and assuring the compliance of the fundamental component of result accuracy, appears promising as an easily applicable and flexible procedure helping laboratories to comply with the ISO 15189 requirements.

  11. Precision of guided scanning procedures for full-arch digital impressions in vivo.

    PubMed

    Zimmermann, Moritz; Koller, Christina; Rumetsch, Moritz; Ender, Andreas; Mehl, Albert

    2017-11-01

    System-specific scanning strategies have been shown to influence the accuracy of full-arch digital impressions. Special guided scanning procedures have been implemented for specific intraoral scanning systems with special regard to the digital orthodontic workflow. The aim of this study was to evaluate the precision of guided scanning procedures compared to conventional impression techniques in vivo. Two intraoral scanning systems with implemented full-arch guided scanning procedures (Cerec Omnicam Ortho; Ormco Lythos) were included along with one conventional impression technique with irreversible hydrocolloid material (alginate). Full-arch impressions were taken three times each from 5 participants (n = 15). Impressions were then compared within the test groups using a point-to-surface distance method after best-fit model matching (OraCheck). Precision was calculated using the (90-10%)/2 quantile and statistical analysis with one-way repeated measures ANOVA and post hoc Bonferroni test was performed. The conventional impression technique with alginate showed the lowest precision for full-arch impressions with 162.2 ± 71.3 µm. Both guided scanning procedures performed statistically significantly better than the conventional impression technique (p < 0.05). Mean values for group Cerec Omnicam Ortho were 74.5 ± 39.2 µm and for group Ormco Lythos 91.4 ± 48.8 µm. The in vivo precision of guided scanning procedures exceeds conventional impression techniques with the irreversible hydrocolloid material alginate. Guided scanning procedures may be highly promising for clinical applications, especially for digital orthodontic workflows.

  12. Standard Procedures for Air Force Operational Test and Evaluation. Volume I. Appendices

    DTIC Science & Technology

    1974-10-01

    Participates in selected tests data for assessment of suitability Participates in the intepretation of and effectiveness, as practicable tet results...selected tests Interprels test results Inteprets test resultst ReplRorts to CNO the results of the "eports independent operational TI’ECIIEVAL assessment" v... films , lists, tapes, drawings, specifications. parts breakdowns, ctc. RAW DATA; ’The original form of data at the time it was recorded. DATA

  13. Treatment of RDX and/or HMX Using Mulch Biowalls

    DTIC Science & Technology

    2008-04-01

    industrial classification TAL target analyte list TCE trichloroethene TCLP toxicity characteristic leachate procedure TNB 1,3,5-Trinitobenzene TNT... leachate procedure (TCLP) testing results for the mulch fill in the site-specific treatability phase confirmed no leaching of the target...0.01% 1 ɘ.001% 0.1% * i. Presence of other remediation technologies in the immediate vicinity No 4 No Yes, active phytoremediation in Pink Water

  14. Reveal Listeria 2.0 test for detection of Listeria spp. in foods and environmental samples.

    PubMed

    Alles, Susan; Curry, Stephanie; Almy, David; Jagadeesan, Balamurugan; Rice, Jennifer; Mozola, Mark

    2012-01-01

    A Performance Tested Method validation study was conducted for a new lateral flow immunoassay (Reveal Listeria 2.0) for detection of Listeria spp. in foods and environmental samples. Results of inclusivity testing showed that the test detects all species of Listeria, with the exception of L. grayi. In exclusivity testing conducted under nonselective growth conditions, all non-listeriae tested produced negative Reveal assay results, except for three strains of Lactobacillus spp. However, these lactobacilli are inhibited by the selective Listeria Enrichment Single Step broth enrichment medium used with the Reveal method. Six foods were tested in parallel by the Reveal method and the U.S. Food and Drug Administration/Bacteriological Analytical Manual (FDA/BAM) reference culture procedure. Considering data from both internal and independent laboratory trials, overall sensitivity of the Reveal method relative to that of the FDA/BAM procedure was 101%. Four foods were tested in parallel by the Reveal method and the U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) reference culture procedure. Overall sensitivity of the Reveal method relative to that of the USDA-FSIS procedure was 98.2%. There were no statistically significant differences in the number of positives obtained by the Reveal and reference culture procedures in any food trials. In testing of swab or sponge samples from four types of environmental surfaces, sensitivity of Reveal relative to that of the USDA-FSIS reference culture procedure was 127%. For two surface types, differences in the number of positives obtained by the Reveal and reference methods were statistically significant, with more positives by the Reveal method in both cases. Specificity of the Reveal assay was 100%, as there were no unconfirmed positive results obtained in any phase of the testing. Results of ruggedness experiments showed that the Reveal assay is tolerant of modest deviations in test sample volume and device incubation time.

  15. Design, fabrication and testing of porous tungsten vaporizers for mercury ion thrusters

    NASA Technical Reports Server (NTRS)

    Zavesky, R.; Kroeger, E.; Kami, S.

    1983-01-01

    The dispersions in the characteristics, performance and reliability of vaporizers for early model 30-cm thrusters were investigated. The purpose of the paper is to explore the findings and to discuss the approaches that were taken to reduce the observed dispersion and present the results of a program which validated those approaches. The information that is presented includes porous tungsten materials specifications, a discussion of assembly procedures, and a description of a test program which screens both material and fabrication processes. There are five appendices providing additional detail in the areas of vaporizer contamination, nitrogen flow testing, bubble testing, porosimeter testing, and mercury purity. Four neutralizers, seven cathodes and five main vaporizers were successfully fabricated, tested, and operated on thrusters. Performance data from those devices is presented and indicates extremely repeatable results from using the design and fabrication procedures.

  16. French consensus procedure for assessing cognitive function in Parkinson's disease.

    PubMed

    Dujardin, K; Auzou, N; Lhommée, E; Czernecki, V; Dubois, B; Fradet, A; Maltete, D; Meyer, M; Pineau, F; Schmitt, E; Sellal, F; Tison, F; Vidal, T; Azulay, J-P; Welter, M-L; Corvol, J-C; Durif, F; Rascol, O

    2016-11-01

    One of the objectives of the French expert centers for Parkinson's disease (NS-Park) network was to determine a consensus procedure for assessing cognitive function in patients with Parkinson's. This article presents this procedure and briefly describes the selected tests. A group of 13 experts used the Delphi method for consensus building to define the overall structure and components of the assessment procedure. For inclusion in the battery, tests had to be validated in the French language, require little motor participation, have normative data and be recognized by the international community. Experimental tasks and tests requiring specific devices were excluded. Two possibilities were identified, depending on whether an abbreviated or comprehensive assessment of cognitive function was necessary. For an abbreviated assessment, the experts recommended the Montreal Cognitive Assessment (MoCA) as a screening test for cognitive impairment or dementia. For a comprehensive neuropsychological assessment, the experts recommended assessing global efficiency plus the five main cognitive domains (attention and working memory, executive function, episodic memory, visuospatial function and language) that may be impaired in Parkinson's disease, using two tests for each domain. A common procedure for assessing cognitive function is now available across the French network dedicated to Parkinson's disease, and is recommended for both research and clinical practice. It will also help to promote standardization of the neuropsychological assessment of Parkinson's disease. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  17. Magnetic Resonance (MR)-Guided Breast Biopsy

    MedlinePlus

    ... the type of biopsy being performed or the design of the biopsy machine, a biopsy of tissue ... cost information. The costs for specific medical imaging tests, treatments and procedures may vary by geographic region. ...

  18. The future (r)evolution of preimplantation genetic diagnosis/human leukocyte antigen testing: ethical reflections.

    PubMed

    de Wert, Guido; Liebaers, Inge; Van de Velde, Hilde

    2007-09-01

    There has been increasing support for combining preimplantation genetic diagnosis (PGD) for specific diseases with a test for human leukocyte antigens (HLA) because the generation of HLA-matched umbilical cord blood cells may save the life of a diseased sibling. To date, this procedure has taken place in the context of conceiving another child--PGD/HLA testing type 1. However, it may well become possible to perform PGD/HLA testing outside this context, that is, to select matched embryos from which embryonic stem cells could be derived and used in cell therapy--PGD/HLA testing type 2. A proactive ethical analysis is needed and is presented in this article. Although PGD/HLA testing type 1 can be morally justified, the risks, pitfalls, and practical limitations of this procedure make it necessary to develop alternative strategies. PGD/HLA testing type 2 may provide an alternative strategy. From an ethical point of view, the controversial issue is that this procedure creates embryos purely for instrumental use. However, given the dominant view that the preimplantation embryo has only limited moral value, this alternative may be as morally justified as PGD/HLA testing type 1.

  19. On the efficacy of procedures to normalize Ex-Gaussian distributions.

    PubMed

    Marmolejo-Ramos, Fernando; Cousineau, Denis; Benites, Luis; Maehara, Rocío

    2014-01-01

    Reaction time (RT) is one of the most common types of measure used in experimental psychology. Its distribution is not normal (Gaussian) but resembles a convolution of normal and exponential distributions (Ex-Gaussian). One of the major assumptions in parametric tests (such as ANOVAs) is that variables are normally distributed. Hence, it is acknowledged by many that the normality assumption is not met. This paper presents different procedures to normalize data sampled from an Ex-Gaussian distribution in such a way that they are suitable for parametric tests based on the normality assumption. Using simulation studies, various outlier elimination and transformation procedures were tested against the level of normality they provide. The results suggest that the transformation methods are better than elimination methods in normalizing positively skewed data and the more skewed the distribution then the transformation methods are more effective in normalizing such data. Specifically, transformation with parameter lambda -1 leads to the best results.

  20. Development of a High Accuracy Angular Measurement System for Langley Research Center Hypersonic Wind Tunnel Facilities

    NASA Technical Reports Server (NTRS)

    Newman, Brett; Yu, Si-bok; Rhew, Ray D. (Technical Monitor)

    2003-01-01

    Modern experimental and test activities demand innovative and adaptable procedures to maximize data content and quality while working within severely constrained budgetary and facility resource environments. This report describes development of a high accuracy angular measurement capability for NASA Langley Research Center hypersonic wind tunnel facilities to overcome these deficiencies. Specifically, utilization of micro-electro-mechanical sensors including accelerometers and gyros, coupled with software driven data acquisition hardware, integrated within a prototype measurement system, is considered. Development methodology addresses basic design requirements formulated from wind tunnel facility constraints and current operating procedures, as well as engineering and scientific test objectives. Description of the analytical framework governing relationships between time dependent multi-axis acceleration and angular rate sensor data and the desired three dimensional Eulerian angular state of the test model is given. Calibration procedures for identifying and estimating critical parameters in the sensor hardware is also addressed.

  1. Chewability testing in the development of a chewable tablet for hyperphosphatemia.

    PubMed

    Lanz, Michael; Baldischweiler, Jan; Kriwet, Burkhard; Schill, Jutta; Stafford, John; Imanidis, Georgios

    2014-12-01

    The official Pharmacopeia does not include a test procedure for the in vitro estimation of the chewability of tablets and publications in the scientific literature on this subject are rare. The purpose of this study was to evaluate a number of different test procedures for assessing chewability, starting from standard breaking force and strength testing and progressing to develop new procedures that simulate the actual chewing action on tablets. A further goal was to apply these test procedures to characterize the chewability of the novel phosphate binder PA21 in comparison with a commercially available phosphate binder chewable tablet product based on lanthanum (Fosrenol®) and a chewable tablet product containing calcium (Calcimagon®) - the latter being used as a standard for its very good chewability. For this purpose, a number of development formulations (different batches of PA21) were tested. The radial or diametrical tablet breaking force offers a poor means of assessing chewability while the axial breaking force was concluded to better reflect the effect of chewing on the tablet. Measurement of tablet behavior upon repeated loading afforded the best simulation of the actual chewing action and was found to have a good discriminating power with respect to chewability of the tested tablets, especially when the tablet was moistened with artificial saliva. The developed tests are shown to be more suitable for evaluating chewing properties of tablets than currently used Pharmacopeial tests. Following ICHQ6, which calls for specification of hardness for chewable tablets, these test procedures enabled the optimal chewability features of PA21 tablets in development to be confirmed whilst still maintaining capabilities for robust production and transportation processes.

  2. Efficacy Outcome Measures for Procedural Sedation Clinical Trials in Adults: An ACTTION Systematic Review.

    PubMed

    Williams, Mark R; McKeown, Andrew; Dexter, Franklin; Miner, James R; Sessler, Daniel I; Vargo, John; Turk, Dennis C; Dworkin, Robert H

    2016-01-01

    Successful procedural sedation represents a spectrum of patient- and clinician-related goals. The absence of a gold-standard measure of the efficacy of procedural sedation has led to a variety of outcomes being used in clinical trials, with the consequent lack of consistency among measures, making comparisons among trials and meta-analyses challenging. We evaluated which existing measures have undergone psychometric analysis in a procedural sedation setting and whether the validity of any of these measures support their use across the range of procedures for which sedation is indicated. Numerous measures were found to have been used in clinical research on procedural sedation across a wide range of procedures. However, reliability and validity have been evaluated for only a limited number of sedation scales, observer-rated pain/discomfort scales, and satisfaction measures in only a few categories of procedures. Typically, studies only examined 1 or 2 aspects of scale validity. The results are likely unique to the specific clinical settings they were tested in. Certain scales, for example, those requiring motor stimulation, are unsuitable to evaluate sedation for procedures where movement is prohibited (e.g., magnetic resonance imaging scans). Further work is required to evaluate existing measures for procedures for which they were not developed. Depending on the outcomes of these efforts, it might ultimately be necessary to consider measures of sedation efficacy to be procedure specific.

  3. 78 FR 7939 - Energy Conservation Program: Test Procedures for Microwave Ovens (Active Mode)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-04

    ...The U.S. Department of Energy (DOE) proposes to revise its test procedures for microwave ovens established under the Energy Policy and Conservation Act. The proposed amendments would add provisions for measuring the active mode energy use for microwave ovens, including both microwave-only ovens and convection microwave ovens. Specifically, DOE is proposing provisions for measuring the energy use of the microwave-only cooking mode for both microwave-only ovens and convection microwave ovens based on the testing methods in the latest draft version of the International Electrotechnical Commission Standard 60705, ``Household microwave ovens--Methods for measuring performance.'' DOE is proposing provisions for measuring the energy use of the convection-only cooking mode for convection microwave ovens based on the DOE test procedure for conventional ovens in our regulations. DOE is also proposing to calculate the energy use of the convection-microwave cooking mode for convection microwave ovens by apportioning the microwave-only mode and convection-only mode energy consumption measurements based on typical consumer use.

  4. Guidelines for Standardized Testing of Broadband Seismometers and Accelerometers

    USGS Publications Warehouse

    Hutt, Charles R.; Evans, John R.; Followill, Fred; Nigbor, Robert L.; Wielandt, Erhard

    2010-01-01

    Testing and specification of seismic and earthquake-engineering sensors and recorders has been marked by significant variations in procedures and selected parameters. These variations cause difficulty in comparing such specifications and test results. In July 1989, and again in May 2005, the U.S. Geological Survey hosted international pub-lic/private workshops with the goal of defining widely accepted guidelines for the testing of seismological inertial sensors, seismometers, and accelerometers. The Proceedings of the 2005 workshop have been published and include as appendix 6 the report of the 1989 workshop. This document represents a collation and rationalization of a single set of formal guidelines for testing and specifying broadband seismometers and accelerometers.

  5. Measuring Literary Reading Motivation: Questionnaires Design and Pilot Testing

    ERIC Educational Resources Information Center

    Chrysos, Michail

    2017-01-01

    This study aims to present the design and pilot testing procedures of the two specific self-report questionnaires were used to measure the two key aspects of reading motivation, self-efficacy and intrinsic motivation in the field of literary (narrative) reading, and the partial factors that jointly shape them. These instruments were outlined in…

  6. Diagnosing Trouble Spots Caused by an Irrigation System

    Treesearch

    John R. Scholtes

    2002-01-01

    I discuss a testing procedure to determine the water distribution pattern of a sprinkler irrigation system and steps that may be taken to improve uniformity of application. All irrigation systems require testing and maintenance to assure that water application is as uniform as possible. Even new systems installed to a manufacturer's specifications should be "...

  7. Developing and Validating a Rapid Small-Scale Column Test Procedure for GAC Selection using Reconstituted Lyophilized NOM

    EPA Science Inventory

    Cost effective design and operation of Granular Activated Carbon (GAC) facilities requires the selection of GAC that is optimal for a specific site. Rapid small-scale column tests (RSSCTs) are widely used for GAC assessment due to several advantages, including the ability to simu...

  8. Motivation Filtering on a Multi-Institution Assessment of General College Outcomes

    ERIC Educational Resources Information Center

    Steedle, Jeffrey T.

    2014-01-01

    Possible lack of motivation is a perpetual concern when tests have no stakes attached to performance. Specifically, the validity of test score interpretations may be compromised when examinees are unmotivated to exert their best efforts. Motivation filtering, a procedure that filters out apparently unmotivated examinees, was applied to the…

  9. Optical fibers for FTTH application

    NASA Astrophysics Data System (ADS)

    Guzowski, Bartlomiej; Tosik, Grzegorz; Lisik, Zbigniew; Bedyk, Michal; Kubiak, Andrzej

    2013-07-01

    In this paper the specifics of FTTH (Fiber To The Home) networks in terms of requirements for optical fibers has been presented. Optical fiber samples used in FTTH applications acquired from the worldwide leading manufacturers were subjected to small diameter mandrel wraps tests. The detailed procedures of performed tests and the measurement results has been presented.

  10. Developing and Validating a Rapid Small-Scale Column Test Procedure for GAC Selection using Reconstituted Lyophilized NOM - Portland, OR

    EPA Science Inventory

    Cost effective design and operation of Granular Activated Carbon (GAC) facilities requires the selection of GAC that is optimal for a specific site. Rapid small-scale column tests (RSSCTs) are widely used for GAC assessment due to several advantages, including the ability to simu...

  11. Recommended procedures for measuring aircraft noise and associated parameters

    NASA Technical Reports Server (NTRS)

    Marsh, A. H.

    1977-01-01

    Procedures are recommended for obtaining experimental values of aircraft flyover noise levels (and associated parameters). Specific recommendations are made for test criteria, instrumentation performance requirements, data-acquisition procedures, and test operations. The recommendations are based on state-of-the-art measurement capabilities available in 1976 and are consistent with the measurement objectives of the NASA Aircraft Noise Prediction Program. The recommendations are applicable to measurements of the noise produced by an airplane flying subsonically over (or past) microphones located near the surface of the ground. Aircraft types covered by the recommendations are fixed-wing airplanes powered by turbojet or turbofan engines and using conventional aerodynamic means for takeoff and landing. Various assumptions with respect to subsequent data processing and analysis were made (and are described) and the recommended measurement procedures are compatible with the assumptions. Some areas where additional research is needed relative to aircraft flyover noise measurement techniques are also discussed.

  12. Evaluation of the Storm 3 data logger manufactured by WaterLOG/Xylem Incorporated—Results of bench, temperature, and field deployment testing

    USGS Publications Warehouse

    Kunkle, Gerald A.

    2016-05-04

    The procedures followed and the results obtained from the testing are described in this publication. The device met most of the manufacturer’s stated specifications. An exception was power consumption, which was about 10 percent above the manufacturer’s specifications. It was also observed that enabling WiFi doubles the Storm 3’s power consumption. In addition, several logging errors were made by two units during deployment testing, but it could not be determined whether these errors were the fault of the Storm or of an attached sensor.

  13. Multiple statistical tests: Lessons from a d20.

    PubMed

    Madan, Christopher R

    2016-01-01

    Statistical analyses are often conducted with α= .05. When multiple statistical tests are conducted, this procedure needs to be adjusted to compensate for the otherwise inflated Type I error. In some instances in tabletop gaming, sometimes it is desired to roll a 20-sided die (or 'd20') twice and take the greater outcome. Here I draw from probability theory and the case of a d20, where the probability of obtaining any specific outcome is (1)/ 20, to determine the probability of obtaining a specific outcome (Type-I error) at least once across repeated, independent statistical tests.

  14. Checkout and Standard Use Procedures for the Mark III Space Suit Assembly

    NASA Technical Reports Server (NTRS)

    Valish, Dana J.

    2012-01-01

    The operational pressure range is the range to which the suit can be nominally operated for manned testing. The top end of the nominal operational pressure range is equivalent to 1/2 the proof pressure. Structural pressure is 1.5 times the specified test pressure for any given test. Proof pressure is the maximum unmanned pressure to which the suit was tested by the vendor prior to delivery. The maximum allowable working pressure (MAWP) is 90% of the proof pressure. The pressure systems RVs are set to keep components below their MAWPs. If the suit is pressurized over its MAWP, the suit will be taken out of service and an in-depth inspection/review of the suit will be performed before the suit is put back in service. The procedures outlined in this document should be followed as written. However, the suit test engineer (STE) may make redline changes real-time, provided those changes are recorded in the anomaly section of the test data sheet. If technicians supporting suit build-up, check-out, and/or test execution believe that a procedure can be improved, they should notify their lead. If procedures are incorrect to the point of potentially causing hardware damage or affecting safety, bring the problem to the technician lead and/or STE s attention and stop work until a solution (temporary or permanent) is authorized. Certain steps in the procedure are marked with a DV , for Designated Verifier. The Designated Verifier for this procedure is an Advanced Space Suit Technology Development Laboratory technician, not directly involved in performing the procedural steps, who will verify that the step was performed as stated. The steps to be verified by the DV were selected based on one or more of the following criteria: the step was deemed significant in ensuring the safe performance of the test, the data recorded in the step is of specific interest in monitoring the suit system operation, or the step has a strong influence on the successful completion of test objectives. Prior to all manned test activities, Advanced Suit Test Data Sheet (TDS) Parts A-E shall be completed to verify system and team are ready for test. Advanced Suit TDS Parts F-G shall be completed at the end of the suited activity. Appendix B identifies tha appropriate Mark III suit emergency event procedures.

  15. Specific NIST projects in support of the NIJ Concealed Weapon Detection and Imaging Program

    NASA Astrophysics Data System (ADS)

    Paulter, Nicholas G.

    1998-12-01

    The Electricity Division of the National Institute of Standards and Technology is developing revised performance standards for hand-held (HH) and walk-through (WT) metal weapon detectors, test procedures and systems for these detectors, and a detection/imaging system for finding concealed weapons. The revised standards will replace the existing National Institute of Justice (NIJ) standards for HH and WT devices and will include detection performance specifications as well as system specifications (environmental conditions, mechanical strength and safety, response reproducibility and repeatability, quality assurance, test reporting, etc.). These system requirements were obtained from the Law Enforcement and corrections Technology Advisory Council, an advisory council for the NIJ. Reproducible and repeatable test procedures and appropriate measurement systems will be developed for evaluating HH and WT detection performance. A guide to the technology and application of non- eddy-current-based detection/imaging methods (such as acoustic, passive millimeter-wave and microwave, active millimeter-wave and terahertz-wave, x-ray, etc.) Will be developed. The Electricity Division is also researching the development of a high- frequency/high-speed (300 GH to 1 THz) pulse-illuminated, stand- off, video-rate, concealed weapons/contraband imaging system.

  16. Welding procedure specification. Suppliment 1. Records of procedure qualification tests. Gas tungsten arc welding of aluminum alloys 1XXX and 3003 to 3004, 5052 and 5X54. [1060, 1100, and 3003 to 3004, 5052, 5154, and 5454

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wodtke, C.H.; Frizzell, D.R.; Plunkett, W.A.

    1986-06-01

    Procedure WPS-2202 is qualified under Section IX of the ASME Boiler and Pressure Vessel Code for gas tungsten arc welding of aluminum alloys 1060, 1100, and 3003 (P-21) to 3004, 5052, 5154, and 5454 (P-22), in thickness range 0.062 to 0.062 to 0.5 inch; filler metal is ER5356 (F-22); shielding gas is argon.

  17. Effect of airway clearance techniques on the efficacy of the sputum induction procedure.

    PubMed

    Elkins, M R; Lane, T; Goldberg, H; Pagliuso, J; Garske, L A; Hector, E; Marchetto, L; Alison, J A; Bye, P T P

    2005-11-01

    Sputum induction is used in the early identification of tuberculosis (TB) and pneumocystis infections of the lung. Although manual physiotherapy techniques to clear the airways are often incorporated in the sputum induction procedure, their efficacy in this setting is unknown. This randomised, crossover trial enrolled adults referred for sputum induction for suspected TB and pneumocystis infections of the lung. All participants underwent two sputum induction procedures, inhaling 3% saline via ultrasonic nebuliser. During one randomly allocated procedure, airway clearance techniques (chest wall percussion, vibration, huffing) were incorporated. In total, 59 participants completed the trial. The airway clearance techniques had no significant effect on how the test was tolerated, the volume expectorated or the quality of the sample obtained (assessed by the presence of alveolar macrophages). The techniques did not significantly affect how often the test identified a suspected organism, nor the sensitivity or specificity of sputum induction. In conclusion, the study was unable to demonstrate any effect of airway clearance techniques on the sputum induction procedure. The results provide some justification for not including airway clearance techniques as part of the sputum induction procedure.

  18. High Voltage Testing. Volume 2. Specifications and Test Procedures

    DTIC Science & Technology

    1982-08-01

    the greatest impact on the initial assumption and criteria developed in the published criteria documents include: dielectric withstanding voltage...3382-75 Measurement of Energy and Integrated Charge Transfer Due to Partial Discharges (Corona) Using Bridge Techniques. ASTM-D 3426 - Dielectric... Energy (NEMA Publication No. WC 7-1971). NEMA Publication No. 109 - AIEE-EEI-NEMA Standard Basic Insulation Level. 092-57 - Method of Test for Flash and

  19. 40 CFR 600.114-08 - Vehicle-specific 5-cycle fuel economy and carbon-related exhaust emission calculations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Vehicle-specific 5-cycle fuel economy... Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND GREENHOUSE GAS EXHAUST EMISSIONS OF MOTOR VEHICLES Fuel Economy and Carbon-Related Exhaust Emission Test Procedures § 600.114-08...

  20. 40 CFR 600.114-12 - Vehicle-specific 5-cycle fuel economy and carbon-related exhaust emission calculations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Vehicle-specific 5-cycle fuel economy... Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND GREENHOUSE GAS EXHAUST EMISSIONS OF MOTOR VEHICLES Fuel Economy and Carbon-Related Exhaust Emission Test Procedures § 600.114-12...

  1. 40 CFR 600.114-12 - Vehicle-specific 5-cycle fuel economy and carbon-related exhaust emission calculations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Vehicle-specific 5-cycle fuel economy... Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND GREENHOUSE GAS EXHAUST EMISSIONS OF MOTOR VEHICLES Fuel Economy and Carbon-Related Exhaust Emission Test Procedures § 600.114-12...

  2. 40 CFR 600.114-08 - Vehicle-specific 5-cycle fuel economy and carbon-related exhaust emission calculations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Vehicle-specific 5-cycle fuel economy... Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND GREENHOUSE GAS EXHAUST EMISSIONS OF MOTOR VEHICLES Fuel Economy and Carbon-Related Exhaust Emission Test Procedures § 600.114-08...

  3. Development and utilization of extracorporeal regional complexing hemodialysis as a means of mobilizing and enhancing the excretion of methylmercury in the dog. [N-acetylcysteine; N-acetylpenicillamine; 2,3-dimercaptosuccinic acid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kostyniak, P.J.

    1975-01-01

    The present investigation was directed at developing and testing a new procedure for increasing methylmercury excretion in the dog. The procedure utilizes hemodialysis in conjunction with the extracorporeal reversal of protein binding of methylmercury in blood by the presence of low molecular weight sulfhydryl containing complexing agents (cysteine, N-acetylcysteine, penicillamine, N-acetylpenicillamine, 2,3-dimercaptosuccinic acid) having a high chemical affinity for methylmercury. Using such a procedure, the complexed methylmercury and the free complexing agent were found to be readily removed from blood by the dialyzer. Unlike chelation therapy, this procedure does not rely on the attainment of high systemic concentrations of complexingmore » agent in order to attain enhanced excretion by normal routes. It rather introduces into the circulatory system a shunt designed specifically for methylmercury extraction from blood. In vitro testing of this procedure revealed that methylmercury removal from blood was dependent upon the concentration of complexing agent in blood and the dialyzer blood flow rate. In vivo testing of the procedure in the dog utilized a standard hemodialyzer with infusion of complexing agent into the arterial dialyzer blood line. The rate of methylmercury removal from the dog during the treatment procedures were as high as 400 times the excretion rate of mercury in untreated dogs.« less

  4. 40 CFR 1066.20 - Units of measure and overview of calculations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Applicability and General Provisions § 1066.20 Units of..., repeatability, linearity, or noise specification. See 40 CFR 1065.1001 for the definition of tolerance. In this...

  5. 17 CFR Appendix A to Part 38 - Guidance on Compliance With Designation Criteria

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...-matching algorithm and order entry procedures. An application involving a trade-matching algorithm that is... algorithm. (b) A designated contract market's specifications on initial and periodic objective testing and...

  6. 17 CFR Appendix A to Part 38 - Guidance on Compliance With Designation Criteria

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...-matching algorithm and order entry procedures. An application involving a trade-matching algorithm that is... algorithm. (b) A designated contract market's specifications on initial and periodic objective testing and...

  7. Working, declarative and procedural memory in specific language impairment

    PubMed Central

    Lum, Jarrad A.G.; Conti-Ramsden, Gina; Page, Debra; Ullman, Michael T.

    2012-01-01

    According to the Procedural Deficit Hypothesis (PDH), abnormalities of brain structures underlying procedural memory largely explain the language deficits in children with specific language impairment (SLI). These abnormalities are posited to result in core deficits of procedural memory, which in turn explain the grammar problems in the disorder. The abnormalities are also likely to lead to problems with other, non-procedural functions, such as working memory, that rely at least partly on the affected brain structures. In contrast, declarative memory is expected to remain largely intact, and should play an important compensatory role for grammar. These claims were tested by examining measures of working, declarative and procedural memory in 51 children with SLI and 51 matched typically-developing (TD) children (mean age 10). Working memory was assessed with the Working Memory Test Battery for Children, declarative memory with the Children’s Memory Scale, and procedural memory with a visuo-spatial Serial Reaction Time task. As compared to the TD children, the children with SLI were impaired at procedural memory, even when holding working memory constant. In contrast, they were spared at declarative memory for visual information, and at declarative memory in the verbal domain after controlling for working memory and language. Visuo-spatial short-term memory was intact, whereas verbal working memory was impaired, even when language deficits were held constant. Correlation analyses showed neither visuo-spatial nor verbal working memory was associated with either lexical or grammatical abilities in either the SLI or TD children. Declarative memory correlated with lexical abilities in both groups of children. Finally, grammatical abilities were associated with procedural memory in the TD children, but with declarative memory in the children with SLI. These findings replicate and extend previous studies of working, declarative and procedural memory in SLI. Overall, we suggest that the evidence largely supports the predictions of the PDH. PMID:21774923

  8. Methods for detection, identification and specification of listerias

    DOEpatents

    Bochner, Barry

    1992-01-01

    The present invention relates generally to differential carbon source metabolism in the genus Listeria, metabolic, biochemical, immunological and genetic procedures to measure said differential carbon source metabolism and the use of these produces to detect, isolate and/or distinguish species of the genus Listeria as well as detect, isolate and/or distinguish strains of species of Listeria. The present invention also contemplates test kits and enrichment media to facilitate these procedures.

  9. Detecting temporal trends in species assemblages with bootstrapping procedures and hierarchical models

    USGS Publications Warehouse

    Gotelli, Nicholas J.; Dorazio, Robert M.; Ellison, Aaron M.; Grossman, Gary D.

    2010-01-01

    Quantifying patterns of temporal trends in species assemblages is an important analytical challenge in community ecology. We describe methods of analysis that can be applied to a matrix of counts of individuals that is organized by species (rows) and time-ordered sampling periods (columns). We first developed a bootstrapping procedure to test the null hypothesis of random sampling from a stationary species abundance distribution with temporally varying sampling probabilities. This procedure can be modified to account for undetected species. We next developed a hierarchical model to estimate species-specific trends in abundance while accounting for species-specific probabilities of detection. We analysed two long-term datasets on stream fishes and grassland insects to demonstrate these methods. For both assemblages, the bootstrap test indicated that temporal trends in abundance were more heterogeneous than expected under the null model. We used the hierarchical model to estimate trends in abundance and identified sets of species in each assemblage that were steadily increasing, decreasing or remaining constant in abundance over more than a decade of standardized annual surveys. Our methods of analysis are broadly applicable to other ecological datasets, and they represent an advance over most existing procedures, which do not incorporate effects of incomplete sampling and imperfect detection.

  10. Using expert knowledge for test linking.

    PubMed

    Bolsinova, Maria; Hoijtink, Herbert; Vermeulen, Jorine Adinda; Béguin, Anton

    2017-12-01

    Linking and equating procedures are used to make the results of different test forms comparable. In the cases where no assumption of random equivalent groups can be made some form of linking design is used. In practice the amount of data available to link the two tests is often very limited due to logistic and security reasons, which affects the precision of linking procedures. This study proposes to enhance the quality of linking procedures based on sparse data by using Bayesian methods which combine the information in the linking data with background information captured in informative prior distributions. We propose two methods for the elicitation of prior knowledge about the difference in difficulty of two tests from subject-matter experts and explain how these results can be used in the specification of priors. To illustrate the proposed methods and evaluate the quality of linking with and without informative priors, an empirical example of linking primary school mathematics tests is presented. The results suggest that informative priors can increase the precision of linking without decreasing the accuracy. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  11. Preliminary vibration, acoustic, and shock design and test criteria for components on the SRB, ET, and SSME

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Specifications for vibration, acoustic and shock design for components and subassemblies on the External Tank (ET), Solid Rocket Booster (SRB), and Space Shuttle Main Engine (SSME). Included are vibration, acoustic, shock, transportation, handling, and acceptance test requirements and procedures. The space shuttle ET, SRB, and SSME have been divided into zones and subzones. Zones are designated primarily to assist in determining the applicable specifications. A subzone (General Specification) is available for use when the location of the component is known but component design and weight are not well defined. When the location, weight, and mounting configuration of the component are known, specifications for appropriate subzone weight ranges are available. Criteria for some specific components are also presented.

  12. A meta-analysis of the diagnostic test accuracy of MRA and MRI for the detection of glenoid labral injury.

    PubMed

    Smith, Toby O; Drew, Benjamin T; Toms, Andoni P

    2012-07-01

    Magnetic resonance imaging (MRI) and magnetic resonance arthrography (MRA) have gained increasing favour in the assessment of patients with suspected glenoid labral injuries. The purpose of this study was to determine the diagnostic accuracy of MRI or MRA in the detection of gleniod labral lesions. A systematic review was undertaken of the electronic databases Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, AMED and CINAHL, in addition to a search of unpublished literature databases. All studies which compared the ability of MRI or MRA (index test) to assess gleniod labral tears or lesions, when verified with a surgical procedure (arthroscopy or open surgery-reference test) were included. Data extraction and methodological appraisal using the QUADAS tool were both conducted by two reviewers independently. Data were analysed through a summary receiver operator characteristic curve and pooled sensitivity and specificity analysis were calculated with 95% confidence intervals. Sixty studies including 4,667 shoulders from 4,574 patients were reviewed. There appeared slightly greater diagnostic test accuracy for MRA over MRI for the detection of overall gleniod labral lesions (MRA-sensitivity 88%, specificity 93% vs. MRI sensitivity 76% vs. specificity 87%). Methodologically, studies recruited and identified their samples appropriately and clearly defined the radiological procedures. In general, it was not clearly defined why patients were lost during the study, and studies were poor at recording whether the same clinical data were available to the radiologist interpreting the MRI or MRA as would be available in clinical practice. Most studies did not state whether the surgeon interpreting the arthroscopic procedure was blinded to the results of the MR or MRA imaging. Based on the available literature, overall MRA appeared marginally superior to MRI for the detection of glenohumeral labral lesions. Level 2a.

  13. Manned remote work station development article. Volume 3: Development test plan. Appendix A: Manufacturing requirements/schedule

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The tests and procedures for the manned remote work station (MRWS) open cherry picker (OCP) development test article (DTA) are described to validate systems requirements and performance specifications. A development test program is outlined to evaluate key design issues and man/machine interfaces when the MRWS OCP is used in a shuttle support role of satellite servicing and in orbit construction of large structures.

  14. Pain facilitation and pain inhibition during conditioned pain modulation in fibromyalgia and in healthy controls.

    PubMed

    Potvin, Stéphane; Marchand, Serge

    2016-08-01

    Although fibromyalgia (FM) is associated with a deficit in inhibitory conditioned pain modulation (CPM), the discriminative power of CPM procedures is unknown. Moreover, the high intersubject heterogeneity in CPM responses in FM raises the possibility that a sizeable subgroup of these patients may experience pain facilitation during CPM, but the phenomenon has not been explicitly studied. To address these issues, 96 patients with FM and 71 healthy controls were recruited. Thermal stimuli were used to measure pain thresholds. Pain inhibition was elicited using a tonic thermal test (Peltier thermode) administered before and after activation of CPM mechanisms using a cold pressor test. Thermal pain thresholds were lower in patients with FM than in healthy controls. Pain ratings during the cold pressor test were higher in patients with FM, relative to controls. The CPM inhibitory efficacy was lower in patients with FM than in controls. The CPM procedure had good specificity (78.9%) but low sensitivity (45.7%), whereas a composite pain index had good sensitivity (75.0%) and specificity (78.9%). Finally, the rate of patients with FM who reported pain facilitation during the CPM procedure was found to be significantly increased compared with that of controls (41.7% vs 21.2%). The good discriminative power of the composite pain index highlights the need for further validation studies using mechanistically relevant psychophysical procedures in FM. The low sensitivity of the CPM procedure, combined with the large proportion of patients with FM experiencing pain facilitation during CPM, strongly suggests that endogenous pain inhibition mechanisms are deeply impaired in patients with FM, but only in a subgroup of them.

  15. Fluorescence In Situ Hybridization Probe Validation for Clinical Use.

    PubMed

    Gu, Jun; Smith, Janice L; Dowling, Patricia K

    2017-01-01

    In this chapter, we provide a systematic overview of the published guidelines and validation procedures for fluorescence in situ hybridization (FISH) probes for clinical diagnostic use. FISH probes-which are classified as molecular probes or analyte-specific reagents (ASRs)-have been extensively used in vitro for both clinical diagnosis and research. Most commercially available FISH probes in the United States are strictly regulated by the U.S. Food and Drug Administration (FDA), the Centers for Disease Control and Prevention (CDC), the Centers for Medicare & Medicaid Services (CMS) the Clinical Laboratory Improvement Amendments (CLIA), and the College of American Pathologists (CAP). Although home-brewed FISH probes-defined as probes made in-house or acquired from a source that does not supply them to other laboratories-are not regulated by these agencies, they too must undergo the same individual validation process prior to clinical use as their commercial counterparts. Validation of a FISH probe involves initial validation and ongoing verification of the test system. Initial validation includes assessment of a probe's technical specifications, establishment of its standard operational procedure (SOP), determination of its clinical sensitivity and specificity, development of its cutoff, baseline, and normal reference ranges, gathering of analytics, confirmation of its applicability to a specific research or clinical setting, testing of samples with or without the abnormalities that the probe is meant to detect, staff training, and report building. Ongoing verification of the test system involves testing additional normal and abnormal samples using the same method employed during the initial validation of the probe.

  16. HLA-typing analysis following allogeneic bone grafting for sinus lifting.

    PubMed

    Piaia, Marcelo; Bub, Carolina Bonet; Succi, Guilherme de Menezes; Torres, Margareth; Costa, Thiago Henrique; Pinheiro, Fabricio Costa; Napimoga, Marcelo Henrique

    2017-03-01

    According to the Brazilian Association of Organ Transplants, in 2015, 19,408 bone transplants were performed in Brazil, over 90% by Dental Surgeons. The surgical technique itself has a respectable number of reports regarding its clinical efficacy, as measured by long-term survival of dental implants in grafted areas. Uncertainty remains, however, as to whether fresh frozen grafts from human bone donors remain immunologically innocuous in the body of the host. Six male with no previous medical history of note, including systemic diseases, surgery or blood transfusion were selected. These patients underwent reconstructive procedures (sinus lifting) using fresh frozen human bone from a tissue bank. All patients had venous blood samples collected prior to surgery and 6 months after the procedure. Anti-HLA analysis for the detection of HLA (human leukocyte antigen) antibodies was performed using methods such as the LABScreen PRA Class I and Class II, LABScreen Single Antigen Class I and Class II, Luminex Platform. Reactive individuals to the screening tests (LABScreen PRA) were further investigated to determine the specificity of the antibodies detected (LABScreen Single Antigen) with a cutoff value of median fluorescence intensity ≥500. As a result, it was observed that two patients (33%) were positive in screening tests, one presenting with anti-HLA Class I and II sensitization and the other with anti-HLA class II. The specificity analysis showed that the patients sensitized to HLA class II presented 4 specificities, 3 of which immunologically relevant. In the second individual, 23 specificities were identified, 6 of which immunologically important for HLA class I and 4 specificities for HLA class II, 3 of these were immunologically important. All specificities detected had average fluorescence. These findings are suggestive that sinus-lifting procedures with allogeneic bone can induce immunological sensitization.

  17. Normalization of urinary drug concentrations with specific gravity and creatinine.

    PubMed

    Cone, Edward J; Caplan, Yale H; Moser, Frank; Robert, Tim; Shelby, Melinda K; Black, David L

    2009-01-01

    Excessive fluid intake can substantially dilute urinary drug concentrations and result in false-negative reports for drug users. Methods for correction ("normalization") of drug/metabolite concentrations in urine have been utilized by anti-doping laboratories, pain monitoring programs, and in environmental monitoring programs to compensate for excessive hydration, but such procedures have not been used routinely in workplace, legal, and treatment settings. We evaluated two drug normalization procedures based on specific gravity and creatinine. These corrections were applied to urine specimens collected from three distinct groups (pain patients, heroin users, and marijuana/ cocaine users). Each group was unique in characteristics, study design, and dosing conditions. The results of the two normalization procedures were highly correlated (r=0.94; range, 0.78-0.99). Increases in percent positives by specific gravity and creatinine normalization were small (0.3% and -1.0%, respectively) for heroin users (normally hydrated subjects), modest (4.2-9.8%) for pain patients (unknown hydration state), and substantial (2- to 38-fold increases) for marijuana/cocaine users (excessively hydrated subjects). Despite some limitations, these normalization procedures provide alternative means of dealing with highly dilute, dilute, and concentrated urine specimens. Drug/metabolite concentration normalization by these procedures is recommended for urine testing programs, especially as a means of coping with dilute specimens.

  18. Controlled Retrieval of Specific Context Information in Children and Adults.

    PubMed

    Lorsbach, Thomas C; Friehe, Mary J; Teten, Amy Fair; Reimer, Jason F; Armendarez, Joseph J

    2015-01-01

    This study adapted a procedure used by Luo and Craik (2009) to examine whether developmental differences exist in the ability to use controlled retrieval processes to access the contextual details of memory representations. Participants from 3 age groups (mean ages 9, 12, and 25 years) were presented with words in 3 study contexts: with a black-and-white picture, with a color picture, or alone without a picture. Six recognition tests were then presented that varied in the demands (high or low) placed on the retrieval of specific contextual information. Each test consisted of a mixture of words that were old targets from 1 study context, distractors (i.e., previously studied words from a different context), and completely new words. A high-specificity and a low-specificity test list was paired with each test question, with high and low specificity being determined by the nature of the distractors used in a test list. High-specificity tests contained words that were studied in similar contexts: old targets (e.g., words studied with black-and-white pictures) and distractors (e.g., words studied with color pictures). In contrast, low-specificity tests contained words that were studied in dissimilar contexts: old targets (e.g., words studied with black-and-white pictures) and distractors (e.g., words previously studied without a picture). Relative to low-specificity tests, the retrieval conditions of high-specificity tests were assumed to place greater demands on the controlled access of specific contextual information. Analysis of recollection scores revealed that age differences were present on high-but not low-specificity tests, with the performance of 9-year-olds disproportionately affected by the retrieval demands of high-specificity tests.

  19. Optimization of a gene electrotransfer procedure for efficient intradermal immunization with an hTERT-based DNA vaccine in mice

    PubMed Central

    Calvet, Christophe Y; Thalmensi, Jessie; Liard, Christelle; Pliquet, Elodie; Bestetti, Thomas; Huet, Thierry; Langlade-Demoyen, Pierre; Mir, Lluis M

    2014-01-01

    DNA vaccination consists in administering an antigen-encoding plasmid in order to trigger a specific immune response. This specific vaccine strategy is of particular interest to fight against various infectious diseases and cancer. Gene electrotransfer is the most efficient and safest non-viral gene transfer procedure and specific electrical parameters have been developed for several target tissues. Here, a gene electrotransfer protocol into the skin has been optimized in mice for efficient intradermal immunization against the well-known telomerase tumor antigen. First, the luciferase reporter gene was used to evaluate gene electrotransfer efficiency into the skin as a function of the electrical parameters and electrodes, either non-invasive or invasive. In a second time, these parameters were tested for their potency to generate specific cellular CD8 immune responses against telomerase epitopes. These CD8 T-cells were fully functional as they secreted IFNγ and were endowed with specific cytotoxic activity towards target cells. This simple and optimized procedure for efficient gene electrotransfer into the skin using the telomerase antigen is to be used in cancer patients for the phase 1 clinical evaluation of a therapeutic cancer DNA vaccine called INVAC-1. PMID:26015983

  20. Evaluation of chemical data from selected sites in the Surface-Water Ambient Monitoring Program (SWAMP) in Florida

    USGS Publications Warehouse

    Katz, B.G.; Collins, J.J.

    1998-01-01

    A cooperative study between the Florida Department of Environmental Protection (FDEP) and the U.S. Geological Survey was conducted to assess the integrity of selected water-quality data collected at 150 sites in the FDEP Surface-Water Ambient Monitoring Program (SWAMP) in Florida. The assessment included determining the consistency of the water-quality data collected statewide, including commonality of monitoring procedures and analytes, screening of the gross validity of a chemical analysis, and quality assurance and quality control (QA/QC) procedures. Four tests were used to screen data at selected SWAMP sites to estimate the gross validity of selected chemical data: (1) the ratio of dissolved solids (in milligrams per liter) to specific conductance (in microsiemens per centimeter); (2) the ratio of total cations (in milliequivalents per liter) multiplied by 100 to specific conductance (in microsiemens per centimeter); (3) the ratio of total anions (in milliequivalents per liter) multiplied by 100 to specific conductance (in microsiemens per centimeter); and (4) the ionic charge-balance error. Although the results of the four screening tests indicate that the chemical data generally are quite reliable, the extremely small number of samples (less than 5 percent of the total number of samples) with sufficient chemical information to run the tests may not provide a representative indication of the analytical accuracy of all laboratories in the program. In addition to the four screening tests, unusually low or high values were flagged for field and laboratory pH (less than 4.0 and greater than 9.0) and specific conductance (less than 10 and greater than 10,000 microsiemens per centimeter). The numbers of flagged data were less than 1 percent of the 19,937 water samples with pH values and less than 0.6 percent of the 16,553 water samples with specific conductance values. Thirty-four agencies responded to a detailed questionnaire that was sent to more than 60 agencies involved in the collection and analysis of surface-water-quality data for SWAMP. The purpose of the survey was to evaluate quality assurance methods and consistency of methods statewide. Information was compiled and summarized on monitoring network design, data review and upload procedures, laboratory and field sampling methods, and data practices. Currently, most agencies that responded to the survey follow FDEP-approved QA/QC protocol for sampling and have quality assurance practices for recording and reporting data. Also, most agencies responded that calibration procedures were followed in the laboratory for analysis of data, but no responses were given about the specific procedures. Approximately 50 percent of the respondents indicated that laboratory analysis methods have changed over time. With so many laboratories involved in analyzing samples for SWAMP, it is difficult to compare water quality from one site to another due to different reporting conventions for chemical constituents and different analytical methods over time. Most agencies responded that calibration methods are followed in the field, but no specific details were provided. Grab samples are the most common method of collection. Other data screening procedures are necessary to further evaluate the validity of chemical data collected at SWAMP sites. High variability in the concentration of targeted constituents may signal analytical problems, but more likely changes in concentration are related to hydrologic conditions. This underscores the need for accurate measurements of discharge, lake stage, tidal stage at the time of sampling so that changes in constituent concentrations can be properly evaluated and fluxes (loads) of nutrients or metals, for example, can be calculated and compared over time.

  1. Consequences of common data analysis inaccuracies in CNS trauma injury basic research.

    PubMed

    Burke, Darlene A; Whittemore, Scott R; Magnuson, David S K

    2013-05-15

    The development of successful treatments for humans after traumatic brain or spinal cord injuries (TBI and SCI, respectively) requires animal research. This effort can be hampered when promising experimental results cannot be replicated because of incorrect data analysis procedures. To identify and hopefully avoid these errors in future studies, the articles in seven journals with the highest number of basic science central nervous system TBI and SCI animal research studies published in 2010 (N=125 articles) were reviewed for their data analysis procedures. After identifying the most common statistical errors, the implications of those findings were demonstrated by reanalyzing previously published data from our laboratories using the identified inappropriate statistical procedures, then comparing the two sets of results. Overall, 70% of the articles contained at least one type of inappropriate statistical procedure. The highest percentage involved incorrect post hoc t-tests (56.4%), followed by inappropriate parametric statistics (analysis of variance and t-test; 37.6%). Repeated Measures analysis was inappropriately missing in 52.0% of all articles and, among those with behavioral assessments, 58% were analyzed incorrectly. Reanalysis of our published data using the most common inappropriate statistical procedures resulted in a 14.1% average increase in significant effects compared to the original results. Specifically, an increase of 15.5% occurred with Independent t-tests and 11.1% after incorrect post hoc t-tests. Utilizing proper statistical procedures can allow more-definitive conclusions, facilitate replicability of research results, and enable more accurate translation of those results to the clinic.

  2. Rationale for windshield glass system specification requirements for shuttle orbiter

    NASA Technical Reports Server (NTRS)

    Hayashida, K.; King, G. L.; Tesinsiky, J.; Wittenburg, D. R.

    1972-01-01

    A preliminary procurement specification for the space shuttle orbiter windshield pane, and some of the design considerations and rationale leading to its development are presented. The windshield designer is given the necessary methods and procedures for assuring glass pane structural integrity by proof test. These methods and procedures are fully developed for annealed and thermally tempered aluminosilicate, borosilicate, and soda lime glass and for annealed fused silica. Application of the method to chemically tempered glass is considered. Other considerations are vision requirements, protection against bird impact, hail, frost, rain, and meteoroids. The functional requirements of the windshield system during landing, ferrying, boost, space flight, and entry are included.

  3. Florida specific NTCIP MIB development for actuated signal controller (ASC), closed-circuit television (CCTV), and center-to-center (C2C) communications with SunGuideSM software and ITS device test procedure development : summary of final report.

    DOT National Transportation Integrated Search

    2009-06-01

    To provide hardware, software, network, systems research, and testing for multi-million dollar traffic : operations, Intelligent Transportation Systems (ITS), and statewide communications investments, the : Traffic Engineering and Operations Office h...

  4. Florida specific NTCIP MIB development for actuated signal controller (ASC), closed-circuit television (CCTV), and center-to-center (C2C) communications with SunGuideSM software and ITS device test procedure development : executive summary.

    DOT National Transportation Integrated Search

    2009-06-01

    To provide hardware, software, network, systems research, and testing for multi-million : dollar traffic operations, Intelligent Transportation Systems (ITS), and statewide : communications investments, the Traffic Engineering and Operations Office h...

  5. 46 CFR 159.005-11 - Approval inspection or test report: Contents.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Approval inspection or test report: Contents. 159.005-11 Section 159.005-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND MATERIALS Approval Procedures § 159.005-11 Approval inspection or tes...

  6. 10 CFR 70.39 - Specific licenses for the manufacture or initial transfer of calibration or reference sources.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... and design; (iii) Details of the method of incorporation and binding of the plutonium in the source; (iv) Procedures for and results of prototype testing of sources, which are designed to contain more... experimental studies and tests, required by the Commission to facilitate a determination of the safety of the...

  7. The Composition of the TV Picture: Suggested Hypotheses to Test the Forces That Operate within the Television Screen.

    ERIC Educational Resources Information Center

    Metallinos, Nikos

    This paper suggests specific experimental designs, criteria measures, and testing procedures for the empirical study of various field forces operative in the structure of the television picture. The purpose of the paper is twofold: first, to illustrate, through selected videotapes, the various field forces and, second, to provide specific…

  8. 76 FR 31951 - Energy Conservation Program for Certain Commercial and Industrial Equipment: Decision and Order...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-02

    ... specific to the Carrier Super Modular Multi-System (SMMSi) variable refrigerant flow (VRF) multi-split... in this notice to test and rate its SMMSi VRF multi-split commercial heat pumps. DATES: This Decision... its SMMSi VRF multi-split products. Carrier must use the alternate test procedure provided in this...

  9. 46 CFR 159.005-11 - Approval inspection or test report: Contents.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Approval inspection or test report: Contents. 159.005-11 Section 159.005-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND MATERIALS Approval Procedures § 159.005-11 Approval inspection or tes...

  10. Anxiety-free Urinalysis.

    ERIC Educational Resources Information Center

    Schwartz, Marjorie F.

    1989-01-01

    Discusses simple analysis of urine in the classroom. Describes the materials and procedures for the analysis. Provides a laboratory report giving characteristics of: (1) odor, color, and clarity; (2) specific gravity; (3) sediment; (4) test strips; and (5) albumin and phosphates. (YP)

  11. Stand Alone Pressure Measurement Device (SAPMD) for the space shuttle Orbiter, part 2

    NASA Technical Reports Server (NTRS)

    Tomlinson, Bill

    1989-01-01

    The Stand Alone Pressure Measurement Device (SAPMD) specifications are examined. The HP.SAPMD GSE software is listed; the HP/SGA readme program is presented; and the SPMD acceptance test procedure is described.

  12. Alternative to Nitric Acid Passivation Project Overview

    NASA Technical Reports Server (NTRS)

    Lewis, Pattie L.

    2013-01-01

    The standard practice for protection of stainless steel is a process called passivation. This procedure results in the formation of a metal oxide layer to prevent corrosion. Typical passivation procedures call for the use of nitric acid which exhibits excellent corrosion performance; however, there are a number of environmental, worker safety, and operational issues associated with its use. The longtime military specification for the passivation of stainless steel was cancelled in favor of newer specifications which allow for the use of citric acid in place of nitric acid. Citric acid offers a variety of benefits that include increased safety for personnel, reduced environmental impact, and reduced operational costs. There have been few studies, however, to determine whether citric acid is an acceptable alternative for NASA and DoD. This paper details activities to date including development of the joint test plan, on-going and planned testing, and preliminary results.

  13. Performance characterization of structured light-based fingerprint scanner

    NASA Astrophysics Data System (ADS)

    Hassebrook, Laurence G.; Wang, Minghao; Daley, Raymond C.

    2013-05-01

    Our group believes that the evolution of fingerprint capture technology is in transition to include 3-D non-contact fingerprint capture. More specifically we believe that systems based on structured light illumination provide the highest level of depth measurement accuracy. However, for these new technologies to be fully accepted by the biometric community, they must be compliant with federal standards of performance. At present these standards do not exist for this new biometric technology. We propose and define a set of test procedures to be used to verify compliance with the Federal Bureau of Investigation's image quality specification for Personal Identity Verification single fingerprint capture devices. The proposed test procedures include: geometric accuracy, lateral resolution based on intensity or depth, gray level uniformity and flattened fingerprint image quality. Several 2-D contact analogies, performance tradeoffs and optimization dilemmas are evaluated and proposed solutions are presented.

  14. Nevada Applied Ecology Group procedures handbook for environmental transuranics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, M.G.; Dunaway, P.B.

    The activities of the Nevada Applied Ecology Group (NAEG) integrated research studies of environmental plutonium and other transuranics at the Nevada Test Site have required many standardized field and laboratory procedures. These include sampling techniques, collection and preparation, radiochemical and wet chemistry analysis, data bank storage and reporting, and statistical considerations for environmental samples of soil, vegetation, resuspended particles, animals, and others. This document, printed in two volumes, includes most of the Nevada Applied Ecology Group standard procedures, with explanations as to the specific applications involved in the environmental studies. Where there is more than one document concerning a procedure,more » it has been included to indicate special studies or applications perhaps more complex than the routine standard sampling procedures utilized.« less

  15. Nevada Applied Ecology Group procedures handbook for environmental transuranics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, M.G.; Dunaway, P.B.

    The activities of the Nevada Applied Ecology Group (NAEG) integrated research studies of environmental plutonium and other transuranics at the Nevada Test Site have required many standardized field and laboratory procedures. These include sampling techniques, collection and preparation, radiochemical and wet chemistry analysis, data bank storage and reporting, and statistical considerations for environmental samples of soil, vegetation, resuspended particles, animals, and other biological material. This document, printed in two volumes, includes most of the Nevada Applied Ecology Group standard procedures, with explanations as to the specific applications involved in the environmental studies. Where there is more than one document concerningmore » a procedure, it has been included to indicate special studies or applications more complex than the routine standard sampling procedures utilized.« less

  16. Determination of photovoltaic concentrator optical design specifications using performance modeling

    NASA Astrophysics Data System (ADS)

    Kerschen, Kevin A.; Levy, Sheldon L.

    The strategy used to develop an optical design specification for a 500X concentration photovoltaic module to be used with a 28-percent-efficient concentrator photovoltaic cell is reported. The computer modeling code (PVOPTICS) developed for this purpose, a Fresnel lens design strategy, and optical component specification procedures are described. Comparisons are made between the predicted performance and the measured performance of components fabricated to those specifications. An acrylic lens and a reflective secondary optical element have been tested, showing efficiencies exceeding 88 percent.

  17. Demonstration of frequency-sweep testing technique using a Bell 214-ST helicopter

    NASA Technical Reports Server (NTRS)

    Tischler, Mark B.; Fletcher, Jay W.; Diekmann, Vernon L.; Williams, Robert A.; Cason, Randall W.

    1987-01-01

    A demonstration of frequency-sweep testing using a Bell-214ST single-rotor helicopter was completed in support of the Army's development of an updated MIL-H-8501A, and an LHX (ADS-33) handling-qualities specification. Hover and level-flight (V sub a = 0 knots and V sub a = 90 knots) tests were conducted in 3 flight hours by Army test pilots at the Army Aviation Engineering Flight Activity (AEFA) at Edwards AFB, Calif. Bandwidth and phase-delay parameters were determined from the flight-extracted frequency responses as required by the proposed specifications. Transfer function modeling and verification demonstrates the validity of the frequency-response concept for characterizing closed-loop flight dynamics of single-rotor helicopters -- even in hover. This report documents the frequency-sweep flight-testing technique and data-analysis procedures. Special emphasis is given to piloting and analysis considerations which are important for demonstrating frequency-domain specification compliance.

  18. The Controlled Retrieval of Specific Context Information in Children and Adults

    PubMed Central

    Lorsbach, Thomas C.; Reimer, Jason F.; Friehe, Mary J.; Armendarez, Joseph J.; Teten, Amy Fair

    2017-01-01

    The present study adapted a procedure used recently by Luo and Craik (2009) in order to examine whether developmental differences exist in the ability to use controlled retrieval processes to access the specific contextual details of memory representations. Participants from three age groups (Mean ages: 9, 12, and 25 years) were presented with words in three study contexts: with a black-and-white picture, with a color picture, or alone without a picture. Six recognition tests were then presented that varied in the demands (high or low) placed on the retrieval of specific contextual information. Each test consisted of a mixture of words that were old targets from one study context, distractors (i.e., previously studied words from a different context), and completely new words. A “high specificity” and a “low specificity” test list was paired with each test question, with “high” and “low” specificity being determined by the nature of the distractors used in a test list. High specificity tests contained words that were studied in similar contexts: old targets (e.g., words studied with black-and-white pictures) and distractors (e.g., words studied with color pictures). In contrast, low specificity tests contained words that were studied in dissimilar contexts: old targets (e.g., words studied with black-and-white pictures) and distractors (e.g., words previously studied without a picture). Relative to low specificity tests, the retrieval conditions of high specificity tests were assumed to place greater demands on the controlled access of specific contextual information. Analysis of recollection scores revealed that age differences were present on high, but not low specificity tests, with the performance of 9-year olds being disproportionately affected by the retrieval demands of high specificity tests. PMID:26219173

  19. A generalized procedure for analyzing sustained and dynamic vocal fold vibrations from laryngeal high-speed videos using phonovibrograms.

    PubMed

    Unger, Jakob; Schuster, Maria; Hecker, Dietmar J; Schick, Bernhard; Lohscheller, Jörg

    2016-01-01

    This work presents a computer-based approach to analyze the two-dimensional vocal fold dynamics of endoscopic high-speed videos, and constitutes an extension and generalization of a previously proposed wavelet-based procedure. While most approaches aim for analyzing sustained phonation conditions, the proposed method allows for a clinically adequate analysis of both dynamic as well as sustained phonation paradigms. The analysis procedure is based on a spatio-temporal visualization technique, the phonovibrogram, that facilitates the documentation of the visible laryngeal dynamics. From the phonovibrogram, a low-dimensional set of features is computed using a principle component analysis strategy that quantifies the type of vibration patterns, irregularity, lateral symmetry and synchronicity, as a function of time. Two different test bench data sets are used to validate the approach: (I) 150 healthy and pathologic subjects examined during sustained phonation. (II) 20 healthy and pathologic subjects that were examined twice: during sustained phonation and a glissando from a low to a higher fundamental frequency. In order to assess the discriminative power of the extracted features, a Support Vector Machine is trained to distinguish between physiologic and pathologic vibrations. The results for sustained phonation sequences are compared to the previous approach. Finally, the classification performance of the stationary analyzing procedure is compared to the transient analysis of the glissando maneuver. For the first test bench the proposed procedure outperformed the previous approach (proposed feature set: accuracy: 91.3%, sensitivity: 80%, specificity: 97%, previous approach: accuracy: 89.3%, sensitivity: 76%, specificity: 96%). Comparing the classification performance of the second test bench further corroborates that analyzing transient paradigms provides clear additional diagnostic value (glissando maneuver: accuracy: 90%, sensitivity: 100%, specificity: 80%, sustained phonation: accuracy: 75%, sensitivity: 80%, specificity: 70%). The incorporation of parameters describing the temporal evolvement of vocal fold vibration clearly improves the automatic identification of pathologic vibration patterns. Furthermore, incorporating a dynamic phonation paradigm provides additional valuable information about the underlying laryngeal dynamics that cannot be derived from sustained conditions. The proposed generalized approach provides a better overall classification performance than the previous approach, and hence constitutes a new advantageous tool for an improved clinical diagnosis of voice disorders. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Realistic Vascular Replicator for TAVR Procedures.

    PubMed

    Rotman, Oren M; Kovarovic, Brandon; Sadasivan, Chander; Gruberg, Luis; Lieber, Baruch B; Bluestein, Danny

    2018-04-13

    Transcatheter aortic valve replacement (TAVR) is an over-the-wire procedure for treatment of severe aortic stenosis (AS). TAVR valves are conventionally tested using simplified left heart simulators (LHS). While those provide baseline performance reliably, their aortic root geometries are far from the anatomical in situ configuration, often overestimating the valves' performance. We report on a novel benchtop patient-specific arterial replicator designed for testing TAVR and training interventional cardiologists in the procedure. The Replicator is an accurate model of the human upper body vasculature for training physicians in percutaneous interventions. It comprises of fully-automated Windkessel mechanism to recreate physiological flow conditions. Calcified aortic valve models were fabricated and incorporated into the Replicator, then tested for performing TAVR procedure by an experienced cardiologist using the Inovare valve. EOA, pressures, and angiograms were monitored pre- and post-TAVR. A St. Jude mechanical valve was tested as a reference that is less affected by the AS anatomy. Results in the Replicator of both valves were compared to the performance in a commercial ISO-compliant LHS. The AS anatomy in the Replicator resulted in a significant decrease of the TAVR valve performance relative to the simplified LHS, with EOA and transvalvular pressures comparable to clinical data. Minor change was seen in the mechanical valve performance. The Replicator showed to be an effective platform for TAVR testing. Unlike a simplified geometric anatomy LHS, it conservatively provides clinically-relevant outcomes and complement it. The Replicator can be most valuable for testing new valves under challenging patient anatomies, physicians training, and procedural planning.

Top