Cho, Jae Hoon; Suh, Jeffrey D; Kim, Jin Kook; Hong, Seok-Chan; Park, Il-Ho; Lee, Heung-Man
2014-01-01
Allergy test results can differ based on the method used. The most common tests include skin-prick testing (SPT) and in vitro tests to detect allergen-specific IgE. This study was designed to assess allergy test results using SPT, individual specific IgE tests, and a multiallergen IgE assay (multiple allergen simultaneous test) in patients with chronic rhinitis and controls. One hundred forty total patients were prospectively enrolled in the study, including 100 patients with chronic rhinitis and 40 control patients without atopy. All eligible patients underwent SPT, serum analysis using individual specific IgE test, and multiple allergen simultaneous test against 10 common allergens. Allergy test results were then compared to identify correlation and interest agreement. There was an 81-97% agreement between SPT and individual specific IgE test in allergen detection and an 80-98% agreement between SPT and multiple allergen simultaneous test. Individual specific IgE test and multiple allergen simultaneous test allergy detection prevalence was generally similar to SPT in patients with chronic rhinitis. All control patients had negative SPT (0/40), but low positive results were found with both individual specific IgE test (5-12.5%) and multiple allergen simultaneous test (2.5-7.5%) to some allergens, especially cockroach, Dermatophagoides farina, and ragweed. Agreement and correlation between individual specific IgE test and multiple allergen simultaneous test were good to excellent for a majority of tested allergens. This study shows good agreement and correlation between SPT with individual specific IgE test and multiple allergen simultaneous test on a majority of the tested allergens for patients with chronic rhinitis. Comparing the two in vitro tests, individual specific IgE test agrees with SPT better than multiple allergen simultaneous test.
Sensitivity and specificity of presumptive tests for blood, saliva and semen.
Vennemann, Marielle; Scott, Georgina; Curran, Lynn; Bittner, Felix; Tobe, Shanan S
2014-03-01
Despite their wide use, the limits of presumptive tests can be poorly understood. The aim of this study was to investigate the specificity and sensitivity of conventional, as well as innovative, presumptive tests for blood, semen and saliva. We investigated Kastle-Meyer (KM) and leucomalachite green (LMG) tests for blood with regard to their sensitivity and specificity in the presence of oxidizing (hypochlorite) and anti-oxidizing (ascorbic acid) agents. The suitability and specificity of the red starch paper (RSP) test for saliva was assessed. Finally, the inhibitory effect of detergent on the acid phosphatase (AP) test for semen was investigated along with possible cross reactions to tea stains. Our results confirm previous findings of higher sensitivity and specificity of the KM test compared to LMG test for blood. Contrary to previous studies, no statistically significant difference was observed in the sensitivity of the tests between dry and wet stains. The novel RSP test was found to successfully detect saliva. We demonstrated that acid phosphatase (AP) testing for semen is possible on used RSP. A common multipurpose detergent had an inhibitory effect on AP tests. False positive results were obtained from tea stains. Testing different sorts of tea (black, green and herbal teas) revealed that only Camellia varieties produce positive result with the AP test, due to AP being present in the plants. From our results we conclude that specific knowledge of each test, including substances that may affect the test outcome, is imperative to ensure correct interpretation of presumptive test results.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 32 2014-07-01 2014-07-01 false Test results. 799.12 Section 799.12...) IDENTIFICATION OF SPECIFIC CHEMICAL SUBSTANCE AND MIXTURE TESTING REQUIREMENTS General Provisions § 799.12 Test results. Except as set forth in specific chemical test rules in subpart B of this part, a positive or...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 32 2011-07-01 2011-07-01 false Test results. 799.12 Section 799.12...) IDENTIFICATION OF SPECIFIC CHEMICAL SUBSTANCE AND MIXTURE TESTING REQUIREMENTS General Provisions § 799.12 Test results. Except as set forth in specific chemical test rules in subpart B of this part, a positive or...
Van Hoeyveld, Erna; Nickmans, Silvie; Ceuppens, Jan L; Bossuyt, Xavier
2015-10-23
Cut-off values and predictive values are used for the clinical interpretation of specific IgE antibody results. However, cut-off levels are not well defined, and predictive values are dependent on the prevalence of disease. The objective of this study was to document clinically relevant diagnostic accuracy of specific IgE for inhalant allergens (grass pollen and birch pollen) based on test result interval-specific likelihood ratios. Likelihood ratios are independent of the prevalence and allow to provide diagnostic accuracy information for test result intervals. In a prospective study we included consecutive adult patients presenting at an allergy clinic with complaints of rhinitis or rhinoconjunctivitis. The standard for diagnosis was a suggestive clinical history of grass or birch pollen allergy and a positive skin test. Specific IgE was determined with the ImmunoCAP Fluorescence Enzyme Immuno-Assay. We established specific IgE test result interval related likelihood ratios for clinical allergy to inhalant allergens (grass pollen, rPhl p 1,5, birch pollen, rBet v 1). The likelihood ratios for allergy increased with increasing specific IgE antibody levels. The likelihood ratio was <0.03 for specific IgE <0.1 kU/L, between 0.1 and 1.4 for specific IgE between 0.1 kU/L and 0.35 kU/L, between 1.4 and 4.2 for specific IgE between 0.35 kU/L and 3.5 kU/L, >6.3 for specific IgE>0.7, and very high (∞) for specific IgE >3.5 kU/L. Test result interval specific likelihood ratios provide a useful tool for the interpretation of specific IgE test results for inhalant allergens. Copyright © 2015 Elsevier B.V. All rights reserved.
Sekulic, Damir; Uljevic, Ognjen; Peric, Mia; Spasic, Miodrag; Kondric, Miran
2017-01-01
Abstract Agility is an important quality in tennis, yet there is an evident lack of studies focussing on the applicability of tennis-specific agility performances and comparing them to equivalent non-specific agility performances. The aim of this study was to evaluate the reliability and factorial validity of three tests of pre-planned agility, performed in specific (with a tennis racquet) and non-specific (without a tennis racquet) conditions. The sample consisted of 33 tennis players (13 males and 20 females; age: 18.3 ± 1.1 years and 18.6 ± 1.3 years; body height: 185.4 ± 51 cm and 169.3 ± 4.2 cm, 74.0 ± 4.4 kg and 61.2 ± 3.1 kg, respectively). The variables comprised three agility tests: a 20-yard test, a T-test and the Illinois test, all performed in both specific and non-specific conditions. Between-subject and within-subject reliability were found to be high (Cronbach Alpha: 0.93 to 0.98; Coefficient of Variation: 3 to 8%), with better within-subject reliability and stability of the measurement for specific tests. Pearson’s product moment correlations between the non-specific and specific agility performances were high (r ≥0.84), while factor analysis extracted only one significant latent dimension on the basis of the Guttman-Kaiser criterion. The results of the 20-yard test were better when the test was conducted in the specific conditions (t-test = 2.66; p < 0.05). For the Illinois test, superior results were recorded in the non-specific conditions (t-test = 2.96; p < 0.05), which can be explained by the test duration (about 20 s) and non-specific locomotion forms such as rotational movements. Considering the findings of the present study, when testing tennis-specific pre-planned agility, we suggest using tests of short duration (less than 10 s) and sport-specific types of locomotion. PMID:28210343
Negative and Positive Testing Effects in Terms of Item-Specific and Relational Information
ERIC Educational Resources Information Center
Mulligan, Neil W.; Peterson, Daniel J.
2015-01-01
Though retrieving information typically results in improved memory on a subsequent test (the testing effect), Peterson and Mulligan (2013) outlined the conditions under which retrieval practice results in poorer recall relative to restudy, a phenomenon dubbed the "negative testing effect." The item-specific-relational account proposes…
42 CFR 493.1253 - Standard: Establishment and verification of performance specifications.
Code of Federal Regulations, 2014 CFR
2014-10-01
... establish performance specifications for any test system used by the laboratory before April 24, 2003. (b)(1... approved test system must do the following before reporting patient test results: (i) Demonstrate that it... following performance characteristics: (A) Accuracy. (B) Precision. (C) Reportable range of test results for...
42 CFR 493.1253 - Standard: Establishment and verification of performance specifications.
Code of Federal Regulations, 2013 CFR
2013-10-01
... establish performance specifications for any test system used by the laboratory before April 24, 2003. (b)(1... approved test system must do the following before reporting patient test results: (i) Demonstrate that it... following performance characteristics: (A) Accuracy. (B) Precision. (C) Reportable range of test results for...
42 CFR 493.1253 - Standard: Establishment and verification of performance specifications.
Code of Federal Regulations, 2012 CFR
2012-10-01
... establish performance specifications for any test system used by the laboratory before April 24, 2003. (b)(1... approved test system must do the following before reporting patient test results: (i) Demonstrate that it... following performance characteristics: (A) Accuracy. (B) Precision. (C) Reportable range of test results for...
42 CFR 493.1253 - Standard: Establishment and verification of performance specifications.
Code of Federal Regulations, 2011 CFR
2011-10-01
... establish performance specifications for any test system used by the laboratory before April 24, 2003. (b)(1... approved test system must do the following before reporting patient test results: (i) Demonstrate that it... following performance characteristics: (A) Accuracy. (B) Precision. (C) Reportable range of test results for...
Faying Surface Lubrication Effects on Nut Factors
NASA Technical Reports Server (NTRS)
Taylor, Deneen M.; Morrison, Raymond F.
2006-01-01
Bolted joint analysis typically is performed using nut factors derived from textbooks and procedures from program requirement documents. Joint specific testing was performed for a critical International Space Station (ISS) joint. Test results indicate that for some configurations the nut factor may be significantly different than accepted textbook values. This paper presents results of joint specific testing to aid in determining if joint specific testing should be performed to insure required preloads are obtained.
A Performance Comparison of Color Vision Tests for Military Screening.
Walsh, David V; Robinson, James; Jurek, Gina M; Capó-Aponte, José E; Riggs, Daniel W; Temme, Leonard A
2016-04-01
Current color vision (CV) tests used for aviation screening in the U.S. Army only provide pass-fail results, and previous studies have shown variable sensitivity and specificity. The purpose of this study was to evaluate seven CV tests to determine an optimal CV test screener that potentially could be implemented by the U.S. Army. There were 133 subjects [65 Color Vision Deficits (CVD), 68 Color Vision Normal (CVN)] who performed all of the tests in one setting. CVD and CVN determination was initially assessed with the Oculus anomaloscope. Each test was administered monocularly and according to the test protocol. The main outcome measures were test sensitivity, specificity, and administration time (automated tests). Three of the four Pseudoisochromatic Plate (PIP) tests had a sensitivity/specificity > 0.90 OD/OS, whereas the FALANT tests had a sensitivity/specificity > 0.80 OD/OS. The Cone Contrast Test (CCT) demonstrated sensitivity/specificity > 0.90 OD/OS, whereas the Color Assessment and Diagnosis (CAD) test demonstrated sensitivity/specificity > 0.85 OD/OS. Comparison with the anomaloscope ("gold standard") revealed no significant difference of sensitivity and specificity OD/OS with the CCT, Dvorine PIP, and PIPC tests. Finally, the CCT administration time was significantly faster than the CAD test. The current U.S. Army CV screening tests demonstrated good sensitivity and specificity, as did the automated tests. In addition, some current PIP tests (Dvorine, PIPC), and the CCT performed no worse statistically than the anomaloscope with regard to sensitivity/specificity. The CCT letter presentation is randomized and results would not be confounded by potential memorization, or fading, of book plates.
... These proteins work with the immune system. Normal Results A normal test result is called a negative ... meaning of your specific test results. What Abnormal Results Mean A positive test result means the results ...
... done to tell which condition someone has. Normal Results A normal test result is called a negative ... meaning of your specific test results. What Abnormal Results Mean An abnormal test result indicates the person ...
Comparison of serum specific IgE with skin prick test in the diagnosis of allergy in Malaysia.
Asha'ari, Z A; Suhaimi, Y; Yusof, R A; Rushdan, I; Maraina, C H C
2011-08-01
We compared a newer serum specific IgE (SSIgE) test with skin prick testing (SPT) in the diagnosis of allergy in Malaysia. Ninety newly diagnosed allergic patients were enrolled for both tests. Using SPT as a clinical gold standard, the sensitivity, specificity, positive, and negative predictive values (PPV, NPV) were calculated for SSIgE for each of the common allergens tested. The highest positive results for both SPT and SSIgE were for house dust mite and cat. Compared to SPT, SSIgE showed better sensitivity but poorer specificity, low PPV and good NPV in all the allergens tested. Significant positive correlation was seen between the diameter of wheal and flare of SPT and the SSIgE results.
The Impact of Human Capital on the Cost of Air Force Acquisition Programs
2007-03-01
inspection as well as an empirical test of the data. To empirically test for heteroskedasticty, the Breusch - Pagan /Cook-Weisberg test was used. With a p...19 Pre-Specification Tests ......................................................................................................20 Post...Specification Tests .....................................................................................................22 Regression Results
7 CFR 58.139 - Record of tests.
Code of Federal Regulations, 2011 CFR
2011-01-01
..., GENERAL SPECIFICATIONS FOR APPROVED PLANTS AND STANDARDS FOR GRADES OF DAIRY PRODUCTS 1 General Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Quality Specifications for Raw Milk § 58.139 Record of tests. Accurate records listing the results of quality and drug residue tests...
Daft, Barbara M; Barr, Bradd C; Gardner, Ian A; Read, Deryck; Bell, William; Peyser, Karen G; Ardans, Alex; Kinde, Hailu; Morrow, Jennifer K
2002-10-01
To determine sensitivity and specificity of western blot testing (WBT) of CSF and serum for diagnosis of equine protozoal myeloencephalitis (EPM) in horses with and without neurologic abnormalities. Prospective investigation. 65 horses with and 169 horses without neurologic abnormalities. CSF and serum from horses submitted for necropsy were tested for Sarcocystis neurona-specific antibody with a WBT. Results of postmortem examination were used as the gold standard against which results of the WBT were compared. Sensitivity of WBT of CSF was 87% for horses with and 88% for horses without neurologic abnormalities. Specificity of WBT of CSF was 44% for horses with and 60% for horses without neurologic abnormalities. Regardless of whether horses did or did not have neurologic abnormalities, sensitivity and specificity of WBT of serum were not significantly different from values for WBT of CSF. Ninety-four horses without EPM had histologic evidence of slight CNS inflammation. The low specificity of WBT of CSF indicated that it is inappropriate to diagnose EPM on the basis of a positive test result alone because of the possibility of false-positive test results. The high sensitivity, however, means that a negative result is useful in ruling out EPM. There was no advantage in testing CSF versus serum in horses without neurologic abnormalities. Slight CNS inflammation was common in horses with and without S neurona-specific antibodies in the CSF and should not be considered an indication of CNS infection with S neurona.
Mitchell, Rebecca; Thomas, Sunethra Devika; Langlois, Neil E I
2013-10-01
Biochemical analysis of glucose and ketones in the vitreous humour obtained at post-mortem examination is representative of the levels in the blood prior to death. Elevated levels can be indicative of conditions including diabetic ketoacidosis, which can be a cause for unexpected death. A rapid screening test for such conditions can be performed during the autopsy through urinalysis using test strips (urine 'dipstick' testing). The aim of this study was to assess the utility of urinalysis testing for post-mortem detection of derangements of glucose and ketone levels. The results of vitreous biochemical analysis and urinalysis were collated from 188 forensic autopsy cases. A vitreous glucose result of above 10 mmol/L was regarded as high. When this was compared to urinalysis results it was found that any urinalysis result above negative had a sensitivity of 0.83 and a specificity of 0.93. A vitreous ketone level of above 5 mmol/L was regarded as significantly elevated; a urinalysis result above negative had a sensitivity of 1, but a specificity of 0.12. Urinalysis ('dipstick' testing) for glucose has a good sensitivity and specificity for high vitreous glucose levels, which are regarded as indicative of pathological hyperglycaemia during life. It was found that urine testing for ketones either has an excellent sensitivity with low specificity or a poor sensitivity with a good specificity; however, this finding has to be viewed in the context of uncertainty of the biochemical level of significant ketosis.
Kuselman, Ilya; Pennecchi, Francesca R; da Silva, Ricardo J N B; Hibbert, D Brynn
2017-11-01
The probability of a false decision on conformity of a multicomponent material due to measurement uncertainty is discussed when test results are correlated. Specification limits of the components' content of such a material generate a multivariate specification interval/domain. When true values of components' content and corresponding test results are modelled by multivariate distributions (e.g. by multivariate normal distributions), a total global risk of a false decision on the material conformity can be evaluated based on calculation of integrals of their joint probability density function. No transformation of the raw data is required for that. A total specific risk can be evaluated as the joint posterior cumulative function of true values of a specific batch or lot lying outside the multivariate specification domain, when the vector of test results, obtained for the lot, is inside this domain. It was shown, using a case study of four components under control in a drug, that the correlation influence on the risk value is not easily predictable. To assess this influence, the evaluated total risk values were compared with those calculated for independent test results and also with those assuming much stronger correlation than that observed. While the observed statistically significant correlation did not lead to a visible difference in the total risk values in comparison to the independent test results, the stronger correlation among the variables caused either the total risk decreasing or its increasing, depending on the actual values of the test results. Copyright © 2017 Elsevier B.V. All rights reserved.
90/10 JP5/Synthesized ISO-Paraffin Specification and Fit-for-Purpose Test Results
2014-06-11
The minor discrepancies between these results are within the experimental error of the method and can be considered not significant. These results ...90/10 JP5/SYNTHESIZED ISO-PARAFFIN SPECIFICATION AND FIT-FOR-PURPOSE TEST RESULTS NAVAIR SYSCOM REPORT 441/14-010 11 June 2014 Prepared By...2 3.0 RESULTS & DISCUSSION
How You Can Get the Best Results with Home Use Tests
... Use Tests How You Can Get the Best Results With Home Use Tests Share Tweet Linkedin Pin ... follow all test instructions to get an accurate result. Most home tests require specific timing, materials, and ...
An Additive Manufacturing Test Artifact
Moylan, Shawn; Slotwinski, John; Cooke, April; Jurrens, Kevin; Donmez, M Alkan
2014-01-01
A test artifact, intended for standardization, is proposed for the purpose of evaluating the performance of additive manufacturing (AM) systems. A thorough analysis of previously proposed AM test artifacts as well as experience with machining test artifacts have inspired the design of the proposed test artifact. This new artifact is designed to provide a characterization of the capabilities and limitations of an AM system, as well as to allow system improvement by linking specific errors measured in the test artifact to specific sources in the AM system. The proposed test artifact has been built in multiple materials using multiple AM technologies. The results of several of the builds are discussed, demonstrating how the measurement results can be used to characterize and improve a specific AM system. PMID:26601039
Simulation verification techniques study: Simulation self test hardware design and techniques report
NASA Technical Reports Server (NTRS)
1974-01-01
The final results are presented of the hardware verification task. The basic objectives of the various subtasks are reviewed along with the ground rules under which the overall task was conducted and which impacted the approach taken in deriving techniques for hardware self test. The results of the first subtask and the definition of simulation hardware are presented. The hardware definition is based primarily on a brief review of the simulator configurations anticipated for the shuttle training program. The results of the survey of current self test techniques are presented. The data sources that were considered in the search for current techniques are reviewed, and results of the survey are presented in terms of the specific types of tests that are of interest for training simulator applications. Specifically, these types of tests are readiness tests, fault isolation tests and incipient fault detection techniques. The most applicable techniques were structured into software flows that are then referenced in discussions of techniques for specific subsystems.
Fish allergy in atopic children.
Peng, Y H; Shyur, S D; Chang, C L; Lai, C L; Chu, S H; Wu, W C; Wu, C Y
2001-12-01
The prevalence of fish allergy among 11 atopic children with elevated levels of specific immunoglobulin (Ig) E for cod was determined. None of the children had a history of fish allergy. All of the children had asthma and allergic rhinitis and 5 of them had also atopic dermatitis. The children underwent allergy skin tests (codfish, tuna, catfish, salmon, flounder, and bass), specific IgE tests (salmon, trout, tuna, eel, and mackerel), and food challenge tests. Skin tests in cod-specific IgE-positive children were positive for codfish in 4 children, tuna in 2, catfish in 2, salmon in 6, flounder in one, and bass in 2. Three children had elevated specific IgE for salmon, 5 for trout, 8 for tuna, 4 for eel, and 4 for mackerel. Oral fish challenge with 10 g of fish did not result in positive reaction in any of the children. In conclusion, a positive food challenge test provided the only definitive confirmation of fish allergy, whereas positive allergy skin tests or positive specific IgE tests were less reliable. Skin tests and in vitro specific IgE assays were not correlated with clinical symptoms of fish allergy, and the results of these 2 tests did not correlate with each other in this study.
Force Limited Vibration Testing
NASA Technical Reports Server (NTRS)
Scharton, Terry; Chang, Kurng Y.
2005-01-01
This slide presentation reviews the concept and applications of Force Limited Vibration Testing. The goal of vibration testing of aerospace hardware is to identify problems that would result in flight failures. The commonly used aerospace vibration tests uses artificially high shaker forces and responses at the resonance frequencies of the test item. It has become common to limit the acceleration responses in the test to those predicted for the flight. This requires an analysis of the acceleration response, and requires placing accelerometers on the test item. With the advent of piezoelectric gages it has become possible to improve vibration testing. The basic equations have are reviewed. Force limits are analogous and complementary to the acceleration specifications used in conventional vibration testing. Just as the acceleration specification is the frequency spectrum envelope of the in-flight acceleration at the interface between the test item and flight mounting structure, the force limit is the envelope of the in-flight force at the interface . In force limited vibration tests, both the acceleration and force specifications are needed, and the force specification is generally based on and proportional to the acceleration specification. Therefore, force limiting does not compensate for errors in the development of the acceleration specification, e.g., too much conservatism or the lack thereof. These errors will carry over into the force specification. Since in-flight vibratory force data are scarce, force limits are often derived from coupled system analyses and impedance information obtained from measurements or finite element models (FEM). Fortunately, data on the interface forces between systems and components are now available from system acoustic and vibration tests of development test models and from a few flight experiments. Semi-empirical methods of predicting force limits are currently being developed on the basis of the limited flight and system test data. A simple two degree of freedom system is shown and the governing equations for basic force limiting results for this system are reviewed. The design and results of the shuttle vibration forces (SVF) experiments are reviewed. The Advanced Composition Explorer (ACE) also was used to validate force limiting. Test instrumentation and supporting equipment are reviewed including piezo-electric force transducers, signal processing and conditioning systems, test fixtures, and vibration controller systems. Several examples of force limited vibration testing are presented with some results.
[Results of testing of MINISKAN mobile gamma-ray camera and specific features of its design].
Utkin, V M; Kumakhov, M A; Blinov, N N; Korsunskiĭ, V N; Fomin, D K; Kolesnikova, N V; Tultaev, A V; Nazarov, A A; Tararukhina, O B
2007-01-01
The main results of engineering, biomedical, and clinical testing of MINISKAN mobile gamma-ray camera are presented. Specific features of the camera hardware and software, as well as the main technical specifications, are described. The gamma-ray camera implements a new technology based on reconstructive tomography, aperture encoding, and digital processing of signals.
... with a family history of birth defects Normal Results Normal levels of AFP, hCG, uE3, and inhibin ... meaning of your specific test results. What Abnormal Results Mean An abnormal test result does NOT mean ...
Performance of the dipstick screening test as a predictor of negative urine culture
Marques, Alexandre Gimenes; Doi, André Mario; Pasternak, Jacyr; Damascena, Márcio dos Santos; França, Carolina Nunes; Martino, Marinês Dalla Valle
2017-01-01
ABSTRACT Objective To investigate whether the urine dipstick screening test can be used to predict urine culture results. Methods A retrospective study conducted between January and December 2014 based on data from 8,587 patients with a medical order for urine dipstick test, urine sediment analysis and urine culture. Sensitivity, specificity, positive and negative predictive values were determined and ROC curve analysis was performed. Results The percentage of positive cultures was 17.5%. Nitrite had 28% sensitivity and 99% specificity, with positive and negative predictive values of 89% and 87%, respectively. Leukocyte esterase had 79% sensitivity and 84% specificity, with positive and negative predictive values of 51% and 95%, respectively. The combination of positive nitrite or positive leukocyte esterase tests had 85% sensitivity and 84% specificity, with positive and negative predictive values of 53% and 96%, respectively. Positive urinary sediment (more than ten leukocytes per microliter) had 92% sensitivity and 71% specificity, with positive and negative predictive values of 40% and 98%, respectively. The combination of nitrite positive test and positive urinary sediment had 82% sensitivity and 99% specificity, with positive and negative predictive values of 91% and 98%, respectively. The combination of nitrite or leukocyte esterase positive tests and positive urinary sediment had the highest sensitivity (94%) and specificity (84%), with positive and negative predictive values of 58% and 99%, respectively. Based on ROC curve analysis, the best indicator of positive urine culture was the combination of positives leukocyte esterase or nitrite tests and positive urinary sediment, followed by positives leukocyte and nitrite tests, positive urinary sediment alone, positive leukocyte esterase test alone, positive nitrite test alone and finally association of positives nitrite and urinary sediment (AUC: 0.845, 0.844, 0.817, 0.814, 0.635 and 0.626, respectively). Conclusion A negative urine culture can be predicted by negative dipstick test results. Therefore, this test may be a reliable predictor of negative urine culture. PMID:28444086
Incorporating uncertainty into medical decision making: an approach to unexpected test results.
Bianchi, Matt T; Alexander, Brian M; Cash, Sydney S
2009-01-01
The utility of diagnostic tests derives from the ability to translate the population concepts of sensitivity and specificity into information that will be useful for the individual patient: the predictive value of the result. As the array of available diagnostic testing broadens, there is a temptation to de-emphasize history and physical findings and defer to the objective rigor of technology. However, diagnostic test interpretation is not always straightforward. One significant barrier to routine use of probability-based test interpretation is the uncertainty inherent in pretest probability estimation, the critical first step of Bayesian reasoning. The context in which this uncertainty presents the greatest challenge is when test results oppose clinical judgment. It is this situation when decision support would be most helpful. The authors propose a simple graphical approach that incorporates uncertainty in pretest probability and has specific application to the interpretation of unexpected results. This method quantitatively demonstrates how uncertainty in disease probability may be amplified when test results are unexpected (opposing clinical judgment), even for tests with high sensitivity and specificity. The authors provide a simple nomogram for determining whether an unexpected test result suggests that one should "switch diagnostic sides.'' This graphical framework overcomes the limitation of pretest probability uncertainty in Bayesian analysis and guides decision making when it is most challenging: interpretation of unexpected test results.
Measurement of antinuclear antibodies and their fine specificities: time for a change in strategy?
Otten, Henny G; Brummelhuis, Walter J; Fritsch-Stork, Ruth; Leavis, Helen L; Wisse, Bram W; van Laar, Jacob M; Derksen, Ronald H W M
2017-01-01
The current strategy for antinuclear antibody (ANA) analysis involves screening for presence with a subsequent detailed analysis of their specificity. The aim of this study is to compare the clinical and financial efficacy of this strategy between different commercial tests in a large cohort of unselected patients. In all consecutive 1030 patients associations were defined between results from different ANA test systems and the pre-test probability for connective tissue disease (CTDs). Test systems were used for screening (ANA-IIF vs. CTD screen) and definition of their fine specificity (profile 3 line blot vs. CTD single analytes). Positive ANA-IIF and/or CTD screen results were found in 304 sera. Further analysis for ANA-specificity by profile 3 line blot and CTD single analytes showed 86 discrepant results of which more than a third are clinically relevant, with the CTD single analyte assay performing better than the line blot in supporting or confirming the presence of a CTD. Autoantigens present in one test but absent in the other were of minor practical use. The ANA screening and identification strategies currently employed are not cost-effective as 83% of tests were performed in order to find specific autoantibodies in patients without the fitting clinical signs or symptoms. This causes many unexpected positive results and subsequent confusion with regard to interpretation. We advocate that some autoantigens should be excluded from the line blot and CTD assays and propose the use of a cost-effective and selective ANA specificity testing purely based on clinical guidance.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Test results. 799.12 Section 799.12... results. Except as set forth in specific chemical test rules in subpart B of this part, a positive or negative test result in any of the tests required under subpart B is defined in the TSCA test guidelines...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 33 2013-07-01 2013-07-01 false Test results. 799.12 Section 799.12... results. Except as set forth in specific chemical test rules in subpart B of this part, a positive or negative test result in any of the tests required under subpart B is defined in the TSCA test guidelines...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 33 2012-07-01 2012-07-01 false Test results. 799.12 Section 799.12... results. Except as set forth in specific chemical test rules in subpart B of this part, a positive or negative test result in any of the tests required under subpart B is defined in the TSCA test guidelines...
Hydrogen test of a small, low specific speed centrifugal pump stage
NASA Technical Reports Server (NTRS)
1991-01-01
A small, low specific speed centrifugal pump stage with a 2 inch tip diameter, .030 inch tip width shrouded impeller and volute collector was tested with liquid hydrogen as the pumped fluid. The hydrodynamic design of the pump stage is summarized and the noncavitating and cavitating performance results are presented. Test speeds were 60 and 80 percent of the 77,000 rpm design speed. Liquid hydrogen test results are compared with data from previous tests of the stage in water.
DeBoer, D J; Hillier, A
2001-09-20
Serum-based in vitro "allergy tests" are commercially available to veterinarians, and are widely used in diagnostic evaluation of a canine atopic patient. Following initial clinical diagnosis, panels of allergen-specific IgE measurements may be performed in an attempt to identify to which allergens the atopic dog is hypersensitive. Methodology for these tests varies by laboratory; few critical studies have evaluated performance of these tests, and current inter-laboratory standardization and quality control measures are inadequate. Other areas where information is critically limited include the usefulness of these tests in diagnosis of food allergy, the effect of extrinsic factors such as season of the year on results, and the influence of corticosteroid treatment on test results. Allergen-specific IgE serological tests are never completely sensitive, nor completely specific. There is only partial correlation between the serum tests and intradermal testing; however, the significance of discrepant results is unknown and unstudied. Variation in test methodologies along with the absence of universal standardization and reporting procedures have created confusion, varying study results, and an inability to compare between studies performed by different investigators.
Intention to communicate BRCA1/BRCA2 genetic test results to the family.
Barsevick, Andrea M; Montgomery, Susan V; Ruth, Karen; Ross, Eric A; Egleston, Brian L; Bingler, Ruth; Malick, John; Miller, Suzanne M; Cescon, Terrence P; Daly, Mary B
2008-04-01
Guided by the theory of planned behavior, this analysis explores the communication skills of women who had genetic testing for BRCA1 and BRCA2. The key outcome was intention to tell test results to adult first-degree relatives. The theory predicts that global and specific attitudes, global and specific perceived social norms, and perceived control will influence the communication of genetic test results. A logistic regression model revealed that global attitude (p < .05), specific social influence (p < .01), and perceived control (p < .05) were significant predictors of intention to tell. When gender and generation of relatives were added to the regression, participants were more likely to convey genetic test results to female than to male relatives (p < .05) and were also more likely to communicate test results to children (p < .01) or siblings (p < .05) than to parents. However, this association depended on knowing the relative's opinion of genetic testing. Intention to tell was lowest among participants who did not know their relative's opinion. These results extend the theory of planned behavior by showing that gender and generation influence intention when the relative's opinion is unknown. (c) 2008 APA, all rights reserved.
Impact of Exposure to Pressure of 50 MPa on the Specific Surface Area of Clay
NASA Astrophysics Data System (ADS)
Koszela-Marek, Ewa
2017-12-01
The paper presents results of laboratory tests conducted to determine the impact of pressure of 50 MPa on specific surface area of clay. These tests were carried out in an original, high-pressure test stand. The specific surface area of clay extracted directly from an open pit mine was compared with the specific surface area of the same clay subjected to the pressure of 50 MPa in a high-pressure chamber. The study found that the specific surface area of the clay subjected to the pressure of 50 MPa increased distinctly by over 35 %. The increase in specific surface can be a result of changes in the microstructure of clay particles and microstructural alteration in the soil skeleton, caused by the pressure.
50/50 JP5/ATJ5 Specification and Fit-for-Purpose Test Results
2014-07-02
identical to the average CRC handbook JP-5 values. The minor discrepancies between these results are within the experimental error of the method and...50/50 JP5/ATJ5 SPECIFICATION AND FIT-FOR-PURPOSE TEST RESULTS NAVAIR SYSCOM REPORT 441/14-011 2 July 2014 Prepared By: Kristin L. Weisser...3 3.0 RESULTS & DISCUSSION
2012-01-01
Background Routine cytomegalovirus (CMV) screening during pregnancy is not recommended in the United States and the extent to which it is performed is unknown. Using a medical claims database, we computed rates of CMV-specific testing among pregnant women. Methods We used medical claims from the 2009 Truven Health MarketScan® Commercial databases. We computed CMV-specific testing rates using CPT codes. Results We identified 77,773 pregnant women, of whom 1,668 (2%) had a claim for CMV-specific testing. CMV-specific testing was significantly associated with older age, Northeast or urban residence, and a diagnostic code for mononucleosis. We identified 44 women with a diagnostic code for mononucleosis, of whom 14% had CMV-specific testing. Conclusions Few pregnant women had CMV-specific testing, suggesting that screening for CMV infection during pregnancy is not commonly performed. In the absence of national surveillance for CMV infections during pregnancy, healthcare claims are a potential source for monitoring practices of CMV-specific testing. PMID:23198949
NASA Technical Reports Server (NTRS)
Davidian, Kenneth J.; Dieck, Ronald H.; Chuang, Isaac
1987-01-01
A preliminary uncertainty analysis was performed for the High Area Ratio Rocket Nozzle test program which took place at the altitude test capsule of the Rocket Engine Test Facility at the NASA Lewis Research Center. Results from the study establish the uncertainty of measured and calculated parameters required for the calculation of rocket engine specific impulse. A generalized description of the uncertainty methodology used is provided. Specific equations and a detailed description of the analysis is presented. Verification of the uncertainty analysis model was performed by comparison with results from the experimental program's data reduction code. Final results include an uncertainty for specific impulse of 1.30 percent. The largest contributors to this uncertainty were calibration errors from the test capsule pressure and thrust measurement devices.
NASA Technical Reports Server (NTRS)
Davidian, Kenneth J.; Dieck, Ronald H.; Chuang, Isaac
1987-01-01
A preliminary uncertainty analysis has been performed for the High Area Ratio Rocket Nozzle test program which took place at the altitude test capsule of the Rocket Engine Test Facility at the NASA Lewis Research Center. Results from the study establish the uncertainty of measured and calculated parameters required for the calculation of rocket engine specific impulse. A generalized description of the uncertainty methodology used is provided. Specific equations and a detailed description of the analysis are presented. Verification of the uncertainty analysis model was performed by comparison with results from the experimental program's data reduction code. Final results include an uncertainty for specific impulse of 1.30 percent. The largest contributors to this uncertainty were calibration errors from the test capsule pressure and thrust measurement devices.
van Kampen, V; Rabstein, S; Sander, I; Merget, R; Brüning, T; Broding, H C; Keller, C; Müsken, H; Overlack, A; Schultze-Werninghaus, G; Walusiak, J; Raulf-Heimsoth, M
2008-07-01
Wheat and rye flours are among the most important allergens causing occupational asthma. Usually, the diagnosis of baker's asthma is based on inhalation challenge tests with flours. To evaluate the relevance of flour-specific serum immunoglobulin E (IgE) and skin prick test (SPT) in the diagnosis of baker's asthma and to define flour-specific IgE concentrations and wheal sizes that allow a prediction of the outcome of challenge testing. Bronchial and nasal challenge tests with wheat (rye) flour were performed in 71 (95) symptomatic bakers. Determinations of flour-specific IgE as well as SPTs were performed in all subjects. Analyses included the calculation of sensitivity, specificity, positive (PPV) and negative predictive values (NPV) at different IgE concentrations and different wheal sizes, and receiver-operating characteristics (ROC) plots with the challenge result as gold standard. Thirty-seven bakers were positive in the challenge with wheat flour, while 63 were positive with rye flour. Depending on the flour-specific IgE concentrations (wheal size), PPV was 74-100% (74-100%) for wheat and 82-100% (91-100%) for rye flour, respectively. The minimal cut-off values with a PPV of 100% were 2.32 kU/l (5.0 mm) for wheat flour and 9.64 kU/l (4.5 mm) for rye flour. The shapes of the ROC plots were similar for wheat and rye flour. High concentrations of flour-specific IgE and clear SPT results in symptomatic bakers are good predictors for a positive challenge test. Challenge tests with flours may be avoided in strongly sensitized bakers.
Zucker, Jane R.; Giancotti, Francesca R.; Abernathy, Emily; Icenogle, Joseph; Rakeman, Jennifer L.; Rosen, Jennifer B.
2017-01-01
ABSTRACT The New York City Department of Health and Mental Hygiene (DOHMH) receives clinical and laboratory reports for rubella. Because rubella immunoglobulin M (IgM) assays may produce false-positive results and rubella infections may be asymptomatic, interpretation of positive IgM results can be challenging. Rubella reports received by DOHMH in 2012 to 2013 were reviewed. The rubella IgM testing purpose was determined through case investigation. Results of IgM testing by indirect enzyme-linked immunosorbent assay (ELISA) and capture enzyme immunoassay (EIA) were compared to determine positive predictive value (PPV) and specificity. DOHMH received 199 rubella reports; 2 were true cases. Of all reports, 77.9% were tested for rubella IgM erroneously, 19.6% were tested for diagnostic purposes, 2.0% had unknown test purpose, and 0.5% were not tested. PPV of indirect ELISA was 6% overall, 14% for diagnostic tests, and 0% for tests ordered erroneously. PPV of capture EIA was 29% overall, 50% for diagnostic tests, and 0% for tests ordered erroneously. Overall, specificity was 52% for indirect ELISA and 85% for capture EIA. Limiting rubella IgM testing to patients for whom rubella diagnosis is suspected and using a more specific IgM assay have the potential to reduce false-positive rubella IgM results. PMID:28701468
Adriaens, E; Willoughby, J A; Meyer, B R; Blakeman, L C; Alépée, N; Fochtman, P; Guest, R; Kandarova, H; Verstraelen, S; Van Rompay, A R
2018-06-01
Assessment of ocular irritancy is an international regulatory requirement in the safety evaluation of industrial and consumer products. Although many in vitro ocular irritation assays exist, alone they are incapable of fully categorizing chemicals. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium was developed to assess the reliability of eight in vitro test methods and establish an optimal tiered-testing strategy. One assay selected was the Short Time Exposure (STE) assay. This assay measures the viability of SIRC rabbit corneal cells after 5min exposure to 5% and 0.05% solutions of test material, and is capable of categorizing of Category 1 and No Category chemicals. The accuracy of the STE test method to identify Cat 1 chemicals was 61.3% with 23.7% sensitivity and 95.2% specificity. If non-soluble chemicals and unqualified results were excluded, the performance to identify Cat 1 chemicals remained similar (accuracy 62.2% with 22.7% sensitivity and 100% specificity). The accuracy of the STE test method to identify No Cat chemicals was 72.5% with 66.2% sensitivity and 100% specificity. Excluding highly volatile chemicals, non-surfactant solids and non-qualified results resulted in an important improvement of the performance of the STE test method (accuracy 96.2% with 81.8% sensitivity and 100% specificity). Furthermore, it seems that solids are more difficult to test in the STE, 71.4% of the solids resulted in unqualified results (solubility issues and/or high variation between independent runs) whereas for liquids 13.2% of the results were not qualified, supporting the restriction of the test method regarding the testing of solids. Copyright © 2017. Published by Elsevier Ltd.
Validation of laboratory-scale recycling test method of paper PSA label products
Carl Houtman; Karen Scallon; Richard Oldack
2008-01-01
Starting with test methods and a specification developed by the U.S. Postal Service (USPS) Environmentally Benign Pressure Sensitive Adhesive Postage Stamp Program, a laboratory-scale test method and a specification were developed and validated for pressure-sensitive adhesive labels, By comparing results from this new test method and pilot-scale tests, which have been...
[A pseudo-outbreak of pharyngeal gonorrhoea related to a false-positive PCR-result].
Verzijl, A; Berretty, P J M; Erceg, A; Krekels, G A M; Van den Brule, A J C; Boel, C H E
2007-03-24
Nucleic acid amplification tests, including the polymerase chain reaction (PCR), are sensitive and specific tests that are often used for diagnosing sexually transmitted diseases (STDs). A pseudo-outbreak of pharyngeal gonorrhoea in a group of prostitutes turned out to have been caused by false-positive test results due to commensal oropharyngeal Neisseria species. Specific molecular tests may yield erroneous results. When the results of an STD study have major consequences at a legal or social level, it is advisable, in consultation with a medical microbiologist, to take a sample for culture or to carry out a second molecular test aimed at a different part of the bacterial genome.
On the Correlation of Specific Film Thickness and Gear Pitting Life
NASA Technical Reports Server (NTRS)
Krantz, Timothy Lewis
2014-01-01
The effect of the lubrication regime on gear performance has been recognized, qualitatively, for decades. Often the lubrication regime is characterized by the specific film thickness defined as the ratio of lubricant film thickness to the composite surface roughness. It can be difficult to combine results of studies to create a cohesive and comprehensive dataset. In this work gear surface fatigue lives for a wide range of specific film values were studied using tests done with common rigs, speeds, lubricant temperatures, and test procedures. This study includes previously reported data, results of an additional 50 tests, and detailed information from lab notes and tested gears. The dataset comprised 258 tests covering specific film values [0.47 to 5.2]. The experimentally determined surface fatigue lives, quantified as 10-percent life estimates, ranged from 8.7 to 86.8 million cycles. The trend is one of increasing life for increasing specific film. The trend is nonlinear. The observed trends were found to be in good agreement with data and recommended practice for gears and bearings. The results obtained will perhaps allow for the specific film parameter to be used with more confidence and precision to assess gear surface fatigue for purpose of design, rating, and technology development.
On the Correlation of Specific Film Thickness and Gear Pitting Life
NASA Technical Reports Server (NTRS)
Krantz, Timothy L.
2015-01-01
The effect of the lubrication regime on gear performance has been recognized, qualitatively, for decades. Often the lubrication regime is characterized by the specific film thickness defined as the ratio of lubricant film thickness to the composite surface roughness. It can be difficult to combine results of studies to create a cohesive and comprehensive dataset. In this work gear surface fatigue lives for a wide range of specific film values were studied using tests done with common rigs, speeds, lubricant temperatures, and test procedures. This study includes previously reported data, results of an additional 50 tests, and detailed information from lab notes and tested gears. The dataset comprised 258 tests covering specific film values (0.47 to 5.2). The experimentally determined surface fatigue lives, quantified as 10-percent life estimates, ranged from 8.7 to 86.8 million cycles. The trend is one of increasing life for increasing specific film. The trend is nonlinear. The observed trends were found to be in good agreement with data and recommended practice for gears and bearings. The results obtained will perhaps allow for the specific film parameter to be used with more confidence and precision to assess gear surface fatigue for purpose of design, rating, and technology development.
Serologic diagnosis of West Nile and St. Louis encephalitis virus infections in domestic chickens.
Patiris, Peter J; Oceguera, Leopoldo F; Peck, George W; Chiles, Robert E; Reisen, William K; Hanson, Carl V
2008-03-01
Adult domestic chickens were infected with West Nile virus (WNV) or St. Louis encephalitis virus (SLEV) and challenged with homologous or heterologous virus at 21 or 56 days postinfection (dpi). Sera were collected at selected time points after infection and assayed by enzyme immunoassay (EIA), plaque reduction neutralization test (PRNT), and a Western blot (WB) alternative to PRNT. EIA results were sensitive and accurate (few false positives) but not specific, requiring a confirmatory test to determine virus infection history. PRNT results generally were specific until challenge, after which test results were frequently equivocal and inadequate to determine first or second infecting virus. WB results confirmed the serologic cross-reactivity between WNV and SLEV envelope protein. Non-structural protein 1 and pre-membrane protein reactivities were highly specific for WNV during SLEV infection, but less specific for SLEV during WNV infection. WB and PRNT specificities were similar for both viruses from 6 to 14 dpi, and sensitivities to WNV were virtually identical.
Dlouha, Olga; Novak, Alexej; Vokral, Jan
2007-06-01
The aim of this project is to use central auditory tests for diagnosis of central auditory processing disorder (CAPD) in children with specific language impairment (SLI), in order to confirm relationship between speech-language impairment and central auditory processing. We attempted to establish special dichotic binaural tests in Czech language modified for younger children. Tests are based on behavioral audiometry using dichotic listening (different auditory stimuli that presented to each ear simultaneously). The experimental tasks consisted of three auditory measures (test 1-3)-dichotic listening of two-syllable words presented like binaural interaction tests. Children with SLI are unable to create simple sentences from two words that are heard separately but simultaneously. Results in our group of 90 pre-school children (6-7 years old) confirmed integration deficit and problems with quality of short-term memory. Average rate of success of children with specific language impairment was 56% in test 1, 64% in test 2 and 63% in test 3. Results of control group: 92% in test 1, 93% in test 2 and 92% in test 3 (p<0.001). Our results indicate the relationship between disorders of speech-language perception and central auditory processing disorders.
Pileggi, Claudia; Flotta, Domenico; Bianco, Aida; Nobile, Carmelo G A; Pavia, Maria
2014-07-01
Human-papillomavirus (HPV) DNA testing has been proposed as an alternative to primary cervical cancer screening using cytological testing. Review of the evidence shows that available data are conflicting for some aspects. The overall goal of the study is to update the performance of HPV DNA as stand-alone testing in primary cervical cancer screening, focusing particularly on the aspects related to the specificity profile of the HPV DNA testing in respect to cytology. We performed a meta-analysis of randomized controlled clinical trials. Eight articles were included in the meta-analysis. Three outcomes have been investigated: relative detection, relative specificity, and relative positive predictive value (PPV) of HPV DNA testing versus cytology. Overall evaluation of relative detection showed a significantly higher detection of CIN2+ and CIN3+ for HPV DNA testing versus cytology. Meta-analyses that considered all age groups showed a relative specificity that favored the cytology in detecting both CIN2+ and CIN3+ lesions whereas, in the ≥30 years' group, specificity of HPV DNA and cytology tests was similar in detecting both CIN2+ and CIN3+ lesions. Results of the pooled analysis on relative PPV showed a not significantly lower PPV of HPV DNA test over cytology. A main key finding of the study is that in women aged ≥30, has been found an almost overlapping specificity between the two screening tests in detecting CIN2 and above-grade lesions. Therefore, primary screening of cervical cancer by HPV DNA testing appears to offer the right balance between maximum detection of CIN2+ and adequate specificity, if performed in the age group ≥30 years. © 2013 UICC.
TESTS TO ASSESS SENSITIZATION TO ASPERGILLUS FUMIGATUS IN CYSTIC FIBROSIS
Aguiar, Simone Santana; Damaceno, Neiva; Forte, Wilma Carvalho Neves
2017-01-01
ABSTRACT Objective: To evaluate the results of the tests used to identify the IgE mediated sensitization to Aspergillus fumigatus in patients with cystic fibrosis. Methods: This is a cross-sectional descriptive study with a convenience sample of 86 patients diagnosed with cystic fibrosis in the Reference Service in Cystic Fibrosis at a tertiary teaching hospital. The following tests were performed to assess the sensitization to A. fumigatus in patients with cystic fibrosis: Total serum IgE, eosinophil count, fungus detection through oropharyngeal swab or sputum culture, serum-specific IgE, and immediate-type hypersensitivity (IgE) skin tests. We compared the results of the different tests performed. Results: In 33 (38.4%) patients with cystic fibrosis, with ages ranging from 1 to 33 years (median of 8 years), the IgE-mediated A. fumigatus sensitization test results were: in 16 patients, there was an increase in serum-specific IgE (>0.35 kU/L); in 23, skin tests were positive; and six had sensitization in both tests. We observed two patients with eosinophilia (>1,000 eosinophils/mm3) and seven with increasing total serum IgE (>1,000 IU/mL), all of whom obtained negative results in skin tests and had no IgE increase specific to A. fumigatus. A. fumigatus was not detected in oropharyngeal swabs and/or sputum culture of any patients. Conclusions: We conclude that, among the tests used to assess sensitization to A. fumigatus in cystic fibrosis patients, both serum-specific IgE and immediate-type hypersensitivity (IgE) skin tests are required. Serum eosinophilia and respiratory secretion culture were not essential in this study. PMID:28977288
Oral rapid test: an alternative to traditional HIV screening in Chile
Irarrazábal, Lisette Paola; Ferrer, Lilian; Cianelli, Rosina; Lara, Loreto; Reed, Reiley; Levy, Judith; Pérez, Carlos
2016-01-01
Objective To compare the sensitivity and specificity of an Oral Rapid Test (ORT) to that of the Enzyme-Linked Immunosorbent Assay (ELISA) for HIV testing in Santiago, Chile; to track the number of study participants returning for ELISA testing results; and to analyze the participants’ perceptions of the ORT compared to the ELISA. Methods A total of 497 people were recruited in Santiago, Chile: 153 had previously tested positive for HIV, and 344 were of unknown status. Participants were tested for HIV using both the ELISA and the ORT to examine and compare specificity and sensitivity. Qualitative data were collected from 22 participants to compare perceptions of the testing experience with ORT versus ELISA. Results The ELISA reported 184 (37%) of the 497 participants as being “positive” for HIV antibodies; the ORT showed 181 (36.4%) as being “reactive” for HIV. The ORT showed a sensitivity of 98.4% (95.7%–99.9%, 95% Confidence Interval) and specificity of 100%. The Kappa test produced K = 0.983 (P < 0.0001). Of the 344 participants whose HIV status was unknown at the start of the study, 55 failed to return for their ELISA results. Participants positively perceived ORT as having reduced both waiting time and anxiety over obtaining their test results. ORT oral swabbing appeared more practical and less invasive than drawing blood for the ELISA. Conclusions The ORT and ELISA were statistically equal in specificity and sensitivity. ORT provides quicker results, potentially ensuring that more people receive them, and does not require handling of or exposure to potentially hazardous blood products. PMID:23939368
... you have signs of an aspergillosis infection. Normal Results A normal test result means you do not ... meaning of your specific test results. What Abnormal Results Mean A positive result means antibodies to the ...
RUGE, H G; FROMM, G; FUHNER, F; GUINTO, R S
1960-01-01
In serological tests for syphilis, leprosy sera often give biologically false positive reactions. These may be due to the presence of non-specific elements-for example, the ubiquitous lipid antibodies-in the leprosy sera; or they may be the result of errors in technique or unfavourable working conditions in the laboratory. This paper presents the results of an investigation in which several hundred sera from lepers were submitted to four of the so-called "standard" serological tests for syphilis (STS), using either cardiolipin or crude lipid antigens; to a complement-fixation test using as antigen a suspension of Reiter treponemes (PR test); and to the Treponema pallidum immobilization (TPI) test. The investigation was carried out in a moderate climate and in technically well-equipped laboratories.It was found that the number of biologically false positive reactions was not as high as had been expected in the light of previous investigations. It was discovered, moreover, that it was the lipid antigens that were mainly responsible for the non-specific reactions, since both the PR and the TPI test showed a far greater specificity than any of the STS. But the TPI test, though highly specific, is also technically very complicated and therefore not suitable for use in regions where technical facilities are lacking. The authors consider that, in such regions, the simpler PR test will give sufficiently accurate results in the serodiagnosis of treponematoses. It must, however, be recognized that even the treponemal tests are not capable of differentiating between syphilis and yaws infections.
Diagnostic value of the basophil activation test in evaluating Hymenoptera venom sensitization.
Peternelj, Andreja; Silar, Mira; Bajrovic, Nissera; Adamic, Katja; Music, Ema; Kosnik, Mitja; Korosec, Peter
2009-01-01
Diagnosis of allergy to Hymenoptera venom is usually confirmed with skin testing and measurement of specific serum IgE antibody, tests which are sometimes inconclusive. In these cases, additional in vitro tests are necessary. The aim of this study was to show the applicability of the basophil activation test in detecting sensitization to Hymenoptera venom and to compare the test sensitivity and clinical positive-predictive value with skin prick tests and measurement of allergen-specific serum IgE. This prospective study was conducted between June 2004 and December 2007 and included a large group of 204 patients. All patients had a history of at least one systemic allergic reaction of Müller grades II-IV after a Hymenoptera sting. We compared results of the basophil activation test, specific serum IgE and skin prick tests with patients' clinical history and data on culprit insects. The overall clinical sensitivities of the basophil activation test, specific serum IgE and skin prick tests were 90%, 76% and 64%, respectively; the clinical positive-predictive values of the three tests were 79%, 73% and 78% for bee venom, 86%, 59% and 43% for wasp venom; and 84%, 77% and 22% for both venoms. Our results revealed a higher clinical sensitivity and comparable or better clinical positive-predictive value of basophil activation tests than skin prick tests and allergen-specific serum IgE in the detection of allergy to Hymenoptera venom.
Pakarinen, Harri; Flinkkilä, Tapio; Ohtonen, Pasi; Hyvönen, Pekka; Lakovaara, Martti; Leppilahti, Juhana; Ristiniemi, Jukka
2011-11-16
This study was designed to assess the sensitivity, specificity, and interobserver reliability of the hook test and the stress test for the intraoperative diagnosis of instability of the distal tibiofibular joint following fixation of ankle fractures resulting from supination-external rotation forces. We conducted a prospective study of 140 patients with an unstable unilateral ankle fracture resulting from a supination-external rotation mechanism (Lauge-Hansen SE). After internal fixation of the malleolar fracture, a hook test and an external rotation stress test under fluoroscopy were performed independently by the lead surgeon and assisting surgeon, followed by a standardized 7.5-Nm external rotation stress test of each ankle under fluoroscopy. A positive stress test result was defined as a side-to-side difference of >2 mm in the tibiotalar or the tibiofibular clear space on mortise radiographs. The sensitivity and specificity of each test were calculated with use of the standardized 7.5-Nm external rotation stress test as a reference. Twenty-four (17%) of the 140 patients had a positive standardized 7.5-Nm external rotation stress test after internal fixation of the malleolar fracture. The hook test had a sensitivity of 0.25 (95% confidence interval, 0.12 to 0.45) and a specificity of 0.98 (95% confidence interval, 0.94 to 1.0) for the detection of the same instabilities. The external rotation stress test had a sensitivity of 0.58 (95% confidence interval, 0.39 to 0.76) and a specificity of 0.96 (95% confidence interval, 0.90 to 0.98). Both tests had excellent interobserver reliability, with 99% agreement for the hook test and 98% for the stress test. Interobserver agreement for the hook test and the clinical stress test was excellent, but the sensitivity of these tests was insufficient to adequately detect instability of the syndesmosis intraoperatively.
... rule out a possible false-negative result. Normal Results A negative or nonreactive result means that you ... meaning of your specific test results. What Abnormal Results Mean A positive FTA-ABS is often a ...
[Comparison of Dengue viral nonstructural protein 1 antigen testing kits].
Wu, D; Zhao, L Z; Wu, Y H; Zhang, H; Zhang, M; Tan, Q Q; Zhou, H Q; Zhang, F C; He, J F
2018-02-06
Objective: To investigate the sensitivity and specificity of commercial nonstructural protein 1 (NS1) testing kits for Dengue fever diagnose, and provide the evidence for diagnostic criteria revision. Methods: 300 PCR or virus isolation positive blood samples for dengue virus were collected from sentinel hospitals for dengue surveillance in Guangzhou, Dongguang and Zhongshang from May 2015 to Nov. 2016. At the same time, 308 PCR negative samples for Dengue virus were collected as control group. The information of the sample was collected using questionnaires. These samples were tested using imported and domestic ELISA and the colloidal gold-labeled kits that were widely used for detecting dengue NS1. Sensitivity, specificity and coincidence were calculated and analyzed, and Z hongshan's result was regarded as the reslut of the third part. Results: The positive group includes 133 males and 167 females, average ages are 47.2±13.3, 179, 110 and 11 of them is Dengue Ⅰ, Ⅱ and Ⅲ respectively. The negative group includes 154 males and 154 females, average ages are (40.1±11.6) years old. The sensitivity of domestic ELISA Kits (94.5%) is less than imported (99.5%), and the result has statistical significance (χ(2)=8.59, P= 0.030), the specificity is 99.7% and 97.7% respectively; The sensitivity of imported and domestic the colloidal gold-labeled Kits is 97.5% and 96.5% respectively, both of specificities are 100%. The sensitivity and specificity of Dengue Ⅰ for NS1 test are more than 97.0%. The sensitivity of domestic ELISA and gold-labeled Kits is 90.0% and 95.0%, and the specificity is 96.8% and 100% respectively for Dengue Ⅱ test. The sensitivity of imported ELISA and gold-labeled Kits is 100% and 98.0%, and the specificity is 99.4% and 100% respectively for Dengue Ⅱ test. The result of the third party show the sensitivity and specificity of domestic ELISA and gold-labeled Kits are 90.0% and 98.0%, the differences has statistical significance (χ(2)=5.67, P= 0.020). Conclusion: NS1 testing can be used as early dengue fever diagnose for higher sensitivity and specificity.
NASA Technical Reports Server (NTRS)
Keegan, W. B.
1974-01-01
In order to produce cost effective environmental test programs, the test specifications must be realistic and to be useful, they must be available early in the life of a program. This paper describes a method for achieving such specifications for subsystems by utilizing the results of a statistical analysis of data acquired at subsystem mounting locations during system level environmental tests. The paper describes the details of this statistical analysis. The resultant recommended levels are a function of the subsystems' mounting location in the spacecraft. Methods of determining this mounting 'zone' are described. Recommendations are then made as to which of the various problem areas encountered should be pursued further.
End-of-fabrication CMOS process monitor
NASA Technical Reports Server (NTRS)
Buehler, M. G.; Allen, R. A.; Blaes, B. R.; Hannaman, D. J.; Lieneweg, U.; Lin, Y.-S.; Sayah, H. R.
1990-01-01
A set of test 'modules' for verifying the quality of a complementary metal oxide semiconductor (CMOS) process at the end of the wafer fabrication is documented. By electrical testing of specific structures, over thirty parameters are collected characterizing interconnects, dielectrics, contacts, transistors, and inverters. Each test module contains a specification of its purpose, the layout of the test structure, the test procedures, the data reduction algorithms, and exemplary results obtained from 3-, 2-, or 1.6-micrometer CMOS/bulk processes. The document is intended to establish standard process qualification procedures for Application Specific Integrated Circuits (ASIC's).
A formal protocol test procedure for the Survivable Adaptable Fiber Optic Embedded Network (SAFENET)
NASA Astrophysics Data System (ADS)
High, Wayne
1993-03-01
This thesis focuses upon a new method for verifying the correct operation of a complex, high speed fiber optic communication network. These networks are of growing importance to the military because of their increased connectivity, survivability, and reconfigurability. With the introduction and increased dependence on sophisticated software and protocols, it is essential that their operation be correct. Because of the speed and complexity of fiber optic networks being designed today, they are becoming increasingly difficult to test. Previously, testing was accomplished by application of conformance test methods which had little connection with an implementation's specification. The major goal of conformance testing is to ensure that the implementation of a profile is consistent with its specification. Formal specification is needed to ensure that the implementation performs its intended operations while exhibiting desirable behaviors. The new conformance test method presented is based upon the System of Communicating Machine model which uses a formal protocol specification to generate a test sequence. The major contribution of this thesis is the application of the System of Communicating Machine model to formal profile specifications of the Survivable Adaptable Fiber Optic Embedded Network (SAFENET) standard which results in the derivation of test sequences for a SAFENET profile. The results applying this new method to SAFENET's OSI and Lightweight profiles are presented.
Isaac, Beth M; Zucker, Jane R; Giancotti, Francesca R; Abernathy, Emily; Icenogle, Joseph; Rakeman, Jennifer L; Rosen, Jennifer B
2017-09-01
The New York City Department of Health and Mental Hygiene (DOHMH) receives clinical and laboratory reports for rubella. Because rubella immunoglobulin M (IgM) assays may produce false-positive results and rubella infections may be asymptomatic, interpretation of positive IgM results can be challenging. Rubella reports received by DOHMH in 2012 to 2013 were reviewed. The rubella IgM testing purpose was determined through case investigation. Results of IgM testing by indirect enzyme-linked immunosorbent assay (ELISA) and capture enzyme immunoassay (EIA) were compared to determine positive predictive value (PPV) and specificity. DOHMH received 199 rubella reports; 2 were true cases. Of all reports, 77.9% were tested for rubella IgM erroneously, 19.6% were tested for diagnostic purposes, 2.0% had unknown test purpose, and 0.5% were not tested. PPV of indirect ELISA was 6% overall, 14% for diagnostic tests, and 0% for tests ordered erroneously. PPV of capture EIA was 29% overall, 50% for diagnostic tests, and 0% for tests ordered erroneously. Overall, specificity was 52% for indirect ELISA and 85% for capture EIA. Limiting rubella IgM testing to patients for whom rubella diagnosis is suspected and using a more specific IgM assay have the potential to reduce false-positive rubella IgM results. Copyright © 2017 American Society for Microbiology.
40 CFR Appendix B to Part 60 - Performance Specifications
Code of Federal Regulations, 2014 CFR
2014-07-01
... 6216-98 is the reference for design specifications, manufacturer's performance specifications, and test... representative of a group of monitors produced during a specified period or lot, for conformance with the design... technique and a single analytical program are used. One Run may include results for more than one test...
Designing Medical Tests: The Other Side of Bayes' Theorem
ERIC Educational Resources Information Center
Ross, Andrew M.
2012-01-01
To compute the probability of having a disease, given a positive test result, is a standard probability problem. The sensitivity and specificity of the test must be given and the prevalence of the disease. We ask how a test-maker might determine the tradeoff between sensitivity and specificity. Adding hypothetical costs for detecting or failing to…
... every 3 or 6 months is recommended. Normal Results The following are the results when A1C is ... meaning of your specific test results. What Abnormal Results Mean An abnormal result means that you have ...
Garcia-Martinez, Irma; Weiss, Theresa R; Yousaf, Muhammad N; Ali, Ather; Mehal, Wajahat Z
2018-01-01
Leukocyte activation (LA) testing identifies food items that induce a patient specific cellular response in the immune system, and has recently been shown in a randomized double blinded prospective study to reduce symptoms in patients with irritable bowel syndrome (IBS). We hypothesized that test reactivity to particular food items, and the systemic immune response initiated by these food items, is due to the release of cellular DNA from blood immune cells. We tested this by quantifying total DNA concentration in the cellular supernatant of immune cells exposed to positive and negative foods from 20 healthy volunteers. To establish if the DNA release by positive samples is a specific phenomenon, we quantified myeloperoxidase (MPO) in cellular supernatants. We further assessed if a particular immune cell population (neutrophils, eosinophils, and basophils) was activated by the positive food items by flow cytometry analysis. To identify the signaling pathways that are required for DNA release we tested if specific inhibitors of key signaling pathways could block DNA release. Foods with a positive LA test result gave a higher supernatant DNA content when compared to foods with a negative result. This was specific as MPO levels were not increased by foods with a positive LA test. Protein kinase C (PKC) inhibitors resulted in inhibition of positive food stimulated DNA release. Positive foods resulted in CD63 levels greater than negative foods in eosinophils in 76.5% of tests. LA test identifies food items that result in release of DNA and activation of peripheral blood innate immune cells in a PKC dependent manner, suggesting that this LA test identifies food items that result in release of inflammatory markers and activation of innate immune cells. This may be the basis for the improvement in symptoms in IBS patients who followed an LA test guided diet.
Palmer, Christina G S; Boudreault, Patrick; Baldwin, Erin E; Sinsheimer, Janet S
2014-01-01
Using a prospective, longitudinal study design, this paper addresses the impact of genetic counseling and testing for deafness on deaf adults and the Deaf community. This study specifically evaluated the effect of genetic counseling and Connexin-26 and Connexin-30 genetic test results on participants' deaf identity and understanding of their genetic test results. Connexin-26 and Connexin-30 genetic testing was offered to participants in the context of linguistically and culturally appropriate genetic counseling. Questionnaire data collected from 209 deaf adults at four time points (baseline, immediately following pre-test genetic counseling, 1-month following genetic test result disclosure, and 6-months after result disclosure) were analyzed. Four deaf identity orientations (hearing, marginal, immersion, bicultural) were evaluated using subscales of the Deaf Identity Development Scale-Revised. We found evidence that participants understood their specific genetic test results following genetic counseling, but found no evidence of change in deaf identity based on genetic counseling or their genetic test results. This study demonstrated that culturally and linguistically appropriate genetic counseling can improve deaf clients' understanding of genetic test results, and the formation of deaf identity was not directly related to genetic counseling or Connexin-26 and Connexin-30 genetic test results.
40 CFR Appendix B to Part 60 - Performance Specifications
Code of Federal Regulations, 2012 CFR
2012-07-01
... manufacturers comply with a comprehensive series of design and performance specifications and test procedures to... must periodically select and test an opacity monitor, that is representative of a group of monitors... program are used. One Run may include results for more than one test condition. Constant emissions means...
40 CFR Appendix B to Part 60 - Performance Specifications
Code of Federal Regulations, 2011 CFR
2011-07-01
... manufacturers comply with a comprehensive series of design and performance specifications and test procedures to... must periodically select and test an opacity monitor, that is representative of a group of monitors... program are used. One Run may include results for more than one test condition. Constant emissions means...
40 CFR Appendix B to Part 60 - Performance Specifications
Code of Federal Regulations, 2013 CFR
2013-07-01
... manufacturers comply with a comprehensive series of design and performance specifications and test procedures to... must periodically select and test an opacity monitor, that is representative of a group of monitors... program are used. One Run may include results for more than one test condition. Constant emissions means...
Ebner, Matthias; Birschmann, Ingvild; Peter, Andreas; Härtig, Florian; Spencer, Charlotte; Kuhn, Joachim; Blumenstock, Gunnar; Zuern, Christine S; Ziemann, Ulf; Poli, Sven
2017-09-01
In patients receiving direct oral anticoagulants (DOACs), emergency treatment like thrombolysis for acute ischemic stroke is complicated by insufficient availability of DOAC-specific coagulation tests. Conflicting recommendations have been published concerning the use of global coagulation assays for ruling out relevant DOAC-induced anticoagulation. Four hundred eighty-one samples from 96 DOAC-treated patients were tested using prothrombin time (PT), activated partial thromboplastin time (aPTT) and thrombin time (TT), DOAC-specific assays (anti-Xa activity, diluted TT), and liquid chromatography-tandem mass spectrometry. Sensitivity and specificity of test results to identify DOAC concentrations <30 ng/mL were calculated. Receiver operating characteristic analyses were used to define reagent-specific cutoff values. Normal PT and aPTT provide insufficient specificity to safely identify DOAC concentrations <30 ng/mL (rivaroxaban/PT: specificity, 77%/sensitivity, 94%; apixaban/PT: specificity, 13%/sensitivity, 94%, dabigatran/aPTT: specificity, 49%/sensitivity, 91%). Normal TT was 100% specific for dabigatran, but sensitivity was 26%. In contrast, reagent-specific PT and aPTT cutoffs provided >95% specificity and a specific TT cutoff enhanced sensitivity for dabigatran to 84%. For apixaban, no cutoffs could be established. Even if highly DOAC-reactive reagents are used, normal results of global coagulation tests are not suited to guide emergency treatment: whereas normal PT and aPTT lack specificity to rule out DOAC-induced anticoagulation, the low sensitivity of normal TT excludes the majority of eligible patients from treatment. However, reagent-specific cutoffs for global coagulation tests ensure high specificity and optimize sensitivity for safe emergency decision making in rivaroxaban- and dabigatran-treated patients. URL: http://www.clinicaltrials.gov. Unique identifiers: NCT02371044 and NCT02371070. © 2017 American Heart Association, Inc.
Banko, A V; Lazarević, I B; Cupić, M D; Knezević, A M; Stevanović, G D; Krejović-Trivić, S B; Jovanović, T P
2009-01-01
Routine laboratory diagnosis of infectious mononucleosis is based on EBV serological testing, but due to problems in interpretation of results, molecular methods, especially PCR, are often necessary. The aim of the present study was to investigate correlation between results of PCR and specific serological tests in diagnosis of Epstein-Barr virus in patients with mononucleosis syndrome. The study comprised 68 patients with mononucleosis syndrome. Their blood samples were tested using ELISA for detection of 4 EBV specific antibodies (anti-VCA IgM and IgG, anti-EA-D IgG and anti-EBNA-1 IgG) and PCR for detection of EBV DNA. According to results of serology 42 patients had acute primary infection, 2 reactivation, 1 chronic active infection, 19 past infection, and 4 have been EBV seronegative. EBV DNA was detected in 17 patients (25%) and all of them were serologically defined as acutely infected. PCR was useful for resolving unclear serology results. Specific serology is the first step in diagnosis of IM, but PCR may serve as a useful additional diagnostic tool for clarifying serological dilemmas, reaching final diagnosis and defining status of the infection.
Paglialonga, Alessia; Tognola, Gabriella; Grandori, Ferdinando
2014-09-01
A novel, user-operated test of suprathreshold acuity in noise for use in adult hearing screening (AHS) was developed. The Speech Understanding in Noise test (SUN) is a speech-in-noise test that makes use of a list of vowel-consonant-vowel (VCV) stimuli in background noise presented in a three-alternative forced choice (3AFC) paradigm by means of a touch sensitive screen. The test is automated, easy-to-use, and provides self-explanatory results (i.e., 'no hearing difficulties', or 'a hearing check would be advisable', or 'a hearing check is recommended'). The test was developed from its building blocks (VCVs and speech-shaped noise) through two main steps: (i) development of the test list through equalization of the intelligibility of test stimuli across the set and (ii) optimization of the test results through maximization of the test sensitivity and specificity. The test had 82.9% sensitivity and 85.9% specificity compared to conventional pure-tone screening, and 83.8% sensitivity and 83.9% specificity to identify individuals with disabling hearing impairment. Results obtained so far showed that the test could be easily performed by adults and older adults in less than one minute per ear and that its results were not influenced by ambient noise (up to 65dBA), suggesting that the test might be a viable method for AHS in clinical as well as non-clinical settings. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Smith, V.
2000-11-01
This report documents the development of analytical techniques required for interpreting and comparing space systems electromagnetic interference test data with commercial electromagnetic interference test data using NASA Specification SSP 30237A "Space Systems Electromagnetic Emission and Susceptibility Requirements for Electromagnetic Compatibility." The PSpice computer simulation results and the laboratory measurements for the test setups under study compare well. The study results, however, indicate that the transfer function required to translate test results of one setup to another is highly dependent on cables and their actual layout in the test setup. Since cables are equipment specific and are not specified in the test standards, developing a transfer function that would cover all cable types (random, twisted, or coaxial), sizes (gauge number and length), and layouts (distance from the ground plane) is not practical.
NASA Technical Reports Server (NTRS)
Smith, V.; Minor, J. L. (Technical Monitor)
2000-01-01
This report documents the development of analytical techniques required for interpreting and comparing space systems electromagnetic interference test data with commercial electromagnetic interference test data using NASA Specification SSP 30237A "Space Systems Electromagnetic Emission and Susceptibility Requirements for Electromagnetic Compatibility." The PSpice computer simulation results and the laboratory measurements for the test setups under study compare well. The study results, however, indicate that the transfer function required to translate test results of one setup to another is highly dependent on cables and their actual layout in the test setup. Since cables are equipment specific and are not specified in the test standards, developing a transfer function that would cover all cable types (random, twisted, or coaxial), sizes (gauge number and length), and layouts (distance from the ground plane) is not practical.
Bethlehem, Simone; Bexley, Jennifer; Mueller, Ralf S
2012-02-15
Adverse food reaction (AFR) is a common differential diagnosis for pruritic dogs. The only way to diagnose AFR is an elimination diet of 6-8 weeks with a protein and a carbohydrate source not previously fed. In humans, patch testing has been shown to be a useful tool to diagnose food allergies. In veterinary medicine, serum food allergen-specific antibody testing is widely offered to identify suitable ingredients for such diets. The aim of this study was to determine sensitivity, specificity, negative and positive predictability of patch testing with and serum antibody testing for a variety of common food stuffs. Twenty-five allergic dogs underwent an elimination diet and individual rechallenge with selected food stuffs, food patch testing and serum testing for food-antigen specific IgE and IgG. Eleven clinically normal control dogs only were subjected to patch and serum testing. The sensitivity and specificity of the patch test were 96.7 and 89.0% respectively, negative and positive predictability were 99.3 and 63.0%. For IgE and IgG the sensitivity was 6.7 and 26.7%, specificity were 91.4 and 88.3%, the negative predictive values 80.7 and 83.7% and the positive predictive values were 15.4 and 34.8%. Based on these results, a positive reaction of a dog on these tests is not very helpful, but a negative result indicates that this antigen is tolerated well. We conclude that patch testing (and to a lesser degree serum testing) can be helpful in choosing ingredients for an elimination diet in a dog with suspected AFR. Copyright © 2012. Published by Elsevier B.V.
Li, Jing-Jing; Gao, Qi; Liu, Zhi-Dong; Kang, Qiong-Hua; Hou, Yi-Jun; Zhang, Luo-Chuan; Hu, Xiao-Mei; Li, Jie; Zhang, Juan
2015-01-01
Internal quality control (IQC) is a critical component of laboratory quality management, and IQC products can determine the reliability of testing results. In China, given the fact that most blood transfusion compatibility laboratories do not employ IQC products or do so minimally, there is a lack of uniform and standardized IQC methods. To explore the reliability of IQC products and methods, we studied 697 results from IQC samples in our laboratory from 2012 to 2014. The results showed that the sensitivity and specificity of the IQCs in anti-B testing were 100% and 99.7%, respectively. The sensitivity and specificity of the IQCs in forward blood typing, anti-A testing, irregular antibody screening, and cross-matching were all 100%. The reliability analysis indicated that 97% of anti-B testing results were at a 99% confidence level, and 99.9% of forward blood typing, anti-A testing, irregular antibody screening, and cross-matching results were at a 99% confidence level. Therefore, our IQC products and methods are highly sensitive, specific, and reliable. Our study paves the way for the establishment of a uniform and standardized IQC method for pre-transfusion compatibility testing in China and other parts of the world. PMID:26488582
[Penicillin allergy as a diagnostic problem. Overview and personal studies].
Walker, T; Jung, E G; Bayerl, C
2000-11-01
Penicillin allergy is a common clinical problem. The distinction between penicillin and para-infectious exanthems is difficult. We investigated the reliability of the history, as well as the sensitivity and specificity of skin tests and specific IgE levels. 160 patients with a history of penicillin allergy were retrospectively evaluated in the outpatient department of a dermatological clinic. Nearly 50% were diagnosed as allergic to penicillin by detection of specific IgE or skin test. About 60% of the patients with immediate type reactions, and 72% with maculo-papular erythema showed positive reactions in skin tests. Significantly more patients were diagnosed as allergic to penicillin by intradermal testing than by prick testing (p < 0.05). The sensitivity of the specific IgE RAST was 17.9%; the specifity, 89.5%. For the prick test the sensitivity was 8.2%; the specificity 90.8%. For the intradermal test the sensitivity was 26%; the specifity 69.7%. We suggest a step by step procedure to detect penicillin allergy making the diagnostic results as valid as possible.
Incompleteness of Bluetooth protocol conformance test cases
NASA Astrophysics Data System (ADS)
Wu, Peng; Gao, Qiang
2001-10-01
This paper describes a formal method to verify the completeness of conformance testing, in which not only Implementation Under Test (IUT) is formalized in SDL, but also conformance tester is described in SDL so that conformance testing can be performed in simulator provided with CASE tool. The protocol set considered is Bluetooth, an open wireless communication technology. Our research results show that Bluetooth conformance test specification is not complete in that it has only limited coverage and many important capabilities defined in Bluetooth core specification are not tested. We also give a detail report on the missing test cases against Bluetooth core specification, and provide a guide on further test case generation in the future.
Evaluation of central auditory processing in children with Specific Language Impairment.
Włodarczyk, Elżbieta; Szkiełkowska, Agata; Piłka, Adam; Skarżyński, Henryk
2015-01-01
Specific Language Impairment (SLI) affects about 7-15 % of children of school age and according to the currently accepted diagnostic criteria, it is presumed that these children do not suffer from hearing impairment. The goal of this work was to assess anomalies of central auditory processes in a group of children diagnosed with specific language impairment. Material consisted of 200 children aged 7-10 years (100 children in the study group and 100 hundred in the control group). Selected psychoacoustic tests (Frequency Pattern Test - FPT, Duration Pattern Test - DPT, Dichotic Digit Test - DDT, Time Compressed Sentence Test - CST, Gap Detection Test - GDT) were performed in all children. Results were subject to statistical analysis. It was observed that mean results obtained in individual age groups in the study group are significantly lower than in the control group. Based on the conducted studies we may conclude that children with SLI suffer from disorders of some higher auditory functions, which substantiates the diagnosis of hearing disorders according to the AHSA (American Hearing and Speech Association) guidelines. Use of sound-based, not verbal tests, eliminates the probability that observed problems with perception involve only perception of speech, therefore do not signify central hearing disorders, but problems with understanding of speech. Lack of literature data on the significance of FPT, DPT, DDT, CST and GDT tests in children with specific language impairment precludes comparison of acquired results and makes them unique.
How does creating a concept map affect item-specific encoding?
Grimaldi, Phillip J; Poston, Laurel; Karpicke, Jeffrey D
2015-07-01
Concept mapping has become a popular learning tool. However, the processes underlying the task are poorly understood. In the present study, we examined the effect of creating a concept map on the processing of item-specific information. In 2 experiments, subjects learned categorized or ad hoc word lists by making pleasantness ratings, sorting words into categories, or creating a concept map. Memory was tested using a free recall test and a recognition memory test, which is considered to be especially sensitive to item-specific processing. Typically, tasks that promote item-specific processing enhance free recall of categorized lists, relative to category sorting. Concept mapping resulted in lower recall performance than both the pleasantness rating and category sorting condition for categorized words. Moreover, concept mapping resulted in lower recognition memory performance than the other 2 tasks. These results converge on the conclusion that creating a concept map disrupts the processing of item-specific information. (c) 2015 APA, all rights reserved.
Robyn, M; Priyono, W B; Kim, L M; Brum, E
2012-06-01
A study was conducted to assess the diagnostic sensitivity and specificity of a disease surveillance method for diagnosis of highly pathogenic avian influenza (HPAI) outbreaks in household chicken flocks used by participatory disease surveillance (PDS) teams in Yogyakarta Province, Indonesia. The Government of Indonesia, in partnership with the Food and Agriculture Organization of the United Nations, has implemented a PDS method for the detection of HPAI outbreaks in poultry since 2006. The PDS method in Indonesia utilizes both a clinical case definition (CD) and the result of a commercial rapid antigen test kit Yogyakarta 55611, to diagnose HPAI outbreaks, primarily in backyard chicken flocks. The following diagnostic sensitivities and specificities were obtained relative to real-time reverse transcription-PCR as the gold standard diagnostic test: 1) 89% sensitivity (CI95: 75%-97%) and 96% specificity (CI95: 89%-99%) for the PDS CD alone; 2) 86% sensitivity (CI95: 71%-95%) and 99% specificity (CI95: 94%-100%) for the rapid antigen test alone; and 3) 84% sensitivity (CI95: 68%-94%) and 100% specificity (CI95: 96%-100%) for the PDS CD result combined with the rapid antigen test result. Based on these results, HPAI outbreaks in extensively raised household chickens can be diagnosed with sufficient sensitivity and specificity using the PDS method as implemented in Indonesia. Subject to further field evaluation, data from this study suggest that the diagnostic sensitivity of the PDS method may be improved by expanding the PDS CD to include more possible clinical presentations of HPAI and by increasing the number of rapid antigen tests to three different birds with HPAI-compatible signs of same flock.
Deletion of Fmr1 results in sex-specific changes in behavior.
Nolan, Suzanne O; Reynolds, Conner D; Smith, Gregory D; Holley, Andrew J; Escobar, Brianna; Chandler, Matthew A; Volquardsen, Megan; Jefferson, Taylor; Pandian, Ashvini; Smith, Tileena; Huebschman, Jessica; Lugo, Joaquin N
2017-10-01
In this study, we used a systemic Fmr1 knockout in order to investigate both genotype- and sex-specific differences across multiple measures of sociability, repetitive behaviors, activity levels, anxiety, and fear-related learning and memory. Fragile X syndrome is the most common monogenic cause of intellectual disability and autism. Few studies to date have examined sex differences in a mouse model of Fragile X syndrome, though clinical data support the idea of differences in both overall prevalence and phenotype between the sexes. Using wild-type and systemic homozygous Fmr1 knockout mice, we assessed a variety of behavioral paradigms in adult animals, including the open field test, elevated plus maze, nose-poke assay, accelerating rotarod, social partition task, three-chambered social task, and two different fear conditioning paradigms. Tests were ordered such that the most invasive tests were performed last in the sequence, and testing paradigms for similar behaviors were performed in separate cohorts to minimize testing effects. Our results indicate several sex-specific changes in Fmr1 knockout mice, including male-specific increases in activity levels, and female-specific increases in repetitive behaviors on both the nose-poke assay and motor coordination on the accelerating rotarod task. The results also indicated that Fmr1 deletion results in deficits in fear learning and memory across both sexes, and no changes in social behavior across two tasks. These findings highlight the importance of including female subjects in preclinical studies, as simply studying the impact of genetic mutations in males does not yield a complete picture of the phenotype. Further research should explore these marked phenotypic differences among the sexes. Moreover, given that treatment strategies are typically equivalent between the sexes, the results highlight a potential need for sex-specific therapeutics.
Tamaro, Giorgio; Donato, Michela; Princi, Tanja; Parco, Sergio
2009-04-01
A symptom-based diagnosis of infectious mononucleosis is not sufficiently accurate, since some clinical symptoms of infectious mononucleosis are also detected in other virally induced diseases. Moreover, not all patients suffering from infectious mononucleosis show circulating atypical lymphocytes, which are considered characteristic of this disease. Therefore, when this disorder is suspected, serum analyses are carried out to detect the presence of certain immunoglobulins associated with infectious mononucleosis in the patient's blood. The aim of this study was to evaluate the sensitivity and the specificity of a rapid test detecting heterophil antibodies in diagnosing infectious mononucleosis in a paediatric population. We considered 163 paediatric patients with suspected infectious mononucleosis and we tested their serums to detect heterophil antibodies (using an inexpensive and rapid test) and specific immunoglobulins directed against Epstein-Barr virus (EBV) (these assays are known to be characterized by high sensitivity and specificity, but are more expensive and time-consuming). By comparing the results of the rapid test with those of the other assays, we found that the sensitivity of the first test was 61.8%, whereas its specificity was sufficiently high (about 90%). We show that, in paediatric patients, the detection of heterophil antibodies is not a very sensitive test, therefore the determination of immunoglobulins against specific antigens of EBV is recommended.
... such as HIV/AIDS or hepatitis C. Normal Results Normal fetal blood sample results are: Normal pH: ... meaning of your specific test results. What Abnormal Results Mean A fetal scalp blood pH level of ...
[Increase in orders for specific IgE tests and more positive results in children in 1985-2003].
Baatenburg de Jong, A; Dikkeschei, L D; Brand, P L P
2008-08-09
To describe changes over time in the number of allergy tests for specific IgE ordered and outcomes in children, to help address the question whether the increase in allergies is due to an actual increase in sensitisation or an increase in diagnostic awareness of allergies among physicians. Retrospective and descriptive. We reviewed the results of all specific IgE tests performed in our hospital's laboratory for children 0-18 years of age in the period 1985-2003. This included tests ordered by both general practitioners and hospital-based specialists. We analysed trends over time in the number of tests ordered (as an indicator ofdiagnostic awareness) and test results (as an indicator ofsensitisation). Between 1989 and 1995, the annual number of tests ordered increased from 1 per 10,000 children to 95 per 10,000 children and remained stable thereafter. Before 1990, more than 90% of tests were ordered by hospital-based specialists; after 1990, approximately 70% of the tests were ordered by general practitioners (p < 0.001). The proportion of positive tests remained stable at approximately 27% until 1991, after which it increased to more than 45% (p < 0.001). The increase in the proportion of positive tests suggests an increase in atopic sensitization between 1985 and 2000 which has stabilized since.
Axisymmetric Strain Path Tests on Nellis Baseline Sand
1986-09-01
tested to determine their grain-size distributions, specific gravities , and Atterberg limits. The results of these tests are su-Arized in Table 2.1...plastic limits, plasticity index, and specific gravity . All four batches of NB sand were classified by the Unified Soil Classi- fication System...those contaminated by oil due to membrane leakage. Based on these data and a specific gravity of 2.62, values of dry density, void ratio, degree of
van Wagenberg, Coen P A; Backus, Gé B C; Wisselink, Henk J; van der Vorst, Jack G A J; Urlings, Bert A P
2013-09-01
In this paper we analyze the impact of the sensitivity and specificity of a Mycobacterium avium (Ma) test on pig producer incentives to control Ma in finishing pigs. A possible Ma control system which includes a serodiagnostic test and a penalty on finishing pigs in herds detected with Ma infection was modelled. Using a dynamic optimization model and a grid search of deliveries of herds from pig producers to slaughterhouse, optimal control measures for pig producers and optimal penalty values for deliveries with increased Ma risk were identified for different sensitivity and specificity values. Results showed that higher sensitivity and lower specificity induced use of more intense control measures and resulted in higher pig producer costs and lower Ma seroprevalence. The minimal penalty value needed to comply with a threshold for Ma seroprevalence in finishing pigs at slaughter was lower at higher sensitivity and lower specificity. With imperfect specificity a larger sample size decreased pig producer incentives to control Ma seroprevalence, because the higher number of false positives resulted in an increased probability of rejecting a batch of finishing pigs irrespective of whether the pig producer applied control measures. We conclude that test sensitivity and specificity must be considered in incentive system design to induce pig producers to control Ma in finishing pigs with minimum negative effects. Copyright © 2013 Elsevier B.V. All rights reserved.
... or monitor many types of kidney diseases. Normal Results For adults, normal urine sodium values are generally ... meaning of your specific test result. What Abnormal Results Mean A higher than normal urine sodium level ...
40 CFR 53.50 - General provisions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the specific tests that must be carried out and the test results, evidence, documentation, and other... specifications set forth in appendix L or O, respectively, of part 50 of this chapter as well as additional requirements specified in this subpart E. Some or all of these tests may also be applicable to a candidate...
Xu, Lan; Verdoodt, Freija; Wentzensen, Nicolas; Bergeron, Christine; Arbyn, Marc
2015-01-01
Background Women with a cytological diagnosis of atypical squamous cells, cannot exclude high-grade squamous intraepithelial lesion (ASC-H) are usually immediately referred to colposcopy. However, triage may reduce the burden of diagnostic work-up and avoid over-treatment. Methods A meta-analysis was conducted to assess the accuracy of hrHPV testing, and testing for other molecular markers to detect CIN of grade II or III or worse (CIN2+ or CIN3+) in women with ASC-H. An additional question assessed was whether triage is useful given the relatively high pre-triage probability of underlying precancer. Results The pooled absolute sensitivity and specificity for CIN2+ of HC2 (derived from 19 studies) was 93% (95% CI: 89–95%) and 45% (95% CI: 41–50%), respectively. The p16INK4a staining (only 3 studies) has similar sensitivity (93%, 95% CI:75–100%) but superior specificity (specificity ratio: 1.69) to HC2 for CIN2+. Testing for PAX1 gene methylation (only 1 study) showed a superior specificity of 95% (specificity ratio: 2.08). The average pre-test risk was 34% for CIN2+ and 20% for CIN3+. A negative HC2 result decreased this to 8% and 5%, whereas a positive result upgraded the risk to 47% and 28%. Conclusions Due to the high probability of precancer in ASC-H, the utility of triage is limited. The usual recommendation to refer women with ASC-H to colposcopy is not altered by a positive triage test, whatever the test used. A negative hrHPV DNA or p16INK4a test may allow for repeat testing but this recommendation will depend on local decision thresholds for referral. PMID:26618614
Which Fecal Immunochemical Test Should I Choose?
Daly, Jeanette M.; Xu, Yinghui; Levy, Barcey T.
2017-01-01
Objectives: To summarize the fecal immunochemical tests (FITs) available in the United States, the 2014 pathology proficiency testing (PT) program FIT results, and the literature related to the test characteristics of FITs available in the United States to detect advanced adenomatous polyps (AAP) and/or colorectal cancer (CRC). Methods: Detailed review of the Food and Drug Administration’s Clinical Laboratory Improvement Amendments (CLIA) database of fecal occult blood tests, the 2014 FIT PT program results, and the literature related to FIT accuracy. Results: A search of the CLIA database identified 65 FITs, with 26 FITs available for purchase in the United States. Thirteen of these FITs were evaluated on a regular basis by PT programs, with an overall sensitivity of 99.1% and specificity of 99.2% for samples spiked with hemoglobin. Automated FITs had better sensitivity and specificity than CLIA-waived FITs for detection of AAP and CRC in human studies using colonoscopy as the gold standard. Conclusion: Although many FITs are available in the United States, few have been tested in proficiency testing programs. Even fewer have data in humans on sensitivity and specificity for AAP or CRC. Our review indicates that automated FITs have the best test characteristics for AAP and CRC. PMID:28447866
Testing the effects of social anxiety disorder on friendship quality across gender and ethnicity.
Rodebaugh, Thomas L; Fernandez, Katya C; Levinson, Cheri A
2012-01-01
Previous research suggests that social anxiety disorder (SAD) has a specific relationship with impairment in friendship quality; however, potential moderators of this relationship have not been tested. The current study examines whether the specific effect of SAD on friendship quality is stable or varies across gender and ethnicity in a large epidemiological dataset. Results indicate that the underlying construct of friendship quality differed slightly but significantly between men and women; as a result, effects of SAD were tested in men and women separately. After partially constraining friendship quality across ethnic groups, our results indicated that the relationship between SAD and friendship quality remained robust in all groups. In addition to replicating the finding that SAD specifically relates to perceived friendship quality, the current study highlights the need to test whether underlying constructs such as friendship quality are consistent across the groups that make up heterogeneous samples.
Comparison of Six Automated Treponema-Specific Antibody Assays.
Park, Borae G; Yoon, Jihoon G; Rim, John Hoon; Lee, Anna; Kim, Hyon-Suk
2016-01-01
Six different Treponema (TP)-specific immunoassays were compared to the fluorescent treponemal antibody absorption (FTA-ABS) test. A total of 615 samples were tested. The overall percent agreement, analytical sensitivity, and analytical specificity of each assay compared to the FTA-ABS test were as follows: Architect Syphilis TP, 99.2%, 96.8%, and 100%; Cobas Syphilis, 99.8%, 99.4%, and 100%; ADVIA Centaur Syphilis, 99.8%, 99.4%, and 100%; HISCL Anti-TP assay kit, 99.7%, 98.7%, and 100%; Immunoticles Auto3 TP, 99.0%, 97.5%, and 99.6%; Mediace TPLA, 98.0%, 98.1%, and 98.0%. All results that were discrepant between the TP-specific assays were associated with samples from noninfectious cases (11 immunoassay false positives and 7 from previous syphilis cases). Our study demonstrated that TP-specific immunoassays generally showed high sensitivities, specificities, and percentages of agreement compared to FTA-ABS, with rare cases of false-positive or false-negative results. Therefore, most TP-specific immunoassays are acceptable for use in screening for syphilis. However, it is important to perform a thorough review of a patient's clinical and treatment history for interpreting the results of syphilis serology. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
[Efficiency and specificity of the KAT-test for rapid diagnosis of falciparum malaria].
Cong, Le Dinh; Sergiev, V P; Rabinovich, S A; Nhah, Doan Hanh; Huong, Nguyen Van; Morozov, E N; Kukina, I V; Thinh, Ta Thi; Maksakovskaia, E V; Dao, Le Minh; Chalyĭ, V F; To, Dang Thi; Fandeev, V A; Hoa, Ngo Viet; Due, Nguyen Thi
2002-01-01
A new rapid KAT Quick Malaria test for the diagnosis of falciparum malaria, which is based on the detection of a monoclonal antibody-antigen complex of malaria parasites, has been worked out by the KAT Medical CC in South Africa. The efficiency and specificity of the KAT test were compared with those of the microscopic method and with the ICT test for rapid diagnosis of P. falciparum and P. vivax. The polymerase chain reaction was used as a control test. Testing for malaria was performed on 98 blood samples from feverish patients in Vietnam and Tadjikistan and among the persons who had returned to Moscow from endemic regions. The efficiency of the KAT test for falciparum-malaria was found to be 100% versus 90.5% with ICT. The absence of cross-reactions with P. vivax and the presence of pseudopositive results of the KAT test for fever cases of non-malaria origin indicate its high specificity. There was no correlation between the rate of test line colouring and the level of parasitemia. The KAT test yielded positive results only when gametocytes were found in blood specimens.
Evaluation of Gamma Interferon and Antibody Tuberculosis Tests in Alpacas
Holder, Tom; Clifford, Derek; Dexter, Ian; Brewer, Jacky; Smith, Noel; Waring, Laura; Crawshaw, Tim; Gillgan, Steve; Lyashchenko, Konstantin; Lawrence, John; Clarke, John; de la Rua-Domenech, Ricardo; Vordermeier, Martin
2012-01-01
We describe the performance of cell-based and antibody blood tests for the antemortem diagnosis of tuberculosis (TB) in South American camelids (SAC). The sensitivity and specificity of the gamma interferon (IFN-γ) release assay, two lateral flow rapid antibody tests (Stat-Pak and Dual Path Platform [DPP]), and two enzyme-linked immunosorbent assay (ELISA)-based antibody tests (Idexx and Enferplex) were determined using diseased alpacas from Mycobacterium bovis culture-confirmed breakdown herds and TB-free alpacas from geographical areas with no history of bovine TB, respectively. Our results show that while the sensitivities of the IFN-γ and antibody tests were similar (range of 57.7% to 66.7%), the specificity of the IFN-γ test (89.1%) was lower than those of any of the antibody tests (range of 96.4% to 97.4%). This lower specificity of the IFN-γ test was at least in part due to undisclosed Mycobacterium microti infection in the TB-free cohort, which stimulates a positive purified protein derivative (PPD) response. The sensitivity of infection detection could be increased by combining two antibody tests, but even the use of all four antibody tests failed to detect all diseased alpacas. These antibody-negative alpacas were IFN-γ positive. We found that the maximum sensitivity could be achieved only by the combination of the IFN-γ test with two antibody tests in a “test package,” although this resulted in decreased specificity. The data from this evaluation of tests with defined sensitivity and specificity provide potential options for antemortem screening of SAC for TB in herd breakdown situations and could also find application in movement testing and tracing investigations. PMID:22914362
Evaluation of gamma interferon and antibody tuberculosis tests in alpacas.
Rhodes, Shelley; Holder, Tom; Clifford, Derek; Dexter, Ian; Brewer, Jacky; Smith, Noel; Waring, Laura; Crawshaw, Tim; Gillgan, Steve; Lyashchenko, Konstantin; Lawrence, John; Clarke, John; de la Rua-Domenech, Ricardo; Vordermeier, Martin
2012-10-01
We describe the performance of cell-based and antibody blood tests for the antemortem diagnosis of tuberculosis (TB) in South American camelids (SAC). The sensitivity and specificity of the gamma interferon (IFN-γ) release assay, two lateral flow rapid antibody tests (Stat-Pak and Dual Path Platform [DPP]), and two enzyme-linked immunosorbent assay (ELISA)-based antibody tests (Idexx and Enferplex) were determined using diseased alpacas from Mycobacterium bovis culture-confirmed breakdown herds and TB-free alpacas from geographical areas with no history of bovine TB, respectively. Our results show that while the sensitivities of the IFN-γ and antibody tests were similar (range of 57.7% to 66.7%), the specificity of the IFN-γ test (89.1%) was lower than those of any of the antibody tests (range of 96.4% to 97.4%). This lower specificity of the IFN-γ test was at least in part due to undisclosed Mycobacterium microti infection in the TB-free cohort, which stimulates a positive purified protein derivative (PPD) response. The sensitivity of infection detection could be increased by combining two antibody tests, but even the use of all four antibody tests failed to detect all diseased alpacas. These antibody-negative alpacas were IFN-γ positive. We found that the maximum sensitivity could be achieved only by the combination of the IFN-γ test with two antibody tests in a "test package," although this resulted in decreased specificity. The data from this evaluation of tests with defined sensitivity and specificity provide potential options for antemortem screening of SAC for TB in herd breakdown situations and could also find application in movement testing and tracing investigations.
ERIC Educational Resources Information Center
Nelson, Jason M.; Lindstrom, Will; Foels, Patricia A.
2015-01-01
Test anxiety and its correlates were examined with college students with and without specific reading disability (RD; n = 50 in each group). Results indicated that college students with RD reported higher test anxiety than did those without RD, and the magnitude of these differences was in the medium range on two test anxiety scales. Relative to…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wohlgemuth, John; Silverman, Timothy; Miller, David C.
This paper describes an effort to inspect and evaluate PV modules in order to determine what failure or degradation modes are occurring in field installations. This paper will report on the results of six site visits, including the Sacramento Municipal Utility District (SMUD) Hedge Array, Tucson Electric Power (TEP) Springerville, Central Florida Utility, Florida Solar Energy Center (FSEC), the TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been usedmore » to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification. TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification. TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification.« less
Palmer, Christina G. S.; Boudreault, Patrick; Baldwin, Erin E.; Sinsheimer, Janet S.
2014-01-01
Using a prospective, longitudinal study design, this paper addresses the impact of genetic counseling and testing for deafness on deaf adults and the Deaf community. This study specifically evaluated the effect of genetic counseling and Connexin-26 and Connexin-30 genetic test results on participants' deaf identity and understanding of their genetic test results. Connexin-26 and Connexin-30 genetic testing was offered to participants in the context of linguistically and culturally appropriate genetic counseling. Questionnaire data collected from 209 deaf adults at four time points (baseline, immediately following pre-test genetic counseling, 1-month following genetic test result disclosure, and 6-months after result disclosure) were analyzed. Four deaf identity orientations (hearing, marginal, immersion, bicultural) were evaluated using subscales of the Deaf Identity Development Scale-Revised. We found evidence that participants understood their specific genetic test results following genetic counseling, but found no evidence of change in deaf identity based on genetic counseling or their genetic test results. This study demonstrated that culturally and linguistically appropriate genetic counseling can improve deaf clients' understanding of genetic test results, and the formation of deaf identity was not directly related to genetic counseling or Connexin-26 and Connexin-30 genetic test results. PMID:25375116
ERIC Educational Resources Information Center
Ivancevich, John M.
1976-01-01
A behaviorally specific motivational effort rating scale was developed and tested. The organizational specific scale results were examined and compared to those generated from the Landy and Guion scale. It was found that the organizationally specific and engineer relevant scale is a better predictor of two types of expectancies. (Author)
Development of a high-specific-speed centrifugal compressor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rodgers, C.
1997-07-01
This paper describes the development of a subscale single-stage centrifugal compressor with a dimensionless specific speed (Ns) of 1.8, originally designed for full-size application as a high volume flow, low pressure ratio, gas booster compressor. The specific stage is noteworthy in that it provides a benchmark representing the performance potential of very high-specific-speed compressors, of which limited information is found in the open literature. Stage and component test performance characteristics are presented together with traverse results at the impeller exit. Traverse test results were compared with recent CFD computational predictions for an exploratory analytical calibration of a very high-specific-speed impellermore » geometry. The tested subscale (0.583) compressor essentially satisfied design performance expectations with an overall stage efficiency of 74% including, excessive exit casing losses. It was estimated that stage efficiency could be increased to 81% with exit casing losses halved.« less
Halling, V W; Jones, M F; Bestrom, J E; Wold, A D; Rosenblatt, J E; Smith, T F; Cockerill, F R
1999-10-01
Recently, a treponema-specific immunoglobulin G (IgG) enzyme immunoassay (EIA), the CAPTIA Syphilis-G (Trinity Biotech, Jamestown, N.Y.), has become available as a diagnostic test for syphilis. A total of 89 stored sera previously tested by the fluorescent treponemal antibody absorption (FTA-ABS) IgG assay were evaluated by the CAPTIA EIA. The FTA-ABS IgG procedure was performed by technologists unblinded to results of rapid plasmid reagin (RPR) testing of the same specimens. Borderline CAPTIA-positive samples (antibody indices of >/=0.650 and =0.900) were retested; if the second analysis produced an index of >0.900, the sample was considered positive. Thirteen of 89 (15%) samples had discrepant results. Compared to the FTA-ABS assay, the CAPTIA EIA had a sensitivity and specificity and positive and negative predictive values of 70.7, 97.9, 96.7, and 79.7%, respectively. In another analysis, discrepancies between results were resolved by repeated FTA-ABS testing (technologists were blinded to previous RPR results) and patient chart reviews. Seven CAPTIA-negative samples which were previously interpreted (unblinded) as minimally reactive by the FTA method were subsequently interpreted (blinded) as nonreactive. One other discrepant sample (CAPTIA negative and FTA-ABS positive [at an intensity of 3+], unblinded) was FTA negative with repeated testing (blinded). For the five remaining discrepant samples, chart reviews indicated that one patient (CAPTIA negative and FTA-ABS positive [minimally reactive], blinded) had possible syphilis. These five samples were also evaluated and found to be negative by another treponema-specific test, the Treponema pallidum microhemagglutination assay. Therefore, after repeated testing and chart reviews, 2 of the 89 (2%) samples had discrepant results; the adjusted sensitivity, specificity, and positive and negative predictive values were 96.7, 98.3, 96.7, and 98.3%, respectively. This study demonstrates that the CAPTIA IgG EIA is a reliable method for syphilis testing and that personnel performing tests which require subjective interpretation, like the FTA-ABS test, may be biased by RPR test results.
Halling, V. W.; Jones, M. F.; Bestrom, J. E.; Wold, A. D.; Rosenblatt, J. E.; Smith, T. F.; Cockerill, F. R.
1999-01-01
Recently, a treponema-specific immunoglobulin G (IgG) enzyme immunoassay (EIA), the CAPTIA Syphilis-G (Trinity Biotech, Jamestown, N.Y.), has become available as a diagnostic test for syphilis. A total of 89 stored sera previously tested by the fluorescent treponemal antibody absorption (FTA-ABS) IgG assay were evaluated by the CAPTIA EIA. The FTA-ABS IgG procedure was performed by technologists unblinded to results of rapid plasmid reagin (RPR) testing of the same specimens. Borderline CAPTIA-positive samples (antibody indices of ≥0.650 and ≤0.900) were retested; if the second analysis produced an index of >0.900, the sample was considered positive. Thirteen of 89 (15%) samples had discrepant results. Compared to the FTA-ABS assay, the CAPTIA EIA had a sensitivity and specificity and positive and negative predictive values of 70.7, 97.9, 96.7, and 79.7%, respectively. In another analysis, discrepancies between results were resolved by repeated FTA-ABS testing (technologists were blinded to previous RPR results) and patient chart reviews. Seven CAPTIA-negative samples which were previously interpreted (unblinded) as minimally reactive by the FTA method were subsequently interpreted (blinded) as nonreactive. One other discrepant sample (CAPTIA negative and FTA-ABS positive [at an intensity of 3+], unblinded) was FTA negative with repeated testing (blinded). For the five remaining discrepant samples, chart reviews indicated that one patient (CAPTIA negative and FTA-ABS positive [minimally reactive], blinded) had possible syphilis. These five samples were also evaluated and found to be negative by another treponema-specific test, the Treponema pallidum microhemagglutination assay. Therefore, after repeated testing and chart reviews, 2 of the 89 (2%) samples had discrepant results; the adjusted sensitivity, specificity, and positive and negative predictive values were 96.7, 98.3, 96.7, and 98.3%, respectively. This study demonstrates that the CAPTIA IgG EIA is a reliable method for syphilis testing and that personnel performing tests which require subjective interpretation, like the FTA-ABS test, may be biased by RPR test results. PMID:10488183
Miller, Shelley A; Hindler, Janet A; Chengcuenca, Angelo; Humphries, Romney M
2017-06-01
Carbapenemase-producing Enterobacteriaceae (CPE) are a significant threat to public health. In 2015, CDC revised the surveillance definition for CPE to include all Enterobacteriaceae resistant to any carbapenem tested. However, this definition is associated with poor specificity. We evaluated the performance of this definition, compared to carbapenemase PCR, for a collection of 125 Enterobacteriaceae We also investigated the impact of ancillary testing for carbapenemase of isolates that met the CDC CPE surveillance definition. The two ancillary tests evaluated were the Xpert Carba-R assay, a molecular test, and the carbapenem inactivation method (CIM). Two variables were evaluated for the CIM: suspension of organisms in double-distilled water (ddH 2 O) versus tryptic soy broth (TSB) to incubate disks, and incubation of plates for 6 h versus 18 to 20 h. The sensitivity and specificity of the Carba-R assay were 100% compared to the results of in-house PCR. The sensitivities of the CIM performed with TSB were 94.6% when read at 6 h and 97.7% when read at 18 to 20 h; the sensitivities with ddH 2 O were 88.0% when read at 6 h and 93.0% when incubated for 18 to 20 h. The specificity was 100% for all variables tested. Without ancillary testing, the sensitivity of the CDC definition was 98.9% for CPE, and the specificity was 6.1%. Testing isolates that screened positive by the CDC definition with the Xpert Carba-R did not change the sensitivity, and it improved the specificity to 100%. Similarly, the use of the CIM (TSB and 18 to 20 h of incubation) to confirm screen-positive isolates resulted in a sensitivity of 95.6% and specificity of 100%. Copyright © 2017 American Society for Microbiology.
Koblavi-Dème, Stéphania; Maurice, Chantal; Yavo, Daniel; Sibailly, Toussaint S.; N′guessan, Kabran; Kamelan-Tano, Yvonne; Wiktor, Stefan Z.; Roels, Thierry H.; Chorba, Terence; Nkengasong, John N.
2001-01-01
To evaluate serologic testing algorithms for human immunodeficiency virus (HIV) based on a combination of rapid assays among persons with HIV-1 (non-B subtypes) infection, HIV-2 infection, and HIV-1–HIV-2 dual infections in Abidjan, Ivory Coast, a total of 1,216 sera with known HIV serologic status were used to evaluate the sensitivity and specificity of four rapid assays: Determine HIV-1/2, Capillus HIV-1/HIV-2, HIV-SPOT, and Genie II HIV-1/HIV-2. Two serum panels obtained from patients recently infected with HIV-1 subtypes B and non-B were also included. Based on sensitivity and specificity, three of the four rapid assays were evaluated prospectively in parallel (serum samples tested by two simultaneous rapid assays) and serial (serum samples tested by two consecutive rapid assays) testing algorithms. All assays were 100% sensitive, and specificities ranged from 99.4 to 100%. In the prospective evaluation, both the parallel and serial algorithms were 100% sensitive and specific. Our results suggest that rapid assays have high sensitivity and specificity and, when used in parallel or serial testing algorithms, yield results similar to those of enzyme-linked immunosorbent assay-based testing strategies. HIV serodiagnosis based on rapid assays may be a valuable alternative in implementing HIV prevention and surveillance programs in areas where sophisticated laboratories are difficult to establish. PMID:11325995
Horng, Yu-Tze; Soo, Po-Chi; Shen, Bin-Jon; Hung, Yu-Li; Lo, Kai-Yin; Su, Hsun-Pi; Wei, Jun-Rong; Hsieh, Shang-Chen; Hsueh, Po-Ren; Lai, Hsin-Chih
2006-06-01
A novelly improved polymerase chian reaction and immunochromatography test (PCR-ICT) hybrid assay comprising traditional multiplex-nested PCR and ICT, (a lateral-flow device) was developed for direct detection of Legionella bacteria from environmental cooling tower samples. The partial 16S rDNA (specific for Legionella spp.) and dnaJ (specific for Legionella pneumophila) genes from Legionella chromosome were first specifically amplified by multiplex-nested PCR, respectively, followed by detection using ICT strip. Reading of results was based on presence or absence of the two test lines on the strips. Presence of test line 1 indicated existence of Legionella spp. specific 16S rDNA and identified Legionella spp. Presence of test line 2 further indicated existence of dnaJ and thus specifically identified L. pneumophila. In contrast, for non-Legionellae bacteria no test line formation was observed. Results of direct detection of Legionella bacteria and L. pneumophila from water tower specimens by this assay showed 100% sensitivity, and 96.6% and 100% specificity, respectively compared with traditional culture, biochemical and serological identification methods. The PCR-ICT hybrid assay does not require sophisticated equipment and was proved to be practically useful in rapid and direct Legionellae detection from environmental water samples.
Qiao, H-L; Liu, J-H; Yang, J; Dong, Z-M
2005-08-01
The aim of this study was to investigate the relationships between skin test, specific immunoglobulin (Ig) E and cytokines in penicillin allergy. We collected the sera of 259 patients with historical positive skin test to penicillins, with immediate positive skin test and with a negative skin test results. The positive rate of specific IgE antibodies in 259 patients was 62.2% (161) by using radioallergosorbent test (RAST). Of the eight kinds of antigenic determinants, the positive rates of specific IgE to major and minor determinants were 43.63% (113) and 52.51% (136), respectively (p < 0.05). In 122 patients with immediate positive skin test, when the degrees of skin test were +, 2+, 3+ and 4+, the positive rates of specific IgE were 45.7, 57.1, 85.2 and 100%, respectively. The levels of interleukin (IL)-4, IL-13 and interferon (IFN)-gamma in the sera of patients with positive skin test were significantly increased with the degree of positive skin test (p < 0.05). The combined use of major and minor determinants in RAST offers the better test for the detection of penicillin-specific IgE antibodies. IL-4, IL-13 and IFN-gamma play important roles in penicillin allergy.
"We'll call you when the results are in": Preferences for how medical test results are delivered.
Dooley, Michael D; Burreal, Shay; Sweeny, Kate
2017-02-01
Whether healthy or sick, adults undergo frequent medical testing; however, no guidelines currently exist as to how patients are informed of their medical test results. This short report provides an initial look at how healthcare professionals deliver medical test results and patient preferences regarding these procedures. We specifically focus on two options for delivery of results: (1) open-ended timing, in which patients are contacted without warning when test results become available; or (2) closed-ended timing, in which patients are provided with a specific day and time when they will learn their test results. Participants who underwent a recent medical test indicated which delivery method their healthcare professional provided and their preferred method. Findings demonstrate a large discrepancy between actual and preferred timing, stemming from a general trend towards providing open-ended timing, whereas patient preferences were evenly split between the two options. This study provides a first step in understanding the merits of two options for delivering medical test results to patients and suggests an opportunity to improve patient care. The findings from this study provide first steps toward the development of guidelines for delivering test results in ways that maximize the quality of patient care. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Colle, Livia; Baron-Cohen, Simon; Hill, Jacqueline
2007-04-01
Children with autism have delays in the development of theory of mind. However, the sub-group of children with autism who have little or no language have gone untested since false belief tests (FB) typically involve language. FB understanding has been reported to be intact in children with specific language impairment (SLI). This raises the possibility that a non-verbal FB test would distinguish children with autism vs. children with SLI. The present study tested two predictions: (1) FB understanding is to some extent independent of language ability; and (2) Children with autism with low language levels show specific impairment in theory of mind. Results confirmed both predictions. Results are discussed in terms of the role of language in the development of mindreading.
40 CFR 1065.720 - Liquefied petroleum gas.
Code of Federal Regulations, 2014 CFR
2014-07-01
... CONTROLS ENGINE-TESTING PROCEDURES Engine Fluids, Test Fuels, Analytical Gases and Other Calibration....720—Test Fuel Specifications for Liquefied Petroleum Gas Property Value Reference procedure 1 Propane... methods yield different results, use the results from ASTM D1267. 3 The test fuel must not yield a...
Prediction of obeche wood-induced asthma by specific skin prick testing.
Hannu, T; Lindström, I; Palmroos, P; Kuuliala, O; Sauni, R
2013-09-01
It has previously been shown that a positive skin prick test (SPT) result is a good predictor of a positive specific inhalation challenge (SIC) in patients with occupational asthma (OA) related to wheat or rye flours. This association has not been previously studied in OA attributable to obeche wood. To describe a clinical series of patients with OA induced by obeche wood. To investigate if the SPT result can be used as a predictor for the outcome of SIC tests. OA was diagnosed according to patient history, lung function examinations and SIC tests, as well as the determination of obeche SPTs. We analysed sensitivity, specificity and positive (PPV) and negative predictive values (NPV) at different wheal sizes of the SPTs and drew receiver-operating characteristic plots using the SIC test result as the gold standard. Obeche wood SIC tests were performed on 34 symptomatic workers. Of these, 27 workers had a positive test result and were diagnosed as having OA. The minimal cut-off value with a PPV of 100% was an SPT wheal of 3.5 mm from obeche wood. This means that all workers with a wheal size of ≥ 3.5 mm from obeche wood had a positive SIC. Positive SPT results in symptomatic workers were good predictors of a positive SIC. SIC with obeche wood may be unnecessary in strongly sensitized workers.
Tribble, David R.; Baqar, Shahida; Pang, Lorrin W.; Mason, Carl; Houng, Huo-Shu H.; Pitarangsi, Chittima; Lebron, Carlos; Armstrong, Adam; Sethabutr, Orntipa; Sanders, John W.
2008-01-01
High rates of Campylobacter fluoroquinolone resistance highlight the need to evaluate diagnostic strategies that can be used to assist with clinical management. Diagnostic tests were evaluated with U.S. soldiers presenting with acute diarrhea during deployment in Thailand. The results of bedside and field laboratory diagnostic tests were compared to stool microbiology findings for 182 enrolled patients. Campylobacter jejuni was isolated from 62% of the cases. Clinical and laboratory findings at the time of presentation were evaluated to determine their impact on the posttest probability, defined as the likelihood of a diagnosis of Campylobacter infection. Clinical findings, the results of tests for inflammation (stool occult blood testing [Hemoccult], fecal leukocytes, fecal lactoferrin, plasma C-reactive protein), and the numbers of Campylobacter-specific antibody-secreting cells in peripheral blood failed to increase the posttest probability above 90% in this setting of Campylobacter hyperendemicity when these findings were present. Positive results by a Campylobacter-specific commercial enzyme immunoassay (EIA) and, less so, a research PCR were strong positive predictors. The negative predictive value for ruling out Campylobacter infection, defined as a posttest probability of less than 10%, was similarly observed with these Campylobacter-specific stool-based tests as well the fecal leukocyte test. Compared to the other tests evaluated, the Campylobacter EIA is a sensitive and specific rapid diagnostic test that may assist with diagnostic evaluation, with consideration of the epidemiological setting, logistics, and cost. PMID:18234869
Test results and description of a 1-kW free-piston Stirling engine with a dashpot load
NASA Technical Reports Server (NTRS)
Schreiber, J.
1983-01-01
A 1 kW (1.33 hp) single cylinder free piston Stirling engine was installed in the test facilities at the Lewis laboratory. The engine was designed specifically for research of the dynamics of its operation. A more complete description of the engine and its instrumentation is provided in a prior NASA paper TM-82999 by J. G. Schreiber. Initial tests at Lewis showed the power level and efficiency of the engine to be below design level. Tests were performed to help determine the specific problems in the engine causing the below design level performance. Modifications to engine hardware and to the facility where performed in an effort to bring the power output and efficiency to their design values. As finally configured the engine generated more than 1250 watts of output power at an engine efficiency greater than 32 percent. This report presents the tests performed to help determine the specific problems, the results if the problem was eliminated, the fix performed to the hardware, and the test results after the engine was tested. In cases where the fix did not cause the anticipated effects, a possible explanation is given.
Distribution of indoor radon concentrations in Pennsylvania, 1990-2007
Gross, Eliza L.
2013-01-01
Median indoor radon concentrations aggregated according to geologic units and hydrogeologic settings are useful for drawing general conclusions about the occurrence of indoor radon in specific geologic units and hydrogeologic settings, but the associated data and maps have limitations. The aggregated indoor radon data have testing and spatial accuracy limitations due to lack of available information regarding testing conditions and the imprecision of geocoded test locations. In addition, the associated data describing geologic units and hydrogeologic settings have spatial and interpretation accuracy limitations, which are a result of using statewide data to define conditions at test locations and geologic data that represent a broad interpretation of geologic units across the State. As a result, indoor air radon concentration distributions are not proposed for use in predicting individual concentrations at specific sites nor for use as a decision-making tool for property owners to decide whether to test for indoor radon concentrations at specific property locations.
Variation of a test's sensitivity and specificity with disease prevalence.
Leeflang, Mariska M G; Rutjes, Anne W S; Reitsma, Johannes B; Hooft, Lotty; Bossuyt, Patrick M M
2013-08-06
Anecdotal evidence suggests that the sensitivity and specificity of a diagnostic test may vary with disease prevalence. Our objective was to investigate the associations between disease prevalence and test sensitivity and specificity using studies of diagnostic accuracy. We used data from 23 meta-analyses, each of which included 10-39 studies (416 total). The median prevalence per review ranged from 1% to 77%. We evaluated the effects of prevalence on sensitivity and specificity using a bivariate random-effects model for each meta-analysis, with prevalence as a covariate. We estimated the overall effect of prevalence by pooling the effects using the inverse variance method. Within a given review, a change in prevalence from the lowest to highest value resulted in a corresponding change in sensitivity or specificity from 0 to 40 percentage points. This effect was statistically significant (p < 0.05) for either sensitivity or specificity in 8 meta-analyses (35%). Overall, specificity tended to be lower with higher disease prevalence; there was no such systematic effect for sensitivity. The sensitivity and specificity of a test often vary with disease prevalence; this effect is likely to be the result of mechanisms, such as patient spectrum, that affect prevalence, sensitivity and specificity. Because it may be difficult to identify such mechanisms, clinicians should use prevalence as a guide when selecting studies that most closely match their situation.
Vitkova, O N; Kapustina, T P; Mikhailova, V V; Safonov, G A; Vlasova, N N; Belousova, R V
2015-01-01
The goal of this work was to demonstrate the results of the development of the enzyme-linked immunosorbent tests with chemiluminescence detection and colorimetric detection of specific viral antigens and antibodies for identifying the avian influenza and the Newcastle disease viruses: high sensitivity and specificity of the immuno- chemiluminescence assay, which are 10-50 times higher than those of the ELISA colorimetric method. The high effectiveness of the results and the automation of the process of laboratory testing (using a luminometer) allow these methods to be recommended for including in primary screening tests for these infectious diseases.
Laboratory test methods for evaluating the fire response of aerospace materials
NASA Technical Reports Server (NTRS)
Hilado, C. J.
1979-01-01
The test methods which were developed or evaluated were intended to serve as means of comparing materials on the basis of specific responses under specific sets of test conditions, using apparatus, facilities, and personnel that would be within the capabilities of perhaps the majority of laboratories. Priority was given to test methods which showed promise of addressing the pre-ignition state of a potential fire. These test methods were intended to indicate which materials may present more hazard than others under specific test conditions. These test methods are discussed and arranged according to the stage of a fire to which they are most relevant. Some observations of material performance which resulted from this work are also discussed.
Variation of a test’s sensitivity and specificity with disease prevalence
Leeflang, Mariska M.G.; Rutjes, Anne W.S.; Reitsma, Johannes B.; Hooft, Lotty; Bossuyt, Patrick M.M.
2013-01-01
Background: Anecdotal evidence suggests that the sensitivity and specificity of a diagnostic test may vary with disease prevalence. Our objective was to investigate the associations between disease prevalence and test sensitivity and specificity using studies of diagnostic accuracy. Methods: We used data from 23 meta-analyses, each of which included 10–39 studies (416 total). The median prevalence per review ranged from 1% to 77%. We evaluated the effects of prevalence on sensitivity and specificity using a bivariate random-effects model for each meta-analysis, with prevalence as a covariate. We estimated the overall effect of prevalence by pooling the effects using the inverse variance method. Results: Within a given review, a change in prevalence from the lowest to highest value resulted in a corresponding change in sensitivity or specificity from 0 to 40 percentage points. This effect was statistically significant (p < 0.05) for either sensitivity or specificity in 8 meta-analyses (35%). Overall, specificity tended to be lower with higher disease prevalence; there was no such systematic effect for sensitivity. Interpretation: The sensitivity and specificity of a test often vary with disease prevalence; this effect is likely to be the result of mechanisms, such as patient spectrum, that affect prevalence, sensitivity and specificity. Because it may be difficult to identify such mechanisms, clinicians should use prevalence as a guide when selecting studies that most closely match their situation. PMID:23798453
Burgos, Joaquin; Hernández-Losa, Javier; Landolfi, Stefania; Guelar, Ana; Dinares, MªCarmen; Villar, Judith; Navarro, Jordi; Ribera, Esteve; Falcó, Vicenç; Curran, Adria
2017-10-23
To assess the oncogenic human papillomavirus (HPV) determination and the cotesting HPV and anal cytology value to detect high-grade anal intraepithelial neoplasia (HGAIN) in a cohort of HIV-MSM. Prospective study of HIV-infected MSM who underwent screening for anal dysplasia. Screening program includes anal cytology, HPV testing, and high-resolution anoscopy (HRA) at each visit. Histological samples were obtained if suspicious lesions were revealed by HRA. Sensitivity and specificity of the different tests were calculated by using histological results of HRA-guided biopsy as the reference test for HGAIN diagnosis. From May 2009 to August 2016, 692 HIV-infected MSM underwent 1827 anal cytologies, 1841 HRA examinations, and 1607 HPV testing. At first screening visit, anal cytology results were abnormal in 418 (60.4%) of 692 patients, and oncogenic HPV genotypes were found in 482 (79.5%) of 606 patients. Anal cytology showed a sensitivity of 89.2% [95% confidence interval (CI); 80.7-94.2] and a specificity of 44.2% (95% CI; 40.2-48.2) to detect HGAIN. Oncogenic HPV testing had 90.4% sensitivity (95% CI; 82-86.8) and 24.4% specificity (95% CI; 20.8-28.3). Cotesting showed a 97.4% sensitivity (95% CI; 91-99.3) and 14% specificity (95% CI; 11.2-17.3). In patients with atypical squamous cells of uncertain significance on cytology, oncogenic HPV testing had 91.3% sensitivity and 28.3% specificity to detect HGAIN. Abnormal cytology and oncogenic HPV determination showed similar sensitivity for detecting HGAIN. The two tests used together improved the sensitivity but with lowered specificity. In our opinion, HPV testing does not improve HGAIN detection and should not replace anal cytology as a standard screening test for HIV-infected MSM.
Refining the structure and content of clinical genomic reports.
Dorschner, Michael O; Amendola, Laura M; Shirts, Brian H; Kiedrowski, Lesli; Salama, Joseph; Gordon, Adam S; Fullerton, Stephanie M; Tarczy-Hornoch, Peter; Byers, Peter H; Jarvik, Gail P
2014-03-01
To effectively articulate the results of exome and genome sequencing we refined the structure and content of molecular test reports. To communicate results of a randomized control trial aimed at the evaluation of exome sequencing for clinical medicine, we developed a structured narrative report. With feedback from genetics and non-genetics professionals, we developed separate indication-specific and incidental findings reports. Standard test report elements were supplemented with research study-specific language, which highlighted the limitations of exome sequencing and provided detailed, structured results, and interpretations. The report format we developed to communicate research results can easily be transformed for clinical use by removal of research-specific statements and disclaimers. The development of clinical reports for exome sequencing has shown that accurate and open communication between the clinician and laboratory is ideally an ongoing process to address the increasing complexity of molecular genetic testing. © 2014 Wiley Periodicals, Inc.
Refining the Structure and Content of Clinical Genomic Reports
DORSCHNER, MICHAEL O.; AMENDOLA, LAURA M.; SHIRTS, BRIAN H.; KIEDROWSKI, LESLI; SALAMA, JOSEPH; GORDON, ADAM S.; FULLERTON, STEPHANIE M.; TARCZY-HORNOCH, PETER; BYERS, PETER H.; JARVIK, GAIL P.
2014-01-01
To effectively articulate the results of exome and genome sequencing we refined the structure and content of molecular test reports. To communicate results of a randomized control trial aimed at the evaluation of exome sequencing for clinical medicine, we developed a structured narrative report. With feedback from genetics and non-genetics professionals, we developed separate indication-specific and incidental findings reports. Standard test report elements were supplemented with research study-specific language, which highlighted the limitations of exome sequencing and provided detailed, structured results, and interpretations. The report format we developed to communicate research results can easily be transformed for clinical use by removal of research-specific statements and disclaimers. The development of clinical reports for exome sequencing has shown that accurate and open communication between the clinician and laboratory is ideally an ongoing process to address the increasing complexity of molecular genetic testing. PMID:24616401
NASA Astrophysics Data System (ADS)
Fan, Yu-Jen; Maruyama, Ken; Ayothi, Ramakrishnan; Naruoka, Takehiko; Chakraborty, Tonmoy; Ashworth, Dominic; Chun, Jun Sung; Montgomery, Cecilia; Jen, Shih-Hui; Neisser, Mark; Cummings, Kevin
2015-03-01
In this paper, we present the first results of witness sample based outgas resist family test to improve the efficiency of outgas testing using EUV resists that have shown proven imaging performance. The concept of resist family testing is to characterize the boundary conditions of outgassing scale from three major components for each resist family. This achievement can significantly reduce the cost and improve the resist outgas learning cycle. We also report the imaging performance and outgas test results of state of the art resists and discuss the consequence of the resist development with recent change of resist outgassing specifications. Three chemically amplified resists selected from higher outgassing materials are investigated, but no significant improvement in resist performance is observed.
... hours. Normal value ranges may vary slightly from one lab to another. Some labs use different measurements or test different samples. Talk to your provider about the meaning of your specific test results. What Abnormal Results Mean An increased level of urinary delta-ALA may ...
Griffiths, Rebecca L M; El-Shanawany, Tariq; Jolles, Stephen R A; Selwood, Clive; Heaps, Adrian G; Carne, Emily M; Williams, Paul E
2017-01-01
Allergy is diagnosed from typical symptoms, and tests are performed to incriminate the suspected precipitant. Skin prick tests (SPTs) are commonly performed, inexpensive, and give immediate results. Laboratory tests (ImmunoCAP) for serum allergen-specific IgE antibodies are usually performed more selectively. The immuno-solid phase allergen chip (ISAC) enables testing for specific IgE against multiple allergen components in a multiplex assay. We retrospectively analysed clinic letters, case notes, and laboratory results of 118 patients attending the National Adult Allergy Service at the University Hospital of Wales who presented diagnostic difficulty, to evaluate which testing strategy (SPT, ImmunoCAP, or ISAC) was the most appropriate to use to confirm the diagnosis in these complex patients, evaluated in a "real-life" clinical service setting. In patients with nut allergy, the detection rates of SPTs (56%) and ISAC (65%) were lower than those of ImmunoCAP (71%). ISAC had a higher detection rate (88%) than ImmunoCAP (69%) or SPT (33%) in the diagnosis of oral allergy syndrome. ImmunoCAP test results identified all 9 patients with anaphylaxis due to wheat allergy (100%), whereas ISAC was positive in only 6 of these 9 (67%). In this difficult diagnostic group, the ImmunoCAP test should be the preferred single test for possible allergy to nuts, wheat, other specific foods, and anaphylaxis of any cause. In these conditions, SPT and ISAC tests give comparable results. The most useful single test for oral allergy syndrome is ISAC, and SPT should be the preferred test for latex allergy. © 2017 S. Karger AG, Basel.
Comparison of five diagnostic tests for Giardia duodenalis in fecal samples from young dogs.
Uehlinger, Fabienne D; Naqvi, S Ali; Greenwood, Spencer J; McClure, J Trenton; Conboy, Gary; O'Handley, Ryan; Barkema, Herman W
2017-09-15
Five diagnostic tests were compared for the diagnosis of Giardia duodenalis in fecal samples of young dogs. Fecal samples were collected from 136 healthy dogs <1year old and examined using immunofluorescence antibody microscopy (IFA) after sucrose gradient centrifugation, zinc sulfate centrifugal flotation technique (ZSCT), SNAP ® Giardia test, and ProSpecT ® Giardia EZ Microplate assay. In addition, polymerase chain reaction (PCR) of the 16S rRNA gene was performed. Kappa (κ) statistic was calculated to assess diagnostic agreement between the IFA and each test. Using the IFA as the gold standard, the relative sensitivity and specificity of each test were determined. Subsequently, a Bayesian approach was used to estimate the sensitivity and specificity of each test in comparison to the IFA results. Giardia duodenalis was detected in 41% of the samples examined by IFA. The ZSCT resulted in 37% of positive samples, with a relative sensitivity and specificity of 86 and 98%, respectively. The SNAP ® Giardia test was positive in 40% of the samples, with a relative sensitivity and specificity of 91 and 96%, respectively. The ProSpecT ® test was positive in 51% of the samples, with a relative sensitivity and specificity of 100 and 83%, respectively. The relative sensitivity and specificity for PCR were 58 and 56%, respectively, with 55% of samples being PCR-positive. While the sensitivity and specificity estimates of each test in comparison to the IFA changed when using a Bayesian approach, the conclusions remained the same. While the ProSpecT ® test was the most sensitive test in this study, it is not designed for dogs and more costly than the other tests. The SNAP ® Giardia test performed similar to the ZSCT but may be more favorable because it is fast and easy to perform. Performance of the PCR was poor and the benefit of PCR may be in determining genotypes for evaluating zoonotic transfer between dogs and humans. Copyright © 2017 Elsevier B.V. All rights reserved.
Wainstein, Brynn Kevin; Yee, Anthony; Jelley, Donna; Ziegler, Mary; Ziegler, John B
2007-05-01
Previous studies have suggested various diagnostic cut-offs of allergy tests for the diagnosis of clinical peanut allergy in children. There are few data relating to the use of combinations of these tests in children. We aimed to determine the validity of previously reported diagnostic cut-off levels of peanut allergen skin tests and peanut specific-immunoglobulin (Ig) E, as well as the usefulness of combinations of these, for predicting clinical peanut allergy in our Allergy Clinic. Children attending the Allergy Clinic with a positive peanut skin prick test (SPT; n = 84) were included in the study. Immediate skin application food tests (I-SAFT) using 1 g of peanut butter (positive if any wheals were detected at 15 min), peanut specific-IgE levels and open-label peanut food challenges were performed. Fifty-two of 85 peanut challenges were positive. Skin prick test specificity was 67% at >or=8 mm and 100% at >or=15 mm. The I-SAFT was 82% specific. A peanut specific-IgE level of 0.37 kU/l was 98% sensitive but 33% specific. A level of 10 kU/l was 100% specific. Combinations of a SPT of >or=8 mm with a positive I-SAFT and a peanut specific-IgE >or=0.37 kU/l were 88% specific with a sensitivity of 38%. Using challenge outcomes as the standard, available in vitro and in vivo diagnostic tests for peanut allergy have poor sensitivity and specificity and combining them does not significantly improve their clinical usefulness. Previously described diagnostic cut-off levels do not have general applicability. Allergy practitioners may need to interpret results of allergy tests in the context of their own practices.
Safety and clinical performance of acoustic reflex tests.
Hunter, L L; Ries, D T; Schlauch, R S; Levine, S C; Ward, W D
1999-12-01
Safety and effectiveness of acoustic reflex tests are important issues because these tests are widely applied to screen for retrocochlear pathology. Previous studies have reported moderately high sensitivity and specificity for detection of acoustic neuroma. However, there have been reports of possible iatrogenic hearing loss resulting from acoustic reflex threshold (ART) and decay (ARD) tests. This study assessed safety and clinical performance of ART tests for detection of acoustic neuroma. We report a case in which ARD testing resulted in a significant bilateral permanent threshold shift. This case was the impetus for us to investigate the clinical utility of ART and ARD tests. We analyzed sensitivity and specificity of ART, as well as asymmetry in pure-tone thresholds (PTT) for detection of acoustic neuroma in 56 tumor and 108 non-tumor ears. Sensitivity and specificity were higher for PTT asymmetry than for ART. Ipsilateral ART at 1000 Hz had poor sensitivity and specificity for detection of acoustic neuroma, and involves some potential risk to residual hearing for presentation levels higher than 115 dB SPL. Approximately half of the acoustic neuroma group had ipsilateral ARTs that would require administration of ARD tests at levels exceeding 115 dB SPL. Therefore, we conclude that PTT asymmetry is a more effective test for detection of acoustic neuroma, and involves no risk to residual hearing. Future studies of contralateral reflex threshold and ARD in combination with PTT asymmetry are recommended.
The meaning of diagnostic test results: a spreadsheet for swift data analysis.
Maceneaney, P M; Malone, D E
2000-03-01
To design a spreadsheet program to: (a) analyse rapidly diagnostic test result data produced in local research or reported in the literature; (b) correct reported predictive values for disease prevalence in any population; (c) estimate the post-test probability of disease in individual patients. Microsoft Excel(TM)was used. Section A: a contingency (2 x 2) table was incorporated into the spreadsheet. Formulae for standard calculations [sample size, disease prevalence, sensitivity and specificity with 95% confidence intervals, predictive values and likelihood ratios (LRs)] were linked to this table. The results change automatically when the data in the true or false negative and positive cells are changed. Section B: this estimates predictive values in any population, compensating for altered disease prevalence. Sections C-F: Bayes' theorem was incorporated to generate individual post-test probabilities. The spreadsheet generates 95% confidence intervals, LRs and a table and graph of conditional probabilities once the sensitivity and specificity of the test are entered. The latter shows the expected post-test probability of disease for any pre-test probability when a test of known sensitivity and specificity is positive or negative. This spreadsheet can be used on desktop and palmtop computers. The MS Excel(TM)version can be downloaded via the Internet from the URL ftp://radiography.com/pub/Rad-data99.xls A spreadsheet is useful for contingency table data analysis and assessment of the clinical meaning of diagnostic test results. Copyright 2000 The Royal College of Radiologists.
Is education associated with improvements in general cognitive ability, or in specific skills?
Ritchie, Stuart J; Bates, Timothy C; Deary, Ian J
2015-05-01
Previous research has indicated that education influences cognitive development, but it is unclear what, precisely, is being improved. Here, we tested whether education is associated with cognitive test score improvements via domain-general effects on general cognitive ability (g), or via domain-specific effects on particular cognitive skills. We conducted structural equation modeling on data from a large (n = 1,091), longitudinal sample, with a measure of intelligence at age 11 years and 10 tests covering a diverse range of cognitive abilities taken at age 70. Results indicated that the association of education with improved cognitive test scores is not mediated by g, but consists of direct effects on specific cognitive skills. These results suggest a decoupling of educational gains from increases in general intellectual capacity. (c) 2015 APA, all rights reserved).
Murungi, Moses; Fulton, Travis; Reyes, Raquel; Matte, Michael; Ntaro, Moses; Mulogo, Edgar; Nyehangane, Dan; Juliano, Jonathan J; Siedner, Mark J; Boum, Yap; Boyce, Ross M
2017-05-01
Poor specificity may negatively impact rapid diagnostic test (RDT)-based diagnostic strategies for malaria. We performed real-time PCR on a subset of subjects who had undergone diagnostic testing with a multiple-antigen (histidine-rich protein 2 and pan -lactate dehydrogenase pLDH [HRP2/pLDH]) RDT and microscopy. We determined the sensitivity and specificity of the RDT in comparison to results of PCR for the detection of Plasmodium falciparum malaria. We developed and evaluated a two-step algorithm utilizing the multiple-antigen RDT to screen patients, followed by confirmatory microscopy for those individuals with HRP2-positive (HRP2 + )/pLDH-negative (pLDH - ) results. In total, dried blood spots (DBS) were collected from 276 individuals. There were 124 (44.9%) individuals with an HRP2 + /pLDH + result, 94 (34.1%) with an HRP2 + /pLDH - result, and 58 (21%) with a negative RDT result. The sensitivity and specificity of the RDT compared to results with real-time PCR were 99.4% (95% confidence interval [CI], 95.9 to 100.0%) and 46.7% (95% CI, 37.7 to 55.9%), respectively. Of the 94 HRP2 + /pLDH - results, only 32 (34.0%) and 35 (37.2%) were positive by microscopy and PCR, respectively. The sensitivity and specificity of the two-step algorithm compared to results with real-time PCR were 95.5% (95% CI, 90.5 to 98.0%) and 91.0% (95% CI, 84.1 to 95.2), respectively. HRP2 antigen bands demonstrated poor specificity for the diagnosis of malaria compared to that of real-time PCR in a high-transmission setting. The most likely explanation for this finding is the persistence of HRP2 antigenemia following treatment of an acute infection. The two-step diagnostic algorithm utilizing microscopy as a confirmatory test for indeterminate HRP2 + /pLDH - results showed significantly improved specificity with little loss of sensitivity in a high-transmission setting. Copyright © 2017 American Society for Microbiology.
Evaluation of ID-PaGIA syphilis antibody test.
Naaber, Paul; Makoid, Ene; Aus, Anneli; Loivukene, Krista; Poder, Airi
2009-01-01
Laboratory diagnosis of syphilis is usually accomplished by serology. There are currently a large number of different commercial treponemal tests available that vary in format, sensitivity and specificity. To evaluate the ID-PaGIA Syphilis Antibody Test as an alternative to other specific treponemal tests for primary screening or confirmation of diagnosis. Serum samples from healthy adults (n = 100) were used for detection of specificity of ID-PaGIA. To evaluate sensitivity of ID-PaGIA serum samples (n = 101) from patients with confirmed or suspected syphilis were tested for syphilis antibodies with FTA-Abs IgM, ID-PaGIA, ELISA IgM and TPHA tests. No false-positive results were found with ID-PaGIA. Sensitivity of various treponemal tests was the following: FTA-Abs IgM: 95.5%, ID-PaGIA and ELISA IgM: 94%, and TPHA 75%. The positive and negative predictive values of ID-PaGIA were 100 and 89.5%, respectively. Compared with other treponemal tests ID-PaGIA has excellent sensitivity and specificity.
'Buildings in Use' Study. Technical Factors.
ERIC Educational Resources Information Center
Wisconsin Univ., Milwaukee. School of Architecture and Urban Planning.
The second report of the 'Buildings in Use' study documents the results of over 100 field tests conducted at four elementary schools, as well as discussion of these results and relevant technical specifications and details. The procedural framework used in the Field Tests Manual is followed and test results are rated numerically wherever possible.…
Comparison of the Wake-up Test and Combined TES-MEP and CSEP Monitoring in Spinal Surgery.
Chen, Bailing; Chen, Yuguang; Yang, Junlin; Xie, Denghui; Su, Haihua; Li, Fobao; Wan, Yong; Peng, Xinsheng; Zheng, Zhaomin
2015-11-01
A retrospective clinical analysis. The aim of this study was to compare the effectiveness of the wake-up test with that of combined monitoring of transcranial electrical stimulation motor evoked potentials (TES-MEP) and cortical somatosensory evoked potentials (CSEP) in spinal surgery. TES-MEP/CSEP combined monitoring is being increasingly recognized as the ideal approach to detect spinal neurophysiological compromise during spinal surgery; however, as a result the merit of the wake-up test is now in doubt. TES-MEP/CSEP combined monitoring was performed simultaneously in 426 patients who underwent spinal surgery at our department, and wake-up tests were conducted on 23 patients because of positive neurophysiological monitoring results with uncertain causes or persistent positive monitoring findings after all potential causes had been resolved. Preoperative and postoperative neurological examinations were performed as the gold standard to detect irreversible spinal function compromise. All data were collected to compare the efficiency of TES-MEP/CSEP combined monitoring with that of the wake-up test. Positive results of TES-MEP/CSEP combined monitoring were recorded in 64 cases. Among them, the positive monitoring findings agreed with the results of the neurological examination in 51 cases, and the monitoring results did not match that of neurological examination in 13 cases. No false-negative result was observed. The sensitivity of TES-MEP/CSEP monitoring was 100%, the specificity was 96.5%, and the Youden index was 0.965. Wake-up tests were conducted in 23 cases. In 8 patients the positive monitoring findings completely matched the postoperative neurological examination results. In contrast, in the other 15 cases with negative neurophysiological monitoring results, only 9 patients retained intact neurological function and 6 patients suffered compromised neurological function. The sensitivity of the wake-up test was 57.1%, the specificity was 100%, and the Youden index was 0.571. Combined TES-MEP and CSEP monitoring, with its high sensitivity and specificity, is an effective method for monitoring spinal function during surgery and should be the preferred choice. The wake-up test is a useful complementary method for monitoring because of its high specificity.
Testing the Effects of Social Anxiety Disorder on Friendship Quality Across Gender and Ethnicity
Rodebaugh, Thomas L.; Fernandez, Katya C.; Levinson, Cheri A.
2013-01-01
Previous research suggests that social anxiety disorder has a specific relationship with impairment in friendship quality; however, potential moderators of this relationship have not been tested. The current study examines whether the specific effect of social anxiety disorder on friendship quality is stable or varies across gender and ethnicity in a large epidemiological dataset. Results indicate that the underlying construct of friendship quality differed slightly but significantly between men and women; as a result, effects of social anxiety disorder were tested in men and women separately. After partially constraining friendship quality across ethnic groups, our results indicated that the relationship between social anxiety disorder and friendship quality remained robust in all groups. In addition to replicating the finding that social anxiety disorder specifically relates to perceived friendship quality, the current study highlights the need to test whether underlying constructs such as friendship quality are consistent across the groups that make up heterogeneous samples. PMID:22428540
Current methodological issues in the economic assessment of personalized medicine.
Annemans, Lieven; Redekop, Ken; Payne, Katherine
2013-01-01
There is a need for methodological scrutiny in the economic assessment of personalized medicine. In this article, we present a list of 10 specific issues that we argue pose specific methodological challenges that require careful consideration when designing and conducting robust model-based economic evaluations in the context of personalized medicine. Key issues are related to the correct framing of the research question, interpretation of test results, data collection of medical management options after obtaining test results, and expressing the value of tests. The need to formulate the research question clearly and be explicit and specific about the technology being evaluated is essential because various test kits can have the same purpose and yet differ in predictive value, costs, and relevance to practice and patient populations. The correct reporting of sensitivity/specificity, and especially the false negatives and false positives (which are population dependent), of the investigated tests is also considered as a key element. This requires additional structural complexity to establish the relationship between the test result and the consecutive treatment changes and outcomes. This process involves translating the test characteristics into clinical utility, and therefore outlining the clinical and economic consequences of true and false positives and true and false negatives. Information on treatment patterns and on their costs and outcomes, however, is often lacking, especially for false-positive and false-negative test results. The analysis can even become very complex if different tests are combined or sequentially used. This potential complexity can be handled by explicitly showing how these tests are going to be used in practice and then working with the combined sensitivities and specificities of the tests. Each of these issues leads to a higher degree of uncertainty in economic models designed to assess the added value of personalized medicine compared with their simple pharmaceutical counterparts. To some extent, these problems can be overcome by performing early population-level simulations, which can lead to the identification and collection of data on critical input parameters. Finally, it is important to understand that a test strategy does not necessarily lead to more quality-adjusted life-years (QALYs). It is possible that the test will lead to not only fewer QALYs but also fewer costs, which can be defined as "decremental" cost per QALYs. Different decision criteria are needed to interpret such results. © 2013 Published by Elsevier Inc. on behalf of International Society for Pharmacoeconomics and Outcomes Research (ISPOR).
Testing enhances both encoding and retrieval for both tested and untested items.
Cho, Kit W; Neely, James H; Crocco, Stephanie; Vitrano, Deana
2017-07-01
In forward testing effects, taking a test enhances memory for subsequently studied material. These effects have been observed for previously studied and tested items, a potentially item-specific testing effect, and newly studied untested items, a purely generalized testing effect. We directly compared item-specific and generalized forward testing effects using procedures to separate testing benefits due to encoding versus retrieval. Participants studied two lists of Swahili-English word pairs, with the second study list containing "new" pairs intermixed with the previously studied "old" pairs. Participants completed a review phase in which they took a cued-recall test on only the "old" pairs or restudied them. In Experiments 1a, 1b, and 2, the review phase was given either before or after the second study list. Testing benefited memory to the same degree for both "new" and "old" pairs, suggesting that there were no pair-specific benefits of testing. The larger benefit from testing when review was given before rather than after the second study list suggests that the memory enhancement was due to both testing-enhanced encoding and testing-enhanced retrieval. To better equate generalized testing effects for "new" and "old" pairs, Experiment 3 intermixed them in the review phase. A statistically significant pair-specific testing effect for "old" items was now observed. Overall, these results show that forward testing effects are due to both testing-enhanced encoding and retrieval effects and that direct, pair-specific forward testing benefits are considerably smaller than indirect, generalized forward testing benefits.
Does McNemar's test compare the sensitivities and specificities of two diagnostic tests?
Kim, Soeun; Lee, Woojoo
2017-02-01
McNemar's test is often used in practice to compare the sensitivities and specificities for the evaluation of two diagnostic tests. For correct evaluation of accuracy, an intuitive recommendation is to test the diseased and the non-diseased groups separately so that the sensitivities can be compared among the diseased, and specificities can be compared among the healthy group of people. This paper provides a rigorous theoretical framework for this argument and study the validity of McNemar's test regardless of the conditional independence assumption. We derive McNemar's test statistic under the null hypothesis considering both assumptions of conditional independence and conditional dependence. We then perform power analyses to show how the result is affected by the amount of the conditional dependence under alternative hypothesis.
Venco, Luigi; Manzocchi, Simone; Genchi, Marco; Kramer, Laura H
2017-11-09
Heartworm antigen testing is considered sensitive and specific. Currently available tests are reported as detecting a glycoprotein found predominantly in the reproductive tract of the female worm and can reach specificity close to 100%. Main concerns regard sensitivity in the case of light infections, the presence of immature females or cases of all-male infections. Research and development have been aimed at increasing sensitivity. Recently, heat treatment of serum prior to antigen testing has been shown to result in an increase in positive antigen test results, presumably due to disruption of natural antigen-antibody complexes. Cross-reactions in dogs with both natural and experimental infections with Angiostrongylus vasorum and Spirocerca lupi have been reported, but cross-reactions with other helminths have not been extensively studied. In order to evaluate potential cross-reactivity with other canine and feline parasites, two studies were performed. Study 1: Live adults of Dirofilaria immitis, Dirofilaria repens, Toxocara canis, Toxocara cati, Dipylidium caninum, Taenia taeniaeformis and Mesocestoides spp. larvae were washed and incubated in tubes with saline solution. All worms were alive at the time of removal from the saline. Saline solutions containing excretory/secretory antigens were then tested for heartworm with six different, commercially available antigen tests. All results were evaluated blind by three of the authors. Study 2: Sera from dogs with natural infections by A. vasorum or D. repens, living in areas free of heartworm disease, were tested with the same tests before and after heat treatment (103 °C for 10 min). Results suggest that antigens detected by currently available tests are not specific for D. immitis. They may give positive results through detection of different parasites' antigens that are normally not released into the bloodstream or released in a low amount and/or bound to antibodies. Tests may even detect antigens released by male D. immitis adult worms. D. repens appears to release more detectable antigens than the other worms studied. Cross-reaction with A. vasorum and D. repens does occur in the field and could potentially occur with other helminths. Heat treatment decreases specificity by enhancing cross-reactivity.
Singh, N; Saxena, A; Sharma, V P
2002-10-01
The performance of a new indigenous rapid diagnostic test, Paracheck Pf was evaluated in detection of Plasmodium falciparum in asymptomatic children in remote forest villages of Mandla district, central India to determine the lower limits of sensitivity and specificity of rapid test. A finger prick blood sample was collected to prepare blood smear and for testing with the Paracheck test. The blood smears were read by an experienced technician blinded to the Paracheck results. The figures for specificity, sensitivity, accuracy and predictive values were calculated using microscopy as gold standard. The new diagnostic test had a sensitivity of 94% and a specificity of 89%. The positive and negative predictive values were 71% and 98%, respectively. The J -index was 0.83%. The rapid test was found to be very easy to perform and the result could be read reliably by field workers. The field evaluation with this new inexpensive test, ($0.65/test) indicates that it could be used as an epidemiological tool in the management of malaria particularly in areas where microscopy is not operationally feasible to attain the goal of the roll back malaria initiative.
Giraldo, Mónica; Portela, Ricardo W. D.; Snege, Mirian; Leser, Paulo G.; Camargo, Mário E.; Mineo, José Roberto; Gazzinelli, Ricardo T.
2002-01-01
In the present study we developed an enzyme-linked immunosorbent assay (ELISA) to measure immunoglobulin M (IgM) specific for glycoinositolphospholipids (GIPL) derived from tachyzoite membrane (IgM-GIPL ELISA). The sensitivity and specificity of the assay were compared with those of commercially available Toxoplasma-specific IgM serological tests, namely, immunofluorescence assay (IFA) with fixed tachyzoites and capture ELISA employing tachyzoite extracts. Our results show that all patients with acute toxoplasmosis, as determined by clinical data and conventional serological tests, were also positive by the IgM-GIPL ELISA. Interestingly, many patients that were classified as indeterminate, who had IgG with high avidity but positive results in the IgM-specific IFA and capture ELISA, were negative by the IgM-GIPL ELISA. Finally, we tested the sera from patients with rheumatoid arthritis and various parasitic infections and found no evidence of false positives in the IgM-GIPL ELISA. PMID:11923364
Ates, Gamze; Doktorova, Tatyana Y; Pauwels, Marleen; Rogiers, Vera
2014-03-01
To evaluate the mutagenicity/genotoxicity of cosmetic ingredients at the regulatory level, usually a battery of three in vitro tests is applied. This battery, designed to be very sensitive, produces a high number of positive results, imposing the need for in vivo follow-up testing to clear the substance under study. In Europe, the use of experimental animals has become impossible for cosmetic ingredients due to the implementation of animal testing and marketing bans. Consequently, the possibility to 'de-risk' substances with positive in vitro results disappear and potentially safe cosmetic substances will be lost for the EU market unless currently used in vitro assays can be adapted or new non-animal mutagenicity/genotoxicity studies become available. Described strategies to improve the specificity of existing in vitro assays include optimisation of the used cell type and cytotoxicity assay and lowering of the applied top concentration. A reduction of the number of tests in the battery from three to two also has been suggested. In this study, the performance of the 'standard' in vitro mutagenicity/genotoxicity testing battery is analysed for a number of cosmetic ingredients. We composed a database with toxicological information on 249 cosmetic ingredients, mainly present on the Annexes of the European cosmetic legislation. Results revealed that the in vitro mutagenicity/genotoxicity tests showed a low specificity for the cosmetic ingredients concerned, comparable to the specificity published for chemicals. Non-confirmed or 'misleading' positive results amounted up to 93% for the in vitro test batteries. The cell type and top concentrations did not have a major impact on the specificity. With respect to cytotoxicity determinations, different end points were used, potentially leading to different testing concentrations, suggesting the need for a consensus in this matter. Overall, the results of this retrospective analysis point to an urgent need of better regulatory strategies to assess the potential mutagenicity/genotoxicity of cosmetic ingredients.
Standard Procedures for Air Force Operational Test and Evaluation. Volume I. Appendices
1974-10-01
Participates in selected tests data for assessment of suitability Participates in the intepretation of and effectiveness, as practicable tet results...selected tests Interprels test results Inteprets test resultst ReplRorts to CNO the results of the "eports independent operational TI’ECIIEVAL assessment" v... films , lists, tapes, drawings, specifications. parts breakdowns, ctc. RAW DATA; ’The original form of data at the time it was recorded. DATA
NASA Astrophysics Data System (ADS)
Priebe, Elizabeth H.; Neville, C. J.; Rudolph, D. L.
2018-03-01
The spatial coverage of hydraulic conductivity ( K) values for large-scale groundwater investigations is often poor because of the high costs associated with hydraulic testing and the large areas under investigation. Domestic water wells are ubiquitous and their well logs represent an untapped resource of information that includes mandatory specific-capacity tests, from which K can be estimated. These specific-capacity tests are routinely conducted at such low pumping rates that well losses are normally insignificant. In this study, a simple and practical approach to augmenting high-quality K values with reconnaissance-level K values from water-well specific-capacity tests is assessed. The integration of lesser quality K values from specific-capacity tests with a high-quality K data set is assessed through comparisons at two different scales: study-area-wide (a 600-km2 area in Ontario, Canada) and in a single geological formation within a portion of the broader study area (200 km2). Results of the comparisons demonstrate that reconnaissance-level K estimates from specific-capacity tests approximate the ranges and distributions of the high-quality K values. Sufficient detail about the physical basis and assumptions that are invoked in the development of the approach are presented here so that it can be applied with confidence by practitioners seeking to enhance their spatial coverage of K values with specific-capacity tests.
Establishing a sample-to cut-off ratio for lab-diagnosis of hepatitis C virus in Indian context.
Tiwari, Aseem K; Pandey, Prashant K; Negi, Avinash; Bagga, Ruchika; Shanker, Ajay; Baveja, Usha; Vimarsh, Raina; Bhargava, Richa; Dara, Ravi C; Rawat, Ganesh
2015-01-01
Lab-diagnosis of hepatitis C virus (HCV) is based on detecting specific antibodies by enzyme immuno-assay (EIA) or chemiluminescence immuno-assay (CIA). Center for Disease Control reported that signal-to-cut-off (s/co) ratios in anti-HCV antibody tests like EIA/CIA can be used to predict the probable result of supplemental test; above a certain s/co value it is most likely to be true-HCV positive result and below that certain s/co it is most likely to be false-positive result. A prospective study was undertaken in patients in tertiary care setting for establishing this "certain" s/co value. The study was carried out in consecutive patients requiring HCV testing for screening/diagnosis and medical management. These samples were tested for anti-HCV on CIA (VITROS(®) Anti-HCV assay, Ortho-Clinical Diagnostics, New Jersey) for calculating s/co value. The supplemental nucleic acid test used was polymerase chain reaction (PCR) (Abbott). PCR test results were used to define true negatives, false negatives, true positives, and false positives. Performance of different putative s/co ratios versus PCR was measured using sensitivity, specificity, positive predictive value and negative predictive value and most appropriate s/co was considered on basis of highest specificity at sensitivity of at least 95%. An s/co ratio of ≥6 worked out to be over 95% sensitive and almost 92% specific in 438 consecutive patient samples tested. The s/co ratio of six can be used for lab-diagnosis of HCV infection; those with s/co higher than six can be diagnosed to have HCV infection without any need for supplemental assays.
Stavri, Henriette; Bucurenci, Nadia; Ulea, Irina; Costache, Adriana; Popa, Loredana; Popa, Mircea Ioan
2012-11-01
Purified protein derivative (PPD) is currently the only available skin test reagent used worldwide for the diagnosis of tuberculosis (TB). The aim of this study was to develop a Mycobacterium tuberculosis specific skin test reagent, without false positive results due to Bacillus Calmette-Guerin (BCG) vaccination using recombinant antigens. Proteins in PPD IC-65 were analyzed by tandem mass spectrometry and compared to proteins in M. tuberculosis culture filtrate; 54 proteins were found in common. Top candidates MPT64, ESAT 6, and CFP 10 were overexpressed in Escherichia coli expression strains and purified as recombinant proteins. To formulate optimal immunodiagnostic PPD cocktails, the antigens were evaluated by skin testing guinea pigs sensitized with M. tuberculosis H37Rv and BCG. For single antigens and a cocktail mixture of these antigens, best results were obtained using 3 μg/0.1 ml, equivalent to 105 TU (tuberculin units). Each animal was simultaneously tested with PPD IC-65, 2 TU/0.1 ml, as reference. Reactivity of the multi-antigen cocktail was greater than that of any single antigen. The skin test results were between 34.3 and 76.6 per cent the level of reactivity compared to that of the reference when single antigens were tested and 124 per cent the level of reactivity compared to the reference for the multi-antigen cocktail. Our results showed that this specific cocktail could represent a potential candidate for a new skin diagnostic test for TB.
de Vos, Gabriele; Nazari, Ramin; Ferastraoaru, Denisa; Parikh, Purvi; Geliebter, Rebecca; Pichardo, Yikania; Wiznia, Andrew; Rosenstreich, David
2013-06-01
Atopic sensitization to aeroallergens in early life has been found to be a strong risk factor for the development of persisting asthma in young children with recurrent wheeze. To assess the yield of skin prick test (SPT) compared with allergen specific serum IgE (sIgE) testing at identifying aeroallergen sensitization in atopic children younger than 4 years. Concordance between SPT and allergen-specific sIgE testing for 7 common aeroallergens was analyzed in 40 atopic inner-city children 18 to 48 months of age (mean [SD], 36 [9] months) with recurrent wheezing and family history of asthma and/or eczema. In 80% of children one or more allergen sensitizations would have been missed if only SPT had been performed, and in 38% of children one or more sensitizations would have been missed if only sIgE testing had been performed. Agreement between the SPT and sIgE test was fair for most allergens (κ = -0.04 to 0.50), as was correlation between sIgE levels and SPT grade (ρ = 0.21 to 0.55). Children with high total sIgE (≥300 kU/L) were more likely to have positive sIgE test results, with negative corresponding SPT results (P = .02). Our study revealed a significant discordance between allergen-specific SPT and sIgE testing results for common aeroallergens, suggesting that both SPT and sIgE testing should be performed when diagnosing allergic sensitization in young children at high risk of asthma. clinicaltrials.gov Identifier: NCT01028560. Copyright © 2013 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
van't Hoog, Anna H; Cobelens, Frank; Vassall, Anna; van Kampen, Sanne; Dorman, Susan E; Alland, David; Ellner, Jerrold
2013-01-01
High costs are a limitation to scaling up the Xpert MTB/RIF assay (Xpert) for the diagnosis of tuberculosis in resource-constrained settings. A triaging strategy in which a sensitive but not necessarily highly specific rapid test is used to select patients for Xpert may result in a more affordable diagnostic algorithm. To inform the selection and development of particular diagnostics as a triage test we explored combinations of sensitivity, specificity and cost at which a hypothetical triage test will improve affordability of the Xpert assay. In a decision analytical model parameterized for Uganda, India and South Africa, we compared a diagnostic algorithm in which a cohort of patients with presumptive TB received Xpert to a triage algorithm whereby only those with a positive triage test were tested by Xpert. A triage test with sensitivity equal to Xpert, 75% specificity, and costs of US$5 per patient tested reduced total diagnostic costs by 42% in the Uganda setting, and by 34% and 39% respectively in the India and South Africa settings. When exploring triage algorithms with lower sensitivity, the use of an example triage test with 95% sensitivity relative to Xpert, 75% specificity and test costs $5 resulted in similar cost reduction, and was cost-effective by the WHO willingness-to-pay threshold compared to Xpert for all in Uganda, but not in India and South Africa. The gain in affordability of the examined triage algorithms increased with decreasing prevalence of tuberculosis among the cohort. A triage test strategy could potentially improve the affordability of Xpert for TB diagnosis, particularly in low-income countries and with enhanced case-finding. Tests and markers with lower accuracy than desired of a diagnostic test may fall within the ranges of sensitivity, specificity and cost required for triage tests and be developed as such.
The Oral Provocation Test for Raw Egg in Patients with Hen Egg Allergy.
Kido, Jun; Nishi, Natsuko; Matsumoto, Tomoaki
2018-06-06
Many researchers have made efforts to develop diagnostic tools for predicting the outcome of oral food challenges (OFCs). The aim of this study was to assess the diagnostic value of the skin prick test (SPT) and blood-specific IgE concentrations based on the outcome of the OFCs for heated and raw hen egg. This study included 103 children with suspected hen egg allergy (HEA; median age 23 months, range 10-155; 72 boys, 31 girls). Forty-three patients were diagnosed with HEA by OFC. Of 60 patients who tolerated heated egg white (HEW), 22 underwent the OFC for raw hen egg and 7 developed adverse reactions after ingesting raw egg. Their wheal diameters and specific IgE levels for egg white and ovomucoid were determined. Wheal diameters as well as blood-specific IgE levels for egg white and ovomucoid were significantly larger in children with positive OFC results for HEW than in those with negative results. However, there were no significant differences between the positive and negative test results for raw hen egg white (REW) in wheal diameter or blood-specific IgE levels. The SPT and blood-specific IgE can be used to diagnose HEA. However, the provocation test for REW in children without HEW allergy is important because the values of SPT and specific IgE were not significantly different between children with and without raw egg allergy. © 2018 S. Karger AG, Basel.
Mattioli, Flavia; Bellomi, Fabio; Stampatori, Chiara; Provinciali, Leandro; Compagnucci, Laura; Uccelli, Antonio; Pardini, Matteo; Santuccio, Giuseppe; Fregonese, Giuditta; Pattini, Marianna; Allegri, Beatrice; Clerici, Raffaella; Lattuada, Annalisa; Montomoli, Cristina; Corso, Barbara; Gallo, Paolo; Riccardi, Alice; Ghezzi, Angelo; Roscio, Marco; Tola, Maria Rosaria; Calanca, Chiara; Baldini, Daria; Trafficante, Debora; Capra, Ruggero
2016-01-01
Cognitive rehabilitation in multiple sclerosis (MS) has been reported to induce neuropsychological improvements, but the persistence of these effects has been scarcely investigated over long follow ups. Here, the results of a multicenter randomized clinical trial are reported, in which the efficacy of 15 week domain specific cognitive training was evaluated at 2 years follow up in 41 patients. Included patients were randomly assigned either to domain specific cognitive rehabilitation, or to aspecific psychological intervention. Patients who still resulted to be cognitively impaired at 1 year follow up were resubmitted to the same treatment, whereas the recovered ones were not. Neuropsychological tests and functional scales were administered at 2 years follow up to all the patients. Results revealed that both at 1 and at 2 years follow up more patients in the aspecific group (18/19, 94% and 13/17, 76% respectively) than in the specific group (11/22, 50% and 5/15, 33% respectively) resulted to be cognitively impaired. Furthermore patients belonging to the specific group showed significantly less impaired tests compared with the aspecific group ones (p = 0.02) and a significant amelioration in the majority of the tests. On the contrary patients in the aspecific group did not change. The specific group subjects also perceived a subjective improvement in their cognitive performance, while the aspecific group patients did not. These results showed that short time domain specific cognitive rehabilitation is a useful treatment for patients with MS, shows very long lasting effects, compared to aspecific psychological interventions. Also subjective cognitive amelioration was found in patients submitted to domain specific treatment after 2 years. PMID:26941630
Buddle, Bryce M; Wilson, Tania; Denis, Michel; Greenwald, Rena; Esfandiari, Javan; Lyashchenko, Konstantin P; Liggett, Simon; Mackintosh, Colin G
2010-04-01
In this study, novel serological tests were used to detect tuberculosis (TB) in groups of farmed red deer (Cervus elaphus) varying in disease status or possible confounding factors. Groups of deer naturally or experimentally infected with Mycobacterium bovis and animals vaccinated against paratuberculosis were studied, as were uninfected animals and animals naturally or experimentally infected with Mycobacterium avium subsp. paratuberculosis. Sera were assayed using two rapid lateral-flow tests, Chembio's CervidTB STAT-PAK and DPP VetTB tests, and results were compared to those from tuberculin skin tests. Both serological tests had a high sensitivity, but specificity was adversely affected after animals had received a vaccine against paratuberculosis and were subsequently skin tested. The specificity of the DPP VetTB test was higher than that of the CervidTB STAT-PAK test, with natural infection with M. avium subsp. paratuberculosis adversely affecting the specificity of only the CervidTB STAT-PAK test. The sera from M. avium subsp. paratuberculosis-infected deer that produced false-positive reactions in the CervidTB STAT-PAK test were retested with a multiantigen print immunoassay (MAPIA), and some of these sera were shown to react with the MPB83 antigen. Combining the results from the serological tests and the skin tests showed only a slight increase in the sensitivity of detection of M. bovis-infected animals. It is concluded that both the CervidTB STAT-PAK and DPP VetTB tests offer rapid, convenient, and easy detection of bovine tuberculosis in deer, albeit with significant interference from paratuberculosis vaccination status and subsequent skin testing. The latter finding illustrates one of the limitations of currently available vaccines against paratuberculosis.
Zenilman, J M; Miller, W C; Gaydos, C; Rogers, S M; Turner, C F
2003-04-01
Nucleic acid amplification tests have facilitated field based STD studies and increased screening activities. However, even with highly specific tests, the positive predictive value (PPV) of such tests may be lower than desirable in low prevalence populations. We estimated PPVs for a single LCR test in a population survey in which positive specimens were retested. The Baltimore STD and Behavior Survey (BSBS) was a population based behavioural survey of adults which included collecting urine specimens to assess the prevalence of gonorrhoea and chlamydial infection. Gonorrhoea and chlamydial infection were diagnosed by ligase chain reaction (LCR). Nearly all positive results were retested by LCR. Because of cost considerations, negative results were not confirmed. Predicted curves for the PPV were calculated for a single testing assuming an LCR test sensitivity of 95%, and test specificities in the range 95.0%-99.9%, for disease prevalences between 1% and 10%. Positive specimens were retested to derive empirical estimates of the PPV of a positive result on a single LCR test. 579 participants age 18-35 provided urine specimens. 20 (3.5%) subjects initially tested positive for chlamydial infection, and 39 (6.7%) tested positive for gonococcal infection. If positive results on the repeat LCR are taken as confirmation of a "true" infection, the observed PPV for the first LCR testing was 89.5% for chlamydial infection and 83.3% for gonorrhoea. This is within the range of theoretical PPVs calculated from the assumed sensitivities and specificities of the LCR assays. Empirical performance of a single LCR testing approximated the theoretically predicted PPV in this field study. This result demonstrates the need to take account of the lower PPVs obtained when such tests are used in field studies or clinical screening of low prevalence populations. Repeat testing of specimens, preferably with a different assay (for example, polymerase chain reaction), and disclosure of the non-trivial potential for false positive test results would seem appropriate in all such studies.
Mattioli, Flavia; Stampatori, Chiara; Bellomi, Fabio; Danni, Maura; Compagnucci, Laura; Uccelli, Antonio; Pardini, Matteo; Santuccio, Giuseppe; Fregonese, Giuditta; Pattini, Marianna; Allegri, Beatrice; Clerici, Raffaella; Lattuada, Annalisa; Montomoli, Cristina; Corso, Barbara; Capra, Ruggero
2015-01-01
Background: Specific cognitive rehabilitation in multiple sclerosis (MS) resulted to be effective compared to no treatment. So far the possible role of an aspecific psychological intervention on cognition has not been investigated. Objective: The aim of the SMICT RCT was to compare the efficacy of a specific cognitive training with an aspecific psychological intervention in relapsing-remitting MS patients. Methods: From a sample of 150 patients, with the same disability and immunomodulatory therapy, submitted to neuropsychological examination, 45 impaired in at least one test were included and 41 randomized to have either a specific cognitive training for the impaired function (22) or to an aspecific psychological intervention (19) for 4 months, starting after baseline examination. Neuropsychological tests and functional scales were administered at baseline and 1 year later. Results: After 1 year, the mean number of pathological tests was significantly lower in the specific treatment group, compared to the aspecific group. Memory and attention/speeded information processing functions were mostly improved. Depression and quality of life were not different between groups at follow up. Conclusion: Our study demonstrates that an intensive and domain specific cognitive approach results to be more effective than aspecific psychological intervention in patients with MS. PMID:25628596
40 CFR Appendix B to Part 60 - Performance Specifications
Code of Federal Regulations, 2010 CFR
2010-07-01
... series of design and performance specifications and test procedures to certify opacity monitoring... Performance Specification 1? Performance Specification 1 (PS-1) provides (1) requirements for the design... apply to COMS data? The measurement uncertainties associated with COMS data result from several design...
... Some labs use different measurements or test different samples. Talk to your doctor about the meaning of your specific test results. What Abnormal Results Mean Levels below 60 mL/min/1.73 m 2 for 3 or more months ...
Relationship between general and specific coordination in 8- to 17-year-old male basketball players.
Kamandulis, Sigitas; Venckūnas, Tomas; Masiulis, Nerijus; Matulaitis, Kestutis; Balciūnas, Mindaugas; Peters, Derek; Skurvydas, Albertas
2013-12-01
The purpose of the present study was to investigate the relationships between general coordination, sport-specific coordination, and sport-specific fitness of 8- to 17-year-old male basketball players. 312 males with training experience ranging from one year in the 8-year-old cohort up to 10 years for the 17-year-olds performed basketball-specific fitness (20 m sprint, Illinois, countermovement jump), general coordination (20 m run with three obstacles), semi-basketball-specific coordination (20 m sprint dribbling two balls, countermovement jump with arm swing) and basketball-specific coordination (Illinois ball dribbling) tests. There were moderate to large correlations between the results of both general and basketball-specific coordination with the results of most basketball-specific coordination tests in all age groups. Correlations between general and basketball-specific coordination were large in four age groups (11-14 yr., r = .52 to r = .76), moderate in five groups (8-10, 15 & 16 yr., r = .37 to r = .46), while not significant in the 17-year-olds. These results suggest that the importance of general coordination for sport-specific skills improvements during a sports-specific skill acquisition phase, remains high at the skill refinement phase, and decreases when sport-specific skills have been mastered to near-perfection.
A comparison of five serological tests for bovine brucellosis.
Dohoo, I R; Wright, P F; Ruckerbauer, G M; Samagh, B S; Robertson, F J; Forbes, L B
1986-01-01
Five serological assays: the buffered plate antigen test, the standard tube agglutination test, the complement fixation test, the hemolysis-in-gel test and the indirect enzyme immunoassay were diagnostically evaluated. Test data consisted of results from 1208 cattle in brucellosis-free herds, 1578 cattle in reactor herds of unknown infection status and 174 cattle from which Brucella abortus had been cultured. The complement fixation test had the highest specificity in both nonvaccinated and vaccinated cattle. The indirect enzyme immunoassay, if interpreted at a high threshold, also exhibited a high specificity in both groups of cattle. The hemolysis-in-gel test had a very high specificity when used in nonvaccinated cattle but quite a low specificity among vaccinates. With the exception of the complement fixation test, all tests had high sensitivities if interpreted at the minimum threshold. However, the sensitivities of the standard tube agglutination test and indirect enzyme immunoassay, when interpreted at high thresholds were comparable to that of the complement fixation test. A kappa statistic was used to measure the agreement between the various tests. In general the kappa statistics were quite low, suggesting that the various tests may detect different antibody isotypes. There was however, good agreement between the buffered plate antigen test and standard tube agglutination test (the two agglutination tests evaluated) and between the complement fixation test and the indirect enzyme immunoassay when interpreted at a high threshold. With the exception of the buffered plate antigen test, all tests were evaluated as confirmatory tests by estimating their specificity and sensitivity on screening-test positive samples.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:3539295
Sharma, Hemant P; Wood, Robert A; Bravo, Andrea R; Matsui, Elizabeth C
2008-04-01
Mouse sensitization is assessed by using skin testing and serum levels of mouse allergen-specific IgE (m-IgE). However, it is unknown whether a positive skin test response or m-IgE result accurately identifies those with clinically relevant mouse sensitization. We sought to compare skin testing and m-IgE measurement in the diagnosis of mouse allergy. Sixty-nine mouse laboratory workers underwent skin prick tests (SPTs), intradermal tests (IDTs), and serum IgE measurements to mouse allergen, followed by nasal challenge to increasing concentrations of mouse allergen. Challenge response was assessed by nasal symptom score. Thirty-eight women and 31 men with a mean age of 30 years were studied. Forty-nine workers reported mouse-related symptoms, of whom 10 had positive m-IgE results and 12 had positive SPT responses. Fifteen had negative SPT responses but positive IDT responses. Positive nasal challenges were observed in 70% of workers with positive m-IgE results, 83% of workers with positive SPT responses, 33% of workers with negative SPT responses/positive IDT responses, and 0% of workers with negative IDT responses. SPTs performed best, having the highest positive and negative predictive values. Among participants with a positive challenge result, those with a positive SPT response or m-IgE result had a significantly lower challenge threshold than those with a positive IDT response (P = .01). Workers with a positive challenge result were more likely to have an increase in nasal eosinophilia after the challenge compared with those with a negative challenge result (P = .03). SPTs perform best in discriminating patients with and without mouse allergy. Mouse-specific IgE and IDTs appear to be less useful than SPTs in the diagnosis of mouse allergy.
The Diagnostic Accuracy of Special Tests for Rotator Cuff Tear: The ROW Cohort Study
Jain, Nitin B.; Luz, Jennifer; Higgins, Laurence D.; Dong, Yan; Warner, Jon J.P.; Matzkin, Elizabeth; Katz, Jeffrey N.
2016-01-01
Objective The aim was to assess diagnostic accuracy of 15 shoulder special tests for rotator cuff tears. Design From 02/2011 to 12/2012, 208 participants with shoulder pain were recruited in a cohort study. Results Among tests for supraspinatus tears, Jobe’s test had a sensitivity of 88% (95% CI=80% to 96%), specificity of 62% (95% CI=53% to 71%), and likelihood ratio of 2.30 (95% CI=1.79 to 2.95). The full can test had a sensitivity of 70% (95% CI=59% to 82%) and a specificity of 81% (95% CI=74% to 88%). Among tests for infraspinatus tears, external rotation lag signs at 0° had a specificity of 98% (95% CI=96% to 100%) and a likelihood ratio of 6.06 (95% CI=1.30 to 28.33), and the Hornblower’s sign had a specificity of 96% (95% CI=93% to 100%) and likelihood ratio of 4.81 (95% CI=1.60 to 14.49). Conclusions Jobe’s test and full can test had high sensitivity and specificity for supraspinatus tears and Hornblower’s sign performed well for infraspinatus tears. In general, special tests described for subscapularis tears have high specificity but low sensitivity. These data can be used in clinical practice to diagnose rotator cuff tears and may reduce the reliance on expensive imaging. PMID:27386812
Godden, S M; Royster, E; Timmerman, J; Rapnicki, P; Green, H
2017-08-01
Study objectives were to (1) describe the diagnostic test characteristics of an automated milk leukocyte differential (MLD) test and the California Mastitis Test (CMT) to identify intramammary infection (IMI) in early- (EL) and late-lactation (LL) quarters and cows when using 3 different approaches to define IMI from milk culture, and (2) describe the repeatability of MLD test results at both the quarter and cow level. Eighty-six EL and 90 LL Holstein cows were sampled from 3 Midwest herds. Quarter milk samples were collected for a cow-side CMT test, milk culture, and MLD testing. Quarter IMI status was defined by 3 methods: culture of a single milk sample, culture of duplicate samples with parallel interpretation, and culture of duplicate samples with serial interpretation. The MLD testing was completed in duplicate within 8 h of sample collection; MLD results (positive/negative) were reported at each possible threshold setting (1-18 for EL; 1-12 for LL) and CMT results (positive/negative) were reported at each possible cut-points (trace, ≥1, ≥2, or 3). We created 2 × 2 tables to compare MLD and CMT results to milk culture, at both the quarter and cow level, when using each of 3 different definitions of IMI as the referent test. Paired MLD test results were compared with evaluate repeatability. The MLD test showed excellent repeatability. The choice of definition of IMI from milk culture had minor effects on estimates of MLD and CMT test characteristics. For EL samples, when interpreting MLD and CMT results at the quarter level, and regardless of the referent test used, both tests had low sensitivity (MLD = 11.7-39.1%; CMT = 0-52.2%) but good to very good specificity (MLD = 82.1-95.2%; CMT = 68.1-100%), depending on the cut-point used. Sensitivity improved slightly if diagnosis was interpreted at the cow level (MLD = 25.6-56.4%; CMT = 0-72.2%), though specificity generally declined (MLD = 61.8-100%; CMT = 25.0-100%) depending on the cut-point used. For LL samples, when interpreted at the quarter level, both tests had variable sensitivity (MLD = 46.6-84.8%; CMT = 9.6-72.7%) and variable specificity (MLD = 59.2-79.8%; CMT = 52.5-97.3%), depending on the cut-point used. Test sensitivity improved if interpreted at the cow level (MLD = 59.6-86.4%; CMT = 19.1-86.4%), though specificity declined (MLD = 32.4-56.8%; CMT = 14.3-92.3%). Producers considering adopting either test for LL or EL screening programs will need to carefully consider the goals and priorities of the program (e.g., whether to prioritize test sensitivity or specificity) when deciding on the level of interpretation (quarter or cow) and when selecting the optimal cut-point for interpreting test results. Additional validation studies and large randomized field studies will be needed to evaluate the effect of adopting either test in selective dry cow therapy or fresh cow screening programs on udder health, antibiotic use, and economics. The Authors. Published by the Federation of Animal Science Societies and Elsevier Inc. on behalf of the American Dairy Science Association®. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
Sulaiman, Ar; Yusof, Zakaria; Munajat, I; Lee, Naa; Zaki, Nik
2011-11-01
We conducted this study to compare the specificity and sensitivity of the Ortolani and Barlow tests performed by dedicated examiners, and to ascertain the incidence of developmental dysplasia of the hip (DDH) in breech babies. A dedicated examiner underwent specific training and testing by a paediatric orthopaedic surgeon. Routine examiners were medical officers who had basic training in medical school and were briefly trained by their superiors. The dedicated examiner examined 170 babies. Thirty babies including 5 babies with positive tests (according to the dedicated examiner) were examined by a blinded routine examiner. RESULTS of Ortolani and Barlow tests on 30 babies were compared with ultrasound examination by blinded radiologist. Five babies had positive Ortolani and Barlow tests. The routine examiner did not detect positive Ortolani and Barlow tests. The incidence of positive Ortolani and Barlow tests among breech babies was 2.8%. Result of Ortolani and Barlow tests by dedicated hip screener were better than results performed by routine examiner. Ortolani and Barlow, Dedicated Examiner, Routine Examiner, Breech, Ultrasound.
Positive Skin Test or Specific IgE to Penicillin Does Not Reliably Predict Penicillin Allergy.
Tannert, Line Kring; Mortz, Charlotte Gotthard; Skov, Per Stahl; Bindslev-Jensen, Carsten
According to guidelines, patients are diagnosed with penicillin allergy if skin test (ST) result or specific IgE (s-IgE) to penicillin is positive. However, the true sensitivity and specificity of these tests are presently not known. To investigate the clinical relevance of a positive ST result and positive s-IgE and to study the reproducibility of ST and s-IgE. A sample of convenience of 25 patients with positive penicillin ST results, antipenicillin s-IgE results, or both was challenged with their culprit penicillin. Further 19 patients were not challenged, but deemed allergic on the basis of a recent anaphylactic reaction or delayed reactions to skin testing. Another sample of convenience of 18 patients, 17 overlapping with the 25 challenged, with initial skin testing and s-IgE (median, 25; range, 3-121), months earlier (T -1 ), was repeat skin tested and had s-IgE measured (T 0 ), and then skin tested and had s-IgE measured 4 weeks later (T 1 ). Only 9 (36%) of 25 were challenge positive. There was an increased probability of being penicillin allergic if both ST result and s-IgE were positive at T 0 . Positive ST result or positive s-IgE alone did not predict penicillin allergy. Among the 18 patients repeatedly tested, 46.2% (12 of 25) of positive ST results at T -1 were reproducibly positive at T 0 . For s-IgE, 54.2% (14 of 24) positive measurements were still positive at T 0 and 7 converted to positive at T 1 . The best predictor for a clinically significant (IgE-mediated) penicillin allergy is a combination of a positive case history with simultaneous positive ST result and s-IgE or a positive challenge result. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Kunkle, Gerald A.
2016-05-04
The procedures followed and the results obtained from the testing are described in this publication. The device met most of the manufacturer’s stated specifications. An exception was power consumption, which was about 10 percent above the manufacturer’s specifications. It was also observed that enabling WiFi doubles the Storm 3’s power consumption. In addition, several logging errors were made by two units during deployment testing, but it could not be determined whether these errors were the fault of the Storm or of an attached sensor.
Horita, Nobuyuki; Miyazawa, Naoki; Kojima, Ryota; Kimura, Naoko; Inoue, Miyo; Ishigatsubo, Yoshiaki; Kaneko, Takeshi
2013-11-01
Studies on the sensitivity and specificity of the Binax Now Streptococcus pneumonia urinary antigen test (index test) show considerable variance of results. Those written in English provided sufficient original data to evaluate the sensitivity and specificity of the index test using unconcentrated urine to identify S. pneumoniae infection in adults with pneumonia. Reference tests were conducted with at least one culture and/or smear. We estimated sensitivity and two specificities. One was the specificity evaluated using only patients with pneumonia of identified other aetiologies ('specificity (other)'). The other was the specificity evaluated based on both patients with pneumonia of unknown aetiology and those with pneumonia of other aetiologies ('specificity (unknown and other)') using a fixed model for meta-analysis. We found 10 articles involving 2315 patients. The analysis of 10 studies involving 399 patients yielded a pooled sensitivity of 0.75 (95% confidence interval: 0.71-0.79) without heterogeneity or publication bias. The analysis of six studies involving 258 patients yielded a pooled specificity (other) of 0.95 (95% confidence interval: 0.92-0.98) without no heterogeneity or publication bias. We attempted to conduct a meta-analysis with the 10 studies involving 1916 patients to estimate specificity (unknown and other), but it remained unclear due to moderate heterogeneity and possible publication bias. In our meta-analysis, sensitivity of the index test was moderate and specificity (other) was high; however, the specificity (unknown and other) remained unclear. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.
NASA Astrophysics Data System (ADS)
Kasai, R.; Abe, T.; Sano, T.
Automated electromagnetic compatibility (EMC) tests for spacecraft hardware are described. EMC tests are divided into three categories: compensating measurement and calibration errors, comparison of test results with specification, and fine-frequency searching using predictive interference analysis. The automated system features an RF receiver and transmitter, a control system, and antennas. Trials are run with conducted and radiated emissions and conducted and radiated susceptibility over a frequency range of 0.1-40 GHz with narrow, broad and random broad band noise. The system meets military specifications 1541, 461, and 462.
Iwakata, S.; Rhodes, A. J.; Labzoffsky, N. A.
1972-01-01
The applicability of the immunofluorescence (IF) test to the diagnosis of primary rubella infection was investigated. The test is based on the detection of rubella-specific antibodies in the IgM fraction of immunoglobulins. The results indicate the usefulness of the IF test for the diagnosis of primary rubella infection on a single serum specimen collected at a proper time. The test is also of value in the differentiation of primary infection from reinfection, since in reinfection no rubella-specific antibodies are found in the IgM fraction. The test is also valuable for the detection of fetal infection in utero since the persistence of IgM antibodies in pregnant women is indicative of fetal infection. PMID:4551395
Cheng, Jinxia; Zeng, Jing; Liu, Li; Wei, Haiyan; Zhao, Xiaojuan; Zhang, Ximeng; Zhang, Lei; Zhang, Haiyu
2014-02-01
A novel method of Nano-Immunomagnetic Separation (Nano-IMS) plus Real-time PCR was established for detecting Vibrio cholerae. The Nano-Immunomagnetic Beads were created by using the monoclonal antibody of Vibrio cholerae, which was named Nano-IMB-Vc. Nano-IMB-Vc has specific adsorption of Vibrio cholerae, combined with Real-time PCR technology, a method for rapid detection of Vibrio cholerae was established. The capture specificity of Nano-IMB-Vc was tested by using 15 bacteria strains. The specificity of Real-time PCR method was tested by using 102 targets and 101 non-targets bacteria strains. The sensitivity of Nano-IMS plus Real-time PCR were tested in pure culture and in artificial samples and compared with NMKL No.156. The capture ratio of Nano-IMB-Vc was reached 70.2% at the level of 10(3) CFU/ml. In pure culture, the sensitivity of Nano-IMS plus Real-time PCR was reached at 5.4×10(2) CFU/ml. The specific of Real-time PCR method was tested by using 102 targets and 101 non-targets bacteria. The results showed that 102 strains of Vibrio cholerae test results were all positive, and the rest of the 101 strains of non-target bacteria test results were negative. No cross-reaction was founded. Add 1 CFU vibrio cholerae per 25 g sample, it could be detect with Nano-IMS plus Real-time PCR method after 8 hours enrichment. The Nano-IMS plus Real-time PCR method of Vibrio cholerae established in this study has good specificity and sensitivity, which could be applied to the rapid detection of Vibrio cholerae.
Sekulic, Damir; Pehar, Miran; Krolo, Ante; Spasic, Miodrag; Uljevic, Ognjen; Calleja-González, Julio; Sattler, Tine
2017-08-01
Sekulic, D, Pehar, M, Krolo, A, Spasic, M, Uljevic, O, Calleja-González, J, and Sattler, T. Evaluation of basketball-specific agility: applicability of preplanned and nonplanned agility performances for differentiating playing positions and playing levels. J Strength Cond Res 31(8): 2278-2288, 2017-The importance of agility in basketball is well known, but there is an evident lack of studies examining basketball-specific agility performances in high-level players. The aim of this study was to determine the reliability and discriminative validity of 1 standard agility test (test of preplanned agility [change-of-direction speed] over T course, T-TEST), and 4 newly developed basketball-specific agility tests, in defining playing positions and performance levels in basketball. The study comprised 110 high-level male basketball players (height: 194.92 ± 8.09 cm; body mass: 89.33 ± 10.91 kg; age: 21.58 ± 3.92 years). The variables included playing position (Guard, Forward, Center), performance level (first division vs. second division), anthropometrics (body height, body mass, and percentage of body fat), T-TEST, nonplanned basketball agility test performed on dominant (BBAGILdom) and nondominant sides (BBAGILnond), and a preplanned (change-of-direction speed) basketball agility test performed on dominant (BBCODSdom) and nondominant sides (BBCODSnond). The reliability of agility tests was high (intraclass correlation coefficient of 0.81-0.95). Forwards were most successful in the T-TEST (F test: 13.57; p = 0.01). Guards outperformed Centers in BBCODSdom, BBCODSndom, BBAGILdom, and BBAGILnond (F test: 5.06, p = 0.01; 6.57, 0.01; 6.26, 0.01; 3.37, 0.04, respectively). First division Guards achieved better results than second division Guards in BBCODSdom (t: 2.55; p = 0.02; moderate effect size differences), BBAGILdom, and BBAGILnond (t: 3.04 and 3.06, respectively; both p = 0.01 and moderate effect size differences). First division Centers outperformed second division Centers in BBAGILdom (t: 2.50; p = 0.02; moderate effect size differences). The developed basketball-specific agility tests are applicable when defining position-specific agility. Both preplanned and nonplanned agilities are important qualities in differentiating between Guards of 2 performance levels. The results confirmed the importance of testing basketball-specific nonplanned agility when evaluating the performance level of Centers.
Sensitivity and specificity of the 3-item memory test in the assessment of post traumatic amnesia.
Andriessen, Teuntje M J C; de Jong, Ben; Jacobs, Bram; van der Werf, Sieberen P; Vos, Pieter E
2009-04-01
To investigate how the type of stimulus (pictures or words) and the method of reproduction (free recall or recognition after a short or a long delay) affect the sensitivity and specificity of a 3-item memory test in the assessment of post traumatic amnesia (PTA). Daily testing was performed in 64 consecutively admitted traumatic brain injured patients, 22 orthopedically injured patients and 26 healthy controls until criteria for resolution of PTA were reached. Subjects were randomly assigned to a test with visual or verbal stimuli. Short delay reproduction was tested after an interval of 3-5 minutes, long delay reproduction was tested after 24 hours. Sensitivity and specificity were calculated over the first 4 test days. The 3-word test showed higher sensitivity than the 3-picture test, while specificity of the two tests was equally high. Free recall was a more effortful task than recognition for both patients and controls. In patients, a longer delay between registration and recall resulted in a significant decrease in the number of items reproduced. Presence of PTA is best assessed with a memory test that incorporates the free recall of words after a long delay.
Low specificity of 2 tetanus rapid tests in Cambodia.
Schlumberger, M; Yvonnet, B; Lesage, G; Tep, B
2015-01-01
Rapid testing for tetanus on serum or blood allows for an immediate evaluation of individual protection against tetanus in developed countries, using a "single step" immunochromatographic technique using tetanus toxoid. The specificity of these tests, compared to the reference method for tetanus, mouse serum neutralization testing, has however never been assessed in these countries, due to the difficulty to perform serum neutralization titration in mice, because of animal testing bioethical regulations. A collection of sera from adult volunteers in Cambodia, living in rural environment, was tested for tetanus antibodies by ELISA in France, and by mouse serum neutralization in Vietnam. This allowed estimating the sensitivity and specificity of 2 rapid tetanus tests, available on the market: TQS™ and Tetanotop™. The sensitivity of these tests was adequate, compared to mice serum neutralization test, for a test threshold of 0.01 IU/mL, (100% for TQS™, 91% for Tetanotop™), but their specificity was very low (1% for TQS™ and 13% for Tetanotop™). The results prove that these rapid tests for the assessment of individual protection against tetanus should not be used in the adult rural Cambodian population. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Detection and differentiation of the six Brucella species by polymerase chain reaction.
Sifuentes-Rincón, A. M.; Revol, A.; Barrera-Saldaña, H. A.
1997-01-01
BACKGROUND: Brucelosis is a severe acute febrile disease caused by bacteria of the genus Brucella. Its current diagnosis is based on clinical observations that may be complemented by serology and microbiological culture tests; however, the former is limited in sensitivity and specificity, the latter is time consuming. To improve brucelosis diagnosis we developed a test which is specific and sensitive and is capable of differentiating the six species of Brucella. MATERIALS AND METHODS: Four primers were designed from B. abortus sequences at the well-conserved Omp2 locus that are able to amplify the DNAs of all six species of Brucella. RESULTS: Our test detected all six species of Brucella. Their differentiation resulted directly from differences in the amplification patterns or was achieved indirectly using a RFLP present in one of the PCR products. The sensitivity and specificity of the new test were then determined; it was applied successfully in confirming the diagnosis of a patient whose clinical history and serology indicated infection with Brucella. CONCLUSIONS: The results make possible the use of a PCR test for Brucella detection and differentiation without relying on the measurement of the antibodies or microorganism culture. Our first results showed that the PCR test can confirm the presence of Brucella in blood samples of infected patients. Images FIG. 2 FIG. 3 FIG. 4 FIG. 5 PMID:9407549
Donating Blood Questions and Answers
... isolated laboratory test results should not be considered equivalent to a history of viral hepatitis. In particular, ... transfusion. This test was intended as a surrogate non-specific test for hepatitis C (formerly called non- ...
Kawano, K; Oumi, K; Ashida, Y; Horiuchi, Y; Mizuno, T
2013-01-01
The aim of the present study was to examine the correlation between the results of lymphocyte proliferative test (LPT) specific to food allergens and allergic skin diseases in dogs. Investigations were performed in 138 dogs with allergic skin diseases diagnosed in a private animal hospital. Of the 138 animals, 97 cases had positive reactions in LPT specific to food allergens. Of these 97 dogs, 67 animals were diagnosed with canine atopic dermatitis (CAD), but 30 dogs did not have IgE antibodies to environmental allergens. As 14 dogs out of 30 animals showed a positive result, 12 dogs underwent elimination diet trial based on the test results and all of them showed improvement in the pruritus score. Therefore, we conclude that LPT is an effective diagnostic test for allergic skin disease. Results of the lymphocyte test are useful in the identification of food allergens for the elimination diet trial.
Schmidt, Dietmar; Bergeron, Christine; Denton, Karin J; Ridder, Ruediger
2011-06-25
The objective of this study was to analyze the diagnostic performance of a newly established immunocytochemical dual-stain protocol, which simultaneously detects p16(INK4a) and Ki-67 expression in cervical cytology samples, for identifying high-grade cervical intraepithelial neoplasia (CIN2+) in women with Papanicolaou (Pap) cytology results categorized as atypical squamous cells of undetermined significance (ASCUS) or low-grade squamous intraepithelial lesions (LSIL). Residual liquid-based cytology material from 776 retrospectively collected ASCUS/LSIL cases that were available from a recent study evaluating p16 cytology and HPV testing were subjected to p16/Ki-67 dual staining. The presence of 1 or more double-immunoreactive cell(s) was regarded as a positive test outcome, irrespective of morphology. Test results were correlated to histology follow-up. Sensitivity of p16/Ki-67 dual-stain cytology for biopsy-confirmed CIN2+ was 92.2% (ASCUS) and 94.2% (LSIL), while specificity rates were 80.6% (ASCUS) and 68.0% (LSIL), respectively. Similar sensitivity/specificity profiles were found for both age groups of women aged <30 years versus women aged ≥30 years. Dual-stain cytology showed comparable sensitivity, but significantly higher specificity, when compared with human papillomavirus (HPV) testing. The results of this study show that p16/Ki-67 dual-stain cytology provided a high sensitivity for the detection of underlying CIN2+ in women with ASCUS or LSIL Pap cytology results, comparable to the rates previously reported for HPV testing and p16 single-stain cytology. However, the specificity of this morphology-independent interpretation of p16/Ki-67 dual-stain cytology testing was further improved compared with the earlier p16 single-stain cytology approach, which required morphology interpretation, and it is significantly higher when compared with HPV testing. Copyright © 2011 American Cancer Society.
Korošec, Peter; Šilar, Mira; Eržen, Renato; Čelesnik, Nina; Bajrović, Nissera; Zidarn, Mihaela; Košnik, Mitja
2013-01-01
Previous reports suggest the usefulness of basophil activation testing (BAT) in Hymenoptera-allergic patients with negative venom-specific IgE antibodies. We sought to evaluate the diagnostic utility of this testing in a routine clinical laboratory setting. Twenty-one patients with anaphylactic reactions to Hymenoptera sting (median grade III) and negative venom-specific IgE were routinely and prospectively tested with BAT. We were able to diagnose 81% (17 of 21) of patients with BAT and 57% (12 of 21) with intradermal skin testing. Three wasp venom-allergic patients showed IgE positivity to rVes v 5. Four patients (19%) were negative for all tests. In the case of double-positive BAT, the culprit insect correlated with the venom that induced a significantly higher basophil response. BAT allows the identification of severe Hymenoptera-allergic patients with negative specific IgE and skin tests. The routine use of this cellular test should facilitate prescription of venom immunotherapy in complex cases with inconclusive diagnostic results. Copyright © 2013 S. Karger AG, Basel.
Praud, Anne; Champion, Jean-Luc; Corde, Yannick; Drapeau, Antoine; Meyer, Laurence; Garin-Bastuji, Bruno
2012-07-09
Brucella ovis causes an infectious disease responsible for infertility and subsequent economic losses in sheep production. The standard serological test to detect B. ovis infection in rams is the complement fixation test (CFT), which has imperfect sensitivity and specificity in addition to technical drawbacks. Other available tests include the indirect enzyme-linked immunosorbent assays (I-ELISA) but no I-ELISA kit has been fully evaluated.The study aimed to compare an I-ELISA kit and the standard CFT. Our study was carried out on serum samples from 4599 rams from the South of France where the disease is enzootic. A Bayesian approach was used to estimate tests characteristics (diagnostic sensitivity, Se and diagnostic specificity, Sp). The tests were then studied together in order to optimise testing strategies to detect B. ovis. After optimising the cut-off values in order to avoid doubtful results without deteriorating the concordance between the results of the two tests, the I-ELISA appeared to be slightly more sensitive than CFT (Se I-ELISA=0.917 [0.822; 0.992], 95% Credibility Interval (CrI) compared to Se CFT=0.860 [0.740; 0.967], 95% CrI). However, CFT was slightly more specific than I-ELISA (Sp CFT=0.988 [0.947; 1.0], 95% CrI) compared to Sp I-ELISA =0.952 [0.901; 1.0], 95% CrI).The tests were then associated with two different interpretation schemes. The series association increased the specificity of screening and could be used for pre-movement testing in rams from uninfected flocks. The parallel association increased sequence sensitivity, thus appearing more suitable for eradicating the disease in infected flocks. The high sensitivity and acceptable specificity of this I-ELISA kit support its potential interest to avoid the limitations of CFT. The two tests could also be used together or combined with other diagnostic methods such as semen culture to improve the testing strategy. The choice of test sequence and interpretation criteria depends on the epidemiological context, screening objectives and the financial and practical constraints.
Yugué, Itaru; Okada, Seiji; Maeda, Takeshi; Ueta, Takayoshi; Shiba, Keiichiro
2018-04-01
A retrospective study. Precise classification of the neurological state of patients with acute cervical spinal cord injury (CSCI) can be challenging. This study proposed a useful and simple clinical method to help classify patients with incomplete CSCI. Spinal Injuries Centre, Japan. The sensitivity and specificity of the 'knee-up test' were evaluated in patients with acute CSCI classified as American Spinal Injury Association Impairment Scale (AIS) C or D. The result is positive if the patient can lift the knee in one or both legs to an upright position, whereas the result is negative if the patient is unable to lift the knee in either leg to an upright position. The AIS of these patients was classified according to a strict computerised algorithm designed by Walden et al., and the knee-up test was tested by non-expert examiners. Among the 200 patients, 95 and 105 were classified as AIS C and AIS D, respectively. Overall, 126 and 74 patients demonstrated positive and negative results, respectively, when evaluated using the knee-up test. A total of 104 patients with positive results and 73 patients with negative results were classified as AIS D and AIS C, respectively. The sensitivity, specificity, positive predictive and negative predictive values of this test for all patients were 99.1, 76.8, 82.5 and 98.7, respectively. The knee-up test may allow easy and highly accurate estimation, without the need for special skills, of AIS classification for patients with incomplete CSCI.
Shtessel, Maria; Lobell, Elizabeth; Hudes, Golda; Rosenstreich, David; de Vos, Gabriele
2017-01-01
Background: Allergists commonly perform intradermal skin testing (IDST) after negative skin-prick testing (SPT) to comprehensively diagnose environmental allergic sensitization. However, with the availability of modern methods to detect serum-specific immunoglobulin E (ssIgE), it is unclear if ssIgE testing could substitute for IDST. Objective: To determine the efficacy of ssIgE testing and IDST when added to SPT in diagnosing environmental allergic sensitizations. Methods: SPT, IDST, and ssIgE testing to nine common environmental allergens were analyzed in 75 patients with oculonasal symptoms who presented to our allergy clinics in the Bronx, New York, between January 2014 and May 2015. Results: A total of 651 SPT and 499 ssIgE tests were independently performed and revealed 162 (25%) and 127 (25%) sensitizations, respectively. When SPT results were negative, IDST results revealed 108 of 452 additional sensitizations (24%). In contrast, when SPT results were negative, ssIgE test results only revealed 9% additional sensitizations. When both SPT and IDST results were negative, ssIgE testing only detected 3% of additional sensitizations, and ssIgE levels were typically low in these cases (median, 1.25 kU/L; range, 0.357–4.47 kU/L). When both SPT and ssIgE test results were negative, IDST results detected 15% additional sensitizations. Conclusion: IDST detected more additional environmental sensitizations compared with ssIgE testing. IDST, therefore, may be useful when the SPT and/or ssIgE testing results were negative, but the exposure history indicated relevant allergic sensitization. Serology added only a little more information if both SPT and IDST results were negative but may be useful in combination with SPT if IDST cannot be performed. PMID:28583228
The Variation Test and Extraction Equipment to Optimum Asphalt by Using Gasoline Solvent
NASA Astrophysics Data System (ADS)
Soehardi, Fitridawati
2017-12-01
Based on the Binamarga Specification 2010 at third revision, the extraction test should be carried out using the specimen from the loose asphalt mixture extracted from the back of the finisher bitumen machine. The purpose of this research is to find out the result of pretest and posttest extraction asphalt content. The Extraction test using two equipment, they are Soklet and Centrifuge. The specimens was used AMP, Asphalt Finisher and Core, which involved gasoline solvent. Based on the asphalt level extraction test results, the appropriate equipment was used centrifuge with the level accuracy as requirement of Binamarga Specification 2010 at third revision and the level of ease used as equipment in the field study. The asphalt content obtained for AMP 5,51%, Asphalt Finisher5,46% and Core 5.34%. As for the socket asphalt content obtained is AMP 5.55%, Asphalt Finisher 5.50% and Core core 5. 41%. The extract test value of asphalt content decreased, so it can be formulated KA JMF
Clinical Evaluation of a Loop-Mediated Amplification Kit for Diagnosis of Imported Malaria
Polley, Spencer D.; González, Iveth J.; Mohamed, Deqa; Daly, Rosemarie; Bowers, Kathy; Watson, Julie; Mewse, Emma; Armstrong, Margaret; Gray, Christen; Perkins, Mark D.; Bell, David; Kanda, Hidetoshi; Tomita, Norihiro; Kubota, Yutaka; Mori, Yasuyoshi; Chiodini, Peter L.; Sutherland, Colin J.
2013-01-01
Background. Diagnosis of malaria relies on parasite detection by microscopy or antigen detection; both fail to detect low-density infections. New tests providing rapid, sensitive diagnosis with minimal need for training would enhance both malaria diagnosis and malaria control activities. We determined the diagnostic accuracy of a new loop-mediated amplification (LAMP) kit in febrile returned travelers. Methods. The kit was evaluated in sequential blood samples from returned travelers sent for pathogen testing to a specialist parasitology laboratory. Microscopy was performed, and then malaria LAMP was performed using Plasmodium genus and Plasmodium falciparum–specific tests in parallel. Nested polymerase chain reaction (PCR) was performed on all samples as the reference standard. Primary outcome measures for diagnostic accuracy were sensitivity and specificity of LAMP results, compared with those of nested PCR. Results. A total of 705 samples were tested in the primary analysis. Sensitivity and specificity were 98.4% and 98.1%, respectively, for the LAMP P. falciparum primers and 97.0% and 99.2%, respectively, for the Plasmodium genus primers. Post hoc repeat PCR analysis of all 15 tests with discrepant results resolved 4 results in favor of LAMP, suggesting that the primary analysis had underestimated diagnostic accuracy. Conclusions. Malaria LAMP had a diagnostic accuracy similar to that of nested PCR, with a greatly reduced time to result, and was superior to expert microscopy. PMID:23633403
Comparison of Various Methods in the Diagnosis of Entamoeba histolytica in Stool and Serum Specimens
Uslu, Hakan; Aktas, Osman; Uyanik, Muhammet Hamidullah
2016-01-01
Objective: Entamoeba histolytica is indistinguishable from Entamoeba dispar in direct microscopic examination. A definitive diagnosis of E. histolytica is important in terms of the treatment of the patient and to avoid unnecessary costs. This study’s aim is to determine the prevalence of E. histolytica and to make a comparison of the different diagnostic tests in the patients specimens defined as E. histolytica/E. dispar infection. Materials and Methods: Faecal and serum specimens of 90 patients defined as E. histolytica/E. dispar with microscopy (wet mount examination with 0.85% saline and Lugol’s iodine) were examined. Stool samples were examined by trichrome staining for trophozoites and cysts and by immunoassay methods for specific adhesin antigens (Wampole ® E. histolytica II antigen testing) and for specific serine-rich 30 kD membrane protein (Serazym® E. histolytica antigen testing). Anti-E. histolytica antibodies were investigated using a latex slide test and indirect hemagglutination methods in serum specimens. Results: Presence of E. histolytica was not confirmed in 31.1% cases with trichrome staining, 62.2% of the Wampole antigen test, 64.4%, of the Serazym antigen test, 73.3% of the indirect hemagglutination test and 75.6%. of the latex agglutination. Considering the common results from Wampole and Serazym antigen testing as a reference standard, the specificity/sensitivity is 100/53.85% for trichrome staining, 75.00/98.11% for the latex agglutination test and 78.57/96.77% for the indirect hemagglutination test. Conclusion: It has been shown that investigation of E. histolytica in stools by direct wet-smear microscopy alone can cause significant false positive results. To obtain a reliable diagnosis for E. histolytica and to avoid unnecessary treatment for this parasite, at least one more specific assay, particularly an antigen testing and microscopy, is required. PMID:27551176
42 CFR 410.33 - Independent diagnostic testing facility.
Code of Federal Regulations, 2011 CFR
2011-10-01
... problem and who uses the results in the management of the beneficiary's specific medical problem... the results in the management of the beneficiary's specific medical problem. Nonphysician... SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services...
Marcomichelakis, J; Donaldson, R; Green, J; Joseph, S; Kelly, H B; Taggart, P; Somerville, W
1980-01-01
The value of exercise testing in detecting myocardial ischaemia resulting from coronary atheroma remains controversial. In order to increase the reliability of exercise testing, all its components (asymptomatic, haemodynamic, and electrocardiographic) have been scrutinised. In this study, concerned only with the electrocardiographic response to exercise, the incorporation of beta-blockade into the standard exercise procedure has improved specificity and predictive value without affecting sensitivity. Fifty patients with anginal pain and 50 asymptomatic subjects with an abnormal electrocardiogram were investigated by exercise testing before and after beta-blockade (oxprenolol). All subjects had coronary arteriograms and left ventriculograms, and the results of exercise testing were related to the presence or absence of obstructive coronary artery disease. Possible causes of false positive exercise tests were eliminated by echocardiography. Though beta-blockade was unreliable in distinguishing ischaemic from non-ischaemic resting electrocardiograms, it eliminated all the false positive electrocardiographic responses to exercise in both groups and did not abolish any of the true positive electrocardiographic responses. Thus, specificity and predictive value were improved without reduction in sensitivity. This technique may not necessarily be applicable to other groups of patients or to a random population, but the results of this study suggest it will be a useful additional routine procedure in the investigation of coronary heart disease. PMID:7437172
Merging separately established stimulus classes with outcome-specific reinforcement.
Johnson, Cammarie; Meleshkevich, Olga; Dube, William V
2014-01-01
This study extended previous research on equivalence relations established with outcome-specific reinforcers to include the merger of separately established stimulus classes. Participants were four adults. Conditional discriminations AC and BC were trained first. Correct selections of C1 (C2, or C3) in the presence of A1 or B1 (A2 or B2, or A3 or B3) were followed by red (blue, or white) tokens; tokens were exchanged for value added to three participant-selected gift cards. Outcomes on equivalence tests for three-member classes ABC were positive. DF and EF were trained with the same reinforcing consequences, and tests were positive for three-member classes DEF. Results of class merger tests with combinations of stimuli from the ABC and DEF classes (AD, FB, etc.) were immediately positive for two participants, demonstrating six-member classes ABCDEF with reinforcers as nodes. Merger tests for a third participant were initially negative but became positive after brief exposure to unreinforced probe trials with reinforcers as comparison stimuli. Following class merger, tests for matching the reinforcers to samples and comparisons were also positive. Class-merger test results were negative for a fourth participant. The results provide the first demonstration of eight-member equivalence classes including two outcome-specific conditioned reinforcing stimuli. © Society for the Experimental Analysis of Behavior.
Detection and differentiation of the six Brucella species by polymerase chain reaction.
Sifuentes-Rincón, A M; Revol, A; Barrera-Saldaña, H A
1997-11-01
Brucelosis is a severe acute febrile disease caused by bacteria of the genus Brucella. Its current diagnosis is based on clinical observations that may be complemented by serology and microbiological culture tests; however, the former is limited in sensitivity and specificity, the latter is time consuming. To improve brucelosis diagnosis we developed a test which is specific and sensitive and is capable of differentiating the six species of Brucella. Four primers were designed from B. abortus sequences at the well-conserved Omp2 locus that are able to amplify the DNAs of all six species of Brucella. Our test detected all six species of Brucella. Their differentiation resulted directly from differences in the amplification patterns or was achieved indirectly using a RFLP present in one of the PCR products. The sensitivity and specificity of the new test were then determined; it was applied successfully in confirming the diagnosis of a patient whose clinical history and serology indicated infection with Brucella. The results make possible the use of a PCR test for Brucella detection and differentiation without relying on the measurement of the antibodies or microorganism culture. Our first results showed that the PCR test can confirm the presence of Brucella in blood samples of infected patients.
Evaluation of the LDBIO point of care test for the combined detection of toxoplasmic IgG and IgM.
Chapey, Emmanuelle; Wallon, Martine; Peyron, François
2017-01-01
The toxoplasma ICT IgG-IgM rapid diagnostic test for the simultaneous detection of specific toxoplasmic immunoglobulin (Ig) G and IgM was compared with the Architect fully automated chemiluminescence test. Four hundred sera were included, among which 248 scored negative in Architect. The cassettes were easily read with the naked eye. Diagnostic sensitivity and specificity were 97% and 96%, respectively. The test scored 8 false-positive IgG and yielded negative results in 3 sera displaying unspecific IgM in Architect. The LDBIO appears to be a reliable first line test, although the false-positive results for IgG deserve further investigation. Such an easily performed test could be used advantageously for screening for toxoplasmosis in pregnant women. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brainard, E.L.
1978-04-25
Results are presented of acceptance tests conducted on the Alternator Stator, S/N 002, for the Kilowatt Isotope Power System. These results show that the Alternator Stator, S/N 002 for the Kilowatt Isotope Power System has satisfactorily completed the testing set forth within Sundstrand Test Specification 2538. Test requirements of TS 2538 were extracted from the Kilowatt Isotope Power System, and Phase I Test Plan.
Panneum, S; Rukkwamsuk, T
2017-03-01
For preventive and control strategies of Caprine Arthritis Encephalitis Virus (CAEV) infection in dairy goats, performance of the available diagnostic tests was described as one of the most important and necessary aspects. The study aimed at evaluating the diagnostic test performance, including PCR, ELISA and viral culture, for CAEV infection in dairy goats in Thailand. Blood samples of 29 dairy goats from five low- to medium-prevalence herds and one very low-prevalence herd were collected for PCR and ELISA methods. The performance of these two diagnostic methods was evaluated by comparing with cytopathic effects (CPE) in the co-cultivation of CAEV and primary synovial cells. Results indicated that sensitivity, specificity were, respectively, 69.6%, 100%, for PCR; and 95.7%, 83.3% for ELISA. The PCR assay tended to have lower sensitivity and higher specificity than ELISA. When multiple tests were applied, parallel testing provided sensitivity and specificity of 98.7% and 83.3%, while series testing showed sensitivity and specificity of 66.6% and 100% respectively. These results indicated that combination of ELISA and PCR provided some advantages and possibly offered optimal methods to detect CAEV-infected goats. Kappa value of the agreement between PCR and ELISA test was 0.34, indicating fair agreement. Regarding the possibility of antigenic variation between CAEV strains used in both PCR and ELISA assays, the actual circulating CAEV strain should be reviewed in order to develop and enhance the diagnostic tests using the CAE viral antigens derived from specific local strains of Thailand.
Keskin, Ozlem; Tuncer, Ayfer; Adalioglu, Gonul; Sekerel, Bulent E; Sackesen, Cansin; Kalayci, Omer
2005-05-01
Information on the utility of atopy patch testing (APT) in the diagnosis of food allergy is derived from studies of children with atopic dermatitis. To evaluate the usefulness of APT in the diagnosis of cow's milk allergy (CMA) and to determine interleukin 4 and interferon-gamma production by peripheral blood mononuclear cells. Thirty-seven children (median age, 11 months) with suspected CMA who had a variety of symptoms that involved many organ systems were evaluated using double-blind placebo-controlled food challenges (DBPCFCs), and the performances of milk specific IgE, skin prick testing (SPT), and APT were determined. To search for a possible relationship between the diagnostic tests and the TH1/TH2 immune response, we measured interferon-gamma and interleukin 4 levels in the supernatants of peripheral blood mononuclear cell cultures. Seventeen children with positive DBPCFC results and 6 with a history of anaphylaxis were diagnosed as having CMA. The combined use of APT and SPT had a sensitivity of 100% and a negative predictive value of 100% but a specificity of 50% and a positive predictive value of 76%. The addition of milk specific IgE assays to APT and SPT did not improve these values. Pattern of cytokine secretion was not associated with APT positivity or a specific response to DBPCFC. Atopy patch testing may be a useful adjunct to SPT in excluding CMA in children who have allergic manifestations other than atopic dermatitis. However, DBPCFCs are still necessary in the presence of positive test results.
1994-08-01
version of the MIL SPEC, MIL - F - 24385 Rev. F’ 3. Figure 1 shows the results of the "modeling" experiments. This shows that, for a control time of 60...the military specification, MiL - F - 24385 ’. It was noted in the Background Section that the FAA does not have specific test criteria for foam agents, The...SPECIFICATION TESTS FOR FOAM Type of Foam_ United States/North America UL 162 All types MIL - F - 24385 A,14FT OF 555 Protein 2?GP74 (Canada) AFFF L-urope
Spector, Paul E.
2016-01-01
Background Safety climate, violence prevention climate, and civility climate were independently developed and linked to domain-specific workplace hazards, although all three were designed to promote the physical and psychological safety of workers. Purpose To test domain specificity between conceptually related workplace climates and relevant workplace hazards. Methods Data were collected from 368 persons employed in various industries and descriptive statistics were calculated for all study variables. Correlational and relative weights analyses were used to test for domain specificity. Results The three climate domains were similarly predictive of most workplace hazards, regardless of domain specificity. Discussion This study suggests that the three climate domains share a common higher order construct that may predict relevant workplace hazards better than any of the scales alone. PMID:27110930
Van Der Pol, Barbara; Martin, David H.; Schachter, Julius; Quinn, Thomas C.; Gaydos, Charlotte A.; Jones, Robert B.; Crotchfelt, Kimberly; Moncada, Jeanne; Jungkind, D.; Turner, Buffy; Peyton, Cynthia; Kelly, James F.; Weiss, Judith B.; Rosenstraus, Maurice
2001-01-01
The COBAS AMPLICOR CT/NG test for Neisseria gonorrhoeae cross-reacts with certain strains of nonpathogenic Neisseria species. In some strains, the target sequence is identical to that of N. gonorrhoeae, whereas other strains have a small number of mismatches within the regions recognized by the primers or probe used in the COBAS AMPLICOR NG test. These cross-reactive strains are occasionally present in urogenital specimens, causing false-positive results in the COBAS AMPLICOR NG test. Analysis of the data generated in a large multicenter clinical trial showed that 2.9% of the specimens gave signals between A660s of 0.2 and 3.5 but that one-half of these equivocal specimens did not contain N. gonorrhoeae. Most of these equivocal specimens were correctly classified as true positive or true negative by retesting in duplicate and defining a PCR-positive result as two of three results with an A660 of ≥2.0. If specimens had been classified as positive or negative based on a single test result using a cutoff of an A660 of 0.2, specificity would have ranged from 96.2 to 98.9% depending on specimen type, sex, and presence of symptoms. By employing the equivocal zone-retesting algorithm, specificity increased to 98.6 to 99.9% with little effect (0.1 to 4.9% decrease) on sensitivity in most specimen types, enabling the test to achieve a positive predictive value of at least 90% in populations with a prevalence of 4% or higher. In lower-prevalence populations, the test could be used to screen for presumptive infections that would have to be confirmed by an independent test. PMID:11526134
López, Lissett; Venteo, Angel; Aguirre, Enara; García, Marga; Rodríguez, Majosé; Amusátegui, Inmaculada; Tesouro, Miguel A; Vela, Carmen; Sainz, Angel; Rueda, Paloma
2007-11-01
An indirect enzyme-linked immunosorbent assay (ELISA) based on baculovirus recombinant P30 protein of Ehrlichia canis and the 1BH4 anticanine IgG monoclonal antibody was developed and evaluated by examining a panel of 98 positive and 157 negative sera using the indirect fluorescent antibody (IFA) test as the reference technique. The P30-based ELISA appeared to be sensitive and specific (77.55% and 95.54%, respectively) when qualitative results (positive/negative) were compared with those of the IFA test; the coefficient of correlation (R) between the 2 tests was 0.833. Furthermore, it was possible to establish a mathematical formula for use in comparing the results of both techniques. These results indicate that recombinant P30 antigen-based ELISA is a suitable alternative of the IFA test for simple, consistent, and rapid serodiagnosis of canine ehrlichiosis. Moreover, the use of this recombinant protein as antigen offers a great advantage for antigen preparation in comparison with other techniques in which the whole E. canis organism is used as antigen.
Gonzales, J L; Loza, A; Chacon, E
2006-03-15
There are several T. vivax specific primers developed for PCR diagnosis. Most of these primers were validated under different DNA extraction methods and study designs leading to heterogeneity of results. The objective of the present study was to validate PCR as a diagnostic test for T. vivax trypanosomosis by means of determining the test sensitivity of different published specific primers with different sample preparations. Four different DNA extraction methods were used to test the sensitivity of PCR with four different primer sets. DNA was extracted directly from whole blood samples, blood dried on filter papers or blood dried on FTA cards. The results showed that the sensitivity of PCR with each primer set was highly dependant of the sample preparation and DNA extraction method. The highest sensitivities for all the primers tested were determined using DNA extracted from whole blood samples, while the lowest sensitivities were obtained when DNA was extracted from filter paper preparations. To conclude, the obtained results are discussed and a protocol for diagnosis and surveillance for T. vivax trypanosomosis is recommended.
Extinguishing agent for magnesium fire, phases 5 and 6
NASA Astrophysics Data System (ADS)
Beeson, H. D.; Tapscott, R. E.; Mason, B. E.
1987-07-01
This report documents the validation testing of the extinguishing system for metal fires developed as part of Phases 1 to 4. The results of this validation testing form the basis of information from which draft military specifications necessary to procure the agent and the agent delivery system may be developed. The developed system was tested against a variety of large-scale metal fire scenarios and the capabilities of the system were assessed. In addition the response of the system to storage and to changes in ambient conditions was tested. Results of this testing revealed that the developed system represented a reliable metal fire extinguishing system that could control and extinguish very large metal fires. The specifications developed for the agent and for the delivery system are discussed in detail.
Bruner, L H; Carr, G J; Harbell, J W; Curren, R D
2002-06-01
An approach commonly used to measure new toxicity test method (NTM) performance in validation studies is to divide toxicity results into positive and negative classifications, and the identify true positive (TP), true negative (TN), false positive (FP) and false negative (FN) results. After this step is completed, the contingent probability statistics (CPS), sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) are calculated. Although these statistics are widely used and often the only statistics used to assess the performance of toxicity test methods, there is little specific guidance in the validation literature on what values for these statistics indicate adequate performance. The purpose of this study was to begin developing data-based answers to this question by characterizing the CPS obtained from an NTM whose data have a completely random association with a reference test method (RTM). Determining the CPS of this worst-case scenario is useful because it provides a lower baseline from which the performance of an NTM can be judged in future validation studies. It also provides an indication of relationships in the CPS that help identify random or near-random relationships in the data. The results from this study of randomly associated tests show that the values obtained for the statistics vary significantly depending on the cut-offs chosen, that high values can be obtained for individual statistics, and that the different measures cannot be considered independently when evaluating the performance of an NTM. When the association between results of an NTM and RTM is random the sum of the complementary pairs of statistics (sensitivity + specificity, NPV + PPV) is approximately 1, and the prevalence (i.e., the proportion of toxic chemicals in the population of chemicals) and PPV are equal. Given that combinations of high sensitivity-low specificity or low specificity-high sensitivity (i.e., the sum of the sensitivity and specificity equal to approximately 1) indicate lack of predictive capacity, an NTM having these performance characteristics should be considered no better for predicting toxicity than by chance alone.
Shastri, Surendra S; Dinshaw, Ketayun; Amin, Geetanjali; Goswami, Smriti; Patil, Sharmila; Chinoy, Roshini; Kane, S; Kelkar, Rohini; Muwonge, Richard; Mahé, Cédric; Ajit, Dulhan; Sankaranarayanan, R
2005-03-01
Naked eye visual inspection with acetic acid (VIA), magnified VIA (VIAM), visual inspection with Lugol's iodine (VILI), cytology and human papillomavirus (HPV) testing were evaluated as screening methods for the detection of high-grade squamous intraepithelial lesions (HSIL) of the uterine cervix in a cross-sectional study in Mumbai, India. Cytology, HPV testing, VIA, VIAM and VILI were carried out concurrently for 4039 women aged 30-65 years. All women were investigated with colposcopy and biopsies were taken from 939 women who had colposcopic abnormalities. The reference standard for final disease status was histology or negative colposcopy. The presence of HSIL was confirmed in 57 women (1.4%). The test characteristics for each method were calculated using standard formulae. The sensitivities of cytology, HPV testing, VIA, VIAM and VILI were 57.4%, 62.0%, 59.7%, 64.9%, and 75.4%, respectively (differences were not statistically significant). The specificities were 98.6%, 93.5%, 88.4%, 86.3%, and 84.3%, respectively. Adding a visual test to cytology or HPV testing in parallel combination resulted in a substantial increase in sensitivity, with a moderate decrease in specificity. The parallel combination of VILI and HPV testing resulted in a sensitivity of 92.0% and a specificity of 79.9%. As a single test, cytology had the best balance of sensitivity and specificity. Visual tests are promising in low-resource settings, such as India. The use of both VIA and VILI may be considered where good quality cytology or HPV testing are not feasible. The sensitivity of cytology and HPV testing increased significantly when combined with VIA or VILI.
Sadaka, Carmen; Kanellos, Theo; Guardabassi, Luca; Boucher, Joseph; Watts, Jeffrey L
2017-01-01
Antimicrobial susceptibility test results for trimethoprim-sulfadiazine with Streptococcus equi subspecies are interpreted based on human data for trimethoprim-sulfamethoxazole. The veterinary-specific data generated in this study support a single breakpoint for testing trimethoprim-sulfamethoxazole and/or trimethoprim-sulfadiazine with S. equi This study indicates trimethoprim-sulfamethoxazole as an acceptable surrogate for trimethoprim-sulfadiazine with S. equi. Copyright © 2016 Sadaka et al.
Kanellos, Theo; Guardabassi, Luca; Boucher, Joseph
2016-01-01
ABSTRACT Antimicrobial susceptibility test results for trimethoprim-sulfadiazine with Streptococcus equi subspecies are interpreted based on human data for trimethoprim-sulfamethoxazole. The veterinary-specific data generated in this study support a single breakpoint for testing trimethoprim-sulfamethoxazole and/or trimethoprim-sulfadiazine with S. equi. This study indicates trimethoprim-sulfamethoxazole as an acceptable surrogate for trimethoprim-sulfadiazine with S. equi. PMID:27847375
Misleading biochemical laboratory test results
Nanji, Amin A.
1984-01-01
This article reviews the general and specific factors that interfere with the performance of common biochemical laboratory tests and the interpretation of their results. The clinical status of the patient, drug interactions, and in-vivo and in-vitro biochemical interactions and changes may alter the results obtained from biochemical analysis of blood constituents. Failure to recognize invalid laboratory test results may lead to injudicious and dangerous management of patients. PMID:6375845
False-negative syphilis treponemal enzyme immunoassay results in an HIV-infected case-patient.
Katz, Alan R; Komeya, Alan Y; Tomas, Juval E
2017-06-01
We present a case report of a false-negative syphilis treponemal enzyme immunoassay test result in an HIV-infected male. While treponemal tests are widely considered to be more sensitive and specific than non-treponemal tests, our findings point to potential challenges using the reverse sequence syphilis screening algorithm.
Lee, Sung-Jae; Brooks, Ronald; Bolan, Robert K.; Flynn, Risa
2013-01-01
Men who have sex with men (MSM) in the United States represent a vulnerable population with lower rates of HIV testing. There are various specific attributes of HIV testing that may impact willingness to test (WTT) for HIV. Identifying specific attributes influencing patients’ decisions around WTT for HIV is critical to ensure improved HIV testing uptake. This study examined WTT for HIV by using conjoint analysis, an innovative method for systematically estimating consumer preferences across discrete attributes. WTT for HIV was assessed across eight hypothetical HIV testing scenarios varying across seven dichotomous attributes: location (home vs. clinic), price (free vs. $50), sample collection (finger prick vs. blood), timeliness of results (immediate vs. 1–2 weeks), privacy (anonymous vs. confidential), results given (by phone vs. in-person), and type of counseling (brochure vs. in-person). Seventy-five MSM were recruited from a community based organization providing HIV testing services in Los Angeles to participate in conjoint analysis. WTT for HIV score was based on a 100-point scale. Scores ranged from 32.2 to 80.3 for eight hypothetical HIV testing scenarios. Price of HIV testing (free vs. $50) had the highest impact on WTT (impact score=31.4, SD=29.2, p<.0001), followed by timeliness of results (immediate vs. 1–2 weeks) (impact score=13.9, SD=19.9, p=<.0001) and testing location (home vs. clinic) (impact score=10.3, SD=22.8, p=.0002). Impacts of other HIV testing attributes were not significant. Conjoint analysis method enabled direct assessment of HIV testing preferences and identified specific attributes that significantly impact WTT for HIV among MSM. This method provided empirical evidence to support the potential uptake of the newly FDA-approved over-the-counter HIV home-test kit with immediate results, with cautionary note on the cost of the kit. PMID:23651439
Gauthier, Lauraine; Dortet, Laurent; Naas, Thierry
2017-01-01
Background There is an urgent need for accurate and rapid diagnostic tests to identify carbapenemase producing enterobacteria (CPE). Here, we have evaluated the Carbapenem Inactivation Method (CIM) test to detect CPEs from cultured colonies. Methods A total of 256 enterobacterial isolates were used to evaluate the performance of the CIM in comparison to Carba NP test and molecular detection used a reference method. Ninety three well-characterized isolates (including 29 non-CPE and 63 CPEs of worldwide origin) with decreased susceptibility to at least one carbapenem were used to (i) evaluate the efficacy of CIM test and (ii) to compare it to the Carba NP test. We also tested different carbapenems to determine the best substrate for this test. Finally, the CIM test was then evaluated prospectively against 164 isolates referred to the French National Reference Center (NRC) for Antimicrobial Resistance from may 2016 to july 2016. Results Based on the results of this retrospective study, sensitivity and specificity of the CIM and the Carba NP test were 92.1% and 100%, respectively. We demonstrated that the meropenem was the best substrate to perform the CIM test since sensitivity and specificity were 81.1% and 100% using ertapenem disk, and 100% and 65,6% using imipenem disk, and respectively. Taking in account the results of retrospective and prospective studies, CIM and Carba NP tests have similar sensitivity, specificity, positive predictive value and negative predictive values being 96.3%, 98.9%, 99.0% and 98.4% for the CIM test versus 96.9%, 100%, 100% and 100% for the Carba NP test. Conclusions Our results confirm that the CIM test may be a useful tool for the reliable confirmation of carbapenemase-activity in enterobacterial isolates, especially in clinical microbiological laboratories with limited resources, no trained personnel, and no specialized equipment. PMID:28158310
Ferastraoaru, Denisa; Shtessel, Maria; Lobell, Elizabeth; Hudes, Golda; Rosenstreich, David; de Vos, Gabriele
2017-06-01
Allergists commonly perform intradermal skin testing (IDST) after negative skin-prick testing (SPT) to comprehensively diagnose environmental allergic sensitization. However, with the availability of modern methods to detect serum-specific immunoglobulin E (ssIgE), it is unclear if ssIgE testing could substitute for IDST. To determine the efficacy of ssIgE testing and IDST when added to SPT in diagnosing environmental allergic sensitizations. SPT, IDST, and ssIgE testing to nine common environmental allergens were analyzed in 75 patients with oculonasal symptoms who presented to our allergy clinics in the Bronx, New York, between January 2014 and May 2015. A total of 651 SPT and 499 ssIgE tests were independently performed and revealed 162 (25%) and 127 (25%) sensitizations, respectively. When SPT results were negative, IDST results revealed 108 of 452 additional sensitizations (24%). In contrast, when SPT results were negative, ssIgE test results only revealed 9% additional sensitizations. When both SPT and IDST results were negative, ssIgE testing only detected 3% of additional sensitizations, and ssIgE levels were typically low in these cases (median, 1.25 kU/L; range, 0.357-4.47 kU/L). When both SPT and ssIgE test results were negative, IDST results detected 15% additional sensitizations. IDST detected more additional environmental sensitizations compared with ssIgE testing. IDST, therefore, may be useful when the SPT and/or ssIgE testing results were negative, but the exposure history indicated relevant allergic sensitization. Serology added only a little more information if both SPT and IDST results were negative but may be useful in combination with SPT if IDST cannot be performed.
Physiologic Screening Test for Eating Disorders/Disordered Eating Among Female Collegiate Athletes.
Black, David R.; Larkin, Laurie J.S.; Coster, Daniel C.; Leverenz, Larry J.; Abood, Doris A.
2003-12-01
OBJECTIVE: To develop and evaluate a physiologic screening test specifically designed for collegiate female athletes engaged in athletic competition or highly athletic performances in order to detect eating disorders/disordered eating. No such physiologically based test currently exists. METHODS: Subjects included 148 (84.5%) of 175 volunteer, National Collegiate Athletic Association Division I (n = 92), club (n = 15), and dance team (n = 41) athletes 18 to 25 years old who attended a large, Midwestern university. Participants completed 4 tests: 2 normed for the general population (Eating Disorders Inventory-2 and Bulimia Test-Revised); a new physiologic test, developed and pilot tested by the investigators, called the Physiologic Screening Test; and the Eating Disorder Exam 12.0D, a structured, validated, diagnostic interview used for criterion validity. RESULTS: The 18-item Physiologic Screening Test produced the highest sensitivity (87%) and specificity (78%) and was superior to the Eating Disorders Inventory-2 (sensitivity = 62%, specificity = 74%) and Bulimia Test-Revised (sensitivity = 27%, specificity = 99%). A substantial number (n = 51, 35%) of athletes were classified as eating disordered/disordered eating. CONCLUSIONS: The Physiologic Screening Test should be considered for screening athletes for eating disorders/disordered eating. The Physiologic Screening Test seems to be a viable alternative to existing tests because it is specifically designed for female athletes, it is brief (4 measurements and 14 items), and validity is enhanced and response bias is lessened because the purpose is less obvious, especially when included as part of a mandatory preparticipation examination.
Standardized verification of fuel cycle modeling
Feng, B.; Dixon, B.; Sunny, E.; ...
2016-04-05
A nuclear fuel cycle systems modeling and code-to-code comparison effort was coordinated across multiple national laboratories to verify the tools needed to perform fuel cycle analyses of the transition from a once-through nuclear fuel cycle to a sustainable potential future fuel cycle. For this verification study, a simplified example transition scenario was developed to serve as a test case for the four systems codes involved (DYMOND, VISION, ORION, and MARKAL), each used by a different laboratory participant. In addition, all participants produced spreadsheet solutions for the test case to check all the mass flows and reactor/facility profiles on a year-by-yearmore » basis throughout the simulation period. The test case specifications describe a transition from the current US fleet of light water reactors to a future fleet of sodium-cooled fast reactors that continuously recycle transuranic elements as fuel. After several initial coordinated modeling and calculation attempts, it was revealed that most of the differences in code results were not due to different code algorithms or calculation approaches, but due to different interpretations of the input specifications among the analysts. Therefore, the specifications for the test case itself were iteratively updated to remove ambiguity and to help calibrate interpretations. In addition, a few corrections and modifications were made to the codes as well, which led to excellent agreement between all codes and spreadsheets for this test case. Although no fuel cycle transition analysis codes matched the spreadsheet results exactly, all remaining differences in the results were due to fundamental differences in code structure and/or were thoroughly explained. As a result, the specifications and example results are provided so that they can be used to verify additional codes in the future for such fuel cycle transition scenarios.« less
Wagner, Herbert; Fuchs, Philip X; von Duvillard, Serge P
2018-01-01
Team handball is a dynamic sport game that is played professionally in numerous countries. However, knowledge about training and competition is based mostly on practical experience due to limited scientific studies. Consequently, the aims of our study were to compare specific physiological and biomechanical performance in elite, sub-elite and in non-elite male team handball players. Thirty-six elite, sub-elite and non-elite male team handball players performed a game based performance test, upper-body and lower-body strength tests, 30-m sprint test, counter movement jump test and an incremental treadmill running test. Significant differences (P<0.05) were found for the peak oxygen uptake, heart rate, offense and defense time, jump height and ball velocity during the jump throw in the game based performance test, maximal oxygen uptake in the incremental treadmill running test as well as in maximal leg strength and leg explosive strength in the isometric strength test. Elite male players have an enhanced specific agility, a better throwing performance, a higher team handball specific oxygen uptake and higher leg strength compared to sub-elite and non-elite players. Based on these results we recommend that training in team handball should focus on game based training methods to improve performance in specific agility, endurance and technique.
Peter, S; Lacher, A; Marschal, M; Hölzl, F; Buhl, M; Autenrieth, I; Kaase, M; Willmann, M
2014-07-01
Metallo-beta-lactamase (MBL) production in Pseudomonas aeruginosa is a growing issue across the globe. Fast and reliable diagnostic tools are needed for appropriate implementation of infection control measures. In this study we evaluated the performance of three commercial combined disk tests, two EDTA based in-house combined disk tests and the Carba NP test in comparison to molecular detection of MBL genes on 133 meropenem non-susceptible non-duplicate P. aeruginosa clinical isolates. The meropenem/DPA based commercial KPC + MBL-confirm ID kit (Rosco Diagnostica, Denmark) and the MASTDISCS™ ID carbapenemase (Enterobacteriaceae) detection disc set (MAST Diagnostics, UK) showed sensitivities of 31.1 % and 28.8 % and specificities of 69.3 % and 79.6 %, respectively. The total MBL confirm kit (Rosco Diagnostica, Denmark) contains imipenem/DPA and imipenem/EDTA combination disks. Evaluation of the single disk combinations revealed 84.4 % sensitivity and 81.8 % specificity for the imipenem/DPA assay and 86.7 % sensitivity and 51.1 % specificity for the imipenem/EDTA test. Applying both tests simultaneously resulted in a slightly higher sensitivity of 88.9 % but a lower specificity of 48.9 % when compared to the single tests alone. The Carba NP test showed 93.3 % sensitivity and 96.6 % specificity. All phenotypic combined disk tests lacked either sensitivity or specificity for the detection of MBL in P. aeruginosa. The Carba NP test showed excellent test properties, but suffers from drawbacks in handling and high costs. The optimal diagnostic approach needs to be chosen depending on the epidemiological situation, laboratory resources and availability of molecular confirmation tests.
Comparison of sport-specific and non-specific exercise testing in inline speed skating.
Stangier, Carolin; Abel, Thomas; Mierau, Julia; Gutmann, Boris; Hollmann, Wildor; Struder, Heiko K
2016-04-01
The most effective way to measure exercise performance in inline speed skating (ISS) has yet to be established. Generally most athletes are examined by means of traditional but unspecific cycling (CYC) or running (RUN) testing. The present study investigates whether a sport-specific incremental test in ISS reveals different results. Eight male top level inline speed skaters (age: 30±4 years; 65.4±6.3 mL∙kg-1∙min-1, training: 12-14 h/week) performed three incremental exhaustive tests in a randomized order (ergometer CYC, field RUN, field ISS). During the tests, heart rate (HR), oxygen uptake (V̇O2, energy expenditure (EE) and blood lactate concentration (BLC) were measured. Analysis of variance revealed no significant differences for peak HR (187±9, 191±9, 190±9; P=0.75), BLC (10.9±2.3, 10.8±2.4, 8.5±3.2; P=0.25), V̇O2 (65.4±6.3, 66.8±3.5, 66.4±6.5; P=0.91) and EE (1371±165, 1335±93, 1439±196; P=0.51) between ISS and CYC or RUN test. Similar results appeared for HR and V̇O2 at submaximal intensities (2 and 4 mmol·L-1 BLC; P≥0.05). Small to moderate effect sizes 0.3-0.87 and considerable variability of differences between the exercise modes (mean bias range between 1% and 17% with 95% limits of agreement between 3% and 33%) among submaximal and maximal results limit the comparability of the three tests. Consequently, CYC and RUN tests may be considered as qualified alternatives for a challenging ISS test. However a sport-specific test should be conducted in cases of doubt, or when precision is required (e.g. for elite athletes or scientific studies).
Physical Performance in Elite Male and Female Team Handball Players.
Wagner, Herbert; Fuchs, Patrick; Fusco, Andrea; Fuchs, Philip; Bell, W Jeffrey; Duvillard, Serge P
2018-06-12
Biological differences between men and women are well known; however, literature-addressing knowledge about the influence of sex to specific and general performance in team handball is almost nonexistent. Consequently, the aim of the study was to assess and compare specific and general physical performance in male and female elite team handball players, to determine if the differences are consequential for general compared to specific physical performance characteristics and the relationship between general and specific physical performance. Twelve male and ten female elite team handball players performed a game based performance test, upper- und lower-body strength and power tests, a sprinting test, and an incremental treadmill-running test. Significant differences (P<.05) between male and female players were found for peak oxygen uptake and total running time during the treadmill test, 30m sprinting time, leg extension strength, trunk and shoulder rotation torque, counter movement jump height as well as offense and defense time, ball velocity and jump height in the game based performance test. An interaction (sex × test) was found for time and oxygen uptake and except shoulder rotation torque and ball velocity in females, we found only a low relationship between specific and general physical performance. The results of the study revealed that male players are heavier, taller, faster, stronger, jump higher and have a better aerobic performance. However, female players performed relatively better in the team handball specific tests compared to the general tests. Our findings also suggest that female players should focus more on strength training.
Phase Measurement of Cognitive Impairment Specific to Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Armstrong, Carol L., E-mail: armstrongc@email.chop.edu; Department of Pediatrics, Division of Neuro-Oncology, University of Pennsylvania, School of Medicine, Philadelphia, Pennsylvania; Shera, David M.
Purpose: Memory impairment is an early-delayed effect of radiotherapy (RT). The prospective longitudinal measurement of the cognitive phase effects from RT was conducted on treated and untreated brain tumor patients. The study design investigated semantic vs. perceptual and visual vs. verbal memory to determine the most disease-specific measure of RT-related changes and understanding of the neurotoxicity from RT to the brain. Methods and Materials: Tests of memory that had previously shown RT-related phasic changes were compared with experimental tests of memory to test hypotheses about cognition targeted to the neural toxicity of RT. The results from 41 irradiated and 29more » nonirradiated patients with low-grade, supratentorial tumors were analyzed. The methods controlled for comorbid white matter risk, recurrence, interval after treatment, and age (18-69 years). The effects were examined before RT and at three points after RT to 1 year using a mixed effects model that included interval, group, surgical status, medication use, practice, and individual random effects. Four new tests of memory and other candidate cognitive tests were investigated, and a post hoc analysis of a comprehensive battery of tests was performed to identify the cognitive processes most specific to RT. Results: The RT effects on memory were identified in the treated group only; among the new tests of memory and the complete neurocognitive battery, the RT effects were significant only for delayed recall (p < 0.009) and interval to recognize (p < 0.002). Tumor location was not related to the treatment effect. Memory decline was specific to retrieval of semantic memories; a double dissociation of semantic from perceptual visual memory was demonstrated in the RT group. Conclusions: These results implicate memory dependent on the semantic cortex and the hippocampal memory system. A cognitive measurement that is brief but specific to neural mechanisms is effective and feasible for studies of RT damage.« less
Comparison of five methods of malaria detection in the outpatient setting.
Lema, O E; Carter, J Y; Nagelkerke, N; Wangai, M W; Kitenge, P; Gikunda, S M; Arube, P A; Munafu, C G; Materu, S F; Adhiambo, C A; Mukunza, H K
1999-02-01
In eastern Africa where 90% of the malaria is due to Plasmodium falciparum, the accuracy of malaria diagnosis at the outpatient level is becoming increasingly important due to problems of drug resistance and use of alternative, costly antimalarial drugs. The quantitative buffy coat (QBC) technique, acridine orange staining with an interference filter system, and the ParaSight-F test have been introduced as alternative methods to conventional microscopy for the diagnosis of malaria. Two hundred thirteen outpatients were tested using these alternative methods and conventional microscopy by five experienced technologists; two were randomly allocated to read the results of each test. Paired results showed the highest level of agreement with the ParaSight-F test (99%), followed by Field stain (92%). The results of the QBC technique showed the least agreement (73%). Using conventional microscopy as the reference standard, the ParaSight-F test had a sensitivity range of 90-92% and a specificity of 99%, staining with acridine orange had a sensitivity range of 77-96% and a specificity range of 81-98% and the QBC technique had a sensitivity range of 88-98% and a specificity range of 58-90%. All microscopic tests showed lower sensitivities (as low as 20% using staining with acridine orange) in detecting low parasitemias (< or = 320/microl) than the ParaSight-F test (70%). Due to the high cost of the ParaSight-F test, Field-stained blood films remain the most appropriate method for diagnosis of P. falciparum in eastern Africa. The ParaSight-F test may be used in situations where no trained microscopists are available, or where malaria is strongly suspected and the results of microscopy are negative.
EVOKED POTENTIALS, PHYSIOLOGICAL METHODS WITH HUMAN APPLICATIONS
A number of tests and test batteries have been developed and implemented for detecting potential neurotoxicity in humans. n some cases test results may suggest specific dysfunction. hile tests in laboratory animals are often used to project the potential for adverse health effect...
A Statistical Approach to Establishing Subsystem Environmental Test Specifications
NASA Technical Reports Server (NTRS)
Keegan, W. B.
1974-01-01
Results are presented of a research task to evaluate structural responses at various subsystem mounting locations during spacecraft level test exposures to the environments of mechanical shock, acoustic noise, and random vibration. This statistical evaluation is presented in the form of recommended subsystem test specifications for these three environments as normalized to a reference set of spacecraft test levels and are thus suitable for extrapolation to a set of different spacecraft test levels. The recommendations are dependent upon a subsystem's mounting location in a spacecraft, and information is presented on how to determine this mounting zone for a given subsystem.
Certification of highly complex safety-related systems.
Reinert, D; Schaefer, M
1999-01-01
The BIA has now 15 years of experience with the certification of complex electronic systems for safety-related applications in the machinery sector. Using the example of machining centres this presentation will show the systematic procedure for verifying and validating control systems using Application Specific Integrated Circuits (ASICs) and microcomputers for safety functions. One section will describe the control structure of machining centres with control systems using "integrated safety." A diverse redundant architecture combined with crossmonitoring and forced dynamization is explained. In the main section the steps of the systematic certification procedure are explained showing some results of the certification of drilling machines. Specification reviews, design reviews with test case specification, statistical analysis, and walk-throughs are the analytical measures in the testing process. Systematic tests based on the test case specification, Electro Magnetic Interference (EMI), and environmental testing, and site acceptance tests on the machines are the testing measures for validation. A complex software driven system is always undergoing modification. Most of the changes are not safety-relevant but this has to be proven. A systematic procedure for certifying software modifications is presented in the last section of the paper.
Flori, Pierre; Delaunay, Edouard; Guillerme, Cécile; Charaoui, Sana; Raberin, Hélène; Hafid, Jamal; L'Ollivier, Coralie
2017-01-01
ABSTRACT A study comparing the ICT (immunochromatography technology) Toxoplasma IgG and IgM rapid diagnostic test (LDBio Diagnostics, France) with a fully automated system, Architect, was performed on samples from university hospitals of Marseille and Saint-Etienne. A total of 767 prospective sera and 235 selected sera were collected. The panels were selected to test various IgG and IgM parameters. The reference technique, Toxoplasma IgGII Western blot analysis (LDBio Diagnostics), was used to confirm the IgG results, and commercial kits Platelia Toxo IgM (Bio-Rad) and Toxo-ISAgA (bioMérieux) were used in Saint-Etienne and Marseille, respectively, as the IgM reference techniques. Sensitivity and specificity of the ICT and the Architect IgG assays were compared using a prospective panel. Sensitivity was 100% for the ICT test and 92.1% for Architect (cutoff at 1.6 IU/ml). The low-IgG-titer serum results confirmed that ICT sensitivity was superior to that of Architect. Specificity was 98.7% (ICT) and 99.8% (Architect IgG). The ICT test is also useful for detecting IgM without IgG and is both sensitive (100%) and specific (100%), as it can distinguish nonspecific IgM from specific Toxoplasma IgM. In comparison, IgM sensitivity and specificity on Architect are 96.1% and 99.6%, respectively (cutoff at 0.5 arbitrary units [AU]/ml). To conclude, this new test overcomes the limitations of automated screening techniques, which are not sensitive enough for IgG and lack specificity for IgM (rare IgM false-positive cases). PMID:28954897
Ismael, Alaa Bassuny; Swelum, Ayman Abdel-Aziz; Mostafa, Salama A-H; Alhumiany, Abdel-Rahman A
2016-01-01
Brucellosis, especially caused by Brucella melitensis, is considered the most-widespread zoonosis in the world, particularly in developing countries. This study was planned to develop an accurate test for diagnosis of ovine brucellosis using a specific hot saline extracted soluble Brucella melitensis periplasmic proteins (SBPPs). The efficacy of the latex agglutination test (LAT) using SBPPs compared to the Rose Bengal test (RBT), buffered plate agglutination test (BPAT), serum agglutination test (SAT), and an indirect enzyme-linked immunosorbent assay (i-ELISA) was evaluated in the field diagnosis of ovine brucellosis. The test performance was evaluated by estimating sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), disease prevalence (DP), positive likelihood ratio (PLR), and negative likelihood ratio (NLR) using test agreement and bacteriological culture in 1777 samples. The false-positive result was significantly (P ⩽0.05) lower in LAT than RBT, BPAT, SAT, and i-ELISA. With reference to test agreement, the Se, Sp, PPV, and PLR were highest (P ⩽0.05) in LAT 99.33%, 99.88%, 98.68%, and 827.25%, respectively. With reference to bacteriological culture, the LAT and i-ELISA tests showed a significant difference in Se with SAT. However, no significant difference in specificity was detected. The DP was 8.44% in the five tests. In conclusion, LAT using SBPPs of B. melitensis could be a suitable serodiagnostic field test for ovine brucellosis, with high sensitivity and specificity. PMID:27207442
Ismael, Alaa Bassuny; Swelum, Ayman Abdel-Aziz; Mostafa, Salama A-H; Alhumiany, Abdel-Rahman A
2016-09-01
Brucellosis, especially caused by Brucella melitensis, is considered the most-widespread zoonosis in the world, particularly in developing countries. This study was planned to develop an accurate test for diagnosis of ovine brucellosis using a specific hot saline extracted soluble Brucella melitensis periplasmic proteins (SBPPs). The efficacy of the latex agglutination test (LAT) using SBPPs compared to the Rose Bengal test (RBT), buffered plate agglutination test (BPAT), serum agglutination test (SAT), and an indirect enzyme-linked immunosorbent assay (i-ELISA) was evaluated in the field diagnosis of ovine brucellosis. The test performance was evaluated by estimating sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), disease prevalence (DP), positive likelihood ratio (PLR), and negative likelihood ratio (NLR) using test agreement and bacteriological culture in 1777 samples. The false-positive result was significantly (P ⩽0.05) lower in LAT than RBT, BPAT, SAT, and i-ELISA. With reference to test agreement, the Se, Sp, PPV, and PLR were highest (P ⩽0.05) in LAT 99.33%, 99.88%, 98.68%, and 827.25%, respectively. With reference to bacteriological culture, the LAT and i-ELISA tests showed a significant difference in Se with SAT. However, no significant difference in specificity was detected. The DP was 8.44% in the five tests. In conclusion, LAT using SBPPs of B. melitensis could be a suitable serodiagnostic field test for ovine brucellosis, with high sensitivity and specificity. © The Author(s) 2016.
Screening for colon cancer: A test for occult blood.
Khakimov, N; Khasanova, G; Ershova, K; Gibadullina, L; Vetkina, T; Lobisheva, G; Chumakova, A
2015-01-01
The relevance of the problem of colorectal cancer (CRC) is evident because of extremely high morbidity and mortality rates, associated with this disease. CRC is mostly diagnosed only at very advanced stages. The reduction of mortality can be achieved by the popularization of screening-methods for early identification of CRC and adenomatous polyps of the colon, which are proved to be precancerous condition. Fecal occult blood test is a well-known method of screening for CRC. The advantages of this method when compared, for example, with colonoscopy are its simplicity and cost-effectiveness.Two techniques are usually used for detection of occult blood in the stool: Hemoccult (Guaiac) test and immunochemical test for hemoglobin. There is no consensus among researchers regarding the validity of these tests for the diagnosis of colorectal cancer. For example, J.S. Mandel (1996) notes 60% sensitivity of Guaiac-test for the detection of the early forms of colorectal cancer, while O.I. Kit (2014) suggets that it is not higher than 30%. There are also various opinions about specificity of these two tests. To review the literature on the validity of the fecal occult blood tests for the diagnosis of CRC. We looked for articles (electronic versions) available for free in the full-text versions, published from June 1, 1990 to December 31, 2014 in Russian or English. The following databases were used for search: E-LIBRARY; Cochrane; MEDLINE; EMBASE; Google search. Only original research papers were analyzed. Literature reviews or systematic reviews were not taken for analyses. 1) use of Guaiac and/or immunochemical fecal occult blood test as screening-tests for the detection of colorectal cancer and/or colon polyps (1 cm or more in diameter) in people older than 45 years; 2) comparing of results with the results of colonoscopy (colonoscopy is counted by majority of the authors as a "gold standard" for the diagnosis of CRC and adenomatous polyps). Initial keyword search returned 803 000 results, of which 449 sources were selected. After reading the abstracts, 29 articles that met inclusion criteria were kept. 10 other articles were excluded after that because they did not contain enough data for extraction or did not contain a control group. At the final step 19 articles were used for meta-analysis.Forest plot and Rock curve, which were developed with inclusion of the data from all studies, showed heterogeneity of the data. Additional analyzes were performed in subgroups with different diagnoses and various tests.The sensitivity of the Guaiac test for the diagnosis of colorectal cancer varied from 0.13 to 1.00, and specificity - from 0.69 to 0.99. The sensitivity of the immunochemical test for the diagnosis of CRC ranged from 0.42 to 0.94 with specificity ranging from 0.40 to 1.00.The sensitivity of the Guaiac test for the diagnosis of the colon polyps was between 0.05 and 0.69, and its specificity - from 0.67 to 0.98. The sensitivity of the immunochemical test for the diagnosis of polyps was from 0.24 to 0.75, and its specificity - from 0.40 to 0.97.Bivariate analysis of the validity of Guaiac test and immunochemical method for the diagnosis of colorectal cancer showed better results for the immunochemical test compared to Guaiac test. The tests showed very similar results when used for the diagnosis of polyposis. Bivariate analysis, comparing the validity of tests for the diagnosis of colorectal cancer versus polyposis demonstrated better results for CRC.Multivariate analysis of the validity of the Guaiac and immunochemical tests for the diagnosis of colorectal cancer and polyps also showed better results for detection of colorectal cancer compared with the polyps for both tests. At the same time the highest validity for the diagnosis of CRC was demonstrated for immunochemical analysis. 1. The sensitivity of the Guaiac test for occult blood in stool is lower than its specificity.2. Broad dispersion of the validity characteristics of the fecal occult blood tests was observed.3. The validity of tests for occult blood was higher when they were used for detection of colorectal cancer than of colon polyposis.4. The highest validity rate has been demonstrated for the immunochemical test when it was used for colon cancer screening.
Whelen, A Christian; Bankowski, Matthew J; Furuya, Glenn; Honda, Stacey; Ueki, Robert; Chan, Amelia; Higa, Karen; Kumashiro, Diane; Moore, Nathaniel; Lee, Roland; Koyamatsu, Terrie; Effler, Paul V
2010-01-01
We integrated multicenter, real-time (RTi) reverse transcription polymerase chain reaction (RT-PCR) screening into a statewide laboratory algorithm for influenza surveillance and response. Each of three sites developed its own testing strategy and was challenged with one randomized and blinded panel of 50 specimens previously tested for respiratory viruses. Following testing, each participating laboratory reported its results to the Hawaii State Department of Health, State Laboratories Division for evaluation and possible discrepant analysis. Two of three laboratories reported a 100% sensitivity and specificity, resulting in a 100% positive predictive value and a 100% negative predictive value (NPV) for influenza type A. The third laboratory showed a 71% sensitivity for influenza type A (83% NPV) with 100% specificity. All three laboratories were 100% sensitive and specific for the detection of influenza type B. Discrepant analysis indicated that the lack of sensitivity experienced by the third laboratory may have been due to the analyte-specific reagent probe used by that laboratory. Use of a newer version of the product with a secondary panel of 20 specimens resulted in a sensitivity and specificity of 100%. All three laboratories successfully verified their ability to conduct clinical testing for influenza using diverse nucleic acid extraction and RTi RT-PCR platforms. Successful completion of the verification by all collaborating laboratories paved the way for the integration of those facilities into a statewide laboratory algorithm for influenza surveillance and response.
Optimisation of the zinc sulphate turbidity test for the determination of immune status.
Hogan, I; Doherty, M; Fagan, J; Kennedy, E; Conneely, M; Crowe, B; Lorenz, I
2016-02-13
Failure of passive transfer of maternal immunity occurs in calves that fail to absorb sufficient immunoglobulins from ingested colostrum. The zinc sulphate turbidity test has been developed to test bovine neonates for this failure. The specificity of this test has been shown to be less than ideal. The objective was to examine how parameters of the zinc sulphate turbidity test may be manipulated in order to improve its diagnostic accuracy. One hundred and five blood samples were taken from calves of dairy cows receiving various rates of colostrum feeding. The zinc sulphate turbidity test was carried out multiple times on each sample, varying the solution strength, time of reaction and wavelength of light used and the results compared with those of a radial immunodiffusion test, which is the reference method for measuring immunoglobulin concentration in serum. Reducing the time over which the reaction occurs, or increasing the wavelength of light used to read the turbidity, resulted in decreased specificity without improving sensitivity. Increasing the concentration of the zinc sulphate solution used in the test was shown to improve the specificity without decreasing sensitivity. Examination of the cut-off points suggested that a lower cut-off point would improve the performance. British Veterinary Association.
Diagnostic approach in cases with suspected work-related asthma
2013-01-01
Background Work-related asthma (WRA) is a major cause of respiratory disease in modern societies. The diagnosis and consequently an opportunity for prevention are often missed in practice. Methods Based on recent studies and systematic reviews of the literature methods for detection of WRA and identification of specific causes of allergic WRA are discussed. Results and Conclusions All workers should be asked whether symptoms improve on days away from work or on holidays. Positive answers should lead to further investigation. Spirometry and non-specific bronchial responsiveness should be measured, but carefully performed and validly analysed serial peak expiratory flow or forced expiratory volume in one second (FEV1) measurements are more specific and confirm occupational asthma in about 82% of those still exposed to the causative agent. Skin prick testing or specific immunoglobulin E assays are useful to document allergy to high molecular weight allergens. Specific inhalational challenge tests come closest to a gold standard test, but lack standardisation, availability and sensitivity. Supervised workplace challenges can be used when specific challenges are unavailable or the results non-diagnostic, but methodology lacks standardisation. Finally, if the diagnosis remains unclear a follow-up with serial measurements of FEV1 and non-specific bronchial hyperresponsiveness should detect those likely to develop permanent impairment from their occupational exposures. PMID:23768266
Dynamic testing in schizophrenia: does training change the construct validity of a test?
Wiedl, Karl H; Schöttke, Henning; Green, Michael F; Nuechterlein, Keith H
2004-01-01
Dynamic testing typically involves specific interventions for a test to assess the extent to which test performance can be modified, beyond level of baseline (static) performance. This study used a dynamic version of the Wisconsin Card Sorting Test (WCST) that is based on cognitive remediation techniques within a test-training-test procedure. From results of previous studies with schizophrenia patients, we concluded that the dynamic and static versions of the WCST should have different construct validity. This hypothesis was tested by examining the patterns of correlations with measures of executive functioning, secondary verbal memory, and verbal intelligence. Results demonstrated a specific construct validity of WCST dynamic (i.e., posttest) scores as an index of problem solving (Tower of Hanoi) and secondary verbal memory and learning (Auditory Verbal Learning Test), whereas the impact of general verbal capacity and selective attention (Verbal IQ, Stroop Test) was reduced. It is concluded that the construct validity of the test changes with dynamic administration and that this difference helps to explain why the dynamic version of the WCST predicts functional outcome better than the static version.
Lempp, Jason M; Zajdowicz, Margan J; Hankinson, Arlene L; Toney, Sean R; Keep, Lisa W; Mancuso, James D; Mazurek, Gerald H
2017-01-01
Immunologic tests such as the tuberculin skin test (TST) and QuantiFERON®-TB Gold In-Tube test (QFT-GIT) are designed to detect Mycobacterium tuberculosis infection, both latent M. tuberculosis infection (LTBI) and infection manifesting as active tuberculosis disease (TB). These tests need high specificity to minimize unnecessary treatment and high sensitivity to allow maximum detection and prevention of TB. Estimate QFT-GIT specificity, compare QFT-GIT and TST results, and assess factor associations with test discordance among U.S. Navy recruits. Among 792 subjects with completed TST and QFT-GIT, 42(5.3%) had TST indurations ≥10mm, 23(2.9%) had indurations ≥15mm, 14(1.8%) had positive QFT-GIT results, and 5(0.6%) had indeterminate QFT-GITs. Of 787 subjects with completed TST and determinate QFT-GIT, 510(64.8%) were at low-risk for infection, 277(35.2%) were at increased risk, and none had TB. Among 510 subjects at low-risk (presumed not infected), estimated TST specificity using a 15mm cutoff, 99.0% (95%CI: 98.2-99.9%), and QFT-GIT specificity, 98.8% (95%CI: 97.9-99.8%), were not significantly different (p>0.99). Most discordance was among recruits at increased risk of infection, and most was TST-positive but QFT-GIT-negative discordance. Of 18 recruits with TST ≥15mm but QFT-GIT negative discordance, 14(78%) were at increased risk. TB prevalence in country of birth was the strongest predictor of positive TST results, positive QFT-GIT results, and TST-positive but QFT-GIT-negative discordance. Reactivity to M. avium purified protein derivative (PPD) was associated with positive TST results and with TST-positive but QFT-GIT-negative discordance using a 10 mm cutoff, but not using a 15 mm cutoff or with QFT-GIT results. M. tuberculosis infection prevalence was low, with the vast majority of infection occurring in recruits with recognizable risks. QFT-GIT and TST specificities were high and not significantly different. Negative QFT-GIT results among subjects with TST induration ≥15 mm who were born in countries with high TB prevalence, raise concerns.
Short report: Influence of culture and trauma history on autobiographical memory specificity.
Humphries, Clare; Jobson, Laura
2012-01-01
This study investigated the influence of culture and trauma history on autobiographical memory specificity. Chinese international and British undergraduate university students (N=64) completed the autobiographical memory test, Hopkins symptom checklist-25, twenty statements test, trauma history questionnaire, and impact of events scale-revised. The results indicated that the British group provided significantly more specific memories than the Chinese group. The high trauma exposure group provided significantly fewer specific autobiographical memories than the low trauma exposure group. The interaction was not significant. The findings suggest that even in cultures where specificity is not as evident in autobiographical remembering style, trauma exposure appears to exert similar influence on autobiographical memory specificity.
Capturing specific abilities as a window into human individuality: the example of face recognition.
Wilmer, Jeremy B; Germine, Laura; Chabris, Christopher F; Chatterjee, Garga; Gerbasi, Margaret; Nakayama, Ken
2012-01-01
Proper characterization of each individual's unique pattern of strengths and weaknesses requires good measures of diverse abilities. Here, we advocate combining our growing understanding of neural and cognitive mechanisms with modern psychometric methods in a renewed effort to capture human individuality through a consideration of specific abilities. We articulate five criteria for the isolation and measurement of specific abilities, then apply these criteria to face recognition. We cleanly dissociate face recognition from more general visual and verbal recognition. This dissociation stretches across ability as well as disability, suggesting that specific developmental face recognition deficits are a special case of a broader specificity that spans the entire spectrum of human face recognition performance. Item-by-item results from 1,471 web-tested participants, included as supplementary information, fuel item analyses, validation, norming, and item response theory (IRT) analyses of our three tests: (a) the widely used Cambridge Face Memory Test (CFMT); (b) an Abstract Art Memory Test (AAMT), and (c) a Verbal Paired-Associates Memory Test (VPMT). The availability of this data set provides a solid foundation for interpreting future scores on these tests. We argue that the allied fields of experimental psychology, cognitive neuroscience, and vision science could fuel the discovery of additional specific abilities to add to face recognition, thereby providing new perspectives on human individuality.
Fabre, R; Sobhani, I; Laurent-Puig, P; Hedef, N; Yazigi, N; Vissuzaine, C; Rodde, I; Potet, F; Mignon, M; Etienne, J P
1994-01-01
Ulcer recurrence is probably related to residual Helicobacter pylori (H pylori). Histological examination and culture are considered to be the most specific tests. CLO test is a rapid but less specific test, which is usually used as an alternative test to culture. The aim of this study was to investigate the efficiency of a simplified polymerase chain reaction (PCR) assay as a procedure for the diagnosis of gastric H pylori infection of patients. Biopsy specimens were obtained from antral mucosa of 58 patients at endoscopy and submitted to four tests for detection of H pylori. The bacteria were found in 53%, 43%, 48%, and 50% of patients according to the results of PCR, CLO test, culture, and histological examination. Twenty three patients had both negative histology and negative culture and PCR was negative in all of these. Thirteen patients were not classified because only histology or culture was positive and 10 of these had a positive PCR test. When the diagnosis of H pylori was established by agreement with both histology and culture or three positive tests out of four, 29 patients were H pylori positive (28 having had three positive tests and one displaying positive histology and culture), and 26 were negative, and three undetermined. PCR proved the most sensitive and specific test. These results suggest the simplified PCR assay may be a valuable test for the detection of H pylori. Images p906-a PMID:8063217
NASA Astrophysics Data System (ADS)
Chen, I.-H.; Horikawa, S.; Xi, J.; Wikle, H. C.; Barbaree, J. M.; Chin, B. A.
2017-05-01
Phage based magneto-elastic (ME) biosensors have been shown to be able to rapidly detect Salmonella in various food systems to serve food pathogen monitoring purposes. In this ME biosensor platform, the free-standing strip-shaped magneto-elastic sensor is the transducer and the phage probe that recognizes Salmonella in food serves as the bio-recognition element. According to Sorokulova et al. at 2005, a developed oligonucleotide probe E2 was reported to have high specificity to Salmonella enterica Typhimurium. In the report, the specificity tests were focused in most of Enterobacterace groups outside of Salmonella family. Here, to understand the specificity of phage E2 to different Salmonella enterica serotypes within Salmonella Family, we further tested the specificity of the phage probe to thirty-two Salmonella serotypes that were present in the major foodborne outbreaks during the past ten years (according to Centers for Disease Control and Prevention). The tests were conducted through an Enzyme linked Immunosorbent Assay (ELISA) format. This assay can mimic probe immobilized conditions on the magnetoelastic biosensor platform and also enable to study the binding specificity of oligonucleotide probes toward different Salmonella while avoiding phage/ sensor lot variations. Test results confirmed that this oligonucleotide probe E2 was high specific to Salmonella Typhimurium cells but showed cross reactivity to Salmonella Tennessee and four other serotypes among the thirty-two tested Salmonella serotypes.
Testing of the high accuracy inertial navigation system in the Shuttle Avionics Integration Lab
NASA Technical Reports Server (NTRS)
Strachan, Russell L.; Evans, James M.
1991-01-01
The description, results, and interpretation is presented of comparison testing between the High Accuracy Inertial Navigation System (HAINS) and KT-70 Inertial Measurement Unit (IMU). The objective was to show the HAINS can replace the KT-70 IMU in the space shuttle Orbiter, both singularly and totally. This testing was performed in the Guidance, Navigation, and Control Test Station (GTS) of the Shuttle Avionics Integration Lab (SAIL). A variety of differences between the two instruments are explained. Four, 5 day test sessions were conducted varying the number and slot position of the HAINS and KT-70 IMUs. The various steps in the calibration and alignment procedure are explained. Results and their interpretation are presented. The HAINS displayed a high level of performance accuracy previously unseen with the KT-70 IMU. The most significant improvement of the performance came in the Tuned Inertial/Extended Launch Hold tests. The HAINS exceeded the 4 hr specification requirement. The results obtained from the SAIL tests were generally well beyond the requirements of the procurement specification.
1989-08-01
specific elements identified as useful for selection (Primoff & Eyde , 1988). The JEM approach uses a slightly different scale when test development is not...related to GATB scores and tests developed to measure specific elements (Primoff & Eyde , 1988). Of the ability taxonomies reviewed in this study, the...only formative at this point in time, the results of recent research in cognitive psychology and in use of the computer as a testing medium have not
Analysis of aquifer tests in the Punjab region of West Pakistan
Bennett, Gordon D.; ,; Sheikh, Ijaz Ahmed; Alr, Sabire
1967-01-01
The results of 141 pumping tests in the Punjab Plain of West Pakistan are reported. Methods of test analysis are described in detail, and an outline of the theory underlying these methods is given. The lateral permeability of the screened interval is given for all tests; the specific yield of the material at water-table depth is given for 1(6 tests; and the vertical permeability of the material between the water table and the top of the screen is given for 14 tests. The lateral permeabilities are predominantly in the range 0.001 to 0.006 cfs per sq ft; the average value is 0.0032 cfs per sq ft. Specific yields generally range from 0.02 to 0.26; the average value is 0.14. All vertical permeability results fall in the range 10 -5 to 10 -3 cfs per sq ft.
Trinh, Dai Quang; Ogawa, Haruko; Bui, Vuong Nghia; Nguyen, Tham Thi Hong; Gronsang, Dulyatad; Baatartsogt, Tugsbaatar; Kizito, Mugimba Kahoza; AboElkhair, Mohammed; Yamaguchi, Shigeo; Nguyen, Viet Khong; Imai, Kunitoshi
2015-09-01
A blocking latex agglutination test (b-LAT) developed in this study was evaluated for the detection of antibodies against chicken anemia virus (CAV) in chickens. Polystyrene latex beads were coupled with a neutralizing monoclonal antibody (mAb) to CAV (mAb-beads). When mAb-beads were mixed with antigens prepared from the lysate of MDCC-MSB1 cells infected with CAV, agglutination occurred. A short pre-incubation of CAV antigens with CAV-specific antiserum inhibited the agglutination of mAb-beads. The test results were obtained within 5min. The specificity of b-LAT was evaluated using sera from specific pathogen-free chickens and sera containing antibodies to avian influenza virus, Newcastle disease virus, infectious bursal disease virus, and Marek's disease virus; nonspecific agglutination and cross-reactivity with antibodies to unrelated viruses were not observed. The examination of 94 serum samples collected from commercial breeder chickens of various ages (17-63 weeks) revealed good agreement (93.6%, Kappa value=0.82) between b-LAT and a virus neutralization test, known to be most sensitive and specific in the detection of antibodies to CAV. These results indicate that b-LAT, a simple and rapid test, is a useful and reliable tool in CAV serology. Copyright © 2015 Elsevier B.V. All rights reserved.
Detecting High Hyperopia: The Plus Lens Test and the Spot Vision Screener.
Feldman, Samuel; Peterseim, Mae Millicent W; Trivedi, Rupal H; Edward Wilson, M; Cheeseman, Edward W; Papa, Carrie E
2017-05-01
To evaluate the usefulness of the Plus Lens (Goodlite Company, Elgin, IL) test and the Spot Vision Screener (Welch Allyn, Skaneateles Falls, NY) in detecting high hyperopia in a pediatric population. Between June and August 2015, patients were screened with the Spot Vision Screener and the Plus Lens test prior to a scheduled pediatric ophthalmology visit. The following data were analyzed: demographic data, Plus Lens result, Spot Vision Screener result, cycloplegic refraction, and examination findings. Sensitivity/specificity and positive/negative predictive values were calculated for the Plus Lens test and Spot Vision Screener in detecting hyperopia as determined by the "gold-standard" cycloplegic refraction. A total of 109 children (average age: 82 months) were included. Compared to the ophthalmologist's cycloplegic refraction, the Spot Vision Screener sensitivity for +3.50 diopters (D) hyperopia was 31.25% and the specificity was 100%. The Plus Lens sensitivity for +3.50 D hyperopia was 43.75% and the specificity was 89.25%. Spot Vision Screener sensitivity increased with higher degrees of hyperopia. In this preliminary study, the Plus Lens test and the Spot Vision Screener demonstrated moderate sensitivity with good specificity in detecting high hyperopia. [J Pediatr Ophthalmol Strabismus. 2017;54(3):163-167.]. Copyright 2017, SLACK Incorporated.
Lindbaek, Morten; Høiby, Ernst Arne; Lermark, Gro; Steinsholt, Inger Marie; Hjortdahl, Per
2004-12-01
To compare an antigen detection test (GAS antigen test) with the results from combinations of two various bacteriological test media in general practice patients with sore throat. Furthermore to assess the diagnostic properties of the chosen GAS antigen test and to compare semi-quantitative results of this test with the bacterial load found in the throat culture. Two Norwegian general practices in Stokke and Kongsberg communities. 306 patients with sore throat lasting less than 7 days; 244 were adults, 62 were children under 10 years old, mean age 23.9 years (SD 15.0), 40% were men. Results from GAS antigen test, and distribution of bacteriological findings in throat cultures, compared with the results of our GAS antigen test; semi-quantitative results of the GAS antigen test compared with the bacterial load by culture. In the primary culture 110 patients harboured group A streptococci (GAS) infection, while the second culture identified another 17, giving a total of 127 patients. Some 33 patients harboured large-colony groups C and G. The GAS antigen test used had a sensitivity of 97% and specificity of 95% regarding GAS when compared with the two cultures. We found a significant correlation between the bacterial loads by culture and the semi-quantitative results of the GAS antigen test. By using a second, different set of bacteriological media, we identified an additional 17 patients with GAS infections. This raises the question of validity of frequently used reference standards in studies related to streptococcal infections. Compared with the combined results of the two throat cultures, the GAS antigen test used showed high sensitivity and specificity. Semi-quantitative evaluations of the rapid immunological test may also be of clinical value.
Allergy to dexchlorpheniramine. Study of a case.
Cáceres Calle, O; Fernández-Benítez, M
2004-01-01
Dexchlorpheniramine (DH) is a classical or first generation antihistamine belonging to the ethanolamine group. Adverse effects related to these antihistamines are frequent, but the hypersensitivity reactions described in the literature since 1940 are exceptional. We report the case of a 32-year-old woman who experienced two episodes of akathisia secondary to intravenous (i.v.) dexchlorpheniramine administration for a possible hypersensitivity reaction to local anesthetics. Allergological study consisted of the following tests: skin prick tests with routine allergens, with a negative result; skin prick and intradermal tests with local anesthetics and DH, with a positive result to DH in the intradermal skin test (+ +); serum specific IgE, which was within normal levels; histamine release test with DH with a negative result, and the basophil activation test (BAT) with local anesthetics and DH, which was positive for DH and weakly positive to Lidocaine. BAT is proving to be a highly useful tool in the field of drug allergy, with a higher sensitivity and specificity than other in vitro tests. Because it avoids the need for provocation tests, this is especially important in drug-induced allergic reactions in which in vivo tests are repeatedly negative despite a clear clinical history.
Experimental evidence supports a sex-specific selective sieve in mitochondrial genome evolution.
Innocenti, Paolo; Morrow, Edward H; Dowling, Damian K
2011-05-13
Mitochondria are maternally transmitted; hence, their genome can only make a direct and adaptive response to selection through females, whereas males represent an evolutionary dead end. In theory, this creates a sex-specific selective sieve, enabling deleterious mutations to accumulate in mitochondrial genomes if they exert male-specific effects. We tested this hypothesis, expressing five mitochondrial variants alongside a standard nuclear genome in Drosophila melanogaster, and found striking sexual asymmetry in patterns of nuclear gene expression. Mitochondrial polymorphism had few effects on nuclear gene expression in females but major effects in males, modifying nearly 10% of transcripts. These were mostly male-biased in expression, with enrichment hotspots in the testes and accessory glands. Our results suggest an evolutionary mechanism that results in mitochondrial genomes harboring male-specific mutation loads.
42 CFR 37.95 - Specifications for performing spirometry examinations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... examinations must include the following: (1) Pre-test checklist. A short Spirometry Pre-Test Checklist (Form... spirometry examinations electronically with content as specified in § 37.96(b), pre-test screening checklists... spirometry examinations, pre-test checklists, and standardized respiratory assessment results in electronic...
Radiation Testing on State-of-the-Art CMOS: Challenges, Plans, and Preliminary Results
NASA Technical Reports Server (NTRS)
LaBel, Kenneth A.; Cohn, Lewis M.
2009-01-01
At GOMAC 2007 and 2008, we discussed a variety of challenges for radiation testing of modern semiconductor devices and technologies [1, 2]. In this presentation, we provide more specific details in this on-going investigation focusing on out-of-the-box lessons observed for providing radiation effects assurances as well as preliminary test results.
Kunkle, Gerald A.
2018-01-31
Two identical Radar Stage Sensors from Forest Technology Systems were evaluated to determine if they are suitable for U.S. Geological Survey (USGS) hydrologic data collection. The sensors were evaluated in laboratory conditions to evaluate the distance accuracy of the sensor over the manufacturer’s specified operating temperatures and distance to water ranges. Laboratory results were compared to the manufacturer’s accuracy specification of ±0.007 foot (ft) and the USGS Office of Surface Water (OSW) policy requirement that water-level sensors have a measurement uncertainty of no more than 0.01 ft or 0.20 percent of the indicated reading. Both of the sensors tested were within the OSW policy requirement in both laboratory tests and within the manufacturer’s specification in the distance to water test over tested distances from 3 to 15 ft. In the temperature chamber test, both sensors were within the manufacturer’s specification for more than 90 percent of the data points collected over a temperature range of –40 to +60 degrees Celsius at a fixed distance of 8 ft. One sensor was subjected to an SDI-12 communication test, which it passed. A field test was conducted on one sensor at a USGS field site near Landon, Mississippi, from February 5 to March 29, 2016. Water-level measurements made by the radar during the field test were in agreement with those made by the Sutron Accubar Constant Flow Bubble Gauge.Upon the manufacturer’s release of updated firmware version 1.09, additional SDI-12 and temperature testing was performed to evaluate added SDI-12 functions and verify that performance was unaffected by the update. At this time, an Axiom data logger is required to perform a firmware update on this sensor. The data confirmed the results of the original test. Based on the test results, the Radar Stage Sensor is a suitable choice for USGS hydrologic data collection.
NASA Astrophysics Data System (ADS)
Ilias, Mohammad
Pavement preservation is a rapidly growing strategy for prolonging pavement service life. Pavement preservation consists of applying a thin layer of asphalt binder or emulsion with or without aggregate to the surface of an existing pavement. Preservation treatments do not provide any structural strength to the pavement but restores skid resistance, seals existing cracks, protects the underlying pavement from intrusion of water, and reduces further oxidative aging of the underlying pavement. In recent years, significant research has been dedicated to improving design of pavement preservation treatments. In pavement preservation treatments, asphalt emulsion is the predominant binding material used because of its low viscosity compared to asphalt cement which allows for production at greatly reduced temperatures, leading to energy efficiency, and potential cost savings. Currently, specifications for emulsions used in pavement preservation treatments are empirical and lack of direct relationship to performance. This study seeks to improve specifications for emulsions used in preservation treatments by developing performancerelated specifications (PRS) for (a) fresh emulsion properties, (b) microsurfacing emulsion residue, and (c) low-temperature raveling of chip seal emulsion residues. Fresh emulsion properties dictate constructability and stability, and consequently the resultant performance of a preservation treatment once placed. Specification test methods are proposed for chip seals, microsurfacings, and spray seals that reflect storage and construction conditions of the emulsions. Performance is quantified using viscosity measurements. Specification limits are determined based on a prior knowledge of emulsion performance coupled with statistical analyses. Microsurfacings are a preservation treatment consisting of application of a thin layer of asphalt emulsion -- fine aggregate mixture. Presently, mixture design and performances of microsurfacing mixtures are appraised using the procedure specified by the International Slurry Surfacing Association (ISSA) with no provision for quantifying microsurfacing residue performance. In this study, residue performance is quantified using the Multiple Stress Creep and Recovery (MSCR) test for rutting and bleeding, the Bitumen Bond Strength Test (BBS) for raveling, Low Temperature Frequency (LTF) test for low temperature Bending Beam Rheometer (BBR) properties prediction, and Single Edge Notched Bend (SENB) fracture test developed under this work. Microsurfacing mixture performance is quantified using the Wet Track Abrasion Test (WTAT) for raveling, Model Mobile Load Simulator (MMLS3) for rutting and bleeding, and SENB test developed for low-temperature cracking. Microsurfacing mixture performance is correlated to residue properties in order to identify critical emulsion residue properties in determining performance and to derive specification limits. Results indicate rutting and thermal cracking are the distresses most directly related to the emulsion residue performance. Correspondingly, specifications are proposed to address rutting at high temperature and thermal cracking at low temperature based on the relationship between residue and mixture results coupled. In addition, test methods and specification criteria are developed to address lowtemperature raveling resistance of emulsion residues used in chip seals. The SENB test is used to quantify residue resistance to thermal cracking under the assumption that lowtemperature raveling occurs primarily by cohesive fracture of the residue in the chip seal. The Vialit test is modified and employed for quantifying raveling resistance of chip seals mixture for determining if the SENB test captures binder contribution to mixture raveling. The correlation between residue and mixture properties have been used to assess applicability of the residue tests and to derive specification limits.
Badawy, Abdulla A.-B.; Dougherty, Donald M.; Richard, Dawn M.
2010-01-01
The acute tryptophan or tyrosine plus phenylalanine depletion and loading tests are powerful tools for studying the roles of serotonin, dopamine and noradrenaline in normal subjects and those with behavioural disorders. The current amino acid formulations for these tests, however, are associated with undesirable decreases in ratios of tryptophan or tyrosine plus phenylalanine to competing amino acids resulting in loss of specificity. This could confound biochemical and behavioural findings. Compositions of current formulations are reviewed, the biochemical principles underpinning the tests are revisited and examples of unintended changes in the above ratios and their impact on monoamine function and behaviour will be demonstrated from data in the literature. The presence of excessive amounts of the 3 branched-chain amino acids Leu, Ile and Val is responsible for these unintended decreases and the consequent loss of specificity. Strategies for enhancing the specificity of the different formulations are proposed. PMID:20676231
Badawy, Abdulla A-B; Dougherty, Donald M; Richard, Dawn M
2010-01-01
The acute tryptophan or tyrosine plus phenylalanine depletion and loading tests are powerful tools for studying the roles of serotonin, dopamine and noradrenaline in normal subjects and those with behavioural disorders. The current amino acid formulations for these tests, however, are associated with undesirable decreases in ratios of tryptophan or tyrosine plus phenylalanine to competing amino acids resulting in loss of specificity. This could confound biochemical and behavioural findings. Compositions of current formulations are reviewed, the biochemical principles underpinning the tests are revisited and examples of unintended changes in the above ratios and their impact on monoamine function and behaviour will be demonstrated from data in the literature. The presence of excessive amounts of the 3 branched-chain amino acids Leu, Ile and Val is responsible for these unintended decreases and the consequent loss of specificity. Strategies for enhancing the specificity of the different formulations are proposed.
Construction quality assurance report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roscha, V.
1994-09-08
This report provides a summary of the construction quality assurance (CQA) observation and test results, including: The results of the geosynthetic and soil materials conformance testing. The observation and testing results associates with the installation of the soil liners. The observation and testing results associated with the installation of the HDPE geomembrane liner systems. The observation and testing results associated with the installation of the leachate collection and removal systems. The observation and testing results associated with the installation of the working surfaces. The observation and testing results associated with in-plant manufacturing process. Summary of submittal reviews by Golder Constructionmore » Services, Inc. The submittal and certification of the piping material specifications. The observation and verification associated of the Acceptance Test Procedure results of the operational equipment functions. Summary of the ECNs which are incorporated into the project.« less
Experiments with Test Case Generation and Runtime Analysis
NASA Technical Reports Server (NTRS)
Artho, Cyrille; Drusinsky, Doron; Goldberg, Allen; Havelund, Klaus; Lowry, Mike; Pasareanu, Corina; Rosu, Grigore; Visser, Willem; Koga, Dennis (Technical Monitor)
2003-01-01
Software testing is typically an ad hoc process where human testers manually write many test inputs and expected test results, perhaps automating their execution in a regression suite. This process is cumbersome and costly. This paper reports preliminary results on an approach to further automate this process. The approach consists of combining automated test case generation based on systematically exploring the program's input domain, with runtime analysis, where execution traces are monitored and verified against temporal logic specifications, or analyzed using advanced algorithms for detecting concurrency errors such as data races and deadlocks. The approach suggests to generate specifications dynamically per input instance rather than statically once-and-for-all. The paper describes experiments with variants of this approach in the context of two examples, a planetary rover controller and a space craft fault protection system.
Eller, Leigh A; Eller, Michael A; Ouma, Benson J; Kataaha, Peter; Bagaya, Bernard S; Olemukan, Robert L; Erima, Simon; Kawala, Lilian; de Souza, Mark S; Kibuuka, Hannah; Wabwire-Mangen, Fred; Peel, Sheila A; O'Connell, Robert J; Robb, Merlin L; Michael, Nelson L
2007-10-01
The use of rapid tests for human immunodeficiency virus (HIV) has become standard in HIV testing algorithms employed in resource-limited settings. We report an extensive HIV rapid test validation study conducted among Ugandan blood bank donors at low risk for HIV infection. The operational characteristics of four readily available commercial HIV rapid test kits were first determined with 940 donor samples and were used to select a serial testing algorithm. Uni-Gold Recombigen HIV was used as the screening test, followed by HIV-1/2 STAT-PAK for reactive samples. OraQuick HIV-1 testing was performed if the first two test results were discordant. This algorithm was then tested with 5,252 blood donor samples, and the results were compared to those of enzyme immunoassays (EIAs) and Western blotting. The unadjusted algorithm sensitivity and specificity were 98.6 and 99.9%, respectively. The adjusted sensitivity and specificity were 100 and 99.96%, respectively. This HIV testing algorithm is a suitable alternative to EIAs and Western blotting for Ugandan blood donors.
PHYSICAL EXAMINATIONS FOR DIAGNOSING MENISCAL INJURIES: CORRELATION WITH SURGICAL FINDINGS
Gobbo, Ricardo da Rocha; Rangel, Victor de Oliveira; Karam, Francisco Consoli; Pires, Luiz Antônio Simões
2015-01-01
Objective: A set of five maneuvers for meniscal injuries (McMurray, Apley, Childress and Steinmann 1 and 2) was evaluated and their sensitivity, specificity, accuracy and likelihood were calculated. The same methods were applied to each test individually. Methods: One hundred and fifty-two patients of both sexes who were going to undergo videoarthroscopy on the knee were examined blindly by one of five residents at this hospital, without knowledge of the clinical data and why the patient was going to undergo an operation. This examination was conducted immediately before the videoarthroscopy and its results were recorded in an electronic spreadsheet. The set of maneuvers was considered positive when one was positive. In the individual analysis, it was enough for the test to be positive. Results: The analysis showed that the set of five meniscal tests presented sensitivity of 89%, specificity of 42%, accuracy of 75%, positive likelihood of 1.53 and negative likelihood of 0.26. Individually, the tests presented accuracy of between 48% and 53%. Conclusion: The set of maneuvers for meniscal injuries presented a good accuracy and significant value, especially for ruling out injury. Individually, the tests had less diagnostic value, although the Apley test had better specificity. PMID:27047833
Types of Sensory Integrative Dysfunction among Disabled Learners
ERIC Educational Resources Information Center
Ayres, A. Jean
1972-01-01
R-technique factor analysis was used to correlate results of sensorimotor, psycholinguistic and cognitive tests given to California children with learning disabilities. Results show not all children with specific neural disorders perform poorly on related tests where low scores would be expected. (PD)
Genetic testing in domestic cats
Lyons, Leslie A.
2012-01-01
Varieties of genetic tests are currently available for the domestic cat that support veterinary health care, breed management, species identification, and forensic investigations. Approximately thirty-five genes contain over fifty mutations that cause feline health problems or alterations in the cat’s appearance. Specific genes, such as sweet and drug receptors, have been knocked-out of Felidae during evolution and can be used along with mtDNA markers for species identification. Both STR and SNP panels differentiate cat race, breed, and individual identity, as well as gender-specific markers to determine sex of an individual. Cat genetic tests are common offerings for commercial laboratories, allowing both the veterinary clinician and the private owner to obtain DNA test results. This article will review the genetic tests for the domestic cat, and their various applications in different fields of science. Highlighted are genetic tests specific to the individual cat, which are a part of the cat’s genome. PMID:22546621
Apinyawasisuk, Supanut; Zhou, Xinkai; Tian, Jack J; Garcia, Giancarlo A; Karanjia, Rustum; Sadun, Alfredo A
2017-09-01
Forced eyelid closure test (FECT) is a clinical screening test developed from the original Cogan lid twitch (CLT) sign to assist in the diagnosis of ocular myasthenia gravis (OMG), We evaluated the sensitivity and specificity of FECT compared with CLT and benchmarked to standard diagnostic tests. This study was a retrospective chart review of 48 patients using electronic medical records of those that presented with ptosis and/or diplopia at Doheny Eye Institute, University of California, Los Angeles between February 2015 and April 2016. Patients without FECT testing were excluded. FECT and CLT results, and final diagnosis were recorded. To perform FECT, the patient was asked to squeeze his or her eyelids shut for 5-10 seconds then open quickly and fixate in primary position. The excessive upward overshoot of eyelids movement indicated a positive FECT. The test was performed by a neuro-ophthalmologist before establishing the diagnosis. Patients who had equivocal test results and/or inconclusive final diagnosis were excluded. Of the 48 patients studied, 18 patients (37.5%) had positive FECT; 15 of whom had a final diagnosis of OMG (83.3%). Of the 30 patients with negative FECT, 1 had OMG (3.3%). Of the 48 patients, 35 patients also had a documented CLT result (72.9%). CLT was positive in 11 of these 35 patients (31.4%), and 9 of these 11 had OMG (81.8%). Of the 24 patients with negative CLT, 2 of them had OMG (8.3%). Sensitivity and specificity of FECT were 94% and 91% (joint 95% confidence region: sensitivity × specificity = [0.70, 1] × [0.75, 1]). The relative true-positive fraction (rTPF) between FECT and CLT was 1.15; the relative false-positive fraction was 1.31. FECT is a simple clinical screening test with good sensitivity and specificity for OMG.
[Comparative diagnostic value of Helicobacter pylori infection testing methods].
Girdalidze, A M; Elisabedashvili, G V; Sharvadze, L G; Dzhorbenadze, T A
2013-12-01
In 213 patients with gastric and duodenal pathology, including received surgery, comparative estimation of results of Helicobacter pylori (Hp) infection testing with invasive and noninvasive methods, were performed. Material for invasive endoscopic biopsy test (EBT), including rapid urease test (RUT) for rapid Hp identification by determination of urease activity, smear cytology and histology was extracted on endoscopy or intraoperationally. RUT was carried out with the help of URE-HP test kit. Serological test for Hp antibodies IgG and IgA class was performed by IFA using kit ELISA. 13С urea breath test (UBT) was made by determination of 13/12CO2 in breath samples on infrared spectroscope. Based on 5 different methods of Hp infection testing Hp positivity in 172 (80,8%) and Hp negativity in 41 (19,2%) from 213 examined patients was revealed. 13С-UBT revealed the highest diagnostic value (accuracy-97,5%, sensibility-97,0%, specificity-100%) in Hp infection diagnostics. In treatment efficiency control this parameters of 13С-UBT are also much high (96,7%, 90,0% and 100% respectively). In spite of high sensitivity of serological test (100%), it had comparative low specificity (71,0%) with high probability of false positive results in treated patients (antibodies titer to Hp after eradication retains for a long time). Thought, this test may be successfully used only in primary patients and in epidemiological studies. Among three methods of EBT, Hp infection detection with RUT revealed the best results (accuracy-94,8%, sensibility-95,0%, specificity-100%). Correlation of RUT and UBT results and much higher diagnostic value of UBT, necessitate RUT with histological study of stomach body mucosa to perform in patients over 45 year, with prolonged anamnesis and dangerous symptoms of disease. In Hp positive patients correlation of index DOB‰ of breath test with results of RUT was revealed. This can serve the index DOB‰ of 13С-UBT as a marker of Hp infection rate. The (accuracy, sensibility and specificity of breath test with local made 13С-urea (98,7%, 98,5% and 100% respectively) are the same as those for BT with standard 13С-urea (96,7%, 96,2% and 100% respectively). Above mentioned, 13С-UBT advantages (noninvasiveness, simplicity, rapidity, safety) and high diagnostic value exceeding same of other applied tests, give us opportunity to offer 13С-UBT as screening method of Hp infection diagnosis and a method of choise in control of Hp infection treatment efficiency.
[User's requests (from a practitioner's perspective)].
Ohnishi, T
1997-08-01
As a practitioner, I have to rely on outside clinical laboratories and affiliated hospitals to perform laboratory tests. In this abstract, I describe specific problems I have encountered with third-party laboratories, and propose solutions for these problems to optimize use of laboratory tests. BLOOD TESTS: The most frequent problem in ordering blood tests is the lack of detailed information regarding sampling conditions. I often have to call laboratories to check whether the sample should be serum or plasma, what volume is needed, whether the sample should be cooled, etc. I propose that clinical laboratories should provide practitioners' manuals that describe specific sampling information. Most laboratories do not keep the data from ultrasonographic tests. The lack of these is most problematic when test results are interpreted differently by laboratories and by practitioners. Retaining the data would also help private laboratories improve the quality of the test by enabling them to compare their interpretations with others'. ANNUAL MEDICAL SCREENING: Even if an abnormal finding is detected at medical screening clinics, the final diagnosis is usually not sent back to the screening facilities. This is highly recommended to establish an official system that mediates the feedback to screening centers. MRI: Due to miscommunication between practitioners and radiologists, the test is sometimes performed inappropriately. A thorough consultation should occur before the test to clarify specific goals for each patient. PATHOLOGICAL TESTS: Interpretation of results is often inconsistent among laboratories. Independent clinical laboratories tend to report results without indicating sample problems, while pathology departments at affiliated hospitals tend to emphasize sample problems instead of diagnosis or suggesting ways to improve sample quality. Mutual communication among laboratories would help standardize the quality of pathological tests.
Purrucker, Jan C; Haas, Kirsten; Rizos, Timolaos; Khan, Shujah; Poli, Sven; Kraft, Peter; Kleinschnitz, Christoph; Dziewas, Rainer; Binder, Andreas; Palm, Frederick; Jander, Sebastian; Soda, Hassan; Heuschmann, Peter U; Veltkamp, Roland
2017-01-01
In patients who present with acute ischemic stroke while on treatment with non-vitamin K antagonist oral anticoagulants (NOACs), coagulation testing is necessary to confirm the eligibility for thrombolytic therapy. We evaluated the current use of coagulation testing in routine clinical practice in patients who were on NOAC treatment at the time of acute ischemic stroke. Prospective multicenter observational RASUNOA registry (Registry of Acute Stroke Under New Oral Anticoagulants; February 2012-2015). Results of locally performed nonspecific (international normalized ratio, activated partial thromboplastin time, and thrombin time) and specific (antifactor Xa tests, hemoclot assay) coagulation tests were documented. The implications of test results for thrombolysis decision-making were explored. In the 290 patients enrolled, nonspecific coagulation tests were performed in ≥95% and specific coagulation tests in 26.9% of patients. Normal values of activated partial thromboplastin time and international normalized ratio did not reliably rule out peak drug levels at the time of the diagnostic tests (false-negative rates 11%-44% [95% confidence interval 1%-69%]). Twelve percent of patients apparently failed to take the prescribed NOAC prior to the acute event. Only 5.7% (9/159) of patients in the 4.5-hour time window received thrombolysis, and NOAC treatment was documented as main reason for not administering thrombolysis in 52.7% (79/150) of patients. NOAC treatment currently poses a significant barrier to thrombolysis in ischemic stroke. Because nonspecific coagulation test results within normal range have a high false-negative rate for detection of relevant drug concentrations, rapid drug-specific tests for thrombolysis decision-making should be established. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01850797. © 2016 American Heart Association, Inc.
Value of physical tests in diagnosing cervical radiculopathy: a systematic review.
Thoomes, Erik J; van Geest, Sarita; van der Windt, Danielle A; Falla, Deborah; Verhagen, Arianne P; Koes, Bart W; Thoomes-de Graaf, Marloes; Kuijper, Barbara; Scholten-Peeters, Wendy G M; Vleggeert-Lankamp, Carmen L
2018-01-01
In clinical practice, the diagnosis of cervical radiculopathy is based on information from the patient's history, physical examination, and diagnostic imaging. Various physical tests may be performed, but their diagnostic accuracy is unknown. This study aimed to summarize and update the evidence on diagnostic performance of tests carried out during a physical examination for the diagnosis of cervical radiculopathy. A review of the accuracy of diagnostic tests was carried out. The study sample comprised diagnostic studies comparing results of tests performed during a physical examination in diagnosing cervical radiculopathy with a reference standard of imaging or surgical findings. Sensitivity, specificity, likelihood ratios are presented, together with pooled results for sensitivity and specificity. A literature search up to March 2016 was performed in CENTRAL, PubMed (MEDLINE), Embase, CINAHL, Web of Science, and Google Scholar. The methodological quality of studies was assessed using the QUADAS-2. Five diagnostic accuracy studies were identified. Only Spurling's test was evaluated in more than one study, showing high specificity ranging from 0.89 to 1.00 (95% confidence interval [CI]: 0.59-1.00); sensitivity varied from 0.38 to 0.97 (95% CI: 0.21-0.99). No studies were found that assessed the diagnostic accuracy of widely used neurological tests such as key muscle strength, tendon reflexes, and sensory impairments. There is limited evidence for accuracy of physical examination tests for the diagnosis of cervical radiculopathy. When consistent with patient history, clinicians may use a combination of Spurling's, axial traction, and an Arm Squeeze test to increase the likelihood of a cervical radiculopathy, whereas a combined results of four negative neurodynamics tests and an Arm Squeeze test could be used to rule out the disorder. Copyright © 2017 Elsevier Inc. All rights reserved.
O'Driscoll, B R; Powell, G; Chew, F; Niven, R M; Miles, J F; Vyas, A; Denning, D W
2009-11-01
It has been shown that patients with allergic bronchopulmonary aspergillosis (ABPA) and patients with severe asthma with fungal sensitization (SAFS) can benefit from antifungal therapy. It is not known whether allergy skin prick tests (SPT) or specific IgE tests are more sensitive in the identification of patients who are sensitized to fungi and who are therefore candidates for antifungal therapy. To compare SPT and specific serum IgE tests for fungal sensitization in patients with severe asthma. We have undertaken SPT and specific serum IgE tests to six fungi (Aspergillus fumigatus, Candida albicans, Penicillium notatum, Cladosporium herbarum, Alternaria alternata and Botrytis cineria) and specific serum IgE test for Trichophyton in 121 patients with severe asthma (British Thoracic Society/SIGN steps 4 and 5). Sixty-six percent of patients were sensitized to one or more fungi based on SPT and/or specific serum IgE results. Positivity to SPT and/or specific serum IgE was as follows: A. fumigatus 45%, C. albicans 36%, P. notatum 29%, C. herbarum 24%, A. alternata 22%, B. cineria 18%, Trichophyton 17% (specific serum IgE only). Concordance between the tests was 77% overall but only 14-56% for individual fungi. Twenty-nine (24%) patients were sensitized to a single fungus and seven (6%) were sensitized to all seven fungal species. Fifty percent of patients were sensitized to fungal and non-fungal extracts, 21% were sensitized only to non-fungal extracts, 16% were sensitized only to fungal extracts and 13% had no positive tests. This study is consistent with previous reports that fungal sensitization is common in patients with severe asthma. At present, it remains necessary to undertake both SPT and specific serum IgE testing to identify all cases of fungal sensitization. This may be important in the identification of patients with ABPA and SAFS who may benefit from antifungal therapy.
2017-07-07
RESEARCH ARTICLE Self-reported HIV-positive status but subsequent HIV-negative test result using rapid diagnostic testing algorithms among seven sub...America * judith.harbertson.ctr@mail.mil Abstract HIV rapid diagnostic tests (RDTs) combined in an algorithm are the current standard for HIV diagnosis...in many sub-Saharan African countries, and extensive laboratory testing has con- firmed HIV RDTs have excellent sensitivity and specificity. However
46 CFR 164.007-7 - Analysis of results.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 6 2013-10-01 2013-10-01 false Analysis of results. 164.007-7 Section 164.007-7...: SPECIFICATIONS AND APPROVAL MATERIALS Structural Insulations § 164.007-7 Analysis of results. (a) When only one sample is tested, the results of the test shall be binding and no analysis by the Coast Guard will be...
46 CFR 164.007-7 - Analysis of results.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 6 2010-10-01 2010-10-01 false Analysis of results. 164.007-7 Section 164.007-7...: SPECIFICATIONS AND APPROVAL MATERIALS Structural Insulations § 164.007-7 Analysis of results. (a) When only one sample is tested, the results of the test shall be binding and no analysis by the Coast Guard will be...
46 CFR 164.007-7 - Analysis of results.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 6 2011-10-01 2011-10-01 false Analysis of results. 164.007-7 Section 164.007-7...: SPECIFICATIONS AND APPROVAL MATERIALS Structural Insulations § 164.007-7 Analysis of results. (a) When only one sample is tested, the results of the test shall be binding and no analysis by the Coast Guard will be...
46 CFR 164.007-7 - Analysis of results.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 6 2012-10-01 2012-10-01 false Analysis of results. 164.007-7 Section 164.007-7...: SPECIFICATIONS AND APPROVAL MATERIALS Structural Insulations § 164.007-7 Analysis of results. (a) When only one sample is tested, the results of the test shall be binding and no analysis by the Coast Guard will be...
46 CFR 164.007-7 - Analysis of results.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 6 2014-10-01 2014-10-01 false Analysis of results. 164.007-7 Section 164.007-7...: SPECIFICATIONS AND APPROVAL MATERIALS Structural Insulations § 164.007-7 Analysis of results. (a) When only one sample is tested, the results of the test shall be binding and no analysis by the Coast Guard will be...
Prevailing Torque Locking Feature in Threaded Fasteners Using Anaerobic Adhesive
NASA Technical Reports Server (NTRS)
Hernandez, Alan; Hess, Daniel P.
2016-01-01
This paper presents results from tests to assess the use of anaerobic adhesive for providing a prevailing torque locking feature in threaded fasteners. Test procedures are developed and tests are performed on three fastener materials, four anaerobic adhesives, and both unseated assembly conditions. Five to ten samples are tested for each combination. Tests for initial use, reuse without additional adhesive, and reuse with additional adhesive are performed for all samples. A 48-hour cure time was used for all initial use and reuse tests. Test data are presented as removal torque versus removal angle with the specification required prevailing torque range added for performance assessment. Percent specification pass rates for the all combinations of fastener material, adhesive, and assembly condition are tabulated and reveal use of anaerobic adhesive as a prevailing torque locking feature is viable. Although not every possible fastener material and anaerobic adhesive combination provides prevailing torque values within specification, any combination can be assessed using the test procedures presented. Reuse without additional anaerobic adhesive generally provides some prevailing torque, and in some cases within specification. Reuse with additional adhesive often provides comparable removal torque data as in initial use.
Learning needs in clinical biochemistry for doctors in foundation years.
Khromova, Victoria; Gray, Trevor A
2008-01-01
Most medical school curricula have reduced the amount of time available for teaching in pathology despite the fact that junior staff in the early stages of their training were responsible for requesting the majority of pathology tests on acutely ill hospital patients. So, the lack of specific training in this area means that test requesting may be poorly performed and the results ill understood by these staff. This paper describes a questionnaire, which was designed to assist laboratory staff providing targeted teaching in this area. Doctors in Foundation year 1 (F1) and Foundation year 2 (F2) in Sheffield teaching hospitals were given a questionnaire to ascertain how confident they were in requesting and interpreting the results of clinical biochemistry tests. The doctors were also asked about which areas of laboratory medicine they would like to be taught. Responses were received from 82 doctors, about half those in F1 and F2. The survey revealed areas where juniors are less confident in requesting tests and interpreting results. Despite lack of confidence in interpreting the result, 18% were confident about requesting tests. Doctors were also unsure of the effects of common problems like haemolysis on the interpretation of results. More than 70% of the doctors requested specific teaching in these areas. Foundation doctors have learning needs in clinical biochemistry, addressing which would assist them in patient care. While better training in medical school may help in future, there are specific needs for those on the wards now that require targeted teaching.
Evaluation of hyperketonemia risk period and screening protocols for early-lactation dairy cows.
Mahrt, A; Burfeind, O; Heuwieser, W
2015-05-01
The objectives of this study were to describe the onset of hyperketonemia, the number of positive hyperketonemia test results, and the duration of the longest hyperketonemic period during the first 42 d in milk (DIM) in dairy cows. Furthermore, we set out to evaluate test characteristics of single and repeated measurements of β-hydroxybutyric acid (BHBA) during this period to diagnose hyperketonemia. Using an electronic handheld meter, 252 cows from 3 farms were tested twice weekly for hyperketonemia (blood BHBA ≥1.2 mmol/L) during the first 42 DIM, resulting in 12 test results per cow (i.e., in lactation wk 0.5 to 6). Prevalence and incidence of hyperketonemia were calculated for the 12 examination days and the 42-d period, respectively. Test characteristics for the diagnosis of hyperketonemia were calculated for 4 different testing scenarios (testing all cows 1, 2, 3, or 6 times during the first 42 DIM) and 2 different gold-standard definitions (BHBA ≥1.2 mmol/L at least once during the observation period or BHBA ≥1.2 mmol/L at least twice during the observation period). Mean prevalence of hyperketonemia was 11.8%, ranging from 9.6% in lactation wk 0.5 and 2.0 to 14.6% in lactation wk 5.5. In total, 134 cows (53.2%) had at least 1 positive hyperketonemia test result during the whole 42-d period. Of these cows, 46.3% had only 1 positive result. The median first positive hyperketonemia test result was in lactation wk 2.0 [interquartile range (IQR) 1.0-3.5]. Median frequency of positive test results in cows affected by hyperketonemia was 2 positive test results (IQR 1-3). Median duration of the longest hyperketonemic period per cow affected was 1 examination interval (3-4 d; IQR 1-2). Considering a minimum of 1 positive hyperketonemia test result during the first 42 DIM as the gold standard, sensitivity of a single BHBA measurement during this period to diagnose hyperketonemia was 21%. A weekly testing protocol had a sensitivity of 72%. Specificity was 100% in both cases. Considering a minimum of 2 positive hyperketonemia test results as the gold standard, sensitivity and specificity of a single BHBA measurement during the first 42 DIM were 33 and 97%, respectively. A weekly testing protocol provided sensitivity and specificity of 91 and 83%, respectively. We conclude that the risk period for hyperketonemia lasts at least until lactation wk 6, which should be considered when planning hyperketonemia screening programs. Test characteristics of screening protocols depend on testing frequency. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Mallett, Susan; Halligan, Steve; Collins, Gary S.; Altman, Doug G.
2014-01-01
Background Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. Methods In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Results Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. Conclusions The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests. PMID:25353643
Winn-Deen
1998-12-01
Background: Currently analysis of point mutations can be done by allele-specific polymerase chain reaction (PCR) followed by gel analysis or by gene-specific PCR followed by hybridization with an allele-specific probe. Both of these mutation detection methods require post-PCR laboratory time and run the risk of contaminating subsequent experiments with the PCR product liberated during the detection step. The author has combined the PCR amplification and detection steps into a single procedure suitable for closed-tube analysis. Methods and Results: Allele-specific PCR primers were designed as Sunrise energy-transfer primers and contained a 3' terminal mismatch to distinguish between normal and mutant DNA. Cloned normal (W64) and mutant (R64) templates of the beta3-adrenergic receptor gene were tested to verify amplification specificity and yield. A no-target negative control was also run with each reaction. After PCR, each reaction was tested for fluorescence yield by measuring fluorescence on a spectrofluorimeter or fluorescent microtitreplate reader. The cloned controls and 24 patient samples were tested for the W64R mutation by two methods. The direct fluorescence results with the Sunrise allele-specific PCR method gave comparable genotypes to those obtained with the PCR/ restriction digest/gel electrophoresis control method. No PCR artifacts were observed in the negative controls or in the PCR reactions run with the mismatched target. Conclusions: The results of this pilot study indicate good PCR product and fluorescence yield from allele-specific energy-transfer labeled primers, and the capability of distinguishing between normal and mutant alleles based on fluorescence alone, without the need for restriction digestion, gel electrophoresis, or hybridization with an allele-specific probe.
METHOD AND APPARATUS FOR TESTING THE PRESENCE OF SPECIFIC ATOMIC ELEMENTS IN A SUBSTANCE
Putman, J.L.
1960-01-26
Detection of specific atomic elements in a substance and particularly the applicability to well logging are discussed. The principal novelty resides in the determination of several of the auxiliary energy peaks in addition to the main energy peak of the gamma-ray energy spectrum of a substance and comparison of such peaks to the spectrum of the specific atomic element being tested for. thus resulting in identification of same. The invention facilitates the identification of specific elements even when in the presence of other elements having similar gamma energy spectra as to the main energy peaks.
Gungor, Anil; Houser, Steven M; Aquino, Benjamin F; Akbar, Imran; Moinuddin, Rizwan; Mamikoglu, Bulent; Corey, Jacquelynne P
2004-01-01
Among the many methods of allergy diagnosis are intradermal testing (IDT) and skin-prick testing (SPT). The usefulness of IDT has been called into question by some authors, while others believe that studies demonstrating that SPT was superior might have been subject to bias. We conducted a study to compare the validity of SPT and IDT--specifically, the skin endpoint titration (SET) type of IDT--in diagnosing allergic rhinitis. We performed nasal provocation testing on 62 patients to establish an unbiased screening criterion for study entry. Acoustic rhinometric measurements of the nasal responses revealed that 34 patients tested positive and 28 negative. All patients were subsequently tested by SET and SPT. We found that SPT was more sensitive (85.3 vs 79.4%) and more specific (78.6 vs 67.9%) than SET as a screening procedure. The positive predictive value of SPT was greater than that of SET (82.9 vs 75.0%), as was the negative predictive value (81.5 vs 73.0%). None of these differences was statistically significant; because of the relatively small sample size, our study was powered to show only equivalency. The results of our study suggest that the information obtained by the SET method of IDT is comparable to that obtained by SPT in terms of sensitivity, specificity, and overall performance and that both SET and SPT correlate well with nasal provocation testing for ragweed. Therefore, the decision as to which to use can be based on other factors, such as the practitioner's training, the desire for quantitative results, the desire for rapid results, and the type of treatment (i.e., immunotherapy or pharmacotherapy) that is likely to be chosen on the basis of test results.
Yamamoto, Kenyu; Yamazaki, Hideo; Kuroda, Chikazumi; Kubo, Tsugio; Oshima, Akira; Katsuda, Toshizo; Kuwano, Tadao; Takeda, Yoshihiro
2010-01-01
Background The use of high-density barium sulfate was recommended by the Japan Society of Gastroenterological Cancer Screening (JSGCS) in 2004. We evaluated the diagnostic validity of gastric cancer screening that used high-density barium sulfate. Methods The study subjects were 171 833 residents of Osaka, Japan who underwent gastric cancer screening tests at the Osaka Cancer Prevention and Detection Center during the period from 1 January 2000 through 31 December 2001. Screening was conducted using either high-density barium sulfate (n = 48 336) or moderate-density barium sulfate (n = 123 497). The subjects were followed up and their medical records were linked to those of the Osaka Cancer Registry through 31 December 2002. The results of follow-up during 1 year were defined as the gold standard, and test performance values were calculated. Results The sensitivity and specificity of the screening test using moderate-density barium sulfate were 92.3% and 91.0%, respectively, while the sensitivity and specificity of the high-density barium test were 91.8% and 91.4%, respectively. The results of area under receiver-operating-characteristic (ROC) curve analysis revealed no significant difference between the 2 screening tests. Conclusions Screening tests using high- and moderate-density barium sulfate had similar validity, as determined by sensitivity, specificity, and ROC curve analysis. PMID:20551581
Improved E-ELT subsystem and component specifications, thanks to M1 test facility
NASA Astrophysics Data System (ADS)
Dimmler, M.; Marrero, J.; Leveque, S.; Barriga, Pablo; Sedghi, B.; Kornweibel, N.
2014-07-01
During the last 2 years ESO has operated the "M1 Test Facility", a test stand consisting of a representative section of the E-ELT primary mirror equipped with 4 complete prototype segment subunits including sensors, actuators and control system. The purpose of the test facility is twofold: it serves to study and get familiar with component and system aspects like calibration, alignment and handling procedures and suitable control strategies on real hardware long before the primary mirror (hereafter M1) components are commissioned. Secondly, and of major benefit to the project, it offered the possibility to evaluate component and subsystem performance and interface issues in a system context in such detail, that issues could be identified early enough to feed back into the subsystem and component specifications. This considerably reduces risk and cost of the production units and allows refocusing the project team on important issues for the follow-up of the production contracts. Experiences are presented in which areas the results of the M1 Test Facility particularly helped to improve subsystem specifications and areas, where additional tests were adopted independent of the main test facility. Presented are the key experiences of the M1 Test Facility which lead to improved specifications or identified the need for additional testing outside of the M1 Test Facility.
Cohen, Daniel M; Russo, Michael E; Jaggi, Preeti; Kline, Jennifer; Gluckman, William; Parekh, Amisha
2015-07-01
Rapid detection of group A beta-hemolytic streptococcus (GAS) is used routinely to help diagnose and treat pharyngitis. However, available rapid antigen detection tests for GAS have relatively low sensitivity, and backup testing is recommended in children. Newer assays are more sensitive yet require excessive time for practical point-of-care use as well as laboratory personnel. The Alere i strep A test is an isothermal nucleic acid amplification test designed to offer highly sensitive results at the point of care within 8 min when performed by nonlaboratory personnel. The performance of the Alere i strep A test was evaluated in a multicenter prospective trial in a Clinical Laboratory Improvement Amendments (CLIA)-waived setting in comparison to bacterial culture in 481 children and adults. Compared to culture, the Aleri i strep A test had 96.0% sensitivity and 94.6% specificity. Discrepant results were adjudicated by PCR and found the Alere i strep A test to have 98.7% sensitivity and 98.5% specificity. Overall, the Alere i strep A test could provide a one-step, rapid, point-of-care testing method for GAS pharyngitis and obviate backup testing on negative results. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Diagnostic methods for insect sting allergy.
Hamilton, Robert G
2004-08-01
This review overviews advances from mid-2002 to the present in the validation and performance methods used in the diagnosis of Hymenoptera venom-induced immediate-type hypersensitivity. The general diagnostic algorithm for insect sting allergy is initially discussed with an examination of the AAAAI's 2003 revised practice parameter guidelines. Changes as a result of a greater recognition of skin test negative systemic reactors include repeat analysis of all testing and acceptance of serology as a complementary diagnostic test to the skin test. Original data examining concordance of venom-specific IgE results produced by the second-generation Pharmacia CAP System with the Johns Hopkins University radioallergosorbent test are presented. Diagnostic performance of honeybee venom-specific IgE assays used in clinical laboratories in North America is discussed using data from the Diagnostic Allergy Proficiency Survey conducted by the College of American Pathologists. Validity of venom-specific IgE antibody in postmortem blood specimens is demonstrated. The utility of alternative in-vivo (provocation) and in-vitro (basophil-based) diagnostic testing methods is critiqued. This overview supports the following conclusions. Improved practice parameter guidelines include serology and skin test as complementary in supporting a positive clinical history during the diagnostic process. Data are provided which support the analytical performance of commercially available venom-specific IgE antibody serology-based assays. Intentional sting challenge in-vivo provocation, in-vitro basophil flow cytometry (CD63, CD203c) based assays, and in-vitro basophil histamine and sulfidoleukotriene release assays have their utility in the study of difficult diagnostic cases, but their use will remain as supplementary, secondary diagnostic tests.
Sensitivity and Specificity of Eustachian Tube Function Tests in Adults
Doyle, William J.; Swarts, J. Douglas; Banks, Julianne; Casselbrant, Margaretha L; Mandel, Ellen M; Alper, Cuneyt M.
2013-01-01
Objective Determine if Eustachian Tube (ET) function (ETF) tests can identify ears with physician-diagnosed ET dysfunction (ETD) in a mixed population at high sensitivity and specificity and define the inter-relatedness of ETF test parameters. Methods ETF was evaluated using the Forced-Response, Inflation-Deflation, Valsalva and Sniffing tests in 15 control ears of adult subjects after unilateral myringotomy (Group I) and in 23 ears of 19 adult subjects with ventilation tubes inserted for ETD (Group II). Data were analyzed using logistic regression including each parameter independently and then a step-down Discriminant Analysis including all ETF test parameters to predict group assignment. Factor Analysis operating over all parameters was used to explore relatedness. Results The Discriminant Analysis identified 4 ETF test parameters (Valsalva, ET opening pressure, dilatory efficiency and % positive pressure equilibrated) that together correctly assigned ears to Group II at a sensitivity of 95% and a specificity of 83%. Individual parameters representing the efficiency of ET opening during swallowing showed moderately accurate assignments of ears to their respective groups. Three factors captured approximately 98% of the variance among parameters, the first had negative loadings of the ETF structural parameters, the second had positive loadings of the muscle-assisted ET opening parameters and the third had negative loadings of the muscle-assisted ET opening parameters and positive loadings of the structural parameters. Discussion These results show that ETF tests can correctly assign individual ears to physician-diagnosed ETD with high sensitivity and specificity and that ETF test parameters can be grouped into structural-functional categories. PMID:23868429
Salinas, María; Flores, Emilio; López-Garrigós, Maite; Díaz, Elena; Esteban, Patricia; Leiva-Salinas, Carlos
2017-01-01
To apply a continual improvement model to develop an algorithm for ordering laboratory tests to diagnose acute pancreatitis in a hospital emergency department. Quasi-experimental study using the continual improvement model (plan, do, check, adjust cycles) in 2 consecutive phases in emergency patients: amylase and lipase results were used to diagnose acute pancreatitis in the first phase; in the second, only lipase level was first determined; amylase testing was then ordered only if the lipase level fell within a certain range. We collected demographic data, number amylase and lipase tests ordered and the findings, final diagnosis, and the results of a questionnaire to evaluate satisfaction with emergency care. The first phase included 517 patients, of whom 20 had acute pancreatitis. For amylase testing sensitivity was 0.70; specificity, 0.85; positive predictive value (PPV), 17; and negative predictive value (NPV), 0.31. For lipase testing these values were sensitivity, 0.85; specificity, 0.96; PPV, 21, and NPV, 0.16. When both tests were done, sensitivity was 0.85; specificity 0.99; PPV, 85; and NPV, 0.15. The second phase included data for 4815 patients, 118 of whom had acute pancreatitis. The measures of diagnostic yield for the new algorithm were sensitivity, 0.92; specificity, 0.98; PPV, 46; and NPV, 0.08]. This study demonstrates a process for developing a protocol to guide laboratory testing in acute pancreatitis in the hospital emergency department. The proposed sequence of testing for pancreatic enzyme levels can be effective for diagnosing acute pancreatitis in patients with abdominal pain.
Hasan, J A; Huq, A; Nair, G B; Garg, S; Mukhopadhyay, A K; Loomis, L; Bernstein, D; Colwell, R R
1995-11-01
We report on the development and testing of two monoclonal antibody-based rapid immunodiagnostic test kits, BengalScreen, a coagglutination test, and Bengal DFA, a direct fluorescent-antibody test, for direct detection of Vibrio cholerae O139 synonym Bengal in clinical and environmental specimens. The BengalScreen test requires less than 5 min to complete and can be used in the field. Bengal DFA, being more sensitive than BengalScreen, requires only one reagent and less than 20 min for detection and enumeration of V. cholerae O139 synonym Bengal. In tests for specificity, all 40 strains of V. cholerae O139 reacted with both test kits, whereas 157 strains of heterologous species examined did not, yielding 100% specificity in this study. A field trial was conducted in with both BengalScreen and Bengal DFA, and the results were compared with those obtained by conventional culture methods. BengalScreen demonstrated a sensitivity of 95%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 94%. Results obtained by Bengal DFA, on the other hand, were 100% sensitive and 100% specific and yielded 100% positive and negative predictive values compared with culture methods. In a second evaluation, 93 stool specimens from Mexico that were negative for V. cholerae O139 by culture were also tested with both the BengalScreen and Bengal DFA kits. None of the 93 specimens were positive for V. cholerae O139 by both tests. A concentration method was optimized for screening of environmental water samples for V. cholerae O139 synonym Bengal with rapid test kits. BengalScreen results were unequivocally positive when water samples contained at least 2.0 x 10(3) CFU/ml, whereas Bengal DFA demonstrated an unequivocally positive reaction when the water sample contained at least 1.5 x 10(2) CFU/ml. When Bengal DFA was compared with conventional culture methods for enumeration of V. cholerae O139 synonym Bengal organisms, no difference was observed.
Westman, Mark E; Malik, Richard; Hall, Evelyn; Sheehy, Paul A; Norris, Jacqueline M
2017-02-01
Feline leukaemia virus (FeLV) can be a challenging infection to diagnose due to a complex feline host-pathogen relationship and occasionally unreliable test results. This study compared the accuracy of three point-of-care (PoC) FeLV p27 antigen test kits commonly used in Australia and available commercially worldwide (SNAP FIV/FeLV Combo, Witness FeLV/FIV and Anigen Rapid FIV/FeLV), using detection of FeLV provirus by an in-house real-time polymerase chain reaction (qPCR) assay as the diagnostic gold standard. Blood (n=563) and saliva (n=419) specimens were collected from a population of cats determined to include 491 FeLV-uninfected and 72 FeLV-infected individuals (45 progressive infections [p27 and qPCR positive], 27 regressive infections [p27 negative, qPCR positive]). Sensitivity and specificity using whole blood was 63% and 94% for SNAP Combo, 57% and 98% for Witness, and 57% and 98% for Anigen Rapid, respectively. SNAP Combo had a significantly lower specificity using blood compared to the other two kits (P=0.004 compared to Witness, P=0.007 compared to Anigen Rapid). False-positive test results occurred with all three kits using blood, and although using any two kits in parallel increased specificity, no combination of kits completely eliminated the occurrence of false-positive results. We therefore recommend FeLV proviral PCR testing for any cat that tests positive with a PoC FeLV antigen kit, as well as for any cat that has been potentially exposed to FeLV but tests negative with a FeLV antigen kit, before final assignment of FeLV status can be made with confidence. For saliva testing, sensitivity and specificity was 54% and 100%, respectively, for all three test kits. The reduced sensitivity of saliva testing compared to blood testing, although not statistically significant, suggests saliva testing with the current generation of PoC FeLV antigen kits is unsuitable for screening large populations of cats, such as in shelters. Copyright © 2016 Elsevier Ltd. All rights reserved.
Cervical VEMP threshold response curve in the identification of Ménière's disease.
Zhu, Yi; McPherson, James; Beatty, Charles; Driscoll, Colin; Neff, Brian; Eggers, Scott; Shepard, Neil T
2014-03-01
To investigate the sensitivity/specificity of a shift upward in the most sensitive frequency of the cervical vestibular evoked myogenic potential (cVEMP) threshold-response curve in the identification of Ménière's disease (MD). A secondary purpose was to investigate the clinical characteristics that had an impact on the sensitivity/specificity and to adjust the criteria for a positive shift upward in the cVEMP curve to maximize performance of the test. A retrospective review of patients diagnosed with MD and those without MD. Two hundred ninety-four patients met the inclusion criteria of symptom complaints of spontaneous events of vertigo and a full vestibular and balance evaluation with cVEMP threshold-response curve testing. Two hundred six of these patients were diagnosed with MD, and 88 patients were determined to be non-MD. Review of the patients' medical records was used to extract data on the results of the cVEMP curve, age, gender, duration from time of onset of spontaneous events, pure tone average from hearing test, and water caloric asymmetry. Student's t-test, χ² test, receiver operating characteristic (ROC) curve with area under the curve (AUC), Pearson correlation coefficient, and sensitivity/specificity from 2 × 2 tables were all used in the analysis. Basic sensitivity/specificity for a shift upward in the most sensitive frequency to 1000 Hz in the cVEMP threshold-response curve was 0.47/0.64 respectively. Clinical characteristics that were found to have a significant impact on the sensitivity/specificity were age equal to or above 60 yr and a caloric asymmetry ≥25%. Various combinations of age and caloric with the requirement of a shift upward in the cVEMP curve most sensitive frequency to 1000 Hz resulted in significant but modest improvements in sensitivity/specificity. However, the overall performance was not shown acceptable for routine clinical use with maximum sensitivity at 0.73. Therefore, placing an emphasis on specificity over sensitivity results showed specificity of 0.95 for those under 60 yr and 0.90 for those 60 yr of age or older with sensitivity at 0.20, but only in the context of a ≥25% caloric asymmetry. We recommend the use of the shift upward to 1000 Hz with a caloric asymmetry as the clinical protocol to maximize the use of the cVEMP threshold-response curve for assistance in the identification of MD, in the context of a ≥25% caloric asymmetry. This implies that if the test is negative no interpretation of identification of MD can be made. If the test is positive the results can be used to increase the argument for MD since the probability of the result being a false positive is only 5-10%. American Academy of Audiology.
Kam, K Y Ronald; Ong, Hon Shing; Bunce, Catey; Ogunbowale, Lola; Verma, Seema
2015-09-01
To estimate the diagnostic accuracy (sensitivity and specificity) of the AdenoPlus point-of-care adenoviral test compared to PCR in an ophthalmic accident and emergency service. These findings were compared with those of a previous study. This was a prospective diagnostic accuracy study on 121 patients presenting to an emergency eye unit with a clinical picture of acute adenoviral conjunctivitis. AdenoPlus testing was carried out on one eye of each patient and a PCR analysis was also performed on a swab taken from the same eye. AdenoPlus and PCR results were interpreted by masked personnel. Sensitivity and specificity for the AdenoPlus test were calculated using PCR results as the reference standard. 121 patients were enrolled and 109 met the inclusion criteria. 43 patients (39.4%) tested positive for adenovirus by PCR analysis. The sensitivity of the AdenoPlus swab in detecting adenovirus was 39.5% (17/43, 95% CI 26% to 54%) and specificity was 95.5% (63/66, 95% CI 87% to 98%) compared to PCR. The AdenoPlus test has a high specificity for diagnosing adenoviral conjunctivitis, but in this clinical setting, we could not reproduce the high sensitivity that has been previously published. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
[Roaming through methodology. XXXII. False test results].
van der Weijden, T; van den Akker, M
2001-05-12
The number of requests for diagnostic tests is rising. This leads to a higher chance of false test results. The false-negative proportion of a test is the proportion of negative test results among the diseased subjects. The false-positive proportion is the proportion of positive test results among the healthy subjects. The calculation of the false-positive proportion is often incorrect. For example, instead of 1 minus the specificity it is calculated as 1 minus the positive predictive value. This can lead to incorrect decision-making with respect to the application of the test. Physicians must apply diagnostic tests in such a way that the risk of false test results is minimal. The patient should be aware that a perfectly conclusive diagnostic test is rare in medical practice, and should more often be informed of the implications of false-positive and false-negative test results.
... are most likely to get this disease. Normal Results A normal (negative) result usually means you have ... meaning of your specific test results. What Abnormal Results Mean An abnormal (positive) result usually means you ...
Diagnostic performance characteristics of a rapid field test for anthrax in cattle.
Muller, Janine; Gwozdz, Jacek; Hodgeman, Rachel; Ainsworth, Catherine; Kluver, Patrick; Czarnecki, Jill; Warner, Simone; Fegan, Mark
2015-07-01
Although diagnosis of anthrax can be made in the field with a peripheral blood smear, and in the laboratory with bacterial culture or molecular based tests, these tests require either considerable experience or specialised equipment. Here we report on the evaluation of the diagnostic sensitivity and specificity of a simple and rapid in-field diagnostic test for anthrax, the anthrax immunochromatographic test (AICT). The AICT detects the protective antigen (PA) component of the anthrax toxin present within the blood of an animal that has died from anthrax. The test provides a result in 15min and offers the advantage of avoiding the necessity for on-site necropsy and subsequent occupational risks and environmental contamination. The specificity of the test was determined by testing samples taken from 622 animals, not infected with Bacillus anthracis. Diagnostic sensitivity was estimated on samples taken from 58 animals, naturally infected with B. anthracis collected over a 10-year period. All samples used to estimate the diagnostic sensitivity and specificity of the AICT were also tested using the gold standard of bacterial culture. The diagnostic specificity of the test was estimated to be 100% (99.4-100%; 95% CI) and the diagnostic sensitivity was estimated to be 93.1% (83.3-98.1%; 95% CI) (Clopper-Pearson method). Four samples produced false negative AICT results. These were among 9 samples, all of which tested positive for B. anthracis by culture, where there was a time delay between collection and testing of >48h and/or the samples were collected from animals that were >48h post-mortem. A statistically significant difference (P<0.001; Fishers exact test) was found between the ability of the AICT to detect PA in samples from culture positive animals <48h post-mortem, 49 of 49, Se=100% (92.8-100%; 95% CI) compared with samples tested >48h post-mortem 5 of 9 Se=56% (21-86.3%; 95% CI) (Clopper-Pearson method). Based upon these results a post hoc cut-off for use of the AICT of 48h post-mortem was applied, Se=100% (92.8-100%; 95% CI) and Sp=100% (99.4-100%; 95% CI). The high diagnostic sensitivity and specificity and the simplicity of the AICT enables it to be used for active surveillance in areas with a history of anthrax, or used as a preliminary tool in investigating sudden, unexplained death in cattle. Copyright © 2015 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Judkoff, R.; Neymark, J.
2013-07-01
ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs applies the IEA BESTEST building thermal fabric test cases and example simulation results originally published in 1995. These software accuracy test cases and their example simulation results, which comprise the first test suite adapted for the initial 2001 version of Standard 140, are approaching their 20th anniversary. In response to the evolution of the state of the art in building thermal fabric modeling since the test cases and example simulation results were developed, work is commencing to update the normative test specification and themore » informative example results.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Judkoff, R.; Neymark, J.
2013-07-01
ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs applies the IEA BESTEST building thermal fabric test cases and example simulation results originally published in 1995. These software accuracy test cases and their example simulation results, which comprise the first test suite adapted for the initial 2001 version of Standard 140, are approaching their 20th anniversary. In response to the evolution of the state of the art in building thermal fabric modeling since the test cases and example simulation results were developed, work is commencing to update the normative test specification and themore » informative example results.« less
Lubell, Yoel; Althaus, Thomas; Blacksell, Stuart D.; Paris, Daniel H.; Mayxay, Mayfong; Pan-Ngum, Wirichada; White, Lisa J.; Day, Nicholas P. J.; Newton, Paul N.
2016-01-01
Background Malaria accounts for a small fraction of febrile cases in increasingly large areas of the malaria endemic world. Point-of-care tests to improve the management of non-malarial fevers appropriate for primary care are few, consisting of either diagnostic tests for specific pathogens or testing for biomarkers of host response that indicate whether antibiotics might be required. The impact and cost-effectiveness of these approaches are relatively unexplored and methods to do so are not well-developed. Methods We model the ability of dengue and scrub typhus rapid tests to inform antibiotic treatment, as compared with testing for elevated C-Reactive Protein (CRP), a biomarker of host-inflammation. Using data on causes of fever in rural Laos, we estimate the proportion of outpatients that would be correctly classified as requiring an antibiotic and the likely cost-effectiveness of the approaches. Results Use of either pathogen-specific test slightly increased the proportion of patients correctly classified as requiring antibiotics. CRP testing was consistently superior to the pathogen-specific tests, despite heterogeneity in causes of fever. All testing strategies are likely to result in higher average costs, but only the scrub typhus and CRP tests are likely to be cost-effective when considering direct health benefits, with median cost per disability adjusted life year averted of approximately $48 USD and $94 USD, respectively. Conclusions Testing for viral infections is unlikely to be cost-effective when considering only direct health benefits to patients. Testing for prevalent bacterial pathogens can be cost-effective, having the benefit of informing not only whether treatment is required, but also as to the most appropriate antibiotic; this advantage, however, varies widely in response to heterogeneity in causes of fever. Testing for biomarkers of host inflammation is likely to be consistently cost-effective despite high heterogeneity, and can also offer substantial reductions in over-use of antimicrobials in viral infections. PMID:27027303
... count results, such as chronic kidney disease Normal Results Blood counts may vary with altitude. In general, ... meaning of your specific test results. What Abnormal Results Mean High RBC, hemoglobin, or hematocrit may be ...
... urine To diagnose a urinary tract infection Normal Results Normal urine varies in color from almost colorless ... meaning of your specific test results. What Abnormal Results Mean Abnormal results may mean you have an ...
Test Anxiety and College Students with Attention Deficit Hyperactivity Disorder
ERIC Educational Resources Information Center
Nelson, Jason M.; Lindstrom, Will; Foels, Patricia A.
2014-01-01
Test anxiety was examined in college students with and without attention deficit hyperactivity disorder (ADHD). Results indicated that, relative to college students without ADHD, college students with ADHD reported higher total test anxiety as well as specific aspects of test anxiety, including worry (i.e., cognitive aspects of test anxiety) and…
Elliott, D.G.; Applegate, L.J.; Murray, A.L.; Purcell, M.K.; McKibben, C.L.
2013-01-01
No gold standard assay exhibiting error-free classification of results has been identified for detection of Renibacterium salmoninarum, the causative agent of salmonid bacterial kidney disease. Validation of diagnostic assays for R. salmoninarum has been hindered by its unique characteristics and biology, and difficulties in locating suitable populations of reference test animals. Infection status of fish in test populations is often unknown, and it is commonly assumed that the assay yielding the most positive results has the highest diagnostic accuracy, without consideration of misclassification of results. In this research, quantification of R. salmoninarum in samples by bacteriological culture provided a standardized measure of viable bacteria to evaluate analytical performance characteristics (sensitivity, specificity and repeatability) of non-culture assays in three matrices (phosphate-buffered saline, ovarian fluid and kidney tissue). Non-culture assays included polyclonal enzyme-linked immunosorbent assay (ELISA), direct smear fluorescent antibody technique (FAT), membrane-filtration FAT, nested polymerase chain reaction (nested PCR) and three real-time quantitative PCR assays. Injection challenge of specific pathogen-free Chinook salmon, Oncorhynchus tshawytscha (Walbaum), with R. salmoninarum was used to estimate diagnostic sensitivity and specificity. Results did not identify a single assay demonstrating the highest analytical and diagnostic performance characteristics, but revealed strengths and weaknesses of each test.
Luzy, Anne-Pascale; Orsini, Nicolas; Linget, Jean-Michel; Bouvier, Guy
2013-11-01
Twenty-two of Galderma's proprietary compounds were tested in the GADD45α-GFP 'GreenScreen HC' assay (GS), the SOS-ChromoTest and the Mini-Ames to evaluate GSs performance for early genotoxicity screening purposes. Forty more characterized compounds were also tested, including antibiotics: metronidazole, clindamycin, tetracycline, lymecycline and neomycin; and catecholamines: resorcinol mequinol, hydroquinone, one aneugen carbendazim, one corticoid dexamethasone, one peroxisome proliferator-activated receptor rosiglitazone, one pesticide carbaryl and two further proprietary molecules with in vitro genotoxicity data. With proprietary molecules, this study concluded that the GS renders the SOS-ChromoTest obsolete for in vitro screening. The GS confirmed all results of the Mini-Ames test (100% concordance). Compared with the micronucleus test, the GS showed a concordance of 82%. With known compounds, the GS ranked the potency of positive results for catecholamines in accordance with other genotoxicity tests and showed very reproducible results. It confirmed positive results for carbendazim, for tetracycline antibiotics and for carbaryl. The GS produced negative results for metronidazole, a nitroreduction-specific bacterial mutagen, for dexamethasone (a non-genotoxic apoptosis inducer), for rosiglitazone (a GADD45γ promoter inducer) and for clindamycin and neomycin (inhibitors of macromolecular synthesis in bacteria). As such, the GS appears to be a reproducible, robust, specific and sensitive test for genotoxicity screening. Copyright © 2012 John Wiley & Sons, Ltd.
A look at the purchase and use of home pregnancy-test kits.
Coons, S J
1989-04-01
A study was conducted to obtain information regarding the purchase and use of home pregnancy-test kits. Questionnaires were distributed to 438 women entering a family-planning clinic in the fall of 1987. A total of 153 questionnaires were completed and returned, providing a response rate of 34.9%. Results indicated that nearly 40% of the respondents had used a home pregnancy-test kit at least once. Of those who had used a home pregnancy-test kit, the majority did so because of "the speed of obtaining results" or "convenience." Although nearly 87% of the pregnancy-test kits had been purchased in a pharmacy, pharmacists played only a minor role in the decision-making process concerning purchase and use. Some three-fourths of the subjects listed "information on the side of the package," "price," or "advertisements" as the most important factor in the selection of a specific brand of test kit. Only about 7% of the subjects selected "recommendation of the pharmacist" as the most important factor. The results suggest that pharmacists could be doing more to promote the appropriate use of self-testing products, specifically home pregnancy-test kits.
[Symptomatic sinus dysfunction. A new use of electrophysiology].
Graux, P; Jacquemart, T; Carlioz, R; Lemaire, N; Dutoit, A; Croccel, L
1993-06-01
The authors undertook a prospective electrophysiological study of 950 patients: 53 subjects considered to be "controls" since they were free of any history of syncope or faintness were identified, as well as 39 symptomatic subjects with a strong suspicion of sinus dysfunction, since no other detectable cause of fainting episodes was found by extracardiac investigation, 24 hour ECG nor electrophysiology. Following the creation of a computerised tool enabling not only the entry of indirect tests, processing, averaging of results, printing and memorization, but also assistance in interpretation, several electrophysiological parameters were used: heart rate and existence of sinus arrhythmia, Strauss tests with adjusted data or not, effective nodal refractory period, Guize, Narula and Mandel tests, and an atropine (0.03 mg/kg) test which was performed only in the symptomatic group. These tests were studied by single-variate and correlative analysis to define their normal ranges, their critical values and their dependence or independence. The performance of each test (i.e. its efficiency, and the specificity and sensitivity of each critical value) was measured. Tests found to be most useful (specificity and efficiency > 90%) were as follows: Mandel test = CSRT > or = 534 ms, Narula test = TECASA > or = 339 ms, heart rate < or = 55/min, type II, IIa and chaotic Strauss curve associated with a pathological Guize test. The combination of these tests in this algorithm resulted in an increase in sensitivity to 84%, at the price of a very moderate fall in specificity to 87%.(ABSTRACT TRUNCATED AT 250 WORDS)
Stauffer, Fritz; Haber, Heinrich; Rieger, Armin; Mutschlechner, Robert; Hasenberger, Petra; Tevere, Vincent J.; Young, Karen K. Y.
1998-01-01
An easy-to-handle Mycobacterium-specific PCR assay for detection of the presence of a wide range of mycobacterial species in clinical samples was evaluated. The performance of the genus probe was compared with the performance of probes specific for Mycobacterium tuberculosis and Mycobacterium avium and with that of standard culture. In addition, the utility of an internal control in monitoring amplification inhibitors was studied. Of 545 respiratory and 325 nonrespiratory specimens (a total of 870 specimens), 58 (6.7%) showed the presence of amplification inhibitors, as determined by a negative result for the internal control. Of these 58 specimens, 31 (53%) were stool specimens; other material, even citrate blood after lysis of erythrocytes, did not pose a problem with regard to inhibition of PCR amplification. Eighty-one of the remaining 812 specimens had a positive Mycobacterium culture result. Of these culture-positive specimens, 58 (71.6%) showed a positive result with the Mycobacterium genus-specific probe. Seventy-two samples had a positive result with the Mycobacterium-specific probe but a negative culture result. Of these 72 samples, 26 samples were regarded as true positive, either because the M. tuberculosis- or M. avium-specific probe was also positive at the same time or because other specimens from the same patient taken at the same time were culture positive. The sensitivity of the Mycobacterium-specific probe was 78.5% and the specificity was 93.5%. This study showed that pretesting of clinical specimens for mycobacteria to the genus level with a Mycobacterium-specific probe offers the routine clinical laboratory the possibility of detecting tuberculous and nontuberculous mycobacteria with one test. Furthermore, specimens testing positive with the genus-specific probe can be immediately identified with species-specific probes. PMID:9508282
Kenyon, Lisa K.; Elliott, James M; Cheng, M. Samuel
2016-01-01
Purpose/Background Despite the availability of various field-tests for many competitive sports, a reliable and valid test specifically developed for use in men's gymnastics has not yet been developed. The Men's Gymnastics Functional Measurement Tool (MGFMT) was designed to assess sport-specific physical abilities in male competitive gymnasts. The purpose of this study was to develop the MGFMT by establishing a scoring system for individual test items and to initiate the process of establishing test-retest reliability and construct validity. Methods A total of 83 competitive male gymnasts ages 7-18 underwent testing using the MGFMT. Thirty of these subjects underwent re-testing one week later in order to assess test-retest reliability. Construct validity was assessed using a simple regression analysis between total MGFMT scores and the gymnasts’ USA-Gymnastics competitive level to calculate the coefficient of determination (r2). Test-retest reliability was analyzed using Model 1 Intraclass correlation coefficients (ICC). Statistical significance was set at the p<0.05 level. Results The relationship between total MGFMT scores and subjects’ current USA-Gymnastics competitive level was found to be good (r2 = 0.63). Reliability testing of the MGFMT composite test score showed excellent test-retest reliability over a one-week period (ICC = 0.97). Test-retest reliability of the individual component tests ranged from good to excellent (ICC = 0.75-0.97). Conclusions The results of this study provide initial support for the construct validity and test-retest reliability of the MGFMT. Level of Evidence Level 3 PMID:27999723
Money, Deborah; Dobson, Simon; Cole, Lesley; Karacabeyli, Eda; Blondel-Hill, Edith; Milner, Ruth; Thomas, Eva
2008-09-01
To evaluate the sensitivity, specificity, and feasibility of a rapid real-time polymerase chain reaction (PCR) test for group B streptococcus (GBS) completed during labour, compared with the standard culture test performed at 35 to 37 weeks' gestation. Women presenting to the maternity unit for term vaginal delivery had two vaginal/rectal samples collected. One swab was tested using a rapid PCR method (IDI-Strep B, Infectio Diagnostic [IDI] Inc., Sainte-Foy QC ), and the other was cultured after enrichment (intrapartum culture). Comparisons were made between these results and those of a culture-based screen at 35 to 37 weeks' gestation. Of the 190 women enrolled, 85% had results of the standard screen at 35 to 37 weeks available for comparison. The sensitivity and specificity of the standard 35- to 37-week screen were 84.3% (95% confidence interval [CI], 71.4-93.0) and 93.2% (95% CI 86.5-97.2) respectively, whereas the sensitivity and specificity of the rapid PCR were 90.7% (95% CI 79.7-96.9) and 97.6% (95% CI 93.1-99.5), respectively. The median reporting time for the rapid PCR test was 99 minutes (range 50-255). Results were available more than four hours before delivery in 81% of cases. In this Canadian centre, a rapid PCR test done at the time of labour (IDI-Strep B) demonstrated high sensitivity and specificity, comparable to the 35- to 37-week screen. The time to reporting results was acceptably short, allowing for timely administration of intrapartum prophylactic antibiotics.
Encoding Specificity in the Recall of Pictures and Words in Children and Adults.
ERIC Educational Resources Information Center
Ackerman, Brian P.
1981-01-01
Two experiments, using pictorial or verbal stimuli, were designed to test encoding among young children and adults. In both experiments, results indicated progressively smaller encoding specificity effects with increasing age. Comparisons of recall patterns were conducted to ensure that encoding differences accounted for results. (Author/DB)
A Nuclear Cryogenic Propulsion Stage for Near-Term Space Missions
NASA Technical Reports Server (NTRS)
Houts, Michael G.; Kim, Tony; Emrich, William J.; Hickman, Robert R.; Broadway, Jeramie W.; Gerrish, Harold P.; Adams, Robert B.; Bechtel, Ryan D.; Borowski, Stanley K.; George, Jeffrey A.
2013-01-01
Development efforts in the United States have demonstrated the viability and performance potential of NTP systems. For example, Project Rover (1955 - 1973) completed 22 high power rocket reactor tests. Peak performances included operating at an average hydrogen exhaust temperature of 2550 K and a peak fuel power density of 5200 MW/m3 (Pewee test), operating at a thrust of 930 kN (Phoebus-2A test), and operating for 62.7 minutes on a single burn (NRXA6 test). Results from Project Rover indicated that an NTP system with a high thrust-toweight ratio and a specific impulse greater than 900 s would be feasible. Excellent results have also been obtained by Russia. Ternary carbide fuels developed in Russia may have the potential for providing even higher specific impulses.
Results and conclusions: perception sensor study for high speed autonomous operations
NASA Astrophysics Data System (ADS)
Schneider, Anne; LaCelle, Zachary; Lacaze, Alberto; Murphy, Karl; Close, Ryan
2016-05-01
Previous research has presented work on sensor requirements, specifications, and testing, to evaluate the feasibility of increasing autonomous vehicle system speeds. Discussions included the theoretical background for determining sensor requirements, and the basic test setup and evaluation criteria for comparing existing and prototype sensor designs. This paper will present and discuss the continuation of this work. In particular, this paper will focus on analyzing the problem via a real-world comparison of various sensor technology testing results, as opposed to previous work that utilized more of a theoretical approach. LADAR/LIDAR, radar, visual, and infrared sensors are considered in this research. Results are evaluated against the theoretical, desired perception specifications. Conclusions for utilizing a suite of perception sensors, to achieve the goal of doubling ground vehicle speeds, is also discussed.
Gross, H; Kling, A; Henry, G; Herndon, C; Lavretsky, H
1996-01-01
A retrospective study of 20 patients with mild traumatic brain injury (MTBI) examined brain regions of interest by comparing [18F]-2-deoxyglucose PET, neuropsychological test results, and continuing behavioral dysfunction. Abnormal local cerebral metabolic rates (rLCMs) were most prominent in midtemporal, anterior cingulate, precuneus, anterior temporal, frontal white, and corpus callosum brain regions. Abnormal rLCMs were significantly correlated statistically with 1) overall clinical complaints, most specifically with inconsistent attention/concentration and 2) overall neuropsychological test results. The authors conclude that 1) even mild TBI may result in continuing brain behavioral deficits; 2) PET can help elucidate dysfunctional brain circuitry in neurobehavioral disorders; and 3) specific brain areas may correlate with deficits in daily neurobehavioral functioning and neuropsychological test findings.
Keller, Lisa A; Clauser, Brian E; Swanson, David B
2010-12-01
In recent years, demand for performance assessments has continued to grow. However, performance assessments are notorious for lower reliability, and in particular, low reliability resulting from task specificity. Since reliability analyses typically treat the performance tasks as randomly sampled from an infinite universe of tasks, these estimates of reliability may not be accurate. For tests built according to a table of specifications, tasks are randomly sampled from different strata (content domains, skill areas, etc.). If these strata remain fixed in the test construction process, ignoring this stratification in the reliability analysis results in an underestimate of "parallel forms" reliability, and an overestimate of the person-by-task component. This research explores the effect of representing and misrepresenting the stratification appropriately in estimation of reliability and the standard error of measurement. Both multivariate and univariate generalizability studies are reported. Results indicate that the proper specification of the analytic design is essential in yielding the proper information both about the generalizability of the assessment and the standard error of measurement. Further, illustrative D studies present the effect under a variety of situations and test designs. Additional benefits of multivariate generalizability theory in test design and evaluation are also discussed.
Majlesi, Javid; Togay, Halit; Unalan, Halil; Toprak, Sadk
2008-04-01
An accurate and specific diagnosis prevents the recurrences of low back pain and chronic spinal pain. The physical examination is the most useful tool to diagnosis. The examiner must aim to determine the exact tissue that pain arises from to make the specific diagnosis. Lumbar disc herniation is 1 disease that physical examination, symptoms, and findings on imaging technique do not always correlate with each other. The Straight Leg Raising (SLR) test has been used as the primary test to diagnosis lumbar disc herniations and found to have high correlation with findings on operation since its sensitivity is high in only disc herniations leading to root compression that may eventually need operation. More sensitive test, like the Slump, might be used in herniations in which the SLR is negative. The Slump test is really a variant of the SLR and the Lasègue's tests performed in the seated position and is a progressive series of maneuvers designed to place the sciatic nerve roots under increasing tension. At each step in the procedure, the patient informs the examiner what is being felt and whether radicular pain is produced. As a result, the Slump test applies traction to the nerve roots by incorporating spinal and hip joint flexion into the leg raising and would warn the examiner of the presence of nerve root compression when there is a negative SLR test. This study measured the sensitivity and specificity of the Slump test and compare it with the SLR test in patients with and without lumbar disc herniations. A prospective case control study of 75 patients with complaints suggestive of lumbar disc herniation was carried out in the outpatient clinics of the neurosurgery department of a state teaching hospital. Seventy-five referred or self-admitted patients with low back, leg, or low back and leg pain who had results of magnetic resonance imaging (MRI) of the lumbar spine were included in the study. Thirty-eight patients had signs of herniation demonstrated by MRI. Control patients (n = 37) had no disc bulges or herniations on MRI. Both the Slump and SLR tests were performed during the assessment of all the patients by the second author. The MRI results were assessed and recorded by the first author. The Slump test was found to be more sensitive (0.84) than the SLR (0.52) in the patients with lumbar disc herniations. However, the SLR was found to be a slightly more specific test (0.89) than the Slump test (0.83). The Slump test might be used more frequently as a sensitive physical examination tool in patients with symptoms of lumbar disc herniations. In contrast, owing to its higher specificity, the SLR test may especially help identify patients who have herniations with root compression requiring surgery.
Rapid diagnostic tests for typhoid and paratyphoid (enteric) fever
Wijedoru, Lalith; Mallett, Sue; Parry, Christopher M
2017-01-01
Background Differentiating both typhoid (Salmonella Typhi) and paratyphoid (Salmonella Paratyphi A) infection from other causes of fever in endemic areas is a diagnostic challenge. Although commercial point-of-care rapid diagnostic tests (RDTs) for enteric fever are available as alternatives to the current reference standard test of blood or bone marrow culture, or to the widely used Widal Test, their diagnostic accuracy is unclear. If accurate, they could potentially replace blood culture as the World Health Organization (WHO)-recommended main diagnostic test for enteric fever. Objectives To assess the diagnostic accuracy of commercially available rapid diagnostic tests (RDTs) and prototypes for detecting Salmonella Typhi or Paratyphi A infection in symptomatic persons living in endemic areas. Search methods We searched the Cochrane Infectious Diseases Group Specialized Register, MEDLINE, Embase, Science Citation Index, IndMED, African Index Medicus, LILACS, ClinicalTrials.gov, and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) up to 4 March 2016. We manually searched WHO reports, and papers from international conferences on Salmonella infections. We also contacted test manufacturers to identify studies. Selection criteria We included diagnostic accuracy studies of enteric fever RDTs in patients with fever or with symptoms suggestive of enteric fever living in endemic areas. We classified the reference standard used as either Grade 1 (result from a blood culture and a bone marrow culture) or Grade 2 (result from blood culture and blood polymerase chain reaction, or from blood culture alone). Data collection and analysis Two review authors independently extracted the test result data. We used a modified QUADAS-2 extraction form to assess methodological quality. We performed a meta-analysis when there were sufficient studies for the test and heterogeneity was reasonable. Main results Thirty-seven studies met the inclusion criteria and included a total of 5080 participants (range 50 to 1732). Enteric fever prevalence rates in the study populations ranged from 1% to 75% (median prevalence 24%, interquartile range (IQR) 11% to 46%). The included studies evaluated 16 different RDTs, and 16 studies compared two or more different RDTs. Only three studies used the Grade 1 reference standard, and only 11 studies recruited unselected febrile patients. Most included studies were from Asia, with five studies from sub-Saharan Africa. All of the RDTs were designed to detect S.Typhi infection only. Most studies evaluated three RDTs and their variants: TUBEX in 14 studies; Typhidot (Typhidot, Typhidot-M, and TyphiRapid-Tr02) in 22 studies; and the Test-It Typhoid immunochromatographic lateral flow assay, and its earlier prototypes (dipstick, latex agglutination) developed by the Royal Tropical Institute, Amsterdam (KIT) in nine studies. Meta-analyses showed an average sensitivity of 78% (95% confidence interval (CI) 71% to 85%) and specificity of 87% (95% CI 82% to 91%) for TUBEX; and an average sensitivity of 69% (95% CI 59% to 78%) and specificity of 90% (95% CI 78% to 93%) for all Test-It Typhoid and prototype tests (KIT). Across all forms of the Typhidot test, the average sensitivity was 84% (95% CI 73% to 91%) and specificity was 79% (95% CI 70% to 87%). When we based the analysis on the 13 studies of the Typhidot test that either reported indeterminate test results or where the test format means there are no indeterminate results, the average sensitivity was 78% (95% CI 65% to 87%) and specificity was 77% (95% CI 66% to 86%). We did not identify any difference in either sensitivity or specificity between TUBEX, Typhidot, and Test-it Typhoid tests when based on comparison to the 13 Typhidot studies where indeterminate results are either reported or not applicable. If TUBEX and Test-it Typhoid are compared to all Typhidot studies, the sensitivity of Typhidot was higher than Test-it Typhoid (15% (95% CI 2% to 28%), but other comparisons did not show a difference at the 95% level of CIs. In a hypothetical cohort of 1000 patients presenting with fever where 30% (300 patients) have enteric fever, on average Typhidot tests reporting indeterminate results or where tests do not produce indeterminate results will miss the diagnosis in 66 patients with enteric fever, TUBEX will miss 66, and Test-It Typhoid and prototype (KIT) tests will miss 93. In the 700 people without enteric fever, the number of people incorrectly diagnosed with enteric fever would be 161 with Typhidot tests, 91 with TUBEX, and 70 with Test-It Typhoid and prototype (KIT) tests. The CIs around these estimates were wide, with no difference in false positive results shown between tests. The quality of the data for each study was evaluated using a standardized checklist called QUADAS-2. Overall, the certainty of the evidence in the studies that evaluated enteric fever RDTs was low. Authors' conclusions In 37 studies that evaluated the diagnostic accuracy of RDTs for enteric fever, few studies were at a low risk of bias. The three main RDT tests and variants had moderate diagnostic accuracy. There was no evidence of a difference between the average sensitivity and specificity of the three main RDT tests. More robust evaluations of alternative RDTs for enteric fever are needed. The accuracy of rapid diagnostic tests for detecting typhoid and paratyphoid (enteric) fever Cochrane researchers assessed the accuracy of commercially-available rapid diagnostic tests and their prototypes (including TUBEX, Typhidot, Typhidot-M, Test-it Typhoid, and other tests) for detecting typhoid and paratyphoid (enteric) fever in people living in countries where the estimated number of individuals with the disease at any one time is greater than 10 per 100,000 population. If accurate, they could replace the current World Health Organization (WHO)-recommended diagnostic test: culture (growing the bacteria that causes the infection from a patient’s blood or bone marrow). Background Typhoid fever and paratyphoid fever are infections caused by the bacteria Salmonella Typhi and Salmonella Paratyphi A respectively. The term ‘enteric fever’ is used to describe both infections. Enteric fever can be difficult to diagnose as the signs and symptoms are similar to those of other infectious diseases that cause fever such as malaria. The recommended test to confirm if a person has enteric fever is to grow the Salmonella from their blood. It takes at least 48 hours to give a result, so cannot help healthcare workers make a diagnosis the same day the blood culture is taken. Blood cultures may give a negative result even though a person has enteric fever. The test also requires a laboratory and trained staff, which are often unavailable in communities where enteric fever is common. Rapid diagnostic tests (RDTs) are designed to be easy to use, and to deliver a quick result without the need for a blood culture laboratory. The cost of an enteric fever RDT would be significantly less than a blood culture, and requires less training to perform. Study characteristics Cochrane researchers searched the available literature up to 4 March 2016 and included 37 studies. Most studies recruited participants from South Asia. Most participants were adults, with 22 studies including children. All of the RDTs evaluated detected Salmonella Typhi (typhoid fever) only. Quality of the evidence The Cochrane researchers evaluated the quality of the data for each study using a standardized checklist called QUADAS-2. High quality studies that compared different types of RDT in the same patients were few in number. Two-thirds of the included studies did not evaluate the RDTs in the context of patients who are typically tested for the disease. Many studies utilized a particular study design (a case control study) which risks overestimating RDT accuracy. In the studies evaluating the Typhidot RDT, it was often unclear how many test results were indeterminate, when the test cannot distinguish a current episode of infection from a previous disease episode. Overall, the certainty of the evidence in the studies that evaluated enteric fever RDTs was low. Key results Sensitivity indicates the percentage of patients with a positive test result who are correctly diagnosed with disease. Specificity indicates the percentage of patients who are correctly identified as not having disease. TUBEX showed an average sensitivity of 78% and specificity of 87%. Typhidot studies, grouped together to include Typhidot, Typhidot-M, and TyphiRapid-Tr02, showed an average sensitivity of 84% and specificity of 79%. When Typhidot studies with clear reporting of indeterminate results are considered, the average sensitivity and specificity of Typhidot was 78% and 77% respectively. Test-It Typhoid and prototypes (KIT) showed an average sensitivity of 69% and specificity of 90%. Based on these results, in 1000 patients with fever where 30% (300 patients) have enteric fever, we would expect Typhidot tests reporting indeterminate results or where tests do not produce indeterminate results to, on average, miss the diagnosis (give a false negative result) in 66 patients with enteric fever, TUBEX to miss 66, and Test-It Typhoid and prototypes (KIT) to miss 93. In the 700 people without enteric fever, the number of people incorrectly given a diagnosis of enteric fever (a false positive result) would be on average 161 with these Typhidot tests, 91 with TUBEX, and 70 with the Test-It Typhoid and prototypes (KIT). These differences in the number of false negative and false positive results in patients from the different tests are not statistically important. The RDTs evaluated are not sufficiently accurate to replace blood culture as a diagnostic test for enteric fever. PMID:28545155
Evaluation of a prototype flow cytometry test for serodiagnosis of canine visceral leishmaniasis.
Ker, Henrique Gama; Coura-Vital, Wendel; Aguiar-Soares, Rodrigo Dian de Oliveira; Roatt, Bruno Mendes; das Dores Moreira, Nádia; Carneiro, Cláudia Martins; Machado, Evandro Marques de Menezes; Teixeira-Carvalho, Andréa; Martins-Filho, Olindo Assis; Giunchetti, Rodolfo Cordeiro; Araújo, Márcio Sobreira Silva; Coelho, Eduardo Antonio Ferraz; da Silveira-Lemos, Denise; Reis, Alexandre Barbosa
2013-12-01
Diagnosing canine visceral leishmaniasis (CVL) is a critical challenge since conventional immunoserological tests still present some deficiencies. The current study evaluated a prototype flow cytometry serology test, using antigens and fluorescent antibodies that had been stored for 1 year at 4°C, on a broad range of serum samples. Noninfected control dogs and Leishmania infantum-infected dogs were tested, and the prototype test showed excellent performance in differentiating these groups with high sensitivity, specificity, positive and negative predictive values, and accuracy (100% in all analyses). When the CVL group was evaluated according to the dogs' clinical status, the prototype test showed outstanding accuracy in all groups with positive serology (asymptomatic II, oligosymptomatic, and symptomatic). However, in dogs which had positive results by PCR-restriction fragment length polymorphism (RFLP) but negative results by conventional serology (asymptomatic I), serological reactivity was not observed. Additionally, sera from 40 dogs immunized with different vaccines (Leishmune, Leish-Tec, or LBSap) did not present serological reactivity in the prototype test. Eighty-eight dogs infected with other pathogens (Trypanosoma cruzi, Leishmania braziliensis, Ehrlichia canis, and Babesia canis) were used to determine cross-reactivity and specificity, and the prototype test performed well, particularly in dogs infected with B. canis and E. canis (100% and 93.3% specificities, respectively). In conclusion, our data reinforce the potential of the prototype test for use as a commercial kit and highlight its outstanding performance even after storage for 1 year at 4°C. Moreover, the prototype test efficiently provided accurate CVL serodiagnosis with an absence of false-positive results in vaccinated dogs and minor cross-reactivity against other canine pathogens.
Lozano, Oscar M; Rojas, Antonio J; Pérez, Cristino; González-Sáiz, Francisco; Ballesta, Rosario; Izaskun, Bilbao
2008-05-01
The aim of this work is to show evidence of the validity of the Health-Related Quality of Life for Drug Abusers Test (HRQoLDA Test). This test was developed to measure specific HRQoL for drugs abusers, within the theoretical addiction framework of the biaxial model. The sample comprised 138 patients diagnosed with opiate drug dependence. In this study, the following constructs and variables of the biaxial model were measured: severity of dependence, physical health status, psychological adjustment and substance consumption. Results indicate that the HRQoLDA Test scores are related to dependency and consumption-related problems. Multiple regression analysis reveals that HRQoL can be predicted from drug dependence, physical health status and psychological adjustment. These results contribute empirical evidence of the theoretical relationships established between HRQoL and the biaxial model, and they support the interpretation of the HRQoLDA Test to measure HRQoL in drug abusers, thus providing a test to measure this specific construct in this population.
Haxel, Boris R; Huppertz, Tilman; Boessert, Patrick; Bast, Florian; Fruth, Kai
2016-01-01
Allergen-specific immunotherapy for house-dust mite (HDM) allergies is associated with lower success rates when compared with similar treatments for other inhalant allergens, such as grass or birch. One reason might be the greater difficulty in diagnosing patients with assumed HDM allergies because symptoms occur perennially and may differ from those of a conventional allergic rhinitis. The aim of the study was to compare the different methods of diagnosis in patients with assumed HDM allergy. We performed a retrospective analysis of nasal provocation tests (NPT) from patients (n = 161) evaluated for Dermatophagoides pteronyssinus (n = 127) and Dermatophagoides farinae (n = 104) allergies, and compared the results with other allergen testing methods (skin-prick test [SPT], intracutaneous test, and allergen specific immunoglobulin E levels [sIgE] to detect sensitization). Receiver operating characteristic curves were used for the analyses and the areas under the curve were calculated. For D. pteronyssinus and D. farinae, 86 and 70 complete data files, respectively, were available. For both tested HDMs, the results of the receiver operating characteristic curves showed a significant correlation for SPT and sIgE, with the results of the NPT (area under the curve, 0.742 to 0.763) but not for the intracutaneous test. In patients with a positive SPT (≥3 mm), an allergy was confirmed by the NPT in 69% of cases for D. pteronyssinus and 71% for D. farinae. A positive sIgE result (ImmunoCAP class of ≥2) was verified by the NPT in 69% of cases (D. pteronyssinus) and 70% (D. farinae). The predictability value for a positive NPT result is best for SPT and sIgE. Nevertheless, even if the results of both test systems are combined, the positive predictive value that was achieved was only 0.77 for D. pteronyssinus and 0.69 for D. farinae. Therefore, in patients eligible for immunotherapy for HDM, an NPT should be performed before the start of the therapy to verify a clinically relevant allergy.
Jindal, Shveta; Dada, Tanuj; Sreenivas, V; Gupta, Viney; Sihota, Ramanjit; Panda, Anita
2010-01-01
Purpose: To compare the diagnostic performance of the Heidelberg retinal tomograph (HRT) glaucoma probability score (GPS) with that of Moorfield’s regression analysis (MRA). Materials and Methods: The study included 50 eyes of normal subjects and 50 eyes of subjects with early-to-moderate primary open angle glaucoma. Images were obtained by using HRT version 3.0. Results: The agreement coefficient (weighted k) for the overall MRA and GPS classification was 0.216 (95% CI: 0.119 – 0.315). The sensitivity and specificity were evaluated using the most specific (borderline results included as test negatives) and least specific criteria (borderline results included as test positives). The MRA sensitivity and specificity were 30.61 and 98% (most specific) and 57.14 and 98% (least specific). The GPS sensitivity and specificity were 81.63 and 73.47% (most specific) and 95.92 and 34.69% (least specific). The MRA gave a higher positive likelihood ratio (28.57 vs. 3.08) and the GPS gave a higher negative likelihood ratio (0.25 vs. 0.44).The sensitivity increased with increasing disc size for both MRA and GPS. Conclusions: There was a poor agreement between the overall MRA and GPS classifications. GPS tended to have higher sensitivities, lower specificities, and lower likelihood ratios than the MRA. The disc size should be taken into consideration when interpreting the results of HRT, as both the GPS and MRA showed decreased sensitivity for smaller discs and the GPS showed decreased specificity for larger discs. PMID:20952832
NASA Technical Reports Server (NTRS)
Mason, M. G.
1975-01-01
A simulator is described, which was designed for testing and evaluating inertial measuring units, and flight platforms. Mechanical and electrical specifications for the outer, middle, and inner axis are presented. Test results are included.
Is case-specificity content-specificity? An analysis of data from extended-matching questions.
Dory, Valerie; Gagnon, Robert; Charlin, Bernard
2010-03-01
Case-specificity, i.e., variability of a subject's performance across cases, has been a consistent finding in medical education. It has important implications for assessment validity and reliability. Its root causes remain a matter of discussion. One hypothesis, content-specificity, links variability of performance to variable levels of relevant knowledge. Extended-matching items (EMIs) are an ideal format to test this hypothesis as items are grouped by topic. If differences pertaining to content knowledge are the main cause of case-specificity, variability across topics should be high and variability across items within the same topic low. We used generalisability analysis on results of a written test composed of 159 EMIs sat by two cohorts of general practice trainees at one university. Two hundred and twenty-seven trainees took part. The variance component attributed to subjects was small. Variance attributed to topics was smaller than variance attributed to items. The main source of error was interaction between subjects and items, accounting for two-thirds of error. The generalisability D study revealed that for the same total number of items, increasing the number of topics results in a higher G coefficient than increasing the number of items per topic. Topical knowledge does not seem to explain case-specificity observed in our data. Structure of knowledge and reasoning strategy may be more important, in particular pattern-recognition which EMIs were designed to elicit. The causal explanations of case-specificity may be dependent on test format. Increasing the number of topics with fewer items each would increase reliability but also testing time.
An Investigation of the Learning Strategies as Bias Factors in Second Language Cloze Tests
ERIC Educational Resources Information Center
Ajideh, Parviz; Yaghoubi-Notash, Massoud; Khalili, Abdolreza
2017-01-01
The present study investigated the contribution of the EFL students' learning strategies to the explanation of the variance in their results on language tests. More specifically, it examined the role of these strategies as bias factors in the results of English cloze tests. Based on this aim, first, 158 intermediate EFL learners were selected from…
Evaluation of serological tests for diagnosis of Brucella melitensis infection of goats.
Díaz-Aparicio, E; Marín, C; Alonso-Urmeneta, B; Aragón, V; Pérez-Ortiz, S; Pardo, M; Blasco, J M; Díaz, R; Moriyón, I
1994-01-01
Five serological assays were evaluated for the diagnosis of brucellosis in goats: the rose bengal test (RBT), complement fixation test (CFT), radial immunodiffusion (RID) with Brucella and Yersinia enterocolitica O:9 polysaccharides, counterimmunoelectrophoresis (CIEP) with cytosol, and enzyme-linked immunosorbent assay (ELISA) with polyclonal and protein G conjugates and smooth lipopolysaccharide (S-LPS), native hapten polysaccharide (NH), or cytosol antigens. For optimal sensitivity, RBT had to be used with sera-antigen at a 3:1 dilution. In the RID test, Brucella melitensis biotype 1 NH could not be replaced by Brucella abortus biotype 1 or Y. enterocolitica 0:9 polysaccharides. In the ELISA, S-LPS and NH gave similar results and the protein G conjugate increased the specificity. With the sera from 55 B. melitensis culture-positive goats, the sensitivity was 100% for RBT, CFT (titer > or = 4), and ELISA with S-LPS or NH; 94% for RID; and 93% for CIEP. All tests were negative (100% specific) when testing the sera from 127 brucella-free goats. Larger discrepancies among the results of the serological tests were obtained with sera from goats of areas where brucellosis is endemic. When the sera of 20 young goats vaccinated subcutaneously (10(9) CFU of B. melitensis Rev 1) and bled 6 months later were examined, the specificities were as follows: NH ELISA, 60%; CFT and S-LPS ELISA, 75%; RBT, 80%; CIEP, 90%; and RID, 94%. With the sera from 10 young goats vaccinated conjunctivally (10(9) CFU of B. melitensis Rev 1) all tests were 100% specific 4 months after vaccination. The proportion of goats giving a positive reaction after vaccination decreased faster in RID than in other tests. PMID:8051240
Critical evaluation of a badminton-specific endurance test.
Fuchs, Michael; Faude, Oliver; Wegmann, Melissa; Meyer, Tim
2014-03-01
To overcome the limitations of traditional 1-dimensional fitness tests in analyzing physiological properties of badminton players, a badminton-specific endurance test (BST) was created. This study aimed at analyzing the influence of various fitness dimensions on BST performance. 18 internationally competing male German badminton players (22.4 ± 3.2 y, 79.2 ± 7.7 kg, 1.84 ± 0.06 m, world-ranking position [WRP] 21-501) completed a straight-sprint test, a change-of-direction speed test, various jump tests (countermovement jump, drop jump, standing long jump), a multistage running test (MST), and the BST. During this on-court field test players have to respond to a computerized sign indicating direction and speed of badminton-specific movements by moving into the corresponding corners. Significant correlations were found between performance in MST and BST (individual anaerobic threshold [IAT], r = .63, P = .005; maximum velocity [Vmax], r = .60, P = .009). A negative correlation (r = -.59, P = .014) was observed between IAT in BST and drop-jump contact time. No further associations between performance indices could be detected. Apart from a small portion explained by MST results (IAT, R2 = .40; Vmax, R2 = .36), the majority of BST performance cannot be explained by the determined physiological correlates. Moreover, it was impossible to predict the WRP of a player on the basis of BST results (r = -.15, P = .55). Neither discipline-specific performance nor basic physiological properties were appropriately reflected by a BST in elite badminton players. This does not substantiate its validity for regular use as a testing tool. However, it may be useful for monitoring on-court training sessions.
Kosack, Cara S.; Shanks, Leslie; Beelaert, Greet; Benson, Tumwesigye; Savane, Aboubacar; Ng'ang'a, Anne; Bita, André; Zahinda, Jean-Paul B. N.; Fransen, Katrien
2017-01-01
ABSTRACT Our objective was to evaluate the performance of HIV testing algorithms based on WHO recommendations, using data from specimens collected at six HIV testing and counseling sites in sub-Saharan Africa (Conakry, Guinea; Kitgum and Arua, Uganda; Homa Bay, Kenya; Douala, Cameroon; Baraka, Democratic Republic of Congo). A total of 2,780 samples, including 1,306 HIV-positive samples, were included in the analysis. HIV testing algorithms were designed using Determine as a first test. Second and third rapid diagnostic tests (RDTs) were selected based on site-specific performance, adhering where possible to the WHO-recommended minimum requirements of ≥99% sensitivity and specificity. The threshold for specificity was reduced to 98% or 96% if necessary. We also simulated algorithms consisting of one RDT followed by a simple confirmatory assay. The positive predictive values (PPV) of the simulated algorithms ranged from 75.8% to 100% using strategies recommended for high-prevalence settings, 98.7% to 100% using strategies recommended for low-prevalence settings, and 98.1% to 100% using a rapid test followed by a simple confirmatory assay. Although we were able to design algorithms that met the recommended PPV of ≥99% in five of six sites using the applicable high-prevalence strategy, options were often very limited due to suboptimal performance of individual RDTs and to shared falsely reactive results. These results underscore the impact of the sequence of HIV tests and of shared false-reactivity data on algorithm performance. Where it is not possible to identify tests that meet WHO-recommended specifications, the low-prevalence strategy may be more suitable. PMID:28747371
Discordance between Aeroallergen Specific Serum IgE and Skin Testing in Children < 4 years of age
de Vos, Gabriele; Nazari, Ramin; Ferastraoaru, Denisa; Parikh, Purvi; Geliebter, Rebecca; Pichardo, Yikania; Wiznia, Andrew; Rosenstreich, David
2015-01-01
Background Atopic sensitization to aeroallergens in early life has been shown to be a strong risk factor for developing persisting asthma in young children with recurrent wheeze. Objective The aim of this study was to assess the yield of skin prick test (SPT) compared to allergen specific serum IgE testing (sIgE) at identifying aeroallergen sensitization in atopic children < 4 years of age. Methods Concordance between SPT (Greer Laboratories, ComforTen™) and allergen specific sIgE (Immulite 2000™) for 7 common aeroallergens was analyzed in forty atopic inner-city children, 18–48 months of age (mean 36 +/− 9 months) with recurrent wheezing, family history of asthma and/or eczema. Results In 80% of children one or more allergen sensitizations would have been missed if only SPT had been performed, and in 38% of children one or more sensitizations would have been missed if only serum IgE testing had been performed. Agreement and between SPT and sIgE test was fair for most allergens (kappa between −0.04 and 0.50), as was correlation between sIgE levels and SPT grade (rho between 0.21 and 0.55). Children with high total sIgE (≥300 kU/l) were more likely to have sIgE positive tests with negative corresponding skin test (p=0.025). Conclusions Our study showed significant discordance between allergen specific SPT and sIgE testing results for common aeroallergens, suggesting that both SPT and sIgE testing should be done when diagnosing allergic sensitization in young children at high risk of asthma. PMID:23706713
Behavioral and fMRI evidence of the differing cognitive load of domain-specific assessments.
Howard, S J; Burianová, H; Ehrich, J; Kervin, L; Calleia, A; Barkus, E; Carmody, J; Humphry, S
2015-06-25
Standards-referenced educational reform has increased the prevalence of standardized testing; however, whether these tests accurately measure students' competencies has been questioned. This may be due to domain-specific assessments placing a differing domain-general cognitive load on test-takers. To investigate this possibility, functional magnetic resonance imaging (fMRI) was used to identify and quantify the neural correlates of performance on current, international standardized methods of spelling assessment. Out-of-scanner testing was used to further examine differences in assessment results. Results provide converging evidence that: (a) the spelling assessments differed in the cognitive load placed on test-takers; (b) performance decreased with increasing cognitive load of the assessment; and (c) brain regions associated with working memory were more highly activated during performance of assessments that were higher in cognitive load. These findings suggest that assessment design should optimize the cognitive load placed on test-takers, to ensure students' results are an accurate reflection of their true levels of competency. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Analytical control test plan and microbiological methods for the water recovery test
NASA Technical Reports Server (NTRS)
Traweek, M. S. (Editor); Tatara, J. D. (Editor)
1994-01-01
Qualitative and quantitative laboratory results are important to the decision-making process. In some cases, they may represent the only basis for deciding between two or more given options or processes. Therefore, it is essential that handling of laboratory samples and analytical operations employed are performed at a deliberate level of conscientious effort. Reporting erroneous results can lead to faulty interpretations and result in misinformed decisions. This document provides analytical control specifications which will govern future test procedures related to all Water Recovery Test (WRT) Phase 3 activities to be conducted at the National Aeronautics and Space Administration/Marshall Space Flight Center (NASA/MSFC). This document addresses the process which will be used to verify analytical data generated throughout the test period, and to identify responsibilities of key personnel and participating laboratories, the chains of communication to be followed, and ensure that approved methodology and procedures are used during WRT activities. This document does not outline specifics, but provides a minimum guideline by which sampling protocols, analysis methodologies, test site operations, and laboratory operations should be developed.
Achievement Test Provincial Report, June 1987 Administration.
ERIC Educational Resources Information Center
Alberta Dept. of Education, Edmonton. Student Evaluation and Records Branch.
This document summarizes results of province-wide achievement tests given in Alberta, Canada in June 1987. These tests evaluated student achievement in third grade science, sixth grade mathematics, and ninth grade social studies. The test questions for each subject area reflected Alberta's curriculum specifications for that subject. The grade 3…
Sesame allergy: role of specific IgE and skin-prick testing in predicting food challenge results.
Permaul, Perdita; Stutius, Lisa M; Sheehan, William J; Rangsithienchai, Pitud; Walter, Jolan E; Twarog, Frank J; Young, Michael C; Scott, Jordan E; Schneider, Lynda C; Phipatanakul, Wanda
2009-01-01
There are conflicting data regarding the diagnostic value of sesame-specific IgE and sesame skin test. Currently, there are no established thresholds that predict clinical reactivity. We examined the correlation of sesame ImmunoCAP and skin-prick test (SPT) results with oral challenge outcomes in children suspected of having a sesame food allergy. We conducted a retrospective chart review of children, aged 2-12 years, receiving a sesame ImmunoCAP level, SPT, and food challenge from January 2004 to August 2008 at Children's Hospital Boston and affiliated allergy clinics. Food challenges were conducted in cases of questionable clinical history or a negative ImmunoCAP and/or negative SPT despite a convincing history. Thirty-three oral sesame challenges were conducted. Of the 33 challenges performed, 21% (n = 7) failed and 79% (n = 26) passed. A sesame-specific IgE level of > or = 7 kU(A)/L showed specificity of >90%. An SPT wheal size of > or = 6 mm showed specificity of >90%. Receiver operator characteristic (ROC) curve analysis for sesame-specific IgE revealed an area under the curve (AUC) of 0.56. ROC curve analysis for SPT wheal size revealed an AUC of 0.67. To our knowledge, this study represents the largest number of sesame challenges performed to evaluate the diagnostic value of both sesame-specific IgE and SPT. Based on our sample, both tests are not good predictors of true sesame allergy as determined by an oral challenge. We were unable to establish a threshold with a 95% positive predictive value for both sesame-specific IgE and SPT.
Specific Stimuli Induce Specific Adaptations: Sensorimotor Training vs. Reactive Balance Training
Freyler, Kathrin; Krause, Anne; Gollhofer, Albert; Ritzmann, Ramona
2016-01-01
Typically, balance training has been used as an intervention paradigm either as static or as reactive balance training. Possible differences in functional outcomes between the two modalities have not been profoundly studied. The objective of the study was to investigate the specificity of neuromuscular adaptations in response to two balance intervention modalities within test and intervention paradigms containing characteristics of both profiles: classical sensorimotor training (SMT) referring to a static ledger pivoting around the ankle joint vs. reactive balance training (RBT) using externally applied perturbations to deteriorate body equilibrium. Thirty-eight subjects were assigned to either SMT or RBT. Before and after four weeks of intervention training, postural sway and electromyographic activities of shank and thigh muscles were recorded and co-contraction indices (CCI) were calculated. We argue that specificity of training interventions could be transferred into corresponding test settings containing properties of SMT and RBT, respectively. The results revealed that i) postural sway was reduced in both intervention groups in all test paradigms; magnitude of changes and effect sizes differed dependent on the paradigm: when training and paradigm coincided most, effects were augmented (P<0.05). ii) These specificities were accompanied by segmental modulations in the amount of CCI, with a greater reduction within the CCI of thigh muscles after RBT compared to the shank muscles after SMT (P<0.05). The results clearly indicate the relationship between test and intervention specificity in balance performance. Hence, specific training modalities of postural control cause multi-segmental and context-specific adaptations, depending upon the characteristics of the trained postural strategy. In relation to fall prevention, perturbation training could serve as an extension to SMT to include the proximal segment, and thus the control of structures near to the body’s centre of mass, into training. PMID:27911944
Miller, Ezer; Huppert, Amit; Novikov, Ilya; Warburg, Alon; Hailu, Asrat; Abbasi, Ibrahim; Freedman, Laurence S
2015-11-10
In this work, we describe a two-stage sampling design to estimate the infection prevalence in a population. In the first stage, an imperfect diagnostic test was performed on a random sample of the population. In the second stage, a different imperfect test was performed in a stratified random sample of the first sample. To estimate infection prevalence, we assumed conditional independence between the diagnostic tests and develop method of moments estimators based on expectations of the proportions of people with positive and negative results on both tests that are functions of the tests' sensitivity, specificity, and the infection prevalence. A closed-form solution of the estimating equations was obtained assuming a specificity of 100% for both tests. We applied our method to estimate the infection prevalence of visceral leishmaniasis according to two quantitative polymerase chain reaction tests performed on blood samples taken from 4756 patients in northern Ethiopia. The sensitivities of the tests were also estimated, as well as the standard errors of all estimates, using a parametric bootstrap. We also examined the impact of departures from our assumptions of 100% specificity and conditional independence on the estimated prevalence. Copyright © 2015 John Wiley & Sons, Ltd.
ELISA versus PCR for diagnosis of chronic Chagas disease: systematic review and meta-analysis
2010-01-01
Background Most current guidelines recommend two serological tests to diagnose chronic Chagas disease. When serological tests are persistently inconclusive, some guidelines recommend molecular tests. The aim of this investigation was to review chronic Chagas disease diagnosis literature and to summarize results of ELISA and PCR performance. Methods A systematic review was conducted searching remote databases (MEDLINE, LILACS, EMBASE, SCOPUS and ISIWeb) and full texts bibliography for relevant abstracts. In addition, manufacturers of commercial tests were contacted. Original investigations were eligible if they estimated sensitivity and specificity, or reliability -or if their calculation was possible - of ELISA or PCR tests, for chronic Chagas disease. Results Heterogeneity was high within each test (ELISA and PCR) and threshold effect was detected only in a particular subgroup. Reference standard blinding partially explained heterogeneity in ELISA studies, and pooled sensitivity and specificity were 97.7% [96.7%-98.5%] and 96.3% [94.6%-97.6%] respectively. Commercial ELISA with recombinant antigens studied in phase three investigations partially explained heterogeneity, and pooled sensitivity and specificity were 99.3% [97.9%-99.9%] and 97.5% [88.5%-99.5%] respectively. ELISA's reliability was seldom studied but was considered acceptable. PCR heterogeneity was not explained, but a threshold effect was detected in three groups created by using guanidine and boiling the sample before DNA extraction. PCR sensitivity is likely to be between 50% and 90%, while its specificity is close to 100%. PCR reliability was never studied. Conclusions Both conventional and recombinant based ELISA give useful information, however there are commercial tests without technical reports and therefore were not included in this review. Physicians need to have access to technical reports to understand if these serological tests are similar to those included in this review and therefore correctly order and interpret test results. Currently, PCR should not be used in clinical practice for chronic Chagas disease diagnosis and there is no PCR test commercially available for this purpose. Tests limitations and directions for future research are discussed. PMID:21108793
Szabó, I; Scherer, K; Roesler, U; Appel, B; Nöckler, K; Hensel, A
2008-05-10
The most frequently isolated Salmonella serotype from pork in Germany is S. typhimurium, especially phagetype DT 104. The monitoring programs on Salmonella in swine are based on enzyme-linked immunoadsorbent assay (ELISA) detecting antibodies in serum or meat juice. These serological results are used to classify swine herds in three categories to assess the hygienic status of farm regarding Salmonella infection in pigs. The object of this study was the comparative evaluation of four indirect Salmonella ELISA tests approved in Germany to detect Salmonella typhimurium infection of swine. Three tests (A-C) are based on LPS-antigen and directed against specific IgG-antibodies. The fourth test (D) bases on a whole-cell-lysate antigen and discriminates between Salmonella specific IgA-, IgM- and IgG-antibodies. In a longitudinal study sixteen 6 weeks old weaning pigs were orally infected with S. typhimurium DT 104. During an observation period of 138d clinical and bacteriological parameters were monitored and serum samples obtained at regular intervals as well as meat juice samples taken at slaughter were examined by the respective ELISA systems. Study results reveal that all tested ELISA systems are able to detect S. typhimurium infection in pigs in both sample matrices, blood serum and meat juice whereas test D showed the highest sensitivity to detect Salmonella antibodies in pigs. The sensitivity to detect Salmonella antibodies varied between tests A and C according to the used cut-off (test specific cut-off vs. recommended surveillance cut-off) resulting in a change of seroprevalence and hence may influence the Salmonella status of the farm.
Wimpee, C F; Nadeau, T L; Nealson, K H
1991-01-01
By using two highly conserved region of the luxA gene as primers, polymerase chain reaction amplification methods were used to prepare species-specific probes against the luciferase gene from four major groups of marine luminous bacteria. Laboratory studies with test strains indicated that three of the four probes cross-reacted with themselves and with one or more of the other species at low stringencies but were specific for members of their own species at high stringencies. The fourth probe, generated from Vibrio harveyi DNA, cross-reacted with DNAs from two closely related species, V. orientalis and V. vulnificus. When nonluminous cultures were tested with the species-specific probes, no false-positive results were observed, even at low stringencies. Two field isolates were correctly identified as Photobacterium phosphoreum by using the species-specific hybridization probes at high stringency. A mixed probe (four different hybridization probes) used at low stringency gave positive results with all of the luminous bacteria tested, including the terrestrial species, Xenorhabdus luminescens, and the taxonomically distinct marine bacterial species Shewanella hanedai; minimal cross-hybridization with these species was seen at higher stringencies. Images PMID:1854194
... of prostate cancer. But, it can increase your prostate-specific antigen (PSA) blood test result. Symptoms With early prostate ... 2009 Best Practice Statement. www.auanet.org/guidelines/prostate-specific-antigen-(2009-amended-2013) . Accessed October 9, 2017. Moyer ...
Auditory Perceptual Abilities Are Associated with Specific Auditory Experience
Zaltz, Yael; Globerson, Eitan; Amir, Noam
2017-01-01
The extent to which auditory experience can shape general auditory perceptual abilities is still under constant debate. Some studies show that specific auditory expertise may have a general effect on auditory perceptual abilities, while others show a more limited influence, exhibited only in a relatively narrow range associated with the area of expertise. The current study addresses this issue by examining experience-dependent enhancement in perceptual abilities in the auditory domain. Three experiments were performed. In the first experiment, 12 pop and rock musicians and 15 non-musicians were tested in frequency discrimination (DLF), intensity discrimination, spectrum discrimination (DLS), and time discrimination (DLT). Results showed significant superiority of the musician group only for the DLF and DLT tasks, illuminating enhanced perceptual skills in the key features of pop music, in which miniscule changes in amplitude and spectrum are not critical to performance. The next two experiments attempted to differentiate between generalization and specificity in the influence of auditory experience, by comparing subgroups of specialists. First, seven guitar players and eight percussionists were tested in the DLF and DLT tasks that were found superior for musicians. Results showed superior abilities on the DLF task for guitar players, though no difference between the groups in DLT, demonstrating some dependency of auditory learning on the specific area of expertise. Subsequently, a third experiment was conducted, testing a possible influence of vowel density in native language on auditory perceptual abilities. Ten native speakers of German (a language characterized by a dense vowel system of 14 vowels), and 10 native speakers of Hebrew (characterized by a sparse vowel system of five vowels), were tested in a formant discrimination task. This is the linguistic equivalent of a DLS task. Results showed that German speakers had superior formant discrimination, demonstrating highly specific effects for auditory linguistic experience as well. Overall, results suggest that auditory superiority is associated with the specific auditory exposure. PMID:29238318
Latest trends in parts SEP susceptibility from heavy ions
NASA Technical Reports Server (NTRS)
Nichols, Donald K.; Smith, L. S.; Soli, George A.; Koga, R.; Kolasinski, W. A.
1989-01-01
JPL and Aerospace have collected a third set of heavy-ion single-event phenomena (SEP) test data since their last joint IEEE publications in December 1985 and December 1987. Trends in SEP susceptibility (e.g., soft errors and latchup) for state-of-the-art parts are presented. Results of the study indicate that hard technologies and unacceptably soft technologies can be flagged. In some instances, specific tested parts can be taken as candidates for key microprocessors or memories. As always with radiation test data, specific test data for qualified flight parts is recommended for critical applications.
Schmidt, Jana; Guder, Ulrike; Kreuz, Markus; Löffler, Markus; Kiess, Wieland; Hirsch, Christian; Ziebolz, Dirk; Haak, Rainer
2018-01-01
The suitability of a chairside aMMP-8 test in determination of periodontal inflammation and caries in adolescents was assessed. Secondly, the influence of orthodontic treatment on aMMP-8 test result was analyzed. Within the LIFE Child study, 434 adolescents (10 to 18 years) were included. Clinical dental examinations comprised caries experience (DMF/T-Index), signs of periodontal inflammation (probing pocket depth, PPD; community periodontal index of treatment needs; CPITN) at six index teeth and oral hygiene (OH). Information about orthodontic appliances (OA) and socioeconomic status (SES) were obtained by validated questionnaires. Test's sensitivity and specificity to detect periodontal inflammation and carious lesions were evaluated. The influence of OA on the test result was analyzed (multivariate model). No associations between age, gender, SES or OH, and test outcome were found (p > 0.05). Positive test results correlated to periodontal findings (CPITN, mean PPD; p < 0.001). However, for the detection of ≥ 1 site(s) with PPD ≥ 4 mm, the test's sensitivity and specificity were found to be 61 and 69%, respectively. Multivariate analysis revealed a higher probability for a positive test result in cases of fixed OA (odds ratio 5.02, 95% confidence interval 1.90-13.19). The test had no diagnostic value considering carious lesions. The chairside aMMP-8 test does not reliably identify adolescents with periodontal inflammation. Positive test results were more frequent in case of OA. The chairside aMMP-8 test is no appropriate tool to screen children and adolescents neither for periodontal inflammation nor for carious lesions.
Psychometric evaluation of commonly used game-specific skills tests in rugby: A systematic review
Oorschot, Sander; Chiwaridzo, Matthew; CM Smits-Engelsman, Bouwien
2017-01-01
Objectives To (1) give an overview of commonly used game-specific skills tests in rugby and (2) evaluate available psychometric information of these tests. Methods The databases PubMed, MEDLINE CINAHL and Africa Wide information were systematically searched for articles published between January 1995 and March 2017. First, commonly used game-specific skills tests were identified. Second, the available psychometrics of these tests were evaluated and the methodological quality of the studies assessed using the Consensus-based Standards for the selection of health Measurement Instruments checklist. Studies included in the first step had to report detailed information on the construct and testing procedure of at least one game-specific skill, and studies included in the second step had additionally to report at least one psychometric property evaluating reliability, validity or responsiveness. Results 287 articles were identified in the first step, of which 30 articles met the inclusion criteria and 64 articles were identified in the second step of which 10 articles were included. Reactive agility, tackling and simulated rugby games were the most commonly used tests. All 10 studies reporting psychometrics reported reliability outcomes, revealing mainly strong evidence. However, all studies scored poor or fair on methodological quality. Four studies reported validity outcomes in which mainly moderate evidence was indicated, but all articles had fair methodological quality. Conclusion Game-specific skills tests indicated mainly high reliability and validity evidence, but the studies lacked methodological quality. Reactive agility seems to be a promising domain, but the specific tests need further development. Future high methodological quality studies are required in order to develop valid and reliable test batteries for rugby talent identification. Trial registration number PROSPERO CRD42015029747. PMID:29259812
Weitzel, T; Schnabel, E; Dieckmann, S; Börner, U; Schweiger, B
2007-07-01
Point-of-care (POC) tests for influenza facilitate clinical case management, and might also be helpful in the care of travellers who are at special risk for influenza infection. To evaluate influenza POC testing in travellers, a new assay, the ImmunoCard STAT! Flu A and B, was used to investigate travellers presenting with influenza-like symptoms. Influenza virus infection was diagnosed in 27 (13%) of 203 patients by influenza virus-specific PCR and viral culture. The POC test had sensitivity and specificity values of 64% and 99% for influenza A, and 67% and 100% for influenza B, respectively. Combined sensitivity and specificity were 67% and 99%, respectively, yielding positive and negative predictive values of 95%, and positive and negative likelihood ratios of 117 and 0.34, respectively. The convenient application, excellent specificity and high positive likelihood ratio of the POC test allowed rapid identification of influenza cases. However, negative test results might require confirmation by other methods because of limitations in sensitivity. Overall, influenza POC testing appeared to be a useful tool for the management of travellers with influenza-like symptoms.
Code of Federal Regulations, 2013 CFR
2013-07-01
... II Equivalent Samplers Performance test Specifications Acceptance criteria § 53.62 Full Wind Tunnel... Results: 95% ≤ Rc ≤ 105%. § 53.63 Wind Tunnel Inlet Aspiration Test Liquid VOAG produced aerosol at 2 km... Class II Equivalent Samplers F Table F-1 to Subpart F of Part 53 Protection of Environment ENVIRONMENTAL...
Code of Federal Regulations, 2014 CFR
2014-07-01
... II Equivalent Samplers Performance test Specifications Acceptance criteria § 53.62 Full Wind Tunnel... Results: 95% ≤Rc ≤105%. § 53.63 Wind Tunnel Inlet Aspiration Test Liquid VOAG produced aerosol at 2 km/hr... Class II Equivalent Samplers F Table F-1 to Subpart F of Part 53 Protection of Environment ENVIRONMENTAL...
Kang, Leni; Zhang, Shaokai; Zhao, Fanghui; Qiao, Youlin
2014-03-01
To evaluate and adjust the verification bias existed in the screening or diagnostic tests. Inverse-probability weighting method was used to adjust the sensitivity and specificity of the diagnostic tests, with an example of cervical cancer screening used to introduce the Compare Tests package in R software which could be implemented. Sensitivity and specificity calculated from the traditional method and maximum likelihood estimation method were compared to the results from Inverse-probability weighting method in the random-sampled example. The true sensitivity and specificity of the HPV self-sampling test were 83.53% (95%CI:74.23-89.93)and 85.86% (95%CI: 84.23-87.36). In the analysis of data with randomly missing verification by gold standard, the sensitivity and specificity calculated by traditional method were 90.48% (95%CI:80.74-95.56)and 71.96% (95%CI:68.71-75.00), respectively. The adjusted sensitivity and specificity under the use of Inverse-probability weighting method were 82.25% (95% CI:63.11-92.62) and 85.80% (95% CI: 85.09-86.47), respectively, whereas they were 80.13% (95%CI:66.81-93.46)and 85.80% (95%CI: 84.20-87.41) under the maximum likelihood estimation method. The inverse-probability weighting method could effectively adjust the sensitivity and specificity of a diagnostic test when verification bias existed, especially when complex sampling appeared.
Capturing specific abilities as a window into human individuality: The example of face recognition
Wilmer, Jeremy B.; Germine, Laura; Chabris, Christopher F.; Chatterjee, Garga; Gerbasi, Margaret; Nakayama, Ken
2013-01-01
Proper characterization of each individual's unique pattern of strengths and weaknesses requires good measures of diverse abilities. Here, we advocate combining our growing understanding of neural and cognitive mechanisms with modern psychometric methods in a renewed effort to capture human individuality through a consideration of specific abilities. We articulate five criteria for the isolation and measurement of specific abilities, then apply these criteria to face recognition. We cleanly dissociate face recognition from more general visual and verbal recognition. This dissociation stretches across ability as well as disability, suggesting that specific developmental face recognition deficits are a special case of a broader specificity that spans the entire spectrum of human face recognition performance. Item-by-item results from 1,471 web-tested participants, included as supplementary information, fuel item analyses, validation, norming, and item response theory (IRT) analyses of our three tests: (a) the widely used Cambridge Face Memory Test (CFMT); (b) an Abstract Art Memory Test (AAMT), and (c) a Verbal Paired-Associates Memory Test (VPMT). The availability of this data set provides a solid foundation for interpreting future scores on these tests. We argue that the allied fields of experimental psychology, cognitive neuroscience, and vision science could fuel the discovery of additional specific abilities to add to face recognition, thereby providing new perspectives on human individuality. PMID:23428079
Meier, Beat; Rothen, Nicolas
2009-03-01
The goal of this study was to investigate whether behavioural and physiological consequences of synaesthesia can be elicited by training specific letter-colour associations. Towards this goal 20 non-synaesthetic individuals were trained for 10 min on 7 consecutive days to associate four different letters with four specific colours. After training, we administered the synaesthetic Stroop test and the synaesthetic conditioning test. The results showed that a 1-week letter-colour association-training was sufficient to elicit a synaesthetic Stroop effect. In contrast, there was no evidence for a conditioned synaesthetic response as measured by skin conductance response in the synaesthetic conditioning test. These results indicate that the presence of a synaesthetic Stroop effect is not unique to true synaesthetes. We discuss methodological, experiential, and neuronal reasons for the dissociation between the synaesthetic Stroop test and the synaesthetic conditioning test.
Results of Long Term Life Tests of Large Scale Lithium-Ion Cells
NASA Astrophysics Data System (ADS)
Inoue, Takefumi; Imamura, Nobutaka; Miyanaga, Naozumi; Yoshida, Hiroaki; Komada, Kanemi
2008-09-01
High energy density Li-ion cells have been introduced to latest satellites and another space usage. We have started development of large scale Li-ion cells for space applications in 1997. The chemical design was fixed in 1999.It is very important to confirm life performance to apply satellite applications because it requires long mission life such as 15 years for GEO and 5 to 7 years for LEO. Therefore we started life test at various conditions. And the tests have reached 8 to 9 years in actual calendar time. Semi - accelerated GEO tests which gives both calendar and cycle loss have been reached 42 season that corresponds 21 years in orbit. The specific energy range is 120 - 130 Wh/kg at EOL. According to the test results, we have confirmed that our Li-ion cell meets general requirements for space application such as GEO and LEO with quite high specific energy.
Disability and Preventive Cancer Screening: Results from the 2001 California Health Interview Survey
Ramirez, Anthony; Farmer, Gail C.; Grant, David; Papachristou, Theodora
2005-01-01
Objective. We sought to evaluate preventive cancer screening compliance among adults with disability in California. Methods. We used data from the 2001 California Health Interview Survey to compare disabled and nondisabled adults for differences in preventive cancer screening behaviors. Compliance rates for cancer screening tests (mammography, Papanicolaou test, prostate-specific antigen, sigmoidoscopy/colonoscopy, and fecal occult blood test) between the 2 subpopulations were evaluated. Results. Women with disabilities were 17% (Papanicolaou tests) and 13% (mammograms) more likely than women without disabilities to report noncompliance with cancer screening guidelines. Interactions between disability and reports of a doctor recommendation on cervical cancer screening were significant; women with disabilities had a lower likelihood of receiving a recommendation. Men with disabilities were 19% less likely than men without disabilities to report a prostate-specific antigen test within the last 3 years. Conclusions.secondary to structural and/or clinical factors underpinning the differences found. PMID:16195509
Performance of Charcoal Cookstoves for Haiti, Part 2: Results from the Controlled Cooking Test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lask, Kathleen; Jones, Jennifer; Booker, Kayje
2011-11-30
Five charcoal cookstoves were tested using a Controlled Cooking Test (CCT) developed from cooking practices in Haiti. Cookstoves were tested for total burn time, specific fuel consumption, and emissions of carbon monoxide (CO), carbon dioxide (CO 2), and the ratio of carbon monoxide to carbon dioxide (CO/CO 2). These results are presented in this report along with LBNL testers’ observations regarding the usability of the stoves.
ERIC Educational Resources Information Center
Lonchamp, F.
This is a presentation of the results of a factor analysis of a battery of tests intended to measure listening and reading comprehension in English as a second language. The analysis sought to answer the following questions: (1) whether the factor analysis method yields results when applied to tests which are not specifically designed for this…
Young, Grace J; Harrison, Sean; Turner, Emma L; Walsh, Eleanor I; Oliver, Steven E; Ben-Shlomo, Yoav; Evans, Simon; Lane, J Athene; Neal, David E; Hamdy, Freddie C; Donovan, Jenny L; Martin, Richard M; Metcalfe, Chris
2017-01-01
Objectives Cross-sectional studies suggest that around 6% of men undergo prostate-specific antigen (PSA) testing each year in UK general practice (GP). This longitudinal study aims to determine the cumulative testing pattern of men over a 10-year period and whether this testing can be considered equivalent to screening for prostate cancer (PCa). Setting, participants and outcome measures Patient-level data on PSA tests, biopsies and PCa diagnoses were obtained from the UK Clinical Practice Research Datalink (CPRD) for the years 2002 to 2011. The cumulative risks of PSA testing and of being diagnosed with PCa were estimated for the 10-year study period. Associations of a man’s age, region and index of multiple deprivation with the cumulative risk of PSA testing and PCa diagnosis were investigated. Rates of biopsy and diagnosis, following a high test result, were compared with those from the programme of PSA testing in the Prostate Testing for Cancer and Treatment (ProtecT) study. Results The 10-year risk of exposure to at least one PSA test in men aged 45 to 69 years in UK GP was 39.2% (95% CI 39.0 to 39.4%). The age-specific risks ranged from 25.2% for men aged 45–49 years to 53.0% for men aged 65–69 years (p for trend <0.001). For those with a PSA level ≥3, a test in UK GP was less likely to result in a biopsy (6%) and/or diagnosis of PCa (15%) compared with ProtecT study participants (85% and 34%, respectively). Conclusion A high proportion of men aged 45–69 years undergo PSA tests in UK GP: 39% over a 10-year period. A high proportion of these tests appear to be for the investigation of lower urinary tract symptoms and not screening for PCa. Trial registration number ISRCTN20141297, NCT02044172. PMID:29084797
Baars, Rolanda M; Atherton, Clare I; Koopman, Hendrik M; Bullinger, Monika; Power, Mick
2005-01-01
Background The European DISABKIDS project aims to enhance the Health Related Quality of Life (HRQoL) of children and adolescents with chronic medical conditions and their families. We describe the development of the seven cross-nationally tested condition-specific modules of the European DISABKIDS HRQoL instrument in a population of children and adolescents. The condition-specific modules are intended for use in conjunction with the DISABKIDS chronic generic module. Methods Focus groups were used to construct the pilot version of the DISABKIDS condition-specific HRQoL modules for asthma, juvenile idiopathic arthritis, atopic dermatitis, cerebral palsy, cystic fibrosis, diabetes and epilepsy. Analyses were conducted on pilot test data in order to construct field test versions of the modules. A series of factor analyses were run, first, to determine potential structures for each condition-specific module, and, secondly, to select a reduced number of items from the pilot test to be included in the field test. Post-field test analyses were conducted to retest the domain structure for the final DISABKIDS condition-specific modules. Results The DISABKIDS condition-specific modules were tested in a pilot study of 360 respondents, and subsequently in a field test of 1152 respondents in 7 European countries. The final condition-specific modules consist of an 'Impact' domain and an additional domain (e.g. worry, stigma, treatment) with between 10 to 12 items in total. The Cronbach's alpha of the final domains was found to vary from 0.71 to 0.90. Conclusion The condition-specific modules of the DISABKIDS instrument were developed through a step-by-step process including cognitive interview, clinical expertise, factor analysis, correlations and internal consistency. A cross-national pilot and field test were necessary to collect these data. In general, the internal consistency of the domains was satisfactory to high. In future, the DISABKIDS instrument may serve as a useful tool with which to assess HRQoL in children and adolescents with a chronic condition. The condition-specific modules can be used in conjunction with the DISABKIDS chronic generic module. PMID:16283947
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richmann, D.L.; Luke, K.W.; Terry, J.C.
1984-07-01
The results of a study to determine the relative grindability of US limestones and to relate grindability to petrographic properties are presented in this report. A laboratory ball mill test was developed to provide a quick and simple measure of grindability. These values were then used to explore possible correlations between grindability and the chemical and physical properties of the limestones. Chemical analyses and thin section petrographic analyses were used to characterize the limestone samples. The results of the laboratory ball mill test were compared to the results of an industrial grinding test, the Bond Work Index, for six samplesmore » which covered the grindability range. The two tests compared well with a correlation coefficient greater than 0.9. While the laboratory test is not sufficient to provide ball mill design specifications, it can be used as a screening and quality control test. The grinding results, expressed as a grindability index, ranged in values from 2 to 15. This represents a seven-fold range in the relative difficulties to grind for the limestones tested. From the petrographic analysis results, a strong correlation was found between the grindability and the fraction of macrocrystalline (> 5 ..mu..m) carbonate minerals present in the limestone. However, based on the high degree of variability characteristic of most limestone deposits, petrographic information should, in general, only be used to qualitatively predict the grindability of a specific limestone. An actual grinding test is recommended for a quantitative evaluation.« less
Flores-Ibarra, Alberto Alejandro; Ochoa-Vázquez, María Dolores; Sánchez-Tec, Georgina Alejandra
2016-01-01
In order to diagnose TB infection, tuberculin skin test and interferon gamma release assay are available. The tuberculin test has a sensitivity of 99 % and a specificity of 95 %. For the detection of interferon gamma in blood there are currently two tests available: TBGold QuantiFERON-In-Tube (with a sensitivity of 0.70 and a specificity of 0.90), and T-SPOT-TB (sensitivity 0.90 and specificity 0.93). To diagnose the disease, a microscopy of direct smears for acid-fast bacilli is used if the physician is facing an extensive cavitary lung disease due to M. tuberculosis (this test has a high sensitivity: 80-90 %). The most common staining techniques used are Ziehl-Neelsen and Kinyoun, and the fluorescent technique, auramine-rhodamine. The culture is the gold standard and it has a sensitivity of 80 % and a specificity over 90 %, but the results take weeks. The nucleic acid amplification test has an overall sensitivity and specificity of 0.85 and 0.97, respectively. In the presence of a pleural effusion is necessary to perform a pleural biopsy for culture with a sensitivity of 85 % if it is percutaneous and 98 % if it was taken by thoracoscopy. The adenosine deaminase can be determined in pleural fluid with a sensitivity and specificity of 95 %.
Does simultaneous bilingualism aggravate children's specific language problems?
Korkman, Marit; Stenroos, Maria; Mickos, Annika; Westman, Martin; Ekholm, Pia; Byring, Roger
2012-09-01
There is little data on whether or not a bilingual upbringing may aggravate specific language problems in children. This study analysed whether there was an interaction of such problems and simultaneous bilingualism. Participants were 5- to 7-year-old children with specific language problems (LANG group, N = 56) or who were typically developing (CONTR group, N = 60). Seventy-three children were Swedish-Finnish bilingual and 43 were Swedish-speaking monolingual. Assessments (in Swedish) included tests of expressive language, comprehension, repetition and verbal memory. Per definition, the LANG group had lower scores than the CONTR group on all language tests. The bilingual group had lower scores than the monolingual group only on a test of body part naming. Importantly, the interaction of group (LANG or CONTR) and bilingualism was not significant on any of the language scores. Simultaneous bilingualism does not aggravate specific language problems but may result in a slower development of vocabulary both in children with and without specific language problems. Considering also advantages, a bilingual upbringing is an option also for children with specific language problems. In assessment, tests of vocabulary may be sensitive to bilingualism, instead tests assessing comprehension, syntax and nonword repetition may provide less biased methods. © 2012 The Author(s)/Acta Paediatrica © 2012 Foundation Acta Paediatrica.
Carnley, Mark V.
2016-09-30
The Design Analysis Associates (DAA) DAA H-3613i radar water-level sensor (DAA H-3613i), manufactured by Xylem Incorporated, was evaluated by the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) for conformance to manufacturer’s accuracy specifications for measuring a distance throughout the sensor’s operating temperature range, for measuring distances from 3 to 15 feet at ambient temperatures, and for compliance with the SDI-12 serial-to-digital interface at 1200-baud communication standard. The DAA H-3613i is a noncontact water-level sensor that uses pulsed radar to measure the distance between the radar and the water surface from 0.75 to 131 feet over a temperature range of −40 to 60 degrees Celsius (°C). Manufacturer accuracy specifications that were evaluated, the test procedures that followed, and the results obtained are described in this report. The sensor’s accuracy specification of ± 0.01 feet (± 3 millimeters) meets USGS requirements for a primary water-stage sensor used in the operation of a streamgage. The sensor met the manufacturer’s stated accuracy specifications for water-level measurements during temperature testing at a distance of 8 feet from the target over its temperature-compensated operating range of −40 to 60 °C, except at 60 °C. At 60 °C, about half the measurements exceeded the manufacturer’s accuracy specification by not more than 0.005 feet.The sensor met the manufacturer’s stated accuracy specifications for water-level measurements during distance-accuracy testing at the tested distances from 3 to 15 feet above the water surface at the HIF.
Optical tests for using smartphones inside medical devices
NASA Astrophysics Data System (ADS)
Bernat, Amir S.; Acobas, Jennifer K.; Phang, Ye Shang; Hassan, David; Bolton, Frank J.; Levitz, David
2018-02-01
Smartphones are currently used in many medical applications and are more frequently being integrated into medical imaging devices. The regulatory requirements in existence today however, particularly the standardization of smartphone imaging through validation and verification testing, only partially cover imaging characteristics with a smartphone. Specifically, it has been shown that smartphone camera specifications are of sufficient quality for medical imaging, and there are devices which comply with the FDA's regulatory requirements for a medical device such as a device's field of view, direction of viewing and optical resolution and optical distortion. However, these regulatory requirements do not call specifically for color testing. Images of the same object using automatic settings or different light sources can show different color composition. Experimental results showing such differences are presented. Under some circumstances, such differences in color composition could potentially lead to incorrect diagnoses. It is therefore critical to control the smartphone camera and illumination parameters properly. This paper examines different smartphone camera settings that affect image quality and color composition. To test and select the correct settings, a test methodology is proposed. It aims at evaluating and testing image color correctness and white balance settings for mobile phones and LED light sources. Emphasis is placed on color consistency and deviation from gray values, specifically by evaluating the ΔC values based on the CIEL*a*b* color space. Results show that such standardization minimizes differences in color composition and thus could reduce the risk of a wrong diagnosis.
Hechemy, K E; Stevens, R W; Sasowski, S; Michaelson, E E; Casper, E A; Philip, R N
1979-01-01
Only 4.2% of 284 single specimens and 17.6% of 51 pairs of sera reactive in Weil-Felix agglutination tests for Rocky Mountain spotted fever were confirmed by a specific Rickettsia rickettsii microimmunofluorescence test. PMID:107194
ERIC Educational Resources Information Center
Pierangelo, Roger; Giuliani, George
This manual is a guide to the special education diagnostic process and covers the various stages of evaluation, interpretation, diagnosis, prescription, and remediation. Test information includes: explanations of the most commonly used diagnostic tests, coverage of the areas measured by each test, interpretation of test patterns for commonly used…
2011-01-01
Background Hepatitis C virus (HCV) is mainly transmitted by exposure to infected blood, and can lead to liver cirrhosis and liver cancer. Since the onset of HCV and the development of liver cirrhosis usually are asymptomatic, many HCV-infected individuals are still undiagnosed. To identify individuals infected with HCV in the general population, a low threshold, internet-mediated blood testing service was set up. We performed a qualitative study examining reasons for compliance and noncompliance with advice to test for HCV via the online blood testing service. Methods Semistructured telephone interviews were conducted with 33 website visitors who had been advised to test for HCV (18 testers, 15 non-testers). Transcribed interviews were analyzed qualitatively and interpreted using psychosocial theories of health behavior. Results Reasons for testing pertaining to the online service were: the testing procedure is autonomous, personalized test advice is provided online, reminder emails are sent, and there is an online planning tool. Reasons for testing not specific to the online service were: knowing one's status can prevent liver disease and further transmission of HCV, HCV is curable, testing can provide reassurance, physical complaints are present, and there is liver disease in one's social environment. Service-related reasons for not testing pertained to inconvenient testing facilities, a lack of commitment due to the low threshold character of the service, computer/printing problems, and incorrectly interpreting an online planning tool. The reasons for not testing that are not specific to the online service were: the belief that personal risk is low, the absence of symptoms, low perceived urgency for testing and treatment, fear of the consequences of a positive test result, avoiding threatening information, and a discouraging social environment. Conclusions Features specific to the online service played a significant role in motivation to test for HCV above and beyond the more conventional perceived health benefits of HCV testing. However, some online specific features were considered problematic and need to be adapted. Methods and strategies for dealing with these impeding factors and for improving compliance with testing via the online service are outlined. PMID:21569224
Urine and oral fluid drug testing in support of pain management.
Kwong, Tai C; Magnani, Barbarajean; Moore, Christine
2017-09-01
In recent years, the abuse of opioid drugs has resulted in greater prevalence of addiction, overdose, and deaths attributable to opioid abuse. The epidemic of opioid abuse has prompted professional and government agencies to issue practice guidelines for prescribing opioids to manage chronic pain. An important tool available to providers is the drug test for use in the initial assessment of patients for possible opioid therapy, subsequent monitoring of compliance, and documentation of suspected aberrant drug behaviors. This review discusses the issues that most affect the clinical utility of drug testing in chronic pain management with opioid therapy. It focuses on the two most commonly used specimen matrices in drug testing: urine and oral fluid. The advantages and disadvantages of urine and oral fluid in the entire testing process, from specimen collection and analytical methodologies to result interpretation are reviewed. The analytical sensitivity and specificity limitations of immunoassays used for testing are examined in detail to draw attention to how these shortcomings can affect result interpretation and influence clinical decision-making in pain management. The need for specific identification and quantitative measurement of the drugs and metabolites present to investigate suspected aberrant drug behavior or unexpected positive results is analyzed. Also presented are recent developments in optimization of test menus and testing strategies, such as the modification of the standard screen and reflexed-confirmation testing model by eliminating some of the initial immunoassay-based tests and proceeding directly to definitive testing by mass spectrometry assays.
... one urine sample (protein-to-creatinine ratio). Normal Results The normal value is less than 100 milligrams ... meaning of your specific test results. What Abnormal Results Mean Abnormal results may be due to: A ...
Microarray-based IgE detection in tears of patients with vernal keratoconjunctivitis.
Leonardi, Andrea; Borghesan, Franco; Faggian, Diego; Plebani, Mario
2015-11-01
A specific allergen sensitization can be demonstrated in approximately half of the vernal keratoconjunctivitis (VKC) patients by conventional allergic tests. The measurement of specific IgE in tears using a multiplex allergen microarray may offer advantages to identify local sensitization to a specific allergen. In spring-summer 2011, serum and tears samples were collected from 10 active VKC patients (three females, seven males) and 10 age-matched normal subjects. Skin prick test, symptoms score and full ophthalmological examination were performed. Specific serum and tear IgE were assayed using ImmunoCAP ISAC, a microarray containing 103 components derived from 47 allergens. Normal subjects resulted negative for the presence of specific IgE both in serum and in tears. Of the 10 VKC patients, six resulted positive to specific IgE in serum and/or tears. In three of these six patients, specific IgE was found positive only in tears. Cross-reactivity between specific markers was found in three patients. Grass, tree, mites, animal but also food allergen-specific IgE were found in tears. Conjunctival provocation test performed out of season confirmed the specific local conjunctival reactivity. Multiple specific IgE measurements with single protein allergens using a microarray technique in tear samples are a useful, simple and non-invasive diagnostic tool. ImmunoCAP ISAC detects allergen sensitization at component level and adds important information by defining both cross- and co-sensitization to a large variety of allergen molecules. The presence of specific IgE only in tears of VKC patients reinforces the concept of possible local sensitization. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Rodríguez-Rosell, David; Mora-Custodio, Ricardo; Franco-Márquez, Felipe; Yáñez-García, Juan M; González-Badillo, Juan J
2017-01-01
Rodríguez-Rosell, D, Mora-Custodio, R, Franco-Márquez, F, Yáñez-García, JM, González-Badillo, JJ. Traditional vs. sport-specific vertical jump tests: reliability, validity, and relationship with the legs strength and sprint performance in adult and teen soccer and basketball players. J Strength Cond Res 31(1): 196-206, 2017-The vertical jump is considered an essential motor skill in many team sports. Many protocols have been used to assess vertical jump ability. However, controversy regarding test selection still exists based on the reliability and specificity of the tests. The main aim of this study was to analyze the reliability and validity of 2 standardized (countermovement jump [CMJ] and Abalakov jump [AJ]) and 2 sport-specific (run-up with 2 [2-LEGS] or 1 leg [1-LEG] take-off jump) vertical jump tests, and their usefulness as predictors of sprint and strength performance for soccer (n = 127) and basketball (n = 59) players in 3 different categories (Under-15, Under-18, and Adults). Three attempts for each of the 4 jump tests were recorded. Twenty-meter sprint time and estimated 1 repetition maximum in full squat were also evaluated. All jump tests showed high intraclass correlation coefficients (0.969-0.995) and low coefficients of variation (1.54-4.82%), although 1-LEG was the jump test with the lowest absolute and relative reliability. All selected jump tests were significantly correlated (r = 0.580-0.983). Factor analysis resulted in the extraction of one principal component, which explained 82.90-95.79% of the variance of all jump tests. The 1-LEG test showed the lowest associations with sprint and strength performance. The results of this study suggest that CMJ and AJ are the most reliable tests for the estimation of explosive force in soccer and basketball players in different age categories.
Comparing Postsecondary Marketing Student Performance on Computer-Based and Handwritten Essay Tests
ERIC Educational Resources Information Center
Truell, Allen D.; Alexander, Melody W.; Davis, Rodney E.
2004-01-01
The purpose of this study was to determine if there were differences in postsecondary marketing student performance on essay tests based on test format (i.e., computer-based or handwritten). Specifically, the variables of performance, test completion time, and gender were explored for differences based on essay test format. Results of the study…
True versus Apparent Malaria Infection Prevalence: The Contribution of a Bayesian Approach
Claes, Filip; Van Hong, Nguyen; Torres, Kathy; Mao, Sokny; Van den Eede, Peter; Thi Thinh, Ta; Gamboa, Dioni; Sochantha, Tho; Thang, Ngo Duc; Coosemans, Marc; Büscher, Philippe; D'Alessandro, Umberto; Berkvens, Dirk; Erhart, Annette
2011-01-01
Aims To present a new approach for estimating the “true prevalence” of malaria and apply it to datasets from Peru, Vietnam, and Cambodia. Methods Bayesian models were developed for estimating both the malaria prevalence using different diagnostic tests (microscopy, PCR & ELISA), without the need of a gold standard, and the tests' characteristics. Several sources of information, i.e. data, expert opinions and other sources of knowledge can be integrated into the model. This approach resulting in an optimal and harmonized estimate of malaria infection prevalence, with no conflict between the different sources of information, was tested on data from Peru, Vietnam and Cambodia. Results Malaria sero-prevalence was relatively low in all sites, with ELISA showing the highest estimates. The sensitivity of microscopy and ELISA were statistically lower in Vietnam than in the other sites. Similarly, the specificities of microscopy, ELISA and PCR were significantly lower in Vietnam than in the other sites. In Vietnam and Peru, microscopy was closer to the “true” estimate than the other 2 tests while as expected ELISA, with its lower specificity, usually overestimated the prevalence. Conclusions Bayesian methods are useful for analyzing prevalence results when no gold standard diagnostic test is available. Though some results are expected, e.g. PCR more sensitive than microscopy, a standardized and context-independent quantification of the diagnostic tests' characteristics (sensitivity and specificity) and the underlying malaria prevalence may be useful for comparing different sites. Indeed, the use of a single diagnostic technique could strongly bias the prevalence estimation. This limitation can be circumvented by using a Bayesian framework taking into account the imperfect characteristics of the currently available diagnostic tests. As discussed in the paper, this approach may further support global malaria burden estimation initiatives. PMID:21364745
Routine use of point-of-care tests: usefulness and application in clinical microbiology.
Clerc, O; Greub, G
2010-08-01
Point-of-care (POC) tests offer potentially substantial benefits for the management of infectious diseases, mainly by shortening the time to result and by making the test available at the bedside or at remote care centres. Commercial POC tests are already widely available for the diagnosis of bacterial and viral infections and for parasitic diseases, including malaria. Infectious diseases specialists and clinical microbiologists should be aware of the indications and limitations of each rapid test, so that they can use them appropriately and correctly interpret their results. The clinical applications and performance of the most relevant and commonly used POC tests are reviewed. Some of these tests exhibit insufficient sensitivity, and should therefore be coupled to confirmatory tests when the results are negative (e.g. Streptococcus pyogenes rapid antigen detection test), whereas the results of others need to be confirmed when positive (e.g. malaria). New molecular-based tests exhibit better sensitivity and specificity than former immunochromatographic assays (e.g. Streptococcus agalactiae detection). In the coming years, further evolution of POC tests may lead to new diagnostic approaches, such as panel testing, targeting not just a single pathogen, but all possible agents suspected in a specific clinical setting. To reach this goal, the development of serology-based and/or molecular-based microarrays/multiplexed tests will be needed. The availability of modern technology and new microfluidic devices will provide clinical microbiologists with the opportunity to be back at the bedside, proposing a large variety of POC tests that will allow quicker diagnosis and improved patient care.
Resch, Jacob E; Brown, Cathleen N; Schmidt, Julianne; Macciocchi, Stephen N; Blueitt, Damond; Cullum, C Munro; Ferrara, Michael S
2016-01-01
Context A battery of clinical measures of neurocognition, balance and symptoms has been recommended for the management of sport concussion (SC) but is based on variable evidence. Objective To examine the sensitivity and specificity of a battery of tests to assess SC in college athletes. Design Cross-sectional. Setting Research laboratory. Patients or other participants Division 1 athletes diagnosed with a SC (n=40) who were 20.2±1.60 years of age and 180.5±11.12 cm tall and healthy athletes (n=40) who were 19.0±0.93 years of age and 179.1±11.39 cm tall were enrolled. Intervention(s) Participants were administered Immediate Postconcussion Assessment and Cognitive Test (ImPACT), the Sensory Organization Test (SOT) and the Revised Head Injury Scale (HIS-r) prior to and up to 24 h following injury between the 2004 and 2014 sport seasons. Sensitivity and specificity were calculated using predictive discriminant analyses (PDA) and clinical interpretation guidelines. Main outcome measures Outcome measures included baseline and postinjury ImPACT, SOT and HIS-r composite scores. Results Using PDA, each clinical measure's sensitivity ranged from 55.0% to 77.5% and specificity ranged from 52.5% to 100%. The test battery possessed a sensitivity and specificity of 80.0% and 100%, respectively. Using clinical interpretation guidelines, sensitivity ranged from 55% to 97.5% individually, and 100% when combined. Conclusions Our results support a multidimensional approach to assess SC in college athletes which correctly identified 80–100% of concussed participants as injured. When each test was evaluated separately, up to 47.5% of our sample was misclassified. Caution is warranted when using singular measures to manage SC. PMID:27900145
Michałowska, Martyna; Walczak, Tomasz; Owen, Adam; Grabski, Jakub Krzysztof; Pyda, Andrzej; Piontek, Tomasz; Kotwicki, Tomasz
2017-01-01
Objective To measure the sensitivity and specificity of differences cut-off values for isokinetic Hcon/Qcon ratio in order to improve the capacity to evaluate (retrospectively) the injury of hamstring muscles in professional soccer screened with knee isokinetic tests. Design Retrospective study. Methods Medical and biomechanical data of professional football players playing for the same team for at least one season between 2010 and 2016 were analysed. Hamstring strain injury cases and the reports generated via isokinetic testing were investigated. Isokinetic concentric(con) hamstring(H) and quadriceps(Q) absolute strength in addition with Hcon/Qcon ratio were examined for the injured versus uninjured limbs among injured players, and for the injured and non-injured players. 2 x 2 contingency table was used for comparing variables: predicted injured or predicted uninjured with actual injured or actual uninjured. Sensitivity, specificity, accuracy, positive and negative predictive values, and positive and negative likelihood ratio were calculated for three different cut-off values (0.47 vs. 0.6 vs. 0.658) to compare the discriminative power of an isokinetic test, whilst examining the key value of Hcon/Qcon ratio which may indicate the highest level of ability to predispose a player to injury. McNemar’s chi2 test with Yates’s correction was used to determine agreement between the tests. PQStat software was used for all statistical analysis, and an alpha level of p <0.05 was used for all statistical comparisons. Results 340 isokinetic test reports on both limbs of 66 professional soccer players were analysed. Eleven players suffered hamstring injuries during the analysed period. None of these players sustained recurrence of hamstring injury. One player sustained hamstring strain injury on both legs, thus the total number of injuries was 12. Application of different cut-off values for Hcon/Qcon significantly affected the sensitivity and specificity of isokinetic test used as a tool for muscle injury detection. The use of 0.47 of Hcon/Qcon as a discriminate value resulted in significantly lower sensitivity when compared to 0.658 threshold (sensitivity of 16.7% vs. 91.7%, respectively; t = 6.125,p = 0.0133). Calculated values of specificity (when three different cut-off were applied) were also significantly different. Threshold of 0.6 of Hcon/Qcon resulted with significantly lower specificity compared to 0.47 value (specificity of 46.9% vs. 94.5%, respectively; t = 153.0,p<0.0001), and significantly higher specificity when compared to 0.658 (specificity of 46.9% vs. 24.1%, respectively; t = 229.0, p<0.0001). Conclusion The use of different cut-off values for Hcon/Qcon significantly affected the sensitivity and specificity of isokinetic testing. The interpretation of usefulness of isokinetic test as a screening tool in a group of male professional football players to predict hamstring injury occurrence within the next 12 months might be therefore significantly biased due to the different threshold values of Hcon/Qcon. Using one “normative” value as a cut-off (e.g. 0.47 or 0.60, or 0.658) to quantify soccer players (or not) to the group with a higher risk of knee injury might result in biased outcomes due to the natural strength asymmetry that is observed within the group of soccer players. PMID:29216241
Kunkle, Gerald A.
2016-01-07
The Sutron 8310-N-S (8310) data collection platform (DCP) manufactured by Sutron Corporation was evaluated by the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) for conformance to the manufacturer’s specifications for recording and transmitting data. The 8310-N-S is a National Electrical Manufacturers Association (NEMA)-enclosed DCP with a built-in Geostationary Operational Environmental Satellite transmitter that operates over a temperature range of −40 to 60 degrees Celsius (°C). The evaluation procedures followed and the results obtained are described in this report for bench, temperature chamber, and outdoor deployment testing. The three units tested met the manufacturer’s stated specifications for the tested conditions, but two of the units had transmission errors either during temperature chamber or deployment testing. During outdoor deployment testing, 6.72 percent of transmissions by serial number 1206109 contained errors, resulting in missing data. Transmission errors were also observed during temperature chamber testing with serial number 1208283, at an error rate of 3.22 percent. Overall, the 8310 has good logging capabilities, but the transmission errors are a concern for users who require reliable telemetered data.
Mouza, AM
2008-01-01
In this paper we present a model to evaluate the effect of certain majors socioeconomic factors (such as alcohol and fat consumption, cigarettes smoking, unemployment rate as a proxy for uncertainty which results frustration, number of passenger cars as a proxy for physical exercise and per capita GDP as a proxy for nutrition quality), to the ischemic mortality rate. Since the existing research works on this field, suffer from the proper model testing, we analytically present all the tests necessary to justify the reliability of the result obtained. For this purpose, after specifying and estimating the model, we applied the specification error test, the linearity, multicollinearity and heteroscedasticity tests, the autocorrelation and stability tests and the ARCH effect test. Finally, we present the aggregate efect of the above socioeconomic factors. In brief, we found that an increase of cigarettes smoked, of fat and alcohol consumption and the number of passenger cars will result to a relevant increase regarding mortality. The latter one is also affected by the changes in unemployment rate. On the other hand, an increase of personal disposable income may negatively affect mortality, by almost the same portion. PMID:18923751
Mouza, A M
2008-01-01
In this paper we present a model to evaluate the effect of certain majors socioeconomic factors (such as alcohol and fat consumption, cigarettes smoking, unemployment rate as a proxy for uncertainty which results frustration, number of passenger cars as a proxy for physical exercise and per capita GDP as a proxy for nutrition quality), to the ischemic mortality rate. Since the existing research works on this field, suffer from the proper model testing, we analytically present all the tests necessary to justify the reliability of the result obtained. For this purpose, after specifying and estimating the model, we applied the specification error test, the linearity, multicollinearity and heteroscedasticity tests, the autocorrelation and stability tests and the ARCH effect test. Finally, we present the aggregate effect of the above socioeconomic factors. In brief, we found that an increase of cigarettes smoked, of fat and alcohol consumption and the number of passenger cars will result to a relevant increase regarding mortality. The latter one is also affected by the changes in unemployment rate. On the other hand, an increase of personal disposable income may negatively affect mortality, by almost the same portion.
Brockow, Knut; Kneissl, Daniel; Valentini, Luzia; Zelger, Otto; Grosber, Martine; Kugler, Claudia; Werich, Martina; Darsow, Ulf; Matsuo, Hiroaki; Morita, Eishin; Ring, Johannes
2015-04-01
Oral wheat plus cofactors challenge tests in patients with wheat-dependent exercise-induced anaphylaxis (WDEIA) produce unreliable results. We sought to confirm WDEIA diagnosis by using oral gluten flour plus cofactors challenge, to determine the amount of gluten required to elicit symptoms, and to correlate these results with plasma gliadin levels, gastrointestinal permeability, and allergologic parameters. Sixteen of 34 patients with a history of WDEIA and ω5-gliadin IgE underwent prospective oral challenge tests with gluten with or without cofactors until objective symptoms developed. Gluten reaction threshold levels, plasma gliadin concentrations, gastrointestinal permeability, sensitivities and specificities for skin prick tests, and specific IgE levels were ascertained in patients and 38 control subjects. In 16 of 16 patients (8 female and 8 male patients; age, 23-76 years), WDEIA was confirmed by challenges with gluten alone (n = 4) or gluten plus cofactors (n = 12), including 4 patients with previous negative wheat challenge results. Higher gluten doses or acetylsalicylic acid (ASA) plus alcohol instead of physical exercise were cofactors in 2 retested patients. The cofactors ASA plus alcohol and exercise increased plasma gliadin levels (P < .03). Positive challenge results developed after a variable period of time at peak or when the plateau plasma gliadin level was attained. Positive plasma gliadin threshold levels differed by greater than 100-fold and ranged from 15 to 2111 pg/mL (median, 628 pg/mL). The clinical history, IgE gliadin level, and baseline gastrointestinal level were not predictive of the outcomes of the challenge tests. The challenge-confirmed sensitivity and specificity of gluten skin prick tests was 100% and 96%, respectively. Oral challenge with gluten alone or along with ASA and alcohol is a sensitive and specific test for the diagnosis of WDEIA. Exercise is not an essential trigger for the onset of symptoms in patients with WDEIA. Copyright © 2014 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Mod-2 wind turbine project assessment and cluster test plans
NASA Technical Reports Server (NTRS)
Gordon, L. H.
1982-01-01
An assessment of the Mod-2 Wind Turbine project is presented based on initial goals and present results. Specifically, the Mod-2 background, project flow, and a chronology of events/results leading to Mod-2 acceptance is presented. After checkout/acceptance of the three operating turbines, NASA/LeRC will continue management of a two year test program performed at the DOE Goodnoe Hills test site. This test program is expected to yield data necessary for the continued development and optimization of wind energy systems. These test activities, the implementation of, and the results to date are also presented.
Statistical EMC: A new dimension electromagnetic compatibility of digital electronic systems
NASA Astrophysics Data System (ADS)
Tsaliovich, Anatoly
Electromagnetic compatibility compliance test results are used as a database for addressing three classes of electromagnetic-compatibility (EMC) related problems: statistical EMC profiles of digital electronic systems, the effect of equipment-under-test (EUT) parameters on the electromagnetic emission characteristics, and EMC measurement specifics. Open area test site (OATS) and absorber line shielded room (AR) results are compared for equipment-under-test highest radiated emissions. The suggested statistical evaluation methodology can be utilized to correlate the results of different EMC test techniques, characterize the EMC performance of electronic systems and components, and develop recommendations for electronic product optimal EMC design.
Gomes de Oliveira, Geilson; Eleutério, Renata Mirian Nunes; Silveira Gonçalves, Ana Katherine; Giraldo, Paulo César; Eleutério, José
2018-01-01
The aim of this study was to assess the correlation between atypical squamous cells (ASC) and inflammatory infiltrate and vaginal microbiota using cervical liquid-based cytological (SurePath®) and high-risk human papillomavirus (HR-HPV) tests. A cross-sectional study was conducted using a 6-year database from a laboratory in Fortaleza (Brazil). Files from 1,346 ASC cases were divided into subgroups and results concerning inflammation and vaginal microorganisms diagnosed by cytology were compared with HR-HPV test results. An absence of specific microorganisms (ASM) was the most frequent finding (ASC of undetermined significance, ASC-US = 74%; ASC - cannot exclude high-grade squamous intraepithelial lesion, ASC-H = 68%), followed by bacterial vaginosis (ASC-US = 20%; ASC- H = 25%) and Candida spp. (ASC-US = 6%; ASC-H = 5%). Leukocyte infiltrate was present in 71% of ASC-US and 85% of ASC-H (p = 0.0040), and in these specific cases HR-HPV tests were positive for 65 and 64%, respectively. A positive HR-HPV test was relatively more frequent when a specific microorganism was present, and Candida spp. was associated with HR-HPV-positive results (p = 0.0156), while an ASM was associated with negative HR-HPV results (p = 0.0370). ASC-US is associated with an absence of inflammation or vaginosis, while ASC-H smears are associated with Trichomonas vaginalis and inflammatory infiltrate. A positive HR-HPV is associated with Candida spp. in ASC cytology. © 2017 S. Karger AG, Basel.
McMillin, Gwendolyn A; Marin, Stephanie J; Johnson-Davis, Kamisha L; Lawlor, Bryan G; Strathmann, Frederick G
2015-02-01
The major objective of this research was to propose a simplified approach for the evaluation of medication adherence in chronic pain management patients, using liquid chromatography time-of-flight (TOF) mass spectrometry, performed in parallel with select homogeneous enzyme immunoassays (HEIAs). We called it a "hybrid" approach to urine drug testing. The hybrid approach was defined based on anticipated positivity rates, availability of commercial reagents for HEIAs, and assay performance, particularly analytical sensitivity and specificity for drug(s) of interest. Subsequent to implementation of the hybrid approach, time to result was compared with that observed with other urine drug testing approaches. Opioids, benzodiazepines, zolpidem, amphetamine-like stimulants, and methylphenidate metabolite were detected by TOF mass spectrometry to maximize specificity and sensitivity of these 37 drug analytes. Barbiturates, cannabinoid metabolite, carisoprodol, cocaine metabolite, ethyl glucuronide, methadone, phencyclidine, propoxyphene, and tramadol were detected by HEIAs that performed adequately and/or for which positivity rates were very low. Time to result was significantly reduced compared with the traditional approach. The hybrid approach to urine drug testing provides a simplified and analytically specific testing process that minimizes the need for secondary confirmation. Copyright© by the American Society for Clinical Pathology.
Ochodo, Eleanor A; Gopalakrishna, Gowri; Spek, Bea; Reitsma, Johannes B; van Lieshout, Lisette; Polman, Katja; Lamberton, Poppy; Bossuyt, Patrick Mm; Leeflang, Mariska Mg
2015-01-01
Background Point-of-care (POC) tests for diagnosing schistosomiasis include tests based on circulating antigen detection and urine reagent strip tests. If they had sufficient diagnostic accuracy they could replace conventional microscopy as they provide a quicker answer and are easier to use. Objectives To summarise the diagnostic accuracy of: a) urine reagent strip tests in detecting active Schistosoma haematobium infection, with microscopy as the reference standard; and b) circulating antigen tests for detecting active Schistosoma infection in geographical regions endemic for Schistosoma mansoni or S. haematobium or both, with microscopy as the reference standard. Search methods We searched the electronic databases MEDLINE, EMBASE, BIOSIS, MEDION, and Health Technology Assessment (HTA) without language restriction up to 30 June 2014. Selection criteria We included studies that used microscopy as the reference standard: for S. haematobium, microscopy of urine prepared by filtration, centrifugation, or sedimentation methods; and for S. mansoni, microscopy of stool by Kato-Katz thick smear. We included studies on participants residing in endemic areas only. Data collection and analysis Two review authors independently extracted data, assessed quality of the data using QUADAS-2, and performed meta-analysis where appropriate. Using the variability of test thresholds, we used the hierarchical summary receiver operating characteristic (HSROC) model for all eligible tests (except the circulating cathodic antigen (CCA) POC for S. mansoni, where the bivariate random-effects model was more appropriate). We investigated heterogeneity, and carried out indirect comparisons where data were sufficient. Results for sensitivity and specificity are presented as percentages with 95% confidence intervals (CI). Main results We included 90 studies; 88 from field settings in Africa. The median S. haematobium infection prevalence was 41% (range 1% to 89%) and 36% for S. mansoni (range 8% to 95%). Study design and conduct were poorly reported against current standards. Tests for S. haematobium Urine reagent test strips versus microscopy Compared to microscopy, the detection of microhaematuria on test strips had the highest sensitivity and specificity (sensitivity 75%, 95% CI 71% to 79%; specificity 87%, 95% CI 84% to 90%; 74 studies, 102,447 participants). For proteinuria, sensitivity was 61% and specificity was 82% (82,113 participants); and for leukocyturia, sensitivity was 58% and specificity 61% (1532 participants). However, the difference in overall test accuracy between the urine reagent strips for microhaematuria and proteinuria was not found to be different when we compared separate populations (P = 0.25), or when direct comparisons within the same individuals were performed (paired studies; P = 0.21). When tests were evaluated against the higher quality reference standard (when multiple samples were analysed), sensitivity was marginally lower for microhaematuria (71% vs 75%) and for proteinuria (49% vs 61%). The specificity of these tests was comparable. Antigen assay Compared to microscopy, the CCA test showed considerable heterogeneity; meta-analytic sensitivity estimate was 39%, 95% CI 6% to 73%; specificity 78%, 95% CI 55% to 100% (four studies, 901 participants). Tests for S. mansoni Compared to microscopy, the CCA test meta-analytic estimates for detecting S. mansoni at a single threshold of trace positive were: sensitivity 89% (95% CI 86% to 92%); and specificity 55% (95% CI 46% to 65%; 15 studies, 6091 participants) Against a higher quality reference standard, the sensitivity results were comparable (89% vs 88%) but specificity was higher (66% vs 55%). For the CAA test, sensitivity ranged from 47% to 94%, and specificity from 8% to 100% (4 studies, 1583 participants). Authors' conclusions Among the evaluated tests for S. haematobium infection, microhaematuria correctly detected the largest proportions of infections and non-infections identified by microscopy. The CCA POC test for S. mansoni detects a very large proportion of infections identified by microscopy, but it misclassifies a large proportion of microscopy negatives as positives in endemic areas with a moderate to high prevalence of infection, possibly because the test is potentially more sensitive than microscopy. Plain Language Summary How well do point-of-care tests detect Schistosoma infections in people living inendemic areas? Schistosomiasis, also known as bilharzia, is a parasitic disease common in the tropical and subtropics. Point-of-care tests and urine reagent strip tests are quicker and easier to use than microscopy. We estimate how well these point-of-care tests are able to detect schistosomiasis infections compared with microscopy. We searched for studies published in any language up to 30 June 2014, and we considered the study’s risk of providing biased results. What do the results say? We included 90 studies involving almost 200,000 people, with 88 of these studies carried out in Africa in field settings. Study design and conduct were poorly reported against current expectations. Based on our statistical model, we found: • Among the urine strips for detecting urinary schistosomiasis, the strips for detecting blood were better than those detecting protein or white cells (sensitivity and specificity for blood 75% and 87%; for protein 61% and 82%; and for white cells 58% and 61%, respectively). • For urinary schistosomiasis, the parasite antigen test performance was worse (sensitivity, 39% and specificity, 78%) than urine strips for detecting blood. • For intestinal schistosomiasis, the parasite antigen urine test, detected many infections identified by microscopy but wrongly labelled many uninfected people as sick (sensitivity, 89% and specificity, 55%). What are the consequences of using these tests? If we take 1000 people, of which 410 have urinary schistosomiasis on microscopy testing, then using the strip detecting blood in the urine would misclassify 77 uninfected people as infected, and thus may receive unnecessary treatment; and it would wrongly classify 102 infected people as uninfected, who thus may not receive treatment. If we take 1000 people, of which 360 have intestinal schistosomiasis on microscopy testing, then the antigen test would misclassify 288 uninfected people as infected. These people may be given unnecessary treatment. This test also would wrongly classify 40 infected people as uninfected who thus may not receive treatment. Conclusion of review For urinary schistosomiasis, the urine strip for detecting blood leads to some infected people being missed and some non-infected people being diagnosed with the condition, but is better than the protein or white cell tests. The parasite antigen test is not accurate. For intestinal schistosomiasis, the parasite antigen urine test can wrongly classify many uninfected people as infected. PMID:25758180
Mallett, Susan; Halligan, Steve; Collins, Gary S; Altman, Doug G
2014-01-01
Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests.
Biological markers of melancholia and reclassification of depressive disorders.
Greden, J F
1982-01-01
Pathophysiological markers of melancholia are being developed in four major areas: 1) neuroendocrine; 2) sleep; 3) psychomotor and 4) biochemical. Neuroendocrine markers include a failure of suppress plasma cortisol secretion in the dexamethasone suppression test (DST), diminished thyrotrophin (TSH) response to thyrotrophin releasing hormone (TRH stimulation test), and blunted growth hormone response to a variety of stimulating agents such as d-amphetamine, methylamphetamine, clonidine, L-dopa and insulin (growth hormone test). Of these, the DST is the best standardized. It is a highly specific laboratory marker with documented value in diagnosis, assessing prognosis and monitoring treatment progress. Sleep EEG abnormalities include reduced REM latency, increased REM density, reduction in delta sleep and impaired sleep efficiency. Sleep EEGs are pragmatically difficult, but results are quite specific. Elongated speech pause time (SPT) during "automatic speech" is a promising marker of psychomotor regulation. This simple, non-invasive measure may have special value in reducing clinical subjectivity and in monitoring treatment progress. Biochemical markers include: 1) platelet monoamine oxidase (MAO) activity; 2) in vitro lithium RBC transport and 3) urinary MHPG levels. Standardizations of biochemical tests are still lacking. Most biological tests for melancholia operate by indirectly "marking" CNS limbic system dysfunction. For wide acceptance, a test must be safe, moderately sensitive, highly specific, practical, relatively inexpensive and not significantly altered by common anti-depressant treatments. The DST best meets these criteria at this time. Proper utilization of test results requires knowledge of baseline prevalence rates and of the concepts of sensitivity (true-positive rate), specificity (true negative rate) and positive and negative predictive values (diagnostic confidence). No single marker will meet all clinical needs. Combinations or serial use of tests will hopefully enhance their already considerable usefulness.
OPERATION CROSSROADS. Test of Target Airplane, Model TBM-3E, Serial Number 69169
1950-04-25
Water Absorption. XIX Plastic Test Results - Specific Gravity . XX Port Tire Tent Results. XXI Inner Tube Test Results. XXI Self-Sealing Fuel Cell...prev4ously run on non-radioactive meterials . (b) Tht report describes the daTge suffered by c3rtain materials, and the points of failure and the non...conlucted on 1I tEin’. 1j and b in accnrd:ýtnce thith ~i~ethcd 70,31 of S&ecificuitir~n Li-Ga (14) Sjeiific Gravity - Tests were conducted on Yeter~l,,ls
[How good are clinical investigative procedures for diagnosing meniscus lesions?].
Jerosch, J; Riemer, S
2004-06-01
The purpose of this study was to evaluate different clinical meniscus tests. During 13 months we evaluated 64 patients with a suspected meniscus lesion in a prospective study. The age ranged from 16 to 76 years (average: 38.5 years). 66 % were male patients. Between the clinical examination and the arthroscopy there was no additional trauma to the knee. All patients were clinically examined in a standard manner by two independent orthopaedic surgeons. Clinical findings of the menisci were documented according to 12 well-described and commonly used meniscus tests. The arthroscopy was performed by a single surgeon who was not aware of the results of the clinical examination. This surgeon documented the intraarticular findings in a standardized operating report. A meniscus lesion/degeneration was documented when this was evident either by inspection or by palpation. The results showed either clinical meniscus tests with a high specificity and a low sensitivity or tests with a high sensitivity, but only a low specificity. We were not able to identify meniscus tests which showed both a high sensitivity and a high specificity. Even with access to MRI the clinical findings in knee joint with injured menisci still have a high diagnostic value. However, it seems to be necessary to combine different tests.
Genchi, Marco; Mangia, Carlo; Ferrari, Nicola; Loukeri, Sofia
2018-01-01
The performance of a rapid immunochromatographic test for the detection of Dirofilaria immitis antigens (Speed Diro™; BVT-Virbac, France) was assessed in 49 experimentally infected dogs and in 244 naturally infected animals; 142 dogs and 102 cats. In experimentally infected dogs, Speed Diro™ showed a sensitivity of 90.9% in dogs infected with one adult female worm and 100% in dogs infected with more than one female worm. Specificity was 100%. For naturally infected dogs, the Knott test and PetChek ® HTWM PF served as reference methods for microfilaremia and antigenemia, respectively. All microfilaemic dogs (55/142) were positive with Speed Diro™. Importantly, none of the 21 dogs infected with D. repens were positive. The results of Speed Diro™ for the detection of antigenemia were compared with two in-house tests, SNAP ® HTWM and Witness ® Dirofilaria, and all three tests were 100% specific and sensitive in comparison to PetChek ® HTWM PF. For the evaluation of feline samples, 102 cats were examined by echocardiography. Sera from 87 heartworm-infected cats were tested by Speed Diro™ and SNAP ® HTWM. The results of Speed Diro™ were equivalent to SNAP ® HTWM, with a sensitivity of 98.9% and a specificity of 100%.
Bayesian Item Selection in Constrained Adaptive Testing Using Shadow Tests
ERIC Educational Resources Information Center
Veldkamp, Bernard P.
2010-01-01
Application of Bayesian item selection criteria in computerized adaptive testing might result in improvement of bias and MSE of the ability estimates. The question remains how to apply Bayesian item selection criteria in the context of constrained adaptive testing, where large numbers of specifications have to be taken into account in the item…
Experimental uncertainty survey and assessment. [Space Shuttle Main Engine testing
NASA Technical Reports Server (NTRS)
Coleman, Hugh W.
1992-01-01
An uncertainty analysis and assessment of the specific impulse determination during Space Shuttle Main Engine testing is reported. It is concluded that in planning and designing tests and in interpreting the results of tests, the bias and precision components of experimental uncertainty should be considered separately. Recommendations for future research efforts are presented.
Understanding the properties of diagnostic tests - Part 2: Likelihood ratios.
Ranganathan, Priya; Aggarwal, Rakesh
2018-01-01
Diagnostic tests are used to identify subjects with and without disease. In a previous article in this series, we examined some attributes of diagnostic tests - sensitivity, specificity, and predictive values. In this second article, we look at likelihood ratios, which are useful for the interpretation of diagnostic test results in everyday clinical practice.
Technology diffusion and diagnostic testing for prostate cancer.
Schroeck, Florian R; Kaufman, Samuel R; Jacobs, Bruce L; Skolarus, Ted A; Miller, David C; Weizer, Alon Z; Montgomery, Jeffrey S; Wei, John T; Shahinian, Vahakn B; Hollenbeck, Brent K
2013-11-01
While the dissemination of robotic prostatectomy and intensity modulated radiotherapy may fuel the increased use of prostatectomy and radiotherapy, these new technologies may also have spillover effects related to diagnostic testing for prostate cancer. Therefore, we examined the association of regional technology penetration with the receipt of prostate specific antigen testing and prostate biopsy. In this retrospective cohort study we included 117,857 men 66 years old or older from the 5% sample of Medicare beneficiaries living in Surveillance, Epidemiology and End Results (SEER) areas from 2003 to 2007. Regional technology penetration was measured as the number of providers performing robotic prostatectomy or intensity modulated radiotherapy per population in a health care market, ie hospital referral region. We assessed the association of technology penetration with the prostate specific antigen testing rate and prostate biopsy using generalized estimating equations. High technology penetration was associated with an increased rate of prostate specific antigen testing (442 vs 425/1,000 person-years, p<0.01) and a similar rate of prostate biopsy (10.1 vs 9.9/1,000 person-years, p=0.69). The impact of technology penetration on prostate specific antigen testing and prostate biopsy was much less than the effect of age, race and comorbidity, eg the prostate specific antigen testing rate per 1,000 person-years was 485 vs 373 for men with only 1 vs 3+ comorbid conditions (p<0.01). Increased technology penetration is associated with a slightly higher rate of prostate specific antigen testing and no change in the prostate biopsy rate. Collectively, our findings temper concerns that adopting new technology accelerates diagnostic testing for prostate cancer. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Dieste-Pérez, L; Blasco, J M; de Miguel, M J; Moriyón, I; Muñoz, P M
2015-04-01
Swine brucellosis caused by Brucella suis biovar 2 is an emerging disease in Europe. Currently used diagnostic tests for swine brucellosis detect antibodies to the O-polysaccharide (O-PS) of Brucella smooth lipopolysaccharide (S-LPS) but their specificity is compromised by false-positive serological reactions (FPSRs) when bacteria carrying cross-reacting O-PS infect pigs. FPSRs occur throughout Europe, and the only tool available for a specific B. suis diagnosis is the intradermal test with Brucella protein extracts free of O-PS or S-LPS. Using sera of 162 sows naturally infected by B. suis biovar 2, 406 brucellosis-free sows, and 218 pigs of brucellosis-free farms affected by FPSR, we assessed the diagnostic performance of an indirect ELISA with rough LPS (thus devoid of O-PS) and of gel immunodiffusion, counterimmunoelectrophoresis, latex agglutination and indirect ELISA with O-PS free proteins in comparison with several S-LPS tests (Rose Bengal, complement fixation, gel immunodiffusion and indirect ELISA). When adjusted to 100% specificity, the sensitivity of the rough LPS ELISA was very low (30%), and adoption of other cut-offs resulted in poor specificity/sensitivity ratios. Although their specificity was 100%, the sensitivity of protein tests (ELISA, latex agglutination, counterimmunoelectrophoresis, and gel immunodiffusion) was only moderate (45, 58, 61 and 63%, respectively). Among S-LPS tests, gel immunodiffusion was the only test showing acceptable sensitivity/specificity (68 and 100%, respectively). Despite these shortcomings, and when the purpose is to screen out FPSR at herd level, gel immunodiffusion tests may offer a technically simple and practical alternative to intradermal testing. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Anderson, Gustave
2014-05-01
Unfortunately, there is no metric, nor set of metrics, that are both general enough to encompass all possible types of applications yet specific enough to capture the application and attack specific details. As a result we are left with ad-hoc methods for generating evaluations of the security of our systems. Current state of the art methods for evaluating the security of systems include penetration testing and cyber evaluation tests. For these evaluations, security professionals simulate an attack from malicious outsiders and malicious insiders. These evaluations are very productive and are able to discover potential vulnerabilities resulting from improper system configuration, hardware and software flaws, or operational weaknesses. We therefore propose the index of cyber integrity (ICI), which is modeled after the index of biological integrity (IBI) to provide a holistic measure of the health of a system under test in a cyber-environment. The ICI provides a broad base measure through a collection of application and system specific metrics. In this paper, following the example of the IBI, we demonstrate how a multi-metric index may be used as a holistic measure of the health of a system under test in a cyber-environment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hart, Darren M.
Sandia National Laboratories has tested and evaluated Geotech Smart24 data acquisition system with active Fortezza crypto card data signing and authentication. The test results included in this report were in response to static and tonal-dynamic input signals. Most test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters; others were designed by Sandia specifically for infrasound application evaluation and for supplementary criteria not addressed in the IEEE standards. The objective of this work was to evaluate the overall technical performance of the Geotech Smart24 digitizer with a Fortezza PCMCIA cryptomore » card actively implementing the signing of data packets. The results of this evaluation were compared to relevant specifications provided within manufacturer's documentation notes. The tests performed were chosen to demonstrate different performance aspects of the digitizer under test. The performance aspects tested include determining noise floor, least significant bit (LSB), dynamic range, cross-talk, relative channel-to-channel timing, time-tag accuracy, analog bandwidth and calibrator performance.« less
Evaluation of various thrust calculation techniques on an F404 engine
NASA Technical Reports Server (NTRS)
Ray, Ronald J.
1990-01-01
In support of performance testing of the X-29A aircraft at the NASA-Ames, various thrust calculation techniques were developed and evaluated for use on the F404-GE-400 engine. The engine was thrust calibrated at NASA-Lewis. Results from these tests were used to correct the manufacturer's in-flight thrust program to more accurately calculate thrust for the specific test engine. Data from these tests were also used to develop an independent, simplified thrust calculation technique for real-time thrust calculation. Comparisons were also made to thrust values predicted by the engine specification model. Results indicate uninstalled gross thrust accuracies on the order of 1 to 4 percent for the various in-flight thrust methods. The various thrust calculations are described and their usage, uncertainty, and measured accuracies are explained. In addition, the advantages of a real-time thrust algorithm for flight test use and the importance of an accurate thrust calculation to the aircraft performance analysis are described. Finally, actual data obtained from flight test are presented.
The cobas® 6800/8800 System: a new era of automation in molecular diagnostics.
Cobb, Bryan; Simon, Christian O; Stramer, Susan L; Body, Barbara; Mitchell, P Shawn; Reisch, Natasa; Stevens, Wendy; Carmona, Sergio; Katz, Louis; Will, Stephen; Liesenfeld, Oliver
2017-02-01
Molecular diagnostics is a key component of laboratory medicine. Here, the authors review key triggers of ever-increasing automation in nucleic acid amplification testing (NAAT) with a focus on specific automated Polymerase Chain Reaction (PCR) testing and platforms such as the recently launched cobas® 6800 and cobas® 8800 Systems. The benefits of such automation for different stakeholders including patients, clinicians, laboratory personnel, hospital administrators, payers, and manufacturers are described. Areas Covered: The authors describe how molecular diagnostics has achieved total laboratory automation over time, rivaling clinical chemistry to significantly improve testing efficiency. Finally, the authors discuss how advances in automation decrease the development time for new tests enabling clinicians to more readily provide test results. Expert Commentary: The advancements described enable complete diagnostic solutions whereby specific test results can be combined with relevant patient data sets to allow healthcare providers to deliver comprehensive clinical recommendations in multiple fields ranging from infectious disease to outbreak management and blood safety solutions.
Environmentally safe aviation fuels
NASA Technical Reports Server (NTRS)
Liberio, Patricia D.
1995-01-01
In response to the Air Force directive to remove Ozone Depleting Chemicals (ODC's) from military specifications and Defense Logistics Agency's Hazardous Waste Minimization Program, we are faced with how to ensure a quality aviation fuel without using such chemicals. Many of these chemicals are found throughout the fuel and fuel related military specifications and are part of test methods that help qualify the properties and quality of the fuels before they are procured. Many years ago there was a directive for military specifications to use commercially standard test methods in order to provide standard testing in private industry and government. As a result the test methods used in military specifications are governed by the American Society of Testing and Materials (ASTM). The Air Force has been very proactive in the removal or replacement of the ODC's and hazardous materials in these test methods. For example, ASTM D3703 (Standard Test Method for Peroxide Number of Aviation Turbine Fuels), requires the use of Freon 113, a known ODC. A new rapid, portable hydroperoxide test for jet fuels similar to ASTM D3703 that does not require the use of ODC's has been developed. This test has proved, in limited testing, to be a viable substitute method for ASTM D3703. The Air Force is currently conducting a round robin to allow the method to be accepted by ASTM and therefore replace the current method. This paper will describe the Air Force's initiatives to remove ODC's and hazardous materials from the fuel and fuel related military specifications that the Air Force Wright Laboratory.
Ochodo, Eleanor A; Gopalakrishna, Gowri; Spek, Bea; Reitsma, Johannes B; van Lieshout, Lisette; Polman, Katja; Lamberton, Poppy; Bossuyt, Patrick M M; Leeflang, Mariska M G
2015-03-11
Point-of-care (POC) tests for diagnosing schistosomiasis include tests based on circulating antigen detection and urine reagent strip tests. If they had sufficient diagnostic accuracy they could replace conventional microscopy as they provide a quicker answer and are easier to use. To summarise the diagnostic accuracy of: a) urine reagent strip tests in detecting active Schistosoma haematobium infection, with microscopy as the reference standard; and b) circulating antigen tests for detecting active Schistosoma infection in geographical regions endemic for Schistosoma mansoni or S. haematobium or both, with microscopy as the reference standard. We searched the electronic databases MEDLINE, EMBASE, BIOSIS, MEDION, and Health Technology Assessment (HTA) without language restriction up to 30 June 2014. We included studies that used microscopy as the reference standard: for S. haematobium, microscopy of urine prepared by filtration, centrifugation, or sedimentation methods; and for S. mansoni, microscopy of stool by Kato-Katz thick smear. We included studies on participants residing in endemic areas only. Two review authors independently extracted data, assessed quality of the data using QUADAS-2, and performed meta-analysis where appropriate. Using the variability of test thresholds, we used the hierarchical summary receiver operating characteristic (HSROC) model for all eligible tests (except the circulating cathodic antigen (CCA) POC for S. mansoni, where the bivariate random-effects model was more appropriate). We investigated heterogeneity, and carried out indirect comparisons where data were sufficient. Results for sensitivity and specificity are presented as percentages with 95% confidence intervals (CI). We included 90 studies; 88 from field settings in Africa. The median S. haematobium infection prevalence was 41% (range 1% to 89%) and 36% for S. mansoni (range 8% to 95%). Study design and conduct were poorly reported against current standards. Tests for S. haematobium Urine reagent test strips versus microscopyCompared to microscopy, the detection of microhaematuria on test strips had the highest sensitivity and specificity (sensitivity 75%, 95% CI 71% to 79%; specificity 87%, 95% CI 84% to 90%; 74 studies, 102,447 participants). For proteinuria, sensitivity was 61% and specificity was 82% (82,113 participants); and for leukocyturia, sensitivity was 58% and specificity 61% (1532 participants). However, the difference in overall test accuracy between the urine reagent strips for microhaematuria and proteinuria was not found to be different when we compared separate populations (P = 0.25), or when direct comparisons within the same individuals were performed (paired studies; P = 0.21).When tests were evaluated against the higher quality reference standard (when multiple samples were analysed), sensitivity was marginally lower for microhaematuria (71% vs 75%) and for proteinuria (49% vs 61%). The specificity of these tests was comparable. Antigen assayCompared to microscopy, the CCA test showed considerable heterogeneity; meta-analytic sensitivity estimate was 39%, 95% CI 6% to 73%; specificity 78%, 95% CI 55% to 100% (four studies, 901 participants). Tests for S. mansoni Compared to microscopy, the CCA test meta-analytic estimates for detecting S. mansoni at a single threshold of trace positive were: sensitivity 89% (95% CI 86% to 92%); and specificity 55% (95% CI 46% to 65%; 15 studies, 6091 participants) Against a higher quality reference standard, the sensitivity results were comparable (89% vs 88%) but specificity was higher (66% vs 55%). For the CAA test, sensitivity ranged from 47% to 94%, and specificity from 8% to 100% (4 studies, 1583 participants). Among the evaluated tests for S. haematobium infection, microhaematuria correctly detected the largest proportions of infections and non-infections identified by microscopy.The CCA POC test for S. mansoni detects a very large proportion of infections identified by microscopy, but it misclassifies a large proportion of microscopy negatives as positives in endemic areas with a moderate to high prevalence of infection, possibly because the test is potentially more sensitive than microscopy.
[Interpretation of false positive results of biochemical prenatal tests].
Sieroszewski, Piotr; Słowakiewicz, Katarzyna; Perenc, Małgorzata
2010-03-01
Modern, non-invasive prenatal diagnostics based on biochemical and ultrasonographic markers of fetal defects allows us to calculate the risk of fetal chromosomal aneuploidies with high sensitivity and specificity An introduction of biochemical, non-invasive prenatal tests turned out to result in frequent false positive results of these tests in cases when invasive diagnostics does not confirm fetal defects. However prospective analysis of these cases showed numerous complications in the third trimester of the pregnancies.
Design certification tests: High Pressure Oxygen Filter (HPOF) program. Summary report
NASA Technical Reports Server (NTRS)
Smith, I. D.
1976-01-01
Design and acceptance certification test procedures and results are presented for a high pressure oxygen filter developed to protect the sealing surfaces in emergency oxygen systems. Equipment specifications are included.
Xiao, Xiang; Wang, Tianping; Ye, Hongzhuan; Qiang, Guangxiang; Wei, Haiming; Tian, Zhigang
2005-01-01
OBJECTIVE: To determine the validity of a recently developed rapid test--a colloidal dye immunofiltration assay (CDIFA)--used by health workers in field settings to identify villagers infected with Schistosoma japonicum. METHODS: Health workers in the field used CDIFA to test samples from 1553 villagers in two areas of low endemicity and an area where S. japonicum was not endemic in Anhui, China. All the samples were then tested in the laboratory by laboratory staff using a standard parasitological method (Kato-Katz), an indirect haemagglutination assay (IHA), and CDIFA. The results of CDIFA performed by health workers were compared with those obtained by Kato-Katz and IHA. FINDINGS: Concordance between the results of CDIFA performed in field settings and in the laboratory was high (kappa index, 0.95; 95% confidence interval, 0.93-0.97). When Kato-Katz was used as the reference test, the overall sensitivity and specificity of CDIFA were 98.5% and 83.6%, respectively in the two villages in areas of low endemicity, while the specificity was 99.8% in the nonendemic village. Compared with IHA, the overall specificity and sensitivity of CDIFA were greater than 99% and 96%, respectively. With the combination of Kato-Katz and IHA as the reference standard, CDIFA had a sensitivity of 95.8% and a specificity of 99.5%, and an accuracy of 98.6% in the two areas of low endemicity. CONCLUSION: CDIFA is a specific, sensitive, and reliable test that can be used for rapid screening for schistosomiasis by health workers in field settings. PMID:16175827
Lipkus, Isaac M; Samsa, Gregory P; Dement, John; Skinner, Celette Sugg; Green, La Sonya G; Pompeii, Lisa; Ransohoff, David F
2003-11-01
Inaccuracy in self-reports of colorectal cancer (CRC) screening procedures (e.g., over- or underreporting) may interfere with individuals adhering to appropriate screening intervals, and can blur the true effects of physician recommendations to screen and the effects of interventions designed to promote screening. We assessed accuracy of self-report of having a fecal occult blood test (FOBT) within a 1-year window based on receipt of FOBT kits among individuals aged 50 and older in the carpentry trade (N = 658) who were off-schedule for having had a FOBT. Indices of evaluating accuracy of self-reports (concordance, specificity, false-positive and false-negative rates) were calculated relative to receipt of a mailed FOBT. Among those who mailed a completed FOBT, we assessed accuracy of reporting the test result. Participants underestimated having performed a FOBT (false-negative rate of 44%). Accuracy was unrelated to perceptions of getting or worrying about CRC or family history. Self-reports of having a negative FOBT result more consistently matched the laboratory result (specificity 98%) than having a positive test result (sensitivity 63%). Contrary to other findings, participants under- rather than over reported FOBT screening. Results suggest greater efforts are needed to enhance accurate recall of FOBT screening.
Jírová, D; Kejlová, K; Brabec, M; Bendová, H; Kolárová, H
2003-01-01
We have introduced the 3T3 NRU cytotoxicity test for methodological, economical and ethical reasons as a regular part of tier pre-marketing testing to assess local tolerance of raw materials for cosmetics, household chemicals and final cosmetic products. Using the 3T3 cell line according to the standard INVITTOX protocol No.64 (NRU Assay) the borderline concentration, relevant to the highest tolerated dose, is determined for each material. The toxic effect is reached at different concentration levels specific for individual cosmetics categories, depending on their chemical characteristics. Typical ranges of cytotoxicity for specific categories of cosmetics were established after testing of hundreds of materials. The range lies between 1 microg/ml (anti-dandruff shampoos), up to 2000 microg/ml (toothpastes and mouthwashes). The 3T3 NRU cytotoxicity test is a sensitive tool able to identify more aggressive products, that are also more likely to evoke irritation in human skin. It was even possible to detect protective effects of one natural herbal ingredient. The comparative study of cytotoxicity test results and human patch test results from a group of essential oils is presented. Cytotoxicity tests represent a highly ethical approach for estimation of irritancy. On the basis of in vitro test results suggesting low risk we can proceed to confirmatory tests in human volunteers.
Bias in estimating accuracy of a binary screening test with differential disease verification
Brinton, John T.; Ringham, Brandy M.; Glueck, Deborah H.
2011-01-01
SUMMARY Sensitivity, specificity, positive and negative predictive value are typically used to quantify the accuracy of a binary screening test. In some studies it may not be ethical or feasible to obtain definitive disease ascertainment for all subjects using a gold standard test. When a gold standard test cannot be used an imperfect reference test that is less than 100% sensitive and specific may be used instead. In breast cancer screening, for example, follow-up for cancer diagnosis is used as an imperfect reference test for women where it is not possible to obtain gold standard results. This incomplete ascertainment of true disease, or differential disease verification, can result in biased estimates of accuracy. In this paper, we derive the apparent accuracy values for studies subject to differential verification. We determine how the bias is affected by the accuracy of the imperfect reference test, the percent who receive the imperfect reference standard test not receiving the gold standard, the prevalence of the disease, and the correlation between the results for the screening test and the imperfect reference test. It is shown that designs with differential disease verification can yield biased estimates of accuracy. Estimates of sensitivity in cancer screening trials may be substantially biased. However, careful design decisions, including selection of the imperfect reference test, can help to minimize bias. A hypothetical breast cancer screening study is used to illustrate the problem. PMID:21495059
Zhang, Xiaomei; Zhou, Tingting; Yu, Wenjing; Ai, Jinxia; Wang, Xuesong; Gao, Lijun; Yuan, Guangxin; Li, Mingcheng
2018-01-01
We developed a kind of Zaocys dhumnades DNA test kit and it's indexes including specificity, sensitivity and stability were evaluated and compared with the method recorded in Chinese Pharmacopoeia (2010 edition). The bioinformatics technology was used to design primers, sequencing and blast, in conjunction with PCR technology based on the characteristics of Z. dhumnades cytochrome b (Cyt b) gene. The efficiency of nucleic acid extraction by the kit was done in accordance with Pharmacopoeia method. The kit stability results proved effective after repeated freezing and thawing 20 times. The sensitivity results indicated that the lowest amount detected by the kit was 0. 025 g of each specimen. The specificity test of the kit was 100% specific. All repeatability tests indicated the same results when conducted three times. Compared with the method recorded in Chinese Pharmacopoeia, the PCR-based assay kit by our team developed is accurate, effective in identification of Z. dhumnades, it is simple and fast, demonstrating a broad prospect in quality inspection of Z. dhumnades in the future.
The role of orbital ultrasonography in distinguishing papilledema from pseudopapilledema
Carter, S B; Pistilli, M; Livingston, K G; Gold, D R; Volpe, N J; Shindler, K S; Liu, G T; Tamhankar, M A
2014-01-01
Purpose To determine the sensitivity and specificity of orbital ultrasonography in distinguishing papilledema from pseudopapilledema in adult patients. Methods The records of all adult patients referred to the neuro-ophthalmology service who underwent orbital ultrasonography for the evaluation of suspected papilledema were reviewed. The details of history, ophthalmologic examination, and results of ancillary testing including orbital ultrasonography, MRI, and lumbar puncture were recorded. Results of orbital ultrasonography were correlated with the final diagnosis of papilledema or pseudopapilledema on the basis of the clinical impression of the neuro-ophthalmologist. Ultrasound was considered positive when the optic nerve sheath diameter was ≥3.3 mm along with a positive 30° test. Results The sensitivity of orbital ultrasonography for detection of papilledema was 90% (CI: 80.2–99.3%) and the specificity in detecting pseudopapilledema was 79% (CI: 67.7–90.7%). Conclusions Orbital ultrasonography is a rapid and noninvasive test that is highly sensitive, but less specific in differentiating papilledema from pseudopapilledema in adult patients, and can be useful in guiding further management of patients in whom the diagnosis is initially uncertain. PMID:25190532
Umemura, Atsushi; Oeda, Tomoko; Hayashi, Ryutaro; Tomita, Satoshi; Kohsaka, Masayuki; Yamamoto, Kenji; Sawada, Hideyuki
2013-01-01
It is often hard to differentiate Parkinson's disease (PD) and parkinsonian variant of multiple system atrophy (MSA-P), especially in the early stages. Cardiac sympathetic denervation and putaminal rarefaction are specific findings for PD and MSA-P, respectively. We investigated diagnostic accuracy of putaminal apparent diffusion coefficient (ADC) test for MSA-P and (123)I-metaiodobenzylguanidine (MIBG) scintigram for PD, especially in early-stage patients. The referral standard diagnosis of PD and MSA-P were the diagnostic criteria of the United Kingdom Parkinson's Disease Society Brain Bank Criteria and the second consensus criteria, respectively. Based on the referral standard criteria, diagnostic accuracy [area under the receiver-operator characteristic curve (AUC), sensitivity and specificity] of the ADC and MIBG tests was estimated retrospectively. Diagnostic accuracy of these tests performed within 3 years of symptom onset was also investigated. ADC and MIBG tests were performed on 138 patients (20 MSA and 118 PD). AUC was 0.95 and 0.83 for the ADC and MIBG tests, respectively. Sensitivity and specificity were 85.0% and 89.0% for MSA-P diagnosis by ADC test and 67.0% and 80.0% for PD diagnosis by MIBG test. When these tests were restricted to patients with disease duration ≤ 3 years, the sensitivity and specificity were 75.0% and 91.4% for the ADC test (MSA-P diagnosis) and 47.7% and 92.3% for the MIBG test (PD diagnosis). Both tests were useful in differentiating between PD and MSA-P, even in the early stages. In early-stage patients, elevated putaminal ADC was a diagnostic marker for MSA-P. Despite high specificity of the MIBG test, careful neurological history and examinations were required for PD diagnosis because of possible false-negative results.
Development and validation of the Perceived Game-Specific Soccer Competence Scale.
Forsman, Hannele; Gråstén, Arto; Blomqvist, Minna; Davids, Keith; Liukkonen, Jarmo; Konttinen, Niilo
2016-07-01
The objective of this study was to create a valid, self-reported, game-specific soccer competence scale. A structural model of perceived competence, performance measures and motivation was tested as the basis for the scale. A total of 1321 soccer players (261 females, 1060 males) ranging from 12 to 15 years (13.4 ± 1.0 years) participated in the study. They completed the Perceived Game-Specific Soccer Competence Scale (PGSSCS), self-assessments of tactical skills and motivation, as well as technical and speed and agility tests. Results of factor analyses, tests of internal consistency and correlations between PGSSCS subscales, performance measures and motivation supported the reliability and validity of the PGSSCS. The scale can be considered a suitable instrument to assess perceived game-specific competence among young soccer players.
Wu, Cheng-Ching; Lin, Hung-Yu; Wang, Chao-Ping; Lu, Li-Fen; Yu, Teng-Hung; Hung, Wei-Chin; Houng, Jer-Yiing; Chung, Fu-Mei; Lee, Yau-Jiunn; Hu, Jin-Jia
2015-11-03
Prostate cancer remains the most common cancer in men. Qualitative or semi-quantitative immunochromatographic measurements of prostate specific antigen (PSA) have been shown to be simple, noninvasive and feasible. The aim of this study was to evaluate an optimized gold immunochromatographic strip device for the detection of PSA, in which the results can be analysed using a Chromogenic Rapid Test Reader to quantitatively assess the test results. This reader measures the reflectance of the signal line via a charge-coupled device camera. For quantitative analysis, PSA concentration was computed via a calibration equation. Capillary blood samples from 305 men were evaluated, and two independent observers interpreted the test results after 12 min. Blood samples were also collected and tested with a conventional quantitative assay. Sensitivity, specificity, positive and negative predictive values, and accuracy of the PSA rapid quantitative test system were 100, 96.6, 89.5, 100, and 97.4 %, respectively. Reproducibility of the test was 99.2, and interobserver variation was 8 % with a false positive rate of 3.4 %. The correlation coefficient between the ordinary quantitative assay and the rapid quantitative test was 0.960. The PSA rapid quantitative test system provided results quickly and was easy to use, so that tests using this system can be easily performed at outpatient clinics or elsewhere. This system may also be useful for initial cancer screening and for point-of-care testing, because results can be obtained within 12 min and at a cost lower than that of conventional quantitative assays.
Sensitivity and specificity of eustachian tube function tests in adults.
Doyle, William J; Swarts, J Douglas; Banks, Julianne; Casselbrant, Margaretha L; Mandel, Ellen M; Alper, Cuneyt M
2013-07-01
The study demonstrates the utility of eustachian tube (ET) function (ETF) test results for accurately assigning ears to disease state. To determine if ETF tests can identify ears with physician-diagnosed ET dysfunction (ETD) in a mixed population at high sensitivity and specificity and to define the interrelatedness of ETF test parameters. Through use of the forced-response, inflation-deflation, Valsalva, and sniffing tests, ETF was evaluated in 15 control ears of adult subjects after unilateral myringotomy (group 1) and in 23 ears of 19 adult subjects with ventilation tubes inserted for ETD (group 2). Data were analyzed using logistic regression including each parameter independently and then a step-down discriminant analysis including all ETF test parameters to predict group assignment. Factor analysis operating over all parameters was used to explore relatedness. ETF testing. ETF parameters for the forced response, inflation-deflation, Valsalva, and sniffing tests measured in 15 control ears of adult subjects after unilateral myringotomy (group 1) and in 23 ears of 19 adult subjects with ventilation tubes inserted for ETD (group 2). The discriminant analysis identified 4 ETF test parameters (Valsalva, ET opening pressure, dilatory efficiency, and percentage of positive pressure equilibrated) that together correctly assigned ears to group 2 at a sensitivity of 95% and a specificity of 83%. Individual parameters representing the efficiency of ET opening during swallowing showed moderately accurate assignments of ears to their respective groups. Three factors captured approximately 98% of the variance among parameters: the first had negative loadings of the ETF structural parameters; the second had positive loadings of the muscle-assisted ET opening parameters; and the third had negative loadings of the muscle-assisted ET opening parameters and positive loadings of the structural parameters. These results show that ETF tests can correctly assign individual ears to physician-diagnosed ETD with high sensitivity and specificity and that ETF test parameters can be grouped into structural-functional categories.
Johnson, David A.; Barclay, Robert L.; Mergener, Klaus; Weiss, Gunter; König, Thomas; Beck, Jürgen; Potter, Nicholas T.
2014-01-01
Background Screening improves outcomes related to colorectal cancer (CRC); however, suboptimal participation for available screening tests limits the full benefits of screening. Non-invasive screening using a blood based assay may potentially help reach the unscreened population. Objective To compare the performance of a new Septin9 DNA methylation based blood test with a fecal immunochemical test (FIT) for CRC screening. Design: In this trial, fecal and blood samples were obtained from enrolled patients. To compare test sensitivity for CRC, patients with screening identified colorectal cancer (n = 102) were enrolled and provided samples prior to surgery. To compare test specificity patients were enrolled prospectively (n = 199) and provided samples prior to bowel preparation for screening colonoscopy. Measurements Plasma and fecal samples were analyzed using the Epi proColon and OC Fit-Check tests respectively. Results For all samples, sensitivity for CRC detection was 73.3% (95% CI 63.9–80.9%) and 68.0% (95% CI 58.2–76.5%) for Septin9 and FIT, respectively. Specificity of the Epi proColon test was 81.5% (95% CI 75.5–86.3%) compared with 97.4% (95% CI 94.1–98.9%) for FIT. For paired samples, the sensitivity of the Epi proColon test (72.2% –95% CI 62.5–80.1%) was shown to be statistically non-inferior to FIT (68.0%–95% CI 58.2–76.5%). When test results for Epi proColon and FIT were combined, CRC detection was 88.7% at a specificity of 78.8%. Conclusions At a sensitivity of 72%, the Epi proColon test is non- inferior to FIT for CRC detection, although at a lower specificity. With negative predictive values of 99.8%, both methods are identical in confirming the absence of CRC. Trial Registration ClinicalTrials.gov NCT01580540 PMID:24901436
Balasubramanian, Akhila; Kulasingam, Shalini L.; Baer, Atar; Hughes, James P.; Myers, Evan R.; Mao, Constance; Kiviat, Nancy B.; Koutsky, Laura A.
2010-01-01
Objective Estimate the accuracy and cost-effectiveness of cervical cancer screening strategies based on high-risk HPV DNA testing of self-collected vaginal samples. Materials and Methods A subset of 1,665 women (18-50 years of age) participating in a cervical cancer screening study were screened by liquid-based cytology and by high-risk HPV DNA testing of both self-collected vaginal swab samples and clinician-collected cervical samples. Women with positive/abnormal screening test results and a subset of women with negative screening test results were triaged to colposcopy. Based on individual and combined test results, five screening strategies were defined. Estimates of sensitivity and specificity for cervical intraepithelial neoplasia grade 2 or worse were calculated and a Markov model was used to estimate the incremental cost-effectiveness ratios (ICERs) for each strategy. Results Compared to cytology-based screening, high-risk HPV DNA testing of self-collected vaginal samples was more sensitive (68%, 95%CI=58%-78% versus 85%, 95%CI=76%-94%) but less specific (89%, 95%CI=86%-91% versus 73%, 95%CI=67%-79%). A strategy of high-risk HPV DNA testing of self-collected vaginal samples followed by cytology triage of HPV positive women, was comparably sensitive (75%, 95%CI=64%-86%) and specific (88%, 95%CI=85%-92%) to cytology-based screening. In-home self-collection for high-risk HPV DNA detection followed by in-clinic cytology triage had a slightly lower lifetime cost and a slightly higher quality-adjusted life expectancy than did cytology-based screening (ICER of triennial screening compared to no screening was $9,871/QALY and $12,878/QALY, respectively). Conclusions Triennial screening by high-risk HPV DNA testing of in-home, self-collected vaginal samples followed by in-clinic cytology triage was cost-effective. PMID:20592553
Guidelines for Standardized Testing of Broadband Seismometers and Accelerometers
Hutt, Charles R.; Evans, John R.; Followill, Fred; Nigbor, Robert L.; Wielandt, Erhard
2010-01-01
Testing and specification of seismic and earthquake-engineering sensors and recorders has been marked by significant variations in procedures and selected parameters. These variations cause difficulty in comparing such specifications and test results. In July 1989, and again in May 2005, the U.S. Geological Survey hosted international pub-lic/private workshops with the goal of defining widely accepted guidelines for the testing of seismological inertial sensors, seismometers, and accelerometers. The Proceedings of the 2005 workshop have been published and include as appendix 6 the report of the 1989 workshop. This document represents a collation and rationalization of a single set of formal guidelines for testing and specifying broadband seismometers and accelerometers.
Röhrich, J; Zörntlein, S; Becker, J; Urban, R
2010-04-01
The Rapid Stat assay, a point-of-collection drug-testing device for detection of amphetamines, cannabinoids, cocaine, opiates, methadone, and benzodiazepines in oral fluid, was evaluated for cannabis and amphetamine-type stimulants. The Rapid Stat tests (n = 134) were applied by police officers in routine traffic checks. Oral fluid and blood samples were analyzed using gas chromatography-mass spectrometry (GC-MS) for Delta(9)-tetrahydrocannabinol, amphetamine, methamphetamine, methylenedioxymethamphetamine, methylenedioxyethylamphetamine, and methylenedioxyamphetamine. The comparison of GC-MS analysis of oral fluid with the Rapid Stat results for cannabis showed a sensitivity of 85%, a specificity of 87%, and a total confirmation rate of 87%. When compared with serum, the sensitivity of the cannabis assay decreased to 71%, the specificity to 60%, and the total confirmation rate to 66%. These findings were possibly caused by an incorrect reading of the THC test results. Comparison of the Rapid Stat amphetamine assay with GC-MS in oral fluid showed a sensitivity of 94%, a specificity of 97%, and a total confirmation rate of 97%. Compared with serum, a sensitivity of 100%, a specificity of 90%, and a total confirmation rate of 92% was found. The amphetamine assay must, therefore, be regarded as satisfactory.
Kesli, Recep; Polat, Hakki; Terzi, Yuksel; Kurtoglu, Muhammet Guzel; Uyar, Yavuz
2011-12-01
Hepatitis C virus (HCV) is a global health care problem. Diagnosis of HCV infection is mainly based on the detection of anti-HCV antibodies as a screening test with serum samples. Recombinant immunoblot assays are used as supplemental tests and for the final detection and quantification of HCV RNA in confirmatory tests. In this study, we aimed to compare the HCV core antigen test with the HCV RNA assay for confirming anti-HCV results to determine whether the HCV core antigen test may be used as an alternative confirmatory test to the HCV RNA test and to assess the diagnostic values of the total HCV core antigen test by determining the diagnostic specificity and sensitivity rates compared with the HCV RNA test. Sera from a total of 212 treatment-naive patients were analyzed for anti-HCV and HCV core antigen both with the Abbott Architect test and with the molecular HCV RNA assay consisting of a reverse transcription-PCR method as a confirmatory test. The diagnostic sensitivity, specificity, and positive and negative predictive values of the HCV core antigen assay compared to the HCV RNA test were 96.3%, 100%, 100%, and 89.7%, respectively. The levels of HCV core antigen showed a good correlation with those from the HCV RNA quantification (r = 0.907). In conclusion, the Architect HCV antigen assay is highly specific, sensitive, reliable, easy to perform, reproducible, cost-effective, and applicable as a screening, supplemental, and preconfirmatory test for anti-HCV assays used in laboratory procedures for the diagnosis of hepatitis C virus infection.
On the Use of a Test to Exhaustion Specific to Tennis (TEST) with Ball Hitting by Elite Players
2016-01-01
Purpose We aimed to a) introduce a new Test to Exhaustion Specific to Tennis (TEST) and compare performance (test duration) and physiological responses to those obtained during the 20-m multistage shuttle test (MSST), and b) determine to which extent those variables correlate with performance level (tennis competitive ranking) for both test procedures. Methods Twenty-seven junior players (8 males, 19 females) members of the national teams of the French Tennis Federation completed MSST and TEST, including elements of the game (ball hitting, intermittent activity, lateral displacement), in a randomized order. Cardiorespiratory responses were compared at submaximal (respiratory compensation point) and maximal loads between the two tests. Results At the respiratory compensation point oxygen uptake (50.1 ± 4.7 vs. 47.5 ± 4.3 mL.min-1.kg-1, p = 0.02), but not minute ventilation and heart rate, was higher for TEST compared to MSST. However, load increment and physiological responses at exhaustion did not differ between the two tests. Players’ ranking correlated negatively with oxygen uptake measured at submaximal and maximal loads for both TEST (r = -0.41; p = 0.01 and -0.55; p = 0.004) and MSST (r = -0.38; P = 0.05 and -0.51; p = 0.1). Conclusion Using TEST provides a tennis-specific assessment of aerobic fitness and may be used to prescribe aerobic exercise in a context more appropriate to the game than MSST. Results also indicate that VO2 values both at submaximal and maximal load reached during TEST and MSST are moderate predictors of players competitive ranking. PMID:27035342
NASA Astrophysics Data System (ADS)
Ishizawa, Y.; Abe, K.; Shirako, G.; Takai, T.; Kato, H.
The electromagnetic compatibility (EMC) control method, system EMC analysis method, and system test method which have been applied to test the components of the MOS-1 satellite are described. The merits and demerits of the problem solving, specification, and system approaches to EMC control are summarized, and the data requirements of the SEMCAP (specification and electromagnetic compatibility analysis program) computer program for verifying the EMI safety margin of the components are sumamrized. Examples of EMC design are mentioned, and the EMC design process and selection method for EMC critical points are shown along with sample EMC test results.
Garcia-Fernandez, Juan; Garcia-Molina, Alberto; Aparicio-Lopez, Celeste; Sanchez-Carrion, Rocío; Ensenat, Antònia; Pena-Casanova, Jordi; Roig-Rovira, Teresa
2015-12-16
Tham and Tegner proposed the Baking Tray Task (BTT) as a fast simple assessment test for detecting spatial negligence. However, very few studies have examined its validity as a diagnostic test. To analyse the diagnostic validity of the BTT by measuring its specificity and sensitivity in a sample of subjects with right hemisphere strokes. Forty-eight patients with right hemisphere vascular lesions were distributed in two groups (negligence group, n = 35; non-negligence group, n = 13) according to the scores obtained in a battery of visuospatial examination tests. The participants' performance on the BTT was compared with that of a healthy control group (n = 12). The results showed a high level of sensitivity of the BTT, but low specificity. The performance on the BTT of eight of the 13 members of the non-negligence group was suggestive of negligence. The BTT has proved to be a sensitive test for the detection of spatial negligence. Yet, based on its low specificity, its use alone as a single diagnostic test is not recommended.
Pote, Kiran; Narang, Rahul; Deshmukh, Pradeep
2018-01-01
Differentiating scrub typhus from other acute febrile illness is difficult due to non specificity of clinical symptoms and relative absence of eschar in Indian population. The diagnosis thus relies mainly on laboratory tests. Antibody based serological tests are mainstay of scrub typhus diagnosis. Here, we evaluated the diagnostic performance of IgM ELISA, IgM IFA and ICT to detect antibodies against O. tsutsugamushi in acute serum of febrile patients. The serum samples from 600 randomly selected patients suffering from acute undifferentiated fever were tested by all the three tests mentioned above. We used latent class analysis to generate unbiased results as all the tests for scrub typhus diagnosis are imperfect and none of them can be considered as reference standard. We found that IgM ELISA with cutoff titer 0.5 OD has high diagnostic accuracy (sensitivity 99.9% and specificity 99.15) than IgM IFA (sensitivity 96.8% and specificity 99.7%) for scrub typhus diagnosis. ICT used in our study had very high specificity 100% but low sensitivity (38%) which would limit its use for acute serum samples. ICT being a screening or point of care test, has to be more sensitive while some compromise with specificity is affordable. Hence, optimal cutoff for ICT should be evaluated under different settings. IgM ELISA being simple and affordable could be an alternative diagnostic test to IgM IFA which is subjective and costly.
... of a blood clotting or bleeding disorder Normal Results PT is measured in seconds. Most of the ... meaning of your specific test results. What Abnormal Results Mean If you are not taking blood thinning ...
An approach to operating system testing
NASA Technical Reports Server (NTRS)
Sum, R. N., Jr.; Campbell, R. H.; Kubitz, W. J.
1984-01-01
To ensure the reliability and performance of a new system, it must be verified or validated in some manner. Currently, testing is the only resonable technique available for doing this. Part of this testing process is the high level system test. System testing is considered with respect to operating systems and in particular UNIX. This consideration results in the development and presentation of a good method for performing the system test. The method includes derivations from the system specifications and ideas for management of the system testing project. Results of applying the method to the IBM System/9000 XENIX operating system test and the development of a UNIX test suite are presented.
Encephalitozoon cuniculi antibodies in a specific-pathogen-free rabbit unit.
Bywater, J E; Kellett, B S
1978-01-01
We describe our discovery of Encephalitozoon cuniculi antibodies in a specific-pathogen-free rabbit colony. Small-sized samples had failed to reveal the presence of infection with a prevalence of about 5%. Using an India ink immunoreaction test by which we were able to visualize both negative and positive reactions, we were able to undertake a 100% screen of the colony of more than 700 rabbits and to repeat this 4 weeks later when we had culled the positive reactors. By collating the results of those tests with the results of tests on previously collected samples, we have been able to discuss and observe age and sex susceptibilities and the mode of transmission of the naturally occurring disease. PMID:151081
A comparative study of internally and externally capped balloons using small scale test balloons
NASA Technical Reports Server (NTRS)
Bell, Douglas P.
1994-01-01
Caps have been used to structurally reinforce scientific research balloons since the late 1950's. The scientific research balloons used by the National Aeronautics and Space Administration (NASA) use internal caps. A NASA cap placement specification does not exist since no empirical information exisits concerning cap placement. To develop a cap placement specification, NASA has completed two in-hangar inflation tests comparing the structural contributions of internal caps and external caps. The tests used small scale test balloons designed to develop the highest possible stresses within the constraints of the hangar and balloon materials. An externally capped test balloon and an internally capped test balloon were designed, built, inflated and simulated to determine the structural contributions and benefits of each. The results of the tests and simulations are presented.
Yang, Mingjuan; Ke, Yuehua; Wang, Xuesong; Ren, Hang; Liu, Wei; Lu, Huijun; Zhang, Wenyi; Liu, Shiwei; Chang, Guohui; Tian, Shuguang; Wang, Lihua; Huang, Liuyu; Liu, Chao; Yang, Ruifu; Chen, Zeliang
2016-06-01
Confirming Ebola virus disease (EVD), a deadly infectious disease, requires real-time RT-PCR, which takes up to a few hours to yield results. Therefore, a rapid diagnostic assay is imperative for EVD diagnosis. A rapid nucleic acid test based on recombinase polymerase amplification (EBOV-RPA) was developed to specifically detect the 2014 outbreak strains. The EBOV-RPA assay was evaluated by testing samples from suspected EVD patients in parallel with RT-PCR. An EBOV-RPA, which could be completed in 20 min, was successfully developed. Of 271 patients who tested positive for Ebola virus by RT-PCR, 264 (sensitivity: 97%, 95% CI: 95.5-99.3%) were positive by EBOV-RPA; 101 of 104 patients (specificity: 97%, 95% CI: 93.9-100%) who tested negative by RT-PCR were also negative by EBOV-RPA. The sensitivity values for samples with a Ct value of <34, which accounted for 95.59% of the samples, was 100%. Discordant samples positive by RT-PCR but negative by EBOV-RPA had significantly high Ct values. Results of external quality assessment samples with EBOV-RPA were 100%, consistent with those of RT-PCR. The EBOV-RPA assay showed 97% sensitivity and 97% specificity for all EVD samples tested, making it a rapid and sensitive test for EVD diagnosis.
Plumb, Andrew A; Halligan, Steve; Pendsé, Douglas A; Taylor, Stuart A; Mallett, Susan
2014-05-01
CT colonography (CTC) is recommended after positive faecal occult blood testing (FOBt) when colonoscopy is incomplete or infeasible. We aimed to estimate the sensitivity and specificity of CTC for colorectal cancer and adenomatous polyps following positive FOBt via systematic review. The MEDLINE, EMBASE, AMED and Cochrane Library databases were searched for CTC studies reporting sensitivity and specificity for colorectal cancer and adenomatous polyps. Included subjects had tested FOBt-positive by guaiac or immunochemical methods. Per-patient detection rates were summarized via forest plots. Meta-analysis of sensitivity and specificity was conducted using a bivariate random effects model and the average operating point calculated. Of 538 articles considered, 5 met inclusion criteria, describing results from 622 patients. Research study quality was good. CTC had a high per-patient average sensitivity of 88.8 % (95 % CI 83.6 to 92.5 %) for ≥6 mm adenomas or colorectal cancer, with low between-study heterogeneity. Specificity was both more heterogeneous and lower, at an average of 75.4 % (95 % CI 58.6 to 86.8 %). Few studies have investigated CTC in FOBt-positive individuals. CTC is sensitive at a ≥6 mm threshold but specificity is lower and variable. Despite the limited data, these results suggest that CTC may adequately substitute for colonoscopy when the latter is undesirable. • FOBt is the most common mass screening test for colorectal cancer. • Few studies evaluate CT colonography after positive FOBt. • CTC is approximately 89 % sensitive for ≥6 mm adenomas/cancer in this setting. • Specificity is lower, at approximately 75 %, and more variable. • CT colonography is a good alternative when colonoscopy is undesirable.
Genetic and Environmental Architecture of Changes in Episodic Memory from Middle to Late Middle Age
Panizzon, Matthew S.; Neale, Michael C.; Docherty, Anna R.; Franz, Carol E.; Jacobson, Kristen C.; Toomey, Rosemary; Xian, Hong; Vasilopoulos, Terrie; Rana, Brinda K.; McKenzie, Ruth M.; Lyons, Michael J.; Kremen, William S.
2015-01-01
Episodic memory is a complex construct at both the phenotypic and genetic level. Ample evidence supports age-related cognitive stability and change being accounted for by general and domain-specific factors. We hypothesized that general and specific factors would underlie change even within this single cognitive domain. We examined six measures from three episodic memory tests in a narrow age cohort at middle and late middle age. The factor structure was invariant across occasions. At both timepoints two of three test-specific factors (story recall, design recall) had significant genetic influences independent of the general memory factor. Phenotypic stability was moderate to high, and primarily accounted for by genetic influences, except for one test-specific factor (list learning). Mean change over time was nonsignificant for one test-level factor; one declined; one improved. The results highlight the phenotypic and genetic complexity of memory and memory change, and shed light on an understudied period of life. PMID:25938244
Application of the Bootstrap Statistical Method in Deriving Vibroacoustic Specifications
NASA Technical Reports Server (NTRS)
Hughes, William O.; Paez, Thomas L.
2006-01-01
This paper discusses the Bootstrap Method for specification of vibroacoustic test specifications. Vibroacoustic test specifications are necessary to properly accept or qualify a spacecraft and its components for the expected acoustic, random vibration and shock environments seen on an expendable launch vehicle. Traditionally, NASA and the U.S. Air Force have employed methods of Normal Tolerance Limits to derive these test levels based upon the amount of data available, and the probability and confidence levels desired. The Normal Tolerance Limit method contains inherent assumptions about the distribution of the data. The Bootstrap is a distribution-free statistical subsampling method which uses the measured data themselves to establish estimates of statistical measures of random sources. This is achieved through the computation of large numbers of Bootstrap replicates of a data measure of interest and the use of these replicates to derive test levels consistent with the probability and confidence desired. The comparison of the results of these two methods is illustrated via an example utilizing actual spacecraft vibroacoustic data.
Genetic and environmental architecture of changes in episodic memory from middle to late middle age.
Panizzon, Matthew S; Neale, Michael C; Docherty, Anna R; Franz, Carol E; Jacobson, Kristen C; Toomey, Rosemary; Xian, Hong; Vasilopoulos, Terrie; Rana, Brinda K; McKenzie, Ruth; Lyons, Michael J; Kremen, William S
2015-06-01
Episodic memory is a complex construct at both the phenotypic and genetic level. Ample evidence supports age-related cognitive stability and change being accounted for by general and domain-specific factors. We hypothesized that general and specific factors would underlie change even within this single cognitive domain. We examined 6 measures from 3 episodic memory tests in a narrow age cohort at middle and late middle age. The factor structure was invariant across occasions. At both timepoints 2 of 3 test-specific factors (story recall, design recall) had significant genetic influences independent of the general memory factor. Phenotypic stability was moderate to high, and primarily accounted for by genetic influences, except for 1 test-specific factor (list learning). Mean change over time was nonsignificant for 1 test-level factor; 1 declined; 1 improved. The results highlight the phenotypic and genetic complexity of memory and memory change, and shed light on an understudied period of life. (c) 2015 APA, all rights reserved.
Suri, Pradeep; Rainville, James; Katz, Jeffrey N.; Jouve, Cristin; Hartigan, Carol; Limke, Janet; Pena, Enrique; Li, Ling; Swaim, Bryan; Hunter, David J
2010-01-01
Study Design Cross-sectional study with prospective recruitment. Objective To determine the accuracy of the physical examination for the diagnosis of midlumbar nerve root impingement (L2, L3, or L4), low lumbar nerve root impingement (L5 or S1) and level-specific lumbar nerve root impingement on magnetic resonance imaging (MRI), using individual tests and combinations of tests. Summary of Background Data The sensitivity and specificity of the physical examination for the localization of nerve root impingement has not been previously studied. Methods Sensitivities, specificities and LRs were calculated for the ability of individual tests and test combinations to predict the presence or absence of nerve root impingement at midlumbar, low lumbar, and specific nerve root levels. Results LRs ≥5.0 indicate moderate to large changes from pre-test probability of nerve root impingement to post-test probability. For the diagnosis of midlumbar impingement, the femoral stretch test (FST), crossed femoral stretch test (CFST), medial ankle pinprick sensation, and patellar reflex testing demonstrated LRs ≥5.0 (LR ∞). LRs ≥5.0 were seen with the combinations of FST and either patellar reflex testing (LR 7.0; 95% CI 2.3–21), or the sit-to-stand test (LR ∞). For the diagnosis of low lumbar impingement, the Achilles reflex test demonstrated a LR ≥5.0 (LR 7.1; CI 0.96–53); test combinations did not increase LRs. For the diagnosis of level-specific impingement, LRs ≥5.0 were seen for anterior thigh sensation at L2 (LR 13; 95% CI 1.8–87); FST at L3 (LR 5.7 ; 95% CI 2.3–4.4); patellar reflex testing (LR 7.7; 95% CI 1.7–35), medial ankle sensation (LR ∞), or CFST (LR 13; 95% CI 1.8–87) at L4; and hip abductor strength at L5(LR 11; 95% CI 1.3–84). Test combinations increased LRs for level-specific root impingement at the L4 level only. Conclusions Individual physical examination tests may provide clinical information which substantially alters the likelihood that midlumbar impingement, low lumbar impingement, or level-specific impingement is present. Test combinations improve diagnostic accuracy for midlumbar impingement. PMID:20543768
Battery and cell testing at NASA. Marshall Space Flight Center
NASA Technical Reports Server (NTRS)
Whitt, Tom; Jackson, Lorna
1992-01-01
An overview covering the ten cell/battery tests ongoing at MSFC are presented. The presentation is not intended to give specific test results on any test. The purpose and related program that applies to each test is acknowledged. Except for the Combined Release and Radiation Effects Satellite (CRRES), all are energy-stored and retrieval devices at low earth orbit (LEO) cycles.
ERIC Educational Resources Information Center
Sawaki, Yasuyo; Koizumi, Rie
2017-01-01
This small-scale qualitative study considers feedback and results reported for two major large-scale English language tests administered in Japan: the Global Test of English Communication for Students (GTECfS) and the Eiken Test in Practical English Proficiency (Eiken). Specifically, it examines current score-reporting practices in student and…
Cytology versus HPV testing for cervical cancer screening in the general population.
Koliopoulos, George; Nyaga, Victoria N; Santesso, Nancy; Bryant, Andrew; Martin-Hirsch, Pierre Pl; Mustafa, Reem A; Schünemann, Holger; Paraskevaidis, Evangelos; Arbyn, Marc
2017-08-10
Cervical cancer screening has traditionally been based on cervical cytology. Given the aetiological relationship between human papillomavirus (HPV) infection and cervical carcinogenesis, HPV testing has been proposed as an alternative screening test. To determine the diagnostic accuracy of HPV testing for detecting histologically confirmed cervical intraepithelial neoplasias (CIN) of grade 2 or worse (CIN 2+), including adenocarcinoma in situ, in women participating in primary cervical cancer screening; and how it compares to the accuracy of cytological testing (liquid-based and conventional) at various thresholds. We performed a systematic literature search of articles in MEDLINE and Embase (1992 to November 2015) containing quantitative data and handsearched the reference lists of retrieved articles. We included comparative test accuracy studies if all women received both HPV testing and cervical cytology followed by verification of the disease status with the reference standard, if positive for at least one screening test. The studies had to include women participating in a cervical cancer screening programme who were not being followed up for previous cytological abnormalities. We completed a 2 x 2 table with the number of true positives (TP), false positives (FP), true negatives (TN), and false negatives for each screening test (HPV test and cytology) used in each study. We calculated the absolute and relative sensitivities and the specificities of the tests for the detection of CIN 2+ and CIN 3+ at various thresholds and computed sensitivity (TP/(TP + TN) and specificity (TN/ (TN + FP) for each test separately. Relative sensitivity and specificity of one test compared to another test were defined as sensitivity of test-1 over sensitivity of test-2 and specificity of test-1 over specificity of test-2, respectively. To assess bias in the studies, we used the Quality Assessment of Diagnostic test Accuracy Studies (QUADAS) tool. We used a bivariate random-effects model for computing pooled accuracy estimates. This model takes into account the within- and between-study variability and the intrinsic correlation between sensitivity and specificity. We included a total of 40 studies in the review, with more than 140,000 women aged between 20 and 70 years old. Many studies were at low risk of bias. There were a sufficient number of included studies with adequate methodology to perform the following test comparisons: hybrid capture 2 (HC2) (1 pg/mL threshold) versus conventional cytology (CC) (atypical squamous cells of undetermined significance (ASCUS)+ and low-grade squamous intraepithelial lesions (LSIL)+ thresholds) or liquid-based cytology (LBC) (ASCUS+ and LSIL+ thresholds), other high-risk HPV tests versus conventional cytology (ASCUS+ and LSIL+ thresholds) or LBC (ASCUS+ and LSIL+ thresholds). For CIN 2+, pooled sensitivity estimates for HC2, CC and LBC (ASCUS+) were 89.9%, 62.5% and 72.9%, respectively, and pooled specificity estimates were 89.9%, 96.6%, and 90.3%, respectively. The results did not differ by age of women (less than or greater than 30 years old), or in studies with verification bias. Accuracy of HC2 was, however, greater in European countries compared to other countries. The results for the sensitivity of the tests were heterogeneous ranging from 52% to 94% for LBC, and 61% to 100% for HC2. Overall, the quality of the evidence for the sensitivity of the tests was moderate, and high for the specificity.The relative sensitivity of HC2 versus CC for CIN 2+ was 1.52 (95% CI: 1.24 to 1.86) and the relative specificity 0.94 (95% CI: 0.92 to 0.96), and versus LBC for CIN 2+ was 1.18 (95% CI: 1.10 to 1.26) and the relative specificity 0.96 (95% CI: 0.95 to 0.97). The relative sensitivity of HC2 versus CC for CIN 3+ was 1.46 (95% CI: 1.12 to 1.91) and the relative specificity 0.95 (95% CI: 0.93 to 0.97). The relative sensitivity of HC2 versus LBC for CIN 3+ was 1.17 (95% CI: 1.07 to 1.28) and the relative specificity 0.96 (95% CI: 0.95 to 0.97). Whilst HPV tests are less likely to miss cases of CIN 2+ and CIN 3+, these tests do lead to more unnecessary referrals. However, a negative HPV test is more reassuring than a negative cytological test, as the cytological test has a greater chance of being falsely negative, which could lead to delays in receiving the appropriate treatment. Evidence from prospective longitudinal studies is needed to establish the relative clinical implications of these tests.
Worldwide dispersion and deposition of radionuclides produced in atmospheric tests.
Bennett, Burton G
2002-05-01
Radionuclides produced in atmospheric nuclear tests were widely dispersed in the global environment. From the many measurements of the concentrations in air and the deposition amounts, much was learned of atmospheric circulation and environmental processes. Based on these results and the reported fission and total yields of individual tests, it has been possible to devise an empirical model of the movement and residence times of particles in the various atmospheric regions. This model, applied to all atmospheric weapons tests, allows extensive calculations of air concentrations and deposition amounts for the entire range of radionuclides produced throughout the testing period. Especially for the shorter-lived fission radionuclides, for which measurement results at the time of the tests are less extensive, a more complete picture of levels and isotope ratios can be obtained, forming a basis for improved dose estimations. The contributions to worldwide fallout can be inferred from individual tests, from tests at specific sites, or by specific countries. Progress was also made in understanding the global hydrological and carbon cycles from the tritium and 14C measurements. A review of the global measurements and modeling results is presented in this paper. In the future, if injections of materials into the atmosphere occur, their anticipated motions and fates can be predicted from the knowledge gained from the fallout experience.
Yzquierdo, Sergio Luis; Lemus, Dihadenys; Echemendia, Miguel; Montoro, Ernesto; McNerney, Ruth; Martin, Anandi; Palomino, Juan Carlos
2006-01-01
Background Conventional methods for susceptibility testing require several months before results can be reported. However, rapid methods to determine drug susceptibility have been developed recently. Phage assay have been reported as a rapid useful tools for antimicrobial susceptibility testing. The aim of this study was to apply the Phage assay for rapid detection of resistance on Mycobacterium tuberculosis strains in Cuba. Methods Phage D29 assay was performed on 102 M. tuberculosis strains to detect rifampicin resistance. The results were compared with the proportion method (gold standard) to evaluate the sensitivity and specificity of Phage assay. Results Phage assay results were available in 2 days whereas Proportion Methods results were obtain in 42 days. A total of 44 strains were detected as rifampicin resistant by both methods. However, one strains deemed resistant by Proportion Methods was susceptible by Phage assay. The sensitivity and specificity of Phage assay were 97.8 % and 100% respectively. Conclusion Phage assay provides rapid and reliable results for susceptibility testing; it's easy to perform, requires no specialized equipment and is applicable to drug susceptibility testing in low income countries where tuberculosis is a major public health problem. PMID:16630356
Performance of an HRP-2 Rapid Diagnostic Test in Nigerian Children Less Than 5 Years of Age
Ajumobi, Olufemi; Sabitu, Kabir; Nguku, Patrick; Kwaga, Jacob; Ntadom, Godwin; Gitta, Sheba; Elizeus, Rutebemberwa; Oyibo, Wellington; Nsubuga, Peter; Maire, Mark; Poggensee, Gabriele
2015-01-01
The diagnostic performance of histidine-rich protein 2 (HRP-2)–based malaria rapid diagnostic test (RDT) was evaluated in a mesoendemic area for malaria, Kaduna, Nigeria. We compared RDT results with expert microscopy results of blood samples from 295 febrile children under 5 years. Overall, 11.9% (35/295) tested positive with RDT compared with 10.5% (31/295) by microscopy: sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 100%, 98.5%, 88.6%, and 100%, respectively. The RDT sensitivity was not affected by transmission season, parasite density, and age. Specificity and positive PV decreased slightly during the high-transmission season (97.5% and 83.3%). The RDT test positivity rates in the low- and high-transmission seasons were 9.4% and 13.5%, respectively. Overall, the test performance of this RDT was satisfactory. The findings of a low proportion of RDT false positives, no invalid and no false-negative results should validate the performance of RDTs in this context. PMID:25711608
NASA Astrophysics Data System (ADS)
Weingart, Robert
This thesis is about the validation of a computational fluid dynamics simulation of a ground vehicle by means of a low-budget coast-down test. The vehicle is built to the standards of the 2014 Formula SAE rules. It is equipped with large wings in the front and rear of the car; the vertical loads on the tires are measured by specifically calibrated shock potentiometers. The coast-down test was performed on a runway of a local airport and is used to determine vehicle specific coefficients such as drag, downforce, aerodynamic balance, and rolling resistance for different aerodynamic setups. The test results are then compared to the respective simulated results. The drag deviates about 5% from the simulated to the measured results. The downforce numbers show a deviation up to 18% respectively. Moreover, a sensitivity analysis of inlet velocities, ride heights, and pitch angles was performed with the help of the computational simulation.
Development flight tests of JetStar LFC leading-edge flight test experiment
NASA Technical Reports Server (NTRS)
Fisher, David F.; Fischer, Michael C.
1987-01-01
The overall objective of the flight tests on the JetStar aircraft was to demonstrate the effectiveness and reliability of laminar flow control under representative flight conditions. One specific objective was to obtain laminar flow on the JetStar leading-edge test articles for the design and off-design conditions. Another specific objective was to obtain operational experience on a Laminar Flow Control (LFC) leading-edge system in a simulated airline service. This included operational experience with cleaning requirements, the effect of clogging, possible foreign object damage, erosion, and the effects of ice particle and cloud encounters. Results are summarized.
Some attributes of a language for property-based testing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neagoe, Vicentiu; Bishop, Matt
Property-based testing is a testing technique that evaluates executions of a program. The method checks that specifications, called properties, hold throughout the execution of the program. TASpec is a language used to specify these properties. This paper compares some attributes of the language with the specification patterns used for model-checking languages, and then presents some descriptions of properties that can be used to detect common security flaws in programs. This report describes the results of a one year research project at the University of California, Davis, which was funded by a University Collaboration LDRD entitled ''Property-based Testing for Cyber Securitymore » Assurance''.« less
Measurable residual disease testing in acute myeloid leukaemia.
Hourigan, C S; Gale, R P; Gormley, N J; Ossenkoppele, G J; Walter, R B
2017-07-01
There is considerable interest in developing techniques to detect and/or quantify remaining leukaemia cells termed measurable or, less precisely, minimal residual disease (MRD) in persons with acute myeloid leukaemia (AML) in complete remission defined by cytomorphological criteria. An important reason for AML MRD-testing is the possibility of estimating the likelihood (and timing) of leukaemia relapse. A perfect MRD-test would precisely quantify leukaemia cells biologically able and likely to cause leukaemia relapse within a defined interval. AML is genetically diverse and there is currently no uniform approach to detecting such cells. Several technologies focused on immune phenotype or cytogenetic and/or molecular abnormalities have been developed, each with advantages and disadvantages. Many studies report a positive MRD-test at diverse time points during AML therapy identifies persons with a higher risk of leukaemia relapse compared with those with a negative MRD-test even after adjusting for other prognostic and predictive variables. No MRD-test in AML has perfect sensitivity and specificity for relapse prediction at the cohort- or subject levels and there are substantial rates of false-positive and -negative tests. Despite these limitations, correlations between MRD-test results and relapse risk have generated interest in MRD-test result-directed therapy interventions. However, convincing proof that a specific intervention will reduce relapse risk in persons with a positive MRD-test is lacking and needs testing in randomized trials. Routine clinical use of MRD-testing requires further refinements and standardization/harmonization of assay platforms and results reporting. Such data are needed to determine whether results of MRD-testing can be used as a surrogate end point in AML therapy trials. This could make drug-testing more efficient and accelerate regulatory approvals. Although MRD-testing in AML has advanced substantially, much remains to be done.
Cheng, Hong; Macaluso, Maurizio; Vermund, Sten H.; Hook, Edward W.
2001-01-01
Published estimates of the sensitivity and specificity of PCR and ligase chain reaction (LCR) for detecting Chlamydia trachomatis are potentially biased because of study design limitations (confirmation of test results was limited to subjects who were PCR or LCR positive but culture negative). Relative measures of test accuracy are less prone to bias in incomplete study designs. We estimated the relative sensitivity (RSN) and relative false-positive rate (RFP) for PCR and LCR versus cell culture among 1,138 asymptomatic men and evaluated the potential bias of RSN and RFP estimates. PCR and LCR testing in urine were compared to culture of urethral specimens. Discordant results (PCR or LCR positive, but culture negative) were confirmed by using a sequence including the other DNA amplification test, direct fluorescent antibody testing, and a DNA amplification test to detect chlamydial major outer membrane protein. The RSN estimates for PCR and LCR were 1.45 (95% confidence interval [CI] = 1.3 to 1.7) and 1.49 (95% CI = 1.3 to 1.7), respectively, indicating that both methods are more sensitive than culture. Very few false-positive results were found, indicating that the specificity levels of PCR, LCR, and culture are high. The potential bias in RSN and RFP estimates were <5 and <20%, respectively. The estimation of bias is based on the most likely and probably conservative parameter settings. If the sensitivity of culture is between 60 and 65%, then the true sensitivity of PCR and LCR is between 90 and 97%. Our findings indicate that PCR and LCR are significantly more sensitive than culture, while the three tests have similar specificities. PMID:11682509
Evaluation of a Turbidimetric β-d-Glucan Test for Detection of Pneumocystis jirovecii Pneumonia.
Dichtl, Karl; Seybold, Ulrich; Wagener, Johannes
2018-07-01
Currently, diagnosis of Pneumocystis jirovecii pneumonia (PJP) relies on analysis of lower respiratory specimens, either by microscopy or quantitative real-time PCR (qPCR). Thus, bronchoscopy is required, which is associated with increased risk of respiratory failure. We assessed the value of noninvasive serologic β-d-glucan (BDG) testing for laboratory diagnosis of PJP using a newly available turbidimetric assay. We identified 73 cases of PJP with positive qPCR results from lower respiratory specimens for Pneumocystis and serology samples dating from 1 week before to 4 weeks after qPCR. In addition, 25 sera from controls with suspected PJP but specimens negative for Pneumocystis by qPCR were identified. Sera were tested with a turbidimetric BDG assay (Fujifilm Wako Chemicals Europe GmbH, Neuss, Germany), using an 11-pg/ml cutoff. Sensitivity and specificity were calculated based on qPCR test results as a reference. The turbidimetric BDG assay identified 63/73 patients with positive or slightly positive qPCR tests for an overall sensitivity of 86%; after exclusion of cases with only slightly positive qPCR results, sensitivity was 91%. No correlation between serum BDG levels and respiratory specimen DNA levels was found. Serologic BDG testing was negative in 25/25 controls with negative qPCR for a specificity of 100% using the predefined cutoff. In 22/25 samples (88%), no BDG was detected. Serologic BDG testing using the turbidimetric assay showed high sensitivity and specificity compared to qPCR of lower respiratory specimens for the diagnosis of PJP. Both turnover time and test performance will allow clinicians to delay or in some cases forego bronchoscopy. Copyright © 2018 American Society for Microbiology.
Rapid antigen tests for dengue virus serotypes and Zika virus in patient serum.
Bosch, Irene; de Puig, Helena; Hiley, Megan; Carré-Camps, Marc; Perdomo-Celis, Federico; Narváez, Carlos F; Salgado, Doris M; Senthoor, Dewahar; O'Grady, Madeline; Phillips, Elizabeth; Durbin, Ann; Fandos, Diana; Miyazaki, Hikaru; Yen, Chun-Wan; Gélvez-Ramírez, Margarita; Warke, Rajas V; Ribeiro, Lucas S; Teixeira, Mauro M; Almeida, Roque P; Muñóz-Medina, José E; Ludert, Juan E; Nogueira, Mauricio L; Colombo, Tatiana E; Terzian, Ana C B; Bozza, Patricia T; Calheiros, Andrea S; Vieira, Yasmine R; Barbosa-Lima, Giselle; Vizzoni, Alexandre; Cerbino-Neto, José; Bozza, Fernando A; Souza, Thiago M L; Trugilho, Monique R O; de Filippis, Ana M B; de Sequeira, Patricia C; Marques, Ernesto T A; Magalhaes, Tereza; Díaz, Francisco J; Restrepo, Berta N; Marín, Katerine; Mattar, Salim; Olson, Daniel; Asturias, Edwin J; Lucera, Mark; Singla, Mohit; Medigeshi, Guruprasad R; de Bosch, Norma; Tam, Justina; Gómez-Márquez, Jose; Clavet, Charles; Villar, Luis; Hamad-Schifferli, Kimberly; Gehrke, Lee
2017-09-27
The recent Zika virus (ZIKV) outbreak demonstrates that cost-effective clinical diagnostics are urgently needed to detect and distinguish viral infections to improve patient care. Unlike dengue virus (DENV), ZIKV infections during pregnancy correlate with severe birth defects, including microcephaly and neurological disorders. Because ZIKV and DENV are related flaviviruses, their homologous proteins and nucleic acids can cause cross-reactions and false-positive results in molecular, antigenic, and serologic diagnostics. We report the characterization of monoclonal antibody pairs that have been translated into rapid immunochromatography tests to specifically detect the viral nonstructural 1 (NS1) protein antigen and distinguish the four DENV serotypes (DENV1-4) and ZIKV without cross-reaction. To complement visual test analysis and remove user subjectivity in reading test results, we used image processing and data analysis for data capture and test result quantification. Using a 30-μl serum sample, the sensitivity and specificity values of the DENV1-4 tests and the pan-DENV test, which detects all four dengue serotypes, ranged from 0.76 to 1.00. Sensitivity/specificity for the ZIKV rapid test was 0.81/0.86, respectively, using a 150-μl serum input. Serum ZIKV NS1 protein concentrations were about 10-fold lower than corresponding DENV NS1 concentrations in infected patients; moreover, ZIKV NS1 protein was not detected in polymerase chain reaction-positive patient urine samples. Our rapid immunochromatography approach and reagents have immediate application in differential clinical diagnosis of acute ZIKV and DENV cases, and the platform can be applied toward developing rapid antigen diagnostics for emerging viruses. Copyright © 2017 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.
Comparison of wheat and rye flour solutions for skin prick testing: a multi-centre study (Stad 1).
van Kampen, V; Merget, R; Rabstein, S; Sander, I; Bruening, T; Broding, H C; Keller, C; Muesken, H; Overlack, A; Schultze-Werninghaus, G; Walusiak, J; Raulf-Heimsoth, M
2009-12-01
Skin prick testing (SPT) is the basic method for diagnosing IgE-mediated allergies. However, skin reactivity is related to the quality of allergen extracts, which are often poorly defined for occupational allergens. To compare wheat and rye flour SPT solutions from different producers. Standardized SPTs were performed in seven allergy centres with wheat and rye flour solutions from four producers in 125 symptomatic bakers. Optimal cut-off levels for weal sizes were assessed with the Youden Index. Comparisons between SPT results of different solutions were made with flour-specific IgE (sIgE) as the gold standard. Sensitivities, specificities, positive and negative predictive values, and test efficiencies were calculated and compared with McNemar and chi(2)-tests. The influence of the choice of the gold standard (sIgE or challenge) test was examined for 95 subjects. Additionally, SPT solutions were analysed for protein and antigen content. The optimal cut-off level for all SPT solutions was a weal size of >or=1.5 mm. While differences between wheat and rye flours were small, differences between producers were important. Variability of sensitivities (0.31-0.96), negative predictive values (0.42-0.91), and test efficiencies (0.54-0.90) were higher than variations of specificities (0.74-1.00) and positive predictive values (0.88-1.00). Similar results were obtained when using challenge test results as the gold standard. Variability could be explained by the different antigen contents of the SPT solutions. There is a wide variability of SPT solutions for wheat and rye flour from different producers, mainly with respect to sensitivities, negative predictive values, and test efficiencies. Improvement and standardization of SPT solutions used for the diagnosis of baker's asthma are highly recommended.
Gorday, William; Sadrzadeh, Hossein; de Koning, Lawrence; Naugler, Christopher T
2015-12-01
1.) Identify whether prostate-specific antigen velocity improves the ability to predict prostate biopsy diagnosis. 2.) Test whether there is an increase in the predictive capability of models when Gleason 7 prostate cancers are separated into a 3+4 and a 4+3 group. Calgary Laboratory Services' Clinical Laboratory Information System was searched for prostate biopsies reported between January 1, 2009 and December 31, 2013. Total prostate-specific antigen tests were recorded for each patient from January 1, 2007 to the most recent test before their recorded prostate biopsy. The data set was divided into the following three groups for comparison; benign, all prostate cancer and Gleason 7-10. The Gleason grade 7-10 group was further divided into 4+3 and 3+4 Gleason 7 prostate cancers. Prostate-specific antigen velocity was calculated using four different methods found in the literature. Receiver operator curves were used to assess operational characteristics of the tests. 4622 men between the ages of 40-89 with a prostate biopsy were included for analysis. Combining prostate-specific antigen velocity with total prostate-specific antigen (AUC=0.570-0.712) resulted in small non-statistically significant changes to the area under the curve compared to the area under the curve of total prostate-specific antigen alone (AUC=0.572-0.699). There were marked increases in the area under curves when 3+4 and 4+3 Gleason 7 cancers were separated. Prostate-specific antigen velocity does not add predictive value for prostate biopsy diagnosis. The clinical significance of the prostate specific antigen test can be improved by separating Gleason 7 prostate cancers into a 3+4 and 4+3 group. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Gillet, Philippe; Mumba Ngoyi, Dieudonné; Lukuka, Albert; Kande, Viktor; Atua, Benjamin; van Griensven, Johan; Muyembe, Jean-Jacques; Jacobs, Jan; Lejon, Veerle
2013-01-01
Background In endemic settings, diagnosis of malaria increasingly relies on the use of rapid diagnostic tests (RDTs). False positivity of such RDTs is poorly documented, although it is especially relevant in those infections that resemble malaria, such as human African trypanosomiasis (HAT). We therefore examined specificity of malaria RDT products among patients infected with Trypanosoma brucei gambiense. Methodology/Principal Findings Blood samples of 117 HAT patients and 117 matched non-HAT controls were prospectively collected in the Democratic Republic of the Congo. Reference malaria diagnosis was based on real-time PCR. Ten commonly used malaria RDT products were assessed including three two-band and seven three-band products, targeting HRP-2, Pf-pLDH and/or pan-pLDH antigens. Rheumatoid factor was determined in PCR negative subjects. Specificity of the 10 malaria RDT products varied between 79.5 and 100% in HAT-negative controls and between 11.3 and 98.8% in HAT patients. For seven RDT products, specificity was significantly lower in HAT patients compared to controls. False positive reactions in HAT were mainly observed for pan-pLDH test lines (specificities between 13.8 and 97.5%), but also occurred frequently for the HRP-2 test line (specificities between 67.9 and 98.8%). The Pf-pLDH test line was not affected by false-positive lines in HAT patients (specificities between 97.5 and 100%). False positivity was not associated to rheumatoid factor, detected in 7.6% of controls and 1.2% of HAT patients. Conclusions/Significance Specificity of some malaria RDT products in HAT was surprisingly low, and constitutes a risk for misdiagnosis of a fatal but treatable infection. Our results show the importance to assess RDT specificity in non-targeted infections when evaluating diagnostic tests. PMID:23638201
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kruger, Albert A.; Muller, I. S.; Gong, W.
2013-12-03
This report describes the results of work and testing specified by Test Specifications 24590-LAW-TSP-RT-04-004, Rev. 0, Test Plans VSL-05T5480-1, Rev. 0 and Text Exceptions 24590-LAW-TEF-RT-05-00002. The work and any associated testing followed established quality assurance requirements and was conducted as authorized. The descriptions provided in this test report are an accurate account of both the conduct of the work and the data collected. Results required by the Test Plan are reported. Also reported are any unusual or anomalous occurences that are different from the starting hypotheses. The test results and this report have been reviewed and verified.
Coccidioides complement fixation
... antibodies are detected in the blood sample. Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your health care provider about the meaning of your specific test results.
7 CFR 205.670 - Inspection and testing of agricultural product to be sold or labeled “organic.”
Code of Federal Regulations, 2010 CFR
2010-01-01
... current applicable validated methodology determining the presence of contaminants in agricultural products... an ongoing compliance investigation. (e) If test results indicate a specific agricultural product...
Cost-effectiveness of various methods of diagnosing hypersensitivity to Alternaria.
Escudero, A I; Sánchez-Guerrero, I M; Mora, A M; Soriano, V; López, J D; García, F J; Negro, J M; Hernández, J; Pagán, J A
1993-01-01
This study was undertaken for two reasons: 1) It is more difficult to diagnose hypersensitivity to molds than to other allergens, so an evaluation of diagnostic tests was needed. 2) Alternaria is the principal cause of mold sensitization in our area. Sixty-six patients (20 +/- 4 years) were selected and divided into two groups. Group A was made up of patients with rhinitis and/or asthma due to Alternaria sensitization. Group B consisted of patients sensitized to other allergens and patients with nonrespiratory allergic disorders. Skin tests (prick and intradermal), challenge tests (conjunctival, nasal, and bronchial), and specific IgE determination were performed for all patients. A biologically standardized extract of Alternaria tenuis (Alergia e Inmunología Abelló, S. A., Madrid, Spain) obtained from a single batch was used for all tests. Our diagnostic criterion was a clinical history of rhinitis or asthma that coincided with the results of nasal/bronchial challenge. The diagnostic value of the other tests was compared to this criterion. In the group of rhinitic patients, skin tests and conjunctival challenge were more sensitive than specific IgE determination. In asthmatic patients, the most sensitive techniques were nasal and conjunctival challenges, followed by prick and intradermal skin tests, and, lastly, serum specific IgE determination. When rhinitis and asthma were considered jointly, the most sensitive test was conjunctival challenge, followed by skin-prick and intradermal tests. All tests had the same specificity, regardless of disorder. Nasal challenge was positive in all patients. Skin tests are easy to perform, cheap, non-traumatic for the patient, and sufficiently specific and sensitive for the diagnosis of Alternaria hypersensitivity.(ABSTRACT TRUNCATED AT 250 WORDS)
Hermassi, Souhail; Chelly, Mohamed-Souhaiel; Wollny, Rainer; Hoffmeyer, Birgit; Fieseler, Georg; Schulze, Stephan; Irlenbusch, Lars; Delank, Karl-Stefan; Shephard, Roy J; Bartels, Thomas; Schwesig, René
2018-06-01
This study assessed the validity of the handball-specific complex test (HBCT) and two non-specific field tests in professional elite handball athletes, using the match performance score (MPS) as the gold standard of performance. Thirteen elite male handball players (age: 27.4±4.8 years; premier German league) performed the HBCT, the Yo-Yo Intermittent Recovery (YYIR) test and a repeated shuttle sprint ability (RSA) test at the beginning of pre-season training. The RSA results were evaluated in terms of best time, total time, and fatigue decrement. Heart rates (HR) were assessed at selected times throughout all tests; the recovery HR was measured immediately post-test and 10 minutes later. The match performance score was based on various handball specific parameters (e.g., field goals, assists, steals, blocks, and technical mistakes) as seen during all matches of the immediately subsequent season (2015/2016). The parameters of run 1, run 2, and HR recovery at minutes 6 and 10 of the RSA test all showed a variance of more than 10% (range: 11-15%). However, the variance of scores for the YYIR test was much smaller (range: 1-7%). The resting HR (r2=0.18), HR recovery at minute 10 (r2=0.10), lactate concentration at rest (r2=0.17), recovery of heart rate from 0 to 10 minutes (r2=0.15), and velocity of second throw at first trial (r2=0.37) were the most valid HBCT parameters. Much effort is necessary to assess MPS and to develop valid tests. Speed and the rate of functional recovery seem the best predictors of competitive performance for elite handball players.
Iwelunmor, Juliet; Blackstone, Sarah; Jennings, Larissa; Converse, Donaldson; Ehiri, John; Curley, Jami
2018-04-09
Purpose Many adolescent girls in Nigeria do not test for HIV despite being at high risk. While the influence of psychosocial factors on HIV testing has been examined, there is less evidence regarding the impact of assets and control of assets on HIV testing. This study investigated the protective effects of specific adolescent girls' assets on decision-making regarding HIV testing. Methods Cross-sectional data from the 2013 Nigeria Demographic and Health Survey was analyzed. The main outcome variables were self-reports of having been tested for HIV and knowledge of a place that offers HIV testing. Binary logistic regression was used with employment, education, wealth index, home ownership, land ownership and decision making as potential predictors. Demographic characteristics were controlled in the analysis. Results Age [odds ratio (OR = 1.49)], employment (OR = 3.38), education (OR = 3.16), wealth index (OR = 1.33) and decision making (OR = 3.16) were positively associated with HIV testing. Age (OR = 1.20), employment (OR = 1.33), education (OR = 1.38), wealth (OR = 1.64), land ownership (OR = 1.42), and decision making (OR = 1.26) were positively associated with knowledge of an HIV testing location. Conclusion Our findings suggest that assets play an important role with HIV testing decisions for adolescent girls. Further research to elucidate the specific asset-based needs of adolescent girls will be needed to enhance decisions surrounding uptake of HIV testing and receipt of test results in Nigeria.
Fast specific field detection of RHDVb.
Dalton, K P; Nicieza, I; Podadera, A; de Llano, D; Martin Alonso, J M; de Los Toyos, J R; García Ocaña, M; Vázquez-Villa, F; Velasco, B; Landeta, O; Parra, F
2018-02-01
This work describes a simple and rapid test for field detection of the emerging rabbit pathogen RHDVb. The assay is specific for RHDVb, showing no cross-reactivity with other RHDV types giving a specific result in under 10 min using rabbit liquid exudates or liver homogenate samples taken at necropsy. © 2017 Blackwell Verlag GmbH.
Frequency optimization in the eddy current test for high purity niobium
NASA Astrophysics Data System (ADS)
Joung, Mijoung; Jung, Yoochul; Kim, Hyungjin
2017-01-01
The eddy current test (ECT) is frequently used as a non-destructive method to check for the defects of high purity niobium (RRR300, Residual Resistivity Ratio) in a superconducting radio frequency (SRF) cavity. Determining an optimal frequency corresponding to specific material properties and probe specification is a very important step. The ECT experiments for high purity Nb were performed to determine the optimal frequency using the standard sample of high purity Nb having artificial defects. The target depth was considered with the treatment step that the niobium receives as the SRF cavity material. The results were analysed via the selectivity that led to a specific result, depending on the size of the defects. According to the results, the optimal frequency was determined to be 200 kHz, and a few features of the ECT for the high purity Nb were observed.
Effects of a Carbohydrate-Electrolyte Drink on Specific Soccer Tests and Performance
Ostojic, Sergej M.; Mazic, Sanja
2002-01-01
The aim of this study was to examine the effects of a carbohydrate-electrolyte drink on specific soccer tests and performance. Twenty-two professional male soccer players volunteered to participate in the study. The players were allocated to two assigned trials ingesting carbohydrate-electrolyte drink (7% carbohydrates, sodium 24 mmol.l-1, chloride 12 mmol.l-1, potassium 3 mmol.l-1) or placebo during a 90 min on-field soccer match. The trials were matched for subjects’ age, weight, height and maximal oxygen uptake. Immediately after the match, players completed four soccer-specific skill tests. Blood glucose concentration [mean (SD)] was higher at the end of the match-play in the carbohydrate-electrolyte trial than in the placebo trial (4.4 (0.3) vs. 4.0 (0.3) mmol.l-1, P < 0.05). Subjects in the carbohydrate-electrolyte trial finished the specific dribble test faster in comparison with subjects in the placebo trial (12.9 (0.4) vs. 13.6 (0.5) s, P < 0.05). Ratings of the precision test were higher in the carbohydrate-electrolyte trial as compared to the placebo trial (17.2 (4.8) vs. 15.1 (5.2), P < 0.05) but there were no differences in coordination test and power test results between trials. The main finding of the present study indicates that supplementation with carbohydrate-electrolyte solution improved soccer-specific skill performance and recovery after an on-field soccer match compared with ingestion of placebo. This suggests that soccer players should consume carbohydrate-electrolyte fluid throughout a game to help prevent deterioration in specific skill performance. PMID:24688270
Iwata, Eiichiro; Shigematsu, Hideki; Inoue, Kazuya; Egawa, Takuya; Sakamoto, Yoshihiro; Tanaka, Yasuhito
2017-01-01
Rotator cuff tears and cervical spondylotic amyotrophy (CSA) are often confused as the main symptom in those with difficulty in shoulder elevation. Empty and full can tests are frequently used for the clinical diagnosis of rotator cuff tears. The aim of the present study was to investigate whether the empty and full can test results can help differentiate rotator cuff tears from CSA. Twenty-seven consecutive patients with rotator cuff tears and 25 with CSA were enrolled. We prospectively performed empty and full can tests in patients with rotator cuff tears and CSA. The following signs were considered positive: (a) muscle weakness during the empty can test, (b) muscle weakness during the full can test, (c) pain provocation during the empty can test, and (d) pain provocation during the full can test. We calculated the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of rotator cuff tears for each positive finding. The sensitivity and specificity of each index were as follows (sensitivity, specificity, PPV, NPV): (a) 77.8%, 0%, 45.7%, 0%; (b) 66.7%, 4.0%, 42.9%, 10.0%; (c) 88.9%, 96.0%, 96.0%, 88.9%; and (d) 74.1%, 96.0%, 95.2%, 77.4%. There were significant differences for each index. Muscle weakness during the empty and full can tests was not useful in differentiating rotator cuff tears from CSA because of low specificity and PPV. However, pain provocation was useful in differentiating these two conditions because of high specificity and PPV.
Caetano, Ana C; Santa-Cruz, André; Rolanda, Carla
2016-01-01
Background . Rome III criteria add physiological criteria to symptom-based criteria of chronic constipation (CC) for the diagnosis of defecatory disorders (DD). However, a gold-standard test is still lacking and physiological examination is expensive and time-consuming. Aim . Evaluate the usefulness of two low-cost tests-digital rectal examination (DRE) and balloon expulsion test (BET)-as screening or excluding tests of DD. Methods . We performed a systematic search in PUBMED and MEDLINE. We selected studies where constipated patients were evaluated by DRE or BET. Heterogeneity was assessed and random effect models were used to calculate the sensitivity, specificity, and negative predictive value (NPV) of the DRE and the BET. Results . Thirteen studies evaluating BET and four studies evaluating DRE (2329 patients) were selected. High heterogeneity ( I 2 > 80%) among studies was demonstrated. The studies evaluating the BET showed a sensitivity and specificity of 67% and 80%, respectively. Regarding the DRE, a sensitivity of 80% and specificity of 84% were calculated. NPV of 72% for the BET and NPV of 64% for the DRE were estimated. The sensitivity and specificity were similar when we restrict the analysis to studies using Rome criteria to define CC. The BET seems to perform better when a cut-off time of 2 minutes is used and when it is compared with a combination of physiological tests. Considering the DRE, strict criteria seem to improve the sensitivity but not the specificity of the test. Conclusion . Neither of the low-cost tests seems suitable for screening or excluding DD.
Fernández, J; Torres, M J; Campos, J; Arribas-Poves, F; Blanca, M
2013-01-01
Allergy to penicillin is the most commonly reported type of drug hypersensitivity. Diagnosis is currently confirmed using skin tests with benzylpenicillin reagents, ie, penicilloyl-polylysine (PPL) as the major determinant of benzylpenicillin and benzylpenicillin, benzylpenicilloate and benzylpenilloate as a minor determinant mixture (MDM). To synthesize and assess the diagnostic capacity of 2 new benzylpenicillin reagents in patients with immediate hypersensitivity reactions to B-lactams: benzylpenicilloyl octa-L-lysine (BP-OL) as the major determinant and benzylpenilloate (penilloate) as the minor determinant. Prospective multicenter clinical trial performed in 18 Spanish centers. Efficacy was assessed by detection of positive skin test results in an allergic population and negative skin test results in a nonallergic, drug-exposed population. Sensitivity, specificity, and negative and positive predictive values were determined. The study sample comprised 94 allergic patients: 31 (35.23%) presented anaphylaxis, 4 (4.55%) anaphylactic shock, 51 (58.04%) urticaria, and 2 (2.27%) no specific condition. The culprit 8-lactams were amoxicillin in 63 cases (71.60%), benzypencillin in 14 cases (15.89%), cephalosporins in 2 cases (2.27%), other drugs in 3 cases (3.42%), and unidentified agents in 6 cases (6.82%). The results of testing with BP-OL were positive in 46 cases (52.3%); the results of testing with penilloate were positive in 33 cases (37.5%). When both reagents were taken into consideration, sensitivity reached 61.36% and specificity 100%. Skin testing with penilloate was significantly more often negative when the interval between the reaction and the study was longer. The sensitivity of BP-OL and penilloate was 61%. Considering that amoxicillin was the culprit drug in 71% of reactions, these results indicate that most patients were allergic to the whole group of penicillins. These data support the use of benzylpenicillin determinants in the diagnosis of allergy to beta-lactams, even in predominantly amoxicillin-allergic populations.
Olivry, Thierry; Saridomichelakis, Manolis
2013-04-01
Anti-allergic drugs (e.g. antihistamines, glucocorticoids and ciclosporin) are often administered to dogs with atopic dermatitis to relieve pruritus and skin lesions. Allergen-specific intradermal tests (IDT) and allergen-specific IgE serological (ASIS) tests are used to characterize the allergens to which dogs are hypersensitive. Anti-allergic drugs have the potential to influence the results or interpretation of these tests. To provide evidence-based recommendations for anti-allergic drug withdrawal times before IDT and ASIS tests. Three citation databases and abstracts from international meetings were searched for relevant studies. Studies were grouped based on similar interventions and types of tests. Withdrawal times for each type of drug and test were then extrapolated from the study results. Before the assessment of immediate reactions to IDT, proposed optimal withdrawal times for antihistamines, oral glucocorticoids, topical/otic glucocorticoids and ciclosporin are 7, 14, 14 and 0 days, respectively. Studies have provided no evidence for drug withdrawal prior to ASIS tests for oral ciclosporin or prednisone/prednisolone. Owing to a lack of studies, recommendations for withdrawal times before ASIS tests cannot be made for topical glucocorticoids and antihistamines. These proposed withdrawal times are based on the existing evidence at the end of 2011. Care must be taken before extrapolating the suggested withdrawal times to other species, higher dosages, different formulations and/or durations of administration of tested drugs, as well as to other medications from the same category. © 2013 The Authors. Veterinary Dermatology © 2013 ESVD and ACVD.
Attitudes towards cannabis use and genetic testing for schizophrenia
Schiffman, Jason; Lawrence, Ryan E.; Demro, Caroline; Appelbaum, Paul S.; Dixon, Lisa
2014-01-01
Aim Within schizophrenia, genetic factors contribute greatly to risk, yet genetic testing for the disorder is not available. For some individuals with specific genotypes, cannabis use may increase risk of schizophrenia. It is possible that genetic tests could be offered in the future to inform individuals of the risk of schizophrenia if they use cannabis. Previous research, however, provides little guidance on how young adults might respond to such tests. Methods We assessed a group of young adults (n = 83) to determine how the perceived magnitude of increased risk for schizophrenia in the presence of cannabis use influences decisions to undergo genetic testing, as well as subsequent attitudes and intentions towards cannabis use. Results Participants were significantly more likely to indicate willingness to get tested if the results identified a 10% risk versus a 2% risk of schizophrenia. Participants also indicated that if the results of their test reflected increased risk due to cannabis use, it would be more important to avoid cannabis in the 10% risk scenario as compared to the 2% risk scenario. These findings remained consistent among a subset of participants who indicated cannabis use. Conclusions Results suggest that cannabis users and non-users were positively influenced in terms of intentions to change behavior based on the magnitude of risk conveyed by genetic testing. These findings provide an initial step towards understanding young people’s attitudes towards genetic testing and may help prepare interventions specifically tailored around cannabis use reduction for people at risk for schizophrenia. PMID:24957110
Köksal, Ozlem; Ozdemir, Fatma; Armağan, Erol; Oner, Nuran; Sert, Pınar Çinar; Sigirli, Deniz
2013-01-01
This study aimed to determine the necessity of pregnancy test in women of reproductive age admitted to emergency department (ED) in routine practice. We retrospectively reviewed the records of patients who presented to the ED between January 1, 2006 and December 31, 2010 and received a pregnancy test. The median age of 1 586 patients enrolled into the study was 27 years. Of these patients, 19.55% had a positive result of pregnancy test. The most common complaint at admission was abdominal pain in 60.15% of the patients, and pregnancy test was prescribed. 15.83% of the patients with abdominal pain had a positive result of pregnancy test. Of the patients, 30.64% had nausea-vomiting at admission, and 11.52% had a positive result of pregnancy test. When other complaints were considered, the most commonly observed complaints were non-specific symptoms such as dizziness, malaise and respiratory problems. Of the patients, 70.93% were not remembering the date of last menstruation, and 9.51% showed a positive result of pregnancy test. Urinary tract infection (UTI) was commonly diagnosed with an incidence of 17.65%, which was followed by non-specific abdominal pain (NSAP) (16.77%) and gastrointestinal disorders such as gastritis and peptic ulcer (6.87%). Of the patients, 88.40% were discharged from ED, and 11.60% were hospitalized. Pregnancy test should be given to women of reproductive age as a routine practice in ED in developing countries like Turkey.
NASA Astrophysics Data System (ADS)
Wang, Jing; Feng, Shangyuan; Lin, Juqiang; Zeng, Yongyi; Li, Ling; Huang, Zufang; Li, Buhong; Zeng, Haishan; Chen, Rong
2013-11-01
Surface-enhanced Raman spectroscopy (SERS) of serum albumin and globulin were employed to detect hepatocellular carcinoma (HCC). Tentative assignments of SERS bands show specific biomolecular changes associated with cancer development. These changes include a decrease in relative amounts of tryptophan, glutamine, glycine, and serine, indicating excessive consumption of amino acids for protein duplication. Principal component analysis was also introduced to analyze the obtained spectra, resulting in both diagnostic sensitivity and specificity of 100%. More importantly, it reveals that this method can detect HCC patients with alpha-fetoprotein negative test results, suggesting its great potential as a new alternative to detect HCC.
2008-06-06
Human brucellosis, a nationally notifiable disease, is uncommon in the United States. Most human cases have occurred in returned travelers or immigrants from regions where brucellosis is endemic, or were acquired domestically from eating illegally imported, unpasteurized fresh cheeses. In January 2005, a woman aged 35 years who lived in Nassau County, Florida, received a diagnosis of brucellosis, based on results of a Brucella immunoglobulin M (IgM) enzyme immunoassay (EIA) performed in a commercial laboratory using analyte specific reagents (ASRs); this diagnosis prompted an investigation of dairy products in two other states. Subsequent confirmatory antibody testing by Brucella microagglutination test (BMAT) performed at CDC on the patient's serum was negative. The case did not meet the CDC/Council of State and Territorial Epidemiologists' (CSTE) definition for a probable or confirmed brucellosis case, and the initial EIA result was determined to be a false positive. This report summarizes the case history, laboratory findings, and public health investigations. CDC recommends that Brucella serology testing only be performed using tests cleared or approved by the Food and Drug Administration (FDA) or validated under the Clinical Laboratory Improvement Amendments (CLIA) and shown to reliably detect the presence of Brucella infection. Results from these tests should be considered supportive evidence for recent infection only and interpreted in the context of a clinically compatible illness and exposure history. EIA is not considered a confirmatory Brucella antibody test; positive screening test results should be confirmed by Brucella-specific agglutination (i.e., BMAT or standard tube agglutination test) methods.
Specificity of a whole blood IGRA in German nursing students
2011-01-01
Background Interferon-gamma release assays (IGRA) are used for tuberculosis (TB) screening in healthcare workers (HCWs). However, data on specificity of IGRA in serial testing of HCWs is sparse. Therefore the specificity and the negative predictive value of the IGRA - QuantiFERON-TB Gold In-Tube (QFT) - in German nursing students was investigated. Methods 194 nursing students at the start of their professional career were tested with the QFT. 14 nursing students were excluded from the specificity analysis, due to exposure to mycobacterium tuberculosis. Two of these subjects were QFT- positive. None of them developed disease during the year of follow-up. A study group of 180 students, all with very low risk of prior TB infection, remained in the specificity analysis. Subjects were monitored for at least two years with respect to the development of active TB disease. IGRA was performed at the start of the training and after one year. Results The mean age of the study group (n = 180) was 23 years (range 18-53) with 70.9% female and 99.4% German born. The specificity of QFT was 98.9% (178/180; 95% CI 0.96-0.99); lowering the cut-off from 0.35 IU/ml to 0.1 IU/ml would have decreased specificity only slightly to 97.8% (176/180; 95% CI 0.94-0.99). Of the 154 nursing students available for re-testing, one student who initially scored positive reverted to negative, and one student initially negative converted to positive. None of the monitored group with initially negative QFT results developed TB disease, indicating a high negative predictive value of the IGRA in this population. Conclusions Following our data, QFT can serve as an effective tool in pre-employment TB screenings for HCWs. As its negative results were stable over time, specificity of the QFT in serial testing of HCWs is high. As the risk of acquiring TB infection in the German healthcare system appears to be low, our data supports the recommendation of performing TB screening only in those HCWs with known contact to TB patients or infectious materials. PMID:21929799
Cox, Linda; Williams, Brock; Sicherer, Scott; Oppenheimer, John; Sher, Larry; Hamilton, Robert; Golden, David
2008-12-01
The intended purpose of this monograph is to provide a general overview of allergy diagnostics for health care professionals who care for patients with allergic disease. For a more comprehensive review of allergy diagnostic testing, readers can refer to the Allergy Diagnostic Practice Parameters. A key message is that a positive allergy test result (skin or blood) indicates only the presence of allergen specific IgE (called sensitization). It does not necessarily mean clinical allergy (ie, allergic symptoms with exposure). It is important for this reason that the allergy evaluation be based on the patient's history and directed by a health care professional with sufficient understanding of allergy diagnostic testing to use the information obtained from his/her evaluation of the patient to determine (1) what allergy diagnostic tests to order, (2) how to interpret the allergy diagnostic test results, and (3) how to use the information obtained from the allergy evaluation to develop an appropriate therapeutic treatment plan.
Prospective Study of Serologic Tests for Lyme Disease
Steere, Allen C.; McHugh, Gail; Damle, Nitin; Sikand, Vijay K.
2017-01-01
Background Tests to determine serum antibody levels—the 2-tier sonicate immunoglobulin M (IgM) and immunoglobulin G (IgG) enzyme-linked immunosorbent assay (ELISA) and Western blot method or the IgG of the variable major protein-like sequence-expressed (VlsE) sixth invariant region (C6) peptide ELISA method—are the major tests available for support of the diagnosis of Lyme disease. However, these tests have not been assessed prospectively. Methods We used these tests prospectively to determine serologic responses in 134 patients with various manifestations of Lyme disease, 89 patients with other illnesses (with or without a history of Lyme disease), and 136 healthy subjects from areas of endemicity and areas in which the infection was not endemic. Results With 2-tier tests and the C6 peptide ELISA, only approximately one-third of 76 patients with erythema migrans had results that were positive for IgM or IgG seroreactivity with Borrelia burgdorferi in acute-phase samples. During convalescence, 3–4 weeks later, almost two-thirds of patients had seroreactivity with the spirochete B. burgdorferi. The frequencies of seroreactivity were significantly greater among patients with spirochetal dissemination than they were among those who lacked evidence of disseminated disease. Of the 44 patients with Lyme disease who had neurologic, heart, or joint involvement, all had positive C6 peptide ELISA results, 42 had IgG responses with 2-tier tests, and 2 patients with facial palsy had only IgM responses. However, among the control groups, the IgG Western blot was slightly more specific than the C6 peptide ELISA. The differences between the 2 test systems (2-tier testing and C6 peptide ELISA) with respect to sensitivity and specificity were not statistically significant. Conclusions Except in patients with erythema migrans, both test systems were sensitive for support of the diagnosis of Lyme disease. However, with current methods, 2-tier testing was associated with slightly better specificity. PMID:18532885
Savasoglu, Kaan; Payzin, Kadriye Bahriye; Ozdemirkiran, Fusun; Berber, Belgin
2015-08-01
To determine the use of the Quantitative Real Time PCR (RQ-PCR) assay follow-up with Chronic Myeloid Leukemia (CML) patients. Cross-sectional observational. Izmir Ataturk Education and Research Hospital, Izmir, Turkey, from 2009 to 2013. Cytogenetic, FISH, RQ-PCR test results from 177 CMLpatients' materials selected between 2009 - 2013 years was set up for comparison analysis. Statistical analysis was performed to compare between FISH, karyotype and RQ-PCR results of the patients. Karyotyping and FISH specificity and sensitivity rates determined by ROC analysis compared with RQ-PCR results. Chi-square test was used to compare test failure rates. Sensitivity and specificity values were determined for karyotyping 17.6 - 98% (p=0.118, p > 0.05) and for FISH 22.5 - 96% (p=0.064, p > 0.05) respectively. FISH sensitivity was slightly higher than karyotyping but there was calculated a strong correlation between them (p < 0.001). RQ-PCR test failure rate did not correlate with other two tests (p > 0.05); however, karyotyping and FISH test failure rate was statistically significant (p < 0.001). Besides, the situation needed for karyotype analysis, RQ-PCR assay can be used alone in the follow-up of CMLdisease.
NASA Technical Reports Server (NTRS)
Putkovich, K.
1981-01-01
Initial test results indicated that the Global Positioning System/Time Transfer Unit (GPS/TTU) performed well within the + or - 100 nanosecond range required by the original system specification. Subsequent testing involved the verification of GPS time at the master control site via portable clocks and the acquisition and tracking of as many passes of the space vehicles currently in operation as possible. A description and discussion of the testing, system modifications, test results obtained, and an evaluation of both GPS and the GPS/TTU are presented.
A three-dimensional printed patient-specific scaphoid replacement: a cadaveric study.
Honigmann, Philipp; Schumacher, Ralf; Marek, Romy; Büttner, Franz; Thieringer, Florian; Haefeli, Mathias
2018-05-01
We present our first cadaveric test results of a three-dimensional printed patient-specific scaphoid replacement with tendon suspension, which showed normal motion behaviour and preservation of a stable scapholunate interval during physiological range of motion.
GERM-LINE SPECIFIC FACTORS IN CHEMICAL MUTAGENESIS
Chemical mutagenesis test results ave not revealed evidence of germ-line specific mutagens. owever, conventional assays have indicated that there are male-female differences in mutagenic response, as well as quantitative/qualitative differences in induced mutations which depend u...
Illustrative case studies in the return of exome and genome sequencing results
Amendola, Laura M; Lautenbach, Denise; Scollon, Sarah; Bernhardt, Barbara; Biswas, Sawona; East, Kelly; Everett, Jessica; Gilmore, Marian J; Himes, Patricia; Raymond, Victoria M; Wynn, Julia; Hart, Ragan; Jarvik, Gail P
2015-01-01
Whole genome and exome sequencing tests are increasingly being ordered in clinical practice, creating a need for research exploring the return of results from these tests. A goal of the Clinical Sequencing and Exploratory Research (CSER) consortium is to gain experience with this process to develop best practice recommendations for offering exome and genome testing and returning results. Genetic counselors in the CSER consortium have an integral role in the return of results from these genomic sequencing tests and have gained valuable insight. We present seven emerging themes related to return of exome and genome sequencing results accompanied by case descriptions illustrating important lessons learned, counseling challenges specific to these tests and considerations for future research and practice. PMID:26478737
Galileo battery testing and the impact of test automation
NASA Technical Reports Server (NTRS)
Pertuch, W. T.; Dils, C. T.
1985-01-01
Test complexity, changes of test specifications, and the demand for tight control of tests led to the development of automated testing used for Galileo and other projects. The use of standardized interfacing, i.e., IEEE-488, with desktop computers and test instruments, resulted in greater reliability, repeatability, and accuracy of both control and data reporting. Increased flexibility of test programming has reduced costs by permitting a wide spectrum of test requirements at one station rather than many stations.
Corstjens, Paul L A M; Hoekstra, Pytsje T; de Dood, Claudia J; van Dam, Govert J
2017-11-01
Methodological applications of the high sensitivity genus-specific Schistosoma CAA strip test, allowing detection of single worm active infections (ultimate sensitivity), are discussed for efficient utilization in sample pooling strategies. Besides relevant cost reduction, pooling of samples rather than individual testing can provide valuable data for large scale mapping, surveillance, and monitoring. The laboratory-based CAA strip test utilizes luminescent quantitative up-converting phosphor (UCP) reporter particles and a rapid user-friendly lateral flow (LF) assay format. The test includes a sample preparation step that permits virtually unlimited sample concentration with urine, reaching ultimate sensitivity (single worm detection) at 100% specificity. This facilitates testing large urine pools from many individuals with minimal loss of sensitivity and specificity. The test determines the average CAA level of the individuals in the pool thus indicating overall worm burden and prevalence. When requiring test results at the individual level, smaller pools need to be analysed with the pool-size based on expected prevalence or when unknown, on the average CAA level of a larger group; CAA negative pools do not require individual test results and thus reduce the number of tests. Straightforward pooling strategies indicate that at sub-population level the CAA strip test is an efficient assay for general mapping, identification of hotspots, determination of stratified infection levels, and accurate monitoring of mass drug administrations (MDA). At the individual level, the number of tests can be reduced i.e. in low endemic settings as the pool size can be increased as opposed to prevalence decrease. At the sub-population level, average CAA concentrations determined in urine pools can be an appropriate measure indicating worm burden. Pooling strategies allowing this type of large scale testing are feasible with the various CAA strip test formats and do not affect sensitivity and specificity. It allows cost efficient stratified testing and monitoring of worm burden at the sub-population level, ideally for large-scale surveillance generating hard data for performance of MDA programs and strategic planning when moving towards transmission-stop and elimination.
Tsai, J J; Kao, M H; Wu, C H
1998-11-01
This study was performed to test the hypersensitivity of asthmatics to American and German cockroaches, which are both common in Taiwan. A total of 236 asthmatic patients received skin prick test using allergen extracts from both American and German cockroaches, and 596 sera from asthmatic patients were analyzed for their specific IgE against German cockroach extract. The results of skin test showed that 39.4 and 36.4% asthmatic patients were hypersensitive to American and German cockroaches. Fifteen among 236 patients were only allergic to American cockroaches and 8 were only allergic to German cockroaches. Using the Pharmacia CAP system, 36% of the sera were found to contain the specific IgE to German cockroach extract. Eighty-nine sera positive for German cockroach extract were then tested for their reactivity to American cockroach extract using the fluoroallergosorbent test (FAST). Sixty among 89 (68%) of their sera contained American cockroach-specific IgE. The correlation coefficient between both parameters was r = 0.45. Immunoblot and immunoblot inhibition studies were performed to analyze the IgE-binding components and the cross-reactivity between American and German cockroaches. The results showed that there are different IgE-binding components between American and German cockroaches. Sera containing specific IgE to both species of cockroach were absorbed with both species of cockroach extracts. The specific IgE to German cockroaches can be absorbed by American cockroach extract in all selected sera and the specific IgE to American cockroaches can only partially be absorbed by German cockroaches. The nonabsorbed allergens in American cockroaches had molecular weights of 33 and 50 kD. In conclusion, one-third of the asthmatic population tested was allergic to cockroaches. Although most cockroach-hypersensitive patients were allergic to both American and German cockroaches, more asthmatic patients were allergic to American cockroaches in Taiwan. The use of non-crossreacting allergen in detecting American cockroach-specific IgE might be important not only for the diagnosis and treatment of cockroach hypersensitivity in asthmatics but also for the differentiation between German and American cockroach hypersensitivity.
Weissberger, Gali H.; Strong, Jessica V.; Stefanidis, Kayla B.; Summers, Mathew J.; Bondi, Mark W.; Stricker, Nikki H.
2018-01-01
With an increasing focus on biomarkers in dementia research, illustrating the role of neuropsychological assessment in detecting mild cognitive impairment (MCI) and Alzheimer’s dementia (AD) is important. This systematic review and meta-analysis, conducted in accordance with PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) standards, summarizes the sensitivity and specificity of memory measures in individuals with MCI and AD. Both meta-analytic and qualitative examination of AD versus healthy control (HC) studies (n = 47) revealed generally high sensitivity and specificity (≥ 80% for AD comparisons) for measures of immediate (sensitivity = 87%, specificity = 88%) and delayed memory (sensitivity = 89%, specificity = 89%), especially those involving word-list recall. Examination of MCI versus HC studies (n = 38) revealed generally lower diagnostic accuracy for both immediate (sensitivity = 72%, specificity = 81%) and delayed memory (sensitivity = 75%, specificity = 81%). Measures that differentiated AD from other conditions (n = 10 studies) yielded mixed results, with generally high sensitivity in the context of low or variable specificity. Results confirm that memory measures have high diagnostic accuracy for identification of AD, are promising but require further refinement for identification of MCI, and provide support for ongoing investigation of neuropsychological assessment as a cognitive biomarker of preclinical AD. Emphasizing diagnostic test accuracy statistics over null hypothesis testing in future studies will promote the ongoing use of neuropsychological tests as Alzheimer’s disease research and clinical criteria increasingly rely upon cerebrospinal fluid (CSF) and neuroimaging biomarkers. PMID:28940127
Ariza, A; Barrionuevo, E; Mayorga, C; Montañez, M I; Perez-Inestrosa, E; Ruiz-Sánchez, A; Rodríguez-Guéant, R M; Fernández, T D; Guéant, J L; Torres, M J; Blanca, M
2014-04-01
Quantitation of specific IgE by immunoassay is a recommended in vitro test for the diagnosis of immediate hypersensitivity reactions to betalactams (BLs), particularly when skin test results are negative. IgE antibodies that recognize the common nuclear structure of all BLs or the specific side chain structure can be mainly distinguished by immunoassays. The aim of this study was to develop an immunoassay system to detect IgE antibodies with different specificities. Cellulose discs conjugated with benzylpenicillin (BP), amoxicillin (AX) or both drugs, with poly-l-lysine (PLL) as carrier molecule, were used as solid phases in the radioallergosorbent test (RAST). Direct and inhibition radioimmunoassay studies were made to verify the structures recognized by serum IgE antibodies from penicillin-allergic patients. Our results indicated that the addition of both haptens did not decrease the capacity to capture IgE when serum specific to either BP or AX was used, at least in terms of sensitivity. In addition, the inclusion of two haptens improved significantly the levels of IgE detection in patients who recognized both BP and AX. Therefore, the use of a solid phase with a carrier molecule conjugated with two determinants (AX and BP) is helpful to recognize IgE antibodies against either of these determinants and is useful for screening sera with different specificities. Copyright © 2014 Elsevier B.V. All rights reserved.
Sarink, M J; Koelewijn, R; Slingerland, B C G C; Tielens, A G M; van Genderen, P J J; van Hellemond, J J
2018-06-28
Diagnosis of cystic echinococcosis (CE) is at present mainly based on imaging techniques. Serology has a complementary role, partly due to the small number of standardized and commercially available assays. Therefore we examined the clinical performance of the SERION ELISA classic Echinococcus IgG test. Using 10 U/ml as a cut-off point, and serum samples from 50 CE patients and 105 healthy controls, the sensitivity and specificity were 98.0% and 96.2%, respectively. If patients with other infectious diseases were used as negative controls, the specificity decreased to 76.9%, which causes poor positive predictive values. However, if results between 10 and 15 U/ml are classified as indecisive, the specificity of positive results (≥15 U/ml) increased to 92.5% without greatly affecting the sensitivity (92.0%). Using this approach in combination with imaging studies, the SERION ELISA classic Echinococcosis IgG test can be a useful aid in the diagnosis of CE.
Ariza, Mar; Pueyo, Roser; Junqué, Carme; Mataró, María; Poca, María Antonia; Mena, Maria Pau; Sahuquillo, Juan
2006-09-01
The aim of the present study was to determine whether the type of lesion in a sample of moderate and severe traumatic brain injury (TBI) was related to material-specific memory impairment. Fifty-nine patients with TBI were classified into three groups according to whether the site of the lesion was right temporal, left temporal or diffuse. Six-months post-injury, visual (Warrington's Facial Recognition Memory Test and Rey's Complex Figure Test) and verbal (Rey's Auditory Verbal Learning Test) memories were assessed. Visual memory deficits assessed by facial memory were associated with right temporal lobe lesion, whereas verbal memory performance assessed with a list of words was related to left temporal lobe lesion. The group with diffuse injury showed both verbal and visual memory impairment. These results suggest a material-specific memory impairment in moderate and severe TBI after focal temporal lesions and a non-specific memory impairment after diffuse damage.
Computer-aided detection in musculoskeletal projection radiography: A systematic review.
Gundry, M; Knapp, K; Meertens, R; Meakin, J R
2018-05-01
To investigated the accuracy of computer-aided detection (CAD) software in musculoskeletal projection radiography via a systematic review. Following selection screening, eligible studies were assessed for bias, and had their study characteristics extracted resulting in 22 studies being included. Of these 22 three studies had tested their CAD software in a clinical setting; the first study investigated vertebral fractures, reporting a sensitivity score of 69.3% with CAD, compared to 59.8% sensitivity without CAD. The second study tested dental caries diagnosis producing a sensitivity score of 68.8% and specificity of 94.1% with CAD, compared to sensitivity of 39.3% and specificity of 96.7% without CAD. The third indicated osteoporotic cases based on CAD, resulting in 100% sensitivity and 81.3% specificity. The current evidence reported shows a lack of development into the clinical testing phase; however the research does show future promise in the variation of different CAD systems. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
DOT National Transportation Integrated Search
2008-04-25
This report presents the results of the ITS Standards Testing Program for the field testing, assessment, and evaluation of the NTCIP standards that apply in the domain of Dynamic Message Signs (DMS). Specifically, the National Transportation Communic...
Custodio, Nilton; Lira, David; Herrera-Perez, Eder; Montesinos, Rosa; Castro-Suarez, Sheila; Cuenca-Alfaro, José; Valeriano-Lorenzo, Lucía
2017-01-01
Background/Aims : Short tests to early detection of the cognitive impairment are necessary in primary care setting, particularly in populations with low educational level. The aim of this study was to assess the performance of Memory Alteration Test (M@T) to discriminate controls, patients with amnestic Mild Cognitive Impairment (aMCI) and patients with early Alzheimer's Dementia (AD) in a sample of individuals with low level of education. Methods : Cross-sectional study to assess the performance of the M@T (study test), compared to the neuropsychological evaluation (gold standard test) scores in 247 elderly subjects with low education level from Lima-Peru. The cognitive evaluation included three sequential stages: (1) screening (to detect cases with cognitive impairment); (2) nosological diagnosis (to determinate specific disease); and (3) classification (to differentiate disease subtypes). The subjects with negative results for all stages were considered as cognitively normal (controls). The test performance was assessed by means of area under the receiver operating characteristic (ROC) curve. We calculated validity measures (sensitivity, specificity and correctly classified percentage), the internal consistency (Cronbach's alpha coefficient), and concurrent validity (Pearson's ratio coefficient between the M@T and Clinical Dementia Rating (CDR) scores). Results : The Cronbach's alpha coefficient was 0.79 and Pearson's ratio coefficient was 0.79 ( p < 0.01). The AUC of M@T to discriminate between early AD and aMCI was 99.60% (sensitivity = 100.00%, specificity = 97.53% and correctly classified = 98.41%) and to discriminate between aMCI and controls was 99.56% (sensitivity = 99.17%, specificity = 91.11%, and correctly classified = 96.99%). Conclusions : The M@T is a short test with a good performance to discriminate controls, aMCI and early AD in individuals with low level of education from urban settings.
Larenas-Linnemann, Désirée; Luna-Pech, Jorge A; Mösges, Ralph
2017-01-01
Percutaneous skin prick tests (SPT) have been considered the preferred method for confirming IgE-mediated sensitization. This reliable and minimally invasive technique correlates with in vivo challenges, has good reproducibility, is easily quantified, and allows analyzing multiple allergens simultaneously. Potent extracts and a proficient tester improve its accuracy. Molecular-based allergy diagnostics (MA-Dx) quantifies allergenic components obtained either from purification of natural sources or recombinant technology to identify the patient's reactivity to those specific allergenic protein components. For a correct allergy diagnosis, the patient selection is crucial. MA-Dx has been shown to have a high specificity, however, as MA-Dx testing can be ordered by any physician, the pre-selection of patients might not always be optimal, reducing test specificity. Also, MA-Dx is less sensitive than in vitro testing with the whole allergen or SPT. Secondly, no allergen-specific immunotherapy (AIT) trial has yet shown efficacy with patients selected on the basis of their MA-Dx results. Thirdly, why would we need molecular diagnosis, as no molecular treatment can yet be offered? Then there are the practical arguments of costs (SPT highly cost-efficient), test availability for MA-Dx still lacking in wide areas of the world and scarce in others. As such, it is hard physicians can build confidence in the test and their interpretation of the MA-Dx results. as of now these techniques should be reserved for situations of complex allergies and polysensitization; in the future MA-Dx might help to reduce the number of allergens for AIT, but trials are needed to prove this concept.
Temstet, A; Roux, P; Poirot, J L; Ronin, O; Dromer, F
1992-01-01
Cryptococcal antigen detection has become a routine biological test performed for patients with AIDS. The poor prognosis of cryptococcosis explains the need for reliable tests. We evaluated the performances of a newly commercialized agglutination test that uses a monoclonal antibody specific for cryptococcal capsular polysaccharide (Pastorex Cryptococcus; Sanofi-Diagnostics Pasteur, Marnes-la-Coquette, France) and compared them with those of tests that use polyclonal immune sera (Cryptococcal Antigen Latex Agglutination System, Meridian Diagnostics, Inc., Cincinnati, Ohio; and Crypto-LA, International Biological Labs Inc., Cranbury, N.J.). The sensitivities and specificities of the tests were compared by using purified polysaccharides and yeast suspensions. Clinical specimens (131 serum samples, 41 cerebrospinal fluid samples, 34 urine samples, and 19 bronchoalveolar lavage samples) from 87 human immunodeficiency virus-positive subjects with (40 patients) and without (47 patients) culture-proven cryptococcosis were retrospectively tested during a blinded study. The effect of pronase treatment of samples was assessed for Pastorex Cryptococcus and the Cryptococcal Antigen Latex Agglutination System, and the antigen titers were compared. Our results show that (i) during the screening, concordance among the three tests was 97%; (ii) the use of pronase enhanced both the sensitivities and specificities of the Pastorex Cryptococcus test; (iii) titers agreed for 67% of the cerebrospinal fluid samples and 60% of the serum samples; and (iv) cryptococcosis was detected equally well with Pastorex Cryptococcus and with the other tests, whatever the infecting serotype (A, B, or D). The meaning of in vitro sensitivity and the relationship between titers and sensitivity are discussed. The results show that Pastorex Cryptococcus is a rapid and reliable test for the detection of cryptococcal antigen in body fluids and suggest that kits cannot be used interchangeably to monitor antigen titers in patients. PMID:1400951
Laboratory Evaluation of the Alere q Point-of-Care System for Early Infant HIV Diagnosis.
Hsiao, Nei-yuan; Dunning, Lorna; Kroon, Max; Myer, Landon
2016-01-01
Early infant diagnosis (EID) and prompt linkage to care are critical to minimise the high morbidity and mortality associated with infant HIV infection. Attrition in the "EID cascade" is common; however, point-of-care (POC) EID assays with same-day result could facilitate prompt linkage of HIV-infected infant to treatment. Despite a number of POC EID assays in development, few have been independently evaluated and data on new technologies are urgently needed to inform policy. We compared Alere q 1/2 Detect POC system laboratory test characteristics with the local standard of care (SOC), Roche CAP/CTM HIV-1 qualitative PCR in an independent laboratory-based evaluation in Cape Town, South Africa. Routinely EID samples collected between November 2013 and September 2014 were each tested by both SOC and POC systems. Repeat testing was done to troubleshoot any discrepancy between POC and SOC results. Overall, 1098 children with a median age of 47 days (IQR, 42-117) were included. Birth PCR (age <7 days) comprised of 8% (n = 92) tests while 56% (n = 620) of children tested as part of routine EID (ages 6-14 weeks). In the overall direct comparison, Alere q Detect achieved sensitivity of 95.5% (95% CI, 91.7-97.9%) and a specificity of 99.8% (95% CI, 99.1-100%). Following repeat testing of discordant samples and exclusion of any inconclusive results, the POC assay sensitivity and specificity were 96.9% (95% CI 93.4-98.9%) and 100% (lower 95% CI 98%) respectively. Among birth PCR tests the POC assay had slightly lower sensitivity (93.3% vs 96.5% in routine EID) and higher assay error rate (10% vs 5% in samples of older children, p = 0.04). Our results indicate this POC assay performs well for EID in the laboratory. The high specificity and thus high positive predictive value would suggest a positive POC result may be adequate for immediate infant ART initiation. While POC testing for EID may have particular utility for birth testing at delivery facilities, the lower sensitivity and error rate requires further attention, as does field implementation of POC EID technologies in other clinical care settings.
Pereira, Gilberto de Araujo; Louzada-Neto, Francisco; Barbosa, Valdirene de Fátima; Ferreira-Silva, Márcia Maria; de Moraes-Souza, Helio
2012-01-01
The frequent occurrence of inconclusive serology in blood banks and the absence of a gold standard test for Chagas'disease led us to examine the efficacy of the blood culture test and five commercial tests (ELISA, IIF, HAI, c-ELISA, rec-ELISA) used in screening blood donors for Chagas disease, as well as to investigate the prevalence of Trypanosoma cruzi infection among donors with inconclusive serology screening in respect to some epidemiological variables. To obtain estimates of interest we considered a Bayesian latent class model with inclusion of covariates from the logit link. A better performance was observed with some categories of epidemiological variables. In addition, all pairs of tests (excluding the blood culture test) presented as good alternatives for both screening (sensitivity > 99.96% in parallel testing) and for confirmation (specificity > 99.93% in serial testing) of Chagas disease. The prevalence of 13.30% observed in the stratum of donors with inconclusive serology, means that probably most of these are non-reactive serology. In addition, depending on the level of specific epidemiological variables, the absence of infection can be predicted with a probability of 100% in this group from the pairs of tests using parallel testing. The epidemiological variables can lead to improved test results and thus assist in the clarification of inconclusive serology screening results. Moreover, all combinations of pairs using the five commercial tests are good alternatives to confirm results.
Testing Conformance to Standards: Notes on the OGC CITE Initiative
NASA Astrophysics Data System (ADS)
Bigagli, Lorenzo; Vitale, Fabrizio
2010-05-01
In this work, we report on the issues and lessons learnt from our recent experience on assessing service compliance to OGC geospatial standards. Official conformity is warranted by the OGC Compliance & Interoperability Testing & Evaluation (CITE) initiative, through a centrally managed repository of tests, typically developed via initiatives funded by external sponsors. In particular, we have been involved in the ESA-led Heterogeneous Missions Accessibility Testbed (HMA-T) project. HMA-T objectives included the definition of specifications (and related compliance tests) for Earth Observation (EO) Product discovery and access. Our activities have focused on the EO and Catalogue of ISO Metadata (CIM) Extension Packages (EPs) of the ebRIM Application Profile (AP) of the Catalogue Service for the Web (CSW) OGC standard. Our main contributions have regarded the definition of Abstract Test Suites (ATS's) for the above specifications, as well as the development of Reference Implementations (RIs) and concrete Executable Test Suites (ETS's). According to the state-of-the-art, we have implemented the ETS's in Compliance Test Language (CTL), an OGC standard dialect of XML, and deployed the scripts onto the open-source Test Evaluation And Measurement (TEAM) Engine, the official OGC compliance test platform. A significant challenge was to accommodate legacy services, that can not support data publishing. Hence, we could not assume the presence of control test data, necessary for exhaustive assessment. To cope with this, we have proposed and experimented tests for assessing the internal coherence of a target service instance. Another issue was to assess the overall behavior of a target service instance. Although quite obvious, this requirement proved to be hard (if unviable) to implement, since the design of the OGC catalogue specification is multi-layered (i.e. comprised of EP, AP, binding and core functionalities) and, according to the current OGC rationale, ATS/ETS at each layer are supposed to only assess layer-specific functionalities. We argue that a sequence of individually correct "steps" may not result in an overall correct "route". In general, our experience suggests that an ATS is conveniently modeled as a multi-dimensional structure, in that compliance with a (multi-layered) specification may be partitioned into several orthogonal axes (e.g. operation, binding, data model). Hence, the correspondence between Abstract and Executable Test Cases (ATC, ETC, respectively) is not simply biunivocal, but generally an ATC maps to a number of ETCs (or to a single, "multi-modal" ETC), whose actual run-time behavior depend on the intended point of intersection of the ATS axes. This suggests possible benefits of an Aspect-Oriented extension of the ATC/ETC/CTL conceptual model. We identified several other open issues in the current CITE framework: noticeably, the lack of support for the test development phase (the design of the current tools seems more oriented to the certification use-case). Other results we obtained include: the definition of best practices for improved ETS/CTL documentation and the implementation of functionalities for its extraction and formatting; improvements to the readability of test logs and implementation of appropriate log consolidation functionalities in the TEAM Engine; comments and bug reports on the CSW 2.0.2 ETS. These results have been appropriately contributed to the relevant stakeholders. Besides, this work has provided us with new insights into the general OGC specification framework, particularly into the rationale for modular specifications.
Approach to evaluation and management of a patient with multiple food allergies.
Bird, J Andrew
2016-01-01
Diagnosing food allergy is often challenging, and validated testing modalities are mostly limited to immunoglobulin E (IgE)-mediated reactions to foods. Use of food-specific IgE tests and skin prick tests in individuals without a history that supports an IgE-mediated reaction to the specific food being tested diminishes the predictive capabilities of the test. To review the literature regarding evaluation of patients with a concern for multiple food allergies and to demonstrate an evidence-based approach to diagnosis and management. A literature search was performed and articles identified as relevant based on the search terms "food allergy," "food allergy diagnosis," "skin prick test," "serum IgE test," "oral food challenge", and "food allergy management." Patients at risk of food allergy are often misdiagnosed and appropriate evaluation of patients with concern for food allergy includes taking a thorough diet history and reaction history, performing specific tests intentionally and when indicated, and conducting an oral food challenge in a safe environment by an experienced provider when test results are inconclusive. An evidence-based approach to diagnosing and managing a patient at risk of having a life-threatening food allergy is reviewed.
An Evaluation of Different Statistical Targets for Assembling Parallel Forms in Item Response Theory
Ali, Usama S.; van Rijn, Peter W.
2015-01-01
Assembly of parallel forms is an important step in the test development process. Therefore, choosing a suitable theoretical framework to generate well-defined test specifications is critical. The performance of different statistical targets of test specifications using the test characteristic curve (TCC) and the test information function (TIF) was investigated. Test length, the number of test forms, and content specifications are considered as well. The TCC target results in forms that are parallel in difficulty, but not necessarily in terms of precision. Vice versa, test forms created using a TIF target are parallel in terms of precision, but not necessarily in terms of difficulty. As sometimes the focus is either on TIF or TCC, differences in either difficulty or precision can arise. Differences in difficulty can be mitigated by equating, but differences in precision cannot. In a series of simulations using a real item bank, the two-parameter logistic model, and mixed integer linear programming for automated test assembly, these differences were found to be quite substantial. When both TIF and TCC are combined into one target with manipulation to relative importance, these differences can be made to disappear.
Diagnostic Accuracy of the Neck Tornado Test as a New Screening Test in Cervical Radiculopathy
Park, Juyeon; Park, Woo Young; Hong, Seungbae; An, Jiwon; Koh, Jae Chul; Lee, Youn-Woo; Kim, Yong Chan; Choi, Jong Bum
2017-01-01
Background: The Spurling test, although a highly specific provocative test of the cervical spine in cervical radiculopathy (CR), has low to moderate sensitivity. Thus, we introduced the neck tornado test (NTT) to examine the neck and the cervical spine in CR. Objectives: The aim of this study was to introduce a new provocative test, the NTT, and compare the diagnostic accuracy with a widely accepted provocative test, the Spurling test. Design: Retrospective study. Methods: Medical records of 135 subjects with neck pain (CR, n = 67; without CR, n = 68) who had undergone cervical spine magnetic resonance imaging and been referred to the pain clinic between September 2014 and August 2015 were reviewed. Both the Spurling test and NTT were performed in all patients by expert examiners. Sensitivity, specificity, and accuracy were compared for both the Spurling test and the NTT. Results: The sensitivity of the Spurling test and the NTT was 55.22% and 85.07% (P < 0.0001); specificity, 98.53% and 86.76% (P = 0.0026); accuracy, 77.04% and 85.93% (P = 0.0423), respectively. Conclusions: The NTT is more sensitive with superior diagnostic accuracy for CR diagnosed by magnetic resonance imaging than the Spurling test. PMID:28824298
Giljaca, Vanja; Nadarevic, Tin; Poropat, Goran; Nadarevic, Vesna Stefanac; Stimac, Davor
2017-03-01
To determine the diagnostic accuracy of abdominal ultrasound (US) for the diagnosis of acute appendicitis (AA), in terms of sensitivity, specificity and post-test probabilities for positive and negative result. A systematic search of MEDLINE, Embase, The Cochrane library and Science Citation Index Expanded from January 1994 to October 2014 was performed. Two authors independently evaluated studies for inclusion, extracted data and performed analyses. The reference standard for evaluation of final diagnosis was pathohistological report on tissue obtained at appendectomy. Summary sensitivity, specificity and post-test probability of AA after positive and negative result of US with corresponding 95% confidence intervals (CI) were calculated. Out of 3306 references identified through electronic searches, 17 reports met the inclusion criteria, with 2841 included participants. The summary sensitivity and specificity of US for diagnosis of AA were 69% (95% CI 59-78%) and 81% (95% CI 73-88%), respectively. At the median pretest probability of AA of 76.4%, the post-test probability for a positive and negative result of US was 92% (95% CI 88-95%) and 55% (95% CI 46-63%), respectively. Abdominal ultrasound does not seem to have a role in the diagnostic pathway for diagnosis of AA in suspected patients. The summary sensitivity and specificity of US do not exceed that of physical examination. Patients that require additional diagnostic workup should be referred to more sensitive and specific diagnostic procedures, such as computed tomography.
Khanna, Ashish; Khanna, Menka; Gill, Karamjit Singh
2015-11-01
Typhoid fever remains a significant health problem in endemic countries like India. Various serological tests for the diagnosis of typhoid fever are available commercially. We assessed the usefulness of rapid test based on magnetic particle separation to detect Immunoglobulin against Salmonella typhi O9 lipopolysaccharide. Aim of this study was to compare the sensitivity and specificity of widal test, typhidot and tubex TF test for the diagnosis of typhoid fever in an endemic country like India. Serum samples collected from 50 patients of typhoid fever, 50 patients of non typhoid fever and 100 normal healthy individuals residing in Amritsar were subjected to widal test, typhidot test and tubex TF test as per manufacturer's instructions. Data collected was assessed to find sensitivity and specificity of these tests in an endemic area. Significant widal test results were found positive in 68% of patients of typhoid fever and only 4% of non typhoid fever patients. Typhidot (IgM or IgG) was positive in 72% of typhoid fever patients and 10% and 6% in non typhoid fever and normal healthy individuals respectively. Tubex TF showed higher sensitivity of 76% and specificity of 96-99% which was higher than typhidot and comparable to widal test. This was the first evaluation of rapid tubex TF test in northern India. In countries which can afford high cost of test, tubex TF should be recommended for the diagnosis in acute stage of the disease in clinical setting. However, there is urgent need for a highly specific and sensitive test for the diagnosis of typhoid fever in clinical settings in endemic areas.
Solarsh, Barbara; Alant, Erna
2006-01-01
A culturally appropriate test, The Test of Ability To Explain for Zulu-speaking Children (TATE-ZC), was developed to measure verbal problem solving skills of rural, Zulu-speaking, primary school children. Principles of 'non-biased' assessment, as well as emic (culture specific) and etic (universal) aspects of intelligence formed the theoretical backdrop. In addition, specific principles relating to test translation; test content; culturally appropriate stimulus material; scoring procedures and test administration were applied. Five categories of abstract thinking skills formed the basis of the TATE-ZC. These were: (a) Explaining Inferences, (b) Determining Cause, (c) Negative Why Questions, (d) Determining Solutions and (e) Avoiding Problem. The process of test development underwent three pilot studies. Results indicate that the TATE-ZC is a reliable and valid test for the target population. A critical analysis of the efficacy of creating a test of verbal reasoning for children from the developing world concludes the article. As a result of this activity (1) the participant will have a clearer understanding of the principles that need to be followed when developing culturally appropriate test material; (2) the participant will understand the process of developing culturally appropriate test material for non-mainstream cultures; (3) the participant will be able to apply the process and principles to other cross-cultural testing situations.
Field evaluation of a malaria rapid diagnostic test (ICT Pf).
Moonasar, Devanand; Goga, Ameena E; Kruger, Philip S; La Cock, Christine; Maharaj, Rajendra; Frean, John; Chandramohan, Daniel
2009-11-01
Malaria rapid diagnostic tests (MRDTs) are quick and easy to perform and useful for diagnosing malaria in primary health care settings. In South Africa most malaria infections are due to Plasmodium falciparurrm, and HRPII-based MRDTs have been used since 2001. Previous studies in Africa showed variability in sensitivity and specificity of HRPII-based MRDTs; hence, we conducted a field evaluation in Limpopo province to determine the accuracy of the MRDT currently used in public sector clinics and hospitals. A cross-sectional observational study was conducted to determine the sensitivity and specificity of an ICT Pf MRDT. We tested 405 patients with fever with ICT Pf MRDT and compared the results with blood film microscopy (the gold standard). RESULTS. The overall sensitivity of the ICT Pf MRDT was 99.48% (95% confidence interval (CI) 96.17-100%), while specificity was 96.26% (95% CI 94.7-100%). The positive predictive value of the test was 98.48 (99% CI 98.41-100%), and the negative predictive value was 99.52% (95% CI 96.47-100%). The ICT Pf MRDT is an appropriate test to use in the field in South Africa where laboratory facilities are not available. It has a high degree of sensitivity and acceptable level of specificity in accordance with the World Health Organization criteria. However, sensitivity of MRDT at low levels of parasitaemia (<100 parasites/microl of blood) in field conditions must still be established.
... pathology report will include the results of these tests. For example, the pathology report may include information obtained from ... markers or indicators of a specific cancer. For example, the Philadelphia chromosome ... ( 3 ). Some tests that might be performed on a tissue sample ...
NASA Technical Reports Server (NTRS)
1981-01-01
The development of several types of graphite/polyimide (GR/PI) bonded and bolted joints is reported. The program consists of two concurrent tasks: (1) design and test of specific built up attachments; and (2) evaluation of standard advanced bonded joint concepts. A data base for the design and analysis of advanced composite joints for use at elevated temperatures (561K (550 deg F)) to design concepts for specific joining applications, and the fundamental parameters controlling the static strength characteristics of such joints are evaluated. Data for design and build GR/PI of lightly loaded flight components for advanced space transportation systems and high speed aircraft are presented. Results for compression and interlaminar shear strengths of Celion 6000/PMR-15 laminates are given. Static discriminator test results for type 3 and type 4 bonded and bolted joints and final joint designs for TASK 1.4 scale up fabrication and testing are presented.
NASA Technical Reports Server (NTRS)
Haigh, R.; Krimchansky, S. (Technical Monitor)
2000-01-01
This is the Performance Verification Report, METSAT (S/N 108) AMSU-A1 Receiver Assemblies P/N 1356429-1 S/N F05 and P/N 1356409-1 S/N F05, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A). The ATP for the AMSU-A Receiver Subsystem, AE-26002/6A, is prepared to describe in detail the configuration of the test setups and the procedures of the tests to verify that the receiver subsystem meets the specifications as required either in the AMSU-A Instrument Performance and Operation Specifications, S-480-80, or in AMSU-A Receiver Subsystem Specifications, AE-26608, derived by the Aerojet System Engineering. Test results that verify the conformance to the specifications demonstrate the acceptability of that particular receiver subsystem.
Page, Iain D; Richardson, Malcolm D; Denning, David W
2016-02-01
Chronic pulmonary aspergillosis (CPA) is estimated to affect 3 million persons worldwide. Aspergillus-specific IgG is a key component in CPA diagnosis. We aimed to establish the optimal diagnostic cut offs for CPA and the comparative performance of six assays in this context. Sera from 241 patients with CPA and 100 healthy blood donors were tested using five Aspergillus-specific IgG assays plus precipitin testing using Microgen Aspergillus antigens. Receiver operating characteristic (ROC) curve area under the curve (AUC) results were as follows: ThermoFisher Scientific ImmunoCAP 0.996 (95% confidence interval 0.992-1), Siemens Immulite 0.991 (0.982-1), Serion 0.973 (0.960-0.987), Dynamiker 0.918 (0.89-0.946) and Genesis 0.902 (0.871-0.933). Optimal CPA diagnostic cut-offs were; ImmunoCAP 20 mg/L (96% sensitivity, 98% specificity), Immulite 10 mg/L (96% sensitivity, 98% specificity), Serion 35 U/ml (90% sensitivity, 98% specificity), Dynamiker 65 AU/ml (77% sensitivity, 97% specificity) and Genesis 20 U/ml (75% sensitivity, 99% specificity). The precipitin test was 59% sensitive and 100% specific. ImmunoCAP and Immulite were statistically significantly superior to the other assays. Precipitins testing performed poorly. The currently accepted ImmunoCAP cut-off of 40 mg/L appears sub-optimal for CPA diagnosis and may require revision in this context. Copyright © 2015 The British Infection Association. Published by Elsevier Ltd. All rights reserved.
Corona-Strauss, Farah I.; Schick, Bernhard; Delb, Wolfgang; Strauss, Daniel J.
2012-01-01
It has been shown recently that chirp-evoked auditory brainstem responses (ABRs) show better performance than click stimulations, especially at low intensity levels. In this paper we present the development, test, and evaluation of a series of notched-noise embedded frequency specific chirps. ABRs were collected in healthy young control subjects using the developed stimuli. Results of the analysis of the corresponding ABRs using a time-scale phase synchronization stability (PSS) measure are also reported. The resultant wave V amplitude and latency measures showed a similar behavior as for values reported in literature. The PSS of frequency specific chirp-evoked ABRs reflected the presence of the wave V for all stimulation intensities. The scales that resulted in higher PSS are in line with previous findings, where ABRs evoked by broadband chirps were analyzed, and which stated that low frequency channels are better for the recognition and analysis of chirp-evoked ABRs. We conclude that the development and test of the series of notched-noise embedded frequency specific chirps allowed the assessment of frequency specific ABRs, showing an identifiable wave V for different intensity levels. Future work may include the development of a faster automatic recognition scheme for these frequency specific ABRs. PMID:26557336
Wall and corner fire tests on selected wood products
H. C. Tran; M. L. Janssens
1991-01-01
As part of a fire growth program to develop and validate a compartment fire model, several bench-scale and full-scale tests were conducted. This paper reports the full-scale wall and corner test results of step 2 of this study. A room fire test following the ASTM proposed standard specifications was used for these full-scale tests. In step 1, we investigated the...
Physical and chemical test results of electrostatic safe flooring materials
NASA Technical Reports Server (NTRS)
Gompf, R. H.
1988-01-01
This test program was initiated because a need existed at the Kennedy Space Center (KSC) to have this information readily available to the engineer who must make the choice of which electrostatic safe floor to use in a specific application. The information, however, should be of value throughout both the government and private industry in the selection of a floor covering material. Included are the test results of 18 floor covering materials which by test evaluation at KSC are considered electrostatically safe. Tests were done and/or the data compiled in the following areas: electrostatics, flammability, hypergolic compatibility, outgassing, floor type, material thickness, and available colors. Each section contains the test method used to gather the data and the test results.
2013-01-01
Background The extent to which a genomic test will be used in practice is affected by factors such as ability of the test to correctly predict response to treatment (i.e. sensitivity and specificity of the test), invasiveness of the testing procedure, test cost, and the probability and severity of side effects associated with treatment. Methods Using discrete choice experimentation (DCE), we elicited preferences of the public (Sample 1, N = 533 and Sample 2, N = 525) and cancer patients (Sample 3, N = 38) for different attributes of a hypothetical genomic test for guiding cancer treatment. Samples 1 and 3 considered the test/treatment in the context of an aggressive curable cancer (scenario A) while the scenario for sample 2 was based on a non-aggressive incurable cancer (scenario B). Results In aggressive curable cancer (scenario A), everything else being equal, the odds ratio (OR) of choosing a test with 95% sensitivity was 1.41 (versus a test with 50% sensitivity) and willingness to pay (WTP) was $1331, on average, for this amount of improvement in test sensitivity. In this scenario, the OR of choosing a test with 95% specificity was 1.24 times that of a test with 50% specificity (WTP = $827). In non-aggressive incurable cancer (scenario B), the OR of choosing a test with 95% sensitivity was 1.65 (WTP = $1344), and the OR of choosing a test with 95% specificity was 1.50 (WTP = $1080). Reducing severity of treatment side effects from severe to mild was associated with large ORs in both scenarios (OR = 2.10 and 2.24 in scenario A and B, respectively). In contrast, patients had a very large preference for 95% sensitivity of the test (OR = 5.23). Conclusion The type and prognosis of cancer affected preferences for genomically-guided treatment. In aggressive curable cancer, individuals emphasized more on the sensitivity rather than the specificity of the test. In contrast, for a non-aggressive incurable cancer, individuals put similar emphasis on sensitivity and specificity of the test. While the public expressed strong preference toward lowering severity of side effects, improving sensitivity of the test had by far the largest influence on patients’ decision to use genomic testing. PMID:24176050
Use of Specific IgE and Skin Prick Test to Determine Clinical Reaction Severity
Ta, Von; Weldon, Brittany; Yu, Grace; Humblet, Olivier; Neale-May, Susan; Nadeau, Kari
2012-01-01
Aims To determine whether specific IgE and skin prick test correlate better in predicting reaction severity during a double-blinded placebo controlled food challenge (DBPCFC) for egg, milk, and multiple tree nut allergens. Study design Prospective study. Place and Duration of Study Department of Pediatrics, Stanford University School of Medicine, August 2009 and ongoing. Methodology We examined the reaction severity of twenty-four subjects to nine possible food allergens: milk, egg, almond, cashew, hazelnut, peanut, sesame, pecan and walnut. Specific IgE and SPT were performed before each DBPCFC. DBPCFC results were classified into mild (1), moderate (2), or severe (3) reactions using a modified Bock’s criteria. Results Twenty four subjects underwent a total of 80 DBPCFC. Eighty percent of all DBPCFCs resulted in a positive reaction. A majority, 71%, were classified as mild. No reactions occurred with a SPT of zero mm while three reactions occurred with a negative specific IgE. All reactions were reversible with medication. Conclusion These data suggest that SPT and specific IgE levels are not associated with reaction severity (p<0.64 and 0.27, respectively). We also found that combining specific IgE and SPT improved specificity but did not help to achieve clinically useful sensitivity. For instance, an SPT > 5mm had a sensitivity of 91% and specificity of 50%. Combining SPT > 5mm and IgE > 7 resulted in a reduced sensitivity of 64%. Unexpectedly, a history of anaphylaxis 70% (n=17) was not predictive of anaphylaxis on challenge 4% (n=2). PMID:22993721
Kothe, Christian; Hissbach, Johanna; Hampe, Wolfgang
2013-01-01
Introduction: The present study examines the question whether the selection of dental students should be based solely on average school-leaving grades (GPA) or whether it could be improved by using a subject-specific aptitude test. Methods: The HAM-Nat Natural Sciences Test was piloted with freshmen during their first study week in 2006 and 2007. In 2009 and 2010 it was used in the dental student selection process. The sample size in the regression models varies between 32 and 55 students. Results: Used as a supplement to the German GPA, the HAM-Nat test explained up to 12% of the variance in preclinical examination performance. We confirmed the prognostic validity of GPA reported in earlier studies in some, but not all of the individual preclinical examination results. Conclusion: The HAM-Nat test is a reliable selection tool for dental students. Use of the HAM-Nat yielded a significant improvement in prediction of preclinical academic success in dentistry. PMID:24282449
Landsbergen, K M; Prins, J B; Brunner, H G; van Duijvendijk, P; Nagengast, F M; van Krieken, J H; Ligtenberg, M; Hoogerbrugge, N
2012-06-01
According to the Dutch Guideline on Hereditary Colorectal Cancer published in 2008, patients with recently diagnosed colorectal cancer (CRC) should undergo microsatellite instability (MSI) testing by a pathologist immediately after tumour resection if they are younger than 50 years, or if a second CRC has been diagnosed before the age of 70 years, owing to the high risk of Lynch syndrome (MIPA). The aim of the present MIPAPS study was to investigate general distress and cancer-specific distress following MSI testing. From March 2007 to September 2009, 400 patients who had been tested for MSI after newly diagnosed CRC were recruited from 30 Dutch hospitals. Levels of general distress (SCL-90) and cancer-specific distress (IES) were assessed immediately after MSI result disclosure (T1) and 6 months later (T2). Response rates were 23/77 (30%) in the MSI-positive patients and 58/323 (18%) in the MSI-negative patients. Levels of general distress and cancer-specific distress were moderate. In the MSI-positive group, 27% of the patients had high general distress at T1 versus 18% at T2 (p = 0.5), whereas in the MSI-negative group, these percentage were 14 and 18% (p = 0.6), respectively. At T1 and T2, cancer-specific distress rates in the MSI-positive group and MSI-negative group were 39 versus 27% (p = 0.3) and 38 versus 36% (p = 1.0), respectively. High levels of general distress were correlated with female gender, low social support and high perceived cancer risk. Moderate levels of distress were observed after MSI testing, similar to those found in other patients diagnosed with CRC. Immediately after result disclosure, high cancer-specific distress was observed in 40% of the MSI-positive patients.
2011-01-01
Background Simian Immunodeficiency Viruses (SIVs) are the precursors of Human Immunodeficiency Viruses (HIVs) which have lead to the worldwide HIV/AIDS pandemic. By studying SIVs in wild primates we can better understand the circulation of these viruses in their natural hosts and habitat, and perhaps identify factors that influence susceptibility and transmission within and between various host species. We investigated the SIV status of wild West African chimpanzees (Pan troglodytes verus) which frequently hunt and consume the western red colobus monkey (Piliocolobus badius badius), a species known to be infected to a high percentage with its specific SIV strain (SIVwrc). Results Blood and plasma samples from 32 wild chimpanzees were tested with INNO-LIA HIV I/II Score kit to detect cross-reactive antibodies to HIV antigens. Twenty-three of the samples were also tested for antibodies to 43 specific SIV and HIV lineages, including SIVwrc. Tissue samples from all but two chimpanzees were tested for SIV by PCRs using generic SIV primers that detect all known primate lentiviruses as well as primers designed to specifically detect SIVwrc. Seventeen of the chimpanzees showed varying degrees of cross-reactivity to the HIV specific antigens in the INNO-LIA test; however no sample had antibodies to SIV or HIV strain - and lineage specific antigens in the Luminex test. No SIV DNA was found in any of the samples. Conclusions We could not detect any conclusive trace of SIV infection from the red colobus monkeys in the chimpanzees, despite high exposure to this virus through frequent hunting. The results of our study raise interesting questions regarding the host-parasite relationship of SIVwrc and wild chimpanzees in their natural habitat. PMID:21284842
Helicobacter pylori diagnostic tests in children: review of the literature from 1999 to 2009.
Guarner, Jeannette; Kalach, Nicolas; Elitsur, Yoram; Koletzko, Sibylle
2010-01-01
The array of tests that can be used for diagnosis of Helicobacter pylori infection is large, and it can be confusing to define which test to use particularly in children where results may not be comparable to those obtained in adult patients. Using PubMed, we reviewed the English literature from January 1999 to May 2009 to identify articles that determined sensitivity and specificity of H. pylori invasive and non-invasive diagnostic tests in children. We excluded articles that presented a review of the literature, abstracts, case reports, or series where children's results could not be separated from adult populations. Of the tissue based methods, rapid urease tests have better sensitivity than histology to detect presence of H. pylori; however, histology can detect the pathology associated with disease including gastritis, intestinal metaplasia, and other conditions that could be the cause of the child's symptoms. Culture of gastric tissues or stool has 100% specificity but sensitivity is low. Of the serologic tests, immunoblot has the best sensitivity. The urea breath tests have >75% sensitivity for detection of H. pylori before and after treatment. Immunoassays in stool using monoclonal antibodies have >95% sensitivity for detection of H. pylori before and after treatment. PCR testing can be performed in tissue and stool samples and can detect genes associated to antibiotic resistance. In summary, the current commercial non-invasive tests have adequate sensitivity and specificity for detecting the presence of H. pylori; however, endoscopy with histopathology is the only method that can detect H. pylori and lesions associated with the infection.
Danišová, Olga; Halánová, Monika; Valenčáková, Alexandra; Luptáková, Lenka
The study was conducted to compare the specificity of immunological diagnostic methods used for the diagnosis of Cryptosporidium species capable of causing life-threatening infection in both immunosuppressed and immunocompetent patients. For the detection of Cryptosporidium species in 79 animals with diarrhoea, we used three Copro-antigen tests: RIDASCREEN ® Cryptosporidium test, Cryptosporidium 2nd Generation (ELISA) and RIDA ® QUICK Cryptosporidium. For immunoassays we used positive and negative samples detected by means of polymerase chain reaction and validated by sequencing and nested polymerase chain reaction to confirm the presence six different species of Cryptosporidium species. Prevalence of cryptosporidiosis in the entire group determined by enzyme immunoassay, enzyme linked immunosorbent assay, immuno-chromatographic test and polymerase chain reaction was 34.17%, 27.84%, 6.33% and 27.84%, respectively. Sensitivity of animal samples with enzyme immunoassay, enzyme linked immunosorbent assay, and immuno-chromatographic test was 63.6%, 40.9% and 22.7%, resp., when questionable samples were considered positive, whereas specificity of enzyme immunoassay, enzyme linked immunosorbent assay and immuno-chromatographic test was 75.9%, 78.9% and 100%, respectively. Positive predictive values and negative predictive values were different for all the tests. These differences results are controversial and therefore reliability and reproducibility of immunoassays as the only diagnostic method is questionable. The use of various Cryptosporidium species in diagnosis based on immunological testing and different results obtained by individual tests indicate potential differences in Copro-antigens produced by individual Cryptosporidium species. Copyright © 2017 Sociedade Brasileira de Microbiologia. Published by Elsevier Editora Ltda. All rights reserved.
Physical examination for lumbar radiculopathy due to disc herniation in patients with low-back pain.
van der Windt, Daniëlle Awm; Simons, Emmanuel; Riphagen, Ingrid I; Ammendolia, Carlo; Verhagen, Arianne P; Laslett, Mark; Devillé, Walter; Deyo, Rick A; Bouter, Lex M; de Vet, Henrica Cw; Aertgeerts, Bert
2010-02-17
Low-back pain with leg pain (sciatica) may be caused by a herniated intervertebral disc exerting pressure on the nerve root. Most patients will respond to conservative treatment, but in carefully selected patients, surgical discectomy may provide faster relief of symptoms. Primary care clinicians use patient history and physical examination to evaluate the likelihood of disc herniation and select patients for further imaging and possible surgery. (1) To assess the performance of tests performed during physical examination (alone or in combination) to identify radiculopathy due to lower lumbar disc herniation in patients with low-back pain and sciatica;(2) To assess the influence of sources of heterogeneity on diagnostic performance. We searched electronic databases for primary studies: PubMed (includes MEDLINE), EMBASE, and CINAHL, and (systematic) reviews: PubMed and Medion (all from earliest until 30 April 2008), and checked references of retrieved articles. We considered studies if they compared the results of tests performed during physical examination on patients with back pain with those of diagnostic imaging (MRI, CT, myelography) or findings at surgery. Two review authors assessed the quality of each publication with the QUADAS tool, and extracted details on patient and study design characteristics, index tests and reference standard, and the diagnostic two-by-two table. We presented information on sensitivities and specificities with 95% confidence intervals (95% CI) for all aspects of physical examination. Pooled estimates of sensitivity and specificity were computed for subsets of studies showing sufficient clinical and statistical homogeneity. We included 16 cohort studies (median N = 126, range 71 to 2504) and three case control studies (38 to100 cases). Only one study was carried out in a primary care population. When used in isolation, diagnostic performance of most physical tests (scoliosis, paresis or muscle weakness, muscle wasting, impaired reflexes, sensory deficits) was poor. Some tests (forward flexion, hyper-extension test, and slump test) performed slightly better, but the number of studies was small. In the one primary care study, most tests showed higher specificity and lower sensitivity compared to other settings.Most studies assessed the Straight Leg Raising (SLR) test. In surgical populations, characterized by a high prevalence of disc herniation (58% to 98%), the SLR showed high sensitivity (pooled estimate 0.92, 95% CI: 0.87 to 0.95) with widely varying specificity (0.10 to 1.00, pooled estimate 0.28, 95% CI: 0.18 to 0.40). Results of studies using imaging showed more heterogeneity and poorer sensitivity. The crossed SLR showed high specificity (pooled estimate 0.90, 95% CI: 0.85 to 0.94) with consistently low sensitivity (pooled estimate 0.28, 95% CI: 0.22 to 0.35).Combining positive test results increased the specificity of physical tests, but few studies presented data on test combinations. When used in isolation, current evidence indicates poor diagnostic performance of most physical tests used to identify lumbar disc herniation. However, most findings arise from surgical populations and may not apply to primary care or non-selected populations. Better performance may be obtained when tests are combined.
Qiao, H-L; Li, Z; Yang, J; Tian, X; Gao, N; Jia, L-J
2009-06-01
Although skin tests are usually employed to evaluate current penicillin allergy status, a negative result does not exclude hypersensitivity. There is a need for accurate in vitro tests to exclude hypersensitivity. A radioallergosorbent test (RAST) is a potentially good supplementary approach, but there is little information on the suitability of this method to diagnose penicillin hypersensitivity in subjects with a negative skin test to benzylpenicillin. A total of 133 patients with a negative skin test to benzylpenicillin G (PG) and all of whom developed allergic reactions to PG were studied. RAST was used to detect eight kinds of specific IgE antibodies to penicillins in serum, which included four kinds of major and minor antigenic determinants to four penicillin drugs. The combination sites for the specific IgE antibodies were studied by RAST inhibition test. The rate of positive reactions for the specific IgE antibodies was 59.40% (79/133). Of the eight kinds of antigenic determinants, the positive rates for specific IgE against the major and minor determinants were 39.10% (52) and 42.86% (57) respectively. Of the four drugs, positive cases only to PG were 10 (7.5%), were significantly fewer than the cross-reacting positive cases (36) to PG (P < 0.01). In the RAST inhibition studies all drugs exhibited good inhibitory potencies, and in some instances the side-chain of the penicillins could induce specific responses with a variable degree of cross-reactivity among the different penicillins. Radioallergosorbent test is a good complementary test in persons who are skin-test negative with PG, and the sensitivity of RAST increases with increasing specificity of IgE antibodies to be detected. 6-APA and the groups, making part of the different side-chains on penicillins, all contributed to the cross-reactivity.
Delorey, Mark J.; Replogle, Adam; Sexton, Christopher; Schriefer, Martin E.
2017-01-01
ABSTRACT The recommended laboratory diagnostic approach for Lyme disease is a standard two-tiered testing (STTT) algorithm where the first tier is typically an enzyme immunoassay (EIA) that if positive or equivocal is reflexed to Western immunoblotting as the second tier. bioMérieux manufactures one of the most commonly used first-tier EIAs in the United States, the combined IgM/IgG Vidas test (LYT). Recently, bioMérieux launched its dissociated first-tier tests, the Vidas Lyme IgM II (LYM) and IgG II (LYG) EIAs, which use purified recombinant test antigens and a different algorithm than STTT. The dissociated LYM/LYG EIAs were evaluated against the combined LYT EIA using samples from 471 well-characterized Lyme patients and controls. Statistical analyses were conducted to assess the performance of these EIAs as first-tier tests and when used in two-tiered algorithms, including a modified two-tiered testing (MTTT) approach where the second-tier test was a C6 EIA. Similar sensitivities and specificities were obtained for the two testing strategies (LYT versus LYM/LYG) when used as first-tier tests (sensitivity, 83 to 85%; specificity, 85 to 88%) with an observed agreement of 80%. Sensitivities of 68 to 69% and 76 to 77% and specificities of 97% and 98 to 99% resulted when the two EIA strategies were followed by Western immunoblotting and when used in an MTTT, respectively. The MTTT approach resulted in significantly higher sensitivities than did STTT. Overall, the LYM/LYG EIAs performed equivalently to the LYT EIA in test-to-test comparisons or as first-tier assays in STTT or MTTT with few exceptions. PMID:28330884
Branda, John A; Aguero-Rosenfeld, Maria E; Ferraro, Mary Jane; Johnson, Barbara J B; Wormser, Gary P; Steere, Allen C
2010-01-01
Standard 2-tiered immunoglobulin G (IgG) testing has performed well in late Lyme disease (LD), but IgM testing early in the illness has been problematic. IgG VlsE antibody testing, by itself, improves early sensitivity, but may lower specificity. We studied whether elements of the 2 approaches could be combined to produce a second-tier IgG blot that performs well throughout the infection. Separate serum sets from LD patients and control subjects were tested independently at 2 medical centers using whole-cell enzyme immunoassays and IgM and IgG immunoblots, with recombinant VlsE added to the IgG blots. The results from both centers were combined, and a new second-tier IgG algorithm was developed. With standard 2-tiered IgM and IgG testing, 31% of patients with active erythema migrans (stage 1), 63% of those with acute neuroborreliosis or carditis (stage 2), and 100% of those with arthritis or late neurologic involvement (stage 3) had positive results. Using new IgG criteria, in which only the VlsE band was scored as a second-tier test among patients with early LD (stage 1 or 2) and 5 of 11 IgG bands were required in those with stage 3 LD, 34% of patients with stage 1, 96% of those with stage 2, and 100% of those with stage 3 infection had positive responses. Both new and standard testing achieved 100% specificity. Compared with standard IgM and IgG testing, the new IgG algorithm (with VlsE band) eliminates the need for IgM testing; it provides comparable or better sensitivity, and it maintains high specificity.
The advisability of prototypic testing for space nuclear systems
NASA Astrophysics Data System (ADS)
Lenard, Roger X.
2005-07-01
From October 1987 until 1993, the US Department of Defense conducted the Space Nuclear Thermal Propulsion program. This program's objective was to design and develop a high specific impulse, high thrust-to-weight nuclear thermal rocket engine for upper stage applications. The author was the program manager for this program until 1992. Numerous analytical, programmatic and experimental results were generated during this period of time. This paper reviews the accomplishments of the program and highlights the importance of prototypic testing for all aspects of a space nuclear program so that a reliable and safe system compliant with all regulatory requirements can be effectively engineered. Specifically, the paper will recount how many non-prototypic tests we performed only to have more representative tests consistently generate different results. This was particularly true in area of direct nuclear heat generation. As nuclear tests are generally much more expensive than non-nuclear tests, programs attempt to avoid such tests in favor of less expensive non-nuclear tests. Each time this approach was followed, the SNTP program found these tests to not be verified by nuclear heated testing. Hence the author recommends that wherever possible, a spiral development approach that includes exploratory and confirmatory experimental testing be employed to ensure a viable design.
An evaluation of the SD Bioline HIV/syphilis duo test.
Holden, Jeffrey; Goheen, Joshua; Jett-Goheen, Mary; Barnes, Mathilda; Hsieh, Yu-Hsiang; Gaydos, Charlotte A
2018-01-01
Many health agencies now recommend routine HIV and syphilis testing for pregnant women and most-at-risk populations such as men who have sex with men. With the increased availability of highly sensitive, low cost rapid point-of-care tests, the ability to meet those recommendations has increased, granting wider access to quick and accurate diagnoses. Using blood specimens collected from a Baltimore City Health Department (BCHD) sexually transmitted infection clinic, we evaluated the SD Bioline HIV/Syphilis Duo, a rapid test that simultaneously detects antibodies to HIV and syphilis and has the potential to further benefit clinics and patients by reducing costs, testing complexity, and patient wait times. SD DUO HIV sensitivity and specificity, when compared to BCHD results, were 91.7 and 99.5%, respectively. SD DUO syphilis sensitivity and specificity, when compared to rapid plasma reagin, were 85.7 and 96.8%, respectively, and 69.7 and 99.7%, respectively, when compared to Treponema pallidum particle agglutination (TPPA). SD DUO syphilis sensitivity and specificity, when compared to a traditional screening algorithm, improved to 92.3 and 100%, respectively, and improved to 72.9 and 99.7%, respectively, when compared to a reverse screening algorithm. The HIV component of the SD DUO performed moderately well. However, results for the SD DUO syphilis component, when compared to TPPA, support the need for further testing and assessment.
2011-01-01
Background The botanical relation between grass and cereal grains may be relevant when diagnosing food allergy to cereals. The aim was to investigate the diagnostic specificity of skin prick test (SPT) and specific immunoglobulin E (sIgE) tests to cereals and peanut in grass pollen allergic subjects without history of, and clinically reactions to foods botanically related to grass. Methods 70 subjects (41 females; mean age 32 years) and 20 healthy controls (13 females; mean age 24 years) were tested by open food challenge (OFC) with cereals and peanut. SPT and sIgE both with Immulite® (Siemens) and ImmunoCAP® (Phadia) to grass and birch pollen, cereals, peanut and bromelain were performed. Results Of the 65 OFC-negative subjects 29-46% (SPT, depending on cut-off), 20% (Immulite) and 38% (ImmunoCAP) had positive results to one or more of the foods tested. Controls were negative in all tests. Cross-reactive carbohydrate determinants (CCD) as evidenced by reaction to bromelain could explain only a minority of the measured IgE-sensitizations. Conclusion Grass pollen allergic patients with documented food tolerance to cereals and peanut may express significant sensitization. False-positive cereal or peanut allergy diagnoses may be a quantitatively important problem both in routine clinical work and epidemiological studies. PMID:22409998
Towards sensible toxicity testing for nanomaterials: proposal for the specification of test design
NASA Astrophysics Data System (ADS)
Potthoff, Annegret; Weil, Mirco; Meißner, Tobias; Kühnel, Dana
2015-12-01
During the last decade, nanomaterials (NM) were extensively tested for potential harmful effects towards humans and environmental organisms. However, a sound hazard assessment was so far hampered by uncertainties and a low comparability of test results. The reason for the low comparability is a high variation in the (1) type of NM tested with regard to raw material, size and shape and (2) procedures before and during the toxicity testing. This calls for tailored, nanomaterial-specific protocols. Here, a structured approach is proposed, intended to lead to test protocols not only tailored to specific types of nanomaterials, but also to respective test system for toxicity testing. There are existing standards on single procedures involving nanomaterials, however, not all relevant procedures are covered by standards. Hence, our approach offers a detailed way of weighting several plausible alternatives for e.g. sample preparation, in order to decide on the procedure most meaningful for a specific nanomaterial and toxicity test. A framework of several decision trees (DT) and flow charts to support testing of NM is proposed as a basis for further refinement and in-depth elaboration. DT and flow charts were drafted for (1) general procedure—physicochemical characterisation, (2) choice of test media, (3) decision on test scenario and application of NM to liquid media, (4) application of NM to the gas phase, (5) application of NM to soil and sediments, (6) dose metrics, (S1) definition of a nanomaterial, and (S2) dissolution. The applicability of the proposed approach was surveyed by using experimental data retrieved from studies on nanoscale CuO. This survey demonstrated the DT and flow charts to be a convenient tool to systematically decide upon test procedures and processes, and hence pose an important step towards harmonisation of NM testing.
Towards sensible toxicity testing for nanomaterials: proposal for the specification of test design.
Potthoff, Annegret; Weil, Mirco; Meißner, Tobias; Kühnel, Dana
2015-12-01
During the last decade, nanomaterials (NM) were extensively tested for potential harmful effects towards humans and environmental organisms. However, a sound hazard assessment was so far hampered by uncertainties and a low comparability of test results. The reason for the low comparability is a high variation in the (1) type of NM tested with regard to raw material, size and shape and (2) procedures before and during the toxicity testing. This calls for tailored, nanomaterial-specific protocols. Here, a structured approach is proposed, intended to lead to test protocols not only tailored to specific types of nanomaterials, but also to respective test system for toxicity testing. There are existing standards on single procedures involving nanomaterials, however, not all relevant procedures are covered by standards. Hence, our approach offers a detailed way of weighting several plausible alternatives for e.g. sample preparation, in order to decide on the procedure most meaningful for a specific nanomaterial and toxicity test. A framework of several decision trees (DT) and flow charts to support testing of NM is proposed as a basis for further refinement and in-depth elaboration. DT and flow charts were drafted for (1) general procedure-physicochemical characterisation, (2) choice of test media, (3) decision on test scenario and application of NM to liquid media, (4) application of NM to the gas phase, (5) application of NM to soil and sediments, (6) dose metrics, (S1) definition of a nanomaterial, and (S2) dissolution. The applicability of the proposed approach was surveyed by using experimental data retrieved from studies on nanoscale CuO. This survey demonstrated the DT and flow charts to be a convenient tool to systematically decide upon test procedures and processes, and hence pose an important step towards harmonisation of NM testing.
Validation of 2 commercial Neospora caninum antibody enzyme linked immunosorbent assays
Wu, John T.Y.; Dreger, Sally; Chow, Eva Y.W.; Bowlby, Evelyn E.
2002-01-01
Abstract This is a validation study of 2 commercially available enzyme linked immunosorbent assays (ELISA) for the detection of antibodies against Neospora caninum in bovine serum. The results of the reference sera (n = 30) and field sera from an infected beef herd (n = 150) were tested by both ELISAs and the results were compared statistically. When the immunoblotting results of the reference bovine sera were compared to the ELISA results, the same identity score (96.67%) and kappa values (K) (0.93) were obtained for both ELISAs. The sensitivity and specificity values for the IDEXX test were 100% and 93.33% respectively. For the Biovet test 93.33% and 100% were obtained. The corresponding positive (PV+) and negative predictive (PV−) values for the 2 assays were 93.75% and 100% (IDEXX), and 100% and 93.75% (Biovet). In the 2nd study, competitive inhibition ELISA (c-ELISA) results on bovine sera from an infected herd were compared to the 2 sets of ELISA results. The identity scores of the 2 ELISAs were 98% (IDEXX) and 97.33% (Biovet). The K values calculated were 0.96 (IDEXX) and 0.95 (Biovet). For the IDEXX test the sensitivity and specificity were 97.56% and 98.53%, whereas for the Biovet assay 95.12% and 100% were recorded, respectively. The corresponding PV+ and PV− values were 98.77% and 97.1% (IDEXX), and 100% and 94.44% (Biovet). Our validation results showed that the 2 ELISAs worked equally well and there was no statistically significant difference between the performance of the 2 tests. Both tests showed high reproducibility, repeatability and substantial agreement with results from 2 other laboratories. A quality assurance based on the requirement of the ISO/IEC 17025 standards has been adopted throughout this project for test validation procedures. PMID:12418782