Prostate-specific antigen lowering effect of metabolic syndrome is influenced by prostate volume.
Choi, Woo Suk; Heo, Nam Ju; Paick, Jae-Seung; Son, Hwancheol
2016-04-01
To investigate the influence of metabolic syndrome on prostate-specific antigen levels by considering prostate volume and plasma volume. We retrospectively analyzed 4111 men who underwent routine check-ups including prostate-specific antigen and transrectal ultrasonography. The definition of metabolic syndrome was based on the modified Adult Treatment Panel III criteria. Prostate-specific antigen mass density (prostate-specific antigen × plasma volume / prostate volume) was calculated for adjusting plasma volume and prostate volume. We compared prostate-specific antigen and prostate-specific antigen mass density levels of participants with metabolic syndrome (metabolic syndrome group, n = 1242) and without metabolic syndrome (non-prostate-specific antigen metabolic syndrome group, n = 2869). To evaluate the impact of metabolic syndrome on prostate-specific antigen, linear regression analysis for the natural logarithm of prostate-specific antigen was used. Patients in the metabolic syndrome group had significantly older age (P < 0.001), larger prostate volume (P < 0.001), higher plasma volume (P < 0.001) and lower mean serum prostate-specific antigen (non-metabolic syndrome group vs metabolic syndrome group; 1.22 ± 0.91 vs 1.15 ± 0.76 ng/mL, P = 0.006). Prostate-specific antigen mass density in the metabolic syndrome group was still significantly lower than that in the metabolic syndrome group (0.124 ± 0.084 vs 0.115 ± 0.071 μg/mL, P = 0.001). After adjusting for age, prostate volume and plasma volume using linear regression model, the presence of metabolic syndrome was a significant independent factor for lower prostate-specific antigen (prostate-specific antigen decrease by 4.1%, P = 0.046). Prostate-specific antigen levels in patients with metabolic syndrome seem to be lower, and this finding might be affected by the prostate volume. © 2016 The Japanese Urological Association.
Generality and specificity in cognitive aging: a volumetric brain analysis.
Staff, Roger T; Murray, Alison D; Deary, Ian J; Whalley, Lawrence J
2006-05-01
To investigate whether, in old age, brain volume differences are associated with age-related change in general mental ability and/or specific cognitive abilities. The authors investigate the association between brain volumes and current cognitive function in a well-characterized sample of healthy old people (aged 79-80) whose intelligence was recorded at age 11. This allowed estimation of intellectual change over the life span. After accounting for childhood intelligence, associations were found between specific cognitive measures and brain volumes. An association was also found between volumes and the general intelligence factor g. After removing the influence of g from each of the specific cognitive measures, no remaining significant associations were found between brain volumes and the specific part of each test. Generalized cognitive aging is associated with brain volume differences, but there is no evidence in this sample that specific components of cognitive aging are associated with differences in brain volume.
Diurnal Changes in Volume and Specific Tissue Weight of Crassulacean Acid Metabolism Plants 1
Chen, Sheng-Shu; Black, Clanton C.
1983-01-01
The diurnal variations in volume and in specific weight were determined for green stems and leaves of Crassulacen acid metabolism (CAM) plants. Volume changes were measured by a water displacement method. Diurnal variations occurred in the volume of green CAM tissues. Their volume increased early in the light period reaching a maximum about mid-day, then the volume decreased to a minimum near midnight. The maximum volume increase each day was about 2.7% of the total volume. Control leaves of C3 and C4 plants exhibited reverse diurnal volume changes of 0.2 to 0.4%. The hypothesis is presented and supported that green CAM tissues should exhibit a diurnal increase in volume due to the increase of internal gas pressure from CO2 and O2 when their stomata are closed. Conversely, the volume should decrease when the gas pressure is decreased. The second hypothesis presented and supported was that the specific weight (milligrams of dry weight per square centimeter of green surface area) of green CAM tissues should increase at night due to the net fixation of CO2. Green CAM tissues increased their specific weight at night in contrast to control C3 and C4 leaves which decreased their specific weight at night. With Kalanchoë daigremontiana leaves, the calculated increase in specific leaf weight at night based on estimates of carbohydrate available for net CO2 fixation was near 6% and the measured increase in specific leaf weight was 6%. Diurnal measurements of CAM tissue water content were neither coincident nor reciprocal with their diurnal patterns of either volume or specific weight changes. PMID:16662833
The Voronoi volume and molecular representation of molar volume: equilibrium simple fluids.
Hunjan, Jagtar Singh; Eu, Byung Chan
2010-04-07
The Voronoi volume of simple fluids was previously made use of in connection with volume transport phenomena in nonequilibrium simple fluids. To investigate volume transport phenomena, it is important to develop a method to compute the Voronoi volume of fluids in nonequilibrium. In this work, as a first step to this goal, we investigate the equilibrium limit of the nonequilibrium Voronoi volume together with its attendant related molar (molal) and specific volumes. It is proved that the equilibrium Voronoi volume is equivalent to the molar (molal) volume. The latter, in turn, is proved equivalent to the specific volume. This chain of equivalences provides an alternative procedure of computing the equilibrium Voronoi volume from the molar volume/specific volume. We also show approximate methods of computing the Voronoi and molar volumes from the information on the pair correlation function. These methods may be employed for their quick estimation, but also provide some aspects of the fluid structure and its relation to the Voronoi volume. The Voronoi volume obtained from computer simulations is fitted to a function of temperature and pressure in the region above the triple point but below the critical point. Since the fitting function is given in terms of reduced variables for the Lennard-Jones (LJ) model and the kindred volumes (i.e., specific and molar volumes) are in essence equivalent to the equation of state, the formula obtained is a reduced equation state for simple fluids obeying the LJ model potential in the range of temperature and pressure examined and hence can be used for other simple fluids.
NASA Astrophysics Data System (ADS)
Prameswari, I. K.; Manuhara, G. J.; Amanto, B. S.; Atmaka, W.
2018-05-01
Tapioca starch application in bread processing change water absorption level by the dough, while sufficient mixing time makes the optimal water absorption. This research aims to determine the effect of variations in water volume and mixing time on physical properties of tapioca starch – wheat composite bread and the best method for the composite bread processing. This research used Complete Randomized Factorial Design (CRFD) with two factors: variations of water volume (111,8 ml, 117,4 ml, 123 ml) and mixing time (16 minutes, 17 minutes 36 seconds, 19 minutes 12 seconds). The result showed that water volume significantly affected on dough volume, bread volume and specific volume, baking expansion, and crust thickness. Mixing time significantly affected on dough volume and specific volume, bread volume and specific volume, baking expansion, bread height, and crust thickness. While the combination of water volume and mixing time significantly affected for all physical properties parameters except crust thickness.
See, William A; Jacobson, Kenneth; Derus, Sue; Langenstroer, Peter
2014-11-01
Industry-sponsored websites for robotic surgery direct to surgeons listed as performing specific robotic surgical procedures. The purpose of this study was to compare average annual, surgeon-specific, case volumes for those procedures for which they were listed as performing on the commercial website with the volumes of all providers performing these same procedures across a defined geographic region. A list of providers within the state of Wisconsin cited as performing specific urologic procedures was obtained through the Intuitive Surgical website 〈http://www.davincisurgery.com/da-vinci-urology/〉. Surgeon-specific annual case volumes from 2009 to 2013 for these same cases were obtained for all Wisconsin providers through DataBay Resources (Warrendale, PA) based on International classification of diseases-9 codes. Procedural activity was rank ordered, and surgeons were placed in "volume deciles" derived from the total annual number of cases performed by all surgeons. The distribution of commercially listed surgeon volumes, both 5-year average and most recent year, was compared with the average and 2013 volumes of all surgeons performing a specific procedure. A total of 35 individual urologic surgeons listed as performing robotic surgery in Wisconsin were identified through a "search" using the Intuitive Surgical website. Specific procedure analysis returned 5, 12, 9, and 15 surgeon names for cystectomy, partial nephrectomy, radical nephrectomy, and prostatectomy, respectively. This compared with the total number of surgeons who had performed the listed procedure in Wisconsin at least 1 time during the prior 5 years of 123, 153, 242, and 165, respectively. When distributed by surgeon-volume deciles, surgeons listed on industry-sponsored sites varied widely in their respective volume decile. More than half of site-listed, procedure-specific surgeons fell below the fifth decile for surgeon volume. Data analysis based solely on 2013 case volumes had no effect on the number of website-listed surgeons whose volumes fell below the fifth decile. Surgeons listed on an industry-sponsored website demonstrate wide variation in the actual volume of specific procedures performed. The inferred endorsement of competence by commercial sites has the potential to mislead patients seeking surgical expertise. Providers should consider the ethical and legal implications of these commercial advertising that do not have volume or outcome data. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Srirejeki, S.; Manuhara, G. J.; Amanto, B. S.; Atmaka, W.; Laksono, P. W.
2018-03-01
Modification of cassava starch with soaking in the whey (by product on cheese production) resulted in changes of the flour characteristics. Adjustments of processing condition are important to be studied in the making of bread from modified cassava starch and wheat composite flour (30:70). This research aims to determine the effect of water volume and mixing time on the physical properties of the bread. The experimental design of this research was Completely Randomized Factorial Design (CRFD) with two factors which were water volume and mixing time. The variation of water volume significantly affected on bread height, dough volume, dough specific volume, and crust thickness. The variation of mixing time had a significant effect on the increase of dough volume and dough specific volume. The combination of water volume and mixing time had a significant effect on dough height, bread volume, bread specific volume, baking expansion, and weight loss.
The Moisture Content and Specific Gravity of the Bark and Wood of Northern Pulpwood Species
John R. Erickson
1972-01-01
Much information is available on the specific gravity of wood on a dry weight over green volume and dry weight over dry volume basis. This paper presents the conventional specific gravity on a green weight over green volume basis. The relative specific gravities of bark and wood chips may be helpful in finding way to remove bark particles from chips.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weber, E.R.
1983-09-01
This volume on specifications for the Saguaro Power Plant includes the following: subsystem interface definition document; solar collector subsystem specification; receiver specification; thermal energy storage specification; solar steam generator specification; and master control system specification.
Handbook of Parenting. Volume 3: Status and Social Conditions of Parenting.
ERIC Educational Resources Information Center
Bornstein, Marc H., Ed.
Highlighting the specific as well as common characteristics of different types of parents, this volume, the third of four volumes on parenting specifically deals with parental status and the social conditions of parenting. The volume consists of 17 chapters as follows: (1) "Mothering" (Kathryn E. Barnard and Louise K. Martell); (2)…
Code of Federal Regulations, 2012 CFR
2012-04-01
... respective volumes of alcohol and water and the specific gravity in both air and vacuum of spirituous liquor... volumes of alcohol and water and the specific gravity in both air and vacuum of spirituous liquor. This... gallon of water in air by the specific gravity in air of the spirits—8.32823 by 0.88862—the product (7...
Code of Federal Regulations, 2010 CFR
2010-04-01
... respective volumes of alcohol and water and the specific gravity in both air and vacuum of spirituous liquor... volumes of alcohol and water and the specific gravity in both air and vacuum of spirituous liquor. This... gallon of water in air by the specific gravity in air of the spirits—8.32823 by 0.88862—the product (7...
Code of Federal Regulations, 2011 CFR
2011-04-01
... respective volumes of alcohol and water and the specific gravity in both air and vacuum of spirituous liquor... volumes of alcohol and water and the specific gravity in both air and vacuum of spirituous liquor. This... gallon of water in air by the specific gravity in air of the spirits—8.32823 by 0.88862—the product (7...
Code of Federal Regulations, 2013 CFR
2013-04-01
... respective volumes of alcohol and water and the specific gravity in both air and vacuum of spirituous liquor... volumes of alcohol and water and the specific gravity in both air and vacuum of spirituous liquor. This... gallon of water in air by the specific gravity in air of the spirits—8.32823 by 0.88862—the product (7...
Code of Federal Regulations, 2014 CFR
2014-04-01
... respective volumes of alcohol and water and the specific gravity in both air and vacuum of spirituous liquor... volumes of alcohol and water and the specific gravity in both air and vacuum of spirituous liquor. This... gallon of water in air by the specific gravity in air of the spirits—8.32823 by 0.88862—the product (7...
Handbook of Parenting. Volume 3: Being and Becoming a Parent. Second Edition.
ERIC Educational Resources Information Center
Bornstein, Marc H., Ed.
Highlighting the specific as well as common characteristics of different types of parents, this volume, the third of five volumes on parenting, deals specifically with parental status and the social conditions of parenting. The volume consists of 20 chapters as follows: (1) "Mothering" (Kathryn E. Barnard and JoAnne E. Solchany); (2)…
Hippocampal and Parahippocampal Volumes in Schizophrenia: A Structural MRI Study
Sim, Kang; DeWitt, Iain; Ditman, Tali; Zalesak, Martin; Greenhouse, Ian; Goff, Donald; Weiss, Anthony P; Heckers, Stephan
2006-01-01
Smaller medial temporal lobe volume is a frequent finding in studies of patients with schizophrenia, but the relative contributions of the hippocampus and three surrounding cortical regions (entorhinal cortex, perirhinal cortex, and parahippocampal cortex) are poorly understood. We tested the hypothesis that the volumes of medial temporal lobe regions are selectively changed in schizophrenia. We studied 19 male patients with schizophrenia and 19 age-matched male control subjects. Hippocampal and cortical volumes were estimated using a three-dimensional morphometric protocol for the analysis of high-resolution structural magnetic resonance images, and repeated measures ANOVA was used to test for region-specific differences. Patients had smaller overall medial temporal lobe volumes compared to controls. The volume difference was not specific for either region or hemisphere. The finding of smaller medial temporal lobe volumes in the absence of regional specificity has important implications for studying the functional role of the hippocampus and surrounding cortical regions in schizophrenia. PMID:16319377
Tract-Specific Volume Loss on 3T MRI in Patients with Cervical Spondylotic Myelopathy.
Hopkins, Benjamin S; Weber, Kenneth A; Cloney, Michael Brendan; Paliwal, Monica; Parrish, Todd B; Smith, Zachary A
2018-04-11
Case-control. The aim of this study was to understand the role of high-resolution magnetic resonance (MR) in identifying regional cord volume loss in cervical spondylotic myelopathy (CSM). Preliminary studies suggest that compression of the ventral region of the cord may contribute disproportionately to CSM symptomology; however, tract-specific data are lacking in the CSM population. The current study is the first to use 3T MR imaging (MRI) images of CSM patients to determine specific volume loss at the level of detail of individual descending white matter tracts. Twelve patients with CSM and 14 age-matched were enrolled prospectively and underwent 3-Tesla MRI of the cervical spine. Using the high-resolution images of the spinal cord, straightening and alignment with a template was performed and specific spinal cord tract volumes were measured using Spinal Cord Tool-box version 3.0.7. Modified Japanese orthopedic association (mJOA) and Nurick disability scores were collected in a prospective manner and were analyzed in relation to descending spinal tract volumes. Having CSM was predicted by anterior/posterior diameter, eccentricity of the cord [odds ratio (OR) 0.000000621, P = 0.004], ventral reticulospinal tract volume (OR 1.167, P = 0.063), lateral corticospinal tract volume (OR 1.034, P = 0.046), rubrospinal tract volume (OR 1.072, P = 0.011), and ventrolateral reticulospinal tract volume (OR 1.474, P = 0.005) on single variable logistic regression. Single variable linear regression showed decreases in anterior/posterior spinal cord diameter (P = 0.022), ventral reticulospinal tract volumes (P = 0.007), and ventrolateral reticulospinal tract volumes (P = 0.017) to significantly predict worsening mJOA scores. Similarly, decreases in ventral reticulospinal tract volumes significantly predicted increasing Nurick scores (P = 0.039). High-resolution 3T MRI can detect tract-specific volume loss in descending spinal cord tracts in CSM patients. Anterior/posterior spinal cord diameter, ventral reticulospinal tract, ventrolateral reticulospinal tract, lateral corticospinal tract, and rubrospinal tract volume loss are associated with CSM symptoms. 2.
NASA Technical Reports Server (NTRS)
Callender, E. David; Steinbacher, Jody
1989-01-01
This is the fourth of five volumes on Information System Life-Cycle and Documentation Standards. This volume provides a well organized, easily used standard for assurance documentation for information systems and software, hardware, and operational procedures components, and related processes. The specifications are developed in conjunction with the corresponding management plans specifying the assurance activities to be performed.
Mod-5A wind turbine generator program design report. Volume 4: Drawings and specifications, book 5
NASA Technical Reports Server (NTRS)
1984-01-01
The design, development and analysis of the 7.3 MW MOD-5A wind turbine generator is documented. There are four volumes. This volume contains the drawings and specifications that were developed in preparation for building the MOD-5A wind turbine generator. Detail drawings of several assemblies and subassemblies are given. This is the fifth book of volume 4.
Kanter, Michael H; Huang, Yii-Chieh; Kally, Zina; Gordon, Margo A; Meltzer, Charles
2018-06-01
A well-documented association exists between higher surgeon volumes and better outcomes for many procedures, but surgeons may be reluctant to change practice patterns without objective, credible, and near real-time data on their performance. In addition, published thresholds for procedure volumes may be biased or perceived as arbitrary; typical reports compare surgeons grouped into discrete procedure volume categories, even though the volume-outcomes relationship is likely continuous. The concentration curves methodology, which has been used to analyze whether health outcomes vary with socioeconomic status, was adapted to explore the association between procedure volume and outcomes as a continuous relationship so that data for all surgeons within a health care organization could be included. Using widely available software and requiring minimal analytic expertise, this approach plots cumulative percentages of two variables of interest against each other and assesses the characteristics of the resulting curve. Organization-specific relationships between surgeon volumes and outcomes were examined for three example types of procedures: uncomplicated hysterectomies, infant circumcisions, and total thyroidectomies. The concentration index was used to assess whether outcomes were equally distributed unrelated to volumes. For all three procedures, the concentration curve methodology identified associations between surgeon procedure volumes and selected outcomes that were specific to the organization. The concentration indices confirmed the higher prevalence of examined outcomes among low-volume surgeons. The curves supported organizational discussions about surgical quality. Concentration curves require minimal resources to identify organization- and procedure-specific relationships between surgeon procedure volumes and outcomes and can support quality improvement. Copyright © 2018 The Joint Commission. Published by Elsevier Inc. All rights reserved.
The Surgeon Volume-outcome Relationship: Not Yet Ready for Policy.
Modrall, J Gregory; Minter, Rebecca M; Minhajuddin, Abu; Eslava-Schmalbach, Javier; Joshi, Girish P; Patel, Shivani; Rosero, Eric B
2018-05-01
Increasing surgeon volume may improve outcomes for index operations. We hypothesized that there may be surrogate operative experiences that yield similar outcomes for surgeons with a low-volume experience with a specific index operation, such as esophagectomy. The relationship between surgeon volume and outcomes has potential implications for credentialing of surgeons. Restrictions of privileges based on surgeon volume are only reasonable if there is no substitute for direct experience with the index operation. This study was aimed at determining whether there are valid surrogates for direct experience with a sample index operation-open esophagectomy. The Nationwide Inpatient Sample (2003-2009) was utilized. Surgeons were stratified into low and high-volume groups based on annual volume of esophagectomy. Surrogate volume was defined as the aggregate annual volume per surgeon of upper gastrointestinal operations including excision of esophageal diverticulum, gastrectomy, gastroduodenectomy, and repair of diaphragmatic hernia. In all, 26,795 esophagectomies were performed nationwide (2003-2009), with a crude inhospital mortality rate of 5.2%. Inhospital mortality decreased with increasing volume of esophagectomies performed annually: 7.7% and 3.8% for low and high-volume surgeons, respectively (P < 0.0001). Among surgeons with a low-volume esophagectomy experience, increasing volume of surrogate operations improved the outcomes observed for esophagectomy: 9.7%, 7.1%, and 4.3% for low, medium, and high-surrogate-volume surgeons, respectively (P = 0.016). Both operation-specific volume and surrogate volume are significant predictors of inhospital mortality for esophagectomy. Based on these observations, it would be premature to limit hospital privileges based solely on operation-specific surgeon volume criteria.
A Comparison of Regional and SiteSpecific Volume Estimation Equations
Joe P. McClure; Jana Anderson; Hans T. Schreuder
1987-01-01
Regression equations for volume by region and site class were examined for lobiolly pine. The regressions for the Coastal Plain and Piedmont regions had significantly different slopes. The results shared important practical differences in percentage of confidence intervals containing the true total volume and in percentage of estimates within a specific proportion of...
Cognitive correlates of white matter lesion load and brain atrophy
Dong, Chuanhui; Nabizadeh, Nooshin; Caunca, Michelle; Cheung, Ying Kuen; Rundek, Tatjana; Elkind, Mitchell S.V.; DeCarli, Charles; Sacco, Ralph L.; Stern, Yaakov
2015-01-01
Objective: We investigated white matter lesion load and global and regional brain volumes in relation to domain-specific cognitive performance in the stroke-free Northern Manhattan Study (NOMAS) population. Methods: We quantified white matter hyperintensity volume (WMHV), total cerebral volume (TCV), and total lateral ventricular (TLV) volume, as well as hippocampal and cortical gray matter (GM) lobar volumes in a subgroup. We used general linear models to examine MRI markers in relation to domain-specific cognitive performance, adjusting for key covariates. Results: MRI and cognitive data were available for 1,163 participants (mean age 70 ± 9 years; 60% women; 66% Hispanic, 17% black, 15% white). Across the entire sample, those with greater WMHV had worse processing speed. Those with larger TLV volume did worse on episodic memory, processing speed, and semantic memory tasks, and TCV did not explain domain-specific variability in cognitive performance independent of other measures. Age was an effect modifier, and stratified analysis showed that TCV and WMHV explained variability in some domains above age 70. Smaller hippocampal volume was associated with worse performance across domains, even after adjusting for APOE ε4 and vascular risk factors, whereas smaller frontal lobe volumes were only associated with worse executive function. Conclusions: In this racially/ethnically diverse, community-based sample, white matter lesion load was inversely associated with cognitive performance, independent of brain atrophy. Lateral ventricular, hippocampal, and lobar GM volumes explained domain-specific variability in cognitive performance. PMID:26156514
Lewis, Jane Ea; Williams, Paul; Davies, Jane H
2016-01-01
This cross-sectional study aimed to individually and cumulatively compare sensitivity and specificity of the (1) ankle brachial index and (2) pulse volume waveform analysis recorded by the same automated device, with the presence or absence of peripheral arterial disease being verified by ultrasound duplex scan. Patients (n=205) referred for lower limb arterial assessment underwent ankle brachial index measurement and pulse volume waveform recording using volume plethysmography, followed by ultrasound duplex scan. The presence of peripheral arterial disease was recorded if ankle brachial index <0.9; pulse volume waveform was graded as 2, 3 or 4; or if haemodynamically significant stenosis >50% was evident with ultrasound duplex scan. Outcome measure was agreement between the measured ankle brachial index and interpretation of pulse volume waveform for peripheral arterial disease diagnosis, using ultrasound duplex scan as the reference standard. Sensitivity of ankle brachial index was 79%, specificity 91% and overall accuracy 88%. Pulse volume waveform sensitivity was 97%, specificity 81% and overall accuracy 85%. The combined sensitivity of ankle brachial index and pulse volume waveform was 100%, specificity 76% and overall accuracy 85%. Combining these two diagnostic modalities within one device provided a highly accurate method of ruling out peripheral arterial disease, which could be utilised in primary care to safely reduce unnecessary secondary care referrals.
Estimating Highway Volumes Using Vehicle Probe Data - Proof of Concept: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hou, Yi; Young, Stanley E; Sadabadi, Kaveh
This paper examines the feasibility of using sampled commercial probe data in combination with validated continuous counter data to accurately estimate vehicle volume across the entire roadway network, for any hour during the year. Currently either real time or archived volume data for roadways at specific times are extremely sparse. Most volume data are average annual daily traffic (AADT) measures derived from the Highway Performance Monitoring System (HPMS). Although methods to factor the AADT to hourly averages for typical day of week exist, actual volume data is limited to a sparse collection of locations in which volumes are continuously recorded.more » This paper explores the use of commercial probe data to generate accurate volume measures that span the highway network providing ubiquitous coverage in space, and specific point-in-time measures for a specific date and time. The paper examines the need for the data, fundamental accuracy limitations based on a basic statistical model that take into account the sampling nature of probe data, and early results from a proof of concept exercise revealing the potential of probe type data calibrated with public continuous count data to meet end user expectations in terms of accuracy of volume estimates.« less
DETERMINATION OF THE SPEED OF SOUND ALONG THE HUGONIOT IN A SHOCKED MATERIAL
2017-04-25
correctly predict higher speeds of sound for the higher energy shocked states. The approximations of higher shock pressures diverge progressively...List 11 FIGURES 1 Copper Hugoniot pressure-specific volume plane 4 2 Copper Hugoniot energy -specific volume plane 4 3 Comparison between rate of...volume and energy are being used. = (, ) Then by the chain rule: = | + | Dividing by dv
Halpern, Joshua A; Shoag, Jonathan E; Artis, Amanda S; Ballman, Karla V; Sedrakyan, Art; Hershman, Dawn L; Wright, Jason D; Shih, Ya Chen Tina; Hu, Jim C
2017-02-01
Studies demonstrate that use of prostate-specific antigen screening decreased significantly following the US Preventive Services Task Force (USPSTF) recommendation against prostate-specific antigen screening in 2012. To determine downstream effects on practice patterns in prostate cancer diagnosis and treatment following the 2012 USPSTF recommendation. Procedural volumes of certifying and recertifying urologists from 2009 through 2016 were evaluated for variation in prostate biopsy and radical prostatectomy (RP) volume. Trends were confirmed using the New York Statewide Planning and Research Cooperative System and Nationwide Inpatient Sample. The study included a representative sample of urologists across practice settings and nationally representative sample of all RP discharges. We obtained operative case logs from the American Board of Urology and identified urologists performing at least 1 prostate biopsy (n = 5173) or RP (n = 3748), respectively. The 2012 USPSTF recommendation against routine population-wide prostate-specific antigen screening. Change in median biopsy and RP volume per urologist and national procedural volume. Following the USPSTF recommendation, median biopsy volume per urologist decreased from 29 to 21 (interquartile range [IQR}, 12-34; P < .001). After adjusting for physician and practice characteristics, biopsy volume decreased by 28.7% following 2012 (parameter estimate, -0.25; SE, 0.03; P < .001). Similarly, following the USPSTF recommendation, median RP volume per urologist decreased from 7 (IQR, 3-15) to 6 (IQR, 2-12) (P < .001), and in adjusted analyses, RP volume decreased 16.2% (parameter estimate, -0.15; SE, 0.05; P = .003). Following the 2012 USPSTF recommendation, prostate biopsy and RP volumes decreased significantly. A panoramic vantage point is needed to evaluate the long-term consequences of the 2012 USPSTF recommendation.
ERIC Educational Resources Information Center
Schalock, H. Del, Ed.; Hale, James R., Ed.
This main volume (SP 002 155-SP 002 180 comprise the appendixes to this volume) explains the ComField (competency based, field centered) Model--a systems approach to the education of elementary school teachers which entails specifications (1) for instruction and (2) for management of the instructional program. In an overview, the ComField Model is…
Spacecraft Habitable Volume: Results of an Interdisciplinary Workshop
NASA Technical Reports Server (NTRS)
Fitts, David J.; Connolly, Janis; Howard, Robert
2011-01-01
NASA's Human Exploration Framework Team posed the question: "Is 80 cubic meters per person of habitable volume acceptable for a proposed Deep Space Habitat?" The goal of the workshop was to address the "net habitable volume" necessary for long-duration human spaceflight missions and identify design and psychological issues and mitigations. The objectives were: (1) Identify psychological factors -- i.e., "stressors" -- that impact volume and layout specifications for long duration missions (2) Identify mitigation strategies for stressors, especially those that can be written as volume design specifications (3) Identify a forward research roadmap -- i.e., what future work is needed to define and validate objective design metrics? (4) Provide advisories on the human factors consequences of poor net habitable volume allocation and layout design.
Mazzini, Virginia; Craig, Vincent S J
2017-10-01
The importance of electrolyte solutions cannot be overstated. Beyond the ionic strength of electrolyte solutions the specific nature of the ions present is vital in controlling a host of properties. Therefore ion specificity is fundamentally important in physical chemistry, engineering and biology. The observation that the strengths of the effect of ions often follows well established series suggests that a single predictive and quantitative description of specific-ion effects covering a wide range of systems is possible. Such a theory would revolutionise applications of physical chemistry from polymer precipitation to drug design. Current approaches to understanding specific-ion effects involve consideration of the ions themselves, the solvent and relevant interfaces and the interactions between them. Here we investigate the specific-ion effects trends of standard partial molar volumes and electrostrictive volumes of electrolytes in water and eleven non-aqueous solvents. We choose these measures as they relate to bulk properties at infinite dilution, therefore they are the simplest electrolyte systems. This is done to test the hypothesis that the ions alone exhibit a specific-ion effect series that is independent of the solvent and unrelated to surface properties. The specific-ion effects trends of standard partial molar volumes and normalised electrostrictive volumes examined in this work show a fundamental ion-specific series that is reproduced across the solvents, which is the Hofmeister series for anions and the reverse lyotropic series for cations, supporting the hypothesis. This outcome is important in demonstrating that ion specificity is observed at infinite dilution and demonstrates that the complexity observed in the manifestation of specific-ion effects in a very wide range of systems is due to perturbations of solvent, surfaces and concentration on the underlying fundamental series. This knowledge will guide a general understanding of specific-ion effects and assist in the development of a quantitative predictive theory of ion specificity.
Depping, Malte S; Wolf, Nadine D; Vasic, Nenad; Sambataro, Fabio; Thomann, Philipp A; Christian Wolf, R
2015-03-15
Abnormal brain volume has been frequently demonstrated in major depressive disorder (MDD). It is unclear if these findings are specific for MDD since aberrant brain structure is also present in disorders with depressive comorbidity and affective dysregulation, such as borderline personality disorder (BPD). In this transdiagnostic study, we aimed to investigate if regional brain volume loss differentiates between MDD and BPD. Further, we tested for associations between brain volume and clinical variables within and between diagnostic groups. 22 Females with a DSM-IV diagnosis of MDD, 17 females with a DSM-IV diagnosis of BPD and without comorbid posttraumatic stress disorder, and 22 age-matched female healthy controls (HC) were investigated using magnetic resonance imaging. High-resolution structural data were analyzed using voxel-based morphometry. A significant (p<0.05, cluster-corrected) volume decrease of the anterior cingulate cortex (ACC) was found in MDD compared to HC, as opposed to volume decreases of the amygdala in BPD compared to both HC and MDD. Sensitivity and specificity of regional gray matter volume for a diagnosis of MDD were modest to fair. Amygdala volume was related to depressive symptoms across the entire patient sample. Potential limitations of this study include the modest sample size and the heterogeneous psychotropic drug treatment. ACC volume reduction is more pronounced in MDD with an intermediate degree of volume loss in BPD compared to HC. In contrast, amygdala volume loss is more pronounced in BPD compared to MDD, yet amygdala volume is associated with affective symptom expression in both disorders. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Callender, E. David; Steinbacher, Jody
1989-01-01
This is the third of five volumes on Information System Life-Cycle and Documentation Standards which present a well organized, easily used standard for providing technical information needed for developing information systems, components, and related processes. This volume states the Software Management and Assurance Program documentation standard for a product specification document and for data item descriptions. The framework can be applied to any NASA information system, software, hardware, operational procedures components, and related processes.
Students' Reasoning about Invariance of Volume as a Quantity
ERIC Educational Resources Information Center
Kara, Melike
2013-01-01
The aims of this study were to investigate how upper-elementary-grade students compare the volume of rectangular prisms of equal volume (specifically, students' noticing and reasoning for invariance of volume and coordination of the three linear dimensions of rectangular prisms) and how students' levels of sophistication in volume measurement…
Evaluation of the LWVD Luminosity for Use in the Spectral-Based Volume Sensor Algorithms
2010-04-29
VMI Vibro-Meter, Inc. VS Volume Sensor VSCS Volume Sensor Communications Specification VSDS Volume Sensor Detection Suite VSNP Volume Sensor Nodal Panel...using the VSCS communications protocol. Appendix A gives a complete listing of the SBVS EVENT parameters and the EVENT algorithm descriptions. See
SOLID WASTE INTEGRATED FORECAST TECHNICAL (SWIFT) REPORT FY2005 THRU FY2035 VERSION 2005.0 VOLUME 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
BARCOT, R.A.
2005-04-13
The SWIFT Report provides up-to-date life cycle information about the radioactive solid waste expected to be managed by Hanford's Waste Management (WM) Project from onsite and offsite generators. This report is an annual update to the SWIFT 2004.1 report that was published in August 2004. The SWIFT Report is published in two volumes. SWIFT Volume II provides detailed analyses of the data, graphical representation, comparison to previous years, and waste generator specific information. The data contained in this report are the official data for solid waste forecasting. In this revision, the volume numbers have been switched to reflect the timingmore » of their release. This particular volume provides the following data reports: (1) Summary volume data by DOE Office, company, and location; (2) Annual volume data by waste generator; (3) Annual waste specification record and physical waste form volume; (4) Radionuclide activities and dose-equivalent curies; and (5) Annual container type data by volume and count.« less
NASA Astrophysics Data System (ADS)
Sobina, E.; Zimathis, A.; Prinz, C.; Emmerling, F.; Unger, W.; de Santis Neves, R.; Galhardo, C. E.; De Robertis, E.; Wang, H.; Mizuno, K.; Kurokawa, A.
2016-01-01
CCQM key comparison K-136 Measurement of porosity properties (specific adsorption, BET specific surface area, specific pore volume and pore diameter) of nanoporous Al2O3 has been performed by the Surface Analysis Working Group (SAWG) of the Consultative Committee for Amount of Substance (CCQM). The objective of this key comparison is to compare the equivalency of the National Metrology Institutes (NMIs) and Designated Institutes (DIs) for the measurement of specific adsorption, BET specific surface area, specific pore volume and pore diameter) of nanoporous substances (sorbents, catalytic agents, cross-linkers, zeolites, etc) used in advanced technology. In this key comparison, a commercial sorbent (aluminum oxide) was supplied as a sample. Five NMIs participated in this key comparison. All participants used a gas adsorption method, here nitrogen adsorption at 77.3 K, for analysis according to the international standards ISO 15901-2 and 9277. In this key comparison, the degrees of equivalence uncertainties for specific adsorption, BET specific surface area, specific pore volume and pore diameter was established. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Technical Reports Server (NTRS)
Mckee, James W.
1990-01-01
This volume (3 of 4) contains the specification for the command language for the AMPS system. The volume contains a requirements specification for the operating system and commands and a design specification for the operating system and command. The operating system and commands sits on top of the protocol. The commands are an extension of the present set of AMPS commands in that the commands are more compact, allow multiple sub-commands to be bundled into one command, and have provisions for identifying the sender and the intended receiver. The commands make no change to the actual software that implement the commands.
NASA Technical Reports Server (NTRS)
1995-01-01
The Formal Methods Specification and Verification Guidebook for Software and Computer Systems describes a set of techniques called Formal Methods (FM), and outlines their use in the specification and verification of computer systems and software. Development of increasingly complex systems has created a need for improved specification and verification techniques. NASA's Safety and Mission Quality Office has supported the investigation of techniques such as FM, which are now an accepted method for enhancing the quality of aerospace applications. The guidebook provides information for managers and practitioners who are interested in integrating FM into an existing systems development process. Information includes technical and administrative considerations that must be addressed when establishing the use of FM on a specific project. The guidebook is intended to aid decision makers in the successful application of FM to the development of high-quality systems at reasonable cost. This is the first volume of a planned two-volume set. The current volume focuses on administrative and planning considerations for the successful application of FM.
DOT National Transportation Integrated Search
1993-03-01
This report is the fourth of four volumes concerned with developing safety guidelines and specifications for high-speed : guided ground transportation (HSGGT) collision avoidance and accident survivability. The overall approach taken in this : study ...
Mod-5A wind turbine generator program design report. Volume 4: Drawings and specifications, book 3
NASA Technical Reports Server (NTRS)
1984-01-01
The design, development and analysis of the 7.3 MW MOD-5A wind turbine generator is documented. This volume contains the drawings and specifications developed for the final design. This volume is divided into 5 books of which this is the third, containing drawings 47A380074 through 47A380126. A full breakdown parts listing is provided as well as a where used list.
Quantitative genetics and sex-specific selection on sexually dimorphic traits in bighorn sheep
Poissant, Jocelyn; Wilson, Alastair J; Festa-Bianchet, Marco; Hogg, John T; Coltman, David W
2008-01-01
Sexual conflict at loci influencing traits shared between the sexes occurs when sex-specific selection pressures are antagonistic relative to the genetic correlation between the sexes. To assess whether there is sexual conflict over shared traits, we estimated heritability and intersexual genetic correlations for highly sexually dimorphic traits (horn volume and body mass) in a wild population of bighorn sheep (Ovis canadensis) and quantified sex-specific selection using estimates of longevity and lifetime reproductive success. Body mass and horn volume showed significant additive genetic variance in both sexes, and intersexual genetic correlations were 0.24±0.28 for horn volume and 0.63±0.30 for body mass. For horn volume, selection coefficients did not significantly differ from zero in either sex. For body weight, selection coefficients were positive in females but did not differ from zero in males. The absence of detectable sexually antagonistic selection suggests that currently there are no sexual conflicts at loci influencing horn volume and body mass. PMID:18211870
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This volume, the second of two such volumes, contains sector-specific guidance in support of the General Guidelines for the voluntary reporting of greenhouse gas emissions and carbon sequestration. This voluntary reporting program was authorized by Congress in Section 1605(b) of the Energy Policy Act of 1992. The General Guidelines, bound separately from this volume, provide the overall rationale for the program, discuss in general how to analyze emissions and emission reduction/carbon sequestration projects, and address programmatic issues such as minimum reporting requirements, time parameters, international projects, confidentiality, and certification. Together, the General Guidelines and the guidance in these supporting documentsmore » will provide concepts and approaches needed to prepare the reporting forms. This second volume of sector-specific guidance covers the transportation sector, the forestry sector, and the agricultural sector.« less
Aydogdu, Ayca; Sumnu, Gulum; Sahin, Serpil
2018-02-01
The aim of this study was to investigate the effects of addition of dietary fibers on rheological properties of batter and cake quality. Wheat flour was replaced by 5 and 10% (wt%) oat, pea, apple and lemon fibers. All cake batters showed shear thinning behavior. Incorporation of fibers increased consistency index (k), storage modulus (G') and loss modulus (G″). As quality parameters, specific volume, hardness, weight loss, color and microstructure of cakes were investigated. Cakes containing oat and pea fibers (5%) had similar specific volume and texture with control cakes which contained no fiber. As fiber concentration increased, specific volume decreased but hardness increased. No significant difference was found between weight loss of control cake and cakes with oat, pea and apple fibers. Lemon fiber enriched cakes had the lowest specific volume, weight loss and color difference. When microstructural images were examined, it was seen that control cake had more porous structure than fiber enriched cakes. In addition, lemon and apple fiber containing cakes had less porous crumb structure as compared to oat and pea containing ones. Oat and pea fiber (5%) enriched cakes had similar physical properties (volume, texture and color) with control cakes.
DOT National Transportation Integrated Search
1993-03-01
This report is the fourth of four volumes concerned with developing safety guidelines and specifications for high-speed guided ground transportation (HSGGT) collision avoidance and accident survivability. The overall approach taken in this study is t...
DOT National Transportation Integrated Search
1973-02-01
The volume provides a functional description and specification for the Satellite-Based Advanced Air Traffic Management System. The system description is presented in terms of the surveillance, navigation, and communications functions along with the a...
Density contrast sedimentation velocity for the determination of protein partial-specific volumes.
Brown, Patrick H; Balbo, Andrea; Zhao, Huaying; Ebel, Christine; Schuck, Peter
2011-01-01
The partial-specific volume of proteins is an important thermodynamic parameter required for the interpretation of data in several biophysical disciplines. Building on recent advances in the use of density variation sedimentation velocity analytical ultracentrifugation for the determination of macromolecular partial-specific volumes, we have explored a direct global modeling approach describing the sedimentation boundaries in different solvents with a joint differential sedimentation coefficient distribution. This takes full advantage of the influence of different macromolecular buoyancy on both the spread and the velocity of the sedimentation boundary. It should lend itself well to the study of interacting macromolecules and/or heterogeneous samples in microgram quantities. Model applications to three protein samples studied in either H(2)O, or isotopically enriched H(2) (18)O mixtures, indicate that partial-specific volumes can be determined with a statistical precision of better than 0.5%, provided signal/noise ratios of 50-100 can be achieved in the measurement of the macromolecular sedimentation velocity profiles. The approach is implemented in the global modeling software SEDPHAT.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1979-10-01
Volume IV of the ISTUM documentation gives information on the individual technology specifications, but relates closely with Chapter II of Volume I. The emphasis in that chapter is on providing an overview of where each technology fits into the general-model logic. Volume IV presents the actual cost structure and specification of every technology modeled in ISTUM. The first chapter presents a general overview of the ISTUM technology data base. It includes an explanation of the data base printouts and how the separate-cost building blocks are combined to derive an aggregate-technology cost. The remaining chapters are devoted to documenting the specific-technologymore » cost specifications. Technologies included are: conventional technologies (boiler and non-boiler conventional technologies); fossil-energy technologies (atmospheric fluidized bed combustion, low Btu coal and medium Btu coal gasification); cogeneration (steam, machine drive, and electrolytic service sectors); and solar and geothermal technologies (solar steam, solar space heat, and geothermal steam technologies), and conservation technologies.« less
Ozkahraman, Betul Canan; Sumnu, Gulum; Sahin, Serpil
2016-03-01
The objective of this study was to compare the quality of legume cakes baked in microwave-infrared combination (MW-IR) oven with conventional oven. Legume cake formulations were developed by replacing 10 % wheat flour by lentil, chickpea and pea flour. As a control, wheat flour containing cakes were used. Weight loss, specific volume, texture, color, gelatinization degree, macro and micro-structure of cakes were investigated. MW-IR baked cakes had higher specific volume, weight loss and crust color change and lower hardness values than conventionally baked cakes. Larger pores were observed in MW-IR baked cakes according to scanning electron microscope (SEM) images. Pea flour giving the hardest structure, lowest specific volume and gelatinization degree was determined to be the least acceptable legume flour. On the other hand, lentil and chickpea flour containing cakes had the softest structure and highest specific volume showing that lentil and chickpea flour can be used to produce functional cakes.
STORMWATER BEST MANAGEMENT PRACTICES DESIGN GUIDE VOLUME 2 - VEGETATIVE BIOFILTERS
This document is Volume 2 of a three volume document that provides guidance on the selection and design of stormwater management Best Management Practices (BMPs). This second volume provides specific design guidance for a group of onsite BMP control practices that are referred t...
Mazzini, Virginia
2017-01-01
The importance of electrolyte solutions cannot be overstated. Beyond the ionic strength of electrolyte solutions the specific nature of the ions present is vital in controlling a host of properties. Therefore ion specificity is fundamentally important in physical chemistry, engineering and biology. The observation that the strengths of the effect of ions often follows well established series suggests that a single predictive and quantitative description of specific-ion effects covering a wide range of systems is possible. Such a theory would revolutionise applications of physical chemistry from polymer precipitation to drug design. Current approaches to understanding specific-ion effects involve consideration of the ions themselves, the solvent and relevant interfaces and the interactions between them. Here we investigate the specific-ion effects trends of standard partial molar volumes and electrostrictive volumes of electrolytes in water and eleven non-aqueous solvents. We choose these measures as they relate to bulk properties at infinite dilution, therefore they are the simplest electrolyte systems. This is done to test the hypothesis that the ions alone exhibit a specific-ion effect series that is independent of the solvent and unrelated to surface properties. The specific-ion effects trends of standard partial molar volumes and normalised electrostrictive volumes examined in this work show a fundamental ion-specific series that is reproduced across the solvents, which is the Hofmeister series for anions and the reverse lyotropic series for cations, supporting the hypothesis. This outcome is important in demonstrating that ion specificity is observed at infinite dilution and demonstrates that the complexity observed in the manifestation of specific-ion effects in a very wide range of systems is due to perturbations of solvent, surfaces and concentration on the underlying fundamental series. This knowledge will guide a general understanding of specific-ion effects and assist in the development of a quantitative predictive theory of ion specificity. PMID:29147533
You save money when you buy in bulk: does volume-based pricing cause people to buy more beer?
Bray, Jeremy W; Loomis, Brett R; Engelen, Mark
2009-05-01
This paper uses supermarket scanner data to estimate brand- and packaging-specific own- and cross-price elasticities for beer. We find that brand- and packaging-specific beer sales are highly price elastic. Cross-price elasticity estimates suggest that individuals are more likely to buy a higher-volume package of the same brand of beer than they are to switch brands. Policy simulations suggest that regulation of volume-based price discounts is potentially more effective than a tax increase at reducing beer consumption. Our results suggest that volume-based price discounting induces people to buy larger-volume packages of beer and may lead to an increased overall beer consumption. (c) 2008 John Wiley & Sons, Ltd.
Zhu, F; Kuhlmann, M K; Kaysen, G A; Sarkar, S; Kaitwatcharachai, C; Khilnani, R; Stevens, L; Leonard, E F; Wang, J; Heymsfield, S; Levin, N W
2006-02-01
Discrepancies in body fluid estimates between segmental bioimpedance spectroscopy (SBIS) and gold-standard methods may be due to the use of a uniform value of tissue resistivity to compute extracellular fluid volume (ECV) and intracellular fluid volume (ICV). Discrepancies may also arise from the exclusion of fluid volumes of hands, feet, neck, and head from measurements due to electrode positions. The aim of this study was to define the specific resistivity of various body segments and to use those values for computation of ECV and ICV along with a correction for unmeasured fluid volumes. Twenty-nine maintenance hemodialysis patients (16 men) underwent body composition analysis including whole body MRI, whole body potassium (40K) content, deuterium, and sodium bromide dilution, and segmental and wrist-to-ankle bioimpedance spectroscopy, all performed on the same day before a hemodialysis. Segment-specific resistivity was determined from segmental fat-free mass (FFM; by MRI), hydration status of FFM (by deuterium and sodium bromide), tissue resistance (by SBIS), and segment length. Segmental FFM was higher and extracellular hydration of FFM was lower in men compared with women. Segment-specific resistivity values for arm, trunk, and leg all differed from the uniform resistivity used in traditional SBIS algorithms. Estimates for whole body ECV, ICV, and total body water from SBIS using segmental instead of uniform resistivity values and after adjustment for unmeasured fluid volumes of the body did not differ significantly from gold-standard measures. The uniform tissue resistivity values used in traditional SBIS algorithms result in underestimation of ECV, ICV, and total body water. Use of segmental resistivity values combined with adjustment for body volumes that are neglected by traditional SBIS technique significantly improves estimations of body fluid volume in hemodialysis patients.
Al JABBARI, Youssef S.; TSAKIRIDIS, Peter; ELIADES, George; AL-HADLAQ, Solaiman M.; ZINELIS, Spiros
2012-01-01
Objective The aim of this study was to quantify the surface area, volume and specific surface area of endodontic files employing quantitative X-ray micro computed tomography (mXCT). Material and Methods Three sets (six files each) of the Flex-Master Ni-Ti system (Nº 20, 25 and 30, taper .04) were utilized in this study. The files were scanned by mXCT. The surface area and volume of all files were determined from the cutting tip up to 16 mm. The data from the surface area, volume and specific area were statistically evaluated using the one-way ANOVA and SNK multiple comparison tests at α=0.05, employing the file size as a discriminating variable. The correlation between the surface area and volume with nominal ISO sizes were tested employing linear regression analysis. Results The surface area and volume of Nº 30 files showed the highest value followed by Nº 25 and Nº 20 and the differences were statistically significant. The Nº 20 files showed a significantly higher specific surface area compared to Nº 25 and Nº 30. The increase in surface and volume towards higher file sizes follows a linear relationship with the nominal ISO sizes (r2=0.930 for surface area and r2=0.974 for volume respectively). Results indicated that the surface area and volume demonstrated an almost linear increase while the specific surface area exhibited an abrupt decrease towards higher sizes. Conclusions This study demonstrates that mXCT can be effectively applied to discriminate very small differences in the geometrical features of endodontic micro-instruments, while providing quantitative information for their geometrical properties. PMID:23329248
1977-04-01
U* AFFDL-TR-77-7 0 VOLUME III " VALIDATION OF MIL-F-9490D - GENERAL SPECIFICATION FOR FLIGHT CONTROL SYSTEM "FOR PILOTED MILITARY AIRCRAFT VOLUME...ý A1O 1 C I\\.FFBL Ti(-77-7. Vol. III f Validatio~n of UL-P-9-490D#,*. General Spacificatior "~inal 1’l -_t e for Flight ContrsA Zyn’om for Piloted...cation MIL-F-9490D (USAF), "Flight Control Systems - Design, Installation and Test of Piloted Aircraft, General Specifications for," dated 6 June 1975, by
Individual differences in posterior cortical volume correlate with proneness to pride and gratitude
Zahn, Roland; Garrido, Griselda; Moll, Jorge
2014-01-01
Proneness to specific moral sentiments (e.g. pride, gratitude, guilt, indignation) has been linked with individual variations in functional MRI (fMRI) response within anterior brain regions whose lesion leads to inappropriate behaviour. However, the role of structural anatomical differences in rendering individuals prone to particular moral sentiments relative to others is unknown. Here, we investigated grey matter volumes (VBM8) and proneness to specific moral sentiments on a well-controlled experimental task in healthy individuals. Individuals with smaller cuneus, and precuneus volumes were more pride-prone, whereas those with larger right inferior temporal volumes experienced gratitude more readily. Although the primary analysis detected no associations with guilt- or indignation-proneness, subgenual cingulate fMRI responses to guilt were negatively correlated with grey matter volumes in the left superior temporal sulcus and anterior dorsolateral prefrontal cortices (right >left). This shows that individual variations in functional activations within critical areas for moral sentiments were not due to grey matter volume differences in the same areas. Grey matter volume differences between healthy individuals may nevertheless play an important role by affecting posterior cortical brain systems that are non-critical but supportive for the experience of specific moral sentiments. This may be of particular relevance when their experience depends on visuo-spatial elaboration. PMID:24106333
Bili, Eleni; Bili, Authors Eleni; Dampala, Kaliopi; Iakovou, Ioannis; Tsolakidis, Dimitrios; Giannakou, Anastasia; Tarlatzis, Basil C
2014-08-01
The aim of this study was to determine the performance of prostate specific antigen (PSA) and ultrasound parameters, such as ovarian volume and outline, in the diagnosis of polycystic ovary syndrome (PCOS). This prospective, observational, case-controlled study included 43 women with PCOS, and 40 controls. Between day 3 and 5 of the menstrual cycle, fasting serum samples were collected and transvaginal ultrasound was performed. The diagnostic performance of each parameter [total PSA (tPSA), total-to-free PSA ratio (tPSA:fPSA), ovarian volume, ovarian outline] was estimated by means of receiver operating characteristic (ROC) analysis, along with area under the curve (AUC), threshold, sensitivity, specificity as well as positive (+) and negative (-) likelihood ratios (LRs). Multivariate logistical regression models, using ovarian volume and ovarian outline, were constructed. The tPSA and tPSA:fPSA ratio resulted in AUC of 0.74 and 0.70, respectively, with moderate specificity/sensitivity and insufficient LR+/- values. In the multivariate logistic regression model, the combination of ovarian volume and outline had a sensitivity of 97.7% and a specificity of 97.5% in the diagnosis of PCOS, with +LR and -LR values of 39.1 and 0.02, respectively. In women with PCOS, tPSA and tPSA:fPSA ratio have similar diagnostic performance. The use of a multivariate logistic regression model, incorporating ovarian volume and outline, offers very good diagnostic accuracy in distinguishing women with PCOS patients from controls. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Spaceflight Human System Standards
NASA Technical Reports Server (NTRS)
Holubec, Keith; Tillman, Barry; Connolly, Jan
2009-01-01
NASA created a new approach for human system integration and human performance standards. NASA created two documents a standard and a reference handbook. The standard is titled NASA Space Flight Human-System Standard (SFHSS) and consists of two-volumes: Volume 1- Crew Health This volume covers standards needed to support astronaut health (medical care, nutrition, sleep, exercise, etc.) Volume 2 Human Factors, Habitability and Environmental Health This volume covers the standards for system design that will maintain astronaut performance (ie., environmental factors, design of facilities, layout of workstations, and lighting requirements). It includes classic human factors requirements. The new standards document is written in terms so that it is applicable to a broad range of present and future NASA systems. The document states that all new programs prepare system-specific requirements that will meet the general standards. For example, the new standard does not specify a design should accommodate specific percentiles of a defined population. Rather, NASA-STD-3001, Volume 2 states that all programs shall prepare program-specific requirements that define the user population and their size ranges. The design shall then accommodate the full size range of those users. The companion reference handbook, Human Integration Design Handbook (HIDH), was developed to capture the design consideration information from NASA-STD-3000, and adds spaceflight lessons learned, gaps in knowledge, example solutions, and suggests research to further mature specific disciplines. The HIDH serves two major purposes: HIDH is the reference document for writing human factors requirements for specific systems. HIDH contains design guidance information that helps insure that designers create systems which safely and effectively accommodate the capabilities and limitations of space flight crews.
DOT National Transportation Integrated Search
1999-02-01
This report (FHWA-RD-98-155), the first of a four-volume set of reports, presents guidelines and recommendations to assist a highway agency in developing and using performance-related specifications for portland cement concrete pavement construction....
Mod-5A wind turbine generator program design report. Volume 4: Drawings and specifications, book 4
NASA Technical Reports Server (NTRS)
1984-01-01
The design, development and analysis of the 7.3 MW MOD-5A wind turbine generator are documented. There are four volumes. This volume contains the drawings and specifications that were developed in preparation for building the MOD-5A wind turbine generator. This volume contains 5 books of which this is the fourth, providing drawings 47A380128 through 47A387125. In addition to the parts listing and where-used list, the logic design of the controller software and the code listing of the controller software are provided. Also given are the aerodynamic profile coordinates.
Mod-5A wind turbine generator program design report. Volume 4: Drawings and specifications, book 2
NASA Technical Reports Server (NTRS)
1984-01-01
The design, development and analysis of the 7.3 MW MOD-5A wind turbine generator is documented. There are four volumes. This volume contains the drawings and specifications that were developed in preparation for building the MOD-5A wind turbine generator. This is the second book of volume four. Some of the items it contains are specs for the emergency shutdown panel, specs for the simulator software, simulator hardware specs, site operator terminal requirements, control data system requirements, software project management plan, elastomeric teeter bearing requirement specs, specs for the controls electronic cabinet, and specs for bolt pretensioning.
Draft Site Treatment Plan (DSTP), Volumes I and II
DOE Office of Scientific and Technical Information (OSTI.GOV)
D`Amelio, J.
1994-08-30
Site Treatment Plans (STP) are required for facilities at which the DOE generates or stores mixed waste. This Draft Site Treatment Plan (DSTP) the second step in a three-phase process, identifies the currently preferred options for treating mixed waste at the Savannah River Site (SRS) or for developing treatment technologies where technologies do not exist or need modification. The DSTP reflects site-specific preferred options, developed with the state`s input and based on existing available information. To the extent possible, the DSTP identifies specific treatment facilities for treating the mixed waste and proposes schedules. Where the selection of specific treatment facilitiesmore » is not possible, schedules for alternative activities such as waste characterization and technology assessment are provided. All schedule and cost information presented is preliminary and is subject to change. The DSTP is comprised of two volumes: this Compliance Plan Volume and the Background Volume. This Compliance Plan Volume proposes overall schedules with target dates for achieving compliance with the land disposal restrictions (LDR) of RCRA and procedures for converting the target dates into milestones to be enforced under the Order. The more detailed discussion of the options contained in the Background Volume is provided for informational purposes only.« less
NASA Technical Reports Server (NTRS)
Ohsaka, K.; Chung, S. K.; Rhim, W. K.
1997-01-01
The specific volumes and viscosities of the Ni-Zr liquid alloys as a function of temperature are determined by employing a digitizing technique and numeric analysis methods applied to the optical images of the electrostatically levitated liquid alloys.
Optimization of the performance of the polymerase chain reaction in silicon-based microstructures.
Taylor, T B; Winn-Deen, E S; Picozza, E; Woudenberg, T M; Albin, M
1997-01-01
We have demonstrated the ability to perform real-time homogeneous, sequence specific detection of PCR products in silicon microstructures. Optimal design/ processing result in equivalent performance (yield and specificity) for high surface-to-volume silicon structures as compared to larger volume reactions in polypropylene tubes. Amplifications in volumes as small as 0.5 microl and thermal cycling times reduced as much as 5-fold from that of conventional systems have been demonstrated for the microstructures. PMID:9224619
Converting wood volume to biomass for pinyon and juniper. Forest Service research note
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chojnacky, D.C.; Moisen, G.G.
1993-03-01
A technique was developed to convert pinyon-juniper volume equation predictions to weights. The method uses specific gravity and biomass conversion equations to obtain foliage weight and total wood weight of all stems, branches, and bark. Specific gravity data are given for several Arizona pinyon-juniper species. Biomass conversion equations are constructed from pinyon-juniper data collected in Nevada. Results provide an interim means of estimating pinyon-juniper aboveground biomass from available volume inventory data.
Zaitchik, Deborah; Solomon, Gregg E A
2009-09-01
Two studies investigated whether patients with Alzheimer's disease (AD) suffer high-level and category-specific impairment in the conceptual domain of living things. In Experiment 1, AD patients and healthy young and healthy elderly controls took part in three tasks: the conservation of species, volume, and belief. All 3 tasks required tracking an object's identity in the face of irrelevant but salient transformations. Healthy young and elderly controls performed at or near ceiling on all tasks. AD patients were at or near ceiling on the volume and belief tasks, but only about half succeeded on the species task. Experiment 2 demonstrated that the results were not due to simple task demands. AD patients' failure to conserve species indicates that they are impaired in their theoretical understanding of living things, and their success on the volume and belief tasks suggests that the impairment is domain-specific. Two hypotheses are put forward to explain the phenomenon: The first, a category-specific account, holds that the intuitive theory of biology undergoes pervasive degradation; the second, a hybrid domain-general/domain-specific account, holds that impairment to domain-general processes such as executive function interacts with core cognition, the primitive elements that are the foundation of domain-specific knowledge.
Zaitchik, Deborah; Solomon, Gregg E. A.
2009-01-01
Two studies investigated whether patients with Alzheimer’s disease (AD) suffer high-level and category-specific impairment in the conceptual domain of living things. In Study 1, AD patients and healthy young and healthy elderly controls took part in three tasks: the Conservation of Species, Volume, and Belief. All 3 tasks required tracking an object’s identity in the face of irrelevant but salient transformations. Healthy young and elderly controls performed at or near ceiling on all tasks. AD patients were at or near ceiling on the Volume and Belief tasks, but only about half succeeded on the Species task. Study 2 demonstrated that the results were not due to simple task demands. AD patients’ failure to conserve species indicates that they are impaired in their theoretical understanding of living things, and their success on the Volume and Belief tasks suggests that the impairment is domain-specific. Two hypotheses are put forward to explain the phenomenon: the first, a category-specific account, holds that the intuitive theory of biology undergoes pervasive degradation; the second, a hybrid domain-general/domain-specific account, holds that impairment to domain-general processes such as executive function interacts with core cognition, the primitive elements that are the foundation of domain-specific knowledge. PMID:20043252
Thermodynamic properties derived from the free volume model of liquids
NASA Technical Reports Server (NTRS)
Miller, R. I.
1974-01-01
An equation of state and expressions for the isothermal compressibility, thermal expansion coefficient, heat capacity, and entropy of liquids have been derived from the free volume model partition function suggested by Turnbull. The simple definition of the free volume is used, and it is assumed that the specific volume is directly related to the cube of the intermolecular separation by a proportionality factor which is found to be a function of temperature and pressure as well as specific volume. When values of the proportionality factor are calculated from experimental data for real liquids, it is found to be approximately constant over ranges of temperature and pressure which correspond to the dense liquid phase. This result provides a single-parameter method for calculating dense liquid thermodynamic properties and is consistent with the fact that the free volume model is designed to describe liquids near the solidification point.
Strategies for hydration and energy provision during soccer-specific exercise.
Clarke, N D; Drust, B; MacLaren, D P M; Reilly, T
2005-12-01
The aim of the present study was to investigate the effect of manipulating the provision of sports drink during soccer-specific exercise on metabolism and performance. Soccer players (N = 12) performed a soccer-specific protocol on three occasions. On two, 7 mL/kg carbohydrate-electrolyte (CHOv) or placebo (PLA) solutions were ingested at 0 and 45 min. On a third, the same total volume of carbohydrate-electrolyte was consumed (CHOf) in smaller volumes at 0, 15, 30, 45, 60, and 75 min. Plasma glucose, glycerol, non-esterified free fatty acids (NEFA), cortisol, and CHO oxidation were not significantly different between CHOv and CHOf (P > 0.05). Sprint power was not significantly affected (P > 0.05) by the experimental trials. This study demonstrates when the total volume of carbohydrate consumed is equal, manipulating the timing and volume of ingestion elicits similar metabolic responses without affecting exercise performance.
Handbook of Parenting. Volume 2: Biology and Ecology of Parenting.
ERIC Educational Resources Information Center
Bornstein, Marc H., Ed.
Concerned with social settings and correlates of parenting, this volume, the second of four volumes on parenting deals specifically with the biology and the ecology of parenting. The volume consists of 12 chapters as follows: (1) "Hormonal Basis of Parenting in Mammals" (Jay S. Rosenblatt); (2) "Parenting in Primates" (Kim A.…
Handbook of Parenting. Volume 2: Biology and Ecology of Parenting. Second Edition.
ERIC Educational Resources Information Center
Bornstein, Marc H., Ed.
Concerned with social settings and correlates of parenting, this volume, the second of five volumes on parenting, deals specifically with the biological and the contextual influences on parenting. The volume consists of the following 12 chapters: (1) "The Evolution of Parenting and Evolutionary Approaches to Childrearing" (David F.…
Handbook of Parenting. Volume 1: Children and Parenting. Second Edition.
ERIC Educational Resources Information Center
Bornstein, Marc H., Ed.
Concerned with different types of parents and the forces that shape parenting, this volume, the first of five volumes on parenting, deals specifically with parent-child relationships throughout the lifespan and the parenting of children of different physical, behavioral, and intellectual needs. The volume consists of the following 14 chapters: (1)…
Handbook of Parenting. Volume 1: Children and Parenting.
ERIC Educational Resources Information Center
Bornstein, Marc H., Ed.
Concerned with different types of parents and the forces that shape parenting, this volume, the first of four volumes on parenting deals specifically with parent-child relationships throughout the lifespan and the parenting of children of different physical, behavioral, and intellectual needs. The volume consists of 12 chapters as follows: (1)…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peach, D.F.
1987-12-01
Fiber optic telecommunication systems are susceptible to both natural and man-made stress. National Security/Emergency Preparedness (NSEP) is a function of how durable these systems are in light of projected levels of stress. Emergency Preparedness in 1987 is not just a matter of--can they deliver food, water, energy and other essentials--but can they deliver the vital information necessary to maintain corporate function of our country. 'Communication stamina' is a function of 'probability of survival' when faced with stress. This report provides an overview of the enhancements to a fiber-optic communication system/installation that will increase durability. These enhancements are grouped, based onmore » their value in protecting the system, such that a Multitier Specification is created that presents multiple levels of hardness. Mitigation of effects due to high-altitude electromagnetic pulse (HEMP) and gamma radiation, and protection from vandalism and weather events are discussed in the report. The report is presented in two volumes. Volume I presents the Multitier Specification in a format that is usable for management review. The attributes of specified physical parameters, and the levels of protection stated in Volume I, are discussed in more detail in Volume II.« less
Nemeth, Gabor; Szalai, Eszter; Hassan, Ziad; Lipecz, Agnes; Flasko, Zsuzsa; Modis, Laszlo
2017-01-01
AIM To analyze the correlations between ocular biomechanical and biometric data of the eye, measured by Scheimpflug-based devices on healthy subjects. METHODS Three consecutive measurements were carried out using the corneal visualization Scheimpflug technology (CorVis ST) device on healthy eyes and the 10 device-specific parameters were recorded. Pentacam HR-derived parameters (corneal curvature radii on the anterior and posterior surfaces; apical pachymetry; corneal volume; corneal aberration data; depth, volume and angle of the anterior chamber) and axial length (AL) from IOLMaster were correlated with the 10 specific CorVis ST parameters. RESULTS Measurements were conducted in 43 eyes of 43 volunteers (age 61.24±15.72y). The 10 specific CorVis ST data showed significant relationships with corneal curvature radii both on the anterior and posterior surface, pachymetric data, root mean square (RMS) data of lower-order aberrations, and posterior RMS of higher-order aberrations and spherical aberration of the posterior cornea. Anterior chamber depth showed a significant relationship, but there were no significant correlations between corneal volume, anterior chamber volume, mean chamber angle or AL and the 10 specific CorVis ST parameters. CONCLUSIONS CorVis ST-generated parameters are influenced by corneal curvature radii, some corneal RMS data, but corneal volume, anterior chamber volume, chamber angle and AL have no correlation with the biomechanical parameters. The parameters measured by CorVis ST seem to refer mostly to corneal properties of the eye. PMID:28251079
Nemeth, Gabor; Szalai, Eszter; Hassan, Ziad; Lipecz, Agnes; Flasko, Zsuzsa; Modis, Laszlo
2017-01-01
To analyze the correlations between ocular biomechanical and biometric data of the eye, measured by Scheimpflug-based devices on healthy subjects. Three consecutive measurements were carried out using the corneal visualization Scheimpflug technology (CorVis ST) device on healthy eyes and the 10 device-specific parameters were recorded. Pentacam HR-derived parameters (corneal curvature radii on the anterior and posterior surfaces; apical pachymetry; corneal volume; corneal aberration data; depth, volume and angle of the anterior chamber) and axial length (AL) from IOLMaster were correlated with the 10 specific CorVis ST parameters. Measurements were conducted in 43 eyes of 43 volunteers (age 61.24±15.72y). The 10 specific CorVis ST data showed significant relationships with corneal curvature radii both on the anterior and posterior surface, pachymetric data, root mean square (RMS) data of lower-order aberrations, and posterior RMS of higher-order aberrations and spherical aberration of the posterior cornea. Anterior chamber depth showed a significant relationship, but there were no significant correlations between corneal volume, anterior chamber volume, mean chamber angle or AL and the 10 specific CorVis ST parameters. CorVis ST-generated parameters are influenced by corneal curvature radii, some corneal RMS data, but corneal volume, anterior chamber volume, chamber angle and AL have no correlation with the biomechanical parameters. The parameters measured by CorVis ST seem to refer mostly to corneal properties of the eye.
Huang, Xinru; Roth, Connie B
2016-06-21
Recent studies have measured or predicted thickness-dependent shifts in density or specific volume of polymer films as a possible means of understanding changes in the glass transition temperature Tg(h) with decreasing film thickness with some experimental works claiming unrealistically large (25%-30%) increases in film density with decreasing thickness. Here we use ellipsometry to measure the temperature-dependent index of refraction of polystyrene (PS) films supported on silicon and investigate the validity of the commonly used Lorentz-Lorenz equation for inferring changes in density or specific volume from very thin films. We find that the density (specific volume) of these supported PS films does not vary by more than ±0.4% of the bulk value for film thicknesses above 30 nm, and that the small variations we do observe are uncorrelated with any free volume explanation for the Tg(h) decrease exhibited by these films. We conclude that the derivation of the Lorentz-Lorenz equation becomes invalid for very thin films as the film thickness approaches ∼20 nm, and that reports of large density changes greater than ±1% of bulk for films thinner than this likely suffer from breakdown in the validity of this equation or in the difficulties associated with accurately measuring the index of refraction of such thin films. For larger film thicknesses, we do observed small variations in the effective specific volume of the films of 0.4 ± 0.2%, outside of our experimental error. These shifts occur simultaneously in both the liquid and glassy regimes uniformly together starting at film thicknesses less than ∼120 nm but appear to be uncorrelated with Tg(h) decreases; possible causes for these variations are discussed.
Porosity control in nanoporous carbide-derived carbon by oxidation in air and carbon dioxide
DOE Office of Scientific and Technical Information (OSTI.GOV)
Osswald, S.; Portet, C.; Gogotsi, Y., E-mail: gogotsi@drexel.ed
2009-07-15
Carbide-derived carbons (CDC) allow a precise control over the pore size through the selection of the carbide precursor and varying of the synthesis conditions. However, their pore volume is limited by the carbide stoichiometry. While activation of carbons derived from various organic precursors has been widely studied, this process may similarly be able to increase the pore volume and specific surface area of CDC. Oxidation of carbide-derived carbon in air and CO{sub 2} at different temperatures and times allows for significant increase in pore volume and specific surface area as well as control over average pore size with subnanometer accuracy.more » The effect of activation and associated changes in the pore volume and surface area on the hydrogen uptake are also discussed. - Graphical abstract: Carbide-derived carbons (CDC) provide great potential for sorption of toxicants and gas storage applications. Activation of CDC in air and CO{sub 2} at different temperatures and times is applied in order to maximize pore volume and specific surface area, and control the average pore size with subnanometer accuracy.« less
Macular Diagnostic Ability in OCT for Assessing Glaucoma in High Myopia.
Hung, Kuo-Chi; Wu, Pei-Chang; Poon, Yi-Chieh; Chang, Hsueh-Wen; Lai, Ing-Chou; Tsai, Jen-Chia; Lin, Pei-Wen; Teng, Mei-Ching
2016-02-01
To compare the diagnostic abilities of spectral-domain optical coherence tomography (SD-OCT; Spectralis OCT) and time-domain OCT (TD-OCT; Stratus OCT). Changes in macular parameters in highly myopic eyes of glaucoma patients and highly myopic eyes of glaucoma suspects were evaluated and compared. We collected data from 72 highly myopic eyes (spherical equivalent, ≤-6.0D). Forty-one eyes had perimetric glaucoma and 31 eyes were suspected to have glaucoma (control group). All eyes underwent SD-OCT and TD-OCT imaging. Area under the receiver operating characteristic (AUROC) curve and sensitivity were examined on macular volume and thickness parameters at a fixed specificity and compared between groups. The highest TD-OCT AUROC curves were found using outer inferior sector macular thickness (AUROC curve, 0.911) and volume (AUROC curve, 0.909). The highest SD-OCT AUROC curves were found using outer inferior region thickness (AUROC curve, 0.836) and volume (AUROC curve, 0.834). The difference between the two imaging modalities was not statistically significant (thickness, p = 0.141; volume, p = 0.138). The sensitivity of TD-OCT macular outer inferior average thickness was highest and was 88.2%, with a specificity of 80.4%. The sensitivity of TD-OCT average volume measurements in this same region was 76.5%, with a specificity of 91.3%. The SD-OCT average thickness measurements also had the highest sensitivity in this region, which was 78.6%, with a specificity of 82.1%. The SD-OCT volume measurements had a sensitivity of 67.9%, with a specificity of 92.3%. Both SD-OCT and TD-OCT measurements of outer inferior macular thickness and volume can differentiate between eyes of glaucoma patients and glaucoma suspects with high myopia. These independent predictors all had good sensitivity. Based on our results, SD-OCT and TD-OCT have similar diagnostic abilities. These parameters may provide useful additional data in highly myopic eyes to complement standard glaucoma diagnosis tools.
ERIC Educational Resources Information Center
Weisburd, Melvin I.
The Field Operations and Enforcement Manual for Air Pollution Control, Volume III, explains in detail the following: inspection procedures for specific sources, kraft pulp mills, animal rendering, steel mill furnaces, coking operations, petroleum refineries, chemical plants, non-ferrous smelting and refining, foundries, cement plants, aluminum…
Individual differences in posterior cortical volume correlate with proneness to pride and gratitude.
Zahn, Roland; Garrido, Griselda; Moll, Jorge; Grafman, Jordan
2014-11-01
Proneness to specific moral sentiments (e.g. pride, gratitude, guilt, indignation) has been linked with individual variations in functional MRI (fMRI) response within anterior brain regions whose lesion leads to inappropriate behaviour. However, the role of structural anatomical differences in rendering individuals prone to particular moral sentiments relative to others is unknown. Here, we investigated grey matter volumes (VBM8) and proneness to specific moral sentiments on a well-controlled experimental task in healthy individuals. Individuals with smaller cuneus, and precuneus volumes were more pride-prone, whereas those with larger right inferior temporal volumes experienced gratitude more readily. Although the primary analysis detected no associations with guilt- or indignation-proneness, subgenual cingulate fMRI responses to guilt were negatively correlated with grey matter volumes in the left superior temporal sulcus and anterior dorsolateral prefrontal cortices (right >left). This shows that individual variations in functional activations within critical areas for moral sentiments were not due to grey matter volume differences in the same areas. Grey matter volume differences between healthy individuals may nevertheless play an important role by affecting posterior cortical brain systems that are non-critical but supportive for the experience of specific moral sentiments. This may be of particular relevance when their experience depends on visuo-spatial elaboration. Published by Oxford University Press 2013. This work is written by US Government employees and is in the public domain in the US.
Density Contrast Sedimentation Velocity for the Determination of Protein Partial-Specific Volumes
Brown, Patrick H.; Balbo, Andrea; Zhao, Huaying; Ebel, Christine; Schuck, Peter
2011-01-01
The partial-specific volume of proteins is an important thermodynamic parameter required for the interpretation of data in several biophysical disciplines. Building on recent advances in the use of density variation sedimentation velocity analytical ultracentrifugation for the determination of macromolecular partial-specific volumes, we have explored a direct global modeling approach describing the sedimentation boundaries in different solvents with a joint differential sedimentation coefficient distribution. This takes full advantage of the influence of different macromolecular buoyancy on both the spread and the velocity of the sedimentation boundary. It should lend itself well to the study of interacting macromolecules and/or heterogeneous samples in microgram quantities. Model applications to three protein samples studied in either H2O, or isotopically enriched H2 18O mixtures, indicate that partial-specific volumes can be determined with a statistical precision of better than 0.5%, provided signal/noise ratios of 50–100 can be achieved in the measurement of the macromolecular sedimentation velocity profiles. The approach is implemented in the global modeling software SEDPHAT. PMID:22028836
Duin, L K; Nijhuis, J G; Scherjon, S A; Vossen, M; Willekes, C
2016-01-01
To establish a threshold value for fetal renal pelvis dilatation measured by automatic volume calculation (SonoAVC) in the third trimester of pregnancy to predict neonatal uropathies, and to compare these results with conventional antero-posterior (AP) measurement, fetal kidney 3D volume and renal parenchymal thickness. In a prospective cohort study, 125 fetuses with renal pelvis AP diameter of ≥5 mm both at 20 weeks of gestation and in the third trimester, underwent an additional 3D volume measurement of the fetal kidney in the third trimester. Receiver operating characteristic (ROC) curves for establishing threshold values for fetal renal pelvis volume, AP measurement, fetal kidney volume and renal parenchymal thickness to predict neonatal uropathies were analyzed. Also, sensitivity, specificity, area under the curve (AUC) and likelihood ratios were calculated. A cut-off point of 1.58 cm³ was identified in the third trimester of pregnancy (AUC 0.865 (95% CI 0.789-0.940), sensitivity 76.3%, specificity 87.4%, LR+ 6.06, LR- 0.27) for measurements with SonoAVC. A cut-off value of 11.5 mm was established in the third trimester of pregnancy (AUC 0.828 (95% CI 0.737-0.918), sensitivity 71.1%, specificity 85.1%, LR+ 4.77, LR- 0.34) for the conventional AP measurement. A cut-off point for fetal kidney volume was calculated at 13.29 cm³ (AUC 0.769 (95% CI 0.657-0.881), sensitivity 71%, specificity 66%, LR+ 2.09, LR- 0.44). For renal parenchymal thickness, a cut-off point of 8.4 mm was established (AUC 0.216 (95% CI 0.117-0.315), sensitivity 31.6%, specificity 32.6%, LR+ 0.47, LR- 2.10). This study demonstrates that 3D fetal renal pelvis volume measurements and AP measurements both have a good and comparable diagnostic performance, fetal renal volume a fair accuracy and renal parenchymal thickness a poor accuracy in predicting postnatal renal outcome.
Operations and safety of Super 2 corridors with higher volumes.
DOT National Transportation Integrated Search
2011-06-01
As traffic volumes increase, in both urban and rural areas, the demand on the highway network also : increases. Specifically, as rural traffic volumes rise in Texas, the pressure on the states network of two-lane : highways rises accordingly. Prev...
Beam-specific planning volumes for scattered-proton lung radiotherapy
NASA Astrophysics Data System (ADS)
Flampouri, S.; Hoppe, B. S.; Slopsema, R. L.; Li, Z.
2014-08-01
This work describes the clinical implementation of a beam-specific planning treatment volume (bsPTV) calculation for lung cancer proton therapy and its integration into the treatment planning process. Uncertainties incorporated in the calculation of the bsPTV included setup errors, machine delivery variability, breathing effects, inherent proton range uncertainties and combinations of the above. Margins were added for translational and rotational setup errors and breathing motion variability during the course of treatment as well as for their effect on proton range of each treatment field. The effect of breathing motion and deformation on the proton range was calculated from 4D computed tomography data. Range uncertainties were considered taking into account the individual voxel HU uncertainty along each proton beamlet. Beam-specific treatment volumes generated for 12 patients were used: a) as planning targets, b) for routine plan evaluation, c) to aid beam angle selection and d) to create beam-specific margins for organs at risk to insure sparing. The alternative planning technique based on the bsPTVs produced similar target coverage as the conventional proton plans while better sparing the surrounding tissues. Conventional proton plans were evaluated by comparing the dose distributions per beam with the corresponding bsPTV. The bsPTV volume as a function of beam angle revealed some unexpected sources of uncertainty and could help the planner choose more robust beams. Beam-specific planning volume for the spinal cord was used for dose distribution shaping to ensure organ sparing laterally and distally to the beam.
ERIC Educational Resources Information Center
Construction Systems Management, Inc., Anchorage, AK.
Volume II of a 3-volume report demonstrates the use of Design Determinants and Options (presented in Volume I) in the planning and design of small rural Alaskan secondary schools. Section I, a checklist for gathering site-specific information to be used as a data base for facility design, is organized in the same format as Volume I, which can be…
Surgeon specialization and operative mortality in United States: retrospective analysis
Dalton, Maurice; Cutler, David M; Birkmeyer, John D; Chandra, Amitabh
2016-01-01
Objective To measure the association between a surgeon’s degree of specialization in a specific procedure and patient mortality. Design Retrospective analysis of Medicare data. Setting US patients aged 66 or older enrolled in traditional fee for service Medicare. Participants 25 152 US surgeons who performed one of eight procedures (carotid endarterectomy, coronary artery bypass grafting, valve replacement, abdominal aortic aneurysm repair, lung resection, cystectomy, pancreatic resection, or esophagectomy) on 695 987 patients in 2008-13. Main outcome measure Relative risk reduction in risk adjusted and volume adjusted 30 day operative mortality between surgeons in the bottom quarter and top quarter of surgeon specialization (defined as the number of times the surgeon performed the specific procedure divided by his/her total operative volume across all procedures). Results For all four cardiovascular procedures and two out of four cancer resections, a surgeon’s degree of specialization was a significant predictor of operative mortality independent of the number of times he or she performed that procedure: carotid endarterectomy (relative risk reduction between bottom and top quarter of surgeons 28%, 95% confidence interval 0% to 48%); coronary artery bypass grafting (15%, 4% to 25%); valve replacement (46%, 37% to 53%); abdominal aortic aneurysm repair (42%, 29% to 53%); lung resection (28%, 5% to 46%); and cystectomy (41%, 8% to 63%). In five procedures (carotid endarterectomy, valve replacement, lung resection, cystectomy, and esophagectomy), the relative risk reduction from surgeon specialization was greater than that from surgeon volume for that specific procedure. Furthermore, surgeon specialization accounted for 9% (coronary artery bypass grafting) to 100% (cystectomy) of the relative risk reduction otherwise attributable to volume in that specific procedure. Conclusion For several common procedures, surgeon specialization was an important predictor of operative mortality independent of volume in that specific procedure. When selecting a surgeon, patients, referring physicians, and administrators assigning operative workload may want to consider a surgeon’s procedure specific volume as well as the degree to which a surgeon specializes in that procedure. PMID:27444190
ERIC Educational Resources Information Center
Utah Univ., Salt Lake City. Human Resources Inst.
Volume 2, which accompanies "Mechanisms for Aiding Worker Adjustment to Technological Change, Volume 1," consists of a key word index for locating specific topics and the abstracts of literature reviewed in Volume 1. Key words, referring to aspects of worker adjustment to technological change appearing in the abstracted literature, are grouped…
Ramskov, Daniel; Rasmussen, Sten; Sørensen, Henrik; Parner, Erik Thorlund; Lind, Martin; Nielsen, Rasmus
2018-06-12
Study Design Randomized clinical trial, etiology. Background Training intensity and volume have been proposed to be associated with specific running-related injuries. If such an association exists, secondary preventive measures could be initiated by clinicians based on symptoms of a specific injury diagnosis. Objectives To test the following hypotheses: (i) A running schedule focusing on intensity will increase the risk of sustaining Achilles tendinopathy, gastrocnemius injuries and plantar fasciitis compared with hypothesized volume-related injuries. (ii) A running schedule focusing on running volume will increase the risk of sustaining patellofemoral pain syndrome, iliotibial band syndrome and patellar tendinopathy compared with hypothesized intensity-related injuries. Methods Healthy recreational runners were included in a 24-week follow-up, divided into 8-week preconditioning and 16-week specific focus-training. Participants were randomized to one of two running schedules: Schedule Intensity(Sch-I) or Schedule Volume(Sch-V). Sch-I progressed the amount of high intensity running (≥88% VO2max) each week. Sch-V progressed total weekly running volume. Global positioning system watch or smartphone collected data on running. Running-related injuries were diagnosed based on a clinical examination. Estimates were risk difference (RD) and 95%CI. Results Of 447 runners, a total of 80 sustained an injury (Sch-I n=36; Sch-V n=44). Risk of intensity injuries in Sch-I were: RD 2-weeks =-0.8%[-5.0;3.4]; RD 4-weeks =-0.8%[-6.7;5.1]; RD 8-weeks =-2.0%[-9.2;5.1]; RD 16-weeks =-5.1%[-16.5;6.3]. Risk of volume injuries in Sch-V were: RD 2-weeks =-0.9%[-5.0;3.2]; RD 4-weeks =-2.0%[-7.5;3.5]; RD 8-weeks =-3.2%[-9.1;2.7]; RD 16-weeks =-3.4%[-13.2;6.2]. Conclusion No difference in risk of hypothesized intensity and volume specific running-related injuries exist between running schedules focused on progression in either running intensity or volume. Level of Evidence Etiology, level 1b. J Orthop Sports Phys Ther, Epub 12 Jun 2018. doi:10.2519/jospt.2018.8062.
Mod-5A wind turbine generator program design report. Volume 4: Drawings and specifications, book 1
NASA Astrophysics Data System (ADS)
1984-08-01
The design, development and analysis of the 7.3 MW MOD-5A wind turbine generator is documented. Volume 4 contains the drawings and specifications that were developed in preparation for building the MOD-5A wind turbine generator. This is the first of five books of volume four. It contains structural design criteria, generator step-up transformer specs, specs for design, fabrication and testing of the system, specs for the ground control enclosure, systems specs, slip ring specs, and control system specs.
Mod-5A Wind Turbine Generator Program Design Report. Volume 4: Drawings and Specifications, Book 1
NASA Technical Reports Server (NTRS)
1984-01-01
The design, development and analysis of the 7.3 MW MOD-5A wind turbine generator is documented. Volume 4 contains the drawings and specifications that were developed in preparation for building the MOD-5A wind turbine generator. This is the first of five books of volume four. It contains structural design criteria, generator step-up transformer specs, specs for design, fabrication and testing of the system, specs for the ground control enclosure, systems specs, slip ring specs, and control system specs.
CD volume design and verification
NASA Technical Reports Server (NTRS)
Li, Y. P.; Hughes, J. S.
1993-01-01
In this paper, we describe a prototype for CD-ROM volume design and verification. This prototype allows users to create their own model of CD volumes by modifying a prototypical model. Rule-based verification of the test volumes can then be performed later on against the volume definition. This working prototype has proven the concept of model-driven rule-based design and verification for large quantity of data. The model defined for the CD-ROM volumes becomes a data model as well as an executable specification.
Regional grey matter volume abnormalities in bulimia nervosa and binge-eating disorder.
Schäfer, Axel; Vaitl, Dieter; Schienle, Anne
2010-04-01
This study investigated whether bulimia nervosa (BN) and binge-eating disorder (BED) are associated with structural brain abnormalities. Both disorders share the main symptom binge-eating, but are considered differential diagnoses. We attempted to identify alterations in grey matter volume (GMV) that are present in both psychopathologies as well as disorder-specific GMV characteristics. Such information can help to improve neurobiological models of eating disorders and their classification. A total of 50 participants (patients suffering from BN (purge type), BED, and normal-weight controls) underwent structural MRI scanning. GMV for specific brain regions involved in food/reinforcement processing was analyzed by means of voxel-based morphometry. Both patient groups were characterized by greater volumes of the medial orbitofrontal cortex (OFC) compared to healthy controls. In BN patients, who had increased ventral striatum volumes, body mass index and purging severity were correlated with striatal grey matter volume. Altogether, our data implicate a crucial role of the medial OFC in the studied eating disorders. The structural abnormality might be associated with dysfunctions in food reward processing and/or self-regulation. The bulimia-specific volume enlargement of the ventral striatum is discussed in the framework of negative reinforcement through purging and associated weight regulation. Copyright 2009 Elsevier Inc. All rights reserved.
Accuracy of Screening Mammography Interpretation by Characteristics of Radiologists
Barlow, William E.; Chi, Chen; Carney, Patricia A.; Taplin, Stephen H.; D’Orsi, Carl; Cutter, Gary; Hendrick, R. Edward; Elmore, Joann G.
2011-01-01
Background Radiologists differ in their ability to interpret screening mammograms accurately. We investigated the relationship of radiologist characteristics to actual performance from 1996 to 2001. Methods Screening mammograms (n = 469 512) interpreted by 124 radiologists were linked to cancer outcome data. The radiologists completed a survey that included questions on demographics, malpractice concerns, years of experience interpreting mammograms, and the number of mammograms read annually. We used receiver operating characteristics (ROC) analysis to analyze variables associated with sensitivity, specificity, and the combination of the two, adjusting for patient variables that affect performance. All P values are two-sided. Results Within 1 year of the mammogram, 2402 breast cancers were identified. Relative to low annual interpretive volume (≤1000 mammograms), greater interpretive volume was associated with higher sensitivity (P = .001; odds ratio [OR] for moderate volume [1001–2000] = 1.68, 95% CI = 1.18 to 2.39; OR for high volume [>2000] = 1.89, 95% CI = 1.36 to 2.63). Specificity decreased with volume (OR for 1001–2000 = 0.65, 95% CI = 0.52 to 0.83; OR for more than 2000 = 0.76, 95% CI = 0.60 to 0.96), compared with 1000 or less (P = .002). Greater number of years of experience interpreting mammograms was associated with lower sensitivity (P = .001), but higher specificity (P = .003). ROC analysis using the ordinal BI-RADS interpretation showed an association between accuracy and both previous mammographic history (P = .012) and breast density (P<.001). No association was observed between accuracy and years interpreting mammograms (P = .34) or mammography volume (P = .94), after adjusting for variables that affect the threshold for calling a mammogram positive. Conclusions We found no evidence that greater volume or experience at interpreting mammograms is associated with better performance. However, they may affect sensitivity and specificity, possibly by determining the threshold for calling a mammogram positive. Increasing volume requirements is unlikely to improve overall mammography performance. PMID:15601640
Specific gravity and other properties of wood and bark for 156 tree species found in North America
Patrick D. Miles
2009-01-01
This paper reports information for the estimation of biomass for 156 tree species found in North America for use in national forest inventory applications. We present specific gravities based on average green volume as well as 12 percent moisture content volume for calculation of oven-dry biomass....
Lecture Notes on Human Anatomy. Part Two, Fourth Edition.
ERIC Educational Resources Information Center
Conrey, Kathleen
During the process of studying the specific course content of human anatomy, students are being educated to expand their vocabulary, deal successfully with complex tasks, and learn a specific way of thinking. This is the second volume in a set of notes which are designed to accompany a lecture series in human anatomy. This volume includes…
Lecture Notes on Human Anatomy. Part One, Fourth Edition.
ERIC Educational Resources Information Center
Conrey, Kathleen
During the process of studying the specific course content of human anatomy, students are being educated to expand their vocabulary, deal successfully with complex tasks, and use a specific way of thinking. This is the first volume in a set of notes which are designed to accompany a lecture series in human anatomy. This volume includes discussions…
Shuttle payload interface verification equipment study. Volume 3: Specification data
NASA Technical Reports Server (NTRS)
1976-01-01
A complete description is given of the IVE physical and performance design requirements as evolved in this study. The data are presented in a format to facilitate the development of an item specification. Data were used to support the development of the project plan data (schedules, cost, etc.) contained in Volume 4 of this report.
NASA Astrophysics Data System (ADS)
Oh, Jungsu S.; Kim, Jae Seung; Chae, Sun Young; Oh, Minyoung; Oh, Seung Jun; Cha, Seung Nam; Chang, Ho-Jong; Lee, Chong Sik; Lee, Jae Hong
2017-03-01
We present an optimized voxelwise statistical parametric mapping (SPM) of partial-volume (PV)-corrected positron emission tomography (PET) of 11C Pittsburgh Compound B (PiB), incorporating the anatomical precision of magnetic resonance image (MRI) and amyloid β (A β) burden-specificity of PiB PET. First, we applied region-based partial-volume correction (PVC), termed the geometric transfer matrix (GTM) method, to PiB PET, creating MRI-based lobar parcels filled with mean PiB uptakes. Then, we conducted a voxelwise PVC by multiplying the original PET by the ratio of a GTM-based PV-corrected PET to a 6-mm-smoothed PV-corrected PET. Finally, we conducted spatial normalizations of the PV-corrected PETs onto the study-specific template. As such, we increased the accuracy of the SPM normalization and the tissue specificity of SPM results. Moreover, lobar smoothing (instead of whole-brain smoothing) was applied to increase the signal-to-noise ratio in the image without degrading the tissue specificity. Thereby, we could optimize a voxelwise group comparison between subjects with high and normal A β burdens (from 10 patients with Alzheimer's disease, 30 patients with Lewy body dementia, and 9 normal controls). Our SPM framework outperformed than the conventional one in terms of the accuracy of the spatial normalization (85% of maximum likelihood tissue classification volume) and the tissue specificity (larger gray matter, and smaller cerebrospinal fluid volume fraction from the SPM results). Our SPM framework optimized the SPM of a PV-corrected A β PET in terms of anatomical precision, normalization accuracy, and tissue specificity, resulting in better detection and localization of A β burdens in patients with Alzheimer's disease and Lewy body dementia.
Aerospace Structures Technology Damping Design Guide. Volume 1. Technology Review
1985-12-01
AFWAL-TR-84-3089 Volume I AEROSPACE STRUCTURES TECHNOLOGY I DAMPING DESIGN GUIDE VOLUME I - TECHNOLOGY REVIEW J. SOOVERE LOCKHEED CALIFORNIA COMPANY...3089 Volume I AEROSPACE STRUCTURES TECHNOLOGY DAMPING DESIGN GUIDE VOLUME I - TECHNOLOGY REVIEW J. SOOVERE LOCKMD CALIFORNIA COMPANY P.O. BOX 551 BURBANK...PATTERSON AIR FORCE BASE, OHIO 454t33I I ft NOTICE When Government drawings, specifications, or other data are used for any purpose other than in
Longitudinal Study of Gray Matter Changes in Parkinson Disease.
Jia, X; Liang, P; Li, Y; Shi, L; Wang, D; Li, K
2015-12-01
The pathology of Parkinson disease leads to morphological brain volume changes. So far, the progressive gray matter volume change across time specific to patients with Parkinson disease compared controls remains unclear. Our aim was to investigate the pattern of gray matter changes in patients with Parkinson disease and to explore the progressive gray matter volume change specific to patients with Parkinson disease with disease progression by using voxel-based morphometry analysis. Longitudinal cognitive assessment and structural MR imaging of 89 patients with Parkinson disease (62 men) and 55 healthy controls (33 men) were from the Parkinson's Progression Markers Initiative data base, including the initial baseline and 12-month follow-up data. Two-way analysis of covariance was performed with covariates of age, sex, years of education, imaging data from multiple centers, and total intracranial volume by using Diffeomorphic Anatomical Registration Through Exponentiated Lie Algebra tool from SPM8 software. Gray matter volume changes for patients with Parkinson disease were detected with decreased gray matter volume in the frontotemporoparietal areas and the bilateral caudate, with increased gray matter volume in the bilateral limbic/paralimbic areas, medial globus pallidus/putamen, and the right occipital cortex compared with healthy controls. Progressive gray matter volume decrease in the bilateral caudate was found for both patients with Parkinson disease and healthy controls, and this caudate volume was positively associated with cognitive ability for both groups. The progressive gray matter volume increase specific to the patients with Parkinson disease was identified close to the left ventral lateral nucleus of thalamus, and a positive relationship was found between the thalamic volume and the tremor scores in a subgroup with tremor-dominant patients with Parkinson disease. The observed progressive changes in gray matter volume in Parkinson disease may provide new insights into the neurodegenerative process. The current findings suggest that the caudate volume loss may contribute to cognitive decline in patients with Parkinson disease and the progressive thalamus enlargement may have relevance to tremor severity in Parkinson disease. © 2015 by American Journal of Neuroradiology.
Korponay, Cole; Kosson, David S; Decety, Jean; Kiehl, Kent A; Koenigs, Michael
2017-10-01
Human neuroimaging studies indicate that the loss of brain volume associated with substance abuse may be recovered during abstinence. Subcortical and prefrontal cortical regions involved in reward and decision-making are among the regions most consistently implicated in damage and recovery from substance abuse, but the relative capacities of these different brain regions to recover volume during abstinence remains unclear, and it is unknown whether recovery capacities depend on the substance that was abused. Voxel-based morphometry in a prison inmate sample ( n =107) of long-term abstinent former regular users (FRUs) and former light users (FLUs) of alcohol, cocaine, and/or cannabis. Cross-sectional indicators of volume recovery were operationalized as 1) positive correlation between abstinence duration and volume in FRUs and 2) absence of lower volume in FRUs compared to FLUs. In FRUs of alcohol, abstinence duration positively correlated with volume in subcortical regions (particularly the putamen and amygdala) but not prefrontal regions; lower prefrontal but not subcortical volume was observed in FRUs compared to FLUs. In FRUs of cocaine, abstinence duration positively correlated with volume in both subcortical regions (particularly the nucleus accumbens) and prefrontal regions; lower volume was not observed in either subcortical or prefrontal regions in FRUs. In FRUs of cannabis, abstinence duration positively correlated with subcortical but not prefrontal volume; lower prefrontal but not subcortical volume was observed in FRUs. Subcortical structures displayed indicators of volume recovery across FRUs of all three substances, whereas prefrontal regions displayed indicators of volume recovery only in FRUs of cocaine.
Self-Interaction Chromatography of mAbs: Accurate Measurement of Dead Volumes.
Hedberg, S H M; Heng, J Y Y; Williams, D R; Liddell, J M
2015-12-01
Measurement of the second virial coefficient B22 for proteins using self-interaction chromatography (SIC) is becoming an increasingly important technique for studying their solution behaviour. In common with all physicochemical chromatographic methods, measuring the dead volume of the SIC packed column is crucial for accurate retention data; this paper examines best practise for dead volume determination. SIC type experiments using catalase, BSA, lysozyme and a mAb as model systems are reported, as well as a number of dead column measurements. It was observed that lysozyme and mAb interacted specifically with Toyopearl AF-Formyl dead columns depending upon pH and [NaCl], invalidating their dead volume usage. Toyopearl AF-Amino packed dead columns showed no such problems and acted as suitable dead columns without any solution condition dependency. Dead volume determinations using dextran MW standards with protein immobilised SIC columns provided dead volume estimates close to those obtained using Toyopearl AF-Amino dead columns. It is concluded that specific interactions between proteins, including mAbs, and select SIC support phases can compromise the use of some standard approaches for estimating the dead volume of SIC columns. Two other methods were shown to provide good estimates for the dead volume.
Effect of degassing temperature on specific surface area and pore volume measurements of biochar
NASA Astrophysics Data System (ADS)
Sigmund, Gabriel; Hüffer, Thorsten; Kah, Melanie; Hofmann, Thilo
2017-04-01
Specific surface area, pore volume, and pore size distribution are key biochar properties that have been related to water and nutrient cycling, microbial activity as well as sorption potential for organic compounds. Specific surface area and pore volume are commonly determined by measurement of physisorption of N2 and/or CO2. The measurement requires prior degassing of the samples, which may change the structure of the materials. Information on degassing temperature is rarely reported in literature, and recommendations differ considerably between existing guidelines for biochar characterization. Therefore, the influence of degassing temperature on N2 and CO2physisorption measurements was investigated by systematically degassing a range of materials, including four biochars, Al2O3 and carbon nanotubes at different temperatures (105 ˚ C, 150 ˚ C, 200 ˚ C, 250 ˚ C and 300 ˚ C for ≥ 14 h each). Measured specific surface area and pore volume increased with increasing degassing temperature for all biochars. Additional surface area and pore volume may have become available as components in biochars volatilized during the degassing phase. The results of our study showed that (i) degassing conditions change material properties, and influence physisorption measurements for biochar (ii) comparison between parameters derived from different degassing protocols may not be appropriate, and (iii) degassing protocols should be harmonized in the biochar community [1]. [1] Sigmund, et al. (2016), "Biochar total surface area and total pore volume determined by N2 and CO2 physisorption are strongly influenced by degassing temperature", STOTEN, doi: http://dx.doi.org/10.1016/j.scitotenv.2016.12.023.
Khalil, A H
1998-01-01
Physical and sensory characteristics of cakes prepared with either the carbohydrate-based fat replacers N-Flate, Paselli MD 10 and Litesse (0, 25, 50 and 75% of fat weight) or fat replacers plus emulsifier (mono- and diglycerides; 0 and 3% of flour weight) were studied. Specific gravity of the batter was significantly (p < or = 0.05) improved by using the carbohydrate-based fat replacers, especially at the 25 and 50% replacement levels. The combination of the emulsifier with either Paselli MD 10 or Litesse also enhanced the specific gravity. Cakes prepared with fat replacers at the 25 and 50% levels had higher volumes, specific volume and standing heights than those of the control. Cakes prepared with fat replacers at the 25, 50 and 75% levels were more compressible than the control. Cakes prepared with Paselli MD 10 had the highest volumes, specific volume, standing heights and compressibilities. Incorporation of emulsifier with fat replacers improved cake volumes, standing heights and compressibilities. Cakes prepared with fat replacers exhibited higher crust and crumb color values compared to the control. Cakes prepared with 25 or 50% fat replacers had higher mean scores for flavor, softness and eating quality than the control. Incorporation of emulsifier with fat replacers did not affect the crust color, crumb color and flavor, but significantly (p < or = 0.05) improved softness and eating quality.
Improving adsorption cryocoolers by multi-stage compression and reducing void volume
NASA Technical Reports Server (NTRS)
Bard, S.
1986-01-01
It is shown that the performance of gas adsorption cryocoolers is greatly improved by using adsorbents with low void volume within and between individual adsorbent particles (reducing void volumes in plumbing lines), and by compressing the working fluid in more than one stage. Refrigerator specific power requirements and compressor volumetric efficiencies are obtained in terms of adsorbent and plumbing line void volumes and operating pressures for various charcoal adsorbents using an analytical model. Performance optimization curves for 117.5 and 80 K charcoal/nitrogen adsorption cryocoolers are given for both single stage and multistage compressor systems, and compressing the nitrogen in two stages is shown to lower the specific power requirements by 18 percent for the 117.5 K system.
Detection of low-volume blood loss: compensatory reserve versus traditional vital signs.
Stewart, Camille L; Mulligan, Jane; Grudic, Greg Z; Convertino, Victor A; Moulton, Steven L
2014-12-01
Humans are able to compensate for low-volume blood loss with minimal change in traditional vital signs. We hypothesized that a novel algorithm, which analyzes photoplethysmogram (PPG) wave forms to continuously estimate compensatory reserve would provide greater sensitivity and specificity to detect low-volume blood loss compared with traditional vital signs. The compensatory reserve index (CRI) is a measure of the reserve remaining to compensate for reduced central blood volume, where a CRI of 1 represents supine normovolemia and 0 represents the circulating blood volume at which hemodynamic decompensation occurs; values between 1 and 0 indicate the proportion of reserve remaining. Subjects underwent voluntary donation of 1 U (approximately 450 mL) of blood. Demographic and continuous noninvasive vital sign wave form data were collected, including PPG, heart rate, systolic blood pressure, cardiac output, and stroke volume. PPG wave forms were later processed by the algorithm to estimate CRI values. Data were collected from 244 healthy subjects (79 males and 165 females), with a mean (SD) age of 40.1 (14.2) years and mean (SD) body mass index of 25.6 (4.7). After blood donation, CRI significantly decreased in 92% (α = 0.05; 95% confidence interval [CI], 88-95%) of the subjects. With the use of a threshold decrease in CRI of 0.05 or greater for the detection of 1 U of blood loss, the receiver operating characteristic area under the curve was 0.90, with a sensitivity of 0.84 and specificity of 0.86. In comparison, systolic blood pressure (52%; 95% CI, 45-59%), heart rate (65%; 95% CI, 58-72%), cardiac output (47%; 95% CI, 40-54%), and stroke volume (74%; 95% CI, 67-80%) changed in fewer subjects, had significantly lower receiver operating characteristic area under the curve values, and significantly lower specificities for detecting the same volume of blood loss. Consistent with our hypothesis, CRI detected low-volume blood loss with significantly greater specificity than other traditional physiologic measures. These findings warrant further evaluation of the CRI algorithm in actual trauma settings. Diagnostic study, level II.
Frequency of medical malpractice claims: The effects of volumes and specialties.
Buzzacchi, Luigi; Scellato, Giuseppe; Ughetto, Elisa
2016-12-01
A medical malpractice occurs when a physician or healthcare personnel, because of lack of skill or negligence, causes injury to a patient, who can decide to claim for the damages suffered by suing the facility and/or healthcare personnel. In this paper we analyze the frequency of medical malpractice insurance claims in an Italian region, in order to estimate the presence of significant trends and to identify volume effects at both department and healthcare organization levels. We rely on a unique dataset reporting the universe of 2144 injuries caused by medical or surgical errors that resulted in a request to the insurer for coverage over the years 2004-2010 in ten public healthcare organizations. Results show the presence of positive volume effects, as the number of malpractice claims grows less than proportionally with respect to department volumes. Volume effects are particularly relevant for orthopedics and general surgery. We also find the presence of significant positive volume effects at the level of healthcare organizations. Finally, the joint observation of the results on the frequency of malpractice claims and on the time lag between the occurrence of the malpractice event and the filing of the related claim, suggests that the number of malpractice claims has increased over time. Results indicate that organizational and managerial actions concerning the increase in volumes of specific departments or health organizations are context specific and must be specifically tailored. Copyright © 2016 Elsevier Ltd. All rights reserved.
Simulated pressure denaturation thermodynamics of ubiquitin.
Ploetz, Elizabeth A; Smith, Paul E
2017-12-01
Simulations of protein thermodynamics are generally difficult to perform and provide limited information. It is desirable to increase the degree of detail provided by simulation and thereby the potential insight into the thermodynamic properties of proteins. In this study, we outline how to analyze simulation trajectories to decompose conformation-specific, parameter free, thermodynamically defined protein volumes into residue-based contributions. The total volumes are obtained using established methods from Fluctuation Solution Theory, while the volume decomposition is new and is performed using a simple proximity method. Native and fully extended ubiquitin are used as the test conformations. Changes in the protein volumes are then followed as a function of pressure, allowing for conformation-specific protein compressibility values to also be obtained. Residue volume and compressibility values indicate significant contributions to protein denaturation thermodynamics from nonpolar and coil residues, together with a general negative compressibility exhibited by acidic residues. Copyright © 2017 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Educational Media Council, Inc., New York, NY.
THIS 14-VOLUME SERIES INCLUDES TITLES AND DESCRIPTIONS FOR ALL CURRENT AND GENERALLY AVAILABLE EDUCATIONAL MEDIA, EXCLUDING STANDARD PRINT MATERIALS. EACH VOLUME COVERS A SPECIFIC SUBJECT AREA, LISTS TITLES ALPHABETICALLY AND BY SUBJECT, DESCRIBES EACH ENTRY, AND LISTS NAMES AND ADDRESSES OF SOURCES FOR THE MATERIALS. VOLUME 14 IS A CUMULATIVE…
Scan-based volume animation driven by locally adaptive articulated registrations.
Rhee, Taehyun; Lewis, J P; Neumann, Ulrich; Nayak, Krishna S
2011-03-01
This paper describes a complete system to create anatomically accurate example-based volume deformation and animation of articulated body regions, starting from multiple in vivo volume scans of a specific individual. In order to solve the correspondence problem across volume scans, a template volume is registered to each sample. The wide range of pose variations is first approximated by volume blend deformation (VBD), providing proper initialization of the articulated subject in different poses. A novel registration method is presented to efficiently reduce the computation cost while avoiding strong local minima inherent in complex articulated body volume registration. The algorithm highly constrains the degrees of freedom and search space involved in the nonlinear optimization, using hierarchical volume structures and locally constrained deformation based on the biharmonic clamped spline. Our registration step establishes a correspondence across scans, allowing a data-driven deformation approach in the volume domain. The results provide an occlusion-free person-specific 3D human body model, asymptotically accurate inner tissue deformations, and realistic volume animation of articulated movements driven by standard joint control estimated from the actual skeleton. Our approach also addresses the practical issues arising in using scans from living subjects. The robustness of our algorithms is tested by their applications on the hand, probably the most complex articulated region in the body, and the knee, a frequent subject area for medical imaging due to injuries. © 2011 IEEE
California State Library: Processing Center Design and Specifications. Volume III, Coding Manual.
ERIC Educational Resources Information Center
Sherman, Don; Shoffner, Ralph M.
As part of the report on the California State Library Processing Center design and specifications, this volume is a coding manual for the conversion of catalog card data to a machine-readable form. The form is compatible with the national MARC system, while at the same time it contains provisions for problems peculiar to the local situation. This…
Bregant, Tina; Rados, Milan; Vasung, Lana; Derganc, Metka; Evans, Alan C; Neubauer, David; Kostovic, Ivica
2013-11-01
A severe form of perinatal hypoxic-ischaemic encephalopathy (HIE) carries a high risk of perinatal death and severe neurological sequelae while in mild HIE only discrete cognitive disorders may occur. To compare total brain volumes and region-specific cortical measurements between young adults with mild-moderate perinatal HIE and a healthy control group of the same age. MR imaging was performed in a cohort of 14 young adults (9 males, 5 females) with a history of mild or moderate perinatal HIE. The control group consisted of healthy participants, matched with HIE group by age and gender. Volumetric analysis was done after the processing of MR images using a fully automated CIVET pipeline. We measured gyrification indexes, total brain volume, volume of grey and white matter, and of cerebrospinal fluid. We also measured volume, thickness and area of the cerebral cortex in the parietal, occipital, frontal, and temporal lobe, and of the isthmus cinguli, parahippocampal and cingulated gyrus, and insula. The HIE patient group showed smaller absolute volumetric data. Statistically significant (p < 0.05) reductions of gyrification index in the right hemisphere, of cortical areas in the right temporal lobe and parahippocampal gyrus, of cortical volumes in the right temporal lobe and of cortical thickness in the right isthmus of the cingulate gyrus were found. Comparison between the healthy group and the HIE group of the same gender showed statistically significant changes in the male HIE patients, where a significant reduction was found in whole brain volume; left parietal, bilateral temporal, and right parahippocampal gyrus cortical areas; and bilateral temporal lobe cortical volume. Our analysis of total brain volumes and region-specific corticometric parameters suggests that mild-moderate forms of perinatal HIE lead to reductions in whole brain volumes. In the study reductions were most pronounced in temporal lobe and parahippocampal gyrus. Copyright © 2013 European Paediatric Neurology Society. All rights reserved.
Highway Safety Program Manual: Volume 2: Motor Vehicle Registration.
ERIC Educational Resources Information Center
National Highway Traffic Safety Administration (DOT), Washington, DC.
Volume 2 of the 19-volume Highway Safety Program Manual (which provides guidance to State and local governments on preferred highway safety practices) describes the purposes and specific objectives of motor vehicle registration. Federal authority for vehicle registration and general policies regarding vehicle registration systems are outlined.…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gloudemans, J.R.
1991-08-01
The multiloop integral system test (MIST) was part of a multiphase program started in 1983 to address small-break loss-of-coolant accidents (SBLOCAs) specific to Babcock Wilcox-designed plants. MIST was sponsored by the US Nuclear Regulatory Commission, the Babcock Wilcox Owners Group, the Electric Power Research Institute, and Babcock Wilcox. The unique features of the Babcock Wilcox design, specifically the hot leg U-bends and steam generators, prevented the use of existing integral system data or existing integral system facilities to addresss the thermal-hydraulic SBLOCA questions. MIST was specifically designed and constructed for this program, and an existing facility -- the once-through integralmore » system (OTIS) -- was also used. Data from MIST and OTIS are used to benchmark the adequacy of system codes, such as RELAP5 and TRAC, for predicting abnormal plant transients. The MIST program is reported in eleven volumes; Volumes 2 through 8 pertain to groups of Phase 3 tests by type, Volume 9 presents inter-group comparisons. Volume 10 provides comparisons between the RELAP5 MOD2 calculations and MIST observations, and Volume 11 (with addendum) presents the later, Phase 4 tests. This is Volume 1 of the MIST final report, a summary of the entire MIST program. Major topics include: test advisory grop (TAG) issues; facility scaling and design; test matrix; observations; comparisons of RELAP5 calculations to MIST observations; and MIST versus the TAG issues. 11 refs., 29 figs., 9 tabs.« less
Specific storage volumes: A useful tool for CO2 storage capacity assessment
Brennan, S.T.; Burruss, R.C.
2006-01-01
Subsurface geologic strata have the potential to store billions of tons of anthropogenic CO2; therefore, geologic carbon sequestration can be an effective mitigation tool used to slow the rate at which levels of atmospheric CO2 are increasing. Oil and gas reservoirs, coal beds, and saline reservoirs can be used for CO2 storage; however, it is difficult to assess and compare the relative storage capacities of these different settings. Typically, CO2 emissions are reported in units of mass, which are not directly applicable to comparing the CO2 storage capacities of the various storage targets. However, if the emission values are recalculated to volumes per unit mass (specific volume) then the volumes of geologic reservoirs necessary to store CO2 emissions from large point sources can be estimated. The factors necessary to convert the mass of CO2 emissions to geologic storage volume (referred to here as Specific Storage Volume or 'SSV') can be reported in units of cubic meters, cubic feet, and petroleum barrels. The SSVs can be used to estimate the reservoir volume needed to store CO2 produced over the lifetime of an individual point source, and to identify CO2 storage targets of sufficient size to meet the demand from that given point source. These storage volumes also can then be projected onto the land surface to outline a representative "footprint," which marks the areal extent of storage. This footprint can be compared with the terrestrial carbon sequestration capacity of the same land area. The overall utility of this application is that the total storage capacity of any given parcel of land (from surface to basement) can be determined, and may assist in making land management decisions. ?? Springer Science+Business Media, LLC 2006.
NASA Technical Reports Server (NTRS)
Benepe, D. B.; Cunningham, A. M., Jr.; Dunmyer, W. D.
1978-01-01
Volume 2 of this three volume report is presented. This volume presents plotted variations of power spectral density data with frequency for each structural response item for each data sampled and analyzed during the course of the investigation. Some of the information contained in Volume 1 are repeated to allow the reader to identify the specific conditions appropriate to each plot presented and to interpret the data.
NASA Technical Reports Server (NTRS)
1974-01-01
All general purpose equipment items contained in the final carry-on laboratory (COL) design concepts are described in terms of specific requirements identified for COL use, hardware status, and technical parameters such as weight, volume, power, range, and precision. Estimated costs for each item are given, along with projected development times.
Surgeon specialization and operative mortality in United States: retrospective analysis.
Sahni, Nikhil R; Dalton, Maurice; Cutler, David M; Birkmeyer, John D; Chandra, Amitabh
2016-07-21
To measure the association between a surgeon's degree of specialization in a specific procedure and patient mortality. Retrospective analysis of Medicare data. US patients aged 66 or older enrolled in traditional fee for service Medicare. 25 152 US surgeons who performed one of eight procedures (carotid endarterectomy, coronary artery bypass grafting, valve replacement, abdominal aortic aneurysm repair, lung resection, cystectomy, pancreatic resection, or esophagectomy) on 695 987 patients in 2008-13. Relative risk reduction in risk adjusted and volume adjusted 30 day operative mortality between surgeons in the bottom quarter and top quarter of surgeon specialization (defined as the number of times the surgeon performed the specific procedure divided by his/her total operative volume across all procedures). For all four cardiovascular procedures and two out of four cancer resections, a surgeon's degree of specialization was a significant predictor of operative mortality independent of the number of times he or she performed that procedure: carotid endarterectomy (relative risk reduction between bottom and top quarter of surgeons 28%, 95% confidence interval 0% to 48%); coronary artery bypass grafting (15%, 4% to 25%); valve replacement (46%, 37% to 53%); abdominal aortic aneurysm repair (42%, 29% to 53%); lung resection (28%, 5% to 46%); and cystectomy (41%, 8% to 63%). In five procedures (carotid endarterectomy, valve replacement, lung resection, cystectomy, and esophagectomy), the relative risk reduction from surgeon specialization was greater than that from surgeon volume for that specific procedure. Furthermore, surgeon specialization accounted for 9% (coronary artery bypass grafting) to 100% (cystectomy) of the relative risk reduction otherwise attributable to volume in that specific procedure. For several common procedures, surgeon specialization was an important predictor of operative mortality independent of volume in that specific procedure. When selecting a surgeon, patients, referring physicians, and administrators assigning operative workload may want to consider a surgeon's procedure specific volume as well as the degree to which a surgeon specializes in that procedure. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Bex, T; Iannaccone, F; Stautemas, J; Baguet, A; De Beule, M; Verhegghe, B; Aerts, P; De Clercq, D; Derave, W
2017-03-01
Excellence in either sprinting or endurance running requires specific musculo-skeletal characteristics of the legs. This study aims to investigate the morphology of the leg of sprinters and endurance runners of Caucasian ethnicity. Eight male sprinters and 11 male endurance runners volunteered to participate in this cross-sectional study. They underwent magnetic resonance imaging and after data collection, digital reconstruction was done to calculate muscle volumes and bone lengths. Sprinters have a higher total upper leg volume compared to endurance runners (7340 vs 6265 cm 3 ). Specifically, the rectus femoris, vastus lateralis, and hamstrings showed significantly higher muscle volumes in the sprint group. For the lower leg, only a higher muscle volume was found in the gastrocnemius lateralis for the sprinters. No differences were found in muscle volume distribution, center of mass in the different muscles, or relative bone lengths. There was a significant positive correlation between ratio hamstrings/quadriceps volume and best running performance in the sprint group. Sprinters and endurance runners of Caucasian ethnicity showed the greatest distinctions in muscle volumes, rather than in muscle distributions or skeletal measures. Sprinters show higher volumes in mainly the proximal and lateral leg muscles than endurance runners. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Verbal and non-verbal memory and hippocampal volumes in a memory clinic population.
Bonner-Jackson, Aaron; Mahmoud, Shamseldeen; Miller, Justin; Banks, Sarah J
2015-10-15
Better characterization of the relationship between episodic memory and hippocampal volumes is crucial in early detection of neurodegenerative disease. We examined these relationships in a memory clinic population. Participants (n = 226) underwent structural magnetic resonance imaging and tests of verbal (Hopkins Verbal Learning Test-Revised, HVLT-R) and non-verbal (Brief Visuospatial Memory Test-Revised, BVMT-R) memory. Correlational analyses were performed, and analyses on clinical subgroups (i.e., amnestic Mild Cognitive Impairment, non-amnestic Mild Cognitive Impairment, probable Alzheimer's disease, intact memory) were conducted. Positive associations were identified between bilateral hippocampal volumes and both memory measures, and BVMT-R learning slope was more strongly positively associated with hippocampal volumes than HVLT-R learning slope. Amnestic Mild Cognitive Impairment (aMCI) participants showed specific positive associations between BVMT-R performance and hippocampal volumes bilaterally. Additionally, analyses of the aMCI group showed trend-level evidence of material-specific lateralization, such that retention of verbal information was positively associated with left hippocampal volume, whereas learning curve and retention of non-verbal information was positively associated with right hippocampal volume. Findings support the link between episodic memory and hippocampal volumes in a memory clinic population. Non-verbal memory measures also may have higher diagnostic value, particularly in individuals at elevated risk for Alzheimer's disease.
3D tumor measurement in cone-beam CT breast imaging
NASA Astrophysics Data System (ADS)
Chen, Zikuan; Ning, Ruola
2004-05-01
Cone-beam CT breast imaging provides a digital volume representation of a breast. With a digital breast volume, the immediate task is to extract the breast tissue information, especially for suspicious tumors, preferably in an automatic manner or with minimal user interaction. This paper reports a program for three-dimensional breast tissue analysis. It consists of volumetric segmentation (by globally thresholding), subsegmentation (connection-based separation), and volumetric component measurement (volume, surface, shape, and other geometrical specifications). A combination scheme of multi-thresholding and binary volume morphology is proposed to fast determine the surface gradients, which may be interpreted as the surface evolution (outward growth or inward shrinkage) for a tumor volume. This scheme is also used to optimize the volumetric segmentation. With a binary volume, we decompose the foreground into components according to spatial connectedness. Since this decomposition procedure is performed after volumetric segmentation, it is called subsegmentation. The subsegmentation brings the convenience for component visualization and measurement, in the whole support space, without interference from others. Upon the tumor component identification, we measure the following specifications: volume, surface area, roundness, elongation, aspect, star-shapedness, and location (centroid). A 3D morphological operation is used to extract the cluster shell and, by delineating the corresponding volume from the grayscale volume, to measure the shell stiffness. This 3D tissue measurement is demonstrated with a tumor-borne breast specimen (a surgical part).
Left atrial volume and function in dogs with naturally occurring myxomatous mitral valve disease.
Höllmer, M; Willesen, J L; Tolver, A; Koch, J
2017-02-01
Myxomatous mitral valve disease (MMVD) induces progressive left atrial (LA) enlargement. The LA modulates left ventricular filling and performance through its reservoir, conduit, and contractile function. Assessment of LA size and function may provide valuable information on the level of cardiac compensation. Left atrial function in dogs with naturally occurring MMVD remains largely unexplored. The objective of this study was to evaluate LA volume and function in dogs with naturally occurring MMVD. This prospective study included 205 client-owned dogs of different breeds, 114 healthy dogs, and 91 dogs with MMVD of different disease severities. Using two-dimensional echocardiography, the biplane area-length method was applied to assess LA volume and calculate volumetric indices of LA reservoir, conduit, and contractile function. Left atrial volume and LA stroke volume increased, whereas LA reservoir and contractile function decreased with increasing disease severity. A maximal LA volume <2.25mL/kg was the optimal cut off identified for excluding congestive heart failure in dogs with chronic MMVD with a sensitivity of 96% and a specificity of 100%. An active LA emptying fraction <24% and/or a LA expansion index <126% were suggestive of congestive heart failure in dogs with chronic MMVD with a sensitivity of 77% and a specificity of 89% and a sensitivity of 82% and a specificity of 82%, respectively. Dogs with MMVD appear to have larger LA volumes with poorer LA function. Deteriorating LA function, characterized by a decreasing reservoir and active contractile function, was evident in dogs with MMVD with increasing disease severity. Copyright © 2016 Elsevier B.V. All rights reserved.
Batalla, Albert; Lorenzetti, Valentina; Chye, Yann; Yücel, Murat; Soriano-Mas, Carles; Bhattacharyya, Sagnik; Torrens, Marta; Crippa, José A.S.; Martín-Santos, Rocío
2018-01-01
Abstract Introduction: Hippocampal neuroanatomy is affected by genetic variations in dopaminergic candidate genes and environmental insults, such as early onset of chronic cannabis exposure. Here, we examine how hippocampal total and subregional volumes are affected by cannabis use and functional polymorphisms of dopamine-relevant genes, including the catechol-O-methyltransferase (COMT), dopamine transporter (DAT1), and the brain-derived neurotrophic factor (BDNF) genes. Material and Methods: We manually traced total hippocampal volumes and automatically segmented hippocampal subregions using high-resolution MRI images, and performed COMT, DAT1, and BDNF genotyping in 59 male Caucasian young adults aged 18–30 years. These included 30 chronic cannabis users with early-onset (regular use at <16 years) and 29 age-, education-, and intelligence-matched controls. Results: Cannabis use and dopaminergic gene polymorphism had both distinct and interactive effects on the hippocampus. We found emerging alterations of hippocampal total and specific subregional volumes in cannabis users relative to controls (i.e., CA1, CA2/3, and CA4), and associations between cannabis use levels and total and specific subregional volumes. Furthermore, total hippocampal volume and the fissure subregion were affected by cannabis×DAT1 polymorphism (i.e., 9/9R and in 10/10R alleles), reflecting high and low levels of dopamine availability. Conclusion: These findings suggest that cannabis exposure alters the normal relationship between DAT1 polymorphism and the anatomy of total and subregional hippocampal volumes, and that specific hippocampal subregions may be particularly affected. PMID:29404409
Batalla, Albert; Lorenzetti, Valentina; Chye, Yann; Yücel, Murat; Soriano-Mas, Carles; Bhattacharyya, Sagnik; Torrens, Marta; Crippa, José A S; Martín-Santos, Rocío
2018-01-01
Introduction: Hippocampal neuroanatomy is affected by genetic variations in dopaminergic candidate genes and environmental insults, such as early onset of chronic cannabis exposure. Here, we examine how hippocampal total and subregional volumes are affected by cannabis use and functional polymorphisms of dopamine-relevant genes, including the catechol-O-methyltransferase (COMT), dopamine transporter (DAT1), and the brain-derived neurotrophic factor (BDNF) genes. Material and Methods: We manually traced total hippocampal volumes and automatically segmented hippocampal subregions using high-resolution MRI images, and performed COMT, DAT1, and BDNF genotyping in 59 male Caucasian young adults aged 18-30 years. These included 30 chronic cannabis users with early-onset (regular use at <16 years) and 29 age-, education-, and intelligence-matched controls. Results: Cannabis use and dopaminergic gene polymorphism had both distinct and interactive effects on the hippocampus. We found emerging alterations of hippocampal total and specific subregional volumes in cannabis users relative to controls (i.e., CA1, CA2/3, and CA4), and associations between cannabis use levels and total and specific subregional volumes. Furthermore, total hippocampal volume and the fissure subregion were affected by cannabis×DAT1 polymorphism (i.e., 9/9R and in 10/10R alleles), reflecting high and low levels of dopamine availability. Conclusion: These findings suggest that cannabis exposure alters the normal relationship between DAT1 polymorphism and the anatomy of total and subregional hippocampal volumes, and that specific hippocampal subregions may be particularly affected.
Highway Safety Program Manual: Volume 12: Highway Design, Construction and Maintenance.
ERIC Educational Resources Information Center
National Highway Traffic Safety Administration (DOT), Washington, DC.
Volume 12 of the 19-volume Highway Safety Program Manual (which provides guidance to State and local governments on preferred highway safety practices) focuses on highway design, construction and maintenance. The purpose and specific objectives of such a program are described. Federal authority in the area of highway safety and policies regarding…
Advances in Education Research, Winter 1999.
ERIC Educational Resources Information Center
Advances in Education Research, 1999
1999-01-01
This volume presents selected articles related to the impact of early intervention programs. This is part of a two volume set designed to showcase some of the best cutting edge research in these programs. This volume focuses specifically on aspects of the programs that have proven to be most successful in helping students and meeting programmatic…
Highway Safety Program Manual: Volume 6: Codes and Laws.
ERIC Educational Resources Information Center
National Highway Traffic Safety Administration (DOT), Washington, DC.
Volume 6 of the 19-volume Highway Safety Program Manual (which provides guidance to State and local governments on preferred safety practices) concentrates on codes and laws. The purpose and specific objectives of the Codes and Laws Program, Federal authority in the area of highway safety, and policies regarding traffic regulation are described.…
Highway Safety Program Manual: Volume 3: Motorcycle Safety.
ERIC Educational Resources Information Center
National Highway Traffic Safety Administration (DOT), Washington, DC.
Volume 3 of the 19-volume Highway Safety Program Manual (which provides guidance to State and local governments on preferred highway safety practices) concentrates on aspects of motorcycle safety. The purpose and specific objectives of a State motorcycle safety program are outlined. Federal authority in the highway safety area and general policies…
Highway Safety Program Manual: Volume 9: Identification and Surveillance of Accident Locations.
ERIC Educational Resources Information Center
National Highway Traffic Safety Administration (DOT), Washington, DC.
Volume 9 of the 19-volume Highway Safety Program Manual (which provides guidance to State and local governments on preferred highway safety practices) focuses on identification and surveillance of accident locations. The purpose of the program, its specific objectives, and its relationship with other programs are explored. Federal authority in the…
Wisconsin Elementary Teacher Education Project. Volumes I-IV.
ERIC Educational Resources Information Center
Kean, John M., Ed.
This four-volume report includes position papers and specifications for the elementary teacher education program of the University of Wisconsin in the year 1975 and beyond. Volume 1 includes a series of 12 position papers which cover topics ranging from teacher roles and systems approaches to instruction to control and management procedures for…
2007-04-26
Marc Gietter (#4929) Fuel reduction solutions for deployment of mobile electric power systems - Oerlikon Contraves , Philippe Bisaillon Eng. MEM...9,675 Whr/kg Global Commodity 8 e50 • 50 Watt Continuous Power • 12V • 100 Watt peak power • System Specifications • Dry system weight , less than 2.25...System Dry Weight 2.25kg Volume 4.5 Net System Efficiency 17% Specifications Specific Energy 3 Day Mission W-hr/kg 775 10 Day Mission W-hr/kg 1200 Goal
Chlorophyll-a specific volume scattering function of phytoplankton.
Tan, Hiroyuki; Oishi, Tomohiko; Tanaka, Akihiko; Doerffer, Roland; Tan, Yasuhiro
2017-06-12
Chlorophyll-a specific light volume scattering functions (VSFs) by cultured phytoplankton in visible spectrum range is presented. Chlorophyll-a specific VSFs were determined based on the linear least squares method using a measured VSFs with different chlorophyll-a concentrations. We found obvious variability of it in terms of spectral and angular shapes of VSF between cultures. It was also presented that chlorophyll-a specific scattering significantly affected on spectral variation of the remote sensing reflectance, depending on spectral shape of b. This result is useful for developing an advance algorithm of ocean color remote sensing and for deep understanding of light in the sea.
NASA Technical Reports Server (NTRS)
Green, F. M.; Resnick, D. R.
1979-01-01
An FMP (Flow Model Processor) was designed for use in the Numerical Aerodynamic Simulation Facility (NASF). The NASF was developed to simulate fluid flow over three-dimensional bodies in wind tunnel environments and in free space. The facility is applicable to studying aerodynamic and aircraft body designs. The following general topics are discussed in this volume: (1) FMP functional computer specifications; (2) FMP instruction specification; (3) standard product system components; (4) loosely coupled network (LCN) specifications/description; and (5) three appendices: performance of trunk allocation contention elimination (trace) method, LCN channel protocol and proposed LCN unified second level protocol.
Kalfa, David; Chai, Paul; Bacha, Emile
2014-08-01
A significant inverse relationship of surgical institutional and surgeon volumes to outcome has been demonstrated in many high-stakes surgical specialties. By and large, the same results were found in pediatric cardiac surgery, for which a more thorough analysis has shown that this relationship depends on case complexity and type of surgical procedures. Lower-volume programs tend to underperform larger-volume programs as case complexity increases. High-volume pediatric cardiac surgeons also tend to have better results than low-volume surgeons, especially at the more complex end of the surgery spectrum (e.g., the Norwood procedure). Nevertheless, this trend for lower mortality rates at larger centers is not universal. All larger programs do not perform better than all smaller programs. Moreover, surgical volume seems to account for only a small proportion of the overall between-center variation in outcome. Intraoperative technical performance is one of the most important parts, if not the most important part, of the therapeutic process and a critical component of postoperative outcome. Thus, the use of center-specific, risk-adjusted outcome as a tool for quality assessment together with monitoring of technical performance using a specific score may be more reliable than relying on volume alone. However, the relationship between surgical volume and outcome in pediatric cardiac surgery is strong enough that it ought to support adapted and well-balanced health care strategies that take advantage of the positive influence that higher center and surgeon volumes have on outcome.
Chye, Yann; Solowij, Nadia; Suo, Chao; Batalla, Albert; Cousijn, Janna; Goudriaan, Anna E; Martin-Santos, Rocio; Whittle, Sarah; Lorenzetti, Valentina; Yücel, Murat
2017-07-01
Cannabis (CB) use and dependence are associated with regionally specific alterations to brain circuitry and substantial psychosocial impairment. The objective of this study was to investigate the association between CB use and dependence, and the volumes of brain regions critically involved in goal-directed learning and behaviour-the orbitofrontal cortex (OFC) and caudate. In the largest multi-site structural imaging study of CB users vs healthy controls (HC), 140 CB users and 121 HC were recruited from four research sites. Group differences in OFC and caudate volumes were investigated between HC and CB users and between 70 dependent (CB-dep) and 50 non-dependent (CB-nondep) users. The relationship between quantity of CB use and age of onset of use and caudate and OFC volumes was explored. CB users (consisting of CB-dep and CB-nondep) did not significantly differ from HC in OFC or caudate volume. CB-dep compared to CB-nondep users exhibited significantly smaller volume in the medial and the lateral OFC. Lateral OFC volume was particularly smaller in CB-dep females, and reduced volume in the CB-dep group was associated with higher monthly cannabis dosage. Smaller medial OFC volume may be driven by CB dependence-related mechanisms, while smaller lateral OFC volume may be due to ongoing exposure to cannabinoid compounds. The results highlight a distinction between cannabis use and dependence and warrant examination of gender-specific effects in studies of CB dependence.
Production and delivery of a fluid mixture to an annular volume of a wellbore
Hermes, Robert E [Los Alamos, NM; Bland, Ronald Gene [Houston, TX; Foley, Ron Lee [Magnolia, TX; Bloys, James B [Katy, TX; Gonzalez, Manuel E [Kingwood, NM; Daniel, John M [Germantown, TN; Robinson, Ian M [Guisborough, GB; Carpenter, Robert B [Tomball, TX
2012-01-24
The methods described herein generally relate to preparing and delivering a fluid mixture to a confined volume, specifically an annular volume located between two concentrically oriented casing strings within a hydrocarbon fluid producing well. The fluid mixtures disclosed herein are useful in controlling pressure in localized volumes. The fluid mixtures comprise at least one polymerizable monomer and at least one inhibitor. The processes and methods disclosed herein allow the fluid mixture to be stored, shipped and/or injected into localized volumes, for example, an annular volume defined by concentric well casing strings.
Smith, A M J; Bonato, M; Dzama, K; Malecki, I A; Cloete, S W P
2018-06-01
Successful assisted reproduction techniques, with specific focus on in vitro semen storage for artificial insemination, are dependent on certain key elements which includes the biochemical profiling of semen. The objective of this study was to complete an ostrich seminal plasma (SP) evaluation by inductively coupled plasma mass spectrometry (ICP-MS) among seven males at different daily intervals (day 1, 3, 7, 11, 15, 19, 21, 23, 25, 26, 27, 28) for a period of 28 days during spring (August to September) for mineral profiling. The effect of collection day and male on sperm concentration, semen volume and seminal plasma volume, was explored as well as the relationships amongst these specific sperm traits and SP minerals. Variation amongst SP mineral concentrations, accounted for by the fixed effects of sperm concentration, semen volume, seminal plasma volume, collection day and male, ranged from 18% to 77%. Male had the largest effect on variation in SP minerals, namely: phosphorus (P), potassium (K), calcium (Ca), sodium (Na), boron (B), iron (Fe), cobalt (Co), nickel (Ni), copper (Cu), molybdenum (Mo), barium (Ba), arsenic (As) and selenium (Se). Sperm concentration instigated fluctuations of P, magnesium (Mg), B, zinc (Zn), Fe, aluminium (Al), Se, manganese (Mn) and lead (Pb). Semen volume had an effect on Na, K, B, Pb and Ba while seminal plasma volume only influenced variation in Na. There were fluctuations among collection days of specific micro minerals, Ni and Mo, with initial Ni concentrations being relatively greater and Mo at lesser concentrations. Semen volume, seminal plasma volume and sperm concentration varied amongst males. Sperm concentrations during the initial collection days, 1 and 3, were less than that for days 7 to 28. Significant variation of SP minerals and sperm characteristics among ejaculates and males suggest an association of these specific elements with sperm function and are, therefore, considered to be of potential importance to success of assisted reproduction technology for the ostrich. The relationship amongst sperm concentration and collection day confirms the need to conduct an initial period of collection to stabilise a greater sperm concentration to optimise sperm numbers for artificial insemination purposes. Copyright © 2018 Elsevier B.V. All rights reserved.
Flood type specific construction of synthetic design hydrographs
NASA Astrophysics Data System (ADS)
Brunner, Manuela I.; Viviroli, Daniel; Sikorska, Anna E.; Vannier, Olivier; Favre, Anne-Catherine; Seibert, Jan
2017-02-01
Accurate estimates of flood peaks, corresponding volumes, and hydrographs are required to design safe and cost-effective hydraulic structures. In this paper, we propose a statistical approach for the estimation of the design variables peak and volume by constructing synthetic design hydrographs for different flood types such as flash-floods, short-rain floods, long-rain floods, and rain-on-snow floods. Our approach relies on the fitting of probability density functions to observed flood hydrographs of a certain flood type and accounts for the dependence between peak discharge and flood volume. It makes use of the statistical information contained in the data and retains the process information of the flood type. The method was tested based on data from 39 mesoscale catchments in Switzerland and provides catchment specific and flood type specific synthetic design hydrographs for all of these catchments. We demonstrate that flood type specific synthetic design hydrographs are meaningful in flood-risk management when combined with knowledge on the seasonality and the frequency of different flood types.
Individual differences in personality traits reflect structural variance in specific brain regions.
Gardini, Simona; Cloninger, C Robert; Venneri, Annalena
2009-06-30
Personality dimensions such as novelty seeking (NS), harm avoidance (HA), reward dependence (RD) and persistence (PER) are said to be heritable, stable across time and dependent on genetic and neurobiological factors. Recently a better understanding of the relationship between personality traits and brain structures/systems has become possible due to advances in neuroimaging techniques. This Magnetic Resonance Imaging (MRI) study investigated if individual differences in these personality traits reflected structural variance in specific brain regions. A large sample of eighty five young adult participants completed the Three-dimensional Personality Questionnaire (TPQ) and had their brain imaged with MRI. A voxel-based correlation analysis was carried out between individuals' personality trait scores and grey matter volume values extracted from 3D brain scans. NS correlated positively with grey matter volume in frontal and posterior cingulate regions. HA showed a negative correlation with grey matter volume in orbito-frontal, occipital and parietal structures. RD was negatively correlated with grey matter volume in the caudate nucleus and in the rectal frontal gyrus. PER showed a positive correlation with grey matter volume in the precuneus, paracentral lobule and parahippocampal gyrus. These results indicate that individual differences in the main personality dimensions of NS, HA, RD and PER, may reflect structural variance in specific brain areas.
Grey matter volume loss is associated with specific clinical motor signs in Huntington's disease.
Coppen, Emma M; Jacobs, Milou; van den Berg-Huysmans, Annette A; van der Grond, Jeroen; Roos, Raymund A C
2018-01-01
Motor disturbances are clinical hallmarks of Huntington's disease (HD) and involve chorea, dystonia, hypokinesia and visuomotor dysfunction. Investigating the association between specific motor signs and different regional volumes is important to understand the heterogeneity of HD. To investigate the motor phenotype of HD and associations with subcortical and cortical grey matter volume loss. Structural T1-weighted MRI scans of 79 HD patients and 30 healthy controls were used to calculate volumes of seven subcortical structures including the nucleus accumbens, hippocampus, thalamus, caudate nucleus, putamen, pallidum and amygdala. Multiple linear regression analyses, corrected for age, gender, CAG, MRI scan protocol and normalized brain volume, were performed to assess the relationship between subcortical volumes and different motor subdomains (i.e. eye movements, chorea, dystonia, hypokinesia/rigidity and gait/balance). Voxel-based morphometry analysis was used to investigate the relationship between cortical volume changes and motor signs. Subcortical volume loss of the accumbens nucleus, caudate nucleus, putamen, and pallidum were associated with higher chorea scores. No other subcortical region was significantly associated with motor symptoms after correction for multiple comparisons. Voxel-based cortical grey matter volume reductions in occipital regions were related with an increase in eye movement scores. In HD, chorea is mainly associated with subcortical volume loss, while eye movements are more related to cortical volume loss. Both subcortical and cortical degeneration has an impact on motor impairment in HD. This implies that there is a widespread contribution of different brain regions resulting in the clinical motor presentation seen in HD patients. Copyright © 2017 Elsevier Ltd. All rights reserved.
Mechanical properties of kenaf composites using dynamic mechanical analysis
NASA Astrophysics Data System (ADS)
Loveless, Thomas A.
Natural fibers show potential to replace glass fibers in thermoset and thermoplastic composites. Kenaf is a bast-type fiber with high specific strength and great potential to compete with glass fibers. In this research kenaf/epoxy composites were analyzed using Dynamic Mechanical Analysis (DMA). A three-point bend apparatus was used in the DMA testing. The samples were tested at 1 hertz, at a displacement of 10 ?m, and at room temperature. The fiber volume content of the kenaf was varied from 20% - 40% in 5% increments. Ten samples of each fiber volume fraction were manufactured and tested. The flexural storage modulus, the flexural loss modulus, and the loss factor were reported. Generally as the fiber volume fraction of kenaf increased, the flexural storage and flexural loss modulus increased. The loss factor remained relatively constant with increasing fiber volume fraction. Woven and chopped fiberglass/epoxy composites were manufactured and tested to be compared with the kenaf/epoxy composites. Both of the fiberglass/epoxy composites reported higher flexural storage and flexural loss modulus values. The kenaf/epoxy composites reported higher loss factor values. The specific flexural storage and specific flexural loss modulus were calculated for both the fiberglass and kenaf fiber composites. Even though the kenaf composites reported a lower density, the fiberglass composites reported higher specific mechanical properties.
Watson, Kathleen Bachtel; Dai, Shifan; Paul, Prabasaj; Carlson, Susan A; Carroll, Dianna D; Fulton, Janet
2016-11-01
Previous studies have examined participation in specific leisure-time physical activities (PA) among US adults. The purpose of this study was to identify specific activities that contribute substantially to total volume of leisure-time PA in US adults. Proportion of total volume of leisure-time PA moderate-equivalent minutes attributable to 9 specific types of activities was estimated using self-reported data from 21,685 adult participants (≥ 18 years) in the National Health and Nutrition Examination Survey 1999-2006. Overall, walking (28%), sports (22%), and dancing (9%) contributed most to PA volume. Attributable proportion was higher among men than women for sports (30% vs. 11%) and higher among women than men for walking (36% vs. 23%), dancing (16% vs. 4%), and conditioning exercises (10% vs. 5%). The proportion was lower for walking, but higher for sports, among active adults than those insufficiently active and increased with age for walking. Compared with other racial/ethnic groups, the proportion was lower for sports among non-Hispanic white men and for dancing among non-Hispanic white women. Walking, sports, and dance account for the most activity time among US adults overall, yet some demographic variations exist. Strategies for PA promotion should be tailored to differences across population subgroups.
Photon activation-15O decay studies of tumor blood flow.
Ten Haken, R K; Nussbaum, G H; Emami, B; Hughes, W L
1981-01-01
A direct, noninvasive method for measuring absolute values of specific capillary blood flow in living tissue is described. The method is based on the photon activation, in situ, of tissue elements and the measurement of the subsequent decay of the positron activity induced, employing coincidence detection of the photon pairs produced in positron annihilation. Analysis of the time-dependent coincidence spectrum reveals the contribution to the total signal from the decay of 15O, from which the specific capillary blood flow in the imaged, activated volume is ultimately determined. By virtue of its introduction of the radioisotope of interest (15O) directly and uniformly into the tissue volume under investigation, the method described permits both the nonperfused and well perfused fractions of an activated volume to be estimated and hence, the average specific blood flow within imaged tumor volumes to be computed. The model employed to describe and analyze the data is discussed in detail. Results of application of the technique to measurement of specific blood flow in rhabdomyosarcoma tumors grown in WAG/Rij rats are presented and discussed. The method is shown to be reliable and well suited to studies designed to determined the effects of various agents, such as heat, radiation and drugs, on tumor blood flow.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Binkert, Christoph A.; Debatin, Jorg F.; Schneider, Ernst
2001-07-15
Purpose: Predicting therapeutic benefit from percutaneous transluminal renal angioplasty (PTRA) in patients with renal artery stenosis (RAS) remains difficult. This study investigates whether magnetic resonance (MR)-based renal artery flow measurements relative to renal parenchymal volume can predict clinical outcome following PTRA.Methods: The data on 23 patients (13 men, 10 women; age range 47-82 years, mean age 64 years) were analyzed. The indication for treatment was hypertension (n = 18) or renal insufficiency (n = 5). Thirty-four cases of RAS were identified: bilateral disease was manifest in 11 and unilateral disease in 12 patients. The MR imaging protocol included a breath-hold,more » cardiac-gated cine phase-contrast sequence for renal flow measurement and a fast multiplanar spoiled gradient-echo sequence for renal volume measurement. MR measurements were performed on the day prior to and the day following PTRA. Clinical success was defined as (a) a reduction in diastolic blood pressure > 15% or (b) a reduction in serum creatinine > 20%. Kidneys were categorized as normal volume or low volume. A renal flow index (RFI) was calculated by dividing the renal flow (ml/min) by the renal volume (cm{sup 3}).Results: Clinical success was observed in 11 patients. Twelve patients did not benefit from angioplasty. Normal kidney volume was seen in 10 of 11 responders and in 8 of 12 nonresponders, resulting in a sensitivity of 91%, specificity of 33%, a positive predictive value (PPV) of 56% and a negative predictive value (NPV) of 80%. A RFI below a threshold of 1.5 ml/min/cm{sup 3} predicted successful outcome with 100% sensitivity, 33% specificity, 58% PPV, and 100% NPV. The combination of normal renal volume and a RFI below 1.5 ml/min/cm{sup 3} identified PTRA responders with a sensitivity of 91%, a specificity of 67%, a PPV of 71%, and a NPV of 89%. PTRA resulted in a greater increase in renal flow in responders compared with nonresponders (p < 0.001).Conclusion: A combination of cine phase-contrast MR renal flow and parenchymal volume measurements enables identification of patients benefiting from PTRA with a high sensitivity and NPV, but only moderate specificity and PPV.« less
Volume changes in unrestrained structural lightweight concrete.
DOT National Transportation Integrated Search
1964-08-01
In this study a comparator-type measuring system was developed to accurately determine volume change characteristics of one structural lightweight concrete. The specific properties studied were the coefficient of linear thermal expansion and unrestra...
Choi, Hyeok; Yang, Seong-Yoon; Cho, Hee-Seung; Kim, Woorim; Park, Eun-Cheol; Han, Kyu-Tae
2017-07-17
Many studies have assessed the volume-outcome relationship in cancer patients, but most focused on better outcomes in higher volume groups rather than identifying a specific threshold that could assist in clinical decision-making for achieving the best outcomes. The current study suggests an optimal volume for achieving good outcome, as an extension of previous studies on the volume-outcome relationship in stomach cancer patients. We used National Health Insurance Service (NHIS) Sampling Cohort data during 2004-2013, comprising healthcare claims for 2550 patients with newly diagnosed stomach cancer. We conducted survival analyses adopting the Cox proportional hazard model to investigate the association of three threshold values for surgical volume of stomach cancer patients for cancer-specific mortality using the Youden index. Overall, 17.10% of patients died due to cancer during the study period. The risk of mortality among patients who received surgical treatment gradually decreased with increasing surgical volume at the hospital, while the risk of mortality increased again in "high" surgical volume hospitals, resulting in a j-shaped curve (mid-low = hazard ratio (HR) 0.773, 95% confidence interval (CI) 0.608-0.983; mid-high = HR 0.541, 95% CI 0.372-0.788; high = HR 0.659, 95% CI 0.473-0.917; ref = low). These associations were especially significant in regions with unsubstantial surgical volumes and less severe cases. The optimal surgical volume threshold was about 727.3 surgical cases for stomach cancer per hospital over the 1-year study period in South Korea. However, such positive effects decreased after exceeding a certain volume of surgeries.
The effect of chronic erythrocytic polycythemia and high altitude upon plasma and blood volumes.
NASA Technical Reports Server (NTRS)
Burton, R. R.; Smith, A. H.
1972-01-01
Comparison of two kinds of physiological chronic erythrocytic polycythemias in order to differentiate the specific effect of erythrocytic polycythemia from the general effects of high altitude upon the plasma volume. The two kinds were produced hormonally in female chickens, at sea level, or by protracted high-altitude exposures. It appears that the vascular system of the body may account for an increase in red blood cell mass either by reduction in plasma volume, or by no change in plasma volume, resulting in differential changes in total blood volumes.
An Independent Scientific Assessment of Well Stimulation in California Volume II
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jane C.S. Long; Laura C. Feinstein; Corinne E. Bachmann
This study is issued in three volumes. Volume I, issued in January 2015, describes how well stimulation technologies work, how and where operators deploy these technologies for oil and gas production in California, and where they might enable production in the future. Volume II, the present volume, discusses how well stimulation could affect water, atmosphere, seismic activity, wildlife and vegetation, and human health. Volume II reviews available data, and identifies knowledge gaps and alternative practices that could avoid or mitigate these possible impacts. Volume III, also issued in July 2015, presents case studies that assess environmental issues and qualitative risksmore » for specific geographic regions. A final Summary Report summarizes key findings, conclusions and recommendations of all three volumes.« less
Hospital Volume and 30-Day Mortality for Three Common Medical Conditions
Ross, Joseph S.; Normand, Sharon-Lise T.; Wang, Yun; Ko, Dennis T.; Chen, Jersey; Drye, Elizabeth E.; Keenan, Patricia S.; Lichtman, Judith H.; Bueno, Héctor; Schreiner, Geoffrey C.; Krumholz, Harlan M.
2010-01-01
Background The association between hospital volume and the death rate for patients who are hospitalized for acute myocardial infarction, heart failure, or pneumonia remains unclear. It is also not known whether a volume threshold for such an association exists. Methods We conducted cross-sectional analyses of data from Medicare administrative claims for all fee-for-service beneficiaries who were hospitalized between 2004 and 2006 in acute care hospitals in the United States for acute myocardial infarction, heart failure, or pneumonia. Using hierarchical logistic-regression models for each condition, we estimated the change in the odds of death within 30 days associated with an increase of 100 patients in the annual hospital volume. Analyses were adjusted for patients’ risk factors and hospital characteristics. Bootstrapping procedures were used to estimate 95% confidence intervals to identify the condition-specific volume thresholds above which an increased volume was not associated with reduced mortality. Results There were 734,972 hospitalizations for acute myocardial infarction in 4128 hospitals, 1,324,287 for heart failure in 4679 hospitals, and 1,418,252 for pneumonia in 4673 hospitals. An increased hospital volume was associated with reduced 30-day mortality for all conditions (P<0.001 for all comparisons). For each condition, the association between volume and outcome was attenuated as the hospital's volume increased. For acute myocardial infarction, once the annual volume reached 610 patients (95% confidence interval [CI], 539 to 679), an increase in the hospital volume by 100 patients was no longer significantly associated with reduced odds of death. The volume threshold was 500 patients (95% CI, 433 to 566) for heart failure and 210 patients (95% CI, 142 to 284) for pneumonia. Conclusions Admission to higher-volume hospitals was associated with a reduction in mortality for acute myocardial infarction, heart failure, and pneumonia, although there was a volume threshold above which an increased condition-specific hospital volume was no longer significantly associated with reduced mortality. PMID:20335587
Code of Federal Regulations, 2011 CFR
2011-07-01
... spill mitigation procedures. (i) This subsection must describe the volume(s) and oil groups that would... applicable, the worst case discharge from the non-transportation-related facility. This must be the same volume provided in the response plan for the non-transportation-related facility. (ii) This subsection...
State Programs Supporting Health Manpower Training: An Inventory. Volume 1. Report and Tables.
ERIC Educational Resources Information Center
Public Health Service (DHEW), Washington, DC. Bureau of Health Manpower.
A detailed statistical review of state support for health manpower training during 1973, 1974, and 1975 with an inventory of state expenditures for specific health occupations in 32 states are presented in Volume One of this two-volume study conducted for the Health Resources Administration. Objectives of the study included: investigation of the…
Fire fighting aboard ships. Volume 1: Hazard analysis and behavior of combustible materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stavitskiy, M.G.; Kortunov, M.F.; Sidoryuk, V.M.
1983-01-01
The volume zeros in on fire hazards on ships afloat or under construction/repair. It examines fire hazards peculiar to ships carrying particular cargoes, such as dry-cargo ships, tankers, and factory and fishing vessels. This volume examines specific features of fire-fighting equipment, along with the thermal behavior of materials used in shipbuilding.
ERIC Educational Resources Information Center
Price Waterhouse and Co., New York, NY.
This volume on Phase II of the New York State Educational Information System (NYSEIS) describes the Gross Systems Analysis and Design, which includes the general flow diagram and processing chart for each of the student, personnel, and financial subsystems. Volume II, Functional Specifications, includes input/output requirements and file…
Xiaoping Zhou; Miles A. Hemstrom
2010-01-01
Timber availability, aboveground tree biomass, and changes in aboveground carbon pools are important consequences of landscape management. There are several models available for calculating tree volume and aboveground tree biomass pools. This paper documents species-specific regional equations for tree volume and aboveground live tree biomass estimation that might be...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-29
... notice provides the updated regional per-diem rates for low-volume mental health providers; the update... beneficiary per-diem cost-share amount for low-volume providers; and, the updated per-diem rates for both full... with high TRICARE volume) and regional-specific rates for psychiatric hospitals and units with low...
Evaluating percent within limits (PWL) specifications volume 1 : HMA specifications.
DOT National Transportation Integrated Search
2006-05-01
The Oklahoma Department of Transportation (ODOT) has let four paving jobs for construction where : percent within limits (PWL) specifications were employed. The PWL specifications are intended to be : used as part of the Quality Assessment program to...
Lambregts, Doenja M J; Rao, Sheng-Xiang; Sassen, Sander; Martens, Milou H; Heijnen, Luc A; Buijsen, Jeroen; Sosef, Meindert; Beets, Geerard L; Vliegen, Roy A; Beets-Tan, Regina G H
2015-12-01
Retrospective single-center studies have shown that diffusion-weighted magnetic resonance imaging (DWI) is promising for identification of patients with rectal cancer with a complete tumor response after neoadjuvant chemoradiotherapy (CRT), using certain volumetric thresholds. This study aims to validate the diagnostic value of these volume thresholds in a larger, independent, and bi-institutional patient cohort. A total of 112 patients with locally advanced rectal cancer (2 centers) treated with a long course of CRT were enrolled. Patients underwent standard T2W-magnetic resonance imaging and DWI, both pre- and post-CRT. Two experienced readers independently determined pre-CRT and post-CRT tumor volumes (cm) on T2W-magnetic resonance image and diffusion-weighted magnetic resonance image by means of freehand tumor delineation. Tumor volume reduction rates (Δvolume) were calculated. Previously determined T2W and DWI threshold values for prevolume, postvolume, and Δvolume were tested to "prospectively" assess their respective diagnostic value in discriminating patients with a complete tumor response from patients with residual tumor. Twenty patients had a complete response. Using the average measurements between the 2 readers, areas under the curve for the pre-/post-/Δvolumes was 0.73/0.82/0.78 for T2W-magnetic resonance imaging and 0.77/0.92/0.86 for DWI, respectively. For T2W-volumetry, sensitivity and specificity using the predefined volume thresholds were 55% and 74% for pre-, 60% and 89% for post-, and 60% and 86% for Δvolume. For DWI volumetry, sensitivity and specificity were 65% and 76% for pre-, 70% and 98% for post-, and 70% and 93% for Δvolume. Previously established DWI volume thresholds can be reproduced with good results. Post-CRT DWI volumetry offers the best results for the detection of patients with a complete response after CRT with an area under the curve of 0.92, sensitivity of 70%, and specificity of 98%.
1989-09-30
26 QUESTIONNAIRE INSTRUMENT ri. -I., DATA TABULATION VOLUMES This material provides information for use by readers to interpret...The second longitudinal Tabulation Volume reports the 1988 questionnaire responses of the junior enlisted "stayers" who were used as the sample to...the specific crossing variables used for the cross-sectional and longitudinal Tabulation Volumes. Cross-Sectional Tabulation Volumes. Demographic
Development of concrete shrinkage performance specifications.
DOT National Transportation Integrated Search
2003-01-01
During its service life, concrete undergoes volume changes. One of the types of deformation is shrinkage. The four main types of shrinkage associated with concrete are plastic, autogenous, carbonation, and drying shrinkage. The volume changes in conc...
Tanaka, Yutaka; Saito, Shigeru; Sasuga, Saeko; Takahashi, Azuma; Aoyama, Yusuke; Obama, Kazuto; Umezu, Mitsuo; Iwasaki, Kiyotaka
2018-05-01
Quantitative assessment of post-transcatheter aortic valve replacement (TAVR) aortic regurgitation (AR) remains challenging. We developed patient-specific anatomical models with pulsatile flow circuit and investigated factors associated with AR after TAVR. Based on pre-procedural computed tomography (CT) data of the six patients who underwent transfemoral TAVR using a 23-mm SAPIEN XT, anatomically and mechanically equivalent aortic valve models were developed. Forward flow and heart rate of each patient in two days after TAVR were duplicated under mean aortic pressure of 80mmHg. Paravalvular leakage (PVL) volume in basal and additional conditions was measured for each model using an electromagnetic flow sensor. Incompletely apposed tract between the transcatheter and aortic valves was examined using a micro-CT. PVL volume in each patient-specific model was consistent with each patient's PVL grade, and was affected by hemodynamic conditions. PVL and total regurgitation volume increased with the mean aortic pressure, whereas closing volume did not change. In contrast, closing volume increased proportionately with heart rate, but PVL did not change. The minimal cross-sectional gap had a positive correlation with the PVL volumes (r=0.89, P=0.02). The gap areas typically occurred in the vicinity of the bulky calcified nodules under the native commissure. PVL volume, which could be affected by hemodynamic conditions, was significantly associated with the minimal cross-sectional gap area between the aortic annulus and the stent frame. These data may improve our understanding of the mechanism of the occurrence of post-TAVR PVL. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Coverage-based constraints for IMRT optimization
NASA Astrophysics Data System (ADS)
Mescher, H.; Ulrich, S.; Bangert, M.
2017-09-01
Radiation therapy treatment planning requires an incorporation of uncertainties in order to guarantee an adequate irradiation of the tumor volumes. In current clinical practice, uncertainties are accounted for implicitly with an expansion of the target volume according to generic margin recipes. Alternatively, it is possible to account for uncertainties by explicit minimization of objectives that describe worst-case treatment scenarios, the expectation value of the treatment or the coverage probability of the target volumes during treatment planning. In this note we show that approaches relying on objectives to induce a specific coverage of the clinical target volumes are inevitably sensitive to variation of the relative weighting of the objectives. To address this issue, we introduce coverage-based constraints for intensity-modulated radiation therapy (IMRT) treatment planning. Our implementation follows the concept of coverage-optimized planning that considers explicit error scenarios to calculate and optimize patient-specific probabilities q(\\hat{d}, \\hat{v}) of covering a specific target volume fraction \\hat{v} with a certain dose \\hat{d} . Using a constraint-based reformulation of coverage-based objectives we eliminate the trade-off between coverage and competing objectives during treatment planning. In-depth convergence tests including 324 treatment plan optimizations demonstrate the reliability of coverage-based constraints for varying levels of probability, dose and volume. General clinical applicability of coverage-based constraints is demonstrated for two cases. A sensitivity analysis regarding penalty variations within this planing study based on IMRT treatment planning using (1) coverage-based constraints, (2) coverage-based objectives, (3) probabilistic optimization, (4) robust optimization and (5) conventional margins illustrates the potential benefit of coverage-based constraints that do not require tedious adjustment of target volume objectives.
Thermodynamics of a pure substance at the triple point
NASA Astrophysics Data System (ADS)
Velasco, S.; Fernández-Pineda, C.
2007-12-01
A thermodynamic study of a pure substance at the triple point is presented. In particular, we show that the mass fractions of the phases coexisting at the triple point obey lever rules in the specific entropy-specific volume diagram, and the relative changes in the mass fractions present in each phase along reversible isochoric and adiabatic processes of a pure substance at the triple point are governed by the relative sizes of the segments of the triple-point line in the pressure-specific volume diagram and in the temperature-specific entropy diagram. Applications to the ordinary triple point of water and to the triple point of Al2SiO5 polymorphs are presented.
ERIC Educational Resources Information Center
Clark, Beverly Lyon
This book is about the genre of school stories, that is, stories that deal with the education and the educational experiences of boys and girls. The book examines specific authors and specific works from the 1840s to the present, focusing on "crossgendering"--men writing about girls and women writing about boys. The chapters are, as…
Clinical laboratory: bigger is not always better.
Plebani, Mario
2018-06-27
Laboratory services around the world are undergoing substantial consolidation and changes through mechanisms ranging from mergers, acquisitions and outsourcing, primarily based on expectations to improve efficiency, increasing volumes and reducing the cost per test. However, the relationship between volume and costs is not linear and numerous variables influence the end cost per test. In particular, the relationship between volumes and costs does not span the entire platter of clinical laboratories: high costs are associated with low volumes up to a threshold of 1 million test per year. Over this threshold, there is no linear association between volumes and costs, as laboratory organization rather than test volume more significantly affects the final costs. Currently, data on laboratory errors and associated diagnostic errors and risk for patient harm emphasize the need for a paradigmatic shift: from a focus on volumes and efficiency to a patient-centered vision restoring the nature of laboratory services as an integral part of the diagnostic and therapy process. Process and outcome quality indicators are effective tools to measure and improve laboratory services, by stimulating a competition based on intra- and extra-analytical performance specifications, intermediate outcomes and customer satisfaction. Rather than competing with economic value, clinical laboratories should adopt a strategy based on a set of harmonized quality indicators and performance specifications, active laboratory stewardship, and improved patient safety.
Li, Hang; Chen, Tian-Wu; Li, Zhen-Lin; Zhang, Xiao-Ming; Li, Cheng-Jun; Chen, Xiao-Li; Chen, Guang-Wen; Hu, Jia-Ni; Ye, Yong-Quan
2015-01-01
AIM: To investigate whether liver lobe volume and albumin (ALB) could predict the presence and severity of liver cirrhosis, and esophageal varices. METHODS: Seventy-one cirrhotic patients with hepatitis B and 21 healthy individuals were enrolled in this study. All the participants underwent abdominal enhanced magnetic resonance imaging to measure each liver lobe volume, and biochemical workup for testing ALB and Child-Pugh class. All cirrhotic patients underwent upper gastrointestinal endoscopy to show the presence of cirrhotic esophageal varices. Right liver lobe volume (RV), left medial liver lobe volume (LMV), left lateral liver lobe volume (LLV), and caudate lobe volume (CV) were measured using enhanced magnetic resonance imaging. The ratios of RV to ALB (RV/ALB), LMV to ALB (LMV/ALB), LLV to ALB (LLV/ALB) and CV to ALB (CV/ALB) were calculated. Statistical analyses were performed to determine whether and how the combination of liver lobe volume measured using magnetic resonance imaging and albumin could predict the presence and severity of liver cirrhosis, and the presence of esophageal varices. RESULTS: RV, LMV, LLV and CV decreased (r = -0.51-0.373; all P < 0.05), while RV/ALB increased (r = 0.424; P < 0.05), with the progress of Child-Pugh class of liver cirrhosis. RV, LMV, CV, LLV/ALB and CV/ALB could identify presence of liver cirrhosis; LLV and LMV could distinguish Child-Pugh class A from B; RV, LMV, LLV, CV, RV/ALB and LLV/ALB could distinguish class A from C; RV and LLV/ALB could differentiate B from C; and RV, RV/ALB and CV/ALB could identify presence of esophageal varices (all P < 0.05). Among these parameters, CV/ALB could best identify the presence of liver cirrhosis, with an area under receiver operating characteristic curve (AUC) of 0.860, a sensitivity of 82.0% and a specificity of 83.0%. LLV could best distinguish class A from B, with an AUC of 0.761, a sensitivity of 74.4% and a specificity of 73.1%. RV could best distinguish class A from C, with an AUC of 0.900, a sensitivity of 90.3% and a specificity of 84.5%. LLV/ALB could best distinguish class B from C, with an AUC of 0.900, a sensitivity of 93.8% and a specificity of 81.5%. RV/ALB could best identify esophageal varices, with an AUC of 0.890, a sensitivity of 80.0% and a specificity of 83.5%. CONCLUSION: The combination of liver lobe volume and ALB has potential to identify presence and severity of cirrhosis, and presence of esophageal varices. PMID:25624735
Kryvenko, Oleksandr N; Balise, Raymond; Soodana Prakash, Nachiketh; Epstein, Jonathan I
2016-02-01
We assess the difference in prostate specific antigen production between African-American and Caucasian men with Gleason score 3+3=6 prostate cancer. We measured tumor volume in 414 consecutive radical prostatectomies from men with National Comprehensive Cancer Network(®) low risk prostate cancer (348 Caucasian, 66 African-American) who had Gleason score 3+3=6 disease at radical prostatectomy. We then compared clinical presentation, pathological findings, prostate specific antigen, prostate specific antigen density and prostate specific antigen mass (an absolute amount of prostate specific antigen in patient's circulation) between African-American and Caucasian men. The t-test and Wilcoxon rank sum were used for comparison of means. African-American and Caucasian men had similar clinical findings based on age, body mass index and prostate specific antigen. There were no statistically significant differences between the dominant tumor nodule volume and total tumor volume (mean 0.712 vs 0.665 cm(3), p=0.695) between African-American and Caucasian men. Prostates were heavier in African-American men (mean 55.4 vs 46.3 gm, p <0.03). Despite the significantly greater weight of benign prostate tissue contributing to prostate specific antigen in African-American men, prostate specific antigen mass was not different from that of Caucasian men (mean 0.55 vs 0.558 μg, p=0.95). Prostate specific antigen density was significantly less in African-American men due to larger prostates (mean 0.09 vs 0.105, p <0.02). African-American men with Gleason score 3+3=6 prostate cancer produce less prostate specific antigen than Caucasian men. African-American and Caucasian men had equal serum prostate specific antigen and prostate specific antigen mass despite significantly larger prostates in African-American men with all other parameters, particularly total tumor volume, being the same. This finding has practical implications in T1c cases diagnosed with prostate cancer due to prostate specific antigen screening. Lowering the prostate specific antigen density threshold in African-American men may account for this disparity, particularly in selecting patients for active surveillance programs. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Aagaard, James S.; And Others
This two-volume document specifies a protocol that was developed using the Reference Model for Open Systems Interconnection (OSI), which provides a framework for communications within a heterogeneous network environment. The protocol implements the features necessary for bibliographic searching, record maintenance, and mail transfer between…
What Would Be the Effect of Referral to High-Volume Hospitals in a Largely Rural State?
ERIC Educational Resources Information Center
Ward, Marcia M.; Jaana, Mirou; Wakefield, Douglas S.; Ohsfeldt, Robert L.; Schneider, John E.; Miller, Thomas; Lei, Yang
2004-01-01
Volume of certain surgical procedures has been linked to patient outcomes. The Leapfrog Group and others have recommended evidence-based referral using specific volume thresholds for nonemergent cases. The literature is limited on the effect of such referral on hospitals, especially in rural areas. To examine the impact of evidence-based referral…
Tree volume and biomass equations for the Lake States.
Jerold T. Hahn
1984-01-01
Presents species specific equations and methods for computing tree height, cubic foot, and board foot volume, and biomass for the Lake States (Michigan, Minnesota, and Wisconsin). Height equations compute either total or merchantable height to a variable top d.o.b. from d.b.h., site index, and basal area. Volumes and biomass are computed from d.b.h. and height.
Subcortical Correlates of Individual Differences in Aptitude
Jung, Rex E.; Ryman, Sephira G.; Vakhtin, Andrei A.; Carrasco, Jessica; Wertz, Chris; Flores, Ranee A.
2014-01-01
The study of individual differences encompasses broad constructs including intelligence, creativity, and personality. However, substantially less research is devoted to the study of specific aptitudes in spite of their importance to educational, occupational, and avocational success. We sought to determine subcortical brain structural correlates of several broad aptitudes including Math, Vocabulary, Foresight, Paper Folding, and Inductive Reasoning in a large (N = 107), healthy, young (age range = 16–29) cohort. Subcortical volumes were measured using an automated technique (FreeSurfer) across structures including bilateral caudate, putamen, globus pallidus, thalamus, nucleus accumbens, hippocampus, amygdala, and five equal regions of the corpus callosum. We found that performance on measures of each aptitude was predicted by different subcortical structures: Math – higher right nucleus accumbens volume; Vocabulary – higher left hippocampus volume; Paper Folding – higher right thalamus volume; Foresight – lower right thalamus and higher mid anterior corpus callosum volume; Inductive Reasoning – higher mid anterior corpus callosum volume. Our results support general findings, within the cognitive neurosciences, showing lateralization of structure-function relationships, as well as more specific relationships between individual structures (e.g., left hippocampus) and functions relevant to particular aptitudes (e.g., Vocabulary). PMID:24586770
NASA Technical Reports Server (NTRS)
Mueller, J. L. (Editor); Fargion, Giuletta S. (Editor); McClain, Charles R. (Editor); Pegau, Scott; Zaneveld, J. Ronald V.; Mitchell, B. Gregg; Kahru, Mati; Wieland, John; Stramska, Malgorzat
2003-01-01
This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 (Mueller and Fargion 2002, Volumes 1 and 2) is entirely superseded by the six volumes of Revision 4 listed above.
NASA Technical Reports Server (NTRS)
Mueller, J. L. (Editor); Fargion, Giulietta S. (Editor); McClain, Charles R. (Editor)
2003-01-01
This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 (Mueller and Fargion 2002, Volumes 1 and 2) is entirely superseded by the six volumes of Revision 4 listed above.
40 CFR 60.73a - Emissions testing and monitoring.
Code of Federal Regulations, 2013 CFR
2013-07-01
... system (e.g., weigh scale, volume flow meter, mass flow meter, tank volume) to measure and record the... via titration or by determining the temperature and specific gravity of the nitric acid. You may also...
40 CFR 60.73a - Emissions testing and monitoring.
Code of Federal Regulations, 2014 CFR
2014-07-01
... system (e.g., weigh scale, volume flow meter, mass flow meter, tank volume) to measure and record the... via titration or by determining the temperature and specific gravity of the nitric acid. You may also...
DOT National Transportation Integrated Search
2013-06-01
The objective of the proposed study is to design, test, and evaluate high-volume fly ash concrete mixtures. Traditional specifications : limit the amount of fly ash to 40% or less cement replacement. This program attempts to increase the ash content ...
Volume of the human septal forebrain region is a predictor of source memory accuracy.
Butler, Tracy; Blackmon, Karen; Zaborszky, Laszlo; Wang, Xiuyuan; DuBois, Jonathan; Carlson, Chad; Barr, William B; French, Jacqueline; Devinsky, Orrin; Kuzniecky, Ruben; Halgren, Eric; Thesen, Thomas
2012-01-01
Septal nuclei, components of basal forebrain, are strongly and reciprocally connected with hippocampus, and have been shown in animals to play a critical role in memory. In humans, the septal forebrain has received little attention. To examine the role of human septal forebrain in memory, we acquired high-resolution magnetic resonance imaging scans from 25 healthy subjects and calculated septal forebrain volume using recently developed probabilistic cytoarchitectonic maps. We indexed memory with the California Verbal Learning Test-II. Linear regression showed that bilateral septal forebrain volume was a significant positive predictor of recognition memory accuracy. More specifically, larger septal forebrain volume was associated with the ability to recall item source/context accuracy. Results indicate specific involvement of septal forebrain in human source memory, and recall the need for additional research into the role of septal nuclei in memory and other impairments associated with human diseases.
NASA-STD 3001 and the Human Integration Design Handbook (HIDH): Evolution of NASA-STD-3000
NASA Technical Reports Server (NTRS)
Pickett, Lynn; Connolly, Janis; Arch, M.; Tillman, Barry; Russo, Dane
2007-01-01
The Habitability & Environmental Factors and Space Medicine Divisions have developed the Space Flight Human System Standard (SFHSS) (NASA-STD-3001) to replace NASA-STD-3000 as a new NASA standard for all human spaceflight programs. The SFHSS is composed of 2 volumes. Volume 1, Crew Health, contains medical levels of care, permissible exposure limits, and fitness for duty criteria, and permissible outcome limits as a means of defining successful operating criteria for the human system. Volume 2, Habitability and Environmental Health, contains environmental, habitability and human factors standards. Development of the Human Integration Design Handbook (HIDH), a companion to the standard, is currently under construction and entails the update and revision of NASA-STD-3000 data. This new handbook will, in the fashion of NASA STD-3000, assist engineers and designers in appropriately applying habitability, environmental and human factors principles to spacecraft design. Organized in a chapter-module-element structure, the HIDH will provide the guidance for the development of requirements, design considerations, lessons learned, example solutions, background research, and assist in the identification of gaps and research needs in the disciplines. Subject matter experts have been and continue to be solicited to participate in the update of the chapters. The purpose is to build the HIDH with the best and latest data, and provide a broad representation from experts in industry, academia, the military and the space program. The handbook and the two standards volumes work together in a unique way to achieve the required level of human-system interface. All new NASA programs will be required to meet Volumes 1 and 2. Volume 2 presents human interface goals in broad, non-verifiable standards. Volume 2 also requires that each new development program prepare a set of program-specific human factors requirements. These program-specific human and environmental factors requirements must be verifiable and tailored to assure the new system meets the Volume 2 standards. Programs will use the HIDH to write their verifiable program-specific requirements.
Mastalerz, Maria; Drobniak, A.; Strapoc, D.; Solano-Acosta, W.; Rupp, J.
2008-01-01
The Seelyville Coal Member of the Linton Formation (Pennsylvanian) in Indiana was studied to: 1) understand variations in pore characteristics within a coal seam at a single location and compare these variations with changes occurring between the same coal at different locations, 2) elaborate on the influence of mineral-matter and maceral composition on mesopore and micropore characteristics, and 3) discuss implications of these variations for coal bed gas content. The coal is high volatile bituminous rank with R0 ranging from 0.57% to 0.60%. BET specific surface areas (determined by nitrogen adsorption) of the coals samples studied range from 1.8 to 22.9??m2/g, BJH adsorption mesopore volumes from 0.0041 to 0.0339??cm3/g, and micropore volumes (determined by carbon dioxide adsorption) from 0.0315 to 0.0540??cm3/g. The coals that had the largest specific surface areas and largest mesopore volumes occur at the shallowest depths, whereas the smallest values for these two parameters occur in the deepest coals. Micropore volumes, in contrast, are not depth-dependent. In the coal samples examined for this study, mineral-matter content influenced both specific surface area as well as mesopore and micropore volumes. It is especially clear in the case of micropores, where an increase in mineral-matter content parallels the decrease of micropore volume of the coal. No obvious relationships were observed between the total vitrinite content and pore characteristics but, after splitting vitrinite into individual macerals, we see that collotelinite influences both meso- and micropore volume positively, whereas collodetrinite contributes to the reduction of mesopore and micropore volumes. There are large variations in gas content within a single coal at a single location. Because of this variability, the entire thickness of the coal must be desorbed in order to determine gas content reliably and to accurately calculate the level of gas saturation. ?? 2008 Elsevier B.V. All rights reserved.
Deformations of amygdala morphology in familial pediatric bipolar disorder.
Kelley, Ryan; Chang, Kiki D; Garrett, Amy; Alegría, Dylan; Thompson, Paul; Howe, Meghan; L Reiss, Allan
2013-11-01
Smaller amygdalar volumes have been consistently observed in pediatric bipolar disorder subjects compared to healthy control subjects. Whether smaller amygdalar volume is a consequence or antecedent of the first episode of mania is not known. Additionally, smaller volume has not been localized to specific amygdala subregions. We compared surface contour maps of the amygdala between 22 youths at high risk for bipolar disorder, 26 youths meeting full diagnostic criteria for pediatric familial bipolar disorder, and 24 healthy control subjects matched for age, gender, and intelligence quotient. Amygdalae were manually delineated on three-dimensional spoiled gradient echo images by a blinded rater using established tracing protocols. Statistical surface mesh modeling algorithms supported by permutation statistics were used to identify regional surface differences between the groups. When compared to high-risk subjects and controls, youth with bipolar disorder showed surface deformations in specific amygdalar subregions, suggesting smaller volume of the basolateral nuclei. The high-risk subjects did not differ from controls in any subregion. These findings support previous reports of smaller amygdala volume in pediatric bipolar disorder and map the location of abnormality to specific amygdala subregions. These subregions have been associated with fear conditioning and emotion-enhanced memory. The absence of amygdala size abnormalities in youth at high risk for bipolar disorder suggests that reductions might occur after the onset of mania. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Assured crew return vehicle man-systems integration standards
NASA Technical Reports Server (NTRS)
1991-01-01
This is Volume 6 of the Man-Systems Integration Standards (MSIS) family of documents, which is contained in several volumes and a relational database. Each volume has a specific purpose, and each has been assembled from the data contained in the relational database. Volume 6 serves as the Assured Crew Return Vehicle project man-systems integration design requirements. The data in this document is a subset of the data found in Volume 1 and defines the requirements which are pertinent to the Assured Crew Return Vehicle as defined in the SPRD. Additional data and guidelines are provided to assist in the design.
Narita, Shintaro; Mitsuzuka, Koji; Tsuchiya, Norihiko; Koie, Takuya; Kawamura, Sadafumi; Ohyama, Chikara; Tochigi, Tatsuo; Yamaguchi, Takuhiro; Arai, Yoichi; Habuchi, Tomonori
2015-11-01
To assess the risk factors for biochemical recurrence in D'Amico intermediate-risk prostate cancer patients treated using radical prostatectomy. We retrospectively reviewed the medical records of 1268 men with prostate cancer treated using radical prostatectomy without neoadjuvant therapy. The association between various risk factors and biochemical recurrence was then statistically evaluated. The Kaplan-Meier method, log-rank tests and Cox proportional hazards models were used for statistical analysis. In the intermediate-risk group, 96 patients (14.5%) experienced biochemical recurrence during a median follow up of 41 months. In the intermediate-risk group, preoperative prostate-specific antigen level, prostate volume and prostate-specific antigen density were significant preoperative risk factors for biochemical recurrence, whereas other factors including age, primary Gleason 4, clinical stage >T2 and percentage of positive biopsies were not. In multivariate analysis, higher preoperative prostate-specific antigen level and density, and a smaller prostate volume were independent risk factors for biochemical recurrence in the intermediate-risk group. Biochemical recurrence-free survival of patients in the intermediate-risk group with a higher prostate-specific antigen level and density (≥15 ng/mL, ≥0.6 ng/mL/cm(3), respectively), and lower prostate volume (≤10 mL) was comparable with that of high-risk group individuals (P = 0.632, 0.494 and 0.961, respectively). Preoperative prostate-specific antigen, prostate volume and prostate-specific antigen density are significant risk factors for biochemical recurrence in D'Amico intermediate-risk prostate cancer patients treated using radical prostatectomy. Using these variables, a subset of the intermediate-risk patients can be identified as having equivalent outcomes to high-risk patients. © 2015 The Japanese Urological Association.
Watson, Kathleen B.; Dai, Shifan; Paul, Prabasaj; Carlson, Susan A.; Carroll, Dianna D.; Fulton, Janet E.
2017-01-01
Background Previous studies have examined participation in specific leisure-time physical activities (PA) among US adults. The purpose of this study was to identify specific activities that contribute substantially to total volume of leisure-time PA in US adults. Methods Proportion of total volume of leisure-time PA moderate-equivalent minutes attributable to 9 specific types of activities was estimated using self-reported data from 21,685 adult participants (≥ 18 years) in the National Health and Nutrition Examination Survey 1999–2006. Results Overall, walking (28%), sports (22%), and dancing (9%) contributed most to PA volume. Attributable proportion was higher among men than women for sports (30% vs. 11%) and higher among women than men for walking (36% vs. 23%), dancing (16% vs. 4%), and conditioning exercises (10% vs. 5%). The proportion was lower for walking, but higher for sports, among active adults than those insufficiently active and increased with age for walking. Compared with other racial/ethnic groups, the proportion was lower for sports among non-Hispanic white men and for dancing among non-Hispanic white women. Conclusions Walking, sports, and dance account for the most activity time among US adults overall, yet some demographic variations exist. Strategies for PA promotion should be tailored to differences across population subgroups. PMID:27335226
Bristow, Robert E; Chang, Jenny; Ziogas, Argyrios; Randall, Leslie M; Anton-Culver, Hoda
2014-02-01
To characterize the impact of hospital and physician ovarian cancer case volume on survival for advanced-stage disease and investigate socio-demographic variables associated with access to high-volume providers. Consecutive patients with stage IIIC/IV epithelial ovarian cancer (1/1/96-12/31/06) were identified from the California Cancer Registry. Disease-specific survival analysis was performed using Cox-proportional hazards model. Multivariate logistic regression analyses were used to evaluate for differences in access to high-volume hospitals (HVH) (≥20 cases/year), high-volume physicians (HVP) (≥10 cases/year), and cross-tabulations of high- or low-volume hospital (LVH) and physician (LVP) according to socio-demographic variables. A total of 11,865 patients were identified. The median ovarian cancer-specific survival for all patients was 28.2 months, and on multivariate analysis the HVH/HVP provider combination (HR = 1.00) was associated with superior ovarian cancer-specific survival compared to LVH/LVP (HR = 1.31, 95%CI = 1.16-1.49). Overall, 2119 patients (17.9%) were cared for at HVHs, and 1791 patients (15.1%) were treated by HVPs. Only 4.3% of patients received care from HVH/HVP, while 53.1% of patients were treated by LVH/LVP. Both race and socio-demographic characteristics were independently associated with an increased likelihood of being cared for by the LVH/LVP combination and included: Hispanic race (OR = 1.72, 95%CI = 1.22-2.42), Asian/Pacific Islander race (OR = 1.57, 95%CI = 1.07-2.32), Medicaid insurance (OR = 2.51, 95%CI = 1.46-4.30), and low socioeconomic status (OR = 2.84, 95%CI = 1.90-4.23). Among patients with advanced-stage ovarian cancer, the provider combination of HVH/HVP is an independent predictor of improved disease-specific survival. Access to high-volume ovarian cancer providers is limited, and barriers are more pronounced for patients with low socioeconomic status, Medicaid insurance, and racial minorities. Copyright © 2013 Elsevier Inc. All rights reserved.
Probabilistic brain tissue segmentation in neonatal magnetic resonance imaging.
Anbeek, Petronella; Vincken, Koen L; Groenendaal, Floris; Koeman, Annemieke; van Osch, Matthias J P; van der Grond, Jeroen
2008-02-01
A fully automated method has been developed for segmentation of four different structures in the neonatal brain: white matter (WM), central gray matter (CEGM), cortical gray matter (COGM), and cerebrospinal fluid (CSF). The segmentation algorithm is based on information from T2-weighted (T2-w) and inversion recovery (IR) scans. The method uses a K nearest neighbor (KNN) classification technique with features derived from spatial information and voxel intensities. Probabilistic segmentations of each tissue type were generated. By applying thresholds on these probability maps, binary segmentations were obtained. These final segmentations were evaluated by comparison with a gold standard. The sensitivity, specificity, and Dice similarity index (SI) were calculated for quantitative validation of the results. High sensitivity and specificity with respect to the gold standard were reached: sensitivity >0.82 and specificity >0.9 for all tissue types. Tissue volumes were calculated from the binary and probabilistic segmentations. The probabilistic segmentation volumes of all tissue types accurately estimated the gold standard volumes. The KNN approach offers valuable ways for neonatal brain segmentation. The probabilistic outcomes provide a useful tool for accurate volume measurements. The described method is based on routine diagnostic magnetic resonance imaging (MRI) and is suitable for large population studies.
Memory disorders in probable Alzheimer's disease: the role of hippocampal atrophy as shown with MRI.
Deweer, B; Lehéricy, S; Pillon, B; Baulac, M; Chiras, J; Marsault, C; Agid, Y; Dubois, B
1995-01-01
Magnetic resonance based volumetric measures of hippocampal formation, amygdala (A), caudate nucleus (CN), normalised for total intracranial volume (TIV), were analysed in relation to measures of cognitive deterioration and specific features of memory functions in 18 patients with probable Alzheimer's disease. Neuropsychological examination included the mini mental state examination (MMSE), the Mattis dementia rating scale (DRS), tests of executive functions, assessment of language abilities and praxis, the Wechsler memory scale (WMS), the California verbal learning test (CVLT) and the Grober and Buschke test. The volume of the hippocampal formation (HF/TIV) was correlated with specific memory variables: memory quotient and paired associates of the WMS; intrusions and discriminability at recognition for the Grober and Buschke test. By contrast, except for intrusions, no correlations were found between memory variables and the volume of amygdala (A/TIV). No correlations were found between the volume of caudate nuclei (CN/TIV) and any neuropsychological score. The volume of the hippocampal formation was therefore selectively related to quantitative and qualitative aspects of memory performance in patients with probable Alzheimer's disease. Images PMID:7745409
Auditory cortical volumes and musical ability in Williams syndrome.
Martens, Marilee A; Reutens, David C; Wilson, Sarah J
2010-07-01
Individuals with Williams syndrome (WS) have been shown to have atypical morphology in the auditory cortex, an area associated with aspects of musicality. Some individuals with WS have demonstrated specific musical abilities, despite intellectual delays. Primary auditory cortex and planum temporale volumes were manually segmented in 25 individuals with WS and 25 control participants, and the participants also underwent testing of musical abilities. Left and right planum temporale volumes were significantly larger in the participants with WS than in controls, with no significant difference noted between groups in planum temporale asymmetry or primary auditory cortical volumes. Left planum temporale volume was significantly increased in a subgroup of the participants with WS who demonstrated specific musical strengths, as compared to the remaining WS participants, and was highly correlated with scores on a musical task. These findings suggest that differences in musical ability within WS may be in part associated with variability in the left auditory cortical region, providing further evidence of cognitive and neuroanatomical heterogeneity within this syndrome. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
Comparison of Rectal and Esophageal Sensitivity in Women With Functional Heartburn.
Freede, Margaret; Leasure, A Renee; Proskin, Howard M; Hatch, Daniel; Edwards, Karethy; Pascucci, MaryAnn; Smith, Patsy R
2016-01-01
This study tested the primary hypothesis that there is a correlation of maximum pain threshold (MPT) in the esophagus and rectum in persons with functional heartburn. Secondary aims evaluated correlations with initial perception threshold (IPT) and pain threshold (PT). This study explored objective sensory endpoints of IPT, PT, and MPT in the esophagus and rectum of 14 females with functional heartburn to determine whether visceral hypersensitivity is generalized or organ-specific. Data on volume and pressure measurements at IPT, PT, and MPT with esophageal and rectal barostat distention were collected. The relationship of sensation and pain to volume, pressure, and compliance was analyzed. Esophageal and rectal IPT balloon volume scores were highly and significantly correlated (r = .61, p = .02). Esophageal and rectal PT balloon volume scores were highly and significantly correlated (r = .6, p = .02). Esophageal and rectal MPT balloon volume scores were not correlated (r = .35, p = .26). The correlation of visceral sensitivity in the esophagus and rectum in persons with functional heartburn supports the hypothesis that visceral sensory changes in functional gastrointestinal disorders are not organ specific.
Method for preparing small volume reaction containers
Retterer, Scott T.; Doktycz, Mitchel J.
2017-04-25
Engineered reaction containers that can be physically and chemically defined to control the flux of molecules of different sizes and charge are disclosed. Methods for constructing small volume reaction containers through a combination of etching and deposition are also disclosed. The methods allow for the fabrication of multiple devices that possess features on multiple length scales, specifically small volume containers with controlled porosity on the nanoscale.
Don Minore; Donald R. Gedney
1960-01-01
A large proportion of present-day timber cruising is done by measuring or estimating three tree dimensions: diameter at breast height, form class, and merchantable height. Tree volumes are then determined from tables which equate volume to the varying combinations of height, d.b.h., and form class. Assumptions concerning merchantable height were made in constructing...
Pinevol: a user's guide to a volume calculator for southern pines
Daniel J. Leduc
2006-01-01
Taper functions describe a model of the actual geometric shape of a tree. When this shape is assumed to be known, volume by any log rule and to any merchantability standard can be calculated. PINEVOL is a computer program for calculating the volume of the major southern pines using species-specific bole taper functions. It can use the Doyle, Scribner, or International...
NASA Astrophysics Data System (ADS)
Karasawa, Kenichi; Oda, Masahiro; Hayashi, Yuichiro; Nimura, Yukitaka; Kitasaka, Takayuki; Misawa, Kazunari; Fujiwara, Michitaka; Rueckert, Daniel; Mori, Kensaku
2015-03-01
Abdominal organ segmentations from CT volumes are now widely used in the computer-aided diagnosis and surgery assistance systems. Among abdominal organs, the pancreas is especially difficult to segment because of its large individual differences of the shape and position. In this paper, we propose a new pancreas segmentation method from 3D abdominal CT volumes using patient-specific weighted-subspatial probabilistic atlases. First of all, we perform normalization of organ shapes in training volumes and an input volume. We extract the Volume Of Interest (VOI) of the pancreas from the training volumes and an input volume. We divide each training VOI and input VOI into some cubic regions. We use a nonrigid registration method to register these cubic regions of the training VOI to corresponding regions of the input VOI. Based on the registration results, we calculate similarities between each cubic region of the training VOI and corresponding region of the input VOI. We select cubic regions of training volumes having the top N similarities in each cubic region. We subspatially construct probabilistic atlases weighted by the similarities in each cubic region. After integrating these probabilistic atlases in cubic regions into one, we perform a rough-to-precise segmentation of the pancreas using the atlas. The results of the experiments showed that utilization of the training volumes having the top N similarities in each cubic region led good results of the pancreas segmentation. The Jaccard Index and the average surface distance of the result were 58.9% and 2.04mm on average, respectively.
NASA Technical Reports Server (NTRS)
Mueller, J. L.; Fargion, G. S.; McClain, C. R. (Editor); Pegau, S.; Zanefeld, J. R. V.; Mitchell, B. G.; Kahru, M.; Wieland, J.; Stramska, M.
2003-01-01
This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparision and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background, and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 is entirely superseded by the six volumes of Revision 4 listed above.
An experimental result of estimating an application volume by machine learning techniques.
Hasegawa, Tatsuhito; Koshino, Makoto; Kimura, Haruhiko
2015-01-01
In this study, we improved the usability of smartphones by automating a user's operations. We developed an intelligent system using machine learning techniques that periodically detects a user's context on a smartphone. We selected the Android operating system because it has the largest market share and highest flexibility of its development environment. In this paper, we describe an application that automatically adjusts application volume. Adjusting the volume can be easily forgotten because users need to push the volume buttons to alter the volume depending on the given situation. Therefore, we developed an application that automatically adjusts the volume based on learned user settings. Application volume can be set differently from ringtone volume on Android devices, and these volume settings are associated with each specific application including games. Our application records a user's location, the volume setting, the foreground application name and other such attributes as learning data, thereby estimating whether the volume should be adjusted using machine learning techniques via Weka.
Choi, Kwangseok; Taghavivand, Milad; Zhang, Lifeng
2017-03-15
Pharmaceutical powders are mainly organic materials and are likely to be charged due to repeated inter-particle and particle-wall contacts during industrial processes. This study experimentally investigated the effect of moisture content (ranging from approximately 1.8 to 30wt.%) on tribocharging behaviour of pharmaceutical granules, as well as their apparent volume resistivity. The tribocharging behaviour of pharmaceutical granules was investigated using a rotating device and apparent volume resistivity was measured in a conventional volume resistivity test cell. Additional measurements were performed on individual ingredients, each having the same moisture content as that of the granules, in order to investigate the effect of each single ingredient on the apparent volume resistivity of granules. In this work, the individual ingredients used for granules were: α-Lactose Monohydrate (α-LMH), Microcrystalline Cellulose (MCC), Hydroxypropyl Methylcellulose (HPMC), and Croscarmellose Sodium (CCS). The results showed that the specific charge of granules began to increase at the moisture contents below 5wt.%, which can be referred as critical moisture content of granules. The apparent volume resistivity showed the same behaviour, indicating that the specific charge could be due to an increase in apparent volume resistivity of granules at reduced moisture content. Finally, it was shown that the apparent volume resistivity measured for granules was mainly affected by that of the α-LMH, the major component of granules accounting for 40wt.%. Copyright © 2017 Elsevier B.V. All rights reserved.
Page, Stephanie T; Hirano, Lianne; Gilchriest, Janet; Dighe, Manjiri; Amory, John K; Marck, Brett T; Matsumoto, Alvin M
2011-07-01
Benign prostatic hyperplasia and hypogonadism are common disorders in aging men. There is concern that androgen replacement in older men may increase prostate size and symptoms of benign prostatic hyperplasia. We examined whether combining dutasteride, which inhibits testosterone to dihydrotestosterone conversion, with testosterone treatment in older hypogonadal men with benign prostatic hyperplasia reduces androgenic stimulation of the prostate compared to testosterone alone. We conducted a double-blind, placebo controlled trial of 53 men 51 to 82 years old with symptomatic benign prostatic hyperplasia, prostate volume 30 cc or greater and serum total testosterone less than 280 ng/dl (less than 9.7 nmol/l). Subjects were randomized to daily transdermal 1% T gel plus oral placebo or dutasteride for 6 months. Testosterone dosing was adjusted to a serum testosterone of 500 to 1,000 ng/dl. The primary outcomes were prostate volume measured by magnetic resonance imaging, serum prostate specific antigen and androgen levels. A total of 46 subjects completed all procedures. Serum testosterone increased similarly into the mid-normal range in both groups. Serum dihydrotestosterone increased in the testosterone only but decreased in the testosterone plus dutasteride group. In the testosterone plus dutasteride group prostate volume and prostate specific antigen (mean ± SEM) decreased 12% ± 2.5% and 35% ± 5%, respectively, compared to the testosterone only group in which prostate volume and prostate specific antigen increased 7.5% ± 3.3% and 19% ± 7% (p = 0.03 and p = 0.008), respectively, after 6 months of treatment. Prostate symptom scores improved in both groups. Combined treatment with testosterone plus dutasteride reduces prostate volume and prostate specific antigen compared to testosterone only. Coadministration of a 5α-reductase inhibitor with testosterone appears to spare the prostate from androgenic stimulation during testosterone replacement in older, hypogonadal men with symptomatic benign prostatic hyperplasia. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Ding, Kai; Cao, Kunlin; Fuld, Matthew K.; Du, Kaifang; Christensen, Gary E.; Hoffman, Eric A.; Reinhardt, Joseph M.
2012-01-01
Purpose: Regional lung volume change as a function of lung inflation serves as an index of parenchymal and airway status as well as an index of regional ventilation and can be used to detect pathologic changes over time. In this paper, the authors propose a new regional measure of lung mechanics—the specific air volume change by corrected Jacobian. The authors compare this new measure, along with two existing registration based measures of lung ventilation, to a regional ventilation measurement derived from xenon-CT (Xe-CT) imaging. Methods: 4DCT and Xe-CT datasets from four adult sheep are used in this study. Nonlinear, 3D image registration is applied to register an image acquired near end inspiration to an image acquired near end expiration. Approximately 200 annotated anatomical points are used as landmarks to evaluate registration accuracy. Three different registration based measures of regional lung mechanics are derived and compared: the specific air volume change calculated from the Jacobian (SAJ); the specific air volume change calculated by the corrected Jacobian (SACJ); and the specific air volume change by intensity change (SAI). The authors show that the commonly used SAI measure can be derived from the direct SAJ measure by using the air-tissue mixture model and assuming there is no tissue volume change between the end inspiration and end expiration datasets. All three ventilation measures are evaluated by comparing to Xe-CT estimates of regional ventilation. Results: After registration, the mean registration error is on the order of 1 mm. For cubical regions of interest (ROIs) in cubes with size 20 mm × 20 mm × 20 mm, the SAJ and SACJ measures show significantly higher correlation (linear regression, average r2 = 0.75 and r2 = 0.82) with the Xe-CT based measure of specific ventilation (sV) than the SAI measure. For ROIs in slabs along the ventral-dorsal vertical direction with size of 150 mm × 8 mm × 40 mm, the SAJ, SACJ, and SAI all show high correlation (linear regression, average r2 = 0.88, r2 = 0.92, and r2 = 0.87) with the Xe-CT based sV without significant differences when comparing between the three methods. The authors demonstrate a linear relationship between the difference of specific air volume change and difference of tissue volume in all four animals (linear regression, average r2 = 0.86). Conclusions: Given a deformation field by an image registration algorithm, significant differences between the SAJ, SACJ, and SAI measures were found at a regional level compared to the Xe-CT sV in four sheep that were studied. The SACJ introduced here, provides better correlations with Xe-CT based sV than the SAJ and SAI measures, thus providing an improved surrogate for regional ventilation. PMID:22894434
Assessment of a media campaign and related crisis help line following Hurricane Katrina.
Beaudoin, Christopher E
2008-01-01
We evaluated the impact of a media campaign targeting stress and depression following Hurricane Katrina. We specifically examined public response to the campaign's recommendation that people could contact a telephone help line for further assistance if needed. Call data from Via Link allowed us to track trends in 800-number Crisis Line call volume (n = 29,659), which is the number recommended in the media campaign, and 2-1-1 Information and Referral Line call volume (n = 8,035), which is employed in a control-like manner. With data from April 1, 2006, through November 30, 2006, multivariate analysis was used to assess trends and differences among and within pre-intervention, intervention, and post-intervention. Information and Referral Line call volume, which was unrelated to the campaign, did not change over time. In contrast, Crisis Line call volume, which was related to the campaign, increased significantly from pre-intervention to intervention, but not from intervention to post-intervention. Furthermore, the daily rate of Crisis Line call volume was constant during pre-intervention, increased during intervention, but decreased during post-intervention. There is support for the media campaign's influence on public behavior to contact Via Link in regard to stress and depression following Hurricane Katrina. Analysis helps undermine alternative explanations, including general trends in help line call volume and those specific to Crisis Line call volume.
A voxel-based investigation of brain structure in male adolescents with autistic spectrum disorder.
Waiter, Gordon D; Williams, Justin H G; Murray, Alison D; Gilchrist, Anne; Perrett, David I; Whiten, Andrew
2004-06-01
Autistic spectrum disorder (ASD) has been associated with abnormal neuroanatomy in many imaging and neuropathological studies. Both global brain volume differences and differences in the size of specific neural structures have been reported. Here, we report a voxel-based morphometric whole brain analysis, using a group specific template, on 16 individuals of normal intelligence with autistic spectrum disorder (ASD), and a group of 16 age-, sex- and IQ-matched controls. Total grey matter volume was increased in the ASD group relative to the control group, with local volume increases in the right fusiform gyrus, the right temporo-occipital region and the left frontal pole extending to the medial frontal cortex. A local decrease in grey matter volume was found in the right thalamus. A decrease in global white matter volume in the ASD group did not reach significance. We found the increase in grey matter volume in ASD subjects was greatest in those areas recognised for their role in social cognition, particularly face recognition (right fusiform gyrus), mental state attribution: 'theory of mind' (anterior cingulate and superior temporal sulcus) and perception of eye gaze (superior temporal gyrus). The picture as a whole may reflect an abnormally functioning social cognitive neural network. We suggest that increased grey matter volume may play a pivotal role in the aetiology of the autistic syndrome.
Extraction of citral oil from lemongrass (Cymbopogon Citratus) by steam-water distillation technique
NASA Astrophysics Data System (ADS)
Alam, P. N.; Husin, H.; Asnawi, T. M.; Adisalamun
2018-04-01
In Indonesia, production of citral oil from lemon grass (Cymbopogon Cytratus) is done by a traditional technique whereby a low yield results. To improve the yield, an appropriate extraction technology is required. In this research, a steam-water distillation technique was applied to extract the essential oil from the lemongrass. The effects of sample particle size and bed volume on yield and quality of citral oil produced were investigated. The drying and refining time of 2 hours were used as fixed variables. This research results that minimum citral oil yield of 0.53% was obtained on sample particle size of 3 cm and bed volume of 80%, whereas the maximum yield of 1.95% on sample particle size of 15 cm and bed volume of 40%. The lowest specific gravity of 0.80 and the highest specific gravity of 0.905 were obtained on sample particle size of 8 cm with bed volume of 80% and particle size of 12 cm with bed volume of 70%, respectively. The lowest refractive index of 1.480 and the highest refractive index of 1.495 were obtained on sample particle size of 8 cm with bed volume of 70% and sample particle size of 15 cm with bed volume of 40%, respectively. The solubility of the produced citral oil in alcohol was 70% in ratio of 1:1, and the citral oil concentration obtained was around 79%.
An application specific integrated circuit based multi-anode microchannel array readout system
NASA Technical Reports Server (NTRS)
Smeins, Larry G.; Stechman, John M.; Cole, Edward H.
1991-01-01
Size reduction of two new multi-anode microchannel array (MAMA) readout systems is described. The systems are based on two analog and one digital application specific integrated circuits (ASICs). The new readout systems reduce volume over previous discrete designs by 80 percent while improving electrical performance on virtually every significant parameter. Emphasis is made on the packaging used to achieve the volume reduction. Surface mount technology (SMT) is combined with modular construction for the analog portion of the readout. SMT reliability concerns and the board area impact of MIL SPEC SMT components is addressed. Package selection for the analog ASIC is discussed. Future sytems will require even denser packaging and the volume reduction progression is shown.
Sensors, Volume 4, Thermal Sensors
NASA Astrophysics Data System (ADS)
Scholz, Jorg; Ricolfi, Teresio
1996-12-01
'Sensors' is the first self-contained series to deal with the whole area of sensors. It describes general aspects, technical and physical fundamentals, construction, function, applications and developments of the various types of sensors. This volume describes the construction and applicational aspects of thermal sensors while presenting a rigorous treatment of the underlying physical principles. It provides a unique overview of the various categories of sensors as well as of specific groups, e.g. temperature sensors (resistance thermometers, thermocouples, and radiation thermometers), noise and acoustic thermometers, heat-flow and mass-flow sensors. Specific facettes of applications are presented by specialists from different fields including process control, automotive technology and cryogenics. This volume is an indispensable reference work and text book for both specialists and newcomers, researchers and developers.
Influence of pressure on pyrolysis of black liquor: 1. Swelling.
Whitty, Kevin; Backman, Rainer; Hupa, Mikko
2008-02-01
This is the first of two papers concerning the behavior of black liquor during pyrolysis under pressurized conditions. Two industrial kraft liquors were pyrolyzed in a laboratory-scale pressurized single particle reactor and a pressurized grid heater at temperatures ranging from 650 to 1100 degrees C and at pressures between 1 and 20 bar. The dimensions of the chars produced were measured and the specific swollen volume was calculated. Swelling decreased roughly logarithmically over the pressure range 1-20 r. An expression is developed to predict the specific swollen volume at elevated pressure when the volume at 1 bar is known. The bulk density of the char increased with pressure, indicating that liquors will be entrained less easily at higher pressures.
Hinaman, Kurt
2005-01-01
The Powder River Basin in Wyoming and Montana is an important source of energy resources for the United States. Coalbed methane gas is contained in Tertiary and upper Cretaceous hydrogeologic units in the Powder River Basin. This gas is released when water pressure in coalbeds is lowered, usually by pumping ground water. Issues related to disposal and uses of by-product water from coalbed methane production have developed, in part, due to uncertainties in hydrologic properties. One hydrologic property of primary interest is the amount of water contained in Tertiary and upper Cretaceous hydrogeologic units in the Powder River Basin. The U.S. Geological Survey, in cooperation with the Bureau of Land Management, conducted a study to describe the hydrogeologic framework and to estimate ground-water volumes in different facies of Tertiary and upper Cretaceous hydrogeologic units in the Powder River Basin in Wyoming. A geographic information system was used to compile and utilize hydrogeologic maps, to describe the hydrogeologic framework, and to estimate the volume of ground water in Tertiary and upper Cretaceous hydrogeologic units in the Powder River structural basin in Wyoming. Maps of the altitudes of potentiometric surfaces, altitudes of the tops and bottoms of hydrogeologic units, thicknesses of hydrogeologic units, percent sand of hydrogeologic units, and outcrop boundaries for the following hydrogeologic units were used: Tongue River-Wasatch aquifer, Lebo confining unit, Tullock aquifer, Upper Hell Creek confining unit, and the Fox Hills-Lower Hell Creek aquifer. Literature porosity values of 30 percent for sand and 35 percent for non-sand facies were used to calculate the volume of total ground water in each hydrogeologic unit. Literature specific yield values of 26 percent for sand and 10 percent for non-sand facies, and literature specific storage values of 0.0001 ft-1 (1/foot) for sand facies and 0.00001 ft-1 for non-sand facies, were used to calculate a second volume of ground water for each hydrogeologic unit. Significant figure considerations limited estimates of ground-water volumes to two significant digits. A total ground-water volume of 2.0x1014 ft3 (cubic feet) was calculated using porosity values, and a total ground-water volume of 3.6x1013 ft3 was calculated using specific yield and specific storage values. These results are consistent with retention properties, which would have some of the total water being retained in the sediments. Sensitivity analysis shows that the estimates of ground-water volume are most sensitive to porosity. The estimates also are sensitive to confined thickness and saturated thickness. Better spatial information for hydrogeologic units could help refine the ground-water volume estimates.
Specific Language Impairments in Children.
ERIC Educational Resources Information Center
Watkins, Ruth V., Ed.; Rice, Mabel L., Ed.
The fourth volume in a series on communication and language intervention focuses on specific language impairments in children, and contains papers presented at a 1992 conference. Papers include the following: "Specific Language Impairments in Children: An Introduction" (Ruth V. Watkins); "Studies of Genetics of Specific Language Impairment" (J.…
Glass Transition Temperature- and Specific Volume- Composition Models for Tellurite Glasses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riley, Brian J.; Vienna, John D.
This report provides models for predicting composition-properties for tellurite glasses, namely specific gravity and glass transition temperature. Included are the partial specific coefficients for each model, the component validity ranges, and model fit parameters.
Volumetric measurement of tank volume
NASA Technical Reports Server (NTRS)
Walter, Richard T. (Inventor); Vanbuskirk, Paul D. (Inventor); Weber, William F. (Inventor); Froebel, Richard C. (Inventor)
1991-01-01
A method is disclosed for determining the volume of compressible gas in a system including incompressible substances in a zero-gravity environment consisting of measuring the change in pressure (delta P) for a known volume change rate (delta V/delta t) in the polytrophic region between isothermal and adiabatic conditions. The measurements are utilized in an idealized formula for determining the change in isothermal pressure (delta P sub iso) for the gas. From the isothermal pressure change (delta iso) the gas volume is obtained. The method is also applicable to determination of gas volume by utilizing work (W) in the compression process. In a passive system, the relationship of specific densities can be obtained.
Chapdelaine, Isabelle; de Roij van Zuijdewijn, Camiel L.M.; Mostovaya, Ira M.; Lévesque, Renée; Davenport, Andrew; Blankestijn, Peter J.; Wanner, Christoph; Nubé, Menso J.; Grooteman, Muriel P.C.
2015-01-01
In post-dilution online haemodiafiltration (ol-HDF), a relationship has been demonstrated between the magnitude of the convection volume and survival. However, to achieve high convection volumes (>22 L per session) detailed notion of its determining factors is highly desirable. This manuscript summarizes practical problems and pitfalls that were encountered during the quest for high convection volumes. Specifically, it addresses issues such as type of vascular access, needles, blood flow rate, recirculation, filtration fraction, anticoagulation and dialysers. Finally, five of the main HDF systems in Europe are briefly described as far as HDF prescription and optimization of the convection volume is concerned. PMID:25815176
NASA Technical Reports Server (NTRS)
Jester, Peggy L.; Lee, Jeffrey; Zukor, Dorothy J. (Technical Monitor)
2001-01-01
This document addresses the software requirements of the Geoscience Laser Altimeter System (GLAS) Standard Data Software (SDS) supporting the GLAS instrument on the EOS ICESat Spacecraft. This Software Requirements Document represents the initial collection of the technical engineering information for the GLAS SDS. This information is detailed within the second of four main volumes of the Standard documentation, the Product Specification volume. This document is a "roll-out" from the governing volume outline containing the Concept and Requirements sections.
An Evaluation of Public Preferences for Superfund Site Cleanup, Volume II: Pilot Study (1995)
In volume II, the authors present the detailed technical results of a pilot market research study that was conducted to determine preferences for the specific type and level of cleanup desired by the public at Superfund sites.
DOT National Transportation Integrated Search
2012-03-01
NJDOT has adopted AASHTO Guide Specifications for LRFD Seismic Bridge Design approved by the Highway : Subcommittee on Bridges and Structures in 2007. The main objective of research presented in this report has : been to resolve following issue...
A Pediatric Twin Study of Brain Morphometry
ERIC Educational Resources Information Center
Wallace, Gregory L.; Schmitt, J. Eric; Lenroot, Rhoshel; Viding, Essi; Ordaz, Sarah; Rosenthal, Michael A.; Molloy, Elizabeth A.; Clasen, Liv S.; Kendler, Kenneth S.; Neale, Michael C.; Giedd, Jay N.
2006-01-01
Background: Longitudinal pediatric neuroimaging studies have demonstrated increasing volumes of white matter and regionally-specific inverted U shaped developmental trajectories of gray matter volumes during childhood and adolescence. Studies of monozygotic and dyzygotic twins during this developmental period allow exploration of genetic and…
DOT National Transportation Integrated Search
1993-03-01
This report is the third of four volumes concerned with developing safety guidelines and specifications for high-speed : guided ground transportation (HSGGT) collision avoidance and accident survivability. The overall approach taken in : this study i...
Detection of EEG electrodes in brain volumes.
Graffigna, Juan P; Gómez, M Eugenia; Bustos, José J
2010-01-01
This paper presents a method to detect 128 EEG electrodes in image study and to merge with the Nuclear Magnetic Resonance volume for better diagnosis. First we propose three hypotheses to define a specific acquisition protocol in order to recognize the electrodes and to avoid distortions in the image. In the second instance we describe a method for segmenting the electrodes. Finally, registration is performed between volume of the electrodes and NMR.
Army Command and Control Study-82 (ACCS-82). Volume III. Annexes.
1979-09-30
specific issues identified by the group as requiring resolution in order to acompLish the study objective (Vol I, Chap 7). Recommendations are organized...Volume I, have been approved with the following modifications: a. Organizational Issue 1. The Army Readiness and Mobilization Region concept, described...in Volume IV, is the approved organizational alternative. b. Organizational Issue 3. The activation of one additional CONUS headquarters is
Survey of United States Army Reserve (USAR) Troop Program Unit (TPU) soldiers - 1989
1989-09-30
TABULATION VOLUMES This material provides information for use by readers to interpret the tabulation volumes accompanying the final project report...questionnaire responses of the junior enlisted "stayers" who were used as the sample to generate the first longitudinal Tabulation Volume. Comparing...crossed by Iselected demographic variables (as described below). Detailed below are the specific crossing variables used for the cross-sectional and
ERIC Educational Resources Information Center
Yokelson, Doris, Ed.
Volume 3 of a four volume collection, this document addresses the extent and the depth of public support in America for domestic social welfare programs and the social, moral, and economic attitudes of the poor and near poor. Specifically, three major sections focus on: the national morale and support for domestic reform; attitudes toward welfare,…
Recovery of Navy distillate fuel from reclaimed product. Volume II. Literature review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brinkman, D.W.; Whisman, M.L.
In an effort to assist the Navy to better utilize its waste hydrocarbons, NIPER, with support from the US Department of Energy, is conducting research designed to ultimately develop a practical technique for converting Reclaimed Product (RP) into specification Naval Distillate Fuel (F-76). This first phase of the project was focused on reviewing the literature and available information from equipment manufacturers. The literature survey has been carefully culled for methodology applicable to the conversion of RP into diesel fuel suitable for Navy use. Based upon the results of this study, a second phase has been developed and outlined in whichmore » experiments will be performed to determine the most practical recycling technologies. It is realized that the final selection of one particular technology may be site-specific due to vast differences in RP volume and available facilities. A final phase, if funded, would involve full-scale testing of one of the recommended techniques at a refueling depot. The Phase I investigations are published in two volumes. Volume 1, Technical Discussion, includes the narrative and Appendices I and II. Appendix III, a detailed Literature Review, includes both a narrative portion and an annotated bibliography containing about 800 references and abstracts. This appendix, because of its volume, has been published separately as Volume 2.« less
Häckel, M; Hinz, H J; Hedwig, G R
1999-11-15
The partial molar volumes of tripeptides of sequence glycyl-X-glycine, where X is one of the amino acids alanine, leucine, threonine, glutamine, phenylalanine, histidine, cysteine, proline, glutamic acid, and arginine, have been determined in aqueous solution over the temperature range 10-90 degrees C using differential scanning densitometry . These data, together with those reported previously, have been used to derive the partial molar volumes of the side-chains of all 20 amino acids. The side-chain volumes are critically compared with literature values derived using partial molar volumes for alternative model compounds. The new amino acid side-chain volumes, along with that for the backbone glycyl group, were used to calculate the partial specific volumes of several proteins in aqueous solution. The results obtained are compared with those observed experimentally. The new side-chain volumes have also been used to re-determine residue volume changes upon protein folding.
Returns to scientific publications for pharmaceutical products in the United States.
Slejko, Julia F; Basu, Anirban; Sullivan, Sean D
2018-02-01
Drug-specific clinical and health economic and outcomes research (HEOR) publications have amassed, but their effect on drug sales is largely unknown. We estimated the impact of publications on pharmaceutical sales in 3 markets (statins, rheumatoid arthritis, and asthma drugs) with varying generic competition. An event-study approach with fixed effects and difference-in-fixed-effects modeling was used to estimate the causal effects of drug-specific publications on subsequent quarter's drug-specific sales and volume. High-impact clinical and HEOR publications have significant positive effects on sales (mediated through price) and volume in the statin market (high generic competition). High-impact clinical publications have a significant positive effect on sales (mediated through volume) in low-generic competition market (asthma). The effects of publications in the rheumatoid arthritis market (no generic competition) on sales were null. Manufacturers' investment in clinical and HEOR publications needs to be strategic and should be anticipated and complemented by public investments in such studies. Copyright © 2017 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Roquet, F.; Madec, G.; McDougall, Trevor J.; Barker, Paul M.
2015-06-01
A new set of approximations to the standard TEOS-10 equation of state are presented. These follow a polynomial form, making it computationally efficient for use in numerical ocean models. Two versions are provided, the first being a fit of density for Boussinesq ocean models, and the second fitting specific volume which is more suitable for compressible models. Both versions are given as the sum of a vertical reference profile (6th-order polynomial) and an anomaly (52-term polynomial, cubic in pressure), with relative errors of ∼0.1% on the thermal expansion coefficients. A 75-term polynomial expression is also presented for computing specific volume, with a better accuracy than the existing TEOS-10 48-term rational approximation, especially regarding the sound speed, and it is suggested that this expression represents a valuable approximation of the TEOS-10 equation of state for hydrographic data analysis. In the last section, practical aspects about the implementation of TEOS-10 in ocean models are discussed.
Moon, Chan Hong; Fukuda, Mitsuhiro; Kim, Seong-Gi
2012-01-01
The neural specificity of hemodynamic-based functional magnetic resonance imaging (fMRI) signals are dependent on both the vascular regulation and the sensitivity of the applied fMRI technique to different types and sizes of blood vessels. In order to examine the specificity of MRI-detectable hemodynamic responses, submillimeter blood oxygenation-level dependent (BOLD) and cerebral blood volume (CBV) fMRI studies were performed in a well-established cat orientation column model at 9.4 Tesla. Neural-nonspecific and -specific signals were separated by comparing the fMRI responses of orthogonal orientation stimuli. The BOLD response was dominantly neural-nonspecific, mostly originating from pial and intracortical emerging veins, and thus was highly correlated with baseline blood volume. Uneven baseline CBV may displace or distort small functional domains in high-resolution BOLD maps. The CBV response in the parenchyma exhibited dual spatiotemporal characteristics, a fast and early neural-nonspecific response (with 4.3-s time constant) and a slightly slower and delayed neural-specific response (with 9.4-s time constant). The nonspecific CBV signal originates from early-responding arteries and arterioles, while the specific CBV response, which is not correlated with baseline blood volume, arises from late-responding microvessels including small pre-capillary arterioles and capillaries. Our data indicate that although the neural specificity of CBV fMRI signals is dependent on stimulation duration, high-resolution functional maps can be obtained from steady-state CBV studies. PMID:22960251
Radwaste desk reference - Volume 3, Part 1: Processing liquid waste. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deltete, D.; Fisher, S.; Kelly, J.J.
1994-05-01
EPRI began, late in 1987, to produce a Radwaste Desk Reference that would allow each of the member utilities access to the available information and expertise on radwaste management. EPRI considers this important because radwaste management involves a wide variety of scientific and engineering disciplines. These include chemical and mechanical engineering, chemistry, and health physics. Radwaste management also plays a role in implementing a wide variety of regulatory requirements. These include plant-specific technical specifications, NRC standards for protection against radiation, DOE transportation regulations and major environmental legislation such as the Resource Conservation and Recovery Act. EPRI chose a question andmore » answer format because it could be easily accessed by radwaste professionals with a variety of interests. The questions were generated at two meetings of utility radwaste professionals and EPRI contractors. The names of the participants and their affiliation appear in the acknowledgments. The questions were organized using the matrix which appears in the introduction and below. During the writing phase, some questions were combined and new questions added. To aid the reader, each question was numbered and tied to individual Section Contents. An extensive index provides additional reader assistance. EPRI chose authors who are acknowledged experts in their fields and good communicators. Each author focused her or his energies on specific areas of radwaste management activities, thereby contributing to one or more volumes of the Radwaste Desk Reference. Volume 1, which is already in publication, addresses dry active waste generation, processing and measurement. Volume 2 addresses low level waste storage, transportation and disposal. This volume, Volume 3, is being issued in two parts. Part 1 concentrates on the processing of liquid radioactive waste, whereas Part 2 addresses liquid waste management.« less
Multiloop integral system test (MIST): Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gloudemans, J.R.
1991-04-01
The Multiloop Integral System Test (MIST) is part of a multiphase program started in 1983 to address small-break loss-of-coolant accidents (SBLOCAs) specific to Babcock and Wilcox designed plants. MIST is sponsored by the US Nuclear Regulatory Commission, the Babcock Wilcox Owners Group, the Electric Power Research Institute, and Babcock and Wilcox. The unique features of the Babcock and Wilcox design, specifically the hot leg U-bends and steam generators, prevented the use of existing integral system data or existing integral facilities to address the thermal-hydraulic SBLOCA questions. MIST was specifically designed and constructed for this program, and an existing facility --more » the Once Through Integral System (OTIS) -- was also used. Data from MIST and OTIS are used to benchmark the adequacy of system codes, such as RELAP5 and TRAC, for predicting abnormal plant transients. The MIST program is reported in 11 volumes. Volumes 2 through 8 pertain to groups of Phase 3 tests by type; Volume 9 presents inter-group comparisons; Volume 10 provides comparisons between the RELAP5/MOD2 calculations and MIST observations, and Volume 11 (with addendum) presents the later Phase 4 tests. This is Volume 1 of the MIST final report, a summary of the entire MIST program. Major topics include, Test Advisory Group (TAG) issues, facility scaling and design, test matrix, observations, comparison of RELAP5 calculations to MIST observations, and MIST versus the TAG issues. MIST generated consistent integral-system data covering a wide range of transient interactions. MIST provided insight into integral system behavior and assisted the code effort. The MIST observations addressed each of the TAG issues. 11 refs., 29 figs., 9 tabs.« less
Poster - Thur Eve - 54: A software solution for ongoing DVH quality assurance in radiation therapy.
Annis, S-L; Zeng, G; Wu, X; Macpherson, M
2012-07-01
A program has been developed in MATLAB for use in quality assurance of treatment planning of radiation therapy. It analyzes patient DVH files and compiles dose volume data for review, trending, comparison and analysis. Patient DVH files are exported from the Eclipse treatment planning system and saved according to treatment sites and date. Currently analysis is available for 4 treatment sites; Prostate, Prostate Bed, Lung, and Upper GI, with two functions for data report and analysis: patient-specific and organ-specific. The patient-specific function loads one patient DVH file and reports the user-specified dose volume data of organs and targets. These data can be compiled to an external file for a third party analysis. The organ-specific function extracts a requested dose volume of an organ from the DVH files of a patient group and reports the statistics over this population. A graphical user interface is utilized to select clinical sites, function and structures, and input user's requests. We have implemented this program in planning quality assurance at our center. The program has tracked the dosimetric improvement in GU sites after VMAT was implemented clinically. It has generated dose volume statistics for different groups of patients associated with technique or time range. This program allows reporting and statistical analysis of DVH files. It is an efficient tool for the planning quality control in radiation therapy. © 2012 American Association of Physicists in Medicine.
PDLE: Extending Provisional Contributions. Volume 2
ERIC Educational Resources Information Center
Murphey, Tim, Ed.
2003-01-01
Focusing on midcareer professionals, this second volume includes descriptive accounts of professional development opportunities designed specifically so that language teachers can reinvigorate their teaching and remain on the path of lifelong learning. Due to the amount of development that comes from collaboration with other professionals, this…
DOT National Transportation Integrated Search
1993-03-01
This report is the third of four volumes concerned with developing safety guidelines and specifications for high-speed guided ground transportation (HSGGT) collision avoidance and accident survivability. The overall approach taken in this study is to...
DOT National Transportation Integrated Search
1993-03-01
This report is the first of four volumes concerned with developing safety guidelines and specifications for high-speed guided ground transportation (HSGGT) collision avoidance and accident survivability. The overall approach taken in this study is to...
Chemical measurement of urine volume
NASA Technical Reports Server (NTRS)
Sauer, R. L.
1978-01-01
Chemical method of measuring volume of urine samples using lithium chloride dilution technique, does not interfere with analysis, is faster, and more accurate than standard volumetric of specific gravity/weight techniques. Adaptation of procedure to urinalysis could prove generally practical for hospital mineral balance and catechoamine determinations.
DOT National Transportation Integrated Search
1993-03-01
This report is the second of four volumes concerned with developing safety guidelines and specifications for high-speed guided ground transportation (HSGGT) collision avoidance and accident survivability. The overall approach taken in this study is t...
Graham, James E.; Deutsch, Anne; O’Connell, Ann A.; Karmarkar, Amol M.; Granger, Carl V.; Ottenbacher, Kenneth J.
2013-01-01
Background It is unclear if volume-outcome relationships exist in inpatient rehabilitation. Objectives Assess associations between facility volumes and two patient-centered outcomes in the three most common diagnostic groups in inpatient rehabilitation. Research Design We used hierarchical linear and generalized linear models to analyze administrative assessment data from patients receiving inpatient rehabilitation services for stroke (n=202,423), lower extremity fracture (n=132,194), or lower extremity joint replacement (n=148,068) between 2006 and 2008 in 717 rehabilitation facilities across the U.S. Facilities were assigned to quintiles based on average annual diagnosis-specific patient volumes. Measures Discharge functional status (FIM instrument) and probability of home discharge. Results Facility-level factors accounted for 6–15% of the variance in discharge FIM total scores and 3–5% of the variance in home discharge probability across the 3 diagnostic groups. We used the middle volume quintile (Q3) as the reference group for all analyses and detected small, but statistically significant (p < .01) associations with discharge functional status in all three diagnosis groups. Only the highest volume quintile (Q5) reached statistical significance, displaying higher functional status ratings than Q3 each time. The largest effect was observed in FIM total scores among fracture patients, with only a 3.6-point difference in Q5 and Q3 group means. Volume was not independently related to home discharge. Conclusions Outcome-specific volume effects ranged from small (functional status) to none (home discharge) in all three diagnostic groups. Patients with these conditions can be treated locally rather than at higher-volume regional centers. Further regionalization of inpatient rehabilitation services is not needed for these conditions. PMID:23579350
Graham, James E; Deutsch, Anne; O'Connell, Ann A; Karmarkar, Amol M; Granger, Carl V; Ottenbacher, Kenneth J
2013-05-01
It is unclear if volume-outcome relationships exist in inpatient rehabilitation. Assess associations between facility volumes and 2 patient-centered outcomes in the 3 most common diagnostic groups in inpatient rehabilitation. We used hierarchical linear and generalized linear models to analyze administrative assessment data from patients receiving inpatient rehabilitation services for stroke (n=202,423), lower extremity fracture (n=132,194), or lower extremity joint replacement (n=148,068) between 2006 and 2008 in 717 rehabilitation facilities across the United States. Facilities were assigned to quintiles based on average annual diagnosis-specific patient volumes. Discharge functional status (FIM instrument) and probability of home discharge. Facility-level factors accounted for 6%-15% of the variance in discharge FIM total scores and 3%-5% of the variance in home discharge probability across the 3 diagnostic groups. We used the middle volume quintile (Q3) as the reference group for all analyses and detected small, but statistically significant (P<0.01) associations with discharge functional status in all 3 diagnosis groups. Only the highest volume quintile (Q5) reached statistical significance, displaying higher functional status ratings than Q3 each time. The largest effect was observed in FIM total scores among fracture patients, with only a 3.6-point difference in Q5 and Q3 group means. Volume was not independently related to home discharge. Outcome-specific volume effects ranged from small (functional status) to none (home discharge) in all 3 diagnostic groups. Patients with these conditions can be treated locally rather than at higher volume regional centers. Further regionalization of inpatient rehabilitation services is not needed for these conditions.
Understanding Skill in EVA Mass Handling. Volume 2; Empirical Investigation
NASA Technical Reports Server (NTRS)
Riccio, Gary; McDonald, Vernon; Peters, Brian; Layne, Charles; Bloomberg, Jacob
1997-01-01
In this report we describe the details of our empirical protocol effort investigating skill in extravehicular mass handling using NASA's principal mass handling simulator, the precision air bearing floor. Contents of this report include a description of the necessary modifications to the mass handling simulator; choice of task, and the description of an operationally relevant protocol. Our independent variables are presented in the context of the specific operational issues they were designed to simulate. The explanation of our dependent variables focuses on the specific data processing procedures used to transform data from common laboratory instruments into measures that are relevant to a special class of nested control systems (discussed in Volume 1): manual interactions between an individual and the substantial environment. The data reduction is explained in the context of the theoretical foundation described in Volume 1. Finally as a preface to the presentation of the empirical data in Volume 3 of this report series, a set of detailed hypotheses is presented.
[Preoperative imaging/operation planning for liver surgery].
Schoening, W N; Denecke, T; Neumann, U P
2015-12-01
The currently established standard for planning liver surgery is multistage contrast media-enhanced multidetector computed tomography (CM-CT), which as a rule enables an appropriate resection planning, e.g. a precise identification and localization of primary and secondary liver tumors as well as the anatomical relation to extrahepatic and/or intrahepatic vascular and biliary structures. Furthermore, CM-CT enables the measurement of tumor volume, total liver volume and residual liver volume after resection. Under the condition of normal liver function a residual liver volume of 25 % is nowadays considered sufficient and safe. Recent studies in patients with liver metastases of colorectal cancer showed a clear staging advantage of contrast media-enhanced magnetic resonance imaging (CM-MRI) versus CM-CT. In addition, most recent data showed that the use of liver-specific MRI contrast media further increases the sensitivity and specificity of detection of liver metastases. This imaging technology seems to lead closer to the ideal "one stop shopping" diagnostic tool in preoperative planning of liver resection.
Brain volume change and cognitive trajectories in aging.
Fletcher, Evan; Gavett, Brandon; Harvey, Danielle; Farias, Sarah Tomaszewski; Olichney, John; Beckett, Laurel; DeCarli, Charles; Mungas, Dan
2018-05-01
Examine how longitudinal cognitive trajectories relate to brain baseline measures and change in lobar volumes in a racially/ethnically and cognitively diverse sample of older adults. Participants were 460 older adults enrolled in a longitudinal aging study. Cognitive outcomes were measures of episodic memory, semantic memory, executive function, and spatial ability derived from the Spanish and English Neuropsychological Assessment Scales (SENAS). Latent variable multilevel modeling of the four cognitive outcomes as parallel longitudinal processes identified intercepts for each outcome and a second order global change factor explaining covariance among the highly correlated slopes. We examined how baseline brain volumes (lobar gray matter, hippocampus, and white matter hyperintensity) and change in brain volumes (lobar gray matter) were associated with cognitive intercepts and global cognitive change. Lobar volumes were dissociated into global and specific components using latent variable methods. Cognitive change was most strongly associated with brain gray matter volume change, with strong independent effects of global gray matter change and specific temporal lobe gray matter change. Baseline white matter hyperintensity and hippocampal volumes had significant incremental effects on cognitive decline beyond gray matter change. Baseline lobar gray matter was related to cognitive decline, but did not contribute beyond gray matter change. Cognitive decline was strongly influenced by gray matter volume change and, especially, temporal lobe change. The strong influence of temporal lobe gray matter change on cognitive decline may reflect involvement of temporal lobe structures that are critical for late life cognitive health but also are vulnerable to diseases of aging. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Correlation between remnant inferior turbinate volume and symptom severity of empty nose syndrome.
Hong, Hye Ran; Jang, Yong Ju
2016-06-01
Empty nose syndrome (ENS) is an iatrogenic disorder caused by turbinate reduction procedures, which results in considerable nasal dysfunction and severely impaired quality of life. However, there is a lack of data that explains the relationship between the degree of turbinate reduction and subjective symptoms. The aim of this study was to evaluate the effects of remnant inferior turbinate volume on symptom severity. We retrospectively analyzed data from 34 patients who were diagnosed with ENS. All patients underwent computed tomography scanning and completed the SNOT-25 questionnaire. The control group consisted of 10 patients with pituitary adenoma who did not have any sinonasal symptoms or abnormalities. The inferior turbinate volumes were compared between groups, and the correlation between inferior turbinate volumes (ITVs) and Sino-Nasal Outcome Test-25 (SNOT-25) was also evaluated. The ENS group presented with a significantly smaller inferior turbinate volume than the control group (P < 0.001). The overall SNOT-25 score demonstrated no statistically significant correlation with anterior, posterior, or total ITV (P > 0.05, respectively). Among the various items on SNOT-25, a high dryness score was significantly correlated with a smaller total inferior turbinate volume (P = 0.030). Facial pain was significantly correlated with smaller anterior ITV (P = 0.011). In addition, patients who had smaller posterior inferior turbinate volume demonstrated higher scores on specific SNOT-25 items. A smaller inferior turbinate volume is significantly associated with specific SNOT-25 items in ENS patients. 4. Laryngoscope, 126:1290-1295, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
Energy consumption of agitators in activated sludge tanks - actual state and optimization potential.
Füreder, K; Svardal, K; Frey, W; Kroiss, H; Krampe, J
2018-02-01
Depending on design capacity, agitators consume about 5 to 20% of the total energy consumption of a wastewater treatment plant. Based on inhabitant-specific energy consumption (kWh PE 120 -1 a -1 ; PE 120 is population equivalent, assuming 120 g chemical oxygen demand per PE per day), power density (W m -3 ) and volume-specific energy consumption (Wh m -3 d -1 ) as evaluation indicators, this paper provides a sound contribution to understanding energy consumption and energy optimization potentials of agitators. Basically, there are two ways to optimize agitator operation: the reduction of the power density and the reduction of the daily operating time. Energy saving options range from continuous mixing with low power densities of 1 W m -3 to mixing by means of short, intense energy pulses (impulse aeration, impulse stirring). However, the following correlation applies: the shorter the duration of energy input, the higher the power density on the respective volume-specific energy consumption isoline. Under favourable conditions with respect to tank volume, tank geometry, aeration and agitator position, mixing energy can be reduced to 24 Wh m -3 d -1 and below. Additionally, it could be verified that power density of agitators stands in inverse relation to tank volume.
Site-specific thromboembolism: a novel animal model for stroke.
Ringer, Andrew J; Guterman, Lee R; Hopkins, L Nelson
2004-02-01
To develop a technique for site-specific placement of a thrombus of predetermined volume in an animal model for the purpose of evaluating methods of intravascular thrombolysis and clot retrieval. Six swine were subjected to thrombus injection bilaterally in the ascending pharyngeal artery (APA). Each animal underwent transfemoral angiography while under general anesthesia. A nondetachable balloon catheter and a 3-French microcatheter were then advanced into the common carotid artery through a 7-French guide catheter. With the microcatheter in the proximal APA and the balloon inflated proximally, a bolus of preformed thrombus composed of 0.9 mL of autologous blood and 0.1 mL of bovine thrombin (200 IU/mL) was injected through the microcatheter while local flow arrest was maintained for 15 min. The balloon was deflated and removed. The occluded arteries were observed by serial angiography for 3 hr and then resected for gross examination and hematoxylin and eosin staining. Each APA was occluded angiographically and did not recanalize during the 3-hr observation period. Persistent, proximal progression of thrombus to the superior thyroid artery origin occurred in three animals. Gross inspection revealed that the resected arteries contained thrombus in the proximal APA but not in the common carotid artery. Histologic examination revealed organized thrombus, without evidence of intimal injury. Our model provides a simple, reliable method for site-specific injection of a thrombus of predetermined volume. Site-specific placement is important for evaluation of the efficacy of thrombolytic agents and techniques. Angiographic evidence of brain revascularization can be used to grade revascularization and clot volume. The ability to specifically localize and estimate clot volume makes our model well suited for the evaluation and comparison of thrombolytic agents and endovascular techniques.
Helicity is the only integral invariant of volume-preserving transformations
Enciso, Alberto; Peralta-Salas, Daniel; de Lizaur, Francisco Torres
2016-01-01
We prove that any regular integral invariant of volume-preserving transformations is equivalent to the helicity. Specifically, given a functional ℐ defined on exact divergence-free vector fields of class C1 on a compact 3-manifold that is associated with a well-behaved integral kernel, we prove that ℐ is invariant under arbitrary volume-preserving diffeomorphisms if and only if it is a function of the helicity. PMID:26864201
2016-07-01
Predicted variation in (a) hot-spot number density , (b) hot-spot volume fraction, and (c) hot-spot specific surface area for each ensemble with piston speed...packing density , characterized by its effective solid volume fraction φs,0, affects hot-spot statistics for pressure dominated waves corresponding to...distribution in solid volume fraction within each ensemble was nearly Gaussian, and its standard deviation decreased with increasing density . Analysis of
Girbau-Massana, Dolors; Garcia-Marti, Gracian; Marti-Bonmati, Luis; Schwartz, Richard G
2014-04-01
We studied gray-white matter and cerebrospinal fluid (CSF) alterations that may be critical for language, through an optimized voxel-based morphometry evaluation in children with Specific Language Impairment (SLI), compared to Typical Language Development (TLD). Ten children with SLI (8;5-10;9) and 14 children with TLD (8;2-11;8) participated. They received a comprehensive language and reading test battery. We also analyzed a subgroup of six children with SLI+RD (Reading Disability). Brain images from 3-Tesla MRIs were analyzed with intelligence, age, gender, and total intracranial volume as covariates. Children with SLI or SLI+RD exhibited a significant lower overall gray matter volume than children with TLD. Particularly, children with SLI showed a significantly lower volume of gray matter compared to children with TLD in the right postcentral parietal gyrus (BA4), and left and right medial occipital gyri (BA19). The group with SLI also exhibited a significantly greater volume of gray matter in the right superior occipital gyrus (BA19), which may reflect a brain reorganization to compensate for their lower volumes at medial occipital gyri. Children with SLI+RD, compared to children with TLD, showed a significantly lower volume of: (a) gray matter in the right postcentral parietal gyrus; and (b) white matter in the right inferior longitudinal fasciculus (RILF), which interconnects the temporal and occipital lobes. Children with TLD exhibited a significantly lower CSF volume than children with SLI and children with SLI+RD respectively, who had somewhat smaller volumes of gray matter allowing for more CSF volume. The significant lower gray matter volume at the right postcentral parietal gyrus and greater cerebrospinal fluid volume may prove to be unique markers for SLI. We discuss the association of poor knowledge/visual representations and language input to brain development. Our comorbid study showed that a significant lower volume of white matter in the right inferior longitudinal fasciculus may be unique to children with SLI and Reading Disability. It was significantly associated to reading comprehension of sentences and receptive language composite z-score, especially receptive vocabulary and oral comprehension of stories. Copyright © 2014 Elsevier Ltd. All rights reserved.
Investigation of brain structure in the 1-month infant.
Dean, Douglas C; Planalp, E M; Wooten, W; Schmidt, C K; Kecskemeti, S R; Frye, C; Schmidt, N L; Goldsmith, H H; Alexander, A L; Davidson, R J
2018-05-01
The developing brain undergoes systematic changes that occur at successive stages of maturation. Deviations from the typical neurodevelopmental trajectory are hypothesized to underlie many early childhood disorders; thus, characterizing the earliest patterns of normative brain development is essential. Recent neuroimaging research provides insight into brain structure during late childhood and adolescence; however, few studies have examined the infant brain, particularly in infants under 3 months of age. Using high-resolution structural MRI, we measured subcortical gray and white matter brain volumes in a cohort (N = 143) of 1-month infants and examined characteristics of these volumetric measures throughout this early period of neurodevelopment. We show that brain volumes undergo age-related changes during the first month of life, with the corresponding patterns of regional asymmetry and sexual dimorphism. Specifically, males have larger total brain volume and volumes differ by sex in regionally specific brain regions, after correcting for total brain volume. Consistent with findings from studies of later childhood and adolescence, subcortical regions appear more rightward asymmetric. Neither sex differences nor regional asymmetries changed with gestation-corrected age. Our results complement a growing body of work investigating the earliest neurobiological changes associated with development and suggest that asymmetry and sexual dimorphism are present at birth.
MOD-5A wind turbine generator program design report: Volume 1: Executive Summary
NASA Technical Reports Server (NTRS)
1984-01-01
The design, development and analysis of the 7.3 MW MOD-5A wind turbine generator covering work performed between July 1980 and June 1984 is discussed. The report is divided into four volumes: Volume 1 summarizes the entire MOD-5A program, Volume 2 discusses the conceptual and preliminary design phases, Volume 3 describes the final design of the MOD-5A, and Volume 4 contains the drawings and specifications developed for the final design. Volume 1, the Executive Summary, summarizes all phases of the MOD-5A program. The performance and cost of energy generated by the MOD-5A are presented. Each subsystem - the rotor, drivetrain, nacelle, tower and foundation, power generation, and control and instrumentation subsystems - is described briefly. The early phases of the MOD-5A program, during which the design was analyzed and optimized, and new technologies and materials were developed, are discussed. Manufacturing, quality assurance, and safety plans are presented. The volume concludes with an index of volumes 2 and 3.
Occupational Information 1990/91. Volume II.
ERIC Educational Resources Information Center
Nebraska Univ., Lincoln. Nebraska Career Information System.
The Nebraska Occupational Information books (volumes I and II) contain information about 386 different occupations in the state and answer questions about specific occupations in detail. The descriptions are arranged according to a U.S. Department of Labor classification system, with occupational titles clustered in general groups of selected…
DOT National Transportation Integrated Search
1980-06-01
Volume 3 contains the application of the three-dimensional (3-D) finite element program, Automatic Dynamic Incremental Nonlinear Analysis (ADINA), which was designed to replace the traditional 2-D plane strain analysis, to a specific location. The lo...
Nineteenth International Cosmic Ray Conference. HE Sessions, Volume 8
NASA Technical Reports Server (NTRS)
Jones, F. C. (Compiler)
1985-01-01
Papers submitted for presentation at the 19th International Cosmic Ray Conference are compiled. The present volume contains papers addressing high energy interactions and related phenomena. Specific topic areas include muons, neutrinos, magnetic monopoles, nucleon decay, searches for new particles, and acoustic and thermoluminescence detection techniques.
Occupational Information 1990/91. Volume I.
ERIC Educational Resources Information Center
Nebraska Univ., Lincoln. Nebraska Career Information System.
The Nebraska Occupational Information books (volumes I and II) contain information about 386 different occupations in the state and answer questions about specific occupations in detail. The descriptions are arranged according to a U.S. Department of Labor classification system, with occupational titles clustered in general groups of selected…
DOT National Transportation Integrated Search
1979-09-01
Volume 1 of Theoretical Studies of Microstrip Antennas deals with general techniques and analyses of single and coupled radiating elements. Specifically, we review and then employ an important equivalence theorem that allows a pair of vector potentia...
Density and Specific Gravity Metrics in Biomass Research
Micheal C. Wiemann; G. Bruce Williamson
2012-01-01
Following the 2010 publication of Measuring Wood Specific Gravity⦠Correctly in the American Journal of Botany, readers contacted us to inquire about application of wood density and specific gravity to biomass research. Here we recommend methods for sample collection, volume measurement, and determination of wood density and specific gravity for...
Some Mechanical and Ballistic Properties of Titanium and Titanium Alloys
1950-03-07
treated alloy steel armor, Justifies high expectations that titanium alloys may make excellent armor meterials . The corrosion resistant properties of...Fur* Metal Beat Treated -7-4 - -I-re Tensile Strength in pot 13,000 5 0,oo 230,000 203400 speifict Gravity 2.71 7.87 4.54 2.9 7.9 4.6 Stroe4cth-Vleight...solution of HCI: 50 parts by volume ECl-specific gravity 1.19 (37.6%) 50 parts by volume H2 0 2. Concentrated RIP: Hl-specific gravity 1.15 (14%) 3. 5
Subcortical intelligence: caudate volume predicts IQ in healthy adults.
Grazioplene, Rachael G; G Ryman, Sephira; Gray, Jeremy R; Rustichini, Aldo; Jung, Rex E; DeYoung, Colin G
2015-04-01
This study examined the association between size of the caudate nuclei and intelligence. Based on the central role of the caudate in learning, as well as neuroimaging studies linking greater caudate volume to better attentional function, verbal ability, and dopamine receptor availability, we hypothesized the existence of a positive association between intelligence and caudate volume in three large independent samples of healthy adults (total N = 517). Regression of IQ onto bilateral caudate volume controlling for age, sex, and total brain volume indicated a significant positive correlation between caudate volume and intelligence, with a comparable magnitude of effect across each of the three samples. No other subcortical structures were independently associated with IQ, suggesting a specific biological link between caudate morphology and intelligence. © 2014 Wiley Periodicals, Inc.
Goh, Vicky; Halligan, Steve; Taylor, Stuart A; Burling, David; Bassett, Paul; Bartram, Clive I
2007-02-01
To determine whether computed tomographic (CT) perfusion measurements in prospectively recruited patients can be used to differentiate between diverticulitis and colorectal cancer and to compare this discrimination with that of standard morphologic criteria. After institutional review board approval and written informed consent were obtained, 60 patients (24 men, 36 women; mean age, 69 years; range, 33.5-90.4 years; 20 patients with cancer, 20 with diverticulitis, and 20 with inactive diverticular disease) underwent CT perfusion imaging at the level of the colonic abnormality, and perfusion parameters were calculated. Analysis of variance was used to investigate any differences in perfusion between the patient groups. Two independent observers also analyzed an abdominopelvic CT study obtained immediately after the CT perfusion study and noted standard morphologic criteria for differential diagnosis. The sensitivity and specificity of CT perfusion measurements for determining the diagnostic category were compared with morphologic criteria by means of multivariate analysis to identify the most discriminatory criteria. Mean blood volume, blood flow, transit time, and permeability were significantly different between patients with cancer and those with diverticulitis (P < .0001); patients with cancer had the highest blood volume, blood flow, and permeability and the shortest transit time. The most discriminatory criteria for determining diagnostic category were blood volume, transit time, permeability, and presence of pericolonic nodes (P = .05, .02, .04, and .02, respectively). Blood volume and blood flow each had a sensitivity of 80% and had specificity of 70% and 75%, respectively, for cancer in comparison with standard morphologic criteria: less than 5 cm of bowel involvement (45% sensitivity, 95% specificity), presence of a mass (85% sensitivity, 90% specificity), pericolonic inflammation (75% sensitivity, 5% specificity), and pericolonic nodes (90% sensitivity, 45% specificity). CT perfusion measurements enable differentiation and better discrimination, in comparison with morphologic criteria, between cancer and diverticulitis. (c) RSNA, 2007.
DOT National Transportation Integrated Search
1980-06-01
A specific goal of safety is to reduce the number of injuries that may result from the collision of two trains. In Volume IV, a computer code for the simulated crash of two railcar consists is described. The code is capable of simulating the mechanic...
Ninteenth International Cosmic Ray Conference. SH Sessions, Volume 4
NASA Technical Reports Server (NTRS)
Jones, F. C. (Compiler)
1985-01-01
Papers submitted for presentation at the 19th International Cosmic Ray Conference are compiled. This volume covers solar and heliospheric phenomena, specifically, particle acceleration; cosmic ray compsotion, spectra, and anisotropy; propagation of solar and interplanetary energetic particles; solar-cycle modulation; and propagation of galactic particles in the heliosphere.
The Education of African-Americans.
ERIC Educational Resources Information Center
Willie, Charles V., Ed.; And Others
The 17 papers in this volume are products of a study group on the education of African Americans that was part of a national project, "The Assessment of the Status of African-Americans." The volume takes a comprehensive look at the education of African Americans, specifically early childhood through postsecondary education, and relevant…
Trends in Higher Education. Volume 2: Faculty
ERIC Educational Resources Information Center
Association of Universities and Colleges of Canada, 2007
2007-01-01
This volume of "Trends" provides a historical analysis of faculty hiring over the last 30 years, with breakdowns that examine nationwide shifts in gender, age, mobility and attrition as well as within specific disciplines. Following this analysis is a discussion of the factors that will drive change in faculty renewal for the…
A DDC Bibliography on Computers in Information Sciences. Volume II. Information Sciences Series.
ERIC Educational Resources Information Center
Defense Documentation Center, Alexandria, VA.
The unclassified and unlimited bibliography compiles references dealing specifically with the role of computers in information sciences. The volume contains 239 annotated references grouped under three major headings: Artificial and Programming Languages, Computer Processing of Analog Data, and Computer Processing of Digital Data. The references…
Spotlight on Arts Education. Volume 3, Spring, 1988.
ERIC Educational Resources Information Center
North Carolina State Dept. of Public Instruction, Raleigh. Div. of Arts Education.
This volume focuses on four North Carolina school systems that have developed strategies for improving teaching and learning environments in arts education. Article 1 discusses the challenge of providing adequate levels of visual arts instruction for exceptional children in Dare County and describes a specific art project for handicapped students…
Responsibility: A Thematic Sequence of English Units.
ERIC Educational Resources Information Center
Institute for Services to Education, Inc., Washington, DC.
One of a series of volumes containing units on specific themes designed for use in college freshman English courses, this particular volume considers people and their responsibilities, through the use of recordings, cartoons, satire, modern and ancient drama, modern fiction, and contemporary essays. The sequence is divided into four sections.…
DISCUS Interactive System Users' Manual. Final Report.
ERIC Educational Resources Information Center
Silver, Steven S.; Meredith, Joseph C.
The results of the second 18 months (December 15, 1968-June 30, 1970) of effort toward developing an Information Processing Laboratory for research and education in library science is reported in six volumes. This volume contains: the basic on-line interchange, DISCUS operations, programming in DISCUS, concise DISCUS specifications, system author…
Advances in Environmental Science and Technology, Volume Two.
ERIC Educational Resources Information Center
Pitts, James N., Jr., Ed.; Metcalf, Robert L., Ed.
The aim of this volume is to help delineate and solve the multitude of environmental problems our technology has created. Representing a diversity of notable approaches to crucial environmental issues, it features eight self-contained chapters by noted scientists. Topics range from broad considerations of air pollution and specific techniques for…
Increased Rail Transit Vehicle Crashworthiness in Head-On Collisions. Volume II. Primary Collision.
DOT National Transportation Integrated Search
1980-06-01
A specific goal of safety is to reduce the number of injuries that may result from the collision of two trains. In Volume II, an analytical model in two dimensions, longitudinal and vertical, of the primary collision of two impacting urban railcar co...
Increased Rail Transit Vehicle Crashworthiness in Head-On Collisions. Volume I. Initial Impact.
DOT National Transportation Integrated Search
1980-06-01
A specific goal of safety is to reduce the number of injuries that may result from the collision of two trains. In Volume I, a two-dimensional analytic simulation model of the leading cars of two impacting transit car consists is formulated. This mod...
Rediscovering Black Women's Literature. Review Essay [Book Review].
ERIC Educational Resources Information Center
George, Hermon, Jr.
1992-01-01
These volumes offer a blend of genres, authors, and purposes. Specific portraits are provided for each volume in chronological order. The central historical and educational values are in the view that the books give of the world of petit-bourgeois African-American women at the turn of the century. (SLD)
78 FR 17943 - Draft Program-Specific Guidance About Fixed Gauge Licenses
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-25
... is requesting public comment on draft NUREG-1556, Volume 4, Revision 1, ``Consolidated Guidance About... sensitive information, and changes in regulatory policies and practices. This document is intended for use...-415- 4737, or by email to [email protected] . The draft NUREG-1556, Volume 4, Revision 1, is...
Hippocampal Region-Specific Contributions to Memory Performance in Normal Elderly
ERIC Educational Resources Information Center
Chen, Karren H. M.; Chuah, Lisa Y. M.; Sim, Sam K. Y.; Chee, Michael W. L.
2010-01-01
To investigate the relationship between regional hippocampal volume and memory in healthy elderly, 147 community-based volunteers, aged 55-83 years, were evaluated using magnetic resonance imaging, the Groton Maze Learning Test, Visual Reproduction and the Rey Auditory Verbal Learning Test. Hippocampal volumes were determined by interactive…
Wet Scrubber System Study. Volume II. Final Report and Bibliography.
ERIC Educational Resources Information Center
Calvert, Seymour; And Others
This report is the second volume of a two-part study on wet scrubber systems. The study was undertaken to achieve the following objectives: (1) evaluate current engineering technology, (2) evaluate existing scrubber systems, (3) investigate present usage problems, (4) determine potential new applications, and (5) develop specific research…
Is orbital volume associated with eyeball and visual cortex volume in humans?
Pearce, Eiluned; Bridge, Holly
2013-01-01
In humans orbital volume increases linearly with absolute latitude. Scaling across mammals between visual system components suggests that these larger orbits should translate into larger eyes and visual cortices in high latitude humans. Larger eyes at high latitudes may be required to maintain adequate visual acuity and enhance visual sensitivity under lower light levels. To test the assumption that orbital volume can accurately index eyeball and visual cortex volumes specifically in humans. Structural Magnetic Resonance Imaging (MRI) techniques are employed to measure eye and orbit (n = 88) and brain and visual cortex (n = 99) volumes in living humans. Facial dimensions and foramen magnum area (a proxy for body mass) were also measured. A significant positive linear relationship was found between (i) orbital and eyeball volumes, (ii) eyeball and visual cortex grey matter volumes and (iii) different visual cortical areas, independently of overall brain volume. In humans the components of the visual system scale from orbit to eye to visual cortex volume independently of overall brain size. These findings indicate that orbit volume can index eye and visual cortex volume in humans, suggesting that larger high latitude orbits do translate into larger visual cortices.
Is orbital volume associated with eyeball and visual cortex volume in humans?
Pearce, Eiluned; Bridge, Holly
2013-01-01
Background In humans orbital volume increases linearly with absolute latitude. Scaling across mammals between visual system components suggests that these larger orbits should translate into larger eyes and visual cortices in high latitude humans. Larger eyes at high latitudes may be required to maintain adequate visual acuity and enhance visual sensitivity under lower light levels. Aim To test the assumption that orbital volume can accurately index eyeball and visual cortex volumes specifically in humans. Subjects & Methods Structural Magnetic Resonance Imaging (MRI) techniques are employed to measure eye and orbit (N=88), and brain and visual cortex (N=99) volumes in living humans. Facial dimensions and foramen magnum area (a proxy for body mass) were also measured. Results A significant positive linear relationship was found between (i) orbital and eyeball volumes, (ii) eyeball and visual cortex grey matter volumes, (iii) different visual cortical areas, independently of overall brain volume. Conclusion In humans the components of the visual system scale from orbit to eye to visual cortex volume independently of overall brain size. These findings indicate that orbit volume can index eye and visual cortex volume in humans, suggesting that larger high latitude orbits do translate into larger visual cortices. PMID:23879766
Discharge formation in a XеCl laser pumped by high specific power
NASA Astrophysics Data System (ADS)
Panchenko, Yu. N.; Losev, V. F.
2013-02-01
Stable glow of the discharge of various types in the gas mixture of a XeCl laser is investigated for specific pumping power in the range 1.2-4.6 MW/cm3 and pulse duration of 40 ns. It is demonstrated that formation of partially homogeneous plasma with many intensive cathode spots on the electrode allows the maximum energy and duration of the lasing pulse to be obtained with laser efficiency of 2.4%. It is revealed that for the specific pumping powers up to 1.5 MW/cm3, a very homogeneous volume discharge with a small number of lowintensive cathode spots is formed in the discharge gap. With further increase in the specific pumping power exceeding 4.5 MW/cm3, current microinhomogeneities are formed in the volume discharge of this type leading to lasing breakdown.
NASA Technical Reports Server (NTRS)
1984-01-01
The design, development and analysis of the 7.3MW MOD-5A wind turbine generator is documented. The report is divided into four volumes: Volume 1 summarizes the entire MOD-5A program, Volume 2 discusses the conceptual and preliminary design phases, Volume 3 describes the final design of the MOD-5A, and Volume 4 contains the drawings and specifications developed for the final design. Volume 3, book 2 describes the performance and characteristics of the MOD-5A wind turbine generator in its final configuration. The subsystem for power generation, control, and instrumentation subsystems is described in detail. The manufacturing and construction plans, and the preparation of a potential site on Oahu, Hawaii, are documented. The quality assurance and safety plan, and analyses of failure modes and effects, and reliability, availability and maintainability are presented.
Janiri, Delfina; Sani, Gabriele; Rossi, Pietro De; Piras, Fabrizio; Iorio, Mariangela; Banaj, Nerisa; Giuseppin, Giulia; Spinazzola, Edoardo; Maggiora, Matteo; Ambrosi, Elisa; Simonetti, Alessio; Spalletta, Gianfranco
2017-08-01
Volumetric studies on deep gray matter structures in bipolar disorder (BP) have reported contrasting results. Childhood trauma, a relevant environmental stressor for BP, could account for the variability of the results, modulating differences in the amygdala and hippocampus in patients with BP compared with healthy controls (HC). Our study aimed to test this hypothesis. We assessed 105 outpatients, diagnosed with bipolar disorder type I (BP-I) or bipolar disorder type II (BP-II) according to DSM-IV-TR criteria, and 113 HC subjects. History of childhood trauma was obtained using the Childhood Trauma Questionnaire (CTQ). High-resolution magnetic resonance imaging was performed on all subjects and volumes of the amygdala, hippocampus, nucleus accumbens, caudate, pallidum, putamen, and thalamus were measured using FreeSurfer. Patients with BP showed a global reduction of deep gray matter volumes compared to HCs. However, childhood trauma modulated the impact of the diagnosis specifically on the amygdala and hippocampus. Childhood trauma was associated with bilateral decreased volumes in HCs and increased volumes in patients with BP. The results suggest that childhood trauma may have a different effect in health and disease on volumes of gray matter in the amygdala and hippocampus, which are brain areas specifically involved in response to stress and emotion processing. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Quebeda-Clerkin, Patricia B.; Dodge, Carter P.; Harris, Brent T.; Hillier, Simon C.; Duhaime, Ann-Christine
2012-01-01
Abstract A peripheral indicator of the presence and magnitude of brain injury has been a sought-after tool by clinicians. We measured neuron-specific enolase (NSE), myelin basic protein (MBP), and S100B, prior to and after scaled cortical impact in immature pigs, to determine if these purported markers increase after injury, correlate with the resulting lesion volume, and if these relationships vary with maturation. Scaled cortical impact resulted in increased lesion volume with increasing age. Concentrations of NSE, but not S100B or MBP, increased after injury in all age groups. The high variability of S100B concentrations prior to injury may have precluded detection of an increase due to injury. Total serum markers were estimated, accounting for the allometric growth of blood volume, and resulted in a positive correlation of both NSE and S100B with lesion volume. Even with allometric scaling of blood volume and a uniform mechanism of injury, NSE had only a fair to poor predictive value. In a clinical setting, where the types of injuries are varied, more investigation is required to yield a panel of serum markers that can reliably predict the extent of injury. Allometric scaling may improve estimation of serum marker release in pediatric populations. PMID:22867012
Ribeiro, Luís Gustavo; Busatto, Geraldo
2016-01-01
Voxel-based morphometry (VBM) is a useful approach for investigating neurostructural brain changes in dementia. We systematically reviewed VBM studies of Alzheimer's disease (AD) and mild cognitive impairment (MCI), specifically focusing on grey matter (GM) atrophy in the frontal lobe. Two searches were performed on the Pubmed database. A set of exclusion criteria was applied to ensure the selection of only VBM studies that directly investigated GM volume abnormalities in AD and/or MCI patients compared to cognitively normal controls. From a total of 46 selected articles, 35 VBM studies reported GM volume reductions in the frontal lobe. The frontal subregions, where most of the volume reductions were reported, included the inferior, superior and middle frontal gyri, as well as the anterior cingulate gyrus. We also found studies in which reduced frontal GM was detected in MCI patients who converted to AD. In a minority of studies, correlations between frontal GM volumes and behavioural changes or cognitive deficits in AD patients were investigated, with variable findings. Results of VBM studies indicate that the frontal lobe should be regarded as an important brain area when investigating GM volume deficits in association with AD. Frontal GM loss might not be a feature specific to late AD only. Future VBM studies involving large AD samples are warranted to further investigate correlations between frontal volume deficits and both cognitive impairment and neuropsychiatric symptoms.
Chuang, Michael L; Gona, Philimon; Hautvast, Gilion L T F; Salton, Carol J; Breeuwer, Marcel; O'Donnell, Christopher J; Manning, Warren J
2014-04-01
To determine sex-specific reference values for left ventricular (LV) volumes, mass, and ejection fraction (EF) in healthy adults using computer-aided analysis and to examine the effect of age on LV parameters. We examined data from 1494 members of the Framingham Heart Study Offspring cohort, obtained using short-axis stack cine SSFP CMR, identified a healthy reference group (without cardiovascular disease, hypertension, or LV wall motion abnormality) and determined sex-specific upper 95th percentile thresholds for LV volumes and mass, and lower 5th percentile thresholds for EF using computer-assisted border detection. In secondary analyses, we stratified participants by age-decade and tested for linear trend across age groups. The reference group comprised 685 adults (423F; 61 ± 9 years). Men had greater LV volumes and mass, before and after indexation to common measures of body size (all P = 0.001). Women had greater EF (73 ± 6 versus 71 ± 6%; P = 0.0002). LV volumes decreased with greater age in both sexes, even after indexation. Indexed LV mass did not vary with age. LV EF and concentricity increased with greater age in both sexes. We present CMR-derived LV reference values. There are significant age and sex differences in LV volumes, EF, and geometry, whereas mass differs between sexes but not age groups. Copyright © 2013 Wiley Periodicals, Inc.
Chuang, Michael L.; Gona, Philimon; Hautvast, Gilion L.T.F.; Salton, Carol J.; Breeuwer, Marcel; O’Donnell, Christopher J.; Manning, Warren J.
2013-01-01
Purpose To determine sex-specific reference values for left ventricular (LV) volumes, mass and ejection fraction (EF) in healthy adults using computer-aided analysis and to examine the effect of age on LV parameters. Methods and Methods We examined data from 1494 members of the Framingham Heart Study Offspring cohort, obtained using short-axis stack cine SSFP CMR, identified a healthy reference group (without cardiovascular disease, hypertension, or LV wall motion abnormality) and determined sex-specific upper 95th percentile thresholds for LV volumes and mass, and lower 5th percentile thresholds for EF using computer-assisted border detection. In secondary analyses we stratified participants by age-decade and tested for linear trend across age groups. Results The reference group comprised 685 adults (423F; 61±9 years). Men had greater LV volumes and mass, before and after indexation to common measures of body size (all p<0.001). Women had greater EF (73±6 vs. 71±6%, p=0.0002). LV volumes decreased with greater age in both sexes, even after indexation. Indexed LV mass did not vary with age. LV EF and concentricity increased with greater age in both sexes. Conclusion We present CMR-derived LV reference values. There are significant age and sex differences in LV volumes, EF and geometry, while mass differs between sexes but not age groups. PMID:24123369
Recovery of Navy distillate fuel from reclaimed product. Volume I. Technical discussion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brinkman, D.W.; Whisman, M.L.
1984-11-01
In an effort to assist the Navy to better utilize its waste hydrocarbons, NIPER, with support from the US Department of Energy, is conducting research designed to ultimately develop a practical technique for converting Reclaimed Product (RP) into specification Naval Distillate Fuel (F-76). The first phase of the project was focused on reviewing the literature and available information from equipment manufacturers. The literature survey has been carefully culled for methodology applicable to the conversion of RP into diesel fuel suitable for Navy use. Based upon the results of this study, a second phase has been developed and outlined in whichmore » experiments will be performed to determine the most practical recycling technologies. It is realized that the final selection of one particular technology may be site-specific due to vast differences in RP volume and available facilities. A final phase, if funded, would involve full-scale testing of one of the recommended techniques at a refueling depot. The Phase I investigations are published in two volumes. Volume 1, Technical Discussion, includes the narrative and Appendices I and II. Appendix III, a detailed Literature Review, includes both a narrative portion and an annotated bibliography containing about 800 referenvces and abstracts. This appendix, because of its volume, has been published separately as Volume 2. 18 figures, 4 tables.« less
Extraction of membrane structure in eyeball from MR volumes
NASA Astrophysics Data System (ADS)
Oda, Masahiro; Kin, Taichi; Mori, Kensaku
2017-03-01
This paper presents an accurate extraction method of spherical shaped membrane structures in the eyeball from MR volumes. In ophthalmic surgery, operation field is limited to a small region. Patient specific surgical simulation is useful to reduce complications. Understanding of tissue structure in the eyeball of a patient is required to achieve patient specific surgical simulations. Previous extraction methods of tissue structure in the eyeball use optical coherence tomography (OCT) images. Although OCT images have high resolution, imaging regions are limited to very small. Global structure extraction of the eyeball is difficult from OCT images. We propose an extraction method of spherical shaped membrane structures including the sclerotic coat, choroid, and retina. This method is applied to a T2 weighted MR volume of the head region. MR volume can capture tissue structure of whole eyeball. Because we use MR volumes, out method extracts whole membrane structures in the eyeball. We roughly extract membrane structures by applying a sheet structure enhancement filter. The rough extraction result includes parts of the membrane structures. Then, we apply the Hough transform to extract a sphere structure from the voxels set of the rough extraction result. The Hough transform finds a sphere structure from the rough extraction result. An experimental result using a T2 weighted MR volume of the head region showed that the proposed method can extract spherical shaped membrane structures accurately.
Brain tissue volumes in relation to cognitive function and risk of dementia.
Ikram, M Arfan; Vrooman, Henri A; Vernooij, Meike W; den Heijer, Tom; Hofman, Albert; Niessen, Wiro J; van der Lugt, Aad; Koudstaal, Peter J; Breteler, Monique M B
2010-03-01
We investigated in a population-based cohort study the association of global and lobar brain tissue volumes with specific cognitive domains and risk of dementia. Participants (n=490; 60-90 years) were non-demented at baseline (1995-1996). From baseline brain MRI-scans we obtained global and lobar volumes of CSF, GM, normal WM, white matter lesions and hippocampus. We performed neuropsychological testing at baseline to assess information processing speed, executive function, memory function and global cognitive function. Participants were followed for incident dementia until January 1, 2005. Larger volumes of CSF and WML were associated with worse performance on all neuropsychological tests, and an increased risk of dementia. Smaller WM volume was related to poorer information processing speed and executive function. In contrast, smaller GM volume was associated with worse memory function and increased risk of dementia. When investigating lobar GM volumes, we found that hippocampal volume and temporal GM volume were most strongly associated with risk of dementia, even in persons without objective and subjective cognitive deficits at baseline, followed by frontal and parietal GM volumes. Copyright 2008 Elsevier Inc. All rights reserved.
Survival in pediatric lung transplantation: The effect of center volume and expertise.
Khan, Muhammad S; Zhang, Wei; Taylor, Rachel A; Dean McKenzie, E; Mallory, George B; Schecter, Marc G; Morales, David L S; Heinle, Jeffrey S; Adachi, Iki
2015-08-01
Institutional operative volume has been shown to impact outcomes of various procedures including lung transplantation (LTx). We sought to determine whether this holds true with pediatric LTx by comparing outcomes of adult centers (with larger overall volume) to those of pediatric centers (with smaller volume but more pediatric-specific experience). A retrospective analysis of the Organ Procurement and Transplant Network data was performed. Centers were categorized as either adult (LTx volume predominantly in adult patients), high-volume pediatric (HVP, ≥4 LTxs/year), or low-volume pediatric (LVP, <4 LTxs/year). Outcomes were compared in "younger children" (<12 years) and "older children and adolescents" (12 to 17 years). In total, 1,046 pediatric LTxs were performed between 1987 and 2012 at 62 centers (adult 51 [82%], HVP 3 [5%], LVP 8 [13%]). Although adult centers had larger overall LTx volume, their pediatric experiences were severely limited (median 1/year). In younger children, HVP centers were significantly better than LVP centers for patient survival (half-life: 7.3 vs 2.9 years, p = 0.002). Similarly, in older children and adolescents, HVP centers were significantly better than adult centers for patient survival (half-life: 4.6 vs 2.5 years, p = 0.001). Of note, even LVP centers tended to have longer patient survival than adult centers (p = 0.064). Multivariable analysis identified adult centers as an independent risk factor for graft failure (hazard ratio: 1.5, p < 0.001) as with LVP (hazard ratio: 1.3, p = 0.0078). Despite larger overall clinical volume, outcomes among pediatric LTx recipients in adult centers are not superior to those of pediatric centers. Not only center volume but pediatric-specific experience has an impact on outcomes in pediatric LTx. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Dunham, P B; Ellory, J C
1981-01-01
The major pathway of passive K influx (ouabain-insensitive) was characterized in low-K type (LK) red cells of sheep. 1. Passive K transport in these cells was highly sensitive to variations in cell volume; it increased threefold or more in cells swollen osmotically by 10%, and decreased up to twofold in cells shrunken 5-10%. Active K influx was insensitive to changes in cell volume. Three different methods for varying cell volume osmotically all gave similar results. 2. The volume-sensitive pathway was specific for K in that Na influx did not vary with changes in cell volume. 3. The volume-sensitive K influx was a saturable function of external K concentration. It was slightly inhibited by Na, whereas K influx in shrunken cells was unaffected by Na. 4. Passive K influx was dependent on the major anion in the medium in that replacement of Cl with any of six other anions resulted in a reduction of K influx by 50-80% (replacement of Cl by Br caused an increase in K influx). The activation of K influx by Cl followed sigmoid kinetics. 5. Passive K influx is inhibited by anti-L antibody. The antibody affected only that portion of influx which was Cl-dependent and volume-sensitve. Of the subfractions of the antibody, it is anti-L1 which inhibits passive K transport. 6. Pretreatment of cells with iodoacetamide reduced the sensitivity of K influx to cell volume in that the influx was reduced in swollen IAA-treated cells and increased in shrunken IAA-cells. 7. Intracellular Ca has no role in altering passive K transport in LK sheep cells. Therefore, the major pathway of passive K transport in LK sheep red cells is sensitive to changes in cell volume, specific for K, dependent on Cl, and inhibited by anti-L1 antibody, The minor pathway, observed in shrunken cells, has none of these properties. PMID:6798197
Rosso, Isabelle M; Makris, Nikos; Britton, Jennifer C; Price, Lauren M; Gold, Andrea L; Zai, David; Bruyere, John; Deckersbach, Thilo; Killgore, William D S; Rauch, Scott L
2010-12-01
Anxiety sensitivity (AS) is a dispositional trait involving fear of anxiety-related symptoms. Functional imaging research suggests that the activity of the anterior insular cortex, particularly the right insula, may both mediate AS and play a role in the pathophysiology of phobias. However, no imaging studies have examined whether AS relates to insula morphology. We examined whether AS was significantly correlated with right anterior insula volume and thickness among adults with specific animal phobia (SAP) and healthy comparison (HC) subjects. Nineteen adults with SAP and 20 demographically group-matched HC subjects underwent magnetic resonance imaging at 3 Tesla. Subjects also completed the Anxiety Sensitivity Index (ASI). Regression and correlation analyses examined ASI scores in relation to anterior and posterior insular cortex volume and thickness within and across subject groups. SAP subjects had significantly higher ASI scores than HC, but did not differ in terms of insula volumes or thickness. ASI scores predicted right anterior insula thickness in SAP but not HC subjects, and right anterior insula volume in the sample as a whole. Correlations of ASI scores with the anterior and posterior insula volume and thickness were not significant in either group. These findings suggest that the right anterior insular cortex size is a neural substrate of AS within specific phobia, rather than an independent diagnostic marker of the disorder. Future investigations should examine whether heightened AS represents a shared intermediate phenotype across anxiety disorders, manifesting functionally as increased insular reactivity and clinically as a fear of anxiety symptoms. © 2010 Wiley-Liss, Inc.
Rosso, Isabelle M.; Makris, Nikos; Britton, Jennifer C.; Price, Lauren M.; Gold, Andrea L.; Zai, David; Bruyere, John; Deckersbach, Thilo; Killgore, William D. S.; Rauch, Scott L.
2010-01-01
Background Anxiety sensitivity (AS) is a dispositional trait involving fear of anxiety-related symptoms. Functional imaging research suggests that activity of the anterior insular cortex, particularly the right insula, may both mediate AS and play a role in the pathophysiology of phobias. However, no imaging studies have examined whether AS relates to insula morphology. We examined whether AS was significantly correlated with right anterior insula volume and thickness among adults with specific animal phobia (SAP) and healthy comparison (HC) subjects. Methods Nineteen adults with SAP and 20 demographically group-matched HC subjects underwent magnetic resonance imaging (MRI) at 3 Tesla. Subjects also completed the Anxiety Sensitivity Index (ASI). Regression and correlation analyses examined ASI scores in relation to anterior and posterior insular cortex volume and thickness within and across subject groups. Results SAP subjects had significantly higher ASI scores than HC, but did not differ in terms of insula volumes or thickness. ASI scores predicted right anterior insula thickness in SAP but not HC subjects, and right anterior insula volume in the sample as a whole. Correlations of ASI scores with left anterior and posterior insula volume and thickness were not significant in either group. Conclusions These findings suggest that right anterior insular cortex size is a neural substrate of AS within specific phobia, rather than an independent diagnostic marker of the disorder. Future investigations should examine whether heightened AS represents a shared intermediate phenotype across anxiety disorders, manifesting functionally as increased insular reactivity and clinically as a fear of anxiety symptoms. PMID:21132846
Eu, Byung Chan
2008-09-07
In the traditional theories of irreversible thermodynamics and fluid mechanics, the specific volume and molar volume have been interchangeably used for pure fluids, but in this work we show that they should be distinguished from each other and given distinctive statistical mechanical representations. In this paper, we present a general formula for the statistical mechanical representation of molecular domain (volume or space) by using the Voronoi volume and its mean value that may be regarded as molar domain (volume) and also the statistical mechanical representation of volume flux. By using their statistical mechanical formulas, the evolution equations of volume transport are derived from the generalized Boltzmann equation of fluids. Approximate solutions of the evolution equations of volume transport provides kinetic theory formulas for the molecular domain, the constitutive equations for molar domain (volume) and volume flux, and the dissipation of energy associated with volume transport. Together with the constitutive equation for the mean velocity of the fluid obtained in a previous paper, the evolution equations for volume transport not only shed a fresh light on, and insight into, irreversible phenomena in fluids but also can be applied to study fluid flow problems in a manner hitherto unavailable in fluid dynamics and irreversible thermodynamics. Their roles in the generalized hydrodynamics will be considered in the sequel.
Suero, Eduardo M; Lueke, Ulrich; Stuebig, Timo; Hawi, Nael; Krettek, Christian; Liodakis, Emmanouil
2018-04-25
Procedure volume is an important determinant of total knee arthroplasty (TKA) outcomes. We aimed to determine whether computer navigation or patient-specific instrumentation (PSI) would improve postoperative alignment in a low-volume setting. PSI for TKA achieves better limb and implant alignment compared to conventional TKA and to computer navigated TKA. This is a retrospective cohort study of 385 primary TKAs (Women=59%. Mean age=67years. Mean BMI=30.1kg/m 2 ), which were performed using conventional instrumentation (n=117; 30%), computer navigation (n=209; 54%), or patient-specific instrumentation (n=59; 15%) in a low-volume center (<50 TKAs/year). The risk of postoperative leg and implant mechanical alignment outliers in the coronal plane (>3° from neutral), average alignment and operation time were assessed. The risk of postoperative mechanical alignment outliers (>3°) was reduced by 89% in the navigated group (4% outliers) compared to the conventional group (35%) (RR=0.11; p<0.0001). No significant improvement was observed in the PSI group (27%) (RR=0.91; p=0.772). The risk of postoperative femoral component coronal alignment outliers was reduced by 63% in the navigated group (11%) compared to the conventional group (31%) (RR=0.37; p=0.018). No significant reduction in outliers was observed in the PSI group (32%) (RR=1.08; p=0.816). There was a reduction in the risk of tibial component coronal malalignment of 66% in the navigated group (5%) compared to the conventional group (13%) (RR=0.33; p=0.070). There was a two-fold increase in the risk of tibial component alignment outliers in the PSI group (29%) (RR=1.94; p=0.110). Computer navigation improved postoperative alignment in TKA. No evidence of improved alignment was seen with patient-specific instrumentation. The routine use of patient-specific instrumentation in low-volume centers is not supported by the currently available data. Retrospective cohort study. Level IV. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Joly, Florian; Soulez, Gilles; Garcia, Damien; Lessard, Simon; Kauffmann, Claude
2018-01-01
Abdominal aortic aneurysms (AAA) are localized, commonly-occurring dilations of the aorta. When equilibrium between blood pressure (loading) and wall mechanical resistance is lost, rupture ensues, and patient death follows, if not treated immediately. Experimental and numerical analyses of flow patterns in arteries show direct correlations between wall shear stress and wall mechano-adaptation with the development of zones prone to thrombus formation. For further insights into AAA flow topology/growth interaction, a workout of patient-specific computational flow dynamics (CFD) is proposed to compute finite-time Lyapunov exponents and extract Lagrangian-coherent structures (LCS). This computational model was first compared with 4-D phase-contrast magnetic resonance imaging (MRI) in 5 patients. To better understand the impact of flow topology and transport on AAA growth, hyperbolic, repelling LCS were computed in 1 patient during 8-year follow-up, including 9 volumetric morphologic AAA measures by computed tomography-angiography (CTA). LCS defined barriers to Lagrangian jet cores entering AAA. Domains enclosed between LCS and the aortic wall were considered to be stagnation zones. Their evolution was studied during AAA growth. Good correlation - 2-D cross-correlation coefficients of 0.65, 0.86 and 0.082 (min, max, SD) - was obtained between numerical simulations and 4-D MRI acquisitions in 6 specific cross-sections from 4 patients. In follow-up study, LCS divided AAA lumens into 3 dynamically-isolated zones: 2 stagnation volumes lying in dilated portions of the AAA, and circulating volume connecting the inlet to the outlet. The volume of each zone was tracked over time. Although circulating volume remained unchanged during 8-year follow-up, the AAA lumen and main stagnation zones grew significantly (8 cm 3 /year and 6 cm 3 /year, respectively). This study reveals that transient transport topology can be quantified in patient-specific AAA during disease progression by CTA, in parallel with lumen morphology. It is anticipated that analysis of the main AAA stagnation zones by patient-specific CFD on a yearly basis could help to predict AAA growth and rupture. Copyright © 2017 Elsevier Ltd. All rights reserved.
Dielectric properties, optimum formulation and microwave baking conditions of chickpea cakes.
Alifakı, Yaşar Özlem; Şakıyan, Özge
2017-03-01
The aim of this study was to correlate dielectric properties with quality parameters, and to optimize cake formulation and baking conditions by response surface methodology. Weight loss, color, specific volume, hardness and porosity were evaluated. The samples with different DATEM (0.4, 0.8 and 1.2%) and chickpea flour concentrations (30, 40 and 50%) were baked in microwave oven at different power (300, 350, 400 W) and baking times (2.50, 3.0, 3.50 min). It was found that microwave power showed significant effect on color, while baking time showed effect on weight loss, porosity, hardness, specific volume and dielectric properties. Emulsifier level affected porosity, specific volume and dielectric constant. Chickpea flour level affected porosity, color, hardness and dielectric properties of cakes. The optimum microwave power, baking time, DATEM level and chickpea flour level were found as 400 W, 2.84 min, 1.2% and 30%, respectively. The comparison between conventionally baked and the microwave baked cakes at optimum points showed that color difference, weight loss, specific volume and porosity values of microwave baked cakes were less than those of conventionally baked cakes, on the other hand, hardness values were higher. Moreover, a negative correlation between dielectric constant and porosity, and weight loss values were detected for microwave baked samples. A negative correlation between dielectric loss factor and porosity was observed. These correlations indicated that quality characteristics of a microwave baked cake sample can be assessed from dielectric properties. These correlations provides understanding on the behavior of food material during microwave processing.
The future of automation for high-volume wafer fabrication and ASIC manufacturing
NASA Astrophysics Data System (ADS)
Hughes, Randall A.; Shott, John D.
1986-12-01
A framework is given to analyze the future trends in semiconductor manufacturing automation systems, focusing specifically on the needs of ASIC (application-specific integrated circuit) or custom integrated circuit manufacturing. Advances in technologies such as gate arrays and standard cells now make it significantly easier to obtain system cost and performance advantages by integrating nonstandard functions on silicon. ASICs are attractive to U.S. manufacturers because they place a premium on sophisticated design tools, familiarity with customer needs and applications, and fast turn-around fabrication. These are areas where U.S. manufacturers believe they have an advantage and, consequently, will not suffer from the severe price/manufacturing competition encountered in conventional high-volume semiconductor products. Previously, automation was often considered viable only for high-volume manufacturing, but automation becomes a necessity in the new ASIC environment.
Kaag, A M; Schulte, M H J; Jansen, J M; van Wingen, G; Homberg, J; van den Brink, W; Wiers, R W; Schmaal, L; Goudriaan, A E; Reneman, L
2018-06-01
Neuroimaging studies have demonstrated gray matter (GM) volume abnormalities in substance users. While the majority of substance users are polysubstance users, very little is known about the relation between GM volume abnormalities and polysubstance use. In this study we assessed the relation between GM volume, and the use of alcohol, tobacco, cocaine and cannabis as well as the total number of substances used, in a sample of 169 males: 15 non-substance users, 89 moderate drinkers, 27 moderate drinkers who also smoke tobacco, 13 moderate drinkers who also smoke tobacco and use cocaine, 10 heavy drinkers who smoke tobacco and use cocaine and 15 heavy drinkers who smoke tobacco, cannabis and use cocaine. Regression analyses showed that there was a negative relation between the number of substances used and volume of the dorsal medial prefrontal cortex (mPFC) and the ventral mPFC. Without controlling for the use of other substances, the volume of the dorsal mPFC was negatively associated with the use of alcohol, tobacco, and cocaine. After controlling for the use of other substances, a negative relation was found between tobacco and cocaine and volume of the thalami and ventrolateral PFC, respectively. These findings indicate that mPFC alterations may not be substance-specific, but rather related to the number of substances used, whereas, thalamic and ventrolateral PFC pathology is specifically associated with tobacco and cocaine use, respectively. These findings are important, as the differential alterations in GM volume may underlie different cognitive deficits associated with substance use disorders. Copyright © 2018 Elsevier B.V. All rights reserved.
Specific yield: compilation of specific yields for various materials
Johnson, A.I.
1967-01-01
Specific yield is defined as the ratio of (1) the volume of water that a saturated rock or soil will yield by gravity to (2) the total volume of the rock or soft. Specific yield is usually expressed as a percentage. The value is not definitive, because the quantity of water that will drain by gravity depends on variables such as duration of drainage, temperature, mineral composition of the water, and various physical characteristics of the rock or soil under consideration. Values of specific yields nevertheless offer a convenient means by which hydrologists can estimate the water-yielding capacities of earth materials and, as such, are very useful in hydrologic studies. The present report consists mostly of direct or modified quotations from many selected reports that present and evaluate methods for determining specific yield, limitations of those methods, and results of the determinations made on a wide variety of rock and soil materials. Although no particular values are recommended in this report, a table summarizes values of specific yield, and their averages, determined for 10 rock textures. The following is an abstract of the table. [Table
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jung, Y; Johnston, M; Whitlow, C
Purpose: To demonstrate the feasibility of a novel method for size specific arterial cerebral blood volume (aCBV) mapping using pseudo-continuous arterial spin labeling (PCASL), with multiple TI. Methods: Multiple PCASL images were obtained from a subject with TI of [300, 400, 500, 600, 700, 800, 900, 1000, 1500, 2000, 2500, 3000, 3500, 4000] ms. Each TI pair was averaged six times. Two scans were performed: one without a flow crusher gradient and the other with a crusher gradient (10cm/s in three directions) to remove signals from large arteries. Scan times were 5min. without a crusher gradient and 5.5 min withmore » a crusher gradient. Non-linear fitting algorithm finds the minimum mean squared solution of per-voxel based aCBV, cerebral blood flow, and arterial transit time, and fits the data into a hemodynamic model that represents superposition of blood volume and flow components within a single voxel. Results: aCBV maps with a crusher gradient represent signals from medium and small sized arteries, while those without a crusher gradient represent signals from all sized arteries, indicating that flow crusher gradients can be effectively employed to achieve size-specific aCBV mapping. Regardless of flow crusher, the CBF and ATT maps are very similar in appearance. Conclusion: Quantitative size selective blood volume mapping controlled by a flow crusher is feasible without additional information because the ASL quantification process doesn’t require an arterial input function measured from a large artery. The size specific blood volume mapping is not interfered by sSignals from large arteries do not interfere with size specific aCBV mapping in the applications of interest in for applications in which only medium or small arteries are of interest.« less
Flight Weight Design Nickel-Hydrogen Cells Using Lightweight Nickel Fiber Electrodes
NASA Technical Reports Server (NTRS)
Britton, Doris L.; Willis, Bob; Pickett, David F.
2003-01-01
The goal of this program is to develop a lightweight nickel electrode for advanced aerospace nickel-hydrogen cells and batteries with improved specific energy and specific volume. The lightweight nickel electrode will improve the specific energy of a nickel-hydrogen cell by >50%. These near-term advanced batteries will reduce power system mass and volume, while decreasing the cost, thus increasing mission capabilities and enabling small spacecraft missions. This development also offers a cost savings over the traditional sinter development methods for fabrication. The technology has been transferred to Eagle-Picher, a major aerospace battery manufacturer, who has scaled up the process developed at NASA GRC and fabricated electrodes for incorporation into flight-weight nickel-hydrogen cells.
Development of a patient-specific model for calculation of pulmonary function
NASA Astrophysics Data System (ADS)
Zhong, Hualiang; Ding, Mingyue; Movsas, Benjamin; Chetty, Indrin J.
2011-06-01
The purpose of this paper is to develop a patient-specific finite element model (FEM) to calculate the pulmonary function of lung cancer patients for evaluation of radiation treatment. The lung model was created with an in-house developed FEM software with region-specific parameters derived from a four-dimensional CT (4DCT) image. The model was used first to calculate changes in air volume and elastic stress in the lung, and then to calculate regional compliance defined as the change in air volume corrected by its associated stress. The results have shown that the resultant compliance images can reveal the regional elastic property of lung tissue, and could be useful for radiation treatment planning and assessment.
Shen, Jiacheng; Zhu, Jun
2016-01-01
Poultry litter (PL) can be good feedstock for biogas production using anaerobic digestion. In this study, methane production from batch co-digestion of PL and wheat straw (WS) was investigated for two factors, i.e., total solid (2%, 5%, and 10%) and volatile solid (0, 25, and 50% of WS), constituting a 3 × 3 experimental design. The results showed that the maximum specific methane volume [197 mL (g VS)(‑1)] was achieved at 50% VS from WS at 5% TS level. It was estimated that the inhibitory threshold of free ammonia was about 289 mg L(--1), beyond which reduction of methanogenic activity by at least 54% was observed. The specific methane volume and COD removal can be expressed using two response surface models (R(2) = 0.9570 and 0.9704, respectively). Analysis of variance of the experimental results indicated that the C/N ratio was the most significant factor influencing the specific methane volume and COD removal in the co-digestion of these two materials.
Enhanced surveillance program FY97 accomplishments. Progress report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mauzy, A.; Laake, B.
1997-10-01
This annual report is one volume of the Enhanced Surveillance Program (ESP) FY97 Accomplishments. The complete accomplishments report consists of 11 volumes. Volume 1 includes an ESP overview and a summary of selected unclassified FY97 program highlights. Volume 1 specifically targets a general audience, reflecting about half of the tasks conducted in FY97 and emphasizing key program accomplishments and contributions. The remaining volumes of the accomplishments report are classified, organized by program focus area, and present in technical detail the progress achieved in each of the 104 FY97 program tasks. Focus areas are as follows: pits; high explosives; organics; dynamics;more » diagnostics; systems; secondaries; nonnuclear materials; nonnuclear components; and Surveillance Test Program upgrades.« less
Compiler writing system detail design specification. Volume 1: Language specification
NASA Technical Reports Server (NTRS)
Arthur, W. J.
1974-01-01
Construction within the Meta language for both language and target machine specification is reported. The elements of the function language as a meaning and syntax are presented, and the structure of the target language is described which represents the target dependent object text representation of applications programs.
An update on airborne contact dermatitis.
Huygens, S; Goossens, A
2001-01-01
This review is an update of 2 previously published articles on airborne contact dermatoses. Because reports in the literature often omit the term 'airborne', 18 volumes of Contact Dermatitis (April 1991-June 2000), 8 volumes of the American Journal of Contact Dermatitis (1992 1999) and 4 volumes of La Lettre du Gerda (1996-1999) were screened, and the cases cited were classified as to history, lesion locations, sensitization sources, and other factors. Reports on airborne dermatitis are increasingly being published, sometimes in relation to specific occupational areas.
Anomalous volume change of gramicidin A in ethanol solutions
NASA Technical Reports Server (NTRS)
Derechin, M.; Hayashi, D. M.; Jordan, B. E.
1975-01-01
Results of studies aimed at clarifying the failure of gramicidin A (GA) to sediment in early experiments are analyzed. In the present work, no sedimentation was observed in pure pentanol or ethanol, while normal sedimentation was observed in ethanol-water mixtures. It is concluded that GA exists in two conformations that differ in volume. Since the apparent specific volume in absolute ethanol sinks to its lowest values on increasing concentration, the GA molecule probably unfolds completely in conditions favorable for dimerization.
1989-09-30
information for use by readers to interpret the tabulation volumes accompanying the final project report: 1989 Survey of U.S. Army Reserve (USAR) Troop...34stayers" who were used as the sample to generate the first longitudinal Tabulation Volume. Comparing questionnaire response frequencies between the...as described below). Detailed below are the specific crossing variables used for the cross-sectional and longitudinal Tabulation Volumes. Cross
The Stochastic Evolution of a Protocell: The Gillespie Algorithm in a Dynamically Varying Volume
Carletti, T.; Filisetti, A.
2012-01-01
We propose an improvement of the Gillespie algorithm allowing us to study the time evolution of an ensemble of chemical reactions occurring in a varying volume, whose growth is directly related to the amount of some specific molecules, belonging to the reactions set. This allows us to study the stochastic evolution of a protocell, whose volume increases because of the production of container molecules. Several protocell models are considered and compared with the deterministic models. PMID:22536297
Denoising and 4D visualization of OCT images
Gargesha, Madhusudhana; Jenkins, Michael W.; Rollins, Andrew M.; Wilson, David L.
2009-01-01
We are using Optical Coherence Tomography (OCT) to image structure and function of the developing embryonic heart in avian models. Fast OCT imaging produces very large 3D (2D + time) and 4D (3D volumes + time) data sets, which greatly challenge ones ability to visualize results. Noise in OCT images poses additional challenges. We created an algorithm with a quick, data set specific optimization for reduction of both shot and speckle noise and applied it to 3D visualization and image segmentation in OCT. When compared to baseline algorithms (median, Wiener, orthogonal wavelet, basic non-orthogonal wavelet), a panel of experts judged the new algorithm to give much improved volume renderings concerning both noise and 3D visualization. Specifically, the algorithm provided a better visualization of the myocardial and endocardial surfaces, and the interaction of the embryonic heart tube with surrounding tissue. Quantitative evaluation using an image quality figure of merit also indicated superiority of the new algorithm. Noise reduction aided semi-automatic 2D image segmentation, as quantitatively evaluated using a contour distance measure with respect to an expert segmented contour. In conclusion, the noise reduction algorithm should be quite useful for visualization and quantitative measurements (e.g., heart volume, stroke volume, contraction velocity, etc.) in OCT embryo images. With its semi-automatic, data set specific optimization, we believe that the algorithm can be applied to OCT images from other applications. PMID:18679509
Opportunities in Total Knee Arthroplasty: Worldwide Surgeons' Perspective.
Dunbar, Michael; Newman, Jared M; Khlopas, Anton; Chughtai, Morad; Martinez, Nick; Bhowmik-Stoker, Manoshi; Mont, Michael A
2017-07-25
This study surveyed a group of US and international orthopaedic surgeons to prioritize areas of improvement in primary total knee arthroplasty (TKA). Specifically, we assessed surgeon responses regarding the top five areas of TKA needing improvement; which were stratified by: a) US surgeons, b) international surgeons, c) US surgeons' implant-brand-loyalty, and d) surgeons' years of experience and case volume. Four hundred and eighteen surgeons who were board-certified, in practice for at least two years, spent 60% of their time in clinical practice, and performed a minimum of 25 lower extremity joint arthroplasties per year were surveyed. They chose the top five areas (among 17) needing improvement for TKA. Results were stratified by surgeons' location (US and international), implant-brand-loyalty, years of experience, and case volume. Functional outcomes was the top identified area for improvement (US 63% and international 71%), followed by brand loyalty (Company I 68%, other brand 59%, and multi-brand/no loyalty 66%), years of experience (early-career 64%, mid-career 63%, and late-career 75%) and case volume (low-volume 69%, mid-volume 60%, and high-volume 71%). Following this was costs for US surgeons (47%) and implant survivorship for international surgeons (57%). While costs were the next highest area for specific Company-loyal surgeons (57%), implant survivorship was the next highest area for the other two cohorts. Implant survivorship was the second most important area of improvement regardless of years of experience and for low- and mid-volume surgeons. Surgeons identified functional outcomes as the most important area needing improvement. Cost of implants was more important for American as compared to international surgeons.
Prostate specific antigen and acinar density: a new dimension, the "Prostatocrit".
Robinson, Simon; Laniado, Marc; Montgomery, Bruce
2017-01-01
Prostate-specific antigen densities have limited success in diagnosing prostate cancer. We emphasise the importance of the peripheral zone when considered with its cellular constituents, the "prostatocrit". Using zonal volumes and asymmetry of glandular acini, we generate a peripheral zone acinar volume and density. With the ratio to the whole gland, we can better predict high grade and all grade cancer. We can model the gland into its acinar and stromal elements. This new "prostatocrit" model could offer more accurate nomograms for biopsy. 674 patients underwent TRUS and biopsy. Whole gland and zonal volumes were recorded. We compared ratio and acinar volumes when added to a "clinic" model using traditional PSA density. Univariate logistic regression was used to find significant predictors for all and high grade cancer. Backwards multiple logistic regression was used to generate ROC curves comparing the new model to conventional density and PSA alone. Prediction of all grades of prostate cancer: significant variables revealed four significant "prostatocrit" parameters: log peripheral zone acinar density; peripheral zone acinar volume/whole gland acinar volume; peripheral zone acinar density/whole gland volume; peripheral zone acinar density. Acinar model (AUC 0.774), clinic model (AUC 0.745) (P=0.0105). Prediction of high grade prostate cancer: peripheral zone acinar density ("prostatocrit") was the only significant density predictor. Acinar model (AUC 0.811), clinic model (AUC 0.769) (P=0.0005). There is renewed use for ratio and "prostatocrit" density of the peripheral zone in predicting cancer. This outperforms all traditional density measurements. Copyright® by the International Brazilian Journal of Urology.
USDA-ARS?s Scientific Manuscript database
Naturally-occurring inhibitory compounds are a major concern during qPCR and RT-qPCR analysis of environmental samples, particularly large volume water samples. Here, a standardized method for measuring and mitigating sample inhibition in environmental water concentrates is described. Specifically, ...
Native Aging Visions: A Resource for Native Elders. Volume 1, 1994-97.
ERIC Educational Resources Information Center
Native Aging Visions, 1997
1997-01-01
This volume of newsletters reports on the activities and research projects of the National Resource Center on Native American Aging located at the University of North Dakota, Grand Forks. The Center studies health issues and access problems facing American Indian, Alaska Native, and Native Hawaiian elders. Specifically, the resource center was…
Technology and Learning: Changing Minds in a Changing World. Schooling and Technology, Volume 4.
ERIC Educational Resources Information Center
Willis, Bernice H.; And Others
This document, the publishers' fourth volume on schooling and technology, explores in detail the mismatch between the historically developed purposes, roles, and practices of the schools and the nature of the new technology. Specifically, it juxtaposes characteristics of today's children and the currently available educational technologies…
A DDC Bibliography on Computers in Information Sciences. Volume I. Information Sciences Series.
ERIC Educational Resources Information Center
Defense Documentation Center, Alexandria, VA.
The unclassified and unlimited bibliography compiles references dealing specifically with the role of computers in information sciences. The volume contains 249 annotated references grouped under two major headings: Time Shared, On-Line, and Real Time Systems, and Computer Components. The references are arranged in accesion number (AD-number)…
A feasibility study of limb volume measuring systems
NASA Technical Reports Server (NTRS)
Lafferty, J. F.; Carter, W. M.
1974-01-01
Evaluation of the various techniques by which limb volume can be measured indicates that the odometric (electromechanical) method and the reflective scanner (optical) have a high probability of meeting the specifications of the LBNP experiments. Both of these methods provide segmental measurements from which the cross sectional area of the limb can be determined.
Looking for Marx: A Review of "Marx and Education" by Jean Anyon
ERIC Educational Resources Information Center
Banfield, Grant
2011-01-01
"Marx and Education" is the second and latest volume in the new "Routledge Key Ideas in Education Series". The series is intended to offer readers concise introductions to specific sub-field developments in the field of educational scholarship. For their "Marx and Education" volume, Greg Dimitriadis and Bob Lingard…
40 CFR 1037.705 - Generating and calculating emission credits.
Code of Federal Regulations, 2013 CFR
2013-07-01
... equations: (1) For vocational vehicles: Emission credits (Mg) = (Std-FEL) × (Payload Tons) × (Volume) × (UL) × (10−6) Where: Std = the emission standard associated with the specific tractor regulatory subcategory... credits (Mg) = (Std-FEL) × (Payload tons) × (Volume) × (UL) × (10−6) Where: Std = the emission standard...
40 CFR 1037.705 - Generating and calculating emission credits.
Code of Federal Regulations, 2012 CFR
2012-07-01
... equations: (1) For vocational vehicles: Emission credits (Mg) = (Std-FEL) × (Payload Tons) × (Volume) × (UL) × (10−6) Where: Std = the emission standard associated with the specific tractor regulatory subcategory... credits (Mg) = (Std-FEL) × (Payload tons) × (Volume) × (UL) × (10−6) Where: Std = the emission standard...
40 CFR 1037.705 - Generating and calculating emission credits.
Code of Federal Regulations, 2014 CFR
2014-07-01
... equations: (1) For vocational vehicles: Emission credits (Mg) = (Std-FEL) × (Payload Tons) × (Volume) × (UL) × (10−6) Where: Std = the emission standard associated with the specific tractor regulatory subcategory... credits (Mg) = (Std-FEL) × (Payload tons) × (Volume) × (UL) × (10−6) Where: Std = the emission standard...
Classroom Communication and Instructional Processes: Advances through Meta-Analysis
ERIC Educational Resources Information Center
Gayle, Barbara Mae, Ed.; Preiss, Raymond W., Ed.; Burrell, Nancy, Ed.; Allen, Mike, Ed.
2006-01-01
This volume offers a systematic review of the literature on communication education and instruction. Making meta-analysis findings accessible and relevant, the editors of this volume approach the topic from the perspective that meta-analysis serves as a useful tool for summarizing experiments and for determining how and why specific teaching and…
Choice: A Thematic Sequence of English Units.
ERIC Educational Resources Information Center
Institute for Services to Education, Inc., Washington, DC.
One of a series of volumes containing units on specific themes designed for use in college freshman English courses, this particular volume considers the issue of choice through literature (short stories, novels, and poems). A section describing chamber theatre technique, which is an integral part of many of the units in this sequence, is…
Huizinga, Richard J.
2014-01-01
The rainfall-runoff pairs from the storm-specific GUH analysis were further analyzed against various basin and rainfall characteristics to develop equations to estimate the peak streamflow and flood volume based on a quantity of rainfall on the basin.
Contemporary Navajo Affairs: Navajo History Volume III, Part B.
ERIC Educational Resources Information Center
Eck, Norman K.
Written specifically for Navajo junior high through college students, but also serving those interested in modern reservation developments and processs, the third volume of a curricular series on Navajo history provides a synthesis of data and pictorial records on current events in the areas of Navajo government, economic development, and health.…
Federal Student Aid Handbook, 2006-2007. Volume 6: Campus-Based Programs
ERIC Educational Resources Information Center
US Department of Education, 2006
2006-01-01
The Federal Perkins Loan, Federal Supplemental Educational Opportunity Grant (FSEOG), and Federal Work-Study (FWS) programs are called "campus-based" programs because each school is responsible for administering them on its own campus. This volume gives guidance on issues specific to the administration of the campus-based programs.…
Negotiating Salaries, Volume II.
ERIC Educational Resources Information Center
Educational Service Bureau, Inc., Washington, DC.
This volume discusses specific strategy and tactics that can be employed in the effort to reach an agreement on salaries at the bargaining table. Although strategies and situations may vary from case to case, this report focuses on those principles and approaches that are essential to any good bargaining procedure. The discussion covers public vs.…
Population Education Interchange. Volume 17, Numbers 1-4, 1988.
ERIC Educational Resources Information Center
Crews, Kimberly A.
1988-01-01
The four issues of this volume are each concerned with a specific topic in population studies. Issue number 1 , "Demographic Illiteracy," indicates that U.S. students are not aware of world population growth patterns. The information is taken from the Second International Science Study, 1983. An annotated list of 16 population studies resources is…
40 CFR 799.2155 - Commercial hexane.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) “Commercial hexane,” for purposes of this section, is a product obtained from crude oil, natural gas liquids... least 40 liquid volume percent n-hexane (CAS No. 110-54-3) and at least 5 liquid volume percent... section, is a product which conforms to the specifications of ASTM D1836 and contains at least 40 liquid...
Materials Safety Data Sheets: the basis for control of toxic chemicals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ketchen, E.E.; Porter, W.E.
1979-09-01
The Material Safety Data Sheets contained in this volume are the basis for the Toxic Chemical Control Program developed by the Industrial Hygiene Department, Health Division, ORNL. The three volumes are the update and expansion of ORNL/TM-5721 and ORNL/TM-5722 Material Safety Data Sheets: The Basis for Control of Toxic Chemicals, Volume I and Volume II. As such, they are a valuable adjunct to the data cards issued with specific chemicals. The chemicals are identified by name, stores catalog number where appropriate, and sequence numbers from the NIOSH Registry of Toxic Effects of Chemical Substances, 1977 Edition, if available. The datamore » sheets were developed and compiled to aid in apprising the employees of hazards peculiar to the handling and/or use of specific toxic chemicals. Space limitation necessitate the use of descriptive medical terms and toxicological abbreviations. A glossary and an abbreviation list were developed to define some of those sometimes unfamiliar terms and abbreviations. The page numbers are keyed to the catalog number in the chemical stores at ORNL.« less
NASA Technical Reports Server (NTRS)
Ohsaka, K.; Chung, S. K.; Rhim, W. K.; Johnson, W. L.; Peker, A.; Scruggs, D.
1997-01-01
The specific volumes of the Zr(41.2)Ti(3.8)Cu(2.5)Ni(10.0)Be(22.5) alloy as a function of temperature, T, are determined by employing an image digitizing technique and numerical calculation methods applied to the electrostatically levitated spherical alloy. The linear fitting of the volumes of the alloy in the liquid, V(sub l), glass, V(sub g) and crystalline V(sub c), states in the temperature ranges shown in parentheses are V(sub l)(T) = 0.1583 + 8.877 x 10(exp -6) T(cu cm/g) (700-1300 K);V(sub g)(T) = 0.1603 + 5.528 x 10(exp -6) T (400-550 K);V(sub c)(T) = 0.1583 + 6.21 x 10(exp -6)T(400-850 K). The average volume thermal expansion coefficients within the temperature ranges are determined to be 5.32, 3.39. and 3.83 x 10(exp -5) (1/K) for the liquid, glass, and crystalline states, respectively.
Materials Safety Data Sheets: the basis for control of toxic chemicals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ketchen, E.E.; Porter, W.E.
The Material Safety Data Sheets contained in this volume are the basis for the Toxic Chemical Control Program developed by the Industrial Hygiene Department, Health Division, ORNL. The three volumes are the update and expansion of ORNL/TM-5721 and ORNL/TM-5722 Material Safety Data Sheets: The Basis for Control of Toxic Chemicals, Volume I and Volume II. As such, they are a valuable adjunct to the data cards issued with specific chemicals. The chemicals are identified by name, stores catalog number where appropriate, and sequence numbers from the NIOSH Registry of Toxic Effects of Chemical Substances, 1977 Edition, if available. The datamore » sheets were developed and compiled to aid in apprising the employees of hazards peculiar to the handling and/or use of specific toxic chemicals. Space limitation necessitate the use of descriptive medical terms and toxicological abbreviations. A glossary and an abbreviation list were developed to define some of those sometimes unfamiliar terms and abbreviations. The page numbers are keyed to the catalog number in the chemical stores at ORNL.« less
Identifying with fictive characters: structural brain correlates of the personality trait ‘fantasy’
Hänggi, Jürgen; Jancke, Lutz
2014-01-01
The perception of oneself as absorbed in the thoughts, feelings and happenings of a fictive character (e.g. in a novel or film) as if the character’s experiences were one’s own is referred to as identification. We investigated whether individual variation in the personality trait of identification is associated with individual variation in the structure of specific brain regions, using surface and volume-based morphometry. The hypothesized regions of interest were selected on the basis of their functional role in subserving the cognitive processing domains considered important for identification (i.e. mental imagery, empathy, theory of mind and merging) and for the immersive experience called ‘presence’. Controlling for age, sex, whole-brain volume and other traits, identification covaried significantly with the left hippocampal volume, cortical thickness in the right anterior insula and the left dorsal medial prefrontal cortex, and with gray matter volume in the dorsolateral prefrontal cortex. These findings show that trait identification is associated with structural variation in specific brain regions. The findings are discussed in relation to the potential functional contribution of these regions to identification. PMID:24464847
Jamal, Muhammad Asghar; Rashad, Muhammad; Khosa, Muhammad Kaleem; Bhatti, Haq Nawaz
2015-04-15
Densities and ultrasonic velocity values for aqueous solutions of sodium saccharin (SS) has been measured as a function of concentration at 20.0-45.0 °C and atmospheric pressure using DSA-5000 M. The density and ultrasonic velocity values have been further used to calculate apparent molar volume, apparent specific volume, isentropic apparent molar compressibility and compressibility hydration numbers and reported. The values for apparent molar volume obtained at given temperatures showed negative deviations from Debye-Hückel limiting law and used as a direct measure of the ion-ion and ion-solvent interactions. The apparent specific volumes of the solute were calculated and it was found that these values of the investigated solutions lie on the borderline between the values reported for sweet substances. The sweetness response of the sweeteners is then explained in terms of their solution behaviours. Furthermore, the partial molar expansibility, its second derivative, (∂(2)V°/∂T(2)) as Hepler's constant and thermal expansion coefficient have been estimated. Copyright © 2014 Elsevier Ltd. All rights reserved.
Assessing the Use of Sunken Lanes for Water Retention in a Landscape
NASA Astrophysics Data System (ADS)
Zlatuška, Karel
2012-12-01
Newly-designed structures and landscaping elements are often used for flood protection. This article assesses the use of existing sunken lanes for retaining water in a landscape and the sedimentation of washed-off soil. The article also describes ways how to preserve or, at least minimally disrupt, existing biotopes and landscape segments. Geodetic data from one specific sunken lane in South Moravia in the Czech Republic were transferred to a digital terrain model; 9 models were subsequently generated, each with a different longitudinal sunken lane bed slope. Retention dams consisting of gabions were placed in them. The
State relations for a two-phase mixture of reacting explosives and applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kubota, Shiro; Saburi, Tei; Ogata, Yuji
2007-10-15
To assess the assumptions behind the two phase mixture rule for reacting explosives, the shock-to-detonation transition process was calculated for high explosives using a finite difference method. An ignition and growth model and the Jones-Wilkins-Lee (JWL) equations of state were employed. The simple mixture rule assumes that the reacting explosive is a simple mixture of the reactant and product components. Four different assumptions, such as that of thermal equilibrium and isotropy, were adopted to calculate the pressure. The main purpose of this paper is to present the answer to the question of why the numerical results of shock-initiation are insensitivemore » to the assumptions adopted. The equations of state for reactants and products were assessed by considering plots of the specific internal energy E and specific volume V. If the slopes of the constant-pressure lines for both components in the E-V plane are almost the same, it is demonstrated that the numerical results are insensitive to the assumptions adopted. We have found that the relation for the specific volumes of the two components can be approximately expressed by a single curve of the specific volume of the reactant vs that of the products. We discuss this relationship in terms of the results of the numerical simulation. (author)« less
Structural brain correlates of unconstrained motor activity in people with schizophrenia.
Farrow, Tom F D; Hunter, Michael D; Wilkinson, Iain D; Green, Russell D J; Spence, Sean A
2005-11-01
Avolition affects quality of life in chronic schizophrenia. We investigated the relationship between unconstrained motor activity and the volume of key executive brain regions in 16 male patients with schizophrenia. Wristworn actigraphy monitors were used to record motor activity over a 20 h period. Structural magnetic resonance imaging brain scans were parcellated and individual volumes for anterior cingulate cortex and dorsolateral prefrontal cortex extracted. Patients'total activity was positively correlated with volume of left anterior cingulate cortex. These data suggest that the volume of specific executive structures may affect (quantifiable) motor behaviours, having further implications for models of the 'will' and avolition.
Suicide rates and information seeking via search engines: A cross-national correlational approach.
Arendt, Florian
2018-09-01
The volume of Google searches for suicide-related terms is positively associated with suicide rates, but previous studies used data from specific, restricted geographical contexts, thus, limiting the generalizability of this finding. We investigated the correlation between suicide-related search volume and suicide rates of 50 nations from five continents. We found a positive correlation between suicide rates and search volume, even after controlling for the level of industrialization. Results give credence to the global existence of a correlation. However, the reason why suicide-related search volume is higher in countries with higher suicide rates is still unclear and up to future research.
Parametric evaluation of ball milling of SiC in water
NASA Technical Reports Server (NTRS)
Kiser, J. D.; Herbell, T. P.; Freedman, M. R.
1985-01-01
A statistically designed experiment was conducted to determine optimum conditions for ball milling alpha-SiC in water. The influence of pH adjustment, volume percent solids loading, and mill rotational speed on grinding effectiveness was examined. An equation defining the effect of those milling variables on specific surface area was obtained. The volume percent solids loading of the slurry had the greatest influence on the grinding effectiveness in terms of increase in specific surface area. As grinding effectiveness improved, mill and media wear also increased. Contamination was minimized by use of sintered alpha-SiC milling hardware.
Patterns of brain atrophy associated with episodic memory and semantic fluency decline in aging.
Pelletier, Amandine; Bernard, Charlotte; Dilharreguy, Bixente; Helmer, Catherine; Le Goff, Melanie; Chanraud, Sandra; Dartigues, Jean-François; Allard, Michèle; Amieva, Hélène; Catheline, Gwénaëlle
2017-03-09
The cerebral substratum of age-related cognitive decline was evaluated in an elderly-cohort followed for 12 years (n=306). Participants, free of dementia, received neuropsychological assessments every two years and an MRI exam at baseline and four years later. Cognitive decline was evaluated on two broadly used tests to detect dementia: the Free and Cued Selective Reminding Test (FCSRT), a verbal episodic memory task, and the Isaacs Set Test (IST), a semantic fluency task. Using voxel-based approach, the relationship between cognitive decline with 1/ baseline grey matter volumes and 2/ grey matter volume loss between the two scans was explored. Baseline volumes analysis revealed that FCSRT and IST declines were both associated with lower volumes of the medial temporal region. Volumes loss analysis confirmed that both declines are related to medial temporal lobe atrophy and revealed that FCSRT decline was specifically associated with atrophy of the posterior cingulate cortex whereas IST decline was specifically related to temporal pole atrophy. These results suggest that cognitive decline across aging is firstly related to structural modifications of the medial temporal lobe, followed by an atrophy in the posterior midline structures for episodic memory and an atrophy of the temporal pole for semantic fluency.
Sex differences and structural brain maturation from childhood to early adulthood.
Koolschijn, P Cédric M P; Crone, Eveline A
2013-07-01
Recent advances in structural brain imaging have demonstrated that brain development continues through childhood and adolescence. In the present cross-sectional study, structural MRI data from 442 typically developing individuals (range 8-30) were analyzed to examine and replicate the relationship between age, sex, brain volumes, cortical thickness and surface area. Our findings show differential patterns for subcortical and cortical areas. Analysis of subcortical volumes showed that putamen volume decreased with age and thalamus volume increased with age. Independent of age, males demonstrated larger amygdala and thalamus volumes compared to females. Cerebral white matter increased linearly with age, at a faster pace for females than males. Gray matter showed nonlinear decreases with age. Sex-by-age interactions were primarily found in lobar surface area measurements, with males demonstrating a larger cortical surface up to age 15, while cortical surface in females remained relatively stable with increasing age. The current findings replicate some, but not all prior reports on structural brain development, which calls for more studies with large samples, replications, and specific tests for brain structural changes. In addition, the results point toward an important role for sex differences in brain development, specifically during the heterogeneous developmental phase of puberty. Copyright © 2013 Elsevier Ltd. All rights reserved.
Daniels, J K; Frewen, P; Theberge, J; Lanius, R A
2016-03-01
One factor potentially contributing to the heterogeneity of previous results on structural grey matter alterations in adult participants suffering from post-traumatic stress disorder (PTSD) is the varying levels of dissociative symptomatology. The aim of this study was therefore to test whether the recently defined dissociative subtype of PTSD characterized by symptoms of depersonalization and derealization is characterized by specific differences in volumetric brain morphology. Whole-brain MRI data were acquired for 59 patients with PTSD. Voxel-based morphometry was carried out to test for group differences between patients classified as belonging (n = 15) vs. not belonging (n = 44) to the dissociative subtype of PTSD. The correlation between dissociation (depersonalization/derealization) severity and grey matter volume was computed. Patients with PTSD classified as belonging to the dissociative subtype exhibited greater grey matter volume in the right precentral and fusiform gyri as well as less volume in the right inferior temporal gyrus. Greater dissociation severity was associated with greater volume in the right middle frontal gyrus. The results of this first whole-brain investigation of specific grey matter volume in dissociative subtype PTSD indentified structural aberrations in regions subserving the processing and regulation of emotional arousal. These might constitute characteristic biomarkers for the dissociative subtype PTSD. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Vuoksimaa, Eero; Panizzon, Matthew S; Chen, Chi-Hua; Fiecas, Mark; Eyler, Lisa T; Fennema-Notestine, Christine; Hagler, Donald J; Fischl, Bruce; Franz, Carol E; Jak, Amy; Lyons, Michael J; Neale, Michael C; Rinker, Daniel A; Thompson, Wesley K; Tsuang, Ming T; Dale, Anders M; Kremen, William S
2015-08-01
Total gray matter volume is associated with general cognitive ability (GCA), an association mediated by genetic factors. It is expectable that total neocortical volume should be similarly associated with GCA. Neocortical volume is the product of thickness and surface area, but global thickness and surface area are unrelated phenotypically and genetically in humans. The nature of the genetic association between GCA and either of these 2 cortical dimensions has not been examined. Humans possess greater cognitive capacity than other species, and surface area increases appear to be the primary driver of the increased size of the human cortex. Thus, we expected neocortical surface area to be more strongly associated with cognition than thickness. Using multivariate genetic analysis in 515 middle-aged twins, we demonstrated that both the phenotypic and genetic associations between neocortical volume and GCA are driven primarily by surface area rather than thickness. Results were generally similar for each of 4 specific cognitive abilities that comprised the GCA measure. Our results suggest that emphasis on neocortical surface area, rather than thickness, could be more fruitful for elucidating neocortical-GCA associations and identifying specific genes underlying those associations. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Xu, Xiaojiang; Rioux, Timothy P.; MacLeod, Tynan; Patel, Tejash; Rome, Maxwell N.; Potter, Adam W.
2017-03-01
The purpose of this paper is to develop a database of tissue composition, distribution, volume, surface area, and skin thickness from anatomically correct human models, the virtual family. These models were based on high-resolution magnetic resonance imaging (MRI) of human volunteers, including two adults (male and female) and two children (boy and girl). In the segmented image dataset, each voxel is associated with a label which refers to a tissue type that occupies up that specific cubic millimeter of the body. The tissue volume was calculated from the number of the voxels with the same label. Volumes of 24 organs in body and volumes of 7 tissues in 10 specific body regions were calculated. Surface area was calculated from the collection of voxels that are touching the exterior air. Skin thicknesses were estimated from its volume and surface area. The differences between the calculated and original masses were about 3 % or less for tissues or organs that are important to thermoregulatory modeling, e.g., muscle, skin, and fat. This accurate database of body tissue distributions and geometry is essential for the development of human thermoregulatory models. Data derived from medical imaging provide new effective tools to enhance thermal physiology research and gain deeper insight into the mechanisms of how the human body maintains heat balance.
Survey of college students' MP3 listening: Habits, safety issues, attitudes, and education.
Hoover, Alicia; Krishnamurti, Sridhar
2010-06-01
To survey listening habits and attitudes of typical college students who use MP3 players and to investigate possible safety issues related to MP3 player listening. College students who were frequent MP3 player users (N = 428) filled out a 30-item online survey. Specific areas probed by the present survey included frequency and duration of MP3 player use, MP3 player volume levels used, types of earphones used, typical environments in which MP3 player was worn, specific activities related to safety while listening to MP3 players, and attitudes toward MP3 player use. The majority of listeners wore MP3 players for less than 2 hr daily at safe volume levels. About one third of respondents reported being distracted while wearing an MP3 player, and more than one third of listeners experienced soreness in their ears after a listening session. About one third of respondents reported occasionally using their MP3 players at maximum volume levels. Listeners indicated willingness to (a) reduce volume levels, (b) decrease listening duration, and (c) buy specialized earphones to conserve their hearing. The study found concerns regarding the occasional use of MP3 players at full volume and reduced environmental awareness among some college student users.
Preoperative computer simulation for planning of vascular access surgery in hemodialysis patients.
Zonnebeld, Niek; Huberts, Wouter; van Loon, Magda M; Delhaas, Tammo; Tordoir, Jan H M
2017-03-06
The arteriovenous fistula (AVF) is the preferred vascular access for hemodialysis patients. Unfortunately, 20-40% of all constructed AVFs fail to mature (FTM), and are therefore not usable for hemodialysis. AVF maturation importantly depends on postoperative blood volume flow. Predicting patient-specific immediate postoperative flow could therefore support surgical planning. A computational model predicting blood volume flow is available, but the effect of blood flow predictions on the clinical endpoint of maturation (at least 500 mL/min blood volume flow, diameter of the venous cannulation segment ≥4 mm) remains undetermined. A multicenter randomized clinical trial will be conducted in which 372 patients will be randomized (1:1 allocation ratio) between conventional healthcare and computational model-aided decision making. All patients are extensively examined using duplex ultrasonography (DUS) during preoperative assessment (12 venous and 11 arterial diameter measurements; 3 arterial volume flow measurements). The computational model will predict patient-specific immediate postoperative blood volume flows based on this DUS examination. Using these predictions, the preferred AVF configuration is recommended for the individual patient (radiocephalic, brachiocephalic, or brachiobasilic). The primary endpoint is FTM rate at six weeks in both groups, secondary endpoints include AVF functionality and patency rates at 6 and 12 months postoperatively. ClinicalTrials.gov (NCT02453412), and ToetsingOnline.nl (NL51610.068.14).
Optical Automatic Car Identification (OACI) : Volume 1. Advanced System Specification.
DOT National Transportation Integrated Search
1978-12-01
A performance specification is provided in this report for an Optical Automatic Car Identification (OACI) scanner system which features 6% improved readability over existing industry scanner systems. It also includes the analysis and rationale which ...
The cavity heat pipe Stirling receiver for space solar dynamics
NASA Technical Reports Server (NTRS)
Kesseli, James B.; Lacy, Dovie E.
1989-01-01
The receiver/storage unit for the low-earth-orbiting Stirling system is discussed. The design, referred to as the cavity heat pipe (CHP), has been optimized for minimum specific mass and volume width. A specific version of this design at the 7-kWe level has been compared to the space station Brayton solar dynamic design. The space station design utilizes a eutectic mixture of LiF and CaF2. Using the same phase change material, the CHP has been shown to have a specific mass of 40 percent and a volume of 5 percent of that of the space station Brayton at the same power level. Additionally, it complements the free-piston Stirling engine in that it also maintains a relatively flat specific mass down to at least 1 kWe. The technical requirements, tradeoff studies, critical issues, and critical technology experiments are discussed.
Tumor volume in insignificant prostate cancer: increasing threshold gains increasing risk.
Schiffmann, Jonas; Connan, Judith; Salomon, Georg; Boehm, Katharina; Beyer, Burkhard; Schlomm, Thorsten; Tennstedt, Pierre; Sauter, Guido; Karakiewicz, Pierre I; Graefen, Markus; Huland, Hartwig
2015-01-01
An increased tumor volume threshold (<2.5 ml) is suggested to define insignificant prostate cancer (iPCa). We hypothesize that an increasing tumor volume within iPCa patients increases the risk of biochemical recurrence (BCR) after radical prostatectomy (RP). We relied on RP patients treated between 1992 and 2008. Multivariable Cox regression analyses predicting BCR within patients harboring favorable pathological characteristics (≤pT2, pN0/Nx, Gleason 3 + 3). Kaplan-Meier analysis was performed for BCR-free survival within iPCa patients (≤pT2, pN0/Nx, Gleason 3 + 3, tumor volume: <0.5 vs. 0.5-2.49 ml). From 1,829 patients, 141 (7.7%) and 310 (16.9%) harbored iPCa (tumor volume: <0.5 vs. 0.5-2.49 ml), respectively. Of those, 21 (14.9%) versus 31 (10.0%) had PSA >10 ng/ml. Tumor volume achieved independent predictor status for BCR. Specifically, iPCa patients with increasing tumor volume (0.5-2.49 ml) were at higher risk of BCR after RP than those with tumor volume <0.5 ml (HR: 8.8, 95% CI: 1.2-65.9, P = 0.04). Kaplan-Meier analysis recorded superior BCR-free survival in iPCa patients with lower tumor volume (<0.5 ml) (log-rank P = 0.009). The 10-year cancer-specific death rate was 0 versus 0.5%. Contemporary iPCa definition incorporates intermediate and high-risk patients (PSA: 10-20 and >20 ng/ml). Despite most favorable pathological characteristics, iPCa patients are not devoid of BCR after RP. Moreover, iPCa patients were at higher risk of BCR, when increasing tumor volume up to 2.49 ml was at play. Taken together the contemporary concept of iPCa is suboptimal. Especially, an increased tumor volume threshold for defining iPCa cannot be recommended according to our data. Clinicians might take these considerations into account during decision-making process. © 2014 Wiley Periodicals, Inc.
Fibla, Juan J; Brunelli, Alessandro; Allen, Mark S; Wigle, Dennis; Shen, Robert; Nichols, Francis; Deschamps, Claude; Cassivi, Stephen D
2015-02-01
Our objective was to evaluate whether the number and volume of surgical lung biopsies (SLB) influence the diagnosis of diffuse interstitial lung disease (ILD). Retrospective study of SLB for suspected ILD in patients from the Mayo Clinic from January 2002 to January 2010. Data were collected in the institution and analyzed. 311 patients were studied. Mean number of biopsies was 2.05 (SD 0.6); 1 biopsy in 50 (16%), 2 in 198 (63.7%), 3 in 59 (19%) and 4 in 4 (1.3%). Histopathologic diagnosis was: definitive (specific): 232 (74.6%), descriptive (non-specific): 76 (24.4%), no diagnosis: 3 (1%). After excluding patients without diagnosis (n=3), there were 50 patients with only 1 biopsy, 196 with 2 and 62 with 3 or 4; the definitive diagnostic yield was similar in all 3 groups (37/50; 74%, 150/196; 77%, and 45/62; 73%) (Chi-square, p value 0.8). The propensity score analysis between patients with 1 SLB and patients with more than 1 SLB also showed no difference in diagnostic yield. Regarding the volume of biopsies, mean total volume was 34.4 cm(3) (SD 46): 41.2 cm(3) (3 cases) in patients with no diagnosis; 33.6 cm(3) (232 cases, SD 47) in patients with specific diagnosis; and 36.6 cm(3) (76 cases, SD 44) in patients with descriptive diagnosis. Biopsy volume had no influence on histopathology yield (ANOVA, p value .8). The number and volume of the biopsy specimens in SLB did not seem to influence diagnosis. Based on our results, we believe a single sample from a representative area may be sufficient for diagnosis. Randomized prospective trials should be performed to optimize SLB for ILD. Copyright © 2014 SEPAR. Published by Elsevier Espana. All rights reserved.
Jonker, Jacqueline T; de Mol, Pieter; de Vries, Suzanna T; Widya, Ralph L; Hammer, Sebastiaan; van Schinkel, Linda D; van der Meer, Rutger W; Gans, Rijk O B; Webb, Andrew G; Kan, Hermien E; de Koning, Eelco J P; Bilo, Henk J G; Lamb, Hildo J
2013-11-01
To prospectively assess the effects of an exercise intervention on organ-specific fat accumulation and cardiac function in type 2 diabetes mellitus. Written informed consent was obtained from all participants, and the study protocol was approved by the medical ethics committee. The study followed 12 patients with type 2 diabetes mellitus (seven men; mean age, 46 years ± 2 [standard error]) before and after 6 months of moderate-intensity exercise, followed by a high-altitude trekking expedition with exercise of long duration. Abdominal, epicardial, and paracardial fat volume were measured by using magnetic resonance (MR) imaging. Cardiac function was quantified with cardiac MR, and images were analyzed by a researcher who was supervised by a senior researcher (4 and 21 years of respective experience in cardiac MR). Hepatic, myocardial, and intramyocellular triglyceride (TG) content relative to water were measured with proton MR spectroscopy at 1.5 and 7 T. Two-tailed paired t tests were used for statistical analysis. Exercise reduced visceral abdominal fat volume from 348 mL ± 57 to 219 mL ± 33 (P < .01), and subcutaneous abdominal fat volume remained unchanged (P = .9). Exercise decreased hepatic TG content from 6.8% ± 2.3 to 4.6% ± 1.6 (P < .01) and paracardial fat volume from 4.6 mL ± 0.9 to 3.7 mL ± 0.8 (P = .02). Exercise did not change epicardial fat volume (P = .9), myocardial TG content (P = .9), intramyocellular lipid content (P = .3), or cardiac function (P = .5). A 6-month exercise intervention in type 2 diabetes mellitus decreased hepatic TG content and visceral abdominal and paracardial fat volume, which are associated with increased cardiovascular risk, but cardiac function was unaffected. Tissue-specific exercise-induced changes in body fat distribution in type 2 diabetes mellitus were demonstrated in this study. RSNA, 2013
2013-01-01
Background Drop drying is a key factor in a wide range of technical applications, including spotted microarrays. The applied nL liquid volume provides specific reaction conditions for the immobilization of probe molecules to a chemically modified surface. Results We investigated the influence of nL and μL liquid drop volumes on the process of probe immobilization and compare the results obtained to the situation in liquid solution. In our data, we observe a strong relationship between drop drying effects on immobilization and surface chemistry. In this work, we present results on the immobilization of dye labeled 20mer oligonucleotides with and without an activating 5′-aminoheptyl linker onto a 2D epoxysilane and a 3D NHS activated hydrogel surface. Conclusions Our experiments identified two basic processes determining immobilization. First, the rate of drop drying that depends on the drop volume and the ambient relative humidity. Oligonucleotides in a dried spot react unspecifically with the surface and long reaction times are needed. 3D hydrogel surfaces allow for immobilization in a liquid environment under diffusive conditions. Here, oligonucleotide immobilization is much faster and a specific reaction with the reactive linker group is observed. Second, the effect of increasing probe concentration as a result of drop drying. On a 3D hydrogel, the increasing concentration of probe molecules in nL spotting volumes accelerates immobilization dramatically. In case of μL volumes, immobilization depends on whether the drop is allowed to dry completely. At non-drying conditions, very limited immobilization is observed due to the low oligonucleotide concentration used in microarray spotting solutions. The results of our study provide a general guideline for microarray assay development. They allow for the initial definition and further optimization of reaction conditions for the immobilization of oligonucleotides and other probe molecule classes to different surfaces in dependence of the applied spotting and reaction volume. PMID:23758982
Roth, Timothy C; Brodin, Anders; Smulders, Tom V; LaDage, Lara D; Pravosudov, Vladimir V
2010-03-27
A well-developed spatial memory is important for many animals, but appears especially important for scatter-hoarding species. Consequently, the scatter-hoarding system provides an excellent paradigm in which to study the integrative aspects of memory use within an ecological and evolutionary framework. One of the main tenets of this paradigm is that selection for enhanced spatial memory for cache locations should specialize the brain areas involved in memory. One such brain area is the hippocampus (Hp). Many studies have examined this adaptive specialization hypothesis, typically relating spatial memory to Hp volume. However, it is unclear how the volume of the Hp is related to its function for spatial memory. Thus, the goal of this article is to evaluate volume as a main measurement of the degree of morphological and physiological adaptation of the Hp as it relates to memory. We will briefly review the evidence for the specialization of memory in food-hoarding animals and discuss the philosophy behind volume as the main currency. We will then examine the problems associated with this approach, attempting to understand the advantages and limitations of using volume and discuss alternatives that might yield more specific hypotheses. Overall, there is strong evidence that the Hp is involved in the specialization of spatial memory in scatter-hoarding animals. However, volume may be only a coarse proxy for more relevant and subtle changes in the structure of the brain underlying changes in behaviour. To better understand the nature of this brain/memory relationship, we suggest focusing on more specific and relevant features of the Hp, such as the number or size of neurons, variation in connectivity depending on dendritic and axonal arborization and the number of synapses. These should generate more specific hypotheses derived from a solid theoretical background and should provide a better understanding of both neural mechanisms of memory and their evolution.
NASA Technical Reports Server (NTRS)
1974-01-01
The specifications for the Earth Observatory Satellite (EOS) peculiar spacecraft segment and associated subsystems and modules are presented. The specifications considered include the following: (1) wideband communications subsystem module, (2) mission peculiar software, (3) hydrazine propulsion subsystem module, (4) solar array assembly, and (5) the scanning spectral radiometer.
Thyroid Volume and Its Relation to Anthropometric Measures in a Healthy Cuban Population
Turcios, Silvia; Lence-Anta, Juan J.; Santana, Jose-Luis; Pereda, Celia M.; Velasco, Milagros; Chappe, Mae; Infante, Idalmis; Bustillo, Marlene; García, Anabel; Clero, Enora; Maillard, Stephane; Rodriguez, Regla; Xhaard, Constance; Ren, Yan; Rubino, Carole; Ortiz, Rosa M.; de Vathaire, Florent
2015-01-01
Objectives The aim of this study was to describe the thyroid volume in healthy adults by ultrasound and to correlate this volume with some anthropometric measures and other differentiated thyroid cancer risk factors. Study Design Thyroid volume and anthropometric measures were recorded in a sample of 100 healthy adults, including 21 men and 79 women aged 18-50 years, living in a non-iodine-deficient area of Havana city. Results The average thyroid volume was 6.6 ± 0.26 ml; it was higher in men (7.3 ml) than in women (6.4 ml; p = 0.15). In the univariate analysis, thyroid volume was correlated with all anthropometric measures, but in the multivariate analysis, body surface area was found to be the only significant anthropometric parameter. Thyroid volume was also higher in current or former smokers and in persons with blood group AB or B. Conclusion Specific reference values of thyroid volume as a function of body surface area could be used for evaluating thyroid volume in clinical practice. The relation between body surface area and thyroid volume is coherent with what is known about the relation of thyroid volume to thyroid cancer risk, but the same is not true about the relation between thyroid volume and smoking habit. PMID:25960963
Fraguas, David; Díaz-Caneja, Covadonga M; Pina-Camacho, Laura; Janssen, Joost; Arango, Celso
2016-06-01
Studies on longitudinal brain volume changes in patients with early-onset psychosis (EOP) are particularly valuable for understanding the neurobiological basis of brain abnormalities associated with psychosis. However, findings have not been consistent across studies in this population. We aimed to conduct a meta-analysis on progressive brain volume changes in children and adolescents with EOP. A systematic literature search of magnetic resonance imaging (MRI) studies comparing longitudinal brain volume changes in children and adolescents with EOP and healthy controls was conducted. The annualized rates of relative change in brain volume by region of interest (ROI) were used as raw data for the meta-analysis. The effect of age, sex, duration of illness, and specific diagnosis on volume change was also evaluated. Five original studies with 156 EOP patients (mean age at baseline MRI in the five studies ranged from 13.3 to 16.6years, 67.31% males) and 163 age- and sex-matched healthy controls, with a mean duration of follow-up of 2.46years (range 2.02-3.40), were included. Frontal gray matter (GM) was the only region in which significant differences in volume change over time were found between patients and controls (Hedges' g -0.435, 95% confidence interval (CI): -0.678 to -0.193, p<0.001). Younger age at baseline MRI was associated with greater loss of temporal GM volume over time in patients as compared with controls (p=0.005). Within patients, a diagnosis of schizophrenia was related to greater occipital GM volume loss over time (p=0.001). Compared with healthy individuals, EOP patients show greater progressive frontal GM loss over the first few years after illness onset. Age at baseline MRI and diagnosis of schizophrenia appear to be significant moderators of particular specific brain volume changes. Copyright © 2014 Elsevier B.V. All rights reserved.
Dhikav, Vikas; Duraiswamy, Sharmila; Anand, Kuljeet Singh
2017-01-01
Hippocampus undergoes atrophy in patients with Alzheimer's disease (AD). Calculation of hippocampal volumes can be done by a variety of methods using T1-weighted images of magnetic resonance imaging (MRI) of the brain. Medial temporal lobes atrophy (MTL) can be rated visually using T1-weighted MRI brain images. The present study was done to see if any correlation existed between hippocampal volumes and visual rating scores of the MTL using Scheltens Visual Rating Method. We screened 84 subjects presented to the Department of Neurology of a Tertiary Care Hospital and enrolled forty subjects meeting the National Institute of Neurological and Communicative Disorders and Stroke, AD related Disease Association criteria. Selected patients underwent MRI brain and T1-weighted images in a plane perpendicular to long axis of hippocampus were obtained. Hippocampal volumes were calculated manually using a standard protocol. The calculated hippocampal volumes were correlated with Scheltens Visual Rating Method for Rating MTL. A total of 32 cognitively normal age-matched subjects were selected to see the same correlation in the healthy subjects as well. Sensitivity and specificity of both methods was calculated and compared. There was an insignificant correlation between the hippocampal volumes and MTL rating scores in cognitively normal elderly ( n = 32; Pearson Correlation coefficient = 0.16, P > 0.05). In the AD Group, there was a moderately strong correlation between measured hippocampal volumes and MTL Rating (Pearson's correlation coefficient = -0.54; P < 0.05. There was a moderately strong correlation between hippocampal volume and Mini-Mental Status Examination in the AD group. Manual delineation was superior compared to the visual method ( P < 0.05). Good correlation was present between manual hippocampal volume measurements and MTL scores. Sensitivity and specificity of manual measurement of hippocampus was higher compared to visual rating scores for MTL in patients with AD.
Dhikav, Vikas; Duraiswamy, Sharmila; Anand, Kuljeet Singh
2017-01-01
Introduction: Hippocampus undergoes atrophy in patients with Alzheimer's disease (AD). Calculation of hippocampal volumes can be done by a variety of methods using T1-weighted images of magnetic resonance imaging (MRI) of the brain. Medial temporal lobes atrophy (MTL) can be rated visually using T1-weighted MRI brain images. The present study was done to see if any correlation existed between hippocampal volumes and visual rating scores of the MTL using Scheltens Visual Rating Method. Materials and Methods: We screened 84 subjects presented to the Department of Neurology of a Tertiary Care Hospital and enrolled forty subjects meeting the National Institute of Neurological and Communicative Disorders and Stroke, AD related Disease Association criteria. Selected patients underwent MRI brain and T1-weighted images in a plane perpendicular to long axis of hippocampus were obtained. Hippocampal volumes were calculated manually using a standard protocol. The calculated hippocampal volumes were correlated with Scheltens Visual Rating Method for Rating MTL. A total of 32 cognitively normal age-matched subjects were selected to see the same correlation in the healthy subjects as well. Sensitivity and specificity of both methods was calculated and compared. Results: There was an insignificant correlation between the hippocampal volumes and MTL rating scores in cognitively normal elderly (n = 32; Pearson Correlation coefficient = 0.16, P > 0.05). In the AD Group, there was a moderately strong correlation between measured hippocampal volumes and MTL Rating (Pearson's correlation coefficient = −0.54; P < 0.05. There was a moderately strong correlation between hippocampal volume and Mini-Mental Status Examination in the AD group. Manual delineation was superior compared to the visual method (P < 0.05). Conclusions: Good correlation was present between manual hippocampal volume measurements and MTL scores. Sensitivity and specificity of manual measurement of hippocampus was higher compared to visual rating scores for MTL in patients with AD. PMID:28298839
Low-intensity daily walking activity is associated with hippocampal volume in older adults.
Varma, Vijay R; Chuang, Yi-Fang; Harris, Gregory C; Tan, Erwin J; Carlson, Michelle C
2015-05-01
Hippocampal atrophy is associated with memory impairment and dementia and serves as a key biomarker in the preclinical stages of Alzheimer's disease. Physical activity, one of the most promising behavioral interventions to prevent or delay cognitive decline, has been shown to be associated with hippocampal volume; specifically increased aerobic activity and fitness may have a positive effect on the size of the hippocampus. The majority of older adults, however, are sedentary and have difficulty initiating and maintaining exercise programs. A modestly more active lifestyle may nonetheless be beneficial. This study explored whether greater objectively measured daily walking activity was associated with larger hippocampal volume. We additionally explored whether greater low-intensity walking activity, which may be related to leisure-time physical, functional, and social activities, was associated with larger hippocampal volume independent of exercise and higher-intensity walking activity. Segmentation of hippocampal volumes was performed using Functional Magnetic Resonance Imaging of the Brain's Software Library (FSL), and daily walking activity was assessed using a step activity monitor on 92, nondemented, older adult participants. After controlling for age, education, body mass index, cardiovascular disease risk factors, and the Mini Mental State Exam, we found that a greater amount, duration, and frequency of total daily walking activity were each associated with larger hippocampal volume among older women, but not among men. These relationships were specific to hippocampal volume, compared with the thalamus, used as a control brain region, and remained significant for low-intensity walking activity, independent of moderate- to vigorous-intensity activity and self-reported exercise. This is the first study, to our knowledge, to explore the relationship between objectively measured daily walking activity and hippocampal volume in an older adult population. Findings suggest the importance of examining whether increasing nonexercise, lifestyle physical activities may produce measurable cognitive benefits and affect hippocampal volume through molecular pathways unique to those related to moderate-intensity exercise. © 2014 Wiley Periodicals, Inc.
Rofes, L; Arreola, V; Mukherjee, R; Clavé, P
2014-09-01
Oropharyngeal dysphagia (OD) is an underdiagnosed digestive disorder that causes severe nutritional and respiratory complications. Our aim was to determine the accuracy of the Eating Assessment Tool (EAT-10) and the Volume-Viscosity Swallow Test (V-VST) for clinical evaluation of OD. We studied 120 patients with swallowing difficulties and 14 healthy subjects. OD was evaluated by the 10-item screening questionnaire EAT-10 and the bedside method V-VST, videofluoroscopy (VFS) being the reference standard. The V-VST is an effort test that uses boluses of different volumes and viscosities to identify clinical signs of impaired efficacy (impaired labial seal, piecemeal deglutition, and residue) and impaired safety of swallow (cough, voice changes, and oxygen desaturation ≥3%). Discriminating ability was assessed by the AUC of the ROC curve and sensitivity and specificity values. According to VFS, prevalence of OD was 87%, 75.6% with impaired efficacy and 80.9% with impaired safety of swallow including 17.6% aspirations. The EAT-10 showed a ROC AUC of 0.89 for OD with an optimal cut-off at 2 (0.89 sensitivity and 0.82 specificity). The V-VST showed 0.94 sensitivity and 0.88 specificity for OD, 0.79 sensitivity and 0.75 specificity for impaired efficacy, 0.87 sensitivity and 0.81 specificity for impaired safety, and 0.91 sensitivity and 0.28 specificity for aspirations. Clinical methods for screening (EAT-10) and assessment (V-VST) of OD offer excellent psychometric proprieties that allow adequate management of OD. Their universal application among at-risk populations will improve the identification of patients with OD at risk for malnutrition and aspiration pneumonia. © 2014 The Authors. Neurogastroenterology & Motility published by John Wiley & Sons Ltd.
Rofes, L; Arreola, V; Mukherjee, R; Clavé, P
2014-01-01
Background Oropharyngeal dysphagia (OD) is an underdiagnosed digestive disorder that causes severe nutritional and respiratory complications. Our aim was to determine the accuracy of the Eating Assessment Tool (EAT-10) and the Volume-Viscosity Swallow Test (V-VST) for clinical evaluation of OD. Methods We studied 120 patients with swallowing difficulties and 14 healthy subjects. OD was evaluated by the 10-item screening questionnaire EAT-10 and the bedside method V-VST, videofluoroscopy (VFS) being the reference standard. The V-VST is an effort test that uses boluses of different volumes and viscosities to identify clinical signs of impaired efficacy (impaired labial seal, piecemeal deglutition, and residue) and impaired safety of swallow (cough, voice changes, and oxygen desaturation ≥3%). Discriminating ability was assessed by the AUC of the ROC curve and sensitivity and specificity values. Key Results According to VFS, prevalence of OD was 87%, 75.6% with impaired efficacy and 80.9% with impaired safety of swallow including 17.6% aspirations. The EAT-10 showed a ROC AUC of 0.89 for OD with an optimal cut-off at 2 (0.89 sensitivity and 0.82 specificity). The V-VST showed 0.94 sensitivity and 0.88 specificity for OD, 0.79 sensitivity and 0.75 specificity for impaired efficacy, 0.87 sensitivity and 0.81 specificity for impaired safety, and 0.91 sensitivity and 0.28 specificity for aspirations. Conclusions & Inferences Clinical methods for screening (EAT-10) and assessment (V-VST) of OD offer excellent psychometric proprieties that allow adequate management of OD. Their universal application among at-risk populations will improve the identification of patients with OD at risk for malnutrition and aspiration pneumonia. PMID:24909661
Development of Metabolic Function Biomarkers in the Common Marmoset, Callithrix jacchus
Ziegler, Toni E.; Colman, Ricki J.; Tardif, Suzette D.; Sosa, Megan E.; Wegner, Fredrick H.; Wittwer, Daniel J.; Shrestha, Hemanta
2013-01-01
Metabolic assessment of a nonhuman primate model of metabolic syndrome and obesity requires the necessary biomarkers specific to the species. While the rhesus monkey has a number of specific assays for assessing metabolic syndrome, the marmoset does not. Furthermore, the common marmoset (Callithrix jacchus) has a small blood volume that necessitates using a single blood volume for multiple analyses. The common marmoset holds a great potential as an alternative primate model for the study of human disease but assay methods need to be developed and validated for the biomarkers of metabolic syndrome. Here we report on the adaptation, development and validation of commercially available immunoassays for common marmoset samples in small volumes. We have performed biological validations for insulin, adiponectin, leptin, and ghrelin to demonstrate the use of these biomarkers in examining metabolic syndrome and other related diseases in the common marmoset. PMID:23447060
Examination of simplified travel demand model. [Internal volume forecasting model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, R.L. Jr.; McFarlane, W.J.
1978-01-01
A simplified travel demand model, the Internal Volume Forecasting (IVF) model, proposed by Low in 1972 is evaluated as an alternative to the conventional urban travel demand modeling process. The calibration of the IVF model for a county-level study area in Central Wisconsin results in what appears to be a reasonable model; however, analysis of the structure of the model reveals two primary mis-specifications. Correction of the mis-specifications leads to a simplified gravity model version of the conventional urban travel demand models. Application of the original IVF model to ''forecast'' 1960 traffic volumes based on the model calibrated for 1970more » produces accurate estimates. Shortcut and ad hoc models may appear to provide reasonable results in both the base and horizon years; however, as shown by the IVF mode, such models will not always provide a reliable basis for transportation planning and investment decisions.« less
Cantero, Jose L; Iglesias, Juan E; Van Leemput, Koen; Atienza, Mercedes
2016-09-01
Evidence suggests a link between the presence of subjective memory complaints (SMC) and lower volume of the hippocampus, one of the first regions to show neuropathological lesions in Alzheimer's disease. However, it remains unknown whether this pattern of hippocampal atrophy is regionally specific and whether SMC are also paralleled by changes in peripheral levels of amyloid-beta (Aβ). The volume of hippocampal subregions and plasma Aβ levels were cross-sectionally compared between elderly individuals with (SMC(+); N = 47) and without SMC (SMC(-); N = 48). Significant volume differences in hippocampal subregions were further correlated with plasma Aβ levels and with objective memory performance. Individuals with SMC exhibited significantly higher Aβ1-42 concentrations and lower volumes of CA1, CA4, dentate gyrus, and molecular layer compared with SMC(-) participants. Regression analyses further showed significant associations between lower volume of the dentate gyrus and both poorer memory performance and higher plasma Aβ1-42 levels in SMC(+) participants. The presence of SMC, lower volumes of specific hippocampal regions, and higher plasma Aβ1-42 levels could be conditions associated with aging vulnerability. If such associations are confirmed in longitudinal studies, the combination may be markers recommending clinical follow-up in nondemented older adults. © The Author 2016. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Ribeiro, Luís Gustavo; Busatto, Geraldo
2016-01-01
ABSTRACT Voxel-based morphometry (VBM) is a useful approach for investigating neurostructural brain changes in dementia. We systematically reviewed VBM studies of Alzheimer's disease (AD) and mild cognitive impairment (MCI), specifically focusing on grey matter (GM) atrophy in the frontal lobe. Methods: Two searches were performed on the Pubmed database. A set of exclusion criteria was applied to ensure the selection of only VBM studies that directly investigated GM volume abnormalities in AD and/or MCI patients compared to cognitively normal controls. Results: From a total of 46 selected articles, 35 VBM studies reported GM volume reductions in the frontal lobe. The frontal subregions, where most of the volume reductions were reported, included the inferior, superior and middle frontal gyri, as well as the anterior cingulate gyrus. We also found studies in which reduced frontal GM was detected in MCI patients who converted to AD. In a minority of studies, correlations between frontal GM volumes and behavioural changes or cognitive deficits in AD patients were investigated, with variable findings. Conclusion: Results of VBM studies indicate that the frontal lobe should be regarded as an important brain area when investigating GM volume deficits in association with AD. Frontal GM loss might not be a feature specific to late AD only. Future VBM studies involving large AD samples are warranted to further investigate correlations between frontal volume deficits and both cognitive impairment and neuropsychiatric symptoms. PMID:29213441
Hubbard, Logan; Lipinski, Jerry; Ziemer, Benjamin; Malkasian, Shant; Sadeghi, Bahman; Javan, Hanna; Groves, Elliott M; Dertli, Brian; Molloi, Sabee
2018-01-01
Purpose To retrospectively validate a first-pass analysis (FPA) technique that combines computed tomographic (CT) angiography and dynamic CT perfusion measurement into one low-dose examination. Materials and Methods The study was approved by the animal care committee. The FPA technique was retrospectively validated in six swine (mean weight, 37.3 kg ± 7.5 [standard deviation]) between April 2015 and October 2016. Four to five intermediate-severity stenoses were generated in the left anterior descending artery (LAD), and 20 contrast material-enhanced volume scans were acquired per stenosis. All volume scans were used for maximum slope model (MSM) perfusion measurement, but only two volume scans were used for FPA perfusion measurement. Perfusion measurements in the LAD, left circumflex artery (LCx), right coronary artery, and all three coronary arteries combined were compared with microsphere perfusion measurements by using regression, root-mean-square error, root-mean-square deviation, Lin concordance correlation, and diagnostic outcomes analysis. The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were also determined. Results FPA and MSM perfusion measurements (P FPA and P MSM ) in all three coronary arteries combined were related to reference standard microsphere perfusion measurements (P MICRO ), as follows: P FPA_COMBINED = 1.02 P MICRO_COMBINED + 0.11 (r = 0.96) and P MSM_COMBINED = 0.28 P MICRO_COMBINED + 0.23 (r = 0.89). The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were 10.8 and 17.8 mGy, respectively. Conclusion The FPA technique was retrospectively validated in a swine model and has the potential to be used for accurate, low-dose vessel-specific morphologic and physiologic assessment of coronary artery disease. © RSNA, 2017.
Alcázar, J L; Díaz, L; Flórez, P; Guerriero, S; Jurado, M
2013-08-01
To assess the feasibility of a specific training program for ultrasound diagnosis of adnexal masses. A 2-month intensive training program was developed. The program protocol consisted of a 1-day intensive theoretical course focused on clinical and sonographic issues related to adnexal masses and ovarian cancer, followed by a 4-week real-time ultrasound training program in a tertiary center (25-30 adnexal masses evaluated per month) and a final 4-week period for offline assessment of three-dimensional (3D) volumes from adnexal masses. In this final period, each trainee evaluated five sets of 100 3D volumes. 3D volumes contained gray-scale and power Doppler information, and the trainee was provided with clinical data for each case (patient age, menopausal status and reported symptoms). 3D volumes were obtained from surgically removed masses that had undergone histological diagnosis or from masses that had been followed up until resolution. After assessment of each set, the trainee's diagnostic performance was calculated (sensitivity and specificity) and each incorrectly classified mass was evaluated with the trainer. The objective was to achieve a sensitivity of > 95% and a specificity of > 90%. Learning curve cumulative summation (LC-CUSUM) graphs were plotted to assess the learning curve for the trainees. One trainer and two trainees with little experience in gynecological ultrasound (one gynecologist and one radiologist) participated in this study. LC-CUSUM graphs showed that competence was achieved after 170 or 185 examinations. The objectives for diagnostic performance were achieved after assessment of the second set of 3D volumes (200 cases) for each trainee. The proposed training program appears to be feasible. High diagnostic performance can be achieved after analysis of 200 cases and maintained thereafter. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 27 2011-07-01 2011-07-01 false Waste specific prohibitions-Soils... Prohibitions on Land Disposal § 268.32 Waste specific prohibitions—Soils exhibiting the toxicity characteristic... from land disposal: any volumes of soil exhibiting the toxicity characteristic solely because of the...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 28 2013-07-01 2013-07-01 false Waste specific prohibitions-Soils... Prohibitions on Land Disposal § 268.32 Waste specific prohibitions—Soils exhibiting the toxicity characteristic... from land disposal: any volumes of soil exhibiting the toxicity characteristic solely because of the...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 28 2012-07-01 2012-07-01 false Waste specific prohibitions-Soils... Prohibitions on Land Disposal § 268.32 Waste specific prohibitions—Soils exhibiting the toxicity characteristic... from land disposal: any volumes of soil exhibiting the toxicity characteristic solely because of the...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Waste specific prohibitions-Soils... Prohibitions on Land Disposal § 268.32 Waste specific prohibitions—Soils exhibiting the toxicity characteristic... from land disposal: any volumes of soil exhibiting the toxicity characteristic solely because of the...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 27 2014-07-01 2014-07-01 false Waste specific prohibitions-Soils... Prohibitions on Land Disposal § 268.32 Waste specific prohibitions—Soils exhibiting the toxicity characteristic... from land disposal: any volumes of soil exhibiting the toxicity characteristic solely because of the...
Pelham, Brett W; Shimizu, Mitsuru; Arndt, Jamie; Carvallo, Mauricio; Solomon, Sheldon; Greenberg, Jeff
2018-03-01
We tested predictions about religiosity and terror management processes in 16 nations. Specifically, we examined weekly variation in Google search volume in each nation for 12 years (all weeks for which data were available). In all 16 nations, higher than usual weekly Google search volume for life-threatening illnesses (cancer, diabetes, and hypertension) predicted increases in search volume for religious content (e.g., God, Jesus, prayer) in the following week. This effect held up after controlling for (a) recent past and annual variation in religious search volume, (b) increases in search volume associated with religious holidays, and (c) variation in searches for a non-life-threatening illness ("sore throat"). Terror management threat reduction processes appear to occur across the globe. Furthermore, they may occur over much longer periods than those studied in the laboratory. Managing fears of death via religious belief regulation appears to be culturally pervasive.
Treble-Barna, Amery; Juranek, Jenifer; Stuebing, Karla K.; Cirino, Paul T.; Dennis, Maureen; Fletcher, Jack M.
2014-01-01
The present study examined prospective and episodic memory in relation to age, functional independence, and hippocampal volume in younger to middle-aged adults with spina bifida myelomeningocele (SBM) and typically developing (TD) adults. Prospective and episodic memory, as well as hippocampal volume, were reduced in adults with SBM relative to TD adults. Neither memory performance nor hippocampal volume showed greater decrements in older adults. Lower hippocampal volume was associated with reduced prospective memory in adults with SBM, and this relation was specific to the hippocampus and not to a contrast structure, the amygdala. Prospective memory mediated the relation between hippocampal volume and functional independence in adults with SBM. The results add to emerging evidence for reduced memory function in adults with SBM, and provide quantitative evidence for compromised hippocampal macrostructure as a neural correlate of reduced memory in this population. PMID:25068670
Wetzel, Hermann
2006-01-01
In a large number of mostly retrospective association studies, a statistical relationship between volume and quality of health care has been reported. However, the relevance of these results is frequently limited by methodological shortcomings. In this article, criteria for the evidence and definition of thresholds for volume-outcome relations are proposed, e.g. the specification of relevant outcomes for quality indicators, analysis of volume as a continuous variable with an adequate case-mix and risk adjustment, accounting for cluster effects and considering mathematical models for the derivation of cut-off values. Moreover, volume thresholds are regarded as surrogate parameters for the indirect classification of the quality of care, whose diagnostic validity and effectiveness in improving health care quality need to be evaluated in prospective studies.
Salokangas, R K R; Cannon, T; Van Erp, T; Ilonen, T; Taiminen, T; Karlsson, H; Lauerma, H; Leinonen, K M; Wallenius, E; Kaljonen, A; Syvälahti, E; Vilkman, H; Alanen, A; Hietala, J
2002-09-01
Structural brain abnormalities are prevalent in patients with schizophrenia and affective disorders. To study how regional brain volumes and their ratios differ between patients with schizophrenia, psychotic depression, severe non-psychotic depression and healthy controls. Magnetic resonance imaging scans of the brain on first-episode patients and on healthy controls. Patients with schizophrenia had a smaller left frontal grey matter volume than the other three groups. Patients with psychotic depression had larger ventricular and posterior sulcal cerebrospinal fluid (CSF) volumes than controls. Patients with depression had larger white matter volumes than the other patients. Left frontal lobe, especially its grey matter volume, seems to be specifically reduced in first-episode schizophrenia. Enlarged cerebral ventricles and sulcal CSF volumes are prevalent in psychotic depression. Preserved or expanded white matter is typical of non-psychotic depression.
Paratransit Vehicle Test and Evaluation : Volume 1. Ride Comfort and Quality Tests.
DOT National Transportation Integrated Search
1978-06-01
The vehicles presently available for paratransit service do not cover the full spectrum of required characteristics necessary for public transportation. Therefore, specifications were developed by the U.S. Government for a vehicle specifically for us...
OPS MCC level B/C formulation requirements: Area targets and space volumes processor
NASA Technical Reports Server (NTRS)
Bishop, M. J., Jr.
1979-01-01
The level B/C mathematical specifications for the area targets and space volumes processor (ATSVP) are described. The processor is designed to compute the acquisition-of-signal (AOS) and loss-of-signal (LOS) times for area targets and space volumes. The characteristics of the area targets and space volumes are given. The mathematical equations necessary to determine whether the spacecraft lies within the area target or space volume are given. These equations provide a detailed model of the target geometry. A semianalytical technique for predicting the AOS and LOS time periods is disucssed. This technique was designed to bound the actual visibility period using a simplified target geometry model and unperturbed orbital motion. Functional overview of the ATSVP is presented and it's detailed logic flow is described.
Causes and consequences of reduced blood volume in space flight - A multi-discipline modeling study
NASA Technical Reports Server (NTRS)
Leonard, J. I.
1983-01-01
A group of mathematical models of various physiological systems have been developed and applied to studying problems associated with adaptation to weightlessness. One biomedical issue which could be addressed by at least three of these models from varying perspectives was the reduction in blood volume that universally occurs in astronauts. Accordingly, models of fluid-electrolyte, erythropoiesis, and cardiovascular regulation were employed to study the causes and consequences of blood volume loss during space flight. This analysis confirms the notion that alterations of blood volume are central to an understanding of adaptation to prolonged space flight. More importantly, the modeling studies resulted in specific hypotheses accounting for plasma volume and red cell mass losses and testable predictions concerning the behavior of the circulatory system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1989-01-01
This volume is one in a series of manuals prepared for EPA to assist its Remedial Project Managers in the assessment of the air contaminant pathway and developing input data for risk assessment. The manual provides guidance on developing baseline-emission estimates from hazardous waste sites. Baseline-emission estimates (BEEs) are defined as emission rates estimated for a site in its undisturbed state. Specifically, the manual is intended to: Present a protocol for selecting the appropriate level of effort to characterize baseline air emissions; Assist site managers in designing an approach for BEEs; Describe useful technologies for developing site-specific baseline emission estimatesmore » (BEEs); Help site managers select the appropriate technologies for generating site-specific BEEs.« less
Carbone, V; Fluit, R; Pellikaan, P; van der Krogt, M M; Janssen, D; Damsgaard, M; Vigneron, L; Feilkas, T; Koopman, H F J M; Verdonschot, N
2015-03-18
When analyzing complex biomechanical problems such as predicting the effects of orthopedic surgery, subject-specific musculoskeletal models are essential to achieve reliable predictions. The aim of this paper is to present the Twente Lower Extremity Model 2.0, a new comprehensive dataset of the musculoskeletal geometry of the lower extremity, which is based on medical imaging data and dissection performed on the right lower extremity of a fresh male cadaver. Bone, muscle and subcutaneous fat (including skin) volumes were segmented from computed tomography and magnetic resonance images scans. Inertial parameters were estimated from the image-based segmented volumes. A complete cadaver dissection was performed, in which bony landmarks, attachments sites and lines-of-action of 55 muscle actuators and 12 ligaments, bony wrapping surfaces, and joint geometry were measured. The obtained musculoskeletal geometry dataset was finally implemented in the AnyBody Modeling System (AnyBody Technology A/S, Aalborg, Denmark), resulting in a model consisting of 12 segments, 11 joints and 21 degrees of freedom, and including 166 muscle-tendon elements for each leg. The new TLEM 2.0 dataset was purposely built to be easily combined with novel image-based scaling techniques, such as bone surface morphing, muscle volume registration and muscle-tendon path identification, in order to obtain subject-specific musculoskeletal models in a quick and accurate way. The complete dataset, including CT and MRI scans and segmented volume and surfaces, is made available at http://www.utwente.nl/ctw/bw/research/projects/TLEMsafe for the biomechanical community, in order to accelerate the development and adoption of subject-specific models on large scale. TLEM 2.0 is freely shared for non-commercial use only, under acceptance of the TLEMsafe Research License Agreement. Copyright © 2014 Elsevier Ltd. All rights reserved.
Ates, Selma; Oksuz, Hafıze; Dogu, Bırsen; Bozkus, Fulsen; Ucmak, Hasan; Yanıt, Fadime
2015-01-01
Objectives: To determine whether the mean platelet volume (MPV) and MPV/platelet (PLT) values can be used in the study of sepsis and systemic inflammatory response syndrome (SIRS). Methods: In this retrospective case-controlled study, 69 sepsis, 69 SIRS patients, and 72 control group who were treated in the years 2012-2013 were reviewed, and both the MPV and MPV/PLT rates were evaluated in all groups at Kahramanmaras Sutcu Imam University Intensive Care Unit, Kahramanmaras, Turkey. Results: Statistically significant difference was found between sepsis, SIRS, and control groups when comparing the MPV and MPV/PLT ratio (p<0.05), and no significant difference was found between sepsis and SIRS groups in terms of MPV and MPV/PLT ratio (p>0.05). Mean platelet volume values for sepsis and control groups was 10.07/8.731 femtoliter (fL) (p=0.000), and 9.45/8.731 fL (p=0.000) for SIRS and control groups. In the group of sepsis patients, the MPV was found to be at cut-off 8.915, sensitivity 71%, and specificity 63.9%. In the group of patients with SIRS, MPV was found to be at cut-off 8.85, sensitivity 69.6%, and specificity 62.5%. For the MPV/PLT values, the specificity and sensitivity were found to be insignificant. Conclusion: This study shows that although there was no significant reduction in the PLT values between the sepsis and SIRS patients, the MPV and MPV/PLT ratio values were found to have significant differences. However, the specificity and sensitivity of the values were not reliable standard to be used as a test. PMID:26446329
Sensitive, microliter PCR with consensus degenerate primers for Epstein Barr virus amplification
Oh, Kyudam; Pak, Nikita; Saunders, D. Curtis; Conrardy, Christina; Landers, James P.; Tong, Suxiang; Forest, Craig R.
2016-01-01
Sensitive identification of the etiology of viral diseases is key to implementing appropriate prevention and treatment. The gold standard for virus identification is the polymerase chain reaction (PCR), a technique that allows for highly specific and sensitive detection of pathogens by exponentially amplifying a specific region of DNA from as little as a single copy through thermocycling a biochemical cocktail. Today, molecular biology laboratories use commercial instruments that operate in 0.5–2 h/analysis using reaction volumes of 5–50 μL contained within polymer tubes or chambers. Towards reducing this volume and maintaining performance, we present a semi-quantitative, systematic experimental study of how PCR yield is affected by tube/chamber substrate, surface-area-to-volume ratio (SA:V), and passivation methods. We perform PCR experiments using traditional PCR tubes as well as using disposable polymer microchips with 1 μL reaction volumes thermocycled using water baths. We report the first oil encapsulation microfluidic PCR method without fluid flow and its application to the first microfluidic amplification of Epstein Barr virus using consensus degenerate primers, a powerful and broad PCR method to screen for both known and novel members of a viral family. The limit of detection is measured as 140 starting copies of DNA from a starting concentration of 3×105 copies/mL, regarded as an accepted sensitivity threshold for diagnostic purposes, and reaction specificity was improved as compared to conventional methods. Also notable, these experiments were conducted with conventional reagent concentrations, rather than commonly spiked enzyme and/or template mixtures. This experimental study of the effects of substrate, SA:V, and passivation, together with sensitive and specific microfluidic PCR with consensus degenerate primers represent advances towards lower cost and higher throughput pathogen screening. PMID:23080522
England, Heather B.; Gillis, M. Meredith; Hampstead, Benjamin M.
2014-01-01
The current study (i) determined whether NeuroQuant® volumetrics are reflective of differences in medial temporal lobe (MTL) volumes between healthy older adults and those with mild cognitive impairment (MCI) and (ii) examined the relationship between RBANS indices and MTL volumes. Forty-three healthy older adults and 57 MCI patients completed the RBANS and underwent structural MRI. Hippocampal and inferior lateral ventricle (ILV) volumes were obtained using NeuroQuant®. Results revealed significantly smaller hippocampal and larger ILV volumes in MCI patients. MTL volumes were significantly related to the RBANS Immediate and Delayed Memory and Language indices but not the Attention or Visuoconstruction indices; findings that demonstrate anatomical specificity. Following discriminant function analysis, we calculated a cutpoint that may prove clinically useful for integrating MTL volumes into the diagnosis of MCI. These findings demonstrate the potential clinical utility of NeuroQuant® and are the first to document the relationship between RBANS indices and MTL volumes. PMID:24709384
Lawson, Gwendolyn M.; Camins, Joshua S.; Wisse, Laura; Wu, Jue; Duda, Jeffrey T.; Cook, Philip A.; Gee, James C.; Farah, Martha J.
2017-01-01
The present study examined the relationship between childhood socioeconomic status (SES), childhood maltreatment, and the volumes of the hippocampus and amygdala between the ages of 25 and 36 years. Previous work has linked both low SES and maltreatment with reduced hippocampal volume in childhood, an effect attributed to childhood stress. In 46 adult subjects, only childhood maltreatment, and not childhood SES, predicted hippocampal volume in regression analyses, with greater maltreatment associated with lower volume. Neither factor was related to amygdala volume. When current SES and recent interpersonal stressful events were also considered, recent interpersonal stressful events predicted smaller hippocampal volumes over and above childhood maltreatment. Finally, exploratory analyses revealed a significant sex by childhood SES interaction, with women’s childhood SES showing a significantly more positive relation (less negative) with hippocampus volume than men’s. The overall effect of childhood maltreatment but not SES, and the sex-specific effect of childhood SES, indicate that different forms of stressful childhood adversity affect brain development differently. PMID:28414755
Patient-specific coronary artery blood flow simulation using myocardial volume partitioning
NASA Astrophysics Data System (ADS)
Kim, Kyung Hwan; Kang, Dongwoo; Kang, Nahyup; Kim, Ji-Yeon; Lee, Hyong-Euk; Kim, James D. K.
2013-03-01
Using computational simulation, we can analyze cardiovascular disease in non-invasive and quantitative manners. More specifically, computational modeling and simulation technology has enabled us to analyze functional aspect such as blood flow, as well as anatomical aspect such as stenosis, from medical images without invasive measurements. Note that the simplest ways to perform blood flow simulation is to apply patient-specific coronary anatomy with other average-valued properties; in this case, however, such conditions cannot fully reflect accurate physiological properties of patients. To resolve this limitation, we present a new patient-specific coronary blood flow simulation method by myocardial volume partitioning considering artery/myocardium structural correspondence. We focus on that blood supply is closely related to the mass of each myocardial segment corresponding to the artery. Therefore, we applied this concept for setting-up simulation conditions in the way to consider many patient-specific features as possible from medical image: First, we segmented coronary arteries and myocardium separately from cardiac CT; then the myocardium is partitioned into multiple regions based on coronary vasculature. The myocardial mass and required blood mass for each artery are estimated by converting myocardial volume fraction. Finally, the required blood mass is used as boundary conditions for each artery outlet, with given average aortic blood flow rate and pressure. To show effectiveness of the proposed method, fractional flow reserve (FFR) by simulation using CT image has been compared with invasive FFR measurement of real patient data, and as a result, 77% of accuracy has been obtained.
Bondarenko, Semen M.; Artemov, Gleb N.; Stegniy, Vladimir N.
2017-01-01
Spatial organization of chromosome territories is important for maintenance of genomic stability and regulation of gene expression. Recent studies have shown tissue-specific features of chromosome attachments to the nuclear envelope in various organisms including malaria mosquitoes. However, other spatial characteristics of nucleus organization, like volume and shape of chromosome territories, have not been studied in Anopheles. We conducted a thorough analysis of tissue-specific features of the X chromosome and nucleolus volume and shape in follicular epithelium and nurse cells of the Anopheles atroparvus ovaries using a modern open-source software. DNA of the polytene X chromosome from ovarian nurse cells was obtained by microdissection and was used as a template for amplification with degenerate oligo primers. A fluorescently labeled X chromosome painting probe was hybridized with formaldehyde-fixed ovaries of mosquitoes using a 3D-FISH method. The nucleolus was stained by immunostaining with an anti-fibrillarin antibody. The analysis was conducted with TANGO—a software for a chromosome spatial organization analysis. We show that the volume and position of the X chromosome have tissue-specific characteristics. Unlike nurse cell nuclei, the growth of follicular epithelium nuclei is not accompanied with the proportional growth of the X chromosome. However, the shape of the X chromosome does not differ between the tissues. The dynamics of the X chromosome attachment regions location is tissue-specific and it is correlated with the process of nucleus growth in follicular epithelium and nurse cells. PMID:28158219
Bondarenko, Semen M; Artemov, Gleb N; Sharakhov, Igor V; Stegniy, Vladimir N
2017-01-01
Spatial organization of chromosome territories is important for maintenance of genomic stability and regulation of gene expression. Recent studies have shown tissue-specific features of chromosome attachments to the nuclear envelope in various organisms including malaria mosquitoes. However, other spatial characteristics of nucleus organization, like volume and shape of chromosome territories, have not been studied in Anopheles. We conducted a thorough analysis of tissue-specific features of the X chromosome and nucleolus volume and shape in follicular epithelium and nurse cells of the Anopheles atroparvus ovaries using a modern open-source software. DNA of the polytene X chromosome from ovarian nurse cells was obtained by microdissection and was used as a template for amplification with degenerate oligo primers. A fluorescently labeled X chromosome painting probe was hybridized with formaldehyde-fixed ovaries of mosquitoes using a 3D-FISH method. The nucleolus was stained by immunostaining with an anti-fibrillarin antibody. The analysis was conducted with TANGO-a software for a chromosome spatial organization analysis. We show that the volume and position of the X chromosome have tissue-specific characteristics. Unlike nurse cell nuclei, the growth of follicular epithelium nuclei is not accompanied with the proportional growth of the X chromosome. However, the shape of the X chromosome does not differ between the tissues. The dynamics of the X chromosome attachment regions location is tissue-specific and it is correlated with the process of nucleus growth in follicular epithelium and nurse cells.
NCRVE Change Agent. Shaping the Future of Vocational Education. Volume 4, 1994.
ERIC Educational Resources Information Center
NCRVE Change Agent, 1994
1994-01-01
The first of four issues in this volume consists of four review articles. "Tech Prep Quality" reviews a guide to total quality management and tech prep. "Specific, Ocean to Ocean" reviews a publication that identifies 10 preliminary plans for implementing tech prep. "...No Single Option" is about a monograph that evaluates tech prep and other…
The Danger-to-Self-or-Others Exception to Confidentiality. ACA Legal Series, Volume 8.
ERIC Educational Resources Information Center
Ahia, C. Emmanuel; Martin, Dan
A counselor's obligation to safeguard information shared in counseling has clinical, ethical, and legal implications. This volume focuses on the duty-to-warn exception in client confidentiality. It provides general ethical and legal guidelines and, where possible, specific information to help the practitioner make good choices. It is intended for…
Stumpage prices and volumes sold for individual western national forests: 1984-2007.
David Kling
2008-01-01
Sold prices for national forest stumpage provide geographically specific price references for timber. This report presents sold price series for western national forests from 1984 through first 3 months of 2007. Selected trends in stumpage prices and sold volumes as well as issues related to species aggregation in the data are also discussed.
The Value of Children: A Cross-National Study, Volume Three. Hawaii.
ERIC Educational Resources Information Center
Arnold, Fred; Fawcett, James T.
The document, one in a series of seven reports from the Value of Children Project, discusses results of the survey in Hawaii. Specifically, the study investigated the social, psychological, and economic costs and benefits associated with having children. The volume is presented in seven chapters. Chapter I describes the background of the study and…
ERIC Educational Resources Information Center
Naik, Chitra; And Others
The volume contains two studies from India and Thailand on the education of women, and rural women especially, who are deprived or disadvantaged. The Indian study, "Education of Girls and Women in Deprived Groups," presents a viewpoint on deprivation in society in general, and India specifically. The concomitant of deprivation is defined…
ERIC Educational Resources Information Center
Rossi, Robert J.; Stringfield, Samuel C.
Despite the widespread attention given to education reform, no substantial knowledge base has existed for identifying and implementing specific effective reforms. This document, the first of three volumes, presents findings of a study that sought to identify the essential mechanics of effective reforms for students at risk. The study also…
Advances in planetary geology, volume 2
NASA Technical Reports Server (NTRS)
1986-01-01
This publication is a continuation of volume 1; it is a compilation of reports focusing on research into the origin and evolution of the solar system with emphasis on planetary geology. Specific reports include a multispectral and geomorphic investigation of the surface of Europa and a geologic interpretation of remote sensing data for the Martian volcano Ascreaus Mons.
ERIC Educational Resources Information Center
Anfara, Vincent A., Jr., Ed.; Stacki, Sandra L., Ed.
This volume theorizes, describes, and explains practices and some specific programs designed to help meet the needs and demands of a diverse student population. The central point of this volume is that curriculum, instruction, and assessment in middle-level education is a dynamic, interrelated system undergoing change. The book contains the…
Computation Techniques for the Volume of a Tetrahedron
ERIC Educational Resources Information Center
Srinivasan, V. K.
2010-01-01
The purpose of this article is to discuss specific techniques for the computation of the volume of a tetrahedron. A few of them are taught in the undergraduate multivariable calculus courses. Few of them are found in text books on coordinate geometry and synthetic solid geometry. This article gathers many of these techniques so as to constitute a…
Marxist Influences and South Asian Literature. South Asia Series Occasional Paper No. 23, Vol. II.
ERIC Educational Resources Information Center
Coppola, Carlo, Ed.
This document is the second of two volumes of papers dealing with various aspects of Marxist literary influence, and more specifically socialist realism, in India, Pakistan, and Bangladesh. Included in this volume are articles that deal with such subjects as socialist realism and the progressive movement in Malayalam, realism in Marathi creative…
Gavra, Paul; Nguyen, Anne Q-N; Theoret, Yves; Litalien, Catherine; Denault, André Y; Varin, France
2014-10-01
Milrinone administered through inhalation is an emerging method aimed at specifically reducing pulmonary hypertension without affecting systemic pressures. Its administration has been shown to be useful both in patients undergoing cardiac surgery and for persistent pulmonary hypertension of the newborn. These populations are prone to receive many concomitant medications and/or blood sampling may require a low volume quantification method. To address these issues in view of pharmacokinetic studies, this article aims to develop and validate a specific and sensitive analytical assay using high performance liquid chromatography (HPLC) and tandem mass spectrometry (MS/MS) detection for the quantification of milrinone plasma concentrations after inhalation in patients undergoing cardiac surgery. Plasma samples (50 μL) were extracted using ethyl acetate. Milrinone was separated on a C18 analytical column at 50°C. The mobile phase consisted of methanol and 10 mM ammonium acetate (45:55 vol/vol). The electrospray was operated in the negative ionization mode and monitored the following mass transitions: m/z 212.1 → 140.0 at 36 eV for milrinone and m/z 252.1 → 156.1 at 32 eV for olprinone. Calibration curves followed a quadratic regression in the concentration range of 0.3125-640 ng/mL. The lower limit of quantification is 0.3125 ng/mL and is based on a low plasma volume of 50 μL. Mean drug recovery and accuracy were ≥72.3% and 96.0%, respectively. Intraday and interday precision coefficient of variation (%) was ≤7.4% and ≤11.5%, respectively. The specificity allowed milrinone quantification in the multidrug administration conditions of cardiopulmonary bypass. This validated micromethod proved to be highly sensitive and specific while using a low volume of plasma. Its low volume and its lower limit of quantification indicate that this approach is suitable for further characterization of milrinone pharmacokinetics in both adults (inhalation) and neonates.
Staircase polymetalsilicon nanocomplexes - Polymetalphenyl siloxanes: Structure and properties
NASA Astrophysics Data System (ADS)
Shapkin, N. P.; Balanov, M. I.; Razov, V. I.; Gardionov, S. V.; Mayorov, V. Yu; Tokar, E. A.; Papynov, E. K.; Korochentsev, V. V.; Leont'ev, L. B.; Slobodyuk, A. B.; Modin, E. B.
2018-03-01
Polyphenyl siloxanes containing chromium, iron, and aluminum in the backbone chain have been synthesized. The structure of the obtained staircase nano-metal complexes has been studied by the methods of XRD analysis and IR, 29Si and 27Al NMR, and XPS spectroscopy and scanning electron microscopy. Physical-chemical characteristics of these compounds have been investigated by the positron annihilation spectroscopy (PAS) and low-temperature nitrogen adsorption. The data of X-ray diffraction analysis (XRD) enabled us to calculate the size and volume of coherent scattering regions (CSR) and the cross-section area of the polymer chains. By means of the PAS method, the specific volumes of positron (Ve+) and positronium (Vps) "traps" have been calculated. The data of 29Si NMR spectroscopy have shown the presence of T2 and T3 fragments in the structure. As was shown on the basis of the data of 27Al NMR and XPS spectroscopy, tetrahedral (66%) and octahedral surroundings of the metal atom were realized in the backbone chain. The obtained data were used to describe a spatial layered structure of phenyl siloxanes containing trivalent metals. The electron microscopy of nanocomplexes revealed the presence of spherical particles, whose size changes in cases of chromium, iron, and aluminum. Using the data of low-temperature nitrogen adsorption, it was assumed that the specific surface area was filled with a layer of compacted spherical particles, whereas the layer thickness was determined, in its turn, by the specific polarizing potential (SPP) calculated as a ratio of the polarizing potential (PP) to the volume of voids between coherent scattering regions. Similar dependence is observed between the layer thickness and the specific polarizing potential calculated as a ratio of the polarizing potential to the positronium "trap" volume. A direct dependence between the thickness of the spherical particles layer and the specific polarizing potential has been demonstrated. The assumption on a fractal structure of spherical particles was made. Tribotechnical properties of the motor oil with metal siloxane additives have been studied.
Polte, Christian L; Gao, Sinsia A; Johnsson, Åse A; Lagerstrand, Kerstin M; Bech-Hanssen, Odd
2017-06-15
Grading of chronic aortic regurgitation (AR) and mitral regurgitation (MR) by cardiovascular magnetic resonance (CMR) is currently based on thresholds, which are neither modality nor quantification method specific. Accordingly, this study sought to identify CMR-specific and quantification method-specific thresholds for regurgitant volumes (RVols), RVol indexes, and regurgitant fractions (RFs), which denote severe chronic AR or MR with an indication for surgery. The study comprised patients with moderate and severe chronic AR (n = 38) and MR (n = 40). Echocardiography and CMR was performed at baseline and in all operated AR/MR patients (n = 23/25) 10 ± 1 months after surgery. CMR quantification of AR: direct (aortic flow) and indirect method (left ventricular stroke volume [LVSV] - pulmonary stroke volume [PuSV]); MR: 2 indirect methods (LVSV - aortic forward flow [AoFF]; mitral inflow [MiIF] - AoFF). All operated patients had severe regurgitation and benefited from surgery, indicated by a significant postsurgical reduction in end-diastolic volume index and improvement or relief of symptoms. The discriminatory ability between moderate and severe AR was strong for RVol >40 ml, RVol index >20 ml/m 2 , and RF >30% (direct method) and RVol >62 ml, RVol index >31 ml/m 2 , and RF >36% (LVSV-PuSV) with a negative likelihood ratio ≤ 0.2. In MR, the discriminatory ability was very strong for RVol >64 ml, RVol index >32 ml/m 2 , and RF >41% (LVSV-AoFF) and RVol >40 ml, RVol index >20 ml/m 2 , and RF >30% (MiIF-AoFF) with a negative likelihood ratio < 0.1. In conclusion, CMR grading of chronic AR and MR should be based on modality-specific and quantification method-specific thresholds, as they differ largely from recognized guideline criteria, to assure appropriate clinical decision-making and timing of surgery. Copyright © 2017 Elsevier Inc. All rights reserved.
Volume change associated with formation and dissociation of hydrate in sediment
Ruppel, Carolyn D.; Lee, J.Y.; Santamarina, J. Carlos
2017-01-01
Gas hydrate formation and dissociation in sediments are accompanied by changes in the bulk volume of the sediment and can lead to changes in sediment properties, loss of integrity for boreholes, and possibly regional subsidence of the ground surface over areas where methane might be produced from gas hydrate in the future. Experiments on sand, silts, and clay subject to different effective stress and containing different saturations of hydrate formed from dissolved phase tetrahydrofuran are used to systematically investigate the impact of gas hydrate formation and dissociation on bulk sediment volume. Volume changes in low specific surface sediments (i.e., having a rigid sediment skeleton like sand) are much lower than those measured in high specific surface sediments (e.g., clay). Early hydrate formation is accompanied by contraction for all soils and most stress states in part because growing gas hydrate crystals buckle skeletal force chains. Dilation can occur at high hydrate saturations. Hydrate dissociation under drained, zero lateral strain conditions is always associated with some contraction, regardless of soil type, effective stress level, or hydrate saturation. Changes in void ratio during formation-dissociation decrease at high effective stress levels. The volumetric strain during dissociation under zero lateral strain scales with hydrate saturation and sediment compressibility. The volumetric strain during dissociation under high shear is a function of the initial volume average void ratio and the stress-dependent critical state void ratio of the sediment. Other contributions to volume reduction upon hydrate dissociation are related to segregated hydrate in lenses and nodules. For natural gas hydrates, some conditions (e.g., gas production driven by depressurization) might contribute to additional volume reduction by increasing the effective stress.
2012-01-01
Background In this paper a new non-invasive, operator-free, continuous ventricular stroke volume monitoring device (Hemodynamic Cardiac Profiler, HCP) is presented, that measures the average stroke volume (SV) for each period of 20 seconds, as well as ventricular volume-time curves for each cardiac cycle, using a new electric method (Ventricular Field Recognition) with six independent electrode pairs distributed over the frontal thoracic skin. In contrast to existing non-invasive electric methods, our method does not use the algorithms of impedance or bioreactance cardiography. Instead, our method is based on specific 2D spatial patterns on the thoracic skin, representing the distribution, over the thorax, of changes in the applied current field caused by cardiac volume changes during the cardiac cycle. Since total heart volume variation during the cardiac cycle is a poor indicator for ventricular stroke volume, our HCP separates atrial filling effects from ventricular filling effects, and retrieves the volume changes of only the ventricles. Methods ex-vivo experiments on a post-mortem human heart have been performed to measure the effects of increasing the blood volume inside the ventricles in isolation, leaving the atrial volume invariant (which can not be done in-vivo). These effects have been measured as a specific 2D pattern of voltage changes on the thoracic skin. Furthermore, a working prototype of the HCP has been developed that uses these ex-vivo results in an algorithm to decompose voltage changes, that were measured in-vivo by the HCP on the thoracic skin of a human volunteer, into an atrial component and a ventricular component, in almost real-time (with a delay of maximally 39 seconds). The HCP prototype has been tested in-vivo on 7 human volunteers, using G-suit inflation and deflation to provoke stroke volume changes, and LVot Doppler as a reference technique. Results The ex-vivo measurements showed that ventricular filling caused a pattern over the thorax quite distinct from that of atrial filling. The in-vivo tests of the HCP with LVot Doppler resulted in a Pearson’s correlation of R = 0.892, and Bland-Altman plotting of SV yielded a mean bias of -1.6 ml and 2SD =14.8 ml. Conclusions The results indicate that the HCP was able to track the changes in ventricular stroke volume reliably. Furthermore, the HCP produced ventricular volume-time curves that were consistent with the literature, and may be a diagnostic tool as well. PMID:22900831
Nakamura, S; Suzuki, K; Ohtsubo, K
2009-04-01
Characteristics of the bread prepared from wheat flour blended with the flour of various kinds of newly developed rice cultivars were investigated. Qualities of the bread made from wheat flour blended with rice flour have been reported to be inferior to those from 100% wheat flour bread. To improve its qualities, we searched for the new-characteristic rice flours among the various kinds of newly developed rice cultivars to blend with the wheat flour for the bread preparation. The most suitable new characteristic rices are combination of purple waxy rice, high-amylose rice, and sugary rice. Specific volume of the bread from the combination of wheat and these 3 kinds of rice flours showed higher specific volume (3.93) compared with the traditional wheat/rice bread (3.58). We adopted the novel method, continuous progressive compression test, to measure the physical properties of the dough and the bread in addition to the sensory evaluation. As a result of the selection of the most suitable rice cultivars and blending ratio with the wheat flour, we could develop the novel wheat/rice bread, of which loaf volume, physical properties, and tastes are acceptable and resistant to firming on even 4 d after the bread preparation. To increase the ratio of rice to wheat, we tried to add a part of rice as cooked rice grains. The specific volume and qualities of the bread were maintained well although the rice content of total flour increased from 30% to 40%.
NASA Astrophysics Data System (ADS)
Gloger, Oliver; Tönnies, Klaus; Mensel, Birger; Völzke, Henry
2015-11-01
In epidemiological studies as well as in clinical practice the amount of produced medical image data strongly increased in the last decade. In this context organ segmentation in MR volume data gained increasing attention for medical applications. Especially in large-scale population-based studies organ volumetry is highly relevant requiring exact organ segmentation. Since manual segmentation is time-consuming and prone to reader variability, large-scale studies need automatized methods to perform organ segmentation. Fully automatic organ segmentation in native MR image data has proven to be a very challenging task. Imaging artifacts as well as inter- and intrasubject MR-intensity differences complicate the application of supervised learning strategies. Thus, we propose a modularized framework of a two-stepped probabilistic approach that generates subject-specific probability maps for renal parenchyma tissue, which are refined subsequently by using several, extended segmentation strategies. We present a three class-based support vector machine recognition system that incorporates Fourier descriptors as shape features to recognize and segment characteristic parenchyma parts. Probabilistic methods use the segmented characteristic parenchyma parts to generate high quality subject-specific parenchyma probability maps. Several refinement strategies including a final shape-based 3D level set segmentation technique are used in subsequent processing modules to segment renal parenchyma. Furthermore, our framework recognizes and excludes renal cysts from parenchymal volume, which is important to analyze renal functions. Volume errors and Dice coefficients show that our presented framework outperforms existing approaches.
The Volumetric Diversity of Misfolded Prion Protein Oligomers Revealed by Pressure Dissociation*
Torrent, Joan; Lange, Reinhard; Rezaei, Human
2015-01-01
Protein oligomerization has been associated with a wide range of diseases. High pressure approaches offer a powerful tool for deciphering the underlying molecular mechanisms by revealing volume changes associated with the misfolding and assembly reactions. We applied high pressure to induce conformational changes in three distinct β-sheet-rich oligomers of the prion protein PrP, a protein characterized by a variety of infectious quaternary structures that can propagate stably and faithfully and cause diseases with specific phenotypic traits. We show that pressure induces dissociation of the oligomers and leads to a lower volume monomeric PrP state that refolds into the native conformation after pressure release. By measuring the different pressure and temperature sensitivity of the tested PrP oligomers, we demonstrate significantly different void volumes in their quaternary structure. In addition, by focusing on the kinetic and energetic behavior of the pressure-induced dissociation of one specific PrP oligomer, we reveal a large negative activation volume and an increase in both apparent activation enthalpy and entropy. This suggests a transition state ensemble that is less structured and significantly more hydrated than the oligomeric state. Finally, we found that site-specific fluorescent labeling allows monitoring of the transient population of a kinetic intermediate in the dissociation reaction. Our results indicate that defects in atomic packing may deserve consideration as a new factor that influences differences between PrP assemblies and that could be relevant also for explaining the origin of prion strains. PMID:26126829
Gloger, Oliver; Tönnies, Klaus; Mensel, Birger; Völzke, Henry
2015-11-21
In epidemiological studies as well as in clinical practice the amount of produced medical image data strongly increased in the last decade. In this context organ segmentation in MR volume data gained increasing attention for medical applications. Especially in large-scale population-based studies organ volumetry is highly relevant requiring exact organ segmentation. Since manual segmentation is time-consuming and prone to reader variability, large-scale studies need automatized methods to perform organ segmentation. Fully automatic organ segmentation in native MR image data has proven to be a very challenging task. Imaging artifacts as well as inter- and intrasubject MR-intensity differences complicate the application of supervised learning strategies. Thus, we propose a modularized framework of a two-stepped probabilistic approach that generates subject-specific probability maps for renal parenchyma tissue, which are refined subsequently by using several, extended segmentation strategies. We present a three class-based support vector machine recognition system that incorporates Fourier descriptors as shape features to recognize and segment characteristic parenchyma parts. Probabilistic methods use the segmented characteristic parenchyma parts to generate high quality subject-specific parenchyma probability maps. Several refinement strategies including a final shape-based 3D level set segmentation technique are used in subsequent processing modules to segment renal parenchyma. Furthermore, our framework recognizes and excludes renal cysts from parenchymal volume, which is important to analyze renal functions. Volume errors and Dice coefficients show that our presented framework outperforms existing approaches.
NASA Astrophysics Data System (ADS)
Gloger, Oliver; Tönnies, Klaus; Bülow, Robin; Völzke, Henry
2017-07-01
To develop the first fully automated 3D spleen segmentation framework derived from T1-weighted magnetic resonance (MR) imaging data and to verify its performance for spleen delineation and volumetry. This approach considers the issue of low contrast between spleen and adjacent tissue in non-contrast-enhanced MR images. Native T1-weighted MR volume data was performed on a 1.5 T MR system in an epidemiological study. We analyzed random subsamples of MR examinations without pathologies to develop and verify the spleen segmentation framework. The framework is modularized to include different kinds of prior knowledge into the segmentation pipeline. Classification by support vector machines differentiates between five different shape types in computed foreground probability maps and recognizes characteristic spleen regions in axial slices of MR volume data. A spleen-shape space generated by training produces subject-specific prior shape knowledge that is then incorporated into a final 3D level set segmentation method. Individually adapted shape-driven forces as well as image-driven forces resulting from refined foreground probability maps steer the level set successfully to the segment the spleen. The framework achieves promising segmentation results with mean Dice coefficients of nearly 0.91 and low volumetric mean errors of 6.3%. The presented spleen segmentation approach can delineate spleen tissue in native MR volume data. Several kinds of prior shape knowledge including subject-specific 3D prior shape knowledge can be used to guide segmentation processes achieving promising results.
The generalization of charged AdS black hole specific volume and number density
NASA Astrophysics Data System (ADS)
Wang, Zi-Liang; He, Miao; Fang, Chao; Sun, Dao-Quan; Deng, Jian-Bo
2017-04-01
In this paper, by proposing a generalized specific volume, we restudy the P- V criticality of charged AdS black holes in the extended phase space. The results show that most of the previous conclusions can be generalized without change, but the ratio {\\tilde{ρ }}_c should be 3 {\\tilde{α }}/16 in general case. Further research on the thermodynamical phase transition of black hole leads us to a natural interpretation of our assumption, and more black hole properties can be generalized. Finally, we study the number density for charged AdS black hole in higher dimensions, the results show the necessity of our assumption.
Multiaxial behavior of foams - Experiments and modeling
NASA Astrophysics Data System (ADS)
Maheo, Laurent; Guérard, Sandra; Rio, Gérard; Donnard, Adrien; Viot, Philippe
2015-09-01
Cellular materials are strongly related to pressure level inside the material. It is therefore important to use experiments which can highlight (i) the pressure-volume behavior, (ii) the shear-shape behavior for different pressure level. Authors propose to use hydrostatic compressive, shear and combined pressure-shear tests to determine cellular materials behavior. Finite Element Modeling must take into account these behavior specificities. Authors chose to use a behavior law with a Hyperelastic, a Viscous and a Hysteretic contributions. Specific developments has been performed on the Hyperelastic one by separating the spherical and the deviatoric part to take into account volume change and shape change characteristics of cellular materials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Delnick, F.M.
1993-11-01
Carbon supercapacitors are represented as distributed RC networks with transmission line equivalent circuits. At low charge/discharge rates and low frequencies these networks approximate a simple series R{sub ESR}C circuit. The energy efficiency of the supercapacitor is limited by the voltage drop across the ESR. The pore structure of the carbon electrode defines the electrochemically active surface area which in turn establishes the volume specific capacitance of the carbon material. To date, the highest volume specific capacitance reported for a supercapacitor electrode is 220F/cm{sup 3} in aqueous H{sub 2}SO{sub 4} (10) and {approximately}60 F/cm{sup 3} in nonaqueous electrolyte (8).
Optimization of gluten-free formulations for French-style breads.
Mezaize, S; Chevallier, S; Le Bail, A; de Lamballerie, M
2009-04-01
The formulation of gluten-free bread, which will be suitable for patients with coeliac disease, was optimized to provide bread similar to French bread. The effects of the presence of hydrocolloids and the substitution of the flour basis by flour or proteins from different sources were studied. The added ingredients were (1) hydrocolloids (carboxymethylcellulose [CMC], guar gum, hydroxypropylmethylcellulose [HPMC], and xanthan gum), and (2) substitutes (buckwheat flour, whole egg powder, and whey proteins). The bread quality parameters measured were specific volume, dry matter of bread, crust color, crumb hardness, and gas cell size distribution. Specific volume was increased by guar gum and HPMC. Breads with guar gum had color characteristics similar to French bread. Hardness decreased with the addition of hydrocolloids, especially HPMC and guar. Breads with guar gum had the most heterogeneous cell size distribution, and guar gum was therefore selected for further formulations. Bread prepared with buckwheat flour had improved quality: an increased specific volume, a softer texture, color characteristics, and gas-cell size distribution similar to French bread. Bread with 1.9% guar gum (w/w, total flour basis) and 5% buckwheat flour (of all flours and substitutes) mimicked French bread quality attributes.
Halene, Tobias B.; Kozlenkov, Alexey; Jiang, Yan; Mitchell, Amanda; Javidfar, Behnam; Dincer, Aslihan; Park, Royce; Wiseman, Jennifer; Croxson, Paula; Giannaris, Eustathia Lela; Hof, Patrick R.; Roussos, Panos; Dracheva, Stella; Hemby, Scott E.; Akbarian, Schahram
2016-01-01
Increased neuronal densities in subcortical white matter have been reported for some cases with schizophrenia. The underlying cellular and molecular mechanisms remain unresolved. We exposed 26 young adult macaque monkeys for 6 months to either clozapine, haloperidol or placebo and measured by structural MRI frontal gray and white matter volumes before and after treatment, followed by observer-independent, flow-cytometry-based quantification of neuronal and non-neuronal nuclei and molecular fingerprinting of cell-type specific transcripts. After clozapine exposure, the proportion of nuclei expressing the neuronal marker NeuN increased by approximately 50% in subcortical white matter, in conjunction with a more subtle and non-significant increase in overlying gray matter. Numbers and proportions of nuclei expressing the oligodendrocyte lineage marker, OLIG2, and cell-type specific RNA expression patterns, were maintained after antipsychotic drug exposure. Frontal lobe gray and white matter volumes remained indistinguishable between antipsychotic-drug-exposed and control groups. Chronic clozapine exposure increases the proportion of NeuN+ nuclei in frontal subcortical white matter, without alterations in frontal lobe volumes or cell type-specific gene expression. Further exploration of neurochemical plasticity in non-human primate brain exposed to antipsychotic drugs is warranted. PMID:26776227
Preparation and characterization of pitch-based nanoporous carbons for improving CO{sub 2} capture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Seul-Yi; Yoo, Hye-Min; Park, Sang Wook
2014-07-01
Pitch is considered a promising low-cost carbon precursor. However, when pitch is pyrolyzed, it forms polycrystalline graphite, which is non-porous, and therefore, not useful for CO{sub 2} adsorption. In this work, pitch was chemically activated to obtain a large specific surface area and micropore volume. Varying weight ratios of KOH (i.e., 0, 1, 2, and 3) were used as the activating agent. The characteristics of the samples were investigated using scanning electron microscopy (SEM), N{sub 2}/77 K adsorption isotherms, and X-ray diffraction (XRD). The CO{sub 2} adsorption performance was studied by isothermal adsorption/desorption measurements. The results showed that an increasemore » in specific surface areas and total pore volumes of pitch-based nanoporous carbons, resulted in an enhancement of CO{sub 2} adsorption capacity. - Graphical abstract: This is the surface morphologies of pitch precursor and pitch-derived activated carbon (AC-2). - Highlights: • Pitch is considered a promising low-cost carbon precursor. • Specific surface area: 1442 m{sup 2}/g and micropore volume: 0.504 cm{sup 3}/g. • CO{sub 2} adsorption capacity showed 203 mg/g (@ RT/1 bar)« less
Sharma, P; Bhargava, M; Sukhachev, D; Datta, S; Wattal, C
2014-02-01
Tropical febrile illnesses such as malaria and dengue are challenging to differentiate clinically. Automated cellular indices from hematology analyzers may afford a preliminary rapid distinction. Blood count and VCS parameters from 114 malaria patients, 105 dengue patients, and 105 febrile controls without dengue or malaria were analyzed. Statistical discriminant functions were generated, and their diagnostic performances were assessed by ROC curve analysis. Three statistical functions were generated: (i) malaria-vs.-controls factor incorporating platelet count and standard deviations of lymphocyte volume and conductivity that identified malaria with 90.4% sensitivity, 88.6% specificity; (ii) dengue-vs.-controls factor incorporating platelet count, lymphocyte percentage and standard deviation of lymphocyte conductivity that identified dengue with 81.0% sensitivity and 77.1% specificity; and (iii) febrile-controls-vs.-malaria/dengue factor incorporating mean corpuscular hemoglobin concentration, neutrophil percentage, mean lymphocyte and monocyte volumes, and standard deviation of monocyte volume that distinguished malaria and dengue from other febrile illnesses with 85.1% sensitivity and 91.4% specificity. Leukocyte abnormalities quantitated by automated analyzers successfully identified malaria and dengue and distinguished them from other fevers. These economic discriminant functions can be rapidly calculated by analyzer software programs to generate electronic flags to trigger-specific testing. They could potentially transform diagnostic approaches to tropical febrile illnesses in cost-constrained settings. © 2013 John Wiley & Sons Ltd.
Radwaste desk reference - Volume 3, Part 2: Liquid waste management. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deltete, D.; Fisher, S.; Kelly, J.J.
1994-05-01
EPRI began, in late in 1987, to produce a Radwaste Desk Reference that would allow each of the member utilities access to the available information and expertise on radwaste management. EPRI considers this important because radwaste management involves a wide variety of scientific and engineering disciplines. These include chemical and mechanical engineering, chemistry, and health physics. Radwaste management also plays a role in implementing a wide variety of regulatory requirements. These include plant-specific technical specifications, NRC standards for protection against radiation, DOT transportation regulations and major environmental legislation such as the Resource Conservation and Recovery Act. EPRI chose a questionmore » and answer format because it could be easily accessed by radwaste professionals with a variety of interests. The questions were generated at two meetings of utility radwaste professionals and EPRI contractors. Volume 1, which is already in publication, addresses dry active waste generation, processing and measurement. Volume 2 addresses low level waste storage, transportation and disposal. This volume, Volume 3, is being issued in two parts. Part 1 concentrates on the processing of liquid radioactive waste, whereas Part 2, included here, addresses liquid waste management. It includes extensive information and operating practices related to liquid waste generation and control, liquid waste processing systems at existing U.S. nuclear plants, processes for managing wet wastes (handling, dewatering, solidifying, processing, and packaging), and liquid waste measurement and analysis.« less
Brückner, Adrian; Heethoff, Michael; Blüthgen, Nico
2017-01-01
Long-chain cuticular hydrocarbons (CHCs) are common components of the epicuticle of terrestrial arthropods. CHC serve as a protective barrier against environmental influences but also act as semiochemicals in animal communication. Regarding the latter aspect, species- or intra-functional group specific CHCs composition and variation are relatively well studied. However, comparative knowledge about the relationship of CHC quantity and their relation to surface area—volume ratios in the context of water loss and protection is fragmentary. Hence, we aim to study the taxon-specific relationship of the CHC amount and surface-area to volume ratio related to their functional role (e.g. in water loss). We focused on flower visiting insects and analyzed the CHC amounts of three insect orders (Hymenoptera, Lepidoptera and Diptera) using gas chromatography—mass spectrometry (GC-MS). We included 113 species from two grassland plots, quantified their CHCs, and measured their body mass and surface area. We found differences in the surface area, CHCs per body mass and the CHC density (= amount of CHCs per surface area) across the three insect taxa. Especially the Hymenoptera had a higher CHC density compared to Diptera and Lepidoptera. CHC density could be explained by surface area-volume ratios in Hymenoptera but not in Diptera and Lepidoptera. Unexpectedly, CHC density decreased with increasing surface area—volume ratios. PMID:28384308
DOT National Transportation Integrated Search
1984-12-01
This report summarizes work conducted to investigate the feasibility of developing effective countermeasures directed at specific alcohol-related accidents or problems. In Phase I, literature and accident data were reviewed to determine the scope and...
DOT National Transportation Integrated Search
2000-12-01
The current performance-related specifications (PRS) methodology has been under development by the Federal : Highway Administration (FHWA) for several years and has now reached a level at which it can be implemented by : State highway agencies. PRS f...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1979-06-30
The following appendices are included: (1) instruments, (2) electrical specifications, (3) protective coverings, (4) welding requirements, (5) engineering specifications, and (6) administrative. (MOW)
Technical and Occupational Shops. Volume II.
ERIC Educational Resources Information Center
Ontario Dept. of Education, Toronto. School Planning and Building Research Section.
The layouts and specifications provided are intended as a guide to school boards, educators, and architects. Drawings and room plans illustrate specifications for girls' occupational shop, graphic arts, carpentry (millwork and building construction shop), boys' occupational shop (mechanical), boys' occupational shop (building construction),…
Weigh-in-motion (WIM) data for site-specific LRFR bridge load rating.
DOT National Transportation Integrated Search
2011-08-12
The live load factors in the Load and Resistant Factor Rating (LRFR) Manual are based on load data from Ontario : thought to be representative of traffic volumes nationwide. However, in accordance with the methodology for : developing site-specific l...
DOT National Transportation Integrated Search
1984-12-01
This report summarizes work conducted to investigate the feasibility of developing effective countermeasures directed at specific alcohol-related accidents or problems. In Phase I, literature and accident data were reviewed to determine the scope and...
Plexcitonics: Coupled and Plasmon-Exciton Systems with Tailorable Properties
2013-11-14
demonstrated efficient steam generation from aqueous nanoparticles solutions without heating the bulk volume of the liquid. Application in ethanol ...solutions without heating the bulk volume of the liquid. Applications in ethanol distillation and sanitation have been demonstrated. Key Accomplishments...nanoparticle surface. This state-selective population of adsorbate resonances could be exploited to prepare reactants in specific states on nanoparticle
ERIC Educational Resources Information Center
Brainin, Paul A.; And Others
The second of a two-volume report on motor vehicle driving by handicapped persons presents an approach to the evaluation of drivers with 20 specific )edical problems. The guide provides information on symptoms, treatment, guidelines for determining risk levels (risk increasing and risk moderating factors), questions for the applicant, and…
The authors analyzed 44,664 annual measurements of forced vital capacity (FVC) and forced expiratory volume in one second (FEV1) in 12,258 white children and 1,041 black children between 6 and 11 years of age in 6 communities. Sex and race-specific lung function development is de...
Small Business Management. Addendum to Small Business Management Education Curriculum Volume III.
ERIC Educational Resources Information Center
Minnesota Univ., St. Paul. Dept. of Agricultural Education.
A supplement to a previous volume (CE 009 649), this document contains handouts, case problems, schedules, and seminar information keyed to specific units of instruction. The contents by year and unit areas are as follow: year I, unit 1--time management (two-page handout concerning four problems to avoid; year I, unit 2--warranty register (a…
47 CFR 68.317 - Hearing aid compatibility volume control: technical standards.
Code of Federal Regulations, 2011 CFR
2011-10-01
... headset of the telephone, 12 dB of gain minimum and up to 18 dB of gain maximum, when measured in terms of... Instruments With Loop Signaling) . The 12 dB of gain minimum must be achieved without significant clipping of... change in ROLR as a function of the volume control setting that are relevant to the specification of...
47 CFR 68.317 - Hearing aid compatibility volume control: technical standards.
Code of Federal Regulations, 2014 CFR
2014-10-01
... headset of the telephone, 12 dB of gain minimum and up to 18 dB of gain maximum, when measured in terms of... Instruments With Loop Signaling) . The 12 dB of gain minimum must be achieved without significant clipping of... change in ROLR as a function of the volume control setting that are relevant to the specification of...
47 CFR 68.317 - Hearing aid compatibility volume control: technical standards.
Code of Federal Regulations, 2013 CFR
2013-10-01
... headset of the telephone, 12 dB of gain minimum and up to 18 dB of gain maximum, when measured in terms of... Instruments With Loop Signaling) . The 12 dB of gain minimum must be achieved without significant clipping of... change in ROLR as a function of the volume control setting that are relevant to the specification of...
47 CFR 68.317 - Hearing aid compatibility volume control: technical standards.
Code of Federal Regulations, 2012 CFR
2012-10-01
... headset of the telephone, 12 dB of gain minimum and up to 18 dB of gain maximum, when measured in terms of... Instruments With Loop Signaling) . The 12 dB of gain minimum must be achieved without significant clipping of... change in ROLR as a function of the volume control setting that are relevant to the specification of...
47 CFR 68.317 - Hearing aid compatibility volume control: technical standards.
Code of Federal Regulations, 2010 CFR
2010-10-01
... headset of the telephone, 12 dB of gain minimum and up to 18 dB of gain maximum, when measured in terms of... Instruments With Loop Signaling) . The 12 dB of gain minimum must be achieved without significant clipping of... change in ROLR as a function of the volume control setting that are relevant to the specification of...
A practical and sensitive method to assess volatile organic compounds (VOCs) from JP-8 jet fuel in human whole blood was developed by modifying previously established liquid-liquid extraction procedures, optimizing extraction times, solvent volume, specific sample processing te...
ERIC Educational Resources Information Center
Crossley, Michael, Ed.; Vulliamy, Graham, Ed.
This book contains 11 essays that offer in-depth accounts of qualitative research in developing countries. Each chapter focuses upon a specific method and considers related theoretical and practical issues with reference to recent experiences in selected developing countries. Key issues addressed include: (1) the identification of appropriate…
46 CFR 151.45-6 - Maximum amount of cargo.
Code of Federal Regulations, 2010 CFR
2010-10-01
... insulated, or 115 °F if uninsulated. If specific filling densities are designated in Subpart 151.50 of this...=Maximum volume to which tank may be loaded. V =Volume of tank. d r=Density of cargo at the temperature required for a cargo vapor pressure equal to the relief valve setting. d L=Density of cargo at the loading...
ERIC Educational Resources Information Center
Instituto Nacional para la Educacion de los Adultos, Mexico City (Mexico).
The series "Self-instructional Notes on Social Participation" is a six-volume series intended as teaching aids for adult educators. The theoretical, methodological, informative and practical elements of this series will assist professionals in their work and help them achieve greater success. The specific purpose of each notebook is…
46 CFR 151.45-6 - Maximum amount of cargo.
Code of Federal Regulations, 2011 CFR
2011-10-01
... insulated, or 115 °F if uninsulated. If specific filling densities are designated in Subpart 151.50 of this...=Maximum volume to which tank may be loaded. V =Volume of tank. d r=Density of cargo at the temperature required for a cargo vapor pressure equal to the relief valve setting. d L=Density of cargo at the loading...
46 CFR 151.45-6 - Maximum amount of cargo.
Code of Federal Regulations, 2014 CFR
2014-10-01
... insulated, or 115 °F if uninsulated. If specific filling densities are designated in Subpart 151.50 of this...=Maximum volume to which tank may be loaded. V =Volume of tank. d r=Density of cargo at the temperature required for a cargo vapor pressure equal to the relief valve setting. d L=Density of cargo at the loading...
46 CFR 151.45-6 - Maximum amount of cargo.
Code of Federal Regulations, 2013 CFR
2013-10-01
... insulated, or 115 °F if uninsulated. If specific filling densities are designated in Subpart 151.50 of this...=Maximum volume to which tank may be loaded. V =Volume of tank. d r=Density of cargo at the temperature required for a cargo vapor pressure equal to the relief valve setting. d L=Density of cargo at the loading...
ERIC Educational Resources Information Center
Instituto Nacional para la Educacion de los Adultos, Mexico City (Mexico).
The series "Self-instructional Notes on Social Participation" is a six-volume series intended as teaching aids for adult educators. The theoretical, methodological, informative and practical elements of this series will assist professionals in their work and help them achieve greater success. The specific purpose of each notebook is…
Sumowski, James F; Rocca, Maria A; Leavitt, Victoria M; Riccitelli, Gianna; Meani, Alessandro; Comi, Giancarlo; Filippi, Massimo
2016-10-01
Engagement in cognitive leisure activities during early adulthood has been linked to preserved memory and larger hippocampal volume in persons with multiple sclerosis (MS). To investigate which specific types of cognitive leisure activities contribute to hippocampal volume and memory. We investigated links between three types of cognitive activities (Reading-Writing, Art-Music, Games-Hobbies) and (a) hippocampal volume within independent samples of Italian (n=187) and American (n=55) MS patients and (b) memory in subsamples of Italian (n=97) and American (n=53) patients. Reading-Writing was the only predictor of hippocampal volume (rp=.204, p=.002), and the best predictor of memory (rp=.288, p=.001). Findings inform the development of targeted evidence-based enrichment programs aiming to bolster reserve against memory decline. © The Author(s), 2016.
DOE Office of Scientific and Technical Information (OSTI.GOV)
George, J. F.; Richards, D.; Perini, L. L.
1979-05-01
The Applied Physics Laboratory (APL) of the Johns Hopkins University has engineered a baseline design of an Ocean Thermal Energy Conversion (OTEC) pilot plantship. The work was sponsored jointly by the Department of Energy and the US Maritime Administration of the Department of Commerce. The design, drawings, specifications, supporting calculations, and narrative documentation are available through APL for use by the Government and industry for the acquisition of a pilot OTEC system. The baseline design features a platform that is configured to produce up to 20 MW(e) (net) power, using low-cost folded-tube aluminum heat exchangers, while it grazes slowly inmore » tropical waters where the thermal gradient is greatest and the ocean environment is least severe. The design was developed by a team of contractors whose capabilities provided a systems approach to the design process. The work is documented in three volumes. Volume A is the Detailed report, which develops the design rationale, summarizes important calculations, outlines areas for future work, and presents a study of system costs. Volumes B and C, respectively, contain the engineering drawings and specifications.« less
Identifying with fictive characters: structural brain correlates of the personality trait 'fantasy'.
Cheetham, Marcus; Hänggi, Jürgen; Jancke, Lutz
2014-11-01
The perception of oneself as absorbed in the thoughts, feelings and happenings of a fictive character (e.g. in a novel or film) as if the character's experiences were one's own is referred to as identification. We investigated whether individual variation in the personality trait of identification is associated with individual variation in the structure of specific brain regions, using surface and volume-based morphometry. The hypothesized regions of interest were selected on the basis of their functional role in subserving the cognitive processing domains considered important for identification (i.e. mental imagery, empathy, theory of mind and merging) and for the immersive experience called 'presence'. Controlling for age, sex, whole-brain volume and other traits, identification covaried significantly with the left hippocampal volume, cortical thickness in the right anterior insula and the left dorsal medial prefrontal cortex, and with gray matter volume in the dorsolateral prefrontal cortex. These findings show that trait identification is associated with structural variation in specific brain regions. The findings are discussed in relation to the potential functional contribution of these regions to identification. © The Author (2014). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.
Voxel-based morphometry study of the insular cortex in bipolar depression.
Tang, Li-Rong; Liu, Chun-Hong; Jing, Bin; Ma, Xin; Li, Hai-Yun; Zhang, Yu; Li, Feng; Wang, Yu-Ping; Yang, Zhi; Wang, Chuan-Yue
2014-11-30
Bipolar depression (BD) is a common psychiatric illness characterized by deficits in emotional and cognitive processing. Abnormalities in the subregions of the insula are common findings in neuroanatomical studies of patients with bipolar disorder. However, the specific relationships between morphometric changes in specific insular subregions and the pathogenesis of BD are not clear. In this study, structural magnetic resonance imaging (MRI) was used to investigate gray matter volume abnormalities in the insular subregion in 27 patients with BD and in 27 age and sex-matched controls. Using DARTEL (diffeomorphic anatomical registration through exponentiated lie algebra) for voxel-based morphometry (VBM), we examined changes in regional gray matter volumes of the insula in patients with BD. As compared with healthy controls, the BD patients showed decreased gray matter volumes in the right posterior insula and left ventral anterior insula and increased gray matter volumes in the left dorsal anterior insula. Consistent with the emerging theory of insular interference as a contributor to emotional-cognitive dysregulation, the current findings suggest that the insular cortex may be involved in the neural substrates of BD. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Self-efficacy is independently associated with brain volume in older women.
Davis, Jennifer C; Nagamatsu, Lindsay S; Hsu, Chun Liang; Beattie, B Lynn; Liu-Ambrose, Teresa
2012-07-01
ageing is highly associated with neurodegeneration and atrophy of the brain. Evidence suggests that personality variables are risk factors for reduced brain volume. We examine whether falls-related self-efficacy is independently associated with brain volume. a cross-sectional analysis of whether falls-related self-efficacy is independently associated with brain volumes (total, grey and white matter). Three multivariate regression models were constructed. Covariates included in the models were age, global cognition, systolic blood pressure, functional comorbidity index and current physical activity level. MRI scans were acquired from 79 community-dwelling senior women aged 65-75 years old. Falls-related self-efficacy was assessed by the activities-specific balance confidence (ABC) scale. after accounting for covariates, falls-related self-efficacy was independently associated with both total brain volume and total grey matter volume. The final model for total brain volume accounted for 17% of the variance, with the ABC score accounting for 8%. For total grey matter volume, the final model accounted for 24% of the variance, with the ABC score accounting for 10%. we provide novel evidence that falls-related self-efficacy, a modifiable risk factor for healthy ageing, is positively associated with total brain volume and total grey matter volume. ClinicalTrials.gov Identifier: NCT00426881.
Self-efficacy is independently associated with brain volume in older women
Davis, Jennifer C.; Nagamatsu, Lindsay S.; Hsu, Chun Liang; Beattie, B. Lynn; Liu-Ambrose, Teresa
2015-01-01
Background Aging is highly associated with neurodegeneration and atrophy of the brain. Evidence suggests that personality variables are risk factors for reduced brain volume. We examine whether falls-related self-efficacy is independently associated with brain volume. Method A cross-sectional analysis of whether falls-related self-efficacy is independently associated with brain volumes (total, grey, and white matter). Three multivariate regression models were constructed. Covariates included in the models were age, global cognition, systolic blood pressure, functional comorbidity index, and current physical activity level. MRI scans were acquired from 79 community-dwelling senior women aged 65 to 75 years old. Falls-related self-efficacy was assessed by the Activities Specific Balance Confidence (ABC) Scale. Results After accounting for covariates, falls-related self-efficacy was independently associated with both total brain volume and total grey matter volume. The final model for total brain volume accounted for 17% of the variance, with the ABC score accounting for 8%. For total grey matter volume, the final model accounted for 24% of the variance, with the ABC score accounting for 10%. Conclusion We provide novel evidence that falls-related self-efficacy, a modifiable risk factor for healthy aging, is positively associated with total brain volume and total grey matter volume. Trial Registration ClinicalTrials.gov Identifier: NCT00426881. PMID:22436405
Disability-Specific Atlases of Gray Matter Loss in Relapsing-Remitting Multiple Sclerosis.
MacKenzie-Graham, Allan; Kurth, Florian; Itoh, Yuichiro; Wang, He-Jing; Montag, Michael J; Elashoff, Robert; Voskuhl, Rhonda R
2016-08-01
Multiple sclerosis (MS) is characterized by progressive gray matter (GM) atrophy that strongly correlates with clinical disability. However, whether localized GM atrophy correlates with specific disabilities in patients with MS remains unknown. To understand the association between localized GM atrophy and clinical disability in a biology-driven analysis of MS. In this cross-sectional study, magnetic resonance images were acquired from 133 women with relapsing-remitting MS and analyzed using voxel-based morphometry and volumetry. A regression analysis was used to determine whether voxelwise GM atrophy was associated with specific clinical deficits. Data were collected from June 28, 2007, to January 9, 2014. Voxelwise correlation of GM change with clinical outcome measures (Expanded Disability Status Scale and Multiple Sclerosis Functional Composite scores). Among the 133 female patients (mean [SD] age, 37.4 [7.5] years), worse performance on the Multiple Sclerosis Functional Composite correlated with voxelwise GM volume loss in the middle cingulate cortex (P < .001) and a cluster in the precentral gyrus bilaterally (P = .004). In addition, worse performance on the Paced Auditory Serial Addition Test correlated with volume loss in the auditory and premotor cortices (P < .001), whereas worse performance on the 9-Hole Peg Test correlated with GM volume loss in Brodmann area 44 (Broca area; P = .02). Finally, voxelwise GM loss in the right paracentral lobulus correlated with bowel and bladder disability (P = .03). Thus, deficits in specific clinical test results were directly associated with localized GM loss in clinically eloquent locations. These biology-driven data indicate that specific disabilities in MS are associated with voxelwise GM loss in distinct locations. This approach may be used to develop disability-specific biomarkers for use in future clinical trials of neuroprotective treatments in MS.
GPS Space Service Volume: Ensuring Consistent Utility Across GPS Design Builds for Space Users
NASA Technical Reports Server (NTRS)
Bauer, Frank H.; Parker, Joel Jefferson Konkl; Valdez, Jennifer Ellen
2015-01-01
GPS availability and signal strength originally specified for users on or near surface of Earth with transmitted power levels specified at edge-of-Earth, 14.3 degrees. Prior to the SSV specification, on-orbit performance of GPS varied from block build to block build (IIA, IIRM, IIF) due to antenna gain and beam width variances. Unstable on-orbit performance results in significant risk to space users. Side-lobe signals, although not specified, were expected to significantly boost GPS signal availability for users above the constellation. During GPS III Phase A, NASA noted significant discrepancies in power levels specified in GPS III specification documents, and measured on-orbit performance. To stabilize the signal for high altitude space users, NASA DoD team in 2003-2005 led the creation of new Space Service Volume (SSV) definition and specifications.
NASA Astrophysics Data System (ADS)
An, Geon-Hyoung; Ahn, Hyo-Jin; Hong, Woong-Ki
2015-01-01
Four different types of carbon nanofibers (CNFs) for electrical double-layer capacitors (EDLCs), porous and non-porous CNFs with and without Pt metal nanoparticles, are synthesized by an electrospinning method and their performance in electrical double-layer capacitors (EDLCs) is characterized. In particular, the Pt-embedded porous CNFs (PCNFs) exhibit a high specific surface area of 670 m2 g-1, a large mesopore volume of 55.7%, and a low electrical resistance of 1.7 × 103. The synergistic effects of the high specific surface area with a large mesopore volume, and superior electrical conductivity result in an excellent specific capacitance of 130.2 F g-1, a good high-rate performance, superior cycling durability, and high energy density of 16.9-15.4 W h kg-1 for the performance of EDLCs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lafata, K; Ren, L; Wu, Q
Purpose: To develop a data-mining methodology based on quantum clustering and machine learning to predict expected dosimetric endpoints for lung SBRT applications based on patient-specific anatomic features. Methods: Ninety-three patients who received lung SBRT at our clinic from 2011–2013 were retrospectively identified. Planning information was acquired for each patient, from which various features were extracted using in-house semi-automatic software. Anatomic features included tumor-to-OAR distances, tumor location, total-lung-volume, GTV and ITV. Dosimetric endpoints were adopted from RTOG-0195 recommendations, and consisted of various OAR-specific partial-volume doses and maximum point-doses. First, PCA analysis and unsupervised quantum-clustering was used to explore the feature-space tomore » identify potentially strong classifiers. Secondly, a multi-class logistic regression algorithm was developed and trained to predict dose-volume endpoints based on patient-specific anatomic features. Classes were defined by discretizing the dose-volume data, and the feature-space was zero-mean normalized. Fitting parameters were determined by minimizing a regularized cost function, and optimization was performed via gradient descent. As a pilot study, the model was tested on two esophageal dosimetric planning endpoints (maximum point-dose, dose-to-5cc), and its generalizability was evaluated with leave-one-out cross-validation. Results: Quantum-Clustering demonstrated a strong separation of feature-space at 15Gy across the first-and-second Principle Components of the data when the dosimetric endpoints were retrospectively identified. Maximum point dose prediction to the esophagus demonstrated a cross-validation accuracy of 87%, and the maximum dose to 5cc demonstrated a respective value of 79%. The largest optimized weighting factor was placed on GTV-to-esophagus distance (a factor of 10 greater than the second largest weighting factor), indicating an intuitively strong correlation between this feature and both endpoints. Conclusion: This pilot study shows that it is feasible to predict dose-volume endpoints based on patient-specific anatomic features. The developed methodology can potentially help to identify patients at risk for higher OAR doses, thus improving the efficiency of treatment planning. R01-184173.« less
Does hydration status affect MRI measures of brain volume or water content?
Meyers, Sandra M; Tam, Roger; Lee, Jimmy S; Kolind, Shannon H; Vavasour, Irene M; Mackie, Emilie; Zhao, Yinshan; Laule, Cornelia; Mädler, Burkhard; Li, David K B; MacKay, Alex L; Traboulsee, Anthony L
2016-08-01
To determine whether differences in hydration state, which could arise from routine clinical procedures such as overnight fasting, affect brain total water content (TWC) and brain volume measured with magnetic resonance imaging (MRI). Twenty healthy volunteers were scanned with a 3T MR scanner four times: day 1, baseline scan; day 2, hydrated scan after consuming 3L of water over 12 hours; day 3, dehydrated scan after overnight fasting of 9 hours, followed by another scan 1 hour later for reproducibility. The following MRI data were collected: T2 relaxation (for TWC measurement), inversion recovery (for T1 measurement), and 3D T1 -weighted (for brain volumes). Body weight and urine specific gravity were also measured. TWC was calculated by fitting the T2 relaxation data with a nonnegative least-squares algorithm, with corrections for T1 relaxation and image signal inhomogeneity and normalization to ventricular cerebrospinal fluid. Brain volume changes were measured using SIENA. TWC means were calculated within 14 tissue regions. Despite indications of dehydration as demonstrated by increases in urine specific gravity (P = 0.03) and decreases in body weight (P = 0.001) between hydrated and dehydrated scans, there was no measurable change in TWC (within any brain region) or brain volume between hydration states. We demonstrate that within a range of physiologic conditions commonly encountered in routine clinical scans (no pretreatment with hydration, well hydrated before MRI, and overnight fasting), brain TWC and brain volumes are not substantially affected in a healthy control cohort. J. Magn. Reson. Imaging 2016;44:296-304. © 2016 Wiley Periodicals, Inc.
Bivariate analysis of floods in climate impact assessments.
Brunner, Manuela Irene; Sikorska, Anna E; Seibert, Jan
2018-03-01
Climate impact studies regarding floods usually focus on peak discharges and a bivariate assessment of peak discharges and hydrograph volumes is not commonly included. A joint consideration of peak discharges and hydrograph volumes, however, is crucial when assessing flood risks for current and future climate conditions. Here, we present a methodology to develop synthetic design hydrographs for future climate conditions that jointly consider peak discharges and hydrograph volumes. First, change factors are derived based on a regional climate model and are applied to observed precipitation and temperature time series. Second, the modified time series are fed into a calibrated hydrological model to simulate runoff time series for future conditions. Third, these time series are used to construct synthetic design hydrographs. The bivariate flood frequency analysis used in the construction of synthetic design hydrographs takes into account the dependence between peak discharges and hydrograph volumes, and represents the shape of the hydrograph. The latter is modeled using a probability density function while the dependence between the design variables peak discharge and hydrograph volume is modeled using a copula. We applied this approach to a set of eight mountainous catchments in Switzerland to construct catchment-specific and season-specific design hydrographs for a control and three scenario climates. Our work demonstrates that projected climate changes have an impact not only on peak discharges but also on hydrograph volumes and on hydrograph shapes both at an annual and at a seasonal scale. These changes are not necessarily proportional which implies that climate impact assessments on future floods should consider more flood characteristics than just flood peaks. Copyright © 2017. Published by Elsevier B.V.
Carmichael, Owen; Xie, Jing; Fletcher, Evan; Singh, Baljeet; DeCarli, Charles
2012-06-01
Hippocampal injury in the Alzheimer's disease (AD) pathological process is region-specific and magnetic resonance imaging (MRI)-based measures of localized hippocampus (HP) atrophy are known to detect region-specific changes associated with clinical AD, but it is unclear whether these measures provide information that is independent of that already provided by measures of total HP volume. Therefore, this study assessed the strength of association between localized HP atrophy measures and AD-related measures including cerebrospinal fluid (CSF) amyloid beta and tau concentrations, and cognitive performance, in statistical models that also included total HP volume as a covariate. A computational technique termed localized components analysis (LoCA) was used to identify 7 independent patterns of HP atrophy among 390 semiautomatically delineated HP from baseline magnetic resonance imaging of participants in the Alzheimer's Disease Neuroimaging Initiative (ADNI). Among cognitively normal participants, multiple measures of localized HP atrophy were significantly associated with CSF amyloid concentration, while total HP volume was not. In addition, among all participants, localized HP atrophy measures and total HP volume were both independently and additively associated with CSF tau concentration, performance on numerous neuropsychological tests, and discrimination between normal, mild cognitive impairment (MCI), and AD clinical diagnostic groups. Together, these results suggest that regional measures of hippocampal atrophy provided by localized components analysis may be more sensitive than total HP volume to the effects of AD pathology burden among cognitively normal individuals and may provide information about HP regions whose deficits may have especially profound cognitive consequences throughout the AD clinical course. Copyright © 2012 Elsevier Inc. All rights reserved.
Semantic layers for illustrative volume rendering.
Rautek, Peter; Bruckner, Stefan; Gröller, Eduard
2007-01-01
Direct volume rendering techniques map volumetric attributes (e.g., density, gradient magnitude, etc.) to visual styles. Commonly this mapping is specified by a transfer function. The specification of transfer functions is a complex task and requires expert knowledge about the underlying rendering technique. In the case of multiple volumetric attributes and multiple visual styles the specification of the multi-dimensional transfer function becomes more challenging and non-intuitive. We present a novel methodology for the specification of a mapping from several volumetric attributes to multiple illustrative visual styles. We introduce semantic layers that allow a domain expert to specify the mapping in the natural language of the domain. A semantic layer defines the mapping of volumetric attributes to one visual style. Volumetric attributes and visual styles are represented as fuzzy sets. The mapping is specified by rules that are evaluated with fuzzy logic arithmetics. The user specifies the fuzzy sets and the rules without special knowledge about the underlying rendering technique. Semantic layers allow for a linguistic specification of the mapping from attributes to visual styles replacing the traditional transfer function specification.
DOT National Transportation Integrated Search
1984-12-01
This report summarizes work conducted to investigate the feasibility of developing effective countermeasures directed at specific alcohol-related accidents or problems. In Phase I, literature and accident data were reviewed to determine the scope and...
Lin, Muyang; Tay, Siang Hong; Yang, Hongshun; Yang, Bao; Li, Hongliang
2017-08-15
To evaluate the feasibility of substituting eggs in yellow cake by a mixture of soybean proteins, plant polysaccharides, and emulsifiers, the batter properties, including specific gravity and viscosity; cake properties, including specific volume, texture, colour, moisture, microstructures, and structural properties of starch and glutens of the replaced cake and traditional cake containing egg, were evaluated. Replacing eggs with a soy protein isolate and 1% mono-, di-glycerides yielded a similar specific volume, specific gravity, firmness and moisture content (1.92 vs. 2.08cm 3 /g, 0.95 vs. 1.03, 319.8 vs. 376.1g, and 28.03% vs. 29.01%, respectively) compared with the traditional cakes baked with eggs. Structurally, this formulation comprised dominant gliadin aggregates in the size range of 100-200nm and glutenin networking structures containing fewer but larger porosities. The results suggest that a mixture of soybean proteins and emulsifier is a promising substitute for eggs in cakes. Copyright © 2017 Elsevier Ltd. All rights reserved.
Philippi, Nathalie; Botzung, Anne; Noblet, Vincent; Rousseau, François; Després, Olivier; Cretin, Benjamin; Kremer, Stéphane; Blanc, Frédéric; Manning, Liliann
2015-01-01
We studied the influence of emotions on autobiographical memory (AbM) in patients with Alzheimer's disease (AD), characteristically triggering atrophy in the hippocampus and the amygdala, two crucial structures sustaining memory and emotional processing. Our first aim was to analyze the influence of emotion on AbM in AD patients, on both the proportion and the specificity of emotional memories. Additionally, we sought to determine the relationship of emotional AbM to amygdalar-hippocampal volumes. Eighteen prodromal to mild AD patients and 18 age-matched healthy controls were included. We obtained 30 autobiographical memories per participant using the modified Crovitz test (MCT). Analyses were performed on global scores, rates and specificity scores of the emotional vs. neutral categories of memories. Amygdalar-hippocampal volumes were extracted from 3D T1-weighted MRI scans and tested for correlations with behavioral data. Overall, AD patients displayed a deficit in emotional AbMs as they elicited less emotional memories than the controls, however, the specificity of those memories was preserved. The deficit likely implied retrieval or storage as it was extended in time and without reminiscence bump effect. Global scores and rates of emotional memories, but not the specificity scores, were correlated to right amygdalar and hippocampal volumes, indicating that atrophy in these structures has a central role in the deficit observed. Conversely, emotional memories were more specific than neutral memories in both groups, reflecting an enhancement effect of emotion that could be supported by other brain regions that are spared during the early stages of the disease.
Space station needs, attributes and architectural options study. Volume 3: Requirements
NASA Technical Reports Server (NTRS)
1983-01-01
A typical system specification format is presented and requirements are compiled. A Program Specification Tree is shown showing a high inclination space station and a low inclination space station with their typical element breakdown, also represented along the top blocks are the interfaces with other systems. The specification format is directed at the Low Inclination space station.
McNeill, K S; Cancilla, D A
2009-03-01
Soil samples from three USA airports representing low, mid, and large volume users of aircraft deicing fluids (ADAFs) were analyzed by LC/MS/MS for the presence of triazoles, a class of corrosion inhibitors historically used in ADAFs. Triazoles, specifically the 4-methyl-1H-benzotriazole and the 5-methyl-1H-benzotriazole, were detected in a majority of samples and ranged from 2.35 to 424.19 microg/kg. Previous studies have focused primarily on ground and surface water impacts of larger volume ADAF users. The detection of triazoles in soils at low volume ADAF use airports suggests that deicing activities may have a broader environmental impact than previously considered.
Cost and price estimate of Brayton and Stirling engines in selected production volumes
NASA Technical Reports Server (NTRS)
Fortgang, H. R.; Mayers, H. F.
1980-01-01
The methods used to determine the production costs and required selling price of Brayton and Stirling engines modified for use in solar power conversion units are presented. Each engine part, component and assembly was examined and evaluated to determine the costs of its material and the method of manufacture based on specific annual production volumes. Cost estimates are presented for both the Stirling and Brayton engines in annual production volumes of 1,000, 25,000, 100,000 and 400,000. At annual production volumes above 50,000 units, the costs of both engines are similar, although the Stirling engine costs are somewhat lower. It is concluded that modifications to both the Brayton and Stirling engine designs could reduce the estimated costs.
Ambient occlusion effects for combined volumes and tubular geometry.
Schott, Mathias; Martin, Tobias; Grosset, A V Pascal; Smith, Sean T; Hansen, Charles D
2013-06-01
This paper details a method for interactive direct volume rendering that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube-shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The algorithm extends the recently presented the directional occlusion shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. Stream tube geometries are computed using an effective spline-based interpolation and approximation scheme that avoids self-intersection and maintains coherent orientation of the stream tube segments to avoid surface deforming twists. Furthermore, strategies to reduce the geometric and specular aliasing of the stream tubes are discussed.
Ambient Occlusion Effects for Combined Volumes and Tubular Geometry
Schott, Mathias; Martin, Tobias; Grosset, A.V. Pascal; Smith, Sean T.; Hansen, Charles D.
2013-01-01
This paper details a method for interactive direct volume rendering that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube-shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The algorithm extends the recently presented the directional occlusion shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. Stream tube geometries are computed using an effective spline-based interpolation and approximation scheme that avoids self-intersection and maintains coherent orientation of the stream tube segments to avoid surface deforming twists. Furthermore, strategies to reduce the geometric and specular aliasing of the stream tubes are discussed. PMID:23559506
Lim, Nicholas R; Shohayeb, Belal; Zaytseva, Olga; Mitchell, Naomi; Millard, S Sean; Ng, Dominic C H; Quinn, Leonie M
2017-07-11
The second most commonly mutated gene in primary microcephaly (MCPH) patients is wd40-repeat protein 62 (wdr62), but the relative contribution of WDR62 function to the growth of major brain lineages is unknown. Here, we use Drosophila models to dissect lineage-specific WDR62 function(s). Interestingly, although neural stem cell (neuroblast)-specific depletion of WDR62 significantly decreased neuroblast number, brain size was unchanged. In contrast, glial lineage-specific WDR62 depletion significantly decreased brain volume. Moreover, loss of function in glia not only decreased the glial population but also non-autonomously caused neuroblast loss. We further demonstrated that WDR62 controls brain growth through lineage-specific interactions with master mitotic signaling kinase, AURKA. Depletion of AURKA in neuroblasts drives brain overgrowth, which was suppressed by WDR62 co-depletion. In contrast, glial-specific depletion of AURKA significantly decreased brain volume, which was further decreased by WDR62 co-depletion. Thus, dissecting relative contributions of MCPH factors to individual neural lineages will be critical for understanding complex diseases such as microcephaly. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
Chaim, Tiffany M; Schaufelberger, Maristela S; Ferreira, Luiz K; Duran, Fábio L S; Ayres, Adriana M; Scazufca, Marcia; Menezes, Paulo R; Amaro, Edson; Leite, Claudia C; Murray, Robin M; McGuire, Philip K; Rushe, Teresa M; Busatto, Geraldo F
2010-10-30
The present study aimed to investigate the presence of corpus callosum (CC) volume deficits in a population-based recent-onset psychosis (ROP) sample, and whether CC volume relates to interhemispheric communication deficits. For this purpose, we used voxel-based morphometry comparisons of magnetic resonance imaging data between ROP (n =122) and healthy control (n = 94) subjects. Subgroups (38 ROP and 39 controls) were investigated for correlations between CC volumes and performance on the Crossed Finger Localization Test (CFLT). Significant CC volume reductions in ROP subjects versus controls emerged after excluding substance misuse and non-right-handedness. CC reductions retained significance in the schizophrenia subgroup but not in affective psychoses subjects. There were significant positive correlations between CC volumes and CFLT scores in ROP subjects, specifically in subtasks involving interhemispheric communication. From these results, we can conclude that CC volume reductions are present in association with ROP. The relationship between such deficits and CFLT performance suggests that interhemispheric communication impairments are directly linked to CC abnormalities in ROP. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Foundations for Measuring Volume Rendering Quality
NASA Technical Reports Server (NTRS)
Williams, Peter L.; Uselton, Samuel P.; Chancellor, Marisa K. (Technical Monitor)
1997-01-01
The goal of this paper is to provide a foundation for objectively comparing volume rendered images. The key elements of the foundation are: (1) a rigorous specification of all the parameters that need to be specified to define the conditions under which a volume rendered image is generated; (2) a methodology for difference classification, including a suite of functions or metrics to quantify and classify the difference between two volume rendered images that will support an analysis of the relative importance of particular differences. The results of this method can be used to study the changes caused by modifying particular parameter values, to compare and quantify changes between images of similar data sets rendered in the same way, and even to detect errors in the design, implementation or modification of a volume rendering system. If one has a benchmark image, for example one created by a high accuracy volume rendering system, the method can be used to evaluate the accuracy of a given image.
Characterization of fluid physics effects on cardiovascular response to microgravity (G-572)
NASA Technical Reports Server (NTRS)
Pantalos, George M.; Bennett, Thomas E.; Sharp, M. Keith; Woodruff, Stewart; Oleary, Sean; Gillars, Kevin; Lemon, Mark; Sojka, Jan
1995-01-01
The investigation of cardiovascular adaptation to space flight has seen substantial advancement in the last several years. In-flight echocardiographic measurements of astronaut cardiac function on the Space Shuttle have documented an initial increase, followed by a progressive reduction in both left ventricular volume index and stroke volume with a compensatory increase in heart rate to maintain cardiac output. To date, the reduced cardiac size and stroke volume have been presumed to be the consequence of the reduction in circulating fluid volume within a few days after orbital insertion. However, no specific mechanism for the reduced stroke volume has been identified. The following investigation proposes the use of a hydraulic model of the cardiovascular system to examine the possibility that the observed reduction in stroke volume may, in part, be related to fluid physics effects on heart function. The automated model is being prepared to fly as a Get Away Special (GAS) payload within the next year.
Sahin, Hilal; Sarioglu, Fatma Ceren; Bagci, Mustafa; Karadeniz, Tugba; Uluer, Hatice; Sanci, Muzaffer
2018-05-01
The aim of this retrospective single-center study was to evaluate the relationship between maximum tumor size, tumor volume, tumor volume ratio (TVR) based on preoperative magnetic resonance (MR) volumetry, and negative histological prognostic parameters (deep myometrial invasion [MI], lymphovascular space invasion, tumor histological grade, and subtype) in International Federation of Gynecology and Obstetrics stage I endometrial cancer. Preoperative pelvic MR imaging studies of 68 women with surgical-pathologic diagnosis of International Federation of Gynecology and Obstetrics stage I endometrial cancer were reviewed for assessment of MR volumetry and qualitative assessment of MI. Volume of the tumor and uterus was measured with manual tracing of each section on sagittal T2-weighted images. Tumor volume ratio was calculated according to the following formula: TVR = (total tumor volume/total uterine volume) × 100. Receiver operating characteristics curve was performed to investigate a threshold for TVR associated with MI. The Mann-Whitney U test, Kruskal-Wallis test, and linear regression analysis were applied to evaluate possible differences between tumor size, tumor volume, TVR, and negative prognostic parameters. Receiver operating characteristics curve analysis of TVR for prediction of deep MI was statistically significant (P = 0.013). An optimal TVR threshold of 7.3% predicted deep myometrial invasion with 85.7% sensitivity, 46.8% specificity, 41.9% positive predictive value, and 88.0% negative predictive value. Receiver operating characteristics curve analyses of TVR, tumor size, and tumor volume for prediction of tumor histological grade or lymphovascular space invasion were not significant. The concordance between radiologic and pathologic assessment for MI was almost excellent (κ value, 0.799; P < 0.001). Addition of TVR to standard radiologic assessment of deep MI increased the sensitivity from 90.5% to 95.2%. Tumor volume ratio, based on preoperative MR volumetry, seems to predict deep MI independently in stage I endometrial cancer with insufficient sensitivity and specificity. Its value in clinical practice for risk stratification models in endometrial cancer has to be studied in larger cohort of patients.
Rouhani, S. Zia
1996-10-22
The state of charge of electrochemical batteries of different kinds is determined by measuring the incremental change in the total volume of the reactive masses in the battery. The invention is based on the principle that all electrochemical batteries, either primary or secondary (rechargeable), produce electricity through a chemical reaction with at least one electrode, and the chemical reactions produce certain changes in the composition and density of the electrode. The reactive masses of the electrodes, the electrolyte, and any separator or spacers are usually contained inside a battery casing of a certain volume. As the battery is used, or recharged, the specific volume of at least one of the electrode masses will change and, since the masses of the materials do not change considerably, the total volume occupied by at least one of the electrodes will change. These volume changes may be measured in many different ways and related to the state of charge in the battery. In one embodiment, the volume change can be measured by monitoring the small changes in one of the principal dimensions of the battery casing as it expands or shrinks to accommodate the combined volumes of its components.
Palmen, Saskia J M C; Hulshoff Pol, Hilleke E; Kemner, Chantal; Schnack, Hugo G; Durston, Sarah; Lahuis, Bertine E; Kahn, René S; Van Engeland, Herman
2005-04-01
To establish whether high-functioning children with autism spectrum disorder (ASD) have enlarged brains in later childhood, and if so, whether this enlargement is confined to the gray and/or to the white matter and whether it is global or more prominent in specific brain regions. Brain MRI scans were acquired from 21 medication-naive, high-functioning children with ASD between 7 and 15 years of age and 21 comparison subjects matched for gender, age, IQ, height, weight, handedness, and parental education, but not pubertal status. Patients showed a significant increase of 6% in intracranium, total brain, cerebral gray matter, cerebellum, and of more than 40% in lateral and third ventricles compared to controls. The cortical gray-matter volume was evenly affected in all lobes. After correction for brain volume, ventricular volumes remained significantly larger in patients. High-functioning children with ASD showed a global increase in gray-matter, but not white-matter and cerebellar volume, proportional to the increase in brain volume, and a disproportional increase in ventricular volumes, still present after correction for brain volume. Advanced pubertal development in the patients compared to the age-matched controls may have contributed to the findings reported in the present study.
NASA Technical Reports Server (NTRS)
Narvet, Steven W.; Frigm, Ryan C.; Hejduk, Matthew D.
2011-01-01
Conjunction Assessment operations require screening assets against the space object catalog by placing a pre-determined spatial volume around each asset and predicting when another object will violate that volume. The selection of the screening volume used for each spacecraft is a trade-off between observing all conjunction events that may pose a potential risk to the primary spacecraft and the ability to analyze those predicted events. If the screening volumes are larger, then more conjunctions can be observed and therefore the probability of a missed detection of a high risk conjunction event is small; however, the amount of data which needs to be analyzed increases. This paper characterizes the sensitivity of screening volume size to capturing typical orbit uncertainties and the expected number of conjunction events observed. These sensitivities are quantified in the form of a trade space that allows for selection of appropriate screen-ing volumes to fit the desired concept of operations, system limitations, and tolerable analyst workloads. This analysis will specifically highlight the screening volume determination and selection process for use in the NASA Conjunction Assessment Risk Analysis process but will also provide a general framework for other Owner / Operators faced with similar decisions.
An operator calculus for surface and volume modeling
NASA Technical Reports Server (NTRS)
Gordon, W. J.
1984-01-01
The mathematical techniques which form the foundation for most of the surface and volume modeling techniques used in practice are briefly described. An outline of what may be termed an operator calculus for the approximation and interpolation of functions of more than one independent variable is presented. By considering the linear operators associated with bivariate and multivariate interpolation/approximation schemes, it is shown how they can be compounded by operator multiplication and Boolean addition to obtain a distributive lattice of approximation operators. It is then demonstrated via specific examples how this operator calculus leads to practical techniques for sculptured surface and volume modeling.
Shock melting and vaporization of metals.
NASA Technical Reports Server (NTRS)
Ahrens, T. J.
1972-01-01
The effect of initial porosity on shock induction of melting and vaporization is investigated for Ba, Sr, Li, Fe, Al, U, and Th. For the less compressible of these metals, it is found that for a given strong shock-generation system (explosive in contact, or flyer-plate impact) an optimum initial specific volume exists such that the total entropy production, and hence the amount of metal liquid or vapor, is a maximum. Initial volumes from 1.4 to 2.0 times crystal volumes, depending on the metal sample and shock-inducing system, will result in optimum post-shock entropies.
ERIC Educational Resources Information Center
United Nations Educational, Scientific, and Cultural Organization, Bangkok (Thailand). Regional Office for Education in Asia and the Pacific.
This handbook, the second volume in a series of three publications on distance education, presents guidelines on structures and strategies in organizations and the processes of materials development. A checklist of specific items is included for each topic addressed. The first guidelines are addressed to policymakers and senior administrators and…
ERIC Educational Resources Information Center
Hodges, Walter L.; And Others
This volume describes and discusses six major proposals for a complete model system of day care for indigent children in West Virginia. The recommendations include: (1) developing more specific objectives to be accomplished for children, parents, care providers, and the state; (2) developing a public education program designed to help parents…
ERIC Educational Resources Information Center
Instituto Nacional para la Educacion de los Adultos, Mexico City (Mexico).
The series "Self-instructional Notes on Social Participation" is a six volume series intended as teaching aids for adult educators. The theoretical, methodological, informative and practical elements of this series will assist professionals in their work and help them achieve greater success. The specific purpose of each notebook is…
Evaluation of the Field Test of Project Information Packages: Volume III--Resource Cost Analysis.
ERIC Educational Resources Information Center
Al-Salam, Nabeel; And Others
The third of three volumes evaluating the first year field test of the Project Information Packages (PIPs) provides a cost analysis study as a key element in the total evaluation. The resource approach to cost analysis is explained and the specific resource methodology used in the main cost analysis of the 19 PIP field-test projects detailed. The…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-08
... accordance with a sliding scale that takes account of overall market volumes during the month. Specifically... consolidated volume is 8 billion or fewer shares per day during the month. Effective March 1, 2011, NASDAQ will... Section 19(b)(1) of the Securities Exchange Act of 1934 (``Act'') \\1\\ and Rule 19b-4 thereunder,\\2\\ notice...
High-Performance Home Technologies: Solar Thermal & Photovoltaic Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baechler, M.; Gilbride, T.; Ruiz, K.
This document is the sixth volume of the Building America Best Practices Series. It presents information that is useful throughout the United States for enhancing the energy efficiency practices in the specific climate zones that are presented in the first five Best Practices volumes. It provides an introduction to current photovoltaic and solar thermal building practices. Information about window selection and shading is included.
ERIC Educational Resources Information Center
Neave, Guy, Ed.; van Vught, Frans A., Ed.
This volume collects several case studies on the relationship between government and higher education in developing nations in Africa, Asia, and Latin America. In particular these studies ask whether specific forms of government regulation help to solve the crisis of higher education in the developing world better than other forms of regulation.…
Sex Differences in Brain Volume Are Related to Specific Skills, Not to General Intelligence
ERIC Educational Resources Information Center
Burgaleta, Miguel; Head, Kevin; Alvarez-Linera, Juan; Martinez, Kenia; Escorial, Sergio; Haier, Richard; Colom, Roberto
2012-01-01
It has been proposed that males would show higher mean scores than females in general intelligence ("g") because (1) men have, on average, larger brains than women, and (2) brain volume correlates with "g." Here we report a failure to support the conclusion derived from these premises. High resolution MRIs were acquired in a sample of one hundred…
ERIC Educational Resources Information Center
Congress of the U.S., Washington, DC. House Committee on Education and Labor.
This volume is a compilation of the texts of nine Federal education laws, specifically vocational education, job training, rehabilitation, and related statutes. Part I contains one law related to vocational education--the Carl D. Perkins Vocational Education Act 1984 (originally, Vocational Education Act of 1963). Part II provides the texts of six…
NASA Astrophysics Data System (ADS)
Khlebtsov, Boris N.; Burygin, Gennadii L.; Matora, Larisa Y.; Shchyogolev, Sergei Y.; Khlebtsov, Nikolai G.
2004-07-01
We describe two variants of a method for determining the average composition of insoluble immune complex particles (IICP). The first variant is based on measuring the specific turbidity (the turbidity per unit mass concentration of the dispersed substance) and the average size of IICP determined from dynamic light scattering (DLS). In the second variant, the wavelength exponent (i.e., the slope of the logarithmic turbidity spectrum) is used in combination with specific turbidity measurements. Both variants allow the average biopolymer volume fraction to be determined in terms of the average refractive index of IICP. The method is exemplified by two experimental antigen+antibody systems: (i) lipopolysaccharide-protein complex (LPPC) of Azospirillum brasilense Sp245+rabbit anti-LPPC; and (ii) human IgG (hIgG)+sheep anti-hIgG. Our measurements by the two methods for both types of systems gave, on the average, the same result: the volume fraction of the IICP biopolymers is about 30%; accordingly, the volume fraction of buffer solvent is 70%.
Jayanthi, Neeru; Esser, Stephen
2013-01-01
Tennis may be considered a static and dynamic form of exercise with many well-demonstrated health benefits. Tennis has similar rates of injury to other individual recreational sports and junior competitive sports, without the catastrophic risk of contact/collision sports. Classifying tennis players into junior and elite categories versus adult recreational players may help in outlining volume of play recommendations, exposure risk, and types of injuries. Junior and elite players tend to tolerate higher volumes, have more acute and lower extremity injuries, and have more serious overuse stress injuries. Adult recreational players tend to tolerate lower volumes, have more overuse and upper extremity injuries, and more conditions that are degenerative. Many tennis players also develop asymmetric musculoskeletal adaptations, which may increase risk of specific injury. Tennis-specific evaluations may identify these at-risk segments, help guide preventive strategies including technical errors, and assist in developing return-to-play recommendations. Other racket sports such as squash, badminton, and racquetball have less data available but report both acute and traumatic injuries less commonly seen in tennis.
High concentration agglomerate dynamics at high temperatures.
Heine, M C; Pratsinis, S E
2006-11-21
The dynamics of agglomerate aerosols are investigated at high solids concentrations that are typical in industrial scale manufacture of fine particles (precursor mole fraction larger than 10 mol %). In particular, formation and growth of fumed silica at such concentrations by chemical reaction, coagulation, and sintering is simulated at nonisothermal conditions and compared to limited experimental data and commercial product specifications. Using recent chemical kinetics for silica formation by SiCl4 hydrolysis and neglecting aerosol polydispersity, the evolution of the diameter of primary particles (specific surface area, SSA), hard- and soft-agglomerates, along with agglomerate effective volume fraction (volume occupied by agglomerate) is investigated. Classic Smoluchowski theory is fundamentally limited for description of soft-agglomerate Brownian coagulation at high solids concentrations. In fact, these high concentrations affect little the primary particle diameter (or SSA) but dominate the soft-agglomerate diameter, structure, and volume fraction, leading to gelation consistent with experimental data. This indicates that restructuring and fragmentation should affect product particle characteristics during high-temperature synthesis of nanostructured particles at high concentrations in aerosol flow reactors.
Choi, Hyungsuk; Choi, Woohyuk; Quan, Tran Minh; Hildebrand, David G C; Pfister, Hanspeter; Jeong, Won-Ki
2014-12-01
As the size of image data from microscopes and telescopes increases, the need for high-throughput processing and visualization of large volumetric data has become more pressing. At the same time, many-core processors and GPU accelerators are commonplace, making high-performance distributed heterogeneous computing systems affordable. However, effectively utilizing GPU clusters is difficult for novice programmers, and even experienced programmers often fail to fully leverage the computing power of new parallel architectures due to their steep learning curve and programming complexity. In this paper, we propose Vivaldi, a new domain-specific language for volume processing and visualization on distributed heterogeneous computing systems. Vivaldi's Python-like grammar and parallel processing abstractions provide flexible programming tools for non-experts to easily write high-performance parallel computing code. Vivaldi provides commonly used functions and numerical operators for customized visualization and high-throughput image processing applications. We demonstrate the performance and usability of Vivaldi on several examples ranging from volume rendering to image segmentation.
Protein-surface interactions on stimuli-responsive polymeric biomaterials.
Cross, Michael C; Toomey, Ryan G; Gallant, Nathan D
2016-03-04
Responsive surfaces: a review of the dependence of protein adsorption on the reversible volume phase transition in stimuli-responsive polymers. Specifically addressed are a widely studied subset: thermoresponsive polymers. Findings are also generalizable to other materials which undergo a similarly reversible volume phase transition. As of 2015, over 100,000 articles have been published on stimuli-responsive polymers and many more on protein-biomaterial interactions. Significantly, fewer than 100 of these have focused specifically on protein interactions with stimuli-responsive polymers. These report a clear trend of increased protein adsorption in the collapsed state compared to the swollen state. This control over protein interactions makes stimuli-responsive polymers highly useful in biomedical applications such as wound repair scaffolds, on-demand drug delivery, and antifouling surfaces. Outstanding questions are whether the protein adsorption is reversible with the volume phase transition and whether there is a time-dependence. A clear understanding of protein interactions with stimuli-responsive polymers will advance theoretical models, experimental results, and biomedical applications.
Mancebo, Camino M; Merino, Cristina; Martínez, Mario M; Gómez, Manuel
2015-10-01
Gluten-free bread production requires gluten-free flours or starches. Rice flour and maize starch are two of the most commonly used raw materials. Over recent years, gluten-free wheat starch is available on the market. The aim of this research was to optimize mixtures of rice flour, maize starch and wheat starch using an experimental mixture design. For this purpose, dough rheology and its fermentation behaviour were studied. Quality bread parameters such as specific volume, texture, cell structure, colour and acceptability were also analysed. Generally, starch incorporation reduced G* and increased the bread specific volume and cell density, but the breads obtained were paler than the rice flour breads. Comparing the starches, wheat starch breads had better overall acceptability and had a greater volume than maize-starch bread. The highest value for sensorial acceptability corresponded to the bread produced with a mixture of rice flour (59 g/100 g) and wheat starch (41 g/100 g).
Rigo, Vincent; Graas, Estelle; Rigo, Jacques
2012-07-01
Selected optimal respiratory cycles should allow calculation of respiratory mechanic parameters focusing on patient-ventilator interaction. New computer software automatically selecting optimal breaths and respiratory mechanics derived from those cycles are evaluated. Retrospective study. University level III neonatal intensive care unit. Ten mins synchronized intermittent mandatory ventilation and assist/control ventilation recordings from ten newborns. The ventilator provided respiratory mechanic data (ventilator respiratory cycles) every 10 secs. Pressure, flow, and volume waves and pressure-volume, pressure-flow, and volume-flow loops were reconstructed from continuous pressure-volume recordings. Visual assessment determined assisted leak-free optimal respiratory cycles (selected respiratory cycles). New software graded the quality of cycles (automated respiratory cycles). Respiratory mechanic values were derived from both sets of optimal cycles. We evaluated quality selection and compared mean values and their variability according to ventilatory mode and respiratory mechanic provenance. To assess discriminating power, all 45 "t" values obtained from interpatient comparisons were compared for each respiratory mechanic parameter. A total of 11,724 breaths are evaluated. Automated respiratory cycle/selected respiratory cycle selections agreement is high: 88% of maximal κ with linear weighting. Specificity and positive predictive values are 0.98 and 0.96, respectively. Averaged values are similar between automated respiratory cycle and ventilator respiratory cycle. C20/C alone is markedly decreased in automated respiratory cycle (1.27 ± 0.37 vs. 1.81 ± 0.67). Tidal volume apparent similarity disappears in assist/control: automated respiratory cycle tidal volume (4.8 ± 1.0 mL/kg) is significantly lower than for ventilator respiratory cycle (5.6 ± 1.8 mL/kg). Coefficients of variation decrease for all automated respiratory cycle parameters in all infants. "t" values from ventilator respiratory cycle data are two to three times higher than ventilator respiratory cycles. Automated selection is highly specific. Automated respiratory cycle reflects most the interaction of both ventilator and patient. Improving discriminating power of ventilator monitoring will likely help in assessing disease status and following trends. Averaged parameters derived from automated respiratory cycles are more precise and could be displayed by ventilators to improve real-time fine tuning of ventilator settings.
NASA Technical Reports Server (NTRS)
Keeley, J. T.
1976-01-01
The Labcraft Payload General Specification (LPGS) amplifies those general requirements in the Labcraft Program Specification (LPS) to ensure that all hardware, software, and STS elements will successfully function as an integrated system to accomplish the objectives of the first Labcraft mission. Contract End Item Specifications (CEIS) and Procurement Drawings (PDs) prepared and implemented for all deliverable hardware and software elements are discussed.
DOT National Transportation Integrated Search
2001-12-01
The current performance-related specifications (PRS) methodology has been under development by the Federal : Highway~Administration (FI-IWA) for several years and has now reached a level at which it can be implemented by : State highway agencies. PRS...
Side-Specific Reward Memories in Honeybees
ERIC Educational Resources Information Center
Gil, Mariana; Menzel, Randolf; De Marco, Rodrigo J.
2009-01-01
We report a hitherto unknown form of side-specific learning in honeybees. We trained bees individually by coupling gustatory and mechanical stimulation of each antenna with either increasing or decreasing volumes of sucrose solution offered to the animal's proboscis along successive learning trials. Next, we examined their proboscis extension…
Propulsion System Technology for Military Land Vehicles
1981-08-01
torques) to decrease specific weight and volume; and (3) hybrid transmissions using low-torque devices (electrical converters or traction drives) with a... VEICLE SPEC POMWE, bWtu FIGURE 1. Impact of vehicle specific power on weight and manufacturing cost of armored vehicles. 15 [ !00, LCV .30 *1
Familial and environmental influences on brain volumes in twins with schizophrenia.
Picchioni, Marco M; Rijsdijk, Fruhling; Toulopoulou, Timothea; Chaddock, Christopher; Cole, James H; Ettinger, Ulrich; Oses, Ana; Metcalfe, Hugo; Murray, Robin M; McGuire, Philip
2017-03-01
Reductions in whole brain and grey matter volumes are robust features of schizophrenia, yet their etiological influences are unclear. We investigated the association between the genetic and environmental risk for schizophrenia and brain volumes. Whole brain, grey matter and white matter volumes were established from structural MRIs from twins varying in their zygosity and concordance for schizophrenia. Hippocampal volumes were measured manually. We conducted between-group testing and full genetic modelling. We included 168 twins in our study. Whole brain, grey matter, white matter and right hippocampal volumes were smaller in twins with schizophrenia. Twin correlations were larger for whole brain, grey matter and white matter volumes in monozygotic than dizygotic twins and were significantly heritable, whereas hippocampal volume was the most environmentally sensitive. There was a significant phenotypic correlation between schizophrenia and reductions in all the brain volumes except for that of the left hippocampus. For whole brain, grey matter and the right hippocampus the etiological links with schizophrenia were principally associated with the shared familial environment. Lower birth weight and perinatal hypoxia were both associated with lower whole brain volume and with lower white matter and grey matter volumes, respectively. Scan data were collected across 2 sites, and some groups were modest in size. Whole brain, grey matter and right hippocampal volume reductions are linked to schizophrenia through correlated familial risk (i.e., the shared familial environment). The degree of influence of etiological factors varies between brain structures, leading to the possibility of a neuroanatomically specific etiological imprint.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Banse, K.
1982-01-01
A review of growth rates of diatoms and dinoflagellates in light-saturated, nutrient-replete cultures at 20/sup 0/C confirms weak dependence on cell volume or mass. These maximal (intrinsic) rates are not linearly related to surface area or surface-to-volume ratio of the cells. The growth of most diatoms is materially faster than that of dinoflagellates; other algae fall in between or below the dinoflagellates. Small ciliates have appreciably higher intrinsic growth rates than algae of the same cell volume. The average food consumption per ciliate in the marine pelagic realm is inferred to be very low, so that the realized specific growthmore » rates are much smaller than the intrinsic potentials. Also, a previously postulated refuge from predation, afforded by small size, is extended down to about 10-..mu..m/sup 3/ cell volume.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1982-01-01
Report XI, Technical Audit, is a compendium of research material used during the Initial Effort in making engineering comparisons and decisions. Volumes 4 and 5 of Report XI present those studies which provide a Critical Review of the Design Basis. The Critical Review Report, prepared by Intercontinental Econergy Associates, Inc., summarizes findings from an extensive review of the data base for the H-Coal process design. Volume 4 presents this review and assessment, and includes supporting material; specifically, Design Data Tabulation (Appendix A), Process Flow Sheets (Appendix B), and References (Appendix C). Volume 5 is a continuation of the references ofmore » Appendix C. Studies of a proprietary nature are noted and referenced, but are not included in these volumes. They are included in the Limited Access versions of these reports and may be reviewed by properly cleared personnel in the offices of Ashland Synthetic Fuels, Inc.« less
Imai, Takashi; Ohyama, Shusaku; Kovalenko, Andriy; Hirata, Fumio
2007-01-01
The partial molar volume (PMV) change associated with the pressure-induced structural transition of ubiquitin is analyzed by the three-dimensional reference interaction site model (3D-RISM) theory of molecular solvation. The theory predicts that the PMV decreases upon the structural transition, which is consistent with the experimental observation. The volume decomposition analysis demonstrates that the PMV reduction is primarily caused by the decrease in the volume of structural voids in the protein, which is partially canceled by the volume expansion due to the hydration effects. It is found from further analysis that the PMV reduction is ascribed substantially to the penetration of water molecules into a specific part of the protein. Based on the thermodynamic relation, this result implies that the water penetration causes the pressure-induced structural transition. It supports the water penetration model of pressure denaturation of proteins proposed earlier. PMID:17660257
Changes in apparent molar water volume and DKP solubility yield insights on the Hofmeister effect.
Payumo, Alexander Y; Huijon, R Michael; Mansfield, Deauna D; Belk, Laurel M; Bui, Annie K; Knight, Anne E; Eggers, Daryl K
2011-12-15
This study examines the properties of a 4 × 2 matrix of aqueous cations and anions at concentrations up to 8.0 M. The apparent molar water volume, as calculated by subtracting the mass and volume of the ions from the corresponding solution density, was found to exceed the molar volume of ice in many concentrated electrolyte solutions, underscoring the nonideal behavior of these systems. The solvent properties of water were also analyzed by measuring the solubility of diketopiperazine (DKP) in 2.000 M salt solutions prepared from the same ion combinations. Solution rankings for DKP solubility were found to parallel the Hofmeister series for both cations and anions, whereas molar water volume concurred with the cation series only. The results are discussed within the framework of a desolvation energy model that attributes solute-specific changes in equilibria to solute-dependent changes in the free energy of bulk water.
Imai, Takashi; Ohyama, Shusaku; Kovalenko, Andriy; Hirata, Fumio
2007-09-01
The partial molar volume (PMV) change associated with the pressure-induced structural transition of ubiquitin is analyzed by the three-dimensional reference interaction site model (3D-RISM) theory of molecular solvation. The theory predicts that the PMV decreases upon the structural transition, which is consistent with the experimental observation. The volume decomposition analysis demonstrates that the PMV reduction is primarily caused by the decrease in the volume of structural voids in the protein, which is partially canceled by the volume expansion due to the hydration effects. It is found from further analysis that the PMV reduction is ascribed substantially to the penetration of water molecules into a specific part of the protein. Based on the thermodynamic relation, this result implies that the water penetration causes the pressure-induced structural transition. It supports the water penetration model of pressure denaturation of proteins proposed earlier.
Changes in Apparent Molar Water Volume and DKP Solubility Yield Insights on the Hofmeister Effect
Payumo, Alexander Y.; Huijon, R. Michael; Mansfield, Deauna D.; Belk, Laurel M.; Bui, Annie K.; Knight, Anne E.; Eggers, Daryl K.
2011-01-01
This study examines the properties of a 4 × 2 matrix of aqueous cations and anions at concentrations up to 8.0 M. The apparent molar water volume, as calculated by subtracting the mass and volume of the ions from the corresponding solution density, was found to exceed the molar volume of ice in many concentrated electrolyte solutions, underscoring the non-ideal behavior of these systems. The solvent properties of water were also analyzed by measuring the solubility of diketopiperazine (DKP) in 2.000 M salt solutions prepared from the same ion combinations. Solution rankings for DKP solubility were found to parallel the Hofmeister series for both cations and anions, whereas molar water volume concurred with the cation series only. The results are discussed within the framework of a desolvation energy model that attributes solute-specific changes in equilibria to solute-dependent changes in the free energy of bulk water. PMID:22029390
NASA Astrophysics Data System (ADS)
Duarte Queirós, S. M.
2005-08-01
This letter reports on a stochastic dynamical scenario whose associated stationary probability density function is exactly a generalised form, with a power law instead of exponencial decay, of the ubiquitous Gamma distribution. This generalisation, also known as F-distribution, was empirically proposed for the first time to adjust for high-frequency stock traded volume distributions in financial markets and verified in experiments with granular material. The dynamical assumption presented herein is based on local temporal fluctuations of the average value of the observable under study. This proposal is related to superstatistics and thus to the current nonextensive statistical mechanics framework. For the specific case of stock traded volume, we connect the local fluctuations in the mean stock traded volume with the typical herding behaviour presented by financial traders. Last of all, NASDAQ 1 and 2 minute stock traded volume sequences and probability density functions are numerically reproduced.
Relativistic, model-independent, multichannel 2 → 2 transition amplitudes in a finite volume
Briceno, Raul A.; Hansen, Maxwell T.
2016-07-13
We derive formalism for determining 2 + J → 2 infinite-volume transition amplitudes from finite-volume matrix elements. Specifically, we present a relativistic, model-independent relation between finite-volume matrix elements of external currents and the physically observable infinite-volume matrix elements involving two-particle asymptotic states. The result presented holds for states composed of two scalar bosons. These can be identical or non-identical and, in the latter case, can be either degenerate or non-degenerate. We further accommodate any number of strongly-coupled two-scalar channels. This formalism will, for example, allow future lattice QCD calculations of themore » $$\\rho$$-meson form factor, in which the unstable nature of the $$\\rho$$ is rigorously accommodated. In conclusion, we also discuss how this work will impact future extractions of nuclear parity and hadronic long-range matrix elements from lattice QCD.« less
PRESSURE-VOLUME RELATIONSHIP OF THE FUNDULUS EGG IN SEA WATER AND IN SUCROSE
Kao, C. Y.
1956-01-01
Upon activation, an internal hydrostatic pressure develops within the Fundulus egg, and compresses the egg proper to a reduced volume. When the perivitelline pressure is abolished by a highly hypertonic sucrose solution, the egg volume increases. As sucrose penetrates the chorion, the volume again decreases. The relation between P and V in these conditions is inverse, and approximates a rectangular hyperbola. The limiting factor causing most of the deviation is shown to be the incompressible fraction. It is concluded that the volume of the egg proper is controlled by the perivitelline pressure, and that the effect of hypertonic sucrose solution is exerted by lowering the pressure and thereby increasing membrane permeability non-specifically. It is also shown that some permanent alterations occur within the plasma membrane during activation that reduce the permeance, and thereby, increase the incompressible fraction. PMID:13357739
Nagle, J F; Wiener, M C
1989-01-01
Three relations are derived that connect low angle diffraction/scattering results obtained from lipid bilayers to other structural quantities of interest. The first relates the area along the surface of the bilayer, the measured specific volume, and the zeroth order structure factor, F(0). The second relates the size of the trough in the center of the electron density profile, the volume of the terminal methyl groups, and the volume of the methylene groups in the fatty acid chains. The third relates the size of the headgroup electron density peak, the volume of the headgroup, and the volumes of water and hydrocarbon in the headgroup region. These relations, which are easily modified for neutron diffraction, are useful for obtaining structural quantities from electron density profiles obtained by fitting model profiles to measured low angle x-ray intensities. PMID:2713444
The Human as a System - Monitoring Spacecraft Net Habitable Volume throughout the Design Lifecycle
NASA Technical Reports Server (NTRS)
Szabo, Richard; Kallay, Anna; Twyford, Evan; Maida, Jim
2007-01-01
Spacecraft design has historically allocated specific volume and mass "not to exceed" requirements upon individual systems and their accompanying hardware (e.g., life support, avionics) early in their conceptual design in an effort to align the spacecraft with propulsion capabilities. If the spacecraft is too heavy or too wide for the launch stack - it does not get off the ground. This approach has predictably ended with the crew being allocated whatever open, pressurized volume remains. With the recent inauguration of a new human-rated spacecraft - NASA human factors personnel have found themselves in the unique position to redefine the human as a system from the very foundation of design. They seek to develop and monitor a "not to fall below" requirement for crew net habitable volume (NHV) - balanced against the "not to exceed" system volume requirements, with the spacecraft fitting the crew versus the crew having to fit inside the spacecraft.
Sey, Michael Sai Lai; Gregor, Jamie; Chande, Nilesh; Ponich, Terry; Bhaduri, Mousumi; Lum, Andrea; Zaleski, Witek; Yan, Brian
2013-08-01
Transcutaneous bowel sonography is a nonionizing imaging modality used in inflammatory bowel disease. Although available in Europe, its uptake in North America has been limited. Since the accuracy of bowel sonography is highly operator dependent, low-volume centers in North America may not achieve the same diagnostic accuracy reported in the European literature. Our objective was to determine the diagnostic accuracy of bowel sonography in a nonexpert low-volume center. All cases of bowel sonography at a single tertiary care center during an 18-month period were reviewed. Bowel sonography was compared with reference standards, including small-bowel follow-through, computed tomography, magnetic resonance imaging, colonoscopy, and surgical findings. A total of 103 cases were included for analysis during the study period. The final diagnoses included Crohn disease (72), ulcerative colitis (8), hemolytic uremic syndrome (1), and normal (22). The sensitivity and specificity of bowel sonography for intestinal wall inflammation were 87.8% and 92.6%, respectively. In the subset of patients who had complications of Crohn disease, the sensitivity and specificity were 50% and 100% for fistulas and 14% and 100% for strictures. One patient had an abscess, which was detected by bowel sonography. Abnormal bowel sonographic findings contributed to the escalation of treatment in 55% of cases. Bowel sonography for inflammatory bowel disease can be performed in low-volume centers and provides diagnostic accuracy for luminal disease comparable with published data, although it is less sensitive for complications of Crohn disease.
NASA Technical Reports Server (NTRS)
1973-01-01
The design specifications for the programs and modules within the NASA Aerospace Safety Information System (NASIS) are presented. The purpose of the design specifications is to standardize the preparation of the specifications and to guide the program design. Each major functional module within the system is a separate entity for documentation purposes. The design specifications contain a description of, and specifications for, all detail processing which occurs in the module. Sub-models, reference tables, and data sets which are common to several modules are documented separately.
Performance analysis of radiation cooled dc transmission lines for high power space systems
NASA Technical Reports Server (NTRS)
Schwarze, G. E.
1985-01-01
As space power levels increase to meet mission objectives and also as the transmission distance between power source and load increases, the mass, volume, power loss, and operating voltage and temperature become important system design considerations. This analysis develops the dependence of the specific mass and percent power loss on hte power and voltage levels, transmission distance, operating temperature and conductor material properties. Only radiation cooling is considered since the transmission line is assumed to operate in a space environment. The results show that the limiting conditions for achieving low specific mass, percent power loss, and volume for a space-type dc transmission line are the permissible transmission voltage and operating temperature. Other means to achieve low specific mass include the judicious choice of conductor materials. The results of this analysis should be immediately applicable to power system trade-off studies including comparisons with ac transmission systems.
Investigating relationships between left atrial volume, symmetry, and sphericity
NASA Astrophysics Data System (ADS)
Menon, Prahlad G.; Nedios, Sotiris; Hindricks, Gerhard; Bollmann, Andreas
2016-03-01
Catheter ablation is a safe and effective therapy for drug-refractory patients symptomatic of atrial fibrillation (AF), with up to 80% of patients experiencing long-term arrhythmia-free survival. However, up to 20-40% of patients require more than one procedure in order to become arrhythmia-free. Therefore, appropriate patient selection is paramount to the effective implementation and long-term success of ablation therapy for patients with atrial fibrillation (AF). In this study, as a precursor to evaluating clinical significance of specific LA shape metrics as pre-procedural predictors of AF recurrence following ablative pulmonary vein isolation therapy, we report on a computational geometric analysis in a pilot cohort evaluating relationships between various patient-specific metrics of LA shape which might have such predictive value. This study specifically is focused on establishing the relationship between LA volume and sphericity, using a novel methodology for computing atrial sphericity based on regional shape.
Busch, Martin H J; Vollmann, Wolfgang; Schnorr, Jörg; Grönemeyer, Dietrich H W
2005-04-08
Active Magnetic Resonance Imaging implants are constructed as resonators tuned to the Larmor frequency of a magnetic resonance system with a specific field strength. The resonating circuit may be embedded into or added to the normal metallic implant structure. The resonators build inductively coupled wireless transmit and receive coils and can amplify the signal, normally decreased by eddy currents, inside metallic structures without affecting the rest of the spin ensemble. During magnetic resonance imaging the resonators generate heat, which is additional to the usual one described by the specific absorption rate. This induces temperature increases of the tissue around the circuit paths and inside the lumen of an active implant and may negatively influence patient safety. This investigation provides an overview of the supplementary power absorbed by active implants with a cylindrical geometry, corresponding to vessel implants such as stents, stent grafts or vena cava filters. The knowledge of the overall absorbed power is used in a finite volume analysis to estimate temperature maps around different implant structures inside homogeneous tissue under worst-case assumptions. The "worst-case scenario" assumes thermal heat conduction without blood perfusion inside the tissue around the implant and mostly without any cooling due to blood flow inside vessels. The additional power loss of a resonator is proportional to the volume and the quality factor, as well as the field strength of the MRI system and the specific absorption rate of the applied sequence. For properly working devices the finite volume analysis showed only tolerable heating during MRI investigations in most cases. Only resonators transforming a few hundred mW into heat may reach temperature increases over 5 K. This requires resonators with volumes of several ten cubic centimeters, short inductor circuit paths with only a few 10 cm and a quality factor above ten. Using MR sequences, for which the MRI system manufacturer declares the highest specific absorption rate of 4 W/kg, vascular implants with a realistic construction, size and quality factor do not show temperature increases over a critical value of 5 K. The results show dangerous heating for the assumed "worst-case scenario" only for constructions not acceptable for vascular implants. Realistic devices are safe with respect to temperature increases. However, this investigation discusses only properly working devices. Ruptures or partial ruptures of the wires carrying the electric current of the resonance circuits or other defects can set up a power source inside an extremely small volume. The temperature maps around such possible "hot spots" should be analyzed in an additional investigation.