Sample records for specimen test techniques

  1. Tensile-Creep Test Specimen Preparation Practices of Surface Support Liners

    NASA Astrophysics Data System (ADS)

    Guner, Dogukan; Ozturk, Hasan

    2017-12-01

    Ground support has always been considered as a challenging issue in all underground operations. Many forms of support systems and supporting techniques are available in the mining/tunnelling industry. In the last two decades, a new polymer based material, Thin Spray-on Liner (TSL), has attained a place in the market as an alternative to the current areal ground support systems. Although TSL provides numerous merits and has different application purposes, the knowledge on mechanical properties and performance of this material is still limited. In laboratory studies, since tensile rupture is the most commonly observed failure mechanism in field applications, researchers have generally studied the tensile testing of TSLs with modification of American Society for Testing and Materials (ASTM) D-638 standards. For tensile creep testing, specimen preparation process also follows the ASTM standards. Two different specimen dimension types (Type I, Type IV) are widely preferred in TSL tensile testing that conform to the related standards. Moreover, molding and die cutting are commonly used specimen preparation techniques. In literature, there is a great variability of test results due to the difference in specimen preparation techniques and practices. In this study, a ductile TSL product was tested in order to investigate the effect of both specimen preparation techniques and specimen dimensions under 7-day curing time. As a result, ultimate tensile strength, tensile yield strength, tensile modulus, and elongation at break values were obtained for 4 different test series. It is concluded that Type IV specimens have higher strength values compared to Type I specimens and moulded specimens have lower results than that of prepared by using die cutter. Moreover, specimens prepared by molding techniques have scattered test results. Type IV specimens prepared by die cutter technique are suggested for preparation of tensile test and Type I specimens prepared by die cutter technique should be preferred for tensile creep tests.

  2. Wide Panel Testing Technique for Evaluating Repair Weld Strengths

    NASA Technical Reports Server (NTRS)

    Rogers, Patrick R.; Bynum, Julian E.; Shah, Sandeep R.

    1998-01-01

    This paper describes a new tensile testing technique for evaluating the overall effect of a repair weld on the strength of a welded joint. Previously, repair weld strengths have been evaluated using one-inch width tensile specimens, but this technique does not capture all of the effects that result from a repair. The new technique involves testing of "wide panel" tensile specimens which contain the full length of a repair weld within a longer initial weld, allowing the specimen to capture the combined effects of residual stresses, local strength degradation, and load redistribution around a repair. The development of strains in the repair area of standard aluminum alloy specimens and new high-performance aluminum-lithium alloy specimens was observed and evaluated using photoelastic material. The results of this evaluation show an increased sensitivity to repair welding residual stresses in the aluminum-lithium alloy specimens.

  3. Contact thermal shock test of ceramics

    NASA Technical Reports Server (NTRS)

    Rogers, W. P.; Emery, A. F.

    1992-01-01

    A novel quantitative thermal shock test of ceramics is described. The technique employs contact between a metal-cooling rod and hot disk-shaped specimen. In contrast with traditional techniques, the well-defined thermal boundary condition allows for accurate analyses of heat transfer, stress, and fracture. Uniform equibiaxial tensile stresses are induced in the center of the test specimen. Transient specimen temperature and acoustic emission are monitored continuously during the thermal stress cycle. The technique is demonstrated with soda-lime glass specimens. Experimental results are compared with theoretical predictions based on a finite-element method thermal stress analysis combined with a statistical model of fracture. Material strength parameters are determined using concentric ring flexure tests. Good agreement is found between experimental results and theoretical predictions of failure probability as a function of time and initial specimen temperature.

  4. Evaluation of Stress Corrosion Cracking Susceptibility Using Fracture Mechanics Techniques, Part 1. [environmental tests of aluminum alloys, stainless steels, and titanium alloys

    NASA Technical Reports Server (NTRS)

    Sprowls, D. O.; Shumaker, M. B.; Walsh, J. D.; Coursen, J. W.

    1973-01-01

    Stress corrosion cracking (SSC) tests were performed on 13 aluminum alloys, 13 precipitation hardening stainless steels, and two titanium 6Al-4V alloy forgings to compare fracture mechanics techniques with the conventional smooth specimen procedures. Commercially fabricated plate and rolled or forged bars 2 to 2.5-in. thick were tested. Exposures were conducted outdoors in a seacoast atmosphere and in an inland industrial atmosphere to relate the accelerated tests with service type environments. With the fracture mechanics technique tests were made chiefly on bolt loaded fatigue precracked compact tension specimens of the type used for plane-strain fracture toughness tests. Additional tests of the aluminum alloy were performed on ring loaded compact tension specimens and on bolt loaded double cantilever beams. For the smooth specimen procedure 0.125-in. dia. tensile specimens were loaded axially in constant deformation type frames. For both aluminum and steel alloys comparative SCC growth rates obtained from tests of precracked specimens provide an additional useful characterization of the SCC behavior of an alloy.

  5. Fracture toughness testing on ferritic alloys using the electropotential technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, F.H.; Wire, G.L.

    1981-06-11

    Fracture toughness measurements as done conventionally require large specimens (5 x 5 x 2.5 cm) which would be prohibitively expensive to irradiate over the fluence and temperature ranges required for first wall design. To overcome this difficulty a single specimen technique for J intergral fracture toughness measurements on miniature specimens (1.6 cm OD x 0.25 cm thick) was developed. Comparisons with specimens three times as thick show that the derived J/sub 1c/ is constant, validating the specimen for first wall applications. The electropotential technique was used to obtain continuous crack extension measurements, allowing a ductile fracture resistence curve to bemore » constructed from a single specimen. The irradiation test volume required for fracture toughness measurements using both miniature specimens and single specimen J measurements was reduced a factor of 320, making it possible to perform a systematic exploration of irradiation temperature and dose variables as required for qualification of HT-9 and 9Cr-1Mo base metal and welds for first wall application. Fracture toughness test results for HT-9 and 9Cr-1Mo from 25 to 539/sup 0/C are presented to illustrate the single specimen technique.« less

  6. In vitro evaluation of marginal adaptation in five ceramic restoration fabricating techniques.

    PubMed

    Ural, Cağri; Burgaz, Yavuz; Saraç, Duygu

    2010-01-01

    To compare in vitro the marginal adaptation of crowns manufactured using ceramic restoration fabricating techniques. Fifty standardized master steel dies simulating molars were produced and divided into five groups, each containing 10 specimens. Test specimens were fabricated with CAD/CAM, heat-press, glass-infiltration, and conventional lost-wax techniques according to manufacturer instructions. Marginal adaptation of the test specimens was measured vertically before and after cementation using SEM. Data were statistically analyzed by one-way ANOVA with Tukey HSD tests (a = .05). Marginal adaptation of ceramic crowns was affected by fabrication technique and cementation process (P < .001). The lowest marginal opening values were obtained with Cerec-3 crowns before and after cementation (P < .001). The highest marginal discrepancy values were obtained with PFM crowns before and after cementation. Marginal adaptation values obtained in the compared systems were within clinically acceptable limits. Cementation causes a significant increase in the vertical marginal discrepancies of the test specimens.

  7. Comparison of normal and phase stepping shearographic NDE

    NASA Astrophysics Data System (ADS)

    Andhee, A.; Gryzagoridis, J.; Findeis, D.

    2005-05-01

    The paper presents results of non-destructive testing of composite main rotor helicopter blade calibration specimens using the laser based optical NDE technique known as Shearography. The tests were performed initially using the already well established near real-time non-destructive technique of Shearography, with the specimens perturbed during testing for a few seconds using the hot air from a domestic hair dryer. Subsequent to modification of the shearing device utilized in the shearographic setup, phase stepping of one of the sheared images to be captured by the CCD camera was enabled and identical tests were performed on the composite main rotor helicopter blade specimens. Considerable enhancement of the images manifesting or depicting the defects on the specimens is noted suggesting that phase stepping is a desirable enhancement technique to the traditional Shearographic setup.

  8. Noncontact Acousto-Ultrasonic Testing With Laser Beams

    NASA Technical Reports Server (NTRS)

    Huber, Robert D.; Green, Robert E., Jr.

    1994-01-01

    Laser beams used to excite and detect acoustic waves in specimens. Laser/acousto-ultrasonic technique entails no mechanical contact between specimens and testing apparatus. Apparatus located at relatively large distances (meters) from specimens, making it possible to test specimens too hot for contact measurements or located in inaccessible places, vacuums, or hostile environments.

  9. New test structures and techniques for measurement of mechanical properties of MEMS materials

    NASA Astrophysics Data System (ADS)

    Sharpe, William N., Jr.; Yuan, Bin; Vaidyanathan, Ranji; Edwards, Richard L.

    1996-09-01

    This paper presents techniques and procedures for addressing the three major problems of mechanical testing of the thin films used in surface micromachined microelectromechanical systems--specimen handling, friction, and strain measurement. The polysilicon tensile specimens are fabricated with two supporting side strips on silicon wafers at the Microelectronic Center of North Carolina. The tensile specimen is released by etching away the wafer, and the two support strips are cut after the specimen is glued in the test machine. Friction is reduced by a linear air bearing in the load train, and strain is measured with a noncontacting technique based on laser interferometry between two gold lines on the tensile specimen. The Young's modulus of polysilicon is 170 +/- 7 GPa and the strength is 1.21 +/- 0.16 GPa from a series of 29 tests. preliminary measurements have been made of Poisson's ratio and the fatigue behavior, and an attempt is underway to measure the fracture toughness.

  10. Diagnosis of AIDS-Related Intestinal Parasites

    DTIC Science & Technology

    1990-06-20

    previously in ELISA tests to detect antigens of either Giardia lamblia or Entamoeba histolytica in human fecal specimens (67,68), the mean optical...techniques. Eight other intestinal parasites were idtritified Giardia lamblia (67 specimens), Endoimax nana (38 specimens), Entamoeba coli (34 specimens...tests to detect antigens of Entamoeba histolytica or Giardia lamblia in fecal specimens are now truly well-established and have been developed by at

  11. Tensile strength of various nylon PA6 specimen modes

    NASA Astrophysics Data System (ADS)

    Raz, Karel; Zahalka, Martin

    2017-05-01

    This article explores the influence of production technique on the strength of nylon parts. Identical specimens were manufactured by various techniques. The material of specimens was nylon PA6. 3D printing and injection molding were used, with various orientations of printed layers, and various orientations of specimens in the working space of the 3D printer. The variants are described in detail. A special mold was used for the injection molding process in order to make specimens with and without a weld line. The effect of this weld line was evaluated. All specimens were tested using the standard tensile test configuration. The strength was compared. It was found that the same plastic material has very different mechanical properties depending on the production process.

  12. Single-Specimen Technique to Establish the J-Resistance of Linear Viscoelastic Solids with Constant Poisson's Ratio

    NASA Technical Reports Server (NTRS)

    Gutierrez-Lemini, Danton; McCool, Alex (Technical Monitor)

    2001-01-01

    A method is developed to establish the J-resistance function for an isotropic linear viscoelastic solid of constant Poisson's ratio using the single-specimen technique with constant-rate test data. The method is based on the fact that, for a test specimen of fixed crack size under constant rate, the initiation J-integral may be established from the crack size itself, the actual external load and load-point displacement at growth initiation, and the relaxation modulus of the viscoelastic solid, without knowledge of the complete test record. Since crack size alone, of the required data, would be unknown at each point of the load-vs-load-point displacement curve of a single-specimen test, an expression is derived to estimate it. With it, the physical J-integral at each point of the test record may be established. Because of its basis on single-specimen testing, not only does the method not require the use of multiple specimens with differing initial crack sizes, but avoids the need for tracking crack growth as well.

  13. High temperature tensile testing of ceramic composites

    NASA Technical Reports Server (NTRS)

    Gyekenyesi, John Z.; Hemann, John H.

    1988-01-01

    The various components of a high temperature tensile testing system are evaluated. The objective is the high temperature tensile testing of SiC fiber reinforced reaction bonded Si3N4 specimens at test temperatures up to 1650 C (3000 F). Testing is to be conducted in inert gases and air. Gripping fixtures, specimen configurations, furnaces, optical strain measuring systems, and temperature measurement techniques are reviewed. Advantages and disadvantages of the various techniques are also noted.

  14. Measurement of intergranular attack in stainless steel using ultrasonic energy

    DOEpatents

    Mott, Gerry; Attaar, Mustan; Rishel, Rick D.

    1989-08-08

    Ultrasonic test methods are used to measure the depth of intergranular attack (IGA) in a stainless steel specimen. The ultrasonic test methods include a pitch-catch surface wave technique and a through-wall pulse-echo technique. When used in combination, these techniques can establish the extent of IGA on both the front and back surfaces of a stainless steel specimen from measurements made on only one surface.

  15. 16 CFR 1209.5 - Test procedures for corrosiveness.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., combed, or otherwise mixed to reasonably assure homogeneity in the cellulose insulation test specimens... Evaluating Corrosion Test Specimens,” published by American Society for Testing and Materials, 1916 Race... acid (plus water). To avoid injury in this and subsequent techniques when mixing acid and water...

  16. Investigation of Dynamic Crack Coalescence Using a Gypsum-Like 3D Printing Material

    NASA Astrophysics Data System (ADS)

    Jiang, Chao; Zhao, Gao-Feng; Zhu, Jianbo; Zhao, Yi-Xin; Shen, Luming

    2016-10-01

    Dynamic crack coalescence attracts great attention in rock mechanics. However, specimen preparation in experimental study is a time-consuming and difficult procedure. In this work, a gypsum-like material by powder bed and inkjet 3D printing technique was applied to produce specimens with preset cracks for split Hopkinson pressure bar (SHPB) test. From micro X-ray CT test, it was found that the 3D printing technique could successfully prepare specimens that contain preset cracks with width of 0.2 mm. Basic mechanical properties of the 3D printing material, i.e., the elastic modulus, the Poisson's ratio, the density, the compressive strength, the indirect tensile strength, and the fracture toughness, were obtained and reported. Unlike 3D printed specimens using polylactic acid, these gypsum-like specimens can produce failure patterns much closer to those observed in classical rock mechanical tests. Finally, the dynamic crack coalescence of the 3D printed specimens with preset cracks were captured using a high-speed camera during SHPB tests. Failure patterns of these 3D printed specimens are similar to the specimens made by Portland cement concrete. Our results indicate that sample preparation by 3D printing is highly competitive due to its quickness in prototyping, precision and flexibility on the geometry, and high material homogeneity.

  17. The Use of Doublers in Delamination Toughness Testing

    NASA Technical Reports Server (NTRS)

    Reeder, James R.; Demarco, Kevin; Whitley, Karen S.

    2002-01-01

    In this paper, the data reduction equations for common delamination toughness tests are rederived for use with specimens which have bonded doublers. The common toughness tests considered here are the double cantilever beam (DCB) for mode I toughness; the end notch flexure (3ENF) and 4 point ENF (4ENF) for mode II toughness; and the mixed mode bending (MMB) test for testing under combined mode I and mode II loading. Because the addition of the doublers changes the bending stiffness of the specimens, these data reduction equations may need to be corrected. Doublers were added to the delamination test specimens to solve a premature failure problem. Delamination toughness is normally tested using a beam with an imbedded insert so that one end of the specimen is split into two arms. If the specimen is too thin, or if the toughness of the material is too high, an arm of the specimen may fail in bending before the delamination grows. When this occurs, the toughness of the material cannot be determined. To delay the bending failure so that delamination growth occurs, doubler plates were bonded to both top and bottom surfaces of the specimen. A doubler parameter, beta, which describes how much the use of doubler plates changed the ratio of full thickness to delaminated bending stiffnesses, was defined. When changes to the data reduction equations were required, the changes were minor when written in terms of the beta parameter. The doubler plate technique was demonstrated by measuring the mixed-mode fracture toughness of a carbon-carbon composite using test specimens which would otherwise have failed before delamination growth occurred. The doubler plate technique may solve several problems that can be encountered when testing delamination fracture toughness.

  18. Influence of Water Content on Mechanical Properties of Rock in Both Saturation and Drying Processes

    NASA Astrophysics Data System (ADS)

    Zhou, Zilong; Cai, Xin; Cao, Wenzhuo; Li, Xibing; Xiong, Cheng

    2016-08-01

    Water content has a pronounced influence on the properties of rock materials, which is responsible for many rock engineering hazards, such as landslides and karst collapse. Meanwhile, water injection is also used for the prevention of some engineering disasters like rock-bursts. To comprehensively investigate the effect of water content on mechanical properties of rocks, laboratory tests were carried out on sandstone specimens with different water contents in both saturation and drying processes. The Nuclear Magnetic Resonance technique was applied to study the water distribution in specimens with variation of water contents. The servo-controlled rock mechanics testing machine and Split Hopkinson Pressure Bar technique were used to conduct both compressive and tensile tests on sandstone specimens with different water contents. From the laboratory tests, reductions of the compressive and tensile strength of sandstone under static and dynamic states in different saturation processes were observed. In the drying process, all of the saturated specimens could basically regain their mechanical properties and recover its strength as in the dry state. However, for partially saturated specimens in the saturation and drying processes, the tensile strength of specimens with the same water content was different, which could be related to different water distributions in specimens.

  19. Thick Concrete Specimen Construction, Testing, and Preliminary Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clayton, Dwight A.; Hoegh, Kyle; Khazanovich, Lev

    The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years. Since many important safety structures in an NPP are constructed of concrete, inspection techniques must be developed and tested to evaluate the internal condition. In-service containment structures generally do not allow for the destructive measures necessary to validate the accuracy of these inspection techniques. This creates a need for comparative testing of the variousmore » nondestructive evaluation (NDE) measurement techniques on concrete specimens with known material properties, voids, internal microstructure flaws, and reinforcement locations. A preliminary report detailed some of the challenges associated with thick reinforced concrete sections and prioritized conceptual designs of specimens that could be fabricated to represent NPP concrete structures for using in NDE evaluation comparisons. This led to the construction of the concrete specimen presented in this report, which has sufficient reinforcement density and cross-sectional size to represent an NPP containment wall. Details on how a suitably thick concrete specimen was constructed are presented, including the construction materials, final nominal design schematic, as well as formwork and rigging required to safely meet the desired dimensions of the concrete structure. The report also details the type and methods of forming the concrete specimen as well as information on how the rebar and simulated defects were embedded. Details on how the resulting specimen was transported, safely anchored, and marked to allow access for systematic comparative NDE testing of defects in a representative NPP containment wall concrete specimen are also given. Data collection using the MIRA Ultrasonic NDE equipment and initial results are also presented along with a discussion of the preliminary findings. Comparative NDE of various defects in reinforced concrete specimens is a key component in identifying the most promising techniques and directing the research and development efforts needed to characterize concrete degradation in commercial NPPs. This requires access to the specimens for data collection using state-of-the-art technology. The construction of the specimen detailed in this report allows for an evaluation of how different NDE techniques may interact with the size and complexities of NPP concrete structures. These factors were taken into account when determining specimen size and features to ensure a realistic design. The lateral dimensions of the specimen were also chosen to mitigate unrealistic boundary effects that would not affect the results of field NPP concrete testing. Preliminary results show that, while the current methods are able to identify some of the deeper defects, improvements in data processing or hardware are necessary to be able to achieve the precision and reliability achieved in evaluating thinner and less heavily reinforced concrete structures.« less

  20. Flexural strength and reliability of monolithic and trilayer ceramic structures obtained by the CAD-on technique.

    PubMed

    Basso, G R; Moraes, R R; Borba, M; Griggs, J A; Della Bona, A

    2015-12-01

    To evaluate the flexural strength, Weibull modulus, fracture toughness, and failure behavior of ceramic structures obtained by the CAD-on technique, testing the null hypothesis that trilayer structures show similar properties to monolithic structures. Bar-shaped (1.8mm×4mm×16mm) monolithic specimens of zirconia (IPS e.max ZirCAD - Ivoclar Vivadent) and trilayer specimens of zirconia/fusion ceramic/lithium dissilicate (IPS e.max ZirCAD/IPS e.max CAD Crystall./Connect/IPS e.max CAD, Ivoclar Vivadent) were fabricated (n=30). Specimens were tested in flexure in 37°C deionized water using a universal testing machine at a crosshead speed of 0.5mm/min. Failure loads were recorded, and the flexural strength values were calculated. Fractography principles were used to examine the fracture surfaces under optical and scanning electron microscopy. Data were statistically analyzed using Student's t-test and Weibull statistics (α=0.05). Monolithic and trilayer specimens showed similar mean flexural strengths, characteristic strengths, and Weibull moduli. Trilayer structures showed greater mean critical flaw and fracture toughness values than monolithic specimens (p<0.001). Most critical flaws in the trilayer groups were located on the Y-TZP surface subjected to tension and propagated catastrophically. Trilayer structures showed no flaw deflection at the interface. Considering the CAD-on technique, the trilayer structures showed greater fracture toughness than the monolithic zirconia specimens. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  1. Characterization of Mechanical Properties of Nuclear Graphite Using Subsize Specimens and Reusing Tested Specimens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ji Hyun, Yoon; Byun, Thak Sang; Strizak, Joe P

    2011-01-01

    The mechanical properties of NBG-18 nuclear grade graphite have been characterized using small specimen test techniques and statistical treatment on the test results. New fracture strength and toughness test techniques were developed to use subsize cylindrical specimens with glued heads and to reuse their broken halves. Three sets of subsize cylindrical specimens with the different diameters of 4 mm, 8 mm, and 12 mm were tested to obtain tensile fracture strength. The longer piece of the broken halves was cracked from side surfaces and tested under three-point bend loading to obtain fracture toughness. Both the strength and fracture toughness datamore » were analyzed using Weibull distribution models focusing on size effect. The mean fracture strength decreased from 22.9 MPa to 21.5 MPa as the diameter increased from 4 mm to 12 mm, and the mean strength of 15.9 mm diameter standard specimen, 20.9 MPa, was on the extended trend line. These fracture strength data indicate that in the given diameter range the size effect is not significant and much smaller than that predicted by the Weibull statistics-based model. Further, no noticeable size effect existed in the fracture toughness data, whose mean values were in a narrow range of 1.21 1.26 MPa. The Weibull moduli measured for fracture strength and fracture toughness datasets were around 10. It is therefore believed that the small or negligible size effect enables to use the subsize specimens and that the new fracture toughness test method to reuse the broken specimens to help minimize irradiation space and radioactive waste.« less

  2. A high temperature testing system for ceramic composites

    NASA Technical Reports Server (NTRS)

    Hemann, John

    1994-01-01

    Ceramic composites are presently being developed for high temperature use in heat engine and space power system applications. The operating temperature range is expected to be 1090 to 1650 C (2000 F to 3000 F). Very little material data is available at these temperatures and, therefore, it is desirable to thoroughly characterize the basic unidirectional fiber reinforced ceramic composite. This includes testing mainly for mechanical material properties at high temperatures. The proper conduct of such characterization tests requires the development of a tensile testing system includes unique gripping, heating, and strain measuring devices which require special considerations. The system also requires an optimized specimen shape. The purpose of this paper is to review various techniques for measuring displacements or strains, preferably at elevated temperatures. Due to current equipment limitations it is assumed that the specimen is to be tested at a temperature of 1430 C (2600F) in an oxidizing atmosphere. For the most part, previous high temperature material characterization tests, such as flexure and tensile tests, have been performed in inert atmospheres. Due to the harsh environment in which the ceramic specimen is to be tested, many conventional strain measuring techniques can not be applied. Initially a brief description of the more commonly used mechanical strain measuring techniques is given. Major advantages and disadvantages with their application to high temperature tensile testing of ceramic composites are discussed. Next, a general overview is given for various optical techniques. Advantages and disadvantages which are common to these techniques are noted. The optical methods for measuring strain or displacement are categorized into two sections. These include real-time techniques. Finally, an optical technique which offers optimum performance with the high temperature tensile testing of ceramic composites is recommended.

  3. Probabilistic thermal-shock strength testing using infrared imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wereszczak, A.A.; Scheidt, R.A.; Ferber, M.K.

    1999-12-01

    A thermal-shock strength-testing technique has been developed that uses a high-resolution, high-temperature infrared camera to capture a specimen's surface temperature distribution at fracture. Aluminum nitride (AlN) substrates are thermally shocked to fracture to demonstrate the technique. The surface temperature distribution for each test and AlN's thermal expansion are used as input in a finite-element model to determine the thermal-shock strength for each specimen. An uncensored thermal-shock strength Weibull distribution is then determined. The test and analysis algorithm show promise as a means to characterize thermal shock strength of ceramic materials.

  4. The accomplishments of lithium target and test facility validation activities in the IFMIF/EVEDA phase

    NASA Astrophysics Data System (ADS)

    Arbeiter, Frederik; Baluc, Nadine; Favuzza, Paolo; Gröschel, Friedrich; Heidinger, Roland; Ibarra, Angel; Knaster, Juan; Kanemura, Takuji; Kondo, Hiroo; Massaut, Vincent; Saverio Nitti, Francesco; Miccichè, Gioacchino; O'hira, Shigeru; Rapisarda, David; Sugimoto, Masayoshi; Wakai, Eiichi; Yokomine, Takehiko

    2018-01-01

    As part of the engineering validation and engineering design activities (EVEDA) phase for the international fusion materials irradiation facility IFMIF, major elements of a lithium target facility and the test facility were designed, prototyped and validated. For the lithium target facility, the EVEDA lithium test loop was built at JAEA and used to test the stability (waves and long term) of the lithium flow in the target, work out the startup procedures, and test lithium purification and analysis. It was confirmed by experiments in the Lifus 6 plant at ENEA that lithium corrosion on ferritic martensitic steels is acceptably low. Furthermore, complex remote handling procedures for the remote maintenance of the target in the test cell environment were successfully practiced. For the test facility, two variants of a high flux test module were prototyped and tested in helium loops, demonstrating their good capabilities of maintaining the material specimens at the desired temperature with a low temperature spread. Irradiation tests were performed for heated specimen capsules and irradiation instrumentation in the BR2 reactor at SCK-CEN. The small specimen test technique, essential for obtaining material test results with limited irradiation volume, was advanced by evaluating specimen shape and test technique influences.

  5. Metal-ceramic bond strength between a feldspathic porcelain and a Co-Cr alloy fabricated with Direct Metal Laser Sintering technique.

    PubMed

    Dimitriadis, Konstantinos; Spyropoulos, Konstantinos; Papadopoulos, Triantafillos

    2018-02-01

    The aim of the present study was to record the metal-ceramic bond strength of a feldspathic dental porcelain and a Co-Cr alloy, using the Direct Metal Laser Sintering technique (DMLS) for the fabrication of metal substrates. Ten metal substrates were fabricated with powder of a dental Co-Cr alloy using DMLS technique (test group) in dimensions according to ISO 9693. Another ten substrates were fabricated with a casing dental Co-Cr alloy using classic casting technique (control group) for comparison. Another three substrates were fabricated using each technique to record the Modulus of Elasticity ( E ) of the used alloys. All substrates were examined to record external and internal porosity. Feldspathic porcelain was applied on the substrates. Specimens were tested using the three-point bending test. The failure mode was determined using optical and scanning electron microscopy. The statistical analysis was performed using t-test. Substrates prepared using DMLS technique did not show internal porosity as compared to those produced using the casting technique. The E of control and test group was 222 ± 5.13 GPa and 227 ± 3 GPa, respectively. The bond strength was 51.87 ± 7.50 MPa for test group and 54.60 ± 6.20 MPa for control group. No statistically significant differences between the two groups were recorded. The mode of failure was mainly cohesive for all specimens. Specimens produced by the DMLS technique cover the lowest acceptable metal-ceramic bond strength of 25 MPa specified in ISO 9693 and present satisfactory bond strength for clinical use.

  6. Residual stress in glass: indentation crack and fractography approaches.

    PubMed

    Anunmana, Chuchai; Anusavice, Kenneth J; Mecholsky, John J

    2009-11-01

    To test the hypothesis that the indentation crack technique can determine surface residual stresses that are not statistically significantly different from those determined from the analytical procedure using surface cracks, the four-point flexure test, and fracture surface analysis. Soda-lime-silica glass bar specimens (4 mm x 2.3 mm x 28 mm) were prepared and annealed at 650 degrees C for 30 min before testing. The fracture toughness values of the glass bars were determined from 12 specimens based on induced surface cracks, four-point flexure, and fractographic analysis. To determine the residual stress from the indentation technique, 18 specimens were indented under 19.6N load using a Vickers microhardness indenter. Crack lengths were measured within 1 min and 24h after indentation, and the measured crack lengths were compared with the mean crack lengths of annealed specimens. Residual stress was calculated from an equation developed for the indentation technique. All specimens were fractured in a four-point flexure fixture and the residual stress was calculated from the strength and measured crack sizes on the fracture surfaces. The results show that there was no significant difference between the residual stresses calculated from the two techniques. However, the differences in mean residual stresses calculated within 1 min compared with those calculated after 24h were statistically significant (p=0.003). This study compared the indentation technique with the fractographic analysis method for determining the residual stress in the surface of soda-lime-silica glass. The indentation method may be useful for estimating residual stress in glass.

  7. Residual stress in glass: indentation crack and fractography approaches

    PubMed Central

    Anunmana, Chuchai; Anusavice, Kenneth J.; Mecholsky, John J.

    2009-01-01

    Objective To test the hypothesis that the indentation crack technique can determine surface residual stresses that are not statistically significantly different from those determined from the analytical procedure using surface cracks, the four-point flexure test, and fracture surface analysis. Methods Soda-lime-silica glass bar specimens (4 mm × 2.3 mm × 28 mm) were prepared and annealed at 650 °C for 30 min before testing. The fracture toughness values of the glass bars were determined from 12 specimens based on induced surface cracks, four-point flexure, and fractographic analysis. To determine the residual stress from the indentation technique, 18 specimens were indented under 19.6 N load using a Vickers microhardness indenter. Crack lengths were measured within 1 min and 24 h after indentation, and the measured crack lengths were compared with the mean crack lengths of annealed specimens. Residual stress was calculated from an equation developed for the indentation technique. All specimens were fractured in a four-point flexure fixture and the residual stress was calculated from the strength and measured crack sizes on the fracture surfaces. Results The results show that there was no significant difference between the residual stresses calculated from the two techniques. However, the differences in mean residual stresses calculated within 1 min compared with those calculated after 24 h were statistically significant (p=0.003). Significance This study compared the indentation technique with the fractographic analysis method for determining the residual stress in the surface of soda-lime silica glass. The indentation method may be useful for estimating residual stress in glass. PMID:19671475

  8. High-strain rate tensile characterization of graphite platelet reinforced vinyl ester based nanocomposites using split-Hopkinson pressure bar

    NASA Astrophysics Data System (ADS)

    Pramanik, Brahmananda

    The dynamic response of exfoliated graphite nanoplatelet (xGnP) reinforced and carboxyl terminated butadiene nitrile (CTBN) toughened vinyl ester based nanocomposites are characterized under both dynamic tensile and compressive loading. Dynamic direct tensile tests are performed applying the reverse impact Split Hopkinson Pressure Bar (SHPB) technique. The specimen geometry for tensile test is parametrically optimized by Finite Element Analysis (FEA) using ANSYS Mechanical APDLRTM. Uniform stress distribution within the specimen gage length has been verified using high-speed digital photography. The on-specimen strain gage installation is substituted by a non-contact Laser Occlusion Expansion Gage (LOEG) technique for infinitesimal dynamic tensile strain measurements. Due to very low transmitted pulse signal, an alternative approach based on incident pulse is applied for obtaining the stress-time history. Indirect tensile tests are also performed combining the conventional SHPB technique with Brazilian disk test method for evaluating cylindrical disk specimens. The cylindrical disk specimen is held snugly in between two concave end fixtures attached to the incident and transmission bars. Indirect tensile stress is estimated from the SHPB pulses, and diametrical transverse tensile strain is measured using LOEG. Failure diagnosis using high-speed digital photography validates the viability of utilizing this indirect test method for characterizing the tensile properties of the candidate vinyl ester based nanocomposite system. Also, quasi-static indirect tensile response agrees with previous investigations conducted using the traditional dog-bone specimen in quasi-static direct tensile tests. Investigation of both quasi-static and dynamic indirect tensile test responses show the strain rate effect on the tensile strength and energy absorbing capacity of the candidate materials. Finally, the conventional compressive SHPB tests are performed. It is observed that both strength and energy absorbing capacity of these candidate material systems are distinctively less under dynamic tension than under compressive loading. Nano-reinforcement appears to marginally improve these properties for pure vinyl ester under dynamic tension, although it is found to be detrimental under dynamic compression.

  9. Improved techniques for thermomechanical testing in support of deformation modeling

    NASA Technical Reports Server (NTRS)

    Castelli, Michael G.; Ellis, John R.

    1992-01-01

    The feasibility of generating precise thermomechanical deformation data to support constitutive model development was investigated. Here, the requirement is for experimental data that is free from anomalies caused by less than ideal equipment and procedures. A series of exploratory tests conducted on Hastelloy X showed that generally accepted techniques for strain controlled tests were lacking in at least three areas. Specifically, problems were encountered with specimen stability, thermal strain compensation, and temperature/mechanical strain phasing. The source of these difficulties was identified and improved thermomechanical testing techniques to correct them were developed. These goals were achieved by developing improved procedures for measuring and controlling thermal gradients and by designing a specimen specifically for thermomechanical testing. In addition, innovative control strategies were developed to correctly proportion and phase the thermal and mechanical components of strain. Subsequently, the improved techniques were used to generate deformation data for Hastelloy X over the temperature range, 200 to 1000 C.

  10. The detection of fatigue cracks by nondestructive testing methods

    NASA Technical Reports Server (NTRS)

    Rummel, W. D.; Todd, P. H., Jr.; Frecska, S. A.; Rathke, R. A.

    1974-01-01

    X-radiographic penetrant, ultrasonic, eddy current, holographic, and acoustic emission techniques were optimized and applied to the evaluation of 2219-T87 aluminum alloy test specimens. One hundred eighteen specimens containing a total of 328 fatigue cracks were evaluated. The cracks ranged in length from 0.500 inch (1.27 cm) to 0.007 inch (0.018 cm) and in depth from 0.178 inch (0.451 cm) and 0.001 inch (0.003 cm). Specimen thicknesses were nominally 0.060 inch (0.152 cm) and 0.210 inch (0.532 cm) and surface finishes were nominally 32 and 125 rms and 64 and 200 rms respectively. Specimens were evaluated in the as-milled surface condition, in the chemically milled surface condition and, after proof loading, in a randomized inspection sequence. Results of the nondestructive test (NDT) evaluations were compared with actual crack size obtained by measurement of the fractured specimens. Inspection data was then analyzed to provide a statistical basis for determinating the threshold crack detection sensitivity (the largest crack size that would be missed) for each of the inspection techniques at a 95% probability and 95% confidence level.

  11. Toughness characterization by small specimen test technique for HIPed joints of F82H steel aiming at first wall fabrication in fusion

    NASA Astrophysics Data System (ADS)

    Kishimoto, H.; Ono, T.; Sakasegawa, H.; Tanigawa, H.; Kohno, Y.; Kohyama, A.

    2013-09-01

    Reduced activation ferritic/martensitic steels (RAFMs), such as F82H steels, have been developed as candidates of structural materials for fusion. In the design of a fusion reactor, cooling channels are built in the first wall of the blanket. One large issue is to determine how to join rectangular tubes to thin panels to fabricate the first wall. Hot Isostatic Pressing (HIPing) is a solution to solve the issue. Because of the thin HIPed walls of the channels, the specimen size for inspection of HIPed interface is limited. In the present research, Small Specimen Test Techniques (SSTT) are screened for the destructive toughness investigation technique of HIPed F82H joints. 1/3 size Charpy V-notch impact (1/3 CVN) and small punch (SP) tests are employed for the present research. The toughness of the HIPed joints is strongly affected by various surface finishing of specimens treated previous to the HIPing. In the present research, several kinds of HIPed joints were surface finished by different methods and investigated by 1/3 CVN impact test. The HIPed F82H joints had different toughness ranging from 20% to 70% of the toughness of the F82H base metal. The SP test is also available for the investigation of toughness change by the HIPing. The sensitivity of 1/3 CVN impact test against toughness change was better than the SP test, it revealed that the SP test has some limitations.

  12. The width-tapered double cantilever beam for interlaminar fracture testing

    NASA Technical Reports Server (NTRS)

    Bascom, W. D.; Jensen, R. M.; Bullman, G. W.; Hunston, D. L.

    1984-01-01

    The width-tapered double-cantilever-beam (WTDCB) specimen configuration used to determine the Mode-I interlaminar fracture energy (IFE) of composites has special advantages for routine development work and for quality-assurance purposes. These advantages come primarily from the simplicity of testing and the fact that the specimen is designed for constant change in compliance with crack length, so that the computation of Mode-I IFE is independent of crack length. In this paper, a simplified technique for fabrication and testing WTDCB specimens is described. Also presented are the effects of fiber orientation and specimen dimensions, a comparison of data obtained using the WTDCB specimens and other specimen geometries, and comparison of data obtained at different laboratories. It is concluded that the WTDCB gives interlaminar Mode-I IFE essentially equal to other type specimens, and that it can be used for rapid screening in resin-development work and for quality assurance of composite materials.

  13. Biomechanical comparison between suture anchor and transtibial pull-out repair for posterior medial meniscus root tears.

    PubMed

    Feucht, Matthias J; Grande, Eduardo; Brunhuber, Johannes; Rosenstiel, Nikolaus; Burgkart, Rainer; Imhoff, Andreas B; Braun, Sepp

    2014-01-01

    Posterior medial meniscus root (PMMR) tears have a serious effect on knee joint biomechanics. Currently used techniques for refixation of the PMMR include the transtibial pull-out repair (TP) and suture anchor repair (SA). These techniques have not been compared biomechanically. The SA technique provides superior biomechanical properties compared with the TP technique. Controlled laboratory study. A total of 24 fresh-frozen porcine tibiae with attached intact medial menisci were used. The specimens were randomly assigned to 3 groups (8 specimens each). A standardized PMMR tear was created in 16 specimens. Refixation of the PMMR was performed by either the TP or SA technique. The native PMMR was left intact in 8 specimens. All specimens were subjected to cyclic loading followed by load-to-failure testing. Displacement after 100, 500, and 1000 cycles; maximum load to failure; stiffness; and displacement at failure were recorded. Both repair techniques showed a significantly higher displacement during cyclic loading and a significantly lower maximum load and stiffness during load-to-failure testing compared with the native PMMR (P < .05). The SA technique showed a significantly lower displacement after 100, 500, and 1000 cycles (P < .001) and a significantly higher stiffness (P = .016) compared with the TP technique. Maximum load did not differ significantly between the SA and TP techniques (P = .027, Bonferroni adjustment). No significant difference between the 3 groups was observed for displacement at failure (P > .05). The SA technique provided superior biomechanical properties compared with the TP technique. Both repair techniques did not reach the strength of the native PMMR. The favorable biomechanical properties of the SA technique might be beneficial for healing of the repaired PMMR and restoration of meniscus function. Because of inferior time zero stability compared with the native PMMR, slow rehabilitation is recommended after meniscus root repair.

  14. Investigation of temperature dependence of fracture toughness in high-dose HT9 steel using small-specimen reuse technique

    NASA Astrophysics Data System (ADS)

    Baek, Jong-Hyuk; Byun, Thak Sang; Maloy, Start A.; Toloczko, Mychailo B.

    2014-01-01

    The temperature dependence of fracture toughness in HT9 steel irradiated to 3-145 dpa at 380-503 °C was investigated using miniature three-point bend (TPB) fracture specimens. A miniature-specimen reuse technique has been established: the tested halves of subsize Charpy impact specimens with dimensions of 27 mm × 3 mm × 4 mm were reused for this fracture test campaign by cutting a notch with a diamond-saw in the middle of each half, and by fatigue-precracking to generate a sharp crack tip. It was confirmed that the fracture toughness of HT9 steel in the dose range depends more strongly on the irradiation temperature than the irradiation dose. At an irradiation temperature <430 °C, the fracture toughness of irradiated HT9 increased with the test temperature, reached an upper shelf of 180-200 MPa √{m} at 350-450 °C, and then decreased with the test temperature. At an irradiation temperature ⩾430 °C, the fracture toughness was nearly unchanged up to about 450 °C and decreased slowly with test temperatures in a higher temperature range. Such a rather monotonic test temperature dependence after high-temperature irradiation is similar to that observed for an archive material generally showing a higher degree of toughness. A brittle fracture without stable crack growth occurred in only a few specimens with relatively lower irradiation and test temperatures. In this discussion, these TPB fracture toughness data are compared with previously published data from 12.7 mm diameter disc compact tension (DCT) specimens.

  15. Investigation of temperature dependence of fracture toughness in high-dose HT9 steel using small-specimen reuse technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baek, Jong-Hyuk; Byun, Thak Sang; Maloy, S

    2014-01-01

    The temperature dependence of fracture toughness in HT9 steel irradiated to 3 145 dpa at 380 503 C was investigated using miniature three-point bend (TPB) fracture specimens. A miniature-specimen reuse technique has been established: the tested halves of subsize Charpy impact specimens with dimensions of 27 mm 3mm 4 mm were reused for this fracture test campaign by cutting a notch with a diamond-saw in the middle of each half, and by fatigue-precracking to generate a sharp crack tip. It was confirmed that the fracture toughness of HT9 steel in the dose range depends more strongly on the irradiation temperaturemore » than the irradiation dose. At an irradiation temperature <430 C, the fracture toughness of irradiated HT9 increased with the test temperature, reached an upper shelf of 180 200 MPa ffiffiffiffiffi m p at 350 450 C, and then decreased with the test temperature. At an irradiation temperatureP430 C, the fracture toughness was nearly unchanged up to about 450 C and decreased slowly with test temperatures in a higher temperature range. Such a rather monotonic test temperature dependence after high-temperature irradiation is similar to that observed for an archive material generally showing a higher degree of toughness. A brittle fracture without stable crack growth occurred in only a few specimens with relatively lower irradiation and test temperatures. In this discussion, these TPB fracture toughness data are compared with previously published data from 12.7 mm diameter disc compact tension (DCT) specimens.« less

  16. Metal-ceramic bond strength between a feldspathic porcelain and a Co-Cr alloy fabricated with Direct Metal Laser Sintering technique

    PubMed Central

    Spyropoulos, Konstantinos

    2018-01-01

    PURPOSE The aim of the present study was to record the metal-ceramic bond strength of a feldspathic dental porcelain and a Co-Cr alloy, using the Direct Metal Laser Sintering technique (DMLS) for the fabrication of metal substrates. MATERIALS AND METHODS Ten metal substrates were fabricated with powder of a dental Co-Cr alloy using DMLS technique (test group) in dimensions according to ISO 9693. Another ten substrates were fabricated with a casing dental Co-Cr alloy using classic casting technique (control group) for comparison. Another three substrates were fabricated using each technique to record the Modulus of Elasticity (E) of the used alloys. All substrates were examined to record external and internal porosity. Feldspathic porcelain was applied on the substrates. Specimens were tested using the three-point bending test. The failure mode was determined using optical and scanning electron microscopy. The statistical analysis was performed using t-test. RESULTS Substrates prepared using DMLS technique did not show internal porosity as compared to those produced using the casting technique. The E of control and test group was 222 ± 5.13 GPa and 227 ± 3 GPa, respectively. The bond strength was 51.87 ± 7.50 MPa for test group and 54.60 ± 6.20 MPa for control group. No statistically significant differences between the two groups were recorded. The mode of failure was mainly cohesive for all specimens. CONCLUSION Specimens produced by the DMLS technique cover the lowest acceptable metal-ceramic bond strength of 25 MPa specified in ISO 9693 and present satisfactory bond strength for clinical use. PMID:29503711

  17. Determination of fiber volume in graphite/epoxy materials using computer image analysis

    NASA Technical Reports Server (NTRS)

    Viens, Michael J.

    1990-01-01

    The fiber volume of graphite/epoxy specimens was determined by analyzing optical images of cross sectioned specimens using image analysis software. Test specimens were mounted and polished using standard metallographic techniques and examined at 1000 times magnification. Fiber volume determined using the optical imaging agreed well with values determined using the standard acid digestion technique. The results were found to agree within 5 percent over a fiber volume range of 45 to 70 percent. The error observed is believed to arise from fiber volume variations within the graphite/epoxy panels themselves. The determination of ply orientation using image analysis techniques is also addressed.

  18. Detection and Location of Transverse Matrix Cracks in Cross-Ply Gr/Ep Composites Using Acoustic Emission

    NASA Technical Reports Server (NTRS)

    Prosser, W. H.; Jackson, K. E.; Kellas, S.; Smith, B. T.; McKeon, J.; Friedman, A.

    1995-01-01

    Transverse matrix cracking in cross-ply gr/ep laminates was studied with advanced acoustic emission (AE) techniques. The primary goal of this research was to measure the load required to initiate the first transverse matrix crack in cross-ply laminates of different thicknesses. Other methods had been previously used for these measurements including penetrant enhanced radiography, optical microscopy, and audible acoustic microphone measurements. The former methods required that the mechanical test be paused for measurements at load intervals. This slowed the test procedure and did not provide the required resolution in load. With acoustic microphones, acoustic signals from cracks could not be clearly differentiated from other noise sources such as grip damage, specimen slippage, or test machine noise. A second goal for this work was to use the high resolution source location accuracy of the advanced acoustic emission techniques to determine whether the crack initiation site was at the specimen edge or in the interior of the specimen.In this research, advanced AE techniques using broad band sensors, high capture rate digital waveform acquisition, and plate wave propagation based analysis were applied to cross-ply composite coupons with different numbers of 0 and 90 degree plies. Noise signals, believed to be caused by grip damage or specimen slipping, were eliminated based on their plate wave characteristics. Such signals were always located outside the sensor gage length in the gripped region of the specimen. Cracks were confirmed post-test by microscopic analysis of a polished specimen edge, backscatter ultrasonic scans, and in limited cases, by penetrant enhanced radiography. For specimens with three or more 90 degree plies together, there was an exact 1-1 correlation between AE crack signals and observed cracks. The ultrasonic scans and some destructive sectioning analysis showed that the cracks extended across the full width of the specimen. Furthermore, the locations of the cracks from the AE data were in excellent agreement with the locations measured with the microscope. The high resolution source location capability of this technique, combined with an array of sensors, was able to determine that the cracks initiated at the specimen edges, rather than in the interior. For specimens with only one or two 90 degree plies, the crack-like signals were significantly smaller in amplitude and there was not a 1-1 correlation to observed cracks. This was similar to previous results. In this case, however, ultrasonic and destructive sectioning analysis revealed that the cracks did not extend across the specimen. They initiated at the edge, but did not propagate any appreciable distance into the specimen. This explains the much smaller AE signal amplitudes and the difficulty in correlating these signals to actual cracks in this, as well as in the previous study.

  19. Determination of Elastic Moduli of Fiber-Resin Composites Using an Impulse Excitation Technique

    NASA Technical Reports Server (NTRS)

    Viens, Michael J.; Johnson, Jeffrey J.

    1996-01-01

    The elastic moduli of graphite/epoxy and graphite/cyanate ester composite specimens with various laminate lay-ups was determined using an impulse excitation/acoustic resonance technique and compared to those determined using traditional strain gauge and extensometer techniques. The stiffness results were also compared to those predicted from laminate theory using uniaxial properties. The specimen stiffnesses interrogated ranged from 12 to 30 Msi. The impulse excitation technique was found to be a relatively quick and accurate method for determining elastic moduli with minimal specimen preparation and no requirement for mechanical loading frames. The results of this investigation showed good correlation between the elastic modulus determined using the impulse excitation technique, strain gauge and extensometer techniques, and modulus predicted from laminate theory. The flexural stiffness determined using the impulse excitation was in good agreement with that predicted from laminate theory. The impulse excitation/acoustic resonance interrogation technique has potential as a quality control test.

  20. The detection of tightly closed flaws by nondestructive testing (NDT) methods. [fatigue crack formation in aluminum alloy test specimens

    NASA Technical Reports Server (NTRS)

    Rummel, W. D.; Rathke, R. A.; Todd, P. H., Jr.; Mullen, S. J.

    1975-01-01

    Liquid penetrant, ultrasonic, eddy current and X-radiographic techniques were optimized and applied to the evaluation of 2219-T87 aluminum alloy test specimens in integrally stiffened panel, and weld panel configurations. Fatigue cracks in integrally stiffened panels, lack-of-fusion in weld panels, and fatigue cracks in weld panels were the flaw types used for evaluation. A 2319 aluminum alloy weld filler rod was used for all welding to produce the test specimens. Forty seven integrally stiffened panels containing a total of 146 fatigue cracks, ninety three lack-of-penetration (LOP) specimens containing a total of 239 LOP flaws, and one-hundred seventeen welded specimens containing a total of 293 fatigue cracks were evaluated. Nondestructive test detection reliability enhancement was evaluated during separate inspection sequences in the specimens in the 'as-machined or as-welded', post etched and post proof loaded conditions. Results of the nondestructive test evaluations were compared to the actual flaw size obtained by measurement of the fracture specimens after completing all inspection sequences. Inspection data were then analyzed to provide a statistical basis for determining the flaw detection reliability.

  1. Energy efficient engine shroudless, hollow fan blade technology report

    NASA Technical Reports Server (NTRS)

    Michael, C. J.

    1981-01-01

    The Shroudless, Hollow Fan Blade Technology program was structured to support the design, fabrication, and subsequent evaluation of advanced hollow and shroudless blades for the Energy Efficient Engine fan component. Rockwell International was initially selected to produce hollow airfoil specimens employing the superplastic forming/diffusion bonding (SPF/DB) fabrication technique. Rockwell demonstrated that a titanium hollow structure could be fabricated utilizing SPF/DB manufacturing methods. However, some problems such as sharp internal cavity radii and unsatisfactory secondary bonding of the edge and root details prevented production of the required quantity of fatigue test specimens. Subsequently, TRW was selected to (1) produce hollow airfoil test specimens utilizing a laminate-core/hot isostatic press/diffusion bond approach, and (2) manufacture full-size hollow prototype fan blades utilizing the technology that evolved from the specimen fabrication effort. TRW established elements of blade design and defined laminate-core/hot isostatic press/diffusion bonding fabrication techniques to produce test specimens. This fabrication technology was utilized to produce full size hollow fan blades in which the HIP'ed parts were cambered/twisted/isothermally forged, finish machined, and delivered to Pratt & Whitney Aircraft and NASA for further evaluation.

  2. Rapid repair of severely earthquake-damaged bridge piers with flexural-shear failure mode

    NASA Astrophysics Data System (ADS)

    Sun, Zhiguo; Wang, Dongsheng; Du, Xiuli; Si, Bingjun

    2011-12-01

    An experimental study was conducted to investigate the feasibility of a proposed rapid repair technique for severely earthquake-damaged bridge piers with flexural-shear failure mode. Six circular pier specimens were first tested to severe damage in flexural-shear mode and repaired using early-strength concrete with high-fluidity and carbon fiber reinforced polymers (CFRP). After about four days, the repaired specimens were tested to failure again. The seismic behavior of the repaired specimens was evaluated and compared to the original specimens. Test results indicate that the proposed repair technique is highly effective. Both shear strength and lateral displacement of the repaired piers increased when compared to the original specimens, and the failure mechanism of the piers shifted from flexural-shear failure to ductile flexural failure. Finally, a simple design model based on the Seible formulation for post-earthquake repair design was compared to the experimental results. It is concluded that the design equation for bridge pier strengthening before an earthquake could be applicable to seismic repairs after an earthquake if the shear strength contribution of the spiral bars in the repaired piers is disregarded and 1.5 times more FRP sheets is provided.

  3. [Evaluation of Xpert® MTB/RIF technique for Mycobacterium tuberculosis complex detection in extra-respiratory specimens].

    PubMed

    García, Patricia; Balcells, M Elvira; Castillo, Claudia; Miranda, Carolina; Geoffroy, Enrique; Román, Juan C; Wozniak, Aniela

    2017-08-01

    Extra-pulmonary tuberculosis (TB) represents the 26.2% of total TB cases in Chile. Culture is the gold standard method, but the process is extremely slow. Xpert®MTB/RIF technique detects Mycobacterium tuberculosis complex (MTBc) through real time PCR in less than 3 h. However, it has been validated only for respiratory specimens. We aimed to determine the performance of Xpert®MTB/RIF test in detecting MTBc in extra-respiratory specimens compared with a combined gold standard consisting in a positive (liquid and solid) mycobacterial culture and/or a positive validated molecular method (q-RPC, Cobas®TaqMan®-MTB). Fifty extra-respiratory specimens were analyzed, from which 25 were positive and 25 negative for MTBc based on the combined gold standard. The 25 positive specimens had a positive result by Xpert®MTB/RIF; from the 25 negative specimens, 24 had a negative result and one had a positive result. We obtained an overall concordance of 98% between Xpert®MTB/RIF and the combined gold standard. Xpert®MTB/RIF test was able to detect 12 smear-negative specimens and 3 culture-negative specimens, all of them corresponding to extra-pulmonary TB cases. Xpert®MTB/RIF showed similar sensitivity to q-RPC in detecting MTBc in extra-respiratory specimens. This procedure allowed a substantial reduction in the time of diagnosis.

  4. Perspectives of SiC-Based Ceramic Composites and Their Applications to Fusion Reactors 5.Development of Evaluation and Application Techniques of SiC⁄SiC Composites for Fusion Reactors

    NASA Astrophysics Data System (ADS)

    Hinoki, Tatsuya

    Evaluation techniques and mechanical properties of silicon carbide composites (SiC⁄SiC composites) reinforced with highly crystalline fibers are reviewed for fusion applications. The SiC⁄SiC composites used were fabricated by means of the CVI method. The evaluation includes in-plane tensile strength by in-plane tensile test, transthickness tensile strength by transthickness tensile test and diametral compression test and shear strength by compression test using double-notched specimen. All tests were successfully conducted using small specimens for neutron irradiation experiment. As application technique, the novel tungsten(W) coating technique on SiC is reviewed. The W powder melted by high power lamp in a few seconds and formed coating on SiC. No thick reaction layers of WC and W5Si3, which are formed by the other coating methods, were formed by this method.

  5. Investigation of temperature dependence of fracture toughness in high-dose HT9 steel using small-specimen reuse technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baek, Jong-Hyuk; Byun, Thak Sang; Maloy, Stuart A.

    2014-01-01

    The temperature dependence of fracture toughness in HT9 steel irradiated to 3–145 dpa at 380–503 degrees*C was investigated using miniature three-point bend (TPB) fracture specimens. A miniature-specimen reuse technique has been established: the tested halves of subsize Charpy impact specimens with dimensions of 27 mm *3mm* 4 mm were reused for this fracture test campaign by cutting a notch with a diamond-saw in the middle of each half, and by fatigue-precracking to generate a sharp crack tip. It was confirmed that the fracture toughness of HT9 steel in the dose range depends more strongly on the irradiation temperature than themore » irradiation dose. At an irradiation temperature <430 *degreesC, the fracture toughness of irradiated HT9 increased with the test temperature, reached an upper shelf of 180—200 MPa*m^.5 at 350–450 degrees*C, and then decreased with the test temperature. At an irradiation temperature >430 degrees*C, the fracture toughness was nearly unchanged up to about 450 *degreesC and decreased slowly with test temperatures in a higher temperature range. Such a rather monotonic test temperature dependence after high-temperature irradiation is similar to that observed for an archive material generally showing a higher degree of toughness. A brittle fracture without stable crack growth occurred in only a few specimens with relatively lower irradiation and test temperatures. In this discussion, these TPB fracture toughness data are compared with previously published data from 12.7 mm diameter disc compact tension (DCT) specimens.« less

  6. Slow crack growth in spinel in water

    NASA Technical Reports Server (NTRS)

    Schwantes, S.; Elber, W.

    1983-01-01

    Magnesium aluminate spinel was tested in a water environment at room temperature to establish its slow crack-growth behavior. Ring specimens with artificial flaws on the outside surface were loaded hydraulically on the inside surface. The time to failure was measured. Various precracking techniques were evaluated and multiple precracks were used to minimize the scatter in the static fatigue tests. Statistical analysis techniques were developed to determine the strength and crack velocities for a single flaw. Slow crack-growth rupture was observed at stress intensities as low as 70 percent of K sub c. A strengthening effect was observed in specimens that had survived long-time static fatigue tests.

  7. Critical assessment of precracked specimen configuration and experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate

    NASA Technical Reports Server (NTRS)

    Domack, M. S.

    1985-01-01

    A research program was conducted to critically assess the effects of precracked specimen configuration, stress intensity solutions, compliance relationships and other experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate. Modified compact and double beam wedge-loaded specimens were tested and analyzed to determine the threshold stress intensity factor and stress corrosion crack growth rate. Stress intensity solutions and experimentally determined compliance relationships were developed and compared with other solutions available in the literature. Crack growth data suggests that more effective crack length measurement techniques are necessary to better characterize stress corrosion crack growth. Final load determined by specimen reloading and by compliance did not correlate well, and was considered a major source of interlaboratory variability. Test duration must be determined systematically, accounting for crack length measurement resolution, time for crack arrest, and experimental interferences. This work was conducted as part of a round robin program sponsored by ASTM committees G1.06 and E24.04 to develop a standard test method for stress corrosion testing using precracked specimens.

  8. Specimen size effects on ductile?brittle transition temperature in Charpy impact testing

    NASA Astrophysics Data System (ADS)

    Kurishita, H.; Yamamoto, T.; Narui, M.; Suwarno, H.; Yoshitake, T.; Yano, Y.; Yamazaki, M.; Matsui, H.

    2004-08-01

    One key issue for small specimen test techniques is to clarify specimen size effects on test results. In consideration of size effects on determining the ductile-to-brittle transition temperature (DBTT) in Charpy impact testing, a method to evaluate the plastic constraint loss for differently sized Charpy V-notch (CVN) specimens is proposed and applied to a ferritic-martensitic steel, 2WFK, developed by JNC. In the method, a constraint factor, α, that is an index of the plastic constraint is defined as α=σ ∗/σ y∗. Here, σ ∗ is the critical cleavage fracture stress which is a material constant and σ y∗ is the uniaxial yield stress at the DBTT at the strain rate generated in the Charpy impact test. The procedures for evaluating each of σ ∗ and σ y∗ are described and a result of σ ∗ and σ y∗, thus the value of α, is presented for different types of miniaturized and full-sized CVN specimens of 2WFK.

  9. Strain controlled cyclic tests on miniaturized specimens

    NASA Astrophysics Data System (ADS)

    Procházka, R.; Džugan, J.

    2017-02-01

    The paper is dealing with strain controlled cyclic tests using a non-contact strain measurement based on digital image correlation techniques on proportional sizes of conventional specimens. The cyclic behaviour of 34CrNiMo6 high-strength steel was investigated on miniaturized round specimens with diameter of 2mm that were compared with specimens in accordance with ASTM E606 standards. The cycle asymmetry coefficient was R= -1. This application is intended to be used for life time assessment of in service components in future work which enables to carried out a group of mechanical tests from a limited amount of the experimental material. The attention was paid to confirm the suitability of the proposed size miniaturization geometry, testing set up and procedure. The test results obtained enabled to construct Manson-Coffin curves and assess fatigue parameters. The purpose of this study is to present differences between cyclic curves and cyclic parameters which have been evaluated based on conventional and miniaturized specimens.

  10. Assessment of Composite Delamination Self-Healing Under Cyclic Loading

    NASA Technical Reports Server (NTRS)

    O'Brien, T. Kevin

    2009-01-01

    Recently, the promise of self-healing materials for enhanced autonomous durability has been introduced using a micro-encapsulation technique where a polymer based healing agent is encapsulated in thin walled spheres and embedded into a base polymer along with a catalyst phase. For this study, composite skin-stiffener flange debonding specimens were manufactured from composite prepreg containing interleaf layers with a polymer based healing agent encapsulated in thin-walled spheres. Constant amplitude fatigue tests in three-point bending showed the effect of self-healing on the fatigue response of the skin-stiffener flange coupons. After the cycling that created debonding, fatigue tests were held at the mean load for 24 hours. For roughly half the specimens tested, when the cyclic loading was resumed a decrease in compliance (increase in stiffness) was observed, indicating that some healing had occurred. However, with continued cycling, the specimen compliance eventually increased to the original level before the hold, indicating that the damage had returned to its original state. As was noted in a prevoius study conducted with specimens tested under monotonically increasing loads to failure, healing achieved via the micro-encapsulation technique may be limited to the volume of healing agent available relative to the crack volume.

  11. Use of Marker Bands for Determination of Fatigue Crack Growth Rates and Crack Front Shapes in Pre-Corroded Coupons

    NASA Technical Reports Server (NTRS)

    Willard, S. A.

    1997-01-01

    Groups of striations called marker bands generated on a fatigue fracture surface can be used to mark the position of an advancing fatigue crack at known intervals. A technique has been developed that uses the distance between multiple sets of marker bands to obtain a vs. N, crack front shape, and fatigue crack growth rate data for small cracks. This technique is particularly usefull for specimens that require crack length measurements during testing that cannot be obtained because corrosion obscures the surface of the specimen. It is also useful for specimens with unusual or non-symmetric shapes where it is difficult to obtain accurate crack lengths using traditional methods such as compliance or electric potential difference in the early stages of testing.

  12. Fiber Bragg Gratings, IT Techniques and Strain Gauge Validation for Strain Calculation on Aged Metal Specimens

    PubMed Central

    Montero, Ander; de Ocariz, Idurre Saez; Lopez, Ion; Venegas, Pablo; Gomez, Javier; Zubia, Joseba

    2011-01-01

    This paper studies the feasibility of calculating strains in aged F114 steel specimens with Fiber Bragg Grating (FBG) sensors and infrared thermography (IT) techniques. Two specimens have been conditioned under extreme temperature and relative humidity conditions making comparative tests of stress before and after aging using different adhesives. Moreover, a comparison has been made with IT techniques and conventional methods for calculating stresses in F114 steel. Implementation of Structural Health Monitoring techniques on real aircraft during their life cycle requires a study of the behaviour of FBG sensors and their wiring under real conditions, before using them for a long time. To simulate aging, specimens were stored in a climate chamber at 70 °C and 90% RH for 60 days. This study is framed within the Structural Health Monitoring (SHM) and Non Destructuve Evaluation (NDE) research lines, integrated into the avionics area maintained by the Aeronautical Technologies Centre (CTA) and the University of the Basque Country (UPV/EHU). PMID:22346619

  13. Application of high-speed photography to the study of high-strain-rate materials testing

    NASA Astrophysics Data System (ADS)

    Ruiz, D.; Harding, John; Noble, J. P.; Hillsdon, Graham K.

    1991-04-01

    There is a growing interest in material behaviour at strain rates greater than 104sec1, for instance in the design of aero-engine turbine blades. It is necessary therefore, to develop material testing techniques that give well-defined information on mechanical behaviour in this very high strain-rate regime. A number of techniques are available, including the expanding ring test1, a miniaturised compression Hopkinson bar technique using direct impact and the double-notch shear test3 which has been described by Nicholas4 as "one of the most promising for future studies in dynamic plasticity". However, although it is believed to be a good test for determining the flow stress at shear strain rates of 104sec and above, the design of specimen used makes an accurate determination of strain extremely difficult while, in the later stages of the test the deformation mode involves rotation as well as shear. If this technique is to be used, therefore, it is necessary to examine in detail the progressive deformation and state of stress within the specimen during the impact process. An attempt can then be made to assess how far the data obtained is a reliable measure of the specimen material response and the test can be calibrated. An extensive three stage analysis has been undertaken. In the first stage, reported in a previous paper5, the initial elastic behaviour was studied. Dynamic photoelastic experiments were used to support linear elastic numerical results derived by the finite element method. Good qualitative agreement was obtained between the photoelastic experiment and the numerical model and the principal source of error in the elastic region of the double-notch shear test was identified as the assumption that all deformation of the specimen is concentrated in the two shear zones. For the epoxy (photoelastic) specimen a calibration factor of 5.3 was determined. This factor represents the ratio between the defined (nominal) gauge length and the effective gauge length. The second stage of the analysis of the double-notch shear (DNS) specimen is described in this paper. This consists of the use of ultra-high speed photography to provide information on the plastic deformation behaviour of the specimen. Two different high speed cine cameras were used for this work, a Hadland "Imacon" 792 electronic image converter camera and a Cordin 377 rotating mirror-drum optical camera. Implementation of the two cameras and photographic results are briefly compared and contrasted here. Stage three of this work consists of an advanced numerical analysis of the elasto-plastic, strain rate dependent behaviour of the DNS specimen. The principle intention of the authors was to use the physical data collected from high speed photographs for correlation with this work. Full details of the numerical work are presented elsewhere6 but some salient results will be given here for completeness.

  14. Delamination growth in composite materials

    NASA Technical Reports Server (NTRS)

    Gillespie, J. W., Jr.; Carlsson, L. A.; Pipes, R. B.; Rothschilds, R.; Trethewey, B.; Smiley, A.

    1986-01-01

    The Double Cantilever Beam (DCB) and the End Notched Flexure (ENF) specimens are employed to characterize MODE I and MODE II interlaminar fracture resistance of graphite/epoxy (CYCOM 982) and graphite/PEEK (APC2) composites. Sizing of test specimen geometries to achieve crack growth in the linear elastic regime is presented. Data reduction schemes based upon beam theory are derived for the ENF specimen and include the effects of shear deformation and friction between crack surfaces on compliance, C, and strain energy release rate, G sub II. Finite element (FE) analyses of the ENF geometry including the contact problem with friction are presented to assess the accuracy of beam theory expressions for C and G sub II. Virtual crack closure techniques verify that the ENF specimen is a pure Mode II test. Beam theory expressions are shown to be conservative by 20 to 40 percent for typical unidirectional test specimen geometries. A FE parametric study investigating the influence of delamination length and depth, span, thickness and material properties on G sub II is presented. Mode I and II interlaminar fracture test results are presented. Important experimental parameters are isolated, such as precracking techniques, rate effects, and nonlinear load-deflection response. It is found that subcritical crack growth and inelastic materials behavior, responsible for the observed nonlinearities, are highly rate-dependent phenomena with high rates generally leading to linear elastic response.

  15. Improved method for determining the stress relaxation at the crack tip

    NASA Astrophysics Data System (ADS)

    Grinevich, A. V.; Erasov, V. S.; Avtaev, V. V.

    2017-10-01

    A technique is suggested to determine the stress relaxation at the crack tip during tests of a specimen of a new type at a constant crack opening fixed by a stay bolt. The shape and geometry of the specimen make it possible to set the load and to determine the crack closure force after long-term exposure using the force transducer of a tensile-testing machine. The stress relaxation at the crack tip is determined in a V95pchT2 alloy specimen at elevated temperatures.

  16. Progress in speckle-shift strain measurement

    NASA Technical Reports Server (NTRS)

    Lant, Christian T.; Barranger, John P.; Oberle, Lawrence G.; Greer, Lawrence C., III

    1991-01-01

    The Instrumentation and Control Technology Division of the Lewis Research Center has been developing an in-house capability to make one dimensional and two dimensional optical strain measurements on high temperature test specimens. The measurements are based on a two-beam speckle-shift technique. The development of composite materials for use in high temperature applications is generating interest in using the speckle-shift technique to measure strains on small diameter fibers and wires of various compositions. The results of preliminary speckle correlation tests on wire and fiber specimens are covered, and the advanced system currently under development is described.

  17. A technique for magnetic resonance imaging of equine cadaver specimens.

    PubMed

    Widmer, W R; Buckwalter, K A; Hill, M A; Fessler, J F; Ivancevich, S

    1999-01-01

    We tested an adaptation of a technique for performing magnetic resonance (MR) imaging of human cadaver limbs in the horse. The forelimbs from a normal horse were collected, frozen, and sealed with a paraffin-polymer combination prior to imaging with either a high- or midfield magnetic resonance scanner. Each forelimb was defrosted, scanned, and refrozen on two separate occasions. A five-point scale was used to evaluate the quality of each set of sagittal and transverse, T1-weighted images of each digit. There was no difference in image quality between first and second scans of either specimen (p > 0.05). We conclude that this technique allows investigators to bank tissue specimens for future magnetic resonance imaging without significant loss of image quality.

  18. Effect of soldering techniques and gap distance on tensile strength of soldered Ni-Cr alloy joint.

    PubMed

    Lee, Sang-Yeob; Lee, Jong-Hyuk

    2010-12-01

    The present study was intended to evaluate the effect of soldering techniques with infrared ray and gas torch under different gap distances (0.3 mm and 0.5 mm) on the tensile strength and surface porosity formation in Ni-Cr base metal alloy. Thirty five dumbbell shaped Ni-Cr alloy specimens were prepared and assigned to 5 groups according to the soldering method and the gap distance. For the soldering methods, gas torch (G group) and infrared ray (IR group) were compared and each group was subdivided by corresponding gap distance (0.3 mm: G3 and IR3, 0.5 mm: G5, IR5). Specimens of the experimental groups were sectioned in the middle with a diamond disk and embedded in solder blocks according to the predetermined distance. As a control group, 7 specimens were prepared without sectioning or soldering. After the soldering procedure, a tensile strength test was performed using universal testing machine at a crosshead speed 1 mm/min. The proportions of porosity on the fractured surface were calculated on the images acquired through the scanning electronic microscope. Every specimen of G3, G5, IR3 and IR5 was fractured on the solder joint area. However, there was no significant difference between the test groups (P > .05). There was a negative correlation between porosity formation and tensile strength in all the specimens in the test groups (P < .05). There was no significant difference in ultimate tensile strength of joints and porosity formations between the gas-oxygen torch soldering and infrared ray soldering technique or between the gap distance of 0.3 mm and 0.5 mm.

  19. Effect of soldering techniques and gap distance on tensile strength of soldered Ni-Cr alloy joint

    PubMed Central

    Lee, Sang-Yeob

    2010-01-01

    PURPOSE The present study was intended to evaluate the effect of soldering techniques with infrared ray and gas torch under different gap distances (0.3 mm and 0.5 mm) on the tensile strength and surface porosity formation in Ni-Cr base metal alloy. MATERIALS AND METHODS Thirty five dumbbell shaped Ni-Cr alloy specimens were prepared and assigned to 5 groups according to the soldering method and the gap distance. For the soldering methods, gas torch (G group) and infrared ray (IR group) were compared and each group was subdivided by corresponding gap distance (0.3 mm: G3 and IR3, 0.5 mm: G5, IR5). Specimens of the experimental groups were sectioned in the middle with a diamond disk and embedded in solder blocks according to the predetermined distance. As a control group, 7 specimens were prepared without sectioning or soldering. After the soldering procedure, a tensile strength test was performed using universal testing machine at a crosshead speed 1 mm/min. The proportions of porosity on the fractured surface were calculated on the images acquired through the scanning electronic microscope. RESULTS Every specimen of G3, G5, IR3 and IR5 was fractured on the solder joint area. However, there was no significant difference between the test groups (P > .05). There was a negative correlation between porosity formation and tensile strength in all the specimens in the test groups (P < .05). CONCLUSION There was no significant difference in ultimate tensile strength of joints and porosity formations between the gas-oxygen torch soldering and infrared ray soldering technique or between the gap distance of 0.3 mm and 0.5 mm. PMID:21264189

  20. Computer-aided analysis for the Mechanics of Granular Materials (MGM) experiment, part 2

    NASA Technical Reports Server (NTRS)

    Parker, Joey K.

    1987-01-01

    Computer vision based analysis for the MGM experiment is continued and expanded into new areas. Volumetric strains of granular material triaxial test specimens have been measured from digitized images. A computer-assisted procedure is used to identify the edges of the specimen, and the edges are used in a 3-D model to estimate specimen volume. The results of this technique compare favorably to conventional measurements. A simplified model of the magnification caused by diffraction of light within the water of the test apparatus was also developed. This model yields good results when the distance between the camera and the test specimen is large compared to the specimen height. An algorithm for a more accurate 3-D magnification correction is also presented. The use of composite and RGB (red-green-blue) color cameras is discussed and potentially significant benefits from using an RGB camera are presented.

  1. Characterization of irradiated AISI 316L stainless steel disks removed from the Spallation Neutron Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vevera, Bradley J; Hyres, James W; McClintock, David A

    2014-01-01

    Irradiated AISI 316L stainless steel disks were removed from the Spallation Neutron Source (SNS) for post-irradiation examination (PIE) to assess mechanical property changes due to radiation damage and erosion of the target vessel. Topics reviewed include high-resolution photography of the disk specimens, cleaning to remove mercury (Hg) residue and surface oxides, profile mapping of cavitation pits using high frequency ultrasonic testing (UT), high-resolution surface replication, and machining of test specimens using wire electrical discharge machining (EDM), tensile testing, Rockwell Superficial hardness testing, Vickers microhardness testing, scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDS). The effectiveness of the cleaning proceduremore » was evident in the pre- and post-cleaning photography and permitted accurate placement of the test specimens on the disks. Due to the limited amount of material available and the unique geometry of the disks, machine fixturing and test specimen design were critical aspects of this work. Multiple designs were considered and refined during mock-up test runs on unirradiated disks. The techniques used to successfully machine and test the various specimens will be presented along with a summary of important findings from the laboratory examinations.« less

  2. Experimental validation of a new heterogeneous mechanical test design

    NASA Astrophysics Data System (ADS)

    Aquino, J.; Campos, A. Andrade; Souto, N.; Thuillier, S.

    2018-05-01

    Standard material parameters identification strategies generally use an extensive number of classical tests for collecting the required experimental data. However, a great effort has been made recently by the scientific and industrial communities to support this experimental database on heterogeneous tests. These tests can provide richer information on the material behavior allowing the identification of a more complete set of material parameters. This is a result of the recent development of full-field measurements techniques, like digital image correlation (DIC), that can capture the heterogeneous deformation fields on the specimen surface during the test. Recently, new specimen geometries were designed to enhance the richness of the strain field and capture supplementary strain states. The butterfly specimen is an example of these new geometries, designed through a numerical optimization procedure where an indicator capable of evaluating the heterogeneity and the richness of strain information. However, no experimental validation was yet performed. The aim of this work is to experimentally validate the heterogeneous butterfly mechanical test in the parameter identification framework. For this aim, DIC technique and a Finite Element Model Up-date inverse strategy are used together for the parameter identification of a DC04 steel, as well as the calculation of the indicator. The experimental tests are carried out in a universal testing machine with the ARAMIS measuring system to provide the strain states on the specimen surface. The identification strategy is accomplished with the data obtained from the experimental tests and the results are compared to a reference numerical solution.

  3. Characterizing Facesheet/Core Disbonding in Honeycomb Core Sandwich Structure

    NASA Technical Reports Server (NTRS)

    Rinker, Martin; Ratcliffe, James G.; Adams, Daniel O.; Krueger, Ronald

    2013-01-01

    Results are presented from an experimental investigation into facesheet core disbonding in carbon fiber reinforced plastic/Nomex honeycomb sandwich structures using a Single Cantilever Beam test. Specimens with three, six and twelve-ply facesheets were tested. Specimens with different honeycomb cores consisting of four different cell sizes were also tested, in addition to specimens with three different widths. Three different data reduction methods were employed for computing apparent fracture toughness values from the test data, namely an area method, a compliance calibration technique and a modified beam theory method. The compliance calibration and modified beam theory approaches yielded comparable apparent fracture toughness values, which were generally lower than those computed using the area method. Disbonding in the three-ply facesheet specimens took place at the facesheet/core interface and yielded the lowest apparent fracture toughness values. Disbonding in the six and twelve-ply facesheet specimens took place within the core, near to the facesheet/core interface. Specimen width was not found to have a significant effect on apparent fracture toughness. The amount of scatter in the apparent fracture toughness data was found to increase with honeycomb core cell size.

  4. A Validation Study of the Impression Replica Technique.

    PubMed

    Segerström, Sofia; Wiking-Lima de Faria, Johanna; Braian, Michael; Ameri, Arman; Ahlgren, Camilla

    2018-04-17

    To validate the well-known and often-used impression replica technique for measuring fit between a preparation and a crown in vitro. The validation consisted of three steps. First, a measuring instrument was validated to elucidate its accuracy. Second, a specimen consisting of male and female counterparts was created and validated by the measuring instrument. Calculations were made for the exact values of three gaps between the male and female. Finally, impression replicas were produced of the specimen gaps and sectioned into four pieces. The replicas were then measured with the use of a light microscope. The values received from measuring the specimen were then compared with the values received from the impression replicas, and the technique was thereby validated. The impression replica technique overvalued all measured gaps. Depending on location of the three measuring sites, the difference between the specimen and the impression replicas varied from 47 to 130 μm. The impression replica technique overestimates gaps within the range of 2% to 11%. The validation of the replica technique enables the method to be used as a reference when testing other methods for evaluating fit in dentistry. © 2018 by the American College of Prosthodontists.

  5. Finite element analysis of the end notched flexure specimen for measuring Mode II fracture toughness

    NASA Technical Reports Server (NTRS)

    Gillespie, J. W., Jr.; Carlsson, L. A.; Pipes, R. B.

    1986-01-01

    The paper presents a finite element analysis of the end-notched flexure (ENF) test specimen for Mode II interlaminar fracture testing of composite materials. Virtual crack closure and compliance techniques employed to calculate strain energy release rates from linear elastic two-dimensional analysis indicate that the ENF specimen is a pure Mode II fracture test within the constraints of small deflection theory. Furthermore, the ENF fracture specimen is shown to be relatively insensitive to process-induced cracks, offset from the laminate midplane. Frictional effects are investigated by including the contact problem in the finite element model. A parametric study investigating the influence of delamination length, span, thickness, and material properties assessed the accuracy of beam theory expressions for compliance and strain energy release rate, GII. Finite element results indicate that data reduction schemes based upon beam theory underestimate GII by approximately 20-40 percent for typical unidirectional graphite fiber composite test specimen geometries. Consequently, an improved data reduction scheme is proposed.

  6. A study of environmental characterization of conventional and advanced aluminum alloys for selection and design. Phase 2: The breaking load test method

    NASA Technical Reports Server (NTRS)

    Sprowls, D. O.; Bucci, R. J.; Ponchel, B. M.; Brazill, R. L.; Bretz, P. E.

    1984-01-01

    A technique is demonstrated for accelerated stress corrosion testing of high strength aluminum alloys. The method offers better precision and shorter exposure times than traditional pass fail procedures. The approach uses data from tension tests performed on replicate groups of smooth specimens after various lengths of exposure to static stress. The breaking strength measures degradation in the test specimen load carrying ability due to the environmental attack. Analysis of breaking load data by extreme value statistics enables the calculation of survival probabilities and a statistically defined threshold stress applicable to the specific test conditions. A fracture mechanics model is given which quantifies depth of attack in the stress corroded specimen by an effective flaw size calculated from the breaking stress and the material strength and fracture toughness properties. Comparisons are made with experimental results from three tempers of 7075 alloy plate tested by the breaking load method and by traditional tests of statistically loaded smooth tension bars and conventional precracked specimens.

  7. NDE of structural ceramics

    NASA Technical Reports Server (NTRS)

    Klima, S. J.; Vary, A.

    1986-01-01

    Radiographic, ultrasonic, scanning laser acoustic microscopy (SLAM), and thermo-acoustic microscopy techniques were used to characterize silicon nitride and silicon carbide modulus-of-rupture test specimens in various stages of fabrication. Conventional and microfocus X-ray techniques were found capable of detecting minute high density inclusions in as-received powders, green compacts, and fully densified specimens. Significant density gradients in sintered bars were observed by radiography, ultrasonic velocity, and SLAM. Ultrasonic attenuation was found sensitive to microstructural variations due to grain and void morphology and distribution. SLAM was also capable of detecting voids, inclusions and cracks in finished test bars. Consideration is given to the potential for applying thermo-acoustic microscopy techniques to green and densified ceramics. The detection probability statistics and some limitations of radiography and SLAM also are discussed.

  8. Evaluation of the intercept oral specimen collection device with HIV assays versus paired serum/plasma specimens.

    PubMed

    Beelaert, G; Van Heddegem, L; Van Frankenhuijsen, M; Vandewalle, G; Compernolle, V; Florence, E; Fransen, K

    2016-08-01

    Oral fluid has many advantages over blood-based techniques: it is less invasive, eliminates the occupational risk associated with needle stick accidents and collection can be self-administrated. Each individual test is packaged with a corresponding collection device. This study tested the suitability of the Intercept Oral Specimen Collection Device for different HIV diagnostic tests: three different rapid HIV tests and two adapted ELISAs, which were evaluated and compared with a gold standard on blood. In addition a total IgG quantification was performed to demonstrate the quality of the specimen. HIV antibodies were detected with a sensitivity of 100%, 99.3%, 98.6%, 100% and 95.7% for, DPP, OraQuick, Aware, Genscreen and Vironostika respectively using the Intercept Collection Device. Respective specificities were 100%, 100%, 99.3%, 97.3% and 100%. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. A Modified Edge Crack Torsion Test for Measurement of Mode III Fracture Toughness of Laminated Tape Composites

    NASA Technical Reports Server (NTRS)

    Czabaj, Michael W.; Davidson, Barry D.; Ratcliffe, James G.

    2016-01-01

    Modifications to the edge crack torsion (ECT) test are studied to improve the reliability of this test for measuring the mode-III fracture toughness, G (sub IIIc), of laminated tape fiber-reinforced polymeric (FRP) composites. First, the data reduction methods currently used in the ECT test are evaluated and deficiencies in their accuracy are discussed. An alternative data reduction technique, which uses a polynomial form to represent ECT specimen compliance solution, is evaluated and compared to FEA (finite element analysis) results. Second, seven batches of ECT specimens are tested, each batch containing specimens with a preimplanted midplane edge delamination and midplane plies with orientations of plus theta divided by minus theta, with theta ranging from 0 degrees to 90 degrees in 15-degree increments. Tests on these specimens show that intralaminar cracking occurs in specimens from all batches except for which theta = 15 degrees and 30 degrees. Tests on specimens of these two batches are shown to result in mode-III delamination growth at the intended ply interface. The findings from this study are encouraging steps towards the use of the ECT test as a standardized method for measuring G (sub IIIc), although further modification to the data reduction method is required to make it suitable for use as part of a standardized test method.

  10. A biomechanical comparison of the Rogers interspinous and the Lovely-Carl tension band wiring techniques for fixation of the cervical spine.

    PubMed

    Brasil, A V; Coehlo, D G; Filho, T E; Braga, F M

    2000-07-01

    The authors conducted a biomechanical study in which they compared the uses of the Rogers interspinous and the Lovely-Carl tension band wiring techniques for internal fixation of the cervical spine. An extensive biomechanical evaluation (stiffness in positive and negative rotations around the x, y, and z axes; range of motion in flexion-extension, bilateral axial rotation, and bilateral bending; and neutral zone in flexion-extension, bilateral axial rotation, and lateral bending to the right and to the left) was performed in two groups of intact calf cervical spines. After these initial tests, all specimens were subjected to a distractive flexion Stage 3 ligamentous lesion. Group 1 specimens then underwent surgical fixation by the Rogers technique, and Group 2 specimens underwent surgery by using the Lovely-Carl technique. After fixation, specimens were again submitted to the same biomechanical evaluation. The percentage increase or decrease between the pre- and postoperative parameters was calculated. These values were considered quantitative indicators of the efficacy of the techniques, and the efficacy of the two techniques was compared. Analysis of the findings demonstrated that in the spines treated with the Lovely-Carl technique less restriction of movement was produced without affecting stiffness, compared with those treated with the Rogers technique, thus making the Lovely-Carl technique clinically less useful.

  11. Investigation of interfacial fracture behavior on injection molded parts

    NASA Astrophysics Data System (ADS)

    Fischer, Matthieu; Ausias, Gilles; Kuehnert, Ines

    2016-03-01

    In this study the interfacial morphology of different polymers joined by various assembly injection molding (AIM) technologies were discussed. Melt streams were injected successively using tools with core-back or rotation techniques. To compare bulk specimen strength and weld line strength, the fracture behavior of different specimen scales and thin sections were investigated. An in-situ SEM tensile test and a new thin section testing device which is used in polarized (transmitted) light microscopy were used to observe specimen failure. The effects of processing on spherulitic structures were linked to bonding strength and mechanical properties.

  12. Ultrasonic linear array validation via concrete test blocks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoegh, Kyle, E-mail: hoeg0021@umn.edu; Khazanovich, Lev, E-mail: hoeg0021@umn.edu; Ferraro, Chris

    2015-03-31

    Oak Ridge National Laboratory (ORNL) comparatively evaluated the ability of a number of NDE techniques to generate an image of the volume of 6.5′ X 5.0′ X 10″ concrete specimens fabricated at the Florida Department of Transportation (FDOT) NDE Validation Facility in Gainesville, Florida. These test blocks were fabricated to test the ability of various NDE methods to characterize various placements and sizes of rebar as well as simulated cracking and non-consolidation flaws. The first version of the ultrasonic linear array device, MIRA [version 1], was one of 7 different NDE equipment used to characterize the specimens. This paper dealsmore » with the ability of this equipment to determine subsurface characterizations such as reinforcing steel relative size, concrete thickness, irregularities, and inclusions using Kirchhoff-based migration techniques. The ability of individual synthetic aperture focusing technique (SAFT) B-scan cross sections resulting from self-contained scans are compared with various processing, analysis, and interpretation methods using the various features fabricated in the specimens for validation. The performance is detailed, especially with respect to the limitations and implications for evaluation of a thicker, more heavily reinforced concrete structures.« less

  13. Can extra-articular strains be used to measure facet contact forces in the lumbar spine? An in-vitro biomechanical study.

    PubMed

    Zhu, Q A; Park, Y B; Sjovold, S G; Niosi, C A; Wilson, D C; Cripton, P A; Oxland, T R

    2008-02-01

    Experimental measurement of the load-bearing patterns of the facet joints in the lumbar spine remains a challenge, thereby limiting the assessment of facet joint function under various surgical conditions and the validation of computational models. The extra-articular strain (EAS) technique, a non-invasive measurement of the contact load, has been used for unilateral facet joints but does not incorporate strain coupling, i.e. ipsilateral EASs due to forces on the contralateral facet joint. The objectives of the present study were to establish a bilateral model for facet contact force measurement using the EAS technique and to determine its effectiveness in measuring these facet joint contact forces during three-dimensional flexibility tests in the lumbar spine. Specific goals were to assess the accuracy and repeatability of the technique and to assess the effect of soft-tissue artefacts. In the accuracy and repeatability tests, ten uniaxial strain gauges were bonded to the external surface of the inferior facets of L3 of ten fresh lumbar spine specimens. Two pressure-sensitive sensors (Tekscan) were inserted into the joints after the capsules were cut. Facet contact forces were measured with the EAS and Tekscan techniques for each specimen in flexion, extension, axial rotation, and lateral bending under a +/- 7.5 N m pure moment. Four of the ten specimens were tested five times in axial rotation and extension for repeatability. These same specimens were disarticulated and known forces were applied across the facet joint using a manual probe (direct accuracy) and a materials-testing system (disarticulated accuracy). In soft-tissue artefact tests, a separate set of six lumbar spine specimens was used to document the virtual facet joint contact forces during a flexibility test following removal of the superior facet processes. Linear strain coupling was observed in all specimens. The average peak facet joint contact forces during flexibility testing was greatest in axial rotation (71 +/- 25 N), followed by extension (27 +/- 35 N) and lateral bending (25 +/- 28 N), and they were most repeatable in axial rotation (coefficient of variation, 5 per cent). The EAS accuracy was about 20 per cent in the direct accuracy assessment and about 30 per cent in the disarticulated accuracy test. The latter was very similar to the Tekscan accuracy in the same test. Virtual facet loads (r.m.s.) were small in axial rotation (12 N) and lateral bending (20 N), but relatively large in flexion (34 N) and extension (35 N). The results suggested that the bilateral EAS model could be used to determine the facet joint contact forces in axial rotation but may result in considerable error in flexion, extension, and lateral bending.

  14. Comparison of contemporary occipitocervical instrumentation techniques with and without C1 lateral mass screws.

    PubMed

    Wolfla, Christopher E; Salerno, Simon A; Yoganandan, Narayan; Pintar, Frank A

    2007-09-01

    This study was designed to test the kinematic properties of three occiput-C2 instrumentation constructs with and without supplemental rigid C1 fixation. The results are compared with intact specimens and with constructs incorporating contemporary cabling techniques. Five unembalmed human cadaver specimens underwent range of motion (ROM) testing in the intact condition, followed by destabilization with odontoid osteotomy. Destabilized specimens then underwent ROM testing with each of seven occipitocervical instrumentation constructs, all incorporating occipital screws: C1 and C2 sublaminar cables with cable connectors, C2 pars screws +/- C1 lateral mass screws, C2 lamina screws +/- C1 lateral mass screws, and C1-C2 transarticular screws +/- C1 lateral mass screws. All seven constructs demonstrated significantly lower ROM in all loading modes than intact specimens (P < 0.05). With a single exception, the addition of C1 lateral mass screws to the screw-based constructs produced no significant change in ROM in any of the loading modes. Compared with intact specimens, constructs anchored by C1-C2 transarticular screws demonstrated the greatest decrease in ROM, and those anchored by sublaminar cables demonstrated the least decrease in ROM. Any of the tested screw-based constructs are likely to provide adequate support for the patient with an unstable craniocervical junction. Therefore, the choice of construct should be based on anatomic considerations. The routine incorporation of C1 lateral mass screws into occipitocervical instrumentation constructs does not seem necessary.

  15. Analysis of HER2 status in breast carcinoma by fully automated HER2 fluorescence in situ hybridization (FISH): comparison of two immunohistochemical tests and manual FISH.

    PubMed

    Yoon, Nara; Do, In-Gu; Cho, Eun Yoon

    2014-09-01

    Easy and accurate HER2 testing is essential when considering the prognostic and predictive significance of HER2 in breast cancer. The use of a fully automated, quantitative FISH assay would be helpful to detect HER2 amplification in breast cancer tissue specimens with reduced inter-laboratory variability. We compared the concordance of HER2 status as assessed by an automated FISH staining system to manual FISH testing. Using 60 formalin-fixed paraffin-embedded breast carcinoma specimens, we assessed HER2 immunoexpression with two antibodies (DAKO HercepTest and CB11). In addition, HER2 status was evaluated with automated FISH using the Leica FISH System for BOND and a manual FISH using the Abbott PathVysion DNA Probe Kit. All but one specimen were successfully stained using both FISH methods. When the data were divided into two groups according to HER2/CEP17 ratio, positive and negative, the results from both the automated and manual FISH techniques were identical for all 59 evaluable specimens. The HER2 and CEP17 copy numbers and HER2/CEP17 ratio showed great agreement between both FISH methods. The automated FISH technique was interpretable with signal intensity similar to those of the manual FISH technique. In contrast with manual FISH, the automated FISH technique showed well-preserved architecture due to low membrane digestion. HER2 immunohistochemistry and FISH results showed substantial significant agreement (κ = 1.0, p < 0.001). HER2 status can be reliably determined using a fully automated HER2 FISH system with high concordance to the well-established manual FISH method. Because of stable signal intensity and high staining quality, the automated FISH technique may be more appropriate than manual FISH for routine applications. © 2013 APMIS. Published by John Wiley & Sons Ltd.

  16. Capillary Versus Aspiration Biopsy: Effect of Needle Size and Length on the Cytopathological Specimen Quality

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hopper, Kenneth D.; Grenko, Ronald T.; Fisher, Alicia I.

    1996-09-15

    Purpose: To test the value of the nonaspiration, or capillary, biopsy technique by experimental comparison with the conventional fine-needle aspiration technique using various needle gauges and lengths. Methods: On fresh hepatic and renal tissue from five autopsies, multiple biopsy specimens were taken with 20, 22, and 23-gauge Chiba needles of 5, 10, 15, and 20-cm length, using the aspiration technique and the capillary technique. The resultant specimens were graded on the basis of a grading scheme by a cytopathologist who was blinded to the biopsy technique. Results: The capillary technique obtained less background blood or clot which could obscure diagnosticmore » tissue, although not significantly different from the aspiration technique (p= 0.2). However, for the amount of cellular material obtained, retention of appropriate architecture, and mean score, the capillary technique performed statistically worse than aspiration biopsy (p < 0.01). In addition, with decreasing needle caliber (increasing needle gauge) and increasing length, the capillary biopsy was inferior to the aspiration biopsy. Conclusion: The capillary biopsy technique is inferior to the aspiration technique according to our study. When the capillary technique is to be applied, preference should be given to larger caliber, shorter needles.« less

  17. ADAPTATION OF CRACK GROWTH DETECTION TECHNIQUES TO US MATERIAL TEST REACTORS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    A. Joseph Palmer; Sebastien P. Teysseyre; Kurt L. Davis

    2015-04-01

    A key component in evaluating the ability of Light Water Reactors to operate beyond 60 years is characterizing the degradation of materials exposed to radiation and various water chemistries. Of particular concern is the response of reactor materials to Irradiation Assisted Stress Corrosion Cracking (IASCC). Some test reactors outside the United States, such as the Halden Boiling Water Reactor (HBWR), have developed techniques to measure crack growth propagation during irradiation. The basic approach is to use a custom-designed compact loading mechanism to stress the specimen during irradiation, while the crack in the specimen is monitored in-situ using the Direct Currentmore » Potential Drop (DCPD) method. In 2012 the US Department of Energy commissioned the Idaho National Laboratory and the MIT Nuclear Reactor Laboratory (MIT NRL) to take the basic concepts developed at the HBWR and adapt them to a test rig capable of conducting in-pile IASCC tests in US Material Test Reactors. The first two and half years of the project consisted of designing and testing the loader mechanism, testing individual components of the in-pile rig and electronic support equipment, and autoclave testing of the rig design prior to insertion in the MIT Reactor. The load was applied to the specimen by means of a scissor like mechanism, actuated by a miniature metal bellows driven by pneumatic pressure and sized to fit within the small in-core irradiation volume. In addition to the loader design, technical challenges included developing robust connections to the specimen for the applied current and voltage measurements, appropriate ceramic insulating materials that can endure the LWR environment, dealing with the high electromagnetic noise environment of a reactor core at full power, and accommodating material property changes in the specimen, due primarily to fast neutron damage, which change the specimen resistance without additional crack growth. The project culminated with an in-pile demonstration at the MIT Reactor. The test rig and associated support equipment were used to apply loads to a representative Compact Tensile specimen during one MITR operating cycle, while measuring crack growth using the DCPD method. Although the test period was short (approximately 70 days), and the accumulated neutron dose relatively small, successful operation of the test rig was demonstrated. The specimen was cycled more than 8000 times (more than would be typical for a long term IASCC test), which was sufficient to propagate a crack of over 2 mm.« less

  18. Detection of tightly closed flaws by nondestructive testing (NDT) methods in steel and titanium

    NASA Technical Reports Server (NTRS)

    Rummel, W. D.; Rathke, R. A.; Todd, P. H., Jr.; Tedrow, T. L.; Mullen, S. J.

    1976-01-01

    X-radiographic, liquid penetrant, ultrasonic, eddy current and magnetic particle testing techniques were optimized and applied to the evaluation of 4340 steel (180 KSI-UTS) and 6Al-4V titanium (STA) alloy specimens. Sixty steel specimens containing a total of 176 fatigue cracks and 60 titanium specimens containing a total of 135 fatigue cracks were evaluated. The cracks ranged in length from .043 cm (0.017 inch) to 1.02 cm (.400 inch) and in depth from .005 cm (.002 inch) to .239 cm (.094 inch) for steel specimens. Lengths ranged from .048 cm (0.019 inch) to 1.03 cm (.407 inch) and depths from 0.010 cm (.004 inch) to .261 cm (0.103 inch) for titanium specimens. Specimen thicknesses were nominally .152 cm (0.060 inch) and 0.635 cm (0.250 inch) and surface finishes were nominally 125 rms. Specimens were evaluated in the "as machined" surface condition, after etch surface and after proof loading in a randomized inspection sequence.

  19. Characterization of 316L(N)-IG SS joint produced by hot isostatic pressing technique

    NASA Astrophysics Data System (ADS)

    Nakano, J.; Miwa, Y.; Tsukada, T.; Kikuchi, M.; Kita, S.; Nemoto, Y.; Tsuji, H.; Jitsukawa, S.

    2002-12-01

    Type 316L(N) stainless steel of the international thermonuclear experimental reactor grade (316L(N)-IG SS) is being considered for the first wall/blanket module. Hot isostatic pressing (HIP) technique is expected for the fabrication of the module. To evaluate the integrity and susceptibility to stress corrosion cracking (SCC) of HIPed 316L(N)-IG SS, tensile tests in vacuum and slow strain rate tests in high temperature water were performed. Specimen with the HIPed joint had similar tensile properties to specimens of 316L(N)-IG SS, and did not show susceptibility to SCC in oxygenated water at 423 K. Thermally sensitized specimen was low susceptible to SCC even in the creviced condition. It is concluded that the tensile properties of HIPed SS are as high as those of the base alloy and the HIP process caused no deleterious effects.

  20. Bonding and nondestructive evaluation of graphite/PEEK composite and titanium adherends with thermoplastic adhesives

    NASA Technical Reports Server (NTRS)

    Hodges, W. T.; Tyeryar, J. R.; Berry, M.

    1985-01-01

    Bonded single overlap shear specimens were fabricated from Graphite/PEEK (Polyetheretherketone) composite adherends and titanium adherends. Six advanced thermoplastic adhesives were used for the bonding. The specimens were bonded by an electromagnetic induction technique producing high heating rates and high-strength bonds in a few minutes. This contrasts with conventionally heated presses or autoclaves that take hours to process comparable quality bonds. The Graphite/PEEK composites were highly resistant to delamination during the testing. This allowed the specimen to fail exclusively through the bondline, even at very high shear loads. Nondestructive evaluation of bonded specimens was performed ultrasonically by energizing the entire thickness of the material through the bondline and measuring acoustic impedance parameters. Destructive testing confirmed the unique ultrasonic profiles of strong and weak bonds, establishing a standard for predicting relative bond strength in subsequent specimens.

  1. On the design of innovative heterogeneous tests using a shape optimization approach

    NASA Astrophysics Data System (ADS)

    Aquino, J.; Campos, A. Andrade; Souto, N.; Thuillier, S.

    2018-05-01

    The development of full-field measurement methods enabled a new trend of mechanical tests. By providing the inhomogeneous strain field from the tests, these techniques are being widely used in sheet metal identification strategies, through heterogeneous mechanical tests. In this work, a heterogeneous mechanical test with an innovative tool/specimen shape, capable of producing rich heterogeneous strain paths providing extensive information on material behavior, is aimed. The specimen is found using a shape optimization process where a dedicated indicator that evaluates the richness of strain information is used. The methodology and results here presented are extended to non-specimen geometry dependence and to the non-dependence of the geometry parametrization through the use of the Ritz method for boundary value problems. Different curve models, such as Splines, B-Splines and NURBS, are used and C1 continuity throughout the specimen is guaranteed. Moreover, various optimization methods are used, deterministic and stochastic, in order to find the method or a combination of methods able to effectively minimize the cost function.

  2. Dynamic acousto-elastic testing of concrete with a coda-wave probe: comparison with standard linear and nonlinear ultrasonic techniques.

    PubMed

    Shokouhi, Parisa; Rivière, Jacques; Lake, Colton R; Le Bas, Pierre-Yves; Ulrich, T J

    2017-11-01

    The use of nonlinear acoustic techniques in solids consists in measuring wave distortion arising from compliant features such as cracks, soft intergrain bonds and dislocations. As such, they provide very powerful nondestructive tools to monitor the onset of damage within materials. In particular, a recent technique called dynamic acousto-elasticity testing (DAET) gives unprecedented details on the nonlinear elastic response of materials (classical and non-classical nonlinear features including hysteresis, transient elastic softening and slow relaxation). Here, we provide a comprehensive set of linear and nonlinear acoustic responses on two prismatic concrete specimens; one intact and one pre-compressed to about 70% of its ultimate strength. The two linear techniques used are Ultrasonic Pulse Velocity (UPV) and Resonance Ultrasound Spectroscopy (RUS), while the nonlinear ones include DAET (fast and slow dynamics) as well as Nonlinear Resonance Ultrasound Spectroscopy (NRUS). In addition, the DAET results correspond to a configuration where the (incoherent) coda portion of the ultrasonic record is used to probe the samples, as opposed to a (coherent) first arrival wave in standard DAET tests. We find that the two visually identical specimens are indistinguishable based on parameters measured by linear techniques (UPV and RUS). On the contrary, the extracted nonlinear parameters from NRUS and DAET are consistent and orders of magnitude greater for the damaged specimen than those for the intact one. This compiled set of linear and nonlinear ultrasonic testing data including the most advanced technique (DAET) provides a benchmark comparison for their use in the field of material characterization. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Strain Rate Dependency of Bronze Metal Matrix Composite Mechanical Properties as a Function of Casting Technique

    NASA Astrophysics Data System (ADS)

    Brown, Lloyd; Joyce, Peter; Radice, Joshua; Gregorian, Dro; Gobble, Michael

    2012-07-01

    Strain rate dependency of mechanical properties of tungsten carbide (WC)-filled bronze castings fabricated by centrifugal and sedimentation-casting techniques are examined, in this study. Both casting techniques are an attempt to produce a functionally graded material with high wear resistance at a chosen surface. Potential applications of such materials include shaft bushings, electrical contact surfaces, and brake rotors. Knowledge of strain rate-dependent mechanical properties is recommended for predicting component response due to dynamic loading or impact events. A brief overview of the casting techniques for the materials considered in this study is followed by an explanation of the test matrix and testing techniques. Hardness testing, density measurement, and determination of the volume fraction of WC particles are performed throughout the castings using both image analysis and optical microscopy. The effects of particle filling on mechanical properties are first evaluated through a microhardness survey of the castings. The volume fraction of WC particles is validated using a thorough density survey and a rule-of-mixtures model. Split Hopkinson Pressure Bar (SHPB) testing of various volume fraction specimens is conducted to determine strain dependence of mechanical properties and to compare the process-property relationships between the two casting techniques. The baseline performances of C95400 bronze are provided for comparison. The results show that the addition of WC particles improves microhardness significantly for the centrifugally cast specimens, and, to a lesser extent, in the sedimentation-cast specimens, largely because the WC particles are more concentrated as a result of the centrifugal-casting process. Both metal matrix composites (MMCs) demonstrate strain rate dependency, with sedimentation casting having a greater, but variable, effects on material response. This difference is attributed to legacy effects from the casting process, namely, porosity and localized WC particle grouping.

  4. [Research status and prospects of DNA test on difficult specimens].

    PubMed

    Dang, Hua-Wei; Mao, Jiong; Wang, Hui; Huang, Jiang-Ping; Bai, Xiao-Gang

    2012-02-01

    This paper reviews the advances of DNA detection on three types of difficult biological specimens including degraded samples, trace evidences and mixed samples. The source of different samples, processing methods and announcements were analyzed. New methods such as mitochondrial test system, changing the original experimental conditions, low-volume PCR amplification and new technologies such as whole genome amplification techniques, laser capture micro-dissection, and mini-STR technology in recent years are introduced.

  5. Dimensional changes of acrylic resin denture bases: conventional versus injection-molding technique.

    PubMed

    Gharechahi, Jafar; Asadzadeh, Nafiseh; Shahabian, Foad; Gharechahi, Maryam

    2014-07-01

    Acrylic resin denture bases undergo dimensional changes during polymerization. Injection molding techniques are reported to reduce these changes and thereby improve physical properties of denture bases. The aim of this study was to compare dimensional changes of specimens processed by conventional and injection-molding techniques. SR-Ivocap Triplex Hot resin was used for conventional pressure-packed and SR-Ivocap High Impact was used for injection-molding techniques. After processing, all the specimens were stored in distilled water at room temperature until measured. For dimensional accuracy evaluation, measurements were recorded at 24-hour, 48-hour and 12-day intervals using a digital caliper with an accuracy of 0.01 mm. Statistical analysis was carried out by SPSS (SPSS Inc., Chicago, IL, USA) using t-test and repeated-measures ANOVA. Statistical significance was defined at P<0.05. After each water storage period, the acrylic specimens produced by injection exhibited less dimensional changes compared to those produced by the conventional technique. Curing shrinkage was compensated by water sorption with an increase in water storage time decreasing dimensional changes. Within the limitations of this study, dimensional changes of acrylic resin specimens were influenced by the molding technique used and SR-Ivocap injection procedure exhibited higher dimensional accuracy compared to conventional molding.

  6. Dimensional Changes of Acrylic Resin Denture Bases: Conventional Versus Injection-Molding Technique

    PubMed Central

    Gharechahi, Jafar; Asadzadeh, Nafiseh; Shahabian, Foad; Gharechahi, Maryam

    2014-01-01

    Objective: Acrylic resin denture bases undergo dimensional changes during polymerization. Injection molding techniques are reported to reduce these changes and thereby improve physical properties of denture bases. The aim of this study was to compare dimensional changes of specimens processed by conventional and injection-molding techniques. Materials and Methods: SR-Ivocap Triplex Hot resin was used for conventional pressure-packed and SR-Ivocap High Impact was used for injection-molding techniques. After processing, all the specimens were stored in distilled water at room temperature until measured. For dimensional accuracy evaluation, measurements were recorded at 24-hour, 48-hour and 12-day intervals using a digital caliper with an accuracy of 0.01 mm. Statistical analysis was carried out by SPSS (SPSS Inc., Chicago, IL, USA) using t-test and repeated-measures ANOVA. Statistical significance was defined at P<0.05. Results: After each water storage period, the acrylic specimens produced by injection exhibited less dimensional changes compared to those produced by the conventional technique. Curing shrinkage was compensated by water sorption with an increase in water storage time decreasing dimensional changes. Conclusion: Within the limitations of this study, dimensional changes of acrylic resin specimens were influenced by the molding technique used and SR-Ivocap injection procedure exhibited higher dimensional accuracy compared to conventional molding. PMID:25584050

  7. Evaluation of fluorescent-antibody tests as a means of confirming infant botulism.

    PubMed Central

    Glasby, C; Hatheway, C L

    1984-01-01

    Fluorescent-antibody techniques were evaluated for confirming infant botulism. Seventy-seven stool specimens from suspected cases were examined. All 34 specimens containing viable Clostridium botulinum at time of study gave positive results (29 on direct smears and 34 on enrichments). Two false-positive reactions were observed. Images PMID:6394626

  8. Double Cantilever Beam and End Notched Flexure Fracture Toughness Testing of Two Composite Materials

    NASA Technical Reports Server (NTRS)

    Kessler, Jeff A.; Adams, Donald F.

    1993-01-01

    Two different unidirectional composite materials were provided by NASA Langley Research Center and tested by the Composite Materials Research Group within the Department of Mechanical Engineering at the University of Wyoming. Double cantilever beam and end notched flexure tests were performed to measure the mode I (crack opening) and mode II (sliding or shear) interlaminar fracture toughness of the two materials. The two composites consisted of IM7 carbon fiber combined with either RP46 resin toughened with special formulation of LaRC IA resin, known as JJS1356; or PES chain extended thermoplastic resin known as JJS1361. Double Cantilever Beam Specimen Configuration and Test Methods As received from NASA, the test specimens were nominally 0.5 inch wide, 6 inches long, and 0.2 inch thick. A 1 inch long Kapton insert at the midplane of one end of the specimen (placed during laminate fabrication) facilitated crack initiation and extension. It was noted that the specimens provided were smaller than the nominal 1.5 inch wide, 9.0 inch long configuration specified. Similarly, the Kapton inserts were of greater length than those in the present specimens. Hence, the data below should not be compared directly to those generated with the referenced methods. No preconditioning was performed on the specimens prior to testing. In general, the methodology was used for the present work. Crack opening loads were introduced to the specimens via piano hinges attached to the main specimen faces at a single end of each specimen. Hinges were bolted to the specimens using the technique presented. The cracks were extended a small distance from the end of the Kapton insert prior to testing. Just before precracking, the sides of the specimens were coated with water-soluble typewriter correction fluid to aid in crack visualization. Scribe marks were then made in the coating at half-inch intervals.

  9. Antibody class capture assay (ACCA) for rubella-specific IgM antibody.

    PubMed

    Isaac, M; Payne, R A

    1982-01-01

    Enzyme-linked immunosorbent assays for IgM antirubella were carried out on 1,546 sera, using an IgM capture method with a F (ab')2 conjugate (ACCA). Under the conditions described, sera containing IgM antirubella bound up to 15 times as much enzyme activity as negative specimens. Paired serum specimens from 27 patients, serial serum specimens from 6 patients, and single serum specimens from 15 patients who had had recent rubella were examined by the haemagglutination inhibition test (HAI) in the presence and absence of 2-mercaptoethanol following sucrose density gradient centrifugation (SDGC). ACCA confirmed all the results found with HAI following SDGC. Specimens were examined from ten patients with congenital rubella; ACCA confirmed the results found with both immunofluorescence following SDGC and radioimmunoassay. Pre- and post-vaccination specimens from 123 patients who had been vaccinated against rubella were examined. An IgM response could only be demonstrated in the 57 cases when IgG was absent in the first specimen. The specificity of the assay was confirmed by testing 31 serum specimens from rubella immune patients that also contained rheumatoid factor, 163 serum specimens from patients with acute infections other than rubella, and 12 serum specimens from infants with miscellaneous neonatal abnormalities other than congenital rubella. The ACCA proved a simple, sensitive, and specific test for IgM antirubella and the results compared favourably with those obtained by the SDGC technique.

  10. [Research progress on mechanical performance evaluation of artificial intervertebral disc].

    PubMed

    Li, Rui; Wang, Song; Liao, Zhenhua; Liu, Weiqiang

    2018-03-01

    The mechanical properties of artificial intervertebral disc (AID) are related to long-term reliability of prosthesis. There are three testing methods involved in the mechanical performance evaluation of AID based on different tools: the testing method using mechanical simulator, in vitro specimen testing method and finite element analysis method. In this study, the testing standard, testing equipment and materials of AID were firstly introduced. Then, the present status of AID static mechanical properties test (static axial compression, static axial compression-shear), dynamic mechanical properties test (dynamic axial compression, dynamic axial compression-shear), creep and stress relaxation test, device pushout test, core pushout test, subsidence test, etc. were focused on. The experimental techniques using in vitro specimen testing method and testing results of available artificial discs were summarized. The experimental methods and research status of finite element analysis were also summarized. Finally, the research trends of AID mechanical performance evaluation were forecasted. The simulator, load, dynamic cycle, motion mode, specimen and test standard would be important research fields in the future.

  11. Laser welding of a cobalt-chromium removable partial denture alloy.

    PubMed

    NaBadalung, D P; Nicholls, J I

    1998-03-01

    The electric alloy brazed joints of removable partial denture alloys have failed frequently after routine usage. A technique providing higher joint strengths was investigated. This investigation compared the tensile strengths of electric-brazed and laser-welded joints for a cobalt-chromium removable partial denture alloy. Twenty-four cobalt-chromium standard tensile testing rods were prepared and divided into three groups of eight. All specimens in the control group (group 1) were left in the as-cast condition. Groups 2 and 3 were the test specimens, which were sectioned at the center of the rod. Eight specimens were joined by using electric brazing, and the remaining specimens were joined by using laser welding. After joining, each joint was ground to a uniform diameter, then tested to tensile failure on an Instron universal testing machine. Failure loads were recorded and fracture stress calculated. Statistical analysis was applied. The student-Newman-Keuls test showed a highly significant difference between the joint strengths of the as-cast control specimens, the electric-brazed and laser-welded joints. The tensile strengths of the as-cast joints were higher than those for the laser-welded joints, and both were higher than the electric-brazed joint strengths.

  12. Molecular Diagnostic Testing for Aspergillus

    PubMed Central

    Powers-Fletcher, Margaret V.

    2016-01-01

    The direct detection of Aspergillus nucleic acid in clinical specimens has the potential to improve the diagnosis of aspergillosis by offering more rapid and sensitive identification of invasive infections than is possible with traditional techniques, such as culture or histopathology. Molecular tests for Aspergillus have been limited historically by lack of standardization and variable sensitivities and specificities. Recent efforts have been directed at addressing these limitations and optimizing assay performance using a variety of specimen types. This review provides a summary of standardization efforts and outlines the complexities of molecular testing for Aspergillus in clinical mycology. PMID:27487954

  13. Airborne non-contact and contact broadband ultrasounds for frequency attenuation profile estimation of cementitious materials.

    PubMed

    Gosálbez, J; Wright, W M D; Jiang, W; Carrión, A; Genovés, V; Bosch, I

    2018-08-01

    In this paper, the study of frequency-dependent ultrasonic attenuation in strongly heterogeneous cementitious materials is addressed. To accurately determine the attenuation over a wide frequency range, it is necessary to have suitable excitation techniques. We have analysed two kinds of ultrasound techniques: contact ultrasound and airborne non-contact ultrasound. The mathematical formulation for frequency-dependent attenuation has been established and it has been revealed that each technique may achieve similar results but requires specific different calibration processes. In particular, the airborne non-contact technique suffers high attenuation due to energy losses at the air-material interfaces. Thus, its bandwidth is limited to low frequencies but it does not require physical contact between transducer and specimen. In contrast, the classical contact technique can manage higher frequencies but the measurement depends on the pressure between the transducer and the specimen. Cement specimens have been tested with both techniques and frequency attenuation dependence has been estimated. Similar results were achieved at overlapping bandwidth and it has been demonstrated that the airborne non-contact ultrasound technique could be a viable alternative to the classical contact technique. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Quantifying dynamic mechanical properties of human placenta tissue using optimization techniques with specimen-specific finite-element models.

    PubMed

    Hu, Jingwen; Klinich, Kathleen D; Miller, Carl S; Nazmi, Giseli; Pearlman, Mark D; Schneider, Lawrence W; Rupp, Jonathan D

    2009-11-13

    Motor-vehicle crashes are the leading cause of fetal deaths resulting from maternal trauma in the United States, and placental abruption is the most common cause of these deaths. To minimize this injury, new assessment tools, such as crash-test dummies and computational models of pregnant women, are needed to evaluate vehicle restraint systems with respect to reducing the risk of placental abruption. Developing these models requires accurate material properties for tissues in the pregnant abdomen under dynamic loading conditions that can occur in crashes. A method has been developed for determining dynamic material properties of human soft tissues that combines results from uniaxial tensile tests, specimen-specific finite-element models based on laser scans that accurately capture non-uniform tissue-specimen geometry, and optimization techniques. The current study applies this method to characterizing material properties of placental tissue. For 21 placenta specimens tested at a strain rate of 12/s, the mean failure strain is 0.472+/-0.097 and the mean failure stress is 34.80+/-12.62 kPa. A first-order Ogden material model with ground-state shear modulus (mu) of 23.97+/-5.52 kPa and exponent (alpha(1)) of 3.66+/-1.90 best fits the test results. The new method provides a nearly 40% error reduction (p<0.001) compared to traditional curve-fitting methods by considering detailed specimen geometry, loading conditions, and dynamic effects from high-speed loading. The proposed method can be applied to determine mechanical properties of other soft biological tissues.

  15. An Axial-Torsional, Thermomechanical Fatigue Testing Technique

    NASA Technical Reports Server (NTRS)

    Kalluri, Sreeramesh; Bonacuse, Peter J.

    1995-01-01

    A technique for conducting strain-controlled, thermomechanical, axial-torsional fatigue tests on thin-walled tubular specimens was developed. Three waveforms of loading, namely, the axial strain waveform, the engineering shear strain waveform, and the temperature waveform were required in these tests. The phasing relationships between the mechanical strain waveforms and the temperature and axial strain waveforms were used to define a set of four axial-torsional, thermomechanical fatigue (AT-TMF) tests. Real-time test control (3 channels) and data acquisition (a minimum of 7 channels) were performed with a software program written in C language and executed on a personal computer. The AT-TMF testing technique was used to investigate the axial-torsional thermomechanical fatigue behavior of a cobalt-base superalloy, Haynes 188. The maximum and minimum temperatures selected for the AT-TMF tests were 760 and 316 C, respectively. Details of the testing system, calibration of the dynamic temperature profile of the thin-walled tubular specimen, thermal strain compensation technique, and test control and data acquisition schemes, are reported. The isothermal, axial, torsional, and in- and out-of-phase axial-torsional fatigue behaviors of Haynes 188 at 316 and 760 C were characterized in previous investigations. The cyclic deformation and fatigue behaviors of Haynes 188 in AT-TMF tests are compared to the previously reported isothermal axial-torsional behavior of this superalloy at the maximum and minimum temperatures.

  16. Mechanical behavior of Kenaf/Epoxy corrugated sandwich structures

    NASA Astrophysics Data System (ADS)

    Bakhori, S.; Hassan, M. Z.; Daud, Y.; Sarip, S.; Rahman, N.; Ismail, Z.; Aziz, S. A.

    2015-12-01

    This study presents the response of kenaf/epoxy corrugated sandwich structure during quasi-static test. Force-displacements curves have been deducted to determine the deformation pattern and collapse behavior of the structure. Kenaf/epoxy sandwich structures skins fabricated by using hand layup technique and the corrugated core were moulded by using steel mould. Different thicknesses of corrugated core web with two sizes of kenaf fibers were used. The corrugated core is then bonded with the skins by using poly-epoxy resin and has been cut into different number of cells. The specimens then tested under tensile and compression at different constant speeds until the specimens fully crushed. Tensile tests data showed the structure can be considered brittle when it breaking point strain, ε less than 0.025. In compression test, the specimens fail due to dominated by stress concentration that initiated by prior cracks. Also, the specimens with more number of cells and thicker core web have higher strength and the ability to absorb higher energy.

  17. Effects of proof loads and combined mode loadings on fracture and flaw growth characteristics of aerospace alloys

    NASA Technical Reports Server (NTRS)

    Shah, R. C.

    1974-01-01

    This experimental program was undertaken to determine the effects of (1) combined tensile and bending loadings, (2) combined tensile and shear loadings, and (3) proof overloads on fracture and flaw growth characteristics of aerospace alloys. Tests were performed on four alloys: 2219-T87 aluminum, 5Al-2.5Sn (ELl) titanium, 6Al-4V beta STA titanium and high strength 4340 steel. Tests were conducted in room air, gaseous nitrogen at -200F (144K), liquid nitrogen and liquid hydrogen. Flat center cracked and surface flawed specimens, cracked tube specimens, circumferentially notched round bar and surface flawed cylindrical specimens were tested. The three-dimensional photoelastic technique of stress freezing and slicing was used to determine stress intensity factors for surface flawed cylindrical specimens subjected to tension or torsion. Results showed that proof load/temperature histories used in the tests have a small beneficial effect or no effect on subsequent fracture strength and flaw growth rates.

  18. The effect of the air-blowing step on the technique sensitivity of four different adhesive systems.

    PubMed

    Spreafico, Diego; Semeraro, Stefano; Mezzanzanica, Dario; Re, Dino; Gagliani, Massimo; Tanaka, Toru; Sano, Hidehiko; Sidhu, Sharanbir K

    2006-03-01

    To evaluate the technique sensitivity of four different adhesive systems using different air-blowing pressure. Four adhesive systems were employed: Clearfil SE Bond [SE] (Kuraray, Japan), G-Bond [GB] (GC Corporation, Japan), Adper Prompt L-Pop [LP] (3M ESPE, USA) and an experimental adhesive, SSB-200 [SSB] (Kuraray, Japan). Twenty-four extracted molars were used. After grinding the coronal enamel surface, the teeth were divided into two equal groups. The first group's teeth were randomly assigned for bonding with the different adhesives using gentle air-blowing (g). For the teeth of the second group, the four adhesive systems were applied using strong air-blowing (s). After storage overnight in 37 degrees C water, the bonded specimens were sectioned into sticks (1 mm x 1 mm wide), which were subjected to microtensile bond strength testing (microTBS) at a crosshead speed of 1 mm/min. The load at failure of each specimen was recorded and the data were analyzed by one-way ANOVA and Tukey HSD tests. The surfaces of the fractured specimens were observed using SEM to determine the failure mode. The results of the microTBS test showed that the highest bond strengths tended to be with SE for both gentle and strong air-blowing, and the significantly lowest for SSB with strong air streaming. Comparing the two techniques, significant differences were noted only for SSB-200 (P < 0.05). For each material, the SEM evaluation did not show distinct differences in the nature of the fractures between the two techniques, except for SSB-200. The adhesives tested are not technique sensitive, except SSB-200, with regards to the air-blowing step.

  19. Environment-Assisted Cracking in Custom 465 Stainless Steel

    NASA Astrophysics Data System (ADS)

    Lee, E. U.; Goswami, R.; Jones, M.; Vasudevan, A. K.

    2011-02-01

    The influence of cold work and aging on the environment-assisted cracking (EAC) behavior and mechanical properties of Custom 465 stainless steel (SS) was studied. Four sets of specimens were made and tested. All specimens were initially solution annealed, rapidly cooled, and refrigerated (SAR condition). The first specimen set was steel in the SAR condition. The second specimen set was aged to the H1000 condition. The third specimen set was 60 pct cold worked, and the fourth specimen set was 60 pct cold worked and aged at temperatures ranging from 755 K to 825 K (482 °C to 552 °C) for 4 hours in air. The specimens were subsequently subjected to EAC and mechanical testing. The EAC testing was conducted, using the rising step load (RSL) technique, in aqueous solutions of NaCl of pH 7.3 with concentrations ranging from 0.0035 to 3.5 pct at room temperature. The microstructure, dislocation substructure, and crack paths, resulting from the cold work, aging, or subsequent EAC testing, were examined by optical microscopy, transmission electron microscopy (TEM), and scanning electron microscopy (SEM). The aging of the cold-worked specimens induced carbide precipitation within the martensite lath, but not at the lath or packet boundaries. In the aged specimens, as aging temperature rose, the threshold stress intensity for EAC (KIEAC), elongation, and fracture toughness increased, but the strength and hardness decreased. The KIEAC also decreased with increasing yield strength and NaCl concentration. In the SAR and H1000 specimens, the EAC propagated along the prior austenite grain boundary, while in the cold-worked and cold-worked and aged specimens, the EAC propagated along the martensite lath, and its packet and prior austenite grain boundaries. The controlling mechanism for the observed EAC was identified to be hydrogen embrittlement.

  20. Identification of Mycobacterium tuberculosis in Clinical Specimens of Patients Suspected of Having Extrapulmonary Tuberculosis by Application of Nested PCR on Five Different Genes

    PubMed Central

    Khosravi, Azar D.; Alami, Ameneh; Meghdadi, Hossein; Hosseini, Atta A.

    2017-01-01

    Definitive and rapid diagnosis of extrapulmonary tuberculosis (EPTB) is challenging since conventional techniques have limitations due to the paucibacillary nature of the disease. To increase the sensitivity of detection of Mycobacterium tuberculosis (MTB) in EPTB specimens, we performed a nested PCR assay targeting several genes of MTB on EPTB specimens. A total of 100 clinical specimens from suspected cases of EPTB were processed. Standard staining for acid fast bacilli (AFB) was performed as the preliminary screening test. Extracted DNAs from specimens were subjected to Nested PCR technique for the detection of five different MTB target genes of IS6110, IS1081, hsp65kd, mbp64, and mtp40. On performing AFB staining, only 13% of specimens were positive, of which ascites fluid (33.3%), followed by pleural effusion (30.8%) showed the greatest AFB positivity rate. We demonstrated slight improvement in yields in lymph node which comprised the majority of specimens in this study, by employing PCR targeted to IS6110- and hsp65-genes in comparison to AFB staining. However, the yields in ascites fluid and pleural effusion were not substantially improved by PCR, but those from bone and wound were, as in nested PCR employing either gene, the same positivity rate were obtained for ascites fluid (33.3%), while for pleural effusion specimens only IS1081 based PCR showed identical positivity rate with AFB stain (30.8%). The results for bone and wound specimens, however, demonstrated an improved yield mainly by employing IS1081 gene. Here, we report higher detection rate of EPTB in clinical specimens using five different targeted MTB genes. This nested PCR approach facilitates the comparison and the selection of the most frequently detected genes. Of course this study demonstrated the priority of IS1081 followed by mtp40 and IS6110, among the five tested genes and indicates the effectiveness of any of the three genes in the design of an efficient nested-PCR test that facilitates an early diagnosis of paucibacillary EPTB cases, which are difficult to diagnose with the available standard. PMID:28144587

  1. Identification of Mycobacterium tuberculosis in Clinical Specimens of Patients Suspected of Having Extrapulmonary Tuberculosis by Application of Nested PCR on Five Different Genes.

    PubMed

    Khosravi, Azar D; Alami, Ameneh; Meghdadi, Hossein; Hosseini, Atta A

    2017-01-01

    Definitive and rapid diagnosis of extrapulmonary tuberculosis (EPTB) is challenging since conventional techniques have limitations due to the paucibacillary nature of the disease. To increase the sensitivity of detection of Mycobacterium tuberculosis (MTB) in EPTB specimens, we performed a nested PCR assay targeting several genes of MTB on EPTB specimens. A total of 100 clinical specimens from suspected cases of EPTB were processed. Standard staining for acid fast bacilli (AFB) was performed as the preliminary screening test. Extracted DNAs from specimens were subjected to Nested PCR technique for the detection of five different MTB target genes of IS6110, IS1081, hsp65kd, mbp64 , and mtp40 . On performing AFB staining, only 13% of specimens were positive, of which ascites fluid (33.3%), followed by pleural effusion (30.8%) showed the greatest AFB positivity rate. We demonstrated slight improvement in yields in lymph node which comprised the majority of specimens in this study, by employing PCR targeted to IS6110 - and hsp65-genes in comparison to AFB staining. However, the yields in ascites fluid and pleural effusion were not substantially improved by PCR, but those from bone and wound were, as in nested PCR employing either gene, the same positivity rate were obtained for ascites fluid (33.3%), while for pleural effusion specimens only IS1081 based PCR showed identical positivity rate with AFB stain (30.8%). The results for bone and wound specimens, however, demonstrated an improved yield mainly by employing IS1081 gene. Here, we report higher detection rate of EPTB in clinical specimens using five different targeted MTB genes. This nested PCR approach facilitates the comparison and the selection of the most frequently detected genes. Of course this study demonstrated the priority of IS1081 followed by mtp40 and IS6110 , among the five tested genes and indicates the effectiveness of any of the three genes in the design of an efficient nested-PCR test that facilitates an early diagnosis of paucibacillary EPTB cases, which are difficult to diagnose with the available standard.

  2. Thermoluminescence of Antarctic meteorites: A rapid screening technique for terrestrial age estimation, pairing studies and identification of specimens with unusual prefall histories

    NASA Technical Reports Server (NTRS)

    Sutton, S. R.; Walker, R. M.

    1986-01-01

    Thermoluminescence (TL) is a promising technique for rapid screening of the large numbers of Antarctic meteorites, permitting identification of interesting specimens that can then be studied in detail by other, more definite techniques. Specifically, TL permits determination of rough terrestrial age, identification of potential paired groups and location of specimens with unusual pre-fall histories. Meteorites with long terrestrial ages are particularly valuable for studying transport and weathering mechanisms. Pairing studies are possible because TL variations among meteorites are large compared to variations within individual objects, especially for natural TL. Available TL data for several L3 fragments, three of which were paired by other techniques, are presented as an example of the use of TL parameters in pairing studies. Additional TL measurements, specifically a blind test, are recommended to satisfactorily establish the reliability of this pairing property. The TL measurements also identify fragments with unusual pre-fall histories, such an near-Sun orbits.

  3. Characterization of fatigue crack initiation and propagation in Ti-6Al-4V with electrical potential drop technique

    NASA Technical Reports Server (NTRS)

    Kalluri, Sreeramesh; Telesman, Jack

    1988-01-01

    Electrical potential methods have been used in the past primarily to monitor crack length in long crack specimens subjected to fatigue loading. An attempt was made to develop test procedures for monitoring the fatigue crack initiation and the growth of short fatigue cracks in a turbine disk alloy with the electrical potential drop technique (EPDT). In addition, the EPDT was also applied to monitor the fatigue crack growth in long crack specimens of the same alloy. The resolution of the EPDT for different specimen geometries was determined. Factors influencing the EPDT are identified and the applicability of EPDT in implementing damage tolerant design concepts for turbine disk materials is discussed. The experimental procedure adopted and the results obtained is discussed. No substantial differences were observed between the fatigue crack growth data of short and long crack specimens.

  4. Application of neural networks in the acousto-ultrasonic evaluation of metal-matrix composite specimens

    NASA Technical Reports Server (NTRS)

    Cios, Krzysztof J.; Tjia, Robert E.; Vary, Alex; Kautz, Harold E.

    1992-01-01

    Acousto-ultrasonics (AU) is a nondestructive evaluation (NDE) technique that was devised for the testing of various types of composite materials. A study has been done to determine how effectively the AU technique may be applied to metal-matrix composites (MMCs). The authors use the results and data obtained from that study and apply neural networks to them, particularly in the assessment of mechanical property variations of a specimen from AU measurements. It is assumed that there is no information concerning the important features of the AU signal which relate to the mechanical properties of the specimen. Minimally processed AU measurements are used while relying on the network's ability to extract the significant features of the signal.

  5. Acoustic levitation technique for containerless processing at high temperatures in space

    NASA Technical Reports Server (NTRS)

    Rey, Charles A.; Merkley, Dennis R.; Hammarlund, Gregory R.; Danley, Thomas J.

    1988-01-01

    High temperature processing of a small specimen without a container has been demonstrated in a set of experiments using an acoustic levitation furnace in the microgravity of space. This processing technique includes the positioning, heating, melting, cooling, and solidification of a material supported without physical contact with container or other surface. The specimen is supported in a potential energy well, created by an acoustic field, which is sufficiently strong to position the specimen in the microgravity environment of space. This containerless processing apparatus has been successfully tested on the Space Shuttle during the STS-61A mission. In that experiment, three samples wer successfully levitated and processed at temperatures from 600 to 1500 C. Experiment data and results are presented.

  6. Bithermal fatigue: A simplified alternative to thermomechanical fatigue

    NASA Technical Reports Server (NTRS)

    Verrilli, Michael J.

    1988-01-01

    A bithermal fatigue test technique was proposed as a simplified alternative to the thermomechanical fatigue test. Both the thermomechanical cycle and the bithermal technique can be used to study nonisothermal fatigue behavior. The difference between the two cycles is that in a conventional thermomechanical fatigue cycle the temperature is continuously varied concurrently with the applied mechanical strains, but in the bithermal fatigue cycle the specimen is held at zero load during the temperature excursions and all the loads are applied at the two extreme temperatures of the cycle. Experimentally, the bithermal fatigue test technique offers advantages such as ease in synchronizing the temperature and mechanical strain waveforms, in minimizing temperature gradients in the specimen gauge length, and in reducing and interpreting thermal fatigue such as the influence of alternate high and low temperatures on the cyclic stress-strain response characteristics, the effects of thermal state, and the possibility of introducing high- and low-temperature deformation mechanisms within the same cycle. The bithermal technique was used to study nonisothermal fatigue behavior of alloys such as single-crystal PWA 1480, single-crystal Rene N4, cast B1900+Hf, and wrought Haynes 188.

  7. Effects of silicon coating on bond strength of two different titanium ceramic to titanium.

    PubMed

    Ozcan, Isil; Uysal, Hakan

    2005-08-01

    This study investigated the effect of silicon coating (SiO2) by magnetron sputtering on bond strength of two different titanium ceramics to titanium. Sixty cast titanium specimens were prepared following the protocol ISO 9693. Titanium specimens were divided into two test and control groups with 15 specimens in each. Test groups were silicon coated by the magnetron sputtering technique. Two titanium ceramics (Triceram and Duceratin) were applied on both test (coated) and control (uncoated) metal specimens. The titanium-ceramic specimens were subjected to a three point flexural test. The groups were compared for their bond strength. SEM and SEM/EDS analyses were performed on the delaminated titanium surfaces to ascertain bond failure. The mean bond strength of Ti-Duceratin, Ti-Triceram, Si-coated Ti-Duceratin and Si-coated Ti-Triceram were 17.22+/-2.43, 23.31+/-3.18, 23.21+/-3.81 and 24.91+/-3.70 MPa, respectively. While the improvement in bond strength was 30% for Duceratin, it was statistically insignificant for Triceram. An adhesive mode of failure was observed in the Duceratin control group. In the silicoated Duceratin specimen, the bonded ceramic boundaries were wider but less than in the silicoated Triceram specimen. In the coated Triceram specimen, the ceramic retained areas were frequent and the failure mode was generally cohesive. Silicon coating was significantly effective in both preventing titanium oxide layer formation and in improving bond strength for Duceratin. However, it was of less value for Triceram.

  8. An Evaluation of the Service Failure of Aluminum Nose Cones Using Four Test Techniques.

    DTIC Science & Technology

    1987-03-01

    13 LIST OF ILLUSTRATIONS 1. Schematic of nose cone. 14 2. Subsize Charpy specimen. 15 3. Simulation test fixture. 16 4. Force displacement plot from...Figure 1. Schematic of nose cone. 14 LD 0.06 03-a 0.30L IL 1.602 Figure 2. Subsize Charpy specimen. i5 RAM DISPLACEMENT COLLART WV Ualz APPLIED FORCE...between threaded and tapered regions. In all, four measurements were made on each nose cone. The two material property measurements were made using Charpy

  9. Development of a multi-cycle shear-compression testing for the modeling of severe plastic deformation

    NASA Astrophysics Data System (ADS)

    Pesin, A.; Pustovoytov, D.; Lokotunina, N.

    2017-12-01

    The mechanism of severe plastic deformation comes from very significant shear strain. Shear-compression testing of materials is complicated by the fact that a state of large equivalent strain with dominant shear strain is not easily achievable. This paper presents the novel technique of laboratory simulation of severe plastic deformation by multi-cycle shear-compression testing at room temperature with equivalent strain e=1…5. The specimen consisted of a parallelepiped having an inclined gauge section created by two diametrically opposed semi-circular slots which were machined at 45°. Height of the specimen was 50 mm, section dimensions were 25×25 mm, gauge thickness was 5.0 mm and gauge width was 6.0 mm. The specimen provided dominant shear strain in an inclined gauge-section. The level of shear strain and equivalent strain was controlled through adjustment of the height reduction of the specimen, load application direction and number of cycles of shear-compression. Aluminium alloy Al-6.2Mg-0.7Mn was used as a material for specimen. FE simulation and analysis of the stress-strain state were performed. The microstructure of the specimen after multi-cycle shear-compression testing with equivalent strain e=1…5 was examined by optical and scanning electron microscope.

  10. Advantages and disadvantages of technologies for HER2 testing in breast cancer specimens.

    PubMed

    Furrer, Daniela; Sanschagrin, François; Jacob, Simon; Diorio, Caroline

    2015-11-01

    Human epidermal growth factor receptor 2 (HER2) plays a central role as a prognostic and predictive marker in breast cancer specimens. Reliable HER2 evaluation is central to determine the eligibility of patients with breast cancer to targeted anti-HER2 therapies such as trastuzumab and lapatinib. Presently, several methods exist for the determination of HER2 status at different levels (protein, RNA, and DNA level). In this review, we discuss the main advantages and disadvantages of the techniques developed so far for the evaluation of HER2 status in breast cancer specimens. Each technique has its own advantages and disadvantages. It is therefore not surprising that no consensus has been reached so far on which technique is the best for the determination of HER2 status. Currently, emphasis must be put on standardization of procedures, internal and external quality control assessment, and competency evaluation of already existing methods to ensure accurate, reliable, and clinically meaningful test results. Development of new robust and accurate diagnostic assays should also be encouraged. In addition, large clinical trials are warranted to identify the technique that most reliably predicts a positive response to anti-HER2 drugs. Copyright© by the American Society for Clinical Pathology.

  11. Repeatability and Reproducibility of Compression Strength Measurements Conducted According to ASTM E9

    NASA Technical Reports Server (NTRS)

    Luecke, William E.; Ma, Li; Graham, Stephen M.; Adler, Matthew A.

    2010-01-01

    Ten commercial laboratories participated in an interlaboratory study to establish the repeatability and reproducibility of compression strength tests conducted according to ASTM International Standard Test Method E9. The test employed a cylindrical aluminum AA2024-T351 test specimen. Participants measured elastic modulus and 0.2 % offset yield strength, YS(0.2 % offset), using an extensometer attached to the specimen. The repeatability and reproducibility of the yield strength measurement, expressed as coefficient of variations were cv(sub r)= 0.011 and cv(sub R)= 0.020 The reproducibility of the test across the laboratories was among the best that has been reported for uniaxial tests. The reported data indicated that using diametrically opposed extensometers, instead of a single extensometer doubled the precision of the test method. Laboratories that did not lubricate the ends of the specimen measured yield stresses and elastic moduli that were smaller than those measured in laboratories that lubricated the specimen ends. A finite element analysis of the test specimen deformation for frictionless and perfect friction could not explain the discrepancy, however. The modulus measured from stress-strain data were reanalyzed using a technique that finds the optimal fit range, and applies several quality checks to the data. The error in modulus measurements from stress-strain curves generally increased as the fit range decreased to less than 40 % of the stress range.

  12. Advances in Moire interferometry for thermal response of composites

    NASA Technical Reports Server (NTRS)

    Brooks, E. W., Jr.; Herakovich, C. T.; Post, D.; Hyer, M. W.

    1982-01-01

    An experimental technique for the precise measurement of the thermal response of both sides of a laminated composite coupon specimen uses Moire interferometry with fringe multiplication which yields a sensitivity of 833 nm (32.8 micro in.) per fringe. The reference gratings used are virtual gratings and are formed by partially mirrorized glass prisms in close proximity to the specimen. Results are compared with both results obtained from tests which used Moire interferometry on one side of composite laminates, and with those predicted by classical lamination theory. The technique is shown to be capable of producing the sensitivity and accuracy necessary to measure a wide range of thermal responses and to detect small side to side variations in the measured response. Tests were conducted on four laminate configurations of T300/5208 graphite epoxy over a temperature range of 297 K (75 F) to 422 K (300 F). The technique presented allows for the generation of reference gratings for temperature regimes well outside that used in these tests.

  13. Shear bond strength comparison between conventional porcelain fused to metal and new functionally graded dental restorations after thermal-mechanical cycling.

    PubMed

    Henriques, B; Gonçalves, S; Soares, D; Silva, F S

    2012-09-01

    The aim of this study was to evaluate the effect of thermo-mechanical cycling on the metal-ceramic bond strength of conventional porcelain fused to metal restorations (PFM) and new functionally graded metal-ceramic dental restorations (FGMR). Two types of specimens were produced: PFM and FGMR specimens. PFM specimens were produced by conventional PFM technique. FGMR specimens were hot pressed and prepared with a metal/ceramic composite interlayer (50 M, vol%) at the metal-ceramic interface. They were manufactured and standardized in cylindrical format and then submitted to thermal (3000, 6000 and 12,000 cycles; between 5 °C and 60 °C; dwell time: 30s) and mechanical (25,000, 50,000 and 100,000 cycles under a load of 50 N; 1.6 Hz) cycling. The shear bond strength tests were performed in a universal testing machine (crosshead speed: 0.5mm/min), using a special device to concentrate the tension at the metal-ceramic interface and the load was applied until fracture. The metal-ceramic interfaces were examined with SEM/EDS prior to and after shear tests. The Young's modulus and hardness were measured across the interfaces of both types of specimens using nanoindentation tests. Data was analyzed with Shapiro-Wilk test to test the assumption of normality. The 2-way ANOVA was used to compare shear bond strength results (p<0.05). FGMR specimens showed significantly (p<0.001) higher shear bond strength results than PFM specimens, irrespective of fatigue conditions. Fatigue conditions significantly (p<0.05) affected the shear bond strength results. The analysis of surface fracture revealed adhesive fracture type for PFM specimens and mixed fracture type for FGMR specimens. Nanoindentation tests showed differences in mechanical properties measured across the metal-ceramic interface for the two types of specimens, namely Young's Modulus and hardness. This study showed significantly better performance of the new functionally graded restorations relative to conventional PFM restorations, under fatigue testing conditions and for the materials tested. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Development of a small specimen test machine to evaluate irradiation embrittlement of fusion reactor materials

    NASA Astrophysics Data System (ADS)

    Ishii, T.; Ohmi, M.; Saito, J.; Hoshiya, T.; Ooka, N.; Jitsukawa, S.; Eto, M.

    2000-12-01

    Small specimen test techniques (SSTT) are essential to use an accelerator-driven deuterium-lithium stripping reaction neutron source for the study of fusion reactor materials because of the limitation of the available irradiation volume. A remote-controlled small punch (SP) test machine was developed at the hot laboratory of the Japan Materials Testing Reactor (JMTR) in the Japan Atomic Energy Research Institute (JAERI). This report describes the SP test method and machine for use in a hot cell, and test results on irradiated ferritic steels. The specimen was either a coupon 10×10×0.25 mm 3 or a TEM disk 3 mm in diameter by 0.25 mm in thickness. Tests can be performed at temperatures ranging from 93 to 1123 K in a vacuum or in an inert gas environment. The ductile to brittle transition temperature of the irradiated ferritic steel as determined by the SP test is also evaluated.

  15. The Effects of Fiber Orientation and Adhesives on Tensile Properties of Carbon Fiber Reinforced Polymer Matrix Composite with Embedded Nickel-Titanium Shape Memory Alloys

    NASA Technical Reports Server (NTRS)

    Quade, Derek J.; Jana, Sadhan C.; Morscher, Gregory N.; Kannan, Manigandan; McCorkle, Linda S.

    2017-01-01

    Nickel-titanium (NiTi) shape memory alloy (SMA) sections were embedded within carbon fiber reinforced polymer matrix composite (CFRPPMC) laminates and their tensile properties were evaluated with simultaneous monitoring of modal acoustic emissions. The test specimens were fabricated in three different layup configurations and two different thin film adhesives were applied to bond the SMA with the PMC. A trio of acoustic sensors were attached to the specimens during tensile testing to monitor the modal acoustic emission (AE) as the materials experienced mechanical failure. The values of ultimate tensile strengths, strains, and moduli were obtained. Cumulative AE energy of events and specimen failure location were determined. In conjunction, optical and scanning electron microscopy techniques were used to examine the break areas of the specimens. The analysis of AE data revealed failure locations within the specimens which were validated from the microscopic images. The placement of 90 deg plies in the outer ply gave the strongest acoustic signals during break as well as the cleanest break of the samples tested. Overlapping 0 deg ply layers surrounding the SMA was found to be the best scenario to prevent failure of the specimen itself.

  16. Is the Dresden technique a mechanical design of choice suitable for the repair of middle third Achilles tendon ruptures? A biomechanical study.

    PubMed

    de la Fuente, C; Carreño-Zillmann, G; Marambio, H; Henríquez, H

    2016-01-01

    To compare the mechanical failure of the Dresden technique for Achilles tendon repair with the double modified Kessler technique controlled repair technique. The maximum resistance of the two repair techniques are also compared. A total of 30 Achilles tendon ruptures in bovine specimens were repaired with an Ethibond(®) suture to 4.5cm from the calcaneal insertion. Each rupture was randomly distributed into one of two surgical groups. After repair, each specimen was subjected to a maximum traction test. The mechanical failure (tendon, suture, or knot) rates (proportions) were compared using the exact Fisher test (α=.05), and the maximum resistances using the Student t test (α=.05). There was a difference in the proportions of mechanical failures, with the most frequent being a tendon tear in the Dresden technique, and a rupture of the suture in the Kessler technique. The repair using the Dresden technique performed in the open mode, compared to the Kessler technique, has a more suitable mechanical design for the repair of middle third Achilles tendon ruptures on developing a higher tensile resistance in 58.7%. However, its most common mechanical failure was a tendon tear, which due to inappropriate loads could lead to lengthening of the Achilles tendon. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. 1000541

    NASA Image and Video Library

    2010-04-13

    TATHAN COFFEE (EM10 MATERIALS TEST ENGINEER, JACOBS ESTS GROUP/JTI) ADJUSTS A UNIQUE MECHANICAL TEST SETUP THAT MEASURES STRAIN ON A SINGLE SAMPLE, USING TWO DIFFERENT TECHNIQUES AT THE SAME TIME. THE TEST FIXTURE HOLDS A SPECIMEN THAT REPRESENTS A LIQUID OXYGEN (LOX) BEARING FROM THE J2-X ENGINE

  18. High-Speed Photographic Study of Wave Propagation and Impact Damage in Fused Silica and AlON Using the Edge-On Impact (EOI) Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strassburger, E.; Patel, P.; McCauley, J. W.

    An Edge-on Impact (EOI) technique, developed at the Ernst-Mach-Institute (EMI), coupled with a Cranz-Schardin high-speed camera, has been successfully utilized to visualize dynamic fracture in many brittle materials. In a typical test, the projectile strikes one edge of a specimen and damage formation and fracture propagation is recorded during the first 20 {mu}s after impact. In the present study, stress waves and damage propagation in fused silica and AlON were examined by means of two modified Edge-on Impact arrangements. In one arrangement, fracture propagation was observed simultaneously in side and top views of the specimens by means of two Cranz-Schardinmore » cameras. In another arrangement, the photographic technique was modified by placing the specimen between crossed polarizers and using the photo-elastic effect to visualize the stress waves. Pairs of impact tests at approximately equivalent velocities were carried out in transmitted plane (shadowgraphs) and crossed polarized light.« less

  19. Creep rupture testing of carbon fiber-reinforced epoxy composites

    NASA Astrophysics Data System (ADS)

    Burton, Kathryn Anne

    Carbon fiber is becoming more prevalent in everyday life. As such, it is necessary to have a thorough understanding of, not solely general mechanical properties, but of long-term material behavior. Creep rupture testing of carbon fiber is very difficult due to high strength and low strain to rupture properties. Past efforts have included testing upon strands, single tows and overwrapped pressure vessels. In this study, 1 inch wide, [0°/90°]s laminated composite specimens were constructed from fabric supplied by T.D. Williamson Inc. Specimen fabrication methods and gripping techniques were investigated and a method was developed to collect long term creep rupture behavior data. An Instron 1321 servo-hydraulic material testing machine was used to execute static strength and short term creep rupture tests. A hanging dead-weight apparatus was designed to perform long-term creep rupture testing. The testing apparatus, specimens, and specimen grips functioned well. Collected data exhibited a power law distribution and therefore, a linear trend upon a log strength-log time plot. Statistical analysis indicated the material exhibited slow degradation behavior, similar to previous studies, and could maintain a 50 year carrying capacity at 62% of static strength, approximately 45.7 ksi.

  20. Development of remote welding techniques for in-pile IASCC capsules and evaluation of material integrity on capsules for long irradiation period

    NASA Astrophysics Data System (ADS)

    Shibata, A.; Nakano, J.; Ohmi, M.; Kawamata, K.; Nakagawa, T.; Tsukada, T.

    2012-03-01

    To simulate irradiation assisted stress corrosion cracking (IASCC) behavior by in-pile experiments, it is necessary to irradiate specimens up to a neutron fluence that is higher than the IASCC threshold fluence. Pre-irradiated specimens must be relocated from pre-irradiation capsules to in-pile capsules. Hence, a remote welding machine has been developed. And the integrity of capsule housing for a long term irradiation was evaluated by tensile tests in air and slow strain rate tests in water. Two type specimens were prepared. Specimens were obtained from the outer tubes of capsule irradiated to 1.0-3.9 × 1026 n/m2 (E > 1 MeV). And specimens were irradiated in a leaky capsule to 0.03-1.0 × 1026 n/m2. Elongation more than 15% in tensile test at 423 K was confirmed and no IGSCC fraction was shown in SSRT at 423 K which was estimated as temperature at the outer tubes of the capsule under irradiation.

  1. Surface temperature determination in surface analytic systems by infrared optical pyrometry

    NASA Technical Reports Server (NTRS)

    Wheeler, Donald R.; Jones, William R., Jr.; Pepper, Stephen V.

    1988-01-01

    An IR pyrometric technique for measuring the surface temperatures of metal specimens in an ultrahigh-vacuum analytic chamber is described and demonstrated. The experimental setup comprises a commercial IR microscope with a long-working-distance right-angle objective (focal spot diameter 1 mm at 53 cm), a metal-coated glass vacuum chamber with a Ta-mesh-covered quartz viewport, an Mo specimen stub with an internal heating element, and a Ta disk test specimen with a flat side coated with a high-emissivity graphite film. The results of an initial calibration test are presented graphically and briefly characterized. The measurement error at 450 C is found to be less than 10 C.

  2. Composite materials flown on the Long Duration Exposure Facility

    NASA Technical Reports Server (NTRS)

    George, Pete E.; Dursch, Harry W.; Pippin, H. Gary

    1995-01-01

    Organic composite test specimens were flown on several LDEF experiments. Both bare and coated composites were flown. Atomic oxygen eroded bare composite material, with the resins being recessed at a greater rate than the fibers. Selected coating techniques protected the composite substrate in each case. Tensile and optical properties are reported for numerous specimens. Fiberglass and metal matrix composites were also flown.

  3. DNA Extraction from Museum Specimens of Parasitic Hymenoptera

    PubMed Central

    Andersen, Jeremy C.; Mills, Nicholas J.

    2012-01-01

    At the same time that molecular researchers are improving techniques to extract DNA from museum specimens, this increased demand for access to museum specimens has created tension between the need to preserve specimens for maintaining collections and morphological research and the desire to conduct molecular analyses. To address these concerns, we examined the suitability of non-invasive DNA extraction techniques on three species of parasitic Hymenoptera (Braconidae), and test the effects of body size (parasitoid species), age (time since collection), and DNA concentration from each extract on the probability of amplifying meaningful fragments of two commonly used genetic loci. We found that age was a significant factor for determining the probability of success for sequencing both 28S and COI fragments. While the size of the braconid parasitoids significantly affected the total amount of extracted DNA, neither size nor DNA concentration were significant factors for the amplification of either gene region. We also tested several primer combinations of various lengths, but were unable to amplify fragments longer than ∼150 base pairs. These short fragments of 28S and COI were however sufficient for species identification, and for the discovery of within species genetic variation. PMID:23077493

  4. Photoelasticity and DIC as optical techniques for monitoring masonry specimens under mechanical loads

    NASA Astrophysics Data System (ADS)

    Colla, C.; Gabrielli, E.

    2017-01-01

    To evaluate the complex behaviour of masonry structures under mechanical loads, numerical models are developed and continuously implemented at diverse scales, whilst, from an experimental viewpoint, laboratory standard mechanical tests are usually carried out by instrumenting the specimens via traditional measuring devices. Extracted values collected in the few points where the tools were installed are assumed to represent the behaviour of the whole specimen but this may be quite optimistic or approximate. Optical monitoring techniques may help in overcoming some of these limitations by providing full-field visualization of mechanical parameters. Photoelasticity and the more recent DIC, employed to monitor masonry columns during compression tests are here presented and a lab case study is compared listing procedures, data acquisitions, advantages and limitations. It is shown that the information recorded by traditional measuring tools must be considered limited to the specific instrumented points. Instead, DIC in particular among the optical techniques, is proving both a very precise global and local picture of the masonry performance, opening new horizons towards a deeper knowledge of this complex construction material. The applicability of an innovative DIC procedure to cultural heritage constructions is also discussed.

  5. A stochastic visco-hyperelastic model of human placenta tissue for finite element crash simulations.

    PubMed

    Hu, Jingwen; Klinich, Kathleen D; Miller, Carl S; Rupp, Jonathan D; Nazmi, Giseli; Pearlman, Mark D; Schneider, Lawrence W

    2011-03-01

    Placental abruption is the most common cause of fetal deaths in motor-vehicle crashes, but studies on the mechanical properties of human placenta are rare. This study presents a new method of developing a stochastic visco-hyperelastic material model of human placenta tissue using a combination of uniaxial tensile testing, specimen-specific finite element (FE) modeling, and stochastic optimization techniques. In our previous study, uniaxial tensile tests of 21 placenta specimens have been performed using a strain rate of 12/s. In this study, additional uniaxial tensile tests were performed using strain rates of 1/s and 0.1/s on 25 placenta specimens. Response corridors for the three loading rates were developed based on the normalized data achieved by test reconstructions of each specimen using specimen-specific FE models. Material parameters of a visco-hyperelastic model and their associated standard deviations were tuned to match both the means and standard deviations of all three response corridors using a stochastic optimization method. The results show a very good agreement between the tested and simulated response corridors, indicating that stochastic analysis can improve estimation of variability in material model parameters. The proposed method can be applied to develop stochastic material models of other biological soft tissues.

  6. Observation of Intralaminar Cracking in the Edge Crack Torsion Specimen

    NASA Technical Reports Server (NTRS)

    Czabaj, Michael W.; Ratcliffe, James G.; Davidson, Barry D.

    2013-01-01

    The edge crack torsion (ECT) test is evaluated to determine its suitability for measuring fracture toughness associated with mode III delamination growth onset. A series of ECT specimens with preimplanted inserts with different lengths is tested and examined using nondestructive and destructive techniques. Ultrasonic inspection of all tested specimens reveals that delamination growth occurs at one interface ply beneath the intended midplane interface. Sectioning and optical microscopy suggest that the observed delamination growth results from coalescence of angled intralaminar matrix cracks that form and extend across the midplane plies. The relative orientation of these cracks is approximately 45 deg with respect to the midplane, suggesting their formation is caused by resolved principal tensile stresses arising due to the global mode-III shear loading. Examination of ECT specimens tested to loads below the level corresponding to delamination growth onset reveals that initiation of intralaminar cracking approximately coincides with the onset of nonlinearity in the specimen's force-displacement response. The existence of intralaminar cracking prior to delamination growth onset and the resulting delamination extension at an unintended interface render the ECT test, in its current form, unsuitable for characterization of mode III delamination growth onset. The broader implications of the mechanisms observed in this study are also discussed with respect to the current understanding of shear-driven delamination in tape-laminate composites.

  7. Numerical development of a new correlation between biaxial fracture strain and material fracture toughness for small punch test

    NASA Astrophysics Data System (ADS)

    Kumar, Pradeep; Dutta, B. K.; Chattopadhyay, J.

    2017-04-01

    The miniaturized specimens are used to determine mechanical properties of the materials, such as yield stress, ultimate stress, fracture toughness etc. Use of such specimens is essential whenever limited quantity of material is available for testing, such as aged/irradiated materials. The miniaturized small punch test (SPT) is a technique which is widely used to determine change in mechanical properties of the materials. Various empirical correlations are proposed in the literature to determine the value of fracture toughness (JIC) using this technique. bi-axial fracture strain is determined using SPT tests. This parameter is then used to determine JIC using available empirical correlations. The correlations between JIC and biaxial fracture strain quoted in the literature are based on experimental data acquired for large number of materials. There are number of such correlations available in the literature, which are generally not in agreement with each other. In the present work, an attempt has been made to determine the correlation between biaxial fracture strain (εqf) and crack initiation toughness (Ji) numerically. About one hundred materials are digitally generated by varying yield stress, ultimate stress, hardening coefficient and Gurson parameters. Such set of each material is then used to analyze a SPT specimen and a standard TPB specimen. Analysis of SPT specimen generated biaxial fracture strain (εqf) and analysis of TPB specimen generated value of Ji. A graph is then plotted between these two parameters for all the digitally generated materials. The best fit straight line determines the correlation. It has been also observed that it is possible to have variation in Ji for the same value of biaxial fracture strain (εqf) within a limit. Such variation in the value of Ji has been also ascertained using the graph. Experimental SPT data acquired earlier for three materials were then used to get Ji by using newly developed correlation. A reasonable comparison of calculated Ji with the values quoted in literature confirmed usefulness of the correlation.

  8. Evaluation of the fidelity of feature descriptor-based specimen tracking for automatic NDE data integration

    NASA Astrophysics Data System (ADS)

    Radkowski, Rafael; Holland, Stephen; Grandin, Robert

    2018-04-01

    This research addresses inspection location tracking in the field of nondestructive evaluation (NDE) using a computer vision technique to determine the position and orientation of typical NDE equipment in a test setup. The objective is the tracking accuracy for typical NDE equipment to facilitate automatic NDE data integration. Since the employed tracking technique relies on surface curvatures of an object of interest, the accuracy can be only experimentally determined. We work with flash-thermography and conducted an experiment in which we tracked a specimen and a thermography flash hood, measured the spatial relation between both, and used the relation as input to map thermography data onto a 3D model of the specimen. The results indicate an appropriate accuracy, however, unveiled calibration challenges.

  9. An Experimental Study of the Fracture Coalescence Behaviour of Brittle Sandstone Specimens Containing Three Fissures

    NASA Astrophysics Data System (ADS)

    Yang, S. Q.; Yang, D. S.; Jing, H. W.; Li, Y. H.; Wang, S. Y.

    2012-07-01

    To analyse the fracture coalescence behaviour of rock, rectangular prismatic sandstone specimens (80 × 160 × 30 mm in size) containing three fissures were tested under uniaxial compression. The strength and deformation behaviours of the specimens are first analysed by investigating the effects of the ligament angle β2 on the peak strength, peak strain and crack initiation stress of the specimens. To confirm the sequence of crack coalescence, a photographic monitoring technique is used throughout the entire period of deformation. Based on the results, the relationship between the real-time crack coalescence process and the axial stress-strain curve of brittle sandstone specimens is also developed, and this relationship can be used to evaluate the macroscopic deformation characteristics of pre-cracked rock. The equivalent strain evolution fields of the specimen, with α = β1 = 45° and β2 = 90°, are obtained using the digital image correlation technique and show good agreement with the experimental results of pre-cracked brittle sandstone. These experimental results are expected to improve the understanding of fracture mechanisms and be used in rock engineering with intermittent structures, such as deep underground excavated tunnels.

  10. Optimization of routine KRAS mutation PCR-based testing procedure for rational individualized first-line-targeted therapy selection in metastatic colorectal cancer.

    PubMed

    Chretien, Anne-Sophie; Harlé, Alexandre; Meyer-Lefebvre, Magali; Rouyer, Marie; Husson, Marie; Ramacci, Carole; Harter, Valentin; Genin, Pascal; Leroux, Agnès; Merlin, Jean-Louis

    2013-02-01

    KRAS mutation detection represents a crucial issue in metastatic colorectal cancer (mCRC). The optimization of KRAS mutation detection delay enabling rational prescription of first-line treatment in mCRC including anti-EGFR-targeted therapy requires robust and rapid molecular biology techniques. Routine analysis of mutations in codons 12 and 13 on 674 paraffin-embedded tissue specimens of mCRC has been performed for KRAS mutations detection using three molecular biology techniques, that is, high-resolution melting (HRM), polymerase chain reaction restriction fragment length polymorphism (PCR-RFLP), and allelic discrimination PCR (TaqMan PCR). Discordant cases were assessed with COBAS 4800 KRAS CE-IVD assay. Among the 674 tumor specimens, 1.5% (10/674) had excessive DNA degradation and could not be analyzed. KRAS mutations were detected in 38.0% (256/674) of the analysable specimens (82.4% in codon 12 and 17.6% in codon 13). Among 613 specimens in whom all three techniques were used, 12 (2.0%) cases of discordance between the three techniques were observed. 83.3% (10/12) of the discordances were due to PCR-RFLP as confirmed by COBAS 4800 retrospective analysis. The three techniques were statistically comparable (κ > 0.9; P < 0.001). From these results, optimization of the routine procedure consisted of proceeding to systematic KRAS detection using HRM and TaqMan and PCR-RFLP in case of discordance and allowed significant decrease in delays. The results showed an excellent correlation between the three techniques. Using HRM and TaqMan warrants high-quality and rapid-routine KRAS mutation detection in paraffin-embedded tumor specimens. The new procedure allowed a significant decrease in delays for reporting results, enabling rational prescription of first-line-targeted therapy in mCRC.

  11. NDE of PWA 1480 single crystal turbine blade material

    NASA Technical Reports Server (NTRS)

    Klima, Stanley J.; Orange, Thomas W.; Dreshfield, Robert L.

    1993-01-01

    Cantilever bending fatigue specimens were examined by fluorescent liquid penetrant and radioactive gas penetrant (Krypton) non-destructive evaluation (NDE) methods and tested. Specimens with cast, ground, or polished surface were evaluated to study the effect of surface condition on NDE and fatigue crack initiation. Fractographic and metallurgical analyses were performed to determine the nature of crack precursors. Preliminary results show that fatigue strength was lower for specimens with cast surfaces than for specimens with machined surfaces. The liquid penetrant and gas penetrant techniques both provided indications of a large population of defects on the cast surfaces. On ground or polished specimen surfaces, the gas penetrant appeared to estimate the actual number of voids more accurately than the liquid penetrant.

  12. Microstructural analysis of 800H steel exposed at test operation in HTHL by using FIB-SEM and HRTEM techniques

    NASA Astrophysics Data System (ADS)

    Marušáková, Daniela; Bublíková, Petra; Berka, Jan; Vávrovcová, Zuzana; Burda, Jaroslav

    2017-09-01

    To understand the degradation process of metal materials which are used in power engineering, appropriate evaluation procedure is necessary to ensure. In that order, the degradation of alloy 800H during the first period of test operation in High Temperature Helium Loop (HTHL) was tested. Experiment was carried out in atmosphere of pure technical helium with purity 4.6 containing only residual concentration of moisture up to 300 vppm. Parameters during the operation test were not constant, process was interrupted several times. The maximum temperature on specimens during this period was 750 °C, average temperature was 460 °C, gas pressure ranged from 3 to 6 MPa and gas flow from 3 to 9 gs-1. Total duration of the test was 264 h. After the exposure the degradation of specimens was investigated by Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM). Using the technique of Focused Ion Beam (FIB) integrated within SEM the transparent samples with quality surface parameters were obtained for TEM analysis. FIB technique in combination with High Resolution TEM ensured the guaranteed methodology of exposed sample preparation and precise description of changes in this kind of material.

  13. Micro/Nano-scale Strain Distribution Measurement from Sampling Moiré Fringes.

    PubMed

    Wang, Qinghua; Ri, Shien; Tsuda, Hiroshi

    2017-05-23

    This work describes the measurement procedure and principles of a sampling moiré technique for full-field micro/nano-scale deformation measurements. The developed technique can be performed in two ways: using the reconstructed multiplication moiré method or the spatial phase-shifting sampling moiré method. When the specimen grid pitch is around 2 pixels, 2-pixel sampling moiré fringes are generated to reconstruct a multiplication moiré pattern for a deformation measurement. Both the displacement and strain sensitivities are twice as high as in the traditional scanning moiré method in the same wide field of view. When the specimen grid pitch is around or greater than 3 pixels, multi-pixel sampling moiré fringes are generated, and a spatial phase-shifting technique is combined for a full-field deformation measurement. The strain measurement accuracy is significantly improved, and automatic batch measurement is easily achievable. Both methods can measure the two-dimensional (2D) strain distributions from a single-shot grid image without rotating the specimen or scanning lines, as in traditional moiré techniques. As examples, the 2D displacement and strain distributions, including the shear strains of two carbon fiber-reinforced plastic specimens, were measured in three-point bending tests. The proposed technique is expected to play an important role in the non-destructive quantitative evaluations of mechanical properties, crack occurrences, and residual stresses of a variety of materials.

  14. Molecular markers: Implications for cytopathology and specimen collection.

    PubMed

    VanderLaan, Paul A

    2015-08-01

    Cytologic specimens obtained through minimally invasive biopsy techniques are increasingly being used as principle diagnostic specimens for tumors arising in multiple sites. The number and scope of ancillary tests performed on these specimens have grown substantially over the past decade, including many molecular markers that not only can aid in formulating accurate and specific diagnoses but also can provide prognostic or therapeutic information to help direct clinical decisions. Thus, the cytopathologist needs to ensure that adequate material is collected and appropriately processed for the study of relevant molecular markers, many of which are specific to tumor site. This brief review covers considerations for effective cytologic specimen collection and processing to ensure diagnostic and testing success. In addition, a general overview is provided of molecular markers pertinent to tumors from a variety of sites. The recognition of these established and emerging molecular markers by cytopathologists is an important step toward realizing the promise of personalized medicine. © 2015 American Cancer Society.

  15. Mechanical characteristics of a tool steel layer deposited by using direct energy deposition

    NASA Astrophysics Data System (ADS)

    Baek, Gyeong Yun; Shin, Gwang Yong; Lee, Eun Mi; Shim, Do Sik; Lee, Ki Yong; Yoon, Hi-Seak; Kim, Myoung Ho

    2017-07-01

    This study focuses on the mechanical characteristics of layered tool steel deposited using direct energy deposition (DED) technology. In the DED technique, a laser beam bonds injected metal powder and a thin layer of substrate via melting. In this study, AISI D2 substrate was hardfaced with AISI H13 and M2 metal powders for mechanical testing. The mechanical and metallurgical characteristics of each specimen were investigated via microstructure observation and hardness, wear, and impact tests. The obtained characteristics were compared with those of heat-treated tool steel. The microstructures of the H13- and M2-deposited specimens show fine cellular-dendrite solidification structures due to melting and subsequent rapid cooling. Moreover, the cellular grains of the deposited M2 layer were smaller than those of the H13 structure. The hardness and wear resistance were most improved in the M2-deposited specimen, yet the H13-deposited specimen had higher fracture toughness than the M2-deposited specimen and heat-treated D2.

  16. Rapid and sensitive detection of enteroviruses in specimens from patients with aseptic meningitis.

    PubMed Central

    Yerly, S; Gervaix, A; Simonet, V; Caflisch, M; Perrin, L; Wunderli, W

    1996-01-01

    A 5-h PCR assay (Amplicor enterovirus test) was compared with viral culture for the detection of enteroviruses in cerebrospinal fluid. Of the cerebrospinal fluid specimens collected during a summer outbreak of aseptic meningitis, 34% were positive by viral culture whereas 66% were positive by the Amplicor PCR, suggesting that this technique improves the diagnosis of enteroviral meningitis. PMID:8748304

  17. Damage source identification of reinforced concrete structure using acoustic emission technique.

    PubMed

    Panjsetooni, Alireza; Bunnori, Norazura Muhamad; Vakili, Amir Hossein

    2013-01-01

    Acoustic emission (AE) technique is one of the nondestructive evaluation (NDE) techniques that have been considered as the prime candidate for structural health and damage monitoring in loaded structures. This technique was employed for investigation process of damage in reinforced concrete (RC) frame specimens. A number of reinforced concrete RC frames were tested under loading cycle and were simultaneously monitored using AE. The AE test data were analyzed using the AE source location analysis method. The results showed that AE technique is suitable to identify the sources location of damage in RC structures.

  18. Damage Source Identification of Reinforced Concrete Structure Using Acoustic Emission Technique

    PubMed Central

    Panjsetooni, Alireza; Bunnori, Norazura Muhamad; Vakili, Amir Hossein

    2013-01-01

    Acoustic emission (AE) technique is one of the nondestructive evaluation (NDE) techniques that have been considered as the prime candidate for structural health and damage monitoring in loaded structures. This technique was employed for investigation process of damage in reinforced concrete (RC) frame specimens. A number of reinforced concrete RC frames were tested under loading cycle and were simultaneously monitored using AE. The AE test data were analyzed using the AE source location analysis method. The results showed that AE technique is suitable to identify the sources location of damage in RC structures. PMID:23997681

  19. Benchmark cyclic plastic notch strain measurements

    NASA Technical Reports Server (NTRS)

    Sharpe, W. N., Jr.; Ward, M.

    1983-01-01

    Plastic strains at the roots of notched specimens of Inconel 718 subjected to tension-compression cycling at 650 C are reported. These strains were measured with a laser-based technique over a gage length of 0.1 mm and are intended to serve as 'benchmark' data for further development of experimental, analytical, and computational approaches. The specimens were 250 mm by 2.5 mm in the test section with double notches of 4.9 mm radius subjected to axial loading sufficient to cause yielding at the notch root on the tensile portion of the first cycle. The tests were run for 1000 cycles at 10 cpm or until cracks initiated at the notch root. The experimental techniques are described, and then representative data for the various load spectra are presented. All the data for each cycle of every test are available on floppy disks from NASA.

  20. Application of gamma-ray radiography and gravimetric measurements after accelerated corrosion tests of steel embedded in mortar

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duffó, Gustavo, E-mail: duffo@cnea.gov.ar; Consejo Nacional de Investigaciones Científicas y Técnicas; Universidad Nacional de San Martín, Av. Gral. Paz 1499, 1650 San Martín, Buenos Aires

    2015-08-15

    The accelerated corrosion by the impressed current technique is widely used in studies of concrete durability since it has the advantage that tests can be carried out within reasonable periods of time. In the present work the relationship between the applied current density and the resulting damage on the reinforcing steel, by applying optical microscopy, scanning electron microscopy, gamma-ray radiography and gravimetric measurements, was studied by means of the implementation of accelerated corrosion tests on reinforced mortar. The results show that the efficiency of the applied current is between 1 and 77%, regardless of the applied current density, the water/cementmore » ratio and the mortar cover depth of the specimens. The results show the applicability of the gamma-ray radiography technique to detect localized corrosion of steel rebars in laboratory specimens.« less

  1. OSM-Classic : An optical imaging technique for accurately determining strain

    NASA Astrophysics Data System (ADS)

    Aldrich, Daniel R.; Ayranci, Cagri; Nobes, David S.

    OSM-Classic is a program designed in MATLAB® to provide a method of accurately determining strain in a test sample using an optical imaging technique. Measuring strain for the mechanical characterization of materials is most commonly performed with extensometers, LVDT (linear variable differential transistors), and strain gauges; however, these strain measurement methods suffer from their fragile nature and it is not particularly easy to attach these devices to the material for testing. To alleviate these potential problems, an optical approach that does not require contact with the specimen can be implemented to measure the strain. OSM-Classic is a software that interrogates a series of images to determine elongation in a test sample and hence, strain of the specimen. It was designed to provide a graphical user interface that includes image processing with a dynamic region of interest. Additionally, the stain is calculated directly while providing active feedback during the processing.

  2. Microstructure-Sensitive Investigation of Fracture Using Acoustic Emission Coupled With Electron Microscopy

    NASA Technical Reports Server (NTRS)

    Wisner, Brian; Cabal, Mike; Vanniamparambiland, Prashanth A.; Leser, William; Hochhalter, Jacob; Kontsos, Antonios

    2015-01-01

    A novel technique using Scanning Electron Microscopy (SEM) in conjunction with Acoustic Emission (AE) monitoring is proposed to investigate microstructure-sensitive fatigue and fracture of metals. The coupling between quasi in situ microscopy with actual in situ nondestructive evaluation falls into the ICME framework and the idea of quantitative data-driven characterization of material behavior. To validate the use of AE monitoring inside the SEM chamber, Aluminum 2024-B sharp notch specimen were tested both inside and outside the microscope using a small scale mechanical testing device. Subsequently, the same type of specimen was tested inside the SEM chamber. Load data were correlated with both AE information and observations of microcracks around grain boundaries as well as secondary cracks, voids, and slip bands. The preliminary results are in excellent agreement with similar findings at the mesoscale. Extensions of the application of this novel technique are discussed.

  3. Biomechanical Comparison Study of Three Fixation Methods for Proximal Chevron Osteotomy of the First Metatarsal in Hallux Valgus.

    PubMed

    Kim, Jin Su; Cho, Hun Ki; Young, Ki Won; Kim, Ji Soo; Lee, Kyung Tai

    2017-12-01

    Fixation of proximal chevron metatarsal osteotomy has been accomplished using K-wires traditionally and with a locking plate recently. However, both methods have many disadvantages. Hence, we developed an intramedullary fixation technique using headless cannulated screws and conducted a biomechanical study to evaluate the superiority of the technique to K-wire and locking plate fixations. Proximal chevron metatarsal osteotomy was performed on 30 synthetic metatarsal models using three fixation techniques. Specimens in group I were fixated with K-wires (1.6 mm × 2) and in group II with headless cannulated screws (3.0 mm × 2) distally through the intramedullary canal. Specimens in group III were fixated with a locking X-shaped plate (1.3-mm thick) and screws (2.5 mm × 4). Eight metatarsal specimens were selected from each group for walking fatigue test. Bending stiffness and dorsal angulation were measured by 1,000 repetitions of a cantilever bending protocol in a plantar to dorsal direction. The remaining two samples from each group were subjected to 5 mm per minute axial loading to assess the maximal loading tolerance. All samples in group I failed walking fatigue test while group II and group III tolerated the walking fatigue test. Group II showed greater resistance to bending force and smaller dorsal angulation than group III ( p = 0.001). On the axial loading test, group I and group II demonstrated superior maximum tolerance to group III (54.8 N vs. 47.2 N vs. 28.3 N). Authors have demonstrated proximal chevron metatarsal osteotomy with intramedullary screw fixation provides superior biomechanical stability to locking plate and K-wire fixations. The new technique using intramedullary screw fixation can offer robust fixation and may lead to better outcomes in surgical treatment of hallux valgus.

  4. Scanning transmission ion micro-tomography (STIM-T) of biological specimens.

    PubMed

    Schwertner, Micheal; Sakellariou, Arthur; Reinert, Tilo; Butz, Tilman

    2006-05-01

    Computed tomography (CT) was applied to sets of Scanning Transmission Ion Microscopy (STIM) projections recorded at the LIPSION ion beam laboratory (Leipzig) in order to visualize the 3D-mass distribution in several specimens. Examples for a test structure (copper grid) and for biological specimens (cartilage cells, cygospore) are shown. Scanning Transmission Micro-Tomography (STIM-T) at a resolution of 260 nm was demonstrated for the first time. Sub-micron features of the Cu-grid specimen were verified by scanning electron microscopy. The ion energy loss measured during a STIM-T experiment is related to the mass density of the specimen. Typically, biological specimens can be analysed without staining. Only shock freezing and freeze-drying is required to preserve the ultra-structure of the specimen. The radiation damage to the specimen during the experiment can be neglected. This is an advantage compared to other techniques like X-ray micro-tomography. At present, the spatial resolution is limited by beam position fluctuations and specimen vibrations.

  5. Low friction and high strength of 316L stainless steel tubing for biomedical applications.

    PubMed

    Amanov, Auezhan; Lee, Soo-Wohn; Pyun, Young-Sik

    2017-02-01

    We propose herein a nondestructive surface modification technique called ultrasonic nanocrystalline surface modification (UNSM) to increase the strength and to improve the tribological performance of 316L stainless steel (SS) tubing. Nanocrystallization along nearly the complete tube thickness of 200μm was achieved by UNSM technique that was confirmed by electron backscatter diffraction (EBSD). Nano-hardness of the untreated and UNSM-treated specimens was measured using a nanoindentation. Results revealed that a substantial increase in hardness was obtained for the UNSM-treated specimen that may be attributed to the nanocrystallization and refined grains. Stress-strain behavior of the untreated and UNSM-treated specimens was assessed by a 3-point bending test. It was found that the UNSM-treated specimen exhibited a much higher strength than that of the untreated specimen. In addition, the tribological behavior of the untreated and UNSM-treated specimens with an outer diameter (OD) of 1.6mm and an inner diameter (ID) of 1.2mm was investigated using a cylinder-on-cylinder (crossed tubes of equal radius) tribo-tester against itself under dry conditions at ambient temperature. The friction coefficient and wear resistance of the UNSM-treated specimen were remarkably improved compared to that of the untreated specimen. The significant increase in hardness after UNSM treatment is responsible for the improved friction coefficient and wear resistance of the tubing. Thus, the UNSM technique was found to be beneficial to improving the mechanical and tribological properties of 316L SS tubing for various potential biomedical applications, in particular for coronary artery stents. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Use of an automated chromium reduction system for hydrogen isotope ratio analysis of physiological fluids applied to doubly labeled water analysis.

    PubMed

    Schoeller, D A; Colligan, A S; Shriver, T; Avak, H; Bartok-Olson, C

    2000-09-01

    The doubly labeled water method is commonly used to measure total energy expenditure in free-living subjects. The method, however, requires accurate and precise deuterium abundance determinations, which can be laborious. The aim of this study was to evaluate a fully automated, high-throughput, chromium reduction technique for the measurement of deuterium abundances in physiological fluids. The chromium technique was compared with an off-line zinc bomb reduction technique and also subjected to test-retest analysis. Analysis of international water standards demonstrated that the chromium technique was accurate and had a within-day precision of <1 per thousand. Addition of organic matter to water samples demonstrated that the technique was sensitive to interference at levels between 2 and 5 g l(-1). Physiological samples could be analyzed without this interference, plasma by 10000 Da exclusion filtration, saliva by sedimentation and urine by decolorizing with carbon black. Chromium reduction of urine specimens from doubly labeled water studies indicated no bias relative to zinc reduction with a mean difference in calculated energy expenditure of -0.2 +/- 3.9%. Blinded reanalysis of urine specimens from a second doubly labeled water study demonstrated a test-retest coefficient of variation of 4%. The chromium reduction method was found to be a rapid, accurate and precise method for the analysis of urine specimens from doubly labeled water. Copyright 2000 John Wiley & Sons, Ltd.

  7. i RadMat: A thermo-mechanical testing system for in situ high-energy X-ray characterization of radioactive specimens

    DOE PAGES

    Zhang, Xuan; Xu, Chi; Wang, Leyun; ...

    2017-01-27

    Here, we present an in situ Radiated Materials (iRadMat) experimental module designed to interface with a servo-hydraulic load frame for X-ray measurements at beamline 1-ID at the Advanced Photon Source. This new capability allows in situ studies of radioactive specimens subject to thermo-mechanical loading using a suite of high-energy X-ray scattering and imaging techniques. The iRadMat is a radiation-shielded vacuum heating system with the sample rotation-under-load capability. We describe the design features and performances of the iRadMat and present a dataset from a 300 °C uniaxial tensile test of a neutron-irradiated pure Fe specimen to demonstrate its capabilities.

  8. Measurement of damping of graphite epoxy materials

    NASA Technical Reports Server (NTRS)

    Crocker, M. J.

    1985-01-01

    The design of an experiment to measure the damping of a cylindrical graphite-epoxy specimen with a three point support and a knife edge support is described as well as equipment used in tests conducted to determine the influence of the support at the two ends of the specimen and to simulate an idealized free-free boundary condition at the two edges. A curve fitting technique is being used to process the frequency response data obtained. Experiments conducted on the thin plate specimen also reveal the influence of the end support condition on the damping ratio of the specimen. The damping ratio values measured for both specimens appear to be strongly influenced by the shape of the specimen and appear to depend on length and fiber orientation as well as the presence of discontinuities such as sharp bends, corners, and notches.

  9. Femtosecond laser machining for characterization of local mechanical properties of biomaterials: a case study on wood

    PubMed Central

    Jakob, Severin; Pfeifenberger, Manuel J.; Hohenwarter, Anton; Pippan, Reinhard

    2017-01-01

    Abstract The standard preparation technique for micro-sized samples is focused ion beam milling, most frequently using Ga+ ions. The main drawbacks are the required processing time and the possibility and risks of ion implantation. In contrast, ultrashort pulsed laser ablation can process any type of material with ideally negligible damage to the surrounding volume and provides 4 to 6 orders of magnitude higher ablation rates than the ion beam technique. In this work, a femtosecond laser was used to prepare wood samples from spruce for mechanical testing at the micrometre level. After optimization of the different laser parameters, tensile and compressive specimens were produced from microtomed radial-tangential and longitudinal-tangential sections. Additionally, laser-processed samples were exposed to an electron beam prior to testing to study possible beam damage. The specimens originating from these different preparation conditions were mechanically tested. Advantages and limitations of the femtosecond laser preparation technique and the deformation and fracture behaviour of the samples are discussed. The results prove that femtosecond laser processing is a fast and precise preparation technique, which enables the fabrication of pristine biological samples with dimensions at the microscale. PMID:28970867

  10. Femtosecond laser machining for characterization of local mechanical properties of biomaterials: a case study on wood

    NASA Astrophysics Data System (ADS)

    Jakob, Severin; Pfeifenberger, Manuel J.; Hohenwarter, Anton; Pippan, Reinhard

    2017-12-01

    The standard preparation technique for micro-sized samples is focused ion beam milling, most frequently using Ga+ ions. The main drawbacks are the required processing time and the possibility and risks of ion implantation. In contrast, ultrashort pulsed laser ablation can process any type of material with ideally negligible damage to the surrounding volume and provides 4 to 6 orders of magnitude higher ablation rates than the ion beam technique. In this work, a femtosecond laser was used to prepare wood samples from spruce for mechanical testing at the micrometre level. After optimization of the different laser parameters, tensile and compressive specimens were produced from microtomed radial-tangential and longitudinal-tangential sections. Additionally, laser-processed samples were exposed to an electron beam prior to testing to study possible beam damage. The specimens originating from these different preparation conditions were mechanically tested. Advantages and limitations of the femtosecond laser preparation technique and the deformation and fracture behaviour of the samples are discussed. The results prove that femtosecond laser processing is a fast and precise preparation technique, which enables the fabrication of pristine biological samples with dimensions at the microscale.

  11. Electric conductivity for laboratory and field monitoring of induced partial saturation (IPS) in sands

    NASA Astrophysics Data System (ADS)

    Kazemiroodsari, Hadi

    Liquefaction is loss of shear strength in fully saturated loose sands caused by build-up of excess pore water pressure, during moderate to large earthquakes, leading to catastrophic failures of structures. Currently used liquefaction mitigation measures are often costly and cannot be applied at sites with existing structures. An innovative, practical, and cost effective liquefaction mitigation technique titled "Induced Partial Saturation" (IPS) was developed by researchers at Northeastern University. The IPS technique is based on injection of sodium percarbonate solution into fully saturated liquefaction susceptible sand. Sodium percarbonate dissolves in water and breaks down into sodium and carbonate ions and hydrogen peroxide which generates oxygen gas bubbles. Oxygen gas bubbles become trapped in sand pores and therefore decrease the degree of saturation of the sand, increase the compressibility of the soil, thus reduce its potential for liquefaction. The implementation of IPS required the development and validation of a monitoring and evaluation technique that would help ensure that the sands are indeed partially saturated. This dissertation focuses on this aspect of the IPS research. The monitoring system developed was based on using electric conductivity fundamentals and probes to detect the transport of chemical solution, calculate degree of saturation of sand, and determine the final zone of partial saturation created by IPS. To understand the fundamentals of electric conductivity, laboratory bench-top tests were conducted using electric conductivity probes and small specimens of Ottawa sand. Bench-top tests were used to study rate of generation of gas bubbles due to reaction of sodium percarbonate solution in sand, and to confirm a theory based on which degree of saturation were calculated. In addition to bench-top tests, electric conductivity probes were used in a relatively large sand specimen prepared in a specially manufactured glass tank. IPS was implemented in the prepared specimen to validate the numerical simulation model and explore the use of conductivity probes to detect the transport of chemical solution, estimate degree of saturation achieved due to injection of chemical solution, and evaluate final zone of partial saturation. The conductivity probe and the simulation results agreed well. To study the effect of IPS on liquefaction response of the sand specimen, IPS was implemented in a large (2-story high) sand specimen prepared in the laminar box of NEES Buffalo and then the specimen was subjected to harmonic shaking. Electric conductivity probes were used in the specimen treatment by controlling the duration and spacing of injection of the chemical solution, in monitoring the transport of chemical solution, in the estimation of zone of partial saturation achieved, and in the estimation of degree of saturation achieved due to implementation of IPS. The conductivity probes indicated partial saturation of the specimen. The shaking tests results confirmed the partial saturation state of the sand specimen. In addition, to the laboratory works, electric conductivity probes were used in field implementation of IPS in a pilot test at the Wildlife Liquefaction Array (WLA) of NEES UCSB site. The conductivity probes in the field test helped decide the optimum injection pressure, the injection tube spacing, and the degree of saturation that could be achieved in the field. The various laboratory and field tests confirmed that electric conductivity and the probes devised and used can be invaluable in the implementation of IPS, by providing information regarding transport of the chemical solution, the spacing of injection tubes, duration of injection, and the zone and degree of partial saturation caused by IPS.

  12. The dynamic properties behavior of high strength concrete under different strain rate

    NASA Astrophysics Data System (ADS)

    Abdullah, Hasballah; Husin, Saiful; Umar, Hamdani; Rizal, Samsul

    2005-04-01

    This paper present a number experimental data and numerical technique used in the dynamic behavior of high strength concrete. A testing device is presented for the experimental study of dynamic behavior material under high strain rates. The specimen is loaded by means of a high carbon steel Hopkinson pressure bar (40 mm diameter, 3000 mm long input bar and 1500 mm long out put bar) allowing for the testing of specimen diameter is large enough in relation to the size of aggregates. The other method also proposed for measuring tensile strength, the measurement method based on the superposition and concentration of tensile stress wave reflected both from the free-free ends of striking bar and the specimen bar. The compression Hopkinson bar test, the impact tensile test of high strength concrete bars are performed, together with compression static strength test. In addition, the relation between break position under finite element simulation and impact tensile strength are examined. The three-dimensional simulation of the specimen under transient loading are presented and comparisons between the experimental and numerical simulation on strain rate effects of constitutive law use in experimental are study.

  13. A novel method of testing the shear strength of thick honeycomb composites

    NASA Technical Reports Server (NTRS)

    Hodge, A. J.; Nettles, A. T.

    1991-01-01

    Sandwich composites of aluminum and glass/phenolic honeycomb core were tested for shear strength before and after impact damage. The assessment of shear strength was performed in two ways; by four point bend testing of sandwich beams and by a novel double lap shear (DLS) test. This testing technique was developed so smaller specimens could be used, thus making the use of common lab scale fabrication and testing possible. The two techniques yielded similar data. The DLS test gave slightly lower shear strength values of the two methods but were closer to the supplier's values for shear strength.

  14. Biomechanical Comparison of an Intramedullary and Extramedullary Free-Tissue Graft Reconstruction of the Acromioclavicular Joint Complex

    PubMed Central

    Garg, Rishi; Javidan, Pooya; Lee, Thay Q.

    2013-01-01

    Background Several different surgical techniques have been described to address the coracoclavicular (CC) ligaments in acromioclavicular (AC) joint injuries. However, very few techniques focus on reconstructing the AC ligaments, despite its importance in providing stability. The purpose of our study was to compare the biomechanical properties of two free-tissue graft techniques that reconstruct both the AC and CC ligaments in cadaveric shoulders, one with an extramedullary AC reconstruction and the other with an intramedullary AC reconstruction. We hypothesized intramedullary AC reconstruction will provide greater anteroposterior translational stability and improved load to failure characteristics than an extramedullary technique. Methods Six matched cadaveric shoulders underwent translational testing at 10 N and 15 N in the anteroposterior and superoinferior directions, under AC joint compression loads of 10 N, 20 N, and 30 N. After the AC and CC ligaments were transected, one of the specimens was randomly assigned the intramedullary free-tissue graft reconstruction while its matched pair received the extramedullary graft reconstruction. Both reconstructed specimens then underwent repeat translational testing, followed by load to failure testing, via superior clavicle distraction, at a rate of 50 mm/min. Results Intramedullary reconstruction provided significantly greater translational stability in the anteroposterior direction than the extramedullary technique for four of six loading conditions (p < 0.05). There were no significant differences in translational stability in the superoinferior direction for any loading condition. The intramedullary reconstructed specimens demonstrated improved load to failure characteristics with the intramedullary reconstruction having a lower deformation at yield and a higher ultimate load than the extramedullary reconstruction (p < 0.05). Conclusions Intramedullary reconstruction of the AC joint provides greater stability in the anteroposterior direction and improved load to failure characteristics than an extramedullary technique. Reconstruction of the injured AC joint with an intramedullary free tissue graft may provide greater strength and stability than other currently used techniques, allowing patients to have improved clinical outcomes. PMID:24340150

  15. Rapid viral diagnosis of acute respiratory infections: comparison of enzyme-linked immunosorbent assay and the immunofluorescence technique for detection of viral antigens in nasopharyngeal secretions.

    PubMed Central

    Grandien, M; Pettersson, C A; Gardner, P S; Linde, A; Stanton, A

    1985-01-01

    Nasopharyngeal secretions from adults and children were obtained in Stockholm, Sweden, for routine diagnosis of influenza A virus, influenza B virus, respiratory syncytial (RS) virus, parainfluenza type 3 virus, and adenovirus infections by demonstration of viral antigens directly in the specimens. The cells in nasopharyngeal secretions were pelleted by centrifugation for preparation of cell deposits for diagnosis by the immunofluorescence technique (IF) in London, England, and in Stockholm, whereas the supernatants were used to diagnose infection by the enzyme-linked immunosorbent assay (ELISA) in Stockholm. Titrations of the various purified viruses showed that ELISA could detect viral antigens in amounts corresponding to 1 to 10 ng of virus protein per test well. In a series of 73 specimens tested for influenza A, RS, and parainfluenza type 3 viruses by IF in London and by ELISA in Stockholm, 15 of 18 RS, 14 of 15 influenza A, and 2 of 2 parainfluenza type 3 viral infections were diagnosed by ELISA as compared with IF, giving sensitivities for RS and influenza A viral diagnosis of 83 and 93%, respectively, and a specificity of 100%. In another series of specimens from 35 patients tested for influenza B virus and adenovirus, five influenza B virus and four adenovirus infections were diagnosed by both methods; one additional influenza B infection was detected only by IF and another only by ELISA. Comparisons of diagnostic results between the two methods performed in Stockholm gave nonagreement of results for 37 of 1,593 tests (2.5%) for the five viruses. The conclusion reached was that the described ELISA, although a satisfactory test, had somewhat less sensitivity than did IF for the detection of respiratory viral infections. This could possibly be explained by unnecessary dilutions of specimens at the time of collection; transportation, processing, and storage of specimens were less complicated than for IF. PMID:2997270

  16. Recognizing defects in carbon-fiber reinforced plastics

    NASA Technical Reports Server (NTRS)

    Schuetze, R.; Hillger, W.

    1982-01-01

    The damage tolerance of structures made of carbon-fiber-reinforced plastic is tested under various loads. Test laminate (73/1/1, 24/9/1, 1465 A) specimens of thickness 1.5-3.2 mm with various defects were subjected to static and dynamic loads. Special attention was given to delamination, and ultrasonic C-scans were made on the specimens. It was shown that cracks from even small defects are detected with great accuracy. The same probes were also X rayed; defects that could not be detected under ordinary X rays were bored and studied under vacuum by a contrast technique. The nondestructive ultrasonic and X ray tests were controlled by partially destructive tests, and good agreement was observed.

  17. Analysis of Composite Skin-Stiffener Debond Specimens Using Volume Elements and a Shell/3D Modeling Technique

    NASA Technical Reports Server (NTRS)

    Krueger, Ronald; Minguet, Pierre J.; Bushnell, Dennis M. (Technical Monitor)

    2002-01-01

    The debonding of a skin/stringer specimen subjected to tension was studied using three-dimensional volume element modeling and computational fracture mechanics. Mixed mode strain energy release rates were calculated from finite element results using the virtual crack closure technique. The simulations revealed an increase in total energy release rate in the immediate vicinity of the free edges of the specimen. Correlation of the computed mixed-mode strain energy release rates along the delamination front contour with a two-dimensional mixed-mode interlaminar fracture criterion suggested that in spite of peak total energy release rates at the free edge the delamination would not advance at the edges first. The qualitative prediction of the shape of the delamination front was confirmed by X-ray photographs of a specimen taken during testing. The good correlation between prediction based on analysis and experiment demonstrated the efficiency of a mixed-mode failure analysis for the investigation of skin/stiffener separation due to delamination in the adherents. The application of a shell/3D modeling technique for the simulation of skin/stringer debond in a specimen subjected to three-point bending is also demonstrated. The global structure was modeled with shell elements. A local three-dimensional model, extending to about three specimen thicknesses on either side of the delamination front was used to capture the details of the damaged section. Computed total strain energy release rates and mixed-mode ratios obtained from shell/3D simulations were in good agreement with results obtained from full solid models. The good correlations of the results demonstrated the effectiveness of the shell/3D modeling technique for the investigation of skin/stiffener separation due to delamination in the adherents.

  18. 1000542

    NASA Image and Video Library

    2010-04-13

    HORACE STORNG (AEROSPACE ENGINEER, ER31 PROPULSION TURBOMACHINERY DESIGN & DEVELOPMENT BRANCH) ADJUSTS A UNIQUE MECHANICAL TEST SETUP THAT MEASURES STRAIN ON A SINGLE SAMPLE, USING TWO DIFFERENT TECHNIQUES AT THE SAME TIME. THE TEST FIXTURE HOLDS A SPECIMEN THAT REPRESENTS A LIQUID OXYGEN (LOX) BEARING FROM THE J2-X ENGINE

  19. Influence of gaseous hydrogen on the mechanical properties of high temperature alloys

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Tensile tests of six nickel-base and one cobalt-base alloy were conducted in 34.5 MN/sq m helium and hydrogen environments at temperatures from 297 K to 1,088 K. Mechanical properties tests of the nickel-base alloy MAR M-246 (Hf modified), in two cast conditions, were conducted in gaseous environments at temperatures from 297 K to 1,144 K and pressures from one atmosphere to 34.5 MN/sq m. The objective of this program was to obtain the mechanical properties of the various alloys proposed for use in space propulsion systems in a pure hydrogen environment at different temperatures and to compare with the mechanical properties in helium at the same conditions. All testing was conducted on solid specimens exposed to external gaseous pressure. Smooth and notched tensile properties were determined using ASTM tensile testing techniques, and creep-rupture life was determined using ASTM creep-rupture techniques. Low-cycle fatigue life was established by constant total strain and constant stress testing using smooth specimens and a closed-loop test machine.

  20. A mechanical system for tensile testing of supported films at the nanoscale.

    PubMed

    Pantano, Maria F; Speranza, G; Galiotis, Costas; Pugno, Nicola M

    2018-06-27

    Standard tensile tests of materials are usually performed on freestanding specimens. However, such requirement is difficult to implement when the materials of interest are of nanoscopic dimensions due to problems related to their handling and manipulation. In the present paper, a new device is presented for tensile testing of thin nanomaterials, which allows tests to be carried out on specimens initially deposited onto a macroscopic pre-notched substrate. On loading, however, no substrate effects are introduced, allowing the films to be freely stretched. The results obtained from a variety of thin metal or polymeric films are very promising for the further development of this technique as a standard method for nanomaterial mechanical testing. © 2018 IOP Publishing Ltd.

  1. A Specimen Size Effect on the Fatigue Crack Growth Rate Threshold of IN 718

    NASA Technical Reports Server (NTRS)

    Garr, K. R.; Hresko, G. C., III

    1998-01-01

    Fatigue crack growth rate (FCGR) tests were conducted on IN 718 in the solution annealed and aged condition at room temperature in accordance with E647-87. As part of each test, the FCGR threshold was measured using the decreasing Delta K method. A new heat of material was being tested and some of this material was sent to a different laboratory which wanted to use a specimen with a 127 mm width. Threshold data previously had been established on specimens with a width of 50.8 mm. As a check of the laboratory, tests were conducted at room temperature and R equal to 0.1 for comparison with the earlier data. The results were a threshold significantly higher than previously observed. Interchanging of specimen sizes and laboratories showed that the results were not due to a heat-to-heat or lab-to-lab variation. The results to be presented here are those obtained at the original laboratory. Growth rates were measured using the electric potential drop technique at R values of 0.1, 0.7, and 0.9. Compact tension specimen sizes with planer dimensions of 25.4 mm, 50.8 mm, and 127 mm were used. Crack growth rates at threshold were generally below 2.5 X 10(exp -8) mm / cycle. Closure measurements were made on some of the specimens by a manual procedure using a clip gage. When the crack growth rate data for the specimens tested at R equal to 0.1 were plotted as a function of applied Delta K, the thresholds varied with specimen width. The larger the width, the higher the threshold. The thresholds varied from 6.5 MPa-m(exp 1/2) for the 25.4 mm specimen to 15.4 MPa-m(exp 1/2) for the 127 mm specimen. At R equal to 0.7, the 25.4 mm and 50.8 mm specimens had essentially the same threshold, about 2.9 MPa-m(exp 1/2)while the 127 mm specimen had a threshold of 4.5 MPa-m(exp 1/2). When plotted as a function of effective Delta K, the R equal to 0.1 data are essentially normalized. Various aspects of the test procedure will be discussed as well as the results of analysis of the data using some different closure models.

  2. Thermomechanical testing techniques for high-temparature composites: TMF behavior of SiC(SCS-6)/Ti-15-3

    NASA Technical Reports Server (NTRS)

    Castelli, Michael G.; Ellis, J. Rodney; Bartolotta, Paul A.

    1990-01-01

    Thermomechanical testing techniques recently developed for monolithic structural alloys were successfully extended to continuous fiber reinforced composite materials in plate form. The success of this adaptation was verified on a model metal matrix composite (MMC) material, namely SiC(SCS-6)/Ti-15V-3Cr-3Al-3Sn. Effects of heating system type and specimen preparation are also addressed. Cyclic lives determined under full thermo-mechanical conditions were shown to be significantly reduced from those obtained under comparable isothermal and in-phase bi-thermal conditions. Fractography and metallography from specimens subjected to isothermal, out-of-phase and in-phase conditions reveal distinct differences in damage-failure modes. Isothermal metallography revealed extensive matrix cracking associated with fiber damage throughout the entire cross-section of the specimen. Out-of-phase metallography revealed extensive matrix damage associated with minimal (if any) fiber cracking. However, the damage was located exclusively at surface and near-surface locations. In-phase conditions produced extensive fiber cracking throughout the entire cross-section, associated with minimal (if any) matrix damage.

  3. Non-destructive examination of interfacial debonding using acoustic emission.

    PubMed

    Li, Haiyan; Li, Jianying; Yun, Xiaofei; Liu, Xiaozhou; Fok, Alex Siu-Lun

    2011-10-01

    This study aims to assess the viability of using the acoustic emission (AE) measurement technique to detect and monitor in situ the interfacial debonding in resin composite restorations due to build-up of shrinkage stresses during polymerization of the composite. The non-destructive testing technique that measures acoustic emission (AE) was used to detect and monitor the interfacial debonding in resin composite during curing of the composite. Four groups of specimens, n=4 each, were tested: (1) intact human molars with Class-I cavities restored with the composite Z100 (3M ESPE, USA); (2) intact human molars with Class-I cavities restored with the composite Filtek™ P90 (3M ESPE, USA); (3) ring samples prepared from the root of a single bovine tooth and 'restored' with Z100; (4) freestanding pea-size specimens of Z100 directly placed on the AE sensor. The restorations in Groups (1)-(3) were bonded to the tooth tissues with the adhesive Adper™ Scotchbond™ SE Self-Etch (3M ESPE, USA). The composites in all the specimens were cured with a blue light (3M ESPE, USA) for 40s. The AE signals were recorded continuously for 10 min from the start of curing. Non-destructive 3D imaging was performed using X-ray micro-computed tomography (micro-CT) to examine the bonding condition at the tooth-restoration interface. The development of AE events followed roughly that of the shrinkage stress, which was determined separately by the cantilever beam method. The number of AE events in the real human tooth samples was more than that in the ring samples, and no AE events were detected in the pea-size specimens placed directly on the AE sensor. The number of AE events recorded in the specimens restored using Z100 was more than that found in specimens restored with Filtek P90. The micro-CT imaging results showed clear interfacial debondings in the tooth specimens restored with Z100 after curing, but no clear debonding was found in the P90 specimens. The AE technique is an effective tool for detecting and monitoring in situ the interfacial debonding of composite restorations during curing. It can potentially be employed to evaluate the development of shrinkage stress and the quality of interfacial bonds in teeth restored with different composite materials, cavity geometries, and restorative techniques. Copyright © 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  4. 21 CFR 866.5180 - Fecal calprotectin immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... immunological test system is an in vitro diagnostic device that consists of reagents used to quantitatively measure, by immunochemical techniques, fecal calprotectin in human stool specimens. The device is intended forin vitro diagnostic use as an aid in the diagnosis of inflammatory bowel diseases (IBD), specifically...

  5. 1000538

    NASA Image and Video Library

    2010-04-13

    AYMAN GIRGIS (EM10 MATERIALS TEST ENGINEER, JACOBS ESTS GROUP/JTI) ADJUSTS DUAL LENSES FOR A UNIQUE MECHANICAL TST SETUP THAT MEASURES STRAIN ON A SINGLE SAMPLE, USING TWO DIFFERENT TECHNIQUES AT THE SAME TIME. THE TEST FIXTURE HOLDS A SPECIMEN THAT REPRESENTS A LIQUID OXYGEN (LOX) BEARING FROM THE J2-X ENGINE

  6. 1000540

    NASA Image and Video Library

    2010-04-13

    ERIC EARHART (AEROSPACE ENGINEER, ER41 PROPULSION STRUCTURAL & DYNAMICS ANALYSIS BRANCH) DISCUSSES DATA PRODUCED BY A UNIQUE MECHANICAL TEST SETUP THAT MEASURES STRAIN ON A SINGLE SAMPLE, USING TWO DIFFERENT TECHNIQUES AT THE SAME TIME. THE TEST FIXTURE HOLDS A SPECIMEN THAT REPRESENTS A LIQUID OXYGEN (LOX) BEARING FROM THE J2-X ENGINE

  7. Proposal of a punch biopsy protocol as a pre-requisite for the establishment of a tissue bank from resected esophageal tumors.

    PubMed

    Bonavina, Luigi; Laface, Letizia; Picozzi, Stefano; Nencioni, Marco; Siboni, Stefano; Bona, Davide; Sironi, Andrea; Sorba, Francesca; Clemente, Claudio

    2010-09-01

    With the development of tissue banking, a need for homogeneous methods of collection, processing, and storage of tissue has emerged. We describe the implementation of a biological bank in a high-volume, tertiary care University referral center for esophageal cancer surgery. We also propose an original punch biopsy technique of the surgical specimen. The method proved to be simple, reproducible, and not expensive. Unified standards for specimen collection are necessary to improve results of specimen-based diagnostic testing and research in surgical oncology.

  8. Examination of ceramic/enamel interfacial debonding using acoustic emission and optical coherence tomography.

    PubMed

    Lin, Chun-Li; Kuo, Wen-Chuan; Chang, Yen-Hsiang; Yu, Jin-Jie; Lin, Yun-Chu

    2014-08-01

    This study investigates monitored micro-crack growth and damage in the ceramic/enamel adhesive interface using the acoustic emission (AE) technique with optical coherence tomography (OCT) under fatigue shear testing. Shear bond strength (SBS) was measured first with eight prepared ceramic/enamel adhesive specimens under static loads. The fatigue shear testing was performed with three specimens at each cyclic load according to a modified ISO14801 method, applying at 80%, 75%, 70%, and 65% of the SBS to monitor interface debonding. The number of cycles at each load was recorded until ceramic/enamel adhesive interface debonding occurred. The AE technique was used to detect micro-crack signals in static and fatigue shear bond tests. The results showed that the average SBS value in the static tests was 18.07 ± 1.72 MPa (mean ± standard deviation), expressed in Newton's at 56.77 ± 5.40N. The average number of fatigue cycles in which ceramic/enamel interface damage was detected in 80%, 75%, 70% and 65% of the SBS were 41, 410, 8141 and 76,541, respectively. The acoustic behavior varied according to the applied load level. Events were emitted during 65% and 70% fatigue tests. A good correlation was observed between the crack location in OCT images and the number of AE signal hits. The AE technique combined with OCT images as a pre-clinical assessment tool to determine the integrity of cemented load bearing restored ceramic material. Sustainable cyclic load stresses in ceramic/enamel bonded specimens were substantially lower than the measured SBS. Predicted S-N curve showed that the maximum endured load was 10.98 MPa (about 34.48 N) passing 10(6) fatigue cyclic. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  9. Comparison of clinical results for the use of ethyl acetate and diethyl ether in the formalin-ether sedimentation technique performed on polyvinyl alcohol-preserved specimens.

    PubMed Central

    Garcia, L S; Shimizu, R

    1981-01-01

    One hundred fecal specimens preserved in polyvinyl alcohol fixative were examined by the Formalin-ether sedimentation technique with ethyl acetate substituted for diethyl ether. Technical performance of the procedures, appearance and amount of sediment obtained, and organism morphology were comparable. Also, ethyl acetate is less flammable and, therefore, less dangerous to use than diethyl ether. Results of parasite recovery when diethyl ether or ethyl acetate was used revealed few clinical relevant differences, most of which could also have been attributed to other variables inherent in this type of diagnostic testing. PMID:7229014

  10. Identification of Mycobacterium tuberculosis and rifampin resistance in clinical specimens using the Xpert MTB/RIF assay.

    PubMed

    Kim, Cheol-Hong; Hyun, In Gyu; Hwang, Yong Il; Kim, Dong-Gyu; Lee, Chang Youl; Lee, Myung Goo; Jung, Ki-Suck; Woo, Heungjeong; Hyun, Jeongwon; Kim, Hyun Soo; Park, Myung Jae

    2015-01-01

    The Xpert MTB/RIF assay is a novel real-time polymerase chain reaction technique for the detection of the Mycobacterium tuberculosis (MTB) complex and rifampin (RIF) resistance. We evaluated the performance of this assay in identifying MTB and resistance to RIF in clinical specimens. We analyzed clinical specimens from 383 patients with suspected TB who were hospitalized at a secondary hospital in Korea. Specimens were processed using the Xpert MTB/RIF assay, acid-fast bacilli smear and culture, and drug susceptibility test (DST). Among the 444 clinical samples analyzed, the Xpert MTB/RIF assay identified MTB in 56 (13.8%) of 405 respiratory specimens, but did not detect MTB in the remaining 39 non-respiratory specimens. Of the 65 pulmonary TB patients, 52 (80.0%) were confirmed by using mycobacterial culture as a reference standard. The sensitivity, specificity, PPV, and NPV of the Xpert MTB/RIF assay were 73.85%, 99.03%, 94.12%, and 94.72%, respectively. Among five patients with RIF resistance determined by the Xpert MTB/RIF assay, four (80%) were confirmed as suffering from multidrug-resistant (MDR) TB by DST. The Xpert MTB/RIF assay appears to be an accurate, simple, and useful technique for detecting MTB, especially in respiratory specimens. However, RIF resistance, if detected, should be verified with DST. © 2015 by the Association of Clinical Scientists, Inc.

  11. Characterization of cracking behavior using posttest fractographic analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kobayashi, T.; Shockey, D.A.

    A determination of time to initiation of stress corrosion cracking in structures and test specimens is important for performing structural failure analysis and for setting inspection intervals. Yet it is seldom possible to establish how much of a component's lifetime represents the time to initiation of fracture and how much represents postinitiation crack growth. This exploratory research project was undertaken to examine the feasibility of determining crack initiation times and crack growth rates from posttest examination of fracture surfaces of constant-extension-rate-test (CERT) specimens by using the fracture reconstruction applying surface topography analysis (FRASTA) technique. The specimens used in this studymore » were Type 304 stainless steel fractured in several boiling water reactor (BWR) aqueous environments. 2 refs., 25 figs., 2 tabs.« less

  12. Effect of bending on the room-temperature tensile strengths of structural ceramics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jenkins, M.G.

    1992-01-01

    Results for nearly fifty, room-temperature tensile tests conducted on two advanced, monolithic silicon nitride ceramics are evaluated for the effects of bending and application of various Weibull statistical analyses. Two specimen gripping systems (straight collet and tapered collet) were evaluated for both success in producing gage section failures and tendency to minimize bending at failure. Specimen fabrication and grinding technique consderations are briefly reviewed and related to their effects on successful tensile tests. Ultimate tensile strengths are related to the bending measured at specimen failure and the effects of the gripping system on bending are discussed. Finally, comparisons are mademore » between the use of censored and uncensored data sample sets for determining the maximum likelihood estimates of the Weibull parameters from the tensile strength distributions.« less

  13. Effect of bending on the room-temperature tensile strengths of structural ceramics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jenkins, M.G.

    1992-07-01

    Results for nearly fifty, room-temperature tensile tests conducted on two advanced, monolithic silicon nitride ceramics are evaluated for the effects of bending and application of various Weibull statistical analyses. Two specimen gripping systems (straight collet and tapered collet) were evaluated for both success in producing gage section failures and tendency to minimize bending at failure. Specimen fabrication and grinding technique consderations are briefly reviewed and related to their effects on successful tensile tests. Ultimate tensile strengths are related to the bending measured at specimen failure and the effects of the gripping system on bending are discussed. Finally, comparisons are mademore » between the use of censored and uncensored data sample sets for determining the maximum likelihood estimates of the Weibull parameters from the tensile strength distributions.« less

  14. Rapid, quantitative and sensitive immunochromatographic assay based on stripping voltammetric detection of a metal ion label

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, Fang; Wang, Kaihua; Lin, Yuehe

    2005-10-10

    A novel, sensitive immunochromatographic electrochemical biosensor (IEB) which combines an immunochromatographic strip technique with an electrochemical detection technique is demonstrated. The IEB takes advantages of the speed and low-cost of the conventional immunochromatographic test kits and high-sensitivity of stripping voltammetry. Bismuth ions (Bi3+) have been coupled with the antibody through the bifunctional chelating agent diethylenetriamine pentaacetic acid (DTPA). After immunoreactions, Bi3+ was released and quantified by anodic stripping voltammetry at a built-in single-use screen-printed electrode. As an example for the applications of such novel device, the detection of human chorionic gonadotronphin (HCG) in a specimen was performed. This biosensor providesmore » a more user-friendly, rapid, clinically accurate, and less expensive immunoassay for such analysis in specimens than currently available test kits.« less

  15. A study of the stress wave factor technique for the characterization of composite materials

    NASA Technical Reports Server (NTRS)

    Henneke, E. G., II; Duke, J. C., Jr.; Stinchcomb, W. W.; Govada, A.; Lemascon, A.

    1983-01-01

    A testing program was undertaken to provide an independent investigation and evaluation of the stress wave factor for characterizing the mechanical behavior of composite laminates. Some of the data which was obtained after performing a very large number of tests to determine the reproducibility of the SWF measurement is presented. It was determined that, with some optimizing of experimental parameters, the SWF value can be reproduced to within + or - 10%. Results are also given which show that, after careful calibration procedures, the lowest SWF value along the length of a specimen will correlate very closely to the site of final failure when the specimen is loaded in tension. Finally, using a moire interferometry technique, it was found that local regions having the highest in plane strains under tensile loading also had the lowest SWF values.

  16. Nuclear Technology. Course 32: Nondestructive Examination (NDE) II. Module 32-3, Fundamentals of Magnetic Particle Testing.

    ERIC Educational Resources Information Center

    Groseclose, Richard

    This third in a series of six modules for a course titled Nondestructive Examination (NDE) Techniques II explains the principles of magnets and magnetic fields and how they are applied in magnetic particle testing, describes the theory and methods of magnetizing test specimens, describes the test equipment used, discusses the principles and…

  17. Refining the 'cucumber' technique for laryngeal biopsy.

    PubMed

    Robertson, S; Cooper, L; McPhaden, A; MacKenzie, K

    2011-06-01

    To refine the case selection process for the 'cucumber' mounting system for laryngeal biopsies. We conducted a retrospective audit of cucumber technique specimens taken between January 2002 and December 2008. We analysed the clinical indications for biopsy and the pathological diagnosis, for each specimen, in order to inform our case selection process. The cucumber technique was used for 125 laryngeal specimens. 60 specimens were taken for diagnostic sampling, 46 were taken during endoscopic laser resection, and 19 for overtly benign pathology. The cucumber technique was most useful for the interpretation of margins in endoscopic laser resection specimens. The cucumber technique is most useful for endoscopic resection cases in which tumour, dysplasia or suspicious lesions have been excised. Detailed information on resection margins is invaluable during multidisciplinary team discussions on patient management. Detailed photography of mounted specimens enables both laryngologist and pathologist to orientate and interpret specimens accurately.

  18. Characterization of Fatigue Damage for Bonded Composite Skin/Stringer Configurations

    NASA Technical Reports Server (NTRS)

    Paris, Isabelle; Cvitkovich, Michael; Krueger, Ronald

    2008-01-01

    The fatigue damage was characterized in specimens which consisted of a tapered composite flange bonded onto a composite skin. Quasi-static tension tests were performed first to determine the failure load. Subsequently, tension fatigue tests were performed at 40%, 50%, 60% and 70% of the failure load to evaluate the debonding mechanisms. For four specimens, the cycling loading was stopped at intervals. Photographs of the polished specimen edges were taken under a light microscope to document the damage. At two diagonally opposite corners of the flange, a delamination appeared to initiate at the flange tip from a matrix crack in the top 45deg skin ply and propagated at the top 45deg/-45deg skin ply interface. At the other two diagonally opposite corners, a delamination running in the bondline initiated from a matrix crack in the adhesive pocket. In addition, two specimens were cut longitudinally into several sections. Micrographs revealed a more complex pattern inside the specimen where the two delamination patterns observed at the edges are present simultaneously across most of the width of the specimen. The observations suggest that a more sophisticated nondestructive evaluation technique is required to capture the complex damage pattern of matrix cracking and multi-level delaminations.

  19. Use of real-time PCR to detect canine parvovirus in feces of free-ranging wolves.

    PubMed

    Mech, L David; Almberg, Emily S; Smith, Douglas; Goyal, Sagar; Singer, Randall S

    2012-04-01

    Using real-time PCR, we tested 15 wolf (Canis lupus) feces from the Superior National Forest (SNF), Minnesota, USA, and 191 from Yellowstone National Park (YNP), USA, collected during summer and 13 during winter for canine parvovirus (CPV)-2 DNA. We also tested 20 dog feces for CPV-2 DNA. The PCR assay was 100% sensitive and specific with a minimum detection threshold of 10(4) 50% tissue culture infective dose. Virus was detected in two winter specimens but none of the summer specimens. We suggest applying the technique more broadly especially with winter feces.

  20. Use of real-time PCR to detect canine parvovirus in feces of free-ranging wolves

    USGS Publications Warehouse

    Mech, L. David; Almberg, Emily S.; Smith, Douglas; Goyal, Sagar; Singer, Randall S.

    2012-01-01

    Using real-time PCR, we tested 15 wolf (Canis lupus) feces from the Superior National Forest (SNF), Minnesota, USA, and 191 from Yellowstone National Park (YNP), USA, collected during summer and 13 during winter for canine parvovirus (CPV)-2 DNA. We also tested 20 dog feces for CPV-2 DNA. The PCR assay was 100% sensitive and specific with a minimum detection threshold of 104 50% tissue culture infective dose. Virus was detected in two winter specimens but none of the summer specimens. We suggest applying the technique more broadly especially with winter feces.

  1. Non-destructive testing techniques for the forensic engineering investigation of reinforced concrete buildings.

    PubMed

    Hobbs, Brian; Tchoketch Kebir, Mohamed

    2007-04-11

    This study describes in detail the results of a laboratory investigation where the compressive strength of 150mm side-length cubes was evaluated. Non-destructive testing (NDT) was carried out using ultrasonic pulse velocity (UPV) and impact rebound hammer (IRH) techniques to establish a correlation with the compressive strengths of compression tests. To adapt the Schmidt hammer apparatus and the ultrasonic pulse velocity tester to the type of concrete used in Algeria, concrete mix proportions that are recommended by the Algerian code were chosen. The resulting correlation curve for each test is obtained by changing the level of compaction, water/cement ratio and concrete age of specimens. Unlike other works, the research highlights the significant effect of formwork material on surface hardness of concrete where two different mould materials for specimens were used (plastic and wood). A combined method for the above two tests, reveals an improvement in the strength estimation of concrete. The latter shows more improvement by including the concrete density. The resulting calibration curves for strength estimation were compared with others from previous published literature.

  2. Shear compression testing of glass-fibre steel specimens after 4K reactor irradiation: Present status and facility upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gerstenberg, H.; Kraehling, E.; Katheder, H.

    1997-06-01

    The shear strengths of various fibre reinforced resins being promising candidate insulators for superconducting coils to be used tinder a strong radiation load, e.g. in future fusion reactors were investigated prior and subsequent to reactor in-core irradiation at liquid helium temperature. A large number of sandwich-like (steel-bonded insulation-steel) specimens representing a widespread variety of materials and preparation techniques was exposed to irradiation doses of up to 5 x 10{sup 7} Gy in form of fast neutrons and {gamma}-radiation. In a systematic study several experimental parameters including irradiation dose, postirradiation storage temperature and measuring temperature were varied before the determination ofmore » the ultimate shear strength. The results obtained from the different tested materials are compared. In addition an upgrade of the in-situ test rig installed at the Munich research reactor is presented, which allows combined shear/compression loading of low temperature irradiated specimens and provides a doubling of the testing rate.« less

  3. 1000539

    NASA Image and Video Library

    2010-04-13

    AYMAN GIRGIS (EM10 MATERIALS TEST ENGINEER, JACOBS ESTS GROUP/JTI) AND ERIC EARHART (AEROSPACE ENGINEER, ER41 PROPULSION STRUCTURAL & DYNAMICS ANALYSIS BRANCH) DISCUSS DATA PRODUCED BY A UNIQUE MECHANICAL TEST SETUP THAT MEASURES STRAIN ON A SINGLE SAMPLE, USING TWO DIFFERENT TECHNIQUES AT THE SAME TIME. THE TEST FIXTURE HOLDS A SPECIMEN THAT REPRESENTS A LIQUID OXYGEN (LOX) BEARING FROM THE J2-X ENGINE.

  4. Serological diagnosis of pneumocystosis: production of a synthetic recombinant antigen for immunodetection of Pneumocystis jirovecii.

    PubMed

    Tomás, A L; Cardoso, F; Esteves, F; Matos, O

    2016-11-08

    Diagnosis of Pneumocystis pneumonia (PcP) relies on the detection of P. jirovecii in respiratory specimens obtained by invasive techniques. Thus, the development of a serological test is urgently needed as it will allow the diagnosis of PcP using blood, an inexpensive and non-invasive specimen. This study aims to combine the production of a multi-epitope synthetic recombinant antigen (RSA) and an ELISA test for detection of anti-P. jirovecii antibodies, in order to develop a new approach for PcP diagnosis. The RSA was selected and designed based on the study of the immunogenicity of the carboxyl-terminal domain of the major surface glycoprotein. This antigen was purified and used as an antigenic tool in an ELISA technique for detection of Ig, IgG and IgM antibodies anti-P. jirovecii (patent-pending no. PT109078). Serum specimens from 88 patients previously categorized in distinct clinical subgroups and 17 blood donors, were analysed. The IgM anti-P. jirovecii levels were statistically increased in patients with PcP (p = 0.001) and the ELISA IgM anti-P. jirovecii test presented a sensitivity of 100% and a specificity of 80.8%, when associated with the clinical diagnosis criteria. This innovative approach, provides good insights about what can be done in the future serum testing for PcP diagnosis.

  5. Serological diagnosis of pneumocystosis: production of a synthetic recombinant antigen for immunodetection of Pneumocystis jirovecii

    PubMed Central

    Tomás, A. L.; Cardoso, F.; Esteves, F.; Matos, O.

    2016-01-01

    Diagnosis of Pneumocystis pneumonia (PcP) relies on the detection of P. jirovecii in respiratory specimens obtained by invasive techniques. Thus, the development of a serological test is urgently needed as it will allow the diagnosis of PcP using blood, an inexpensive and non-invasive specimen. This study aims to combine the production of a multi-epitope synthetic recombinant antigen (RSA) and an ELISA test for detection of anti-P. jirovecii antibodies, in order to develop a new approach for PcP diagnosis. The RSA was selected and designed based on the study of the immunogenicity of the carboxyl-terminal domain of the major surface glycoprotein. This antigen was purified and used as an antigenic tool in an ELISA technique for detection of Ig, IgG and IgM antibodies anti-P. jirovecii (patent-pending no. PT109078). Serum specimens from 88 patients previously categorized in distinct clinical subgroups and 17 blood donors, were analysed. The IgM anti-P. jirovecii levels were statistically increased in patients with PcP (p = 0.001) and the ELISA IgM anti-P. jirovecii test presented a sensitivity of 100% and a specificity of 80.8%, when associated with the clinical diagnosis criteria. This innovative approach, provides good insights about what can be done in the future serum testing for PcP diagnosis. PMID:27824115

  6. A systematic methodology for creep master curve construction using the stepped isostress method (SSM): a numerical assessment

    NASA Astrophysics Data System (ADS)

    Miranda Guedes, Rui

    2018-02-01

    Long-term creep of viscoelastic materials is experimentally inferred through accelerating techniques based on the time-temperature superposition principle (TTSP) or on the time-stress superposition principle (TSSP). According to these principles, a given property measured for short times at a higher temperature or higher stress level remains the same as that obtained for longer times at a lower temperature or lower stress level, except that the curves are shifted parallel to the horizontal axis, matching a master curve. These procedures enable the construction of creep master curves with short-term experimental tests. The Stepped Isostress Method (SSM) is an evolution of the classical TSSP method. Higher reduction of the required number of test specimens to obtain the master curve is achieved by the SSM technique, since only one specimen is necessary. The classical approach, using creep tests, demands at least one specimen per each stress level to produce a set of creep curves upon which TSSP is applied to obtain the master curve. This work proposes an analytical method to process the SSM raw data. The method is validated using numerical simulations to reproduce the SSM tests based on two different viscoelastic models. One model represents the viscoelastic behavior of a graphite/epoxy laminate and the other represents an adhesive based on epoxy resin.

  7. Development of a thermally-assisted piercing (TAP) process for introducing holes into thermoplastic composites

    NASA Astrophysics Data System (ADS)

    Brown, Nicholas W. A.

    Composite parts can be manufactured to near-net shape with minimum wastage of material; however, there is almost always a need for further machining. The most common post-manufacture machining operations for composite materials are to create holes for assembly. This thesis presents and discusses a thermally-assisted piercing process that can be used as a technique for introducing holes into thermoplastic composites. The thermally-assisted piercing process heats up, and locally melts, thermoplastic composites to allow material to be displaced around a hole, rather than cutting them out from the structure. This investigation was concerned with how the variation of piercing process parameters (such as the size of the heated area, the temperature of the laminate prior to piercing and the geometry of the piercing spike) changed the material microstructure within carbon fibre/Polyetheretherketone (PEEK) laminates. The variation of process parameters was found to significantly affect the formation of resin rich regions, voids and the fibre volume fraction in the material surrounding the hole. Mechanical testing (using open-hole tension, open-hole compression, plain-pin bearing and bolted bearing tests) showed that the microstructural features created during piercing were having significant influence over the resulting mechanical performance of specimens. By optimising the process parameters strength improvements of up to 11% and 21% were found for pierced specimens when compared with drilled specimens for open-hole tension and compression loading, respectively. For plain-pin and bolted bearing tests, maximum strengths of 77% and 85%, respectively, were achieved when compared with drilled holes. Improvements in first failure force (by 10%) and the stress at 4% hole elongation (by 18%), however, were measured for the bolted bearing tests when compared to drilled specimens. The overall performance of pierced specimens in an industrially relevant application ultimately depends on the properties required for that specific scenario. The results within this thesis show that the piercing technique could be used as a direct replacement to drilling depending on this application.

  8. The vector homology problem in diagnostic nucleic acid hybridization of clinical specimens.

    PubMed Central

    Ambinder, R F; Charache, P; Staal, S; Wright, P; Forman, M; Hayward, S D; Hayward, G S

    1986-01-01

    Nucleic acid hybridization techniques using cloned probes are finding application in assays of clinical specimens in research and diagnostic laboratories. The probes that we and others have used are recombinant plasmids composed of viral inserts and bacterial plasmid vectors such as pBR322. We suspected that there was material homologous to pBR322 present in many clinical samples. because hybridization occurred in samples which lacked evidence of virus by other techniques. If the presence of this vector-homologous material was unrecognized, hybridization in the test sample might erroneously be interpreted as indicating the presence of viral sequences. In this paper we demonstrate specific hybridization of labeled pBR322 DNA with DNA from various clinical samples. Evidence is presented that nonspecific probe trapping could not account for this phenomenon. In mixing experiments, it is shown that contamination of clinical samples with bacteria would explain such a result. Approaches tested to circumvent this problem included the use of isolated insert probes, alternate cloning vectors, and cold competitor pBR322 DNA in prehybridization and hybridization mixes. None proved entirely satisfactory. We therefore emphasize that it is essential that all hybridization detection systems use a control probe of the vector alone in order to demonstrate the absence of material with vector homology in the specimen tested. Images PMID:3013928

  9. Patterns of detection of Strongyloides stercoralis in stool specimens: implications for diagnosis and clinical trials.

    PubMed Central

    Dreyer, G; Fernandes-Silva, E; Alves, S; Rocha, A; Albuquerque, R; Addiss, D

    1996-01-01

    Reported efficacies of drugs used to treat Strongyloides stercoralis infection vary widely. Because diagnostic methods are insensitive, therapeutic trials generally require multiple negative posttreatment stool specimens as evidence of drug efficacy. However, only a single positive stool specimen is usually required for study enrollment. To determine the reproducibility of detection of S. stercoralis larvae in the stool, 108 asymptomatic infected men submitted 25 g of fresh stool once a week for eight consecutive weeks for examination by the Baermann technique. During the 8-week study, 239 (27.7%) of 864 stool specimens were positive for S. stercoralis. Rates of detection of larvae in the stool specimens ranged from eight of eight specimens in 3 (2.8%) men to none of eight specimens in 36 (33.3%) men. Of 43 men for whom S. stercoralis was detected in at least two of the first four stool specimens, only 1 (2.3%) man tested negative on all of the next four specimens. In comparison, of 29 men who had detectable larvae in only one of the first four specimens, 22 (75.9%) tested negative on all of the next four samples. Thus, if these 29 men had been enrolled in a therapeutic trial between the first and second sets of four specimens, the efficacy of a drug with no activity against this parasite would have been estimated to be 76%. These data suggest that patterns of S. stercoralis detection vary widely among infected persons and that intermittent larval shedding can lead to inflated estimates of drug efficacy. Before a patient is entered in a clinical trial of drug efficacy, four consecutive stool specimens should be examined for S. stercoralis; only persons with two or more positive specimens should be enrolled. PMID:8880521

  10. Application of Desalination with CFRP Composite Electrode to Concrete Deteriorated by Chloride Attack

    NASA Astrophysics Data System (ADS)

    Yamaguchi, Keisuke; Ueda, Takao; Nanasawa, Akira

    As a new rehabilitation technique for recovery both of loading ability and durability of concrete structures deteriorated by chloride attack, desalination (electrochemical chloride removal technique from concrete) using CFRP composite electrode bonding to concrete has been developed. In this study, basic application was tried using small RC specimens, and also application to the large-scale RC beams deteriorated by the chloride attack through the long-term exposure in the outdoors was investigated. As the result of bending test of treated specimens, the decrease of strengthening effect with the electrochemical treatment was observed in the case of small specimens using low absorption rate resin for bonding, on the other hand, in the case of large-scale RC beam using 20% absorption rate resin for bonding CFRP composite electrode, enough strengthening effect was obtained by the bending failure of RC beam with the fracture of CFRP board.

  11. The fatigue life of a cobalt-chromium alloy after laser welding.

    PubMed

    Al-Bayaa, Nabil Jalal Ahmad; Clark, Robert K F; Juszczyk, Andrzej S; Radford, David R

    2011-03-01

    The aim of this study was to investigate the fatigue life of laser welded joints in a commercially available cast cobalt-chromium alloy. Twenty rod shaped specimens (40 mm x 1.5 mm) were cast and sand blasted. Ten specimens were used as controls and the remaining ten were sectioned and repaired using a pulsed Nd: YAG laser welder. All specimens were subjected to fatigue testing (30N - 2Hz) in a controlled environment. A statistically significant difference in median fatigue life was found between as-cast and laser welded specimens (p < 0.001). Consequently, the technique may not be appropriate for repairing cobalt chromium clasps on removable partial dentures. Scanning electron microscopy indicated the presence of cracks, pores and constriction of the outer surface in the welded specimens despite 70% penetration of the weld.

  12. Detecting barely visible impact damages of honeycomb and laminate CFRP using digital shearography

    NASA Astrophysics Data System (ADS)

    Burkov, Mikhail; Lyubutin, Pavel; Byakov, Anton; Panin, Sergey

    2017-12-01

    The paper deals with testing of the developed shearographic device and signal processing software applied for nondestructive testing/evaluation (NDT/E) of carbon fiber reinforced polymers (CFRP). There were 4 types of test specimens: laminate CFRP, honeycomb CFRP, laminate CFRP with the channel stiffener, and laminate CFRP bolted with the aluminum plate. All the specimens were subjected to impact loading using the drop weight technique according to the ASTM D7136 standard in order to produce barely visible impact damages (BVID). The obtained shearograms easily reveal BVIDs as nonuniformities in strain fields. The results are analyzed and discussed in view of the sensitivity of shearography to delamination and debonding.

  13. Fracture Behavior of Ceramics Under Displacement Controlled Loading

    NASA Technical Reports Server (NTRS)

    Calomino, Anthony; Brewer, David; Ghosn, Louis

    1994-01-01

    A Mode I fracture specimen and loading method has been developed which permits the observation of stable crack extension in monolithic and in situ toughened ceramics. The developed technique was used to conduct room temperature tests on commercial grade alumina (Coors' AD-995) and silicon nitride (Norton NC-132). The results of these tests are reported. Crack growth for the alumina remained subcritical throughout testing revealing possible effects of environmental stress corrosion. The crack growth resistance curve for the alumina is presented. The silicon nitride tests displayed a series of stable (slow) crack growth segments interrupted by dynamic (rapid) crack extension. Crack initiation and arrest stress intensity factors, K(sub Ic) and K(sub Ia), for silicon nitride are reported. The evolution of the specimen design through testing is briefly discussed.

  14. Overview on Techniques to Construct Tissue Arrays with Special Emphasis on Tissue Microarrays

    PubMed Central

    Vogel, Ulrich

    2014-01-01

    With the advent of new histopathological staining techniques (histochemistry, immunohistochemistry, in situ hybridization) and the discovery of thousands of new genes, mRNA, and proteins by molecular biology, the need grew for a technique to compare many different cells or tissues on one slide in a cost effective manner and with the possibility to easily track the identity of each specimen: the tissue array (TA). Basically, a TA consists of at least two different specimens per slide. TAs differ in the kind of specimens, the number of specimens installed, the dimension of the specimens, the arrangement of the specimens, the embedding medium, the technique to prepare the specimens to be installed, and the technique to construct the TA itself. A TA can be constructed by arranging the tissue specimens in a mold and subsequently pouring the mold with the embedding medium of choice. In contrast, preformed so-called recipient blocks consisting of the embedding medium of choice have punched, drilled, or poured holes of different diameters and distances in which the cells or tissue biopsies will be deployed manually, semi-automatically, or automatically. The costs of constructing a TA differ from a few to thousands of Euros depending on the technique/equipment used. Remarkably high quality TAs can be also achieved by low cost techniques. PMID:27600339

  15. Linear Array Ultrasonic Test Results from Alkali-Silica Reaction (ASR) Specimens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clayton, Dwight A; Khazanovich, Dr. Lev; Salles, Lucio

    2016-04-01

    The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years. Since many important safety structures in an NPP are constructed of concrete, inspection techniques must be developed and tested to evaluate the internal condition. In-service containment structures generally do not allow for the destructive measures necessary to validate the accuracy of these inspection techniques. This creates a need for comparative testing of the variousmore » nondestructive evaluation (NDE) measurement techniques on concrete specimens with known material properties, voids, internal microstructure flaws, and reinforcement locations.This report presents results of the ultrasound evaluation of four concrete slabs with varying levels of ASR damage present. This included an investigation of the experimental results, as well as a supplemental simulation considering the effect of ASR damage by elasto-dynamic wave propagation using a finite integration technique method. It was found that the Hilbert Transform Indicator (HTI), developed for quantification of freeze/thaw damage in concrete structures, could also be successfully utilized for quantification of ASR damage. internal microstructure flaws, and reinforcement locations.« less

  16. Designing a Uniaxial Tension/Compression Test for Springback Analysis in High-Strength Steel Sheets

    PubMed Central

    Stoudt, M. R.; Levine, L. E.; Ma, L.

    2016-01-01

    We describe an innovative design for an in-plane measurement technique that subjects thin sheet metal specimens to bidirectional loading. The goal of this measurement is to provide the critical performance data necessary to validate complex predictions of the work hardening behavior during reversed uniaxial deformation. In this approach, all of the principal forces applied to the specimen are continually measured in real-time throughout the test. This includes the lateral forces that are required to prevent out of plane displacements in the specimen that promote buckling. This additional information will, in turn, improve the accuracy of the compensation for the friction generated between the anti-bucking guides and the specimen during compression. The results from an initial series of experiments not only demonstrate that our approach is feasible, but that it generates data with the accuracy necessary to quantify the directionally-dependent changes in the yield behavior that occur when the strain path is reversed (i.e., the Bauschinger Effect). PMID:28133391

  17. Speckle-interferometric measurement system of 3D deformation to obtain thickness changes of thin specimen under tensile loads

    NASA Astrophysics Data System (ADS)

    Kowarsch, Robert; Zhang, Jiajun; Sguazzo, Carmen; Hartmann, Stefan; Rembe, Christian

    2017-06-01

    The analysis of materials and geometries in tensile tests and the extraction of mechanic parameters is an important field in solid mechanics. Especially the measurement of thickness changes is important to obtain accurate strain information of specimens under tensile loads. Current optical measurement methods comprising 3D digital image correlation enable thickness-change measurement only with nm-resolution. We present a phase-shifting electronic speckle-pattern interferometer in combination with speckle-correlation technique to measure the 3D deformation. The phase-shift for the interferometer is introduced by fast wavelength tuning of a visible diode laser by injection current. In a post-processing step, both measurements can be combined to reconstruct the 3D deformation. In this contribution, results of a 3Ddeformation measurement for a polymer membrane are presented. These measurements show sufficient resolution for the detection of 3D deformations of thin specimen in tensile test. In future work we address the thickness changes of thin specimen under tensile loads.

  18. Preliminary studies of primary ostrich fibroblasts for the isolation of ratite viruses.

    PubMed

    Rodgers, S J; Vanhooser, S L; Welsh, R D; Silkwood, T G

    1994-01-01

    An ostrich egg at 21 days of development was used to propagate primary embryo cell cultures. Primary cultures of skeletal muscle cells (for fibroblasts) were prepared by routine typsinization techniques. The ostrich embryo fibroblasts were tested for their ability to propagate stock avian viruses of infectious bronchitis virus, paramyxiovirus-1 (PMV-1), PMV-2, PMV-3, infectious bursal disease virus, quail bronchitis virus, avian reovirus, turkey coronavirus, and two ostrich-originating specimens (one of which was a possible coronavirus identified by electron microscopy). Cytopathic effects were seen by light microscopy in cell cultures inoculated with PMV-1, turkey coronavirus, and the two ostrich specimens. Hemaglutinating titers of 4 or more were determined for PMV-1, turkey coronavrius, and the two ostrich specimens after inoculation onto monolayers of ostrich embryo fibroblasts. Hemagglutination-inhibition tests confirmed the identification of PMV-1 when homologous antisera were used as the specific inhibitor. Bovine coronavirus antisera inhibited the hemagglutination of one of the cultured ostrich specimens.

  19. Rapid diagnostic methods for influenza virus in clinical specimens - A comparative study

    NASA Technical Reports Server (NTRS)

    Evans, A. S.; Olson, B.

    1982-01-01

    A comparison of five rapid viral diagnostic techniques for identifying influenza virus in nasopharyngeal aspirates has been made on patients with influenza-like illnesses. Initial results with immune electron microscopy were positive in only one of 11 specimens from which virus was isolated and further work abandoned. Four other rapid tests were carried out on 39 specimens from which influenza virus had been isolated in tissue culture in 28. Of these 28 specimens yielding virus, 24 (85.7 percent) were positive by an indirect fluorescent antibody test (IFAT) on nasopharyngeal cells, 18 (64.3 percent) by enzyme-linked immunosorbent assay (ELISA), 19 (67.8 percent) by enzyme-linked fluorescent assay (ELFA), and 26 (92.8 percent) by a rapid tissue culture amplification method (TCA) in a continuous Rhesus monkey kidney line (LLC-MK2) with identification of virus by fluorescent antibody. In terms of sensitivity, simplicity, and rapidity, a combination of the IFAT and TCA methods seems to be very useful.

  20. Vibration damping characteristics of graphite/epoxy composites for large space structures

    NASA Technical Reports Server (NTRS)

    Gibson, R. F.

    1982-01-01

    Limited data on extensional and flexural damping of small specimens of graphite/epoxy and unreinforced epoxy resin were obtained. Flexural damping was measured using a forced vibration technique based on resonant flexural vibration of shaker excited double cantilever specimens. Extensional damping was measured by subjecting similar specimens to low frequency sinusoidal oscillation in a servohydraulic tensile testing machine while plotting load versus extensional strain. Damping was found to vary slowly and continuously over the frequency range 0.01 - 1000 Hz, and no drastic transitions were observed. Composite damping was found to be less than neat resin damping. Comparison of small specimen damping values with assembled column damping values seems to indicate that, for those materials, material damping is more important than joint damping. The data reported was limited not by the test apparatus, but by signal conditioning and data acquisition. It is believed that filtering of the strain gage signals and the use of digital storage with slow playback will make it possible to extend the frequency and amplitude ranges significantly.

  1. Evaluation of lateral flow devices for identification of infected poultry by testing swab and feather specimens during H5N1 highly pathogenic avian influenza outbreaks in Vietnam.

    PubMed

    Slomka, Marek J; To, Thanh L; Tong, Hien H; Coward, Vivien J; Mawhinney, Ian C; Banks, Jill; Brown, Ian H

    2012-09-01

    Evaluation of two commercial lateral flow devices (LFDs) for avian influenza (AI) detection in H5N1 highly pathogenic AI infected poultry in Vietnam. Determine sensitivity and specificity of the LFDs relative to a validated highly sensitive H5 RRT PCR. Swabs (cloacal and tracheal) and feathers were collected from 46 chickens and 48 ducks (282 clinical specimens) and tested by both LFDs and H5 RRT PCR. A subset of 59 chicken and 34 duck specimens was also tested by virus isolation (VI), the 'gold standard'. Twenty-six chickens and 15 ducks were shown to be infected by at least one RRT PCR positive clinical specimen per bird. Bird-level sensitivity for the Anigen LFD was 84·6% for chickens and 53·3% for ducks, and for the Quickvue LFD 65·4% for chickens and 33·3% for ducks. Comparison of the three clinical specimens revealed that chicken feathers were the most sensitive with 84% and 56% sensitivities for Anigen and Quickvue respectively. All 21 RRT PCR positive swabs from ducks were negative by both LFDs. However, duck feather testing gave sensitivities of 53·3% and 33·3% for Anigen and Quickvue respectively. Specificity was 100% for both LFDs in all investigations. Although LFDs were less sensitive than AI RRT PCR and VI, high titre viral shedding in H5N1 highly pathogenic avian influenza (HPAI) infected and diseased chickens is sufficient for a proportion of birds to be identified as AI infected by LFDs. Feathers were the optimal specimen for LFD testing in such diseased HPAI scenarios, particularly for ducks where swab testing by LFDs failed to identify any infected birds. However, specimens should be forwarded to the laboratory for confirmation by more sensitive diagnostic techniques. © 2011 Blackwell Publishing Ltd.

  2. A technique for measurement of material damping in metals. [absorption of structural vibration

    NASA Technical Reports Server (NTRS)

    Heine, J. C.

    1976-01-01

    The paper outlines the theory, design, and application of an apparatus based on the single beam resonant dwell technique to determine the damping capacity of metallic materials by measuring the response of a structural element to excitation at a modal frequency. In this apparatus, a cantilever beam specimen of a test material is clamped to a bar which is connected at one end to an electromagnetic shaker and at the other to a heavy base. The thickness of the bar at the base end is reduced by two saw cuts to provide a pivot around which the remainder of the bar can rotate when excited by the shaker which is connected to the bar by a rod passing through a hole in the base. The response of the supporting system to shaker excitation is measured with an accelerometer mounted on the bar at the root of the specimen. Specimen response is measured optically with a low-power microscope with a reticle. Specimen loss factor is determined in terms of acceleration at the beam root, beam tip displacement, and the beam natural frequency.

  3. Roughness and compressive strength of FDM 3D printed specimens affected by acetone vapour treatment

    NASA Astrophysics Data System (ADS)

    Beniak, Juraj; Križan, Peter; Šooš, Ľubomír; Matúš, Miloš

    2018-01-01

    Rapid Prototyping technologies are the fastest growing technologies in the manufacturing of components and parts. There are many techniques which can be used with different materials and different purposes of produced part. Gradually, Rapid Prototyping systems have grown into Additive Manufacturing, because technology expansion brings faster production, improved manufactured components, and expanded palette of used materials. So now this techniques are also used for regular production of special parts, where is usual change of part design, where is necessary to produce variety of different designs and shapes. The following article deals with Fused Deposition Modelling (FDM) technology, the core of which is the manufacture models and components from thermoplastic polymers by deposition single fibres of semi-molten plastic material layer by layer. The article focuses on the results of research for testing of manufactured specimens by FDM technology. Components are modified by acetone vapour for surface smoothing. The purpose is to point out how the additional specimen treatment influence the strength properties. Presented paper shows realized experiments and measurements of compressive force on specimens and surface roughness which are influenced by acetone vapour treatment.

  4. Tensile and fatigue behavior of polymer composites reinforced with superelastic SMA strands

    NASA Astrophysics Data System (ADS)

    Daghash, Sherif M.; Ozbulut, Osman E.

    2018-06-01

    This study explores the use of superelastic shape memory alloy (SMA) strands, which consist of seven individual small-diameter wires, in an epoxy matrix and characterizes the tensile and fatigue responses of the developed SMA/epoxy composites. Using a vacuum assisted hand lay-up technique, twelve SMA fiber reinforced polymer (FRP) specimens were fabricated. The developed SMA-FRP composites had a fiber volume ratio of 50%. Tensile response of SMA-FRP specimens were characterized under both monotonic loading and increasing amplitude loading and unloading cycles. The degradation in superelastic properties of the developed SMA-FRP composites during fatigue loading at different strain amplitudes was investigated. The effect of loading rate on the fatigue response of SMA-FRP composites was also explored. In addition, fractured specimens were examined using the scanning electron microscopy (SEM) technique to study the failure mechanisms of the tested specimens. A good interfacial bonding between the SMA strands and epoxy matrix was observed. The developed SMA-FRP composites exhibited good superelastic behavior at different strain amplitudes up to at least 800 cycle after which significant degradation occurred.

  5. Mechanical Properties of a Unidirectional Basalt-Fiber-Reinforced Plastic Under a Loading Simulating Operation Conditions

    NASA Astrophysics Data System (ADS)

    Lobanov, D. S.; Slovikov, S. V.

    2017-01-01

    The results of experimental investigations of unidirectional composites based on basalt fibers and different marks of epoxy resins are presented. Uniaxial tensile tests were carried out using a specimen fixation technique simulating the operation conditions of structures. The mechanical properties of the basalt-fiber-reinforced plastics (BFRPs) were determined. The diagrams of loading and deformation of BFRP specimens were obtain. The formulations of the composites with the highest mechanical properties were revealed.

  6. Using a surrogate contact pair to evaluate polyethylene wear in prosthetic knee joints.

    PubMed

    Sanders, Anthony P; Lockard, Carly A; Weisenburger, Joel N; Haider, Hani; Raeymaekers, Bart

    2016-01-01

    With recent improvements to the properties of ultra-high molecular weight polyethylene (UHMWPE) used in joint replacements, prosthetic knee and hip longevity may extend beyond two decades. However, it is difficult and costly to replicate such a long in vivo lifetime using clinically relevant in vitro wear testing approaches such as walking gait joint simulators. We advance a wear test intermediate in complexity between pin-on-disk and knee joint simulator tests. The test uses a surrogate contact pair, consisting of a surrogate femoral and tibial specimen that replicate the contact mechanics of any full-scale knee condyle contact pair. The method is implemented in a standard multi-directional pin-on-disk wear test machine, and we demonstrate its application via a two-million-cycle wear test of three different UHMWPE formulations. Further, we demonstrate the use of digital photography and image processing to accurately quantify fatigue damage based on the reduced transmission of light through a damage area in a UHMWPE specimen. The surrogate contact pairs replicate the knee condyle contact areas within -3% to +12%. The gravimetric wear test results reflect the dose of crosslinking radiation applied to the UHMWPE: 35 kGy yielded a wear rate of 7.4 mg/Mcycles, 55 kGy yielded 1.0 mg/Mcycles, and 75 kGy (applied to a 0.1% vitamin E stabilized UHMWPE) yielded 1.5 mg/Mcycles. A precursor to spalling fatigue is observed and precisely measured in the radiation-sterilized (35 kGy) and aged UHMWPE specimen. The presented techniques can be used to evaluate the high-cycle fatigue performance of arbitrary knee condyle contact pairs under design-specific contact stresses, using existing wear test machines. This makes the techniques more economical and well-suited to standardized comparative testing. © 2015 Wiley Periodicals, Inc.

  7. Design of a high-temperature experiment for evaluating advanced structural materials

    NASA Technical Reports Server (NTRS)

    Mockler, Theodore T.; Castro-Cedeno, Mario; Gladden, Herbert J.; Kaufman, Albert

    1992-01-01

    This report describes the design of an experiment for evaluating monolithic and composite material specimens in a high-temperature environment and subject to big thermal gradients. The material specimens will be exposed to aerothermal loads that correspond to thermally similar engine operating conditions. Materials evaluated in this study were monolithic nickel alloys and silicon carbide. In addition, composites such as tungsten/copper were evaluated. A facility to provide the test environment has been assembled in the Engine Research Building at the Lewis Research Center. The test section of the facility will permit both regular and Schlieren photography, thermal imaging, and laser Doppler anemometry. The test environment will be products of hydrogen-air combustion at temperatures from about 1200 F to as high as 4000 F. The test chamber pressure will vary up to 60 psia, and the free-stream flow velocity can reach Mach 0.9. The data collected will be used to validate thermal and stress analysis models of the specimen. This process of modeling, testing, and validation is expected to yield enhancements to existing analysis tools and techniques.

  8. Fatigue Characteristics of 3D Printed Acrylonitrile Butadiene Styrene (ABS)

    NASA Astrophysics Data System (ADS)

    Padzi, M. M.; Bazin, M. M.; Muhamad, W. M. W.

    2017-11-01

    Recently, the use of 3D printer technology has become significant to industries, especially when involving the new product development. 3D printing is a technology, which produces the 3D product or prototype using a layer-by-layer technique. However, there becomes less research on the mechanical performance of the 3D printed component. In the present work, fatigue characteristics of 3D printed specimen have been studied. Acrylonitrile butadiene styrene (ABS) has been chosen as a material research due to its wide applications. Two types of specimen used, which is the 3D printing and moulding specimens. Fused deposition modelling (FDM) technique was used to produce the specimens. The dog bone shape part was produced based on ASTM D638 standard and the tensile test has been carried out to get the mechanical properties. Fatigue test was carried out at 40%, 60% and 80% of the tensile strength. The moulded part shows higher fatigue cycles compared to 3D printed part for all loading percentages. Fatigue lives for 40%, 60% and 80%, were 911, 2645 and 26948 cycles, respectively. The results indicated that 3D printed part has a lower fatigue life, which may not suitable for industrial applications. However, the 3D printed part could be improved by using various parameters and may be introduced in low strength application.

  9. Laser and plasma dental soldering techniques applied to Ti-6Al-4V alloy: ultimate tensile strength and finite element analysis.

    PubMed

    Castro, Morgana G; Araújo, Cleudmar A; Menegaz, Gabriela L; Silva, João Paulo L; Nóbilo, Mauro Antônio A; Simamoto Júnior, Paulo Cézar

    2015-05-01

    The literature provides limited information regarding the performance of Ti-6Al-4V laser and plasma joints welded in prefabricated bars in dental applications. The purpose of this study was to evaluate the mechanical strength of different diameters of Ti-6Al-4V alloy welded with laser and plasma techniques. Forty-five dumbbell-shaped rods were created from Ti-6Al-4V and divided into 9 groups (n=5): a control group with 3-mm and intact bars; groups PL2.5, PL3, PL4, and PL5 (specimens with 2.5-, 3-, 4-, and 5-mm diameters welded with plasma); and groups L2.5, L3, L4, and L5 (specimens with 2.5-, 3-, 4-, and 5-mm diameters welded with laser). The specimens were tested for ultimate tensile strength (UTS), and elongation percentages (EP) were obtained. Fractured specimens were analyzed by stereomicroscopy, and welded area percentages (WAP) were calculated. Images were made with scanning electron microscopy. In the initial analysis, the data were analyzed with a 2-way ANOVA (2×4) and the Tukey Honestly Significant Difference (HSD) test. In the second analysis, the UTS and EP data were analyzed with 1-way ANOVA, and the Dunnett test was used to compare the 4 experimental groups with the control group (α=.05). The Pearson and Spearman correlation coefficient tests were applied to correlate the study factors. Finite element models were developed in a workbench environment with boundary conditions simulating those of a tensile test. The 2-way ANOVA showed that the factors welding type and diameter were significant for the UTS and WAP values. However, the interaction between them was not significant. The 1-way ANOVA showed statistically significant differences among the groups for UTS, WAP, and EP values. The Dunnett test showed that all the tested groups had lower UTS and EP values than the control group. The 2.5- and 3-mm diameter groups showed higher values for UTS and WAP than the other test groups. A positive correlation was found between welded area percentage and UTS and a negative correlation between these parameters and the diameters of the specimens. No statistically significant difference was found between the weld techniques. Under the experimental conditions described, diameters of 2.5 and 3 mm resulted in higher UTS and WAP for both laser and plasma welding and appear to be the best option for joining prefabricated rods in this kind of union. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  10. Laboratory diagnosis of invasive candidiasis.

    PubMed Central

    Jones, J M

    1990-01-01

    Severe infections due to Candida species have become more frequent during the past two decades because of the increasing numbers of immunosuppressed patients being treated in our hospitals. Distinguishing colonization from invasive disease requires knowledge of the pathogenetic mechanisms leading to invasion. To assist the clinician in therapeutic decisions, clinical microbiologists should identify to species Candida organisms isolated from immunosuppressed patients. Quantitative or semiquantitative cultures of urine, burn tissues, intravascular catheter tips, and bronchoalveolar lavage specimens may provide useful information. Immunofluorescent staining of certain specimens can enhance diagnostic yield. The lysis-centrifugation blood culture technique offers some advantages over traditional broth techniques in detecting Candida fungemia. Antibody testing is of limited diagnostic value in highly immunosuppressed patients. Developing simple and reliable tests for detecting antigens or metabolites of Candida spp. in the sera of infected patients has proven difficult. Methods for typing Candida albicans are evolving. Typing should prove useful for studying the epidemiology of candidiasis in hospitalized patients. Images PMID:2404567

  11. A study of elevated temperature testing techniques for the fatigue behavior of PMCS: Application to T650-35/AMB21

    NASA Technical Reports Server (NTRS)

    Gyekenyesi, Andrew L.; Gastelli, Michael G.; Ellis, John R.; Burke, Christopher S.

    1995-01-01

    An experimental study was conducted to investigate the mechanical behavior of a T650-35/AMB21 eight-harness satin weave polymer composite system. Emphasis was placed on the development and refinement of techniques used in elevated temperature uniaxial PMC testing. Issues such as specimen design, gripping, strain measurement, and temperature control and measurement were addressed. Quasi-static tensile and fatigue properties (R(sub sigma) = 0.1) were examined at room and elevated temperatures. Stiffness degradation and strain accumulation during fatigue cycling were recorded to monitor damage progression and provide insight for future analytical modeling efforts. Accomplishments included an untabbed dog-bone specimen design which consistently failed in the gage section, accurate temperature control and assessment, and continuous in-situ strain measurement capability during fatigue loading at elevated temperatures. Finally, strain accumulation and stiffness degradation during fatigue cycling appeared to be good indicators of damage progression.

  12. Comparison of mechanical characteristics of focused ion beam fabricated silicon nanowires

    NASA Astrophysics Data System (ADS)

    Ina, Ginnosuke; Fujii, Tatsuya; Kozeki, Takahiro; Miura, Eri; Inoue, Shozo; Namazu, Takahiro

    2017-06-01

    In this study, we investigate the effects of focused ion beam (FIB)-induced damage and specimen size on the mechanical properties of Si nanowires (NWs) by a microelectromechanical system (MEMS)-based tensile testing technique. By an FIB fabrication technique, three types of Si NWs, which are as-FIB-fabricated, annealed, and FIB-implanted NWs, are prepared. A sacrificial-oxidized NW is also prepared to compare the mechanical properties of these FIB-based NWs. The quasi-static uniaxial tensile tests of all the NWs are conducted by scanning electron microscopy (SEM). The fabrication process and specimen size dependences on Young’s modulus and fracture strength are observed. Annealing is effective for improving the Young’s modulus of the FIB-damaged Si. Transmission electron microscopy (TEM) suggests that the mechanism behind the process dependence on the mechanical characteristics is related to the crystallinity of the FIB-damaged portion.

  13. Piezoelectric Response of Ferroelectric Ceramics Under Mechanical Stress

    DTIC Science & Technology

    2015-09-17

    dynamic response, and predict mechanical breakdown of electronic materials, numerous testing techniques such as very high-g machines , drop towers...James C. Hierholzer for building the custom test fixture, Michael D. Craft for his help with static capacitance measurements, Bryan J. Turner, Scott D...ISOLA 370HR Board Specimen Test Set-Up . . . . . . . . . . . . . . . . . . 59 3.3 Printed Circuit Board Electrical Layout

  14. Fracture resistance of retreated roots using different retreatment systems.

    PubMed

    Er, Kursat; Tasdemir, Tamer; Siso, Seyda Herguner; Celik, Davut; Cora, Sabri

    2011-08-01

    This study was designed to evaluate the fracture resistance of retreated roots using different rotary retreatment systems. Forty eight freshly extracted human canine teeth with single straight root canals were instrumented sequentially increasing from size 30 to a size 55 using K-files whit a stepback technique. The teeth were randomly divided into three experimental and one control groups of 12 specimens each. The root canals were filled using cold lateral compaction of gutta-percha and AH Plus (Dentsply Detrey, Konstanz, Germany) sealer in experimental groups. Removal of gutta-percha was performed with the following devices and techniques: ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland), R-Endo (Micro-Mega, Besançon, France), and Mtwo (Sweden & Martina, Padova, Italy) rotary retreatment systems. Control group specimens were only instrumented, not filled or retreated. The specimens were then mounted in copper rings, were filled with a self-curing polymethylmethacrylate resin, and the force required to cause vertical root fracture was measured using a universal testing device. The force of fracture of the roots was recorded and the results in the various groups were compared. Statistical analysis was accomplished by one-way ANOVA and a post hoc Tukey tests. There were statistically significant differences between the control and experimental groups (P<.05). However, there were no significant differences among the experimental groups. Based on the results, all rotary retreatment techniques used in this in vitro study produced similar root weakness.

  15. Acoustic emission monitoring of tensile testing of corroded and un-corroded clad aluminum 2024-T3 and characterization of effects of corrosion on AE source events and material tensile properties

    NASA Astrophysics Data System (ADS)

    Okafor, A. Chukwujekwu; Natarajan, Shridhar

    2014-02-01

    Corrosion damage affects structural integrity and deteriorates material properties of aluminum alloys in aircraft structures. Acoustic Emission (AE) is an effective nondestructive evaluation (NDE) technique for monitoring such damages and predicting failure in large structures of an aircraft. For successful interpretation of data from AE monitoring, sources of AE and factors affecting it need to be identified. This paper presents results of AE monitoring of tensile testing of corroded and un-corroded clad Aluminum 2024-T3 test specimens, and characterization of the effects of strain-rate and corrosion damage on material tensile properties and AE source events. Effect of corrosion was studied by inducing corrosion in the test specimens by accelerated corrosion testing in a Q-Fog accelerated corrosion chamber for 12 weeks. Eight (8) masked dog-bone shaped specimens were placed in the accelerated corrosion chamber at the beginning of the test. Two (2) dog-bone shaped specimens were removed from the corrosion chamber after exposure time of 3, 6, 9, and 12 weeks respectively, and subjected to tension testing till specimen failure along with AE monitoring, as well as two (2) reference samples not exposed to corrosion. Material tensile properties (yield strength, ultimate tensile strength, toughness, and elongation) obtained from tension test and AE parameters obtained from AE monitoring were analyzed and characterized. AE parameters increase with increase in exposure period of the specimens in the corrosive environment. Aluminum 2024-T3 is an acoustically silent material during tensile deformation without any damage. Acoustic emission events increase with increase of corrosion damage and with increase in strain rate above a certain value. Thus AE is suitable for structural health monitoring of corrosion damage. Ultimate tensile strength, toughness and elongation values decrease with increase of exposure period in corrosion chamber.

  16. Comparative evaluation of tensile bond strength of silicone-based denture liners after thermocycling and surface treatment.

    PubMed

    Kaur, Harsimran; Datta, Kusum

    2015-01-01

    To examine, evaluate, and compare the tensile bond strength of two silicone-based liners; one autopolymerizing and one heat cured, when treated with different chemical etchants to improve their adhesion with denture base resin. Hundred and sixty test specimens of heat-cured polymethyl methacrylate (PMMA) were fabricated; out of which 80 specimens were tested for tensile bond strength after bonding it to autopolymerizing resilient liner (Ufigel P) and rest 80 to heat-cured resilient liner (Molloplast B). Each main group was further divided into four subgroups of 20 specimens each, one to act as a control and three were subjected to surface treatment with different chemical etchants namely dichloromethane, MMA monomer, and chloroform. The two silicone-based denture liners were processed between 2 PMMA specimens (10 mm × 10 mm × 40 mm) in the space provided by a spacer of 3 mm, thermocycled (5-55°C) for 500 cycles, and then their tensile strength measurements were done in the universal testing machine. One-way ANOVA technique showed a highly significant difference in the mean tensile bond strength values for all the groups. The Student's t-test computed values of statistics for the compared groups were greater than the critical values both at 5% and at 1% levels. Surface treatment of denture base resin with chemical etchants prior to the application of silicone-based liner (Ufigel P and Molloplast-B) increased the tensile bond strength. The increase was the highest with specimens subjected to 180 s of MMA surface treatment and the lowest with control group specimens.

  17. Biomechanical Comparison Study of Three Fixation Methods for Proximal Chevron Osteotomy of the First Metatarsal in Hallux Valgus

    PubMed Central

    Kim, Jin Su; Young, Ki Won; Kim, Ji Soo; Lee, Kyung Tai

    2017-01-01

    Background Fixation of proximal chevron metatarsal osteotomy has been accomplished using K-wires traditionally and with a locking plate recently. However, both methods have many disadvantages. Hence, we developed an intramedullary fixation technique using headless cannulated screws and conducted a biomechanical study to evaluate the superiority of the technique to K-wire and locking plate fixations. Methods Proximal chevron metatarsal osteotomy was performed on 30 synthetic metatarsal models using three fixation techniques. Specimens in group I were fixated with K-wires (1.6 mm × 2) and in group II with headless cannulated screws (3.0 mm × 2) distally through the intramedullary canal. Specimens in group III were fixated with a locking X-shaped plate (1.3-mm thick) and screws (2.5 mm × 4). Eight metatarsal specimens were selected from each group for walking fatigue test. Bending stiffness and dorsal angulation were measured by 1,000 repetitions of a cantilever bending protocol in a plantar to dorsal direction. The remaining two samples from each group were subjected to 5 mm per minute axial loading to assess the maximal loading tolerance. Results All samples in group I failed walking fatigue test while group II and group III tolerated the walking fatigue test. Group II showed greater resistance to bending force and smaller dorsal angulation than group III (p = 0.001). On the axial loading test, group I and group II demonstrated superior maximum tolerance to group III (54.8 N vs. 47.2 N vs. 28.3 N). Conclusions Authors have demonstrated proximal chevron metatarsal osteotomy with intramedullary screw fixation provides superior biomechanical stability to locking plate and K-wire fixations. The new technique using intramedullary screw fixation can offer robust fixation and may lead to better outcomes in surgical treatment of hallux valgus. PMID:29201305

  18. Mechanical characterization of an additively manufactured Inconel 718 theta-shaped specimen

    DOE PAGES

    Cakmak, Ercan; Watkins, Thomas R.; Bunn, Jeffrey R.; ...

    2015-11-20

    Two sets of “theta”-shaped specimens were additively manufactured with Inconel 718 powders using an electron beam melting technique with two distinct scan strategies. Light optical microscopy, mechanical testing coupled with a digital image correlation (DIC) technique, finite element modeling, and neutron diffraction with in situ loading characterizations were conducted. The cross-members of the specimens were the focus. Light optical micrographs revealed that different microstructures were formed with different scan strategies. Ex situ mechanical testing revealed each build to be stable under load until ductility was observed on the cross-members before failure. The elastic moduli were determined by forming a correlationmore » between the elastic tensile stresses determined from FEM, and the elastic strains obtained from DIC. The lattice strains were mapped with neutron diffraction during in situ elastic loading; and a good correlation between the average axial lattice strains on the cross-member and those determined from the DIC analysis was found. Lastly, the spatially resolved stresses in the elastic deformation regime are derived from the lattice strains and increased with applied load, showing a consistent distribution along the cross-member.« less

  19. Mechanical characterization of an additively manufactured Inconel 718 theta-shaped specimen

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cakmak, Ercan; Watkins, Thomas R.; Bunn, Jeffrey R.

    Two sets of “theta”-shaped specimens were additively manufactured with Inconel 718 powders using an electron beam melting technique with two distinct scan strategies. Light optical microscopy, mechanical testing coupled with a digital image correlation (DIC) technique, finite element modeling, and neutron diffraction with in situ loading characterizations were conducted. The cross-members of the specimens were the focus. Light optical micrographs revealed that different microstructures were formed with different scan strategies. Ex situ mechanical testing revealed each build to be stable under load until ductility was observed on the cross-members before failure. The elastic moduli were determined by forming a correlationmore » between the elastic tensile stresses determined from FEM, and the elastic strains obtained from DIC. The lattice strains were mapped with neutron diffraction during in situ elastic loading; and a good correlation between the average axial lattice strains on the cross-member and those determined from the DIC analysis was found. Lastly, the spatially resolved stresses in the elastic deformation regime are derived from the lattice strains and increased with applied load, showing a consistent distribution along the cross-member.« less

  20. A new anchor augmentation technique with a cancellous screw in osteoporotic rotator cuff repair: an in vitro biomechanical study on sheep humerus specimens.

    PubMed

    Uruc, Vedat; Ozden, Raif; Dogramacı, Yunus; Kalacı, Aydıner; Hallaceli, Hasan; Küçükdurmaz, Fatih

    2014-01-01

    The aim of this study was to test a simple technique to augment the pullout resistance of an anchor in an over-drilled sheep humerus model. Sixty-four paired sheep humeri were harvested from 32 male sheep aged 18 months. Specimens were divided into an augmented group and non-augmented group. FASTIN RC 5-mm titanium screw anchors (DePuy Mitek, Raynham, MA) double loaded with suture material (braided polyester, nonabsorbable USP No. 2) were used in both groups. Osteoporosis was simulated by over-drilling with a 4.5-mm drill. Augmentation was performed by fixing 1 of the sutures 1.5 cm inferior to the anchor insertion site with a washer screw. This was followed by a pull-to-failure test at 50 mm/min. The ultimate load (the highest value of strength before anchor pullout) was recorded. A paired t test was used to compare the biomechanical properties of the augmented and non-augmented groups. In all specimens the failure mode was pullout of the anchor. The ultimate failure loads were statistically significantly higher in the augmented group (P < .0001). The mean pullout strength was 121.1 ± 10.17 N in the non-augmented group and 176.1 ± 10.34 N in the augmented group. The described augmentation technique, which is achieved by inferior-lateral fixation of 1 of the sutures of the double-loaded anchor to a fully threaded 6.5-mm cancellous screw with a washer, significantly increases the ultimate failure loads in the over-drilled sheep humerus model. Our technique is simple, safe, and inexpensive. It can be easily used in all osteoporotic patients and will contribute to the reduction of anchor failure. This technique might be difficult to apply arthroscopically. Cannulated smaller screws would probably be more practical for arthroscopic use. Further clinical studies are needed. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  1. Effectiveness of saliva and fingerprints as alternative specimens to urine and blood in forensic drug testing.

    PubMed

    Kuwayama, Kenji; Miyaguchi, Hajime; Yamamuro, Tadashi; Tsujikawa, Kenji; Kanamori, Tatsuyuki; Iwata, Yuko T; Inoue, Hiroyuki

    2016-07-01

    In forensic drug testing, it is important to immediately take biological specimens from suspects and victims to prove their drug intake. We evaluated the effectiveness of saliva and fingerprints as alternative specimens to urine and blood in terms of ease of sampling, drug detection sensitivity, and drug detection periods for each specimen type. After four commercially available pharmaceutical products were administered to healthy subjects, each in a single dose, their urine, blood, saliva, and fingerprints were taken at predetermined sampling times over approximately four weeks. Fourteen analytes (the administered drugs and their main metabolites) were extracted from each specimen using simple pretreatments, such as dilution and deproteinization, and were analyzed using liquid chromatography/mass spectrometry (LC/MS). Most of the analytes were detected in saliva and fingerprints, as well as in urine and blood. The time-courses of drug concentrations were similar between urine and fingerprints, and between blood and saliva. Compared to the other compounds, the acidic compounds, for example ibuprofen, acetylsalicylic acid, were more difficult to detect in all specimens. Acetaminophen, dihydrocodeine, and methylephedrine were detected in fingerprints at later sampling times than in urine. However, a relationship between the drug structures and their detection periods in each specimen was not found. Saliva and fingerprints could be easily sampled on site without using special techniques or facilities. In addition, fingerprints could be immediately analyzed after simple and rapid treatment. In cases where it would be difficult to immediately obtain urine and blood, saliva and fingerprints could be effective alternative specimens for drug testing. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  2. Bonding of universal adhesives to dentine--Old wine in new bottles?

    PubMed

    Chen, C; Niu, L-N; Xie, H; Zhang, Z-Y; Zhou, L-Q; Jiao, K; Chen, J-H; Pashley, D H; Tay, F R

    2015-05-01

    Multi-mode universal adhesives offer clinicians the choice of using the etch-and-rinse technique, selective enamel etch technique or self-etch technique to bond to tooth substrates. The present study examined the short-term in vitro performance of five universal adhesives bonded to human coronal dentine. Two hundred non-carious human third molars were assigned to five groups based on the type of the universal adhesives (Prime&Bond Elect, Scotchbond Universal, All-Bond Universal, Clearfil Universal Bond and Futurabond U). Two bonding modes (etch-and-rinse and self-etch) were employed for each adhesive group. Bonded specimens were stored in deionized water for 24h or underwent a 10,000-cycle thermocycling ageing process prior to testing (N=10). Microtensile bond testing (μTBS), transmission electron microscopy (TEM) of resin-dentine interfaces in non-thermocycled specimens and scanning electron microscopy (SEM) of tracer-infused water-rich zones within hybrid layers of thermocycled specimens were performed. Both adhesive type and testing condition (with/without thermocycling) have significant influences on μTBS. The use of each adhesive in either the etch-and-rinse or self-etch application mode did not result in significantly different μTBS to dentine. Hybrid layers created by these adhesives in the etch-and-rinse bonding mode and self-etch bonding mode were ∼5μm and ≤0.5μm thick respectively. Tracer-infused regions could be identified within the resin-dentine interface from all the specimens prepared. The increase in versatility of universal adhesives is not accompanied by technological advances for overcoming the challenges associated with previous generations of adhesives. Therapeutic adhesives with bio-protective and bio-promoting effects are still lacking in commercialized adhesives. Universal adhesives represent manufacturers' attempt to introduce versatility in product design via adaptation of a single-bottle self-etch adhesive for other application modes without compromising its bonding effectiveness. Published by Elsevier Ltd.

  3. High-Tensile Strength Tape Versus High-Tensile Strength Suture: A Biomechanical Study.

    PubMed

    Gnandt, Ryan J; Smith, Jennifer L; Nguyen-Ta, Kim; McDonald, Lucas; LeClere, Lance E

    2016-02-01

    To determine which suture design, high-tensile strength tape or high-tensile strength suture, performed better at securing human tissue across 4 selected suture techniques commonly used in tendinous repair, by comparing the total load at failure measured during a fixed-rate longitudinal single load to failure using a biomechanical testing machine. Matched sets of tendon specimens with bony attachments were dissected from 15 human cadaveric lower extremities in a manner allowing for direct comparison testing. With the use of selected techniques (simple Mason-Allen in the patellar tendon specimens, whip stitch in the quadriceps tendon specimens, and Krackow stitch in the Achilles tendon specimens), 1 sample of each set was sutured with a 2-mm braided, nonabsorbable, high-tensile strength tape and the other with a No. 2 braided, nonabsorbable, high-tensile strength suture. A total of 120 specimens were tested. Each model was loaded to failure at a fixed longitudinal traction rate of 100 mm/min. The maximum load and failure method were recorded. In the whip stitch and the Krackow-stitch models, the high-tensile strength tape had a significantly greater mean load at failure with a difference of 181 N (P = .001) and 94 N (P = .015) respectively. No significant difference was found in the Mason-Allen and simple stitch models. Pull-through remained the most common method of failure at an overall rate of 56.7% (suture = 55%; tape = 58.3%). In biomechanical testing during a single load to failure, high-tensile strength tape performs more favorably than high-tensile strength suture, with a greater mean load to failure, in both the whip- and Krackow-stitch models. Although suture pull-through remains the most common method of failure, high-tensile strength tape requires a significantly greater load to pull-through in a whip-stitch and Krakow-stitch model. The biomechanical data obtained in the current study indicates that high-tensile strength tape may provide better repair strength compared with high-tensile strength suture at time-zero simulated testing. Published by Elsevier Inc.

  4. Post-Impact and Open Hole Tensile Of Kenaf Hybrid Composites

    NASA Astrophysics Data System (ADS)

    Yunus, S.; Salleh, Z.; Masdek, N. R. N. M.; Taib, Y. M.; Azhar, I. I. S.; Hyie, K. M.

    2018-03-01

    Nowadays, kenaf hybrid glass composites has been used for a vast field of study throughout the globe. There are several compositions and orientation of kenaf hybrid glass composites that has been studied. With regards to the study that has been done, this study will be focussing on a 90FG/0/90/90/0/90FG orientation of kenaf hybrid glass composites. Polyester resin is used as a matrix to these hybrid composites. Impacted and open hole specimens were then analyzed through tensile test. All specimens were fabricated by using the cold press hand lay-up technique. The results revealed that the hybrid composites were hardly affected by the impact up to 6J. After 6J the impacted specimens experienced a significant damage for both strength and modulus. The same goes to open hole specimens where the same trend of tensile properties were observed as impacted specimens.

  5. Lens-free shadow image based high-throughput continuous cell monitoring technique.

    PubMed

    Jin, Geonsoo; Yoo, In-Hwa; Pack, Seung Pil; Yang, Ji-Woon; Ha, Un-Hwan; Paek, Se-Hwan; Seo, Sungkyu

    2012-01-01

    A high-throughput continuous cell monitoring technique which does not require any labeling reagents or destruction of the specimen is demonstrated. More than 6000 human alveolar epithelial A549 cells are monitored for up to 72 h simultaneously and continuously with a single digital image within a cost and space effective lens-free shadow imaging platform. In an experiment performed within a custom built incubator integrated with the lens-free shadow imaging platform, the cell nucleus division process could be successfully characterized by calculating the signal-to-noise ratios (SNRs) and the shadow diameters (SDs) of the cell shadow patterns. The versatile nature of this platform also enabled a single cell viability test followed by live cell counting. This study firstly shows that the lens-free shadow imaging technique can provide a continuous cell monitoring without any staining/labeling reagent and destruction of the specimen. This high-throughput continuous cell monitoring technique based on lens-free shadow imaging may be widely utilized as a compact, low-cost, and high-throughput cell monitoring tool in the fields of drug and food screening or cell proliferation and viability testing. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Revealing Slip Bands In A Metal-Matrix/Fiber Composite

    NASA Technical Reports Server (NTRS)

    Lerch, Bradley A.

    1995-01-01

    Experimental procedure includes heat treatments and metallographic techniques developed to facilitate studies of deformation of metal-matrix/fiber composite under stress. Reveals slip bands, indicative of plastic flow occurring in matrix during mechanical tests of specimens of composite.

  7. Comparative evaluation of the amount of the residual monomer in conventional and deep-frozen heat cure polymethylmethacrylate acrylic resin: An in vitro study.

    PubMed

    Jadhav, Sonali S; Mahajan, Neerja; Sethuraman, Rajesh

    2018-01-01

    Heat cure acrylic resin material with reduced monomer content is generally recommended for clinical usage as it leads to improved mechanical, physical, and biocompatibility properties. The purpose of the present study was to evaluate and compare the amount of the residual monomer in the conventional and three different groups of deep-frozen heat cure polymethylmethacrylate (PMMA) acrylic resin. Totally 40 Specimens of heat cure PMMA acrylic resin (DPI India) (10 conventional heat cure and 30 deep frozen) were made using two disc-shaped stainless steel molds and invested into type II dental stone using compression molding technique. Each group contained 10 specimens ( n = 10). Group 1: Control group of conventional polished PMMA specimen stored in water for 24 h at +37°C (10 specimens), Group 2: Deep frozen unpolished PMMA (10 specimens), Group 3: Deep frozen polished PMMA (10 specimens), and Group 4: Deep frozen polished PMMA specimen stored in water for 24 h at +37°C (10 specimens). Amount of the residual monomer content in all the specimens was measured using high-performance liquid chromatography. Data were analyzed using One-Way Analysis of Variance and multiple comparison Tukey's post hoc test (α = 0.05). Least residual monomer content was found in Group 4 (0.12 wt%) followed by Group 3 (0.19 wt%), Group 2 (0.23 wt%), and Group 1 (0.26 wt%). Statistically significant difference ( P < 0.05) was found in residual monomer content for all the four groups tested. Post hoc test for intergroup comparison also showed a significant difference between groups. The amount of the residual monomer was found to be least in deep-frozen polished PMMA specimen stored in water for 24 h at +37°C (Group 4). Thus, it can be concluded that deep freezing, polishing, and storing in water can reduce the residual monomer content.

  8. Verification of rain-flow reconstructions of a variable amplitude load history. M.S. Thesis, 1990 Final Report

    NASA Technical Reports Server (NTRS)

    Clothiaux, John D.; Dowling, Norman E.

    1992-01-01

    The suitability of using rain-flow reconstructions as an alternative to an original loading spectrum for component fatigue life testing is investigated. A modified helicopter maneuver history is used for the rain-flow cycle counting and history regenerations. Experimental testing on a notched test specimen over a wide range of loads produces similar lives for the original history and the reconstructions. The test lives also agree with a simplified local strain analysis performed on the specimen utilizing the rain-flow cycle count. The rain-flow reconstruction technique is shown to be a viable test spectrum alternative to storing the complete original load history, especially in saving computer storage space and processing time. A description of the regeneration method, the simplified life prediction analysis, and the experimental methods are included in the investigation.

  9. Prediction of failure pressure and leak rate of stress corrosion.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Majumdar, S.; Kasza, K.; Park, J. Y.

    2002-06-24

    An ''equivalent rectangular crack'' approach was employed to predict rupture pressures and leak rates through laboratory generated stress corrosion cracks and steam generator tubes removed from the McGuire Nuclear Station. Specimen flaws were sized by post-test fractography in addition to a pre-test advanced eddy current technique. The predicted and observed test data on rupture and leak rate are compared. In general, the test failure pressures and leak rates are closer to those predicted on the basis of fractography than on nondestructive evaluation (NDE). However, the predictions based on NDE results are encouraging, particularly because they have the potential to determinemore » a more detailed geometry of ligamented cracks, from which failure pressure and leak rate can be more accurately predicted. One test specimen displayed a time-dependent increase of leak rate under constant pressure.« less

  10. Microleakage and shear punch bond strength in class II primary molars cavities restored with low shrink silorane based versus methacrylate based composite using three different techniques.

    PubMed

    Fahmy, Amal Ezzeldin; Farrag, Nadia Moustafa

    2010-01-01

    This in vitro study aimed to evaluate the gingival microleakage in class II cavities in primary molars restored with a low shrink silorane resin composite (Filtek P90) or a nanohybride composite resin (Filtek supreme XT) using three different techniques, (total bonding, closed or open sandwich techniques) lined by nano-filled resin modified glass ionomer cement RMGIC (Ketac N100). Additionally, the shear punch bond strength between the two types of composite and KNIO0 was also examined. For microleakage test, two standardized class II slot cavities were prepared in proximal surfaces of 60 sound extracted primary molars which were divided into 2 groups of 30 each according to the type of composite. Each group was subdivided into 3 groups (n = 10) according to the restorative technique used. The restored teeth were examined for microleakage after immersion in 2% methylene blue dye using stereomicroscope at 20 X. Microleakage scores among the groups were compared using Kruskal Wallis test followed by pair wise Mann Whitney U test at P < or = 0.05. Thirty disc specimens were prepared for determining the shear punch bond strength between the two composite materials and the KN100. Specimens were divided into 5 groups (n = 6) according to the adhesive protocol. The differences in mean bond strength values in MPa between groups were statistically analyzed using ANOVA followed by pair wise Tukey Post hoc test at P < or = 0. 05. Mode of failure was also evaluated for all groups. Both the silorane resin and nano-composite resin showed superior marginal seal with the total bonding technique compared to closed and open sandwich techniques. The recorded mean shear punch bond strength values showed no statistical significant difference between the two resin composites without or with their adhesive bonding systems when bonded to the nano-ionomer. All specimens showed cohesive mode of failures except for silorane resin with Adper Easy Bond Self Etch Adhesive (AEBSEA) which showed adhesive mode of failure. The best marginal seal was obtained with the total bonding technique using both resin composites. The shear punch bond strength between KN100 and the two composite materials was not affected by either of the used adhesive bonding agent.

  11. Characterization of Cold Sprayed CuCrAl-Coated and Uncoated GRCop-84 Substrates for Space Launch Vehicles

    NASA Technical Reports Server (NTRS)

    Raj, S. V.; Karthikeyan, J.; Lerch, B. A.; Barrett, C.; Garlich, R.

    2007-01-01

    A newly developed Cu-23(wt.%)Cr-5%Al (CuCrAl) alloy is currently being considered as a protective coating for GRCop-84 (Cu-8(at.%)Cr-4%Nb). The coating was deposited on GRCop-84 substrates by the cold spray deposition technique. Cyclic oxidation tests conducted in air on both coated and uncoated substrates between 773 and 1073 K revealed that the coating remained intact and protected the substrate up to 1073 K. No significant weight loss of the coated specimens were observed at 773 and 873 K even after a cumulative cyclic time of 500 h. In contrast, the uncoated substrate lost as much as 80% of its original weight under similar test conditions. Low cycle fatigue tests revealed that the fatigue lives of thinly coated GRCop-84 specimens were similar to the uncoated specimens within the limits of experimental scatter. It is concluded that the cold sprayed CuCrAl coating is suitable for protecting GRCop-84 substrates.

  12. 1000537

    NASA Image and Video Library

    2010-04-13

    NATHAN HORACE STRONG (AEROSPACE ENGINEER, ER31 PROPULSION TURBOMACHINERY DESIGN & DEVELOPMENT BRANCH) AND NATHAN COFFEE (EM10 MATERIALS TEST ENGINEER, JACOBS ESTS GROUP/JTI) ADJUST A UNIQUE MECHANICAL TEST SETUP THAT MEASURES STRAIN ON A SINGLE SAMPLE, USING TWO DIFFERENT TECHNIQUES AT THE SAME TIME. THE TEST FIXTURE HOLDS A SPECIMEN THAT REPRESENTS A LIQUID OXYGEN (LOX) BEARING FROM THE J2-X ENGINE. COFFEY, AT RIGHT, WORK IN A LAB IN BUILDING 4612 ON A BEARING TEST

  13. An improved method for isolating viruses from asymptomatic carrier fish

    USGS Publications Warehouse

    Amend, Donald F.; Pietsch, John P.

    1972-01-01

    This paper describes a method using elevated levels of penicillin, streptomycin, and nystatin instead of filters to control bacteria and mold contaminants in specimens processed for virus isolation. Filters were shown to significantly reduce the virus concentration. Virus and tissue cultures were not affected by this procedure. In field tests nearly three times more specimens were positive for virus with this method than with the widely used filter technique. Moreover, the cost of materials was less. This method is recommended for inspection and certification purposes.

  14. Influences of strain rate on yield strength aluminum alloys

    NASA Astrophysics Data System (ADS)

    Rizal, Samsul; Firdaus, Hamdani Teuku; Thaib, Razali; Homma, Hiroomi

    2005-04-01

    The simulation of aircraft has often been performing by implementing finite element code on supercomputers. The reliability an accuracy of simulation depends mainly on the material model as well as on structural model used in calculations. Consequently, an accurate knowledge of mechanical behavior of materials under impact loading is essential for safety performance evaluation of structure. Impact tension tests on specimens for aircrafts and automotive structural applications are conduct by means of the split Hopkinson bar apparatus. Small specimens having diameter 4 mm are use in the test. Tensile stress-strain relations at strain rates of 102 s-1 to over 103 s-1 are present and compared with those obtained at quasi-static strain rates. The limitations on the applicability of apparatus are also discusses. The other importance of the reference of strain, while studying void growth in elastic-viscoplastic material, is emphasized. In the present paper, a simplified plane-symmetrical two-dimensional finite element model for a SHPB with a plate specimen made of an elastic material is first established. The used of strain gage mounted at the specimens to be monitored strain during the course of impact test. Comparisons may then be made between the numerical predicted and experimentally observed of load and a specimen strain. This report also describes the apparatus and instrumentation, and also be discusses the advantages and limitations of experimental technique. Fractograph is taken by scanning electron microscope on the center of the specimens for judgment of the fracture mechanism and strain rates influences on the materials.

  15. Comparison of microstructure and mechanical properties of ultra-narrow gap laser and gas-metal-arc welded S960 high strength steel

    NASA Astrophysics Data System (ADS)

    Guo, Wei; Li, Lin; Dong, Shiyun; Crowther, Dave; Thompson, Alan

    2017-04-01

    The microstructural characteristics and mechanical properties, including micro-hardness, tensile properties, three-point bending properties and Charpy impact toughness at different test temperatures of 8 mm thick S960 high strength steel plates were investigated following their joining by multi-pass ultra-narrow gap laser welding (NGLW) and gas metal arc welding (GMAW) techniques. It was found that the microstructure in the fusion zone (FZ) for the ultra-NGLW joint was predominantly martensite mixed with some tempered martensite, while the FZ for the GMAW joint was mainly consisted of ferrite with some martensite. The strength of the ultra-NGLW specimens was comparable to that of the base material (BM), with all welded specimens failed in the BM in the tensile tests. The tensile strength of the GMAW specimens was reduced approximately by 100 MPa when compared with the base material by a broad and soft heat affected zone (HAZ) with failure located in the soft HAZ. Both the ultra-NGLW and GMAW specimens performed well in three-point bending tests. The GMAW joints exhibited better impact toughness than the ultra-NGLW joints.

  16. Results of inphase axial-torsional fatigue experiments on 304 stainless steel

    NASA Technical Reports Server (NTRS)

    Bonacuse, Peter J.; Kalluri, Sreeramesh

    1989-01-01

    A series of axial-torsional, inphase, strain-controlled, low-cycle fatigue tests were performed at room temperature on tubular specimens of 304 stainless steel. The program was conducted in cooperation with the task group on multiaxial fatigue research of ASTM committee E-09. The objective was to quantify the variability in multiaxial test results among several laboratories. Only included is data which was generated at the NASA Lewis Research Center's High Temperature Fatigue and Structures Laboratory. The experimental equipment and procedures used are described. The tubular specimens were polished on the outer surface to aid in the use of a cellulose film surface replication technique for crack detection. However, cracking initiated predominantly on the internal surface for all specimens. Honing of the bore of the tubular specimens lessened but did not entirely eliminate this problem. The observed fatigue lives are compared with lives calculated from three multiaxial life models. Constants for the life prediction models were obtained from uniaxial and torsional tests performed on the same heat of material. The observed fatigue lives agreed with calculated lives to within a factor of two for all but one of the life prediction models.

  17. Acoustic emission monitoring of low velocity impact damage in graphite/epoxy laminates during tensile loading

    NASA Technical Reports Server (NTRS)

    Parker, Bradford H.

    1992-01-01

    An acoustic emission (AE) system was set up in a linear location data acquisition mode to monitor the tensile loading of eight-ply quasi-isotropic graphite/epoxy specimens containing low velocity impact damage. The impact damage was induced using an instrumented drop weight tower. During impact, specimens were supported by either an aluminum plate or a membrane configuration. Cross-sectional examinations revealed that the aluminum plate configuration resulted in primarily matrix cracking and back surface fiber failure. The membrane support resulted in only matrix cracking and delamination damage. Penetrant enhanced radiography and immersion ultrasonics were used in order to assess the amount of impact damage in each tensile specimen. During tensile loading, AE reliably detected and located the damage sites which included fiber failure. All specimens with areas of fiber breakage ultimately failed at the impact site. AE did not reliably locate damage which consisted of only delaminations and matrix cracking. Specimens with this type of damage did not ultimately fail at the impact site. In summary, AE demonstrated the ability to increase the reliability of structural proof tests; however, the successful use of this technique requires extensive baseline testing.

  18. High-impact strength acrylic denture base material processed by autoclave.

    PubMed

    Abdulwahhab, Salwan Sami

    2013-10-01

    To investigate the effect of two different cycles of autoclave processing on the transverse strength, impact strength, surface hardness and the porosity of high-impact strength acrylic denture base material. High Impact Acryl was the heat-cured acrylic denture base material included in the study. A total of 120 specimens were prepared, the specimens were grouped into: control groups in which high-impact strength acrylic resins processed by conventional water-bath processing technique (74°C for 1.5 h then boil for 30 min) and experimental groups in which high-impact strength acrylic resins processed by autoclave at 121°C, 210 kPa .The experimental groups were divided into (fast) groups for 15 min, and (slow) groups for 30 min. To study the effect of the autoclave processing (Tuttnauer 2540EA), four tests were conducted transverse strength (Instron universal testing machine), impact strength (Charpy tester), surface hardness (shore D), and porosity test. The results were analyzed to ANOVA and LSD test. In ANOVA test, there were highly significant differences between the results of the processing techniques in transverse, impact, hardness, and porosity test. The LSD test showed a significant difference between control and fast groups in transverse and hardness tests and a non-significant difference in impact test and a highly significant difference in porosity test; while, there were a highly significant differences between control and slow groups in all examined tests; finally, there were a non-significant difference between fast and slow groups in transverse and porosity tests and a highly significant difference in impact and hardness tests. In the autoclave processing technique, the slow (long) curing cycle improved the tested physical and mechanical properties as compared with the fast (short) curing cycle. The autoclave processing technique improved the tested physical and mechanical properties of High Impact Acryl. Copyright © 2013 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  19. Evaluation of metal-ceramic bond characteristics of three dental Co-Cr alloys prepared with different fabrication techniques.

    PubMed

    Wang, Hongmei; Feng, Qing; Li, Ning; Xu, Sheng

    2016-12-01

    Limited information is available regarding the metal-ceramic bond strength of dental Co-Cr alloys fabricated by casting (CAST), computer numerical control (CNC) milling, and selective laser melting (SLM). The purpose of this in vitro study was to evaluate the metal-ceramic bond characteristics of 3 dental Co-Cr alloys fabricated by casting, computer numerical control milling, and selective laser melting techniques using the 3-point bend test (International Organization for Standardization [ISO] standard 9693). Forty-five specimens (25×3×0.5 mm) made of dental Co-Cr alloys were prepared by CAST, CNC milling, and SLM techniques. The morphology of the oxidation surface of metal specimens was evaluated by scanning electron microscopy (SEM). After porcelain application, the interfacial characterization was evaluated by SEM equipped with energy-dispersive spectrometry (EDS) analysis, and the metal-ceramic bond strength was assessed with the 3-point bend test. Failure type and elemental composition on the debonding interface were assessed by SEM/EDS. The bond strength was statistically analyzed by 1-way ANOVA and Tukey honest significant difference test (α=.05). The oxidation surfaces of the CAST, CNC, and SLM groups were different. They were porous in the CAST group but compact and irregular in the CNC and SLM groups. The metal-ceramic interfaces of the SLM and CNC groups showed excellent combination compared with those of the CAST group. The bond strength was 37.7 ±6.5 MPa for CAST, 43.3 ±9.2 MPa for CNC, and 46.8 ±5.1 MPa for the SLM group. Statistically significant differences were found among the 3 groups tested (P=.028). The debonding surfaces of all specimens exhibited cohesive failure mode. The oxidation surface morphologies and thicknesses of dental Co-Cr alloys are dependent on the different fabrication techniques used. The bond strength of all 3 groups exceed the minimum acceptable value of 25 MPa recommended by ISO 9693; hence, dental Co-Cr alloy fabricated with the SLM techniques could be a promising alternative for metal ceramic restorations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. The Impact Response of Carbon/Epoxy Laminates (Center Director's Discretionary Fund, Project No. 94-13)

    NASA Technical Reports Server (NTRS)

    Nettles, A. T.; Hodge, A. J.

    1997-01-01

    Low velocity dropweight impact tests were conducted on carbon/epoxy laminates under various boundary conditions. The composite plates were 8-ply (+45,0,-45,90)s laminates supported in a clamped-clamped/free-free configuration with varying amounts of in-plane load, N(sub x), applied. Specimens were impacted at energies of 3.4, 4.5, and 6 Joules (2.5, 3.3, and 4.4 ft-lb). The amount of damage induced into the specimen was evaluated using instrumented impact techniques, x-ray inspection, and cross-sectional photomicroscopy. Some static identation tests were performed to examine if the impact events utilized in this study were of a quasi-static nature and also to gain insight into the shape of the deflected surface at various impact load combinations. Load-displacement curves from these tests were compared to those of the impact tests, as was damage determined from x-ray inspection. The finite element technique was used to model the impact event and determine the stress field within the laminae. Results showed that for a given impact energy level, more damage was induced into the specimen as the external in-plane load, N(sub x), was increased. The majority of damage observed consisted of back face splitting of the matrix parallel to the fibers in that ply, associated with delaminations emanating from these splits. The analysis showed qualitatively the results of impact conditions on maximum load of impact, maximum transverse deflection, and first failure mode and location.

  1. Corrosion Analysis of TiCN Coated Al-7075 Alloy for Marine Applications: A Case Study

    NASA Astrophysics Data System (ADS)

    Srinath, M. K.; Ganesha Prasad, M. S.

    2018-05-01

    Corrosion is one of the most important marine difficulties that cause long term problems, occurring in ships and submarines surrounded by a corrosive environment when coupled with chemical, temperature and stress related conditions. Corrosion of marine parts could lead to severe disasters. Coatings and heat treatment in a very effective way could be used to protect the aluminium parts against corrosion. The present case study focuses on the corrosion and microstructural properties of TiCN coatings fabricated on Al-7075 aluminium alloy substrate by using Physical Vapour Deposition technique. Corrosion properties of specimen's heat treated at 500 °C at durations of 1, 4, 8 and 12 h were tested through salt spray test. According to D-1193, ASTM standard, corrosion resistance of coated and heat treated Al-7075 samples were investigated in solution kept at 95 °F with a pH of 6.5-7.2, with 5 sections of NaCl to 95 sections of type IV water. The specimen's heat treated for 1 h showed positive corrosion resistance, while the specimens treated for longer durations had the opposite effect. The microstructures of the salt spray tested coatings were investigated by scanning electron microscope. X-ray diffraction tests were conducted on specimens to determine the atomic and molecular structure of the surface crystals and the unit cell dimensions. The corrosion mechanisms of the coated specimens under the heat treated conditions have been explored.

  2. Accelerating plant DNA barcode reference library construction using herbarium specimens: improved experimental techniques.

    PubMed

    Xu, Chao; Dong, Wenpan; Shi, Shuo; Cheng, Tao; Li, Changhao; Liu, Yanlei; Wu, Ping; Wu, Hongkun; Gao, Peng; Zhou, Shiliang

    2015-11-01

    A well-covered reference library is crucial for successful identification of species by DNA barcoding. The biggest difficulty in building such a reference library is the lack of materials of organisms. Herbarium collections are potentially an enormous resource of materials. In this study, we demonstrate that it is likely to build such reference libraries using the reconstructed (self-primed PCR amplified) DNA from the herbarium specimens. We used 179 rosaceous specimens to test the effects of DNA reconstruction, 420 randomly sampled specimens to estimate the usable percentage and another 223 specimens of true cherries (Cerasus, Rosaceae) to test the coverage of usable specimens to the species. The barcode rbcLb (the central four-sevenths of rbcL gene) and matK was each amplified in two halves and sequenced on Roche GS 454 FLX+. DNA from the herbarium specimens was typically shorter than 300 bp. DNA reconstruction enabled amplification fragments of 400-500 bp without bringing or inducing any sequence errors. About one-third of specimens in the national herbarium of China (PE) were proven usable after DNA reconstruction. The specimens in PE cover all Chinese true cherry species and 91.5% of vascular species listed in Flora of China. It is very possible to build well-covered reference libraries for DNA barcoding of vascular species in China. As exemplified in this study, DNA reconstruction and DNA-labelled next-generation sequencing can accelerate the construction of local reference libraries. By putting the local reference libraries together, a global library for DNA barcoding becomes closer to reality. © 2015 John Wiley & Sons Ltd.

  3. Accurate characterization of wafer bond toughness with the double cantilever specimen

    NASA Astrophysics Data System (ADS)

    Turner, Kevin T.; Spearing, S. Mark

    2008-01-01

    The displacement loaded double cantilever test, also referred to as the "Maszara test" and the "crack opening method" by the wafer bonding community, is a common technique used to evaluate the interface toughness or surface energy of direct wafer bonds. While the specimen is widely used, there has been a persistent question as to the accuracy of the method since the actual specimen geometry differs from the ideal beam geometry assumed in the expression used for data reduction. The effect of conducting the test on whole wafer pairs, in which the arms of cantilevers are wide plates rather than slender beams, is examined in this work using finite element analysis. A model is developed to predict the equilibrium shape of the crack front and to develop a corrected expression for calculating interface toughness from crack length measurements obtained in tests conducted on whole wafer pairs. The finite element model, which is validated through comparison to experiments, demonstrates that using the traditional beam theory-based expressions for data reduction can lead to errors of up to 25%.

  4. Indentation fracture toughness and dynamic elastic moduli for commercial feldspathic dental porcelain materials.

    PubMed

    Rizkalla, Amin S; Jones, Derek W

    2004-02-01

    The purpose of this study was to evaluate and compare the indentation fracture toughness, true hardness and dynamic elastic moduli for 14 commercial dental porcelain materials. The specimens were fired according to manufacturer instructions. The density of the specimens (n=3) was measured by means of the water displacement technique. Dynamic Young's shear and bulk moduli and Poisson's ratio (n=3) were measured using a non-destructive ultrasonic technique using 10 MHz lithium niobate crystals. The true hardness (n=3) was measured using a Knoop indenter and the fracture toughness (n=3) was determined using a Vickers indenter and a Tukon hardness tester. Statistical analysis of the data was conducted using ANOVA and a Student-Newman-Keuls (SNK) rank order multiple comparative test. The SNK rank test analysis for the mean dynamic Young's modulus and fracture toughness was able to separate 14 dental porcelain materials into seven and nine groups, respectively, at p=0.05. The elastic moduli, true hardness and indentation fracture toughness for opaque porcelains were significantly higher than incisal; and body materials at p=0.05. The indentation fracture toughness and the ultrasonic test methods exhibit lower coefficient of variation compared to conventional methods and have considerable advantage for ceramic dental materials in that only small specimens are required to produce an acceptable number of data for statistical analysis.

  5. Compaction behavior of surrogate degraded emplaced WIPP waste.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Broome, Scott Thomas; Bronowski, David R.; Kuthakun, Souvanny James

    The present study results are focused on laboratory testing of surrogate waste materials. The surrogate wastes correspond to a conservative estimate of degraded Waste Isolation Pilot Plant (WIPP) containers and TRU waste materials at the end of the 10,000 year regulatory period. Testing consists of hydrostatic, triaxial, and uniaxial strain tests performed on surrogate waste recipes that were previously developed by Hansen et al. (1997). These recipes can be divided into materials that simulate 50% and 100% degraded waste by weight. The percent degradation indicates the anticipated amount of iron corrosion, as well as the decomposition of cellulosics, plastics, andmore » rubbers (CPR). Axial, lateral, and volumetric strain and axial, lateral, and pore stress measurements were made. Two unique testing techniques were developed during the course of the experimental program. The first involves the use of dilatometry to measure sample volumetric strain under a hydrostatic condition. Bulk moduli of the samples measured using this technique were consistent with those measured using more conventional methods. The second technique involved performing triaxial tests under lateral strain control. By limiting the lateral strain to zero by controlling the applied confining pressure while loading the specimen axially in compression, one can maintain a right-circular cylindrical geometry even under large deformations. This technique is preferred over standard triaxial testing methods which result in inhomogeneous deformation or (3z(Bbarreling(3y. (BManifestations of the inhomogeneous deformation included non-uniform stress states, as well as unrealistic Poissons ratios (> 0.5) or those that vary significantly along the length of the specimen. Zero lateral strain controlled tests yield a more uniform stress state, and admissible and uniform values of Poissons ratio.« less

  6. Light-weight plastination.

    PubMed

    Steinke, Hanno; Rabi, Suganthy; Saito, Toshiyuki; Sawutti, Alimjan; Miyaki, Takayoshi; Itoh, Masahiro; Spanel-Borowski, Katharina

    2008-11-20

    Plastination is an excellent technique which helps to keep the anatomical specimens in a dry, odourless state. Since the invention of plastination technique by von Hagens, research has been done to improve the quality of plastinated specimens. In this paper, we have described a method of producing light-weight plastinated specimens using xylene along with silicone and in the final step, substitute xylene with air. The finished plastinated specimens were light-weight, dry, odourless and robust. This method requires less use of resin thus making the plastination technique more cost-effective. The light-weight specimens are easy to carry and can easily be used for teaching.

  7. A small punch test technique for characterizing the elastic modulus and fracture behavior of PMMA bone cement used in total joint replacement.

    PubMed

    Giddings, V L; Kurtz, S M; Jewett, C W; Foulds, J R; Edidin, A A

    2001-07-01

    Polymethylmethacrylate (PMMA) bone cement is used in total joint replacements to anchor implants to the underlying bone. Establishing and maintaining the integrity of bone cement is thus of critical importance to the long-term outcome of joint replacement surgery. The goal of the present study was to evaluate the suitability of a novel testing technique, the small punch or miniaturized disk bend test, to characterize the elastic modulus and fracture behavior of PMMA. We investigated the hypothesis that the crack initiation behavior of PMMA during the small punch test was sensitive to the test temperature. Miniature disk-shaped specimens, 0.5 mm thick and 6.4 mm in diameter, were prepared from PMMA and Simplex-P bone cement according to manufacturers' instructions. Testing was conducted at ambient and body temperatures, and the effect of test temperature on the elastic modulus and fracture behavior was statistically evaluated using analysis of variance. For both PMMA materials, the test temperature had a significant effect on elastic modulus and crack initiation behavior. At body temperature, the specimens exhibited "ductile" crack initiation, whereas at room temperature "brittle" crack initiation was observed. The small punch test was found to be a sensitive and repeatable test method for evaluating the mechanical behavior of PMMA. In light of the results of this study, future small punch testing should be conducted at body temperature.

  8. Adhesive performance of a multi-mode adhesive system: 1-year in vitro study.

    PubMed

    Marchesi, Giulio; Frassetto, Andrea; Mazzoni, Annalisa; Apolonio, Fabianni; Diolosà, Marina; Cadenaro, Milena; Di Lenarda, Roberto; Pashley, David H; Tay, Franklin; Breschi, Lorenzo

    2014-05-01

    The aim of this study was to investigate the adhesive stability over time of a multi-mode one-step adhesive applied using different bonding techniques on human coronal dentine. The hypotheses tested were that microtensile bond strength (μTBS), interfacial nanoleakage expression and matrix metalloproteinases (MMPs) activation are not affected by the adhesive application mode (following the use of self-etch technique or with the etch-and-rinse technique on dry or wet dentine) or by ageing for 24h, 6 months and 1year in artificial saliva. Human molars were cut to expose middle/deep dentine and assigned to one of the following bonding systems (N=15): (1) Scotchbond Universal (3M ESPE) self-etch mode, (2) Scotchbond Universal etch-and-rinse technique on wet dentine, (3) Scotchbond Universal etch-and-rinse technique on dry dentine, and (4) Prime&Bond NT (Dentsply De Trey) etch-and-rinse technique on wet dentine (control). Specimens were processed for μTBS test in accordance with the non-trimming technique and stressed to failure after 24h, 6 months or 1 year. Additional specimens were processed and examined to assay interfacial nanoleakage and MMP expression. At baseline, no differences between groups were found. After 1 year of storage, Scotchbond Universal applied in the self-etch mode and Prime&Bond NT showed higher μTBS compared to the other groups. The lowest nanoleakage expression was found for Scotchbond Universal applied in the self-etch mode, both at baseline and after storage. MMPs activation was found after application of each tested adhesive. The results of this study support the use of the self-etch approach for bonding the tested multi-mode adhesive system to dentine due to improved stability over time. Improved bonding effectiveness of the tested universal adhesive system on dentine may be obtained if the adhesive is applied with the self-etch approach. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Fatigue life prediction of bonded primary joints

    NASA Technical Reports Server (NTRS)

    Knauss, J. F.

    1979-01-01

    The validation of a proposed fatigue life prediction methodology was sought through the use of aluminum butt and scarf joint and graphite/epoxy butt joint specimens in a constant amplitude fatigue environment. The structural properties of the HYSOL 9313 adhesive system were obtained by mechanical test of molded heat adhesive specimens. Aluminum contoured double cantilever beam specimens were used to generate crack velocity versus stress intensity factor data. The specific objectives were: (1) to ascertain the feasibility of predicting fatigue failure of an adhesive in a primary bonded composite structure by incorporating linear elastic crack growth behavior; and (2) to ascertain if acoustic emission and/or compliance measurement techniques can be used to detect flaws.

  10. Study of residual stresses in CT test specimens welded by electron beam

    NASA Astrophysics Data System (ADS)

    Papushkin, I. V.; Kaisheva, D.; Bokuchava, G. D.; Angelov, V.; Petrov, P.

    2018-03-01

    The paper reports result of residual stress distribution studies in CT specimens reconstituted by electron beam welding (EBW). The main aim of the study is evaluation of the applicability of the welding technique for CT specimens’ reconstitution. Thus, the temperature distribution during electron beam welding of a CT specimen was calculated using Green’s functions and the residual stress distribution was determined experimentally using neutron diffraction. Time-of-flight neutron diffraction experiments were performed on a Fourier stress diffractometer at the IBR-2 fast pulsed reactor in FLNP JINR (Dubna, Russia). The neutron diffraction data estimates yielded a maximal stress level of ±180 MPa in the welded joint.

  11. Fatigue lifetime prediction of a reduced-diameter dental implant system: Numerical and experimental study.

    PubMed

    Duan, Yuanyuan; Gonzalez, Jorge A; Kulkarni, Pratim A; Nagy, William W; Griggs, Jason A

    2018-06-16

    To validate the fatigue lifetime of a reduced-diameter dental implant system predicted by three-dimensional finite element analysis (FEA) by testing physical implant specimens using an accelerated lifetime testing (ALT) strategy with the apparatus specified by ISO 14801. A commercially-available reduced-diameter titanium dental implant system (Straumann Standard Plus NN) was digitized using a micro-CT scanner. Axial slices were processed using an interactive medical image processing software (Mimics) to create 3D models. FEA analysis was performed in ABAQUS, and fatigue lifetime was predicted using fe-safe ® software. The same implant specimens (n=15) were tested at a frequency of 2Hz on load frames using apparatus specified by ISO 14801 and ALT. Multiple step-stress load profiles with various aggressiveness were used to improve testing efficiency. Fatigue lifetime statistics of physical specimens were estimated in a reliability analysis software (ALTA PRO). Fractured specimens were examined using SEM with fractographic technique to determine the failure mode. FEA predicted lifetime was within the 95% confidence interval of lifetime estimated by experimental results, which suggested that FEA prediction was accurate for this implant system. The highest probability of failure was located at the root of the implant body screw thread adjacent to the simulated bone level, which also agreed with the failure origin in physical specimens. Fatigue lifetime predictions based on finite element modeling could yield similar results in lieu of physical testing, allowing the use of virtual testing in the early stages of future research projects on implant fatigue. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.

  12. Presence of Cross-Reactions with Other Viral Encephalitides in the Indirect Fluorescent-Antibody Test for Diagnosis of Rabies

    PubMed Central

    Appler, Kim A.; Wong, Susan J.

    2013-01-01

    The antemortem diagnosis of rabies in humans employs techniques that require accuracy, speed, and sensitivity. A combination of histochemical analysis, in vitro virus isolation, immunological methods, and molecular amplification procedures are utilized in efforts to diagnose the disease. Modern medicine now offers potentially life-saving treatment for a disease that was considered invariably fatal once clinical signs develop. However, medical intervention efforts require a rapid and accurate diagnosis as early in the course of clinical disease as possible. Indirect fluorescent-antibody (IFA) testing on cerebrospinal fluid and serum specimens provides rapid results, but the specificity of the assay has not been well studied. Because false-positive IFA results could significantly affect patient treatment and outcomes, it is critical to understand the specificity of this assay. In this study, IFA testing was performed on 135 cerebrospinal fluid and serum specimens taken from patients with viral encephalitis or a presumed viral infection involving an agent other than rabies virus. Results indicate that false-positive results can occur in interpreting the rabies IFA test. Staining patterns morphologically similar to antirabies staining were observed in 7 of the 135 cerebrospinal fluid specimens examined. In addition, a majority of the cerebrospinal fluid specimens tested from patients with encephalitis presented immunoglobulin that bound to antigens present in the cell culture substrate. Of marked concern was the frequent presence of cross-reactive antibodies in encephalitis cases associated with West Nile and Powassan flaviviruses. Because IFA testing for rabies on human specimens may result in false-positive results, it should not be used as the sole basis for initiating antirabies treatment. PMID:24088851

  13. Presence of cross-reactions with other viral encephalitides in the indirect fluorescent-antibody test for diagnosis of rabies.

    PubMed

    Rudd, Robert J; Appler, Kim A; Wong, Susan J

    2013-12-01

    The antemortem diagnosis of rabies in humans employs techniques that require accuracy, speed, and sensitivity. A combination of histochemical analysis, in vitro virus isolation, immunological methods, and molecular amplification procedures are utilized in efforts to diagnose the disease. Modern medicine now offers potentially life-saving treatment for a disease that was considered invariably fatal once clinical signs develop. However, medical intervention efforts require a rapid and accurate diagnosis as early in the course of clinical disease as possible. Indirect fluorescent-antibody (IFA) testing on cerebrospinal fluid and serum specimens provides rapid results, but the specificity of the assay has not been well studied. Because false-positive IFA results could significantly affect patient treatment and outcomes, it is critical to understand the specificity of this assay. In this study, IFA testing was performed on 135 cerebrospinal fluid and serum specimens taken from patients with viral encephalitis or a presumed viral infection involving an agent other than rabies virus. Results indicate that false-positive results can occur in interpreting the rabies IFA test. Staining patterns morphologically similar to antirabies staining were observed in 7 of the 135 cerebrospinal fluid specimens examined. In addition, a majority of the cerebrospinal fluid specimens tested from patients with encephalitis presented immunoglobulin that bound to antigens present in the cell culture substrate. Of marked concern was the frequent presence of cross-reactive antibodies in encephalitis cases associated with West Nile and Powassan flaviviruses. Because IFA testing for rabies on human specimens may result in false-positive results, it should not be used as the sole basis for initiating antirabies treatment.

  14. Comparative Stress Corrosion Cracking and General Corrosion Resistance of Annealed and Hardened 440 C Stainless Steel - New Techniques in Stress Corrosion Testing

    NASA Technical Reports Server (NTRS)

    Mendreck, M. J.; Hurless, B. E.; Torres, P. D.; Danford, M. D.

    1998-01-01

    The corrosion and stress corrosion cracking (SCC) characteristics of annealed and hardened 440C stainless steel were evaluated in high humidity and 3.5-percent NaCl solution. Corrosion testing consisted of an evaluation of flat plates, with and without grease, in high humidity, as well as electrochemical testing in 3.5-percent NaCl. Stress corrosion testing consisted of conventional, constant strain, smooth bar testing in high humidity in addition to two relatively new techniques under evaluation at MSFC. These techniques involve either incremental or constant rate increases in the load applied to a precracked SE(B) specimen, monitoring the crack-opening-displacement response for indications of crack growth. The electrochemical corrosion testing demonstrated an order of magnitude greater general corrosion rate in the annealed 440C. All techniques for stress corrosion testing showed substantially better SCC resistance in the annealed material. The efficacy of the new techniques for stress corrosion testing was demonstrated both by the savings in time and the ability to better quantify SCC data.

  15. The effect of collagen crosslinking on the biphasic poroviscoelastic cartilage properties determined from a semi-automated microindentation protocol for stress relaxation.

    PubMed

    McGann, Megan E; Bonitsky, Craig M; Ovaert, Timothy C; Wagner, Diane R

    2014-06-01

    Given the important role of the collagenous structure in cartilage mechanics, there is considerable interest in the relationship between collagen crosslinking and the mechanical behavior of the cartilage matrix. While crosslink-induced alterations to the elastic modulus of cartilage have been described, changes to time-dependent behavior have not yet been determined. The objective of the study was to quantify changes to cartilage material properties, including viscoelastic coefficients, with crosslinking via indentation. To accomplish this, a semi-autonomous microindentation stress relaxation protocol was first developed, validated and then applied to cartilage specimens before and after crosslinking. The change in mechanical properties with crosslinking was analyzed both in the unloading portions of the test via the Oliver-Pharr method and in the holding portion with an inverse iterative finite element model that represented cartilage as a biphasic poroviscoelastic material. Although both techniques suggested a similar increase in equilibrium modulus in the crosslinked specimens as compared to the controls, distinct differences in the control specimens were apparent, suggesting that the two different techniques may be capturing different aspects of the material behavior. No differences in time-dependent properties were observed between the crosslinked and the control specimens. These results give further insight into the effects of crosslinking in cartilage mechanical behavior. Additionally, the microindentation stress relaxation protocol may enable increased automation for high-throughput testing. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Prevention of longitudinal crack propagation around a femoral prosthesis: a study of cerclage wire fixation.

    PubMed

    Difazio, F A; Incavo, S J; Howe, J D

    1993-09-01

    This study examined the effect of single versus triple-wrap cerclage fixation techniques in preventing propagation of a longitudinal fracture around a cementless femoral prosthesis. A proximal filling femoral component was implanted in 14 matched pairs of fresh-frozen bovine femora, following placement of a 45-mm longitudinal crack in the anteromedial cortical wall of the proximal femur. In one group of seven pairs, a single cerclage wire was applied to one specimen of each pair. A triple-wrap of a single cerclage wire was similarly placed in one specimen of each of the other seven pairs. All specimens were axially loaded on a materials testing system machine and the force required to propagate the fracture of the proximal femur was recorded. A triple-wrap cerclage technique required a significant increase in the force to propagate a proximal femur fracture around a non-cemented prosthesis when compared to a single cerclage wire. Copyright © 1993. Published by Elsevier Ltd.

  17. Effect of an internal coating technique on tensile bond strengths of resin cements to zirconia ceramics.

    PubMed

    Kitayama, Shuzo; Nikaido, Toru; Maruoka, Rena; Zhu, Lei; Ikeda, Masaomi; Watanabe, Akihiko; Foxton, Richard M; Miura, Hiroyuki; Tagami, Junji

    2009-07-01

    This study was conducted to enhance the tensile bond strengths of resin cements to zirconia ceramics. Fifty-six zirconia ceramic specimens (Cercon Base) and twenty-eight silica-based ceramic specimens (GN-1, GN-1 Ceramic Block) were air-abraded using alumina. Thereafter, the zirconia ceramic specimens were divided into two subgroups of 28 each according to the surface pretreatment; no pretreatment (Zr); and the internal coating technique (INT). For INT, the surface of zirconia was coated by fusing silica-based ceramics (Cercon Ceram Kiss). Ceramic surfaces were conditioned with/without a silane coupling agent followed by bonding with one of two resin cements; Panavia F 2.0 (PF) and Superbond C&B (SB). After 24 hours storage in water, the tensile bond strengths were tested (n=7). For both PF and SB, silanization significantly improved the bond strength to GN-1 and INT (p<0.05). The INT coating followed by silanizaton demonstrated enhancement of bonding to zirconia ceramics.

  18. Evaluation of lateral flow devices for identification of infected poultry by testing swab and feather specimens during H5N1 highly pathogenic avian influenza outbreaks in Vietnam

    PubMed Central

    Slomka, Marek J.; To, Thanh L.; Tong, Hien H.; Coward, Vivien J.; Mawhinney, Ian C.; Banks, Jill; Brown, Ian H.

    2011-01-01

    Please cite this paper as: Slomka et al. (2012) Evaluation of lateral flow devices for identification of infected poultry by testing swab and feather specimens during H5N1 highly pathogenic avian influenza outbreaks in Vietnam. Influenza and Other Respiratory Viruses 6(5), 318–327. Background  Evaluation of two commercial lateral flow devices (LFDs) for avian influenza (AI) detection in H5N1 highly pathogenic AI infected poultry in Vietnam. Objectives  Determine sensitivity and specificity of the LFDs relative to a validated highly sensitive H5 RRT PCR. Methods  Swabs (cloacal and tracheal) and feathers were collected from 46 chickens and 48 ducks (282 clinical specimens) and tested by both LFDs and H5 RRT PCR. A subset of 59 chicken and 34 duck specimens was also tested by virus isolation (VI), the ‘gold standard’. Results  Twenty‐six chickens and 15 ducks were shown to be infected by at least one RRT PCR positive clinical specimen per bird. Bird‐level sensitivity for the Anigen LFD was 84·6% for chickens and 53·3% for ducks, and for the Quickvue LFD 65·4% for chickens and 33·3% for ducks. Comparison of the three clinical specimens revealed that chicken feathers were the most sensitive with 84% and 56% sensitivities for Anigen and Quickvue respectively. All 21 RRT PCR positive swabs from ducks were negative by both LFDs. However, duck feather testing gave sensitivities of 53·3% and 33·3% for Anigen and Quickvue respectively. Specificity was 100% for both LFDs in all investigations. Conclusions  Although LFDs were less sensitive than AI RRT PCR and VI, high titre viral shedding in H5N1 highly pathogenic avian influenza (HPAI) infected and diseased chickens is sufficient for a proportion of birds to be identified as AI infected by LFDs. Feathers were the optimal specimen for LFD testing in such diseased HPAI scenarios, particularly for ducks where swab testing by LFDs failed to identify any infected birds. However, specimens should be forwarded to the laboratory for confirmation by more sensitive diagnostic techniques. PMID:22151025

  19. In situ X-ray monitoring of damage accumulation in SiC/RBSN tensile specimens

    NASA Technical Reports Server (NTRS)

    Baaklini, George Y.; Bhatt, Ramkrishna T.

    1991-01-01

    The room-temperature tensile testing of silicon carbide fiber reinforced reaction-bonded silicon nitride (SiC/RBSN) composite specimens was monitored by using in-situ X-ray film radiography. Radiographic evaluation before, during, and after loading provided data on the effect of preexisting volume flaws (high density impurities, and local density variations) on the fracture behavior of composites. Results from (O)1, (O)3, (O)5, and (O)8 composite specimens showed that X-ray film radiography can monitor damage accumulations during tensile loading. Matrix cracking, fiber-matrix debonding, and fiber pullout were imaged throughout the tensile loading history of the specimens. Further, in-situ film radiography was found to be a helpful and practical technique for estimating interfacial shear strength between the SiC fiber and the RBSN matrix by the matrix crack spacing method. It is concluded that pretest, in-situ, and post-test radiography can provide for a greater understanding of ceramic matrix composite mechanical behavior, a verification of related experimental procedures, and a validation and development of related analytical models.

  20. In-situ x-ray monitoring of damage accumulation in SiC/RBSN tensile specimens

    NASA Technical Reports Server (NTRS)

    Baaklini, George Y.; Bhatt, Ramakrishna T.

    1991-01-01

    The room-temperature tensile testing of silicon carbide fiber reinforced reaction-bonded silicon nitride (SiC/RBSN) composite specimens was monitored by using in-situ x ray film radiography. Radiographic evaluation before, during, and after loading provided data on the effect of preexisting volume flaws (high density impurities, and local density variations) on the fracture behavior of composites. Results from (0)1, (0)3, (0)5, and (0)8 composite specimens, showed that x ray film radiography can monitor damage accumulations during tensile loading. Matrix cracking, fiber-matrix debonding, and fiber pullout were imaged throughout the tensile loading history of the specimens. Further, in-situ film radiography was found to be a helpful and practical technique for estimating interfacial shear strength between the SiC fiber and the RBSN matrix by the matrix crack spacing method. It is concluded that pretest, in-situ, and post-test radiography can provide for a greater understanding of ceramic matrix composite mechanical behavior, a verification of related experimental procedures, and a validation and development of related analytical models.

  1. Influence of additional coupling agent on the mechanical properties of polyester–agave cantala roxb based composites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ubaidillah, E-mail: ubaidillah@uns.ac.id; Malaysia-Japan International Institute of Technology, Universiti Teknologi Malaysia, Jalan Sultan Yahya Petra, Kuala Lumpur; Raharjo, Wijang W.

    The mechanical and morphological properties of the unsaturated polyester resins (UPRs)-agave cantala roxb based composite are investigated in this paper. The cantala fiber woven in 3D angle interlock was utilized as the composite reinforcement. Surface grafting of the cantala fiber through chemical treatment was performed by introducing silane coupling agent to improving the compatibility with the polymer matrix. The fabrication of the composite specimens was conducted using vacuum bagging technique. The effect of additional coupling agent to the morphological appearance of surface fracture was observed using scanning electron microscopy. Meanwhile, the influence of additional silane to the mechanical properties wasmore » examined using tensile, bending and impact test. The photograph of surface fracture on the treated specimens showed the residual matrix left on the fibers in which the phenomenon was not found in the untreated specimens. Based on mechanical tests, the treated specimens were successfully increased their mechanical properties by 55%, 9.67%, and 92.4% for tensile strength, flexural strength, and impact strength, respectively, at 1.5% silane coupling agent.« less

  2. Numerical simulations of wave propagation in long bars with application to Kolsky bar testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Corona, Edmundo

    2014-11-01

    Material testing using the Kolsky bar, or split Hopkinson bar, technique has proven instrumental to conduct measurements of material behavior at strain rates in the order of 10 3 s -1. Test design and data reduction, however, remain empirical endeavors based on the experimentalist's experience. Issues such as wave propagation across discontinuities, the effect of the deformation of the bar surfaces in contact with the specimen, the effect of geometric features in tensile specimens (dog-bone shape), wave dispersion in the bars and other particulars are generally treated using simplified models. The work presented here was conducted in Q3 and Q4more » of FY14. The objective was to demonstrate the feasibility of numerical simulations of Kolsky bar tests, which was done successfully.« less

  3. Influence of Cr and W alloying on the fiber-matrix interfacial shear strength in cast and directionally solidified sapphire NiAl composites

    NASA Technical Reports Server (NTRS)

    Asthana, R.; Tiwari, R.; Tewari, S. N.

    1995-01-01

    Sapphire-reinforced NiAl matrix composites with chromium or tungsten as alloying additions were synthesized using casting and zone directional solidification (DS) techniques and characterized by a fiber pushout test as well as by microhardness measurements. The sapphire-NiAl(Cr) specimens exhibited an interlayer of Cr rich eutectic at the fiber-matrix interface and a higher interfacial shear strength compared to unalloyed sapphire-NiAl specimens processed under identical conditions. In contrast, the sapphire-NiAl(W) specimens did not show interfacial excess of tungsten rich phases, although the interfacial shear strength was high and comparable to that of sapphire-NiAl(Cr). The postdebond sliding stress was higher in sapphire-NiAl(Cr) than in sapphire-NiAl(W) due to interface enrichment with chromium particles. The matrix microhardness progressively decreased with increasing distance from the interface in both DS NiAl and NiAl(Cr) specimens. The study highlights the potential of casting and DS techniques to improve the toughness and strength of NiAl by designing dual-phase microstructures in NiAl alloys reinforced with sapphire fibers.

  4. Influence of Ply Waviness on Fatigue Life of Tapered Composite Flexbeam Laminates

    NASA Technical Reports Server (NTRS)

    Murri, Gretchen B.

    1999-01-01

    Nonlinear tapered flexbeam laminates, with significant ply waviness, were cut from a full-size composite rotor hub flexbeam. The specimens were tested under combined axial tension and cyclic bending loads. All of the specimens had wavy plies through the center and near the surfaces (termed marcelled areas), although for some of the specimens the surface marcels were very obvious, and for others they were much smaller. The specimens failed by first developing cracks through the marcels at the surfaces, and then delaminations grew from those cracks, in both directions. Delamination failure occurred in these specimens at significantly shorter fatigue lives than similar specimens without waviness, tested in ref. 2. A 2D finite element model was developed which closely approximated the flexbeam geometry, boundary conditions, and loading. In addition, the FE model duplicated the waviness observed in one of the test specimens. The model was analyzed using a geometrically nonlinear FE code. Modifications were made to the original model to reduce the amplitude of the marcels near the surfaces. The analysis was repeated for each modification. Comparisons of the interlaminar normal stresses, sigma(sub n), in the various models showed that under combined axial-tension and cyclic-bending loading, for marcels of the same aspect ratio, sigma(sub n) stresses increased as the distance along the taper, from thick to thin end, increased. For marcels of the same aspect ratio and at the same X-location along the taper, sigma(sub n) stresses decreased as the distance from the surface into the flexbeam interior increased. A technique was presented for determining the smallest acceptable marcel aspect ratio at various locations in the flexbeam.

  5. 21 CFR 864.1860 - Immunohistochemistry reagents and kits.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Immunohistochemistry reagents and kits. (a) Identification. Immunohistochemistry test systems (IHC's) are in vitro... performance claims, which may be packaged with ancillary reagents in kits. Their intended use is to identify, by immunological techniques, antigens in tissues or cytologic specimens. Similar devices intended for...

  6. 21 CFR 864.1860 - Immunohistochemistry reagents and kits.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Immunohistochemistry reagents and kits. (a) Identification. Immunohistochemistry test systems (IHC's) are in vitro... performance claims, which may be packaged with ancillary reagents in kits. Their intended use is to identify, by immunological techniques, antigens in tissues or cytologic specimens. Similar devices intended for...

  7. Fracture Resistance of Retreated Roots Using Different Retreatment Systems

    PubMed Central

    Er, Kursat; Tasdemir, Tamer; Siso, Seyda Herguner; Celik, Davut; Cora, Sabri

    2011-01-01

    Objectives: This study was designed to evaluate the fracture resistance of retreated roots using different rotary retreatment systems. Methods: Forty eight freshly extracted human canine teeth with single straight root canals were instrumented sequentially increasing from size 30 to a size 55 using K-files whit a stepback technique. The teeth were randomly divided into three experimental and one control groups of 12 specimens each. The root canals were filled using cold lateral compaction of gutta-percha and AH Plus (Dentsply Detrey, Konstanz, Germany) sealer in experimental groups. Removal of gutta-percha was performed with the following devices and techniques: ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland), R-Endo (Micro-Mega, Besançon, France), and Mtwo (Sweden & Martina, Padova, Italy) rotary retreatment systems. Control group specimens were only instrumented, not filled or retreated. The specimens were then mounted in copper rings, were filled with a self-curing polymethylmethacrylate resin, and the force required to cause vertical root fracture was measured using a universal testing device. The force of fracture of the roots was recorded and the results in the various groups were compared. Statistical analysis was accomplished by one-way ANOVA and a post hoc Tukey tests. Results: There were statistically significant differences between the control and experimental groups (P<.05). However, there were no significant differences among the experimental groups. Conclusions: Based on the results, all rotary retreatment techniques used in this in vitro study produced similar root weakness. PMID:21912497

  8. Effect of Instrumentation Techniques, Irrigant Solutions and Artificial accelerated Aging on Fiberglass Post Bond Strength to Intraradicular Dentin.

    PubMed

    Santana, Fernanda Ribeiro; Soares, Carlos José; Silva, Júlio Almeida; Alencar, Ana Helena Gonçalves; Renovato, Sara Rodrigues; Lopes, Lawrence Gonzaga; Estrela, Carlos

    2015-07-01

    To evaluate the effect of instrumentation techniques, irrigant solutions and specimen aging on fiberglass posts bond strength to intraradicular dentine. A total of 120 bovine teeth were prepared and randomized into control and experimental groups resulting from three study factors (instrumentation techniques, irrigant solutions, specimen aging). Posts were cemented with RelyX U100. Samples were submitted to push-out test and failure mode was evaluated under a confocal microscope. In specimens submitted to water artificial aging, nickel-titanium rotary instruments group presented higher bond strength values in apical third irrigated with NaOCl or chlorhexi-dine. Irrigation with NaOCl resulted in higher bond strength than ozonated water. Artificial aging resulted in significant bond strength increase. Adhesive cement-dentin failure was prevalent in all the groups. Root canal preparation with NiTi instruments associated with NaOCl irrigation and ethylenediaminetetra acetic acid (EDTA) increased bond strength of fiberglass posts cemented with self-adhesive resin cement to intraradicular dentine. Water artificial aging significantly increased post-Clinical significance: The understanding of factors that may influence the optimal bond between post-cement and cement-dentin are essential to the success of endodontically treated tooth restoration.

  9. Effects of various polishing techniques and thermal cycling on the surface roughness and color change of polymer-based CAD/CAM materials.

    PubMed

    Acar, Burcu; Egilmez, Ferhan

    2018-04-01

    To investigate and compare the effects of several polishing systems and thermal cycling on the surface roughness and color change of various polymer-based CAD/CAM materials. Bar-shaped specimens (GC CeraSmart, CS; Lava Ultimate, LU and Vita Enamic, VE) were prepared. All specimens were polished with SiC papers. The specimens in Group A served as control and no additional surface polishing was applied. Final polishing was performed using diamond polishing paste (Diapolisher Paste) in Group B. In Group C, aluminum oxide abrasive discs (Sof-Lex XT Pop on) were used. Group D was polished with diamond impregnated spiral polishing system (EVE Diacomp Plus Twist). In Group E, polishing was done with rubber-based silicon abrasives (Polydentia). Thereafter, the specimens were submitted to thermal cycling. The surface roughness and color measurements were performed. Kruskal-Wallis and the Mann-Whitney U tests were applied for the evaluation of ΔE₀₀ data. Ra data were evaluated using three-way ANOVA. Pearson's correlation between Ra and ΔE₀₀ was further investigated. Neither the CAD/CAM materials nor thermal cycling affected the Ra data (P> 0.05). In contrast, significant difference was found among the polishing methods (P< 0.001). On the other hand, VE showed the highest color change whereas LU showed the lowest (P< 0.05). Additionally, the specimens in Group D exhibited significantly higher color change than other tested groups (P< 0.05). A moderate positive correlation was seen between Ra and ΔE₀₀ data of LU (rho = 0.390, P= 0.01). The diamond impregnated two-stage polishing procedure may not be an appropriate method for the tested CAD/CAM materials, as it resulted in the highest color change. On the other hand, all tested materials exhibited visually perceptible, but clinically acceptable color changes following the different polishing techniques. Additionally, diamond paste polishing could be a clinically acceptable procedure in terms of surface roughness. Copyright©American Journal of Dentistry.

  10. Numerical and analytical modeling of the end-loaded split (ELS) test specimens made of multi-directional coupled composite laminates

    NASA Astrophysics Data System (ADS)

    Samborski, Sylwester; Valvo, Paolo S.

    2018-01-01

    The paper deals with the numerical and analytical modelling of the end-loaded split test for multi-directional laminates affected by the typical elastic couplings. Numerical analysis of three-dimensional finite element models was performed with the Abaqus software exploiting the virtual crack closure technique (VCCT). The results show possible asymmetries in the widthwise deflections of the specimen, as well as in the strain energy release rate (SERR) distributions along the delamination front. Analytical modelling based on a beam-theory approach was also conducted in simpler cases, where only bending-extension coupling is present, but no out-of-plane effects. The analytical results matched the numerical ones, thus demonstrating that the analytical models are feasible for test design and experimental data reduction.

  11. The effect of different final irrigant activation techniques on the bond strength of an epoxy resin-based endodontic sealer: a preliminary study.

    PubMed

    Topçuoğlu, Hüseyin Sinan; Tuncay, Öznur; Demirbuga, Sezer; Dinçer, Asiye Nur; Arslan, Hakan

    2014-06-01

    The aim of this study was to evaluate whether or not different final irrigation activation techniques affect the bond strength of an epoxy resin-based endodontic sealer (AH Plus; Dentsply DeTrey, Konstanz, Germany) to the root canal walls of different root thirds. Eighty single-rooted human mandibular premolars were prepared by using the ProTaper system (Dentsply Maillefer, Ballaigues, Switzerland) to size F4, and a final irrigation regimen using 3% sodium hypochlorite and 17% EDTA was performed. The specimens were randomly divided into 4 groups (n = 20) according to the final irrigation activation technique used as follows: no activation (control), manual dynamic activation (MDA), CanalBrush (Coltene Whaledent, Altststten, Switzerland) activation, and ultrasonic activation. Five specimens from each group were prepared for scanning electron microscopic observation to assess the smear layer removal after the final irrigation procedures. All remaining roots were then obturated with gutta-percha and AH Plus sealer. A push-out test was used to measure the bond strength between the root canal dentin and AH Plus sealer. The data obtained from the push-out test were analyzed using 2-way analysis of variance and Tukey post hoc tests. The bond strength values mostly decreased in the coronoapical direction (P < .001). In the coronal and middle thirds, ultrasonic activiation showed a higher bond strength than other groups (P < .05). In the apical third, MDA displayed the highest bond strength to root dentin (P < .05). The majority of specimens exhibited cohesive failures. The bond strength of AH Plus sealer to root canal dentin may improve with ultrasonic activation in the coronal and middle thirds and MDA in the apical third. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  12. Intact Imaging of Human Heart Structure Using X-ray Phase-Contrast Tomography.

    PubMed

    Kaneko, Yukihiro; Shinohara, Gen; Hoshino, Masato; Morishita, Hiroyuki; Morita, Kiyozo; Oshima, Yoshihiro; Takahashi, Masashi; Yagi, Naoto; Okita, Yutaka; Tsukube, Takuro

    2017-02-01

    Structural examination of human heart specimens at the microscopic level is a prerequisite for understanding congenital heart diseases. It is desirable not to destroy or alter the properties of such specimens because of their scarcity. However, many of the currently available imaging techniques either destroy the specimen through sectioning or alter the chemical and mechanical properties of the specimen through staining and contrast agent injection. As a result, subsequent studies may not be possible. X-ray phase-contrast tomography is an imaging modality for biological soft tissues that does not destroy or alter the properties of the specimen. The feasibility of X-ray phase-contrast tomography for the structural examination of heart specimens was tested using infantile and fetal heart specimens without congenital diseases. X-ray phase-contrast tomography was carried out at the SPring-8 synchrotron radiation facility using the Talbot grating interferometer at the bending magnet beamline BL20B2 to visualize the structure of five non-pretreated whole heart specimens obtained by autopsy. High-resolution, three-dimensional images were obtained for all specimens. The images clearly showed the myocardial structure, coronary vessels, and conduction bundle. X-ray phase-contrast tomography allows high-resolution, three-dimensional imaging of human heart specimens. Intact imaging using X-ray phase-contrast tomography can contribute to further structural investigation of heart specimens with congenital heart diseases.

  13. Shockless spalling damage of alumina ceramic

    NASA Astrophysics Data System (ADS)

    Erzar, B.; Buzaud, E.

    2012-05-01

    Ceramic materials are commonly used to build multi-layer armour. However reliable test data is needed to identify correctly models and to be able to perform accurate numerical simulation of the dynamic response of armour systems. In this work, isentropic loading waves have been applied to alumina samples to induce spalling damage. The technique employed allows assessing carefully the strain-rate at failure and the dynamic strength. Moreover, specimens have been recovered and analysed using SEM. In a damaged but unbroken specimen, interactions between cracks has been highlighted illustrating the fragmentation process.

  14. Construct stability of an instrumented 2-level cervical corpectomy model following fatigue testing: biomechanical comparison of circumferential antero-posterior instrumentation versus a novel anterior-only transpedicular screw-plate fixation technique.

    PubMed

    Koller, Heiko; Schmoelz, Werner; Zenner, Juliane; Auffarth, Alexander; Resch, Herbert; Hitzl, Wolfgang; Malekzadeh, Davud; Ernstbrunner, Lukas; Blocher, Martina; Mayer, Michael

    2015-12-01

    A high rate of complications in multilevel cervical surgery with corpectomies and anterior-only screw-and-plate stabilization is reported. A 360°-instrumentation improves construct stiffness and fusion rates, but adds the morbidity of a second approach. A novel ATS-technique (technique that used anterior transpedicular screw placement) was recently described, yet no study to date has analyzed its performance after fatigue loading. Accordingly, the authors performed an analysis of construct stiffness after fatigue testing of a cervical 2-level corpectomy model reconstructed using a novel anterior transpedicular screw-and-plate technique (ATS-group) in comparison to standard antero-posterior instrumentation (360°-group). Twelve fresh-frozen human cervical spines were mounted on a spine motion tester to analyze restriction of ROM under loading (1.5 Nm) in flexion-extension (FE), axial rotation (AR), and lateral bending (LB). Testing was performed in the intact state, and after instrumentation of a 2-level corpectomy C4 + C5 using a cage and the constructs of ATS- and 360°-group, after 1,000 cycles, and after 2,000 cycles of fatigue testing. In the ATS-group (n = 6), instrumentation was achieved using a customized C3-C6 ATS-plate system. In the 360°-group (n = 6), instrumentation consisted of a standard anterior screw-and-plate system with a posterior instrumentation using C3-C6 lateral mass screws. Motion data were assessed as degrees and further processed as normalized values after standardization to the intact ROM state. Specimen age and BMD were not significantly different between the ATS- and 360°-groups. After instrumentation and 2,000 cycles of testing, no specimen exhibited a ROM greater than in the intact state. No specimen exhibited catastrophic construct failure after 2,000 cycles. Construct stiffness in the 360°-group was significantly increased compared to the ATS-group for all loading conditions, except for FE-testing after instrumentation. After 2,000 cycles, restriction of ROM under loading in FE was 39.8 ± 30% in the ATS-group vs. 2.8 ± 2.3% in the 360°-group, in AR 60.4 ± 25.8 vs 15 ± 11%, and in LB 40 ± 23.4 vs 3.9 ± 1.2%. Differences were significant (p < 0.05). 360°-instrumentation resembles the biomechanical standard of reference for stabilization of 2-level corpectomies. An ATS-construct was also shown to confer high construct stiffness, significantly reducing the percentage ROM beyond that of an intact specimen after 2,000 cycles. This type of instrumentation might be a clinical valuable and biomechanically sound adjunct to multilevel anterior surgical procedures.

  15. Accelerated Determination of ASR Susceptibility during Concrete Prism Testing through Nonlinear Resonance Ultrasonic Spectroscopy : TechBrief

    DOT National Transportation Integrated Search

    2013-10-01

    The research has been conducted on laboratory-cast concrete prism specimens containing both fine and coarse aggregates obtained from different sources to provide a spectrum of reactivity for assessment through the developed NIRAS technique. The NIRAS...

  16. 21 CFR 809.10 - Labeling for in vitro diagnostic products.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... principles of the procedure. Explain concisely, with chemical reactions and techniques involved, if...) Instruments: (i) Use or function. (ii) Installation procedures and special requirements. (iii) Principles of... product testing prior to full commercial marketing (for example, for use on specimens derived from humans...

  17. Ageing under mechanical stress: first experiments for a silver based multilayer mirror

    NASA Astrophysics Data System (ADS)

    Lalo, Arnaud; Ravel, Guillaume; Ignat, Michel; Cousin, Bernard; Swain, Michael V.

    2017-11-01

    Improving materials and devices reliability is a major concern to the spatial industry. Results are reported for satellite mirrors-like specimens consisting in oxide-protected metal systems. Optical coatings were deposited by electron beam evaporation. Mechanical stress fields in multi-layered materials play an important role. The stress state can have far-reaching implications both in kinetics and thermodynamics. Therefore an integrated apparatus with four-point bending equipment was designed. The technique allowed us to exert stress into a film or a system of films on a substrate concurrently with thermal treatment. In order to achieve the first tests performed with the help of the apparatus, various preliminary characterizations were required. The article reports the preliminary micro-mechanical testing of the materials (ultra micro-indentation to evaluate the elastic modulus of the samples materials and wafer curvature technique to determine the specimen residual stress) and the first ageing experiment. Experimental evidence of accelerated ageing under stress is successfully reported.

  18. Umbilical Connect Techniques Improvement-Technology Study

    NASA Technical Reports Server (NTRS)

    Valkema, Donald C.

    1972-01-01

    The objective of this study was to develop concepts, specifications, designs, techniques, and procedures capable of significantly reducing the time required to connect and verify umbilicals for ground services to the space shuttle. The desired goal was to reduce the current time requirement of several shifts for the Saturn 5/Apollo to an elapsed time of less than one hour to connect and verify all of the space shuttle ground service umbilicals. The study was conducted in four phases: (1) literature and hardware examination, (2) concept development, (3) concept evaluation and tradeoff analysis, and (4) selected concept design. The final product of this study was a detail design of a rise-off disconnect panel prototype test specimen for a LO2/LH2 booster (or an external oxygen/hydrogen tank for an orbiter), a detail design of a swing-arm mounted preflight umbilical carrier prototype test specimen, and a part 1 specification for the umbilical connect and verification design for the vehicles as defined in the space shuttle program.

  19. Concrete Condition Assessment Using Impact-Echo Method and Extreme Learning Machines

    PubMed Central

    Zhang, Jing-Kui; Yan, Weizhong; Cui, De-Mi

    2016-01-01

    The impact-echo (IE) method is a popular non-destructive testing (NDT) technique widely used for measuring the thickness of plate-like structures and for detecting certain defects inside concrete elements or structures. However, the IE method is not effective for full condition assessment (i.e., defect detection, defect diagnosis, defect sizing and location), because the simple frequency spectrum analysis involved in the existing IE method is not sufficient to capture the IE signal patterns associated with different conditions. In this paper, we attempt to enhance the IE technique and enable it for full condition assessment of concrete elements by introducing advanced machine learning techniques for performing comprehensive analysis and pattern recognition of IE signals. Specifically, we use wavelet decomposition for extracting signatures or features out of the raw IE signals and apply extreme learning machine, one of the recently developed machine learning techniques, as classification models for full condition assessment. To validate the capabilities of the proposed method, we build a number of specimens with various types, sizes, and locations of defects and perform IE testing on these specimens in a lab environment. Based on analysis of the collected IE signals using the proposed machine learning based IE method, we demonstrate that the proposed method is effective in performing full condition assessment of concrete elements or structures. PMID:27023563

  20. An Interlaminar Tensile Strength Specimen

    NASA Technical Reports Server (NTRS)

    Martin, Roderick H.; Jackson, Wade C.

    1993-01-01

    This paper describes a technique to determine interlaminar tensile strength, sigma(sub 3c), of a fiber reinforced composite material using a curved beam. The specimen was a unidirectional curved beam, bent 90 deg, with straight arms. Attached to each arm was a hinged loading mechanism that was held by the grips of a tension testing machine. Geometry effects of the specimen, including the effects of loading arm length, inner radius, thickness, and width, were studied. The data sets fell into two categories: low strength corresponding to a macroscopic flaw related failure and high strength corresponding to a microscopic flaw related failure. From the data available, the specimen width and loading arm length had little effect on sigma(sub 3c). The inner radius was not expected to have a significant effect on sigma(sub 3c), but this conclusion could not be confirmed because of differences in laminate quality for each curve geometry. The thicker specimens had the lowest value of sigma(sub 3c) because of poor laminate quality.

  1. Drug Testing in Oral Fluid

    PubMed Central

    Drummer, Olaf H

    2006-01-01

    Over the last decade there have been considerable developments in the use of oral fluid (saliva) for drug testing. Oral fluid can provide a quick and non-invasive specimen for drug testing. However, its collection may be thwarted by lack of available fluid due to a range of physiological factors, including drug use itself. Food and techniques designed to stimulate production of oral fluid can also affect the concentration of drugs. Current applications are mainly focused on drugs of abuse testing in employees at workplaces where drug use has safety implications, in drivers of vehicles at the roadside and in other situations where drug impairment is suspected. Testing has included alcohol (ethanol) and a range of clinical tests eg antibodies to HIV, therapeutic drugs and steroids. Its main application has been for testing for drugs of abuse such as the amphetamines, cocaine and metabolites, opioids such as morphine, methadone and heroin, and for cannabis. Oral fluid concentrations of basic drugs such as the amphetamines, cocaine and some opioids are similar or higher than those in plasma. Tetrahydrocannabinol (THC), the major species present from cannabis use, displays similar concentrations in oral fluid compared to blood in the elimination phase. However, there is significant local absorption of the drug in the oral cavity which increases the concentrations for a period after use of drug. Depot effects occur for other drugs introduced into the body that allow local absorption, such as smoking of tobacco (nicotine), cocaine, amphetamines, or use of sub-lingual buprenorphine. Screening techniques are usually an adaptation of those used in other specimens, with an emphasis on the parent drug since this is usually the dominant species present in oral fluid. Confirmatory techniques are largely based on mass spectrometry (MS) with an emphasis on Liquid Chromatography-Mass Spectrometry (LC-MS), due to low sample volumes and the low detection limits required. Drug testing outside laboratory environments has become widespread and provides presumptive results within minutes of collection of specimens. This review focuses on the developments, particularly over the last 10 years, and outlines the roles and applications of testing for drugs in oral fluid, describes the difficulties associated with this form of testing and illustrates applications of oral fluid testing for specific drugs. PMID:17268583

  2. Reliability of fracture appearance measurement in the Charpy test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dixon, B.F.

    1994-12-31

    Despite conventional wisdom, the Charpy fracture appearance transition curve does not always coincide with the energy transition curve. Furthermore, unlike Charpy energy, fracture appearance tells how a specimen failed. It can therefore be used to meaningfully relate the results of Charpy testing to results of other toughness tests which may employ different geometries and loading rates. In order to address the question of consistency, a set of 20 specimens was prepared and used in a `round robin` survey. Results showed that agreement was greatest when operators are experienced, samples are close to fracture appearance transition, and simple, two-dimensional diagrams aremore » sued for assessment. It was also found that certain inconsistencies exist between various assessment techniques for Charpy fracture appearance. As a part of this work, fracture appearance curves were compared to energy impact curves for the Charpy test and a similar test, the Schnadt K{sub o} test, which uses a sharp pressed notch. It was found that energy and fracture appearance transition may differ by as much as 50{degrees}C in the Charpy test while the two curves coincided in the Schnadt test. In series of toughness tests on 132 steels, the average difference between Charpy energy transition and Schnade K{sub o} energy transition was about 27{degrees}C. This is believed to represent the difference in toughness between blunt and sharp notches in Charpy size specimens.« less

  3. Triaxial testing system for pressure core analysis using image processing technique

    NASA Astrophysics Data System (ADS)

    Yoneda, J.; Masui, A.; Tenma, N.; Nagao, J.

    2013-11-01

    In this study, a newly developed innovative triaxial testing system to investigate strength, deformation behavior, and/or permeability of gas hydrate bearing-sediments in deep sea is described. Transport of the pressure core from the storage chamber to the interior of the sealing sleeve of a triaxial cell without depressurization was achieved. An image processing technique was used to capture the motion and local deformation of a specimen in a transparent acrylic triaxial pressure cell and digital photographs were obtained at each strain level during the compression test. The material strength was successfully measured and the failure mode was evaluated under high confining and pore water pressures.

  4. Producing Zirconium Diboride Components with Complex, Near-Net Shape Geometries by Aqueous Room-Temperature Injection Molding

    NASA Technical Reports Server (NTRS)

    Wiesner, Valerie L.; Youngblood, Jeffrey; Trice, Rodney

    2014-01-01

    Room-temperature injection molding is proposed as a novel, low-cost and more energy efficient manufacturing process capable of forming complex-shaped zirconium diboride (ZrB2) parts. This innovative processing method utilized aqueous suspensions with high powder loading and a minimal amount (5 vol.) of water-soluble polyvinylpyrrolidone (PVP), which was used as a viscosity modifier. Rheological characterization was performed to evaluate the room-temperature flow properties of ZrB2-PVP suspensions. ZrB2 specimens were fabricated with high green body strength and were machinable prior to binder removal despite their low polymer content. After binder burnout and pressureless sintering, the bulk density and microstructure of specimens were characterized using Archimedes technique and scanning electron microscopy. X-Ray Diffraction was used to determine the phase compositions present in sintered specimens. Ultimate strength of sintered specimens will be determined using ASTM C1323-10 compressive C-ring test.

  5. Gigacycle fatigue behavior by ultrasonic nanocrystalline surface modification.

    PubMed

    Ahn, D G; Amanov, A; Cho, I S; Shin, K S; Pyoun, Y S; Lee, C S; Park, I G

    2012-07-01

    Nanocrystalline surface layer up to 84 microm in thick is produced on a specimen made of Al6061-T6 alloy by means of surface treatment called ultrasonic nanocrystalline surface modification (UNSM) technique. The refined grain size is produced in the top-layer and it is increased with increasing depth from the top surface. Vickers microhardness measurement for each nanocrystalline surface layer is performed and measurement results showed that the microhardness is increased from 116 HV up to 150 HV, respectively. In this study, fatigue behavior of Al6061-T6 alloy was studied up to 10(7)-10(9) cycles by using a newly developed ultrasonic fatigue testing (UFT) rig. The fatigue results of the UNSM-treated Al6061-T6 alloy specimens were compared with those of the untreated specimens. The microstructure of the untreated and UNSM-treated specimens was characterized by means of scanning electron microscopey (SEM) and transmission electron microscopey (TEM).

  6. Thermal annealing recovery of fracture toughness in HT9 steel after irradation to high doses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Byun, Thak Sang; Baek, Jong-Hyuk; Anderoglu, Osman

    2013-08-03

    The HT9 ferritic/martensitic steel with a nominal chemistry of Fe(bal.)–12%Cr–1%MoVW has been used as a primary core material for fast fission reactors such as FFTF because of its high resistance to radiationinduced swelling and embrittlement. Both static and dynamic fracture test results have shown that the HT9 steel can become brittle when it is exposed to high dose irradiation at a relatively low temperature 430 °C). This article aims at a comprehensive discussion on the thermal annealing recovery of fracture toughness in the HT9 steel after irradiation up to 3–148 dpa at 378–504 °C. A specimen reuse technique has beenmore » established and applied to this study: the fracture specimens were tested Charpy specimens or broken halves of Charpy bars (13 3 4 mm). The post-anneal fracture test results indicated that much of the radiation-induced damage can be recovered by a simple thermal annealing schedule: the fracture toughness was incompletely recovered by 550 °C annealing, while nearly complete or complete recovery occurred after 650 °C annealing. This indicates that thermal annealing is a feasible damage mitigation technique for the reactor components made of HT9 steel. The partial recovery is probably due to the non-removable microstructural damages such as void or gas bubble formation, elemental segregation and precipitation.« less

  7. A scanning electron microscope study and statistical analysis of adipocyte morphology in lipofilling: comparing the effects of harvesting and purification procedures with 2 different techniques.

    PubMed

    Rubino, Corrado; Mazzarello, Vittorio; Faenza, Mario; Montella, Andrea; Santanelli, Fabio; Farace, Francesco

    2015-06-01

    The aim of this study was to evaluate the effects on adipocyte morphology of 2 techniques of fat harvesting and of fat purification in lipofilling, considering that the number of viable healthy adipocytes is important in fat survival in recipient areas of lipofilling. Fat harvesting was performed in 10 female patients from flanks, on one side with a 2-mm Coleman cannula and on the other side with a 3-mm Mercedes cannula. Thirty milliliter of fat tissue from each side was collected and divided into three 10 mL syringes: A, B, and C. The fat inside syringe A was left untreated, the fat in syringe B underwent simple sedimentation, and the fat inside syringe C underwent centrifugation at 3000 rpm for 3 minutes. Each fat graft specimen was processed for examination under low-vacuum scanning electron microscope. Diameter (μ) and number of adipocytes per square millimeter and number of altered adipocytes per square millimeter were evaluated. Untreated specimens harvested with the 2 different techniques were first compared, then sedimented versus centrifuged specimens harvested with the same technique were compared. Statistical analysis was performed using Wilcoxon signed rank test. The number of adipocytes per square millimeter was statistically higher in specimens harvested with the 3-mm Mercedes cannula (P = 0.0310). The number of altered cells was statistically higher in centrifuged specimens than in sedimented ones using both methods of fat harvesting (P = 0.0080) with a 2-mm Coleman cannula and (P = 0.0050) with a 3-mm Mercedes cannula. Alterations in adipocyte morphology consisted in wrinkling of the membrane, opening of pore with leakage of oily material, reduction of cellular diameter, and total collapse of the cellular membrane. Fat harvesting by a 3-mm cannula results in a higher number of adipocytes and centrifugation of the harvested fat results in a higher number of morphologic altered cells than sedimentation.

  8. Effect of low-temperature degradation on the mechanical and microstructural properties of tooth-colored 3Y-TZP ceramics.

    PubMed

    Nakamura, K; Harada, A; Ono, M; Shibasaki, H; Kanno, T; Niwano, Y; Adolfsson, E; Milleding, P; Örtengren, U

    2016-01-01

    The aim of the present study was to evaluate the effects of low-temperature degradation (LTD) induced by autoclaving on the mechanical and microstructural properties of tooth-colored 3 mol% yttria-stabilized tetragonal zirconia polycrystals (3Y-TZP). In total, 162 disc-shaped 3Y-TZP specimens were prepared. Two-thirds of the specimens were shaded by either the infiltration or powder mixing methods while the remaining specimens were used without coloring. The specimens were autoclaved at 134 °C for 0, 10, and 100 h to induce LTD (n=18 for each group). Chemical compositions were analyzed with X-ray fluorescence spectroscopy. Biaxial flexural strength was measured using a piston-on-three-ball test. The surface fraction and penetration depth of the monoclinic phase were examined using X-ray diffraction and scanning electron microscopy, respectively. The tooth-colored 3Y-TZP specimens contained Fe2O3 and Er2O3 (infiltration technique), and Fe2O3 (powder mixing method) at concentrations of<0.5 wt%. The tooth-colored 3Y-TZP had higher strength than the non-colored material after 100 h of autoclaving. In terms of surface fraction and penetration depth, the generation of monoclinic phase was significantly lower in the tooth-colored 3Y-TZP than in the non-colored material. The tooth-colored 3Y-TZP possessed equivalent biaxial flexural strength to that of the non-colored material and higher resistance to LTD regardless of the coloring technique (infiltration technique or powder mixing method) when the coloring pigments were contained at concentrations used in the present study. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Comparative study of the surface characteristics, microstructure, and magnetic retentive forces of laser-welded dowel-keepers and cast dowel-keepers for use with magnetic attachments.

    PubMed

    Chao, Yonglie; Du, Li; Yang, Ling

    2005-05-01

    Information regarding the merits and problems associated with connecting a keeper to a dowel and coping using a laser welding technique has not been explored extensively in the dental literature. This in vitro study compared the surface characteristics, microstructure, and magnetic retentive forces for a dowel and coping-keeper mechanism fabricated using a laser welding process and a cast-to casting technique. Five cast-to and 6 laser-welded dowel and coping-keeper specimens were tested. Using 5 freestanding keepers as the control group, the surface characteristics and microstructures of the specimens were examined by means of stereomicroscopy, metallographic microscopy, and scanning electron microscopy (SEM). Energy-dispersive spectroscopic (EDS) microanalysis with SEM provided elemental concentration information for the test specimens. The vertical magnetic retentive forces (N) of the 3 groups were measured using a universal testing machine. The results were statistically compared using 1-way analysis of variance and the Newman-Keuls multiple range test (alpha =.05). The laser-welded dowel-keeper generally maintained its original surface smoothness as well as the original microstructure. Elements diffused readily through the fusion zone. The surface of the cast dowel-keeper became rough with the formation of an oxide layer, the microstructure changed, and there was only limited elemental diffusion in the fusion zone. The average vertical magnetic retentive force of the laser-welded group, the cast group, and the control group were 4.2 +/- 0.2 N, 3.8 +/- 0.3 N, and 5.6 +/- 0.3 N, respectively. Statistically significant differences in vertical magnetic retentive force were found between the control group and both the laser-welded and cast groups (P <.01). Compared with the cast dowel-keepers, the average vertical magnetic retentive force of the laser-welded dowel-keepers was significantly higher (P <.05). The laser welding technique had less influence on the surface characteristics, the microstructure, and the magnetic retentive forces of keepers relative to techniques that incorporate a keeper at the time of cast dowel and coping fabrication.

  10. Damage detection in composite materials using Lamb wave methods

    NASA Astrophysics Data System (ADS)

    Kessler, Seth S.; Spearing, S. Mark; Soutis, Constantinos

    2002-04-01

    Cost-effective and reliable damage detection is critical for the utilization of composite materials. This paper presents part of an experimental and analytical survey of candidate methods for in situ damage detection of composite materials. Experimental results are presented for the application of Lamb wave techniques to quasi-isotropic graphite/epoxy test specimens containing representative damage modes, including delamination, transverse ply cracks and through-holes. Linear wave scans were performed on narrow laminated specimens and sandwich beams with various cores by monitoring the transmitted waves with piezoceramic sensors. Optimal actuator and sensor configurations were devised through experimentation, and various types of driving signal were explored. These experiments provided a procedure capable of easily and accurately determining the time of flight of a Lamb wave pulse between an actuator and sensor. Lamb wave techniques provide more information about damage presence and severity than previously tested methods (frequency response techniques), and provide the possibility of determining damage location due to their local response nature. These methods may prove suitable for structural health monitoring applications since they travel long distances and can be applied with conformable piezoelectric actuators and sensors that require little power.

  11. Viral diagnoses using the rapid immunofluorescence technique and epidemiological implications of acute respiratory infections among children in different European countries

    PubMed Central

    Ørstavik, I.; Grandien, M.; Halonen, P.; Arstila, P.; Mordhorst, C. H.; Hornsleth, A.; Popow-Kraupp, T.; McQuillin, J.; Gardner, P. S.; Almeida, J.; Bricout, F.; Marques, A.

    1984-01-01

    From November 1978 to October 1981, a total of 7716 specimens of nasopharyngeal secretions were examined by the rapid immunofluorescence technique to determine the frequency of infections caused by the respiratory syncytial virus (RSV), influenza virus A, and parainfluenza viruses 1 and 3. The tests were carried out in six different virus laboratories located in Newcastle upon Tyne (England), Copenhagen, Oslo, Stockholm, Turku (Finland), and Vienna; laboratories in Lisbon and Paris participated in the study for shorter periods. The specimens were collected from infants and children less than 6 years of age who had been admitted to hospital with an acute respiratory infection. Standardized techniques and quality controlled reagents were used. At least one of the above viruses was detected in 1927 (25%) of the specimens: RSV in 1475, influenza virus A in 123, parainfluenza virus 1 in 110, and parainfluenza virus 3 in 237 specimens. Respiratory syncytial virus dominated in all centres, but in some Scandinavian centres distinct outbreaks due to this virus occurred only once or twice during the 3 years' study period. Three outbreaks of RSV were observed in Newcastle, but here an unprecedented delay of the first winter's epidemic occurred. The delay was associated with prolonged school closures in the area, and with a very early outbreak of influenza. Parainfluenza virus 3, which was predominantly a summer virus in Newcastle, was most frequently encountered during the colder months of the year in the other centres. PMID:6375886

  12. Mixing of thawed coagulation samples prior to testing: Is any technique better than another?

    PubMed

    Lima-Oliveira, Gabriel; Adcock, Dorothy M; Salvagno, Gian Luca; Favaloro, Emmanuel J; Lippi, Giuseppe

    2016-12-01

    Thus study was aimed to investigate whether the mixing technique could influence the results of routine and specialized clotting tests on post-thawed specimens. The sample population consisted of 13 healthy volunteers. Venous blood was collected by evacuated system into three 3.5mL tubes containing 0.109mmol/L buffered sodium citrate. The three blood tubes of each subject were pooled immediately after collection inside a Falcon 15mL tube, then mixed by 6 gentle end-over-end inversions, and centrifuged at 1500g for 15min. Plasma-pool of each subject was then divided in 4 identical aliquots. All aliquots were thawed after 2-day freezing -70°C. Immediately afterwards, the plasma of the four paired aliquots were treated using four different techniques: (a) reference procedure, entailing 6 gentle end-over-end inversions; (b) placing the sample on a blood tube rocker (i.e., rotor mixing) for 5min to induce agitation and mixing; (c) use of a vortex mixer for 20s to induce agitation and mixing; and (d) no mixing. The significance of differences against the reference technique for mixing thawed plasma specimens (i.e., 6 gentle end-over-end inversions) were assessed with paired Student's t-test. The statistical significance was set at p<0.05. As compared to the reference 6-time gentle inversion technique, statistically significant differences were only observed for fibrinogen, and factor VIII in plasma mixed on tube rocker. Some trends were observed in the remaining other cases, but the bias did not achieve statistical significance. We hence suggest that each laboratory should standardize the procedures for mixing of thawed plasma according to a single technique. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. The application of acoustic emission technique to fatigue crack measurement. [in aluminum alloys

    NASA Technical Reports Server (NTRS)

    Singh, J. J.; Davis, W. T.; Crews, J. H., Jr.

    1974-01-01

    The applicability of acoustic emission technique to measure fatigue cracks in aluminum alloy specimens was investigated. There are several variables, such as the metallurgical and the physical treatment of the specimen, that can affect the level of acoustic activity of a fatigue specimen. It is therefore recommended that the acoustic emission technique be supplemented by other nondestructive evaluation methods to obtain quantitative data on crack growth.

  14. Behavior of an MBT waste in monotonic triaxial shear tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhandari, Athma Ram, E-mail: athma.bhandari@beg.utexas.edu; Powrie, William, E-mail: w.powrie@soton.ac.uk

    2013-04-15

    Highlights: ► We studied the stress–strain–strength characteristics of an MBT waste. ► Rate of mobilization of strength with strain depends on initial density. ► Image analysis technique was used to determine whole-specimen displacement fields. ► Initial mode of deformation of a loose specimen is one-dimensional compression. ► Reinforcing elements enhance the resistance to lateral and volumetric deformation. - Abstract: Legislation in some parts of the world now requires municipal solid waste (MSW) to be processed prior to landfilling to reduce its biodegradability and hence its polluting potential through leachate and fugitive emission of greenhouse gases. This pre-processing may be achievedmore » through what is generically termed mechanical–biological-treatment (MBT). One of the major concerns relating to MBT wastes is that the strength of the material may be less than for raw MSW, owing to the removal of sheet, stick and string-like reinforcing elements during processing. Also, the gradual increase in mobilized strength over strains of 30% or so commonly associated with unprocessed municipal solid waste may not occur with treated wastes. This paper describes a series of triaxial tests carried out to investigate the stress–strain–strength characteristics of an MBT waste, using a novel digital image analysis technique for the determination of detailed displacement fields over the whole specimen. New insights gained into the mechanical behavior of MBT waste include the effect of density on the stress–strain response, the initial 1-D compression of lightly consolidated specimens, and the likely reinforcing effect of small sheet like particles remaining in the waste.« less

  15. Non-destructive investigation of thermoplastic reinforced composites

    DOE PAGES

    Hassen, Ahmed; Taheri, Hossein; Vaidya, Uday

    2016-05-09

    This paper studies various manufacturing defects in glass fiber/Polypropylene (PP) composite parts and their methods of detection. Foreign Object Inclusion (FOI) of different shapes, sizes, and materials were placed in a glass fiber/PP panel made by compression molding. The paper aims to characterize the fiber orientation and fiber related defects such as fiber waviness in the composite specimen. Comprehensive investigation for different Non Destructive Evaluation (NDE) techniques, namely X-ray radiography and Ultrasonic Testing (UT) techniques to trace and characterize the embedded defects and the composite texture are presented. Conventional X-ray radiography successfully identified the fiber orientation in two dimension (2-D)more » plane; however, information for the sample depth was not captured. The radiography techniques showed low relative errors for the defect size measurements (maximum error was below 9.5%) when compared to the ultrasonic techniques. Ultrasonic techniques were able to map all the embedded artificial defects. Phase Array (PA) ultrasonic technique was able to precisely locate the FOI in the glass fiber/PP specimen. Nerveless, the shape and size of the defects were not accurately determined due to the high signal attenuation and distortion characteristics of the E-glass fiber.« less

  16. [The diagnostic methods applied in mycology].

    PubMed

    Kurnatowska, Alicja; Kurnatowski, Piotr

    2008-01-01

    The systemic fungal invasions are recognized with increasing frequency and constitute a primary cause of morbidity and mortality, especially in immunocompromised patients. Early diagnosis improves prognosis, but remains a problem because there is lack of sensitive tests to aid in the diagnosis of systemic mycoses on the one hand, and on the other the patients only present unspecific signs and symptoms, thus delaying early diagnosis. The diagnosis depends upon a combination of clinical observation and laboratory investigation. The successful laboratory diagnosis of fungal infection depends in major part on the collection of appropriate clinical specimens for investigations and on the selection of appropriate microbiological test procedures. So these problems (collection of specimens, direct techniques, staining methods, cultures on different media and non-culture-based methods) are presented in article.

  17. Theoretical Evaluation of the Transient Response of Constant Head and Constant Flow-Rate Permeability Tests

    USGS Publications Warehouse

    Zhang, M.; Takahashi, M.; Morin, R.H.; Esaki, T.

    1998-01-01

    A theoretical analysis is presented that compares the response characteristics of the constant head and the constant flowrate (flow pump) laboratory techniques for quantifying the hydraulic properties of geologic materials having permeabilities less than 10-10 m/s. Rigorous analytical solutions that describe the transient distributions of hydraulic gradient within a specimen are developed, and equations are derived for each method. Expressions simulating the inflow and outflow rates across the specimen boundaries during a constant-head permeability test are also presented. These solutions illustrate the advantages and disadvantages of each method, including insights into measurement accuracy and the validity of using Darcy's law under certain conditions. The resulting observations offer practical considerations in the selection of an appropriate laboratory test method for the reliable measurement of permeability in low-permeability geologic materials.

  18. Structure and mechanical properties of Cresco-Ti laser-welded joints and stress analyses using finite element models of fixed distal extension and fixed partial prosthetic designs.

    PubMed

    Uysal, Hakan; Kurtoglu, Cem; Gurbuz, Riza; Tutuncu, Naki

    2005-03-01

    The Cresco-Ti System uses a laser-welded process that provides an efficient technique to achieve passive fit frameworks. However, mechanical behavior of the laser-welded joint under biomechanical stress factors has not been demonstrated. This study describes the effect of Cresco-Ti laser-welding conditions on the material properties of the welded specimen and analyzes stresses on the weld joint through 3-dimensional finite element models (3-D FEM) of implant-supported fixed dentures with cantilever extensions and fixed partial denture designs. Twenty Grade III (ASTM B348) commercially pure titanium specimens were machine-milled to the dimensions described in the EN10002-1 tensile test standard and divided into test (n = 10) and control (n = 10) groups. The test specimens were sectioned and laser-welded. All specimens were subjected to tensile testing to determine yield strength (YS), ultimate tensile strength (UTS), and percent elongation (PE). The Knoop micro-indentation test was performed to determine the hardness of all specimens. On welded specimens, the hardness test was performed at the welded surface. Data were analyzed with the Mann-Whitney U test and Student's t test (alpha=.05). Fracture surfaces were examined by scanning electron microscopy to characterize the mode of fracture and identify defects due to welding. Three-dimensional FEMs were created that simulated a fixed denture with cantilever extensions supported by 5 implants (M1) and a fixed partial denture supported by 2 implants (M2), 1 of which was angled 30 degrees mesio-axially. An oblique load of 400 N with 15 degrees lingual-axial inclinations was applied to both models at various locations. Test specimens fractured between the weld and the parent material. No porosities were observed on the fractured surfaces. Mean values for YS, UTS, PE, and Knoop hardness were 428 +/- 88 MPa, 574 +/- 113 MPa, 11.2 +/- 0.4%, 270 +/- 17 KHN, respectively, for the control group and 642 +/- 2 MPa, 772 +/- 72 MPa, 4.8 +/- 0.7%, 353 +/- 23 KHN, respectively, for the test group. The differences between the groups were significant for all mechanical properties ( P <.05). For both models, the FEA revealed that maximum principal stresses were concentrated at the framework-weld junction but did not exceed the UTS of the weld joint. Within the constraints of the finite element models, mechanical failure of the welded joint between the support and the framework may not be expected under biomechanical conditions simulated in this study.

  19. Acoustic emission of retrofitted fiber-wrapped columns

    NASA Astrophysics Data System (ADS)

    El Echary, Hazem; Mirmiran, Amir

    1998-03-01

    In recent years, fiber-wrapping technique has become increasingly popular for retrofitting of existing bridge pier columns in seismic zones. By the way of confinement, the external jacket enhances strength, ductility and shear performance of the column. However, since state of the concrete core is not visible from outside of the jacket, it is of great necessity to develop proper non-destructive methods to evaluate structural integrity of the column. Extensive research on FRP-confined concrete at the University of Central Florida has shown that failure of such hybrid columns is often accompanied by considerable audible and sub-audible noise, making acoustic emission (AE) a viable NDE technique for retrofitted columns. Acoustic emission from fiber-wrapped concrete specimens were monitored. A total of 24 concrete specimens with two types of construction (bonded and unbonded) and four different number of layers (1, 3, 5 and 7) were tested under uniaxial compression. All specimens were made of S-glass fabric and polyester resin with a core diameter of 6' and a length of 12'. Some of the specimens were subjected to cycles of loading and unloading to examine the presence of the Kaiser and the Felicity effects. A 4-channel AEDSP-32/16 (Mistras-2001) machine from Physical Acoustics Corp. was used for the experiments. Results indicate that AE energy and the number of AE counts can both be good representatives for the response of confined concrete. Further, plots of AE energy versus load follows the same bilinear trend that has been observed in the stress-strain response of such specimens. Finally, Felicity effect was observed in all composite specimens.

  20. Study of steel crack resistance under dynamic loading and temperature range 20-300 °C

    NASA Astrophysics Data System (ADS)

    Novikov, S. A.; Pushkov, V. A.

    1996-05-01

    The paper describes an experimental technique to measure crack resistance (plane stress-intensity factor) K1C of structural materials at loading rates up to 2ṡ106MPaṡm1/2ṡs-1 and temperatures 20-300 °C. This technique is based on the known Kolsky method using split Hopkinson bars. The tests were performed using compact WOL-specimens of steel St.3.

  1. Load Measurement in Structural Members Using Guided Acoustic Waves

    NASA Astrophysics Data System (ADS)

    Chen, Feng; Wilcox, Paul D.

    2006-03-01

    A non-destructive technique to measure load in structures such as rails and bridge cables by using guided acoustic waves is investigated both theoretically and experimentally. Robust finite element models for predicting the effect of load on guided wave propagation are developed and example results are presented for rods. Reasonably good agreement of experimental results with modelling prediction is obtained. The measurement technique has been developed to perform tests on larger specimens.

  2. Engine materials characterization and damage monitoring by using x ray technologies

    NASA Technical Reports Server (NTRS)

    Baaklini, George Y.

    1993-01-01

    X ray attenuation measurement systems that are capable of characterizing density variations in monolithic ceramics and damage due to processing and/or mechanical testing in ceramic and intermetallic matrix composites are developed and applied. Noninvasive monitoring of damage accumulation and failure sequences in ceramic matrix composites is used during room-temperature tensile testing. This work resulted in the development of a point-scan digital radiography system and an in situ x ray material testing system. The former is used to characterize silicon carbide and silicon nitride specimens, and the latter is used to image the failure behavior of silicon-carbide-fiber-reinforced, reaction-bonded silicon nitride matrix composites. State-of-the-art x ray computed tomography is investigated to determine its capabilities and limitations in characterizing density variations of subscale engine components (e.g., a silicon carbide rotor, a silicon nitride blade, and a silicon-carbide-fiber-reinforced beta titanium matrix rod, rotor, and ring). Microfocus radiography, conventional radiography, scanning acoustic microscopy, and metallography are used to substantiate the x ray computed tomography findings. Point-scan digital radiography is a viable technique for characterizing density variations in monolithic ceramic specimens. But it is very limited and time consuming in characterizing ceramic matrix composites. Precise x ray attenuation measurements, reflecting minute density variations, are achieved by photon counting and by using microcollimators at the source and the detector. X ray computed tomography is found to be a unique x ray attenuation measurement technique capable of providing cross-sectional spatial density information in monolithic ceramics and metal matrix composites. X ray computed tomography is proven to accelerate generic composite component development. Radiographic evaluation before, during, and after loading shows the effect of preexisting volume flaws on the fracture behavior of composites. Results from one-, three-, five-, and eight-ply ceramic composite specimens show that x ray film radiography can monitor damage accumulation during tensile loading. Matrix cracking, fiber-matrix debonding, fiber bridging, and fiber pullout are imaged throughout the tensile loading of the specimens. In situ film radiography is found to be a practical technique for estimating interfacial shear strength between the silicon carbide fibers and the reaction-bonded silicon nitride matrix. It is concluded that pretest, in situ, and post-test x ray imaging can provide greater understanding of ceramic matrix composite mechanical behavior.

  3. An experimental study on fracture mechanical behavior of rock-like materials containing two unparallel fissures under uniaxial compression

    NASA Astrophysics Data System (ADS)

    Huang, Yan-Hua; Yang, Sheng-Qi; Tian, Wen-Ling; Zeng, Wei; Yu, Li-Yuan

    2016-06-01

    Strength and deformability characteristics of rock with pre-existing fissures are governed by cracking behavior. To further research the effects of pre-existing fissures on the mechanical properties and crack coalescence process, a series of uniaxial compression tests were carried out for rock-like material with two unparallel fissures. In the present study, cement, quartz sand, and water were used to fabricate a kind of brittle rock-like material cylindrical model specimen. The mechanical properties of rock-like material specimen used in this research were all in good agreement with the brittle rock materials. Two unparallel fissures (a horizontal fissure and an inclined fissure) were created by inserting steel during molding the model specimen. Then all the pre-fissured rock-like specimens were tested under uniaxial compression by a rock mechanics servo-controlled testing system. The peak strength and Young's modulus of pre-fissured specimen all first decreased and then increased when the fissure angle increased from 0° to 75°. In order to investigate the crack initiation, propagation and coalescence process, photographic monitoring was adopted to capture images during the entire deformation process. Moreover, acoustic emission (AE) monitoring technique was also used to obtain the AE evolution characteristic of pre-fissured specimen. The relationship between axial stress, AE events, and the crack coalescence process was set up: when a new crack was initiated or a crack coalescence occurred, the corresponding axial stress dropped in the axial stress-time curve and a big AE event could be observed simultaneously. Finally, the mechanism of crack propagation under microscopic observation was discussed. These experimental results are expected to increase the understanding of the strength failure behavior and the cracking mechanism of rock containing unparallel fissures.

  4. Enterovirus D68 detection in respiratory specimens: Association with severe disease.

    PubMed

    Engelmann, Ilka; Fatoux, Marie; Lazrek, Mouna; Alidjinou, Enagnon K; Mirand, Audrey; Henquell, Cécile; Dewilde, Anny; Hober, Didier

    2017-07-01

    Molecular techniques increased the number of documented respiratory infections. In a substantial number of cases the causative agent remains undetected. Since August 2014, an increase in Enterovirus(EV)-D68 infections was reported. We aimed to investigate epidemiology and clinical relevance of EV-D68. From June to December 2014 and from September to December 2015, 803 and 847 respiratory specimens, respectively, were tested for respiratory viruses with a multiplex RT-PCR. This multiplex RT-PCR does not detect EV-D68. Therefore, 457 (2014) and 343 (2015) specimens with negative results were submitted to an EV-specific-RT-PCR. EV-positive specimens were tested with an EV-D68-specific-RT-PCR and genotyped. Eleven specimens of 2014 tested positive in the EV-specific-RT-PCR and of these seven were positive in the EV-D68-specific-RT-PCR. Typing confirmed these as EV-D68. Median age of EV-D68-positive patients was 3 years (1 month-91 years). Common symptoms included fever (n = 6, 86%), respiratory distress (n = 5, 71%), and cough (n = 4, 57%). All EV-D68-positive patients were admitted to hospital, 4 (57%) were admitted to intensive care units and 6 (86%) received oxygen. One patient suffered from acute flaccid paralysis. Seven specimens of 2015 were positive in the EV-specific-RT-PCR but negative in the EV-D68-specific-RT-PCR. In conclusion, use of an EV-specific-RT-PCR allowed us to detect EV-D68 circulation in autumn 2014 that was not detected by the multiplex RT-PCR and was associated with severe disease. © 2017 Wiley Periodicals, Inc.

  5. Aging aircraft NDI Development and Demonstration Center (AANC): An overview. [nondestructive inspection

    NASA Technical Reports Server (NTRS)

    Walter, Patrick L.

    1992-01-01

    A major center with emphasis on validation of nondestructive inspection (NDI) techniques for aging aircraft, the Aging Aircraft NDI Development and Demonstration Center (AANC), has been funded by the FAA at Sandia National Laboratories. The Center has been assigned specific tasks in developing techniques for the nondestructive inspection of static engine parts, assessing inspection reliability (POD experiments), developing testbeds for NDI validation, maintaining a FAA library of characterized aircraft structural test specimens, and leasing a hangar to house a high flight cycle transport aircraft for use as a full scale test bed.

  6. Evaluation of Heating Methods for Thermal Structural Testing of Large Structures

    NASA Technical Reports Server (NTRS)

    Daryabeigi, Kamran; Sikora, Joseph G.; Caldwell, Darrell L., Jr.

    1998-01-01

    An experimental study was conducted to evaluate different heating methods for thermal structural testing of large scale structures at temperatures up to 350 F as part of the High Speed Research program. The heating techniques evaluated included: radiative/convective, forced convective, and conductive. The radiative/convective heaters included finned strip heaters, and clear and frosted quartz lamps. The forced convective heating was accomplished by closed loop circulation of heated air. The conductive heater consisted of heating blankets. The tests were conducted on an 1/8 inch thick stainless steel plate in a custom-built oven. The criteria used for comparing the different heating methods included test specimen temperature uniformity, heater response time, and consumed power. The parameters investigated included air circulation in the oven, reflectance of oven walls, and the orientation of the test specimen and heaters (vertical and horizontal). It was found that reflectance of oven walls was not an important parameter. Air circulation was necessary to obtain uniform temperatures only for the vertically oriented specimen. Heating blankets provided unacceptably high temperature non-uniformities. Quartz lamps with internal air circulation had the lowest power consumption levels. Using frosted quartz lamps with closed loop circulation of cool air, and closed loop circulation of heated air provided the fastest response time.

  7. Rifampicin Resistance and Multidrug-Resistant Tuberculosis Detection Using Xpert MTB/RIF in Wuhan, China: A Retrospective Study.

    PubMed

    Huang, Hai; Zhang, Yanlin; Li, Sheng; Wang, Jun; Chen, Jun; Pan, Zhiyun; Gan, Hui

    2018-06-01

    The Xpert MTB/RIF test (Cepheid, Sunnyvale, CA) can simultaneously detect the Mycobacterium tuberculosis (MTB) complex DNA and rifampicin (RFP) resistance and can rapidly determine RFP resistance and predict multidrug-resistant tuberculosis (MDR-TB). In this study, we analyzed clinical examination results of a hospital specializing in TB treatment in Wuhan, Hubei, China, and examined the use of traditional culture and drug-sensitive test (DST) results as a gold standard to assess the diagnosis value of the Xpert MTB/RIF test in RFP resistance and MDR-TB. A total of 2,910 specimens were received in the Mycobacteriology Laboratory, Wuhan Pulmonary Hospital, for Xpert MTB/RIF testing between December 2013 and December 2014. After the results were reviewed by exclusion criteria, 1,066 Xpert test results were eligible for our study. We then compared the Xpert test results with sputum acid-fast bacilli staining, cultures, and DST results. In total, Xpert correctly identified 96.71% (147/152) RFP-resistant TB and 98.25% (898/914) RFP-sensitive TB specimens. Of the 147 RFP-resistant TB specimens detected by Xpert, 122 MDR-TB (82.99%) were identified by traditional culture and DST techniques. Xpert can simultaneously detect MTB and RFP resistance with high sensitivity and specificity. Thus, Xpert testing aids in saving a considerable amount of time in the diagnosis and treatment of MDR-TB.

  8. Method of fission heat flux determination from experimental data

    DOEpatents

    Paxton, Frank A.

    1999-01-01

    A method is provided for determining the fission heat flux of a prime specimen inserted into a specimen of a test reactor. A pair of thermocouple test specimens are positioned at the same level in the holder and a determination is made of various experimental data including the temperature of the thermocouple test specimens, the temperature of bulk water channels located in the test holder, the gamma scan count ratios for the thermocouple test specimens and the prime specimen, and the thicknesses of the outer clads, the fuel fillers, and the backclad of the thermocouple test specimen. Using this experimental data, the absolute value of the fission heat flux for the thermocouple test specimens and prime specimen can be calculated.

  9. Scaling of energy absorbing composite plates

    NASA Technical Reports Server (NTRS)

    Jackson, Karen; Morton, John; Traffanstedt, Catherine; Boitnott, Richard

    1992-01-01

    The energy absorption response and crushing characteristics of geometrically scaled graphite-Kevlar epoxy composite plates were investigated. Three different trigger mechanisms including chamfer, notch, and steeple geometries were incorporated into the plate specimens to initiate crushing. Sustained crushing was achieved with a simple test fixture which provided lateral support to prevent global buckling. Values of specific sustained crushing stress (SSCS) were obtained which were comparable to values reported for tube specimens from previously published data. Two sizes of hybrid plates were fabricated; a baseline or model plate, and a full-scale plate with in-plane dimensions scaled by a factor of two. The thickness dimension of the full-scale plates was increased using two different techniques; the ply-level method in which each ply orientation in the baseline laminate stacking sequence is doubled, and the sublaminate technique in which the baseline laminate stacking sequence is repeated as a group. Results indicated that the SSCS is independent of trigger mechanism geometry. However, a reduction in the SSCS of 10-25 percent was observed for the full-scale plates as compared with the baseline specimens, indicating a scaling effect in the crushing response.

  10. Scaling of energy absorbing composite plates

    NASA Technical Reports Server (NTRS)

    Jackson, Karen; Lavoie, J. Andre; Morton, John

    1994-01-01

    The energy absorption response and crushing characteristics of geometrically scaled graphite-Kevlar epoxy composite plates were investigated. Two different trigger mechanisms including notch, and steeple geometries were incorporated into the plate specimens to initiate crushing. Sustained crushing was achieved with a new test fixture which provided lateral support to prevent global buckling. Values of specific sustained crushing stress (SSCS) were obtained which were lower than values reported for tube specimens from previously published data. Two sizes of hybrid plates were fabricated; a baseline or model plate, and a full-scale plate with inplane dimensions scaled by a factor of two. The thickness dimension of the full-scale plates was increased using two different techniques: the ply-level method in which each ply orientation in the baseline laminate stacking sequence is doubled, and the sublaminate technique in which the baseline laminate stacking sequence is repeated as a group. Results indicated that the SSCS has a small dependence on trigger mechanism geometry. However, a reduction in the SSCS of 10-25% was observed for the full-scale plates as compared with the baseline specimens, indicating a scaling effect in the crushing response.

  11. Scaling of energy absorbing composite plates

    NASA Astrophysics Data System (ADS)

    Jackson, Karen; Morton, John; Traffanstedt, Catherine; Boitnott, Richard

    The energy absorption response and crushing characteristics of geometrically scaled graphite-Kevlar epoxy composite plates were investigated. Three different trigger mechanisms including chamfer, notch, and steeple geometries were incorporated into the plate specimens to initiate crushing. Sustained crushing was achieved with a simple test fixture which provided lateral support to prevent global buckling. Values of specific sustained crushing stress (SSCS) were obtained which were comparable to values reported for tube specimens from previously published data. Two sizes of hybrid plates were fabricated; a baseline or model plate, and a full-scale plate with in-plane dimensions scaled by a factor of two. The thickness dimension of the full-scale plates was increased using two different techniques; the ply-level method in which each ply orientation in the baseline laminate stacking sequence is doubled, and the sublaminate technique in which the baseline laminate stacking sequence is repeated as a group. Results indicated that the SSCS is independent of trigger mechanism geometry. However, a reduction in the SSCS of 10-25 percent was observed for the full-scale plates as compared with the baseline specimens, indicating a scaling effect in the crushing response.

  12. Fracture mechanics correlation of boron/aluminum coupons containing stress risers

    NASA Technical Reports Server (NTRS)

    Adsit, N. R.; Waszczak, J. P.

    1975-01-01

    The mechanical behavior of boron/aluminum near stress risers has been studied and reported. This effort was directed toward defining the tensile behavior of both unidirectional and (0/ plus or minus 45) boron/aluminum using linear elastic fracture mechanics (LEFM). The material used was 5.6-mil boron in 6061 aluminum, consolidated using conventional diffusion bonding techniques. Mechanical properties are reported for both unidirectional and (0/ plus or minus 45) boron/aluminum, which serve as control data for the fracture mechanics predictions. Three different flawed specimen types were studied. In each case the series of specimens remained geometrically similar to eliminate variations in finite size correction factors. The fracture data from these tests were reduced using two techniques. They both used conventional LEFM methods, but the existence of a characteristic flaw was assumed in one case and not the other. Both the data and the physical behavior of the specimens support the characteristic flaw hypothesis. Cracks were observed growing slowly in the (0/ plus or minus 45) laminates, until a critical crack length was reached at which time catastrophic failure occurred.

  13. High resolution SAW elastography for ex-vivo porcine skin specimen

    NASA Astrophysics Data System (ADS)

    Zhou, Kanheng; Feng, Kairui; Wang, Mingkai; Jamera, Tanatswa; Li, Chunhui; Huang, Zhihong

    2018-02-01

    Surface acoustic wave (SAW) elastography has been proven to be a non-invasive, non-destructive method for accurately characterizing tissue elastic properties. Current SAW elastography technique tracks generated surface acoustic wave impulse point by point which are a few millimeters away. Thus, reconstructed elastography has low lateral resolution. To improve the lateral resolution of current SAW elastography, a new method was proposed in this research. A M-B scan mode, high spatial resolution phase sensitive optical coherence tomography (PhS-OCT) system was employed to track the ultrasonically induced SAW impulse. Ex-vivo porcine skin specimen was tested using this proposed method. A 2D fast Fourier transform based algorithm was applied to process the acquired data for estimating the surface acoustic wave dispersion curve and its corresponding penetration depth. Then, the ex-vivo porcine skin elastogram was established by relating the surface acoustic wave dispersion curve and its corresponding penetration depth. The result from the proposed method shows higher lateral resolution than that from current SAW elastography technique, and the approximated skin elastogram could also distinguish the different layers in the skin specimen, i.e. epidermis, dermis and fat layer. This proposed SAW elastography technique may have a large potential to be widely applied in clinical use for skin disease diagnosis and treatment monitoring.

  14. Biomechanical testing simulation of a cadaver spine specimen: development and evaluation study.

    PubMed

    Ahn, Hyung Soo; DiAngelo, Denis J

    2007-05-15

    This article describes a computer model of the cadaver cervical spine specimen and virtual biomechanical testing. To develop a graphics-oriented, multibody model of a cadaver cervical spine and to build a virtual laboratory simulator for the biomechanical testing using physics-based dynamic simulation techniques. Physics-based computer simulations apply the laws of physics to solid bodies with defined material properties. This technique can be used to create a virtual simulator for the biomechanical testing of a human cadaver spine. An accurate virtual model and simulation would complement tissue-based in vitro studies by providing a consistent test bed with minimal variability and by reducing cost. The geometry of cervical vertebrae was created from computed tomography images. Joints linking adjacent vertebrae were modeled as a triple-joint complex, comprised of intervertebral disc joints in the anterior region, 2 facet joints in the posterior region, and the surrounding ligament structure. A virtual laboratory simulation of an in vitro testing protocol was performed to evaluate the model responses during flexion, extension, and lateral bending. For kinematic evaluation, the rotation of motion segment unit, coupling behaviors, and 3-dimensional helical axes of motion were analyzed. The simulation results were in correlation with the findings of in vitro tests and published data. For kinetic evaluation, the forces of the intervertebral discs and facet joints of each segment were determined and visually animated. This methodology produced a realistic visualization of in vitro experiment, and allowed for the analyses of the kinematics and kinetics of the cadaver cervical spine. With graphical illustrations and animation features, this modeling technique has provided vivid and intuitive information.

  15. Characterization of plastic deformation in a disk bend test

    NASA Astrophysics Data System (ADS)

    Byun, T. S.; Lee, E. H.; Hunn, J. D.; Farrell, K.; Mansur, L. K.

    2001-04-01

    A disk bend test technique has been developed to study deformation mechanisms as well as mechanical properties. In the disk bend test, a transmission electron microscopy (TEM) disk size specimen of 3 mm diameter ×0.25 mm thick is clamped around its rim in a circular holder and indented with a tungsten carbide ball of 1 mm diameter on its back face. AISI 316LN austenitic stainless steel and 9Cr-2WVTa ferritic/martensitic steel were selected as test materials. A model was developed to determine the average plastic strain and surface plastic strain in the disk bend test. The deformation regimes of the plastic strain versus deflection curves corresponded to those of the load versus deflection curves. The stress state of the disk bend deformation was analyzed for the two test materials and compared with those of other mechanical tests such as uniaxial tensile, compact tension, and ball indentation tests. Slip line features at the deformed surface and the corresponding TEM microstructures were examined for both tensile and disk bend specimens. Differences and similarities in deformation between the disk bend and the tensile tests are described.

  16. Use of a midstream clean catch mobile application did not lower urine contamination rates in an ED.

    PubMed

    Jacob, Mary S; Kulie, Paige; Benedict, Cameron; Ordoobadi, Alexander J; Sikka, Neal; Steinmetz, Erika; McCarthy, Melissa L

    2018-01-01

    Urine microscopy is a common test performed in emergency departments (EDs). Urine specimens can easily become contaminated by different factors, including the collection method. The midstream clean-catch (MSCC) collection technique is commonly used to reduce urine contamination. The urine culture contamination rate from specimens collected in our ED is 30%. We developed an instructional application (app) to show ED patients how to provide a MSCC urine sample. We hypothesized that ED patients who viewed our instructional app would have significantly lower urine contamination rates compared to patients who did not. We prospectively enrolled 257 subjects with a urinalysis and/or urine culture test ordered in the ED and asked them to watch our MSCC instructional app. After prospective enrollment was complete, we retrospectively matched each enrolled subject to an ED patient who did not watch the instructional app. Controls were matched to cases based on gender, type of urine specimen provided, ED visit date and shift. Urinalysis and urine culture contamination results were compared between the matched pairs using McNemar's test. The overall urine culture contamination rate of the 514 subjects was 38%. The majority of the matched pairs had a urinalysis (63%) or urinalysis plus urine culture (35%) test done. There were no significant differences in our urine contamination rates between the matched pairs overall or when stratified by gender, by prior knowledge of the clean catch process or by type of urine specimen. We did not see a lower contamination rate for patients who viewed our instructional app compared to patients who did not. It is possible that MSCC is not effective for decreasing urine specimen contamination. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Experimental technologies comparison for strain measurement of a composite main landing gear bay specimen

    NASA Astrophysics Data System (ADS)

    Viscardi, Massimo; Arena, Maurizio; Ciminello, Monica; Guida, Michele; Meola, Carosena; Cerreta, Pietro

    2018-03-01

    The development of advanced monitoring system for strain measurements on aeronautical components remain an important target both when related to the optimization of the lead-time and cost for part validation, allowing earlier entry into service, and when related to the implementation of advanced health monitoring systems dedicated to the in-service parameters verification and early stage detection of structural problems. The paper deals with the experimental testing of a composite samples set of the main landing gear bay for a CS-25 category aircraft, realized through an innovative design and production process. The test have represented a good opportunity for direct comparison of different strain measurement techniques: Strain Gauges (SG) and Fibers Bragg Grating (FBG) have been used as well as non-contact techniques, specifically the Digital Image Correlation (DIC) and Infrared (IR) thermography applied where possible in order to highlight possible hot-spot during the tests. The crucial points identification on the specimens has been supported by means of advanced finite element simulations, aimed to assessment of the structural strength and deformation as well as to ensure the best performance and the global safety of the whole experimental campaign.

  18. Cyclic creep and fatigue of TD-NiCr (thoria-dispersion-strengthened nickel-chromium), TD-Ni, and NiCr sheet at 1200 C

    NASA Technical Reports Server (NTRS)

    Hirschberg, M. H.; Spera, D. A.; Klima, S. J.

    1972-01-01

    The resistance of thin TD-NiCr sheet to cyclic deformation was compared with that of TD-Ni and a conventional nickel-chromium alloy. Strains were determined by a calibration technique which combines room-temperature strain gage and deflection measurements with high-temperature deflection measurements. Analyses of the cyclic tests using measured tensile and creep-rupture data indicated that the TD-NiCr and NiCr alloy specimens failed by a cyclic creep mechanism. The TD-Ni specimens, on the other hand, failed by a fatigue mechanism.

  19. Rapid Detection and Identification of Respiratory Viruses by Direct Immunofluorescence

    PubMed Central

    D'Alessio, Donn; Williams, Stanley; Dick, Elliot C.

    1970-01-01

    The use of fluorescein-conjugated antiserum against respiratory syncytial (RS) and parainfluenza 1 and 3 viruses was compared with conventional techniques in the rapid detection of virus in tissue cultures inoculated with pharyngeal specimens known to contain these viruses. Twenty-three specimens were tested: 9 RS, 8 parainfluenza 1, and 6 parainfluenza 3. The fluorescent-antibody technique (FA) detected virus in 52% of the tissue cultures in 24 hr, and, by 72 hr, 22 of the 23 cultures were FA-positive whereas only 5 were positive by conventional techniques. Additionally, conjugated antisera were prepared against herpes simplex, influenza A2, and adenovirus type 5. All conjugates stained only the homologous virus and were 100- to 10,000-fold more sensitive than conventional techniques in detecting descending dilutions of virus inocula by 24 hr. With the procedures described, several antisera could be conjugated and ready for use within 24 hr. Serum fractionation was by ammonium sulfate precipitation, and with the procedure outlined virtually complete recovery of the globulin fraction and elimination of all of the albumin were accomplished. Images PMID:4098101

  20. Containerless processing at high temperatures using acoustic levitation

    NASA Technical Reports Server (NTRS)

    Rey, C. A.; Merkley, D. R.; Hampton, S.; Devos, J.; Mapes-Riordan, D.; Zatarski, M.

    1991-01-01

    Advanced techniques are presented which facilitate the development of inert or reducing atmospheres in excess of 2000 K in order to improve processing of containerless capabilities at higher temperatures and to provide more contamination-free environments. Recent testing, in the laboratory and aboard the NASA KC-135 aircraft, of a high-temperature acoustic positioner demonstrated the effectiveness of a specimen motion damping system and of specimen spin control. It is found that stable positioning can be achieved under ambient and heated conditions, including the transient states of heat-up and cool-down. An incorporated high-temperature levitator was found capable of processing specimens of up to 6-mm diameter in a high-purity environment without the contaminating effects of a container at high temperatures and with relative quiescence.

  1. A proposed standard round compact specimen for plane strain fracture toughness testing

    NASA Technical Reports Server (NTRS)

    Underwood, J. H.; Newman, J. C., Jr.; Seeley, R. R.

    1980-01-01

    A round, disk-shaped specimen is proposed as a standard test specimen for addition to ASTM Test for Plane-Strain Fracture Toughness of Metallic Materials (E 399-78A). The specimen is diametrically cracked, and loaded in the same way as the existing standard compact specimen. Tests and analyses were performed to verify that the proposed round compact specimen and associated stress intensity factor K solution are appropriate for a standard plane strain fracture toughness test. The use of the round compact specimen for other fracture tests is described.

  2. Design and Performance Checks of the NPL Axial Heat Flow Apparatus

    NASA Astrophysics Data System (ADS)

    Wu, J.; Clark, J.; Stacey, C.; Salmon, D.

    2015-03-01

    This paper describes the design and performance checks of the NPL axial heat flow apparatus developed at the National Physical Laboratory for measurement of thermal conductivity. This apparatus is based on an absolute steady-state technique and is suitable for measuring specimens with thermal conductivities in the range from to and at temperatures between and . A uniform heat flow is induced in a cylindrical bar-shaped specimen that is firmly clamped between a guarded heater unit at the top and a water-cooled base. Heat is supplied at a known rate at the top end of the specimen by the heater unit and constrained to flow axially through the specimen by a surrounding edge-guard system, which is closely matched to the temperature gradient within the test specimen. The performance of this apparatus has been checked against existing NPL thermal-conductivity reference materials NPL 2S89 (based on Stainless Steel 310) and BSC Pure Iron (pure iron supplied by the British Steel Corporation with 99.96 % purity). The measured data produced by the newly designed NPL axial heat flow apparatus agree with the reference data for NPL 2S89 within 2 % and with that of BSC Pure Iron to within 3 % at temperatures from to . This apparatus is being used to provide accurate measurements to industrial and academic organizations and has also been used to develop a new range of NPL reference materials for checking other experimental techniques and procedures for thermal-conductivity measurements.

  3. In-situ monitoring of acoustic linear and nonlinear behavior of titanium alloys during cycling loading

    NASA Astrophysics Data System (ADS)

    Frouin, Jerome; Matikas, Theodore E.; Na, Jeong K.; Sathish, Shamachary

    1999-02-01

    An in-situ technique to measure sound velocity, ultrasonic attenuation and acoustic nonlinear property has been developed for characterization and early detection of fatigue damage in aerospace materials. A previous experiment using the f-2f technique on Ti-6Al-4V dog bone specimen fatigued at different stage of fatigue has shown that the material nonlinearity exhibit large change compared to the other ultrasonic parameter. Real-time monitoring of the nonlinearity may be a future tool to characterize early fatigue damage in the material. For this purpose we have developed a computer software and measurement technique including hardware for the automation of the measurement. New transducer holder and special grips are designed. The automation has allowed us to test the long-term stability of the electronics over a period of time and so proof of the linearity of the system. For the first time, a real-time experiment has been performed on a dog-bone specimen from zero fatigue al the way to the final fracture.

  4. Characterization of uranium bearing material using x-ray fluorescence and direct gamma-rays measurement techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mujaini, M., E-mail: madihah@uniten.edu.my; Chankow, N.; Yusoff, M. Z.

    2016-01-22

    Uranium ore can be easily detected due to various gamma-ray energies emitted from uranium daughters particularly from {sup 238}U daughters such as {sup 214}Bi, {sup 214}Pb and {sup 226}Ra. After uranium is extracted from uranium ore, only low energy gamma-rays emitted from {sup 235}U may be detected if the detector is placed in close contact to the specimen. In this research, identification and characterization of uranium bearing materials is experimentally investigated using direct measurement of gamma-rays from {sup 235}U in combination with the x-ray fluorescence (XRF) technique. Measurement of gamma-rays can be conducted by using high purity germanium (HPGe) detectormore » or cadmium telluride (CdTe) detector while a {sup 57}Coradioisotope-excited XRF spectrometer using CdTe detector is used for elemental analysis. The proposed technique was tested with various uranium bearing specimens containing natural, depleted and enriched uranium in both metallic and powder forms.« less

  5. Effect of External Post-tensioning in Retrofitting of RC Beams

    NASA Astrophysics Data System (ADS)

    Manisekar, R.

    2018-05-01

    There are large number of existing concrete bridges in distressed condition in India and other countries, and they need retrofitting solutions. External post-tensioning is a prime technique for bridge retrofitting. It is being applied for retrofitting of bridges in India and other countries. Although the technique is becoming popular in retrofitting, various issues regarding performance of post-retrofitting behaviour need to be studied in detail. RC beam specimens of rectangular section were distressed by means of cracks to a certain limit, and were retrofitted by external post-tensioning. Retrofitted specimens were tested to fail to study the post-retrofitting behaviour. Retrofitting has increased the ultimate load carrying capacity by 81% with reference to the control beam, and recovered the deflection. This paper intends to report the results of the experimental investigations, and conclusions.

  6. The Characteristics of an Antibacterial TiAgN Thin Film Coated by Physical Vapor Deposition Technique.

    PubMed

    Kang, Byeong-Mo; Jeong, Woon-Jo; Park, Gye-Choon; Yoon, Dong-Joo; Ahn, Ho-Geun; Lim, Yeong-Seog

    2015-08-01

    In this work, we found the characteristics of an antibacterial TiAgN thin film coated on the pure titanium specimen via the physical vapor deposition process (PVD). TiAgN thin films were coated using TiAg alloy targets by arc ion plating method. Changing the process parameters, the surface analysis of TiAgN thin film was observed by FE-SEM and the force of adhesion was measured with Scratch Tester. The proliferation of human gingival fibroblast (HGF) cells was examined by XTT test assay and the antibacterial properties were investigated by culturing Streptococus Mutans (KCTC 3065) using paper disk techniques. At the result of experiment, cytotoxic effects were not found and the antibacterial effects against Streptococus Mutans were appeared over 5 wt% TiAgN specimens.

  7. Uniaxial experimental study of the acoustic emission and deformation behavior of composite rock based on 3D digital image correlation (DIC)

    NASA Astrophysics Data System (ADS)

    Cheng, Jian-Long; Yang, Sheng-Qi; Chen, Kui; Ma, Dan; Li, Feng-Yuan; Wang, Li-Ming

    2017-12-01

    In this paper, uniaxial compression tests were carried out on a series of composite rock specimens with different dip angles, which were made from two types of rock-like material with different strength. The acoustic emission technique was used to monitor the acoustic signal characteristics of composite rock specimens during the entire loading process. At the same time, an optical non-contact 3D digital image correlation technique was used to study the evolution of axial strain field and the maximal strain field before and after the peak strength at different stress levels during the loading process. The effect of bedding plane inclination on the deformation and strength during uniaxial loading was analyzed. The methods of solving the elastic constants of hard and weak rock were described. The damage evolution process, deformation and failure mechanism, and failure mode during uniaxial loading were fully determined. The experimental results show that the θ = 0{°}-45{°} specimens had obvious plastic deformation during loading, and the brittleness of the θ = 60{°}-90{°} specimens gradually increased during the loading process. When the anisotropic angle θ increased from 0{°} to 90{°}, the peak strength, peak strain, and apparent elastic modulus all decreased initially and then increased. The failure mode of the composite rock specimen during uniaxial loading can be divided into three categories: tensile fracture across the discontinuities (θ = 0{°}-30{°}), sliding failure along the discontinuities (θ = 45{°}-75{°}), and tensile-split along the discontinuities (θ = 90{°}). The axial strain of the weak and hard rock layers in the composite rock specimen during the loading process was significantly different from that of the θ = 0{°}-45{°} specimens and was almost the same as that of the θ = 60{°}-90{°} specimens. As for the strain localization highlighted in the maximum principal strain field, the θ = 0{°}-30{°} specimens appeared in the rock matrix approximately parallel to the loading direction, while in the θ = 45{°}-90{°} specimens it appeared at the hard and weak rock layer interface.

  8. A technique for measuring dynamic friction coefficient under impact loading

    NASA Astrophysics Data System (ADS)

    Lin, Y. L.; Qin, J. G.; Chen, R.; Zhao, P. D.; Lu, F. Y.

    2014-09-01

    We develop a novel setup based on the split Hopkinson pressure bar technique to test the dynamic friction coefficient under impact loading. In the setup, the major improvement is that the end of the incident bar near the specimen is wedge-shaped, which results in a combined compressive and shear loading applied to the specimen. In fact, the shear loading is caused by the interfacial friction between specimen and bars. Therefore, when the two loading force histories are measured, the friction coefficient histories can be calculated without any assumptions and theoretical derivations. The geometry of the friction pairs is simple, and can be either cuboid or cylindrical. Regarding the measurements, two quartz transducers are used to directly record the force histories, and an optical apparatus is designed to test the interfacial slip movement. By using the setup, the dynamic friction coefficient of PTFE/aluminum 7075 friction pairs was tested. The time resolved dynamic friction coefficient and slip movement histories were achieved. The results show that the friction coefficient changes during the loading process, the average data of the relatively stable flat plateau section of the friction coefficient curves is 0.137, the maximum normal pressure is 52 MPa, the maximum relative slip velocity is 1.5 m/s, and the acceleration is 8400 m2/s. Furthermore, the friction test was simulated using an explicit FEM code LS-DYNA. The simulation results showed that the constant pressure and slip velocity can both be obtained with a wide flat plateau incident pulse. For some special friction pairs, normal pressure up to a few hundred MPa, interfacial slip velocities up to 10 m/s, and slip movement up to centimeter-level can be expected.

  9. A technique for measuring dynamic friction coefficient under impact loading.

    PubMed

    Lin, Y L; Qin, J G; Chen, R; Zhao, P D; Lu, F Y

    2014-09-01

    We develop a novel setup based on the split Hopkinson pressure bar technique to test the dynamic friction coefficient under impact loading. In the setup, the major improvement is that the end of the incident bar near the specimen is wedge-shaped, which results in a combined compressive and shear loading applied to the specimen. In fact, the shear loading is caused by the interfacial friction between specimen and bars. Therefore, when the two loading force histories are measured, the friction coefficient histories can be calculated without any assumptions and theoretical derivations. The geometry of the friction pairs is simple, and can be either cuboid or cylindrical. Regarding the measurements, two quartz transducers are used to directly record the force histories, and an optical apparatus is designed to test the interfacial slip movement. By using the setup, the dynamic friction coefficient of PTFE/aluminum 7075 friction pairs was tested. The time resolved dynamic friction coefficient and slip movement histories were achieved. The results show that the friction coefficient changes during the loading process, the average data of the relatively stable flat plateau section of the friction coefficient curves is 0.137, the maximum normal pressure is 52 MPa, the maximum relative slip velocity is 1.5 m/s, and the acceleration is 8400 m(2)/s. Furthermore, the friction test was simulated using an explicit FEM code LS-DYNA. The simulation results showed that the constant pressure and slip velocity can both be obtained with a wide flat plateau incident pulse. For some special friction pairs, normal pressure up to a few hundred MPa, interfacial slip velocities up to 10 m/s, and slip movement up to centimeter-level can be expected.

  10. Modelling of Mechanical Behavior at High Strain Rate of Ti-6al-4v Manufactured By Means of Direct Metal Laser Sintering Technique

    NASA Astrophysics Data System (ADS)

    Iannitti, Gianluca; Bonora, Nicola; Gentile, Domenico; Ruggiero, Andrew; Testa, Gabriel; Gubbioni, Simone

    2017-06-01

    In this work, the mechanical behavior of Ti-6Al-4V obtained by additive manufacturing technique was investigated, also considering the build direction. Dog-bone shaped specimens and Taylor cylinders were machined from rods manufactured by means of the EOSSINT M2 80 machine, based on Direct Metal Laser Sintering technique. Tensile tests were performed at strain rate ranging from 5E-4 s-1 to 1000 s-1 using an Instron electromechanical machine for quasistatic tests and a Direct-Tension Split Hopkinson Bar for dynamic tests. The mechanical strength of the material was described by a Johnson-Cook model modified to account for stress saturation occurring at high strain. Taylor cylinder tests and their corresponding numerical simulations were carried out in order to validate the constitutive model under a complex deformation path, high strain rates, and high temperatures.

  11. Research on fatigue cracking growth parameters in asphaltic mixtures using computed tomography

    NASA Astrophysics Data System (ADS)

    Braz, D.; Lopes, R. T.; Motta, L. M. G.

    2004-01-01

    Distress of asphalt concrete pavement due to repeated bending from traffic loads has been a well-recognized problem in Brazil. If it is assumed that fatigue cracking growth is governed by the conditions at the crack tip, and that the crack tip conditions can be characterized by the stress intensity factor, then fatigue cracking growth as a function of stress intensity range Δ K can be determined. Computed tomography technique is used to detect crack evolution in asphaltic mixtures which were submitted to fatigue tests. Fatigue tests under conditions of controlled stress were carried out using diametral compression equipment and repeat loading. The aim of this work is imaging several specimens at different stages of the fatigue tests. In preliminary studies it was noted that the trajectory of a crack was influenced by the existence of voids in the originally unloaded specimens. Cracks would first be observed in the central region of a specimen, propagating in the direction of the extremities. Analyzing the graphics, that represent the fatigue cracking growth (d c/d N) as a function of stress intensity factor (Δ K), it is noticed that the curve has practically shown the same behavior for all specimens at the same level of the static tension rupture stress. The experimental values obtained for the constants A and n (of the Paris-Erdogan Law) present good agreement with the results obtained by Liang and Zhou.

  12. Evaluation of powder metallurgy superalloy disk materials

    NASA Technical Reports Server (NTRS)

    Evans, D. J.

    1975-01-01

    A program was conducted to develop nickel-base superalloy disk material using prealloyed powder metallurgy techniques. The program included fabrication of test specimens and subscale turbine disks from four different prealloyed powders (NASA-TRW-VIA, AF2-1DA, Mar-M-432 and MERL 80). Based on evaluation of these specimens and disks, two alloys (AF2-1DA and Mar-M-432) were selected for scale-up evaluation. Using fabricating experience gained in the subscale turbine disk effort, test specimens and full scale turbine disks were formed from the selected alloys. These specimens and disks were then subjected to a rigorous test program to evaluate their physical properties and determine their suitability for use in advanced performance turbine engines. A major objective of the program was to develop processes which would yield alloy properties that would be repeatable in producing jet engine disks from the same powder metallurgy alloys. The feasibility of manufacturing full scale gas turbine engine disks by thermomechanical processing of pre-alloyed metal powders was demonstrated. AF2-1DA was shown to possess tensile and creep-rupture properties in excess of those of Astroloy, one of the highest temperature capability disk alloys now in production. It was determined that metallographic evaluation after post-HIP elevated temperature exposure should be used to verify the effectiveness of consolidation of hot isostatically pressed billets.

  13. In vitro biomechanical comparison of multistrand cables with conventional cervical stabilization.

    PubMed

    Weis, J C; Cunningham, B W; Kanayama, M; Parker, L; McAfee, P C

    1996-09-15

    The biomechanical stability of six different methods of cervical spine stabilization, three using multistrand cables, were evaluated in a bovine model. To quantify and compare the in vitro biomechanical properties of multistrand cables used for posterior cervical wiring to standard cervical fixation techniques. Fixation of the posterior cervical spine with monofilament stainless steel wire is a proven technique for stabilization of the cervical spine. Recently, multistrand braided cables have been used as a substitute for monofilament stainless steel wires. These cables, made of stainless steel, titanium, or polyethylene, are reported to be stronger, more flexible, and fatigue resistant than are monofilament wire based on mechanical testing. However, no in vitro biomechanical studies have been performed testing a standard posterior cervical wiring technique using multistrand cables. Thirty-six fresh frozen cervical calf spines consistent in size and age were mounted and fixed rigidly to isolate the C4-C5 motion segment. Six different reconstruction techniques were evaluated for Rogers' posterior cervical wiring technique using: 1) 20-gauge stainless steel monofilament wire, 2) stainless steel cable, 3) titanium cable, 4) polyethylene cables, 5) anterior locking plate construct with interbody graft, and 6) posterior plate construct. Six cervical spines were included in each group (n = 6), with each specimen statically evaluated under three stability conditions: 1) intact, 2) reconstructed, and 3) postfatigue. The instability model created before the reconstruction consisted of a distractive flexion Stage 3 injury at C4-C5. Nondestructive static biomechanical testing, performed on an material testing machine (MTS 858 Bionix test system, Minneapolis, MN), included axial compression, axial rotation, flexion-extension, and lateral bending. After reconstruction and static analysis, the specimens were fatigued for 1500 cycles and then statically retested. Data analysis included normalization of the reconstructed and postfatigue data to the intact condition. The calculated static parameters included operative functional unit stiffness and range of motion. Posterior cervical reconstruction with stainless steel monofilament wire proved inadequate under fatigue testing. Two of the six specimens failed with fatigue, and this construct permitted the greatest degree of flexion-extension motion after fatigue in comparison with all other constructs (P < 0.05). There were no significant differences in flexural stiffness or range of motion between stainless steel, titanium, or polyethylene cable constructs before or after fatigue testing. The posterior cervical plate constructs were the stiffest constructs under flexion, extension, and lateral bending modes, before and after fatigue testing (P < 0.05). Multistrand cables were superior to monofilament wire with fatigue testing using an in vitro calf cervical spine model. There were no failures or detectable differences in elongation after fatigue testing between the stainless steel, titanium, and polyethylene cables, as shown by the flexion-extension range of motion. The posterior cervical plate construct offered the greatest stability compared with all other constructs.

  14. [Technical questions of the transrectal specimen extraction].

    PubMed

    Lukovich, Péter; Csibi, Noémi; Bokor, Attila

    2016-03-01

    During laparoscopic partial colectomy the specimen can be extracted transrectally. This technique decreases the invasiveness of the surgery, because the abdominal wall incision is avoided. Premises of a new surgical technique are precise technical description as well as a favourable balance of advantages and disadvantages. In this paper the authors review the technique they apply and analyse their first results. 45 laparoscopic bowel resections were performed by a multidisciplinary team between 16th April 2014 and 1st November 2015. Indication of surgery was endometriosis, and the specimen was extracted transrectally in 11 patients. Having ligated both bowel ends proximal and distal to the section infiltrated with endometriosis, and the proximal bowel secured with a laparoscopic bulldog. Then the bowel was resected and the specimen was extracted in a camera bag transrectally. A purse-string suture was placed into the proximal bowel end, and the anvil of the circular stapler--which was introduced transrectally--was inserted into the bowel. After closing the rectal stump, the anastomosis was performed with a circular stapler. We used this technique when the upper third of the rectum or sigmoid colon was infiltrated with endometriosis. The difference between the operation time of the two techniques (transabdominal vs. transrectal specimen extraction: 108 min vs. 118 min) was not significant. There was not difference in the WBC count between the first and second postoperative day, and there was not any anastomosis leakage detected either. By using the above technique, postoperative infections could have been reduced to minimum. Transrectal specimen extraction did not increase postoperative complication The authors believe this is a safe way of specimen extraction after partial colectomy.

  15. Flexural Properties of PLA Components Under Various Test Condition Manufactured by 3D Printer

    NASA Astrophysics Data System (ADS)

    Jaya Christiyan, K. G.; Chandrasekhar, U.; Venkateswarlu, K.

    2018-06-01

    Rapid Prototyping (RP) technologies have emerged as a fabrication method to obtain engineering components in the resent past. Desktop 3D printing, also referred as an additive layer manufacturing technology is a powerful method of RP technique that can fabricate 3 dimensional engineering components. In this method, 3D digital data is converted into real product. In the present investigation, Polylactic Acid (PLA) was considered as a starting material. Flexural strength of PLA material was evaluated using 3-point bend test, as per ASTM D790 standard. Specimens with flat (0°) and vertical (90°) orientation were considered. Moreover, layer thicknesses of 0.2, 0.25, and 0.3 mm were considered. To fabricate these specimens, printing speed of 38 and 52 mm/s was maintained. Nozzle diameter of 0.4 mm with 40 % of infill density were used. Based on the experimental results, it was observed that 0° orientation, 38 mm/s printing speed, and 0.2 mm layer thickness resulted maximum flexural strength, as compared to all other specimens. The improved flexural strength was due to the lower layer thickness (0.2 mm) specimens, as compared with other specimens made of 0.25 and 0.30 mm layer thicknesses. It was concluded that flexural strength properties were greatly influenced by lower the layer thickness, printing speed, and orientation.

  16. Strengthening of defected beam-column joints using CFRP.

    PubMed

    Mahmoud, Mohamed H; Afefy, Hamdy M; Kassem, Nesreen M; Fawzy, Tarek M

    2014-01-01

    This paper presents an experimental study for the structural performance of reinforced concrete (RC) exterior beam-column joints rehabilitated using carbon-fiber-reinforced polymer (CFRP). The present experimental program consists of testing 10 half-scale specimens divided into three groups covering three possible defects in addition to an adequately detailed control specimen. The considered defects include the absence of the transverse reinforcement within the joint core, insufficient bond length for the beam main reinforcement and inadequate spliced implanted column on the joint. Three different strengthening schemes were used to rehabilitate the defected beam-column joints including externally bonded CFRP strips and sheets in addition to near surface mounted (NSM) CFRP strips. The failure criteria including ultimate capacity, mode of failure, initial stiffness, ductility and the developed ultimate strain in the reinforcing steel and CFRP were considered and compared for each group for the control and the CFRP-strengthened specimens. The test results showed that the proposed CFRP strengthening configurations represented the best choice for strengthening the first two defects from the viewpoint of the studied failure criteria. On the other hand, the results of the third group showed that strengthening the joint using NSM strip technique enabled the specimen to outperform the structural performance of the control specimen while strengthening the joints using externally bonded CFRP strips and sheets failed to restore the strengthened joints capacity.

  17. Effects of Build Orientation on Surface Morphology and Bone Cell Activity of Additively Manufactured Ti6Al4V Specimens.

    PubMed

    Weißmann, Volker; Drescher, Philipp; Seitz, Hermann; Hansmann, Harald; Bader, Rainer; Seyfarth, Anika; Klinder, Annett; Jonitz-Heincke, Anika

    2018-05-29

    Additive manufacturing of lightweight or functional structures by selective laser beam (SLM) or electron beam melting (EBM) is widespread, especially in the field of medical applications. SLM and EBM processes were applied to prepare Ti6Al4V test specimens with different surface orientations (0°, 45° and 90°). Roughness measurements of the surfaces were conducted and cell behavior on these surfaces was analyzed. Hence, human osteoblasts were seeded on test specimens to determine cell viability (metabolic activity, live-dead staining) and gene expression of collagen type 1 (Col1A1), matrix metalloprotease (MMP) 1 and its natural inhibitor, TIMP1, after 3 and 7 days. The surface orientation of specimens during the manufacturing process significantly influenced the roughness. Surface roughness showed significant impact on cellular viability, whereas differences between the time points day 3 and 7 were not found. Collagen type 1 mRNA synthesis rates in human osteoblasts were enhanced with increasing roughness. Both manufacturing techniques further influenced the induction of bone formation process in the cell culture. Moreover, the relationship between osteoblastic collagen type 1 mRNA synthesis rates and specimen orientation during the building process could be characterized by functional formulas. These findings are useful in the designing of biomedical applications and medical devices.

  18. HAADF-STEM atom counting in atom probe tomography specimens: Towards quantitative correlative microscopy.

    PubMed

    Lefebvre, W; Hernandez-Maldonado, D; Moyon, F; Cuvilly, F; Vaudolon, C; Shinde, D; Vurpillot, F

    2015-12-01

    The geometry of atom probe tomography tips strongly differs from standard scanning transmission electron microscopy foils. Whereas the later are rather flat and thin (<20 nm), tips display a curved surface and a significantly larger thickness. As far as a correlative approach aims at analysing the same specimen by both techniques, it is mandatory to explore the limits and advantages imposed by the particular geometry of atom probe tomography specimens. Based on simulations (electron probe propagation and image simulations), the possibility to apply quantitative high angle annular dark field scanning transmission electron microscopy to of atom probe tomography specimens has been tested. The influence of electron probe convergence and the benefice of deconvolution of electron probe point spread function electron have been established. Atom counting in atom probe tomography specimens is for the first time reported in this present work. It is demonstrated that, based on single projections of high angle annular dark field imaging, significant quantitative information can be used as additional input for refining the data obtained by correlative analysis of the specimen in APT, therefore opening new perspectives in the field of atomic scale tomography. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Research on corrosion detection for steel reinforced concrete structures using the fiber optical white light interferometer sensing technique

    NASA Astrophysics Data System (ADS)

    Zhao, Xuefeng; Cui, Yanjun; Wei, Heming; Kong, Xianglong; Zhang, Pinglei; Sun, Changsen

    2013-06-01

    In this paper, a novel kind of steel rebar corrosion monitoring technique for steel reinforced concrete structures is proposed, designed, and tested. The technique is based on the fiber optical white light interferometer (WLI) sensing technique. Firstly, a feasibility test was carried out using an equal-strength beam for comparison of strain sensing ability between the WLI and a fiber Bragg grating (FBG). The comparison results showed that the sensitivity of the WLI is sufficient for corrosion expansion strain monitoring. Then, two WLI corrosion sensors (WLI-CSs) were designed, fabricated, and embedded into concrete specimens to monitor expansion strain caused by steel rebar corrosion. Their performance was studied in an accelerated electrochemical corrosion test. Experimental results show that expansion strain along the fiber optical coil winding area can be detected and measured accurately by the proposed sensor. The advantages of the proposed monitoring technique allow for quantitative corrosion expansion monitoring to be executed in real time for reinforced concrete structures and with low cost.

  20. Congenital Trypanosoma cruzi Transmission in Santa Cruz, Bolivia

    PubMed Central

    Bern, Caryn; Verastegui, Manuela; Gilman, Robert H.; LaFuente, Carlos; Galdos-Cardenas, Gerson; Calderon, Maritza; Pacori, Juan; Abastoflor, Maria del Carmen; Aparicio, Hugo; Brady, Mark F.; Ferrufino, Lisbeth; Angulo, Noelia; Marcus, Sarah; Sterling, Charles; Maguire, James H.

    2017-01-01

    Background We conducted a study of congenital Trypanosoma cruzi infection in Santa Cruz, Bolivia. Our objective was to apply new tools to identify weak points in current screening algorithms, and find ways to improve them. Methods Women presenting for delivery were screened by rapid and conventional serological tests. For infants of infected mothers, blood specimens obtained on days 0, 7, 21, 30, 90, 180, and 270 were concentrated and examined microscopically; serological tests were performed for the day 90, 180, and 270 specimens. Maternal and infant specimens, including umbilical tissue, were tested by polymerase chain reaction (PCR) targeting the kinetoplast minicircle and by quantitative PCR. Results Of 530 women, 154 (29%) were seropositive. Ten infants had congenital T. cruzi infection. Only 4 infants had positive results of microscopy evaluation in the first month, and none had positive cord blood microscopy results. PCR results were positive for 6 (67%) of 9 cord blood and 7 (87.5%) of 8 umbilical tissue specimens. PCR-positive women were more likely to transmit T. cruzi than were seropositive women with negative PCR results (P < .05). Parasite loads determined by quantitative PCR were higher for mothers of infected infants than for seropositive mothers of uninfected infants (P < .01). Despite intensive efforts, only 58% of at-risk infants had a month 9 specimen collected. Conclusions On the basis of the low sensitivity of microscopy in cord blood and high rate of loss to follow-up, we estimate that current screening programs miss one-half of all infected infants. Molecular techniques may improve early detection. PMID:19877966

  1. Normalization and sound zone determination in pulse thermographic NDE

    NASA Astrophysics Data System (ADS)

    Sripragash, Letchuman; Sundaresan, Mannur

    2017-02-01

    Thermographic nondestructive evaluation is quick and effective in detecting damage particularly for composite structures. Pulse thermographic nondestructive evaluation (TNDE) technique can potentially provide information on defect dimensions, such as the depth at which the defect is located. However, there are a number of extraneous variables that affect the signal obtained during these tests, such as non-uniformity in the heat pulse applied and differences in the emissivity of the surfaces from specimen to specimen. In addition, the identification of defect free areas in the image is a challenge. As in other NDE procedures calibration specimens would be of help, but calibration specimens corresponding to complex damage states in composite materials are difficult to fabricate. Results from validated numerical simulations can complement calibration specimens. However, the thermo-mechanical properties of the test object as well as the amount of heat energy absorbed in the field tests are not readily available for such models. This paper presents an extension of the thermographic signal reconstruction (TSR) procedure in which the temperature and the time scales are respectively normalized with equilibrium temperature and the break time. A benefit of such normalization is the ability to directly measure the defect depth as a fraction of plate thickness. In order to implement this normalization procedure, sound zone profile definition is required. A new approach for determining sound zone profile has been developed. Finally, determination of sound zone is affected by non-uniform heating, and a method of minimizing the effects of non-uniform heating is proposed. The performance of these new approaches on actual experimental results are presented.

  2. Biomechanical comparison of the human cadaveric pelvis with a fourth generation composite model.

    PubMed

    Girardi, Brandon L; Attia, Tarik; Backstein, David; Safir, Oleg; Willett, Thomas L; Kuzyk, Paul R T

    2016-02-29

    The use of cadavers for orthopaedic biomechanics research is well established, but presents difficulties to researchers in terms of cost, biosafety, availability, and ease of use. High fidelity composite models of human bone have been developed for use in biomechanical studies. While several studies have utilized composite models of the human pelvis for testing orthopaedic reconstruction techniques, few biomechanical comparisons of the properties of cadaveric and composite pelves exist. The aim of this study was to compare the mechanical properties of cadaveric pelves to those of the 4th generation composite model. An Instron ElectroPuls E10000 mechanical testing machine was used to load specimens with orientation, boundary conditions and degrees of freedom that approximated those occurring during the single legged phase of walking, including hip abductor force. Each specimen was instrumented with strain gauge rosettes. Overall specimen stiffness and principal strains were calculated from the test data. Composite specimens showed significantly higher overall stiffness and slightly less overall variability between specimens (composite K=1448±54N/m, cadaver K=832±62N/m; p<0.0001). Strains measured at specific sites in the composite models and cadavers were similar (but did differ) only when the applied load was scaled to overall construct stiffness. This finding regarding strain distribution and the difference in overall stiffness must be accounted for when using these composite models for biomechanics research. Altering the cortical wall thickness or tuning the elastic moduli of the composite material may improve future generations of the composite model. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Production of ultrafine grained aluminum by cyclic severe plastic deformation at ambient temperature

    NASA Astrophysics Data System (ADS)

    Bereczki, P.; Szombathelyi, V.; Krallics, G.

    2014-08-01

    In the present study the possibilities of grain refinement was investigated by applying large-scale of cyclic plastic deformation to aluminum at ambient temperature. The specimens are processed by multiaxial forging, which is one of the severe plastic deformation techniques. The aim of the experiments with the aluminum alloy 6082M was the determination of the equivalent stress and strain by multiaxial forging and the investigation of evolution of mechanical properties in relation with the accumulated deformation in the specimen. The mechanical properties of raw material was determined by plane strain compression test as well as by hardness measurements. The forming experiments were carried out on Gleeble 3800 physical simulator with MaxStrain System. The mechanical properties of the forged specimens were investigated by micro hardness measurements and tensile tests. A mechanical model, based on the principle of virtual velocities was developed to calculate the flow curves using the measured dimensional changes of the specimen and the measured force. With respect to the evolution of these curves, the cyclic growth of the flow stress can be observed at every characteristic points of the calculated flow curves. In accordance with this tendency, the evolution of the hardness along the middle cross section of the deformed volume has also a nonmonotonous characteristic and the magnitudes of these values are much smaller than by the specimen after plane strain compression test. This difference between the flow stresses respect to the monotonic and non-monotonic deformation can be also observed. The formed microstructure, after a 10-passes multiaxial forging process, consists of mainly equiaxial grains in the submicron grain scale.

  4. Thermal insulation testing method and apparatus

    NASA Technical Reports Server (NTRS)

    Fesmire, James E. (Inventor); Augustynowicz, Stanislaw D. (Inventor)

    2004-01-01

    A test apparatus and method of its use for evaluating various performance aspects of a test specimen is disclosed. A chamber within a housing contains a cold mass tank with a contact surface in contact with a first surface of a test specimen. The first surface of the test specimen is spaced from the second surface of the test specimen by a thickness. The second surface of the test specimen is maintained at a desired warm temperature. The first surface is maintained at a constant temperature by a liquid disposed within the cold mass tank. A boil-off flow rate of the gas is monitored and provided to a processor along with the temperature of the first and second surfaces of the test specimen. The processor calculates thermal insulation values of the test specimen including comparative values for heat flux and apparent thermal conductivity (k-value). The test specimen may be placed in any vacuum pressure level ranging from about 0.01 millitorr to 1,000,000 millitorr with different residual gases as desired. The test specimen may be placed under a mechanical load with the cold mass tank and another factors may be imposed upon the test specimen so as to simulate the actual use conditions.

  5. Thermal Insulation Testing Method and Apparatus

    NASA Technical Reports Server (NTRS)

    Fesmire, James E. (Inventor); Augustynowicz, Stanislaw D. (Inventor)

    2004-01-01

    A test apparatus and method of its use for evaluating various performance aspects of a test specimen is disclosed. A chamber within a housing contains a cold mass tank with a contact surface in contact with a first surface of a test specimen. The first surface of the test specimen is spaced from the second surface of the test specimen by a thickness. The second surface of the test specimen is maintained at a a constant temperature by a liquid disposed within the cold mass tank. A boil-off flow rate of the gas is monitored and provided to a processor along with the temperature of the first and second surfaces of the test specimen. The processor calculates thermal insulation values of the test specimen including comparative values for heat flux and apparent thermal conductivity k-value). The test specimen may be placed in any vacuum pressure level ranging from about 0.01 millitorr to 1,000,000 millitorr with different residual gases as desired. The test specimen may be placed under a mechanical load with the cold mass tank and another factors may be imposed upon the test specimen so as to simulate the actual use conditions.

  6. Inhibition of atmospheric corrosion of mild steel by sodium benzoate treatment

    NASA Astrophysics Data System (ADS)

    Kahraman, Ramazan

    2002-02-01

    The objective of this study was to evaluate the effectiveness of sodium benzoate as an inhibitor to slow down or prevent atmospheric corrosion/discoloration of the local mild steel during storage in the Arabian Gulf region. Test specimens were prepared from locally produced reinforcing steel products. The inhibitor solution was applied on steel specimens at a concentration of 100 mM for 1 day at room temperature. Wooden exposure racks were used to hold as-received and inhibitor-treated specimens during atmospheric exposure for different periods. Corrosion was evaluated through weight loss determination and electrochemical technique. As expected, the Arabian Gulf atmosphere was corrosive on the as-received local mild steel. On the other hand, treatment of steel with sodium benzoate lowered its corrosion rate during initial days of its exposure to atmosphere. However, atmospheric corrosion inhibition performance of sodium benzoate deteriorated with exposure time after 30 or more days of atmospheric exposure, and the corrosion rates of sodium benzoate-treated specimens reached that of the unprotected specimens at the end of 90 days of atmospheric exposure.

  7. Evaluation of canal filling after using two warm vertical gutta-percha compaction techniques in vivo: a preliminary study.

    PubMed

    Venturi, M

    2006-07-01

    To evaluate the quality of root canal filling when comparing two warm gutta-percha filling techniques in vivo. Human teeth were randomly divided into two equal groups, with 30 canals each. The root canals were shaped by hand and ProFile 0.04 rotary instruments to size 20-40 at the end-point and then filled with gutta-percha cones and AH-Plus. In group A, a traditional warm vertical compaction technique was performed using the Touch'n Heat, and back-filling with the Obtura II. In group B, a modified warm vertical compaction technique was used: small amounts of gutta-percha were removed, and the remaining most apical 3 mm were compacted with a 1 mm movement; then thermomechanical back-filling was performed. The teeth were extracted, stored in dye, cleared, and the distance between the apex and apical limit of the filling, linear dye penetration, and voids were measured from the buccal, lingual, mesial and distal perspective. The homogeneity of variance and means was verified using Levene's test and t-test. ANOVA and Dunnett post hoc test were used to establish the significance and to analyse the effects through multiple comparisons. Compared with the specimens of group A, the specimens of group B exhibited less mean linear dye penetration (P < 0.05), smaller void length (P < or = 0.05) and maximal width (P < or = 0.05) when examined in all four views, and a more precise filling when viewed from the buccal aspect (P < 0.05). The modified warm vertical compaction technique with apical back-filling produced a more effective and precise three-dimensional filling.

  8. ELECTRON MICROSCOPIC OBSERVATION OF SPECIMENS UNDER CONTROLLED GAS PRESSURE

    PubMed Central

    Heide, Hans Gunther

    1962-01-01

    A technique for encasing specimens in a thin gas layer during their observation in the Siemens Elmiskop I is described. All gases can be employed at pressures up to one atmosphere. Destruction of specimens can occur in the beam; all organic specimens are particularly liable to decompose. The conditions under which this can be avoided are given. A useful application of the technique allows one to prevent specimens from drying out, as they normally do in vacuum. A further application uses the controlled removal of carbon for thinning organic layers and for selective etching of organic materials. PMID:13905967

  9. Biomechanics of the Proximal Radius Following Drilling of the Bicipital Tuberosity to Mimic Cortical Button Distal Biceps Repair Technique.

    PubMed

    Oak, Nikhil R; Lien, John R; Brunfeldt, Alexander; Lawton, Jeffrey N

    2018-05-01

    A fracture through the proximal radius is a theoretical concern after cortical button distal biceps fixation in an active patient. The permanent, nonossified cortical defect and medullary tunnel is at risk during a fall eliciting rotational and compressive forces. We hypothesized that during simulated torsion and compression, in comparison with unaltered specimens, the cortical button distal biceps repair model would have decreased torsional and compressive strength and would fracture in the vicinity of the bicipital tuberosity bone tunnel. Sixteen fourth-generation composite radius Sawbones models were used in this controlled laboratory study. A bone tunnel was created through the bicipital tuberosity to mimic the exact bone tunnel, 8 mm near cortex and 3.2 mm far cortex, made for the BicepsButton distal biceps tendon repair. The radius was then prepared and mounted on either a torsional or compression testing device and compared with undrilled control specimens. Compression tests resulted in average failure loads of 9015.2 N in controls versus 8253.25 N in drilled specimens ( P = .074). Torsional testing resulted in an average failure torque of 27.3 Nm in controls and 19.3 Nm in drilled specimens ( P = .024). Average fracture angle was 35.1° in controls versus 21.1° in drilled. Gross fracture patterns were similar in compression testing; however, in torsional testing all fractures occurred through the bone tunnel in the drilled group. There are weaknesses in the vicinity of the bone tunnel in the proximal radius during biomechanical stress testing which may not be clinically relevant in nature. In cortical button fixation, distal biceps repairs creates a permanent, nonossified cortical defect with tendon interposed in the bone tunnel, which can alter the biomechanical properties of the proximal radius during compressive and torsional loading.

  10. Abnormal urinalysis results are common, regardless of specimen collection technique, in women without urinary tract infections.

    PubMed

    Frazee, Bradley W; Enriquez, Kayla; Ng, Valerie; Alter, Harrison

    2015-06-01

    Voided urinalysis to test for urinary tract infection (UTI) is prone to false-positive results for a number of reasons. Specimens are often collected at triage from women with any abdominal complaint, creating a low UTI prevalence population. Improper collection technique by the patient may affect the result. At least four indices, if positive, can indicate UTI. We examine the impact of voided specimen collection technique on urinalysis indicators of UTI and on urine culture contamination in disease-free women. In this crossover design, 40 menstrual-age female emergency department staff without UTI symptoms collected urine two ways: directly in a cup ("non-clean") and midstream clean catch ("ideal"). Samples underwent standard automated urinalysis and culture. Urinalysis indices and culture contamination were compared. The proportion of abnormal results from samples collected by "non-clean" vs. "ideal" technique, respectively, were: leukocyte esterase (>trace) 50%, 35% (95% confidence interval for difference -6% to 36%); nitrites (any) 2.5%, 2.5% (difference -2.5 to 2.5%); white blood cells (>5/high-powered field [HPF]) 50%, 27.5% (difference 4 to 41%); bacteria (any/HPF) 77.5%, 62.5%, (difference -7 to 37%); epithelial cells (>few) 65%, 30% (difference 13 to 56%); culture contamination (>1000 colony-forming units of commensal or >2 species) 77%, 63% (difference -5 to 35%). No urinalysis index was positively correlated with culture contamination. Contemporary automated urinalysis indices were often abnormal in a disease-free population of women, even using ideal collection technique. In clinical practice, such false-positive results could lead to false-positive UTI diagnosis. Only urine nitrite showed a high specificity. Culture contamination was common regardless of collection technique and was not predicted by urinalysis results. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Comparison of Directigen Group A Strep Test with a traditional culture technique for detection of group A beta-hemolytic streptococci.

    PubMed Central

    McCusker, J J; McCoy, E L; Young, C L; Alamares, R; Hirsch, L S

    1984-01-01

    The Directigen Group A Strep Test (DGAST), a new rapid method of detecting group A beta-hemolytic streptococci directly from throat swabs, was compared with a traditional culture technique for the detection of group A beta-hemolytic streptococci. Five hundred oropharyngeal swabs from pediatric and adult patients were cultured and then processed by using the DGAST. Of the 144 specimens positive by culture, 131 were DGAST positive (sensitivity, 90.9%). Of the 356 specimens negative by culture, 353 were DGAST negative (specificity, 99.2%). Twelve of the 13 false-negative DGAST results were from pediatric patients. One hundred isolates of non-group A beta-hemolytic streptococci were recovered, primarily groups C, F, and G. The DGAST is easy to perform, rapid, sensitive, and very specific for detection of group A beta-hemolytic streptococci directly from swabs. Supplementing the DGAST with a culture on a 5% sheep blood agar plate would enhance detection of group A beta-hemolytic streptococci, especially in pediatric patients. PMID:6386884

  12. Measurement of fracture properties of concrete at high strain rates

    PubMed Central

    Cendón, D. A.; Sánchez-Gálvez, V.; Gálvez, F.

    2017-01-01

    An analysis of the spalling technique of concrete bars using the modified Hopkinson bar was carried out. A new experimental configuration is proposed adding some variations to previous works. An increased length for concrete specimens was chosen and finite-element analysis was used for designing a conic projectile to obtain a suitable triangular impulse wave. The aim of this initial work is to establish an experimental framework which allows a simple and direct analysis of concrete subjected to high strain rates. The efforts and configuration of these primary tests, as well as the selected geometry and dimensions for the different elements, have been focused to achieve a simple way of identifying the fracture position and so the tensile strength of tested specimens. This dynamic tensile strength can be easily compared with previous values published in literature giving an idea of the accuracy of the method and technique proposed and the possibility to extend it in a near future to obtain other mechanical properties such as the fracture energy. The tests were instrumented with strain gauges, accelerometers and high-speed camera in order to validate the results by different ways. Results of the dynamic tensile strength of the tested concrete are presented. This article is part of the themed issue ‘Experimental testing and modelling of brittle materials at high strain rates’. PMID:27956510

  13. Accuracy of polimerase chain reaction for the diagnosis of pleural tuberculosis.

    PubMed

    Trajman, Anete; da Silva Santos Kleiz de Oliveira, Elen Fabricia; Bastos, Mayara Lisboa; Belo Neto, Epaminondas; Silva, Edgar Manoel; da Silva Lourenço, Maria Cristina; Kritski, Afrânio; Oliveira, Martha Maria

    2014-06-01

    Polymerase chain reaction (PCR)-based techniques to detect Mycobacterium tuberculosis DNA in respiratory specimens have been increasingly used to diagnose pulmonary tuberculosis. Their use in non-respiratory specimens to diagnose extrapulmonary tuberculosis is, however, controversial. In this study, we estimated the accuracy of three in-country commercialized PCR-based diagnostic techniques in pleural fluid samples for the diagnosis of pleural tuberculosis. Patients underwent thoracenthesis for diagnosis purposes; pleural fluid aliquots were frozen and subsequently submitted to two real time PCR tests (COBAS(®)TAQMAN(®)MTB and Xpert(®)MTB/Rif) and one conventional PCR test (Detect-TB(®)). Two different reference standards were considered: probable tuberculosis (based on clinical grounds) and confirmed tuberculosis (bacteriologically or histologically). Ninety-three patients were included, of whom 65 with pleural tuberculosis, 35 of them confirmed. Sensitivities were 29% for COBAS(®)TAQMAN(®)MTB, 3% for Xpert(®)MTB/Rif and 3% for Detect-TB(®); specificities were 86%, 100% and 97% respectively, considering confirmed tuberculosis. Considering all cases, sensitivities were 16%, 3% and 2%, and specificities, 86%, 100%, and 97%. Compared to the 95% sensitivity of adenosine deaminase, the most sensitive test for pleural tuberculosis, the sensitivities of the three PCR-based tests were very low. We conclude that at present, there is no major place for such tests in routine clinical use. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Experimental analysis of compaction of concrete and mortar

    NASA Astrophysics Data System (ADS)

    Burlion, Nicolas; Pijaudier-Cabot, Gilles; Dahan, Noël

    2001-12-01

    Compaction of concrete is physically a collapse of the material porous microstructure. It produces plastic strains in the material and, at the same time, an increase of its bulk modulus. This paper presents two experimental techniques aimed at obtaining the hydrostatic response of concrete and mortar. The first one is a uniaxial confined compression test which is quite simple to implement and allows to reach hydrostatic pressures of about 600 MPa. The specimen size is large enough so that concrete with aggregate sizes up to 16 mm can be tested. The second one is a true hydrostatic test performed on smaller (mortar) specimens. Test results show that the hydrostatic response of the material is elasto-plastic with a stiffening effect on both the tangent and unloading bulk moduli. The magnitude of the irreversible volumetric strains depends on the initial porosity of the material. This porosity can be related in a first approximation to the water/cement ratio. A comparison of the hydrostatic responses obtained from the two testing techniques on the same material show that the hydrostatic response of cementitious materials cannot be uncoupled from the deviatoric response, as opposed to the standard assumption in constitutive relations for metal alloys. This feature should be taken into account in the development of constitutive relations for concrete subjected to high confinement pressures which are needed in the modelling of impact problems.

  15. Detection, mapping, and quantification of single walled carbon nanotubes in histological specimens with photoacoustic microscopy.

    PubMed

    Avti, Pramod K; Hu, Song; Favazza, Christopher; Mikos, Antonios G; Jansen, John A; Shroyer, Kenneth R; Wang, Lihong V; Sitharaman, Balaji

    2012-01-01

    In the present study, the efficacy of multi-scale photoacoustic microscopy (PAM) was investigated to detect, map, and quantify trace amounts [nanograms (ng) to micrograms (µg)] of SWCNTs in a variety of histological tissue specimens consisting of cancer and benign tissue biopsies (histological specimens from implanted tissue engineering scaffolds). Optical-resolution (OR) and acoustic-resolution (AR)--Photoacoustic microscopy (PAM) was employed to detect, map and quantify the SWCNTs in a variety of tissue histological specimens and compared with other optical techniques (bright-field optical microscopy, Raman microscopy, near infrared (NIR) fluorescence microscopy). Both optical-resolution and acoustic-resolution PAM, allow the detection and quantification of SWCNTs in histological specimens with scalable spatial resolution and depth penetration. The noise-equivalent detection sensitivity to SWCNTs in the specimens was calculated to be as low as ∼7 pg. Image processing analysis further allowed the mapping, distribution, and quantification of the SWCNTs in the histological sections. The results demonstrate the potential of PAM as a promising imaging technique to detect, map, and quantify SWCNTs in histological specimens, and could complement the capabilities of current optical and electron microscopy techniques in the analysis of histological specimens containing SWCNTs.

  16. Oral Chlamydia trachomatis in Patients with Established Periodontitis

    PubMed Central

    Reed, Susan G.; Lopatin, Dennis E.; Foxman, Betsy; Burt, Brian A.

    2009-01-01

    Periodontitis is considered a consequence of a pathogenic microbial infection at the periodontal site and host susceptibility factors. Periodontal research supports the association of Actinobacillus actinomycetemcomitans, Porphyromonas gingivalis, Prevotella intermedia, and Bacteroides forsythus, and periodontitis; however causality has not been demonstrated. In pursuit of the etiology of periodontitis, we hypothesized that the intracellular bacteria, Chlamydia trachomatis, may play a role. As a first step, a cross-sectional study of dental school clinic patients with established periodontitis were assessed for the presence of C. trachomatis in the oral cavity, and in particular from the lining epithelium of periodontal sites. C. trachomatis was detected using a direct fluorescent monoclonal antibody (DFA) in oral specimens from 7% (6/87) of the patients. Four patients tested positive in specimens from the lining epithelium of diseased periodontal sites, one patient tested positive in healthy periodontal sites, and one patient tested positive in the general mucosal specimen. In conclusion, this study provides preliminary evidence of C. trachomatis in the periodontal sites. Planned studies include the use of a more precise periodontal epithelial cell collection device, the newer nucleic acid amplification techniques to detect C. trachomatis, and additional populations to determine the association of C. trachomatis and periodontitis. PMID:11218493

  17. Flexural strength of pure Ti, Ni-Cr and Co-Cr alloys submitted to Nd:YAG laser or TIG welding.

    PubMed

    Rocha, Rick; Pinheiro, Antônio Luiz Barbosa; Villaverde, Antonio Balbin

    2006-01-01

    Welding of metals and alloys is important to Dentistry for fabrication of dental prostheses. Several methods of soldering metals and alloys are currently used. The purpose of this study was to assess, using the flexural strength testing, the efficacy of two processes Nd:YAG laser and TIG (tungsten inert gas) for welding of pure Ti, Co-Cr and Ni-Cr alloys. Sixty cylindrical specimens were prepared (20 of each material), bisected and welded using different techniques. Four groups were formed (n=15). I: Nd:YAG laser welding; II- Nd:YAG laser welding using a filling material; III- TIG welding and IV (control): no welding (intact specimens). The specimens were tested in flexural strength and the results were analyzed statistically by one-way ANOVA. There was significant differences (p<0.001) among the non-welded materials, the Co-Cr alloy being the most resistant to deflection. Comparing the welding processes, significant differences (p<0.001) where found between TIG and laser welding and also between laser alone and laser plus filling material. In conclusion, TIG welding yielded higher flexural strength means than Nd:YAG laser welding for the tested Ti, Co-Cr and Ni-Cr alloys.

  18. Single-screw Fixation of Adolescent Salter-II Proximal Humeral Fractures: Biomechanical Analysis of the "One Pass Door Lock" Technique.

    PubMed

    Miller, Mark Carl; Redman, Christopher N; Mistovich, R Justin; Muriuki, Muturi; Sangimino, Mark J

    2017-09-01

    Pin fixation of Salter-II proximal humeral fractures in adolescents approaching skeletal maturity has potential complications that can be avoided with single-screw fixation. However, the strength of screw fixation relative to parallel and diverging pin fixation is unknown. To compare the biomechanical fixation strength between these fixation modalities, we used synthetic composite humeri, and then compared these results in composite bone with cadaveric humeri specimens. Parallel pinning, divergent pinning, and single-screw fixation repairs were performed on synthetic composite humeri with simulated fractures. Six specimens of each type were tested in axial loading and other 6 were tested in torsion. Five pair of cadaveric humeri were tested with diverging pins and single screws for comparison. Single-screw fixation was statistically stronger than pin fixation in axial and torsional loading in both composite and actual bone. There was no statistical difference between composite and cadaveric bone specimens. Single-screw fixation can offer greater stability to adolescent Salter-II fractures than traditional pinning. Single-screw fixation should be considered as a viable alternative to percutaneous pin fixation in transitional patients with little expected remaining growth.

  19. Effect of Bioactive Glass air Abrasion on Shear Bond Strength of Two Adhesive Resins to Decalcified Enamel

    PubMed Central

    Eshghi, Alireza; Khoroushi, Maryam; Rezvani, Alireza

    2014-01-01

    Objective: Bioactive glass air abrasion is a conservative technique to remove initial decalcified tissue and caries. This study examined the shear bond strength of composite resin to sound and decalcified enamel air-abraded by bioactive glass (BAG) or alumina using etch-and-rinse and self-etch adhesives. Materials and Methods: Forty-eight permanent molars were root-amputated and sectioned mesiodistally. The obtained 96 specimens were mounted in acrylic resin; the buccal and lingual surfaces remained exposed. A demineralizing solution was used to decalcify half the specimens. Both sound and decalcified specimens were divided into two groups of alumina and bioactive glass air abrasion. In each group, the specimens were subdivided into two subgroups of Clearfil SE Bond or OptiBond FL adhesives (n=12). Composite resin cylinders were bonded on enamel surfaces cured and underwent thermocycling. The specimens were tested for shear bond strength. Data were analyzed using SPSS 16.0 and three-way ANOVA (α=0.05). Similar to the experimental groups, the enamel surface of one specimen underwent SEM evaluation. Results: No significant differences were observed in composite resin bond strength subsequent to alumina or bioactive glass air abrasion preparation techniques (P=0.987). There were no statistically significant differences between the bond strength of etch-and-rinse and self-etch adhesive groups (P=1). Also, decalcified or intact enamel groups had no significant difference (P=0.918). However, SEM analysis showed much less enamel irregularities with BAG air abrasion compared to alumina air abrasion. Conclusion: Under the limitations of this study, preparation of both intact and decalcified enamel surfaces with bioactive glass air abrasion results in similar bond strength of composite resin in comparison with alumina air abrasion using etch-&-rinse or self-etch adhesives. PMID:25628694

  20. Fracture Toughness and Shear Strength of the Bonded Interface Between an Aluminium Alloy Skin and a FRP Patch

    NASA Astrophysics Data System (ADS)

    Kumar, Prashant; Shinde, Prakash Sonyabapu; Bhoyar, Gaurav

    2018-05-01

    The existing techniques to determine the fracture properties such as critical energy release rate in mode I (GIc) and mode II (GIIc) of an interface between two sheets of same material were modified to determine these properties between the sheets of dissimilar materials and thickness. In addition, the interface shear strength (ISS) was also determined. Experiments were carried out on the specimens made of a pre-cracked thin aluminium alloy skin and a Fiber reinforced polymer (FRP) patch. Two kinds of surface preparation of the aluminium skin were employed; (i) emery-paper roughened surface (ERS) and (ii) Sodium Hydroxide (NaOH) treated surface (NTS). GIc of ERS specimen was found to be 36.1 J/m2, while it was found to be much higher for NTS specimens, that is, 87.3 J/m2. GIIc was found to be 282.4 J/m2 for ERS specimens and much higher as 734.5 J/m2 for NTS specimens. ISS was determined as 32.6 MPa for ERS specimen and significantly higher for NTS specimen, that is, 44.5 MPa. The micrographs obtained from a field emission-scanning electron microscope (FE-SEM) and the surface roughness test showed that the NTS was significantly rougher than the ERS, explaining the higher values of all the three kinds of NTS specimens.

  1. Moisture determination in composite materials using positron lifetime techniques

    NASA Technical Reports Server (NTRS)

    Singh, J. J.; Holt, W. R.; Mock, W., Jr.

    1980-01-01

    A technique was developed which has the potential of providing information on the moisture content as well as its depth in the specimen. This technique was based on the dependence of positron lifetime on the moisture content of the composite specimen. The positron lifetime technique of moisture determination and the results of the initial studies are described.

  2. Dynamic measurements of thermophysical properties of metals and alloys at high temperatures by subsecond pulse heating techniques

    NASA Technical Reports Server (NTRS)

    Cezairliyan, Ared

    1993-01-01

    Rapid (subsecond) heating techniques developed at the National Institute of Standards and Technology for the measurements of selected thermophysical and related properties of metals and alloys at high temperatures (above 1000 C) are described. The techniques are based on rapid resistive self-heating of the specimen from room temperature to the desired high temperature in short times and measuring the relevant experimental quantities, such as electrical current through the specimen, voltage across the specimen, specimen temperature, length, etc., with appropriate time resolution. The first technique, referred to as the millisecond-resolution technique, is for measurements on solid metals and alloys in the temperature range 1000 C to the melting temperature of the specimen. It utilizes a heavy battery bank for the energy source, and the total heating time of the specimen is typically in the range of 100-1000 ms. Data are recorded digitally every 0.5 ms with a full-scale resolution of about one part in 8000. The properties that can be measured with this system are as follows: specific heat, enthalpy, thermal expansion, electrical resistivity, normal spectral emissivity, hemispherical total emissivity, temperature and energy of solid-solid phase transformations, and melting temperature (solidus). The second technique, referred to as the microsecond-resolution technique, is for measurements on liquid metals and alloys in the temperature range 1200 to 6000 C. It utilizes a capacitor bank for the energy source, and the total heating time of the specimen is typically in the range 50-500 micro-s. Data are recorded digitally every 0.5 micro-s with a full-scale resolution of about one part in 4000. The properties that can be measured with this system are: melting temperature (solidus and liquidus), heat of fusion, specific heat, enthalpy, and electrical resistivity. The third technique is for measurements of the surface tension of liquid metals and alloys at their melting temperature. It utilizes a modified millisecond-resolution heating system designed for use in a microgravity environment.

  3. Dynamic Mechanical Testing Techniques for Cortical and Cancellous Bone

    NASA Astrophysics Data System (ADS)

    Cloete, Trevor

    2017-06-01

    Bone fracture typically occurs as an impact loading event (sporting accidents, vehicle collisions), the simulation of which requires in-depth understanding of dynamic bone behavior. Bone is a natural composite material with a complex multi length-scale hierarchical microstructure. At a macroscopic level, it is classified into hard/compact cortical bone and soft/spongy cancellous (trabecular) bone, though both are low-impedance materials relative to steels. Cortical bone is predominant in long bones, while in complex bone geometries (joints, flat bones) a cancellous bone core supports a thin cortical shell. Bone has primarily been studied at quasi-static strain rates (ɛ˙ < 1s-1), with some dynamic studies (300s-1 <ɛ˙ < 3000s-1), but rarely at intermediate strain rates (ISR) (1s-1 <ɛ˙ < 100s-1). The data shows bone to be viscoelastic, which suggests that more dynamic and ISR data is required. Furthermore, bone exhibits quasi-brittle failure, with interrupted quasi-static tests revealing a strong microstructure dependence. However, bone specimens are typically destroyed during dynamic tests, leading to a lack of dynamic microstructural damage investigations. In this paper, a short overview of dynamic bone testing is presented to give context to the challenges of testing low impedance, strain-rate dependent, non-linear, visco-elastic-brittle materials. Recent state-of-the-art experimental developments in dynamic bone testing are reviewed, with emphasis on pulse shaping, momentum trapping and ISR testing. These techniques allow for dynamic bone testing at small strains and near-constant strain rates with intact specimen recovery. The results are compared to those obtained with varying strain rate tests. Interrupted dynamic test results with microstructural analysis of the recovered specimens are presented and discussed. The paper concludes with a discussion of the experimental and modeling challenges that lie ahead in the field of dynamic bone behavior. The financial assistance of the National Research Foundation and the University of Cape Town towards this research is hereby acknowledged. Opinions expressed and conclusions arrived at are those of the author alone.

  4. Biomechanical evaluation of knotless anatomical double-layer double-row rotator cuff repair: a comparative ex vivo study.

    PubMed

    Hepp, Pierre; Osterhoff, Georg; Engel, Thomas; Marquass, Bastian; Klink, Thomas; Josten, Christoph

    2009-07-01

    The layered configuration of the rotator cuff tendon is not taken into account in classic rotator cuff tendon repair techniques. The mechanical properties of (1) the classic double-row technique, (2) a double-layer double-row (DLDR) technique in simple suture configuration, and (3) a DLDR technique in mattress suture configuration are significantly different. Controlled laboratory study. Twenty-four sheep shoulders were assigned to 3 repair groups of full-thickness infraspinatus tears: group 1, traditional double-row repair; group 2, DLDR anchor repair with simple suture configuration; and group 3, DLDR knotless repair with mattress suture configuration. After ultrasound evaluation of the repair, each specimen was cyclically loaded with 10 to 100 N for 50 cycles. Each specimen was then loaded to failure at a rate of 1 mm/s. There were no statistically significant differences among the 3 testing groups for the mean footprint area. The cyclic loading test revealed no significant difference among the 3 groups with regard to elongation. For the load-to-failure test, groups 2 and 3 showed no differences in ultimate tensile load when compared with group 1. However, when compared to group 2, group 3 was found to have significantly higher values regarding ultimate load, ultimate elongation, and energy absorbed. The DLDR fixation techniques may provide strength of initial repair comparable with that of commonly used double-row techniques. When compared with the knotless technique with mattress sutures, simple suture configuration of DLDR repair may be too weak. Knotless DLDR rotator cuff repair may (1) restore the footprint by the use of double-row principles and (2) enable restoration of the shape and profile. Double-layer double-row fixation in mattress suture configuration has initial fixation strength comparable with that of the classic double-row fixation and so may potentially improve functional results of rotator cuff repair.

  5. Preparation of refractory cermet structures for lithium compatibility testing

    NASA Technical Reports Server (NTRS)

    Heestand, R. L.; Jones, R. A.; Wright, T. R.; Kizer, D. E.

    1973-01-01

    High-purity nitride and carbide cermets were synthesized for compatability testing in liquid lithium. A process was developed for the preparation of high-purity hafnium nitride powder, which was subsequently blended with tungsten powder or tantalum nitride and tungsten powders and fabricated into 3 in diameter billets by uniaxial hot pressing. Specimens were then cut from the billets for compatability testing. Similar processing techniques were applied to produce hafnium carbide and zirconium carbide cermets for use in the testing program. All billets produced were characterized with respect to chemistry, structure, density, and strength properties.

  6. A Profilometry-Based Dentifrice Abrasion Method for V8 Brushing Machines Part III: Multi-Laboratory Validation Testing of RDA-PE.

    PubMed

    Schneiderman, Eva; Colón, Ellen L; White, Donald J; Schemehorn, Bruce; Ganovsky, Tara; Haider, Amir; Garcia-Godoy, Franklin; Morrow, Brian R; Srimaneepong, Viritpon; Chumprasert, Sujin

    2017-09-01

    We have previously reported on progress toward the refinement of profilometry-based abrasivity testing of dentifrices using a V8 brushing machine and tactile or optical measurement of dentin wear. The general application of this technique may be advanced by demonstration of successful inter-laboratory confirmation of the method. The objective of this study was to explore the capability of different laboratories in the assessment of dentifrice abrasivity using a profilometry-based evaluation technique developed in our Mason laboratories. In addition, we wanted to assess the interchangeability of human and bovine specimens. Participating laboratories were instructed in methods associated with Radioactive Dentin Abrasivity-Profilometry Equivalent (RDA-PE) evaluation, including site visits to discuss critical elements of specimen preparation, masking, profilometry scanning, and procedures. Laboratories were likewise instructed on the requirement for demonstration of proportional linearity as a key condition for validation of the technique. Laboratories were provided with four test dentifrices, blinded for testing, with a broad range of abrasivity. In each laboratory, a calibration curve was developed for varying V8 brushing strokes (0, 4,000, and 10,000 strokes) with the ISO abrasive standard. Proportional linearity was determined as the ratio of standard abrasion mean depths created with 4,000 and 10,000 strokes (2.5 fold differences). Criteria for successful calibration within the method (established in our Mason laboratory) was set at proportional linearity = 2.5 ± 0.3. RDA-PE was compared to Radiotracer RDA for the four test dentifrices, with the latter obtained by averages from three independent Radiotracer RDA sites. Individual laboratories and their results were compared by 1) proportional linearity and 2) acquired RDA-PE values for test pastes. Five sites participated in the study. One site did not pass proportional linearity objectives. Data for this site are not reported at the request of the researchers. Three of the remaining four sites reported herein tested human dentin and all three met proportional linearity objectives for human dentin. Three of four sites participated in testing bovine dentin and all three met the proportional linearity objectives for bovine dentin. RDA-PE values for test dentifrices were similar between sites. All four sites that met proportional linearity requirement successfully identified the dentifrice formulated above the industry standard 250 RDA (as RDA-PE). The profilometry method showed at least as good reproducibility and differentiation as Radiotracer assessments. It was demonstrated that human and bovine specimens could be used interchangeably. The standardized RDA-PE method was reproduced in multiple laboratories in this inter-laboratory study. Evidence supports that this method is a suitable technique for ISO method 11609 Annex B.

  7. Diagnostic testing for Giardia infections.

    PubMed

    Heyworth, Martin F

    2014-03-01

    The traditional method for diagnosing Giardia infections involves microscopic examination of faecal specimens for Giardia cysts. This method is subjective and relies on observer experience. From the 1980s onwards, objective techniques have been developed for diagnosing Giardia infections, and are superseding diagnostic techniques reliant on microscopy. Detection of Giardia antigen(s) by immunoassay is the basis of commercially available diagnostic kits. Various nucleic acid amplification techniques (NAATs) can demonstrate DNA of Giardia intestinalis, and have the potential to become standard approaches for diagnosing Giardia infections. Of such techniques, methods involving either fluorescent microspheres (Luminex) or isothermal amplification of DNA (loop-mediated isothermal amplification; LAMP) are especially promising.

  8. Formability and macroscopic shearing of a titanium alloy Ti-6Al-4V under channel die compression

    NASA Astrophysics Data System (ADS)

    Francillette, Henri; Garand, Christian

    2017-10-01

    The mechanical behavior of Ti-6Al-4V is analyzed using channel die compression tests at room temperature. Specimens were cut out from a starting sheet in order to consider samples with specific initial crystallographic textures. Three types of specimens are considered in the study using an angle θ defined with the initial directions LD0, TD0 and ND0 of the starting sheet. The following values of θ are considered : 0°, 45° and 90°. Plastic deformations up to 20% are considered. Several experimental techniques are used, namely optical microscopy, SEM and Xray diffraction for texture evolution. The true stress-strain curves are plotted and the shape change of the specimens is analyzed. A macroscopic shearing is observed for one the three types of initial textures considered, notably θ = 45°. To complete the study, the Taylor model is applied in order to compare the activation of the mechanisms of the α phase in the different specimens.

  9. Miniaturized side-viewing imaging probe for fluorescence lifetime imaging (FLIM): validation with fluorescence dyes, tissue structural proteins and tissue specimens

    PubMed Central

    Elson, D S; Jo, J A

    2007-01-01

    We report a side viewing fibre-based endoscope that is compatible with intravascular imaging and fluorescence lifetime imaging microscopy (FLIM). The instrument has been validated through testing with fluorescent dyes and collagen and elastin powders using the Laguerre expansion deconvolution technique to calculate the fluorescence lifetimes. The instrument has also been tested on freshly excised unstained animal vascular tissues. PMID:19503759

  10. Microstructures and Mechanical Properties of Co-Cr Dental Alloys Fabricated by Three CAD/CAM-Based Processing Techniques

    PubMed Central

    Kim, Hae Ri; Jang, Seong-Ho; Kim, Young Kyung; Son, Jun Sik; Min, Bong Ki; Kim, Kyo-Han; Kwon, Tae-Yub

    2016-01-01

    The microstructures and mechanical properties of cobalt-chromium (Co-Cr) alloys produced by three CAD/CAM-based processing techniques were investigated in comparison with those produced by the traditional casting technique. Four groups of disc- (microstructures) or dumbbell- (mechanical properties) specimens made of Co-Cr alloys were prepared using casting (CS), milling (ML), selective laser melting (SLM), and milling/post-sintering (ML/PS). For each technique, the corresponding commercial alloy material was used. The microstructures of the specimens were evaluated via X-ray diffractometry, optical and scanning electron microscopy with energy-dispersive X-ray spectroscopy, and electron backscattered diffraction pattern analysis. The mechanical properties were evaluated using a tensile test according to ISO 22674 (n = 6). The microstructure of the alloys was strongly influenced by the manufacturing processes. Overall, the SLM group showed superior mechanical properties, the ML/PS group being nearly comparable. The mechanical properties of the ML group were inferior to those of the CS group. The microstructures and mechanical properties of Co-Cr alloys were greatly dependent on the manufacturing technique as well as the chemical composition. The SLM and ML/PS techniques may be considered promising alternatives to the Co-Cr alloy casting process. PMID:28773718

  11. Multicenter Evaluation of the AMPLICOR and Automated COBAS AMPLICOR CT/NG Tests for Detection of Chlamydia trachomatis

    PubMed Central

    Van Der Pol, Barbara; Quinn, Thomas C.; Gaydos, Charlotte A.; Crotchfelt, Kimberly; Schachter, Julius; Moncada, Jeanne; Jungkind, D.; Martin, David H.; Turner, Buffy; Peyton, Cynthia; Jones, Robert B.

    2000-01-01

    The fully automated COBAS AMPLICOR CT/NG and semiautomated AMPLICOR CT/NG tests were evaluated in a multicenter trial for the ability to detect Chlamydia trachomatis infections. Test performance compared to that of culture was evaluated for 2,236 matched endocervical swab and urine specimens obtained from women and for 1,940 matched urethral swab and urine specimens obtained from men. Culture-negative, PCR-positive specimens that tested positive in a direct fluorescent-antibody test or in a confirmatory PCR test for an alternative target sequence were resolved as true positives. The overall prevalences of chlamydia were 2.4% in women and 7.2% in men. The COBAS AMPLICOR and AMPLICOR formats yielded concordant results for 98.1% of the specimens. With the infected patient as the reference standard, the resolved sensitivities of COBAS AMPLICOR were 89.7% for endocervical swab specimens, 89.2% for female urine specimens, 88.6% for male urethral swab specimens, and 90.3% for male urine specimens. When results were analyzed as if only a single test had been performed on a single specimen type, the resolved sensitivity was always higher. The resolved specificities of PCR were 99.4% for endocervical swab specimens, 99.0% for female urine specimens, 98.7% for male urethral swab specimens, and 98.4% for male urine specimens. The internal control revealed that 2.4% of the specimens were inhibitory when initially tested. Nevertheless, valid results were obtained for 98.6% of the specimens because 59.1% of the inhibitory specimens were not inhibitory when a second aliquot was tested. The COBAS AMPLICOR and AMPLICOR CT/NG tests for C. trachomatis exhibited equally high sensitivity and specificity with both urogenital swab and urine specimens and thus are well suited for screening for C. trachomatis infection. PMID:10699004

  12. Three Dimensional Constraint Effects on the Estimated (Delta)CTOD during the Numerical Simulation of Different Fatigue Threshold Testing Techniques

    NASA Technical Reports Server (NTRS)

    Seshadri, Banavara R.; Smith, Stephen W.

    2007-01-01

    Variation in constraint through the thickness of a specimen effects the cyclic crack-tip-opening displacement (DELTA CTOD). DELTA CTOD is a valuable measure of crack growth behavior, indicating closure development, constraint variations and load history effects. Fatigue loading with a continual load reduction was used to simulate the load history associated with fatigue crack growth threshold measurements. The constraint effect on the estimated DELTA CTOD is studied by carrying out three-dimensional elastic-plastic finite element simulations. The analysis involves numerical simulation of different standard fatigue threshold test schemes to determine how each test scheme affects DELTA CTOD. The American Society for Testing and Materials (ASTM) prescribes standard load reduction procedures for threshold testing using either the constant stress ratio (R) or constant maximum stress intensity (K(sub max)) methods. Different specimen types defined in the standard, namely the compact tension, C(T), and middle cracked tension, M(T), specimens were used in this simulation. The threshold simulations were conducted with different initial K(sub max) values to study its effect on estimated DELTA CTOD. During each simulation, the DELTA CTOD was estimated at every load increment during the load reduction procedure. Previous numerical simulation results indicate that the constant R load reduction method generates a plastic wake resulting in remote crack closure during unloading. Upon reloading, this remote contact location was observed to remain in contact well after the crack tip was fully open. The final region to open is located at the point at which the load reduction was initiated and at the free surface of the specimen. However, simulations carried out using the constant Kmax load reduction procedure did not indicate remote crack closure. Previous analysis results using various starting K(sub max) values and different load reduction rates have indicated DELTA CTOD is independent of specimen size. A study of the effect of specimen thickness and geometry on the measured DELTA CTOD for various load reduction procedures and its implication in the estimation of fatigue crack growth threshold values is discussed.

  13. Aqueous stress-corrosion cracking of high-toughness D6AC steel

    NASA Technical Reports Server (NTRS)

    Gilbreath, W. P.; Adamson, M. J.

    1976-01-01

    The crack growth behavior of D6AC steel as a function of stress intensity, stress and corrosion history, and test technique, under sustained load in filtered natural seawater, 3.3 per cent sodium chloride solution, and distilled water, was investigated. Reported investigations of D6AC were considered in terms of the present study with emphasis on thermal treatment, specimen configuration, fracture toughness, crack-growth rates, initiation period, and threshold. Both threshold and growth kinetics were found to be relatively insensitive to these test parameters. The apparent incubation period was dependent on technique, both detection sensitivity and precracking stress intensity level.

  14. Structural Anomalies Detected in Ceramic Matrix Composites Using Combined Nondestructive Evaluation and Finite Element Analysis (NDE and FEA)

    NASA Technical Reports Server (NTRS)

    Abdul-Aziz, Ali; Baaklini, George Y.; Bhatt, Ramakrishna T.

    2003-01-01

    Most reverse engineering approaches involve imaging or digitizing an object and then creating a computerized reconstruction that can be integrated, in three dimensions, into a particular design environment. The rapid prototyping technique builds high-quality physical prototypes directly from computer-aided design files. This fundamental technique for interpreting and interacting with large data sets is being used here via Velocity2 (an integrated image-processing software, ref. 1) using computed tomography (CT) data to produce a prototype three-dimensional test specimen model for analyses. A study at the NASA Glenn Research Center proposes to use these capabilities to conduct a combined nondestructive evaluation (NDE) and finite element analysis (FEA) to screen pretest and posttest structural anomalies in structural components. A tensile specimen made of silicon nitrite (Si3N4) ceramic matrix composite was considered to evaluate structural durability and deformity. Ceramic matrix composites are being sought as candidate materials to replace nickel-base superalloys for turbine engine applications. They have the unique characteristics of being able to withstand higher operating temperatures and harsh combustion environments. In addition, their low densities relative to metals help reduce component mass (ref. 2). Detailed three-dimensional volume rendering of the tensile test specimen was successfully carried out with Velocity2 (ref. 1) using two-dimensional images that were generated via computed tomography. Subsequent, three-dimensional finite element analyses were performed, and the results obtained were compared with those predicted by NDE-based calculations and experimental tests. It was shown that Velocity2 software can be used to render a three-dimensional object from a series of CT scan images with a minimum level of complexity. The analytical results (ref. 3) show that the high-stress regions correlated well with the damage sites identified by the CT scans and the experimental data. Furthermore, modeling of the voids collected via NDE offered an analytical advantage that resulted in more accurate assessments of the material s structural strength. The top figure shows a CT scan image of the specimen test section illustrating various hidden structural entities in the material and an optical image of the test specimen considered in this study. The bottom figure represents the stress response predicted from the finite element analyses (ref .3 ) for a selected CT slice where it clearly illustrates the correspondence of the high stress risers due to voids in the material with those predicted by the NDE. This study is continuing, and efforts are concentrated on improving the modeling capabilities to imitate the structural anomalies as detected.

  15. Effect of annealing procedure on the bonding of ceramic to cobalt-chromium alloys fabricated by rapid prototyping.

    PubMed

    Tulga, Ayca

    2018-04-01

    An annealing procedure is a heat treatment process to improve the mechanical properties of cobalt-chromium (Co-Cr) alloys. However, information is lacking about the effect of the annealing process on the bonding ability of ceramic to Co-Cr alloys fabricated by rapid prototyping. The purpose of this in vitro study was to evaluate the effects of the fabrication techniques and the annealing procedure on the shear bond strength of ceramic to Co-Cr alloys fabricated by different techniques. Ninety-six cylindrical specimens (10-mm diameter, 10-mm height) made of Co-Cr alloy were prepared by casting (C), milling (M), direct process powder-bed (LaserCUSING) with and without annealing (CL+, CL), and direct metal laser sintering (DMLS) with annealing (EL+) and without annealing (EL). After the application of ceramic to the metal specimens, the metal-ceramic bond strength was assessed using a shear force test at a crosshead speed of 0.5 mm/min. Shear bond strength values were statistically analyzed by 1-way ANOVA and Tukey multiple comparison tests (α=.05). Although statistically significant differences were found among the 3 groups (M, 29.87 ±2.06; EL, 38.92 ±2.04; and CL+, 40.93 ±2.21; P=.002), no significant differences were found among the others (P>.05). The debonding surfaces of all specimens exhibited mixed failure mode. These results showed that the direct process powder-bed method is promising in terms of metal-ceramic bonding ability. The manufacturing technique of Co-Cr alloys and the annealing process influence metal-ceramic bonding. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. Internal coating of zirconia restoration with silica-based ceramic improves bonding of resin cement to dental zirconia ceramic.

    PubMed

    Kitayama, Shuzo; Nikaido, Toru; Ikeda, Masaomi; Alireza, Sadr; Miura, Hiroyuki; Tagami, Junji

    2010-01-01

    Resin bonding to zirconia ceramic cannot be established by standard methods that are utilized for conventional silica-based dental ceramics. This study was aimed to examine the tensile bond strength of resin cement to zirconia ceramic using a new laboratory technique. Sixty-four zirconia ceramic specimens were air-abraded using Al2O3 particles and divided into two groups; the control group with no pretreatment (Control), and the group pretreated using the internal coating technique (INT), in which the surface of the zirconia specimens were thinly coated by fusing silica-based ceramic and air-abraded in the same manner. The specimens in each group were further divided into two subgroups according to the silane coupling agents applied; a mixture of dentin primer/silane coupling agent (Clearfil SE Bond Primer/Porcelain Bond Activator) or a newly developed single-component silane coupling agent (Clearfil Ceramic Primer). After bonding with dual-cured resin cement (Panavia F 2.0), they were stored in water for 24 h and half of them were additionally subjected to thermal cycling. The tensile bond strengths were tested using a universal testing machine. ANOVAs revealed significant influence of ceramic surface pretreatment (p<0.001), silane coupling agent (p<0.001) and thermal cycling (p<0.001); the INT coating technique significantly increased the bond strengths of resin cement to zirconia ceramic, whereas thermal cycling significantly decreased the bond strengths. The use of a single-component silane coupling agent demonstrated significantly higher bond strengths than that of a mixture of dentin primer/silane coupling agent. The internal coating of zirconia dental restorations with silica-based ceramic followed by silanization may be indicated in order to achieve better bonding for the clinical success.

  17. Full-field Strain Methods for Investigating Failure Mechanisms in Triaxial Braided Composites

    NASA Technical Reports Server (NTRS)

    Littell, Justin D.; Binienda, Wieslaw K.; Goldberg, Robert K.; Roberts, Gary D.

    2008-01-01

    Composite materials made with triaxial braid architecture and large tow size carbon fibers are beginning to be used in many applications, including composite aircraft and engine structures. Recent advancements in braiding technology have led to commercially viable manufacturing approaches for making large structures with complex shape. Although the large unit cell size of these materials is an advantage for manufacturing efficiency, the fiber architecture presents some challenges for materials characterization, design, and analysis. In some cases, the static load capability of structures made using these materials has been higher than expected based on material strength properties measured using standard coupon tests. A potential problem with using standard tests methods for these materials is that the unit cell size can be an unacceptably large fraction of the specimen dimensions. More detailed investigation of deformation and failure processes in large unit cell size triaxial braid composites is needed to evaluate the applicability of standard test methods for these materials and to develop alternative testing approaches. In recent years, commercial equipment has become available that enables digital image correlation to be used on a more routine basis for investigation of full field 3D deformation in materials and structures. In this paper, some new techniques that have been developed to investigate local deformation and failure using digital image correlation techniques are presented. The methods were used to measure both local and global strains during standard straight-sided coupon tensile tests on composite materials made with 12 and 24 k yarns and a 0/+60/-60 triaxial braid architecture. Local deformation and failure within fiber bundles was observed, and this local failure had a significant effect on global stiffness and strength. The matrix material had a large effect on local damage initiation for the two matrix materials used in this investigation. Premature failure in regions of the unit cell near the edge of the straight-sided specimens was observed for transverse tensile tests in which the braid axial fibers were perpendicular to the specimen axis and the bias fibers terminated on the cut edges in the specimen gage section. This edge effect is one factor that could contribute to a measured strength that is lower than the actual material strength in a structure without edge effects.

  18. Flash Diffusivity Technique Applied to Individual Fibers

    NASA Technical Reports Server (NTRS)

    Mayeaux, Brian; Yowell, Leonard; Wang, Hsin

    2007-01-01

    A variant of the flash diffusivity technique has been devised for determining the thermal diffusivities, and thus the thermal conductivities, of individual aligned fibers. The technique is intended especially for application to nanocomposite fibers, made from narrower fibers of polyphenylene benzobisthiazole (PBZT) and carbon nanotubes. These highly aligned nanocomposite fibers could exploit the high thermal conductivities of carbon nanotubes for thermal-management applications. In the flash diffusivity technique as practiced heretofore, one or more heat pulse(s) is (are) applied to the front face of a plate or disk material specimen and the resulting time-varying temperature on the rear face is measured. Usually, the heat pulse is generated by use of a xenon flash lamp, and the variation of temperature on the rear face is measured by use of an infrared detector. The flash energy is made large enough to produce a usefully high temperature rise on the rear face, but not so large as to significantly alter the specimen material. Once the measurement has been completed, the thermal diffusivity of the specimen is computed from the thickness of the specimen and the time dependence of the temperature variation on the rear face. Heretofore, the infrared detector used in the flash diffusivity technique has been a single-point detector, which responds to a spatial average of the thermal radiation from the rear specimen surface. Such a detector cannot distinguish among regions of differing diffusivity within the specimen. Moreover, two basic assumptions of the thermaldiffusivity technique as practiced heretofore are that the specimen is homogeneous and that heat flows one-dimensionally from the front to the rear face. These assumptions are not valid for an inhomogeneous (composite) material.

  19. Quantitative nondestructive evaluation of materials and structures

    NASA Technical Reports Server (NTRS)

    Smith, Barry T.

    1991-01-01

    An experimental investigation was undertaken to quantify damage tolerance and resistance in composite materials impacted using the drop-weight method. Tests were conducted on laminates of several different carbon-fiber composite systems, such as epoxies, modified epoxies, and amorphous and semicrystalline thermoplastics. Impacted composite specimens were examined using destructive and non-destructive techniques to establish the characteristic damage states. Specifically, optical microscopy, ultrasonic, and scanning electron microscopy techniques were used to identify impact induced damage mechanisms. Damage propagation during post impact compression was also studied.

  20. Reliability of void detection in structural ceramics using scanning laser acoustic microscopy

    NASA Technical Reports Server (NTRS)

    Roth, D. J.; Klima, S. J.; Kiser, J. D.; Baaklini, G. Y.

    1985-01-01

    The reliability of scanning laser acoustic microscopy (SLAM) for detecting surface voids in structural ceramic test specimens was statistically evaluated. Specimens of sintered silicon nitride and sintered silicon carbide, seeded with surface voids, were examined by SLAM at an ultrasonic frequency of 100 MHz in the as fired condition and after surface polishing. It was observed that polishing substantially increased void detectability. Voids as small as 100 micrometers in diameter were detected in polished specimens with 0.90 probability at a 0.95 confidence level. In addition, inspection times were reduced up to a factor of 10 after polishing. The applicability of the SLAM technique for detection of naturally occurring flaws of similar dimensions to the seeded voids is discussed. A FORTRAN program listing is given for calculating and plotting flaw detection statistics.

  1. Laboratory Reproduction and Failure Analysis of Cracked Orbiter Reaction Control System Niobium Thruster Injectors

    NASA Technical Reports Server (NTRS)

    Jacobs, Jeremy B.; Castner, Willard L.

    2007-01-01

    A viewgraph presentation describing cracks and failure analysis of an orbiter reaction control system is shown. The topics include: 1) Endeavour STS-113 Landing; 2) RCS Thruster; 3) Thruster Cross-Section; 4) RCS Injector; 5) RCS Thruster, S/N 120l 6) Counterbore Cracks; 7) Relief Radius Cracks; 8) RCS Thruster Cracking History; 9) Thruster Manufacturing Timelines; 10) Laboratory Reproduction of Injector Cracking; 11) The Brownfield Specimen; 12) HF EtchantTests/Specimen Loading; 13) Specimen #3 HF + 600F; 14) Specimen #3 IG Fracture; 15) Specimen #5 HF + 600F; 16) Specimen #5 Popcorn ; 17) Specimen #5 Cleaned and Bent; 18) HF Exposure Test Matrix; 19) Krytox143AC Tests; 20) KrytoxTests/Specimen Loading; 21) Specimen #13 Krytox + 600F; and 22) KrytoxExposure Test Matrix.

  2. Anaerobic Bacteria in Clinical Specimens - Frequent, But a Neglected Lot: A Five Year Experience at a Tertiary Care Hospital.

    PubMed

    Shenoy, Padmaja Ananth; Vishwanath, Shashidhar; Gawda, Ashwini; Shetty, Seema; Anegundi, Renuka; Varma, Muralidhar; Mukhopadhyay, Chiranjay; Chawla, Kiran

    2017-07-01

    Anaerobic bacteria which constitute a significant proportion of the normal microbiota also cause variety of infections involving various anatomic sites. Considering the tedious culture techniques with longer turnaround time, anaerobic cultures are usually neglected by clinicians and microbiologists. To study the frequency of isolation of different anaerobic bacteria from various clinical specimens. A retrospective study to analyse the frequency of isolation of different anaerobic bacteria, was conducted over a period of five years from 2011 to 2015 including various clinical specimens submitted to anaerobic division of Microbiology laboratory. Anaerobic bacteria were isolated and identified following standard bacteriological techniques. Pathogenic anaerobes (n=336) were isolated from 278 (12.48%) of overall 2227 specimens processed with an average yield of 1.2 isolates. Anaerobes were isolated as polymicrobial flora with or without aerobic bacterial pathogens in 159 (57.2%) patients. Anaerobic Gram-negative bacilli (140, 41.7%) were the predominant isolates. B. fragilis group (67, 19.9%) were the most commonly isolated anaerobic pathogens. Anaerobes were predominantly isolated from deep seated abscess (23.9%). Pathogenic anaerobes were isolated from various infection sites. Unless culture and susceptibility tests are performed as a routine, true magnitude of antimicrobial resistance among anaerobic pathogens will not be known. Knowledge of the distribution of these organisms may assist in the selection of appropriate empirical therapy for anaerobic infections.

  3. Modal parameter identification using the log decrement method and band-pass filters

    NASA Astrophysics Data System (ADS)

    Liao, Yabin; Wells, Valana

    2011-10-01

    This paper presents a time-domain technique for identifying modal parameters of test specimens based on the log-decrement method. For lightly damped multidegree-of-freedom or continuous systems, the conventional method is usually restricted to identification of fundamental-mode parameters only. Implementation of band-pass filters makes it possible for the proposed technique to extract modal information of higher modes. The method has been applied to a polymethyl methacrylate (PMMA) beam for complex modulus identification in the frequency range 10-1100 Hz. Results compare well with those obtained using the Least Squares method, and with those previously published in literature. Then the accuracy of the proposed method has been further verified by experiments performed on a QuietSteel specimen with very low damping. The method is simple and fast. It can be used for a quick estimation of the modal parameters, or as a complementary approach for validation purposes.

  4. Development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements

    NASA Technical Reports Server (NTRS)

    Rey, Charles A.

    1991-01-01

    The development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements are discussed. Efforts were directed towards the following task areas: design and development of a High Temperature Acoustic Levitator (HAL) for containerless processing and property measurements at high temperatures; testing of the HAL module to establish this technology for use as a positioning device for microgravity uses; construction and evaluation of a brassboard hot wall Acoustic Levitation Furnace; construction and evaluation of a noncontact temperature measurement (NCTM) system based on AGEMA thermal imaging camera; construction of a prototype Division of Amplitude Polarimetric Pyrometer for NCTM of levitated specimens; evaluation of and recommendations for techniques to control contamination in containerless materials processing chambers; and evaluation of techniques for heating specimens to high temperatures for containerless materials experimentation.

  5. Development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements

    NASA Astrophysics Data System (ADS)

    Rey, Charles A.

    1991-03-01

    The development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements are discussed. Efforts were directed towards the following task areas: design and development of a High Temperature Acoustic Levitator (HAL) for containerless processing and property measurements at high temperatures; testing of the HAL module to establish this technology for use as a positioning device for microgravity uses; construction and evaluation of a brassboard hot wall Acoustic Levitation Furnace; construction and evaluation of a noncontact temperature measurement (NCTM) system based on AGEMA thermal imaging camera; construction of a prototype Division of Amplitude Polarimetric Pyrometer for NCTM of levitated specimens; evaluation of and recommendations for techniques to control contamination in containerless materials processing chambers; and evaluation of techniques for heating specimens to high temperatures for containerless materials experimentation.

  6. Is laser conditioning a valid alternative to conventional etching for aesthetic brackets?

    PubMed

    Sfondrini, M F; Calderoni, G; Vitale, M C; Gandini, P; Scribante, A

    2018-03-01

    ER:Yag lasers have been described as a more conservative alternative to conventional acid-etching enamel conditioning technique, when bonding conventional metallic orthodontic brackets. Since the use of aesthetic orthodontic brackets is constantly increasing, the purpose of the present report has been to test laser conditioning with different aesthetic brackets. Study Design: Five different aesthetic brackets (microfilled copolymer, glass fiber, sapphire, polyoxymethylene and sintered ceramic) were tested for shear bond strength and Adhesive Remnant Index scores using two different enamel conditioning techniques (acid etching and ER:Yag laser application). Two hundred bovine incisors were extracted, cleaned and embedded in resin. Specimens were then divided into 10 groups with random tables. Half of the specimens were conditioned with conventional orthophosphoric acid gel, the other half with ER:Yag laser. Different aesthetic brackets (microfilled copolymer, glass fiber, sapphire, polyoxymethylene and sintered ceramic) were then bonded to the teeth. Subsequently all groups were tested in shear mode with a Universal Testing Machine. Shear bond strength values and adhesive remnant index scores were recorded. Statistical analysis was performed. When considering conventional acid etching technique, sapphire, polyoxymethylene and sintered ceramic brackets exhibited the highest SBS values. Lowest values were reported for microfilled copolymer and glass fiber appliances. A significant decrease in SBS values after laser conditioning was reported for sapphire, polyoxymethylene and sintered ceramic brackets, whereas no significant difference was reported for microfilled copolymer and glass fiber brackets. Significant differences in ARI scores were also reported. Laser etching can significantly reduce bonding efficacy of sapphire, polyoxymethylene and sintered ceramic brackets.

  7. Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques.

    PubMed

    Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T

    2016-08-01

    Currently no data comparing the denture base adaptation of CAD-CAM and conventional denture processing techniques have been reported. The purpose of this in vitro study was to compare the denture base adaptation of pack and press, pour, injection, and CAD-CAM techniques for fabricating dentures to determine which process produces the most accurate and reproducible adaptation. A definitive cast was duplicated to create 40 gypsum casts that were laser scanned before any fabrication procedures were initiated. A master denture was made using the CAD-CAM process and was then used to create a putty mold for the fabrication of 30 standardized wax festooned dentures, 10 for each of the conventional processing techniques (pack and press, pour, injection). Scan files from 10 casts were sent to Global Dental Science, LLC for fabrication of the CAD-CAM test specimens. After specimens for each of the 4 techniques had been fabricated, they were hydrated for 24 hours and the intaglio surface laser scanned. The scan file of each denture was superimposed on the scan file of the corresponding preprocessing cast using surface matching software. Measurements were made at 60 locations, providing evaluation of fit discrepancies at the following areas: apex of the denture border, 6 mm from the denture border, crest of the ridge, palate, and posterior palatal seal. The use of median and interquartile range was used to assess accuracy and reproducibility. The Levine and Kruskal-Wallis analysis of variance was used to evaluate differences between processing techniques at the 5 specified locations (α=.05). The ranking of results based on median and interquartile range determined that the accuracy and reproducibility of the CAD-CAM technique was more consistently localized around zero at 3 of the 5 locations. Therefore, the CAD-CAM technique showed the best combination of accuracy and reproducibility among the tested fabrication techniques. The pack and press technique was more accurate at 2 of the 5 locations; however, its interquartile range (reproducibility) was the greatest of the 4 tested processing techniques. The pour technique was the most reproducible at 2 of the 5 locations; however, its accuracy was the lowest of the tested techniques. The CAD-CAM fabrication process was the most accurate and reproducible denture fabrication technique when compared with pack and press, pour, and injection denture base processing techniques. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. Determination of Residual Stresses in Rails

    DOT National Transportation Integrated Search

    1983-05-01

    A destructive sectioning technique for measuring the complete three-dimensional residual stresses in a rail cross section was developed. The technique was applied to four tangent rail specimens: two 136-pound specimens were taken from FAST (Facility ...

  9. Diagnosis of Helicobacter pylori infection: Current options and developments

    PubMed Central

    Wang, Yao-Kuang; Kuo, Fu-Chen; Liu, Chung-Jung; Wu, Meng-Chieh; Shih, Hsiang-Yao; Wang, Sophie SW; Wu, Jeng-Yih; Kuo, Chao-Hung; Huang, Yao-Kang; Wu, Deng-Chyang

    2015-01-01

    Accurate diagnosis of Helicobacter pylori (H. pylori) infection is a crucial part in the effective management of many gastroduodenal diseases. Several invasive and non-invasive diagnostic tests are available for the detection of H. pylori and each test has its usefulness and limitations in different clinical situations. Although none can be considered as a single gold standard in clinical practice, several techniques have been developed to give the more reliable results. Invasive tests are performed via endoscopic biopsy specimens and these tests include histology, culture, rapid urease test as well as molecular methods. Developments of endoscopic equipment also contribute to the real-time diagnosis of H. pylori during endoscopy. Urea breathing test and stool antigen test are most widely used non-invasive tests, whereas serology is useful in screening and epidemiological studies. Molecular methods have been used in variable specimens other than gastric mucosa. More than detection of H. pylori infection, several tests are introduced into the evaluation of virulence factors and antibiotic sensitivity of H. pylori, as well as screening precancerous lesions and gastric cancer. The aim of this article is to review the current options and novel developments of diagnostic tests and their applications in different clinical conditions or for specific purposes. PMID:26523098

  10. Results of using frequency banded SAFT for examining three types of defects

    NASA Astrophysics Data System (ADS)

    Clayton, Dwight; Barker, Alan; Santos-Villalobos, Hector

    2017-02-01

    A multitude of concrete-based structures are typically part of a light water reactor (LWR) plant to provide the foundation, support, shielding, and containment functions. Concrete has been used in the construction of nuclear power plants (NPPs) because of three primary properties; its low cost, structural strength, and ability to shield radiation. Examples of concrete structures important to the safety of LWR plants include the containment building, spent fuel pool, and cooling towers. This use has made concrete's long-term performance crucial for the safe operation of commercial NPPs. Extending reactor life to 60 years and beyond will likely increase susceptibility and severity of known forms of degradation. Additionally, new mechanisms of materials degradation are also possible. Specially designed and fabricated test specimens can provide realistic flaws that are similar to actual flaws in terms of how they interact with a particular Nondestructive Evaluation (NDE) technique. Artificial test blocks allow the isolation of certain testing problems as well as the variation of certain parameters. Because conditions in the laboratory are controlled, the number of unknown variables can be decreased, making it possible to focus on specific aspects, investigate them in detail, and gain further information on the capabilities and limitations of each method. To minimize artifacts caused by boundary effects, the dimensions of the specimens should not be too compact. In this paper, we apply the frequency banded Synthetic Aperture Focusing Technique (SAFT) technique to a 2.134 m × 2.134 m × 1.016 m concrete test specimen with twenty deliberately embedded defects. These twenty embedded defects simulate voids (honeycombs), delamination, and embedded organic construction debris. Using the time-frequency technique of wavelet packet decomposition and reconstruction, the spectral content of the signal can be divided into two resulting child nodes. The resulting two nodes can then also be divided into two child nodes with each child node containing half of the bandwidth (spectral content) of its parent node. This process can be repeated until the bandwidth of the child nodes is sufficiently small. Once the desired bandwidth has been obtained, the band limited signal can be analyzed using SAFT, enabling the visualization of reflectivity of a frequency band and that band's interaction with the contents of the concrete structure. This paper examines the benefits of using frequency banded SAFT.

  11. Gamma radiation effects on the dynamic fatigue measurements of glass discs

    NASA Technical Reports Server (NTRS)

    Ananaba, T. O. J.; Kinser, D. L.

    1985-01-01

    Circular specimens of low iron soda lime silicate glass were blasted with grit after having a circular notch etched into their centers. After separation into two groups, one group was exposed to gamma radiation. The fracture strengths of all samples were then tested by the biaxial technique, i.e., specimens were balanced on three balls and loaded in the center by a piston. The irradiated samples had received a 140,000 Gy dose from a Co-60 source. An enhanced interaction between the ambient moisture and the grit-blasted central notch was observed in the irradiated samples, which displayed accelerated corrosion.

  12. Laser Peening and Shot Peening Effects on Fatigue Life and Surface Roughness of Friction Stir Welded 7075-T7351 Aluminum

    NASA Technical Reports Server (NTRS)

    Hatamleh, Omar; Lyons, Jed; Forman, Royce

    2006-01-01

    The effects of laser peening, shot peening, and a combination of both on the fatigue life of Friction Stir Welds (FSW) was investigated. The fatigue samples consisted of dog bone specimens and the loading was applied in a direction perpendicular to the weld direction. Several laser peening conditions with different intensities, durations, and peening order were tested to obtain the optimum peening parameters. The surface roughness resulting from various peening techniques was assessed and characterized. The results indicate a significant increase in fatigue life using laser peening compared to shot peened versus their native welded specimens.

  13. Halogen occultation experiment (HALOE) optical witness-plate program

    NASA Technical Reports Server (NTRS)

    Harvey, Gale A.; Raper, James L.

    1989-01-01

    An optical witness plate program was implemented to monitor buildup of molecular contamination in the clean room during the assembly and testing of the Halogen Occulation Experiment (HALOE) instrument. Travel plates to monitor molecular contamination when the instrument is not in the clean room are also measured. The instrument technique is high-resolution transmission spectroscopy in the 3 micron spectral region using a Fourier transform spectrometer. Witness specimens of low index of refraction, infrared transmitting material are used for contaminant monitoring and for spectral signature analysis. Spectral signatures of possible molecular contamination are presented. No condensible volatile material contamination of HALOE optical witness specimens have yet been found.

  14. Comparison of nerve trimming with the Er:YAG laser and steel knife

    NASA Astrophysics Data System (ADS)

    Josephson, G. D.; Bass, Lawrence S.; Kasabian, A. K.

    1995-05-01

    Best outcome in nerve repair requires precise alignment and minimization of scar at the repair interface. Surgeons attempt to create the sharpest cut surface at the nerve edge prior to approximation. Pulsed laser modalities are being investigated in several medical applications which require precise atraumatic cutting. We compared nerve trimming with the Er:YAG laser (1375 J/cm2) to conventional steel knife trimming prior to neurorrhaphy. Sprague- Dawley rats were anesthetized with ketamine and xylazine. Under operating microscope magnification the sciatic nerve was dissected and transected using one of the test techniques. In the laser group, the pulses were directed axially across the nerve using a stage which fixed laser fiber/nerve distance and orientation. Specimens were sent for scanning electron microscopy (SEM) at time zero. Epineurial repairs were performed with 10 - 0 nylon simple interrupted sutures. At intervals to 90 days, specimens were harvested and sectioned longitudinally and axially for histologic examination. Time zero SEM revealed clean cuts in both groups but individual axons were clearly visible in all laser specimens. Small pits were also visible on the cut surface of laser treated nerves. No significant differences in nerve morphology were seen during healing. Further studies to quantify axon counts, and functional outcome will be needed to assess this technique of nerve trimming. Delivery system improvements will also be required, to make the technique clinically practical.

  15. Thermomechanical testing of high-temperature composites - Thermomechanical fatigue (TMF) behavior of SiC(SCS-6)/Ti-15-3

    NASA Technical Reports Server (NTRS)

    Castelli, Michael G.; Bartolotta, Paul; Ellis, John R.

    1992-01-01

    Thermomechanical testing techniques recently developed for monolithic structural alloys were successfully extended to continuous fiber reinforced composite materials in plate form. The success of this adaptation was verified on a model metal matrix composite (MMC) material, namely SiC(SCS-6)/Ti-15V-3Cr-3Al-3Sn. Effects of heating system type and specimen preparation are also addressed. Cyclic lives determined under full thermomechanical conditions were shown to be significantly reduced from those obtained under comparable isothermal and in-phase bi-thermal conditions. Fractography and metallography from specimens subjected to isothermal, out-of-phase and in-phase conditions reveal distinct differences in damage-failure modes. Isothermal metallography revealed extensive matrix cracking associated with fiber damage throughout the entire cross-section of the specimen. Out-of-phase metallography revealed extensive matrix damage associated with minimal (if any) fiber cracking. However, the damage was located exclusively at surface and near-surface locations. In-phase conditions produced extensive fiber cracking throughout the entire cross-section, associated with minimal (if any) matrix damage.

  16. DNA Extraction Method Affects the Detection of a Fungal Pathogen in Formalin-Fixed Specimens Using qPCR.

    PubMed

    Adams, Andrea J; LaBonte, John P; Ball, Morgan L; Richards-Hrdlicka, Kathryn L; Toothman, Mary H; Briggs, Cheryl J

    2015-01-01

    Museum collections provide indispensable repositories for obtaining information about the historical presence of disease in wildlife populations. The pathogenic amphibian chytrid fungus Batrachochytrium dendrobatidis (Bd) has played a significant role in global amphibian declines, and examining preserved specimens for Bd can improve our understanding of its emergence and spread. Quantitative PCR (qPCR) enables Bd detection with minimal disturbance to amphibian skin and is significantly more sensitive to detecting Bd than histology; therefore, developing effective qPCR methodologies for detecting Bd DNA in formalin-fixed specimens can provide an efficient and effective approach to examining historical Bd emergence and prevalence. Techniques for detecting Bd in museum specimens have not been evaluated for their effectiveness in control specimens that mimic the conditions of animals most likely to be encountered in museums, including those with low pathogen loads. We used American bullfrogs (Lithobates catesbeianus) of known infection status to evaluate the success of qPCR to detect Bd in formalin-fixed specimens after three years of ethanol storage. Our objectives were to compare the most commonly used DNA extraction method for Bd (PrepMan, PM) to Macherey-Nagel DNA FFPE (MN), test optimizations for Bd detection with PM, and provide recommendations for maximizing Bd detection. We found that successful detection is relatively high (80-90%) when Bd loads before formalin fixation are high, regardless of the extraction method used; however, at lower infection levels, detection probabilities were significantly reduced. The MN DNA extraction method increased Bd detection by as much as 50% at moderate infection levels. Our results indicate that, for animals characterized by lower pathogen loads (i.e., those most commonly encountered in museum collections), current methods may underestimate the proportion of Bd-infected amphibians. Those extracting DNA from archived museum specimens should ensure that the techniques they are using are known to provide high-quality throughput DNA for later analysis.

  17. Surface analysis of space telescope material specimens

    NASA Technical Reports Server (NTRS)

    Fromhold, A. T.; Daneshvar, K.

    1985-01-01

    Qualitative and quantitative data on Space Telescope materials which were exposed to low Earth orbital atomic oxygen in a controlled experiment during the 41-G (STS-17) mission were obtained utilizing the experimental techniques of Rutherford backscattering (RBS), particle induced X-ray emission (PIXE), and ellipsometry (ELL). The techniques employed were chosen with a view towards appropriateness for the sample in question, after consultation with NASA scientific personnel who provided the material specimens. A group of eight samples and their controls selected by NASA scientists were measured before and after flight. Information reported herein include specimen surface characterization by ellipsometry techniques, a determination of the thickness of the evaporated metal specimens by RBS, and a determination of trace impurity species present on and within the surface by PIXE.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Song, Bo; Nelson, Kevin; Lipinski, Ronald J.

    Iridium alloys have superior strength and ductility at elevated temperatures, making them useful as structural materials for certain high-temperature applications. However, experimental data on their high-temperature high-strain-rate performance are needed for understanding high-speed impacts in severe elevated-temperature environments. Kolsky bars (also called split Hopkinson bars) have been extensively employed for high-strain-rate characterization of materials at room temperature, but it has been challenging to adapt them for the measurement of dynamic properties at high temperatures. Current high-temperature Kolsky compression bar techniques are not capable of obtaining satisfactory high-temperature high-strain-rate stress-strain response of thin iridium specimens investigated in this study. We analyzedmore » the difficulties encountered in high-temperature Kolsky compression bar testing of thin iridium alloy specimens. Appropriate modifications were made to the current high-temperature Kolsky compression bar technique to obtain reliable compressive stress-strain response of an iridium alloy at high strain rates (300 – 10000 s -1) and temperatures (750°C and 1030°C). Uncertainties in such high-temperature high-strain-rate experiments on thin iridium specimens were also analyzed. The compressive stress-strain response of the iridium alloy showed significant sensitivity to strain rate and temperature.« less

  19. Detection, Mapping, and Quantification of Single Walled Carbon Nanotubes in Histological Specimens with Photoacoustic Microscopy

    PubMed Central

    Mikos, Antonios G.; Jansen, John A.; Shroyer, Kenneth R.; Wang, Lihong V.; Sitharaman, Balaji

    2012-01-01

    Aims In the present study, the efficacy of multi-scale photoacoustic microscopy (PAM) was investigated to detect, map, and quantify trace amounts [nanograms (ng) to micrograms (µg)] of SWCNTs in a variety of histological tissue specimens consisting of cancer and benign tissue biopsies (histological specimens from implanted tissue engineering scaffolds). Materials and Methods Optical-resolution (OR) and acoustic-resolution (AR) - Photoacoustic microscopy (PAM) was employed to detect, map and quantify the SWCNTs in a variety of tissue histological specimens and compared with other optical techniques (bright-field optical microscopy, Raman microscopy, near infrared (NIR) fluorescence microscopy). Results Both optical-resolution and acoustic-resolution PAM, allow the detection and quantification of SWCNTs in histological specimens with scalable spatial resolution and depth penetration. The noise-equivalent detection sensitivity to SWCNTs in the specimens was calculated to be as low as ∼7 pg. Image processing analysis further allowed the mapping, distribution, and quantification of the SWCNTs in the histological sections. Conclusions The results demonstrate the potential of PAM as a promising imaging technique to detect, map, and quantify SWCNTs in histological specimens, and could complement the capabilities of current optical and electron microscopy techniques in the analysis of histological specimens containing SWCNTs. PMID:22496892

  20. Animation of in vitro biomechanical tests.

    PubMed

    Cripton, P A; Sati, M; Orr, T E; Bourquin, Y; Dumas, G A; Nolte, L P

    2001-08-01

    Interdisciplinary communication of three-dimensional kinematic data arising from in vitro biomechanical tests is challenging. Complex kinematic representations such as the helical axes of motion (HAM) add to the challenge. The difficulty increases further when other quantities (i.e. load or tissue strain data) are combined with the kinematic data. The objectives of this study were to develop a method to graphically replay and animate in vitro biomechanical tests including HAM data. This will allow intuitive interpretation of kinematic and other data independent of the viewer's area of expertise. The value of this method was verified with a biomechanical test investigating load-sharing of the cervical spine. Three 3.0 mm aluminium spheres were glued to each of the two vertebrae from a C2-3 segment of a human cervical spine. Before the biomechanical tests, CT scans were made of the specimen (slice thickness=1.0 mm and slice spacing=1.5 mm). The specimens were subjected to right axial torsion moments (2.0 Nm). Strain rosettes mounted to the anterior surface of the C3 vertebral body and bilaterally beneath the facet joints on C3 were used to estimate the force flow through the specimen. The locations of the aluminium spheres were digitised using a space pointer and the motion analysis system. Kinematics were measured using an optoelectronic motion analysis system. HAMs were calculated to describe the specimen kinematics. The digitised aluminium sphere locations were used to match the CT and biomechanical test data (RMS errors between the CT and experimental points were less than 1.0 mm). The biomechanical tests were "replayed" by animating reconstructed CT models in accordance with the recorded experimental kinematics, using custom software. The animated test replays allowed intuitive analysis of the kinematic data in relation to the strain data. This technique improves the ability of experts from disparate backgrounds to interpret and discuss this type of biomechanical data.

  1. A new laser reflectance system capable of measuring changing cross-sectional area of soft tissues during tensile testing.

    PubMed

    Pokhai, Gabriel G; Oliver, Michele L; Gordon, Karen D

    2009-09-01

    Determination of the biomechanical properties of soft tissues such as tendons and ligaments is dependent on the accurate measurement of their cross-sectional area (CSA). Measurement methods, which involve contact with the specimen, are problematic because soft tissues are easily deformed. Noncontact measurement methods are preferable in this regard, but may experience difficulty in dealing with the complex cross-sectional shapes and glistening surfaces seen in soft tissues. Additionally, existing CSA measurement systems are separated from the materials testing machine, resulting in the inability to measure CSA during testing. Furthermore, CSA measurements are usually made in a different orientation, and with a different preload, prior to testing. To overcome these problems, a noncontact laser reflectance system (LRS) was developed. Designed to fit in an Instron 8872 servohydraulic test machine, the system measures CSA by orbiting a laser transducer in a circular path around a soft tissue specimen held by tissue clamps. CSA measurements can be conducted before and during tensile testing. The system was validated using machined metallic specimens of various shapes and sizes, as well as different sizes of bovine tendons. The metallic specimens could be measured to within 4% accuracy, and the tendons to within an average error of 4.3%. Statistical analyses showed no significant differences between the measurements of the LRS and those of the casting method, an established measurement technique. The LRS was successfully used to measure the changing CSA of bovine tendons during uniaxial tensile testing. The LRS developed in this work represents a simple, quick, and accurate way of reconstructing complex cross-sectional profiles and calculating cross-sectional areas. In addition, the LRS represents the first system capable of automatically measuring changing CSA of soft tissues during tensile testing, facilitating the calculation of more accurate biomechanical properties.

  2. The suitability of small biopsy and cytology specimens for EGFR and other mutation testing in non-small cell lung cancer

    PubMed Central

    Wang, Shu; Yu, Bing; Ng, Chiu Chin; Mercorella, Belinda; Selinger, Christina I.; O’Toole, Sandra A.

    2015-01-01

    Background Patients with advanced non-small cell lung cancer (NSCLC) benefit from treatment with epidermal growth factor receptor (EGFR) tyrosine kinase inhibitors (TKIs) when their tumor harbors an activating EGFR mutation. As the majority of NSCLC patients present with advanced disease, cytology and small biopsy specimens are frequently the only tissue available for mutation testing, but can pose challenges due to low tumor content. We aim to better define the suitability of these specimens for mutation testing. Methods NSCLC cases referred to our institution for mutation testing over a 15-month period were retrospectively reviewed. Specimens were tested for mutations including EGFR, KRAS, and BRAF, using a multiplex PCR assay (OncoCarta Panel v1.0) and analyzed on the Agena Bioscience MassARRAY platform. Results A total of 146 specimens were tested, comprising 53 (36.3%) resection specimens (including 28 lung resection specimens), 55 (37.7%) small biopsy specimens and 38 (26%) cytology specimens. Of 142 cases with sufficient DNA for mutation testing, EGFR mutations were detected in 31 specimens (21.8%), KRAS mutations in 31 specimens (21.8%) and BRAF mutations in three specimens (2.1%). There was no significant difference in the EGFR mutation rate between lung resection (10 of 28 cases; 35.7%), small biopsy (9 of 53 cases; 17%), and cytology specimens (8 of 36 cases; 22.2%). Conclusions Our results support the utility of small biopsy and cytology specimens for mutation testing. Careful evaluation of the adequacy of small specimens is required to minimize the risk of false negative or positive results. PMID:25870794

  3. Finite element analysis of steel fiber-reinforced concrete (SFRC): validation of experimental tensile capacity of dog-bone specimens

    NASA Astrophysics Data System (ADS)

    Islam, Md. Mashfiqul; Chowdhury, Md. Arman; Sayeed, Md. Abu; Hossain, Elsha Al; Ahmed, Sheikh Saleh; Siddique, Ashfia

    2014-09-01

    Finite element analyses are conducted to model the tensile capacity of steel fiber-reinforced concrete (SFRC). For this purpose dog-bone specimens are casted and tested under direct and uniaxial tension. Two types of aggregates (brick and stone) are used to cast the SFRC and plain concrete. The fiber volume ratio is maintained 1.5 %. Total 8 numbers of dog-bone specimens are made and tested in a 1000-kN capacity digital universal testing machine (UTM). The strain data are gathered employing digital image correlation technique from high-definition images and high-speed video clips. Then, the strain data are synthesized with the load data obtained from the load cell of the UTM. The tensile capacity enhancement is found 182-253 % compared to control specimen to brick SFRC and in case of stone SFRC the enhancement is 157-268 %. Fibers are found to enhance the tensile capacity as well as ductile properties of concrete that ensures to prevent sudden brittle failure. The dog-bone specimens are modeled in the ANSYS 10.0 finite element platform and analyzed to model the tensile capacity of brick and stone SFRC. The SOLID65 element is used to model the SFRC as well as plain concretes by optimizing the Poisson's ratio, modulus of elasticity, tensile strength and stress-strain relationships and also failure pattern as well as failure locations. This research provides information of the tensile capacity enhancement of SFRC made of both brick and stone which will be helpful for the construction industry of Bangladesh to introduce this engineering material in earthquake design. Last of all, the finite element outputs are found to hold good agreement with the experimental tensile capacity which validates the FE modeling.

  4. Techniques for Reducing Thermal Contact Resistance in Steady-State Thermal Conductivity Measurements on Polymer Composites

    NASA Astrophysics Data System (ADS)

    Stacey, C.; Simpkin, A. J.; Jarrett, R. N.

    2016-11-01

    The National Physical Laboratory (NPL) has developed a new variation on the established guarded hot plate technique for steady-state measurements of thermal conductivity. This new guarded hot plate has been specifically designed for making measurements on specimens with a thickness that is practical for advanced industrial composite materials and applications. During the development of this new guarded hot plate, NPL carried out an experimental investigation into methods for minimising the thermal contact resistance between the test specimen and the plates of the apparatus. This experimental investigation included tests on different thermal interface materials for use in another NPL facility based on a commercial guarded heat flow meter apparatus conforming to standard ASTM E1530-11. The results show the effect of applying different quantities of the type of heat transfer compound suggested in ASTM E1530-11 (clause 10.7.3) and also the effect on thermal resistance of alternative types of thermal interface products. The optimum quantities of two silicone greases were determined, and a silicone grease filled with copper was found to offer the best combination of repeatability, small hysteresis effect and a low thermal contact resistance. However, two products based on a textured indium foil and pyrolytic graphite sheet were found to offer similar or better reductions in thermal contact resistance, but with quicker, easier application and the advantages of protecting the apparatus plates from damage and being useable with specimen materials that would otherwise absorb silicone grease.

  5. Laser thermal shock and fatigue testing system

    NASA Astrophysics Data System (ADS)

    Fantini, Vincenzo; Serri, Laura; Bianchi, P.

    1997-08-01

    Thermal fatigue consists in repeatedly cycling the temperature of a specimen under test without any other constraint and stopping the test when predefined damage aspects. The result is a lifetime in terms of number of cycles. The parameters of the thermal cycle are the following: minimum and maximum temperature, time of heating, of cooling and time at high or at low temperature. When the temperature jump is very big and fast, phenomena of thermal shock can be induced. Among the numerous techniques used to perform these tests, the laser thermal fatigue cycling is very effective when fast heating of small and localized zones is required. That's the case of test performed to compare new and repaired blades of turbogas machines or components of combustion chambers of energy power plants. In order to perform these tests a thermal fatigue system, based on 1 kW Nd-YAG laser as source of heating, has been developed. The diameter of the heated zone of the specimen irradiated by the laser is in the range 0.5 - 20 mm. The temperatures can be chosen between 200 degree(s)C and 1500 degree(s)C and the piece can be maintained at high and/or low temperature from 0 s to 300 s. Temperature are measured by two sensors: a pyrometer for the high range (550 - 1500 degree(s)C) and a contactless thermocouple for the low range (200 - 550 degree(s)C). Two different gases can be blown on the specimen in the irradiated spot or in sample backside to speed up cooling phase. A PC-based control unit with a specially developed software performs PID control of the temperature cycle by fast laser power modulation. A high resolution vision system of suitable magnification is connected to the control unit to detect surface damages on the specimen, allowing real time monitoring of the tested zone as well as recording and reviewing the images of the sample during the test. Preliminary thermal fatigue tests on flat specimens of INCONEL 738 and HAYNES 230 are presented. IN738 samples, laser cladded by powder of the same material to simulate the refurbishing of a damaged turbine blade after long-term operation, are compared to the parents. Lifetimes are decreasing when high temperature of the cycle is increased and shorter lifetimes of repaired pieces have been found. Laser and TIG welding on HY230 specimens are compared to the parent. Parent and repaired samples have no evidence of cracks after 1500 thermal cycles between 650 and 1000 degree(s)C.

  6. Modeling and Characterization of Dynamic Failure of Soda-lime Glass Under High Speed Impact

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Wenning N.; Sun, Xin; Chen, Weinong W.

    2012-05-27

    In this paper, the impact-induced dynamic failure of a soda-lime glass block is studied using an integrated experimental/analytical approach. The Split Hopkinson Pressure Bar (SHPB) technique is used to conduct dynamic failure test of soda-lime glass first. The damage growth patterns and stress histories are reported for various glass specimen designs. Making use of a continuum damage mechanics (CDM)-based constitutive model, the initial failure and subsequent stiffness reduction of glass are simulated and investigated. Explicit finite element analyses are used to simulate the glass specimen impact event. A maximum shear stress-based damage evolution law is used in describing the glassmore » damage process under combined compression/shear loading. The impact test results are used to quantify the critical shear stress for the soda-lime glass under examination.« less

  7. Signal processing methods for in-situ creep specimen monitoring

    NASA Astrophysics Data System (ADS)

    Guers, Manton J.; Tittmann, Bernhard R.

    2018-04-01

    Previous work investigated using guided waves for monitoring creep deformation during accelerated life testing. The basic objective was to relate observed changes in the time-of-flight to changes in the environmental temperature and specimen gage length. The work presented in this paper investigated several signal processing strategies for possible application in the in-situ monitoring system. Signal processing methods for both group velocity (wave-packet envelope) and phase velocity (peak tracking) time-of-flight were considered. Although the Analytic Envelope found via the Hilbert transform is commonly applied for group velocity measurements, erratic behavior in the indicated time-of-flight was observed when this technique was applied to the in-situ data. The peak tracking strategies tested had generally linear trends, and tracking local minima in the raw waveform ultimately showed the most consistent results.

  8. Materials screening chamber for testing materials resistance to atomic oxygen

    NASA Technical Reports Server (NTRS)

    Pippin, H. G.; Carruth, Ralph

    1989-01-01

    A unique test chamber for exposing material to a known flux of oxygen atoms is described. The capabilities and operating parameters of the apparatus include production of an oxygen atom flux in excess of 5 x 10 to the 16th atoms/sq cm-sec, controlled heating of the sample specimen, RF circuitry to contain the plasma within a small volume, and long exposure times. Flux measurement capabilities include a calorimetric probe and a light titration system. Accuracy and limitations of these techniques are discussed. An extension to the main chamber to allow simultaneous ultraviolet and atomic oxygen exposure is discussed. The oxygen atoms produced are at thermal energies. Sample specimens are maintained at any selected temperature between ambient and 200 C, to within + or - 2 C. A representative example of measurements made using the chamber is presented.

  9. Modified rapid immunohistochemical staining for intraoperative diagnosis of malignant brain tumors.

    PubMed

    Suzuki, Akane; Maruyama, Takashi; Nitta, Masayuki; Komori, Takashi; Ikuta, Soko; Kawamata, Takakazu; Muragaki, Yoshihiro

    2017-10-01

    Rapid immunohistochemistry (R-IHC) has been developing mainly as a support technique in the rapid diagnosis of central nervous system tumors; however, there have been problems regarding instability in specimen preparation and immunostaining. To overcome the weakness of this technology, the instability of immunostaining, we developed a modified R-IHC. This was achieved by switching to 4% paraformaldehyde as the fixative solution and utilizing a commercially available Polymer Refine Detection Kit, as a high-sensitivity kit, in place of the secondary antibodies. In this study, we tested the modified R-IHC by evaluating rapid immunostaining on new staining items in 94 brain tumor removal cases, which took place at Tokyo Women's Medical University from 2014 to 2015. The results showed that, based on GFAP and p53 markers, the modified method obtained a higher stability in specimens than the standard rapid immunostaining method. It also achieved stainability on the same level as that of a permanent specimen. The modified method tested 86.6% (46/53) and 82.8% (24/29) in pHH3 and ATRX, respectively, in the percentage of correct classification (PCC) against the permanent specimens, and 100% (7/7) in the PCC against malignant lymphomas and gliomas that used CD20/CD3 for discrimination. We concluded that the modified R-IHC method indicated a higher stainability and PCC against the permanent specimens in comparison to the standard method in GFAP, p53, CD20/CD3, pHH3, and ATRX.

  10. The Assessment and Validation of Mini-Compact Tension Test Specimen Geometry and Progress in Establishing Technique for Fracture Toughness Master Curves for Reactor Pressure Vessel Steels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sokolov, Mikhail A.; Nanstad, Randy K.

    Small specimens are playing the key role in evaluating properties of irradiated materials. The use of small specimens provides several advantages. Typically, only a small volume of material can be irradiated in a reactor at desirable conditions in terms of temperature, neutron flux, and neutron dose. A small volume of irradiated material may also allow for easier handling of specimens. Smaller specimens reduce the amount of radioactive material, minimizing personnel exposures and waste disposal. However, use of small specimens imposes a variety of challenges as well. These challenges are associated with proper accounting for size effects and transferability of smallmore » specimen data to the real structures of interest. Any fracture toughness specimen that can be made out of the broken halves of standard Charpy specimens may have exceptional utility for evaluation of reactor pressure vessels (RPVs) since it would allow one to determine and monitor directly actual fracture toughness instead of requiring indirect predictions using correlations established with impact data. The Charpy V-notch specimen is the most commonly used specimen geometry in surveillance programs. Assessment and validation of mini-CT specimen geometry has been performed on previously well characterized HSST Plate 13B, an A533B class 1 steel. It was shown that the fracture toughness transition temperature measured by these Mini-CT specimens is within the range of To values that were derived from various large fracture toughness specimens. Moreover, the scatter of the fracture toughness values measured by Mini-CT specimens perfectly follows the Weibull distribution function providing additional proof for validation of this geometry for the Master Curve evaluation of rector pressure vessel steels. Moreover, the International collaborative program has been developed to extend the assessment and validation efforts to irradiated weld metal. The program is underway and involves ORNL, CRIEPI, and EPRI.« less

  11. Electric reaction arising in bone subjected to mechanical loadings

    NASA Astrophysics Data System (ADS)

    Murasawa, Go; Cho, Hideo; Ogawa, Kazuma

    2006-03-01

    The aim of present study is the investigation of the electric reaction arising in bone subjected to mechanical loadings. Firstly, specimen was fabricated from femur of cow, and ultrasonic propagation in bone was measured by ultrasonic technique. Secondary, 4-point bending test was conducted up to fracture, and electric reaction arising in bone was measured during loading. Thirdly, cyclic 4-point bending test was conducted to investigate the effect of applied displacement speed on electric reaction.

  12. Corrosion of steel members strengthenened with carbon fiber reinforced polymer sheets

    NASA Astrophysics Data System (ADS)

    Bumadian, Ibrahim

    Due to many years of service at several cases of exposure at various environments there are many of steel bridges which are in need of rehabilitation. The infrastructure needs upgrading, repair or maintenance, and also strengthening, but by using an alternative as retrofits methods. The alternative retrofit method, which used fiber reinforced polymer (FRP) composite materials which their strength materials comes largely from the fiber such as carbon, glass, and aramid fiber. Of the most important materials used in the rehabilitation of infrastructure is a composite material newly developed in bonded externally carbon fiber and polymer (CFRP) sheets, which has achieved remarkable success in the rehabilitation and upgrading of structural members. This technique has many disadvantages one of them is galvanic corrosion. This study presents the effect of galvanic corrosion on the interfacial strength between carbon fiber reinforced polymer (CFRP) sheets and a steel substrate. A total of 35 double-lap joint specimens and 19 beams specimens are prepared and exposed to an aggressive service environment in conjunction with an electrical potential method accelerating corrosion damage. Six test categories are planned at a typical exposure interval of 12 hours, including five specimens per category for double-lap joint specimens. And six test categories are planned at a typical exposure interval of 12 hours, including three specimens per category for Beam section specimens. In addition one beam section specimen is control. The degree of corrosion is measured. Fourier transform infrared (FTIR) reflectance spectroscopy has been used to monitor and confirm the proposed corrosion mechanisms on the surface of CFRP. In this study we are using FTIR-spectroscopic measurement systems in the mid infrared (MIR) wavelength region (4000 - 400) cm-1 to monitor characteristic spectral features. Upon completion of corrosion processes, all specimens are monotonically loaded until failure occurs to measure their residual capacity. A relationship between the level of galvanic corrosion and the failure characteristics of steel-composite interface is established.

  13. Can CT-based patient-matched instrumentation achieve consistent rotational alignment in knee arthroplasty?

    PubMed

    Tibesku, C O; Innocenti, B; Wong, P; Salehi, A; Labey, L

    2012-02-01

    Long-term success of contemporary total knee replacements relies to a large extent on proper implant alignment. This study was undertaken to test whether specimen-matched cutting blocks based on computed axial tomography (CT) scans could provide accurate rotational alignment of the femoral component. CT scans of five fresh frozen full leg cadaver specimens, equipped with infrared reflective markers, were used to produce a specimen-matched femoral cutting block. Using those blocks, the bone cuts were made to implant a bi-compartmental femoral component. Rotational alignment of the components in the horizontal plane was determined using an optical measurement system and compared with all relevant rotational reference axes identified on the CT scans. Average rotational alignment for the bi-compartmental component in the horizontal plane was 1.9° (range 0°-6.3°; standard deviation 2.6°). One specimen that showed the highest deviation from the planned alignment also featured a completely degraded medial articular surface. The CT-based specimen-matched cutting blocks achieved good rotational alignment accuracy except for one specimen with badly damaged cartilage. In such cases, imaging techniques that visualize the cartilage layer might be more suitable to design cutting blocks, as they will provide a better fit and increased surface support.

  14. Accuracy and Measurement Error of the Medial Clear Space of the Ankle.

    PubMed

    Metitiri, Ogheneochuko; Ghorbanhoseini, Mohammad; Zurakowski, David; Hochman, Mary G; Nazarian, Ara; Kwon, John Y

    2017-04-01

    Measurement of the medial clear space (MCS) is commonly used to assess deltoid ligament competency and mortise stability when managing ankle fractures. Lacking knowledge of the true anatomic width measured, previous studies have been unable to measure accuracy of measurement. The purpose of this study was to determine MCS measurement error and accuracy and any influencing factors. Using 3 normal transtibial ankle cadaver specimens, deltoid and syndesmotic ligaments were transected and the mortise widened and affixed at a width of 6 mm (specimen 1) and 4 mm (specimen 2). The mortise was left intact in specimen 3. Radiographs were obtained of each cadaver at varying degrees of rotation. Radiographs were randomized, and providers measured the MCS using a standardized technique. Lack of accuracy as well as lack of precision in measurement of the medial clear space compared to a known anatomic value was present for all 3 specimens tested. There were no significant differences in mean delta with regard to level of training for specimens 1 and 2; however, with specimen 3, staff physicians showed increased measurement accuracy compared with trainees. Accuracy and precision of MCS measurements are poor. Provider experience did not appear to influence accuracy and precision of measurements for the displaced mortise. This high degree of measurement error and lack of precision should be considered when deciding treatment options based on MCS measurements.

  15. Enzyme-linked immunosorbent assay for detection of pertussis immunoglobulin A in nasopharyngeal secretions as an indicator of recent infection.

    PubMed Central

    Goodman, Y E; Wort, A J; Jackson, F L

    1981-01-01

    An enzyme-linked immunosorbent assay was developed for detection of immunoglobulin A (IgA) antibody to Bordetella pertussis (PsIgA) in nasopharyngeal secretions as an indicator of recent infection. Secretion specimens submitted for pertussis culture were examined for PsIgA by this technique. Of 348 specimens tested, B. pertussis was cultured from 57, and PsIgA was detected in 8 culture-positive and 40 culture-negative specimens. The average time between onset of symptoms and specimen collection for the culture-positive, PsIgA-negative specimens was 10 days; for the culture-positive, PsIgA-positive specimens, 15 days; and for the culture-negative, PsIgA-positive specimens, 36 days. Examination of paired samples available from several culture-proven cases demonstrated conversion from a negative PsIgA in the early sample to a positive PsIgA in the follow-up sample. Our results indicate that PsIgA is produced during natural human infection and does not arise as a result of parenteral vaccination. PsIgA usually appears in the nasopharyngeal secretions during the second or third week of illness and persists for at least 3 months. The detection of PsIgA in secretions may be a valuable diagnostic aid in culture-negative patients with pertussis. Images PMID:6259201

  16. Influence of laser surface treated on the characterization and corrosion behavior of Al-Fe aerospace alloys

    NASA Astrophysics Data System (ADS)

    Pariona, Moisés Meza; Teleginski, Viviane; dos Santos, Kelly; de Lima, Angela A. O. C.; Zara, Alfredo J.; Micene, Katieli Tives; Riva, Rudimar

    2013-07-01

    In this research laser surface remelting without protective coating with a 2 kW Yb-fiber laser (IPG YLR-2000S) was applied in the Al-1.5 wt.%Fe alloy in order to investigate the layer treated with different techniques of superficial characterization, thereby, the technique of optical microscopy, atomic force microscopy and low-angle X-ray diffraction were used. The present work mainly focuses on the corrosion study by diverse techniques in aggressive environment of the laser-treated area and the substrate material was carried out, thereby, at open circuit potential testing, the results have shown a displacement to more anodic values in the corrosion potential for the laser-treated specimen when compared to the untreated specimen; in potentiodynamic polarization tests have shown that as a result of the laser treatment, the corrosion current can be reduced by as much as ten times, and a passive region was obtained, which served as an effective barrier for reducing anodic dissolution and finally, the result in cyclic polarization curves of the untreated sample there was a greater area of the hysteresis loop, implying that it is more susceptible to corrosion. This study was complemented by other techniques mentioned above in order to elucidate this study. Laser surface remelting process has definitely modified the surface film, which results in higher corrosion resistance, a large range of passivation and a lower area of the hysteresis loop.

  17. SurePath Specimens Versus ThinPrep Specimen Types on the COBAS 4800 Platform: High-Risk HPV Status and Cytology Correlation in an Ethnically Diverse Bronx Population.

    PubMed

    Naeem, R C; Goldstein, D Y; Einstein, Mark H; Ramos Rivera, G; Schlesinger, K; Khader, S N; Suhrland, M; Fox, A S

    2017-08-01

    To compare the cytologic preparations of 130 cervical specimens (from women of various ethnicities at high risk for human papillomavirus [HPV] infection) using the SurePath (SP) collection system with specimens gathered using the ThinPrep (TP) system, as processed on the Cobas 4800 analyzer, to determine which collection method more accurately identifies HPV infection. In our prospective study, specimens were collected from 130 women of various ethnicities residing in or near Bronx County, NY. The SP-collected specimen was first processed for cytologic findings; if clinical HPV testing was requested on that specimen, it was tested using Hybrid Capture II (HC2) methodology. We tested the remnant SP-collected cell concentrate using the Cobas analyzer. Then, the TP-collected and SP-collected specimens were tested in the same run on that analyzer, and the results were compared. We also compared the results with the concurrent cytologic findings. The results were concordant for overall HR-HPV status in 93.8% of cases. Also, a statistically significant lower cycle threshold value was observed with Cobas testing of specimen concentrates tested via the BD SurePath Pap Test (P = .001), suggesting higher sensitivity compared with specimens tested via the ThinPrep Pap Test. Cobas 4800 HPV testing of SP-collected specimen concentrates yields comparable results to TP-collected specimen concentrates. Based on the limited data that we derived, SP collection may be a more favorable methodology than TP collection for HPV testing of individuals at high risk in our ethnically diverse, urban patient population. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  18. Recent development in low-constraint fracture toughness testing for structural integrity assessment of pipelines

    NASA Astrophysics Data System (ADS)

    Kang, Jidong; Gianetto, James A.; Tyson, William R.

    2018-03-01

    Fracture toughness measurement is an integral part of structural integrity assessment of pipelines. Traditionally, a single-edge-notched bend (SE(B)) specimen with a deep crack is recommended in many existing pipeline structural integrity assessment procedures. Such a test provides high constraint and therefore conservative fracture toughness results. However, for girth welds in service, defects are usually subjected to primarily tensile loading where the constraint is usually much lower than in the three-point bend case. Moreover, there is increasing use of strain-based design of pipelines that allows applied strains above yield. Low-constraint toughness tests represent more realistic loading conditions for girth weld defects, and the corresponding increased toughness can minimize unnecessary conservatism in assessments. In this review, we present recent developments in low-constraint fracture toughness testing, specifically using single-edgenotched tension specimens, SENT or SE(T). We focus our review on the test procedure development and automation, round-robin test results and some common concerns such as the effect of crack tip, crack size monitoring techniques, and testing at low temperatures. Examples are also given of the integration of fracture toughness data from SE(T) tests into structural integrity assessment.

  19. Standardized pivot shift test improves measurement accuracy.

    PubMed

    Hoshino, Yuichi; Araujo, Paulo; Ahlden, Mattias; Moore, Charity G; Kuroda, Ryosuke; Zaffagnini, Stefano; Karlsson, Jon; Fu, Freddie H; Musahl, Volker

    2012-04-01

    The variability of the pivot shift test techniques greatly interferes with achieving a quantitative and generally comparable measurement. The purpose of this study was to compare the variation of the quantitative pivot shift measurements with different surgeons' preferred techniques to a standardized technique. The hypothesis was that standardizing the pivot shift test would improve consistency in the quantitative evaluation when compared with surgeon-specific techniques. A whole lower body cadaveric specimen was prepared to have a low-grade pivot shift on one side and high-grade pivot shift on the other side. Twelve expert surgeons performed the pivot shift test using (1) their preferred technique and (2) a standardized technique. Electromagnetic tracking was utilized to measure anterior tibial translation and acceleration of the reduction during the pivot shift test. The variation of the measurement was compared between the surgeons' preferred technique and the standardized technique. The anterior tibial translation during pivot shift test was similar between using surgeons' preferred technique (left 24.0 ± 4.3 mm; right 15.5 ± 3.8 mm) and using standardized technique (left 25.1 ± 3.2 mm; right 15.6 ± 4.0 mm; n.s.). However, the variation in acceleration was significantly smaller with the standardized technique (left 3.0 ± 1.3 mm/s(2); right 2.5 ± 0.7 mm/s(2)) compared with the surgeons' preferred technique (left 4.3 ± 3.3 mm/s(2); right 3.4 ± 2.3 mm/s(2); both P < 0.01). Standardizing the pivot shift test maneuver provides a more consistent quantitative evaluation and may be helpful in designing future multicenter clinical outcome trials. Diagnostic study, Level I.

  20. Carbon Nanofiber Cement Sensors to Detect Strain and Damage of Concrete Specimens Under Compression

    PubMed Central

    Baeza, F. Javier; Garcés, Pedro

    2017-01-01

    Cement composites with nano-additions have been vastly studied for their functional applications, such as strain and damage sensing. The capacity of a carbon nanofiber (CNF) cement paste has already been tested. However, this study is focused on the use of CNF cement composites as sensors in regular concrete samples. Different measuring techniques and humidity conditions of CNF samples were tested to optimize the strain and damage sensing of this material. In the strain sensing tests (for compressive stresses up to 10 MPa), the response depends on the maximum stress applied. The material was more sensitive at higher loads. Furthermore, the actual load time history did not influence the electrical response, and similar curves were obtained for different test configurations. On the other hand, damage sensing tests proved the capability of CNF cement composites to measure the strain level of concrete samples, even for loads close to the material’s strength. Some problems were detected in the strain transmission between sensor and concrete specimens, which will require specific calibration of each sensor one attached to the structure. PMID:29186797

  1. Carbon Nanofiber Cement Sensors to Detect Strain and Damage of Concrete Specimens Under Compression.

    PubMed

    Galao, Oscar; Baeza, F Javier; Zornoza, Emilio; Garcés, Pedro

    2017-11-24

    Cement composites with nano-additions have been vastly studied for their functional applications, such as strain and damage sensing. The capacity of a carbon nanofiber (CNF) cement paste has already been tested. However, this study is focused on the use of CNF cement composites as sensors in regular concrete samples. Different measuring techniques and humidity conditions of CNF samples were tested to optimize the strain and damage sensing of this material. In the strain sensing tests (for compressive stresses up to 10 MPa), the response depends on the maximum stress applied. The material was more sensitive at higher loads. Furthermore, the actual load time history did not influence the electrical response, and similar curves were obtained for different test configurations. On the other hand, damage sensing tests proved the capability of CNF cement composites to measure the strain level of concrete samples, even for loads close to the material's strength. Some problems were detected in the strain transmission between sensor and concrete specimens, which will require specific calibration of each sensor one attached to the structure.

  2. In situ thermomechanical testing methods for micro/nano-scale materials.

    PubMed

    Kang, Wonmo; Merrill, Marriner; Wheeler, Jeffrey M

    2017-02-23

    The advance of micro/nanotechnology in energy-harvesting, micropower, electronic devices, and transducers for automobile and aerospace applications has led to the need for accurate thermomechanical characterization of micro/nano-scale materials to ensure their reliability and performance. This persistent need has driven various efforts to develop innovative experimental techniques that overcome the critical challenges associated with precise mechanical and thermal control of micro/nano-scale specimens during material characterization. Here we review recent progress in the development of thermomechanical testing methods from miniaturized versions of conventional macroscopic test systems to the current state of the art of in situ uniaxial testing capabilities in electron microscopes utilizing either indentation-based microcompression or integrated microsystems. We discuss the major advantages/disadvantages of these methods with respect to specimen size, range of temperature control, ease of experimentation and resolution of the measurements. We also identify key challenges in each method. Finally, we summarize some of the important discoveries that have been made using in situ thermomechanical testing and the exciting research opportunities still to come in micro/nano-scale materials.

  3. Characterization of Machine Variability and Progressive Heat Treatment in Selective Laser Melting of Inconel 718

    NASA Technical Reports Server (NTRS)

    Prater, T.; Tilson, W.; Jones, Z.

    2015-01-01

    The absence of an economy of scale in spaceflight hardware makes additive manufacturing an immensely attractive option for propulsion components. As additive manufacturing techniques are increasingly adopted by government and industry to produce propulsion hardware in human-rated systems, significant development efforts are needed to establish these methods as reliable alternatives to conventional subtractive manufacturing. One of the critical challenges facing powder bed fusion techniques in this application is variability between machines used to perform builds. Even with implementation of robust process controls, it is possible for two machines operating at identical parameters with equivalent base materials to produce specimens with slightly different material properties. The machine variability study presented here evaluates 60 specimens of identical geometry built using the same parameters. 30 samples were produced on machine 1 (M1) and the other 30 samples were built on machine 2 (M2). Each of the 30-sample sets were further subdivided into three subsets (with 10 specimens in each subset) to assess the effect of progressive heat treatment on machine variability. The three categories for post-processing were: stress relief, stress relief followed by hot isostatic press (HIP), and stress relief followed by HIP followed by heat treatment per AMS 5664. Each specimen (a round, smooth tensile) was mechanically tested per ASTM E8. Two formal statistical techniques, hypothesis testing for equivalency of means and one-way analysis of variance (ANOVA), were applied to characterize the impact of machine variability and heat treatment on six material properties: tensile stress, yield stress, modulus of elasticity, fracture elongation, and reduction of area. This work represents the type of development effort that is critical as NASA, academia, and the industrial base work collaboratively to establish a path to certification for additively manufactured parts. For future flight programs, NASA and its commercial partners will procure parts from vendors who will use a diverse range of machines to produce parts and, as such, it is essential that the AM community develop a sound understanding of the degree to which machine variability impacts material properties.

  4. Laser-assisted cartilage reshaping: in vitro and in vivo animal studies

    NASA Astrophysics Data System (ADS)

    Wang, Zhi; Pankratov, Michail M.; Perrault, Donald F., Jr.; Shapshay, Stanley M.

    1995-05-01

    Correction of cartilaginous defects in the head and neck area remains a challenge for the surgeon. This study investigated a new technique for laser-assisted cartilage reshaping. The pulsed 1.44 micrometers Nd:YAG laser was used in vitro and in vivo experiments to irradiate cartilage to change it's shape without carbonization or vaporization of tissue. Two watts of average power in non contact manner was used to irradiate and reshape the cartilage. The extracted reshaped cartilage specimens underwent testing of elastic force with a computer assisted measurement system that recorded the changes in elastic force in the specimens from 1 hr to 11 days post-irradiation. An animal model of defective tracheal cartilage (collapsed tracheal wall) was created, allowed to heal for 6 weeks and then corrected endoscopically with the laser-assisted technique. The results of the in vitro and in vivo investigations demonstrated that it was possible to alter the cartilage and that cartilage would retain its new shape. The clinical significance of the technique is evident and warrants further animal studies and clinical trials.

  5. New Technique for Tibiotalar Arthrodesis Using a New Intramedullary Nail Device: A Cadaveric Study

    PubMed Central

    Eisenstein, Emmanuel D.; Rodriguez, Mario

    2016-01-01

    Introduction. Ankle arthrodesis is performed in a variety of methods. We propose a new technique for tibiotalar arthrodesis using a newly designed intramedullary nail. Methods. We proposed development of an intramedullary device for ankle arthrodesis which spared the subtalar joint using a sinus tarsi approach. Standard saw bones models and computer assisted modeling and stress analysis were used to develop different nail design geometries and determine the feasibility of insertion. After the final design was constructed, the device was tested on three cadaveric specimens. Results. Four basic nail geometries were developed. The optimal design was composed of two relatively straight segments, each with a different radius of curvature for their respective tibial and talar component. We successfully implemented this design into three cadaveric specimens. Conclusion. Our newly designed tibiotalar nail provides a new technique for isolated tibiotalar fusion. It utilizes the advantages of a tibiotalar calcaneal nail and spares the subtalar joint. This design serves as the foundation for future research to include compression options across the tibiotalar joint and eventual transition to clinical practice. PMID:27818800

  6. New Technique for Tibiotalar Arthrodesis Using a New Intramedullary Nail Device: A Cadaveric Study.

    PubMed

    Eisenstein, Emmanuel D; Rodriguez, Mario; Abdelgawad, Amr A

    2016-01-01

    Introduction . Ankle arthrodesis is performed in a variety of methods. We propose a new technique for tibiotalar arthrodesis using a newly designed intramedullary nail. Methods . We proposed development of an intramedullary device for ankle arthrodesis which spared the subtalar joint using a sinus tarsi approach. Standard saw bones models and computer assisted modeling and stress analysis were used to develop different nail design geometries and determine the feasibility of insertion. After the final design was constructed, the device was tested on three cadaveric specimens. Results . Four basic nail geometries were developed. The optimal design was composed of two relatively straight segments, each with a different radius of curvature for their respective tibial and talar component. We successfully implemented this design into three cadaveric specimens. Conclusion . Our newly designed tibiotalar nail provides a new technique for isolated tibiotalar fusion. It utilizes the advantages of a tibiotalar calcaneal nail and spares the subtalar joint. This design serves as the foundation for future research to include compression options across the tibiotalar joint and eventual transition to clinical practice.

  7. High strain rate characterization of soft materials: past, present and possible futures

    NASA Astrophysics Data System (ADS)

    Siviour, Clive

    2015-06-01

    The high strain rate properties of low impedance materials have long been of interest to the community: the very first paper by Kolsky on his eponymous bars included data from man-made polymers and natural rubber. However, it has also long been recognized that characterizing soft or low impedance specimens under dynamic loading presents a number of challenges, mainly owing to the low sound speed in, and low stresses supported by, these materials. Over the past 20 years, significant progress has been made in high rate testing techniques, including better experimental design, more sensitive data acquisition and better understanding of specimen behavior. Further, a new generation of techniques, in which materials are characterized using travelling waves, rather than in a state of static equilibrium, promise to turn those properties that were previously a drawback into an advantage. This paper will give an overview of the history of high rate characterization, the current state of the art after an exciting couple of decades and some of the techniques currently being developed that have the potential to offer increased quality data in the future.

  8. Effect of the Cold-Sprayed Aluminum Coating-Substrate Interface Morphology on Bond Strength for Aircraft Repair Application

    NASA Astrophysics Data System (ADS)

    Blochet, Quentin; Delloro, Francesco; N'Guyen, Franck; Jeulin, Dominique; Borit, François; Jeandin, Michel

    2017-04-01

    This article is dealing with the effects of surface preparation of the substrate on aluminum cold-sprayed coating bond strength. Different sets of AA2024-T3 specimens have been coated with pure Al 1050 feedstock powder, using a conventional cold spray coating technique. The sets were grit-blasted (GB) before coating. The study focuses on substrate surface topography evolution before coating and coating-substrate interface morphology after coating. To study coating adhesion by LASAT® technique for each set, specimens with and without preceding GB treatment were tested in load-controlled conditions. Then, several techniques were used to evaluate the effects of substrate surface treatment on the final coating mechanical properties. Irregularities induced by the GB treatment modify significantly the interface morphology. Results showed that particle anchoring was improved dramatically by the presence of craters. The substrate surface was characterized by numerous anchors. Numerical simulation results exhibited the increasing deformation of particle onto the grit-blasted surface. In addition, results showed a strong relationship between the coating-substrate bond strength on the deposited material and surface preparation.

  9. 9 CFR 93.404 - Import permits for ruminants and for ruminant test specimens for diagnostic purposes; and...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... ruminant test specimens for diagnostic purposes; and reservation fees for space at quarantine facilities... for ruminants and for ruminant test specimens for diagnostic purposes; and reservation fees for space...) For ruminants and ruminant test specimens for diagnostic screening purposes intended for importation...

  10. 9 CFR 93.404 - Import permits for ruminants and for ruminant test specimens for diagnostic purposes; and...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... ruminant test specimens for diagnostic purposes; and reservation fees for space at quarantine facilities... for ruminants and for ruminant test specimens for diagnostic purposes; and reservation fees for space...) For ruminants and ruminant test specimens for diagnostic screening purposes intended for importation...

  11. 9 CFR 93.404 - Import permits for ruminants and for ruminant test specimens for diagnostic purposes; and...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... ruminant test specimens for diagnostic purposes; and reservation fees for space at quarantine facilities... for ruminants and for ruminant test specimens for diagnostic purposes; and reservation fees for space...) For ruminants and ruminant test specimens for diagnostic screening purposes intended for importation...

  12. 9 CFR 93.404 - Import permits for ruminants and for ruminant test specimens for diagnostic purposes; and...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... ruminant test specimens for diagnostic purposes; and reservation fees for space at quarantine facilities... for ruminants and for ruminant test specimens for diagnostic purposes; and reservation fees for space...) For ruminants and ruminant test specimens for diagnostic screening purposes intended for importation...

  13. 9 CFR 93.404 - Import permits for ruminants and for ruminant test specimens for diagnostic purposes; and...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... ruminant test specimens for diagnostic purposes; and reservation fees for space at quarantine facilities... for ruminants and for ruminant test specimens for diagnostic purposes; and reservation fees for space...) For ruminants and ruminant test specimens for diagnostic screening purposes intended for importation...

  14. Apparatus for automated testing of biological specimens

    DOEpatents

    Layne, Scott P.; Beugelsdijk, Tony J.

    1999-01-01

    An apparatus for performing automated testing of infections biological specimens is disclosed. The apparatus comprise a process controller for translating user commands into test instrument suite commands, and a test instrument suite comprising a means to treat the specimen to manifest an observable result, and a detector for measuring the observable result to generate specimen test results.

  15. Flexural Behavior of GFRP Tubes Filled with Magnetically Driven Concrete

    PubMed Central

    Xie, Fang; Chen, Ju; Dong, Xinlong; Feng, Bing

    2018-01-01

    Experimental investigation of GFRP (glass fiber reinforced polymer) tubes that were filled with magnetically driven concrete was carried out to study the flexural behavior of specimens under bending. Specimens having different cross section and lengths were tested. The test specimens were fabricated by filling magnetically driven concrete into the GFRP tubes and the concrete was vibrated using magnetic force. Specimens vibrated using vibrating tube were also tested for comparison. In addition, specimens having steel reinforcing bars and GFRP bars were both tested to study the effect of reinforcing bars on the magnetically driven concrete. The load-displacement curves, load-strain curves, failure mode, and ultimate strengths of test specimens were obtained. Design methods for the flexural stiffness of test specimens were also discussed in this study. PMID:29316732

  16. Flexural Behavior of GFRP Tubes Filled with Magnetically Driven Concrete.

    PubMed

    Xie, Fang; Chen, Ju; Dong, Xinlong; Feng, Bing

    2018-01-08

    Experimental investigation of GFRP (glass fiber reinforced polymer) tubes that were filled with magnetically driven concrete was carried out to study the flexural behavior of specimens under bending. Specimens having different cross section and lengths were tested. The test specimens were fabricated by filling magnetically driven concrete into the GFRP tubes and the concrete was vibrated using magnetic force. Specimens vibrated using vibrating tube were also tested for comparison. In addition, specimens having steel reinforcing bars and GFRP bars were both tested to study the effect of reinforcing bars on the magnetically driven concrete. The load-displacement curves, load-strain curves, failure mode, and ultimate strengths of test specimens were obtained. Design methods for the flexural stiffness of test specimens were also discussed in this study.

  17. Comparison of acridine orange and Gram stains for detection of microorganisms in cerebrospinal fluid and other clinical specimens.

    PubMed Central

    Lauer, B A; Reller, L B; Mirrett, S

    1981-01-01

    Acridine orange, a fluorochrome strain, is potentially superior to the Gram stain in the direct microscopic examination of clinical specimens because it gives striking differential staining between bacteria and background cells and debris. Its value in clinical laboratories was evaluated by testing 209 cerebrospinal fluids and 288 other body fluids, tissues, and exudates by both techniques. Smears were made in duplicate, fixed with methanol, stained, and examined without knowledge of the result of the companion smear or culture. Overall, acridine orange was slightly more sensitive than the Gram stain (acridine orange, 59.9%; Gram stain, 55.8%) and equally specific in detecting microorganisms. One smear was falsely positive by the Gram stain; none was falsely positive by the acridine orange stain. We conclude that acridine orange staining is a sensitive method for screening clinical specimens and reviewing selected specimens that are purulent, but negative by the Gram stain. Bloody fluids, thick exudates, and other normally difficult-to-read specimens were easily and quickly examined. We recommend, however, that positive smears be reexamined with the Gram stain to confirm the result and determine the Gram reaction of the microorganisms. PMID:6168652

  18. Confocal arthroscopy-based patient-specific constitutive models of cartilaginous tissues - II: prediction of reaction force history of meniscal cartilage specimens.

    PubMed

    Taylor, Zeike A; Kirk, Thomas B; Miller, Karol

    2007-10-01

    The theoretical framework developed in a companion paper (Part I) is used to derive estimates of mechanical response of two meniscal cartilage specimens. The previously developed framework consisted of a constitutive model capable of incorporating confocal image-derived tissue microstructural data. In the present paper (Part II) fibre and matrix constitutive parameters are first estimated from mechanical testing of a batch of specimens similar to, but independent from those under consideration. Image analysis techniques which allow estimation of tissue microstructural parameters form confocal images are presented. The constitutive model and image-derived structural parameters are then used to predict the reaction force history of the two meniscal specimens subjected to partially confined compression. The predictions are made on the basis of the specimens' individual structural condition as assessed by confocal microscopy and involve no tuning of material parameters. Although the model does not reproduce all features of the experimental curves, as an unfitted estimate of mechanical response the prediction is quite accurate. In light of the obtained results it is judged that more general non-invasive estimation of tissue mechanical properties is possible using the developed framework.

  19. An interlaminar tension strength specimen

    NASA Technical Reports Server (NTRS)

    Jackson, Wade C.; Martin, Roderick H.

    1992-01-01

    This paper describes a technique to determine interlaminar tension strength, sigma(sub 3c) of a fiber reinforced composite material using a curved beam. The specimen was a unidirectional curved beam, bent 90 degrees, with straight arms. Attached to each arm was a hinged loading mechanism which was held by the grips of a tensile testing machine. Geometry effects of the specimen, including the effects of loading arm length, inner radius, thickness, and width, were studied. The data sets fell into two categories: low strength corresponding to a macroscopic flaw related failure and high strength corresponding to a microscopic flaw related failure. From the data available, the loading arm length had no effect on sigma(sub 3c). The inner radius was not expected to have a significant effect on sigma(sub 3c), but this conclusion could not be confirmed because of differences in laminate quality for each curve geometry. The thicker specimens had the lowest value of sigma(sub 3c) because of poor laminate quality. Width was found to affect the value of sigma(sub 3c) only slightly. The wider specimens generally had a slightly lower strength since more material was under high stress, and hence, had a larger probability of containing a significant flaw.

  20. Validation of a C2-C7 cervical spine finite element model using specimen-specific flexibility data.

    PubMed

    Kallemeyn, Nicole; Gandhi, Anup; Kode, Swathi; Shivanna, Kiran; Smucker, Joseph; Grosland, Nicole

    2010-06-01

    This study presents a specimen-specific C2-C7 cervical spine finite element model that was developed using multiblock meshing techniques. The model was validated using in-house experimental flexibility data obtained from the cadaveric specimen used for mesh development. The C2-C7 specimen was subjected to pure continuous moments up to +/-1.0 N m in flexion, extension, lateral bending, and axial rotation, and the motions at each level were obtained. Additionally, the specimen was divided into C2-C3, C4-C5, and C6-C7 functional spinal units (FSUs) which were tested in the intact state as well as after sequential removal of the interspinous, ligamentum flavum, and capsular ligaments. The finite element model was initially assigned baseline material properties based on the literature, but was calibrated using the experimental motion data which was obtained in-house, while utlizing the ranges of material property values as reported in the literature. The calibrated model provided good agreement with the nonlinear experimental loading curves, and can be used to further study the response of the cervical spine to various biomechanical investigations. Copyright 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  1. Edge delamination of composite laminates subject to combined tension and torsional loading

    NASA Technical Reports Server (NTRS)

    Hooper, Steven J.

    1990-01-01

    Delamination is a common failure mode of laminated composite materials. Edge delamination is important since it results in reduced stiffness and strength of the laminate. The tension/torsion load condition is of particular significance to the structural integrity of composite helicopter rotor systems. Material coupons can easily be tested under this type of loading in servo-hydraulic tension/torsion test stands using techniques very similar to those used for the Edge Delamination Tensile Test (EDT) delamination specimen. Edge delamination of specimens loaded in tension was successfully analyzed by several investigators using both classical laminate theory and quasi-three dimensional (Q3D) finite element techniques. The former analysis technique can be used to predict the total strain energy release rate, while the latter technique enables the calculation of the mixed-mode strain energy release rates. The Q3D analysis is very efficient since it produces a three-dimensional solution to a two-dimensional domain. A computer program was developed which generates PATRAN commands to generate the finite element model. PATRAN is a pre- and post-processor which is commonly used with a variety of finite element programs such as MCS/NASTRAN. The program creates a sufficiently dense mesh at the delamination crack tips to support a mixed-mode fracture mechanics analysis. The program creates a coarse mesh in those regions where the gradients in the stress field are low (away from the delamination regions). A transition mesh is defined between these regions. This program is capable of generating a mesh for an arbitrarily oriented matrix crack. This program significantly reduces the modeling time required to generate these finite element meshes, thus providing a realistic tool with which to investigate the tension torsion problem.

  2. Comparison of FilmArray and Quantitative Real-Time Reverse Transcriptase PCR for Detection of Zaire Ebolavirus from Contrived and Clinical Specimens

    PubMed Central

    Southern, Timothy R.; Racsa, Lori D.; Albariño, César G.; Fey, Paul D.; Hinrichs, Steven H.; Murphy, Caitlin N.; Herrera, Vicki L.; Sambol, Anthony R.; Hill, Charles E.; Ryan, Emily L.; Kraft, Colleen S.; Campbell, Shelley; Sealy, Tara K.; Schuh, Amy; Ritchie, James C.; Lyon, G. Marshall; Mehta, Aneesh K.; Varkey, Jay B.; Ribner, Bruce S.; Brantly, Kent P.; Ströher, Ute; Iwen, Peter C.

    2015-01-01

    Rapid, reliable, and easy-to-use diagnostic assays for detection of Zaire ebolavirus (ZEBOV) are urgently needed. The goal of this study was to examine the agreement among emergency use authorization (EUA) tests for the detection of ZEBOV nucleic acids, including the BioFire FilmArray BioThreat (BT) panel, the FilmArray BT-E panel, and the NP2 and VP40 quantitative real-time reverse transcriptase (qRT) PCR assays from the Centers for Disease Control and Prevention (CDC). Specimens used in this study included whole blood spiked with inactivated ZEBOV at known titers and whole-blood, plasma, and urine clinical specimens collected from persons diagnosed with Ebola virus disease (EVD). The agreement for FilmArray and qRT-PCR results using contrived whole-blood specimens was 100% (6/6 specimens) for each ZEBOV dilution from 4 × 107 to 4 × 102 50% tissue culture infective dose (TCID50)/ml, as well as the no-virus negative-control sample. The limit of detection for FilmArray and qRT-PCR assays with inactivated ZEBOV, based on duplicate positive results, was determined to be 4 × 102 TCID50/ml. Rates of agreement between FilmArray and qRT-PCR results for clinical specimens from patients with EVD were 85% (23/27 specimens) for whole-blood specimens, 90% (18/20 specimens) for whole-blood specimens tested by FilmArray testing and matched plasma specimens tested by qRT-PCR testing, and 85% (11/13 specimens) for urine specimens. Among 60 specimens, eight discordant results were noted, with ZEBOV nucleic acids being detected only by FilmArray testing in four specimens and only by qRT-PCR testing in the remaining four specimens. These findings demonstrate that the rapid and easy-to-use FilmArray panels are effective tests for evaluating patients with EVD. PMID:26157148

  3. Probing Shells Against Buckling: A Nondestructive Technique for Laboratory Testing

    NASA Astrophysics Data System (ADS)

    Thompson, J. Michael T.; Hutchinson, John W.; Sieber, Jan

    2017-12-01

    This paper addresses testing of compressed structures, such as shells, that exhibit catastrophic buckling and notorious imperfection sensitivity. The central concept is the probing of a loaded structural specimen by a controlled lateral displacement to gain quantitative insight into its buckling behavior and to measure the energy barrier against buckling. This can provide design information about a structure’s stiffness and robustness against buckling in terms of energy and force landscapes. Developments in this area are relatively new but have proceeded rapidly with encouraging progress. Recent experimental tests on uniformly compressed spherical shells, and axially loaded cylinders, show excellent agreement with theoretical solutions. The probing technique could be a valuable experimental procedure for testing prototype structures, but before it can be used a range of potential problems must be examined and solved. The probing response is highly nonlinear and a variety of complications can occur. Here, we make a careful assessment of unexpected limit points and bifurcations, that could accompany probing, causing complications and possibly even collapse of a test specimen. First, a limit point in the probe displacement (associated with a cusp instability and fold) can result in dynamic buckling as probing progresses, as demonstrated in the buckling of a spherical shell under volume control. Second, various types of bifurcations which can occur on the probing path which result in the probing response becoming unstable are also discussed. To overcome these problems, we outline the extra controls over the entire structure that may be needed to stabilize the response.

  4. Intraoperative probe detecting β- decays in brain tumour radio-guided surgery

    NASA Astrophysics Data System (ADS)

    Solfaroli Camillocci, E.; Bocci, V.; Chiodi, G.; Collamati, F.; Donnarumma, R.; Faccini, R.; Mancini Terracciano, C.; Marafini, M.; Mattei, I.; Muraro, S.; Recchia, L.; Rucinski, A.; Russomando, A.; Toppi, M.; Traini, G.; Morganti, S.

    2017-02-01

    Radio-guided surgery (RGS) is a technique to intraoperatively detect tumour remnants, favouring a radical resection. Exploiting β- emitting tracers provides a higher signal to background ratio compared to the established technique with γ radiation, allowing the extension of the RGS applicability range. We developed and tested a detector based on para-terphenyl scintillator with high sensitivity to low energy electrons and almost transparent to γs to be used as intraoperative probe for RGS with β- emitting tracer. Portable read out electronics was customised to match the surgeon needs. This probe was used for preclinical test on specific phantoms and a test on "ex vivo" specimens from patients affected by meningioma showing very promising results for the application of this new technique on brain tumours. In this paper, the prototype of the intraoperative probe and the tests are discussed; then, the results on meningioma are used to make predictions on the performance of the probe detecting residuals of a more challenging and more interesting brain tumour: the glioma.

  5. Are the evidences of forensic entomology preserved in ethanol suitable for SEM studies?

    PubMed

    López-Esclapez, Raquel; García, María-Dolores; Arnaldos, María-Isabel; Presa, Juan José; Ubero-Pascal, Nicolás

    2014-07-01

    In forensic practice, the use of arthropod evidences to estimate the postmortem interval is a very good approach when the elapsed time from death is long, but it requires the correct identification of the specimens. This is a crucial step, not always easy to achieve, in particular when dealing with immature specimens. In this case, scanning electronic microscopy (SEM) can be useful, but the techniques used to preserve specimens in forensic practice are usually different from those used to prepare specimens for SEM studies. To determine whether forensic evidences preserving techniques are also compatible with SEM analysis, we have compared specimens of all the immature stages of Calliphora vicina Robineau-Desvoidy, 1830 (Diptera, Calliphoridae) preserved in 70% ethanol, with others prepared with aldehydic fixative techniques that are more appropriate for SEM studies. At the same time, two drying techniques have also been compared with both fixative techniques, the critical point drying and air-drying following with hexamethyldisilizane treatment (HMDS). Our results indicate that there are not basis against recommending the use of ethanol to preserve forensic entomological evidences and that both drying methods appear to offer good results for second and third instar larvae, although HMDS behaves better with eggs and pupae. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Ceramic Matrix Composite Vane Subelement Burst Testing

    NASA Technical Reports Server (NTRS)

    Brewer, David N.; Verrilli, Michael; Calomino, Anthony

    2006-01-01

    Burst tests were performed on Ceramic Matrix Composite (CMC) vane specimens, manufactured by two vendors, under the Ultra Efficient Engine Technology (UEET) project. Burst specimens were machined from the ends of 76mm long vane sub-elements blanks and from High Pressure Burner Rig (HPBR) tested specimens. The results of burst tests will be used to compare virgin specimens with specimens that have had an Environmental Barrier Coating (EBC) applied, both HPBR tested and untested, as well as a comparison between vendors.

  7. Monitoring small-crack growth by the replication method

    NASA Technical Reports Server (NTRS)

    Swain, Mary H.

    1992-01-01

    The suitability of the acetate replication method for monitoring the growth of small cracks is discussed. Applications of this technique are shown for cracks growing at the notch root in semicircular-edge-notch specimens of a variety of aluminum alloys and one steel. The calculated crack growth rate versus Delta K relationship for small cracks was compared to that for large cracks obtained from middle-crack-tension specimens. The primary advantage of this techinque is that it provides an opportunity, at the completion of the test, to go backward in time towards the crack initiation event and 'zoom in' on areas of interest on the specimen surface with a resolution of about 0.1 micron. The primary disadvantage is the inability to automate the process. Also, for some materials, the replication process may alter the crack-tip chemistry or plastic zone, thereby affecting crack growth rates.

  8. Enhancing Ultimate Compressive Strength of Notch Embedded Steel Cylinders Using Overwrap CFRP Patch

    NASA Astrophysics Data System (ADS)

    Kabir, Mohammad Z.; Nazari, Alireza

    2012-06-01

    In this study, the application of Fiber Reinforced Polymer (FRP) patch for strengthening of the damaged area in thin walled steel cylinders under compression loading was investigated. In this direction, some experimental tests were carried out on the selected notch induced specimens with unique diameter-to-thickness ratio (D/t). The obtained results were compared to the intact cylinder in order to find out the reduction effect of notch on the buckling load of cylinders. Following that, the notched specimens were treated using externally FRP by wrapping around the notched area and the stability strength of the retrofitted specimens was measured experimentally. The investigation was also carried out in numerical analysis using FEM in order to develop the proposed technique for determination of optimum FRP configurations and also better understanding of the experimental observations considering the nonlinear behavior and failure modes for composite member.

  9. CARES/Life Software for Designing More Reliable Ceramic Parts

    NASA Technical Reports Server (NTRS)

    Nemeth, Noel N.; Powers, Lynn M.; Baker, Eric H.

    1997-01-01

    Products made from advanced ceramics show great promise for revolutionizing aerospace and terrestrial propulsion, and power generation. However, ceramic components are difficult to design because brittle materials in general have widely varying strength values. The CAPES/Life software eases this task by providing a tool to optimize the design and manufacture of brittle material components using probabilistic reliability analysis techniques. Probabilistic component design involves predicting the probability of failure for a thermomechanically loaded component from specimen rupture data. Typically, these experiments are performed using many simple geometry flexural or tensile test specimens. A static, dynamic, or cyclic load is applied to each specimen until fracture. Statistical strength and SCG (fatigue) parameters are then determined from these data. Using these parameters and the results obtained from a finite element analysis, the time-dependent reliability for a complex component geometry and loading is then predicted. Appropriate design changes are made until an acceptable probability of failure has been reached.

  10. Techniques for determining thermal conductivity and heat capacity under hydrostatic pressure

    NASA Astrophysics Data System (ADS)

    Andersson, S.; Bäckström, G.

    1986-08-01

    The paper describes a method for measuring the pressure dependence of the thermal conductivity and the heat capacity of hard materials and single crystals. Two parallel metal strips are evaporated onto a flat surface of the specimen, one being used as a heater, the other as a resistance thermometer. The appropriate theoretical expression for a specimen in a liquid medium is fitted to the temperature, sampled at constant time intervals. The thermophysical properties of the liquid high-pressure medium are taken from hot-wire experiments. The procedure has been thoroughly tested at atmospheric pressure using an MgO crystal and glass as specimens and liquids of different characteristics in lieu of high-pressure medium. The accuracy attainable was found to be 3% or better, the standard deviation of the measurements being about 0.3%. The potential of the system was demonstrated by measurements on single-crystal MgO under pressures up to 1 GPa.

  11. Examining Mechanical Strength Characteristics of Selective Inhibition Sintered HDPE Specimens Using RSM and Desirability Approach

    NASA Astrophysics Data System (ADS)

    Rajamani, D.; Esakki, Balasubramanian

    2017-09-01

    Selective inhibition sintering (SIS) is a powder based additive manufacturing (AM) technique to produce functional parts with an inexpensive system compared with other AM processes. Mechanical properties of SIS fabricated parts are of high dependence on various process parameters importantly layer thickness, heat energy, heater feedrate, and printer feedrate. In this paper, examining the influence of these process parameters on evaluating mechanical properties such as tensile and flexural strength using Response Surface Methodology (RSM) is carried out. The test specimens are fabricated using high density polyethylene (HDPE) and mathematical models are developed to correlate the control factors to the respective experimental design response. Further, optimal SIS process parameters are determined using desirability approach to enhance the mechanical properties of HDPE specimens. Optimization studies reveal that, combination of high heat energy, low layer thickness, medium heater feedrate and printer feedrate yielded superior mechanical strength characteristics.

  12. Effect of Cooling Rate on SCC Susceptibility of β-Processed Ti-6Al-4V Alloy in 0.6M NaCl Solution

    NASA Astrophysics Data System (ADS)

    Ahn, Soojin; Park, Jiho; Jeong, Daeho; Sung, Hyokyung; Kwon, Yongnam; Kim, Sangshik

    2018-03-01

    The effects of cooling rate on the stress corrosion cracking (SCC) susceptibility of β-processed Ti-6Al-4V (Ti64) alloy, including BA/S specimen with furnace cooling and BQ/S specimen with water quenching, were investigated in 0.6M NaCl solution under various applied potentials using a slow strain rate test technique. It was found that the SCC susceptibility of β-processed Ti64 alloy in aqueous NaCl solution decreased with fast cooling rate, which was particularly substantial under an anodic applied potential. The micrographic and fractographic analyses suggested that the enhancement with fast cooling rate was related to the random orientation of acicular α platelets in BQ/S specimen. Based on the experimental results, the effect of cooling rate on the SCC behavior of β-processed Ti64 alloy in aqueous NaCl solution was discussed.

  13. Measurement of the mechanical properties of car body sheet steels at high strain rates and non ambient temperature

    NASA Astrophysics Data System (ADS)

    Bleck, W.; Larour, P.

    2003-09-01

    Crash behaviour and light weight have become the major design criteria for car bodies. Modem high strength steels offer appropriate solutions for these requirements. The prediction of the crash behaviour in simulation programs requires the information on materials behaviour during dynamic testing. The reduction of the signal waviness and the inertia effects at strain rates above 50s^{-1} are major issues in dynamic tensile testing. Damping techniques or load measurement on the sample itself are the common way to reduce oscillations. Strain measurement from the piston displacement or from optical devices on the specimen itself are also compared. Advantages and drawbacks of those various measurement techniques are presented.

  14. Joint strength of a solid oxide fuel cell glass-ceramic sealant with metallic interconnect in a reducing environment

    NASA Astrophysics Data System (ADS)

    Lin, Chih-Kuang; Liu, Yu-An; Wu, Si-Han; Liu, Chien-Kuo; Lee, Ruey-Yi

    2015-04-01

    Effects of reducing environment and thermal aging on the joint strength of a BaO-B2O3-Al2O3-SiO2 glass-ceramic sealant (GC-9) with a ferritic-stainless-steel interconnect (Crofer 22 H) for planar solid oxide fuel cells are investigated. A technique is developed for conducting mechanical tests at room temperature and 800 °C in H2-7 vol% H2O under shear and tensile loadings. Given an aged condition and loading mode, the joint strength at 800 °C is lower than that at room temperature in the given humidified hydrogen atmosphere. A thermal aging at 800 °C in H2-7 vol% H2O for 100 h or 1000 h enhances both shear and tensile joint strengths at room temperature but degrades them at 800 °C in the same reducing environment. Non-aged specimens show a comparable joint strength and fracture mode when tested in humidified hydrogen and in air under a given loading mode and testing temperature. The shear strength at 800 °C for joint specimens after a 1000-h thermal aging at 800 °C in air or humidified hydrogen is reduced by a similar extent of 19%, compared to the counterpart of non-aged joint specimens tested in the same oxidizing or reducing environment.

  15. Multiaxial constitutive behavior of an interstitial-free steel: Measurements through X-ray and digital image correlation

    PubMed Central

    Jeong, Y.; Iadicola, M.A.; Gnäupel-Herold, T.; Creuziger, A.

    2017-01-01

    Constitutive behaviors of an interstitial-free steel sample were measured using an augmented Marciniak experiment. In these tests, multiaxial strain field data of the flat specimens were measured by the digital image correlation technique. In addition, the flow stress was measured using an X-ray diffractometer. The flat specimens in three different geometries were tested in order to achieve 1) balanced biaxial strain, and plane strain tests with zero strain in either 2) rolling direction or 3) transverse direction. The multiaxial stress and strain data were processed to obtain plastic work contours with reference to a uniaxial tension test along the rolling direction. The experimental results show that the mechanical behavior of the subjected specimen deviates significantly from isotropic behavior predicted by the von Mises yield criterion. The initial yield loci measured by a Marciniak tester is in good agreement with what is predicted by Hill's yield criterion. However, as deformation increases beyond the vonMises strain of 0.05, the shape of the work contour significantly deviates from that of Hill's yield locus. A prediction made by a viscoplastic self-consistent model is in better agreement with the experimental observation than the Hill yield locus with the isotropic work-hardening rule. However, none of the studied models matched the initial or evolving anisotropic behaviors of the interstitial-free steel measured by the augmented Marciniak experiment. PMID:28690400

  16. Multiaxial constitutive behavior of an interstitial-free steel: Measurements through X-ray and digital image correlation.

    PubMed

    Jeong, Y; Iadicola, M A; Gnäupel-Herold, T; Creuziger, A

    2016-06-15

    Constitutive behaviors of an interstitial-free steel sample were measured using an augmented Marciniak experiment. In these tests, multiaxial strain field data of the flat specimens were measured by the digital image correlation technique. In addition, the flow stress was measured using an X-ray diffractometer. The flat specimens in three different geometries were tested in order to achieve 1) balanced biaxial strain, and plane strain tests with zero strain in either 2) rolling direction or 3) transverse direction. The multiaxial stress and strain data were processed to obtain plastic work contours with reference to a uniaxial tension test along the rolling direction. The experimental results show that the mechanical behavior of the subjected specimen deviates significantly from isotropic behavior predicted by the von Mises yield criterion. The initial yield loci measured by a Marciniak tester is in good agreement with what is predicted by Hill's yield criterion. However, as deformation increases beyond the vonMises strain of 0.05, the shape of the work contour significantly deviates from that of Hill's yield locus. A prediction made by a viscoplastic self-consistent model is in better agreement with the experimental observation than the Hill yield locus with the isotropic work-hardening rule. However, none of the studied models matched the initial or evolving anisotropic behaviors of the interstitial-free steel measured by the augmented Marciniak experiment.

  17. Dynamic Response of Layered TiB/Ti Functionally Graded Material Specimens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Byrd, Larry; Beberniss, Tim; Chapman, Ben

    2008-02-15

    This paper covers the dynamic response of rectangular (25.4x101.6x3.175 mm) specimens manufactured from layers of TiB/Ti. The layers contained volume fractions of TiB that varied from 0 to 85% and thus formed a functionally graded material. Witness samples of the 85% TiB material were also tested to provide a baseline for the statistical variability of the test techniques. Static and dynamic tests were performed to determine the in situ material properties and fundamental frequencies. Damping in the material/ fixture was also found from the dynamic response. These tests were simulated using composite beam theory which gave an analytical solution, andmore » using finite element analysis. The response of the 85% TiB specimens was found to be much more uniform than the functionally graded material and the dynamic response more uniform than the static response. A least squares analysis of the data using the analytical solutions were used to determine the elastic modulus and Poisson's ratio of each layer. These results were used to model the response in the finite element analysis. The results indicate that current analytical and numerical methods for modeling the material give similar and adequate predictions for natural frequencies if the measured property values were used. The models did not agree as well if the properties from the manufacturer or those of Hill and Linn were used.« less

  18. Comparative study of electromechanical impedance and Lamb wave techniques for fatigue crack detection and monitoring in metallic structures

    NASA Astrophysics Data System (ADS)

    Lim, Say Ian; Liu, Yu; Soh, Chee Kiong

    2012-04-01

    Fatigue cracks often initiate at the weld toes of welded steel connections. Usually, these cracks cannot be identified by the naked eyes. Existing identification methods like dye-penetration test and alternating current potential drop (ACPD) may be useful for detecting fatigue cracks at the weld toes. To apply these non-destructive evaluation (NDE) techniques, the potential sites have to be accessible during inspection. Therefore, there is a need to explore other detection and monitoring techniques for fatigue cracks especially when their locations are inaccessible or cost of access is uneconomical. Electro-mechanical Impedance (EMI) and Lamb wave techniques are two fast growing techniques in the Structural Health Monitoring (SHM) community. These techniques use piezoelectric ceramics (PZT) for actuation and sensing. Since the monitoring site is only needed to be accessed once for the instrumentation of the transducers, remote monitoring is made possible. The permanent locations of these transducers also translate to having consistent measurement for monitoring. The main focus of this study is to conduct a comparative investigation on the effectiveness and efficiency of the EMI technique and the Lamb wave technique for successful fatigue crack identification and monitoring of welded steel connections using piezoelectric transducers. A laboratory-sized non-load carrying fillet weld specimen is used in this study. The specimen is subjected to cyclic tensile load and data for both techniques are acquired at stipulated intervals. It can be concluded that the EMI technique is sensitive to the crack initiation phase while the Lamb wave technique correlates well with the crack propagation phase.

  19. The production of calibration specimens for impact testing of subsize Charpy specimens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alexander, D.J.; Corwin, W.R.; Owings, T.D.

    1994-09-01

    Calibration specimens have been manufactured for checking the performance of a pendulum impact testing machine that has been configured for testing subsize specimens, both half-size (5.0 {times} 5.0 {times} 25.4 mm) and third-size (3.33 {times} 3.33 {times} 25.4 mm). Specimens were fabricated from quenched-and-tempered 4340 steel heat treated to produce different microstructures that would result in either high or low absorbed energy levels on testing. A large group of both half- and third-size specimens were tested at {minus}40{degrees}C. The results of the tests were analyzed for average value and standard deviation, and these values were used to establish calibration limitsmore » for the Charpy impact machine when testing subsize specimens. These average values plus or minus two standard deviations were set as the acceptable limits for the average of five tests for calibration of the impact testing machine.« less

  20. On impact damage detection and quantification for CFRP laminates using structural response data only

    NASA Astrophysics Data System (ADS)

    Sultan, M. T. H.; Worden, K.; Pierce, S. G.; Hickey, D.; Staszewski, W. J.; Dulieu-Barton, J. M.; Hodzic, A.

    2011-11-01

    The overall purpose of the research is to detect and attempt to quantify impact damage in structures made from composite materials. A study that uses simplified coupon specimens made from a Carbon Fibre-Reinforced Polymer (CFRP) prepreg with 11, 12 and 13 plies is presented. PZT sensors were placed at three separate locations in each test specimen to record the responses from impact events. To perform damaging impact tests, an instrumented drop-test machine was used and the impact energy was set to cover a range of 0.37-41.72 J. The response signals captured from each sensor were recorded by a data acquisition system for subsequent evaluation. The impacted specimens were examined with an X-ray technique to determine the extent of the damaged areas and it was found that the apparent damaged area grew monotonically with impact energy. A number of simple univariate and multivariate features were extracted from the sensor signals recorded during impact by computing their spectra and calculating frequency centroids. The concept of discordancy from the statistical discipline of outlier analysis is employed in order to separate the responses from non-damaging and damaging impacts. The results show that the potential damage indices introduced here provide a means of identifying damaging impacts from the response data alone.

  1. 10 CFR 26.89 - Preparing to collect specimens for testing.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Preparing to collect specimens for testing. 26.89 Section 26.89 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.89 Preparing to collect specimens for testing. (a) When an individual has been notified of a...

  2. 10 CFR 26.89 - Preparing to collect specimens for testing.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Preparing to collect specimens for testing. 26.89 Section 26.89 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.89 Preparing to collect specimens for testing. (a) When an individual has been notified of a...

  3. 10 CFR 26.89 - Preparing to collect specimens for testing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Preparing to collect specimens for testing. 26.89 Section 26.89 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.89 Preparing to collect specimens for testing. (a) When an individual has been notified of a...

  4. 10 CFR 26.89 - Preparing to collect specimens for testing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Preparing to collect specimens for testing. 26.89 Section 26.89 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.89 Preparing to collect specimens for testing. (a) When an individual has been notified of a...

  5. 10 CFR 26.89 - Preparing to collect specimens for testing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Preparing to collect specimens for testing. 26.89 Section 26.89 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.89 Preparing to collect specimens for testing. (a) When an individual has been notified of a...

  6. Apparatus for Hot Impact Testing of Material Specimens

    NASA Technical Reports Server (NTRS)

    Pawlik, Ralph J.; Choi, Sung R.

    2006-01-01

    An apparatus for positioning and holding material specimens is a major subsystem of a system for impact testing of the specimens at temperatures up to 1,500 C. This apparatus and the rest of the system are designed especially for hot impact testing of advanced ceramics, composites, and coating materials. The apparatus includes a retaining fixture on a rotating stage on a vertically movable cross support driven by a linear actuator. These components are located below a furnace wherein the hot impact tests are performed (see Figure 1). In preparation for a test, a specimen is mounted on the retaining fixture, then the cross support is moved upward to raise the specimen, through an opening in the bottom of the furnace, to the test position inside the furnace. On one side of the furnace there is another, relatively small opening on a direct line to the specimen. Once the specimen has become heated to the test temperature, the test is performed by using an instrumented external pressurized-gas-driven gun to shoot a projectile through the side opening at the specimen.

  7. Urine specimen validity test for drug abuse testing in workplace and court settings.

    PubMed

    Lin, Shin-Yu; Lee, Hei-Hwa; Lee, Jong-Feng; Chen, Bai-Hsiun

    2018-01-01

    In recent decades, urine drug testing in the workplace has become common in many countries in the world. There have been several studies concerning the use of the urine specimen validity test (SVT) for drug abuse testing administered in the workplace. However, very little data exists concerning the urine SVT on drug abuse tests from court specimens, including dilute, substituted, adulterated, and invalid tests. We investigated 21,696 submitted urine drug test samples for SVT from workplace and court settings in southern Taiwan over 5 years. All immunoassay screen-positive urine specimen drug tests were confirmed by gas chromatography/mass spectrometry. We found that the mean 5-year prevalence of tampering (dilute, substituted, or invalid tests) in urine specimens from the workplace and court settings were 1.09% and 3.81%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the workplace were 89.2%, 6.8%, and 4.1%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the court were 94.8%, 1.4%, and 3.8%, respectively. No adulterated cases were found among the workplace or court samples. The most common drug identified from the workplace specimens was amphetamine, followed by opiates. The most common drug identified from the court specimens was ketamine, followed by amphetamine. We suggest that all urine specimens taken for drug testing from both the workplace and court settings need to be tested for validity. Copyright © 2017. Published by Elsevier B.V.

  8. Evaluation of specimen preparation techniques for micro-PIXE localisation of elements in hyperaccumulating plants

    NASA Astrophysics Data System (ADS)

    Kachenko, Anthony G.; Siegele, Rainer; Bhatia, Naveen P.; Singh, Balwant; Ionescu, Mihail

    2008-04-01

    Hybanthus floribundus subsp. floribundus, a rare Australian Ni-hyperaccumulating shrub and Pityrogramma calomelanos var. austroamericana, an Australian naturalized As-hyperaccumulating fern are promising species for use in phytoremediation of contaminated sites. Micro-proton-induced X-ray emission (μ-PIXE) spectroscopy was used to map the elemental distribution of the accumulated metal(loid)s, Ca and K in leaf or pinnule tissues of the two plant species. Samples were prepared by two contrasting specimen preparation techniques: freeze-substitution in tetrahydrofuran (THF) and freeze-drying. The specimens were analysed to compare the suitability of each technique in preserving (i) the spatial elemental distribution and (ii) the tissue structure of the specimens. Further, the μ-PIXE results were compared with concentration of elements in the bulk tissue obtained by ICP-AES analysis. In H. floribundus subsp. floribundus, μ-PIXE analysis revealed Ni, Ca and K concentrations in freeze-dried leaf tissues were at par with bulk tissue concentrations. Elemental distribution maps illustrated that Ni was preferentially localised in the adaxial epidermal tissues (1% DW) and least concentration was found in spongy mesophyll tissues (0.53% DW). Conversely, elemental distribution maps of THF freeze-substituted tissues indicated significantly lower Ni, Ca and K concentrations than freeze-dried specimens and bulk tissue concentrations. Moreover, Ni concentrations were uniform across the whole specimen and no localisation was observed. In P. calomelanos var. austroamericana freeze-dried pinnule tissues, μ-PIXE revealed statistically similar As, Ca and K concentrations as compared to bulk tissue concentrations. Elemental distribution maps showed that As localisation was relatively uniform across the whole specimen. Once again, THF freeze-substituted tissues revealed a significant loss of As compared to freeze-dried specimens and the concentrations obtained by bulk tissue analysis. The results demonstrate that freeze-drying is a suitable sample preparation technique to study elemental distribution of ions in H. floribundus and P. calomelanos plant tissues using μ-PIXE spectroscopy. Furthermore, cellular structure was preserved in samples prepared using this technique.

  9. Characterization of the Edge Crack Torsion (ECT) Test for Mode III Fracture Toughness Measurement of Laminated Composites

    NASA Technical Reports Server (NTRS)

    Ratcliffe, James G.

    2004-01-01

    The edge crack torsion (ECT) test is designed to initiate mode III delamination growth in composite laminates. An ECT specimen is a rectangular laminate, containing an edge delamination at the laminate mid-plane. Torsion load is applied to the specimens, resulting in relative transverse shear sliding of the delaminated faces. The test data reduction schemes are intended to yield initiation values of critical mode III strain energy release rate, G(sub IIIc), that are constant with delamination length. The test has undergone several design changes during its development. The objective of this paper was to determine the suitability of the current ECT test design as a mode III fracture test. To this end, ECT tests were conducted on specimens manufactured from IM7/8552 and specimens made from S2/8552 tape laminates. Several specimens, each with different delamination lengths are tested. Detailed, three-dimensional finite element analyses of the specimens were performed. The analysis results were used to calculate the distribution of mode I, mode II, and mode III strain energy release rate along the delamination front. The results indicated that mode III-dominated delamination growth would be initiated from the specimen center. However, in specimens of both material types, the measured values of G(sub IIIc) exhibited significant dependence on delamination length. Furthermore, there was a large amount of scatter in the data. Load-displacement response of the specimens exhibited significant deviation from linearity before specimen failure. X-radiographs of a sample of specimens revealed that damage was initiated in the specimens prior to failure. Further inspection of the failure surfaces is required to identify the damage and determine that mode III delamination is initiated in the specimens.

  10. Collecting in collections: a PCR strategy and primer set for DNA barcoding of decades-old dried museum specimens.

    PubMed

    Mitchell, Andrew

    2015-09-01

    Natural history museums are vastly underutilized as a source of material for DNA analysis because of perceptions about the limitations of DNA degradation in older specimens. Despite very few exceptions, most DNA barcoding projects, which aim to obtain sequence data from all species, generally use specimens collected specifically for that purpose, instead of the wealth of identified material in museums, constrained by the lack of suitable PCR methods. Any techniques that extend the utility of museum specimens for DNA analysis therefore are highly valuable. This study first tested the effects of specimen age and PCR amplicon size on PCR success rates in pinned insect specimens, then developed a PCR primer set and amplification strategy allowing greatly increased utilization of older museum specimens for DNA barcoding. PCR success rates compare favourably with the few published studies utilizing similar aged specimens, and this new strategy has the advantage of being easily automated for high-throughput laboratory workflows. The strategy uses hemi-nested, degenerate, M13-tailed PCR primers to amplify two overlapping amplicons, using two PCRs per amplicon (i.e. four PCRs per DNA sample). Initial PCR products are reamplified using an internal primer and a M13 primer. Together the two PCR amplicons yield 559 bp of the COI gene from Coleoptera, Lepidoptera, Diptera, Hemiptera, Odonata and presumably also other insects. BARCODE standard-compliant data were recovered from 67% (56 of 84) of specimens up to 25 years old, and 51% (102 of 197) of specimens up to 55 years old. Given the time, cost and specialist expertise required for fieldwork and identification, 'collecting in collections' is a viable alternative allowing researchers to capitalize on the knowledge captured by curation work in decades past. © 2015 John Wiley & Sons Ltd.

  11. Damaged Concrete Viaduct in an Italian Highway: Concrete Characterization and Possible Strengthening Techniques by FRP Applications in Comparison

    NASA Astrophysics Data System (ADS)

    Tittarelli, Francesca; Ruello, Maria Letizia; Capuani, Domenico; Aprile, Alessandra

    2017-10-01

    The “Fornello” viaduct in the Italian Orte-Ravenna highway (E45) is seriously damaged. In this paper, the concrete of the reinforced slab has been widely characterized to evaluate the level of damage and to identify the causes of degradation. No-destructive tests, as those based on ultrasonic waves, as well as chemical, physical and mechanical destructive tests have been carried out on specimens drawn from deteriorated and not deteriorated zones of the R/C bridge decks. Into the slab thickness, the concentration distribution of main anions has been quantified by ion chromatography. Porosimetry tests have been carried out to detect the resistance to freeze-thaw cycles of cement paste. Possible strengthening techniques by FRP applications have been compared.

  12. Simple, direct drug susceptibility testing technique for diagnosis of drug-resistant tuberculosis in resource-poor settings.

    PubMed

    Kim, C-K; Joo, Y-T; Lee, E P; Park, Y K; Kim, H-J; Kim, S J

    2013-09-01

    The Korean Institute of Tuberculosis, Seoul, Republic of Korea. To develop a simple, direct drug susceptibility testing (DST) technique using Kudoh-modified Ogawa (KMO) medium. The critical concentrations of isoniazid (INH), rifampicin (RMP), kanamycin (KM) and ofloxacin (OFX) for KMO medium were calibrated by comparing the minimal inhibitory concentrations (MICs) against clinical isolates of Mycobacterium tuberculosis on KMO with those on Löwenstein-Jensen (LJ). The performance of the direct KMO DST technique was evaluated on 186 smear-positive sputum specimens and compared with indirect LJ DST. Agreement of MICs on direct vs. indirect DST was high for INH, RMP and OFX. KM MICs on KMO were ∼10 g/ml higher than those on LJ. The critical concentrations of INH, RMP, OFX and KM for KMO were therefore set at 0.2, 40.0, 2.0, and 40.0 g/ml. The evaluation of direct DST of smear-positive sputum specimens showed 100% agreement with indirect LJ DST for INH and RMP. However, the respective susceptible and resistant predictive values were 98.8% and 100% for OFX, and 100% and 80% for KM. Direct DST using KMO is useful, with clear advantages of a shorter turnaround time, procedural simplicity and low cost compared to indirect DST. It may be most indicated in resource-poor settings for programmatic management of drug-resistant tuberculosis.

  13. Laser-Stimulated Fluorescence in Paleontology

    PubMed Central

    Kaye, Thomas G.; Falk, Amanda R.; Pittman, Michael; Sereno, Paul C.; Burnham, David A.; Gong, Enpu; Xu, Xing; Wang, Yinan

    2015-01-01

    Fluorescence using ultraviolet (UV) light has seen increased use as a tool in paleontology over the last decade. Laser-stimulated fluorescence (LSF) is a next generation technique that is emerging as a way to fluoresce paleontological specimens that remain dark under typical UV. A laser’s ability to concentrate very high flux rates both at the macroscopic and microscopic levels results in specimens fluorescing in ways a standard UV bulb cannot induce. Presented here are five paleontological case histories that illustrate the technique across a broad range of specimens and scales. Novel uses such as back-lighting opaque specimens to reveal detail and detection of specimens completely obscured by matrix are highlighted in these examples. The recent cost reductions in medium-power short wavelength lasers and use of standard photographic filters has now made this technique widely accessible to researchers. This technology has the potential to automate multiple aspects of paleontology, including preparation and sorting of microfossils. This represents a highly cost-effective way to address paleontology's preparatory bottleneck. PMID:26016843

  14. Axial-Load Fatigue Tests on 17-7 PH Stainless Steel Under Constant-Amplitude Loading

    NASA Technical Reports Server (NTRS)

    Leybold, Herbert A.

    1960-01-01

    Axial-load fatigue tests were conducted at room temperature on notched and unnotched sheet specimens of 17-7 PH stainless steel in Condition TH 1050. The notched specimens had theoretical stress-concentration factors of 2.32, 4.00, and 5.00. All specimens were tested under completely reversed loading. S-N curves are presented for each specimen configuration and ratios of fatigue strengths of unnotched specimens to those of notched specimens are given. Predictions of the fatigue behavior of notched specimens near the fatigue limit were made.

  15. Measurement and Ranking of Permeation Specimen Thickness Profiles: High-Density Polyethylene Swatches

    DTIC Science & Technology

    2016-05-01

    6 3.2 Thickness Comparison between Lube-Cooled and No-Lube Techniques: Non- Welded ...14 3.3 Measured Thickness of Permeation Specimens: Non- Welded ........................16 3.4 Plots of Specimen Measurement Position...versus Thickness ...........................21 3.5 Measured Thickness of Permeation Specimens: Welded ................................23 4

  16. Evaluation of gram-chromotrope kinyoun staining technique: its effectiveness in detecting microsporidial spores in fecal specimens.

    PubMed

    Salleh, Fatmah M; Al-Mekhlafi, Abdulsalam M; Nordin, Anisah; Yasin, 'Azlin M; Al-Mekhlafi, Hesham M; Moktar, Norhayati

    2011-01-01

    This study was conducted to evaluate the modification of the usual Gram-chromotrope staining technique developed in-house known as Gram-chromotrope Kinyoun (GCK) in comparison with the Weber Modified Trichrome (WMT) staining technique; as the reference technique. Two hundred and ninety fecal specimens received by the Microbiology Diagnostic Laboratory of Hospital Universiti Kebangsaan Malaysia were examined for the presence of microsporidial spores. The sensitivity and specificity of GCK compared to the reference technique were 98% and 98.3%, respectively. The positive and negative predictive values were 92.5% and 99.6%, respectively. The agreement between the reference technique and the GCK staining technique was statistically significant by Kappa statistics (K = 0.941, P < 0.001). It is concluded that the GCK staining technique has high sensitivity and specificity in the detection of microsporidial spores in fecal specimens. Hence, it is recommended to be used in the diagnosis of intestinal microsporidiosis. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Design and fabrication of titanium multi-wall Thermal Protection System (TPS) test panels

    NASA Technical Reports Server (NTRS)

    Blair, W.; Meaney, J. E., Jr.; Rosenthal, H. A.

    1980-01-01

    A titanium multiwall thermal protection system panel was designed. The panel is a nine sheet sandwich structure consisting of an upper and lower face sheet; four dimpled sheets, three septum sheets, and clips for attachment to a vehicle structure. An acceptable fabrication process was developed, and the panel design was verified through mechanical and thermal testing of component specimens. A design was completed which takes into consideration fabrication techniques, thermal properties, mechanical properties, and materials availability.

  18. The Effects of Foam Thermal Protection System on the Damage Tolerance Characteristics of Composite Sandwich Structures for Launch Vehicles

    NASA Technical Reports Server (NTRS)

    Nettles, A. T.; Hodge, A. J.; Jackson, J. R.

    2011-01-01

    For any structure composed of laminated composite materials, impact damage is one of the greatest risks and therefore most widely tested responses. Typically, impact damage testing and analysis assumes that a solid object comes into contact with the bare surface of the laminate (the outer ply). However, most launch vehicle structures will have a thermal protection system (TPS) covering the structure for the majority of its life. Thus, the impact response of the material with the TPS covering is the impact scenario of interest. In this study, laminates representative of the composite interstage structure for the Ares I launch vehicle were impact tested with and without the planned TPS covering, which consists of polyurethane foam. Response variables examined include maximum load of impact, damage size as detected by nondestructive evaluation techniques, and damage morphology and compression after impact strength. Results show that there is little difference between TPS covered and bare specimens, except the residual strength data is higher for TPS covered specimens.

  19. Diagnostic Lumbar Puncture

    PubMed Central

    Doherty, Carolynne M; Forbes, Raeburn B

    2014-01-01

    Diagnostic Lumbar Puncture is one of the most commonly performed invasive tests in clinical medicine. Evaluation of an acute headache and investigation of inflammatory or infectious disease of the nervous system are the most common indications. Serious complications are rare, and correct technique will minimise diagnostic error and maximise patient comfort. We review the technique of diagnostic Lumbar Puncture including anatomy, needle selection, needle insertion, measurement of opening pressure, Cerebrospinal Fluid (CSF) specimen handling and after care. We also make some quality improvement suggestions for those designing services incorporating diagnostic Lumbar Puncture. PMID:25075138

  20. Single particle analysis based on Zernike phase contrast transmission electron microscopy.

    PubMed

    Danev, Radostin; Nagayama, Kuniaki

    2008-02-01

    We present the first application of Zernike phase-contrast transmission electron microscopy to single-particle 3D reconstruction of a protein, using GroEL chaperonin as the test specimen. We evaluated the performance of the technique by comparing 3D models derived from Zernike phase contrast imaging, with models from conventional underfocus phase contrast imaging. The same resolution, about 12A, was achieved by both imaging methods. The reconstruction based on Zernike phase contrast data required about 30% fewer particles. The advantages and prospects of each technique are discussed.

  1. On the mechanical characteristics of a self-setting calcium phosphate cement.

    PubMed

    Bimis, A; Canal, L P; Karalekas, D; Botsis, J

    2017-04-01

    To perform a mechanical characterization of a self-setting calcium phosphate cement in function of the immersion time in Ringer solution. Specimens of self-setting calcium phosphate cement were prepared from pure α-TCP powder. The residual strains developed during hardening stage were monitored using an embedded fiber Bragg grating sensor. Additionally, the evolution of the elastic modulus was obtained for the same time period by conducting low-load indentation tests. Micro-computed tomography as well as microscope-assisted inspections were employed to evaluate the porosity in the specimens. Moreover, diametral compression tests were conducted in wet and dried specimens to characterize the material strength. The volume of the estimated porosity and absorbed fluid mass, during the first few minutes of the material's exposure in a wet environment, coincide. The immersion in Ringer solution lead to a noticeable increase in the moduli values. The critical value of stresses obtained from the diametral compression tests were combined with the data from uniaxial compression tests, to suggest a Mohr-Coulomb failure criterion. This study presents different techniques to characterize a self-setting calcium phosphate cement and provides experimental data on porosity, mechanical properties and failure. The investigated material possessed an open porosity at its dried state with negligible residual strains and its Young's modulus, obtained from micro-indentation tests, increased with hardening time. The failure loci may be described by a Mohr-Coulomb criterion, characteristic of soil and rock materials. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Slow Crack Growth Behavior and Life/Reliability Analysis of 96 wt % Alumina at Ambient Temperature With Various Specimen/Loading Configurations

    NASA Technical Reports Server (NTRS)

    Choi, Sung R.; Powers, Lynn M.; Nemeth, Noel N.

    2000-01-01

    Extensive constant stress-rate testing for 96 wt % alumina was conducted in room-temperature distilled water using four different specimen/loading configurations: rectangular beam test specimens under four-point uniaxial flexure, square plate test specimens in ring-on-ring biaxial flexure, square plate test specimens in ball-on-ring biaxial flexure, and dog-boned tensile test specimens in pure tension. The slow crack growth (SCG) parameter n was almost independent of specimen/loading configurations, in either four-point uniaxial flexure, ring-on-ring biaxial flexure, ball-on-ring biaxial flexure, or pure tension, ranging from n = 35 to 47 with an average value of n = 41.1 +/- 4.5. The prediction of fatigue strength/reliability based on the four-point uniaxial flexure data by using the CARES/Life design code as well as a simple PIA model was in good agreement with both the ring-on-ring biaxial and the ball-on-ring biaxial flexure data. A poor prediction using the PIA model was observed for the dog-boned tensile test specimens, presumably due to different flaw population involved in the tensile test specimens.

  3. Testing compression strength of wood logs by drilling resistance

    NASA Astrophysics Data System (ADS)

    Kalny, Gerda; Rados, Kristijan; Rauch, Hans Peter

    2017-04-01

    Soil bioengineering is a construction technique using biological components for hydraulic and civil engineering solutions, based on the application of living plants and other auxiliary materials including among others log wood. Considering the reliability of the construction it is important to know about the durability and the degradation process of the wooden logs to estimate and retain the integral performance of a soil bioengineering system. An important performance indicator is the compression strength, but this parameter is not easy to examine by non-destructive methods. The Rinntech Resistograph is an instrument to measure the drilling resistance by a 3 mm wide needle in a wooden log. It is a quasi-non-destructive method as the remaining hole has no weakening effects to the wood. This is an easy procedure but result in values, hard to interpret. To assign drilling resistance values to specific compression strengths, wooden specimens were tested in an experiment and analysed with the Resistograph. Afterwards compression tests were done at the same specimens. This should allow an easier interpretation of drilling resistance curves in future. For detailed analyses specimens were investigated by means of branch inclusions, cracks and distances between annual rings. Wood specimens are tested perpendicular to the grain. First results show a correlation between drilling resistance and compression strength by using the mean drilling resistance, average width of the annual rings and the mean range of the minima and maxima values as factors for the drilling resistance. The extended limit of proportionality, the offset yield strength and the maximum strength were taken as parameters for compression strength. Further investigations at a second point in time strengthen these results.

  4. Application of a Novel DCPD Adjustment Method for the J-R Curve Characterization: A study based on ORNL and ASTM Interlaboratory Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Xiang; Sokolov, Mikhail A; Nanstad, Randy K

    Material fracture toughness in the fully ductile region can be described by a J-integral vs. crack growth resistance curve (J-R curve). As a conventional J-R curve measurement method, the elastic unloading compliance (EUC) method becomes impractical for elevated temperature testing due to relaxation of the material and friction induced back-up shape of the J-R curve. One alternative solution of J-R curve testing applies the Direct Current Potential Drop (DCPD) technique for measuring crack extension. However, besides crack growth, potential drop can also be influenced by plastic deformation, crack tip blunting, etc., and uncertainties exist in the current DCPD methodology especiallymore » in differentiating potential drop due to stable crack growth and due to material deformation. Thus, using DCPD for J-R curve determination remains a challenging task. In this study, a new adjustment procedure for applying DCPD to derive the J-R curve has been developed for conventional fracture toughness specimens, including compact tension, three-point bend, and disk-shaped compact specimens. Data analysis has been performed on Oak Ridge National Laboratory (ORNL) and American Society for Testing and Materials (ASTM) interlaboratory results covering different specimen thicknesses, test temperatures, and materials, to evaluate the applicability of the new DCPD adjustment procedure for J-R curve characterization. After applying the newly-developed procedure, direct comparison between the DCPD method and the normalization method on the same specimens indicated close agreement for the overall J-R curves, as well as the provisional values of fracture toughness near the onset of ductile crack extension, Jq, and of tearing modulus.« less

  5. Assessment of Composite Delamination Self-Healing Via Micro-Encapsulation

    NASA Technical Reports Server (NTRS)

    O'Brien, T. Kevin; White, Scott R.

    2008-01-01

    Composite skin/stringer flange debond specimens manufactured from composite prepreg containing interleaf layers with a polymer based healing agent encapsulated in thin walled spheres were tested. As a crack develops and grows in the base polymer, the spheres fracture releasing the healing agent. The agent reacts with catalyst and polymerizes healing the crack. In addition, through-thickness reinforcement, in the form of pultruded carbon z-pins were included near the flange tips to improve the resistance to debonding. Specimens were manufactured with 14 plies in the skin and 10 plies in the stiffener flange. Three-point bend tests were performed to measure the skin/stiffener debonding strength and the recovered strength after healing. The first three tests performed indicated no healing following unloading and reloading. Micrographs showed that delaminations could migrate to the top of the interleaf layer due to the asymmetric loading, and hence, bypass most of the embedded capsules. For two subsequent tests, specimens were clamped in reverse bending before reloading. In one case, healing was observed as evidenced by healing agent that leaked to the specimen edge forming a visible "scar". The residual strength measured upon reloading was 96% of the original strength indicating healing had occurred. Hence, self-healing is possible in fiber reinforced composite material under controlled conditions, i.e., given enough time and contact with pressure on the crack surfaces. The micro-encapsulation technique may prove more robust when capsule sizes can be produced that are small enough to be embedded in the matrix resin without the need for using an interleaf layer. However, in either configuration, the amount of healing that can occur may be limited to the volume of healing agent available relative to the crack volume that must be filled.

  6. Detection of mycobacterium tuberculosis in paraffin-embedded pleural biopsy specimens by commercial ribosomal RNA and DNA amplification kits.

    PubMed

    Ruiz-Manzano, J; Manterola, J M; Gamboa, F; Calatrava, A; Monsó, E; Martínez, C; Ausina, V

    2000-09-01

    To evaluate the utility of two gene amplification systems in historical paraffin-embedded pleural biopsy (PEB) tissues from patients with pleural tuberculosis, and to compare the results to those obtained with conventional histologic and microbiological methods. A retrospective study. Seventy-four formalin-fixed PEB tissues collected and stored over 12 years (1984 through 1995) were retrieved. Gene amplifications were performed in 57 tissues from patients with diagnoses of pleural tuberculosis and in 17 from patients with carcinoma as controls, using the first version of the Amplified Mycobacterium tuberculosis Direct Test (AMTDT; Gen-Probe; San Diego, CA) and the LCx Mycobacterium tuberculosis Assay (LCxMTB; Abbott Laboratories; Abbott Park, IL). The sensitivities of the AMTDT and LCxMTB were 52.6% and 63.2%, respectively (p = not statistically significant). The specificity of both tests was 100%. Twenty tissue samples (35.1%) were positive by both systems, and 10 tissues (17.5%) were positive only by the AMTDT, while 16 tissues (28.1%) were positive only by the LCxMTB. Both tests gave negative results for 11 specimens (19.3%). When both tests were used, a positive diagnosis was achieved in 80.7% of the samples. Diagnosis of 73.7% of patient conditions had previously been made by smear examination of pleural biopsy and sputum, pleural liquid, or biopsy culture. The overall diagnostic yield with both culture and amplification techniques was 96.5% (55 of 57 patients) for pleural tuberculosis, with amplification techniques adding 22.8% of the diagnoses. Amplification techniques are useful in archival PEB tissues, providing additional diagnoses beyond culturing, although the sensitivity should be improved, possibly by standardizing protocols.

  7. 49 CFR 40.171 - How does an employee request a test of a split specimen?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false How does an employee request a test of a split specimen? 40.171 Section 40.171 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Split Specimen Tests § 40.171 How does an employee request a test of a split specimen? (a...

  8. Determination of the gaseous hydrogen ductile-brittle transition in copper-nickel alloys

    NASA Technical Reports Server (NTRS)

    Parr, R. A.; Johnston, M. H.; Davis, J. H.; Oh, T. K.

    1985-01-01

    A series of copper-nickel alloys were fabricated, notched tensile specimens machined for each alloy, and the specimens tested in 34.5 MPa hydrogen and in air. A notched tensile ratio was determined for each alloy and the hydrogen environment embrittlement (HEE) determined for the alloys of 47.7 weight percent nickel to 73.5 weight percent nickel. Stacking fault probability and stacking fault energies were determined for each alloy using the x ray diffraction line shift and line profiles technique. Hydrogen environment embrittlement was determined to be influenced by stacking fault energies; however, the correlation is believed to be indirect and only partially responsible for the HEE behavior of these alloys.

  9. Anaerobic Bacteria in Clinical Specimens – Frequent, But a Neglected Lot: A Five Year Experience at a Tertiary Care Hospital

    PubMed Central

    Shenoy, Padmaja Ananth; Gawda, Ashwini; Shetty, Seema; Anegundi, Renuka; Varma, Muralidhar; Mukhopadhyay, Chiranjay; Chawla, Kiran

    2017-01-01

    Introduction Anaerobic bacteria which constitute a significant proportion of the normal microbiota also cause variety of infections involving various anatomic sites. Considering the tedious culture techniques with longer turnaround time, anaerobic cultures are usually neglected by clinicians and microbiologists. Aim To study the frequency of isolation of different anaerobic bacteria from various clinical specimens. Materials and Methods A retrospective study to analyse the frequency of isolation of different anaerobic bacteria, was conducted over a period of five years from 2011 to 2015 including various clinical specimens submitted to anaerobic division of Microbiology laboratory. Anaerobic bacteria were isolated and identified following standard bacteriological techniques. Results Pathogenic anaerobes (n=336) were isolated from 278 (12.48%) of overall 2227 specimens processed with an average yield of 1.2 isolates. Anaerobes were isolated as polymicrobial flora with or without aerobic bacterial pathogens in 159 (57.2%) patients. Anaerobic Gram-negative bacilli (140, 41.7%) were the predominant isolates. B. fragilis group (67, 19.9%) were the most commonly isolated anaerobic pathogens. Anaerobes were predominantly isolated from deep seated abscess (23.9%). Conclusion Pathogenic anaerobes were isolated from various infection sites. Unless culture and susceptibility tests are performed as a routine, true magnitude of antimicrobial resistance among anaerobic pathogens will not be known. Knowledge of the distribution of these organisms may assist in the selection of appropriate empirical therapy for anaerobic infections. PMID:28892897

  10. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  11. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  12. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  13. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  14. 10 CFR 26.95 - Conducting an initial test for alcohol using a breath specimen.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Conducting an initial test for alcohol using a breath specimen. 26.95 Section 26.95 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.95 Conducting an initial test for alcohol using a breath specimen. (a) The...

  15. Effects of long duration exposure to simulated space environment on nonmetallic materials properties

    NASA Technical Reports Server (NTRS)

    Peacock, C. L., Jr.; Whitaker, A. F.

    1983-01-01

    Nonmetallic materials specimens from the Viking program were tested in situ invacuo after continuous thermal vacuum exposure from 1971/1972 to the present. Eleven tests were done on appropriate specimens of 30 materials; however, no single material received all the tests. Some specimens also were exposed to 1 or 2.5 MeV electrons at differing fluences before testing. Baseline exposure data is reported for graphite/epoxy specimens that were exposed to vacuum since 1974. These materials were transferred to the thermal vacuum storage facility for future in situ testing and irradiation. Thin G/E specimens were tensile tested after thermal-vacuum cycling exposure. Photomicrographic examinations and SEM analyses were done on the failed specimens.

  16. Eutectic Experiment Development for Space Processing

    NASA Technical Reports Server (NTRS)

    Hopkins, R. H.

    1972-01-01

    A ground base test plan and a specimen evaluation scheme have been developed for the aluminum-copper eutectic solidification experiment to be run in the M518 multipurpose electric furnace during the Skylab mission. Besides thermal and solidification studies a detailed description is given of the quantitative metallographic technique which is appropriate for characterizing eutectic structures. This method should prove a key tool for evaluating specimen microstructure which is the most sensitive indicator of changes produced during solidification. It has been recommended that single grain pre-frozen eutectic specimens be used to simplify microstructural evaluation and to eliminate any porosity in the as-cast eutectic specimens. High purity (99.999%) materials from one supplier should be employed for all experiments. Laboratory studies indicate that porosity occurs in the MRC as-cast eutectic ingots but that this porosity can be eliminated by directional freezing. Chemical analysis shows that the MRC ingots are slightly Al rich and contain about .03% impurity. Because of the impurity content the lower cooldown rate (1.2 C/min) should be used for eutectic freezing if MRC material is used in the M518 furnace.

  17. Nondestructive Evaluation of Adhesively Bonded Joints

    NASA Technical Reports Server (NTRS)

    Nayeb-Hashemi, Hamid; Rossettos, J. N.

    1997-01-01

    The final report consists of 5 published papers in referred journals and a technical letter to the technical monitor. These papers include the following: (1) Comparison of the effects of debonds and voids in adhesive; (2) On the peak shear stresses in adhesive joints with voids; (3) Nondestructive evaluation of adhesively bonded joints by acousto-ultrasonic technique and acoustic emission; (4) Multiaxial fatigue life evaluation of tubular adhesively bonded joints; (5) Theoretical and experimental evaluation of the bond strength under peeling loads. The letter outlines the progress of the research. Also included is preliminary information on the study of nondestructive evaluation of composite materials subjected to localized heat damage. The investigators studied the effects of localized heat on unidirectional fiber glass epoxy composite panels. Specimens of the fiber glass epoxy composites were subjected to 400 C heat for varying lengths of time. The specimens were subjected to nondestructive tests. The specimens were then pulled to their failure and acoustic emission of these specimens were measured. The analysis of the data was continuing as of the writing of the letter, and includes a finite element stress analysis of the problem.

  18. 3D-Printed specimens as a valuable tool in anatomy education: A pilot study.

    PubMed

    Garas, Monique; Vaccarezza, Mauro; Newland, George; McVay-Doornbusch, Kylie; Hasani, Jamila

    2018-06-06

    Three-dimensional (3D) printing is a modern technique of creating 3D-printed models that allows reproduction of human structures from MRI and CT scans via fusion of multiple layers of resin materials. To assess feasibility of this innovative resource as anatomy educational tool, we conducted a preliminary study on Curtin University undergraduate students to investigate the use of 3D models for anatomy learning as a main goal, to assess the effectiveness of different specimen types during the sessions and personally preferred anatomy learning tools among students as secondary aim. The study consisted of a pre-test, exposure to test (anatomical test) and post-test survey. During pre-test, all participants (both without prior experience and experienced groups) were given a brief introduction on laboratory safety and study procedure thus participants were exposed to 3D, wet and plastinated specimens of the heart, shoulder and thigh to identify the pinned structures (anatomical test). Then, participants were provided a post-test survey containing five questions. In total, 23 participants completed the anatomical test and post-test survey. A larger number of participants (85%) achieved right answers for 3D models compared to wet and plastinated materials, 74% of population selected 3D models as the most usable tool for identification of pinned structures and 45% chose 3D models as their preferred method of anatomy learning. This preliminary small-size study affirms the feasibility of 3D-printed models as a valuable asset in anatomy learning and shows their capability to be used adjacent to cadaveric materials and other widely used tools in anatomy education. Copyright © 2018 Elsevier GmbH. All rights reserved.

  19. Fatigue Damage Assessment Leveraging Nondestructive Evaluation Data

    NASA Astrophysics Data System (ADS)

    Mazur, K.; Wisner, B.; Kontsos, A.

    2018-05-01

    Fatigue in materials depends on several microstructural parameters. The length and time scales involved in such processes have been investigated by characterization methods that target microstructural effects or that rely on specimen-level observations. Combinations of in situ and ex situ techniques are also used to correlate microstructural changes to bulk properties. We present herein an effort to directly link local changes with specimen-level fatigue damage assessment. To achieve this goal, grain-scale observations in an aluminum alloy are linked with deformation measurements made by digital image correlation and with acoustic emission monitoring obtained from inside the scanning electron microscope. Damage assessment is attempted using a data-processing framework that involves noise removal, data reduction, and classification. The results demonstrate that nondestructive evaluation combined with small-scale testing can provide a means for fatigue damage assessment applicable to a broad range of materials and testing conditions.

  20. A study on the crushing behavior of basalt fiber reinforced composite structures

    NASA Astrophysics Data System (ADS)

    Pandian, A.; Veerasimman, A. P.; Vairavan, M.; Francisco, C.; Sultan, M. T. H.

    2016-10-01

    The crushing behavior and energy absorption capacity of basalt fiber reinforced hollow square structure composites are studied under axial compression. Using the hand layup technique, basalt fiber reinforced composites were fabricated using general purpose (GP) polyester resin with the help of wooden square shaped mould of varying height (100 mm, 150 mm and 200 mm). For comparison, similar specimens of glass fiber reinforced polymer composites were also fabricated and tested. Axial compression load is applied over the top end of the specimen with cross head speed as 2 mm/min using Universal Testing Machine (UTM). From the experimental results, the load-deformation characteristics of both glass fiber and basalt fiber composites were investigated. Crashworthiness and mode of collapse for the composites were determined from load-deformation curve, and they were then compared to each other in terms of their crushing behaviors.