Sample records for specimens statistical analyses

  1. The analysis of morphometric data on rocky mountain wolves and artic wolves using statistical method

    NASA Astrophysics Data System (ADS)

    Ammar Shafi, Muhammad; Saifullah Rusiman, Mohd; Hamzah, Nor Shamsidah Amir; Nor, Maria Elena; Ahmad, Noor’ani; Azia Hazida Mohamad Azmi, Nur; Latip, Muhammad Faez Ab; Hilmi Azman, Ahmad

    2018-04-01

    Morphometrics is a quantitative analysis depending on the shape and size of several specimens. Morphometric quantitative analyses are commonly used to analyse fossil record, shape and size of specimens and others. The aim of the study is to find the differences between rocky mountain wolves and arctic wolves based on gender. The sample utilised secondary data which included seven variables as independent variables and two dependent variables. Statistical modelling was used in the analysis such was the analysis of variance (ANOVA) and multivariate analysis of variance (MANOVA). The results showed there exist differentiating results between arctic wolves and rocky mountain wolves based on independent factors and gender.

  2. Impact of specimen adequacy on the assessment of renal allograft biopsy specimens.

    PubMed

    Cimen, S; Geldenhuys, L; Guler, S; Imamoglu, A; Molinari, M

    2016-01-01

    The Banff classification was introduced to achieve uniformity in the assessment of renal allograft biopsies. The primary aim of this study was to evaluate the impact of specimen adequacy on the Banff classification. All renal allograft biopsies obtained between July 2010 and June 2012 for suspicion of acute rejection were included. Pre-biopsy clinical data on suspected diagnosis and time from renal transplantation were provided to a nephropathologist who was blinded to the original pathological report. Second pathological readings were compared with the original to assess agreement stratified by specimen adequacy. Cohen's kappa test and Fisher's exact test were used for statistical analyses. Forty-nine specimens were reviewed. Among these specimens, 81.6% were classified as adequate, 6.12% as minimal, and 12.24% as unsatisfactory. The agreement analysis among the first and second readings revealed a kappa value of 0.97. Full agreement between readings was found in 75% of the adequate specimens, 66.7 and 50% for minimal and unsatisfactory specimens, respectively. There was no agreement between readings in 5% of the adequate specimens and 16.7% of the unsatisfactory specimens. For the entire sample full agreement was found in 71.4%, partial agreement in 20.4% and no agreement in 8.2% of the specimens. Statistical analysis using Fisher's exact test yielded a P value above 0.25 showing that - probably due to small sample size - the results were not statistically significant. Specimen adequacy may be a determinant of a diagnostic agreement in renal allograft specimen assessment. While additional studies including larger case numbers are required to further delineate the impact of specimen adequacy on the reliability of histopathological assessments, specimen quality must be considered during clinical decision making while dealing with biopsy reports based on minimal or unsatisfactory specimens.

  3. Contact thermal shock test of ceramics

    NASA Technical Reports Server (NTRS)

    Rogers, W. P.; Emery, A. F.

    1992-01-01

    A novel quantitative thermal shock test of ceramics is described. The technique employs contact between a metal-cooling rod and hot disk-shaped specimen. In contrast with traditional techniques, the well-defined thermal boundary condition allows for accurate analyses of heat transfer, stress, and fracture. Uniform equibiaxial tensile stresses are induced in the center of the test specimen. Transient specimen temperature and acoustic emission are monitored continuously during the thermal stress cycle. The technique is demonstrated with soda-lime glass specimens. Experimental results are compared with theoretical predictions based on a finite-element method thermal stress analysis combined with a statistical model of fracture. Material strength parameters are determined using concentric ring flexure tests. Good agreement is found between experimental results and theoretical predictions of failure probability as a function of time and initial specimen temperature.

  4. Dicalcium phosphate (CaHPO4·2H2O) precipitation through ortho- or meta-phosphoric acid-etching: effects on the durability and nanoleakage/ultra-morphology of resin-dentine interfaces.

    PubMed

    Feitosa, Victor Pinheiro; Bazzocchi, Maria Giulia; Putignano, Angelo; Orsini, Giovanna; Luzi, Arlinda Luzi; Sinhoreti, Mário Alexandre Coelho; Watson, Timothy F; Sauro, Salvatore

    2013-11-01

    To compare the effects of two etching procedures using meta-phosphoric (MPA) or ortho-phosphoric acid (OPA) on dentine demineralisation, resin-dentine bonds durability and interface nanoleakage/ultra-morphology. Middle-dentine specimens were etched using 37% OPA (15s) or 40% MPA (60s) and submitted to infrared spectroscopy (FTIR) or ultra-morphology dye-assisted (calcium-staining) confocal microscopy (Ca-CLSM). A three-step etch-and-rinse adhesive was formulated, applied onto dentine and light-cured for 30s before composite build-up. After 24h, the dentine-bonded specimens were cut into 1mm(2) beams; half were immediately submitted to microtensile bond strength (μTBS) and half stored in DW for six months. The μTBS results were analysed with repeated-measures ANOVA and Tukey's test (p<0.05). Further teeth were bonded and prepared for interface nanoleakage/ultra-morphology confocal evaluation. FTIR and Ca-CLSM analyses showed dicalcium phosphate dihydrate (Brushite) precipitation in MPA-etched dentine and on the bottom (front of demineralisation) of the OPA-etched dentine. Statistical analysis showed similar μTBS for both etching procedures after 24h. The μTBS of specimens in OPA-group dropped significantly (p<0.05) after six month; the specimens in the MPA group showed no statistically difference (p>0.05). CLSM depicted no evident sign of nanoleakage within the resin-dentine interface of the MPA-treated specimens, while the specimens in OPA-group presented intense nanoleakage and interface degradation. The use of MPA (60s) as an alternative dentine conditioning agent in etch-and-rinse bonding procedures may be a suitable strategy to create more durable resin-dentine bonds. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Statistical Analyses for Probabilistic Assessments of the Reactor Pressure Vessel Structural Integrity: Building a Master Curve on an Extract of the 'Euro' Fracture Toughness Dataset, Controlling Statistical Uncertainty for Both Mono-Temperature and multi-temperature tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Josse, Florent; Lefebvre, Yannick; Todeschini, Patrick

    2006-07-01

    Assessing the structural integrity of a nuclear Reactor Pressure Vessel (RPV) subjected to pressurized-thermal-shock (PTS) transients is extremely important to safety. In addition to conventional deterministic calculations to confirm RPV integrity, Electricite de France (EDF) carries out probabilistic analyses. Probabilistic analyses are interesting because some key variables, albeit conventionally taken at conservative values, can be modeled more accurately through statistical variability. One variable which significantly affects RPV structural integrity assessment is cleavage fracture initiation toughness. The reference fracture toughness method currently in use at EDF is the RCCM and ASME Code lower-bound K{sub IC} based on the indexing parameter RT{submore » NDT}. However, in order to quantify the toughness scatter for probabilistic analyses, the master curve method is being analyzed at present. Furthermore, the master curve method is a direct means of evaluating fracture toughness based on K{sub JC} data. In the framework of the master curve investigation undertaken by EDF, this article deals with the following two statistical items: building a master curve from an extract of a fracture toughness dataset (from the European project 'Unified Reference Fracture Toughness Design curves for RPV Steels') and controlling statistical uncertainty for both mono-temperature and multi-temperature tests. Concerning the first point, master curve temperature dependence is empirical in nature. To determine the 'original' master curve, Wallin postulated that a unified description of fracture toughness temperature dependence for ferritic steels is possible, and used a large number of data corresponding to nuclear-grade pressure vessel steels and welds. Our working hypothesis is that some ferritic steels may behave in slightly different ways. Therefore we focused exclusively on the basic french reactor vessel metal of types A508 Class 3 and A 533 grade B Class 1, taking the sampling level and direction into account as well as the test specimen type. As for the second point, the emphasis is placed on the uncertainties in applying the master curve approach. For a toughness dataset based on different specimens of a single product, application of the master curve methodology requires the statistical estimation of one parameter: the reference temperature T{sub 0}. Because of the limited number of specimens, estimation of this temperature is uncertain. The ASTM standard provides a rough evaluation of this statistical uncertainty through an approximate confidence interval. In this paper, a thorough study is carried out to build more meaningful confidence intervals (for both mono-temperature and multi-temperature tests). These results ensure better control over uncertainty, and allow rigorous analysis of the impact of its influencing factors: the number of specimens and the temperatures at which they have been tested. (authors)« less

  6. Comparative Evaluation of Marginal Discrepancy in Tooth Colored Self Cure Acrylic Provisional Restorations With and Without Reinforcement of Glass Beads: An In-Vitro Study.

    PubMed

    Yasangi, Manoj Kumar; Mannem, Dhanalakshmi; Bommireddy, Vikram Simha; Neturi, Sirisha; Ravoori, Srinivas; Jyothi

    2015-05-01

    This invitro study was conducted to compare and evaluate marginal discrepancy in two types of tooth colored self cure provisional restorative materials {DPI&UNIFAST TRAD} before and after reinforcement of glass beads. The aim of the present study was to evaluate and compare marginal discrepancy in two types of provisional restorative materials (DPI and UNI FAST TRAD) before and after reinforcement with Glass beads. Tooth shaped resin copings were fabricated on custom made brass metal die. A total of 60 resin copings were fabricated in which 30 samples were prepared with DPI and 30 samples with UNIFAST material. Each group of 30 samples were divided in to two sub groups in which 15 samples were prepared with glass bead reinforcement and 15 samples without reinforcement. The marginal discrepancy was evaluated with photomicroscope {Reichet Polyvar 2 met} by placing the resin copings on custom made brass resin coping holder. Measurements obtained were statistically analysed by unpaired t-test to know any significance between two variables. Unreinforced DPI specimens had shown lower marginal discrepancy (442.82) than reinforced specimens (585.77). Unreinforced UNIFAST specimens have shown high values of marginal discrepancy (592.83) than reinforced specimens (436.35). p-value between reinforced and unreinforced specimens of DPI (p=0.0013) and UNIFAST (p= 0.0038) has shown statistical significance. This in-vitro study revealed that unreinforced DPI specimens have shown lower marginal discrepancy than reinforced specimens and unreinforced UNIFAST specimens have shown higher values of marginal discrepancy than reinforced specimens.

  7. Effect of Different Anti-Oxidants on Shear Bond Strength of Composite Resins to Bleached Human Enamel

    PubMed Central

    Saladi, Hari Krishna; Bollu, Indira Priyadarshini; Burla, Devipriya; Ballullaya, Srinidhi Vishnu; Devalla, Srihari; Maroli, Sohani; Jayaprakash, Thumu

    2015-01-01

    Introduction The bond strength of the composite to the bleached enamel plays a very important role in the success and longevity of an aesthetic restoration. Aim The aim of this study was to compare and evaluate the effect of Aloe Vera with 10% Sodium Ascorbate on the Shear bond strength of composite resin to bleached human enamel. Materials and Methods Fifty freshly extracted human maxillary central incisors were selected and divided into 5 groups. Group I and V are unbleached and bleached controls groups respectively. Group II, III, IV served as experimental groups. The labial surfaces of groups II, III, IV, V were treated with 35% Carbamide Peroxide for 30mins. Group II specimens were subjected to delayed composite bonding. Group III and IV specimens were subjected to application of 10% Sodium Ascorbate and leaf extract of Aloe Vera following the Carbamide Peroxide bleaching respectively. Specimens were subjected to shear bond strength using universal testing machine and the results were statistically analysed using ANOVA test. Tukey (HSD) Honest Significant Difference test was used to comparatively analyse statistical differences between the groups. A p-value <0.05 is taken as statistically significant. Results The mean shear bond strength values of Group V showed significantly lower bond strengths than Groups I, II, III, IV (p-value <0.05). There was no statistically significant difference between the shear bond strength values of groups I, II, III, IV. Conclusion Treatment of the bleached enamel surface with Aloe Vera and 10% Sodium Ascorbate provided consistently better bond strength. Aloe Vera may be used as an alternative to 10% Sodium Ascorbate. PMID:26674656

  8. Effect of Airborne Particle Abrasion on Microtensile Bond Strength of Total-Etch Adhesives to Human Dentin

    PubMed Central

    Piccioni, Chiara; Di Carlo, Stefano; Capogreco, Mario

    2017-01-01

    Aim of this study was to investigate a specific airborne particle abrasion pretreatment on dentin and its effects on microtensile bond strengths of four commercial total-etch adhesives. Midcoronal occlusal dentin of extracted human molars was used. Teeth were randomly assigned to 4 groups according to the adhesive system used: OptiBond FL (FL), OptiBond Solo Plus (SO), Prime & Bond (PB), and Riva Bond LC (RB). Specimens from each group were further divided into two subgroups: control specimens were treated with adhesive procedures; abraded specimens were pretreated with airborne particle abrasion using 50 μm Al2O3 before adhesion. After bonding procedures, composite crowns were incrementally built up. Specimens were sectioned perpendicular to adhesive interface to produce multiple beams, which were tested under tension until failure. Data were statistically analysed. Failure mode analysis was performed. Overall comparison showed significant increase in bond strength (p < 0.001) between abraded and no-abraded specimens, independently of brand. Intrabrand comparison showed statistical increase when abraded specimens were tested compared to no-abraded ones, with the exception of PB that did not show such difference. Distribution of failure mode was relatively uniform among all subgroups. Surface treatment by airborne particle abrasion with Al2O3 particles can increase the bond strength of total-etch adhesives. PMID:29392128

  9. Contamination of different portions of raw and boiled specimens of Norway lobster by mercury and selenium.

    PubMed

    Perugini, Monia; Visciano, Pierina; Manera, Maurizio; Abete, Maria Cesarina; Gavinelli, Stefania; Amorena, Michele

    2013-11-01

    The aim of this study was to evaluate mercury and selenium distribution in different portions (exoskeleton, white meat and brown meat) of Norway lobster (Nephrops norvegicus). Some samples were also analysed as whole specimens. The same portions were also examined after boiling, in order to observe if this cooking practice could affect mercury and selenium concentrations. The highest mercury concentrations were detected in white meat, exceeding in all cases the maximum levels established by European legislation. The brown meat reported the highest selenium concentrations. In all boiled samples, mercury levels showed a statistically significant increase compared to raw portions. On the contrary, selenium concentrations detected in boiled samples of white meat, brown meat and whole specimen showed a statistically significant decrease compared to the corresponding raw samples. These results indicate that boiling modifies mercury and selenium concentrations. The high mercury levels detected represent a possible risk for consumers, and the publication and diffusion of specific advisories concerning seafood consumption is recommended.

  10. Effect of tulle on the mechanical properties of a maxillofacial silicone elastomer.

    PubMed

    Gunay, Yumushan; Kurtoglu, Cem; Atay, Arzu; Karayazgan, Banu; Gurbuz, Cihan Cem

    2008-11-01

    The purpose of this research was to investigate if physical properties could be improved by incorporating a tulle reinforcement material into a maxillofacial silicone elastomer. A-2186 silicone elastomer was used in this study. The study group consisted of 20 elastomer specimens incorporated with tulle and fabricated in dumbbell-shaped silicone patterns using ASTM D412 and D624 standards. The control group consisted of 20 elastomer specimens fabricated without tulle. Tensile strength, ultimate elongation, and tear strength of all specimens were measured and analyzed. Statistical analyses were performed using Mann-Whitney U test with a statistical significance at 95% confidence level. It was found that the tensile and tear strengths of tulle-incorporated maxillofacial silicone elastomer were higher than those without tulle incorporation (p < 0.05). Therefore, findings of this study suggested that tulle successfully reinforced a maxillofacial silicone elastomer by providing it with better mechanical properties and augmented strength--especially for the delicate edges of maxillofacial prostheses.

  11. Evaluation to determine the caries remineralization potential of three dentifrices: An in vitro study

    PubMed Central

    Balakrishnan, Arun; Jonathan, R; Benin, P; Kuumar, Arvind

    2013-01-01

    Aim: The aim of this study was to evaluate the remineralizing potential of three different remineralizing agents (GC tooth Mousse, Clinpro tooth crθme and SHY-NM) on demineralized tooth surfaces using micro CT and microhardness. Materials and Methods: Forty five freshly extracted mandibular premolars were collected and enamel specimens were prepared. The samples were assigned to three groups with fifteen specimens in each group. The specimens were then demineralized using McInne's demineralizing solution in two cycles. After that, remineralization was carried out in two cycles for 30 days using Casein phosphopeptide - Amorphous calcium phosphate (CPP - ACP), 0.21% sodium fluoride - Tricalcium phosphate (f-TCP) and Calcium Sodium Phosphosilicate (CSP) containing tooth pastes for groups I, II, III respectively. The specimens were evaluated for Linear attenuation co-efficient using micro CT (Scanco™) and Vicker's Micro Hardness (Schimadzu™) testing at different time periods. The results were tabulated and statistically analysed. Results: It was observed that all the three remineralizing agents used in the study significantly increased the Linear Attenuation Co-efficient and Vicker's hardness number values of the enamel specimens following 15 days and 30 days application. Conclusion: CPP – ACP showed the better remineralizing potential than the other two agents and there was no statistical significant difference between f-TCP and CSP groups. PMID:23956545

  12. Interrelationship of mechanical and corrosion-mechanical characteristics of type 12KhN4MF steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Voronin, V.P.; Goncharov, A.F.; Maslov, V.A.

    1985-11-01

    Investigations presented include a comparative evaluation of the corrosionmechanical characteristics of specimens of high-strength chrome-nickelmolybdenum steel taking into consideration the different methods of melting of the original metal. A comparison of the corrosion-mechanical test results obtained with the results of acceptance tests are presented. A study of the fracture surfaces and the specimen material with the use of fractographic, macroscopic, and microscopic analyses is given. The systematization of the corrosion-mechanical test results with the use of methods of mathematical statistics are presented.

  13. Comparative Evaluation of Marginal Discrepancy in Tooth Colored Self Cure Acrylic Provisional Restorations With and Without Reinforcement of Glass Beads: An In-Vitro Study

    PubMed Central

    Yasangi, Manoj Kumar; Mannem, Dhanalakshmi; Neturi, Sirisha; Ravoori, Srinivas; Jyothi

    2015-01-01

    Context This invitro study was conducted to compare and evaluate marginal discrepancy in two types of tooth colored self cure provisional restorative materials {DPI&UNIFAST TRAD} before and after reinforcement of glass beads. Aim The aim of the present study was to evaluate and compare marginal discrepancy in two types of provisional restorative materials (DPI and UNI FAST TRAD) before and after reinforcement with Glass beads. Materials and Methods Tooth shaped resin copings were fabricated on custom made brass metal die. A total of 60 resin copings were fabricated in which 30 samples were prepared with DPI and 30 samples with UNIFAST material. Each group of 30 samples were divided in to two sub groups in which 15 samples were prepared with glass bead reinforcement and 15 samples without reinforcement. The marginal discrepancy was evaluated with photomicroscope {Reichet Polyvar 2 met} by placing the resin copings on custom made brass resin coping holder. Results Measurements obtained were statistically analysed by unpaired t-test to know any significance between two variables. Unreinforced DPI specimens had shown lower marginal discrepancy (442.82) than reinforced specimens (585.77). Unreinforced UNIFAST specimens have shown high values of marginal discrepancy (592.83) than reinforced specimens (436.35). p-value between reinforced and unreinforced specimens of DPI (p=0.0013) and UNIFAST (p= 0.0038) has shown statistical significance. Conclusion This in-vitro study revealed that unreinforced DPI specimens have shown lower marginal discrepancy than reinforced specimens and unreinforced UNIFAST specimens have shown higher values of marginal discrepancy than reinforced specimens. PMID:26155574

  14. Extraction of information from major element chemical analyses of lunar basalts

    NASA Technical Reports Server (NTRS)

    Butler, J. C.

    1985-01-01

    Major element chemical analyses often form the framework within which similarities and differences of analyzed specimens are noted and used to propose or devise models. When percentages are formed the ratios of pairs of components are preserved whereas many familiar statistical and geometrical descriptors are likely to exhibit major changes. This ratio preserving aspect forms the basis for a proposed framework. An analysis of compositional variability within the data set of 42 major element analyses of lunar reference samples was selected to investigate this proposal.

  15. Multivariate statistical analysis of low-voltage EDS spectrum images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, I.M.

    1998-03-01

    Whereas energy-dispersive X-ray spectrometry (EDS) has been used for compositional analysis in the scanning electron microscope for 30 years, the benefits of using low operating voltages for such analyses have been explored only during the last few years. This paper couples low-voltage EDS with two other emerging areas of characterization: spectrum imaging and multivariate statistical analysis. The specimen analyzed for this study was a finished Intel Pentium processor, with the polyimide protective coating stripped off to expose the final active layers.

  16. The effect of condensation pressure on selected physical properties of mineral trioxide aggregate.

    PubMed

    Nekoofar, M H; Adusei, G; Sheykhrezae, M S; Hayes, S J; Bryant, S T; Dummer, P M H

    2007-06-01

    To examine the effect of condensation pressure on surface hardness, microstructure and compressive strength of mineral trioxide aggregate (MTA). White ProRoot MTA (Dentsply Tulsa Dental, Johnson City, TN, USA) was mixed and packed into cylindrical polycarbonate tubes. Six groups each of 10 specimens were subjected to pressures of 0.06, 0.44, 1.68, 3.22, 4.46 and 8.88 MPa respectively. The surface hardness of each specimen was measured using Vickers microhardness. Cylindrical specimens of 4 mm in diameter and 6 mm in height were prepared in polycarbonate cylindrical moulds for testing the compressive strength. Five groups of 10 specimens were prepared using pressures of 0.06, 0.44, 1.68, 3.22 or 4.46 MPa. Data were subjected to one-way anova. The microstructure was analysed using a scanning electron microscope (SEM) after sectioning specimens with a scalpel. A trend was observed for higher condensation pressures to produce lower surface hardness values. A condensation pressure of 8.88 MPa produced specimens with significantly lower values in terms of surface hardness than other groups (P<0.001). A condensation pressure of 1.68 MPa conferred the maximum compressive strength; however, it was not statistically different. Higher condensation pressures resulted in fewer voids and microchannels when analysed with SEM. In specimens prepared with lower condensation pressures distinctive crystalline structures were observed. They tended to appear around microchannels. Condensation pressure may affect the strength and hardness of MTA. Use of controlled condensation pressure in sample preparation for future studies is suggested.

  17. Effect of bending on the room-temperature tensile strengths of structural ceramics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jenkins, M.G.

    1992-01-01

    Results for nearly fifty, room-temperature tensile tests conducted on two advanced, monolithic silicon nitride ceramics are evaluated for the effects of bending and application of various Weibull statistical analyses. Two specimen gripping systems (straight collet and tapered collet) were evaluated for both success in producing gage section failures and tendency to minimize bending at failure. Specimen fabrication and grinding technique consderations are briefly reviewed and related to their effects on successful tensile tests. Ultimate tensile strengths are related to the bending measured at specimen failure and the effects of the gripping system on bending are discussed. Finally, comparisons are mademore » between the use of censored and uncensored data sample sets for determining the maximum likelihood estimates of the Weibull parameters from the tensile strength distributions.« less

  18. Effect of bending on the room-temperature tensile strengths of structural ceramics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jenkins, M.G.

    1992-07-01

    Results for nearly fifty, room-temperature tensile tests conducted on two advanced, monolithic silicon nitride ceramics are evaluated for the effects of bending and application of various Weibull statistical analyses. Two specimen gripping systems (straight collet and tapered collet) were evaluated for both success in producing gage section failures and tendency to minimize bending at failure. Specimen fabrication and grinding technique consderations are briefly reviewed and related to their effects on successful tensile tests. Ultimate tensile strengths are related to the bending measured at specimen failure and the effects of the gripping system on bending are discussed. Finally, comparisons are mademore » between the use of censored and uncensored data sample sets for determining the maximum likelihood estimates of the Weibull parameters from the tensile strength distributions.« less

  19. Micromechanical investigation of sand migration in gas hydrate-bearing sediments

    NASA Astrophysics Data System (ADS)

    Uchida, S.; Klar, A.; Cohen, E.

    2017-12-01

    Past field gas production tests from hydrate bearing sediments have indicated that sand migration is an important phenomenon that needs to be considered for successful long-term gas production. The authors previously developed the continuum based analytical thermo-hydro-mechanical sand migration model that can be applied to predict wellbore responses during gas production. However, the model parameters involved in the model still needs to be calibrated and studied thoroughly and it still remains a challenge to conduct well-defined laboratory experiments of sand migration, especially in hydrate-bearing sediments. Taking the advantage of capability of micromechanical modelling approach through discrete element method (DEM), this work presents a first step towards quantifying one of the model parameters that governs stresses reduction due to grain detachment. Grains represented by DEM particles are randomly removed from an isotropically loaded DEM specimen and statistical analyses reveal that linear proportionality exists between the normalized volume of detached solids and normalized reduced stresses. The DEM specimen with different porosities (different packing densities) are also considered and statistical analyses show that there is a clear transition between loose sand behavior and dense sand behavior, characterized by the relative density.

  20. Certification of NIST Room Temperature Low-Energy and High-Energy Charpy Verification Specimens

    PubMed Central

    Lucon, Enrico; McCowan, Chris N.; Santoyo, Ray L.

    2015-01-01

    The possibility for NIST to certify Charpy reference specimens for testing at room temperature (21 °C ± 1 °C) instead of −40 °C was investigated by performing 130 room-temperature tests from five low-energy and four high-energy lots of steel on the three master Charpy machines located in Boulder, CO. The statistical analyses performed show that in most cases the variability of results (i.e., the experimental scatter) is reduced when testing at room temperature. For eight out of the nine lots considered, the observed variability was lower at 21 °C than at −40 °C. The results of this study will allow NIST to satisfy requests for room-temperature Charpy verification specimens that have been received from customers for several years: testing at 21 °C removes from the verification process the operator’s skill in transferring the specimen in a timely fashion from the cooling bath to the impact position, and puts the focus back on the machine performance. For NIST, it also reduces the time and cost for certifying new verification lots. For one of the low-energy lots tested with a C-shaped hammer, we experienced two specimens jamming, which yielded unusually high values of absorbed energy. For both specimens, the signs of jamming were clearly visible. For all the low-energy lots investigated, jamming is slightly more likely to occur at 21 °C than at −40 °C, since at room temperature low-energy samples tend to remain in the test area after impact rather than exiting in the opposite direction of the pendulum swing. In the evaluation of a verification set, any jammed specimen should be removed from the analyses. PMID:26958453

  1. Certification of NIST Room Temperature Low-Energy and High-Energy Charpy Verification Specimens.

    PubMed

    Lucon, Enrico; McCowan, Chris N; Santoyo, Ray L

    2015-01-01

    The possibility for NIST to certify Charpy reference specimens for testing at room temperature (21 °C ± 1 °C) instead of -40 °C was investigated by performing 130 room-temperature tests from five low-energy and four high-energy lots of steel on the three master Charpy machines located in Boulder, CO. The statistical analyses performed show that in most cases the variability of results (i.e., the experimental scatter) is reduced when testing at room temperature. For eight out of the nine lots considered, the observed variability was lower at 21 °C than at -40 °C. The results of this study will allow NIST to satisfy requests for room-temperature Charpy verification specimens that have been received from customers for several years: testing at 21 °C removes from the verification process the operator's skill in transferring the specimen in a timely fashion from the cooling bath to the impact position, and puts the focus back on the machine performance. For NIST, it also reduces the time and cost for certifying new verification lots. For one of the low-energy lots tested with a C-shaped hammer, we experienced two specimens jamming, which yielded unusually high values of absorbed energy. For both specimens, the signs of jamming were clearly visible. For all the low-energy lots investigated, jamming is slightly more likely to occur at 21 °C than at -40 °C, since at room temperature low-energy samples tend to remain in the test area after impact rather than exiting in the opposite direction of the pendulum swing. In the evaluation of a verification set, any jammed specimen should be removed from the analyses.

  2. Early hominid dental remains from Members 4 and 5 of the Sterkfontein Formation (1966-1996 excavations): catalogue, individual associations, morphological descriptions and initial metrical analysis.

    PubMed

    Moggi-Cecchi, Jacopo; Grine, Frederick E; Tobias, Phillip V

    2006-03-01

    The fossils recovered from the Sterkfontein Formation represent, without doubt, the largest collection of early hominid specimens from a single locality. Among the over 600 entries in the catalogue of fossil hominid specimens recovered since 1966, there are 242 dental remains (isolated teeth, jaws with two or more teeth, isolated teeth in association) for a total number of 495 teeth. The aim of this paper is to provide morphological descriptions of all hominid dental specimens recovered between 1968 and 1996 from areas presently known as Members 4 and 5 of the Sterkfontein site. Together with the descriptions, explanatory catalogue information is provided, along with basic measurements and summary statistics. This paper consists of six sections, with descriptive tables: (1) Catalogue of dental remains, arranged numerically. This includes isolated teeth, specimens with teeth still in position within their jaws, and specimens comprised of isolated teeth in association. (2) List of specimens with more complete dentition and the numbers of available teeth per tooth class. (3) List of specimens subdivided in tooth class, with an indication of their preservation, of the wear, if any, and with measurements (mesiodistal and buccolingual diameters) of the individual teeth. (4) List of associations of isolated teeth as individuals i.e. dental remains that can be associated with one another. Some remarks on the relative abundance of maxillary versus mandibular teeth, and on the numbers of available teeth are presented. (5) Morphological descriptions. (6) Summary statistics for the entire Sterkfontein sample (thus including specimens recovered both before and after 1966) and updated descriptive statistics for South African early hominids (A. africanus, A. robustus, South African early Homo). We have compared the coefficients of variation for the MD and BL diameters of the permanent teeth of the Sterkfontein Member 4 hypodigm of A. africanus with the hypodigms of the early hominid taxa. The results show that the Sterkfontein Member 4 sample is not consistently more variable than the other fossil hominid samples analysed; it turned out to be generally less variable than H. habilis sensu lato and A. boisei; it shows overall similar levels of variability to A. afarensis and higher levels than A. robustus. These results, per se, do not provide evidence of the existence of multiple species in the Sterkfontein Member 4 sample.

  3. Time trends of persistent organic pollutants in Sweden during 1993-2007 and relation to age, gender, body mass index, breast-feeding and parity.

    PubMed

    Hardell, Elin; Carlberg, Michael; Nordström, Marie; van Bavel, Bert

    2010-09-15

    Persistent organic pollutants (POPs) are lipophilic chemicals that bioaccumulate. Most of them were resticted or banned in the 1970s and 1980s to protect human health and the environment. The main source for humans is dietary intake of dairy products, meat and fish. Little data exist on changes of the concentration of POPs in the Swedish population over time. To study if the concentrations of polychlorinated biphenyls (PCBs), DDE, hexachlorobenzene (HCB) and chlordanes have changed in the Swedish population during 1993-2007, and certain factors that may influence the concentrations. During 1993-2007 samples from 537 controls in different human cancer studies were collected and analysed. Background information such as body mass index, breast-feeding and parity was assessed by questionaires. Wilcoxon rank-sum test was used to analyse the explanatory factors specimen (blood or adipose tissue), gender, BMI, total breast-feeding and parity in relation to POPs. Time trends for POPs were analysed using linear regression analysis, adjusted for specimen, gender, BMI and age. The concentration decreased for all POPs during 1993-2007. The annual change was statistically significant for the sum of PCBs -7.2%, HCB -8.8%, DDE -13.5% and the sum of chlordanes -10.3%. BMI and age were determinants of the concentrations. Cumulative breast-feeding >8 months gave statistically significantly lower concentrations for the sum of PCBs, DDE and the sum of chlordanes. Parity with >2 children yielded statistically significantly lower sum of PCBs. All the studied POPs decreased during the time period, probably due to restrictions of their use. Copyright 2010 Elsevier B.V. All rights reserved.

  4. Evaluation of bleaching efficacy of 37.5% hydrogen peroxide on human teeth using different modes of activations: An in vitro study

    PubMed Central

    Bhutani, Neha; Venigalla, Bhuvan Shome; Patil, Jaya Prakash; Singh, Thakur Veerandar; Jyotsna, Sistla Venkata; Jain, Abhilasha

    2016-01-01

    Introduction: The aim of this in vitro study is to evaluate the role of light and laser sources in the bleaching ability of 37.5% H2 O2 on extracted human teeth. Materials and Methods: About 30 caries-free single-rooted maxillary central incisors were used for the study. Specimens were prepared by sectioning the crown portion of teeth mesiodistally, and labial surface was used for the study. Specimens were then immersed in coffee solution for staining. Color of each tooth was analyzed using Shadestar, a digital shademeter. Specimens were then divided into three groups of 10 each and were subjected to bleaching with 37.5% H2 O2, 37.5% H2 O2 + light activation, and 37.5% H2 O2 + laser activation, respectively. Postbleaching, the color was analyzed for all the specimens immediately and then after 1, 2, and 3 weeks intervals, respectively. Results: All the statistical analyses were done using SPSS version 17. Intra- and inter-group comparisons were done with Friedman test and Kruskal–Wallis ANOVA, respectively. Statistical analysis concluded with a significant improvement in their shade values from baseline in all the three groups. Halogen light activation and laser-activated groups showed comparatively enhanced bleaching results over no-activation group, though the difference was not statistically significant. Conclusion: The results of the present study show that bleaching assisted with halogen light and laser showed increased lightness than nonlight activated group. Durability of bleaching results obtained postbleaching was maintained throughout the experimental trail period of 3 weeks for both halogen light and laser activation group, whereas no-light activation group presented with shade rebound after 2 weeks postbleaching. PMID:27217641

  5. Analysis of STAT laboratory turnaround times before and after conversion of the hospital information system.

    PubMed

    Lowe, Gary R; Griffin, Yolanda; Hart, Michael D

    2014-08-01

    Modern electronic health record systems (EHRS) reportedly offer advantages including improved quality, error prevention, cost reduction, and increased efficiency. This project reviewed the impact on specimen turnaround times (TAT) and percent compliance for specimens processed in a STAT laboratory after implementation of an upgraded EHRS. Before EHRS implementation, laboratory personnel received instruction and training for specimen processing. One laboratory member per shift received additional training. TAT and percent compliance data sampling occurred 4 times monthly for 13 months post-conversion and were compared with the mean of data collected for 3 months pre-conversion. Percent compliance was gauged using a benchmark of reporting 95% of all specimens within 7 min from receipt. Control charts were constructed for TAT and percent compliance with control limits set at 2 SD and applied continuously through the data collection period. TAT recovered to pre-conversion levels by the 6th month post-conversion. Percent compliance consistently returned to pre-conversion levels by the 10th month post-conversion. Statistical analyses revealed the TAT were significantly longer for 3 months post-conversion (P < .001) compared with pre-conversion levels. Statistical significance was not observed for subsequent groups. Percent compliance results were significantly lower for 6 months post-conversion (P < .001). Statistical significance was not observed for subsequent groups. Extensive efforts were made to train and prepare personnel for challenges expected after the EHRS upgrade. Specific causes identified with the upgraded EHRS included multiple issues involving personnel and the EHRS. These data suggest that system and user issues contributed to delays in returning to pre-conversion TAT and percent compliance levels following the upgrade in the EHRS.

  6. The Infectious Pathogenesis of Prostate Cancer

    DTIC Science & Technology

    2009-03-01

    prostate cancer. A manuscript of these data is currently under peer-review. Propionibacterium acnes is a bacterium which has previously been...completed an evaluation of the tissue specimens for evidence of P acnes with collaborators at the University of Orebro, Sweden using a FISH assay...Almost 20 percent of men had evidence of P acnes infection in the tissue. We are now undertaking statistical analyses to evaluate the association of P

  7. Creep-rupture behavior of 6 candidate stirling engine iron-base superalloys in high pressure hydrogen. Volume 1: Air creep-rupture behavior

    NASA Technical Reports Server (NTRS)

    Bhattacharyya, S.

    1982-01-01

    Four wrought alloys (A-286, IN 800H, N-155, and 19-9DL) and two cast alloys (CRM-6D and XF-818) were tested to determine their creep-rupture behavior. The wrought alloys were used in the form of sheets of 0.89 mm (0.035 in.) average thickness. The cast alloy specimens were investment cast and machined to 6.35 mm (0.250 in.) gage diameter. All specimens were tested to rupture in air at different times up to 3000 h over the temperature range of 650 C to 925 C (1200 F to 1700 F). Rupture life, minimum creep rate, and time to 1% creep strain were statistically analyzed as a function of stress at different temperatures. Temperature-compensated analysis was also performed to obtain the activation energies for rupture life, time to 1% creep strain, and the minimum creep rate. Microstructural and fracture analyses were also performed. Based on statistical analyses, estimates were made for stress levels at different temperatures to obtain 3500 h rupture life and time to 1% creep strain. Test results are to be compared with similar data being obtained for these alloys under 15 MPa (2175 psi) hydrogen.

  8. Evaluation of Solid Rocket Motor Component Data Using a Commercially Available Statistical Software Package

    NASA Technical Reports Server (NTRS)

    Stefanski, Philip L.

    2015-01-01

    Commercially available software packages today allow users to quickly perform the routine evaluations of (1) descriptive statistics to numerically and graphically summarize both sample and population data, (2) inferential statistics that draws conclusions about a given population from samples taken of it, (3) probability determinations that can be used to generate estimates of reliability allowables, and finally (4) the setup of designed experiments and analysis of their data to identify significant material and process characteristics for application in both product manufacturing and performance enhancement. This paper presents examples of analysis and experimental design work that has been conducted using Statgraphics®(Registered Trademark) statistical software to obtain useful information with regard to solid rocket motor propellants and internal insulation material. Data were obtained from a number of programs (Shuttle, Constellation, and Space Launch System) and sources that include solid propellant burn rate strands, tensile specimens, sub-scale test motors, full-scale operational motors, rubber insulation specimens, and sub-scale rubber insulation analog samples. Besides facilitating the experimental design process to yield meaningful results, statistical software has demonstrated its ability to quickly perform complex data analyses and yield significant findings that might otherwise have gone unnoticed. One caveat to these successes is that useful results not only derive from the inherent power of the software package, but also from the skill and understanding of the data analyst.

  9. Effects of heat-treatment and explosive brisance on fragmentation of high strength steel

    NASA Astrophysics Data System (ADS)

    Stolken, James; Kumar, Mukul; Gold, Vladimir; Baker, Ernest; Lawrence Livermore Nationa Laboratory Collaboration; Armament Research Development; Eng Collaboration

    2011-06-01

    Tubes of AISI-4340 steel were heat-treated to three distinct microstructures resulting in nominal hardness values of 25 Rc, 38 Rc and 48 Rc. The specimens were then explosively fragmented using TNT and PETN. The experiments were conducted in a contained firing facility with high fragment collection efficiency. Statistical analyses of recovered fragments were performed. Fragment rank-order statistics and generalized goodness-of-fit tests were used to characterize the fragment mass distributions. These analyses indicated significant interaction effects between the heat-treatment (and the resulting microstructure) and the explosive brisance. The role of the microstructure in relation to the yield-strength and toughness will also be discussed. This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  10. The fossil record and taphonomy of butterflies and moths (Insecta, Lepidoptera): implications for evolutionary diversity and divergence-time estimates.

    PubMed

    Sohn, Jae-Cheon; Labandeira, Conrad C; Davis, Donald R

    2015-02-04

    It is conventionally accepted that the lepidopteran fossil record is significantly incomplete when compared to the fossil records of other, very diverse, extant insect orders. Such an assumption, however, has been based on cumulative diversity data rather than using alternative statistical approaches from actual specimen counts. We reviewed documented specimens of the lepidopteran fossil record, currently consisting of 4,593 known specimens that are comprised of 4,262 body fossils and 331 trace fossils. The temporal distribution of the lepidopteran fossil record shows significant bias towards the late Paleocene to middle Eocene time interval. Lepidopteran fossils also record major shifts in preservational style and number of represented localities at the Mesozoic stage and Cenozoic epoch level of temporal resolution. Only 985 of the total known fossil specimens (21.4%) were assigned to 23 of the 40 extant lepidopteran superfamilies. Absolute numbers and proportions of preservation types for identified fossils varied significantly across superfamilies. The secular increase of lepidopteran family-level diversity through geologic time significantly deviates from the general pattern of other hyperdiverse, ordinal-level lineages. Our statistical analyses of the lepidopteran fossil record show extreme biases in preservation type, age, and taxonomic composition. We highlight the scarcity of identified lepidopteran fossils and provide a correspondence between the latest lepidopteran divergence-time estimates and relevant fossil occurrences at the superfamily level. These findings provide caution in interpreting the lepidopteran fossil record through the modeling of evolutionary diversification and in determination of divergence time estimates.

  11. Drop-Weight Impact Test on U-Shape Concrete Specimens with Statistical and Regression Analyses

    PubMed Central

    Zhu, Xue-Chao; Zhu, Han; Li, Hao-Ran

    2015-01-01

    According to the principle and method of drop-weight impact test, the impact resistance of concrete was measured using self-designed U-shape specimens and a newly designed drop-weight impact test apparatus. A series of drop-weight impact tests were carried out with four different masses of drop hammers (0.875, 0.8, 0.675 and 0.5 kg). The test results show that the impact resistance results fail to follow a normal distribution. As expected, U-shaped specimens can predetermine the location of the cracks very well. It is also easy to record the cracks propagation during the test. The maximum of coefficient of variation in this study is 31.2%; it is lower than the values obtained from the American Concrete Institute (ACI) impact tests in the literature. By regression analysis, the linear relationship between the first-crack and ultimate failure impact resistance is good. It can suggested that a minimum number of specimens is required to reliably measure the properties of the material based on the observed levels of variation. PMID:28793540

  12. Effects of silicon coating on bond strength of two different titanium ceramic to titanium.

    PubMed

    Ozcan, Isil; Uysal, Hakan

    2005-08-01

    This study investigated the effect of silicon coating (SiO2) by magnetron sputtering on bond strength of two different titanium ceramics to titanium. Sixty cast titanium specimens were prepared following the protocol ISO 9693. Titanium specimens were divided into two test and control groups with 15 specimens in each. Test groups were silicon coated by the magnetron sputtering technique. Two titanium ceramics (Triceram and Duceratin) were applied on both test (coated) and control (uncoated) metal specimens. The titanium-ceramic specimens were subjected to a three point flexural test. The groups were compared for their bond strength. SEM and SEM/EDS analyses were performed on the delaminated titanium surfaces to ascertain bond failure. The mean bond strength of Ti-Duceratin, Ti-Triceram, Si-coated Ti-Duceratin and Si-coated Ti-Triceram were 17.22+/-2.43, 23.31+/-3.18, 23.21+/-3.81 and 24.91+/-3.70 MPa, respectively. While the improvement in bond strength was 30% for Duceratin, it was statistically insignificant for Triceram. An adhesive mode of failure was observed in the Duceratin control group. In the silicoated Duceratin specimen, the bonded ceramic boundaries were wider but less than in the silicoated Triceram specimen. In the coated Triceram specimen, the ceramic retained areas were frequent and the failure mode was generally cohesive. Silicon coating was significantly effective in both preventing titanium oxide layer formation and in improving bond strength for Duceratin. However, it was of less value for Triceram.

  13. The interactive effect of the degradation of cotton clothing and decomposition fluid production associated with decaying remains.

    PubMed

    Ueland, Maiken; Nizio, Katie D; Forbes, Shari L; Stuart, Barbara H

    2015-10-01

    Textiles are a commonly encountered source of evidence in forensic cases. In the past, most research has been focused on how textiles affect the decomposition process while little attention has been paid to how the decomposition products interact with the textiles. While some studies have shown that the presence of remains will have an effect on the degradation of clothing associated with a decaying body, very little work has been carried out on the specific mechanisms that prevent or delay textile degradation when in contact with decomposing remains. In order to investigate the effect of decomposition fluid on textile degradation, three clothed domestic pig (Sus scrofa domesticus) carcasses were placed on a soil surface, textile specimens were collected over a period of a year and were then analysed using ATR-FTIR spectroscopy and GC-MS. Multivariate statistical analysis was used to analyse the data. Cotton specimens not associated with remains degraded markedly, whereas the samples exposed to decomposition fluids remained relatively intact over the same time frame. An investigation of the decomposition by-products found that the protein-related bands remained stable and unchanged throughout the experiment. Lipid components, on the other hand, demonstrated a significant change; this was confirmed with the use of both ATR-FTIR spectroscopy and GC-MS. Through an advanced statistical approach, information about the decomposition by-products and their characteristics was obtained. There is potential that the lipid profile in a textile specimen could be a valuable tool used in the examination of clothing located at a crime scene. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  14. In Vitro Evaluation of Shear Bond Strength of Nanocomposites to Dentin

    PubMed Central

    Vellanki, Vinay Kumar; Shetty, Vikram K; Kushwah, Sudhanshu; Goyal, Geeta; Chandra, S.M. Sharath

    2015-01-01

    Aims: To compare the shear bond strength of nanocomposites to dentin using three different types of adhesive systems; and to test few specimens under Scanning Electron Microscope (SEM) for analysing whether the bond failure is adhesive or cohesive. Materials and Methods: Sixty human premolar teeth were selected and were randomly grouped, with 20 specimens in each group: group 1 - fluoride releasing dentin bonding agent; group 2 - antibacterial containing dentin bonding agent; and group 3 - one step conventional self etch adhesive. Each group was treated with its respective bonding agents, composite resin build up was done, and shear bond strengths were tested using Instron Universal testing machine. Few of the specimens were tested under SEM. Results: The results were statistically analysed using One-way ANOVA and paired t-test. It was observed that group 3 has the highest shear bond strength followed by group 2, and then group 1. Adhesive failures and mixed failures were most frequent types of failures as seen under SEM. Conclusion: Addition of antimicrobial agent decreases the bond strength of dentin bonding agent and addition of fluoride further decreases the bond strength. From SEM results it can be concluded that the zone of failure could not be defined and also that the failure mode was independent of the dentin bonding agent used. PMID:25738077

  15. The Effect of Scale Dependent Discretization on the Progressive Failure of Composite Materials Using Multiscale Analyses

    NASA Technical Reports Server (NTRS)

    Ricks, Trenton M.; Lacy, Thomas E., Jr.; Pineda, Evan J.; Bednarcyk, Brett A.; Arnold, Steven M.

    2013-01-01

    A multiscale modeling methodology, which incorporates a statistical distribution of fiber strengths into coupled micromechanics/ finite element analyses, is applied to unidirectional polymer matrix composites (PMCs) to analyze the effect of mesh discretization both at the micro- and macroscales on the predicted ultimate tensile (UTS) strength and failure behavior. The NASA code FEAMAC and the ABAQUS finite element solver were used to analyze the progressive failure of a PMC tensile specimen that initiates at the repeating unit cell (RUC) level. Three different finite element mesh densities were employed and each coupled with an appropriate RUC. Multiple simulations were performed in order to assess the effect of a statistical distribution of fiber strengths on the bulk composite failure and predicted strength. The coupled effects of both the micro- and macroscale discretizations were found to have a noticeable effect on the predicted UTS and computational efficiency of the simulations.

  16. Iba Techniques to Study Renaissance Pottery Techniques

    NASA Astrophysics Data System (ADS)

    Bouquillon, A.; Castaing, J.; Salomon, J.; Zucchiatti, A.; Lucarelli, F.; Mando, P. A.; Prati, P.; Lanterna, G.; Vaccari, M. G.

    2001-09-01

    The application of Ion Beam Analysis, associated to Scanning Electron Microscopy is examined in connection with an extensive program on structural and chemical analyses of glazed terracotta's from the Italian Renaissance, launched by a French-Italian collaboration in the framework of the European COST-G1 scientific action. The objectives of the collaboration are reviewed. The compatibility of data from different specimen and various laboratories are discussed. Examples of the PIXE and statistical analyses on some artefacts of the "Robbiesche" type, supplied by the Louvre Museum of Paris and the Opificio delle Pietre Dure of Florence, are given to illustrate the performances of IBA in this particular field.

  17. Antibiotic Screening of Urine Culture for Internal Quality Audit at Amrita Hospital, Kochi.

    PubMed

    Suresh, Aswathy; Gopinathan, Anusha; Dinesh, Kavitha R; Kumar, Anil

    2017-07-01

    Urine antimicrobial activity is a seldom analysed laboratory test which greatly impacts the quantification of urine specimens. Presence of antimicrobial activity in the urine reduces the bacterial load in these specimens. Hence, the chances of erroneously reporting insignificant bacteriuria can be reduced on analysis of the antimicrobial activity in urine. The aim of the study was to measure the antimicrobial activity of urine samples obtained from patients in a tertiary care hospital. A total of 100 urine specimens were collected from the study group. Tests like wet mount, Gram staining and culture were performed. Antimicrobial susceptibility testing was done on the bacteria isolated from each specimen. The urine specimens were reported as significant bacteriuria (>105 Colony Forming Unit (CFU)/ml) and insignificant bacteriuria (<105 CFU/ml - clean catch midstream urine; <102 CFU/ml - catheterized urine sample) according to the CFU/ml. Staphylococcus aureus ATCC ® 25923 ™ and Escherichia coli ATCC ® 25922 ™ were used to identify the presence of antimicrobial activity in the urine sample by Urine Anti-Bacterial substance Assay (UABA). McNemar test was used for statistical analysis using Statistical Package for the Social Sciences (SPSS) version 21.0. On analysis of the antimicrobial activity of urine sample with the prior antibiotic history of the patients, 17 were true positives and 43 were true negatives. Twenty six of samples with UABA positivity were culture negative and 28 samples with UABA positivity were culture positive. Sensitivity and specificity of the test was 85% and 53.8% respectively. Accuracy of the test was 60%. The p-value of UABA was <0.001. Enterobacteriaceae was the most common bacterial family isolated from the urine specimens. A total of 85% patients responded to treatment. Presence of antimicrobial activity in urine has a great impact on the interpretation of urine culture reports. Identification of urine antimicrobial activity helps in evaluating the quantification of bacterial growth reported in urine culture. It facilitates speedy recovery of patients by early administration of antibiotics.

  18. Probability of detection of internal voids in structural ceramics using microfocus radiography

    NASA Technical Reports Server (NTRS)

    Baaklini, G. Y.; Roth, D. J.

    1986-01-01

    The reliability of microfocous X-radiography for detecting subsurface voids in structural ceramic test specimens was statistically evaluated. The microfocus system was operated in the projection mode using low X-ray photon energies (20 keV) and a 10 micro m focal spot. The statistics were developed for implanted subsurface voids in green and sintered silicon carbide and silicon nitride test specimens. These statistics were compared with previously-obtained statistics for implanted surface voids in similar specimens. Problems associated with void implantation are discussed. Statistical results are given as probability-of-detection curves at a 95 precent confidence level for voids ranging in size from 20 to 528 micro m in diameter.

  19. Probability of detection of internal voids in structural ceramics using microfocus radiography

    NASA Technical Reports Server (NTRS)

    Baaklini, G. Y.; Roth, D. J.

    1985-01-01

    The reliability of microfocus x-radiography for detecting subsurface voids in structural ceramic test specimens was statistically evaluated. The microfocus system was operated in the projection mode using low X-ray photon energies (20 keV) and a 10 micro m focal spot. The statistics were developed for implanted subsurface voids in green and sintered silicon carbide and silicon nitride test specimens. These statistics were compared with previously-obtained statistics for implanted surface voids in similar specimens. Problems associated with void implantation are discussed. Statistical results are given as probability-of-detection curves at a 95 percent confidence level for voids ranging in size from 20 to 528 micro m in diameter.

  20. Evaluation of shear bond strength of porcelain bonded to laser welded titanium surface and determination of mode of bond failure.

    PubMed

    Patil, Narendra P; Dandekar, Minal; Nadiger, Ramesh K; Guttal, Satyabodh S

    2010-09-01

    The aim of this study was to evaluate the shear bond strength of porcelain to laser welded titanium surface and to determine the mode of bond failure through scanning electron microscopy (SEM) and energy dispersive spectrophotometry (EDS). Forty five cast rectangular titanium specimens with the dimension of 10 mm x 8 mm x 1 mm were tested. Thirty specimens had a perforation of 2 mm diameter in the centre. These were randomly divided into Group A and B. The perforations in the Group B specimens were repaired by laser welding using Cp Grade II titanium wire. The remaining 15 specimens were taken as control group. All the test specimens were layered with low fusing porcelain and tested for shear bond strength. The debonded specimens were subjected to SEM and EDS. Data were analysed with 1-way analysis of variance and Student's t-test for comparison among the different groups. One-way analysis of variance (ANOVA) showed no statistically significant difference in shear bond strength values at a 5% level of confidence. The mean shear bond strength values for control group, Group A and B was 8.4 +/- 0.5 Mpa, 8.1 +/- 0.4 Mpa and 8.3 +/- 0.3 Mpa respectively. SEM/EDS analysis of the specimens showed mixed and cohesive type of bond failure. Within the limitations of the study laser welding did not have any effect on the shear bond strength of porcelain bonded to titanium.

  1. Long-term effects of seven cleaning methods on light transmittance, surface roughness, and flexural modulus of polyurethane retainer material.

    PubMed

    Agarwal, Manika; Wible, Emily; Ramir, Tyler; Altun, Sibel; Viana, Grace; Evans, Carla; Lukic, Henry; Megremis, Spiro; Atsawasuwan, Phimon

    2018-05-01

    To evaluate the long-term effects of seven different cleaning methods on light transmittance, surface roughness, and flexural modulus of a polyurethane retainer material. Polyurethane retainer specimens (Vivera®, Align Technology Inc) (70 specimens, n = 10 per method, 50.8 mm × 12.7 mm × 1.0 mm) were exposed to seven cleaning methods twice a week for 6 months. Before treatment and after 6 months, light transmittance, surface roughness, and flexural modulus of the specimens were quantified. Qualitative assessment of randomly selected specimens from each solution was performed at baseline and after 6 months using a scanning electron microscope. Statistical analyses were performed at the .05 significance level. Of the three test variables, light transmittance through the specimens was the only one that changed significantly from baseline to 6 months for all cleaning solutions, with all of them causing a decrease. However, except for 0.6% sodium hypochlorite showing a change in surface roughness values and 2.5% vinegar and toothbrushing showing an increase in flexural modulus, none of the other four cleaning methods resulted in significant changes in surface roughness or flexural modulus values for the polyurethane specimens between baseline and after 6 months. Of the seven cleaning methods, Invisalign® cleaning crystals, Polident®, and Listerine® showed the least amount of change in light transmittance values for the polyurethane specimens over 6 months, and they had no effect on surface roughness and flexural modulus values.

  2. Proper assessment of the JFK assassination bullet lead evidence from metallurgical and statistical perspectives.

    PubMed

    Randich, Erik; Grant, Patrick M

    2006-07-01

    The bullet evidence in the JFK assassination investigation was reexamined from metallurgical and statistical standpoints. The questioned specimens are comprised of soft lead, possibly from full-metal-jacketed Mannlicher-Carcano (MC), 6.5-mm ammunition. During lead refining, contaminant elements are removed to specified levels for a desired alloy or composition. Microsegregation of trace and minor elements during lead casting and processing can account for the experimental variabilities measured in various evidentiary and comparison samples by laboratory analysts. Thus, elevated concentrations of antimony and copper at crystallographic grain boundaries, the widely varying sizes of grains in MC bullet lead, and the 5-60 mg bullet samples analyzed for assassination intelligence effectively resulted in operational sampling error for the analyses. This deficiency was not considered in the original data interpretation and resulted in an invalid conclusion in favor of the single-bullet theory of the assassination. Alternate statistical calculations, based on the historic analytical data, incorporating weighted averaging and propagation of experimental uncertainties also considerably weaken support for the single-bullet theory. In effect, this assessment of the material composition of the lead specimens from the assassination concludes that the extant evidence is consistent with any number between two and five rounds fired in Dealey Plaza during the shooting.

  3. Proper Assessment of the JFK Assassination Bullet Lead Evidence from Metallurgical and Statistical Perspectives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Randich, E; Grant, P M

    2006-08-29

    The bullet evidence in the JFK assassination investigation was reexamined from metallurgical and statistical standpoints. The questioned specimens are comprised of soft lead, possibly from full-metal-jacketed Mannlicher-Carcano, 6.5-mm ammunition. During lead refining, contaminant elements are removed to specified levels for a desired alloy or composition. Microsegregation of trace and minor elements during lead casting and processing can account for the experimental variabilities measured in various evidentiary and comparison samples by laboratory analysts. Thus, elevated concentrations of antimony and copper at crystallographic grain boundaries, the widely varying sizes of grains in Mannlicher-Carcano bullet lead, and the 5-60 mg bullet samples analyzedmore » for assassination intelligence effectively resulted in operational sampling error for the analyses. This deficiency was not considered in the original data interpretation and resulted in an invalid conclusion in favor of the single-bullet theory of the assassination. Alternate statistical calculations, based on the historic analytical data, incorporating weighted averaging and propagation of experimental uncertainties also considerably weaken support for the single-bullet theory. In effect, this assessment of the material composition of the lead specimens from the assassination concludes that the extant evidence is consistent with any number between two and five rounds fired in Dealey Plaza during the shooting.« less

  4. Comparative morphological studies on four populations of the shrimp Rimicaris exoculata from the Mid-Atlantic Ridge

    NASA Astrophysics Data System (ADS)

    Vereshchaka, A. L.

    1997-11-01

    Four populations (a total of 677 specimens) of the hydrothermal shrimp species Rimicaris exoculata from three Mid-Atlantic Ridge vent fields were studied: Broken Spur (29°N), TAG (26°N), and "14-45" (14°N). Five morphological characters were analysed: number of dorsolateral spines on telson, telative carapace width, relative abdominal length, presence of "abnormal telson", and fat content. Dependences of each character upon shrimp size were analysed. Division of the shrimp ontogenesis on the basis of general morphology is proposed. Phenotypic analysis based upon five selected characters revealed statistically significant divergence between two populations within the same vent field TAG. Probable causes of observed divergence are discussed.

  5. Effect of bleaching on color stability and roughness of composite resins aged in staining beverage.

    PubMed

    Rodrigues, Camila Silva; Mozzaquatro, Lisandra Rossato; Dala Nora, Bárbara; Jacques, Letícia Borges; Mallmann, André

    2017-01-01

    Composite resin properties can be affected by contact with gel during bleaching procedures; however, there is no consensus about the effect of this contact on resin susceptibility to color change. This study aimed to evaluate staining susceptibility and surface roughness changes in 2 composite resins (Filtek Z250 XT and Filtek Z350 XT) after application of bleaching peroxides and storage in different media. Forty-two disc-shaped specimens of each composite were made, polished, and divided into 3 groups according to treatment type (35% hydrogen peroxide, 16% carbamide peroxide, or deionized water as a control group). These groups were subdivided into 2 groups according to immersion media (n = 7): deionized water or red wine. Color and average roughness (Ra) measurements were taken 24 hours after specimen preparation (T0), immediately after bleaching procedures (T1), and immediately after aging (staining; T2). Statistical analyses were performed using 2-way analyses of variance for repeated measurements and the Tukey test (P < 0.05). Bleaching resulted in minimal color change (ΔE* < 1) in all groups. Filtek Z350 XT specimens presented greater mean values of color change. The Ra values did not increase significantly after bleaching procedures or aging (staining) in all groups. Thus, bleaching agents did not significantly change the color or roughness of the composite resins used in this study.

  6. Contamination with HIV antibody may be responsible for false positive results in specimens tested on automated platforms running HIV 4th generation assays in a region of high HIV prevalence.

    PubMed

    Hardie, Diana Ruth; Korsman, Stephen N; Hsiao, Nei-Yuan; Morobadi, Molefi Daniel; Vawda, Sabeehah; Goedhals, Dominique

    2017-01-01

    In South Africa where the prevalence of HIV infection is very high, 4th generation HIV antibody/p24 antigen combo immunoassays are the tests of choice for laboratory based screening. Testing is usually performed in clinical pathology laboratories on automated analysers. To investigate the cause of false positive results on 4th generation HIV testing platforms in public sector laboratories, the performance of two automated platforms was compared in a clinical pathology setting, firstly on routine diagnostic specimens and secondly on known sero-negative samples. Firstly, 1181 routine diagnostic specimens were sequentially tested on Siemens and Roche automated 4th generation platforms. HIV viral load, western blot and follow up testing were used to determine the true status of inconclusive specimens. Subsequently, known HIV seronegative samples from a single donor were repeatedly tested on both platforms and an analyser was tested for surface contamination with HIV positive serum to identify how suspected specimen contamination could be occurring. Serial testing of diagnostic specimens yielded 163 weakly positive or discordant results. Only 3 of 163 were conclusively shown to indicate true HIV infection. Specimen contamination with HIV antibody was suspected, based on the following evidence: the proportion of positive specimens increased on repeated passage through the analysers; viral loads were low or undetectable and western blots negative or indeterminate on problem specimens; screen negative, 2nd test positive specimens tested positive when reanalysed on the screening assay; follow up specimens (where available) were negative. Similarly, an increasing number of known negative specimens became (repeatedly) sero-positive on serial passage through one of the analysers. Internal and external analyser surfaces were contaminated with HIV serum, evidence that sample splashes occur during testing. Due to the extreme sensitivity of these assays, contamination with minute amounts of HIV antibody can cause a negative sample to test positive. Better contamination control measures are needed on analysers used in clinical pathology environments, especially in regions where HIV sero-prevalence is high.

  7. Glass fibre-reinforced composite laced with chlorhexidine digluconate and yeast adhesion.

    PubMed

    Waltimo, T; Luo, G; Samaranayake, L P; Vallittu, P K

    2004-02-01

    The aim of this study was to lace dental glass fibre reinforced composite (FRC) prepreg with chlorhexidine digluconate and to examine the adherence of common oral fungal pathogen Candida albicans to FRC made of the prepreg. Four different test and control material groups each comprising 16 test specimens ((5.0 x 5.0 x 0.8) mm3) each were used as substrates for C. albicans adherence. A porous polymer pre-impregnated woven glass fibre prepreg was laced with solution of chlorhexidine gluconate and it was used with autopolymerized denture base polymer to fabricate FRC test specimens. Control group (Group 1) consisted of FRC test specimens stored in water. In Group 2, the test specimens were stored in 10% chlorhexidine digluconate solution for 24 h. Group 3 consisted of specimens fabricated using such fibre reinforcements which were pre-soaked in 20% chlorhexidine digluconate and dried before preparation with denture base resin, and followed by storage of the specimens in water. Group 4 was similar to Group 3 but instead of water storage the specimens were immersed in 10% chlorhexidine digluconate for 24 h. For the candidal adhesion assay the test and control specimens were incubated in standardized suspensions of four different strains of C. albicans, rinsed and prepared for light-microscopy. The mean number of adherent cells in each group was counted microscopically and analysed statistically. There were significantly (P < 0.05) more adherent C. albicans cells found in Group 1 than in the other three groups which did not differ significantly from each other. The lowest numbers of adherent cells were found in Group 3. Pretreating the porous polymer pre-impregnated glass fibre reinforcement with chlorhexidine digluconate result in reduction in the number of adherent yeast cells on the surface FRC material.

  8. Evaluating the efficiency of humic acid to remove micro-organisms from denture base material.

    PubMed

    Meriç, Gökçe; Güvenir, Meryem; Süer, Kaya

    2016-09-01

    To evaluate the efficiency of humic acid substances on removing micro-organisms from denture base materials. Old denture wearer needs effective, easy-use and safe denture-cleaning material. Square-shaped, heat-polymerised acrylic resin specimens (n = 550) were prepared and divided into five groups (n = 110 for each) corresponding to the microbial contamination (Candida albicans, Staphylococcus aureus, Bacillus cereus, Enterococcus faecalis, Pseudomonas aeruginosa). Contaminated specimens were randomly assigned to the application of five different denture-cleaning agents as follows (n = 20 for each): Kloroben, Corsodyl, Steradent, Corega, experimental solution with humic acid. Ten specimens were assessed as an experimental control carried out simultaneously for the treatment groups for each micro-organism. It was divided into two groups: negative control and positive control (n = 5 for each). All acrylic specimens were incubated 37°C for 24 h (for bacterial strains) and 37°C for 48 h (for yeast strains). After incubation period, all brain-heart infusion broths (BHI) which contain disinfectant acrylic specimens were cultured on 5% sheep blood agar (for bacteria) and Sabouraud dextrose agar (SDA) for yeast using loop. The numbers of colony-forming units per millilitre (CFU/ml) were calculated. The results were analysed by Mann-Whitney U-test and Kruskal-Wallis tests (p = 0.05). Corsodyl and Kloroben completely eliminated the adherence of all investigated micro-organisms (100%) and showed the highest removal activity compared with other cleaning agents (p < 0.05). There was no statistically significant difference between Corsodyl and Kloroben (p ≥ 0.05), and there was no statistically significant difference between Corega, Steradent and experimental solution (p ≥ 0.05). Humic acid could be used as an alternative 'natural' solution for denture-cleaning agent. © 2014 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  9. DNA barcoding and regional diversity of understudied Micropeplinae (Coleoptera: Staphylinidae) in Southwest China: phylogenetic implications and a new Micropeplus from Mount Emei.

    PubMed

    Grebennikov, Vasily V; Smetana, Aleš

    2015-02-18

    Extensive litter sampling at eight forested localities in Yunnan and Sichuan detected 381 specimens of Micropeplinae rove beetles. DNA barcoding data from 85 representative specimens were analysed to delimit species and infer their relationships. Statistical methods were implemented to assess regional species diversity of understudied Micropeplinae. The total number of sampled Micropeplinae species varied between 14 and 17, depending on a splitting versus lumping approach for allopatric populations. A single Micropeplinae species was sampled in six of eight studied localities, three species were found on Mount Gongga, while ten species were discovered on hyperdiverse Mount Emei in Sichuan. All Micropeplinae specimens from our samples belong either to the genus Cerapeplus, or to three other inclusive groups temporarily retained inside Micropeplus sensu lato. Each of the three groups potentially represents a separate genus: tesserula group, sculptus group and Micropeplus sensu stricto. A new species Micropeplus jason sp. n. from Mount Emei in Sichuan is described. Numerous illustrations introduce regional fauna and clarify the discussed morphological characters.

  10. Coordinated Expression of Cyclin-dependent Kinase-4 and its Regulators in Human Oral Tumors

    PubMed Central

    POI, MING J.; KNOBLOCH, THOMAS J.; SEARS, MARTA T.; UHRIG, LANA K.; WARNER, BLAKE M.; WEGHORST, CHRISTOPHER M.; LI, JUNAN

    2014-01-01

    Background/Aim While aberrant expression of cyclin-dependent kinase-4 (CDK4) has been found in squamous cell carcinoma of the head and neck (SCCHN), the associations between CDK4 and its regulators, namely, cyclin D1, cyclin E, gankyrin, SEI1, and BMI1 in gene expression remain to be explored. Herein we investigated the mRNA profiles of these oncogenes and their interrelations in different oral lesion tissues. Materials and Methods Thirty SCCHN specimens and patient-matched high at-risk mucosa (HARM) and 16 healthy control specimens were subjected to quantitative reverse transcription-polymerase chain reaction (qRT-PCR) analyses. Results The mRNA levels of CDK4, cyclin D1, gankyrin, SEI1, BMI1 were significantly elevated in both HARM and SCCHN (in comparison with control specimens), and statistically significant correlations were found among these markers in gene expression. Conclusion Up-regulation of CDK4 and its regulators takes place in oral cancer progression in a coordinate manner, and HARM and SCCHN share a similar molecular signature within the CDK4-pRB pathway. PMID:24982332

  11. Heavy metals found in the breathing zone, toenails and lung function of welders working in an air-conditioned welding workplace.

    PubMed

    Hariri, Azian; Mohamad Noor, Noraishah; Paiman, Nuur Azreen; Ahmad Zaidi, Ahmad Mujahid; Zainal Bakri, Siti Farhana

    2017-09-22

    Welding operations are rarely conducted in an air-conditioned room. However, a company would set its welding operations in an air-conditioned room to maintain the humidity level needed to reduce hydrogen cracks in the specimen being welded. This study intended to assess the exposure to metal elements in the welders' breathing zone and toenail samples. Heavy metal concentration was analysed using inductively coupled plasma mass spectrometry. The lung function test was also conducted and analysed using statistical approaches. Chromium and manganese concentrations in the breathing zone exceeded the permissible exposure limit stipulated by Malaysian regulations. A similar trend was obtained in the concentration of heavy metals in the breathing zone air sampling and in the welders' toenails. Although there was no statistically significant decrease in the lung function of welders, it is suggested that exposure control through engineering and administrative approaches should be considered for workplace safety and health improvement.

  12. Banff study of pathologic changes in lung allograft biopsy specimens with donor-specific antibodies.

    PubMed

    Wallace, William Dean; Li, Ning; Andersen, Claus B; Arrossi, A Valeria; Askar, Medhat; Berry, Gerry J; DeNicola, Matthew M; Neil, Desley A; Pavlisko, Elizabeth N; Reed, Elaine F; Remmelink, Myriam; Weigt, S Sam; Weynand, Birgit; Zhang, Jennifer Q; Budev, Marie M; Farver, Carol F

    2016-01-01

    The diagnosis of antibody-mediated rejection (AMR) in the lung transplant is still an area under investigation. We performed a blinded multicenter study to determine if any statistically significant histologic findings in transbronchial biopsy specimens from lung transplant patients correlate with the presence of donor-specific antibodies (DSAs). We asked 9 pathologists with experience in lung transplantation to evaluate 161 lung transplant biopsy specimens for various histologic parameters. The findings were correlated with antibody status positive for DSAs, positive for non-DSAs, and no antibodies (NABs) present. The significance of each histologic variable was reviewed. We found no statistically significant association with acute cellular rejection, airway inflammation, or bronchiolitis obliterans and the presence or absence of antibodies. However, biopsy specimens with DSAs had a statistically significant difference vs NABs in the setting of acute lung injury, with or without diffuse alveolar damage (p = 0.0008), in the presence of capillary neutrophilic inflammation (p = 0.0014), and in samples with endotheliitis (p = 0.0155). In samples with complement 4d staining, there was a trend but no statistically significant difference between specimens associated with DSAs and specimens with NABs. Capillary inflammation, acute lung injury, and endotheliitis significantly correlated with DSAs. The infrequently observed diffuse staining for complement 4d limits the usefulness of this stain. Copyright © 2016 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  13. The study of the oipA and dupA genes in Helicobacter pylori strains and their relationship with different gastroduodenal diseases.

    PubMed

    Souod, Negar; Sarshar, Meysam; Dabiri, Hossein; Momtaz, Hassan; Kargar, Mohammad; Mohammadzadeh, Alireza; Abdi, Saeed

    2015-01-01

    The purpose of this investigation was to determine the oipA and dupA genes of Helicobacter pylori isolates from west of Iran; Chaharmahalo Bakhtiyari region and find their relationship with the severity of the gastroduodenal diseases. Helicobacter pylori is an organism responsible for many gastroduodenal diseases. Many studies suggest that genetic diversity in H . pylori virulence factors such as oipA and dupA genes is high among isolates of different geographic regions and may cause more severe diseases. In this cross-sectional study, gastric biopsy specimens were taken from 150 patients suffering from gastroduodenal diseases. The presence of ureC, dupA and oipA genes was tested by polymerase chain reaction (PCR). Overall, 123 (82%) H. pylori strains were isolated from 150 specimens. dupA gene was detected in 41 (33.33%) H.pylori-positive specimens. There was a reverse correlation between this gene and gastric cancer. The oipA gene was found in 88 (71.54%) samples and statistically there was no association between this gene and gastric disorders. As statistical analyses revealed, the presence of the dupA was more common in isolates with the oipA negative. Based on our findings, the presence of dupA gene can be considered as a marker for the onset of severe diseases. However, the oipA gene cannot be regarded for prediction of gastroenterology diseases. Meanwhile, extended molecular epidemiology researches in other populations are recommended.

  14. Light microscopic histology of supraspinatus tendon ruptures.

    PubMed

    Longo, Umile Giuseppe; Franceschi, Francesco; Ruzzini, Laura; Rabitti, Carla; Morini, Sergio; Maffulli, Nicola; Forriol, Francisco; Denaro, Vincenzo

    2007-11-01

    We analysed the morphological features of the human surgical specimens of supraspinatus tendon from patients with rotator cuff tears. Tendon samples were harvested from 31 subjects (21 men and 10 women; mean age 51 years, range 38-64) who underwent arthroscopic repair of a rotator cuff tear, and from five male patients who died of cardiovascular events (mean age, 69.6 years). Histological examination was performed using Haematoxylin and Eosin, Masson's Trichrome and Van Gieson's connective tissue stain. The specimens were examined twice by the same examiner under white light and polarized light microscopy. Particular effort was made to assess any evidence of the changes associated with tendinopathy. Within each specific category of tendon abnormalities, the chi-square test showed significant differences between the control and ruptured tendons (P < 0.05). Using the kappa statistics, the agreement between the two readings ranged from 0.57 to 0.84. We found thinning and disorientation of collagen fibres and chondroid metaplasia to be more pronounced on the articular side of the specimens from patients with rotator cuff tear (P < 0.05). The present study provides a description of the histological architecture of human surgical specimens of normal supraspinatus tendon from patients with rotator cuff tears and demonstrates more frequent tendon changes on the articular side of the rotator cuff.

  15. Role of human papilloma virus-16 in the pathogenesis of oral lichen planus--an immunohistochemical study.

    PubMed

    Pol, Chetan A; Ghige, Suvarna K; Gosavi, Suchitra R

    2015-02-01

    Oral lichen planus (OLP) is a common chronic inflammatory immune-mediated disease with an aetiopathogenesis associated with cell-mediated immunological dysfunction. It is possible that oral mucosal viral infections, including human papilloma virus-16 (HPV-16) infection, may have a causative role in OLP pathogenesis. To assess the prevalence of HPV-16 in histopathologically diagnosed specimens of OLP and to evaluate whether any clinical features (such as the localisation of specimens) or the age or gender of patients, are correlated with the presence of this virus. This study was conducted on 30 specimens with a histopathological diagnosis of OLP, using the immunohistochemical marker HPV-16. Thirty normal oral mucosa specimens were also included as controls. Brown nuclear staining was accepted as positive for the HPV-16 antibody. The results were analysed using Fisher's exact test. P values<0.05 were considered to be significant. Significant correlation (P=0.0001) was observed between HPV-16 infection and samples with OLP. No statistical conclusions could be drawn regarding age, gender, localisation and HPV-16 positivity. Our study showed that HPV-16 may play a role in the pathogenesis of OLP. Taking into account the oncogenic potential of HPV-16, patients with OLP should be screened for the presence of this virus. © 2014 FDI World Dental Federation.

  16. Prevention of dentine erosion by brushing with anti-erosive toothpastes.

    PubMed

    Aykut-Yetkiner, Arzu; Attin, Thomas; Wiegand, Annette

    2014-07-01

    This in vitro study aimed to investigate the preventive effect of brushing with anti-erosive toothpastes compared to a conventional fluoride toothpaste on dentine erosion. Bovine dentine specimens (n=12 per subgroup) were eroded in an artificial mouth (6 days, 6×30 s/day) using either citric acid (pH:2.5) or a hydrochloric acid/pepsin solution (pH:1.6), simulating extrinsic or intrinsic erosive conditions, respectively. In between, the specimens were rinsed with artificial saliva. Twice daily, the specimens were brushed for 15 s in an automatic brushing machine at 2.5 N with a conventional fluoride toothpaste slurry (elmex, AmF) or toothpaste slurries with anti-erosive formulations: Apacare (NaF/1% nHAP), Biorepair (ZnCO3-HAP), Chitodent (Chitosan), elmex Erosionsschutz (NaF/AmF/SnCl2/Chitosan), mirasensitive hap (NaF/30% HAP), Sensodyne Proschmelz (NaF/KNO3). Unbrushed specimens served as control. Dentine loss was measured profilometrically and statistically analysed using two-way and one-way ANOVA followed by Scheffe's post hoc tests. RDA-values of all toothpastes were determined, and linear mixed models were applied to analyse the influence of toothpaste abrasivity on dentine wear (p<0.05). Dentine erosion of unbrushed specimens amounted to 5.1±1.0 μm (extrinsic conditions) and 12.9±1.4 μm (intrinsic conditions). All toothpastes significantly reduced dentine erosion by 24-67% (extrinsic conditions) and 21-40% (intrinsic conditions). Biorepair was least effective, while all other toothpastes were not significantly different from each other. Linear mixed models did not show a significant effect of the RDA-value of the respective toothpaste on dentine loss. Toothpastes with anti-erosive formulations reduced dentine erosion, especially under simulated extrinsic erosive conditions, but were not superior to a conventional fluoride toothpaste. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Lost in translation or deliberate falsification? Genetic analyses reveal erroneous museum data for historic penguin specimens.

    PubMed

    Boessenkool, Sanne; Star, Bastiaan; Scofield, R Paul; Seddon, Philip J; Waters, Jonathan M

    2010-04-07

    Historic museum specimens are increasingly used to answer a wide variety of questions in scientific research. Nevertheless, the scientific value of these specimens depends on the authenticity of the data associated with them. Here we use individual-based genetic analyses to demonstrate erroneous locality information for archive specimens from the late nineteenth century. Specifically, using 10 microsatellite markers, we analysed 350 contemporary and 43 historic yellow-eyed penguin (Megadyptes antipodes) specimens from New Zealand's South Island and sub-Antarctic regions. Factorial correspondence analysis and an assignment test strongly suggest that eight of the historic specimens purportedly of sub-Antarctic origin were in fact collected from the South Island. Interestingly, all eight specimens were obtained by the same collector, and all are currently held in the same museum collection. Further inspection of the specimen labels and evaluation of sub-Antarctic voyages did not reveal whether the erroneous data are caused by incorrect labelling or whether deliberate falsification was at play. This study highlights a promising extension to the well-known applications of assignment tests in molecular ecology, which can complement methods that are currently being applied for error detection in specimen data. Our results also serve as a warning to all who use archive specimens to invest time in the verification of collection information.

  18. Discoloration of Provisional Restorations after Oral Rinses

    PubMed Central

    Turgut, Sedanur; Bagis, Bora; Ayaz, Elif Aydogan; Ulusoy, Kıvanç Utku; Altintas, Subutay Han; Korkmaz, Fatih Mehmet; Bagis, Nilsun

    2013-01-01

    Purpose: Oral rinses are widely used to promote periodontal health with provisional restorations during the interim period. The aim of this study was to compare the discoloration of provisional restoration materials with different oral rinses. Material and Methods: A total of 140 disc-shaped specimens (shade A2) (10 mm x 2 mm) were prepared from one PMMA-based (TemDent Classic®) and three different bis-acrylic-based (Protemp II®, Luxatemp® and Fill-In®) provisional restoration materials (n=7). The color values (L*, a*, and b*) of each specimen were measured before and after exposure with a colorimeter, and the color changes (∆E) were calculated according to the CIE L*a*b* system. The specimens were immersed in each of the 4 oral rinses (alcohol-containing mouthwash, chlorhexidine, benzydamine HCl, benzydamine HCl and chlorhexidine) twice a day for 2 minutes. After 2 minutes of immersion in the oral rinses, the specimens were immersed in artificial saliva. The specimens were exposed to the oral rinses and the artificial saliva for 3 weeks. Two-way ANOVA, the Bonferroni test and the paired sample t-test were used for statistical analyses (p<0.05). Results: Comparison of the discoloration from the oral rinses after immersion for three weeks revealed no significant differences (p>0.05). The lowest color change was observed in PMMA-based Temdent in all oral rinses (p<0.05). There were no significant differences between the bis-acryl composites after immersion in saliva or the mixture of benzydamine HCl and chlorhexidine and the alcohol-containing mouthwash for 3 weeks (p>0.05). After immersion in chlorhexidine, the color change values of Protemp II and Fill-in showed significant differences (p=0.018). Protemp II also showed less discoloration than the other bis-acryl composites, and this color change was statistically significant (p <0.05). For all oral rinses, the L* value decreased while b* values increased, and this color change was found to be statistically significant (p <0.05). A* values were found to be significantly higher with oral rinses (p<0.05), except Protemp II immersed in benzydamine HCl or alcohol-containing mouthwash. Conclusions: The type of the oral rinse did not affect the discoloration process. For long-term esthetic results, choosing MMA-based materials for provisional restorations appears to be more effective. PMID:24046524

  19. Effect of resin coating as a means of preventing marginal leakage beneath full cast crowns.

    PubMed

    Kosaka, Satomi; Kajihara, Hirotada; Kurashige, Hisanori; Tanaka, Takuo

    2005-03-01

    The purpose of this study was to evaluate the effectiveness of resin coating as a means of preventing marginal leakage beneath full cast crowns which were emplaced using different cements. Standard full cast crown preparation was made on 64 extracted premolars. These samples were then divided into four groups, with half of each group coated with dentin coating material after preparation. Crowns were cemented onto the teeth using zinc cement, Fuji I, Vitremer, or C&B Metabond. The samples were thermal-cycled for 10,000 cycles. They were then immersed in erythrosine solution, sectioned, and observed under a microscope. Microleakage analyses were performed using a 0-4 point system. The data were statistically analyzed. There were significant differences between the coated specimens and the uncoated specimens using Fuji I and Vitremer. The results showed that a resin coating could decrease the amount of marginal leakage when applied with these two cements.

  20. A geometric morphometric study of a Middle Pleistocene cranium from Hexian, China.

    PubMed

    Cui, Yaming; Wu, Xinzhi

    2015-11-01

    The Hexian calvarium is one of the most complete and well-preserved Homo erectus fossils ever found in east Asia, apart from the Zhoukoudian specimens. Various methods bracket the age of the Hexian fossil to between 150 and 412 ka (thousands of years ago). The Hexian calvarium has been considered to be H. erectus given its morphological similarities to Zhoukoudian and Javan H. erectus. However, discussion continues regarding the affinities of the Hexian specimen with other H. erectus fossils. The arguments mainly focus on its relationships to other Asian H. erectus fossils, including those from both China and Java. To better determine the affinities of the Hexian cranium, our study used 3D landmark and semilandmark geometric morphometric techniques and multivariate statistical analyses to quantify the shape of the neurocranium and to compare the Hexian cranium to other H. erectus specimens. The results of this study confirmed the morphological similarities between Hexian and Chinese H. erectus in overall morphology, and particularly in the structure of the frontal bone and the posterior part of the neurocranium. Although the Hexian specimen shows the strongest connection to Chinese H. erectus, the morphology of the lateral neurocranium resembles early Indonesian H. erectus specimens, possibly suggesting shared common ancestry or gene flow from early Indonesian populations. Overall cranial and frontal bone morphology are strongly influenced by geography. Although geographically intermediate between Zhoukoudian and Indonesian H. erectus, the Hexian specimen does not form part of an obvious morphological gradient with regard to overall cranial shape. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Morphometric analyses of hominoid crania, probabilities of conspecificity and an approximation of a biological species constant.

    PubMed

    Thackeray, J F; Dykes, S

    2016-02-01

    Thackeray has previously explored the possibility of using a morphometric approach to quantify the "amount" of variation within species and to assess probabilities of conspecificity when two fossil specimens are compared, instead of "pigeon-holing" them into discrete species. In an attempt to obtain a statistical (probabilistic) definition of a species, Thackeray has recognized an approximation of a biological species constant (T=-1.61) based on the log-transformed standard error of the coefficient m (log sem) in regression analysis of cranial and other data from pairs of specimens of conspecific extant species, associated with regression equations of the form y=mx+c where m is the slope and c is the intercept, using measurements of any specimen A (x axis), and any specimen B of the same species (y axis). The log-transformed standard error of the co-efficient m (log sem) is a measure of the degree of similarity between pairs of specimens, and in this study shows central tendency around a mean value of -1.61 and standard deviation 0.10 for modern conspecific specimens. In this paper we focus attention on the need to take into account the range of difference in log sem values (Δlog sem or "delta log sem") obtained from comparisons when specimen A (x axis) is compared to B (y axis), and secondly when specimen A (y axis) is compared to B (x axis). Thackeray's approach can be refined to focus on high probabilities of conspecificity for pairs of specimens for which log sem is less than -1.61 and for which Δlog sem is less than 0.03. We appeal for the adoption of a concept here called "sigma taxonomy" (as opposed to "alpha taxonomy"), recognizing that boundaries between species are not always well defined. Copyright © 2015 Elsevier GmbH. All rights reserved.

  2. Effects of freezing on white perch Morone americana (Gmelin, 1789): Implications for multivariate morphometrics

    USGS Publications Warehouse

    Kocovsky, Patrick

    2016-01-01

    This study tested the hypothesis that duration of freezing differentially affects whole-body morphometrics of a derived teleost. Whole-body morphometrics are frequently analyzed to test hypotheses of different species, or stocks within a species, of fishes. Specimens used for morphometric analyses are typically fixed or preserved prior to analysis, yet little research has been done on how fixation or preservation methods or duration of preservation of specimens might affect outcomes of multivariate statistical analyses of differences in shape. To determine whether whole-body morphometrics changed as a result of freezing, 23 whole-body morphometrics of age-1 white perch (Morone americana) from western Lake Erie (n = 211) were analyzed immediately after capture, after being held on ice overnight, and after freezing for 100 or 200 days. Discriminant function analysis revealed that all four groups differed significantly from one another (P < 0.0001). The first canonical axis reflected long-axis morphometrics, where there was a clear pattern of positive translation along this axis with duration of preservation. Re-classification analysis demonstrated fish were typically assigned to their original preservation class except for fish frozen 100 days, which assigned mostly to frozen 200 days. Morphometric comparisons using frozen fish must be done on fish frozen for identical periods of time to avoid biases related to the length of time they were frozen. Similar experiments should be conducted on other species and also using formalin- and alcohol-preserved specimens.

  3. A practical and systematic review of Weibull statistics for reporting strengths of dental materials

    PubMed Central

    Quinn, George D.; Quinn, Janet B.

    2011-01-01

    Objectives To review the history, theory and current applications of Weibull analyses sufficient to make informed decisions regarding practical use of the analysis in dental material strength testing. Data References are made to examples in the engineering and dental literature, but this paper also includes illustrative analyses of Weibull plots, fractographic interpretations, and Weibull distribution parameters obtained for a dense alumina, two feldspathic porcelains, and a zirconia. Sources Informational sources include Weibull's original articles, later articles specific to applications and theoretical foundations of Weibull analysis, texts on statistics and fracture mechanics and the international standards literature. Study Selection The chosen Weibull analyses are used to illustrate technique, the importance of flaw size distributions, physical meaning of Weibull parameters and concepts of “equivalent volumes” to compare measured strengths obtained from different test configurations. Conclusions Weibull analysis has a strong theoretical basis and can be of particular value in dental applications, primarily because of test specimen size limitations and the use of different test configurations. Also endemic to dental materials, however, is increased difficulty in satisfying application requirements, such as confirming fracture origin type and diligence in obtaining quality strength data. PMID:19945745

  4. Nondestructive DNA extraction from museum specimens.

    PubMed

    Hofreiter, Michael

    2012-01-01

    Natural history museums around the world hold millions of animal and plant specimens that are potentially amenable to genetic analyses. With more and more populations and species becoming extinct, the importance of these specimens for phylogenetic and phylogeographic analyses is rapidly increasing. However, as most DNA extraction methods damage the specimens, nondestructive extraction methods are useful to balance the demands of molecular biologists, morphologists, and museum curators. Here, I describe a method for nondestructive DNA extraction from bony specimens (i.e., bones and teeth). In this method, the specimens are soaked in extraction buffer, and DNA is then purified from the soaking solution using adsorption to silica. The method reliably yields mitochondrial and often also nuclear DNA. The method has been adapted to DNA extraction from other types of specimens such as arthropods.

  5. Effect of the application of surface treatments before and after sintering on the flexural strength, phase transformation and surface topography of zirconia.

    PubMed

    Kurtulmus-Yilmaz, Sevcan; Aktore, Huseyin

    2018-05-01

    To evaluate the effects of airborne-particle abrasion (APA) and Er,Cr:YSGG laser irradiation on 4-point-flexural strength, phase transformation and morphologic changes of zirconia ceramics treated at pre-sintered or post-sintered stage. Three hundred and forty-two bar shaped zirconia specimens were milled with different sizes according to the flexural strength test (n = 10), X-ray diffraction (XRD) (n = 4) and field emission scanning electron microscope (FE-SEM) (n = 4) analyses. For each test protocol, specimens were divided into 4 main groups whether the surface treatments applied before or after sintering and whether the specimens received heat treatment or not as pre-sintered, post-sintered no-heat and post-sintered heat-treated groups, and a group was served as control. Main groups were further divided into 6 equal subgroups according to surface treatment method applied (2 W-, 3 W-, 4 W-, 5 W-, 6 W-laser irradiations and APA). Surface treatments were applied to pre-sintered groups before sintering and to post-sintered groups after sintering. Post-sintered heat-treated groups were subjected to veneer ceramic firing simulation after surface treatments. Flexural strength and flexural modulus values were statistically analysed and monoclinic phase content was calculated. Weibull analysis was used to evaluate strength reliability and fractographic analysis was conducted. Highest flexural strength values were detected at post-sintered no-heat APA and 4W-laser groups (P < 0.05). Pre-sintered groups showed statistically lower flexural strength values. Heat treatment decreased the strength of the specimens. Monoclinic phase content was only detected at post-sintered no-heat groups and the highest amount was detected at APA group. Rougher surfaces and deeper irregularities were detected at FE-SEM images pre-sintered groups. Application of surface treatments at pre-sintered stage may be detrimental for zirconia ceramics in terms of flexural strength. Treating the surface of zirconia ceramic before sintering process is not recommended due to significant decrease in flexural strength values. 2 W-4 W Er,Cr:YSGG laser irradiations can be regarded as alternative surface treatment methods when zirconia restoration would be subjected to veneer ceramic firing procedures. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Stomatin-like protein 2 is overexpressed in epithelial ovarian cancer and predicts poor patient survival.

    PubMed

    Sun, Fei; Ding, Wen; He, Jie-Hua; Wang, Xiao-Jing; Ma, Ze-Biao; Li, Yan-Fang

    2015-10-20

    Stomatin-like protein 2 (SLP-2, also known as STOML2) is a stomatin homologue of uncertain function. SLP-2 overexpression has been suggested to be associated with cancer progression, resulting in adverse clinical outcomes in patients. Our study aim to investigate SLP-2 expression in epithelial ovarian cancer cells and its correlation with patient survival. SLP-2 mRNA and protein expression levels were analysed in five epithelial ovarian cancer cell lines and normal ovarian epithelial cells using real-time PCR and western blotting analysis. SLP-2 expression was investigated in eight matched-pair samples of epithelial ovarian cancer and adjacent noncancerous tissues from the same patients. Using immunohistochemistry, we examined the protein expression of paraffin-embedded specimens from 140 patients with epithelial ovarian cancer, 20 cases with borderline ovarian tumours, 20 cases with benign ovarian tumours, and 20 cases with normal ovarian tissues. Statistical analyses were applied to evaluate the clinicopathological significance of SLP-2 expression. SLP-2 mRNA and protein expression levels were significantly up-regulated in epithelial ovarian cancer cell lines and cancer tissues compared with normal ovarian epithelial cells and adjacent noncancerous ovarian tissues. Immunohistochemistry analysis revealed that the relative overexpression of SLP-2 was detected in 73.6 % (103/140) of the epithelial ovarian cancer specimens, 45.0 % (9/20) of the borderline ovarian specimens, 30.0 % (6/20) of the benign ovarian specimens and none of the normal ovarian specimens. SLP-2 protein expression in epithelial ovarian cancer was significantly correlated with the tumour stage (P < 0.001). Epithelial ovarian cancer patients with higher SLP-2 protein expression levels had shorter progress free survival and overall survival times compared to patients with lower SLP-2 protein expression levels. Multivariate analyses showed that SLP-2 expression levels were an independent prognostic factor for survival in epithelial ovarian cancer patients. SLP-2 mRNA and proteins were overexpressed in epithelial ovarian cancer tissues. SLP-2 protein overexpression was associated with advanced stage disease. Patients with higher SLP-2 protein expression had shorter progress free survival and poor overall survival times. Thus, SLP-2 protein expression was an independent prognostic factor for patients with epithelial ovarian cancer.

  7. Color stability comparison of silicone facial prostheses following disinfection.

    PubMed

    Goiato, Marcelo Coelho; Pesqueira, Aldiéris Alves; dos Santos, Daniela Micheline; Zavanelli, Adriana Cristina; Ribeiro, Paula do Prado

    2009-04-01

    The purpose of this study was to evaluate the color stability of two silicones for use in facial prostheses, under the influence of chemical disinfection and storage time. Twenty-eight specimens were obtained half made from Silastic MDX 4-4210 silicone and the other half from Silastic 732 RTV silicone. The specimens were divided into four groups: Silastic 732 RTV and MDX 4-4210 with disinfection three times a week with Efferdent and Sliastic 732 RTV and MDX 4-4210 disinfected with neutral soap. Color stability was analyzed by spectrophotometry, immediately and 2 months after making the specimens. After obtaining the results, ANOVA and Tukey test with 1% reliability were used for statistical analysis. Statistical differences between mean color values were observed. Disinfection with Efferdent did not statistically influence the mean color values. The factors of storage time and disinfection statistically influenced color stability; disinfection acts as a bleaching agent in silicone materials.

  8. Color stability of nanocomposites polished with one-step systems.

    PubMed

    Ergücü, Zeynep; Türkün, L Sebnem; Aladag, Akin

    2008-01-01

    This study compared the color changes of five novel resin composites polished with two one-step polishing systems when exposed to coffee solution. The resin composites tested were Filtek Supreme XT, Grandio, CeramX, Premise and Tetric EvoCeram. A total of 150 discs (30/resin composites, 10 x 2 mm) were fabricated. Ten specimens/resin composites cured under Mylar strips served as the control. The other samples were polished with PoGo and OptraPol discs for 30 seconds using a slow speed handpiece and immersed in coffee (Nescafé) for seven days. Color measurements were made with Vita Easyshade at baseline and after one and seven days. Repeated Measures ANOVA and Bonferroni tests were used for statistical analyses (p< or =0.05). The differences between the mean DeltaE* values for the resin composites polished with two different one-step systems were statistically significant (p<0.05). After one week, all materials exhibited significant color changes compared to baseline. All Mylar finished specimens showed the most intense staining (p<0.05). There were no significant differences between the OptraPol and PoGo polished groups. Mylar-finished specimens of CeramX, Tetric EvoCeram, Premise and Filtek Supreme XT presented the greatest staining (p<0.05). For Grandio, there were no significant differences between the Mylar and PoGo groups, while the most stain resistant surfaces were attained with OptraPol. Removing the outermost resin layer by polishing procedures is essential to achieving a stain resistant, more esthetically stable surface. One-step polishing systems can be used successfully for polishing nanocomposites.

  9. The study of the oipA and dupA genes in Helicobacter pylori strains and their relationship with different gastroduodenal diseases

    PubMed Central

    Souod, Negar; Sarshar, Meysam; Dabiri, Hossein; Momtaz, Hassan; Kargar, Mohammad; Mohammadzadeh, Alireza; Abdi, Saeed

    2015-01-01

    Aim: The purpose of this investigation was to determine the oipA and dupA genes of Helicobacter pylori isolates from west of Iran; Chaharmahalo Bakhtiyari region and find their relationship with the severity of the gastroduodenal diseases. Background: Helicobacter pylori is an organism responsible for many gastroduodenal diseases. Many studies suggest that genetic diversity in H. pylori virulence factors such as oipA and dupA genes is high among isolates of different geographic regions and may cause more severe diseases. Patients and methods: In this cross-sectional study, gastric biopsy specimens were taken from 150 patients suffering from gastroduodenal diseases. The presence of ureC, dupA and oipA genes was tested by polymerase chain reaction (PCR). Results: Overall, 123 (82%) H. pylori strains were isolated from 150 specimens. dupA gene was detected in 41 (33.33%) H.pylori-positive specimens. There was a reverse correlation between this gene and gastric cancer. The oipA gene was found in 88 (71.54%) samples and statistically there was no association between this gene and gastric disorders. As statistical analyses revealed, the presence of the dupA was more common in isolates with the oipA negative. Conclusion: Based on our findings, the presence of dupA gene can be considered as a marker for the onset of severe diseases. However, the oipA gene cannot be regarded for prediction of gastroenterology diseases. Meanwhile, extended molecular epidemiology researches in other populations are recommended. PMID:26171137

  10. Evaluation of specimen preparation techniques for micro-PIXE localisation of elements in hyperaccumulating plants

    NASA Astrophysics Data System (ADS)

    Kachenko, Anthony G.; Siegele, Rainer; Bhatia, Naveen P.; Singh, Balwant; Ionescu, Mihail

    2008-04-01

    Hybanthus floribundus subsp. floribundus, a rare Australian Ni-hyperaccumulating shrub and Pityrogramma calomelanos var. austroamericana, an Australian naturalized As-hyperaccumulating fern are promising species for use in phytoremediation of contaminated sites. Micro-proton-induced X-ray emission (μ-PIXE) spectroscopy was used to map the elemental distribution of the accumulated metal(loid)s, Ca and K in leaf or pinnule tissues of the two plant species. Samples were prepared by two contrasting specimen preparation techniques: freeze-substitution in tetrahydrofuran (THF) and freeze-drying. The specimens were analysed to compare the suitability of each technique in preserving (i) the spatial elemental distribution and (ii) the tissue structure of the specimens. Further, the μ-PIXE results were compared with concentration of elements in the bulk tissue obtained by ICP-AES analysis. In H. floribundus subsp. floribundus, μ-PIXE analysis revealed Ni, Ca and K concentrations in freeze-dried leaf tissues were at par with bulk tissue concentrations. Elemental distribution maps illustrated that Ni was preferentially localised in the adaxial epidermal tissues (1% DW) and least concentration was found in spongy mesophyll tissues (0.53% DW). Conversely, elemental distribution maps of THF freeze-substituted tissues indicated significantly lower Ni, Ca and K concentrations than freeze-dried specimens and bulk tissue concentrations. Moreover, Ni concentrations were uniform across the whole specimen and no localisation was observed. In P. calomelanos var. austroamericana freeze-dried pinnule tissues, μ-PIXE revealed statistically similar As, Ca and K concentrations as compared to bulk tissue concentrations. Elemental distribution maps showed that As localisation was relatively uniform across the whole specimen. Once again, THF freeze-substituted tissues revealed a significant loss of As compared to freeze-dried specimens and the concentrations obtained by bulk tissue analysis. The results demonstrate that freeze-drying is a suitable sample preparation technique to study elemental distribution of ions in H. floribundus and P. calomelanos plant tissues using μ-PIXE spectroscopy. Furthermore, cellular structure was preserved in samples prepared using this technique.

  11. Anatomy of the proximal tibiofibular joint and interosseous membrane, and their contributions to joint kinematics in below-knee amputations.

    PubMed

    Burkhart, Timothy A; Asa, Benjamin; Payne, Michael W C; Johnson, Marjorie; Dunning, Cynthia E; Wilson, Timothy D

    2015-02-01

    A result of below-knee amputations (BKAs) is abnormal motion that occurs about the proximal tibiofibular joint (PTFJ). While it is known that joint morphology may play a role in joint kinematics, this is not well understood with respect to the PTFJ. Therefore, the purposes of this study were: (i) to characterize the anatomy of the PTFJ and statistically analyze the relationships within the joint; and (ii) to determine the relationships between the PTFJ characteristics and the degree of movement of the fibula in BKAs. The PTFJ was characterized in 40 embalmed specimens disarticulated at the knee, and amputated through the mid-tibia and fibula. Four metrics were measured: inclination angle (angle at which the fibula articulates with the tibia); tibial and fibular articular surface areas; articular surface concavity and shape. The specimens were mechanically tested by applying a load through the biceps femoris tendon, and the degree of motion about the tibiofibular joint was measured. Regression analyses were performed to determine the relationships between the different PTFJ characteristics and the magnitude of fibular abduction. Finally, Pearson correlation analyses were performed on inclination angle and surface area vs. fibular kinematics. The inclination angle measured on the fibula was significantly greater than that measured on the tibia. This difference may be attributed to differences in concavity of the tibial and fibular surfaces. Surface area measured on the tibia and fibula was not statistically different. The inclination angle was not statistically correlated to surface area. However, when correlating fibular kinematics in BKAs, inclination angle was positively correlated to the degree of fibular abduction, whereas surface area was negatively correlated. The characteristics of the PTFJ dictate the amount of fibular movement, specifically, fibular abduction in BKAs. Predicting BKA complications based on PTFJ characteristics can lead to recommendations in treatment. © 2014 Anatomical Society.

  12. Comparison of estrogen receptor results from pathology reports with results from central laboratory testing.

    PubMed

    Collins, Laura C; Marotti, Jonathan D; Baer, Heather J; Tamimi, Rulla M

    2008-02-06

    We compared estrogen receptor (ER) assay results abstracted from pathology reports with ER results determined on the same specimens by a central laboratory with an immunohistochemical assay. Paraffin sections were cut from tissue microarrays containing 3093 breast cancer specimens from women enrolled in the Nurses' Health Study, 1851 of which had both pathology reports and tissue available for central laboratory testing. All sections were immunostained for ER at the same time. The original assays were biochemical for 1512 (81.7%) of the 1851 specimens, immunohistochemical for 336 (18.2%), and immunofluorescent for three (0.2%). ER results from pathology reports and repeat central laboratory testing were in agreement for 87.3% of specimens (1615 of the 1851 specimens; kappa statistic = 0.64, P < .001). When the comparison was restricted to the specimens for which the ER assays were originally performed by immunohistochemistry, the agreement rate increased to 92.3% of specimens (310 of the 336 specimens; kappa statistic = 0.78, P < .001). Thus, ER assay results from pathology reports appear to be a reasonable alternative to central laboratory ER testing for large, population-based studies of patients with breast cancer.

  13. A study of environmental characterization of conventional and advanced aluminum alloys for selection and design. Phase 2: The breaking load test method

    NASA Technical Reports Server (NTRS)

    Sprowls, D. O.; Bucci, R. J.; Ponchel, B. M.; Brazill, R. L.; Bretz, P. E.

    1984-01-01

    A technique is demonstrated for accelerated stress corrosion testing of high strength aluminum alloys. The method offers better precision and shorter exposure times than traditional pass fail procedures. The approach uses data from tension tests performed on replicate groups of smooth specimens after various lengths of exposure to static stress. The breaking strength measures degradation in the test specimen load carrying ability due to the environmental attack. Analysis of breaking load data by extreme value statistics enables the calculation of survival probabilities and a statistically defined threshold stress applicable to the specific test conditions. A fracture mechanics model is given which quantifies depth of attack in the stress corroded specimen by an effective flaw size calculated from the breaking stress and the material strength and fracture toughness properties. Comparisons are made with experimental results from three tempers of 7075 alloy plate tested by the breaking load method and by traditional tests of statistically loaded smooth tension bars and conventional precracked specimens.

  14. Hydrostatic Stress Effects in Metal Plasticity

    NASA Technical Reports Server (NTRS)

    Wilson, Christopher D.

    1999-01-01

    Since the 1940s, the theory of plasticity has assumed that hydrostatic stress does not affect the yield or postyield behavior of metals. This assumption is based on the early work of Bridgman. Bridgman found that hydrostatic pressure (compressive stress) does not affect yield behavior until a substantial amount of pressure (greater than 100 ksi) is present. The objective of this study was to determine the effect of hydrostatic tension on yield behavior. Two different specimen geometries were examined: an equal-arm bend specimen and a double edge notch specimen. The presence of a notch is sufficient to develop high enough hydrostatic tensile stresses to affect yield. The von Mises yield function, which does not have a hydrostatic component, and the Drucker-Prager yield function, which includes a hydrostatic component, were used in finite element analyses of the two specimen geometries. The analyses were compared to test data from IN 100 specimens. For both geometries, the analyses using the Drucker-Prager yield function more closely simulated the test data. The von Mises yield function lead to 5-10% overprediction of the force-displacement or force-strain response of the test specimens.

  15. Statistical investigation of fatigue crack initiation and growth around chamfered rivet holes in Alclad 2024 T3 as affected by corrosion

    NASA Technical Reports Server (NTRS)

    Fadragas, M. I.; Fine, M. E.; Moran, B.

    1994-01-01

    In panel specimens with rivet holes cracks initiate in the blunted knife edge of the chamfered rivet hole and propagate inward as well as along the hole. The fatigue lifetime to dominant crack information was defined as the number of cycles, N500 micrometer, to formation of a 500 micrometer long crack. Statistical data on N500 micrometer and on crack propagation after N500 micrometer were obtained for a large number of uncorroded specimens and specimens corroded in an ASTM B 117 salt spray. Considerable variation in N500 micrometer and crack propagation behavior was observed from specimen to specimen of the same nominal geometry with chamfered rivet holes increased the probability for both early formation and later formation of a propagating 500 micrometer fatigue crack. The growth of fatigue cracks after 500 micrometer size was little affected by prior salt spray.

  16. Effects of Different Surface Treatment Methods and MDP Monomer on Resin Cementation of Zirconia Ceramics an In Vitro Study.

    PubMed

    Tanış, Merve Çakırbay; Akçaboy, Cihan

    2015-01-01

    Resin cements are generally preferred for cementation of zirconia ceramics. Resin bonding of zirconia ceramics cannot be done with the same methods of traditional ceramics because zirconia is a silica-free material. In recent years, many methods have been reported in the literature to provide the resin bonding of zirconia ceramics. The purpose of this in vitro study is to evaluate effects of different surface treatments and 10-metacryloxydecyl dihydrogen phosphate (MDP) monomer on shear bond strength between zirconia and resin cement. 120 zirconia specimens were treated as follows: Group I: sandblasting, group II: sandblasting + tribochemical silica coating + silane, group III: sandblasting + Nd:YAG (neodymium: yttrium-aluminum-garnet) laser. One specimen from each group was evaluated under scanning electron microscope (SEM). Specimens in each group were bonded either with conventional resin cement Variolink II or with a MDP containing resin cement Panavia F2.0. Subgroups of bonded specimens were stored in distilled water (37°C) for 24 hours or 14 days. Following water storage shear bond strength test was performed at a crosshead speed of 1 mm/min in a universal test machine. Then statistical analyses were performed. Highest shear bond strength values were observed in group II. No significant difference between group I and III was found when Panavia F2.0 resin cement was used. When Variolink II resin cement was used group III showed significantly higher bond strength than group I. In group I, Panavia F2.0 resin cement showed statistically higher shear bond strength than Variolink II resin cement. In group II no significant difference was found between resin cements. No significant difference was found between specimens stored in 37°C distilled water for 24 hours and 14 days. In group I surface irregularities with sharp edges and grooves were observed. In group II less roughened surface was observed with silica particles. In group III surface microcracks connecting each other were observed. Tribochemical silica coating is an effective method for achieving an acceptable bond between zirconia and resin cement. Use of a MDP monomer containing resin cement increases the bond strength of sandblasted zirconia.

  17. Hygroscopic expansion of self-adhesive resin cements and the integrity of all-ceramic crowns.

    PubMed

    Kirsten, Magdalena; Matta, Ragai Edward; Belli, Renan; Lohbauer, Ulrich; Wichmann, Manfred; Petschelt, Anselm; Zorzin, José

    2018-04-27

    Low pH neutralization and subsequent remnant hydrophilicity can lead to hygroscopic expansion of self-adhesive resin cements (SARCs) after water storage. The aim of this in vitro study was to investigate the effects of hygroscopic expansion of SARCs, used as luting and partial core build-up material, on integrity and cement gap thickness increase of all-ceramic CAD/CAM crowns. Human third molars (n=48) were prepared and anatomical all-ceramic CAD/CAM crowns were manufactured (VITABLOCS Mark II, VITA Zahnfabrik). Crowns internal surfaces were HF etched and silanized. The prepared teeth with their respective crowns were divided into 6 groups (n=8). In groups 1, 3 and 5 the coronal dentin was removed to simulate a partial core build-up. Groups 1 and 2 were luted with iCEM (Heraeus Kulzer), 3 and 4 with RelyX Unicem 2 Automix (3M), 5 and 6 with Variolink Esthetic DC (Ivoclar Vivadent). All specimens were dual cured and stored in distilled water at 37°C. Crown integrity was controlled at baseline and in regular intervals until 180 days. Cement gap thickness was measured using an optical 3D scanner (ATOS Triple scan, GOM) at baseline and after 180 days. Crown integrity was statistically analysed using Kaplan-Meier survival analysis and cement gap thickness increase using two-way ANOVA (α=0.05). After 180 days storage, crack formation was observed in all specimens of group 1 (mean survival time of 85.5 days), in one specimen of group 2 and in two specimens of group 4. Two-way ANOVA analysis revealed a statistically significant interaction between material type and build-up on cement gap size increase for iCEM. Within the limits of this study, the application of SARCs with low pH neutralization as partial build-up material under CAD/CAM crowns is not recommended for clinical use. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.

  18. Patient safety in the clinical laboratory: a longitudinal analysis of specimen identification errors.

    PubMed

    Wagar, Elizabeth A; Tamashiro, Lorraine; Yasin, Bushra; Hilborne, Lee; Bruckner, David A

    2006-11-01

    Patient safety is an increasingly visible and important mission for clinical laboratories. Attention to improving processes related to patient identification and specimen labeling is being paid by accreditation and regulatory organizations because errors in these areas that jeopardize patient safety are common and avoidable through improvement in the total testing process. To assess patient identification and specimen labeling improvement after multiple implementation projects using longitudinal statistical tools. Specimen errors were categorized by a multidisciplinary health care team. Patient identification errors were grouped into 3 categories: (1) specimen/requisition mismatch, (2) unlabeled specimens, and (3) mislabeled specimens. Specimens with these types of identification errors were compared preimplementation and postimplementation for 3 patient safety projects: (1) reorganization of phlebotomy (4 months); (2) introduction of an electronic event reporting system (10 months); and (3) activation of an automated processing system (14 months) for a 24-month period, using trend analysis and Student t test statistics. Of 16,632 total specimen errors, mislabeled specimens, requisition mismatches, and unlabeled specimens represented 1.0%, 6.3%, and 4.6% of errors, respectively. Student t test showed a significant decrease in the most serious error, mislabeled specimens (P < .001) when compared to before implementation of the 3 patient safety projects. Trend analysis demonstrated decreases in all 3 error types for 26 months. Applying performance-improvement strategies that focus longitudinally on specimen labeling errors can significantly reduce errors, therefore improving patient safety. This is an important area in which laboratory professionals, working in interdisciplinary teams, can improve safety and outcomes of care.

  19. Error in geometric morphometric data collection: Combining data from multiple sources.

    PubMed

    Robinson, Chris; Terhune, Claire E

    2017-09-01

    This study compares two- and three-dimensional morphometric data to determine the extent to which intra- and interobserver and intermethod error influence the outcomes of statistical analyses. Data were collected five times for each method and observer on 14 anthropoid crania using calipers, a MicroScribe, and 3D models created from NextEngine and microCT scans. ANOVA models were used to examine variance in the linear data at the level of genus, species, specimen, observer, method, and trial. Three-dimensional data were analyzed using geometric morphometric methods; principal components analysis was employed to examine how trials of all specimens were distributed in morphospace and Procrustes distances among trials were calculated and used to generate UPGMA trees to explore whether all trials of the same individual grouped together regardless of observer or method. Most variance in the linear data was at the genus level, with greater variance at the observer than method levels. In the 3D data, interobserver and intermethod error were similar to intraspecific distances among Callicebus cupreus individuals, with interobserver error being higher than intermethod error. Generally, taxa separate well in morphospace, with different trials of the same specimen typically grouping together. However, trials of individuals in the same species overlapped substantially with one another. Researchers should be cautious when compiling data from multiple methods and/or observers, especially if analyses are focused on intraspecific variation or closely related species, as in these cases, patterns among individuals may be obscured by interobserver and intermethod error. Conducting interobserver and intermethod reliability assessments prior to the collection of data is recommended. © 2017 Wiley Periodicals, Inc.

  20. Final Report: Posttest Analysis of Omega II Optical Specimens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Newlander, C D; Fisher, J H

    Preliminary posttest analyses have been completed on optical specimens exposed during the Omega II test series conducted on 14 July 2006. The Omega Facility, located at the Laboratory for Laser Energetics (LLE) at the University of Rochester was used to produce X-ray environments through the interaction of intense pulsed laser radiation upon germanium-loaded silica aerogels. The optical specimen testing was supported by GH Systems through experiment design, pre- and post-test analyses, specimen acquisition, and overall technical experience. The test specimens were fabricated and characterized by Surface Optics Corporation (SOC), San Diego, CA and were simple protected gold coatings on silicamore » substrates. Six test specimens were exposed, five filtered with thin beryllium foil filters, and one unfiltered which was exposed directly to the raw environment. The experimental objectives were: (1) demonstrate that tests of optical specimens could be performed at the Omega facility; (2) evaluate the use and survivability of beryllium foil filters as a function of thickness; (3) obtain damage data on optical specimens which ranged from no damage to damage; (4) correlate existing thermal response models with the damage data; (5) evaluate the use of the direct raw environment upon the specimen response and the ability/desirability to conduct sensitive optical specimen tests using the raw environment; and (6) initiate the development of a protocol for performing optical coatings/mirror tests. This report documents the activities performed by GH Systems in evaluating and using the environments provided by LLNL, the PUFFTFT analyses performed using those environments, and the calculated results compared to the observed and measured posttest data.« less

  1. Proliferative changes in the bronchial epithelium of former smokers treated with retinoids.

    PubMed

    Hittelman, Walter N; Liu, Diane D; Kurie, Jonathan M; Lotan, Reuben; Lee, Jin Soo; Khuri, Fadlo; Ibarguen, Heladio; Morice, Rodolfo C; Walsh, Garrett; Roth, Jack A; Minna, John; Ro, Jae Y; Broxson, Anita; Hong, Waun Ki; Lee, J Jack

    2007-11-07

    Retinoids have shown antiproliferative and chemopreventive activity. We analyzed data from a randomized, placebo-controlled chemoprevention trial to determine whether a 3-month treatment with either 9-cis-retinoic acid (RA) or 13-cis-RA and alpha-tocopherol reduced Ki-67, a proliferation biomarker, in the bronchial epithelium. Former smokers (n = 225) were randomly assigned to receive 3 months of daily oral 9-cis-RA (100 mg), 13-cis-RA (1 mg/kg) and alpha-tocopherol (1200 IU), or placebo. Bronchoscopic biopsy specimens obtained before and after treatment were immunohistochemically assessed for changes in the Ki-67 proliferative index (i.e., percentage of cells with Ki-67-positive nuclear staining) in the basal and parabasal layers of the bronchial epithelium. Per-subject and per-biopsy site analyses were conducted. Multicovariable analyses, including a mixed-effects model and a generalized estimating equations model, were used to investigate the treatment effect (Ki-67 labeling index and percentage of bronchial epithelial biopsy sites with a Ki-67 index > or = 5%) with adjustment for multiple covariates, such as smoking history and metaplasia. Coefficient estimates and 95% confidence intervals (CIs) were obtained from the models. All statistical tests were two-sided. In per-subject analyses, Ki-67 labeling in the basal layer was not changed by any treatment; the percentage of subjects with a high Ki-67 labeling in the parabasal layer dropped statistically significantly after treatment with 13-cis-RA and alpha-tocopherol treatment (P = .04) compared with placebo, but the drop was not statistically significant after 9-cis-RA treatment (P = .17). A similar effect was observed in the parabasal layer in a per-site analysis; the percentage of sites with high Ki-67 labeling dropped statistically significantly after 9-cis-RA treatment (coefficient estimate = -0.72, 95% CI = -1.24 to -0.20; P = .007) compared with placebo, and after 13-cis-RA and alpha-tocopherol treatment (coefficient estimate = -0.66, 95% CI = -1.15 to -0.17; P = .008). In per-subject analyses, treatment with 13-cis-RA and alpha-tocopherol, compared with placebo, was statistically significantly associated with reduced bronchial epithelial cell proliferation; treatment with 9-cis-RA was not. In per-site analyses, statistically significant associations were obtained with both treatments.

  2. Proliferative Changes in the Bronchial Epithelium of Former Smokers Treated With Retinoids

    PubMed Central

    Hittelman, Walter N.; Liu, Diane D.; Kurie, Jonathan M.; Lotan, Reuben; Lee, Jin Soo; Khuri, Fadlo; Ibarguen, Heladio; Morice, Rodolfo C.; Walsh, Garrett; Roth, Jack A.; Minna, John; Ro, Jae Y.; Broxson, Anita; Hong, Waun Ki; Lee, J. Jack

    2012-01-01

    Background Retinoids have shown antiproliferative and chemopreventive activity. We analyzed data from a randomized, placebo-controlled chemoprevention trial to determine whether a 3-month treatment with either 9-cis-retinoic acid (RA) or 13-cis-RA and α-tocopherol reduced Ki-67, a proliferation biomarker, in the bronchial epithelium. Methods Former smokers (n = 225) were randomly assigned to receive 3 months of daily oral 9-cis-RA (100 mg), 13-cis-RA (1 mg/kg) and α-tocopherol (1200 IU), or placebo. Bronchoscopic biopsy specimens obtained before and after treatment were immunohistochemically assessed for changes in the Ki-67 proliferative index (i.e., percentage of cells with Ki-67–positive nuclear staining) in the basal and parabasal layers of the bronchial epithelium. Per-subject and per–biopsy site analyses were conducted. Multicovariable analyses, including a mixed-effects model and a generalized estimating equations model, were used to investigate the treatment effect (Ki-67 labeling index and percentage of bronchial epithelial biopsy sites with a Ki-67 index ≥ 5%) with adjustment for multiple covariates, such as smoking history and metaplasia. Coefficient estimates and 95% confidence intervals (CIs) were obtained from the models. All statistical tests were two-sided. Results In per-subject analyses, Ki-67 labeling in the basal layer was not changed by any treatment; the percentage of subjects with a high Ki-67 labeling in the parabasal layer dropped statistically significantly after treatment with 13-cis-RA and α-tocopherol treatment (P = .04) compared with placebo, but the drop was not statistically significant after 9-cis-RA treatment (P = .17). A similar effect was observed in the parabasal layer in a per-site analysis; the percentage of sites with high Ki-67 labeling dropped statistically significantly after 9-cis-RA treatment (coefficient estimate = −0.72, 95% CI = −1.24 to −0.20; P = .007) compared with placebo, and after 13-cis-RA and α-tocopherol treatment (coefficient estimate = −0.66, 95% CI = −1.15 to −0.17; P = .008). Conclusions In per-subject analyses, treatment with 13-cis-RA and α-tocopherol, compared with placebo, was statistically significantly associated with reduced bronchial epithelial cell proliferation; treatment with 9-cis-RA was not. In per-site analyses, statistically significant associations were obtained with both treatments. PMID:17971525

  3. Histologic assessment of thermal injury to tonsillectomy specimens: a comparison of electrocautery, coblation, harmonic scalpel, and tonsillotome.

    PubMed

    Modi, Vikash K; Monforte, Hector; Geller, Kenneth A; Koempel, Jeffrey A

    2009-11-01

    To determine the extent of thermal injury to the tonsillar tissue following the use of various types of instrumentation. To determine if tonsillectomy specimens routinely contain tissue other than lymphoid tissue. Retrospective histologic analysis. A histologic analysis performed on 228 tonsillectomy specimens removed by use of an electrocautery in 132 specimens, harmonic scalpel in 46, coblation device in 24, and a tonsillotome in 26. The specimens were evaluated for presence and percentage of skeletal muscle and depth of thermal tissue injury. The mean percentage of skeletal muscle present in the specimens was 0.79% for electrocautery, 1.74% for harmonic scalpel, 0.97% for coblation device, and 1.66% for the tonsillotome. Skeletal muscle was absent in only 8 of 228 specimens (3.5%). Electrocautery has a statistically significant (P < .05) lower percentage of muscle tissue compared to harmonic scalpel and the tonsillotome. There was no statistically significant difference in the mean depth of thermal injury among the harmonic scalpel (0.68 mm), electrocautery (0.58 mm), and coblation device (0.71 mm) specimens. The tonsillotome specimens had no thermal injury. Attempts to remove the entire tonsil results in a similar depth of thermal injury to tonsillectomy specimens when using the harmonic scalpel, electrocautery, and coblation device. Skeletal muscle is a nearly ubiquitous finding in routine tonsillectomy specimens. The use of an electrocautery with a needle point may allow for a more precise dissection as it results in tonsillectomy specimens with a smaller percentage of muscle present.

  4. Evaluation of the BD Vacutainer Plus Urine C&S Preservative Tubes compared with nonpreservative urine samples stored at 4°C and room temperature.

    PubMed

    Eisinger, Stephen W; Schwartz, Matthew; Dam, Lisa; Riedel, Stefan

    2013-09-01

    The stability of urine specimens submitted for culture remains a challenge for many laboratories because of delays in specimen transport. We evaluated the usefulness of BD Vacutainer Plus Urine C&S Preservative Tube in ensuring specimen stability. Clinical urine specimens collected in sterile collection cups (n = 110) were plated onto sheep blood and MacConkey agar following standard laboratory procedures guidelines. Thereafter, specimens were divided into 3 storage conditions: nonpreservative, refrigerated; nonpreservative, room temperature (RT); BD Vacutainer Plus Urine C&S Preservative Tube, RT. For each sample type, additional cultures were set up at 2, 4, 24, and 48 hours. Initially, 18 specimens had no growth, 32 showed mixed skin flora, and 60 yielded at least 1 uropathogen. Increased colony counts of uropathogens were observed for nonpreserved urine samples stored at RT; these changes were statistically significant. Minor differences between refrigerated urine samples and BD Vacutainer Plus Urine C&S Preservative Tube samples were seen but were not statistically significant. The use of preservative-containing collection tubes is desirable to ensure specimen stability when prompt processing or refrigeration is not feasible.

  5. Tumoural specimens for forensic purposes: comparison of genetic alterations in frozen and formalin-fixed paraffin-embedded tissues.

    PubMed

    Ananian, Viviana; Tozzo, Pamela; Ponzano, Elena; Nitti, Donato; Rodriguez, Daniele; Caenazzo, Luciana

    2011-05-01

    In certain circumstances, tumour tissue specimens are the only DNA resource available for forensic DNA analysis. However, cancer tissues can show microsatellite instability and loss of heterozygosity which, if concerning the short tandem repeats (STRs) used in the forensic field, can cause misinterpretation of the results. Moreover, though formalin-fixed paraffin-embedded tissues (FFPET) represent a large resource for these analyses, the quality of the DNA obtained from this kind of specimen can be an important limit. In this study, we evaluated the use of tumoural tissue as biological material for the determination of genetic profiles in the forensic field, highlighting which STR polymorphisms are more susceptible to tumour genetic alterations and which of the analysed tumours show a higher genetic variability. The analyses were conducted on samples of the same tissues conserved in different storage conditions, to compare genetic profiles obtained by frozen tissues and formalin-fixed paraffin-embedded tissues. The importance of this study is due to the large number of specimens analysed (122), the large number of polymorphisms analysed for each specimen (39), and the possibility to compare, many years after storage, the same tissue frozen and formalin-fixed paraffin-embedded. In the comparison between the genetic profiles of frozen tumour tissues and FFPET, the same genetic alterations have been reported in both kinds of specimens. However, FFPET showed new alterations. We conclude that the use of FFPET requires greater attention than frozen tissues in the results interpretation and great care in both pre-extraction and extraction processes.

  6. Study of deformation evolution during failure of rock specimens using laser-based vibration measurements

    NASA Astrophysics Data System (ADS)

    Smolin, I. Yu.; Kulkov, A. S.; Makarov, P. V.; Tunda, V. A.; Krasnoveikin, V. A.; Eremin, M. O.; Bakeev, R. A.

    2017-12-01

    The aim of the paper is to analyze experimental data on the dynamic response of the marble specimen in uniaxial compression. To make it we use the methods of mathematical statistics. The lateral surface velocity evolution obtained by the laser Doppler vibrometer represents the data for analysis. The registered data were regarded as a time series that reflects deformation evolution of the specimen loaded up to failure. The revealed changes in statistical parameters were considered as precursors of failure. It is shown that before failure the deformation response is autocorrelated and reflects the states of dynamic chaos and self-organized criticality.

  7. CompareTests-R package

    Cancer.gov

    CompareTests is an R package to estimate agreement and diagnostic accuracy statistics for two diagnostic tests when one is conducted on only a subsample of specimens. A standard test is observed on all specimens.

  8. Tensile strength of laser welded cobalt-chromium alloy with and without an argon atmosphere.

    PubMed

    Tartari, Anna; Clark, Robert K F; Juszczyk, Andrzej S; Radford, David R

    2010-06-01

    The tensile strength and depth of weld of two cobalt chromium alloys before and after laser welding with and without an argon gas atmosphere were investigated. Using two cobalt chromium alloys, rod shaped specimens (5 cm x 1.5 mm) were cast. Specimens were sand blasted, sectioned and welded with a pulsed Nd: YAG laser welding machine and tested in tension using an Instron universal testing machine. A statistically significant difference in tensile strength was observed between the two alloys. The tensile strength of specimens following laser welding was significantly less than the unwelded controls. Scanning electron microscopy showed that the micro-structure of the cast alloy was altered in the region of the weld. No statistically significant difference was found between specimens welded with or without an argon atmosphere.

  9. Statistical approaches for the determination of cut points in anti-drug antibody bioassays.

    PubMed

    Schaarschmidt, Frank; Hofmann, Matthias; Jaki, Thomas; Grün, Bettina; Hothorn, Ludwig A

    2015-03-01

    Cut points in immunogenicity assays are used to classify future specimens into anti-drug antibody (ADA) positive or negative. To determine a cut point during pre-study validation, drug-naive specimens are often analyzed on multiple microtiter plates taking sources of future variability into account, such as runs, days, analysts, gender, drug-spiked and the biological variability of un-spiked specimens themselves. Five phenomena may complicate the statistical cut point estimation: i) drug-naive specimens may contain already ADA-positives or lead to signals that erroneously appear to be ADA-positive, ii) mean differences between plates may remain after normalization of observations by negative control means, iii) experimental designs may contain several factors in a crossed or hierarchical structure, iv) low sample sizes in such complex designs lead to low power for pre-tests on distribution, outliers and variance structure, and v) the choice between normal and log-normal distribution has a serious impact on the cut point. We discuss statistical approaches to account for these complex data: i) mixture models, which can be used to analyze sets of specimens containing an unknown, possibly larger proportion of ADA-positive specimens, ii) random effects models, followed by the estimation of prediction intervals, which provide cut points while accounting for several factors, and iii) diagnostic plots, which allow the post hoc assessment of model assumptions. All methods discussed are available in the corresponding R add-on package mixADA. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Shear bond strength of orthodontic color-change adhesives with different light-curing times

    PubMed Central

    Bayani, Shahin; Ghassemi, Amirreza; Manafi, Safa; Delavarian, Mohadeseh

    2015-01-01

    Background: The purpose of this study was to evaluate the effect of light-curing time on the shear bond strength (SBS) of two orthodontic color-change adhesives (CCAs). Materials and Methods: A total of 72 extracted premolars were randomly assigned into 6 groups of 12 teeth each. Subsequent to primer application, a metal bracket was bonded to the buccal surface using an orthodontic adhesive. Two CCAs (Greengloo and Transbond Plus) were tested and one conventional light-cured adhesive (Resilience) served as control. For each adhesive, the specimens were light-cured for two different times of 20 and 40 s. All the specimens underwent mechanical testing using a universal testing machine to measure the SBS. Adhesive remnant index (ARI) was used to assess the remnant adhesive material on the tooth surface. All statistical analyses were performed using SPSS software. The significance level for all statistical tests was set at P ≤ 0.05. Results: The SBSs of the tested groups were in the range of 14.05-31.25 MPa. Greengloo adhesive showed the highest SBS values when light-cured for 40 s, and Transbond Plus adhesive showed the lowest values when light-cured for 20 s. ARI scores of Transbond Plus adhesive were significantly higher than those of controls, while other differences in ARI values were not significant. Conclusion: Within the limitations of his study, decreasing the light-curing time from 40 to 20 s decreased the SBS of the tested adhesives; however, this decline in SBS was statistically significant only in Transbond Plus adhesive PMID:26005468

  11. Systematics of Cladophora spp. (Chlorophyta) from North Carolina, USA, based upon morphology and DNA sequence data with a description of Cladophora subtilissima sp. nov.

    PubMed

    Taylor, Robin L; Bailey, Jeffrey Craig; Freshwater, David Wilson

    2017-06-01

    Identification of Cladophora species is challenging due to conservation of gross morphology, few discrete autapomorphies, and environmental influences on morphology. Twelve species of marine Cladophora were reported from North Carolina waters. Cladophora specimens were collected from inshore and offshore marine waters for DNA sequence and morphological analyses. The nuclear-encoded rRNA internal transcribed spacer regions (ITS) were sequenced for 105 specimens and used in molecular assisted identification. The ITS1 and ITS2 region was highly variable, and sequences were sorted into ITS Sets of Alignable Sequences (SASs). Sequencing of short hyper-variable ITS1 sections from Cladophora type specimens was used to positively identify species represented by SASs when the types were made available. Secondary structures for the ITS1 locus were also predicted for each specimen and compared to predicted structures from Cladophora sequences available in GenBank. Nine ITS SASs were identified and representative specimens chosen for phylogenetic analyses of 18S and 28S rRNA gene sequences to reveal relationships with other Cladophora species. Phylogenetic analyses indicated that marine Cladophorales were polyphyletic and separated into two clades, the Cladophora clade and the "Siphonocladales" clade. Morphological analyses were performed to assess the consistency of character states within species, and complement the DNA sequence analyses. These analyses revealed intra- and interspecific character state variation, and that combined molecular and morphological analyses were required for the identification of species. One new report, Cladophora dotyana, and one new species Cladophora subtilissima sp. nov., were revealed, and increased the biodiversity of North Carolina marine Cladophora to 14 species. © 2017 Phycological Society of America.

  12. Diagnostic quality of 50 and 100 µm computed radiography compared with screen–film mammography in operative breast specimens

    PubMed Central

    Pagliari, C M; Hoang, T; Reddy, M; Wilkinson, L S; Poloniecki, J D; Given-Wilson, R M

    2012-01-01

    Objective To compare reader ratings of the clinical diagnostic quality of 50 and 100 μm computed radiography (CR) systems with screen–film mammography (SFM) in operative specimens. Methods Mammograms of 57 fresh operative breast specimens were analysed by 10 readers. Exposures were made with identical position and compression with three mammographic systems (Fuji 100CR, 50CR and SFM). Images were anonymised and readers blinded to the CR system used. A five-point comparative scoring system (−2 to +2) was used to assess seven quality criteria and overall diagnostic value. Statistical analysis was subsequently performed of reader ratings (n=16 925). Results For most quality criteria, both CR systems were rated as equivalent to or better than SFM. The CR systems were significantly better at demonstrating skin edge and background tissue (p<1×10−5). Microcalcification was best demonstrated on the CR50 system (p<1×10−5). The overall diagnostic value of both CR systems was rated as being as good as or better than SFM (p<1×10−5). Conclusion In this clinical setting, the overall diagnostic performance of both CR systems was as good as or better than SFM, with the CR50 system performing better than the CR100. PMID:22096218

  13. Evaluation of microhardness, surface roughness, and wear behavior of different types of resin composites polymerized with two different light sources.

    PubMed

    Topcu, Fulya Toksoy; Erdemir, Ugur; Sahinkesen, Gunes; Yildiz, Esra; Uslan, Ibrahim; Acikel, Cengizhan

    2010-02-01

    The microhardness, surface roughness and wear resistance of different types of resin composites, polymerized by a Quartz Tungsten Halogen (QTH) or Light Emitting Diode (LED) light curing units (LCU) were evaluated in this in vitro study. Cylindrical blocks were prepared from composites (8 mm in diameter, and 2 mm in thickness) and polymerized by a LED or a QTH LCU. Vickers hardness was measured on the top and bottom surfaces of the specimens. Surface roughness was measured with a surface profilometer on the top of the specimens. For the wear test, specimens were tested in a conventional pin-on-disc tribology machine under 15 N loads. The statistical analyses were performed by one-way analysis of variance (ANOVA) and t-tests, including the Bonferroni correction. Nanocomposite material Clearfil Majesty Posterior showed the highest hardness values in all polymerization types at the top and bottom surfaces (p < 0.05). Microhybrid Clearfil APX and hybrid Quixfil composites demonstrated the greatest surface roughness. Wear resistance of Clearfil Majesty Posterior was found to be the highest among the other tested resin composites. The results indicated that Clearfil Majesty Posterior demonstrated higher microhardness, less surface roughness, and higher wear resistance when compared with the other tested materials for both polymerization types.

  14. A proposed standard round compact specimen for plane strain fracture toughness testing

    NASA Technical Reports Server (NTRS)

    Underwood, J. H.; Newman, J. C., Jr.; Seeley, R. R.

    1980-01-01

    A round, disk-shaped specimen is proposed as a standard test specimen for addition to ASTM Test for Plane-Strain Fracture Toughness of Metallic Materials (E 399-78A). The specimen is diametrically cracked, and loaded in the same way as the existing standard compact specimen. Tests and analyses were performed to verify that the proposed round compact specimen and associated stress intensity factor K solution are appropriate for a standard plane strain fracture toughness test. The use of the round compact specimen for other fracture tests is described.

  15. Effects of different preservation methods on inter simple sequence repeat (ISSR) and random amplified polymorphic DNA (RAPD) molecular markers in botanic samples.

    PubMed

    Wang, Xiaolong; Li, Lin; Zhao, Jiaxin; Li, Fangliang; Guo, Wei; Chen, Xia

    2017-04-01

    To evaluate the effects of different preservation methods (stored in a -20°C ice chest, preserved in liquid nitrogen and dried in silica gel) on inter simple sequence repeat (ISSR) or random amplified polymorphic DNA (RAPD) analyses in various botanical specimens (including broad-leaved plants, needle-leaved plants and succulent plants) for different times (three weeks and three years), we used a statistical analysis based on the number of bands, genetic index and cluster analysis. The results demonstrate that methods used to preserve samples can provide sufficient amounts of genomic DNA for ISSR and RAPD analyses; however, the effect of different preservation methods on these analyses vary significantly, and the preservation time has little effect on these analyses. Our results provide a reference for researchers to select the most suitable preservation method depending on their study subject for the analysis of molecular markers based on genomic DNA. Copyright © 2017 Académie des sciences. Published by Elsevier Masson SAS. All rights reserved.

  16. Training in metabolomics research. II. Processing and statistical analysis of metabolomics data, metabolite identification, pathway analysis, applications of metabolomics and its future

    PubMed Central

    Barnes, Stephen; Benton, H. Paul; Casazza, Krista; Cooper, Sara; Cui, Xiangqin; Du, Xiuxia; Engler, Jeffrey; Kabarowski, Janusz H.; Li, Shuzhao; Pathmasiri, Wimal; Prasain, Jeevan K.; Renfrow, Matthew B.; Tiwari, Hemant K.

    2017-01-01

    Metabolomics, a systems biology discipline representing analysis of known and unknown pathways of metabolism, has grown tremendously over the past 20 years. Because of its comprehensive nature, metabolomics requires careful consideration of the question(s) being asked, the scale needed to answer the question(s), collection and storage of the sample specimens, methods for extraction of the metabolites from biological matrices, the analytical method(s) to be employed and the quality control of the analyses, how collected data are correlated, the statistical methods to determine metabolites undergoing significant change, putative identification of metabolites, and the use of stable isotopes to aid in verifying metabolite identity and establishing pathway connections and fluxes. This second part of a comprehensive description of the methods of metabolomics focuses on data analysis, emerging methods in metabolomics and the future of this discipline. PMID:28239968

  17. A Comparative Study on the Role of Xpert MTB/RIF in Testing Different Types of Spinal Tuberculosis Tissue Specimens.

    PubMed

    Tang, Liang; Feng, Shiqing; Gao, Ruixiao; Han, Chenfu; Sun, Xiaochen; Bao, Yucheng; Zhang, Wenlong

    2017-12-01

    The aim of the present study was to compare the efficacy of the commercial Xpert Mycobacterium tuberculosis/rifampin (MTB/RIF) test for evaluating different types of spinal tuberculosis (TB) tissue specimens. Pus, granulation tissue, and caseous necrotic tissue specimens from 223 patients who were diagnosed with spinal TB and who underwent curettage were collected for bacterial culture and the Xpert MTB/RIF assay to calculate the positive rate. Bacterial culture and phenotypic drug sensitivity testing (pDST) were adopted as the gold standards to calculate the sensitivity and specificity of the Xpert bacterial detection and drug resistance (DR) test. The positive rate (68.61% ± 7.35%) from the Xpert MTB/RIF assays of spinal TB patients' tissue specimens was higher compared with bacterial culture (44.39% ± 6.51%, Z = 5.1642, p < 0.01), and the positive rates from Xpert MTB/RIF assays on the three types of specimens were all higher than those of bacterial culture, with statistically significant results for pus and granulation tissue specimens. The positive rates for pus using the two bacteriological tests were higher than those for granulation tissue but were not statistically significant. However, the positive rates obtained from granulation tissue were statistically significantly higher than those obtained from caseous necrotic tissue. With bacterial culture and pDST as the gold standards, the sensitivity of Xpert MTB/RIF assays for MTB was 96.97%, while the sensitivity and specificity of the DR test also remained relatively high. For efficient and accurate diagnosis of spinal TB and DR and timely provision of effective treatment, multiple specimens, especially the pus of spinal TB patients, should be collected for Xpert MTB/RIF assays.

  18. Cytokeratin 19 Expression Patterns of Dentigerous Cysts and Odontogenic Keratocysts

    PubMed Central

    Kamath, KP; Vidya, M

    2015-01-01

    Background: Although numerous investigators have studied the pattern of keratin expression in different odontogenic cysts, the results have been variable. Aim: The present study was conducted to determine the pattern of expression of cytokeratin 19 (CK 19) in the epithelial lining of odontogenic keratocysts and dentigerous cysts. Materials and Methods: The epithelial layers showing expression of the epithelial marker CK 19 was determined by immunohistochemical methods in 15 tissue specimens each of histopathologically confirmed cases of dentigerous cysts and odontogenic keratocysts. Statistical analysis was done to compare the CK 19 expression between dentigerous cyst and odontogenic keratocyst using the Chi-square test. P < 0.05 was considered to be statistically significant. Results: All specimens of dentigerous cysts were positive for CK 19 with 20% (3/15) of the specimens showing expression only in a single layer of the epithelium, 40% (6/15) of the specimens showing expression in more than one layer but not the entire thickness of the epithelium, and the remaining 40% (6/15) showing expression throughout the entire thickness of the epithelium. In the case of odontogenic keratocysts, 40% (6/15) of the specimens were negative for CK 19, 40% (6/15) of the specimens showed expression only in a single layer of the epithelium, and 20% (3/15) of the specimens showed expression in more than one layer, but not the entire thickness of the epithelium. The observed differences in CK 19 expression by the two lesions were statistically significant (P < 0.01). Conclusion: The differences in CK 19 expression by these cysts may be utilized as a diagnostic tool in differentiating between these two lesions. PMID:25861531

  19. Corrosion resistance assessment of Co-Cr alloy frameworks fabricated by CAD/CAM milling, laser sintering, and casting methods.

    PubMed

    Tuna, Süleyman Hakan; Özçiçek Pekmez, Nuran; Kürkçüoğlu, Işin

    2015-11-01

    The effects of fabrication methods on the corrosion resistance of frameworks produced with Co-Cr alloys are not clear. The purpose of this in vitro study was to evaluate the electrochemical corrosion resistance of Co-Cr alloy specimens that were fabricated by conventional casting, milling, and laser sintering. The specimens fabricated with 3 different methods were investigated by potentiodynamic tests and electrochemical impedance spectroscopy in an artificial saliva. Ions released into the artificial saliva were estimated with inductively coupled plasma-mass spectrometry, and the results were statistically analyzed. The specimen surfaces were investigated with scanning electron microscopy before and after the tests. In terms of corrosion current and Rct properties, statistically significant differences were found both among the means of the methods and among the means of the material groups (P<.05). With regard to ions released, a statistically significant difference was found among the material groups (P<.05); however, no difference was found among the methods. Scanning electron microscopic imaging revealed that the specimens produced by conventional casting were affected to a greater extent by etching and electrochemical corrosion than those produced by milling and laser sintering. The corrosion resistance of a Co-Cr alloy specimens fabricated by milling or laser sintering was greater than that of the conventionally cast alloy specimens. The Co-Cr specimens produced by the same method also differed from one another in terms of corrosion resistance. These differences may be related to the variations in the alloy compositions. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. Cheek tooth morphology and ancient mitochondrial DNA of late Pleistocene horses from the western interior of North America: Implications for the taxonomy of North American Late Pleistocene Equus

    PubMed Central

    Rodrigues, Antonia T.; Theodor, Jessica M.; Kooyman, Brian P.; Yang, Dongya Y.; Speller, Camilla F.

    2017-01-01

    Horses were a dominant component of North American Pleistocene land mammal communities and their remains are well represented in the fossil record. Despite the abundant material available for study, there is still considerable disagreement over the number of species of Equus that inhabited the different regions of the continent and on their taxonomic nomenclature. In this study, we investigated cheek tooth morphology and ancient mtDNA of late Pleistocene Equus specimens from the Western Interior of North America, with the objective of clarifying the species that lived in this region prior to the end-Pleistocene extinction. Based on the morphological and molecular data analyzed, a caballine (Equus ferus) and a non-caballine (E. conversidens) species were identified from different localities across most of the Western Interior. A second non-caballine species (E. cedralensis) was recognized from southern localities based exclusively on the morphological analyses of the cheek teeth. Notably the separation into caballine and non-caballine species was observed in the Bayesian phylogenetic analysis of ancient mtDNA as well as in the geometric morphometric analyses of the upper and lower premolars. Teeth morphologically identified as E. conversidens that yielded ancient mtDNA fall within the New World stilt-legged clade recognized in previous studies and this is the name we apply to this group. Geographic variation in morphology in the caballine species is indicated by statistically different occlusal enamel patterns in the specimens from Bluefish Caves, Yukon Territory, relative to the specimens from the other geographic regions. Whether this represents ecomorphological variation and/or a certain degree of geographic and genetic isolation of these Arctic populations requires further study. PMID:28817644

  1. Cheek tooth morphology and ancient mitochondrial DNA of late Pleistocene horses from the western interior of North America: Implications for the taxonomy of North American Late Pleistocene Equus.

    PubMed

    Barrón-Ortiz, Christina I; Rodrigues, Antonia T; Theodor, Jessica M; Kooyman, Brian P; Yang, Dongya Y; Speller, Camilla F

    2017-01-01

    Horses were a dominant component of North American Pleistocene land mammal communities and their remains are well represented in the fossil record. Despite the abundant material available for study, there is still considerable disagreement over the number of species of Equus that inhabited the different regions of the continent and on their taxonomic nomenclature. In this study, we investigated cheek tooth morphology and ancient mtDNA of late Pleistocene Equus specimens from the Western Interior of North America, with the objective of clarifying the species that lived in this region prior to the end-Pleistocene extinction. Based on the morphological and molecular data analyzed, a caballine (Equus ferus) and a non-caballine (E. conversidens) species were identified from different localities across most of the Western Interior. A second non-caballine species (E. cedralensis) was recognized from southern localities based exclusively on the morphological analyses of the cheek teeth. Notably the separation into caballine and non-caballine species was observed in the Bayesian phylogenetic analysis of ancient mtDNA as well as in the geometric morphometric analyses of the upper and lower premolars. Teeth morphologically identified as E. conversidens that yielded ancient mtDNA fall within the New World stilt-legged clade recognized in previous studies and this is the name we apply to this group. Geographic variation in morphology in the caballine species is indicated by statistically different occlusal enamel patterns in the specimens from Bluefish Caves, Yukon Territory, relative to the specimens from the other geographic regions. Whether this represents ecomorphological variation and/or a certain degree of geographic and genetic isolation of these Arctic populations requires further study.

  2. Rapid differentiation of cocci/mixed bacteria from rods in voided urine culture of women with uncomplicated urinary tract infections.

    PubMed

    Yang, Chun-Chun; Yang, Stephen Shei-Dei; Hung, Hui-Ching; Chiang, I-Ni; Peng, Chiung-Hui; Chang, Shang-Jen

    2017-09-01

    To evaluate the ability of laser flow cytometry to predict cocci/mixed growth in the pre-analytical phase of urine specimens. We retrospectively reviewed urine samples from women with uncomplicated urinary tract infections from urologic clinics for study. Urine analyses were performed with laser flow cytometry (UF1000i, Sysmex, Kobe, Japan) and then diagrams were generated (forward scatter vs. fluorescent light scatter). Each specimen (bacteria count >357 BACT/μL) was classified as either cocci bacteria or rods/mixed growth according to the diagrams. Standard urine cultures were performed, and the agreement between cultures and the UF1000i interpretations was analyzed with kappa statistics. Finally, 491 specimens met the criteria for analysis. Among the 376 specimens with single bacteria growth, there were 26 gram-positive cocci (13 Streptococci spp., 7 Staphylococci spp., 6 Enterococci spp.), 1 gram-positive rods (Corynebacterium spp.), and 349 gram-negative rods (273 Escherichia coli, 33 Klebsiella spp., 29 Proteus spp., 6 Citrobacter spp., 4 Enterobacter spp., 3 Pseudomonas spp., and 1 Providencia spp.). There were 115 specimens with two bacteria species or more that were regarded as mixed growth. Agreement of rods or cocci/mixed growth between the laser flow cytometry and urine cultures yielded a kappa value of 0.58. The positive and negative predictive rate of the UF1000i for cocci/mixed growth in voided urine culture was 81.8% and 84.7%, respectively. Through laser flow cytometry, we can predict growth of cocci/mixed growth in the pre-analytical phase of urine culture, thus avoiding unnecessary urine culture and waiting time. © 2016 Wiley Periodicals, Inc.

  3. Optimization of routine KRAS mutation PCR-based testing procedure for rational individualized first-line-targeted therapy selection in metastatic colorectal cancer.

    PubMed

    Chretien, Anne-Sophie; Harlé, Alexandre; Meyer-Lefebvre, Magali; Rouyer, Marie; Husson, Marie; Ramacci, Carole; Harter, Valentin; Genin, Pascal; Leroux, Agnès; Merlin, Jean-Louis

    2013-02-01

    KRAS mutation detection represents a crucial issue in metastatic colorectal cancer (mCRC). The optimization of KRAS mutation detection delay enabling rational prescription of first-line treatment in mCRC including anti-EGFR-targeted therapy requires robust and rapid molecular biology techniques. Routine analysis of mutations in codons 12 and 13 on 674 paraffin-embedded tissue specimens of mCRC has been performed for KRAS mutations detection using three molecular biology techniques, that is, high-resolution melting (HRM), polymerase chain reaction restriction fragment length polymorphism (PCR-RFLP), and allelic discrimination PCR (TaqMan PCR). Discordant cases were assessed with COBAS 4800 KRAS CE-IVD assay. Among the 674 tumor specimens, 1.5% (10/674) had excessive DNA degradation and could not be analyzed. KRAS mutations were detected in 38.0% (256/674) of the analysable specimens (82.4% in codon 12 and 17.6% in codon 13). Among 613 specimens in whom all three techniques were used, 12 (2.0%) cases of discordance between the three techniques were observed. 83.3% (10/12) of the discordances were due to PCR-RFLP as confirmed by COBAS 4800 retrospective analysis. The three techniques were statistically comparable (κ > 0.9; P < 0.001). From these results, optimization of the routine procedure consisted of proceeding to systematic KRAS detection using HRM and TaqMan and PCR-RFLP in case of discordance and allowed significant decrease in delays. The results showed an excellent correlation between the three techniques. Using HRM and TaqMan warrants high-quality and rapid-routine KRAS mutation detection in paraffin-embedded tumor specimens. The new procedure allowed a significant decrease in delays for reporting results, enabling rational prescription of first-line-targeted therapy in mCRC.

  4. Mineral content changes in bone associated with damage induced by the electron beam.

    PubMed

    Bloebaum, Roy D; Holmes, Jennifer L; Skedros, John G

    2005-01-01

    Energy-dispersive x-ray (EDX) spectroscopy and backscattered electron (BSE) imaging are finding increased use for determining mineral content in microscopic regions of bone. Electron beam bombardment, however, can damage the tissue, leading to erroneous interpretations of mineral content. We performed elemental (EDX) and mineral content (BSE) analyses on bone tissue in order to quantify observable deleterious effects in the context of (1) prolonged scanning time, (2) scan versus point (spot) mode, (3) low versus high magnification, and (4) embedding in poly-methylmethacrylate (PMMA). Undemineralized cortical bone specimens from adult human femora were examined in three groups: 200x embedded, 200x unembedded, and 1000x embedded. Coupled BSE/EDX analyses were conducted five consecutive times, with no location analyzed more than five times. Variation in the relative proportions of calcium (Ca), phosphorous (P), and carbon (C) were measured using EDX spectroscopy, and mineral content variations were inferred from changes in mean gray levels ("atomic number contrast") in BSE images captured at 20 keV. In point mode at 200x, the embedded specimens exhibited a significant increase in Ca by the second measurement (7.2%, p < 0.05); in scan mode, a small and statistically nonsignificant increase (1.0%) was seen by the second measurement. Changes in P were similar, although the increases were less. The apparent increases in Ca and P likely result from decreases in C: -3.2% (p < 0.05) in point mode and -0.3% in scan mode by the second measurement. Analysis of unembedded specimens showed similar results. In contrast to embedded specimens at 200x, 1000x data showed significantly larger variations in the proportions of Ca, P, and C by the second or third measurement in scan and point mode. At both magnifications, BSE image gray level values increased (suggesting increased mineral content) by the second measurement, with increases up to 23% in point mode. These results show that mineral content measurements can be reliable when using coupled BSE/EDX analyses in PMMA-embedded bone if lower magnifications are used in scan mode and if prolonged exposure to the electron beam is avoided. When point mode is used to analyze minute regions, adjustments in accelerating voltages and probe current may be required to minimize damage.

  5. Dried blood spot specimen quality and validation of a new pre-analytical processing method for qualitative HIV-1 PCR, KwaZulu-Natal, South Africa

    PubMed Central

    Parboosing, Raveen; Siyaca, Ntombizandile; Moodley, Pravikrishnen

    2016-01-01

    Background Poor quality dried blood spot (DBS) specimens are usually rejected by virology laboratories, affecting early infant diagnosis of HIV. The practice of combining two incompletely-filled DBS in one specimen preparation tube during pre-analytical specimen processing (i.e., the two-spot method) has been implemented to reduce the number of specimens being rejected for insufficient volume. Objectives This study analysed laboratory data to describe the quality of DBS specimens and the use of the two-spot method over a one-year period, then validated the two-spot method against the standard (one-spot) method. Methods Data on HIV-1 PCR test requests submitted in 2014 to the Department of Virology at Inkosi Albert Luthuli Central Hospital in KwaZulu-Natal province, South Africa were analysed to describe reasons for specimen rejection, as well as results of the two-spot method. The accuracy, lower limit of detection and precision of the two-spot method were assessed. Results Of the 88 481 specimens received, 3.7% were rejected for pre-analytical problems. Of those, 48.9% were rejected as a result of insufficient specimen volume. Two health facilities had significantly more specimen rejections than other facilities. The two-spot method prevented 10 504 specimen rejections. The Pearson correlation coefficient comparing the standard to the two-spot method was 0.997. Conclusions The two-spot method was comparable with the standard method of pre-analytical specimen processing. Two health facilities were identified for targeted retraining on specimen quality. The two-spot method of DBS specimen processing can be used as an adjunct to retraining, to reduce the number of specimens rejected and improve linkage to care. PMID:28879108

  6. Dried blood spot specimen quality and validation of a new pre-analytical processing method for qualitative HIV-1 PCR, KwaZulu-Natal, South Africa.

    PubMed

    Govender, Kerusha; Parboosing, Raveen; Siyaca, Ntombizandile; Moodley, Pravikrishnen

    2016-01-01

    Poor quality dried blood spot (DBS) specimens are usually rejected by virology laboratories, affecting early infant diagnosis of HIV. The practice of combining two incompletely-filled DBS in one specimen preparation tube during pre-analytical specimen processing (i.e., the two-spot method) has been implemented to reduce the number of specimens being rejected for insufficient volume. This study analysed laboratory data to describe the quality of DBS specimens and the use of the two-spot method over a one-year period, then validated the two-spot method against the standard (one-spot) method. Data on HIV-1 PCR test requests submitted in 2014 to the Department of Virology at Inkosi Albert Luthuli Central Hospital in KwaZulu-Natal province, South Africa were analysed to describe reasons for specimen rejection, as well as results of the two-spot method. The accuracy, lower limit of detection and precision of the two-spot method were assessed. Of the 88 481 specimens received, 3.7% were rejected for pre-analytical problems. Of those, 48.9% were rejected as a result of insufficient specimen volume. Two health facilities had significantly more specimen rejections than other facilities. The two-spot method prevented 10 504 specimen rejections. The Pearson correlation coefficient comparing the standard to the two-spot method was 0.997. The two-spot method was comparable with the standard method of pre-analytical specimen processing. Two health facilities were identified for targeted retraining on specimen quality. The two-spot method of DBS specimen processing can be used as an adjunct to retraining, to reduce the number of specimens rejected and improve linkage to care.

  7. Effects of Different Surface Treatment Methods and MDP Monomer on Resin Cementation of Zirconia Ceramics an In Vitro Study

    PubMed Central

    Tanış, Merve Çakırbay; Akçaboy, Cihan

    2015-01-01

    Introduction: Resin cements are generally preferred for cementation of zirconia ceramics. Resin bonding of zirconia ceramics cannot be done with the same methods of traditional ceramics because zirconia is a silica-free material. In recent years, many methods have been reported in the literature to provide the resin bonding of zirconia ceramics. The purpose of this in vitro study is to evaluate effects of different surface treatments and 10-metacryloxydecyl dihydrogen phosphate (MDP) monomer on shear bond strength between zirconia and resin cement. Methods: 120 zirconia specimens were treated as follows: Group I: sandblasting, group II: sandblasting + tribochemical silica coating + silane, group III: sandblasting + Nd:YAG (neodymium: yttrium-aluminum-garnet) laser. One specimen from each group was evaluated under scanning electron microscope (SEM). Specimens in each group were bonded either with conventional resin cement Variolink II or with a MDP containing resin cement Panavia F2.0. Subgroups of bonded specimens were stored in distilled water (37°C) for 24 hours or 14 days. Following water storage shear bond strength test was performed at a crosshead speed of 1 mm/min in a universal test machine. Then statistical analyses were performed. Results: Highest shear bond strength values were observed in group II. No significant difference between group I and III was found when Panavia F2.0 resin cement was used. When Variolink II resin cement was used group III showed significantly higher bond strength than group I. In group I, Panavia F2.0 resin cement showed statistically higher shear bond strength than Variolink II resin cement. In group II no significant difference was found between resin cements. No significant difference was found between specimens stored in 37°C distilled water for 24 hours and 14 days. In group I surface irregularities with sharp edges and grooves were observed. In group II less roughened surface was observed with silica particles. In group III surface microcracks connecting each other were observed. Conclusion: Tribochemical silica coating is an effective method for achieving an acceptable bond between zirconia and resin cement. Use of a MDP monomer containing resin cement increases the bond strength of sandblasted zirconia. PMID:26705464

  8. Effect of Surface Treatment, Silane, and Universal Adhesive on Microshear Bond Strength of Nanofilled Composite Repairs.

    PubMed

    Fornazari, I A; Wille, I; Meda, E M; Brum, R T; Souza, E M

     The aim of this study was to evaluate the effect of surface treatment and universal adhesive on the microshear bond strength of nanoparticle composite repairs.  One hundred and forty-four specimens were built with a nanofilled composite (Filtek Supreme Ultra, 3M ESPE). The surfaces of all the specimens were polished with SiC paper and stored in distilled water at 37°C for 14 days. Half of the specimens were then air abraded with Al 2 O 3 particles and cleaned with phosphoric acid. Polished specimens (P) and polished and air-abraded specimens (A), respectively, were randomly divided into two sets of six groups (n=12) according to the following treatments: hydrophobic adhesive only (PH and AH, respectively), silane and hydrophobic adhesive (PCH, ACH), methacryloyloxydecyl dihydrogen phosphate (MDP)-containing silane and hydrophobic adhesive (PMH, AMH), universal adhesive only (PU, AU), silane and universal adhesive (PCU, ACU), and MDP-containing silane and universal adhesive (PMU, AMU). A cylinder with the same composite resin (1.1-mm diameter) was bonded to the treated surfaces to simulate the repair. After 48 hours, the specimens were subjected to microshear testing in a universal testing machine. The failure area was analyzed under an optical microscope at 50× magnification to identify the failure type, and the data were analyzed by three-way analysis of variance and the Games-Howell test (α=0.05).  The variables "surface treatment" and "adhesive" showed statistically significant differences for p<0.05. The highest mean shear bond strength was found in the ACU group but was not statistically different from the means for the other air-abraded groups except AH. All the polished groups except PU showed statistically significant differences compared with the air-abraded groups. The PU group had the highest mean among the polished groups. Cohesive failure was the most frequent failure mode in the air-abraded specimens, while mixed failure was the most common mode in the polished specimens.  While air abrasion with Al 2 O 3 particles increased the repair bond strength of the nanoparticle composite, the use of MDP-containing silane did not lead to a statistically significant increase in bond strength. Silane-containing universal adhesive on its own was as effective as any combination of silane and adhesive, particularly when applied on air-abraded surfaces.

  9. Operative outcomes of conventional specimen radiography versus in-operating room specimen radiography in radioactive seed-localized segmental mastectomies.

    PubMed

    Rhee, Daniel; Pockaj, Barbara; Wasif, Nabil; Stucky, Chee-Chee; Pizzitola, Victor; Giurescu, Marina; Patel, Bhavika; McCarthy, Janice; Gray, Richard

    2018-01-01

    In-operating room specimen radiography (ORSR) has not been studied among women undergoing radioactive seed localization (RSL) for breast cancer surgery and had the potential to decrease operative time and perhaps improve intraoperative margin management. One hundred consecutive RSL segmental mastectomies among 98 patients using ORSR were compared to 100 consecutive segmental mastectomies among 98 patients utilizing conventional radiography (CSR) prior to the initiation of ORSR from December 2013 to January 2015 after radioactive seed localization. Final pathologic margins were considered to be 10 mm for all cases of no residual disease after biopsy or neoadjuvant therapy, but such patients were excluded from analyses involving tumor size. All patients' specimens were subjected to intraoperative pathologic consultation in addition to ORSR or CSR. The median age of the cohort was 65 years (range 36-97), and the median tumor size was 1 cm. There were no differences between the ORSR and CSR groups in age, tumor size, percentage of cases with only DCIS, and percentage of cases with microcalcifications. The ORSR group had a statistically significant lower BMI. Mean operative time from cut-to-close was not significantly different (ORSR 77 min, SD 24.8 vs CSR 76 min, SD 24.8, p = 0.75). There was no statistical difference in mean closest final pathologic margin (4.99 mm, SD 3.3 vs 4.88 mm, SD 3.5, p = 0.9). The percentage undergoing intraoperative margin re-excision (ORSR 40%, CR 47%, p = 0.31) and the mean total number of margins excised intraoperatively (ORSR 0.9, CR 1.0 p = 0.65) were similar. The rate of any margin <2 mm was 14% vs 12% for ORSR and CR, respectively (p = 0.64). The mean specimen volume for ORSR was 76cm3 (SD 101.8) vs 90cm3 (SD 61.2) for CSR; this difference was not statistically significant (p = 0.25). The mean ratio of segmental mastectomy volume to maximum tumor diameter was less for ORSR (82.7cm2 vs 139.4cm2, p = 0.014). ORSR for RSL breast surgery, in the setting of routine intraoperative pathology consultation, does not significantly impact operative time, the rate or number of additional intraoperative margins excised, the number of reoperations for margins, or the width of final pathological margins. ORSR was associated with a decrease in the volume of segmental mastectomies relative to the tumor diameter. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. An exploration of the accuracy of an invasive method for measuring the volume of specimens of Amoeba proteus.

    PubMed

    Whalen, T A; Demarco, A J

    1999-10-01

    A method is described for measuring the volume of individual specimens of Amoeba proteus which utilizes an easily constructed compressor to flatten the specimen to a known thickness. The microscopic image of the flattened specimen is captured on tape, digitized and analysed with the NIH Image software. The results from one specimen are given to illustrate the sources and magnitude of errors affecting these volume measurements.

  11. Dose fractionation theorem in 3-D reconstruction (tomography)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glaeser, R.M.

    It is commonly assumed that the large number of projections for single-axis tomography precludes its application to most beam-labile specimens. However, Hegerl and Hoppe have pointed out that the total dose required to achieve statistical significance for each voxel of a computed 3-D reconstruction is the same as that required to obtain a single 2-D image of that isolated voxel, at the same level of statistical significance. Thus a statistically significant 3-D image can be computed from statistically insignificant projections, as along as the total dosage that is distributed among these projections is high enough that it would have resultedmore » in a statistically significant projection, if applied to only one image. We have tested this critical theorem by simulating the tomographic reconstruction of a realistic 3-D model created from an electron micrograph. The simulations verify the basic conclusions of high absorption, signal-dependent noise, varying specimen contrast and missing angular range. Furthermore, the simulations demonstrate that individual projections in the series of fractionated-dose images can be aligned by cross-correlation because they contain significant information derived from the summation of features from different depths in the structure. This latter information is generally not useful for structural interpretation prior to 3-D reconstruction, owing to the complexity of most specimens investigated by single-axis tomography. These results, in combination with dose estimates for imaging single voxels and measurements of radiation damage in the electron microscope, demonstrate that it is feasible to use single-axis tomography with soft X-ray microscopy of frozen-hydrated specimens.« less

  12. The mammalian bony labyrinth reconsidered, introducing a comprehensive geometric morphometric approach

    PubMed Central

    Gunz, Philipp; Ramsier, Marissa; Kuhrig, Melanie; Hublin, Jean-Jacques; Spoor, Fred

    2012-01-01

    The bony labyrinth in the temporal bone houses the sensory systems of balance and hearing. While the overall structure of the semicircular canals and cochlea is similar across therian mammals, their detailed morphology varies even among closely related groups. As such, the shape of the labyrinth carries valuable functional and phylogenetic information. Here we introduce a new, semilandmark-based three-dimensional geometric morphometric approach to shape analysis of the labyrinth, as a major improvement upon previous metric studies based on linear measurements and angles. We first provide a detailed, step-by-step description of the measurement protocol. Subsequently, we test our approach using a geographically diverse sample of 50 recent modern humans and 30 chimpanzee specimens belonging to Pan troglodytes troglodytes and P. t. verus. Our measurement protocol can be applied to CT scans of different spatial resolutions because it primarily quantifies the midline skeleton of the bony labyrinth. Accurately locating the lumen centre of the semicircular canals and the cochlea is not affected by the partial volume and thresholding effects that can make the comparison of the outer border problematic. After virtually extracting the bony labyrinth from CT scans of the temporal bone, we computed its midline skeleton by thinning the encased volume. On the resulting medial axes of the semicircular canals and cochlea we placed a sequence of semilandmarks. After Procrustes superimposition, the shape coordinates were analysed using multivariate statistics. We found statistically significant shape differences between humans and chimpanzees which corroborate previous analyses of the labyrinth based on traditional measurements. As the geometric relationship among the semilandmark coordinates was preserved throughout the analysis, we were able to quantify and visualize even small-scale shape differences. Notably, our approach made it possible to detect and visualize subtle, yet statistically significant (P = 0.009), differences between two chimpanzee subspecies in the shape of their semicircular canals. The ability to discriminate labyrinth shape at the subspecies level demonstrates that the approach presented here has great potential in future taxonomic studies of fossil specimens. PMID:22404255

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cuffey, R.J.; Pachut, J.F.

    The Holocene reef-building coral Favia pallida was sampled at 4.5 m depth increments (to 40 m) from two reefs on Enewetak Atoll to examine intraspecific environmental effects. An exposed outer reef was massive and wall-like, whereas a sheltered lagoonal reef grew as a slender pinnacle. Corallite diameter and growth rate, two attributes retrievable in fossil corals, were measured with data partitioned into shallow (<20 m), intermediate (20 to 29 m), and deep-water (>29 m) subsets. Highly significant differences between depth zone populations were found for both corallite diameters and growth rates in analyses of individual and combined reef data sets.more » Canonical variates analyses (CVA) separated populations from depth zones along single, highly significant, functions. Centroids and 95% confidence intervals, calculated from CVA scores of colonies in each population, are widely separated for the lagoon reef and combined data sets. Conversely, populations from shallow and intermediate depths on the outer reef display overlapping confidence bars indicative of more gradational morphologic changes. When CV's were used to classify specimens to groups, misassignments of intermediate depth specimens to shallow or deep-water populations underscored the gradational nature of the environment. Completely intergrading populations of Favia pallida collected from different depths can be morphologically separated into statistically distinct groupings. A stratigraphic succession of such morphotypes might be interpreted as abruptly appearing separate species if sampling were not as uniform, systematic, and detailed as was possible on modern reefs. Analyses of evolutionary patterns must carefully assess potential effects of clinal variation if past evolutionary patterns are to be interpreted correctly.« less

  14. Elevated expression of Thoc1 is associated with aggressive phenotype and poor prognosis in colorectal cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Chenchen; Yue, Ben; Yuan, Chenwei

    The THO complex 1 (Thoc1) is a nuclear matrix protein playing vital roles in transcription elongation and mRNA export. Recently, aberrant expression of Thoc1 has been reported in an increasing array of tumor types. However, the clinical significance of Thoc1 expression in colorectal cancer (CRC) is still unknown. The present study aimed to characterize the expression of Thoc1 in human CRC and evaluate its clinical significance. Quantitative real-time polymerase chain reaction (qRT-PCR) and Western blotting analyses showed that the mRNA and protein expression of Thoc1 in CRC specimens was significantly higher than that in adjacent normal colon mucosae. Immunohistochemistry (IHC)more » was conducted to characterize the expression pattern of Thoc1 in 185 archived paraffin-embedded CRC specimens. Statistical analyses revealed that high levels of Thoc1 expression were associated with the clinical stages and tumor differentiation. CRC patients with high levels of Thoc1 expression had poorer overall-survival and disease-free survival, whereas those with lower levels of Thoc1 expression survived longer. Furthermore, multivariate Cox regression analyses demonstrated that Thoc1 expression remained an independent prognostic factor for increased disease recurrence and decreased survival. Our results suggest for the first time that Thoc1 is involved in the development and progression of CRC, and elevated expression of Thoc1 is associated with aggressive phenotype and poor prognosis in CRC. These findings may prove to be clinically useful for developing a new therapeutic target of CRC treatment.« less

  15. [Non-small cell lung cancer. Subtyping and predictive molecular marker investigations in cytology].

    PubMed

    Savic, S; Bihl, M P; Bubendorf, L

    2012-07-01

    The diagnosis and treatment of non-small cell lung cancer (NSCLC) have been revolutionized over the last few years. Requirements for cytopathologists in lung cancer diagnosis have therefore changed. The general diagnostic category of NSLC is no longer sufficient. In addition cytological specimens need to be evaluated for adequacy regarding predictive marker analyses. Accurate NSCLC subtyping with a distinction of adenocarcinoma from squamous cell carcinoma is crucial for treatment decisions as the subtype will decide on the chemotherapy regimen and the choice of predictive marker analyses for targeted treatment. In the majority of cases, the subtype can be diagnosed by morphology alone. Cytology is equally well suited as biopsy specimens for the assessment of molecular predictive markers. The best results are achieved when both cytology and biopsy specimens are compared to choose the most appropriate specimen for morphological subtyping and molecular testing. In this paper, we discuss special issues of NSCLC subtyping and currently recommended predictive molecular marker analyses.

  16. Large-displacement structural durability analyses of simple bend specimen emulating rocket nozzle liners

    NASA Technical Reports Server (NTRS)

    Arya, Vinod K.; Halford, Gary R.

    1994-01-01

    Large-displacement elastic and elastic-plastic, finite-element stress-strain analyses of an oxygen-tree high-conductivity (OFHC) copper plate specimen were performed using an updated Lagrangian formulation. The plate specimen is intended for low-cost experiments that emulate the most important thermomechanical loading and failure modes of a more complex rocket nozzle. The plate, which is loaded in bending at 593 C, contains a centrally located and internally pressurized channel. The cyclic crack initiation lives were estimated using the results from the analyses and isothermal strain-controlled low-cycle fatigue data for OFHC copper. A comparison of the predicted and experimental cyclic lives showed that an elastic analysis predicts a longer cyclic life than that observed in experiments by a factor greater than 4. The results from elastic-plastic analysis for the plate bend specimen, however, predicted a cyclic life in close agreement with experiment, thus justifying the need for the more rigorous stress-strain analysis.

  17. Statistical analysis on experimental calibration data for flowmeters in pressure pipes

    NASA Astrophysics Data System (ADS)

    Lazzarin, Alessandro; Orsi, Enrico; Sanfilippo, Umberto

    2017-08-01

    This paper shows a statistical analysis on experimental calibration data for flowmeters (i.e.: electromagnetic, ultrasonic, turbine flowmeters) in pressure pipes. The experimental calibration data set consists of the whole archive of the calibration tests carried out on 246 flowmeters from January 2001 to October 2015 at Settore Portate of Laboratorio di Idraulica “G. Fantoli” of Politecnico di Milano, that is accredited as LAT 104 for a flow range between 3 l/s and 80 l/s, with a certified Calibration and Measurement Capability (CMC) - formerly known as Best Measurement Capability (BMC) - equal to 0.2%. The data set is split into three subsets, respectively consisting in: 94 electromagnetic, 83 ultrasonic and 69 turbine flowmeters; each subset is analysed separately from the others, but then a final comparison is carried out. In particular, the main focus of the statistical analysis is the correction C, that is the difference between the flow rate Q measured by the calibration facility (through the accredited procedures and the certified reference specimen) minus the flow rate QM contemporarily recorded by the flowmeter under calibration, expressed as a percentage of the same QM .

  18. Color stability of shade guides after autoclave sterilization.

    PubMed

    Schmeling, Max; Sartori, Neimar; Monteiro, Sylvio; Baratieri, Luiz

    2014-01-01

    This study evaluated the influence of 120 autoclave sterilization cycles on the color stability of two commercial shade guides (Vita Classical and Vita System 3D-Master). The specimens were evaluated by spectrophotometer before and after the sterilization cycles. The color was described using the three-dimensional CIELab system. The statistical analysis was performed in three chromaticity coordinates, before and after sterilization cycles, using the paired samples t test. All specimens became darker after autoclave sterilization cycles. However, specimens of Vita Classical became redder, while those of the Vita System 3D-Master became more yellow. Repeated cycles of autoclave sterilization caused statistically significant changes in the color coordinates of the two shade guides. However, these differences are considered clinically acceptable.

  19. Female genital tract bacterial coisolates with Candida albicans in patients without clinical vaginitis.

    PubMed Central

    Monif, G R; Carson, H J

    1998-01-01

    OBJECTIVE: In vitro, Candida albicans has demonstrated the ability to inhibit replication of selected bacteria. Little information exists on the impact of C. albicans on the vaginal bacterial flora in vivo. The purpose of this study is to identify the coexisting bacterial flora when C. albicans is isolated from vaginal cultures submitted to a hospital-based testing facility for reasons other than vulvovaginitis. METHODOLOGY: All specimens (240) received from ambulatory care clinics over a six-month period were cultured for aerobic and anaerobic bacteria and Candida species. Those specimens submitted for cervicitis, vaginitis, or vaginal discharge and those from which yeasts other than C. albicans were isolated were eliminated. To control for sample biases, a subgroup composed of all pregnant women for whom cultures were done as screening procedures was similarly studied. Chi-square analyses, comparing the prevalence of individual bacteria isolated with and without the presence of C. albicans, were done for all study populations using SPSS for Windows software (1994). RESULTS: Two hundred and forty consecutive specimens were bacteriologically analyzed. Of the 220 vaginal samples used in the study, C. albicans was isolated in 44 instances (20%). Neither the presence of the lactobacilli nor the presence of Gardnerella vaginalis markedly influenced the isolation rate of C. albicans. The group B streptococci had a greater probability of coisolation when C. albicans was present (27.3% verses 16%), but this was not statistically significant (P < 0.8). Dissociation between the presence of C. albicans and the coisolation of Peptostreptococcus species and anaerobic gram-positive cocci and/or bacilli was noted (P < 0.0819), while the incidence of gram-positive aerobic bacilli was reduced in the presence of C. albicans (30/176 [17.1%] versus 6/44 [13.6%]), this reduced incidence was not statistically significant. Isolation data of the subgroup of pregnant women supported these observations. CONCLUSION: Within the limitations of the study, statistically, the data suggests that an inverse relationship exists between the presence of C. albicans and recovery of Peptostreptococcus and anaerobic gram-positive cocci and bacilli. PMID:9702585

  20. Female genital tract bacterial coisolates with Candida albicans in patients without clinical vaginitis.

    PubMed

    Monif, G R; Carson, H J

    1998-01-01

    In vitro, Candida albicans has demonstrated the ability to inhibit replication of selected bacteria. Little information exists on the impact of C. albicans on the vaginal bacterial flora in vivo. The purpose of this study is to identify the coexisting bacterial flora when C. albicans is isolated from vaginal cultures submitted to a hospital-based testing facility for reasons other than vulvovaginitis. All specimens (240) received from ambulatory care clinics over a six-month period were cultured for aerobic and anaerobic bacteria and Candida species. Those specimens submitted for cervicitis, vaginitis, or vaginal discharge and those from which yeasts other than C. albicans were isolated were eliminated. To control for sample biases, a subgroup composed of all pregnant women for whom cultures were done as screening procedures was similarly studied. Chi-square analyses, comparing the prevalence of individual bacteria isolated with and without the presence of C. albicans, were done for all study populations using SPSS for Windows software (1994). Two hundred and forty consecutive specimens were bacteriologically analyzed. Of the 220 vaginal samples used in the study, C. albicans was isolated in 44 instances (20%). Neither the presence of the lactobacilli nor the presence of Gardnerella vaginalis markedly influenced the isolation rate of C. albicans. The group B streptococci had a greater probability of coisolation when C. albicans was present (27.3% verses 16%), but this was not statistically significant (P < 0.8). Dissociation between the presence of C. albicans and the coisolation of Peptostreptococcus species and anaerobic gram-positive cocci and/or bacilli was noted (P < 0.0819), while the incidence of gram-positive aerobic bacilli was reduced in the presence of C. albicans (30/176 [17.1%] versus 6/44 [13.6%]), this reduced incidence was not statistically significant. Isolation data of the subgroup of pregnant women supported these observations. Within the limitations of the study, statistically, the data suggests that an inverse relationship exists between the presence of C. albicans and recovery of Peptostreptococcus and anaerobic gram-positive cocci and bacilli.

  1. Evaluation of anodic behavior of commercially pure titanium in tungsten inert gas and laser welds.

    PubMed

    Orsi, Iara Augusta; Raimundo, Larica B; Bezzon, Osvaldo Luiz; Nóbilo, Mauro Antonio de Arruda; Kuri, Sebastião E; Rovere, Carlos Alberto D; Pagnano, Valeria Oliveira

    2011-12-01

    This study evaluated the resistance to corrosion in welds made with Tungsten Inert Gas (TIG) in specimens made of commercially pure titanium (cp Ti) in comparison with laser welds. A total of 15 circular specimens (10-mm diameter, 2-mm thick) were fabricated and divided into two groups: control group-cp Ti specimens (n = 5); experimental group-cp Ti specimens welded with TIG (n = 5) and with laser (n = 5). They were polished mechanically, washed with isopropyl alcohol, and dried with a drier. In the anodic potentiodynamic polarization assay, measurements were taken using a potentiostat/galvanostat in addition to CorrWare software for data acquisition and CorrView for data visualization and treatment. Three curves were made for each working electrode. Corrosion potential values were statistically analyzed by the Student's t-test. Statistical analysis showed that corrosion potentials and passive current densities of specimens welded with TIG are similar to those of the control group, and had lower values than laser welding. TIG welding provided higher resistance to corrosion than laser welding. Control specimens welded with TIG were more resistant to local corrosion initiation and propagation than those with laser welding, indicating a higher rate of formation and growth of passive film thickness on the surfaces of these alloys than on specimens welded with laser, making it more difficult for corrosion to occur. © 2011 by the American College of Prosthodontists.

  2. Characterization of Human Rib Biomechanical Responses due to Three-Point Bending.

    PubMed

    Kalra, Anil; Saif, Tal; Shen, Ming; Jin, Xin; Zhu, Feng; Begeman, Paul; Yang, King H; Millis, Scott

    2015-11-01

    In the elderly population, rib fracture is one of the most common injuries sustained in motor vehicle crashes. The current study was conducted to predict the biomechanical fracture responses of ribs with respect to age, gender, height, weight and percentage of ash content. Three-point bending experiments were conducted on 278 isolated rib samples extracted from 82 cadaver specimens (53 males and 29 females between the ages of 21 and 87 years) for 6th and 7th levels of ribs. Statistical analyses were carried out to identify differences based on age and gender. It was found that, in comparison to males, females had significantly lower values for maximum bending moments, slopes of bending moment-angle curves, and average cortical-bone thickness (p<0.05). Samples of ribs taken from elderly specimens failed at lower values of fracture moments than those from younger specimens, and had lower slopes of bending moment-angle curves, both in males and females (p<0.05). The generalized estimated equations were developed to predict the values of biomechanical response and average cortical thickness based on age, gender, height and weight of individual specimens. Results from the current study illustrate that biomechanical responses and rib cortical thicknesses are functions of age, gender, height and weight. However, the current study is limited to a quasi-static loading scheme, which is different from real crash conditions. Hence, rib-material properties, which are dependent on strain rate, and are needed for wholebody finite element models representing different populations, still require more research.

  3. Observations of Fabric Development in Polycrystalline Ice at Basal Pressures: Methods and Initial Results

    NASA Astrophysics Data System (ADS)

    Breton, D. J.; Baker, I.; Cole, D. M.

    2012-12-01

    Understanding and predicting the flow of polycrystalline ice is crucial to ice sheet modeling and paleoclimate reconstruction from ice cores. Ice flow rates depend strongly on the fabric (i.e. the distribution of grain sizes and crystallographic orientations) which evolves over time and enhances the flow rate in the direction of applied stress. The mechanisms for fabric evolution in ice have been extensively studied at atmospheric pressures, but little work has been done to observe these processes at the high pressures experienced deep within ice sheets where long-term changes in ice rheology are expected to have significance. We conducted compressive creep tests on a 917 kg m-3 polycrystalline ice specimen at 20 MPa hydrostatic pressure, thus simulating ~2,000 m depth. Initial specimen grain orientations were random, typical grain diameters were 1.2 mm, and the applied creep stress was 0.3 MPa. Subsequent microstructural analyses on the deformed specimen and a similarly prepared, undeformed specimen allowed characterization of crystal fabric evolution under pressure. Our microstructural analysis technique simultaneously collected grain shape and size data from Scanning Electron Microscope (SEM) micrographs and obtained crystallographic orientation data via Electron BackScatter Diffraction (EBSD). Combining these measurements allows rapid analysis of the ice fabric over large numbers of grains, yielding statistically useful numbers of grain size and full c- and a-axis grain orientation data. The combined creep and microstructural data demonstrate pressure-dependent effects on the mechanical and microstructural evolution of polycrystalline ice. We discuss possible mechanisms for the observed phenomena, and future directions for hydrostatic creep testing.

  4. Evaluation of Vickers hardness of bulk-fill composites cured by different light sources

    NASA Astrophysics Data System (ADS)

    Bakhsh, Turki A.; Yagmoor, Mohammed A.; Alsadi, Fahad M.; Jamleh, Ahmad

    2016-02-01

    [Objective] The current in vitro study was performed to evaluate Vickers hardness (VHN) of two different composite resins that were cured by using two different light curing units. [Materials and Methods] Porcelain tube samplers were used to fabricate composite cylinders from either Tetric Evoceram BulkFill (BF; Ivoclar/Vivadent, USA) or SonicFill composite (SF; Kerr, USA). Each composite type had 12 cylindrical specimens, and each specimen was cured with either Blue-phase N light-cure (Bp; Polywave, Ivoclar/Vivadent, USA) or Elipar S10 (El; Monowave, 3M ESPE, Germany). The VHN data were analyzed and tested by using Mann-Whitney U test at a significance level of 5%. [Results] Statistical analyses demonstrated an interaction between the type of composite and the type of light curing source. Significant differences (P<0.05) were recorded for all groups with higher VHN hardness of SF-El and lowest for BF-El. [Conclusions] It can be concluded that the surface hardness of bulk-fill composite is not dependent on the type of light-cure. This research was supported by King Abdulaziz University.

  5. Three-Dimensional, Inelastic Response of Single-Edge Notch Bend Specimens Subjected to Impact Loading

    DTIC Science & Technology

    1993-08-01

    measure the inherent fracture toughness of a material. A thor- ough understanding of the test specimen behavior is a prerequisite to the application of...measured material properties in structural applications . Three- dimensional dynamic analyses are performed for three different specimen configurations...derstanding of the test specimen behavior is a prerequisite to the application of measured ma- terial properties in structural applications . Three

  6. Effect of the specimen length on ultrasonic P-wave velocity in some volcanic rocks and limestones

    NASA Astrophysics Data System (ADS)

    Karaman, Kadir; Kaya, Ayberk; Kesimal, Ayhan

    2015-12-01

    Ultrasonic P-wave velocity (UPV) is commonly used in different fields such as civil, mining, geotechnical, and rock engineering. One of the significant parameters which affect the UPV of rock materials is likely to be the length of test cores although it is not mentioned in the literature. In this study, in order to explore the influence of the specimen length on the UPV, rock samples were collected from eight different locations in Turkey. The NX-sized core specimens having different length of 50, 75, 100, 125, and 150 mm were prepared. Before the analyses, rocks were divided into two groups in terms of their geological origins such as volcanic and chemical sedimentary (limestone) rocks. The UPV tests were carried out under dry and saturated conditions for each 200 core specimens. By evaluating the test results, it was shown that the length of the specimens significantly affects the UPV values. Based on the regression analyses, a method was developed to determine the threshold specimen length of studied rocks. Fluctuations in UPVdry and UPVsat values were generally observed for cores smaller than the threshold specimen length. In this study, the threshold specimen length was determined as 79 mm for volcanic rocks and 109 mm for limestones.

  7. Effect of cryogenic treatment on nickel-titanium endodontic instruments

    PubMed Central

    Kim, J. W.; Griggs, J. A.; Regan, J. D.; Ellis, R. A.; Cai, Z.

    2005-01-01

    Aim To investigate the effects of cryogenic treatment on nickel-titanium endodontic instruments. The null hypothesis was that cryogenic treatment would result in no changes in composition, microhardness or cutting efficiency of nickel-titanium instruments. Methodology Microhardness was measured on 30 nickel-titanium K-files (ISO size 25) using a Vicker’s indenter. Elemental composition was measured on two instruments using X-ray spectroscopy. A nickel-titanium bulk specimen was analysed for crystalline phase composition using X-ray diffraction. Half of the specimens to be used for each analysis were subjected to a cryogenic treatment in liquid nitrogen (−196 °C) for either 3 s (microhardness specimens) or 10 min (other specimens). Cutting efficiency was assessed by recording operator choice using 80 nickel-titanium rotary instruments (ProFile® 20, .06) half of which had been cryogenically treated and had been distributed amongst 14 clinicians. After conditioning by preparing four corresponding canals, each pair of instruments were evaluated for cutting efficiency by a clinician during preparation of one canal system in vitro. A Student’s t-test was used to analyse the microhardness data, and a binomial test was used to analyse the observer choice data. Composition data were analysed qualitatively. Results Cryogenically treated specimens had a significantly higher microhardness than the controls (P < 0.001; β > 0.999). Observers showed a preference for cryogenically treated instruments (61%), but this was not significant (P = 0.21). Both treated and control specimens were composed of 56% Ni, 44% Ti, 0% N (by weight) with a majority in the austenite phase. Conclusions Cryogenic treatment resulted in increased microhardness, but this increase was not detected clinically. There was no measurable change in elemental or crystalline phase composition. PMID:15910471

  8. Direct sampling of cystic fibrosis lungs indicates that DNA-based analyses of upper-airway specimens can misrepresent lung microbiota.

    PubMed

    Goddard, Amanda F; Staudinger, Benjamin J; Dowd, Scot E; Joshi-Datar, Amruta; Wolcott, Randall D; Aitken, Moira L; Fligner, Corinne L; Singh, Pradeep K

    2012-08-21

    Recent work using culture-independent methods suggests that the lungs of cystic fibrosis (CF) patients harbor a vast array of bacteria not conventionally implicated in CF lung disease. However, sampling lung secretions in living subjects requires that expectorated specimens or collection devices pass through the oropharynx. Thus, contamination could confound results. Here, we compared culture-independent analyses of throat and sputum specimens to samples directly obtained from the lungs at the time of transplantation. We found that CF lungs with advanced disease contained relatively homogenous populations of typical CF pathogens. In contrast, upper-airway specimens from the same subjects contained higher levels of microbial diversity and organisms not typically considered CF pathogens. Furthermore, sputum exhibited day-to-day variation in the abundance of nontypical organisms, even in the absence of clinical changes. These findings suggest that oropharyngeal contamination could limit the accuracy of DNA-based measurements on upper-airway specimens. This work highlights the importance of sampling procedures for microbiome studies and suggests that methods that account for contamination are needed when DNA-based methods are used on clinical specimens.

  9. Surface roughness of denture bases after immersion in fishcake vinegar solution

    NASA Astrophysics Data System (ADS)

    Kodir, K.; Tanti, I.; Odang, R. W.

    2017-08-01

    Fishcake is a common food in Palembang city and is usually eaten with fishcake vinegar sauce. Fishcake vinegar solution contains acetic acid and chloride and fluoride ions, all of which cause surface roughness on the denture base material. The objective of this study was to analyze the effect of fishcake vinegar solution on the surface roughness of heat-cured acrylic resin, thermoplastic nylon, and cobalt-chromium alloy denture bases. This laboratory-based experimental study was performed on heat-cured acrylic resins, thermoplastic nylon specimen plates formed in 15 × 10 × 1 mm shapes, and cobalt-chromium alloy specimens in cylinder forms with a 7.7 mm diameter and 17.5-mm height. Each group consisted of 10 pieces. Each specimen was immersed in a fishcake vinegar solution at 37 °C for 4 days. The surface roughness was measured using a profilometer before and after immersion. Statistical analyses showed significant (p < 0.05) changes in heat-cured acrylic resin, thermoplastic nylon, and the cobalt chromium alloy plates after immersion in a fishcake vinegar solution for 4 days. Fishcake vinegar solution affects the surface roughness of heat-cured acrylic resin, thermoplastic nylon, and cobalt-chromium alloy plates after a 4-day immersion period. The greatest surface roughness change occurred in the thermoplastic nylon plate, while the lowest change occurred in the cobalt-chromium alloy.

  10. Serological diagnosis of pneumocystosis: production of a synthetic recombinant antigen for immunodetection of Pneumocystis jirovecii.

    PubMed

    Tomás, A L; Cardoso, F; Esteves, F; Matos, O

    2016-11-08

    Diagnosis of Pneumocystis pneumonia (PcP) relies on the detection of P. jirovecii in respiratory specimens obtained by invasive techniques. Thus, the development of a serological test is urgently needed as it will allow the diagnosis of PcP using blood, an inexpensive and non-invasive specimen. This study aims to combine the production of a multi-epitope synthetic recombinant antigen (RSA) and an ELISA test for detection of anti-P. jirovecii antibodies, in order to develop a new approach for PcP diagnosis. The RSA was selected and designed based on the study of the immunogenicity of the carboxyl-terminal domain of the major surface glycoprotein. This antigen was purified and used as an antigenic tool in an ELISA technique for detection of Ig, IgG and IgM antibodies anti-P. jirovecii (patent-pending no. PT109078). Serum specimens from 88 patients previously categorized in distinct clinical subgroups and 17 blood donors, were analysed. The IgM anti-P. jirovecii levels were statistically increased in patients with PcP (p = 0.001) and the ELISA IgM anti-P. jirovecii test presented a sensitivity of 100% and a specificity of 80.8%, when associated with the clinical diagnosis criteria. This innovative approach, provides good insights about what can be done in the future serum testing for PcP diagnosis.

  11. Serological diagnosis of pneumocystosis: production of a synthetic recombinant antigen for immunodetection of Pneumocystis jirovecii

    PubMed Central

    Tomás, A. L.; Cardoso, F.; Esteves, F.; Matos, O.

    2016-01-01

    Diagnosis of Pneumocystis pneumonia (PcP) relies on the detection of P. jirovecii in respiratory specimens obtained by invasive techniques. Thus, the development of a serological test is urgently needed as it will allow the diagnosis of PcP using blood, an inexpensive and non-invasive specimen. This study aims to combine the production of a multi-epitope synthetic recombinant antigen (RSA) and an ELISA test for detection of anti-P. jirovecii antibodies, in order to develop a new approach for PcP diagnosis. The RSA was selected and designed based on the study of the immunogenicity of the carboxyl-terminal domain of the major surface glycoprotein. This antigen was purified and used as an antigenic tool in an ELISA technique for detection of Ig, IgG and IgM antibodies anti-P. jirovecii (patent-pending no. PT109078). Serum specimens from 88 patients previously categorized in distinct clinical subgroups and 17 blood donors, were analysed. The IgM anti-P. jirovecii levels were statistically increased in patients with PcP (p = 0.001) and the ELISA IgM anti-P. jirovecii test presented a sensitivity of 100% and a specificity of 80.8%, when associated with the clinical diagnosis criteria. This innovative approach, provides good insights about what can be done in the future serum testing for PcP diagnosis. PMID:27824115

  12. Effect of Ingested Liquids on Color Change of Composite Resins.

    PubMed

    Malek Afzali, Beheshteh; Ghasemi, Amir; Mirani, Asrin; Abdolazimi, Zahra; Akbarzade Baghban, Alireza; Kharazifard, Mohammad Javad

    2015-08-01

    Color change of composite restorations is well known to dentists. However, the effect of commonly consumed drinks on discoloration of composite resins has yet to be determined. This study sought to assess the color change of a nanofilled (Premise) and a flowable composite resin (Premise flowable) following simulated consumption of tea, cola, iron drops and multivitamin syrup. Forty disk-shaped specimens (7 mm in diameter and 2 mm thick) were fabricated from each composite resin. The baseline color values were measured according to the CIE L*a*b* system using digital imaging. The specimens of each restorative material were randomly divided into five groups (eight each) according to the storage media namely tea, cola, iron drops, multivitamin syrup or distilled water (control). The specimens were immersed in staining solutions for three hours daily over a 40-day test period. Following this, the color change values (ΔE*) were calculated. For statistical analyses, the color differences were analyzed using two-way ANOVA and Tukey's test (P< 0.05). There was no significant difference in ΔE* values between the two types of composite resins (P>0.05). In both composite materials, the difference among the solutions was not significant (P>0.05). Under the tested experimental conditions, both restorative materials were susceptible to discoloration by all four staining solutions. The color change values were not related to the solution or the type of material used.

  13. Creation of a virtual cutaneous tissue bank

    NASA Astrophysics Data System (ADS)

    LaFramboise, William A.; Shah, Sujal; Hoy, R. W.; Letbetter, D.; Petrosko, P.; Vennare, R.; Johnson, Peter C.

    2000-04-01

    Cellular and non-cellular constituents of skin contain fundamental morphometric features and structural patterns that correlate with tissue function. High resolution digital image acquisitions performed using an automated system and proprietary software to assemble adjacent images and create a contiguous, lossless, digital representation of individual microscope slide specimens. Serial extraction, evaluation and statistical analysis of cutaneous feature is performed utilizing an automated analysis system, to derive normal cutaneous parameters comprising essential structural skin components. Automated digital cutaneous analysis allows for fast extraction of microanatomic dat with accuracy approximating manual measurement. The process provides rapid assessment of feature both within individual specimens and across sample populations. The images, component data, and statistical analysis comprise a bioinformatics database to serve as an architectural blueprint for skin tissue engineering and as a diagnostic standard of comparison for pathologic specimens.

  14. Assessment of Hepatitis B Virus DNA Stability in Serum by the Chiron Quantiplex Branched-DNA Assay

    PubMed Central

    Krajden, Mel; Comanor, Lorraine; Rifkin, Oretta; Grigoriew, Anna; Minor, James M.; Kapke, Gordon F.

    1998-01-01

    Quantification of hepatitis B virus (HBV) DNA in serum is used to establish eligibility for treatment and to monitor therapeutic response. With the trend toward centralized testing, defining the conditions that preserve sample integrity is of paramount importance. We therefore evaluated the stability of HBV DNA in 26 previously frozen (PF) and 5 fresh, never previously frozen serum specimens. PF specimens, covering a 3-log10 HBV DNA dynamic range, were thawed and stored at −70, 4, 23, 37, and 45°C (±1.5°C) for 0, 24, 72, and 120 h (±2 h) and were refrozen at −70°C prior to testing. Five fresh specimens were split into two groups. Both group FG1 and group FG2 specimens were handled as described above; however, group FG1 specimens were subsequently maintained at 4°C and were never frozen prior to testing. Linear regression analysis of PF specimens demonstrated no significant HBV DNA degradation at ≤4°C over 5 days; however, HBV DNA levels decreased by 1.8, 3.4, and 20% per day at 23, 37, and 45°C, respectively. Three independent statistical methods confirmed that the probability of specimen failure, defined as a loss of 20% or more of HBV DNA and/or coagulation of serum, was lowest at ≤4°C and increased with temperature. Because only 10 to 20% of individual patient specimens demonstrated losses of HBV DNA of ≥20% at 23 or 37°C, sufficient numbers of serum specimens must be evaluated to determine overall statistical trends. In conclusion, HBV DNA integrity in separated serum specimens is preserved for at least 5 days when the specimens are stored at −70 or 4°C. PMID:9466745

  15. The Effect of Compressive Loading on the Fatigue Lifetime of Graphite/ Epoxy Laminates

    DTIC Science & Technology

    1979-10-01

    Un-notched 11 3 Specimen Configuration, Notched 12 4 Location of Thickness and Width Measurements 14 5 Overall View of Composite Compression Test...Grips in Universal Testing Machine 24 8 Specimen Positioning Device 26 9 "Full-Fixity" Apparatus, Showing Auxiliary Platens 26 10 Specimen and Restraint...the accumu- lation of a statistically significant data base. * IA previous research study [11 showed that graphite/epoxy composites under constant

  16. Mechanical properties of woven glass fiber-reinforced composites.

    PubMed

    Kanie, Takahito; Arikawa, Hiroyuki; Fujii, Koichi; Ban, Seiji

    2006-06-01

    The aim of this investigation was to measure the flexural and compressive strengths and the corresponding moduli of cylindrical composite specimens reinforced with woven glass fiber. Test specimens were made by light-curing urethane dimethacrylate oligomer with woven glass fiber of 0.18-mm standard thickness. Tests were conducted using four reinforcement methods and two specimen diameters. Flexural strength and modulus of woven glass fiber-reinforced specimens were significantly greater than those without woven glass fiber (p < 0.01). Likewise, compressive strength of reinforced specimens was significantly greater than those without woven glass fiber (p < 0.01), except for specimens reinforced with woven glass fiber oriented at a tilt direction in the texture (p > 0.05). In terms of comparison between the two specimen diameters, no statistically significant differences in flexural strength and compressive strength (p > 0.05) were observed.

  17. Osteoblast response to porous titanium and biomimetic surface: In vitro analysis.

    PubMed

    Prado, Renata Falchete do; de Oliveira, Fernanda Saraiva; Nascimento, Rodrigo Dias; de Vasconcellos, Luana Marotta Reis; Carvalho, Yasmin Rodarte; Cairo, Carlos Alberto Alves

    2015-01-01

    This study analyzed the behavior of human osteoblasts cultured on porous titanium specimens, with and without biomimetic treatment, compared to dense titanium. The experiment had seven groups: Group 1: cells cultured on polystyrene of culture plate wells; Group 2: cells cultured on dense titanium specimen; Group 3: specimen with 33.79% of pores; Group 4: 41.79% of pores; Groups 5, 6 and 7: specimens similar to groups 2, 3 and 4, yet with biomimetic treatment. Real time-polymerase chain reaction with reverse transcription of the following genes was performed: prostaglandin E2 synthase, integrin β1, osterix, Runx2, Interleukin 6, macrophage colony stimulating factor, apolipoprotein E and others. The study achieved data on cell adhesion, growth and viability, total protein content, alkaline phosphatase activity and quantity of mineralized nodule formations. Data were statistically evaluated. Adherent cells and alkaline phosphatase activity were similar in titanium specimens, regardless of the groups. Biomimetic treatment reduced the total protein activity and the viability of tested cells. Most tested genes had statistically similar expression in all groups. The tested porosities did not cause alterations in osteoblast behavior and the biomimetic treatment impaired the biocompatibility of titanium causing cytotoxicity. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. PCA Based Stress Monitoring of Cylindrical Specimens Using PZTs and Guided Waves

    PubMed Central

    Mujica, Luis; Ruiz, Magda; Camacho, Johanatan

    2017-01-01

    Since mechanical stress in structures affects issues such as strength, expected operational life and dimensional stability, a continuous stress monitoring scheme is necessary for a complete integrity assessment. Consequently, this paper proposes a stress monitoring scheme for cylindrical specimens, which are widely used in structures such as pipelines, wind turbines or bridges. The approach consists of tracking guided wave variations due to load changes, by comparing wave statistical patterns via Principal Component Analysis (PCA). Each load scenario is projected to the PCA space by means of a baseline model and represented using the Q-statistical indices. Experimental validation of the proposed methodology is conducted on two specimens: (i) a 12.7 mm (1/2″) diameter, 0.4 m length, AISI 1020 steel rod, and (ii) a 25.4 mm (1″) diameter, 6m length, schedule 40, A-106, hollow cylinder. Specimen 1 was subjected to axial loads, meanwhile specimen 2 to flexion. In both cases, simultaneous longitudinal and flexural guided waves were generated via piezoelectric devices (PZTs) in a pitch-catch configuration. Experimental results show the feasibility of the approach and its potential use as in-situ continuous stress monitoring application. PMID:29194384

  19. [Toxicity and toxin profiles of xanthid crabs collected around Nakanoshima in the Tokara Islands, Japan].

    PubMed

    Sagara, Takefumi; Taniyama, Shigeto; Takatani, Tomohiro; Nishibori, Naoyoshi; Nishio, Sachio; Noguchi, Tamao; Arakawa, Osamu

    2009-10-01

    A total of 36 specimens of 5 xanthid crab species, Zosimus aeneus (n=16), Xanthias lividus (n=4), Leptodius sanguineus (n=3), Daira perlata (n=10) and Eriphia sebana (n=3), were collected around Nakanoshima Island, which is located at the northeastern part of the Tokara Islands, Kagoshima Prefecture, Japan in May and July 2000, and their toxicity was determined by mouse bioassay. Nine of 16 Z. aeneus specimens and all of 4 X. lividus specimens showed lethal potency to mice (2.1-11 MU/g, 2.8-8.6 MU/g, respectively), whereas all the other species were non-toxic (less than 2.0 MU/g). LC/MS analyses indicated that the toxin of the Z. aeneus specimens was mainly composed of tetrodotoxin (41% of total toxicity), and 11-oxotetrodotoxin contributed to the remaining toxicity. The toxin of the X. lividus specimens, however, was apparently not tetrodotoxin. In HPLC-FLD analyses, no paralytic shellfish poison component was detected in either of the two toxic species.

  20. Prognostic value of cell cycle regulatory proteins in muscle-infiltrating bladder cancer.

    PubMed

    Galmozzi, Fabia; Rubagotti, Alessandra; Romagnoli, Andrea; Carmignani, Giorgio; Perdelli, Luisa; Gatteschi, Beatrice; Boccardo, Francesco

    2006-12-01

    The aims of this study were to investigate the expression levels of proteins involved in cell cycle regulation in specimens of bladder cancer and to correlate them with the clinicopathological characteristics, proliferative activity and survival. Eighty-two specimens obtained from patients affected by muscle-invasive bladder cancer were evaluated immunohistochemically for p53, p21 and cyclin D1 expression, as well as for the tumour proliferation index, Ki-67. The statistical analysis included Kaplan-Meier curves with log-rank test and Cox proportional hazards models. In univariate analyses, low Ki-67 proliferation index (P = 0.045) and negative p21 immunoreactivity (P = 0.04) were associated to patient's overall survival (OS), but in multivariate models p21 did not reach statistical significance. When the combinations of the variables were assessed in two separate multivariate models that included tumour stage, grading, lymph node status, vascular invasion and perineural invasion, the combined variables p21/Ki-67 or p21/cyclin D1 expression were independent predictors for OS; in particular, patients with positive p21/high Ki-67 (P = 0.015) or positive p21/negative cyclin D1 (P = 0.04) showed the worst survival outcome. Important alterations in the cell cycle regulatory pathways occur in muscle-invasive bladder cancer and the combined use of cell cycle regulators appears to provide significant prognostic information that could be used to select the patients most suitable for multimodal therapeutic approaches.

  1. Training in metabolomics research. II. Processing and statistical analysis of metabolomics data, metabolite identification, pathway analysis, applications of metabolomics and its future.

    PubMed

    Barnes, Stephen; Benton, H Paul; Casazza, Krista; Cooper, Sara J; Cui, Xiangqin; Du, Xiuxia; Engler, Jeffrey; Kabarowski, Janusz H; Li, Shuzhao; Pathmasiri, Wimal; Prasain, Jeevan K; Renfrow, Matthew B; Tiwari, Hemant K

    2016-08-01

    Metabolomics, a systems biology discipline representing analysis of known and unknown pathways of metabolism, has grown tremendously over the past 20 years. Because of its comprehensive nature, metabolomics requires careful consideration of the question(s) being asked, the scale needed to answer the question(s), collection and storage of the sample specimens, methods for extraction of the metabolites from biological matrices, the analytical method(s) to be employed and the quality control of the analyses, how collected data are correlated, the statistical methods to determine metabolites undergoing significant change, putative identification of metabolites and the use of stable isotopes to aid in verifying metabolite identity and establishing pathway connections and fluxes. This second part of a comprehensive description of the methods of metabolomics focuses on data analysis, emerging methods in metabolomics and the future of this discipline. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  2. A comparison of the relative efficacies of four hand and rotary instrumentation techniques during endodontic retreatment.

    PubMed

    Imura, N; Kato, A S; Hata, G I; Uemura, M; Toda, T; Weine, F

    2000-07-01

    The purpose of this study was to quantify the amount of remaining gutta-percha/scaler on the walls of root canals when two engine-driven instruments (Quantec and ProFile) and two hand instruments (K-file and Hedström file) were used to remove these materials. The amount of apically extruded debris and the time required for treatment were also recorded. One hundred extracted mandibular premolars were prepared using a modified step-back, flare technique and obturated with the lateral condensation technique. After repreparation with the test instruments, the specimens were cut transversally at the cervical, middle and apical thirds with steel discs and the three sections were split longitudinally. The amount of residual debris on the canal walls in each section was examined using a stereomicroscope. In all groups the cervical and middle thirds showed no debris. In the apical third, obturating material was observed in some specimens. No statistically significant difference was found between the two groups for incidence of debris, although the Hedström group showed a greater number of samples with remaining gutta-percha/sealer. When analysing dirty specimens only, there was a statistically significant difference between the four groups (P < 0.01) with the Hedström group having significantly less length of canal wall with remaining obturation material than the Quantec group. There was no significant difference amongst the groups for weight of extruded debris. However, there was a significant difference amongst the groups for mean treatment time with the Hedström file group requiring significantly less time than the Quantec group (P < 0.001); no significant differences were found between the other groups. Six instruments fractured in the Quantec group, four in the ProFile group, two in the Hedström group and two in the K-type group. The results showed that overall, all instruments may leave filling material inside the root canal. During retreatment there is a risk of instrument breakage, especially rotary instruments.

  3. Distal radius: anatomical morphometric gender characteristics. Do anatomical pre-shaped plates pay attention on it?

    PubMed

    Oppermann, Johannes; Bredow, Jan; Beyer, Frank; Neiss, Wolfram Friedrich; Spies, Christian K; Eysel, Peer; Dargel, Jens; Wacker, Max

    2015-01-01

    The purpose of the study was to investigate differences in the osseous structure anatomy of male and female distal radii. Morphometric data were obtained of 49 distal human cadaveric radii. An imprint of the distal edge was attained using silicone mass and the palmar cortical angle (PCA) of the lateral and intermediate column, here declared as medial, according to the concept of Rikli and Rigazzoni. The lateral and medial length and five widths were digitally measured by three observers. In order to compare the measurements an unpaired t test was used. To prove the reliability of the measurements an intraclass correlation analyses was done. Overall mean medial PCA was 148.25° (SD ± 6.83) and mean lateral PCA 156.07° (SD ± 7.00). In male specimens, the mean medial PCA was 147.38° (SD ± 6.01) and mean lateral PCA was 153.6° (SD ± 6.20) whereas in female specimens, the mean medial PCA was 149.41° (SD ± 7.79) and the mean lateral PCA 159.37° (SD ± 6.78), with statistical significance for the female lateral PCA. No gender significant difference for the medial PCA and no significant side difference for the PCA's could be found. The ICC of the observers was r = 0.936 and 0.976 for the medial and for lateral PCA 0.957-0.984. The palmar cortical length of the distal radius was significantly longer in male specimens. For all widths, larger values for male radii were measured, being statistically significant in all cases. Male dimensions concerning the wide were significantly larger when compared with females. Regarding the PCA at the medial and lateral column, we found significant difference for lateral PCA concerning the gender. Overall, study results demonstrated an angle of 148.25° ± 6.83 for the medial PCA and 156.07° ± 7.00 for the lateral PCA.

  4. Effect of bleaching on microhardness of esthetic restorative materials.

    PubMed

    Malkondu, Özlem; Yurdagüven, Haktan; Say, Esra Can; Kazazoğlu, Ender; Soyman, Mübin

    2011-01-01

    This study evaluated the effect of a high-concentration carbamide peroxide–containing home bleaching system (Opalescence PF) and a hydrogen peroxide–containing over-the-counter bleaching system (Treswhite Supreme) on the microhardness of two nanocomposites (Filtek Supreme XT and Premise) and leucite-reinforced glass ceramic (Empress Esthetic), glass ceramic (Empress 2 layering), and feldspathic porcelain (Matchmaker MC). A total of 100 specimens, 20 of each kind of the restorative materials, 2 mm in thickness and 10 mm in diameter, were fabricated. Then the specimens were polished with SiC paper and 1 μm alumina polishing paste. After polishing, porcelain specimens were glazed in accordance with the manufacturer's instructions. Each type of restorative material was then randomly divided into two groups (n=10), and the specimens were treated with either Opalescence PF or Treswhite Supreme. The microhardness of the specimens before bleaching (baseline) and after bleaching was determined using a digital microhardness tester. Data were analyzed using the Mann-Whitney U-test and the Wilcoxon test. Opalescence PF significantly influenced the hardness of all the restorative materials. Statistically significant decreases with respect to before bleaching were found for Premise (p=0.005), Empress Esthetic (p=0.003), Empress 2 layering (p=0.005), and Matchmaker-MC (p=0.003), whereas a statistically significant increase was observed in Filtek Supreme XT (p=0.028). The difference in the microhardness values between before and after bleaching using Treswhite Supreme was statistically significant only for Premise (p=0.022). High-concentration carbamide peroxide–containing home bleaching may affect the microhardness of restorative materials.

  5. Multivariate two-part statistics for analysis of correlated mass spectrometry data from multiple biological specimens.

    PubMed

    Taylor, Sandra L; Ruhaak, L Renee; Weiss, Robert H; Kelly, Karen; Kim, Kyoungmi

    2017-01-01

    High through-put mass spectrometry (MS) is now being used to profile small molecular compounds across multiple biological sample types from the same subjects with the goal of leveraging information across biospecimens. Multivariate statistical methods that combine information from all biospecimens could be more powerful than the usual univariate analyses. However, missing values are common in MS data and imputation can impact between-biospecimen correlation and multivariate analysis results. We propose two multivariate two-part statistics that accommodate missing values and combine data from all biospecimens to identify differentially regulated compounds. Statistical significance is determined using a multivariate permutation null distribution. Relative to univariate tests, the multivariate procedures detected more significant compounds in three biological datasets. In a simulation study, we showed that multi-biospecimen testing procedures were more powerful than single-biospecimen methods when compounds are differentially regulated in multiple biospecimens but univariate methods can be more powerful if compounds are differentially regulated in only one biospecimen. We provide R functions to implement and illustrate our method as supplementary information CONTACT: sltaylor@ucdavis.eduSupplementary information: Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  6. Reliability of void detection in structural ceramics using scanning laser acoustic microscopy

    NASA Technical Reports Server (NTRS)

    Roth, D. J.; Klima, S. J.; Kiser, J. D.; Baaklini, G. Y.

    1985-01-01

    The reliability of scanning laser acoustic microscopy (SLAM) for detecting surface voids in structural ceramic test specimens was statistically evaluated. Specimens of sintered silicon nitride and sintered silicon carbide, seeded with surface voids, were examined by SLAM at an ultrasonic frequency of 100 MHz in the as fired condition and after surface polishing. It was observed that polishing substantially increased void detectability. Voids as small as 100 micrometers in diameter were detected in polished specimens with 0.90 probability at a 0.95 confidence level. In addition, inspection times were reduced up to a factor of 10 after polishing. The applicability of the SLAM technique for detection of naturally occurring flaws of similar dimensions to the seeded voids is discussed. A FORTRAN program listing is given for calculating and plotting flaw detection statistics.

  7. Problems Associated with Statistical Pattern Recognition of Acoustic Emission Signals in a Compact Tension Fatigue Specimen

    NASA Technical Reports Server (NTRS)

    Hinton, Yolanda L.

    1999-01-01

    Acoustic emission (AE) data were acquired during fatigue testing of an aluminum 2024-T4 compact tension specimen using a commercially available AE system. AE signals from crack extension were identified and separated from noise spikes, signals that reflected from the specimen edges, and signals that saturated the instrumentation. A commercially available software package was used to train a statistical pattern recognition system to classify the signals. The software trained a network to recognize signals with a 91-percent accuracy when compared with the researcher's interpretation of the data. Reasons for the discrepancies are examined and it is postulated that additional preprocessing of the AE data to focus on the extensional wave mode and eliminate other effects before training the pattern recognition system will result in increased accuracy.

  8. A scanning electron microscope study and statistical analysis of adipocyte morphology in lipofilling: comparing the effects of harvesting and purification procedures with 2 different techniques.

    PubMed

    Rubino, Corrado; Mazzarello, Vittorio; Faenza, Mario; Montella, Andrea; Santanelli, Fabio; Farace, Francesco

    2015-06-01

    The aim of this study was to evaluate the effects on adipocyte morphology of 2 techniques of fat harvesting and of fat purification in lipofilling, considering that the number of viable healthy adipocytes is important in fat survival in recipient areas of lipofilling. Fat harvesting was performed in 10 female patients from flanks, on one side with a 2-mm Coleman cannula and on the other side with a 3-mm Mercedes cannula. Thirty milliliter of fat tissue from each side was collected and divided into three 10 mL syringes: A, B, and C. The fat inside syringe A was left untreated, the fat in syringe B underwent simple sedimentation, and the fat inside syringe C underwent centrifugation at 3000 rpm for 3 minutes. Each fat graft specimen was processed for examination under low-vacuum scanning electron microscope. Diameter (μ) and number of adipocytes per square millimeter and number of altered adipocytes per square millimeter were evaluated. Untreated specimens harvested with the 2 different techniques were first compared, then sedimented versus centrifuged specimens harvested with the same technique were compared. Statistical analysis was performed using Wilcoxon signed rank test. The number of adipocytes per square millimeter was statistically higher in specimens harvested with the 3-mm Mercedes cannula (P = 0.0310). The number of altered cells was statistically higher in centrifuged specimens than in sedimented ones using both methods of fat harvesting (P = 0.0080) with a 2-mm Coleman cannula and (P = 0.0050) with a 3-mm Mercedes cannula. Alterations in adipocyte morphology consisted in wrinkling of the membrane, opening of pore with leakage of oily material, reduction of cellular diameter, and total collapse of the cellular membrane. Fat harvesting by a 3-mm cannula results in a higher number of adipocytes and centrifugation of the harvested fat results in a higher number of morphologic altered cells than sedimentation.

  9. Morphometric and molecular analyses of the sand fly species Lutzomyia shannoni (Diptera: Psychodidae: Phlebotominae) collected from seven different geographical areas in the southeastern United States.

    PubMed

    Florin, David A; Davies, Stephen J; Olsen, Cara; Lawyer, Phillip; Lipnick, Robert; Schultz, George; Rowton, Edgar; Wilkerson, Richard; Keep, Lisa

    2011-03-01

    A morphometric and molecular study of adult male and female Lutzomyia shannoni (Dyar 1929) collected at seven different locations within the southeastern United States was conducted to assess the degree of divergence between the grouped specimens from each location. The collection locations were as follows: Fort Bragg, NC; Fort Campbell, KY; Fort Rucker, AL; Ossabaw Island, GA; Patuxent National Wildlife Research Refuge, MD; Suwannee National Wildlife Refuge, FL; and Baton Rouge, LA. Forty males and forty females from each location were analyzed morphometrically from 54 and 49 character measurements, respectively. In addition, the molecular markers consisting of the partial cytochrome c oxidase subunit I (from 105 sand flies: 15 specimens/collection site) and the partial internal transcribed spacer 2 (from 42 sand flies: six specimens/collection site) were compared. Multivariate analyses indicate that the low degree of variation between the grouped specimens from each collection site prevents the separation of any collection site into an entity that could be interpreted as a distinct population. The molecular analyses were in concordance with the morphometric study as no collection location grouped into a separate population based on the two partial markers. The grouped specimens from each collection site appear to be within the normal variance of the species, indicating a single population in the southeast United States. It is recommended that additional character analyses of L. shannoni based on more molecular markers, behavioral, ecological, and physiological characteristics, be conducted before ruling out the possibility of populations or a cryptic species complex within the southeastern United States.

  10. Flat tensile specimen design for advanced composites

    NASA Technical Reports Server (NTRS)

    Worthem, Dennis W.

    1990-01-01

    Finite element analyses of flat, reduced gage section tensile specimens with various transition region contours were performed. Within dimensional constraints, such as maximum length, tab region width, gage width, gage length, and minimum tab length, a transition contour radius of 41.9 cm produced the lowest stress values in the specimen transition region. The stresses in the transition region were not sensitive to specimen material properties. The stresses in the tab region were sensitive to specimen composite and/or tab material properties. An evaluation of stresses with different specimen composite and tab material combinations must account for material nonlinearity of both the tab and the specimen composite. Material nonlinearity can either relieve stresses in the composite under the tab or elevate them to cause failure under the tab.

  11. A revision of chiggers of the minuta species-group (Acari: Trombiculidae: Neotrombicula Hirst, 1925) using multivariate morphometrics.

    PubMed

    Stekolnikov, Alexandr A; Klimov, Pavel B

    2010-09-01

    We revise chiggers belonging to the minuta-species group (genus Neotrombicula Hirst, 1925) from the Palaearctic using size-free multivariate morphometrics. This approach allowed us to resolve several diagnostic problems. We show that the widely distributed Neotrombicula scrupulosa Kudryashova, 1993 forms three spatially and ecologically isolated groups different from each other in size or shape (morphometric property) only: specimens from the Caucasus are distinct from those from Asia in shape, whereas the Asian specimens from plains and mountains are different from each other in size. We developed a multivariate classification model to separate three closely related species: N. scrupulosa, N. lubrica Kudryashova, 1993 and N. minuta Schluger, 1966. This model is based on five shape variables selected from an initial 17 variables by a best subset analysis using a custom size-correction subroutine. The variable selection procedure slightly improved the predictive power of the model, suggesting that it not only removed redundancy but also reduced 'noise' in the dataset. The overall classification accuracy of this model is 96.2, 96.2 and 95.5%, as estimated by internal validation, external validation and jackknife statistics, respectively. Our analyses resulted in one new synonymy: N. dimidiata Stekolnikov, 1995 is considered to be a synonym of N. lubrica. Both N. scrupulosa and N. lubrica are recorded from new localities. A key to species of the minuta-group incorporating results from our multivariate analyses is presented.

  12. An Experimental Study of the Fracture Coalescence Behaviour of Brittle Sandstone Specimens Containing Three Fissures

    NASA Astrophysics Data System (ADS)

    Yang, S. Q.; Yang, D. S.; Jing, H. W.; Li, Y. H.; Wang, S. Y.

    2012-07-01

    To analyse the fracture coalescence behaviour of rock, rectangular prismatic sandstone specimens (80 × 160 × 30 mm in size) containing three fissures were tested under uniaxial compression. The strength and deformation behaviours of the specimens are first analysed by investigating the effects of the ligament angle β2 on the peak strength, peak strain and crack initiation stress of the specimens. To confirm the sequence of crack coalescence, a photographic monitoring technique is used throughout the entire period of deformation. Based on the results, the relationship between the real-time crack coalescence process and the axial stress-strain curve of brittle sandstone specimens is also developed, and this relationship can be used to evaluate the macroscopic deformation characteristics of pre-cracked rock. The equivalent strain evolution fields of the specimen, with α = β1 = 45° and β2 = 90°, are obtained using the digital image correlation technique and show good agreement with the experimental results of pre-cracked brittle sandstone. These experimental results are expected to improve the understanding of fracture mechanisms and be used in rock engineering with intermittent structures, such as deep underground excavated tunnels.

  13. Evaluation of the effect of a home-bleaching agent on the surface characteristics of indirect esthetic restorative materials: part I--roughness.

    PubMed

    Torabi, Kianoosh; Rasaeipour, Sasan; Khaledi, Amir Alireza; Vojdani, Mahroo; Ghodsi, Safoura

    2014-05-01

    Pressing esthetic demands of good looking make people undergo bleaching procedures. However, the effect of bleaching agents on esthetic restorative materials with different surface preparations has been poorly studied. The aim of this study was to examine the effect of a homebleaching agent (carbamide peroxide: CP 38%) on the surface roughness of the polished fiber reinforced composite (FRC), overglazed, autoglazed, or polished ceramic samples. Twenty standardized cylindrical specimens were made of each of the following groups: over-glazed, autoglazed, polished porcelain and also FRC. The test specimens exposed to the CP 38%, 15 minutes, twice a day for 2 weeks according to the manufacturer's recommendation. Six samples from each group were selected randomly to form negative controls. Surface roughness measurements (Ra, micrometer) for baseline, test and control specimens were performed by use of a profilometer. Paired t-test, Mann-Whitney test, and Kruskal-Wallis test were used for statistical analyses. The data showed that bleaching with CP 38% significantly increased the surface roughness of all the test samples (p < 0.05). The type of surface preparation caused significant differences between the susceptibility of porcelain subgroups to bleaching (p < 0.05). The polished porcelain specimens showed the highest changes after bleaching. CP 38% significantly increases the surface roughness of the porcelains and FRC. The type of surface condition affects the amenability of the porcelain surface to the bleaching agent. Glazed porcelains were more resistant to roughness than the polished porcelains and also the composite. Roughening of porcelain and FRC occur following bleaching procedure. No special surface preparation of indirect esthetic restorative materials can completely preserve these materials from adverse effects of bleaching agents.

  14. Influence of various metal oxides on mechanical and physical properties of heat-cured polymethyl methacrylate denture base resins.

    PubMed

    Asar, Neset Volkan; Albayrak, Hamdi; Korkmaz, Turan; Turkyilmaz, Ilser

    2013-08-01

    To evaluate the effect of various metal oxides on impact strength (IS), fracture toughness (FT), water sorption (WSP) and solubility (WSL) of heat-cured acrylic resin. Fifty acrylic resin specimens were fabricated for each test and divided into five groups. Group 1 was the control group and Group 2, 3, 4 and 5 (test groups) included a mixture of 1% TiO2 and 1% ZrO2, 2% Al2O3, 2% TiO2, and 2% ZrO2 by volume, respectively. Rectangular unnotched specimens (50 mm × 6.0 mm × 4.0 mm) were fabricated and droptower impact testing machine was used to determine IS. For FT, compact test specimens were fabricated and tests were done with a universal testing machine with a cross-head speed of 5 mm/min. For WSP and WSL, discshaped specimens were fabricated and tests were performed in accordance to ISO 1567. ANOVA and Kruskal-Wallis tests were used for statistical analyses. IS and FT values were significantly higher and WSP and WSL values were significantly lower in test groups than in control group (P<.05). Group 5 had significantly higher IS and FT values and significantly lower WSP values than other groups (P<.05) and provided 40% and 30% increase in IS and FT, respectively, compared to control group. Significantly lower WSL values were detected for Group 2 and 5 (P<.05). Modification of heat-cured acrylic resin with metal oxides, especially with ZrO2, may be useful in preventing denture fractures and undesirable physical changes resulting from oral fluids clinically.

  15. Advanced Statistical Analyses to Reduce Inconsistency of Bond Strength Data.

    PubMed

    Minamino, T; Mine, A; Shintani, A; Higashi, M; Kawaguchi-Uemura, A; Kabetani, T; Hagino, R; Imai, D; Tajiri, Y; Matsumoto, M; Yatani, H

    2017-11-01

    This study was designed to clarify the interrelationship of factors that affect the value of microtensile bond strength (µTBS), focusing on nondestructive testing by which information of the specimens can be stored and quantified. µTBS test specimens were prepared from 10 noncarious human molars. Six factors of µTBS test specimens were evaluated: presence of voids at the interface, X-ray absorption coefficient of resin, X-ray absorption coefficient of dentin, length of dentin part, size of adhesion area, and individual differences of teeth. All specimens were observed nondestructively by optical coherence tomography and micro-computed tomography before µTBS testing. After µTBS testing, the effect of these factors on µTBS data was analyzed by the general linear model, linear mixed effects regression model, and nonlinear regression model with 95% confidence intervals. By the general linear model, a significant difference in individual differences of teeth was observed ( P < 0.001). A significantly positive correlation was shown between µTBS and length of dentin part ( P < 0.001); however, there was no significant nonlinearity ( P = 0.157). Moreover, a significantly negative correlation was observed between µTBS and size of adhesion area ( P = 0.001), with significant nonlinearity ( P = 0.014). No correlation was observed between µTBS and X-ray absorption coefficient of resin ( P = 0.147), and there was no significant nonlinearity ( P = 0.089). Additionally, a significantly positive correlation was observed between µTBS and X-ray absorption coefficient of dentin ( P = 0.022), with significant nonlinearity ( P = 0.036). A significant difference was also observed between the presence and absence of voids by linear mixed effects regression analysis. Our results showed correlations between various parameters of tooth specimens and µTBS data. To evaluate the performance of the adhesive more precisely, the effect of tooth variability and a method to reduce variation in bond strength values should also be considered.

  16. Assessment of MALDI-TOF MS biotyping for Borrelia burgdorferi sl detection in Ixodes ricinus

    PubMed Central

    Boyer, Pierre H.; Boulanger, Nathalie; Nebbak, Amira; Collin, Elodie; Jaulhac, Benoit; Almeras, Lionel

    2017-01-01

    Matrix Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS) has been demonstrated to be useful for tick identification at the species level. More recently, this tool has been successfully applied for the detection of bacterial pathogens directly in tick vectors. The present work has assessed the detection of Borrelia burgdorferi sensu lato in Ixodes ricinus tick vector by MALDI-TOF MS. To this aim, experimental infection model of I. ricinus ticks by B. afzelii was carried out and specimens collected in the field were also included in the study. Borrelia infectious status of I. ricinus ticks was molecularly controlled using half-idiosome to classify specimens. Among the 39 ticks engorged on infected mice, 14 were confirmed to be infected by B. afzelii. For field collection, 14.8% (n = 12/81) I. ricinus ticks were validated molecularly as infected by B. burgdorferi sl. To determine the body part allowing the detection of MS protein profile changes between non-infected and B. afzelii infected specimens, ticks were dissected in three compartments (i.e. 4 legs, capitulum and half-idiosome) prior to MS analysis. Highly reproducible MS spectra were obtained for I. ricinus ticks according to the compartment tested and their infectious status. However, no MS profile change was found when paired body part comparison between non-infected and B. afzelii infected specimens was made. Statistical analyses did not succeed to discover, per body part, specific MS peaks distinguishing Borrelia-infected from non-infected ticks whatever their origins, laboratory reared or field collected. Despite the unsuccessful of MALDI-TOF MS to classify tick specimens according to their B. afzelii infectious status, this proteomic tool remains a promising method for rapid, economic and accurate identification of tick species. Moreover, the singularity of MS spectra between legs and half-idiosome of I. ricinus could be used to reinforce this proteomic identification by submission of both these compartments to MS. PMID:28950023

  17. The effect of instrument lubricant on the diametral tensile strength and water uptake of posterior composite restorative material.

    PubMed

    Patel, J; Granger, C; Parker, S; Patel, M

    2017-01-01

    This in-vitro study investigated the effect of 'instrument lubricants' used during placement of composite restorative material, on the diametral tensile strength (DTS) and water uptake of composite specimens. 300 posterior composite cylindrical specimens were manufactured: 60 with each instrument lubricant (ethanol, 3-step, 2-step and 1-step 'bonding agent') and 60 with no lubricant (controls). Each set of 60 specimens was evenly allocated to one of the following test groups (n=100/group): Group 1 - tested for DTS immediately after manufacture; Groups 2 and 3 - tested for DTS after immersion in phosphate-buffered saline (PBS) for 1 and 12-weeks respectively, using a Universal Instron machine. Water uptake was assessed gravimetrically. Data were statistically analysed with two-way ANOVA and Tukey's post hoc test (α=0.05). The mean DTS and percentage weight change of composite specimens ranged between 32.49-53.14MPa and 0.51-1.36% and varied with lubricant used and time incubated in PBS. All control groups exhibited significantly higher DTS (MPa) (groups 1-3: 53.17±1.78; 50.64±1.85; 45.17±1.77) and lower percentage weight change (groups 2-3: 0.51±0.03; 0.61±0.01) than specimens placed with an instrument lubricant, with significant differences between certain lubricant groups. Data from the present study suggest that the use of instrument lubricant may adversely effect the DTS and water uptake of composite restorative material. The use of instrument lubricants to aid composite placement is widespread however based on the data obtained it is suggested that discontinuing or limiting the use of instrument lubricants, and if necessary using the 'bonding agent' from a 3-step adhesive system is recommended as results suggest this has the least deleterious effect upon material properties.​. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. In vivo and in vitro assessment of an intraoral dental colorimeter.

    PubMed

    Karaagaclioglu, Lale; Terzioglu, Hakan; Yilmaz, Burak; Yurdukoru, Bengul

    2010-06-01

    The purpose of this study was to assess the performance of an intraoral dental colorimeter. In vivo repeatability of an intraoral colorimeter was assessed by performing color measurements of 30 individuals' right maxillary central incisor. Three consecutive measurements from each individual were made. In the in vitro part of the study, 25 metal-ceramic and 25 all-ceramic specimens were prepared. Five shades of metal-ceramic and all-ceramic specimens were selected for color determination. A widely recognized in vitro colorimeter was used as the control group for the in vitro performance assessment of the in vivo colorimeter. The color differentiation capability of two colorimeters was compared with the readings obtained from ceramic specimens. DeltaE values between shade groups of ceramic specimens were calculated and statistically analyzed with Student's t-test. The repeatability of the intraoral instrument was evaluated statistically with Intraclass correlation coefficient. The in vivo evaluation results showed that the overall repeatability coefficient values of L*, a*, and b* notations of the intraoral colorimeter were "excellent." The color differences (DeltaE) calculated between the colorimeters were significant only between shades A(1)-B(1) for metal-ceramic specimens (p= 0.002); however, from 5 of 10 shade couples of all-ceramic specimens, the color differences obtained from the readings of the in vivo colorimeter were significantly different from that of the in vitro colorimeter (p < 0.001). For all specimens, the differences between DeltaE values were within clinically acceptable limits (<3.5). Within the limitations of this study, the intraoral colorimeter exhibited successful in vivo repeatability; however, the color difference detection performance of the device varied depending on the translucency of the specimens.

  19. Characterization of Mechanical Properties of Nuclear Graphite Using Subsize Specimens and Reusing Tested Specimens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ji Hyun, Yoon; Byun, Thak Sang; Strizak, Joe P

    2011-01-01

    The mechanical properties of NBG-18 nuclear grade graphite have been characterized using small specimen test techniques and statistical treatment on the test results. New fracture strength and toughness test techniques were developed to use subsize cylindrical specimens with glued heads and to reuse their broken halves. Three sets of subsize cylindrical specimens with the different diameters of 4 mm, 8 mm, and 12 mm were tested to obtain tensile fracture strength. The longer piece of the broken halves was cracked from side surfaces and tested under three-point bend loading to obtain fracture toughness. Both the strength and fracture toughness datamore » were analyzed using Weibull distribution models focusing on size effect. The mean fracture strength decreased from 22.9 MPa to 21.5 MPa as the diameter increased from 4 mm to 12 mm, and the mean strength of 15.9 mm diameter standard specimen, 20.9 MPa, was on the extended trend line. These fracture strength data indicate that in the given diameter range the size effect is not significant and much smaller than that predicted by the Weibull statistics-based model. Further, no noticeable size effect existed in the fracture toughness data, whose mean values were in a narrow range of 1.21 1.26 MPa. The Weibull moduli measured for fracture strength and fracture toughness datasets were around 10. It is therefore believed that the small or negligible size effect enables to use the subsize specimens and that the new fracture toughness test method to reuse the broken specimens to help minimize irradiation space and radioactive waste.« less

  20. Design, analysis, and testing of a metal matrix composite web/flange intersection

    NASA Technical Reports Server (NTRS)

    Biggers, S. B.; Knight, N. F., Jr.; Moran, S. G.; Olliffe, R.

    1992-01-01

    An experimental and analytical program to study the local design details of a typical T-shaped web/flange intersection made from a metal matrix composite is described. Loads creating flange bending were applied to specimens having different designs and boundary conditions. Finite element analyses were conducted on models of the test specimens to predict the structural response. The analyses correctly predict failure load, mode, and location in the fillet material in the intersection region of the web and the flange when specimen quality is good. The test program shows the importance of fabrication quality in the intersection region. The full-scale test program that led to the investigation of this local detail is also described.

  1. Investigation of Weibull statistics in fracture analysis of cast aluminum

    NASA Technical Reports Server (NTRS)

    Holland, Frederic A., Jr.; Zaretsky, Erwin V.

    1989-01-01

    The fracture strengths of two large batches of A357-T6 cast aluminum coupon specimens were compared by using two-parameter Weibull analysis. The minimum number of these specimens necessary to find the fracture strength of the material was determined. The applicability of three-parameter Weibull analysis was also investigated. A design methodology based on the combination of elementary stress analysis and Weibull statistical analysis is advanced and applied to the design of a spherical pressure vessel shell. The results from this design methodology are compared with results from the applicable ASME pressure vessel code.

  2. Systematics and distribution of Cristaria plicata (Bivalvia, Unionidae) from the Russian Far East

    PubMed Central

    Klishko, Olga K.; Lopes-Lima, Manuel; Froufe, Elsa; Bogan, Arthur E.; Abakumova, Vera Y.

    2016-01-01

    Abstract The number of anodontine bivalve species placed in the genus Cristaria (Bivalvia, Unionidae) from the Russian Far East is still not stable among authors. Some recognize only one valid species Cristaria plicata (Leach, 1815) while others accept two additional species, Cristaria tuberculata Schumacher, 1817 and Cristaria herculea (Middendorff, 1847). In the present study, these taxonomic doubts are addressed using analyses of mitochondrial DNA sequences and shell morphometry. No significant differences have been revealed by the COI DNA sequences or the main statistical morphometric indices from the three Cristaria forms. In the specimens analysed, changes in shell morphometry with age suggest that original descriptions of the different forms may be attributed solely to differences in age and sex. We consider that Cristaria plicata, Cristaria tuberculata and Cristaria herculea from the Russian Far East should be considered as a single species, namely Cristaria plicata (Leach, 1815), with Cristaria tuberculata and Cristaria herculea as junior synonyms. The geographic range of Cristaria plicata and its conservation status are also presented here. PMID:27110206

  3. Thermoforming of glass fibre reinforced polypropylene: A study on the influence of different process parameters

    NASA Astrophysics Data System (ADS)

    Schug, Alexander; Winkelbauer, Jonas; Hinterhölzl, Roland; Drechsler, Klaus

    2017-10-01

    The aim of this study was to analyse the forming behaviour of glass fibre reinforced polypropylene and to identify the influence of several process parameters on the resulting part quality. For this purpose, a complex forming tool was designed, consisting of several areas with single and double curvature. The specimens were produced from unidirectional (UD) tape using the Fiberforge RELAY2000® automated tape laying machine and a subsequent consolidation step. They were then fixed in a support frame, pre-heated in an infrared oven, and formed in the forming tool, which was mounted into a hydraulic heating press. The investigated process parameters were the number and force of the springs in the support frame, the tool temperature and the forming pressure and speed. The layups of the specimens were [0/90/0/90/0¯]s and [0/45/90/-45/0¯]s. After the forming process, the parts were analysed in terms of their quality, with a special focus on wrinkles, undulations, gaps and surface roughness. In addition to optical analysis with a statistical evaluation of the results, 3D scans of the specimens at different steps of the forming process were made to gain an impression of the forming mechanisms and the development of failures. The ATOS system of GOM was used for these 3D scans. The results show that the undulations were influenced by the tool temperature and the spring force. By contrast, the surface quality was most strongly dependent on the forming pressure, which also influenced the size and the number of gaps. The forming speed affected the gaps as well. The tool temperature had the largest influence on the development of wrinkles. As expected, the quasi-isotropic layup showed distinctly more wrinkles and undulations, but it also presented a better surface quality than the orthotropic layup.

  4. The utility of captive animals in actualistic research: A geometric morphometric exploration of the tooth row of Alligator mississippiensis suggesting ecophenotypic influences and functional constraints.

    PubMed

    Drumheller, Stephanie K; Wilberg, Eric W; Sadleir, Rudyard W

    2016-07-01

    Captive broad snouted crocodylians are generally thought to have wider, shorter rostra than their wild counterparts. Interpreted to reflect morphological change in response to the conditions of captivity, this qualitative pattern could affect the utility of these animals in a variety of fields of research. However, due to relative ease of access and availability of life history data, captive animals are often utilized in actualistic research. Thus, this issue should be addressed in more detail. Here we explore snout shape variation between captive and wild members of Alligator mississippiensis using two-dimensional (2D) morphometric techniques. Several landmark schemesare used to assess the utility of different aspects of morphology in distinguishing the groups. While statistical analyses consistently differentiated between the groups, the area of morphospace occupied by wild members of A. mississippiensis generally overlapped with the larger area encompassing the captive specimens. This indicates that the captive condition is not as uniform as previously thought and instead encompasses a large spectrum of morphologies, ranging from the stereotypical broad, shortened snouts to outlines that are indistinguishable from the wild morphotype. These results align well with the interpretation that this change reflects an extreme example of ecophenotypy, since ranched, farmed, or zoo organisms are held in an array of enclosures, ranging from indoor, climate controlled pens to outdoor, more natural areas. This variation in environments should be reflected in different reactions to the animals' surroundings, resulting in a broad spectrum of morphotypes. While wild specimens are still preferred, especially for fine scale analyses, these results indicate that not all captive members of A. mississippiensis exhibit the extreme morphological alterations often cited in the literature. Weighing the conditions in which the animals are held and exploring the possibility of morphological differences against the benefits of using captive specimens should be part of any actualistic study. J. Morphol. 277:866-878, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  5. Laboratory-based performance evaluation of PIMA CD4+ T-lymphocyte count point-of-care by lay-counselors in Kenya.

    PubMed

    Zeh, Clement; Rose, Charles E; Inzaule, Seth; Desai, Mitesh A; Otieno, Fredrick; Humwa, Felix; Akoth, Benta; Omolo, Paul; Chen, Robert T; Kebede, Yenew; Samandari, Taraz

    2017-09-01

    CD4+ T-lymphocyte count testing at the point-of-care (POC) may improve linkage to care of persons diagnosed with HIV-1 infection, but the accuracy of POC devices when operated by lay-counselors in the era of task-shifting is unknown. We examined the accuracy of Alere's Pima™ POC device on both capillary and venous blood when performed by lay-counselors and laboratory technicians. In Phase I, we compared the perfomance of POC against FACSCalibur™ for 280 venous specimens by laboratory technicians. In Phase II we compared POC performance by lay-counselors versus laboratory technicians using 147 paired capillary and venous specimens, and compared these to FACSCalibur™. Statistical analyses included Bland-Altman analyses, concordance correlation coefficient, sensitivity, and specificity at treatment eligibility thresholds of 200, 350, and 500cells/μl. Phase I: POC sensitivity and specificity were 93.0% and 84.1% at 500cells/μl, respectively. Phase II: Good agreement was observed for venous POC results from both lay-counselors (concordance correlation coefficient (CCC)=0.873, bias -86.4cells/μl) and laboratory technicians (CCC=0.920, bias -65.7cells/μl). Capillary POC had good correlation: lay-counselors (CCC=0.902, bias -71.2cells/μl), laboratory technicians (CCC=0.918, bias -63.0cells/μl). Misclassification at the 500 cells/μl threshold for venous blood was 13.6% and 10.2% for lay-counselors and laboratory technicians and 12.2% for capillary blood in both groups. POC tended to under-classify the CD4 values with increasingly negative bias at higher CD4 values. Pima™ results were comparable to FACSCalibur™ for both venous and capillary specimens when operated by lay-counselors. POC CD4 testing has the potential to improve linkage to HIV care without burdening laboratory technicians in resource-limited settings. Published by Elsevier B.V.

  6. Coherent X-Ray Diffraction Imaging of Chloroplasts from Cyanidioschyzon merolae by Using X-Ray Free Electron Laser.

    PubMed

    Takayama, Yuki; Inui, Yayoi; Sekiguchi, Yuki; Kobayashi, Amane; Oroguchi, Tomotaka; Yamamoto, Masaki; Matsunaga, Sachihiro; Nakasako, Masayoshi

    2015-07-01

    Coherent X-ray diffraction imaging (CXDI) is a lens-less technique for visualizing the structures of non-crystalline particles with the dimensions of submicrometer to micrometer at a resolution of several tens of nanometers. We conducted cryogenic CXDI experiments at 66 K to visualize the internal structures of frozen-hydrated chloroplasts of Cyanidioschyzon merolae using X-ray free electron laser (XFEL) as a coherent X-ray source. Chloroplast dispersed specimen disks at a number density of 7/(10×10 µm(2)) were flash-cooled with liquid ethane without staining, sectioning or chemical labeling. Chloroplasts are destroyed at atomic level immediately after the diffraction by XFEL pulses. Thus, diffraction patterns with a good signal-to-noise ratio from single chloroplasts were selected from many diffraction patterns collected through scanning specimen disks to provide fresh specimens into the irradiation area. The electron density maps of single chloroplasts projected along the direction of the incident X-ray beam were reconstructed by using the iterative phase-retrieval method and multivariate analyses. The electron density map at a resolution of 70 nm appeared as a C-shape. In addition, the fluorescence image of proteins stained with Flamingo™ dye also appeared as a C-shape as did the autofluorescence from Chl. The similar images suggest that the thylakoid membranes with an abundance of proteins distribute along the outer membranes of chloroplasts. To confirm the present results statistically, a number of projection structures must be accumulated through high-throughput data collection in the near future. Based on the results, we discuss the feasibility of XFEL-CXDI experiments in the structural analyses of cellular organelles. © The Author 2015. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  7. Evaluation of a 6% hydrogen peroxide tooth-whitening gel on enamel microhardness after extended use.

    PubMed

    Toteda, Mariarosaria; Philpotts, Carole J; Cox, Trevor F; Joiner, Andrew

    2008-11-01

    To evaluate the effects of a 6% hydrogen peroxide tooth whitener, Xtra White, on sound human enamel microhardness in vitro after an extended and exaggerated simulated 8 weeks of product use. Polished human enamel specimens were prepared and baseline microhardness and color measurements determined. The enamel specimens were exposed to a fluoride-containing toothpaste for 30 seconds and then exposed to water, Xtra White, a control carbopol gel containing no hydrogen peroxide, or a carbonated beverage (each group, n = 8) for 20 minutes. Specimens were exposed to whole saliva at all other times. In order to simulate 8 weeks of extended product use, quadruple the length of the manufacturer's instructions, 112 treatments, were conducted. Microhardness measurements were taken after 2, 4, 6, and 8 weeks of simulated treatments, and color was measured after 2 and 8 weeks. The Xtra White-treated specimens showed a statistically significant (P < .0001) increase in L* and decrease in b* compared to the water-treated specimens after 2 weeks simulated use, indicating bleaching had occurred. The carbonated beverage-treated specimens were significantly softened (P = .0009) compared to baseline after only 1 treatment. The carbopol gel-treated specimens were significantly softened (P = .0028) after 2 weeks of simulated treatments compared to baseline. There were no statistically significant differences in enamel microhardness between baseline and all treatment times for XW and water groups. Xtra White does not have any deleterious effects on sound human enamel microhardness after an extended and exaggerated simulated 8 weeks of product use.

  8. Preliminary buprenorphine sublingual tablet pharmacokinetic data in plasma, oral fluid and sweat during treatment of opioid-dependent pregnant women

    PubMed Central

    Concheiro, Marta; Jones, Hendreé E.; Johnson, Rolley E.; Choo, Robin; Huestis, Marilyn A.

    2011-01-01

    Background Buprenorphine is currently under investigation as a pharmacotherapy to treat pregnant women for opioid dependence. This research evaluates buprenorphine (BUP), norbuprenophine (NBUP), buprenorphine-glucuronide (BUP-Gluc) and norbuprenorphine-glucuronide (NBUP-Gluc) pharmacokinetics after high dose (14–20 mg) BUP sublingual tablet administration in three opioid-dependent pregnant women. Methods Oral fluid and sweat specimens were collected in addition to plasma specimens for 24 h during gestation weeks 28 or 29 and 34, and 2 months after delivery. Tmax was not affected by pregnancy; however, BUP and NBUP Cmax and AUC0–24h tended to be lower during pregnancy compared to postpartum levels. Results Statistically significant but weak positive correlations were found for BUP plasma and OF concentrations, and BUP/NBUP ratios in plasma and OF. Conclusion Statistically significant negative correlations were observed for times of specimen collection and BUP and NBUP OF/plasma ratios. BUP-Gluc and NBUP-Gluc were detected in only 5% of OF specimens. In sweat, BUP and NBUP were detected in only 4 of 25 (12 or 24 h) specimens in low concentrations (<2.4 ng/patch). These preliminary data describe BUP and metabolite pharmacokinetics in pregnant women and suggest that, like methadone, upward dose adjustments may be needed with advancing gestation. PMID:21860340

  9. Fascin expression in cholesteatoma: correlation with destruction of the ossicular chain and extent of disease.

    PubMed

    Binnetoglu, A; Sari, M; Baglam, T; Erbarut Seven, I; Yumusakhuylu, A C; Topuz, M F; Batman, C

    2015-08-01

    Fascin is an actin-bundling protein found in cell membrane protrusions and increases cell motility. The expression of fascin in epithelial neoplasms has been described only recently. No data are available concerning the role of this protein in invasive cholesteatoma. Thus, we investigated the expression of fascin in cholesteatoma tissue and the relationship between fascin expression and intraoperative evaluation of the destruction of the ossicular chain and extent of disease. Cholesteatoma specimens of 28 patients and external auditory canal (EAC) skin specimens of the same patients (as the control group) were collected from mastoidectomies. Immunohistochemical technique was used to investigate the fascin expression in all cholesteatoma tissues and EAC skin specimens. Immunohistochemical staining was assessed semiquantitatively based on the thickness of epithelium. SPSS software version 16.0 (SPSS Inc., Chicago, IL, USA) was performed to statistically analyse the relationships between fascin expression and intraoperative evaluation destruction of ossicular chain and extent of the disease. Immunohistochemically, there was no or very low fascin expression observed in normal epithelial cells of EAC skin, while expressed in cholesteatoma tissue. Also, fascin expression in cholesteatoma tissues was significantly correlated with destruction of ossicular chain and extent of the disease. Fascin expression is usually found in cholesteatoma epithelium and is correlated with destruction of the ossicular chain and extent of disease. Considering all of the correlations between the clinical and histopathological findings, 'fascin immunoexpression scoring' may be used for histological grading of cholesteatoma. © 2015 John Wiley & Sons Ltd.

  10. Effect of monomer composition of polymer matrix on flexural properties of glass fibre-reinforced orthodontic archwire.

    PubMed

    Ohtonen, J; Vallittu, P K; Lassila, L V J

    2013-02-01

    To compare force levels obtained from glass fibre-reinforced composite (FRC) archwires. Specifically, FRC wires were compared with polymer matrices having different dimethacrylate monomer compositions. FRC material (E-glass provided by Stick Tech Ltd, Turku, Finland) with continuous unidirectional glass fibres and four different types of dimethacrylate monomer compositions for the resin matrix were tested. Cross-sectionally round FRC archwires fitting into the 0.3 mm slot of a bracket were divided into 16 groups with six specimens in each group. Glass fibres were impregnated by the manufacturer, and they were initially light-cured by hand light-curing unit or additionally post-cured in light-curing oven. The FRC archwire specimens were tested at 37°C according to a three-point bending test in dry and wet conditions using a span length of 10 mm and a crosshead speed of 1.0 mm/minute. The wires were loaded until final failure. The data were statistically analysed using analysis of variance (ANOVA). The dry FRC archwire specimens revealed higher load values than water stored ones, regardless of the polymer matrix. A majority of the FRC archwires showed higher load values after being post-cured. ANOVA revealed that the polymer matrix, curing method, and water storage had a significant effect (P < 0.05) on the flexural behaviour of the FRC archwire. Polymer matrix composition, curing method, and water storage affected the flexural properties and thus, force level and working range which could be obtained from the FRC archwire.

  11. A laboratory investigation of colour changes in two contemporary resin composites on exposure to spices.

    PubMed

    Yew, H Z; Berekally, T L; Richards, L C

    2013-12-01

    The aim of this study was to evaluate colour stability upon exposure to spices of a nano-filled and a micro-hybrid resin composite finished either with Sof-Lex™ discs (SLD) or against plastic strips (PS). Forty cylindrical specimens of 3 mm thickness were fabricated from Filtek Supreme XT ™ (FS) and Gradia Direct X™ (GD). The top surface of each specimen was polished with SLD while the bottom surface was finished against PS. All samples were immersed in staining solutions (0.1% weight turmeric, paprika and tamarind) and distilled water at 37 °C. Colour after 0, 24, 72 and 168 hours of immersion was recorded with a reflection spectrophotometer using CIE L*a*b* parameters and the results were statistically analysed with repeated measures of ANOVA and Bonferroni post hoc tests. Among all the staining solutions tested, the highest colour deviation was obtained in the turmeric group. FS finished against PS showed significantly more colour changes compared to specimens polished with SLD, while GD finished against PS were found to be more resistant to colour changes. Within the limitations of this study all the spices tested have the potential to stain resin composites with turmeric causing the most significant discolouration. Micro-hybrid and nano-filled resin composites appeared to respond differently to staining by spices when either finished with PS or polished with SLD. © 2013 Australian Dental Association.

  12. Erosive cola-based drinks affect the bonding to enamel surface: an in vitro study.

    PubMed

    Casas-Apayco, Leslie Caroll; Dreibi, Vanessa Manzini; Hipólito, Ana Carolina; Graeff, Márcia Sirlene Zardin; Rios, Daniela; Magalhães, Ana Carolina; Buzalaf, Marília Afonso Rabelo; Wang, Linda

    2014-01-01

    This study aimed to assess the impact of in vitro erosion provoked by different cola-based drinks (Coke types), associated or not with toothbrushing, to bonding to enamel. Fifty-six [Corrected] bovine enamel specimens were prepared and randomly assigned into seven groups (N=8): C- Control (neither eroded nor abraded), ERO-RC: 3x/1-minute immersion in Regular Coke (RC), ERO-LC: 3x/1-minute immersion in Light Coke (LC), ERO-ZC: 3x/1-minute immersion in Zero Coke (ZC) and three other eroded groups, subsequently abraded for 1-minute toothbrushing (EROAB-RC, EROAB-LC and EROAB-ZC, respectively). After challenges, they were stored overnight in artificial saliva for a total of 24 hours and restored with Adper Single Bond 2/Filtek Z350. Buildup coronal surfaces were cut in 1 mm2 -specimens and subjected to a microtensile test. Data were statistically analyzed by two-way ANOVA/Bonferroni tests (α=0.05). Failure modes were assessed by optical microscopy (X40). The Interface of the restorations were observed using Confocal Laser Scanning Microscopy (CLSM). All tested cola-based drinks significantly reduced the bond strength, which was also observed in the analyses of interfaces. Toothbrushing did not have any impact on the bond strength. CLSM showed that except for Zero Coke, all eroded specimens resulted in irregular hybrid layer formation. All cola-based drinks reduced the bond strength. Different patterns of hybrid layers were obtained revealing their impact, except for ZC.

  13. Analyses of changes on skin by aging.

    PubMed

    Kazanci, A; Kurus, M; Atasever, A

    2017-02-01

    This study aimed to evaluate the histological changes occurring in rat skin with increasing age, starting from the intrauterine period. Thirty-two healthy female Sprague-Dawley rats were evaluated in four groups: group 1 - intrauterine day 19, group 2 - postpartum day 21, group 3 - postpartum day 60, and group 4 - postpartum month 19. Skin samples from the back, abdomen, head, and upper and lower limbs were obtained from each subject under anesthesia. Tissue specimens were evaluated statistically and morphologically for the thicknesses of the epidermis, dermis, and basement membrane; the number, height, and width of dermal papillae; and the mast cell and pilosebaceous counts per group. The changes in collagen/elastic fibers and glycosaminoglycans were also assessed. Epidermal thickness was the highest in the intrauterine group; it decreased in the postpartum period and increased again in the aged group. Basal membrane thickness increased steadily with age. The number, height, and width of dermal papillae and dermal thickness increased up to day 60 after birth although these decreased in the aged group. Mast cell count also reached the maximum in the intrauterine group and gradually decreased with age. Pilosebaceous units of the dermis were fewer in intrauterine specimens; they showed an increase during the postpartum period and a decrease in the aged group. Skin specimens obtained from rats showed striking differences between the intrauterine and postpartum groups. Moreover, the postpartum group showed considerable intra-group differences. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. [Prolyl hydroxylase activity in liver specimens in chronic liver diseases (author's transl)].

    PubMed

    Langness, U; Clausnitzer, H; Verspohl, M; Grasedyck, K

    1978-08-25

    100 patients were laparoscopied, liver tissue specimens taken from atypically altered areas. Prolyl hydroxylase was determined in the specimen, in parallel tissue was examined by light microscope. 8 groups of patients could be differentiated: Patients 1. with active, 2, with inactive cirrhosis, 3. with fatty infiltrations, 4. with fatty infiltration and mesenchymal reaction, 5. with aggressive, 6. with persistent, 7. with reactive hepatitis, 8. patients without histological changes. In the case of connective tissue increase in the liver prolyl hydroxylase activities were statistically significant above normal. In addition, there was a statistically significant difference between the enzyme activities of each group. A correlation could be found between prolyl hydroxylase activity and morphologically estimated connective tissue formation, but not the serum enzyme activities usually determined in liver diseases. Therefore, could be concluded that prolyl hydroxylase activity is an index of actual collagen biosynthesis in chronic liver diseases.

  15. New method of determination of spot welding-adhesive joint fatigue life using full field strain evolution

    NASA Astrophysics Data System (ADS)

    Sadowski, T.; Kneć, M.

    2016-04-01

    Fatigue tests were conducted since more than two hundred years ago. Despite this long period, as fatigue phenomena are very complex, assessment of fatigue response of standard materials or composites still requires a long time. Quite precise way to estimate fatigue parameters is to test at least 30 standardized specimens for the analysed material and further statistical post processing is required. In case of structural elements analysis like hybrid joints (Figure 1), the situation is much more complex as more factors influence the fatigue load capacity due to much more complicated structure of the joint in comparison to standard materials specimen, i.e. occurrence of: welded hot spots or rivets, adhesive layers, local notches creating the stress concentrations, etc. In order to shorten testing time some rapid methods are known: Locati's method [1] - step by step load increments up to failure, Prot's method [2] - constant increase of the load amplitude up to failure; Lehr's method [2] - seeking for the point during regular fatigue loading when an increase of temperature or strains become non-linear. The present article proposes new method of the fatigue response assessment - combination of the Locati's and Lehr's method.

  16. HIV-1 and herpes simplex virus type-2 genital shedding among co-infected women using self-collected swabs in Chiang Rai, Thailand.

    PubMed

    Forhan, S E; Dunne, E F; Sternberg, M R; Whitehead, S J; Leelawiwat, W; Thepamnuay, S; Chen, C; Evans-Strickfaden, Tt; McNicholl, J M; Markowitz, L E

    2012-08-01

    We analysed 528 genital self-collected swabs (SCS) from 67 HIV-1 and herpes simplex virus type-2 (HSV-2) co-infected women collected during the placebo month of a randomized crossover clinical trial of suppressive acyclovir in Chiang Rai, Thailand. In this first longitudinal study of HIV-1 and HSV-2 co-infected women using genital SCS specimens, we found frequent mucosal HIV-1 shedding. Overall, 372 (70%) swabs had detectable HIV-1 RNA with median HIV-1 viral load of 2.61 log(10) copies/swab. We found no statistically significant association between detectable HIV-1 RNA and HSV-2 DNA in the same SCS specimen (adjusted odds ratio [aOR] 1.40; 95% confidence intervals [CI], 0.78-2.60, P = 0.25). Only baseline HIV-1 plasma viral load was independently associated with genital HIV-1 RNA shedding (aOR, 7.6; 95% CI, 3.3-17.2, P < 0.0001). SCS may be useful for future HIV-1 and HSV-2 studies because this method allows for frequent genital sampling, and inclusion of genital sites other than the cervix.

  17. Influence of Bristle Stiffness of Manual Toothbrushes on Eroded and Sound Human Dentin – An In Vitro Study

    PubMed Central

    Arnold, Wolfgang H.; Domin, Julia

    2016-01-01

    Aim The aim of this study was to determine the influence of manual toothbrushes with different bristle stiffness on the abrasivity on eroded and sound human dentin. Materials and Methods Dentin specimens were made from impacted third molars and attributed to three groups: erosion-abrasion (EA), abrasion (A) and erosion (E). The specimens from EA and E were treated with 1% citric acid (pH 2.3) for 1 min rinsed, and neutralized with artificial saliva for 15 min. This cycle was repeated five times. Thereafter, specimens from EA and A were treated with three toothbrushes types with different bristle stiffness (soft, medium, and hard) in a custom-made toothbrushing machine. The brushing was performed at a load of 3 N with a toothpaste slurry for 630 s. This procedure was repeated five times, in group EA after each erosion cycle. EA and A groups passed through five cycles with a total of 6300 strokes. The abrasivity was analyzed by contact-free profilometry. Kruskal-Wallis and Mann-Whitney U tests were performed for statistical analysis. Results With respect to bristle stiffness there was no statistically significant difference in dentin loss within the EA group. In group A, a statistically significantly higher dentin loss was found for the soft in comparison to the hard bristles. No statistically significant differences were measured between soft/medium and medium/hard toothbrushes. The amount of dentin loss from specimens in the EA group was significantly higher than in the A group. Conclusions Within the limitations of this study, the dentin loss in the Abrasion group was higher with soft bristles than with hard ones. This result might have an influence on the toothbrush recommendations for patients with non-carious cervical lesions. PMID:27070901

  18. Flexural strength and reliability of monolithic and trilayer ceramic structures obtained by the CAD-on technique.

    PubMed

    Basso, G R; Moraes, R R; Borba, M; Griggs, J A; Della Bona, A

    2015-12-01

    To evaluate the flexural strength, Weibull modulus, fracture toughness, and failure behavior of ceramic structures obtained by the CAD-on technique, testing the null hypothesis that trilayer structures show similar properties to monolithic structures. Bar-shaped (1.8mm×4mm×16mm) monolithic specimens of zirconia (IPS e.max ZirCAD - Ivoclar Vivadent) and trilayer specimens of zirconia/fusion ceramic/lithium dissilicate (IPS e.max ZirCAD/IPS e.max CAD Crystall./Connect/IPS e.max CAD, Ivoclar Vivadent) were fabricated (n=30). Specimens were tested in flexure in 37°C deionized water using a universal testing machine at a crosshead speed of 0.5mm/min. Failure loads were recorded, and the flexural strength values were calculated. Fractography principles were used to examine the fracture surfaces under optical and scanning electron microscopy. Data were statistically analyzed using Student's t-test and Weibull statistics (α=0.05). Monolithic and trilayer specimens showed similar mean flexural strengths, characteristic strengths, and Weibull moduli. Trilayer structures showed greater mean critical flaw and fracture toughness values than monolithic specimens (p<0.001). Most critical flaws in the trilayer groups were located on the Y-TZP surface subjected to tension and propagated catastrophically. Trilayer structures showed no flaw deflection at the interface. Considering the CAD-on technique, the trilayer structures showed greater fracture toughness than the monolithic zirconia specimens. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  19. Effectiveness of Specimen Collection Technology in the Reduction of Collection Turnaround Time and Mislabeled Specimens in Emergency, Medical-Surgical, Critical Care, and Maternal Child Health Departments.

    PubMed

    Saathoff, April M; MacDonald, Ryan; Krenzischek, Erundina

    2018-03-01

    The objective of this study was to evaluate the impact of specimen collection technology implementation featuring computerized provider order entry, positive patient identification, bedside specimen label printing, and barcode scanning on the reduction of mislabeled specimens and collection turnaround times in the emergency, medical-surgical, critical care, and maternal child health departments at a community teaching hospital. A quantitative analysis of a nonrandomized, pre-post intervention study design evaluated the statistical significance of reduction of mislabeled specimen percentages and collection turnaround times affected by the implementation of specimen collection technology. Mislabeled specimen percentages in all areas decreased from an average of 0.020% preimplementation to an average of 0.003% postimplementation, with a P < .001. Collection turnaround times longer than 60 minutes decreased after the implementation of specimen collection technology by an average of 27%, with a P < .001. Specimen collection and identification errors are a significant problem in healthcare, contributing to incorrect diagnoses, delayed care, lack of essential treatments, and patient injury or death. Collection errors can also contribute to an increased length of stay, increased healthcare costs, and decreased patient satisfaction. Specimen collection technology has structures in place to prevent collection errors and improve the overall efficiency of the specimen collection process.

  20. Effects of long duration exposure to simulated space environment on nonmetallic materials properties

    NASA Technical Reports Server (NTRS)

    Peacock, C. L., Jr.; Whitaker, A. F.

    1983-01-01

    Nonmetallic materials specimens from the Viking program were tested in situ invacuo after continuous thermal vacuum exposure from 1971/1972 to the present. Eleven tests were done on appropriate specimens of 30 materials; however, no single material received all the tests. Some specimens also were exposed to 1 or 2.5 MeV electrons at differing fluences before testing. Baseline exposure data is reported for graphite/epoxy specimens that were exposed to vacuum since 1974. These materials were transferred to the thermal vacuum storage facility for future in situ testing and irradiation. Thin G/E specimens were tensile tested after thermal-vacuum cycling exposure. Photomicrographic examinations and SEM analyses were done on the failed specimens.

  1. Nonlinear fracture of concrete and ceramics

    NASA Technical Reports Server (NTRS)

    Kobayashi, Albert S.; Du, Jia-Ji; Hawkins, Niel M.; Bradt, Richard C.

    1989-01-01

    The nonlinear fracture process zones in an impacted unnotched concrete bend specimen, a prenotched ceramic bend specimen, and an unnotched ceramic/ceramic composite bend specimen were estimated through hybrid experimental numerical analysis. Aggregate bridging in concrete, particulate bridging in ceramics, and fiber bridging in ceramic/ceramic composite are modeled by Barenblatt-type cohesive zones which are incorporated into the finite-element models of the bend specimens. Both generation and propagation analyses are used to estimate the distribution of crack closure stresses in the nonlinear fracture process zones. The finite-element models are then used to simulate fracture tests consisting of rapid crack propagation in an impacted concrete bend specimen, and stable crack growth and strain softening in a ceramic and ceramic/ceramic composite bend specimens.

  2. Replacement/Refurbishment of JSC/NASA POD Specimens

    NASA Technical Reports Server (NTRS)

    Castner, Willard L.

    2010-01-01

    The NASA Special NDE certification process requires demonstration of NDE capability by test per NASA-STD-5009. This test is performed with fatigue cracked specimens containing very small cracks. The certification test results are usually based on binomial statistics and must meet a 90/95 Probability of Detection (POD). The assumption is that fatigue cracks are tightly closed, difficult to detect, and inspectors and processes passing such a test are well qualified for inspecting NASA fracture critical hardware. The JSC NDE laboratory has what may be the largest inventory that exists of such fatigue cracked NDE demonstration specimens. These specimens were produced by the hundreds in the late 1980s and early 1990s. None have been produced since that time and the condition and usability of the specimens are questionable.

  3. Potential of nano-silver fluoride for tooth enamel caries prevention

    NASA Astrophysics Data System (ADS)

    Silva, Amitis V. C.; Mota, Cláudia C. B. O.; Teixeira, Joás. A.; Lins, Emery C.; Gomes, Anderson S. L.; Rosenblatt, Aronita

    2018-02-01

    This ex vivo study evaluated the efficiency of nano-silver fluoride (NSF) to enamel remineralization of deciduous teeth submitted to a high cariogenic challenge. 33 specimens of sound enamel were distributed into three groups: treated with sodium fluoride, with NSF, and deionized water. All specimens were submitted to microhardness test before chemical caries induction; post-induction of caries; and post-cariogenic challenge. The high cariogenic challenge was carried out in 14 daily cycles. There was no significant statistical difference (p=0.958) of enamel microhardness between NSFtreated and NaF-treated specimens. However, it presented significant difference between water-treated specimens and both NSF-treated and NaF-treated specimens (p=0.003).Furthermore, optical coherence tomography was employed for caries diagnosis, as it can be used in clinical environment.

  4. Elastic-plastic finite-element analyses of thermally cycled double-edge wedge specimens

    NASA Technical Reports Server (NTRS)

    Kaufman, A.; Hunt, L. E.

    1982-01-01

    Elastic-plastic stress-strain analyses were performed for double-edge wedge specimens subjected to thermal cycling in fluidized beds at 316 and 1088 C. Four cases involving different nickel-base alloys (IN 100, Mar M-200, NASA TAZ-8A, and Rene 80) were analyzed by using the MARC nonlinear, finite element computer program. Elastic solutions from MARC showed good agreement with previously reported solutions obtained by using the NASTRAN and ISO3DQ computer programs. Equivalent total strain ranges at the critical locations calculated by elastic analyses agreed within 3 percent with those calculated from elastic-plastic analyses. The elastic analyses always resulted in compressive mean stresses at the critical locations. However, elastic-plastic analyses showed tensile mean stresses for two of the four alloys and an increase in the compressive mean stress for the highest plastic strain case.

  5. TEM and XAS investigation of fission gas behaviors in U-Mo alloy fuels through ion beam irradiation

    NASA Astrophysics Data System (ADS)

    Zang, Hang; Yun, Di; Mo, Kun; Wang, Kunpeng; Mohamed, Walid; Kirk, Marquis A.; Velázquez, Daniel; Seibert, Rachel; Logan, Kevin; Terry, Jeffrey; Baldo, Peter; Yacout, Abdellatif M.; Liu, Wenbo; Zhang, Bo; Gao, Yedong; Du, Yang; Liu, Jing

    2017-10-01

    In this study, smaller-grained (hundred nano-meter size grain) and larger-grained (micro-meter size grain) U-10Mo specimens have been irradiated (implanted) with 250 keV Xe+ beam and were in situ characterized by TEM. Xe bubbles were not seen in the specimen after an implantation fluence of 2 × 1020 ions/m2 at room temperature. Nucleation of Xe bubbles happened during heating of the specimen to a final temperature of 300 °C. By comparing measured Xe bubble statistics, the nucleation and growth behaviors of Xe bubbles were investigated in smaller-grained and larger-grained U-10Mo specimens. A multi-atom kind of nucleation mechanism has been observed in both specimens. X-ray Absorption spectroscopy showed the edge position in the bubbles to be the same as that of Xe gas. The size of Xe bubbles has been shown to be bigger in larger-grained specimens than in smaller-grained specimens at the same implantation conditions.

  6. Small non-coding RNA profiling in human biofluids and surrogate tissues from healthy individuals: description of the diverse and most represented species.

    PubMed

    Ferrero, Giulio; Cordero, Francesca; Tarallo, Sonia; Arigoni, Maddalena; Riccardo, Federica; Gallo, Gaetano; Ronco, Guglielmo; Allasia, Marco; Kulkarni, Neha; Matullo, Giuseppe; Vineis, Paolo; Calogero, Raffaele A; Pardini, Barbara; Naccarati, Alessio

    2018-01-09

    The role of non-coding RNAs in different biological processes and diseases is continuously expanding. Next-generation sequencing together with the parallel improvement of bioinformatics analyses allows the accurate detection and quantification of an increasing number of RNA species. With the aim of exploring new potential biomarkers for disease classification, a clear overview of the expression levels of common/unique small RNA species among different biospecimens is necessary. However, except for miRNAs in plasma, there are no substantial indications about the pattern of expression of various small RNAs in multiple specimens among healthy humans. By analysing small RNA-sequencing data from 243 samples, we have identified and compared the most abundantly and uniformly expressed miRNAs and non-miRNA species of comparable size with the library preparation in four different specimens (plasma exosomes, stool, urine, and cervical scrapes). Eleven miRNAs were commonly detected among all different specimens while 231 miRNAs were globally unique across them. Classification analysis using these miRNAs provided an accuracy of 99.6% to recognize the sample types. piRNAs and tRNAs were the most represented non-miRNA small RNAs detected in all specimen types that were analysed, particularly in urine samples. With the present data, the most uniformly expressed small RNAs in each sample type were also identified. A signature of small RNAs for each specimen could represent a reference gene set in validation studies by RT-qPCR. Overall, the data reported hereby provide an insight of the constitution of the human miRNome and of other small non-coding RNAs in various specimens of healthy individuals.

  7. Probability of brittle failure

    NASA Technical Reports Server (NTRS)

    Kim, A.; Bosnyak, C. P.; Chudnovsky, A.

    1991-01-01

    A methodology was developed for collecting statistically representative data for crack initiation and arrest from small number of test specimens. An epoxy (based on bisphenol A diglycidyl ether and polyglycol extended diglycyl ether and cured with diethylene triamine) is selected as a model material. A compact tension specimen with displacement controlled loading is used to observe multiple crack initiation and arrests. The energy release rate at crack initiation is significantly higher than that at a crack arrest, as has been observed elsewhere. The difference between these energy release rates is found to depend on specimen size (scale effect), and is quantitatively related to the fracture surface morphology. The scale effect, similar to that in statistical strength theory, is usually attributed to the statistics of defects which control the fracture process. Triangular shaped ripples (deltoids) are formed on the fracture surface during the slow subcritical crack growth, prior to the smooth mirror-like surface characteristic of fast cracks. The deltoids are complementary on the two crack faces which excludes any inelastic deformation from consideration. Presence of defects is also suggested by the observed scale effect. However, there are no defects at the deltoid apexes detectable down to the 0.1 micron level.

  8. In Vitro Wear Resistance of Nano-Hybrid Composite Denture Teeth.

    PubMed

    Munshi, Nabeel; Rosenblum, Marc; Jiang, Shuying; Flinton, Robert

    2017-04-01

    To evaluate the wear resistance of nano-hybrid composite denture teeth as compared to two commonly used denture teeth: interpenetrating polymer network (IPN) and double crosslinking polymethylmethacrylate (PMMA) denture teeth. 18 styli and 18 disk specimens were prepared from the three denture tooth materials: nano-hybrid composite, IPN, and double crosslinking PMMA. The specimens were mounted in a two-body wear testing machine to simulate chewing in the complete denture. The amount of wear from the styli specimens were measured before and after using a digital micrometer, and the depth of the wear track from the disk specimens was measured using a noncontact 3D optical profilometer. The total wear from each denture tooth group was compared using one-way ANOVA with a 0.05 significance level. A Tukey post hoc test was used to determine differences between the three groups. The mean total wear in the nano-hybrid composite teeth group was 1.16 mm, SD = 0.5 mm, statistically significantly higher (p ≤ 0.0001) than the IPN (mean = 0.13 mm, SD = 0.05) and double crosslinking PMMA tooth groups (mean = 0.31 mm, SD = 0.19). There was no statistically significant difference between IPN denture teeth and double crosslinking PMMA denture teeth in the amount of wear. Nano-hybrid composite denture teeth exhibited statistically significantly more wear than the IPN and double crosslinking PMMA denture teeth. © 2015 by the American College of Prosthodontists.

  9. Herbarium specimens can reveal impacts of climate change on plant phenology; a review of methods and applications.

    PubMed

    Jones, Casey A; Daehler, Curtis C

    2018-01-01

    Studies in plant phenology have provided some of the best evidence for large-scale responses to recent climate change. Over the last decade, more than thirty studies have used herbarium specimens to analyze changes in flowering phenology over time, although studies from tropical environments are thus far generally lacking. In this review, we summarize the approaches and applications used to date. Reproductive plant phenology has primarily been analyzed using two summary statistics, the mean flowering day of year and first-flowering day of year, but mean flowering day has proven to be a more robust statistic. Two types of regression models have been applied to test for associations between flowering, temperature and time: flowering day regressed on year and flowering day regressed on temperature. Most studies analyzed the effect of temperature by averaging temperatures from three months prior to the date of flowering. On average, published studies have used 55 herbarium specimens per species to characterize changes in phenology over time, but in many cases fewer specimens were used. Geospatial grid data are increasingly being used for determining average temperatures at herbarium specimen collection locations, allowing testing for finer scale correspondence between phenology and climate. Multiple studies have shown that inferences from herbarium specimen data are comparable to findings from systematically collected field observations. Understanding phenological responses to climate change is a crucial step towards recognizing implications for higher trophic levels and large-scale ecosystem processes. As herbaria are increasingly being digitized worldwide, more data are becoming available for future studies. As temperatures continue to rise globally, herbarium specimens are expected to become an increasingly important resource for analyzing plant responses to climate change.

  10. Design and fabrication of composite wing panels containing a production splice

    NASA Technical Reports Server (NTRS)

    Reed, D. L.

    1975-01-01

    Bolted specimens representative of both upper and lower wing surface splices of a transport aircraft were designed and manufactured for static and random load tension and compression fatigue testing including ground-air-ground load reversals. The specimens were fabricated with graphite-epoxy composite material. Multiple tests were conducted at various load levels and the results were used as input to a statistical wearout model. The statically designed specimens performed very well under highly magnified fatigue loadings. Two large panels, one tension and compression, were fabricated for testing by NASA-LRC.

  11. Apparatus description and data analysis of a radiometric technique for measurements of spectral and total normal emittance

    NASA Technical Reports Server (NTRS)

    Edwards, S. F.; Kantsios, A. G.; Voros, J. P.; Stewart, W. F.

    1975-01-01

    The development of a radiometric technique for determining the spectral and total normal emittance of materials heated to temperatures of 800, 1100, and 1300 K by direct comparison with National Bureau of Standards (NBS) reference specimens is discussed. Emittances are measured over the spectral range of 1 to 15 microns and are statistically compared with NBS reference specimens. Results are included for NBS reference specimens, Rene 41, alundum, zirconia, AISI type 321 stainless steel, nickel 201, and a space-shuttle reusable surface insulation.

  12. Method and apparatus for determining tensile strength

    DOEpatents

    Ratigan, J.L.

    1982-05-28

    A method and apparatus is described for determining the statistical distribution of apparent tensile strength of rock, the size effect with respect to tensile strength, as well as apparent deformation modulus of both intact and fractured or jointed rock. The method is carried out by inserting a plug of deformable material, such as rubber, in an opening of a specimen to be tested. The deformable material is loaded by an upper and lower platen until the specimen ruptures, whereafter the tensile strength is calculated based on the parameters of the test specimen and apparatus.

  13. Method and apparatus for determining tensile strength

    DOEpatents

    Ratigan, Joe L.

    1984-01-01

    A method and apparatus for determining the statistical distribution of apparent tensile strength of rock, the size effect with respect to tensile strength, as well as apparent deformation modulus of both intact and fractured or jointed rock. The method is carried out by inserting a plug of deformable material, such as rubber, in an opening of a specimen to be tested. The deformable material is loaded by an upper and lower platen until the specimen ruptures, whereafter the tensile strength is calculated based on the parameters of the test specimen and apparatus.

  14. Scanning transmission ion micro-tomography (STIM-T) of biological specimens.

    PubMed

    Schwertner, Micheal; Sakellariou, Arthur; Reinert, Tilo; Butz, Tilman

    2006-05-01

    Computed tomography (CT) was applied to sets of Scanning Transmission Ion Microscopy (STIM) projections recorded at the LIPSION ion beam laboratory (Leipzig) in order to visualize the 3D-mass distribution in several specimens. Examples for a test structure (copper grid) and for biological specimens (cartilage cells, cygospore) are shown. Scanning Transmission Micro-Tomography (STIM-T) at a resolution of 260 nm was demonstrated for the first time. Sub-micron features of the Cu-grid specimen were verified by scanning electron microscopy. The ion energy loss measured during a STIM-T experiment is related to the mass density of the specimen. Typically, biological specimens can be analysed without staining. Only shock freezing and freeze-drying is required to preserve the ultra-structure of the specimen. The radiation damage to the specimen during the experiment can be neglected. This is an advantage compared to other techniques like X-ray micro-tomography. At present, the spatial resolution is limited by beam position fluctuations and specimen vibrations.

  15. Brushing force of manual and sonic toothbrushes affects dental hard tissue abrasion.

    PubMed

    Wiegand, Annette; Burkhard, John Patrik Matthias; Eggmann, Florin; Attin, Thomas

    2013-04-01

    This study aimed to determine the brushing forces applied during in vivo toothbrushing with manual and sonic toothbrushes and to analyse the effect of these brushing forces on abrasion of sound and eroded enamel and dentin in vitro. Brushing forces of a manual and two sonic toothbrushes (low and high frequency mode) were measured in 27 adults before and after instruction of the respective brushing technique and statistically analysed by repeated measures analysis of variance (ANOVA). In the in vitro experiment, sound and eroded enamel and dentin specimens (each subgroup n = 12) were brushed in an automatic brushing machine with the respective brushing forces using a fluoridated toothpaste slurry. Abrasion was determined by profilometry and statistically analysed by one-way ANOVA. Average brushing force of the manual toothbrush (1.6 ± 0.3 N) was significantly higher than for the sonic toothbrushes (0.9 ± 0.2 N), which were not significantly different from each other. Brushing force prior and after instruction of the brushing technique was not significantly different. The manual toothbrush caused highest abrasion of sound and eroded dentin, but lowest on sound enamel. No significant differences were detected on eroded enamel. Brushing forces of manual and sonic toothbrushes are different and affect their abrasive capacity. Patients with severe tooth wear and exposed and/or eroded dentin surfaces should use sonic toothbrushes to reduce abrasion, while patients without tooth wear or with erosive lesions confining only to enamel do not benefit from sonic toothbrushes with regard to abrasion.

  16. High resolution trace element records from the deep sea hydrocoral Stylaster venustus: Implications for stylasterids as a paleoceanographic archive

    NASA Astrophysics Data System (ADS)

    Aranha, R. S.; Layne, G. D.; Edinger, E.; Piercey, G.

    2009-12-01

    Stylasterids are one of the lesser known groups of deep sea corals, but appear to have potential to serve as viable geochemical archives for reconstructing temperature, salinity and nutrient regimes in the deep ocean. This group of hydrocorals are present in most, if not all of the world’s major oceans. Stylasterid species dominantly have aragonitic skeletons, with a small percentage of species having calcitic skeletons (1). A recent study on the biomineralization of a deep sea stylasterid (Errina dabneyi) has revealed that during the organism’s growth, a steady dissolution and reprecipitation of skeletal material occurs in the central canals of the skeleton. This skeletal modification likely alters the stable isotope and/or trace element profiles of these corals, making them potentially less reliable as geochemical archives, depending on the scale of sampling (2). Recent specimens of Stylaster venustus were collected in July, 2008 from the Olympic Coast National Marine sanctuary off the coast of Washington at depths of 200 - 350 m. We used a Cameca IMS 4f Secondary Ion Mass Spectrometer (SIMS) to perform high spatial resolution (<25 µm) spot analyses of Sr/Ca, Mg/Ca and Na/Ca in detailed traverses across the basal cross-sections from three of these specimens. We identified the remineralized material by remnant porous texture and/or a substantially different trace element composition. Spot analyses corresponding to the remineralized material were eliminated from the dataset. In all three specimens we observed a pronounced inverse correlation (r = -0.36) of Mg/Ca and Sr/Ca profiles throughout the length of the transects . A positive correlation (r =0.46) between Na/Ca and Mg/Ca profiles was also noted in two of the specimens analyzed. These correlations strongly imply that the coral skeleton is recording either cyclical or episodic variations in temperature, with possible overprinting from other environmental variation. The exact relationship between the visible banding in the skeletal cross-section and any cyclicity of trace element profiles is currently ambiguous. However, our analyses demonstrate that microanalytical techniques are a viable means of extracting trace element records from these corals. Further statistical analysis of the trace element transects, in combination with a variety of imaging analyses of the same samples, should help us elucidate what portion of the geochemical signal is temperature dependent and what magnitude of temperature change is actually being recorded. Correlating these trace element profiles with instrumental temperature records will help confirm that useful geochemical archives are preserved by stylasterid skeletons. References: (1) Cairns SD and Macintyre IG. 1992. Phylogenetic implications of calcium carbonate mineralogy in the Stylasteridae (Cnidaria:Hydrozoa).Palaios 7: 96-107. (2) Wisshak M, López Correa M, Zibrowius H, Jakobsen J & Freiwald. (in press). Skeletal reorganisation affects geochemical signals, exemplified in the stylasterid hydrocoral Errina dabneyi (Azores Archipelago). Marine Ecology Progress Series.

  17. A Comparison of the Flexural and Impact Strengths and Flexural Modulus of CAD/CAM and Conventional Heat-Cured Polymethyl Methacrylate (PMMA).

    PubMed

    Al-Dwairi, Ziad N; Tahboub, Kawkab Y; Baba, Nadim Z; Goodacre, Charles J

    2018-06-13

    The introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) technology to the field of removable prosthodontics has recently made it possible to fabricate complete dentures of prepolymerized polymethyl methacrylate (PMMA) blocks, which are claimed to be of better mechanical properties; however, no published reports that have evaluated mechanical properties of CAD/CAM PMMA. The purpose of this study was to compare flexural strength, impact strength, and flexural modulus of two brands of CAD/CAM PMMA and a conventional heat-cured PMMA. 45 rectangular specimens (65 mm × 10 mm × 3 mm) were fabricated (15 CAD/CAM AvaDent PMMA specimens from AvaDent, 15 CAD/CAM Tizian PMMA specimens from Shütz Dental, 15 conventional Meliodent PMMA specimens from Heraeus Kulzer) and stored in distilled water at (37  ± 1°C) for 7 days. Specimens (N = 15) in each group were subjected to the three-point bending test and impact strength test, employing the Charpy configuration on unnotched specimens. The morphology of the fractured specimens was studied under a scanning electron microscope (SEM). Statistical analysis was performed using one-way ANOVA and Tukey pairwise multiple comparisons with 95% confidence interval. The Schütz Dental specimens showed the highest mean flexural strength (130.67 MPa) and impact strength (29.56 kg/m 2 ). The highest mean flexural modulus was recorded in the AvaDent group (2519.6 MPa). The conventional heat-cured group showed the lowest mean flexural strength (93.33 MPa), impact strength (14.756 kg/m 2 ), and flexural modulus (2117.2 MPa). Differences in means of flexural properties between AvaDent and Schütz Dental specimens were not statistically significant (p > 0.05). As CAD/CAM PMMA specimens exhibited improved flexural strength, flexural modulus, and impact strength in comparison to the conventional heat-cured groups, CAD/CAM dentures are expected to be more durable. Different brands of CAD/CAM PMMA may have inherent variations in mechanical properties. © 2018 by the American College of Prosthodontists.

  18. Reconsideration of Protocrea (Hypocreales, Hypocreaceae)

    USDA-ARS?s Scientific Manuscript database

    The genus Protocrea is re-defined, based on holotype and fresh specimens of its type species P. farinosa, using morphology of teleomorph and anamorph and phylogenetic analyses of rpb2 sequences. Data based on currently available specimens suggest the existence of six species. Apart from the type, P....

  19. Evaluating the irradiation effects on the elastic properties of miniature monolithic SiC tubular specimens

    NASA Astrophysics Data System (ADS)

    Singh, G.; Koyanagi, T.; Petrie, C.; Terrani, K.; Katoh, Y.

    2018-02-01

    The initial results of a post-irradiation examination study conducted on CVD SiC tubular specimens irradiated under a high radial heat flux are presented herein. The elastic moduli were found to decrease more than that estimated based on previous studies. The significant decreases in modulus are attributed to the cracks present in the specimens. The stresses in the specimens, calculated through finite element analyses, were found to be greater than the expected strength of irradiated specimens, indicating that the irradiation-induced stresses caused these cracks. The optical microscopy images and predicted stress distributions indicate that the cracks initiated at the inner surface and propagated outward.

  20. [Ultrasonographic evaluation of the uterine cervix length remaining after LOOP-excision].

    PubMed

    Robert, A-L; Nicolas, F; Lavoué, V; Henno, S; Mesbah, H; Porée, P; Levêque, J

    2014-04-01

    To assess whether there is a correlation between the length of a conization specimen and the length of the cervix measured by vaginal ultrasonography after the operation Prospective observational study including patients less than 45 years with measurement of cervical length before and the day of the conization, and measuring the histological length of the specimen. Among the 40 patients enrolled, the average ultrasound measurements before conization was 26.9 mm (± 4.9 mm) against 18.1mm (± 4.4mm) after conization with a mean difference of 8.8mm (± 2.4mm) (difference statistically significant P<.0001). The extent of histological specimen was 9 mm (± 2.2mm) on average. A correlation between ultrasound and histological measurements with a correlation coefficient R=0.85 was found statistically significant (P<0.0001). Moreover, the rate of cervix length remove by loop-excision in our series is 33% (± 8.5%). A good correlation between the measurements of the specimen and the cervical ultrasound length before and after conization was found, as a significant reduction in cervical length after conization. The precise length of the specimen should be known in case of pregnancy and the prevention of prematurity due to conization rests on selected indications and efficient surgical technique. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  1. Molecular Taxonomy of Anopheles (Nyssorhynchus) benarrochi (Diptera: Culicidae) and Malaria Epidemiology in Southern Amazonian Peru

    PubMed Central

    Conn, Jan E.; Moreno, Marta; Saavedra, Marlon; Bickersmith, Sara A.; Knoll, Elisabeth; Fernandez, Roberto; Vera, Hubert; Burrus, Roxanne G.; Lescano, Andres G.; Sanchez, Juan Francisco; Rivera, Esteban; Vinetz, Joseph M.

    2013-01-01

    Anopheline specimens were collected in 2011 by human landing catch, Shannon and CDC traps from the malaria endemic localities of Santa Rosa and San Pedro in Madre de Dios Department, Peru. Most specimens were either Anopheles (Nyssorhynchus) benarrochi B or An. (Nys.) rangeli, confirmed by polymerase chain reaction-restriction fragment length polymorphism-internal transcribed spacer 2 (PCR-RFLP-ITS2) and, for selected individuals, ITS2 sequences. A few specimens from Lupuna, Loreto Department, northern Amazonian Peru, were also identified as An. benarrochi B. A statistical parsimony network using ITS2 sequences confirmed that all Peruvian An. benarrochi B analyzed were identical to those in GenBank from Putumayo, southern Colombia. Sequences of the mtDNA COI BOLD region of specimens from all three Peruvian localities were connected using a statistical parsimony network, although there were multiple mutation steps between northern and southern Peruvian sequences. A Bayesian inference of concatenated Peruvian sequences of ITS2+COI detected a single clade with very high support for all An. benarrochi B except one individual from Lupuna that was excluded. No samples were positive for Plasmodium by CytB-PCR. PMID:23243107

  2. Impact of Nano Hydroxyapatite, Nano Silver Fluoride and Sodium Fluoride Varnish on Primary Teeth Enamel Remineralization: An In Vitro Study

    PubMed Central

    Nozari, Ali; Ajami, Shabnam; Rafiei, Azade

    2017-01-01

    Introduction Dental caries is still prevailing worldwide, although different anti caries products have been introduced. Each remineralizing agent has its own shortcomings. Therefore, looking for new agents to have benefits of previous ones with lesser side effects is worthwhile. Aim To determine the remineralization ability of NaF varnish, nano-Hydroxyapatite Serum (n-HAP) and Nano Silver Fluoride (NSF) on enamel of primary anterior teeth. Materials and Methods Incipient caries were induced in primary sound anterior teeth by storing each specimen in demineralization solution for 72 hours. Then they were randomly divided into four groups of 15 samples each: (1) NaF varnish; (2) n-HAP repairing serum; (3) NSF and (4) no treatment (control). Surface Microhardness (SMH) was assessed with Vickers micro hardness tester before and after demineralization and after 10 days of pH-cycling. A total of 12 random specimens from groups 1 to 4 (3 random samples of each group) were examined by Atomic Force Microscopy (AFM). The SMH values were analysed with one-way and repeated measures ANOVA. Level of significance was set at p=0.05. Results Post lesion SMH values significantly decreased in all groups (p<0.001). Post treatment SMH values significantly increased in comparison to post lesion ones (p<0.001) except for control group which was not different statistically (p=0.86). The highest SMH values were observed in NSF group (mean 222.90 ± 28.79). Statistically significant differences were shown between all groups (p<0.05). However, NaF varnish and n-HAP groups were not statistically different (p=0.165). AFM images demonstrated protective layers in all treated groups. Conclusion The results of this in vitro study suggest that NSF could have the greatest remineralization efficacy. NaF varnish and n-HAP serum were similar in remineralizing initial caries. Future clinical studies are recommended for selection of the most appropriate remineralizing agent in primary teeth. PMID:29207844

  3. A micro-computed tomographic study of band-shaped root canal isthmuses, having their floor in the apical third of mesial roots of mandibular first molars.

    PubMed

    Keleş, A; Keskin, C

    2018-02-01

    To conduct a quantitative and qualitative analysis of the band-shaped isthmus area, the floor of which was in the apical third in the mesial roots of mandibular first molars using micro-computed tomography (micro-CT). Micro-CT images of 269 mesial roots of mandibular first molars were evaluated, and 40 specimens with a band-shaped isthmus, with a floor in the apical third, were selected. The major diameter, minor diameter, roundness, area and perimeter values for the most coronal and apical slices where the isthmus was visible were measured. The distances between these slices were measured as the isthmus length, and the total volume, structure model index and surface area of the isthmus were measured. The distances between the isthmus floor and two apical foramina and the number of root canal orifices were calculated. The dimensions of the isthmus roof and the floor were compared, and the data were analysed using descriptive statistics and Student's t-tests with a significance threshold set at 5%. A total of 15% of the specimens had band-shaped isthmuses with a floor in the apical third. The isthmus roof exhibited significantly greater major and minor diameter values compared to the isthmus floor (P < 0.05). No significant difference was detected between the isthmus roof and the floor with regard to roundness (P > 0.05). Three- and two-dimensional analyses of the mesial roots of mandibular molars revealed that band-shaped isthmuses had complex shapes. © 2017 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  4. Macroscopic and microscopic effects of GaAIAs diode laser and dexamethasone therapies on oral mucositis induced by fluorouracil in rats.

    PubMed

    Lara, Renata Nemetala; da Guerra, Eliete Neves Silva; de Melo, Nilce Santos

    2007-01-01

    To present an animal model for mucositis induced by fluorouracil in rats, and test two therapeutic options, the GaAIAs laser and topical dexamethasone, analysing them with regard to the quality and quantity of tissue alterations and comparing them with the phases of mucositis. Forty-five Wistar rats (250 g) were treated with fluorouracil (60 mg/kg) and, in order to mimic the clinical effect of chronic irritation, the palatal mucosa was irritated by superficial scratching with an 18-gauge needle. When all of the rats presented oral ulcers of mucositis, they were randomly allocated to one of three groups: group I was treated with laser (GaAIAs), group II was treated with topical dexamethasone, and group III was not treated. Excisional biopsies of the palatal mucosa were then performed, and the rats were killed. Tissue sections were stained with haematoxylin and eosin for morphological analyses, and with toluidine blue for mast-cell counts. Group I specimens showed higher prevalence of ulcers, bacterial biofilm, necrosis and vascularisation, while group II specimens showed higher prevalance of granulation tissue formation. There were no significant statistical differences in the numbers of mast cells and epithelial thickness between groups. For the present model of mucositis, rats with palatal mucositis treated with laser (GaAIAs) showed characteristics compatible with the ulcerative phase of oral mucositis, and rats treated with topical dexamethasone showed characteristics compatible with the healing phase of mucositis. Topical dexamethasone was more efficient in the treatment of rats' oral mucositis than the laser.

  5. The fatigue life of a cobalt-chromium alloy after laser welding.

    PubMed

    Al-Bayaa, Nabil Jalal Ahmad; Clark, Robert K F; Juszczyk, Andrzej S; Radford, David R

    2011-03-01

    The aim of this study was to investigate the fatigue life of laser welded joints in a commercially available cast cobalt-chromium alloy. Twenty rod shaped specimens (40 mm x 1.5 mm) were cast and sand blasted. Ten specimens were used as controls and the remaining ten were sectioned and repaired using a pulsed Nd: YAG laser welder. All specimens were subjected to fatigue testing (30N - 2Hz) in a controlled environment. A statistically significant difference in median fatigue life was found between as-cast and laser welded specimens (p < 0.001). Consequently, the technique may not be appropriate for repairing cobalt chromium clasps on removable partial dentures. Scanning electron microscopy indicated the presence of cracks, pores and constriction of the outer surface in the welded specimens despite 70% penetration of the weld.

  6. Refining the 'cucumber' technique for laryngeal biopsy.

    PubMed

    Robertson, S; Cooper, L; McPhaden, A; MacKenzie, K

    2011-06-01

    To refine the case selection process for the 'cucumber' mounting system for laryngeal biopsies. We conducted a retrospective audit of cucumber technique specimens taken between January 2002 and December 2008. We analysed the clinical indications for biopsy and the pathological diagnosis, for each specimen, in order to inform our case selection process. The cucumber technique was used for 125 laryngeal specimens. 60 specimens were taken for diagnostic sampling, 46 were taken during endoscopic laser resection, and 19 for overtly benign pathology. The cucumber technique was most useful for the interpretation of margins in endoscopic laser resection specimens. The cucumber technique is most useful for endoscopic resection cases in which tumour, dysplasia or suspicious lesions have been excised. Detailed information on resection margins is invaluable during multidisciplinary team discussions on patient management. Detailed photography of mounted specimens enables both laryngologist and pathologist to orientate and interpret specimens accurately.

  7. Effect of repeated cycles of chemical disinfection on the roughness and hardness of hard reline acrylic resins.

    PubMed

    Pinto, Luciana de Rezende; Acosta, Emílio José T Rodríguez; Távora, Flora Freitas Fernandes; da Silva, Paulo Maurício Batista; Porto, Vinícius Carvalho

    2010-06-01

    The aim of this study was to assess the effect of repeated cycles of five chemical disinfectant solutions on the roughness and hardness of three hard chairside reliners. A total of 180 circular specimens (30 mm x 6 mm) were fabricated using three hard chairside reliners (Jet; n = 60, Kooliner; n = 60, Tokuyama Rebase II Fast; n = 60), which were immersed in deionised water (control), and five disinfectant solutions (1%, 2%, 5.25% sodium hypochlorite; 2% glutaraldehyde; 4% chlorhexidine gluconate). They were tested for Knoop hardness (KHN) and surface roughness (microm), before and after 30 simulated disinfecting cycles. Data was analysed by the factorial scheme (6 x 2), two-way analysis of variance (anova), followed by Tukey's test. For Jet (from 18.74 to 13.86 KHN), Kooliner (from 14.09 to 8.72 KHN), Tokuyama (from 12.57 to 8.28 KHN) a significant decrease in hardness was observed irrespective of the solution used on all materials. For Jet (from 0.09 to 0.11 microm) there was a statistically significant increase in roughness. Kooliner (from 0.36 to 0.26 microm) presented a statistically significant decrease in roughness and Tokuyama (from 0.15 to 0.11 microm) presented no statistically significant difference after 30 days. This study showed that all disinfectant solutions promoted a statistically significant decrease in hardness, whereas with roughness, the materials tested showed a statistically significant increase, except for Tokuyama. Although statistically significant values were registered, these results could not be considered clinically significant.

  8. Quality Assessments of Long-Term Quantitative Proteomic Analysis of Breast Cancer Xenograft Tissues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Jian-Ying; Chen, Lijun; Zhang, Bai

    The identification of protein biomarkers requires large-scale analysis of human specimens to achieve statistical significance. In this study, we evaluated the long-term reproducibility of an iTRAQ (isobaric tags for relative and absolute quantification) based quantitative proteomics strategy using one channel for universal normalization across all samples. A total of 307 liquid chromatography tandem mass spectrometric (LC-MS/MS) analyses were completed, generating 107 one-dimensional (1D) LC-MS/MS datasets and 8 offline two-dimensional (2D) LC-MS/MS datasets (25 fractions for each set) for human-in-mouse breast cancer xenograft tissues representative of basal and luminal subtypes. Such large-scale studies require the implementation of robust metrics to assessmore » the contributions of technical and biological variability in the qualitative and quantitative data. Accordingly, we developed a quantification confidence score based on the quality of each peptide-spectrum match (PSM) to remove quantification outliers from each analysis. After combining confidence score filtering and statistical analysis, reproducible protein identification and quantitative results were achieved from LC-MS/MS datasets collected over a 16 month period.« less

  9. Incidental non-benign gallbladder histopathology after cholecystectomy in an United Kingdom population: Need for routine histological analysis?

    PubMed Central

    Patel, Krashna; Dajani, Khaled; Iype, Satheesh; Chatzizacharias, Nikolaos A; Vickramarajah, Saranya; Singh, Prateush; Davies, Susan; Brais, Rebecca; Liau, Siong S; Harper, Simon; Jah, Asif; Praseedom, Raaj K; Huguet, Emmanuel L

    2016-01-01

    AIM To analyse the range of histopathology detected in the largest published United Kingdom series of cholecystectomy specimens and to evaluate the rational for selective histopathological analysis. METHODS Incidental gallbladder malignancy is rare in the United Kingdom with recent literature supporting selective histological assessment of gallbladders after routine cholecystectomy. All cholecystectomy gallbladder specimens examined by the histopathology department at our hospital during a five year period between March 2008 and March 2013 were retrospectively analysed. Further data was collected on all specimens demonstrating carcinoma, dysplasia and polypoid growths. RESULTS The study included 4027 patients. The majority (97%) of specimens exhibited gallstone or cholecystitis related disease. Polyps were demonstrated in 44 (1.09%), the majority of which were cholesterol based (41/44). Dysplasia, ranging from low to multifocal high-grade was demonstrated in 55 (1.37%). Incidental primary gallbladder adenocarcinoma was detected in 6 specimens (0.15%, 5 female and 1 male), and a single gallbladder revealed carcinoma in situ (0.02%). This large single centre study demonstrated a full range of gallbladder disease from cholecystectomy specimens, including more than 1% neoplastic histology and two cases of macroscopically occult gallbladder malignancies. CONCLUSION Routine histological evaluation of all elective and emergency cholecystectomies is justified in a United Kingdom population as selective analysis has potential to miss potentially curable life threatening pathology. PMID:27830040

  10. Development of requirements for environmental specimen banking in ecological monitoring (exemplified by the Chernobyl NPP accident area).

    PubMed

    Borzilov, V A

    1993-11-01

    Development of requirements for a data bank for natural media as a system of intercorrelated parameters to estimate system states are determined. The problems of functional agreement between experimental and calculation methods are analysed when organizing the ecological monitoring. The methods of forming the environmental specimen bank to estimate and forecast radioactive contamination and exposure dose are considered to be exemplified by the peculiarities of the spatial distribution of radioactive contamination in fields. Analysed is the temporal dynamics of contamination for atmospheric air, soil and water.

  11. Mechanical characterization and structural analysis of recycled fiber-reinforced-polymer resin-transfer-molded beams

    NASA Astrophysics Data System (ADS)

    Tan, Eugene Wie Loon

    1999-09-01

    The present investigation was focussed on the mechanical characterization and structural analysis of resin-transfer-molded beams containing recycled fiber-reinforced polymers. The beams were structurally reinforced with continuous unidirectional glass fibers. The reinforcing filler materials consisted entirely of recycled fiber-reinforced polymer wastes (trim and overspray). The principal resin was a 100-percent dicyclo-pentadiene unsaturated polyester specially formulated with very low viscosity for resin transfer molding. Variations of the resin transfer molding technique were employed to produce specimens for material characterization. The basic materials that constituted the structural beams, continuous-glass-fiber-reinforced, recycled-trim-filled and recycled-overspray-filled unsaturated polyesters, were fully characterized in axial and transverse compression and tension, and inplane and interlaminar shear, to ascertain their strengths, ultimate strains, elastic moduli and Poisson's ratios. Experimentally determined mechanical properties of the recycled-trim-filled and recycled-overspray-filled materials from the present investigation were superior to those of unsaturated polyester polymer concretes and Portland cement concretes. Mechanical testing and finite element analyses of flexure (1 x 1 x 20 in) and beam (2 x 4 x 40 in) specimens were conducted. These structurally-reinforced specimens were tested and analyzed in four-point, third-point flexure to determine their ultimate loads, maximum fiber stresses and mid-span deflections. The experimentally determined load capacities of these specimens were compared to those of equivalent steel-reinforced Portland cement concrete beams computed using reinforced concrete theory. Mechanics of materials beam theory was utilized to predict the ultimate loads and mid-span deflections of the flexure and beam specimens. However, these predictions proved to be severely inadequate. Finite element (fracture propagation) analyses of the flexure and beam specimens were also performed. These progressive failure analyses more closely approximated flexural behavior under actual testing conditions by reducing the elastic moduli of elements that were considered to have partially or totally failed. Individual element failures were predicted using the maximum stress, Tsai-Hill and Tsai-Wu failure criteria. Excellent predictions of flexural behavior were attributed to the progressive failure analyses combined with an appropriate failure criterion, and the reliable input material properties that were generated.

  12. Microtensile bond strength of different acrylic teeth to high-impact denture base resins.

    PubMed

    Colebeck, Amanda C; Monaco, Edward A; Pusateri, Christopher R; Davis, Elaine L

    2015-01-01

    This study evaluated the effect of denture base acrylic, denture tooth composition, and ridge-lap surface treatment on the microtensile bond strength (μTBS) of three commercially available denture teeth and two injection denture processing systems. Sixteen experimental groups were formed (n = 3), according to denture tooth surface treatment (no treatment or surface treatment recommended by the manufacturer), denture base processing technique and acrylic (SR-Ivocap-Ivocap Plus or Success-Lucitone 199), and tooth type-composition at bonding interface (BlueLine DCL-PMMA, Portrait IPN-PMMA, Phonares II-PMMA, Phonares II-NHC). Rectangular bar specimens with a 1 mm(2) cross sectional area were fabricated and subsequently thermocycled at 10,000 cycles between 5°C and 55°C with a 15-second dwell time. Select specimens underwent μTBS testing in a universal testing machine with a 1 kN load cell at 0.5 mm/min crosshead speed. Data were analyzed statistically by two and three-way ANOVA and Tukey post hoc test (α = 0.05). Mean μTBS ranged between 56.2 ± 5.6 and 60.8 ± 5.0 N/mm(2) for the Ivocap Plus specimens and 13.3 ± 5.12 to 60.1 ± 6.0 N/mm(2) for the Lucitone 199 specimens. Among the Ivocap specimens, BlueLine DCL and Phonares II NHC had significantly higher μTBS than Portrait IPN to Ivocap Plus acrylic. There were no statistically significant differences among Blueline, Phonares II PMMA, and Phonares II NHC, or between Phonares II PMMA and Portrait IPN. Within the Luctione 199 specimens, there was a significantly higher μTBS for BlueLine DCL and Phonares II NHC denture teeth with the manufacturer-recommended surface treatment when compared to control surface. BlueLine, Portrait, and Phonares II PMMA groups achieved significantly higher mean μTBS than the Phonares II NHC group. There were no statistically significant differences among BlueLine, Portrait, and Phonares II PMMA groups. When evaluating the μTBS of PMMA and NHC denture teeth to base resins, a stronger bond was achieved using materials produced by the same manufacturer. Within the Luctione 199 specimens, the Phonares II NHC group demonstrated significantly lower bond strength than other specimens, suggesting that gross ridge-lap reduction of NHC denture teeth is not recommended if a base acrylic by a different manufacturer from the tooth is going to be used. © 2014 American College of Prosthodontists.

  13. Biomechanical in vitro - stability testing on human specimens of a locking plate system against conventional screw fixation of a proximal first metatarsal lateral displacement osteotomy.

    PubMed

    Arnold, Heino; Stukenborg-Colsman, Christina; Hurschler, Christof; Seehaus, Frank; Bobrowitsch, Evgenij; Waizy, Hazibullah

    2012-01-01

    The aim of this study was to examine resistance to angulation and displacement of the internal fixation of a proximal first metatarsal lateral displacement osteotomy, using a locking plate system compared with a conventional crossed screw fixation. Seven anatomical human specimens were tested. Each specimen was tested with a locking screw plate as well as a crossed cancellous srew fixation. The statistical analysis was performed by the Friedman test. The level of significance was p = 0.05. We found larger stability about all three axes of movement analyzed for the PLATE than the crossed screws osteosynthesis (CSO). The Friedman test showed statistical significance at a level of p = 0.05 for all groups and both translational and rotational movements. The results of our study confirm that the fixation of the lateral proximal first metatarsal displacement osteotomy with a locking plate fixation is a technically simple procedure of superior stability.

  14. Biomechanical In Vitro - Stability Testing on Human Specimens of a Locking Plate System Against Conventional Screw Fixation of a Proximal First Metatarsal Lateral Displacement Osteotomy

    PubMed Central

    Arnold, Heino; Stukenborg-Colsman, Christina; Hurschler, Christof; Seehaus, Frank; Bobrowitsch, Evgenij; Waizy, Hazibullah

    2012-01-01

    Introduction: The aim of this study was to examine resistance to angulation and displacement of the internal fixation of a proximal first metatarsal lateral displacement osteotomy, using a locking plate system compared with a conventional crossed screw fixation. Materials and Methodology: Seven anatomical human specimens were tested. Each specimen was tested with a locking screw plate as well as a crossed cancellous srew fixation. The statistical analysis was performed by the Friedman test. The level of significance was p = 0.05. Results: We found larger stability about all three axes of movement analyzed for the PLATE than the crossed screws osteosynthesis (CSO). The Friedman test showed statistical significance at a level of p = 0.05 for all groups and both translational and rotational movements. Conclusion: The results of our study confirm that the fixation of the lateral proximal first metatarsal displacement osteotomy with a locking plate fixation is a technically simple procedure of superior stability. PMID:22675409

  15. Interlaboratory round robin study on axial tensile properties of SiC-SiC CMC tubular test specimens [Interlaboratory round robin study on axial tensile properties of SiC/SiC tubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Gyanender P.; Gonczy, Steve T.; Deck, Christian P.

    An interlaboratory round robin study was conducted on the tensile strength of SiC–SiC ceramic matrix composite (CMC) tubular test specimens at room temperature with the objective of expanding the database of mechanical properties of nuclear grade SiC–SiC and establishing the precision and bias statement for standard test method ASTM C1773. The mechanical properties statistics from the round robin study and the precision statistics and precision statement are presented herein. The data show reasonable consistency across the laboratories, indicating that the current C1773–13 ASTM standard is adequate for testing ceramic fiber reinforced ceramic matrix composite tubular test specimen. Furthermore, it wasmore » found that the distribution of ultimate tensile strength data was best described with a two–parameter Weibull distribution, while a lognormal distribution provided a good description of the distribution of proportional limit stress data.« less

  16. Evaluation of gram-chromotrope kinyoun staining technique: its effectiveness in detecting microsporidial spores in fecal specimens.

    PubMed

    Salleh, Fatmah M; Al-Mekhlafi, Abdulsalam M; Nordin, Anisah; Yasin, 'Azlin M; Al-Mekhlafi, Hesham M; Moktar, Norhayati

    2011-01-01

    This study was conducted to evaluate the modification of the usual Gram-chromotrope staining technique developed in-house known as Gram-chromotrope Kinyoun (GCK) in comparison with the Weber Modified Trichrome (WMT) staining technique; as the reference technique. Two hundred and ninety fecal specimens received by the Microbiology Diagnostic Laboratory of Hospital Universiti Kebangsaan Malaysia were examined for the presence of microsporidial spores. The sensitivity and specificity of GCK compared to the reference technique were 98% and 98.3%, respectively. The positive and negative predictive values were 92.5% and 99.6%, respectively. The agreement between the reference technique and the GCK staining technique was statistically significant by Kappa statistics (K = 0.941, P < 0.001). It is concluded that the GCK staining technique has high sensitivity and specificity in the detection of microsporidial spores in fecal specimens. Hence, it is recommended to be used in the diagnosis of intestinal microsporidiosis. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Interlaboratory round robin study on axial tensile properties of SiC-SiC CMC tubular test specimens [Interlaboratory round robin study on axial tensile properties of SiC/SiC tubes

    DOE PAGES

    Singh, Gyanender P.; Gonczy, Steve T.; Deck, Christian P.; ...

    2018-04-19

    An interlaboratory round robin study was conducted on the tensile strength of SiC–SiC ceramic matrix composite (CMC) tubular test specimens at room temperature with the objective of expanding the database of mechanical properties of nuclear grade SiC–SiC and establishing the precision and bias statement for standard test method ASTM C1773. The mechanical properties statistics from the round robin study and the precision statistics and precision statement are presented herein. The data show reasonable consistency across the laboratories, indicating that the current C1773–13 ASTM standard is adequate for testing ceramic fiber reinforced ceramic matrix composite tubular test specimen. Furthermore, it wasmore » found that the distribution of ultimate tensile strength data was best described with a two–parameter Weibull distribution, while a lognormal distribution provided a good description of the distribution of proportional limit stress data.« less

  18. Prediction and Verification of Ductile Crack Growth from Simulated Defects in Strength Overmatched Butt Welds

    NASA Technical Reports Server (NTRS)

    Nishioka, Owen S.

    1997-01-01

    Defects that develop in welds during the fabrication process are frequently manifested as embedded flaws from lack of fusion or lack of penetration. Fracture analyses of welded structures must be able to assess the effect of such defects on the structural integrity of weldments; however, the transferability of R-curves measured in laboratory specimens to defective structural welds has not been fully examined. In the current study, the fracture behavior of an overmatched butt weld containing a simulated buried, lack-of-penetration defect is studied. A specimen designed to simulate pressure vessel butt welds is considered; namely, a center crack panel specimen, of 1.25 inch by 1.25 inch cross section, loaded in tension. The stress-relieved double-V weld has a yield strength 50% higher than that of the plate material, and displays upper shelf fracture behavior at room temperature. Specimens are precracked, loaded monotonically while load-CMOD measurements are made, then stopped and heat tinted to mark the extent of ductile crack growth. These measurements are compared to predictions made using finite element analysis of the specimens using the fracture mechanics code Warp3D, which models void growth using the Gurson-Tvergaard dilitant plasticity formulation within fixed sized computational cells ahead of the crack front. Calibrating data for the finite element analyses, namely cell size and initial material porosities are obtained by matching computational predictions to experimental results from tests of welded compact tension specimens. The R-curves measured in compact tension specimens are compared to those obtained from multi-specimen weld tests, and conclusions as to the transferability of R-curves is discussed.

  19. Impact of Gastric Acid Induced Surface Changes on Mechanical Behavior and Optical Characteristics of Dental Ceramics.

    PubMed

    Kulkarni, Aditi; Rothrock, James; Thompson, Jeffery

    2018-01-14

    To test the impact of exposure to artificial gastric acid combined with toothbrush abrasion on the properties of dental ceramics. Earlier research has indicated that immersion in artificial gastric acid has caused increased surface roughness of dental ceramics; however, the combined effects of acid immersion and toothbrush abrasion and the impact of increased surface roughness on mechanical strength and optical properties have not been studied. Three commercially available ceramics were chosen for this study: feldspathic porcelain, lithium disilicate glass-ceramic, and monolithic zirconium oxide. The specimens (10 × 1 mm discs) were cut, thermally treated as required, and polished. Each material was divided into four groups (n = 8 per group): control (no exposure), acid only, brush only, acid + brush. The specimens were immersed in artificial gastric acid (50 ml of 0.2% [w/v] sodium chloride in 0.7% [v/v] hydrochloric acid mixed with 0.16 g of pepsin powder, pH = 2) for 2 minutes and rinsed with deionized water for 2 minutes. The procedure was repeated 6 times/day × 9 days, and specimens were stored in deionized water at 37°C. Toothbrush abrasion was performed using an ISO/ADA design brushing machine for 100 cycles/day × 9 days. The acid + brush group received both treatments. Specimens were examined under SEM and an optical microscope for morphological changes. Color and translucency were measured using spectrophotometer CIELAB coordinates (L*, a*, b*). Surface gloss was measured using a gloss meter. Surface roughness was measured using a stylus profilometer. Biaxial flexural strength was measured using a mechanical testing machine. The data were analyzed by one-way ANOVA followed by Tukey's HSD post hoc test (p < 0.05). Statistically significant changes were found for color, gloss, and surface roughness for porcelain and e.max specimens. No statistically significant changes were found for any properties of zirconia specimens. The acid treatment affected the surface roughness, color, and gloss of porcelain and e.max ceramics. The changes in translucency and mechanical strength for all materials were not statistically significant. Zirconia ceramic showed resistance to all treatments. © 2018 by the American College of Prosthodontists.

  20. Effect of chlorhexidine pretreatment on bond strength durability of caries-affected dentin over 2-year aging in artificial saliva and under simulated intrapulpal pressure.

    PubMed

    Mobarak, E H

    2011-01-01

    To evaluate the influence of 2% and 5% chlorhexidine (CHX) pretreatment on bond durability of a self-etching adhesive to normal (ND) and caries-affected (AD) dentin after 2-years of aging in artificial saliva and under simulated intrapulpal pressure (IPP). One hundred twenty freshly extracted carious teeth were ground to expose ND and AD. Specimens were distributed into three equal groups (n=40) according to whether the dentin substrates were pretreated with 2% or 5% CHX or with water (control). Clearfil SE Bond (Kuraray) was applied to both substrates and composite cylinders (0.9 mm diameter and 0.7 mm height) were formed. Pretreatment and bonding were done while the specimens were subjected to 15 mm Hg IPP. After curing, specimens were aged in artificial saliva at 37°C and under IPP at 20 mm Hg until being tested after 24 hours or 2 years (n=20/group). Microshear bond strength was evaluated. Failure modes were determined using a scanning electron microscope (SEM) at 400× magnification. Data were statistically analyzed using three-way analysis of variance (ANOVA); one-way ANOVA tests, and t-test (p<0.05). Additional specimens (n=5/group) were prepared to evaluate interfacial silver precipitation. For the 24-hour groups, there were no significant differences among the ND groups and AD groups. For ND aged specimens, the 5% CHX group had the highest value followed by the 2% CHX and control groups, although the difference was statistically insignificant. For AD aged specimens, the 5% CHX group revealed statistically higher bond values compared to the 2% CHX and control groups. Fracture modes were predominately adhesive and mixed. Different interfacial silver depositions were recorded. Two percent or 5% CHX pretreatment has no adverse effect on the 24-hour bonding to ND and AD. Five percent CHX was able to diminish the loss in bonding to AD after 2years of aging in artificial saliva and under simulated IPP.

  1. Molecular Phylogeny Demonstrates the Need for Taxonomic Reconsideration of Species Diversity of the Hydrocoral Genus Millepora (Cnidaria: Hydrozoa) in the Pacific.

    PubMed

    Takama, Okuto; Fernandez-Silva, Iria; López, Cataixa; Reimer, James Davis

    2018-04-01

    Millepora (Cnidaria: Hydrozoa: Milleporidae) spp. are distributed throughout shallow subtropical and tropical marine environments in the Indo-Pacific and Caribbean-Atlantic, and have traditionally been identified using pore characteristics and colony form. Until now, representatives of Millepora spp. on the island of Okinawa-jima, Japan, have been divided into five species; three branching species (Millepora intricata, M. tenera, M. dichotoma), one species with plate-like morphology (M. platyphylla), and one encrusting species (M. exaesa). There have been only a few reports from the Indo-Pacific that have studied the genetic diversity within Millepora spp., although phylogenetic analyses in the Caribbean-Atlantic have proven useful in delimiting closely-related species, while demonstrating that morphologically-based identification systems may have problems. In the present study, we sought to clarify taxonomic confusion of Millepora spp. in the Pacific by using sequence data of the ribosomal internal transcribed spacer (ITS-rDNA) of specimens from Okinawa, Japan and other localities (Johnston Atoll, Great Barrier Reef). Four separate clades were recovered from the ITS-rDNA analyses. Although we examined specimens of all three branching Millepora spp. previously reported from Okinawa-jima Island, in our phylogenetic analyses they were concentrated within a single clade, with only three specimens in other clades. Encrusting Millepora specimens were found within all clades, although it should be noted all species initially start as encrusting forms, and plate-like specimens were found within three clades. Our data also point to the existence of a previously unknown lineage within Millepora characterized by its ability to overgrow live scleractinian corals.

  2. NDE of PWA 1480 single crystal turbine blade material

    NASA Technical Reports Server (NTRS)

    Klima, Stanley J.; Orange, Thomas W.; Dreshfield, Robert L.

    1993-01-01

    Cantilever bending fatigue specimens were examined by fluorescent liquid penetrant and radioactive gas penetrant (Krypton) non-destructive evaluation (NDE) methods and tested. Specimens with cast, ground, or polished surface were evaluated to study the effect of surface condition on NDE and fatigue crack initiation. Fractographic and metallurgical analyses were performed to determine the nature of crack precursors. Preliminary results show that fatigue strength was lower for specimens with cast surfaces than for specimens with machined surfaces. The liquid penetrant and gas penetrant techniques both provided indications of a large population of defects on the cast surfaces. On ground or polished specimen surfaces, the gas penetrant appeared to estimate the actual number of voids more accurately than the liquid penetrant.

  3. Effect of mouthrinses with different active agents in the prevention of initial dental erosion.

    PubMed

    de Oliveira, Tatiane Alexandre; Scaramucci, Tais; Nogueira, Fernando Neves; Simões, Alyne; Sobral, Maria Angela Pita

    2015-01-01

    Hydrochloric acid (HCl) from the gastric juice is the only source of intrinsic acid, which can reach the oral cavity in cases of gastroesophageal reflux or chronic vomiting, enhancing the risk of dental erosion. Compare the effects of mouthrinses with different active agents in the prevention of initial dental erosion caused by HCl. Casein (CAS at 0.2%), sodium hexametaphosphate (HMP at 0.02%), titanium tetrafluoride (TiF4 at 0.34%), and stannous fluoride (SnF2 at 0.87%) were individually added to an experimental mouthrinse. The mouthrinse without additives was used as the negative control (C) and a commercially available mouthrinse for erosion (ELM-Elmex®) as the reference product. Enamel specimens were exposed to human saliva and randomly assigned to 6 experimental groups (n = 8). Specimens were submitted to erosion in HCl for 10 s, followed by to the experimental mouthrinses for 30 s, and artificial saliva for 60 min. This cycle was repeated 3 times. The total amounts of calcium and phosphorus released by the specimens in the 2nd and 3rd erosive challenges were evaluated by atomic emission spectrometry. Statistical analysis used Shapiro-Wilks and Hartley tests, followed by one-way ANOVA and Tukey tests. When compared with C, ELM and HMP presented significantly less calcium in solution, with no difference between them. All the groups showed similar and significantly less phosphorus than C, except CAS. HMP was the only agent that could match the protection against initial erosion of the commercially available mouthrinse in both analyses.

  4. The effect of MTAD, an endodontic irrigant, on fibroblast attachment to periodontally affected root surfaces: A SEM analysis.

    PubMed

    Ghandi, Mostafa; Houshmand, Behzad; Nekoofar, Mohammad H; Tabor, Rachel K; Yadeghari, Zahra; Dummer, Paul M H

    2013-03-01

    Root surface debridement (RSD) is necessary to create an environment suitable for reattachment of the periodontium. Root surface conditioning may aid the formation of a biocompatible surface suitable for cell reattachment. BioPure™ MTAD (mixture of Doxycycline, citric acid and a detergent) is an endodontic irrigant with antibacterial properties and the ability to remove smear layer. It was hypothesized that MTAD may be useful for root surface conditioning. The efficacy of MTAD as a conditioner was measured by examining fibroblast attachment to root surfaces. Thirty-two specimens of human teeth with advanced periodontal disease were used. The surfaces were root planed until smooth. Half of the specimens were treated with 0.9% saline and the other samples with Biopure MTAD. As a negative control group, five further samples were left unscaled with surface calculus. Human gingival fibroblast cells HGF1-PI1 were cultured and poured over the tooth specimens and incubated. After fixation, the samples were sputter-coated with gold and examined with a SEM. The morphology and number of attached, fixed viable cells were examined. The data was analysed using the Mann-Whitney-U statistical test. There was no significant difference between the numbers of attached cells in the experimental group treated with MTAD and the control group treated with saline. Little or no attached cells were seen in the negative control group. RSD created an environment suitable for cell growth and attachment in a laboratory setting. The use of MTAD did not promote the attachment and growth of cells on the surface of human roots following RSD.

  5. Erosive cola-based drinks affect the bonding to enamel surface: an in vitro study

    PubMed Central

    CASAS-APAYCO, Leslie Caroll; DREIBI, Vanessa Manzini; HIPÓLITO, Ana Carolina; GRAEFF, Márcia Sirlene Zardin; RIOS, Daniela; MAGALHÃES, Ana Carolina; BUZALAF, Marília Afonso Rabelo; WANG, Linda

    2014-01-01

    Objective This study aimed to assess the impact of in vitro erosion provoked by different cola-based drinks (Coke types), associated or not with toothbrushing, to bonding to enamel. Material and Methods Fifty-six bovine enamel specimens were prepared and randomly assigned into seven groups (N=8): C- Control (neither eroded nor abraded), ERO-RC: 3x/1-minute immersion in Regular Coke (RC), ERO-LC: 3x/1-minute immersion in Light Coke (LC), ERO-ZC: 3x/1-minute immersion in Zero Coke (ZC) and three other eroded groups, subsequently abraded for 1-minute toothbrushing (EROAB-RC, EROAB-LC and EROAB-ZC, respectively). After challenges, they were stored overnight in artificial saliva for a total of 24 hours and restored with Adper Single Bond 2/Filtek Z350. Buildup coronal surfaces were cut in 1 mm2 -specimens and subjected to a microtensile test. Data were statistically analyzed by two-way ANOVA/Bonferroni tests (α=0.05). Failure modes were assessed by optical microscopy (X40). The interface of the restorations were observed using Confocal Laser Scanning Microscopy (CLSM). Results All tested cola-based drinks significantly reduced the bond strength, which was also observed in the analyses of interfaces. Toothbrushing did not have any impact on the bond strength. CLSM showed that except for Zero Coke, all eroded specimens resulted in irregular hybrid layer formation. Conclusions All cola-based drinks reduced the bond strength. Different patterns of hybrid layers were obtained revealing their impact, except for ZC. PMID:24918663

  6. Reliability of scanning laser acoustic microscopy for detecting internal voids in structural ceramics

    NASA Technical Reports Server (NTRS)

    Roth, D. J.; Baaklini, G. Y.

    1986-01-01

    The reliability of 100 MHz scanning laser acoustic microscopy (SLAM) for detecting internal voids in sintered specimens of silicon nitride and silicon carbide was evaluated. The specimens contained artificially implanted voids and were positioned at depths ranging up to 2 mm below the specimen surface. Detection probability of 0.90 at a 0.95 confidence level was determined as a function of material, void diameter, and void depth. The statistical results presented for void detectability indicate some of the strengths and limitations of SLAM as a nondestructive evaluation technique for structural ceramics.

  7. Strength of a Ceramic Sectored Flexure Specimen

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wereszczak, Andrew A; Duffy, Stephen F; Baker, E. H.

    2008-01-01

    A new test specimen, defined here as the "sectored flexure strength specimen", was developed to measure the strength of ceramic tubes specifically for circumstances when flaws located at the tube's outer diameter are the strength-limiter and subjected to axial tension. The understanding of such strength-limitation is relevant for when ceramic tubes are subjected to bending or when the internal temperature is hotter than the tube's exterior (e.g., heat exchangers). The specimen is both economically and statistically attractive because eight specimens (eight in the case of this project - but the user is not necessarily limited to eight) were extracted outmore » of each length of tube. An analytic expression for maximum or failure stress, and relationships portraying effective area and effective volume as a function of Weibull modulus were developed. Lastly, it was proven from the testing of two ceramics that the sectored flexure specimen was very effective at producing failures caused by strength-limiting flaws located on the tube's original outer diameter. Keywords: ceramics, strength, sectored flexure specimen, effective area, effective volume, finite-element analysis, Weibull distribution, and fractography.« less

  8. Bonding resin thixotropy and viscosity influence on dentine bond strength.

    PubMed

    Niem, Thomas; Schmidt, Alexander; Wöstmann, Bernd

    2016-08-01

    To investigate the influence of bonding resin thixotropy and viscosity on dentine tubule penetration, blister formation and consequently on dentine bond strength as a function of air-blowing pressure (air-bp) intensity. Two HEMA-free, acetone-based, one-bottle self-etch adhesives with similar composition except disparate silica filler contents and different bonding resin viscosities were investigated. The high-filler-containing adhesive (G-Bond) featured a lower viscous bonding resin with inherent thixotropic resin (TR) properties compared to the low-filler-containing adhesive (iBond) exhibiting a higher viscous bonding resin with non-thixotropic resin (NTR) properties. Shear bond strength tests for each adhesive with low (1.5bar; 0.15MPa; n=16) and high (3.0bar; 0.30MPa; n=16) air-bp application were performed after specimen storage in distilled water (24h; 37.0±1.0°C). Results were analysed using a Student's t-test to identify statistically significant differences (p<0.05). Fracture surfaces of TR adhesive specimens were morphologically characterised by SEM. Statistically significant bond strength differences were obtained for the thixotropic resin adhesive (high-pressure: 24.6MPa, low-pressure: 9.6MPa). While high air-bp specimens provided SEM images revealing resin-plugged dentine tubules, resin tags and only marginally blister structures, low air-bp left copious droplets and open dentine tubules. In contrast, the non-thixotropic resin adhesive showed no significant bond strength differences (high-pressure: 9.3MPa, low-pressure: 7.6MPa). A pressure-dependent distinct influence of bonding resin thixotropy and viscosity on dentine bond strength has been demonstrated. Stronger adhesion with high air-bp application is explained by improved resin fluidity and facilitated resin penetration into dentine tubules. Filler particles used in adhesive systems may induce thixotropic effects in bonding resin layers, accounting for improved free-flowing resin properties. In combination with high air-bp this effect allows an easy plugging of dentine tubules and elimination of blister structures, both resulting in superior dentine bond strength. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Influence of laser structuring of PEEK, PEEK-GF30 and PEEK-CF30 surfaces on the shear bond strength to a resin cement.

    PubMed

    Henriques, Bruno; Fabris, Douglas; Mesquita-Guimarães, Joana; Sousa, Anne C; Hammes, Nathalia; Souza, Júlio C M; Silva, Filipe S; Fredel, Márcio C

    2018-08-01

    The aim of this study was to evaluate the influence of a surface conditioning technique using laser ablation and acid etching on PEEK substrate on its bonding strength to a resin cement. Cylindrical specimens of unfilled PEEK, 30% glass fiber reinforced PEEK and 30% carbon fiber reinforced PEEK were separated in four groups according to the following surface treatments: acid etching with H 2 SO 4 , laser ablation with 200 µm holes spaced 400 µm apart (D2E4), laser ablation with 200 µm holes spaced 600 µm apart (D2E6), and laser ablation (D2E4) followed by acid etching. A dual-curing resin cement (Allcem CORE) was then applied to the PEEK surface. Specimens were aged in distilled water at 37 °C for 24 h. Shear bond strength tests were performed to the fracture of the samples. Two-way ANOVA statistical analysis was performed with a significance level of 0.05. Scanning electron microscopy analysis was performed to analyse the conditioned and fracture surfaces. SEM images of the test interfaces showed that the resin cement could not flow in the holes designed by the laser ablation on the PEEK surface. The shear bond strength of PEEK to resin cement was not improved by the surface modification of the PEEK. Also, there was a statistically significant decrease in shear bond strength for unfilled PEEK specimens. On carbon or glass reinforced PEEK, the change was not significant. SEM images of the fracture surfaces revealed that the failure mode was mainly adhesive. Although laser ablation promoted the PEEK surface modification by the formation of retentive holes, the test resin cement could not thoroughly flow on the rough modified surfaces to establish an effective mechanical interlocking. That negatively affected the shear bonding strength of PEEK to the resin cement. Further studies should be carried out to increase the bonding between PEEK and resin cements. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. A comparative evaluation of efficacy of protaper universal rotary retreatment system for gutta-percha removal with or without a solvent.

    PubMed

    Kumar, M Sita Ram; Sajjan, Girija S; Satish, Kalyan; Varma, K Madhu

    2012-09-01

    The aim was to evaluate and compare the efficacy of ProTaper Universal rotary retreatment system with or without solvent and stainless steel hand files for endodontic filling removal from root canals and also to compare retreatment time for each system. Thirty extracted mandibular premolars with single straight canals were endodontically treated. Teeth were divided into three major groups, having 10 specimens each. Removal of obturating material in group 1 by stainless steel hand files with RC Solve, group 2 by ProTaper Universal retreatment instruments and group 3 by ProTaper Universal retreatment instruments along with RC solve was done. Retreatment was considered complete for all groups when no filling material was observed on the instruments. The retreatment time was recorded for each tooth. All specimens were grooved longitudinally in a buccolingual direction. The split halves were examined under a stereomicroscope and images were captured and analyzed. The remaining filling debris area ratios were considered for statistical analysis. With ANOVA test, statistical analysis showed that there was statistically no significant difference regarding the amount of filling remnants between the groups (P < 0.05). Differences between the means of groups are statistically significant regarding the retreatment time. Irrespective of the technique used, all the specimens had some remnants on the root canal wall. ProTaper Universal retreatment system files alone proved to be faster than the other experimental groups.

  11. Numerical 3D flow simulation of ultrasonic horns with attached cavitation structures and assessment of flow aggressiveness and cavitation erosion sensitive wall zones.

    PubMed

    Mottyll, Stephan; Skoda, Romuald

    2016-07-01

    As a contribution to a better understanding of cavitation erosion mechanisms, a compressible inviscid finite volume flow solver with barotropic homogeneous liquid-vapor mixture cavitation model is applied to ultrasonic horn set-ups with and without stationary specimen, that exhibit attached cavitation at the horn tip. Void collapses and shock waves, which are closely related to cavitation erosion, are resolved. The computational results are compared to hydrophone, shadowgraphy and erosion test data. At the horn tip, vapor volume and topology, subharmonic oscillation frequency as well as the amplitude of propagating pressure waves are in good agreement with experimental data. For the evaluation of flow aggressiveness and the assessment of erosion sensitive wall zones, statistical analyses of wall loads and of the multiplicity of distinct collapses in wall-adjacent flow regions are applied to the horn tip and the stationary specimen. An a posteriori projection of load collectives, i.e. cumulative collapse rate vs. collapse pressure, onto a reference grid eliminates the grid dependency effectively for attached cavitation at the horn tip, whereas a significant grid dependency remains at the stationary specimen. The load collectives show an exponential decrease towards higher collapse pressures. Erosion sensitive wall zones are well predicted for both, horn tip and stationary specimen, and load profiles are in good qualitative agreement with measured topography profiles of eroded duplex stainless steel samples after long-term runs. For the considered amplitude and gap width according to ASTM G32-10 standard, the analysis of load collectives reveals that the distinctive erosive ring shape at the horn tip can be attributed to frequent breakdown and re-development of a small portion of the tip-attached cavity. This partial breakdown of the attached cavity repeats at each driving cycle and is associated with relatively moderate collapse peak pressures, whereas the stationary specimen is rather unfrequently stressed at the end of each subharmonic oscillation cycle by the violent collapse of the complete cavity. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Different evolutionary pathways underlie the morphology of wrist bones in hominoids

    PubMed Central

    2013-01-01

    Background The hominoid wrist has been a focus of numerous morphological analyses that aim to better understand long-standing questions about the evolution of human and hominoid hand use. However, these same analyses also suggest various scenarios of complex and mosaic patterns of morphological evolution within the wrist and potentially multiple instances of homoplasy that would benefit from require formal analysis within a phylogenetic context. We identify morphological features that principally characterize primate – and, in particular, hominoid (apes, including humans) - wrist evolution and reveal the rate, process and evolutionary timing of patterns of morphological change on individual branches of the primate tree of life. Linear morphological variables of five wrist bones – the scaphoid, lunate, triquetrum, capitate and hamate – are analyzed in a diverse sample of extant hominoids (12 species, 332 specimens), Old World (8 species, 43 specimens) and New World (4 species, 26 specimens) monkeys, fossil Miocene apes (8 species, 20 specimens) and Plio-Pleistocene hominins (8 species, 18 specimens). Result Results reveal a combination of parallel and synapomorphic morphology within haplorrhines, and especially within hominoids, across individual wrist bones. Similar morphology of some wrist bones reflects locomotor behaviour shared between clades (scaphoid, triquetrum and capitate) while others (lunate and hamate) indicate clade-specific synapomorphic morphology. Overall, hominoids show increased variation in wrist bone morphology compared with other primate clades, supporting previous analyses, and demonstrate several occurrences of parallel evolution, particularly between orangutans and hylobatids, and among hominines (extant African apes, humans and fossil hominins). Conclusions Our analyses indicate that different evolutionary processes can underlie the evolution of a single anatomical unit (the wrist) to produce diversity in functional and morphological adaptations across individual wrist bones. These results exemplify a degree of evolutionary and functional independence across different wrist bones, the potential evolvability of skeletal morphology, and help to contextualize the postcranial mosaicism observed in the hominin fossil record. PMID:24148262

  13. Influence of artificial accelerated aging on dimensional stability of acrylic resins submitted to different storage protocols.

    PubMed

    Garcia, Lucas da Fonseca Roberti; Roselino, Lourenço de Moraes Rego; Mundim, Fabrício Mariano; Pires-de-Souza, Fernanda de Carvalho Panzeri; Consani, Simonides

    2010-08-01

    The aim of this study was to evaluate the influence of artificial accelerated aging on dimensional stability of two types of acrylic resins (thermally and chemically activated) submitted to different protocols of storage. One hundred specimens were made using a Teflon matrix (1.5 cm x 0.5 mm) with four imprint marks, following the lost-wax casting method. The specimens were divided into ten groups, according to the type of acrylic resin, aging procedure, and storage protocol (30 days). GI: acrylic resins thermally activated, aging, storage in artificial saliva for 16 hours, distilled water for 8 hours; GII: thermal, aging, artificial saliva for 16 hours, dry for 8 hours; GIII: thermal, no aging, artificial saliva for 16 hours, distilled water for 8 hours, GIV: thermal, no aging, artificial saliva for 16 hours, dry for 8 hours; GV: acrylic resins chemically activated, aging, artificial saliva for 16 hours, distilled water for 8 hours; GVI: chemical, aging, artificial saliva for 16 hours, dry for 8 hours; GVII: chemical, no aging, artificial saliva for 16 hours, distilled water for 8 hours; GVIII: chemical, no aging, artificial saliva for 16 hours, dry for 8 hours GIX: thermal, dry for 24 hours; and GX: chemical, dry for 24 hours. All specimens were photographed before and after treatment, and the images were evaluated by software (UTHSCSA - Image Tool) that made distance measurements between the marks in the specimens (mm), calculating the dimensional stability. Data were submitted to statistical analysis (two-way ANOVA, Tukey test, p= 0.05). Statistical analysis showed that the specimens submitted to storage in water presented the largest distance between both axes (major and minor), statistically different (p < 0.05) from control groups. All acrylic resins presented dimensional changes, and the artificial accelerated aging and storage period influenced these alterations.

  14. Human papillomavirus in esophageal squamous cell carcinoma in Colombia and Chile

    PubMed Central

    Castillo, Andres; Aguayo, Francisco; Koriyama, Chihaya; Torres, Miyerlandi; Carrascal, Edwin; Corvalan, Alejandro; Roblero, Juan P; Naquira, Cecilia; Palma, Mariana; Backhouse, Claudia; Argandona, Jorge; Itoh, Tetsuhiko; Shuyama, Karem; Eizuru, Yoshito; Akiba, Suminori

    2006-01-01

    AIM: To examine the presence of human papillomavirus (HPV) in esophageal squamous cell carcinoma (ESCC) specimens collected from Colombia and Chile located in the northern and southern ends of the continent, respectively. METHODS: We examined 47 and 26 formalin-fixed and paraffin-embedded ESCC specimens from Colombia and Chile, respectively. HPV was detected using GP5+/GP6+ primer pair for PCR, and confirmed by Southern blot analysis. Sequencing analysis of L1 region fragment was used to identify HPV genotype. In addition, P16INK4A protein immunostaining of all the specimens was conducted. RESULTS: HPV was detected in 21 ESCC specimens (29%). Sequencing analysis of L1 region fragment identified HPV-16 genome in 6 Colombian cases (13%) and in 5 Chilean cases (19%). HPV-18 was detected in 10 cases (21%) in Colombia but not in any Chilean case. Since Chilean ESCC cases had a higher prevalence of HPV-16 (without statistical significance), but a significantly lower prevalence of HPV-18 than in Colombian cases (P = 0.011) even though the two countries have similar ESCC incidence rates, the frequency of HPV-related ESCC may not be strongly affected by risk factors affecting the incidence of ESCC. HPV-16 genome was more frequently detected in p16 positive carcinomas, although the difference was not statistically significant. HPV-18 detection rate did not show any association with p16 expression. Well-differentiated tumors tended to have either HPV-16 or HPV-18 but the association was not statistically significant. HPV genotypes other than HPV-16 or 18 were not detected in either country. CONCLUSION: HPV-16 and HPV-18 genotypes can be found in ESCC specimens collected from two South American countries. Further studies on the relationship between HPV-16 presence and p16 expression in ESCC would aid understanding of the mechanism underlying the presence of HPV in ESCC. PMID:17036393

  15. Surface hardness evaluation of different composite resin materials: influence of sports and energy drinks immersion after a short-term period

    PubMed Central

    ERDEMİR, Ugur; YİLDİZ, Esra; EREN, Meltem Mert; OZEL, Sevda

    2013-01-01

    Objectives: This study evaluated the effect of sports and energy drinks on the surface hardness of different composite resin restorative materials over a 1-month period. Material and Methods: A total of 168 specimens: Compoglass F, Filtek Z250, Filtek Supreme, and Premise were prepared using a customized cylindrical metal mould and they were divided into six groups (N=42; n=7 per group). For the control groups, the specimens were stored in distilled water for 24 hours at 37º C and the water was renewed daily. For the experimental groups, the specimens were immersed in 5 mL of one of the following test solutions: Powerade, Gatorade, X-IR, Burn, and Red Bull, for two minutes daily for up to a 1-month test period and all the solutions were refreshed daily. Surface hardness was measured using a Vickers hardness measuring instrument at baseline, after 1-week and 1-month. Data were statistically analyzed using Multivariate repeated measure ANOVA and Bonferroni's multiple comparison tests (α=0.05). Results: Multivariate repeated measures ANOVA revealed that there were statistically significant differences in the hardness of the restorative materials in different immersion times (p<0.001) in different solutions (p<0.001). The effect of different solutions on the surface hardness values of the restorative materials was tested using Bonferroni's multiple comparison tests, and it was observed that specimens stored in distilled water demonstrated statistically significant lower mean surface hardness reductions when compared to the specimens immersed in sports and energy drinks after a 1-month evaluation period (p<0.001). The compomer was the most affected by an acidic environment, whereas the composite resin materials were the least affected materials. Conclusions: The effect of sports and energy drinks on the surface hardness of a restorative material depends on the duration of exposure time, and the composition of the material. PMID:23739850

  16. Antibacterial TAP-mimic electrospun polymer scaffold: effects on P. gingivalis-infected dentin biofilm.

    PubMed

    Albuquerque, Maria Tereza P; Evans, Joshua D; Gregory, Richard L; Valera, Marcia C; Bottino, Marco C

    2016-03-01

    This study sought to investigate, in vitro, the effects of a recently developed triple antibiotic paste (TAP)-mimic polymer nanofibrous scaffold against Porphyromonas gingivalis-infected dentin biofilm. Dentin specimens (4 × 4 × 1 mm(3)) were prepared from human canines. The specimens were sterilized, inoculated with P. gingivalis (ATCC 33277), and incubated for 1 week to allow for biofilm formation. Infected dentin specimens were exposed for 3 days to the following treatments: antibiotic-free polydioxanone scaffold (PDS, control), PDS + 25 wt% TAP [25 mg of each antibiotic (metronidazole, ciprofloxacin, and minocycline) per mL of the PDS polymer solution], or a saturated TAP-based solution (50 mg of each antibiotic per mL of saline solution). In order to serve as the negative control, infected dentin specimens were left untreated (bacteria only). To determine the antimicrobial efficacy of the TAP-mimic scaffold, a colony-forming unit (CFU) per milliliter (n = 10/group) measurement was performed. Furthermore, additional specimens (n = 2/group) were prepared to qualitatively study biofilm inhibition via scanning electron microscopy (SEM). Statistics were performed, and significance was set at the 5% level. Both the TAP-mimic scaffold and the positive control (TAP solution) led to complete bacterial elimination, differing statistically (p < 0.05) from the negative control group (bacteria only). No statistical differences were observed for CFU per milliliter data between antibiotic-free scaffolds (2.7 log10 CFU/mL) and the negative control (5.9 log10 CFU/mL). The obtained data revealed significant antimicrobial properties of the novel PDS-based TAP-mimic scaffold against an established P. gingivalis-infected dentin biofilm. Collectively, the data suggest that the proposed nanofibrous scaffold might be used as an alternative to the advocated clinical gold standard (i.e., TAP) for intracanal disinfection prior to regenerative endodontics.

  17. A Comparative Evaluation of the Amount of Fluoride Release and Re-Release after Recharging from Aesthetic Restorative Materials: An in vitro Study.

    PubMed

    Bansal, Ruchika; Bansal, Tajinder

    2015-08-01

    To measure the amount of fluoride released and re released after recharging from various restorative materials: Conventional Glass Ionomer Cement (Fuji II), Light Cure Resin Modified GIC (Fuji II LC), Giomer (Beautifil II), Compomer (Dyract). Fifteen cylindrical specimens were prepared from each material. The specimens were immersed in 20 ml of deionized water. The amount of released fluoride was measured during the 1(st) day, 7(th) day and on the day15 by using specific fluoride electrode and an ion-analyser. After 15 days each material was divided into three Sub Groups of five samples each. Sub Group A served as control, Sub Group B was exposed to 2% NaF solution, Sub Group C to 1000ppm F toothpaste. The amount of fluoride re-released was measured during the 1(st) day, 7(th) day and on the day15 by using specific fluoride electrode and an ion-analyser. The results were statistically analysed using analysis of variance (one-way ANOVA) and Tukey Kramer multiple comparison tests (p≤0.05). Independent of the observation time period of the study the Conventional GIC released the highest amount of fluoride followed by RMGIC, Giomer and Compomer. The initial burst effect was seen with GIC'S but not with Giomer and Compomer. After topical fluoride application fluoride re release was highest in Sub Group B and GIC had a greater recharging ability followed by RMGIC, Giomer and Compomer. The fluoride re release was greatest on 1(st) day followed by rapid return to near exposure levels. From the study it was concluded that, the initial Fluoride release was highest from Conventional GIC followed by Resin Modified GIC, Giomer and Compomer. The Fluoride re release was high when recharging with professional regime (2% NaF) as compared to home regime (Toothpaste). Conventional GIC had a greater recharging ability followed by Resin Modified GIC, Giomer and Compomer.

  18. Geometric morphometric analysis of mandibular shape diversity in Pan.

    PubMed

    Robinson, Chris

    2012-07-01

    The aim of this research is to determine whether geometric morphometric (GM) techniques can provide insights into how the shape of the mandibular corpus differs between bonobos and chimpanzees and to explore the potential implications of those results for our understanding of hominin evolution. We focused on this region of the mandible because of the relative frequency with which it has been recovered in the hominin fossil record. In addition, no previous study had explored in-depth three-dimensional (3D) mandibular corpus shape differences between adults of the two Pan species using geometric morphometrics. GM methods enable researchers to quantitatively analyze and visualize 3D shape changes in skeletal elements and provide an important compliment to traditional two-dimensional analyses. Eighteen mandibular landmarks were collected using a Microscribe 3DX portable digitizer. Specimen configurations were superimposed using Generalized Procrustes analysis and the projections of the fitted coordinates to tangent space were analyzed using multivariate statistics. The size-adjusted corpus shapes of Pan paniscus and Pan troglodytes could be assigned to species with approximately 93% accuracy and the Procrustes distance between the two species was significant. Analyses of the residuals from a multivariate linear regression of the data on centroid size suggested that much of the shape difference between the species is size-related. Chimpanzee subspecies and a small sample of Australopithecus specimens could be correctly identified to taxon, at best, only 75% of the time, although the Procrustes distances between these taxa were significant. The shape of the mandibular symphysis was identified as especially useful in differentiating Pan species from one another. This suggests that this region of the mandible has the potential to be informative for taxonomic analyses of fossil hominoids, including hominins. The results also have implications for phylogenetic hypotheses of hominoid evolution. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Evaluation of a new amplified enzyme immunoassay (EIA) for the detection of Chlamydia trachomatis in male urine, female endocervical swab, and patient obtained vaginal swab specimens

    PubMed Central

    Tanaka, M.; Nakayama, H.; Sagiyama, K.; Haraoka, M.; Yoshida, H.; Hagiwara, T.; Akazawa, K.; Naito, S.

    2000-01-01

    Aims—To compare the performance of a new generation dual amplified enzyme immunoassay (EIA) with a molecular method for the diagnosis of Chlamydia trachomatis, using a range of urogenital samples, and to assess the reliability of testing self collected vaginal specimens compared with clinician collected vaginal specimens. Methods—Two population groups were tested. For the first population group, first void urine samples were collected from 193 male patients with urethritis, and endocervical swabs were collected from 187 high risk commercial sex workers. All urine and endocervical specimens were tested by a conventional assay (IDEIA chlamydia), a new generation amplified immunoassay (IDEIA PCE chlamydia), and the Amplicor polymerase chain reaction (PCR). Discrepant results obtained among the three sample types were confirmed using a nested PCR test with a different plasmid target region. For the second population group, four swab specimens, including one patient obtained vaginal swab, two clinician obtained endocervical swabs, and one clinician obtained vaginal swab, were collected from 91 high risk sex workers. Self collected and clinician collected vaginal swabs were tested by IDEIA PCE chlamydia. Clinician obtained endocervical swabs were assayed by IDEIA PCE chlamydia and Amplicor PCR. Results—The performance of the IDEIA PCE chlamydia test was comparable to that of the Amplicor PCR test when male urine and female endocervical swab specimens were analysed. The relative sensitivities of IDEIA, IDEIA PCE, and Amplicor PCR on male first void urine specimens were 79.3%, 91.4%, and 100%, respectively. The relative sensitivities of the three tests on female endocervical specimens were 85.0%, 95.0%, and 100%, respectively. The positivity rates for patient collected vaginal specimens and clinician collected vaginal specimens by IDEIA PCE were 25.2% and 23.1%, respectively, whereas those for clinician collected endocervical swabs by PCR and IDEIA PCE were both 27.5%. Conclusions—IDEIA PCE chlamydia is a lower cost but sensitive alternative test to PCR for testing male urine samples and female endocervical swabs. In addition, self collected or clinician collected vaginal specimens tested by IDEIA PCE chlamydia are a reliable alternative to analysing endocervical specimens. Key Words: Chlamydia trachomatis • enzyme immunoassay • clinical specimens PMID:10889816

  20. Development of a multivariate model to predict the likelihood of carcinoma in patients with indeterminate peripheral lung nodules after a nondiagnostic bronchoscopic evaluation.

    PubMed

    Voss, Jesse S; Iqbal, Seher; Jenkins, Sarah M; Henry, Michael R; Clayton, Amy C; Jett, James R; Kipp, Benjamin R; Halling, Kevin C; Maldonado, Fabien

    2014-01-01

    Studies have shown that fluorescence in situ hybridization (FISH) testing increases lung cancer detection on cytology specimens in peripheral nodules. The goal of this study was to determine whether a predictive model using clinical features and routine cytology with FISH results could predict lung malignancy after a nondiagnostic bronchoscopic evaluation. Patients with an indeterminate peripheral lung nodule that had a nondiagnostic bronchoscopic evaluation were included in this study (N = 220). FISH was performed on residual bronchial brushing cytology specimens diagnosed as negative (n = 195), atypical (n = 16), or suspicious (n = 9). FISH results included hypertetrasomy (n = 30) and negative (n = 190). Primary study end points included lung cancer status along with time to diagnosis of lung cancer or date of last clinical follow-up. Hazard ratios (HRs) were calculated using Cox proportional hazards regression model analyses, and P values < .05 were considered statistically significant. The mean age of the 220 patients was 66.7 years (range, 35-91), and most (58%) were men. Most patients (79%) were current or former smokers with a mean pack year history of 43.2 years (median, 40; range, 1-200). After multivariate analysis, hypertetrasomy FISH (HR = 2.96, P < .001), pack years (HR = 1.03 per pack year up to 50, P = .001), age (HR = 1.04 per year, P = .02), atypical or suspicious cytology (HR = 2.02, P = .04), and nodule spiculation (HR = 2.36, P = .003) were independent predictors of malignancy over time and were used to create a prediction model (C-statistic = 0.78). These results suggest that this multivariate model including test results and clinical features may be useful following a nondiagnostic bronchoscopic examination. © 2013.

  1. Decreased Neointimal Extracellular Matrix Formation in RAGE-Knockout Mice After Microvascular Denudation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Groezinger, Gerd, E-mail: gerd.groezinger@med.uni-tuebingen.de; Schmehl, Joerg, E-mail: joerg.schmehl@med.uni-tuebingen.de; Bantleon, Ruediger, E-mail: ruediger.bantleon@med.uni-tuebingen.de

    2012-12-15

    Purpose: To evaluate in vivo the role of RAGE (receptor for advanced glycated end products) in the development of restenosis and neointimal proliferation in RAGE-deficient knockout (KO) mice compared with wild-type (WT) mice in an animal model. Materials and Methods: Sixteen WT and 15 RAGE-deficient mice underwent microvascular denudation of the common femoral artery under general anaesthesia. Contralateral arteries underwent a sham operation and served as controls. Four weeks after the intervention, all animals were killed, and paraformaldehyde-fixed specimens of the femoral artery were analysed with different stains (hematoxylin and eosin and Elastica van Gieson) and several different types ofmore » immunostaining (proliferating cell nuclear antigen, {alpha}-actin, collagen, von Willebrand factor, RAGE). Luminal area, area of the neointima, and area of the media were measured in all specimens. In addition, colony-formation assays were performed, and collagen production by WT smooth muscle cells (SMCs) and RAGE-KO SMCs was determined. For statistical analysis, P < 0.05 was considered statistically significant. Results: Four weeks after denudation, WT mice showed a 49.6% loss of luminal area compared with 14.9% loss of luminal area in RAGE-deficient mice (sham = 0% loss) (P < 0.001). The neointima was 18.2 (*1000 {mu}m{sup 2} [n = 15) in the WT group compared with only 8.4 (*1000 {mu}m{sup 2} [n = 16]) in the RAGE-KO group. RAGE-KO SMCs showed significantly decreased proliferation activity and production of extracellular matrix protein. Conclusion: RAGE may be shown to play a considerable role in the formation of neointima leading to restenosis after vascular injury.« less

  2. Influence of Laser Activated Irrigation with two Erbium Lasers on Bond Strength of Inidividually Formed Fiber Reinforced Composite Posts to Root Canal Dentin.

    PubMed

    Parčina, Ivana; Amižić; Miletić, Ivana; Ionescu, Andrei C; Brambilla, Eugenio; Gabrić, Dragana; Baraba, Anja

    2016-12-01

    The aim of this in vitro study was to investigate the effect of laser activated irrigation (LAI) using two erbium lasers on bond strength of individually formed fiber-reinforced composite (FRC) posts to root canal dentin. Twenty-seven single-rooted human teeth were endodontically treated and after post space preparation divided into three groups (n=9 per group), according to the pre-treatment of post space preparation: 1) Conventional syringe irrigation (CSI) and saline; 2) Er.YAG photon-induced photoacoustic streaming (PIPS) technique and saline; 3) Er,Cr:YSGG activated irrigation with RFT2 tip. Two specimens from each group were used for SEM analysis. The remaining specimens (n=7 per group) received individually formed FRC post, everStick POST, luted with self-adhesive cement, G-CEM LinkAce. After cementation, the roots were perpendicularly sectioned into 1 mm thin sections and a push-out test was carried out (0.5 mm/min). The data were calculated as megapascals and were log transformed and statistically analysed using one-way ANOVA at the level of significance set at 5%. In the control group, the smear layer was still present. In the Er:YAG group, the smear layer was removed. In the Er,Cr:YSGG group, the smear layer was partially removed. The Er,Cr:YSGG group achieved the highest bond strength values, followed by the control group and then the Er:YAG group, but no statistically significant difference was found in bond strength values in the tested group of post space pretreatment (p=0.564). LAI using two erbium lasers, with PIPS or RFT2 tip, did not affect the bond strength of individually formed FRC posts to root canal dentin.

  3. Impact of 6-month frozen storage of cervical specimens in alkaline buffer conditions on human papillomavirus genotyping.

    PubMed

    LaMere, Brandon J; Howell, Renee; Fetterman, Barbara; Shieh, Jen; Castle, Philip E

    2008-08-01

    The impact of 6-month storage of cervical specimens under alkaline conditions that occurs as the result of Hybrid Capture 2 testing on human papillomavirus (HPV) genotyping is not well documented. To examine this issue, 143 frozen hc2-positive specimens in specimen transport medium were selected at random from each of the following groups: specimens stored for 6 months, 4 months, and 2.5 months under alkaline pH (pH 12-13) and specimens stored 1 month at neutral pH (pH 6-7) as controls. Specimens were tested in a masked fashion for 20 HPV genotypes (HPV6, 11, 16, 18, 26, 31, 33, 35, 39, 45, 51, 52, 53, 56, 58, 59, 66, 68, 73, and 82) using a prototype, research-use-only GP5+/6+ L1 consensus PCR method and multiplex hybridization using Luminex xMAP for detection of specific HPV genotypes One control specimen had missing test results. There were no statistical differences in the number of HPV genotypes detected, number of carcinogenic HPV genotypes detected, or in the signal strength among HPV-positive results across groups. Six-month frozen storage of cervical specimens at alkaline pH had little impact on testing for HPV genotypes among hc2-positive women using this HPV genotyping method.

  4. [Effect of bleaching agents on the color of indirect and direct composite resins].

    PubMed

    Xing, Wenzhong; Jiang, Tao; Chen, Xiaodong; Wang, Yining

    2014-09-01

    To evaluate the effect of bleaching agents on the color of indirect and direct composite resins. Five resin composite materials were tested in this in vitro study. The five composites were as follow: two indirect composite resins (Adoro SR, Ceramage) and three direct composite resins (Filtek Z350, Clearfil Majesty Esthetic, and Gradia Direct Anterior). For each material, twenty disk-shaped specimens were prepared and randomly divided into five groups according to the color parameters of specimens before bleaching treatment. The composite resin specimens were treated by one of five sample solutions which were at-home bleaching agents (10% and 15% carbarmide peroxide), in- office bleaching agents (38% H(2)O(2) and 35%H(2)O(2)) and deionized water (control group). The color parameters of specimens were measured by spectrophotometer at baseline and after bleaching treatments. The color differences (ΔE values) between baseline and post-treatments were calculated. The data of color differences were evaluated statistically using two-way analysis with a significance level of 0.05. The color changes of the resin composites were less than 2.0 after bleaching agent treatment, therefore were not perceptible. Slight increase of L(*) values and decrease of C(*)ab values in color parameters of specimens were observed. There were statistically significant differences in ΔE values for different bleaching treatments and resin materials (P = 0.001). The bleaching agents did not affect the color of indirect and direct composite resins tested.

  5. Deformation measurements of composite multi-span beam shear specimens by Moire interferometry

    NASA Technical Reports Server (NTRS)

    Post, D.; Czarnek, R.; Joh, D.; Wood, J.

    1984-01-01

    Experimental analyses were performed for determination of in plane deformations and shear strains in unidirectional and quasi-isotropic graphite-epoxy beams. Forty-eight ply beams were subjected to 5 point and 3 point flexure. Whole field measurements were recorded at load levels from about 20% to more than 90% of failure loads. Contour maps of U and W displacement fields were obtained by moire interferometry, using reference gratings of 2400 lines/mm. Clearly defined fringes with fringe orders exceeding 1000 were obtained. Whole field contour maps of shear strains were obtained by a method developed for these tests. Various anomalous effects were detected in the displacement fields. Their analysis indicated excess shear strains in resin rich zones in regions of shear tractions; free edge shear strains in quasi-isotropic specimens in regions of normal stresses; and shear stresses associated with cyclic shear compliances of quasi-isotropic plies in regions of shear tractions. Their contributions could occur independently or in superposition. Qualitative analyses addressed questions of relaxation; influence of contact stress distribution; specimen failure; effect of specimen overhang; nonlinearity; and qualities of 5 and 3 point flexure tests.

  6. Quantifications of dendrochronological information from contrasting microdensitometric measuring circumstances of experimental wood samples.

    PubMed

    Helama, S; Bégin, Y; Vartiainen, M; Peltola, H; Kolström, T; Meriläinen, J

    2012-06-01

    We analyzed how the pretreatment method of Scots pine (Pinus sylvestris L.) wood specimens together with X-ray methodology applied for density analyses affect resulting tree-ring data and derived proxy-based climate information. We also evaluated whether these results from two contrasting laboratory circumstances could be homogenized by applying dendroclimatic statistical methods. For this study, we measured a pair of X-ray based microdensitometry datasets using double samples of subfossil and recent wood specimens. Dendrochronological information of earlywood and latewood series was examined to determine for alterations in the resulting data. We found that the level of overall density, its trend over cambial ages and the growth amplitude altered due to the sample pretreatment/density measuring exercise, which means that comparisons of heterogeneous datasets should be, in general, regarded cautiously. Dendrochronological standardization did, however, even out several potentially biasing influences from the differing overall densities and their trends. The two latewood (maximum) density chronologies yielded paleoclimatic reconstructions which both calibrated and verified satisfactorily with the instrumental warm-season (March-September) mean temperatures. The transfer functions were found to further equalize the differences between the two proxy records. We recommend (if no strictly homogenous data are available) reconciling similar data assemblages through transfer functions with multiple independent variables. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Geometric morphometrics in primatology: craniofacial variation in Homo sapiens and Pan troglodytes.

    PubMed

    Lynch, J M; Wood, C G; Luboga, S A

    1996-01-01

    Traditionally, morphometric studies have relied on statistical analysis of distances, angles or ratios to investigate morphometric variation among taxa. Recently, geometric techniques have been developed for the direct analysis of landmark data. In this paper, we offer a summary (with examples) of three of these newer techniques, namely shape coordinate, thin-plate spline and relative warp analyses. Shape coordinate analysis detected significant craniofacial variation between 4 modern human populations, with African and Australian Aboriginal specimens being relatively prognathous compared with their Eurasian counterparts. In addition, the Australian specimens exhibited greater basicranial flexion than all other samples. The observed relationships between size and craniofacial shape were weak. The decomposition of shape variation into affine and non-affine components is illustrated via a thin-plate spline analysis of Homo and Pan cranial landmarks. We note differences between Homo and Pan in the degree of prognathism and basicranial flexion and the position and orientation of the foramen magnum. We compare these results with previous studies of these features in higher primates and discuss the utility of geometric morphometrics as a tool in primatology and physical anthropology. We conclude that many studies of morphological variation, both within and between taxa, would benefit from the graphical nature of these techniques.

  8. Diagnostic performances of clinical laboratory tests using Triton X-100 to reduce the biohazard associated with routine testing of Ebola virus-infected patients.

    PubMed

    Tempestilli, Massimo; Pucci, Luigia; Notari, Stefania; Di Caro, Antonino; Castilletti, Concetta; Rivelli, Maria Rosaria; Agrati, Chiara; Pucillo, Leopoldo Paolo

    2015-11-01

    Ebola virus, an enveloped virus, is the cause of the largest and most complex Ebola virus disease (EVD) outbreak in West Africa. Blood or body fluids of an infected person may represent a biohazard to laboratory workers. Laboratory tests of virus containing specimens should be conducted in referral centres at biosafety level 4, but based on the severity of clinical symptoms, basic laboratories might be required to execute urgent tests for patients suspected of EVD. The aim of this work was to compare the analytical performances of laboratory tests when Triton X-100, a chemical agent able to inactivate other enveloped viruses, was added to specimens. Results of clinical chemistry, coagulation and haematology parameters on samples before and after the addition of 0.1% (final concentration) of Triton X-100 and 1 h of incubation at room temperature were compared. Overall, results showed very good agreement by all statistical analyses. Triton X-100 at 0.1% did not significantly affect the results for the majority of the analytes tested. Triton X-100 at 0.1% can be used to reduce the biohazard in performing laboratory tests on samples from patients with EVD without affecting clinical decisions.

  9. Evaluation of the effect of a home bleaching agent on surface characteristics of indirect esthetic restorative materials--part II microhardness.

    PubMed

    Torabi, Kianoosh; Rasaeipour, Sasan; Ghodsi, Safoura; Khaledi, Amir Ali Reza; Vojdani, Mahroo

    2014-07-01

    The exponential usage of esthetic restorative materials is beholden to society needs and desires. Interaction between the bleaching agents and the esthetic restorative materials is of critical importance. This in vitro study has been conducted to evaluate the effect of a home bleaching agent, carbamide peroxide (CP) 38%, on the microhardness of the fiber reinforced composite (FRC), overglazed, autoglazed, or polished porcelain specimens. For overglazed, autoglazed, polished ceramics and also FRC cylindrical specimens (n = 20 per group) were prepared. The specimens were stored in distilled water at 37°C for 48 hours prior to testing. Six samples from each group were selected randomly as negative controls which were stored in distilled water at 37°C that was changed daily. CP 38% was applied on the test specimens for 15 minutes, twice a day for 14 days. By using Knoop-microhardness tester microhardness testing for baseline, control and test specimens was conducted. Data were statistically analyzed using paired t-test, Mann-Whitney test, and Kruskal-Wallis test. Home bleaching significantly decreased the surface microhardness of all the test samples (p < 0.05), whereas the control groups did not show statistically significant changes after 2 weeks. The polished porcelain and polished composite specimens showed the most significant change in microhard-ness after bleaching process (p < 0.05). Although the type of surface preparation affects the susceptibility of the porcelain surface to the bleaching agent, no special preparation can preclude such adverse effects. The contact of home bleaching agents with esthetic restorative materials is unavoidable. Therefore protecting these restorations from bleaching agents and reglazing or at least polishing the restorations after bleaching is recommended.

  10. Effects of anterior offsetting of humeral head component in posteriorly unstable total shoulder arthroplasty: Finite element modeling of cadaver specimens.

    PubMed

    Lewis, Gregory S; Conaway, William K; Wee, Hwabok; Kim, H Mike

    2017-02-28

    A novel technique of "anterior offsetting" of the humeral head component to address posterior instability in total shoulder arthroplasty has been proposed, and its biomechanical benefits have been previously demonstrated experimentally. The present study sought to characterize the changes in joint mechanics associated with anterior offsetting with various amounts of glenoid retroversion using cadaver specimen-specific 3-dimensional finite element models. Specimen-specific computational finite element models were developed through importing digitized locations of six musculotendinous units of the rotator cuff and deltoid muscles based off three cadaveric shoulder specimens implanted with total shoulder arthroplasty in either anatomic or anterior humeral head offset. Additional glenoid retroversion angles (0°, 10°, 20°, and 30°) other than each specimen׳s actual retroversion were modeled. Contact area, contact force, peak pressure, center of pressure, and humeral head displacement were calculated at each offset and retroversion for statistical analysis. Anterior offsetting was associated with significant anterior shift of center of pressure and humeral head displacement upon muscle loading (p<0.05). Although statistically insignificant, anterior offsetting was associated with increased contact area and decreased peak pressure (p > 0.05). All study variables showed significant differences when compared between the 4 different glenoid retroversion angles (p < 0.05) except for total force (p < 0.05). The study finding suggests that the anterior offsetting technique may contribute to joint stability in posteriorly unstable shoulder arthroplasty and may reduce eccentric loading on glenoid components although the long term clinical results are yet to be investigated in future. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Translucency of zirconia-based pressable ceramics with different core and veneer thicknesses.

    PubMed

    Jeong, Il-Do; Bae, So-Yeon; Kim, Dong-Yeon; Kim, Ji-Hwan; Kim, Woong-Chul

    2016-06-01

    Little information is available on the translucency of zirconia-based pressable ceramic restorations with a pressed ceramic veneer and zirconia core in various thickness combinations. The purpose of this in vitro study was to assess the translucency of 3 types of zirconia-based pressable ceramics for different core-veneer thickness combinations. A bilayered ceramic specimen was prepared with a pressable ceramic (IPS e.max Zirpress, Initial IQ, Rosetta UltraPress) veneer over a zirconia core (Zenostar Zr). Three groups of specimens (n=7) were formed with the following core+veneer thicknesses: 1 +0.5 mm, 0.7 +0.8 mm, and 0.5 +1 mm. To obtain consistent thickness and high translucency, all specimens were subjected to surface grinding with a grinding machine. To eliminate the effect of differences in roughness on the translucency, the surface roughness of the ground specimens was measured with a scanning profiler, and the consistency of these measured values was verified through statistical analysis. The luminous transmittance of the specimens was measured with a spectrophotometer. The effects of the pressable ceramic type and core-veneer thickness combination on transmittance were assessed using a 2-way ANOVA (α=.05). The consistency of the surface roughness among the tested specimens was confirmed using a 1-way ANOVA and the Tukey HSD post hoc test (P<.05). The luminous transmittance exhibited a statistically significant dependence on both the type of pressable ceramic and the core-veneer thickness combination (P<.05). The type of pressable ceramic and core-veneer thickness combination affected the translucency of the restoration. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. A Comparative Study of the Retentive Strengths of Commercial and Indigenously Developed Luting Cements using Both Lathe-cut and Clinically Simulated Specimens.

    PubMed

    Mathew, Joe; Kurian, Byju P; Philip, Biju; Mohammed, Sunil; Menon, Preetha; Raj, Rajan S

    2016-08-01

    Superior adhesive strength in luting agents is of paramount significance in fixed partial denture success. In this in vitro study five cements were tested for retentive qualities, using both lathe-cut and hand-prepared specimens. A total of 104 freshly extracted tooth specimens were prepared. Seventy of them were lathe-cut and 30 specimens were hand-prepared to simulate clinical conditions. Five different cements were tested, which included a compomer, a composite, a zinc phosphate, and 2 glass-ionomer luting cements. Of the 5, 2 trial cements were indigenously developed by Sree Chitra Tirunal Institute for Medical Sciences and Technology (SCTIMST), Trivandrum, India - a glass-ionomer cement (Chitra GIC) and a chemical-cure composite (Chitra CCC). All cements were compared within each group and between groups (lathe-prepared and hand-prepared). GC Fuji 1 (GC America) exhibited superior retentive strengths in both lathe-cut and hand-prepared specimens, whereas the compomer cement displayed the lowest values when tested. In lathe-cut specimens, statistical analysis showed no significant difference between GC Fuji 1 and indigenously developed Chitra CCC. Both Chitra CCC and GC Fuji 1 have comparable strengths in lathe-cut samples, making Chitra CCC a potential luting agent. Statistical analysis reveals that all cements, except GC Fuji 1, exhibited a significant decrease in strength due to the change in design uniformity. The chemical bonding of GC Fuji 1 proves to be quite strong irrespective of shape and precision of the tooth crown. The indigenously developed Chitra GIC and Chitra CCC showed promising results to be used as a potential luting agent.

  13. Atomic force microscopy and tridimensional topography analysis of human enamel after resinous infiltration and storage in water.

    PubMed

    Taher, Nadia M

    2013-04-01

    To evaluate the effect of water storage on surface roughness (Ra) of human enamel after treatment with resin infiltrant and fissure sealant, by utilizing atomic force microscopy (AFM) and microtomography. This study was conducted after registration and ethical approval clarification at the College of Dentistry Research Center, King Saud University, Riyadh, Kingdom of Saudi Arabia between January 2011 and August 2011. Thirty enamel surface specimens were prepared from caries-free human premolar teeth. Specimens were divided into 3 groups: Group I, was the control; Group II, a resin infiltrant (Icon) was applied on the enamel surfaces; and Group III, the teeth were treated with fissure sealant (SealRite). All specimens were stored in distilled water for 6 months and then, subjected to AFM Veeco CP11 1.2 analysis. A few specimens were scanned by skyscan-1072-x-ray microtomography. The Ra mean readings were recorded and statistical analysis was performed with the Statistical Package for Social Sciences Version 16 at the significance level of p<0.05. No significant differences in the mean Ra were recorded among the 3 groups, (Group I = 0.21+/-0.057), (Group II = 0.23+/-0.075), and (Group III = 0.20+/-0.039) at p=0.747. The AFM images of enamel surface show thin and inhomogeneous Icon resin in Group II, meanwhile, the SealRite in Group III showed a homogeneous layer in all specimens. The microtomography supported the findings of the AFM images. The persistence of the SealRite in all specimens revealed its low solubility in water and its protective effect on enamel surface.

  14. Trends in performance of the National Measles Case-Based Surveillance System, Ministry of Health and Child Welfare, Zimbabwe (1999 - 2008)

    PubMed Central

    Choto, Regis; Chadambuka, Addmore; Shambira, Gerald; Gombe, Notion; Tshimanga, Mufuta; Midzi, Stanley; Mberikunashe, Joseph

    2012-01-01

    Introduction Since adoption of the measles case-based surveillance system in Zimbabwe in 1998, data has been routinely collected at all levels of the health delivery system and sent to national level with little or no documented evidence of use to identify risky populations, monitor impact of interventions and measure progress towards achieving measles elimination. We analysed this data to determine trends in the national measles case-based surveillance system (NMCBSS). Methods A retrospective record review of the NMCBSS dataset for period 1999 –2008 was conducted, assessing trends in proportions of investigated cases; timeliness and nature of specimens received at laboratory; timeliness of feedback of serology results, proportion of cases confirmed as measles and national annualized rates of investigation. Comparisons with WHO performance indicators were done. The secondary data analysis was done in Excel and Epi-Info statistical software. Results Cumulatively 4994 suspected cases were reported and investigated between 1999 and 2008. Reported suspected and confirmed measles cases declined from 24, 5% and 5.9% respectively in 2000 to 3.9% and 1.0% respectively in 2008. Proportion of cases with blood specimens collected and proportion reaching laboratory timely increased from 83% and 65% respectively in 1999, to 100% and 82% respectively in 2008. Proportion of specimens arriving at laboratory in good condition improved from 65% in 2004 to 94% in 2008 while timeliness of feedback of serology results improved from 4% in 2004 to 65% in 2008. Sensitivity of the NMCBSS however has been weakening, declining from 9.04 cases investigated per 100 000 population per year in 2000 to 1.58 cases/100 000/year in 2008. Conclusion The NMCBSS improved in quality, timeliness and feedback of laboratory results of specimens sent for investigation, but its sensitivity declined mainly due to reduced capacity to detect and confirm measles cases. We recommend training staff on active surveillance of cases and more support and supervisory visits to strengthen EPI surveillance. PMID:22368745

  15. Multilocus Phylogeny of the Afrotropical Freshwater Crab Fauna Reveals Historical Drainage Connectivity and Transoceanic Dispersal Since the Eocene.

    PubMed

    Daniels, Savel R; Phiri, Ethel E; Klaus, Sebastian; Albrecht, Christian; Cumberlidge, Neil

    2015-07-01

    Phylogenetic reconstruction, divergence time estimations and ancestral range estimation were undertaken for 66% of the Afrotropical freshwater crab fauna (Potamonautidae) based on four partial DNA loci (12S rRNA, 16S rRNA, cytochrome oxidase one [COI], and histone 3). The present study represents the most comprehensive taxonomic sampling of any freshwater crab family globally, and explores the impact of paleodrainage interconnectivity on cladogenesis among freshwater crabs. Phylogenetic analyses of the total evidence data using maximum-likelihood (ML), maximum parsimony (MP), and Bayesian inference (BI) produced a robust statistically well-supported tree topology that reaffirmed the monophyly of the Afrotropical freshwater crab fauna. The estimated divergence times suggest that the Afrotropical Potamonautidae diverged during the Eocene. Cladogenesis within and among several genera occurred predominantly during the Miocene, which was associated with major tectonic and climatic ameliorations throughout the region. Paleodrainage connectivity was observed with specimens from the Nilo-Sudan and East African coast proving to be sister to specimens from the Upper Guinea Forests in West Africa. In addition, we observed strong sister taxon affinity between specimens from East Africa and the Congo basin, including specimens from Lake Tanganyika, while the southern African fauna was retrieved as sister to the Angolan taxa. Within the East African clade we observed two independent transoceanic dispersal events, one to the Seychelles Archipelago and a second to Madagascar, while we observe a single transoceanic dispersal event from West Africa to São Tomé. The ancestral area estimation suggested a West African/East African ancestral range for the family with multiple dispersal events between southern Africa and East Africa, and between East Africa and Central Africa The taxonomic implications of our results are discussed in light of the widespread paraphyly evident among a number of genera. © The Author(s) 2015. Published by Oxford University Press, on behalf of the Society of Systematic Biologists. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. A new laser reflectance system capable of measuring changing cross-sectional area of soft tissues during tensile testing.

    PubMed

    Pokhai, Gabriel G; Oliver, Michele L; Gordon, Karen D

    2009-09-01

    Determination of the biomechanical properties of soft tissues such as tendons and ligaments is dependent on the accurate measurement of their cross-sectional area (CSA). Measurement methods, which involve contact with the specimen, are problematic because soft tissues are easily deformed. Noncontact measurement methods are preferable in this regard, but may experience difficulty in dealing with the complex cross-sectional shapes and glistening surfaces seen in soft tissues. Additionally, existing CSA measurement systems are separated from the materials testing machine, resulting in the inability to measure CSA during testing. Furthermore, CSA measurements are usually made in a different orientation, and with a different preload, prior to testing. To overcome these problems, a noncontact laser reflectance system (LRS) was developed. Designed to fit in an Instron 8872 servohydraulic test machine, the system measures CSA by orbiting a laser transducer in a circular path around a soft tissue specimen held by tissue clamps. CSA measurements can be conducted before and during tensile testing. The system was validated using machined metallic specimens of various shapes and sizes, as well as different sizes of bovine tendons. The metallic specimens could be measured to within 4% accuracy, and the tendons to within an average error of 4.3%. Statistical analyses showed no significant differences between the measurements of the LRS and those of the casting method, an established measurement technique. The LRS was successfully used to measure the changing CSA of bovine tendons during uniaxial tensile testing. The LRS developed in this work represents a simple, quick, and accurate way of reconstructing complex cross-sectional profiles and calculating cross-sectional areas. In addition, the LRS represents the first system capable of automatically measuring changing CSA of soft tissues during tensile testing, facilitating the calculation of more accurate biomechanical properties.

  17. Effect of thickness and surface modifications on flexural strength of monolithic zirconia.

    PubMed

    Ozer, Fusun; Naden, Andrew; Turp, Volkan; Mante, Francis; Sen, Deniz; Blatz, Markus B

    2017-10-14

    A recommended minimum thickness for monolithic zirconia restorations has not been reported. Assessing a proper thickness that has the necessary load-bearing capacity but also conserves dental hard tissues is essential. The purpose of this in vitro study was to evaluate the effect of thickness and surface modifications on monolithic zirconia after simulated masticatory stresses. Monolithic zirconia disks (10 mm in diameter) were fabricated with 1.3 mm and 0.8 mm thicknesses. For each thickness, 21 disks were fabricated. The specimens of each group were further divided into 3 subgroups (n=7) according to the surface treatments applied: untreated (control), airborne-particle abrasion with 50-μm Al 2 O 3 particles at a pressure of 400 kPa at 10 mm, and grinding with a diamond rotary instrument followed by polishing. The biaxial flexure strength was determined by using a piston-on-3-balls technique in a universal testing machine. Flexural loading was applied with a 1.4-mm diameter steel cylinder, centered on the disk, at a crosshead speed of 0.5 mm/min until fracture occurred. X-ray diffraction (XRD) and scanning electron microscopy (SEM) analyses were performed. The data were statistically analyzed with 2-way ANOVA, Tamhane T2, 1-way ANOVA, and Student t tests (α=.05). The 1.3-mm specimens had significantly higher flexural strength than the 0.8-mm specimens (P<.05). Airborne-particle abrasion significantly increased the flexural strength (P<.05). Grinding and polishing did not affect the flexural strength of the specimens (P>.05). The mean flexural strength of 0.8-mm and 1.3-mm thick monolithic zirconia was greater than reported masticatory forces. Airborne-particle abrasion increased the flexural strength of monolithic zirconia. Grinding did not affect flexural strength if subsequently polished. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  18. Archaeological Investigations at Site 45-DO-326, Chief Joseph Dam Project, Washington.

    DTIC Science & Technology

    1984-01-01

    Neal Crozier, Sarah K. Campbell and Julia E. Hammett wrote Chapter 2. Stephanie Livingston analyzed .- the faunal assemblage and wrote Chapter 4. Dorothy...mathematical equations derived from analysis of cases with known memberships. First, we assembled representative specimens for each -~~ ~ ,%, -. 79 Table 3-25...we used derived equations called discriminant functions to assign specimens In our collection lo the statistically defined projectile point types

  19. Comminuted olecranon fracture fixation with pre-contoured plate: Comparison of composite and cadaver bones

    PubMed Central

    Hamilton Jr, David A; Reilly, Danielle; Wipf, Felix; Kamineni, Srinath

    2015-01-01

    AIM: To determine whether use of a precontoured olecranon plate provides adequate fixation to withstand supraphysiologic force in a comminuted olecranon fracture model. METHODS: Five samples of fourth generation composite bones and five samples of fresh frozen human cadaveric left ulnae were utilized for this study. The cadaveric specimens underwent dual-energy X-ray absorptiometry (DEXA) scanning to quantify the bone quality. The composite and cadaveric bones were prepared by creating a comminuted olecranon fracture and fixed with a pre-contoured olecranon plate with locking screws. Construct stiffness and failure load were measured by subjecting specimens to cantilever bending moments until failure. Fracture site motion was measured with differential variable resistance transducer spanning the fracture. Statistical analysis was performed with two-tailed Mann-Whitney-U test with Monte Carlo Exact test. RESULTS: There was a significant difference in fixation stiffness and strength between the composite bones and human cadaver bones. Failure modes differed in cadaveric and composite specimens. The load to failure for the composite bones (n = 5) and human cadaver bones (n = 5) specimens were 10.67 nm (range 9.40-11.91 nm) and 13.05 nm (range 12.59-15.38 nm) respectively. This difference was statistically significant (P ˂ 0.007, 97% power). Median stiffness for composite bones and human cadaver bones specimens were 5.69 nm/mm (range 4.69-6.80 nm/mm) and 7.55 nm/mm (range 6.31-7.72 nm/mm). There was a significant difference for stiffness (P ˂ 0.033, 79% power) between composite bones and cadaveric bones. No correlation was found between the DEXA results and stiffness. All cadaveric specimens withstood the physiologic load anticipated postoperatively. Catastrophic failure occurred in all composite specimens. All failures resulted from composite bone failure at the distal screw site and not hardware failure. There were no catastrophic fracture failures in the cadaveric specimens. Failure of 4/5 cadaveric specimens was defined when a fracture gap of 2 mm was observed, but 1/5 cadaveric specimens failed due to a failure of the triceps mechanism. All failures occurred at forces greater than that expected in postoperative period prior to healing. CONCLUSION: The pre-contoured olecranon plate provides adequate fixation to withstand physiologic force in a composite bone and cadaveric comminuted olecranon fracture model. PMID:26495247

  20. Electrochemical corrosion and surface analyses of a ni-cr alloy in bleaching agents.

    PubMed

    Tamam, Evşen; Aydın, A Kevser; Bilgiç, Semra

    2014-10-01

    The aim of this study was to evaluate the corrosion behavior of a Ni-Cr dental casting alloy subjected to 10% hydrogen peroxide (HP) and 10% carbamide peroxide (CP) bleaching solutions and to determine the composition of the surface oxide layer formed on the alloy specimens. Ten cylindrical specimens (4 mm in diameter × 25 mm in height) were cast from a Ni-Cr alloy (Wiron 99) and divided into two groups (n = 5). A potentiodynamic polarization test was used to compare the corrosion rates of specimens in HP and CP (pH = 6.5). Before cyclic polarization tests, all alloy specimens were allowed to reach a steady open circuit potential (Ecorr ) for a period of 1 hour. Then tests were initiated at 100 mV versus standard calomel electrode (SCE) below Ecorr and scanned at a rate of 1 mV/s in the anodic direction until reaching 1000 mV over the Ecorr value. The scan then was reversed back to the Ecorr of the specimens. The open circuit potentials (Ecorr ) and the current densities (Icorr ) were determined using the anodic Tafel regions extrapolating from the curves. Differences in Ecorr and Icorr were determined using one-way ANOVA (α = 0.05). In addition, corrosion rates were calculated from these curves. Before and after polarization tests, a scanning electron microscope (SEM) examination accompanied by energy dispersive X-ray spectroscopy (EDS) was used to analyze the surface morphology. The surface characterization of the passive film formed on alloy specimens was also performed by using X-ray photoelectron spectroscopy (XPS). In this study, bleaching agents had an effect on the anodic process for two groups. Although no statistical difference was identified between the groups for both corrosion parameters, results indicated that the effect of CP on the corrosion behavior was less than that of HP. These results agreed with the SEM observations. XPS data showed that oxide layers formed on all groups contained mainly Cr2 O3 , NiO, and MoO3 , and the amounts of oxides formed on CP-treated specimens were higher than HP treated ones. Also, molybdenum rates were increased with CP application compared to HP. The comparison of the effects of the two bleaching agents at 10% showed that the alloy suffered less corrosion with CP than HP. This result was also confirmed by the SEM and XPS data. The presence of Mo on the oxide layer affected the oxide layer, leading to lower corrosion rates. © 2014 by the American College of Prosthodontists.

  1. Analysis of the microstructure and mechanical performance of composite resins after accelerated artificial aging.

    PubMed

    De Oliveira Daltoé, M; Lepri, C Penazzo; Wiezel, J Guilherme G; Tornavoi, D Cremonezzi; Agnelli, J A Marcondes; Reis, A Cândido Dos

    2013-03-01

    Researches that assess the behavior of dental materials are important for scientific and industrial development especially when they are tested under conditions that simulate the oral environment, so this work analyzed the compressive strength and microstructure of three composite resins subjected to accelerated artificial aging (AAA). Three composites resins of 3M (P90, P60 and Z100) were analyzed and were obtained 16 specimens for each type (N.=48). Half of each type were subjected to UV-C system AAA and then were analyzed the surfaces of three aged specimens and three not aged of each type through the scanning electron microscope (SEM). After, eight specimens of each resin, aged and not aged, were subjected to compression test. After statistical analysis of compressive strength values, it was found that there was difference between groups (α <0.05). The resin specimens aged P60 presented lower values of compressive strength statistically significant when compared to the not subject to the AAA. For the other composite resins, there was no difference, regardless of aging, a fact confirmed by SEM. The results showed that the AAA influenced the compressive strength of the resin aged P60; confirmed by surface analysis by SEM, which showed greater structural disarrangement on surface material.

  2. Application of adenosine triphosphate-driven bioluminescence for quantification of plaque bacteria and assessment of oral hygiene in children.

    PubMed

    Fazilat, Shahram; Sauerwein, Rebecca; McLeod, Jennifer; Finlayson, Tyler; Adam, Emilia; Engle, John; Gagneja, Prashant; Maier, Tom; Machida, Curtis A

    2010-01-01

    Dentistry has undergone a shift in caries management toward prevention and improved oral hygiene and diagnosis. Caries prevention now represents one of the most important aspects of modern dental practice. The purpose of this cross-sectional study was to demonstrate the use of adenosine triphosphate- (ATP-) driven bioluminescence as an innovative tool for the rapid chairside enumeration of oral bacteria (including plague streptococci) and assessment of oral hygiene and caries risk. Thirty-three pediatric patients (7- to 12-year-old males and females) were examined, and plague specimens, in addition to stimulated saliva, were collected from representative teeth within each quadrant. Oral specimens (n=150 specimens) were assessed by plating on enriched and selective agars, to enumerate total bacteria and streptococci, and subjected to adenosine triphosphate- (ATP-) driven bioluminescence determinations using a luciferase-based assay system. Statistical correlations, linking ATP values to numbers of total bacteria, oral streptococci and mutans streptococci, yielded highly significant r values of 0.854, 0.840, and 0.796, respectively Our clinical data is consistent with the hypothesis that ATP measurements have a strong statistical association with bacterial number in plague and saliva specimens, including numbers for oral streptococci, and may be used as a potential assessment tool for oral hygiene and caries risk in children.

  3. Weibull analysis of fracture test data on bovine cortical bone: influence of orientation.

    PubMed

    Khandaker, Morshed; Ekwaro-Osire, Stephen

    2013-01-01

    The fracture toughness, K IC, of a cortical bone has been experimentally determined by several researchers. The variation of K IC values occurs from the variation of specimen orientation, shape, and size during the experiment. The fracture toughness of a cortical bone is governed by the severest flaw and, hence, may be analyzed using Weibull statistics. To the best of the authors' knowledge, however, no studies of this aspect have been published. The motivation of the study is the evaluation of Weibull parameters at the circumferential-longitudinal (CL) and longitudinal-circumferential (LC) directions. We hypothesized that Weibull parameters vary depending on the bone microstructure. In the present work, a two-parameter Weibull statistical model was applied to calculate the plane-strain fracture toughness of bovine femoral cortical bone obtained using specimens extracted from CL and LC directions of the bone. It was found that the Weibull modulus of fracture toughness was larger for CL specimens compared to LC specimens, but the opposite trend was seen for the characteristic fracture toughness. The reason for these trends is the microstructural and extrinsic toughening mechanism differences between CL and LC directions bone. The Weibull parameters found in this study can be applied to develop a damage-mechanics model for bone.

  4. Dimensional changes of acrylic resin denture bases: conventional versus injection-molding technique.

    PubMed

    Gharechahi, Jafar; Asadzadeh, Nafiseh; Shahabian, Foad; Gharechahi, Maryam

    2014-07-01

    Acrylic resin denture bases undergo dimensional changes during polymerization. Injection molding techniques are reported to reduce these changes and thereby improve physical properties of denture bases. The aim of this study was to compare dimensional changes of specimens processed by conventional and injection-molding techniques. SR-Ivocap Triplex Hot resin was used for conventional pressure-packed and SR-Ivocap High Impact was used for injection-molding techniques. After processing, all the specimens were stored in distilled water at room temperature until measured. For dimensional accuracy evaluation, measurements were recorded at 24-hour, 48-hour and 12-day intervals using a digital caliper with an accuracy of 0.01 mm. Statistical analysis was carried out by SPSS (SPSS Inc., Chicago, IL, USA) using t-test and repeated-measures ANOVA. Statistical significance was defined at P<0.05. After each water storage period, the acrylic specimens produced by injection exhibited less dimensional changes compared to those produced by the conventional technique. Curing shrinkage was compensated by water sorption with an increase in water storage time decreasing dimensional changes. Within the limitations of this study, dimensional changes of acrylic resin specimens were influenced by the molding technique used and SR-Ivocap injection procedure exhibited higher dimensional accuracy compared to conventional molding.

  5. Surface roughness of glass ionomer cements indicated for uncooperative patients according to surface protection treatment

    PubMed Central

    Pacifici, Edoardo; Bossù, Maurizio; Giovannetti, Agostino; La Torre, Giuseppe; Guerra, Fabrizio; Polimeni, Antonella

    2013-01-01

    Summary Background Even today, use of Glass Ionomer Cements (GIC) as restorative material is indicated for uncooperative patients. Aim The study aimed at estimating the surface roughness of different GICs using or not their proprietary surface coatings and at observing the interfaces between cement and coating through SEM. Materials and methods Forty specimens have been obtained and divided into 4 groups: Fuji IX (IX), Fuji IX/G-Coat Plus (IXC), Vitremer (V), Vitremer/Finishing Gloss (VFG). Samples were obtained using silicone moulds to simulate class I restorations. All specimens were processed for profilometric evaluation. The statistical differences of surface roughness between groups were assessed using One-Way Analysis of Variance (One-Way ANOVA) (p<0.05). The Two-Way Analysis of Variance (Two-Way ANOVA) was used to evaluate the influence of two factors: restoration material and presence of coating. Coated restoration specimens (IXC and VFG) were sectioned perpendicular to the restoration surface and processed for SEM evaluation. Results No statistical differences in roughness could be noticed between groups or factors. Following microscopic observation, interfaces between restoration material and coating were better for group IXC than for group VFG. Conclusions When specimens are obtained simulating normal clinical procedures, the presence of surface protection does not significantly improve the surface roughness of GICs. PMID:24611090

  6. Surface roughness of glass ionomer cements indicated for uncooperative patients according to surface protection treatment.

    PubMed

    Pacifici, Edoardo; Bossù, Maurizio; Giovannetti, Agostino; La Torre, Giuseppe; Guerra, Fabrizio; Polimeni, Antonella

    2013-01-01

    Even today, use of Glass Ionomer Cements (GIC) as restorative material is indicated for uncooperative patients. The study aimed at estimating the surface roughness of different GICs using or not their proprietary surface coatings and at observing the interfaces between cement and coating through SEM. Forty specimens have been obtained and divided into 4 groups: Fuji IX (IX), Fuji IX/G-Coat Plus (IXC), Vitremer (V), Vitremer/Finishing Gloss (VFG). Samples were obtained using silicone moulds to simulate class I restorations. All specimens were processed for profilometric evaluation. The statistical differences of surface roughness between groups were assessed using One-Way Analysis of Variance (One-Way ANOVA) (p<0.05). The Two-Way Analysis of Variance (Two-Way ANOVA) was used to evaluate the influence of two factors: restoration material and presence of coating. Coated restoration specimens (IXC and VFG) were sectioned perpendicular to the restoration surface and processed for SEM evaluation. No statistical differences in roughness could be noticed between groups or factors. Following microscopic observation, interfaces between restoration material and coating were better for group IXC than for group VFG. When specimens are obtained simulating normal clinical procedures, the presence of surface protection does not significantly improve the surface roughness of GICs.

  7. Dimensional Changes of Acrylic Resin Denture Bases: Conventional Versus Injection-Molding Technique

    PubMed Central

    Gharechahi, Jafar; Asadzadeh, Nafiseh; Shahabian, Foad; Gharechahi, Maryam

    2014-01-01

    Objective: Acrylic resin denture bases undergo dimensional changes during polymerization. Injection molding techniques are reported to reduce these changes and thereby improve physical properties of denture bases. The aim of this study was to compare dimensional changes of specimens processed by conventional and injection-molding techniques. Materials and Methods: SR-Ivocap Triplex Hot resin was used for conventional pressure-packed and SR-Ivocap High Impact was used for injection-molding techniques. After processing, all the specimens were stored in distilled water at room temperature until measured. For dimensional accuracy evaluation, measurements were recorded at 24-hour, 48-hour and 12-day intervals using a digital caliper with an accuracy of 0.01 mm. Statistical analysis was carried out by SPSS (SPSS Inc., Chicago, IL, USA) using t-test and repeated-measures ANOVA. Statistical significance was defined at P<0.05. Results: After each water storage period, the acrylic specimens produced by injection exhibited less dimensional changes compared to those produced by the conventional technique. Curing shrinkage was compensated by water sorption with an increase in water storage time decreasing dimensional changes. Conclusion: Within the limitations of this study, dimensional changes of acrylic resin specimens were influenced by the molding technique used and SR-Ivocap injection procedure exhibited higher dimensional accuracy compared to conventional molding. PMID:25584050

  8. Metallurgical and Mechanical Evaluation of 4340 Steel Produced by Direct Metal Laser Sintering

    NASA Astrophysics Data System (ADS)

    Jelis, Elias; Clemente, Matthew; Kerwien, Stacey; Ravindra, Nuggehalli M.; Hespos, Michael R.

    2015-03-01

    Direct metal laser sintering (DMLS) was used to produce high-strength low-alloy 4340 steel specimens. Mechanical and metallurgical analyses were performed on the specimens to determine the samples with the highest strengths and the least porosity. The optimal process parameters were thus defined based on the corresponding experimental conditions. Additionally, the effects of fabricating specimens with both virgin and recycled powders were studied. Scanning electron microscopy and electron-dispersive spectroscopy were performed on both types of powders to determine the starting morphology and composition. The initial tensile results are promising, suggesting that DMLS can produce specimens equal in strength to wrought materials. However, there is evidence of cracking on several of the heat-treated tensile specimens that is unexplained. Several theories point to disturbances in the build chamber environment that went undetected while the specimens were being fabricated.

  9. 3-D microstructure of olivine in complex geological materials reconstructed by correlative X-ray μ-CT and EBSD analyses.

    PubMed

    Kahl, W-A; Dilissen, N; Hidas, K; Garrido, C J; López-Sánchez-Vizcaíno, V; Román-Alpiste, M J

    2017-11-01

    We reconstruct the 3-D microstructure of centimetre-sized olivine crystals in rocks from the Almirez ultramafic massif (SE Spain) using combined X-ray micro computed tomography (μ-CT) and electron backscatter diffraction (EBSD). The semidestructive sample treatment involves geographically oriented drill pressing of rocks and preparation of oriented thin sections for EBSD from the μ-CT scanned cores. The μ-CT results show that the mean intercept length (MIL) analyses provide reliable information on the shape preferred orientation (SPO) of texturally different olivine groups. We show that statistical interpretation of crystal preferred orientation (CPO) and SPO of olivine becomes feasible because the highest densities of the distribution of main olivine crystal axes from EBSD are aligned with the three axes of the 3-D ellipsoid calculated from the MIL analyses from μ-CT. From EBSD data we distinguish multiple CPO groups and by locating the thin sections within the μ-CT volume, we assign SPO to the corresponding olivine crystal aggregates, which confirm the results of statistical comparison. We demonstrate that the limitations of both methods (i.e. no crystal orientation data in μ-CT and no spatial information in EBSD) can be overcome, and the 3-D orientation of the crystallographic axes of olivines from different orientation groups can be successfully correlated with the crystal shapes of representative olivine grains. Through this approach one can establish the link among geological structures, macrostructure, fabric and 3-D SPO-CPO relationship at the hand specimen scale even in complex, coarse-grained geomaterials. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  10. Identification of phlebotomine sand flies using one MALDI-TOF MS reference database and two mass spectrometer systems.

    PubMed

    Mathis, Alexander; Depaquit, Jérôme; Dvořák, Vit; Tuten, Holly; Bañuls, Anne-Laure; Halada, Petr; Zapata, Sonia; Lehrter, Véronique; Hlavačková, Kristýna; Prudhomme, Jorian; Volf, Petr; Sereno, Denis; Kaufmann, Christian; Pflüger, Valentin; Schaffner, Francis

    2015-05-10

    Rapid, accurate and high-throughput identification of vector arthropods is of paramount importance in surveillance programmes that are becoming more common due to the changing geographic occurrence and extent of many arthropod-borne diseases. Protein profiling by MALDI-TOF mass spectrometry fulfils these requirements for identification, and reference databases have recently been established for several vector taxa, mostly with specimens from laboratory colonies. We established and validated a reference database containing 20 phlebotomine sand fly (Diptera: Psychodidae, Phlebotominae) species by using specimens from colonies or field-collections that had been stored for various periods of time. Identical biomarker mass patterns ('superspectra') were obtained with colony- or field-derived specimens of the same species. In the validation study, high quality spectra (i.e. more than 30 evaluable masses) were obtained with all fresh insects from colonies, and with 55/59 insects deep-frozen (liquid nitrogen/-80 °C) for up to 25 years. In contrast, only 36/52 specimens stored in ethanol could be identified. This resulted in an overall sensitivity of 87 % (140/161); specificity was 100 %. Duration of storage impaired data counts in the high mass range, and thus cluster analyses of closely related specimens might reflect their storage conditions rather than phenotypic distinctness. A major drawback of MALDI-TOF MS is the restricted availability of in-house databases and the fact that mass spectrometers from 2 companies (Bruker, Shimadzu) are widely being used. We have analysed fingerprints of phlebotomine sand flies obtained by automatic routine procedure on a Bruker instrument by using our database and the software established on a Shimadzu system. The sensitivity with 312 specimens from 8 sand fly species from laboratory colonies when evaluating only high quality spectra was 98.3 %; the specificity was 100 %. The corresponding diagnostic values with 55 field-collected specimens from 4 species were 94.7 % and 97.4 %, respectively. A centralized high-quality database (created by expert taxonomists and experienced users of mass spectrometers) that is easily amenable to customer-oriented identification services is a highly desirable resource. As shown in the present work, spectra obtained from different specimens with different instruments can be analysed using a centralized database, which should be available in the near future via an online platform in a cost-efficient manner.

  11. Performance evaluation of the automated nucleated red blood cell enumeration on Sysmex XN analyser.

    PubMed

    Tantanate, C; Klinbua, C

    2015-06-01

    Presence of peripheral blood nucleated red blood cell (NRBC) is associated with pathological conditions and leads to the overestimation of white blood cell count in automated haematology analysers (HA). The authors evaluated NRBC enumeration by a new HA Sysmex XN (XN) to demonstrate the precision and comparability to manual count (MC) at the various NRBC values. Specimens with initially NRBC positive were included. For precision assessment, 8 levels of NRBCs were repeatedly analysed. For comparison study, 234 specimens were analysed by both XN and MC. For precision study, the percentage of coefficient of variation ranged from 14% to 45.6% and 1.2% to 4.4% for MC and XN, respectively. For comparison study between XN and MC, NRBCs ranged from 0% to 612.5%. Regression analysis demonstrated an r(2) of 0.98. The mean bias of 14.1% with 95% limits of agreement between -48.76% and 76.95% was found. The NRBC counts from XN appeared to be more in accordance with MC when the NRBCs were lower than 200% with the concordance rate of 94.2%. The automated NRBC enumeration by XN was precise and could replace the traditional MC, especially for the specimens with NRBCs lower than 200%. © 2014 John Wiley & Sons Ltd.

  12. A virtual reconstruction and comparative analysis of the KNM-ER 42700 cranium.

    PubMed

    Bauer, Catherine C; Harvati, Katerina

    2015-01-01

    The taxonomic attribution of the 1.55 million year old young adult fossil calvaria KNM-ER 42700   from Ileret, Kenya, is subject to ongoing controversy. It has been attributed to H. erectus based on comparative description and linear measurements. However, 3-D geometric morphometric analysis found that this specimen fell outside the range of variation of H. erectus in its cranial shape, which was intermediate between H. erectus and modern humans. One problem is that analyses so far were conducted on the original specimen, which shows slight post-mortem distortion. Here we use a surface scan of a high resolution cast of KNM-ER 42700 to virtually reconstruct the calvaria and conduct a new 3D geometric morphometric analysis of both its original and its reconstructed shape. Our comparative sample included several specimens of H. erectus (s.l., including the subadult KNM-WT 15000), H. habilis, H. heidelbergenis (s.l.) and H. neanderthalensis, as well as early and Upper Paleolithic H. sapiens. Our principal component analysis results showed that, like the original specimen, our virtual reconstruction of KNM-ER 42700 is also intermediate in shape between fossil Homo and modern humans. Taphonomic distortion, therefore, appears to not have been a major factor affecting previous 3-D geometric morphometric analyses. The intermediate shape of KNM-ER 42700 might instead be related to the young developmental age of the specimen. Further work on reconstructing the original specimen or based on computed tomorgraphic scans is needed to confirm these results.

  13. Flexural resistance of heat-pressed and CAD-CAM lithium disilicate with different translucencies.

    PubMed

    Fabian Fonzar, Riccardo; Carrabba, Michele; Sedda, Maurizio; Ferrari, Marco; Goracci, Cecilia; Vichi, Alessandro

    2017-01-01

    To compare flexural strength of CAD-CAM and heat-pressed lithium disilicate. For Pressed specimens (Group A), acrylate polymer blocks were cut with a saw in bars shape. Sprueing, investing and preheating procedures were carried out following manufacturer's instructions. IPS e.max Press ingots (Ivoclar-Vivadent) were divided into subgroups (n=15) according to translucency: A.1=HT-A3; A.2=MT-A3; A.3=LT-A3; A.4=MO2. Ingots were then pressed following manufacturer's instructions. For CAD-CAM specimens (Group B) blocks of IPS e.max CAD (Ivoclar-Vivadent) were divided into subgroups: B.1=HT-A3; B.2=MT-A3; B.3=LT-A3; B.4=MO2. Specimens (n=15) were obtained by cutting the blocks with a saw. Final crystallization was performed following manufacturer's instructions. Both Press and CAD specimens were polished and finished with silica carbide papers of increasing grit. Final dimensions of the specimens were 4.0±0.2mm, 1.2±0.2mm, and 16.0±0.2mm. Specimens were tested using a three-point bending test. Flexural strength, Weibull modulus, and Weibull characteristic strength were calculated. Flexural strength data were statistically analyzed. The overall means of Press and CAD specimens did not differ significantly. Within the Press group different translucencies were found to have similar flexural strength. Within the CAD group, statistically significant differences emerged among the tested translucencies (p<0.001). Specifically, MT had significantly higher flexural strength than HT and MO. Also, LT exhibited significantly higher flexural strength than MO. The choice between IPS e.max Press and IPS e.max CAD formulations can be based on different criteria than flexural resistance. Within each formulation, for IPS e.max Press translucency does not affect the flexural strength while for IPS e.max CAD it is an influential factor. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  14. Evaluation of the CDC proposed laboratory HIV testing algorithm among men who have sex with men (MSM) from five US metropolitan statistical areas using specimens collected in 2011.

    PubMed

    Masciotra, Silvina; Smith, Amanda J; Youngpairoj, Ae S; Sprinkle, Patrick; Miles, Isa; Sionean, Catlainn; Paz-Bailey, Gabriela; Johnson, Jeffrey A; Owen, S Michele

    2013-12-01

    Until recently most testing algorithms in the United States (US) utilized Western blot (WB) as the supplemental test. CDC has proposed an algorithm for HIV diagnosis which includes an initial screen with a Combo Antigen/Antibody 4th generation-immunoassay (IA), followed by an HIV-1/2 discriminatory IA of initially reactive-IA specimens. Discordant results in the proposed algorithm are resolved by nucleic acid-amplification testing (NAAT). Evaluate the results obtained with the CDC proposed laboratory-based algorithm using specimens from men who have sex with men (MSM) obtained in five metropolitan statistical areas (MSAs). Specimens from 992 MSM from five MSAs participating in the CDC's National HIV Behavioral Surveillance System in 2011 were tested at local facilities and CDC. The five MSAs utilized algorithms of various screening assays and specimen types, and WB as the supplemental test. At the CDC, serum/plasma specimens were screened with 4th generation-IA and the Multispot HIV-1/HIV-2 discriminatory assay was used as the supplemental test. NAAT was used to resolve discordant results and to further identify acute HIV infections from all screened-non-reactive missed by the proposed algorithm. Performance of the proposed algorithm was compared to site-specific WB-based algorithms. The proposed algorithm detected 254 infections. The WB-based algorithms detected 19 fewer infections; 4 by oral fluid (OF) rapid testing and 15 by WB supplemental testing (12 OF and 3 blood). One acute infection was identified by NAAT from all screened-non-reactive specimens. The proposed algorithm identified more infections than the WB-based algorithms in a high-risk MSM population. OF testing was associated with most of the discordant results between algorithms. HIV testing with the proposed algorithm can increase diagnosis of infected individuals, including early infections. Published by Elsevier B.V.

  15. Predicting fracture of mortar beams under three-point bending using non-extensive statistical modeling of electric emissions

    NASA Astrophysics Data System (ADS)

    Stergiopoulos, Ch.; Stavrakas, I.; Triantis, D.; Vallianatos, F.; Stonham, J.

    2015-02-01

    Weak electric signals termed as 'Pressure Stimulated Currents, PSC' are generated and detected while cement based materials are found under mechanical load, related to the creation of cracks and the consequent evolution of cracks' network in the bulk of the specimen. During the experiment a set of cement mortar beams of rectangular cross-section were subjected to Three-Point Bending (3PB). For each one of the specimens an abrupt mechanical load step was applied, increased from the low load level (Lo) to a high final value (Lh) , where Lh was different for each specimen and it was maintained constant for long time. The temporal behavior of the recorded PSC show that during the load increase a spike-like PSC emission was recorded and consequently a relaxation of the PSC, after reaching its final value, follows. The relaxation process of the PSC was studied using non-extensive statistical physics (NESP) based on Tsallis entropy equation. The behavior of the Tsallis q parameter was studied in relaxation PSCs in order to investigate its potential use as an index for monitoring the crack evolution process with a potential use in non-destructive laboratory testing of cement-based specimens of unknown internal damage level. The dependence of the q-parameter on the Lh (when Lh <0.8Lf), where Lf represents the 3PB strength of the specimen, shows an increase on the q value when the specimens are subjected to gradually higher bending loadings and reaches a maximum value close to 1.4 when the applied Lh becomes higher than 0.8Lf. While the applied Lh becomes higher than 0.9Lf the value of the q-parameter gradually decreases. This analysis of the experimental data manifests that the value of the entropic index q obtains a characteristic decrease while reaching the ultimate strength of the specimen, and thus could be used as a forerunner of the expected failure.

  16. Internal validation of STRmix™ for the interpretation of single source and mixed DNA profiles.

    PubMed

    Moretti, Tamyra R; Just, Rebecca S; Kehl, Susannah C; Willis, Leah E; Buckleton, John S; Bright, Jo-Anne; Taylor, Duncan A; Onorato, Anthony J

    2017-07-01

    The interpretation of DNA evidence can entail analysis of challenging STR typing results. Genotypes inferred from low quality or quantity specimens, or mixed DNA samples originating from multiple contributors, can result in weak or inconclusive match probabilities when a binary interpretation method and necessary thresholds (such as a stochastic threshold) are employed. Probabilistic genotyping approaches, such as fully continuous methods that incorporate empirically determined biological parameter models, enable usage of more of the profile information and reduce subjectivity in interpretation. As a result, software-based probabilistic analyses tend to produce more consistent and more informative results regarding potential contributors to DNA evidence. Studies to assess and internally validate the probabilistic genotyping software STRmix™ for casework usage at the Federal Bureau of Investigation Laboratory were conducted using lab-specific parameters and more than 300 single-source and mixed contributor profiles. Simulated forensic specimens, including constructed mixtures that included DNA from two to five donors across a broad range of template amounts and contributor proportions, were used to examine the sensitivity and specificity of the system via more than 60,000 tests comparing hundreds of known contributors and non-contributors to the specimens. Conditioned analyses, concurrent interpretation of amplification replicates, and application of an incorrect contributor number were also performed to further investigate software performance and probe the limitations of the system. In addition, the results from manual and probabilistic interpretation of both prepared and evidentiary mixtures were compared. The findings support that STRmix™ is sufficiently robust for implementation in forensic laboratories, offering numerous advantages over historical methods of DNA profile analysis and greater statistical power for the estimation of evidentiary weight, and can be used reliably in human identification testing. With few exceptions, likelihood ratio results reflected intuitively correct estimates of the weight of the genotype possibilities and known contributor genotypes. This comprehensive evaluation provides a model in accordance with SWGDAM recommendations for internal validation of a probabilistic genotyping system for DNA evidence interpretation. Copyright © 2017. Published by Elsevier B.V.

  17. The combined effects of prior-corrosion and aggressive chemical environments on fatigue crack growth behavior in aluminum alloy 7075-T651

    NASA Astrophysics Data System (ADS)

    Mills, Thomas Brian

    1997-11-01

    Exfoliation corrosion is a potentially severe form of corrosion that frequently affects high-strength aluminum, particularly 2xxx- and 7xxx-series alloys. Exfoliation degrades components such as sheets, plates, and extrusions that have highly elongated grain structures. Few attempts have been made to investigate the effects of this form of corrosion on the fatigue performance of these materials, so a preliminary study was conducted to determine the effects of exfoliation corrosion on the fatigue response of quarter-inch 7075-T651 aluminum alloy plate. This was accomplished by subjecting aluminum panels to an ASTM standard corrosive solution known as EXCO then fatiguing the panels in corrosion fatigue environments of dry air, humid air, and artificial acid rain. Statistical analyses of the fatigue crack growth data suggest that prior-corrosion and corrosion fatigue are competing mechanisms that both have the potential of accelerating crack growth rates. In the dry air cases, exfoliation accelerated crack growth rates a maximum of 4.75 times over the uncorroded material at lower stress intensities such as 5 ksi surdinch. This accelerated behavior dropped off rapidly, however, and was nonexistent at higher stress intensities. Humid air increased crack velocities considerably as compared to the dry air uncorroded case, but the addition of exfoliation corrosion to the humid cases did not have a significant effect on crack growth behavior. On the other hand, specimens containing exfoliation corrosion and then exposed to artificial acid rain had significantly higher crack growth rates than their uncorroded counterparts. Finally, fractographic examinations of the specimens revealed evidence of lower energy, quasi-cleavage fracture persisting near to the exfoliated edge of specimens tested in the dry air, humid air, and artificial acid rain environments. The implications of this research are that prior-corrosion damage has the ability to significantly increase crack growth rates in this material, and this could render unconservative the inspection intervals determined by damage tolerant analyses based on pristine, uncorroded structure in aircraft where this alloy and damage mechanism are present. The problem is further compounded in the event that prior-corrosion damage and corrosion fatigue act synergisticaliy to increase cracking rates.

  18. Damages detection in cylindrical metallic specimens by means of statistical baseline models and updated daily temperature profiles

    NASA Astrophysics Data System (ADS)

    Villamizar-Mejia, Rodolfo; Mujica-Delgado, Luis-Eduardo; Ruiz-Ordóñez, Magda-Liliana; Camacho-Navarro, Jhonatan; Moreno-Beltrán, Gustavo

    2017-05-01

    In previous works, damage detection of metallic specimens exposed to temperature changes has been achieved by using a statistical baseline model based on Principal Component Analysis (PCA), piezodiagnostics principle and taking into account temperature effect by augmenting the baseline model or by using several baseline models according to the current temperature. In this paper a new approach is presented, where damage detection is based in a new index that combine Q and T2 statistical indices with current temperature measurements. Experimental tests were achieved in a carbon-steel pipe of 1m length and 1.5 inches diameter, instrumented with piezodevices acting as actuators or sensors. A PCA baseline model was obtained to a temperature of 21º and then T2 and Q statistical indices were obtained for a 24h temperature profile. Also, mass adding at different points of pipe between sensor and actuator was used as damage. By using the combined index the temperature contribution can be separated and a better differentiation of damages respect to undamaged cases can be graphically obtained.

  19. Damage-Tolerance Characteristics of Composite Fuselage Sandwich Structures with Thick Facesheets

    NASA Technical Reports Server (NTRS)

    McGowan, David M.; Ambur, Damodar R.

    1997-01-01

    Damage tolerance characteristics and results from experimental and analytical studies of a composite fuselage keel sandwich structure subjected to low-speed impact damage and discrete-source damage are presented. The test specimens are constructed from graphite-epoxy skins borided to a honeycomb core, and they are representative of a highly loaded fuselage keel structure. Results of compression-after-impact (CAI) and notch-length sensitivity studies of 5-in.-wide by 10-in.long specimens are presented. A correlation between low-speed-impact dent depth, the associated damage area, and residual strength for different impact-energy levels is described; and a comparison of the strength for undamaged and damaged specimens with different notch-length-to-specimen-width ratios is presented. Surface strains in the facesheets of the undamaged specimens as well as surface strains that illustrate the load redistribution around the notch sites in the notched specimens are presented and compared with results from finite element analyses. Reductions in strength of as much as 53.1 percent for the impacted specimens and 64.7 percent for the notched specimens are observed.

  20. Test and evaluation of Apollo 14 composite casting demonstration specimens 6, 9, and 12, phase 1

    NASA Technical Reports Server (NTRS)

    Reger, J. L.

    1971-01-01

    Flight and control specimens 6, 9, and 12 from the Apollo 14 composite casting demonstration were evaluated with respect to the degree of dispersion achieved for mixtures of immiscible materials under one-gravity and low gravity environments. The flight and control capsules 6, 9, and 12 contained paraffin and sodium acetate; paraffin, sodium acetate and argon; and paraffin, sodium acetate and 100 micrometer diameter tungsten microspheres, respectively. The evaluation and documentation utilized photographic and microstructure examinations, density measurements, and droplet size and distribution determinations. In addition, theoretical analyses were performed in order to aid in the understanding of the fluid behavior of the specimens during processing and subsequent solidification. A comparison of evaluated data with the theoretical analyses reveals that although the immiscible materials were uniquely dispersed in a low gravity environment, nonuniform dispersions were obtained primarily due to insufficient initial mixing and an essentially unidirectional thermal gradient during cooldown.

  1. The influence of build parameters on the microstructure during electron beam melting of Titanium6Aluminum4Vanadium

    NASA Astrophysics Data System (ADS)

    Puebla, Karina

    With the demand of devices to replace or improve areas, such as: electronic, biomedical and aerospace industries. Improvements in these areas of engineering have been in need due to the customer's needs for product properties requirements. The design of components must exhibit better material properties (mechanical or biocompatible) close to those of any given product. Rapid prototyping (RP) technologies that were originally designed to build prototypes may now be required to build functional end-use products. To carry out the transition, from RP to rapid manufacturing (RM), the available materials utilized in RP must provide the performance required for RM. The specific technology being used should be capable of producing reliable parts in regards to their mechanical properties. The research presented in this work investigated the effects of building parameters (build orientation and melt scan rate) on microstructure and the mechanical properties of test specimens fabricated via Electron Beam Melting (EBM) using Ti6Al4V. EBM, a rapid prototyping technology, has the potential to manufacture complex 3-dimensional end-use products layer-by-layer. In this work, a design of experiments approach was performed to determine the effects of build orientation and melt scan rate on both the microstructure and mechanical properties of test samples fabricated using EBM. Two randomized setups were designed to build two batches of 18 specimens. The experimental designs were carried out to determine the effect of different build parameters (build orientation and melt scan rate) in the mechanical properties of the fabricated specimens. The results demonstrated that EBM manufactured specimens built with different melt scan rates and build orientations have different microstructures and mechanical properties. Different melt scans produced variations in particle sintering resulting in dissimilar porosities and in mechanical properties (hardness and tensile testing). The mechanical properties decreased as the porosity increased for tensile testing and Rockwell C-scale (HR C), while Vickers hardness (HV) measurements increased and are related to the microstructure. The different build orientations of the specimens produced different mechanical properties since the orientation of the fabricated specimens impact the local heat transfer flow. This influenced the microstructure where the specimens oriented horizontally cooled more rapidly than those built vertically. Statistically significant differences in mechanical properties were found as an effect of melt scan rate. The statistical analyses that were done can help identify and classify fabrication parameters on mechanical properties for EBM-fabricated products. Optical images demonstrated the presence of alpha and beta phases, and alpha'-martensite with slight differences in microstructure. Dislocation substructures were observed in acicular alpha-plates from TEM images and alpha, beta, and alpha'-phase features. Mechanical and thermal treatment on Ti6Al4V can generate different microstructures promoting Ti6Al4V as an evolutionary alloy. Tailored mechanical properties of complex 3-dimensional end-use products can be achieved by modifying the building parameters of the EBM system. The EBM system can facilitate the process of manufacturing components by varying build parameters in order to obtain desirable physical and mechanical properties. Once the desired properties for Ti6Al4V are established, the fabrication process will lead to more successful end-use products.

  2. An evaluation of the effects of handpiece speed, abrasive characteristics, and polishing load on the flexural strength of polished ceramics.

    PubMed

    Ahmad, Rohana; Morgano, Steven M; Wu, Benjamin M; Giordano, Russell A

    2005-11-01

    Many studies on the strengthening effects of grinding and polishing, as well as heat treatment on ceramics, are not well standardized or use commercially available industrial polishing systems. The reported effectiveness of these strengthening mechanisms on ceramics may not be applicable to clinical dentistry. The purpose of this study was to evaluate the effects of controlled polishing on the flexural strength of dental ceramics by using a custom-made machine that applied standardized loads and speeds that coincided with the mean loads and speeds used by experienced prosthodontists. A total of 140 aluminous dental ceramic bar-shaped specimens (Vitadur Alpha Enamel) measuring 1.5 x 2.0 x 25 mm were fabricated and divided into 12 groups (for most groups, n=10). Specimens were untreated, polished with different polishing systems, polished at different speeds, ground and autoglazed, polished and autoglazed, autoglazed and polished, polished with loose (paste) and bonded abrasives, or overglazed. Simulated clinical polishing was performed on the ceramic specimens by using a customized polishing apparatus that allowed independent control over the relevant polishing parameters (abrasive hardness, applied load, linear speed, rotational velocity, and wheel stiffness). Flexural strength (MPa) was measured with a 4-point bending test, and subjective surface roughness was assessed with scanning electron microscopy. Autoglazing was performed at various stages of the polishing sequence to determine the effects of polishing on surface stresses. Mean values, standard deviations, independent-sample t tests, 1-way and 2-way analyses of variance, Dunnett t tests and Kruskal-Wallis tests were applied to the data (alpha=.05). Under a clinical load of 0.6 N for a coarse polishing wheel, 1.0 N for a medium polishing wheel, and 1.3 N for a fine polishing wheel, a linear speed of 499 mm/min, and a rotational velocity of 10,000 rpm, the use of clinical polishing instruments did not affect the flexural strength of the aluminous ceramics studied (P=.274). At higher rotational velocity (20,000 rpm), specimens polished with the diamond polishing system produced statistically weaker specimens compared with those that had been polished at 10,000 rpm (P=.019). Autoglazing treatment of the diamond-polished specimens did not reverse the strength degradation (P=.125). Conversely, diamond polishing of the autoglazed specimens resulted in significant flexural strength reduction (P=.029). Fine-diamond-bonded abrasive significantly reduced flexural strength (P=.025). Simulated clinical polishing at 10,000 rpm did not appear to substantially strengthen or weaken the ceramic specimens. Polishing at 20,000 rpm reduced flexural strength of the ceramic bars.

  3. Effect of surface modifications on the bond strength of zirconia ceramic with resin cement resin.

    PubMed

    Hallmann, Lubica; Ulmer, Peter; Lehmann, Frank; Wille, Sebastian; Polonskyi, Oleksander; Johannes, Martina; Köbel, Stefan; Trottenberg, Thomas; Bornholdt, Sven; Haase, Fabian; Kersten, Holger; Kern, Matthias

    2016-05-01

    Purpose of this in vitro study was to evaluate the effect of surface modifications on the tensile bond strength between zirconia ceramic and resin. Zirconia ceramic surfaces were treated with 150-μm abrasive alumina particles, 150-μm abrasive zirconia particles, argon-ion bombardment, gas plasma, and piranha solution (H2SO4:H2O2=3:1). In addition, slip casting surfaces were examined. Untreated surfaces were used as the control group. Tensile bond strengths (TBS) were measured after water storage for 3 days or 150 days with additional 37,500 thermal cycling for artificial aging. Statistical analyses were performed with 1-way and 3-way ANOVA, followed by comparison of means with the Tukey HSD test. After storage in distilled water for three days at 37 °C, the highest mean tensile bond strengths (TBS) were observed for zirconia ceramic surfaces abraded with 150-μm abrasive alumina particles (TBS(AAP)=37.3 MPa, TBS(CAAP)=40.4 MPa), and 150-μm abrasive zirconia particles (TBS(AZP)=34.8 MPa, TBS(CAZP)=35.8 MPa). Also a high TBS was observed for specimens treated with argon-ion bombardment (TBS(BAI)=37.8 MPa). After 150 days of storage, specimens abraded with 150-μm abrasive alumina particles and 150-μm abrasive zirconia particles revealed high TBS (TBS(AAP)=37.6 MPa, TBS(CAAP)=33.0 MPa, TBS(AZP)=22.1 MPa and TBS(CAZP)=22.8 MPa). A high TBS was observed also for specimens prepared with slip casting (TBS(SC)=30.0 MPa). A decrease of TBS was observed for control specimens (TBS(UNT)=12.5 MPa, TBS(CUNT)=9.0 MPa), specimens treated with argon-ion bombardment (TBS(BAI)=10.3 MPa) and gas plasma (TBS(GP)=11.0 MPa). A decrease of TBS was observed also for specimens treated with piranha solution (TBS(PS)=3.9 MPa, TBS(CPS)=4.1 MPa). A significant difference in TBS after three days storage was observed for specimens treated with different methods (p<0.001). Thermal cycling significantly reduced TBS for all groups (p<0.001) excluding groups: AAP(p>0.05), CAAP(p>0.05) and SC(p>0.05). However, the failure patterns of debonded specimens prepared with 150-μm abrasive zirconia particles were 96.7% cohesive. Treatment of zirconia ceramic surfaces with abrasive zirconia particles is a promising method to increase the tensile bond strength without significant damage of the ceramic surface itself. An alternative promising method is slip casting. Copyright © 2016 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  4. Characterization of glass-infiltrated alumina-based ceramics

    PubMed Central

    Bona, Alvaro Della; Mecholsky, John J; Barrett, Allyson A; Griggs, Jason A

    2010-01-01

    Objective characterize the microstructure, composition, and important properties of glass-infiltrated alumina-based ceramics similar to the In-Ceram system. Methods Materials used were: IA- In-Ceram Alumina (Vita); IAE- IA electrophoretically deposited (Vita); AEM- IA using a vacuum driven method (Vita); VC- Vitro-Ceram (Angelus); TC- Turkom-Cera (Turkom-Ceramic); CC- Ceramcap (Foto-Ceram); and AG- Alglass (EDG). Ceramic specimens were fabricated following manufacturers’ instructions and ISO6872 standard and polished successively through 1μm alumina abrasive. Semi-quantitative and qualitative analyses were performed using scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and stereology (Vv). The elastic modulus (E) and Poisson’s ratio (ν) were determined using time-of-flight data measured in an ultrasonic pulser/receiver and the density (ρ) was determined using a helium pycnometer. Vicker’s indentation was used to calculate hardness (H). Bar specimens (25×4×1.2mm3) were loaded in three-point bending to fracture using a universal testing machine with cross-head speed of 1mm/min. Flexural strength (σ3P) was calculated and statistically analyzed using ANOVA, Tukey (α=0.05) and Weibull (m= modulus, σ0= characteristic strength). Results SEM and EDS analyses revealed similar microstructure for all ceramics, except for a lead-based matrix in CC and a zirconia phase in VC. TC, AG and CC showed significantly lower mean σ3P values than the other ceramics (p 0.05). AEM showed the greatest m (16). Conclusion Despite few differences in microstructure and composition, the IA, IAE, AEM and VC ceramics have similar properties. Significance The glass-infiltrated alumina-based ceramics from different manufacturers presented distinct characteristics. It is necessary to characterize new commercially available materials to understand their properties. PMID:18692231

  5. Experimental strength of restorations with fibre posts at different stages, with and without using a simulated ligament.

    PubMed

    Pérez-González, A; González-Lluch, C; Sancho-Bru, J L; Rodríguez-Cervantes, P J; Barjau-Escribano, A; Forner-Navarro, L

    2012-03-01

    The aim of this study was to analyse the strength and failure mode of teeth restored with fibre posts under retention and flexural-compressive loads at different stages of the restoration and to analyse whether including a simulated ligament in the experimental setup has any effect on the strength or the failure mode. Thirty human maxillary central incisors were distributed in three different groups to be restored with simulation of different restoration stages (1: only post, 2: post and core, 3: post-core and crown), using Rebilda fibre posts. The specimens were inserted in resin blocks and loaded by means of a universal testing machine until failure under tension (stage 1) and 50º flexion (stages 2-3). Half the specimens in each group were restored using a simulated ligament between root dentine and resin block and the other half did not use this element. Failure in stage 1 always occurred at the post-dentine interface, with a mean failure load of 191·2 N. Failure in stage 2 was located mainly in the core or coronal dentine (mean failure load of 505·9 N). Failure in stage 3 was observed in the coronal dentine (mean failure load 397·4 N). Failure loads registered were greater than expected masticatory loads. Fracture modes were mostly reparable, thus indicating that this post is clinically valid at the different stages of restoration studied. The inclusion of the simulated ligament in the experimental system did not show a statistically significant effect on the failure load or the failure mode. © 2011 Blackwell Publishing Ltd.

  6. Human fecal flora: variation in bacterial composition within individuals and a possible effect of emotional stress.

    PubMed Central

    Holdeman, L V; Good, I J; Moore, W E

    1976-01-01

    Data are presented on the distribution of 101 bacterial species and subspecies among 1,442 isolates from 25 fecal specimens from three men on: (i) their normal diet and normal living conditions, (ii) normal living conditions but eating the controlled metabolic diet designed for use in the Skylab simulation and missions, and (iii) the Skylab diet in simulated Skylab (isolation) conditions. These bacteria represent the most numerous kinds in the fecal flora. Analyses of the kinds of bacteria from each astronaut during the 5-month period showed more variation in the composition of the flora among the individual astronauts than among the eight or nine samples from each person. This observation indicates that the variations in fecal flora reported previously, but based on the study of only one specimen from each person, more certainly reflect real differences (and not daily variation) in the types of bacteria maintained by individual people. The proportions of the predominant fecal species in the astronauts were similar to those reported earlier from a Japanese-Hawaiian population and were generally insensitive to changes from the normal North American diet to the Skylab diet; only two of the most common species were affected by changes in diet. However, one of the predominant species (Bacteroides fragilis subsp. thetaiotaomicron) appeared to be affected during confinement of the men in the Skylab test chamber. Evidence is presented suggesting that an anger stress situation may have been responsible for the increase of this species simultaneously in all of the subjects studied. Phenotypic characteristics of some of the less common isolates are given. The statistical analyses used in interpretation of the results are discussed. PMID:938032

  7. Changes in haematology measurements with the Sysmex XT-2000iV during storage of feline blood sampled in EDTA or EDTA plus CTAD.

    PubMed

    Granat, Fanny; Geffré, Anne; Bourgès-Abella, Nathalie; Braun, Jean-Pierre; Trumel, Catherine

    2013-06-01

    In veterinary medicine a complete blood cell count (CBC) cannot always be performed within 24 h as usually recommended, particularly for specimens shipped to a reference laboratory. This raises the question of the stability of the variables, especially in ethylenediamine tetra-acetic acid (EDTA) feline blood specimens, known to be prone to in vitro platelet aggregation. Citrate, theophylline, adenosine and dipyridamole (CTAD) has been reported to limit platelet aggregation in feline blood specimens. The aim of this study was to measure the stability of the haematological variables and the platelet aggregation score in EDTA and EDTA plus CTAD (EDCT) feline blood specimens during 48 h of storage at room temperature. Forty-six feline EDTA and EDCT blood specimens were analysed with a Sysmex XT-2000iV analyser, and the platelet count and score of platelet aggregation were estimated immediately and after 24 and 48 h of storage. A significant increase in mean corpuscular volume, haematocrit, reticulocyte and eosinophil counts, and a significant decrease in mean corpuscular haemoglobin concentration and monocyte count were observed. Haemoglobin, mean corpuscular haemoglobin, and red blood cell, white blood cell, neutrophil and lymphocyte counts remained stable. Changes in reticulocyte indexes with time (low fluorescence ratio, medium fluorescence ratio, high fluorescence ratio and immature reticulocyte fraction) were not significant. Changes were generally more pronounced in EDTA than in EDCT. Platelet aggregation decreased markedly in initially highly aggregated EDTA specimens, and increased slightly in initially non- or mildly-aggregated EDTA or EDCT specimens. Platelet counts increased and decreased, or remained stable, respectively. CTAD can reduce storage-induced changes of the haematological variables in feline samples, thus improving the reliability of a CBC and limiting clinical misinterpretations.

  8. From museums to genomics: old herbarium specimens shed light on a C3 to C4 transition.

    PubMed

    Besnard, Guillaume; Christin, Pascal-Antoine; Malé, Pierre-Jean G; Lhuillier, Emeline; Lauzeral, Christine; Coissac, Eric; Vorontsova, Maria S

    2014-12-01

    Collections of specimens held by natural history museums are invaluable material for biodiversity inventory and evolutionary studies, with specimens accumulated over 300 years readily available for sampling. Unfortunately, most museum specimens yield low-quality DNA. Recent advances in sequencing technologies, so called next-generation sequencing, are revolutionizing phylogenetic investigations at a deep level. Here, the Illumina technology (HiSeq) was used on herbarium specimens of Sartidia (subfamily Aristidoideae, Poaceae), a small African-Malagasy grass lineage (six species) characteristic of wooded savannas, which is the C3 sister group of Stipagrostis, an important C4 genus from Africa and SW Asia. Complete chloroplast and nuclear ribosomal sequences were assembled for two Sartidia species, one of which (S. perrieri) is only known from a single specimen collected in Madagascar 100 years ago. Partial sequences of a few single-copy genes encoding phosphoenolpyruvate carboxylases (ppc) and malic enzymes (nadpme) were also assembled. Based on these data, the phylogenetic position of Malagasy Sartidia in the subfamily Aristidoideae was investigated and the biogeographical history of this genus was analysed with full species sampling. The evolutionary history of two genes for C4 photosynthesis (ppc-aL1b and nadpme-IV) in the group was also investigated. The gene encoding the C4 phosphoenolpyruvate caroxylase of Stipagrostis is absent from S. dewinteri suggesting that it is not essential in C3 members of the group, which might have favoured its recruitment into a new metabolic pathway. Altogether, the inclusion of historical museum specimens in phylogenomic analyses of biodiversity opens new avenues for evolutionary studies. © The Author 2014. Published by Oxford University Press on behalf of the Society for Experimental Biology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  9. Bone marrow necrosis related to paracoccidioidomycosis: the first eight cases identified at autopsy

    PubMed Central

    Resende, Lucilene S R; Mendes, Rinaldo P; Bacchi, Maura M; Marques, Sílvio A; Barraviera, Benedito; Souza, Lenice R; Meira, Domingos A; Niéro-Melo, Lígia

    2009-01-01

    Aims: To report the first eight bone marrow necrosis (BMN) cases related to paracoccidioidomycosis (PCM) from patient autopsies with well-documented bone marrow (BM) histology and cytology. Methods and results: A retrospective evaluation was performed on BM specimens from eight autopsied patients from Botucatu University Hospital with PCM-related BMN. Relevant BMN literature was searched and analysed. Conclusions: All eight patients had acute PCM. Six had histological only (biopsies) and two cytological only (smears) specimens. Five biopsy specimens revealed severe and one mild coagulation patterned necrotic areas. Five had osteonecrosis. The cytological specimens also showed typical BMN patterns. Paracoccidioides brasiliensis yeast forms were visible within necrotic areas in all cases. PMID:19309401

  10. The detection of tightly closed flaws by nondestructive testing (NDT) methods. [fatigue crack formation in aluminum alloy test specimens

    NASA Technical Reports Server (NTRS)

    Rummel, W. D.; Rathke, R. A.; Todd, P. H., Jr.; Mullen, S. J.

    1975-01-01

    Liquid penetrant, ultrasonic, eddy current and X-radiographic techniques were optimized and applied to the evaluation of 2219-T87 aluminum alloy test specimens in integrally stiffened panel, and weld panel configurations. Fatigue cracks in integrally stiffened panels, lack-of-fusion in weld panels, and fatigue cracks in weld panels were the flaw types used for evaluation. A 2319 aluminum alloy weld filler rod was used for all welding to produce the test specimens. Forty seven integrally stiffened panels containing a total of 146 fatigue cracks, ninety three lack-of-penetration (LOP) specimens containing a total of 239 LOP flaws, and one-hundred seventeen welded specimens containing a total of 293 fatigue cracks were evaluated. Nondestructive test detection reliability enhancement was evaluated during separate inspection sequences in the specimens in the 'as-machined or as-welded', post etched and post proof loaded conditions. Results of the nondestructive test evaluations were compared to the actual flaw size obtained by measurement of the fracture specimens after completing all inspection sequences. Inspection data were then analyzed to provide a statistical basis for determining the flaw detection reliability.

  11. Influence of ceramic surface texture on the wear of gold alloy and heat-pressed ceramics.

    PubMed

    Saiki, Osamu; Koizumi, Hiroyasu; Nogawa, Hiroshi; Hiraba, Haruto; Akazawa, Nobutaka; Matsumura, Hideo

    2014-01-01

    The purpose of this study was to evaluate the influence of ceramic surface texture on the wear of rounded rod specimens. Plate specimens were fabricated from zirconia (ZrO2), feldspathic porcelain, and lithium disilicate glass ceramics (LDG ceramics). Plate surfaces were either ground or polished. Rounded rod specimens with a 2.0-mm-diameter were fabricated from type 4 gold alloy and heat-pressed ceramics (HP ceramics). Wear testing was performed by means of a wear testing apparatus under 5,000 reciprocal strokes of the rod specimen with 5.9 N vertical loading. The results were statistically analyzed with a non-parametric procedure. The gold alloy showed the maximal height loss (90.0 µm) when the rod specimen was abraded with ground porcelain, whereas the HP ceramics exhibited maximal height loss (49.8 µm) when the rod specimen was abraded with ground zirconia. There was a strong correlation between height loss of the rod and surface roughness of the underlying plates, for both the gold alloy and HP ceramics.

  12. Mechanical strength of laser-welded cobalt-chromium alloy.

    PubMed

    Baba, N; Watanabe, I; Liu, J; Atsuta, M

    2004-05-15

    The purpose of this study was to investigate the effect of the output energy of laser welding and welding methods on the joint strength of cobalt-chromium (Co-Cr) alloy. Two types of cast Co-Cr plates were prepared, and transverse sections were made at the center of the plate. The cut surfaces were butted against one another, and the joints welded with a laser-welding machine at several levels of output energy with the use of two methods. The fracture force required to break specimens was determined by means of tensile testing. For the 0.5-mm-thick specimens, the force required to break the 0.5-mm laser-welded specimens at currents of 270 and 300 A was not statistically different (p > 0.05) from the results for the nonwelded control specimens. The force required to break the 1.0-mm specimens double-welded at a current of 270 A was the highest value among the 1.0-mm laser-welded specimens. The results suggested that laser welding under the appropriate conditions improved the joint strength of cobalt- chromium alloy. Copyright 2004 Wiley Periodicals, Inc.

  13. Experimental and statistical study on fracture boundary of non-irradiated Zircaloy-4 cladding tube under LOCA conditions

    NASA Astrophysics Data System (ADS)

    Narukawa, Takafumi; Yamaguchi, Akira; Jang, Sunghyon; Amaya, Masaki

    2018-02-01

    For estimating fracture probability of fuel cladding tube under loss-of-coolant accident conditions of light-water-reactors, laboratory-scale integral thermal shock tests were conducted on non-irradiated Zircaloy-4 cladding tube specimens. Then, the obtained binary data with respect to fracture or non-fracture of the cladding tube specimen were analyzed statistically. A method to obtain the fracture probability curve as a function of equivalent cladding reacted (ECR) was proposed using Bayesian inference for generalized linear models: probit, logit, and log-probit models. Then, model selection was performed in terms of physical characteristics and information criteria, a widely applicable information criterion and a widely applicable Bayesian information criterion. As a result, it was clarified that the log-probit model was the best among the three models to estimate the fracture probability in terms of the degree of prediction accuracy for both next data to be obtained and the true model. Using the log-probit model, it was shown that 20% ECR corresponded to a 5% probability level with a 95% confidence of fracture of the cladding tube specimens.

  14. Characterization of ABS specimens produced via the 3D printing technology for drone structural components

    NASA Astrophysics Data System (ADS)

    Ferro, Carlo Giovanni; Brischetto, Salvatore; Torre, Roberto; Maggiore, Paolo

    2016-07-01

    The Fused Deposition Modelling (FDM) technology is widely used in rapid prototyping. 3D printers for home desktop applications are usually employed to make non-structural objects. When the mechanical stresses are not excessive, this technology can also be successfully employed to produce structural objects, not only in prototyping stage but also in the realization of series pieces. The innovative idea of the present work is the application of this technology, implemented in a desktop 3D printer, to the realization of components for aeronautical use, especially for unmanned aerial systems. For this purpose, the paper is devoted to the statistical study of the performance of a desktop 3D printer to understand how the process performs and which are the boundary limits of acceptance. Mechanical and geometrical properties of ABS (Acrylonitrile Butadiene Styrene) specimens, such as tensile strength and stiffness, have been evaluated. ASTM638 type specimens have been used. A capability analysis has been applied for both mechanical and dimensional performances. Statistically stable limits have been determined using experimentally collected data.

  15. Residual stress in glass: indentation crack and fractography approaches.

    PubMed

    Anunmana, Chuchai; Anusavice, Kenneth J; Mecholsky, John J

    2009-11-01

    To test the hypothesis that the indentation crack technique can determine surface residual stresses that are not statistically significantly different from those determined from the analytical procedure using surface cracks, the four-point flexure test, and fracture surface analysis. Soda-lime-silica glass bar specimens (4 mm x 2.3 mm x 28 mm) were prepared and annealed at 650 degrees C for 30 min before testing. The fracture toughness values of the glass bars were determined from 12 specimens based on induced surface cracks, four-point flexure, and fractographic analysis. To determine the residual stress from the indentation technique, 18 specimens were indented under 19.6N load using a Vickers microhardness indenter. Crack lengths were measured within 1 min and 24h after indentation, and the measured crack lengths were compared with the mean crack lengths of annealed specimens. Residual stress was calculated from an equation developed for the indentation technique. All specimens were fractured in a four-point flexure fixture and the residual stress was calculated from the strength and measured crack sizes on the fracture surfaces. The results show that there was no significant difference between the residual stresses calculated from the two techniques. However, the differences in mean residual stresses calculated within 1 min compared with those calculated after 24h were statistically significant (p=0.003). This study compared the indentation technique with the fractographic analysis method for determining the residual stress in the surface of soda-lime-silica glass. The indentation method may be useful for estimating residual stress in glass.

  16. Residual stress in glass: indentation crack and fractography approaches

    PubMed Central

    Anunmana, Chuchai; Anusavice, Kenneth J.; Mecholsky, John J.

    2009-01-01

    Objective To test the hypothesis that the indentation crack technique can determine surface residual stresses that are not statistically significantly different from those determined from the analytical procedure using surface cracks, the four-point flexure test, and fracture surface analysis. Methods Soda-lime-silica glass bar specimens (4 mm × 2.3 mm × 28 mm) were prepared and annealed at 650 °C for 30 min before testing. The fracture toughness values of the glass bars were determined from 12 specimens based on induced surface cracks, four-point flexure, and fractographic analysis. To determine the residual stress from the indentation technique, 18 specimens were indented under 19.6 N load using a Vickers microhardness indenter. Crack lengths were measured within 1 min and 24 h after indentation, and the measured crack lengths were compared with the mean crack lengths of annealed specimens. Residual stress was calculated from an equation developed for the indentation technique. All specimens were fractured in a four-point flexure fixture and the residual stress was calculated from the strength and measured crack sizes on the fracture surfaces. Results The results show that there was no significant difference between the residual stresses calculated from the two techniques. However, the differences in mean residual stresses calculated within 1 min compared with those calculated after 24 h were statistically significant (p=0.003). Significance This study compared the indentation technique with the fractographic analysis method for determining the residual stress in the surface of soda-lime silica glass. The indentation method may be useful for estimating residual stress in glass. PMID:19671475

  17. Effect of tray-based and trayless tooth whitening systems on microhardness of enamel surface and subsurface.

    PubMed

    Teixeira, Erica C N; Ritter, André V; Thompson, Jeffrey Y; Leonard, Ralph H; Swift, Edward J

    2004-12-01

    To evaluate the effect of tray-based and trayless tooth whitening systems on surface and subsurface microhardness of human enamel. Enamel slabs were obtained from recently extracted human third molars. Specimens were randomly assigned to six groups according to tooth whitening treatment (n = 10): 6.0% hydrogen peroxide (HP) (Crest Whitestrips), 6.5% HP (Crest Professional Whitestrips), 7.5% HP (Day White Excel 3), 9.5% HP (Day White Excel 3), 10% carbamide peroxide (Opalescence), and a control group (untreated). Specimens were treated for 14 days following manufacturers' recommended protocols, and were immersed in artificial saliva between treatments. Enamel surface Knoop microhardness (KHN) was measured immediately before treatment, and at days 1, 7, and 14 of treatment. After treatment, subsurface microhardness was measured at depths of 50-500 microm. Data were analyzed for statistical significance using analysis of variance. Differences in microhardness for treated vs. untreated enamel surface were not statistically significant at any time interval. For 6.5% and 9.5% HP, there was a decrease in surface microhardness values during treatment, but at the end of treatment the microhardness values were not statistically different from the baseline values. For the enamel subsurface values, no differences were observed between treated vs. untreated specimens at each depth. Trayless and tray-based tooth whitening treatments do not significantly affect surface or subsurface enamel microhardness.

  18. Characterization of Cement Particles Found in Peri-implantitis-Affected Human Biopsy Specimens.

    PubMed

    Burbano, Maria; Wilson, Thomas G; Valderrama, Pilar; Blansett, Jonathan; Wadhwani, Chandur P K; Choudhary, Pankaj K; Rodriguez, Lucas C; Rodrigues, Danieli C

    2015-01-01

    Peri-implantitis is a disease characterized by soft tissue inflammation and continued loss of supporting bone, which can result in implant failure. Peri-implantitis is a multifactorial disease, and one of its triggering factors may be the presence of excess cement in the soft tissues surrounding an implant. This descriptive study evaluated the composition of foreign particles from 36 human biopsy specimens with 19 specimens selected for analysis. The biopsy specimens were obtained from soft tissues affected by peri-implantitis around cement-retained implant crowns and compared with the elemental composition of commercial luting cement. Nineteen biopsy specimens were chosen for the comparison, and five test cements (TempBond, Telio, Premier Implant Cement, Intermediate Restorative Material, and Relyx) were analyzed using scanning electron microscopy equipped with energy dispersive x-ray spectroscopy. This enabled the identification of the chemical composition of foreign particles embedded in the tissue specimens and the composition of the five cements. Statistical analysis was conducted using classification trees to pair the particles present in each specimen with the known cements. The particles in each biopsy specimen could be associated with one of the commercial cements with a level of probability ranging between .79 and 1. TempBond particles were found in one biopsy specimen, Telio particles in seven, Premier Implant Cement particles in four, Relyx particles in four, and Intermediate Restorative Material particles in three. Particles found in human soft tissue biopsy specimens around implants affected by peri-implant disease were associated with five commercially available dental cements.

  19. Effects of preparation relief and flow channels on seating full coverage castings during cementation.

    PubMed

    Webb, E L; Murray, H V; Holland, G A; Taylor, D F

    1983-06-01

    Machined steel dies were used to study the effects of three die modifications on seating full coverage castings during cementation. The die modifications consisted of occlusal channels, occlusal surface relief, and axial channels. Fourteen specimens having one or more forms of die modification were compared with two control specimens having no die modifications. Statistical analysis of the data revealed that the addition of four axial channels to the simulated preparation on the steel die produced a significant reduction in the mean marginal discrepancy during cementation. Occlusal modifications alone failed to produce significant reductions in marginal discrepancies when compared with the control specimens. Occlusal modifications in conjunction with axial channels failed to produce further significant reductions in marginal discrepancies when compared with those reductions observed in specimens having only axial channels.

  20. Variations of a global constraint factor in cracked bodies under tension and bending loads

    NASA Technical Reports Server (NTRS)

    Newman, J. C., Jr.; Crews, J. H., Jr.; Bigelow, C. A.; Dawicke, D. S.

    1994-01-01

    Elastic-plastic finite-element analyses were used to calculate stresses and displacements around a crack in finite-thickness plates for an elastic-perfectly plastic material. Middle- and edge-crack specimens were analyzed under tension and bending loads. Specimens were 1.25 to 20 mm thick with various widths and crack lengths. A global constraint factor alpha(sub g), an averaged normal-stress to flow-stress ratio over the plastic region, was defined to simulate three-dimensional (3D) effects in two-dimensional (2D) models. For crack lengths and uncracked ligament lengths greater than four times the thickness, the global constraint factor was found to be nearly a unique function of a normalized stress-intensity factor (related to plastic-zone size to thickness ratio) from small- to large-scale yielding conditions for various specimen types and thickness. For crack length-to-thickness ratios less than four, the global constraint factor was specimen type, crack length and thickness dependent. Using a 2D strip-yield model and the global constraint factors, plastic-zone sizes and crack-tip displacements agreed reasonably well with the 3D analyses. For a thin sheet aluminum alloy, the critical crack-tip-opening angle during stable tearing was found to be independent of specimen type and crack length for crack length-to-thickness ratios greater than 4.

  1. Analysis of the microRNA transcriptome of Daphnia pulex during aging.

    PubMed

    Hu, Jiabao; Lin, Chongyuan; Liu, Mengdi; Tong, Qiaoqiong; Xu, Shanliang; Wang, Danli; Zhao, Yunlong

    2018-07-20

    Daphnia pulex is an important food organism that exhibits a particular mode of reproduction known as cyclical parthenogenesis (asexual) and sexual reproduction. Regulation of the aging process by microRNAs (miRNAs) is a research hotspot in miRNA studies. To investigate a possible role of miRNAs in regulating aging and senescence, we used Illumina HiSeq to sequence two miRNA libraries from 1-day-old (1d) and 25-day-old (25d) D. pulex specimens. In total, we obtained 11,218,097 clean reads and 28,569 unique miRNAs from 1d specimens and 11,819,106 clean reads and 44,709 unique miRNAs from 25d specimens. Bioinformatic analyses was used to identify 1335 differentially expressed miRNAs from known miRNAs, including 127 miRNAs that exhibited statistically significant differences (P < 0.01); 92 miRNAs were upregulated and 35 were downregulated. Quantitative real-time (qRT)-PCR experiments were performed for nine miRNAs from five samples (1d, 5d, 10d, 15d, 20d and 25d) during the aging process, and the sequencing and qRT-PCR data were found to be consistent. Ninety-four miRNAs were predicted to correspond to 2014 target genes in known miRNAs with 4032 target gene sites. Sixteen pathways changed significantly (P < 0.05) at different developmental stages, revealing many important principles of the miRNA regulatory aging network of D. pulex. Overall, the difference in miRNA expression profile during aging of D. pulex forms a basis for further studies aimed at understanding the role of miRNAs in regulating aging, reproductive transformation, senescence, and longevity. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. T2* mapping of hip joint cartilage in various histological grades of degeneration.

    PubMed

    Bittersohl, B; Miese, F R; Hosalkar, H S; Herten, M; Antoch, G; Krauspe, R; Zilkens, C

    2012-07-01

    To evaluate T2* values in various histological severities of osteoarthritis (OA). Magnetic resonance imaging (MRI) and T2* mapping including a three-dimensional (3D) double-echo steady-state (DESS) sequence for morphological cartilage assessment and a 3D multiecho data image combination (MEDIC) sequence for T2* mapping were conducted in 21 human femoral head specimens with varying severities of OA. Subsequently, histological assessment was undertaken in all specimens to correlate the observations of T2* mapping with histological analyses. According to the Mankin score, four grades of histological changes were determined: grade 0 (Mankin scores of 0-4), grade I (scores of 5-8), grade II (scores of 9-10), and grade III (scores of 11-14). For reliability assessment, cartilage T2* measurements were repeated after 4 weeks in 10 randomly selected femoral head specimens. T2* values decreased significantly with increasing cartilage degeneration (total P-values <0.001) ranging from 36.3 ± 4.3 ms in grade 0 regions to 22.8 ± 4.3 ms in regions with grade III changes. Pearson correlation analysis proved a fair correlation between T2* values and Mankin score (correlation coefficient = -0.362) that was statistically significant (P-value <0.001). Intra-class correlation (ICC) analysis demonstrated high intra-observer reproducibility for the T2* measurement (ICC: 0.949, P < 0.001). Given the advantages of the T2* mapping technique with no need for contrast medium, high image resolution and ability to perform 3D biochemically sensitive imaging, T2* mapping may be a strong addition to the currently evolving era of cartilage biochemical imaging. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  3. Effect of Er:YAG laser irradiation on bonding property of zirconia ceramics to resin cement.

    PubMed

    Lin, Yihua; Song, Xiaomeng; Chen, Yaming; Zhu, Qingping; Zhang, Wei

    2013-12-01

    This study aimed to investigate whether or not an erbium: yttrium-aluminum-garnet (Er:YAG) laser could improve the bonding property of zirconia ceramics to resin cement. Surface treatments can improve the bonding properties of dental ceramics. However, little is known about the effect of Er:YAG laser irradiated on zirconia ceramics. Specimens of zirconia ceramic pieces were made, and randomly divided into 11 groups according to surface treatments, including one control group (no treatment), one air abrasion group, and nine Er:YAG laser groups. The laser groups were subdivided by applying different energy intensities (100, 200, or 300 mJ) and irradiation times (5, 10, or 15 sec). After surface treatments, ceramic pieces had their surface morphology observed, and their surface roughness was measured. All specimens were bonded to resin cement. Shear bond strength was measured after the bonded specimens were stored in water for 24 h, and additionally aged by thermocycling. Statistical analyses were performed using one way analysis of variance (ANOVA) and Tukey's test for shear bond strength, and Dunnett's t test for surface roughness, with α=0.05. Er:YAG laser irradiation changed the morphological characteristics of zirconia ceramics. Higher energy intensities (200, 300 mJ) could roughen the ceramics, but also caused surface cracks. There were no significant differences in the bond strength between the control group and the laser groups treated with different energy intensities or irradiation times. Air abrasion with alumina particles induced highest surface roughness and shear bond strength. Er:YAG laser irradiation cannot improve the bonding property of zirconia ceramics to resin cement. Enhancing irradiation intensities and extending irradiation time have no benefit on the bond of the ceramics, and might cause material defect.

  4. A novel expert system for objective masticatory efficiency assessment

    PubMed Central

    2018-01-01

    Most of the tools and diagnosis models of Masticatory Efficiency (ME) are not well documented or severely limited to simple image processing approaches. This study presents a novel expert system for ME assessment based on automatic recognition of mixture patterns of masticated two-coloured chewing gums using a combination of computational intelligence and image processing techniques. The hypotheses tested were that the proposed system could accurately relate specimens to the number of chewing cycles, and that it could identify differences between the mixture patterns of edentulous individuals prior and after complete denture treatment. This study enrolled 80 fully-dentate adults (41 females and 39 males, 25 ± 5 years of age) as the reference population; and 40 edentulous adults (21 females and 19 males, 72 ± 8.9 years of age) for the testing group. The system was calibrated using the features extracted from 400 samples covering 0, 10, 15, and 20 chewing cycles. The calibrated system was used to automatically analyse and classify a set of 160 specimens retrieved from individuals in the testing group in two appointments. The ME was then computed as the predicted number of chewing strokes that a healthy reference individual would need to achieve a similar degree of mixture measured against the real number of cycles applied to the specimen. The trained classifier obtained a Mathews Correlation Coefficient score of 0.97. ME measurements showed almost perfect agreement considering pre- and post-treatment appointments separately (κ ≥ 0.95). Wilcoxon signed-rank test showed that a complete denture treatment for edentulous patients elicited a statistically significant increase in the ME measurements (Z = -2.31, p < 0.01). We conclude that the proposed expert system proved able and reliable to accurately identify patterns in mixture and provided useful ME measurements. PMID:29385165

  5. The effect of MTAD, an endodontic irrigant, on fibroblast attachment to periodontally affected root surfaces: A SEM analysis

    PubMed Central

    Ghandi, Mostafa; Houshmand, Behzad; Nekoofar, Mohammad H.; Tabor, Rachel K.; Yadeghari, Zahra; Dummer, Paul M. H.

    2013-01-01

    Background: Root surface debridement (RSD) is necessary to create an environment suitable for reattachment of the periodontium. Root surface conditioning may aid the formation of a biocompatible surface suitable for cell reattachment. BioPure™ MTAD (mixture of Doxycycline, citric acid and a detergent) is an endodontic irrigant with antibacterial properties and the ability to remove smear layer. It was hypothesized that MTAD may be useful for root surface conditioning. The efficacy of MTAD as a conditioner was measured by examining fibroblast attachment to root surfaces. Materials and Methods: Thirty-two specimens of human teeth with advanced periodontal disease were used. The surfaces were root planed until smooth. Half of the specimens were treated with 0.9% saline and the other samples with Biopure MTAD. As a negative control group, five further samples were left unscaled with surface calculus. Human gingival fibroblast cells HGF1-PI1 were cultured and poured over the tooth specimens and incubated. After fixation, the samples were sputter-coated with gold and examined with a SEM. The morphology and number of attached, fixed viable cells were examined. The data was analysed using the Mann-Whitney-U statistical test. Results: There was no significant difference between the numbers of attached cells in the experimental group treated with MTAD and the control group treated with saline. Little or no attached cells were seen in the negative control group. Conclusion: RSD created an environment suitable for cell growth and attachment in a laboratory setting. The use of MTAD did not promote the attachment and growth of cells on the surface of human roots following RSD. PMID:23869124

  6. Effect of CO2, Nd:YAG and Er:YAG Lasers on Microtensile Bond Strength of Composite to Bleached-Enamel.

    PubMed

    Basir, Mahshid Mohammadi; Rezvani, Mohammad Bagher; Chiniforush, Nasim; Moradi, Zohreh

    2016-01-01

    Tooth restoration immediately after bleaching is challenging due to the potential problems in achieving adequate bond strength. The aim of this study was to evaluate the effect of surface treatment with ER:YAG, ND:YAG, CO2 lasers and 10% sodium ascorbate solution on immediate microtensile bond strength of composite resin to recently bleached enamel. Ninety sound molar teeth were randomly divided into three main groups (n:30) : NB (without bleaching), HB (bleached with 38% carbamide peroxide) and OB (bleached with Heydent bleaching gel assisted by diode laser). Each group was divided into five subgroups (n:6) : Si (without surface treatment), Er (Er:YAG laser), CO2 (CO2 laser), Nd (Nd:YAG laser) and As (Immersion in 10% sodium ascorbate solution). The bonding system was then applied and composite build-ups were constructed. The teeth were sectioned by low speed saw to obtain enamel- resin sticks and submitted to microtensile bond testing. Statistical analyses were done using two- way ANOVA, Tukey and Tamhane tests. µTBS of bleached teeth irradiated with ND:YAG laser was not significantly different from NB-Nd group. Microtensile bond strength of OB-Er group was higher than NB-Er and HB-Er groups. The mean µTBS of HB-CO2 group was higher than NB-CO2 group; the average µTBS of HB-As and OB-As groups was also higher than NB-As group. Use of Nd:YAG, CO2 lasers and 10% sodium ascorbate solution could improve the bond strength in home-bleached specimens. Application of ND:YAG laser on nonbleached specimens and Er:YAG laser on office-bleached specimens led to the highest µTBS in comparison to other surface treatments in each main group.

  7. Assessment of variations in thermal cycle life data of thermal barrier coated rods

    NASA Astrophysics Data System (ADS)

    Hendricks, R. C.; McDonald, G.

    An analysis of thermal cycle life data for 22 thermal barrier coated (TBC) specimens was conducted. The Zr02-8Y203/NiCrAlY plasma spray coated Rene 41 rods were tested in a Mach 0.3 Jet A/air burner flame. All specimens were subjected to the same coating and subsequent test procedures in an effort to control three parametric groups; material properties, geometry and heat flux. Statistically, the data sample space had a mean of 1330 cycles with a standard deviation of 520 cycles. The data were described by normal or log-normal distributions, but other models could also apply; the sample size must be increased to clearly delineate a statistical failure model. The statistical methods were also applied to adhesive/cohesive strength data for 20 TBC discs of the same composition, with similar results. The sample space had a mean of 9 MPa with a standard deviation of 4.2 MPa.

  8. Assessment of variations in thermal cycle life data of thermal barrier coated rods

    NASA Technical Reports Server (NTRS)

    Hendricks, R. C.; Mcdonald, G.

    1981-01-01

    An analysis of thermal cycle life data for 22 thermal barrier coated (TBC) specimens was conducted. The Zr02-8Y203/NiCrAlY plasma spray coated Rene 41 rods were tested in a Mach 0.3 Jet A/air burner flame. All specimens were subjected to the same coating and subsequent test procedures in an effort to control three parametric groups; material properties, geometry and heat flux. Statistically, the data sample space had a mean of 1330 cycles with a standard deviation of 520 cycles. The data were described by normal or log-normal distributions, but other models could also apply; the sample size must be increased to clearly delineate a statistical failure model. The statistical methods were also applied to adhesive/cohesive strength data for 20 TBC discs of the same composition, with similar results. The sample space had a mean of 9 MPa with a standard deviation of 4.2 MPa.

  9. Scale effects in the response and failure of fiber reinforced composite laminates loaded in tension and in flexure

    NASA Technical Reports Server (NTRS)

    Jackson, Karen E.; Kellas, Sotiris; Morton, John

    1992-01-01

    The feasibility of using scale model testing for predicting the full-scale behavior of flat composite coupons loaded in tension and beam-columns loaded in flexure is examined. Classical laws of similitude are applied to fabricate and test replica model specimens to identify scaling effects in the load response, strength, and mode of failure. Experiments were performed on graphite-epoxy composite specimens having different laminate stacking sequences and a range of scaled sizes. From the experiments it was deduced that the elastic response of scaled composite specimens was independent of size. However, a significant scale effect in strength was observed. In addition, a transition in failure mode was observed among scaled specimens of certain laminate stacking sequences. A Weibull statistical model and a fracture mechanics based model were applied to predict the strength scale effect since standard failure criteria cannot account for the influence of absolute specimen size on strength.

  10. DNA Sequences from Formalin-Fixed Nematodes: Integrating Molecular and Morphological Approaches to Taxonomy

    PubMed Central

    Thomas, W. Kelley; Vida, J. T.; Frisse, Linda M.; Mundo, Manuel; Baldwin, James G.

    1997-01-01

    To effectively integrate DNA sequence analysis and classical nematode taxonomy, we must be able to obtain DNA sequences from formalin-fixed specimens. Microdissected sections of nematodes were removed from specimens fixed in formalin, using standard protocols and without destroying morphological features. The fixed sections provided sufficient template for multiple polymerase chain reaction-based DNA sequence analyses. PMID:19274156

  11. The use of impact force as a scale parameter for the impact response of composite laminates

    NASA Technical Reports Server (NTRS)

    Jackson, Wade C.; Poe, C. C., Jr.

    1992-01-01

    The building block approach is currently used to design composite structures. With this approach, the data from coupon tests is scaled up to determine the design of a structure. Current standard impact tests and methods of relating test data to other structures are not generally understood and are often used improperly. A methodology is outlined for using impact force as a scale parameter for delamination damage for impacts of simple plates. Dynamic analyses were used to define ranges of plate parameters and impact parameters where quasi-static analyses are valid. These ranges include most low velocity impacts where the mass of the impacter is large and the size of the specimen is small. For large mass impacts of moderately thick (0.35 to 0.70 cm) laminates, the maximum extent of delamination damage increased with increasing impact force and decreasing specimen thickness. For large mass impact tests at a given kinetic energy, impact force and hence delamination size depends on specimen size, specimen thickness, boundary conditions, and indenter size and shape. If damage is reported in terms of impact force instead of kinetic energy, large mass test results can be applied directly to other plates of the same size.

  12. The use of impact force as a scale parameter for the impact response of composite laminates

    NASA Technical Reports Server (NTRS)

    Jackson, Wade C.; Poe, C. C., Jr.

    1992-01-01

    The building block approach is currently used to design composite structures. With this approach, the data from coupon tests are scaled up to determine the design of a structure. Current standard impact tests and methods of relating test data to other structures are not generally understood and are often used improperly. A methodology is outlined for using impact force as a scale parameter for delamination damage for impacts of simple plates. Dynamic analyses were used to define ranges of plate parameters and impact parameters where quasi-static analyses are valid. These ranges include most low-velocity impacts where the mass of the impacter is large, and the size of the specimen is small. For large-mass impacts of moderately thick (0.35-0.70 cm) laminates, the maximum extent of delamination damage increased with increasing impact force and decreasing specimen thickness. For large-mass impact tests at a given kinetic energy, impact force and hence delamination size depends on specimen size, specimen thickness, boundary conditions, and indenter size and shape. If damage is reported in terms of impact force instead of kinetic energy, large-mass test results can be applied directly to other plates of the same thickness.

  13. Human aflatoxin exposure in Kenya, 2007: a cross-sectional study

    PubMed Central

    Yard, Ellen E.; Daniel, Johnni H.; Lewis, Lauren S.; Rybak, Michael E.; Paliakov, Ekaterina M.; Kim, Andrea A.; Montgomery, Joel M.; Bunnell, Rebecca; Abudo, Mamo Umuro; Akhwale, Willis; Breiman, Robert F.; Sharif, Shahnaaz K.

    2013-01-01

    Aflatoxins contaminate approximately 25% of agricultural products worldwide. They can cause liver failure and liver cancer. Kenya has experienced multiple aflatoxicosis outbreaks in recent years, often resulting in fatalities. However, the full extent of aflatoxin exposure in Kenya has been unknown. Our objective was to quantify aflatoxin exposure across Kenya. We analysed aflatoxin levels in serum specimens from the 2007 Kenya AIDS Indicator Survey – a nationally representative, cross-sectional serosurvey. KAIS collected 15,853 blood specimens. Of the 3180 human immunodeficiency virus-negative specimens with ≥1 mL sera, we randomly selected 600 specimens stratified by province and sex. We analysed serum specimens for aflatoxin albumin adducts by using isotope dilution MS/MS to quantify aflatoxin B1-lysine, and normalised with serum albumin. Aflatoxin concentrations were then compared by demographic, socioeconomic and geographic characteristics. We detected serum aflatoxin B1-lysine in 78% of serum specimens (range =

  14. Acoustic emission spectral analysis of fiber composite failure mechanisms

    NASA Technical Reports Server (NTRS)

    Egan, D. M.; Williams, J. H., Jr.

    1978-01-01

    The acoustic emission of graphite fiber polyimide composite failure mechanisms was investigated with emphasis on frequency spectrum analysis. Although visual examination of spectral densities could not distinguish among fracture sources, a paired-sample t statistical analysis of mean normalized spectral densities did provide quantitative discrimination among acoustic emissions from 10 deg, 90 deg, and plus or minus 45 deg, plus or minus 45 deg sub s specimens. Comparable discrimination was not obtained for 0 deg specimens.

  15. The outcome of the seminal fluid parameters collected via coitus interruptus versus masturbation.

    PubMed

    Bahyah, M Kamarul; Murad, Z Ahmad; Ghazali, I; Roszaman, R; Noraziana, A W; Mokhtar, A; Omar, M H

    2010-03-01

    A one year study was carried out to determine the outcome of the seminal fluid parameters collected via masturbation and coitus interruptus in 151 patients who were undergoing intrauterine insemination (IUI) and patients who came for seminal analysis. There were no statistically significant differences in terms of volume, concentration, progressive motility and normal morphology from specimens collected via coitus interruptus compared to specimens collected via masturbation. Pregnancy outcomes were also comparable.

  16. Life prediction methodology for ceramic components of advanced heat engines. Phase 1: Volume 2, Appendices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-03-01

    This volume presents the following appendices: ceramic test specimen drawings and schematics, mixed-mode and biaxial stress fracture of structural ceramics for advanced vehicular heat engines (U. Utah), mode I/mode II fracture toughness and tension/torsion fracture strength of NT154 Si nitride (Brown U.), summary of strength test results and fractography, fractography photographs, derivations of statistical models, Weibull strength plots for fast fracture test specimens, and size functions.

  17. Revisiting the Estimation of Dinosaur Growth Rates

    PubMed Central

    Myhrvold, Nathan P.

    2013-01-01

    Previous growth-rate studies covering 14 dinosaur taxa, as represented by 31 data sets, are critically examined and reanalyzed by using improved statistical techniques. The examination reveals that some previously reported results cannot be replicated by using the methods originally reported; results from new methods are in many cases different, in both the quantitative rates and the qualitative nature of the growth, from results in the prior literature. Asymptotic growth curves, which have been hypothesized to be ubiquitous, are shown to provide best fits for only four of the 14 taxa. Possible reasons for non-asymptotic growth patterns are discussed; they include systematic errors in the age-estimation process and, more likely, a bias toward younger ages among the specimens analyzed. Analysis of the data sets finds that only three taxa include specimens that could be considered skeletally mature (i.e., having attained 90% of maximum body size predicted by asymptotic curve fits), and eleven taxa are quite immature, with the largest specimen having attained less than 62% of predicted asymptotic size. The three taxa that include skeletally mature specimens are included in the four taxa that are best fit by asymptotic curves. The totality of results presented here suggests that previous estimates of both maximum dinosaur growth rates and maximum dinosaur sizes have little statistical support. Suggestions for future research are presented. PMID:24358133

  18. Role of enamel deminerlization and remineralization on microtensile bond strength of resin composite.

    PubMed

    Rizvi, Abbas; Zafar, Muhammad S; Al-Wasifi, Yasser; Fareed, Wamiq; Khurshid, Zohaib

    2016-01-01

    This study is aimed to establish the microtensile bond strength of enamel following exposure to an aerated drink at various time intervals with/without application of remineralization agent. In addition, degree of remineralization and demineralization of tooth enamel has been assessed using polarized light microscopy. Seventy extracted human incisors split into two halves were immersed in aerated beverage (cola drink) for 5 min and stored in saliva until the time of microtensile bond testing. Prepared specimens were divided randomly into two study groups; remineralizing group (n = 70): specimens were treated for remineralization using casein phosphopeptides and amorphous calcium phosphate (CPP-ACP) remineralization agent (Recaldent™; GC Europe) and control group (n = 70): no remineralization treatment; specimens were kept in artificial saliva. All specimens were tested for microtensile bond strength at regular intervals (1 h, 1 days, 2 days, 1 week, and 2 weeks) using a universal testing machine. The results statistically analyzed (P = 0.05) using two-way ANOVA test. Results showed statistically significant increase in bond strength in CPP-ACP tested group (P < 0.05) at all-time intervals. The bond strength of remineralizing group samples at 2 days (~13.64 megapascals [MPa]) is comparable to that of control group after 1 week (~12.44 MPa). CPP-ACP treatment of teeth exposed to an aerated drink provided significant increase in bond strength at a shorter interval compared to teeth exposed to saliva alone.

  19. Microwave radiation is effective at disinfecting dental stone surfaces without changing their physical properties.

    PubMed

    Bona, Ariel José; Amaral-Brito, Mauro Gustavo; Rodrigues, José Augusto; Peruzzo, Daiane Cristina; França, Fabiana Mantovani Gomes

    2017-01-01

    The aims of this study were to evaluate the effectiveness of different microwave radiation regimens for disinfection of type IV dental stone surfaces and to assess the influence of these regimens on surface roughness and dimensional change following disinfection. Three hundred cylindrical (20 × 2-mm) test specimens were made in type IV stone and divided into subgroups of 20 according to the microorganisms tested (Staphylococcus aureus, Escherichia coli, or Candida albicans) and the 900-W microwave radiation protocol (cycles of 3, 5, or 7 minutes; a positive control; or a negative control). To test physical changes, 80 test specimens were made with the same dimensions except that they had 2 parallel and symmetrical indentations measuring 8 × 4 mm. These specimens were divided into 4 subgroups of 20 each (a subgroup for each radiation time and a negative control). The mean dimensional change and roughness data were analyzed by mixed models for repeated measures and Tukey-Kramer tests. Disinfection was analyzed with descriptive statistics. For E coli and C albicans, all radiation times proved effective at sterilizing the test specimens. For S aureus, sterilization was achieved with 5 and 7 minutes of exposure; however, colonies were observed in 10 Petri dishes (50%) exposed to 3 minutes of microwave radiation. No statistically significant difference in dimensional change or surface roughness was observed for any radiation regimen (P > 0.05).

  20. Effect of Home Bleaching on the Translucency of CAD/CAM Systems.

    PubMed

    Karci, Muhammet; Demir, Necla

    2017-11-10

    To evaluate the effect of a home bleaching agent (Opalescence PF) on the translucency of CAD/CAM ceramic systems. The 28 sintered ceramic specimens (IPS Empress CAD and IPS e.max CAD; 15 mm long, 10 mm wide, 1 mm thick) were divided into two subgroups as control and bleaching groups (n = 7). Carbamide peroxide (CP), 16%, home bleaching agent was applied onto the surface of each specimen for 6 hours per day for 7 days. A spectrophotometer (VITA Easyshade Advance) was used to measure the CIE L * a * b * coordinates and the reflectance value (Y) of the specimens on white and black backgrounds. The translucency parameter (TP), contrast ratio (CR), and opalescence parameter (OP) of the specimens were calculated. The data were statistically analyzed using Kolmogorov-Smirnov, one-way ANOVA, Tukey's test, and Pearson's correlation. Statistically significant differences in the TP values after 16% CP bleaching treatment were observed (p ˂ 0.05); however, no significant differences were found in the OP and CR values after the surface treatment (p ˃ 0.05). According to our study, patients who have all-ceramic restorations in their mouths should be careful when using home bleaching agents, because whitening agents can affect the translucency of all-ceramic restorations such as e.max CAD and Empress CAD. © 2017 by the American College of Prosthodontists.

  1. Ultrasonic Phased Array Sound Field Mapping Through Large-Bore Coarse Grained Cast Austenitic Stainless Steel (CASS) Piping Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cinson, Anthony D.; Crawford, Susan L.; Prowant, Matthew S.

    2012-04-16

    A sound field beam mapping exercise was conducted to further understand the effects of coarse grained microstructures found in CASS materials on phased array ultrasonic wave propagation. Laboratory measurements were made on three CASS specimens with different microstructures; the specimens were polished and etched to reveal measurable grain sizes, shapes and orientations. Three longitudinal, phased array probes were fixed on a specimen's outside diameter with the sound field directed toward one end (face) of the pipe segment over a fixed range of angles. A point receiver was raster scanned over the surface of the specimen face generating a sound fieldmore » image. A slice of CASS material was then removed from the specimen end and the beam mapping exercise repeated. The sound fields acquired were analyzed for spot size, coherency, and beam redirection. Analyses were conducted between the resulting sound fields and the microstructural characteristics of each specimen.« less

  2. Is Ki67 prognostic for aggressive prostate cancer? A multicenter real-world study.

    PubMed

    Fantony, Joseph J; Howard, Lauren E; Csizmadi, Ilona; Armstrong, Andrew J; Lark, Amy L; Galet, Colette; Aronson, William J; Freedland, Stephen J

    2018-06-15

    To test if Ki67 expression is prognostic for biochemical recurrence (BCR) after radical prostatectomy (RP). Ki67 immunohistochemistry was performed on tissue microarrays constructed from specimens obtained from 464 men undergoing RP at the Durham and West LA Veterans Affairs Hospitals. Hazard ratios (HR) for Ki67 expression and time to BCR were estimated using Cox regression. Ki67 was associated with more recent surgery year (p < 0.001), positive margins (p = 0.001) and extracapsular extension (p < 0.001). In center-stratified analyses, the adjusted HR for Ki67 expression and BCR approached statistical significance for west LA (HR: 1.54; p = 0.06), but not Durham (HR: 1.10; p = 0.74). This multi-institutional 'real-world' study provides limited evidence for the prognostic role of Ki67 in predicting outcome after RP.

  3. SEM-EDS Analyses of Small Craters in Stardust Aluminum Foils: Implications for the Wild-2 Dust Distribution

    NASA Technical Reports Server (NTRS)

    Borg, J.; Horz, F.; Bridges, J. C.; Burchell, M. J.; Djouadi, Z.; Floss, C.; Graham, G. A.; Green, S. F.; Heck, P. R.; Hoppe, P.; hide

    2007-01-01

    Aluminium foils were used on Stardust to stabilize the aerogel specimens in the modular collector tray. Part of these foils were fully exposed to the flux of cometary grains emanating from Wild 2. Because the exposed part of these foils had to be harvested before extraction of the aerogel, numerous foil strips some 1.7 mm wide and 13 or 33 mm long were generated during Stardusts's Preliminary Examination (PE). These strips are readily accommodated in their entirety in the sample chambers of modern SEMs, thus providing the opportunity to characterize in situ the size distribution and residue composition - employing EDS methods - of statistically more significant numbers of cometary dust particles compared to aerogel, the latter mandating extensive sample preparation. We describe here the analysis of nearly 300 impact craters and their implications for Wild 2 dust.

  4. Characterization of the Edge Crack Torsion (ECT) Test for Mode III Fracture Toughness Measurement of Laminated Composites

    NASA Technical Reports Server (NTRS)

    Ratcliffe, James G.

    2004-01-01

    The edge crack torsion (ECT) test is designed to initiate mode III delamination growth in composite laminates. The test has undergone several design changes during its development. The objective of this paper was to determine the suitability of the current ECT test design a mode III fracture test. To this end, ECT tests were conducted on specimens manufactured from IM7/8552 and S2/8552 tape laminates. Three-dimensional finite element analyses were performed. The analysis results were used to calculate the distribution of mode I, mode II, and mode III strain energy release rate along the delamination front. The results indicated that mode IIIdominated delamination growth would be initiated from the specimen center. However, in specimens of both material types, the measured values of GIIIc exhibited significant dependence on delamination length. Load-displacement response of the specimens exhibited significant deviation from linearity before specimen failure. X-radiographs of a sample of specimens revealed that damage was initiated in the specimens prior to failure. Further inspection of the failure surfaces is required to identify the damage and determine that mode III delamination is initiated in the specimens.

  5. Sexual dimorphism in Ramphastos toco and Ramphastos dicolorus (Piciformes, Aves).

    PubMed

    Castro, Márcio S; Recco-Pimentel, Shirlei M; Rocha, Guaracy T

    2003-03-01

    Phenotypic sexual dimorphism seems to be rare in the Ramphastidae family, except in Pteroglossus viridis and in the genus Selenidera. Many breeders of wild birds believe that specimens of Ramphastos toco can be sexed using bill characteristics. In this study, various discriminant phenotypic variables were analyzed in birds which were sexed cytogenetically. Fifty-one specimens of R. toco and 20 R. dicolorus were studied. The statistically significant parameters which served to distinguish the sex in these species were the length of the culmen and tomium, length of the lower corneous beak and the cloaca. Using these parameters, captive bird breeders can determine sex of R. toco specimens by phenotypic analysis and form breeding couples more quickly.

  6. SurePath Specimens Versus ThinPrep Specimen Types on the COBAS 4800 Platform: High-Risk HPV Status and Cytology Correlation in an Ethnically Diverse Bronx Population.

    PubMed

    Naeem, R C; Goldstein, D Y; Einstein, Mark H; Ramos Rivera, G; Schlesinger, K; Khader, S N; Suhrland, M; Fox, A S

    2017-08-01

    To compare the cytologic preparations of 130 cervical specimens (from women of various ethnicities at high risk for human papillomavirus [HPV] infection) using the SurePath (SP) collection system with specimens gathered using the ThinPrep (TP) system, as processed on the Cobas 4800 analyzer, to determine which collection method more accurately identifies HPV infection. In our prospective study, specimens were collected from 130 women of various ethnicities residing in or near Bronx County, NY. The SP-collected specimen was first processed for cytologic findings; if clinical HPV testing was requested on that specimen, it was tested using Hybrid Capture II (HC2) methodology. We tested the remnant SP-collected cell concentrate using the Cobas analyzer. Then, the TP-collected and SP-collected specimens were tested in the same run on that analyzer, and the results were compared. We also compared the results with the concurrent cytologic findings. The results were concordant for overall HR-HPV status in 93.8% of cases. Also, a statistically significant lower cycle threshold value was observed with Cobas testing of specimen concentrates tested via the BD SurePath Pap Test (P = .001), suggesting higher sensitivity compared with specimens tested via the ThinPrep Pap Test. Cobas 4800 HPV testing of SP-collected specimen concentrates yields comparable results to TP-collected specimen concentrates. Based on the limited data that we derived, SP collection may be a more favorable methodology than TP collection for HPV testing of individuals at high risk in our ethnically diverse, urban patient population. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  7. Inhibitory effects of acid water prepared by an electrolysis apparatus on early plaque formation on specimens of dentine.

    PubMed

    Ito, K; Nishida, T; Murai, S

    1996-05-01

    The aim of this study was to compare the effects of acid water prepared by an electrolysis apparatus with placebo treatment on the ultrastructure of early plaque formed on dentine specimens attached to retainers in the oral cavity. Dentine specimens were taken from 12 healthy extracted human 3rd molars. 4 dentine specimens were placed in the both the right and left buccal flanges of retainers fabricated from self-setting acrylic resin. The retainers were placed on both maxillary buccal sites in 6 subjects. The test solution was acid water (AW) prepared by an electrolysis apparatus with a pH of 2.7 and an oxidation-reduction potential of more than 1100 mV. As a positive control, 0.2% chlorhexidine digluconate (CHX) solution was used and normal saline solution as a negative control. 4 specimens placed in the right and left retainers were randomly allocated to 4 treatments as follows: treatment A, washing with AW; treatment B, washing with CHX solution; treatment C, washing with normal saline; treatment D, no washing. Washing was carried out in a plastic beaker containing 30 ml of each solution for 30s 2X daily over a 7-day period. The specimens were then carefully removed from the retainers, the morphology and thickness of the plaque formed examined by SEM, and the developmental condition of the plaque analyzed statistically. The plaque on the specimens in treatments A and B consisted mainly of coccoid forms. Mature plaque formation with complex flora was seen on the specimens in treatments C and D. The mean thickness of the plaque deposits on the dentin specimens as measured on SEM photographs magnified 2000 times was 8.80 mm for treatment. A, while in treatment B it was 3.90 mm. Plaque thickness for treatment C was 24.97 mm, and for treatment D 25.67 mm. The thickness of plaque formed on the sectioned specimens was significantly less for treatments A and B than for treatments C and D. However, there was no statistically significant difference between treatments A and B, and between treatments C and D (p < 0.0001). The results of this short-term study indicate that AW washing has almost the same potential for inhibition of plaque formation as CHX washing, and is more effective for inhibiting plaque formation than washing with sterile saline. It is therefore concluded that AW may be useful as an anti-plaque agent.

  8. A Multivariate Evaluation of Factors Affecting the Quality of Freshly Frozen Tissue Specimens.

    PubMed

    Wang, Tong-Hong; Chen, Chin-Chuan; Liang, Kung-Hao; Chen, Chi-Yuan; Chuang, Wen-Yu; Ueng, Shir-Hwa; Chu, Pao-Hsien; Huang, Chung-Guei; Chen, Tse-Ching; Hsueh, Chuen

    2017-08-01

    Well-prepared and preserved freshly frozen specimens are indispensable materials for clinical studies. To manage specimen quality and to understand the factors potentially affecting specimen quality during preservation processes, we analyzed the quality of RNA and genomic DNA of various tissues collected between 2002 and 2011 in Linkou Chang Gung Memorial Hospital, Taiwan. During this period, a total of 1059 freshly frozen specimens from eight major cancer categories were examined. It was found that preservation duration, organ origin, and tissue type could all influence the quality of RNA samples. The increased preservation period correlated with decreased RNA quality; the brain, breast, and stomach RNA specimens displayed faster degradation rates than those of other organs, and RNA specimens isolated from tumor tissues were apparently more stable than those of other tissues. These factors could all be used as quality predictors of RNA quality. In contrast, almost all analyses revealed that the genomic DNA samples had good quality, which was not influenced by the aforementioned factors. The results assisted us in determining preservation factors that affect specimen quality, which could provide evidence for improving processes of sample collection and preservation. Furthermore, the results are also useful for researchers to adopt as the evaluation criteria for choosing specimen collection and preservation strategies.

  9. Influence of precracked specimen configuration and starting stress intensity on the stress corrosion cracking of 4340 steel

    NASA Technical Reports Server (NTRS)

    Lisagor, W. B.

    1984-01-01

    Since the pioneer work of Brown (1966), precracked specimens and related fracture mechanics analyses have been extensively used to study stress corrosion cracking. Certain questions arose in connection with initial attempts to prepare standardized recommended practices by ASTM Committee G-1 on Corrosion of Metals. These questions were related to adequacy of test control as it pertains to acceptable limits of variability, and to validity of expressions for stress intensity and crack-surface displacements for both specimen configurations. An interlaboratory test program, was, therefore, planned with the objective to examine the validity of KIscc testing for selected specimen configurations, materials,and environmental systems. The results reported in the present paper include details of a single laboratory test program. The program was conducted to determine if the threshold value of stress intensity for onset and arrest of stress corrosion cracking was independent for the two specimen configurations examined.

  10. IRRADIATION-CAPSULE STUDY OF URANIUM MONOCARBIDE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Price, R.B.; Stahl, D.; Stang, J.H.

    1960-03-01

    Small cylindrical specimens of enriched UC were irradiated to evaluate usefulness as a high-temperature fuel for stationary power reactors. Detailed thermal and nuclear analyses were made to arrive at an appropriate capsule design on the basis of target specimen center-line temperature ( approximately 1500 deg F), specimen surface temperature (1100 deg F), specimen composition (U--5 wt.% C), and acapsule o.d. of 1.125 in. Temperature data from thermocouples inside the capsule indicated that five of the six capsules irradiated operated at close to the design conditions. Irradiation periods for individual capsules were varied to give burnups ranging from 1,000 to 20,000more » Mwd/t of U. Preliminary evidence indicates that this range of burnups was achieved. By using temperature and heat-flux data from the actual irradiations to estimate effective in-pile specimen thermal conductivities, it was found that the conductivity did not appear to vary during the exposures. (auth)« less

  11. Shear fatigue crack growth - A literature survey

    NASA Technical Reports Server (NTRS)

    Liu, H. W.

    1985-01-01

    Recent studies of shear crack growth are reviewed, emphasizing test methods and data analyses. The combined mode I and mode II elastic crack tip stress fields are considered. The development and design of the compact shear specimen are described, and the results of fatigue crack growth tests using compact shear specimens are reviewed. The fatigue crack growth tests are discussed and the results of inclined cracks in tensile panels, center cracks in plates under biaxial loading, cracked beam specimens with combined bending and shear loading, center-cracked panels and double edge-cracked plates under cyclic shear loading are examined and analyzed in detail.

  12. In vitro evaluation of marginal adaptation in five ceramic restoration fabricating techniques.

    PubMed

    Ural, Cağri; Burgaz, Yavuz; Saraç, Duygu

    2010-01-01

    To compare in vitro the marginal adaptation of crowns manufactured using ceramic restoration fabricating techniques. Fifty standardized master steel dies simulating molars were produced and divided into five groups, each containing 10 specimens. Test specimens were fabricated with CAD/CAM, heat-press, glass-infiltration, and conventional lost-wax techniques according to manufacturer instructions. Marginal adaptation of the test specimens was measured vertically before and after cementation using SEM. Data were statistically analyzed by one-way ANOVA with Tukey HSD tests (a = .05). Marginal adaptation of ceramic crowns was affected by fabrication technique and cementation process (P < .001). The lowest marginal opening values were obtained with Cerec-3 crowns before and after cementation (P < .001). The highest marginal discrepancy values were obtained with PFM crowns before and after cementation. Marginal adaptation values obtained in the compared systems were within clinically acceptable limits. Cementation causes a significant increase in the vertical marginal discrepancies of the test specimens.

  13. Biomarker discovery in biological specimens (plasma, hair, liver and kidney) of diabetic mice based upon metabolite profiling using ultra-performance liquid chromatography with electrospray ionization time-of-flight mass spectrometry.

    PubMed

    Tsutsui, Haruhito; Maeda, Toshio; Min, Jun Zhe; Inagaki, Shinsuke; Higashi, Tatsuya; Kagawa, Yoshiyuki; Toyo'oka, Toshimasa

    2011-05-12

    The number of diabetic patients has recently been increasing worldwide. Diabetes is a multifactorial disorder based on environmental factors and genetic background. In many cases, diabetes is asymptomatic for a long period and the patient is not aware of the disease. Therefore, the potential biomarker(s), leading to the early detection and/or prevention of diabetes mellitus, are strongly required. However, the diagnosis of the prediabetic state in humans is a very difficult issue, because the lifestyle is variable in each person. Although the development of a diagnosis method in humans is the goal of our research, the extraction and structural identification of biomarker candidates in several biological specimens (i.e., plasma, hair, liver and kidney) of ddY strain mice, which undergo naturally occurring diabetes along with aging, were carried out based upon a metabolite profiling study. The low-molecular-mass compounds including metabolites in the biological specimens of diabetic mice (ddY-H) and normal mice (ddY-L) were globally separated by ultra-performance liquid chromatography (UPLC) using different reversed-phase columns (i.e., T3-C18 and HS-F5) and detected by electrospray ionization time-of-flight mass spectrometry (ESI-TOF-MS). The biomarker candidates related to diabetes mellitus were extracted from a multivariate statistical analysis, such as an orthogonal partial least-squares-discriminant analysis (OPLS-DA), followed by a database search, such as ChemSpider, KEGG and HMDB. Many metabolites and unknown compounds in each biological specimen were detected as the biomarker candidates related to diabetic mellitus. Among them, the elucidation of the chemical structures of several possible metabolites, including more than two biological specimens, was carried out along with the comparison of the tandem MS/MS analyses using authentic compounds. One metabolite was clearly identified as N-acetyl-L-leucine based upon the MS/MS spectra and the retention time on the chromatograms. N-acetyl-L-leucine is an endogenous compound included in all biological specimens (plasma, hair, liver and kidney). Therefore, this metabolite appears to be a potential biomarker candidate related to diabetes. Although the structures of other biomarker candidates have still not yet determined, the present approach based upon a metabolite profiling study using UPLC-ESI-TOF-MS could be helpful for understanding the abnormal state of various diseases. Copyright © 2010 Elsevier B.V. All rights reserved.

  14. The effect of high energy ion beam analysis on D trapping in W

    NASA Astrophysics Data System (ADS)

    Finlay, T. J.; Davis, J. W.; Schwarz-Selinger, T.; Haasz, A. A.

    2017-12-01

    High energy ion beam analyses (IBA) are invaluable for measuring concentration depth profiles of light elements in solid materials, and important in the study of fusion fuel retention in tokamaks. Polycrystalline W specimens were implanted at 300 and 500 K, 5-10 × 1023 D m-2 fluence, with deuterium-only and simultaneous D-3%He ion beams. Selected specimens were analysed by elastic recoil detection analysis (ERDA) and/or nuclear reaction analysis (NRA). All specimens were measured by thermal desorption spectroscopy (TDS). The D TDS spectra show an extra peak at 900-1000 K following ERDA and/or NRA measurements. The peak height appears to correlate with the amount of D initially trapped beyond the calculated IBA probe beam peak damage depth. Similar to pre-implantation damage scenarios, the IBA probe beam creates empty high energy traps which later retrap D atoms during TDS heating, which is supported by modelling experimental results using the Tritium Migration Analysis Program.

  15. Hydrogen permeation properties of plasma-sprayed tungsten*1

    NASA Astrophysics Data System (ADS)

    Anderl, R. A.; Pawelko, R. J.; Hankins, M. R.; Longhurst, G. R.; Neiser, R. A.

    1994-09-01

    Tungsten has been proposed as a plasma-facing component material for advanced fusion facilities. This paper reports on laboratory-scale studies that were done to assess the hydrogen permeation properties of plasma-sprayed tungsten for such applications. The work entailed deuterium permeation measurements for plasma-sprayed (PS) tungsten coatings, sputter-deposited (SP) tungsten coatings, and steel substrate material using a mass-analyzed, 3 keV D 3+ ion beam with fluxes of ˜6.5 × 10 19 D/m 2 s. Extensive characterization analyses for the plasma-sprayed tungsten coatings were made using Auger spectrometry and scanning electron microscopy (SEM). Observed permeation rates through composite PS-tungsten/steel specimens were several orders of magnitude below the permeation levels observed for SP-tungsten/steel composite specimens and pure steel specimens. Characterization analyses indicated that the plasma-sprayed tungsten coating had a nonhomogeneous microstructure that consisted of splats with columnar solidification, partially-melted particles with grain boundaries, and void regions. Reduced permeation levels can be attributed to the complex microstructure and a substantial surface-connected porosity.

  16. A Geographic Information Systems (GIS)-based analysis of modern South African rodent distributions, habitat use, and environmental tolerances.

    PubMed

    Campbell, Timothy L; Lewis, Patrick J; Thies, Monte L; Williams, Justin K

    2012-11-01

    GOALS OF THIS STUDY WERE TO: (1) develop distributional maps of modern rodent genera throughout the countries of South Africa, Lesotho, and Swaziland by georeferencing museum specimens; (2) assess habitat preferences for genera by cross-referencing locality position with South African vegetation; and (3) identify mean annual precipitation and temperature range where the genera are located. Conterminous South Africa including the countries of Lesotho and Swaziland Digital databases of rodent museum specimens housed in the Ditsong National Museum of Natural History, South Africa (DM), and the Division of Mammals, National Museum of Natural History, Smithsonian Institution, United States (NMNH), were acquired and then sorted into a subset of specimens with associated coordinate data. The coordinate data were then used to develop distributional maps for the rodent genera present within the study area. Percent habitat occupation and descriptive statistics for six climatic variables were then determined for each genus by cross-referencing locality positions with vegetation and climatic maps. This report presents a series of maps illustrating the distribution of 35 rodent genera based on 19,471 geo-referenced specimens obtained from two major collections. Inferred habitat use by taxon is provided for both locality and specimen percent occurrence at three hierarchical habitat levels: biome, bioregion, and vegetation unit. Descriptive statistics for six climatic variables are also provided for each genus based on locality and specimen percent incidence. As rodent faunas are commonly used in paleoenvironmental reconstructions, an accurate assessment of rodent environmental tolerance ranges is necessary before confidence can be placed in an actualistic model. While the data presented here represent only a subset of the modern geographic distributions for many of the taxa examined, a wide range of environmental regimes are observed, suggesting that more research is necessary in order to accurately reconstruct an environmental signature when these taxa are found in the fossil record.

  17. Effect of five commercial mouth rinses on the microhardness of a nanofilled resin composite restorative material: An in vitro study

    PubMed Central

    Jyothi, KN; Crasta, Shanol; Venugopal, P

    2012-01-01

    Aim and Objectives: This in vitro study was designed to comparatively evaluate the effect of five commercial mouth rinses on the micro hardness of a nanofilled resin based restorative material. Materials and Methods: Fifty specimens of resin composite material (Filtek Z350XT, 3M ESPE, St.Paul, MN USA) were prepared and immersed in artificial saliva for 24 h. The base line micro hardness of specimens was recorded using Vicker's micro hardness tester (MMT – X7 Matsuzawa, Japan). The specimens were randomly distributed into five groups, each containing 10 specimens (n=10) as follows – Group I Listerine (alcohol based), Group II Periogard (alcohol based), Group III Colgate plax (alcohol based), Group IV C- prev (alcohol free), Group V Hiora(alcohol free). The specimens were immersed in 20 ml of mouth rinses and incubated for 24 h at 37°C. The post immersion micro hardness values of the specimens were recorded and the data was tabulated for statistical analysis. Kruskal–Wallis test was used for inter group comparison followed by pair wise comparison of groups using Mann–Whitney U test. The level of significance was set at P=0.05. Results: Significant reduction in the mean VHN (Vicker's micro hardness number) was observed in all the groups after exposure to the tested mouth rinses (P<0.01) and the reduction in mean VHN values were as follows: Group I 12.09, Group II 3.42, Group II 1.51, Group IV 1.03, Group V 0.57. Inter group comparison showed statistically significant reduction in micro hardness in Groups I and II compared to all other groups with P<0.001. There was no significant difference between Groups III, IV and V. Conclusion: All the mouth rinses showed a reduction in the microhardness of nanofilled resin composite material with listerine (Group I) containing maximum amount of alcohol, showing highest reduction in micro hardness value. PMID:22876004

  18. Effect of the addition of silanated silica on the mechanical properties of microwave heat-cured acrylic resin.

    PubMed

    da Silva, Lucas H; Feitosa, Sabrina A; Valera, Marcia C; de Araujo, Maria A M; Tango, Rubens N

    2012-06-01

    The purpose of this study was to evaluate the flexural strength and Vickers hardness of a microwave energy heat-cured acrylic resin by adding different concentrations of silane surface-treated nanoparticle silica. Acrylic resin specimens with dimensions of 65 × 10 × 2.5 mm were formed and divided into five experimental groups (n = 10) according to the silica concentration added to the acrylic resin mass (weight %) prior to polymerisation : G1, without silica; G2, 0.1% silica; G3, 0.5% silica; G4, 1.0% silica; and G5, 5.0% silica. The specimens were submitted to a three-point flexural strength test and to the Vickers hardness test (HVN). The data obtained were statistically analysed by anova and the Tukey test (α = 0.05). Regarding flexural strength, G5 differed from the other experimental groups (G1, G2, G3 and G4) presenting the lowest mean, while G4 presented a significantly higher mean, with the exception of group G3. Regarding Vickers hardness, a decrease in values was observed, in which G1 presented the highest hardness compared with the other experimental groups. Incorporating surface-treated silica resulted in direct benefits in the flexural strength of the acrylic resin activated by microwave energy; however, similar results were not achieved for hardness. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

  19. [Differentiation by geometric morphometrics among 11 Anopheles (Nyssorhynchus) in Colombia].

    PubMed

    Calle, David Alonso; Quiñones, Martha Lucía; Erazo, Holmes Francisco; Jaramillo, Nicolás

    2008-09-01

    The correct identification of the Anopheles species of the subgenus Nyssorhynchus is important because this subgenus includes the main malaria vectors in Colombia. This information is necessary for focusing a malaria control program. Geometric morphometrics were used to evaluate morphometric variation of 11 species of subgenus Nyssorhynchus present in Colombia and to distinguish females of each species. Materials and methods. The specimens were obtained from series and family broods from females collected with protected human hosts as attractants. The field collected specimens and their progeny were identified at each of the associated stages by conventional keys. For some species, wild females were used. Landmarks were selected on wings from digital pictures from 336 individuals, and digitized with coordinates. The coordinate matrix was processed by generalized Procrustes analysis which generated size and shape variables, free of non-biological variation. Size and shape variables were analyzed by univariate and multivariate statistics. The subdivision of subgenus Nyssorhynchus in sections is not correlated with wing shape. Discriminant analyses correctly classified 97% of females in the section Albimanus and 86% in the section Argyritarsis. In addition, these methodologies allowed the correct identification of 3 sympatric species from Putumayo which have been difficult to identify in the adult female stage. The geometric morphometrics were demonstrated to be a very useful tool as an adjunct to taxonomy of females the use of this method is recommended in studies of the subgenus Nyssorhynchus in Colombia.

  20. The effect of accelerated ageing on colour stability of visible light-cured (VLC) chairside denture liners.

    PubMed

    Kostoulas, Ioannis; Polyzois, Gregory; Mitsoudis, Anastasios; Kavoura, Victoria; Frangou, Maria

    2012-06-01

    The purpose of this study was to assess the colour stability of seven visible light-cured (VLC) hard and soft denture liners by an in vitro accelerated ageing test and compare them with two autopolymerised hard and soft liners. Ten specimens of each material were fabricated. The initial colour was measured with a tri-stimulus colorimeter. One set of five specimens was placed in distilled water at 37°C in the dark for 15 days, while the remaining were subjected to UV/visible light-accelerated ageing initially for 24 h and then for 144 h. Colour change (ΔΕ) was calculated. Data were statistically analysed by anova, Tukey and t-tests at α = 0.05. All the liners showed clinically acceptable colour change (ΔΕ ≤ 6.8) in distilled water. The colour changes after ageing for Triad DuaLine, Lightdon U, Ufi Gel H and Light Liner Hard were clinically unacceptable (ΔΕ ≥ 6.8), whereas LightLiner Soft, Astron LC Soft, Triad Resiline and Flexacryl Soft presented slighter and clinically acceptable colour change (ΔΕ ≤ 6.8). Accelerated ageing affected significantly the colour stability of all denture liners tested except Astron LC Soft. Soft VLC denture liners were more colour-stable than hard VLC liners. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  1. Evaluation of the surface roughness of three heat-cured acrylic denture base resins with different conventional lathe polishing techniques: A comparative study.

    PubMed

    Rao, Duggineni Chalapathi; Kalavathy, N; Mohammad, H S; Hariprasad, A; Kumar, C Ravi

    2015-01-01

    Surface roughness promotes adhesion and colonization of denture plaque. Therefore, it is important to know the effects of polishing and finishing on the surface roughness of various acrylic resin materials. To evaluate and compare the effects of different conventional lathe polishing techniques on heat cured acrylic resins in producing surface roughness. Three different commercially available heat-cured acrylic resin materials namely DPI, Meliodent and Trevalon Hi were selected. 30 Specimens of each acrylic material (30 x 3 = 90, 10 x 60 x 2mm) were prepared and divided into 5 groups, each group consisted of 6 Nos. of specimens per material(6x3=18) and were grouped as Group A(unfinished), Group B (finished), Group C (Polishing Paste), Group D (Polishing Cake) and Group E (Pumice and Gold rouge). The resulted surface roughness (μm) was measured using Perthometer and observed under Scanning Electron Microscope. The values obtained were subjected statistical analyses. Among the materials tested, better results were obtained with Trevalon Hi followed by Meliodent and DPI. Among the polishing methods used, superior results were obtained with universal polishing paste followed by polishing cake; Pumice and Gold rouge. Although Pumice and Gold rouge values produced greater roughness value, they were well within the threshold value of 0.2 mm.

  2. Comparisons of Fabric Strength and Development in Polycrystalline Ice at Atmospheric and Basal Hydrostatic Pressures

    NASA Astrophysics Data System (ADS)

    Breton, Daniel; Baker, Ian; Cole, David

    2013-04-01

    Understanding and predicting the flow of polycrystalline ice is crucial to ice sheet modeling and paleoclimate reconstruction from ice cores. Ice flow rates depend strongly on the fabric (i.e. the distribution of grain sizes and crystallographic orientations) which evolves over time and enhances the flow rate in the direction of applied stress. The mechanisms for fabric evolution in ice have been extensively studied at atmospheric pressures, but little work has been done to observe these processes at the high pressures experienced deep within ice sheets where long-term changes in ice rheology are expected to have significance. We conducted compressive creep tests to ~10% strain on 917 kg m-3, initially randomly-oriented polycrystalline ice specimens at 0.1 (atmospheric) and 20 MPa (simulating ~2,000 m depth) hydrostatic pressures, performing microstructural analyses on the resulting deformed specimens to characterize the evolution and strength of crystal fabric. Our microstructural analysis technique simultaneously collects grain shape and size data from Scanning Electron Microscope (SEM) micrographs and obtains crystallographic orientation data via Electron BackScatter Diffraction (EBSD). Combining these measurements allows rapid analysis of the ice fabric over large numbers of grains, yielding statistically useful numbers of grain size and orientation data. We present creep and microstructural data to demonstrate pressure-dependent effects on the mechanical and microstructural evolution of polycrystalline ice and discuss possible mechanisms for the observed differences.

  3. Single-trabecula building block for large-scale finite element models of cancellous bone.

    PubMed

    Dagan, D; Be'ery, M; Gefen, A

    2004-07-01

    Recent development of high-resolution imaging of cancellous bone allows finite element (FE) analysis of bone tissue stresses and strains in individual trabeculae. However, specimen-specific stress/strain analyses can include effects of anatomical variations and local damage that can bias the interpretation of the results from individual specimens with respect to large populations. This study developed a standard (generic) 'building-block' of a trabecula for large-scale FE models. Being parametric and based on statistics of dimensions of ovine trabeculae, this building block can be scaled for trabecular thickness and length and be used in commercial or custom-made FE codes to construct generic, large-scale FE models of bone, using less computer power than that currently required to reproduce the accurate micro-architecture of trabecular bone. Orthogonal lattices constructed with this building block, after it was scaled to trabeculae of the human proximal femur, provided apparent elastic moduli of approximately 150 MPa, in good agreement with experimental data for the stiffness of cancellous bone from this site. Likewise, lattices with thinner, osteoporotic-like trabeculae could predict a reduction of approximately 30% in the apparent elastic modulus, as reported in experimental studies of osteoporotic femora. Based on these comparisons, it is concluded that the single-trabecula element developed in the present study is well-suited for representing cancellous bone in large-scale generic FE simulations.

  4. FX enzyme and GDP-L-Fuc transporter expression in colorectal cancer.

    PubMed

    Villar-Portela, Susana; Muinelo-Romay, Laura; Cuevas, Elisa; Gil-Martín, Emilio; Fernández-Briera, Almudena

    2013-08-01

    Fucosylation is regulated by fucosyltransferases, the guanosine diphosphate-L-fucose (GDP-L-Fuc) synthetic pathway, and the GDP-L-fucose transporter (GDP-L-Fuc Tr). We have reported previously an increased level of α(1,6)fucosyltransferase activity and expression in colorectal cancer (CRC). The present study aimed to analyse the expression profiles of the FX enzyme and GDP-L-Fuc Tr in a cohort of operated CRC patients to elucidate their role in α(1,6)fucosylation in this neoplasm. We assessed the immunohistochemical expression of FX and GDP-L-Fuc Tr in a series of tumour samples and healthy tissues from CRC specimens. FX expression was observed in 58 of 91 (63.7%) tumours and 23 of 28 (82.1%) corresponding healthy samples. GDP-L-Fuc Tr expression was detected in 86 of 102 (84.3%) colorectal tumours, and 13 of 27 (48.1%) healthy tissue specimens. The expression of GDP-L-Fuc Tr was statistically higher in tumours than in healthy tissues (P < 0.001). A correlation was found between FX and GDP-L-Fuc Tr expression in tumour samples (P = 0.003). GDP-L-Fuc Tr overexpression in the tumour tissue of CRC patients suggests that GDP-L-Fuc transport to the Golgi apparatus may be an important factor associated with increased α(1,6)fucosylation in CRC. © 2013 John Wiley & Sons Ltd.

  5. Trypanosomatids (Protozoa: Kinetoplastida) in three species of Armored Catfish from Mogi-Guaçu river, Pirassununga, São Paulo, Brazil.

    PubMed

    Molina, Julia Pereira; Madi, Rubens Riscala; Solferini, Vera Nisaka; Ceccarelli, Paulo Sérgio; Pinheiro, Hildete Prisco; Ueta, Marlene Tiduko

    2016-06-07

    Trypanosome infections have been reported in several species of fish, in majority of cases described on the basis of morphological characteristics. Trypanosomes in fish are heteroxenous and transmitted by hirudineans. This study aims to evaluate the prevalence and density of infections by Trypanosoma sp. in blood from three species of catfish, Hypostomus regani, H. strigaticeps, H. albopunctatus, from the Mogi Guaçu River, Pirassununga, São Paulo, Brazil. Further, this study intends to characterize the Trypanosoma specimens found in the blood of these fish by morphological and molecular techniques. The trypanosomes overall prevalence observed was 47.6% with a general average density of 0.75 parasites/µl of blood. Hypostomus regani and Hypostomus strigaticeps showed a significant difference in prevalence. The average densities of parasites were not significantly different among the three fish species. Similar findings were observed for the monthly variations in densities. The parasites found in the three species of catfish studied showed similar morphological characteristics. The morphological data and the statistical analyses used in this study didn't show the formation of groups. The analyses provided evidence of the presence of pleomorphisms in the trypanosomes found in the three studied fish.

  6. CEQer: a graphical tool for copy number and allelic imbalance detection from whole-exome sequencing data.

    PubMed

    Piazza, Rocco; Magistroni, Vera; Pirola, Alessandra; Redaelli, Sara; Spinelli, Roberta; Redaelli, Serena; Galbiati, Marta; Valletta, Simona; Giudici, Giovanni; Cazzaniga, Giovanni; Gambacorti-Passerini, Carlo

    2013-01-01

    Copy number alterations (CNA) are common events occurring in leukaemias and solid tumors. Comparative Genome Hybridization (CGH) is actually the gold standard technique to analyze CNAs; however, CGH analysis requires dedicated instruments and is able to perform only low resolution Loss of Heterozygosity (LOH) analyses. Here we present CEQer (Comparative Exome Quantification analyzer), a new graphical, event-driven tool for CNA/allelic-imbalance (AI) coupled analysis of exome sequencing data. By using case-control matched exome data, CEQer performs a comparative digital exonic quantification to generate CNA data and couples this information with exome-wide LOH and allelic imbalance detection. This data is used to build mixed statistical/heuristic models allowing the identification of CNA/AI events. To test our tool, we initially used in silico generated data, then we performed whole-exome sequencing from 20 leukemic specimens and corresponding matched controls and we analyzed the results using CEQer. Taken globally, these analyses showed that the combined use of comparative digital exon quantification and LOH/AI allows generating very accurate CNA data. Therefore, we propose CEQer as an efficient, robust and user-friendly graphical tool for the identification of CNA/AI in the context of whole-exome sequencing data.

  7. An analytical and experimental investigation of the response of the curved, composite frame/skin specimens

    NASA Technical Reports Server (NTRS)

    Moas, Eduardo; Boitnott, Richard L.; Griffin, O. Hayden, Jr.

    1994-01-01

    Six-foot diameter, semicircular graphite/epoxy specimens representative of generic aircraft frames were loaded quasi-statistically to determine their load response and failure mechanisms for large deflections that occur in airplanes crashes. These frame/skin specimens consisted of a cylindrical skin section co-cured with a semicircular I-frame. The skin provided the necessary lateral stiffness to keep deformations in the plane of the frame in order to realistically represent deformations as they occur in actual fuselage structures. Various frame laminate stacking sequences and geometries were evaluated by statically loading the specimen until multiple failures occurred. Two analytical methods were compared for modeling the frame/skin specimens: a two-dimensional shell finite element analysis and a one-dimensional, closed-form, curved beam solution derived using an energy method. Flange effectivities were included in the beam analysis to account for the curling phenomenon that occurs in thin flanges of curved beams. Good correlation was obtained between experimental results and the analytical predictions of the linear response of the frames prior to the initial failure. The specimens were found to be useful for evaluating composite frame designs.

  8. THE INFLUENCE OF SCREW TYPE, ALLOY AND CYLINDER POSITION ON THE MARGINAL FIT OF IMPLANT FRAMEWORKS BEFORE AND AFTER LASER WELDING

    PubMed Central

    Castilio, Daniela; Pedreira, Ana Paula Ribeiro do Vale; Rossetti, Paulo Henrique Orlato; Rossetti, Leylha Maria Nunes; Bonachela, Wellington Cardoso

    2006-01-01

    Misfit at the abutment-prosthetic cylinder interface can cause loss of preload, leading to loosening or fracture of gold and titanium screws. Objectives: To evaluate the influence of screw type, alloy, and cylinder position on marginal fit of implant frameworks before and after laser welding. Methods: After Estheticone-like abutments were screwed to the implants, thirty plastic prosthetic cylinders were mounted and waxed-up to fifteen cylindrical bars. Each specimen had three interconnected prosthetic components. Five specimens were one-piece cast in titanium and five in cobalt-chromium alloy. On each specimen, tests were conducted with hexagonal titanium and slotted gold screws separately, performing a total of thirty tested screws. Measurements at the interfaces were performed using an optical microscope with 5 μm accuracy. After sectioning, specimens were laser welded and new measurements were obtained. Data were submitted to a four-way ANOVA and Tukey's multiple comparisons test (α =0.05). Results: Slotted and hexagonal screws did not present significant differences regarding to the fit of cylinders cast in titanium, either in one-piece casting framework or after laser welding. When slotted and hexagonal screws were tested on the cobalt-chromium specimens, statistically significant differences were found for the one-piece casting condition, with the slotted screws presenting better fit (24.13μm) than the hexagonal screws (27.93 μm). Besides, no statistically significant differences were found after laser welding. Conclusions: 1) The use of different metal alloys do exert influence on the marginal fit, 2) The slotted and hexagonal screws play the exclusive role of fixing the prosthesis, and did not improve the fit of cylinders, and 3) cylinder position did not affect marginal fit values. PMID:19089035

  9. Effects of Laboratory Disinfecting Agents on Dimensional Stability of Three Commercially Available Heat-Cured Denture Acrylic Resins in India: An In-Vitro Study

    PubMed Central

    Jujare, Ravikanth Haridas; Varghese, Rana Kalappattil; Singh, Vishwa Deepak; Gaurav, Amit

    2016-01-01

    Introduction Dental professionals are exposed to a wide variety of microorganisms which calls for use of effective infection control procedures in the dental office and laboratories that can prevent cross-contamination that could extend to dentists, dental office staff, dental technicians as well as patients. This concern has led to a renewed interest in denture sterilization and disinfection. Heat polymerized dentures exhibit dimensional change during disinfection procedure. Aim The purpose of this study was to determine the influence of different types of widely used laboratory disinfecting agents on the dimensional stability of heat-cured denture acrylic resins and to compare the dimensional stability of three commercially available heat-cured denture acrylic resins in India. Materials and Methods Twelve specimens of uniform dimension each of three different brands namely Stellon, Trevalon and Acralyn-H were prepared using circular metal disc. Chemical disinfectants namely 2% alkaline glutaraldehyde, 1% povidone-iodine, 0.5% sodium hypochlorite and water as control group were used. Diameter of each specimen was measured before immersion and after immersion with time interval of 1 hour and 12 hours. The data was evaluated statistically using one way analysis of variance. Results All the specimens in three disinfectants and in water exhibited very small amount of linear expansion. Among three disinfectants, specimens in 2% alkaline glutaraldehyde exhibited least(0.005mm) and water showed highest (0.009mm) amount of dimensional change. Among resins, Trevalon showed least (0.067mm) and Acralyn-H exhibited highest (0.110mm) amount of dimensional change. Conclusion Although, all the specimens of three different brands of heat-cured denture acrylic resins exhibited increase in linear dimensional change in all the disinfectants and water, they were found to be statistically insignificant. PMID:27134996

  10. Influence of various bonding techniques on the fracture strength of thin CAD/CAM-fabricated occlusal glass-ceramic veneers.

    PubMed

    Yazigi, Christine; Kern, Matthias; Chaar, Mohamed Sad

    2017-11-01

    To evaluate the efficiency of immediate dentin sealing and the effects of different bonding protocols on the fracture strength of CAD/CAM occlusal veneers bonded to exposed dentin. Ninety-six extracted maxillary premolars were initially divided into three main groups with 32 specimens each: without immediate dentin sealing, immediate dentin sealing/total etching and immediate dentin sealing/selective etching. Teeth were identically prepared in the dentin to receive occlusal veneers of 0.8mm thickness, milled from lithium disilicate ceramic blocks (IPS e.max CAD). Each main group was later subdivided, according to the pre-cementation surface etching protocol (total/selective), into two subgroups with 16 specimens each. All restorations were adhesively bonded using a resin cement (Variolink Esthetic). Half of the specimens of each subgroup were subjected to thermo-dynamic loading in a chewing simulator with 1,200,000 cycles at 10kg load. The other half and the surviving specimens were subjected to quasi-static loading until failure. Statistical analysis was performed using three-way ANOVA and Tukey's post-hoc tests. All specimens except one survived the artificial aging. A significantly higher fracture strength of restorations (p ≤ 0.001) was obtained when immediate dentin sealing was followed regardless of the etching method with values ranging from a minimum of 1122 ± 336N to a maximum of 1853 ± 333N. Neither the pre-cementation treatment nor the artificial aging had a statistical significant effect on the fracture strength. Immediate dentin sealing protocol is recommended whenever dentin is exposed during the preparation for thin glass-ceramic occlusal veneers. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Influence of hydrostatic pulpal pressure on the microtensile bond strength of all-in-one self-etching adhesives.

    PubMed

    Hosaka, Keiichi; Nakajima, Masatoshi; Monticelli, Francesca; Carrilho, Marcela; Yamauti, Monica; Aksornmuang, Juthatip; Nishitani, Yoshihiro; Tay, Franklin R; Pashley, David H; Tagami, Junji

    2007-10-01

    To evaluate the microtensile bond strength (microTBS) of two all-in-one self-etching adhesive systems and two self-etching adhesives with and without simulated hydrostatic pulpal pressure (PP). Flat coronal dentin surfaces of extracted human molars were prepared. Two all-in-one self-etching adhesive systems, One-Up Bond F (OBF; Tokuyama) and Clearfil S3 Bond (Tri-S, Kuraray Medical) and two self-etching primer adhesives, Clearfil Protect Bond (PB; Kuraray) and Clearfil SE Bond (SE; Kuraray) were applied to the dentin surfaces according to manufacturers' instructions under either a pulpal pressure (PP) of zero or 15 cm H2O. A hybrid resin composite (Clearfil AP-X, Kuraray) was used for the coronal buildup. Specimens bonded under PP were stored in water at 37 degrees C under 15 cm H2O for 24 h. Specimens not bonded under PP were stored under a PP of zero. After storage, the bonded specimens were sectioned into slabs that were trimmed to hourglass-shaped specimens, and were subjected to microtensile bond testing (microTBS). The bond strength data were statistically analyzed using two-way ANOVA and the Holm-Sidak method for multiple comparison tests (alpha = 0.05). The surface area percentage of different failure modes for each material was also statistically analyzed with three one-way ANOVAs and Tukey's multiple comparison tests. The microTBS of OBF and Tri-S fell significantly under PP. However, in the, PB and SE bonded specimens under PP, there were no significant differences compared with the control groups without PP. The microTBS of the two all-in-one adhesive systems decreased when PP was applied. However, the microTBS of both self-etching primer adhesives did not decrease under PP.

  12. Effect of surface treatments on shear bond strength of resin composite bonded to CAD/CAM resin-ceramic hybrid materials

    PubMed Central

    Güngör, Merve Bankoğlu; Bal, Bilge Turhan; Ünver, Senem; Doğan, Aylin

    2016-01-01

    PURPOSE The purpose of this study was to assess the effect of surface treatments on shear bond strength of resin composite bonded to thermocycled and non-thermocycled CAD/CAM resin-ceramic hybrid materials. MATERIALS AND METHODS 120 specimens (10×10×2 mm) from each material were divided into 12 groups according to different surface treatments in combination with thermal aging procedures. Surface treatment methods were airborne-particle abrasion (abraded with 50 micron alumina particles), dry grinding (grinded with 125 µm grain size bur), and hydrofluoric acid (9%) and silane application. According to the thermocycling procedure, the groups were assigned as non-thermocycled, thermocycled after packing composites, and thermocycled before packing composites. The average surface roughness of the non-thermocycled specimens were measured after surface treatments. After packing composites and thermocycling procedures, shear bond strength (SBS) of the specimens were tested. The results of surface roughness were statistically analyzed by 2-way Analysis of Variance (ANOVA), and SBS results were statistically analyzed by 3-way ANOVA. RESULTS Surface roughness of GC were significantly lower than that of LU and VE (P<.05). The highest surface roughness was observed for dry grinding group, followed by airborne particle abraded group (P<.05). Comparing the materials within the same surface treatment method revealed that untreated surfaces generally showed lower SBS values. The values of untreated LU specimens showed significantly different SBS values compared to those of other surface treatment groups (P<.05). CONCLUSION SBS was affected by surface treatments. Thermocycling did not have any effect on the SBS of the materials except acid and silane applied GC specimens, which were subjected to thermocycling before packing of the composite resin. PMID:27555894

  13. Flexural strength and failure modes of layered ceramic structures.

    PubMed

    Borba, Márcia; de Araújo, Maico D; de Lima, Erick; Yoshimura, Humberto N; Cesar, Paulo F; Griggs, Jason A; Della Bona, Alvaro

    2011-12-01

    To evaluate the effect of the specimen design on the flexural strength (σ(f)) and failure mode of ceramic structures, testing the hypothesis that the ceramic material under tension controls the mechanical performance of the structure. Three ceramics used as framework materials for fixed partial dentures (YZ--Vita In-Ceram YZ; IZ--Vita In-Ceram Zirconia; AL--Vita In-Ceram AL) and two veneering porcelains (VM7 and VM9) were studied. Bar-shaped specimens were produced in three different designs (n=10): monolithic, two layers (porcelain-framework) and three layers (TRI) (porcelain-framework-porcelain). Specimens were tested for three-point flexural strength at 1MPa/s in 37°C artificial saliva. For bi-layered design, the specimens were tested in both conditions: with porcelain (PT) or framework ceramic (FT) layer under tension. Fracture surfaces were analyzed using stereomicroscope and scanning electron microscopy (SEM). Young's modulus (E) and Poisson's ratio (ν) were determined using ultrasonic pulse-echo method. Results were statistically analyzed by Kruskal-Wallis and Student-Newman-Keuls tests. Except for VM7 and VM9, significant differences were observed for E values among the materials. YZ showed the highest ν value followed by IZ and AL. YZ presented the highest σ(f). There was no statistical difference in the σ(f) value between IZ and IZ-FT and between AL and AL-FT. σ(f) values for YZ-PT, IZ-PT, IZ-TRI, AL-PT, AL-TRI were similar to the results obtained for VM7 and VM9. Two types of fracture mode were identified: total and partial failure. The mechanical performance of the specimens was determined by the material under tension during testing, confirming the study hypothesis. Copyright © 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  14. The influence of screw type, alloy and cylinder position on the marginal fit of implant frameworks before and after laser welding.

    PubMed

    Castilio, Daniela; Pedreira, Ana Paula Ribeiro do Vale; Rossetti, Paulo Henrique Orlato; Rossetti, Leylha Maria Nunes; Bonachela, Wellington Cardoso

    2006-04-01

    Misfit at the abutment-prosthetic cylinder interface can cause loss of preload, leading to loosening or fracture of gold and titanium screws. To evaluate the influence of screw type, alloy, and cylinder position on marginal fit of implant frameworks before and after laser welding. After Estheticone-like abutments were screwed to the implants, thirty plastic prosthetic cylinders were mounted and waxed-up to fifteen cylindrical bars. Each specimen had three interconnected prosthetic components. Five specimens were one-piece cast in titanium and five in cobalt-chromium alloy. On each specimen, tests were conducted with hexagonal titanium and slotted gold screws separately, performing a total of thirty tested screws. Measurements at the interfaces were performed using an optical microscope with 5mm accuracy. After sectioning, specimens were laser welded and new measurements were obtained. Data were submitted to a four-way ANOVA and Tukey's multiple comparisons test (alpha=0.05). Slotted and hexagonal screws did not present significant differences regarding to the fit of cylinders cast in titanium, either in one-piece casting framework or after laser welding. When slotted and hexagonal screws were tested on the cobalt-chromium specimens, statistically significant differences were found for the one-piece casting condition, with the slotted screws presenting better fit (24.13 microm) than the hexagonal screws (27.93 microm). Besides, no statistically significant differences were found after laser welding. 1) The use of different metal alloys do exert influence on the marginal fit, 2) The slotted and hexagonal screws play the exclusive role of fixing the prosthesis, and did not improve the fit of cylinders, and 3) cylinder position did not affect marginal fit values.

  15. Prospective Evaluation Of Cervico-Vaginal Self And Cervical Physician-Collection For The Detection Of Chlamydia Trachomatis, Neisseria Gonorrhoeae, Trichomonas Vaginalis, And Mycoplasma Genitalium Infections.

    PubMed

    Lockhart, Alexandre; Psioda, Matt; Ting, Jie; Campbell, Sara; Mugo, Nelly; Kwatampora, Jessie; Chitwa, Michael; Kimani, Joshua; Gakure, Anne; Smith, Jennifer S

    2018-01-02

    To examine the agreement between sexually transmitted infection (STI) screening using self-collected specimens and physician-collected specimens, and to investigate the acceptability of self-collection for screening in an 18-month study of female sex-workers (FSW) in a high-risk, low-resource setting. A total of 350 FSW in Nairobi, Kenya participated in a prospective study from 2009-2011. Women self-collected a cervico-vaginal specimen. Next, a physician conducted a pelvic examination to obtain a cervical specimen. Physician- and self-collected specimens were tested for Chlamydia trachomatis (CT), Neisseria gonorrhoeae (GC), Trichomonas vaginalis (TV) and Mycoplasma genitalium (MG) using Aptima nucleic acid amplification assays (Hologic). Specimens were collected at three-month intervals over 18-months follow-up. Kappa statistics measured agreement of positivity between self- and physician-collection. Baseline STI prevalence was 2.9% for GC, 5.2% for CT, 9.2% for TV, and 20.1% for MG in self-collected samples, and 2.3%, 3.7%, 7.2%, and 12.9% respectively in physician-collected samples. Kappa agreement was consistently strong (range 0.66-1.00) for all STIs over the 18-month study period, except MG which had moderate agreement (range: 0.50-0.75). Most participants found self-collection easy (94%) and comfortable (89%) at baseline, with responses becoming modestly more favorable over time. Self-collected specimens screening results showed strong agreement to clinical-collected specimens, except MG which was consistently detected more commonly in self- than physician-collected specimens. Acceptability of the self-collection procedure was high at baseline and increased modestly over time. In high-risk, low-resource settings, STI screening with self-collected specimens provides a reliable and acceptable alternative to screening with physician-collected specimens.

  16. A Brief Review of the Lithology and Petrology of the Tagish Lake Meteorite Type Specimen

    NASA Astrophysics Data System (ADS)

    Herd, R. K.

    2009-05-01

    The mineralogical and textural characteristics of the type specimen of the Tagish Lake meteorite were described previously [1,2]. These initial descriptions recognized two lithologies, one relatively carbonate-poor, and the other relatively carbonate-rich. In addition numerous lithic fragments within the main lithologies were noted, essentially brecciated fragments within brecciated fragments [2,3]. Most research on the meteorite has generally assumed that only two lithologies were present. Many preliminary mineral and organic analyses done on pristine and non-pristine samples cannot be related to a particular matrix -- neither to the two supposed to be present, nor to any others. Distinction has sometimes been made between chondrule-bearing lithologies or fragments, and non-chondrule-bearing, or so-called dark dusty, lithologies preserved in the pristine specimen suite. To aid in a systematic approach to understanding this unique meteorite, the main petrographic features of the type specimen polished section are reviewed, based on back-scattered electron (BSE) images and electron- microprobe (EM) analyses. What is still needed is a consortium study of the pristine and non-pristine samples, that would define all the lithologies present and their inter-relationships, within the complete specimen suite, as the context and framework for ongoing research. [1] Brown, P.G. et al. (2000) Science, 290, 320-325. [2] Herd, R.K. et al. (2001) LPS XXXII, Abstract 1928. [3] Herd, R.K. and Herd, C.D.K. (2007) LPS XXXVIII, Abstract 2347.

  17. A statistical comparison of two carbon fiber/epoxy fabrication techniques

    NASA Technical Reports Server (NTRS)

    Hodge, A. J.

    1991-01-01

    A statistical comparison of the compression strengths of specimens that were fabricated by either a platen press or an autoclave were performed on IM6/3501-6 carbon/epoxy composites of 16-ply (0,+45,90,-45)(sub S2) lay-up configuration. The samples were cured with the same parameters and processing materials. It was found that the autoclaved panels were thicker than the platen press cured samples. Two hundred samples of each type of cure process were compression tested. The autoclaved samples had an average strength of 450 MPa (65.5 ksi), while the press cured samples had an average strength of 370 MPa (54.0 ksi). A Weibull analysis of the data showed that there is only a 30 pct. probability that the two types of cure systems yield specimens that can be considered from the same family.

  18. Effects of different surface treatments and accelerated artificial aging on the bond strength of composite resin repairs.

    PubMed

    Melo, Marco Aurélio Veiga de; Moysés, Marcos Ribeiro; Santos, Saulo Galvão dos; Alcântara, Carlos Eduardo Pinto; Ribeiro, José Carlos Rabelo

    2011-01-01

    The purpose of the present study was to assess the bond strength of composite resin repairs subjected to different surface treatments and accelerated artificial aging. 192 cylindrical samples (CSs) were prepared and divided into 24 groups (n = 8). Half of the CSs were stored in water for 24 h, and the other half were subjected to C-UV accelerated aging for non-metallic specimens. The treatments were phosphoric acid + silane + adhesive (PSA); phosphoric acid + adhesive (PA); diamond bur + phosphoric acid + silane + adhesive (DPSA); diamond bur + phosphoric acid + adhesive (DPA); air abrasion + phosphoric acid + silane + adhesive (APSA); and air abrasion + phosphoric acid + adhesive (APA). The repair was performed and the specimens were again aged as described above. A control group (n = 8) was established and did not receive any type of aging or surface treatment. The specimens were loaded to failure in shear mode with a crosshead speed of 0.5 mm/min until fracture. Data were analyzed by one-way ANOVA/Tukey's test (p < 0.05). No statistically significant differences were found among DPSA, DPA, APSA, APA, and the control group. The aged PSA and PA achieved low bonding values and were statistically different from the control group, whereas the non-aged PSA and PA presented no statistically significant difference from the control group. Repairs with the proposed surface treatments were viable on both recent and aged restorations; however, phosphoric acid + adhesive alone were effective only on recent restorations.

  19. Effects of surface-finishing protocols on the roughness, color change, and translucency of different ceramic systems.

    PubMed

    Akar, Gülcan Coşkun; Pekkan, Gürel; Çal, Ebru; Eskitaşçıoğlu, Gürcan; Özcan, Mutlu

    2014-08-01

    Surface-finishing protocols have a mechanical impact on ceramic surfaces that could eventually affect surface topography and light scattering. An optimum protocol is needed to avoid damaging the optical properties of ceramics. The purpose of this study was to determine the effects of different surface-finishing protocols on the surface roughness, color change, and translucency of ceramic and metal ceramic restorations. Standardized disk-shaped specimens (1.5 × 10 mm, n=128) were fabricated from 3 different ceramic core materials (aluminum oxide [Al2O3]-AL, zirconium oxide [ZrO2]-ZR, lithium disilicate [Li2Si2O5]-LIT), veneered (V) with dentin ceramics (n=32 per group), and placed in the following groups: ALV, ZRV, and LITV. The metal ceramic group acted as the control (n=32). Four different surface-finishing methods were tested. Airborne-particle abrasion with 50 μm Al2O3, polishing with adjustment kit, polishing with adjustment kit plus diamond polishing paste, and autoglazing (n=8 subgroup) were applied on the veneering ceramics. The specimens were analyzed with a profilometer for surface roughness, and color change and translucency were measured with a clinical spectrophotometer. Statistical analyses were performed with 1-way ANOVA and the Tukey honest significant difference tests (α=.05). Specimens treated with the airborne particle abrasion method showed significantly higher mean profilometer for surface roughness values in all groups (P<.05). The polishing with adjustment kit and autoglazing methods revealed statistically similar surface roughness values in all groups (P>.05). With the diamond polishing paste method, lower surface roughness values were achieved in the ZRV and metal ceramic groups acted as the control groups. Different surface-finishing methods affected the color change of the ceramic systems, except for ZRV. Surface-finishing protocols significantly affected the translucency values of the ALV, LITV, and metal ceramic groups (P<.05). No single surface-finishing protocol can be recommended to obtain the smoothest surface and the least color change without affecting translucency for the ceramics tested. The airborne-particle abrasion protocol created rougher surfaces and decreased translucency, and color change in zirconia was not affected by the finishing protocols. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. Analysing the influence of FSP process parameters on IGC susceptibility of AA5083 using Sugeno - Fuzzy model

    NASA Astrophysics Data System (ADS)

    Jayakarthick, C.; Povendhan, A. P.; Vaira Vignesh, R.; Padmanaban, R.

    2018-02-01

    Aluminium alloy AA5083 was friction stir processed to improve the intergranular corrosion (IGC) resistance. FSP trials were performed by varying the process parameters as per Taguchi’s L18 orthogonal array. IGC resistance of the friction stir processed specimens were found by immersing them in concentrated nitric acid and measuring the mass loss per unit area. Results indicate that dispersion and partial dissolution of secondary phase increased IGC resistance of the friction stir processed specimens. A Sugeno fuzzy model was developed to study the effect of FSP process parameters on the IGC susceptibility of friction stir processed specimens. Tool Rotation Speed, Tool Traverse Speed and Shoulder Diameter have a significant effect on the IGC susceptibility of the friction stir processed specimens.

  1. Effect of compression load and temperature on thermomechanical tests for gutta-percha and Resilon®.

    PubMed

    Tanomaru-Filho, M; Silveira, G F; Reis, J M S N; Bonetti-Filho, I; Guerreiro-Tanomaru, J M

    2011-11-01

    To analyse a method used to evaluate the thermomechanical properties of gutta-percha and Resilon(®) at different temperatures and compression loads. Two hundred and seventy specimens measuring 10 mm in diameter and 1.5 mm in height were made from the following materials: conventional gutta-percha (GCO), thermoplastic gutta-percha (GTP) and Resilon(®) cones (RE). After 24 h, the specimens were placed in water at 50 °C, 60 °C or 70 °C for 60 s. After that, specimens were placed between two glass slabs, and loads weighing 1.0, 3.0 or 5.0 kg were applied. Images of the specimens were digitized before and after the test and analysed using imaging software to determine their initial and final areas. The thermomechanical property of each material was determined by the difference between the initial and final areas of the specimens. Data were subjected to anova and SNK tests at 5% significance. To verify a possible correlation between the results of the materials, linear regression coefficients (r) were calculated. Data showed higher flow area values for RE under all compression loads at 70 °C and under the 5.0 kg load at 60 °C (P < 0.05). Regarding gutta-percha, GTP showed higher flow under loads weighing 3.0 and 5.0 kg, at 60 and 70 °C (P < 0.05). GCO presented higher flow at 70 °C with a load of 5.0 kg. Regression analyses showed a poor linear correlation amongst the results of the materials under the different experimental conditions. Gutta-percha and Resilon(®) cones require different compression loads and temperatures for evaluation of their thermomechanical properties. For all materials, the greatest flow occurred at 70 °C under a load of 5.0 kg; therefore, these parameters may be adopted when evaluating endodontic filling materials. © 2011 International Endodontic Journal.

  2. Sampling designs for contaminant temporal trend analyses using sedentary species exemplified by the snails Bellamya aeruginosa and Viviparus viviparus.

    PubMed

    Yin, Ge; Danielsson, Sara; Dahlberg, Anna-Karin; Zhou, Yihui; Qiu, Yanling; Nyberg, Elisabeth; Bignert, Anders

    2017-10-01

    Environmental monitoring typically assumes samples and sampling activities to be representative of the population being studied. Given a limited budget, an appropriate sampling strategy is essential to support detecting temporal trends of contaminants. In the present study, based on real chemical analysis data on polybrominated diphenyl ethers in snails collected from five subsites in Tianmu Lake, computer simulation is performed to evaluate three sampling strategies by the estimation of required sample size, to reach a detection of an annual change of 5% with a statistical power of 80% and 90% with a significant level of 5%. The results showed that sampling from an arbitrarily selected sampling spot is the worst strategy, requiring much more individual analyses to achieve the above mentioned criteria compared with the other two approaches. A fixed sampling site requires the lowest sample size but may not be representative for the intended study object e.g. a lake and is also sensitive to changes of that particular sampling site. In contrast, sampling at multiple sites along the shore each year, and using pooled samples when the cost to collect and prepare individual specimens are much lower than the cost for chemical analysis, would be the most robust and cost efficient strategy in the long run. Using statistical power as criterion, the results demonstrated quantitatively the consequences of various sampling strategies, and could guide users with respect of required sample sizes depending on sampling design for long term monitoring programs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. A Multiscale Progressive Failure Modeling Methodology for Composites that Includes Fiber Strength Stochastics

    NASA Technical Reports Server (NTRS)

    Ricks, Trenton M.; Lacy, Thomas E., Jr.; Bednarcyk, Brett A.; Arnold, Steven M.; Hutchins, John W.

    2014-01-01

    A multiscale modeling methodology was developed for continuous fiber composites that incorporates a statistical distribution of fiber strengths into coupled multiscale micromechanics/finite element (FE) analyses. A modified two-parameter Weibull cumulative distribution function, which accounts for the effect of fiber length on the probability of failure, was used to characterize the statistical distribution of fiber strengths. A parametric study using the NASA Micromechanics Analysis Code with the Generalized Method of Cells (MAC/GMC) was performed to assess the effect of variable fiber strengths on local composite failure within a repeating unit cell (RUC) and subsequent global failure. The NASA code FEAMAC and the ABAQUS finite element solver were used to analyze the progressive failure of a unidirectional SCS-6/TIMETAL 21S metal matrix composite tensile dogbone specimen at 650 degC. Multiscale progressive failure analyses were performed to quantify the effect of spatially varying fiber strengths on the RUC-averaged and global stress-strain responses and failure. The ultimate composite strengths and distribution of failure locations (predominately within the gage section) reasonably matched the experimentally observed failure behavior. The predicted composite failure behavior suggests that use of macroscale models that exploit global geometric symmetries are inappropriate for cases where the actual distribution of local fiber strengths displays no such symmetries. This issue has not received much attention in the literature. Moreover, the model discretization at a specific length scale can have a profound effect on the computational costs associated with multiscale simulations.models that yield accurate yet tractable results.

  4. Effect of laser welding on the titanium composite tensile bond strength.

    PubMed

    Galo, Rodrigo; Ribeiro, Ricardo Faria; Rodrigues, Renata Cristina Silveira; Pagnano, Valéria de Oliveira; de Mattos, Maria da Glória Chiarello

    2009-01-01

    The aim of this study was to analyze the shear bond strength between commercially pure titanium, with and without laser welding, after airbone-particle abrasion (Al(2)O(3)) and 2 indirect composites. Sixty-four specimens were cast and divided into 2 groups with and without laser welding. Each group was divided in 4 subgroups, related to Al(2)O(3) grain size: A - 250 microm; B - 180 microm; C- 110 microm; and D - 50 microm. Composite rings were formed around the rods and light polymerized using UniXS unit. Specimens were invested and their shear bond strength at failure was measured with a universal testing machine at a crosshead speed of 2.0 mm/min. Statistical analysis was carried out with ANOVA and Tukey's test (alpha=0.05). The highest bond strength means were recorded in 250 microm group without laser welding. The lowest shear bond strength means were recorded in 50 microm group with laser welding. Statistically significant differences (p<0.05) were found between all groups. In conclusion, airborne particle abrasion yielded significantly lower bond strength as the Al(2)O(3) particle size decreased. Shear bond strength decreased in the laser welded specimens.

  5. Single-screw Fixation of Adolescent Salter-II Proximal Humeral Fractures: Biomechanical Analysis of the "One Pass Door Lock" Technique.

    PubMed

    Miller, Mark Carl; Redman, Christopher N; Mistovich, R Justin; Muriuki, Muturi; Sangimino, Mark J

    2017-09-01

    Pin fixation of Salter-II proximal humeral fractures in adolescents approaching skeletal maturity has potential complications that can be avoided with single-screw fixation. However, the strength of screw fixation relative to parallel and diverging pin fixation is unknown. To compare the biomechanical fixation strength between these fixation modalities, we used synthetic composite humeri, and then compared these results in composite bone with cadaveric humeri specimens. Parallel pinning, divergent pinning, and single-screw fixation repairs were performed on synthetic composite humeri with simulated fractures. Six specimens of each type were tested in axial loading and other 6 were tested in torsion. Five pair of cadaveric humeri were tested with diverging pins and single screws for comparison. Single-screw fixation was statistically stronger than pin fixation in axial and torsional loading in both composite and actual bone. There was no statistical difference between composite and cadaveric bone specimens. Single-screw fixation can offer greater stability to adolescent Salter-II fractures than traditional pinning. Single-screw fixation should be considered as a viable alternative to percutaneous pin fixation in transitional patients with little expected remaining growth.

  6. Limited Utility of Polymerase Chain Reaction in Induced Sputum Specimens for Determining the Causes of Childhood Pneumonia in Resource-Poor Settings: Findings From the Pneumonia Etiology Research for Child Health (PERCH) Study

    PubMed Central

    Seidenberg, Phil; Park, Daniel E.; Mwananyanda, Lawrence; Fu, Wei; Shi, Qiyuan; Baggett, Henry C.; Brooks, W. Abdullah; Feikin, Daniel R.; Howie, Stephen R.C.; Knoll, Maria Deloria; Kotloff, Karen L.; Levine, Orin S.; Madhi, Shabir A.; O’Brien, Katherine L.; Scott, J. Anthony G.; Antonio, Martin; Awori, Juliet O.; Baillie, Vicky L.; DeLuca, Andrea N.; Driscoll, Amanda J.; Higdon, Melissa M.; Hossain, Lokman; Jahan, Yasmin; Karron, Ruth A.; Kazungu, Sidi; Li, Mengying; Moore, David P.; Morpeth, Susan C.; Ofordile, Ogochukwu; Prosperi, Christine; Sangwichian, Ornuma; Sawatwong, Pongpun; Sylla, Mamadou; Tapia, Milagritos D.; Zeger, Scott L.; Murdoch, David R.; Hammitt, Laura L.; O., K. L.; L., O. S.; K., M. D.; F., D. R.; D., A. N.; D., A. J.; Fancourt, Nicholas; F., W.; H., L. L.; H., M. M.; Wangeci Kagucia, E.; K., R. A.; L., M.; P., D. E.; P., C.; Wu, Zhenke; Z., S. L.; Watson, Nora L.; Crawley, Jane; M., D. R.; W. A., B.; Endtz, Hubert P.; Khalequ, Zaman; Goswami, Doli; H., L.; J., Y.; Ashraf, Hasan; H., S. R. C.; Ebruke, Bernard E.; A., M.; McLellan, Jessica; Machuka, Eunice; Shamsul, Arifin; Zaman, Syed M. A.; Mackenzie, Grant; S., J. A. G.; A., J. O.; M., S. C.; Kamau, Alice; K., S.; Ominde, Micah Silaba; K., K. L.; T., M. D.; Sow, Samba O.; S., M.; Tamboura, Boubou; Onwuchekwa, Uma; Kourouma, Nana; Toure, Aliou; M., S. A.; M., D. P.; Adrian, Peter V.; B., V. L.; Kuwanda, Locadiah; Mudau, Azwifarwi; Groome, Michelle J.; Mahomed, Nasreen; B., H. C.; Thamthitiwat, Somsak; Maloney, Susan A.; Bunthi, Charatdao; Rhodes, Julia; S., P.; Akarasewi, Pasakorn; T., D. M.; M., L.; Chipeta, James; S., P.; Mwansa, James; wa Somwe, Somwe; Kwenda, Geoffrey; Anderson, Trevor P.; Mitchell, Joanne

    2017-01-01

    Abstract Background. Sputum examination can be useful in diagnosing the cause of pneumonia in adults but is less well established in children. We sought to assess the diagnostic utility of polymerase chain reaction (PCR) for detection of respiratory viruses and bacteria in induced sputum (IS) specimens from children hospitalized with severe or very severe pneumonia. Methods. Among children aged 1–59 months, we compared organism detection by multiplex PCR in IS and nasopharyngeal/oropharyngeal (NP/OP) specimens. To assess whether organism presence or density in IS specimens was associated with chest radiographic evidence of pneumonia (radiographic pneumonia), we compared prevalence and density in IS specimens from children with radiographic pneumonia and children with suspected pneumonia but without chest radiographic changes or clinical or laboratory findings suggestive of pneumonia (nonpneumonia group). Results. Among 4232 cases with World Health Organization–defined severe or very severe pneumonia, we identified 1935 (45.7%) with radiographic pneumonia and 573 (13.5%) with nonpneumonia. The organism detection yield was marginally improved with IS specimens (96.2% vs 92.4% for NP/OP specimens for all viruses combined [P = .41]; 96.9% vs 93.3% for all bacteria combined [P = .01]). After accounting for presence in NP/OP specimens, no organism was detected more frequently in the IS specimens from the radiographic pneumonia compared with the nonpneumonia cases. Among high-quality IS specimens, there were no statistically significant differences in organism density, except with cytomegalovirus, for which there was a higher quantity in the IS specimens from cases with radiographic pneumonia compared with the nonpneumonia cases (median cycle threshold value, 27.9 vs 28.5, respectively; P = .01). Conclusions. Using advanced molecular methods with IS specimens provided little additional diagnostic information beyond that obtained with NP/OP swab specimens. PMID:28575363

  7. Limited Utility of Polymerase Chain Reaction in Induced Sputum Specimens for Determining the Causes of Childhood Pneumonia in Resource-Poor Settings: Findings From the Pneumonia Etiology Research for Child Health (PERCH) Study.

    PubMed

    Thea, Donald M; Seidenberg, Phil; Park, Daniel E; Mwananyanda, Lawrence; Fu, Wei; Shi, Qiyuan; Baggett, Henry C; Brooks, W Abdullah; Feikin, Daniel R; Howie, Stephen R C; Knoll, Maria Deloria; Kotloff, Karen L; Levine, Orin S; Madhi, Shabir A; O'Brien, Katherine L; Scott, J Anthony G; Antonio, Martin; Awori, Juliet O; Baillie, Vicky L; DeLuca, Andrea N; Driscoll, Amanda J; Higdon, Melissa M; Hossain, Lokman; Jahan, Yasmin; Karron, Ruth A; Kazungu, Sidi; Li, Mengying; Moore, David P; Morpeth, Susan C; Ofordile, Ogochukwu; Prosperi, Christine; Sangwichian, Ornuma; Sawatwong, Pongpun; Sylla, Mamadou; Tapia, Milagritos D; Zeger, Scott L; Murdoch, David R; Hammitt, Laura L

    2017-06-15

    Sputum examination can be useful in diagnosing the cause of pneumonia in adults but is less well established in children. We sought to assess the diagnostic utility of polymerase chain reaction (PCR) for detection of respiratory viruses and bacteria in induced sputum (IS) specimens from children hospitalized with severe or very severe pneumonia. Among children aged 1-59 months, we compared organism detection by multiplex PCR in IS and nasopharyngeal/oropharyngeal (NP/OP) specimens. To assess whether organism presence or density in IS specimens was associated with chest radiographic evidence of pneumonia (radiographic pneumonia), we compared prevalence and density in IS specimens from children with radiographic pneumonia and children with suspected pneumonia but without chest radiographic changes or clinical or laboratory findings suggestive of pneumonia (nonpneumonia group). Among 4232 cases with World Health Organization-defined severe or very severe pneumonia, we identified 1935 (45.7%) with radiographic pneumonia and 573 (13.5%) with nonpneumonia. The organism detection yield was marginally improved with IS specimens (96.2% vs 92.4% for NP/OP specimens for all viruses combined [P = .41]; 96.9% vs 93.3% for all bacteria combined [P = .01]). After accounting for presence in NP/OP specimens, no organism was detected more frequently in the IS specimens from the radiographic pneumonia compared with the nonpneumonia cases. Among high-quality IS specimens, there were no statistically significant differences in organism density, except with cytomegalovirus, for which there was a higher quantity in the IS specimens from cases with radiographic pneumonia compared with the nonpneumonia cases (median cycle threshold value, 27.9 vs 28.5, respectively; P = .01). Using advanced molecular methods with IS specimens provided little additional diagnostic information beyond that obtained with NP/OP swab specimens. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  8. Polymorphisms and allele frequencies of the ABO blood group gene among the Jomon, Epi-Jomon and Okhotsk people in Hokkaido, northern Japan, revealed by ancient DNA analysis.

    PubMed

    Sato, Takehiro; Kazuta, Hisako; Amano, Tetsuya; Ono, Hiroko; Ishida, Hajime; Kodera, Haruto; Matsumura, Hirofumi; Yoneda, Minoru; Dodo, Yukio; Masuda, Ryuichi

    2010-10-01

    To investigate the genetic characteristics of the ancient populations of Hokkaido, northern Japan, polymorphisms of the ABO blood group gene were analyzed for 17 Jomon/Epi-Jomon specimens and 15 Okhotsk specimens using amplified product-length polymorphism and restriction fragment length polymorphism analyses. Five ABO alleles were identified from the Jomon/ Epi-Jomon and Okhotsk people. Allele frequencies of the Jomon/Epi-Jomon and Okhotsk people were compared with those of the modern Asian, European and Oceanic populations. The genetic relationships inferred from principal component analyses indicated that both Jomon/Epi-Jomon and Okhotsk people are included in the same group as modern Asian populations. However, the genetic characteristics of these ancient populations in Hokkaido were significantly different from each other, which is in agreement with the conclusions from mitochondrial DNA and ABCC11 gene analyses that were previously reported.

  9. Establishment of the onset of host specificity in four phyllobothriid tapeworm species (Cestoda: Tetraphyllidea) using a molecular approach.

    PubMed

    Randhawa, H S; Saunders, G W; Burt, M D B

    2007-08-01

    A parasitological survey in the Bay of Fundy, Canada, resulted in the recovery of mature specimens from 5 species of phyllobothriid tapeworms (Cestoda: Tetraphyllidea) from 4 rajid skates: Echeneibothrium canadensis and E. dubium abyssorum specimens from Amblyraja radiata; E. vernetae and Pseudanthobothrium n.sp. from Leucoraja erinacea and L. ocellata; and P. hanseni from A. radiata and Malacoraja senta. Partial sequence data of a variable region (D2) from the large subunit ribosomal DNA (LSU) were used here to determine the host distribution of immature specimens for 4 of these 5 species (E. d. abyssorum was not included in the analyses). Immature specimens from both Pseudanthobothrium spp. were identified in the same hosts as recorded previously for mature specimens, thus suggesting that there are mechanisms that prevent the attachment of the parasite in an 'unsuitable' host species. Immature E. canadensis specimens were recovered exclusively from A. radiata, whereas immature E. vernetae specimens were recovered from L. erinacea and A. radiata, despite the latter host species not harbouring mature E. vernetae specimens. Their presence in the latter host species may be explained by host restriction or resistance, which allows the attachment of the parasites in the 'wrong' host species, but not establishment or development.

  10. Taxonomic revision of the long-nosed armadillos, Genus Dasypus Linnaeus, 1758 (Mammalia, Cingulata)

    PubMed Central

    Patterson, Bruce D.; Cordeiro-Estrela, Pedro

    2018-01-01

    Dasypus is the most speciose genus of the order Cingulata, including approximately 40% of known living armadillos. Nine species are currently recognized, although comprehensive analyses of the entire genus have never been done. Our aim is to revise the taxonomy of the long-nosed armadillos and properly define the taxa. We examined 2126 specimens of Dasypus preserved in 39 different museum collections, including 17 type specimens. Three complementary methods were applied to explore morphological datasets both qualitatively and quantitatively. Qualitative morphological variation in discrete characters was assessed by direct observations of specimens. Linear morphometric variation was based on external data and cranial measurements of 887 adult skulls. The shape and size of the skull was abstracted through two-dimensional geometric morphometric analyses of dorsal, lateral and ventral views of respectively 421, 211, and 220 adult specimens. Our results converge on the recognition of eight living species (D. beniensis, D. kappleri, D. mazzai, D. novemcinctus, D. pastasae, D. pilosus, D. sabanicola, and D. septemcinctus), and three subspecies of D. septemcinctus (D. s. septemcinctus, D. s. hybridus, and a new subspecies from Cordoba described here). Information on type material, diagnosis, distribution, and taxonomic comments for each taxon are provided. We designate a lectotype for D. novemcinctus; and a neotype for Loricatus hybridus (= D. septemcinctus hybridus). PMID:29624590

  11. Effect of Measured Welding Residual Stresses on Crack Growth

    NASA Technical Reports Server (NTRS)

    Hampton, Roy W.; Nelson, Drew; Doty, Laura W. (Technical Monitor)

    1998-01-01

    Welding residual stresses in thin plate A516-70 steel and 2219-T87 aluminum butt weldments were measured by the strain-gage hole drilling and X-ray diffraction methods. The residual stress data were used to construct 3D strain fields which were modeled as thermally induced strains. These 3D strain fields were then analyzed with the WARP31) FEM fracture analysis code in order to predict their effect on fatigue and on fracture. For analyses of fatigue crack advance and subsequent verification testing, fatigue crack growth increments were simulated by successive saw-cuts and incremental loading to generate, as a function of crack length, effects on crack growth of the interaction between residual stresses and load induced stresses. The specimen experimental response was characterized and compared to the WARM linear elastic and elastic-plastic fracture mechanics analysis predictions. To perform the fracture analysis, the plate material's crack tearing resistance was determined by tests of thin plate M(T) specimens. Fracture analyses of these specimen were performed using WARP31D to determine the critical Crack Tip Opening Angle [CTOA] of each material. These critical CTOA values were used to predict crack tearing and fracture in the weldments. To verify the fracture predictions, weldment M(T) specimen were tested in monotonic loading to fracture while characterizing the fracture process.

  12. Temporal patterns of damage and decay kinetics of DNA retrieved from plant herbarium specimens.

    PubMed

    Weiß, Clemens L; Schuenemann, Verena J; Devos, Jane; Shirsekar, Gautam; Reiter, Ella; Gould, Billie A; Stinchcombe, John R; Krause, Johannes; Burbano, Hernán A

    2016-06-01

    Herbaria archive a record of changes of worldwide plant biodiversity harbouring millions of specimens that contain DNA suitable for genome sequencing. To profit from this resource, it is fundamental to understand in detail the process of DNA degradation in herbarium specimens. We investigated patterns of DNA fragmentation and nucleotide misincorporation by analysing 86 herbarium samples spanning the last 300 years using Illumina shotgun sequencing. We found an exponential decay relationship between DNA fragmentation and time, and estimated a per nucleotide fragmentation rate of 1.66 × 10(-4) per year, which is six times faster than the rate estimated for ancient bones. Additionally, we found that strand breaks occur specially before purines, and that depurination-driven DNA breakage occurs constantly through time and can to a great extent explain decreasing fragment length over time. Similar to what has been found analysing ancient DNA from bones, we found a strong correlation between the deamination-driven accumulation of cytosine to thymine substitutions and time, which reinforces the importance of substitution patterns to authenticate the ancient/historical nature of DNA fragments. Accurate estimations of DNA degradation through time will allow informed decisions about laboratory and computational procedures to take advantage of the vast collection of worldwide herbarium specimens.

  13. Characterization of the Edge Crack Torsion (ECT) Test for Mode III Fracture Toughness Measurement of Laminated Composites

    NASA Technical Reports Server (NTRS)

    Ratcliffe, James G.

    2004-01-01

    The edge crack torsion (ECT) test is designed to initiate mode III delamination growth in composite laminates. An ECT specimen is a rectangular laminate, containing an edge delamination at the laminate mid-plane. Torsion load is applied to the specimens, resulting in relative transverse shear sliding of the delaminated faces. The test data reduction schemes are intended to yield initiation values of critical mode III strain energy release rate, G(sub IIIc), that are constant with delamination length. The test has undergone several design changes during its development. The objective of this paper was to determine the suitability of the current ECT test design as a mode III fracture test. To this end, ECT tests were conducted on specimens manufactured from IM7/8552 and specimens made from S2/8552 tape laminates. Several specimens, each with different delamination lengths are tested. Detailed, three-dimensional finite element analyses of the specimens were performed. The analysis results were used to calculate the distribution of mode I, mode II, and mode III strain energy release rate along the delamination front. The results indicated that mode III-dominated delamination growth would be initiated from the specimen center. However, in specimens of both material types, the measured values of G(sub IIIc) exhibited significant dependence on delamination length. Furthermore, there was a large amount of scatter in the data. Load-displacement response of the specimens exhibited significant deviation from linearity before specimen failure. X-radiographs of a sample of specimens revealed that damage was initiated in the specimens prior to failure. Further inspection of the failure surfaces is required to identify the damage and determine that mode III delamination is initiated in the specimens.

  14. The detection of fatigue cracks by nondestructive testing methods

    NASA Technical Reports Server (NTRS)

    Rummel, W. D.; Todd, P. H., Jr.; Frecska, S. A.; Rathke, R. A.

    1974-01-01

    X-radiographic penetrant, ultrasonic, eddy current, holographic, and acoustic emission techniques were optimized and applied to the evaluation of 2219-T87 aluminum alloy test specimens. One hundred eighteen specimens containing a total of 328 fatigue cracks were evaluated. The cracks ranged in length from 0.500 inch (1.27 cm) to 0.007 inch (0.018 cm) and in depth from 0.178 inch (0.451 cm) and 0.001 inch (0.003 cm). Specimen thicknesses were nominally 0.060 inch (0.152 cm) and 0.210 inch (0.532 cm) and surface finishes were nominally 32 and 125 rms and 64 and 200 rms respectively. Specimens were evaluated in the as-milled surface condition, in the chemically milled surface condition and, after proof loading, in a randomized inspection sequence. Results of the nondestructive test (NDT) evaluations were compared with actual crack size obtained by measurement of the fractured specimens. Inspection data was then analyzed to provide a statistical basis for determinating the threshold crack detection sensitivity (the largest crack size that would be missed) for each of the inspection techniques at a 95% probability and 95% confidence level.

  15. TAKASAGO-6 apparatus for cryogenic coherent X-ray diffraction imaging of biological non-crystalline particles using X-ray free electron laser at SACLA.

    PubMed

    Kobayashi, Amane; Sekiguchi, Yuki; Takayama, Yuki; Oroguchi, Tomotaka; Shirahama, Keiya; Torizuka, Yasufumi; Manoda, Masahiro; Nakasako, Masayoshi; Yamamoto, Masaki

    2016-05-01

    Coherent X-ray diffraction imaging (CXDI) is a technique for structure analyses of non-crystalline particles with dimensions ranging from micrometer to sub-micrometer. We have developed a diffraction apparatus named TAKASAGO-6 for use in single-shot CXDI experiments of frozen-hydrated non-crystalline biological particles at cryogenic temperature with X-ray free electron laser pulses provided at a repetition rate of 30 Hz from the SPring-8 Angstrom Compact free-electron LAser. Specimen particles are flash-cooled after being dispersed on thin membranes supported by specially designed disks. The apparatus is equipped with a high-speed translation stage with a cryogenic pot for raster-scanning of the disks at a speed higher than 25 μm/33 ms. In addition, we use devices assisting the easy transfer of cooled specimens from liquid-nitrogen storages to the cryogenic pot. In the current experimental procedure, more than 20 000 diffraction patterns can be collected within 1 h. Here we report the key components and performance of the diffraction apparatus. Based on the efficiency of the diffraction data collection and the structure analyses of metal particles, biological cells, and cellular organelles, we discuss the future application of this diffraction apparatus for structure analyses of biological specimens.

  16. Role of enamel deminerlization and remineralization on microtensile bond strength of resin composite

    PubMed Central

    Rizvi, Abbas; Zafar, Muhammad S.; Al-Wasifi, Yasser; Fareed, Wamiq; Khurshid, Zohaib

    2016-01-01

    Objective: This study is aimed to establish the microtensile bond strength of enamel following exposure to an aerated drink at various time intervals with/without application of remineralization agent. In addition, degree of remineralization and demineralization of tooth enamel has been assessed using polarized light microscopy. Materials and Methods: Seventy extracted human incisors split into two halves were immersed in aerated beverage (cola drink) for 5 min and stored in saliva until the time of microtensile bond testing. Prepared specimens were divided randomly into two study groups; remineralizing group (n = 70): specimens were treated for remineralization using casein phosphopeptides and amorphous calcium phosphate (CPP-ACP) remineralization agent (Recaldent™; GC Europe) and control group (n = 70): no remineralization treatment; specimens were kept in artificial saliva. All specimens were tested for microtensile bond strength at regular intervals (1 h, 1 days, 2 days, 1 week, and 2 weeks) using a universal testing machine. The results statistically analyzed (P = 0.05) using two-way ANOVA test. Results: Results showed statistically significant increase in bond strength in CPP-ACP tested group (P < 0.05) at all-time intervals. The bond strength of remineralizing group samples at 2 days (~13.64 megapascals [MPa]) is comparable to that of control group after 1 week (~12.44 MPa). Conclusions: CPP-ACP treatment of teeth exposed to an aerated drink provided significant increase in bond strength at a shorter interval compared to teeth exposed to saliva alone. PMID:27403057

  17. Crack branching in cross-ply composites

    NASA Astrophysics Data System (ADS)

    La Saponara, Valeria

    2001-10-01

    The purpose of this research work is to examine the behavior of an interface crack in a cross-ply laminate which is subject to static and fatigue loading. The failure mechanism analyzed here is crack branching (or crack kinking or intra-layer crack): the delamination located between two different plies starts growing as an interface crack and then may branch into the less tough ply. The specimens were manufactured from different types of Glass/Epoxy and Graphite/Epoxy, by hand lay-up, vacuum bagging and cure in autoclave. Each specimen had a delamination starter. Static mixed mode tests and compressive fatigue tests were performed. Experiments showed the scale of the problem, one ply thickness, and some significant features, like contact in the branched crack. The amount of scatter in the experiments required use of statistics. Exploratory Data Analysis and a factorial design of experiments based on a 8 x 8 Hadamard matrix were used. Experiments and statistics show that there is a critical branching angle above which crack growth is greatly accelerated. This angle seems: (1) not to be affected by the specimens' life; (2) not to depend on the specimen geometry and loading conditions; (3) to strongly depend on the amount of contact in the branched crack. Numerical analysis was conducted to predict crack propagation based on the actual displacement/load curves for static tests. This method allows us to predict the total crack propagation in 2D conditions, while neglecting branching. Finally, the existence of a solution based on analytic continuation is discussed.

  18. The effect on the flexural strength, flexural modulus and compressive strength of fibre reinforced acrylic with that of plain unfilled acrylic resin - an in vitro study.

    PubMed

    Thomas, Tony C; K, Aswini Kumar; Mohamed, Shamaz; Krishnan, Vinod; Mathew, Anil; V, Manju

    2015-03-01

    The aim of this in vitro study was to compare the flexural strength, the flexural modulus and compressive strength of the acrylic polymer reinforced with glass, carbon, polyethylene and Kevlar fibres with that of plain unfilled resin. A total of 50 specimens were prepared and divided into 10 specimens each under 5 groups namely group 1- control group without any fibres, group 2 - carbon fibres, group 3- glass fibres, group 4 - polyethylene, group 5- Kevlar. Universal testing machine (Tinius olsen, USA) was used for the testing of these specimens. Out of each group, 5 specimens were randomly selected and testing was done for flexural strength using a three point deflection test and three point bending test for compressive strength and the modulus was plotted using a graphical method. Statistical analysis was done using statistical software. The respective mean values for samples in regard to their flexural strength for PMMA plain, PMMA+ glass fibre, PMMA+ carbon, PMMA+ polyethylene and PMMA+ Kevlar were 90.64, 100.79, 102.58, 94.13 and 96.43 respectively. Scheffes post hoc test clearly indicated that only mean flexural strength values of PMMA + Carbon, has the highest mean value. One-way ANOVA revealed a non-significant difference among the groups in regard to their compressive strength. The study concludes that carbon fibre reinforced samples has the greatest flexural strength and greatest flexural modulus, however the compressive strength remains unchanged.

  19. Preparation And Analysis Of Specimens Of Ablative Materials

    NASA Technical Reports Server (NTRS)

    Solomon, William C.

    1994-01-01

    Procedure for chemical analysis of specimens of silicone-based ablative thermal-insulation materials SLA-561 and MA25 involves acid digestion of specimens to prepare them for analysis by inductively-coupled-plasma/atomic-emission spectroscopy (ICP/AES). In comparison with atomic-absorption spectroscopy (AAS), ICP/AES is faster and more accurate than AAS. Results of analyses stored in data base, used to trace variations in concentrations of chemical elements in materials during long-term storage, and used in timely manner in investigations of failures. Acid-digestion portion of procedure applied to other thermal-insulation materials containing room-temperature-vulcanizing silicones and enables instrumental analysis of these materials.

  20. Evaluation of Inelastic Constitutive Models for Nonlinear Structural Analysis

    NASA Technical Reports Server (NTRS)

    Kaufman, A.

    1983-01-01

    The influence of inelastic material models on computed stress-strain states, and therefore predicted lives, was studied for thermomechanically loaded structures. Nonlinear structural analyses were performed on a fatigue specimen which was subjected to thermal cycling in fluidized beds and on a mechanically load cycled benchmark notch specimen. Four incremental plasticity creep models (isotropic, kinematic, combined isotropic-kinematic, combined plus transient creep) were exercised. Of the plasticity models, kinematic hardening gave results most consistent with experimental observations. Life predictions using the computed strain histories at the critical location with a Strainrange Partitioning approach considerably overpredicted the crack initiation life of the thermal fatigue specimen.

  1. Mortality of passerines adjacent to a North Carolina corn field treated with granular carbofuran.

    USGS Publications Warehouse

    Augspurger, Tom; Smith, Milton R.; Meteyer, Carol U.; Converse, Kathryn A.

    1996-01-01

    Red-winged blackbirds (Agelaius phoeniceus) were collected during an epizootic in southeastern North Carolina (USA). Activity of brain cholinesterase (ChE) was inhibited by 14 to 48% in three of five specimens, and returned to normal levels after incubation. Gastrointestinal tracts were analyzed for 30 anti-ChE agents. Carbofuran, the only compound detected, was present in all specimens at levels from 5.44 to 72.7 μg/g wet weight. Application of granular carbofuran in an adjacent corn field, results of necropsy examinations, and chemical analyses are consistent with a diagnosis of carbofuran poisoning in these specimens.

  2. In Vivo measurement of human body composition. [during continuous bed rest

    NASA Technical Reports Server (NTRS)

    Pace, N.; Grunbaum, B. W.; Kodama, A. M.; Price, D. C.

    1975-01-01

    Physiological changes in human beings were studied during a 21 day bed rest regime. Results of blood analyses indicated clearly that major metabolic adjustments occurred during prolonged bed rest. However, urinary metabolic analyses showed variances attributed to specimen collection inaccuracies and the small number of test subjects.

  3. Biomechanical Comparison of an Open vs Arthroscopic Approach for Lateral Ankle Instability.

    PubMed

    Drakos, Mark C; Behrens, Steve B; Paller, Dave; Murphy, Conor; DiGiovanni, Christopher W

    2014-08-01

    The current clinical standard for the surgical treatment of ankle instability remains the open modified Broström procedure. Modern advents in arthroscopic technology have allowed physicians to perform certain foot and ankle procedures arthroscopically as opposed to traditional open approaches. Twenty matched lower extremity cadaver specimens were obtained. Steinman pins were inserted into the tibia and talus with 6 sensors affixed to each pin. Specimens were placed in a Telos ankle stress apparatus in an anteroposterior and then lateral position, while a 1.7 N-m load was applied. For each of these tests, movement of the sensors was measured in 3 planes using the Optotrak Computer Navigation System. Changes in position were calculated and compared with the unloaded state. The anteriortalofibular ligament and the calcaneofibular ligament were thereafter sectioned from the fibula. The aforementioned measurements in the loaded and unloaded states were repeated on the specimens. The sectioned ligaments were then repaired using 2 corkscrew anchors. Ten specimens were repaired using a standard open Broström-type repair, while the matched pairs were repaired using an arthroscopic technique. Measurements were repeated and compared using a paired t test. There was a statistically significant difference between the sectioned state and the other 3 states (P < .05). There were no statistically significant differences between the intact state and either the open or arthroscopic state (P > .05). There were no significant differences between the open and arthroscopic repairs with respect to translation and total combined motion during the talar tilt test (P > .05). Statistically significant differences were demonstrated between the 2 methods in 3 specific axes of movement during talar tilt (P = .04). Biomechanically effective ankle stabilization may be amenable to a minimally invasive approach. A minimally invasive, arthroscopic approach can be considered for treating patients with lateral ankle instability who have failed conservative treatment. © The Author(s) 2014.

  4. Histologic evaluation of post-implantation immediate C4d deposition in 13 intestinal grafts: correlation with cell-based crossmatching, cold ischemia time, and preservation injury.

    PubMed

    López-García, P; Calvo Pulido, J; Colina, F; Ballestin Carcavilla, C; Jiménez-Romero, C; Martinez González, M A; Ibarrola de Andrés, C; López-Alonso, G; Cambra Molero, F; Justo Alonso, I; Moreno-González, E

    2014-01-01

    C4d deposits are predictive of humoral rejection in kidney and heart transplantation. The aim of this study was to identify C4d deposit patterns in intestinal mucosa of the grafts on biopsy specimens obtained immediately after implantation and to detect if it could be a valuable tool to predict humoral or acute rejection. A second objective was to search for a statistically significant relationship between positive C4d deposition and other collected variables. Thirteen immediately post-transplantation mucosal graft biopsy specimens, formalin fixed, underwent immunohistochemical stain for C4d deposits. Diffuse intense staining of capillary endothelium was considered positive and absent, focal or weak stains as negative. Preservation injury grade and cold ischemia times were registered for each case. Donor-specific preformed antibodies were detected by complement dependent cytotoxicity serologic technique (crossmatching). Another 19 endoscopic follow-up biopsy specimens from days 2 to 6 were also evaluated. Statistical studies were made using the index of correlation ρ (Spearman's test). Diffuse intense C4d deposits were observed in 2 grafts, focal and weak in 5, and completely negative in 6. The mean cold ischemia time was 327 ± 101 minutes. Two cases showed diffuse positive deposits, 1 had a positive crossmatch and the cold ischemia time was 360 minutes whereas the other had not preformed antibodies and its cold ischemia time was 475 minutes. Humoral or acute rejection was not observed in follow-up mucosal biopsy specimens. There was no statistically significant relationship between the C4d deposition, cold ischemia time, crossmatching results, and preservation injury degree. In conclusion, C4d deposition was not a helpful tool for diagnosis of humoral rejection and prediction of acute rejection during the early post-transplantation period. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Surface characteristics and biocompatibility of cranioplasty titanium implants following different surface treatments.

    PubMed

    Hatamleh, Muhanad M; Wu, Xiaohong; Alnazzawi, Ahmad; Watson, Jason; Watts, David

    2018-04-01

    Surface and mechanical properties of titanium alloys are integral for their use in restoring bone defects of skull and face regions. These properties are affected by the method of constructing and surface treatment of the titanium implant. This study aimed to investigate the effects of titanium finishing protocols on the surface morphology, hardness and biocompatibility of TiAl6V4. Square shaped TiAl6V4 specimens (ASTM F68) (10×10×0.5mm) were divided into seven groups of different surface treatments (n=10). The treatments included mechanical polishing, sandblasting with AL 2 O 3 (50μm), immersion in different acids, and/or electro-chemical anodization. Weight loss %; 3D micro-roughness; Knoop micro-hardness, and osteoblast cell attachment and proliferation (after 3 days) were determined for each specimen. Data was analysed using one way ANOVA and Dunett T3 post-hoc tests, and t-test (p<0.05). Weight loss % was in the range of 1.70-5.60 as mechanical polishing produced the highest weight loss, followed by sandblasting, and combined protocol of mechanical polishing and acid treatment (p<0.05). Micro-roughness values (μm) were in the range of 2.81-16.68. It was the highest for control specimens (p<0.05), and smoothest surfaces after combined mechanical polishing and acid treatment; or after electro-chemical treatment (p<0.05). Micro-hardness values (MPa) ranged 170.90-442.15 as sandblasting with/without acid treatment caused statically significantly the highest values (p<0.05) while control and mechanically polished specimens had the lowest values (p<0.05). All treatments produced equally biocompatible surfaces (p>0.05) after 1h or 3 days. Furthermore, osteoblast cell proliferation statistically significantly increased after 3days among each surface treatment (p<0.05). Different finishing treatments have variable effect on cranioplasty titanium surface loss, micro-roughness and micro-hardness but constant improved biocompatibility effect. Electro-chemical treatment caused less material loss and produced biocompatible smoothest surface of comparable hardness; hence it can be suitable for cranioplasty titanium surface finishing. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  6. Evidence of new species for malaria vector Anopheles nuneztovari sensu lato in the Brazilian Amazon region.

    PubMed

    Scarpassa, Vera Margarete; Cunha-Machado, Antonio Saulo; Saraiva, José Ferreira

    2016-04-12

    Anopheles nuneztovari sensu lato comprises cryptic species in northern South America, and the Brazilian populations encompass distinct genetic lineages within the Brazilian Amazon region. This study investigated, based on two molecular markers, whether these lineages might actually deserve species status. Specimens were collected in five localities of the Brazilian Amazon, including Manaus, Careiro Castanho and Autazes, in the State of Amazonas; Tucuruí, in the State of Pará; and Abacate da Pedreira, in the State of Amapá, and analysed for the COI gene (Barcode region) and 12 microsatellite loci. Phylogenetic analyses were performed using the maximum likelihood (ML) approach. Intra and inter samples genetic diversity were estimated using population genetics analyses, and the genetic groups were identified by means of the ML, Bayesian and factorial correspondence analyses and the Bayesian analysis of population structure. The Barcode region dataset (N = 103) generated 27 haplotypes. The haplotype network suggested three lineages. The ML tree retrieved five monophyletic groups. Group I clustered all specimens from Manaus and Careiro Castanho, the majority of Autazes and a few from Abacate da Pedreira. Group II clustered most of the specimens from Abacate da Pedreira and a few from Autazes and Tucuruí. Group III clustered only specimens from Tucuruí (lineage III), strongly supported (97 %). Groups IV and V clustered specimens of A. nuneztovari s.s. and A. dunhami, strongly (98 %) and weakly (70 %) supported, respectively. In the second phylogenetic analysis, the sequences from GenBank, identified as A. goeldii, clustered to groups I and II, but not to group III. Genetic distances (Kimura-2 parameters) among the groups ranged from 1.60 % (between I and II) to 2.32 % (between I and III). Microsatellite data revealed very high intra-population genetic variability. Genetic distances showed the highest and significant values (P = 0.005) between Tucuruí and all the other samples, and between Abacate da Pedreira and all the other samples. Genetic distances, Bayesian (Structure and BAPS) analyses and FCA suggested three distinct biological groups, supporting the barcode region results. The two markers revealed three genetic lineages for A. nuneztovari s.l. in the Brazilian Amazon region. Lineages I and II may represent genetically distinct groups or species within A. goeldii. Lineage III may represent a new species, distinct from the A. goeldii group, and may be the most ancestral in the Brazilian Amazon. They may have differences in Plasmodium susceptibility and should therefore be investigated further.

  7. Acoustic emission analysis of fiber-reinforced composite in flexural testing.

    PubMed

    Alander, Pasi; Lassila, Lippo V J; Tezvergil, Arzu; Vallittu, Pekka K

    2004-05-01

    The aim of this study was to examine the emission of acoustic signals from six commercially available fiber-reinforced composites (FRC) used in the frameworks of fixed partial dentures in material bending. FRC test specimens were made of six commercially available fiber products of polyethylene or glass and five light-curing resins. FRC test specimens were polymerized with a hand light-curing unit or with a light-curing oven. The flexural test for determination of ultimate flexural strength of test specimens (n = 6) was based on the ISO 10477 standard after the specimens were stored in air or in water for two weeks. The acoustic emission (AE) signals were monitored during three-point loading test of the test specimens using a test with increasing loading levels until the specimens fractured. Generally, stress level required for the AE activity initiation ranged from 107 MPa (Ribbond) to 579 MPa (everStick). The ultimate flexural strength of FRC specimens were higher, ranging from 132 to 764 MPa, being highest with everStick and Vectris FRC, and lowest with Ribbond FRC. ANOVA showed a statistically significant difference between the initiation of AE activity and the ultimate flexural strength according to the brand (p < 0.001) storing conditions (p < 0.001) and polymerization procedure (p < 0.001). AE activity and ultimate flexural strength correlated significantly (p < 0.010, r = 0.887). The result of this study suggested that AE activity in FRC specimens started at a 19-32% lower stress level than occurred at final fracture.

  8. Two-body wear rate of PEEK, CAD/CAM resin composite and PMMA: Effect of specimen geometries, antagonist materials and test set-up configuration.

    PubMed

    Wimmer, Timea; Huffmann, Anne Mildred Sophie; Eichberger, Marlis; Schmidlin, Patrick R; Stawarczyk, Bogna

    2016-06-01

    To test and compare the two-body wear rate of three CAD/CAM polymer materials and the influence of specimen geometry, antagonist material and test set-up configuration. Three CAD/CAM polymeric materials were assessed: a thermoplastic polyetheretherketone (PEEK), an experimental nanohybrid composite (COMP) and a PMMA-based material (PMMA). Crown-shaped and flat specimens were prepared from each material. The specimens underwent thermo-mechanical loading (50N, 5/55°C; 600,000 chewing cycles) opposed to human enamel and stainless steel antagonists. Half of the specimens of each group were loaded with a sliding movement of 0.7mm, the remaining half without. Thereby, 24 different test set-ups were investigated (n=12). Wear of the materials and antagonists was evaluated with a match-3D procedure. The topography of all surfaces was examined with scanning electron microscopy (SEM). Data were statistically evaluated with four-/one-way ANOVA followed by Scheffé post hoc test and unpaired t-test (p<0.05). All PEEK specimens showed significantly less material loss than COMP and PMMA specimens when loaded laterally. Within the axial loaded groups this was only true for the flat specimens tested with enamel antagonists. Crown specimens of these groups exhibited lower loss values than flat ones. Lateral force application led mostly to significantly higher material loss than the axial load application. On the antagonist side, no impact of CAD/CAM polymer material, antagonist material, force application and specimen geometry was found. Wear of PEEK was lower than that of the resin-based materials when lateral forces were applied, but showed comparable antagonist wear rates at the same time. Copyright © 2016 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  9. Laser and Electrochemical Studies of Metallizations Electronic Devices

    DTIC Science & Technology

    1990-10-01

    AES Surface Analyses Profile at Laser Non-Irradiated Zone .... ............ .. 47 Fig 3.15 AES Surface Analyses Profile at laser Gold Depsit Zone...After Various Times of Ion Sputtering .... ............. ... 48 Fig 3.16 ESCA Surface Analyses Profile of Laser Gold Deposit Zone After Sputtering...57 Table 3.4 Resistance Measurement of Two Point Probes Laser Gold Line Deposits on Superconductive Specimen Material ..... . 58 Fig 3.19

  10. Arctic biodiversity: Increasing richness accompanies shrinking refugia for a cold-associated tundra fauna

    USGS Publications Warehouse

    Hope, Andrew G.; Waltari, Eric; Malaney, Jason L.; Payer, David C.; Cook, J.A.; Talbot, Sandra L.

    2015-01-01

    As ancestral biodiversity responded dynamically to late-Quaternary climate changes, so are extant organisms responding to the warming trajectory of the Anthropocene. Ecological predictive modeling, statistical hypothesis tests, and genetic signatures of demographic change can provide a powerful integrated toolset for investigating these biodiversity responses to climate change, and relative resiliency across different communities. Within the biotic province of Beringia, we analyzed specimen localities and DNA sequences from 28 mammal species associated with boreal forest and Arctic tundra biomes to assess both historical distributional and evolutionary responses and then forecasted future changes based on statistical assessments of past and present trajectories, and quantified distributional and demographic changes in relation to major management regions within the study area. We addressed three sets of hypotheses associated with aspects of methodological, biological, and socio-political importance by asking (1) what is the consistency among implications of predicted changes based on the results of both ecological and evolutionary analyses; (2) what are the ecological and evolutionary implications of climate change considering either total regional diversity or distinct communities associated with major biomes; and (3) are there differences in management implications across regions? Our results indicate increasing Arctic richness through time that highlights a potential state shift across the Arctic landscape. However, within distinct ecological communities, we found a predicted decline in the range and effective population size of tundra species into several discrete refugial areas. Consistency in results based on a combination of both ecological and evolutionary approaches demonstrates increased statistical confidence by applying cross-discipline comparative analyses to conservation of biodiversity, particularly considering variable management regimes that seek to balance sustainable ecosystems with other anthropogenic values. Refugial areas for cold-adapted taxa appear to be persistent across both warm and cold climate phases and although fragmented, constitute vital regions for persistence of Arctic mammals.

  11. Ultrasonic wave velocity measurement in small polymeric and cortical bone specimens

    NASA Technical Reports Server (NTRS)

    Kohles, S. S.; Bowers, J. R.; Vailas, A. C.; Vanderby, R. Jr

    1997-01-01

    A system was refined for the determination of the bulk ultrasonic wave propagation velocity in small cortical bone specimens. Longitudinal and shear wave propagations were measured using ceramic, piezoelectric 20 and 5 MHz transducers, respectively. Results of the pulse transmission technique were refined via the measurement of the system delay time. The precision and accuracy of the system were quantified using small specimens of polyoxymethylene, polystyrene-butadiene, and high-density polyethylene. These polymeric materials had known acoustic properties, similarity of propagation velocities to cortical bone, and minimal sample inhomogeneity. Dependence of longitudinal and transverse specimen dimensions upon propagation times was quantified. To confirm the consistency of longitudinal wave propagation in small cortical bone specimens (< 1.0 mm), cut-down specimens were prepared from a normal rat femur. Finally, cortical samples were prepared from each of ten normal rat femora, and Young's moduli (Eii), shear moduli (Gij), and Poisson ratios (Vij) were measured. For all specimens (bone, polyoxymethylene, polystyrene-butadiene, and high-density polyethylene), strong linear correlations (R2 > 0.997) were maintained between propagation time and distance throughout the size ranges down to less than 0.4 mm. Results for polyoxymethylene, polystyrene-butadiene, and high-density polyethylene were accurate to within 5 percent of reported literature values. Measurement repeatability (precision) improved with an increase in the wave transmission distance (propagating dimension). No statistically significant effect due to the transverse dimension was detected.

  12. Precision of Multiple Reaction Monitoring Mass Spectrometry Analysis of Formalin-Fixed, Paraffin-Embedded Tissue

    PubMed Central

    2012-01-01

    We compared the reproducibility of multiple reaction monitoring (MRM) mass spectrometry-based peptide quantitation in tryptic digests from formalin-fixed, paraffin-embedded (FFPE) and frozen clear cell renal cell carcinoma tissues. The analyses targeted a candidate set of 114 peptides previously identified in shotgun proteomic analyses, of which 104 were detectable in FFPE and frozen tissue. Although signal intensities for MRM of peptides from FFPE tissue were on average 66% of those in frozen tissue, median coefficients of variation (CV) for measurements in FFPE and frozen tissues were nearly identical (18–20%). Measurements of lysine C-terminal peptides and arginine C-terminal peptides from FFPE tissue were similarly reproducible (19.5% and 18.3% median CV, respectively). We further evaluated the precision of MRM-based quantitation by analysis of peptides from the Her2 receptor in FFPE and frozen tissues from a Her2 overexpressing mouse xenograft model of breast cancer and in human FFPE breast cancer specimens. We obtained equivalent MRM measurements of HER2 receptor levels in FFPE and frozen mouse xenografts derived from HER2-overexpressing BT474 cells and HER2-negative Sum159 cells. MRM analyses of 5 HER2-positive and 5 HER-negative human FFPE breast tumors confirmed the results of immunohistochemical analyses, thus demonstrating the feasibility of HER2 protein quantification in FFPE tissue specimens. The data demonstrate that MRM analyses can be performed with equal precision on FFPE and frozen tissues and that lysine-containing peptides can be selected for quantitative comparisons, despite the greater impact of formalin fixation on lysine residues. The data further illustrate the feasibility of applying MRM to quantify clinically important tissue biomarkers in FFPE specimens. PMID:22530795

  13. Characterisation of swabbing for virological analysis in the Spanish Influenza Sentinel Surveillance System during four influenza seasons in the period 2002-2006.

    PubMed

    Larrauri, A; de Mateo, S

    2007-05-01

    This study sought to characterise the swabbing pattern in the Spanish Influenza Sentinel Surveillance System (SISSS) and ascertain to what extent the system meets the guidelines currently being drafted by The European Influenza Surveillance Scheme (EISS). Data on seasons 2002/2003 to 2005/2006 were drawn from SISSS. The study analysed collection and dispatch of swab specimens for virological analysis by reference to variables relating to patient sex, age group, vaccination status, specimen collection period, period of influenza activity, time of swabbing and epidemiological season. SISSS adapts to EISS recommendations with respect to the specimen collection period and period of influenza activity, but there is a tendency to collect fewer specimens than recommended as the age of patients increases, and in the case of elderly patients (65 years and older), frequency of collection is clearly insufficient. Furthermore, sentinel physicians collect a higher percentage of specimens in cases where patients have received the influenza vaccine.

  14. EXAMINATION OF Zr AND Ti RECOMBINER LOOP SPECIMENS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rittenhouse, P.L.

    1958-12-19

    Cold-worked specimens of iodide zirconium, Zircaloy-2, iodide titanium, and A-55 titanium were tested in a high-pressure recombiner loop in an attempt to duplicate anomalous results obtained in a prior recombiner loop. Hydrogen analyses and metallographic examinations were made on all specimens. The titanium materials and Zircaloy-2 picked up major amounts of hydrogen in the cell section. None of the materials tested showed appreciable hydrogen absorption in the recombiner section. Complete recrystallization occurred in all cell specimens while only Zircaloy-2, of the recombiner specimens, showed any degree of recrystallization. No explanation for this behavior can be given. A survnnary of themore » data obtained in previous recombiner loops is compared with the results of this loop. Conclusions were based on the results of three recombiner loops. Primarlly because of the hydrogen absorption data obtained in all three recombiner loops it is recommended that the zirconium and titunium materials tested not be used in environments similar to those encountered in high pressure recombiner loops. (auth)« less

  15. Detection of Pneumocystis jirovecii dihydropteroate synthase polymorphisms in patients with Pneumocystis pneumonia.

    PubMed

    Costa, M C; Gaspar, J; Mansinho, K; Esteves, F; Antunes, F; Matos, O

    2005-01-01

    In the present study, in order to improve the detection of Pneumocystis jirovecii dihydropteroate synthase (DHPS) mutations in pulmonary specimens of HIV-infected patients with P. jirovecii pneumonia, we evaluated a microfiltration procedure for the removal of human cell contamination and a nested-PCR method, for amplification in specimens with low parasite load. In the studied population, PCR amplification of the DHPS gene was more successful in unfiltered than in filtered specimens, with both touchdown-PCR and nested-PCR procedures (p<0.05 and p<0.001, respectively), but the amount of host DNA in the samples analysed seems to be inversely related with the successful PCR parasite detection. Amplification of P. jirovecii DHPS gene with nested-PCR was achieved in 77.5% of the specimens studied, demonstrating that this is a useful method for the identification of mutations in pulmonary specimens, including samples with low parasite loads, and will facilitate the evaluation of the relationship between the P. jirovecii DHPS polymorphisms and clinical resistance to sulfa drugs.

  16. Sympatric distribution of three human Taenia tapeworms collected between 1935 and 2005 in Korea.

    PubMed

    Jeon, Hyeong-Kyu; Kim, Kyu-Heon; Chai, Jong-Yil; Yang, Hyun-Jong; Rim, Han-Jong; Eom, Keeseon S

    2008-12-01

    Taeniasis has been known as one of the prevalent parasitic infections in Korea. Until recently, Taenia saginata had long been considered a dominant, and widely distributed species but epidemiological profiles of human Taenia species in Korea still remain unclear. In order to better understand distribution patterns of human Taenia tapeworms in Korea, partial nucleotide sequences of mitochondrial cox1 and ITS2 (internal transcribed spacer 2) were determined, along with morphological examinations, on 68 Taenia specimens obtained from university museum collections deposited since 1935. Genomic DNA was extracted from formalin-preserved specimens. Phylogenetic relationships among the genotypes (cox1 haplotype) detected in this study were inferred using the neighbor-joining method as a tree building method. Morphological and genetic analyses identified 3 specimens as T. solium, 51 specimens as T. asiatica, and 14 specimens as T. saginata. Our results indicate that all 3 Taenia tapeworms are sympatrically distributed in Korea with T. asiatica dominating over T. saginata and T. solium.

  17. Sympatric Distribution of Three Human Taenia Tapeworms Collected between 1935 and 2005 in Korea

    PubMed Central

    Jeon, Hyeong-Kyu; Kim, Kyu-Heon; Chai, Jong-Yil; Yang, Hyun-Jong; Rim, Han-Jong

    2008-01-01

    Taeniasis has been known as one of the prevalent parasitic infections in Korea. Until recently, Taenia saginata had long been considered a dominant, and widely distributed species but epidemiological profiles of human Taenia species in Korea still remain unclear. In order to better understand distribution patterns of human Taenia tapeworms in Korea, partial nucleotide sequences of mitochondrial cox1 and ITS2 (internal transcribed spacer 2) were determined, along with morphological examinations, on 68 Taenia specimens obtained from university museum collections deposited since 1935. Genomic DNA was extracted from formalin-preserved specimens. Phylogenetic relationships among the genotypes (cox1 haplotype) detected in this study were inferred using the neighbor-joining method as a tree building method. Morphological and genetic analyses identified 3 specimens as T. solium, 51 specimens as T. asiatica, and 14 specimens as T. saginata. Our results indicate that all 3 Taenia tapeworms are sympatrically distributed in Korea with T. asiatica dominating over T. saginata and T. solium. PMID:19127329

  18. On fractography of shallow and deep HY-100 cracked bend specimens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuan, D.W.; Zarzour, J.F.; Kleinosky, M.J.

    1994-12-01

    The influence of shallow cracks on the fracture behavior of structural components has been studied extensively in recent years. Finite element analyses have indicated dramatic differences in the crack-tip stress states between shallow and deep cracked bend specimens. In this study, an experimental program was carried out to investigate the fracture behavior of HY-100 steel containing various initial flaw depths. Four a/w ratios ranging from 0.05 to 0.5 were chosen for the notched three-point bend tests. Test results showed that higher fracture toughness values are associated with specimens having shorter surface cracks. Also, fractographic studies indicated that two sets ofmore » dimples are present for a/w = 0.5 specimen, one set of equiaxed dimple for a/w = 0.05 specimen near the crack initiation zone. As the crack grows, increase in the volume fraction of the small dimple were observed. Finally, it showed that the characteristic features of the fracture surfaces can be correlated with the previous numerical predictions.« less

  19. High Load Ratio Fatigue Strength and Mean Stress Evolution of Quenched and Tempered 42CrMo4 Steel

    NASA Astrophysics Data System (ADS)

    Bertini, Leonardo; Le Bone, Luca; Santus, Ciro; Chiesi, Francesco; Tognarelli, Leonardo

    2017-08-01

    The fatigue strength at a high number of cycles with initial elastic-plastic behavior was experimentally investigated on quenched and tempered 42CrMo4 steel. Fatigue tests on unnotched specimens were performed both under load and strain controls, by imposing various levels of amplitude and with several high load ratios. Different ratcheting and relaxation trends, with significant effects on fatigue, are observed and discussed, and then reported in the Haigh diagram, highlighting a clear correlation with the Smith-Watson-Topper model. High load ratio tests were also conducted on notched specimens with C (blunt) and V (sharp) geometries. A Chaboche model with three parameter couples was proposed by fitting plain specimen cyclic and relaxation tests, and then finite element analyses were performed to simulate the notched specimen test results. A significant stress relaxation at the notch root became clearly evident by reporting the numerical results in the Haigh diagram, thus explaining the low mean stress sensitivity of the notched specimens.

  20. Virtual anthropology.

    PubMed

    Weber, Gerhard W

    2015-02-01

    Comparative morphology, dealing with the diversity of form and shape, and functional morphology, the study of the relationship between the structure and the function of an organism's parts, are both important subdisciplines in biological research. Virtual anthropology (VA) contributes to comparative morphology by taking advantage of technological innovations, and it also offers new opportunities for functional analyses. It exploits digital technologies and pools experts from different domains such as anthropology, primatology, medicine, paleontology, mathematics, statistics, computer science, and engineering. VA as a technical term was coined in the late 1990s from the perspective of anthropologists with the intent of being mostly applied to biological questions concerning recent and fossil hominoids. More generally, however, there are advanced methods to study shape and size or to manipulate data digitally suitable for application to all kinds of primates, mammals, other vertebrates, and invertebrates or to issues regarding plants, tools, or other objects. In this sense, we could also call the field "virtual morphology." The approach yields permanently available virtual copies of specimens and data that comprehensively quantify geometry, including previously neglected anatomical regions. It applies advanced statistical methods, supports the reconstruction of specimens based on reproducible manipulations, and promotes the acquisition of larger samples by data sharing via electronic archives. Finally, it can help identify new, hidden traits, which is particularly important in paleoanthropology, where the scarcity of material demands extracting information from fragmentary remains. This contribution presents a current view of the six main work steps of VA: digitize, expose, compare, reconstruct, materialize, and share. The VA machinery has also been successfully used in biomechanical studies which simulate the stress and strains appearing in structures. Although methodological issues remain to be solved before results from the two domains can be fully integrated, the various overlaps and cross-fertilizations suggest the widespread appearance of a "virtual functional morphology" in the near future. © 2014 American Association of Physical Anthropologists.

  1. Adaptation and micro-structure of Co-Cr alloy maxillary complete denture base plates fabricated by selective laser melting technique.

    PubMed

    Ye, Ye; Jiao, Ting; Zhu, Jiarui; Sun, Jian

    2018-01-24

    The purpose of the study was to evaluate the adaptation and micro-structure of Co-Cr alloy maxillary complete denture base plates fabricated by the selective laser melting (SLM) technique. Twenty pairs of edentulous casts were randomly and evenly divided into two groups, and manufacturing of the Co-Cr alloy maxillary complete denture base was conducted either by the SLM technique or by the conventional method. The base-cast sets were transversally sectioned into three sections at the distal canines, mesial of the first molars and the posterior palatal zone. The gap between the metal base and cast was measured in these three sections with a stereoscopic microscope, and the data were analysed using t tests. A total of five specimens of 5 mm diameter were fabricated with the Co-Cr alloy by SLM and the traditional casting technology. A scanning electron microscope (SEM) was used to evaluate the differences in microstructure between these specimens. There was no statistical difference between the three sections in all four groups (P > 0.05). At the region of the canines, the clearance value for the SLM Co-Cr alloy group was larger than that of the conventional method group (P < 0.05). At the mesial of the first molar region and the posterior palatal zone, there was no statistical difference between the gaps observed in the two groups (P > 0.05). The SLM Co-Cr alloy has a denser microstructure behaviour and less casting defect than the cast Co-Cr alloy. The SLM technique showed initial feasibility for the manufacture of dental bases of complete dentures, but large sample studies are needed to prove its reliability in clinical applications. The mechanical properties and microstructure of the denture frameworks prepared by selective laser melting indicate that these dentures are appropriate for clinical use.

  2. Wear characteristics of current aesthetic dental restorative CAD/CAM materials: two-body wear, gloss retention, roughness and Martens hardness.

    PubMed

    Mörmann, Werner H; Stawarczyk, Bogna; Ender, Andreas; Sener, Beatrice; Attin, Thomas; Mehl, Albert

    2013-04-01

    This study determined the two-body wear and toothbrushing wear parameters, including gloss and roughness measurements and additionally Martens hardness, of nine aesthetic CAD/CAM materials, one direct resin-based nanocomposite plus that of human enamel as a control group. Two-body wear was investigated in a computer-controlled chewing simulator (1.2 million loadings, 49N at 1.7Hz; 3000 thermocycles 5/50°C). Each of the 11 groups consisted of 12 specimens and 12 enamel antagonists. Quantitative analysis of wear was carried out with a 3D-surface analyser. Gloss and roughness measurements were evaluated using a glossmeter and an inductive surface profilometer before and after abrasive toothbrushing of machine-polished specimens. Additionally Martens hardness was measured. Statistically significant differences were calculated with one-way ANOVA (analysis of variance). Statistically significant differences were found for two-body wear, gloss, surface roughness and hardness. Zirconium dioxide ceramics showed no material wear and low wear of the enamel antagonist. Two-body wear of CAD/CAM-silicate and -lithium disilicate ceramics, -hybrid ceramics and -nanocomposite as well as direct nanocomposite did not differ significantly from that of human enamel. Temporary polymers showed significantly higher material wear than permanent materials. Abrasive toothbrushing significantly reduced gloss and increased roughness of all materials except zirconium dioxide ceramics. Gloss retention was highest with zirconium dioxide ceramics, silicate ceramics, hybrid ceramics and nanocomposites. Temporary polymers showed least gloss retention. Martens hardness differed significantly among ceramics, between ceramics and composites, and between resin composites and acrylic block materials as well. All permanent aesthetic CAD/CAM block materials tested behave similarly or better with respect to two-body wear and toothbrushing wear than human enamel, which is not true for temporary polymer CAD/CAM block materials. Ceramics show the best gloss retention compared to hybrid ceramics, composites and acrylic polymers. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. [The helminth fauna structure of wild rodents from differential sites of Wrocław area].

    PubMed

    Hildebrand, Joanna

    2008-01-01

    The parasite fauna of rodents was studied in the Wrocław area from 2001 to 2005. The first location was irrigation fields (Wrocław Osobowice), the second--a water distribution area (Wrocław Mokry Dwór). Helminthological material was collected during parasitological examination of 447 specimens of wildlife rodents (belonging to 7 species of Muridae). The helminth population and the helminth communities' structure were analyzed, their qualitative and quantitative characteristics were described by parasitological and ecological parameters. Significance of differences was tested by the chi-square test. Prevalence data was analysed by maximum likelihood techniques based on log-linear analysis of contingency tables using Statistica v.7.1. for ecological analysis Estimates was used. A total of 7787 helminth specimens belonging to 32 taxa were found: 16 nematodes, 12 cestodes and 4 digeneans. Any species of Acanthocephala was reported. The prevalence of helminths was 73.8%, mean intensity of infection--23.6 and mean abundance--17.4. In results of this research the new species of fluke Brachylecithum galreoli was described. Four species of nematodes were reported as new for Polish helminth fauna. Seventeen helminth species were found for the first time in Lower Silesia. The study showed qualitative and quantitative differences in the compound community and component community structure of helminths depending on site-specific conditions. A comparison of the helminth communities of Apodemus flavicollis revealed the biggest differences. This research did not reveal a statistically significant influence of host sex on total prevalence of infection. The differences in seasonal activity of small rodents had influence on prevalence of helminths. The parasites occurred proportional more frequently in summer and autumn in rodent populations. Co-occurrence of helminth species in individual host was observed (56.1% of rodents infected). The most frequent co-occurrence was of two species Heligmosomoides polygyrus and Trichuris muris parasitizing the yellow-necked mouse. These relationships were positive and statistic significant.

  4. Electron microprobe analysis program for biological specimens: BIOMAP

    NASA Technical Reports Server (NTRS)

    Edwards, B. F.

    1972-01-01

    BIOMAP is a Univac 1108 compatible program which facilitates the electron probe microanalysis of biological specimens. Input data are X-ray intensity data from biological samples, the X-ray intensity and composition data from a standard sample and the electron probe operating parameters. Outputs are estimates of the weight percentages of the analyzed elements, the distribution of these estimates for sets of red blood cells and the probabilities for correlation between elemental concentrations. An optional feature statistically estimates the X-ray intensity and residual background of a principal standard relative to a series of standards.

  5. Bonding characteristics of self-etching adhesives to intact versus prepared enamel.

    PubMed

    Perdigão, Jorge; Geraldeli, Saulo

    2003-01-01

    This study tested the null hypothesis that the preparation of the enamel surface would not affect the enamel microtensile bond strengths of self-etching adhesive materials. Ten bovine incisors were trimmed with a diamond saw to obtain a squared enamel surface with an area of 8 x 8 mm. The specimens were randomly assigned to five adhesives: (1) ABF (Kuraray), an experimental two-bottle self-etching adhesive; (2) Clearfil SE Bond (Kuraray), a two-bottle self-etching adhesive; (3) One-Up Bond F (Tokuyama), an all-in-one adhesive; (4) Prompt L-Pop (3M ESPE), an all-in-one adhesive; and (5) Single Bond (3M ESPE), a two-bottle total-etch adhesive used as positive control. For each specimen, one half was roughened with a diamond bur for 5 seconds under water spray, whereas the other half was left unprepared. The adhesives were applied as per manufacturers' directions. A universal hybrid composite resin (Filtek Z250, 3M ESPE) was inserted in three layers of 1.5 mm each and light-cured. Specimens were sectioned in X and Y directions to obtain bonded sticks with a cross-sectional area of 0.8 +/- 0.2 mm2. Sticks were tested in tension in an Instron at a cross-speed of 1 mm per minute. Statistical analysis was carried out with two-way analysis of variance and Duncan's test at p < .05. Ten extra specimens were processed for observation under a field-emission scanning electron microscope. Single Bond, the total-etch adhesive, resulted in statistically higher microtensile bond strength than any of the other adhesives regardless of the enamel preparation (unprepared = 31.5 MPa; prepared = 34.9 MPa, not statistically different at p < .05). All the self-etching adhesives resulted in higher microtensile bond strength when enamel was roughened than when enamel was left unprepared. However, for ABF and for Clearfil SE Bond this difference was not statistically significant at p > .05. When applied to ground enamel, mean bond strengths of Prompt L-Pop were not statistically different from those of Clearfil SE Bond and ABF. One-Up Bond F did not bond to unprepared enamel. Commercial self-etching adhesives performed better on prepared enamel than on unprepared enamel. The field-emission scanning electron microscope revealed a deep interprismatic etching pattern for the total-etch adhesive, whereas the self-etching systems resulted in an etching pattern ranging from absent to moderate.

  6. Laser-scanned fluorescence of nonlased/normal, lased/normal, nonlased/carious, and lased/carious enamel

    NASA Astrophysics Data System (ADS)

    Zakariasen, Kenneth L.; Barron, Joseph R.; Paton, Barry E.

    1992-06-01

    Research has shown that low levels of CO2 laser irradiation raise enamel resistance to sub-surface demineralization. Additionally, laser scanned fluorescence analysis of enamel, as well a laser and white light reflection studies, have potential for both clinical diagnosis and comparative research investigations of the caries process. This study was designed to compare laser fluorescence and laser/white light reflection of (1) non-lased/normal with lased/normal enamel and (2) non-lased/normal with non-lased/carious and lased/carious enamel. Specimens were buccal surfaces of extracted third molars, coated with acid resistant varnish except for either two or three 2.25 mm2 windows (two window specimens: non-lased/normal, lased/normal--three window specimens: non-lased/normal, non-lased carious, lased/carious). Teeth exhibiting carious windows were immersed in a demineralizing solution for twelve days. Non-carious windows were covered with wax during immersion. Following immersion, the wax was removed, and fluorescence and laser/white light reflection analyses were performed on all windows utilizing a custom scanning laser fluorescence spectrometer which focuses light from a 25 mWatt He-Cd laser at 442 nm through an objective lens onto a cross-section >= 3 (mu) in diameter. For laser/white light reflection analyses, reflected light intensities were measured. A HeNe laser was used for laser light reflection studies. Following analyses, the teeth are sectioned bucco-lingually into 80 micrometers sections, examined under polarized light microscopy, and the lesions photographed. This permits comparison between fluorescence/reflected light values and the visualized decalcification areas for each section, and thus comparisons between various enamel treatments and normal enamel. The enamel specimens are currently being analyzed.

  7. Clinical map document based on XML (cMDX): document architecture with mapping feature for reporting and analysing prostate cancer in radical prostatectomy specimens.

    PubMed

    Eminaga, Okyaz; Hinkelammert, Reemt; Semjonow, Axel; Neumann, Joerg; Abbas, Mahmoud; Koepke, Thomas; Bettendorf, Olaf; Eltze, Elke; Dugas, Martin

    2010-11-15

    The pathology report of radical prostatectomy specimens plays an important role in clinical decisions and the prognostic evaluation in Prostate Cancer (PCa). The anatomical schema is a helpful tool to document PCa extension for clinical and research purposes. To achieve electronic documentation and analysis, an appropriate documentation model for anatomical schemas is needed. For this purpose we developed cMDX. The document architecture of cMDX was designed according to Open Packaging Conventions by separating the whole data into template data and patient data. Analogue custom XML elements were considered to harmonize the graphical representation (e.g. tumour extension) with the textual data (e.g. histological patterns). The graphical documentation was based on the four-layer visualization model that forms the interaction between different custom XML elements. Sensible personal data were encrypted with a 256-bit cryptographic algorithm to avoid misuse. In order to assess the clinical value, we retrospectively analysed the tumour extension in 255 patients after radical prostatectomy. The pathology report with cMDX can represent pathological findings of the prostate in schematic styles. Such reports can be integrated into the hospital information system. "cMDX" documents can be converted into different data formats like text, graphics and PDF. Supplementary tools like cMDX Editor and an analyser tool were implemented. The graphical analysis of 255 prostatectomy specimens showed that PCa were mostly localized in the peripheral zone (Mean: 73% ± 25). 54% of PCa showed a multifocal growth pattern. cMDX can be used for routine histopathological reporting of radical prostatectomy specimens and provide data for scientific analysis.

  8. Clinical map document based on XML (cMDX): document architecture with mapping feature for reporting and analysing prostate cancer in radical prostatectomy specimens

    PubMed Central

    2010-01-01

    Background The pathology report of radical prostatectomy specimens plays an important role in clinical decisions and the prognostic evaluation in Prostate Cancer (PCa). The anatomical schema is a helpful tool to document PCa extension for clinical and research purposes. To achieve electronic documentation and analysis, an appropriate documentation model for anatomical schemas is needed. For this purpose we developed cMDX. Methods The document architecture of cMDX was designed according to Open Packaging Conventions by separating the whole data into template data and patient data. Analogue custom XML elements were considered to harmonize the graphical representation (e.g. tumour extension) with the textual data (e.g. histological patterns). The graphical documentation was based on the four-layer visualization model that forms the interaction between different custom XML elements. Sensible personal data were encrypted with a 256-bit cryptographic algorithm to avoid misuse. In order to assess the clinical value, we retrospectively analysed the tumour extension in 255 patients after radical prostatectomy. Results The pathology report with cMDX can represent pathological findings of the prostate in schematic styles. Such reports can be integrated into the hospital information system. "cMDX" documents can be converted into different data formats like text, graphics and PDF. Supplementary tools like cMDX Editor and an analyser tool were implemented. The graphical analysis of 255 prostatectomy specimens showed that PCa were mostly localized in the peripheral zone (Mean: 73% ± 25). 54% of PCa showed a multifocal growth pattern. Conclusions cMDX can be used for routine histopathological reporting of radical prostatectomy specimens and provide data for scientific analysis. PMID:21078179

  9. Specimen-level phylogenetics in paleontology using the Fossilized Birth-Death model with sampled ancestors.

    PubMed

    Cau, Andrea

    2017-01-01

    Bayesian phylogenetic methods integrating simultaneously morphological and stratigraphic information have been applied increasingly among paleontologists. Most of these studies have used Bayesian methods as an alternative to the widely-used parsimony analysis, to infer macroevolutionary patterns and relationships among species-level or higher taxa. Among recently introduced Bayesian methodologies, the Fossilized Birth-Death (FBD) model allows incorporation of hypotheses on ancestor-descendant relationships in phylogenetic analyses including fossil taxa. Here, the FBD model is used to infer the relationships among an ingroup formed exclusively by fossil individuals, i.e., dipnoan tooth plates from four localities in the Ain el Guettar Formation of Tunisia. Previous analyses of this sample compared the results of phylogenetic analysis using parsimony with stratigraphic methods, inferred a high diversity (five or more genera) in the Ain el Guettar Formation, and interpreted it as an artifact inflated by depositional factors. In the analysis performed here, the uncertainty on the chronostratigraphic relationships among the specimens was included among the prior settings. The results of the analysis confirm the referral of most of the specimens to the taxa Asiatoceratodus , Equinoxiodus, Lavocatodus and Neoceratodus , but reject those to Ceratodus and Ferganoceratodus . The resulting phylogeny constrained the evolution of the Tunisian sample exclusively in the Early Cretaceous, contrasting with the previous scenario inferred by the stratigraphically-calibrated topology resulting from parsimony analysis. The phylogenetic framework also suggests that (1) the sampled localities are laterally equivalent, (2) but three localities are restricted to the youngest part of the section; both results are in agreement with previous stratigraphic analyses of these localities. The FBD model of specimen-level units provides a novel tool for phylogenetic inference among fossils but also for independent tests of stratigraphic scenarios.

  10. A comparison of microscopic ink characteristics of 35 commercially available surgical margin inks.

    PubMed

    Milovancev, Milan; Löhr, Christiane V; Bildfell, Robert J; Gelberg, Howard B; Heidel, Jerry R; Valentine, Beth A

    2013-11-01

    To compare microscopic characteristics of commercially available surgical margin inks used for surgical pathology specimens. Prospective in vitro study. Thirty-five different surgical margin inks (black, blue, green, orange, red, violet, and yellow from 5 different manufacturers). Inks were applied to uniform, single-source, canine cadaveric full-thickness ventral abdominal tissue blocks. Tissue blocks and ink manufacturers were randomly paired and each color was applied to a length of the cut tissue margin. After drying, tissues were fixed in formalin, and 3 radial slices were obtained from each color section and processed for routine histologic evaluation, yielding 105 randomly numbered slides with each manufacturer's color represented in triplicate. Slides were evaluated by 5 blinded, board-certified veterinary anatomic pathologists using a standardized scoring scheme. Statistical analyses were performed to evaluate for ink manufacturer effects on scores, correlation among different subjective variables, and pathologist agreement. Black and blue had the most consistently high scores whereas red and violet had the most consistently low overall scores, across all manufacturers. All colors tested, except yellow, had statistically significant differences in overall scores among individual manufacturers. Overall score was significantly correlated to all other subjective microscopic scores evaluated. The average Spearman correlation coefficient among the 10 pairwise pathologists overall ink scores was 0.60. There are statistically significant differences in microscopic ink characteristics among manufacturers, with a notable degree of inter-pathologist agreement. © Copyright 2013 by The American College of Veterinary Surgeons.

  11. Sealing ability of root-end filling materials.

    PubMed

    Amezcua, Octávio; Gonzalez, Álvaro Cruz; Borges, Álvaro Henrique; Bandeca, Matheus Coelho; Estrela, Cyntia Rodrigues de Araújo; Estrela, Carlos

    2015-03-01

    The aim of this research was to compare the apical sealing ability of different root-end filling materials (SuperEBA(®), ProRoot MTA(®), thermoplasticized gutta-percha + AH-Plus(®), thermoplasticized RealSeal(®)), by means of microbial indicators. Thus, 50 human single-rooted teeth were employed, which were shaped until size 5 0, retro - prepared with ultrasonic tips and assigned to 4 groups, retro-filled with each material or controls. A platform was employed, which was split in two halves: upper chamber-where the microbial suspension containing the biological indicators was introduced (E. faecalis + S. aureus + P. aeruginosa + B. subtilis + C. albicans); and a lower chamber containing the culture medium brain, heart influsion, where 3 mm of the apical region of teeth were kept immersed. Lectures were made daily for 60 days, using the turbidity of the culture medium as indicative of microbial contamination. Statistical analyses were carried out at 5% level of significance. The results showed microbial leakage at least in some specimens in all of the groups. RealSeal(®) has more microbial leakage, statistically significant, compared to ProRoot(®) MTA and SuperEBA(®). No significant differences were observed when compared ProRoot(®) MTA and SuperEBA(®). The gutta-percha + AH Plus results showed no statistically significant differences when compared with the other groups. All the tested materials showed microbial leakage. Root-end fillings with Super-EBA or MTA had the lowest bacterial filtration and RealSeal shows highest bacterial filtration.

  12. Relating appendicular skeletal variation of sigmodontine rodents to locomotion modes in a phylogenetic context.

    PubMed

    Carvalho Coutinho, Ludmilla; Alves de Oliveira, João

    2017-10-01

    Sigmodontinae rodents constitute the second-largest subfamily among mammals. Alongside the taxonomic diversity, they are also ecologically diverse, exhibiting a wide array of locomotion modes, with semifossorial, terrestrial, semiaquatic, scansorial, arboreal, and saltatorial forms. To understand the ecomorphologic aspects that allow these rodents to display such locomotion diversity, we analyzed 35 qualitative characters of the appendicular skeleton (humerus, ulna, radius, scapula, femur, tibia, ilium, ischium and pubis) in 795 specimens belonging to 64 species, 34 genera and 10 tribes, representing all locomotion modes assigned to this subfamily. We performed a statistical analysis based upon the coefficient of trait differentiation to test the congruence of character states and the different locomotion modes. We also mapped characters states in a molecular phylogeny in order to reconstruct ancestral states and to evaluate how appendicular characters evolved within main lineages of Sigmodontinae radiation under a phylogenetic framework. The statistical analyses revealed six characters related to specific locomotion modes, except terrestrial. The mapping and parsimony ancestral states reconstruction identified two characters with phylogenetical signal and eight characters that are exclusively or more frequently recorded in certain modes of locomotion, four of them also detected by the statistical analysis. Notwithstanding the documented morphological variation, few changes characterize the transition to each of the locomotion modes, at least regarding the appendicular skeleton. This finding corroborates previous results that showed that sigmodontines exhibit an all-purpose appendicular morphology that allows them to use and explore a great variety of habitats. © 2017 Anatomical Society.

  13. Rapid immunohistochemistry based on alternating current electric field for intraoperative diagnosis of brain tumors.

    PubMed

    Tanino, Mishie; Sasajima, Toshio; Nanjo, Hiroshi; Akesaka, Shiori; Kagaya, Masami; Kimura, Taichi; Ishida, Yusuke; Oda, Masaya; Takahashi, Masataka; Sugawara, Taku; Yoshioka, Toshiaki; Nishihara, Hiroshi; Akagami, Yoichi; Goto, Akiteru; Minamiya, Yoshihiro; Tanaka, Shinya

    2015-01-01

    Rapid immunohistochemistry (R-IHC) can contribute to the intraoperative diagnosis of central nervous system (CNS) tumors. We have recently developed a new IHC method based on an alternating current electric field to facilitate the antigen-antibody reaction. To ensure the requirement of R-IHC for intraoperative diagnosis, 183 cases of CNS tumors were reviewed regarding the accuracy rate of diagnosis without R-IHC. The diagnostic accuracy was 90.7 % (166/183 cases) [corrected] in which definitive diagnoses were not provided in 17 cases because of the failure of glioma grading and differential diagnosis of lymphoma and glioma. To establish the clinicopathological application, R-IHC for frozen specimens was compared with standard IHC for permanent specimens. 33 gliomas were analyzed, and the Ki-67/MIB-1 indices of frozen specimens by R-IHC were consistent with the grade and statistically correlated with those of permanent specimens. Thus, R-IHC provided supportive information to determine the grade of glioma. For discrimination between glioma and lymphoma, R-IHC was able to provide clear results of CD20 and Ki-67/MIB-1 in four frozen specimens of CNS lymphoma as well as standard IHC. We conclude that the R-IHC for frozen specimens can provide important information for intraoperative diagnosis of CNS tumors.

  14. A comparative study of the spatial distribution of mast cells and microvessels in the foetal, adult human thymus and thymoma.

    PubMed

    Raica, Marius; Cimpean, Anca Maria; Nico, Beatrice; Guidolin, Diego; Ribatti, Domenico

    2010-02-01

    Mast cells (MCs) are widely distributed in human and animal tissues and have been shown to play an important role in angiogenesis in normal and pathological conditions. Few data are available about the relationship between MCs and blood vessels in the normal human thymus, and there are virtually no data about their distribution and significance in thymoma. The aim of this study was to analyse the spatial distribution of MCs and microvessels in the normal foetal and adult thymus and thymoma. Twenty biopsy specimens of human thymus, including foetal and adult normal thymus and thymoma were analysed. Double staining with CD34 and mast cell tryptase was used to count both mast cells and microvessels in the same fields. Computer-assisted image analysis was performed to characterize the spatial distribution of MCs and blood vessels in selected specimens. Results demonstrated that MCs were localized exclusively to the medulla. Their number was significantly higher in thymoma specimens as compared with adult and foetal normal specimens respectively. In contrast the microvessel area was unchanged. The analysis of the spatial distribution and relationship between MCs and microvessels revealed that only in the thymoma specimens was there a significant spatial association between MCs and microvessels. Overall, these data suggest that MCs do not contribute significantly to the development of the vascular network in foetal and adult thymus, whereas in thymoma they show a close relationship to blood vessels. This could be an expression of their involvement not only in endothelial cells but also in tumour cell proliferation.

  15. Efficacy and safety of cryobiopsy versus forceps biopsy for interstitial lung diseases and lung tumours: A systematic review and meta-analysis.

    PubMed

    Ganganah, Oormila; Guo, Shu Liang; Chiniah, Manu; Li, Yi Shi

    2016-07-01

    Forceps biopsy (FB) is the most commonly used diagnostic tool for lung pathologies. FB is associated with a high diagnostic failure rate. Cryobiopsy (CB) is a novel technique providing a larger specimen size, few artefacts, more alveolar parts and superior diagnostic yield. CB, however, has drawbacks such as higher bleeding and pneumothorax rate. We conducted a meta-analysis to investigate the specimen area, diagnostic rate and bleeding severity in CB versus FB in interstitial lung diseases (ILDs) and lung tumours. A systematic literature search of PUBMED, BIOSIS PREVIEW and OVID databases was conducted using specific search terms. Eligible studies including RCTs and non-RCTs comparing cryobiopsy/cryotransbronchial biopsy (CB/CTBB) and forceps biopsy/forceps transbronchial biopsy (FB/FTBB) for specimen area, diagnostic rate and bleeding rate in ILDs and lung tumours were analysed. Two reviewers independently extracted data and evaluated the quality of the studies. Eight studies involving 916 patients were analysed. Specimen area (mm(2) ) was significantly larger in CB/CTBB than FB/FTBB (standard mean difference = 1.21, 95% confidence interval (0.94, 1.48), P < 0.00001). The diagnostic rate was significantly higher in CB/CTBB than FB/FTBB (Risk ratio 1.36, 95% confidence interval (1.16, 1.59), P = 0.0002). Three studies compared the bleeding severity with only one showing significantly more bleeding in CB. Cryobiopsy/cryotransbronchial shows superiority to FB/FTBB for specimen area and diagnostic rate. CB/CTBB has better efficacy over FB/FTBB. © 2016 Asian Pacific Society of Respirology.

  16. Three dimensional morphological studies of Larger Benthic Foraminifera at the population level using micro computed tomography

    NASA Astrophysics Data System (ADS)

    Kinoshita, Shunichi; Eder, Wolfgang; Woeger, Julia; Hohenegger, Johann; Briguglio, Antonino; Ferrandez-Canadell, Carles

    2015-04-01

    Symbiont-bearing larger benthic Foraminifera (LBF) are long-living marine (at least 1 year), single-celled organisms with complex calcium carbonate shells. Their morphology has been intensively studied since the middle of the nineteenth century. This led to a broad spectrum of taxonomic results, important from biostratigraphy to ecology in shallow water tropical to warm temperate marine palaeo-environments. However, it was necessary for the traditional investigation methods to cut or destruct specimens for analysing the taxonomically important inner structures. X-ray micro-computed tomography (microCT) is one of the newest techniques used in morphological studies. The greatest advantage is the non-destructive acquisition of inner structures. Furthermore, the running improve of microCT scanners' hard- and software provides high resolution and short time scans well-suited for LBF. Three-dimensional imaging techniques allow to select and extract each chamber and to measure easily its volume, surface and several form parameters used for morphometric analyses. Thus, 3-dimensional visualisation of LBF-tests is a very big step forward from traditional morphology based on 2-dimensional data. The quantification of chamber form is a great opportunity to tackle LBF structures, architectures and the bauplan geometry. The micrometric digital resolution is the only way to solve many controversies in phylogeny and evolutionary trends of LBF. For the present study we used micro-computed tomography to easily investigate the chamber number of every specimen from statistically representative part of populations to estimate population dynamics. Samples of living individuals are collected at monthly intervals from fixed locations. Specific preparation allows to scan up to 35 specimens per scan within 2 hours and to obtain the complete digital dataset for each specimen of the population. MicroCT enables thus a fast and precise count of all chambers built by the foraminifer from its birth until the time of collection and to extract selected chambers for further studies. The variation in chamber number during the sampling period (in this study limited at 15 months) will allow the estimation of the mean chamber building rate for each investigated species. However, a number of morphological aberrations within the population can be observed: often multiple proloculi are present; their orientation to the equatorial plane (or planes) respectively the spatial position of the foramina between proloculus (or proloculi) to the reniform deuteroloculi, the geometry of septa and septula and their variation trough ontogeny and several other ontogenetic variation need further attention. Many new insights into the biology of living and fossil LBF will be obtained when the three dimensional morphology of the complete foraminiferal shell is raised to the population level.

  17. Peri-implant assessment via cone beam computed tomography and digital periapical radiography: an ex vivo study.

    PubMed

    Silveira-Neto, Nicolau; Flores, Mateus Ericson; De Carli, João Paulo; Costa, Max Dória; Matos, Felipe de Souza; Paranhos, Luiz Renato; Linden, Maria Salete Sandini

    2017-11-01

    This research evaluated detail registration in peri-implant bone using two different cone beam computer tomography systems and a digital periapical radiograph. Three different image acquisition protocols were established for each cone beam computer tomography apparatus, and three clinical situations were simulated in an ex vivo fresh pig mandible: buccal bone defect, peri-implant bone defect, and bone contact. Data were subjected to two analyses: quantitative and qualitative. The quantitative analyses involved a comparison of real specimen measures using a digital caliper in three regions of the preserved buccal bone - A, B and E (control group) - to cone beam computer tomography images obtained with different protocols (kp1, kp2, kp3, ip1, ip2, and ip3). In the qualitative analyses, the ability to register peri-implant details via tomography and digital periapical radiography was verified, as indicated by twelve evaluators. Data were analyzed with ANOVA and Tukey's test (α=0.05). The quantitative assessment showed means statistically equal to those of the control group under the following conditions: buccal bone defect B and E with kp1 and ip1, peri-implant bone defect E with kp2 and kp3, and bone contact A with kp1, kp2, kp3, and ip2. Qualitatively, only bone contacts were significantly different among the assessments, and the p3 results differed from the p1 and p2 results. The other results were statistically equivalent. The registration of peri-implant details was influenced by the image acquisition protocol, although metal artifacts were produced in all situations. The evaluators preferred the Kodak 9000 3D cone beam computer tomography in most cases. The evaluators identified buccal bone defects better with cone beam computer tomography and identified peri-implant bone defects better with digital periapical radiography.

  18. Decreased expression of pyruvate dehydrogenase A1 predicts an unfavorable prognosis in ovarian carcinoma.

    PubMed

    Li, Yaqing; Huang, Ruixia; Li, Xiaoli; Li, Xiaoran; Yu, Dandan; Zhang, Mingzhi; Wen, Jianguo; Goscinski, Mariusz Adam; Trope, Claes G; Nesland, Jahn M; Suo, Zhenhe

    2016-01-01

    Pyruvate dehydrogenase A1 (PDHA1) serves as a gate-keeper enzyme link between glycolysis and the mitochondrial citric acid cycle. The inhibition of PDHA1 in cancer cells can result in an increased Warburg effect and a more aggressive phenotype in cancer cells. This study was conducted to investigate the expression of PDHA1 in ovarian cancer and the correlation between PDHA1 expression and the prognosis of patients. The PDHA1 protein expression in 3 ovarian cancer cell lines (OVCAR-3, SKOV-3 and ES-2) and 248 surgically removed ovarian carcinoma samples was immunocytochemically examined. Statistical analyses were performed to evaluate the correlations between PDHA1 expression and the clinicopathological characteristics of the patients as well as the predictive value of PDHA1. The results showed the presence of variable expression of PDHA1 in the three ovarian cancer cell lines. Of the 248 ovarian cancer tissue specimens, 45 cases (18.1%) were negative in tumor cells for PDHA1, 162 cases (65.3%) displayed a low expression level, and 41 cases (16.5%) had a relatively high PDHA1 staining. The expression of PDHA1 was associated with the histological subtype ( P =0.004) and FIGO stage ( P =0.002). The median OS time in the PDHA1 negative group, low expression group and high expression group were 0.939 years, 1.443 years and 9.900 years, respectively. The median PFS time in the above three groups were 0.287 years, 0.586 years and 9.900 years, respectively. Furthermore, the high expression of PDHA1 in ovarian carcinoma cells was significantly associated with better OS and PFS by statistical analyses. Multivariate analyses showed that PDHA1 expression was also an independent prognostic factor for higher OS in ovarian cancer patients (HR=0.705, 95% CI 0.541-0.918, P =0.01). Our study indicated that the decreased expression of PDHA1 might be an independent prognostic factor in unfavorable outcomes.

  19. Biomarker Signatures of Mitochondrial NDUFS3 in Invasive Breast Carcinoma

    PubMed Central

    Suhane, Sonal; Berel, Dror; Ramanujan, V Krishnan

    2011-01-01

    We present evidence for potential biomarker utility of a mitochondrial complex I subunit, (NDUFS3) in discriminating normal and highly invasive breast carcinoma specimens obtained from clinical patients. Besides being a robust indicator of breast cancer aggressiveness, NDUFS3 also shows clear signatures of a hypoxia/necrosis marker in invasive ductal carcinoma specimens. Statistically significant positive correlation was observed between nuclear grade and NDUFS3 expression level in the tumor specimens analyzed. We support these findings with a plausible mechanism involving mitochondrial complex I assembly defects and/or redox buffering induced mitochondrial dysfunction during the process of cancer cell transformation. From a clinical standpoint, this novel observation adds value in augmenting the current receptor-based biomarkers for better accuracy in diagnosis and predicting survival rate in patients with breast carcinoma. PMID:21867691

  20. A Practical Guide for the Preparation of Specimens for X-ray Fluorescence and X-ray Diffraction Analysis (by V. E. Buhrke, R. Jenkins, and D. K. Smith)

    NASA Astrophysics Data System (ADS)

    Rudman, Reuben

    1999-06-01

    Wiley-VCH: New York, 1998. xxiv + 333 pp. ISBN 0-471-19458-1. $79.95. I would have subtitled this book "All You Ever Wanted To Know about ...Sample Preparation". Although its principal thrust is geared towards the analytical chemist in an X-ray diffraction (XRD) or X-ray fluorescence (XRF) service laboratory, this text will be of use primarily as a reference source in all milieus dealing with undergraduate research projects and advanced laboratory courses in physical and analytical chemistry. It contains dozens of suggestions for preparing randomly oriented small samples of nearly anything. For example, rocks and minerals, soft organics and hard ceramics, radioactive and liquid materials, metals and oils are all treated. As the availability of XRD and XRF equipment has increased, so has the use of these techniques in the teaching schedule. Many undergraduate laboratory and research projects utilizing these methods have been described in the literature and are found in laboratory textbooks. Very often, especially with the increasingly common use of automated computer-controlled instrumentation, sample preparation has become the key experimental technique required for successful data collection. However, it is not always easy to prepare the statistically random distribution of small particles (crystallites) that is required by these methods. A multitude of techniques have been developed over the past 70 years, but many of them have been handed down by word of mouth or are scattered throughout the literature. This book represents an attempt to systematically describe the theory and practice of sample preparation. This excellent guide to the intricacies of sample preparation begins with a description of statistical sampling methods and the principles of grinding techniques. After a discussion of XRF specimen preparation, which includes pressing pellets, fusion methods, crucible selection and handling very small samples, detailed descriptions for handling rocks, minerals, cements, metals, oils, and vegetation [sic] are given. The preparation of XRD samples is described for various diffraction equipment geometries (utilizing both counter and film detectors), including specific information regarding the use of flat specimens and slurries, the use of internal standards, and the effects of crystallite size on the diffraction pattern. Methods for handling ceramics, clays, zeolites, air-sensitive samples, thin films, and plastics are described, along with the special handling requirements for materials to be studied by high-pressure, high-temperature, or low-temperature techniques. One whole chapter is devoted to the equipment used in specimen preparation, including grinders, pulverizers, presses, specimen holders, repair of platinumware, and sources of all types of special equipment. Did you ever want to know where to get a Plattner steel mortar or a micronizing mill or soft-glass capillary tubes with 0.01-mm wall thickness? It's all here in this monograph. The book ends with a good glossary of terms, a general bibliography in addition to the extensive list of references following each of its 9 chapters, and an index. It will be of help in many areas of spectroscopy and analytical chemistry, as well as in XRD and XRF analyses.

  1. Ultrasonic Evaluation and Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crawford, Susan L.; Anderson, Michael T.; Diaz, Aaron A.

    2015-10-01

    Ultrasonic evaluation of materials for material characterization and flaw detection is as simple as manually moving a single-element probe across a speci-men and looking at an oscilloscope display in real time or as complex as automatically (under computer control) scanning a phased-array probe across a specimen and collecting encoded data for immediate or off-line data analyses. The reliability of the results in the second technique is greatly increased because of a higher density of measurements per scanned area and measurements that can be more precisely related to the specimen geometry. This chapter will briefly discuss applications of the collection ofmore » spatially encoded data and focus primarily on the off-line analyses in the form of data imaging. Pacific Northwest National Laboratory (PNNL) has been involved with as-sessing and advancing the reliability of inservice inspections of nuclear power plant components for over 35 years. Modern ultrasonic imaging techniques such as the synthetic aperture focusing technique (SAFT), phased-array (PA) technolo-gy and sound field mapping have undergone considerable improvements to effec-tively assess and better understand material constraints.« less

  2. Human papillomavirus in normal conjunctival tissue and in conjunctival papilloma: types and frequencies in a large series.

    PubMed

    Sjö, Nicolai Christian; von Buchwald, Christian; Cassonnet, Patricia; Norrild, Bodil; Prause, Jan Ulrik; Vinding, Troels; Heegaard, Steffen

    2007-08-01

    To examine conjunctival papilloma and normal conjunctival tissue for the presence of human papillomavirus (HPV). Archival paraffin wax-embedded tissue from 165 conjunctival papillomas and from 20 histological normal conjunctival biopsy specimens was analysed for the presence of HPV by PCR. Specimens considered HPV positive using consensus primers, but with a negative or uncertain PCR result using type-specific HPV probes, were analysed with DNA sequencing. HPV was present in 86 of 106 (81%) beta-globin-positive papillomas. HPV type 6 was positive in 80 cases, HPV type 11 was identified in 5 cases and HPV type 45 was present in a single papilloma. All the 20 normal conjunctival biopsy specimens were beta-globin positive and HPV negative. There is a strong association between HPV and conjunctival papilloma. The study presents the largest material of conjunctival papilloma investigated for HPV and the first investigation of HPV in normal conjunctival tissue. HPV types 6 and 11 are the most common HPV types in conjunctival papilloma. This also is the first report of HPV type 45 in conjunctival papilloma.

  3. Characterization of a polymer-infiltrated ceramic-network material

    PubMed Central

    Corazza, Pedro H.; Zhang, Yu

    2015-01-01

    Objectives To characterize the microstructure and determine some mechanical properties of a polymer-ingfiltrated ceramic-network (PICN) material (Vita Enamic, Vita Zahnfabrik) available for CAD–CAM systems. Methods Specimens were fabricated to perform quantitative and qualitative analyses of the material’s microstructure and to determine the fracture toughness (KIc), density (ρ), Poisson’s ratio (v) and Young’s modulus (E). KIc was determined using V-notched specimens and the short beam toughness method, where bar-shaped specimens were notched and 3-point loaded to fracture. ρ was calculated using Archimedes principle, and v and E were measured using an ultrasonic thickness gauge with a combination of a pulse generator and an oscilloscope. Results Microstructural analyses showed a ceramic- and a polymer-based interpenetrating network. Mean and standard deviation values for the properties evaluated were: KIc = 1.09 ± 0.05 MPa m1/2, ρ = 2.09 ± 0.01 g/cm3, v = 0.23 ± 0.002 and E = 37.95 ± 0.34 GPa. Significance The PICN material showed mechanical properties between porcelains and resin-based composites, reflecting its microstructural components. PMID:24656471

  4. Characterization of a polymer-infiltrated ceramic-network material.

    PubMed

    Della Bona, Alvaro; Corazza, Pedro H; Zhang, Yu

    2014-05-01

    To characterize the microstructure and determine some mechanical properties of a polymer-infiltrated ceramic-network (PICN) material (Vita Enamic, Vita Zahnfabrik) available for CAD-CAM systems. Specimens were fabricated to perform quantitative and qualitative analyses of the material's microstructure and to determine the fracture toughness (KIc), density (ρ), Poisson's ratio (ν) and Young's modulus (E). KIc was determined using V-notched specimens and the short beam toughness method, where bar-shaped specimens were notched and 3-point loaded to fracture. ρ was calculated using Archimedes principle, and ν and E were measured using an ultrasonic thickness gauge with a combination of a pulse generator and an oscilloscope. Microstructural analyses showed a ceramic- and a polymer-based interpenetrating network. Mean and standard deviation values for the properties evaluated were: KIc=1.09±0.05MPam(1/2), ρ=2.09±0.01g/cm(3), ν=0.23±0.002 and E=37.95±0.34GPa. The PICN material showed mechanical properties between porcelains and resin-based composites, reflecting its microstructural components. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  5. Laser and Electrochemical Studies of Metallization in Electronic Devices

    DTIC Science & Technology

    1988-11-15

    3.14 AES Surface Analyses Profile at Laser Non-Irradiated Zone ...... ........... 47 Fig 3.15 AES Surface Analyses Profile at Laser Gold Deposit Zone...After Various Times of Ion Sputtering .... ............ ... 48 Fig 3.16 ESCA Surface Analyses Profile of Laser Gold Deposit Zone After Sputtering...57 Table 3.4 Resistance Measurement of Two Point Probes Laser Gold Line Deposits on Superconductive Specimen Material ..... . 58 Fig 3.19

  6. A Strategy for Helicobacter Immunohistochemistry Utilization in Pediatric Practice:  Insights From Morphologic and Cost-Benefit Analyses.

    PubMed

    Conces, Miriam R; Arnold, Christina A; Baker, Peter B; Carter, Christopher M; Fung, Bonita; Prasad, Vinay; Arnold, Michael A

    2016-11-01

    Recent studies in adults have examined the utility of immunohistochemistry (IHC) in detecting Helicobacter in gastric biopsy specimens and reached differing conclusions. Dedicated cost-benefit analysis of Helicobacter IHC in pediatric gastric biopsy specimens has not been performed. From 1,955 pediatric gastric biopsies in a 1-year period, we identified 63 Helicobacter -positive and 120 Helicobacter -negative biopsy specimens. All cases were scored according to the Updated Sydney System for the severity of inflammation. We observed that pediatric Helicobacter infection was significantly associated with germinal center formation, active inflammation, oxyntic mucosa with moderate to severe chronic inflammation, and antral mucosa with any chronic inflammation, exclusive of mild and superficial chronic inflammation. At least one associated pattern was seen in each Helicobacter -positive biopsy specimen. In comparison with adults, pediatric Helicobacter -positive biopsy specimens are more likely to lack acute inflammation and more likely to show moderate to marked chronic inflammation. We recommend performing Helicobacter IHC on pediatric gastric biopsy specimens with any of the above inflammatory patterns. This approach can sensitively identify pediatric patients with Helicobacter gastritis, limit IHC staining to approximately 30% of all gastric biopsy specimens, and reduce costs by up to $55,306.90 per 1,000 biopsy specimens. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  7. Maxillary canine morphology: comparative and descriptive analysis from periapical radiographs and cone beam computed tomography.

    PubMed

    Torres, Hianne Miranda de; Arruda, Julyanna Jacinto de; Silva-Filho, João Manoel da; Faria, Danielle Lago Bruno de; Nascimento, Monikelly Carmo Chagas; Torres, Érica Miranda de

    2017-01-01

    The anatomical characteristics of permanent maxillary canines were evaluated through visual examination, periapical radiography, and cone beam computed tomography (CBCT), and measurements obtained from the images and directly on the teeth were compared. Fifty extracted human maxillary canines were classified according to the side of the mouth. The direction of root curvature and location of the apical foramen were also verified. Periapical radiographs and CBCTs of the specimens were obtained. The number of root canals was verified. Tooth length and the mesiodistal and buccopalatal widths of the root were measured directly on the specimens as well as on the radiographs and CBCTs. Data were analyzed by chi-square testing and analysis of variance (α = 0.05). All teeth-26 (52%) from the right side of the dental arch and 24 (48%) from the left-had only 1 main canal each. The apical foramen was located exactly in the root apex in 34 teeth (68%). Root curvature toward the distal side was observed in the apical third in 23 teeth (46%). There were no statistically significant differences between the canines' arch side and either the foramen location (P = 0.104) or the root curvature (P = 0.215). No statistically significant differences were found in measurements of tooth length (P = 0.669), mesiodistal root width (P = 0.517), or buccopalatal root width (P = 0.672) obtained from specimens and images. Both CBCTs and periapical radiographs were reliable for determining the tooth length, mesiodistal root width, and buccopalatal root width of maxillary canines and produced statistically similar measurements.

  8. The Effect of Diode Laser With Different Parameters on Root Fracture During Irrigation Procedure.

    PubMed

    Karataş, Ertuğrul; Arslan, Hakan; Topçuoğlu, Hüseyin Sinan; Yılmaz, Cenk Burak; Yeter, Kübra Yesildal; Ayrancı, Leyla Benan

    2016-06-01

    The aim of this study is to compare the effect of a single diode laser application and agitation of EDTA with diode laser with different parameters at different time intervals on root fracture. Ninety mandibular incisors were instrumented except the negative control group. The specimens were divided randomly into 10 groups according to final irrigation procedure: (G1) non-instrumented; (G2) distilled water; (G3) 15% EDTA; (G4) ultrasonically agitated EDTA; (G5) single 1.5W/100 Hz Diode laser; (G6) single 3W/100 Hz Diode laser; (G7) 1.5W/100 Hz Diode laser agitation of EDTA for 20 s; (G8) 1.5W/100 Hz Diode laser agitation of EDTA for 40 s; (G9) 3W/100 Hz Diode laser agitation of EDTA for 20 s; and (G10) 3W/100 Hz Diode laser agitation of EDTA for 40 s. The specimens were filled, mounted in acrylic resin, and compression strength test was performed on each specimen. Statistical analysis was carried out using one way ANOVA and Tukey's post hoc tests (P = 0.05). The statistical analysis revealed that there were statistically significant differences among the groups (P < 0.05). Laser-agitated irrigation with a 3W/100 Hz Diode laser for both 20 s and 40 s decreased the fracture resistance of teeth. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  9. Regenerate Healing Outcomes in Unilateral Mandibular Distraction Osteogenesis Using Quantitative Histomorphometry

    PubMed Central

    Schwarz, Daniel A.; Arman, Krikor G.; Kakwan, Mehreen S.; Jamali, Ameen M.; Elmeligy, Ayman A.; Buchman, Steven R.

    2015-01-01

    Background The authors’ goal was to ascertain regenerate bone-healing metrics using quantitative histomorphometry at a single consolidation period. Methods Rats underwent either mandibular distraction osteogenesis (n=7) or partially reduced fractures (n=7); their contralateral mandibles were used as controls (n=11). External fixators were secured and unilateral osteotomies performed, followed by either mandibular distraction osteogenesis (4 days’ latency, then 0.3 mm every 12 hours for 8 days; 5.1 mm) or partially reduced fractures (fixed immediately postoperatively; 2.1 mm); both groups underwent 4 weeks of consolidation. After tissue processing, bone volume/tissue volume ratio, osteoid volume/tissue volume ratio, and osteocyte count per high-power field were analyzed by means of quantitative histomorphometry. Results Contralateral mandibles had statistically greater bone volume/tissue volume ratio and osteocyte count per high-power field compared with both mandibular distraction osteogenesis and partially reduced fractures by almost 50 percent, whereas osteoid volume/tissue volume ratio was statistically greater in both mandibular distraction osteogenesis specimens and partially reduced fractures compared with contralateral mandibles. No statistical difference in bone volume/tissue volume ratio, osteoid volume/tissue volume ratio, or osteocyte count per high-power field was found between mandibular distraction osteogenesis specimens and partially reduced fractures. Conclusions The authors’ findings demonstrate significantly decreased bone quantity and maturity in mandibular distraction osteogenesis specimens and partially reduced fractures compared with contralateral mandibles using the clinically analogous protocols. If these results are extrapolated clinically, treatment strategies may require modification to ensure reliable, predictable, and improved outcomes. PMID:20463629

  10. Modular Classification of Endoscopic Endonasal Transsphenoidal Approaches to Sellar Region: Anatomic Quantitative Study.

    PubMed

    Belotti, Francesco; Doglietto, Francesco; Schreiber, Alberto; Ravanelli, Marco; Ferrari, Marco; Lancini, Davide; Rampinelli, Vittorio; Hirtler, Lena; Buffoli, Barbara; Bolzoni Villaret, Andrea; Maroldi, Roberto; Rodella, Luigi Fabrizio; Nicolai, Piero; Fontanella, Marco Maria

    2018-01-01

    Endoscopic visualization does not necessarily correspond to an adequate working space. The need for balancing invasiveness and adequacy of sellar tumor exposure has recently led to the description of multiple endoscopic endonasal transsphenoidal approaches. Comparative anatomic data on these variants are lacking. We sought to quantitatively compare endoscopic endonasal transsphenoidal approaches to the sella and parasellar region, using the concept of "surgical pyramid." Four endoscopic transsphenoidal approaches were performed in 10 injected specimens: 1) hemisphenoidotomy; 2) transrostral; 3) extended transrostral (with superior turbinectomy); and 4) extended transrostral with posterior ethmoidectomy. ApproachViewer software (part of GTx-Eyes II, University Health Network, Toronto, Canada) with a dedicated navigation system was used to quantify the surgical pyramid volume, as well as exposure of sellar and parasellar areas. Statistical analyses were performed with Friedman's tests and Nemenyi's procedure. Hemisphenoidotomy provided limited exposure of the sellar area and a small working volume. A transrostral approach was necessary to expose the entire sella. Exposure of lateral parasellar areas required superior turbinectomy or posterior ethmoidectomy. The differences between each of the modules was statistically significant. The present study validates, from an anatomic point of view, a modular classification of endoscopic endonasal transsphenoidal approaches to the sellar region. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Surgical Specimen Management: A Descriptive Study of 648 Adverse Events and Near Misses.

    PubMed

    Steelman, Victoria M; Williams, Tamara L; Szekendi, Marilyn K; Halverson, Amy L; Dintzis, Suzanne M; Pavkovic, Stephen

    2016-12-01

    - Surgical specimen adverse events can lead to delays in treatment or diagnosis, misdiagnosis, reoperation, inappropriate treatment, and anxiety or serious patient harm. - To describe the types and frequency of event reports associated with the management of surgical specimens, the contributing factors, and the level of harm associated with these events. - A retrospective review was undertaken of surgical specimen adverse events and near misses voluntarily reported in the University HealthSystem Consortium Safety Intelligence Patient Safety Organization database by more than 50 health care facilities during a 3-year period (2011-2013). Event reports that involved surgical specimen management were reviewed for patients undergoing surgery during which tissue or fluid was sent to the pathology department. - Six hundred forty-eight surgical specimen events were reported in all stages of the specimen management process, with the most common events reported during the prelaboratory phase and, specifically, with specimen labeling, collection/preservation, and transport. The most common contributing factors were failures in handoff communication, staff inattention, knowledge deficit, and environmental issues. Eight percent of the events (52 of 648) resulted in either the need for additional treatment or temporary or permanent harm to the patient. - All phases of specimen handling and processing are vulnerable to errors. These results provide a starting point for health care organizations to conduct proactive risk analyses of specimen handling procedures and to design safer processes. Particular attention should be paid to effective communication and handoffs, consistent processes across care areas, and staff training. In addition, organizations should consider the use of technology-based identification and tracking systems.

  12. Factors influencing the time between onset of illness and specimen collection in the diagnosis of non-pregnancy associated listeriosis in England and Wales.

    PubMed

    Awofisayo-Okuyelu, Adedoyin; Verlander, Neville Q; Amar, Corinne; Elson, Richard; Grant, Kathie; Harris, John

    2016-06-24

    Listeriosis is an opportunistic bacterial infection caused by Listeria monocytogenes and predominantly affects people who are immunocompromised. Due to its severity and the population at risk, prompt clinical diagnosis and treatment of listeriosis is essential. A major step to making a clinical diagnosis is the collection of the appropriate specimen(s) for testing. This study explores factors that may influence the time between onset of illness and collection of specimen in order to inform clinical policy and develop necessary interventions. Enhanced surveillance data on non-pregnancy associated listeriosis in England and Wales between 2004 and 2013 were collected and analysed. The difference in days between onset of symptoms and collection of specimen was calculated and factors influencing the time difference were identified using a gamma regression model. The median number of days between onset of symptoms and collection of specimen was two days with 27.1 % of cases reporting one day between onset of symptoms and collection of specimen and 18.8 % of cases reporting more than seven days before collection of specimen. The median number of days between onset of symptoms and collection of specimen was shorter for cases infected with Listeria monocytogenes serogroup 1/2b (one day) and cases with an underlying condition (one day) compared with cases infected with serotype 4 (two days) and cases without underlying conditions (two days). Our study has shown that Listeria monocytogenes serotype and the presence of an underlying condition may influence the time between onset of symptoms and collection of specimen.

  13. 42 CFR 493.1495 - Standard; Testing personnel responsibilities.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... experience, and technical abilities. (b) Each individual performing high complexity testing must— (1) Follow the laboratory's procedures for specimen handling and processing, test analyses, reporting and...

  14. Morphological and molecular reassessment of graptemys oculifera and Graptemys flavimaculata (Testudines: Emydidae)

    USGS Publications Warehouse

    Ennen, J.R.; Kreiser, B.R.; Qualls, C.P.; Lovich, J.E.

    2010-01-01

    The turtle genus Graptemys consists of 15 recognized taxa, distinguished largely on the basis of pigmentation pattern (i.e., soft tissue and shell), head size, and shell morphology. However, phylogenetic studies have shown limited sequence divergence within the genus and between Graptemys oculifera and Graptemys flavimaculata relative to most other members of the Emydidae. Graptemys oculifera of the Pearl River drainage and G. flavimaculata of the Pascagoula River drainage have been recognized as species since 1890 and 1954, respectively. However, the description of G. flavimaculata was based on a limited number of morphological characters. Several of these characters overlap between G. flavimaculata and G. oculifera, and no attempt was made to test for significant morphological differentiation. In this study, we reevaluated the morphological and genetic distinctiveness of G. flavimaculata and G. oculifera with (1) multivariate statistical analyses of 44 morphological characters and (2) 1,560 bp of sequence data from two mitochondrial genes (control region and ND4). The morphological and molecular analyses produced incongruent results. The principal components analysis ordinations separated the two species along a pigmentation gradient with G. flavimaculata having more yellow pigmentation than G. oculifera. Likewise, clustering analyses separated the specimens into two distinct groups with little overlap between the species. Our mitochondrial data supported previous findings of limited genetic differentiation between the two species. However, the results of our morphological analyses, in conjunction with recently published nuclear gene sequence data, support the continued recognition of the two species. Copyright 2010 Society for the Study of Amphibians and Reptiles.

  15. The NCBI BioCollections Database

    PubMed Central

    Sharma, Shobha; Ciufo, Stacy; Starchenko, Elena; Darji, Dakshesh; Chlumsky, Larry; Karsch-Mizrachi, Ilene

    2018-01-01

    Abstract The rapidly growing set of GenBank submissions includes sequences that are derived from vouchered specimens. These are associated with culture collections, museums, herbaria and other natural history collections, both living and preserved. Correct identification of the specimens studied, along with a method to associate the sample with its institution, is critical to the outcome of related studies and analyses. The National Center for Biotechnology Information BioCollections Database was established to allow the association of specimen vouchers and related sequence records to their home institutions. This process also allows cross-linking from the home institution for quick identification of all records originating from each collection. Database URL: https://www.ncbi.nlm.nih.gov/biocollections PMID:29688360

  16. Treatment of singularities in a middle-crack tension specimen

    NASA Technical Reports Server (NTRS)

    Shivakumar, K. N.; Raju, I. S.

    1990-01-01

    A three-dimensional finite-element analysis of a middle-crack tension specimen subjected to mode I loading was performed to study the stress singularity along the crack front. The specimen was modeled using 20-node isoparametric elements with collapsed nonsingular elements at the crack front. The displacements and stresses from the analysis were used to estimate the power of singularities, by a log-log regression analysis, along the crack front. Analyses showed that finite-sized cracked bodies have two singular stress fields. Because of two singular stress fields near the free surface and the classical square root singularity elsewhere, the strain energy release rate appears to be an appropriate parameter all along the crack front.

  17. Analysis of fatigue, fatique-crack propagation, and fracture data. [design of metallic aerospace structural components

    NASA Technical Reports Server (NTRS)

    Jaske, C. E.; Feddersen, C. E.; Davies, K. B.; Rice, R. C.

    1973-01-01

    Analytical methods have been developed for consolidation of fatigue, fatigue-crack propagation, and fracture data for use in design of metallic aerospace structural components. To evaluate these methods, a comprehensive file of data on 2024 and 7075 aluminums, Ti-6A1-4V, and 300M and D6Ac steels was established. Data were obtained from both published literature and unpublished reports furnished by aerospace companies. Fatigue and fatigue-crack-propagation analyses were restricted to information obtained from constant-amplitude load or strain cycling of specimens in air at room temperature. Fracture toughness data were from tests of center-cracked tension panels, part-through crack specimens, and compact-tension specimens.

  18. Fixing Formalin: A Method to Recover Genomic-Scale DNA Sequence Data from Formalin-Fixed Museum Specimens Using High-Throughput Sequencing.

    PubMed

    Hykin, Sarah M; Bi, Ke; McGuire, Jimmy A

    2015-01-01

    For 150 years or more, specimens were routinely collected and deposited in natural history collections without preserving fresh tissue samples for genetic analysis. In the case of most herpetological specimens (i.e. amphibians and reptiles), attempts to extract and sequence DNA from formalin-fixed, ethanol-preserved specimens-particularly for use in phylogenetic analyses-has been laborious and largely ineffective due to the highly fragmented nature of the DNA. As a result, tens of thousands of specimens in herpetological collections have not been available for sequence-based phylogenetic studies. Massively parallel High-Throughput Sequencing methods and the associated bioinformatics, however, are particularly suited to recovering meaningful genetic markers from severely degraded/fragmented DNA sequences such as DNA damaged by formalin-fixation. In this study, we compared previously published DNA extraction methods on three tissue types subsampled from formalin-fixed specimens of Anolis carolinensis, followed by sequencing. Sufficient quality DNA was recovered from liver tissue, making this technique minimally destructive to museum specimens. Sequencing was only successful for the more recently collected specimen (collected ~30 ybp). We suspect this could be due either to the conditions of preservation and/or the amount of tissue used for extraction purposes. For the successfully sequenced sample, we found a high rate of base misincorporation. After rigorous trimming, we successfully mapped 27.93% of the cleaned reads to the reference genome, were able to reconstruct the complete mitochondrial genome, and recovered an accurate phylogenetic placement for our specimen. We conclude that the amount of DNA available, which can vary depending on specimen age and preservation conditions, will determine if sequencing will be successful. The technique described here will greatly improve the value of museum collections by making many formalin-fixed specimens available for genetic analysis.

  19. Epidermal growth factor expression in esophageal adenocarcinoma: a clinically relevant target?

    PubMed

    Harper, Nicholas; Li, Yan; Farmer, Russell; Martin, Robert C G

    2012-05-01

    There has been recent widespread enthusiasm in epidermal growth factor (EGFR) as a molecularly active target in esophageal adenocarcinoma (EAC). However, there is limited data on the extent of EGFR expression in EAC. Thus, the aim of this study was to evaluated EGFR, pErk1/2, and total Erk1/2 expression in malignant and benign specimens. Baseline expression of EGFR in the human normal squamous, Barrett's, and EAC cell lines were determined as well as after bile acid treatment and curcumin pretreatment. In addition, EGFR expression was also evaluated in 60 matched normal and malignant EAC resected specimens. The in vitro studies in the Het-1a, BarT, and OE19 cell lines failed to show any measurable expression of EGFR via Western blot technique. The marker serving as the positive control for the study, MnSOD, showed expression in each cell line for all three treatment regimens at approximately 24 kDa EGFR, showing moderate staining in the malignant tumor specimens and low staining in the benign tissue specimens. pErk1/2 showed low staining in the malignant tumor specimens and no staining in the benign tissue specimens. Total Erk1/2 showed high staining in both the malignant tumor specimens and benign tissue specimens. The differences in the mean staining scores for the malignant versus benign tissue specimens for pErk1/2 and total Erk1/2 are not statistically significant (p = 0.0726 and p = 0.7054, respectively). Thus, in conclusion, EGFR expression has been confirmed to be limited to non-existent in EAC and thus its use as a clinically active target is limited at best. Prior to the use of these expensive anti-EGFR therapies, confirmation of overexpression should be verified.

  20. Molecular epidemiology of human metapneumovirus in Ireland.

    PubMed

    Carr, Michael J; Waters, Allison; Fenwick, Fiona; Toms, Geoffrey L; Hall, William W; O'Kelly, Edwin

    2008-03-01

    Human metapneumovirus (hMPV) is a cause of respiratory illness ranging from wheezing to bronchiolitis and pneumonia in children. A quantitative real-time reverse-transcriptase polymerase chain reaction (RT-PCR) assay was developed for the detection of all four main genetic lineages of hMPV and employed to validate an indirect immunofluorescence (IF) assay to detect hMPV positive specimens. The IF assay detected 24 positives from a screen of 625 randomly selected pediatric respiratory specimens collected (3.8% prevalence). From this cohort of 625 specimens, 229 were also tested by real-time RT-PCR assay. This included the 24 IF positive specimens and 205 randomly selected specimens from both study periods. In addition to confirming all the IF positives, the real-time assay detected an additional six hMPV positive specimens giving rise to a combined prevalence of 4.8%. Phylogenetic analysis showed that hMPV subtypes A2b and B2 to be the most prevalent genotypes circulating in our population and surprisingly no hMPV subgroups A1 or B1 were detected during this study period. Based on this phylogenetic analysis, we propose the existence of sub-clusters of hMPV genotype B2 present in our population which we term subtypes B2a and B2b. The mean log 10 copies/ml of quantitative RT-PCR determinations from these 30 hMPV positive respiratory specimens was 6.35 (range = 4.44-8.15). Statistical analysis of quantitative RT-PCR determinations of viral load from these 30 respiratory specimens suggests that hMPV genotype B specimens have a higher viral load than hMPV genotype A isolates (P < 0.03).

  1. In vitro effectiveness of antimicrobial photodynamic therapy (APDT) using a 660 nm laser and malachite green dye in Staphylococcus aureus biofilms arranged on compact and cancellous bone specimens.

    PubMed

    Rosa, Luciano Pereira; da Silva, Francine Cristina; Nader, Sumaia Alves; Meira, Giselle Andrade; Viana, Magda Souza

    2014-11-01

    The aim of this study was to evaluate the in vitro effectiveness of antimicrobial photodynamic therapy (APDT) using a 660 nm visible laser combined with malachite green (MG) dye in the inactivation of Staphylococcus aureus (ATCC 25923) biofilms formed within compact and cancellous bone specimens. Specimens of 80 compact bones and 80 cancellous bones were contaminated with a standard suspension of S. aureus and incubated for 14 days at 37 °C to allow for the formation of biofilms. The specimens were divided into the following groups (n = 10) according to the treatment conditions: PS-L - (control - no treatment), PS+L - (only MG for 5 min), PS-L + 90 (only laser irradiation for 90 s), PS-L + 180 (only laser irradiation for 180 s), PS-L + 300 (only laser irradiation for 300 s), APDT90 (APDT for 90 s), APDT180 (APDT for 180 s), and APDT300 (APDT for 300 s). The findings were statistically analyzed using an ANOVA 5%. All of the experimental groups were significantly different from the control group for both the compact and cancellous bone specimens. The compact bone specimens that received APDT treatment (for either 90, 180, or 300 s) showed reductions in the log10 CFU/ml of S. aureus by a magnitude of 4 log10. Cancellous bone specimens treated with 300 s of APDT showed the highest efficacy, and these specimens had a reduction in S. aureus CFU/ml by a factor of 3 log10. APDT treatment using these proposed parameters in combination with MG was effective at inactivating S. aureus biofilms in compact and cancellous bone specimens.

  2. Statistics for NAEG: past efforts, new results, and future plans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gilbert, R.O.; Simpson, J.C.; Kinnison, R.R.

    A brief review of Nevada Applied Ecology Group (NAEG) objectives is followed by a summary of past statistical analyses conducted by Pacific Northwest Laboratory for the NAEG. Estimates of spatial pattern of radionuclides and other statistical analyses at NS's 201, 219 and 221 are reviewed as background for new analyses presented in this paper. Suggested NAEG activities and statistical analyses needed for the projected termination date of NAEG studies in March 1986 are given.

  3. [Expression of ATAD2 in different liver lesions and its clinical significance].

    PubMed

    Liu, F; Zhou, X; Ji, H H; Li, H; Xiang, F G

    2017-05-20

    Objective: To examine the expression of ATAD2 in different liver lesions and its clinical significance. Methods: ATAD2 expression in 60 hepatocellular carcinoma (HCC) surgical specimens (49 of which have concurrent liver cirrhosis), 43 HCC biopsy specimens, 2 high-grade liver dysplastic nodule specimens, 3 low-grade liver dysplastic nodule specimens, 50 liver cirrhosis tissue samples, and 20 normal liver tissue samples were measured using immunohistochemistry. The F-test, q-test, t-test, and chi-square test were used for statistical analysis of data. Results: ATAD2 was expressed in 56 HCC surgical specimens (93.33%), 35 HCC biopsy specimens (81.40%), and 2 high-grade liver dysplastic nodule specimens (2/2), but not in the low-grade liver dysplastic nodule, liver cirrhosis tissue, and normal liver tissue samples. The mean expression of ATAD2 was significantly higher in HCC tissues than in high-grade and low-grade liver dysplastic nodule tissues, liver cirrhosis tissue, and normal liver tissue ( F = 22.96, q = 3.138, 3.972, 12.272, and 9.101, respectively, all P < 0.01). There were no significant differences in the mean expression and positive expression rate of ATAD2 between HCC surgical and biopsy specimens ( t = 1.40, P > 0.05; χ ² = 3.47, P >0.05). Of the 35 HCC biopsy specimens that expressed ATAD2, the mean ATAD2 expression was ≥1% in 35 specimens (100%), ≥3% in 27 specimens (77.14%), and ≥5 % in 23 specimens (65.71%). In addition, among the pathological grade I-II HCC biopsy specimens, the mean ATAD2 expression was ≥1% in 28 specimens (100%), ≥3% in 22 specimens (62.86%), and ≥5% in 19 specimens (54.29%). Moreover, ATAD2 expression in HCC was associated with serum alpha-fetoprotein level, presence of hepatitis B virus surface antigen (HBsAg), and presence of concurrent liver cirrhosis ( t = 2.09, 2.30, and 2.18, respectively, all P < 0.05). Conclusion: ATAD2 may play an important role in HCC tumorigenesis, and may be involved in malignant transformation of cells. ATAD2 expression can be a valuable marker for differentiating the nature of lesions in liver biopsy tissues during clinical practice.

  4. Diversity and genetic distance in populations of Steindachnerina in the upper Paraná river floodplain of Brazil.

    PubMed

    Oliveira, A V; Prioli, A J; Prioli, S M A P; Pavanelli, C S; Júlio, H F; Panarari, R S

    2002-08-01

    Whereas four species of the genus Steindachnerina occur in the Paraná river basin, S. insculpta was the only endemic species of the region under analysis, which is the third lower section of the upper Paraná river. Among other factors, this species has been characterised by the absence of spots in the basal region of the dorsal fin. However, various specimens with this characteristic appeared in the region after the construction of the Itaipu Hydroelectric Plant in 1982. An analysis of the genetic variability of Steindachnerina populations with or without spots is provided. Specimens were collected in different sites of the floodplain of the upper Paraná river and samples were compared by random amplified polymorphic DNA (RAPD) technique and morphological analyses. Ninety-eight amplified loci with nine random primers were analysed in 19 specimens of each phenotype. Data for genetic distance showed great divergences between the two phenotypes and indicate two different species. Spotted specimens may be identified as S. brevipinna, found in the region downstream Sete Quedas Falls. The species must have overcome the geographical barrier during the building of the Itaipu hydroelectric dam that submerged the waterfalls and which became an obstacle between the upper and middle Paraná river some 150 km downstream. Since phenotypes do not share dominant alleles, absence of gene flow has been suggested.

  5. A combined RT-PCR and dot-blot hybridization method reveals the coexistence of SJNNV and RGNNV betanodavirus genotypes in wild meagre (Argyrosomus regius).

    PubMed

    Lopez-Jimena, B; Cherif, N; Garcia-Rosado, E; Infante, C; Cano, I; Castro, D; Hammami, S; Borrego, J J; Alonso, M C

    2010-10-01

    To detect the possible coexistence of striped jack nervous necrosis virus (SJNNV) and red-spotted grouper nervous necrosis virus (RGNNV) genotypes in a single fish, a methodology based on the combination of PCR amplification and blot hybridization has been developed and applied in this study. The degenerate primers designed for the PCR procedure target the T4 region within the capsid gene, resulting in the amplification of both genotypes. The subsequent hybridization of these amplification products with two different specific digoxigenin-labelled probes resulted in the identification of both genotypes separately. The application of the RT-PCR protocol to analyse blood samples from asymptomatic wild meagre (Argyrosomus regius) specimens has shown a 46.87% of viral nervous necrosis virus carriers. The combination of RT-PCR and blot hybridization increases the detection rate up to 90.62%, and, in addition, it has shown the coexistence of both genotypes in 18 out of the 32 specimens analysed (56.25%). This study reports the coexistence of betanodaviruses belonging to two different genotypes (SJNNV and RGNNV) in wild fish specimens. This is the first report demonstrating the presence of SJNNV and RGNNV genotypes in the same specimen. This study also demonstrates a carrier state in this fish species for the first time. © 2010 The Authors. Journal compilation © 2010 The Society for Applied Microbiology.

  6. Epizoanthus spp. associations revealed using DNA markers: a case study from Kochi, Japan.

    PubMed

    Reimer, James Davis; Hirose, Mamiko; Nishisaka, Taiki; Sinniger, Frederic; Itani, Gyo

    2010-09-01

    Zoanthids (Cnidaria, Hexacorallia) of the genus Epizoanthus are often found in association with other marine invertebrates, including gastropods and hermit crabs. However, little information exists on the specificity and nature of these associations due to a lack of investigation into Epizoanthus species diversity, and the taxonomy of Epizoanthus is therefore confused. In this study, analyses of morphological data (tentacle number, polyp size, etc) and molecular data (mitochondrial cytochrome oxidase subunit 1 = COI, 16S ribosomal DNA = 16S rDNA) were used to examine Epizoanthus specimens from Tosa Bay, Kochi, Japan. The Epizoanthus specimens were found on both live gastropods (Gemmula unedo) and hermit crabs (Paguristes palythophilus) inhabiting G. unedo and G. cosmoi shells. While morphological analyses did not show clear differences between examined specimens, both COI and mt 16S rDNA clearly divided the specimens into two groups, one associated only with hermit crabs (= Epizoanthus sp. C), and another associated only with living gastropods (= Epizoanthus sp. S). Unexpectedly, DNA sequences from both groups did not match with two previously reported Epizoanthus species from Japan (E. indicus, E. ramosus), indicating they both may be undescribed species. These results highlight the utility of DNA "barcoding" of unknown zoanthids, and will provide a foundation for re-examinations of Epizoanthus species diversity and specificity, which will be critical in understanding the evolution of these unique marine invertebrates.

  7. An investigation of the effect of scaling-induced surface roughness on bacterial adhesion in common fixed dental restorative materials.

    PubMed

    Checketts, Matthew R; Turkyilmaz, Ilser; Asar, Neset Volkan

    2014-11-01

    Bacterial plaque must be routinely removed from teeth, adjacent structures, and prostheses. However, the removal of this plaque can inadvertently increase the risk of future bacterial adhesion. The purpose of this investigation was to assess the change in the surface roughness of 3 different surfaces after dental prophylactic instrumentation and how this influenced bacterial adhesion. Forty specimens each of Type III gold alloy, lithium disilicate, and zirconia were fabricated in the same dimensions. The specimens were divided into 4 groups: ultrasonic scaler, stainless steel curette, prophylaxis cup, and control. Pretreatment surface roughness measurements were made with a profilometer. Surface treatments in each group were performed with a custom mechanical scaler. Posttreatment surface roughness values were measured. In turn, the specimens were inoculated with Streptococcus mutans, Lactobacillus acidophilus, and Actinomyces viscosus. Bacterial adhesion was assessed by rinsing the specimens with sterile saline to remove unattached cells. The specimens were then placed in sterile tubes with 1 mL of sterile saline. The solution was plated and quantified. Scanning electron microscopy was performed. The statistical analysis of surface roughness was completed by using repeated-measures single-factor ANOVA with a Bonferroni correction. The surface roughness values for gold alloy specimens increased as a result of prophylaxis cup treatment (0.221 to 0.346 Ra) (P<.01) and stainless steel curette treatment (0.264 to 1.835 Ra) (P<.01). The results for bacterial adhesion to gold alloy proved inconclusive. A quantitative comparison indicated no statistically significant differences in pretreatment and posttreatment surface roughness values for lithium disilicate and zirconia specimens. In spite of these similarities, the overall bacterial adherence values for lithium disilicate were significantly greater than those recorded for gold alloy or zirconia (P<.05). Instrumentation of the lithium disilicate and zirconia with the stainless steel curette significantly increased bacterial adhesion compared with the control (P<.05). The results of this investigation indicate that Type III gold alloy exhibited increased surface roughness values after stainless steel curette and prophylaxis cup treatments. Zirconia was less susceptible to bacterial adhesion than lithium disilicate, and greater bacterial adhesion was found for the stainless steel curette than the other instrumentation methods. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. Expression of p53, p21 and cyclin D1 in penile cancer: p53 predicts poor prognosis.

    PubMed

    Gunia, Sven; Kakies, Christoph; Erbersdobler, Andreas; Hakenberg, Oliver W; Koch, Stefan; May, Matthias

    2012-03-01

    To evaluate the role of p53, p21 and cyclin D1 expression in patients with penile cancer (PC). Paraffin-embedded tissues from PC specimens from six pathology departments were subjected to a central histopathological review performed by one pathologist. The tissue microarray technique was used for immunostaining which was evaluated by two independent pathologists and correlated with cancer-specific survival (CSS). κ-statistics were used to assess interobserver variability. Uni- and multivariable Cox proportional hazards analysis was applied to assess the independent effects of several prognostic factors on CSS over a median of 32 months (IQR 6-66 months). Specimens and clinical data from 110 men treated surgically for primary PC were collected. p53 staining was positive in 30 and negative in 62 specimens. κ-statistics showed substantial interobserver reproducibility of p53 staining evaluation (κ=0.73; p<0.001). The 5-year CSS rate for the entire study cohort was 74%. Five-year CSS was 84% in p53-negative and 51% in p53-positive PC patients (p=0.003). Multivariable analysis showed p53 (HR=3.20; p=0.041) and pT-stage (HR=4.29; p<0.001) as independent significant prognostic factors for CSS. Cyclin D1 and p21 expression were not correlated with survival. However, incorporating p21 into a multivariable Cox model did contribute to improved model quality for predicting CSS. In patients with PC, the expression of p53 in the primary tumour specimen can be reproducibly assessed and is negatively associated with cancer specific survival.

  9. Does ozone enhance the remineralizing potential of nanohydroxyapatite on artificially demineralized enamel? A laser induced fluorescence study

    NASA Astrophysics Data System (ADS)

    Srinivasan, Samuelraj; Prabhu, Vijendra; Chandra, Subhash; Koshy, Shalini; Acharya, Shashidhar; Mahato, Krishna K.

    2014-02-01

    The present era of minimal invasive dentistry emphasizes the early detection and remineralization of initial enamel caries. Ozone has been shown to reverse the initial demineralization before the integrity of the enamel surface is lost. Nano-hydroxyapatite is a proven remineralizing agent for early enamel caries. In the present study, the effect of ozone in enhancing the remineralizing potential of nano-hydroxyapatite on artificially demineralized enamel was investigated using laser induced fluorescence. Thirty five sound human premolars were collected from healthy subjects undergoing orthodontic treatment. Fluorescence was recorded by exciting the mesial surfaces using 325 nm He-Cd laser with 2 mW power. Tooth specimens were subjected to demineralization to create initial enamel caries. Following which the specimens were divided into three groups, i.e ozone (ozonated water for 2 min), without ozone and artificial saliva. Remineralization regimen was followed for 3 weeks. The fluorescence spectra of the specimens were recorded from all the three experimental groups at baseline, after demineralization and remineralization. The average spectrum for each experimental group was used for statistical analysis. Fluorescence intensities of Ozone treated specimens following remineralization were higher than that of artificial saliva, and this difference was found to be statistically significant (P<0.0001). In a nutshell, ozone enhanced the remineralizing potential of nanohydroxyapatite, and laser induced fluorescence was found to be effective in assessing the surface mineral changes in enamel. Ozone can be considered an effective agent in reversing the initial enamel caries there by preventing the tooth from entering into the repetitive restorative cycle.

  10. Fracture resistance of endodontically treated teeth restored with a bulkfill flowable material and a resin composite

    PubMed Central

    Isufi, Almira; Plotino, Gianluca; Grande, Nicola Maria; Ioppolo, Pietro; Testarelli, Luca; Bedini, Rossella; Al-Sudani, Dina; Gambarini, Gianluca

    2016-01-01

    Summary Aim To determine and compare the fracture resistance of endodontically treated teeth restored with a bulk fill flowable material (SDR) and a traditional resin composite. Methods Thirty maxillary and 30 mandibular first molars were selected based on similar dimensions. After cleaning, shaping and filling of the root canals and adhesive procedures, specimens were assigned to 3 subgroups for each tooth type (n=10): Group A: control group, including intact teeth; Group B: access cavities were restored with a traditional resin composite (EsthetX; Dentsply-Italy, Rome, Italy); Group C: access cavities were restored with a bulk fill flowable composite (SDR; Dentsply-Italy), except 1.5 mm layer of the occlusal surface that was restored with the same resin composite as Group B. The specimens were subjected to compressive force in a material static-testing machine until fracture occurred, the maximum fracture load of the specimens was measured (N) and the type of fracture was recorded as favorable or unfavorable. Data were statistically analyzed with one-way analysis of variance (ANOVA) and Bonferroni tests (P<0.05). Results No statistically significant differences were found among groups (P<0.05). Fracture resistance of endodontically treated teeth restored with a traditional resin composite and with a bulk fill flowable composite (SDR) was similar in both maxillary and mandibular molars and showed no significant decrease in fracture resistance compared to intact specimens. Conclusions No significant difference was observed in the mechanical fracture resistance of endodontically treated molars restored with traditional resin composite restorations compared to bulk fill flowable composite restorations. PMID:27486505

  11. The effect of glazing and aging on the surface properties of CAD/CAM resin blocks

    PubMed Central

    Tuncer, Safa; Kara, Dilan; Demirci, Mustafa

    2018-01-01

    PURPOSE To investigate the effect of accelerated aging on surface properties of glazed CAD/CAM resin blocks using a 2D surface profilometer and a 3D non-contact optical profilometer. MATERIALS AND METHODS Three types of CAD/CAM resin restorative materials, LAVA Ultimate (3M ESPE, St Paul, MN, USA), VITA Enamic (Vita Zahnfabrik H. Rauter, Bad Säckingen, Germany), and Cerasmart (GC Corparation, Tokyo, Japan) were used for this study. CAD/CAM blocks were cut in 3-mm thickness slabs and divided into three groups; Group 1: control group (specimens polished with 600 grit SCI paper); Group 2: specimens sandblasted, silanized, and glazed with Optiglaze Color (GC); Group 3: glazed specimens subjected to 5000 thermocycles (n=15). The surface roughness (Ra and Rz) was evaluated using a profilometer and a 3D scanning instrument. Data were analyzed using two-way ANOVA and Tukey's post-hoc test (P<.05). RESULTS LAVA, VITA, and Cerasmart exhibited statistically similar Ra and Rz values for each group (P>.05). For VITA and Cerasmart, the specimens in Group 1 exhibited significantly higher Ra values than Group 2 (P<.05). Group 1 (0.502 Ra), Group 2 (0.384 Ra), and Group 3 (0.431 Ra) exhibited statistically similar Ra values for LAVA (P=.062). After 5000 thermocycles, surface roughness values did not change significantly for glazed LAVA, VITA, and Cerasmart (P>.05). CONCLUSION Glaze material Optiglaze Color makes CAD/CAM resin surfaces smooth and glazed CAD/CAM surfaces seem resistant to deterioration under 5000 thermocycles. PMID:29503714

  12. The effect of glazing and aging on the surface properties of CAD/CAM resin blocks.

    PubMed

    Tekçe, Neslihan; Fidan, Sinan; Tuncer, Safa; Kara, Dilan; Demirci, Mustafa

    2018-02-01

    To investigate the effect of accelerated aging on surface properties of glazed CAD/CAM resin blocks using a 2D surface profilometer and a 3D non-contact optical profilometer. Three types of CAD/CAM resin restorative materials, LAVA Ultimate (3M ESPE, St Paul, MN, USA), VITA Enamic (Vita Zahnfabrik H. Rauter, Bad Säckingen, Germany), and Cerasmart (GC Corparation, Tokyo, Japan) were used for this study. CAD/CAM blocks were cut in 3-mm thickness slabs and divided into three groups; Group 1: control group (specimens polished with 600 grit SCI paper); Group 2: specimens sandblasted, silanized, and glazed with Optiglaze Color (GC); Group 3: glazed specimens subjected to 5000 thermocycles (n=15). The surface roughness (R a and R z ) was evaluated using a profilometer and a 3D scanning instrument. Data were analyzed using two-way ANOVA and Tukey's post-hoc test ( P <.05). LAVA, VITA, and Cerasmart exhibited statistically similar R a and R z values for each group ( P >.05). For VITA and Cerasmart, the specimens in Group 1 exhibited significantly higher R a values than Group 2 ( P <.05). Group 1 (0.502 R a ), Group 2 (0.384 R a ), and Group 3 (0.431 R a ) exhibited statistically similar R a values for LAVA ( P =.062). After 5000 thermocycles, surface roughness values did not change significantly for glazed LAVA, VITA, and Cerasmart ( P >.05). Glaze material Optiglaze Color makes CAD/CAM resin surfaces smooth and glazed CAD/CAM surfaces seem resistant to deterioration under 5000 thermocycles.

  13. Comparison between Fluoride and Nano-hydroxyapatite in Remineralizing Initial Enamel Lesion: An in vitro Study.

    PubMed

    Daas, Issa; Badr, Sherine; Osman, Essam

    2018-03-01

    The aim of this study was to compare the effectiveness of nano-hydroxyapatite (nano-HAP) paste and fluoride varnish in remineralizing initial enamel lesion in young permanent teeth and their ability to resist secondary caries under dynamic pH cycling quantitatively and qualitatively. Initial caries-like lesions were artificially developed on 45 specimens. Specimens were divided into three groups: (1) Control (without treatment), (2) fluoride varnish (3M ESPE), and (3) nano-HAP paste (Desensibilize Nano P). The nano-HAP paste was applied twice separated by one pH cycle, and the varnish was applied only once followed by 7 days of pH cycling. All specimens were examined using DIAGNOdent® pen (KaVo, Germany), and a representative specimen was randomly selected from each group for qualitative evaluation using scanning electron microscope (SEM) at four stages: Baseline, after lesion formation, immediately after remineralization, and after pH cycling. Data were statistically analyzed with Statistical Package for the Social Sciences (SPSS), version 20. The degree of demineralization was significantly elevated in control group; however, no significant difference was found between fluoride varnish group and nano-HAP paste group (p < 0.001). Nano-HAP paste showed promising long-term protective effect in terms of surface depositions and maintaining a smooth surface compared with fluoride varnish. Based on the findings of this study, nano-HAP paste might be recommended as alternative remineralizing agent with lower fluoride concentration than fluoride varnish that could be beneficial for children, pregnant females, and those who are at high risk of dental fluorosis.

  14. The Effect on the Flexural Strength, Flexural Modulus and Compressive Strength of Fibre Reinforced Acrylic with That of Plain Unfilled Acrylic Resin – An in Vitro Study

    PubMed Central

    Thomas, Tony C; K, Aswini Kumar; Krishnan, Vinod; Mathew, Anil; V, Manju

    2015-01-01

    Aim: The aim of this in vitro study was to compare the flexural strength, the flexural modulus and compressive strength of the acrylic polymer reinforced with glass, carbon, polyethylene and Kevlar fibres with that of plain unfilled resin. Materials and Methods: A total of 50 specimens were prepared and divided into 10 specimens each under 5 groups namely group 1- control group without any fibres, group 2 – carbon fibres, group 3- glass fibres, group 4 – polyethylene, group 5- Kevlar. Universal testing machine (Tinius olsen, USA) was used for the testing of these specimens. Out of each group, 5 specimens were randomly selected and testing was done for flexural strength using a three point deflection test and three point bending test for compressive strength and the modulus was plotted using a graphical method. Statistical analysis was done using statistical software. Results: The respective mean values for samples in regard to their flexural strength for PMMA plain, PMMA+ glass fibre, PMMA+ carbon, PMMA+ polyethylene and PMMA+ Kevlar were 90.64, 100.79, 102.58, 94.13 and 96.43 respectively. Scheffes post hoc test clearly indicated that only mean flexural strength values of PMMA + Carbon, has the highest mean value. One-way ANOVA revealed a non-significant difference among the groups in regard to their compressive strength. Conclusion: The study concludes that carbon fibre reinforced samples has the greatest flexural strength and greatest flexural modulus, however the compressive strength remains unchanged. PMID:25954696

  15. Fracture resistance of endodontically treated teeth restored with a bulkfill flowable material and a resin composite.

    PubMed

    Isufi, Almira; Plotino, Gianluca; Grande, Nicola Maria; Ioppolo, Pietro; Testarelli, Luca; Bedini, Rossella; Al-Sudani, Dina; Gambarini, Gianluca

    2016-01-01

    To determine and compare the fracture resistance of endodontically treated teeth restored with a bulk fill flowable material (SDR) and a traditional resin composite. Thirty maxillary and 30 mandibular first molars were selected based on similar dimensions. After cleaning, shaping and filling of the root canals and adhesive procedures, specimens were assigned to 3 subgroups for each tooth type (n=10): Group A: control group, including intact teeth; Group B: access cavities were restored with a traditional resin composite (EsthetX; Dentsply-Italy, Rome, Italy); Group C: access cavities were restored with a bulk fill flowable composite (SDR; Dentsply-Italy), except 1.5 mm layer of the occlusal surface that was restored with the same resin composite as Group B. The specimens were subjected to compressive force in a material static-testing machine until fracture occurred, the maximum fracture load of the specimens was measured (N) and the type of fracture was recorded as favorable or unfavorable. Data were statistically analyzed with one-way analysis of variance (ANOVA) and Bonferroni tests (P<0.05). No statistically significant differences were found among groups (P<0.05). Fracture resistance of endodontically treated teeth restored with a traditional resin composite and with a bulk fill flowable composite (SDR) was similar in both maxillary and mandibular molars and showed no significant decrease in fracture resistance compared to intact specimens. No significant difference was observed in the mechanical fracture resistance of endodontically treated molars restored with traditional resin composite restorations compared to bulk fill flowable composite restorations.

  16. Comparison of the gas-liquid dual support fixation and Heitzman fixation techniques for preparing lung specimens

    PubMed Central

    Yu, Dongsheng; Qu, Weili; Xia, Haipeng; Li, Xiaofeng; Luan, Zhenfeng; Yan, Renjie; Lu, Xiaodong; Zhao, Peng

    2017-01-01

    The aim of the present study was to compare the gas-liquid dual support fixation and Heitzman fixation techniques for the preparation of lung specimens. A total of 40 fresh lung samples were surgically collected from 40 male patients with lung cancer by biopsy. Patients were recruited from the Affiliated Hospital of Qingdao University Medical College (Qingdao, China) between July 2007 and June 2014. Samples were prepared using either the gas-liquid dual support fixation method (group A; n=26) or the Heitzman fixation method (group B; n=14). High-resolution computed tomography (HRCT) scanning was performed prior to surgery and corresponding postoperative HRCT scanning was conducted for the lung specimens; the gross transverse specimen section, cord photography images and histological sections were evaluated. Morphological observations of lung specimens indicated that there were 22 cases in group A with grade I (84.6%) and 4 cases with grade II (15.4%), whereas, in group B, there were 5 cases with grade II (35.7%) and 9 cases with grade III (64.3%). Statistical analysis demonstrated that the grades of specimens between the two groups were significantly different (P<0.01). Results from imaging and histological studies found that the quality of lung specimens was superior in group A, compared with group B. In conclusion, the present study demonstrated that, compared with the Heitzman fixation method, gas-liquid dual support fixation may be a superior technique for the preparation of lung specimens. This finding may facilitate the improvement of lung HRCT and pathological studies. PMID:28673006

  17. Surface discoloration of composite resins: Effects of staining and bleaching.

    PubMed

    Poggio, Claudio; Beltrami, Riccardo; Scribante, Andrea; Colombo, Marco; Chiesa, Marco

    2012-09-01

    The purpose of this in vitro study was to evaluate surface discoloration of three microhybrid composite resins (Esthet•X HD, Clearfil AP-X, Gradia Direct) and five nanohybrid composite resins (Ceram•X, GC Kalore, G-aenial, Grandio, GrandioSO), after staining and bleaching procedures. The composite resins were polymerized with a curing light (Celalux II, Voco, Cuxhaven, Germany) into 160 silicon molds (6,4 mm in diameter and 2 mm in thickness) to obtain identical specimens. Twenty samples for each composite resin were prepared. The specimens were polished using an automated polishing machine with the sequence of 600-, 800-, 1000-grit abrasive paper under water irrigation. The specimens were immersed in tea and distilled water: the specimens were dipped for 20 min, once a day (every 24 h), for 14 days into the drinks. The specimens were then bleached with carbamide peroxide at 17% (Perfect Bleach-Voco). The color of specimens was measured with a spectrophotometer according to the CIE L(*)a(*)b(*) system after light-polymerization of composite resin specimens, after 7 days, after 14 days, and after bleaching. The color difference h index (DEab(*)) between each measurement was calculated. Statistical analysis was made using analysis of variance (ANOVA). All specimens showed a significant increase in staining with a similar trend and no significant differences between microhybrid and nanohybrid composite resins. After whitening procedures, materials tested showed both significant and unsignificant differences of the h index. Microhybrid and nanohybrid composite resins had similar in vitro surface discoloration in tea. After bleaching, discoloration was removed from some composite resins tested.

  18. Surface discoloration of composite resins: Effects of staining and bleaching

    PubMed Central

    Poggio, Claudio; Beltrami, Riccardo; Scribante, Andrea; Colombo, Marco; Chiesa, Marco

    2012-01-01

    Background: The purpose of this in vitro study was to evaluate surface discoloration of three microhybrid composite resins (Esthet•X HD, Clearfil AP-X, Gradia Direct) and five nanohybrid composite resins (Ceram•X, GC Kalore, G-aenial, Grandio, GrandioSO), after staining and bleaching procedures. Materials and Methods: The composite resins were polymerized with a curing light (Celalux II, Voco, Cuxhaven, Germany) into 160 silicon molds (6,4 mm in diameter and 2 mm in thickness) to obtain identical specimens. Twenty samples for each composite resin were prepared. The specimens were polished using an automated polishing machine with the sequence of 600-, 800-, 1000-grit abrasive paper under water irrigation. The specimens were immersed in tea and distilled water: the specimens were dipped for 20 min, once a day (every 24 h), for 14 days into the drinks. The specimens were then bleached with carbamide peroxide at 17% (Perfect Bleach-Voco). The color of specimens was measured with a spectrophotometer according to the CIE L*a*b* system after light-polymerization of composite resin specimens, after 7 days, after 14 days, and after bleaching. The color difference h index (DEab*) between each measurement was calculated. Statistical analysis was made using analysis of variance (ANOVA). Results: All specimens showed a significant increase in staining with a similar trend and no significant differences between microhybrid and nanohybrid composite resins. After whitening procedures, materials tested showed both significant and unsignificant differences of the h index. Conclusions: Microhybrid and nanohybrid composite resins had similar in vitro surface discoloration in tea. After bleaching, discoloration was removed from some composite resins tested. PMID:23559921

  19. Comparison of the gas-liquid dual support fixation and Heitzman fixation techniques for preparing lung specimens.

    PubMed

    Yu, Dongsheng; Qu, Weili; Xia, Haipeng; Li, Xiaofeng; Luan, Zhenfeng; Yan, Renjie; Lu, Xiaodong; Zhao, Peng

    2017-07-01

    The aim of the present study was to compare the gas-liquid dual support fixation and Heitzman fixation techniques for the preparation of lung specimens. A total of 40 fresh lung samples were surgically collected from 40 male patients with lung cancer by biopsy. Patients were recruited from the Affiliated Hospital of Qingdao University Medical College (Qingdao, China) between July 2007 and June 2014. Samples were prepared using either the gas-liquid dual support fixation method (group A; n=26) or the Heitzman fixation method (group B; n=14). High-resolution computed tomography (HRCT) scanning was performed prior to surgery and corresponding postoperative HRCT scanning was conducted for the lung specimens; the gross transverse specimen section, cord photography images and histological sections were evaluated. Morphological observations of lung specimens indicated that there were 22 cases in group A with grade I (84.6%) and 4 cases with grade II (15.4%), whereas, in group B, there were 5 cases with grade II (35.7%) and 9 cases with grade III (64.3%). Statistical analysis demonstrated that the grades of specimens between the two groups were significantly different (P<0.01). Results from imaging and histological studies found that the quality of lung specimens was superior in group A, compared with group B. In conclusion, the present study demonstrated that, compared with the Heitzman fixation method, gas-liquid dual support fixation may be a superior technique for the preparation of lung specimens. This finding may facilitate the improvement of lung HRCT and pathological studies.

  20. Waterborne toxoplasmosis investigated and analysed under hydrogeological assessment: new data and perspectives for further research

    PubMed Central

    Vieira, Flávia Pereira; Alves, Maria da Glória; Martins, Livia Mattos; Rangel, Alba Lucínia Peixoto; Dubey, Jitender Prakash; Hill, Dolores; Bahia-Oliveira/, Lilian Maria Garcia

    2015-01-01

    We present a set of data on human and chicken Toxoplasma gondii seroprevalence that was investigated and analysed in light of groundwater vulnerability information in an area endemic for waterborne toxoplasmosis in Brazil. Hydrogeological assessment was undertaken to select sites for water collection from wells for T. gondii oocyst testing and for collecting blood from free-range chickens and humans for anti-T. gondii serologic testing. Serologic testing of human specimens was done using conventional commercial tests and a sporozoite-specific embryogenesis-related protein (TgERP), which is able to differentiate whether infection resulted from tissue cysts or oocysts. Water specimens were negative for the presence of viable T. gondii oocysts. However, seroprevalence in free-range chickens was significantly associated with vulnerability of groundwater to surface contamination (p < 0.0001; odds ratio: 4.73, 95% confidence interval: 2.18-10.2). Surprisingly, a high prevalence of antibodies against TgERP was detected in human specimens, suggesting the possibility of a continuous contamination of drinking water with T. gondii oocysts in this endemic setting. These findings and the new proposed approach to investigate and analyse endemic toxoplasmosis in light of groundwater vulnerability information associated with prevalence in humans estimated by oocyst antigens recognition have implications for the potential role of hydrogeological assessment in researching waterborne toxoplasmosis at a global scale. PMID:26560984

  1. TAKASAGO-6 apparatus for cryogenic coherent X-ray diffraction imaging of biological non-crystalline particles using X-ray free electron laser at SACLA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kobayashi, Amane; Sekiguchi, Yuki; Oroguchi, Tomotaka

    Coherent X-ray diffraction imaging (CXDI) is a technique for structure analyses of non-crystalline particles with dimensions ranging from micrometer to sub-micrometer. We have developed a diffraction apparatus named TAKASAGO-6 for use in single-shot CXDI experiments of frozen-hydrated non-crystalline biological particles at cryogenic temperature with X-ray free electron laser pulses provided at a repetition rate of 30 Hz from the SPring-8 Angstrom Compact free-electron LAser. Specimen particles are flash-cooled after being dispersed on thin membranes supported by specially designed disks. The apparatus is equipped with a high-speed translation stage with a cryogenic pot for raster-scanning of the disks at a speedmore » higher than 25 μm/33 ms. In addition, we use devices assisting the easy transfer of cooled specimens from liquid-nitrogen storages to the cryogenic pot. In the current experimental procedure, more than 20 000 diffraction patterns can be collected within 1 h. Here we report the key components and performance of the diffraction apparatus. Based on the efficiency of the diffraction data collection and the structure analyses of metal particles, biological cells, and cellular organelles, we discuss the future application of this diffraction apparatus for structure analyses of biological specimens.« less

  2. Waterborne toxoplasmosis investigated and analysed under hydrogeological assessment: new data and perspectives for further research.

    PubMed

    Vieira, Flávia Pereira; Alves, Maria da Glória; Martins, Livia Mattos; Rangel, Alba Lucínia Peixoto; Dubey, Jitender Prakash; Hill, Dolores; Bahia-Oliveira, Lilian Maria Garcia

    2015-11-01

    We present a set of data on human and chicken Toxoplasma gondii seroprevalence that was investigated and analysed in light of groundwater vulnerability information in an area endemic for waterborne toxoplasmosis in Brazil. Hydrogeological assessment was undertaken to select sites for water collection from wells for T. gondii oocyst testing and for collecting blood from free-range chickens and humans for anti-T. gondii serologic testing. Serologic testing of human specimens was done using conventional commercial tests and a sporozoite-specific embryogenesis-related protein (TgERP), which is able to differentiate whether infection resulted from tissue cysts or oocysts. Water specimens were negative for the presence of viable T. gondii oocysts. However, seroprevalence in free-range chickens was significantly associated with vulnerability of groundwater to surface contamination (p < 0.0001; odds ratio: 4.73, 95% confidence interval: 2.18-10.2). Surprisingly, a high prevalence of antibodies against TgERP was detected in human specimens, suggesting the possibility of a continuous contamination of drinking water with T. gondii oocysts in this endemic setting. These findings and the new proposed approach to investigate and analyse endemic toxoplasmosis in light of groundwater vulnerability information associated with prevalence in humans estimated by oocyst antigens recognition have implications for the potential role of hydrogeological assessment in researching waterborne toxoplasmosis at a global scale.

  3. Evaluation of Surface Roughness and Tensile Strength of Base Metal Alloys Used for Crown and Bridge on Recasting (Recycling).

    PubMed

    Agrawal, Amit; Hashmi, Syed W; Rao, Yogesh; Garg, Akanksha

    2015-07-01

    Dental casting alloys play a prominent role in the restoration of the partial dentition. Casting alloys have to survive long term in the mouth and also have the combination of structure, molecules, wear resistance and biologic compatibility. According to ADA system casting alloys were divided into three groups (wt%); high noble, Noble and predominantly base metal alloys. To evaluate the mechanical properties such as tensile strength and surface roughness of the new and recast base metal (nickel-chromium) alloys. Recasting of the base metal alloys derived from sprue and button, to make it reusable has been done. A total of 200 test specimens were fabricated using specially fabricated jig of metal and divided into two groups- 100 specimens of new alloy and 100 specimens of recast alloys, which were tested for tensile strength on universal testing machine and surface roughness on surface roughness tester. Tensile strength of new alloy showed no statistically significant difference (p-value>0.05) from recast alloy whereas new alloy had statistically significant surface roughness (Maximum and Average surface roughness) difference (p-value<0.01) as compared to recast alloy. Within the limitations of the study it is concluded that the tensile strength will not be affected by recasting of nickel-chromium alloy whereas surface roughness increases markedly.

  4. Protective effects of a zinc-hydroxyapatite toothpaste on enamel erosion: SEM study

    PubMed Central

    Colombo, Marco; Beltrami, Riccardo; Rattalino, Davide; Mirando, Maria; Chiesa, Marco; Poggio, Claudio

    2016-01-01

    Summary Aim The aim of the present in vitro study was to evaluate the protective effects of a zinc-hydroxyapatite toothpaste against an erosive challenge produced by a soft drink (Coca-Cola) using Scanning Electron Microscopy (SEM). Methods Forty specimens were assigned to 4 groups of 10 specimens each (group 1: no erosive challenge, no toothpaste treatment, group 2: erosive challenge, no toothpaste treatment, group 3: erosive challenge, fluoride toothpaste treatment, group 4: erosive challenge, zinc-hydroxyapatite toothpaste treatment). The surface of each specimen was imaged by SEM. A visual rating system was used to evaluate the condition of the enamel surface; results were analyzed by nonparametric statistical methods. Results Statistically significant differences were found between the samples untreated and those immersed in Coca-Cola (group 1, 2); the highest grade of damage was found in group 2, while the lowest grade was recorded in the samples of group 4. Comparing the groups, the two analyzed toothpaste tended to protect in different extend. Conclusions In this study treatment of erosively challenged enamel with Zn-Hap toothpaste showed a clear protective effect. This was greater than the effect observed for a normal fluoride toothpaste and confirmed the potential benefit the Zn-HAP technology can provide in protecting enamel from erosive acid challenges. PMID:28149449

  5. Protective effects of a zinc-hydroxyapatite toothpaste on enamel erosion: SEM study.

    PubMed

    Colombo, Marco; Beltrami, Riccardo; Rattalino, Davide; Mirando, Maria; Chiesa, Marco; Poggio, Claudio

    2016-01-01

    The aim of the present in vitro study was to evaluate the protective effects of a zinc-hydroxyapatite toothpaste against an erosive challenge produced by a soft drink (Coca-Cola) using Scanning Electron Microscopy (SEM). Forty specimens were assigned to 4 groups of 10 specimens each (group 1: no erosive challenge, no toothpaste treatment, group 2: erosive challenge, no toothpaste treatment, group 3: erosive challenge, fluoride toothpaste treatment, group 4: erosive challenge, zinc-hydroxyapatite toothpaste treatment). The surface of each specimen was imaged by SEM. A visual rating system was used to evaluate the condition of the enamel surface; results were analyzed by nonparametric statistical methods. Statistically significant differences were found between the samples untreated and those immersed in Coca-Cola (group 1, 2); the highest grade of damage was found in group 2, while the lowest grade was recorded in the samples of group 4. Comparing the groups, the two analyzed toothpaste tended to protect in different extend. In this study treatment of erosively challenged enamel with Zn-Hap toothpaste showed a clear protective effect. This was greater than the effect observed for a normal fluoride toothpaste and confirmed the potential benefit the Zn-HAP technology can provide in protecting enamel from erosive acid challenges.

  6. Keratosis reduces sensitivity of anal cytology in detecting anal intraepithelial neoplasia.

    PubMed

    ElNaggar, Adam C; Santoso, Joseph T; Xie, Huiwen Bill

    2012-02-01

    To identify factors that may contribute to poor sensitivity of anal cytology in contrast to the sensitivity of anoscopy in heterosexual women. We analyzed 324 patients with biopsy confirmed diagnosis of genital intraepithelial neoplasia (either vulva, vaginal, or cervical) from 2006 to 2011 who underwent both anal cytology and anoscopy. Cytology, anoscopy, and biopsy results were recorded. Biopsy specimens underwent independent analysis for quality of specimen. Also, biopsy specimens were analyzed for characteristics that may contribute to correlation, or lack thereof, between anal cytology and anoscopic directed biopsy. 133 (41%) patients had abnormal anoscopy and underwent directed biopsy. 120 patients with normal anal cytology had anoscopy directed biopsies, resulting in 58 cases of AIN (sensitivity 9.4%; 0.039-0.199). This cohort was noted to have extensive keratosis covering the entire dysplastic anal lesion. 18 patients yielded abnormal anal cytology. Of these patients, 13 had anoscopic directed biopsies revealing 6 with AIN and absent keratosis (specificity 88.6%; 0.78-0.95). The κ statistic for anal cytology and anoscopy was -0.0213 (95% CI=-0.128-0.086). Keratosis reduces the sensitivity of anal cytology. Furthermore, anal cytology poorly correlates with anoscopy in the detection of AIN (κ statistic=-0.0213). Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Research on Statistical Methodology Applicable to Technical Problems Associated with Navy Programs.

    DTIC Science & Technology

    1987-10-01

    the fleetwide use of organotin antifouling paints that contain tributyltin ( TBT ), a tin-based compound, as a biocide. Organotin antifouling compounds...with this program has been devoted to providing technical and analytical support on various related statistical aspects. The TBT -release rate of a...paini ;q detrmined by placing a coated specimen panel or cylinder into a container of synthetic seawater, measuring the increasing concentration of TBT in

  8. [The bonding characteristic of titanium and RG experiment porcelain].

    PubMed

    Ren, Wei-hong; Guo, Tian-wen; Tian, Jie-mo; Zhang, Yun-long

    2003-07-01

    To study the bonding characteristic of Titanium and RG experiment porcelain. 5 specimens with a size of 10 mm x 5 mm x 1.4 mm were cast from pure titanium. Then 1 mm of RG experiment opaque and body porcelain were fused on the surface of the titanium specimens. The interface of titanium and porcelain was analyzed with a scanning electron microscope with energy-despersive spectrometry; 6 metal specimens with the size of 25 mm x 3 mm x 0.5 mm were cast from Ni-Cr alloy and a uniform thickness of 1 mm of VMK 99 porcelain was veneered on the central area of 8 mm x 3 mm 18 metal specimens as the same size were cast from pure titanium. The uniform thickness of 1 mm of VITA TITANKERAMIK porcelain, of Noritake super porcelain Ti-22 and of RG experiment porcelain were veneered on every 6 specimens respectively in the central area of 8 mm x 3 mm. The specimens were subjected to a three-point bending test on a load-test machine with a span of 20 mm, then the failure loads were recorded and statistically analysised. The RG porcelain/titanium crown was fabricated by fusing RG opaque porcelain and body porcelain to cast titanium substrate crown. The SEM results show no porosity and crackle were found in the interface. The energy-dispersive spectrometry show that there are Si, Ti and O in the 1 micro m layer between porcelain and titanium, which suggesting titanium and experiment porcelain bonding well. The three point test showed the fracture force for the combinations of titanium/VITA TITANKERAMIK porcelain, titanium/Noritake super porcelain Ti-22 and titanium/RG experiment porcelain were (7.233 +/- 2.539) N, (5.533 +/- 1.199) N and (6.316 +/- 1.433) N respectively. There were not statistically significant differences among them (t test, P < 0.01). The fracture force for the Ni-Cr alloy/VMK99 porcelain combination (12.733 +/- 3.297) N was significantly greater than those of the cast titanium/porcelain (t test, P > 0.05). The crown was translucent with no crack. RG porcelain is well compatible with titanium.

  9. Laser welding of a cobalt-chromium removable partial denture alloy.

    PubMed

    NaBadalung, D P; Nicholls, J I

    1998-03-01

    The electric alloy brazed joints of removable partial denture alloys have failed frequently after routine usage. A technique providing higher joint strengths was investigated. This investigation compared the tensile strengths of electric-brazed and laser-welded joints for a cobalt-chromium removable partial denture alloy. Twenty-four cobalt-chromium standard tensile testing rods were prepared and divided into three groups of eight. All specimens in the control group (group 1) were left in the as-cast condition. Groups 2 and 3 were the test specimens, which were sectioned at the center of the rod. Eight specimens were joined by using electric brazing, and the remaining specimens were joined by using laser welding. After joining, each joint was ground to a uniform diameter, then tested to tensile failure on an Instron universal testing machine. Failure loads were recorded and fracture stress calculated. Statistical analysis was applied. The student-Newman-Keuls test showed a highly significant difference between the joint strengths of the as-cast control specimens, the electric-brazed and laser-welded joints. The tensile strengths of the as-cast joints were higher than those for the laser-welded joints, and both were higher than the electric-brazed joint strengths.

  10. A New Integrated Approach to Taxonomy: The Fusion of Molecular and Morphological Systematics with Type Material in Benthic Foraminifera

    PubMed Central

    Roberts, Angela; Austin, William; Evans, Katharine; Bird, Clare; Schweizer, Magali; Darling, Kate

    2016-01-01

    A robust and consistent taxonomy underpins the use of fossil material in palaeoenvironmental research and long-term assessment of biodiversity. This study presents a new integrated taxonomic protocol for benthic foraminifera by unequivocally reconciling the traditional taxonomic name to a specific genetic type. To implement this protocol, a fragment of the small subunit ribosomal RNA (SSU rRNA) gene is used in combination with 16 quantitative morphometric variables to fully characterise the benthic foraminiferal species concept of Elphidium williamsoni Haynes, 1973. A combination of live contemporary topotypic specimens, original type specimens and specimens of genetic outliers were utilised in this study. Through a series of multivariate statistical tests we illustrate that genetically characterised topotype specimens are morphologically congruent with both the holotype and paratype specimens of E. williamsoni Haynes, 1973. We present the first clear link between morphologically characterised type material and the unique SSU rRNA genetic type of E. williamsoni. This example provides a standard framework for the benthic foraminifera which bridges the current discontinuity between molecular and morphological lines of evidence, allowing integration with the traditional Linnaean roots of nomenclature to offer a new prospect for taxonomic stability. PMID:27388271

  11. Reliability of the Xpert HPV assay to detect high-risk human papillomavirus DNA in a colposcopy referral population.

    PubMed

    Castle, Philip E; Smith, Katherine M; Davis, Thomas E; Schmeler, Kathleen M; Ferris, Daron G; Savage, Ashlyn H; Gray, Jermaine E; Stoler, Mark H; Wright, Thomas C; Ferenczy, Alex; Einstein, Mark H

    2015-01-01

    The Xpert HPV Assay (Xpert; Cepheid, Sunnyvale, CA) was developed for the multianalytic GeneXpert platform. In a colposcopy referral population of 708 women living in the United States, two cervical specimens, A and B, were collected, and both were tested by the Xpert assay for high-risk human papillomavirus (hrHPV) DNA, permitting an evaluation of its test reliability. Specimen B was also tested by Hybrid Capture 2 (hc2; Qiagen, Germantown, MD) and the cobas HPV Test (cobas; Roche Molecular Systems, Pleasanton, CA). The κ and percent agreement for any hrHPV for the two Xpert results were 0.88 and 94.5%, respectively. There was no statistical difference in testing positive on both specimens by Xpert (P = .62). The sensitivity for detection of cervical intraepithelial neoplasia grade 2 or more severe (CIN2+) was 89.0% using specimen A and 90.4% using specimen B for Xpert, 90.4% for cobas, and 81.6% for hc2. The Xpert assay was sensitive and reliable for the detection of hrHPV and the identification of women with CIN2+. Copyright© by the American Society for Clinical Pathology.

  12. Evaluation of specimen preservatives for DNA analyses of bees

    USGS Publications Warehouse

    Frampton, M.; Droege, S.; Conrad, T.; Prager, S.; Richards, M.H.

    2008-01-01

    Large-scale insect collecting efforts that are facilitated by the use of pan traps result in large numbers of specimens being collected. Storage of these specimens can be problematic if space and equipment are limited. In this study, we investigated the effects of various preservatives (alcohol solutions and DMSO) on the amount and quality of DNA extracted from bees (specifically Halictidae, Apidae, and Andrenidae). In addition, we examined the amount and quality of DNA obtained from bee specimens killed and stored at -80 degrees C and from specimens stored for up to 24 years in ethanol. DNA quality was measured in terms of how well it could be PCR-amplified using a set of mitochondrial primers that are commonly used in insect molecular systematics. Overall the best methods of preservation were ultra-cold freezing and dimethyl sulfoxide, but these are both expensive and in the case of ultra-cold freezing, somewhat impractical for field entomologists. Additionally, dimethyl sulfoxide was shown to have adverse effects on morphological characters that are typically used for identification to the level of species. We therefore recommend that the best alternative is 95% ethanol, as it preserves bee specimens well for both morphological and molecular studies.

  13. HAADF-STEM atom counting in atom probe tomography specimens: Towards quantitative correlative microscopy.

    PubMed

    Lefebvre, W; Hernandez-Maldonado, D; Moyon, F; Cuvilly, F; Vaudolon, C; Shinde, D; Vurpillot, F

    2015-12-01

    The geometry of atom probe tomography tips strongly differs from standard scanning transmission electron microscopy foils. Whereas the later are rather flat and thin (<20 nm), tips display a curved surface and a significantly larger thickness. As far as a correlative approach aims at analysing the same specimen by both techniques, it is mandatory to explore the limits and advantages imposed by the particular geometry of atom probe tomography specimens. Based on simulations (electron probe propagation and image simulations), the possibility to apply quantitative high angle annular dark field scanning transmission electron microscopy to of atom probe tomography specimens has been tested. The influence of electron probe convergence and the benefice of deconvolution of electron probe point spread function electron have been established. Atom counting in atom probe tomography specimens is for the first time reported in this present work. It is demonstrated that, based on single projections of high angle annular dark field imaging, significant quantitative information can be used as additional input for refining the data obtained by correlative analysis of the specimen in APT, therefore opening new perspectives in the field of atomic scale tomography. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Application of cryopreservation to genetic analyses of a photosynthetic picoeukaryote community.

    PubMed

    Kawachi, Masanobu; Kataoka, Takafumi; Sato, Mayumi; Noël, Mary-Hélène; Kuwata, Akira; Demura, Mikihide; Yamaguchi, Haruyo

    2016-02-01

    Cryopreservation is useful for long-term maintenance of living strains in microbial culture collections. We applied this technique to environmental specimens from two monitoring sites at Sendai Bay, Japan and compared the microbial diversity of photosynthetic picoeukaryotes in samples before and after cryopreservation. Flow cytometry (FCM) showed no considerable differences between specimens. We used 2500 cells sorted with FCM for next-generation sequencing of 18S rRNA gene amplicons and after removing low-quality sequences obtained 10,088-37,454 reads. Cluster analysis and comparative correlation analysis of observed high-level operational taxonomic units indicated similarity between specimens before and after cryopreservation. The effects of cryopreservation on cells were assessed with representative culture strains, including fragile cryptophyte cells. We confirmed the usefulness of cryopreservation for genetic studies on environmental specimens, and found that small changes in FCM cytograms after cryopreservation may affect biodiversity estimation. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Creep-rupture and fractographic analysis of candidate Stirling engine superalloys tested in air

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhattachryya, S.

    The creep-rupture behavior of six candidate Stirling engine iron-base superalloys was determined in air. The alloys tested included four wrought alloys (A-286, INCOLOY Alloy 800H, N-155, and 19-9DL) and two cast alloys (CRM-6D and XF-818). The wrought alloys were evaluated in the form of sheet; the cast alloy specimens were investment cast to shape. The creep-rupture specimens were tested in air for up to 3000 hours over the temperature range 650/sup 0/ to 925/sup 0/C. Microstructural and fractographic aspects of the ruptured specimens are discussed with a few correlational graphical analyses included for XF-818 and 19-9DL. Tests are continuing inmore » 15 MPa hydrogen, and later these data will be correlated with air data and microstructural analysis of the specimens conducted.« less

  16. Ultrastable gold substrates: Properties of a support for high-resolution electron cryomicroscopy of biological specimens

    PubMed Central

    Russo, Christopher J.; Passmore, Lori A.

    2016-01-01

    Electron cryomicroscopy (cryo-EM) allows structure determination of a wide range of biological molecules and specimens. All-gold supports improve cryo-EM images by reducing radiation-induced motion and image blurring. Here we compare the mechanical and electrical properties of all-gold supports to amorphous carbon foils. Gold supports are more conductive, and have suspended foils that are not compressed by differential contraction when cooled to liquid nitrogen temperatures. These measurements show how the choice of support material and geometry can reduce specimen movement by more than an order of magnitude during low-dose imaging. We provide methods for fabrication of all-gold supports and preparation of vitrified specimens. We also analyse illumination geometry for optimal collection of high resolution, low-dose data. Together, the support structures and methods herein can improve the resolution and quality of images from any electron cryomicroscope. PMID:26592474

  17. Robust Cytokine and Chemokine Response in Nasopharyngeal Secretions: Association With Decreased Severity in Children With Physician Diagnosed Bronchiolitis

    PubMed Central

    Nicholson, Erin G.; Schlegel, Chelsea; Garofalo, Roberto P.; Mehta, Reena; Scheffler, Margaret; Mei, Minghua; Piedra, Pedro A.

    2016-01-01

    Background. Bronchiolitis causes substantial disease in young children. Previous findings had indicated that a robust innate immune response was not associated with a poor clinical outcome in bronchiolitis. This study tested the hypothesis that increased concentrations of cytokines and chemokines in nasal wash specimens were associated with decreased severity in bronchiolitis. Methods. Children <24 months old who presented to the emergency department with signs and symptoms of bronchiolitis were eligible for enrollment. Nasal wash specimens were analyzed for viral pathogens and cytokine/chemokine concentrations. These results were evaluated with regard to disposition. Results. One hundred eleven children with bronchiolitis were enrolled. A viral pathogen was identified in 91.9% of patients (respiratory syncytial virus in 51.4%, human rhinovirus in 11.7%). Higher levels of cytokines and chemokines (interferon [IFN] γ; interleukin [IL] 4, 15, and 17; CXCL10; and eotaxin) were significantly associated with a decreased risk of hospitalization. IL-17, IL-4, IFN-γ, and IFN-γ–inducible protein 10 (CXCL10 or IP-10) remained statistically significant in the multivariate analyses. Conclusions. The cytokines and chemokines significantly associated with decreased bronchiolitis severity are classified in a wide range of functional groups (T-helper 1 and 2, regulatory, and chemoattractant). The involvement of these functional groups suggest that a broadly overlapping cytokine/chemokine response is required for control of virus-mediated respiratory disease in young children. PMID:27190183

  18. Clinical significance of nm23 gene expression in gastric cancer.

    PubMed

    Mönig, Stefan P; Nolden, Brit; Lübke, Thomas; Pohl, Alexandra; Grass, Guido; Schneider, Paul M; Dienes, Hans P; Hölscher, Arnulf H; Baldus, Stephan E

    2007-01-01

    The expression of the nm23 gene has been associated with the development of metastasis. Numerous studies have shown down-regulation of nm23 expression in metastatic breast and colon cancer. The expression of the putative metastasis-suppressor gene nm23 in gastric carcinoma is controversial. The aim of this study was the analysis of nm23 expression in a large series of gastric cancer patients. In a retrospective immunohistochemical study specimens obtained from 116 gastric cancer patients (mean age 64 years; range: 33-85) who had undergone gastrectomy with extended lymphadenectomy were analyzed. Nm23 expression in the tumor epithelium was studied by immunohistochemistry followed by a semi-quantitative (score 0-3) evaluation. Statistical analysis including Chi-square test, uni- and multivariate survival analyses were performed. The nm23 staining pattern was positive (score 2-3) in 100 (86.2%) specimens and negative (score 0-1) in 16 (13.8%) samples. Lymph node metastasis was found in 65% of the patients. No significant correlations could be determined between nm23 expression and other variables such as gender, age, tumor differentiation, WHO-, Laurén-, Goseki-, or Ming-classification. The intensity of nm23 staining in the tumor cells was not significantly correlated with depth of tumor infiltration (T-stage), lymph node metastasis (N-stage), distant metastasis (M-stage), UICC-stage, or prognosis. Our series did not show a correlation of nm23 expression in terms of lymph node and distant metastasis or prognosis in gastric cancer patients.

  19. Characterization of the Skin Microbiota in Italian Stream Frogs (Rana italica) Infected and Uninfected by a Cutaneous Parasitic Disease

    PubMed Central

    Federici, Ermanno; Rossi, Roberta; Fidati, Laura; Paracucchi, Romina; Scargetta, Silvia; Montalbani, Elena; Franzetti, Andrea; La Porta, Gianandrea; Fagotti, Anna; Simonceli, Francesca; Cenci, Giovanni; Di Rosa, Ines

    2015-01-01

    In human and wildlife populations, the natural microbiota plays an important role in health maintenance and the prevention of emerging infectious diseases. In amphibians, infectious diseases have been closely associated with population decline and extinction worldwide. Skin symbiont communities have been suggested as one of the factors driving the different susceptibilities of amphibians to diseases. The activity of the skin microbiota of amphibians against fungal pathogens, such as Batrachochytrium dendrobatidis, has been examined extensively, whereas its protective role towards the cutaneous infectious diseases caused by Amphibiocystidium parasites has not yet been elucidated in detail. In the present study, we investigated, for the first time, the cutaneous microbiota of the Italian stream frog (Rana italica) and characterized the microbial assemblages of frogs uninfected and infected by Amphibiocystidium using the Illumina next-generation sequencing of 16S rRNA gene fragments. A total of 629 different OTUs belonging to 16 different phyla were detected. Bacterial populations shared by all individuals represented only one fifth of all OTUs and were dominated by a small number of OTUs. Statistical analyses based on Bray-Curtis distances showed that uninfected and infected specimens had distinct cutaneous bacterial community structures. Phylotypes belonging to the genera Janthinobacterium, Pseudomonas, and Flavobacterium were more abundant, and sometimes almost exclusively present, in uninfected than in infected specimens. These bacterial populations, known to exhibit antifungal activity in amphibians, may also play a role in protection against cutaneous infectious diseases caused by Amphibiocystidium parasites. PMID:26370166

  20. Influence of nanometer scale particulate fillers on some properties of microfilled composite resin.

    PubMed

    Garoushi, Sufyan; Lassila, Lippo V J; Vallittu, Pekka K

    2011-07-01

    The aim of this study was to evaluate the effect of different weight fractions of nanometer sized particulate filler on properties of microfilled composite resin. Composite resin was prepared by mixing 33 wt% of resin matrix to the 67 wt% of silane treated microfine silica particulate fillers with various fractions of nanometer sized fillers (0, 10, 15, 20, 30 wt%) using a high speed mixing machine. Test specimens made of the composites were tested with a three-point bending test with a speed of 1.0 mm/min until fracture. Surface microhardess (Vicker's microhardness) was also determined. The volumetric shrinkage in percent was calculated as a buoyancy change in distilled water by means of the Archimedes principle. The degree of monomer conversion (DC%) of the experimental composites containing different nanofiller fractions was measured using FTIR spectroscopy. Surface roughness (Ra) was determined using a surface profilometer. Nanowear measurements were carried out using a nanoindentation device. The water uptake of specimens was also measured. Parameters were statistically analysed by ANOVA (P < 0.05). The group without nanofillers showed the highest flexural strength and modulus, DC% and Ra value. The group with 30% nanofillers had the highest water uptake and volumetric shrinkage. No significant difference was found in Vicker's microhardness and the nanowear of the composites. The plain microfilled composite demonstrated superior properties compared to the composites loaded with nanofillers with the exception of surface roughness.

  1. Proteomic characterization of paired non-malignant and malignant African-American prostate epithelial cell lines distinguishes them by structural proteins.

    PubMed

    Myers, Jennifer S; Vallega, Karin A; White, Jason; Yu, Kaixian; Yates, Clayton C; Sang, Qing-Xiang Amy

    2017-07-11

    While many factors may contribute to the higher prostate cancer incidence and mortality experienced by African-American men compared to their counterparts, the contribution of tumor biology is underexplored due to inadequate availability of African-American patient-derived cell lines and specimens. Here, we characterize the proteomes of non-malignant RC-77 N/E and malignant RC-77 T/E prostate epithelial cell lines previously established from prostate specimens from the same African-American patient with early stage primary prostate cancer. In this comparative proteomic analysis of RC-77 N/E and RC-77 T/E cells, differentially expressed proteins were identified and analyzed for overrepresentation of PANTHER protein classes, Gene Ontology annotations, and pathways. The enrichment of gene sets and pathway significance were assessed using Gene Set Enrichment Analysis and Signaling Pathway Impact Analysis, respectively. The gene and protein expression data of age- and stage-matched prostate cancer specimens from The Cancer Genome Atlas were analyzed. Structural and cytoskeletal proteins were differentially expressed and statistically overrepresented between RC-77 N/E and RC-77 T/E cells. Beta-catenin, alpha-actinin-1, and filamin-A were upregulated in the tumorigenic RC-77 T/E cells, while integrin beta-1, integrin alpha-6, caveolin-1, laminin subunit gamma-2, and CD44 antigen were downregulated. The increased protein level of beta-catenin and the reduction of caveolin-1 protein level in the tumorigenic RC-77 T/E cells mirrored the upregulation of beta-catenin mRNA and downregulation of caveolin-1 mRNA in African-American prostate cancer specimens compared to non-malignant controls. After subtracting race-specific non-malignant RNA expression, beta-catenin and caveolin-1 mRNA expression levels were higher in African-American prostate cancer specimens than in Caucasian-American specimens. The "ECM-Receptor Interaction" and "Cell Adhesion Molecules", and the "Tight Junction" and "Adherens Junction" pathways contained proteins are associated with RC-77 N/E and RC-77 T/E cells, respectively. Our results suggest RC-77 T/E and RC-77 N/E cell lines can be distinguished by differentially expressed structural and cytoskeletal proteins, which appeared in several pathways across multiple analyses. Our results indicate that the expression of beta-catenin and caveolin-1 may be prostate cancer- and race-specific. Although the RC-77 cell model may not be representative of all African-American prostate cancer due to tumor heterogeneity, it is a unique resource for studying prostate cancer initiation and progression.

  2. Influence of investment, disinfection, and storage on the microhardness of ocular resins.

    PubMed

    Goiato, Marcelo Coelho; dos Santos, Daniela Micheline; Gennari-Filho, Humberto; Zavanelli, Adriana Cristina; Dekon, Stefan Fiuza de Carvalho; Mancuso, Daniela Nardi

    2009-01-01

    The longevity of an ocular prosthesis is directly related to the resistance to erosion of its material. The purpose of this study was to evaluate the effects of chemical disinfection and the method of investment on the microhardness of ocular prosthesis acrylic resin. Thirty-two test specimen investments were obtained in two silicones. A segment was cut in each test specimen, and each specimen was fixed in an acrylic disk. The specimens were then polished and submitted to the first microhardness test before immersion in distilled water and incubation for 2 months. During this 2-month period, the specimens were immersed in a water bath at 37 degrees C and were disinfected daily; half were disinfected with neutral soap and the other half were disinfected with 4% chlorhexidine gluconate. After the storage phase and disinfection, a second microhardness test was performed. The surface microhardness values for the acrylic resins were submitted to ANOVA, followed by the Tukey test. The disinfection and the period of storage did not statistically influence the surface microhardness of the acrylic resin, independent of the method of investment of the specimens (Zetalabor or Vipi Sil). The investment of specimens with Zetalabor silicone presented a greater surface hardness, independent of the type of disinfection and the period of storage. Based on these results, we suggest that the microhardness of the resin evaluated was not influenced by the method of disinfection or the time of storage used and was affected only by the investment material.

  3. Residual oxygen releasing time from dental structure after carbamide peroxide exposure: study of the effects of a neutralizer gel.

    PubMed

    Salome, Paloma; Bueno, Renata Pla Rizzolo; Nascimento, Paulo Cicero; Pozzobon, Roselaine Terezinha

    2012-01-01

    The purpose of this article was to assess in vitro the effects of a catalase-based neutralizer gel in the release of residual oxygen in permanent human teeth specimens exposed to 10% carbamide peroxide. Thirty teeth specimens (5.0 x 5.0 x 3.0 mm3) were randomly divided into three groups (n = 10): Group 1, nonbleached negative control specimens; Group 2, bleached positive control specimens; and Group 3, bleached specimens exposed to a catalase-based gel. The bleaching treatment was performed six hours per day for 14 days. At the end of the bleaching treatment, Group 3 specimens were immersed in a receptacle containing the catalase-based experimental gel for three minutes. Titrations were performed to determine the quantity of residual oxygen that each test specimen released, starting immediately after the end of the bleaching treatment and exposure (or not) to the catalase-based gel, and repeated on days 1-5, 10, and 15. The values obtained were statistically analyzed by ANOVA and a Tukey post hoc test (P < 0.05). The release values of residual O2 for Group 2 were equal to those of Group 1 after 10 days and to those of Group 3 after five days. The use of a catalase-based experimental neutralizer gel, applied for three minutes, reduced by half the time required for complete release of residual oxygen from tooth structure after exposure to a 10% carbamide peroxide bleaching agent.

  4. Development of Statistical Process Control Methodology for an Environmentally Compliant Surface Cleaning Process in a Bonding Laboratory

    NASA Technical Reports Server (NTRS)

    Hutchens, Dale E.; Doan, Patrick A.; Boothe, Richard E.

    1997-01-01

    Bonding labs at both MSFC and the northern Utah production plant prepare bond test specimens which simulate or witness the production of NASA's Reusable Solid Rocket Motor (RSRM). The current process for preparing the bonding surfaces employs 1,1,1-trichloroethane vapor degreasing, which simulates the current RSRM process. Government regulations (e.g., the 1990 Amendments to the Clean Air Act) have mandated a production phase-out of a number of ozone depleting compounds (ODC) including 1,1,1-trichloroethane. In order to comply with these regulations, the RSRM Program is qualifying a spray-in-air (SIA) precision cleaning process using Brulin 1990, an aqueous blend of surfactants. Accordingly, surface preparation prior to bonding process simulation test specimens must reflect the new production cleaning process. The Bonding Lab Statistical Process Control (SPC) program monitors the progress of the lab and its capabilities, as well as certifies the bonding technicians, by periodically preparing D6AC steel tensile adhesion panels with EA-91 3NA epoxy adhesive using a standardized process. SPC methods are then used to ensure the process is statistically in control, thus producing reliable data for bonding studies, and identify any problems which might develop. Since the specimen cleaning process is being changed, new SPC limits must be established. This report summarizes side-by-side testing of D6AC steel tensile adhesion witness panels and tapered double cantilevered beams (TDCBs) using both the current baseline vapor degreasing process and a lab-scale spray-in-air process. A Proceco 26 inches Typhoon dishwasher cleaned both tensile adhesion witness panels and TDCBs in a process which simulates the new production process. The tests were performed six times during 1995, subsequent statistical analysis of the data established new upper control limits (UCL) and lower control limits (LCL). The data also demonstrated that the new process was equivalent to the vapor degreasing process.

  5. Species delimitation in plants using the Qinghai–Tibet Plateau endemic Orinus (Poaceae: Tridentinae) as an example

    PubMed Central

    Su, Xu; Wu, Guili; Li, Lili; Liu, Jianquan

    2015-01-01

    Background and Aims Accurate identification of species is essential for the majority of biological studies. However, defining species objectively and consistently remains a challenge, especially for plants distributed in remote regions where there is often a lack of sufficient previous specimens. In this study, multiple approaches and lines of evidence were used to determine species boundaries for plants occurring in the Qinghai–Tibet Plateau, using the genus Orinus (Poaceae) as a model system for an integrative approach to delimiting species. Methods A total of 786 individuals from 102 populations of six previously recognized species were collected for niche, morphological and genetic analyses. Three plastid DNA regions (matK, rbcL and trnH-psbA) and one nuclear DNA region [internal transcribed space (ITS)] were sequenced. Key Results Whereas six species had been previously recognized, statistical analyses based on character variation, molecular data and niche differentiation identified only two well-delimited clusters, together with a third possibly originating from relatively recent hybridization between, or historical introgression from, the other two. Conclusions Based on a principle of integrative species delimitation to reconcile different sources of data, the results provide compelling evidence that the six previously recognized species of the genus Orinus that were examined should be reduced to two, with new circumscriptions, and a third, identified in this study, should be described as a new species. This empirical study highlights the value of applying genetic differentiation, morphometric statistics and ecological niche modelling in an integrative approach to re-circumscribing species boundaries. The results produce relatively objective, operational and unbiased taxonomic classifications of plants occurring in remote regions. PMID:25987712

  6. Geographic variation of stable isotopes in African elephant ivory

    NASA Astrophysics Data System (ADS)

    Ziegler, S.; Merker, S.; Jacob, D.

    2012-04-01

    In 1989, the international community listed the African elephant in Appendix I of the Convention on International Trade in Endangered Species of Wild Fauna and Flora (CITES) thus prohibiting commercial ivory trade. Recent surveillance data show that the illegal trade in ivory has been growing worldwide. Long-term preservation of many of the African elephant populations can be supported with a control mechanism that helps with the implementation of remedial conservation action. Therefore, setting up a reference database that predicts the origin of ivory specimens can assist in determining smuggling routes and the provenance of illegal ivory. Our research builds on earlier work to seek an appropriate method for determining the area of origin for individual tusks. Several researchers have shown that the provenance of elephant ivory can be traced by its isotopic composition, but this is the first attempt to produce an integrated isotopic reference database of elephant ivory provenance. We applied a combination of various routine geochemical analyses to measure the stable isotope ratios of hydrogen, carbon, nitrogen, oxygen, and sulphur. Up to now, we analysed 606 ivory samples of known geographical origin from African range states, museums and private collections, comprising 22 African elephant range states. The isotopic measurements were superimposed with data layers from vegetation, geology and climate. A regression function for the isotope composition of the water isotopes in precipitation and collagen in ivory was developed to overcome the problem of imprecise origin of some of the sampled material. Multivariate statistics, such as nearest neighborhood and discriminate analysis were applied to eventually allow a statistical determination of the provenance for ivory of unknown origin. Our results suggest that the combination of isotopic parameters have the potential to provide predictable and complementary markers for estimating the origin of seized elephant ivory.

  7. Species delimitation in plants using the Qinghai-Tibet Plateau endemic Orinus (Poaceae: Tridentinae) as an example.

    PubMed

    Su, Xu; Wu, Guili; Li, Lili; Liu, Jianquan

    2015-07-01

    Accurate identification of species is essential for the majority of biological studies. However, defining species objectively and consistently remains a challenge, especially for plants distributed in remote regions where there is often a lack of sufficient previous specimens. In this study, multiple approaches and lines of evidence were used to determine species boundaries for plants occurring in the Qinghai-Tibet Plateau, using the genus Orinus (Poaceae) as a model system for an integrative approach to delimiting species. A total of 786 individuals from 102 populations of six previously recognized species were collected for niche, morphological and genetic analyses. Three plastid DNA regions (matK, rbcL and trnH-psbA) and one nuclear DNA region [internal transcribed space (ITS)] were sequenced. Whereas six species had been previously recognized, statistical analyses based on character variation, molecular data and niche differentiation identified only two well-delimited clusters, together with a third possibly originating from relatively recent hybridization between, or historical introgression from, the other two. Based on a principle of integrative species delimitation to reconcile different sources of data, the results provide compelling evidence that the six previously recognized species of the genus Orinus that were examined should be reduced to two, with new circumscriptions, and a third, identified in this study, should be described as a new species. This empirical study highlights the value of applying genetic differentiation, morphometric statistics and ecological niche modelling in an integrative approach to re-circumscribing species boundaries. The results produce relatively objective, operational and unbiased taxonomic classifications of plants occurring in remote regions. © The Author 2015. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Analysis of Ninety Degree Flexure Tests for Characterization of Composite Transverse Tensile Strength

    NASA Technical Reports Server (NTRS)

    OBrien, T. Kevin; Krueger, Ronald

    2001-01-01

    Finite element (FE) analysis was performed on 3-point and 4-point bending test configurations of ninety degree oriented glass-epoxy and graphite-epoxy composite beams to identify deviations from beam theory predictions. Both linear and geometric non-linear analyses were performed using the ABAQUS finite element code. The 3-point and 4-point bending specimens were first modeled with two-dimensional elements. Three-dimensional finite element models were then performed for selected 4-point bending configurations to study the stress distribution across the width of the specimens and compare the results to the stresses computed from two-dimensional plane strain and plane stress analyses and the stresses from beam theory. Stresses for all configurations were analyzed at load levels corresponding to the measured transverse tensile strength of the material.

  9. Assessment of Static Delamination Propagation Capabilities in Commercial Finite Element Codes Using Benchmark Analysis

    NASA Technical Reports Server (NTRS)

    Orifici, Adrian C.; Krueger, Ronald

    2010-01-01

    With capabilities for simulating delamination growth in composite materials becoming available, the need for benchmarking and assessing these capabilities is critical. In this study, benchmark analyses were performed to assess the delamination propagation simulation capabilities of the VCCT implementations in Marc TM and MD NastranTM. Benchmark delamination growth results for Double Cantilever Beam, Single Leg Bending and End Notched Flexure specimens were generated using a numerical approach. This numerical approach was developed previously, and involves comparing results from a series of analyses at different delamination lengths to a single analysis with automatic crack propagation. Specimens were analyzed with three-dimensional and two-dimensional models, and compared with previous analyses using Abaqus . The results demonstrated that the VCCT implementation in Marc TM and MD Nastran(TradeMark) was capable of accurately replicating the benchmark delamination growth results and that the use of the numerical benchmarks offers advantages over benchmarking using experimental and analytical results.

  10. Contributions to the knowledge of hard ticks (Acari: Ixodidae) in Colombia.

    PubMed

    Rivera-Páez, Fredy A; Labruna, Marcelo B; Martins, Thiago F; Perez, Jorge E; Castaño-Villa, Gabriel J; Ossa-López, Paula A; Gil, Carlos A; Sampieri, Bruno Rodrigues; Aricapa-Giraldo, Hector J; Camargo-Mathias, Maria I

    2018-01-01

    The known tick fauna of Colombia includes 58 species (15 Argasidae and 43 Ixodidae). To add to the knowledge of the biology of ticks in Colombia, hard ticks (Ixodidae) were collected from domestic animals or vegetation during 2014-2016 in 10 of Colombia's Departments. Ticks were identified to species through morphological examinations. Taxonomic identification was confirmed for some specimens by molecular methods, including phylogenetic analyses inferred from three tick genes (cytochrome c oxidase, 16S rDNA, second internal transcribed spacer). A total of 1745 tick specimens encompassing 8 species were collected. Overall, 5 tick species were recorded on cattle [Amblyomma dissimile, Amblyomma mixtum, Dermacentor nitens, Rhipicephalus microplus, Rhipicephalus sanguineus sensu lato (s.l.)], 5 on dogs (Amblyomma maculatum, Amblyomma ovale, Amblyomma varium, R. microplus, R. sanguineus s.l.), 3 on horses (A. mixtum, D. nitens, R. sanguineus s.l.), 3 on donkeys (A. mixtum, D. nitens, R. microplus), 1 on pig (D. nitens), and 2 from vegetation (A. mixtum, A. dissimile). This included the first records of A. mixtum from two Colombian Departments, indicating that the distribution of this tick in Colombia may be broader than currently known. Phylogenetic analyses confirmed that R. sanguineus s.l. specimens from 8 Departments belong to the "tropical species". Moreover, Colombian specimens of A. maculatum formed a large clade with GenBank sequences of A. maculatum and A. triste, although some Colombian specimens grouped with A. maculatum from the United States while others grouped with A. triste from Brazil. Significant polymorphisms were observed between specimens of A. ovale or D. nitens; for the former species, it is noteworthy that two distinct clades were observed. Our study provides new records for 8 tick species parasitizing domestic animals in Colombia, including species with veterinary and medical importance in the Neotropical region, such as R. microplus, R. sanguineus, D. nitens, A. mixtum, and A. maculatum. Noteworthy, we provide the first record of A. varium infesting a domestic mammal. Copyright © 2017 Elsevier GmbH. All rights reserved.

  11. Comparison of Macroscopic Pathology Measurements With Magnetic Resonance Imaging and Assessment of Microscopic Pathology Extension for Colorectal Liver Metastases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendez Romero, Alejandra, E-mail: a.mendezromero@erasmusmc.nl; Verheij, Joanne; Dwarkasing, Roy S.

    2012-01-01

    Purpose: To compare pathology macroscopic tumor dimensions with magnetic resonance imaging (MRI) measurements and to establish the microscopic tumor extension of colorectal liver metastases. Methods and Materials: In a prospective pilot study we included patients with colorectal liver metastases planned for surgery and eligible for MRI. A liver MRI was performed within 48 hours before surgery. Directly after surgery, an MRI of the specimen was acquired to measure the degree of tumor shrinkage. The specimen was fixed in formalin for 48 hours, and another MRI was performed to assess the specimen/tumor shrinkage. All MRI sequences were imported into our radiotherapymore » treatment planning system, where the tumor and the specimen were delineated. For the macroscopic pathology analyses, photographs of the sliced specimens were used to delineate and reconstruct the tumor and the specimen volumes. Microscopic pathology analyses were conducted to assess the infiltration depth of tumor cell nests. Results: Between February 2009 and January 2010 we included 13 patients for analysis with 21 colorectal liver metastases. Specimen and tumor shrinkage after resection and fixation was negligible. The best tumor volume correlations between MRI and pathology were found for T1-weighted (w) echo gradient sequence (r{sub s} = 0.99, slope = 1.06), and the T2-w fast spin echo (FSE) single-shot sequence (r{sub s} = 0.99, slope = 1.08), followed by the T2-w FSE fat saturation sequence (r{sub s} = 0.99, slope = 1.23), and the T1-w gadolinium-enhanced sequence (r{sub s} = 0.98, slope = 1.24). We observed 39 tumor cell nests beyond the tumor border in 12 metastases. Microscopic extension was found between 0.2 and 10 mm from the main tumor, with 90% of the cases within 6 mm. Conclusions: MRI tumor dimensions showed a good agreement with the macroscopic pathology suggesting that MRI can be used for accurate tumor delineation. However, microscopic extensions found beyond the tumor border indicate that caution is needed in selecting appropriate tumor margins.« less

  12. Extended analysis of Skylab experiment M558 data

    NASA Technical Reports Server (NTRS)

    Ukanwa, A. O.

    1976-01-01

    A careful review of the data from Skylab M558 was made in an effort to explain the apparent anomaly of the existence of radial concentration gradients whereas none should bave been observed. The very close modelling of the experimental axial concentration profiles by the unsteady-state one-dimensional solution of Fick's Law of self-diffusion in liquid zinc, and the condition of initial uniform concentration in the radioactive pellet portion of the experimental specimens would have precluded the appearance of such radial concentration gradients. Statistical analyses were used to test the significance of the observed deviation from radial-concentration homogeneity. A student t-distribution test of significance showed that, at 90% or even at 80% level of significance, there were no significant deviations from uniformity in radial concentrations. It was also concluded that the two likely causes of any deviation that existed were the zinc to zinc-65 bonding procedure and surface phenomena such as surface tension and capillary action.

  13. Marginal and Internal Discrepancies of Posterior Zirconia-Based Crowns Fabricated with Three Different CAD/CAM Systems Versus Metal-Ceramic.

    PubMed

    Ortega, Rocio; Gonzalo, Esther; Gomez-Polo, Miguel; Suárez, María J

    2015-01-01

    The aim of this study was to analyze the marginal and internal fit of metalceramic and zirconia-based crowns. Forty standardized steel specimens were prepared to receive posterior crowns and randomly divided into four groups (n = 10): (1) metal-ceramic, (2) NobelProcera Zirconia, (3) Lava Zirconia, and (4) VITA In-Ceram YZ. All crowns were cemented with glass-ionomer agent and sectioned buccolingually. A scanning electron microscope was used for measurements. Kruskal-Wallis and Wilcoxon signed rank test (α = .05) statistical analyses were conducted. Significant differences (P < .0001) in marginal discrepancies were observed between metal-ceramic and zirconia groups. No differences were found for the axial wall fit (P = .057). Significant differences were shown among the groups in discrepancies at the occlusal cusp (P = .0012) and at the fossa (P = .0062). No differences were observed between surfaces. All zirconia groups showed better values of marginal discrepancies than the metal-ceramic group. Procera Zirconia showed the lowest gaps.

  14. Effect of soldering on the metal-ceramic bond strength of an Ni-Cr base alloy.

    PubMed

    Nikellis, Ioannis; Levi, Anna; Zinelis, Spiros

    2005-11-01

    Although soldering is a common laboratory procedure, the use of soldering alloys may adversely affect metal-ceramic bond strength and potentially decrease the longevity of metal-ceramic restorations. The purpose of this study was to investigate the effect of soldering on metal-ceramic bond strength of a representative Ni-Cr base metal alloy. Twenty-eight rectangular (25 x 3 x 0.5 mm) Ni-based alloy (Wiron 99) specimens were equally divided into soldering (S) and reference (R) groups. Soldering group specimens were covered with a 0.1-mm layer of the appropriate solder (Wiron-Lot) and reduced by 0.1 mm on the opposite side. Five specimens of each group were used for the measurement of surface roughness parameter (R(z)) and hardness, and 3 were used for measurement of the modulus of elasticity. Six specimens of each group were covered with porcelain (Ceramco 3) and subjected to a 3-point bending test for evaluation of the metal-ceramic bond strength according to the ISO 9693 specification. The data from surface roughness, hardness, modulus of elasticity, and metal-ceramic bond strength were analyzed statistically, using independent t tests (alpha=.05). Statistical analysis of the R(z) surface roughness parameter (S: 3.4 +/- 0.3 mum; R: 3.7 +/- 0.7 microm; P=.07) and bond strength (S: 46 +/- 3 MPa; R: 40 +/- 5 MPa; P=.057) failed to reveal any significant difference between the 2 groups. The specimens of the soldering group demonstrated significantly lower values both in hardness (S: 128 +/- 11 VHN; R: 217 +/- 4 VHN; P<.001) and in modulus of elasticity (S: 135 +/- 4 GPa; R: 183 +/- 6 GPa; P=.035) than the reference group. Under the conditions of the present study, the addition of solder to the base metal alloy did not affect the metal-ceramic bond strength.

  15. Apparent Interfacial Fracture Toughness of Resin/Ceramic Systems

    PubMed Central

    Della Bona, A.; Anusavice, K.J.; Mecholsky, J.J.

    2008-01-01

    We suggest that the apparent interfacial fracture toughness (KA) may be estimated by fracture mechanics and fractography. This study tested the hypothesis that the KA of the adhesion zone of resin/ceramic systems is affected by the ceramic microstructure. Lithia disilicate-based (Empress2-E2) and leucite-based (Empress-E1) ceramics were surface-treated with hydrofluoric acid (HF) and/or silane (S), followed by an adhesive resin. Microtensile test specimens (n = 30; area of 1 ± 0.01 mm2) were indented (9.8 N) at the interface and loaded to failure in tension. We used tensile strength (σ) and the critical crack size (c) to calculate KA (KA = Yσc1/2) (Y = 1.65). ANOVA and Weibull analyses were used for statistical analyses. Mean KA (MPa•m1/2) values were: (E1HF) 0.26 ± 0.06; (E1S) 0.23 ± 0.06; (E1HFS) 0.30 ± 0.06; (E2HF) 0.31 ± 0.06; (E2S) 0.13 ± 0.05; and (E2HFS) 0.41 ± 0.07. All fractures originated from indentation sites. Estimation of interfacial toughness was feasible by fracture mechanics and fractography. The KA for the systems tested was affected by the ceramic microstructure and surface treatment. PMID:17062746

  16. CEQer: A Graphical Tool for Copy Number and Allelic Imbalance Detection from Whole-Exome Sequencing Data

    PubMed Central

    Piazza, Rocco; Magistroni, Vera; Pirola, Alessandra; Redaelli, Sara; Spinelli, Roberta; Redaelli, Serena; Galbiati, Marta; Valletta, Simona; Giudici, Giovanni; Cazzaniga, Giovanni; Gambacorti-Passerini, Carlo

    2013-01-01

    Copy number alterations (CNA) are common events occurring in leukaemias and solid tumors. Comparative Genome Hybridization (CGH) is actually the gold standard technique to analyze CNAs; however, CGH analysis requires dedicated instruments and is able to perform only low resolution Loss of Heterozygosity (LOH) analyses. Here we present CEQer (Comparative Exome Quantification analyzer), a new graphical, event-driven tool for CNA/allelic-imbalance (AI) coupled analysis of exome sequencing data. By using case-control matched exome data, CEQer performs a comparative digital exonic quantification to generate CNA data and couples this information with exome-wide LOH and allelic imbalance detection. This data is used to build mixed statistical/heuristic models allowing the identification of CNA/AI events. To test our tool, we initially used in silico generated data, then we performed whole-exome sequencing from 20 leukemic specimens and corresponding matched controls and we analyzed the results using CEQer. Taken globally, these analyses showed that the combined use of comparative digital exon quantification and LOH/AI allows generating very accurate CNA data. Therefore, we propose CEQer as an efficient, robust and user-friendly graphical tool for the identification of CNA/AI in the context of whole-exome sequencing data. PMID:24124457

  17. Effect of Intracoronal Depth of Teeth Restored with Endocrowns on Fracture Resistance: In Vitro and 3-dimensional Finite Element Analysis.

    PubMed

    Dartora, Nereu Roque; de Conto Ferreira, Michele Bertoluzi; Moris, Izabela Cristina Maurício; Brazão, Elisabeth Helena; Spazin, Aloísio Oro; Sousa-Neto, Manoel Damião; Silva-Sousa, Yara Terezinha; Gomes, Erica Alves

    2018-07-01

    Endodontically treated teeth have an increased risk of biomechanical failure because of significant loss of tooth structure. The biomechanical behavior of endodontically treated teeth restored was evaluated using different extensions of endocrowns inside the pulp chamber by in vitro and 3-dimensional finite element analysis (FEA). Thirty mandibular human molars were endodontically treated. Standardized endocrown preparations were performed, and the teeth were randomly divided into 3 groups (n = 10) according to different endocrown extensions inside the pulp chamber: G-5 mm, a 5-mm extension; G-3 mm, a 3-mm extension; and G-1 mm, a 1-mm extension. After adhesive cementation, all specimens were subjected to thermocycling and dynamic loading. The survival specimens were subjected to fracture resistance testing at a crosshead speed of 1 mm/min in a universal testing machine. All fractured specimens were subjected to fractography. Data were analyzed by 1-way analysis of variance and the Tukey post hoc test (P < .05). Stress distribution patterns in each group were analyzed using FEA. Qualitative analyses were performed according to the von Mises criterion. After dynamic loading, a survival rate of 100% was observed in all groups. For static loading, statistically significant differences among the groups were observed (P < .05) (G-5 mm = 2008.61 N, G-3 mm = 1795.41 N, and G-1 mm = 1268.12 N). Fractography showed a higher frequency of compression curls for G-5 mm and G-3 mm than for G-1 mm. FEA explained the results of fracture strength testing and fractography. Greater extension of endocrowns inside the pulp chamber provided better mechanical performance. Copyright © 2018 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  18. Biaxial flexure strength determination of endodontically accessed ceramic restorations.

    PubMed

    Kelly, R D; Fleming, G J P; Hooi, P; Palin, W M; Addison, O

    2014-08-01

    To report analytic solutions capable of identifying failure stresses from the biaxial flexure testing of geometries representative of endodontic access cavities prepared through dental restorative materials. The ring-on-ring biaxial flexure strength of annular discs with a central circular hole supported peripherally by a knife-edge support and loaded evenly at the upper edge of the central hole were solved using general expressions of deformations, moments and shears for flat plates of a constant thickness. To validate the solutions, finite element analyses were performed. A three-dimensional one-quarter model of the test was generated using a linear P-code FEA software and the boundary conditions represented the experimental test configuration whereby symmetry planes defined the full model. To enable comparison of the maximum principal stresses with experimental derived data, three groups of nominally identical feldspathic ceramic disks (n=30) were fabricated. Specimens from Group A received a 4mm diameter representative endodontic access cavity and were tested in ring-on-ring. Group B and C specimens remained intact and were tested in ring-on-ring and ball-on-ring, respectively, to give insight into strength scaling effects. Fractography was used to confirm failure origins, and statistical analysis of fracture strength data was performed using one-way ANOVAs (P<0.05) and a Weibull approach. The developed analytical solutions were demonstrated to deviate <1% from the finite element prediction in the configuration studied. Fractography confirmed the failure origin of tested samples to coincide with the predicted stress maxima and the area where fracture is observed to originate clinically. Specimens from the three experimental groups A-C exhibited different strengths which correlated with the volume scaling effects on measured strength. The solutions provided will enable geometric and materials variables to be systematically studied and remove the need for load-to-failure 'crunch the crown' testing. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  19. N-Acetyl-S-(n-Propyl)-L-Cysteine in Urine from Workers Exposed to 1-Bromopropane in Foam Cushion Spray Adhesives

    PubMed Central

    Hanley, Kevin W.; Petersen, Martin R.; Cheever, Kenneth L.; Luo, Lian

    2009-01-01

    1-Bromopropane (1-BP) has been marketed as an alternative for ozone depleting and other solvents; it is used in aerosol products, adhesives, metal, precision, and electronics cleaning solvents. Mechanisms of toxicity of 1-BP are not fully understood, but it may be a neurological and reproductive toxicant. Sparse exposure information prompted this study using 1-BP air sampling and urinary metabolites. Mercapturic acid conjugates are excreted in urine from 1-BP metabolism involving debromination. Research objectives were to evaluate the utility of urinary N-acetyl-S-(n-propyl)-L-cysteine (AcPrCys) for assessing exposure to 1-BP and compare it to urinary bromide [Br(−)] previously reported for these workers. Forty-eight-hour urine specimens were obtained from 30 workers at two factories where 1-BP spray adhesives were used to construct polyurethane foam seat cushions. Urine specimens were also obtained from 21 unexposed control subjects. All the workers' urine was collected into composite samples representing three time intervals: at work, after work but before bedtime, and upon awakening. Time-weighted average (TWA) geometric mean breathing zone concentrations were 92.4 and 10.5 p.p.m. for spraying and non-spraying jobs, respectively. Urinary AcPrCys showed the same trend as TWA exposures to 1-BP: higher levels were observed for sprayers. Associations of AcPrCys concentrations, adjusted for creatinine, with 1-BP TWA exposure were statistically significant for both sprayers (P < 0.05) and non-sprayers (P < 0.01). Spearman correlation coefficients for AcPrCys and Br(−) analyses determined from the same urine specimens were highly correlated (P < 0.0001). This study confirms that urinary AcPrCys is an important 1-BP metabolite and an effective biomarker for highly exposed foam cushion workers. PMID:19706636

  20. The role of copper nanoparticles in an etch-and-rinse adhesive on antimicrobial activity, mechanical properties and the durability of resin-dentine interfaces.

    PubMed

    Gutiérrez, Mario F; Malaquias, Pamela; Hass, Viviane; Matos, Thalita P; Lourenço, Lucas; Reis, Alessandra; Loguercio, Alessandro D; Farago, Paulo Vitor

    2017-06-01

    To evaluate the effect of addition of copper nanoparticles at different concentrations into an etch-and-rinse adhesive (ER) on antimicrobial activity, Knoop microhardness (KHN), in vitro and in situ degree of conversion (DC), as well as the immediate (IM) and 2-year (2Y) resin-dentine bond strength (μTBS) and nanoleakage (NL). Seven experimental ER adhesives were formulated according to the amount of copper nanoparticles incorporated into the adhesives (0 [control], 0.0075 to 1wt.%). We tested the antimicrobial activity of adhesives against Streptococcus mutans using agar diffusion assay after IM and 2Y. The Knoop microhardness and in vitro DC were tested after IM and 2Y. The adhesives were applied to flat occlusal dentine surfaces after acid etching. After resin build-ups, specimens were longitudinally sectioned to obtain beam-like resin-dentine specimens (0.8mm 2 ), which were used for evaluation of μTBS and nanoleakage at the IM and 2Y periods. In situ DC was evaluated at the IM period in these beam-like specimens. Data were submitted to appropriate statistical analyses (α=0.05). The addition of copper nanoparticles provided antimicrobial activity to the adhesives only in the IM evaluation and slightly reduced the KHN, the in vitro and in situ DC (copper concentrations of 1wt.%). However, KHN increase for all concentrations after 2Y. After 2Y, no significant reductions of μTBS (0.06 to 1% wt.%) and increases of nanoleakage were observed for copper containing adhesives compared to the control group. Copper nanoparticles addition up to 0.5wt.% may provide antimicrobial properties to ER adhesives and prevent the degradation of the adhesive interface, without reducing the mechanical properties of the formulations. Copyright © 2017 Elsevier Ltd. All rights reserved.

Top