Science.gov

Sample records for spect technique sindrome

  1. Quantitative SPECT techniques.

    PubMed

    Watson, D D

    1999-07-01

    Quantitative imaging involves first, a set of measurements that characterize an image. There are several variations of technique, but the basic measurements that are used for single photon emission computed tomography (SPECT) perfusion images are reasonably standardized. Quantification currently provides only relative tracer activity within the myocardial regions defined by an individual SPECT acquisition. Absolute quantification is still a work in progress. Quantitative comparison of absolute changes in tracer uptake comparing a stress and rest study or preintervention and postintervention study would be useful and could be done, but most commercial systems do not maintain the data normalization that is necessary for this. Measurements of regional and global function are now possible with electrocardiography (ECG) gating, and this provides clinically useful adjunctive data. Techniques for measuring ventricular function are evolving and promise to provide clinically useful accuracy. The computer can classify images as normal or abnormal by comparison with a normal database. The criteria for this classification involve more than just checking the normal limits. The images should be analyzed to measure how far they deviate from normal, and this information can be used in conjunction with pretest likelihood to indicate the level of statistical certainty that an individual patient has a true positive or true negative test. The interface between the computer and the clinician interpreter is an important part of the process. Especially when both perfusion and function are being determined, the ability of the interpreter to correctly assimilate the data is essential to the use of the quantitative process. As we become more facile with performing and recording objective measurements, the significance of the measurements in terms of risk evaluation, viability assessment, and outcome should be continually enhanced. PMID:10433336

  2. SPECT and PET serve as molecular imaging techniques and in vivo biomarkers for brain metastases.

    PubMed

    Palumbo, Barbara; Buresta, Tommaso; Nuvoli, Susanna; Spanu, Angela; Schillaci, Orazio; Fravolini, Mario Luca; Palumbo, Isabella

    2014-06-03

    Nuclear medicine techniques (single photon emission computerized tomography, SPECT, and positron emission tomography, PET) represent molecular imaging tools, able to provide in vivo biomarkers of different diseases. To investigate brain tumours and metastases many different radiopharmaceuticals imaged by SPECT and PET can be used. In this review the main and most promising radiopharmaceuticals available to detect brain metastases are reported. Furthermore the diagnostic contribution of the combination of SPECT and PET data with radiological findings (magnetic resonance imaging, MRI) is discussed.

  3. SPECT and PET Serve as Molecular Imaging Techniques and in Vivo Biomarkers for Brain Metastases

    PubMed Central

    Palumbo, Barbara; Buresta, Tommaso; Nuvoli, Susanna; Spanu, Angela; Schillaci, Orazio; Fravolini, Mario Luca; Palumbo, Isabella

    2014-01-01

    Nuclear medicine techniques (single photon emission computerized tomography, SPECT, and positron emission tomography, PET) represent molecular imaging tools, able to provide in vivo biomarkers of different diseases. To investigate brain tumours and metastases many different radiopharmaceuticals imaged by SPECT and PET can be used. In this review the main and most promising radiopharmaceuticals available to detect brain metastases are reported. Furthermore the diagnostic contribution of the combination of SPECT and PET data with radiological findings (magnetic resonance imaging, MRI) is discussed. PMID:24897023

  4. [Radionuclide cisternography: SPECT- and 3D-technique].

    PubMed

    Henkes, H; Huber, G; Hierholzer, J; Cordes, M; Kujat, C; Piepgras, U

    1991-10-01

    Radionuclide cisternography is indicated in the clinical work-up for hydrocephalus, when searching for CSF leaks, and when testing whether or not intracranial cystic lesions are communicating with the adjacent subarachnoid space. This paper demonstrates the feasibility and diagnostic value of SPECT and subsequent 3D surface rendering in addition to conventional rectilinear CSF imaging in eight patients. Planar images allowed the evaluation of CSF circulation and the detection of CSF fistula. They were advantageous in examinations 48 h after application of 111In-DTPA. SPECT scans, generated 4-24 h after tracer application, were superior in the delineation of basal cisterns, especially in early scans; this was helpful in patients with pooling due to CSF fistula and in cystic lesions near the skull base. A major drawback was the limited image quality of delayed scans, when the SPECT data were degraded by a low count rate. 3D surface rendering was easily feasible from SPECT data and yielded high quality images. The presentation of the spatial distribution of nuclide-contaminated CSF proved especially helpful in the area of the basal cisterns. PMID:1956980

  5. Automated segmentation and registration technique for HMPAO-SPECT imaging of Alzheimer's patients

    NASA Astrophysics Data System (ADS)

    Radau, Perry E.; Slomka, Piotr J.; Julin, Per; Svensson, Leif; Wahlund, Lars-Olof

    2000-06-01

    We present an operator-independent software technique for segmentation, realignment and analysis of brain perfusion images, with both voxel-wise and regional quantitation methods. Inter-subject registration with normalized mutual information was tested with simulated defects. Brain perfusion images (HMPAO-SPECT) from 56 subjects (21 AD; 35 controls) were retrospectively analyzed. Templates were created from the 3-D registration of the controls. Automatic segmentation was developed to remove extraneous activity that disrupts registration. Two new registration methods, robust least squares (RLS) and normalized mutual information (NMI) were implemented and compared with sum of absolute differences (CD). The automatic segmentation method caused a registration displacement of 0.4 +/- 0.3 pixels compared with manual segmentation. NMI registration proved to be less adversely effected by simulated defects than RLS or CD. The error in quantitating the patient-template parietal ratio due to mis- registration was 2.0% and 0.5% for 70% and 85% hypoperfusion defects, respectively. The registration processing time was 1.6 min (233 MHz Pentium). The most accurate discriminant utilized a logistic equation parameterized by mean counts of the parietal and temporal regions of the map, (91 +/- 8% Se, 97 +/- 5% Sp). BRASS is a fast, objective software package for single-step analysis of brain SPECT, suitable to aid diagnosis of AD.

  6. Molecular SPECT Imaging: An Overview

    PubMed Central

    Khalil, Magdy M.; Tremoleda, Jordi L.; Bayomy, Tamer B.; Gsell, Willy

    2011-01-01

    Molecular imaging has witnessed a tremendous change over the last decade. Growing interest and emphasis are placed on this specialized technology represented by developing new scanners, pharmaceutical drugs, diagnostic agents, new therapeutic regimens, and ultimately, significant improvement of patient health care. Single photon emission computed tomography (SPECT) and positron emission tomography (PET) have their signature on paving the way to molecular diagnostics and personalized medicine. The former will be the topic of the current paper where the authors address the current position of the molecular SPECT imaging among other imaging techniques, describing strengths and weaknesses, differences between SPECT and PET, and focusing on different SPECT designs and detection systems. Radiopharmaceutical compounds of clinical as well-preclinical interest have also been reviewed. Moreover, the last section covers several application, of μSPECT imaging in many areas of disease detection and diagnosis. PMID:21603240

  7. Local and Non-local Regularization Techniques in Emission (PET/SPECT) Tomographic Image Reconstruction Methods.

    PubMed

    Ahmad, Munir; Shahzad, Tasawar; Masood, Khalid; Rashid, Khalid; Tanveer, Muhammad; Iqbal, Rabail; Hussain, Nasir; Shahid, Abubakar; Fazal-E-Aleem

    2016-06-01

    Emission tomographic image reconstruction is an ill-posed problem due to limited and noisy data and various image-degrading effects affecting the data and leads to noisy reconstructions. Explicit regularization, through iterative reconstruction methods, is considered better to compensate for reconstruction-based noise. Local smoothing and edge-preserving regularization methods can reduce reconstruction-based noise. However, these methods produce overly smoothed images or blocky artefacts in the final image because they can only exploit local image properties. Recently, non-local regularization techniques have been introduced, to overcome these problems, by incorporating geometrical global continuity and connectivity present in the objective image. These techniques can overcome drawbacks of local regularization methods; however, they also have certain limitations, such as choice of the regularization function, neighbourhood size or calibration of several empirical parameters involved. This work compares different local and non-local regularization techniques used in emission tomographic imaging in general and emission computed tomography in specific for improved quality of the resultant images.

  8. Adaptive SPECT

    PubMed Central

    Barrett, Harrison H.; Furenlid, Lars R.; Freed, Melanie; Hesterman, Jacob Y.; Kupinski, Matthew A.; Clarkson, Eric; Whitaker, Meredith K.

    2008-01-01

    Adaptive imaging systems alter their data-acquisition configuration or protocol in response to the image information received. An adaptive pinhole single-photon emission computed tomography (SPECT) system might acquire an initial scout image to obtain preliminary information about the radiotracer distribution and then adjust the configuration or sizes of the pinholes, the magnifications, or the projection angles in order to improve performance. This paper briefly describes two small-animal SPECT systems that allow this flexibility and then presents a framework for evaluating adaptive systems in general, and adaptive SPECT systems in particular. The evaluation is in terms of the performance of linear observers on detection or estimation tasks. Expressions are derived for the ideal linear (Hotelling) observer and the ideal linear (Wiener) estimator with adaptive imaging. Detailed expressions for the performance figures of merit are given, and possible adaptation rules are discussed. PMID:18541485

  9. A technique using {sup 99m}Tc-mebrofenin SPECT for radiotherapy treatment planning for liver cancers or metastases

    SciTech Connect

    Shen, Sui; Jacob, Rojymon; Bender, Luvenia W.; Duan, Jun; Spencer, Sharon A.

    2014-04-01

    Radiotherapy or stereotactic body radiosurgery (SBRT) requires a sufficient functional liver volume to tolerate the treatment. The current study extended the work of de Graaf et al. (2010) [3] on the use of {sup 99m}Tc-mebrofenin imaging for presurgery planning to radiotherapy planning for liver cancer or metastases. Patient was immobilized and imaged in an identical position on a single-photon emission computed tomography/computed tomography (SPECT-CT) system and a radiotherapy simulation CT system. {sup 99m}Tc-mebrofenin SPECT was registered to the planning CT through image registration of noncontrast CT from SPECT-CT system to the radiotherapy planning CT. The voxels with higher uptake of {sup 99m}Tc-mebrofenin were transferred to the planning CT as an avoidance structure in optimizing a 2-arc RapidArc plan for SBRT delivery. Excellent dose coverage to the target and sparing of the healthy remnant liver volume was achieved. This report illustrated a procedure for the use of {sup 99m}Tc-mebrofenin SPECT for optimizing radiotherapy for liver cancers and metastases.

  10. Optimal Methodology of SPECT/CT Acquisition and Processing Technique for 123I-DaTSCAN Neuroimaging

    NASA Astrophysics Data System (ADS)

    Siennicki, Jakub; Bieńkiewicz, Małgorzata; Płachcińska, Anna

    2010-01-01

    The aim of this study was to evaluate the effect of ordered-subset expectation maximization reconstruction algorithm with scatter correction and attenuation correction based on computed tomography maps and to find out the optimum number of subsets and iterations upon image quality for 123I-DaTSCAN neuroimaging. We retrospectively studied SPECT/CT scans of 44 consecutive patients with clinical indications of Parkinson's disease. Images were reconstructed with use of two methods: filtered back projection and OSEM. Image quality was assessed by: striatal binding indices as a measure of contrast and coefficients of variation as a measure of noise. The quality of DaTSCAN images reconstructed with the use of OSEM (4iter/10subs) with reconstruction corrections was superior to that provided by the commonly applied FBP.

  11. Regional cerebral blood flow (RCBF) measurements by SPECT analysis of Xenon-133 transit: Validation of technique and clinical correlation

    SciTech Connect

    Rezai, K.; Kirchner, P.; Armstrong, C.; Ehrhardt, J.; Damasio, H.; Adams, H.; Damasio, A.

    1984-01-01

    The SPECT system (Tomomatic-64) developed by a previous study for rCBF measurements with Xe-133 was validated with phantom simulations and clinical studies. A bi-compartmental flow phantom was developed consisting of a Xenon-133 pump connected in series to head and lung compartments. Flow rates between 0.2 and 1.4 brain volumes/min (20-140 cc/100ml/min) were tested against Tomomatic measurements by linear regression. Correlation was excellent (r=1.0) in the range of 0.2-1.2 (20-120 cc/100ml/min), representing flow rates which are most likely to be encountered in clinical studies. Flow rates above 1.2 (120 cc/100 ml/min) were significantly underestimated. 32 studies on 20 volunteers gave a mean normal flow of 72 (SD=12) cc/ 100g/min. Mean regional flow ranged from 62 in frontal lobes to 75 in central gray matter. Right-to-left variation was less than 5%. The lowest regional flow in a normal subject was 45 cc/100g/min. 68 studies were performed on 30 stroke patients. In 27 rCBF was less than 45 in affected brain areas for a sensitivity of 90% which improved to 97% when comparisons with contralateral brain were included. Initial CT scans were normal or non-diagnostic in 10, but showed CVA's in regions of reduced rCBF in 17 patients. rCBF abnormalities involved greater portions of brain than CT changes, often (8/17) including distant regions, unpredicted by CT or clinical studies but known to be strongly interconnected to the area of structural damage. SPECT estimates of rCBF appear to be a sensitive research and diagnostic tool and complement the structural information provided by CT.

  12. SPECT in the diagnosis of hepatic hemangioma

    SciTech Connect

    Brunetti, J.C.; Van Heertum, R.L.; Yudd, A.P.

    1985-05-01

    Tc99m labeled red blood cell blood flow and delayed static blood pool imaging is widely accepted as a reliable, accurate method for the diagnosis of hepatic hemangiomata. The purpose of this study is to assess the relative value of SPECT blood pool imaging in the evaluation of hepatic hemangionata. A total of 68 patients, including 21 patients with proven hepatic cavernous hemangiomas, were studied using both planar and SPECT imaging techniques. All patients underwent multi-phase evaluation which included a hepatic flow study, immediate planar images of the liver, followed by a 360/sup 0/ tomographic (SPECT) study and subsequent 60 minute delayed static planar hepatic blood pool images. All 21 patients with proven hepatic hemangiomas had a positive SPECT exam and 17 of the 21 (81%) patients had a positive planar exam. In the 21 patients, there were a total of 36 hemangiomas ranging in size from .7 cm to 13 cm. The SPECT imaging technique correctly identified all 36 lesions (100%) where as planar imaging detected 25 of the 36 lesions (69.4%). In all the remaining patients (10-normal, 17-metastatic disease, 12-hepatocellular disease, 6-hepatoma, 2-liver cysts), both the planar and SPECT imaging techniques were interpreted as showing no evidence of focal sequestration of red blood cells. SPECT hepatic blood pool imaging represents an improvement in the evaluation of hepatic hemangioma as a result of a reduction in imaging time (less than thirty minutes), improved spatial resolution and greater overall accuracy.

  13. NOTE: Comparison of correction techniques for simultaneous 201Tl/99mTc myocardial perfusion SPECT imaging: a dog study

    NASA Astrophysics Data System (ADS)

    Knesaurek, Karin; Machac, Josef

    2000-11-01

    We compared two correction methods for simultaneous 201Tl/99mTc dual-isotope single-photon emission computed tomography (SPECT). Both approaches use the information from the third energy window placed between the photopeak windows of the 201Tl and 99mTc. The first approach, described by Moore et al, corrects only for the contribution of the 99mTc to the 201Tl primary 70 keV window. We developed the three-window transformation dual-isotope correction method, which is a simultaneous cross-talk correction. The two correction methods were compared in a simultaneous 201Tl/99mTc sestamibi cardiac dog study. Three separate acquisitions were performed in this dog study: two single-isotope and one dual-isotope acquisition. The 201Tl single-isotope images were used as references. The total number of counts, and the contrast between the left ventricular cavity (LVC) and the myocardium, were used in 70 keV short-axis slices as parameters for evaluating the results of the dual-isotope correction methods. Three consecutive short-axis slices were used to calculate averaged contrast and the averaged total number of counts. The total number of the counts was 667 000 ± 500 and 414 500 ± 400 counts for the dual-isotope (201Tl + 99mTc) and single-isotope (201Tl-only) 70 keV images, respectively. The corrected dual-isotope images had 514 700 ± 700 and 368 000 ± 600 counts for Moore's correction and our approach, respectively. Moore's method improved contrast in the dual-isotope 70 keV image to 0.14 ± 0.03 from 0.11 ± 0.02, which was the value in the 70 keV non-corrected dual-isotope image. Our method improved the same contrast to 0.22 ± 0.03. The contrast in the 201Tl single-isotope 70 keV image was 0.28 ± 0.02. Both methods improved the 70 keV dual-isotope images. However, our approach provided slightly better images than Moore's correction when compared with 201Tl-only 70 keV images.

  14. Single photon emission computed tomography (SPECT) in epilepsy

    SciTech Connect

    Leroy, R.F.

    1991-12-31

    Epilepsy is a common neurologic disorder which has just begun to be studied with single photon emission computerized tomography (SPECT). Epilepsy usually is studied with electroencephalographic (EEG) techniques that demonstrate the physiologic changes that occur during seizures, and with neuroimaging techniques that show the brain structures where seizures originate. Neither method alone has been adequate to describe the pathophysiology of the patient with epilepsy. EEG techniques lack anatomic sensitivity, and there are no structural abnormalities shown by neuroimaging which are specific for epilepsy. Functional imaging (FI) has developed as a physiologic tool with anatomic sensitivity, and SPECT has been promoted as a FI technique because of its potentially wide availability. However, SPECT is early in its development and its clinical utility for epilepsy still has to be demonstrated. To understand this role of SPECT, consideration must be given to the pathophysiology of epilepsy, brain physiology, types of seizure, epileptic syndromes, and the SPECT technique itself. 44 refs., 2 tabs.

  15. I-123 Iofetamine SPECT scan in children with neurological disorders

    SciTech Connect

    Flamini, J.R.; Konkol, R.J.; Wells, R.G.; Sty, J.R. )

    1990-10-01

    I-123 Iofetamine (IMP) single photon emission computed tomography (SPECT) imaging of the brain in 42 patients (ages 14 days to 23 years) was compared with other localizing studies in children with neurological diseases. All had an EEG and at least one imaging study of the brain (computed tomography (CT) or magnetic resonance imaging (MRI), or both). Seventy-eight percent of the patients had an EEG within 24-72 hours of the IMP-SPECT scan. Thirty-five (83%) had a history of seizures, and the remainder had other neurological conditions without a history of seizures. In most cases, a normal EEG reading with normal CT or MRI result predicted a normal SPECT study. When the EEG was abnormal the majority of the IMP-SPECT scans were abnormal and localized the abnormality to the same region. A comparison with CT and MRI showed that structural abnormalities involving the cortex were usually well demonstrated with IMP-SPECT imaging. Structural lesions confined to the white matter were generally not detectable with IMP-SPECT. In a few cases, SPECT scans revealed abnormalities in deep brain areas not identified by EEG. IMP-SPECT imaging is a valuable technique for the detection and localization of abnormal cerebral metabolic activity in children with seizure disorders. A correlation with CT or MRI is essential for proper interpretation of abnormalities detected with IMP SPECT imaging.

  16. Assessment of cardiac function using myocardial perfusion imaging technique on SPECT with 99mTc sestamibi

    NASA Astrophysics Data System (ADS)

    Gani, M. R. A.; Nazir, F.; Pawiro, S. A.; Soejoko, D. S.

    2016-03-01

    Suspicion on coronary heart disease can be confirmed by observing the function of left ventricle cardiac muscle with Myocardial Perfusion Imaging techniques. The function perfusion itself is indicated by the uptake of radiopharmaceutical tracer. The 31 patients were studied undergoing the MPI examination on Gatot Soebroto Hospital using 99mTc-sestamibi radiopharmaceutical with stress and rest conditions. Stress was stimulated by physical exercise or pharmacological agent. After two hours, the patient did rest condition on the same day. The difference of uptake percentage between stress and rest conditions will be used to determine the malfunction of perfusion due to ischemic or infarct. Degradation of cardiac function was determined based on the image-based assessment of five segments of left ventricle cardiac. As a result, 8 (25.8%) patients had normal myocardial perfusion and 11 (35.5%) patients suspected for having partial ischemia. Total ischemia occurred to 8 (25.8%) patients with reversible and irreversible ischemia and the remaining 4 (12.9%) patients for partial infarct with characteristic the percentage of perfusion ≤50%. It is concluded that MPI technique of image-based assessment on uptake percentage difference between stress and rest conditions can be employed to predict abnormal perfusion as complementary information to diagnose the cardiac function.

  17. Ineffectiveness of dipyridamole SPECT thallium imaging as a screening technique for coronary artery disease in patients with end-stage renal failure

    SciTech Connect

    Marwick, T.H.; Steinmuller, D.R.; Underwood, D.A.; Hobbs, R.E.; Go, R.T.; Swift, C.; Braun, W.E. )

    1990-01-01

    The efficacy of dipyridamole single photon emission computed tomography (SPECT) thallium as a screening test for coronary artery disease (CAD), was studied in 45 patients with end-stage renal failure undergoing evaluation for renal transplantation. Coronary arteriography, dipyridamole SPECT thallium imaging and clinical follow-up were performed in all patients. Nineteen patients (42%) had an obstruction of 50% or more in at least one coronary artery. Fourteen patients had a positive thallium scan, but 7 of these were false-positives (sensitivity 37%, specificity 73%). The sensitivity was considerably lower than that quoted for non-ESRF patients in the literature, and significantly lower than a control group of 19 patients without ESRF having comparable severity and distribution of CAD. Five of the 6 patients who died of cardiac causes over a mean follow-up period of 25 months had normal thallium imaging, but all had significant coronary artery disease at cardiac catheterization. Dipyridamole SPECT thallium imaging has not proved a useful screening test for angiographically significant CAD, and does not predict cardiac prognosis in this population.

  18. Abdominal SPECT imaging

    SciTech Connect

    Van Heertum, R.L.; Brunetti, J.C.; Yudd, A.P.

    1987-07-01

    Over the past several years, abdominal single photon emission computed tomography (SPECT) imaging has evolved from a research tool to an important clinical imaging modality that is helpful in the diagnostic assessment of a wide variety of disorders involving the abdominal viscera. Although liver-spleen imaging is the most popular of the abdominal SPECT procedures, blood pool imaging is becoming much more widely utilized for the evaluation of cavernous hemangiomas of the liver as well as other vascular abnormalities in the abdomen. Adjunctive indium leukocyte and gallium SPECT studies are also proving to be of value in the assessment of a variety of infectious and neoplastic diseases. As more experience is acquired in this area, SPECT should become the primary imaging modality for both gallium and indium white blood cells in many institutions. Renal SPECT, on the other hand, has only recently been used as a clinical imaging modality for the assessment of such parameters as renal depth and volume. The exact role of renal SPECT as a clinical tool is, therefore, yet to be determined. 79 references.

  19. MR-based keyhole SPECT for small animal imaging

    PubMed Central

    Lee, Keum Sil; Roeck, Werner W; Gullberg, Grant T; Nalcioglu, Orhan

    2011-01-01

    The rationale for multi-modality imaging is to integrate the strengths of different imaging technologies while reducing the shortcomings of an individual modality. The work presented here proposes a limited-field-of-view (LFOV) SPECT reconstruction technique that can be implemented on a multi-modality MR/SPECT system that can be used to obtain simultaneous MRI and SPECT images for small animal imaging. The reason for using a combined MR/SPECT system in this work is to eliminate any possible misregistration between the two sets of images when MR images are used as a priori information for SPECT. In nuclear imaging the target area is usually smaller than the entire object; thus, focusing the detector on the LFOV results in various advantages including the use of a smaller nuclear detector (less cost), smaller reconstruction region (faster reconstruction) and higher spatial resolution when used in conjunction with pinhole collimators with magnification. The MR/SPECT system can be used to choose a region of interest (ROI) for SPECT. A priori information obtained by the full field-of-view (FOV) MRI combined with the preliminary SPECT image can be used to reduce the dimensions of the SPECT reconstruction by limiting the computation to the smaller FOV while reducing artifacts resulting from the truncated data. Since the technique is based on SPECT imaging within the LFOV it will be called the keyhole SPECT (K-SPECT) method. At first MRI images of the entire object using a larger FOV are obtained to determine the location of the ROI covering the target organ. Once the ROI is determined, the animal is moved inside the radiofrequency (rf) coil to bring the target area inside the LFOV and then simultaneous MRI and SPECT are performed. The spatial resolution of the SPECT image is improved by employing a pinhole collimator with magnification >1 by having carefully calculated acceptance angles for each pinhole to avoid multiplexing. In our design all the pinholes are focused to

  20. Rodent brain imaging with SPECT/CT

    SciTech Connect

    Seo, Youngho; Gao, D.-W.; Hasegawa, Bruce H.; Dae, Michael W.; Franc, Benjamin L.

    2007-04-15

    We evaluated methods of imaging rat models of stroke in vivo using a single photon emission computed tomography (SPECT) system dedicated to small animal imaging (X-SPECT{sup TM}, Gamma Medica-Ideas, Northridge, CA). An animal model of ischemic stroke was developed for in vivo SPECT/CT imaging using the middle cerebral artery occlusion (MCAO) technique. The presence of cerebral ischemia was verified in ex vivo studies using triphenyltetrazolium chloride (TTC) staining. In vivo radionuclide imaging of cerebral blood flow was performed in rats following MCAO using dynamic planar imaging of {sup 99m}Tc-exametazime with parallel hole collimation. This was followed immediately by in vivo radionuclide imaging of cerebral blood flow with {sup 99m}Tc-exametazime in the same animals using 1-mm pinhole SPECT. Correlated computed tomography imaging was performed to localize radiopharmaceutical uptake. The animals were allowed to recover and ex vivo autoradiography was performed with separate administration of {sup 99m}Tc-exametazime. Time activity curve of {sup 99m}Tc-exametazime showed that the radiopharmaceutical uptake could be maintained for over 9 min. The activity would be expected to be relatively stable for a much longer period, although the data were only obtained for 9 min. TTC staining revealed sizable infarcts by visual observation of inexistence of TTC stain in infracted tissues of MCAO rat brains. In vivo SPECT imaging showed cerebral blood flow deficit in the MCAO model, and the in vivo imaging result was confirmed with ex vivo autoradiography. We have demonstrated a capability of imaging regions of cerebral blood flow deficit in MCAO rat brains in vivo using a pinhole SPECT dedicated to small animal imaging.

  1. Rodent brain imaging with SPECT/CT.

    PubMed

    Seo, Youngho; Gao, Dong-Wei; Hasegawa, Bruce H; Dae, Michael W; Franc, Benjamin L

    2007-04-01

    We evaluated methods of imaging rat models of stroke in vivo using a single photon emission computed tomography (SPECT) system dedicated to small animal imaging (X-SPECT, Gamma Medica-Ideas, Northridge, CA). An animal model of ischemic stroke was developed for in vivo SPECT/CT imaging using the middle cerebral artery occlusion (MCAO) technique. The presence of cerebral ischemia was verified in ex vivo studies using triphenyltetrazolium chloride (TTC) staining. In vivo radionuclide imaging of cerebral blood flow was performed in rats following MCAO using dynamic planar imaging of 99mTc-exametazime with parallel hole collimation. This was followed immediately by in vivo radionuclide imaging of cerebral blood flow with 99mTc-exametazime in the same animals using 1-mm pinhole SPECT. Correlated computed tomography imaging was performed to localize radiopharmaceutical uptake. The animals were allowed to recover and ex vivo autoradiography was performed with separate administration of 99mTc-exametazime. Time activity curve of 99mTc-exametazime showed that the radiopharmaceutical uptake could be maintained for over 9 min. The activity would be expected to be relatively stable for a much longer period, although the data were only obtained for 9 min. TTC staining revealed sizable infarcts by visual observation of inexistence of TTC stain in infracted tissues of MCAO rat brains. In vivo SPECT imaging showed cerebral blood flow deficit in the MCAO model, and the in vivo imaging result was confirmed with ex vivo autoradiography. We have demonstrated a capability of imaging regions of cerebral blood flow deficit in MCAO rat brains in vivo using a pinhole SPECT dedicated to small animal imaging.

  2. PET and SPECT imaging in veterinary medicine.

    PubMed

    LeBlanc, Amy K; Peremans, Kathelijne

    2014-01-01

    Veterinarians have gained increasing access to positron emission tomography (PET and PET/CT) imaging facilities, allowing them to use this powerful molecular imaging technique for clinical and research applications. SPECT is currently being used more in Europe than in the United States and has been shown to be useful in veterinary oncology and in the evaluation of orthopedic diseases. SPECT brain perfusion and receptor imaging is used to investigate behavioral disorders in animals that have interesting similarities to human psychiatric disorders. This article provides an overview of the potential applications of PET and SPECT. The use of commercially available and investigational PET radiopharmaceuticals in the management of veterinary disease has been discussed. To date, most of the work in this field has utilized the commercially available PET tracer, (18)F-fluorodeoxyglucose for oncologic imaging. Normal biodistribution studies in several companion animal species (cats, dogs, and birds) have been published to assist in lesion detection and interpretation for veterinary radiologists and clinicians. Studies evaluating other (18)F-labeled tracers for research applications are underway at several institutions and companion animal models of human diseases are being increasingly recognized for their value in biomarker and therapy development. Although PET and SPECT technologies are in their infancy for clinical veterinary medicine, increasing access to and interest in these applications and other molecular imaging techniques has led to a greater knowledge and collective body of expertise for veterinarians worldwide. Initiation and fostering of physician-veterinarian collaborations are key components to the forward movement of this field.

  3. Proceedings of clinical SPECT (single photon emission computed tomography) symposium

    SciTech Connect

    Not Available

    1986-09-01

    It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have selected the key areas which demand awareness and attention in order to make SPECT operational in clinical practice. These include selection of equipment, details of uniformity correction, utilization of phantoms for equipment acceptance and quality assurance, the major aspect of algorithms, an understanding of filtered back projection and appropriate choice of filters and an awareness of the most commonly generated artifacts and how to recognize them. With respect to the acquisition and interpretation of organ images, the faculty will present information on the major aspects of hepatic, brain, cardiac, skeletal, and immunologic imaging techniques. Individual papers are processed separately for the data base. (TEM)

  4. Using adaptive neuro-fuzzy inference system technique for crosstalk correction in simultaneous 99mTc/201Tl SPECT imaging: A Monte Carlo simulation study

    NASA Astrophysics Data System (ADS)

    Heidary, Saeed; Setayeshi, Saeed

    2015-01-01

    This work presents a simulation based study by Monte Carlo which uses two adaptive neuro-fuzzy inference systems (ANFIS) for cross talk compensation of simultaneous 99mTc/201Tl dual-radioisotope SPECT imaging. We have compared two neuro-fuzzy systems based on fuzzy c-means (FCM) and subtractive (SUB) clustering. Our approach incorporates eight energy-windows image acquisition from 28 keV to 156 keV and two main photo peaks of 201Tl (77±10% keV) and 99mTc (140±10% keV). The Geant4 application in emission tomography (GATE) is used as a Monte Carlo simulator for three cylindrical and a NURBS Based Cardiac Torso (NCAT) phantom study. Three separate acquisitions including two single-isotopes and one dual isotope were performed in this study. Cross talk and scatter corrected projections are reconstructed by an iterative ordered subsets expectation maximization (OSEM) algorithm which models the non-uniform attenuation in the projection/back-projection. ANFIS-FCM/SUB structures are tuned to create three to sixteen fuzzy rules for modeling the photon cross-talk of the two radioisotopes. Applying seven to nine fuzzy rules leads to a total improvement of the contrast and the bias comparatively. It is found that there is an out performance for the ANFIS-FCM due to its acceleration and accurate results.

  5. Hybrid SPECT/CT imaging in neurology.

    PubMed

    Ciarmiello, Andrea; Giovannini, Elisabetta; Meniconi, Martina; Cuccurullo, Vincenzo; Gaeta, Maria Chiara

    2014-01-01

    In recent years, the SPECT/CT hybrid modality has led to a rapid development of imaging techniques in nuclear medicine, opening new perspectives for imaging staff and patients as well. However, while, the clinical role of positron emission tomography-computed tomography (PET-CT) is well consolidated, the diffusion and the consequent value of single-photon emission tomography-computed tomography (SPECT-CT) has yet to be weighed, Hence, there is a need for a careful analysis, comparing the "potential" benefits of the hybrid modality with the "established" ones of the standalone machine. The aim of this article is to analyze the impact of this hybrid tool on the diagnosis of diseases of the central nervous system, comparing strengths and weaknesses of both modalities through the use of SWOT analysis. PMID:25143053

  6. Enhanced cross-talk correction technique for simultaneous dual-isotope imaging: a TL-201/Tc-99m myocardial perfusion SPECT dog study.

    PubMed

    Knesaurek, K; Machac, J

    1997-12-01

    A newly developed cross-talk correction method for simultaneous dual-isotope SPECT imaging was tested in a canine model. The method is based on the assumption that the transformations, which modify the primary energy window images into the scatter images as viewed in the other energy windows, are known. These transformations were found by measuring the point spread functions (PSFs) in two different energy windows for both isotopes in water. The dual-isotope correction method is described by two convolution equations which were applied in frequency space. The equations take into account the different spatial distributions of the primary and scatter cross-talk photons. The new enhancement of the method was in applying restoration filters to the resulting corrected images. Three separate studies were acquired in our dog study: two single-isotope and one dual-isotope study. The single isotope images were used as references. The contrast between the left ventricle cavity (LVC) and the myocardium was used in transaxial and short-axis slices as a parameter to evaluate results of dual-isotope correction method with restoration. The change in contrast in the dual-isotope corrected images in both energy windows, i.e., Tc-99m primary window (140 keV) and Tl-201 primary window (70 keV), was significant. The only exception was for the short-axis Tc-99m window images. The corrected 140 keV dual-isotope short-axis slice had the contrast of 0.60 vs 0.58, which was the value in the noncorrected dual-isotope short-axis slice. For dual-isotope 140 keV transaxial slice, the contrast changed from 0.72 to 0.82 after correction. In comparison, for single-isotope Tc-99m 140 keV transaxial slice, contrast changed from 0.62 to 0.84 after restoration correction. There was less change in contrast in the short-axis Tc-99m 140 keV slice, i.e., from 0.56 to 0.61. In the Tl-201 primary window for the transaxial slices the improvement of contrast was from 0.38 to 0.64, and for short-axis slices

  7. Accelerated GPU based SPECT Monte Carlo simulations

    NASA Astrophysics Data System (ADS)

    Garcia, Marie-Paule; Bert, Julien; Benoit, Didier; Bardiès, Manuel; Visvikis, Dimitris

    2016-06-01

    Monte Carlo (MC) modelling is widely used in the field of single photon emission computed tomography (SPECT) as it is a reliable technique to simulate very high quality scans. This technique provides very accurate modelling of the radiation transport and particle interactions in a heterogeneous medium. Various MC codes exist for nuclear medicine imaging simulations. Recently, new strategies exploiting the computing capabilities of graphical processing units (GPU) have been proposed. This work aims at evaluating the accuracy of such GPU implementation strategies in comparison to standard MC codes in the context of SPECT imaging. GATE was considered the reference MC toolkit and used to evaluate the performance of newly developed GPU Geant4-based Monte Carlo simulation (GGEMS) modules for SPECT imaging. Radioisotopes with different photon energies were used with these various CPU and GPU Geant4-based MC codes in order to assess the best strategy for each configuration. Three different isotopes were considered: 99m Tc, 111In and 131I, using a low energy high resolution (LEHR) collimator, a medium energy general purpose (MEGP) collimator and a high energy general purpose (HEGP) collimator respectively. Point source, uniform source, cylindrical phantom and anthropomorphic phantom acquisitions were simulated using a model of the GE infinia II 3/8" gamma camera. Both simulation platforms yielded a similar system sensitivity and image statistical quality for the various combinations. The overall acceleration factor between GATE and GGEMS platform derived from the same cylindrical phantom acquisition was between 18 and 27 for the different radioisotopes. Besides, a full MC simulation using an anthropomorphic phantom showed the full potential of the GGEMS platform, with a resulting acceleration factor up to 71. The good agreement with reference codes and the acceleration factors obtained support the use of GPU implementation strategies for improving computational efficiency

  8. Parallel-hole collimator concept for stationary SPECT imaging

    NASA Astrophysics Data System (ADS)

    Pato, Lara R. V.; Vandenberghe, Stefaan; Zedda, Tiziana; Van Holen, Roel

    2015-11-01

    Parallel-hole SPECT collimators have traditionally been manufactured by stacking sheets of lead foil or by casting. These techniques significantly restrict our options in terms of collimator geometry. However, recent developments in metal additive manufacturing are making novel collimator designs possible, giving rise to new opportunities in SPECT imaging. In this paper we propose an innovative type of collimator for stationary SPECT, using parallel-holes whose collimation direction depends on their axial position. Its main advantage compared to current stationary SPECT systems (which are based on pinholes) is that, using only axial bed translations, we can achieve complete angular sampling of an increased portion of the transaxial area of the collimator bore. This allows the system to be much more compact than current stationary SPECT systems that image objects of the same size. We describe three possible designs, for full-body, brain and small-animal imaging, respectively, and test their feasibility using simulations. The system modeling method is validated against realistic Monte Carlo simulations, and then used in the evaluation of the systems’ performances and reconstructions. The simulations show that the system is able to reconstruct objects occupying the predicted field of view (75% of the transaxial area of the bore) without sampling artifacts. In particular, we perform reconstructions from noisy projection data obtained for an activity and scanning time similar to standard protocols for the three applications, and the resulting images indicate the possibility of using the proposed systems in practice.

  9. A multiresolution restoration method for cardiac SPECT

    NASA Astrophysics Data System (ADS)

    Franquiz, Juan Manuel

    method was also assessed in 201Tl clinical SPECT studies. Phantom results demonstrated that the multiresolution algorithm compensated the liver spillover artifact, yielded uniform polar maps and improved significantly the accuracy in calculating myocardial defect size. The procedure does not require operator intervention and can be easily implemented in the clinical setting by using Fourier transform techniques. Finally, the extension of the multiresolution method to other SPECT procedures is discussed and recommended.

  10. Radiopharmaceuticals for SPECT Cancer Detection

    NASA Astrophysics Data System (ADS)

    Chernov, V. I.; Medvedeva, A. A.; Zelchan, R. V.; Sinilkin, I. G.; Stasyuk, E. S.; Larionova, L. A.; Slonimskaya, E. M.; Choynzonov, E. L.

    2016-06-01

    The purpose of the study was to assess the efficacy of single photon emission computed tomography (SPECT) with 199Tl and 99mTc-MIBI in the detection of breast, laryngeal and hypopharyngeal cancers. Materials and Methods: a total of 220 patients were included into the study. Of them, there were 120 patients with breast lesions (100 patients with breast cancer and 20 patients with benign breast tumors) and '00 patients with laryngeal/hypopharyngeal diseases (80 patients with laryngeal/hypopharyngeal cancer and 20 patients with benign laryngeal/hypopharyngeal lesions). Results: no abnormal 199Tl uptake was seen in all patients with benign breast and laryngeal lesions, indicating a 100% specificity of 199Tl SPECT. In breast cancer patients, increased 199Tl uptake in the breast was visualized in 94.8% patients, 99mTc-MIBI in 93.4% patients. Increased 199Tl uptake in axillary lymph nodes was detected in 60% patients and 99mTc-MIBI in 93.1% patients. In patients with laryngeal/hypopharyngeal cancer, sensitivity of SPECT with 199Tl and 99mTc-MIBI were 95%. The 199Tl SPECT sensitivity in identification of regional lymph node metastases in patients with laryngeal/hypopharyngeal cancer was 75% and the 99mTc-MIBI SPECT sensitivity was 17%. Conclusion: the data obtained show that SPECT with 199Tl and 99mTc-MIBI can be used as one of the additional imaging methods in detection of tumors.

  11. Radiopharmaceuticals for SPECT cancer detection

    NASA Astrophysics Data System (ADS)

    Chernov, V. I.; Medvedeva, A. A.; Zelchan, R. V.; Sinilkin, I. G.; Stasyuk, E. S.; Larionova, L. A.; Slonimskaya, E. M.; Choynzonov, E. L.

    2016-08-01

    The purpose of the study was to assess the efficacy of single photon emission computed tomography (SPECT) with 199Tl and 99mTc-MIBI in the detection of breast, laryngeal and hypopharyngeal cancers. A total of 220 patients were included into the study: 120 patients with breast lesions (100 patients with breast cancer and 20 patients with benign breast tumors) and 100 patients with laryngeal/hypopharyngeal diseases (80 patients with laryngeal/hypopharyngeal cancer and 20 patients with benign laryngeal/hypopharyngeal lesions). No abnormal 199Tl uptake was seen in all patients with benign breast and laryngeal lesions, indicating a 100% specificity of 199Tl SPECT. In the breast cancer patients, the increased 199Tl uptake in the breast was visualized in 94.8% patients, 99mTc-MIBI—in 93.4% patients. The increased 199Tl uptake in axillary lymph nodes was detected in 60% patients, and 99mTc-MIBI—in 93.1% patients. In patients with laryngeal/hypopharyngeal cancer, the sensitivity of SPECT with 199Tl and 99mTc-MIBI was 95%. The 199Tl SPECT sensitivity in identification of regional lymph node metastases in the patients with laryngeal/hypopharyngeal cancer was 75% and the 99mTc-MIBI SPECT sensitivity was 17%. The data obtained showed that SPECT with 199Tl and 99mTc-MIBI can be used as one of the additional imaging methods in detection of tumors.

  12. A COMPUTER MODEL OF LUNG MORPHOLOGY TO ANALYZE SPECT IMAGES

    EPA Science Inventory

    Measurement of the three-dimensional (3-D) spatial distribution of aerosol deposition can be performed using Single Photon Emission Computed Tomography (SPECT). The advantage of using 3-D techniques over planar gamma imaging is that deposition patterns can be related to real lun...

  13. Less commonly used and emerging clinical applications of SPECT-CT in benign and malignant disease.

    PubMed

    Yap, Ki S; Patel, Chirag N; Chowdhury, Fahmid U; Scarsbrook, Andrew F

    2012-08-01

    The emergence of hybrid imaging, combining anatomical computed tomography (CT) and functional single-photon emission computed tomography (SPECT), has greatly expanded the armoury available to image disease. Integrated SPECT-CT is a dual-modality technique, which improves the sensitivity and specificity of existing radionuclide studies and enables characterization of equivocal findings detected by conventional imaging. There is a wide range of established and emerging clinical applications for SPECT-CT, which were reviewed in detail at a symposium organized by the British Institute of Radiology in March 2012. A series of articles were commissioned as an adjunct to the symposium and to raise awareness of the clinical utility of this technique. The focus of this article is on less commonly used and emerging clinical applications of hybrid SPECT-CT in a spectrum of benign and malignant conditions. The article will illustrate the incremental value of the technique in a variety of clinical applications.

  14. Progress in SPECT/CT imaging of prostate cancer.

    PubMed

    Seo, Youngho; Franc, Benjamin L; Hawkins, Randall A; Wong, Kenneth H; Hasegawa, Bruce H

    2006-08-01

    Prostate cancer is the most common type of cancer (other than skin cancer) among men in the United States. Although prostate cancer is one of the few cancers that grow so slowly that it may never threaten the lives of some patients, it can be lethal once metastasized. Indium-111 capromab pendetide (ProstaScint, Cytogen Corporation, Princeton, NJ) imaging is indicated for staging and recurrence detection of the disease, and is particularly useful to determine whether or not the disease has spread to distant metastatic sites. However, the interpretation of 111In-capromab pendetide is challenging without correlated structural information mostly because the radiopharmaceutical demonstrates nonspecific uptake in the normal vasculature, bowel, bone marrow, and the prostate gland. We developed an improved method of imaging and localizing 111In-Capromab pendetide using a SPECT/CT imaging system. The specific goals included: i) development and application of a novel iterative SPECT reconstruction algorithm that utilizes a priori information from coregistered CT; and ii) assessment of clinical impact of adding SPECT/CT for prostate cancer imaging with capromab pendetide utilizing the standard and novel reconstruction techniques. Patient imaging studies with capromab pendetide were performed from 1999 to 2004 using two different SPECT/CT scanners, a prototype SPECT/CT system and a commercial SPECT/CT system (Discovery VH, GE Healthcare, Waukesha, WI). SPECT projection data from both systems were reconstructed using an experimental iterative algorithm that compensates for both photon attenuation and collimator blurring. In addition, the data obtained from the commercial system were reconstructed with attenuation correction using an OSEM reconstruction supplied by the camera manufacturer for routine clinical interpretation. For 12 sets of patient data, SPECT images reconstructed using the experimental algorithm were interpreted separately and compared with interpretation of

  15. Progress in SPECT/CT imaging of prostate cancer.

    PubMed

    Seo, Youngho; Franc, Benjamin L; Hawkins, Randall A; Wong, Kenneth H; Hasegawa, Bruce H

    2006-08-01

    Prostate cancer is the most common type of cancer (other than skin cancer) among men in the United States. Although prostate cancer is one of the few cancers that grow so slowly that it may never threaten the lives of some patients, it can be lethal once metastasized. Indium-111 capromab pendetide (ProstaScint, Cytogen Corporation, Princeton, NJ) imaging is indicated for staging and recurrence detection of the disease, and is particularly useful to determine whether or not the disease has spread to distant metastatic sites. However, the interpretation of 111In-capromab pendetide is challenging without correlated structural information mostly because the radiopharmaceutical demonstrates nonspecific uptake in the normal vasculature, bowel, bone marrow, and the prostate gland. We developed an improved method of imaging and localizing 111In-Capromab pendetide using a SPECT/CT imaging system. The specific goals included: i) development and application of a novel iterative SPECT reconstruction algorithm that utilizes a priori information from coregistered CT; and ii) assessment of clinical impact of adding SPECT/CT for prostate cancer imaging with capromab pendetide utilizing the standard and novel reconstruction techniques. Patient imaging studies with capromab pendetide were performed from 1999 to 2004 using two different SPECT/CT scanners, a prototype SPECT/CT system and a commercial SPECT/CT system (Discovery VH, GE Healthcare, Waukesha, WI). SPECT projection data from both systems were reconstructed using an experimental iterative algorithm that compensates for both photon attenuation and collimator blurring. In addition, the data obtained from the commercial system were reconstructed with attenuation correction using an OSEM reconstruction supplied by the camera manufacturer for routine clinical interpretation. For 12 sets of patient data, SPECT images reconstructed using the experimental algorithm were interpreted separately and compared with interpretation of

  16. Utility of the SPECT Tc-99m labeled RBC blood pool scan in the detection of hepatic hemangiomas

    SciTech Connect

    Guze, B.H.; Hawkins, R.A.

    1989-11-01

    The sensitivity of SPECT imaging of hepatic blood pool activity using Tc-99m labeled RBCs was contrasted with magnetic resonance and CT imaging in 22 cases. SPECT is a noninvasive technique with a high sensitivity for the diagnosis of hepatic hemangiomas. It is helpful for clarifying equivocal magnetic resonance imaging results.

  17. Monte Carlo simulation of PET and SPECT imaging of {sup 90}Y

    SciTech Connect

    Takahashi, Akihiko Sasaki, Masayuki; Himuro, Kazuhiko; Yamashita, Yasuo; Komiya, Isao; Baba, Shingo

    2015-04-15

    Purpose: Yittrium-90 ({sup 90}Y) is traditionally thought of as a pure beta emitter, and is used in targeted radionuclide therapy, with imaging performed using bremsstrahlung single-photon emission computed tomography (SPECT). However, because {sup 90}Y also emits positrons through internal pair production with a very small branching ratio, positron emission tomography (PET) imaging is also available. Because of the insufficient image quality of {sup 90}Y bremsstrahlung SPECT, PET imaging has been suggested as an alternative. In this paper, the authors present the Monte Carlo-based simulation–reconstruction framework for {sup 90}Y to comprehensively analyze the PET and SPECT imaging techniques and to quantitatively consider the disadvantages associated with them. Methods: Our PET and SPECT simulation modules were developed using Monte Carlo simulation of Electrons and Photons (MCEP), developed by Dr. S. Uehara. PET code (MCEP-PET) generates a sinogram, and reconstructs the tomography image using a time-of-flight ordered subset expectation maximization (TOF-OSEM) algorithm with attenuation compensation. To evaluate MCEP-PET, simulated results of {sup 18}F PET imaging were compared with the experimental results. The results confirmed that MCEP-PET can simulate the experimental results very well. The SPECT code (MCEP-SPECT) models the collimator and NaI detector system, and generates the projection images and projection data. To save the computational time, the authors adopt the prerecorded {sup 90}Y bremsstrahlung photon data calculated by MCEP. The projection data are also reconstructed using the OSEM algorithm. The authors simulated PET and SPECT images of a water phantom containing six hot spheres filled with different concentrations of {sup 90}Y without background activity. The amount of activity was 163 MBq, with an acquisition time of 40 min. Results: The simulated {sup 90}Y-PET image accurately simulated the experimental results. PET image is visually

  18. SPECT imaging with resolution recovery

    SciTech Connect

    Bronnikov, A. V.

    2011-07-01

    Single-photon emission computed tomography (SPECT) is a method of choice for imaging spatial distributions of radioisotopes. Many applications of this method are found in nuclear industry, medicine, and biomedical research. We study mathematical modeling of a micro-SPECT system by using a point-spread function (PSF) and implement an OSEM-based iterative algorithm for image reconstruction with resolution recovery. Unlike other known implementations of the OSEM algorithm, we apply en efficient computation scheme based on a useful approximation of the PSF, which ensures relatively fast computations. The proposed approach can be applied with the data acquired with any type of collimators, including parallel-beam fan-beam, cone-beam and pinhole collimators. Experimental results obtained with a micro SPECT system demonstrate high efficiency of resolution recovery. (authors)

  19. A SPECT Camera for Combined MRI and SPECT for Small Animals.

    PubMed

    Meier, D; Wagenaar, D J; Chen, S; Xu, J; Yu, J; Tsui, B M W

    2011-10-01

    We describe an MR-compatible SPECT camera for small animals. The SPECT camera system can be inserted into the bore of a state-of-the-art MRI system and allows researchers to acquire tomographic images from a mouse in-vivo with the MRI and the SPECT acquiring simultaneously. The SPECT system provides functional information, while MRI provides anatomical information. Until today it was impossible to operate conventional SPECT inside the MRI because of mutual interference. The new SPECT technology is based on semiconductor radiation sensors (CZT, ASICs), and it fits into conventional high field MRI systems with a minimum 12-cm bore size. The SPECT camera has an MR-compatible multi-pinhole collimator for mice with a ø25-mm field-of-view. For the work reported here we assembled a prototype SPECT camera system and acquired SPECT and MRI data from radioactive sources and resolution phantoms using the camera outside and inside the MRI.

  20. Measuring astatine-211 distributions with SPECT.

    PubMed

    Turkington, T G; Zalutsky, M R; Jaszczak, R J; Garg, P K; Vaidyanathan, G; Coleman, R E

    1993-08-01

    We have investigated standard SPECT techniques (rotating gamma cameras, multi-hole collimators, and filtered backprojection reconstruction) for imaging astatine-211 distributions. Since 211At emits alpha particles, this nuclide has potential for use in radiotherapy. The capability of imaging this nuclide would allow in vivo evaluation of the distribution and stability of potential 211At-labelled radiotherapeutic agents. 211At decay yields x-rays in the 77-92 keV range in addition to 500-900 keV gamma rays. This study evaluates the feasibility of SPECT imaging using the x-ray emissions of 211At. We have evaluated several collimators, with the determination that the medium-energy collimators we used are suitable, with 7% penetration (uncollimated counts versus collimated counts). Several phantoms were imaged and attenuation coefficients were measured (narrow-beam mu = 0.182 cm-1 for 77-80 keV x-rays in water). Reconstructed images demonstrate qualitative capabilities and a simple quantitative study demonstrates good correction for attenuation and scatter (approximately 10% error), at low count densities, at least for the phantom geometries used in this study.

  1. Three modality image registration of brain SPECT/CT and MR images for quantitative analysis of dopamine transporter imaging

    NASA Astrophysics Data System (ADS)

    Yamaguchi, Yuzuho; Takeda, Yuta; Hara, Takeshi; Zhou, Xiangrong; Matsusako, Masaki; Tanaka, Yuki; Hosoya, Kazuhiko; Nihei, Tsutomu; Katafuchi, Tetsuro; Fujita, Hiroshi

    2016-03-01

    Important features in Parkinson's disease (PD) are degenerations and losses of dopamine neurons in corpus striatum. 123I-FP-CIT can visualize activities of the dopamine neurons. The activity radio of background to corpus striatum is used for diagnosis of PD and Dementia with Lewy Bodies (DLB). The specific activity can be observed in the corpus striatum on SPECT images, but the location and the shape of the corpus striatum on SPECT images only are often lost because of the low uptake. In contrast, MR images can visualize the locations of the corpus striatum. The purpose of this study was to realize a quantitative image analysis for the SPECT images by using image registration technique with brain MR images that can determine the region of corpus striatum. In this study, the image fusion technique was used to fuse SPECT and MR images by intervening CT image taken by SPECT/CT. The mutual information (MI) for image registration between CT and MR images was used for the registration. Six SPECT/CT and four MR scans of phantom materials are taken by changing the direction. As the results of the image registrations, 16 of 24 combinations were registered within 1.3mm. By applying the approach to 32 clinical SPECT/CT and MR cases, all of the cases were registered within 0.86mm. In conclusions, our registration method has a potential in superimposing MR images on SPECT images.

  2. Molecular Imaging of Conscious, Unrestrained Mice with AwakeSPECT

    SciTech Connect

    Baba, Justin S.; Endres, Christopher J.; Foss, Catherine A.; Nimmagadda, Sridhar; Jung, Hyeyun; Goddard, James S.; Lee, Seung Joon; McKisson, John; Smith, Mark F.; Stolin, Alexander V.; Weisenberger, Andrew G.; Pomper, Martin G.

    2013-06-01

    We have developed a SPECT imaging system, AwakeSPECT, to enable molecular brain imaging of untrained mice that are conscious, unanesthetized, and unrestrained. We accomplished this with head tracking and motion correction techniques. Methods: The capability of the system for motion-corrected imaging was demonstrated with a ^99mTc-pertechnetate phantom, ^99mTc-methylene diphosphonate bone imaging, and measurement of the binding potential of the dopamine transporter radioligand ^123I-ioflupane in mouse brain in the awake and anesthetized (isoflurane) states. Stress induced by imaging in the awake state was assessed through measurement of plasma corticosterone levels. Results: AwakeSPECT provided high-resolution bone images reminiscent of those obtained from CT. The binding potential of ^123I-ioflupane in the awake state was on the order of 50% of that obtained with the animal under anesthesia, consistent with previous studies in nonhuman primates. Levels of stress induced were on the order of those seen in other behavioral tasks and imaging studies of awake animals. Conclusion: These results demonstrate the feasibility of SPECT molecular brain imaging of mice in the conscious, unrestrained state and demonstrate the effects of isoflurane anesthesia on radiotracer uptake.

  3. Molecular Imaging of Conscious, Unrestrained Mice with AwakeSPECT

    SciTech Connect

    Baba, Justin S; Endres, Christopher; Foss, Catherine; Nimmagadda, Sridhar; Jung, Hyeyun; Goddard Jr, James Samuel; Lee, Seung Joon; McKisson, John; Smith, Mark F.; Stolin, Alexander; Weisenberger, Andrew G.; Pomper, Martin

    2013-01-01

    We have developed a SPECT imaging system, AwakeSPECT, to enable molecular brain imaging of untrained mice that are conscious, unanesthetized, and unrestrained. We accomplished this with head tracking and motion correction techniques. Methods: The capability of the system for motion-corrected imaging was demonstrated with a 99mTc-pertechnetate phantom, 99mTcmethylene diphosphonate bone imaging, and measurement of the binding potential of the dopamine transporter radioligand 123I-ioflupane in mouse brain in the awake and anesthetized (isoflurane) states. Stress induced by imaging in the awake state was assessed through measurement of plasma corticosterone levels. Results: AwakeSPECT provided high-resolution bone images reminiscent of those obtained from CT. The binding potential of 123I-ioflupane in the awake state was on the order of 50% of that obtained with the animal under anesthesia, consistent with previous studies in nonhuman primates. Levels of stress induced were on the order of those seen in other behavioral tasks and imaging studies of awake animals. Conclusion: These results demonstrate the feasibility of SPECT molecular brain imaging of mice in the conscious, unrestrained state and demonstrate the effects of isoflurane anesthesia on radiotracer uptake.

  4. Detection of Sentinel Lymph Nodes in Gynecologic Tumours by Planar Scintigraphy and SPECT/CT

    PubMed Central

    Kraft, Otakar; Havel, Martin

    2012-01-01

    Objective: Assess the role of planar lymphoscintigraphy and fusion imaging of SPECT/CT in sentinel lymph node (SLN) detection in patients with gynecologic tumours. Material and Methods: Planar scintigraphy and hybrid modality SPECT/CT were performed in 64 consecutive women with gynecologic tumours (mean age 53.6 with range 30-77 years): 36 pts with cervical cancer (Group A), 21 pts with endometrial cancer (Group B), 7 pts with vulvar carcinoma (Group C). Planar and SPECT/CT images were interpreted separately by two nuclear medicine physicians. Efficacy of these two techniques to image SLN were compared. Results: Planar scintigraphy did not image SLN in 7 patients (10.9%), SPECT/CT was negative in 4 patients (6.3%). In 35 (54.7%) patients the number of SLNs captured on SPECT/CT was higher than on planar imaging. Differences in detection of SLN between planar and SPECT/CT imaging in the group of all 64 patients are statistically significant (p<0.05). Three foci of uptake (1.7% from totally visible 177 foci on planar images) in 2 patients interpreted on planar images as hot LNs were found to be false positive non-nodal sites of uptake when further assessed on SPECT/CT. SPECT/CT showed the exact anatomical location of all visualised sentinel nodes. Conclusion: In some patients with gynecologic cancers SPECT/CT improves detection of sentinel lymph nodes. It can image nodes not visible on planar scintigrams, exclude false positive uptake and exactly localise pelvic and paraaortal SLNs. It improves anatomic localization of SLNs. Conflict of interest:None declared. PMID:23486989

  5. Iterative restoration of SPECT projection images

    SciTech Connect

    Glick, S.J.; Xia, W.

    1997-04-01

    Photon attenuation and the limited nonstationary spatial resolution of the detector can reduce both qualitative and quantitative image quality in single photon emission computed tomography (SPECT). In this paper, a reconstruction approach is described which can compensate for both of these degradations. The approach involves processing the project data with Bellini`s method for attenuation compensation followed by an iterative deconvolution technique which uses the frequency distance principle (FDP) to model the distance-dependent camera blur. Modeling of the camera blur with the FDP allows an efficient implementation using fast Fourier transformation (FFT) methods. After processing of the project data, reconstruction is performed using filtered backprojections. Simulation studies using two different brain phantoms show that this approach gives reconstructions with a favorable bias versus noise tradeoff, provides no visually undesirable noise artifacts, and requires a low computational load.

  6. Cervical SPECT Camera for Parathyroid Imaging

    SciTech Connect

    None, None

    2012-08-31

    Primary hyperparathyroidism characterized by one or more enlarged parathyroid glands has become one of the most common endocrine diseases in the world affecting about 1 per 1000 in the United States. Standard treatment is highly invasive exploratory neck surgery called Parathyroidectomy. The surgery has a notable mortality rate because of the close proximity to vital structures. The move to minimally invasive parathyroidectomy is hampered by the lack of high resolution pre-surgical imaging techniques that can accurately localize the parathyroid with respect to surrounding structures. We propose to develop a dedicated ultra-high resolution (~ 1 mm) and high sensitivity (10x conventional camera) cervical scintigraphic imaging device. It will be based on a multiple pinhole-camera SPECT system comprising a novel solid state CZT detector that offers the required performance. The overall system will be configured to fit around the neck and comfortably image a patient.

  7. Physiological imaging with PET and SPECT in Dementia

    SciTech Connect

    Jagust, W.J. . Dept. of Neurology Lawrence Berkeley Lab., CA )

    1989-10-01

    Dementia is a medical problem of increasingly obvious importance. The most common cause of dementia, Alzheimer's disease (AD) accounts for at least 50% of all cases of dementia, with multi-infarct dementia the next most common cause of the syndrome. While the accuracy of diagnosis of AD may range from 80 to 90%, there is currently no laboratory test to confirm the diagnosis. Functional imaging techniques such as positron emission tomography (PET) and single photon emission computed tomography (SPECT) offer diagnostic advantages since brain function is unequivocally disturbed in all dementing illnesses. Both PET and SPECT have been utilized in the study of dementia. While both techniques rely on principles of emission tomography to produce three dimensional maps of injected radiotracers, the differences between positron and single photon emission have important consequences for the practical applications of the two procedures. This briefly reviews the technical differences between PET and SPECT, and discusses how both techniques have been used in our laboratory to elucidate the pathophysiology of dementia. 32 refs., 2 figs.

  8. Organ volume estimation using SPECT

    SciTech Connect

    Zaidi, H.

    1996-06-01

    Knowledge of in vivo thyroid volume has both diagnostic and therapeutic importance and could lead to a more precise quantification of absolute activity contained in the thyroid gland. In order to improve single-photon emission computed tomography (SPECT) quantitation, attenuation correction was performed according to Chang`s algorithm. The dual window method was used for scatter subtraction. The author used a Monte Carlo simulation of the SPECT system to accurately determine the scatter multiplier factor k. Volume estimation using SPECT was performed by summing up the volume elements (voxels) lying within the contour of the object, determined by a fixed threshold and the gray level histogram (GLH) method. Thyroid phantom and patient studies were performed and the influence of (1) fixed thresholding, (2) automatic thresholding, (3) attenuation, (4) scatter, and (5) reconstruction filter were investigated. This study shows that accurate volume estimation of the thyroid gland is feasible when accurate corrections are performed. The relative error is within 7% for the GLH method combined with attenuation and scatter corrections.

  9. SPECT reconstruction with nonuniform attenuation from highly under-sampled projection data

    NASA Astrophysics Data System (ADS)

    Li, Cuifen; Wen, Junhai; Zhang, Kangping; Shi, Donghao; Dong, Haixiang; Li, Wenxiao; Liang, Zhengrong

    2012-03-01

    Single photon emission computed tomography (SPECT) is an important nuclear medicine imaging technique and has been using in clinical diagnoses. The SPECT image can reflect not only organizational structure but also functional activities of human body, therefore diseases can be found much earlier. In SPECT, the reconstruction is based on the measurement of gamma photons emitted by the radiotracer. The number of gamma photons detected is proportional to the dose of radiopharmaceutical, but the dose is limited because of patient safety. There is an upper limit in the number of gamma photons that can be detected per unit time, so it takes a long time to acquire SPECT projection data. Sometimes we just can obtain highly under-sampled projection data because of the limit of the scanning time or imaging hardware. How to reconstruct an image using highly under-sampled projection data is an interesting problem. One method is to minimize the total variation (TV) of the reconstructed image during the iterative reconstruction. In this work, we developed an OSEM-TV SPECT reconstruction algorithm, which could reconstruct the image from highly under-sampled projection data with non-uniform attenuation. Simulation results demonstrate that the OSEM-TV algorithm performs well in SPECT reconstruction with non-uniform attenuation.

  10. Single photon emission photography/magnetic resonance imaging (SPECT/MRI) visualization for frontal-lobe-damaged regions

    NASA Astrophysics Data System (ADS)

    Stokking, Rik; Zuiderveld, Karel J.; Hulshoff Pol, Hilleke E.; Viergever, Max A.

    1994-09-01

    We present multi-modality visualization strategies to convey information contained in registered Single Photon Emission Photography (SPECT) and Magnetic Resonance (MR) images of the brain. Multi-modality visualization provides a means to retrieve valuable information from the data which might otherwise remain obscured. Here we use MRI as an anatomical framework for functional information acquired with SPECT. This is part of clinical research studying the change of functionality caused by a frontal lobe damaged region. A number of known and newly developed techniques for the integrated visualization of SPECT and MR images will be discussed.

  11. Added Value of SPECT/CT in the Evaluation of Benign Bone Diseases of the Appendicular Skeleton.

    PubMed

    Abikhzer, Gad; Srour, Saher; Keidar, Zohar; Bar-Shalom, Rachel; Kagna, Olga; Israel, Ora; Militianu, Daniela

    2016-04-01

    Bone scintigraphy is a sensitive technique to detect altered bone mineralization but has limited specificity. The use of SPECT/CT has improved significantly the diagnostic accuracy of bone scintigraphy, in patients with cancer as well as in evaluation of benign bone disease. It provides precise localization and characterization of tracer-avid foci, shortens the diagnostic workup, and decreases patient anxiety. Through both the SPECT and the CT components, SPECT/CT has an incremental value in characterizing benign bone lesions, specifically in the appendicular skeleton, as illustrated by present case series.

  12. C-SPECT - a Clinical Cardiac SPECT/Tct Platform: Design Concepts and Performance Potential

    PubMed Central

    Chang, Wei; Ordonez, Caesar E.; Liang, Haoning; Li, Yusheng; Liu, Jingai

    2013-01-01

    Because of scarcity of photons emitted from the heart, clinical cardiac SPECT imaging is mainly limited by photon statistics. The sub-optimal detection efficiency of current SPECT systems not only limits the quality of clinical cardiac SPECT imaging but also makes more advanced potential applications difficult to be realized. We propose a high-performance system platform - C-SPECT, which has its sampling geometry optimized for detection of emitted photons in quality and quantity. The C-SPECT has a stationary C-shaped gantry that surrounds the left-front side of a patient’s thorax. The stationary C-shaped collimator and detector systems in the gantry provide effective and efficient detection and sampling of photon emission. For cardiac imaging, the C-SPECT platform could achieve 2 to 4 times the system geometric efficiency of conventional SPECT systems at the same sampling resolution. This platform also includes an integrated transmission CT for attenuation correction. The ability of C-SPECT systems to perform sequential high-quality emission and transmission imaging could bring cost-effective high-performance to clinical imaging. In addition, a C-SPECT system could provide high detection efficiency to accommodate fast acquisition rate for gated and dynamic cardiac imaging. This paper describes the design concepts and performance potential of C-SPECT, and illustrates how these concepts can be implemented in a basic system. PMID:23885129

  13. A review of small animal imaging planar and pinhole spect Gamma camera imaging.

    PubMed

    Peremans, Kathelijne; Cornelissen, Bart; Van Den Bossche, Bieke; Audenaert, Kurt; Van de Wiele, Christophe

    2005-01-01

    Scintigraphy (positron emission tomography (PET) or single photon emission computed tomography (SPECT) techniques) allows qualitative and quantitative measurement of physiologic processes as well as alterations secondary to various disease states. With the use of specific radioligands, molecular pathways and pharmaco-kinetic processes can be investigated. Radioligand delivery can be (semi)quantified in the region of interest in cross-sectional and longitudinal examinations, which can be performed under the same conditions or after physiologic or pharmacologic interventions. Most preclinical pharmacokinetic studies on physiological and experimentally altered physiological processes are performed in laboratory animals using high-resolution imaging systems. Single photon emission imaging has the disadvantage of decreased spatial and temporal resolution compared with PET. The advantage of SPECT is that equipment is generally more accessible and commonly used radionuclides have a longer physical half-life allowing for investigations over a longer time interval. This review will focus on single photon emission scintigraphy. An overview of contemporary techniques to measure biodistribution and kinetics of radiopharmaceuticals in small animal in vivo is presented. Theoretical as well as practical aspects of planar gamma camera and SPECT pinhole (PH) imaging are discussed. Current research is focusing on refining PH SPECT methodology, so specific regarding technical aspects and applications of PH SPECT will be reviewed.

  14. SPECT reconstruction on the GPU

    NASA Astrophysics Data System (ADS)

    Vetter, Christoph; Westermann, Rüdiger

    2008-03-01

    With the increasing reliance of doctors on imaging procedures, not only visualization needs to be optimized, but the reconstruction of the volumes from the scanner output is another bottleneck. Accelerating the computationally intensive reconstruction process improves the medical work flow, matches the reconstruction speed to the acquisition speed, and allows fast batch processing and interactive or near-interactive parameter tuning. Recently, much effort has been focused on using the computational power of graphics processing units (GPUs) for general purpose computations. This paper presents a GPU-accelerated implementation of single photon emission computed tomography (SPECT) reconstruction based on an ordered-subset expectation maximization algorithm. The algorithm uses models for the point-spread-function (PSF) to improve spatial resolution in the reconstruction images. Instead of computing the PSF directly, it is modeled as efficient blurring of slabs on the GPU in order to accelerate the process. The algorithm for the calculation of accumulated attenuation factors that allows correcting the generated volume according to the attenuation properties of the volume is optimized for processing on the GPU. Since these factors can be reused between different iterations, a cache is used that is adapted to different sizes of the video memory so that only those factors have to be recomputed that do not fit onto graphics memory. These improvements make the reconstruction of typical SPECT volume near interactive.

  15. Integration of AdaptiSPECT, a small-animal adaptive SPECT imaging system

    PubMed Central

    Chaix, Cécile; Kovalsky, Stephen; Kosmider, Matthew; Barrett, Harrison H.; Furenlid, Lars R.

    2015-01-01

    AdaptiSPECT is a pre-clinical adaptive SPECT imaging system under final development at the Center for Gamma-ray Imaging. The system incorporates multiple adaptive features: an adaptive aperture, 16 detectors mounted on translational stages, and the ability to switch between a non-multiplexed and a multiplexed imaging configuration. In this paper, we review the design of AdaptiSPECT and its adaptive features. We then describe the on-going integration of the imaging system. PMID:26347197

  16. Brain SPECT and transcranial Doppler (TCD) evaluation of the effects of intra-arterial papaverine for cerebral vasospasm

    SciTech Connect

    Lewis, D.H.; Newell, D.W.; Eskridge, J.M.

    1994-05-01

    Cerebral vasospasm (cv) is a common and serious consequence of subarachnoid hemorrhage. Interventional neuroradiologic techniques for treating cv refractory to medical and hemodynamic measures have included transluminal microballoon angioplasty and intra-arterial papaverine infusion (pap). Eight patients (pts) who had symptomatic cv but were not candidates for microballoon angioplasty received pap via arterial catheter. All 8 pts had brain SPECT with Tc-99m HMPAO and 7 had TCD readings before and after treatment. One pt had 2 separate treatments. Total treatments = 9. Results: Of the total of 9 treatments: 5 demonstrated marked improvement in regional cerebral blood flow on SPECT in the vascular territories that were ischemic, 3 showed mild to moderate improvement of blood flow, and 1 was unchanged. The pt that did not improve on SPECT died due to cardiorespiratory problems but remained comatose without neurologic improvement after the treatment. The other 8 had either prompt clinical improvement or modestly delayed improvement due to concomitant hydrocephalus. infection, recurrent vasospasm or other intervening medical problems. TCD readings in the treated vessels showed improved (lower) velocities that agreed with SPECT improvement after 4 intra-arterial pap treatments. There were 4 discrepancies of SPECT and TCD: 1 with rising TCD velocity in the mild cv range in the treated vessel that demonstrated SPECT improvement; 1 with unchanged velocity in the moderate cv range that showed SPECT improvement; 1 that showed lower velocity in the moderate cv range while the SPECT was unchanged; and 1 that had normal TCD velocities before and after treatment but high pulsatility indices on Doppler (which are characteristic of either elevated intra-cranial pressure or distal vessel disease) who had mild to moderate improvement of blood flow on SPECT after treatment.

  17. SPECT Imaging: Basics and New Trends

    NASA Astrophysics Data System (ADS)

    Hutton, Brian F.

    Single Photon Emission Computed Tomography (SPECT) is widely used as a means of imaging the distribution of administered radiotracers that have single-photon emission. The most widely used SPECT systems are based on the Anger gamma camera, usually involving dual detectors that rotate around the patient. Several factors affect the quality of SPECT images (e.g., resolution and noise) and the ability to perform absolute quantification (e.g., attenuation, scatter, motion, and resolution). There is a trend to introduce dual-modality systems and organ-specific systems, both developments that enhance diagnostic capability.

  18. [Acceptance check and quality control of SPECT].

    PubMed

    Sun, L M; Liu, C B

    2001-05-01

    This paper explains the testing of SPECT, especially the new SPECT with double digital detector and spiral scanning frames that has been introduced to China recently, in the acceptance check, proceeding from the physical functions of the system to its mechanical functions, to the NEMA standard functions, and then to the computer hardware specified in the contract. A brief introduction is also given of the quality control of SPECT in terms of its spatial resolution, energy resolution, spatial linearity, sensitivity, and center of rotation. PMID:12583289

  19. New AIRS: The medical imaging software for segmentation and registration of elastic organs in SPECT/CT

    NASA Astrophysics Data System (ADS)

    Widita, R.; Kurniadi, R.; Darma, Y.; Perkasa, Y. S.; Trianti, N.

    2012-06-01

    We have been successfully improved our software, Automated Image Registration and Segmentation (AIRS), to fuse the CT and SPECT images of elastic organs. Segmentation and registration of elastic organs presents many challenges. Many artifacts can arise in SPECT/CT scans. Also, different organs and tissues have very similar gray levels, which consign thresholding to limited utility. We have been developed a new software to solve different registration and segmentation problems that arises in tomographic data sets. It will be demonstrated that the information obtained by SPECT/CT is more accurate in evaluating patients/objects than that obtained from either SPECT or CT alone. We used multi-modality registration which is amenable for images produced by different modalities and having unclear boundaries between tissues. The segmentation components used in this software is region growing algorithms which have proven to be an effective approach for image segmentation. Our method is designed to perform with clinically acceptable speed, using accelerated techniques (multiresolution).

  20. SPECT assay of radiolabeled monoclonal antibodies

    SciTech Connect

    Jaszczak, R.J.

    1992-02-01

    The long-term goal of this research project is to develop methods to improve the utility of single photon emission computed tomography (SPECI) to quantify the biodistribution of monoclonal antibodies (MoAbs) labeled with clinically relevant radionuclides ({sup 123}I, {sup 131}I, and {sup 111}In) and with another radionuclide,{sup 211}At, recently used in therapy. We describe here our progress in developing quantitative SPECT methodology for {sup 111}In and {sup 123}I. We have focused our recent research thrusts on the following aspects of SPECT: (1) The development of improved SPECT hardware, such as improved acquisition geometries. (2) The development of better reconstruction methods that provide accurate compensation for the physical factors that affect SPECT quantification. (3) The application of carefully designed simulations and experiments to validate our hardware and software approaches.

  1. Single Photon Emission Computed Tomography (SPECT)

    MedlinePlus

    ... High Blood Pressure Tools & Resources Stroke More Single Photon Emission Computed Tomography (SPECT) Updated:Sep 11,2015 ... Persantine) or dobutamine. The tests may take between 2 and 2 1/2 hours. What happens after ...

  2. Cerebral SPECT imaging: Impact on clinical management

    SciTech Connect

    Bloom, M.; Jacobs, S.; Pozniakof, T.

    1994-05-01

    Although cerebral SPECT has been reported to be of value in a variety of neurologic disorders, there is limited data available on the value of SPECT relative to clinical management decisions. The purpose of this study was to determine the effect of cerebral SPECT imaging on patient management. A total of 94 consecutive patients referred for clinical evaluation with brain SPECT were included in this study. Patients were assigned to one of nine groups depending on the clinical indication for the study. These groups included transient ischemia (16), stroke (20), dementia (18), seizures (5), hemorrhage (13), head trauma (6), arteriovenous malformations (6), encephalopathy (6) and a miscellaneous (4) group. All patients were injected with 99mTc HMPAO in doses ranging from 15 mCi to 22 mCi (555 MBq to 814 MBq) and scanned on a triple headed SPECT gamma camera. Two weeks after completion of the study, a standardized interview was conducted between the nuclear and referring physicians to determine if the SPECT findings contributed to an alteration in patient management. Overall, patient management was significantly altered in 47% of the cases referred. The greatest impact on patient management occurred in the group evaluated for transient ischemia, where a total of 13/16 (81%) of patients had their clinical management altered as a result of the cerebral SPECT findings. Clinical management was altered in 61% of patients referred for evaluation of dementia, 67% of patients evaluated for arteriovenous malformations, and 50% of patients with head trauma. In the remainder of the patients, alteration in clinical management ranged from 17% to 50% of patients. This study demonstrates the clinical utility of cerebral SPECT imaging since in a significant number of cases clinical management was altered as a result of the examination. Long term follow up will be necessary to determine patient outcome.

  3. Brain SPECT quantitation in clinical diagnosis

    SciTech Connect

    Hellman, R.S.

    1991-12-31

    Methods to quantitate SPECT data for clinical diagnosis should be chosen so that they take advantage of the lessons learned from PET data. This is particularly important because current SPECT high-resolution brain imaging systems now produce images that are similar in resolution to those generated by the last generation PET equipment (9 mm FWHM). These high-resolution SPECT systems make quantitation of SPECT more problematic than earlier. Methodology validated on low-resolution SPECT systems may no longer be valid for data obtained with the newer SPECT systems. For example, in patients with dementia, the ratio of parietal to cerebellar activity often was studied. However, with new instruments, the cerebellum appears very different: discrete regions are more apparent. The large cerebellar regions usually used with older instrumentation are of an inappropriate size for the new equipment. The normal range for any method of quantitation determined using older equipment probably changes for data obtained with new equipment. It is not surprising that Kim et al. in their simulations demonstrated that because of the finite resolution of imaging systems, the ability to measure pure function is limited, with {open_quotes}anatomy{close_quotes} and {open_quotes}function{close_quotes} coupled in a {open_quotes}complex nonlinear way{close_quotes}. 11 refs.

  4. SPECT assay of radiolabeled monoclonal antibodies

    SciTech Connect

    Jaszczak, R.J.

    1992-02-01

    The accurate determination of the biodistribution of radiolabeled monoclonal antibodies (MoAbs) is important for calculation of dosimetry and evaluation of pharmacokinetic variables such as antibody dose and route of administration. The hypothesis of this application is that the biodistribution of radiolabeled monoclonal antibodies (MoAbs) can be quantitatively determined using single photon emission computed tomography (SPECT). The major thrusts during the third year include the continued development and evaluation of improved 3D SPECT acquisition and reconstruction approaches to improve quantitative imaging of radiolabeled monoclonal antibodies (MoAbs), and the implementation and evaluation of algorithms to register serial SPECT image data sets, or to register 3D SPECT images with 3D image data sets acquired from positron emission tomography (PEI) and magnetic resonance images (MRI). The research has involved the investigation of statistical models and iterative reconstruction algorithms that accurately account for the physical characteristics of the SPECT acquisition system. It is our belief that SPECT quantification can be improved by accurately modeling the physical processes such as attenuation, scatter, geometric collimator response, and other factors that affect the measured projection data.

  5. Drug Development in Alzheimer’s Disease: The Contribution of PET and SPECT

    PubMed Central

    Declercq, Lieven D.; Vandenberghe, Rik; Van Laere, Koen; Verbruggen, Alfons; Bormans, Guy

    2016-01-01

    Clinical trials aiming to develop disease-altering drugs for Alzheimer’s disease (AD), a neurodegenerative disorder with devastating consequences, are failing at an alarming rate. Poorly defined inclusion-and outcome criteria, due to a limited amount of objective biomarkers, is one of the major concerns. Non-invasive molecular imaging techniques, positron emission tomography and single photon emission (computed) tomography (PET and SPE(C)T), allow visualization and quantification of a wide variety of (patho)physiological processes and allow early (differential) diagnosis in many disorders. PET and SPECT have the ability to provide biomarkers that permit spatial assessment of pathophysiological molecular changes and therefore objectively evaluate and follow up therapeutic response, especially in the brain. A number of specific PET/SPECT biomarkers used in support of emerging clinical therapies in AD are discussed in this review. PMID:27065872

  6. Development of advanced industrial SPECT system with 12-gonal diverging-collimator.

    PubMed

    Park, Jang Guen; Jung, Sung-Hee; Kim, Jong Bum; Moon, Jinho; Han, Min Cheol; Kim, Chan Hyeong

    2014-07-01

    Industrial single photon emission computed tomography (SPECT) is a promising diagnosis technique to investigate the dynamic behavior of process media. In the present study, a 12-gonal industrial SPECT system was developed using diverging collimators, and its performance was compared with those of hexagonal and 24-gonal systems. Of all of the systems, the 12-gonal type showed the best performance, providing (1) a detection-efficiency map without edge artifacts, (2) the best image resolution, and (3) reconstruction images that correctly furnish multi-source information. Based on the performance of the three different types of configurations, a SPECT system with 12-gonal type configuration was found most suitable for investigating and visualization of flow dynamics in industrial process systems.

  7. Development of advanced industrial SPECT system with 12-gonal diverging-collimator.

    PubMed

    Park, Jang Guen; Jung, Sung-Hee; Kim, Jong Bum; Moon, Jinho; Han, Min Cheol; Kim, Chan Hyeong

    2014-07-01

    Industrial single photon emission computed tomography (SPECT) is a promising diagnosis technique to investigate the dynamic behavior of process media. In the present study, a 12-gonal industrial SPECT system was developed using diverging collimators, and its performance was compared with those of hexagonal and 24-gonal systems. Of all of the systems, the 12-gonal type showed the best performance, providing (1) a detection-efficiency map without edge artifacts, (2) the best image resolution, and (3) reconstruction images that correctly furnish multi-source information. Based on the performance of the three different types of configurations, a SPECT system with 12-gonal type configuration was found most suitable for investigating and visualization of flow dynamics in industrial process systems. PMID:24636865

  8. Image presentation and normal SPECT rCBF

    SciTech Connect

    Devous, M.D. Sr.

    1991-12-31

    The appearance of images of normal regional cerebral blood flow (rCBF) obtained from single photon emission computed tomography (SPECT) is influenced by several factors, including (1) the environmental conditions at the time of administration of the radiotracer, (2) the characteristics of the subject (eg. age, gender, and handedness), (3) the format used for image presentation, (4) the quality of the tomographic device, (5) the choices of image-processing techniques, and (6) the radiopharmaceutical used. The first three of these topics are briefly reviewed here; topics 4, 5 and 6 are reviewed by others in this workshop summary. 27 refs.

  9. A guide to SPECT equipment for brain imaging

    SciTech Connect

    Hoffer, P.B.; Zubal, G.

    1991-12-31

    Single photon emission computed tomography (SPECT) was started by Kuhl and Edwards about 30 years ago. Their original instrument consisted of four focused Nal probes mounted on a moving gantry. During the 1980s, clinical SPECT imaging was most frequently performed using single-headed Anger-type cameras which were modified for rotational as well as static imaging. Such instruments are still available and may be useful in settings where there are few patients and SPECT is used only occasionally. More frequently, however, dedicated SPECT devices are purchased which optimize equipment potential while being user-friendly. Modern SPECT instrumentation incorporates improvements in the detector, computers, mathematical formulations, electronics and display systems. A comprehensive discussion of all aspects of SPECT is beyond the scope of this article. The authors, however, discuss general concepts of SPECT, the current state-of-the-art in clinical SPECT instrumentation, and areas of common misunderstanding. 9 refs.

  10. Objective evaluation of reconstruction methods for quantitative SPECT imaging in the absence of ground truth

    NASA Astrophysics Data System (ADS)

    Jha, Abhinav K.; Song, Na; Caffo, Brian; Frey, Eric C.

    2015-03-01

    Quantitative single-photon emission computed tomography (SPECT) imaging is emerging as an important tool in clinical studies and biomedical research. There is thus a need for optimization and evaluation of systems and algorithms that are being developed for quantitative SPECT imaging. An appropriate objective method to evaluate these systems is by comparing their performance in the end task that is required in quantitative SPECT imaging, such as estimating the mean activity concentration in a volume of interest (VOI) in a patient image. This objective evaluation can be performed if the true value of the estimated parameter is known, i.e. we have a gold standard. However, very rarely is this gold standard known in human studies. Thus, no-gold-standard techniques to optimize and evaluate systems and algorithms in the absence of gold standard are required. In this work, we developed a no-gold-standard technique to objectively evaluate reconstruction methods used in quantitative SPECT when the parameter to be estimated is the mean activity concentration in a VOI. We studied the performance of the technique with realistic simulated image data generated from an object database consisting of five phantom anatomies with all possible combinations of five sets of organ uptakes, where each anatomy consisted of eight different organ VOIs. Results indicate that the method pro- vided accurate ranking of the reconstruction methods. We also demonstrated the application of consistency checks to test the no-gold-standard output.

  11. Performance evaluation of a compact PET/SPECT/CT tri-modality system for small animal imaging applications

    NASA Astrophysics Data System (ADS)

    Wei, Qingyang; Wang, Shi; Ma, Tianyu; Wu, Jing; Liu, Hui; Xu, Tianpeng; Xia, Yan; Fan, Peng; Lyu, Zhenlei; Liu, Yaqiang

    2015-06-01

    PET, SPECT and CT imaging techniques are widely used in preclinical small animal imaging applications. In this paper, we present a compact small animal PET/SPECT/CT tri-modality system. A dual-functional, shared detector design is implemented which enables PET and SPECT imaging with a same LYSO ring detector. A multi-pinhole collimator is mounted on the system and inserted into the detector ring in SPECT imaging mode. A cone-beam CT consisting of a micro focus X-ray tube and a CMOS detector is implemented. The detailed design and the performance evaluations are reported in this paper. In PET imaging mode, the measured NEMA based spatial resolution is 2.12 mm (FWHM), and the sensitivity at the central field of view (CFOV) is 3.2%. The FOV size is 50 mm (∅)×100 mm (L). The SPECT has a spatial resolution of 1.32 mm (FWHM) and an average sensitivity of 0.031% at the center axial, and a 30 mm (∅)×90 mm (L) FOV. The CT spatial resolution is 8.32 lp/mm @10%MTF, and the contrast discrimination function value is 2.06% with 1.5 mm size cubic box object. In conclusion, a compact, tri-modality PET/SPECT/CT system was successfully built with low cost and high performance.

  12. On the Utility of MIBG SPECT/CT in Evaluating Cardiac Sympathetic Dysfunction in Lewy Body Diseases

    PubMed Central

    Odagiri, Hayato; Baba, Toru; Nishio, Yoshiyuki; Iizuka, Osamu; Matsuda, Minoru; Inoue, Kentaro; Kikuchi, Akio; Hasegawa, Takafumi; Aoki, Masashi; Takeda, Atsushi; Taki, Yasuyuki; Mori, Etsuro

    2016-01-01

    Background Abnormal cardiac uptake of 123I-metaiodobenzylguanidine (123I-MIBG) is a diagnostic marker of Lewy body diseases (LBDs), e.g., Parkinson’s disease (PD) and dementia with Lewy bodies (DLB). Planar imaging is generally used to assess cardiac sympathetic dysfunction in 123I-MIBG scintigraphy; however, its clinical utility requires further improvement. We hypothesized that the co-registration of single-photon emission tomography (SPECT) and computed tomography (CT) images would improve the diagnostic accuracy of 123I-MIBG cardiac scintigraphy for LBDs. This study sought to evaluate the effects of SPECT/CT imaging on 123I-MIBG cardiac scintigraphy for diagnosing LBDs. Methods We retrospectively investigated data of 54 patients (consecutive 18 patients in each PD, DLB, and idiopathic normal pressure hydrocephalus [iNPH] groups) who underwent 123I-MIBG cardiac scintigraphy (planar and SPECT/CT) because of suspected LBDs at the Tohoku University hospital from June 2012 to June 2015. We compared the diagnostic accuracies of the conventional planar 123I-MIBG method and SPECT/CT methods (manual and semi-automatic). Results In the conventional planar analysis, 123I-MIBG uptake decreased only in the DLB group compared with the iNPH group. In contrast, the SPECT/CT analysis revealed significantly lower 123I-MIBG uptake in both the PD and DLB groups compared with the iNPH group. Furthermore, a receiver operating characteristic analysis revealed that both the manual and semi-automatic SPECT/CT methods were superior to the conventional planar method in differentiating the 3 disorders. Conclusions SPECT/CT 123I-MIBG cardiac scintigraphy can detect mild cardiac sympathetic dysfunction in LDBs. Our results suggest that the SPECT/CT technique improves diagnostic accuracy for LBDs. PMID:27055151

  13. Adaptive SPECT imaging with crossed-slit apertures

    PubMed Central

    Durko, Heather L.; Furenlid, Lars R.

    2015-01-01

    Preclinical single-photon emission computed tomography (SPECT) is an essential tool for studying the progression, response to treatment, and physiological changes in small animal models of human disease. The wide range of imaging applications is often limited by the static design of many preclinical SPECT systems. We have developed a prototype imaging system that replaces the standard static pinhole aperture with two sets of movable, keel-edged copper-tungsten blades configured as crossed (skewed) slits. These apertures can be positioned independently between the object and detector, producing a continuum of imaging configurations in which the axial and transaxial magnifications are not constrained to be equal. We incorporated a megapixel silicon double-sided strip detector to permit ultrahigh-resolution imaging. We describe the configuration of the adjustable slit aperture imaging system and discuss its application toward adaptive imaging, and reconstruction techniques using an accurate imaging forward model, a novel geometric calibration technique, and a GPU-based ultra-high-resolution reconstruction code. PMID:26190884

  14. Emerging Imaging Techniques

    PubMed Central

    McVeigh, Elliot R.

    2007-01-01

    This article reviews recent developments in selected imaging technologies focused on the cardiovascular system. The techniques covered are: ultrasound biomicroscopy (UBM), microSPECT, microPET, near infrared imaging, and quantum dots. For each technique, the basic physical principles are explained and recent example applications demonstrated. PMID:16614313

  15. Small animal SPECT and its place in the matrix of molecular imaging technologies.

    PubMed

    Meikle, Steven R; Kench, Peter; Kassiou, Michael; Banati, Richard B

    2005-11-21

    Molecular imaging refers to the use of non-invasive imaging techniques to detect signals that originate from molecules, often in the form of an injected tracer, and observe their interaction with a specific cellular target in vivo. Differences in the underlying physical principles of these measurement techniques determine the sensitivity, specificity and length of possible observation of the signal, characteristics that have to be traded off according to the biological question under study. Here, we describe the specific characteristics of single photon emission computed tomography (SPECT) relative to other molecular imaging technologies. SPECT is based on the tracer principle and external radiation detection. It is capable of measuring the biodistribution of minute (<10(-10) molar) concentrations of radio-labelled biomolecules in vivo with sub-millimetre resolution and quantifying the molecular kinetic processes in which they participate. Like some other imaging techniques, SPECT was originally developed for human use and was subsequently adapted for imaging small laboratory animals at high spatial resolution for basic and translational research. Its unique capabilities include (i) the ability to image endogenous ligands such as peptides and antibodies due to the relative ease of labelling these molecules with technetium or iodine, (ii) the ability to measure relatively slow kinetic processes (compared with positron emission tomography, for example) due to the long half-life of the commonly used isotopes and (iii) the ability to probe two or more molecular pathways simultaneously by detecting isotopes with different emission energies. In this paper, we review the technology developments and design tradeoffs that led to the current state-of-the-art in SPECT small animal scanning and describe the position SPECT occupies within the matrix of molecular imaging technologies.

  16. Simultaneous reconstruction and segmentation for dynamic SPECT imaging

    NASA Astrophysics Data System (ADS)

    Burger, Martin; Rossmanith, Carolin; Zhang, Xiaoqun

    2016-10-01

    This work deals with the reconstruction of dynamic images that incorporate characteristic dynamics in certain subregions, as arising for the kinetics of many tracers in emission tomography (SPECT, PET). We make use of a basis function approach for the unknown tracer concentration by assuming that the region of interest can be divided into subregions with spatially constant concentration curves. Applying a regularised variational framework reminiscent of the Chan-Vese model for image segmentation we simultaneously reconstruct both the labelling functions of the subregions as well as the subconcentrations within each region. Our particular focus is on applications in SPECT with the Poisson noise model, resulting in a Kullback-Leibler data fidelity in the variational approach. We present a detailed analysis of the proposed variational model and prove existence of minimisers as well as error estimates. The latter apply to a more general class of problems and generalise existing results in literature since we deal with a nonlinear forward operator and a nonquadratic data fidelity. A computational algorithm based on alternating minimisation and splitting techniques is developed for the solution of the problem and tested on appropriately designed synthetic data sets. For those we compare the results to those of standard EM reconstructions and investigate the effects of Poisson noise in the data.

  17. Frequency weighted least squares reconstruction of truncated transmission SPECT data

    SciTech Connect

    Riddell, C.; Savi, A.; Gilardi, M.C.; Fazio, F.

    1996-08-01

    A least squares technique for reconstructing truncated data is presented. The method involves including the ramp filter into the system matrix. The sinogram is extrapolated with zeros for filtering but extrapolated values are not considered during backward and forward projections.The new matrix leads to a frequency weighted least squares criterion. Tikhonov regularization and a priori information are considered. For the 0-order regularization, the resulting images are biased but it is shown that this bias is recovered by a simple scaling process. First and second order regularizations provide true restoration. The technique is applied to simulated and real transmission SPECT data. Results show that the frequency least squares criterion is a valuable approach for efficiently reconstructing truncated sinograms.

  18. Simultaneous SPECT imaging of multi-targets to assist in identifying hepatic lesions

    PubMed Central

    Guo, Zhide; Gao, Mengna; Zhang, Deliang; Li, Yesen; Song, Manli; Zhuang, Rongqiang; Su, Xinhui; Chen, Guibing; Liu, Ting; Liu, Pingguo; Wu, Hua; Du, Jin; Zhang, Xianzhong

    2016-01-01

    Molecular imaging technique is an attractive tool to detect liver disease at early stage. This study aims to develop a simultaneous dual-isotope single photon emission computed tomography (SPECT)/CT imaging method to assist diagnosis of hepatic tumor and liver fibrosis. Animal models of liver fibrosis and orthotopic human hepatocellular carcinoma (HCC) were established. The tracers of 131I-NGA and 99mTc-3P-RGD2 were selected to target asialoglycoprotein receptor (ASGPR) on the hepatocytes and integrin αvβ3 receptor in tumor or fibrotic liver, respectively. SPECT imaging and biodistribution study were carried out to verify the feasibility and superiority. As expected, 99mTc-3P-RGD2 had the ability to evaluate liver fibrosis and detect tumor lesions. 131I-NGA showed that it was effective in assessing the anatomy and function of the liver. In synchronized dual-isotope SPECT/CT imaging, clear fusion images can be got within 30 minutes for diagnosing liver fibrosis and liver cancer. This new developed imaging approach enables the acquisition of different physiological information for diagnosing liver fibrosis, liver cancer and evaluating residual functional liver volume simultaneously. So synchronized dual-isotope SPECT/CT imaging with 99mTc-3P-RGD2 and 131I-NGA is an effective approach to detect liver disease, especially liver fibrosis and liver cancer. PMID:27377130

  19. Multimodal imaging with hybrid semiconductor detectors Timepix for an experimental MRI-SPECT system

    NASA Astrophysics Data System (ADS)

    Zajicek, J.; Jakubek, J.; Burian, M.; Vobecky, M.; Fauler, A.; Fiederle, M.; Zwerger, A.

    2013-01-01

    An increasing number of clinical applications are being based on multimodal imaging systems (MIS), including anatomical (CT, MRI) and functional (PET, SPECT) techniques to provide complex information in a single image. CT with one of the scintigraphic methods (PET or SPECT) is nowadays a combination of choice for clinical practice and it is mostly used in cardiography and tumour diagnostics. Combination with MRI is also being implemented as no radiation dose is imparted to the patient and it is possible to gain higher structural resolution of soft tissues (brain imaging). A major disadvantage of such systems is inability to operate scintillators with photomultipliers (used for detection of γ rays) in presence of high magnetic fields. In this work we present the application of the semiconductor pixel detector for SPECT method in combination with MR imaging. We propose a novel approach based on MRI compatible setup with CdTe pixel sensor Timepix and non-conductive collimator. Measurements were performed on high proton-density (PD) phantom (1H) with an embedded radioisotopic source inside the shielded RF coil by MRI animal scanner (4.7 T). Our results pave the way for a combined MRI-SPECT system. The project was performed in the framework of the Medipix Collaboration.

  20. Freehand SPECT in low uptake situations

    NASA Astrophysics Data System (ADS)

    Lasser, Tobias; Ziegler, Sibylle I.; Navab, Nassir

    2011-03-01

    3D functional imaging in the operating room can be extremely useful for some procedures like SLN mapping or SLN biopsies. Freehand SPECT is an example of such an imaging modality, combining manually scanned, hand-held 1D gamma detectors with spatial positioning systems in order to reconstruct localized 3D SPECT images, for example in the breast or neck region. Standard series expansion methods are applied together with custom physical models of the acquisition process and custom filtering procedures to perform 3D tomographic reconstruction from sparse, limited-angle and irregularly sampled data. A Freehand SPECT system can easily be assembled on a mobile cart suitable for use in the operating room. This work addresses in particular the problem of objects with low uptake (like sentinel lymph nodes), where reconstruction tends to be difficult due to low signal to noise ratio. In a neck-like phantom study, we show that four simulated nodes of 250 microliter volume with 0.06% respectively 0.03% uptake of a virtual 70MBq injection of Tc99m (the typical activity for SLN procedures at our hospital) in a background of water can be reconstructed successfully using careful filtering procedures in the reconstruction pipeline. Ten independent Freehand SPECT scans of the phantom were performed by several different operators, with an average scan duration of 5.1 minutes. The resulting reconstructions show an average spatial accuracy within voxel dimensions (2.5mm) compared to CT and exhibit correct relative quantification.

  1. Singular Value Decomposition of Pinhole SPECT Systems.

    PubMed

    Palit, Robin; Kupinski, Matthew A; Barrett, Harrison H; Clarkson, Eric W; Aarsvold, John N; Volokh, Lana; Grobshtein, Yariv

    2009-03-12

    A single photon emission computed tomography (SPECT) imaging system can be modeled by a linear operator H that maps from object space to detector pixels in image space. The singular vectors and singular-value spectra of H provide useful tools for assessing system performance. The number of voxels used to discretize object space and the number of collection angles and pixels used to measure image space make the matrix dimensions H large. As a result, H must be stored sparsely which renders several conventional singular value decomposition (SVD) methods impractical. We used an iterative power methods SVD algorithm (Lanczos) designed to operate on very large sparsely stored matrices to calculate the singular vectors and singular-value spectra for two small animal pinhole SPECT imaging systems: FastSPECT II and M(3)R. The FastSPECT II system consisted of two rings of eight scintillation cameras each. The resulting dimensions of H were 68921 voxels by 97344 detector pixels. The M(3)R system is a four camera system that was reconfigured to measure image space using a single scintillation camera. The resulting dimensions of H were 50864 voxels by 6241 detector pixels. In this paper we present results of the SVD of each system and discuss calculation of the measurement and null space for each system.

  2. Multidivergent-beam stationary cardiac SPECT.

    PubMed

    Zeng, Gengsheng L; Stevens, Andrew M

    2009-07-01

    This article develops a stationary cardiac single photon emission computed tomography (SPECT) system using a novel multidivergent-beam collimator. This stationary SPECT system is inexpensive to build, small, and able to acquire true dynamic SPECT data. Stationary cardiac SPECT systems with multipinhole technology already exist. The proposed approach is to replace the multipinhole collimators with the originally designed multidivergent-beam collimators. The motivation for replacing the pinhole technology by divergent-beam technology is based on the following facts. The resolution/sensitivity trade-off for the pinhole is excellent (good resolution and good sensitivity) only in small object (e.g., small animal) imaging when it operates in the image magnifying mode. However, in large object (e.g., human) imaging, the resolution/sensitivity trade-off is poor (poor resolution and poor sensitivity) when the pinhole operates in the image reducing mode. In a stationary system, the number of angular views is limited; thus, image reduction is necessary to obtain more view angles. In this image reducing situation, divergent-beam collimation is able to provide better resolution and detection sensitivity than pinhole collimation. Computer simulations are carried out to verified the claims. PMID:19673185

  3. Tl-201 and Tc-99m-Sestamibi SPECT for brain tumor detection: Comparison using MRI coregistration

    SciTech Connect

    Darcourt, J.; Itti, L.; Chang, L.

    1994-05-01

    Tl-201 (Tl) brain SPECT has been validated for the differential diagnosis of high versus low grade gliomas and recurrence versus radiation necrosis. We compared this technique to Tc-99m-Sestamibi (MIBI) SPECT in 9 patients (pts) with brain tumors using MRI coregistration. Pts were injected with 4 mCi of Tl and brain SPECT was performed using a dedicated brain system. This was immediately following by an injection of 20 mCi of MIBI and a brain SPECT using the same camera and with the pt in the same position. Four pts were studied for the diagnosis of radiation necrosis vs. tumor recurrence (2 had biopsy proven recurrence); 5 pts were studied for primary tumor evaluation: 2 meningiomas, 1 oligodendroglioma, 1 low-grade astrocytoma, 1 cysticercosis. Coregistration was performed for every pt by 3D surface fitting of the inner skull MIBI contour to the MRI brain surface extracted automatically. ROIs were drawn on the MRI and applied to the coregistered MIBI and Tl images for tumor to non-tumor ratios T/NT calculations. There was a tight correlation between MIBI and Tl T/NT (r-0.96) and a 1.5 threshold separated radiation necrosis from recurrence and low from high grade primary tumors. Therefore, the data already available on Tl brain tumor imaging can be used with MIBI SPECT with the advantage of a better image quality (2.5 to 4 times more counts).

  4. MIRD Pamphlet No. 23: Quantitative SPECT for Patient-Specific 3-Dimensional Dosimetry in Internal Radionuclide Therapy

    PubMed Central

    Dewaraja, Yuni K.; Frey, Eric C.; Sgouros, George; Brill, A. Bertrand; Roberson, Peter; Zanzonico, Pat B.; Ljungberg, Michael

    2012-01-01

    In internal radionuclide therapy, a growing interest in voxel-level estimates of tissue-absorbed dose has been driven by the desire to report radiobiologic quantities that account for the biologic consequences of both spatial and temporal nonuniformities in these dose estimates. This report presents an overview of 3-dimensional SPECT methods and requirements for internal dosimetry at both regional and voxel levels. Combined SPECT/CT image-based methods are emphasized, because the CT-derived anatomic information allows one to address multiple technical factors that affect SPECT quantification while facilitating the patient-specific voxel-level dosimetry calculation itself. SPECT imaging and reconstruction techniques for quantification in radionuclide therapy are not necessarily the same as those designed to optimize diagnostic imaging quality. The current overview is intended as an introduction to an upcoming series of MIRD pamphlets with detailed radionuclide-specific recommendations intended to provide best-practice SPECT quantification–based guidance for radionuclide dosimetry. PMID:22743252

  5. High-Efficiency SPECT MPI: Comparison of Automated Quantification, Visual Interpretation, and Coronary Angiography

    PubMed Central

    Duvall, W. Lane; Slomka, Piotr J.; Gerlach, Jim R.; Sweeny, Joseph M.; Baber, Usman; Croft, Lori B.; Guma, Krista A.; George, Titus; Henzlova, Milena J.

    2013-01-01

    Background Recently introduced high-efficiency (HE) SPECT cameras with solid-state CZT detectors have been shown to decrease imaging time and reduce radiation exposure to patients. An automated, computer derived quantification of HE MPI has been shown to correlate well with coronary angiography on one HE SPECT camera system (D-SPECT), but has not been compared to visual interpretation on any of the HE SPECT platforms. Methods Patients undergoing a clinically indicated Tc-99m sestamibi HE SPECT (GE Discovery 530c with supine and prone imaging) study over a one year period followed by a coronary angiogram within 2 months were included. Only patients with a history of CABG surgery were excluded. Both MPI studies and coronary angiograms were reinterpreted by blinded readers. One hundred and twenty two very low (risk of CAD < 5%) or low (risk of CAD < 10%) likelihood subjects with normal myocardial perfusion were used to create normal reference limits. Computer derived quantification of the total perfusion deficit (TPD) at stress and rest was obtained with QPS software. The visual and automated MPI quantification were compared to coronary angiography (≥ 70% luminal stenosis) by receiver operating curve (ROC) analysis. Results Of the 3,111 patients who underwent HE SPECT over a one year period, 160 patients qualified for the correlation study (66% male, 52% with a history of CAD). The ROC area under the curve (AUC) was similar for both the automated and visual interpretations using both supine only and combined supine and prone images (0.69-0.74). Using thresholds determined from sensitivity and specificity curves, the automated reads showed higher specificity (59-67% versus 27-60%) and lower sensitivity (71-72% versus 79-93%) than the visual reads. By including prone images sensitivity decreased slightly but specificity increased for both. By excluding patients with known CAD and cardiomyopathies, AUC and specificity increased for both techniques (0.72-0.82). The use

  6. Assessment of the sources of error affecting the quantitative accuracy of SPECT imaging in small animals

    SciTech Connect

    Joint Graduate Group in Bioengineering, University of California, San Francisco and University of California, Berkeley; Department of Radiology, University of California; Gullberg, Grant T; Hwang, Andrew B.; Franc, Benjamin L.; Gullberg, Grant T.; Hasegawa, Bruce H.

    2008-02-15

    Small animal SPECT imaging systems have multiple potential applications in biomedical research. Whereas SPECT data are commonly interpreted qualitatively in a clinical setting, the ability to accurately quantify measurements will increase the utility of the SPECT data for laboratory measurements involving small animals. In this work, we assess the effect of photon attenuation, scatter and partial volume errors on the quantitative accuracy of small animal SPECT measurements, first with Monte Carlo simulation and then confirmed with experimental measurements. The simulations modeled the imaging geometry of a commercially available small animal SPECT system. We simulated the imaging of a radioactive source within a cylinder of water, and reconstructed the projection data using iterative reconstruction algorithms. The size of the source and the size of the surrounding cylinder were varied to evaluate the effects of photon attenuation and scatter on quantitative accuracy. We found that photon attenuation can reduce the measured concentration of radioactivity in a volume of interest in the center of a rat-sized cylinder of water by up to 50percent when imaging with iodine-125, and up to 25percent when imaging with technetium-99m. When imaging with iodine-125, the scatter-to-primary ratio can reach up to approximately 30percent, and can cause overestimation of the radioactivity concentration when reconstructing data with attenuation correction. We varied the size of the source to evaluate partial volume errors, which we found to be a strong function of the size of the volume of interest and the spatial resolution. These errors can result in large (>50percent) changes in the measured amount of radioactivity. The simulation results were compared with and found to agree with experimental measurements. The inclusion of attenuation correction in the reconstruction algorithm improved quantitative accuracy. We also found that an improvement of the spatial resolution through the

  7. Indium-Labeling of siRNA for Small Animal SPECT Imaging.

    PubMed

    Jones, Steven; Merkel, Olivia

    2016-01-01

    Ever since the discovery of RNA interference (RNAi), therapeutic delivery of siRNA has attracted a lot of interest. However, due to the nature and structure of siRNA, a carrier is needed for any mode of systemic treatment. Furthermore, specific imaging techniques are required to trace where the deposition of the siRNA occurs throughout the body after treatment. Tracking in vivo siRNA biodistribution allows understanding and interpreting therapeutics effects and side effects. A great advantage of noninvasive imaging techniques such as SPECT imaging is that several time points can be assessed in the same subject. Thus, the time course of biodistribution or metabolic processes can be followed. Therefore, we have described an approach to modify siRNA with a DTPA (Diethylene Triamine Pentaacetic Acid) chelator in order to utilize an indium labeled siRNA for SPECT imaging. Here, we explain the details of the labeling and purification procedures.

  8. Small animal imaging with multi-pinhole SPECT.

    PubMed

    Nuyts, Johan; Vunckx, Kathleen; Defrise, Michel; Vanhove, Christian

    2009-06-01

    With Single Photon Emission Computed Tomography (SPECT), images of minute concentrations of tracer molecules can be acquired, allowing in vivo molecular imaging. For human imaging, the SPECT system has a modest spatial resolution of 5-15 mm, a large field of view and a high sensitivity. Using multi-pinhole SPECT, one can trade in field of view for resolution with preserved sensitivity, which enables the implementation of a small animal SPECT system with an improved resolution, currently ranging from 0.3 to 2 mm, in a much smaller field of view. The unconventional collimation and the more stringent resolution requirements pose problems that are not present in clinical SPECT imaging. This paper discusses how these problems can be solved to implement micro-SPECT imaging on a rotating gamma camera.

  9. Systolic and diastolic assessment by 3D-ASM segmentation of gated-SPECT Studies: a comparison with MRI

    NASA Astrophysics Data System (ADS)

    Tobon-Gomez, C.; Bijnens, B. H.; Huguet, M.; Sukno, F.; Moragas, G.; Frangi, A. F.

    2009-02-01

    Gated single photon emission tomography (gSPECT) is a well-established technique used routinely in clinical practice. It can be employed to evaluate global left ventricular (LV) function of a patient. The purpose of this study is to assess LV systolic and diastolic function from gSPECT datasets in comparison with cardiac magnetic resonance imaging (CMR) measurements. This is achieved by applying our recently implemented 3D active shape model (3D-ASM) segmentation approach for gSPECT studies. This methodology allows for generation of 3D LV meshes for all cardiac phases, providing volume time curves and filling rate curves. Both systolic and diastolic functional parameters can be derived from these curves for an assessment of patient condition even at early stages of LV dysfunction. Agreement of functional parameters, with respect to CMR measurements, were analyzed by means of Bland-Altman plots. The analysis included subjects presenting either LV hypertrophy, dilation or myocardial infarction.

  10. The clinical impact of SPECT/PET co-registration with MRI in patients with brain tumors

    SciTech Connect

    Macapinlac, H.A.; Scott, A.M.; Zhang, J.J.

    1994-05-01

    We wanted to evaluate the clinical impact of co-registering SPECT and PET images with MRI (Gd-DTPA) in brain tumor patients. 81 patients with known or suspected brain tumors had 168 SPECT and/or PET scans which were difficult to interpret were coregistered with MRI. A modified Pellizari/Chen surface matching algorithm was used to fit the SPECT/PET and MR images. Impact of the technique on interpretation of the scans was defined as (A) no effect, (B) moderate effect (better localize abnormal uptake to suspected tumor and distinguish normal activity from tumor), (C) basis for final interpretation (distinguish tumor from necrosis, localize biopsy site, find occult tumor, grading of tumor). Impact on patient management was defined as (A) no effect, (B) altered diagnostic/treatment decision (continuation of conservative care, or justify chemo or radiation), (C) basis for treatment (direct biopsy, surgery, and/or radiation).

  11. Technological Development and Advances in SPECT/CT

    PubMed Central

    Seo, Youngho; Aparici, Carina Mari; Hasegawa, Bruce H

    2010-01-01

    SPECT/CT has emerged over the past decade as a means of correlating anatomical information from CT with functional information from SPECT. The integration of SPECT and CT in a single imaging device facilitates anatomical localization of the radiopharmaceutical to differentiate physiological uptake from that associated with disease and patient-specific attenuation correction to improve the visual quality and quantitative accuracy of the SPECT image. The first clinically available SPECT/CT systems performed emission-transmission imaging using a dual-headed SPECT camera and a low-power x-ray CT sub-system. Newer SPECT/CT systems are available with high-power CT sub-systems suitable for detailed anatomical diagnosis, including CT coronary angiography and coronary calcification that can be correlated with myocardial perfusion measurements. The high-performance CT capabilities also offer the potential to improve compensation of partial volume errors for more accurate quantitation of radionuclide measurement of myocardial blood flow and other physiological processes and for radiation dosimetry for radionuclide therapy. In addition, new SPECT technologies are being developed that significantly improve the detection efficiency and spatial resolution for radionuclide imaging of small organs including the heart, brain, and breast, and therefore may provide new capabilities for SPECT/CT imaging in these important clinical applications. PMID:18396178

  12. Imaging Tobacco Smoking with PET and SPECT.

    PubMed

    Cosgrove, Kelly P; Esterlis, Irina; Sandiego, Christine; Petrulli, Ryan; Morris, Evan D

    2015-01-01

    Receptor imaging, including positron emission computed tomography (PET) and single photon emission computed tomography (SPECT), provides a way to measure chemicals of interest, such as receptors, and neurotransmitter fluctuations, in the living human brain. Imaging the neurochemical mechanisms involved in the maintenance and recovery from tobacco smoking has provided insights into critical smoking related brain adaptations. Nicotine, the primary addictive chemical in tobacco smoke, enters the brain, activates beta2-nicotinic acetylcholine receptors (β2*-nAChRs) and, like most drugs of abuse, elicits dopamine (DA) release in the ventral striatum. Both β2*-nAChRs and DA signaling are critical neurosubstrates underlying tobacco smoking behaviors and dependence and have been studied extensively with PET and SPECT brain imaging. We review the imaging literature on these topics and describe how brain imaging has helped inform the treatment of tobacco smoking.

  13. Dopamine transporter SPECT/CT and perfusion brain SPECT imaging in idiopathic basal ganglia calcinosis.

    PubMed

    Paschali, Anna; Lakiotis, Velissarios; Messinis, Lambros; Markaki, Elli; Constantoyannis, Constantine; Ellul, John; Vassilakos, Pavlos

    2009-07-01

    A case of idiopathic basal ganglia calcification in a 56-year-old woman with parkinsonism and cognitive impairment is described. The nigrostriatal dopaminergic pathway and regional cerebral blood flow were evaluated using dopamine transporter (DAT) brain single photon emission tomography combined with a low-dose x-ray computerized tomography transmission (hybrid SPECT/CT) and Tc-99m HMPAO brain perfusion SPECT study, respectively. DAT SPECT/CT imaging revealed a reduction in DAT binding in both striatum regions coinciding with bilateral calcifications in the basal ganglia. Brain perfusion scan showed hypoperfusion in basal ganglia regions, posterior parietal cortex bilaterally, left frontopolar and dorsolateral prefrontal cortex, and left temporal lobe. These findings correlated well with the clinical condition of the patient. Mineralization may play a critical role in the pathogenesis of neuronal degeneration. Cortical perfusion changes in patients may better explain the patient's altered cognitive and motor functions.

  14. Reconstruction of dynamic gated cardiac SPECT

    SciTech Connect

    Jin Mingwu; Yang Yongyi; King, Michael A.

    2006-11-15

    In this paper we propose an image reconstruction procedure which aims to unify gated single photon emission computed tomography (SPECT) and dynamic SPECT into a single method. We divide the cardiac cycle into a number of gate intervals as in gated SPECT, but treat the tracer distribution for each gate as a time-varying signal. By using both dynamic and motion-compensated temporal regularization, our reconstruction procedure will produce an image sequence that shows both cardiac motion and time-varying tracer distribution simultaneously. To demonstrate the proposed reconstruction method, we simulated gated cardiac perfusion imaging using the gated mathematical cardiac-torso (gMCAT) phantom with Tc99m-Teboroxime as the imaging agent. Our results show that the proposed method can produce more accurate reconstruction of gated dynamic images than independent reconstruction of individual gate frames with spatial smoothness alone. In particular, our results show that the former could improve the contrast to noise ratio of a simulated perfusion defect by as much as 100% when compared to the latter.

  15. SPECT detectors: the Anger Camera and beyond

    NASA Astrophysics Data System (ADS)

    Peterson, Todd E.; Furenlid, Lars R.

    2011-09-01

    The development of radiation detectors capable of delivering spatial information about gamma-ray interactions was one of the key enabling technologies for nuclear medicine imaging and, eventually, single-photon emission computed tomography (SPECT). The continuous sodium iodide scintillator crystal coupled to an array of photomultiplier tubes, almost universally referred to as the Anger Camera after its inventor, has long been the dominant SPECT detector system. Nevertheless, many alternative materials and configurations have been investigated over the years. Technological advances as well as the emerging importance of specialized applications, such as cardiac and preclinical imaging, have spurred innovation such that alternatives to the Anger Camera are now part of commercial imaging systems. Increased computing power has made it practical to apply advanced signal processing and estimation schemes to make better use of the information contained in the detector signals. In this review we discuss the key performance properties of SPECT detectors and survey developments in both scintillator and semiconductor detectors and their readouts with an eye toward some of the practical issues at least in part responsible for the continuing prevalence of the Anger Camera in the clinic.

  16. SPECT detectors: the Anger Camera and beyond

    PubMed Central

    Peterson, Todd E.; Furenlid, Lars R.

    2011-01-01

    The development of radiation detectors capable of delivering spatial information about gamma-ray interactions was one of the key enabling technologies for nuclear medicine imaging and, eventually, single-photon emission computed tomography (SPECT). The continuous NaI(Tl) scintillator crystal coupled to an array of photomultiplier tubes, almost universally referred to as the Anger Camera after its inventor, has long been the dominant SPECT detector system. Nevertheless, many alternative materials and configurations have been investigated over the years. Technological advances as well as the emerging importance of specialized applications, such as cardiac and preclinical imaging, have spurred innovation such that alternatives to the Anger Camera are now part of commercial imaging systems. Increased computing power has made it practical to apply advanced signal processing and estimation schemes to make better use of the information contained in the detector signals. In this review we discuss the key performance properties of SPECT detectors and survey developments in both scintillator and semiconductor detectors and their readouts with an eye toward some of the practical issues at least in part responsible for the continuing prevalence of the Anger Camera in the clinic. PMID:21828904

  17. SPECT detectors: the Anger Camera and beyond.

    PubMed

    Peterson, Todd E; Furenlid, Lars R

    2011-09-01

    The development of radiation detectors capable of delivering spatial information about gamma-ray interactions was one of the key enabling technologies for nuclear medicine imaging and, eventually, single-photon emission computed tomography (SPECT). The continuous sodium iodide scintillator crystal coupled to an array of photomultiplier tubes, almost universally referred to as the Anger Camera after its inventor, has long been the dominant SPECT detector system. Nevertheless, many alternative materials and configurations have been investigated over the years. Technological advances as well as the emerging importance of specialized applications, such as cardiac and preclinical imaging, have spurred innovation such that alternatives to the Anger Camera are now part of commercial imaging systems. Increased computing power has made it practical to apply advanced signal processing and estimation schemes to make better use of the information contained in the detector signals. In this review we discuss the key performance properties of SPECT detectors and survey developments in both scintillator and semiconductor detectors and their readouts with an eye toward some of the practical issues at least in part responsible for the continuing prevalence of the Anger Camera in the clinic. PMID:21828904

  18. Development and optimization of SPECT gated blood pool cluster analysis for the prediction of CRT outcome

    SciTech Connect

    Lalonde, Michel Wassenaar, Richard; Wells, R. Glenn; Birnie, David; Ruddy, Terrence D.

    2014-07-15

    Purpose: Phase analysis of single photon emission computed tomography (SPECT) radionuclide angiography (RNA) has been investigated for its potential to predict the outcome of cardiac resynchronization therapy (CRT). However, phase analysis may be limited in its potential at predicting CRT outcome as valuable information may be lost by assuming that time-activity curves (TAC) follow a simple sinusoidal shape. A new method, cluster analysis, is proposed which directly evaluates the TACs and may lead to a better understanding of dyssynchrony patterns and CRT outcome. Cluster analysis algorithms were developed and optimized to maximize their ability to predict CRT response. Methods: About 49 patients (N = 27 ischemic etiology) received a SPECT RNA scan as well as positron emission tomography (PET) perfusion and viability scans prior to undergoing CRT. A semiautomated algorithm sampled the left ventricle wall to produce 568 TACs from SPECT RNA data. The TACs were then subjected to two different cluster analysis techniques, K-means, and normal average, where several input metrics were also varied to determine the optimal settings for the prediction of CRT outcome. Each TAC was assigned to a cluster group based on the comparison criteria and global and segmental cluster size and scores were used as measures of dyssynchrony and used to predict response to CRT. A repeated random twofold cross-validation technique was used to train and validate the cluster algorithm. Receiver operating characteristic (ROC) analysis was used to calculate the area under the curve (AUC) and compare results to those obtained for SPECT RNA phase analysis and PET scar size analysis methods. Results: Using the normal average cluster analysis approach, the septal wall produced statistically significant results for predicting CRT results in the ischemic population (ROC AUC = 0.73;p < 0.05 vs. equal chance ROC AUC = 0.50) with an optimal operating point of 71% sensitivity and 60% specificity. Cluster

  19. SPECT with (/sup 99m/Tc)-d,l-hexamethyl-propylene amine oxime (HM-PAO) compared with regional cerebral blood flow measured by PET: effects of linearization

    SciTech Connect

    Yonekura, Y.; Nishizawa, S.; Mukai, T.; Fujita, T.; Fukuyama, H.; Ishikawa, M.; Kikuchi, H.; Konishi, J.; Andersen, A.R.; Lassen, N.A.

    1988-12-01

    In order to validate the use of technetium-99m-d,l-hexamethylpropyleneamine oxime (HM-PAO) as a flow tracer, a total of 21 cases were studied with single photon emission computerized tomography (SPECT), and compared to regional cerebral blood flow (rCBF) measured by position emission tomography (PET) using the oxygen-15 CO2 inhalation technique. Although HM-PAO SPECT and rCBF PET images showed a similar distribution pattern the HM-PAO SPECT image showed less contrast between high and low activity flow regions than the rCBF image and a nonlinear relationship between HM-PAO activity and rCBF was shown. Based on the assumption of flow-dependent backdiffusion of HM-PAO from the brain, we applied a linearization algorithm to correct the HM-PAO SPECT images. The corrected HM-PAO SPECT images revealed a good linear correlation with rCBF (r = 0.901, p less than 0.001). The results indicated HM-PAO can be used as a flow tracer with SPECT after proper correction.

  20. Regional cerebral blood flow imaging: A quantitative comparison of technetium-99m-HMPAO SPECT with C15O2 PET

    SciTech Connect

    Gemmell, H.G.; Evans, N.T.; Besson, J.A.; Roeda, D.; Davidson, J.; Dodd, M.G.; Sharp, P.F.; Smith, F.W.; Crawford, J.R.; Newton, R.H. )

    1990-10-01

    The aim of this study was to compare technetium-99m-hexamethylpropyleneamineoxime ({sup 99m}Tc-HMPAO) single-photon emission computed tomography (SPECT) with regional cerebral blood flow (rCBF) imaging using positron emission tomography (PET). As investigation of dementia is likely to be one of the main uses of routine rCBF imaging, 18 demented patients were imaged with both techniques. The PET data were compared quantitatively with three versions of the SPECT data. These were, first, data normalized to the SPECT cerebellar uptake, second, data linearly corrected using the PET cerebellar value and, finally, data Lassen corrected for washout from the high flow areas. Both the linearly-corrected (r = 0.81) and the Lassen-corrected (r = 0.79) HMPAO SPECT data showed good correlation with the PET rCBF data. The relationship between the normalized HMPAO SPECT data and the PET data was nonlinear. It is not yet possible to obtain rCBF values in absolute units from HMPAO SPECT without knowledge of the true rCBF in one reference region for each patient.

  1. Design and assessment of cardiac SPECT systems

    NASA Astrophysics Data System (ADS)

    Lee, Chih-Jie

    Single-photon emission computed tomography (SPECT) is a modality widely used to detect myocardial ischemia and myocardial infarction. Objectively assessing and comparing different SPECT systems is important so that the best detectability of cardiac defects can be achieved. Whitaker, Clarkson, and Barrett's study on the scanning linear observer (SLO) shows that the SLO can be used to estimate the location and size of signals. One major advantage of the SLO is that it can be used with projection data rather than reconstruction data. Thus, this observer model assesses overall hardware performance independent by any reconstruction algorithm. In addition, we will show that the run time of image-quality studies is significantly reduced. Several systems derived from the GE CZT-based dedicated cardiac SPECT camera Discovery 530c design, which is officially named the Alcyone Technology: Discovery NM 530c, were assessed using the performance of the SLO for the task of detecting cardiac defects and estimating the properties of the defects. Clinically, hearts can be virtually segmented into three coronary artery territories: left anterior descending artery (LAD), left circumflex artery (LCX), and right coronary artery (RCA). One of the most important functions of a cardiac SPECT system is to produce images from which a radiologist can correctly predict in which territory the defect exists. A good estimation of the defect extent from the images is also very helpful for determining the seriousness of the myocardial ischemia. In this dissertation, both locations and extent of defects were estimated by the SLO, and system performance was assessed using localization receiver operating characteristic (LROC) / estimation receiver operating characteristic (EROC) curves. Area under LROC curve (AULC) / area under EROC curve (AUEC) and true positive fraction (TPF) at specific false positive fraction (FPF) can be treated as the gures of merit (FOMs). As the results will show, a

  2. Quantitative Monte Carlo-based holmium-166 SPECT reconstruction

    SciTech Connect

    Elschot, Mattijs; Smits, Maarten L. J.; Nijsen, Johannes F. W.; Lam, Marnix G. E. H.; Zonnenberg, Bernard A.; Bosch, Maurice A. A. J. van den; Jong, Hugo W. A. M. de; Viergever, Max A.

    2013-11-15

    Purpose: Quantitative imaging of the radionuclide distribution is of increasing interest for microsphere radioembolization (RE) of liver malignancies, to aid treatment planning and dosimetry. For this purpose, holmium-166 ({sup 166}Ho) microspheres have been developed, which can be visualized with a gamma camera. The objective of this work is to develop and evaluate a new reconstruction method for quantitative {sup 166}Ho SPECT, including Monte Carlo-based modeling of photon contributions from the full energy spectrum.Methods: A fast Monte Carlo (MC) simulator was developed for simulation of {sup 166}Ho projection images and incorporated in a statistical reconstruction algorithm (SPECT-fMC). Photon scatter and attenuation for all photons sampled from the full {sup 166}Ho energy spectrum were modeled during reconstruction by Monte Carlo simulations. The energy- and distance-dependent collimator-detector response was modeled using precalculated convolution kernels. Phantom experiments were performed to quantitatively evaluate image contrast, image noise, count errors, and activity recovery coefficients (ARCs) of SPECT-fMC in comparison with those of an energy window-based method for correction of down-scattered high-energy photons (SPECT-DSW) and a previously presented hybrid method that combines MC simulation of photopeak scatter with energy window-based estimation of down-scattered high-energy contributions (SPECT-ppMC+DSW). Additionally, the impact of SPECT-fMC on whole-body recovered activities (A{sup est}) and estimated radiation absorbed doses was evaluated using clinical SPECT data of six {sup 166}Ho RE patients.Results: At the same noise level, SPECT-fMC images showed substantially higher contrast than SPECT-DSW and SPECT-ppMC+DSW in spheres ≥17 mm in diameter. The count error was reduced from 29% (SPECT-DSW) and 25% (SPECT-ppMC+DSW) to 12% (SPECT-fMC). ARCs in five spherical volumes of 1.96–106.21 ml were improved from 32%–63% (SPECT-DSW) and 50%–80

  3. Uncertainty estimation for Bayesian reconstructions from low-count spect data

    SciTech Connect

    Cunningham, G.S.; Hanson, K.M.

    1996-12-31

    Bayesian analysis is especially useful to apply to low-count medical imaging data, such as gated cardiac SPECT, because it allows one to solve the nonlinear, ill-posed, inverse problems associated with such data. One advantage of the Bayesian approach is that it quantifies the uncertainty in estimated parameters through the posterior probability. We compare various approaches to exploring the uncertainty in Bayesian reconstructions from SPECT data including: the standard estimation of the covariance of an estimator using a frequentist approach; a new technique called the `hard truth` in which one applies `forces` to the parameters and observes their displacements; and Markov-chain Monte Carlo sampling of the posterior probability distribution, which in principle provides a complete uncertainty characterization.

  4. A single CT for attenuation correction of both rest and stress SPECT myocardial perfusion imaging: a retrospective feasibility study

    PubMed Central

    Ahlman, Mark A; Nietert, Paul J; Wahlquist, Amy E; Serguson, Jill M; Berry, Max W; Suranyi, Pal; Liu, Songtao; Spicer, Kenneth M

    2014-01-01

    Purpose: In the effort to reduce radiation exposure to patients undergoing myocardial perfusion imaging (MPI) with SPECT/CT, we evaluate the feasibility of a single CT for attenuation correction (AC) of single-day rest (R)/stress (S) perfusion. Methods: Processing of 20 single isotope and 20 dual isotope MPI with perfusion defects were retrospectively repeated in three steps: (1) the standard method using a concurrent R-CT for AC of R-SPECT and S-CT for S-SPECT; (2) the standard method repeated; and (3) with the R-CT used for AC of S-SPECT, and the S-CT used for AC of R-SPECT. Intra-Class Correlation Coefficients (ICC) and Choen’s kappa were used to measure intra-operator variability in sum scoring. Results: The highest level of intra-operator reliability was seen with the reproduction of the sum rest score (SRS) and sum stress score (SSS) (ICC > 95%). ICCs were > 85% for SRS and SSS when alternate CTs were used for AC, but when sum difference scores were calculated, ICC values were much lower (~22% to 27%), which may imply that neither CT substitution resulted in a reproducible difference score. Similar results were seen when evaluating dichotomous outcomes (sum scores difference of ≥ 4) when comparing different processing techniques (kappas ~0.32 to 0.43). Conclusions: When a single CT is used for AC of both rest and stress SPECT, there is disproportionately high variability in sum scoring that is independent of user error. This information can be used to direct further investigation in radiation reduction for common imaging exams in nuclear medicine. PMID:24482701

  5. Frequency-domain approaches to quantitative brain SPECT

    NASA Astrophysics Data System (ADS)

    Cheng, Jui-Hsi

    1997-12-01

    Quantitative SPECT (Single Photon Emission Computed Tomography) has been limited mainly by (1) inadequate numbers of detected photons which are contaminated by Poisson noise in projections, (2) photon attenuation in the body, (3) inclusion of scattered photons in the projections, and (4) depth-dependent blurring due to the finite size of collimator holes. Various methods to compensate for the above effects via either spatial- domain approaches or frequency-domain approaches have been proposed. However, most of the proposed methods focus only on individual effects. A reconstruction method which can compensate for all of the effects simultaneously is necessary. We have developed an algorithm to compensate for all of the effects simultaneously using frequency-domain approaches. For noise suppression, a method to convert the signal-dependent Poisson noise into signal- independent Gaussian white noise was first applied. Then the Wiener filter with a designed butterfly window was used. For scatter-photon removal, a subtraction technique based on multiple energy-window acquisitions was employed. For collimation deblurring, a direct inverse filter was designed via stationary phase condition (depth-frequency relationship). For attenuation compensation, an exact analytical solution was derived by Fourier analysis. Our algorithm was executed on a HP/730 workstation. An improvement was shown in computing time, noise suppression, recognition of phantom features, and quantification of concentrations of regions of interest (ROI). In addition to simulation, we performed a series of experiments to verify our models and test our algorithm. These include (1) investigation of the characteristics of Poisson noise of SPECT, (2) comparison of the performance of dual-energy window and triple-energy window methods for scatter correction, (3) measurement of a depth- dependent PSF, (4) reconstruction of the attenuation map using scatter-window data, and (5) implementation of a simultaneous

  6. Assessment of SPM in perfusion brain SPECT studies. A numerical simulation study using bootstrap resampling methods.

    PubMed

    Pareto, Deborah; Aguiar, Pablo; Pavía, Javier; Gispert, Juan Domingo; Cot, Albert; Falcón, Carles; Benabarre, Antoni; Lomeña, Francisco; Vieta, Eduard; Ros, Domènec

    2008-07-01

    Statistical parametric mapping (SPM) has become the technique of choice to statistically evaluate positron emission tomography (PET), functional magnetic resonance imaging (fMRI), and single photon emission computed tomography (SPECT) functional brain studies. Nevertheless, only a few methodological studies have been carried out to assess the performance of SPM in SPECT. The aim of this paper was to study the performance of SPM in detecting changes in regional cerebral blood flow (rCBF) in hypo- and hyperperfused areas in brain SPECT studies. The paper seeks to determine the relationship between the group size and the rCBF changes, and the influence of the correction for degradations. The assessment was carried out using simulated brain SPECT studies. Projections were obtained with Monte Carlo techniques, and a fan-beam collimator was considered in the simulation process. Reconstruction was performed by using the ordered subsets expectation maximization (OSEM) algorithm with and without compensation for attenuation, scattering, and spatial variant collimator response. Significance probability maps were obtained with SPM2 by using a one-tailed two-sample t-test. A bootstrap resampling approach was used to determine the sample size for SPM to detect the between-group differences. Our findings show that the correction for degradations results in a diminution of the sample size, which is more significant for small regions and low-activation factors. Differences in sample size were found between hypo- and hyperperfusion. These differences were larger for small regions and low-activation factors, and when no corrections were included in the reconstruction algorithm.

  7. Dual-energy micro-CT imaging of pulmonary airway obstruction: correlation with micro-SPECT

    NASA Astrophysics Data System (ADS)

    Badea, C. T.; Befera, N.; Clark, D.; Qi, Y.; Johnson, G. A.

    2014-03-01

    To match recent clinical dual energy (DE) CT studies focusing on the lung, similar developments for DE micro-CT of the rodent lung are required. Our group has been actively engaged in designing pulmonary gating techniques for micro- CT, and has also introduced the first DE micro-CT imaging method of the rodent lung. The aim of this study was to assess the feasibility of DE micro-CT imaging for the evaluation of airway obstruction in mice, and to compare the method with micro single photon emission computed tomography (micro-SPECT) using technetium-99m labeled macroaggregated albumin (99mTc-MAA). The results suggest that the induced pulmonary airway obstruction causes either atelectasis, or air-trapping similar to asthma or chronic bronchitis. Atelectasis could only be detected at early time points in DE micro-CT images, and is associated with a large increase in blood fraction and decrease in air fraction. Air trapping had an opposite effect with larger air fraction and decreased blood fraction shown by DE micro-CT. The decrease in perfusion to the hypoventilated lung (hypoxic vasoconstriction) is also seen in micro-SPECT. The proposed DE micro-CT technique for imaging localized airway obstruction performed well in our evaluation, and provides a higher resolution compared to micro-SPECT. Both DE micro-CT and micro-SPECT provide critical, quantitative lung biomarkers for image-based anatomical and functional information in the small animal. The methods are readily linked to clinical methods allowing direct comparison of preclinical and clinical results.

  8. Brain perfusion SPECT in the mouse: normal pattern according to gender and age.

    PubMed

    Apostolova, Ivayla; Wunder, Andreas; Dirnagl, Ulrich; Michel, Roger; Stemmer, Nina; Lukas, Mathias; Derlin, Thorsten; Gregor-Mamoudou, Betina; Goldschmidt, Jürgen; Brenner, Winfried; Buchert, Ralph

    2012-12-01

    .7%, p=0.000) and at young adult age (AI=2.4 ± 1.7%, p=0.000). Gender had no effect on asymmetry. Voxel-wise testing confirmed the ROI-based findings. In conclusion, high-resolution HMPAO SPECT is a promising technique for measuring rCBF in preclinical research. It indicates lateral asymmetry of rCBF in the mouse brain as well as age-related changes during late maturation. ECD is not suitable as tracer for brain SPECT in the mouse because of its fast clearance from tissue indicating an interspecies difference in esterase activity between mice and humans.

  9. Bayesian learning for cardiac SPECT image interpretation.

    PubMed

    Sacha, Jarosław P; Goodenday, Lucy S; Cios, Krzysztof J

    2002-01-01

    In this paper, we describe a system for automating the diagnosis of myocardial perfusion from single-photon emission computerized tomography (SPECT) images of male and female hearts. Initially we had several thousand of SPECT images, other clinical data and physician-interpreter's descriptions of the images. The images were divided into segments based on the Yale system. Each segment was described by the physician as showing one of the following conditions: normal perfusion, reversible perfusion defect, partially reversible perfusion defect, fixed perfusion defect, defect showing reverse redistribution, equivocal defect or artifact. The physician's diagnosis of overall left ventricular (LV) perfusion, based on the above descriptions, categorizes a study as showing one or more of eight possible conditions: normal, ischemia, infarct and ischemia, infarct, reverse redistribution, equivocal, artifact or LV dysfunction. Because of the complexity of the task, we decided to use the knowledge discovery approach, consisting of these steps: problem understanding, data understanding, data preparation, data mining, evaluating the discovered knowledge and its implementation. After going through the data preparation step, in which we constructed normal gender-specific models of the LV and image registration, we ended up with 728 patients for whom we had both SPECT images and corresponding diagnoses. Another major contribution of the paper is the data mining step, in which we used several new Bayesian learning classification methods. The approach we have taken, namely the six-step knowledge discovery process has proven to be very successful in this complex data mining task and as such the process can be extended to other medical data mining projects.

  10. Bone SPECT/CT in skeletal trauma.

    PubMed

    Scharf, Stephen C

    2015-01-01

    The utility of radionuclide bone scanning in skeletal trauma has been greatly enhanced over the last decade by hybrid technology merging multislice CT with SPECT that can take advantage of CT-based correction of attenuation and scatter. The resulting images have been particularly helpful in giving us new insights into the evaluation of foot and ankle injuries and vertebral pathology both before and after surgery. The physiological information and anatomical detail allow a better understanding of the causes of patients' pain and have proven to be particularly useful in planning surgical intervention.

  11. Functional brain abnormalities localized in 55 chronic tinnitus patients: fusion of SPECT coincidence imaging and MRI

    PubMed Central

    Farhadi, Mohammad; Mahmoudian, Saeid; Saddadi, Fariba; Karimian, Ali Reza; Mirzaee, Mohammad; Ahmadizadeh, Majid; Ghasemikian, Khosro; Gholami, Saeid; Ghoreyshi, Esmaeel; Beyty, Saeid; Shamshiri, Ahmadreza; Madani, Sedighe; Bakaev, Valery; Moradkhani, Seddighe; Raeisali, Gholamreza

    2010-01-01

    Tinnitus is often defined as the perception of sounds or noise in the absence of any external auditory stimuli. The pathophysiology of subjective idiopathic tinnitus remains unclear. The aim of this study was to investigate the functional brain activities and possible involved cerebral areas in subjective idiopathic tinnitus patients by means of single photon emission computerized tomography (SPECT) coincidence imaging, which was fused with magnetic resonance imaging (MRI). In this cross-sectional study, 56 patients (1 subject excluded) with subjective tinnitus and 8 healthy controls were enrolled. After intravenous injection of 5 mCi F18-FDG (fluorodeoxyglucose), all subjects underwent a brain SPECT coincidence scan, which was then superimposed on their MRIs. In the eight regions of interest (middle temporal, inferotemporal, medial temporal, lateral temporal, temporoparietal, frontal, frontoparietal, and parietal areas), the more pronounced values were represented in medial temporal, inferotemporal, and temporoparietal areas, which showed more important proportion of associative auditory cortices in functional attributions of tinnitus than primary auditory cortex. Brain coincidence SPECT scan, when fused on MRI is a valuable technique in the assessment of patients with tinnitus and could show the significant role of different regions of central nervous system in functional attributions of tinnitus. PMID:20068582

  12. Functional brain abnormalities localized in 55 chronic tinnitus patients: fusion of SPECT coincidence imaging and MRI.

    PubMed

    Farhadi, Mohammad; Mahmoudian, Saeid; Saddadi, Fariba; Karimian, Ali Reza; Mirzaee, Mohammad; Ahmadizadeh, Majid; Ghasemikian, Khosro; Gholami, Saeid; Ghoreyshi, Esmaeel; Beyty, Saeid; Shamshiri, Ahmadreza; Madani, Sedighe; Bakaev, Valery; Moradkhani, Seddighe; Raeisali, Gholamreza

    2010-04-01

    Tinnitus is often defined as the perception of sounds or noise in the absence of any external auditory stimuli. The pathophysiology of subjective idiopathic tinnitus remains unclear. The aim of this study was to investigate the functional brain activities and possible involved cerebral areas in subjective idiopathic tinnitus patients by means of single photon emission computerized tomography (SPECT) coincidence imaging, which was fused with magnetic resonance imaging (MRI). In this cross-sectional study, 56 patients (1 subject excluded) with subjective tinnitus and 8 healthy controls were enrolled. After intravenous injection of 5 mCi F18-FDG (fluorodeoxyglucose), all subjects underwent a brain SPECT coincidence scan, which was then superimposed on their MRIs. In the eight regions of interest (middle temporal, inferotemporal, medial temporal, lateral temporal, temporoparietal, frontal, frontoparietal, and parietal areas), the more pronounced values were represented in medial temporal, inferotemporal, and temporoparietal areas, which showed more important proportion of associative auditory cortices in functional attributions of tinnitus than primary auditory cortex. Brain coincidence SPECT scan, when fused on MRI is a valuable technique in the assessment of patients with tinnitus and could show the significant role of different regions of central nervous system in functional attributions of tinnitus.

  13. Is Brown Adipose Tissue Visualization Reliable on 99mTc-Methoxyisobutylisonitrile Diagnostic SPECT Scintigraphy?

    PubMed Central

    Haghighatafshar, Mahdi; Farhoudi, Farinaz

    2016-01-01

    Abstract The 99mTc-MIBI has been used with great value as a diagnostic technique in patients with primary hyperparathyroidism. False-positive scans may occur due to misinterpretation of the physiologic distribution of the 99mTc-MIBI. Reviewing consecutive SPECT scans, we evaluated this possibility and assessed how frequently brown adipose tissue (BAT) is seen on 99mTc-MIBI scintigraphy. Here, we retrospectively reviewed scans of consecutive patients who were evaluated for parathyroid adenomas from March 2015 to June 2015, using dual-phase (early and delayed) planar imaging and SPECT. We identified 60 patients (48 female and 12 male; mean age, 52.25 ± 15.20 years; range, 22–86 years). We detected the presence of 99mTc-MIBI uptake in BAT in 20 of 60 patients (33.33%) in the neck. Although the patients with 99mTc-MIBI uptake in BAT were younger (mean age, 48.85 ± 15.27 years, range, 26–73 years) than the patients with no 99mTc-MIBI uptake (mean age, 53.95 ± 15.07 years, range, 22–86 years), this difference was not statistically significant (P = 0.224). The percentage of female patients with BAT detection was higher (17/48 patients; 37.5%) than that of the male population (3/12 patients; 25%), this difference was not also statistically significant (P = 0.85). In patient population referred to 99mTc MIBI scintigraphy of the parathyroid glands, uptake of 99mTc-MIBI in BAT should not be misinterpreted with 99mTc-MIBI-avid-tumors. Fused SPECT/CT images (not SPECT-only) are necessary to distinguish BAT from bone, muscle, thyroid, myocardium, parathyroids, and other structures in the neck and chest. PMID:26765463

  14. Performance evaluation of a pinhole SPECT system for myocardial perfusion imaging of mice.

    PubMed

    Wu, Max C; Hasegawa, Bruce H; Dae, Michael W

    2002-12-01

    The increasing use of transgenic mice as models of human physiology and disease has motivated the development of dedicated in vivo imaging systems for anatomic and functional characterization of mice as an adjunct to or a replacement for established ex vivo techniques. We have developed a pinhole single photon emission computed tomography (SPECT) system for high resolution imaging of mice with cardiovascular imaging as the primary application. In this work, we characterize the system performance through phantom studies. The spatial resolution and sensitivity were measured from images of a line source and point source, respectively, and were reported for a range of object-to-pinhole distances and pinhole diameters. Tomographic images of a uniform cylindrical phantom, Defrise phantom, and grid phantom were used to characterize the image uniformity and spatial linearity. The uniform phantom image did not contain any ring or reconstruction artifacts, but blurring in the axial direction was evident in the Defrise phantom images. The grid phantom images demonstrated excellent spatial linearity. A novel phantom modeling perfusion of the left ventricle of a mouse was designed and built with perfusion defects of varying sizes to evaluate the system performance for myocardial perfusion imaging of mice. The defect volumes were measured from the pinhole SPECT images and correlated to the actual defect volumes calculated according to geometric formulas. Linear regression analysis produced a correlation coefficient of r = 0.995 (p < 0.001), demonstrating the feasibility for measurement of perfusion defect size in mice using pinhole SPECT. We have performed phantom studies to characterize the spatial resolution, sensitivity, image uniformity, and spatial linearity of the pinhole SPECT system. Measurement of the perfusion defect size is a valuable phenotypic assessment and will be useful for hypothesis testing in murine models of cardiovascular disease.

  15. Multi-resolution multi-sensitivity design for parallel-hole SPECT collimators.

    PubMed

    Li, Yanzhao; Xiao, Peng; Zhu, Xiaohua; Xie, Qingguo

    2016-07-21

    Multi-resolution multi-sensitivity (MRMS) collimator offering adjustable trade-off between resolution and sensitivity, can make a SPECT system adaptive. We propose in this paper a new idea for MRMS design based on, for the first time, parallel-hole collimators for clinical SPECT. Multiple collimation states with varied resolution/sensitivity trade-offs can be formed by slightly changing the collimator's inner structure. To validate the idea, the GE LEHR collimator is selected as the design prototype and is modeled using a ray-tracing technique. Point images are generated for several states of the design. Results show that the collimation states of the design can obtain similar point response characteristics to parallel-hole collimators, and can be used just like parallel-hole collimators in clinical SPECT imaging. Ray-tracing modeling also shows that the proposed design can offer varied resolution/sensitivity trade-offs: at 100 mm before the collimator, the highest resolution state provides 6.9 mm full width at a half maximum (FWHM) with a nearly minimum sensitivity of about 96.2 cps MBq(-1), while the lowest resolution state obtains 10.6 mm FWHM with the highest sensitivity of about 167.6 cps MBq(-1). Further comparisons of the states on image qualities are conducted through Monte Carlo simulation of a hot-spot phantom which contains five hot spots with varied sizes. Contrast-to-noise ratios (CNR) of the spots are calculated and compared, showing that different spots can prefer different collimation states: the larger spots obtain better CNRs by using the larger sensitivity states, and the smaller spots prefer the higher resolution states. In conclusion, the proposed idea can be an effective approach for MRMS design for parallel-hole SPECT collimators. PMID:27359049

  16. Multi-resolution multi-sensitivity design for parallel-hole SPECT collimators

    NASA Astrophysics Data System (ADS)

    Li, Yanzhao; Xiao, Peng; Zhu, Xiaohua; Xie, Qingguo

    2016-07-01

    Multi-resolution multi-sensitivity (MRMS) collimator offering adjustable trade-off between resolution and sensitivity, can make a SPECT system adaptive. We propose in this paper a new idea for MRMS design based on, for the first time, parallel-hole collimators for clinical SPECT. Multiple collimation states with varied resolution/sensitivity trade-offs can be formed by slightly changing the collimator’s inner structure. To validate the idea, the GE LEHR collimator is selected as the design prototype and is modeled using a ray-tracing technique. Point images are generated for several states of the design. Results show that the collimation states of the design can obtain similar point response characteristics to parallel-hole collimators, and can be used just like parallel-hole collimators in clinical SPECT imaging. Ray-tracing modeling also shows that the proposed design can offer varied resolution/sensitivity trade-offs: at 100 mm before the collimator, the highest resolution state provides 6.9 mm full width at a half maximum (FWHM) with a nearly minimum sensitivity of about 96.2 cps MBq‑1, while the lowest resolution state obtains 10.6 mm FWHM with the highest sensitivity of about 167.6 cps MBq‑1. Further comparisons of the states on image qualities are conducted through Monte Carlo simulation of a hot-spot phantom which contains five hot spots with varied sizes. Contrast-to-noise ratios (CNR) of the spots are calculated and compared, showing that different spots can prefer different collimation states: the larger spots obtain better CNRs by using the larger sensitivity states, and the smaller spots prefer the higher resolution states. In conclusion, the proposed idea can be an effective approach for MRMS design for parallel-hole SPECT collimators.

  17. Myocardial Infarction Area Quantification using High-Resolution SPECT Images in Rats

    PubMed Central

    de Oliveira, Luciano Fonseca Lemos; Mejia, Jorge; de Carvalho, Eduardo Elias Vieira; Lataro, Renata Maria; Frassetto, Sarita Nasbine; Fazan, Rubens; Salgado, Hélio Cesar; Galvis-Alonso, Orfa Yineth; Simões, Marcus Vinícius

    2013-01-01

    Background Imaging techniques enable in vivo sequential assessment of the morphology and function of animal organs in experimental models. We developed a device for high-resolution single photon emission computed tomography (SPECT) imaging based on an adapted pinhole collimator. Objective To determine the accuracy of this system for quantification of myocardial infarct area in rats. Methods Thirteen male Wistar rats (250 g) underwent experimental myocardial infarction by occlusion of the left coronary artery. After 4 weeks, SPECT images were acquired 1.5 hours after intravenous injection of 555 MBq of 99mTc-Sestamibi. The tomographic reconstruction was performed by using specially developed software based on the Maximum Likelihood algorithm. The analysis of the data included the correlation between the area of perfusion defects detected by scintigraphy and extent of myocardial fibrosis assessed by histology. Results The images showed a high target organ/background ratio with adequate visualization of the left ventricular walls and cavity. All animals presenting infarction areas were correctly identified by the perfusion images. There was no difference of the infarct area as measured by SPECT (21.1 ± 21.2%) and by histology (21.7 ± 22.0%; p=0.45). There was a strong correlation between individual values of the area of infarction measured by these two methods. Conclusion The developed system presented adequate spatial resolution and high accuracy for the detection and quantification of myocardial infarction areas, consisting in a low cost and versatile option for high-resolution SPECT imaging of small rodents. PMID:23917507

  18. Multi-resolution multi-sensitivity design for parallel-hole SPECT collimators.

    PubMed

    Li, Yanzhao; Xiao, Peng; Zhu, Xiaohua; Xie, Qingguo

    2016-07-21

    Multi-resolution multi-sensitivity (MRMS) collimator offering adjustable trade-off between resolution and sensitivity, can make a SPECT system adaptive. We propose in this paper a new idea for MRMS design based on, for the first time, parallel-hole collimators for clinical SPECT. Multiple collimation states with varied resolution/sensitivity trade-offs can be formed by slightly changing the collimator's inner structure. To validate the idea, the GE LEHR collimator is selected as the design prototype and is modeled using a ray-tracing technique. Point images are generated for several states of the design. Results show that the collimation states of the design can obtain similar point response characteristics to parallel-hole collimators, and can be used just like parallel-hole collimators in clinical SPECT imaging. Ray-tracing modeling also shows that the proposed design can offer varied resolution/sensitivity trade-offs: at 100 mm before the collimator, the highest resolution state provides 6.9 mm full width at a half maximum (FWHM) with a nearly minimum sensitivity of about 96.2 cps MBq(-1), while the lowest resolution state obtains 10.6 mm FWHM with the highest sensitivity of about 167.6 cps MBq(-1). Further comparisons of the states on image qualities are conducted through Monte Carlo simulation of a hot-spot phantom which contains five hot spots with varied sizes. Contrast-to-noise ratios (CNR) of the spots are calculated and compared, showing that different spots can prefer different collimation states: the larger spots obtain better CNRs by using the larger sensitivity states, and the smaller spots prefer the higher resolution states. In conclusion, the proposed idea can be an effective approach for MRMS design for parallel-hole SPECT collimators.

  19. Is Brown Adipose Tissue Visualization Reliable on 99mTc-Methoxyisobutylisonitrile Diagnostic SPECT Scintigraphy?

    PubMed

    Haghighatafshar, Mahdi; Farhoudi, Farinaz

    2016-01-01

    The 99mTc-MIBI has been used with great value as a diagnostic technique in patients with primary hyperparathyroidism. False-positive scans may occur due to misinterpretation of the physiologic distribution of the 99mTc-MIBI. Reviewing consecutive SPECT scans, we evaluated this possibility and assessed how frequently brown adipose tissue (BAT) is seen on 99mTc-MIBI scintigraphy. Here, we retrospectively reviewed scans of consecutive patients who were evaluated for parathyroid adenomas from March 2015 to June 2015, using dual-phase (early and delayed) planar imaging and SPECT. We identified 60 patients (48 female and 12 male; mean age, 52.25 ± 15.20 years; range, 22-86 years).We detected the presence of 99mTc-MIBI uptake in BAT in 20 of 60 patients (33.33%) in the neck. Although the patients with T99mc-MIBI uptake in BAT were younger (mean age, 48.85 ± 15.27 years, range, 26-73 years) than the patients with no 99mTc-MIBI uptake (mean age, 53.95 ± 15.07 years, range, 22-86 years), this difference was not statistically significant (P = 0.224). The percentage of female patients with BAT detection was higher (17/48 patients; 37.5%) than that of the male population (3/12 patients; 25%), this difference was not also statistically significant (P = 0.85).In patient population referred to 99mTc MIBI scintigraphy of the parathyroid glands, uptake of 99mTc-MIBI in BAT should not be misinterpreted with 99mTc-MIBI-avid-tumors. Fused SPECT/CT images (not SPECT-only) are necessary to distinguish BAT from bone, muscle, thyroid, myocardium, parathyroids, and other structures in the neck and chest. PMID:26765463

  20. SPECT/CT Fusion in the Diagnosis of Hyperparathyroidism

    PubMed Central

    Monzen, Yoshio; Tamura, Akihisa; Okazaki, Hajime; Kurose, Taichi; Kobayashi, Masayuki; Kuraoka, Masatsugu

    2015-01-01

    Objective(s): In this study, we aimed to analyze the relationship between the diagnostic ability of fused single photon emission computed tomography/ computed tomography (SPECT/CT) images in localization of parathyroid lesions and the size of adenomas or hyperplastic glands. Methods: Five patients with primary hyperparathyroidism (PHPT) and 4 patients with secondary hyperparathyroidism (SHPT) were imaged 15 and 120 minutes after the intravenous injection of technetium99m-methoxyisobutylisonitrile (99mTc-MIBI). All patients underwent surgery and 5 parathyroid adenomas and 10 hyperplastic glands were detected. Pathologic findings were correlated with imaging results. Results: The SPECT/CT fusion images were able to detect all parathyroid adenomas even with the greatest axial diameter of 0.6 cm. Planar scintigraphy and SPECT imaging could not detect parathyroid adenomas with an axial diameter of 1.0 to 1.2 cm. Four out of 10 (40%) hyperplastic parathyroid glands were diagnosed, using planar and SPECT imaging and 5 out of 10 (50%) hyperplastic parathyroid glands were localized, using SPECT/CT fusion images. Conclusion: SPECT/CT fusion imaging is a more useful tool for localization of parathyroid lesions, particularly parathyroid adenomas, in comparison with planar and or SPECT imaging. PMID:27408883

  1. SPECT-US image fusion and clinical applications

    NASA Astrophysics Data System (ADS)

    Hummel, Johann; Kaar, Marcus; Hoffmann, Rainer; Birkfellner, Wolfgang; Beyer, Thomas; Staudenherz, Anton; Figl, Michael

    2014-03-01

    Because scintigraphic images lack anatomical information, single photon emission tomography (SPECT) and positron emission tomography systems (PET) are combined physically with CTs to compensate for this drawback. In our work, we present a method where the CT is replaced by a 3D ultrasound device. Because in this case a mechanical linkage is not possible, we use an additional optical tracking system (OTS) for spatial correlation of the SPECT or PET information and the US. To enable image fusion between the functional SPECT and the anatomical US we first calibrate the SPECT by means of the optical tracking system. This is done by imaging a phantom with SPECT and scanning the surface of the phantom using a calibrated stylus of the OTS. Applying an iterative closest point (ICP) algorithm results in the transformation between the optical coordinate system and the SPECT coordinate system. When a patient undergoes a SPECT scan, a 3D US image is taken immediately after the scan. Since the scan head of the US is also tracked by the OTS, the transformation between OTS and SPECT can be calculated straight forward. For clinical intervention, the patient is again imaged with the US and a 3D/3D registration between the two US volumes allows to transform the functional information of the SPECT to the current US image in real time. We found a mean distance between the point cloud of the optical stylus and the segmented surface of the phantom of 2.3 mm while the maximum distance was found to be 6.9 mm. The 3D3D registration between the two US images was accomplished with an error of 2.1 mm.

  2. MLEM algorithm adaptation for improved SPECT scintimammography

    NASA Astrophysics Data System (ADS)

    Krol, Andrzej; Feiglin, David H.; Lee, Wei; Kunniyur, Vikram R.; Gangal, Kedar R.; Coman, Ioana L.; Lipson, Edward D.; Karczewski, Deborah A.; Thomas, F. Deaver

    2005-04-01

    Standard MLEM and OSEM algorithms used in SPECT Tc-99m sestamibi scintimammography produce hot-spot artifacts (HSA) at the image support peripheries. We investigated a suitable adaptation of MLEM and OSEM algorithms needed to reduce HSA. Patients with suspicious breast lesions were administered 10 mCi of Tc-99m sestamibi and SPECT scans were acquired for patients in prone position with uncompressed breasts. In addition, to simulate breast lesions, some patients were imaged with a number of breast skin markers each containing 1 mCi of Tc-99m. In order to reduce HSA in reconstruction, we removed from the backprojection step the rays that traverse the periphery of the support region on the way to a detector bin, when their path length through this region was shorter than some critical length. Such very short paths result in a very low projection counts contributed to the detector bin, and consequently to overestimation of the activity in the peripheral voxels in the backprojection step-thus creating HSA. We analyzed the breast-lesion contrast and suppression of HSA in the images reconstructed using standard and modified MLEM and OSEM algorithms vs. critical path length (CPL). For CPL >= 0.01 pixel size, we observed improved breast-lesion contrast and lower noise in the reconstructed images, and a very significant reduction of HSA in the maximum intensity projection (MIP) images.

  3. Detection models for freehand SPECT reconstruction

    NASA Astrophysics Data System (ADS)

    Hartl, Alexander; Shakir, Dzhoshkun I.; Lasser, Tobias; Ziegler, Sibylle I.; Navab, Nassir

    2015-02-01

    Nuclear imaging modalities are commonly used tools in today’s diagnostics and therapy planning. However for interventional use they suffer from drawbacks which limit their application. Freehand SPECT was developed to provide 3D functional imaging during interventions. It combines a nuclear detector with an optical tracking system to obtain its position and orientation in space and synchronizes this with the detector readings. This information can be used to compute a 3D tomographic reconstruction of an activity distribution of a nuclear tracer. As there is no fixed geometry, the system matrix has to be computed on the fly. This is done with models of the detection process for completely arbitrary freehand acquisitions. The accuracy of the reconstructions is highly dependent on the used models of the detection process. Different models of the detection process were developed and evaluated in this work, in particular two analytical models as well as lookup tables generated from either real measurements or Monte Carlo simulations. We showed that it is possible to perform acceptable reconstructions with a simple but efficient analytical model. The use of lookup tables to generate the system matrix in Freehand SPECT is a fast solution with good accuracy.

  4. Freehand SPECT reconstructions using look up tables

    NASA Astrophysics Data System (ADS)

    Hartl, Alexander; Shakir, Dzhoshkun I.; Kojchev, Risto; Navab, Nassir; Ziegler, Sibylle I.; Lasser, Tobias

    2012-02-01

    Nuclear imaging is a commonly used tool in today's diagnostics and therapy planning. For interventional use however it suffers from drawbacks which limit its application. Freehand SPECT was developed to overcome these limitations and to provide 3D functional imaging during an intervention. It combines a nuclear probe with an optical tracking system to obtain its position and orientation in space synchronized with its reading. This information can be used to compute a 3D tomographic reconstruction of an activity distribution. However, as there is no fixed geometry the system matrix has to be computed on-the-fly, using ad-hoc models of the detection process. One solution for such a model is a reference look up table of previously acquired measurements of a single source at different angles and distances. In this work two look up tables with a one and four millimeter step size between the entries were acquired. Twelve datasets of a phantom with two hollow spheres filled with a solution of Tc99wm were acquired with the Freehand SPECT system. Reconstructions with the look up tables and two analytical models currently in use were performed with these datasets and compared with each other. The finely sampled look up table achieved the qualitatively best reconstructions, while one of the analytical models showed the best positional accuracy.

  5. Clinical validation of SPECT and CT/MRI image registration in radiolabeled monoclonal antibody studies of colorectal carcinoma

    SciTech Connect

    Scott, A.M.; Macapinlac, H.A.; Divgi, C.R.

    1994-12-01

    Registration methods combine the anatomic localizing ability of CT or MRI with SPECT images of radiolabeled monocional antibodies (Mabs), allowing the accurate staging of patients prior to surgery or following treatment. Twenty-four patients (15 males and 9 females, mean age 55 yr, range 29-70 yr) were studied with this technique. Ten patients had suspected colorectal cancer recurrence and were infused with 10 mCi of {sup 131}I-CC49 prior to staging laparotomy. Fourteen patients treated in a Phase 1 radioimmunotherapy study with {sup 131}I-CC49 were also studied. All patients underwent SPECT imaging of the abdomen and pelvis 5-7 days following infusion of Mab. Phantom studies demonstrated a 3.6-mm surface fitting mean accurracy of datasets for the liver and 1.8 mm for an intrahepatic tumor. In the presurgical group, SPECT and CT/MRI registration allowed more accurate identification of uptake abnormal sites. Areas of metastatic disease > 1 cm confirmed at surgery were found in six of nine patients with liver lesions and in two patients with extrahepatic (including one patient with pelvic) disease. In patients imaged following radioimmunotherapy, all lesions > 1.5 cm seen on CT/MRI were identified, and activity distribution in tumor and normal tissue could be more accurately assessed. Routine registration of SPECT and CT/MRI images is feasible and allows more accurate anatomic assessment of sites of abnormal uptake in radiolabeled Mab studies. 41 refs., 5 figs., 2 tabs.

  6. Image reconstruction of single photon emission computed tomography (SPECT) on a pebble bed reactor (PBR) using expectation maximization and exact inversion algorithms: Comparison study by means of numerical phantom

    NASA Astrophysics Data System (ADS)

    Razali, Azhani Mohd; Abdullah, Jaafar

    2015-04-01

    Single Photon Emission Computed Tomography (SPECT) is a well-known imaging technique used in medical application, and it is part of medical imaging modalities that made the diagnosis and treatment of disease possible. However, SPECT technique is not only limited to the medical sector. Many works are carried out to adapt the same concept by using high-energy photon emission to diagnose process malfunctions in critical industrial systems such as in chemical reaction engineering research laboratories, as well as in oil and gas, petrochemical and petrochemical refining industries. Motivated by vast applications of SPECT technique, this work attempts to study the application of SPECT on a Pebble Bed Reactor (PBR) using numerical phantom of pebbles inside the PBR core. From the cross-sectional images obtained from SPECT, the behavior of pebbles inside the core can be analyzed for further improvement of the PBR design. As the quality of the reconstructed image is largely dependent on the algorithm used, this work aims to compare two image reconstruction algorithms for SPECT, namely the Expectation Maximization Algorithm and the Exact Inversion Formula. The results obtained from the Exact Inversion Formula showed better image contrast and sharpness, and shorter computational time compared to the Expectation Maximization Algorithm.

  7. Image reconstruction of single photon emission computed tomography (SPECT) on a pebble bed reactor (PBR) using expectation maximization and exact inversion algorithms: Comparison study by means of numerical phantom

    SciTech Connect

    Razali, Azhani Mohd Abdullah, Jaafar

    2015-04-29

    Single Photon Emission Computed Tomography (SPECT) is a well-known imaging technique used in medical application, and it is part of medical imaging modalities that made the diagnosis and treatment of disease possible. However, SPECT technique is not only limited to the medical sector. Many works are carried out to adapt the same concept by using high-energy photon emission to diagnose process malfunctions in critical industrial systems such as in chemical reaction engineering research laboratories, as well as in oil and gas, petrochemical and petrochemical refining industries. Motivated by vast applications of SPECT technique, this work attempts to study the application of SPECT on a Pebble Bed Reactor (PBR) using numerical phantom of pebbles inside the PBR core. From the cross-sectional images obtained from SPECT, the behavior of pebbles inside the core can be analyzed for further improvement of the PBR design. As the quality of the reconstructed image is largely dependent on the algorithm used, this work aims to compare two image reconstruction algorithms for SPECT, namely the Expectation Maximization Algorithm and the Exact Inversion Formula. The results obtained from the Exact Inversion Formula showed better image contrast and sharpness, and shorter computational time compared to the Expectation Maximization Algorithm.

  8. Fabrication of the pinhole aperture for AdaptiSPECT

    PubMed Central

    Kovalsky, Stephen; Kupinski, Matthew A.; Barrett, Harrison H.; Furenlid, Lars R.

    2015-01-01

    AdaptiSPECT is a pre-clinical pinhole SPECT imaging system under final construction at the Center for Gamma-Ray Imaging. The system is designed to be able to autonomously change its imaging configuration. The system comprises 16 detectors mounted on translational stages to move radially away and towards the center of the field-of-view. The system also possesses an adaptive pinhole aperture with multiple collimator diameters and pinhole sizes, as well as the possibility to switch between multiplexed and non-multiplexed imaging configurations. In this paper, we describe the fabrication of the AdaptiSPECT pinhole aperture and its controllers. PMID:26146443

  9. A line-source method for aligning on-board and other pinhole SPECT systems

    PubMed Central

    Yan, Susu; Bowsher, James; Yin, Fang-Fang

    2013-01-01

    the Radon transform, estimation accuracy was reduced. The estimation error was associated with rounding errors of Radon transform, finite line-source width, Poisson noise, number of line sources, intrinsic camera resolution, and detector acquisition geometry. Statistically, the estimation accuracy was significantly improved by using four line sources rather than three and by thinner line-source projections (obtained by better intrinsic detector resolution). With five line sources, median errors were 0.2 mm for the detector translations, 0.7 mm for the detector radius of rotation, and less than 0.5° for detector rotation, tilt, and twist. In experimental evaluations, average errors relative to a different, independent registration technique were about 1.8 mm for detector translations, 1.1 mm for the detector radius of rotation (ROR), 0.5° and 0.4° for detector rotation and tilt, respectively, and 1.2° for detector twist. Conclusions: Alignment parameters can be estimated using one pinhole projection of line sources. Alignment errors are largely associated with limited accuracy of the Radon transform in determining angles (α) and offsets (ρ) of the line-source projections. This alignment method may be important for multipinhole SPECT, where relative pinhole alignment may vary during rotation. For pinhole and multipinhole SPECT imaging on-board radiation therapy machines, the method could provide alignment of SPECT coordinates with those of CBCT and the LINAC. PMID:24320537

  10. A line-source method for aligning on-board and other pinhole SPECT systems

    SciTech Connect

    Yan, Susu; Bowsher, James; Yin, Fang-Fang

    2013-12-15

    the Radon transform, estimation accuracy was reduced. The estimation error was associated with rounding errors of Radon transform, finite line-source width, Poisson noise, number of line sources, intrinsic camera resolution, and detector acquisition geometry. Statistically, the estimation accuracy was significantly improved by using four line sources rather than three and by thinner line-source projections (obtained by better intrinsic detector resolution). With five line sources, median errors were 0.2 mm for the detector translations, 0.7 mm for the detector radius of rotation, and less than 0.5° for detector rotation, tilt, and twist. In experimental evaluations, average errors relative to a different, independent registration technique were about 1.8 mm for detector translations, 1.1 mm for the detector radius of rotation (ROR), 0.5° and 0.4° for detector rotation and tilt, respectively, and 1.2° for detector twist.Conclusions: Alignment parameters can be estimated using one pinhole projection of line sources. Alignment errors are largely associated with limited accuracy of the Radon transform in determining angles (α) and offsets (ρ) of the line-source projections. This alignment method may be important for multipinhole SPECT, where relative pinhole alignment may vary during rotation. For pinhole and multipinhole SPECT imaging on-board radiation therapy machines, the method could provide alignment of SPECT coordinates with those of CBCT and the LINAC.

  11. Simultaneous Tc-99m/I-123 dual-radionuclide myocardial perfusion/innervation imaging using Siemens IQ-SPECT with SMARTZOOM collimator

    NASA Astrophysics Data System (ADS)

    Du, Yong; Bhattacharya, Manojeet; Frey, Eric C.

    2014-06-01

    Simultaneous dual-radionuclide myocardial perfusion/innervation SPECT imaging can provide important information about the mismatch between scar tissue and denervated regions. The Siemens IQ-SPECT system developed for cardiac imaging uses a multifocal SMARTZOOM collimator to achieve a four-fold sensitivity for the cardiac region, compared to a typical parallel-hole low-energy high-resolution collimator, but without the data truncation that can result with conventional converging-beam collimators. The increased sensitivity allows shorter image acquisition times or reduced patient dose, making IQ-SPECT ideal for simultaneous dual-radionuclide SPECT, where reduced administrated activity is desirable in order to reduce patient radiation exposure. However, crosstalk is a major factor affecting the image quality in dual-radionuclide imaging. In this work we developed a model-based method that can estimate and compensate for the crosstalk in IQ-SPECT data. The crosstalk model takes into account interactions in the object and collimator-detector system. Scatter in the object was modeled using the effective source scatter estimation technique (ESSE), previously developed to model scatter with parallel-hole collimators. The geometric collimator-detector response was analytically modeled in the IQ-SPECT projector. The estimated crosstalk was then compensated for in an iterative reconstruction process. The new method was validated with data from both Monte Carlo simulations and physical phantom experiments. The results showed that the estimated crosstalk was in good agreement with simulated and measured results. After model-based compensation the images from simultaneous dual-radionuclide acquisitions were similar in quality to those from single-radionuclide acquisitions that did not have crosstalk contamination. The proposed model-based method can be used to improve simultaneous dual-radionuclide images acquired using IQ-SPECT. This work also demonstrates that ESSE scatter

  12. Design and development of MR-compatible SPECT systems for simultaneous SPECT-MR imaging of small animals

    NASA Astrophysics Data System (ADS)

    Tsui, Benjamin M. W.; Hugg, James W.; Xu, Jingyan; Chen, Si; Meier, Dirk; Edelstein, William; El-Sharkawy, Abdel; Wagenaar, Douglas J.; Patt, Bradley E.

    2011-03-01

    We describe a continuing design and development of MR-compatible SPECT systems for simultaneous SPECT-MR imaging of small animals. A first generation prototype SPECT system was designed and constructed to fit inside a MRI system with a gradient bore inner diameter of 12 cm. It consists of 3 angularly offset rings of 8 detectors (1"x1", 16x16 pixels MR-compatible solid-state CZT). A matching 24-pinhole collimator sleeve, made of a tungsten-compound, provides projections from a common FOV of ~25 mm. A birdcage RF coil for MRI data acquisition surrounds the collimator. The SPECT system was tested inside a clinical 3T MRI system. Minimal interference was observed on the simultaneously acquired SPECT and MR images. We developed a sparse-view image reconstruction method based on accurate modeling of the point response function (PRF) of each of the 24 pinholes to provide artifact-free SPECT images. The stationary SPECT system provides relatively low resolution of 3-5 mm but high geometric efficiency of 0.5- 1.2% for fast dynamic acquisition, demonstrated in a SPECT renal kinetics study using Tc-99m DTPA. Based on these results, a second generation prototype MR-compatible SPECT system with an outer diameter of 20 cm that fits inside a mid-sized preclinical MRI system is being developed. It consists of 5 rings of 19 CZT detectors. The larger ring diameter allows the use of optimized multi-pinhole collimator designs, such as high system resolution up to ~1 mm, high geometric efficiency, or lower system resolution without collimator rotation. The anticipated performance of the new system is supported by simulation data.

  13. Breast cancer axillary lymph node metastasis detection by a high-resolution dedicated breast camera: a comparative study with SPECT and pinhole SPECT.

    PubMed

    Spanu, Angela; Chessa, Francesca; Sanna, Daniela; Cottu, Pierina; Manca, Alessandra; Nuvoli, Susanna; Madeddu, Giuseppe

    2007-12-01

    We evaluated the usefulness of (99m)Tc-tetrofosmin planar scintigraphy acquired with a high-resolution (HR) dedicated breast camera in comparison with conventional single-photon emission computed tomography (SPECT) and pinhole-SPECT (P-SPECT) in breast cancer (BC) axillary lymph node metastasis detection in a consecutive series of 76 BC patients, 28 of whom had axillary lymph node metastases, including 9 positive at clinical examination. HR planar scintigraphy was true positive in only 7 patients with >3 palpable metastases (sensitivity: 25%), while SPECT was true positive in 23 of 28 cases (sensitivity: 82.1%) and P-SPECT in 25 of 28 (sensitivity: 89.3%). SPECT was false negative in 5 patients with nonpalpable SPECT was false negative in the latter 2 cases, and in another of the cases, false negative at SPECT with one macrometastatic node. Neither planar nor SPECT had false-positive findings (specificity: 100%), while P-SPECT had two (specificity: 95.8%). P-SPECT presented the best resolution in showing the metastatic nodes and was the only procedure able to define the number of involved nodes, thus delivering important prognostic information. HR planar scintigraphy appears an ineffective diagnostic tool in BC axillary lymph node metastasis detection, only succeeding in identifying palpable and >3 metastatic nodes. SPECT should be preferred, significantly improving the sensitivity of planar scintigraphy, especially when using a pinhole collimator.

  14. Three-Dimensional Dosimetric Analysis and Quantitative Bremsstrahlung Spect Imaging for Treatment of Non-Resectable Pancreatic Cancer Using Colloidal PHOSPHORUS-32.

    NASA Astrophysics Data System (ADS)

    Parsai, E. Ishmael

    1995-01-01

    Current methods of calculating absorbed dose in tissue from beta emitting radiopharmaceuticals yield only estimates of the average dose and cannot be used for dose mapping of bremsstrahlung SPECT images. The present work describes a clinically applicable methodology that can be used to determine the 3-D absorbed dose distribution from bremsstrahlung SPECT images for patients undergoing infusional brachytherapy. The radiopharmaceutical used in this study was colloidal P-32; however, other beta emitters can be used with this method. Calibration curves were generated from phantom studies to determine the activity per voxel from the attenuation corrected measured counts per voxel. The cumulative activity at each voxel position was converted to dose (Gy) using a Monte Carlo based P -32 point dose kernel calculation in water. Two-dimensional isodose distributions then were generated and projected on the reconstructed SPECT slices. This technique was further extended to calculate the quantitative dose for the entire volume and iso-surface dose distributions were generated in 3-D from bremsstrahlung SPECT data. In addition, to calculate the dose rate or accumulated dose at any depth from a given activity, a computer program based on the modified Loevinger point function was developed. This program calculates the dose in two ways: (1) through a closed solution for the spherical geometry by integration of the function over small spherical volumes, or (2) by applying the revised parameters of the modified Loevinger function. A practical and clinically feasible technique was developed for 3-D image co-registration between CT and SPECT for direct anatomic confirmation of the correlation between the region of the P-32 activity distribution and the anatomic site of injection. The method provides the correlation of the body contours obtained from bremsstrahlung SPECT data with corresponding contours from CT. A 3-D surface was first generated by mapping the iso-counts in the SPECT

  15. Performance evaluation of advanced industrial SPECT system with diverging collimator.

    PubMed

    Park, Jang Guen; Jung, Sung-Hee; Kim, Jong Bum; Moon, Jinho; Yeom, Yeon Soo; Kim, Chan Hyeong

    2014-12-01

    An advanced industrial SPECT system with 12-fold-array diverging collimator was developed for flow visualization in industrial reactors and was discussed in the previous study. The present paper describes performance evaluation of the SPECT system under both static- and dynamic- flow conditions. Under static conditions, the movement of radiotracer inside the test reactor was compared with that of color tracer (blue ink) captured with a high-speed camera. The comparison of the reconstructed images obtained with the radiotracer and the SPECT system showed fairly good agreement with video-frames of the color tracer obtained with the camera. Based on the results of the performance evaluation, it is concluded that the SPECT system is suitable for investigation and visualization of flows in industrial flow reactors.

  16. Performance evaluation of advanced industrial SPECT system with diverging collimator.

    PubMed

    Park, Jang Guen; Jung, Sung-Hee; Kim, Jong Bum; Moon, Jinho; Yeom, Yeon Soo; Kim, Chan Hyeong

    2014-12-01

    An advanced industrial SPECT system with 12-fold-array diverging collimator was developed for flow visualization in industrial reactors and was discussed in the previous study. The present paper describes performance evaluation of the SPECT system under both static- and dynamic- flow conditions. Under static conditions, the movement of radiotracer inside the test reactor was compared with that of color tracer (blue ink) captured with a high-speed camera. The comparison of the reconstructed images obtained with the radiotracer and the SPECT system showed fairly good agreement with video-frames of the color tracer obtained with the camera. Based on the results of the performance evaluation, it is concluded that the SPECT system is suitable for investigation and visualization of flows in industrial flow reactors. PMID:25169132

  17. A systematic review of molecular imaging (PET and SPECT) in autism spectrum disorder: current state and future research opportunities.

    PubMed

    Zürcher, Nicole R; Bhanot, Anisha; McDougle, Christopher J; Hooker, Jacob M

    2015-05-01

    Non-invasive positron emission tomography (PET) and single-photon emission computed tomography (SPECT) are techniques used to quantify molecular interactions, biological processes and protein concentration and distribution. In the central nervous system, these molecular imaging techniques can provide critical insights into neurotransmitter receptors and their occupancy by neurotransmitters or drugs. In recent years, there has been an increase in the number of studies that have investigated neurotransmitters in autism spectrum disorder (ASD), while earlier studies mostly focused on cerebral blood flow and glucose metabolism. The underlying and contributing mechanisms of ASD are largely undetermined and ASD diagnosis relies on the behavioral phenotype. Discovery of biochemical endophenotypes would represent a milestone in autism research that could potentially lead to ASD subtype stratification and the development of novel therapeutic drugs. This review characterizes the prior use of molecular imaging by PET and SPECT in ASD, addresses methodological challenges and highlights areas of future opportunity for contributions from molecular imaging to understand ASD pathophysiology.

  18. ACR testing of a dedicated head SPECT unit.

    PubMed

    Sensakovic, William F; Hough, Matthew C; Kimbley, Elizabeth A

    2014-07-08

    Physics testing necessary for program accreditation is rigorously defined by the ACR. This testing is easily applied to most conventional SPECT systems based on gamma camera technology. The inSPira HD is a dedicated head SPECT system based on a rotating dual clamshell design that acquires data in a dual-spiral geometry. The unique geometry and configuration force alterations of the standard ACR physics testing protocol. Various tests, such as intrinsic planar uniformity and/or resolution, do not apply. The Data Spectrum Deluxe Phantom used for conventional SPECT testing cannot fit in the inSPira HD scanner bore, making (currently) unapproved use of the Small Deluxe SPECT Phantom necessary. Matrix size, collimator type, scanning time, reconstruction method, and attenuation correction were all varied from the typically prescribed ACR instructions. Visible spheres, sphere contrast, visible rod groups, uniformity, and root mean square (RMS) noise were measured. The acquired SPECT images surpassed the minimum ACR requirements for both spatial resolution (9.5 mm spheres resolved) and contrast (6.4 mm rod groups resolved). Sphere contrast was generally high. Integral uniformity was 4% and RMS noise was 1.7%. Noise appeared more correlated than in images from a conventional SPECT scanner. Attenuation-corrected images produced from direct CT scanning of the phantom and a manufacturer supplied model of the phantom demonstrated negligible differences.

  19. A prospective comparison of rubidium-82 PET and thallium-201 SPECT myocardial perfusion imaging utilizing a single dipyridamole stress in the diagnosis of coronary artery disease

    SciTech Connect

    Go, R.T.; Marwick, T.H.; MacIntyre, W.J.; Saha, G.B.; Neumann, D.R.; Underwood, D.A.; Simpfendorfer, C.C. )

    1990-12-01

    The purpose of the present study is to prospectively compare myocardial perfusion imaging with rubidium-82 ({sup 82}Rb) by positron emission tomography (PET) with thallium-201 ({sup 201}Tl) imaging by single-photon emission tomography (SPECT) by recording both studies with a single dipyridamole handgrip stress, and reading both sets of images with the same display technique. In a series of 202 patients with previous coronary arteriography, the sensitivity, specificity, and accuracy of {sup 82}Rb PET were 93%, 78%, and 90% and for {sup 201}Tl SPECT 76%, 80%, and 77%, respectively. When 70 patients with previous therapeutic interventions were excluded, the remaining 132 patients showed a sensitivity, specificity, and accuracy of 95%, 82% and 92% for {sup 82}Rb PET and 79%, 76%, and 78% for {sup 201}Tl SPECT. The improved contrast resolution of PET resulted in markedly superior images and a more confident identification of defects.

  20. A multiresolution restoration method for cardiac SPECT imaging.

    PubMed

    Franquiz, J M; Shukla, S

    1998-12-01

    nuclear medicine restoration filters. In addition, the method is easy to implement using DFT techniques and potentially can be extended to noniterative spatially shift-invariant restorations in SPECT.

  1. Development of a Germanium Small-Animal SPECT System

    PubMed Central

    Johnson, Lindsay C.; Ovchinnikov, Oleg; Shokouhi, Sepideh; Peterson, Todd E.

    2015-01-01

    Advances in fabrication techniques, electronics, and mechanical cooling systems have given rise to germanium detectors suitable for biomedical imaging. We are developing a small-animal SPECT system that uses a double-sided Ge strip detector. The detector’s excellent energy resolution may help to reduce scatter and simplify processing of multi-isotope imaging, while its ability to measure depth of interaction has the potential to mitigate parallax error in pinhole imaging. The detector’s energy resolution is <1% FWHM at 140 keV and its spatial resolution is approximately 1.5 mm FWHM. The prototype system described has a single-pinhole collimator with a 1-mm diameter and a 70-degree opening angle with a focal length variable between 4.5 and 9 cm. Phantom images from the gantry-mounted system are presented, including the NEMA NU-2008 phantom and a hot-rod phantom. Additionally, the benefit of energy resolution is demonstrated by imaging a dual-isotope phantom with 99mTc and 123I without cross-talk correction. PMID:26755832

  2. Cerebral hypoperfusion detected by SPECT in patients with systemic lupus erythematosus is related to clinical activity and cumulative tissue damage.

    PubMed

    López-Longo, F J; Carol, N; Almoguera, M I; Olazarán, J; Alonso-Farto, J C; Ortega, A; Monteagudo, I; González, C Manuel; Carreño, L

    2003-01-01

    Cerebral single-photon emission computed tomography (SPECT) is a sensitive technique for the detection of central nervous system (CNS) involvement in systemic lupus erythematosus (SLE). The objective was to determine whether a relationship exists between cerebral hypoperfusion as detected by cerebral SPECT, cumulative tissue damage and the clinical activity of SLE. Cerebral technetium-99m-L,L-ethyl cysteinate dimer (99mTc-ECD) SPECT was performed in two groups of patients: 10 women with SLE (Group A) who had no previous history of major neuropsychiatric (NPS) manifestations and no minor NPS symptoms in the last six months, and 57 unselected women with SLE (Group B). In the same week that SPECT was performed, the SLE disease activity index (SLEDAI), SLICC/ACR damage index, native anti-DNA antibodies (ELISA) and erythrocyte sedimentation rate (ESR) were determined. In Group A, cerebral SPECT showed moderate or severe hypoperfusion (abnormal SPECT) in five patients without NPS symptoms, unrelated to age (mean 24.8 versus 27.8 years) or disease duration (mean 6.8 versus 9 years). Patients with significant cerebral hypoperfusion had greater clinical disease activity (mean SLEDAI 13.6 versus 7.6) (SLEDAI > 7 in 5/5 versus 1/5; Fisher: 0.023; OR: 33; 95% CI: 2.3-469.8) and ESR (mean 43.6 versus 9.8; P < 0.05). In Group B, the mean age of the 57 unselected women with SLE was 37 years (SD 6.3) and the mean duration of the disease was 9.7 years (SD 6.3). Cerebral SPECT revealed normal perfusion or mild hypoperfusion (normal SPECT) in 30 patients (52.6%), and moderate or severe hypoperfusion in 27 (47.4%). Hypoperfusion was unrelated to age, duration of SLE or concentrations of anti-DNA antibodies and C3 and C4 fractions. Patients with significant cerebral hypoperfusion had more active clinical disease (mean SLEDAI 13.92; SD 8.44 versus 4.56; SD 4.15) (Mann-Whitney, P < 0.005), more cumulative tissue damage (mean SLICC 2.66; SD 2.84 versus 1.03; SD 1.51) (Mann-Whitney, P = 0

  3. The development and initial evaluation of a realistic simulated SPECT dataset with simultaneous respiratory and cardiac motion for gated myocardial perfusion SPECT

    NASA Astrophysics Data System (ADS)

    Lee, Taek-Soo; Tsui, Benjamin M. W.

    2015-02-01

    We developed a realistic simulation dataset for simultaneous respiratory and cardiac (R&C) gated SPECT/CT using the 4D NURBS-based Cardiac-Torso (NCAT) Phantom and Monte Carlo simulation methods, and evaluated it for a sample application study. The 4D NCAT phantom included realistic respiratory motion and beating heart motion based on respiratory gated CT and cardiac tagged MRI data of normal human subjects. To model the respiratory motion, a set of 24 separate 3D NCAT phantoms excluding the heart was generated over a respiratory cycle. The beating heart motion was modeled separately with 48 frames per cardiac cycle for each of the 24 respiratory phases. The resultant set of 24  ×  48 3D NCAT phantoms provides a realistic model of a normal human subject at different phases of combined R&C motions. An almost noise-free SPECT projection dataset for each of the 1152 3D NCAT phantoms was generated using Monte Carlo simulation techniques and the radioactivity uptake distribution of 99mTc sestamibi in different organs. By grouping and summing the separate projection datasets, separate or simultaneous R&C gated acquired data with different gating schemes could be simulated. In the initial evaluation, we combined the projection datasets into ungated, 6 respiratory-gates only, 8 cardiac-gates only, and combined 6 respiratory-gates & 8 cardiac-gates projection datasets. Each dataset was reconstructed using 3D OS-EM without and with attenuation correction using the averaged and respiratory-gated attenuation maps, and the resulting reconstructed images were compared. These results were used to demonstrate the effects of R&C motions and the reduction of image artifact due to R&C motions by gating and attenuation corrections. We concluded that the realistic 4D NCAT phantom and Monte Carlo simulated SPECT projection datasets with R&C motions are powerful tools in the study of the effects of R&C motions, as well as in the development of R&C gating schemes and motion

  4. The Development and Initial Evaluation of a Realistic Simulated SPECT Dataset with Simultaneous Respiratory and Cardiac Motion for Gated Myocardial Perfusion SPECT

    PubMed Central

    Lee, Taek-Soo; Tsui, Benjamin M. W.

    2015-01-01

    We developed a realistic simulation dataset for simultaneous respiratory and cardiac (R&C) gated SPECT/CT using the 4D NURBS-based Cardiac-Torso (NCAT) Phantom and Monte Carlo simulation methods, and evaluated it for a sample application study. The 4D NCAT phantom included realistic respiratory motion and beating heart motion based on respiratory gated CT and cardiac tagged MRI data of normal human subjects. To model the respiratory motion, a set of 24 separate 3D NCAT phantoms excluding the heart was generated over a respiratory cycle. The beating heart motion was modelled separately with 48 frames per cardiac cycle for each of the 24 respiratory phases. The resultant set of 24×48 3D NCAT phantoms provides a realistic model of a normal human subject at different phases of combined R&C motions. An almost noise-free SPECT projection dataset for each of the 1,152 3D NCAT phantoms was generated using Monte Carlo simulation techniques and the radioactivity uptake distribution of 99mTc sestamibi in different organs. By grouping and summing the separate projection datasets, separate or simultaneous R&C gated acquired data with different gating schemes could be simulated. In the initial evaluation, we combined the projection datasets into no gating, 6 respiratory-gates only, 8 cardiac-gates only, and combined 6 respiratory-gates & 8 cardiac-gates projection datasets. Each dataset was reconstructed using 3D OS-EM without and with attenuation correction using the averaged and respiratory-gated attenuation maps, and the resulting reconstructed images were compared. These results were used to demonstrate the effects of R&C motions and the reduction of image artifact due to R&C motions by gating and attenuation corrections. We concluded that the realistic 4D NCAT phantom and Monte Carlo simulated SPECT projection datasets with R&C motions are powerful tools in the study of the effects of R&C motions, as well as in the development of R&C gating schemes and motion correction

  5. The development and initial evaluation of a realistic simulated SPECT dataset with simultaneous respiratory and cardiac motion for gated myocardial perfusion SPECT.

    PubMed

    Lee, Taek-Soo; Tsui, Benjamin M W

    2015-02-21

    We developed a realistic simulation dataset for simultaneous respiratory and cardiac (R&C) gated SPECT/CT using the 4D NURBS-based Cardiac-Torso (NCAT) Phantom and Monte Carlo simulation methods, and evaluated it for a sample application study. The 4D NCAT phantom included realistic respiratory motion and beating heart motion based on respiratory gated CT and cardiac tagged MRI data of normal human subjects. To model the respiratory motion, a set of 24 separate 3D NCAT phantoms excluding the heart was generated over a respiratory cycle. The beating heart motion was modeled separately with 48 frames per cardiac cycle for each of the 24 respiratory phases. The resultant set of 24  ×  48 3D NCAT phantoms provides a realistic model of a normal human subject at different phases of combined R&C motions. An almost noise-free SPECT projection dataset for each of the 1152 3D NCAT phantoms was generated using Monte Carlo simulation techniques and the radioactivity uptake distribution of (99m)Tc sestamibi in different organs. By grouping and summing the separate projection datasets, separate or simultaneous R&C gated acquired data with different gating schemes could be simulated. In the initial evaluation, we combined the projection datasets into ungated, 6 respiratory-gates only, 8 cardiac-gates only, and combined 6 respiratory-gates & 8 cardiac-gates projection datasets. Each dataset was reconstructed using 3D OS-EM without and with attenuation correction using the averaged and respiratory-gated attenuation maps, and the resulting reconstructed images were compared. These results were used to demonstrate the effects of R&C motions and the reduction of image artifact due to R&C motions by gating and attenuation corrections. We concluded that the realistic 4D NCAT phantom and Monte Carlo simulated SPECT projection datasets with R&C motions are powerful tools in the study of the effects of R&C motions, as well as in the development of R&C gating schemes and motion

  6. Three-dimensional SPECT imaging with LaBr3:Ce scintillator for characterization of nuclear waste

    NASA Astrophysics Data System (ADS)

    Roy, Tushar; Ratheesh, Jilju; Sinha, Amar

    2014-01-01

    Characterization of nuclear waste in terms of radioactivity distribution is important not only for their safe disposal but also for nuclear material accounting. Single Photon Emission Computed Tomography (SPECT) provides a non-invasive technique for the characterization and activity distribution of the gamma-emitting sources in a matrix. Sodium iodide scintillators, which are most commonly used, suffer from poor energy resolution and do not provide accurate peak discrimination for radioisotopes like 239Pu which have overlapping peaks. Cerium-activated lanthanum bromide (LaBr3:Ce) scintillators have better energy resolution and provide better peak discrimination. In this paper, experimental studies using LaBr3:Ce for 3D SPECT imaging of dummy waste drum has been discussed. The reconstruction has been done using the Filtered Backprojection scheme with attenuation compensation based on Novikov's inversion formula.

  7. Dual SPECT/MR imaging in small animal

    NASA Astrophysics Data System (ADS)

    Breton, E.; Choquet, P.; Goetz, C.; Kintz, J.; Erbs, P.; Rooke, R.; Constantinesco, A.

    2007-02-01

    ObjectiveTo demonstrate the feasibility of SPECT/MRI in small animal using a dual device. Material and methodsA small animal pinhole camera (1.5 mm in diameter) coupled together with a dedicated low-field (0.1 T) small MR imager (imaging volume of 10×10×6 cm 3) was used. SPECT consisted of acquiring 48 projections after intra-venous injections of 0.2 ml and 700 MBq of 99mTc-Sestamibi and was immediately followed by MRI with 3D isotropic T 1 and T 2 weighted imaging sequences. Two adult Swiss nude mice with stereotaxic brain implanted human glioblastoma cells and maintained under isoflurane 1.5% and air 0.3 L min -1 in a warmed-up and non-magnetic imaging cell for both modalities were used in this study. ResultsFusion images of SPECT/low-field MRI were obtained with isotropic voxel resolutions of 1×1×1 mm 3 for SPECT and 0.5×0.5×0.5 mm 3 for MRI. Total acquisition time for both imaging modalities was 2.5 h. ConclusionA low magnetic field strength of 0.1 T is a potential solution for a small animal dual imaging device combining pinhole SPECT and MRI in a single machine.

  8. Multimodality tomographic scintimammography with PET, PECI, and SPECT: initial evaluation

    NASA Astrophysics Data System (ADS)

    Krol, Andrzej; Feiglin, David H.; Thomas, Frank D.; Hellwig, Bradford J.; Gagne, George M.

    2002-04-01

    We compared tomographic scintimammography performed using single photon emission computed tomography (SPECT), positron emission coincidence imaging (PECI) and positron emission tomography (PET). A female thorax phantom was used. Activities of the myocardium, thorax and breasts were adjusted to emulate the count rate observed with patients. Hollow plastic spheres, imitating hot lesions (1.5-20ml), filled with radioactive saline were inserted in the center of each breast. Specific activities of internal organs were adjusted to emulate the count rate observed with patients. SPECT data were acquired with Tc-99m using gamma cameras with NaI(Tl) detectors. A modified FBP (CODE) reconstruction algorithm was used to render SPECT tomographic images. PECI (Siemens E.CAM with NaI(Tl)) and PET (GE Advance with BGO) data were acquired using F-18 FDG. Vendor supplied reconstruction algorithms were used. The reconstructed hot lesions contrast and resolution were investigated. Image quality obtained can be ranked as follows: (1) PET(BGO), (2) PECI(NaI), (3) SPECT(NaI) In conclusion, assuming comparable uptake values of Tc-99m-sestamibi and F-18 FDG, PET seems to be a superior methodology in visualization of breast lesion as compared to SPECT and PECI. All these tomographic methods appear to be promising adjunct to x-ray mammography in difficult to interpret cases.

  9. Recent developments and future prospects of SPECT myocardial perfusion imaging.

    PubMed

    Zaman, Maseeh Uz; Hashmi, Ibrahim; Fatima, Nosheen

    2010-10-01

    Myocardial perfusion SPECT imaging is the most commonly performed functional imaging for assessment of coronary artery disease. High diagnostic accuracy and incremental prognostic value are the major benefits while suboptimal spatial resolution and significant radiation exposure are the main limitations. Its ability to detect hemodynamic significance of lesions seen on multidetector CT angiogram (MDCTA) has paved the path for a successful marriage between anatomical and functional imaging modalities in the form of hybrid SPECT/MDCTA system. In recent years, there have been enormous efforts by industry and academia to develop new SPECT imaging systems with better sensitivity, resolution, compact design and new reconstruction algorithms with ability to improve image quality and resolution. Furthermore, expected arrival of Tc-99m-labeled deoxyglucose in next few years would further strengthen the role of SPECT in imaging hibernating myocardium. In view of these developments, it seems that SPECT would enjoy its pivotal role in spite of major threat to be replaced by fluorine-18-labeled positron emission tomography perfusion and glucose metabolism imaging agents. PMID:20652774

  10. A 3D image analysis tool for SPECT imaging

    NASA Astrophysics Data System (ADS)

    Kontos, Despina; Wang, Qiang; Megalooikonomou, Vasileios; Maurer, Alan H.; Knight, Linda C.; Kantor, Steve; Fisher, Robert S.; Simonian, Hrair P.; Parkman, Henry P.

    2005-04-01

    We have developed semi-automated and fully-automated tools for the analysis of 3D single-photon emission computed tomography (SPECT) images. The focus is on the efficient boundary delineation of complex 3D structures that enables accurate measurement of their structural and physiologic properties. We employ intensity based thresholding algorithms for interactive and semi-automated analysis. We also explore fuzzy-connectedness concepts for fully automating the segmentation process. We apply the proposed tools to SPECT image data capturing variation of gastric accommodation and emptying. These image analysis tools were developed within the framework of a noninvasive scintigraphic test to measure simultaneously both gastric emptying and gastric volume after ingestion of a solid or a liquid meal. The clinical focus of the particular analysis was to probe associations between gastric accommodation/emptying and functional dyspepsia. Employing the proposed tools, we outline effectively the complex three dimensional gastric boundaries shown in the 3D SPECT images. We also perform accurate volume calculations in order to quantitatively assess the gastric mass variation. This analysis was performed both with the semi-automated and fully-automated tools. The results were validated against manual segmentation performed by a human expert. We believe that the development of an automated segmentation tool for SPECT imaging of the gastric volume variability will allow for other new applications of SPECT imaging where there is a need to evaluate complex organ function or tumor masses.

  11. Dopamine D2 receptor status assessed by IBZM SPECT - A sensitive indicator for cerebral hypoxia

    SciTech Connect

    Tatsch, K.; Schwarz, J.; Welz, A.

    1995-05-01

    The striatum is highly sensitive to tissue hypoxia. Thus, it may be suggested that cerebral hypoxia could affect the integrity of the striatal receptor system. Purpose of the current SPECT investigations with IBZM was to evaluate whether hypoxic conditions cause detectable changes in the D2 receptor status. 25 controls and 30 pts with history of cerebral hypoxia (resuscitation after cardiac arrest: n=19, CABG surgery under cardiopulmonary bypass: n=11) were investigated with SPECT 2h p.i. of 185 MBq I-123 IBZM. For semiquant, evaluation transverse slices corrected for attenuation were used to calculate striatal to frontal cortex (S/FC) ratios. In 13/19 pts with cerebral hypoxia due to cardiac arrest IBZM binding was severely reduced after successful resuscitation. 7 died, 5 were in a vegetative state, 1 remained severely disabled. In 6/19 S/FC ratios were normal/mildly reduced, 2 of them had a good outcome, 4 were moderatley disabled. In pts with CABG IBZM binding was preoperatively normal. After hypoxia due to cardiac surgery striatal S/FC ratios decreased slightly, persisting on this level even 6 months after surgery. Neuropsychological/psychiatric testing showed only minor or transient changes in this group of patients. The striatal D2 receptor status seems to be a sensitive indicator for cerebral hypoxia. After hypoxia due to cardiac arrest IBZM results well correlate (in contrast to morphological or SEP findings) with the clinical outcome and thus may serve as early predictor of the individual prognosis. The moderate decline in IBZM binding following CABG surgery suggests mild cerebral hypoxia despite of protective hypothermia. Sensitively indicating cerebral hypoxia changes in the D2 receptor status assessed by IBZM SPECT may serve as a valuable diagnostic tool for testing neuroprotective drugs or modified surgical techniques.

  12. Discriminating among degenerative parkinsonisms using advanced (123)I-ioflupane SPECT analyses.

    PubMed

    Badoud, Simon; Van De Ville, Dimitri; Nicastro, Nicolas; Garibotto, Valentina; Burkhard, Pierre R; Haller, Sven

    2016-01-01

    (123)I-ioflupane single photon emission computed tomography (SPECT) is a sensitive and well established imaging tool in Parkinson's disease (PD) and atypical parkinsonian syndromes (APS), yet a discrimination between PD and APS has been considered inconsistent at least based on visual inspection or simple region of interest analyses. We here reappraise this issue by applying advanced image analysis techniques to separate PD from the various APS. This study included 392 consecutive patients with degenerative parkinsonism undergoing (123)I-ioflupane SPECT at our institution over the last decade: 306 PD, 24 multiple system atrophy (MSA), 32 progressive supranuclear palsy (PSP) and 30 corticobasal degeneration (CBD) patients. Data analysis included voxel-wise univariate statistical parametric mapping and multivariate pattern recognition using linear discriminant classifiers. MSA and PSP showed less ioflupane uptake in the head of caudate nucleus relative to PD and CBD, yet there was no difference between MSA and PSP. CBD had higher uptake in both putamen relative to PD, MSA and PSP. Classification was significant for PD versus APS (AUC 0.69, p < 0.05) and between APS subtypes (MSA vs CBD AUC 0.80, p < 0.05; MSA vs PSP AUC 0.69 p < 0.05; CBD vs PSP AUC 0.69 p < 0.05). Both striatal and extra-striatal regions contain classification information, yet the combination of both regions does not significantly improve classification accuracy. PD, MSA, PSP and CBD have distinct patterns of dopaminergic depletion on (123)I-ioflupane SPECT. The high specificity of 84-90% for PD versus APS indicates that the classifier is particularly useful for confirming APS cases. PMID:27489771

  13. Quantitation of renal uptake of technetium-99m DMSA using SPECT

    SciTech Connect

    Groshar, D.; Frankel, A.; Iosilevsky, G.; Israel, O.; Moskovitz, B.; Levin, D.R.; Front, D.

    1989-02-01

    Quantitative single photon emission computed tomography (SPECT) methodology based on calibration with kidney phantoms has been applied for the assessment of renal uptake of (/sup 99m/Tc)DMSA in 25 normals; 16 patients with a single normal kidney; 30 patients with unilateral nephropathy; and 17 patients with bilateral nephropathy. An excellent correlation (r = 0.99, s.e.e. = 152) was found between SPECT measured concentration and actual concentration in kidney phantoms. Kidney uptake at 6 hr after injection in normals was 20.0% +/- 4.6% for the left and 20.8% +/- 4.4% for the right. Patients with unilateral nephropathy had a statistically significant (p less than 0.001) low uptake in the diseased kidney (7.0% +/- 4.7%), but the contralateral kidney uptake did not differ from the normal group (20.0% +/- 7.0%). The method was especially useful in patients with bilateral nephropathy. Significantly (p less than 0.001) decreased uptake was found in both kidneys (5.1% +/- 3.4% for the left and 6.7% +/- 4.2% for the right). The total kidney uptake (right and left) in this group showed to be inversely correlated (r = 0.83) with serum creatinine. The uptake of (/sup 99m/Tc)DMSA in single normal kidney was higher (p less than 0.001) than in a normal kidney (34.7% +/- 11.9%), however, it was lower than the total absolute uptake (RT + LT = 41.5% +/- 8.8%) in the normal group. The results indicate that SPECT is a reliable and reproducible technique to quantitate absolute kidney uptake of (/sup 99m/Tc)DMSA.

  14. Simulation of realistic abnormal SPECT brain perfusion images: application in semi-quantitative analysis

    NASA Astrophysics Data System (ADS)

    Ward, T.; Fleming, J. S.; Hoffmann, S. M. A.; Kemp, P. M.

    2005-11-01

    Simulation is useful in the validation of functional image analysis methods, particularly when considering the number of analysis techniques currently available lacking thorough validation. Problems exist with current simulation methods due to long run times or unrealistic results making it problematic to generate complete datasets. A method is presented for simulating known abnormalities within normal brain SPECT images using a measured point spread function (PSF), and incorporating a stereotactic atlas of the brain for anatomical positioning. This allows for the simulation of realistic images through the use of prior information regarding disease progression. SPECT images of cerebral perfusion have been generated consisting of a control database and a group of simulated abnormal subjects that are to be used in a UK audit of analysis methods. The abnormality is defined in the stereotactic space, then transformed to the individual subject space, convolved with a measured PSF and removed from the normal subject image. The dataset was analysed using SPM99 (Wellcome Department of Imaging Neuroscience, University College, London) and the MarsBaR volume of interest (VOI) analysis toolbox. The results were evaluated by comparison with the known ground truth. The analysis showed improvement when using a smoothing kernel equal to system resolution over the slightly larger kernel used routinely. Significant correlation was found between effective volume of a simulated abnormality and the detected size using SPM99. Improvements in VOI analysis sensitivity were found when using the region median over the region mean. The method and dataset provide an efficient methodology for use in the comparison and cross validation of semi-quantitative analysis methods in brain SPECT, and allow the optimization of analysis parameters.

  15. Perturbative refinement of the geometric calibration in pinhole SPECT.

    PubMed

    Defrise, Michel; Vanhove, Christian; Nuyts, Johan

    2008-02-01

    The paper investigates the geometric calibration of a rotating gamma camera for pinhole (PH) single photon emission computed tomography (SPECT) imaging. Most calibration methods previously applied in PH-SPECT assume that the motion of the camera around the object belongs to a well-defined class described by a small number of geometric parameters, for instance seven parameters for a circular acquisition with a single pinhole camera. The proposed new method refines an initial parametric calibration by applying to each position of the camera a rigid body transformation that is determined to improve the fit between the measured and calculated projections of the calibration sources. A stable estimate of this transformation can be obtained with only three calibration sources by linearizing the equations around the position estimated by the initial parametric calibration. The performance of the method is illustrated using simulated and measured micro-SPECT data.

  16. Determination of left ventricular mass through SPECT imaging

    NASA Astrophysics Data System (ADS)

    Zárate-Morales, A.; Rodríguez-Villafuerte, M.; Martínez-Rodríguez, F.; Arévila-Ceballos, N.

    1998-08-01

    An edge detection algorithm has been applied to estimate left ventricular (LV) mass from single photon emission computed tomography (SPECT) thallium-201 images. The algorithm was validated using SPECT images of a phantom. The algorithm was applied to 20 patient studies from the Hospital de Cardiologia, Centro Médico Nacional Siglo XXI. Left ventricular masses derived from the stress and redistribution studies were highly correlated (r=0.96). The average LV masses obtained were 162±37 g and 169±34 g in the redistribution and stress studies, respectively.

  17. Evaluation of Mucociliary Clearance by Three Dimension Micro-CT-SPECT in Guinea Pig: Role of Bitter Taste Agonists

    PubMed Central

    Ortiz, Jose Luis; Ortiz, Amparo; Milara, Javier; Armengot, Miguel; Sanz, Celia; Compañ, Desamparados; Morcillo, Esteban; Cortijo, Julio

    2016-01-01

    Different image techniques have been used to analyze mucociliary clearance (MCC) in humans, but current small animal MCC analysis using in vivo imaging has not been well defined. Bitter taste receptor (T2R) agonists increase ciliary beat frequency (CBF) and cause bronchodilation but their effects in vivo are not well understood. This work analyzes in vivo nasal and bronchial MCC in guinea pig animals using three dimension (3D) micro-CT-SPECT images and evaluates the effect of T2R agonists. Intranasal macroaggreggates of albumin-Technetium 99 metastable (MAA-Tc99m) and lung nebulized Tc99m albumin nanocolloids were used to analyze the effect of T2R agonists on nasal and bronchial MCC respectively, using 3D micro-CT-SPECT in guinea pig. MAA-Tc99m showed a nasal mucociliary transport rate of 0.36 mm/min that was increased in presence of T2R agonist to 0.66 mm/min. Tc99m albumin nanocolloids were homogeneously distributed in the lung of guinea pig and cleared with time-dependence through the bronchi and trachea of guinea pig. T2R agonist increased bronchial MCC of Tc99m albumin nanocolloids. T2R agonists increased CBF in human nasal ciliated cells in vitro and induced bronchodilation in human bronchi ex vivo. In summary, T2R agonists increase MCC in vivo as assessed by 3D micro-CT-SPECT analysis. PMID:27723827

  18. Estimation of Rigid-Body and Respiratory Motion of the Heart From Marker-Tracking Data for SPECT Motion Correction

    PubMed Central

    Mukherjee, Joyeeta Mitra; McNamara, Joseph E.; Johnson, Karen L.; Dey, Joyoni; King, Michael A.

    2009-01-01

    Motion of patients undergoing cardiac SPECT perfusion imaging causes artifacts in the acquired images which may lead to difficulty in interpretation. Our work investigates a technique of obtaining patient motion estimates from retro-reflective markers on stretchy bands wrapped around the chest and abdomen of patients being imaged clinically. Motion signals obtained from the markers consist of at least two components, body motion (BM) and periodic motion (PM) due to respiration. We present a method for separating these components from the motion-tracking data of each marker, and then report a method for combining the BM estimated from chest markers to estimate the 6-degree-of-freedom (6-DOF) rigid-body motion (RBM) of the heart. Motion studies of volunteers and patients are used to evaluate the methods. Illustrative examples of the motion of the heart due to patient body movement and respiration (upward creep) are presented and compared to estimates of the motion of the heart obtained directly from SPECT data. Our motion-tracking method is seen to give reasonable agreement with the motion-estimates from the SPECT data while being considerably less noisy. PMID:20539825

  19. reSpect: software for identification of high and low abundance ion species in chimeric tandem mass spectra.

    PubMed

    Shteynberg, David; Mendoza, Luis; Hoopmann, Michael R; Sun, Zhi; Schmidt, Frank; Deutsch, Eric W; Moritz, Robert L

    2015-11-01

    Most shotgun proteomics data analysis workflows are based on the assumption that each fragment ion spectrum is explained by a single species of peptide ion isolated by the mass spectrometer; however, in reality mass spectrometers often isolate more than one peptide ion within the window of isolation that contribute to additional peptide fragment peaks in many spectra. We present a new tool called reSpect, implemented in the Trans-Proteomic Pipeline (TPP), which enables an iterative workflow whereby fragment ion peaks explained by a peptide ion identified in one round of sequence searching or spectral library search are attenuated based on the confidence of the identification, and then the altered spectrum is subjected to further rounds of searching. The reSpect tool is not implemented as a search engine, but rather as a post-search engine processing step where only fragment ion intensities are altered. This enables the application of any search engine combination in the iterations that follow. Thus, reSpect is compatible with all other protein sequence database search engines as well as peptide spectral library search engines that are supported by the TPP. We show that while some datasets are highly amenable to chimeric spectrum identification and lead to additional peptide identification boosts of over 30% with as many as four different peptide ions identified per spectrum, datasets with narrow precursor ion selection only benefit from such processing at the level of a few percent. We demonstrate a technique that facilitates the determination of the degree to which a dataset would benefit from chimeric spectrum analysis. The reSpect tool is free and open source, provided within the TPP and available at the TPP website. Graphical Abstract ᅟ.

  20. reSpect: software for identification of high and low abundance ion species in chimeric tandem mass spectra.

    PubMed

    Shteynberg, David; Mendoza, Luis; Hoopmann, Michael R; Sun, Zhi; Schmidt, Frank; Deutsch, Eric W; Moritz, Robert L

    2015-11-01

    Most shotgun proteomics data analysis workflows are based on the assumption that each fragment ion spectrum is explained by a single species of peptide ion isolated by the mass spectrometer; however, in reality mass spectrometers often isolate more than one peptide ion within the window of isolation that contribute to additional peptide fragment peaks in many spectra. We present a new tool called reSpect, implemented in the Trans-Proteomic Pipeline (TPP), which enables an iterative workflow whereby fragment ion peaks explained by a peptide ion identified in one round of sequence searching or spectral library search are attenuated based on the confidence of the identification, and then the altered spectrum is subjected to further rounds of searching. The reSpect tool is not implemented as a search engine, but rather as a post-search engine processing step where only fragment ion intensities are altered. This enables the application of any search engine combination in the iterations that follow. Thus, reSpect is compatible with all other protein sequence database search engines as well as peptide spectral library search engines that are supported by the TPP. We show that while some datasets are highly amenable to chimeric spectrum identification and lead to additional peptide identification boosts of over 30% with as many as four different peptide ions identified per spectrum, datasets with narrow precursor ion selection only benefit from such processing at the level of a few percent. We demonstrate a technique that facilitates the determination of the degree to which a dataset would benefit from chimeric spectrum analysis. The reSpect tool is free and open source, provided within the TPP and available at the TPP website. Graphical Abstract ᅟ. PMID:26419769

  1. reSpect: Software for Identification of High and Low Abundance Ion Species in Chimeric Tandem Mass Spectra

    NASA Astrophysics Data System (ADS)

    Shteynberg, David; Mendoza, Luis; Hoopmann, Michael R.; Sun, Zhi; Schmidt, Frank; Deutsch, Eric W.; Moritz, Robert L.

    2015-11-01

    Most shotgun proteomics data analysis workflows are based on the assumption that each fragment ion spectrum is explained by a single species of peptide ion isolated by the mass spectrometer; however, in reality mass spectrometers often isolate more than one peptide ion within the window of isolation that contribute to additional peptide fragment peaks in many spectra. We present a new tool called reSpect, implemented in the Trans-Proteomic Pipeline (TPP), which enables an iterative workflow whereby fragment ion peaks explained by a peptide ion identified in one round of sequence searching or spectral library search are attenuated based on the confidence of the identification, and then the altered spectrum is subjected to further rounds of searching. The reSpect tool is not implemented as a search engine, but rather as a post-search engine processing step where only fragment ion intensities are altered. This enables the application of any search engine combination in the iterations that follow. Thus, reSpect is compatible with all other protein sequence database search engines as well as peptide spectral library search engines that are supported by the TPP. We show that while some datasets are highly amenable to chimeric spectrum identification and lead to additional peptide identification boosts of over 30% with as many as four different peptide ions identified per spectrum, datasets with narrow precursor ion selection only benefit from such processing at the level of a few percent. We demonstrate a technique that facilitates the determination of the degree to which a dataset would benefit from chimeric spectrum analysis. The reSpect tool is free and open source, provided within the TPP and available at the TPP website.

  2. reSpect: Software for Identification of High and Low Abundance Ion Species in Chimeric Tandem Mass Spectra

    PubMed Central

    Shteynberg, David; Mendoza, Luis; Hoopmann, Michael R.; Sun, Zhi; Schmidt, Frank; Deutsch, Eric W.; Moritz, Robert L.

    2016-01-01

    Most shotgun proteomics data analysis workflows are based on the assumption that each fragment ion spectrum is explained by a single species of peptide ion isolated by the mass spectrometer; however, in reality mass spectrometers often isolate more than one peptide ion within the window of isolation that contributes to additional peptide fragment peaks in many spectra. We present a new tool called reSpect, implemented in the Trans-Proteomic Pipeline (TPP), that enables an iterative workflow whereby fragment ion peaks explained by a peptide ion identified in one round of sequence searching or spectral library search are attenuated based on the confidence of the identification, and then the altered spectrum is subjected to further rounds of searching. The reSpect tool is not implemented as a search engine, but rather as a post search engine processing step where only fragment ion intensities are altered. This enables the application of any search engine combination in the following iterations. Thus, reSpect is compatible with all other protein sequence database search engines as well as peptide spectral library search engines that are supported by the TPP. We show that while some datasets are highly amenable to chimeric spectrum identification and lead to additional peptide identification boosts of over 30% with as many as four different peptide ions identified per spectrum, datasets with narrow precursor ion selection only benefit from such processing at the level of a few percent. We demonstrate a technique that facilitates the determination of the degree to which a dataset would benefit from chimeric spectrum analysis. The reSpect tool is free and open source, provided within the TPP and available at the TPP website. PMID:26419769

  3. The SPECT imaging shows the accumulation of neural progenitor cells into internal organs after systemic administration in middle cerebral artery occlusion rats.

    PubMed

    Lappalainen, Riikka S; Narkilahti, Susanna; Huhtala, Tuulia; Liimatainen, Timo; Suuronen, Tiina; Närvänen, Ale; Suuronen, Riitta; Hovatta, Outi; Jolkkonen, Jukka

    2008-08-01

    The regenerative potential of stem cells from various sources has been under intense investigation in the experimental models of cerebral ischemia. To end up with a restorative therapeutic treatment, it is crucial to get the cell transplants to the site of injury. Here, we evaluated the feasibility of small animal SPECT/CT in assessing the definite accumulation of (111)In-oxine-labeled human embryonic stem (ES) cell-derived neural progenitors and rat hippocampal progenitors after intravenous or intra-arterial administration (femoral vein vs. common carotid artery) in middle cerebral artery occlusion (MCAO) and sham-operated rats. Cell detection was carried out immediately and 24h after the infusion using a SPECT/CT device. The results showed that after intravenous injections both cell types accumulated primarily into internal organs, instead of brain. In contrast, after intra-arterial injection, a weak signal was detected in the ischemic hemisphere. Additional studies showed that the detection sensitivity of SPECT/CT device was approximately 1000 (111)In-oxine-labeled cells and labeling did not affect the cell viability. In conclusion, a small animal SPECT is powerful technique to study the whole body biodistribution of cell-based therapies. Our data showed that intravenous administration is not an optimal route to deliver neural progenitor cell-containing transplants into the brain after MCAO in rats. PMID:18572314

  4. Combined SPECT and x-ray CT medical imaging system

    NASA Astrophysics Data System (ADS)

    Kalki, Kathrin; Brown, J. Keenan; Blankespoor, Stephen C.; Heanue, Joseph A.; Wu, Xiang; Cann, Christopher E.; Hasegawa, Bruce H.; Chin, Michael; Stillson, Carol A.; Dae, Michael W.; Carver, James M.

    1995-05-01

    We have designed and built a system for correlated x ray CT transmission and SPECT emission imaging with an array of photon counting detectors. The scanner operates in a third generation fan beam geometry by translating a 23 element high purity germanium detector across the fan to image phantoms and small animals. The x ray CT image is used to obtain an object specific, i.e., anatomically accurate, attenuation map for the reconstruction of the SPECT image. SPECT images are reconstructed with an MLEM code and the pixel values are scaled in physical units by determining a scaling factor from a uniform water phantom with homogeneous and known attenuation. Single myocardial slices of several pigs were imaged with a 99mTc sestamibi imaging agent which is taken up in proportion to regional myocardial blood flow. The results show that 99mTc uptake and regional myocardial blood flow, determined in vivo from reconstructed SPECT images, correlate with the measured in vitro data. Furthermore, the correlation is markedly improved by reconstructing the images with an object specific attenuation map obtained from the coregistered x ray CT image. We were also able to restore the 99mTc sestamibi uptake from the reconstructed images to an accuracy between 40% and 90% of the true in vitro value, depending on the selection of maximum or mean pixel values in the regions of interest.

  5. The role of SPECT in the evaluation of skeletal trauma.

    PubMed

    Murray, I P

    1993-02-01

    Single photon emission computed tomography (SPECT) has, in the last decade, established a critical role in routine diagnosis. Skeletal scintigraphy exemplifies the impact in improving detection of lesions by delineation of their site and size. The advantage of minimizing the superimposed radioactivity from overlying and underlying structures is typified by the readiness with which avascular necrosis of the femoral head can be identified by removal of the surrounding hyperaemia which masks the classical photopaenia. However, the ability to achieve an accurate image at a plane at a prescribed depth is most characteristically shown by the study of a vertebra, a bone of irregular contour and subject to a variety of pathological disorders at different sites within it. The various focal abnormalities resulting from these can be localized exactly, readily distinguishing, for example, those in the body from those in the natural arch. In particular, the alterations resulting from trauma, such as pars interarticularis stress fracture, are readily seen. Consequently SPECT has an indispensable role in the investigation and management of low back pain. However, the ability of SPECT to delineate abnormal accumulation has provided a new approach to the evaluation of knee pain, especially when acute such as that resulting from athletic injury, since the identification of the presence or absence of focal abnormalities can be critical to patient management. The frequency of these various disorders in which SPECT is so useful explains why the procedure has become such a routine high-volume examination is so many departments. PMID:8461235

  6. Hemimegalencephaly: Clinical, EEG, neuroimaging, and IMP-SPECT correlation

    SciTech Connect

    Konkol, R.J.; Maister, B.H.; Wells, R.G.; Sty, J.R. )

    1990-11-01

    Iofetamine-single photon emission computed tomography (IMP-SPECT) was performed on 2 girls (5 1/2 and 6 years of age) with histories of intractable seizures, developmental delay, and unilateral hemiparesis secondary to hemimegalencephaly. Electroencephalography (EEG) revealed frequent focal discharges in 1 patient, while a nearly continuous burst suppression pattern over the malformed hemisphere was recorded in the other. IMP-SPECT demonstrated a good correlation with neuroimaging studies. In spite of the different EEG patterns, which had been proposed to predict contrasting clinical outcomes, both IMP-SPECT scans disclosed a similar decrease in tracer uptake in the malformed hemisphere. These results are consistent with the pattern of decreased tracer uptake found in other interictal studies of focal seizures without cerebral malformations. In view of recent recommendations for hemispherectomy in these patients, we suggest that the IMP-SPECT scan be used to compliment EEG as a method to define the extent of abnormality which may be more relevant to long-term prognosis than EEG alone.

  7. Thallium-201 accumulation in cerebral candidiasis: Unexpected finding on SPECT

    SciTech Connect

    Tonami, N.; Matsuda, H.; Ooba, H.; Yokoyama, K.; Hisada, K.; Ikeda, K.; Yamashita, J. )

    1990-06-01

    The authors present an unexpected finding of Tl-201 uptake in the intracerebral lesions due to candidiasis. SPECT demonstrated the extent of the lesions and a high target-to-background ratio. The regions where abnormal Tl-201 accumulation was seen were nearly consistent with CT scans of those enhanced by a contrast agent. After treatment, most of the abnormal Tl-201 accumulation disappeared.

  8. The benefit of personalized hybrid SPECT/CT pulmonary imaging.

    PubMed

    Simanek, Milan; Koranda, Pavel

    2016-01-01

    Hybrid pulmonary imaging in the present day has seen a fusion of various uses of CT scans, including angiography (CTAG), diagnostic CT, low dose CT (LDCT), and perfusion or ventilation scintigraphy in tomographic or planar imaging. Determining the most effective individualized test for the complete diagnostics of patients with pulmonary symptoms for various groups of patients is a major issue. The aim of the present study was to assess the effectiveness of the implementation of hybrid imaging in current methods of nuclear medicine in differential diagnostics of pulmonary embolism (PE). 326 patients were examined for symptomatology of PE. Patients were initially examined with SPECT perfusion scintigraphy. SPECT finding without sub-segmental or segmental defects was considered unproven PE but the finding of more segments or sub-segments in various lung parts was considered nearly proven PE. In the case of unclear findings, LDCT was added and in the case of a higher suspicion of PE, a ventilation examination was applied. It was possible to determine 83% of patients with the occurrence or exclusion of PE only on the basis of the perfusion SPECT examination and an X-ray or LDCT. LDCT was determined with 26% of the patients. With 41% of them, the use of LDCT resulted in an alternative diagnosis, explaining perfusion abnormalities. The research proved that use of SPECT/LDCT for differential diagnosis of lung symptoms brings about improvement in the diagnosis of pulmonary embolism or the identification of other lung diseases when lung perfusion abnormalities are recorded. PMID:27648373

  9. The benefit of personalized hybrid SPECT/CT pulmonary imaging

    PubMed Central

    Simanek, Milan; Koranda, Pavel

    2016-01-01

    Hybrid pulmonary imaging in the present day has seen a fusion of various uses of CT scans, including angiography (CTAG), diagnostic CT, low dose CT (LDCT), and perfusion or ventilation scintigraphy in tomographic or planar imaging. Determining the most effective individualized test for the complete diagnostics of patients with pulmonary symptoms for various groups of patients is a major issue. The aim of the present study was to assess the effectiveness of the implementation of hybrid imaging in current methods of nuclear medicine in differential diagnostics of pulmonary embolism (PE). 326 patients were examined for symptomatology of PE. Patients were initially examined with SPECT perfusion scintigraphy. SPECT finding without sub-segmental or segmental defects was considered unproven PE but the finding of more segments or sub-segments in various lung parts was considered nearly proven PE. In the case of unclear findings, LDCT was added and in the case of a higher suspicion of PE, a ventilation examination was applied. It was possible to determine 83% of patients with the occurrence or exclusion of PE only on the basis of the perfusion SPECT examination and an X-ray or LDCT. LDCT was determined with 26% of the patients. With 41% of them, the use of LDCT resulted in an alternative diagnosis, explaining perfusion abnormalities. The research proved that use of SPECT/LDCT for differential diagnosis of lung symptoms brings about improvement in the diagnosis of pulmonary embolism or the identification of other lung diseases when lung perfusion abnormalities are recorded.

  10. The benefit of personalized hybrid SPECT/CT pulmonary imaging

    PubMed Central

    Simanek, Milan; Koranda, Pavel

    2016-01-01

    Hybrid pulmonary imaging in the present day has seen a fusion of various uses of CT scans, including angiography (CTAG), diagnostic CT, low dose CT (LDCT), and perfusion or ventilation scintigraphy in tomographic or planar imaging. Determining the most effective individualized test for the complete diagnostics of patients with pulmonary symptoms for various groups of patients is a major issue. The aim of the present study was to assess the effectiveness of the implementation of hybrid imaging in current methods of nuclear medicine in differential diagnostics of pulmonary embolism (PE). 326 patients were examined for symptomatology of PE. Patients were initially examined with SPECT perfusion scintigraphy. SPECT finding without sub-segmental or segmental defects was considered unproven PE but the finding of more segments or sub-segments in various lung parts was considered nearly proven PE. In the case of unclear findings, LDCT was added and in the case of a higher suspicion of PE, a ventilation examination was applied. It was possible to determine 83% of patients with the occurrence or exclusion of PE only on the basis of the perfusion SPECT examination and an X-ray or LDCT. LDCT was determined with 26% of the patients. With 41% of them, the use of LDCT resulted in an alternative diagnosis, explaining perfusion abnormalities. The research proved that use of SPECT/LDCT for differential diagnosis of lung symptoms brings about improvement in the diagnosis of pulmonary embolism or the identification of other lung diseases when lung perfusion abnormalities are recorded. PMID:27648373

  11. CALOR87: HETC87, MICAP, EGS4, and SPECT

    SciTech Connect

    Gabriel, T.A.; Alsmiller, F.S.; Alsmiller, R.G. Jr.; Bishop, B.L.; Hermann, O.W.; Johnson, J.O.

    1987-01-01

    A brief history of CALOR (HETC, EGS, MICAP, SPECT) is presented to indicate the evolution of this code system. Details concerning the current modifications and additions to the high-energy transport code, HETC, are also presented and new comparisons with experimental data are included to verify the new physics improvements. 27 refs., 5 figs.

  12. Miscellaneous cancers (lung, thyroid, renal cancer, myeloma, and neuroendocrine tumors): role of SPECT and PET in imaging bone metastases.

    PubMed

    Chua, Sue; Gnanasegaran, Gopinath; Cook, Gary J R

    2009-11-01

    In this review, we assess the current role of single-photon emission computed tomography (SPECT) and positron emission tomography (PET) in the imaging of skeletal metastatic disease from a miscellaneous group of malignancies, including lung, thyroid, and renal carcinomas; multiple myeloma; and neuroendocrine tumors, and consider how recent advances may enhance their effectiveness in this area. Bone scintigraphy using technetium-labeled diphosphonates has long been the mainstay of functional imaging of bony metastases, but is of limited value in myeloma and aggressive osteolytic metastases, and has the limitation of relatively poor specificity. SPECT, as a tomographic imaging technique, produces three-dimensional images of tracer distribution from multiplanar images. Its application to bone scintigrams greatly aids accurate anatomic localization and sensitivity in detection of foci of tracer uptake. SPECT can equally be applied to scintigrams using radiotracers, which are specific for particular groups of tumors, such as somatostatin analogs for neuroendocrine tumors. The advent of combined SPECT/computed tomography (CT) systems has further enhanced the accuracy of SPECT in all these malignancies. PET uses positron-emitting radiotracers and achieves a higher spatial resolution than single-photon imaging. Its high resolution and coverage of the entire body have made it a highly effective technique for the evaluation of skeletal metastatic disease, particularly when combined with CT. (18)F-fluorodeoxyglucose ((18)F-FDG)-PET/CT now forms part of routine staging for many carcinomas, such as non-small-cell lung carcinomas, and may obviate the need for routine staging scintigraphy in these patients. As uptake of the most common PET radiotracer, (18)F-FDG, is dependent on the increased cellular metabolism of most tumors, it may enable earlier detection of metastatic foci than bone scintigraphy, which relies on detecting an osteoblastic response. Another significant

  13. Collimator design for a multipinhole brain SPECT insert for MRI

    SciTech Connect

    Van Audenhaege, Karen; Van Holen, Roel; Vanhove, Christian; Vandenberghe, Stefaan

    2015-11-15

    Purpose: Brain single photon emission computed tomography (SPECT) imaging is an important clinical tool, with unique tracers for studying neurological diseases. Nowadays, most commercial SPECT systems are combined with x-ray computed tomography (CT) in so-called SPECT/CT systems to obtain an anatomical background for the functional information. However, while CT images have a high spatial resolution, they have a low soft-tissue contrast, which is an important disadvantage for brain imaging. Magnetic resonance imaging (MRI), on the other hand, has a very high soft-tissue contrast and does not involve extra ionizing radiation. Therefore, the authors designed a brain SPECT insert that can operate inside a clinical MRI. Methods: The authors designed and simulated a compact stationary multipinhole SPECT insert based on digital silicon photomultiplier detector modules, which have shown to be MR-compatible and have an excellent intrinsic resolution (0.5 mm) when combined with a monolithic 2 mm thick LYSO crystal. First, the authors optimized the different parameters of the SPECT system to maximize sensitivity for a given target resolution of 7.2 mm in the center of the field-of-view, given the spatial constraints of the MR system. Second, the authors performed noiseless simulations of two multipinhole configurations to evaluate sampling and reconstructed resolution. Finally, the authors performed Monte Carlo simulations and compared the SPECT insert with a clinical system with ultrahigh-resolution (UHR) fan beam collimators, based on contrast-to-noise ratio and a visual comparison of a Hoffman phantom with a 9 mm cold lesion. Results: The optimization resulted in a stationary multipinhole system with a collimator radius of 150.2 mm and a detector radius of 172.67 mm, which corresponds to four rings of 34 diSPM detector modules. This allows the authors to include eight rings of 24 pinholes, which results in a system volume sensitivity of 395 cps/MBq. Noiseless simulations

  14. Advanced reconstruction of attenuation maps using SPECT emission data only

    NASA Astrophysics Data System (ADS)

    Salomon, André; Goedicke, Andreas; Aach, Til

    2009-02-01

    Today, attenuation corrected SPECT, typically performed using CT or Gadolinium line source based transmission scans, is more and more becoming standard in many medical applications. Moreover, the information about the material density distribution provided by these scans is key for other artifact compensation approaches in advanced SPECT reconstruction. Major drawbacks of these approaches are the additional patient radiation and hardware/maintenance costs as well as the additional workflow effort, e.g. if the CT scans are not performed on a hybrid scanner. It has been investigated in the past, whether it is possible to recover this structural information solely from the SPECT scan data. However, the investigated methods often result in noticeable image artifacts due to cross-dependences between attenuation and activity distribution estimation. With the simultaneous reconstruction method presented in this paper, we aim to effectively prevent these typical cross-talk artifacts using a-priori known atlas information of a human body. At first, an initial 3D shape model is coarsely registered to the SPECT data using anatomical landmarks and each organ structure within the model is identified with its typical attenuation coefficient. During the iterative reconstruction based on a modified ML-EM scheme, the algorithm simultaneously adapts both, the local activity estimation and the 3D shape model in order to improve the overall consistency between measured and estimated sinogram data. By explicitly avoiding topology modifications resulting in a non-anatomical state, we ensure that the estimated attenuation map remains realistic. Several tests with simulated as well as real patient SPECT data were performed to test the proposed algorithm, which demonstrated reliable convergence behaviour in both cases. Comparing the achieved results with available reference data, an overall good agreement for both cold as well as hot activity regions could be observed (mean deviation: -5.98%).

  15. Partial volume correction in SPECT reconstruction with OSEM

    NASA Astrophysics Data System (ADS)

    Erlandsson, Kjell; Thomas, Ben; Dickson, John; Hutton, Brian F.

    2011-08-01

    SPECT images suffer from poor spatial resolution, which leads to partial volume effects due to cross-talk between different anatomical regions. By utilising high-resolution structural images (CT or MRI) it is possible to compensate for these effects. Traditional partial volume correction (PVC) methods suffer from various limitations, such as correcting a single region only, returning only regional mean values, or assuming a stationary point spread function (PSF). We recently presented a novel method in which PVC was combined with the reconstruction process in order to take into account the distance dependent PSF in SPECT, which was based on filtered backprojection (FBP) reconstruction. We now present a new method based on the iterative OSEM algorithm, which has advantageous noise properties compared to FBP. We have applied this method to a series of 10 brain SPECT studies performed on healthy volunteers using the DATSCAN tracer. T1-weighted MRI images were co-registered to the SPECT data and segmented into 33 anatomical regions. The SPECT data were reconstructed using OSEM, and PVC was applied in the projection domain at each iteration. The correction factors were calculated by forward projection of a piece-wise constant image, generated from the segmented MRI. Images were also reconstructed using FBP and standard OSEM with and without resolution recovery (RR) for comparison. The images were evaluated in terms of striatal contrast and regional variability (CoV). The mean striatal contrast obtained with OSEM, OSEM-RR and OSEM-PVC relative to FBP were 1.04, 1.42 and 1.53, respectively, and the mean striatal CoV values are 1.05, 1.53, 1.07. Both OSEM-RR and OSEM-PVC results in images with significantly higher contrast as compared to FBP or OSEM, but OSEM-PVC avoids the increased regional variability of OSEM-RR due to improved structural definition.

  16. Activity concentration measurements using a conjugate gradient (Siemens xSPECT) reconstruction algorithm in SPECT/CT.

    PubMed

    Armstrong, Ian S; Hoffmann, Sandra A

    2016-11-01

    The interest in quantitative single photon emission computer tomography (SPECT) shows potential in a number of clinical applications and now several vendors are providing software and hardware solutions to allow 'SUV-SPECT' to mirror metrics used in PET imaging. This brief technical report assesses the accuracy of activity concentration measurements using a new algorithm 'xSPECT' from Siemens Healthcare. SPECT/CT data were acquired from a uniform cylinder with 5, 10, 15 and 20 s/projection and NEMA image quality phantom with 25 s/projection. The NEMA phantom had hot spheres filled with an 8 : 1 activity concentration relative to the background compartment. Reconstructions were performed using parameters defined by manufacturer presets available with the algorithm. The accuracy of activity concentration measurements was assessed. A dose calibrator-camera cross-calibration factor (CCF) was derived from the uniform phantom data. In uniform phantom images, a positive bias was observed, ranging from ∼6% in the lower count images to ∼4% in the higher-count images. On the basis of the higher-count data, a CCF of 0.96 was derived. As expected, considerable negative bias was measured in the NEMA spheres using region mean values whereas positive bias was measured in the four largest NEMA spheres. Nonmonotonically increasing recovery curves for the hot spheres suggested the presence of Gibbs edge enhancement from resolution modelling. Sufficiently accurate activity concentration measurements can easily be measured on images reconstructed with the xSPECT algorithm without a CCF. However, the use of a CCF is likely to improve accuracy further. A manual conversion of voxel values into SUV should be possible, provided that the patient weight, injected activity and time between injection and imaging are all known accurately.

  17. Activity concentration measurements using a conjugate gradient (Siemens xSPECT) reconstruction algorithm in SPECT/CT.

    PubMed

    Armstrong, Ian S; Hoffmann, Sandra A

    2016-11-01

    The interest in quantitative single photon emission computer tomography (SPECT) shows potential in a number of clinical applications and now several vendors are providing software and hardware solutions to allow 'SUV-SPECT' to mirror metrics used in PET imaging. This brief technical report assesses the accuracy of activity concentration measurements using a new algorithm 'xSPECT' from Siemens Healthcare. SPECT/CT data were acquired from a uniform cylinder with 5, 10, 15 and 20 s/projection and NEMA image quality phantom with 25 s/projection. The NEMA phantom had hot spheres filled with an 8 : 1 activity concentration relative to the background compartment. Reconstructions were performed using parameters defined by manufacturer presets available with the algorithm. The accuracy of activity concentration measurements was assessed. A dose calibrator-camera cross-calibration factor (CCF) was derived from the uniform phantom data. In uniform phantom images, a positive bias was observed, ranging from ∼6% in the lower count images to ∼4% in the higher-count images. On the basis of the higher-count data, a CCF of 0.96 was derived. As expected, considerable negative bias was measured in the NEMA spheres using region mean values whereas positive bias was measured in the four largest NEMA spheres. Nonmonotonically increasing recovery curves for the hot spheres suggested the presence of Gibbs edge enhancement from resolution modelling. Sufficiently accurate activity concentration measurements can easily be measured on images reconstructed with the xSPECT algorithm without a CCF. However, the use of a CCF is likely to improve accuracy further. A manual conversion of voxel values into SUV should be possible, provided that the patient weight, injected activity and time between injection and imaging are all known accurately. PMID:27501436

  18. Unlocking the Secrets of the Brain, Part II: A Continuing Look at Techniques for Exploring the Brain.

    ERIC Educational Resources Information Center

    Powledge, Tabitha M.

    1997-01-01

    Describes techniques for delving into the brain including positron emission tomography (PET), single photon emission computed tomography (SPECT), electroencephalogram (EEG), magnetoencephalography (MEG), transcranial magnetic stimulation (TMS), and low-tech indirect studies. (JRH)

  19. Factors affecting the sensitivity and detection limits of MRI, CT, and SPECT for multimodal diagnostic and therapeutic agents.

    PubMed

    Seevinck, Peter R; Seppenwoolde, Jan-Henry; de Wit, Tim C; Nijsen, Johannes F W; Beekman, Freek J; van Het Schip, Alfred D; Bakker, Chris J G

    2007-05-01

    Noninvasive imaging techniques like magnetic resonance imaging (MRI), computed tomography (CT) and single photon emission computed tomography (SPECT) play an increasingly important role in the diagnostic workup and treatment of cancerous disease. In this context, a distinct trend can be observed towards the development of contrast agents and radiopharmaceuticals that open up perspectives on a multimodality imaging approach, involving all three aforementioned techniques. To promote insight into the potentialities of such an approach, we prepared an overview of the strengths and limitations of the various imaging techniques, in particular with regard to their capability to quantify the spatial distribution of a multimodal diagnostic agent. To accomplish this task, we used a two-step approach. In the first step, we examined the situation for a particular therapeutic anti-cancer agent with multimodal imaging opportunities, viz. holmium-loaded microspheres (HoMS). Physical phantom experiments were performed to enable a comparative evaluation of the three modalities assuming the use of standard equipment, standard clinical scan protocols, and signal-known-exactly conditions. These phantom data were then analyzed so as to obtain first order estimates of the sensitivity and detection limits of MRI, CT and SPECT for HoMS. In the second step, the results for HoMS were taken as a starting point for a discussion of the factors affecting the sensitivity and detection limits of MRI, CT and SPECT for multimodal agents in general. In this, emphasis was put on the factors that must be taken into account when extrapolating the findings for HoMS to other diagnostic tasks, other contrast agents, other experimental conditions, and other scan protocols.

  20. [Rest gated-SPECT myocardial perfusion post (99m)Tc-MIBI injection in a patient with acute chest pain and with no medical history of ischemic heart disease].

    PubMed

    Negre-Busó, M; Muntaner-Muñoz, L; Rubió-Rodríguez, A; Marin-Buriticá, A; Ferran-Sureda, N; Bassaganyas-Vilarrasa, J

    2015-01-01

    Gated-SPECT myocardial perfusion imaging is a widely used technique indicated for assessment of patients with no clear diagnosis of ischemic heart disease. Early rest gated-SPECT myocardial perfusion study in patients with acute chest pain has high sensitivity and high negative predictive value for ruling out coronary disease. We report a case of a patient admitted for the study of her chest pain. She underwent a myocardial perfusion stress-rest whose interpretation could have been equivocal due to the clinical status of the patient during the injection of the radiotracer. PMID:25759109

  1. Diagnosis of myocardial involvement in patients with systemic myopathies with 15-(p-[I-123]iodophenyl) pentadecanoic acid (IPPA) SPECT

    SciTech Connect

    Kropp, J.; Briele, B.; Smekal, A.V.; Hotze, A.L.; Biersack, H.J.; Koehler, U.; Zierz, St.; Knapp, F.F.

    1992-03-01

    Involvement of the myocardium in non-infectious myopathies presents in most cases as systolic dysfunction or a disturbed cardiac rhythm. We are interested in exploring how often cardiac involvement can be evaluated with various diagnostic techniques in patients with proven myopathy. We investigated 41 patients with myopathies of various etiology, including mitochondrial and congenital myopathies, Curshmann-Steinert disease, muscular dystrophy, and others. Myopathy was proven by muscular biopsy usually from the bicep. Fatty acid imaging was performed with 15-(p-[I-123]iodophenyl)pentadecanoic acid (IP-PA) and sequential SPECT-scintigraphy with a 180 deg. rotation starting at the 45 deg. RAO position. 190 MBq were injected at the maximal stage of a submaximal exercise. Filtered backprojection and reorientation of the slices were achieved by standard techniques. The quantitative comparison of the oblique slices (bulls-eye technique) of the SPECT-studies revealed turnover-rates as a qualitative measure of {beta}-oxidation. Serum levels of lactate (L), pyruvate (P), glucose (G) and triglycerides (TG) were measured at rest and stress. Ventricular function was investigated by radionuclide ventriculography (MUGA) at rest and under stress with Tc-99m labeled red blood cells. In addition, ECG, 24 hour-ECG, and echocardiography were also performed with standard techniques.

  2. Diagnosis of myocardial involvement in patients with systemic myopathies with 15-(p-(I-123)iodophenyl) pentadecanoic acid (IPPA) SPECT

    SciTech Connect

    Kropp, J.; Briele, B.; Smekal, A.V.; Hotze, A.L.; Biersack, H.J.; Koehler, U.; Zierz, St. ); Knapp, F.F. )

    1992-01-01

    Involvement of the myocardium in non-infectious myopathies presents in most cases as systolic dysfunction or a disturbed cardiac rhythm. We are interested in exploring how often cardiac involvement can be evaluated with various diagnostic techniques in patients with proven myopathy. We investigated 41 patients with myopathies of various etiology, including mitochondrial and congenital myopathies, Curshmann-Steinert disease, muscular dystrophy, and others. Myopathy was proven by muscular biopsy usually from the bicep. Fatty acid imaging was performed with 15-(p-(I-123)iodophenyl)pentadecanoic acid (IP-PA) and sequential SPECT-scintigraphy with a 180 deg. rotation starting at the 45 deg. RAO position. 190 MBq were injected at the maximal stage of a submaximal exercise. Filtered backprojection and reorientation of the slices were achieved by standard techniques. The quantitative comparison of the oblique slices (bulls-eye technique) of the SPECT-studies revealed turnover-rates as a qualitative measure of {beta}-oxidation. Serum levels of lactate (L), pyruvate (P), glucose (G) and triglycerides (TG) were measured at rest and stress. Ventricular function was investigated by radionuclide ventriculography (MUGA) at rest and under stress with Tc-99m labeled red blood cells. In addition, ECG, 24 hour-ECG, and echocardiography were also performed with standard techniques.

  3. Brain SPECT Imaging in Complex Psychiatric Cases: An Evidence-Based, Underutilized Tool

    PubMed Central

    Amen, Daniel G; Trujillo, Manuel; Newberg, Andrew; Willeumier, Kristen; Tarzwell, Robert; Wu, Joseph C; Chaitin, Barry

    2011-01-01

    Over the past 20 years brain Single Photon Emission Computed Tomography (SPECT) imaging has developed a substantial, evidence-based foundation and is now recommended by professional societies for numerous indications relevant to psychiatric practice. Unfortunately, SPECT in clinical practice is utilized by only a handful of clinicians. This article presents a rationale for a more widespread use of SPECT in clinical practice for complex cases, and includes seven clinical applications where it may help optimize patient care. PMID:21863144

  4. 99mTc-MDP SPECT/CT for assessment of condylar hyperplasia.

    PubMed

    Derlin, Thorsten; Busch, Jasmin D; Habermann, Christian R

    2013-01-01

    We report a case of condylar hyperplasia diagnosed with 99mTc-MDP SPECT/CT. A 21-year-old woman with facial asymmetry was referred for assessment of condylar growth activity. SPECT/CT confirmed condylar hyperactivity, and simultaneous low-dose CT contributed to the diagnosis of hemimandibular hyperplasia. SPECT/CT may become a valuable tool for the diagnosis and comprehensive assessment of condylar hyperplasia, providing both functional and morphological information. PMID:23242067

  5. Design and simulation of a high-resolution stationary SPECT system for small animals

    NASA Astrophysics Data System (ADS)

    Beekman, Freek J.; Vastenhouw, Brendan

    2004-10-01

    Exciting new SPECT systems can be created by combining pinhole imaging with compact high-resolution gamma cameras. These new systems are able to solve the problem of the limited sensitivity-resolution trade-off that hampers contemporary small animal SPECT. The design presented here (U-SPECT-III) uses a set of detectors placed in a polygonal configuration and a cylindrical collimator that contains 135 pinholes arranged in nine rings. Each ring contains 15 gold pinhole apertures that focus on the centre of the cylinder. A non-overlapping projection is acquired via each pinhole. Consequently, when a mouse brain is placed in the central field-of-view, each voxel in the cerebrum can be observed via 130 to 135 different pinholes simultaneously. A method for high-resolution scintillation detection is described that eliminates the depth-of-interaction problem encountered with pinhole cameras, and is expected to provide intrinsic detector resolutions better than 150 µm. By means of simulations U-SPECT-III is compared to a simulated dual pinhole SPECT (DP-SPECT) system with a pixelated array consisting of 2.0 × 2.0 mm NaI crystals. Analytic calculations indicate that the proposed U-SPECT-III system yields an almost four times higher linear and about sixty times higher volumetric system resolution than DP-SPECT, when the systems are compared at matching system sensitivity. In addition, it should be possible to achieve a 15 up to 30 times higher sensitivity with U-SPECT-III when the systems are compared at equal resolution. Simulated images of a digital mouse-brain phantom show much more detail with U-SPECT-III than with DP-SPECT. In a resolution phantom, 0.3 mm diameter cold rods are clearly visible with U-SPECT-III, whereas with DP-SPECT the smallest visible rods are about 0.6-0.8 mm. Furthermore, with U-SPECT-III, the image deformations outside the central plane of reconstruction that hamper conventional pinhole SPECT are strongly suppressed. Simulation results indicate

  6. Potential value of serial cerebral SPECT scanning in the evaluation of psychiatric illness

    SciTech Connect

    Notardonato, H.; Gonzalez-Avilez, A.; Van Heertum, R.L.; O'Connell, R.A.; Yudd, A.P.

    1989-05-01

    Cerebral SPECT imaging has the potential to make an important contribution to clinical psychiatry. Cerebral SPECT scanning, stimulated by the work with PET, is readily available and much less expensive than PET. This paper reports a case demonstrating the potential value of cerebral SPECT scanning with I-123 IMP, specifically in the serial evaluation of a schizophrenic patient with auditory hallucinations. The initial scan revealed focal areas of increased uptake in the caudate nuclei of the basal ganglia, and in the right temporal lobe. After pharmacological treatment with clinical improvement, the follow-up SPECT scan demonstrated significant improvement in the distribution of the radiopharmaceutical.

  7. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision.

    PubMed

    Verberne, Hein J; Acampa, Wanda; Anagnostopoulos, Constantinos; Ballinger, Jim; Bengel, Frank; De Bondt, Pieter; Buechel, Ronny R; Cuocolo, Alberto; van Eck-Smit, Berthe L F; Flotats, Albert; Hacker, Marcus; Hindorf, Cecilia; Kaufmann, Philip A; Lindner, Oliver; Ljungberg, Michael; Lonsdale, Markus; Manrique, Alain; Minarik, David; Scholte, Arthur J H A; Slart, Riemer H J A; Trägårdh, Elin; de Wit, Tim C; Hesse, Birger

    2015-11-01

    Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated 2015 procedural guidelines are highlighted, focusing on the important changes related to new instrumentation with improved image information and the possibility to reduce radiation exposure, which is further discussed in relation to the recent developments of new International Commission on Radiological Protection (ICRP) models. Introduction of the selective coronary vasodilator regadenoson and the use of coronary CT-contrast agents for hybrid imaging with SPECT/CT angiography are other important areas for nuclear cardiology that were not included in the previous guidelines. A large number of minor changes have been described in more detail in the fully revised version available at the EANM home page: http://eanm.org/publications/guidelines/2015_07_EANM_FINAL_myocardial_perfusion_guideline.pdf .

  8. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision.

    PubMed

    Verberne, Hein J; Acampa, Wanda; Anagnostopoulos, Constantinos; Ballinger, Jim; Bengel, Frank; De Bondt, Pieter; Buechel, Ronny R; Cuocolo, Alberto; van Eck-Smit, Berthe L F; Flotats, Albert; Hacker, Marcus; Hindorf, Cecilia; Kaufmann, Philip A; Lindner, Oliver; Ljungberg, Michael; Lonsdale, Markus; Manrique, Alain; Minarik, David; Scholte, Arthur J H A; Slart, Riemer H J A; Trägårdh, Elin; de Wit, Tim C; Hesse, Birger

    2015-11-01

    Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated 2015 procedural guidelines are highlighted, focusing on the important changes related to new instrumentation with improved image information and the possibility to reduce radiation exposure, which is further discussed in relation to the recent developments of new International Commission on Radiological Protection (ICRP) models. Introduction of the selective coronary vasodilator regadenoson and the use of coronary CT-contrast agents for hybrid imaging with SPECT/CT angiography are other important areas for nuclear cardiology that were not included in the previous guidelines. A large number of minor changes have been described in more detail in the fully revised version available at the EANM home page: http://eanm.org/publications/guidelines/2015_07_EANM_FINAL_myocardial_perfusion_guideline.pdf . PMID:26290421

  9. Anamorphic preclinical SPECT imaging with high-resolution silicon double-sided strip detectors

    NASA Astrophysics Data System (ADS)

    Durko, Heather L.

    Preclinical single-photon emission computed tomography (SPECT) is an essential tool for studying progression, response to treatment, and physiological changes in small animal models of human disease. The wide range of imaging applications is often limited by the static design of many preclinical SPECT systems. We have developed a prototype imaging system that replaces the standard static pinhole aperture with two sets of movable, keel-edged copper-tungsten blades configured as crossed (skewed) slits. These apertures can be positioned independently between the object and detector, producing an anamorphic image in which the axial and transaxial magnications are not constrained to be equal. We incorporated a 60 mm x 60 mm, millimeter-thick megapixel silicon double-sided strip detector that permits ultrahigh-resolution imaging. While the stopping power of silicon is low for many common clinical radioisotopes, its performance is sufficient in the range of 20-60 keV to allow practical imaging experiments. The low-energy emissions of 125I fall within this energy window, and the 60-day half life provides an advantage for longitudinal studies. The flexible nature of this system allows the future application of adaptive imaging techniques. We have demonstrated ˜225-mum axial and ˜175-mum transaxial resolution across a 2.65 cm3 cylindrical field of view, as well as the capability for simultaneous multi-isotope acquisitions. We describe the key advancements that have made this system operational, including bringing up a new detector readout ASIC, development of detector control software and data-processing algorithms, and characterization of operating characteristics. We describe design and fabrication of the adjustable slit aperture platform, as well as the development of an accurate imaging forward model and its application in a novel geometric calibration technique and a GPU-based ultrahigh-resolution reconstruction code.

  10. Efficacy of (99m)Tc-EDDA/HYNIC-TOC SPECT/CT scintigraphy in Graves' ophthalmopathy.

    PubMed

    Zhao, Rong; Wang, Jiang; Deng, Jinglan; Yang, Weidong; Wang, Jing

    2012-01-01

    The aim of this study was to investigate the predictive role of the orbital somatostatin receptor scintigraphy with (99m)Tc-EDDA/HYNIC-TOC ((99m)Tc-TOC) to detect clinical stage of Graves' ophthalmopathy and the response to corticosteroid therapy. The subjects of the experiment were 46 patients with Graves' ophthalmopathy (GO) and four volunteers without eye disease or GO as the normal group (NG). Single photon emission computed tomography (SPECT), computed tomography (CT) and the left and right lateral position planar imaging of the heads of the all subjects were obtained 4 h after the intravenous injection of 555 MBq of (99m)Tc-TOC. The (99m)Tc-TOC SPECT/CT was repeated 3 months later. 35 (35/46) patients were received corticosteroid therapy (prednisolone, 10 mg po tid ) for 3 months, however, the other 11 patients as control groups did not receive any treatment. The treatment effect was evaluated both by the orbital (99m)Tc-TOC uptake and NOSPECS. A significant decrease in the O/OC ratio was observed in 22 GO patients between pre- and post-treatment (1.64 ± 0.13 vs. 1.21 ± 0.09, P < 0.05). There were neither significant difference of the O/OC ratio in 13 GO patients between pre- and post-treatment periods, nor significant difference in the 9 (9/11) patients before and after three months. Orbital (99m)Tc-TOC scintigraphy is a feasible technique to estimate the Graves' ophthalmopathy activity and predict the response to subsequent corticosteroid therapy in GO patients. The technique could be a useful tool for physicians not familiar with CAS determination.

  11. Recent advances in cardiac SPECT instrumentation and system design.

    PubMed

    Smith, Mark F

    2013-08-01

    Recent advances in clinical cardiac SPECT instrumentation are reviewed from a systems perspective. New hardware technologies include pixelated scintillator and semiconductor detector elements; photodetectors such as position-sensitive photomultiplier tubes (PSPMT), avalanche photodiodes (APD) and silicon photomultipliers (SiPM); and novel cardiac collimation methods. There are new approaches for positioning detectors and controlling their motion during cardiac imaging. Software technology advances include iterative image reconstruction with modeling of Poisson statistics and depth-dependent collimator response. These new technologies enable faster acquisitions, the lowering of administered activity and radiation dose, and improved image resolution. Higher sensitivity collimators are a significant factor enabling faster acquisitions. Several clinical systems incorporating new technologies are discussed and different system designs can achieve similar performance. With detector elements such as APDs, SiPMs and semiconductors that are insensitive to magnetic fields, the potential for cardiac SPECT imagers that are MRI compatible opens up new frontiers in clinical cardiac research and patient care. PMID:23832650

  12. High-order total variation minimization for interior SPECT

    PubMed Central

    Yang, Jiansheng; Yu, Hengyong; Jiang, Ming; Wang, Ge

    2011-01-01

    Recently, we developed an approach for solving the computed tomography (CT) interior problem based on the high-order TV (HOT) minimization, assuming that a region-of-interest (ROI) is piecewise polynomial. In this paper, we generalize this finding from the CT field to the single-photon emission computed tomography (SPECT) field, and prove that if an ROI is piecewise polynomial, then the ROI can be uniquely reconstructed from the SPECT projection data associated with the ROI through the HOT minimization. Also, we propose a new formulation of HOT, which has an explicit formula for any n-order piecewise polynomial function, while the original formulation has no explicit formula for n ≥ 2. Finally, we verify our theoretical results in numerical simulation, and discuss relevant issues. PMID:22215932

  13. Accuracy of quantitative reconstructions in SPECT/CT imaging

    NASA Astrophysics Data System (ADS)

    Shcherbinin, S.; Celler, A.; Belhocine, T.; van der Werf, R.; Driedger, A.

    2008-09-01

    The goal of this study was to determine the quantitative accuracy of our OSEM-APDI reconstruction method based on SPECT/CT imaging for Tc-99m, In-111, I-123, and I-131 isotopes. Phantom studies were performed on a SPECT/low-dose multislice CT system (Infinia-Hawkeye-4 slice, GE Healthcare) using clinical acquisition protocols. Two radioactive sources were centrally and peripherally placed inside an anthropometric Thorax phantom filled with non-radioactive water. Corrections for attenuation, scatter, collimator blurring and collimator septal penetration were applied and their contribution to the overall accuracy of the reconstruction was evaluated. Reconstruction with the most comprehensive set of corrections resulted in activity estimation with error levels of 3-5% for all the isotopes.

  14. SPECT study of regional cerebral blood flow in Alzheimer disease

    SciTech Connect

    Bonte, F.J.; Ross, E.D.; Chehabi, H.H.; Devous, M.D. Sr.

    1986-07-01

    A common cause of dementia in late midlife and old age is Alzheimer disease (AD), which affects more than one in 20 individuals over the age of 65. Past studies of regional cerebral blood flow (rCBF) in patients with AD here suggested blood flow abnormalities, but findings have differed. We have studied 37 patients diagnosed as having AD with inhalation and washout of /sup 133/Xe and single-photon emission computed tomography (SPECT), obtaining evidence of abnormal rCBF patterns in 19. Flow reductions were most common in the temporoparietal regions and were occasionally found in the frontal areas. Investigators using positron-emission tomography (PET) have identified similar findings with respect to rCBF and regional oxygen, glucose, and protein metabolism. The SPECT determination of rCBF, which gives information similar to that provided by PET, may assume importance in the diagnosis of AD and in the differential diagnosis of the dementias.

  15. Bone Scintigraphy SPECT/CT Evaluation of Mandibular Condylar Hyperplasia.

    PubMed

    Yang, Zhiyun; Reed, Tameron; Longino, Becky H

    2016-03-01

    Mandibular condylar hyperplasia (CH) is a complex developmental deformity resulting in asymmetries of the hyperplastic condyle. Bone scan SPECT is a sensitive and accurate method of detecting the growth activity of this disorder. This method can be used to quantitate the radionuclide uptake differences between the left and right condyles. Uptake differences of 10% or more between the left and right condyles, with increased uptake ipsilateral to the CH, are considered to be evidence of active growing CH. Quantitative assessment of CH is important to select an appropriate treatment course. Degenerative arthropathies of the temporomandibular joints may result in altered uptake, but this is mostly associated with the side contralateral to the CH. The CT portion of SPECT/CT is useful to assess the condylar dimensions and underlying bony changes. PMID:26111714

  16. Dual-headed SPECT for awake animal brain imaging

    SciTech Connect

    S. Lee, B. Kross, D. Weisenberger, J. McKisson, J.S. Goddard, J.S. Baba, M.S. Smith

    2012-02-01

    Motion-corrected awake animal imaging is needed for normal-state investigations of models of neurological disease and brain activity. The awake animal brain SPECT/CT system, AwakeSPECT at Johns Hopkins University has in the past used a single gamma camera for imaging. Enhancements have been made by adding a pinhole collimator to the second gamma camera at the opposite side which has been previously equipped parallel hole collimator. Geometry calibration was performed using a custom built quality control phantom containing three Co-57 point sources and applied to the tomographic reconstruction code. Hot-rod phantom scans with Tc-99m were performed to test sensitivity and resolution improvements. The reconstruction results show significant resolution and sensitivity improvements.

  17. Dual-headed SPECT for awake animal brain imaging

    SciTech Connect

    Lee, Seung Joon; Weisenberger, A G; McKisson, J; Goddard Jr, James Samuel; Baba, Justin S; Smith, M F

    2011-01-01

    Abstract- Motion-corrected awake animal imaging is needed for normal-state investigations of models of neurological disease and brain activity. The awake animal brain SPECT/CT system, AwakeSPECT at Johns Hopkins University has in the past used a single gamma camera for imaging. Enhancements have been made by adding a pinhole collimator to the second gamma camera at the opposite side which has been previously equipped parallel hole collimator. Geometry calibration was performed using a custom built quality control phantom containing three Co-57 point sources and applied to the tomographic reconstruction code. Hot-rod phantom scans with Tc-99m were performed to test sensitivity and resolution improvements. The reconstruction results show significant resolution and sensitivity improvements.

  18. Vertebrobasilar insufficiency revealed by xenon-133 inhalation SPECT

    SciTech Connect

    Delecluse, F.; Voordecker, P.; Raftopoulos, C.

    1989-07-01

    A study of cerebral and cerebellar blood flow reactivity to acetazolamide by xenon-133-inhalation single photon emission computed tomography (/sup 133/Xe SPECT) was carried out in a patient with bouts of transient basilar ischemia, whose neurological examination, computed tomographic scan, and auditory evoked potentials were normal. Though the patient was symptom-free at the time of the study, /sup 133/Xe SPECT demonstrated vertebrobasilar insufficiency by showing an impaired vasodilatory response in both the occipital lobes and the right cerebellar hemisphere. Three weeks later, the patient suffered an extensive stroke in these same areas. We therefore suggest that this method could be of great value in the assessment of vertebrobasilar insufficiency.

  19. Infective endocarditis detection through SPECT/CT images digital processing

    NASA Astrophysics Data System (ADS)

    Moreno, Albino; Valdés, Raquel; Jiménez, Luis; Vallejo, Enrique; Hernández, Salvador; Soto, Gabriel

    2014-03-01

    Infective endocarditis (IE) is a difficult-to-diagnose pathology, since its manifestation in patients is highly variable. In this work, it was proposed a semiautomatic algorithm based on SPECT images digital processing for the detection of IE using a CT images volume as a spatial reference. The heart/lung rate was calculated using the SPECT images information. There were no statistically significant differences between the heart/lung rates values of a group of patients diagnosed with IE (2.62+/-0.47) and a group of healthy or control subjects (2.84+/-0.68). However, it is necessary to increase the study sample of both the individuals diagnosed with IE and the control group subjects, as well as to improve the images quality.

  20. Os trigonum syndrome on bone SPECT/CT.

    PubMed

    Huang, Jianmin; Servaes, Sabah; Zhuang, Hongming

    2014-08-01

    A 16-year-old female athlete presented with increased pain in the distal left lower extremity. A possible stress fracture or shin splint of the left tibia was first considered. A 3-phase bone scintigraphy showed a very small focus of increased activity in the posterior left foot. A diagnosis of os trigonum syndrome was made after SPECT/CT images pinpointed the activity at the left os trigonum.

  1. [Usefulness of attenuation correction with transmission source in myocardial SPECT].

    PubMed

    Murakawa, Keizo; Katafuchi, Tetsuro; Nishimura, Yoshihiro; Enomoto, Naoyuki; Sago, Masayoshi; Oka, Hisashi

    2006-01-20

    Attenuation correction in SPECT has been used for uniformly absorptive objects like the head. On the other hand, it has seldom been applied to nonuniform absorptive objects like the heart and surrounding lungs because of the difficulty and inaccuracy of data processing. However, since attenuation correction using a transmission source recently became practical, we were able to apply this method to a nonuniform absorptive object. Therefore, we evaluated the usefulness of this attenuation correction system with a transmission source in myocardial SPECT. The dose linearity, defect/normal ratio using a myocardial phantom, and myocardial count distribution in clinical cases was examined with and without the attenuation correction system. We found that all data processed with attenuation correction were better than those without attenuation correction. For example, in myocardial count distribution, while there was a difference between men and women without attenuation correction, which was considered to be caused by differences in body shape, after processing with attenuation correction, myocardial count distribution was almost the same in all cases. In conclusion, these results suggested that attenuation correction with a transmission source was useful in myocardial SPECT.

  2. Dynamic heart-in-thorax phantom for functional SPECT

    SciTech Connect

    Celler, A.; Lyster, D.; Farncombe, T.

    1996-12-31

    We have designed and built a dynamic heart-in-thorax phantom to be used as a primary tool during the experimental verification of the performance of the quantitative dynamic functional imaging method we are developing for standard rotating single photon emission computed tomography (SPECT) cameras. The phantom consists of two independent parts (i) a dynamic heart model with the possibility of mounting {open_quotes}defects{close_quotes} inside it and (ii) a non-uniform thorax model with lungs and spinal cord, and uses the fact that the washout of a tracer by dilution is governed by a linear first order equation, the same type of equation as is used to model time-activity distribution in myocardial viability studies. Tests of the dynamic performance of the phantom in planar scanning mode have confirmed the validity of these assumptions. Also the preliminary results obtained in SPECT mode show that the values of characteristic times could be experimentally determined and that these values agreed well with the values preset on the phantom. We consider that the phantom is ready for extensive use in studies into development of the dynamic SPECT method.

  3. Evaluating low pass filters on SPECT reconstructed cardiac orientation estimation

    NASA Astrophysics Data System (ADS)

    Dwivedi, Shekhar

    2009-02-01

    Low pass filters can affect the quality of clinical SPECT images by smoothing. Appropriate filter and parameter selection leads to optimum smoothing that leads to a better quantification followed by correct diagnosis and accurate interpretation by the physician. This study aims at evaluating the low pass filters on SPECT reconstruction algorithms. Criteria for evaluating the filters are estimating the SPECT reconstructed cardiac azimuth and elevation angle. Low pass filters studied are butterworth, gaussian, hamming, hanning and parzen. Experiments are conducted using three reconstruction algorithms, FBP (filtered back projection), MLEM (maximum likelihood expectation maximization) and OSEM (ordered subsets expectation maximization), on four gated cardiac patient projections (two patients with stress and rest projections). Each filter is applied with varying cutoff and order for each reconstruction algorithm (only butterworth used for MLEM and OSEM). The azimuth and elevation angles are calculated from the reconstructed volume and the variation observed in the angles with varying filter parameters is reported. Our results demonstrate that behavior of hamming, hanning and parzen filter (used with FBP) with varying cutoff is similar for all the datasets. Butterworth filter (cutoff > 0.4) behaves in a similar fashion for all the datasets using all the algorithms whereas with OSEM for a cutoff < 0.4, it fails to generate cardiac orientation due to oversmoothing, and gives an unstable response with FBP and MLEM. This study on evaluating effect of low pass filter cutoff and order on cardiac orientation using three different reconstruction algorithms provides an interesting insight into optimal selection of filter parameters.

  4. Adaptive Autoregressive Model for Reduction of Noise in SPECT.

    PubMed

    Takalo, Reijo; Hytti, Heli; Ihalainen, Heimo; Sohlberg, Antti

    2015-01-01

    This paper presents improved autoregressive modelling (AR) to reduce noise in SPECT images. An AR filter was applied to prefilter projection images and postfilter ordered subset expectation maximisation (OSEM) reconstruction images (AR-OSEM-AR method). The performance of this method was compared with filtered back projection (FBP) preceded by Butterworth filtering (BW-FBP method) and the OSEM reconstruction method followed by Butterworth filtering (OSEM-BW method). A mathematical cylinder phantom was used for the study. It consisted of hot and cold objects. The tests were performed using three simulated SPECT datasets. Image quality was assessed by means of the percentage contrast resolution (CR%) and the full width at half maximum (FWHM) of the line spread functions of the cylinders. The BW-FBP method showed the highest CR% values and the AR-OSEM-AR method gave the lowest CR% values for cold stacks. In the analysis of hot stacks, the BW-FBP method had higher CR% values than the OSEM-BW method. The BW-FBP method exhibited the lowest FWHM values for cold stacks and the AR-OSEM-AR method for hot stacks. In conclusion, the AR-OSEM-AR method is a feasible way to remove noise from SPECT images. It has good spatial resolution for hot objects.

  5. Compact CT/SPECT Small-Animal Imaging System

    PubMed Central

    Kastis, George A.; Furenlid, Lars R.; Wilson, Donald W.; Peterson, Todd E.; Barber, H. Bradford; Barrett, Harrison H.

    2015-01-01

    We have developed a dual-modality CT/SPECT imaging system for small-animal imaging applications. The X-ray system comprises a commercially available micro-focus X-ray tube and a CCD-based X-ray camera. X-ray transmission measurements are performed based on cone-beam geometry. Individual projections are acquired by rotating the animal about a vertical axis in front of the CCD detector. A high-resolution CT image is obtained after reconstruction using an ordered subsets-expectation maximization (OS-EM) reconstruction algorithm. The SPECT system utilizes a compact semiconductor camera module previously developed in our group. The module is mounted perpendicular to the X-ray tube/CCD combination. It consists of a 64×64 pixellated CdZnTe detector and a parallel-hole tungsten collimator. The field of view is 1 square inch. Planar projections for SPECT reconstruction are obtained by rotating the animal in front of the detector. Gamma-ray and X-ray images are presented of phantoms and mice. Procedures for merging the anatomical and functional images are discussed. PMID:26538684

  6. SPECT imaging as a tool to prevent proliferation of nuclear weapons

    NASA Astrophysics Data System (ADS)

    Lundqvist, Tobias; Jacobsson Svärd, Staffan; Håkansson, Ane

    2007-10-01

    International efforts are taken to avoid the proliferation of material and technologies that may lead to the development of nuclear weapons. These activities are called safeguards and involve inspections of spent nuclear fuel at nuclear power plants and storage facilities. At these inspections, various measuring techniques are employed for verifying the presence and identity of spent nuclear fuel assemblies. However, a fuel assembly contains about 100-300 fuel rods and techniques are also required for verifying that no individual fuel rods have been removed from the assembly. For this purpose, a non-destructive tomographic measurement technique for spent-fuel assemblies is being developed at Uppsala University, based on single photon emission computed tomography (SPECT). The technique utilizes the γ-ray emission from spent fuel. The first step of the methodology is the recording of the γ-ray flux distribution in a large number of positions around the fuel assembly, using γ-ray detectors attached to a collimator system. In the following step, a cross-sectional image of the source distribution in the fuel assembly is reconstructed. Because the fuel rods are highly activated during reactor operation, and because they are stored in water with practically no radioactive content, they appear very clearly in this type of image. The technique has earlier been used for determining the power distribution in fuel assemblies [S. Jacobsson Svärd, A. Håkansson, et al., Nucl. Technol. 151(1) (2005) 70. [1

  7. Analytical, experimental, and Monte Carlo system response matrix for pinhole SPECT reconstruction

    SciTech Connect

    Aguiar, Pablo; Pino, Francisco; Silva-Rodríguez, Jesús; Pavía, Javier; Ros, Doménec; Ruibal, Álvaro; and others

    2014-03-15

    Purpose: To assess the performance of two approaches to the system response matrix (SRM) calculation in pinhole single photon emission computed tomography (SPECT) reconstruction. Methods: Evaluation was performed using experimental data from a low magnification pinhole SPECT system that consisted of a rotating flat detector with a monolithic scintillator crystal. The SRM was computed following two approaches, which were based on Monte Carlo simulations (MC-SRM) and analytical techniques in combination with an experimental characterization (AE-SRM). The spatial response of the system, obtained by using the two approaches, was compared with experimental data. The effect of the MC-SRM and AE-SRM approaches on the reconstructed image was assessed in terms of image contrast, signal-to-noise ratio, image quality, and spatial resolution. To this end, acquisitions were carried out using a hot cylinder phantom (consisting of five fillable rods with diameters of 5, 4, 3, 2, and 1 mm and a uniform cylindrical chamber) and a custom-made Derenzo phantom, with center-to-center distances between adjacent rods of 1.5, 2.0, and 3.0 mm. Results: Good agreement was found for the spatial response of the system between measured data and results derived from MC-SRM and AE-SRM. Only minor differences for point sources at distances smaller than the radius of rotation and large incidence angles were found. Assessment of the effect on the reconstructed image showed a similar contrast for both approaches, with values higher than 0.9 for rod diameters greater than 1 mm and higher than 0.8 for rod diameter of 1 mm. The comparison in terms of image quality showed that all rods in the different sections of a custom-made Derenzo phantom could be distinguished. The spatial resolution (FWHM) was 0.7 mm at iteration 100 using both approaches. The SNR was lower for reconstructed images using MC-SRM than for those reconstructed using AE-SRM, indicating that AE-SRM deals better with the

  8. GATE - Geant4 Application for Tomographic Emission: a simulation toolkit for PET and SPECT

    PubMed Central

    Jan, S.; Santin, G.; Strul, D.; Staelens, S.; Assié, K.; Autret, D.; Avner, S.; Barbier, R.; Bardiès, M.; Bloomfield, P. M.; Brasse, D.; Breton, V.; Bruyndonckx, P.; Buvat, I.; Chatziioannou, A. F.; Choi, Y.; Chung, Y. H.; Comtat, C.; Donnarieix, D.; Ferrer, L.; Glick, S. J.; Groiselle, C. J.; Guez, D.; Honore, P.-F.; Kerhoas-Cavata, S.; Kirov, A. S.; Kohli, V.; Koole, M.; Krieguer, M.; van der Laan, D. J.; Lamare, F.; Largeron, G.; Lartizien, C.; Lazaro, D.; Maas, M. C.; Maigne, L.; Mayet, F.; Melot, F.; Merheb, C.; Pennacchio, E.; Perez, J.; Pietrzyk, U.; Rannou, F. R.; Rey, M.; Schaart, D. R.; Schmidtlein, C. R.; Simon, L.; Song, T. Y.; Vieira, J.-M.; Visvikis, D.; Van de Walle, R.; Wieërs, E.; Morel, C.

    2012-01-01

    Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols, and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted simulation toolkit adapted to the field of nuclear medicine. In particular, GATE allows the description of time-dependent phenomena such as source or detector movement, and source decay kinetics. This feature makes it possible to simulate time curves under realistic acquisition conditions and to test dynamic reconstruction algorithms. This paper gives a detailed description of the design and development of GATE by the OpenGATE collaboration, whose continuing objective is to improve, document, and validate GATE by simulating commercially available imaging systems for PET and SPECT. Large effort is also invested in the ability and the flexibility to model novel detection systems or systems still under design. A public release of GATE licensed under the GNU Lesser General Public License can be downloaded at the address http://www-lphe.ep.ch/GATE/. Two benchmarks developed for PET and SPECT to test the installation of GATE and to serve as a tutorial for the users are presented. Extensive validation of the GATE simulation platform has been started, comparing simulations and measurements on commercially available acquisition systems. References to those results are listed. The future prospects toward the gridification of GATE and its extension to other domains such as dosimetry are also discussed. PMID:15552416

  9. The Proton Spectrum in Neutron Beta Decay: Latest Results with the aSPECT Spectrometer

    NASA Astrophysics Data System (ADS)

    Konrad, G.; Ayala Guardia, F.; Baeßler, S.; Borg, M.; Glück, F.; Heil, W.; Konorov, I.; Leung, K. K. H.; Muñoz Horta, R.; Simson, M.; Sobolev, Y.; Soldner, T.; Wirth, H.-F.; Zimmer, O.

    2009-08-01

    The purpose of the neutron decay spectrometer aSPECT is to determine the antineutrino electron angular correlation coefficient a with high precision. Latest measurements with aSPECT were performed during April/May 2008 at the Institut Laue-Langevin in Grenoble, France. In this paper we give a report on the experiment and the status of the ongoing data analysis.

  10. Distinction between hemangioma of the liver and hepatocellular carcinoma: value of labeled RBC-SPECT scanning

    SciTech Connect

    Kudo, M.; Ikekubo, K.; Yamamoto, K.; Ibuki, Y.; Hino, M.; Tomita, S.; Komori, H.; Orino, A.; Todo, A.

    1989-05-01

    The role of adding single-photon emission CT (SPECT) to /sup 99m/Tc-labeled RBC imaging of the liver was evaluated by specifically focusing on the differentiation between hepatic hemangioma and hepatocellular carcinoma. Planar RBC imaging followed by blood-pool SPECT scanning was performed in 77 patients with a total of 108 hemangiomas and in 29 patients with a total of 46 hepatocellular carcinomas. All lesions were smaller than 5 cm in diameter. Thirty-six (33%) of 108 hemangiomas were detected by planar delayed RBC imaging, whereas 63 (58%) were detected by the delayed RBC-SPECT scan. The smallest hemangioma shown by delayed RBC-SPECT scanning was 1.4 cm in diameter, compared with 1.7 cm by planar RBC scanning. When confined to nodules larger than 1.4 cm in diameter, 42% of hemangiomas (36/85) were detected by planar delayed RBC imaging, whereas 74% (63/85) were detected by delayed RBC-SPECT. Increase in sensitivity was noted in nodules 2.1-4.0 cm in diameter. No hepatocellular carcinomas were shown by delayed RBC planar or SPECT scans. We concluded that with the addition of SPECT, the sensitivity of delayed RBC scans in the detection of small hemangiomas is considerably improved. Delayed RBC-SPECT scanning can be used to distinguish hemangioma from hepatocellular carcinoma.

  11. Evaluation of the Effect of Attenuation Correction by External CT in a Semiconductor SPECT.

    PubMed

    Uchibe, Taku; Miyai, Masahiro; Yata, Nobuhiro; Haramoto, Masuo; Yamamoto, Yasushi; Nakamura, Megumi; Kitagaki, Hajime; Takahashi, Yasuyuki

    2016-07-01

    The discovery of NM530c with a cadmium-zinc-telluride detector (CdZnTe-SPECT) is superior to the conventional Anger-type SPECT with a sodium-iodide detector (NaI-SPECT) in terms of sensitivity and spatial resolution. However, in the clinical example, even in CdZnTe-SPECT, a count decrease in myocardium due to the attenuation of the gamma ray is an issue. This study was conducted to evaluate the effect of computed tomography attenuation correction (CTAC) in CdZnTe-SPECT with the help of external CT. We evaluated the revision effect of uniformity, influence by the difference in attenuation distance, contrast ratio, an uptake rate using the heart phantom. As a result of the phantom studies, a good revision effect was obtained. In the clinical study, there was a statistical significant difference between the contrast ratio before and after CTAC in the inferior wall. In addition, the contrast ratio before and after CTAC in CdZnTe-SPECT image was equal to those of NaI-SPECT image. It was suggested that CTAC using external CT in CdZnTe-SPECT was clinically useful for inferior wall. PMID:27440705

  12. Complexity and accuracy of image registration methods in SPECT-guided radiation therapy

    NASA Astrophysics Data System (ADS)

    Yin, L. S.; Tang, L.; Hamarneh, G.; Gill, B.; Celler, A.; Shcherbinin, S.; Fua, T. F.; Thompson, A.; Liu, M.; Duzenli, C.; Sheehan, F.; Moiseenko, V.

    2010-01-01

    The use of functional imaging in radiotherapy treatment (RT) planning requires accurate co-registration of functional imaging scans to CT scans. We evaluated six methods of image registration for use in SPECT-guided radiotherapy treatment planning. Methods varied in complexity from 3D affine transform based on control points to diffeomorphic demons and level set non-rigid registration. Ten lung cancer patients underwent perfusion SPECT-scans prior to their radiotherapy. CT images from a hybrid SPECT/CT scanner were registered to a planning CT, and then the same transformation was applied to the SPECT images. According to registration evaluation measures computed based on the intensity difference between the registered CT images or based on target registration error, non-rigid registrations provided a higher degree of accuracy than rigid methods. However, due to the irregularities in some of the obtained deformation fields, warping the SPECT using these fields may result in unacceptable changes to the SPECT intensity distribution that would preclude use in RT planning. Moreover, the differences between intensity histograms in the original and registered SPECT image sets were the largest for diffeomorphic demons and level set methods. In conclusion, the use of intensity-based validation measures alone is not sufficient for SPECT/CT registration for RTTP. It was also found that the proper evaluation of image registration requires the use of several accuracy metrics.

  13. SPECT-OPT multimodal imaging enables accurate evaluation of radiotracers for β-cell mass assessments

    PubMed Central

    Eter, Wael A.; Parween, Saba; Joosten, Lieke; Frielink, Cathelijne; Eriksson, Maria; Brom, Maarten; Ahlgren, Ulf; Gotthardt, Martin

    2016-01-01

    Single Photon Emission Computed Tomography (SPECT) has become a promising experimental approach to monitor changes in β-cell mass (BCM) during diabetes progression. SPECT imaging of pancreatic islets is most commonly cross-validated by stereological analysis of histological pancreatic sections after insulin staining. Typically, stereological methods do not accurately determine the total β-cell volume, which is inconvenient when correlating total pancreatic tracer uptake with BCM. Alternative methods are therefore warranted to cross-validate β-cell imaging using radiotracers. In this study, we introduce multimodal SPECT - optical projection tomography (OPT) imaging as an accurate approach to cross-validate radionuclide-based imaging of β-cells. Uptake of a promising radiotracer for β-cell imaging by SPECT, 111In-exendin-3, was measured by ex vivo-SPECT and cross evaluated by 3D quantitative OPT imaging as well as with histology within healthy and alloxan-treated Brown Norway rat pancreata. SPECT signal was in excellent linear correlation with OPT data as compared to histology. While histological determination of islet spatial distribution was challenging, SPECT and OPT revealed similar distribution patterns of 111In-exendin-3 and insulin positive β-cell volumes between different pancreatic lobes, both visually and quantitatively. We propose ex vivo SPECT-OPT multimodal imaging as a highly accurate strategy for validating the performance of β-cell radiotracers. PMID:27080529

  14. SPECT assay of radiolabeled monoclonal antibodies. Final performance report, March 1992--November 1995

    SciTech Connect

    Jaszczak, R.J.

    1995-12-01

    Research is described in the following areas: development and evaluation quantitatively of reconstruction algorithms with improved compensations for attenuation, scatter, and geometric collimator response; evaluation of single photon emission computed tomography (SPECT) quantification of iodine 123 and astatine 211; and the development and evaluation of SPECT pinhole imaging for low and medium energy photons.

  15. SPECT functional neuroimaging in patients with AIDS

    SciTech Connect

    Bushnell, D.L.; Eastman, G.R. )

    1989-09-01

    This is the third in a four-part article series on AIDS. Upon completion of this article, the technologist will have an understanding of the neurological complications of the AIDS virus and how nuclear medicine techniques can be used for early detection of CNS disorders.

  16. Neuronavigation. Principles. Surgical technique.

    PubMed

    Ivanov, Marcel; Ciurea, Alexandru Vlad

    2009-01-01

    Neuronavigation and stereotaxy are techniques designed to help neurosurgeons precisely localize different intracerebral pathological processes by using a set of preoperative images (CT, MRI, fMRI, PET, SPECT etc.). The development of computer assisted surgery was possible only after a significant technological progress, especially in the area of informatics and imagistics. The main indications of neuronavigation are represented by the targeting of small and deep intracerebral lesions and choosing the best way to treat them, in order to preserve the neurological function. Stereotaxis also allows lesioning or stimulation of basal ganglia for the treatment of movement disorders. These techniques can bring an important amount of confort both to the patient and to the neurosurgeon. Neuronavigation was introduced in Romania around 2003, in four neurosurgical centers. We present our five-years experience in neuronavigation and describe the main principles and surgical techniques.

  17. Neuronavigation. Principles. Surgical technique.

    PubMed

    Ivanov, Marcel; Ciurea, Alexandru Vlad

    2009-01-01

    Neuronavigation and stereotaxy are techniques designed to help neurosurgeons precisely localize different intracerebral pathological processes by using a set of preoperative images (CT, MRI, fMRI, PET, SPECT etc.). The development of computer assisted surgery was possible only after a significant technological progress, especially in the area of informatics and imagistics. The main indications of neuronavigation are represented by the targeting of small and deep intracerebral lesions and choosing the best way to treat them, in order to preserve the neurological function. Stereotaxis also allows lesioning or stimulation of basal ganglia for the treatment of movement disorders. These techniques can bring an important amount of confort both to the patient and to the neurosurgeon. Neuronavigation was introduced in Romania around 2003, in four neurosurgical centers. We present our five-years experience in neuronavigation and describe the main principles and surgical techniques. PMID:20108488

  18. Automatic estimation of detector radial position for contoured SPECT acquisition using CT images on a SPECT/CT system.

    PubMed

    Liu, Ruijie Rachel; Erwin, William D

    2006-08-01

    An algorithm was developed to estimate noncircular orbit (NCO) single-photon emission computed tomography (SPECT) detector radius on a SPECT/CT imaging system using the CT images, for incorporation into collimator resolution modeling for iterative SPECT reconstruction. Simulated male abdominal (arms up), male head and neck (arms down) and female chest (arms down) anthropomorphic phantom, and ten patient, medium-energy SPECT/CT scans were acquired on a hybrid imaging system. The algorithm simulated inward SPECT detector radial motion and object contour detection at each projection angle, employing the calculated average CT image and a fixed Hounsfield unit (HU) threshold. Calculated radii were compared to the observed true radii, and optimal CT threshold values, corresponding to patient bed and clothing surfaces, were found to be between -970 and -950 HU. The algorithm was constrained by the 45 cm CT field-of-view (FOV), which limited the detected radii to < or = 22.5 cm and led to occasional radius underestimation in the case of object truncation by CT. Two methods incorporating the algorithm were implemented: physical model (PM) and best fit (BF). The PM method computed an offset that produced maximum overlap of calculated and true radii for the phantom scans, and applied that offset as a calculated-to-true radius transformation. For the BF method, the calculated-to-true radius transformation was based upon a linear regression between calculated and true radii. For the PM method, a fixed offset of +2.75 cm provided maximum calculated-to-true radius overlap for the phantom study, which accounted for the camera system's object contour detect sensor surface-to-detector face distance. For the BF method, a linear regression of true versus calculated radius from a reference patient scan was used as a calculated-to-true radius transform. Both methods were applied to ten patient scans. For -970 and -950 HU thresholds, the combined overall average root-mean-square (rms

  19. Experimental studies of SPECT scintimammography with combined cone-beam and parallel-beam collimators

    NASA Astrophysics Data System (ADS)

    Krol, Andrzej; Feiglin, David H.; Gangal, K. R.; Coman, Ioana L.; Salgado, Roberto B.; Lipson, Edward D.; Karczewski, Deborah A.; Thomas, Frank D.

    2003-05-01

    Conventional SPECT Tc-99m sestamibi scintimammography (STSM) has limited clinical utility due to fairly low radiopharmaceutical uptake in the breast tissue as compared to the heart and the liver. We investigated the use of a cone-beam collimator (CBC) to STSM. Each detector on a multi-headed gamma camera can be equipped with parallel-beam (PBC) or cone-beam collimators (CBC). PBC can provide truncation-free SPECT projection sets, while CBC offers increased sensitivity in a limited field-of-view (FOV). Combined PBC and CBC SPECT ddata acquisition may provide improved lesion contrast and overall better imaging performance within CBC FOV with significantly reduced truncation artifacts in the reconstructed images. In this paper we evaluate the combined CBC&PBC SPECT method using a limited number of confirmed breast cancer patients and female chest phantoms with simulated breast lesions. We envision the combined CBC&PBC SPECT as a useful clinical tool in scintimammography.

  20. 3D scintigraphic imaging and navigation in radioguided surgery: freehand SPECT technology and its clinical applications.

    PubMed

    Bluemel, Christina; Matthies, Philipp; Herrmann, Ken; Povoski, Stephen P

    2016-01-01

    Freehand SPECT (fhSPECT) is a technology platform for providing 3-dimensional (3D) navigation for radioguided surgical procedures, such as sentinel lymph node (SLN) biopsy (SLNB). In addition to the information provided by conventional handheld gamma detection probes, fhSPECT allows for direct visualization of the distribution of radioactivity in any given region of interest, allowing for improved navigation to radioactive target lesions and providing accurate lesion depth measurements. Herein, we will review the currently available clinical data on the use of fhSPECT: (i) for SLNB of various malignancies, including difficult-to-detect SLNs, and (ii) for radioguided localization of solid tumors. Moreover, the combination of fhSPECT with other technologies (e.g., small field-of-view gamma cameras, and diagnostic ultrasound) is discussed. These technical advances have the potential to greatly expand the clinical application of radioguided surgery in the future. PMID:26878667

  1. Comparison of thallium 201 (TL) SPECT and F-18 fluoro-deoxyglucose (FDG) PET in the evaluation of MRI lesions in patients with gliomas after therapy

    SciTech Connect

    Wong, F.C.L.; Garcia, J.R.; Yung, W.K.A.

    1994-05-01

    Although both Tl-201 SPECT and F-18 FDG PET are helpful for the detection of recurrent gliomas, there is DO comparative study of these techniques for the same patient group. This study is performed to compare the efficacy of TL SPECT and FDG PET in differentiating recurrent glioma from post-treatment necrosis. Twenty patients (16M/4 F) treated for gliomas (surgery, radiation and/or chemotherapy) with 24 instructive MRI enhancing lesions underwent TL-201 SPECT and F-18 FDG PET within 1 week. The lesions were graded 0 to 4 (by consensus of three nuclear radiologists) with increasing confidence for recurrent tumors. Semiquantitative evaluations include lesion/scalp TL-201 ratios (L/S TL) and lesion/cortex F-18 FDG (L/C FDG) standard uptake value ratios. With clinical follow-up (12/24) and histopathologic confirmation (12/24), sensitivity and specificity for each grade were used to construct the receiver-operator-characteristic (ROC) curve for comparison. Recurrent gliomas were confirmed in 12/24 lesions (9/12 by pathology; 3/12 by follow-up). Post-treatment necrosis was confirmed in 12/24 lesions (9/12 by follow-up; 3/12 by pathology). The L/S TL ratios were [1.99{plus_minus}0.77] for gliomas and [1.14{plus_minus}0.22] for necrosis; the L/C FDG ratios were 0.86{plus_minus}0.43 for gliomas and 0.43{plus_minus}0.15 for necrosis. Although none of the semiquantitative measurements from TL SPECT and FDG PET could completely distinguish gliomas from post-treatment necrosis, FDG PET was superior to TL SPECT on the ROC curves. While TL-201 SPECT and F-18 FDG PET provide different and probably complementary metabolic measurements of brain lesions, this preliminary work suggests FDG PET is a better tool to evaluate enhancing MRI lesions in patients with treated gliomas. Further confirmation will require studies of more patients.

  2. Post-reconstruction non-local means filtering methods using CT side information for quantitative SPECT

    NASA Astrophysics Data System (ADS)

    Chun, Se Young; Fessler, Jeffrey A.; Dewaraja, Yuni K.

    2013-09-01

    Quantitative SPECT techniques are important for many applications including internal emitter therapy dosimetry where accurate estimation of total target activity and activity distribution within targets are both potentially important for dose-response evaluations. We investigated non-local means (NLM) post-reconstruction filtering for accurate I-131 SPECT estimation of both total target activity and the 3D activity distribution. We first investigated activity estimation versus number of ordered-subsets expectation-maximization (OSEM) iterations. We performed simulations using the XCAT phantom with tumors containing a uniform and a non-uniform activity distribution, and measured the recovery coefficient (RC) and the root mean squared error (RMSE) to quantify total target activity and activity distribution, respectively. We observed that using more OSEM iterations is essential for accurate estimation of RC, but may or may not improve RMSE. We then investigated various post-reconstruction filtering methods to suppress noise at high iteration while preserving image details so that both RC and RMSE can be improved. Recently, NLM filtering methods have shown promising results for noise reduction. Moreover, NLM methods using high-quality side information can improve image quality further. We investigated several NLM methods with and without CT side information for I-131 SPECT imaging and compared them to conventional Gaussian filtering and to unfiltered methods. We studied four different ways of incorporating CT information in the NLM methods: two known (NLM CT-B and NLM CT-M) and two newly considered (NLM CT-S and NLM CT-H). We also evaluated the robustness of NLM filtering using CT information to erroneous CT. NLM CT-S and NLM CT-H yielded comparable RC values to unfiltered images while substantially reducing RMSE. NLM CT-S achieved -2.7 to 2.6% increase of RC compared to no filtering and NLM CT-H yielded up to 6% decrease in RC while other methods yielded lower RCs

  3. Design and performance of a multi-pinhole collimation device for small animal imaging with clinical SPECT and SPECT-CT scanners.

    PubMed

    Difilippo, Frank P

    2008-08-01

    A multi-pinhole collimation device is developed that uses the gamma camera detectors of a clinical SPECT or SPECT-CT scanner to produce high-resolution SPECT images. The device consists of a rotating cylindrical collimator having 22 tungsten pinholes with 0.9 mm diameter apertures and an animal bed inside the collimator that moves linearly to provide helical or ordered-subsets axial sampling. CT images also may be acquired on a SPECT-CT scanner for purposes of image co-registration and SPECT attenuation correction. The device is placed on the patient table of the scanner without attaching to the detectors or scanner gantry. The system geometry is calibrated in-place from point source data and is then used during image reconstruction. The SPECT imaging performance of the device is evaluated with test phantom scans. Spatial resolution from reconstructed point source images is measured to be 0.6 mm full width at half maximum or better. Micro-Derenzo phantom images demonstrate the ability to resolve 0.7 mm diameter rod patterns. The axial slabs of a Micro-Defrise phantom are visualized well. Collimator efficiency exceeds 0.05% at the center of the field of view, and images of a uniform phantom show acceptable uniformity and minimal artifact. The overall simplicity and relatively good imaging performance of the device make it an interesting low-cost alternative to dedicated small animal scanners.

  4. Impact of reconstruction parameters on quantitative I-131 SPECT

    NASA Astrophysics Data System (ADS)

    van Gils, C. A. J.; Beijst, C.; van Rooij, R.; de Jong, H. W. A. M.

    2016-07-01

    Radioiodine therapy using I-131 is widely used for treatment of thyroid disease or neuroendocrine tumors. Monitoring treatment by accurate dosimetry requires quantitative imaging. The high energy photons however render quantitative SPECT reconstruction challenging, potentially requiring accurate correction for scatter and collimator effects. The goal of this work is to assess the effectiveness of various correction methods on these effects using phantom studies. A SPECT/CT acquisition of the NEMA IEC body phantom was performed. Images were reconstructed using the following parameters: (1) without scatter correction, (2) with triple energy window (TEW) scatter correction and (3) with Monte Carlo-based scatter correction. For modelling the collimator-detector response (CDR), both (a) geometric Gaussian CDRs as well as (b) Monte Carlo simulated CDRs were compared. Quantitative accuracy, contrast to noise ratios and recovery coefficients were calculated, as well as the background variability and the residual count error in the lung insert. The Monte Carlo scatter corrected reconstruction method was shown to be intrinsically quantitative, requiring no experimentally acquired calibration factor. It resulted in a more accurate quantification of the background compartment activity density compared with TEW or no scatter correction. The quantification error relative to a dose calibrator derived measurement was found to be  <1%,-26% and 33%, respectively. The adverse effects of partial volume were significantly smaller with the Monte Carlo simulated CDR correction compared with geometric Gaussian or no CDR modelling. Scatter correction showed a small effect on quantification of small volumes. When using a weighting factor, TEW correction was comparable to Monte Carlo reconstruction in all measured parameters, although this approach is clinically impractical since this factor may be patient dependent. Monte Carlo based scatter correction including accurately simulated CDR

  5. A new reconstruction strategy for image improvement in pinhole SPECT.

    PubMed

    Zeniya, Tsutomu; Watabe, Hiroshi; Aoi, Toshiyuki; Kim, Kyeong Min; Teramoto, Noboru; Hayashi, Takuya; Sohlberg, Antti; Kudo, Hiroyuki; Iida, Hidehiro

    2004-08-01

    Pinhole single-photon emission computed tomography (SPECT) is able to provide information on the biodistribution of several radioligands in small laboratory animals, but has limitations associated with non-uniform spatial resolution or axial blurring. We have hypothesised that this blurring is due to incompleteness of the projection data acquired by a single circular pinhole orbit, and have evaluated a new strategy for accurate image reconstruction with better spatial resolution uniformity. A pinhole SPECT system using two circular orbits and a dedicated three-dimensional ordered subsets expectation maximisation (3D-OSEM) reconstruction method were developed. In this system, not the camera but the object rotates, and the two orbits are at 90 degrees and 45 degrees relative to the object's axis. This system satisfies Tuy's condition, and is thus able to provide complete data for 3D pinhole SPECT reconstruction within the whole field of view (FOV). To evaluate this system, a series of experiments was carried out using a multiple-disk phantom filled with 99mTc solution. The feasibility of the proposed method for small animal imaging was tested with a mouse bone study using 99mTc-hydroxymethylene diphosphonate. Feldkamp's filtered back-projection (FBP) method and the 3D-OSEM method were applied to these data sets, and the visual and statistical properties were examined. Axial blurring, which was still visible at the edge of the FOV even after applying the conventional 3D-OSEM instead of FBP for single-orbit data, was not visible after application of 3D-OSEM using two-orbit data. 3D-OSEM using two-orbit data dramatically reduced the resolution non-uniformity and statistical noise, and also demonstrated considerably better image quality in the mouse scan. This system may be of use in quantitative assessment of bio-physiological functions in small animals.

  6. Impact of subcortical white matter lesions on dopamine transporter SPECT.

    PubMed

    Funke, Elisabeth; Kupsch, Andreas; Buchert, Ralph; Brenner, Winfried; Plotkin, Michail

    2013-07-01

    Subcortical arteriosclerotic encephalopathy (SAE) can affect the nigrostriatal system and presumably cause vascular parkinsonism (VP). However, in patients with SAE, the differentiation of VP from idiopathic Parkinson's disease (IPS) is challenging. The aim of the present study was to examine the striatal dopamine transporter (DAT) density in patients with parkinsonism and SAE. Fifteen consecutive patients with parkinsonian symptoms displayed SAE, as detected by magnetic resonance imaging (MRI). Fifteen retrospectively chosen, matched patients with diagnosis of IPS without any abnormalities in MRI served as a reference group. DAT SPECT was performed using the tracer ¹²³I-FP-CIT. Scans were acquired on a triple-head SPECT system (Multispect 3, Siemens) and analysed using the investigator-independent BRASS™ software (HERMES). In the SAE group, a DAT deficit was observed in 9/15 patients. In contrast, all patients from the IPS group showed a reduced DAT binding (p = 0.008). The specific binding ratios (BR) of putamen contralateral to the side of the more affected limb versus occipital lobe were in trend higher in patients with SAE versus patients in the IPS-group (p = 0.053). Indices for putaminal asymmetry (p = 0.036) and asymmetry caudate-to-putamen (p = 0.026) as well as the ratio caudate-to-putamen (p = 0.048) were significantly higher in IPS patients having no SAE. DAT deficit was less pronounced in patients with SAE and parkinsonism than in patients with IPS without any abnormalities in the MRI. A potential role of DAT SPECT in the differential diagnosis of VP and IPS requires more assessments within prospective studies.

  7. Impact of reconstruction parameters on quantitative I-131 SPECT

    NASA Astrophysics Data System (ADS)

    van Gils, C. A. J.; Beijst, C.; van Rooij, R.; de Jong, H. W. A. M.

    2016-07-01

    Radioiodine therapy using I-131 is widely used for treatment of thyroid disease or neuroendocrine tumors. Monitoring treatment by accurate dosimetry requires quantitative imaging. The high energy photons however render quantitative SPECT reconstruction challenging, potentially requiring accurate correction for scatter and collimator effects. The goal of this work is to assess the effectiveness of various correction methods on these effects using phantom studies. A SPECT/CT acquisition of the NEMA IEC body phantom was performed. Images were reconstructed using the following parameters: (1) without scatter correction, (2) with triple energy window (TEW) scatter correction and (3) with Monte Carlo-based scatter correction. For modelling the collimator-detector response (CDR), both (a) geometric Gaussian CDRs as well as (b) Monte Carlo simulated CDRs were compared. Quantitative accuracy, contrast to noise ratios and recovery coefficients were calculated, as well as the background variability and the residual count error in the lung insert. The Monte Carlo scatter corrected reconstruction method was shown to be intrinsically quantitative, requiring no experimentally acquired calibration factor. It resulted in a more accurate quantification of the background compartment activity density compared with TEW or no scatter correction. The quantification error relative to a dose calibrator derived measurement was found to be  <1%,‑26% and 33%, respectively. The adverse effects of partial volume were significantly smaller with the Monte Carlo simulated CDR correction compared with geometric Gaussian or no CDR modelling. Scatter correction showed a small effect on quantification of small volumes. When using a weighting factor, TEW correction was comparable to Monte Carlo reconstruction in all measured parameters, although this approach is clinically impractical since this factor may be patient dependent. Monte Carlo based scatter correction including accurately simulated

  8. Multipinhole collimator with 20 apertures for a brain SPECT application

    SciTech Connect

    Lee, Tzu-Cheng; Ellin, Justin R.; Shrestha, Uttam; Seo, Youngho; Huang, Qiu; Gullberg, Grant T.

    2014-11-01

    Purpose: Several new technologies for single photon emission computed tomography (SPECT) instrumentation with parallel-hole collimation have been proposed to improve detector sensitivity and signal collection efficiency. Benefits from improved signal efficiency include shorter acquisition times and lower dose requirements. In this paper, the authors show a possibility of over an order of magnitude enhancement in photon detection efficiency (from 7.6 × 10{sup −5} to 1.6 × 10{sup −3}) for dopamine transporter (DaT) imaging of the striatum over the conventional SPECT parallel-hole collimators by use of custom-designed 20 multipinhole (20-MPH) collimators with apertures of 0.75 cm diameter. Methods: Quantifying specific binding ratio (SBR) of {sup 123}I-ioflupane or {sup 123}I-iometopane’s signal at the striatal region is a common brain imaging method to confirm the diagnosis of the Parkinson’s disease. The authors performed imaging of a striatal phantom filled with aqueous solution of I-123 and compared camera recovery ratios of SBR acquired between low-energy high-resolution (LEHR) parallel-hole collimators and 20-MPH collimators. Results: With only two-thirds of total acquisition time (20 min against 30 min), a comparable camera recovery ratio of SBR was achieved using 20-MPH collimators in comparison to that from the LEHR collimator study. Conclusions: Their systematic analyses showed that the 20-MPH collimator could be a promising alternative for the DaT SPECT imaging for brain over the traditional LEHR collimator, which could give both shorter scan time and improved diagnostic accuracy.

  9. Design of multipinhole collimators for small animal SPECT

    SciTech Connect

    Mark Smith; Steve Meikle; Stanislaw Majewski; Andrew Weisenberger

    2003-10-01

    High resolution single photon emission computed tomography (SPECT) of small animals with pinhole collimators is hampered by poor sensitivity. For the target application of imaging the brain of an unanesthetized, unrestrained mouse, the design of multipinhole collimators for small, compact gamma cameras was studied using numerical simulations. The collimators were designed to image the mouse at different axial positions inside a tube aligned with the axis of rotation (AOR) of the SPECT system. The proposed system consisted of a 10 cm/spl times/20 cm pixelated detector with 2 cm from the AOR to the collimator mask and a focal length of 7 cm for a magnification of 3.5 on the AOR. A digital mouse phantom was created with a brain:background activity concentration ratio of 8:1. The brain region contained small disks and hot and cool cylinders for contrast and signal-to-noise ratio (SNR) quantitation. SPECT projection data were simulated at 120 angles for four pinhole masks having 1, 5 and two arrangements of 13 pinholes. Projections were scaled to model a 30 min study with doses of 0.3, 1 and 3 mCi in the mouse. Images were reconstructed with an iterative ordered subset expectation maximization (OSEM) algorithm. The peak SNR improved with multipinhole collimation compared with single pinhole imaging when there was no increased activity in the liver or bladder. With such activity, peak SNR was about the same for all collimators. For all cases peak SNR occurred at higher contrast values with multipinhole collimation. The extended axial range of multipinhole arrays enabled the mouse brain to be imaged with decreased axial blurring when the mouse was translated axially. These results suggest that mouse brains can be successfully imaged at realistic activity levels with multipinhole arrays and projection data multiplexing.

  10. High Sensitivity SPECT for Small Animals and Plants

    SciTech Connect

    Mitchell, Gregory S.

    2015-02-28

    Imaging systems using single gamma-ray emitting radioisotopes typically implement collimators in order to form the images. However, a tradeoff in sensitivity is inherent in the use of collimators, and modern preclinical single-photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma-rays (<0.3%). We have built a collimator-less system, which can reach sensitivity of 40% for 99mTc imaging, while still producing images of sufficient spatial resolution for certain applications in thin objects such as mice, small plants, and well plates used for in vitro experiments.

  11. Robin Hood caught in Wonderland: brain SPECT findings.

    PubMed

    Morland, David; Wolff, Valérie; Dietemann, Jean-Louis; Marescaux, Christian; Namer, Izzie Jacques

    2013-12-01

    We present the case of a 53-year-old woman presenting several episodes of body image distortions, ground deformation illusions, and problems assessing distance in the orthostatic position corresponding to the Alice in Wonderland syndrome. No symptoms were reported when sitting or lying down. She had uncontrolled hypertension, hyperglycemia, hypercholesterolemia, and a history of head trauma. Her condition had been diagnosed with left internal carotid artery dissection 2 years earlier. Brain SPECT with 99mTc-ECD performed after i.v. injection of the radiotracer in supine and in standing positions showed hypoperfusion in the healthy contralateral frontoparietal operculum (Robin Hood syndrome), deteriorating when standing up. PMID:24152648

  12. Hybrid SPECT/CT evaluation of Marine-Lenhart syndrome.

    PubMed

    Harisankar, Chidambaram Natrajan Balasubramanian; Preethi, Govindababu Rajalakshmi; Chungath, Biju Baby

    2013-02-01

    Marine-Lenhart syndrome has been described as a variant of Graves disease with the following criteria: (1) the thyroid scan shows an enlarged gland and 1 or 2 poorly functioning nodules; (2) the nodule is TSH dependent and the paranodular tissue is TSH independent; (3) after endogenous or exogenous TSH stimulation, the return of function in the nodule can be demonstrated; and (4) the nodule is histologically benign. We report a 57-year-old woman with Marine-Lenhart syndrome evaluated with technetium scanning and hybrid SPECT/CT. PMID:23334146

  13. Reproducibility of area at risk assessment in acute myocardial infarction by T1- and T2-mapping sequences in cardiac magnetic resonance imaging in comparison to Tc99m-sestamibi SPECT.

    PubMed

    Langhans, Birgit; Nadjiri, Jonathan; Jähnichen, Christin; Kastrati, Adnan; Martinoff, Stefan; Hadamitzky, Martin

    2014-10-01

    Area at risk (AAR) is an important parameter for the assessment of the salvage area after revascularization in acute myocardial infarction (AMI). By combining AAR assessment by T2-weighted imaging and scar quantification by late gadolinium enhancement imaging cardiovascular magnetic resonance (CMR) offers a promising alternative to the "classical" modality of Tc99m-sestamibi single photon emission tomography (SPECT). Current T2 weighted sequences for edema imaging in CMR are limited by low contrast to noise ratios and motion artifacts. During the last years novel CMR imaging techniques for quantification of acute myocardial injury, particularly the T1-mapping and T2-mapping, have attracted rising attention. But no direct comparison between the different sequences in the setting of AMI or a validation against SPECT has been reported so far. We analyzed 14 patients undergoing primary coronary revascularization in AMI in whom both a pre-intervention Tc99m-sestamibi-SPECT and CMR imaging at a median of 3.4 (interquartile range 3.3-3.6) days after the acute event were performed. Size of AAR was measured by three different non-contrast CMR techniques on corresponding short axis slices: T2-weighted, fat-suppressed turbospin echo sequence (TSE), T2-mapping from T2-prepared balanced steady state free precession sequences (T2-MAP) and T1-mapping from modified look locker inversion recovery (MOLLI) sequences. For each CMR sequence, the AAR was quantified by appropriate methods (absolute values for mapping sequences, comparison with remote myocardium for other sequences) and correlated with Tc99m-sestamibi-SPECT. All measurements were performed on a 1.5 Tesla scanner. The size of the AAR assessed by CMR was 28.7 ± 20.9 % of left ventricular myocardial volume (%LV) for TSE, 45.8 ± 16.6 %LV for T2-MAP, and 40.1 ± 14.4 %LV for MOLLI. AAR assessed by SPECT measured 41.6 ± 20.7 %LV. Correlation analysis revealed best correlation with SPECT for T2-MAP at a T2-threshold of 60 ms

  14. Computer-assisted superimposition of magnetic resonance and high-resolution technetium-99m-HMPAO and thallium-201 SPECT images of the brain

    SciTech Connect

    Holman, B.L.; Zimmerman, R.E.; Johnson, K.A.; Carvalho, P.A.; Schwartz, R.B.; Loeffler, J.S.; Alexander, E.; Pelizzari, C.A.; Chen, G.T. )

    1991-08-01

    A method for registering three-dimensional CT, MR, and PET data sets that require no special patient immobilization or other precise positioning measures was adapted to high-resolution SPECT and MRI and was applied in 14 subjects (five normal volunteers, four patients with dementia (Alzheimer's disease), two patients with recurrent glioblastoma, and three patients with focal lesions (stroke, arachnoid cyst and head trauma)). T2-weighted axial magnetic resonance images and transaxial 99mTc-HMPAO and 201Tl images acquired with an annular gamma camera were merged using an objective registration (translation, rotation and rescaling) program. In the normal subjects and patients with dementia and focal lesions, focal areas of high uptake corresponded to gray matter structures. Focal lesions observed on MRI corresponded to perfusion defects on SPECT. In the patients who had undergone surgical resection of glioblastoma followed by interstitial brachytherapy, increased 201Tl corresponding to recurrent tumor could be localized from the superimposed images. The method was evaluated by measuring the residuals in all subjects and translational errors due to superimposition of deep structures in the 12 subjects with normal thalamic anatomy and 99mTc-HMPAO uptake. This method for superimposing magnetic resonance and high-resolution SPECT images of the brain is a useful technique for correlating regional function with brain anatomy.

  15. High-Resolution Anamorphic SPECT Imaging

    PubMed Central

    Durko, Heather L.; Barrett, Harrison H.; Furenlid, Lars R.

    2015-01-01

    We have developed a gamma-ray imaging system that combines a high-resolution silicon detector with two sets of movable, half-keel-edged copper-tungsten blades configured as crossed slits. These apertures can be positioned independently between the object and detector, producing an anamorphic image in which the axial and transaxial magnifications are not constrained to be equal. The detector is a 60 mm × 60 mm, one-millimeter-thick, one-megapixel silicon double-sided strip detector with a strip pitch of 59 μm. The flexible nature of this system allows the application of adaptive imaging techniques. We present system details; calibration, acquisition, and reconstruction methods; and imaging results. PMID:26160983

  16. Structure of the Essential Plasmodium Host Cell Traversal Protein SPECT1

    PubMed Central

    Hamaoka, Brent Y.; Ghosh, Partho

    2014-01-01

    Host cell traversal by Plasmodium, the protozoan cause of malaria, is an essential part of this parasite's virulence. In this process, the parasite enters a host cell through a parasite-induced pore, traverses the host cell, and then exits the host cell. Two P. berghei proteins, SPECT1 and SPECT2, are required for host cell traversal by the sporozoite form of the parasite. In the absence of either, no pore formation is observed. While SPECT2 has sequence homology to pore-forming proteins, SPECT1 has no homology to proteins of known structure or function. Here we present the 2.75 Å resolution structure of a slightly truncated version of P. berghei SPECT1. The structure reveals that the protein forms a four-helix bundle, with the rare feature of having all of these helices in parallel or antiparallel alignment. Also notable is the presence of a large, conserved, hydrophobic internal cavity in the protein, which may constitute a ligand-binding site or be indicative of partial instability in SPECT1, or both. The structure of SPECT1 will make possible targeted mutagenesis experiments aimed at understanding its mechanism of action in host cell traversal. PMID:25479287

  17. 123I-MIBG SPECT for Evaluation of Patients with Heart Failure.

    PubMed

    Dimitriu-Leen, Aukelien C; Scholte, Arthur J H A; Jacobson, Arnold F

    2015-06-01

    Heart failure (HF) is characterized by activation of the sympathetic cardiac nerves. The condition of cardiac sympathetic nerves can be evaluated by (123)I-metaiodobenzylguanidine ((123)I-MIBG) imaging. Most cardiac (123)I-MIBG studies have relied on measurements from anterior planar images of the chest. However, it has become progressively more common to include SPECT imaging in clinical and research protocols. This review examines recent trends in (123)I-MIBG SPECT imaging and evidence that provides the basis for the increased use of the procedure in the clinical management of patients with HF. (123)I-MIBG SPECT has been shown to be complementary to planar imaging in patients with HF in studies of coronary artery disease after an acute myocardial infarction. Moreover, (123)I-MIBG SPECT has been used in numerous studies to document regional denervation for arrhythmic event risk assessment. For better quantification of the size and severity of innervation abnormalities in (123)I-MIBG SPECT, programs and protocols specifically for (123)I have been developed. Also, the introduction of new solid-state cameras has created the potential for more rapid SPECT acquisitions or a reduction in radiopharmaceutical activity. Although PET imaging has superior quantitative capabilities, (123)I-MIBG SPECT is, for the foreseeable future, the only widely available nuclear imaging method for assessing regional myocardial sympathetic innervation.

  18. SPECT with N-isopropyl-p iodoamphetamine in occlusive cerebrovascular diseases.

    PubMed

    Higa, T; Tanaka, T; Ikekubo, K; Komatsu, T; Torizuka, K

    1986-12-01

    The role of SPECT imaging with N-isopropyl-p iodoamphetamine (I-123 IMP) in the detection of angiographically documented occlusive cerebrovascular diseases was evaluated in 24 patients, and the results of regional cerebral blood flow (rCBF) were compared with x-ray CT. Twelve patients had internal carotid occlusion, ten had intracranial occlusion beyond the circle of Willis, one had common carotid occlusion, and one had basilar artery occlusion. SPECT images were obtained with a gamma camera, which was rotated 360 degrees around the patient's head 30 minutes after an intravenous injection of 3 mCi of I-123 IMP. CT images in the transverse plane were obtained, and the regions of reduced attenuation were identified for comparison of topographic extension of the lesion with the regions of decreased rCBF seen on SPECT. In six cases, the lesions seen on the SPECT images were distinctly more extensive than those seen on CT. In the remaining 18 cases, the extent of the lesion was identical on both CT and SPECT images. Radiochemical and radionuclide impurities, the distance of the detector from the head, and the nature of the collimator affected the SPECT results. I-123 IMP SPECT imaging complements CT findings in detecting the ischemic zones beyond the regions identified on CT images, and may have a major rule in the management of patients with occlusive cerebrovascular diseases.

  19. Optimization of detection geometry for industrial SPECT by Monte Carlo simulations

    NASA Astrophysics Data System (ADS)

    Park, J. G.; Kim, C. H.; Han, M. C.; Jung, S. H.; Kim, J. B.; Moon, J.

    2013-04-01

    The Korea Atomic Energy Research Institute (KAERI) has developed an industrial SPECT to investigate the fluid flow and mixing patterns in columns. It has been found that the industrial SPECT is indeed a very powerful tool to study the hydrodynamics in multiphase reactors. One of the practical issues in the development of industrial SPECTs is to achieve a required imaging resolution of an industrial SPECT with a minimum number of component detectors, the number of which is frequently limited by both the size of the detectors and the total cost of the imaging system. In the present study, a set of different geometries of industrial SPECTs were evaluated by Monte Carlo simulation using MCNPX to determine the minimum number of detectors that will provide a spatial resolution that corresponds to 10% of the cylindrical column diameter. Our results show that 11 and 12 detectors will satisfy the 10% resolution requirement for the 40 cm and 60 cm diameter columns, respectively, for the industrial SPECT and radioisotopes considered in the present study. The conclusion of this result is valid only for the case considered in the present study, but we believe that the same procedure can be applied to other industrial SPECTs for this kind of optimization.

  20. Longitudinal Evaluation of Fatty Acid Metabolism in Normal and Spontaneously Hypertensive Rat Hearts with Dynamic MicroSPECT Imaging

    DOE PAGESBeta

    Reutter, Bryan W.; Huesman, Ronald H.; Brennan, Kathleen M.; Boutchko, Rostyslav; Hanrahan, Stephen M.; Gullberg, Grant T.

    2011-01-01

    The goal of this project is to develop radionuclide molecular imaging technologies using a clinical pinhole SPECT/CT scanner to quantify changes in cardiac metabolism using the spontaneously hypertensive rat (SHR) as a model of hypertensive-related pathophysiology. This paper quantitatively compares fatty acid metabolism in hearts of SHR and Wistar-Kyoto normal rats as a function of age and thereby tracks physiological changes associated with the onset and progression of heart failure in the SHR model. The fatty acid analog, 123 I-labeled BMIPP, was used in longitudinal metabolic pinhole SPECT imaging studies performed every seven months for 21 months. The uniquenessmore » of this project is the development of techniques for estimating the blood input function from projection data acquired by a slowly rotating camera that is imaging fast circulation and the quantification of the kinetics of 123 I-BMIPP by fitting compartmental models to the blood and tissue time-activity curves.« less

  1. Comparison of 4D-microSPECT and microCT for murine cardiac function

    PubMed Central

    Befera, Nicholas T.; Badea, Cristian T.; Johnson, G. Allan

    2014-01-01

    Purpose The objective of this study was to compare a new generation of four-dimensional (4D) microSPECT with microCT for quantitative in vivo assessment of murine cardiac function. Procedures 4D isotropic cardiac images were acquired from normal C57BL/6 mice with either microSPECT at 350-micron resolution (n=6) or microCT at 88-micron resolution (n=6). One additional mouse with myocardial infarction (MI) was scanned with both modalities. Prior to imaging, mice were injected with either 99mTc -tetrofosmin for microSPECT, or a liposomal blood pool contrast agent for microCT. Segmentation of the left ventricle (LV) was performed using Vitrea (Vital Images) software, to derive global and regional function. Results Measures of global LV function between microSPECT and microCT groups were comparable (e.g. ejection fraction=71±6%-microSPECT and 68±4%-microCT). Regional functional indices (wall motion, wall thickening, regional ejection fraction) were also similar for the two modalities. In the mouse with MI, microSPECT identified a large perfusion defect that was not evident with microCT. Conclusions Despite lower spatial resolution, microSPECT was comparable to microCT in the quantitative evaluation of cardiac function. MicroSPECT offers an advantage over microCT in the ability to evaluate myocardial perfusion radiotracer distribution and function simultaneously. MicroSPECT should be considered as an alternative to microCT and MR for preclinical cardiac imaging in the mouse. PMID:24037175

  2. Onboard functional and molecular imaging: A design investigation for robotic multipinhole SPECT

    SciTech Connect

    Bowsher, James Giles, William; Yin, Fang-Fang; Yan, Susu; Roper, Justin

    2014-01-15

    Purpose: Onboard imaging—currently performed primarily by x-ray transmission modalities—is essential in modern radiation therapy. As radiation therapy moves toward personalized medicine, molecular imaging, which views individual gene expression, may also be important onboard. Nuclear medicine methods, such as single photon emission computed tomography (SPECT), are premier modalities for molecular imaging. The purpose of this study is to investigate a robotic multipinhole approach to onboard SPECT. Methods: Computer-aided design (CAD) studies were performed to assess the feasibility of maneuvering a robotic SPECT system about a patient in position for radiation therapy. In order to obtain fast, high-quality SPECT images, a 49-pinhole SPECT camera was designed which provides high sensitivity to photons emitted from an imaging region of interest. This multipinhole system was investigated by computer-simulation studies. Seventeen hot spots 10 and 7 mm in diameter were placed in the breast region of a supine female phantom. Hot spot activity concentration was six times that of background. For the 49-pinhole camera and a reference, more conventional, broad field-of-view (FOV) SPECT system, projection data were computer simulated for 4-min scans and SPECT images were reconstructed. Hot-spot localization was evaluated using a nonprewhitening forced-choice numerical observer. Results: The CAD simulation studies found that robots could maneuver SPECT cameras about patients in position for radiation therapy. In the imaging studies, most hot spots were apparent in the 49-pinhole images. Average localization errors for 10-mm- and 7-mm-diameter hot spots were 0.4 and 1.7 mm, respectively, for the 49-pinhole system, and 3.1 and 5.7 mm, respectively, for the reference broad-FOV system. Conclusions: A robot could maneuver a multipinhole SPECT system about a patient in position for radiation therapy. The system could provide onboard functional and molecular imaging with 4-min

  3. Onboard functional and molecular imaging: A design investigation for robotic multipinhole SPECT

    PubMed Central

    Bowsher, James; Yan, Susu; Roper, Justin; Giles, William; Yin, Fang-Fang

    2014-01-01

    Purpose: Onboard imaging—currently performed primarily by x-ray transmission modalities—is essential in modern radiation therapy. As radiation therapy moves toward personalized medicine, molecular imaging, which views individual gene expression, may also be important onboard. Nuclear medicine methods, such as single photon emission computed tomography (SPECT), are premier modalities for molecular imaging. The purpose of this study is to investigate a robotic multipinhole approach to onboard SPECT. Methods: Computer-aided design (CAD) studies were performed to assess the feasibility of maneuvering a robotic SPECT system about a patient in position for radiation therapy. In order to obtain fast, high-quality SPECT images, a 49-pinhole SPECT camera was designed which provides high sensitivity to photons emitted from an imaging region of interest. This multipinhole system was investigated by computer-simulation studies. Seventeen hot spots 10 and 7 mm in diameter were placed in the breast region of a supine female phantom. Hot spot activity concentration was six times that of background. For the 49-pinhole camera and a reference, more conventional, broad field-of-view (FOV) SPECT system, projection data were computer simulated for 4-min scans and SPECT images were reconstructed. Hot-spot localization was evaluated using a nonprewhitening forced-choice numerical observer. Results: The CAD simulation studies found that robots could maneuver SPECT cameras about patients in position for radiation therapy. In the imaging studies, most hot spots were apparent in the 49-pinhole images. Average localization errors for 10-mm- and 7-mm-diameter hot spots were 0.4 and 1.7 mm, respectively, for the 49-pinhole system, and 3.1 and 5.7 mm, respectively, for the reference broad-FOV system. Conclusions: A robot could maneuver a multipinhole SPECT system about a patient in position for radiation therapy. The system could provide onboard functional and molecular imaging with 4-min

  4. SPECT reconstruction using DCT-induced tight framelet regularization

    NASA Astrophysics Data System (ADS)

    Zhang, Jiahan; Li, Si; Xu, Yuesheng; Schmidtlein, C. R.; Lipson, Edward D.; Feiglin, David H.; Krol, Andrzej

    2015-03-01

    Wavelet transforms have been successfully applied in many fields of image processing. Yet, to our knowledge, they have never been directly incorporated to the objective function in Emission Computed Tomography (ECT) image reconstruction. Our aim has been to investigate if the ℓ1-norm of non-decimated discrete cosine transform (DCT) coefficients of the estimated radiotracer distribution could be effectively used as the regularization term for the penalized-likelihood (PL) reconstruction, where a regularizer is used to enforce the image smoothness in the reconstruction. In this study, the ℓ1-norm of 2D DCT wavelet decomposition was used as a regularization term. The Preconditioned Alternating Projection Algorithm (PAPA), which we proposed in earlier work to solve penalized likelihood (PL) reconstruction with non-differentiable regularizers, was used to solve this optimization problem. The DCT wavelet decompositions were performed on the transaxial reconstructed images. We reconstructed Monte Carlo simulated SPECT data obtained for a numerical phantom with Gaussian blobs as hot lesions and with a warm random lumpy background. Reconstructed images using the proposed method exhibited better noise suppression and improved lesion conspicuity, compared with images reconstructed using expectation maximization (EM) algorithm with Gaussian post filter (GPF). Also, the mean square error (MSE) was smaller, compared with EM-GPF. A critical and challenging aspect of this method was selection of optimal parameters. In summary, our numerical experiments demonstrated that the ℓ1-norm of discrete cosine transform (DCT) wavelet frame transform DCT regularizer shows promise for SPECT image reconstruction using PAPA method.

  5. SPECT in Alzheimer`s disease and the dementias

    SciTech Connect

    Bonte, F.J.

    1991-12-31

    Among 90 patients with a clinical diagnosis of Alzheimer`s disease (AD), two subgroups were identified for special study, including 42 patients who had a history of dementia in one or more first-degree relatives, and 14 who had a diagnosis of early AD. Of the 42 patients with a family history of dementia, 34 out of the 35 patients whose final clinical diagnosis was possible or probable AD had positive SPECT rCBF studies. Studies in the 14 patients thought to have very early AD were positive in 11 cases. This finding suggests that altered cortical physiology, and hence, rCBF, occurs quite early in the course of AD, perhaps before the onset of symptoms. It is possible that Xenon 133 rCBF studies might be used to detect the presence of subclinical AD in a population of individuals at risk to this disorder. Despite the drawbacks of a radionuclide with poor photon energy, Xenon 133, with its low cost and round-the-clock availability, deserves further study. Although the physical characteristics of Xenon 127 might make it preferable as a SPECT tracer, it is still not regularly available, and some instrument systems are not designed to handle its higher photon energies.

  6. Brain perfusion SPECT and MRI in foetal alcohol syndrome.

    PubMed

    Riikonen, R; Salonen, I; Partanen, K; Verho, S

    1999-10-01

    Six boys and five girls with a mean age of 8.6 (range 3 to 13) years with foetal alcohol syndrome (FAS) were studied by MRI and single photon emission computed tomography (SPECT) to find specific areas of vulnerability. Morphological anomalies shown in six of 11 patients by MRI were situated both cortically and subcortically: cortical atrophy (N = 2), dilated ventricle (N = 1), corpus callosum hypoplasia (N = 1), cerebellar atrophy (N = 2), one of the latter with Arnold-Chiari malformation (N = 1). Delayed myelination of the white matter was seen in two patients. Volumetric studies of the hippocampus showed morphological left-right asymmetry in five of eight patients. However, SPECT showed mild hypoperfusion of the left hemisphere in all 10 subjects. The negative left-right index was located especially in the left parietooccipital region, i.e. in the brain areas implicated in arithmetical and logical-grammatical functions, which are known to be affected in FAS. Normal left-right dominance was also lacking in the frontal area, i.e. the brain area affected in attention-deficit-hyperactivity disorder (ADHD). Detection of these abnormalities, although they are not unique to FAS, may be helpful in the diagnosis and any attempts at rehabilitation. Diverse morphological and functional abnormalities are more frequent than has usually been believed even in less impaired children with FAS.

  7. Intrinsic Feature Pose Measurement for Awake Animal SPECT Imaging

    SciTech Connect

    Goddard Jr, James Samuel; Baba, Justin S; Lee, Seung Joon; Weisenberger, A G; Stolin, A; McKisson, J; Smith, M F

    2009-01-01

    New developments have been made in optical motion tracking for awake animal imaging that measures 3D position and orientation (pose) for a single photon emission computed tomography (SPECT) imaging system. Ongoing SPECT imaging research has been directed towards head motion measurement for brain studies in awake, unrestrained mice. In contrast to previous results using external markers, this work extracts and tracks intrinsic features from multiple camera images and computes relative pose from the tracked features over time. Motion tracking thus far has been limited to measuring extrinsic features such as retro-reflective markers applied to the mouse s head. While this approach has been proven to be accurate, the additional animal handling required to attach the markers is undesirable. A significant improvement in the procedure is achieved by measuring the pose of the head without extrinsic markers using only the external surface appearance. This approach is currently being developed with initial results presented here. The intrinsic features measurement extracts discrete, sparse natural features from 2D images such as eyes, nose, mouth and other visible structures. Stereo correspondence between features for a camera pair is determined for calculation of 3D positions. These features are also tracked over time to provide continuity for surface model fitting. Experimental results from live images are presented.

  8. First measurements with the neutron decay spectrometer a SPECT

    NASA Astrophysics Data System (ADS)

    Baeßler, S.; Ayala Guardia, F.; Borg, M.; Glück, F.; Heil, W.; Konrad, G.; Konorov, I.; Muñoz Horta, R.; Petzoldt, G.; Rich, D.; Simson, M.; Sobolev, Yu.; Wirth, H.-F.; Zimmer, O.

    2008-10-01

    The neutron decay spectrometer a SPECT has been built to perform a precise measurement of the proton spectrum shape in the decay of free neutrons. Such a measurement allows a determination of the neutrino electron angular-correlation coefficient a . The present best experiments have an uncertainty of Δ a/ a = 5% and since the seventies there is no substantial improvement. With a SPECT, we aim for an uncertainty which is lower by more than an order of magnitude, thus enabling us to perform several precise tests of the Standard Model. In our first beam time at the particle physics beam MEPHISTO at the Forschungsneutronenquelle Heinz Maier-Leibnitz, we studied the properties of the spectrometer. The most serious problem turned out to be the situation- and time-dependent behavior of the background. From the data sets from this beam time in which a background problem was not obvious, we could extract a value of a = - 0.1151±0.0040stat , but we could not quantify the background uncertainty. We show ways to deal with the background and other problems for future beam times.

  9. New SPECT and PET Radiopharmaceuticals for Imaging Cardiovascular Disease

    PubMed Central

    Sogbein, Oyebola O.; Pelletier-Galarneau, Matthieu; Schindler, Thomas H.; Wei, Lihui; Wells, R. Glenn; Ruddy, Terrence D.

    2014-01-01

    Nuclear cardiology has experienced exponential growth within the past four decades with converging capacity to diagnose and influence management of a variety of cardiovascular diseases. Single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) with technetium-99m radiotracers or thallium-201 has dominated the field; however new hardware and software designs that optimize image quality with reduced radiation exposure are fuelling a resurgence of interest at the preclinical and clinical levels to expand beyond MPI. Other imaging modalities including positron emission tomography (PET) and magnetic resonance imaging (MRI) continue to emerge as powerful players with an expanded capacity to diagnose a variety of cardiac conditions. At the forefront of this resurgence is the development of novel target vectors based on an enhanced understanding of the underlying pathophysiological process in the subcellular domain. Molecular imaging with novel radiopharmaceuticals engineered to target a specific subcellular process has the capacity to improve diagnostic accuracy and deliver enhanced prognostic information to alter management. This paper, while not comprehensive, will review the recent advancements in radiotracer development for SPECT and PET MPI, autonomic dysfunction, apoptosis, atherosclerotic plaques, metabolism, and viability. The relevant radiochemistry and preclinical and clinical development in addition to molecular imaging with emerging modalities such as cardiac MRI and PET-MR will be discussed. PMID:24901002

  10. Simultaneous CT and SPECT tomography using CZT detectors

    DOEpatents

    Paulus, Michael J.; Sari-Sarraf, Hamed; Simpson, Michael L.; Britton, Jr., Charles L.

    2002-01-01

    A method for simultaneous transmission x-ray computed tomography (CT) and single photon emission tomography (SPECT) comprises the steps of: injecting a subject with a tracer compound tagged with a .gamma.-ray emitting nuclide; directing an x-ray source toward the subject; rotating the x-ray source around the subject; emitting x-rays during the rotating step; rotating a cadmium zinc telluride (CZT) two-sided detector on an opposite side of the subject from the source; simultaneously detecting the position and energy of each pulsed x-ray and each emitted .gamma.-ray captured by the CZT detector; recording data for each position and each energy of each the captured x-ray and .gamma.-ray; and, creating CT and SPECT images from the recorded data. The transmitted energy levels of the x-rays lower are biased lower than energy levels of the .gamma.-rays. The x-ray source is operated in a continuous mode. The method can be implemented at ambient temperatures.

  11. Unusual Adrenal and Brain Metastases From Follicular Thyroid Carcinoma Revealed by 131I SPECT/CT.

    PubMed

    Zhao, Zhen; Shen, Guo-hua; Liu, Bin; Kuang, An-ren

    2016-01-01

    The adrenal metastasis from differentiated thyroid carcinoma is uncommon. Metastatic involvement of both adrenal and brain in the same patient from differentiated thyroid carcinoma is rare. Here, we described an unusual case with iodine-avid lung, bone, adrenal, liver, and brain metastases from follicular thyroid carcinoma confirmed by 131I SPECT/CT. The utilization of SPECT/CT in thyroid cancer patients can detect the presence of metastases and also exclude potential false-positive lesions. Our case demonstrates that SPECT/CT is helpful in localizing and confirming metastatic lesions from differentiated thyroid carcinoma in rare and unusual sites.

  12. An automated voxelized dosimetry tool for radionuclide therapy based on serial quantitative SPECT/CT imaging

    SciTech Connect

    Jackson, Price A.; Kron, Tomas; Beauregard, Jean-Mathieu; Hofman, Michael S.; Hogg, Annette; Hicks, Rodney J.

    2013-11-15

    Purpose: To create an accurate map of the distribution of radiation dose deposition in healthy and target tissues during radionuclide therapy.Methods: Serial quantitative SPECT/CT images were acquired at 4, 24, and 72 h for 28 {sup 177}Lu-octreotate peptide receptor radionuclide therapy (PRRT) administrations in 17 patients with advanced neuroendocrine tumors. Deformable image registration was combined with an in-house programming algorithm to interpolate pharmacokinetic uptake and clearance at a voxel level. The resultant cumulated activity image series are comprised of values representing the total number of decays within each voxel's volume. For PRRT, cumulated activity was translated to absorbed dose based on Monte Carlo-determined voxel S-values at a combination of long and short ranges. These dosimetric image sets were compared for mean radiation absorbed dose to at-risk organs using a conventional MIRD protocol (OLINDA 1.1).Results: Absorbed dose values to solid organs (liver, kidneys, and spleen) were within 10% using both techniques. Dose estimates to marrow were greater using the voxelized protocol, attributed to the software incorporating crossfire effect from nearby tumor volumes.Conclusions: The technique presented offers an efficient, automated tool for PRRT dosimetry based on serial post-therapy imaging. Following retrospective analysis, this method of high-resolution dosimetry may allow physicians to prescribe activity based on required dose to tumor volume or radiation limits to healthy tissue in individual patients.

  13. SPECT imaging in evaluating extent of malignant external otitis: case report

    SciTech Connect

    English, R.J.; Tu'Meh, S.S.; Piwnica-Worms, D.; Holman, B.L.

    1987-03-01

    Otitis externa, a benign inflammatory process of the external auditory canal, is general responsive to local therapy. Some patients however, develop a less controllable disease leading to chondritis and osteomyelitis of the base of the skull. The direct invasive characteristic of the disease has led to the descriptive term malignant external otitis (MEO), more appropriately called necrotizing or invasive external otitis. Malignant external otitis is caused by an aggressive pseudomonas or proteus infection that almost exclusively occurs in elderly diabetic patients. The primary imaging modalities previously used in the diagnosis and evaluation of MEO were standard planar scintigraphic techniques with technetium-99M (/sup 99m/Tc) bone agents and gallium-67 (/sup 67/Ga), and pluridirectional tomography. The advent of high resolution computed tomography (CT) effectively allowed demonstration of the soft tissue extension and bone destruction associated with MEO, but still suffered from the low sensitivity constraints of all radiographic techniques in determining early inflammatory bone involvement. Recent work suggests that scintigraphic detection of MEO with /sup 99m/Tc-MDP and /sup 67/Ga, combined with the cross-sectional resolution of single photon emission computed tomography (SPECT) may be of value in planning treatment of this inflammatory condition.

  14. Respiratory Motion Detection and Correction in ECG-Gated SPECT: a New Approach

    PubMed Central

    Bitarafan, Ahmad; Rajabi, Hossein; Gruy, Bernhard; Rustgou, Feridoon; Sharafi, Ali Akbar; Firoozabady, Hasan; Yaghoobi, Nahid; Malek, Hadi; Pirich, Christian; Langesteger, Werner

    2008-01-01

    Objective Gated myocardial perfusion single-photon emission computed tomography (GSPECT) has been established as an accurate and reproducible diagnostic and prognostic technique for the assessment of myocardial perfusion and function. Respiratory motion is among the major factors that may affect the quality of myocardial perfusion imaging (MPI) and consequently the accuracy of the examination. In this study, we have proposed a new approach for the tracking of respiratory motion and the correction of unwanted respiratory motion by the use of respiratory-cardiac gated-SPECT (RC-GSPECT). In addition, we have evaluated the use of RC-GSPECT for quantitative and visual assessment of myocardial perfusion and function. Materials and Methods Twenty-six patients with known or suspected coronary artery disease (CAD)-underwent two-day stress and rest 99mTc-Tetrofosmin myocardial scintigraphy using both conventional GSPECT and RC-GSPECT methods. The respiratory signals were induced by use of a CT real-time position management (RPM) respiratory gating interface. A PIO-D144 card, which is transistor-transistor logic (TTL) compatible, was used as the input interface for simultaneous detection of both ECG and respiration signals. Results A total of 26 patients with known or suspected CAD were examined in this study. Stress and rest myocardial respiratory motion in the vertical direction was 8.8-16.6 mm (mean, 12.4 ± 2.9 mm) and 7.8-11.8 mm (mean, 9.5 ± 1.6 mm), respectively. The percentages of tracer intensity in the inferior, inferoseptal and septal walls as well as the inferior to lateral (I/L) uptake ratio was significantly higher with the use of RC-GSPECT as compared to the use of GSPECT (p < 0.01). In a left ventricular ejection fraction (LVEF) correlation analysis between the use of rest GSPECT and RC-GSPECT with echocardiography, better correlation was noted between RC-GSPECT and echocardiography as compared with the use of GSPECT (y = 0.9654x + 1.6514; r = 0.93, p < 0

  15. SPECT imaging evaluation in movement disorders: far beyond visual assessment.

    PubMed

    Badiavas, Kosmas; Molyvda, Elisavet; Iakovou, Ioannis; Tsolaki, Magdalini; Psarrakos, Kyriakos; Karatzas, Nikolaos

    2011-04-01

    Single photon emission computed tomography (SPECT) imaging with (123)I-FP-CIT is of great value in differentiating patients suffering from Parkinson's disease (PD) from those suffering from essential tremor (ET). Moreover, SPECT with (123)I-IBZM can differentiate PD from Parkinson's "plus" syndromes. Diagnosis is still mainly based on experienced observers' visual assessment of the resulting images while many quantitative methods have been developed in order to assist diagnosis since the early days of neuroimaging. The aim of this work is to attempt to categorize, briefly present and comment on a number of semi-quantification methods used in nuclear medicine neuroimaging. Various arithmetic indices have been introduced with region of interest (ROI) manual drawing methods giving their place to automated procedures, while advancing computer technology has allowed automated image registration, fusion and segmentation to bring quantification closer to the final diagnosis based on the whole of the patient's examinations results, clinical condition and response to therapy. The search for absolute quantification has passed through neuroreceptor quantification models, which are invasive methods that involve tracer kinetic modelling and arterial blood sampling, a practice that is not commonly used in a clinical environment. On the other hand, semi-quantification methods relying on computers and dedicated software try to elicit numerical information out of SPECT images. The application of semi-quantification methods aims at separating the different patient categories solving the main problem of finding the uptake in the structures of interest. The semi-quantification methods which were studied fall roughly into three categories, which are described as classic methods, advanced automated methods and pixel-based statistical analysis methods. All these methods can be further divided into various subcategories. The plethora of the existing semi-quantitative methods reinforces

  16. Stability of [123I]IBZM SPECT measurement of amphetamine-induced striatal dopamine release in humans.

    PubMed

    Kegeles, L S; Zea-Ponce, Y; Abi-Dargham, A; Rodenhiser, J; Wang, T; Weiss, R; Van Heertum, R L; Mann, J J; Laruelle, M

    1999-03-15

    Binding competition between endogenous dopamine (DA) and the D2 receptor radiotracer [123I]IBZM allows measurement of the change in synaptic DA following amphetamine challenge with SPECT in the living human brain. Previous investigations using this technique in healthy subjects have shown that the magnitude of amphetamine effect on [123I]IBZM binding potential (BP) is small (range between 5 to 15% decrease), and that a large between-subject variability in this effect is observed. Therefore, it was unclear how much of the apparent between-subject variability was due to a low signal-to-noise ratio in the measurement, vs. true between-subject differences in the magnitude of the response. The goals of this investigation were to test the within-subject reproducibility and reliability of amphetamine-induced decrease in [123I]IBZM BP with a test/retest paradigm, and to establish the presence or absence of tolerance or sensitization to single administration ofi.v. amphetamine. Six healthy male subjects, never previously exposed to psychostimulants, twice underwent measurement of striatal amphetamine-induced DA release (between-measurement interval 16 +/- 10 days) using SPECT and the [123I]IBZM constant infusion technique. Results demonstrated an excellent within-subject reproducibility of amphetamine-induced DA release: amphetamine-induced decreases in [123I]IBZM BP were significant on each day, and had an intraclass correlation coefficient (ICC) of 0.89. Moreover, values from the second experiment were not significantly different from first experiment, suggesting the absence of either sensitization or tolerance to the effect of amphetamine on DA release in these experimental conditions. The subjective activation, as rated by the subjects on analog scales, was also highly reproducible. In conclusion, this scanning technique provides a reliable measurement of amphetamine-induced reduction of [123I]IBZM BP and enables detection of between-subject differences that appear

  17. [Effect of wall thickness of left ventricle on 201Tl myocardial SPECT images: myocardial phantom study].

    PubMed

    Koto, M; Namura, H; Kawase, O; Yamasaki, K; Kono, M

    1996-07-01

    201Tl myocardial SPECT is known for better sensitivity, specificity, and accuracy than planar images in detecting coronary artery disease and diagnosing myocardial viability. SPECT images are also superior to planar images in diagnostic sensitivity and anatomical orientation. However, as limitation of the spatial resolution of the machine, we often encounter poor SPECT plower image quality in patients with decreased wall thickness. To test the accuracy of SPECT images in patients with marked thinning of the left ventricular wall, as occurs in dilated cardiomyopathy, we performed a experimental study using myocardial phantom with 7 mm wall thickness. Tomographic image of the phantom images were rather heterogeneous, though no artificial defect was located. Dilated cardiomyopathy is thought to be characterized by patchy defects in the left ventricle. Careful attention should be given to elucidating myocardial perfusion in patients with a thin left ventricle wall, as there are technical limitations in addition to clinical features.

  18. Clinical application of SPECT in adrenal imaging with iodine-131 6 beta-iodomethyl-19-norcholesterol

    SciTech Connect

    Ishimura, J.; Kawanaka, M.; Fukuchi, M.

    1989-04-01

    Forty-one patients with or without adrenocortical disorders were studied to evaluate the clinical usefulness of SPECT in adrenal imaging with I-131 Adosterol. In the SPECT images from this study, all glands with either normally functioning or hyperfunctioning adrenal cortices could be detected, while those glands with hypofunctioning adrenal cortices could not be detected. Particularly in transaxial and sagittal slices, the adrenal gland was identified posteriorly and was clearly distinguished from the gallbladder. In preliminary results using SPECT by a standard method, uptake in 68 detectable glands ranged from 1.7% to 4.9% in four glands with Cushing's syndrome, from 1.1% to 1.3% in seven glands with primary aldosteronism, and were distributed below 1.0% in the remaining glands with normally functioning adrenal cortices. These data show that it is possible to evaluate the adrenocortical functioning status simply by analyzing the SPECT images of the adrenal.

  19. SPECT assay of radiolabeled monoclonal antibodies. Comprehensive progress report, September 1989--February 1992

    SciTech Connect

    Jaszczak, R.J.

    1992-02-01

    The long-term goal of this research project is to develop methods to improve the utility of single photon emission computed tomography (SPECI) to quantify the biodistribution of monoclonal antibodies (MoAbs) labeled with clinically relevant radionuclides ({sup 123}I, {sup 131}I, and {sup 111}In) and with another radionuclide,{sup 211}At, recently used in therapy. We describe here our progress in developing quantitative SPECT methodology for {sup 111}In and {sup 123}I. We have focused our recent research thrusts on the following aspects of SPECT: (1) The development of improved SPECT hardware, such as improved acquisition geometries. (2) The development of better reconstruction methods that provide accurate compensation for the physical factors that affect SPECT quantification. (3) The application of carefully designed simulations and experiments to validate our hardware and software approaches.

  20. A SPECT study in internal carotid artery occlusion: Discrepancies between flow image and neurologic deficits

    SciTech Connect

    Moriwaki, H.; Hougaku, H.; Matsuda, I.; Kusunoki, M.; Shirai, J. )

    1989-08-01

    A SPECT (single photon emission computed tomography) study in internal carotid artery (ICA) occlusion was performed in 6 patients. The validity of iodoamphetamine (IMP) SPECT study in the evaluation of cerebral blood flow (CBF) or neurologic function is still controversial. In this study, the authors showed several cases in whom SPECT images of brain were not compatible with their neurologic deficits. In 2 typical cases, a large low-density area was observed in the non-dominant hemisphere in computed tomography (CT) scan, but no apparent motor-sensory deficits in left limbs were present. In these patients, SPECT study also revealed flow reduction in the affected side of the brain. So there was a possibility that an IMP brain image could not always reflect CBF, which maintains neurologic function of the brain.

  1. Photon count and contrast-detail detection potential comparison between parallel and fan beam brain SPECT

    SciTech Connect

    Kim, K.I.; Lim, C.B.

    1986-02-01

    Current brain SPECT based on parallel beam projection with round shape Anger cameras suffers from both low sensitivity and poor resolution due to shoulder interference. SPECT using fan beam projection with a wide rectangular camera would significantly improve image quality by increased sensitivity and close brain access. For experimental verification a rectangular camera of 16'' x 8.7'' FOV has been developed with a shoulder edge of 3''. For this geometry sensitivity and resolution improvement have been measured. Fan beam imaging tests verified the analysis results by showing 60% sensitivity increase and resolution improvement to 10 mm from 13-14 mm at image center. In order to assess the imaging improvement level quantitatively, analytical comparison on SPECT contrast-detail detectability has been made. Experimental contrast-detail detectability comparison between parallel and fan beam brain SPECT is presented together with the predicted model result.

  2. [Neurological diseases and SPECT--analysis using easy Z-score imaging system (eZIS)].

    PubMed

    Matsuda, Hiroshi

    2007-05-01

    We developed a method for automated diagnosis of brain perfusion SPECT and designated this method as an easy Z-score imaging system (eZIS). In this software program, voxel-by-voxel Z-score analysis after voxel normalization to global mean or cerebellar values; Z-score = ( [control mean] - [individual value] )/ (control SD) is performed. These Z-score maps are displayed by overlay on tomographic sections and by projection with averaged Z-score of 14mm thickness to surface rendering of the anatomically standardized MRI template. Anatomical standardization of SPECT images into a stereotactic space is performed using statistical parametric mapping (SPM) 2. This program has an advantage of capability of incorporation of SPM results into automated analysis of Z-score values as a volume of interest (VOI). A specific VOI can be determined by group comparison of SPECT images for patients with a neuropsychiatric disease with those for healthy volunteers using SPM. Even if a center can construct a normal database with good quality comprising a large number of healthy volunteers, other centers have not been able to use this normal database because of differences between the used gamma cameras, collimators and physical correction algorithms. Since SPECT exhibits greater variations in image quality among different centers than PET, conversion of SPECT images may be necessary for sharing a normal database. In this eZIS software, we incorporated a newly developed program for making it possible to share a normal database in SPECT studies. A Hoffman 3-dimensional brain phantom experiment was conducted to determine systematic differences between SPECT scanners. SPECT images for the brain phantom were obtained using two different scanners. Dividing these two phantom images after anatomical standardization by SPM created a 3-dimensional conversion map. The use of a conversion map obtained from SPECT images of the same phantom provided very similar SPECT data despite extreme differences

  3. Cardiac sarcoidosis demonstrated by Tl-201 and Ga-67 SPECT imaging

    SciTech Connect

    Taki, J.; Nakajima, K.; Bunko, H.; Ohguchi, M.; Tonami, N.; Hisada, K. )

    1990-09-01

    Ga-67 and Tl-201 SPECT was performed to evaluate cardiac sarcoidosis in a 15-year-old boy. Tl-201 SPECT imaging showed decreased uptake in the inferior to lateral wall and Ga-67 accumulation in the area of decreased Tl-201 uptake. These findings suggested cardiac sarcoidosis, and cardiac biopsy confirmed this diagnosis. After corticosteroid therapy, myocardial uptake of Ga-67 disappeared and myocardial TI-201 uptake became more homogeneous.

  4. Thallium-201-chloride and technetium-99m-MIBI SPECT of primary and metastatic lung carcinoma.

    PubMed

    Kashitani, N; Makihara, S; Maeda, T; Eda, R; Takeyama, H; Hiraki, Y

    1999-01-01

    We compared technetium-99m-MIBI (Tc-99m MIBI) with thallium-201-chloride (Tl-201) SPECT imaging in patients with lung carcinoma. In addition, we compared the imaging characteristics of Tl-201 and Tc-99m MIBI after radiation therapy. Thirty-seven patients with primary lung carcinoma were evaluated with SPECT imaging for metastasis to the mediastinal lymph nodes and brain. Patients were imaged with Tl-201 chloride images 10 and 180 min after injection. Patients were also imaged 10 min after injection of Tc-99m MIBI. The sensitivity of Tl-201 SPECT for the primary lesion and brain metastasis was 97.1% and 70.0% respectively at 10 min and 97.1% and 60.0% at 180 min. The sensitivity of Tc-99m MIBI SPECT was 97.1% (for the identification of the primary lesion) and 50.0% (for the detection of brain metastasis) at 10 min. The uptake ratios (count in tumor/count in normal lung or brain) at 10 min on the Tl-201 SPECT and on the Tc-99m MIBI SPECT were not significantly different for the primary tumor or for brain metastasis. The uptake ratios were better for Tc-99m MIBI than for Tl-201 [2.82 vs. 1.99 (p<0.05)] for mediastinal lymph nodes. Decreasing uptake ratios and retention index with both agents after radiation therapy are concordant to the follow-up clinical course. Tc-99m MIBI SPECT is more sensitive in the detection of metastasis to mediastinal lymph nodes than Tl-201 SPECT.

  5. U-SPECT-BioFluo: an integrated radionuclide, bioluminescence, and fluorescence imaging platform

    PubMed Central

    2014-01-01

    Background In vivo bioluminescence, fluorescence, and single-photon emission computed tomography (SPECT) imaging provide complementary information about biological processes. However, to date these signatures are evaluated separately on individual preclinical systems. In this paper, we introduce a fully integrated bioluminescence-fluorescence-SPECT platform. Next to an optimization in logistics and image fusion, this integration can help improve understanding of the optical imaging (OI) results. Methods An OI module was developed for a preclinical SPECT system (U-SPECT, MILabs, Utrecht, the Netherlands). The applicability of the module for bioluminescence and fluorescence imaging was evaluated in both a phantom and in an in vivo setting using mice implanted with a 4 T1-luc + tumor. A combination of a fluorescent dye and radioactive moiety was used to directly relate the optical images of the module to the SPECT findings. Bioluminescence imaging (BLI) was compared to the localization of the fluorescence signal in the tumors. Results Both the phantom and in vivo mouse studies showed that superficial fluorescence signals could be imaged accurately. The SPECT and bioluminescence images could be used to place the fluorescence findings in perspective, e.g. by showing tracer accumulation in non-target organs such as the liver and kidneys (SPECT) and giving a semi-quantitative read-out for tumor spread (bioluminescence). Conclusions We developed a fully integrated multimodal platform that provides complementary registered imaging of bioluminescent, fluorescent, and SPECT signatures in a single scanning session with a single dose of anesthesia. In our view, integration of these modalities helps to improve data interpretation of optical findings in relation to radionuclide images. PMID:25386389

  6. A direct measurement of skull attenuation for quantitative SPECT

    SciTech Connect

    Turkington, T.G.; Gilland, D.R.; Jaszczak, R.J.; Greer, K.L.; Coleman, R.E. . Dept. of Radiology); Smith, M.F. . Dept. of Biomedical Engineering)

    1993-08-01

    The attenuation of 140 keV photons was measured in three empty skulls by placing a [sup 99m]Tc line source inside each one and acquiring projection data. These projections were compared to projections of the line source alone to determine the transmission through each point in the skull surrounding the line source. The effective skull thickness was calculated for each point using an assumed dense bone attenuation coefficient. The relative attenuation for this thickness of bone was compared to that of an equivalent amount of soft tissue to evaluate the increased attenuation of photons in brain SPECT relative to a uniform soft tissue approximation. For the skull regions surrounding most of the brain, the effective bone thickness varied considerably, but was generally less than 6 mm, resulting in a relative attenuation increases of less than 6%.

  7. PET/SPECT imaging agents for neurodegenerative diseases

    PubMed Central

    Zhu, Lin; Ploessl, Karl; Kung, Hank F.

    2014-01-01

    Single photon emission computed tomography (SPECT) or positron emission computed tomography (PET) imaging agents for neurodegenerative disease have a significant impact on clinical diagnosis and patient care. The examples of Parkinson’s Disease (PD) and Alzheimer’s Disease (AD) imaging agents described in this paper provide a general view on how imaging agents, ie radioactive drugs, are selected, chemically prepared and applied in humans. Imaging the living human brain can provide unique information on the pathology and progression of neurodegenerative diseases, such as AD and PD. The imaging method will also facilitate preclinical and clinical trials of new drugs offering specific information related to drug binding sites in the brain. In the future, chemists will continue to play important roles in identifying specific targets, synthesizing target-specific probes for screening and ultimately testing them by in vitro and in vivo assays. PMID:24676152

  8. Attenuation compensation in mesh-domain OSEM SPECT reconstruction

    NASA Astrophysics Data System (ADS)

    Vogelsang, Levon; Lu, Yao; Yu, Bo; Krol, Andrzej; Xu, Yuesheng; Hu, Xiaofei; Feiglin, David; Lipson, Edward

    2009-02-01

    A new method for attenuation compensation (AC) in mesh-domain SPECT OSEM reconstruction using strip-area approximation (SAAC) is introduced and compared to single-ray AC (SRAC). SAAC uses the polygonal area of the intersection of a mesh element (ME) and a tube-of-response (TOR) for defining an effective length of photon transit and an effective attenuation coefficient. This approach to AC is compared to SRAC, which defines the effective length of photon transit as the intersection of a single ray and a ME and the effective attenuation coefficient as the mean along the ray path. Comparative quantitative and qualitative analysis demonstrated that SAAC outperformed SRAC in terms of reconstruction image accuracy and quality.

  9. Tomographic mesh generation for OSEM reconstruction of SPECT images

    NASA Astrophysics Data System (ADS)

    Lu, Yao; Yu, Bo; Vogelsang, Levon; Krol, Andrzej; Xu, Yuesheng; Hu, Xiaofei; Feiglin, David

    2009-02-01

    To improve quality of OSEM SPECT reconstruction in the mesh domain, we implemented an adaptive mesh generation method that produces tomographic mesh consisting of triangular elements with size and density commensurate with geometric detail of the objects. Node density and element size change smoothly as a function of distance from the edges and edge curvature without creation of 'bad' elements. Tomographic performance of mesh-based OSEM reconstruction is controlled by the tomographic mesh structure, i.e. node density distribution, which in turn is ruled by the number of key points on the boundaries. A greedy algorithm is used to influence the distribution of nodes on the boundaries. The relationship between tomographic mesh properties and OSEM reconstruction quality has been investigated. We conclude that by selecting adequate number of key points, one can produce a tomographic mesh with lowest number of nodes that is sufficient to provide desired quality of reconstructed images, appropriate for the imaging system properties.

  10. Final Report: A CdZnTe detector for MRI-compatible SPECT Systems

    SciTech Connect

    Meng, Ling-Jian

    2012-12-27

    The key objective of this project is to develop the enabling technology for future MRI-compatible nuclear (e.g. SPECT) imaging system, and to demonstrate the feasibility of performing simultaneous MR and SPECT imaging studies of the same object. During the past three years, we have developed (a) a MRI-compatible ultrahigh resolution gamma ray detector and associated readout electronics, (b) a theoretical approach for modeling the effect of strong magnetic field on SPECT image quality, and (c) a maximum-likelihood (ML) based reconstruction routine with correction for the MR-induced distortion. With this support, we have also constructed a four-head MR-compatible SPECT system and tested the system inside a 3-T clinical MR-scanner located on UI campus. The experimental results obtained with this system have clearly demonstrated that sub-500um spatial resolution can be achieved with a SPECT system operated inside a 3-T MRI scanner. During the past three years, we have accomplished most of the major objectives outlined in the original proposal. These research efforts have laid out a solid foundation the development of future MR-compatible SPECT systems for both pre-clinical and clinical imaging applications.

  11. Proceedings of the cardiac PET summit meeting 12 may 2014: Cardiac PET and SPECT instrumentation.

    PubMed

    Garcia, Ernest V

    2015-06-01

    Advances in PET and SPECT and imaging hardware and software are vastly improving the noninvasive evaluation of myocardial perfusion and function. PET perfusion imaging has benefitted from the introduction of novel detectors that now allow true 3D imaging, and precise attenuation correction (AC). These developments have also resulted in perfusion images with higher spatial and contrast resolution that may be acquired in shorter protocols and/or with less patient radiation exposure than traditional PET or SPECT studies. Hybrid PET/CT cameras utilize transmission computed tomographic (CT) scans for AC, and offer the additional clinical advantages of evaluating coronary calcium and myocardial anatomy but at a higher cost than PET scanners that use (68)Ge radioactive line sources. As cardiac PET systems continue to improve, dedicated cardiac SPECT systems are also undergoing a profound change in their design. The scintillation camera general purpose design is being replaced with systems with multiple detectors focused on the heart yielding 5 to 10 times the sensitivity of conventional SPECT. As a result, shorter acquisition times and/or lower tracer doses produce higher quality SPECT images than were possible before. This article reviews these concepts and compares the attributes of PET and SPECT instrumentation. PMID:25824018

  12. Proceedings of the cardiac PET summit meeting 12 may 2014: Cardiac PET and SPECT instrumentation.

    PubMed

    Garcia, Ernest V

    2015-06-01

    Advances in PET and SPECT and imaging hardware and software are vastly improving the noninvasive evaluation of myocardial perfusion and function. PET perfusion imaging has benefitted from the introduction of novel detectors that now allow true 3D imaging, and precise attenuation correction (AC). These developments have also resulted in perfusion images with higher spatial and contrast resolution that may be acquired in shorter protocols and/or with less patient radiation exposure than traditional PET or SPECT studies. Hybrid PET/CT cameras utilize transmission computed tomographic (CT) scans for AC, and offer the additional clinical advantages of evaluating coronary calcium and myocardial anatomy but at a higher cost than PET scanners that use (68)Ge radioactive line sources. As cardiac PET systems continue to improve, dedicated cardiac SPECT systems are also undergoing a profound change in their design. The scintillation camera general purpose design is being replaced with systems with multiple detectors focused on the heart yielding 5 to 10 times the sensitivity of conventional SPECT. As a result, shorter acquisition times and/or lower tracer doses produce higher quality SPECT images than were possible before. This article reviews these concepts and compares the attributes of PET and SPECT instrumentation.

  13. SPECT assay of radiolabeled monoclonal antibodies. Third yearly progress report, September 1991--February 1992

    SciTech Connect

    Jaszczak, R.J.

    1992-02-01

    The accurate determination of the biodistribution of radiolabeled monoclonal antibodies (MoAbs) is important for calculation of dosimetry and evaluation of pharmacokinetic variables such as antibody dose and route of administration. The hypothesis of this application is that the biodistribution of radiolabeled monoclonal antibodies (MoAbs) can be quantitatively determined using single photon emission computed tomography (SPECT). The major thrusts during the third year include the continued development and evaluation of improved 3D SPECT acquisition and reconstruction approaches to improve quantitative imaging of radiolabeled monoclonal antibodies (MoAbs), and the implementation and evaluation of algorithms to register serial SPECT image data sets, or to register 3D SPECT images with 3D image data sets acquired from positron emission tomography (PEI) and magnetic resonance images (MRI). The research has involved the investigation of statistical models and iterative reconstruction algorithms that accurately account for the physical characteristics of the SPECT acquisition system. It is our belief that SPECT quantification can be improved by accurately modeling the physical processes such as attenuation, scatter, geometric collimator response, and other factors that affect the measured projection data.

  14. Variable Activation of the DNA Damage Response Pathways in Patients Undergoing SPECT Myocardial Perfusion Imaging

    PubMed Central

    Hu, Shijun; Liang, Grace; Ong, Sang-Ging; Han, Leng; Sanchez-Freire, Veronica; Lee, Andrew S.; Vasanawala, Minal; Segall, George; Wu, Joseph C.

    2015-01-01

    Background Although single photon emission computed tomography myocardial perfusion imaging (SPECT MPI) has improved the diagnosis and risk stratification of patients with suspected coronary artery disease, it remains a primary source of low dose radiation exposure for cardiac patients. To determine the biological effects of low dose radiation from SPECT MPI, we measured the activation of the DNA damage response pathways using quantitative flow cytometry and single cell gene expression profiling. Methods and Results Blood samples were collected from patients before and after SPECT MPI (n=63). Overall, analysis of all recruited patients showed no marked differences in the phosphorylation of proteins (H2AX, p53, and ATM) following SPECT. The majority of patients also had either down-regulated or unchanged expression in DNA damage response genes at both 24 and 48 hours post-SPECT. Interestingly, a small subset of patients with increased phosphorylation also had significant up-regulation of genes associated with DNA damage, whereas those with no changes in phosphorylation had significant down-regulation or no difference, suggesting that some patients may potentially be more sensitive to low dose radiation exposure. Conclusions Our findings showed that SPECT MPI resulted in a variable activation of the DNA damage response pathways. Although only a small subset of patients had increased protein phosphorylation and elevated gene expression post-imaging, continued care should be taken to reduce radiation exposure to both patients and operators. PMID:25609688

  15. Down Syndrome = Sindrome de Down.

    ERIC Educational Resources Information Center

    Pueschel, S. M.; Glasgow, R. E.

    Presented both in English and Spanish, the brochure is primarily concerned with biological and developmental characteristics of the person with Down's syndrome. An emphasis is on the valuable humanizing influence these individuals have on society. Brief sections in the document discuss the delayed developmental aspects of Down's syndrome; the…

  16. Multipinhole SPECT helical scan parameters and imaging volume

    SciTech Connect

    Yao, Rutao Deng, Xiao; Wei, Qingyang; Dai, Tiantian; Ma, Tianyu; Lecomte, Roger

    2015-11-15

    Purpose: The authors developed SPECT imaging capability on an animal PET scanner using a multiple-pinhole collimator and step-and-shoot helical data acquisition protocols. The objective of this work was to determine the preferred helical scan parameters, i.e., the angular and axial step sizes, and the imaging volume, that provide optimal imaging performance. Methods: The authors studied nine helical scan protocols formed by permuting three rotational and three axial step sizes. These step sizes were chosen around the reference values analytically calculated from the estimated spatial resolution of the SPECT system and the Nyquist sampling theorem. The nine helical protocols were evaluated by two figures-of-merit: the sampling completeness percentage (SCP) and the root-mean-square (RMS) resolution. SCP was an analytically calculated numerical index based on projection sampling. RMS resolution was derived from the reconstructed images of a sphere-grid phantom. Results: The RMS resolution results show that (1) the start and end pinhole planes of the helical scheme determine the axial extent of the effective field of view (EFOV), and (2) the diameter of the transverse EFOV is adequately calculated from the geometry of the pinhole opening, since the peripheral region beyond EFOV would introduce projection multiplexing and consequent effects. The RMS resolution results of the nine helical scan schemes show optimal resolution is achieved when the axial step size is the half, and the angular step size is about twice the corresponding values derived from the Nyquist theorem. The SCP results agree in general with that of RMS resolution but are less critical in assessing the effects of helical parameters and EFOV. Conclusions: The authors quantitatively validated the effective FOV of multiple pinhole helical scan protocols and proposed a simple method to calculate optimal helical scan parameters.

  17. Regional Cerebral Blood Flow Analysis in Patients with Multiple Sclerosis Using TC-99M Hmpao and a Three - Spect System.

    NASA Astrophysics Data System (ADS)

    D'Souza, Maximian Felix

    1995-01-01

    The purpose of the present study was to determine the changes in regional cerebral blood flow (rCBF) with a cognitive task of semantic word retrieval (verbal fluency) in patients with multiple sclerosis (MS) and compare with the rCBF distribution of normal controls. Two groups of patients with low and high verbal fluency scores and two groups of normal controls were selected to determine a relationship between rCBF and verbal performance. A three-detector gamma camera (TRIAD 88) was used with radiotracer Tc-99m HMPAO and single photon emission computed tomography (SPECT) to obtain 3D rCBF maps. The performance characteristics of the camera was comprehensively studied before being utilized for clinical studies. In addition, technical improvements were implemented in the form of scatter correction and MRI-SPECT coregistration to potentially enhance the quantitative accuracy of the rCBF data. The performance analysis of the gamma camera showed remarkable consistency among the three-detector heads and yielded results that were consistent with the manufacturer's specification. Measurements of physical objects also showed excellent image quality. The coregistration of SPECT and MRI images allowed more accurate anatomical localization for extraction of regional blood flow information. The validation of the scatter correction technique with physical phantoms indicated marked improvements in quantitative accuracy. There was marked difference in activation patterns between patients and normals. In normals, individually subjects showed either an increase or a decrease in blood flow to left frontal and temporal, however, on average, there was not a statistically significant change. The lack of significant change may suggest large variability among subjects chosen or that the individual changes are not large enough to be significant. The results from MS patients showed several left cortical areas with statistically significant change in blood flow after cognitive activation

  18. Effect of reconstruction algorithms on the accuracy of (99m)Tc sestamibi SPECT/CT parathyroid imaging.

    PubMed

    Nichols, Kenneth J; Tronco, Gene G; Palestro, Christopher J

    2015-01-01

    The superiority of SPECT/CT over SPECT for (99m)Tc-sestamibi parathyroid imaging often is assumed to be due to improved lesion localization provided by the anatomic component (computed tomography) of the examination. It also is possible that this superiority may be related to the algorithms used for SPECT data reconstruction. The objective of this investigation was to determine the effect of SPECT reconstruction algorithms on the accuracy of MIBI SPECT/CT parathyroid imaging. We retrospectively analyzed preoperative MIBI SPECT/CT parathyroid imaging studies performed on 106 patients. SPECT data were reconstructed by filtered back projection (FBP) and by iterative reconstruction with corrections for collimator resolution recovery and attenuation (IRC). Two experienced readers independently graded lesion detection certainty on a 5-point scale without knowledge of each other's readings, reconstruction methods, other test results or final diagnoses. All patients had surgical confirmation of the final diagnosis, including disease limited to the neck, and location and weight of excised lesion(s). There were 135 parathyroid lesions among the 106 patients. For FBP SPECT/CT and IRC SPECT/CT sensitivity was 76% and 90% (p = 0.003), specificity was 87% and 87% (p = 0.90), and accuracy was 83% and 88% (p = 0.04), respectively. Inter-rater agreement was significantly higher for IRC than for FBP (kappa = 0.76, "good agreement", versus kappa = 0.58, "moderate agreement", p < 0.0001). We conclude that the improved accuracy of MIBI SPECT/CT compared to MIBI SPECT for preoperative parathyroid lesion localization is due in part to the use of IRC for SPECT data reconstruction.

  19. High-Resolution SPECT-CT/MR Molecular Imaging of Angiogenesis in the Vx2 Model

    PubMed Central

    Lijowski, Michal; Caruthers, Shelton; Hu, Grace; Zhang, Huiying; Scott, Michael J.; Williams, Todd; Erpelding, Todd; Schmieder, Anne H.; Kiefer, Garry; Gulyas, Gyongyi; Athey, Phillip S.; Gaffney, Patrick J.; Wickline, Samuel A.; Lanza, Gregory M.

    2009-01-01

    Background The use of antiangiogenic therapy in conjunction with traditional chemotherapy is becoming increasingly in cancer management, but the optimal benefit of these targeted pharmaceuticals has been limited to a subset of the population treated. Improved imaging probes that permit sensitive detection and high-resolution characterization of tumor angiogenesis could improve patient risk-benefit stratification. Objectives The overarching objective of these experiments was to develop a dual modality αvβ3-targeted nanoparticle molecular imaging agent that affords sensitive nuclear detection in conjunction with high-resolution MR characterization of tumor angiogenesis. Materials and Methods In part 1, New Zealand white rabbits (n = 21) bearing 14d Vx2 tumor received either αvβ3-targeted 99mTc nanoparticles at doses of 11, 22, or 44 MBq/kg, nontargeted 99mTc nanoparticles at 22 MBq/kg, or αvβ3-targeted 99mTc nanoparticles (22 MBq/kg) competitively inhibited with unlabeled αvβ3-nanoparticles. All animals were imaged dynamically over 2 hours with a planar camera using a pinhole collimator. In part 2, the effectiveness of αvβ3-targeted 99mTc nanoparticles in the Vx2 rabbit model was demonstrated using clinical SPECT-CT imaging techniques. Next, MR functionality was incorporated into αvβ3-targeted 99mTc nanoparticles by inclusion of lipophilic gadolinium chelates into the outer phospholipid layer, and the concept of high sensitivity – high-resolution detection and characterization of tumor angiogenesis was shown using sequential SPECT-CT and MR molecular imaging with 3D neovascular mapping. Results αvβ3-Targeted 99mTc nanoparticles at 22 MBq/kg produced the highest tumor-to-muscle contrast ratio (8.56 ± 0.13, TMR) versus the 11MBq/kg (7.32 ± 0.12) and 44 MBq/kg (6.55 ± 0.07) doses, (P < 0.05). TMR of nontargeted particles at 22.2 MBq/kg (5.48 ± 0.09) was less (P < 0.05) than the equivalent dosage of αvβ3-targeted 99mTc nanoparticles. Competitively

  20. Applicability of a set of tomographic reconstruction algorithms for quantitative SPECT on irradiated nuclear fuel assemblies

    NASA Astrophysics Data System (ADS)

    Jacobsson Svärd, Staffan; Holcombe, Scott; Grape, Sophie

    2015-05-01

    A fuel assembly operated in a nuclear power plant typically contains 100-300 fuel rods, depending on fuel type, which become strongly radioactive during irradiation in the reactor core. For operational and security reasons, it is of interest to experimentally deduce rod-wise information from the fuel, preferably by means of non-destructive measurements. The tomographic SPECT technique offers such possibilities through its two-step application; (1) recording the gamma-ray flux distribution around the fuel assembly, and (2) reconstructing the assembly's internal source distribution, based on the recorded radiation field. In this paper, algorithms for performing the latter step and extracting quantitative relative rod-by-rod data are accounted for. As compared to application of SPECT in nuclear medicine, nuclear fuel assemblies present a much more heterogeneous distribution of internal attenuation to gamma radiation than the human body, typically with rods containing pellets of heavy uranium dioxide surrounded by cladding of a zirconium alloy placed in water or air. This inhomogeneity severely complicates the tomographic quantification of the rod-wise relative source content, and the deduction of conclusive data requires detailed modelling of the attenuation to be introduced in the reconstructions. However, as shown in this paper, simplified models may still produce valuable information about the fuel. Here, a set of reconstruction algorithms for SPECT on nuclear fuel assemblies are described and discussed in terms of their quantitative performance for two applications; verification of fuel assemblies' completeness in nuclear safeguards, and rod-wise fuel characterization. It is argued that a request not to base the former assessment on any a priori information brings constraints to which reconstruction methods that may be used in that case, whereas the use of a priori information on geometry and material content enables highly accurate quantitative assessment, which

  1. A flexible high-rate USB2 data acquisition system for PET and SPECT imaging

    SciTech Connect

    J. Proffitt, W. Hammond, S. Majewski, V. Popov, R.R. Raylman, A.G. Weisenberger, R. Wojcik

    2006-02-01

    A new flexible data acquisition system has been developed to instrument gamma-ray imaging detectors designed by the Jefferson Lab Detector and Imaging Group. Hardware consists of 16-channel data acquisition modules installed on USB2 carrier boards. Carriers have been designed to accept one, two, and four modules. Application trigger rate and channel density determines the number of acquisition boards and readout computers used. Each channel has an independent trigger, gated integrator and a 2.5 MHz 12-bit ADC. Each module has an FPGA for analog control and signal processing. Processing includes a 5 ns 40-bit trigger time stamp and programmable triggering, gating, ADC timing, offset and gain correction, charge and pulse-width discrimination, sparsification, event counting, and event assembly. The carrier manages global triggering and transfers module data to a USB buffer. High-granularity time-stamped triggering is suitable for modular detectors. Time stamped events permit dynamic studies, complex offline event assembly, and high-rate distributed data acquisition. A sustained USB data rate of 20 Mbytes/s, a sustained trigger rate of 300 kHz for 32 channels, and a peak trigger rate of 2.5 MHz to FIFO memory were achieved. Different trigger, gating, processing, and event assembly techniques were explored. Target applications include >100 kHz coincidence rate PET detectors, dynamic SPECT detectors, miniature and portable gamma detectors for small-animal and clinical use.

  2. PET and SPECT studies in children with hemispheric low-grade gliomas.

    PubMed

    Juhász, Csaba; Bosnyák, Edit

    2016-10-01

    Molecular imaging is playing an increasing role in the pretreatment evaluation of low-grade gliomas. While glucose positron emission tomography (PET) can be helpful to differentiate low-grade from high-grade tumors, PET imaging with amino acid radiotracers has several advantages, such as better differentiation between tumors and non-tumorous lesions, optimized biopsy targeting, and improved detection of tumor recurrence. This review provides a brief overview of single-photon emission computed tomography (SPECT) studies followed by a more detailed review of the clinical applications of glucose and amino acid PET imaging in low-grade hemispheric gliomas. We discuss key differences in the performance of the most commonly utilized PET radiotracers and highlight the advantage of PET/MRI fusion to obtain optimal information about tumor extent, heterogeneity, and metabolism. Recent data also suggest that simultaneous acquisition of PET/MR images and the combination of advanced MRI techniques with quantitative PET can further improve the pretreatment and post-treatment evaluation of pediatric brain tumors. PMID:27659825

  3. PET and SPECT Imaging for the Acceleration of Anti-Cancer Drug Development.

    PubMed

    Hillyar, Christopher R T; Knight, James C; Vallis, Katherine A; Cornelissen, Bart

    2015-01-01

    Lead-compound optimization is an iterative process in the cancer drug development pipeline, in which small molecule inhibitors or biological compounds that are selected for their ability to bind specific targets are synthesised, tested and optimised. This process can be accelerated significantly using molecular imaging with nuclear medicine techniques, which aim to monitor the biodistribution and pharmacokinetics of radiolabelled versions of compounds. Positron emission tomography (PET) and single-photon emission computed tomography (SPECT) can be used to quantify fourdimensional (temporal and spatial) clinically relevant information, to demonstrate tumor uptake of, and monitor the response to treatment with lead-compounds. This review discusses the pre-clinical and clinical value of the information provided by nuclear medicine imaging compared to the histological analysis of biopsied tissue samples. Also, the role of nuclear medicine imaging is discussed with regard to the assessment of the treatment response, radiotracer biodistribution, tumor accumulation, toxicity, and pharmacokinetic parameters, with mention of microdosing studies, pre-targeting strategies, and pharmacokinetic modelling. PMID:25901527

  4. Influences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3-dimensional brain phantom

    PubMed Central

    Akamatsu, Mana; Yamashita, Yasuo; Akamatsu, Go; Tsutsui, Yuji; Ohya, Nobuyoshi; Nakamura, Yasuhiko; Sasaki, Masayuki

    2014-01-01

    Objective(s): The aim of this study was to evaluate the influences of reconstruction and attenuation correction on the differences in the radioactivity distributions in 123I brain SPECT obtained by the hybrid SPECT/CT device. Methods: We used the 3-dimensional (3D) brain phantom, which imitates the precise structure of gray matter, white matter and bone regions. It was filled with 123I solution (20.1 kBq/mL) in the gray matter region and with K2HPO4 in the bone region. The SPECT/CT data were acquired by the hybrid SPECT/CT device. SPECT images were reconstructed by using filtered back projection with uniform attenuation correction (FBP-uAC), 3D ordered-subsets expectation-maximization with uniform AC (3D-OSEM-uAC) and 3D OSEM with CT-based non-uniform AC (3D-OSEM-CTAC). We evaluated the differences in the radioactivity distributions among these reconstruction methods using a 3D digital phantom, which was developed from CT images of the 3D brain phantom, as a reference. The normalized mean square error (NMSE) and regional radioactivity were calculated to evaluate the similarity of SPECT images to the 3D digital phantom. Results: The NMSE values were 0.0811 in FBP-uAC, 0.0914 in 3D-OSEM-uAC and 0.0766 in 3D-OSEM-CTAC. The regional radioactivity of FBP-uAC was 11.5% lower in the middle cerebral artery territory, and that of 3D-OSEM-uAC was 5.8% higher in the anterior cerebral artery territory, compared with the digital phantom. On the other hand, that of 3D-OSEM-CTAC was 1.8% lower in all brain areas. Conclusion: By using the hybrid SPECT/CT device, the brain SPECT reconstructed by 3D-OSEM with CT attenuation correction can provide an accurate assessment of the distribution of brain radioactivity. PMID:27408856

  5. Initial experience with SPECT imaging of the brain using I-123 p-iodoamphetamine in focal epilepsy

    SciTech Connect

    LaManna, M.M.; Sussman, N.M.; Harner, R.N.; Kaplan, L.R.; Hershey, B.L.; Bernstein, D.R.; Goldstein, P.; Parker, J.A.; Wolodzko, J.G.; Popky, G.L.

    1989-06-01

    Nineteen patients with complex partial seizures refractory to medical treatment were examined with routine electroencephalography (EEG), video EEG monitoring, computed tomography or magnetic resonance imaging, neuropsychological tests and interictal single photon emission computed tomography (SPECT) with I-123 iodoamphetamine (INT). In 18 patients, SPECT identified areas of focal reduction in tracer uptake that correlated with the epileptogenic focus identified on the EEG. In addition, SPECT disclosed other areas of neurologic dysfunction as elicited on neuropsychological tests. Thus, IMP SPECT is a useful tool for localizing epileptogenic foci and their associated dynamic deficits.

  6. Visualization of an Incidental Ectopic Gallbladder Location on 99mTc-MIBI Myocardial Perfusion Imaging With SPECT/CT.

    PubMed

    Hou, Po-Nien; Huang, Cheng-Kai; Wu, Jay

    2016-03-01

    An ectopically located gallbladder is rare and unusual. In this study, we described a case of a 52-year-old woman who underwent SPECT-myocardial perfusion imaging because of exertional dyspnea and chest tightness. The rest sinograms reveal 2 substantially increased tracer uptakes in the right chest. Subsequently, a SPECT/CT scan was performed to clarify the indeterminate findings on the SPECT-myocardial perfusion imaging. The coregistered SPECT/CT images depict intense focal activity in the right chest, which corresponds to the gallbladder on the CT scan, thus explaining the peculiar ectopic gallbladder finding.

  7. Multi-pinhole collimator design for small-object imaging with SiliSPECT: a high-resolution SPECT.

    PubMed

    Shokouhi, S; Metzler, S D; Wilson, D W; Peterson, T E

    2009-01-21

    We have designed a multi-pinhole collimator for a dual-headed, stationary SPECT system that incorporates high-resolution silicon double-sided strip detectors. The compact camera design of our system enables imaging at source-collimator distances between 20 and 30 mm. Our analytical calculations show that using knife-edge pinholes with small-opening angles or cylindrically shaped pinholes in a focused, multi-pinhole configuration in combination with this camera geometry can generate narrow sensitivity profiles across the field of view that can be useful for imaging small objects at high sensitivity and resolution. The current prototype system uses two collimators each containing 127 cylindrically shaped pinholes that are focused toward a target volume. Our goal is imaging objects such as a mouse brain, which could find potential applications in molecular imaging.

  8. Quantitative analysis of L-SPECT system for small animal brain imaging

    NASA Astrophysics Data System (ADS)

    Rahman, Tasneem; Tahtali, Murat; Pickering, Mark R.

    2016-03-01

    This paper aims to investigate the performance of a newly proposed L-SPECT system for small animal brain imaging. The L-SPECT system consists of an array of 100 × 100 micro range diameter pinholes. The proposed detector module has a 48 mm by 48 mm active area and the system is based on a pixelated array of NaI crystals (10×10×10 mm elements) coupled with an array of position sensitive photomultiplier tubes (PSPMTs). The performance of this system was evaluated with pinhole radii of 50 μm, 60 μm and 100 μm. Monte Carlo simulation studies using the Geant4 Application for Tomographic Emission (GATE) software package validate the performance of this novel dual head L-SPECT system where a geometric mouse phantom is used to investigate its performance. All SPECT data were obtained using 120 projection views from 0° to 360° with a 3° step. Slices were reconstructed using conventional filtered back projection (FBP) algorithm. We have evaluated the quality of the images in terms of spatial resolution (FWHM) based on line spread function, the system sensitivity, the point source response function and the image quality. The sensitivity of our newly proposed L- SPECT system was about 4500 cps/μCi at 6 cm along with excellent full width at half-maximum (FWHM) using 50 μm pinhole aperture at several radii of rotation. The analysis results show the combination of excellent spatial resolution and high detection efficiency over an energy range between 20-160 keV. The results demonstrate that SPECT imaging using a pixelated L-SPECT detector module is applicable in a quantitative study of mouse brain imaging.

  9. Improved image quality in pinhole SPECT by accurate modeling of the point spread function in low magnification systems

    SciTech Connect

    Pino, Francisco; Roé, Nuria; Aguiar, Pablo; Falcon, Carles; Ros, Domènec; Pavía, Javier

    2015-02-15

    Purpose: Single photon emission computed tomography (SPECT) has become an important noninvasive imaging technique in small-animal research. Due to the high resolution required in small-animal SPECT systems, the spatially variant system response needs to be included in the reconstruction algorithm. Accurate modeling of the system response should result in a major improvement in the quality of reconstructed images. The aim of this study was to quantitatively assess the impact that an accurate modeling of spatially variant collimator/detector response has on image-quality parameters, using a low magnification SPECT system equipped with a pinhole collimator and a small gamma camera. Methods: Three methods were used to model the point spread function (PSF). For the first, only the geometrical pinhole aperture was included in the PSF. For the second, the septal penetration through the pinhole collimator was added. In the third method, the measured intrinsic detector response was incorporated. Tomographic spatial resolution was evaluated and contrast, recovery coefficients, contrast-to-noise ratio, and noise were quantified using a custom-built NEMA NU 4–2008 image-quality phantom. Results: A high correlation was found between the experimental data corresponding to intrinsic detector response and the fitted values obtained by means of an asymmetric Gaussian distribution. For all PSF models, resolution improved as the distance from the point source to the center of the field of view increased and when the acquisition radius diminished. An improvement of resolution was observed after a minimum of five iterations when the PSF modeling included more corrections. Contrast, recovery coefficients, and contrast-to-noise ratio were better for the same level of noise in the image when more accurate models were included. Ring-type artifacts were observed when the number of iterations exceeded 12. Conclusions: Accurate modeling of the PSF improves resolution, contrast, and recovery

  10. Sci—Thur PM: Imaging — 05: Calibration of a SPECT/CT camera for quantitative SPECT with {sup 99m}Tc

    SciTech Connect

    Gaudin, Émilie; Montégiani, Jean-François; Després, Philippe; Beauregard, Jean-Mathieu

    2014-08-15

    While quantitation is the norm in PET, it is not widely available yet in SPECT. This work's aim was to calibrate a commercially available SPECT/CT system to perform quantitative SPECT. Counting sensitivity, dead-time (DT) constant and partial volume effect (PVE) of the system were assessed. A dual-head Siemens SymbiaT6 SPECT/CT camera equipped with low energy high-resolution collimators was studied. {sup 99m}Tc was the radioisotope of interest because of its wide usage in nuclear medicine. First, point source acquisitions were performed (activity: 30–990MBq). Further acquisitions were then performed with a uniform Jaszczak phantom filled with water at high activity (25–5000MBq). PVE was studied using 6 hot spheres (diameters: 9.9–31.2 mm) filled with {sup 99m}Tc (2.8MBq/cc) in the Jaszczak phantom, which was: (1) empty, (2) water-filled and (3) water-filled with low activity (0.1MBq/cc). The data was reconstructed with the Siemens's Flash3D iterative algorithm with 4 subsets and 8 iterations, attenuation-correction (AC) and scatter-correction (SC). DT modelling was based on the total spectrum counting rate. Sensitivity was assessed using AC-SC reconstructed SPECT data. Sensitivity and DT for the sources were 99.51±1.46cps/MBq and 0.60±0.04µs. For the phantom, sensitivity and DT were 109.9±2.3cps/MBq and 0.62±0.13µs. The recovery-coefficient varied from 5% for the 9.9mm, to 80% for the 31.2mm spheres. With our calibration methods, both sensitivity and DT constant of the SPECT camera had little dependence on the object geometry and attenuation. For small objects of known size, recovery-coefficient can be applied to correct PVE. Clinical quantitative SPECT appears to be possible and has many potential applications.

  11. Patient position alters attenuation effects in multipinhole cardiac SPECT

    SciTech Connect

    Timmins, Rachel; Ruddy, Terrence D.; Wells, R. Glenn

    2015-03-15

    Purpose: Dedicated cardiac cameras offer improved sensitivity over conventional SPECT cameras. Sensitivity gains are obtained by large numbers of detectors and novel collimator arrangements such as an array of multiple pinholes that focus on the heart. Pinholes lead to variable amounts of attenuation as a source is moved within the camera field of view. This study evaluated the effects of this variable attenuation on myocardial SPECT images. Methods: Computer simulations were performed for a set of nine point sources distributed in the left ventricular wall (LV). Sources were placed at the location of the heart in both an anthropomorphic and a water-cylinder computer phantom. Sources were translated in x, y, and z by up to 5 cm from the center. Projections were simulated with and without attenuation and the changes in attenuation were compared. A LV with an inferior wall defect was also simulated in both phantoms over the same range of positions. Real camera data were acquired on a Discovery NM530c camera (GE Healthcare, Haifa, Israel) for five min in list-mode using an anthropomorphic phantom (DataSpectrum, Durham, NC) with 100 MBq of Tc-99m in the LV. Images were taken over the same range of positions as the simulations and were compared based on the summed perfusion score (SPS), defect width, and apparent defect uptake for each position. Results: Point sources in the water phantom showed absolute changes in attenuation of ≤8% over the range of positions and relative changes of ≤5% compared to the apex. In the anthropomorphic computer simulations, absolute change increased to 20%. The changes in relative attenuation caused a change in SPS of <1.5 for the water phantom but up to 4.2 in the anthropomorphic phantom. Changes were larger for axial than for transverse translations. These results were supported by SPS changes of up to six seen in the physical anthropomorphic phantom for axial translations. Defect width was also seen to significantly increase. The

  12. Lung Dose Calculation With SPECT/CT for {sup 90}Yittrium Radioembolization of Liver Cancer

    SciTech Connect

    Yu, Naichang; Srinivas, Shaym M.; DiFilippo, Frank P.; Shrikanthan, Sankaran; Levitin, Abraham; McLennan, Gordon; Spain, James; Xia, Ping; Wilkinson, Allan

    2013-03-01

    Purpose: To propose a new method to estimate lung mean dose (LMD) using technetium-99m labeled macroaggregated albumin ({sup 99m}Tc-MAA) single photon emission CT (SPECT)/CT for {sup 90}Yttrium radioembolization of liver tumors and to compare the LMD estimated using SPECT/CT with clinical estimates of LMD using planar gamma scintigraphy (PS). Methods and Materials: Images of 71 patients who had SPECT/CT and PS images of {sup 99m}Tc-MAA acquired before TheraSphere radioembolization of liver cancer were analyzed retrospectively. LMD was calculated from the PS-based lung shunt assuming a lung mass of 1 kg and 50 Gy per GBq of injected activity shunted to the lung. For the SPECT/CT-based estimate, the LMD was calculated with the activity concentration and lung volume derived from SPECT/CT. The effect of attenuation correction and the patient's breathing on the calculated LMD was studied with the SPECT/CT. With these effects correctly taken into account in a more rigorous fashion, we compared the LMD calculated with SPECT/CT with the LMD calculated with PS. Results: The mean dose to the central region of the lung leads to a more accurate estimate of LMD. Inclusion of the lung region around the diaphragm in the calculation leads to an overestimate of LMD due to the misregistration of the liver activity to the lung from the patient's breathing. LMD calculated based on PS is a poor predictor of the actual LMD. For the subpopulation with large lung shunt, the mean overestimation from the PS method for the lung shunt was 170%. Conclusions: A new method of calculating the LMD for TheraSphere and SIR-Spheres radioembolization of liver cancer based on {sup 99m}Tc-MAA SPECT/CT is presented. The new method provides a more accurate estimate of radiation risk to the lungs. For patients with a large lung shunt calculated from PS, a recalculation of LMD based on SPECT/CT is recommended.

  13. Added-value of SPECT/CT to lymphatic mapping and sentinel lymphadenectomy in gynaecological cancers

    PubMed Central

    Belhocine, Tarik Z; Prefontaine, Michel; Lanvin, Dominique; Bertrand, Monique; Rachinsky, Irina; Ettler, Helen; Zabel, Pamela; Stitt, Larry W; Sugimoto, Akira; Urbain, Jean-Luc

    2013-01-01

    Lymphatic mapping and sentinel lymphadenectomy (LM/SL) have been successfully used in pre-treatment nodal staging of gynaecological cancers. We hypothesised the added-value of LM/SL plus SPECT/CT in patients with early stage of cervical cancer and vulvar cancer. A prospective, single-center, diagnostic, open label, active control, non-randomized clinical trial has been conducted in 7 patients with FIGO IA-IB1 cervical cancer and 7 patients with FIGO stage I-II-IIIcN0 vulvar cancer. All patients underwent LM/SL plus SPECT/low-dose CT and complete lymph node dissection (CLND) according to the standard of care. In case of negative hematoxylin-eosin staining, serial sections of the SLNs were analysed by immunohistochemistry and high molecular weight cytokeratin. Primary outcome measures were the detection rate, the sensitivity (SV), the negative predictive value (NPV), the diagnostic accuracy (DA) for anatomic localisation of SLNs, and the impact on management of SPECT/CT guided LM/SL versus CLND. The secondary outcome measure was the patient tolerability and operating time of LM/SL guided SPECT/CT versus CLND. http://clinicaltrials.gov/show/NCT00773071 All 14 patients were enrolled into the 1-day research protocol with dual-tracer LM/SL and SPECT/CT. Additional SLNs were detected on SPECT/CT compared to conventional planar imaging. Hot and cold > 1cm SLNs were detected on SPECT/CT. Detection rate, SV, NPV, DA were 100% in both groups; false negative rate was 0%. Rate of SLN metastases was 28.5% in cervical cancer and 42.9% in vulvar cancer. Impact on treatment was 28.5% and 14.3% in cervical cancer and vulvar cancer patients, respectively. SPECT/CT was well tolerated by all patients and operating time for LM/SL was within 30 min. No adverse events were reported with a time frame of 1-to-3 years. In early stage of gynaecological cancers, SPECT/low-dose CT is technically feasible and of clinical added-value for LM/SL. PMID:23526734

  14. SemiSPECT: A small-animal single-photon emission computed tomography (SPECT) imager based on eight cadmium zinc telluride (CZT) detector arrays

    SciTech Connect

    Kim, Hyunki; Furenlid, Lars R.; Crawford, Michael J.; Wilson, Donald W.; Barber, H. Bradford; Peterson, Todd E.; Hunter, William C.J.; Liu Zhonglin; Woolfenden, James M.; Barrett, Harrison H.

    2006-02-15

    The first full single-photon emission computed tomography (SPECT) imager to exploit eight compact high-intrinsic-resolution cadmium zinc telluride (CZT) detectors, called SemiSPECT, has been completed. Each detector consists of a CZT crystal and a customized application-specific integrated circuit (ASIC). The CZT crystal is a 2.7 cmx2.7 cmx{approx}0.2 cm slab with a continuous top electrode and a bottom electrode patterned into a 64x64 pixel array by photolithography. The ASIC is attached to the bottom of the CZT crystal by indium-bump bonding. A bias voltage of -180 V is applied to the continuous electrode. The eight detectors are arranged in an octagonal lead-shielded ring. Each pinhole in the eight-pinhole aperture placed at the center of the ring is matched to each individual detector array. An object is imaged onto each detector through a pinhole, and each detector is operated independently with list-mode acquisition. The imaging subject can be rotated about a vertical axis to obtain additional angular projections. The performance of SemiSPECT was characterized using {sup 99m}Tc. When a 0.5 mm diameter pinhole is used, the spatial resolution on each axis is about 1.4 mm as estimated by the Fourier crosstalk matrix, which provides an algorithm-independent average resolution over the field of view. The energy resolution achieved by summing neighboring pixel signals in a 3x3 window is about 10% full-width-at-half-maximum of the photopeak. The overall system sensitivity is about 0.5x10{sup -4} with the energy window of {+-}10% from the photopeak. Line-phantom images are presented to visualize the spatial resolution provided by SemiSPECT, and images of bone, myocardium, and human tumor xenografts in mice demonstrate the feasibility of preclinical small-animal studies with SemiSPECT.

  15. SemiSPECT: A small-animal single-photon emission computed tomography (SPECT) imager based on eight cadmium zinc telluride (CZT) detector arrays

    PubMed Central

    Kim, Hyunki; Furenlid, Lars R.; Crawford, Michael J.; Wilson, Donald W.; Barber, H. Bradford; Peterson, Todd E.; Hunter, William C. J.; Liu, Zhonglin; Woolfenden, James M.; Barrett, Harrison H.

    2008-01-01

    The first full single-photon emission computed tomography (SPECT) imager to exploit eight compact high-intrinsic-resolution cadmium zinc telluride (CZT) detectors, called SemiSPECT, has been completed. Each detector consists of a CZT crystal and a customized application-specific integrated circuit (ASIC). The CZT crystal is a 2.7 cm × 2.7 cm × ~ 0.2 cm slab with a continuous top electrode and a bottom electrode patterned into a 64 × 64 pixel array by photolithography. The ASIC is attached to the bottom of the CZT crystal by indium-bump bonding. A bias voltage of −180 V is applied to the continuous electrode. The eight detectors are arranged in an octagonal lead-shielded ring. Each pinhole in the eight-pinhole aperture placed at the center of the ring is matched to each individual detector array. An object is imaged onto each detector through a pinhole, and each detector is operated independently with list-mode acquisition. The imaging subject can be rotated about a vertical axis to obtain additional angular projections. The performance of SemiSPECT was characterized using 99mTc. When a 0.5 mm diameter pinhole is used, the spatial resolution on each axis is about 1.4 mm as estimated by the Fourier crosstalk matrix, which provides an algorithm-independent average resolution over the field of view. The energy resolution achieved by summing neighboring pixel signals in a 3 × 3 window is about 10% full-width-at-half-maximum of the photopeak. The overall system sensitivity is about 0.5 × 10−4 with the energy window of ±10% from the photopeak. Line-phantom images are presented to visualize the spatial resolution provided by SemiSPECT, and images of bone, myocardium, and human tumor xenografts in mice demonstrate the feasibility of preclinical small-animal studies with SemiSPECT. PMID:16532954

  16. SemiSPECT: a small-animal single-photon emission computed tomography (SPECT) imager based on eight cadmium zinc telluride (CZT) detector arrays.

    PubMed

    Kim, Hyunki; Furenlid, Lars R; Crawford, Michael J; Wilson, Donald W; Barber, H Bradford; Peterson, Todd E; Hunter, William C J; Liu, Zhonglin; Woolfenden, James M; Barrett, Harrison H

    2006-02-01

    The first full single-photon emission computed tomography (SPECT) imager to exploit eight compact high-intrinsic-resolution cadmium zinc telluride (CZT) detectors, called SemiSPECT, has been completed. Each detector consists of a CZT crystal and a customized application-specific integrated circuit (ASIC). The CZT crystal is a 2.7 cm x 2.7 cm x -0.2 cm slab with a continuous top electrode and a bottom electrode patterned into a 64 x 64 pixel array by photolithography. The ASIC is attached to the bottom of the CZT crystal by indium-bump bonding. A bias voltage of -180 V is applied to the continuous electrode. The eight detectors are arranged in an octagonal lead-shielded ring. Each pinhole in the eight-pinhole aperture placed at the center of the ring is matched to each individual detector array. An object is imaged onto each detector through a pinhole, and each detector is operated independently with list-mode acquisition. The imaging subject can be rotated about a vertical axis to obtain additional angular projections. The performance of SemiSPECT was characterized using 99mTc. When a 0.5 mm diameter pinhole is used, the spatial resolution on each axis is about 1.4 mm as estimated by the Fourier crosstalk matrix, which provides an algorithm-independent average resolution over the field of view. The energy resolution achieved by summing neighboring pixel signals in a 3 x 3 window is about 10% full-width-at-half-maximum of the photopeak. The overall system sensitivity is about 0.5 x 10(-4) with the energy window of +/-10% from the photopeak. Line-phantom images are presented to visualize the spatial resolution provided by SemiSPECT, and images of bone, myocardium, and human tumor xenografts in mice demonstrate the feasibility of preclinical small-animal studies with SemiSPECT. PMID:16532954

  17. First use of mini gamma cameras for intra-operative robotic SPECT reconstruction.

    PubMed

    Matthies, Philipp; Sharma, Kanishka; Okur, Ash; Gardiazabal, José; Vogel, Jakob; Lasserl, Tobias; Navab, Nassir

    2013-01-01

    Different types of nuclear imaging systems have been used in the past, starting with pre-operative gantry-based SPECT systems and gamma cameras for 2D imaging of radioactive distributions. The main applications are concentrated on diagnostic imaging, since traditional SPECT systems and gamma cameras are bulky and heavy. With the development of compact gamma cameras with good resolution and high sensitivity, it is now possible to use them without a fixed imaging gantry. Mounting the camera onto a robot arm solves the weight issue, while also providing a highly repeatable and reliable acquisition platform. In this work we introduce a novel robotic setup performing scans with a mini gamma camera, along with the required calibration steps, and show the first SPECT reconstructions. The results are extremely promising, both in terms of image quality as well as reproducibility. In our experiments, the novel setup outperformed a commercial fhSPECT system, reaching accuracies comparable to state-of-the-art SPECT systems.

  18. Role of gallium SPECT-CT in the diagnosis of left ventricular assist device infections.

    PubMed

    Levy, Dana T; Minamoto, Grace Y; Da Silva, Raphaella; Puius, Yoram A; Peck, Naomi; Goldstein, Daniel; D'Alessandro, David; Muggia, Victoria A

    2015-01-01

    Infection remains a well-established complication after the placement of left ventricular assist devices (LVADs). Defining the extent of infection is a challenging task as there are few effective imaging modalities and no standardized guidelines regarding imaging in the diagnosis of device-related infections (DRIs). The use of gallium with single photon emission tomography-computed tomography (Ga-SPECT-CT) has not been previously reported in localizing DRIs. We reviewed the charts and images of five patients with LVADs who underwent Ga-SPECT-CT for the diagnosis of various types of DRIs. Gallium SPECT-CT further clarified the extent of infections among LVAD patients, allowing for patient-specific tailored treatments including surgical debridement. Gallium SPECT-CT is a useful tool when diagnosing LVAD infections and could potentially be the imaging modality of choice in the near future. With improved imaging studies, such as Ga-SPECT-CT, allowing for earlier and more accurate diagnoses of DRIs, the outcome of such infections is likely to improve. PMID:25419830

  19. An investigation of inconsistent projections and artefacts in multi-pinhole SPECT with axially aligned pinholes

    NASA Astrophysics Data System (ADS)

    Kench, P. L.; Lin, J.; Gregoire, M. C.; Meikle, S. R.

    2011-12-01

    Multiple pinholes are advantageous for maximizing the use of the available field of view (FOV) of compact small animal single photon emission computed tomography (SPECT) detectors. However, when the pinholes are aligned axially to optimize imaging of extended objects, such as rodents, multiplexing of the pinhole projections can give rise to inconsistent data which leads to 'ghost point' artefacts in the reconstructed volume. A novel four pinhole collimator with a baffle was designed and implemented to eliminate these inconsistent projections. Simulation and physical phantom studies were performed to investigate artefacts from axially aligned pinholes and the efficacy of the baffle in removing inconsistent data and, thus, reducing reconstruction artefacts. SPECT was performed using a Defrise phantom to investigate the impact of collimator design on FOV utilization and axial blurring effects. Multiple pinhole SPECT acquired with a baffle had fewer artefacts and improved quantitative accuracy when compared to SPECT acquired without a baffle. The use of four pinholes positioned in a square maximized the available FOV, increased acquisition sensitivity and reduced axial blurring effects. These findings support the use of a baffle to eliminate inconsistent projection data arising from axially aligned pinholes and improve small animal SPECT reconstructions.

  20. A new dynamic myocardial phantom for evaluation of SPECT and PET quantitation in systolic and diastolic conditions

    SciTech Connect

    Dreuille, O. de; Bendriem, B.; Riddell, C.

    1996-12-31

    We present a new dynamic myocardial phantom designed to evaluate SPECT and PET imaging in systolic and diastolic conditions. The phantom includes a thoracic attenuating media and the myocardial wall thickness varying during the scan can be performed. In this study the phantom was used with three different wall thickness characteristic of a systolic, end-diastolic and pathologic end-diastolic condition. The myocardium was filled with {sup 99m}Tc, {sup 18}F and Gd and imaged by SPECT, PET and MRI. SPECT attenuation correction was performed using a modified PET transmission. A bull`s eyes image was obtained for all data and wall ROI were then drawn for analysis. Using MRI as a reference, error from PET, SPECT and attenuation corrected SPECT were calculated. Systolic PET performances agree with MRI. Quantitation loss due to wall thickness reduction compared to the systole. Attenuation correction in SPECT leads to significant decrease of the error both in systole (from 29% to 14%) and diastole (35% to 22%). This is particularly sensitive for septum and inferior walls. SPECT residual errors (14% in systole and 22% in pathologic end-diastole) are likely caused by scatter, noise and depth dependent resolution effect. The results obtained with this dynamical phantom demonstrate the quantitation improvement achieved in SPECT with attenuation correction and also reinforce the need for variable resolution correction in addition to attenuation correction.

  1. Longitudinal in vivo evaluation of bone regeneration by combined measurement of multi-pinhole SPECT and micro-CT for tissue engineering

    NASA Astrophysics Data System (ADS)

    Lienemann, Philipp S.; Metzger, Stéphanie; Kiveliö, Anna-Sofia; Blanc, Alain; Papageorgiou, Panagiota; Astolfo, Alberto; Pinzer, Bernd R.; Cinelli, Paolo; Weber, Franz E.; Schibli, Roger; Béhé, Martin; Ehrbar, Martin

    2015-05-01

    Over the last decades, great strides were made in the development of novel implants for the treatment of bone defects. The increasing versatility and complexity of these implant designs request for concurrent advances in means to assess in vivo the course of induced bone formation in preclinical models. Since its discovery, micro-computed tomography (micro-CT) has excelled as powerful high-resolution technique for non-invasive assessment of newly formed bone tissue. However, micro-CT fails to provide spatiotemporal information on biological processes ongoing during bone regeneration. Conversely, due to the versatile applicability and cost-effectiveness, single photon emission computed tomography (SPECT) would be an ideal technique for assessing such biological processes with high sensitivity and for nuclear imaging comparably high resolution (<1 mm). Herein, we employ modular designed poly(ethylene glycol)-based hydrogels that release bone morphogenetic protein to guide the healing of critical sized calvarial bone defects. By combined in vivo longitudinal multi-pinhole SPECT and micro-CT evaluations we determine the spatiotemporal course of bone formation and remodeling within this synthetic hydrogel implant. End point evaluations by high resolution micro-CT and histological evaluation confirm the value of this approach to follow and optimize bone-inducing biomaterials.

  2. Longitudinal in vivo evaluation of bone regeneration by combined measurement of multi-pinhole SPECT and micro-CT for tissue engineering

    PubMed Central

    Lienemann, Philipp S.; Metzger, Stéphanie; Kiveliö, Anna-Sofia; Blanc, Alain; Papageorgiou, Panagiota; Astolfo, Alberto; Pinzer, Bernd R.; Cinelli, Paolo; Weber, Franz E.; Schibli, Roger; Béhé, Martin; Ehrbar, Martin

    2015-01-01

    Over the last decades, great strides were made in the development of novel implants for the treatment of bone defects. The increasing versatility and complexity of these implant designs request for concurrent advances in means to assess in vivo the course of induced bone formation in preclinical models. Since its discovery, micro-computed tomography (micro-CT) has excelled as powerful high-resolution technique for non-invasive assessment of newly formed bone tissue. However, micro-CT fails to provide spatiotemporal information on biological processes ongoing during bone regeneration. Conversely, due to the versatile applicability and cost-effectiveness, single photon emission computed tomography (SPECT) would be an ideal technique for assessing such biological processes with high sensitivity and for nuclear imaging comparably high resolution (<1 mm). Herein, we employ modular designed poly(ethylene glycol)-based hydrogels that release bone morphogenetic protein to guide the healing of critical sized calvarial bone defects. By combined in vivo longitudinal multi-pinhole SPECT and micro-CT evaluations we determine the spatiotemporal course of bone formation and remodeling within this synthetic hydrogel implant. End point evaluations by high resolution micro-CT and histological evaluation confirm the value of this approach to follow and optimize bone-inducing biomaterials. PMID:25989250

  3. Human pancreas scintigraphy using iodine-123-labeled HIPDM and SPECT

    SciTech Connect

    Yamamoto, K.; Shibata, T.; Saji, H.; Kubo, S.; Aoki, E.; Fujita, T.; Yonekura, Y.; Konishi, J.; Yokoyama, A. )

    1990-06-01

    The pancreatic affinity of iodine-123-labeled HIPDM (N,N,N'-trimethyl-N'-(2-hydroxy-3-methyl-5-iodobenzyl)-1,3-propane diamine) (({sup 123}I)HIPDM) was studied in 18 cases (5 normal volunteers, 7 cases with pancreas cancer, and 6 with chronic pancreatitis). In the normal cases, the pancreas was visualized in the planar images as early as 3 hr, and again at 20 hr postinjection. Single-photon emission computed tomography (SPECT) performed following 3-hr planar scintigraphy, provided excellent pancreas images without an overlap of activity in the liver or spleen. The mean pancreas-to-liver (P/L) ratio was 1.26 +/- 0.22 in normal controls. With the exception of one case of massive calcification in the pancreas, the entire pancreas could be observed in the cases with chronic pancreatitis, but the P/L ratio was 0.74 +/- 0.15, significantly lower than that of normal cases. Defective areas of the distal portion of the pancreas were clearly seen in those with cancer of the pancreas. The results of our study indicate that ({sup 123}I) HIPDM may have clinical potential as a human pancreas imaging agent.

  4. The thin plate as a regularizer in Bayesian SPECT reconstruction

    SciTech Connect

    Lee, Soo-Jin; Gindi, G.

    1996-12-31

    The attractions of the maximum-likelihood (ML) method for SPECT reconstruction, namely accurate system and noise modelling, are tempered by its unstable nature. The variety of Bayesian MAP approaches proposed in recent years can both stabilize the reconstructions and lead to better bias and variance. Our own work used a nonquadratic prior (the weak plate) that imposed piecewise smoothness on the first derivative of the solution to achieve results superior to those obtained using a nonquadratic prior (the weak membrane) that imposed piecewise smoothness of the zeroth derivative. By relaxing the requirement of imposing spatial discontinuities and using instead a quadratic (no discontinuities) smoothing prior, algorithms become easier to analyze, solutions easier to compute, and hyperparameter calculation becomes less of a problem. In this work, we investigated whether the advantages of weak plate relative to weak membrane are retained when non-piecewise quadratic versions - the thin plate and membrane priors - are used. We used an EM-OSL (one-step-late) algorithm to compute MAP solutions with both these priors, and found that the thin plate exhibits better bias behavior than the membrane at little cost in variance. Also, both priors outperform ML-EM in terms of bias and variance if practical stopping criteria are used for ML-EM. The net conclusion is that, while quadratic smoothing priors are not as good as piecewise versions, the simple modification of the membrane model to the thin late model leads to improved reconstructions in edge regions.

  5. Tests of scanning model observers for myocardial SPECT imaging

    NASA Astrophysics Data System (ADS)

    Gifford, H. C.; Pretorius, P. H.; Brankov, J. G.

    2009-02-01

    Many researchers have tested and applied human-model observers as part of their evaluations of reconstruction methods for SPECT perfusion imaging. However, these model observers have generally been limited to signal-known- exactly (SKE) detection tasks. Our objective is to formulate and test scanning model observers that emulate humans in detection-localization tasks involving perfusion defects. Herein, we compare several models based on the channelized nonprewhitening (CNPW) observer. Simulated Tc-99m images of the heart with and without defects were created using a mathematical anthropomorphic phantom. Reconstructions were performed with an iterative algorithm and postsmoothed with a 3D Gaussian filter. Human and model-observer studies were conducted to assess the optimal number of iterations and the smoothing level of the filter. The human-observer study was a multiple-alternative forced-choice (MAFC) study with five defects. The CNPW observer performed the MAFC study, but also performed an SKE-but-variable (SKEV) study and a localization ROC (LROC) study. A separate LROC study applied an observer based on models of human search in mammograms. The amount of prior knowledge about the possible defects differed for these four model-observer studies. The trend was towards improved agreement with the human observers as prior knowledge decreased.

  6. Final Progress Report: SPECT Assay of Radiolabeled Monoclonal Antibodies

    SciTech Connect

    Jaszczak, Ronald, J.

    2004-09-30

    During the past project period, we proposed to collaborate closely with DOE’s Thomas Jefferson National Accelerator Facility (Jefferson Lab or JLab) to design a compact, ultra-high-resolution, high-sensitivity gamma camera for quantifying brain-tumor distributions of I-131. We also proposed to continue our on-going research in developing and evaluating pinhole collimation for quantitative ultra-high-resolution imaging of I-131-labeled MAbs. We have made excellent progress in accomplishing much of the research related to pinhole collimation. Many of the most significant results have been presented in peer-reviewed journal articles and conference proceedings. We have also made good progress in collaborating with JLab's Detector Group in developing a compact, ultra-high-resolution, gamma camera. A prototype I-131 imager was delivered to Duke on May 28, 2003. Our research results are summarized in the following sections. A. JLAB-DUKE DEDICATED BRAIN-TUMOR IMAGING SYSTEM A.1. Determination of Optimal Collimator Design During the current project period a prototype I-131 dedicated brain imager has been designed and built. Computer simulations and analysis of alternate designs were performed at Duke to determine an optimal collimator design. Collimator response was characterized by spatial resolution and sensitivity. Both geometric (non-penetrative) and penetrative sensitivities were considered in selecting an optimal collimator design. Based on these simulation results, two collimator designs were selected and built by external vendors. Initial imaging results were obtained using these collimators. B. INITIAL DEVELOPMENT OF SPECT RECONSTRUCTION SOFTWARE FOR JLAB-DUKE CAMERA B.1. Modeling Thick Septa and Collimator Holes: Geometrical-Phantom Study A geometrical phantom was designed to illuminate spatial resolution effects. The phantom includes a uniformly attenuating medium that consists of all voxels within an elliptical cylinder that is centered on the axis of rotation

  7. SPECT scatter modelling in non-uniform attenuating objects

    NASA Astrophysics Data System (ADS)

    Beekman, Freek J.; den Harder, Johan M.; Viergever, Max A.; van Rijk, Peter P.

    1997-06-01

    SPECT quantitation and image contrast are degraded by photon scatter. Water equivalent depths (WEDs) have been used by several investigators to model scatter responses in non-uniform attenuators. The drawback of this approach is the occurrence of undesired fluctuations in the shape of the scatter responses, as is shown by measurements. An improvement of the WED method is presented, based on the assumption that only a part of the scattering object (the region in the `scatter cone') contributes significantly to the detected scatter events. The remaining part of the object is treated as a uniform medium. The extension of the WED method with extra-conical invariance is evaluated by projection measurements of a phantom with a source. Shapes of scatter responses predicted by the method are found to agree better with the measurements than those predicted by conventional WEDs.

  8. A cylindrical SPECT camera with de-centralized readout scheme

    NASA Astrophysics Data System (ADS)

    Habte, F.; Stenström, P.; Rillbert, A.; Bousselham, A.; Bohm, C.; Larsson, S. A.

    2001-09-01

    An optimized brain single photon emission computed tomograph (SPECT) camera is being designed at Stockholm University and Karolinska Hospital. The design goal is to achieve high sensitivity, high-count rate and high spatial resolution. The sensitivity is achieved by using a cylindrical crystal, which gives a closed geometry with large solid angles. A de-centralized readout scheme where only a local environment around the light excitation is readout supports high-count rates. The high resolution is achieved by using an optimized crystal configuration. A 12 mm crystal plus 12 mm light guide combination gave an intrinsic spatial resolution better than 3.5 mm (140 keV) in a prototype system. Simulations show that a modified configuration can improve this value. A cylindrical configuration with a rotating collimator significantly simplifies the mechanical design of the gantry. The data acquisition and control system uses early digitization and subsequent digital signal processing to extract timing and amplitude information, and monitors the position of the collimator. The readout system consists of 12 or more modules each based on programmable logic and a digital signal processor. The modules send data to a PC file server-reconstruction engine via a Firewire (IEEE-1394) network.

  9. Visual-search observers for SPECT simulations with clinical backgrounds

    NASA Astrophysics Data System (ADS)

    Gifford, Howard C.

    2016-03-01

    The purpose of this work was to test the ability of visual-search (VS) model observers to predict the lesion- detection performance of human observers with hybrid SPECT images. These images consist of clinical back- grounds with simulated abnormalities. The application of existing scanning model observers to hybrid images is complicated by the need for extensive statistical information, whereas VS models based on separate search and analysis processes may operate with reduced knowledge. A localization ROC (LROC) study involved the detection and localization of solitary pulmonary nodules in Tc-99m lung images. The study was aimed at op- timizing the number of iterations and the postfiltering of four rescaled block-iterative reconstruction strategies. These strategies implemented different combinations of attenuation correction, scatter correction, and detector resolution correction. For a VS observer in this study, the search and analysis processes were guided by a single set of base morphological features derived from knowledge of the lesion profile. One base set used difference-of- Gaussian channels while a second base set implemented spatial derivatives in combination with the Burgess eye filter. A feature-adaptive VS observer selected features of interest for a given image set on the basis of training-set performance. A comparison of the feature-adaptive observer results against previously acquired human-observer data is presented.

  10. Diagnoses behind patients with hard-to-classify tremor and normal DaT-SPECT: a clinical follow up study.

    PubMed

    Menéndez-González, Manuel; Tavares, Francisco; Zeidan, Nahla; Salas-Pacheco, José M; Arias-Carrión, Oscar

    2014-01-01

    The [(123)I]ioflupane-a dopamine transporter radioligand-SPECT (DaT-SPECT) has proven to be useful in the differential diagnosis of tremor. Here, we investigate the diagnoses behind patients with hard-to-classify tremor and normal DaT-SPECT. Therefore, 30 patients with tremor and normal DaT-SPECT were followed up for 2 years. In 18 cases we were able to make a diagnosis. The residual 12 patients underwent a second DaT-SPECT, were then followed for additional 12 months and thereafter the diagnosis was reconsidered again. The final diagnoses included cases of essential tremor, dystonic tremor, multisystem atrophy, vascular parkinsonism, progressive supranuclear palsy, corticobasal degeneration, fragile X-associated tremor ataxia syndrome, psychogenic parkinsonism, iatrogenic parkinsonism and Parkinson's disease. However, for 6 patients the diagnosis remained uncertain. Larger series are needed to better establish the relative frequency of the different conditions behind these cases. PMID:24744729

  11. Diagnoses behind patients with hard-to-classify tremor and normal DaT-SPECT: a clinical follow up study

    PubMed Central

    Menéndez-González, Manuel; Tavares, Francisco; Zeidan, Nahla; Salas-Pacheco, José M.; Arias-Carrión, Oscar

    2014-01-01

    The [123I]ioflupane—a dopamine transporter radioligand—SPECT (DaT-SPECT) has proven to be useful in the differential diagnosis of tremor. Here, we investigate the diagnoses behind patients with hard-to-classify tremor and normal DaT-SPECT. Therefore, 30 patients with tremor and normal DaT-SPECT were followed up for 2 years. In 18 cases we were able to make a diagnosis. The residual 12 patients underwent a second DaT-SPECT, were then followed for additional 12 months and thereafter the diagnosis was reconsidered again. The final diagnoses included cases of essential tremor, dystonic tremor, multisystem atrophy, vascular parkinsonism, progressive supranuclear palsy, corticobasal degeneration, fragile X–associated tremor ataxia syndrome, psychogenic parkinsonism, iatrogenic parkinsonism and Parkinson's disease. However, for 6 patients the diagnosis remained uncertain. Larger series are needed to better establish the relative frequency of the different conditions behind these cases. PMID:24744729

  12. Feasibility and Initial Performance of Simultaneous SPECT-CT Imaging Using a Commercial Multi-Modality Preclinical Imaging System

    PubMed Central

    Osborne, Dustin R.; Austin, Derek W.

    2015-01-01

    Multi-modality imaging provides coregistered PET-CT and SPECT-CT images; however such multi-modality workflows usually consist of sequential scans from the individual imaging components for each modality. This typical workflow may result in long scan times limiting throughput of the imaging system. Conversely, acquiring multi-modality data simultaneously may improve correlation and registration of images, improve temporal alignment of the acquired data, increase imaging throughput, and benefit the scanned subject by minimizing time under anesthetic. In this work, we demonstrate the feasibility and procedure for modifying a commercially available preclinical SPECT-CT platform to enable simultaneous SPECT-CT acquisition. We also evaluate the performance of simultaneous SPECT-CT tomographic imaging with this modified system. Performance was accessed using a 57Co source and image quality was evaluated with 99mTc phantoms in a series of simultaneous SPECT-CT scans. PMID:26146568

  13. Poster — Thur Eve — 06: Dose assessment of cone beam CT imaging protocols as part of SPECT/CT examinations

    SciTech Connect

    Tonkopi, E; Ross, AA

    2014-08-15

    Purpose: To assess radiation dose from the cone beam CT (CBCT) component of SPECT/CT studies and to compare with other CT examinations performed in our institution. Methods: We used an anthropomorphic chest phantom and the 6 cc ion chamber to measure entrance breast dose for several CBCT and diagnostic CT acquisition protocols. The CBCT effective dose was calculated with ImPACT software; the CT effective dose was evaluated from the DLP value and conversion factor, dependent on the anatomic region. The RADAR medical procedure radiation dose calculator was used to assess the nuclear medicine component of exam dose. Results: The entrance dose to the breast measured with the anthropomorphic phantom was 0.48 mGy and 9.41 mGy for cardiac and chest CBCT scans; and 4.59 mGy for diagnostic thoracic CT. The effective doses were 0.2 mSv, 3.2 mSv and 2.8 mSv respectively. For a small patient represented by the anthropomorphic phantom, the dose from the diagnostic CT was lower than from the CBCT scan, as a result of the exposure reduction options available on modern CT scanners. The CBCT protocols used the same fixed scanning techniques. The diagnostic CT dose based on the patient data was 35% higher than the phantom dose. For most SPECT/CT studies the dose from the CBCT component was comparable with the dose from the radiopharmaceutical. Conclusions: The patient radiation dose from the cone beam CT scan can be higher than that from a diagnostic CT and should be taken into consideration in evaluating total SPECT/CT patient dose.

  14. CT-based quantitative SPECT for the radionuclide ²⁰¹Tl: experimental validation and a standardized uptake value for brain tumour patients.

    PubMed

    Willowson, Kathy; Bailey, Dale; Schembri, Geoff; Baldock, Clive

    2012-01-01

    We have previously reported on a method for reconstructing quantitative data from 99mTc single photon emission computed tomography (SPECT) images based on corrections derived from X-ray computed tomography, producing accurate results in both experimental and clinical studies. This has been extended for use with the radionuclide ²⁰¹Tl. Accuracy was evaluated with experimental phantom studies, including corrections for partial volume effects where necessary. The quantitative technique was used to derive standardized uptake values (SUVs) for ²⁰¹Tl evaluation of brain tumours. A preliminary study was performed on 26 patients using ²⁰¹Tl SPECT scans to assess residual tumor after surgery and then to monitor response to treatment, with a follow-up time of 18 months. Measures of SUVmax were made following quantitative processing of the data and using a threshold grown volume of interest around the tumour. Phantom studies resulted in the calculation of concentration values consistently within 4% of true values. No continuous relation was found between SUVmax (post-resection) and patient survival. Choosing an SUVmax cut-off of 1.5 demonstrated a difference in survival between the 2 groups of patients after surgery. Patients with an SUVmax<1.5 had a 70% survival rate over the first 10 months, compared with a 47% survival rate for those with SUVmax>1.5. This difference did not achieve significance, most likely due to the small study numbers. By 18 months follow-up this difference had reduced, with corresponding survival rates of 40% and 27%, respectively. Although this study involves only a small cohort, it has succeeded in demonstrating the possibility of an SUV measure for SPECT to help monitor response to treatment of brain tumours and predict survival. PMID:22375306

  15. CT-based quantitative SPECT for the radionuclide ²⁰¹Tl: experimental validation and a standardized uptake value for brain tumour patients.

    PubMed

    Willowson, Kathy; Bailey, Dale; Schembri, Geoff; Baldock, Clive

    2012-01-01

    We have previously reported on a method for reconstructing quantitative data from 99mTc single photon emission computed tomography (SPECT) images based on corrections derived from X-ray computed tomography, producing accurate results in both experimental and clinical studies. This has been extended for use with the radionuclide ²⁰¹Tl. Accuracy was evaluated with experimental phantom studies, including corrections for partial volume effects where necessary. The quantitative technique was used to derive standardized uptake values (SUVs) for ²⁰¹Tl evaluation of brain tumours. A preliminary study was performed on 26 patients using ²⁰¹Tl SPECT scans to assess residual tumor after surgery and then to monitor response to treatment, with a follow-up time of 18 months. Measures of SUVmax were made following quantitative processing of the data and using a threshold grown volume of interest around the tumour. Phantom studies resulted in the calculation of concentration values consistently within 4% of true values. No continuous relation was found between SUVmax (post-resection) and patient survival. Choosing an SUVmax cut-off of 1.5 demonstrated a difference in survival between the 2 groups of patients after surgery. Patients with an SUVmax<1.5 had a 70% survival rate over the first 10 months, compared with a 47% survival rate for those with SUVmax>1.5. This difference did not achieve significance, most likely due to the small study numbers. By 18 months follow-up this difference had reduced, with corresponding survival rates of 40% and 27%, respectively. Although this study involves only a small cohort, it has succeeded in demonstrating the possibility of an SUV measure for SPECT to help monitor response to treatment of brain tumours and predict survival.

  16. Cerebral abnormalities in cocaine abusers: Demonstration by SPECT perfusion brain scintigraphy. Work in progress

    SciTech Connect

    Tumeh, S.S.; Nagel, J.S.; English, R.J.; Moore, M.; Holman, B.L. )

    1990-09-01

    Single photon emission computed tomography (SPECT) perfusion brain scans with iodine-123 isopropyl iodoamphetamine (IMP) were obtained in 12 subjects who acknowledged using cocaine on a sporadic to a daily basis. The route of cocaine administration varied from nasal to intravenous. Concurrent abuse of other drugs was also reported. None of the patients were positive for human immunodeficiency virus. Brain scans demonstrated focal defects in 11 subjects, including seven who were asymptomatic, and no abnormality in one. Among the findings were scattered focal cortical deficits, which were seen in several patients and which ranged in severity from small and few to multiple and large, with a special predilection for the frontal and temporal lobes. No perfusion deficits were seen on I-123 SPECT images in five healthy volunteers. Focal alterations in cerebral perfusion are seen commonly in asymptomatic drug users, and these focal deficits are readily depicted by I-123 IMP SPECT.

  17. Bayesian reconstruction strategy of fluorescence-mediated tomography using an integrated SPECT-CT-OT system

    NASA Astrophysics Data System (ADS)

    Cao, Liji; Peter, Jörg

    2010-05-01

    Following the assembly of a triple-modality SPECT-CT-OT small animal imaging system providing intrinsically co-registered projection data of all three submodalities and under the assumption and investigation of dual-labeled probes consisting of both fluorophores and radionuclides, a novel multi-modal reconstruction strategy is presented in this paper aimed at improving fluorescence-mediated tomography (FMT). The following reconstruction procedure is proposed: firstly, standard x-ray CT image reconstruction is performed employing the FDK algorithm. Secondly, standard SPECT image reconstruction is performed using OSEM. Thirdly, from the reconstructed CT volume data the surface boundary of the imaged object is extracted for finite element definition. Finally, the reconstructed SPECT data are used as a priori information within a Bayesian reconstruction framework for optical (FMT) reconstruction. We provide results of this multi-modal approach using phantom experimental data and illustrate that this strategy does suppress artifacts and facilitates quantitative analysis for optical imaging studies.

  18. CT-SPECT fusion to correlate radiolabeled monoclonal antibody uptake with abdominal CT findings

    SciTech Connect

    Kramer, E.L.; Noz, M.E.; Sanger, J.J.; Megibow, A.J.; Maguire, G.Q. )

    1989-09-01

    To enhance the information provided by computed tomography (CT) and single photon emission computed tomography (SPECT) performed with radiolabeled, anti-carcinoembryonic antigen monoclonal antibody (MoAb), the authors performed fusion of these types of images from eight subjects with suspected colorectal adenocarcinoma. Section thickness and pixel size of the two studies were matched, coordinates of corresponding points from each study were identified, and CT sections were translated, rotated, and reprojected to match the corresponding SPECT scans. The CT-SPECT fusion enabled identification of anatomic sites of tumor-specific MoAb accumulation in four cases, showed non-specific MoAb accumulation in two, and helped confirm information only suggested by the two studies separately in one.

  19. Implementation OSEM mesh-domain SPECT reconstruction with explicit prior information

    NASA Astrophysics Data System (ADS)

    Krol, Andrzej; Vogelsang, Levon; Lu, Yao; Xu, Yuesheng; Hu, Xiaofei; Shen, Lixin; Feiglin, David; Lipson, Edward

    2009-02-01

    In order to improve reconstructed image quality, we investigated performance of OSEM mesh-domain SPECT reconstruction with explicit prior anatomical and physiological information that was used to perform accurate attenuation compensation. It was accomplished in the following steps: (i) Obtain anatomical and physiological atlas of desired region of interest; (ii) Generate mesh that encodes properties of the atlas; (iii) Perform initial pixel-based reconstruction on projection dataset; (iv) Register the expected emission atlas to the initial pixel-based reconstruction and apply resulting transformation to meshed atlas; (v) Perform reconstruction in mesh-domain using deformed mesh of the atlas. This approach was tested on synthetic SPECT noise-free and noisy data. Comparative quantitative analysis demonstrated that this method outperformed pixel-based OSEM with uniform AC and is a promising approach that might lead to improved SPECT reconstruction quality.

  20. Novel PET/SPECT Probes for Imaging of Tau in Alzheimer's Disease

    PubMed Central

    Ono, Masahiro

    2015-01-01

    As the world's population ages, the number of patients with Alzheimer's disease (AD) is predicted to increase rapidly. The presence of neurofibrillary tangles (NFTs), composed of hyperphosphorylated tau protein, is one of the neuropathological hallmarks of AD brain. Since the presence of NFTs is well correlated with neurodegeneration and cognitive decline in AD, imaging of tau using positron emission tomography (PET) and single-photon emission computed tomography (SPECT) is useful for presymptomatic diagnosis and monitoring of the progression of AD. Therefore, novel PET/SPECT probes for the imaging of tau have been developed. More recently, several probes were tested clinically and evaluated for their utility. This paper reviews the current state of research on the development and evaluation of PET/SPECT probes for the imaging of tau in AD brain. PMID:25879047

  1. Advances in SPECT for Optimizing the Liver Tumors Radioembolization Using Yttrium-90 Microspheres

    PubMed Central

    Roshan, Hoda Rezaei; Azarm, Ahmadreza; Mahmoudian, Babak; Islamian, Jalil Pirayesh

    2015-01-01

    Radioembolization (RE) with Yttrium-90 (90Y) microspheres is an effective treatment for unresectable liver tumors. The activity of the microspheres to be administered should be calculated based on the type of microspheres. Technetium-99m macroaggregated albumin (99mTc-MAA) single photon emission computed tomography/computed tomography (SPECT/CT) is a reliable assessment before RE to ensure the safe delivery of microspheres into the target. 90Y bremsstrahlung SPECT imaging as a posttherapeutic assessment approach enables the reliable determination of absorbed dose, which is indispensable for the verification of treatment efficacy. This article intends to provide a review of the methods of optimizing 90Y bremsstrahlung SPECT imaging to improve the treatment efficacy of liver tumor RE using 90Y microspheres. PMID:26097416

  2. Impact of hybrid SPECT/CT imaging on the detection of single parathyroid adenoma

    NASA Astrophysics Data System (ADS)

    Morrison, Antony; Brennan, Patrick C.; Reed, Warren; Pietrzyk, Mariusz; Schembri, Geoff; Bailey, Elizabeth; Roach, Paul; Evanoff, Michael; Kench, Peter L.

    2011-03-01

    Objective: The aim of this investigation is to determine the impact of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) on the detection of parathyroid adenoma. Materials and methods: 16 patients presented with suspected parathyroid adenoma localised within the neck. All patients were injected with Tc-99m sestamibi and were scanned with a GE Infinia Hawkeye SPECT/CT. There were six negative and ten positive confirmed cases. Five expert radiologists specializing in nuclear medicine were asked to report on the 16 planar and SPECT data sets and were then asked to report on the same randomly ordered data sets with the addition of CT. Receiver operating characteristic (ROC) analysis was performed using the Dorfman-Berbaum-Metz multireadermulticase methodology and sensitivity and specificity values were generated. A significance level of p <= 0.05 was set for all comparisons. Results: ROC analysis demonstrated an AUC of 0.64 and 0.69 for SPECT and SPECT/CT respectively (p = 0.31). Mean sensitivity scores increased from 0.64 to 0.80 (p = 0.17) and specificity scores decreased from 0.57 to 0.40 (p = 0.17) with the addition of the CT data. Conclusion: This preliminary investigation suggests that extra CT information may increase lesion detection as well as false positive rates for SPECT-based investigations of a single parathyroid adenoma. However the difference in diagnostic efficacy between the two groups was not found to be statistically significant therefore requiring further investigation. These findings have implications beyond the clinical situation described here.

  3. Voxel Based Analysis of Surgical Revascularization for Moyamoya Disease: Pre- and Postoperative SPECT Studies.

    PubMed

    Fushimi, Yasutaka; Okada, Tomohisa; Takagi, Yasushi; Funaki, Takeshi; Takahashi, Jun C; Miyamoto, Susumu; Togashi, Kaori

    2016-01-01

    Moyamoya disease (MMD) is a chronic, progressive, cerebrovascular occlusive disease that causes abnormal enlargement of collateral pathways (moyamoya vessels) in the region of the basal ganglia and thalamus. Cerebral revascularization procedures remain the preferred treatment for patients with MMD, improving the compromised cerebral blood flow (CBF). However, voxel based analysis (VBA) of revascularization surgery for MMD based on data from pre- and postoperative data has not been established. The latest algorithm called as Diffeomorphic Anatomical Registration Through Exponentiated Lie Algebra (DARTEL) has been introduced for VBA as the function of statistical parametric mapping (SPM8), and improved registration has been achieved by SPM8 with DARTEL. In this study, VBA was conducted to evaluate pre- and postoperative single photon emission computed tomography (SPECT) images for MMD by SPM8 with DARTEL algorithm, and the results were compared with those from SPM8 without DARTEL (a conventional method). Thirty-two patients with MMD who underwent superficial temporal artery-middle cerebral artery (STA-MCA) bypass surgery as the first surgery were included and all patients underwent pre- and postoperative 3D T1-weighted imaging and SPECT. Pre- and postoperative SPECT images were registered to 3D T1-weighted images, then VBA was conducted. Postoperative SPECT showed more statistically increased CBF areas in the bypassed side cerebral hemisphere by using SPM8 with DARTEL (58,989 voxels; P<0.001), and increased ratio of CBF after operation was less than 15%. Meanwhile, postoperative SPECT showed less CBF increased areas by SPM8 without DARTEL. In conclusion, VBA was conducted for patients with MMD, and SPM8 with DARTEL revealed that postoperative SPECT showed statistically significant CBF increases over a relatively large area and with at most 15% increase ratio. PMID:26867219

  4. Prognostic evaluation in obese patients using a dedicated multipinhole cadmium-zinc telluride SPECT camera.

    PubMed

    De Lorenzo, Andrea; Peclat, Thais; Amaral, Ana Carolina; Lima, Ronaldo S L

    2016-02-01

    The purpose of this study is to evaluate the prognostic value of myocardial perfusion SPECT obtained in CZT cameras (CZT-SPECT) with multipinhole collimation in obese patients. CZT-SPECT may be technically challenging in the obese, and its prognostic value remains largely unknown. Patients underwent single-day, rest/stress (supine and prone) imaging. Images were visually inspected and graded as poor, fair or good/excellent. Summed stress and difference scores (SSS and SDS, respectively) were converted into percentages of total perfusion defect and of ischemic defect by division by the maximum possible score. Obesity was defined as a body mass index (BMI) ≥ 30 kg/m(2) and classified as class I (BMI 30-34.9 kg/m(2)), II (BMI 35-39.9 kg/m(2)), or III (BMI ≥ 40 kg/m(2)). Patients were followed-up by telephone interview for the occurrence of all-cause death, myocardial infarction or revascularization. A Cox proportional hazards analysis was used to assess the independent predictors of death. Among 1396 patients, 365 (26.1 %) were obese (mean BMI 33.9 ± 3.6; 17.5 % class I, 3.4 % class II, and 3.4 % class III). Image quality was good/excellent in 94.5 % of the obese patients. The annualized mortality rates were not significantly different among obese and non-obese patients, being <1 % with normal CZT-SPECT, and increased with the degree of scan abnormality in both obese and non-obese patients. Age, the use of pharmacologic stress and an abnormal CZT-SPECT, but not obesity, were independent predictors of death. In obese patients, single-day rest/stress CZT-SPECT with a multipinhole camera provides prognostic discrimination with high image quality. PMID:26424491

  5. SPECT Imaging as a Tool for Testing and Challenging Assumptions About Transport in Porous Media

    NASA Astrophysics Data System (ADS)

    Moysey, S. M.; DeVol, T. A.; Tornai, M. P.

    2014-12-01

    Medical imaging has shown promise for unraveling the influence of physical, chemical and biological processes on contaminant transport. Micro-CT scans, for instance, are increasingly utilized to image the pore-scale structure of rocks and soils, which can subsequently be used within modeling studies. A disadvantage of micro-CT, however, is that this imaging modality does not directly detect contaminants. In contrast, Single Photon Emission Computed Tomography (SPECT) can provide the three-dimensional distribution of gamma emitting materials and is thus ideal for imaging the transport of radionuclides. SPECT is of particular interest as a tool for both directly imaging the behavior of long-lived radionuclides of interest, e.g., 99Tc and 137Cs, as well as monitoring shorter-lived isotopes as in-situ tracers of flow and biogeochemical processes. We demonstrate the potential of combining CT and SPECT imaging to improve the mechanistic understanding of flow and transport processes within a heterogeneous porous medium. In the experiment, a column was packed with 0.2mm glass beads with a cylindrical zone of 2mm glass beads embedded near the outlet; this region could be readily identified within the CT images. The column was injected with a pulse of NaCl solution spiked with 99mTcO4- and monitored using SPECT while aliquots of the effluent were used to analyze the breakthrough of both solutes. The breakthrough curves could be approximately replicated by a one-dimensional transport model, but the SPECT data revealed that the tracers migrated around the inclusion of larger beads. Although the zone of large-diameter beads was expected to act as a preferential pathway, the observed behavior could only be replicated in numerical transport simulations if this region was treated as a low-permeability zone relative to the rest of the column. This simple experiment demonstrates the potential of SPECT for investigating flow and transport phenomena within a porous medium.

  6. Voxel Based Analysis of Surgical Revascularization for Moyamoya Disease: Pre- and Postoperative SPECT Studies

    PubMed Central

    Fushimi, Yasutaka; Okada, Tomohisa; Takagi, Yasushi; Funaki, Takeshi; Takahashi, Jun C.; Miyamoto, Susumu; Togashi, Kaori

    2016-01-01

    Moyamoya disease (MMD) is a chronic, progressive, cerebrovascular occlusive disease that causes abnormal enlargement of collateral pathways (moyamoya vessels) in the region of the basal ganglia and thalamus. Cerebral revascularization procedures remain the preferred treatment for patients with MMD, improving the compromised cerebral blood flow (CBF). However, voxel based analysis (VBA) of revascularization surgery for MMD based on data from pre- and postoperative data has not been established. The latest algorithm called as Diffeomorphic Anatomical Registration Through Exponentiated Lie Algebra (DARTEL) has been introduced for VBA as the function of statistical parametric mapping (SPM8), and improved registration has been achieved by SPM8 with DARTEL. In this study, VBA was conducted to evaluate pre- and postoperative single photon emission computed tomography (SPECT) images for MMD by SPM8 with DARTEL algorithm, and the results were compared with those from SPM8 without DARTEL (a conventional method). Thirty-two patients with MMD who underwent superficial temporal artery-middle cerebral artery (STA-MCA) bypass surgery as the first surgery were included and all patients underwent pre- and postoperative 3D T1-weighted imaging and SPECT. Pre- and postoperative SPECT images were registered to 3D T1-weighted images, then VBA was conducted. Postoperative SPECT showed more statistically increased CBF areas in the bypassed side cerebral hemisphere by using SPM8 with DARTEL (58,989 voxels; P<0.001), and increased ratio of CBF after operation was less than 15%. Meanwhile, postoperative SPECT showed less CBF increased areas by SPM8 without DARTEL. In conclusion, VBA was conducted for patients with MMD, and SPM8 with DARTEL revealed that postoperative SPECT showed statistically significant CBF increases over a relatively large area and with at most 15% increase ratio. PMID:26867219

  7. Ectopic Intrathymic Parathyroid adenoma demonstrated on Tc-99m Sestamibi SPECT-CT.

    PubMed

    Usmani, S; Oteifa, M; Abu Huda, F; Javaid, A; Amanguno, H G; Al Kandari, F

    2016-05-01

    Intrathymic parathyroid adenoma is a rare cause of primary hyperparathyroidism. In this case, Tc-99m Sestamibi SPECT-CT successfully localized abnormal tracer uptake in the mediastinum with corresponding low density lesion on CT images suggestive of mediastinal parathyroid adenoma which late on confirmed on histopathology. After the median sternotomy a large intrathymic parathyroid adenoma was identified and excised. With the help of gamma probe the surgeons detect the lesion early and with more confidence as well as reducing the total operation time. Tc-99m Sestamibi SPECT-CT scintigraphy and gamma probe localization is recommended for preoperative and intra operative localization of ectopic parathyroid adenomas.

  8. First Results of Small Animal Imaging Spect Detector for Cardiovascular Disease Studies on Mice

    NASA Astrophysics Data System (ADS)

    Magliozzi, M. L.; Ballerini, M.; Cisbani, E.; Colilli, S.; Cusanno, F.; Fratoni, R.; Garibaldi, F.; Giuliani, F.; Gricia, M.; Lucentini, M.; Santavenere, F.; Torrioli, S.; Veneroni, P.; Majewsky, S.; Mok, S. P. G.; Tsui, B. M. W.; Wang, Y.; Marano, G.; Musumeci, M.; Palazzesi, S.; Ciccariello, G.; de Vincentis, G.; Accorsi, R.

    2008-06-01

    We have developed a compact, open, Dual Head pinhole SPECT system for high resolution molecular imaging with radionuclides of mice, dedicated mainly to preclinical study of stem cells capability to recover myocardial infarction. The gamma detector is made of pinhole tungsten collimators, pixellated scintillators, matrix of multi-anode PMTs and individual channel readout. Measurements have been performed on phantoms and live mice devoted initially to test and calibrate the system and to optimize protocols. The implemented system and the first results will be presented, demonstrating the effectiveness of our dedicated SPECT detector for small animal imaging.

  9. A hardware investigation of robotic SPECT for functional and molecular imaging onboard radiation therapy systems

    PubMed Central

    Yan, Susu; Bowsher, James; Tough, MengHeng; Cheng, Lin; Yin, Fang-Fang

    2014-01-01

    Purpose: To construct a robotic SPECT system and to demonstrate its capability to image a thorax phantom on a radiation therapy flat-top couch, as a step toward onboard functional and molecular imaging in radiation therapy. Methods: A robotic SPECT imaging system was constructed utilizing a gamma camera detector (Digirad 2020tc) and a robot (KUKA KR150 L110 robot). An imaging study was performed with a phantom (PET CT PhantomTM), which includes five spheres of 10, 13, 17, 22, and 28 mm diameters. The phantom was placed on a flat-top couch. SPECT projections were acquired either with a parallel-hole collimator or a single-pinhole collimator, both without background in the phantom and with background at 1/10th the sphere activity concentration. The imaging trajectories of parallel-hole and pinhole collimated detectors spanned 180° and 228°, respectively. The pinhole detector viewed an off-centered spherical common volume which encompassed the 28 and 22 mm spheres. The common volume for parallel-hole system was centered at the phantom which encompassed all five spheres in the phantom. The maneuverability of the robotic system was tested by navigating the detector to trace the phantom and flat-top table while avoiding collision and maintaining the closest possible proximity to the common volume. The robot base and tool coordinates were used for image reconstruction. Results: The robotic SPECT system was able to maneuver parallel-hole and pinhole collimated SPECT detectors in close proximity to the phantom, minimizing impact of the flat-top couch on detector radius of rotation. Without background, all five spheres were visible in the reconstructed parallel-hole image, while four spheres, all except the smallest one, were visible in the reconstructed pinhole image. With background, three spheres of 17, 22, and 28 mm diameters were readily observed with the parallel-hole imaging, and the targeted spheres (22 and 28 mm diameters) were readily observed in the pinhole

  10. End-expiration Respiratory Gating for a High Resolution Stationary Cardiac SPECT system

    PubMed Central

    Chan, Chung; Harris, Mark; Le, Max; Biondi, James; Grobshtein, Yariv; Liu, Yi-Hwa; Sinusas, Albert J.; Liu, Chi

    2014-01-01

    Respiratory and cardiac motions can degrade myocardial perfusion SPECT (MPS) image quality and reduce defect detection and quantitative accuracy. In this study, we developed a dual-respiratory and cardiac gating system for a high resolution fully stationary cardiac SPECT scanner in order to improve the image quality and defect detection. Respiratory motion was monitored using a compressive sensor pillow connected to a dual respiratory-cardiac gating box, which sends cardiac triggers only during end-expiration phases to the single cardiac trigger input on the SPECT scanners. The listmode data were rebinned retrospectively into end-expiration frames for respiratory motion reduction or 8 cardiac gates only during end-expiration phases to compensate for both respiratory and cardiac motions. The proposed method was first validated on a motion phantom in the presence and absence of multiple perfusion defects, and then applied on 11 patient studies with and without perfusion defects. In the normal phantom studies, the end-expiration gated SPECT (EXG-SPECT) reduced respiratory motion blur and increased myocardium to blood pool contrast by 51.2% as compared to the ungated images. The proposed method also yielded an average of 11.2% increase in myocardium to defect contrast as compared to the ungated images in the phantom studies with perfusion defects. In the patient studies, EXG-SPECT significantly improved the myocardium to blood pool contrast (p<0.005) by 24% on average as compared to the ungated images, and led to improved perfusion uniformity across segments on polar maps for normal patients. For a patient with defect, EXG-SPECT improved the defect contrast and definition. The dual respiratory-cardiac gating further reduced the blurring effect, increased the myocardium to blood pool contrast significantly by 36% (p<0.05) compared to EXG SPECT, and further improved defect characteristics and visualization of fine structures at the expense of increased noise on the

  11. End-expiration respiratory gating for a high-resolution stationary cardiac SPECT system

    NASA Astrophysics Data System (ADS)

    Chan, Chung; Harris, Mark; Le, Max; Biondi, James; Grobshtein, Yariv; Liu, Yi-Hwa; Sinusas, Albert J.; Liu, Chi

    2014-10-01

    Respiratory and cardiac motions can degrade myocardial perfusion SPECT (MPS) image quality and reduce defect detection and quantitative accuracy. In this study, we developed a dual respiratory and cardiac gating system for a high-resolution fully stationary cardiac SPECT scanner in order to improve the image quality and defect detection. Respiratory motion was monitored using a compressive sensor pillow connected to a dual respiratory-cardiac gating box, which sends cardiac triggers only during end-expiration phases to the single cardiac trigger input on the SPECT scanners. The listmode data were rebinned retrospectively into end-expiration frames for respiratory motion reduction or eight cardiac gates only during end-expiration phases to compensate for both respiratory and cardiac motions. The proposed method was first validated on a motion phantom in the presence and absence of multiple perfusion defects, and then applied on 11 patient studies with and without perfusion defects. In the normal phantom studies, the end-expiration gated SPECT (EXG-SPECT) reduced respiratory motion blur and increased myocardium to blood pool contrast by 51.2% as compared to the ungated images. The proposed method also yielded an average of 11.2% increase in myocardium to defect contrast as compared to the ungated images in the phantom studies with perfusion defects. In the patient studies, EXG-SPECT significantly improved the myocardium to blood pool contrast (p < 0.005) by 24% on average as compared to the ungated images, and led to improved perfusion uniformity across segments on polar maps for normal patients. For a patient with defect, EXG-SPECT improved the defect contrast and definition. The dual respiratory-cardiac gating further reduced the blurring effect, increased the myocardium to blood pool contrast significantly by 36% (p < 0.05) compared to EXG-SPECT, and further improved defect characteristics and visualization of fine structures at the expense of increased noise on

  12. A hardware investigation of robotic SPECT for functional and molecular imaging onboard radiation therapy systems

    SciTech Connect

    Yan, Susu Tough, MengHeng; Bowsher, James; Yin, Fang-Fang; Cheng, Lin

    2014-11-01

    Purpose: To construct a robotic SPECT system and to demonstrate its capability to image a thorax phantom on a radiation therapy flat-top couch, as a step toward onboard functional and molecular imaging in radiation therapy. Methods: A robotic SPECT imaging system was constructed utilizing a gamma camera detector (Digirad 2020tc) and a robot (KUKA KR150 L110 robot). An imaging study was performed with a phantom (PET CT Phantom{sup TM}), which includes five spheres of 10, 13, 17, 22, and 28 mm diameters. The phantom was placed on a flat-top couch. SPECT projections were acquired either with a parallel-hole collimator or a single-pinhole collimator, both without background in the phantom and with background at 1/10th the sphere activity concentration. The imaging trajectories of parallel-hole and pinhole collimated detectors spanned 180° and 228°, respectively. The pinhole detector viewed an off-centered spherical common volume which encompassed the 28 and 22 mm spheres. The common volume for parallel-hole system was centered at the phantom which encompassed all five spheres in the phantom. The maneuverability of the robotic system was tested by navigating the detector to trace the phantom and flat-top table while avoiding collision and maintaining the closest possible proximity to the common volume. The robot base and tool coordinates were used for image reconstruction. Results: The robotic SPECT system was able to maneuver parallel-hole and pinhole collimated SPECT detectors in close proximity to the phantom, minimizing impact of the flat-top couch on detector radius of rotation. Without background, all five spheres were visible in the reconstructed parallel-hole image, while four spheres, all except the smallest one, were visible in the reconstructed pinhole image. With background, three spheres of 17, 22, and 28 mm diameters were readily observed with the parallel-hole imaging, and the targeted spheres (22 and 28 mm diameters) were readily observed in the

  13. End-expiration respiratory gating for a high-resolution stationary cardiac SPECT system.

    PubMed

    Chan, Chung; Harris, Mark; Le, Max; Biondi, James; Grobshtein, Yariv; Liu, Yi-Hwa; Sinusas, Albert J; Liu, Chi

    2014-10-21

    Respiratory and cardiac motions can degrade myocardial perfusion SPECT (MPS) image quality and reduce defect detection and quantitative accuracy. In this study, we developed a dual respiratory and cardiac gating system for a high-resolution fully stationary cardiac SPECT scanner in order to improve the image quality and defect detection. Respiratory motion was monitored using a compressive sensor pillow connected to a dual respiratory-cardiac gating box, which sends cardiac triggers only during end-expiration phases to the single cardiac trigger input on the SPECT scanners. The listmode data were rebinned retrospectively into end-expiration frames for respiratory motion reduction or eight cardiac gates only during end-expiration phases to compensate for both respiratory and cardiac motions. The proposed method was first validated on a motion phantom in the presence and absence of multiple perfusion defects, and then applied on 11 patient studies with and without perfusion defects. In the normal phantom studies, the end-expiration gated SPECT (EXG-SPECT) reduced respiratory motion blur and increased myocardium to blood pool contrast by 51.2% as compared to the ungated images. The proposed method also yielded an average of 11.2% increase in myocardium to defect contrast as compared to the ungated images in the phantom studies with perfusion defects. In the patient studies, EXG-SPECT significantly improved the myocardium to blood pool contrast (p < 0.005) by 24% on average as compared to the ungated images, and led to improved perfusion uniformity across segments on polar maps for normal patients. For a patient with defect, EXG-SPECT improved the defect contrast and definition. The dual respiratory-cardiac gating further reduced the blurring effect, increased the myocardium to blood pool contrast significantly by 36% (p < 0.05) compared to EXG-SPECT, and further improved defect characteristics and visualization of fine structures at the expense of increased noise

  14. Design of a digital phantom population for myocardial perfusion SPECT imaging research

    NASA Astrophysics Data System (ADS)

    Ghaly, Michael; Du, Yong; Fung, George S. K.; Tsui, Benjamin M. W.; Links, Jonathan M.; Frey, Eric

    2014-06-01

    Digital phantoms and Monte Carlo (MC) simulations have become important tools for optimizing and evaluating instrumentation, acquisition and processing methods for myocardial perfusion SPECT (MPS). In this work, we designed a new adult digital phantom population and generated corresponding Tc-99m and Tl-201 projections for use in MPS research. The population is based on the three-dimensional XCAT phantom with organ parameters sampled from the Emory PET Torso Model Database. Phantoms included three variations each in body size, heart size, and subcutaneous adipose tissue level, for a total of 27 phantoms of each gender. The SimSET MC code and angular response functions were used to model interactions in the body and the collimator-detector system, respectively. We divided each phantom into seven organs, each simulated separately, allowing use of post-simulation summing to efficiently model uptake variations. Also, we adapted and used a criterion based on the relative Poisson effective count level to determine the required number of simulated photons for each simulated organ. This technique provided a quantitative estimate of the true noise in the simulated projection data, including residual MC simulation noise. Projections were generated in 1 keV wide energy windows from 48-184 keV assuming perfect energy resolution to permit study of the effects of window width, energy resolution, and crosstalk in the context of dual isotope MPS. We have developed a comprehensive method for efficiently simulating realistic projections for a realistic population of phantoms in the context of MPS imaging. The new phantom population and realistic database of simulated projections will be useful in performing mathematical and human observer studies to evaluate various acquisition and processing methods such as optimizing the energy window width, investigating the effect of energy resolution on image quality and evaluating compensation methods for degrading factors such as crosstalk in

  15. Comparison of the scanning linear estimator (SLE) and ROI methods for quantitative SPECT imaging

    NASA Astrophysics Data System (ADS)

    Könik, Arda; Kupinski, Meredith; Hendrik Pretorius, P.; King, Michael A.; Barrett, Harrison H.

    2015-08-01

    In quantitative emission tomography, tumor activity is typically estimated from calculations on a region of interest (ROI) identified in the reconstructed slices. In these calculations, unpredictable bias arising from the null functions of the imaging system affects ROI estimates. The magnitude of this bias depends upon the tumor size and location. In prior work it has been shown that the scanning linear estimator (SLE), which operates on the raw projection data, is an unbiased estimator of activity when the size and location of the tumor are known. In this work, we performed analytic simulation of SPECT imaging with a parallel-hole medium-energy collimator. Distance-dependent system spatial resolution and non-uniform attenuation were included in the imaging simulation. We compared the task of activity estimation by the ROI and SLE methods for a range of tumor sizes (diameter: 1-3 cm) and activities (contrast ratio: 1-10) added to uniform and non-uniform liver backgrounds. Using the correct value for the tumor shape and location is an idealized approximation to how task estimation would occur clinically. Thus we determined how perturbing this idealized prior knowledge impacted the performance of both techniques. To implement the SLE for the non-uniform background, we used a novel iterative algorithm for pre-whitening stationary noise within a compact region. Estimation task performance was compared using the ensemble mean-squared error (EMSE) as the criterion. The SLE method performed substantially better than the ROI method (i.e. EMSE(SLE) was 23-174 times lower) when the background is uniform and tumor location and size are known accurately. The variance of the SLE increased when a non-uniform liver texture was introduced but the EMSE(SLE) continued to be 5-20 times lower than the ROI method. In summary, SLE outperformed ROI under almost all conditions that we tested.

  16. Design of a digital phantom population for myocardial perfusion SPECT imaging research

    PubMed Central

    Ghaly, Michael; Du, Yong; Fung, George S.K.; Tsui, Benjamin M.W.; Links, Jonathan M.; Frey, Eric

    2014-01-01

    Digital phantoms and Monte Carlo (MC) simulations have become important tools for optimizing and evaluating instrumentation, acquisition and processing methods for myocardial perfusion SPECT (MPS). In this work, we designed a new adult digital phantom population and generated corresponding Tc-99m and Tl-201 projections for use in MPS research. The population is based on the 3D XCAT phantom with organ parameters sampled from the Emory PET Torso Model Database. Phantoms included 3 variations each in body size, heart size, and subcutaneous adipose tissue level, for a total of 27 phantoms of each gender. The SimSET Monte Carlo code and angular response functions were used to model interactions in the body and the collimator-detector system, respectively. We divided each phantom into seven organs, each simulated separately, allowing use of post-simulation summing to efficiently model uptake variations. Also, we adapted and used a criterion based on the relative Poisson effective count level to determine the required number of simulated photons for each simulated organ. This technique provided a quantitative estimate of the true noise in the simulated projection data, including residual MC simulation noise. Projections were generated in 1 keV wide energy windows from 48-184 keV assuming perfect energy resolution to permit study of the effects of window width, energy resolution, and crosstalk in the context of dual isotope MPS. We have developed a comprehensive method for efficiently simulating realistic projections for a realistic population of phantoms in the context of MPS imaging. The new phantom population and realistic database of simulated projections will be useful in performing mathematical and human observer studies to evaluate various acquisition and processing methods such as optimizing the energy window width, investigating the effect of energy resolution on image quality and evaluating compensation methods for degrading factors such as crosstalk in the

  17. LROC assessment of non-linear filtering methods in Ga-67 SPECT imaging

    NASA Astrophysics Data System (ADS)

    De Clercq, Stijn; Staelens, Steven; De Beenhouwer, Jan; D'Asseler, Yves; Lemahieu, Ignace

    2006-03-01

    In emission tomography, iterative reconstruction is usually followed by a linear smoothing filter to make such images more appropriate for visual inspection and diagnosis by a physician. This will result in a global blurring of the images, smoothing across edges and possibly discarding valuable image information for detection tasks. The purpose of this study is to investigate which possible advantages a non-linear, edge-preserving postfilter could have on lesion detection in Ga-67 SPECT imaging. Image quality can be defined based on the task that has to be performed on the image. This study used LROC observer studies based on a dataset created by CPU-intensive Gate Monte Carlo simulations of a voxelized digital phantom. The filters considered in this study were a linear Gaussian filter, a bilateral filter, the Perona-Malik anisotropic diffusion filter and the Catte filtering scheme. The 3D MCAT software phantom was used to simulate the distribution of Ga-67 citrate in the abdomen. Tumor-present cases had a 1-cm diameter tumor randomly placed near the edges of the anatomical boundaries of the kidneys, bone, liver and spleen. Our data set was generated out of a single noisy background simulation using the bootstrap method, to significantly reduce the simulation time and to allow for a larger observer data set. Lesions were simulated separately and added to the background afterwards. These were then reconstructed with an iterative approach, using a sufficiently large number of MLEM iterations to establish convergence. The output of a numerical observer was used in a simplex optimization method to estimate an optimal set of parameters for each postfilter. No significant improvement was found for using edge-preserving filtering techniques over standard linear Gaussian filtering.

  18. Compensation for non-uniform attenuation in SPECT brain imaging

    SciTech Connect

    Glick, S.J.; King, M.A.; Pan, T.S.

    1994-05-01

    Photon attenuation is a major limitation in performing quantitative SPECT brain imaging. A number of methods have been proposed for compensation of attenuation in regions of the body that can be modelled as a uniform attenuator. The magnitude of the errors introduced into reconstructed brain images by assuming the head to be a uniform attenuator are uncertain (the skull, sinus cavities and head holder all have different attenuation properties than brain tissue). Brain imaging is unique in that the radioisotope, for the most part, is taken up within a uniform attenuation medium (i.e., brain tissue) which is surrounded by bone (i.e., the skull) of a different density. Using this observation, Bellini`s method for attenuation compensation (which is an exact solution to the exponential Radon transform) has been modified to account for the different attenuation properties of the skull. To test this modified Bellini method, a simple mathematical phantom was designed to model the brain and a skull of varying thickness less than 7.5 mm. To model brain imaging with Tc-99m HMPAO, the attenuation coefficient of the brain tissue and skull were set to 0.15 cm{sup -1} and 0.22 cm{sup -1} respectively. A ray-driven projector which accounted for non-uniform attenuation was used to simulate projection data from 128 views. The detector response and scatter were not simulated. It was observed that reconstructions processed with uniform attenuation compensation (i.e., where it was assumed that the brain tissue and the skull had the same attenuation coefficient) provided errors of 6-20%, whereas those processed with the non-uniform Bellini algorithm were biased by only 0-5%.

  19. The effect of truncation on very small cardiac SPECT camerasystems

    SciTech Connect

    Rohmer, Damien; Eisner, Robert L.; Gullberg, Grant T.

    2006-08-01

    Background: The limited transaxial field-of-view (FOV) of avery small cardiac SPECT camera system causes view-dependent truncationof the projection of structures exterior to, but near the heart. Basictomographic principles suggest that the reconstruction of non-attenuatedtruncated data gives a distortion-free image in the interior of thetruncated region, but the DC term of the Fourier spectrum of thereconstructed image is incorrect, meaning that the intensity scale of thereconstruction is inaccurate. The purpose of this study was tocharacterize the reconstructed image artifacts from truncated data, andto quantify their effects on the measurement of tracer uptake in themyocardial. Particular attention was given to instances where the heartwall is close to hot structures (structures of high activity uptake).Methods: The MCAT phantom was used to simulate a 2D slice of the heartregion. Truncated and non-truncated projections were formed both with andwithout attenuation. The reconstructions were analyzed for artifacts inthe myocardium caused by truncation, and for the effect that attenuationhas relative to increasing those artifacts. Results: The inaccuracy dueto truncation is primarily caused by an incorrect DC component. Forvisualizing theleft ventricular wall, this error is not worse than theeffect of attenuation. The addition of a small hot bowel-like structurenear the left ventricle causes few changes in counts on the wall. Largerartifacts due to the truncation are located at the boundary of thetruncation and can be eliminated by sinogram interpolation. Finally,algebraic reconstruction methods are shown to give better reconstructionresults than an analytical filtered back-projection reconstructionalgorithm. Conclusion: Small inaccuracies in reconstructed images fromsmall FOV camera systems should have little effect on clinicalinterpretation. However, changes in the degree of inaccuracy in countsfrom slice toslice are due to changes in the truncated structures

  20. Potential for SPECT cameras utilizing photodiode readout of scintillator crystals

    SciTech Connect

    Moses, W.W.; Derenzo, S.E.; Gruber, G.J.; Huesman, R.H.

    1997-05-01

    We present a conceptual design for a SPECT detector consisting of an array of 3x3x5 mm CsI(Tl) scintillator crystals individually read out by an array of 3 mm square silicon photodiodes. The interaction position is not determined by Anger logic, but by the location of the individual crystal/photodiode element in which the gamma ray is observed. Since the design is modular (each module typically having 64 crystals, photodiodes, and charge amplifiers, and one multiplexer circuit to reduce the number of readout channels), a large variety of camera geometries can be realized. Advantages of this design over conventional cameras (NaI(Tl) scintillator/photomultiplier tube) are lower gain drift (i.e. higher stability), smaller size, significantly higher count rate capability, and potentially lower cost. For the 141 keV emissions of Tc-99m, both CsI(Tl) and NaI(Tl) have 85-90% photoelectric fraction, but CsI(TI) has an attenuation length of 3.0 mm as compared to 4.5 mm for NaI(Tl). Thus, a 5 mm thick CsI(Tl) camera has singular efficiency to a Nal(Tl) camera with a 7.5 mm thickness (between 1/4 and 3/8 inch). The light output of CsI(Tl) is 25% higher than that of Nal(Tl), and while its 565 nm emissions are not efficiently detected with photomultiplier tubes, they are well matched to photodiode detection.

  1. Assessment of the severity of partial volume effects and the performance of two template-based correction methods in a SPECT/CT phantom experiment.

    PubMed

    Shcherbinin, S; Celler, A

    2011-08-21

    We investigated the severity of partial volume effects (PVE), which may occur in SPECT/CT studies, and the performance of two template-based correction techniques. A hybrid SPECT/CT system was used to scan a thorax phantom that included lungs, a heart insert and six cylindrical containers of different sizes and activity concentrations. This phantom configuration allowed us to have non-uniform background activity and a combination of spill-in and spill-out effects for several compartments. The reconstruction with corrections for attenuation, scatter and resolution loss but not PVE correction accurately recovered absolute activities in large organs. However, the activities inside segmented 17-120 mL containers were underestimated by 20%-40%. After applying our PVE correction to the data pertaining to six small containers, the accuracy of the recovered total activity improved with errors ranging between 3% and 22% (non-iterative method) and between 5% and 15% (method with an iteratively updated background activity). While the non-iterative template-based algorithm demonstrated slightly better accuracy for cases with less severe PVE than the iterative algorithm, it underperformed in situations with considerable spill out and/or mixture of spill-in and spill-out effects.

  2. New method for tuning hyperparameter for the total variation norm in the maximum a posteriori ordered subsets expectation maximization reconstruction in SPECT myocardial perfusion imaging

    NASA Astrophysics Data System (ADS)

    Yang, Zhaoxia; Krol, Andrzej; Xu, Yuesheng; Feiglin, David H.

    2011-03-01

    In order to improve the tradeoff between noise and bias, and to improve uniformity of the reconstructed myocardium while preserving spatial resolution in parallel-beam collimator SPECT myocardial perfusion imaging (MPI) we investigated the most advantageous approach to provide reliable estimate of the optimal value of hyperparameter for the Total Variation (TV) norm in the iterative Bayesian Maximum A Posteriori Ordered Subsets Expectation Maximization (MAP-OSEM) one step late tomographic reconstruction with Gibbs prior. Our aim was to find the optimal value of hyperparameter corresponding to the lowest bias at the lowest noise while maximizing uniformity and spatial resolution for the reconstructed myocardium in SPECT MPI. We found that the L-curve method that is by definition a global technique provides good guidance for selection of the optimal value of the hyperparameter. However, for a heterogeneous object such as human thorax the fine-tuning of the hyperparameter's value can be only accomplished by means of a local method such as the proposed bias-noise distance (BND) curve. We established that our BND-curve method provides accurate optimized hyperparameter's value estimation as long as the region of interest volume for which it is defined is sufficiently large and is located sufficiently close to the myocardium.

  3. SuSpect: A Fortran code for the Supersymmetric and Higgs particle spectrum in the MSSM

    NASA Astrophysics Data System (ADS)

    Djouadi, Abdelhak; Kneur, Jean-Loïc; Moultaka, Gilbert

    2007-03-01

    We present the FORTRAN code SuSpect version 2.3, which calculates the Supersymmetric and Higgs particle spectrum in the Minimal Supersymmetric Standard Model (MSSM). The calculation can be performed in constrained models with universal boundary conditions at high scales such as the gravity (mSUGRA), anomaly (AMSB) or gauge (GMSB) mediated supersymmetry breaking models, but also in the non-universal MSSM case with R-parity and CP conservation. Care has been taken to treat important features such as the renormalization group evolution of parameters between low and high energy scales, the consistent implementation of radiative electroweak symmetry breaking and the calculation of the physical masses of the Higgs bosons and supersymmetric particles taking into account the dominant radiative corrections. Some checks of important theoretical and experimental features, such as the absence of non-desired minima, large fine-tuning in the electroweak symmetry breaking condition, as well as agreement with precision measurements can be performed. The program is simple to use, self-contained and can easily be linked to other codes; it is rather fast and flexible, thus allowing scans of the parameter space with several possible options and choices for model assumptions and approximations. Catalogue identifier:ADYR_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADYR_v1_0 Program obtainable from: CPC Program Library, Queen's University of Belfast, N. Ireland Licensing provisions:none Programming language used:FORTRAN 77 Computer:Unix machines, PC No. of lines in distributed program, including test data, etc.:21 821 No. of bytes in distributed program, including test data, etc.:249 657 Distribution format:tar.gz Operating system:Unix (or Linux) RAM:approximately 2500 Kbytes Number of processors used:1 processor Nature of problem:SuSpect calculates the supersymmetric and Higgs particle spectrum (masses and some other relevant parameters) in the unconstrained Minimal

  4. Incidental Liver Findings in 99mTc-Sestamibi Myocardial Perfusion SPECT.

    PubMed

    De Lorenzo, Andrea; da Cruz Netto, Pedro Gomes; Pedras, Paulo de Sa Villela

    2016-03-01

    In cardiac nuclear imaging, the liver is mostly remembered as a source of artifact in the left ventricular inferior wall. However, the liver may eventually display unexpected findings, which draw attention to significant noncardiac disease. In a patient referred for myocardial perfusion SPECT to investigate atypical chest pain, focal areas of increased tracer uptake revealed intrahepatic biliary dilatation.

  5. [Clinical value of rapid clearance in resting sestamibi cardiac SPECT in patients with acute myocardial infarction].

    PubMed

    Itagane, H; Yamagishi, H; Otsuka, M; Minami, S; Suto, Y; Hato, K; Tojo, O; Okumachi, F; Haze, K

    1995-07-01

    Resting 99mTc sestamibi (MIBI) SPECT and exercise-reinjection thallium-201 (T1) SPECT were performed in fourteen patients with acute myocardial infarction (AMI). MIBI SPECT were obtained 90 min (MIBI-90) and 300 min (MIBI-300) after injection of 370 MBq of MIBI at rest. MIBI-90 and MIBI-300 were compared with exercise T1 imaging (T1-EX) and T1 reinjection imaging (REINJ). Each SPECT image was divided into 22 segments and myocardial uptake was scored visually. Abnormal perfusion defects were observed in 94 myocardial regions. Worsening of the score was observed in 79 segments (84%) on MIBI-300 compared with MIBI-90. Total MIBI-300 uptake score per person was significantly greater than that at MIBI-90 (14.8 +/- 8.6 vs. 7.7 +/- 7.9, p = 0.001). The concordance rate of defect score between MIBI-90 and REINJ was significantly higher than that between MIBI-300 and REINJ (55% vs. 17%, p = 0.001). In nine patients without recanalization of an infarct-related artery, perfusion defects were seen in 74 segments. The concordance rate of defect scores between MIBI-300 and T1-EX was significantly higher than that between MIBI-90 and T1-EX (45% vs. 16%, p = 0.001). In conclusion, rapid clearance of MIBI was observed frequently in patients with AMI. MIBI-90 and MIBI-300 may reflect myocardial viability and areas at risk for AMI, respectively.

  6. The magnetic shielding for the neutron decay spectrometer aSPECT

    NASA Astrophysics Data System (ADS)

    Konrad, Gertrud; Ayala Guardia, Fidel; Baeßler, Stefan; Borg, Michael; Glück, Ferenc; Heil, Werner; Hiebel, Stefan; Muñoz Horta, Raquel; Sobolev, Yury

    2014-12-01

    Many experiments in nuclear and neutron physics are confronted with the problem that they use a superconducting magnetic spectrometer which potentially affects other experiments by their stray magnetic field. The retardation spectrometer aSPECT consists, inter alia, of a superconducting magnet system that produces a strong longitudinal magnetic field of up to 6.2 T. In order not to disturb other experiments in the vicinity of aSPECT, we had to develop a magnetic field return yoke for the magnet system. While the return yoke must reduce the stray magnetic field, the internal magnetic field and its homogeneity should not be affected. As in many cases, the magnetic shielding for aSPECT must manage with limited space. In addition, we must ensure that the additional magnetic forces on the magnet coils are not destructive. In order to determine the most suitable geometry for the magnetic shielding for aSPECT, we simulated a variety of possible geometries and combinations of shielding materials of non-linear permeability. The results of our simulations were checked through magnetic field measurements both with Hall and nuclear magnetic resonance probes. The experimental data are in good agreement with the simulated values: the mean deviation from the simulated exterior magnetic field is (-1.7±4.8)%. However, in the two critical regions, the internal magnetic field deviates by 0.2% (decay volume) and < 1 ×10-4 (analyzing plane) from the simulated values.

  7. 5-HT radioligands for human brain imaging with PET and SPECT.

    PubMed

    Paterson, Louise M; Kornum, Birgitte R; Nutt, David J; Pike, Victor W; Knudsen, Gitte M

    2013-01-01

    The serotonergic system plays a key modulatory role in the brain and is the target for many drug treatments for brain disorders either through reuptake blockade or via interactions at the 14 subtypes of 5-HT receptors. This review provides the history and current status of radioligands used for positron emission tomography (PET) and single photon emission computerized tomography (SPECT) imaging of human brain serotonin (5-HT) receptors, the 5-HT transporter (SERT), and 5-HT synthesis rate. Currently available radioligands for in vivo brain imaging of the 5-HT system in humans include antagonists for the 5-HT(1A), 5-HT(1B), 5-HT(2A), and 5-HT(4) receptors, and for SERT. Here we describe the evolution of these radioligands, along with the attempts made to develop radioligands for additional serotonergic targets. We describe the properties needed for a radioligand to become successful and the main caveats. The success of a PET or SPECT radioligand can ultimately be assessed by its frequency of use, its utility in humans, and the number of research sites using it relative to its invention date, and so these aspects are also covered. In conclusion, the development of PET and SPECT radioligands to image serotonergic targets is of high interest, and successful evaluation in humans is leading to invaluable insight into normal and abnormal brain function, emphasizing the need for continued development of both SPECT and PET radioligands for human brain imaging.

  8. The use of spect/ct in the evaluation of heterotopic ossification in para/tetraplegics

    PubMed Central

    Lima, Maurício Coelho; Passarelli, Marcus Ceregati; Dario, Virgílio; Lebani, Bruno Rodrigues; Monteiro, Paulo Henrique Silva; Ramos, Celso Darío

    2014-01-01

    Objective: To evaluate the stage of maturation and the metabolism of neurogenic heterotopic ossification by using SPECT/CT. Methods: A total of 12 medical records of patients with spinal cord injury, all of them classified according to the ASIA protocol (disability scale from the American Spinal Injury Association) in complete lesion (A) and partial lesions (B, C and D) and registered at the Laboratory of Biomechanics and Rehabilitation of the Locomotor System, were submitted to SPECT/CT evaluation. Results: Sixteen hips with heterotopic ossification observed in X-ray were studied and only two (12.5%) had high osteoblastic activity. Five hips showed medium activity, three (18.75%) low activity and six (37.5%) did not present any activity detected by SPECT/CT. Conclusion: SPECT/CT helps to determinate which patients have a greater risk of relapse after surgical resection, proving to be a useful imaging study in preoperative evaluation that can be used to determinate the postoperative prognosis of these patients. Level of Evidence III, Investigating a Diagnostic Test. PMID:24644413

  9. The parallel implementation of a backpropagation neural network and its applicability to SPECT image reconstruction

    SciTech Connect

    Kerr, J.P.

    1992-12-31

    The objective of this study was to determine the feasibility of using an Artificial Neural Network (ANN), in particular a backpropagation ANN, to improve the speed and quality of the reconstruction of three-dimensional SPECT (single photon emission computed tomography) images. In addition, since the processing elements (PE)s in each layer of an ANN are independent of each other, the speed and efficiency of the neural network architecture could be better optimized by implementing the ANN on a massively parallel computer. The specific goals of this research were: to implement a fully interconnected backpropagation neural network on a serial computer and a SIMD parallel computer, to identify any reduction in the time required to train these networks on the parallel machine versus the serial machine, to determine if these neural networks can learn to recognize SPECT data by training them on a section of an actual SPECT image, and to determine from the knowledge obtained in this research if full SPECT image reconstruction by an ANN implemented on a parallel computer is feasible both in time required to train the network, and in quality of the images reconstructed.

  10. The parallel implementation of a backpropagation neural network and its applicability to SPECT image reconstruction

    SciTech Connect

    Kerr, J.P.

    1992-01-01

    The objective of this study was to determine the feasibility of using an Artificial Neural Network (ANN), in particular a backpropagation ANN, to improve the speed and quality of the reconstruction of three-dimensional SPECT (single photon emission computed tomography) images. In addition, since the processing elements (PE)s in each layer of an ANN are independent of each other, the speed and efficiency of the neural network architecture could be better optimized by implementing the ANN on a massively parallel computer. The specific goals of this research were: to implement a fully interconnected backpropagation neural network on a serial computer and a SIMD parallel computer, to identify any reduction in the time required to train these networks on the parallel machine versus the serial machine, to determine if these neural networks can learn to recognize SPECT data by training them on a section of an actual SPECT image, and to determine from the knowledge obtained in this research if full SPECT image reconstruction by an ANN implemented on a parallel computer is feasible both in time required to train the network, and in quality of the images reconstructed.

  11. System design and development of a pinhole SPECT system for quantitative functional imaging of small animals.

    PubMed

    Aoi, Toshiyuki; Zeniya, Tsutomu; Watabe, Hiroshi; Deloar, Hossain M; Matsuda, Tetsuya; Iida, Hidehiro

    2006-04-01

    Recently, small animal imaging by pinhole SPECT has been widely investigated by several researchers. We developed a pinhole SPECT system specially designed for small animal imaging. The system consists of a rotation unit for a small animal and a SPECT camera attached with a pinhole collimator. In order to acquire complete data of the projections, the system has two orbits with angles of 90 degrees and 45 degrees with respect to the object. In this system, the position of the SPECT camera is kept fixed, and the animal is rotated in order to avoid misalignment of the center of rotation (COR). We implemented a three dimensional OSEM algorithm for the reconstruction of data acquired by the system from both the orbitals. A point source experiment revealed no significant COR misalignment using the proposed system. Experiments with a line phantom clearly indicated that our system succeeded in minimizing the misalignment of the COR. We performed a study with a rat and 99mTc-HMDP, an agent for bone scan, and demonstrated a dramatic improvement in the spatial resolution and uniformity achieved by our system in comparison with the conventional Feldkamp algorithm with one set of orbital data.

  12. Joint reconstruction of activity and attenuation map using LM SPECT emission data

    NASA Astrophysics Data System (ADS)

    Jha, Abhinav K.; Clarkson, Eric; Kupinski, Matthew A.; Barrett, Harrison H.

    2013-03-01

    Attenuation and scatter correction in single photon emission computed tomography (SPECT) imaging often requires a computed tomography (CT) scan to compute the attenuation map of the patient. This results in increased radiation dose for the patient, and also has other disadvantages such as increased costs and hardware complexity. Attenuation in SPECT is a direct consequence of Compton scattering, and therefore, if the scattered photon data can give information about the attenuation map, then the CT scan may not be required. In this paper, we investigate the possibility of joint reconstruction of the activity and attenuation map using list- mode (LM) SPECT emission data, including the scattered-photon data. We propose a path-based formalism to process scattered-photon data. Following this, we derive analytic expressions to compute the Craḿer-Rao bound (CRB) of the activity and attenuation map estimates, using which, we can explore the fundamental limit of information-retrieval capacity from LM SPECT emission data. We then suggest a maximum-likelihood (ML) scheme that uses the LM emission data to jointly reconstruct the activity and attenuation map. We also propose an expectation-maximization (EM) algorithm to compute the ML solution.

  13. The Proton Spectrum in Neutron Beta Decay: First Results with the aSPECT spectrometer

    NASA Astrophysics Data System (ADS)

    Baeßler, S.; Angerer, H.; Ayala Guardia, F.; Borg, M.; Eberhardt, K.; Glück, F.; Heil, W.; Konorov, I.; Konrad, G.; Luquero Llopis, N.; Muñoz Horta, R.; Orlowski, M.; Petzoldt, G.; Rich, D.; Simson, M.; Sobolev, Y.; Wirth, H. F.; Zimmer, O.

    2006-11-01

    First measurements with the aSPECT spectrometer have been performed in a beam time at the beam line MEPHISTO of the neutron research reactor FRM-II. In this paper we give a short description of the spectrometer. The data analysis is still underway.

  14. A restraint-free small animal SPECT imaging system with motion tracking

    SciTech Connect

    Weisenberger, A.G.; Gleason, S.S.; Goddard, J.; Kross, B.; Majewski, S.; Meikle, S.R.; Paulus, M.J.; Pomper, M.; Popov, V.; Smith, M.F.; Welch, B.L.; Wojcik, R.

    2005-06-01

    We report on an approach toward the development of a high-resolution single photon emission computed tomography (SPECT) system to image the biodistribution of radiolabeled tracers such as Tc-99m and I-125 in unrestrained/unanesthetized mice. An infrared (IR)-based position tracking apparatus has been developed and integrated into a SPECT gantry. The tracking system is designed to measure the spatial position of a mouse's head at a rate of 10-15 frames per second with submillimeter accuracy. The high-resolution, gamma imaging detectors are based on pixellated NaI(Tl) crystal scintillator arrays, position-sensitive photomultiplier tubes, and novel readout circuitry requiring fewer analog-digital converter (ADC) channels while retaining high spatial resolution. Two SPECT gamma camera detector heads based upon position-sensitive photomultiplier tubes have been built and installed onto the gantry. The IR landmark-based pose measurement and tracking system is under development to provide animal position data during a SPECT scan. The animal position and orientation data acquired by the tracking system will be used for motion correction during the tomographic image reconstruction.

  15. Findings of 123I-iomazenil SPECT during and after stroke-like episodes in a patient with MELAS.

    PubMed

    Taguchi, Yoshiharu; Takashima, Shutaro; Noguchi, Kyo; Tanaka, Kortaro

    2014-06-01

    Reduced cortical benzodiazepine receptor binding potential in late images of I-iomazenil SPECT indicates neuronal damage in the cortex. We present the case of a 31-year-old woman with mitochondrial myopathy, encephalopathy, lactic acidosis, and stroke-like episodes (MELAS) who had focal seizures in the right hand. FLAIR imaging in the ictal state revealed a high-intensity lesion in the left post-central gyrus, while I-iomazenil SPECT showed decreased tracer uptake in this lesion. The lesion completely disappeared on FLAIR imaging performed 1 month after the focal seizures; in contrast, I-iomazenil SPECT still revealed a significant decrease in tracer uptake in this lesion.

  16. Segmented slant hole collimator for stationary cardiac SPECT: Monte Carlo simulations

    PubMed Central

    Mao, Yanfei; Yu, Zhicong; Zeng, Gengsheng L.

    2015-01-01

    Purpose: This work is a preliminary study of a stationary cardiac SPECT system. The goal of this research is to propose a stationary cardiac SPECT system using segmented slant-hole collimators and to perform computer simulations to test the feasibility. Compared to the rotational SPECT, a stationary system has a benefit of acquiring temporally consistent projections. The most challenging issue in building a stationary system is to provide sufficient projection view-angles. Methods: A gate (geant4 application for tomographic emission) Monte Carlo model was developed to simulate a two-detector stationary cardiac SPECT that uses segmented slant-hole collimators. Each detector contains seven segmented slant-hole sections that slant to a common volume at the rotation center. Consequently, 14 view-angles over 180° were acquired without any gantry rotation. The NCAT phantom was used for data generation and a tailored maximum-likelihood expectation-maximization algorithm was used for image reconstruction. Effects of limited number of view-angles and data truncation were carefully evaluated in the paper. Results: Simulation results indicated that the proposed segmented slant-hole stationary cardiac SPECT system is able to acquire sufficient data for cardiac imaging without a loss of image quality, even when the uptakes in the liver and kidneys are high. Seven views are acquired simultaneously at each detector, leading to 5-fold sensitivity gain over the conventional dual-head system at the same total acquisition time, which in turn increases the signal-to-noise ratio by 19%. The segmented slant-hole SPECT system also showed a good performance in lesion detection. In our prototype system, a short hole-length was used to reduce the dead zone between neighboring collimator segments. The measured sensitivity gain is about 17-fold over the conventional dual-head system. Conclusions: The gate Monte Carlo simulations confirm the feasibility of the proposed stationary cardiac

  17. Fast 3D iterative image reconstruction for SPECT with rotating slat collimators

    NASA Astrophysics Data System (ADS)

    Van Holen, Roel; Vandenberghe, Stefaan; Staelens, Steven; DeBeenhouwer, Jan; Lemahieu, Ignace

    2009-02-01

    As an alternative to the use of traditional parallel hole collimators, SPECT imaging can be performed using rotating slat collimators. While maintaining the spatial resolution, a gain in image quality could be expected from the higher photon collection efficiency of this type of collimator. However, the use of iterative methods to do fully three-dimensional (3D) reconstruction is computationally much more expensive and furthermore involves slow convergence compared to a classical SPECT reconstruction. It has been proposed to do 3D reconstruction by splitting the system matrix into two separate matrices, forcing the reconstruction to first estimate the sinograms from the rotating slat SPECT data before estimating the image. While alleviating the computational load by one order of magnitude, this split matrix approach would result in fast computation of the projections in an iterative algorithm, but does not solve the problem of slow convergence. There is thus a need for an algorithm which speeds up convergence while maintaining image quality for rotating slat collimated SPECT cameras. Therefore, we developed a reconstruction algorithm based on the split matrix approach which allows both a fast calculation of the forward and backward projection and a fast convergence. In this work, an algorithm of the maximum likelihood expectation maximization (MLEM) type, obtained from a split system matrix MLEM reconstruction, is proposed as a reconstruction method for rotating slat collimated SPECT data. Here, we compare this new algorithm to the conventional split system matrix MLEM method and to a gold standard fully 3D MLEM reconstruction algorithm on the basis of computational load, convergence and contrast-to-noise. Furthermore, ordered subsets expectation maximization (OSEM) implementations of these three algorithms are compared. Calculation of computational load and convergence for the different algorithms shows a speedup for the new method of 38 and 426 compared to the

  18. A clinical role for 99mTc-HMPAO SPECT in the investigation of dementia?

    PubMed Central

    Talbot, P.; Lloyd, J.; Snowden, J.; Neary, D.; Testa, H.

    1998-01-01

    OBJECTIVES—To provide the clinician with a guide to the clinical utility of 99mTc-HMPAO single photon emission computed tomography (SPECT) and to the interpretation of specific test results in the differential diagnosis of dementia.
METHODS—Three hundred and sixty three patients with dementia were studied prospectively for a median three (range 1-6) years and classified into disease groups on the basis of established clinical criteria. The degree to which different patterns of cerebral blood flow (CBF) abnormality found on 99mTc-HMPAO SPECT imaging at the time of initial patient presentation modified clinical diagnoses was determined by calculating the likelihood ratios for pairwise disease group comparisons. The optimal clinical usage of 99mTc-HMPAO SPECT was determined by calculating the percentage of significant test results for each pairwise disease group comparison.
RESULTS—Bilateral posterior CBF abnormality was found to significantly increase the odds of a patient having Alzheimer's disease as opposed to vascular dementia or frontotemporal dementia. Bilateral anterior CBF abnormality significantly increased the odds of a patient having frontotemporal dementia as opposed to Alzheimer's disease, vascular dementia, or Lewy body disease. "Patchy" CBF changes significantly increased the odds of a patient having vascular dementia as opposed to Alzheimer's disease. Unilateral anterior, unilateral anterior plus unilateral posterior, and generalised CBF abnormality failed to contribute to the differentiation of any of these forms of dementia.
CONCLUSIONS—99mTc-HMPAO SPECT was found to be most useful in distinguishing Alzheimer's disease from vascular dementia and fronto temporal dementia, and least useful in differentiating between Alzheimer's disease and Lewy body disease, and between vascular dementia, frontotemporal dementia, and progressive aphasia. It is suggested that CBF SPECT should be used selectively and as an adjunct to clinical evaluation

  19. [Development of a Novel Body Phantom with Bone Equivalent Density for Evaluation of Bone SPECT].

    PubMed

    Ichikawa, Hajime; Miwa, Kenta; Matsutomo, Norikazu; Watanabe, Yoichi; Kato, Toyohiro; Shimada, Hideki

    2015-12-01

    We developed a custom-designed phantom for bone single photon emission computed tomography (SPECT)-specific radioactivity distribution and linear attenuation coefficient. The aim of this study was to evaluate the accuracy of the phantom. The lumbar phantom consisted of the trunk of a body phantom (background) containing a cylinder (vertebral body), a sphere (tumor), and a T-shaped container (processus). The vertebral body, tumor, and processus phantoms contained a K(2)HPO(4) solution of bone equivalent density and 50, 300 and 50 kBq/mL of (99m)Tc, respectively. The body phantom contained 8 kBq/mL of (99m)Tc solution. SPECT images were acquired using low-energy high-resolution collimation, a 128 × 128 matrix and 120 projections over 360° with a dwell time of 15 sec/view × 4 times. Thereafter, CT images were acquired at 130 kV and 70 ref mAs using adaptive dose modulation. The SPECT data were reconstructed with ordered subset expectation maximization with three-dimensional, scatter, and CT-based attenuation correction. Count ratio, linear attenuation coefficient (LAC), and full-width at half-maximum (FWHM) were measured. Count ratios between the background, the vertebral body, and the tumor in SPECT images were 463.8: 2888.0: 15150.3 (1: 6.23: 32.7). The LAC of the background and vertebral body in the CT-derived attenuation map were 0.155 cm⁻¹ and 0.284 cm⁻¹, respectively, and the FWHM measured from the processus was 15.27 mm. The precise counts and LAC indicated that the phantom was accurate and could serve as a tool for evaluating acquisition, reconstruction parameters, and quantitation in bone SPECT images. PMID:26685836

  20. Voxel-by-voxel analysis of brain SPECT perfusion in Fibromyalgia

    NASA Astrophysics Data System (ADS)

    Guedj, Eric; Taïeb, David; Cammilleri, Serge; Lussato, David; de Laforte, Catherine; Niboyet, Jean; Mundler, Olivier

    2007-02-01

    We evaluated brain perfusion SPECT at rest, without noxious stiumuli, in a homogeneous group of hyperalgesic FM patients. We performed a voxel-based analysis in comparison to a control group, matched for age and gender. Under such conditions, we made the assumption that significant cerebral perfusion abnormalities could be demonstrated, evidencing altered cerebral processing associated with spontaneous pain in FM patients. The secondary objective was to study the reversibility and the prognostic value of such possible perfusion abnormalities under specific treatment. Eighteen hyperalgesic FM women (mean age 48 yr; range 25-63 yr; ACR criteria) and 10 healthy women matched for age were enrolled in the study. A voxel-by-voxel group analysis was performed using SPM2 ( p<0.05, corrected for multiple comparisons). All brain SPECT were performed before any change was made in therapy in the pain care unit. A second SPECT was performed a month later after specific treatment by Ketamine. Compared to control subjects, we observed individual brain SPECT abnormalities in FM patients, confirmed by SPM2 analysis with hyperperfusion of the somatosensory cortex and hypoperfusion of the frontal, cingulate, medial temporal and cerebellar cortices. We also found that a medial frontal and anterior cingulate hypoperfusions were highly predictive (PPV=83%; NPV=91%) of non-response on Ketamine, and that only responders showed significant modification of brain perfusion, after treatment. In the present study performed without noxious stimuli in hyperalgesic FM patients, we found significant hyperperfusion in regions of the brain known to be involved in sensory dimension of pain processing and significant hypoperfusion in areas assumed to be associated with the affective dimension. As current pharmacological and non-pharmacological therapies act differently on both components of pain, we hypothesize that SPECT could be a valuable and readily available tool to guide individual therapeutic

  1. Monte Carlo methods for the simulation of positron emitters in SPECT systems

    SciTech Connect

    Dobrzeniecki, A.B.; Selcow, E.C.; Yanch, J.C.; Belanger, M.J.; Lu, A.; Esser, P.D.

    1996-12-31

    Monte Carlo simulations of nuclear medical systems are being widely used to better understand the characteristics of the acquired images. Single-photon emission computed tomography (SPECT) is an imaging modality that provides a physician with a nuclear medical image of function in an organ. In SPECT systems, the patient is injected with a radiopharmaceutical that is labeled with a photon-emitting radioisotope. A collimated gamma camera revolves around the patient, providing a series of planar images, which are then reconstructed to produce a three-dimensional image of the radiotracer distribution in the patient or phantom. The usage of positron emission computed tomography (PET) systems with {sup 18}F-labeled fluorodeoxyglucose (FDG) is an important mechanism for quantitating tumor glucose metabolism. This may facilitate the detection of primary and metastatic malignancies and the distinction between tissue regions that are normal, fibrous, necrotic, or cancerous. However, PET facilities are implemented in significantly fewer hospitals in the United States than SPECT systems. To address this issue and provide similar functional information to a clinician, there is a growing interest in imaging the 511-keV photons associated with PET agents in SPECT imaging systems. Note that the clinical utility of FDG as a diagnostic radiopharmaceutical cannot be replicated by known radiotracers emitting single photons. The authors are extending their simulations of SPECT systems to higher photon energies, where at present there is more disagreement between simulations and actual data. They discuss here possible reasons for this and steps being taken to address this discrepancy in the development of the modeling.

  2. Performance of Myocardial Perfusion Imaging Using Multi-focus Fan Beam Collimator with Resolution Recovery Reconstruction in a Comparison with Conventional SPECT

    PubMed Central

    Matsutomo, Norikazu; Nagaki, Akio; Sasaki, Masayuki

    2014-01-01

    Objective(s): IQ-SPECT is an advanced high-speed SPECT modality for myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQ-SPECT with conventional SPECT in terms of performance, based on standard clinical protocols. In addition, we examined the concordance between conventional and IQ_SPECT in patients with coronary artery disease (CAD). Methods: Fifty-three patients, undergoing rest-gated MPI for the evaluation of known or suspected CAD, were enrolled in this study. In each patient, conventional SPECT (99mTc-tetrofosmin, 9.6 min and 201Tl, 12.9 min) was performed, immediately followed by IQ-SPECT, using a short acquisition time (4.3 min for 99mTc-tetrofosmin and 6.2 min for 201Tl). A quantitative analysis was performed on an MPI polar map, using a 20-segment model of the left ventricle. An automated analysis by gated SPECT was carried out to determine the left ventricular volume and function including end-diastolic volume (EDV), end-systolic volume (ESV), and left ventricular ejection fraction (LVEF). The degree of concordance between conventional SPECT and IQ-SPECT images was evaluated according to linear regression and Bland-Altman analyses. Results: The segmental percent uptake exhibited a significant correlation between IQ-SPECT and conventional SPECT (P<0.05). The mean differences in 99mTc-tetrofosmin studies were 1.1±6.6% (apex), 2.8±5.7% (anterior wall), 2.9±6.2% (septal wall), 4.9±6.7% (lateral wall), and 1.8±5.6% (inferior wall). Meanwhile, regarding the 201Tl-SPECT studies, these values were 1.6±6.9%, 2.0±6.6%, 2.1±5.9%, 3.3±7.2%, and 2.4±5.8%, respectively. Although the mean LVEF in IQ-SPECT tended to be higher than that observed in conventional SPECT (conventional SPECT=64.8±11.8% and IQ-SPECT=68.3±12.1% for 99mTc-tetrofosmin; conventional SPECT= 56.0±11.7% and IQ-SPECT=61.5±12.2% for 201Tl), quantitative parameters were not

  3. Development and validation of technique for in-vivo 3D analysis of cranial bone graft survival

    NASA Astrophysics Data System (ADS)

    Bernstein, Mark P.; Caldwell, Curtis B.; Antonyshyn, Oleh M.; Ma, Karen; Cooper, Perry W.; Ehrlich, Lisa E.

    1997-05-01

    Bone autografts are routinely employed in the reconstruction of facial deformities resulting from trauma, tumor ablation or congenital malformations. The combined use of post- operative 3D CT and SPECT imaging provides a means for quantitative in vivo evaluation of bone graft volume and osteoblastic activity. The specific objectives of this study were: (1) Determine the reliability and accuracy of interactive computer-assisted analysis of bone graft volumes based on 3D CT scans; (2) Determine the error in CT/SPECT multimodality image registration; (3) Determine the error in SPECT/SPECT image registration; and (4) Determine the reliability and accuracy of CT-guided SPECT uptake measurements in cranial bone grafts. Five human cadaver heads served as anthropomorphic models for all experiments. Four cranial defects were created in each specimen with inlay and onlay split skull bone grafts and reconstructed to skull and malar recipient sites. To acquire all images, each specimen was CT scanned and coated with Technetium doped paint. For purposes of validation, skulls were landmarked with 1/16-inch ball-bearings and Indium. This study provides a new technique relating anatomy and physiology for the analysis of cranial bone graft survival.

  4. Comparison of 18F SPECT with PET in myocardial imaging: A realistic thorax-cardiac phantom study

    PubMed Central

    Knešaurek, Karin; Machac, Josef

    2006-01-01

    Background Positron emission tomography (PET) imaging with fluorine-18 (18F) Fluorodeoxyglucose (FDG) and flow tracer such as Rubidium-82 (82Rb) is an established method for evaluating an ischemic but viable myocardium. However, the high cost of PET imaging restricts its wider clinical use. Therefore, less expensive 18F FDG single photon emission computed tomography (SPECT) imaging has been considered as an alternative to 18F FDG PET imaging. The purpose of the work is to compare SPECT with PET in myocardial perfusion/viability imaging. Methods A nonuniform RH-2 thorax-heart phantom was used in the SPECT and PET acquisitions. Three inserts, 3 cm, 2 cm and 1 cm in diameter, were placed in the left ventricular (LV) wall to simulate infarcts. The phantom acquisition was performed sequentially with 7.4 MBq of 18F and 22.2 MBq of Technetium-99m (99mTc) in the SPECT study and with 7.4 MBq of 18F and 370 MBq of 82Rb in the PET study. SPECT and PET data were processed using standard reconstruction software provided by vendors. Circumferential profiles of the short-axis slices, the contrast and viability of the inserts were used to evaluate the SPECT and PET images. Results The contrast for 3 cm, 2 cm and 1 cm inserts were for 18F PET data, 1.0 ± 0.01, 0.67 ± 0.02 and 0.25 ± 0.01, respectively. For 82Rb PET data, the corresponding contrast values were 0.61 ± 0.02, 0.37 ± 0.02 and 0.19 ± 0.01, respectively. For 18F SPECT the contrast values were, 0.31 ± 0.03 and 0.20 ± 0.05 for 3 cm and 2 cm inserts, respectively. For 99mTc SPECT the contrast values were, 0.63 ± 0.04 and 0.24 ± 0.05 for 3 cm and 2 cm inserts respectively. In SPECT, the 1 cm insert was not detectable. In the SPECT study, all three inserts were falsely diagnosed as "viable", while in the PET study, only the 1 cm insert was diagnosed falsely "viable". Conclusion For smaller defects the 99mTc/18F SPECT imaging cannot entirely replace the more expensive 82Rb/18F PET for myocardial perfusion

  5. Comparison of SPECT/CT, MRI and CT in diagnosis of skull base bone invasion in nasopharyngeal carcinoma.

    PubMed

    Zhang, Shu-xu; Han, Peng-hui; Zhang, Guo-qian; Wang, Rui-hao; Ge, Yong-bin; Ren, Zhi-gang; Li, Jian-sheng; Fu, Wen-hai

    2014-01-01

    Early detection of skull base invasion in nasopharyngeal carcinoma (NPC) is crucial for correct staging, assessing treatment response and contouring the tumor target in radiotherapy planning, as well as improving the patient's prognosis. To compare the diagnostic efficacy of single photon emission computed tomography/computed tomography (SPECT/CT) imaging, magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of skull base invasion in NPC. Sixty untreated patients with histologically proven NPC underwent SPECT/CT imaging, contrast-enhanced MRI and CT. Of the 60 patients, 30 had skull base invasion confirmed by the final results of contrast-enhanced MRI, CT and six-month follow-up imaging (MRI and CT). The diagnostic efficacy of the three imaging modalities in detecting skull base invasion was evaluated. The rates of positive findings of skull base invasion for SPECT/CT, MRI and CT were 53.3%, 48.3% and 33.3%, respectively. The sensitivity, specificity and accuracy were 93.3%, 86.7% and 90.0% for SPECT/CT fusion imaging, 96.7%, 100.0% and 98.3% for contrast-enhanced MRI, and 66.7%, 100.0% and 83.3% for contrast-enhanced CT. MRI showed the best performance for the diagnosis of skull base invasion in nasopharyngeal carcinoma, followed closely by SPECT/CT. SPECT/CT had poorer specificity than that of both MRI and CT, while CT had the lowest sensitivity.

  6. Comparative study of diverse model building strategies for 3D-ASM segmentation of dynamic gated SPECT data

    NASA Astrophysics Data System (ADS)

    Tobon-Gomez, C.; Butakoff, C.; Ordas, S.; Aguade, S.; Frangi, A. F.

    2007-03-01

    Over the course of the last two decades, myocardial perfusion with Single Photon Emission Computed Tomography (SPECT) has emerged as an established and well-validated method for assessing myocardial ischemia, viability, and function. Gated-SPECT imaging integrates traditional perfusion information along with global left ventricular function. Despite of these advantages, inherent limitations of SPECT imaging yield a challenging segmentation problem, since an error of only one voxel along the chamber surface may generate a huge difference in volume calculation. In previous works we implemented a 3-D statistical model-based algorithm for Left Ventricle (LV) segmentation of in dynamic perfusion SPECT studies. The present work evaluates the relevance of training a different Active Shape Model (ASM) for each frame of the gated SPECT imaging acquisition in terms of their subsequent segmentation accuracy. Models are subsequently employed to segment the LV cavity of gated SPECT studies of a virtual population. The evaluation is accomplished by comparing point-to-surface (P2S) and volume errors, both against a proper Gold Standard. The dataset comprised 40 voxel phantoms (NCAT, Johns Hopkins, University of of North Carolina). Monte-Carlo simulations were generated with SIMIND (Lund University) and reconstructed to tomographic slices with ASPIRE (University of Michigan).

  7. [Artifactual defect of inferior myocardium on 123I-metaiodobenzylguanidine myocardial SPECT: characteristic findings and preventive method on phantom study].

    PubMed

    Kobayashi, H; Terada, S; Kanaya, S; Kashikura, K; Momose, M; Hosoda, S; Kusakabe, K

    1994-04-01

    Discordance between planar and SPECT image of inferior myocardial defect on 123I-metaiodobenzylguanidine myocardial scintigraphy (MIBG) was occasionally observed in the clinical studies. The purpose of this study is to clarify the existence of artifactual myocardial defect on MIBG SPECT image. Phantom study was performed in various kinds of situation using triple gamma camera. Artifactual defect adjacent to the liver was significantly observed in the case of increased liver/heart uptake ratio more than 2:1. Artifactual defect was markedly observed in the 180 degrees than that in the 360 degrees SPECT acquisition. To avoid artifactual defect during SPECT acquisition, liver phantom was moved down to the foot direction (vanishing liver position). In this phantom position, artifactual defect adjacent to the liver was not observed on reconstructed myocardial SPECT image. The vanishing liver position was also applicable to human study. Human body was inclined to right side at an angle of 15 degrees, artifactual defect could be avoided. Further study is needed to analyze the cause of this artifactual defect and to conform the preventive method with vanishing liver position in the routine myocardial SPECT examination.

  8. Is there a Role for Spect with 99mTc-Tetrofosmin in the Diagnostic Work Up of a Brain Tumor?

    PubMed Central

    BIRBILIS, Theodossios; BOUSSIOS, Nikolaos; PAPATHEODOSSIOU, Lazaros; MATIS, Georgios; ZISSIMOPOULOS, Athanassios

    2013-01-01

    ABSTRACT Brain MRI is the gold standard for diagnosis of brain tumors. In some cases preoperative MRI cannot predict the grade of malignancy, diagnostic information that could be very helpful to the surgeon. In such cases functional imaging with nuclear medicine techniques may prove quite useful. We present a case of a 58-year-old man with a brain tumor in the parieto-occipital region. Anatomic brain imaging by magnetic resonance imaging was indicative of a low grade astrocytoma. This was followed by planar imaging and single-photon emission computed tomography (SPECT) with 99mTc-tetrofosmin which showed increased radiotracer accumulation in the lesion, suggesting a glioblastoma which was histologically confirmed. We think that in the MRI era sometimes a 99mTc-tetrofosmin brain scan can contribute to diagnostic workup and improve the final management of the patient. PMID:24790666

  9. Quantitative reconstruction for myocardial perfusion SPECT: an efficient approach by depth-dependent deconvolution and matrix rotation.

    PubMed

    Ye, J; Liang, Z; Harrington, D P

    1994-08-01

    An efficient reconstruction method for myocardial perfusion single-photon emission computed tomography (SPECT) has been developed which compensates simultaneously for attenuation, scatter, and resolution variation. The scattered photons in the primary-energy-window measurements are approximately removed by subtracting the weighted scatter-energy-window samples. The resolution variation is corrected by deconvolving the subtracted data with the detector-response kernel in frequency space using the depth-dependent frequency relation. The attenuated photons are compensated by recursively tracing the attenuation factors through the object-specific attenuation map. An experimental chest phantom with defects inside myocardium was used to test the method. The attenuation map of the phantom was reconstructed from transmission scans using a flat external source and a high-resolution parallel-hole collimator of a single-detector system. The detector-response kernel was approximated from measurements of a point source in air at several depths from the collimator surface. The emission data were acquired by the same detector setting. A computer simulation using similar protocols as in the experiment was performed. Both the simulation and experiment showed significant improvement in quantification with the proposed method, as compared to the conventional filtered-backprojection technique. The quantitative gain by the additional deconvolution was demonstrated. The computation time was less than 20 min on a HP/730 desktop computer for reconstruction of a 1282 x 64 array from 128 projections of 128 x 64 samples. PMID:15551566

  10. Ictal and interictal 99mTc-HMPAO brain SPECT of a MELAS case presented with epilepsy-like visual hallucination.

    PubMed

    Wei, Cheng-Yu; Hsiao, Heng-Long; Chen, Shang-Chi; Hung, Guang-Uei; Kao, Chia-Hung

    2012-09-01

    A 55-year-old woman was diagnosed with the syndrome of mitochondrial myopathy, encephalopathy, lactic acidosis, and stroke-like episodes (MELAS). She was referred for Tc-HMPAO brain SPECT because of visual hallucinations, which were suspected to be related to epileptic seizures. Ictal SPECT images showed remarkable hyperperfusion in the left occipital cortex, which returned to near-normal status on the interictal SPECT images after treatment with anticonvulsants. It is very rare to see such an ictal SPECT image of epileptic or epilepsy-like disorders, especially in the setting of MELAS syndrome with visual hallucination.

  11. SU-E-I-20: Dead Time Count Loss Compensation in SPECT/CT: Projection Versus Global Correction

    SciTech Connect

    Siman, W; Kappadath, S

    2014-06-01

    Purpose: To compare projection-based versus global correction that compensate for deadtime count loss in SPECT/CT images. Methods: SPECT/CT images of an IEC phantom (2.3GBq 99mTc) with ∼10% deadtime loss containing the 37mm (uptake 3), 28 and 22mm (uptake 6) spheres were acquired using a 2 detector SPECT/CT system with 64 projections/detector and 15 s/projection. The deadtime, Ti and the true count rate, Ni at each projection, i was calculated using the monitor-source method. Deadtime corrected SPECT were reconstructed twice: (1) with projections that were individually-corrected for deadtime-losses; and (2) with original projections with losses and then correcting the reconstructed SPECT images using a scaling factor equal to the inverse of the average fractional loss for 5 projections/detector. For both cases, the SPECT images were reconstructed using OSEM with attenuation and scatter corrections. The two SPECT datasets were assessed by comparing line profiles in xyplane and z-axis, evaluating the count recoveries, and comparing ROI statistics. Higher deadtime losses (up to 50%) were also simulated to the individually corrected projections by multiplying each projection i by exp(-a*Ni*Ti), where a is a scalar. Additionally, deadtime corrections in phantoms with different geometries and deadtime losses were also explored. The same two correction methods were carried for all these data sets. Results: Averaging the deadtime losses in 5 projections/detector suffices to recover >99% of the loss counts in most clinical cases. The line profiles (xyplane and z-axis) and the statistics in the ROIs drawn in the SPECT images corrected using both methods showed agreement within the statistical noise. The count-loss recoveries in the two methods also agree within >99%. Conclusion: The projection-based and the global correction yield visually indistinguishable SPECT images. The global correction based on sparse sampling of projections losses allows for accurate SPECT deadtime

  12. Application of polarization for optical motion-registered SPECT functional imaging of tumors in mice

    NASA Astrophysics Data System (ADS)

    Baba, Justin S.; Gleason, Shaun S.; Goddard, James S.; Paulus, Michael J.

    2005-03-01

    The use of small animal models to investigate human diseases is an integral part of the development of new diagnostic and treatment regimens. Consequently, functional imaging modalities such as single photon emission computed tomography (SPECT) are increasingly being utilized to streamline the screening of animal phenotypes and to monitor disease states, progressions, and therapies. This paper focuses on the utilization of polarization filtering to minimize specular reflection from a glass tube used for holding live human-tumor-mice during functional imaging in a dedicated small animal SPECT system. The system presented is potentially useful for the real-time non-invasive investigation of diseases, such as cancer, and drug therapies in small animals because it utilizes optical motion-registered functional imaging that minimizes the effects of motion artifacts.

  13. SPECT measurements with /sup 99m/Tc-HM-PAO in focal epilepsy

    SciTech Connect

    Ryding, E.; Rosen, I.; Elmqvist, D.; Ingvar, D.H.

    1988-12-01

    The ability of SPECT measurements with (/sup 99m/Tc)-HM-PAO (Ceretec) to find the location of the epileptic focus was studied in patients under consideration for neurosurgical treatment for therapy-resistant focal epilepsy. The location of low (/sup 99m/Tc)-HM-PAO uptake regions found at interictal measurements, and of high (/sup 99m/Tc)-HM-PAO uptake regions found at ictal measurements, was compared to the findings of extensive ictal and interictal EEG examinations, and to the results of CT and MRT. While EEG revealed focal epileptic activity in all of the 14 patients, SPECT showed regional abnormalities in 13 (93%). CT and MRT showed abnormal findings in 30%.

  14. Parallel OSEM Reconstruction Algorithm for Fully 3-D SPECT on a Beowulf Cluster.

    PubMed

    Rong, Zhou; Tianyu, Ma; Yongjie, Jin

    2005-01-01

    In order to improve the computation speed of ordered subset expectation maximization (OSEM) algorithm for fully 3-D single photon emission computed tomography (SPECT) reconstruction, an experimental beowulf-type cluster was built and several parallel reconstruction schemes were described. We implemented a single-program-multiple-data (SPMD) parallel 3-D OSEM reconstruction algorithm based on message passing interface (MPI) and tested it with combinations of different number of calculating processors and different size of voxel grid in reconstruction (64×64×64 and 128×128×128). Performance of parallelization was evaluated in terms of the speedup factor and parallel efficiency. This parallel implementation methodology is expected to be helpful to make fully 3-D OSEM algorithms more feasible in clinical SPECT studies.

  15. Towards adapting a normal patient database for SPECT brain perfusion imaging

    NASA Astrophysics Data System (ADS)

    Smith, N. D.; Holmes, R. B.; Soleimani, M.; Evans, M. J.; Cade, S. C.; Mitchell, C. N.

    2012-06-01

    Single-photon emission computerized tomography (SPECT) is a tool which can be used to image perfusion in the brain. Clinicians can use such images to help diagnose dementias such as Alzheimer's disease. Due to the intrinsic stochasticity in the photon imaging system, some form of statistical comparison of an individual image with a 'normal' patient database gives a clinician additional confidence in interpreting the image. Due to the variations between SPECT camera systems, ideally a normal patient database is required for each individual system. However, cost or ethical considerations often prohibit the collection of such a database for each new camera system. Some method of adapting existing normal patient databases to new camera systems would be beneficial. This paper introduces a method which may be regarded as a 'first-pass' attempt based on 2-norm regularization and a codebook of discrete spatially stationary convolutional kernels. Some preliminary illustrative results are presented, together with discussion on limitations and possible improvements.

  16. SPECT bone scintigraphy in the diagnosis and management of mandibular condylar hyperplasia.

    PubMed

    Hodder, S C; Rees, J I; Oliver, T B; Facey, P E; Sugar, A W

    2000-04-01

    Isotope bone scans have been used for a number of years to assess growth activity in the mandibular condyle in patients who present with facial asymmetry. The aim is to distinguish normal bone growth within the condyle from increased activity that may be the cause of the asymmetry. Previous studies have, however, relied only on planar images. SPECT (single photon emission computed tomography) has been used with quantitative assessments of one mandibular condyle to clivus or lumbar spine, but we have compared one condyle with the other, which is more sensitive and accurate in detecting abnormal activity. A relative percentage uptake of 55% or more in the affected mandibular condyle is considered to be abnormal, and this has been validated by comparison with an age-matched control group. We have used SPECT as an aid to diagnosis and treatment in 18 patients with asymmetrical growth and have constructed a therapeutic algorithm to aid the treatment of these patients. PMID:10864700

  17. Characterization of a high-purity germanium detector for small-animal SPECT.

    PubMed

    Johnson, Lindsay C; Campbell, Desmond L; Hull, Ethan L; Peterson, Todd E

    2011-09-21

    We present an initial evaluation of a mechanically cooled, high-purity germanium double-sided strip detector as a potential gamma camera for small-animal SPECT. It is 90 mm in diameter and 10 mm thick with two sets of 16 orthogonal strips that have a 4.5 mm width with a 5 mm pitch. We found an energy resolution of 0.96% at 140 keV, an intrinsic efficiency of 43.3% at 122 keV and a FWHM spatial resolution of approximately 1.5 mm. We demonstrated depth-of-interaction estimation capability through comparison of pinhole acquisitions with a point source on and off axes. Finally, a flood-corrected flood image exhibited a strip-level uniformity of less than 1%. This high-purity germanium offers many desirable properties for small-animal SPECT.

  18. Information gain from count corrections in SPECT image reconstruction and classification

    SciTech Connect

    Shao, L. . Dept. of Radiology); Hero, A.O. . Dept. of Electrical Engineering and Computer Science); Rogers, W.L.; Clinthorne, N.H. . Div. of Nuclear Medicine)

    1990-04-01

    The authors present a method for quantifying the impact of count correction side information on the capability of a SPECT projective tomography system to perform image (emitter) reconstruction and feature classification. The method involves computing the image or feature related information gain which results from the presence of count correction side information at the detector. For image reconstruction this information gain is computed using Shannon's mutual information (MI), while for feature classification the authors use the cut-off rate of the SPECT information channel. For reconstruction the gain is proportional to the information divergence between the spatially dependent probability of deletion of a {gamma}-ray originating at a particular emitter location and the spatially independent average deletion probability. For classification the gain is proportional to the difference between the arithmetic mean and the geometric mean of the average number of {gamma}-ray deletions for each of the image classes. Results of analysis and numerical study are presented.

  19. Breast cancer patient with an uncommon lymphatic drainage evidenced by SPECT/CT.

    PubMed

    Groheux, David; Ferré, Romuald; Rubello, Domenico; Vercellino, Laetitia; Hindié, Elif

    2014-02-01

    SPECT/CT reinforces the role of lymphoscintigraphy in breast cancer by solving some cases with difficult reading on planar scintigraphy. An 80-year-old woman was referred to our institution for management of a screen-detected, nonpalpable, invasive lobular carcinoma of lower inner quadrant of the left breast. Lymphoscintigraphy was performed before surgery. Planar images showed an axillary sentinel node and 2 medially located hot spots. SPECT/CT allowed determining that one of the extra-axillary drainage sites was to the internal mammary basin, while the second corresponded to a mediastinal lymph node. Although this drainage was unexpected, mediastinum is a common site of breast cancer recurrence. PMID:23797233

  20. Molecular imaging of small animals with a triple-head SPECT system using pinhole collimation.

    PubMed

    Metzler, S D; Jaszczak, R J; Patil, N H; Vemulapalli, S; Akabani, G; Chin, B B

    2005-07-01

    Pinhole collimation yields high sensitivity when the distance from the object to the aperture is small, as in the case of imaging small animals. Fine-resolution images may be obtained when the magnification is large since this mitigates the effect of detector resolution. Large magnifications in pinhole single-photon emission computed tomography (SPECT) may be obtained by using a collimator whose focal length is many times the radius of rotation. This may be achieved without truncation if the gamma camera is large. We describe a commercially available clinical scanner mated with pinhole collimation and an external linear stage. The pinhole collimation gives high magnification. The linear stage allows for helical pinhole SPECT. We have used the system to image radiolabeled molecules in phantoms and small animals.

  1. Technetium-99m HM-PAO-SPECT study of regional cerebral perfusion in early Alzheimer's disease

    SciTech Connect

    Perani, D.; Di Piero, V.; Vallar, G.; Cappa, S.; Messa, C.; Bottini, G.; Berti, A.; Passafiume, D.; Scarlato, G.; Gerundini, P.

    1988-09-01

    Regional cerebral perfusion was evaluated by single photon emission computed tomography (SPECT) using technetium-99m hexamethylpropyleneamine oxime ((/sup 99m/Tc)HM-PAO) in sixteen patients with Alzheimer's disease (AD) in early clinical phase and in 16 healthy elderly controls. In all patients transmission computed tomography (TCT) and/or magnetic resonance imaging (MRI) did not show focal brain abnormalities. Relative to normal subjects, AD patients showed significant reductions in cortical/cerebellar activity ratio: cortical perfusion was globally depressed with the largest reductions in frontal and posterior temporo-parietal cortices. Asymmetries of relative perfusion between cerebral hemispheres were also demonstrated when language was affected or visuospatial functions were unevenly impaired. In patients with early AD, SPECT provides functional information to be compared with clinical and psychometric data.

  2. Characterization of a high-purity germanium detector for small-animal SPECT

    PubMed Central

    Johnson, Lindsay C; Campbell, Desmond L; Hull, Ethan L; Peterson, Todd E

    2011-01-01

    We present an initial evaluation of a mechanically-cooled, high-purity germanium double-sided strip detector as a potential gamma camera for small-animal SPECT. It is 90 mm in diameter and 10 mm thick with two sets of 16 orthogonal strips that have a 4.5 mm width with a 5 mm pitch. We found an energy resolution of 0.96% at 140 keV, an intrinsic efficiency of 43.3% at 122 keV and a FWHM spatial resolution of approximately 1.5 mm. We demonstrated depth-of-interaction estimation capability through comparison of pinhole acquisitions with a point source on and off axis. Finally, a flood-corrected-flood image exhibited a strip-level uniformity of less than 1%. This high-purity germanium offers many desirable properties for small-animal SPECT. PMID:21852723

  3. Thick Silicon Double-Sided Strip Detectors for Low-Energy Small-Animal SPECT

    PubMed Central

    Shokouhi, Sepideh; McDonald, Benjamin S.; Durko, Heather L.; Fritz, Mark A.; Furenlid, Lars R.; Peterson, Todd E.

    2010-01-01

    This work presents characterization studies of thick silicon double-sided strip detectors for a high-resolution small-animal SPECT. The dimension of these detectors is 60.4 mm × 60.4 mm × 1 mm. There are 1024 strips on each side that give the coordinates of the photon interaction, with each strip processed by a separate ASIC channel. Our measurement shows that intrinsic spatial resolution equivalent to the 59 μm strip pitch is attainable. Good trigger uniformity can be achieved by proper setting of a 4-bit DAC in each ASIC channel to remove trigger threshold variations. This is particularly important for triggering at low energies. The thick silicon DSSD (Double-sided strip detector) shows high potential for small-animal SPECT. PMID:20686626

  4. Aortic root infection in a prosthetic valve demonstrated by gallium-67 citrate SPECT.

    PubMed

    Thomson, L E J; Goodman, M P; Naqvi, T Z; Feldman, R; Buchbinder, N A; Waxman, A; D'Agnolo, A

    2005-04-01

    A 70-year-old man presented with 6 weeks of worsening low back pain, fever, sweating, and weight loss with known severe lumbosacral osteoarthritis. His history included CABG in 1992, porcine aortic valve replacement, and permanent pacemaker implantation in 2002. CT of the chest, abdomen, and pelvis did not demonstrate a cause for the symptoms. Blood cultures grew penicillin-sensitive enterococcus and he was referred for evaluation of possible osteodiskitis or epidural abscess. Gallium planar imaging demonstrated increased activity in the lumbar spine, suspicious for the presence of infection, and activity was noted in the mid mediastinum as well. SPECT clearly showed increased Ga-67 activity in the region of the aortic root, suspicious for infection. A perivalvular aortic root abscess was subsequently demonstrated by transesophageal echo. This case illustrates the value of Ga-67 chest SPECT in patients with prosthetic valves for detection of endocarditis. PMID:15764887

  5. Differential diagnosis of bilateral parietal abnormalities in I-123 IMP SPECT imaging

    SciTech Connect

    Kuwabara, Y.; Ichiya, Y.; Otsuka, M.; Tahara, T.; Fukumura, T.; Gunasekera, R.; Masuda, K. )

    1990-12-01

    This report discusses the clinical significance of bilateral parietal abnormalities on I-123 IMP SPECT imaging in 158 patients with cerebral disorders. This pattern was seen in 15 out of 21 patients with Alzheimer's disease; it was also seen in 4 out of 5 patients with Parkinson's disease with dementia, in 3 out of 17 patients with vascular dementia, in 1 out of 36 patients with cerebral infarction without dementia, in 1 out of 2 patients with hypoglycemia, and in 1 out of 2 patients with CO intoxication. Detection of bilateral parietal abnormalities is a useful finding in the diagnosis of Alzheimer's disease, but one should keep in mind that other cerebral disorders may also show a similar pattern with I-123 IMP SPECT imaging.

  6. PET and SPECT Imaging of Tumor Biology: New Approaches towards Oncology Drug Discovery and Development

    PubMed Central

    Van Dort, Marcian E.; Rehemtulla, Alnawaz; Ross, Brian D.

    2009-01-01

    Spiraling drug developmental costs and lengthy time-to-market introduction are two critical challenges facing the pharmaceutical industry. The clinical trials success rate for oncology drugs is reported to be 5% as compared to other therapeutic categories (11%) with most failures often encountered late in the clinical development process. PET and SPECT nuclear imaging technologies could play an important role in facilitating the drug development process improving the speed, efficiency and cost of drug development. This review will focus on recent studies of PET and SPECT radioligands in oncology and their application in the investigation of tumor biology. The use of clinically-validated radioligands as imaging-based biomarkers in oncology could significantly impact new cancer therapeutic development. PMID:19809593

  7. SPECT imaging with Tl-201 and Ga-67 in myocardial sarcoidosis

    SciTech Connect

    Kurata, C.; Sakata, K.; Taguchi, T.; Fukumoto, Y.; Miyata, H.; Aoshima, S.; Yamazaki, N. )

    1990-06-01

    Two patients with myocardial sarcoidosis are presented, both of whom underwent SPECT imaging with Tl-201 and Ga-67. The first had Ga-67 myocardial uptake with a Tl-201 defect, which disappeared with corticosteroid therapy. The second had multiple Tl-201 defects without Ga-67 uptake, which persisted despite corticosteroid therapy. Therefore, the combination of Tl-201 and Ga-67 imaging may be useful for recognizing myocardial sarcoidosis and for predicting the response to corticosteroid therapy.

  8. Identification of Angiogenesis Rich-Viable Myocardium using RGD Dimer based SPECT after Myocardial Infarction

    PubMed Central

    Lee, Min Su; Park, Hyun Soo; Lee, Byung Chul; Jung, Jae Ho; Yoo, Jung Sun; Kim, Sang Eun

    2016-01-01

    Cardiac healing after myocardial ischemia is a complex biological process. Advances in understanding of wound healing response have paved the way for clinical testing of novel molecular imaging to improve clinical outcomes. A key factor for assessing myocardial viability after ischemic injury is the evaluation of angiogenesis accompanying increased expression of integrin αvβ3. Here, we describe the capability of an αvβ3 integrin-targeting SPECT agent, 99mTc-IDA-D-[c(RGDfK)]2, for identification of ischemic but viable myocardium, i.e., hibernating myocardium which is crucial to predict functional recovery after revascularization, the standard care of cardiovascular medicine. In vivo SPECT imaging of rat models with transient coronary occlusion showed significantly high uptake of 99mTc-IDA-D-[c(RGDfK)]2 in the ischemic region. Comparative measurements with 201Tl SPECT and 18F-FDG PET, then, proved that such prominent uptake of 99mTc-IDA-D-[c(RGDfK)]2 exactly matched the hallmark of hibernation, i.e., the perfusion-metabolism mismatch pattern. The uptake of 99mTc-IDA-D-[c(RGDfK)]2 was non-inferior to that of 18F-FDG, confirmed by time-course variation analysis. Immunohistochemical characterization revealed that an intense signal of 99mTc-IDA-D-[c(RGDfK)]2 corresponded to the vibrant angiogenic events with elevated expression of αvβ3 integrin. Together, these results establish that 99mTc-IDA-D-[c(RGDfK)]2 SPECT can serve as a sensitive clinical measure for myocardial salvage to identify the patients who might benefit most from revascularization. PMID:27283041

  9. Results of the first beam time with the neutron decay spectrometer aSPECT

    NASA Astrophysics Data System (ADS)

    Baeßler, Stefan; Ayala Guardia, Fidel; Borg, Michael; Eberhardt, Klaus; Heil, Werner; Konrad, Gertrud; Muñoz Horta, Raquel; Sobolev, Yuri; Konorov, Igor; Petzoldt, Gerd; Simson, Martin; Zimmer, Oliver; Glück, Ferenc; Rich, Dennis

    2007-10-01

    With the neutron decay spectrometer aSPECT we aim to measure the proton spectrum in free neutron beta decay precisely. This allows us to determine the neutrino electron correlation coefficient a. We had our first test beam time in 2005/06 at the new neutron source FRM-II in Garching. In my talk I want to talk about the results, the systematic effects we found and the ways how to deal with them in later beam times.

  10. Nanosized multifunctional liposomes for tumor diagnosis and molecular imaging by SPECT/CT.

    PubMed

    Silindir, Mine; Erdoğan, Suna; Özer, A Yekta; Doğan, A Lale; Tuncel, Murat; Uğur, Ömer; Torchilin, Vladimir P

    2013-03-01

    Among currently used cancer imaging methods, nuclear medicine modalities provide metabolic information, whereas modalities in radiology provide anatomical information. However, different modalities, having different acquisition times in separate machines, decrease the specificity and accuracy of images. To solve this problem, hybrid imaging modalities were developed as a new era, especially in the cancer imaging field. With widespread usage of hybrid imaging modalities, specific contrast agents are essentially needed to use in both modalities, such as single-photon emission computed tomography/computed tomography (SPECT/CT). Liposomes are one of the most desirable drug delivery systems, depending on their suitable properties. The aim of this study was to develop a liposomal contrast agent for the diagnosis and molecular imaging of tumor by SPECT/CT. Liposomes were prepared nanosized, coated with polyethylene glycol to obtain long blood circulation, and modified with monoclonal antibody 2C5 for specific tumor targeting. Although DTPA-PE and DTPA-PLL-NGPE (polychelating amphilic polymers; PAPs) were loaded onto liposomes for stable radiolabeling for SPECT imaging, iopromide was encapsulated into liposomes for CT imaging. Liposomes [(DPPC:PEG(2000)-PE:Chol:DTPA-PE), (PL 90G:PEG(2000)-PE:Chol:DTPA-PE), (DPPC:PEG(2000)-PE:Chol:PAPs), (PL 90G:PEG(2000)-PE:Chol:PAPs), (60:0.9:39:0.1% mol ratio)] were characterized in terms of entrapment efficiency, particle size, physical stability, and release kinetics. Additionally, in vitro cell-binding studies were carried out on two tumor cell lines (MCF-7 and EL 4) by counting radioactivity. Tumor-specific antibody-modified liposomes were found to be effective multimodal contrast agents by designating almost 3-8 fold more uptake than nonmodified ones in different tumor cell lines. These results could be considered as an important step in the development of tumor-targeted SPECT/CT contrast agents for cancer imaging. PMID:23078019

  11. Reduced hypothalamic blood flow after radiation treatment of nasopharyngeal cancer: SPECT studies in 34 patients

    SciTech Connect

    Chieng, P.U.; Huang, T.S.; Chang, C.C.; Chong, P.N.; Tien, R.D.; Su, C.T. )

    1991-07-01

    To determine the effect of cranial irradiation on hypothalamic blood flow, the authors performed 44 regional cerebral blood flow studies with 99mTc hexamethyl propyleneamine oxime (HMPAO) single-photon emission CT (SPECT) on four normal volunteers and 34 patients with pathologically proved nasopharyngeal cancer. Twenty-three men and 15 women, 30-65 years old, were divided into four study groups: group 1 served as a control and consisted of four normal volunteers and six patients studied prior to cranial irradiation; group 2 patients had cranial irradiation half a year before the SPECT study (n = 12, one from group 1); group 3 patients were irradiated 1 year before the study (n = 13, three from group 1 and two from group 2); and group 4 patients were irradiated at least 5 years before SPECT imaging (n = 9). Six patients were studied twice. Quantification of the 99mTc-HMPAO brain SPECT studies was done separately by three radiologists to obtain the hypothalamus/occipital (H/O) and hypothalamus/parasagittal (H/P) ratios. Endocrinologic studies were performed in all cases and the hypothalamus-thyrotroph-thyroid, hypothalamus-gonadotroph-testis (ovary), hypothalamus-lactotroph, hypothalamus-somatotroph, and hypothalamus-corticotroph-adrenal axes were evaluated separately. They determined that regional hypothalamic blood flow was reduced after cranial irradiation in patients with nasopharyngeal cancer. The H/O ratio of groups 3 and 4 did not differ from that of group 2 (one-half year after cranial irradiation). The H/O ratio was significantly reduced 6 months and 1 year after cranial irradiation; mean {plus minus} SD = 0.5801 {plus minus} 0.0829 (p less than .025), 0.5725 {plus minus} 0.0791 (p less than .01) versus 0.6477 {plus minus} 0.0458 before cranial irradiation, respectively.

  12. Identification of Angiogenesis Rich-Viable Myocardium using RGD Dimer based SPECT after Myocardial Infarction.

    PubMed

    Lee, Min Su; Park, Hyun Soo; Lee, Byung Chul; Jung, Jae Ho; Yoo, Jung Sun; Kim, Sang Eun

    2016-06-10

    Cardiac healing after myocardial ischemia is a complex biological process. Advances in understanding of wound healing response have paved the way for clinical testing of novel molecular imaging to improve clinical outcomes. A key factor for assessing myocardial viability after ischemic injury is the evaluation of angiogenesis accompanying increased expression of integrin αvβ3. Here, we describe the capability of an αvβ3 integrin-targeting SPECT agent, (99m)Tc-IDA-D-[c(RGDfK)]2, for identification of ischemic but viable myocardium, i.e., hibernating myocardium which is crucial to predict functional recovery after revascularization, the standard care of cardiovascular medicine. In vivo SPECT imaging of rat models with transient coronary occlusion showed significantly high uptake of (99m)Tc-IDA-D-[c(RGDfK)]2 in the ischemic region. Comparative measurements with (201)Tl SPECT and (18)F-FDG PET, then, proved that such prominent uptake of (99m)Tc-IDA-D-[c(RGDfK)]2 exactly matched the hallmark of hibernation, i.e., the perfusion-metabolism mismatch pattern. The uptake of (99m)Tc-IDA-D-[c(RGDfK)]2 was non-inferior to that of (18)F-FDG, confirmed by time-course variation analysis. Immunohistochemical characterization revealed that an intense signal of (99m)Tc-IDA-D-[c(RGDfK)]2 corresponded to the vibrant angiogenic events with elevated expression of αvβ3 integrin. Together, these results establish that (99m)Tc-IDA-D-[c(RGDfK)]2 SPECT can serve as a sensitive clinical measure for myocardial salvage to identify the patients who might benefit most from revascularization.

  13. N-allyl epiderpride: An extremely potent SPECT radioligand for the dopamine D2 receptor

    SciTech Connect

    Kessler, R.M.; Mason, N.S.; Ansari, M.S.

    1994-05-01

    We have previously reported that epidepride is a potent (K{sub D} 24pM) and specific SPECT radioligand for the dopamine D2 receptor which can be used to study striatal and extrastriatal dopamine D2 receptors in man. We have synthesized and evaluated the N-allyl analogue of epiderpride (APID) as a potential SPECT radioligand for the dopamine D2 receptor. In comparison to epidepride it is even more potent at the dopamine D2 receptor, the K{sub D} for APID being 11 frontal cortical homogenate. The lipophilicity, evaluated using the log kw pH 7.5, was 2.9 versus 2.05 for epidepride. Competitive binding studies using rat striatal, hippocampal and frontal cortical homogenates showed high affinity for only dopamine D2 like cerebellar ratio of 275:1 at 320 minutes post injection-similar to that seen with epidepride, but with nearly four times higher brain uptake. Of interest was the off-rate from the dopamine D2 receptor; it was 0.0046 min{sup -1} in vitro at 25{degrees}C-corresponding to an t 1/2 of 150 minutes. Studies in rhesus monkeys show an in vivo off rate (following 2.5 mg/kg raclopride IV) of about 0.0082 min{sup -1} seen that with epidepride. SPECT studies in rhesus monkeys reveal APID is a promising SPECT radioligand that appears to be similar to epidepride, but with higher brain uptake due to its more optimal lipophilicity for entry into brain.

  14. Tc SPECT scan in a patient with occipital lobe infarction and complex visual hallucinations.

    PubMed

    Assadi, Mitra; Baseman, Susan; Hyman, Daniel

    2003-06-01

    We have described a patient with occipital lobe infarction and CVH in the hemianopic field. Increased uptake in the right temporal lobe was documented on the brain Tc SPECT scan. We propose that activation of this area might be the underlying mechanism for visual hallucinations. This case report is a clear example of the wide spectrum of the clinical manifestations in stroke victims. We also emphasize the importance of educating the medical staff about the organic basis for human behavior.

  15. Quantitative evaluation study of four-dimensional gated cardiac SPECT reconstruction †

    PubMed Central

    Jin, Mingwu; Yang, Yongyi; Niu, Xiaofeng; Marin, Thibault; Brankov, Jovan G.; Feng, Bing; Pretorius, P. Hendrik; King, Michael A.; Wernick, Miles N.

    2013-01-01

    In practice gated cardiac SPECT images suffer from a number of degrading factors, including distance-dependent blur, attenuation, scatter, and increased noise due to gating. Recently we proposed a motion-compensated approach for four-dimensional (4D) reconstruction for gated cardiac SPECT, and demonstrated that use of motion-compensated temporal smoothing could be effective for suppressing the increased noise due to lowered counts in individual gates. In this work we further develop this motion-compensated 4D approach by also taking into account attenuation and scatter in the reconstruction process, which are two major degrading factors in SPECT data. In our experiments we conducted a thorough quantitative evaluation of the proposed 4D method using Monte Carlo simulated SPECT imaging based on the 4D NURBS-based cardiac-torso (NCAT) phantom. In particular we evaluated the accuracy of the reconstructed left ventricular myocardium using a number of quantitative measures including regional bias-variance analyses and wall intensity uniformity. The quantitative results demonstrate that use of motion-compensated 4D reconstruction can improve the accuracy of the reconstructed myocardium, which in turn can improve the detectability of perfusion defects. Moreover, our results reveal that while traditional spatial smoothing could be beneficial, its merit would become diminished with the use of motion-compensated temporal regularization. As a preliminary demonstration, we also tested our 4D approach on patient data. The reconstructed images from both simulated and patient data demonstrated that our 4D method can improve the definition of the LV wall. PMID:19724094

  16. Identification of Angiogenesis Rich-Viable Myocardium using RGD Dimer based SPECT after Myocardial Infarction.

    PubMed

    Lee, Min Su; Park, Hyun Soo; Lee, Byung Chul; Jung, Jae Ho; Yoo, Jung Sun; Kim, Sang Eun

    2016-01-01

    Cardiac healing after myocardial ischemia is a complex biological process. Advances in understanding of wound healing response have paved the way for clinical testing of novel molecular imaging to improve clinical outcomes. A key factor for assessing myocardial viability after ischemic injury is the evaluation of angiogenesis accompanying increased expression of integrin αvβ3. Here, we describe the capability of an αvβ3 integrin-targeting SPECT agent, (99m)Tc-IDA-D-[c(RGDfK)]2, for identification of ischemic but viable myocardium, i.e., hibernating myocardium which is crucial to predict functional recovery after revascularization, the standard care of cardiovascular medicine. In vivo SPECT imaging of rat models with transient coronary occlusion showed significantly high uptake of (99m)Tc-IDA-D-[c(RGDfK)]2 in the ischemic region. Comparative measurements with (201)Tl SPECT and (18)F-FDG PET, then, proved that such prominent uptake of (99m)Tc-IDA-D-[c(RGDfK)]2 exactly matched the hallmark of hibernation, i.e., the perfusion-metabolism mismatch pattern. The uptake of (99m)Tc-IDA-D-[c(RGDfK)]2 was non-inferior to that of (18)F-FDG, confirmed by time-course variation analysis. Immunohistochemical characterization revealed that an intense signal of (99m)Tc-IDA-D-[c(RGDfK)]2 corresponded to the vibrant angiogenic events with elevated expression of αvβ3 integrin. Together, these results establish that (99m)Tc-IDA-D-[c(RGDfK)]2 SPECT can serve as a sensitive clinical measure for myocardial salvage to identify the patients who might benefit most from revascularization. PMID:27283041

  17. Machine-learning model observer for detection and localization tasks in clinical SPECT-MPI

    NASA Astrophysics Data System (ADS)

    Parages, Felipe M.; O'Connor, J. Michael; Pretorius, P. Hendrik; Brankov, Jovan G.

    2016-03-01

    In this work we propose a machine-learning MO based on Naive-Bayes classification (NB-MO) for the diagnostic tasks of detection, localization and assessment of perfusion defects in clinical SPECT Myocardial Perfusion Imaging (MPI), with the goal of evaluating several image reconstruction methods used in clinical practice. NB-MO uses image features extracted from polar-maps in order to predict lesion detection, localization and severity scores given by human readers in a series of 3D SPECT-MPI. The population used to tune (i.e. train) the NB-MO consisted of simulated SPECT-MPI cases - divided into normals or with lesions in variable sizes and locations - reconstructed using filtered backprojection (FBP) method. An ensemble of five human specialists (physicians) read a subset of simulated reconstructed images, and assigned a perfusion score for each region of the left-ventricle (LV). Polar-maps generated from the simulated volumes along with their corresponding human scores were used to train five NB-MOs (one per human reader), which are subsequently applied (i.e. tested) on three sets of clinical SPECT-MPI polar maps, in order to predict human detection and localization scores. The clinical "testing" population comprises healthy individuals and patients suffering from coronary artery disease (CAD) in three possible regions, namely: LAD, LcX and RCA. Each clinical case was reconstructed using three reconstruction strategies, namely: FBP with no SC (i.e. scatter compensation), OSEM with Triple Energy Window (TEW) SC method, and OSEM with Effective Source Scatter Estimation (ESSE) SC. Alternative Free-Response (AFROC) analysis of perfusion scores shows that NB-MO predicts a higher human performance for scatter-compensated reconstructions, in agreement with what has been reported in published literature. These results suggest that NB-MO has good potential to generalize well to reconstruction methods not used during training, even for reasonably dissimilar datasets (i

  18. First true initial ictal SPECT in partial epilepsy verified by electroencephalography

    PubMed Central

    Pastor, Jesús; Domínguez-Gadea, Luis; Sola, Rafael G; Hernando, Virgilio; Meilán, María Luisa; Dios, Eva De; Martínez-Chacón, José Luis; Martínez, Marcos

    2008-01-01

    Drug-resistant epilepsy can sometimes be treated by surgery. In these cases, an accurate identification of the epileptogenic area must be addressed before resection. Ictal SPECT is one of the presurgical evaluations that can be performed, but usually, the increase in the regional cerebral perfusion observed is produced by diffusion of ictal activity. Here we describe a patient studied with v-EEG and foramen ovale electrodes that suffered a seizure after intravenous infusion of etomidate. The sequence of etomidate administration, followed by radiotracer and seizure was good enough for us to suspect that a true initial ictal SPECT was observed. We have implemented a kinetic model with four compartments, previously described (Andersen 1989), in order to estimate the fraction of hydrophilic radiotracer in the brain during the pre-ictal and ictal periods. This model has shown that the fraction of hydrophilic radiotracer during the seizure into the brain would be between 18.9% and 42.3% of total infused. We show the first true initial ictal SPECT demonstrated by bioelectrical recordings of the brain activity, obtained by a correct succession of events and compatible with theoretical data obtained from the kinetic model. PMID:18728803

  19. Radionuclide (131)I-labeled multifunctional dendrimers for targeted SPECT imaging and radiotherapy of tumors.

    PubMed

    Zhu, Jingyi; Zhao, Lingzhou; Cheng, Yongjun; Xiong, Zhijuan; Tang, Yueqin; Shen, Mingwu; Zhao, Jinhua; Shi, Xiangyang

    2015-11-21

    We report the synthesis, characterization, and utilization of radioactive (131)I-labeled multifunctional dendrimers for targeted single-photon emission computed tomography (SPECT) imaging and radiotherapy of tumors. In this study, amine-terminated poly(amidoamine) dendrimers of generation 5 (G5·NH2) were sequentially modified with 3-(4'-hydroxyphenyl)propionic acid-OSu (HPAO) and folic acid (FA) linked with polyethylene glycol (PEG), followed by acetylation modification of the dendrimer remaining surface amines and labeling of radioactive iodine-131 ((131)I). The generated multifunctional (131)I-G5·NHAc-HPAO-PEG-FA dendrimers were characterized via different methods. We show that prior to (131)I labeling, the G5·NHAc-HPAO-PEG-FA dendrimers conjugated with approximately 9.4 HPAO moieties per dendrimer are noncytotoxic at a concentration up to 20 μM and are able to target cancer cells overexpressing FA receptors (FAR), thanks to the modified FA ligands. In the presence of a phenol group, radioactive (131)I is able to be efficiently labeled onto the dendrimer platform with good stability and high radiochemical purity, and render the platform with an ability for targeted SPECT imaging and radiotherapy of an FAR-overexpressing xenografted tumor model in vivo. The designed strategy to use the facile dendrimer nanotechnology may be extended to develop various radioactive theranostic nanoplatforms for targeted SPECT imaging and radiotherapy of different types of cancer.

  20. Differential diagnosis of regional cerebral hyperfixation of TC-99m HMPAO on SPECT imaging

    SciTech Connect

    Shirazi, P.; Konopka, L.; Crayton, J.W.

    1994-05-01

    Accurate diagnostic evaluation of patients with neurologic and neuropsychiatric disease is important because early treatment may halt disease progression and prevent impairment or disability. Cerebral hyperfixation of HMPAO has been ascribed to luxury perfusion following ischemic infarction. The present study sought to identify other conditions that also display radiotracer hyperfixation in order to develop a differential diagnosis of this finding on SPECT imaging. Two hundred fifty (n=250) successive cerebral SPECT images were reviewed for evidence of HMPAO hyperfixation. Hyperfixation was defined as enhanced focal perfusion surrounded by a zone of diminished or normal cerebral perfusion. All patients were scanned after intravenous injection of 25 mCi Tc-99m HMPAO. Volume-rendered and oblique images were obtained with a Trionix triple-head SPECT system using ultra high resolution fan beam collimators. Thirteen (13/250; 5%) of the patients exhibited regions of HMPAO hyperfixation. CT or MRI abnormalities were detected in 6/13 cases. Clinical diagnoses in these patients included intractable psychosis, post-traumatic stress disorder, alcohol and narcotic dependence, major depression, acute closed-head trauma, hypothyroidism, as well as subacute ischemic infarction. A wide variety of conditions may be associated with cerebral hyperfixation of HMPAO. These conditions include neurologic and psychiatric diagnoses, and extend the consideration of hyperfixation beyond ischemic infarction. Consequently, a differential diagnosis of HMPAO hyperfixation may be broader than originally considered, and this may suggest a fundamental role for local cerebral hyperperfusion. Elucidation of the fundamental mechanism(s) for cerebral hyperperfusion requires further investigation.

  1. Measurement of myocardial wall thickening from PET/SPECT images: Comparison of two methods

    SciTech Connect

    Bartlett, M.L.; Mok, D.; Dilsizian, V.

    1996-05-01

    We compared two methods for measuring myocardial wall thickening from nuclear medicine perfusion scans. The first method uses the percent change in peak activity, and the second method models a profile measured across the myocardium. Mathematical simulations of the myocardium were used. In addition, images with PET or SPECT resolution were created from real MR images. Known amounts of noise were then added. The percent peak thickening (%PT) is nonlinear with true percent thickening, especially for PET resolutions [7 mm full width at half-maximum (FWHM)]. For the peak method, low levels of noise (10%) introduced an error of 8%PT for PET and of 16%PT for SPECT. Additional smoothing reduced these errors. For the fitted model, at 10% noise, the error in thickening was large: 2.3 mm for PET and 7.8 mm for SPECT. The fitted model works well only with good resolution and low noise (e.g., 7 mm FWHM and 10%). The peak method is also sensitive to noise, especially for poorer resolutions. Additional smoothing gives more reliable results for the peak method but not the fitted method. The peak method is therefore the more generally reliable, but even this method may only allow classification of myocardial thickening into broad categories. 13 refs., 4 figs., 2 tabs.

  2. SPECT study of low intensity He-Ne laser intravascular irradiation therapy for brain infarction

    NASA Astrophysics Data System (ADS)

    Xiao, Xue-Chang; Dong, Jia-Zheng; Chu, Xiao-Fan; Jia, Shao-Wei; Liu, Timon C.; Jiao, Jian-Ling; Zheng, Xi-Yuan; Zhou, Ci-Xiong

    2003-12-01

    We used single photon emission computed tomography (SPECT) in brain perfusion imaging to study the changes of regional cerebral blood flow (rCBF) and cerebral function in brain infarction patients treated with intravascular laser irradiation of blood (ILIB). 17 of 35 patients with brain infarction were admitted to be treated by ILIB on the base of standard drug therapy, and SPECT brain perfusion imaging was performed before and after ILIB therapy with self-comparison. The results were analyzed in quantity with brain blood flow function change rate (BFCR%) model. Effect of ILIB during the therapy process in the other 18 patients were also observed. In the 18 patients, SPECT indicated an improvement of rCBF (both in focus and in total brain) and cerebral function after a 30 min-ILIB therapy. And the 17 patients showed an enhancement of total brain rCBF and cerebral function after ILIB therapy in comparison with that before, especially for the focus side of the brain. The enhancement for focus itself was extremely obvious with a higher significant difference (P<0.0001). The mirror regions had no significant change (P>0.05). BFCR% of foci was prominently higher than that of mirror regions (P<0.0001). In conclusion, the ILIB therapy can improve rCBF and cerebral function and activate brain cells of patients with brain infarction. The results denote new evidence of ILIB therapy for those patients with cerebral ischemia.

  3. Functional imaging of brain maturation in humans using iodine-123 iodoamphetamine and SPECT

    SciTech Connect

    Rubinstein, M.; Denays, R.; Ham, H.R.; Piepsz, A.; VanPachterbeke, T.; Haumont, D.; Nol, P. )

    1989-12-01

    The application of regional cerebral blood flow (rCBF) study by means of lipophilic radiotracers and single photon emission computed (SPECT) devices in very young infants is hampered by the considerable changes of rCBF pattern as a result of the cerebral maturation process. In an attempt to determine the normal evolution of ({sup 123}I)IMP SPECT pattern as a function of age, we retrospectively selected the studies of 30 babies with normal clinical examination, EEG and CT or ultrasound scans at time of SPECT. There was a marked predominance of the thalamic perfusion over cortical areas until the end of the second month. The distribution of regional cortical activity followed a strict sequence. The perfusion of both parietal and occipital areas was well-visualized around the 40th week of gestational age and thereafter rapidly rose, always, however, with a slight predominance of the parietal activity. At the opposite, frontal activity which remained scarcely recognizable up to the second month tremendously rose to present the adult-like pattern at the beginning of the second year. The rCBF changes described above are well in agreement with the behavioral evolution occurring during prime infancy.

  4. Pattern of brain blood perfusion in tinnitus patients using technetium-99m SPECT imaging

    PubMed Central

    Mahmoudian, Saeid; Farhadi, Mohammad; Gholami, Saeid; Saddadi, Fariba; Karimian, Ali Reza; Mirzaei, Mohammad; Ghoreyshi, Esmaeel; Ahmadizadeh, Majid; Lenarz, Thomas

    2012-01-01

    Background and Purpose: Tinnitus is associated with an increased activity in central auditory system as demonstrated by neuroimaging studies. Brain perfusion scanning using single photon emission computed tomography (SPECT) was done to understand the pattern of brain blood perfusion of tinnitus subjects and find the areas which are mostly abnormal in these patients. Materials and Methods: A number of 122 patients with tinnitus were enrolled to this cross-sectional study. They underwent SPECT and magnetic resonance imaging (MRI) of brain, and the images were fused to find the regions with abnormal perfusion. Results: SPECT scan results were abnormal in 101 patients (83%). Most patients had bilateral abnormal perfusion (N = 65, 53.3%), and most subjects had abnormality in middle-temporal gyrus (N = 83, 68%) and temporoparietal cortex (N = 46, 37.7%). Patients with multifocal involvement had the least mean age than other 2 groups (patients with no abnormality and unifocal abnormality) (P value = 0.045). Conclusions: Brain blood perfusion pattern differs in patient with tinnitus than others. These patients have brain perfusion abnormality, mostly in auditory gyrus (middle temporal) and associative cortex (temporoparietal cortex). Multifocal abnormalities might be due to more cognitive and emotional brain centers involvement due to tinnitus or more stress and anxiety of tinnitus in the young patients. PMID:23267375

  5. The use of SPECT to evaluate growth cessation of the mandible in unilateral condylar hyperplasia.

    PubMed

    Pripatnanont, P; Vittayakittipong, P; Markmanee, U; Thongmak, S; Yipintsoi, T

    2005-06-01

    In unilateral condylar hyperplasia, for surgical intervention to be effective, the status of condylar bone growth has to be assessed correctly. Previously this assessment relied on serial clinical observations. This study aimed to evaluate the MDP-SPECT method of assessing condylar growth in unilateral condylar hyperplasia. Twenty-six MDP-SPECT of the mandible had been performed; 21 were diagnosed as condylar hyperplasia and five as non-mandibular disease. Three isotope parameters: isotope counts, pixel counts and counts per pixel were summed for each condyle per subject. The percentage difference in isotope uptake of the three parameters between the two condyles was calculated as the ratio of the combined counts of the two sides. These differences significantly correlated with each other (Pearson r=0.78-0.98) and with the clinical status of bone growth (Spearman rho=0.72-0.86). There was a significant difference for the count per pixel between the 'growing' condyle (transaxial, T: 15.05+/-7.14, coronal, C: 12.29+/-7.88), the 'no further growth' condyle (T: 5.22+/-4.08, C: 5.67+/-3.88) and the 'normal' condyle (T: 0.82+/-0.76, C: 1.34+/-0.66). This method was able to separate 'active growth' from 'growth cessation' of the condyle by a single MDP-SPECT of the mandible. However, further studies are needed to confirm this finding. PMID:16053843

  6. Effect of geometric and motion tracking errors on awake small animal SPECT

    SciTech Connect

    Lee, Seung Joon; Baba, Justin S; Goddard Jr, James Samuel; Weisenberger, A G; Stolin, A; McKisson, J; Smith, M F

    2009-01-01

    A series of simulation studies were performed to evaluate the effects of geometric and motion tracking errors on reconstruction image quality for a single pinhole collimator awake animal imaging SPECT system. List-mode SPECT data generated using a custom Monte Carlo program that incorporated experimental mouse motion data were reconstructed by MLEM with Siddon's ray tracing. To better understand the impact of motion tracking and system geometric parameter errors on reconstructed system data, an offset of up to 1 mm or degree was separately applied to each for evaluation. In the absence of motion tracking or system geometric error, the applied motion compensation algorithm successfully reconstructed volumes without any degradation or distortion. Presented results reveal that motion tracking errors propagate through the SPECT reconstruction process. However, it is confirmed that the impact of tracking errors in the currently employed motion tracking system, is minimal because of their accuracy. The results also reveal the direct and indirect impact of geometric errors to motion compensated reconstruction quality and that a wrong assumption of pinhole transaxial position produces the most amount of distortion of all the investigated errors. Finally, system geometric errors are shown to have a greater impact on reconstruction quality than equivalent tracking errors.

  7. Towards Quantification of Functional Breast Images Using Dedicated SPECT With Non-Traditional Acquisition Trajectories

    PubMed Central

    Perez, Kristy L.; Cutler, Spencer J.; Madhav, Priti; Tornai, Martin P.

    2012-01-01

    Quantification of radiotracer uptake in breast lesions can provide valuable information to physicians in deciding patient care or determining treatment efficacy. Physical processes (e.g., scatter, attenuation), detector/collimator characteristics, sampling and acquisition trajectories, and reconstruction artifacts contribute to an incorrect measurement of absolute tracer activity and distribution. For these experiments, a cylinder with three syringes of varying radioactivity concentration, and a fillable 800 mL breast with two lesion phantoms containing aqueous 99mTc pertechnetate were imaged using the SPECT sub-system of the dual-modality SPECT-CT dedicated breast scanner. SPECT images were collected using a compact CZT camera with various 3D acquisitions including vertical axis of rotation, 30° tilted, and complex sinusoidal trajectories. Different energy windows around the photopeak were quantitatively compared, along with appropriate scatter energy windows, to determine the best quantification accuracy after attenuation and dual-window scatter correction. Measured activity concentrations in the reconstructed images for syringes with greater than 10 µCi /mL corresponded to within 10% of the actual dose calibrator measured activity concentration for ±4% and ±8% photopeak energy windows. The same energy windows yielded lesion quantification results within 10% in the breast phantom as well. Results for the more complete complex sinsusoidal trajectory are similar to the simple vertical axis acquisition, and additionally allows both anterior chest wall sampling, no image distortion, and reasonably accurate quantification. PMID:22262925

  8. Cardiac SPECT/CCTA hybrid imaging : One answer to two questions?

    PubMed

    Kaufmann, P A; Buechel, R R

    2016-08-01

    Noninvasive cardiac imaging has witnessed tremendous advances in the recent past, particularly with regard to coronary computed tomography angiography (CCTA) where substantial improvements in image quality have been achieved while at the same time patients' radiation dose exposure has been reduced to the sub-millisievert range. Similarly, for single-photon emission computed tomography (SPECT) the introduction of novel cadmium-zinc-telluride-based semiconductor detectors has significantly improved system sensitivity and image quality, enabling fast image acquisition within less than 2-3 min or reduction of radiation dose exposure to less than 5 mSv. However, neither imaging modality alone is able to fully cover the two aspects of coronary artery disease (CAD), that is, morphology and function. Both modalities have distinct advantages and shortcomings: While CCTA may prove a superb modality for excluding CAD through its excellent negative predictive value, it does not allow for assessment of hemodynamic relevance if obstructive coronary lesions are detected. Conversely, SPECT myocardial perfusion imaging cannot provide any information on the presence or absence of subclinical coronary atherosclerosis. This article aims to highlight the great potential of cardiac hybrid imaging that allows for a comprehensive evaluation of CAD through combination of both morphological and functional information by fusing SPECT with CCTA. PMID:27286848

  9. Towards Quantification of Functional Breast Images Using Dedicated SPECT With Non-Traditional Acquisition Trajectories.

    PubMed

    Perez, Kristy L; Cutler, Spencer J; Madhav, Priti; Tornai, Martin P

    2011-10-01

    Quantification of radiotracer uptake in breast lesions can provide valuable information to physicians in deciding patient care or determining treatment efficacy. Physical processes (e.g., scatter, attenuation), detector/collimator characteristics, sampling and acquisition trajectories, and reconstruction artifacts contribute to an incorrect measurement of absolute tracer activity and distribution. For these experiments, a cylinder with three syringes of varying radioactivity concentration, and a fillable 800 mL breast with two lesion phantoms containing aqueous (99m)Tc pertechnetate were imaged using the SPECT sub-system of the dual-modality SPECT-CT dedicated breast scanner. SPECT images were collected using a compact CZT camera with various 3D acquisitions including vertical axis of rotation, 30° tilted, and complex sinusoidal trajectories. Different energy windows around the photopeak were quantitatively compared, along with appropriate scatter energy windows, to determine the best quantification accuracy after attenuation and dual-window scatter correction. Measured activity concentrations in the reconstructed images for syringes with greater than 10 µCi /mL corresponded to within 10% of the actual dose calibrator measured activity concentration for ±4% and ±8% photopeak energy windows. The same energy windows yielded lesion quantification results within 10% in the breast phantom as well. Results for the more complete complex sinsusoidal trajectory are similar to the simple vertical axis acquisition, and additionally allows both anterior chest wall sampling, no image distortion, and reasonably accurate quantification.

  10. Quantitative I-123-IMP brain SPECT and neuropsychological testing in AIDS dementia

    SciTech Connect

    Kuni, C.C.; Rhame, F.S.; Meier, M.J.; Foehse, M.C.; Loewenson, R.B.; Lee, B.C.; Boudreau, R.J.; duCret, R.P. )

    1991-03-01

    We performed I-123-IMP SPECT brain imaging on seven mildly demented AIDS patients and seven normal subjects. In an attempt to detect and quantitate regions of decreased I-123-IMP uptake, pixel intensity histograms of normalized SPECT images at the basal ganglia level were analyzed for the fraction of pixels in the lowest quartile of the intensity range. This fraction (F) averaged 17.5% (S.D. = 4.6) in the AIDS group and 12.6% (S.D. = 5.1) in the normal group (p less than .05). Six of the AIDS patients underwent neuropsychological testing (NPT). NPT showed the patients to have a variety of mild abnormalities. Regression analysis of NPT scores versus F yielded a correlation coefficient of .80 (p less than .05). We conclude that analysis of I-123-IMP SPECT image pixel intensity distribution is potentially sensitive in detecting abnormalities associated with AIDS dementia and may correlate with the severity of dementia as measured by NPT.

  11. Dual head HIPDM SPECT imaging in the differential diagnosis of dementia with MR and CT correlation

    SciTech Connect

    Wellman, H.N.; Gilmor, R.; Hendrie, H.; Mock, B.; Kapuscinski, A.; Appledorn, C.R.; Krepshaw, J.

    1985-05-01

    Dual head SPECT brain imaging was performed in 25 patients with a clinical diagnosis of dementia approximately one-half hour after a 5mCi dose of high purity (p,5n) I-123 HIPDM (N,N,N'-Trimethyl-N'-(2-hydroxy-3-methyl-5-iodobenzyl)- 1,3-propane diamine). Tomographic reconstruction used a 30th order, moderate cutoff (0.2) Butterworth filter found previously to optimize low noise and conspicuity. Most patients had CT and MR imaging and some patients were studied more than once. In approximately one-half of patients referred with a diagnosis of dementia of the Alzheimer's type, SPECT results were consistent with multiple infarct dementia (MID). MR studies in most of these patients with MID demonstrated multiple white matter defects correlating with multiple gray matter defects seen with SPECT and consistent with angiogenic disease of the Binswanger's type. While CT demonstrated cortical abnormalities in some patients, the findings were often nonspecific with enlarged ventricles and widened sulci.

  12. Effect of geometric and motion tracking error for awake small animal SPECT

    SciTech Connect

    S.J. Lee, J.S. Baba, J. S. Goddard, A. Stolin, J. McKisson, A.G. Weisenberger, M.F. Smith

    2010-01-01

    A series of simulation studies were performed to evaluate the effects of geometric and motion tracking errors on reconstruction image quality for a single pinhole collimator awake animal imaging SPECT system. List-mode SPECT data generated using a custom Monte Carlo program that incorporated experimental mouse motion data were reconstructed by MLEM with Siddon's ray tracing. To better understand the impact of motion tracking and system geometric parameter errors on reconstructed system data, an offset of up to 1 mm or degree was separately applied to each for evaluation. In the absence of motion tracking or system geometric error, the applied motion compensation algorithm successfully reconstructed volumes without any degradation or distortion. Presented results reveal that motion tracking errors propagate through the SPECT reconstruction process. However, it is confirmed that the impact of tracking errors in the currently employed motion tracking system, is minimal because of their accuracy. The results also reveal the direct and indirect impact of geometric errors to motion compensated reconstruction quality and that a wrong assumption of pinhole transaxial position produces the most amount of distortion of all the investigated errors. Finally, system geometric errors are shown to have a greater impact on reconstruction quality than equivalent tracking errors.

  13. Exact Reconstruction From Uniformly Attenuated Helical Cone-Beam Projections in SPECT

    SciTech Connect

    Gullberg, Grant T; Huang, Qiu; You, Jiangsheng; Zeng, Gengsheng L.

    2008-12-18

    In recent years the development of cone-beam reconstruction algorithms has been an active research area in x-ray computed tomography (CT), and significant progress has been made in the advancement of algorithms. Theoretically exact and computationally efficient analytical algorithms can be found in the literature. However, in single photon emission computed tomography (SPECT), published cone-beam reconstruction algorithms are either approximate or involve iterative methods. The SPECT reconstruction problem is more complicated due to degradations in the imaging detection process, one of which is the effect of attenuation of gamma ray photons. Attenuation should be compensated for to obtain quantitative results. In this paper, an analytical reconstruction algorithm for uniformly attenuated cone-beam projection data is presented for SPECT imaging. The algorithm adopts the DBH method, a procedure consisting of differentiation and backprojection followed by a finite inverse cosh-weighted Hilbert transform. The significance of the proposed approach is that a selected region of interest can be reconstructed even with a detector with a reduced field of view. The algorithm is designed for a general trajectory. However, to validate the algorithm, a numerical study was performed using a helical trajectory. The implementation is efficient and the simulation result is promising.

  14. Comparison of rubidium-82 positron emission tomography and thallium-201 SPECT imaging for detection of coronary artery disease

    SciTech Connect

    Stewart, R.E.; Schwaiger, M.; Molina, E.; Popma, J.; Gacioch, G.M.; Kalus, M.; Squicciarini, S.; al-Aouar, Z.R.; Schork, A.; Kuhl, D.E. )

    1991-06-15

    The diagnostic performance of rubidium-82 (Rb-82) positron emission tomography (PET) and thallium-201 (Tl-201) single-photon emission-computed tomography (SPECT) for detecting coronary artery disease was investigated in 81 patients (52 men, 29 women). PET studies using 60 mCi of Rb-82 were performed at baseline and after intravenous infusion of 0.56 mg/kg dipyridamole in conjunction with handgrip stress. Tl-201 SPECT was performed after dipyridamole-handgrip stress and, in a subset of patients, after treadmill exercise. Sensitivity, specificity and overall diagnostic accuracy were assessed using both visually and quantitatively interpreted coronary angiograms. The overall sensitivity, specificity and accuracy of PET for detection of coronary artery disease (greater than 50% diameter stenosis) were 84, 88 and 85%, respectively. In comparison, the performance of SPECT revealed a sensitivity of 84%, specificity of 53% (p less than 0.05 vs PET) and accuracy of 79%. Similar results were obtained using either visual or quantitative angiographic criteria for severity of coronary artery disease. In 43 patients without prior myocardial infarction, the sensitivity for detection of disease was 71 and 73%, respectively, similar for both PET and SPECT. There was no significant difference in diagnostic performance between imaging modalities when 2 different modes of stress (exercise treadmill vs intravenous dipyridamole plus handgrip) were used with SPECT imaging. Thus, Rb-82 PET provides improved specificity compared with Tl-201 SPECT for identifying coronary artery disease, most likely due to the higher photon energy of Rb-82 and attenuation correction provided by PET. However, post-test referral cannot be entirely excluded as a potential explanation for the lower specificity of Tl-201 SPECT.

  15. Use of the FLUKA Monte Carlo code for 3D patient-specific dosimetry on PET-CT and SPECT-CT images.

    PubMed

    Botta, F; Mairani, A; Hobbs, R F; Vergara Gil, A; Pacilio, M; Parodi, K; Cremonesi, M; Coca Pérez, M A; Di Dia, A; Ferrari, M; Guerriero, F; Battistoni, G; Pedroli, G; Paganelli, G; Torres Aroche, L A; Sgouros, G

    2013-11-21

    Patient-specific absorbed dose calculation for nuclear medicine therapy is a topic of increasing interest. 3D dosimetry at the voxel level is one of the major improvements for the development of more accurate calculation techniques, as compared to the standard dosimetry at the organ level. This study aims to use the FLUKA Monte Carlo code to perform patient-specific 3D dosimetry through direct Monte Carlo simulation on PET-CT and SPECT-CT images. To this aim, dedicated routines were developed in the FLUKA environment. Two sets of simulations were performed on model and phantom images. Firstly, the correct handling of PET and SPECT images was tested under the assumption of homogeneous water medium by comparing FLUKA results with those obtained with the voxel kernel convolution method and with other Monte Carlo-based tools developed to the same purpose (the EGS-based 3D-RD software and the MCNP5-based MCID). Afterwards, the correct integration of the PET/SPECT and CT information was tested, performing direct simulations on PET/CT images for both homogeneous (water) and non-homogeneous (water with air, lung and bone inserts) phantoms. Comparison was performed with the other Monte Carlo tools performing direct simulation as well. The absorbed dose maps were compared at the voxel level. In the case of homogeneous water, by simulating 10(8) primary particles a 2% average difference with respect to the kernel convolution method was achieved; such difference was lower than the statistical uncertainty affecting the FLUKA results. The agreement with the other tools was within 3–4%, partially ascribable to the differences among the simulation algorithms. Including the CT-based density map, the average difference was always within 4% irrespective of the medium (water, air, bone), except for a maximum 6% value when comparing FLUKA and 3D-RD in air. The results confirmed that the routines were properly developed, opening the way for the use of FLUKA for patient-specific, image

  16. Use of the FLUKA Monte Carlo code for 3D patient-specific dosimetry on PET-CT and SPECT-CT images*

    PubMed Central

    Botta, F; Mairani, A; Hobbs, R F; Vergara Gil, A; Pacilio, M; Parodi, K; Cremonesi, M; Coca Pérez, M A; Di Dia, A; Ferrari, M; Guerriero, F; Battistoni, G; Pedroli, G; Paganelli, G; Torres Aroche, L A; Sgouros, G

    2014-01-01

    Patient-specific absorbed dose calculation for nuclear medicine therapy is a topic of increasing interest. 3D dosimetry at the voxel level is one of the major improvements for the development of more accurate calculation techniques, as compared to the standard dosimetry at the organ level. This study aims to use the FLUKA Monte Carlo code to perform patient-specific 3D dosimetry through direct Monte Carlo simulation on PET-CT and SPECT-CT images. To this aim, dedicated routines were developed in the FLUKA environment. Two sets of simulations were performed on model and phantom images. Firstly, the correct handling of PET and SPECT images was tested under the assumption of homogeneous water medium by comparing FLUKA results with those obtained with the voxel kernel convolution method and with other Monte Carlo-based tools developed to the same purpose (the EGS-based 3D-RD software and the MCNP5-based MCID). Afterwards, the correct integration of the PET/SPECT and CT information was tested, performing direct simulations on PET/CT images for both homogeneous (water) and non-homogeneous (water with air, lung and bone inserts) phantoms. Comparison was performed with the other Monte Carlo tools performing direct simulation as well. The absorbed dose maps were compared at the voxel level. In the case of homogeneous water, by simulating 108 primary particles a 2% average difference with respect to the kernel convolution method was achieved; such difference was lower than the statistical uncertainty affecting the FLUKA results. The agreement with the other tools was within 3–4%, partially ascribable to the differences among the simulation algorithms. Including the CT-based density map, the average difference was always within 4% irrespective of the medium (water, air, bone), except for a maximum 6% value when comparing FLUKA and 3D-RD in air. The results confirmed that the routines were properly developed, opening the way for the use of FLUKA for patient-specific, image

  17. Development of a Position Decoding ASIC for SPECT using Silicon Photomultiplier

    NASA Astrophysics Data System (ADS)

    Cho, M.; Kim, H.; Lim, K. T.; Cho, G.

    2016-01-01

    Single Photon Emission Computed Tomography(SPECT) is a widely used diagnosis modality for detecting metabolic diseases. In general, SPECT system is consisted of a sensor, a pre-amplifier, position decoding circuits(PDC) and a data acquisition(DAQ) system. Due to such complexity, it is quite costly to assemble SPECT system by putting discrete components together. Moreover, using discrete components would make the system rather bulky. In this work, we designed a channel module ASIC for SPECT system. This system was composed of a transimpedance amplifier(TIA), comparators and digital logics. In this particular module, a TIA was selected as a preamplifier because the decay time and the rise time are shorter than that of other preamplifier topologies. In the proposed module, the amplified pulse from the TIA was split into two separate signals and each signal was then fed into two comparators with different reference levels, e.g., a low and high level. Then an XOR gate combined the comparator outputs and the output of XOR gate was sent to the suceeding digital logic. Furthermore, the output of each component in the module is composed of a signal packet. The packet includes the information on the energy, the time and the position of the incident photon. The energy and position information of a detected radiation can be derived from the output of the D-flipflop(DFF) in the module via time-over-threshold(TOT). The timing information was measured using a delayed rising edge from the low-level referenced comparator. There are several advantages in developing the channel module ASIC. First of all, the ASIC has only digital outputs and thus a correction circuit for analog signal distortion can be neglected. In addition, it is possible to cut down the system production cost because the volume of the system can be reduced due to the compactness of ASIC. The benefits of channel module is not only limited to SPECT but also beneficial to many other radiation detecting systems.

  18. Development of a combined microSPECT/CT system for small animal imaging

    NASA Astrophysics Data System (ADS)

    Sun, Mingshan

    Modern advances in the biomedical sciences have placed increased attention on small animals such as mice and rats as models of human biology and disease in biological research and pharmaceutical development. Their small size and fast breeding rate, their physiologic similarity to human, and, more importantly, the availability of sophisticated genetic manipulations, all have made mice and rats the laboratory mammals of choice in these experimental studies. However, the increased use of small animals in biomedical research also calls for new instruments that can measure the anatomic and metabolic information noninvasively with adequate spatial resolution and measurement sensitivity to facilitate these studies. This dissertation describes the engineering development of a combined single photon emission computed tomography (SPECT) and X-ray computed tomography (CT) system dedicated for small animals imaging. The system aims to obtain both the anatomic and metabolic images with submillimeter spatial resolution in a way that the data can be correlated to provide improved image quality and to offer more complete biological evaluation for biomedical studies involving small animals. The project requires development of complete microSPECT and microCT subsystems. Both subsystems are configured with a shared gantry and animal bed with integrated instrumentation for data acquisition and system control. The microCT employs a microfocus X-ray tube and a CCD-based detector for low noise, high resolution imaging. The microSPECT utilizes three semiconductor detectors coupled with pinhole collimators. A significant contribution of this dissertation project is the development of iterative algorithms with geometrical compensation that allows radionuclide images to be reconstructed at submillimeter spatial resolution, but with significantly higher detection efficiency than conventional methods. Both subsystems are capable of helical scans, offering lengthened field of view and improved

  19. Design and evaluation of a mobile bedside PET/SPECT imaging system

    NASA Astrophysics Data System (ADS)

    Studenski, Matthew Thomas

    Patients confined to an intensive care unit, the emergency room, or a surgical suite are managed without nuclear medicine procedures such as positron emission tomography (PET) or single photon emission computed tomography (SPECT). These studies have diagnostic value which can greatly benefit the physician's treatment of the patient but require that the patient is moved to a scanner. This dissertation examines the feasibility of an economical PET/SPECT system that can be brought to the bedside of an immobile patient for imaging. We chose to focus on cardiac SPECT imaging including perfusion imaging using 99mTc tracers and viability imaging using 18F tracers first because of problems arising from positioning a detector beneath a patient's bed, a requirement for the opposed detector orientation in PET imaging. Second, SPECT imaging acquiring over the anterior 180 degrees of the patient results in reduced attenuation effects due to the heart's location in the anterior portion of the body. Four studies were done to assess the clinical feasibility of the mobile system; 1) the performance of the system was evaluated in SPECT mode at both 140 keV (99mTc tracers) and 511 keV (positron emitting tracers), 2) a dynamic cardiac phantom was used to develop and test image acquisition and processing methods for the system at both energies, 3) a high energy pinhole collimator was designed to reduce the effects of high energy photon penetration through the parallel hole collimator, and 4) we estimated the radiation dose to persons that would be in the vicinity of a patient to ensure that the effective dose is below the regulatory limit. With these studies, we show that the mobile system provides an economical means of bringing nuclear medicine to an immobile patient while staying below the regulatory dose limit to other persons. The system performed well at both 140 keV and 511 keV and provided viable images of a phantom myocardium at both energies. The system does not achieve the

  20. Segmentation and Visual Analysis of Whole-Body Mouse Skeleton microSPECT

    PubMed Central

    Khmelinskii, Artem; Groen, Harald C.; Baiker, Martin; de Jong, Marion; Lelieveldt, Boudewijn P. F.

    2012-01-01

    Whole-body SPECT small animal imaging is used to study cancer, and plays an important role in the development of new drugs. Comparing and exploring whole-body datasets can be a difficult and time-consuming task due to the inherent heterogeneity of the data (high volume/throughput, multi-modality, postural and positioning variability). The goal of this study was to provide a method to align and compare side-by-side multiple whole-body skeleton SPECT datasets in a common reference, thus eliminating acquisition variability that exists between the subjects in cross-sectional and multi-modal studies. Six whole-body SPECT/CT datasets of BALB/c mice injected with bone targeting tracers 99mTc-methylene diphosphonate (99mTc-MDP) and 99mTc-hydroxymethane diphosphonate (99mTc-HDP) were used to evaluate the proposed method. An articulated version of the MOBY whole-body mouse atlas was used as a common reference. Its individual bones were registered one-by-one to the skeleton extracted from the acquired SPECT data following an anatomical hierarchical tree. Sequential registration was used while constraining the local degrees of freedom (DoFs) of each bone in accordance to the type of joint and its range of motion. The Articulated Planar Reformation (APR) algorithm was applied to the segmented data for side-by-side change visualization and comparison of data. To quantitatively evaluate the proposed algorithm, bone segmentations of extracted skeletons from the correspondent CT datasets were used. Euclidean point to surface distances between each dataset and the MOBY atlas were calculated. The obtained results indicate that after registration, the mean Euclidean distance decreased from 11.5±12.1 to 2.6±2.1 voxels. The proposed approach yielded satisfactory segmentation results with minimal user intervention. It proved to be robust for “incomplete” data (large chunks of skeleton missing) and for an intuitive exploration and comparison of multi-modal SPECT/CT cross

  1. Evaluation of quantitative 90Y SPECT based on experimental phantom studies

    NASA Astrophysics Data System (ADS)

    Minarik, D.; Sjögreen Gleisner, K.; Ljungberg, M.

    2008-10-01

    In SPECT imaging of pure beta emitters, such as 90Y, the acquired spectrum is very complex, which increases the demands on the imaging protocol and the reconstruction. In this work, we have evaluated the quantitative accuracy of bremsstrahlung SPECT with focus on the reconstruction algorithm including model-based attenuation, scatter and collimator-detector response (CDR) compensations. The scatter and CDR compensation methods require pre-calculated point-spread functions, which were generated with the SIMIND MC program. The SIMIND program is dedicated for simulation of scintillation camera imaging and only handles photons. The aim of this work was therefore twofold. The first aim was to implement simulation of bremsstrahlung imaging into the SIMIND code and to validate simulations against experimental measurements. The second was to investigate the quality of bremsstrahlung SPECT imaging and to evaluate the possibility of quantifying the activity in differently shaped sources. In addition, a feasibility test was performed on a patient that underwent treatment with 90Y-Ibritumomab tiuxetan (Zevalin®). The MCNPX MC program was used to generate bremsstrahlung photon spectra which were used as source input in the SIMIND program. The obtained bremsstrahlung spectra were separately validated by experimental measurement using a HPGe detector. Validation of the SIMIND generated images was done by a comparison to gamma camera measurements of a syringe containing 90Y. Results showed a slight deviation between simulations and measurements in image regions outside the source, but the agreement was sufficient for the purpose of generating scatter and CDR kernels. For the bremsstrahlung SPECT experiment, the RSD torso phantom with 90Y in the liver insert was measured with and without background activities. Projection data were obtained using a GE VH/Hawkeye system. Image reconstruction was performed by using the OSEM algorithm with and without different combinations of model

  2. Operational radiation safety for PET-CT, SPECT-CT, and cyclotron facilities.

    PubMed

    Zanzonico, Pat; Dauer, Lawrence; St Germain, Jean

    2008-11-01

    Positron emission tomography (PET) and single-photon emission computed tomography (SPECT) are well- established and indispensable imaging modalities in modern medicine. State-of-the-art computed tomography (CT) scanners have now been integrated into multi-modality PET-CT and SPECT-CT devices, and these devices, particularly PET-CT scanners, are dramatically impacting clinical practice. 18F-fluorodeoxyglucose (FDG), by far the most widely used radiopharmaceutical for clinical PET imaging in general and oncologic PET imaging in particular, is highly accurate in detecting (approximately 90%) and staging many types of tumors, monitoring therapy response, and differentiating benign from malignant lesions. Several factors, including the relatively high administered activities [e.g., 370-740 MBq (10-20 mCi) of FDG], the high patient throughput (up to 30 patients per d), and in particular, the uniquely high energies (for a diagnostic setting) of the 511-keV positron-negatron annihilation photons, make shielding requirements, workflow, and other radiation protection issues important considerations in the design of a PET or PET-CT facility. The Report of Task Group 108 of the American Association of Physicists in Medicine (AAPM) provides a comprehensive summary of shielding design and related considerations, along with illustrative calculations. Whether in the form of a PET-CT or a SPECT-CT device, the introduction of CT scanners into a nuclear medicine setting has created new and complex radiation protection issues concerning the radiation burden and attendant risks accrued by patients undergoing such multi-modality procedures (especially in those instances in which higher-dose, diagnostic-quality CT studies are done as part of the PET-CT or SPECT-CT exam). In addition, because PET is dependent on the availability of short-lived 18F (Tp = 110 min) primarily in the form of FDG, and other short-lived positron emitters such as 11C (20 min), 13N (10 min), and 15O (2 min

  3. Clinical Value of 99Tcm-MDP SPECT Bone Scintigraphy in the Diagnosis of Unilateral Condylar Hyperplasia

    PubMed Central

    Wen, Bing; Shen, Ying; Wang, Chang-Yin

    2014-01-01

    Purpose. To investigate the clinical value of 99Tcm-MDP SPECT for the diagnosis of unilateral condylar hyperplasia (UCH). Methods. One hundred forty-nine patients who underwent mandibular 99Tcm-MDP SPECT between January 2009 and December 2012 were studied, including 105 cases that were clinically suspected of UCH and 44 comparable cases without UCH as a control group. Results. Increased bone activity was observed in the affected condyles for all UCH patients. In the UCH group, the relative percentage uptake on the affected side was 59% (SD ± 4.3%), significantly higher than the 41% (SD ± 4.1%) uptake on the contralateral side (P<0.001). Similarly, the condyle/skull ratio was significantly higher for the affected side (1.66 ± 0.63) than for the contralateral side (1.34 ± 0.34, P < 0.01. No significant difference was found in the control group between the left and right condyles. Values for the sensitivity (95%), specificity (61%), positive (84.4%) and negative (84.6%) predictive values, and accuracy (84.5%) for 99Tcm-MDP SPECT in the diagnosis of UCH were calculated. However, for the hyperplastic condyle, no correlation was observed between the thickness of each cartilage layer and the relative uptake in the SPECT image. Conclusion. 99Tcm-MDP SPECT is accurate for diagnosing UCH and can provide a reference for treatment options. PMID:24901015

  4. A new dual-isotope convolution cross-talk correction method: a Tl-201/Tc-99m SPECT cardiac phantom study.

    PubMed

    Knesaurek, K

    1994-10-01

    Simultaneous dual-isotope SPECT imaging provides a clear advantage in situations where two concurrent metabolic, anatomic, or background measurements are desired. It obviates the need for two separate imaging sessions, reduces patient motion problems, and provides exact image registration between images. However, a potential limitation of dual-isotope SPECT imaging is contribution of scattered and primary photons from one radionuclide into the second radionuclide's photopeak energy window, referred to here as cross-talk. Cross-talk in both photopeak energy windows can significantly degrade image quality, resolution, and quantitation to an unacceptable level. Simple cross-talk correction method used in dual-radionuclide in vitro counting, even applied on a pixel-by-pixel basis, does not account for the differences in spatial distribution of the photopeak and cross-talk photons. Here a new convolution cross-talk correction method is presented. The convolution filters are derived from point response functions (PRFs) for Tc-99m and Tl-201 point sources. Three separate acquisitions were performed, each with two 20% wide energy windows, one centered at 140 keV and another at 70 keV. The first acquisition was done with Tc-99m solution only, the second with Tl-201 solution only, and the third with a mixture of Tc-99m and Tl-201. The nonuniform RH-2 thorax-heart phantom was used to test a new correction technique. The main difficulty and limitation of the convolution correction approach is caused by the variation in PRF as a function of depth. Thus, average PRF should be used in the creation of an approximative filter.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7869989

  5. Atlas-driven scan planning for high-resolution micro-SPECT data acquisition based on multi-view photographs: a pilot study

    NASA Astrophysics Data System (ADS)

    Baiker, Martin; Vastenhouw, Brendan; Branderhorst, Woutjan; Reiber, Johan H. C.; Beekman, Freek; Lelieveldt, Boudewijn P. F.

    2009-02-01

    Highly focused Micro-SPECT scanners enable the acquisition of functional small animal data with very high-resolution. To acquire a maximum of emitted photons from a specific structure of interest and at the same time minimize the required acquisition time, typically only a small subvolume of the animal is scanned that contains the organs of interest. This Volume of Interest (VOI) can be defined manually based on photographs of the animal taken prior to SPECT scanning, for example two lateral views and a top view. In these photographs however, only the surface of the animal is visible and therefore visual estimation of the location of these organs may be difficult. In this paper, we propose a novel atlas-based technique for estimating the organ VOI for the major organs by mapping a small animal atlas to optical scout images. The user is required to outline the animal contour in one lateral view, and to mark two lateral landmarks in the top view photograph. These landmarks subsequently serve as fiducial landmarks to define a 3D Thin-Plate-Spline mapping of an anatomical mouse atlas to the photographic coordinate space. Planar projections of the mapped atlas organs on the photographs greatly facilitate the estimation of the size and position of the target organ. To validate the proposed approach, the estimated organ VOIs were compared to manually drawn organ outlines in a Micro-CT scan, which was co-registered to the scout photographs using physical landmarks. The results demonstrate a highly promising volume correspondence between the real and the estimated organ VOIs.

  6. The feasibility of using CT-guided ROI for semiquantifying striatal dopamine transporter availability in a hybrid SPECT/CT system.

    PubMed

    Hsu, Chien-Chin; Chang, Yen-Hsiang; Lin, Wei-Che; Tang, Shu-Wen; Wang, Pei-Wen; Huang, Yung-Cheng; Chiu, Nan-Tsing

    2014-01-01

    A hybrid SPECT/CT system provides accurate coregistration of functional and morphological images. CT-guided region of interest (ROI) for semiquantifying striatal dopamine transporter (DAT) availability may be a feasible method. We therefore assessed the intra- and interobserver reproducibility of manual SPECT and CT-guided ROI methods and compared their semiquantitative data with data from MRI-guided ROIs. We enrolled twenty-eight patients who underwent Tc-99m TRODAT-1 brain SPECT/CT and brain MRI. ROIs of the striatal, caudate, putamen, and occipital cortex were manually delineated on the SPECT, CT, and MRI. ROIs from CT and MRI were transferred to the coregistered SPECT for semiquantification. The striatal, caudate, and putamen nondisplaceable binding potential (BPND) were calculated. Using CT-guided ROIs had higher intra- and interobserver concordance correlation coefficients, closer Bland-Altman biases to zero, and narrower limits of agreement than using manual SPECT ROIs. The correlation coefficients of striatal, caudate, and putamen BPND were good between manual SPECT and MRI-guided ROI methods and even better between CT-guided and MRI-guided ROI methods. Conclusively, CT-guided ROI delineation for semiquantifying striatal DAT availability in a hybrid SPECT/CT system is highly reproducible, and the semiquantitative data correlate well with data from MRI-guided ROIs.

  7. Additional value of thallium-201 SPECT to a conventional exercise test for the identification of severe coronary lesions after an episode of unstable coronary artery disease.

    PubMed

    Karlsson, J E; Björkholm, A; Nylander, E; Ohlsson, J; Wallentin, L

    1995-06-01

    The additional value of thallium-201 SPECT to a conventional exercise test for the identification of patients with severe coronary lesions was evaluated in 170 men, one month after an episode of unstable coronary artery disease. Severe coronary lesions at coronary angiography--defined as three vessel disease, left main stenosis or proximal left anterior descending artery stenosis as part of two vessel disease--were observed in 45.9%. In the SPECT image, the left ventricular myocardium was divided into nine segments and each segment was classified as either normal (= 0), reduced uptake (= 1) or uptake defect (= 2). The sum of gradings in all segments post-exercise was denoted "SPECT score". The patients were divided into nine different groups regarding ST-depression during exercise (no ST-depression, ST-depression in 1-2 leads or > or = 3 leads) and "SPECT score" (no SPECT score, 1-3 scores or > or = 4 scores). Severe coronary lesions were, in 68% identified by SPECT score > or = 4 and in 65% by ST-depression in > or = 1 lead at exercise test. The specificity for identification of severe coronary lesions was, for both tests, 65%. SPECT score > or = 4 and/or ST-depression in > or = 3 leads identified 82% of the patients with severe coronary lesions with a specificity of 63%. Furthermore, SPECT score > or = 3 identified more patients with isolated proximal left anterior descending artery stenosis than ST-depression alone at exercise test.

  8. Comparison of SPECT/CT and MRI in Diagnosing Symptomatic Lesions in Ankle and Foot Pain Patients: Diagnostic Performance and Relation to Lesion Type

    PubMed Central

    Ha, Seunggyun; Hong, Sung Hwan; Paeng, Jin Chul; Lee, Dong Yeon; Cheon, Gi Jeong; Arya, Amitabh; Chung, June-Key; Lee, Dong Soo; Kang, Keon Wook

    2015-01-01

    Purpose The purpose of this study was to compare the diagnostic performance of SPECT/CT and MRI in patients with ankle and foot pain, with regard to the lesion types. Materials and Methods Fifty consecutive patients with ankle and foot pain, who underwent 99mTc-MDP SPECT/CT and MRI, were retrospectively enrolled in this study. Symptomatic lesions were determined based on clinical examination and response to treatment. On MRI and SPECT/CT, detected lesions were classified as bone, ligament/tendon, and joint lesions. Uptake on SPECT/CT was assessed using a 4-grade system. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of SPECT/CT and MRI were evaluated in all detected lesions and each lesion type. Diagnostic value of uptake grade was analyzed using receiver-operating characteristics (ROC) curve analysis, and diagnostic performance was compared using Chi-square or McNemar tests. Results In overall lesions, the sensitivity, PPV and NPV of SPECT/CT for symptomatic lesions were 93%, 56%, 91%, and they were 98%, 48%, 95% for MRI. There was no significant difference between SPECT/CT and MRI. However, the specificity of SPECT/CT was significantly higher than that of MRI (48% versus 24%, P = 0.016). Uptake grade on SPECT/CT was significantly higher in symptomatic lesions (P < 0.001), and its area under curve on ROC analysis was 0.787. In the analysis of each lesion type, the specificity of SPECT/CT was poor in joint lesions compared with other lesion types and MRI (P < 0.001, respectively). MRI exhibited lower specificity than SPECT/CT in bone lesions (P = 0.004) and ligament/tendon lesions (P < 0.001). Conclusions SPECT/CT has MRI-comparable diagnostic performance for symptomatic lesions in ankle and foot pain patients. SPECT/CT and MRI exhibit different diagnostic specificity in different lesion types. SPECT/CT may be used as a complementary imaging method to MRI for enhancing diagnostic specificity. PMID:25668182

  9. Investigation of hydrodynamic parameters in a draft tube reactor using radioisotope based techniques and conventional method.

    PubMed

    Jung, S H; Park, J G; Moon, J H; Kim, J B

    2015-07-01

    In this study, various techniques were attempted to investigate flow dynamics in the enclosed reactor and the results from the techniques were compared. Radioactive particle tracking (RPT) and industrial single photon emission computed tomography (SPECT) were carried out and the circulation times from them showed a deviation of 17.5%. The circulation time of the RPT was longer than that of SPECT, and it is speculated that the physical dimension of the/ fabricated radioactive particle creates the discrepancy. Particle image velocimetry (PIV) measurements and computational fluid dynamic (CFD) simulations were conducted. The velocity patterns from them were similar to each other in the entire reactor region except near the propeller installed at the bottom of the reactor. PMID:25867108

  10. High-Resolution 4D Imaging of Technetium Transport in Porous Media using Preclinical SPECT-CT

    NASA Astrophysics Data System (ADS)

    Dogan, M.; DeVol, T. A.; Groen, H.; Moysey, S. M.; Ramakers, R.; Powell, B. A.

    2015-12-01

    Preclinical SPECT-CT (single-photon emission computed tomography with integrated X-ray computed tomography) offers the potential to quantitatively image the dynamic three-dimensional distribution of radioisotopes with sub-millimeter resolution, overlaid with structural CT images (20-200 micron resolution), making this an attractive method for studying transport in porous media. A preclinical SPECT-CT system (U-SPECT4CT, MILabs BV. Utrecht, The Netherlands) was evaluated for imaging flow and transport of 99mTc (t1/2=6hrs) using a 46,5mm by 156,4mm column packed with individual layers consisting of <0.2mm diameter silica gel, 0.2-0.25, 0.5, 1.0, 2.0, 3.0, and 4.0mm diameter glass beads, and a natural soil sample obtained from the Savannah River Site. The column was saturated with water prior to injecting the 99mTc solution. During the injection the flow was interrupted intermittently for 10 minute periods to allow for the acquisition of a SPECT image of the transport front. Non-uniformity of the front was clearly observed in the images as well as the retarded movement of 99mTc in the soil layer. The latter is suggesting good potential for monitoring transport processes occurring on the timescale of hours. After breakthrough of 99mTc was achieved, the flow was stopped and SPECT data were collected in one hour increments to evaluate the sensitivity of the instrument as the isotope decayed. Fused SPECT- CT images allowed for improved interpretation of 99mTc distributions within individual pore spaces. With ~3 MBq remaining in the column, the lowest activity imaged, it was not possible to clearly discriminate any of the pore spaces.

  11. Real-time cine and myocardial perfusion with treadmill exercise stress cardiovascular magnetic resonance in patients referred for stress SPECT

    PubMed Central

    2010-01-01

    Background To date, stress cardiovascular magnetic resonance (CMR) has relied on pharmacologic agents, and therefore lacked the physiologic information available only with exercise stress. Methods 43 patients age 25 to 81 years underwent a treadmill stress test incorporating both Tc99m SPECT and CMR. After rest Tc99m SPECT imaging, patients underwent resting cine CMR. Patients then underwent in-room exercise stress using a partially modified treadmill. 12-lead ECG monitoring was performed throughout. At peak stress, Tc99m was injected and patients rapidly returned to their prior position in the magnet for post-exercise cine and perfusion imaging. The patient table was pulled out of the magnet for recovery monitoring. The patient was sent back into the magnet for recovery cine and resting perfusion followed by delayed post-gadolinium imaging. Post-CMR, patients went to the adjacent SPECT lab to complete stress nuclear imaging. Each modality's images were reviewed blinded to the other's results. Results Patients completed on average 9.3 ± 2.4 min of the Bruce protocol. Stress cine CMR was completed in 68 ± 14 sec following termination of exercise, and stress perfusion CMR was completed in 88 ± 8 sec. Agreement between SPECT and CMR was moderate (κ = 0.58). Accuracy in eight patients who underwent coronary angiography was 7/8 for CMR and 5/8 for SPECT (p = 0.625). Follow-up at 6 months indicated freedom from cardiovascular events in 29/29 CMR-negative and 33/34 SPECT-negative patients. Conclusions Exercise stress CMR including wall motion and perfusion is feasible in patients with suspected ischemic heart disease. Larger clinical trials are warranted based on the promising results of this pilot study to allow comparative effectiveness studies of this stress imaging system vs. other stress imaging modalities. PMID:20624294

  12. Optimization of SPECT-CT Hybrid Imaging Using Iterative Image Reconstruction for Low-Dose CT: A Phantom Study

    PubMed Central

    Grosser, Oliver S.; Kupitz, Dennis; Ruf, Juri; Czuczwara, Damian; Steffen, Ingo G.; Furth, Christian; Thormann, Markus; Loewenthal, David; Ricke, Jens; Amthauer, Holger

    2015-01-01

    Background Hybrid imaging combines nuclear medicine imaging such as single photon emission computed tomography (SPECT) or positron emission tomography (PET) with computed tomography (CT). Through this hybrid design, scanned patients accumulate radiation exposure from both applications. Imaging modalities have been the subject of long-term optimization efforts, focusing on diagnostic applications. It was the aim of this study to investigate the influence of an iterative CT image reconstruction algorithm (ASIR) on the image quality of the low-dose CT images. Methodology/Principal Findings Examinations were performed with a SPECT-CT scanner with standardized CT and SPECT-phantom geometries and CT protocols with systematically reduced X-ray tube currents. Analyses included image quality with respect to photon flux. Results were compared to the standard FBP reconstructed images. The general impact of the CT-based attenuation maps used during SPECT reconstruction was examined for two SPECT phantoms. Using ASIR for image reconstructions, image noise was reduced compared to FBP reconstructions for the same X-ray tube current. The Hounsfield unit (HU) values reconstructed by ASIR were correlated to the FBP HU values(R2 ≥ 0.88) and the contrast-to-noise ratio (CNR) was improved by ASIR. However, for a phantom with increased attenuation, the HU values shifted for low X-ray tube currents I ≤ 60 mA (p ≤ 0.04). In addition, the shift of the HU values was observed within the attenuation corrected SPECT images for very low X-ray tube currents (I ≤ 20 mA, p ≤ 0.001). Conclusion/Significance In general, the decrease in X-ray tube current up to 30 mA in combination with ASIR led to a reduction of CT-related radiation exposure without a significant decrease in image quality. PMID:26390216

  13. Radionuclide 131I-labeled multifunctional dendrimers for targeted SPECT imaging and radiotherapy of tumors

    NASA Astrophysics Data System (ADS)

    Zhu, Jingyi; Zhao, Lingzhou; Cheng, Yongjun; Xiong, Zhijuan; Tang, Yueqin; Shen, Mingwu; Zhao, Jinhua; Shi, Xiangyang

    2015-10-01

    We report the synthesis, characterization, and utilization of radioactive 131I-labeled multifunctional dendrimers for targeted single-photon emission computed tomography (SPECT) imaging and radiotherapy of tumors. In this study, amine-terminated poly(amidoamine) dendrimers of generation 5 (G5.NH2) were sequentially modified with 3-(4'-hydroxyphenyl)propionic acid-OSu (HPAO) and folic acid (FA) linked with polyethylene glycol (PEG), followed by acetylation modification of the dendrimer remaining surface amines and labeling of radioactive iodine-131 (131I). The generated multifunctional 131I-G5.NHAc-HPAO-PEG-FA dendrimers were characterized via different methods. We show that prior to 131I labeling, the G5.NHAc-HPAO-PEG-FA dendrimers conjugated with approximately 9.4 HPAO moieties per dendrimer are noncytotoxic at a concentration up to 20 μM and are able to target cancer cells overexpressing FA receptors (FAR), thanks to the modified FA ligands. In the presence of a phenol group, radioactive 131I is able to be efficiently labeled onto the dendrimer platform with good stability and high radiochemical purity, and render the platform with an ability for targeted SPECT imaging and radiotherapy of an FAR-overexpressing xenografted tumor model in vivo. The designed strategy to use the facile dendrimer nanotechnology may be extended to develop various radioactive theranostic nanoplatforms for targeted SPECT imaging and radiotherapy of different types of cancer.We report the synthesis, characterization, and utilization of radioactive 131I-labeled multifunctional dendrimers for targeted single-photon emission computed tomography (SPECT) imaging and radiotherapy of tumors. In this study, amine-terminated poly(amidoamine) dendrimers of generation 5 (G5.NH2) were sequentially modified with 3-(4'-hydroxyphenyl)propionic acid-OSu (HPAO) and folic acid (FA) linked with polyethylene glycol (PEG), followed by acetylation modification of the dendrimer remaining surface amines and

  14. Whole-body (99m)Tc-octreotide scintigraphy with SPECT/CT to detect occult tumor inducing paraneoplastic osteomalacia.

    PubMed

    Rodrigues, Napoleão Ramalho; Calich, Ana Luisa; Etchebehere, Mauricio; Ichiki, Wilson Andre; Pereira, Fabio Payao; Amstalden, Elaine Maria Ingrid; de Sa Etchebehere, Elba Cristina

    2015-01-01

    A 32-year-old woman presented with progressive myalgia, bone pain, fatigue, insufficiency hip fractures, high urine phosphate, and low serum phosphate and vitamin D levels. These findings were suggestive of oncogenic osteomalacia. A whole-body Tc-octreotide scintigraphy with SPECT/CT showed uptake on a sclerotic intramedullary lesion in the left medial tibia plateau. MRI depicted a solid lesion. The lesion was surgically removed; the patient became asymptomatic, and follow-up laboratory results normalized. Histopathologic examination revealed a vascular hemangiopericytoma-like tumor, positive for somatostatin receptor (SSR-2). Whole-body Tc-octreotide scintigraphy with SPECT/CT may detect occult oncogenic osteomalacia tumors.

  15. Detection of melorheostosis in a young lady with upper limb pain on Three Phase Bone Scintigram/SPECT-CT.

    PubMed

    Hassan, Aamna; Khalid, Madeeha; Khawar, Saquib

    2016-01-01

    Melorheostosis is a benign, noninheritable bone dysplasia characterized by its classic radiographic features of dense, flowing hyperostosis. It frequently affects one limb, usually the lower extremity and rarely the axial skeleton. A 26-year-old lady with obesity, polycystic ovarian syndrome and scalp dandruff presented with a long standing history of upper extremity pain and inability to adduct the arm completely. A Tc-99m MDP whole body and SPECT/CT scan performed for suspected fibrous dysplasia showed increased radiotracer uptake in densely sclerotic humeral and radial melorheostosis. This case highlighted the role of SPECT/CT imaging in this rare condition. PMID:27252746

  16. Detection of melorheostosis in a young lady with upper limb pain on Three Phase Bone Scintigram/SPECT-CT

    PubMed Central

    Hassan, Aamna; Khalid, Madeeha; Khawar, Saquib

    2016-01-01

    Summary Melorheostosis is a benign, noninheritable bone dysplasia characterized by its classic radiographic features of dense, flowing hyperostosis. It frequently affects one limb, usually the lower extremity and rarely the axial skeleton. A 26-year-old lady with obesity, polycystic ovarian syndrome and scalp dandruff presented with a long standing history of upper extremity pain and inability to adduct the arm completely. A Tc-99m MDP whole body and SPECT/CT scan performed for suspected fibrous dysplasia showed increased radiotracer uptake in densely sclerotic humeral and radial melorheostosis. This case highlighted the role of SPECT/CT imaging in this rare condition. PMID:27252746

  17. Myocardial perfusion imaging with technetium-99m sestamibi SPECT in the evaluation of coronary artery disease

    SciTech Connect

    Maddahi, J.; Kiat, H.; Van Train, K.F.; Prigent, F.; Friedman, J.; Garcia, E.V.; Alazraki, N.; DePuey, E.G.; Nichols, K.; Berman, D.S. )

    1990-10-16

    Technetium-99m (Tc-99m) sestamibi is a new myocardial perfusion imaging agent that offers significant advantages over thallium-201 (Tl-201) for myocardial perfusion imaging. The results of the current clinical trials using acquisition and processing parameters similar to those for Tl-201 and a separate (2-day) injection protocol suggest that Tc-99m sestamibi and Tl-201 single photon emission computed tomography (SPECT) provide similar information with respect to detection of myocardial perfusion defects, assessment of the pattern of defect reversibility, overall detection of coronary artery disease (CAD) and detection of disease in individual coronary arteries. Tc-99m sestamibi SPECT appears to be superior to Tc-99m sestamibi planar imaging because the former provides a higher defect contrast and is more accurate for detection of disease in individual coronary arteries. Research is currently under way addressing optimization of acquisition and processing of Tc-99m sestamibi studies and development of quantitative algorithms for detection and localization of CAD and sizing of transmural and nontransmural myocardial perfusion defects. It is expected that with the implementation of the final results of these new developments, further significant improvement in image quality will be attained, which in turn will further increase the confidence in image interpretation. Development of algorithms for analysis of end-diastolic myocardial images may allow better evaluation of small and nontransmural myocardial defects. Furthermore, gated studies may provide valuable information with respect to regional myocardial wall motion and wall thickening. With the implementation of algorithms for attenuation and scatter correction, the overall specificity of Tc-99m sestamibi SPECT should improve significantly. 32 references.

  18. Gold nanoparticles-based SPECT/CT imaging probe targeting for vulnerable atherosclerosis plaques.

    PubMed

    Li, Xiao; Wang, Cong; Tan, Hui; Cheng, Leilei; Liu, Guobing; Yang, Yi; Zhao, Yanzhao; Zhang, Yiqiu; Li, Yanli; Zhang, Chunfu; Xiu, Yan; Cheng, Dengfeng; Shi, Hongcheng

    2016-11-01

    In order to realize accurate localization and precise evaluation of vulnerability of atherosclerotic plaques via dual-modal imaging, gold nanoparticles (GNPs) were firstly caped with a thin amino-PEGs cover and then conjugated with the targeting molecular Annexin V and radionuclide Tc-99m simultaneously to form SPECT/CT imaging probe targeting apoptotic macrophages. The as-synthesized (99m)Tc-GNPs-Annexin V was with uniform size (30.2 ± 2.9 nm) and high labeling rate (98.9 ± 0.5%) and stability. Targeting ability of Annexin V for apoptotic macrophages was kept and enhanced. For macrophages with 30% apoptosis, cellular uptakes of 3.52 ± 0.35% for (99m)Tc-GNPs-Annexin V, 2.41 ± 0.53% for (99m)Tc-GNPs and 1.68 ± 0.36% for (99m)Tc-Annexin V were achieved after 2 h incubation. ApoE knock out mice with high fat diet-induced atherosclerosis were scanned via (99m)Tc-GNPs-Annexin V SPECT/CT. With the introduction of targeting molecules, imaging probe was more efficient in accumulating in apoptotic macrophages. In practical evaluation, CT helps to restrict the lesions depiction more accurately, meanwhile, SPECT imaging intensity correlated with pathological changes tightly. In conclusion, Annexin V-modified hybrid gold nanoparticles were successfully synthesized, and this imaging system helped to better localize and diagnose those vulnerable AS plaques via specific targeting the apoptotic macrophages.

  19. In vivo mapping of cholinergic neurons in the human brain using SPECT and IBVM

    SciTech Connect

    Kuhl, D.E.; Koeppe, R.A.; Fessler, J.A.

    1994-03-01

    In the search for an in vivo marker of cholinergic neuronal integrity, the authors extended to human use the tracer (-)-5-[{sup 123}I]iodobenzovesamicol (IBVM)). IBVM, an analog of vesamicol that binds to the acetylcholine transporter on presynaptic vesicles, was prepared with specific activity greater than 1.11 x 10{sup 9} MBq mmole{sup {minus}1}. After intravenous injection of [{sup 123}I]IBVM, body distribution studies (n = 5) and brain SPECT studies (n = 5) were performed on normal human subjects (n = 10). SPECT images of the brain were collected sequentially over the first 4.5 hr following injection, and again 18 hr later. Data were realigned and transformed to stereotaxic coordinates, and localized activities were extracted for tracer kinetic analysis. The cerebral tracer input function was determined from metabolite-corrected radial arterial blood samples. The best data fit was obtained using a three-compartment model, including terms reflecting cerebral blood volume, exchange of free tracer between plasma and brain and specific binding. Dissociation of bound tracer was negligible for up to 4 hr. For the fitted parameters reflecting transport (K{sub 1}) and binding site density index (k{sub 3}, co-efficients of variation were approximately 8% in cortical regions of interest. Relative distributions corresponded well with post-mortem immunohistochemical values reported for the acetylcholine-synthesizing enzyme choline acetyltransferase, k{sub 3} (IBVM binding site density index), and tracer activity distribution at 22 hr, but not at 4 hr after injection. SPECT imaging of [{sup 123}I]IBVM succeeds as an in vivo measure of cholinergic neuronal integrity and should be useful for the study of cerebral degenerative processes such as Alzheimer`s disease. 24 refs., 4 figs., 3 tabs.

  20. Gold nanoparticles-based SPECT/CT imaging probe targeting for vulnerable atherosclerosis plaques.

    PubMed

    Li, Xiao; Wang, Cong; Tan, Hui; Cheng, Leilei; Liu, Guobing; Yang, Yi; Zhao, Yanzhao; Zhang, Yiqiu; Li, Yanli; Zhang, Chunfu; Xiu, Yan; Cheng, Dengfeng; Shi, Hongcheng

    2016-11-01

    In order to realize accurate localization and precise evaluation of vulnerability of atherosclerotic plaques via dual-modal imaging, gold nanoparticles (GNPs) were firstly caped with a thin amino-PEGs cover and then conjugated with the targeting molecular Annexin V and radionuclide Tc-99m simultaneously to form SPECT/CT imaging probe targeting apoptotic macrophages. The as-synthesized (99m)Tc-GNPs-Annexin V was with uniform size (30.2 ± 2.9 nm) and high labeling rate (98.9 ± 0.5%) and stability. Targeting ability of Annexin V for apoptotic macrophages was kept and enhanced. For macrophages with 30% apoptosis, cellular uptakes of 3.52 ± 0.35% for (99m)Tc-GNPs-Annexin V, 2.41 ± 0.53% for (99m)Tc-GNPs and 1.68 ± 0.36% for (99m)Tc-Annexin V were achieved after 2 h incubation. ApoE knock out mice with high fat diet-induced atherosclerosis were scanned via (99m)Tc-GNPs-Annexin V SPECT/CT. With the introduction of targeting molecules, imaging probe was more efficient in accumulating in apoptotic macrophages. In practical evaluation, CT helps to restrict the lesions depiction more accurately, meanwhile, SPECT imaging intensity correlated with pathological changes tightly. In conclusion, Annexin V-modified hybrid gold nanoparticles were successfully synthesized, and this imaging system helped to better localize and diagnose those vulnerable AS plaques via specific targeting the apoptotic macrophages. PMID:27619241

  1. Abdominal Aortic Aneurysms Targeted by Functionalized Polysaccharide Microparticles: a new Tool for SPECT Imaging

    PubMed Central

    Bonnard, Thomas; Yang, Gonord; Petiet, Anne; Ollivier, Véronique; Haddad, Oualid; Arnaud, Denis; Louedec, Liliane; Bachelet-Violette, Laure; Derkaoui, Sidi Mohammed; Letourneur, Didier; Chauvierre, Cedric; Le Visage, Catherine

    2014-01-01

    Aneurysm diagnostic is nowadays limited by the lack of technology that enables early detection and rupture risk prediction. New non invasive tools for molecular imaging are still required. In the present study, we present an innovative SPECT diagnostic tool for abdominal aortic aneurysm (AAA) produced from injectable polysaccharide microparticles radiolabeled with technetium 99m (99mTc) and functionalized with fucoidan, a sulfated polysaccharide with the ability to target P-Selectin. P-Selectin is a cell adhesion molecule expressed on activated endothelial cells and platelets which can be found in the thrombus of aneurysms, as well as in other vascular pathologies. Microparticles with a maximum hydrodynamic diameter of 4 µm were obtained by crosslinking the polysaccharides dextran and pullulan. They were functionalized with fucoidan. In vitro interactions with human activated platelets were assessed by flow cytometry that demonstrated a specific affinity of fucoidan functionalized microparticles for P-Selectin expressed by activated platelets. For in vivo AAA imaging, microparticles were radiolabeled with 99mTc and intravenously injected into healthy and AAA rats obtained by elastase perfusion through the aorta wall. Animals were scanned by SPECT imaging. A strong contrast enhancement located in the abdominal aorta of AAA rats was obtained, while no signal was obtained in healthy rats or in AAA rats after injection of non-functionalized control microparticles. Histological studies revealed that functionalized radiolabeled polysaccharide microparticles were localized in the AAA wall, in the same location where P-Selectin was expressed. These microparticles therefore constitute a promising SPECT imaging tool for AAA and potentially for other vascular diseases characterized by P-Selectin expression. Future work will focus on validating the efficiency of the microparticles to diagnose these other pathologies and the different stages of AAA. Incorporation of a

  2. Quantitative capabilities of four state-of-the-art SPECT-CT cameras

    PubMed Central

    2012-01-01

    Background Four state-of-the-art single-photon emission computed tomography-computed tomography (SPECT-CT) systems, namely Philips Brightview, General Electric Discovery NM/CT 670 and Infinia Hawkeye 4, and Siemens Symbia T6, were investigated in terms of accuracy of attenuation and scatter correction, contrast recovery for small hot and cold structures, and quantitative capabilities when using their dedicated three-dimensional iterative reconstruction with attenuation and scatter corrections and resolution recovery. Methods The National Electrical Manufacturers Association (NEMA) NU-2 1994 phantom with cold air, water, and Teflon inserts, and a homemade contrast phantom with hot and cold rods were filled with 99mTc and scanned. The acquisition parameters were chosen to provide adequate linear and angular sampling and high count statistics. The data were reconstructed using Philips Astonish, General Electric Evolution for Bone, or Siemens Flash3D, eight subsets, and a varying number of iterations. A procedure similar to the one used in positron emission tomography (PET) allowed us to obtain the factor to convert counts per pixel into activity per unit volume. Results Edge and oscillation artifacts were observed with all phantoms and all systems. At 30 iterations, the residual fraction in the inserts of the NEMA phantom fell below 3.5%. Contrast recovery increased with the number of iterations but became almost saturated at 24 iterations onwards. In the uniform part of the NEMA and contrast phantoms, a quantification error below 10% was achieved. Conclusions In objects whose dimensions exceeded the SPECT spatial resolution by several times, quantification seemed to be feasible within 10% error limits. A partial volume effect correction strategy remains necessary for the smallest structures. The reconstruction artifacts nevertheless remain a handicap on the road towards accurate quantification in SPECT and should be the focus of further works in reconstruction

  3. Characterisation of radioiodinated flavonoid derivatives for SPECT imaging of cerebral prion deposits.

    PubMed

    Fuchigami, Takeshi; Yamashita, Yuki; Kawasaki, Masao; Ogawa, Ayaka; Haratake, Mamoru; Atarashi, Ryuichiro; Sano, Kazunori; Nakagaki, Takehiro; Ubagai, Kaori; Ono, Masahiro; Yoshida, Sakura; Nishida, Noriyuki; Nakayama, Morio

    2015-01-01

    Prion diseases are fatal neurodegenerative diseases characterised by deposition of amyloid plaques containing abnormal prion protein aggregates (PrP(Sc)). This study aimed to evaluate the potential of radioiodinated flavonoid derivatives for single photon emission computed tomography (SPECT) imaging of PrP(Sc). In vitro binding assays using recombinant mouse PrP (rMoPrP) aggregates revealed that the 4-dimethylamino-substituted styrylchromone derivative (SC-NMe2) had higher in vitro binding affinity (Kd = 24.5 nM) and capacity (Bmax = 36.3 pmol/nmol protein) than three other flavonoid derivatives (flavone, chalcone, and aurone). Fluorescent imaging using brain sections from mouse-adapted bovine spongiform encephalopathy (mBSE)-infected mice demonstrated that SC-NMe2 clearly labelled PrP(Sc)-positive prion deposits in the mice brain. Two methoxy SC derivatives, SC-OMe and SC-(OMe)2, also showed high binding affinity for rMoPrP aggregates with Ki values of 20.8 and 26.6 nM, respectively. In vitro fluorescence and autoradiography experiments demonstrated high accumulation of [(125)I]SC-OMe and [(125)I]SC-(OMe)2 in prion deposit-rich regions of the mBSE-infected mouse brain. SPECT/computed tomography (CT) imaging and ex vivo autoradiography demonstrated that [(123)I]SC-OMe showed consistent brain distribution with the presence of PrP(Sc) deposits in the mBSE-infected mice brain. In conclusion, [(123)I]SC-OMe appears a promising SPECT radioligand for monitoring prion deposit levels in the living brain. PMID:26669576

  4. Characterisation of radioiodinated flavonoid derivatives for SPECT imaging of cerebral prion deposits

    PubMed Central

    Fuchigami, Takeshi; Yamashita, Yuki; Kawasaki, Masao; Ogawa, Ayaka; Haratake, Mamoru; Atarashi, Ryuichiro; Sano, Kazunori; Nakagaki, Takehiro; Ubagai, Kaori; Ono, Masahiro; Yoshida, Sakura; Nishida, Noriyuki; Nakayama, Morio

    2015-01-01

    Prion diseases are fatal neurodegenerative diseases characterised by deposition of amyloid plaques containing abnormal prion protein aggregates (PrPSc). This study aimed to evaluate the potential of radioiodinated flavonoid derivatives for single photon emission computed tomography (SPECT) imaging of PrPSc. In vitro binding assays using recombinant mouse PrP (rMoPrP) aggregates revealed that the 4-dimethylamino-substituted styrylchromone derivative (SC-NMe2) had higher in vitro binding affinity (Kd = 24.5 nM) and capacity (Bmax = 36.3 pmol/nmol protein) than three other flavonoid derivatives (flavone, chalcone, and aurone). Fluorescent imaging using brain sections from mouse-adapted bovine spongiform encephalopathy (mBSE)-infected mice demonstrated that SC-NMe2 clearly labelled PrPSc-positive prion deposits in the mice brain. Two methoxy SC derivatives, SC-OMe and SC-(OMe)2, also showed high binding affinity for rMoPrP aggregates with Ki values of 20.8 and 26.6 nM, respectively. In vitro fluorescence and autoradiography experiments demonstrated high accumulation of [125I]SC-OMe and [125I]SC-(OMe)2 in prion deposit-rich regions of the mBSE-infected mouse brain. SPECT/computed tomography (CT) imaging and ex vivo autoradiography demonstrated that [123I]SC-OMe showed consistent brain distribution with the presence of PrPSc deposits in the mBSE-infected mice brain. In conclusion, [123I]SC-OMe appears a promising SPECT radioligand for monitoring prion deposit levels in the living brain. PMID:26669576

  5. Macrocyclic polyaminocarboxylates for stable radiometal antibody conjugates for therapy, spect and pet imaging

    DOEpatents

    Mease, Ronnie C.; Mausner, Leonard F.; Srivastava, Suresh C.

    1997-06-17

    A simple method for the synthesis of 1,4,7, 10-tetraazacyclododecane N,N'N",N'"-tetraacetic acid and 1,4,8,11-tetraazacyclotetradecane N,N',N",N'"-tetraacetic acid involves cyanomethylating 1,4,7, 10-tetraazacyclododecane or 1,4,8,11-tetraazacyclotetradecane to form a tetranitrile and hydrolyzing the tetranitrile. These macrocyclic compounds are functionalized through one of the carboxylates and then conjugated to various biological molecules including monoclonal antibodies. The resulting conjugated molecules are labeled with radiometals for SPECT and PET imaging and for radiotherapy.

  6. Correction for collimator-detector response in SPECT using point spread function template.

    PubMed

    Chun, Se Young; Fessler, Jeffrey A; Dewaraja, Yuni K

    2013-02-01

    Compensating for the collimator-detector response (CDR) in SPECT is important for accurate quantification. The CDR consists of both a geometric response and a septal penetration and collimator scatter response. The geometric response can be modeled analytically and is often used for modeling the whole CDR if the geometric response dominates. However, for radionuclides that emit medium or high-energy photons such as I-131, the septal penetration and collimator scatter response is significant and its modeling in the CDR correction is important for accurate quantification. There are two main methods for modeling the depth-dependent CDR so as to include both the geometric response and the septal penetration and collimator scatter response. One is to fit a Gaussian plus exponential function that is rotationally invariant to the measured point source response at several source-detector distances. However, a rotationally-invariant exponential function cannot represent the star-shaped septal penetration tails in detail. Another is to perform Monte-Carlo (MC) simulations to generate the depth-dependent point spread functions (PSFs) for all necessary distances. However, MC simulations, which require careful modeling of the SPECT detector components, can be challenging and accurate results may not be available for all of the different SPECT scanners in clinics. In this paper, we propose an alternative approach to CDR modeling. We use a Gaussian function plus a 2-D B-spline PSF template and fit the model to measurements of an I-131 point source at several distances. The proposed PSF-template-based approach is nearly non-parametric, captures the characteristics of the septal penetration tails, and minimizes the difference between the fitted and measured CDR at the distances of interest. The new model is applied to I-131 SPECT reconstructions of experimental phantom measurements, a patient study, and a MC patient simulation study employing the XCAT phantom. The proposed model

  7. Accuracy of partial volume effect correction in clinical molecular imaging of dopamine transporter using SPECT

    NASA Astrophysics Data System (ADS)

    Soret, Marine; Alaoui, Jawad; Koulibaly, Pierre M.; Darcourt, Jacques; Buvat, Irène

    2007-02-01

    ObjectivesPartial volume effect (PVE) is a major source of bias in brain SPECT imaging of dopamine transporter. Various PVE corrections (PVC) making use of anatomical data have been developed and yield encouraging results. However, their accuracy in clinical data is difficult to demonstrate because the gold standard (GS) is usually unknown. The objective of this study was to assess the accuracy of PVC. MethodTwenty-three patients underwent MRI and 123I-FP-CIT SPECT. The binding potential (BP) values were measured in the striata segmented on the MR images after coregistration to SPECT images. These values were calculated without and with an original PVC. In addition, for each patient, a Monte Carlo simulation of the SPECT scan was performed. For these simulations where true simulated BP values were known, percent biases in BP estimates were calculated. For the real data, an evaluation method that simultaneously estimates the GS and a quadratic relationship between the observed and the GS values was used. It yields a surrogate mean square error (sMSE) between the estimated values and the estimated GS values. ResultsThe averaged percent difference between BP measured for real and for simulated patients was 0.7±9.7% without PVC and was -8.5±14.5% with PVC, suggesting that the simulated data reproduced the real data well enough. For the simulated patients, BP was underestimated by 66.6±9.3% on average without PVC and overestimated by 11.3±9.5% with PVC, demonstrating the greatest accuracy of BP estimates with PVC. For the simulated data, sMSE were 27.3 without PVC and 0.90 with PVC, confirming that our sMSE index properly captured the greatest accuracy of BP estimates with PVC. For the real patient data, sMSE was 50.8 without PVC and 3.5 with PVC. These results were consistent with those obtained on the simulated data, suggesting that for clinical data, and despite probable segmentation and registration errors, BP were more accurately estimated with PVC than without

  8. Measuring the proton spectrum in neutron decay—Latest results with aSPECT

    NASA Astrophysics Data System (ADS)

    Simson, M.; Ayala Guardia, F.; Baeßler, S.; Borg, M.; Glück, F.; Heil, W.; Konorov, I.; Konrad, G.; Muñoz Horta, R.; Leung, K. K. H.; Sobolev, Yu.; Soldner, T.; Wirth, H.-F.; Zimmer, O.

    2009-12-01

    The retardation spectrometer aSPECT was built to measure the shape of the proton spectrum in free neutron decay with high precision. This allows us to determine the antineutrino electron angular correlation coefficient a. We aim for a precision more than one order of magnitude better than the present best value, which is Δa/a=5%. In a recent beam time performed at the Institut Laue-Langevin during April/May 2008 we reached a statistical accuracy of about 2% per 24 h measurement time. Several systematic effects were investigated experimentally. We expect the total relative uncertainty to be well below 5%.

  9. Spatially resolved assessment of hepatic function using 99mTc-IDA SPECT

    SciTech Connect

    Wang, Hesheng; Cao, Yue

    2013-09-15

    Purpose: 99mTc-iminodiacetic acid (IDA) hepatobiliary imaging is usually quantified for hepatic function on the entire liver or regions of interest (ROIs) in the liver. The authors presented a method to estimate the hepatic extraction fraction (HEF) voxel-by-voxel from single-photon emission computed tomography (SPECT)/CT with a 99mTc-labeled IDA agent of mebrofenin and evaluated the spatially resolved HEF measurements with an independent physiological measurement.Methods: Fourteen patients with intrahepatic cancers were treated with radiation therapy (RT) and imaged by 99mTc-mebrofenin SPECT before and 1 month after RT. The dynamic SPECT volumes were with a resolution of 3.9 × 3.9 × 2.5 mm{sup 3}. Throughout the whole liver with approximate 50 000 voxels, voxelwise HEF quantifications were estimated and compared between using arterial input function (AIF) from the heart and using vascular input function (VIF) from the spleen. The correlation between mean of the HEFs over the nontumor liver tissue and the overall liver function measured by Indocyanine green clearance half-time (T1/2) was assessed. Variation of the voxelwise estimation was evaluated in ROIs drawn in relatively homogeneous regions of the livers. The authors also examined effects of the time range parameter on the voxelwise HEF quantification.Results: Mean of the HEFs over the liver estimated using AIF significantly correlated with the physiological measurement T1/2 (r= 0.52, p= 0.0004), and the correlation was greatly improved by using VIF (r= 0.79, p < 0.0001). The parameter of time range for the retention phase did not lead to a significant difference in the means of the HEFs in the ROIs. Using VIF and a retention phase time range of 7–30 min, the relative variation of the voxelwise HEF in the ROIs was 10%± 6% of respective mean HEF.Conclusions: The voxelwise HEF derived from 99mTc-IDA SPECT by the deconvolution analysis is feasible to assess the spatial distribution of hepatic function in the

  10. Reliability evaluation of I-123 ADAM SPECT imaging using SPM software and AAL ROI methods

    NASA Astrophysics Data System (ADS)

    Yang, Bang-Hung; Tsai, Sung-Yi; Wang, Shyh-Jen; Su, Tung-Ping; Chou, Yuan-Hwa; Chen, Chia-Chieh; Chen, Jyh-Cheng

    2011-08-01

    The level of serotonin was regulated by serotonin transporter (SERT), which is a decisive protein in regulation of serotonin neurotransmission system. Many psychiatric disorders and therapies were also related to concentration of cerebral serotonin. I-123 ADAM was the novel radiopharmaceutical to image SERT in brain. The aim of this study was to measure reliability of SERT densities of healthy volunteers by automated anatomical labeling (AAL) method. Furthermore, we also used statistic parametric mapping (SPM) on a voxel by voxel analysis to find difference of cortex between test and retest of I-123 ADAM single photon emission computed tomography (SPECT) images.Twenty-one healthy volunteers were scanned twice with SPECT at 4 h after intravenous administration of 185 MBq of 123I-ADAM. The image matrix size was 128×128 and pixel size was 3.9 mm. All images were obtained through filtered back-projection (FBP) reconstruction algorithm. Region of interest (ROI) definition was performed based on the AAL brain template in PMOD version 2.95 software package. ROI demarcations were placed on midbrain, pons, striatum, and cerebellum. All images were spatially normalized to the SPECT MNI (Montreal Neurological Institute) templates supplied with SPM2. And each image was transformed into standard stereotactic space, which was matched to the Talairach and Tournoux atlas. Then differences across scans were statistically estimated on a voxel by voxel analysis using paired t-test (population main effect: 2 cond's, 1 scan/cond.), which was applied to compare concentration of SERT between the test and retest cerebral scans.The average of specific uptake ratio (SUR: target/cerebellum-1) of 123I-ADAM binding to SERT in midbrain was 1.78±0.27, pons was 1.21±0.53, and striatum was 0.79±0.13. The cronbach's α of intra-class correlation coefficient (ICC) was 0.92. Besides, there was also no significant statistical finding in cerebral area using SPM2 analysis. This finding might help us

  11. Macrocyclic polyaminocarboxylates for stable radiometal antibody conjugates for therapy, SPECT and PET imaging

    DOEpatents

    Mease, R.C.; Mausner, L.F.; Srivastava, S.C.

    1997-06-17

    A simple method for the synthesis of 1,4,7, 10-tetraazacyclododecane N,N{prime}N{double_prime},N{prime}{double_prime}-tetraacetic acid and 1,4,8,11-tetraazacyclotetradecane N,N{prime},N{double_prime},N{prime}{double_prime}-tetraacetic acid involves cyanomethylating 1,4,7,10-tetraazacyclododecane or 1,4,8,11-tetraazacyclotetradecane to form a tetranitrile and hydrolyzing the tetranitrile. These macrocyclic compounds are functionalized through one of the carboxylates and then conjugated to various biological molecules including monoclonal antibodies. The resulting conjugated molecules are labeled with radiometals for SPECT and PET imaging and for radiotherapy. 4 figs.

  12. Complementary role of SPECT in the diagnosis of cavernous hemangioma of the liver

    SciTech Connect

    Tumeh, S.S.; English, R.J.; Holman, B.L.

    1985-12-01

    Cavernous hemangiomas are the most common benign tumors of the liver. Although their clinical course is usually uncomplicated, an accurate diagnosis may be important to exclude conditions that need treatment, (or to avoid an unnecessarily risky percutaneous biopsy). Although blood pool scintigraphy using planar gamma camera imaging is a reliable examination for the diagnosis of liver hemangiomas, it may fail to depict small, deeply seated lesions, and hence miss the diagnosis. Two cases are reported in which SPECT demonstrated delayed pooling in small, deep, space-occupying lesions, which were poorly seen on planar images, and therefore made a cavernous hemangioma the most likely diagnosis.

  13. Fast computation of statistical uncertainty for spatiotemporal distributions estimated directly from dynamic cone beam SPECT projections

    SciTech Connect

    Reutter, Bryan W.; Gullberg, Grant T.; Huesman, Ronald H.

    2001-04-09

    The estimation of time-activity curves and kinetic model parameters directly from projection data is potentially useful for clinical dynamic single photon emission computed tomography (SPECT) studies, particularly in those clinics that have only single-detector systems and thus are not able to perform rapid tomographic acquisitions. Because the radiopharmaceutical distribution changes while the SPECT gantry rotates, projections at different angles come from different tracer distributions. A dynamic image sequence reconstructed from the inconsistent projections acquired by a slowly rotating gantry can contain artifacts that lead to biases in kinetic parameters estimated from time-activity curves generated by overlaying regions of interest on the images. If cone beam collimators are used and the focal point of the collimators always remains in a particular transaxial plane, additional artifacts can arise in other planes reconstructed using insufficient projection samples [1]. If the projection samples truncate the patient's body, this can result in additional image artifacts. To overcome these sources of bias in conventional image based dynamic data analysis, we and others have been investigating the estimation of time-activity curves and kinetic model parameters directly from dynamic SPECT projection data by modeling the spatial and temporal distribution of the radiopharmaceutical throughout the projected field of view [2-8]. In our previous work we developed a computationally efficient method for fully four-dimensional (4-D) direct estimation of spatiotemporal distributions from dynamic SPECT projection data [5], which extended Formiconi's least squares algorithm for reconstructing temporally static distributions [9]. In addition, we studied the biases that result from modeling various orders temporal continuity and using various time samplings [5]. the present work, we address computational issues associated with evaluating the statistical uncertainty of

  14. Investigation of the relationship between linear attenuation coefficients and CT Hounsfield units using radionuclides for SPECT.

    PubMed

    Brown, Saxby; Bailey, Dale L; Willowson, Kathy; Baldock, Clive

    2008-09-01

    This study has investigated the relationship between linear attenuation coefficients (mu) and Hounsfield units (HUs) for six materials covering the range of values found clinically. Narrow-beam mu values were measured by performing radionuclide transmission scans using (99m)Tc, (123)I, (131)I, (201)Tl and (111)In. The mu values were compared to published data. The relationships between mu and HU were determined. These relationships can be used to convert computed tomography (CT) images to mu-maps for single photon emission computed tomography (SPECT) attenuation correction. PMID:18662614

  15. Experience with 123I-iomazenil SPECT in acute cerebral infarction.

    PubMed

    Müller, V; Saur, D; Klutmann, S; Weiller, C; Röther, J; Clausen, M

    2002-12-01

    Neuronal cells are susceptible to cerebral ischaemia. As gamma-aminobutyric acid(A) (GABA(A)) receptors are specific for neurones, functional receptor imaging using I-iomazenil (IMZ), a ligand to the GABA benzodiazepine receptor, has been proposed as an imaging modality for the assessment of neuronal integrity. However, there is only limited experience with IMZ in patients with acute cerebral infarction. Therefore, the aim of this study was to evaluate IMZ single photon emission computed tomography (SPECT) in patients with acute cerebral ischaemia. IMZ SPECT was performed in 21 patients with acute cerebral infarction 7-10 days after stroke onset. Eleven patients underwent systemic thrombolysis within 6 h after symptom onset (group 1), whereas 10 patients were treated conservatively (group 2). IMZ (150-200 MBq) was injected intravenously and imaging was performed using a dedicated four-head SPECT camera at 5 min (perfusion) and 90 min (receptor distribution) post-injection, with an acquisition time of 50 min each. Images were analysed by visual inspection. Four patients showed normal IMZ distribution, and 17 patients showed abnormalities of IMZ uptake on both early and late images. In six patients with regional uptake deficits, a crossed cerebellar diaschisis was observed on early images. Cerebellar inhomogeneity of tracer uptake was absent at the time of late images in all six patients. In eight patients, areas of hypoperfusion corresponded exactly to the regions of receptor deficiency (match). In five patients, preserved neuronal integrity was present in hypoperfused areas (mismatch). In four patients, normally or even hyperperfused areas exhibited regional receptor deficiency (inverse mismatch). In conclusion, IMZ SPECT demonstrated differences between regional perfusion and receptor distribution in about one-half of patients 7-10 days after acute cerebral ischaemia. Interesting patterns between the early phase (perfusion) and the late phase (receptor

  16. Regularized reconstruction in quantitative SPECT using CT side information from hybrid imaging

    NASA Astrophysics Data System (ADS)

    Dewaraja, Yuni K.; Koral, Kenneth F.; Fessler, Jeffrey A.

    2010-05-01

    A penalized-likelihood (PL) SPECT reconstruction method using a modified regularizer that accounts for anatomical boundary side information was implemented to achieve accurate estimates of both the total target activity and the activity distribution within targets. In both simulations and experimental I-131 phantom studies, reconstructions from (1) penalized likelihood employing CT-side information-based regularization (PL-CT), (2) penalized likelihood with edge preserving regularization (no CT) and (3) penalized likelihood with conventional spatially invariant quadratic regularization (no CT) were compared with (4) ordered subset expectation maximization (OSEM), which is the iterative algorithm conventionally used in clinics for quantitative SPECT. Evaluations included phantom studies with perfect and imperfect side information and studies with uniform and non-uniform activity distributions in the target. For targets with uniform activity, the PL-CT images and profiles were closest to the 'truth', avoided the edge offshoots evident with OSEM and minimized the blurring across boundaries evident with regularization without CT information. Apart from visual comparison, reconstruction accuracy was evaluated using the bias and standard deviation (STD) of the total target activity estimate and the root mean square error (RMSE) of the activity distribution within the target. PL-CT reconstruction reduced both bias and RMSE compared with regularization without side information. When compared with unregularized OSEM, PL-CT reduced RMSE and STD while bias was comparable. For targets with non-uniform activity, these improvements with PL-CT were observed only when the change in activity was matched by a change in the anatomical image and the corresponding inner boundary was also used to control the regularization. In summary, the present work demonstrates the potential of using CT side information to obtain improved estimates of the activity distribution in targets without

  17. Patient-specific dosimetry based on quantitative SPECT imaging and 3D-DFT convolution

    SciTech Connect

    Akabani, G.; Hawkins, W.G.; Eckblade, M.B.; Leichner, P.K.

    1999-01-01

    The objective of this study was to validate the use of a 3-D discrete Fourier Transform (3D-DFT) convolution method to carry out the dosimetry for I-131 for soft tissues in radioimmunotherapy procedures. To validate this convolution method, mathematical and physical phantoms were used as a basis of comparison with Monte Carlo transport (MCT) calculations which were carried out using the EGS4 system code. The mathematical phantom consisted of a sphere containing uniform and nonuniform activity distributions. The physical phantom consisted of a cylinder containing uniform and nonuniform activity distributions. Quantitative SPECT reconstruction was carried out using the Circular Harmonic Transform (CHT) algorithm.

  18. Pulmonary Ventilation Imaging Based on 4-Dimensional Computed Tomography: Comparison With Pulmonary Function Tests and SPECT Ventilation Images

    SciTech Connect

    Yamamoto, Tokihiro; Kabus, Sven; Lorenz, Cristian; Mittra, Erik; Hong, Julian C.; Chung, Melody; Eclov, Neville; To, Jacqueline; Diehn, Maximilian; Loo, Billy W.; Keall, Paul J.

    2014-10-01

    Purpose: 4-dimensional computed tomography (4D-CT)-based pulmonary ventilation imaging is an emerging functional imaging modality. The purpose of this study was to investigate the physiological significance of 4D-CT ventilation imaging by comparison with pulmonary function test (PFT) measurements and single-photon emission CT (SPECT) ventilation images, which are the clinical references for global and regional lung function, respectively. Methods and Materials: In an institutional review board–approved prospective clinical trial, 4D-CT imaging and PFT and/or SPECT ventilation imaging were performed in thoracic cancer patients. Regional ventilation (V{sub 4DCT}) was calculated by deformable image registration of 4D-CT images and quantitative analysis for regional volume change. V{sub 4DCT} defect parameters were compared with the PFT measurements (forced expiratory volume in 1 second (FEV{sub 1}; % predicted) and FEV{sub 1}/forced vital capacity (FVC; %). V{sub 4DCT} was also compared with SPECT ventilation (V{sub SPECT}) to (1) test whether V{sub 4DCT} in V{sub SPECT} defect regions is significantly lower than in nondefect regions by using the 2-tailed t test; (2) to quantify the spatial overlap between V{sub 4DCT} and V{sub SPECT} defect regions with Dice similarity coefficient (DSC); and (3) to test ventral-to-dorsal gradients by using the 2-tailed t test. Results: Of 21 patients enrolled in the study, 18 patients for whom 4D-CT and either PFT or SPECT were acquired were included in the analysis. V{sub 4DCT} defect parameters were found to have significant, moderate correlations with PFT measurements. For example, V{sub 4DCT}{sup HU} defect volume increased significantly with decreasing FEV{sub 1}/FVC (R=−0.65, P<.01). V{sub 4DCT} in V{sub SPECT} defect regions was significantly lower than in nondefect regions (mean V{sub 4DCT}{sup HU} 0.049 vs 0.076, P<.01). The average DSCs for the spatial overlap with SPECT ventilation defect regions were only moderate (V

  19. Single-photon emission computed tomography (SPECT): Applications and potential

    SciTech Connect

    Holman, B.L.; Tumeh, S.S. )

    1990-01-26

    Single-photon emission computed tomography has received increasing attention as radiopharmaceuticals that reflect perfusion, metabolism, and receptor and cellular function have become widely available. Perfusion single-photon emission computed tomography of the brain provides functional information useful for the diagnosis and management of stroke, dementia, and epilepsy. Single-photon emission computed tomography has been applied to myocardial, skeletal, hepatic, and tumor scintigraphy, resulting in increased diagnostic accuracy over planar imaging because background activity and overlapping tissues interfere far less with activity from the target structure when tomographic techniques are used. Single-photon emission computed tomography is substantially less expensive and far more accessible than positron emission tomography and will become an increasingly attractive alternative for transferring the positron emission tomography technology to routine clinical use.

  20. A methodology for selecting the beam arrangement to reduce the intensity-modulated radiation therapy (IMRT) dose to the SPECT-defined functioning lung

    NASA Astrophysics Data System (ADS)

    McGuire, S. M.; Marks, L. B.; Yin, F. F.; Das, S. K.

    2010-01-01

    Macroaggregated albumin single-photon emission computed tomography (MAA-SPECT) provides a map of the spatial distribution of lung perfusion. Our previous work developed a methodology to use SPECT guidance to reduce the dose to the functional lung in IMRT planning. This study aims to investigate the role of beam arrangement on both low and high doses in the functional lung. In our previous work, nine-beam IMRT plans were generated with and without SPECT guidance and compared for five patients. For the current study, the dose-function histogram (DFH) contribution for each of the nine beams for each patient was calculated. Four beams were chosen based on orientation and DFH contributions to create a SPECT-guided plan that spared the functional lung and maintained target coverage. Four-beam SPECT-guided IMRT plans reduced the F20 and F30 values by (16.5 ± 6.8)% and (6.1 ± 9.2)%, respectively, when compared to nine-beam conventional IMRT plans. Moreover, the SPECT-4F Plan reduces F5 and F13 for all patients by (11.0 ± 8.2)% and (6.1 ± 3.6)%, respectively, compared to the SPECT Plan. Using fewer beams in IMRT planning may reduce the amount of functional lung that receives 5 and 13 Gy, a factor that has recently been associated with radiation pneumonitis.

  1. A methodology for selecting the beam arrangement to reduce the intensity-modulated radiation therapy (IMRT) dose to the SPECT-defined functioning lung.

    PubMed

    McGuire, S M; Marks, L B; Yin, F F; Das, S K

    2010-01-21

    Macroaggregated albumin single-photon emission computed tomography (MAA-SPECT) provides a map of the spatial distribution of lung perfusion. Our previous work developed a methodology to use SPECT guidance to reduce the dose to the functional lung in IMRT planning. This study aims to investigate the role of beam arrangement on both low and high doses in the functional lung. In our previous work, nine-beam IMRT plans were generated with and without SPECT guidance and compared for five patients. For the current study, the dose-function histogram (DFH) contribution for each of the nine beams for each patient was calculated. Four beams were chosen based on orientation and DFH contributions to create a SPECT-guided plan that spared the functional lung and maintained target coverage. Four-beam SPECT-guided IMRT plans reduced the F(20) and F(30) values by (16.5 +/- 6.8)% and (6.1 +/- 9.2)%, respectively, when compared to nine-beam conventional IMRT plans. Moreover, the SPECT-4F Plan reduces F(5) and F(13) for all patients by (11.0 +/- 8.2)% and (6.1 +/- 3.6)%, respectively, compared to the SPECT Plan. Using fewer beams in IMRT planning may reduce the amount of functional lung that receives 5 and 13 Gy, a factor that has recently been associated with radiation pneumonitis. PMID:20019404

  2. [Ischemic heart disease (myocardial perfusion and viability): techniques and results].

    PubMed

    Croisille, P

    2004-10-01

    Over the last two decades, the understanding, diagnosis and treatment of patients with suspected or known coronary artery disease have made tremendous progress, in particular with the help of the development of non-invasive methodologies for assessing myocardial perfusion and viability. Clinically, nuclear medicine techniques (particularly SPECT imaging) have predominated. With the recent technical developments allowing for a combined assessment of perfusion and irreversible damage with late enhancement imaging, MRI will now play a major role in the assessment of ischemic heart disease. PMID:15507837

  3. Fully 4D motion-compensated reconstruction of cardiac SPECT images

    NASA Astrophysics Data System (ADS)

    Gravier, Erwan; Yang, Yongyi; King, Michael A.; Jin, Mingwu

    2006-09-01

    In this paper, we investigate the benefits of a spatiotemporal approach for reconstruction of image sequences. In the proposed approach, we introduce a temporal prior in the form of motion compensation to account for the statistical correlations among the frames in a sequence, and reconstruct all the frames collectively as a single function of space and time. The reconstruction algorithm is derived based on the maximum a posteriori estimate, for which the one-step late expectation-maximization algorithm is used. We demonstrated the method in our experiments using simulated single photon emission computed tomography (SPECT) cardiac perfusion images. The four-dimensional (4D) gated mathematical cardiac-torso phantom was used for simulation of gated SPECT perfusion imaging with Tc-99m-sestamibi. In addition to bias-variance analysis and time activity curves, we also used a channelized Hotelling observer to evaluate the detectability of perfusion defects in the reconstructed images. Our experimental results demonstrated that the incorporation of temporal regularization into image reconstruction could significantly improve the accuracy of cardiac images without causing any significant cross-frame blurring that may arise from the cardiac motion. This could lead to not only improved detection of perfusion defects, but also improved reconstruction of the heart wall which is important for functional assessment of the myocardium. This work was supported in part by the National Institutes of Health under grant no HL65425.

  4. First Experiences with Navigated Radio-Guided Surgery Using Freehand SPECT

    PubMed Central

    Rieger, A.; Saeckl, J.; Belloni, B.; Hein, R.; Okur, A.; Scheidhauer, K.; Wendler, T.; Traub, J.; Friess, H.; Martignoni, M.E.

    2011-01-01

    Background Sentinel lymph node biopsy (SLNB) in melanoma using one-dimensional gamma probes is a standard of care worldwide. Reports on the performance are claimed by most groups to successfully detect the SLNs during the surgical procedure in almost 100% of the patients. In clinical practice, however, several issues remain which are usually not addressed: the difficulty of intraoperative detection of deeply located nodes, SLN detection in obese patients or in the groin and the impossibility to make a scan of the entire wound after SLN resection to avoid false negative testing for eventually remaining SLNs. Materials and Methods The concept behind freehand SPECT is to combine a gamma probe as used for conventional radio-guided surgery with a tracking system as used in neurosurgical navigation. From this combination and a proper algorithm framework the 3D reconstruction of radioactivity distributions and displaying these intraoperatively is possible. Conclusion In summary, the feasibility of freehand SPECT could be shown and provides an image-guided SLNB and a truly minimally invasive and optimized surgical procedure. PMID:21941492

  5. A filtered backprojection algorithm for axial head motion correction in fan-beam SPECT.

    PubMed

    Li, J; Jaszczak, R J; Coleman, R E

    1995-12-01

    In this study we present an approximate, but practical, three-dimensional filtered backprojection (FBP) reconstruction algorithm in fan-beam SPECT to correct for axial motion (both translation and rotation). A one-dimensional filter kernel was applied to the projections. It is assumed that the object is rigid and that its axial motion can be characterized by three components: one-dimensional translation and yaw and pitch rotations. It is further assumed that the motions that have occurred during the SPECT acquisition have been determined separately. The determined angular-view-dependent translation/rotation parameters were incorporated into the proposed FBP algorithm to correct for multiple axial head motions. The proposed axial head motion correction algorithm was evaluated using simulated three-dimensional Hoffman brain phantom data. Projections both with axial translation and with axial rotation, and with their combinations were generated. Images of a Hoffman brain phantom reconstructed using the proposed FBP algorithm and the conventional FBP algorithm were compared. Artefacts were observed in images without motion correction, but the artefacts were greatly reduced using the proposed reconstruction algorithm.

  6. Gold Nanoparticles Doped with (199) Au Atoms and Their Use for Targeted Cancer Imaging by SPECT.

    PubMed

    Zhao, Yongfeng; Pang, Bo; Luehmann, Hannah; Detering, Lisa; Yang, Xuan; Sultan, Deborah; Harpstrite, Scott; Sharma, Vijay; Cutler, Cathy S; Xia, Younan; Liu, Yongjian

    2016-04-20

    Gold nanoparticles have been labeled with various radionuclides and extensively explored for single photon emission computed tomography (SPECT) in the context of cancer diagnosis. The stability of most radiolabels, however, still needs to be improved for accurate detection of cancer biomarkers and thereby monitoring of tumor progression and metastasis. Here, the first synthesis of Au nanoparticles doped with (199)Au atoms for targeted SPECT tumor imaging in a mouse triple negative breast cancer (TNBC) model is reported. By directly incorporating (199)Au atoms into the crystal lattice of each Au nanoparticle, the stability of the radiolabel can be ensured. The synthetic procedure also allows for a precise control over both the radiochemistry and particle size. When conjugated with D-Ala1-peptide T-amide, the Au nanoparticles doped with (199)Au atoms can serve as a C-C chemokine receptor 5 (CCR5)-targeted nanoprobe for the sensitive and specific detection of both TNBC and its metastasis in a mouse tumor model.

  7. The nurse's role in delivery of radioisotope for ictal SPECT scan.

    PubMed

    Huntington, N A

    1999-08-01

    The Medical College of Georgia Hospital and Clinics (MCG) was one of the first centers in the United States (US) to institute a video electroencephalography (EEG) epilepsy monitoring unit and epilepsy surgery program. In order to surgically remove the area in the brain giving rise to seizures, the epileptogenic zone must be identified and localized. One of the newer methods used to identify the epileptogenic seizure focus is the ictal Single Photon Emission Computed Tomography (SPECT) scan, which MCG began performing in 1993. The nurses staffing the six bed Epilepsy Monitoring Unit (EMU) are trained by the Nuclear Radiology Department and Radiation Safety Officer to bandle the radioisotope during mixing, calibration and injection. The bedside nursing protocol developed assures patient and staff radiation safety and efficacious injection. Over 300 patients have been injected by nurses with a high degree of safety to patients and staff. This has resulted in positive scans that aid diagnosis. The success of the ictal SPECT protocol can be attributed to the active collaboration of our multidisciplinary team.

  8. Frequency of late reversibility in stress-redistribution thallium-201 SPECT using an early reinjection protocol

    SciTech Connect

    Kiat, H.; Friedman, J.D.; Wang, F.P.; Van Train, K.F.; Maddahi, J.; Takemoto, K.; Berman, D.S. )

    1991-09-01

    To assess the efficacy of an early thallium-201 reinjection protocol for reducing the need for late redistribution imaging, the frequency of thallium-201 late reversibility was prospectively assessed in 62 patients who had stress-redistribution thallium-201 studies by single-photon emission computerized tomography (SPECT), and who received 1 mCi of thallium-201 reinjection immediately following stress tomographic acquisition. These patients also demonstrated greater than or equal to 2 segments with nonreversible defects at 4-hour imaging and underwent late (18-to 72-hour) redistribution imaging. When the criterion of late reversibility was defined as greater than or equal to 1 segment with a 4-hour nonreversible defect demonstrating late reversibility, late reversibility was present in 36 (58%) of the 62 patients and in 88 (24%) of 368 SPECT segments. When the criterion of greater than or equal to 2 segments was used, late reversibility was found in 21 (34%) of the 62 patients and in 73 (20%) of the 368 segments. Of the 21 patients who had greater than or equal to 2 late reversible segments, 12 (57%) exhibited late reversibility in greater than or equal to 3 segments. The frequency of detected reversible defects increased from 32% by 4-hour imaging to 48% by combined 4-hour and late imaging (p less than 0.0001). The patients who demonstrated late reversibility could not be distinguished from those who had only late nonreversible defects by analysis of the clinical, exercise, and electrocardiographic (ECG) variables.

  9. Structural (CT) and functional imaging (PET/SPECT) for the investigation of dolphin bioacoustics

    NASA Astrophysics Data System (ADS)

    Houser, Dorian S.; Finneran, James J.; Mattrey, Robert; Hoh, Carl; Ridgway, Sam

    2003-10-01

    A combination of imaging modalities was used to address physiological and anatomical questions relevant to dolphin bioacoustics. Three dolphins (Tursiops truncatus) were scanned with CT to investigate in vivo dolphin cranial anatomy. One dolphin underwent SPECT and PET scanning to investigate blood flow and metabolic activity of the cranial tissues. Air spaces were mostly contiguous and covered the periotic bone and auditory bulla dorsally and medially. Cranial air was compartmentalized by the nasal plug and constriction of the palatopharyngeus muscle. Blood flow, determined from SPECT imaging of 99Tc-bicisate distribution, was greatest in the brain, melon, and posterior fats of the lower jaw. Metabolic activity of tissues, assessed by monitoring the uptake of 18F-deoxyglucose via PET, indicated that melon and jaw fats were metabolically inert compared to the brain. Nasal cavity and sinus air volume that is reduced during diving may be replenished with lung air via the palatopharyngeus and Eustachian tube. Air covering the bulla may protect the ears from outgoing echolocation pulses and contribute to spectral and time of arrival cues. Blood flow to the melon and lower jaw fats may serve to either regulate the temperature of acoustic lipids or act as a site of counter-current heat exchange.

  10. Evaluation of a low-dose/slow-rotating SPECT-CT system

    NASA Astrophysics Data System (ADS)

    Hamann, M.; Aldridge, M.; Dickson, J.; Endozo, R.; Lozhkin, K.; Hutton, B. F.

    2008-05-01

    The 4-slice CT that forms part of the GE Infinia Hawkeye-4 SPECT-CT scanner (Hawkeye) is evaluated against the diagnostic 16-slice CT that is incorporated in the GE Discovery ST PET-CT system (DST). The x-ray tube of the slow-rotating Hawkeye system (23 s/rotation) operates at approximately a third of the dose of diagnostic systems as used for conventional diagnostic imaging. Image reconstruction is optimized for low noise. High-contrast spatial resolution significantly falls behind diagnostic figures: the average of MTF50 and MTF10 (resolution where the MTF has fallen to 50% and 10%) is 2.8 ± 0.1 cm-1 for Hawkeye and 5.3 ± 0.1 cm-1 for the DST (standard reconstruction filters). Resolution in the direction of the couch movement (z coordinate) is governed by the fixed Hawkeye slice width of 5 mm. Reconstruction accuracy is found to be increased by reducing the default z increment from 4.4 mm to 2.2 mm. Low-contrast object detectability is superior compared with diagnostic systems operating in the Hawkeye dose range. In the diagnostic dose regime, however, small low-contrast details remain visible in DST that are not detectable with Hawkeye. Although not of diagnostic quality, the low-dose Hawkeye provides appropriate data for SPECT attenuation correction and anatomical localization capability. For more information on this article, see medicalphysicsweb.org

  11. The neutron decay retardation spectrometer aSPECT: Electromagnetic design and systematic effects

    NASA Astrophysics Data System (ADS)

    Glück, F.; Baeßler, S.; Byrne, J.; van der Grinten, M. G. D.; Hartmann, F. J.; Heil, W.; Konorov, I.; Petzoldt, G.; Sobolev, Yu.; Zimmer, O.

    2005-01-01

    The apparatus described here, aSPECT, will be used for a measurement of the neutrino-electron angular correlation coefficient a in the decay of free neutrons. The idea of the aSPECT spectrometer is to measure the integrated proton energy spectrum very accurately using an energy filter by electrostatic retardation and magnetic adiabatic collimation. The main ideas of the spectrometer are presented, followed by an explanation of the adiabatic transmission function. Details of the superconducting coil and of the electrode system are given, as well as a discussion of the most important systematic effects: magnetic field and electrostatic potential inhomogeneities, deviation from adiabatic motion, scattering in the residual gas, background, Doppler effect, edge effect, and detector efficiency. Using this spectrometer, the parameter a is planned to be measured with an absolute experimental uncertainty of δ a ≈ 3 . 10-4, from which the axial vector to vector coupling constant ratio λ can be determined with an accuracy of δλ ≈ 0.001.

  12. Amplitude-based data selection for optimal retrospective reconstruction in micro-SPECT

    NASA Astrophysics Data System (ADS)

    Breuilly, M.; Malandain, G.; Guglielmi, J.; Marsault, R.; Pourcher, T.; Franken, P. R.; Darcourt, J.

    2013-04-01

    Respiratory motion can blur the tomographic reconstruction of positron emission tomography or single-photon emission computed tomography (SPECT) images, which subsequently impair quantitative measurements, e.g. in the upper abdomen area. Respiratory signal phase-based gated reconstruction addresses this problem, but deteriorates the signal-to-noise ratio (SNR) and other intensity-based quality measures. This paper proposes a 3D reconstruction method dedicated to micro-SPECT imaging of mice. From a 4D acquisition, the phase images exhibiting motion are identified and the associated list-mode data are discarded, which enables the reconstruction of a 3D image without respiratory artefacts. The proposed method allows a motion-free reconstruction exhibiting both satisfactory count statistics and accuracy of measures. With respect to standard 3D reconstruction (non-gated 3D reconstruction) without breathing motion correction, an increase of 14.6% of the mean standardized uptake value has been observed, while, with respect to a gated 4D reconstruction, up to 60% less noise and an increase of up to 124% of the SNR have been demonstrated.

  13. A SPECT system simulator built on the SolidWorksTM 3D-Design package

    PubMed Central

    Li, Xin; Furenlid, Lars R.

    2015-01-01

    We have developed a GPU-accelerated SPECT system simulator that integrates into instrument-design workflow [1]. This simulator includes a gamma-ray tracing module that can rapidly propagate gamma-ray photons through arbitrary apertures modeled by SolidWorksTM-created stereolithography (.STL) representations with a full complement of physics cross sections [2, 3]. This software also contains a scintillation detector simulation module that can model a scintillation detector with arbitrary scintillation crystal shape and light-sensor arrangement. The gamma-ray tracing module enables us to efficiently model aperture and detector crystals in SolidWorksTM and save them as STL file format, then load the STL-format model into this module to generate list-mode results of interacted gamma-ray photon information (interaction positions and energies) inside the detector crystals. The Monte-Carlo scintillation detector simulation module enables us to simulate how scintillation photons get reflected, refracted and absorbed inside a scintillation detector, which contributes to more accurate simulation of a SPECT system. PMID:26190885

  14. Alzheimer disease: Quantitative analysis of I-123-iodoamphetamine SPECT brain imaging

    SciTech Connect

    Hellman, R.S.; Tikofsky, R.S.; Collier, B.D.; Hoffmann, R.G.; Palmer, D.W.; Glatt, S.L.; Antuono, P.G.; Isitman, A.T.; Papke, R.A.

    1989-07-01

    To enable a more quantitative diagnosis of senile dementia of the Alzheimer type (SDAT), the authors developed and tested a semiautomated method to define regions of interest (ROIs) to be used in quantitating results from single photon emission computed tomography (SPECT) of regional cerebral blood flow performed with N-isopropyl iodine-123-iodoamphetamine. SPECT/IMP imaging was performed in ten patients with probable SDAT and seven healthy subjects. Multiple ROIs were manually and semiautomatically generated, and uptake was quantitated for each ROI. Mean cortical activity was estimated as the average of the mean activity in 24 semiautomatically generated ROIs; mean cerebellar activity was determined from the mean activity in separate ROIs. A ratio of parietal to cerebellar activity less than 0.60 and a ratio of parietal to mean cortical activity less than 0.90 allowed correct categorization of nine of ten and eight of ten patients, respectively, with SDAT and all control subjects. The degree of diminished mental status observed in patients with SDAT correlated with both global and regional changes in IMP uptake.

  15. GATE simulation of a LYSO-based SPECT imager: Validation and detector optimization

    NASA Astrophysics Data System (ADS)

    Li, Suying; Zhang, Qiushi; Xie, Zhaoheng; Liu, Qi; Xu, Baixuan; Yang, Kun; Li, Changhui; Ren, Qiushi

    2015-02-01

    This paper presents a small animal SPECT system that is based on cerium doped lutetium-yttrium oxyorthosilicate (LYSO) scintillation crystal, position sensitive photomultiplier tubes (PSPMTs) and parallel hole collimator. Spatial resolution test and animal experiment were performed to demonstrate the imaging performance of the detector. Preliminary results indicated a spatial resolution of 2.5 mm at FWHM that cannot meet our design requirement. Therefore, we simulated this gamma camera using GATE (GEANT 4 Application for Tomographic Emission) aiming to make detector spatial resolution less than 2 mm. First, the GATE simulation process was validated through comparison between simulated and experimental data. This also indicates the accuracy and effectiveness of GATE simulation for LYSO-based gamma camera. Then the different detector sampling methods (crystal size with 1.5, and 1 mm) and collimator design (collimator height with 30, 34.8, 38, and 43 mm) were studied to figure out an optimized parameter set. Detector sensitivity changes were also focused on with different parameters set that generated different spatial resolution results. Tradeoff curves of spatial resolution and sensitivity were plotted to determine the optimal collimator height with different sampling methods. Simulation results show that scintillation crystal size of 1 mm and collimator height of 38 mm, which can generate a spatial resolution of ~1.8 mm and sensitivity of ~0.065 cps/kBq, can be an ideal configuration for our SPECT imager design.

  16. A case of Kleine-Levin syndrome examined with SPECT and neuropsychological testing.

    PubMed

    Landtblom, A-M; Dige, N; Schwerdt, K; Säfström, P; Granérus, G

    2002-04-01

    A case of Kleine-Levin syndrome with typical periodic hypersomnia and bulimia was diagnosed. On examination with single photo emission tomography (SPECT) (CERETEC) during a relapse period and 2 weeks later there was marked cortical hypoperfusion of the frontal and temporal lobes, especially on the left side as well as in the right parietal lobe. Neuropsychological testing performed 1 week after a relapse showed a reduction in encoding to memory function of verbal learning indicating neocortical damage of the left fronto-temporal region. A follow-up 2 months later after the patient had spontaneously recovered showed only a slight left fronto-temporal disturbance. CT and MRI of the brain were normal although the MRI showed a large and asymmetric mamillary body. Neuropsychological testing 6 years after recovery showed pronounced reduction in short-time verbal and visual memory. Seven years after recovery SPECT demonstrated a normalized frontal perfusion but still a slight hypoperfusion in the left temporal lobe. Our results correlate to autopsy findings in two cases described previously.

  17. Multi-pinhole SPECT calibration: influence of data noise and systematic orbit deviations.

    PubMed

    Zhou, Lin; Vunckx, Kathleen; Nuyts, Johan

    2011-10-01

    The geometry of a single pinhole SPECT system with circular orbit can be uniquely determined from a measurement of three point sources, provided that at least two inter-point distances are known. In contrast, it has been shown mathematically that, for a multi-pinhole SPECT system with circular orbit, only two point sources are needed, and the knowledge of the distance between them is not required. In this paper, we report that this conclusion only holds if the motion of the camera is perfectly circular. In reality, the detector heads systematically slightly deviate from the circular orbit, which may introduce non-negligible bias in the estimated parameters and degrade the reconstructed image. An analytical linear model was extended to estimate the influence of both data noise and systematic deviations on the accuracy of the calibration and on the image quality of the reconstruction. It turns out that applying the knowledge of the distances greatly reduces the reconstruction error, especially in the presence of systematic deviations. In addition, we propose that instead of using the information about the distances between the point sources, it is more straightforward to use the knowledge about the distances between the pinhole apertures during multi-pinhole calibration. The two distance-fixing approaches yield similar reconstruction accuracy. Our theoretical results are supported by reconstruction images of a Jaszczak-type phantom scan.

  18. SPECT assay of radiolabeled monoclonal antibodies. Progress report, September 1, 1992--August 24, 1993

    SciTech Connect

    Jaszczak, R.J.

    1993-08-20

    The overall goal of this project is to improve the effectiveness of single photon emission computed tomography (SPECT) to image and quantify radiolabeled monoclonal antibodies. During the past year, we have made significant progress toward this goal, and this report summarizes that work. Our efforts have been mainly directed along three fronts. First, we have developed and tested new reconstruction methods including three-dimensional iterative algorithms that model non-uniform attenuation and distance-dependent detector response. Both fan beam and parallel beam collimator geometries have been modeled and novel ways of improving the efficiency of the computationally intensive methods have been introduced. Second, an ultra-high resolution, small field-of-view pinhole collimator has been constructed and evaluated. Reconstructed spatial resolution of 1 to 3 mm (FWHM) has been achieved in phantom scans with a useful field-of-view of 9 to 10 cm. Finally, we have investigated the ability of SPECT to image and quantify astatine-211 distributions. Reconstructed images of phantom data demonstrated quantitative accuracy to within 10% with proper attenuation and scatter compensation.

  19. A SPECT system simulator built on the SolidWorksTM 3D design package

    NASA Astrophysics Data System (ADS)

    Li, Xin; Furenlid, Lars R.

    2014-09-01

    We have developed a GPU-accelerated SPECT system simulator that integrates into instrument-design work flow [1]. This simulator includes a gamma-ray tracing module that can rapidly propagate gamma-ray photons through arbitrary apertures modeled by SolidWorksTM-created stereolithography (.STL) representations with a full com- plement of physics cross sections [2, 3]. This software also contains a scintillation detector simulation module that can model a scintillation detector with arbitrary scintillation crystal shape and light-sensor arrangement. The gamma-ray tracing module enables us to efficiently model aperture and detector crystals in SolidWorksTM and save them as STL file format, then load the STL-format model into this module to generate list-mode results of interacted gamma-ray photon information (interaction positions and energies) inside the detector crystals. The Monte-Carlo scintillation detector simulation module enables us to simulate how scintillation photons get reflected, refracted and absorbed inside a scintillation detector, which contributes to more accurate simulation of a SPECT system.

  20. Collimator performance evaluation for In-111 SPECT using a detection/localization task

    NASA Astrophysics Data System (ADS)

    Lu, Yihuan; Chen, Lin; Gindi, Gene

    2014-02-01

    In SPECT, the collimator is a crucial element in controlling image quality. We take a task performance approach to collimator performance evaluation in which an ideal observer is applied to the raw camera data without regard to the subsequent reconstruction stage. The clinical context of our collimator study is one of searching for and detecting neuroendocrine tumor metastases in the liver as seen in In-111 Octreotide SPECT. Our task involves detection and localization of a signal and thus differs from the conventionally used detection-only task. The scalar task performance metric is ALROC, the area under the localization receiver operating characteristic curve. Since In-111 emits photons at both 171 and 245 keV, the higher energy emissions can contribute significant septal scatter and penetration. Our collimator evaluations address a question previously considered by Mähler et al (2012 IEEE Trans. Nucl. Sci. 59 47-53) who used a different methodology: does allowing a limited amount of septal scatter and penetration yield improved task performance? We used simulation methods to evaluate five parallel-hole collimators. The collimators had roughly equal geometric sensitivity and resolution but a range of contributions from septal effects leading to variations in total sensitivity and resolution. We found that the best performance was obtained with a collimator that allowed a moderate amount of septal scatter and penetration.

  1. SPECT Perfusion Imaging Demonstrates Improvement of Traumatic Brain Injury With Transcranial Near-infrared Laser Phototherapy.

    PubMed

    Henderson, Theodore A; Morries, Larry D

    2015-01-01

    Traumatic brain injury (TBI) is a growing health concern affecting civilians and military personnel. Near-infrared (NIR) light has shown benefits in animal models and human trials for stroke and in animal models for TBI. Diodes emitting low-level NIR often have lacked therapeutic efficacy, perhaps failing to deliver sufficient radiant energy to the necessary depth. In this case report, a patient with moderate TBI documented in anatomical magnetic resonance imaging (MRI) and perfusion single-photon emission computed tomography (SPECT) received 20 NIR treatments in the course of 2 mo using a high-power NIR laser. Symptoms were monitored by clinical examination and a novel patient diary system specifically designed for this patient population. Clinical application of these levels of infrared energy for this patient with TBI yielded highly favorable outcomes with decreased depression, anxiety, headache, and insomnia, whereas cognition and quality of life improved. Neurological function appeared to improve based on changes in the SPECT by quantitative analysis. NIR in the power range of 10-15 W at 810 and 980 nm can safely and effectively treat chronic symptoms of TBI. PMID:26535475

  2. SUV measurement of normal vertebrae using SPECT/CT with Tc-99m methylene diphosphonate