Swayze, G.A.; Clark, R.N.; Goetz, A.F.H.; Chrien, T.H.; Gorelick, N.S.
2003-01-01
Estimates of spectrometer band pass, sampling interval, and signal-to-noise ratio required for identification of pure minerals and plants were derived using reflectance spectra convolved to AVIRIS, HYDICE, MIVIS, VIMS, and other imaging spectrometers. For each spectral simulation, various levels of random noise were added to the reflectance spectra after convolution, and then each was analyzed with the Tetracorder spectra identification algorithm [Clark et al., 2003]. The outcome of each identification attempt was tabulated to provide an estimate of the signal-to-noise ratio at which a given percentage of the noisy spectra were identified correctly. Results show that spectral identification is most sensitive to the signal-to-noise ratio at narrow sampling interval values but is more sensitive to the sampling interval itself at broad sampling interval values because of spectral aliasing, a condition when absorption features of different materials can resemble one another. The band pass is less critical to spectral identification than the sampling interval or signal-to-noise ratio because broadening the band pass does not induce spectral aliasing. These conclusions are empirically corroborated by analysis of mineral maps of AVIRIS data collected at Cuprite, Nevada, between 1990 and 1995, a period during which the sensor signal-to-noise ratio increased up to sixfold. There are values of spectrometer sampling and band pass beyond which spectral identification of materials will require an abrupt increase in sensor signal-to-noise ratio due to the effects of spectral aliasing. Factors that control this threshold are the uniqueness of a material's diagnostic absorptions in terms of shape and wavelength isolation, and the spectral diversity of the materials found in nature and in the spectral library used for comparison. Array spectrometers provide the best data for identification when they critically sample spectra. The sampling interval should not be broadened to increase the signal-to-noise ratio in a photon-noise-limited system when high levels of accuracy are desired. It is possible, using this simulation method, to select optimum combinations of band-pass, sampling interval, and signal-to-noise ratio values for a particular application that maximize identification accuracy and minimize the volume of imaging data.
Research on the principle and experimentation of optical compressive spectral imaging
NASA Astrophysics Data System (ADS)
Chen, Yuheng; Chen, Xinhua; Zhou, Jiankang; Ji, Yiqun; Shen, Weimin
2013-12-01
The optical compressive spectral imaging method is a novel spectral imaging technique that draws in the inspiration of compressed sensing, which takes on the advantages such as reducing acquisition data amount, realizing snapshot imaging, increasing signal to noise ratio and so on. Considering the influence of the sampling quality on the ultimate imaging quality, researchers match the sampling interval with the modulation interval in former reported imaging system, while the depressed sampling rate leads to the loss on the original spectral resolution. To overcome that technical defect, the demand for the matching between the sampling interval and the modulation interval is disposed of and the spectral channel number of the designed experimental device increases more than threefold comparing to that of the previous method. Imaging experiment is carried out by use of the experiment installation and the spectral data cube of the shooting target is reconstructed with the acquired compressed image by use of the two-step iterative shrinkage/thresholding algorithms. The experimental result indicates that the spectral channel number increases effectively and the reconstructed data stays high-fidelity. The images and spectral curves are able to accurately reflect the spatial and spectral character of the target.
NASA Astrophysics Data System (ADS)
Yasui, Takeshi
2017-08-01
Optical frequency combs are innovative tools for broadband spectroscopy because a series of comb modes can serve as frequency markers that are traceable to a microwave frequency standard. However, a mode distribution that is too discrete limits the spectral sampling interval to the mode frequency spacing even though individual mode linewidth is sufficiently narrow. Here, using a combination of a spectral interleaving and dual-comb spectroscopy in the terahertz (THz) region, we achieved a spectral sampling interval equal to the mode linewidth rather than the mode spacing. The spectrally interleaved THz comb was realized by sweeping the laser repetition frequency and interleaving additional frequency marks. In low-pressure gas spectroscopy, we achieved an improved spectral sampling density of 2.5 MHz and enhanced spectral accuracy of 8.39 × 10-7 in the THz region. The proposed method is a powerful tool for simultaneously achieving high resolution, high accuracy, and broad spectral coverage in THz spectroscopy.
Spectrally interleaved, comb-mode-resolved spectroscopy using swept dual terahertz combs
Hsieh, Yi-Da; Iyonaga, Yuki; Sakaguchi, Yoshiyuki; Yokoyama, Shuko; Inaba, Hajime; Minoshima, Kaoru; Hindle, Francis; Araki, Tsutomu; Yasui, Takeshi
2014-01-01
Optical frequency combs are innovative tools for broadband spectroscopy because a series of comb modes can serve as frequency markers that are traceable to a microwave frequency standard. However, a mode distribution that is too discrete limits the spectral sampling interval to the mode frequency spacing even though individual mode linewidth is sufficiently narrow. Here, using a combination of a spectral interleaving and dual-comb spectroscopy in the terahertz (THz) region, we achieved a spectral sampling interval equal to the mode linewidth rather than the mode spacing. The spectrally interleaved THz comb was realized by sweeping the laser repetition frequency and interleaving additional frequency marks. In low-pressure gas spectroscopy, we achieved an improved spectral sampling density of 2.5 MHz and enhanced spectral accuracy of 8.39 × 10−7 in the THz region. The proposed method is a powerful tool for simultaneously achieving high resolution, high accuracy, and broad spectral coverage in THz spectroscopy. PMID:24448604
Future VIIRS enhancements for the integrated polar-orbiting environmental satellite system
NASA Astrophysics Data System (ADS)
Puschell, Jeffery J.; Silny, John; Cook, Lacy; Kim, Eugene
2010-08-01
The Visible/Infrared Imager Radiometer Suite (VIIRS) is the next-generation imaging spectroradiometer for the future operational polar-orbiting environmental satellite system. A successful Flight Unit 1 has been delivered and integrated onto the NPP spacecraft. The flexible VIIRS architecture can be adapted and enhanced to respond to a wide range of requirements and to incorporate new technology as it becomes available. This paper reports on recent design studies to evaluate building a MW-VLWIR dispersive hyperspectral module with active cooling into the existing VIIRS architecture. Performance of a two-grating VIIRS hyperspectral module was studied across a broad trade space defined primarily by spatial sampling, spectral range, spectral sampling interval, along-track field of view and integration time. The hyperspectral module studied here provides contiguous coverage across 3.9 - 15.5 μm with a spectral sampling interval of 10 nm or better, thereby extending VIIRS spectral range to the shortwave side of the 15.5 μm CO2 band and encompassing the 6.7 μm H2O band. Spatial sampling occurs at VIIRS I-band (~0.4 km at nadir) spatial resolution with aggregation to M-band (~0.8 km) and larger pixel sizes to improve sensitivity. Radiometric sensitivity (NEdT) at a spatial resolution of ~4 km is ~0.1 K or better for a 250 K scene across a wavelength range of 4.5 μm to 15.5 μm. The large number of high spectral and spatial resolution FOVs in this instrument improves chances for retrievals of information on the physical state and composition of the atmosphere all the way to the surface in cloudy regions relative to current systems. Spectral aggregation of spatial resolution measurements to MODIS and VIIRS multispectral bands would continue legacy measurements with better sensitivity in nearly all bands. Additional work is needed to optimize spatial sampling, spectral range and spectral sampling approaches for the hyperspectral module and to further refine this powerful imager concept.
Preliminary Observations of Noise Spectra at the SRO and ASRO Stations
Peterson, Jon
1980-01-01
Introduction The seismic noise spectra presented in this report were derived from SRO and ASRO station data for the purpose of evaluating the performance of the seismic instruments. They are also useful for constructing a spectral estimate of earth noise at a quiet site based on noise samples obtained from a network of globally distributed sites. It is hoped that the spectra will be usefull for other purposes as well. The term 'noise' is used here to describe the ambient signals recorded during a quiet period when earthquake signals have not been detected by visual inspectino of the analog seismogram. The total recorded noise is the sum of instrumental noise, environmental noise (such as effects of temperature, pressure, wind), earth background noise from both natural and cultural sources, and very possibly low-level signals from earthquakes that cannot be visually identified. It is not possible to separate and quantify the signals generated by these independent noise sources using a single sample of station data, although instrumental problems may be indicated by gross changes of noise levels, if the changes are not in the microseismic bands. Since seismic data at the SRO and ASRO stations are recorded in a digital format, spectral computations can be automated so that station noise levels can be monitored as part of data-review procedures. The noise spectra presented in this study are intended to serve as an initial baseline against which relative changes in noise levels can be measured. Total noise power was computed separately for the short- and long-period bands, which are recorded separately at the stations. Power spectral densities were derived by averaging the spectral estimates of a number of contiguous dat segments. The mean value and slope were removed from each segment, cosine-tapered windows were applied, and the estimates were obtained using a fast Fourier transform. In the short-period analyses 16 segments were used, each segment being 1024 samples in length. Because the sampling interval is .05 seconds, the total record length is nearly 13.7 minutes. Normally, the short-period SRO and ASRO data are recorded in an event-only mode. However, several days of continuous short-period data were acquired from most stations for the purpose of this study. Where there was appreciable diurnal variation in short-period noise, spectral data were computed for both day and night intervals. In most cases the long-period spectral densities were obtained by averagin the estimates from 16 data segments, each segment having a length of 2048 samples. Since the long-period sampling interval in 1 second, the total record length used was nearly 9.1 hours. In a few instances, a smaller number of segments was averaged. Spectral data were computed from the vertical-component short-period signals and all three components of long-period signals. All of the spectral plots have been corrected for known instrument response and presented in units of earth displacement. With a few exceptions, the samples of noise data used were acquired during the early months of 1980, winter at some of the stations and summer at others. The starting times for the intervals analyzed are listed in Table 1. A seasonal variation of noise levels in microseismic bands is to be expected. However, none of the stations were experiencing a noticeably high level of microseisms during the intervals analyzed. Weltman and others (1979) have studied and reported daily and seasonal RMS (root-mean-square) noise trends at the SRO and ASRO stations.
NASA Astrophysics Data System (ADS)
Pardo-Igúzquiza, Eulogio; Rodríguez-Tovar, Francisco J.
2012-12-01
Many spectral analysis techniques have been designed assuming sequences taken with a constant sampling interval. However, there are empirical time series in the geosciences (sediment cores, fossil abundance data, isotope analysis, …) that do not follow regular sampling because of missing data, gapped data, random sampling or incomplete sequences, among other reasons. In general, interpolating an uneven series in order to obtain a succession with a constant sampling interval alters the spectral content of the series. In such cases it is preferable to follow an approach that works with the uneven data directly, avoiding the need for an explicit interpolation step. The Lomb-Scargle periodogram is a popular choice in such circumstances, as there are programs available in the public domain for its computation. One new computer program for spectral analysis improves the standard Lomb-Scargle periodogram approach in two ways: (1) It explicitly adjusts the statistical significance to any bias introduced by variance reduction smoothing, and (2) it uses a permutation test to evaluate confidence levels, which is better suited than parametric methods when neighbouring frequencies are highly correlated. Another novel program for cross-spectral analysis offers the advantage of estimating the Lomb-Scargle cross-periodogram of two uneven time series defined on the same interval, and it evaluates the confidence levels of the estimated cross-spectra by a non-parametric computer intensive permutation test. Thus, the cross-spectrum, the squared coherence spectrum, the phase spectrum, and the Monte Carlo statistical significance of the cross-spectrum and the squared-coherence spectrum can be obtained. Both of the programs are written in ANSI Fortran 77, in view of its simplicity and compatibility. The program code is of public domain, provided on the website of the journal (http://www.iamg.org/index.php/publisher/articleview/frmArticleID/112/). Different examples (with simulated and real data) are described in this paper to corroborate the methodology and the implementation of these two new programs.
Liao, Xiang; Wang, Qing; Fu, Ji-hong; Tang, Jun
2015-09-01
This work was undertaken to establish a quantitative analysis model which can rapid determinate the content of linalool, linalyl acetate of Xinjiang lavender essential oil. Totally 165 lavender essential oil samples were measured by using near infrared absorption spectrum (NIR), after analyzing the near infrared spectral absorption peaks of all samples, lavender essential oil have abundant chemical information and the interference of random noise may be relatively low on the spectral intervals of 7100~4500 cm(-1). Thus, the PLS models was constructed by using this interval for further analysis. 8 abnormal samples were eliminated. Through the clustering method, 157 lavender essential oil samples were divided into 105 calibration set samples and 52 validation set samples. Gas chromatography mass spectrometry (GC-MS) was used as a tool to determine the content of linalool and linalyl acetate in lavender essential oil. Then the matrix was established with the GC-MS raw data of two compounds in combination with the original NIR data. In order to optimize the model, different pretreatment methods were used to preprocess the raw NIR spectral to contrast the spectral filtering effect, after analysizing the quantitative model results of linalool and linalyl acetate, the root mean square error prediction (RMSEP) of orthogonal signal transformation (OSC) was 0.226, 0.558, spectrally, it was the optimum pretreatment method. In addition, forward interval partial least squares (FiPLS) method was used to exclude the wavelength points which has nothing to do with determination composition or present nonlinear correlation, finally 8 spectral intervals totally 160 wavelength points were obtained as the dataset. Combining the data sets which have optimized by OSC-FiPLS with partial least squares (PLS) to establish a rapid quantitative analysis model for determining the content of linalool and linalyl acetate in Xinjiang lavender essential oil, numbers of hidden variables of two components were 8 in the model. The performance of the model was evaluated according to root mean square error of cross-validation (RMSECV), root mean square error of prediction (RMSEP). In the model, RESECV of linalool and linalyl acetate were 0.170 and 0.416, respectively; RM-SEP were 0.188 and 0.364. The results indicated that raw data was pretreated by OSC and FiPLS, the NIR-PLS quantitative analysis model with good robustness, high measurement precision; it could quickly determine the content of linalool and linalyl acetate in lavender essential oil. In addition, the model has a favorable prediction ability. The study also provide a new effective method which could rapid quantitative analysis the major components of Xinjiang lavender essential oil.
NASA Astrophysics Data System (ADS)
Wang, Xin; Tu, Chuanyi; Marsch, Eckart; He, Jiansen; Wang, Linghua
2016-01-01
Turbulence in the solar wind was recently reported to be anisotropic, with the average power spectral index close to -2 when sampling parallel to the local mean magnetic field B0 and close to -5/3 when sampling perpendicular to the local B0. This result was widely considered to be observational evidence for the critical balance theory (CBT), which is derived by making the assumption that the turbulence strength is close to one. However, this basic assumption has not yet been checked carefully with observational data. Here we present for the first time the scale-dependent magnetic-field fluctuation amplitude, which is normalized by the local B0 and evaluated for both parallel and perpendicular sampling directions, using two 30-day intervals of Ulysses data. From our results, the turbulence strength is evaluated as much less than one at small scales in the parallel direction. An even stricter criterion is imposed when selecting the wavelet coefficients for a given sampling direction, so that the time stationarity of the local B0 is better ensured during the local sampling interval. The spectral index for the parallel direction is then found to be -1.75, whereas the spectral index in the perpendicular direction remains close to -1.65. These two new results, namely that the value of the turbulence strength is much less than one in the parallel direction and that the angle dependence of the spectral index is weak, cannot be explained by existing turbulence theories, like CBT, and thus will require new theoretical considerations and promote further observations of solar-wind turbulence.
Lightning electromagnetic radiation field spectra in the interval from 0.2 to 20 MHz
NASA Technical Reports Server (NTRS)
Willett, J. C.; Bailey, J. C.; Leteinturier, C.; Krider, E. P.
1990-01-01
New Fourier transforms of wideband time-domain electric fields (E) produced by lightning (recorded at the Kennedy Space Center during the summers of 1985 and 1987) were recorded in such a way that several different events in each lightning flash could be captured. Average HF spectral amplitudes for first return strokes, stepped-leader steps, and 'characteristic pulses' are given for significantly more events, at closer ranges, and with better spectral resolution than in previous literature reports. The method of recording gives less bias toward the first large event in the flash and thus yields a large sample of a wide variety of lightning processes. As a result, reliable composite spectral amplitudes are obtained for a number of different processes in cloud-to-ground lightning over the frequency interval from 0.2 to 20 MHz.
de Oliveira, N; Joyeux, D; Phalippou, D; Rodier, J C; Polack, F; Vervloet, M; Nahon, L
2009-04-01
We describe a Fourier transform (FT) spectrometer designed to operate down to 60 nm (20 eV) on a synchrotron radiation beamline for high resolution absorption spectrometry. As far as we know, such an instrument is not available below 140 nm mainly because manufacturing accurate and efficient beam splitters remains a major problem at these wavelengths, especially if a wide bandwidth operation is desired. In order to overcome this difficulty, we developed an interferometer based on wave front division instead of amplitude division. It relies on a modified Fresnel bimirror configuration that requires only flat mirrors. The instrument provides path difference scanning through the translation of one reflector. During the scanning, the moving reflector is controlled by an optical system that keeps its direction constant within a tolerable value and provides an accurate interferometric measurement of the path difference variation. Therefore, a regular interferogram sampling is obtained, producing a nominal spectral impulse response and an accurate spectral calibration. The first results presented in this paper show a measured spectral resolution of delta(sigma)=0.33 cm-1 (interval between spectral samples). This was obtained with a sampling interval of 29 nm (path difference) and 512 K samples from a one-sided interferogram using a cosine FT. Such a sampling interval should allow the recording of large bandwidth spectra down to lambda=58 nm with an ultimate resolving power of 500,000 at this wavelength. In order to check the instrument performances, we first recorded an interferogram from a He-Ne stabilized laser. This provided the actual spectral impulse function, which was found to be fully satisfactory. The determination of the impulse response distortion and of the noise on the vacuum ultraviolet (VUV) spectral range provided accurate information in the sampling error profile over a typical scan. Finally, the instrument has been moved to the SU5 undulator-based synchrotron radiation beamline (Super-ACO facility, LURE, Orsay, France). A high resolution spectrum of O2 (the Schumann-Runge absorption bands, 185-200 nm) was computed from recorded interferograms using the beamline monochromator at the zeroth order to feed the instrument with an 11% relative bandwidth "white" beam (2003). These UV measurements are very close to those found in the literature, showing nominal performances of the FT spectrometer that should translate into an unprecedented resolving power at shortest VUV wavelengths. A recent upgrade (2007) and future developments will be discussed in light of the current installation of the upgraded FT spectrometer as a permanent endstation for ultrahigh resolution absorption spectrometry on the VUV beamline DESIRS at SOLEIL, the new French third generation synchrotron facility.
NASA Astrophysics Data System (ADS)
Zimnyakov, D. A.; Sinichkin, Yu P.; Ushakova, O. V.
2007-08-01
The results of theoretical analysis of the optical anisotropy of multiply scattering fibrillar biological tissues based on the model of an effective anisotropic medium are compared with the experimental in vivo birefringence data for the rat derma obtained earlier in spectral polarisation measurements of rat skin samples in the visible region. The disordered system of parallel dielectric cylinders embedded into an isotropic dielectric medium was considered as a model medium. Simulations were performed taking into account the influence of a partial mutual disordering of the bundles of collagen and elastin fibres in derma on birefringence in samples. The theoretical optical anisotropy averaged over the spectral interval 550-650 nm for the model medium with parameters corresponding to the structural parameters of derma is in good agreement with the results of spectral polarisation measurements of skin samples in the corresponding wavelength range.
Spectral signature selection for mapping unvegetated soils
NASA Technical Reports Server (NTRS)
May, G. A.; Petersen, G. W.
1975-01-01
Airborne multispectral scanner data covering the wavelength interval from 0.40-2.60 microns were collected at an altitude of 1000 m above the terrain in southeastern Pennsylvania. Uniform training areas were selected within three sites from this flightline. Soil samples were collected from each site and a procedure developed to allow assignment of scan line and element number from the multispectral scanner data to each sampling location. These soil samples were analyzed on a spectrophotometer and laboratory spectral signatures were derived. After correcting for solar radiation and atmospheric attenuation, the laboratory signatures were compared to the spectral signatures derived from these same soils using multispectral scanner data. Both signatures were used in supervised and unsupervised classification routines. Computer-generated maps using the laboratory and multispectral scanner derived signatures resulted in maps that were similar to maps resulting from field surveys. Approximately 90% agreement was obtained between classification maps produced using multispectral scanner derived signatures and laboratory derived signatures.
Zhong, Xinke; Labed, Jelila; Zhou, Guoqing; Shao, Kun; Li, Zhao-Liang
2015-01-01
The surface temperature (ST) of high-emissivity surfaces is an important parameter in climate systems. The empirical methods for retrieving ST for high-emissivity surfaces from hyperspectral thermal infrared (HypTIR) images require spectrally continuous channel data. This paper aims to develop a multi-channel method for retrieving ST for high-emissivity surfaces from space-borne HypTIR data. With an assumption of land surface emissivity (LSE) of 1, ST is proposed as a function of 10 brightness temperatures measured at the top of atmosphere by a radiometer having a spectral interval of 800–1200 cm−1 and a spectral sampling frequency of 0.25 cm−1. We have analyzed the sensitivity of the proposed method to spectral sampling frequency and instrumental noise, and evaluated the proposed method using satellite data. The results indicated that the parameters in the developed function are dependent on the spectral sampling frequency and that ST of high-emissivity surfaces can be accurately retrieved by the proposed method if appropriate values are used for each spectral sampling frequency. The results also showed that the accuracy of the retrieved ST is of the order of magnitude of the instrumental noise and that the root mean square error (RMSE) of the ST retrieved from satellite data is 0.43 K in comparison with the AVHRR SST product. PMID:26061199
da Silva, Fabiana E B; Flores, Érico M M; Parisotto, Graciele; Müller, Edson I; Ferrão, Marco F
2016-03-01
An alternative method for the quantification of sulphametoxazole (SMZ) and trimethoprim (TMP) using diffuse reflectance infrared Fourier-transform spectroscopy (DRIFTS) and partial least square regression (PLS) was developed. Interval Partial Least Square (iPLS) and Synergy Partial Least Square (siPLS) were applied to select a spectral range that provided the lowest prediction error in comparison to the full-spectrum model. Fifteen commercial tablet formulations and forty-nine synthetic samples were used. The ranges of concentration considered were 400 to 900 mg g-1SMZ and 80 to 240 mg g-1 TMP. Spectral data were recorded between 600 and 4000 cm-1 with a 4 cm-1 resolution by Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS). The proposed procedure was compared to high performance liquid chromatography (HPLC). The results obtained from the root mean square error of prediction (RMSEP), during the validation of the models for samples of sulphamethoxazole (SMZ) and trimethoprim (TMP) using siPLS, demonstrate that this approach is a valid technique for use in quantitative analysis of pharmaceutical formulations. The selected interval algorithm allowed building regression models with minor errors when compared to the full spectrum PLS model. A RMSEP of 13.03 mg g-1for SMZ and 4.88 mg g-1 for TMP was obtained after the selection the best spectral regions by siPLS.
NASA Technical Reports Server (NTRS)
Weismiller, R. A.; Mroczynski, R. P. (Principal Investigator)
1978-01-01
The author has identified the following significant results. Of the sampling techniques considered, a combination soil mapping and area sampling offered the most practical method for gathering soils data. Using the dot grid count, a relative percentage composition of soils can be calculated for each spectral class. From these percentages, a legend describing the dominant soils and inclusions can be developed. Interval drainage class seemed to be correlated with magnitude. For every parent material area, the more poorly drained soils had a lower magnitude of reflectance. Soil spectral classes seemed to be predominantly one internal drainage class.
Zhang, Ji; Li, Bing; Wang, Qi; Wei, Xin; Feng, Weibo; Chen, Yijiu; Huang, Ping; Wang, Zhenyuan
2017-12-21
Postmortem interval (PMI) evaluation remains a challenge in the forensic community due to the lack of efficient methods. Studies have focused on chemical analysis of biofluids for PMI estimation; however, no reports using spectroscopic methods in pericardial fluid (PF) are available. In this study, Fourier transform infrared (FTIR) spectroscopy with attenuated total reflectance (ATR) accessory was applied to collect comprehensive biochemical information from rabbit PF at different PMIs. The PMI-dependent spectral signature was determined by two-dimensional (2D) correlation analysis. The partial least square (PLS) and nu-support vector machine (nu-SVM) models were then established based on the acquired spectral dataset. Spectral variables associated with amide I, amide II, COO - , C-H bending, and C-O or C-OH vibrations arising from proteins, polypeptides, amino acids and carbohydrates, respectively, were susceptible to PMI in 2D correlation analysis. Moreover, the nu-SVM model appeared to achieve a more satisfactory prediction than the PLS model in calibration; the reliability of both models was determined in an external validation set. The study shows the possibility of application of ATR-FTIR methods in postmortem interval estimation using PF samples.
An Extension of the Time-Spectral Method to Overset Solvers
NASA Technical Reports Server (NTRS)
Leffell, Joshua Isaac; Murman, Scott M.; Pulliam, Thomas
2013-01-01
Relative motion in the Cartesian or overset framework causes certain spatial nodes to move in and out of the physical domain as they are dynamically blanked by moving solid bodies. This poses a problem for the conventional Time-Spectral approach, which expands the solution at every spatial node into a Fourier series spanning the period of motion. The proposed extension to the Time-Spectral method treats unblanked nodes in the conventional manner but expands the solution at dynamically blanked nodes in a basis of barycentric rational polynomials spanning partitions of contiguously defined temporal intervals. Rational polynomials avoid Runge's phenomenon on the equidistant time samples of these sub-periodic intervals. Fourier- and rational polynomial-based differentiation operators are used in tandem to provide a consistent hybrid Time-Spectral overset scheme capable of handling relative motion. The hybrid scheme is tested with a linear model problem and implemented within NASA's OVERFLOW Reynolds-averaged Navier- Stokes (RANS) solver. The hybrid Time-Spectral solver is then applied to inviscid and turbulent RANS cases of plunging and pitching airfoils and compared to time-accurate and experimental data. A limiter was applied in the turbulent case to avoid undershoots in the undamped turbulent eddy viscosity while maintaining accuracy. The hybrid scheme matches the performance of the conventional Time-Spectral method and converges to the time-accurate results with increased temporal resolution.
Imaging spectrometer measurement of water vapor in the 400 to 2500 nm spectral region
NASA Technical Reports Server (NTRS)
Green, Robert O.; Roberts, Dar A.; Conel, James E.; Dozier, Jeff
1995-01-01
The Airborne Visible-Infrared Imaging Spectrometer (AVIRIS) measures the total upwelling spectral radiance from 400 to 2500 nm sampled at 10 nm intervals. The instrument acquires spectral data at an altitude of 20 km above sea level, as images of 11 by up to 100 km at 17x17 meter spatial sampling. We have developed a nonlinear spectral fitting algorithm coupled with a radiative transfer code to derive the total path water vapor from the spectrum, measured for each spatial element in an AVIRIS image. The algorithm compensates for variation in the surface spectral reflectance and atmospheric aerosols. It uses water vapor absorption bands centered at 940 nm, 1040 nm, and 1380 nm. We analyze data sets with water vapor abundances ranging from 1 to 40 perceptible millimeters. In one data set, the total path water vapor varies from 7 to 21 mm over a distance of less than 10 km. We have analyzed a time series of five images acquired at 12 minute intervals; these show spatially heterogeneous changes of advocated water vapor of 25 percent over 1 hour. The algorithm determines water vapor for images with a range of ground covers, including bare rock and soil, sparse to dense vegetation, snow and ice, open water, and clouds. The precision of the water vapor determination approaches one percent. However, the precision is sensitive to the absolute abundance and the absorption strength of the atmospheric water vapor band analyzed. We have evaluated the accuracy of the algorithm by comparing several surface-based determinations of water vapor at the time of the AVIRIS data acquisition. The agreement between the AVIRIS measured water vapor and the in situ surface radiometer and surface interferometer measured water vapor is 5 to 10 percent.
Thermal Infrared Spectral Band Detection Limits for Unidentified Surface Materials
NASA Technical Reports Server (NTRS)
Kirkland, Laurel E.; Herr, Kenneth C.; Salisbury, John W.
2001-01-01
Infrared emission spectra recorded by airborne or satellite spectrometers can be searched for spectral features to determine the composition of rocks on planetary surfaces. Surface materials are identified by detections of characteristic spectral bands. We show how to define whether to accept an observed spectral feature as a detection when the target material is unknown. We also use remotely sensed spectra measured by the Thermal Emission Spectrometer (TES) and the Spatially Enhanced Broadband Array Spectrograph System to illustrate the importance of instrument parameters and surface properties on band detection limits and how the variation in signal-to-noise ratio with wavelength affects the bands that are most detectable for a given instrument. The spectrometer's sampling interval, spectral resolution, signal-to-noise ratio as a function of wavelength, and the sample's surface properties influence whether the instrument can detect a spectral feature exhibited by a material. As an example, in the 6-13 micrometer wavelength region, massive carbonates exhibit two bands: a very strong, broad feature at approximately 6.5 micrometers and a less intense, sharper band at approximately 11.25 micrometers. Although the 6.5-micrometer band is stronger and broader in laboratory-measured spectra, the 11.25-micrometer band will cause a more detectable feature in TES spectra.
Software algorithm and hardware design for real-time implementation of new spectral estimator
2014-01-01
Background Real-time spectral analyzers can be difficult to implement for PC computer-based systems because of the potential for high computational cost, and algorithm complexity. In this work a new spectral estimator (NSE) is developed for real-time analysis, and compared with the discrete Fourier transform (DFT). Method Clinical data in the form of 216 fractionated atrial electrogram sequences were used as inputs. The sample rate for acquisition was 977 Hz, or approximately 1 millisecond between digital samples. Real-time NSE power spectra were generated for 16,384 consecutive data points. The same data sequences were used for spectral calculation using a radix-2 implementation of the DFT. The NSE algorithm was also developed for implementation as a real-time spectral analyzer electronic circuit board. Results The average interval for a single real-time spectral calculation in software was 3.29 μs for NSE versus 504.5 μs for DFT. Thus for real-time spectral analysis, the NSE algorithm is approximately 150× faster than the DFT. Over a 1 millisecond sampling period, the NSE algorithm had the capability to spectrally analyze a maximum of 303 data channels, while the DFT algorithm could only analyze a single channel. Moreover, for the 8 second sequences, the NSE spectral resolution in the 3-12 Hz range was 0.037 Hz while the DFT spectral resolution was only 0.122 Hz. The NSE was also found to be implementable as a standalone spectral analyzer board using approximately 26 integrated circuits at a cost of approximately $500. The software files used for analysis are included as a supplement, please see the Additional files 1 and 2. Conclusions The NSE real-time algorithm has low computational cost and complexity, and is implementable in both software and hardware for 1 millisecond updates of multichannel spectra. The algorithm may be helpful to guide radiofrequency catheter ablation in real time. PMID:24886214
Fourier-transform infrared derivative spectroscopy with an improved signal-to-noise ratio.
Fetterman, M R
2005-09-01
Infrared derivative spectroscopy is a useful technique for finding peaks hidden in broad spectral features. A data acquisition technique is shown that will improve the signal-to-noise ratio (SNR) of Fourier-transform infrared (FTIR) derivative spectroscopy. Typically, in a FTIR measurement one samples each point for the same time interval. The effect of using a graded time interval is studied. The simulations presented show that the SNR of first-derivative FTIR spectroscopy will improve by 15% and that the SNR of second-derivative FTIR will improve by 34%.
Golightly, D.W.; Dorrzapf, A.F.; Thomas, C.P.
1977-01-01
Sets of 5 Fe(I) lines and 3 Ti(I)Ti(II) line pairs have been characterized for precise spectrographic thermometry and manometry, respectively, in d.c. arcs of geologic materials. The recommended lines are free of spectral interferences, exhibit minimal self absorption within defined concentration intervals, and are useful for chemically-unaltered silicate rocks, arced in an argon-oxygen stream. The functional character of these lines in thermometry and manometry of d.c. arcs for evaluations of electrical parameter effects, for temporal studies, and for matrix-effect investigations on real samples is illustrated. ?? 1977.
Soil Organic Carbon Estimation and Mapping Using "on-the-go" VisNIR Spectroscopy
NASA Astrophysics Data System (ADS)
Brown, D. J.; Bricklemyer, R. S.; Christy, C.
2007-12-01
Soil organic carbon (SOC) and other soil properties related to carbon sequestration (eg. soil clay content and mineralogy) vary spatially across landscapes. To cost effectively capture this variability, new technologies, such as Visible and Near Infrared (VisNIR) spectroscopy, have been applied to soils for rapid, accurate, and inexpensive estimation of SOC and other soil properties. For this study, we evaluated an "on the go" VisNIR sensor developed by Veris Technologies, Inc. (Salinas, KS) for mapping SOC, soil clay content and mineralogy. The Veris spectrometer spanned 350 to 2224 nm with 8 nm spectral resolution, and 25 spectra were integrated every 2 seconds resulting in 3 -5 m scanning distances on the ground. The unit was mounted to a mobile sensor platform pulled by a tractor, and scanned soils at an average depth of 10 cm through a quartz-sapphire window. We scanned eight 16.2 ha (40 ac) wheat fields in north central Montana (USA), with 15 m transect intervals. Using random sampling with spatial inhibition, 100 soil samples from 0-10 cm depths were extracted along scanned transects from each field and were analyzed for SOC. Neat, sieved (<2 mm) soil sample materials were also scanned in the lab using an Analytical Spectral Devices (ASD, Boulder, CO, USA) Fieldspec Pro FR spectroradiometer with a spectral range of 350-2500 and spectral resolution of 2-10 nm. The analyzed samples were used to calibrate and validate a number of partial least squares regression (PLSR) VisNIR models to compare on-the-go scanning vs. higher spectral resolution laboratory spectroscopy vs. standard SOC measurement methods.
NASA Technical Reports Server (NTRS)
Bailey, Gary C.
1987-01-01
The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) instrument uses four separate focal plane assemblies consisting of line array detectors that are multiplexed to a common J-FET preamp using a FET switch multiplexing (MUX) technique. A 32-element silicon line array covers the spectral range from 0.41 to 0.70 microns. Three additional 64-element indium antimonide (InSb) line arrays cover the spectral range from 0.68 to 2.45 microns. The spectral sampling interval per detector element is nominally 9.8 nm, giving a total of 224 spectral channels. All focal planes operate at liquid nitrogen temperature and are housed in separate dewars. Electrical performance characteristics include a read noise of less than 1000 e(-) in all channels, response and dark nonuniformity of 5 percent peak to peak, and quantum efficiency of greater than 60 percent.
Genkawa, Takuma; Shinzawa, Hideyuki; Kato, Hideaki; Ishikawa, Daitaro; Murayama, Kodai; Komiyama, Makoto; Ozaki, Yukihiro
2015-12-01
An alternative baseline correction method for diffuse reflection near-infrared (NIR) spectra, searching region standard normal variate (SRSNV), was proposed. Standard normal variate (SNV) is an effective pretreatment method for baseline correction of diffuse reflection NIR spectra of powder and granular samples; however, its baseline correction performance depends on the NIR region used for SNV calculation. To search for an optimal NIR region for baseline correction using SNV, SRSNV employs moving window partial least squares regression (MWPLSR), and an optimal NIR region is identified based on the root mean square error (RMSE) of cross-validation of the partial least squares regression (PLSR) models with the first latent variable (LV). The performance of SRSNV was evaluated using diffuse reflection NIR spectra of mixture samples consisting of wheat flour and granular glucose (0-100% glucose at 5% intervals). From the obtained NIR spectra of the mixture in the 10 000-4000 cm(-1) region at 4 cm intervals (1501 spectral channels), a series of spectral windows consisting of 80 spectral channels was constructed, and then SNV spectra were calculated for each spectral window. Using these SNV spectra, a series of PLSR models with the first LV for glucose concentration was built. A plot of RMSE versus the spectral window position obtained using the PLSR models revealed that the 8680–8364 cm(-1) region was optimal for baseline correction using SNV. In the SNV spectra calculated using the 8680–8364 cm(-1) region (SRSNV spectra), a remarkable relative intensity change between a band due to wheat flour at 8500 cm(-1) and that due to glucose at 8364 cm(-1) was observed owing to successful baseline correction using SNV. A PLSR model with the first LV based on the SRSNV spectra yielded a determination coefficient (R2) of 0.999 and an RMSE of 0.70%, while a PLSR model with three LVs based on SNV spectra calculated in the full spectral region gave an R2 of 0.995 and an RMSE of 2.29%. Additional evaluation of SRSNV was carried out using diffuse reflection NIR spectra of marzipan and corn samples, and PLSR models based on SRSNV spectra showed good prediction results. These evaluation results indicate that SRSNV is effective in baseline correction of diffuse reflection NIR spectra and provides regression models with good prediction accuracy.
Melkonian, D; Korner, A; Meares, R; Bahramali, H
2012-10-01
A novel method of the time-frequency analysis of non-stationary heart rate variability (HRV) is developed which introduces the fragmentary spectrum as a measure that brings together the frequency content, timing and duration of HRV segments. The fragmentary spectrum is calculated by the similar basis function algorithm. This numerical tool of the time to frequency and frequency to time Fourier transformations accepts both uniform and non-uniform sampling intervals, and is applicable to signal segments of arbitrary length. Once the fragmentary spectrum is calculated, the inverse transform recovers the original signal and reveals accuracy of spectral estimates. Numerical experiments show that discontinuities at the boundaries of the succession of inter-beat intervals can cause unacceptable distortions of the spectral estimates. We have developed a measure that we call the "RR deltagram" as a form of the HRV data that minimises spectral errors. The analysis of the experimental HRV data from real-life and controlled breathing conditions suggests transient oscillatory components as functionally meaningful elements of highly complex and irregular patterns of HRV. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Assuring the required spectroradiometric characteristics of the Fragment multispectral system
NASA Astrophysics Data System (ADS)
Bogdanov, A. A.; Kuzmin, V. I.; Mosevnina, L. G.; Popkov, A. V.; Sychev, A. G.; Tarnopolskii, V. I.
The paper examines methods and equipment for assuring the required spectroradiometric characteristics of the satellite-borne Fragment multispectral scanning system during development, fabrication, and autonomous and complex testing. These characteristics comprise: (1) the integrated sensitivity of the measuring channels to the spectral density of brightness (SDB): (2) the relative spectral sensitivity of the channels; (3) the effective spectral width of the sensitivity intervals and their position in the spectral range; (4) maximum values of SDB measured by the system in each spectral interval of sensitivity; (5) the SNR in each measuring channel; and (6) the relative rms of SDB measurements.
Nonuniform sampling and non-Fourier signal processing methods in multidimensional NMR
Mobli, Mehdi; Hoch, Jeffrey C.
2017-01-01
Beginning with the introduction of Fourier Transform NMR by Ernst and Anderson in 1966, time domain measurement of the impulse response (the free induction decay, FID) consisted of sampling the signal at a series of discrete intervals. For compatibility with the discrete Fourier transform (DFT), the intervals are kept uniform, and the Nyquist theorem dictates the largest value of the interval sufficient to avoid aliasing. With the proposal by Jeener of parametric sampling along an indirect time dimension, extension to multidimensional experiments employed the same sampling techniques used in one dimension, similarly subject to the Nyquist condition and suitable for processing via the discrete Fourier transform. The challenges of obtaining high-resolution spectral estimates from short data records using the DFT were already well understood, however. Despite techniques such as linear prediction extrapolation, the achievable resolution in the indirect dimensions is limited by practical constraints on measuring time. The advent of non-Fourier methods of spectrum analysis capable of processing nonuniformly sampled data has led to an explosion in the development of novel sampling strategies that avoid the limits on resolution and measurement time imposed by uniform sampling. The first part of this review discusses the many approaches to data sampling in multidimensional NMR, the second part highlights commonly used methods for signal processing of such data, and the review concludes with a discussion of other approaches to speeding up data acquisition in NMR. PMID:25456315
Human autonomic rhythms: vagal cardiac mechanisms in tetraplegic subjects
NASA Technical Reports Server (NTRS)
Koh, J.; Brown, T. E.; Beightol, L. A.; Ha, C. Y.; Eckberg, D. L.
1994-01-01
1. We studied eight young men (age range: 20-37 years) with chronic, clinically complete high cervical spinal cord injuries and ten age-matched healthy men to determine how interruption of connections between the central nervous system and spinal sympathetic motoneurones affects autonomic cardiovascular control. 2. Baseline diastolic pressures and R-R intervals (heart periods) were similar in the two groups. Slopes of R-R interval responses to brief neck pressure changes were significantly lower in tetraplegic than in healthy subjects, but slopes of R-R interval responses to steady-state arterial pressure reductions and increases were comparable. Plasma noradrenaline levels did not change significantly during steady-state arterial pressure reductions in tetraplegic patients, but rose sharply in healthy subjects. The range of arterial pressure and R-R interval responses to vasoactive drugs (nitroprusside and phenylephrine) was significantly greater in tetraplegic than healthy subjects. 3. Resting R-R interval spectral power at respiratory and low frequencies was similar in the two groups. During infusions of vasoactive drugs, low-frequency R-R interval spectral power was directly proportional to arterial pressure in tetraplegic patients, but was unrelated to arterial pressure in healthy subjects. Vagolytic doses of atropine nearly abolished both low- and respiratory-frequency R-R interval spectral power in both groups. 4. Our conclusions are as follows. First, since tetraplegic patients have significant levels of low-frequency arterial pressure and R-R interval spectral power, human Mayer arterial pressure waves may result from mechanisms that do not involve stimulation of spinal sympathetic motoneurones by brainstem neurones. Second, since in tetraplegic patients, low-frequency R-R interval spectral power is proportional to arterial pressure, it is likely to be mediated by a baroreflex mechanism. Third, since low-frequency R-R interval rhythms were nearly abolished by atropine in both tetraplegic and healthy subjects, these rhythms reflect in an important way rhythmic firing of vagal cardiac motoneurones.
Perez-Guaita, David; Kuligowski, Julia; Quintás, Guillermo; Garrigues, Salvador; Guardia, Miguel de la
2013-03-30
Locally weighted partial least squares regression (LW-PLSR) has been applied to the determination of four clinical parameters in human serum samples (total protein, triglyceride, glucose and urea contents) by Fourier transform infrared (FTIR) spectroscopy. Classical LW-PLSR models were constructed using different spectral regions. For the selection of parameters by LW-PLSR modeling, a multi-parametric study was carried out employing the minimum root-mean square error of cross validation (RMSCV) as objective function. In order to overcome the effect of strong matrix interferences on the predictive accuracy of LW-PLSR models, this work focuses on sample selection. Accordingly, a novel strategy for the development of local models is proposed. It was based on the use of: (i) principal component analysis (PCA) performed on an analyte specific spectral region for identifying most similar sample spectra and (ii) partial least squares regression (PLSR) constructed using the whole spectrum. Results found by using this strategy were compared to those provided by PLSR using the same spectral intervals as for LW-PLSR. Prediction errors found by both, classical and modified LW-PLSR improved those obtained by PLSR. Hence, both proposed approaches were useful for the determination of analytes present in a complex matrix as in the case of human serum samples. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kroenke, Samantha E.
In June 2009, a 2.2 square mile 3-D high resolution seismic reflection survey was shot in southeastern Illinois in the Phillipstown Consolidated oilfield. A well was drilled in the 3-D survey area to tie the seismic to the geological data with a synthetic seismogram from the sonic log. The objectives of the 3-D seismic survey were three-fold: (1) To image and interpret faulting of the Herald-Phillipstown Fault using drillhole-based geological and seismic cross-sections and structural contour maps created from the drillhole data and seismic reflection data, (2) To test the effectiveness of imaging the faults by selected seismic attributes, and (3) To compare spectral decomposition amplitude maps with an isochron map and an isopach map of a selected geologic interval (VTG interval). Drillhole and seismic reflection data show that various formation offsets increase near the main Herald-Phillipstown fault, and that the fault and its large offset subsidiary faults penetrate the Precambrian crystalline basement. A broad, northeast-trending 10,000 feet wide graben is consistently observed in the drillhole data. Both shallow and deep formations in the geological cross-sections reveal small horst and graben features within the broad graben created possibly in response to fault reactivations. The HPF faults have been interpreted as originally Precambrian age high-angle, normal faults reactivated with various amounts and types of offset. Evidence for strike-slip movement is also clear on several faults. Changes in the seismic attribute values in the selected interval and along various time slices throughout the whole dataset correlate with the Herald-Phillipstown faults. Overall, seismic attributes could provide a means of mapping large offset faults in areas with limited or absent drillhole data. Results of the spectral decomposition suggest that if the interval velocity is known for a particular formation or interval, high-resolution 3-D seismic reflection surveys could utilize these amplitudes as an alternative seismic interpretation method for estimating formation thicknesses. A VTG isopach map was compared with an isochron map and a spectral decomposition amplitude map. The results reveal that the isochron map strongly correlates with the isopach map as well as the spectral decomposition map. It was also found that thicker areas in the isopach correlated with higher amplitude values in the spectral decomposition amplitude map. Offsets along the faults appear sharper in these amplitudes and isochron maps than in the isopach map, possibly as a result of increased spatial sampling.
Relationship between behavioral and physiological spectral-ripple discrimination.
Won, Jong Ho; Clinard, Christopher G; Kwon, Seeyoun; Dasika, Vasant K; Nie, Kaibao; Drennan, Ward R; Tremblay, Kelly L; Rubinstein, Jay T
2011-06-01
Previous studies have found a significant correlation between spectral-ripple discrimination and speech and music perception in cochlear implant (CI) users. This relationship could be of use to clinicians and scientists who are interested in using spectral-ripple stimuli in the assessment and habilitation of CI users. However, previous psychoacoustic tasks used to assess spectral discrimination are not suitable for all populations, and it would be beneficial to develop methods that could be used to test all age ranges, including pediatric implant users. Additionally, it is important to understand how ripple stimuli are processed in the central auditory system and how their neural representation contributes to behavioral performance. For this reason, we developed a single-interval, yes/no paradigm that could potentially be used both behaviorally and electrophysiologically to estimate spectral-ripple threshold. In experiment 1, behavioral thresholds obtained using the single-interval method were compared to thresholds obtained using a previously established three-alternative forced-choice method. A significant correlation was found (r = 0.84, p = 0.0002) in 14 adult CI users. The spectral-ripple threshold obtained using the new method also correlated with speech perception in quiet and noise. In experiment 2, the effect of the number of vocoder-processing channels on the behavioral and physiological threshold in normal-hearing listeners was determined. Behavioral thresholds, using the new single-interval method, as well as cortical P1-N1-P2 responses changed as a function of the number of channels. Better behavioral and physiological performance (i.e., better discrimination ability at higher ripple densities) was observed as more channels added. In experiment 3, the relationship between behavioral and physiological data was examined. Amplitudes of the P1-N1-P2 "change" responses were significantly correlated with d' values from the single-interval behavioral procedure. Results suggest that the single-interval procedure with spectral-ripple phase inversion in ongoing stimuli is a valid approach for measuring behavioral or physiological spectral resolution.
Accelerometer Data Analysis and Presentation Techniques
NASA Technical Reports Server (NTRS)
Rogers, Melissa J. B.; Hrovat, Kenneth; McPherson, Kevin; Moskowitz, Milton E.; Reckart, Timothy
1997-01-01
The NASA Lewis Research Center's Principal Investigator Microgravity Services project analyzes Orbital Acceleration Research Experiment and Space Acceleration Measurement System data for principal investigators of microgravity experiments. Principal investigators need a thorough understanding of data analysis techniques so that they can request appropriate analyses to best interpret accelerometer data. Accelerometer data sampling and filtering is introduced along with the related topics of resolution and aliasing. Specific information about the Orbital Acceleration Research Experiment and Space Acceleration Measurement System data sampling and filtering is given. Time domain data analysis techniques are discussed and example environment interpretations are made using plots of acceleration versus time, interval average acceleration versus time, interval root-mean-square acceleration versus time, trimmean acceleration versus time, quasi-steady three dimensional histograms, and prediction of quasi-steady levels at different locations. An introduction to Fourier transform theory and windowing is provided along with specific analysis techniques and data interpretations. The frequency domain analyses discussed are power spectral density versus frequency, cumulative root-mean-square acceleration versus frequency, root-mean-square acceleration versus frequency, one-third octave band root-mean-square acceleration versus frequency, and power spectral density versus frequency versus time (spectrogram). Instructions for accessing NASA Lewis Research Center accelerometer data and related information using the internet are provided.
Nonuniform sampling and non-Fourier signal processing methods in multidimensional NMR.
Mobli, Mehdi; Hoch, Jeffrey C
2014-11-01
Beginning with the introduction of Fourier Transform NMR by Ernst and Anderson in 1966, time domain measurement of the impulse response (the free induction decay, FID) consisted of sampling the signal at a series of discrete intervals. For compatibility with the discrete Fourier transform (DFT), the intervals are kept uniform, and the Nyquist theorem dictates the largest value of the interval sufficient to avoid aliasing. With the proposal by Jeener of parametric sampling along an indirect time dimension, extension to multidimensional experiments employed the same sampling techniques used in one dimension, similarly subject to the Nyquist condition and suitable for processing via the discrete Fourier transform. The challenges of obtaining high-resolution spectral estimates from short data records using the DFT were already well understood, however. Despite techniques such as linear prediction extrapolation, the achievable resolution in the indirect dimensions is limited by practical constraints on measuring time. The advent of non-Fourier methods of spectrum analysis capable of processing nonuniformly sampled data has led to an explosion in the development of novel sampling strategies that avoid the limits on resolution and measurement time imposed by uniform sampling. The first part of this review discusses the many approaches to data sampling in multidimensional NMR, the second part highlights commonly used methods for signal processing of such data, and the review concludes with a discussion of other approaches to speeding up data acquisition in NMR. Copyright © 2014 Elsevier B.V. All rights reserved.
Matrix Sturm-Liouville equation with a Bessel-type singularity on a finite interval
NASA Astrophysics Data System (ADS)
Bondarenko, Natalia
2017-03-01
The matrix Sturm-Liouville equation on a finite interval with a Bessel-type singularity in the end of the interval is studied. Special fundamental systems of solutions for this equation are constructed: analytic Bessel-type solutions with the prescribed behavior at the singular point and Birkhoff-type solutions with the known asymptotics for large values of the spectral parameter. The asymptotic formulas for Stokes multipliers, connecting these two fundamental systems of solutions, are derived. We also set boundary conditions and obtain asymptotic formulas for the spectral data (the eigenvalues and the weight matrices) of the boundary value problem. Our results will be useful in the theory of direct and inverse spectral problems.
Accounting for Sampling Error in Genetic Eigenvalues Using Random Matrix Theory.
Sztepanacz, Jacqueline L; Blows, Mark W
2017-07-01
The distribution of genetic variance in multivariate phenotypes is characterized by the empirical spectral distribution of the eigenvalues of the genetic covariance matrix. Empirical estimates of genetic eigenvalues from random effects linear models are known to be overdispersed by sampling error, where large eigenvalues are biased upward, and small eigenvalues are biased downward. The overdispersion of the leading eigenvalues of sample covariance matrices have been demonstrated to conform to the Tracy-Widom (TW) distribution. Here we show that genetic eigenvalues estimated using restricted maximum likelihood (REML) in a multivariate random effects model with an unconstrained genetic covariance structure will also conform to the TW distribution after empirical scaling and centering. However, where estimation procedures using either REML or MCMC impose boundary constraints, the resulting genetic eigenvalues tend not be TW distributed. We show how using confidence intervals from sampling distributions of genetic eigenvalues without reference to the TW distribution is insufficient protection against mistaking sampling error as genetic variance, particularly when eigenvalues are small. By scaling such sampling distributions to the appropriate TW distribution, the critical value of the TW statistic can be used to determine if the magnitude of a genetic eigenvalue exceeds the sampling error for each eigenvalue in the spectral distribution of a given genetic covariance matrix. Copyright © 2017 by the Genetics Society of America.
Holland, Alexander; Aboy, Mateo
2009-07-01
We present a novel method to iteratively calculate discrete Fourier transforms for discrete time signals with sample time intervals that may be widely nonuniform. The proposed recursive Fourier transform (RFT) does not require interpolation of the samples to uniform time intervals, and each iterative transform update of N frequencies has computational order N. Because of the inherent non-uniformity in the time between successive heart beats, an application particularly well suited for this transform is power spectral density (PSD) estimation for heart rate variability. We compare RFT based spectrum estimation with Lomb-Scargle Transform (LST) based estimation. PSD estimation based on the LST also does not require uniform time samples, but the LST has a computational order greater than Nlog(N). We conducted an assessment study involving the analysis of quasi-stationary signals with various levels of randomly missing heart beats. Our results indicate that the RFT leads to comparable estimation performance to the LST with significantly less computational overhead and complexity for applications requiring iterative spectrum estimations.
Spectral types for objects in the Kiso survey. IV - Data for 81 stars
NASA Technical Reports Server (NTRS)
Wegner, Gary; Mcmahan, Robert K.
1988-01-01
Spectroscopy and spectral types for 81 ultraviolet-excess objects found in the Kiso Schmidt-camera survey are reported. The data were secured with the McGraw-Hill 1.3 m telescope at 8-A resolution covering the wavelength interval 4000 -7200 A using the Mark II spectrograph. Descriptions of the spectra of some of the more peculiar objects found in this sample are given and include 14 sub-dwarfs, 23 definite DA white dwarfs, including a magnetic one, and one DQ whie dwarf, eight quasars and emission-line objects, and a new composite DA + dM system. More spectroscopy of the new cataclysmic variable KUV 01584-0939 and a possibly related object is also described.
NASA Astrophysics Data System (ADS)
Panteleev, Ivan; Bayandin, Yuriy; Naimark, Oleg
2017-12-01
This work performs a correlation analysis of the statistical properties of continuous acoustic emission recorded in different parts of marble and fiberglass laminate samples under quasi-static deformation. A spectral coherent measure of time series, which is a generalization of the squared coherence spectrum on a multidimensional series, was chosen. The spectral coherent measure was estimated in a sliding time window for two parameters of the acoustic emission multifractal singularity spectrum: the spectrum width and the generalized Hurst exponent realizing the maximum of the singularity spectrum. It is shown that the preparation of the macrofracture focus is accompanied by the synchronization (coherent behavior) of the statistical properties of acoustic emission in allocated frequency intervals.
Remote Sensing of Plastic Debris
NASA Astrophysics Data System (ADS)
Garaba, S. P.; Dierssen, H. M.
2016-02-01
Plastic debris is becoming a nuisance in the environment and as a result there has been a dire need to synoptically detect and quantify them in the ocean and on land. We investigate the possible utility of spectral information determined from hand held, airborne and satellite remote sensing tools in the detection and identification polymer source of plastic debris. Sampled debris will be compared to our derived spectral library of typical raw polymer sources found at sea and in household waste. Additional work will be to determine ways to estimate the abundance of plastic debris in target areas. Implications of successful remote detection, tracking and quantification of plastic debris will be towards validating field observations over large areas and at repeated time intervals both on land and at sea.
Contamination of the 5394 Å spectral region by telluric lines
NASA Astrophysics Data System (ADS)
Vince, I.; Vince, O.
2010-11-01
The spectral region in the vicinity of 5394 Å contains three prominent photospheric spectral lines, which can be used as a solar plasma diagnostic tool. The occurrence of telluric lines in this region is a potential source of systematic and random errors in these solar spectral lines. The goal of our investigation was to determine the telluric line contamination of this interesting spectral region. Several series of high-resolution solar spectra within an interval of about 4 Å around the 5394 Å wavelength were observed at different zenith distances of the Sun. Comparison of these spectra has permitted identification of telluric lines in this spectral interval. The observations were carried out with the horizontal solar spectrograph of the Heliophysical Observatory in Debrecen. Telluric feature blending was identified in the blue and red wings of the Fe I 5393.2 Å line, and in the local continuum of the Mn I 5394.7 Å line. The blue wing of the Fe I 5395.2 Å line is contaminated by a weak telluric feature too. The red continuum of this line has a more prominent telluric contamination. A dozen of water vapor telluric lines that determined the observed telluric features were identified in this spectral interval. The profiles of three telluric lines that have a significant influence on both the profiles of solar spectral lines and the level of local continuum were derived, and the variation of their parameters (equivalent width and central depth) with air mass were analyzed.
Stilp, Christian E.; Goupell, Matthew J.
2015-01-01
Short-time spectral changes in the speech signal are important for understanding noise-vocoded sentences. These information-bearing acoustic changes, measured using cochlea-scaled entropy in cochlear implant simulations [CSECI; Stilp et al. (2013). J. Acoust. Soc. Am. 133(2), EL136–EL141; Stilp (2014). J. Acoust. Soc. Am. 135(3), 1518–1529], may offer better understanding of speech perception by cochlear implant (CI) users. However, perceptual importance of CSECI for normal-hearing listeners was tested at only one spectral resolution and one temporal resolution, limiting generalizability of results to CI users. Here, experiments investigated the importance of these informational changes for understanding noise-vocoded sentences at different spectral resolutions (4–24 spectral channels; Experiment 1), temporal resolutions (4–64 Hz cutoff for low-pass filters that extracted amplitude envelopes; Experiment 2), or when both parameters varied (6–12 channels, 8–32 Hz; Experiment 3). Sentence intelligibility was reduced more by replacing high-CSECI intervals with noise than replacing low-CSECI intervals, but only when sentences had sufficient spectral and/or temporal resolution. High-CSECI intervals were more important for speech understanding as spectral resolution worsened and temporal resolution improved. Trade-offs between CSECI and intermediate spectral and temporal resolutions were minimal. These results suggest that signal processing strategies that emphasize information-bearing acoustic changes in speech may improve speech perception for CI users. PMID:25698018
NASA Technical Reports Server (NTRS)
Rutledge, Charles K.
1988-01-01
The validity of applying chi-square based confidence intervals to far-field acoustic flyover spectral estimates was investigated. Simulated data, using a Kendall series and experimental acoustic data from the NASA/McDonnell Douglas 500E acoustics test, were analyzed. Statistical significance tests to determine the equality of distributions of the simulated and experimental data relative to theoretical chi-square distributions were performed. Bias and uncertainty errors associated with the spectral estimates were easily identified from the data sets. A model relating the uncertainty and bias errors to the estimates resulted, which aided in determining the appropriateness of the chi-square distribution based confidence intervals. Such confidence intervals were appropriate for nontonally associated frequencies of the experimental data but were inappropriate for tonally associated estimate distributions. The appropriateness at the tonally associated frequencies was indicated by the presence of bias error and noncomformity of the distributions to the theoretical chi-square distribution. A technique for determining appropriate confidence intervals at the tonally associated frequencies was suggested.
NASA Astrophysics Data System (ADS)
Zhang, Qian; Harman, Ciaran J.; Kirchner, James W.
2018-02-01
River water-quality time series often exhibit fractal scaling, which here refers to autocorrelation that decays as a power law over some range of scales. Fractal scaling presents challenges to the identification of deterministic trends because (1) fractal scaling has the potential to lead to false inference about the statistical significance of trends and (2) the abundance of irregularly spaced data in water-quality monitoring networks complicates efforts to quantify fractal scaling. Traditional methods for estimating fractal scaling - in the form of spectral slope (β) or other equivalent scaling parameters (e.g., Hurst exponent) - are generally inapplicable to irregularly sampled data. Here we consider two types of estimation approaches for irregularly sampled data and evaluate their performance using synthetic time series. These time series were generated such that (1) they exhibit a wide range of prescribed fractal scaling behaviors, ranging from white noise (β = 0) to Brown noise (β = 2) and (2) their sampling gap intervals mimic the sampling irregularity (as quantified by both the skewness and mean of gap-interval lengths) in real water-quality data. The results suggest that none of the existing methods fully account for the effects of sampling irregularity on β estimation. First, the results illustrate the danger of using interpolation for gap filling when examining autocorrelation, as the interpolation methods consistently underestimate or overestimate β under a wide range of prescribed β values and gap distributions. Second, the widely used Lomb-Scargle spectral method also consistently underestimates β. A previously published modified form, using only the lowest 5 % of the frequencies for spectral slope estimation, has very poor precision, although the overall bias is small. Third, a recent wavelet-based method, coupled with an aliasing filter, generally has the smallest bias and root-mean-squared error among all methods for a wide range of prescribed β values and gap distributions. The aliasing method, however, does not itself account for sampling irregularity, and this introduces some bias in the result. Nonetheless, the wavelet method is recommended for estimating β in irregular time series until improved methods are developed. Finally, all methods' performances depend strongly on the sampling irregularity, highlighting that the accuracy and precision of each method are data specific. Accurately quantifying the strength of fractal scaling in irregular water-quality time series remains an unresolved challenge for the hydrologic community and for other disciplines that must grapple with irregular sampling.
NASA Astrophysics Data System (ADS)
Teimoorinia, H.
2012-12-01
The aim of this work is to combine spectral energy distribution (SED) fitting with artificial neural network techniques to assign spectral characteristics to a sample of galaxies at 0.5 < z < 1. The sample is selected from the spectroscopic campaign of the ESO/GOODS-South field, with 142 sources having photometric data from the GOODS-MUSIC catalog covering bands between ~0.4 and 24 μm in 10-13 filters. We use the CIGALE code to fit photometric data to Maraston's synthesis spectra to derive mass, specific star formation rate, and age, as well as the best SED of the galaxies. We use the spectral models presented by Kinney et al. as targets in the wavelength interval ~1200-7500 Å. Then a series of neural networks are trained, with average performance ~90%, to classify the best SED in a supervised manner. We consider the effects of the prominent features of the best SED on the performance of the trained networks and also test networks on the galaxy spectra of Coleman et al., which have a lower resolution than the target models. In this way, we conclude that the trained networks take into account all the features of the spectra simultaneously. Using the method, 105 out of 142 galaxies of the sample are classified with high significance. The locus of the classified galaxies in the three graphs of the physical parameters of mass, age, and specific star formation rate appears consistent with the morphological characteristics of the galaxies.
Newman, R A; Emanuel, F W
1991-08-01
This study was designed to investigate the effects of vocal fo on vowel spectral noise level (SNL) and perceived vowel roughness for subjects in high- and low-pitch voice categories. The subjects were 40 adult singers (10 each sopranos, altos, tenors, and basses). Each produced the vowel /a/ in isolation at a comfortable speaking pitch, and at each of seven assigned pitches spaced at whole-tone intervals over a musical octave within his or her singing pitch range. The eight /a/ productions were repeated by each subject on a second test day. The SNL differences between repeated test samples (different days) were not statistically significant for any subject group. For the vowel samples produced at a comfortable pitch, a relatively large SNL was associated with samples phonated by the subjects of each sex who manifested the relatively low singing pitch range. Regarding the vowel samples produced at the assigned-pitch levels, it was found that both vowel SNL and perceived vowel roughness decreased as test-pitch level was raised over a range of one octave. The relationship between vocal pitch and either vowel roughness or SNL approached linearity for each of the four subject groups.
NASA Astrophysics Data System (ADS)
Cao, Jian; Chen, Jing-Bo; Dai, Meng-Xue
2018-01-01
An efficient finite-difference frequency-domain modeling of seismic wave propagation relies on the discrete schemes and appropriate solving methods. The average-derivative optimal scheme for the scalar wave modeling is advantageous in terms of the storage saving for the system of linear equations and the flexibility for arbitrary directional sampling intervals. However, using a LU-decomposition-based direct solver to solve its resulting system of linear equations is very costly for both memory and computational requirements. To address this issue, we consider establishing a multigrid-preconditioned BI-CGSTAB iterative solver fit for the average-derivative optimal scheme. The choice of preconditioning matrix and its corresponding multigrid components is made with the help of Fourier spectral analysis and local mode analysis, respectively, which is important for the convergence. Furthermore, we find that for the computation with unequal directional sampling interval, the anisotropic smoothing in the multigrid precondition may affect the convergence rate of this iterative solver. Successful numerical applications of this iterative solver for the homogenous and heterogeneous models in 2D and 3D are presented where the significant reduction of computer memory and the improvement of computational efficiency are demonstrated by comparison with the direct solver. In the numerical experiments, we also show that the unequal directional sampling interval will weaken the advantage of this multigrid-preconditioned iterative solver in the computing speed or, even worse, could reduce its accuracy in some cases, which implies the need for a reasonable control of directional sampling interval in the discretization.
Spectral of electrocardiographic RR intervals to indicate atrial fibrillation
NASA Astrophysics Data System (ADS)
Nuryani, Nuryani; Satrio Nugroho, Anto
2017-11-01
Atrial fibrillation is a serious heart diseases, which is associated on the risk of death, and thus an early detection of atrial fibrillation is necessary. We have investigated spectral pattern of electrocardiogram in relation to atrial fibrillation. The utilized feature of electrocardiogram is RR interval. RR interval is the time interval between a two-consecutive R peaks. A series of RR intervals in a time segment is converted to a signal with a frequency domain. The frequency components are investigated to find the components which significantly associate to atrial fibrillation. A segment is defined as atrial fibrillation or normal segments by considering a defined number of atrial fibrillation RR in the segment. Using clinical data of 23 patients with atrial fibrillation, we find that the frequency components could be used to indicate atrial fibrillation.
NASA Technical Reports Server (NTRS)
Hoffer, R. M. (Principal Investigator)
1980-01-01
To facilitate comparison between the four different spatial resolution of the NS-001 MSS data sets, a supervised approach was taken in defining training blocks for each of the different cover types. The training fields representing each cover type category were grouped and this group was clustered to determine the individual spectral classes within each cover type category which would effectively characterize the entire test site. Graphs show the variation in spectral response level with respect to distance in the across track dimension for four sampling intervals. Radar digitization procedures were developd. Flight characteristics and parameters for digitization of radar imagery are tabulated. The statement of work for phase 3 was reviewed and modifications were suggested to meet funding reduction.
Coloured Dissolved Organic Matter (CDOM) dynamics in small surface reservoirs in semiarid Brazil
NASA Astrophysics Data System (ADS)
Coelho, Christine; Foerster, Saskia; Heim, Birgit; de Araujo, Jose Carlos
2016-04-01
Coloured Dissolved Organic Matter (CDOM) is one of the major light absorbing constituents in freshwaters. Supplied from degradation of components of the aquatic environment, it consists mainly of humic substances and its concentration is strongly related to primary production, often associated to macrophytes. It plays a central role in several biological and chemical processes affecting the bioavailability of nutrients in aquatic ecosystems. Therefore CDOM can be regarded as a water quality indicator. We used the spectral absorption and spectral slope for understanding CDOM dynamics in surface reservoirs in the Brazilian semiarid region. The analysis was based on water samples collected in three reservoirs in a total of ten sampling locations in the period June 2014 to November 2015 with monthly to bi-monthly intervals totaling 120 samples. The collected water samples were filtered through cellulose acetate membrane filters. Subsequently, spectral absorbance was measured in a Lambda 950 UV-VIS spectrometer in the spectral range 250 to 800 nm using a quartz cuvette with 5 cm optical path. From the absorbance measurement, we obtained CDOM content using the specific absorption coefficient at 440nm as well as spectral slope. The average slope for the entire period for all reservoirs is 0,018, but we found a considerable increase in spectral slope values after the wet period (between February 2014 and June 2014) for the reservoirs São Nicolau and Paus Branco while Marengo reservoir showed only slight variations during this period, but exhibited an increase only in the dry period. Regarding aCDOM(440), the average was equal to 2,55 for Marengo, 5,70 for São Nicolau, and 3,53 for Paus Branco reservoir indicating different characteristics of these reservoirs. We noticed a decrease in the absorption coefficient for São Nicolau and Paus Branco reservoirs at the end of the wet period whereas for Marengo reservoir this value showed a different behavior. Spectral slope and spectral absorption seem consistent and, among other possible factors, its dynamics were affected by high evaporation and low precipitation, typical conditions for semiarid regions in the tropics. The results show also evidence of the hysteresis phenomenon related to humic substance properties. However, it is important to consider also other water quality parameters in order to assess the whole interaction occurring in the reservoirs under eutrophic conditions. This is a first study of the application of spectral absorption and spectral slope of CDOM for small reservoirs in semiarid Brazil providing additional information to the traditional water quality measurements. In the future, we plan to relate the in-situ measurements to satellite imagery to study spatio-temporal water quality dynamics and relate them to land use changes.
Stability across environments of the coffee variety near infrared spectral signature.
Posada, H; Ferrand, M; Davrieux, F; Lashermes, P; Bertrand, B
2009-02-01
Previous study on food plants has shown that near infrared (NIR) spectral methods seem effective for authenticating coffee varieties. We confirm that result, but also show that inter-variety differences are not stable from one harvest to the next. We put forward the hypothesis that the spectral signature is affected by environmental factors. The purpose of this study was to find a way of reducing this environmental variance to increase the method's reliability and to enable practical application in breeding. Spectral collections were obtained from ground green coffee samples from multilocation trials. Two harvests of bean samples from 11 homozygous introgressed lines, and the cv 'Caturra' as the control, supplied from three different sites, were compared. For each site, squared Euclidean distances among the 12 varieties were estimated from the NIR spectra. Matrix correlation coefficients were assessed by the Mantel test. We obtained very good stability (high correlations) for inter-variety differences across the sites when using the two harvests data. If only the most heritable zones of the spectrum were used, there was a marked improvement in the efficiency of the method. This improvement was achieved by treating the spectrum as succession of phenotypic variables, each resulting from an environmental and genetic effect. Heritabilities were calculated with confidence intervals. A near infrared spectroscopy signature, acquired over a set of harvests, can therefore effectively characterize a coffee variety. We indicated how this typical signature can be used in breeding to assist in selection.
Solid laboratory calibration of a nonimaging spectroradiometer.
Schaepman, M E; Dangel, S
2000-07-20
Field-based nonimaging spectroradiometers are often used in vicarious calibration experiments for airborne or spaceborne imaging spectrometers. The calibration uncertainties associated with these ground measurements contribute substantially to the overall modeling error in radiance- or reflectance-based vicarious calibration experiments. Because of limitations in the radiometric stability of compact field spectroradiometers, vicarious calibration experiments are based primarily on reflectance measurements rather than on radiance measurements. To characterize the overall uncertainty of radiance-based approaches and assess the sources of uncertainty, we carried out a full laboratory calibration. This laboratory calibration of a nonimaging spectroradiometer is based on a measurement plan targeted at achieving a =10% uncertainty calibration. The individual calibration steps include characterization of the signal-to-noise ratio, the noise equivalent signal, the dark current, the wavelength calibration, the spectral sampling interval, the nonlinearity, directional and positional effects, the spectral scattering, the field of view, the polarization, the size-of-source effects, and the temperature dependence of a particular instrument. The traceability of the radiance calibration is established to a secondary National Institute of Standards and Technology calibration standard by use of a 95% confidence interval and results in an uncertainty of less than ?7.1% for all spectroradiometer bands.
NASA Astrophysics Data System (ADS)
Senthil Kumar, A.; Keerthi, V.; Manjunath, A. S.; Werff, Harald van der; Meer, Freek van der
2010-08-01
Classification of hyperspectral images has been receiving considerable attention with many new applications reported from commercial and military sectors. Hyperspectral images are composed of a large number of spectral channels, and have the potential to deliver a great deal of information about a remotely sensed scene. However, in addition to high dimensionality, hyperspectral image classification is compounded with a coarse ground pixel size of the sensor for want of adequate sensor signal to noise ratio within a fine spectral passband. This makes multiple ground features jointly occupying a single pixel. Spectral mixture analysis typically begins with pixel classification with spectral matching techniques, followed by the use of spectral unmixing algorithms for estimating endmembers abundance values in the pixel. The spectral matching techniques are analogous to supervised pattern recognition approaches, and try to estimate some similarity between spectral signatures of the pixel and reference target. In this paper, we propose a spectral matching approach by combining two schemes—variable interval spectral average (VISA) method and spectral curve matching (SCM) method. The VISA method helps to detect transient spectral features at different scales of spectral windows, while the SCM method finds a match between these features of the pixel and one of library spectra by least square fitting. Here we also compare the performance of the combined algorithm with other spectral matching techniques using a simulated and the AVIRIS hyperspectral data sets. Our results indicate that the proposed combination technique exhibits a stronger performance over the other methods in the classification of both the pure and mixed class pixels simultaneously.
Nandini, Suresh; Ballal, Suma; Kandaswamy, Deivanayagam
2007-02-01
The prolonged setting time of mineral trioxide aggregate (MTA) is the main disadvantage of this material. This study analyzes the influence of glass-ionomer cement on the setting of MTA using laser Raman spectroscopy (LRS). Forty hollow glass molds were taken in which MTA was placed. In Group I specimens, MTA was layered with glass-ionomer cement after 45 minutes. Similar procedures were done for Groups II and III at 4 hours and 3 days, respectively. No glass ionomer was added in Group IV, which were then considered as control samples. Each sample was scanned at various time intervals. At each time interval, the interface between MTA and glass-ionomer cement was also scanned (excluding Group IV). The spectral analysis proved that placement of glass-ionomer cement over MTA after 45 minutes did not affect its setting reaction and calcium salts may be formed in the interface of these two materials.
Optical properties of base dentin ceramics for all-ceramic restorations.
Shiraishi, Takanobu; Wood, Duncan J; Shinozaki, Nobuya; van Noort, Richard
2011-02-01
The study was conducted to compare the optical parameters of VM7(®) M-shade base dentin ceramics (VITA, Germany) for all ceramic restorations to the chemical composition across the 3D-MASTER(®) shade system. Three disc samples, 13 mm diameter and 1.4 mm thickness, were produced for each M-shade following the manufacturer's instructions. Each disc was ground and polished to a thickness of 1.0 mm. Spectral light transmittance and reflectance data were recorded in the visible spectrum under the standard illuminant D65 and 2° observer at 10 nm intervals by using a computer-controlled spectrophotometer. Opacity, translucency and opalescence parameters were determined for each sample. (1) Spectral transmittance and reflectance in the short-wavelength range systematically decreased with increasing chroma number (M1, M2, M3) when compared within the same value (lightness) group. (2) Spectral transmittance and reflectance decreased systematically across the whole visible spectrum with increasing value group number when compared within the same chroma group. (3) Analysis of relationship between chemical composition and various optical parameters for all the samples showed the significant contribution of ZrO₂ and Y₂O₃ substances to optical properties of the present material. Systematic variations in optical properties of VM7(®) M-shade base dentin ceramics were observed throughout the 3D-MASTER(®) shade system and were suggested to be caused by the fine structure of the sample which can interfere with shorter wavelengths in the visible spectrum. Copyright © 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Nine months in space: effects on human autonomic cardiovascular regulation.
Cooke, W H; Ames JE, I V; Crossman, A A; Cox, J F; Kuusela, T A; Tahvanainen, K U; Moon, L B; Drescher, J; Baisch, F J; Mano, T; Levine, B D; Blomqvist, C G; Eckberg, D L
2000-09-01
We studied three Russian cosmonauts to better understand how long-term exposure to microgravity affects autonomic cardiovascular control. We recorded the electrocardiogram, finger photoplethysmographic pressure, and respiratory flow before, during, and after two 9-mo missions to the Russian space station Mir. Measurements were made during four modes of breathing: 1) uncontrolled spontaneous breathing; 2) stepwise breathing at six different frequencies; 3) fixed-frequency breathing; and 4) random-frequency breathing. R wave-to-R wave (R-R) interval standard deviations decreased in all and respiratory frequency R-R interval spectral power decreased in two cosmonauts in space. Two weeks after the cosmonauts returned to Earth, R-R interval spectral power was decreased, and systolic pressure spectral power was increased in all. The transfer function between systolic pressures and R-R intervals was reduced in-flight, was reduced further the day after landing, and had not returned to preflight levels by 14 days after landing. Our results suggest that long-duration spaceflight reduces vagal-cardiac nerve traffic and decreases vagal baroreflex gain and that these changes may persist as long as 2 wk after return to Earth.
Calibration of the venµs super-spectral camera
NASA Astrophysics Data System (ADS)
Topaz, Jeremy; Sprecher, Tuvia; Tinto, Francesc; Echeto, Pierre; Hagolle, Olivier
2017-11-01
A high-resolution super-spectral camera is being developed by Elbit Systems in Israel for the joint CNES- Israel Space Agency satellite, VENμS (Vegetation and Environment monitoring on a new Micro-Satellite). This camera will have 12 narrow spectral bands in the Visible/NIR region and will give images with 5.3 m resolution from an altitude of 720 km, with an orbit which allows a two-day revisit interval for a number of selected sites distributed over some two-thirds of the earth's surface. The swath width will be 27 km at this altitude. To ensure the high radiometric and geometric accuracy needed to fully exploit such multiple data sampling, careful attention is given in the design to maximize characteristics such as signal-to-noise ratio (SNR), spectral band accuracy, stray light rejection, inter- band pixel-to-pixel registration, etc. For the same reasons, accurate calibration of all the principle characteristics is essential, and this presents some major challenges. The methods planned to achieve the required level of calibration are presented following a brief description of the system design. A fuller description of the system design is given in [2], [3] and [4].
Mosaic-Detector-Based Fluorescence Spectral Imager
NASA Technical Reports Server (NTRS)
Son, Kyung-Ah; Moon, Jeong
2007-01-01
A battery-powered, pen-sized, portable instrument for measuring molecular fluorescence spectra of chemical and biological samples in the field has been proposed. Molecular fluorescence spectroscopy is among the techniques used most frequently in laboratories to analyze compositions of chemical and biological samples. Heretofore, it has been possible to measure fluorescence spectra of molecular species at relative concentrations as low as parts per billion (ppb), with a few nm spectral resolution. The proposed instrument would include a planar array (mosaic) of detectors, onto which a fluorescence spectrum would be spatially mapped. Unlike in the larger laboratory-type molecular fluorescence spectrometers, mapping of wavelengths to spatial positions would be accomplished without use of relatively bulky optical parts. The proposed instrument is expected to be sensitive enough to enable measurement of spectra of chemical species at relative concentrations <1 ppb, with spectral resolution that could be tailored by design to be comparable to a laboratory molecular fluorescence spectrometer. The proposed instrument (see figure) would include a button-cell battery and a laser diode, which would generate the monochromatic ultraviolet light needed to excite fluorescence in a sample. The sample would be held in a cell bounded by far-ultraviolet-transparent quartz or optical glass. The detector array would be, more specifically, a complementary metal oxide/ semiconductor or charge-coupled- device imaging photodetector array, the photodetectors of which would be tailored to respond to light in the wavelength range of the fluorescence spectrum to be measured. The light-input face of the photodetector array would be covered with a matching checkerboard array of multilayer thin film interference filters, such that each pixel in the array would be sensitive only to light in a spectral band narrow enough so as not to overlap significantly with the band of an adjacent pixel. The wavelength interval between adjacent pixels (and, thus, the spectral resolution) would typically be chosen by design to be approximately equal to the width of the total fluorescence wavelength range of interest divided by the number of pixels. The unitary structure comprising the photodetector array overlaid with the matching filter array would be denoted a hyperspectral mosaic detector (HMD) array.
NASA Astrophysics Data System (ADS)
Wright, R.; Lucey, P. G.; Crites, S.; Garbeil, H.; Wood, M.; Pilger, E. J.; Honniball, C.; Gabrieli, A.
2016-12-01
Measurements of reflectance or emittance in tens of narrow, contiguous wavebands, allow for the derivation of laboratory quality spectra remotely, from which the chemical composition and physical properties of targets can be determined. Although spaceborne (e.g. EO-1 Hyperion) hyperspectral data in the 0.4-2.5 micron (VSWIR) region are available, the provision of equivalent data in the log-wave infrared has lagged behind, there being no currently operational high spatial resolution LWIR imaging spectrometer on orbit. This is attributable to two factors. Firstly, earth emits less light than it reflects, reducing the signal available to measure in the TIR, and secondly, instruments designed to measure (and spectrally decompose) this signal are more complex, massive, and expensive than their VSWIR counterparts, largely due to the need to cryogenically cool the detector and optics. However, this measurement gap needs to be filled, as LWIR data provide fundamentally different information than VSWIR measurements. The TIRCIS instrument (Thermal Infra-Red Compact Imaging Spectrometer), developed at the Hawaii Institute of Geophysics and Planetology, uses a Fabry-Perot interferometer, an uncooled microbolometer array, and push-broom scanning to acquire hyperspectral image data in the 8-14 micron spectral range. Radiometric calibration is provided by blackbody targets while spectral calibration is achieved using monochromatic light sources. The instrument has a mass of <15 kg and dimensions of 53 cm × 25 cm × 22 cm, and has been designed to be compatible with integration into a micro-satellite platform. (A precursor to this instrument was launched onboard a 55 kg microsatellite as part of the ORS-4 mission in October 2015). The optical design yields a 120 m ground sample size given an orbit of 500 km. Over the wavelength interval of 7.5 to 14 microns up to 50 spectral samples are possible (the accompanying image shows a quartz spectrum composed of 17 spectral samples). Our performance model indicates signal-to-noise ratios of 400-800:1.
Spectral variability of deciduous leaves depending on the developmental stages and tree condition
NASA Astrophysics Data System (ADS)
Song, Y.; Ryu, Y.
2013-12-01
Foliar spectral characteristics could be the key information in modeling forest ecosystem and the remote sensing of vegetation identification. But it is not easy to determine a typical leaf spectrum of a species in a standardized state. That is because of variables critically influencing on the spectral property of leaves, such as inter- and intra-species features, phenological phase, or biotic and abiotic stress. In this study, we attempted to quantify the spectral variability of leaves depending on species, developmental stages, and the condition of trees. The contribution of these factors to the spectral variation was analyzed at the single leaf level, with a large number of samples from deciduous plants in the urban forested area. First, we collected tens of leaf-samples at every biweekly fieldwork in the growing season, for the selected 5 tree species popular in urban parks; Acer palmatum, Carpinus laxiflora, Prunus yedoensis, Quercus acutissima, and Zelkova serrata. And absorbance, reflectance and transmittance spectra of the leaves were acquired at the short-visible (400-700 nm) to infrared (700-2500 nm) spectral region with 1 nm interval. Seasonality in these leaf-spectra was used to understand the inter-species variation depending on developmental stages. Second, as a benchmark for testing intra-species variability and differences by tree condition, we additionally analyzed the spectral reflectance of 504 ripe leaves from 56 cherry trees (Cerasus × yedoensis) collected in the middle of summer. Last, using ANOVA (analysis of variance) and general linear model, we assessed the influence of our tested variables (i.e., species, developmental stage, and tree condition) on the spectral characteristics and their vegetation indices. As a result, we clarified that the changes in leaf-spectra was apparent across all the tested species during the growing season from May to June, indicating the increasing trend of absorbance in photosynthetically active radiation region (400 to 700 nm; PAR) and reflectance in the near infrared region (700 to 1300 nm; NIR). Inter-species variability still appeared substantial and those inherit spectral characteristics was difficult to be described in a single universal vegetation index. The reflectance values of leaves were significantly differed in good and poor tree condition, which could be the other important consideration in the representative scheme of leaf sampling. More discussions will be present about the effect of species, developmental stage, and tree condition to the leaf-spectra and the published vegetation indices.
Long-term cycles in the history of life: periodic biodiversity in the paleobiology database.
Melott, Adrian L
2008-01-01
Time series analysis of fossil biodiversity of marine invertebrates in the Paleobiology Database (PBDB) shows a significant periodicity at approximately 63 My, in agreement with previous analyses based on the Sepkoski database. I discuss how this result did not appear in a previous analysis of the PBDB. The existence of the 63 My periodicity, despite very different treatment of systematic error in both PBDB and Sepkoski databases strongly argues for consideration of its reality in the fossil record. Cross-spectral analysis of the two datasets finds that a 62 My periodicity coincides in phase by 1.6 My, equivalent to better than the errors in either measurement. Consequently, the two data sets not only contain the same strong periodicity, but its peaks and valleys closely correspond in time. Two other spectral peaks appear in the PBDB analysis, but appear to be artifacts associated with detrending and with the increased interval length. Sampling-standardization procedures implemented by the PBDB collaboration suggest that the signal is not an artifact of sampling bias. Further work should focus on finding the cause of the 62 My periodicity.
NASA Astrophysics Data System (ADS)
Wu, Q.; Du, A. M.; Volwerk, M.; Wang, G. Q.
2016-09-01
A statistical study of the THEMIS FGM and ESA data is performed on turbulence of magnetic field and velocity for 218 selected 12 min intervals in BBFs. The spectral index α in the frequency range of 0.005-0.06 Hz are Gaussian distributions. The peaks indexes of total ion velocity Vi and parallel velocity V‖ are 1.95 and 2.07 nearly the spectral index of intermittent low frequency turbulence with large amplitude. However, most probable α of perpendicular velocity V⊥ is about 1.75. It is a little bigger than 5/3 of Kolmogorov (1941). The peak indexes of total magnetic field BT is 1.70 similar to V⊥. Compression magnetic field B‖ are 1.85 which is smaller than 2 and bigger than 5/3 of Kolmogorov (1941). The most probable spectral index of shear B⊥ is about 1.44 which is close to 3/2 of Kraichnan (1965). Max V⊥ have little effect on the power magnitude of VT and V‖ but is positively correlated to spectral index of V⊥. The spectral power of BT, B‖ and B⊥ increase with max perpendicular velocity but spectral indexes of them are negatively correlated to V⊥. The spectral index and the spectral power of magnetic field over the frequency interval 0.005-0.06 Hz is very different from that over 0.08-1 Hz.
Search for Olivine Spectral Signatures on the Surface of Vesta
NASA Technical Reports Server (NTRS)
Palomba, E.; De Sanctis, M. C.; Ammannito, E.; Capaccioni, F.; Capria, M. T.; Farina, M.; Frigeri, A.; Longobardo, A.; Tosi, F.; Zambon, F.;
2012-01-01
The occurrence of olivines on Vesta were first postulated from traditional petrogenetic models which suggest the formation of olivine as lower crustal cumulates. An indirect confirmation is given by their presence as a minor component in some samples of diogenite meteorites, the harzburgitic diogenites and the dunitic diogenites, and as olivine mineral clasts in howardites. Another indication for this mineral was given by interpretations of groundbased and Hubble Space Telescope observations that suggested the presence of local olivine-bearing units on the surface of Vesta. The VIR instrument onboard the DAWN mission has been mapping Vesta since July 2011. VIR acquired hyperspectral images of Vesta s surface in the wavelength range from 0.25 to 5.1 m during Approach, Survey and High Altitude Mapping (HAMO) orbits that allowed a 2/3 of the entire asteroid surface to be mapped. The VIR operative spectral interval, resolution and coverage is suitable for the detection and mapping of any olivine rich regions that may occur on the Vesta surface. The abundance of olivine in diogenites is typically lower than 10% but some samples richer in olivine are known. However, we do not expect to have extensive exposures of olivine-rich material on Vesta. Moreover, the partial overlap of olivine and pyroxene spectral signatures will make olivine difficult to detect. Different spectral parameters have been used to map olivine on extraterrestrial bodies, and here we discuss the different approaches used, and develop new ones specifically for Vesta. Our new methods are based on combinations of the spectral parameters relative to the 1 and 2 micron bands (the most prominent spectral features of Vesta surface in the visible and the infrared), such as band center locations, band depths, band areas, band area ratios. Before the direct application to the VIR data, the efficiency of each approach is evaluated by means of analysis of laboratory spectra of HED meteorites, pyroxenes, olivines and their mixtures.
Controlled breathing protocols probe human autonomic cardiovascular rhythms
NASA Technical Reports Server (NTRS)
Cooke, W. H.; Cox, J. F.; Diedrich, A. M.; Taylor, J. A.; Beightol, L. A.; Ames, J. E. 4th; Hoag, J. B.; Seidel, H.; Eckberg, D. L.
1998-01-01
The purpose of this study was to determine how breathing protocols requiring varying degrees of control affect cardiovascular dynamics. We measured inspiratory volume, end-tidal CO2, R-R interval, and arterial pressure spectral power in 10 volunteers who followed the following 5 breathing protocols: 1) uncontrolled breathing for 5 min; 2) stepwise frequency breathing (at 0.3, 0.25, 0.2, 0.15, 0.1, and 0.05 Hz for 2 min each); 3) stepwise frequency breathing as above, but with prescribed tidal volumes; 4) random-frequency breathing (approximately 0.5-0.05 Hz) for 6 min; and 5) fixed-frequency breathing (0.25 Hz) for 5 min. During stepwise breathing, R-R interval and arterial pressure spectral power increased as breathing frequency decreased. Control of inspired volume reduced R-R interval spectral power during 0.1 Hz breathing (P < 0.05). Stepwise and random-breathing protocols yielded comparable coherence and transfer functions between respiration and R-R intervals and systolic pressure and R-R intervals. Random- and fixed-frequency breathing reduced end-tidal CO2 modestly (P < 0.05). Our data suggest that stringent tidal volume control attenuates low-frequency R-R interval oscillations and that fixed- and random-rate breathing may decrease CO2 chemoreceptor stimulation. We conclude that autonomic rhythms measured during different breathing protocols have much in common but that a stepwise protocol without stringent control of inspired volume may allow for the most efficient assessment of short-term respiratory-mediated autonomic oscillations.
Spectral Characteristics of Salinized Soils during Microbial Remediation Processes.
Ma, Chuang; Shen, Guang-rong; Zhi, Yue-e; Wang, Zi-jun; Zhu, Yun; Li, Xian-hua
2015-09-01
In this study, the spectral reflectance of saline soils, the associated soil salt content (SSC) and the concentrations of salt ions were measured and analysed by tracing the container microbial remediation experiments for saline soil (main salt is sodium chloride) of Dongying City, Shandong Province. The sensitive spectral reflectance bands of saline soils to SSC, Cl- and Na+ in the process of microbial remediation were analysed. The average-dimension reduction of these bands was conducted by using a combination of correlation coefficient and decision coefficient, and by gradually narrowing the sampling interval method. Results showed that the tendency and magnitude of the average spectral reflectance in all bands of saline soils during the total remediation processes were nearly consistent with SSC and with Cl- coocentration, respectively. The degree of salinity of the soil, including SSC and salt ion concentrations, had a significant positive correlation with the spectral reflectance of all bands, particularly in the near-infrared band. The optimal spectral bands of SSC were 1370 to 1445 nm and 1447 to 1608 nm, whereas the optimal spectral bands of Cl- and Na+ were 1336 to 1461 nm and 1471 to 1561 nm, respectively. The relationship model among SSC, soil salt ion concentrations (Cl- and Na+) and soil spectral reflectance of the corresponding optimal spectral band was established. The largest R2 of relationship model between SSC and the average reflectance of associated optimal band reached to 0.95, and RMSEC and RMSEP were 1.076 and 0.591, respectively. Significant statistical analysis of salt factors and soil reflectance for different microbial remediation processes indicated that the spectral response characteristics and sensitivity of SSC to soil reflectance, which implied the feasibility of high spectrum test on soil microbial remediation monitoring, also provided the basis for quick nondestructive monitoring soil bioremediation process by soil spectral reflectance.
The CO2 absorption continuum by high pressure CRDS in the 1.74 μm window
NASA Astrophysics Data System (ADS)
Mondelain, D.; Campargue, A.; Čermák, P.; Gamache, R. R.; Kassi, S.; Tashkun, S. A.; Tran, H.
2017-12-01
The very weak absorption continuum of CO2 is studied by Cavity Ring Down Spectroscopy in three 20 cm-1 wide spectral intervals near the centre of the 1.74 μm window (5693-5795 cm-1). For each spectral interval, a set of room temperature spectra is recorded at pressures between 0 and 10 bar thanks to a high pressure CRDS spectrometer. The absorption continuum is retrieved after subtraction of the contributions due to Rayleigh scattering and to local lines of CO2 and water (present as an impurity in the sample) from the measured extinction. Due to some deficiencies of the CO2 HITRAN2012 line list, a composite line list had to be built on the basis of the Ames calculated line list with line positions adjusted according to the Carbon Dioxide Spectroscopic Databank and self-broadening and pressure shift coefficients calculated with the Complex Robert Bonamy method. The local line contribution of the CO2 monomer is calculated using this list and a Voigt profile truncated at ±25 cm-1 from the line centre. Line mixing effects were taken into account through the use of the impact and Energy Corrected Sudden approximations. The density dependence of the retrieved continuum absorption was found to be purely quadratic in the low frequency interval below 5710 cm-1 but a small significant linear contribution was required to reproduce the observations above this value. This linear increase is tentatively attributed to the foreign-continuum of water vapor present in CO2 sample with a relative concentration of some tens ppm. The retrieved binary coefficient is observed to vary smoothly with the wavenumber with a minimum value of 6×10-10 cm-1 amagat-2. By gathering the present data with the results reported in Kassi et al. J Quant Spectrosc Radiat Transf 2015;167:97, a recommended set of binary coefficients is provided for the 5700-5950 cm-1 region.
NASA Astrophysics Data System (ADS)
Zappacosta, L.; Comastri, A.; Civano, F.; Puccetti, S.; Fiore, F.; Aird, J.; Del Moro, A.; Lansbury, G. B.; Lanzuisi, G.; Goulding, A.; Mullaney, J. R.; Stern, D.; Ajello, M.; Alexander, D. M.; Ballantyne, D. R.; Bauer, F. E.; Brandt, W. N.; Chen, C.-T. J.; Farrah, D.; Harrison, F. A.; Gandhi, P.; Lanz, L.; Masini, A.; Marchesi, S.; Ricci, C.; Treister, E.
2018-02-01
We discuss the spectral analysis of a sample of 63 active galactic nuclei (AGN) detected above a limiting flux of S(8{--}24 {keV})=7× {10}-14 {erg} {{{s}}}-1 {{cm}}-2 in the multi-tiered NuSTAR extragalactic survey program. The sources span a redshift range z=0{--}2.1 (median < z> =0.58). The spectral analysis is performed over the broad 0.5–24 keV energy range, combining NuSTAR with Chandra and/or XMM-Newton data and employing empirical and physically motivated models. This constitutes the largest sample of AGN selected at > 10 {keV} to be homogeneously spectrally analyzed at these flux levels. We study the distribution of spectral parameters such as photon index, column density ({N}{{H}}), reflection parameter ({\\boldsymbol{R}}), and 10–40 keV luminosity ({L}{{X}}). Heavily obscured ({log}[{N}{{H}}/{{cm}}-2]≥slant 23) and Compton-thick (CT; {log}[{N}{{H}}/{{cm}}-2]≥slant 24) AGN constitute ∼25% (15–17 sources) and ∼2–3% (1–2 sources) of the sample, respectively. The observed {N}{{H}} distribution agrees fairly well with predictions of cosmic X-ray background population-synthesis models (CXBPSM). We estimate the intrinsic fraction of AGN as a function of {N}{{H}}, accounting for the bias against obscured AGN in a flux-selected sample. The fraction of CT AGN relative to {log}[{N}{{H}}/{{cm}}-2]=20{--}24 AGN is poorly constrained, formally in the range 2–56% (90% upper limit of 66%). We derived a fraction (f abs) of obscured AGN ({log}[{N}{{H}}/{{cm}}-2]=22{--}24) as a function of {L}{{X}} in agreement with CXBPSM and previous z< 1 X-ray determinations. Furthermore, f abs at z=0.1{--}0.5 and {log}({L}{{x}}/{erg} {{{s}}}-1)≈ 43.6{--}44.3 agrees with observational measurements/trends obtained over larger redshift intervals. We report a significant anti-correlation of R with {L}{{X}} (confirmed by our companion paper on stacked spectra) with considerable scatter around the median R values.
Post-perihelion photometry of dust grains in the coma of 67P Churyumov-Gerasimenko
NASA Astrophysics Data System (ADS)
Frattin, E.; Cremonese, G.; Simioni, E.; Bertini, I.; Lazzarin, M.; Ott, T.; Drolshagen, E.; La Forgia, F.; Sierks, H.; Barbieri, C.; Lamy, P.; Rodrigo, R.; Koschny, D.; Rickman, H.; Keller, H. U.; Agarwal, J.; A'Hearn, M. F.; Barucci, M. A.; Bertaux, J.-L.; Da Deppo, V.; Davidsson, B.; Debei, S.; De Cecco, M.; Deller, J.; Ferrari, S.; Ferri, F.; Fornasier, S.; Fulle, M.; Gicquel, A.; Groussin, O.; Gutierrez, P. J.; Güttler, C.; Hofmann, M.; Hviid, S. F.; Ip, W.-H.; Jorda, L.; Knollenberg, J.; Kramm, J.-R.; Kührt, E.; Küppers, M.; Lara, L. M.; Lopez Moreno, J. J.; Lucchetti, A.; Marzari, F.; Massironi, M.; Mottola, S.; Naletto, G.; Oklay, N.; Pajola, M.; Penasa, L.; Shi, X.; Thomas, N.; Tubiana, C.; Vincent, J.-B.
2017-07-01
We present a photometric analysis of individual dust grains in the coma of comet 67P/Churyumov-Gerasimenko using OSIRIS images taken from 2015 July to 2016 January. We analysed a sample of 555 taken during 18 d at heliocentric distances ranging between 1.25 and 2.04 au and at nucleocentric distances between 80 and 437 km. An automated method to detect the tracks was specifically developed. The images were taken by OSIRIS NAC in four different filters: Near-IR (882 nm), Orange (649 nm), FarOrange (649 nm) and Blue (480 nm). It was not always possible to recognize all the grains in the four filters, hence we measured the spectral slope in two wavelengths ranges: in the interval [480-649] nm, for 1179 grains, and in the interval [649-882] nm, for 746 grains. We studied the evolution of the two populations' average spectral slopes. The data result scattered around the average value in the range [480-649] nm, while in the [649-882] nm we observe a slight decreasing moving away from the Sun as well as a slight increasing with the nucleocentric distance. A spectrophotometric analysis was performed on a subsample of 339 grains. Three major groups were defined, based on the spectral slope between [535-882] nm: (I) the steep spectra that may be related with organic material, (II) the spectra with an intermediate slope, likely a mixture of silicates and organics and (III) flat spectra that may be associated with a high abundance of water ice.
Variables selection methods in near-infrared spectroscopy.
Xiaobo, Zou; Jiewen, Zhao; Povey, Malcolm J W; Holmes, Mel; Hanpin, Mao
2010-05-14
Near-infrared (NIR) spectroscopy has increasingly been adopted as an analytical tool in various fields, such as the petrochemical, pharmaceutical, environmental, clinical, agricultural, food and biomedical sectors during the past 15 years. A NIR spectrum of a sample is typically measured by modern scanning instruments at hundreds of equally spaced wavelengths. The large number of spectral variables in most data sets encountered in NIR spectral chemometrics often renders the prediction of a dependent variable unreliable. Recently, considerable effort has been directed towards developing and evaluating different procedures that objectively identify variables which contribute useful information and/or eliminate variables containing mostly noise. This review focuses on the variable selection methods in NIR spectroscopy. Selection methods include some classical approaches, such as manual approach (knowledge based selection), "Univariate" and "Sequential" selection methods; sophisticated methods such as successive projections algorithm (SPA) and uninformative variable elimination (UVE), elaborate search-based strategies such as simulated annealing (SA), artificial neural networks (ANN) and genetic algorithms (GAs) and interval base algorithms such as interval partial least squares (iPLS), windows PLS and iterative PLS. Wavelength selection with B-spline, Kalman filtering, Fisher's weights and Bayesian are also mentioned. Finally, the websites of some variable selection software and toolboxes for non-commercial use are given. Copyright 2010 Elsevier B.V. All rights reserved.
Cheng, Shuying; Rajarathnam, D; Meiling, Tan; Garland, Marc
2006-05-01
Thermal emission spectral data sets were collected for a thin solid film (parafilm) and a thin liquid film (isopropanol) on the interval of 298-348 K. The measurements were performed using a conventional Fourier transform infrared (FT-IR) spectrometer with external optical bench and in-house-designed emission cell. Both DTGS and MCT detectors were used. The data sets were analyzed with band-target entropy minimization (BTEM), which is a pure component spectral reconstruction program. Pure component emissivities of the parafilm, isopropanol, and thermal background were all recovered without any a priori information. Furthermore, the emissivities were obtained with increased signal-to-noise ratios, and the signals due to absorbance of thermal radiation by gas-phase moisture and CO2 were significantly reduced. As expected, the MCT results displayed better signal-to-noise ratios than the DTGS results, but the latter results were still rather impressive given the low temperatures used in this study. Comparison is made with spectral reconstruction using the orthogonal projection approach-alternating least squares (OPA-ALS) technique. This contribution introduces the primary equation for emission spectral reconstruction using BTEM and discusses some of the unusual characteristics of thermal emission and their impact on the analysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Teimoorinia, H., E-mail: hteimoo@uvic.ca
2012-12-01
The aim of this work is to combine spectral energy distribution (SED) fitting with artificial neural network techniques to assign spectral characteristics to a sample of galaxies at 0.5 < z < 1. The sample is selected from the spectroscopic campaign of the ESO/GOODS-South field, with 142 sources having photometric data from the GOODS-MUSIC catalog covering bands between {approx}0.4 and 24 {mu}m in 10-13 filters. We use the CIGALE code to fit photometric data to Maraston's synthesis spectra to derive mass, specific star formation rate, and age, as well as the best SED of the galaxies. We use the spectralmore » models presented by Kinney et al. as targets in the wavelength interval {approx}1200-7500 A. Then a series of neural networks are trained, with average performance {approx}90%, to classify the best SED in a supervised manner. We consider the effects of the prominent features of the best SED on the performance of the trained networks and also test networks on the galaxy spectra of Coleman et al., which have a lower resolution than the target models. In this way, we conclude that the trained networks take into account all the features of the spectra simultaneously. Using the method, 105 out of 142 galaxies of the sample are classified with high significance. The locus of the classified galaxies in the three graphs of the physical parameters of mass, age, and specific star formation rate appears consistent with the morphological characteristics of the galaxies.« less
Field spectroscopy sampling strategies for improved measurement of Earth surface reflectance
NASA Astrophysics Data System (ADS)
Mac Arthur, A.; Alonso, L.; Malthus, T. J.; Moreno, J. F.
2013-12-01
Over the last two decades extensive networks of research sites have been established to measure the flux of carbon compounds and water vapour between the Earth's surface and the atmosphere using eddy covariance (EC) techniques. However, contributing Earth surface components cannot be determined and (as the ';footprints' are spatially constrained) these measurements cannot be extrapolated to regional cover using this technique. At many of these EC sites researchers have been integrating spectral measurements with EC and ancillary data to better understand light use efficiency and carbon dioxide flux. These spectroscopic measurements could also be used to assess contributing components and provide support for imaging spectroscopy, from airborne or satellite platforms, which can provide unconstrained spatial cover. Furthermore, there is an increasing interest in ';smart' database and information retrieval systems such as that proposed by EcoSIS and OPTIMISE to store, analyse, QA and merge spectral and biophysical measurements and provide information to end users. However, as Earth surfaces are spectrally heterogeneous and imaging and field spectrometers sample different spatial extents appropriate field sampling strategies require to be adopted. To sample Earth surfaces spectroscopists adopt either single; random; regular grid; transect; or 'swiping' point sampling strategies, although little comparative work has been carried out to determine the most appropriate approach; the work by Goetz (2012) is a limited exception. Mac Arthur et al (2012) demonstrated that, for two full wavelength (400 nm to 2,500 nm) field spectroradiometers, the measurement area sampled is defined by each spectroradiometer/fore optic system's directional response function (DRF) rather than the field-of-view (FOV) specified by instrument manufacturers. Mac Arthur et al (2012) also demonstrated that each reflecting element within the sampled area was not weighted equally in the integrated measurement recorded. There were non-uniformities of spectral response with the spectral ';weighting' per wavelength interval being positionally dependent and unique to each spectroradiometer/fore optic system investigated. However, Mac Arthur et al (2012) did not provide any advice on how to compensate for these systematic errors or advise on appropriate sampling strategies. The work reported here will provide the first systematic study of the effect of field spectroscopy sampling strategies for a range of different Earth surface types. Synthetic Earth surface hyperspectral data cubes for each surface type were generated and convolved with a range of the spectrometer/fore optic system directional response functions generated by Mac Arthur et al 2013, to simulate spectroscopic measurements of Earth surfaces. This has enabled different field sampling strategies to be directly compared and their suitability for each measurement purpose and surface type to be assessed and robust field spectroscopy sampling strategy recommendations to be made. This will be particularly of interest to the carbon and water vapour flux communities and assist the development of sampling strategies for field spectroscopy from rotary-wing Unmanned Aerial Vehicles, which will aid acquiring measurements in the spatial domain, and generally further the use of field spectroscopy for quantitative Earth observation.
VizieR Online Data Catalog: Fermi/GBM GRB time-resolved spectral catalog (Yu+, 2016)
NASA Astrophysics Data System (ADS)
Yu, H.-F.; Preece, R. D.; Greiner, J.; Bhat, P. N.; Bissaldi, E.; Briggs, M. S.; Cleveland, W. H.; Connaughton, V.; Goldstein, A.; von Kienlin; A.; Kouveliotou, C.; Mailyan, B.; Meegan, C. A.; Paciesas, W. S.; Rau, A.; Roberts, O. J.; Veres, P.; Wilson-Hodge, C.; Zhang, B.-B.; van Eerten, H. J.
2016-01-01
Time-resolved spectral analysis results of BEST models: for each spectrum GRB name using the Fermi GBM trigger designation, spectrum number within individual burst, start time Tstart and end time Tstop for the time bin, BEST model, best-fit parameters of the BEST model, value of CSTAT per degrees of freedom, 10keV-1MeV photon and energy flux are given. Ep evolutionary trends: for each burst GRB name, number of spectra with Ep, Spearman's Rank Correlation Coefficients between Ep_ and photon flux and 90%, 95%, and 99% confidence intervals, Spearman's Rank Correlation Coefficients between Ep and energy flux and 90%, 95%, and 99% confidence intervals, Spearman's Rank Correlation Coefficient between Ep and time and 90%, 95%, and 99% confidence intervals, trends as determined by computer for 90%, 95%, and 99% confidence intervals, trends as determined by human eyes are given. (2 data files).
NASA Astrophysics Data System (ADS)
Miranda, M.; Trojzuck, A.; Voss, D.; Gassmann, S.; Zielinski, O.
2016-04-01
FDOM is one of the most important carriers of anthropogenic compounds in natural waters. It can combine with environmental contaminants and polymers to form diverse chemical structures. To this end, here a microfluidic chip was designed for the analysis of these changes in fluorescent dissolved organic matter (FDOM) fingerprints due to thermal treatment and varying time intervals of exposure. Excitation Emission Matrix Spectroscopy (EEMS) approach was utilized to detect and identify the inherent compounds in sampled FDOM. Strong direct correlations were founded, Spearman rank correlation values (ρ = 0.85 at α = 0.1, n = 4) and linear correlation R2 = 0.8359 were noted between thermal treatment pattern 2 and fluorescence intensity of samples. Materials, acrylic based glue and cyclic olefin copolymer (COC) polymer, used to design the microfluidic sensor were determined to possess unique spectral features in the ultraviolet to green spectrum using EEMS. The study therefore provides an insight on methods to identify contaminants in natural waters. This underlines the potential of optical sensors providing measurements at fast intervals, enabling environmental monitoring.
NASA Astrophysics Data System (ADS)
Da Silva, A. C.; Hladil, J.; Chadimová, L.; Slavík, L.; Hilgen, F. J.; Bábek, O.; Dekkers, M. J.
2016-12-01
The Early Devonian geological time scale (base of the Devonian at 418.8 ± 2.9 Myr, Becker et al., 2012) suffers from poor age control, with associated large uncertainties between 2.5 and 4.2 Myr on the stage boundaries. Identifying orbital cycles from sedimentary successions can serve as a very powerful chronometer to test and, where appropriate, improve age models. Here, we focus on the Lochkovian and Pragian, the two lowermost Devonian stages. High-resolution magnetic susceptibility (χin - 5 to 10 cm sampling interval) and gamma ray spectrometry (GRS - 25 to 50 cm sampling interval) records were gathered from two main limestone sections, Požár-CS (118 m, spanning the Lochkov and Praha Formations) and Pod Barrandovem (174 m; Praha Formation), both in the Czech Republic. An additional section (Branžovy, 65 m, Praha Formation) was sampled for GRS (every 50 cm). The χin and GRS records are very similar, so χin variations are driven by variations in the samples' paramagnetic clay mineral content, reflecting changes in detrital input. Therefore, climatic variations are very likely captured in our records. Multiple spectral analysis and statistical techniques such as: Continuous Wavelet Transform, Evolutive Harmonic Analysis, Multi-taper method and Average Spectral Misfit, were used in concert to reach an optimal astronomical interpretation. The Požár-CS section shows distinctly varying sediment accumulation rates. The Lochkovian (essentially equivalent to the Lochkov Formation (Fm.)) is interpreted to include a total of nineteen 405 kyr eccentricity cycles, constraining its duration to 7.7 ± 2.8 Myr. The Praha Fm. includes fourteen 405 kyr eccentricity cycles in the three sampled sections, while the Pragian Stage only includes about four 405 kyr eccentricity cycles, thus exhibiting durations of 5.7 ± 0.6 Myr and 1.7 ± 0.7 Myr respectively. Because the Lochkov Fm. contains an interval with very low sediment accumulation rate and because the Praha Fm. was cross-validated in three different sections, the uncertainty in the duration of the Lochkov Fm. and the Lochkovian is larger than that of the Praha Fm. and Pragian. The new floating time scales for the Lochkovian and Pragian stages have an unprecedented precision, with reduction in the uncertainty by a factor of 1.7 for the Lochkovian and of ∼6 for the Pragian. Furthermore, longer orbital modulation cycles are also identified with periodicities of ∼1000 kyr and 2000-2500 kyr.
Nguyen, Tanya T.; Ashrafi, Ashkan; Thomas, Jennifer D.; Riley, Edward P.; Simmons, Roger W.
2013-01-01
To extend our current understanding of the teratogenic effects of prenatal alcohol exposure on the control of isometric force, the present study investigated the signal characteristics of power spectral density functions resulting from sustained control of isometric force by children with and without heavy prenatal exposure to alcohol. It was predicted that the functions associated with the force signals would be fundamentally different for the two groups. Twenty-five children aged between 7 and 17 years with heavy prenatal alcohol exposure and 21 non-alcohol exposed control children attempted to duplicate a visually represented target force by pressing on a load cell. The level of target force (5 and 20% of maximum voluntary contraction) and the time interval between visual feedback (20ms, 320ms and 740ms) were manipulated. A multivariate spectral estimation method with sinusoidal windows was applied to individual isometric force-time signals. Analysis of the resulting power spectral density functions revealed that the alcohol-exposed children had a lower mean frequency, less spectral variability, greater peak power and a lower frequency at which peak power occurred. Furthermore, mean frequency and spectral variability produced by the alcohol-exposed group remained constant across target load and visual feedback interval, suggesting that these children were limited to making long-time scale corrections to the force signal. In contrast, the control group produced decreased mean frequency and spectral variability as target force and the interval between visual feedback increased, indicating that when feedback was frequently presented these children used the information to make short-time scale adjustments to the ongoing force signal. Knowledge of these differences could facilitate the design of motor rehabilitation exercises that specifically target isometric force control deficits in alcohol-exposed children. PMID:23238099
NASA Astrophysics Data System (ADS)
Trofimov, Vyacheslav A.; Varentsova, Svetlana A.; Krotkus, Arunas; Molis, Gediminas
2010-10-01
The SDA (Spectral Dynamics Analysis) - method (method of THz spectrum dynamics analysis in THz range of frequencies) is used for the detection and identification of substances with similar THz Fourier spectra (such substances are named usually as the simulants) in the two- or three-component medium. This method allows us to obtain the unique 2D THz signature of the substance - the spectrogram- and to analyze the dynamics of many spectral lines of the THz signal, passed through or reflected from substance, by one set of its integral measurements simultaneously; even measurements are made on short-term intervals (less than 20 ps). For long-term intervals (100 ps and more) the SDA method gives an opportunity to define the relaxation time for excited energy levels of molecules. This information gives new opportunity to identify the substance because the relaxation time is different for molecules of different substances. The restoration of the signal by its integral values is made on the base of SVD - Single Value Decomposition - technique. We consider three examples for PTFE mixed with small content of the L-Tartaric Acid and the Sucrose in pellets. A concentration of these substances is about 5%-10%. Our investigations show that the spectrograms and dynamics of spectral lines of THz pulse passed through the pure PTFE differ from the spectrograms of the compound medium containing PTFE and the L-Tartaric Acid or the Sucrose or both these substances together. So, it is possible to detect the presence of a small amount of the additional substances in the sample even their THz Fourier spectra are practically identical. Therefore, the SDA method can be very effective for the defense and security applications and for quality control in pharmaceutical industry. We also show that in the case of substances-simulants the use of auto- and correlation functions has much worse resolvability in a comparison with the SDA method.
Sogani, Julie; Morris, Elizabeth A; Kaplan, Jennifer B; D'Alessio, Donna; Goldman, Debra; Moskowitz, Chaya S; Jochelson, Maxine S
2017-01-01
Purpose To assess the extent of background parenchymal enhancement (BPE) at contrast material-enhanced (CE) spectral mammography and breast magnetic resonance (MR) imaging, to evaluate interreader agreement in BPE assessment, and to examine the relationships between clinical factors and BPE. Materials and Methods This was a retrospective, institutional review board-approved, HIPAA-compliant study. Two hundred seventy-eight women from 25 to 76 years of age with increased breast cancer risk who underwent CE spectral mammography and MR imaging for screening or staging from 2010 through 2014 were included. Three readers independently rated BPE on CE spectral mammographic and MR images with the ordinal scale: minimal, mild, moderate, or marked. To assess pairwise agreement between BPE levels on CE spectral mammographic and MR images and among readers, weighted κ coefficients with quadratic weights were calculated. For overall agreement, mean κ values and bootstrapped 95% confidence intervals were calculated. The univariate and multivariate associations between BPE and clinical factors were examined by using generalized estimating equations separately for CE spectral mammography and MR imaging. Results Most women had minimal or mild BPE at both CE spectral mammography (68%-76%) and MR imaging (69%-76%). Between CE spectral mammography and MR imaging, the intrareader agreement ranged from moderate to substantial (κ = 0.55-0.67). Overall agreement on BPE levels between CE spectral mammography and MR imaging and among readers was substantial (κ = 0.66; 95% confidence interval: 0.61, 0.70). With both modalities, BPE demonstrated significant association with menopausal status, prior breast radiation therapy, hormonal treatment, breast density on CE spectral mammographic images, and amount of fibroglandular tissue on MR images (P < .001 for all). Conclusion There was substantial agreement between readers for BPE detected on CE spectral mammographic and MR images. © RSNA, 2016.
1978-03-01
receiver. 7te rrinzinal caracteristics of such a device are its n.m- sass: srt, r.edir, and lcng term stability. The spectral nuri ty ca "- l .aser is...imperfection of a plastic , inhomogeneous, poorly-understood Earth, then problems begin to arise.The rotation axis of the crust is no longer fixed with...at NRL, the sample was manipulated with cleaned tweezers and placed on fresh, clean aluminum foil; plastic gloves were used also in the-handling of
Contributions of tidal lung inflation to human R-R interval and arterial pressure fluctuations
NASA Technical Reports Server (NTRS)
Koh, J.; Brown, T. E.; Beightol, L. A.; Eckberg, D. L.
1998-01-01
We studied the effects of mechanical lung inflation on respiratory frequency R-R interval and arterial pressure fluctuations in nine healthy young adults undergoing elective orthopedic surgery. We conducted this research to define the contribution of pulmonary and thoracic stretch receptor input to respiratory sinus arrhythmia. We compared fast Fourier transform spectral power during three modes of ventilation: (1) spontaneous, frequency-controlled (0.25 Hz) breathing, (2) intermittent positive pressure ventilation (0.25 Hz, with a tidal volume of 8 ml/kg) and (3) high frequency jet ventilation (5.0 Hz, 2.5 kg/cm2), after sedation and vecuronium paralysis. Mean R-R intervals, arterial pressures and arterial blood gas levels were comparable during all three breathing conditions. Respiratory frequency systolic pressure spectral power was comparable during spontaneous breathing and conventional mechanical ventilation, but was significantly reduced during high frequency jet ventilation (P < 0.05). Respiratory frequency R-R interval spectral power (used as an index of respiratory sinus arrhythmia) declined dramatically with sedation and muscle paralysis (P < 0.05), but was greater during conventional mechanical, than high frequency jet ventilation (P < 0.05). These results suggest that although phasic inputs from pulmonary and thoracic stretch receptors make a statistically significant contribution to respiratory sinus arrhythmia, that contribution is small.
Martian Surface Compositions and Spectral Unit Mapping From the Thermal Emission Imaging System
NASA Astrophysics Data System (ADS)
Bandfield, J. L.; Christensen, P. R.; Rogers, D.
2005-12-01
The Thermal Emission Imaging System (THEMIS) on board the Mars Odyssey spacecraft observes Mars at nine spectral intervals between 6 and 15 microns and at 100 meter spatial sampling. This spectral and spatial resolution allows for mapping of local spectral units and coarse compositional determination of a variety of rock-forming materials such as carbonates, sulfates, and silicates. A number of data processing and atmospheric correction techniques have been developed to ease and speed the interpretation of multispectral THEMIS infrared images. These products and techniques are in the process of being made publicly available via the THEMIS website and were used to produce the results presented here. Spectral variability at kilometer scales in THEMIS data is more common in the southern highlands than in the northern lowlands. Many of the spectral units are associated with a mobile surface layer such as dune fields and mantled dust. However, a number of spectral units appear to be directly tied to the local geologic rock units. These spectral units are commonly associated with crater walls, floors, and ejecta blankets. Other surface compositions are correlated with layered volcanic materials and knobby remnant terrains. Most of the spectral variability observed to date appears to be tied to a variation in silicate mineralogy. Olivine rich units that have been previously reported in Nili Fossae, Ares Valles, and the Valles Marineris region appear to be sparse but common in a number of regions in the southern highlands. Variations in silica content consistent with previously reported global surface units also appear to be present in THEMIS images, allowing for an examination of their local geologic context. Previously reported quartz and feldspar rich exposures in northern Syrtis Major appear more extensive in the region than previously reported. A coherent global and local picture of the mineralogy of the Martian surface is emerging from THEMIS measurements along with other orbital thermal and near infrared spectroscopy measurements from the Mars Express and Mars Global Surveyor spacecraft.
Dobryakov, A L; Kovalenko, S A; Weigel, A; Pérez-Lustres, J L; Lange, J; Müller, A; Ernsting, N P
2010-11-01
A setup for pump/supercontinuum-probe spectroscopy is described which (i) is optimized to cancel fluctuations of the probe light by single-shot referencing, and (ii) extends the probe range into the near-uv (1000-270 nm). Reflective optics allow 50 μm spot size in the sample and upon entry into two separate spectrographs. The correlation γ(same) between sample and reference readings of probe light level at every pixel exceeds 0.99, compared to γ(consec)<0.92 reported for consecutive referencing. Statistical analysis provides the confidence interval of the induced optical density, ΔOD. For demonstration we first examine a dye (Hoechst 33258) bound in the minor groove of double-stranded DNA. A weak 1.1 ps spectral oscillation in the fluorescence region, assigned to DNA breathing, is shown to be significant. A second example concerns the weak vibrational structure around t=0 which reflects stimulated Raman processes. With 1% fluctuations of probe power, baseline noise for a transient absorption spectrum becomes 25 μOD rms in 1 s at 1 kHz, allowing to record resonance Raman spectra of flavine adenine dinucleotide in the S(0) and S(1) state.
The Electric Field and Waves Instruments on the Radiation Belt Storm Probes Mission
NASA Astrophysics Data System (ADS)
Wygant, J. R.; Bonnell, J. W.; Goetz, K.; Ergun, R. E.; Mozer, F. S.; Bale, S. D.; Ludlam, M.; Turin, P.; Harvey, P. R.; Hochmann, R.; Harps, K.; Dalton, G.; McCauley, J.; Rachelson, W.; Gordon, D.; Donakowski, B.; Shultz, C.; Smith, C.; Diaz-Aguado, M.; Fischer, J.; Heavner, S.; Berg, P.; Malsapina, D. M.; Bolton, M. K.; Hudson, M.; Strangeway, R. J.; Baker, D. N.; Li, X.; Albert, J.; Foster, J. C.; Chaston, C. C.; Mann, I.; Donovan, E.; Cully, C. M.; Cattell, C. A.; Krasnoselskikh, V.; Kersten, K.; Brenneman, A.; Tao, J. B.
2013-11-01
The Electric Fields and Waves (EFW) Instruments on the two Radiation Belt Storm Probe (RBSP) spacecraft (recently renamed the Van Allen Probes) are designed to measure three dimensional quasi-static and low frequency electric fields and waves associated with the major mechanisms responsible for the acceleration of energetic charged particles in the inner magnetosphere of the Earth. For this measurement, the instrument uses two pairs of spherical double probe sensors at the ends of orthogonal centripetally deployed booms in the spin plane with tip-to-tip separations of 100 meters. The third component of the electric field is measured by two spherical sensors separated by ˜15 m, deployed at the ends of two stacer booms oppositely directed along the spin axis of the spacecraft. The instrument provides a continuous stream of measurements over the entire orbit of the low frequency electric field vector at 32 samples/s in a survey mode. This survey mode also includes measurements of spacecraft potential to provide information on thermal electron plasma variations and structure. Survey mode spectral information allows the continuous evaluation of the peak value and spectral power in electric, magnetic and density fluctuations from several Hz to 6.5 kHz. On-board cross-spectral data allows the calculation of field-aligned wave Poynting flux along the magnetic field. For higher frequency waveform information, two different programmable burst memories are used with nominal sampling rates of 512 samples/s and 16 k samples/s. The EFW burst modes provide targeted measurements over brief time intervals of 3-d electric fields, 3-d wave magnetic fields (from the EMFISIS magnetic search coil sensors), and spacecraft potential. In the burst modes all six sensor-spacecraft potential measurements are telemetered enabling interferometric timing of small-scale plasma structures. In the first burst mode, the instrument stores all or a substantial fraction of the high frequency measurements in a 32 gigabyte burst memory. The sub-intervals to be downloaded are uplinked by ground command after inspection of instrument survey data and other information available on the ground. The second burst mode involves autonomous storing and playback of data controlled by flight software algorithms, which assess the "highest quality" events on the basis of instrument measurements and information from other instruments available on orbit. The EFW instrument provides 3-d wave electric field signals with a frequency response up to 400 kHz to the EMFISIS instrument for analysis and telemetry (Kletzing et al. Space Sci. Rev. 2013).
Longitudinal change in dysarthria associated with Friedreich ataxia: a potential clinical endpoint.
Rosen, Kristin M; Folker, Joanne E; Vogel, Adam P; Corben, Louise A; Murdoch, Bruce E; Delatycki, Martin B
2012-11-01
CNS functions that show change across short periods of time are particularly useful clinical endpoints for Friedreich ataxia. This study determined whether there is measurable acoustical change in the dysarthria associated with Friedreich ataxia across yearly intervals. A total of 29 participants diagnosed with Friedreich ataxia were recorded across 4 years at yearly intervals. A repeated measures ANOVA was used to determine which acoustic measures differed across time, and pairwise t tests were used to assess the consistency of the change across the time intervals. The relationship between the identified measures with perceptual severity was assessed with stepwise regression. Significant longitudinal change was observed with four measures that relate to the utterance duration and spectral changes in utterances. The spectral measures consistently detected change across time intervals of two or more years. The four measures combined moderately predicted perceptual severity. Together, the results implicate longitudinal change in speaking rate and utterance duration. Changes in speech associated with Friedreich ataxia can be measured across intervals of 2 years and therefore show rich potential for monitoring disease progression and therapy outcomes.
NASA Technical Reports Server (NTRS)
Bigger, J. T. Jr; Steinman, R. C.; Rolnitzky, L. M.; Fleiss, J. L.; Albrecht, P.; Cohen, R. J.
1996-01-01
BACKGROUND. The purposes of the present study were (1) to establish normal values for the regression of log(power) on log(frequency) for, RR-interval fluctuations in healthy middle-aged persons, (2) to determine the effects of myocardial infarction on the regression of log(power) on log(frequency), (3) to determine the effect of cardiac denervation on the regression of log(power) on log(frequency), and (4) to assess the ability of power law regression parameters to predict death after myocardial infarction. METHODS AND RESULTS. We studied three groups: (1) 715 patients with recent myocardial infarction; (2) 274 healthy persons age and sex matched to the infarct sample; and (3) 19 patients with heart transplants. Twenty-four-hour RR-interval power spectra were computed using fast Fourier transforms and log(power) was regressed on log(frequency) between 10(-4) and 10(-2) Hz. There was a power law relation between log(power) and log(frequency). That is, the function described a descending straight line that had a slope of approximately -1 in healthy subjects. For the myocardial infarction group, the regression line for log(power) on log(frequency) was shifted downward and had a steeper negative slope (-1.15). The transplant (denervated) group showed a larger downward shift in the regression line and a much steeper negative slope (-2.08). The correlation between traditional power spectral bands and slope was weak, and that with log(power) at 10(-4) Hz was only moderate. Slope and log(power) at 10(-4) Hz were used to predict mortality and were compared with the predictive value of traditional power spectral bands. Slope and log(power) at 10(-4) Hz were excellent predictors of all-cause mortality or arrhythmic death. To optimize the prediction of death, we calculated a log(power) intercept that was uncorrelated with the slope of the power law regression line. We found that the combination of slope and zero-correlation log(power) was an outstanding predictor, with a relative risk of > 10, and was better than any combination of the traditional power spectral bands. The combination of slope and log(power) at 10(-4) Hz also was an excellent predictor of death after myocardial infarction. CONCLUSIONS. Myocardial infarction or denervation of the heart causes a steeper slope and decreased height of the power law regression relation between log(power) and log(frequency) of RR-interval fluctuations. Individually and, especially, combined, the power law regression parameters are excellent predictors of death of any cause or arrhythmic death and predict these outcomes better than the traditional power spectral bands.
NASA Astrophysics Data System (ADS)
Luna, Aderval S.; Gonzaga, Fabiano B.; da Rocha, Werickson F. C.; Lima, Igor C. A.
2018-01-01
Laser-induced breakdown spectroscopy (LIBS) analysis was carried out on eleven steel samples to quantify the concentrations of chromium, nickel, and manganese. LIBS spectral data were correlated to known concentrations of the samples using different strategies in partial least squares (PLS) regression models. For the PLS analysis, one predictive model was separately generated for each element, while different approaches were used for the selection of variables (VIP: variable importance in projection and iPLS: interval partial least squares) in the PLS model to quantify the contents of the elements. The comparison of the performance of the models showed that there was no significant statistical difference using the Wilcoxon signed rank test. The elliptical joint confidence region (EJCR) did not detect systematic errors in these proposed methodologies for each metal.
Mahmoudabadi, Ebrahim; Karimi, Alireza; Haghnia, Gholam Hosain; Sepehr, Adel
2017-09-11
Digital soil mapping has been introduced as a viable alternative to the traditional mapping methods due to being fast and cost-effective. The objective of the present study was to investigate the capability of the vegetation features and spectral indices as auxiliary variables in digital soil mapping models to predict soil properties. A region with an area of 1225 ha located in Bajgiran rangelands, Khorasan Razavi province, northeastern Iran, was chosen. A total of 137 sampling sites, each containing 3-5 plots with 10-m interval distance along a transect established based on randomized-systematic method, were investigated. In each plot, plant species names and numbers as well as vegetation cover percentage (VCP) were recorded, and finally one composite soil sample was taken from each transect at each site (137 soil samples in total). Terrain attributes were derived from a digital elevation model, different bands and spectral indices were obtained from the Landsat7 ETM+ images, and vegetation features were calculated in the plots, all of which were used as auxiliary variables to predict soil properties using artificial neural network, gene expression programming, and multivariate linear regression models. According to R 2 RMSE and MBE values, artificial neutral network was obtained as the most accurate soil properties prediction function used in scorpan model. Vegetation features and indices were more effective than remotely sensed data and terrain attributes in predicting soil properties including calcium carbonate equivalent, clay, bulk density, total nitrogen, carbon, sand, silt, and saturated moisture capacity. It was also shown that vegetation indices including NDVI, SAVI, MSAVI, SARVI, RDVI, and DVI were more effective in estimating the majority of soil properties compared to separate bands and even some soil spectral indices.
Barbin, Douglas Fernandes; Valous, Nektarios A; Dias, Adriana Passos; Camisa, Jaqueline; Hirooka, Elisa Yoko; Yamashita, Fabio
2015-11-01
There is an increasing interest in the use of polysaccharides and proteins for the production of biodegradable films. Visible and near-infrared (VIS-NIR) spectroscopy is a reliable analytical tool for objective analyses of biological sample attributes. The objective is to investigate the potential of VIS-NIR spectroscopy as a process analytical technology for compositional characterization of biodegradable materials and correlation to their mechanical properties. Biofilms were produced by single-screw extrusion with different combinations of polybutylene adipate-co-terephthalate, whole oat flour, glycerol, magnesium stearate, and citric acid. Spectral data were recorded in the range of 400-2498nm at 2nm intervals. Partial least square regression was used to investigate the correlation between spectral information and mechanical properties. Results show that spectral information is influenced by the major constituent components, as they are clustered according to polybutylene adipate-co-terephthalate content. Results for regression models using the spectral information as predictor of tensile properties achieved satisfactory results, with coefficients of prediction (R(2)C) of 0.83, 0.88 and 0.92 (calibration models) for elongation, tensile strength, and Young's modulus, respectively. Results corroborate the correlation of NIR spectra with tensile properties, showing that NIR spectroscopy has potential as a rapid analytical technology for non-destructive assessment of the mechanical properties of the films. Copyright © 2015 Elsevier B.V. All rights reserved.
Mid-infrared Plasmonic Circular Dichroism Generated by Graphene Nanodisk Assemblies.
Kong, Xiang-Tian; Zhao, Runbo; Wang, Zhiming; Govorov, Alexander O
2017-08-09
It is very interesting to bring plasmonic circular dichroism spectroscopy to the mid-infrared spectral interval, and there are two reasons for this. This spectral interval is very important for thermal bioimaging, and simultaneously, this spectral range includes vibrational lines of many chiral biomolecules. Here we demonstrate that graphene plasmons indeed offer such opportunity. In particular, we show that chiral graphene assemblies consisting of a few graphene nanodisks can generate strong circular dichroism (CD) in the mid-infrared interval. The CD signal is generated due to the plasmon-plasmon coupling between adjacent nanodisks in the specially designed chiral graphene assemblies. Because of the large dimension mismatch between the thickness of a graphene layer and the incoming light's wavelength, three-dimensional configurations with a total height of a few hundred nanometers are necessary to obtain a strong CD signal in the mid-infrared range. The mid-infrared CD strength is mainly governed by the total dimensions (total height and helix scaffold radius) of the graphene nanodisk assembly and by the plasmon-plasmon interaction strength between its constitutive nanodisks. Both positive and negative CD bands can be observed in the graphene assembly array. The frequency interval of the plasmonic CD spectra overlaps with the vibrational modes of some important biomolecules, such as DNA and many different peptides, giving rise to the possibility of enhancing the vibrational optical activity of these molecular species by attaching them to the graphene assemblies. Simultaneously the spectral range of chiral mid-infrared plasmons in our structures appears near the typical wavelength of the human-body thermal radiation, and therefore, our chiral metastructures can be potentially utilized as optical components in thermal imaging devices.
Variability of the Magnetic Field Power Spectrum in the Solar Wind at Electron Scales
NASA Astrophysics Data System (ADS)
Roberts, Owen Wyn; Alexandrova, O.; Kajdič, P.; Turc, L.; Perrone, D.; Escoubet, C. P.; Walsh, A.
2017-12-01
At electron scales, the power spectrum of solar-wind magnetic fluctuations can be highly variable and the dissipation mechanisms of the magnetic energy into the various particle species is under debate. In this paper, we investigate data from the Cluster mission’s STAFF Search Coil magnetometer when the level of turbulence is sufficiently high that the morphology of the power spectrum at electron scales can be investigated. The Cluster spacecraft sample a disturbed interval of plasma where two streams of solar wind interact. Meanwhile, several discontinuities (coherent structures) are seen in the large-scale magnetic field, while at small scales several intermittent bursts of wave activity (whistler waves) are present. Several different morphologies of the power spectrum can be identified: (1) two power laws separated by a break, (2) an exponential cutoff near the Taylor shifted electron scales, and (3) strong spectral knees at the Taylor shifted electron scales. These different morphologies are investigated by using wavelet coherence, showing that, in this interval, a clear break and strong spectral knees are features that are associated with sporadic quasi parallel propagating whistler waves, even for short times. On the other hand, when no signatures of whistler waves at ∼ 0.1{--}0.2{f}{ce} are present, a clear break is difficult to find and the spectrum is often more characteristic of a power law with an exponential cutoff.
NASA Astrophysics Data System (ADS)
Shubin, Vladimir V.; Terekhova, Irina V.; Bolychevtseva, Yulia V.; El-Mohsnawy, Eithar; Rögner, Matthias; Mäntele, Werner; Kopczak, Marta J.; Džafić, Enela
2017-05-01
The performance of solar energy conversion into alternative energy sources in artificial systems highly depends on the thermostability of photosystem I (PSI) complexes Terasaki et al. (2007), Iwuchukwu et al. (2010), Kothe et al. (2013) . To assess the thermostability of PSI complexes from the thermophilic cyanobacterium Thermosynechococcus elongatus heating induced perturbations on the level of secondary structure of the proteins were studied. Changes were monitored by Fourier transform infrared (FT-IR) spectra in the mid-IR region upon slow heating (1 °C per minute) of samples in D2O phosphate buffer (pD 7.4) from 20 °C to 100 °C. These spectra showed distinct changes in the Amide I region of PSI complexes as a function of the rising temperature. Absorbance at the Amide I maximum of PSI monomers (centered around 1653 cm- 1), gradually dropped in two temperature intervals, i.e. 60-75 and 80-90 °C. In contrast, absorbance at the Amide I maximum of PSI trimers (around 1656 cm- 1) dropped only in one temperature interval 80-95 °C. The thermal profile of the spectral shift of α-helices bands in the region 1656-1642 cm- 1 confirms the same two temperature intervals for PSI monomers and only one interval for trimers. Apparently, the observed absorbance changes at the Amide I maximum during heating of PSI monomers and trimers are caused by deformation and unfolding of α-helices. The absence of absorbance changes in the interval of 20-65 °C in PSI trimers is probably caused by a greater stability of protein secondary structure as compared to that in monomers. Upon heating above 80 °C a large part of α-helices both in trimers and monomers converts to unordered and aggregated structures. Spectral changes of PSI trimers and monomers heated up to 100 °C are irreversible due to protein denaturation and non-specific aggregation of complexes leading to new absorption bands at 1618-1620 cm- 1. We propose that monomers shield the denaturation sensitive sides at the monomer/monomer interface within a trimer, making the oligomeric structure more stable against thermal stress.
NASA Technical Reports Server (NTRS)
Vilas, F.; Hiroi, T.; Zolensky, M. E.
1993-01-01
Spectra of primitive asteroids (defined as C, P, and D classes and associated subclasses) were compared to the limited number of spectra of CM2 carbonaceous chondrites. An absorption feature located at 0.7 microns attributed to an Fe(+2) - Fe(+3) charge transfer absorption in iron oxides in phyllosilicates is apparent in some of the CM2 carbonaceous chondrite spectra and many of the asteroid spectra. Sawyer found a correlation between the area of the 0.7 micron feature and the mean semimajor axis of the asteroids. Spectra of a larger sample of carbonaceous chondrites, including 7 CM2 chondrites, covering a spectral interval of 0.30-2.5 microns were recently obtained using the Relab instrument at Brown University. These spectra were compared with spectrophotometric asteroid observations in a separate abstract. Those spectra of CM2 chondrites were isolated into the UV, visible and near-infrared spectral regions in order to compare them with high-quality narrowband reflectance spectra.
Characterization of trabecular bone using the backscattered spectral centroid shift.
Wear, Keith A
2003-04-01
Ultrasonic attenuation in bone in vivo is generally measured using a through-transmission method at the calcaneus. Although attenuation in calcaneus has been demonstrated to be a useful predictor for osteoporotic fracture risk, measurements at other clinically important sites, such as hip and spine, could potentially contain additional useful diagnostic information. Through-transmission measurements may not be feasible at these sites due to complex bone shapes and the increased amount of intervening soft tissue. Centroid shift from the backscattered signal is an index of attenuation slope and has been used previously to characterize soft tissues. In this paper, centroid shift from signals backscattered from 30 trabecular bone samples in vitro were measured. Attenuation slope also was measured using a through-transmission method. The correlation coefficient between centroid shift and attenuation slope was -0.71. The 95% confidence interval was (-0.86, -0.47). These results suggest that the backscattered spectral centroid shift may contain useful diagnostic information potentially applicable to hip and spine.
Constraining Both the Star-Formation History and Metal-Enrichment History of Galaxies
NASA Astrophysics Data System (ADS)
Heap, Sara
2005-07-01
Using 380 stellar spectra from Hubble's Next Generation Spectral Library {NGSL; PI=Michael Gregg; GO 9088, 9786} incorporated in our stellar population synthesis code {Bruzual & Charlot 2003}, we propose to constrain simultaneously the star-formation history and mean age, stellar metallicity and mass of galaxies over a wide redshift interval {z= 0 -2}. The main advantages of the NGSL are the high-quality spectrophotometry {S/N >50} and broad wavelength coverage {2000-10, 000 Ang} of the STIS spectra. The NGSL enables mid-UV as well as optical spectral indices to be used, thereby increasing the redshift interval of their application. It also guarantees consistency in treating low- and high-redshift galaxies, since the same stars are used as spectral templates. To realize the full potential of the NGSL, however, will require significant custom data-processing, calibration, and evaluation of the STIS data.
Atropine unmasks bed-rest effect - A spectral analysis of cardiac interbeat intervals
NASA Technical Reports Server (NTRS)
Goldberger, Ary L.; Goldwater, Danielle; Bhargava, Valmik
1986-01-01
Heart rate spectral data obtained for 10 male subjects between 35-49 years following orthostatic tolerance testing with lower body negative pressure prebed rest and after 7-10 days of bed rest, while on placebo and after intravenous atropine are analyzed. Comparison of the spectral atropine rms for subjects prebed rest and after bed rest reveal a decrease from 63 + or - 24 ms to 40 + or - 23 ms. It is observed that heart rate interval variability for subjects after bed rest and with atropine is reduced; the heart rate at bed rest with atropine is increased from 70.4 + or - 12.4 beats/min prebed rest to 83.7 + or - 18.9 beats/min; and the exercise tolerance time for subjects in the atropine prebed-rest phase (658 + or - 352 s) is higher than the bed-rest phase (505 + or - 252 s). It is noted that bed rest impairs the cardiovascular capacity to adaptively modulate physiological responses, atropine exposes bed-rest deconditioning effects, and spectral analysis is useful for studying the effects of bed-rest deconditioning on cardiac dynamics.
NASA Technical Reports Server (NTRS)
Gottlieb, David; Shu, Chi-Wang
1993-01-01
The investigation of overcoming Gibbs phenomenon was continued, i.e., obtaining exponential accuracy at all points including at the discontinuities themselves, from the knowledge of a spectral partial sum of a discontinuous but piecewise analytic function. It was shown that if we are given the first N expansion coefficients of an L(sub 2) function f(x) in terms of either the trigonometrical polynomials or the Chebyshev or Legendre polynomials, an exponentially convergent approximation to the point values of f(x) in any sub-interval in which it is analytic can be constructed.
Morris, Elizabeth A.; Kaplan, Jennifer B.; D’Alessio, Donna; Goldman, Debra; Moskowitz, Chaya S.
2017-01-01
Purpose To assess the extent of background parenchymal enhancement (BPE) at contrast material–enhanced (CE) spectral mammography and breast magnetic resonance (MR) imaging, to evaluate interreader agreement in BPE assessment, and to examine the relationships between clinical factors and BPE. Materials and Methods This was a retrospective, institutional review board–approved, HIPAA-compliant study. Two hundred seventy-eight women from 25 to 76 years of age with increased breast cancer risk who underwent CE spectral mammography and MR imaging for screening or staging from 2010 through 2014 were included. Three readers independently rated BPE on CE spectral mammographic and MR images with the ordinal scale: minimal, mild, moderate, or marked. To assess pairwise agreement between BPE levels on CE spectral mammographic and MR images and among readers, weighted κ coefficients with quadratic weights were calculated. For overall agreement, mean κ values and bootstrapped 95% confidence intervals were calculated. The univariate and multivariate associations between BPE and clinical factors were examined by using generalized estimating equations separately for CE spectral mammography and MR imaging. Results Most women had minimal or mild BPE at both CE spectral mammography (68%–76%) and MR imaging (69%–76%). Between CE spectral mammography and MR imaging, the intrareader agreement ranged from moderate to substantial (κ = 0.55–0.67). Overall agreement on BPE levels between CE spectral mammography and MR imaging and among readers was substantial (κ = 0.66; 95% confidence interval: 0.61, 0.70). With both modalities, BPE demonstrated significant association with menopausal status, prior breast radiation therapy, hormonal treatment, breast density on CE spectral mammographic images, and amount of fibroglandular tissue on MR images (P < .001 for all). Conclusion There was substantial agreement between readers for BPE detected on CE spectral mammographic and MR images. © RSNA, 2016 PMID:27379544
Integral field spectroscopy of the low-mass companion HD 984 B with the Gemini Planet Imager
Johnson-Groh, Mara; Marois, Christian; De Rosa, Robert J.; ...
2017-03-31
We present new observations of the low-mass companion to HD 984 taken with the Gemini Planet Imager (GPI) as a part of the GPI Exoplanet Survey campaign. Images of HD 984 B were obtained in the J (1.12–1.3 μm) and H (1.50–1.80 μm) bands. Combined with archival epochs from 2012 and 2014, we fit the first orbit to the companion to find an 18 au (70-year) orbit with a 68% confidence interval between 14 and 28 au, an eccentricity of 0.18 with a 68% confidence interval between 0.05 and 0.47, and an inclination of 119° with a 68% confidence interval between 114° and 125°. To address the considerable spectral covariance in both spectra, we present a method of splitting the spectra into low and high frequencies to analyze the spectral structure at different spatial frequencies with the proper spectral noise correlation. Using the split spectra, we compare them to known spectral types using field brown dwarf and low-mass star spectra and find a best-fit match of a field gravity M6.5 ± 1.5 spectral type with a corresponding temperature ofmore » $${2730}_{-180}^{+120}$$ K. Photometry of the companion yields a luminosity of $$\\mathrm{log}({L}_{\\mathrm{bol}}$$/$${L}_{\\odot })=-2.88\\pm 0.07$$ dex with DUSTY models. Mass estimates, again from DUSTY models, find an age-dependent mass of 34 ± 1 to 95 ± 4 M Jup. Lastly, these results are consistent with previous measurements of the object.« less
Baek, Hyun Jae; Shin, JaeWook
2017-08-15
Most of the wrist-worn devices on the market provide a continuous heart rate measurement function using photoplethysmography, but have not yet provided a function to measure the continuous heart rate variability (HRV) using beat-to-beat pulse interval. The reason for such is the difficulty of measuring a continuous pulse interval during movement using a wearable device because of the nature of photoplethysmography, which is susceptible to motion noise. This study investigated the effect of missing heart beat interval data on the HRV analysis in cases where pulse interval cannot be measured because of movement noise. First, we performed simulations by randomly removing data from the RR interval of the electrocardiogram measured from 39 subjects and observed the changes of the relative and normalized errors for the HRV parameters according to the total length of the missing heart beat interval data. Second, we measured the pulse interval from 20 subjects using a wrist-worn device for 24 h and observed the error value for the missing pulse interval data caused by the movement during actual daily life. The experimental results showed that mean NN and RMSSD were the most robust for the missing heart beat interval data among all the parameters in the time and frequency domains. Most of the pulse interval data could not be obtained during daily life. In other words, the sample number was too small for spectral analysis because of the long missing duration. Therefore, the frequency domain parameters often could not be calculated, except for the sleep state with little motion. The errors of the HRV parameters were proportional to the missing data duration in the presence of missing heart beat interval data. Based on the results of this study, the maximum missing duration for acceptable errors for each parameter is recommended for use when the HRV analysis is performed on a wrist-worn device.
Human responses to upright tilt: a window on central autonomic integration
NASA Technical Reports Server (NTRS)
Cooke, W. H.; Hoag, J. B.; Crossman, A. A.; Kuusela, T. A.; Tahvanainen, K. U.; Eckberg, D. L.
1999-01-01
1. We examined interactions between haemodynamic and autonomic neural oscillations during passive upright tilt, to gain better insight into human autonomic regulatory mechanisms. 2. We recorded the electrocardiogram, finger photoplethysmographic arterial pressure, respiration and peroneal nerve muscle sympathetic activity in nine healthy young adults. Subjects breathed in time with a metronome at 12 breaths min-1 (0.2 Hz) for 5 min each, in supine, and 20, 40, 60, 70 and 80 deg head-up positions. We performed fast Fourier transform (and autoregressive) power spectral analyses and integrated low-frequency (0.05-0.15 Hz) and respiratory-frequency (0. 15-0.5 Hz) spectral powers. 3. Integrated areas of muscle sympathetic bursts and their low- and respiratory-frequency spectral powers increased directly and significantly with the tilt angle. The centre frequency of low-frequency sympathetic oscillations was constant before and during tilt. Sympathetic bursts occurred more commonly during expiration than inspiration at low tilt angles, but occurred equally in expiration and inspiration at high tilt angles. 4. Systolic and diastolic pressures and their low- and respiratory-frequency spectral powers increased, and R-R intervals and their respiratory-frequency spectral power decreased progressively with the tilt angle. Low-frequency R-R interval spectral power did not change. 5. The cross-spectral phase angle between systolic pressures and R-R intervals remained constant and consistently negative at the low frequency, but shifted progressively from positive to negative at the respiratory frequency during tilt. The arterial baroreflex modulus, calculated from low-frequency cross-spectra, decreased at high tilt angles. 6. Our results document changes of baroreflex responses during upright tilt, which may reflect leftward movement of subjects on their arterial pressure sympathetic and vagal response relations. The intensity, but not the centre frequency of low-frequency cardiovascular rhythms, is modulated by the level of arterial baroreceptor input. Tilt reduces respiratory gating of sympathetic and vagal motoneurone responsiveness to stimulatory inputs for different reasons; during tilt, sympathetic stimulation increases to a level that overwhelms the respiratory gate, and vagal stimulation decreases to a level below that necessary for maximal respiratory gating to occur.
Human responses to upright tilt: a window on central autonomic integration.
Cooke, W H; Hoag, J B; Crossman, A A; Kuusela, T A; Tahvanainen, K U; Eckberg, D L
1999-06-01
1. We examined interactions between haemodynamic and autonomic neural oscillations during passive upright tilt, to gain better insight into human autonomic regulatory mechanisms. 2. We recorded the electrocardiogram, finger photoplethysmographic arterial pressure, respiration and peroneal nerve muscle sympathetic activity in nine healthy young adults. Subjects breathed in time with a metronome at 12 breaths min-1 (0.2 Hz) for 5 min each, in supine, and 20, 40, 60, 70 and 80 deg head-up positions. We performed fast Fourier transform (and autoregressive) power spectral analyses and integrated low-frequency (0.05-0.15 Hz) and respiratory-frequency (0. 15-0.5 Hz) spectral powers. 3. Integrated areas of muscle sympathetic bursts and their low- and respiratory-frequency spectral powers increased directly and significantly with the tilt angle. The centre frequency of low-frequency sympathetic oscillations was constant before and during tilt. Sympathetic bursts occurred more commonly during expiration than inspiration at low tilt angles, but occurred equally in expiration and inspiration at high tilt angles. 4. Systolic and diastolic pressures and their low- and respiratory-frequency spectral powers increased, and R-R intervals and their respiratory-frequency spectral power decreased progressively with the tilt angle. Low-frequency R-R interval spectral power did not change. 5. The cross-spectral phase angle between systolic pressures and R-R intervals remained constant and consistently negative at the low frequency, but shifted progressively from positive to negative at the respiratory frequency during tilt. The arterial baroreflex modulus, calculated from low-frequency cross-spectra, decreased at high tilt angles. 6. Our results document changes of baroreflex responses during upright tilt, which may reflect leftward movement of subjects on their arterial pressure sympathetic and vagal response relations. The intensity, but not the centre frequency of low-frequency cardiovascular rhythms, is modulated by the level of arterial baroreceptor input. Tilt reduces respiratory gating of sympathetic and vagal motoneurone responsiveness to stimulatory inputs for different reasons; during tilt, sympathetic stimulation increases to a level that overwhelms the respiratory gate, and vagal stimulation decreases to a level below that necessary for maximal respiratory gating to occur.
NASA Astrophysics Data System (ADS)
Machikhin, Alexander; Burmak, Ludmila; Pozhar, Vitold
2018-04-01
The manuscript addresses the advantages and possible applications of acousto-optic image spectral filtration in lowcoherence interferometry. In particular, an effective operation of acousto-optical tunable filters in combination with Michelson-type interferometers is shown. The results of original experiments are presented. It is demonstrated that amplitude and phase spatial distributions of light waves reflected from or transmitted through the object can be fast determined in contactless manner for any spectral intervals with use of the presented techniques.
The Simulation Realization of Pavement Roughness in the Time Domain
NASA Astrophysics Data System (ADS)
XU, H. L.; He, L.; An, D.
2017-10-01
As the needs for the dynamic study on the vehicle-pavement system and the simulated vibration table test, how to simulate the pavement roughness actually is important guarantee for whether calculation and test can reflect the actual situation or not. Using the power spectral density function, the simulation of pavement roughness can be realized by Fourier inverse transform. The main idea of this method was that the spectrum amplitude and random phase were obtained separately according to the power spectrum, and then the simulation of pavement roughness was obtained in the time domain through the Fourier inverse transform (IFFT). In the process, the sampling interval (Δl) was 0.1m, and the sampling points(N) was 4096, which satisfied the accuracy requirements. Using this method, the simulate results of pavement roughness (A~H grades) were obtain in the time domain.
Walker, J W; Campbell, E S; Lupton, C J; Taylor, C A; Waldron, D F; Landau, S Y
2007-02-01
The effects of breed, sex, and age of goats on fecal near-infrared reflectance spectroscopy-predicted percentage juniper in the diet were investigated, as were spectral differences in feces from goats differing in estimated genetic merit for juniper consumption. Eleven goats from each breed, sex, and age combination, representing 2 breeds (Angora and meat-type), 3 sex classifications (female, intact male, and castrated male), and 2 age categories [adult and kid (less than 12 mo of age)] were fed complete, pelleted rations containing 0 or 14% juniper. After 7 d on the same diet, fecal samples were collected for 3 d, and the spectra from the 3 replicate samples were averaged. Fecal samples were assigned to calibration or validation data sets. In a second experiment, Angora and meat goats with high or low estimated genetic merit for juniper consumption were fed the same diet to determine the effect of consumer group on fecal spectra. Feces were scanned in the 1,100- to 2,500-nm range with a scanning reflectance monochromator. Fecal spectra were analyzed for the difference in spectral characteristics and for differences in predicted juniper in the diet using internal and independent calibration equations. Internal calibration had a high precision (R(2) = 0.94), but the precision of independent validations (r(2) = 0.56) was low. Spectral differences were affected by diet, sex, breed, and age (P < 0.04). However, diet was the largest source of variation in spectral differences. Predicted percentage of juniper in the diet also showed that diet was the largest source of variation, accounting for 95% of the variation in predictions from internal calibrations and 51% of the variation in independent validations. Predictions from independent calibrations readily detected differences (P < 0.001) in the percentage of juniper in the 2 diets, and the predicted differences were similar to the actual differences. Predicted juniper in the diet was also affected by sex. Feces from goats from different juniper consumer groups fed a common diet were spectrally different, and the difference may have resulted from a greater intake by high- compared with low-juniper-consuming goats. Fecal near-infrared reflectance spectroscopy predictions of botanical composition of diets should be considered an interval scale of measurement.
On the selection of high-z quasars using LOFAR observations
NASA Astrophysics Data System (ADS)
Retana-Montenegro, Edwin; Röttgering, Huub
2018-03-01
We present a method to identify candidate quasars which combines optical/infrared color selection with radio detections from the Low Frequency ARray (LOFAR) at 150MHz. We apply this {method} in a region of 9 square degrees located in the Boötes field, with a wealth of multi-wavelength data. Our LOFAR imaging in the central region reaches a rms noise of ˜50μJy with a resolution of 5''. This is so deep that we also routinely, `radio-quiet' quasars. We use quasar spectroscopy from the literature to calculate the completeness and efficiency of our selection method. We conduct our analysis in two redshift intervals, 1
Altered skin flowmotion in hypertensive humans
Bruning, R.S.; Kenney, W.L.; Alexander, L.M.
2017-01-01
Essential hypertensive humans exhibit attenuated cutaneous nitric oxide (NO)-dependent vasodilation. Using spectral analysis (fast Fourier transformation) we aimed to characterize the skin flowmotion contained in the laser-Doppler flowmetry recordings during local heating-induced vasodilation before and after concurrent pharmacological inhibition of nitric oxide synthase (NOS) in hypertensive and age-matched normotensive men and women. We hypothesized that hypertensive subjects would have lower total power spectral densities (PSD), specifically in the frequency intervals associated with intrinsic endothelial and neurogenic control of the microvasculature. Furthermore, we hypothesized that NOS inhibition would attenuate the endothelial frequency interval. Laser-Doppler flowmetry recordings during local heating experiments from 18 hypertensive (MAP: 108±2mmHg) and 18 normotensive (MAP: 88±2mmHg) men and women were analyzed. Within site NO-dependent vasodilation was assessed by perfusion of a non-specific NOS inhibitor (NG-nitro-L-arginine methyl ester; L-NAME) through intradermal microdialysis during the heating-induced plateau in skin blood flow. Local heating-induced vasodilation increased total PSD for all frequency intervals (all p<0.001). Hypertensives had a lower total PSD (p=0.03) and absolute neurogenic frequency intervals (p<0.01) compared to the normotensives. When normalized as a percentage of total PSD, hypertensives had reduced neurogenic (p<0.001) and augmented myogenic contributions (p=0.04) to the total spectrum. NOS inhibition decreased total PSD (p<0.001) for both groups, but hypertensives exhibited lower absolute endothelial (p<0.01), neurogenic (p<0.05), and total PSD (p<0.001) frequency intervals compared to normotensives. These data suggest that essential hypertension results in altered neurogenic and NOS-dependent control of skin flowmotion and support the use of spectral analysis as a non-invasive technique to study vasoreactivity. PMID:24418051
NASA Astrophysics Data System (ADS)
Kislov, E. V.; Kulikov, A. A.; Kulikova, A. B.
1989-10-01
Samples of basit-ultrabasit rocks and NiCu ores of the Ioko-Dovyren and Chaya massifs were analysed by SRXFA and a chemical-spectral method. SRXFA perfectly satisfies the quantitative noble-metals analysis of ore-free rocks. Combination of SRXFA and chemical-spectral analysis has good prospects. After analysis of a great number of samples by SRXFA it is necessary to select samples which would show minimal and maximal results for the chemical-spectral method.
Kollarits, Dennis; Wappl, Christian; Ringler, Max
2017-01-30
Acoustic species recognition in anurans depends on spectral and temporal characteristics of the advertisement call. The recognition space of a species is shaped by the likelihood of heterospecific acoustic interference. The dendrobatid frogs Allobates talamancae (Cope, 1875) and Silverstoneia flotator (Dunn, 1931) occur syntopically in south-west Costa Rica. A previous study showed that these two species avoid acoustic interference by spectral stratification. In this study, the role of the temporal call structure in the advertisement call of A. talamancae was analyzed, in particular the internote-interval duration in providing species specific temporal cues. In playback trials, artificial advertisement calls with internote-intervals deviating up to ± 90 % from the population mean internote-interval were broadcast to vocally active territorial males. The phonotactic reactions of the males indicated that, unlike in closely related species, internote-interval duration is not a call property essential for species recognition in A. talamancae . However, temporal call structure may be used for species recognition when the likelihood of heterospecific interference is high. Also, the close-encounter courtship call of male A. talamancae is described.
Influence of Arctic cloud thermodynamic phase on surface shortwave flux
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lubin, D.; Vogelmann, A.
2010-03-15
As part of the Indirect and Semi-Direct Aerosol Campaign (ISDAC) an Analytical Spectral Devices (ASD, Inc.) spectroradiometer was deployed at the Barrow NSA site during April and May of 2008, and in April-October of 2009. This instrument recorded one-minute averages of surface downwelling spectral flux in the wavelength interval 350-2200 nm, thus sampling the two major near infrared windows (1.6 and 2.2 microns) in which the flux is influenced by cloud microphysical properties including thermodynamic phase and effective particle size. Aircraft in situ measurements of cloud properties show mostly mixed-phase clouds over Barrow during the campaign, but with wide variabilitymore » in relative liquid versus ice water content. At fixed total optical depth, this variability in phase composition can yield of order 5-10 Watts per square meter in surface flux variability, with greater cloud attenuation of the surface flux usually occurring under higher ice water content. Thus our data show that changes in cloud phase properties, even within the 'mixed-phase' category, can affect the surface energy balance at the same order of magnitude as greenhouse gas increases. Analysis of this spectral radiometric data provides suggestions for testing new mixed-phase parameterizations in climate models.« less
Infrared spectrometry studies: Spectral digital data acquisition system (1971 version)
NASA Technical Reports Server (NTRS)
Lu, L.; Lyon, R. J. P.
1971-01-01
The construction of the Stanford Spectral Digital Data Acquisition System is described. The objective of the system is to record both the spectral distribution of incoming radiation from the rock samples measured by the spectroradiometer (Exotech Model 10-34 Circular Variable Filter Infrared Spectroradiometer) together with other weather information. This system is designed for both laboratory and field measurement programs. The multichannel inputs (8 channels) of the system are as follows: Ch 1 the Spectro-radiometer, Ch 2 the radiometer (PRT-5), and Ch 3 to Ch 8 for the weather information. The system records data from channel 1 and channel 2 alternately for 48 times, before a fast sweep across the six weather channels, to form a single scan in the scan counter. The operation is illustrated in a block diagram, and the theory of operation is described. The outputs are written on a 7-track magnetic tape with IBM compatible form. The format of the tape and the playback computer programs are included. The micro-pac digital modules and a CIPHER model 70 tape recorder (Cipher Data Products) are used. One of the major characteristics of this system is that it is externally clocked by the spectroradiometer instead of taking data at intervals of various wavelengths by using internal-clocking.
Nematov, Sherzod; Casazza, Anna Paola; Remelli, William; Khuvondikov, Vakhobjon; Santabarbara, Stefano
2017-07-01
The spectral dependence of the irreversible non-photochemical fluorescence quenching associated with photoinhibition in vitro has been comparatively investigated in thylakoid membranes, PSII enriched particles and PSII core complexes isolated from spinach. The analysis of the fluorescence emission spectra of dark-adapted and quenched samples as a function of the detection temperature in the 280-80K interval, indicates that Chlorophyll spectral forms having maximal emission in the 700-702nm and 705-710nm ranges gain relative intensity in concomitance with the establishment of irreversible light-induced quenching, acting thereby as spectroscopic markers. The relative enhancement of the 700-702nm and 705-710nm forms emission could be due either to an increase of their stoichiometric abundance or to their intrinsically low fluorescence quantum yields. These two factors, that can also coexist, need to be promoted by light-induced alterations in chromophore-protein as well as chromophore-chromophore interactions. The bands centred at about 701 and 706nm are also observed in the PSII core complex, suggesting their, at least partial, localisation in proximity to the reaction centre, and the occurrence of light-induced conformational changes in the core subunits. Copyright © 2017 Elsevier B.V. All rights reserved.
Cardiovascular response to acute stress in freely moving rats: time-frequency analysis.
Loncar-Turukalo, Tatjana; Bajic, Dragana; Japundzic-Zigon, Nina
2008-01-01
Spectral analysis of cardiovascular series is an important tool for assessing the features of the autonomic control of the cardiovascular system. In this experiment Wistar rats ecquiped with intraarterial catheter for blood pressure (BP) recording were exposed to stress induced by blowing air. The problem of non stationary data was overcomed applying the Smoothed Pseudo Wigner Villle (SPWV) time-frequency distribution. Spectral analysis was done before stress, during stress, immediately after stress and later in recovery. The spectral indices were calculated for both systolic blood pressure (SBP) and pulse interval (PI) series. The time evolution of spectral indices showed perturbed sympathovagal balance.
NASA Astrophysics Data System (ADS)
Racek, František; Jobánek, Adam; Baláž, Teodor; Krejčí, Jaroslav
2017-10-01
Traditionally spectral reflectance of the material is measured and compared with permitted spectral reflectance boundaries. The boundaries are limited by upper and lower curve of spectral reflectance. The boundaries for unique color has to fulfil the operational requirements as a versatility of utilization through the all year seasons, day and weather condition on one hand and chromatic and spectral matching with background as well as the manufacturability on the other hand. The interval between the boundaries suffers with ambivalent feature. Camouflage pattern producer would be happy to see it much wider, but blending effect into its particular background could be better with narrower tolerance limits. From the point of view of long time user of camouflage pattern battledress, there seems to be another ambivalent feature. Width of the tolerance zone reflecting natural dispersion of spectral reflectance values allows the significant distortions of shape of the spectral curve inside the given boundaries.
SNPP VIIRS Spectral Bands Co-Registration and Spatial Response Characterization
NASA Technical Reports Server (NTRS)
Lin, Guoqing; Tilton, James C.; Wolfe, Robert E.; Tewari, Krishna P.; Nishihama, Masahiro
2013-01-01
The Visible Infrared Imager Radiometer Suite (VIIRS) instrument onboard the Suomi National Polar-orbiting Partnership (SNPP) satellite was launched on 28 October 2011. The VIIRS has 5 imagery spectral bands (I-bands), 16 moderate resolution spectral bands (M-bands) and a panchromatic day/night band (DNB). Performance of the VIIRS spatial response and band-to-band co-registration (BBR) was measured through intensive pre-launch tests. These measurements were made in the non-aggregated zones near the start (or end) of scan for the I-bands and M-bands and for a limited number of aggregation modes for the DNB in order to test requirement compliance. This paper presents results based on a recently re-processed pre-launch test data. Sensor (detector) spatial impulse responses in the scan direction are parameterized in terms of ground dynamic field of view (GDFOV), horizontal spatial resolution (HSR), modulation transfer function (MTF), ensquared energy (EE) and integrated out-of-pixel (IOOP) spatial response. Results are presented for the non-aggregation, 2-sample and 3-sample aggregation zones for the I-bands and M-bands, and for a limited number of aggregation modes for the DNB. On-orbit GDFOVs measured for the 5 I-bands in the scan direction using a straight bridge are also presented. Band-to-band co-registration (BBR) is quantified using the prelaunch measured band-to-band offsets. These offsets may be expressed as fractions of horizontal sampling intervals (HSIs), detector spatial response parameters GDFOV or HSR. BBR bases on HSIs in the non-aggregation, 2-sample and 3-sample aggregation zones are presented. BBR matrices based on scan direction GDFOV and HSR are compared to the BBR matrix based on HSI in the non-aggregation zone. We demonstrate that BBR based on GDFOV is a better representation of footprint overlap and so this definition should be used in BBR requirement specifications. We propose that HSR not be used as the primary image quality indicator, since we show that it is neither an adequate representation of the size of sensor spatial response nor an adequate measure of imaging quality.
Twelve and a Half Years of Observations of Centaurus A with RXTE
NASA Technical Reports Server (NTRS)
Rothschild, R. E.; Markowitz, A.; Rivers, L.; Suchy, S.; Pottschmidt, K.; Kadler, M.; Mueller, C.; Wilms, J.
2011-01-01
The Rossi X-ray Timing Explorer has observed the nearest radio galaxy, Centaurus A, in 13 intervals from 1996 August to 2009 February over the 3 - 200 keV band. Spectra accumulated over the 13 intervals were well described with an absorbed power law and an iron line. Cut-off power laws and Compton reflection from cold matter did not provide a better description. For the 2009 January observation we set a lower limit on the cutoff energy at over 2 MeV. The power spectral density function was generated from RXTE/ASM and PCA data as well as an XMM-Newton long look, and clear evidence for a break at 18(+18/-7) days (68% conf.) was seen. Given Cen A's high black hole mass and very low value of L(sub x)/L(sub Edd), the break was a factor of 17+/-9 times higher than the break frequency predicted by the McHardy and coworkers relation, which was empirically derived for a sample of objects, which are radio-quiet and accreting at relatively high values of L(sub bol)/L(sub Edd). We have interpreted our observations in the context of a clumpy molecular torus. The variability characteristics and the broadband spectral energy distribution, when compared to Seyferts, imply that the bright hard X-ray continuum emission may originate at the base of the jet, yet from behind the absorbing line of sight material, in contrast to what is commonly observed from blazars.
Reconstruction of solar spectral irradiance since the Maunder minimum
NASA Astrophysics Data System (ADS)
Krivova, N. A.; Vieira, L. E. A.; Solanki, S. K.
2010-12-01
Solar irradiance is the main external driver of the Earth's climate. Whereas the total solar irradiance is the main source of energy input into the climate system, solar UV irradiance exerts control over chemical and physical processes in the Earth's upper atmosphere. The time series of accurate irradiance measurements are, however, relatively short and limit the assessment of the solar contribution to the climate change. Here we reconstruct solar total and spectral irradiance in the range 115-160,000 nm since 1610. The evolution of the solar photospheric magnetic flux, which is a central input to the model, is appraised from the historical record of the sunspot number using a simple but consistent physical model. The model predicts an increase of 1.25 W/m2, or about 0.09%, in the 11-year averaged solar total irradiance since the Maunder minimum. Also, irradiance in individual spectral intervals has generally increased during the past four centuries, the magnitude of the trend being higher toward shorter wavelengths. In particular, the 11-year averaged Ly-α irradiance has increased by almost 50%. An exception is the spectral interval between about 1500 and 2500 nm, where irradiance has slightly decreased (by about 0.02%).
Inherent length-scales of periodic solar wind number density structures
NASA Astrophysics Data System (ADS)
Viall, N. M.; Kepko, L.; Spence, H. E.
2008-07-01
We present an analysis of the radial length-scales of periodic solar wind number density structures. We converted 11 years (1995-2005) of solar wind number density data into radial length series segments and Fourier analyzed them to identify all spectral peaks with radial wavelengths between 72 (116) and 900 (900) Mm for slow (fast) wind intervals. Our window length for the spectral analysis was 9072 Mm, approximately equivalent to 7 (4) h of data for the slow (fast) solar wind. We required that spectral peaks pass both an amplitude test and a harmonic F-test at the 95% confidence level simultaneously. From the occurrence distributions of these spectral peaks for slow and fast wind, we find that periodic number density structures occur more often at certain radial length-scales than at others, and are consistently observed within each speed range over most of the 11-year interval. For the slow wind, those length-scales are L ˜ 73, 120, 136, and 180 Mm. For the fast wind, those length-scales are L ˜ 187, 270 and 400 Mm. The results argue for the existence of inherent radial length-scales in the solar wind number density.
Airborne Spectral Measurements of Ocean Anisotropy during CLAMS
NASA Technical Reports Server (NTRS)
Gatebe, C. K.; King, M. D.; Arnold, G. T.; Lau, William K. M. (Technical Monitor)
2002-01-01
The Cloud Absorption Radiometer (CAR) aboard the University of Washington Convair CV-580 research aircraft obtained bidirectional reflectance-distribution function (BRDF) of Atlantic Ocean and Dismal Swamp between July 10 and August 2, 2001. The BRDF measurements (15 in total, 8 uncontaminated by clouds) obtained under a variety of sun angles and wind conditions, will be used to characterize ocean anisotropy in support of Chesapeake Lighthouse and Aircraft Measurements for Satellites (CLAMS) science objectives principally to validate products from NASA's EOS satellites, and to parameterize and validate BRDF models of the ocean. In this paper we present results of BRDF of the Ocean under different sun angles and wind conditions. The CAR is capable of measuring scattered light in fourteen spectral bands. The scan mirror, rotating at 100 rpm, directs the light into a Dall-Kirkham telescope where the beam is split into nine paths. Eight light beams pass through beam splitters, dichroics, and lenses to individual detectors (0.34-1.27 micron), and finally are registered by eight data channels. They are sampled simultaneously and continuously. The ninth beam passes through a spinning filter wheel to an InSb detector cooled by a Stirling cycle cooler. Signals registered by the ninth data channel are selected from among six spectral channels (1.55-2.30 micron). The filter wheel can either cycle through all six spectral bands at a prescribed interval (usually changing filter every fifth scan line), or lock onto any one of the six spectral bands and sample it continuously. To measure the BRF of the surface-atmosphere system, the University of Washington CV-580 had to fly in a circle about 3 km in diameter above the surface for roughly two minutes. Replicated observations (multiple circular orbits) were acquired over selected surfaces so that average BRF smooth out small-scale surface and atmospheric inhomogeneities. At an altitude of 600 m above the targeted surface area and with a 1 degree IFOV, the pixel resolution is about 10 m at nadir and about 270 m at an 80 deg. viewing angle from the CAR.
Effects of noradrenaline on human vagal baroreflexes
NASA Technical Reports Server (NTRS)
Airaksinen, K. E.; Huikuri, H. V.; Huhti, L.; Kuusela, T. A.; Tahvanainen, K. U.; Tulppo, M.; Makikallio, T.; Eckberg, D. L.
2001-01-01
BACKGROUND: Baroreflex sensitivity (BRS) is depressed in conditions associated with high sympathetic nerve activity in proportion to circulating noradrenaline (NA) levels. Despite the prognostic importance of measurements of BRS in patients, there is little information on how high NA levels affect arterial baroreflex function. AIM: To understand better the role of NA in cardiovascular homeostasis. METHODS: We gave incremental intravenous NA infusions (at 50 and 100 ng/kg/min) to 12 healthy young men. We measured RR intervals and photoplethysmographic arterial pressures and estimated BRS with cross-spectral and sequence methods during metronome-guided respiration at 0.25 Hz. RESULTS: The high NA infusion rate significantly increased respiratory-frequency (0.15-0.40 Hz) RR interval spectral power and decreased low-frequency (0.04-0.15 Hz) systolic pressure spectral power compared with baseline levels (P < 0.05 for both). Cross-spectral BRS increased from an average (+/- SD) baseline level of 17.3+/-6.6 to 34.1+/-20.8 ms/mmHg at the high NA infusion rate (P < 0.05). Sequence BRS values did not increase significantly during NA infusions. The percentage of sequences with parallel changes in systolic pressures and RR intervals decreased progressively from a baseline level of 16.0+/-12.9 to 10.1+/-7.4 during the low NA infusion rate and to 6.2+/-6.2% during the high rate (P < 0.05 and 0.01, respectively). CONCLUSIONS: Increases in circulating NA to high physiological levels do not depress BRS but interfere with the close baroreflex-mediated coupling that is usually present between arterial pressure and heart rate.
A biological rationale for musical scales.
Gill, Kamraan Z; Purves, Dale
2009-12-03
Scales are collections of tones that divide octaves into specific intervals used to create music. Since humans can distinguish about 240 different pitches over an octave in the mid-range of hearing, in principle a very large number of tone combinations could have been used for this purpose. Nonetheless, compositions in Western classical, folk and popular music as well as in many other musical traditions are based on a relatively small number of scales that typically comprise only five to seven tones. Why humans employ only a few of the enormous number of possible tone combinations to create music is not known. Here we show that the component intervals of the most widely used scales throughout history and across cultures are those with the greatest overall spectral similarity to a harmonic series. These findings suggest that humans prefer tone combinations that reflect the spectral characteristics of conspecific vocalizations. The analysis also highlights the spectral similarity among the scales used by different cultures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tamura, Ayaka, E-mail: tamura.ayaka.88m@st.kyoto-u.ac.jp; Matsumoto, Ayumu; Nishi, Naoya
We investigate the effects of temporal laser profile on the emission spectra of laser ablation plasma in water. We use short-interval (76 ns) double pulses with different pulse durations of the composing two pulses for the irradiation of underwater target. Narrow atomic spectral lines in emission spectra are obtained by the irradiation, where the two pulses are wide enough to be merged into a single-pulse-like temporal profile, while deformed spectra are obtained when the two pulses are fully separated. The behavior of the atomic spectral lines for the different pulse durations is consistent with that of the temporal profiles of themore » optical emission intensities of the plasma. All these results suggest that continuous excitation of the plasma during the laser irradiation for ∼100 ns is a key to obtain narrow emission spectral lines.« less
A Biological Rationale for Musical Scales
Gill, Kamraan Z.; Purves, Dale
2009-01-01
Scales are collections of tones that divide octaves into specific intervals used to create music. Since humans can distinguish about 240 different pitches over an octave in the mid-range of hearing [1], in principle a very large number of tone combinations could have been used for this purpose. Nonetheless, compositions in Western classical, folk and popular music as well as in many other musical traditions are based on a relatively small number of scales that typically comprise only five to seven tones [2]–[6]. Why humans employ only a few of the enormous number of possible tone combinations to create music is not known. Here we show that the component intervals of the most widely used scales throughout history and across cultures are those with the greatest overall spectral similarity to a harmonic series. These findings suggest that humans prefer tone combinations that reflect the spectral characteristics of conspecific vocalizations. The analysis also highlights the spectral similarity among the scales used by different cultures. PMID:19997506
Tiyip, Tashpolat; Ding, Jianli; Zhang, Dong; Liu, Wei; Wang, Fei; Tashpolat, Nigara
2017-01-01
Effective pretreatment of spectral reflectance is vital to model accuracy in soil parameter estimation. However, the classic integer derivative has some disadvantages, including spectral information loss and the introduction of high-frequency noise. In this paper, the fractional order derivative algorithm was applied to the pretreatment and partial least squares regression (PLSR) was used to assess the clay content of desert soils. Overall, 103 soil samples were collected from the Ebinur Lake basin in the Xinjiang Uighur Autonomous Region of China, and used as data sets for calibration and validation. Following laboratory measurements of spectral reflectance and clay content, the raw spectral reflectance and absorbance data were treated using the fractional derivative order from the 0.0 to the 2.0 order (order interval: 0.2). The ratio of performance to deviation (RPD), determinant coefficients of calibration (Rc2), root mean square errors of calibration (RMSEC), determinant coefficients of prediction (Rp2), and root mean square errors of prediction (RMSEP) were applied to assess the performance of predicting models. The results showed that models built on the fractional derivative order performed better than when using the classic integer derivative. Comparison of the predictive effects of 22 models for estimating clay content, calibrated by PLSR, showed that those models based on the fractional derivative 1.8 order of spectral reflectance (Rc2 = 0.907, RMSEC = 0.425%, Rp2 = 0.916, RMSEP = 0.364%, and RPD = 2.484 ≥ 2.000) and absorbance (Rc2 = 0.888, RMSEC = 0.446%, Rp2 = 0.918, RMSEP = 0.383% and RPD = 2.511 ≥ 2.000) were most effective. Furthermore, they performed well in quantitative estimations of the clay content of soils in the study area. PMID:28934274
Apparatus and system for multivariate spectral analysis
Keenan, Michael R.; Kotula, Paul G.
2003-06-24
An apparatus and system for determining the properties of a sample from measured spectral data collected from the sample by performing a method of multivariate spectral analysis. The method can include: generating a two-dimensional matrix A containing measured spectral data; providing a weighted spectral data matrix D by performing a weighting operation on matrix A; factoring D into the product of two matrices, C and S.sup.T, by performing a constrained alternating least-squares analysis of D=CS.sup.T, where C is a concentration intensity matrix and S is a spectral shapes matrix; unweighting C and S by applying the inverse of the weighting used previously; and determining the properties of the sample by inspecting C and S. This method can be used by a spectrum analyzer to process X-ray spectral data generated by a spectral analysis system that can include a Scanning Electron Microscope (SEM) with an Energy Dispersive Detector and Pulse Height Analyzer.
Cardiac reserve during weightlessness simulation and shuttle flight
NASA Technical Reports Server (NTRS)
Goldberger, A. L.
1985-01-01
Bedrest deconditioning is suspected to reduce cardiac function. However, quantitation of subtle decreases in cardiac reserve may be difficult. Normal subjects show considerable variability in heart rate response, reflected by a relatively broadband interbeat interval power spectrum. We hypothesized that the deconditioning effects of bedrest would induce narrowing of this spectrum, reflecting a reduction in the autonomically-modulated variability in heart rate. Ten aerobically conditioned men (average 35-50 years) underwent orthostatic tolerance testing with lower body negative pressure pre-bedrest and after 10 days of bedrest, while on placebo and after intravenous atropine. Spectra were derived by Fourier analysis of 128 interbeat interval data sets from subjects with sufficient numbers of beats during matched periods of the protocol. Data suggest that atropine unmasks the deconditioning effect of bedrest in athletic men, evidenced by a reduction in interbeat interval spectral power compared with placebo. Spectral analysis offers a new means of quantitating the effects of bedrest deconditioning and autonomic perturbations on cardiac dynamics.
The EPIC-MOS Particle-Induced Background Spectra
NASA Technical Reports Server (NTRS)
Kuntz, K. D.; Sowden, S. L.
2007-01-01
In order to analyse diffuse emission that fills the field of view, one must accurately characterize the instrumental backgrounds. For the XMM-Newton EPIC instrument these backgrounds include a temporally variable "quiescent" component. as well as the strongly variable soft proton contamination. We have characterized the spectral and spatial response of the EPIC detectors to these background components and have developed tools to remove these backgrounds from observations. The "quiescent" component was characterized using a combination of the filter-wheel-closed data and a database of unexposed-region data. The soft proton contamination was characterized by differencing images and spectra taken during flared and flare-free intervals. After application of our modeled backgrounds, the differences between independent observations of the same region of "blank sky" are consistent with the statistical uncertainties except when there is clear spectral evidence of solar wind charge exchange emission. Using a large sample of blank sky data, we show that strong magnetospheric SWCX emission requires elevated solar wind fluxes; observations through the densest part of the magnetosheath are not necessarily strongly contaminated with SWCX emission.
NASA Technical Reports Server (NTRS)
Kruse, Fred A.
1990-01-01
The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), flown aboard the NASA ER-2 aircraft in 1987 and 1989, used four linear arrays and four individual spectrometers to collect data simultaneously from the 224 bands in a scanned 614 pixel-wide swath perpendicular to the aircraft direction. The research had two goals. One was to evaluate the AVIRIS data. The other was to look at the subtle lithological variation at the two test sites to develop a better understanding of the regional geology and surficial processes. The geometric characteristics of the data, adequacy of the spatial resolution, and adequacy of the spectral sampling interval are evaluated. Geologic differences at the test sites were mapped. They included lithological variation caused by primary sedimentary layering, facies variation, and weathering; and subtle mineralogical differences caused by hydrothermal alterations of igneous and sedimentary rocks. The investigation used laboratory, field, and aircraft spectral measurements; known properties of geological materials; digital image processing and spectrum processing techniques; and field geologic data to evaluate the selected characteristics of the AVIRIS data.
Mesoscopic effect of spectral modulation for the light transmitted by a SNOM tip
NASA Astrophysics Data System (ADS)
Rähn, M.; Pärs, M.; Palm, V.; Jaaniso, R.; Hizhnyakov, V.
2010-06-01
The effect of a tapered metal-coated optical fiber terminated by a sub-wavelength aperture (SWA) on the spectrum of the transmitted light is investigated experimentally. Under certain conditions a remarkable spectral modulation of the transmitted light can be observed. This effect is of a mesoscopic origin, occurring only for a certain interval of SWA diameters. One can conclude that a noticeable modulation appears when the number of the transmitted fiber modes is small but exceeds unity, thus indicating the presence of a phase shift between different modes. To discern between two possible sources of such phase shift, the fiber length dependence of the output spectrum has been studied. According to the results obtained for the used sample of 200 nm SNOM tip, the observed phase shift is mostly caused rather by the inherent modal dispersion of the multimode fiber than by the mode-dependent light slowdown in the tapered region close to SWA due to the coupling to surface plasmons of the metal coating. The SWA acts here mainly as an effective mode filter.
Copernicus observations of the N v resonance doublet in 53 early-type stars
NASA Technical Reports Server (NTRS)
Abbott, D. C.; Bohlin, R. C.; Savage, B. D.
1982-01-01
UV spectra in the wavelength interval 1170-1270 A are presented for 53 early-type stars ranging in spectral type from O6.5 V to B2.5 IV. The sample includes four Wolf-Rayet stars, seven known Oe-Be stars, and six galactic halo OB stars. A qualitative analysis of the stellar N v doublet reveals that: (1) N v is present in all stars hotter and more luminous than type B0 for the main sequence, B1 for giants, and B2 for supergiants; (2) shell components of N v and an unidentified absorption feature at 1230 A are present in about half of the stars; (3) the column density of N v is well correlated with bolometric luminosity over the spectral range O6 to B2; and (4) the ratio of emission to absorption equivalent width is a factor of 2 smaller in the main sequence stars than in supergiants, which suggests that the wind structure changes as a star evolves. For several stars, this ratio is too small to be explained by traditional wind models.
Method of multivariate spectral analysis
Keenan, Michael R.; Kotula, Paul G.
2004-01-06
A method of determining the properties of a sample from measured spectral data collected from the sample by performing a multivariate spectral analysis. The method can include: generating a two-dimensional matrix A containing measured spectral data; providing a weighted spectral data matrix D by performing a weighting operation on matrix A; factoring D into the product of two matrices, C and S.sup.T, by performing a constrained alternating least-squares analysis of D=CS.sup.T, where C is a concentration intensity matrix and S is a spectral shapes matrix; unweighting C and S by applying the inverse of the weighting used previously; and determining the properties of the sample by inspecting C and S. This method can be used to analyze X-ray spectral data generated by operating a Scanning Electron Microscope (SEM) with an attached Energy Dispersive Spectrometer (EDS).
Laser-induced fluorescence fiber optic probe measurement of oil dilution by fuel
Parks, II, James E [Knoxville, TN; Partridge, Jr., William P [Oak Ridge, TN
2010-11-23
Apparatus for detecting fuel in oil includes an excitation light source in optical communication with an oil sample for exposing the oil sample to excitation light in order to excite the oil sample from a non-excited state to an excited state and a spectrally selective device in optical communication with the oil sample for detecting light emitted from the oil sample as the oil sample returns from the excited state to a non-excited state to produce spectral indicia that can be analyzed to determine the presence of fuel in the oil sample. A method of detecting fuel in oil includes the steps of exposing a oil sample to excitation light in order to excite the oil sample from a non-excited state to an excited state, as the oil sample returns from the excited state to a non-excited state, detecting light emitted from the oil sample to produce spectral indicia; and analyzing the spectral indicia to determine the presence of fuel in the oil sample.
VizieR Online Data Catalog: Low-resolution near-infrared stellar spectra from CIBER (Kim+, 2017)
NASA Astrophysics Data System (ADS)
Kim, M. G.; Lee, H. M.; Arai, T.; Bock, J.; Cooray, A.; Jeong, W.-S.; Kim, S. J.; Korngut, P.; Lanz, A.; Lee, D. H.; Lee, M. G.; Matsumoto, T.; Matsuura, S.; Nam, U. W.; Onishi, Y.; Shirahata, M.; Smidt, J.; Tsumura, K.; Yamamura, I.; Zemcov, M.
2017-06-01
We present flux-calibrated near-infrared spectra of 105 stars from 0.8{<=}λ{<=}1.8μm with spectral resolution 15{<=}λ/Δλ{<=}30 over the range. The Low-Resolution Spectrometer (LRS) is one of the four optical instruments of the Cosmic Infrared Background Experiment (CIBER) payload; the others are a narrowband spectrometer and two wide-field imagers. The LRS is a prism-dispersed spectrometer with five rectangular 5.35°*2.8' slits imaging a 5.8°*5.8° field of view. The detector has 256*256 pixels at a pixel scale of 1.36'*1.36'. CIBER has flown four times (2009 February, 2010 July, 2012 March, and 2013 June) with apogees and total exposure times of over 325km and ~240s, respectively, in the first three flights and of 550km and 335s in the final, non-recovered flight. Due to spurious signal contamination from thermal emission from the shock-heated rocket skin, we do not use the first flight data in this work. The star spectral types are determined by fitting known spectral templates to the measured LRS spectra. We use the Infrared Telescope Facility (IRTF) and Pickles 1998 (Cat. J/PASP/110/863) templates for the SED fitting. The SpeX instrument installed on the IRTF observed stars using a medium-resolution spectrograph (R=2000). The template library contains spectra for 210 cool stars (F to M type) with wavelength coverage from 0.8 to 2.5μm (Cushing 2005ApJ...623.1115C; Rayner 2009ApJS..185..289R). The Pickles library is a synthetic spectral library that combines spectral data from various observations to achieve wavelength coverage from the UV (0.115μm) to the near-infrared (2.5μm). It contains 131 spectral templates for all star types (i.e., O to M type) with a uniform sampling interval of 5Å. (6 data files).
Limb Viewing Hyper Spectral Imager (LiVHySI) for airglow measurements onboard YOUTHSAT-1
NASA Astrophysics Data System (ADS)
Bisht, R. S.; Hait, A. K.; Babu, P. N.; Sarkar, S. S.; Benerji, A.; Biswas, A.; Saji, A. K.; Samudraiah, D. R. M.; Kirankumar, A. S.; Pant, T. K.; Parimalarangan, T.
2014-08-01
The Limb Viewing Hyper Spectral Imager (LiVHySI) is one of the Indian payloads onboard YOUTHSAT (inclination 98.73°, apogee 817 km) launched in April, 2011. The Hyper-spectral imager has been operated in Earth’s limb viewing mode to measure airglow emissions in the spectral range 550-900 nm, from terrestrial upper atmosphere (i.e. 80 km altitude and above) with a line-of-sight range of about 3200 km. The altitude coverage is about 500 km with command selectable lowest altitude. This imaging spectrometer employs a Linearly Variable Filter (LVF) to generate the spectrum and an Active Pixel Sensor (APS) area array of 256 × 512 pixels, placed in close proximity of the LVF as detector. The spectral sampling is done at 1.06 nm interval. The optics used is an eight element f/2 telecentric lens system with 80 mm effective focal length. The detector is aligned with respect to the LVF such that its 512 pixel dimension covers the spectral range. The radiometric sensitivity of the imager is about 20 Rayleigh at noise floor through the signal integration for 10 s at wavelength 630 nm. The imager is being operated during the eclipsed portion of satellite orbits. The integration in the time/spatial domain could be chosen depending upon the season, solar and geomagnetic activity and/or specific target area. This paper primarily aims at describing LiVHySI, its in-orbit operations, quality, potential of the data and its first observations. The images reveal the thermospheric airglow at 630 nm to be the most prominent. These first LiVHySI observations carried out on the night of 21st April, 2011 are presented here, while the variability exhibited by the thermospheric nightglow at O(1D) 630 nm has been described in detail.
The method of trend analysis of parameters time series of gas-turbine engine state
NASA Astrophysics Data System (ADS)
Hvozdeva, I.; Myrhorod, V.; Derenh, Y.
2017-10-01
This research substantiates an approach to interval estimation of time series trend component. The well-known methods of spectral and trend analysis are used for multidimensional data arrays. The interval estimation of trend component is proposed for the time series whose autocorrelation matrix possesses a prevailing eigenvalue. The properties of time series autocorrelation matrix are identified.
Extended Task Space Control for Robotic Manipulators
NASA Technical Reports Server (NTRS)
Backes, Paul G. (Inventor); Long, Mark K. (Inventor)
1996-01-01
The invention is a method of operating a robot in successive sampling intervals to perform a task, the robot having joints and joint actuators with actuator control loops, by decomposing the task into behavior forces, accelerations, velocities and positions of plural behaviors to be exhibited by the robot simultaneously, computing actuator accelerations of the joint actuators for the current sampling interval from both behavior forces, accelerations velocities and positions of the current sampling interval and actuator velocities and positions of the previous sampling interval, computing actuator velocities and positions of the joint actuators for the current sampling interval from the actuator velocities and positions of the previous sampling interval, and, finally, controlling the actuators in accordance with the actuator accelerations, velocities and positions of the current sampling interval. The actuator accelerations, velocities and positions of the current sampling interval are stored for use during the next sampling interval.
Rapid microscopy measurement of very large spectral images.
Lindner, Moshe; Shotan, Zav; Garini, Yuval
2016-05-02
The spectral content of a sample provides important information that cannot be detected by the human eye or by using an ordinary RGB camera. The spectrum is typically a fingerprint of the chemical compound, its environmental conditions, phase and geometry. Thus measuring the spectrum at each point of a sample is important for a large range of applications from art preservation through forensics to pathological analysis of a tissue section. To date, however, there is no system that can measure the spectral image of a large sample in a reasonable time. Here we present a novel method for scanning very large spectral images of microscopy samples even if they cannot be viewed in a single field of view of the camera. The system is based on capturing information while the sample is being scanned continuously 'on the fly'. Spectral separation implements Fourier spectroscopy by using an interferometer mounted along the optical axis. High spectral resolution of ~5 nm at 500 nm could be achieved with a diffraction-limited spatial resolution. The acquisition time is fairly high and takes 6-8 minutes for a sample size of 10mm x 10mm measured under a bright-field microscope using a 20X magnification.
Anisotropy in the Microwave Sky at 90 GHz: Results from Python III
NASA Astrophysics Data System (ADS)
Platt, S. R.; Kovac, J.; Dragovan, M.; Peterson, J. B.; Ruhl, J. E.
1997-01-01
The third year of observations with the Python microwave background experiment densely samples a 5.5d × 22° region of sky that includes the fields measured during the first 2 years of observations with this instrument. The sky is sampled in two multipole bands centered at l ~ 87 and l ~ 170. These two data sets are analyzed to place limits on fluctuations in the microwave sky at 90 GHz. Interpreting the observed fluctuations as anisotropy in the cosmic microwave background, we find flat-band power estimates of δTl ≡ [l(l + 1)Cl/(2π)]1/2 = 60+15-13 μK at l = 87+18-38 and δTl = 66+17-16 μK at l = 170+69-50. Combining the entire 3 year set of Python observations, we find that the angular power spectrum of fluctuations has a spectral index m = 0.16+.20-.18 and an amplitude δTle = 63+15-14 μK at le = 139+99-34 for the functional form δTl = δTle(l/le)m. The stated uncertainties in the amplitudes and spectral index represent 1 σ confidence intervals in the likelihood added in quadrature with a 20% calibration uncertainty and an estimate of the effects of a +/-0.05d uncertainty in the measured beamwidths. The limits of l are determined from the half-maximum points of the window functions.
Marchisio, Andrea; Minella, Marco; Maurino, Valter; Minero, Claudio; Vione, Davide
2015-04-15
Chromophoric dissolved organic matter (CDOM) in surface waters is a photochemical source of several transient species such as CDOM triplet states ((3)CDOM*), singlet oxygen ((1)O2) and the hydroxyl radical (OH). By irradiation of lake water samples, it is shown here that the quantum yields for the formation of these transients by CDOM vary depending on the irradiation wavelength range, in the order UVB > UVA > blue. A possible explanation is that radiation at longer wavelengths is preferentially absorbed by the larger CDOM fractions, which show lesser photoactivity compared to smaller CDOM moieties. The quantum yield variations in different spectral ranges were definitely more marked for (3)CDOM* and OH compared to (1)O2. The decrease of the quantum yields with increasing wavelength has important implications for the photochemistry of surface waters, because long-wavelength radiation penetrates deeper in water columns compared to short-wavelength radiation. The average steady-state concentrations of the transients ((3)CDOM*, (1)O2 and OH) were modelled in water columns of different depths, based on the experimentally determined wavelength trends of the formation quantum yields. Important differences were found between such modelling results and those obtained in a wavelength-independent quantum yield scenario. Copyright © 2015 Elsevier Ltd. All rights reserved.
A seismic coherency method using spectral amplitudes
NASA Astrophysics Data System (ADS)
Sui, Jing-Kun; Zheng, Xiao-Dong; Li, Yan-Dong
2015-09-01
Seismic coherence is used to detect discontinuities in underground media. However, strata with steeply dipping structures often produce false low coherence estimates and thus incorrect discontinuity characterization results. It is important to eliminate or reduce the effect of dipping on coherence estimates. To solve this problem, time-domain dip scanning is typically used to improve estimation of coherence in areas with steeply dipping structures. However, the accuracy of the time-domain estimation of dip is limited by the sampling interval. In contrast, the spectrum amplitude is not affected by the time delays in adjacent seismic traces caused by dipping structures. We propose a coherency algorithm that uses the spectral amplitudes of seismic traces within a predefined analysis window to construct the covariance matrix. The coherency estimates with the proposed algorithm is defined as the ratio between the dominant eigenvalue and the sum of all eigenvalues of the constructed covariance matrix. Thus, we eliminate the effect of dipping structures on coherency estimates. In addition, because different frequency bands of spectral amplitudes are used to estimate coherency, the proposed algorithm has multiscale features. Low frequencies are effective for characterizing large-scale faults, whereas high frequencies are better in characterizing small-scale faults. Application to synthetic and real seismic data show that the proposed algorithm can eliminate the effect of dip and produce better coherence estimates than conventional coherency algorithms in areas with steeply dipping structures.
Effect of non-Poisson samples on turbulence spectra from laser velocimetry
NASA Technical Reports Server (NTRS)
Sree, Dave; Kjelgaard, Scott O.; Sellers, William L., III
1994-01-01
Spectral analysis of laser velocimetry (LV) data plays an important role in characterizing a turbulent flow and in estimating the associated turbulence scales, which can be helpful in validating theoretical and numerical turbulence models. The determination of turbulence scales is critically dependent on the accuracy of the spectral estimates. Spectral estimations from 'individual realization' laser velocimetry data are typically based on the assumption of a Poisson sampling process. What this Note has demonstrated is that the sampling distribution must be considered before spectral estimates are used to infer turbulence scales.
Design framework for a spectral mask for a plenoptic camera
NASA Astrophysics Data System (ADS)
Berkner, Kathrin; Shroff, Sapna A.
2012-01-01
Plenoptic cameras are designed to capture different combinations of light rays from a scene, sampling its lightfield. Such camera designs capturing directional ray information enable applications such as digital refocusing, rotation, or depth estimation. Only few address capturing spectral information of the scene. It has been demonstrated that by modifying a plenoptic camera with a filter array containing different spectral filters inserted in the pupil plane of the main lens, sampling of the spectral dimension of the plenoptic function is performed. As a result, the plenoptic camera is turned into a single-snapshot multispectral imaging system that trades-off spatial with spectral information captured with a single sensor. Little work has been performed so far on analyzing diffraction effects and aberrations of the optical system on the performance of the spectral imager. In this paper we demonstrate simulation of a spectrally-coded plenoptic camera optical system via wave propagation analysis, evaluate quality of the spectral measurements captured at the detector plane, and demonstrate opportunities for optimization of the spectral mask for a few sample applications.
Kim, Mooeung; Chung, Hoeil
2013-03-07
The use of selectivity-enhanced Raman spectra of lube base oil (LBO) samples achieved by the spectral collection under frozen conditions at low temperatures was effective for improving accuracy for the determination of the kinematic viscosity at 40 °C (KV@40). A collection of Raman spectra from samples cooled around -160 °C provided the most accurate measurement of KV@40. Components of the LBO samples were mainly long-chain hydrocarbons with molecular structures that were deformable when these were frozen, and the different structural deformabilities of the components enhanced spectral selectivity among the samples. To study the structural variation of components according to the change of sample temperature from cryogenic to ambient condition, n-heptadecane and pristane (2,6,10,14-tetramethylpentadecane) were selected as representative components of LBO samples, and their temperature-induced spectral features as well as the corresponding spectral loadings were investigated. A two-dimensional (2D) correlation analysis was also employed to explain the origin for the improved accuracy. The asynchronous 2D correlation pattern was simplest at the optimal temperature, indicating the occurrence of distinct and selective spectral variations, which enabled the variation of KV@40 of LBO samples to be more accurately assessed.
TWELVE AND A HALF YEARS OF OBSERVATIONS OF CENTAURUS A WITH THE ROSSI X-RAY TIMING EXPLORER
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rothschild, R. E.; Markowitz, A.; Rivers, E.
2011-05-20
The Rossi X-ray Timing Explorer (RXTE) has observed the nearest radio galaxy, Centaurus A (Cen A), in 13 intervals from 1996 August to 2009 February over the 3-200 keV band. Spectra accumulated over the 13 intervals were well described with an absorbed power law and an iron line. Cutoff power laws and Compton reflection from cold matter did not provide a better description. For the 2009 January observation, we set a lower limit on the cutoff energy at over 2 MeV. The power spectral density function was generated from RXTE/All Sky Monitor and Proportional Counter Array data as well asmore » an XMM-Newton long look, and clear evidence for a break at 18{sup +18}{sub -7} days (68% conf.) was seen. Given Cen A's high black hole mass and very low value of L{sub X}/L{sub Edd}, the break was a factor of 17{sup +36}{sub -13} times higher than the break frequency predicted by the McHardy et al. relation, which was empirically derived for a sample of objects, which are radio-quiet and accreting at relatively high values of L{sub bol}/L{sub Edd}. We have interpreted our observations in the context of a clumpy molecular torus. The variability characteristics and the broadband spectral energy distribution, when compared to Seyferts, imply that the bright hard X-ray continuum emission may originate at the base of the jet, yet from behind the absorbing line-of-sight material, in contrast to what is commonly observed from blazars.« less
NASA Astrophysics Data System (ADS)
Genova, Ts; Borisova, E.; Penkov, N.; Vladimirov, B.; Zhelyazkova, A.; Avramov, L.
2016-06-01
We report the development of an improved fluorescence technique for cancer diagnostics in the gastrointestinal tract. We investigate the fluorescence of ex vivo colorectal (cancerous and healthy) tissue samples using excitation-emission matrix (EEM) and synchronous fluorescence spectroscopy (SFS) steady-state approaches. The obtained results are processed for revealing characteristic fluorescence spectral features with a valuable diagnostic meaning. The main tissue fluorophores, contributing to the observed fluorescence, are tyrosine, tryptophan, NADH, FAD, collagen and elastin. Based on the results of the Mann-Whitney test as useful parameters for differentiation of gastrointestinal cancer from normal mucosa, we suggest using excitation wavelengths in the range 300 - 360 nm for fluorescence spectroscopy and wavelengths intervals of 60 nm and 90 nm for SFS.
USGS Digital Spectral Library splib05a
Clark, Roger N.; Swayze, Gregg A.; Wise, Richard K.; Livo, Eric; Hoefen, Todd M.; Kokaly, Raymond F.; Sutley, Steve J.
2003-01-01
We have assembled a digital reflectance spectral library of spectra that covers wavelengths from the ultraviolet to near-infrared along with sample documentation. The library includes samples of minerals, rocks, soils, physically constructed as well as mathematically computed mixtures, vegetation, microorganisms, and man-made materials. The samples and spectra collected were assembled for the purpose of using spectral features for the remote detection of these and similar materials.
Wang, Qingcui; Bao, Ming; Chen, Lihan
2014-01-01
Previous studies using auditory sequences with rapid repetition of tones revealed that spatiotemporal cues and spectral cues are important cues used to fuse or segregate sound streams. However, the perceptual grouping was partially driven by the cognitive processing of the periodicity cues of the long sequence. Here, we investigate whether perceptual groupings (spatiotemporal grouping vs. frequency grouping) could also be applicable to short auditory sequences, where auditory perceptual organization is mainly subserved by lower levels of perceptual processing. To find the answer to that question, we conducted two experiments using an auditory Ternus display. The display was composed of three speakers (A, B and C), with each speaker consecutively emitting one sound consisting of two frames (AB and BC). Experiment 1 manipulated both spatial and temporal factors. We implemented three 'within-frame intervals' (WFIs, or intervals between A and B, and between B and C), seven 'inter-frame intervals' (IFIs, or intervals between AB and BC) and two different speaker layouts (inter-distance of speakers: near or far). Experiment 2 manipulated the differentiations of frequencies between two auditory frames, in addition to the spatiotemporal cues as in Experiment 1. Listeners were required to make two alternative forced choices (2AFC) to report the perception of a given Ternus display: element motion (auditory apparent motion from sound A to B to C) or group motion (auditory apparent motion from sound 'AB' to 'BC'). The results indicate that the perceptual grouping of short auditory sequences (materialized by the perceptual decisions of the auditory Ternus display) was modulated by temporal and spectral cues, with the latter contributing more to segregating auditory events. Spatial layout plays a less role in perceptual organization. These results could be accounted for by the 'peripheral channeling' theory.
A Long-Term Dissipation of the EUV He ii (30.4 nm) Segmentation in Full-Disk Solar Images
NASA Astrophysics Data System (ADS)
Didkovsky, Leonid
2018-06-01
Some quiet-Sun days observed by the Atmospheric Imaging Assembly (AIA) on-board the Solar Dynamics Observatory (SDO) during the time interval in 2010 - 2017 were used to continue our previous analyses reported by Didkovsky and Gurman ( Solar Phys. 289, 153, 2014a) and Didkovsky, Wieman, and Korogodina ( Solar Phys. 292, 32, 2017). The analysis consists of determining and comparing spatial spectral ratios (spectral densities over some time interval) from spatial (segmentation-cell length) power spectra. The ratios were compared using modeled compatible spatial frequencies for spectra from the Extreme ultraviolet Imaging Telescope (EIT) on-board the Solar and Heliospheric Observatory (SOHO) and from AIA images. With the new AIA data added to the EIT data we analyzed previously, the whole time interval from 1996 to 2017 reported here is approximately the length of two "standard" solar cycles (SC). The spectral ratios of segmentation-cell dimension structures show a significant and steady increase with no detected indication of SC-related returns to the values that characterize the SC minima. This increase in spatial power at high spatial frequencies is interpreted as a dissipation of medium-size EUV network structures to smaller-size structures in the transition region. Each of the latest ratio changes for 2010 through 2017 spectra calculated for a number of consecutive short-term intervals has been converted into monthly mean ratio (MMR) changes. The MMR values demonstrate variable sign and magnitudes, thus confirming the solar nature of the changes. These changes do not follow a "typical" trend of instrumental degradation or a long-term activity profile from the He ii (30.4 nm) irradiance measured by the Extreme ultraviolet Spectrophotometer (ESP) either. The ESP is a channel of the Extreme ultraviolet Variability Experiment (EVE) on-board SDO.
NASA Astrophysics Data System (ADS)
Shan, Jiajia; Wang, Xue; Zhou, Hao; Han, Shuqing; Riza, Dimas Firmanda Al; Kondo, Naoshi
2018-04-01
Synchronous fluorescence spectra, combined with multivariate analysis were used to predict flavonoids content in green tea rapidly and nondestructively. This paper presented a new and efficient spectral intervals selection method called clustering based partial least square (CL-PLS), which selected informative wavelengths by combining clustering concept and partial least square (PLS) methods to improve models’ performance by synchronous fluorescence spectra. The fluorescence spectra of tea samples were obtained and k-means and kohonen-self organizing map clustering algorithms were carried out to cluster full spectra into several clusters, and sub-PLS regression model was developed on each cluster. Finally, CL-PLS models consisting of gradually selected clusters were built. Correlation coefficient (R) was used to evaluate the effect on prediction performance of PLS models. In addition, variable influence on projection partial least square (VIP-PLS), selectivity ratio partial least square (SR-PLS), interval partial least square (iPLS) models and full spectra PLS model were investigated and the results were compared. The results showed that CL-PLS presented the best result for flavonoids prediction using synchronous fluorescence spectra.
Shan, Jiajia; Wang, Xue; Zhou, Hao; Han, Shuqing; Riza, Dimas Firmanda Al; Kondo, Naoshi
2018-03-13
Synchronous fluorescence spectra, combined with multivariate analysis were used to predict flavonoids content in green tea rapidly and nondestructively. This paper presented a new and efficient spectral intervals selection method called clustering based partial least square (CL-PLS), which selected informative wavelengths by combining clustering concept and partial least square (PLS) methods to improve models' performance by synchronous fluorescence spectra. The fluorescence spectra of tea samples were obtained and k-means and kohonen-self organizing map clustering algorithms were carried out to cluster full spectra into several clusters, and sub-PLS regression model was developed on each cluster. Finally, CL-PLS models consisting of gradually selected clusters were built. Correlation coefficient (R) was used to evaluate the effect on prediction performance of PLS models. In addition, variable influence on projection partial least square (VIP-PLS), selectivity ratio partial least square (SR-PLS), interval partial least square (iPLS) models and full spectra PLS model were investigated and the results were compared. The results showed that CL-PLS presented the best result for flavonoids prediction using synchronous fluorescence spectra.
Adaptive detection of noise signal according to Neumann-Pearson criterion
NASA Astrophysics Data System (ADS)
Padiryakov, Y. A.
1985-03-01
Optimum detection according to the Neumann-Pearson criterion is considered in the case of a random Gaussian noise signal, stationary during measurement, and a stationary random Gaussian background interference. Detection is based on two samples, their statistics characterized by estimates of their spectral densities, it being a priori known that sample A from the signal channel is either the sum of signal and interference or interference alone and sample B from the reference interference channel is an interference with the same spectral density as that of the interference in sample A for both hypotheses. The probability of correct detection is maximized on the average, first in the 2N-dimensional space of signal spectral density and interference spectral density readings, by fixing the probability of false alarm at each point so as to stabilize it at a constant level against variation of the interference spectral density. Deterministic decision rules are established. The algorithm is then reduced to equivalent detection in the N-dimensional space of the ratio of sample A readings to sample B readings.
Anisotropic Behaviour of Magnetic Power Spectra in Solar Wind Turbulence.
NASA Astrophysics Data System (ADS)
Banerjee, S.; Saur, J.; Gerick, F.; von Papen, M.
2017-12-01
Introduction:High altitude fast solar wind turbulence (SWT) shows different spectral properties as a function of the angle between the flow direction and the scale dependent mean magnetic field (Horbury et al., PRL, 2008). The average magnetic power contained in the near perpendicular direction (80º-90º) was found to be approximately 5 times larger than the average power in the parallel direction (0º- 10º). In addition, the parallel power spectra was found to give a steeper (-2) power law than the perpendicular power spectral density (PSD) which followed a near Kolmogorov slope (-5/3). Similar anisotropic behaviour has also been observed (Chen et al., MNRAS, 2011) for slow solar wind (SSW), but using a different method exploiting multi-spacecraft data of Cluster. Purpose:In the current study, using Ulysses data, we investigate (i) the anisotropic behaviour of near ecliptic slow solar wind using the same methodology (described below) as that of Horbury et al. (2008) and (ii) the dependence of the anisotropic behaviour of SWT as a function of the heliospheric latitude.Method:We apply the wavelet method to calculate the turbulent power spectra of the magnetic field fluctuations parallel and perpendicular to the local mean magnetic field (LMF). According to Horbury et al., LMF for a given scale (or size) is obtained using an envelope of the envelope of that size. Results:(i) SSW intervals always show near -5/3 perpendicular spectra. Unlike the fast solar wind (FSW) intervals, for SSW, we often find intervals where power parallel to the mean field is not observed. For a few intervals with sufficient power in parallel direction, slow wind turbulence also exhibit -2 parallel spectra similar to FSW.(ii) The behaviours of parallel and perpendicular power spectra are found to be independent of the heliospheric latitude. Conclusion:In the current study we do not find significant influence of the heliospheric latitude on the spectral slopes of parallel and perpendicular magnetic spectra. This indicates that the spectral anisotropy in parallel and perpendicular direction is governed by intrinsic properties of SWT.
USDA-ARS?s Scientific Manuscript database
Six methods were compared with respect to spectral fingerprinting of a well-characterized series of broccoli samples. Spectral fingerprints were acquired for finely-powdered solid samples using Fourier transform-infrared (IR) and Fourier transform-near infrared (NIR) spectrometry and for aqueous met...
Weld defect identification in friction stir welding using power spectral density
NASA Astrophysics Data System (ADS)
Das, Bipul; Pal, Sukhomay; Bag, Swarup
2018-04-01
Power spectral density estimates are powerful in extraction of useful information retained in signal. In the current research work classical periodogram and Welch periodogram algorithms are used for the estimation of power spectral density for vertical force signal and transverse force signal acquired during friction stir welding process. The estimated spectral densities reveal notable insight in identification of defects in friction stir welded samples. It was observed that higher spectral density against each process signals is a key indication in identifying the presence of possible internal defects in the welded samples. The developed methodology can offer preliminary information regarding presence of internal defects in friction stir welded samples can be best accepted as first level of safeguard in monitoring the friction stir welding process.
Robust and transferable quantification of NMR spectral quality using IROC analysis
NASA Astrophysics Data System (ADS)
Zambrello, Matthew A.; Maciejewski, Mark W.; Schuyler, Adam D.; Weatherby, Gerard; Hoch, Jeffrey C.
2017-12-01
Non-Fourier methods are increasingly utilized in NMR spectroscopy because of their ability to handle nonuniformly-sampled data. However, non-Fourier methods present unique challenges due to their nonlinearity, which can produce nonrandom noise and render conventional metrics for spectral quality such as signal-to-noise ratio unreliable. The lack of robust and transferable metrics (i.e. applicable to methods exhibiting different nonlinearities) has hampered comparison of non-Fourier methods and nonuniform sampling schemes, preventing the identification of best practices. We describe a novel method, in situ receiver operating characteristic analysis (IROC), for characterizing spectral quality based on the Receiver Operating Characteristic curve. IROC utilizes synthetic signals added to empirical data as "ground truth", and provides several robust scalar-valued metrics for spectral quality. This approach avoids problems posed by nonlinear spectral estimates, and provides a versatile quantitative means of characterizing many aspects of spectral quality. We demonstrate applications to parameter optimization in Fourier and non-Fourier spectral estimation, critical comparison of different methods for spectrum analysis, and optimization of nonuniform sampling schemes. The approach will accelerate the discovery of optimal approaches to nonuniform sampling experiment design and non-Fourier spectrum analysis for multidimensional NMR.
Integrated fluorescence analysis system
Buican, Tudor N.; Yoshida, Thomas M.
1992-01-01
An integrated fluorescence analysis system enables a component part of a sample to be virtually sorted within a sample volume after a spectrum of the component part has been identified from a fluorescence spectrum of the entire sample in a flow cytometer. Birefringent optics enables the entire spectrum to be resolved into a set of numbers representing the intensity of spectral components of the spectrum. One or more spectral components are selected to program a scanning laser microscope, preferably a confocal microscope, whereby the spectrum from individual pixels or voxels in the sample can be compared. Individual pixels or voxels containing the selected spectral components are identified and an image may be formed to show the morphology of the sample with respect to only those components having the selected spectral components. There is no need for any physical sorting of the sample components to obtain the morphological information.
Information content of IRIS spectra. [from Nimbus 4 satellite
NASA Technical Reports Server (NTRS)
Price, J. C.
1974-01-01
Spectra from the satellite instrument IRIS (infra red interferometer spectrometer) were examined to find the number of independent variables needed to describe these broadband high spectral resolution data. The radiated power in the atmospheric window from 771 to 981/cm was the first parameter chosen for fitting observed spectra. At succeeding levels of analysis the residual variability (observed spectrum - best fit spectrum) in an ensemble of observations was partioned into spectral eigenvectors. The eigenvector describing the largest fraction of this variability was examined for a strong spectral signature; the power in the corresponding spectral band was then used as the next fitting parameter. The measured power in nine spectral intervals, when inserted in the spectral fitting functions, was adequate to describe most spectra to within the noise level of IRIS. Considerations of relative signal strength and scales of atmospheric variability suggest a combination sounder (multichannel-broad field of view) scanner (window channel-small field of view) as an efficient observing instrument.
Properties of Spectral Shapes of Whistler-Mode Emissions
NASA Astrophysics Data System (ADS)
Macusova, E.; Santolik, O.; Pickett, J. S.; Gurnett, D. A.; Cornilleau-Wehrlin, N.
2014-12-01
Whistler-mode emissions play an important role in wave-particle interactions occurring in the radiation belt region. Whistler mode chorus emissions consist of discrete wave packets which exhibit different spectral shapes. Rising tones (events with positive value of the frequency sweep rate) are frequently observed. Other categories of chorus spectral shapes, such as falling tones, hooks, broadband patterns, are also known. Whistler-mode emissions can additionally occur as hiss or combinations of hiss with discrete patterns. In this study, we have analyzed more than 11 years of high-time resolution measurements provided by the Wideband Data (WBD) instrument onboard four Cluster spacecraft to identify different spectral shapes of whistler mode emissions. We determine the distribution of individual groups of chorus spectral shapes in the Earth's magnetosphere and the effect of the different geomagnetic conditions on their occurrence. We focus on average polarization and propagation properties of the different types of spectral shapes, obtained during visually identified time intervals from multicomponent measurements of the STAFF-SA instrument recorded with a time resolution of 4 seconds.
Information content in Iris spectra. [Infrared Interferometer Spectrometer of Nimbus 4 satellite
NASA Technical Reports Server (NTRS)
Price, J. C.
1975-01-01
Spectra from the satellite instrument Iris (infrared interferometer spectrometer) were examined to find the number of independent variables needed to describe the broad-band high-resolution spectral data. The radiated power in the atmospheric window from 771 to 981 per cm was the first parameter chosen for fitting observed spectra. At succeeding levels of analysis, the residual variability (observed spectrum minus best-fit spectrum) in an ensemble of observations was partitioned into spectral eigenvectors. The eigenvector describing the largest fraction of this variability was examined for a strong spectral signature; the power in the corresponding spectral band was then used as the next fitting parameter. The measured power in nine spectral intervals, when it was inserted in the spectral-fitting functions, was adequate to describe most spectra to within the noise level of Iris. Considerations of relative signal strength and scales of atmospheric variability suggest a combination sounder (multichannel, broad field of view) scanner (window channel, small field of view) as an efficient observing instrument.
Spectral filtering for plant production
DOE Office of Scientific and Technical Information (OSTI.GOV)
Young, R.E.; McMahon, M.J.; Rajapakse, N.C.
1994-12-31
Research to date suggests that spectral filtering can be an effective alternative to chemical growth regulators for altering plant development. If properly implemented, it can be nonchemical and environmentally friendly. The aqueous CuSO{sub 4}, and CuCl{sub 2} solutions in channelled plastic panels have been shown to be effective filters, but they can be highly toxic if the solutions contact plants. Some studies suggest that spectral filtration limited to short EOD intervals can also alter plant development. Future research should be directed toward confirmation of the influence of spectral filters and exposure times on a broader range of plant species andmore » cultivars. Efforts should also be made to identify non-noxious alternatives to aqueous copper solutions and/or to incorporate these chemicals permanently into plastic films and panels that can be used in greenhouse construction. It would also be informative to study the impacts of spectral filters on insect and microbal populations in plant growth facilities. The economic impacts of spectral filtering techniques should be assessed for each delivery methodology.« less
Steimer, Andreas; Schindler, Kaspar
2015-01-01
Oscillations between high and low values of the membrane potential (UP and DOWN states respectively) are an ubiquitous feature of cortical neurons during slow wave sleep and anesthesia. Nevertheless, a surprisingly small number of quantitative studies have been conducted only that deal with this phenomenon's implications for computation. Here we present a novel theory that explains on a detailed mathematical level the computational benefits of UP states. The theory is based on random sampling by means of interspike intervals (ISIs) of the exponential integrate and fire (EIF) model neuron, such that each spike is considered a sample, whose analog value corresponds to the spike's preceding ISI. As we show, the EIF's exponential sodium current, that kicks in when balancing a noisy membrane potential around values close to the firing threshold, leads to a particularly simple, approximative relationship between the neuron's ISI distribution and input current. Approximation quality depends on the frequency spectrum of the current and is improved upon increasing the voltage baseline towards threshold. Thus, the conceptually simpler leaky integrate and fire neuron that is missing such an additional current boost performs consistently worse than the EIF and does not improve when voltage baseline is increased. For the EIF in contrast, the presented mechanism is particularly effective in the high-conductance regime, which is a hallmark feature of UP-states. Our theoretical results are confirmed by accompanying simulations, which were conducted for input currents of varying spectral composition. Moreover, we provide analytical estimations of the range of ISI distributions the EIF neuron can sample from at a given approximation level. Such samples may be considered by any algorithmic procedure that is based on random sampling, such as Markov Chain Monte Carlo or message-passing methods. Finally, we explain how spike-based random sampling relates to existing computational theories about UP states during slow wave sleep and present possible extensions of the model in the context of spike-frequency adaptation.
Mukhopadhyay, Pranab K; Gupta, Pradeep K; Singh, Amarjeet; Sharma, Sunil K; Bindra, Kushvinder S; Oak, Shrikant M
2014-05-01
A multimode interference filter with narrow transmission bandwidth and large self-imaging wavelength interval is constructed and implemented in an ytterbium doped fiber laser in all-fiber format for broad wavelength tunability as well as narrow spectral width of the output beam. The peak transmission wavelength of the multimode interference filter was tuned with the help of a standard in-fiber polarization controller. With this simple mechanism more than 30 nm (1038 nm-1070 nm) tuning range is demonstrated. The spectral width of the output beam from the laser was measured to be 0.05 nm.
NASA Astrophysics Data System (ADS)
Mukhopadhyay, Pranab K.; Gupta, Pradeep K.; Singh, Amarjeet; Sharma, Sunil K.; Bindra, Kushvinder S.; Oak, Shrikant M.
2014-05-01
A multimode interference filter with narrow transmission bandwidth and large self-imaging wavelength interval is constructed and implemented in an ytterbium doped fiber laser in all-fiber format for broad wavelength tunability as well as narrow spectral width of the output beam. The peak transmission wavelength of the multimode interference filter was tuned with the help of a standard in-fiber polarization controller. With this simple mechanism more than 30 nm (1038 nm-1070 nm) tuning range is demonstrated. The spectral width of the output beam from the laser was measured to be 0.05 nm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mukhopadhyay, Pranab K., E-mail: pkm@rrcat.gov.in; Gupta, Pradeep K.; Singh, Amarjeet
2014-05-15
A multimode interference filter with narrow transmission bandwidth and large self-imaging wavelength interval is constructed and implemented in an ytterbium doped fiber laser in all-fiber format for broad wavelength tunability as well as narrow spectral width of the output beam. The peak transmission wavelength of the multimode interference filter was tuned with the help of a standard in-fiber polarization controller. With this simple mechanism more than 30 nm (1038 nm–1070 nm) tuning range is demonstrated. The spectral width of the output beam from the laser was measured to be 0.05 nm.
Airborne Spectral Measurements of Surface-Atmosphere Anisotropy for Skukuza and Mongu Sites
NASA Technical Reports Server (NTRS)
Gatebe, C. K.; King, Michael D.; Arnold, G. T.; Li, J. Y.
2001-01-01
The Cloud Absorption Radiometer (CAR) was flown aboard the University of Washington Convair CV-580 research aircraft and took measurements on 23 flights between August 15 and September 16. On 12 of those flights, BRF (bidirectional reflection function) measurements were obtained over different natural surfaces and ecosystems in southern Africa. The BRF measurements were done to characterize surface anisotropy in support of SAFARI 2000 science objectives principally to validate products from NASA's EOS (Earth Observing System) satellites, and to parameterize and validate BRF models. In this paper we present results of BRFs taken over two EOS validation sites: Skukuza tower, South Africa (25.0 S, 31.5 E) and Mongu tower, Zambia (15.4 S, 23.3 E). The CAR is capable of measuring scattered light in fourteen spectral bands. The scan mirror, rotating at 100 rpm, directs the light into a Dall-Kirkham telescope where the beam is split into nine paths. Eight light beams pass through beam splitters, dichroics, and lenses to individual detectors (0.34-1.27 microns), and finally are registered by eight data channels. They are sampled simultaneously and continuously. The ninth beam passes through a spinning filter wheel to an InSb detector cooled by a Stirling cycle cooler. Signals registered by the ninth data channel are selected from among six spectral channels (1.55-2.30 microns). The filter wheel can either cycle through all six spectral bands at a prescribed interval (usually changing filter every fifth scan line), or lock onto any one of the six spectral bands and sample it continuously. To measure the BRF of the surface-atmosphere system, the University of Washington CV-580 had to bank at a comfortable roll angle of approximately 20 degrees and fly in a circle about 3 km in diameter above the surface for roughly two minutes. Replicated observations (multiple circular orbits) were acquired over selected surfaces so that average BRF smooth out small-scale surface and atmospheric inhomogeneities. At an altitude of 600 m above the targeted surface area and with a 1 degree IFOV, the pixel resolution is about 10 m at nadir and about 270 m at an 80 degree viewing angle from the CAR.
NASA Astrophysics Data System (ADS)
Poryvkina, Larisa; Aleksejev, Valeri; Babichenko, Sergey M.; Ivkina, Tatjana
2011-04-01
The NarTest fluorescent technique is aimed at the detection of analyte of interest in street samples by recognition of its specific spectral patterns in 3-dimentional Spectral Fluorescent Signatures (SFS) measured with NTX2000 analyzer without chromatographic or other separation of controlled substances from a mixture with cutting agents. The illicit drugs have their own characteristic SFS features which can be used for detection and identification of narcotics, however typical street sample consists of a mixture with cutting agents: adulterants and diluents. Many of them interfere the spectral shape of SFS. The expert system based on Artificial Neural Networks (ANNs) has been developed and applied for such pattern recognition in SFS of street samples of illicit drugs.
Parallel detecting, spectroscopic ellipsometers/polarimeters
Furtak, Thomas E.
2002-01-01
The parallel detecting spectroscopic ellipsometer/polarimeter sensor has no moving parts and operates in real-time for in-situ monitoring of the thin film surface properties of a sample within a processing chamber. It includes a multi-spectral source of radiation for producing a collimated beam of radiation directed towards the surface of the sample through a polarizer. The thus polarized collimated beam of radiation impacts and is reflected from the surface of the sample, thereby changing its polarization state due to the intrinsic material properties of the sample. The light reflected from the sample is separated into four separate polarized filtered beams, each having individual spectral intensities. Data about said four individual spectral intensities is collected within the processing chamber, and is transmitted into one or more spectrometers. The data of all four individual spectral intensities is then analyzed using transformation algorithms, in real-time.
Spectral engineering for circular-side square microlasers.
Weng, Hai-Zhong; Yang, Yue-De; Xiao, Jin-Long; Hao, You-Zeng; Huang, Yong-Zhen
2018-04-16
Spectral engineering has been demonstrated for the circular-side square microlasers with an output waveguide butt-coupled to one vertex. By carefully optimizing deformation parameter and waveguide connection angle, undesired high-order transverse modes are suppressed while the mode Q factors and the transverse-mode intervals are enhanced simultaneously for the low-order transverse modes. Dual-mode lasing with pure lasing spectra is realized experimentally for the circular-side square microlasers with side lengths of 16 μm, and the transverse mode intervals can be adjusted from 0.54 to 5.4 nm by changing the deformation parameter. Due to the enhanced mode confinement, single-mode lasing with a side-mode suppression-ratio of 36 dB is achieved for a 10μm-side-length circular-side square microlaser with a 1.5μm-wide waveguide.
Simulation of time-dispersion spectral device with sample spectra accumulation
NASA Astrophysics Data System (ADS)
Zhdanov, Arseny; Khansuvarov, Ruslan; Korol, Georgy
2014-09-01
This research is conducted in order to design a spectral device for light sources power spectrum analysis. The spectral device should process radiation from sources, direct contact with radiation of which is either impossible or undesirable. Such sources include jet blast of an aircraft, optical radiation in metallurgy and textile industry. In proposed spectral device optical radiation is guided out of unfavorable environment via a piece of optical fiber with high dispersion. It is necessary for analysis to make samples of analyzed radiation as short pulses. Dispersion properties of such optical fiber cause spectral decomposition of input optical pulses. The faster time of group delay vary the stronger the spectral decomposition effect. This effect allows using optical fiber with high dispersion as a major element of proposed spectral device. Duration of sample must be much shorter than group delay time difference of a dispersive system. In the given frequency range this characteristic has to be linear. The frequency range is 400 … 500 THz for typical optical fiber. Using photonic-crystal fiber (PCF) gives much wider spectral range for analysis. In this paper we propose simulation of single pulse transmission through dispersive system with linear dispersion characteristic and quadratic-detected output responses accumulation. During simulation we propose studying influence of optical fiber dispersion characteristic angle on spectral measurement results. We also consider pulse duration and group delay time difference impact on output pulse shape and duration. Results show the most suitable dispersion characteristic that allow choosing the structure of PCF - major element of time-dispersion spectral analysis method and required number of samples for reliable assessment of measured spectrum.
Oxytocin's role on the cardiorespiratory activity of endotoxemic rats.
Elorza-Ávila, Ana Rosa; Reyes-Lagos, José Javier; Hadamitzky, Martin; Peña-Castillo, Miguel Ángel; Echeverría, Juan Carlos; Ortiz-Pedroza, María Del Rocío; Lückemann, Laura; Schedlowski, Manfred; Pacheco-López, Gustavo
2017-02-01
Recent findings concerning oxytocin indicate its anti-inflammatory, cardioprotective and parasympathetic modulating properties. In this study, we investigated the effects of systemically applied oxytocin on the cardiorespiratory activity in a rodent model of moderate endotoxemia. Telemetrically recorded electrocardiogram (ECGs) from animals which received lipopolysaccharide (LPS); oxytocin (Ox); lipopolysaccharide+oxytocin (LPS+Ox), or vehicle (V) were analyzed using the ECG-derived respiration (EDR) technique to estimate the respiratory rate. The mean R-R interval and the spectral parameters of heart rate variability (HRV), such as the natural logarithm of the high frequency (lnHF) and low frequency (lnLF) components were also estimated up to 24h after treatment. The endotoxemic animals (LPS) showed an elevated respiratory rate as well as a reduced mean R-R interval, lnHF and lnLF components compared to controls (V) from +5 to +12h after the treatment. The administration of oxytocin significantly attenuated the hyperventilation produced by the LPS-induced endotoxemia (LPS+Ox) and restored the values of the mean R-R interval and such spectral parameters at different time points. Our results support the existence of a link among the respiratory, cardiovascular, and immune systems in which oxytocin seems to act as a potential cardioprotective peptide by favoring cardiac cholinergic autonomic coupling. As a result, oxytocin diminished animal's endotoxemic tachypnea and restored the cardiorespiratory interactions, which was indicated by the spectral components of HRV. Copyright © 2016 Elsevier B.V. All rights reserved.
Li, Zhao-Liang
2018-01-01
Few studies have examined hyperspectral remote-sensing image classification with type-II fuzzy sets. This paper addresses image classification based on a hyperspectral remote-sensing technique using an improved interval type-II fuzzy c-means (IT2FCM*) approach. In this study, in contrast to other traditional fuzzy c-means-based approaches, the IT2FCM* algorithm considers the ranking of interval numbers and the spectral uncertainty. The classification results based on a hyperspectral dataset using the FCM, IT2FCM, and the proposed improved IT2FCM* algorithms show that the IT2FCM* method plays the best performance according to the clustering accuracy. In this paper, in order to validate and demonstrate the separability of the IT2FCM*, four type-I fuzzy validity indexes are employed, and a comparative analysis of these fuzzy validity indexes also applied in FCM and IT2FCM methods are made. These four indexes are also applied into different spatial and spectral resolution datasets to analyze the effects of spectral and spatial scaling factors on the separability of FCM, IT2FCM, and IT2FCM* methods. The results of these validity indexes from the hyperspectral datasets show that the improved IT2FCM* algorithm have the best values among these three algorithms in general. The results demonstrate that the IT2FCM* exhibits good performance in hyperspectral remote-sensing image classification because of its ability to handle hyperspectral uncertainty. PMID:29373548
A 1064 nm dispersive Raman spectral imaging system for food safety and quality evaluation
USDA-ARS?s Scientific Manuscript database
Raman spectral imaging is an effective method to analyze and evaluate chemical composition and structure of a sample, and has many applications for food safety and quality research. This study developed a 1064 nm Raman spectral imaging system for surface and subsurface analysis of food samples. A 10...
Galerkin Spectral Method for the 2D Solitary Waves of Boussinesq Paradigm Equation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christou, M. A.; Christov, C. I.
2009-10-29
We consider the 2D stationary propagating solitary waves of the so-called Boussinesq Paradigm equation. The fourth- order elliptic boundary value problem on infinite interval is solved by a Galerkin spectral method. An iterative procedure based on artificial time ('false transients') and operator splitting is used. Results are obtained for the shapes of the solitary waves for different values of the dispersion parameters for both subcritical and supercritical phase speeds.
Reflectionless Discrete Schrödinger Operators are Spectrally Atypical
NASA Astrophysics Data System (ADS)
VandenBoom, Tom
2017-12-01
We prove that, if an isospectral torus contains a discrete Schrödinger operator with nonconstant potential, the shift dynamics on that torus cannot be minimal. Consequently, we specify a generic sense in which finite unions of nondegenerate closed intervals having capacity one are not the spectrum of any reflectionless discrete Schrödinger operator. We also show that the only reflectionless discrete Schrödinger operators having zero, one, or two spectral gaps are periodic.
Studies on spectral analysis of randomly sampled signals: Application to laser velocimetry data
NASA Technical Reports Server (NTRS)
Sree, David
1992-01-01
Spectral analysis is very useful in determining the frequency characteristics of many turbulent flows, for example, vortex flows, tail buffeting, and other pulsating flows. It is also used for obtaining turbulence spectra from which the time and length scales associated with the turbulence structure can be estimated. These estimates, in turn, can be helpful for validation of theoretical/numerical flow turbulence models. Laser velocimetry (LV) is being extensively used in the experimental investigation of different types of flows, because of its inherent advantages; nonintrusive probing, high frequency response, no calibration requirements, etc. Typically, the output of an individual realization laser velocimeter is a set of randomly sampled velocity data. Spectral analysis of such data requires special techniques to obtain reliable estimates of correlation and power spectral density functions that describe the flow characteristics. FORTRAN codes for obtaining the autocorrelation and power spectral density estimates using the correlation-based slotting technique were developed. Extensive studies have been conducted on simulated first-order spectrum and sine signals to improve the spectral estimates. A first-order spectrum was chosen because it represents the characteristics of a typical one-dimensional turbulence spectrum. Digital prefiltering techniques, to improve the spectral estimates from randomly sampled data were applied. Studies show that the spectral estimates can be increased up to about five times the mean sampling rate.
Wang, Jingzhe; Abulimiti, Aerzuna; Cai, Lianghong
2018-01-01
Soil salinization is one of the most common forms of land degradation. The detection and assessment of soil salinity is critical for the prevention of environmental deterioration especially in arid and semi-arid areas. This study introduced the fractional derivative in the pretreatment of visible and near infrared (VIS–NIR) spectroscopy. The soil samples (n = 400) collected from the Ebinur Lake Wetland, Xinjiang Uyghur Autonomous Region (XUAR), China, were used as the dataset. After measuring the spectral reflectance and salinity in the laboratory, the raw spectral reflectance was preprocessed by means of the absorbance and the fractional derivative order in the range of 0.0–2.0 order with an interval of 0.1. Two different modeling methods, namely, partial least squares regression (PLSR) and random forest (RF) with preprocessed reflectance were used for quantifying soil salinity. The results showed that more spectral characteristics were refined for the spectrum reflectance treated via fractional derivative. The validation accuracies showed that RF models performed better than those of PLSR. The most effective model was established based on RF with the 1.5 order derivative of absorbance with the optimal values of R2 (0.93), RMSE (4.57 dS m−1), and RPD (2.78 ≥ 2.50). The developed RF model was stable and accurate in the application of spectral reflectance for determining the soil salinity of the Ebinur Lake wetland. The pretreatment of fractional derivative could be useful for monitoring multiple soil parameters with higher accuracy, which could effectively help to analyze the soil salinity. PMID:29736341
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferreras, Ignacio; Trujillo, Ignacio, E-mail: i.ferreras@ucl.ac.uk
At the core of the standard cosmological model lies the assumption that the redshift of distant galaxies is independent of photon wavelength. This invariance of cosmological redshift with wavelength is routinely found in all galaxy spectra with a precision of Δ z ∼ 10{sup −4}. The combined use of approximately half a million high-quality galaxy spectra from the Sloan Digital Sky Survey (SDSS) allows us to explore this invariance down to a nominal precision in redshift of 10{sup −6} (statistical). Our analysis is performed over the redshift interval 0.02 < z < 0.25. We use the centroids of spectral linesmore » over the 3700–6800 Å rest-frame optical window. We do not find any difference in redshift between the blue and red sides down to a precision of 10{sup −6} at z ≲ 0.1 and 10{sup −5} at 0.1 ≲ z ≲ 0.25 (i.e., at least an order of magnitude better than with single galaxy spectra). This is the first time the wavelength-independence of the (1 + z ) redshift law is confirmed over a wide spectral window at this precision level. This result holds independently of the stellar population of the galaxies and their kinematical properties. This result is also robust against wavelength calibration issues. The limited spectral resolution ( R ∼ 2000) of the SDSS data, combined with the asymmetric wavelength sampling of the spectral features in the observed restframe due to the (1 + z ) stretching of the lines, prevent our methodology from achieving a precision higher than 10{sup −5}, at z > 0.1. Future attempts to constrain this law will require high quality galaxy spectra at higher resolution ( R ≳ 10,000).« less
Wang, Jingzhe; Ding, Jianli; Abulimiti, Aerzuna; Cai, Lianghong
2018-01-01
Soil salinization is one of the most common forms of land degradation. The detection and assessment of soil salinity is critical for the prevention of environmental deterioration especially in arid and semi-arid areas. This study introduced the fractional derivative in the pretreatment of visible and near infrared (VIS-NIR) spectroscopy. The soil samples ( n = 400) collected from the Ebinur Lake Wetland, Xinjiang Uyghur Autonomous Region (XUAR), China, were used as the dataset. After measuring the spectral reflectance and salinity in the laboratory, the raw spectral reflectance was preprocessed by means of the absorbance and the fractional derivative order in the range of 0.0-2.0 order with an interval of 0.1. Two different modeling methods, namely, partial least squares regression (PLSR) and random forest (RF) with preprocessed reflectance were used for quantifying soil salinity. The results showed that more spectral characteristics were refined for the spectrum reflectance treated via fractional derivative. The validation accuracies showed that RF models performed better than those of PLSR. The most effective model was established based on RF with the 1.5 order derivative of absorbance with the optimal values of R 2 (0.93), RMSE (4.57 dS m -1 ), and RPD (2.78 ≥ 2.50). The developed RF model was stable and accurate in the application of spectral reflectance for determining the soil salinity of the Ebinur Lake wetland. The pretreatment of fractional derivative could be useful for monitoring multiple soil parameters with higher accuracy, which could effectively help to analyze the soil salinity.
Hybrid least squares multivariate spectral analysis methods
Haaland, David M.
2004-03-23
A set of hybrid least squares multivariate spectral analysis methods in which spectral shapes of components or effects not present in the original calibration step are added in a following prediction or calibration step to improve the accuracy of the estimation of the amount of the original components in the sampled mixture. The hybrid method herein means a combination of an initial calibration step with subsequent analysis by an inverse multivariate analysis method. A spectral shape herein means normally the spectral shape of a non-calibrated chemical component in the sample mixture but can also mean the spectral shapes of other sources of spectral variation, including temperature drift, shifts between spectrometers, spectrometer drift, etc. The shape can be continuous, discontinuous, or even discrete points illustrative of the particular effect.
Hybrid least squares multivariate spectral analysis methods
Haaland, David M.
2002-01-01
A set of hybrid least squares multivariate spectral analysis methods in which spectral shapes of components or effects not present in the original calibration step are added in a following estimation or calibration step to improve the accuracy of the estimation of the amount of the original components in the sampled mixture. The "hybrid" method herein means a combination of an initial classical least squares analysis calibration step with subsequent analysis by an inverse multivariate analysis method. A "spectral shape" herein means normally the spectral shape of a non-calibrated chemical component in the sample mixture but can also mean the spectral shapes of other sources of spectral variation, including temperature drift, shifts between spectrometers, spectrometer drift, etc. The "shape" can be continuous, discontinuous, or even discrete points illustrative of the particular effect.
icoshift: A versatile tool for the rapid alignment of 1D NMR spectra
NASA Astrophysics Data System (ADS)
Savorani, F.; Tomasi, G.; Engelsen, S. B.
2010-02-01
The increasing scientific and industrial interest towards metabonomics takes advantage from the high qualitative and quantitative information level of nuclear magnetic resonance (NMR) spectroscopy. However, several chemical and physical factors can affect the absolute and the relative position of an NMR signal and it is not always possible or desirable to eliminate these effects a priori. To remove misalignment of NMR signals a posteriori, several algorithms have been proposed in the literature. The icoshift program presented here is an open source and highly efficient program designed for solving signal alignment problems in metabonomic NMR data analysis. The icoshift algorithm is based on correlation shifting of spectral intervals and employs an FFT engine that aligns all spectra simultaneously. The algorithm is demonstrated to be faster than similar methods found in the literature making full-resolution alignment of large datasets feasible and thus avoiding down-sampling steps such as binning. The algorithm uses missing values as a filling alternative in order to avoid spectral artifacts at the segment boundaries. The algorithm is made open source and the Matlab code including documentation can be downloaded from www.models.life.ku.dk.
Liu, Jingfei; Declercq, Nico F
2017-03-01
An analytical and experimental study of the pulsed ultrasonic comb filtering effect is presented in this work intending to provide a fundamental tool for data analysis and phenomenon understanding in pulsed ultrasonics. The basic types of comb filter, feedforward and feedback filters, are numerically simulated and demonstrated. The characteristic features of comb filters, which include the formula for determining the locations of the spectral peaks or notches and the relationship between its temporal characteristics (relative time delay between constituent pulses) and its spectral characteristics (frequency interval between peaks or notches), are theoretically derived. To demonstrate the applicability of the comb filtering effect, it is applied to measuring the sound velocities and thickness of a thin plate sample. It is proven that the comb filtering effect based method not only is capable of accurate measurements, but also has advantages over the conventional time-of-flight based method in thin plate measurements. Furthermore, the principles developed in this study have potential applications in any pulsed ultrasonic cases where the output signal shows comb filter features. Copyright © 2016 Elsevier B.V. All rights reserved.
Effect of non-Poisson samples on turbulence spectra from laser velocimetry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sree, D.; Kjelgaard, S.O.; Sellers, W.L. III
1994-12-01
Spectral estimations from LV data are typically based on the assumption of a Poisson sampling process. It is demonstrated here that the sampling distribution must be considered before spectral estimates are used to infer turbulence scales. A non-Poisson sampling process can occur if there is nonhomogeneous distribution of particles in the flow. Based on the study of a simulated first-order spectrum, it has been shown that a non-Poisson sampling process causes the estimated spectrum to deviate from the true spectrum. Also, in this case the prefiltering techniques do not improve the spectral estimates at higher frequencies. 4 refs.
Application LANDSAT imagery to geologic mapping in the ice-free valleys of Antarctica
NASA Technical Reports Server (NTRS)
Houston, R. S. (Principal Investigator); Marrs, R. W.; Smithson, S. B.
1976-01-01
The author has identified the following significant results. Studies in the Ice-Free Valleys are resulted in the compilation of a sizeable library of maps and publications. Rock reflectance measurements were taken during the Antarctic summer of 1973. Spectral reflectance of rocks (mostly mafic lava flows) in the McMurdo and Ice-Free Valleys areas were measured using a filter wheel photometer equipped to measure reflectances in the four Landsat bands. A series of samples were collected at regular intervals across a large differentiated, mafic sill near Lake Vida. Chemical analyses of the sample suggest that the tonal variations in this sill are controlled by changes in the iron content of the rock. False color images were prepared for a number of areas by the diazo method and with an optical multispectral biviewer. These images were useful in defining boundaries of sea ice, snow cover, and in the study of ablating glaciers, but were not very useful for rock discrimination.
Methods for spectral image analysis by exploiting spatial simplicity
Keenan, Michael R.
2010-05-25
Several full-spectrum imaging techniques have been introduced in recent years that promise to provide rapid and comprehensive chemical characterization of complex samples. One of the remaining obstacles to adopting these techniques for routine use is the difficulty of reducing the vast quantities of raw spectral data to meaningful chemical information. Multivariate factor analysis techniques, such as Principal Component Analysis and Alternating Least Squares-based Multivariate Curve Resolution, have proven effective for extracting the essential chemical information from high dimensional spectral image data sets into a limited number of components that describe the spectral characteristics and spatial distributions of the chemical species comprising the sample. There are many cases, however, in which those constraints are not effective and where alternative approaches may provide new analytical insights. For many cases of practical importance, imaged samples are "simple" in the sense that they consist of relatively discrete chemical phases. That is, at any given location, only one or a few of the chemical species comprising the entire sample have non-zero concentrations. The methods of spectral image analysis of the present invention exploit this simplicity in the spatial domain to make the resulting factor models more realistic. Therefore, more physically accurate and interpretable spectral and abundance components can be extracted from spectral images that have spatially simple structure.
Methods for spectral image analysis by exploiting spatial simplicity
Keenan, Michael R.
2010-11-23
Several full-spectrum imaging techniques have been introduced in recent years that promise to provide rapid and comprehensive chemical characterization of complex samples. One of the remaining obstacles to adopting these techniques for routine use is the difficulty of reducing the vast quantities of raw spectral data to meaningful chemical information. Multivariate factor analysis techniques, such as Principal Component Analysis and Alternating Least Squares-based Multivariate Curve Resolution, have proven effective for extracting the essential chemical information from high dimensional spectral image data sets into a limited number of components that describe the spectral characteristics and spatial distributions of the chemical species comprising the sample. There are many cases, however, in which those constraints are not effective and where alternative approaches may provide new analytical insights. For many cases of practical importance, imaged samples are "simple" in the sense that they consist of relatively discrete chemical phases. That is, at any given location, only one or a few of the chemical species comprising the entire sample have non-zero concentrations. The methods of spectral image analysis of the present invention exploit this simplicity in the spatial domain to make the resulting factor models more realistic. Therefore, more physically accurate and interpretable spectral and abundance components can be extracted from spectral images that have spatially simple structure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wohletz, K.H.; Raymond, R. Jr.; Rawson, G.
1988-01-01
The MISTY PICTURE surface burst was detonated at the White Sands Missle range in May of 1987. The Los Alamos National Laboratory dust characterization program was expanded to help correlate and interrelate aspects of the overall MISTY PICTURE dust and ejecta characterization program. Pre-shot sampling of the test bed included composite samples from 15 to 75 m distance from Surface Ground Zero (SGZ) representing depths down to 2.5 m, interval samples from 15 to 25 m from SGZ representing depths down to 3m, and samples of surface material (top 0.5 cm) out to distances of 190 m from SGZ. Sweep-upmore » samples were collected in GREG/SNOB gages located within the DPR. All samples were dry-sieved between 8.0 mm and 0.045 mm (16 size fractures); selected samples were analyzed for fines by a contrifugal settling technique. The size distributions were analyzed using spectral decomposition based upon a sequential fragmentation model. Results suggest that the same particle size subpopulations are present in the ejecta, fallout, and sweep-up samples as are present in the pre-shot test bed. The particle size distribution in post-shot environments apparently can be modelled taking into account heterogeneities in the pre-shot test bed and dominant wind direction during and following the shot. 13 refs., 12 figs., 2 tabs.« less
Rosenblum, Michael A; Laan, Mark J van der
2009-01-07
The validity of standard confidence intervals constructed in survey sampling is based on the central limit theorem. For small sample sizes, the central limit theorem may give a poor approximation, resulting in confidence intervals that are misleading. We discuss this issue and propose methods for constructing confidence intervals for the population mean tailored to small sample sizes. We present a simple approach for constructing confidence intervals for the population mean based on tail bounds for the sample mean that are correct for all sample sizes. Bernstein's inequality provides one such tail bound. The resulting confidence intervals have guaranteed coverage probability under much weaker assumptions than are required for standard methods. A drawback of this approach, as we show, is that these confidence intervals are often quite wide. In response to this, we present a method for constructing much narrower confidence intervals, which are better suited for practical applications, and that are still more robust than confidence intervals based on standard methods, when dealing with small sample sizes. We show how to extend our approaches to much more general estimation problems than estimating the sample mean. We describe how these methods can be used to obtain more reliable confidence intervals in survey sampling. As a concrete example, we construct confidence intervals using our methods for the number of violent deaths between March 2003 and July 2006 in Iraq, based on data from the study "Mortality after the 2003 invasion of Iraq: A cross sectional cluster sample survey," by Burnham et al. (2006).
Vegetation monitoring and classification using NOAA/AVHRR satellite data
NASA Technical Reports Server (NTRS)
Greegor, D. H., Jr.; Norwine, J. R.
1983-01-01
A vegetation gradient model, based on a new surface hydrologic index and NOAA/AVHRR meteorological satellite data, has been analyzed along a 1300 km east-west transect across the state of Texas. The model was developed to test the potential usefulness of such low-resolution data for vegetation stratification and monitoring. Normalized Difference values (ratio of AVHRR bands 1 and 2, considered to be an index of greenness) were determined and evaluated against climatological and vegetation characteristics at 50 sample locations (regular intervals of 0.25 deg longitude) along the transect on five days in 1980. Statistical treatment of the data indicate that a multivariate model incorporating satellite-measured spectral greenness values and a surface hydrologic factor offer promise as a new technique for regional-scale vegetation stratification and monitoring.
Fundamental relations between short-term RR interval and arterial pressure oscillations in humans
NASA Technical Reports Server (NTRS)
Taylor, J. A.; Eckberg, D. L.
1996-01-01
BACKGROUND: One of the principal explanations for respiratory sinus arrhythmia is that it reflects arterial baroreflex buffering of respiration-induced arterial pressure fluctuations. If this explanation is correct, then elimination of RR interval fluctuations should increase respiratory arterial pressure fluctuations. METHODS AND RESULTS: We measured RR interval and arterial pressure fluctuations during normal sinus rhythm and fixed-rate atrial pacing at 17.2+/-1.8 (SEM) beats per minute greater than the sinus rate in 16 healthy men and 4 healthy women, 20 to 34 years of age. Measurements were made during controlled-frequency breathing (15 breaths per minute or 0.25 Hz) with subjects in the supine and 40 degree head-up tilt positions. We characterized RR interval and arterial pressure variabilities in low-frequency (0.05 to 0.15 Hz) and respiratory-frequency (0.20 to 0.30 Hz) ranges with fast Fourier transform power spectra and used cross-spectral analysis to determine the phase relation between the two signals. As expected, cardiac pacing eliminated beat-to-beat RR interval variability. Against expectations, however, cardiac pacing in the supine position significantly reduced arterial pressure oscillations in the respiratory frequency (systolic, 6.8+/-1.8 to 2.9 +/-0.6 mm Hg2/Hz, P=.017). In contrast, cardiac pacing in the 40 degree tilt position increased arterial pressure variability (systolic, 8.0+/-1.8 to 10.8 +/-2.6, P=.027). Cross-spectral analysis showed that 40 degree tilt shifted the phase relation between systolic pressure and RR interval at the respiratory frequency from positive to negative (9 +/-7 degrees versus -17+/-11 degrees, P=.04); that is, in the supine position, RR interval changes appeared to lead arterial pressure changes, and in the upright position, RR interval changes appeared to follow arterial pressure changes. CONCLUSIONS: These results demonstrate that respiratory sinus arrhythmia can actually contribute to respiratory arterial pressure fluctuations. Therefore, respiratory sinus arrhythmia does not represent simple baroreflex buffering of arterial pressure.
Analysis of Volcanic Processes at Kilauea Volcano Using an Airborne Imaging Interferometer
NASA Astrophysics Data System (ADS)
Wright, R.; Lucey, P. G.; Garbeil, H.; Pilger, E. J.; Wood, M.; Honniball, C.; Gabrieli, A.
2017-12-01
Measurements of thermal emittance in tens of narrow, contiguous wavebands, allow for the derivation of laboratory quality spectra remotely, from which the chemical composition and physical properties of targets can be determined. The TIRCIS instrument (Thermal Infra-Red Compact Imaging Spectrometer), developed at the Hawaii Institute of Geophysics and Planetology, uses a Fabry-Perot interferometer, an uncooled microbolometer array, and push-broom scanning to acquire hyperspectral image data in the 8-14 micron spectral range. Radiometric calibration is provided by blackbody targets while spectral calibration is achieved using monochromatic light sources. The instrument has a mass of <15 kg and dimensions of 53 cm × 25 cm × 22 cm, and has been designed to be compatible with integration into a micro-satellite platform. (A precursor to this instrument was launched onboard a 55 kg microsatellite as part of the ORS-4 mission in October 2015.) Over the wavelength interval of up to 50 spectral samples are possible, and signal-to-noise ratios of 200-1600:1 have been measured for targets with temperatures covering those of interest to Earth scientists. In this presentation we will discuss how the instrument works, its spectro-radiometric performance (and performance model), and show laboratory measurements that illustrate how the instrument would be able to quantify thermal emission from active lavas, the mineralogy of volcanic rocks, and the composition of volcanic gas plumes. Finally, we will present data obtained during test flights over Kilauea volcano, Hawaii.
Wang, Yin; Zhao, Nan-jing; Liu, Wen-qing; Yu, Yang; Fang, Li; Meng, De-shuo; Hu, Li; Zhang, Da-hai; Ma, Min-jun; Xiao, Xue; Wang, Yu; Liu, Jian-guo
2015-02-01
In recent years, the technology of laser induced breakdown spectroscopy has been developed rapidly. As one kind of new material composition detection technology, laser induced breakdown spectroscopy can simultaneously detect multi elements fast and simply without any complex sample preparation and realize field, in-situ material composition detection of the sample to be tested. This kind of technology is very promising in many fields. It is very important to separate, fit and extract spectral feature lines in laser induced breakdown spectroscopy, which is the cornerstone of spectral feature recognition and subsequent elements concentrations inversion research. In order to realize effective separation, fitting and extraction of spectral feature lines in laser induced breakdown spectroscopy, the original parameters for spectral lines fitting before iteration were analyzed and determined. The spectral feature line of' chromium (Cr I : 427.480 nm) in fly ash gathered from a coal-fired power station, which was overlapped with another line(FeI: 427.176 nm), was separated from the other one and extracted by using damped least squares method. Based on Gauss-Newton iteration, damped least squares method adds damping factor to step and adjust step length dynamically according to the feedback information after each iteration, in order to prevent the iteration from diverging and make sure that the iteration could converge fast. Damped least squares method helps to obtain better results of separating, fitting and extracting spectral feature lines and give more accurate intensity values of these spectral feature lines: The spectral feature lines of chromium in samples which contain different concentrations of chromium were separated and extracted. And then, the intensity values of corresponding spectral lines were given by using damped least squares method and least squares method separately. The calibration curves were plotted, which showed the relationship between spectral line intensity values and chromium concentrations in different samples. And then their respective linear correlations were compared. The experimental results showed that the linear correlation of the intensity values of spectral feature lines and the concentrations of chromium in different samples, which was obtained by damped least squares method, was better than that one obtained by least squares method. And therefore, damped least squares method was stable, reliable and suitable for separating, fitting and extracting spectral feature lines in laser induced breakdown spectroscopy.
NASA Astrophysics Data System (ADS)
Banas, Krzysztof; Banas, Agnieszka M.; Heussler, Sascha P.; Breese, Mark B. H.
2018-01-01
In the contemporary spectroscopy there is a trend to record spectra with the highest possible spectral resolution. This is clearly justified if the spectral features in the spectrum are very narrow (for example infra-red spectra of gas samples). However there is a plethora of samples (in the liquid and especially in the solid form) where there is a natural spectral peak broadening due to collisions and proximity predominately. Additionally there is a number of portable devices (spectrometers) with inherently restricted spectral resolution, spectral range or both, which are extremely useful in some field applications (archaeology, agriculture, food industry, cultural heritage, forensic science). In this paper the investigation of the influence of spectral resolution, spectral range and signal-to-noise ratio on the identification of high explosive substances by applying multivariate statistical methods on the Fourier transform infra-red spectral data sets is studied. All mathematical procedures on spectral data for dimension reduction, clustering and validation were implemented within R open source environment.
Zhang, Da; She, Jin; Zhang, Zhengbo; Yu, Mengsun
2014-06-11
Investigating the responses of autonomic nervous system (ANS) in hypoxia may provide some knowledge about the mechanism of neural control and rhythmic adjustment. The integrated cardiac and respiratory system display complicated dynamics that are affected by intrinsic feedback mechanisms controlling their interaction. To probe how the cardiac and respiratory system adjust their rhythms in different simulated altitudes, we studied heart rate variability (HRV) in frequency domain, the complexity of heartbeat series and cardiorespiratory phase synchronization (CRPS) between heartbeat intervals and respiratory cycles. In this study, twelve male subjects were exposed to simulated altitude of sea level, 3000 m and 4000 m in a hypobaric chamber. HRV was assessed by power spectral analysis. The complexity of heartbeat series was quantified by sample entropy (SampEn). CRPS was determined by cardiorespiratory synchrogram. The power spectral HRV indices at all frequency bands depressed according to the increase of altitude. The SampEn of heartbeat series increased significantly with the altitude (P < 0.01). The duration of CRPS epochs at 3000 m was not significantly different from that at sea level. However, it was significantly longer at 4000 m (P < 0.01). Our results suggest the phenomenon of CRPS exists in normal subjects when they expose to acute hypoxia. Further, the autonomic regulation has a significantly stronger influence on CRPS in acute hypoxia. The changes of CRPS and HRV parameters revealed the different regulatory mechanisms of the cardiac and respiratory system at high altitude.
ElMasry, Gamal; Nakauchi, Shigeki
2016-03-01
A simulation method for approximating spectral signatures of minced meat samples was developed depending on concentrations and optical properties of the major chemical constituents. Minced beef samples of different compositions scanned on a near-infrared spectroscopy and on a hyperspectral imaging system were examined. Chemical composition determined heuristically and optical properties collected from authenticated references were simulated to approximate samples' spectral signatures. In short-wave infrared range, the resulting spectrum equals the sum of the absorption of three individual absorbers, that is, water, protein, and fat. By assuming homogeneous distributions of the main chromophores in the mince samples, the obtained absorption spectra are found to be a linear combination of the absorption spectra of the major chromophores present in the sample. Results revealed that developed models were good enough to derive spectral signatures of minced meat samples with a reasonable level of robustness of a high agreement index value more than 0.90 and ratio of performance to deviation more than 1.4.
Investigation of spectral analysis techniques for randomly sampled velocimetry data
NASA Technical Reports Server (NTRS)
Sree, Dave
1993-01-01
It is well known that velocimetry (LV) generates individual realization velocity data that are randomly or unevenly sampled in time. Spectral analysis of such data to obtain the turbulence spectra, and hence turbulence scales information, requires special techniques. The 'slotting' technique of Mayo et al, also described by Roberts and Ajmani, and the 'Direct Transform' method of Gaster and Roberts are well known in the LV community. The slotting technique is faster than the direct transform method in computation. There are practical limitations, however, as to how a high frequency and accurate estimate can be made for a given mean sampling rate. These high frequency estimates are important in obtaining the microscale information of turbulence structure. It was found from previous studies that reliable spectral estimates can be made up to about the mean sampling frequency (mean data rate) or less. If the data were evenly samples, the frequency range would be half the sampling frequency (i.e. up to Nyquist frequency); otherwise, aliasing problem would occur. The mean data rate and the sample size (total number of points) basically limit the frequency range. Also, there are large variabilities or errors associated with the high frequency estimates from randomly sampled signals. Roberts and Ajmani proposed certain pre-filtering techniques to reduce these variabilities, but at the cost of low frequency estimates. The prefiltering acts as a high-pass filter. Further, Shapiro and Silverman showed theoretically that, for Poisson sampled signals, it is possible to obtain alias-free spectral estimates far beyond the mean sampling frequency. But the question is, how far? During his tenure under 1993 NASA-ASEE Summer Faculty Fellowship Program, the author investigated from his studies on the spectral analysis techniques for randomly sampled signals that the spectral estimates can be enhanced or improved up to about 4-5 times the mean sampling frequency by using a suitable prefiltering technique. But, this increased bandwidth comes at the cost of the lower frequency estimates. The studies further showed that large data sets of the order of 100,000 points, or more, high data rates, and Poisson sampling are very crucial for obtaining reliable spectral estimates from randomly sampled data, such as LV data. Some of the results of the current study are presented.
Spectral analysis of a family of binary inflation rules
NASA Astrophysics Data System (ADS)
Baake, Michael; Grimm, Uwe; Mañibo, Neil
2018-01-01
The family of primitive binary substitutions defined by 1 \\mapsto 0 \\mapsto 0 1^m with m\\in N is investigated. The spectral type of the corresponding diffraction measure is analysed for its geometric realisation with prototiles (intervals) of natural length. Apart from the well-known Fibonacci inflation (m=1 ), the inflation rules either have integer inflation factors, but non-constant length, or are of non-Pisot type. We show that all of them have singular diffraction, either of pure point type or essentially singular continuous.
ERIC Educational Resources Information Center
Du, Yunfei
This paper discusses the impact of sampling error on the construction of confidence intervals around effect sizes. Sampling error affects the location and precision of confidence intervals. Meta-analytic resampling demonstrates that confidence intervals can haphazardly bounce around the true population parameter. Special software with graphical…
Fu, Fan; Sun, Shengjun; Liu, Liping; Li, Jianying; Su, Yaping; Li, Yingying
2018-04-19
The computed tomography angiography (CTA) spot sign is a validated predictor of haematoma expansion (HE) in spontaneous intracerebral haemorrhage (SICH). We investigated whether defining the iodine concentration (IC) inside the spot sign and the haematoma on Gemstone spectral imaging (GSI) would improve its sensitivity and specificity for predicting HE. From 2014 to 2016, we prospectively enrolled 65 SICH patients who underwent single-phase spectral CTA within 6 h. Logistic regression was performed to assess the risk factors for HE. The predictive performance of individual spot sign characteristics was examined via receiver operating characteristic (ROC) analysis. The spot sign was detected in 46.1% (30/65) of patients. ROC analysis indicated that IC inside the spot sign had the greatest area under the ROC curve for HE (0.858; 95% confidence interval, 0.727-0.989; p = 0.003). Multivariate analysis found that spot sign with higher IC (i.e. IC > 7.82 100 μg/ml) was an independent predictor of HE (odds ratio = 34.27; 95% confidence interval, 5.608-209.41; p < 0.001) with sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 0.81, 0.75, 0.90 and 0.60, respectively; while the spot sign showed sensitivity, specificity, PPV and NPV of 0.81, 0.79, 0.73 and 0.86. Logistic regression analysis indicated that the IC in haematomas was independently associated with HE (odds ratio = 1.525; 95% confidence interval, 1.041-2.235; p = 0.030). ICs in haematoma and in spot sign were all independently associated with HE. IC analysis in spectral imaging may help to identify SICH patients for targeted haemostatic therapy. • Iodine concentration in spot sign and haematoma can predict haematoma expansion • Spectral imaging could measure the IC inside the spot sign and haematoma • IC in spot sign improved the positive predictive value (PPV) cf. CTA.
Bioactivity studies on TiO₂-bearing Na₂O-CaO-SiO₂-B₂O₃ glasses.
Jagan Mohini, G; Sahaya Baskaran, G; Ravi Kumar, V; Piasecki, M; Veeraiah, N
2015-12-01
Soda lime silica borate glasses mixed with different concentrations of TiO2 are synthesized by the melt-quenching technique. As a part of study on bioactivity of these glasses, the samples were immersed in simulated body fluid (SBF) solution for prolonged times (~21 days) during which weight loss along with pH measurements is carried out at specific intervals of time. The XRD and SEM analyses of post-immersed samples confirm the formation of crystalline hydroxyapatite layer (HA) on the surface of the samples. To assess the role of TiO2 on the formation of HA layer and degradability of the samples the spectroscopic studies viz. optical absorption and IR spectral studies on post- and pre-immersed samples have been carried out. The analysis of the results of degradability together with spectroscopic studies as a function of TiO2 concentration indicated that about 6.0 mol% of TiO2 is the optimal concentration for achieving better bioactivity of these glasses. The presence of the maximal concentration octahedral titanium ions in this glass that facilitates the formation of HA layer is found to be the reason for such a higher bioactivity. Copyright © 2015 Elsevier B.V. All rights reserved.
Extragalactic Peaked-spectrum Radio Sources at Low Frequencies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Callingham, J. R.; Gaensler, B. M.; Sadler, E. M.
We present a sample of 1483 sources that display spectral peaks between 72 MHz and 1.4 GHz, selected from the GaLactic and Extragalactic All-sky Murchison Widefield Array (GLEAM) survey. The GLEAM survey is the widest fractional bandwidth all-sky survey to date, ideal for identifying peaked-spectrum sources at low radio frequencies. Our peaked-spectrum sources are the low-frequency analogs of gigahertz-peaked spectrum (GPS) and compact-steep spectrum (CSS) sources, which have been hypothesized to be the precursors to massive radio galaxies. Our sample more than doubles the number of known peaked-spectrum candidates, and 95% of our sample have a newly characterized spectral peak.more » We highlight that some GPS sources peaking above 5 GHz have had multiple epochs of nuclear activity, and we demonstrate the possibility of identifying high-redshift ( z > 2) galaxies via steep optically thin spectral indices and low observed peak frequencies. The distribution of the optically thick spectral indices of our sample is consistent with past GPS/CSS samples but with a large dispersion, suggesting that the spectral peak is a product of an inhomogeneous environment that is individualistic. We find no dependence of observed peak frequency with redshift, consistent with the peaked-spectrum sample comprising both local CSS sources and high-redshift GPS sources. The 5 GHz luminosity distribution lacks the brightest GPS and CSS sources of previous samples, implying that a convolution of source evolution and redshift influences the type of peaked-spectrum sources identified below 1 GHz. Finally, we discuss sources with optically thick spectral indices that exceed the synchrotron self-absorption limit.« less
Tawfik, Ahmed M; Razek, Ahmed A; Elhawary, Galal; Batouty, Nihal M
2014-01-01
To evaluate the effect of increasing the sampling interval from 1 second (1 image per second) to 2 seconds (1 image every 2 seconds) on computed tomographic (CT) perfusion (CTP) of head and neck tumors. Twenty patients underwent CTP studies of head and neck tumors with images acquired in cine mode for 50 seconds using sampling interval of 1 second. Using deconvolution-based software, analysis of CTP was done with sampling interval of 1 second and then 2 seconds. Perfusion maps representing blood flow, blood volume, mean transit time, and permeability surface area product (PS) were obtained. Quantitative tumor CTP values were compared between the 2 sampling intervals. Two blinded radiologists compared the subjective quality of CTP maps using a 3-point scale between the 2 sampling intervals. Radiation dose parameters were recorded for the 2 sampling interval rates. No significant differences were observed between the means of the 4 perfusion parameters generated using both sampling intervals; all P >0.05. The 95% limits of agreement between the 2 sampling intervals were -65.9 to 48.1) mL/min per 100 g for blood flow, -3.6 to 3.1 mL/100 g for blood volume, -2.9 to 3.8 seconds for mean transit time, and -10.0 to 12.5 mL/min per 100 g for PS. There was no significant difference between the subjective quality scores of CTP maps obtained using the 2 sampling intervals; all P > 0.05. Radiation dose was halved when sampling interval increased from 1 to 2 seconds. Increasing the sampling interval rate to 1 image every 2 seconds does not compromise the image quality and has no significant effect on quantitative perfusion parameters of head and neck tumors. The radiation dose is halved.
Evaluation of 1H NMR metabolic profiling using biofluid mixture design.
Athersuch, Toby J; Malik, Shahid; Weljie, Aalim; Newton, Jack; Keun, Hector C
2013-07-16
A strategy for evaluating the performance of quantitative spectral analysis tools in conditions that better approximate background variation in a metabonomics experiment is presented. Three different urine samples were mixed in known proportions according to a {3, 3} simplex lattice experimental design and analyzed in triplicate by 1D (1)H NMR spectroscopy. Fifty-four urinary metabolites were subsequently quantified from the sample spectra using two methods common in metabolic profiling studies: (1) targeted spectral fitting and (2) targeted spectral integration. Multivariate analysis using partial least-squares (PLS) regression showed the latent structure of the spectral set recapitulated the experimental mixture design. The goodness-of-prediction statistic (Q(2)) of each metabolite variable in a PLS model was calculated as a metric for the reliability of measurement, across the sample compositional space. Several metabolites were observed to have low Q(2) values, largely as a consequence of their spectral resonances having low s/n or strong overlap with other sample components. This strategy has the potential to allow evaluation of spectral features obtained from metabolic profiling platforms in the context of the compositional background found in real biological sample sets, which may be subject to considerable variation. We suggest that it be incorporated into metabolic profiling studies to improve the estimation of matrix effects that confound accurate metabolite measurement. This novel method provides a rational basis for exploiting information from several samples in an efficient manner and avoids the use of multiple spike-in authentic standards, which may be difficult to obtain.
NASA Technical Reports Server (NTRS)
Marcin, Martin; Abramovici, Alexander
2008-01-01
The software of a commercially available digital radio receiver has been modified to make the receiver function as a two-channel low-noise phase meter. This phase meter is a prototype in the continuing development of a phase meter for a system in which radiofrequency (RF) signals in the two channels would be outputs of a spaceborne heterodyne laser interferometer for detecting gravitational waves. The frequencies of the signals could include a common Doppler-shift component of as much as 15 MHz. The phase meter is required to measure the relative phases of the signals in the two channels at a sampling rate of 10 Hz at a root power spectral density <5 microcycle/(Hz)1/2 and to be capable of determining the power spectral density of the phase difference over the frequency range from 1 mHz to 1 Hz. Such a phase meter could also be used on Earth to perform similar measurements in laser metrology of moving bodies. To illustrate part of the principle of operation of the phase meter, the figure includes a simplified block diagram of a basic singlechannel digital receiver. The input RF signal is first fed to the input terminal of an analog-to-digital converter (ADC). To prevent aliasing errors in the ADC, the sampling rate must be at least twice the input signal frequency. The sampling rate of the ADC is governed by a sampling clock, which also drives a digital local oscillator (DLO), which is a direct digital frequency synthesizer. The DLO produces samples of sine and cosine signals at a programmed tuning frequency. The sine and cosine samples are mixed with (that is, multiplied by) the samples from the ADC, then low-pass filtered to obtain in-phase (I) and quadrature (Q) signal components. A digital signal processor (DSP) computes the ratio between the Q and I components, computes the phase of the RF signal (relative to that of the DLO signal) as the arctangent of this ratio, and then averages successive such phase values over a time interval specified by the user.
West, A G; Goldsmith, G R; Matimati, I; Dawson, T E
2011-08-30
Previous studies have demonstrated the potential for large errors to occur when analyzing waters containing organic contaminants using isotope ratio infrared spectroscopy (IRIS). In an attempt to address this problem, IRIS manufacturers now provide post-processing spectral analysis software capable of identifying samples with the types of spectral interference that compromises their stable isotope analysis. Here we report two independent tests of this post-processing spectral analysis software on two IRIS systems, OA-ICOS (Los Gatos Research Inc.) and WS-CRDS (Picarro Inc.). Following a similar methodology to a previous study, we cryogenically extracted plant leaf water and soil water and measured the δ(2)H and δ(18)O values of identical samples by isotope ratio mass spectrometry (IRMS) and IRIS. As an additional test, we analyzed plant stem waters and tap waters by IRMS and IRIS in an independent laboratory. For all tests we assumed that the IRMS value represented the "true" value against which we could compare the stable isotope results from the IRIS methods. Samples showing significant deviations from the IRMS value (>2σ) were considered to be contaminated and representative of spectral interference in the IRIS measurement. Over the two studies, 83% of plant species were considered contaminated on OA-ICOS and 58% on WS-CRDS. Post-analysis, spectra were analyzed using the manufacturer's spectral analysis software, in order to see if the software correctly identified contaminated samples. In our tests the software performed well, identifying all the samples with major errors. However, some false negatives indicate that user evaluation and testing of the software are necessary. Repeat sampling of plants showed considerable variation in the discrepancies between IRIS and IRMS. As such, we recommend that spectral analysis of IRIS data must be incorporated into standard post-processing routines. Furthermore, we suggest that the results from spectral analysis be included when reporting stable isotope data from IRIS. Copyright © 2011 John Wiley & Sons, Ltd.
Application of hyperspectral imaging for characterization of intramuscular fat distribution in beef
USDA-ARS?s Scientific Manuscript database
In this study, a hyperspectral imaging system in the spectral region of 400–1000 nm was used for visualization and determination of intramuscular fat concentration in beef samples. Hyperspectral images were acquired for beef samples, and spectral information was then extracted from each single sampl...
Gilmore, Adam Matthew
2014-01-01
Contemporary spectrofluorimeters comprise exciting light sources, excitation and emission monochromators, and detectors that without correction yield data not conforming to an ideal spectral response. The correction of the spectral properties of the exciting and emission light paths first requires calibration of the wavelength and spectral accuracy. The exciting beam path can be corrected up to the sample position using a spectrally corrected reference detection system. The corrected reference response accounts for both the spectral intensity and drift of the exciting light source relative to emission and/or transmission detector responses. The emission detection path must also be corrected for the combined spectral bias of the sample compartment optics, emission monochromator, and detector. There are several crucial issues associated with both excitation and emission correction including the requirement to account for spectral band-pass and resolution, optical band-pass or neutral density filters, and the position and direction of polarizing elements in the light paths. In addition, secondary correction factors are described including (1) subtraction of the solvent's fluorescence background, (2) removal of Rayleigh and Raman scattering lines, as well as (3) correcting for sample concentration-dependent inner-filter effects. The importance of the National Institute of Standards and Technology (NIST) traceable calibration and correction protocols is explained in light of valid intra- and interlaboratory studies and effective spectral qualitative and quantitative analyses including multivariate spectral modeling.
Augmented classical least squares multivariate spectral analysis
Haaland, David M.; Melgaard, David K.
2004-02-03
A method of multivariate spectral analysis, termed augmented classical least squares (ACLS), provides an improved CLS calibration model when unmodeled sources of spectral variation are contained in a calibration sample set. The ACLS methods use information derived from component or spectral residuals during the CLS calibration to provide an improved calibration-augmented CLS model. The ACLS methods are based on CLS so that they retain the qualitative benefits of CLS, yet they have the flexibility of PLS and other hybrid techniques in that they can define a prediction model even with unmodeled sources of spectral variation that are not explicitly included in the calibration model. The unmodeled sources of spectral variation may be unknown constituents, constituents with unknown concentrations, nonlinear responses, non-uniform and correlated errors, or other sources of spectral variation that are present in the calibration sample spectra. Also, since the various ACLS methods are based on CLS, they can incorporate the new prediction-augmented CLS (PACLS) method of updating the prediction model for new sources of spectral variation contained in the prediction sample set without having to return to the calibration process. The ACLS methods can also be applied to alternating least squares models. The ACLS methods can be applied to all types of multivariate data.
Augmented Classical Least Squares Multivariate Spectral Analysis
Haaland, David M.; Melgaard, David K.
2005-07-26
A method of multivariate spectral analysis, termed augmented classical least squares (ACLS), provides an improved CLS calibration model when unmodeled sources of spectral variation are contained in a calibration sample set. The ACLS methods use information derived from component or spectral residuals during the CLS calibration to provide an improved calibration-augmented CLS model. The ACLS methods are based on CLS so that they retain the qualitative benefits of CLS, yet they have the flexibility of PLS and other hybrid techniques in that they can define a prediction model even with unmodeled sources of spectral variation that are not explicitly included in the calibration model. The unmodeled sources of spectral variation may be unknown constituents, constituents with unknown concentrations, nonlinear responses, non-uniform and correlated errors, or other sources of spectral variation that are present in the calibration sample spectra. Also, since the various ACLS methods are based on CLS, they can incorporate the new prediction-augmented CLS (PACLS) method of updating the prediction model for new sources of spectral variation contained in the prediction sample set without having to return to the calibration process. The ACLS methods can also be applied to alternating least squares models. The ACLS methods can be applied to all types of multivariate data.
Augmented Classical Least Squares Multivariate Spectral Analysis
Haaland, David M.; Melgaard, David K.
2005-01-11
A method of multivariate spectral analysis, termed augmented classical least squares (ACLS), provides an improved CLS calibration model when unmodeled sources of spectral variation are contained in a calibration sample set. The ACLS methods use information derived from component or spectral residuals during the CLS calibration to provide an improved calibration-augmented CLS model. The ACLS methods are based on CLS so that they retain the qualitative benefits of CLS, yet they have the flexibility of PLS and other hybrid techniques in that they can define a prediction model even with unmodeled sources of spectral variation that are not explicitly included in the calibration model. The unmodeled sources of spectral variation may be unknown constituents, constituents with unknown concentrations, nonlinear responses, non-uniform and correlated errors, or other sources of spectral variation that are present in the calibration sample spectra. Also, since the various ACLS methods are based on CLS, they can incorporate the new prediction-augmented CLS (PACLS) method of updating the prediction model for new sources of spectral variation contained in the prediction sample set without having to return to the calibration process. The ACLS methods can also be applied to alternating least squares models. The ACLS methods can be applied to all types of multivariate data.
NASA Astrophysics Data System (ADS)
Leroi, Vaitua; Bibring, Jean-Pierre; Berthe, Michel
2009-07-01
MicrOmega is an ultra miniaturized spectral microscope for in situ analysis of samples. It is composed of 2 microscopes; one with a spatial sampling less or equal to 4 μm, working in 4 colors in the visible range: MicrOmega/VIS, and a NIR hyperspectral microscope working in the spectral range 0.9-4 μm with a spatial sampling of 20 μm per pixel: MicrOmega/IR (described in this paper). MicrOmega/IR illuminates and images samples a few mm in size and acquires the NIR spectrum of each resolved pixel in up to 320 contiguous spectral channels. The goal of this instrument is to analyze in situ the composition of collected samples at almost their grain size scale, in a non-destructive way. With the chosen spectral range and resolution, a wide variety of constituents can be identified: minerals, such as pyroxene and olivine, ferric oxides, hydrated phyllosilicates, sulfates and carbonates and ices and organics. The composition of the various phases within a given sample is a critical record of its formation and evolution. Coupled to the mapping information, it provides unique clues to describe the history of the parent body (planet, satellite and small body). In particular, the capability to identify hydrated grains and to characterize their adjacent phases has a huge potential in the search for possible bio-relics.
NASA Technical Reports Server (NTRS)
Susskind, Joel; Iredell, Lena
2010-01-01
AIRS (Atmospheric Infra-Red Sounder), was launched, in conjunction with AMSU-A (Advanced Microwave Sounding Unit-A) on the NASA polar orbiting research satellite EOS (Earth Observing System) Aqua satellite in May 2002 as a next generation atmospheric sounding system. Atmospheric sounders provide information primarily about the vertical distribution of atmospheric temperature and water vapor distribution. This is achieved by measuring outgoing radiation in discrete channels (spectral intervals) which are sensitive primarily to variations of these geophysical parameters. The primary objectives of AIRS/AMSU were to utilize such information in order to improve the skill of numerical weather prediction as well as to measure climate variability and trends. AIRS is a multi-detector array grating spectrometer with 2378 channels covering the spectral range 650/cm (15 microns) to 2660/cm (3.6 microns) with a resolving power (i/a i) of roughly 1200 where a i is the spectral channel bandpass. Atmospheric temperature profile can be determined from channel observations taken within the 15 micron (the long-wave CO2 absorption band) and within the 4.2 micron (the short-wave CO2 absorption band). Radiances in these (and all other) spectral intervals in the infrared are also sensitive to the presence of clouds in the instrument?s field of view (FOV), which are present about 95% of the time. AIRS was designed so as to allow for the ability to produce accurate Quality Controlled atmospheric soundings under most cloud conditions. This was achieved by having 1) extremely low channel noise values in the shortwave portion of the spectrum and 2) a very flat spatial response function within a channel?s FOV. IASI, the high spectral resolution IR interferometer flying on the European METOP satellite, does not contain either of these important characteristics. The AIRS instrument was also designed to be extremely stabile with regard to its spectral radiometric characteristics, which is critical with regard to the ability to measure accurate long term trends.
Study of RCR Catalogue Radio Source Integral Spectra
NASA Astrophysics Data System (ADS)
Zhelenkova, O. P.; Majorova, E. K.
2018-04-01
We present the characteristics of the sources found on the averaged scans of the "Cold" experiment 1980-1999 surveys in the right-ascension interval 2h< RA < 7h. Thereby, a refinement of the parameters of the RC catalog sources (RATANCold) for this interval is complete. To date, the RCR catalog (RATAN Cold Refined) covers the right-ascension interval 2h< RA < 17h and includes 830 sources. The spectra are built for them with the use of new data in the range of 70-230 MHz. The dependence between the spectral indices α 0.5, α 3.94 and integral flux density at the frequencies of 74 and 150 MHz, at 1.4, 3.94 and 4.85 GHz is discussed.We found that at 150 MHz in most sources the spectral index α 0.5 gets steeper with increasing flux density. In general, the sources with flat spectra are weaker in terms of flux density than the sources with steep spectra, which especially differs at 150 MHz. We believe that this is due to the brightness of their extended components, which can be determined by the type of accretion and the neighborhood of the source.
[Building Mass Spectrometry Spectral Libraries of Human Cancer Cell Lines].
Faktor, J; Bouchal, P
Cancer research often focuses on protein quantification in model cancer cell lines and cancer tissues. SWATH (sequential windowed acquisition of all theoretical fragment ion spectra), the state of the art method, enables the quantification of all proteins included in spectral library. Spectral library contains fragmentation patterns of each detectable protein in a sample. Thorough spectral library preparation will improve quantitation of low abundant proteins which usually play an important role in cancer. Our research is focused on the optimization of spectral library preparation aimed at maximizing the number of identified proteins in MCF-7 breast cancer cell line. First, we optimized the sample preparation prior entering the mass spectrometer. We examined the effects of lysis buffer composition, peptide dissolution protocol and the material of sample vial on the number of proteins identified in spectral library. Next, we optimized mass spectrometry (MS) method for spectral library data acquisition. Our thorough optimized protocol for spectral library building enabled the identification of 1,653 proteins (FDR < 1%) in 1 µg of MCF-7 lysate. This work contributed to the enhancement of protein coverage in SWATH digital biobanks which enable quantification of arbitrary protein from physically unavailable samples. In future, high quality spectral libraries could play a key role in preparing of patient proteome digital fingerprints.Key words: biomarker - mass spectrometry - proteomics - digital biobanking - SWATH - protein quantificationThis work was supported by the project MEYS - NPS I - LO1413.The authors declare they have no potential conflicts of interest concerning drugs, products, or services used in the study.The Editorial Board declares that the manuscript met the ICMJE recommendation for biomedical papers.Submitted: 7. 5. 2016Accepted: 9. 6. 2016.
NASA Astrophysics Data System (ADS)
Fu, Yan; Guo, Pei-yuan; Xiang, Ling-zi; Bao, Man; Chen, Xing-hai
2013-08-01
With the gradually mature of hyper spectral image technology, the application of the meat nondestructive detection and recognition has become one of the current research focuses. This paper for the study of marine and freshwater fish by the pre-processing and feature extraction of the collected spectral curve data, combined with BP network structure and LVQ network structure, a predictive model of hyper spectral image data of marine and freshwater fish has been initially established and finally realized the qualitative analysis and identification of marine and freshwater fish quality. The results of this study show that hyper spectral imaging technology combined with the BP and LVQ Artificial Neural Network Model can be used for the identification of marine and freshwater fish detection. Hyper-spectral data acquisition can be carried out without any pretreatment of the samples, thus hyper-spectral imaging technique is the lossless, high- accuracy and rapid detection method for quality of fish. In this study, only 30 samples are used for the exploratory qualitative identification of research, although the ideal study results are achieved, we will further increase the sample capacity to take the analysis of quantitative identification and verify the feasibility of this theory.
Pavithran, Purushothaman; Prakash, E Sankaranarayanan; Dutta, Tarun K; Madanmohan, Trakroo
2010-02-01
1. Abnormalities of cardiac autonomic regulation are a potential mechanism for morbidity despite blood pressure (BP) lowering in hypertension. Analysis of short-term (5 min) heart rate variability (HRV) provides a non-invasive probe of autonomic regulation of sino-atrial (SA) node automaticity. 2. We hypothesized that antihypertensive drug therapy would be associated with an increase in 5 min overall HRV, along with a decrease in blood pressure (BP), at 8 weeks follow up in subjects with newly diagnosed, never-treated essential hypertension. 3. One hundred and fifty patients (84 men and 66 women; mean (+/-SD) age 48 +/- 10 years) with newly diagnosed essential hypertension were divided to five groups of 30 patients each to receive one of the following antihypertensive drugs (or drug combinations): 5 mg/day amlodipine; 50 mg/day atenolol; 5 mg/day enalapril; 25 mg/day hydrochlorothiazide; or a combination of 5 mg/day amlodipine and 50 mg/day atenolol. 4. The only significant change in HRV indices was an increase in total variability of RR intervals and an increase in high-frequency (HF) RR interval spectral power in the amlodipine + atenolol-treated group (P < 0.05). 5. The results indicate that there is a dissociation between changes in short-term HRV and mean RR interval and BP lowering in patients with newly diagnosed hypertension. 6. We interpret the increase in HF RR interval spectral power in the amlodipine + atenolol-treated group as being due to an increase in vagal modulation of RR intervals and/or diminution in sympathetic restraint of respiratory sinus arrhythmia.
Myoeletric indices of fatigue adopting different rest intervals during leg press sets.
Miranda, Humberto; Maia, Marianna; de Oliveira, Carlos G; Farias, Déborah; da Silva, Jurandir B; Lima, Vicente P; Willardson, Jeffrey M; Paz, Gabriel A
2018-01-01
The purpose of this study was to examine the acute effect of different rest intervals between multiple sets of the 45° angled leg press exercise (LP45) on surface electromyographic (SEMG) spectral and amplitude indices of fatigue. Fifteen recreationally trained females performed three protocols in a randomized crossover design; each consisting of four sets of 10 repetitions with 1 (P1), 3 (P3), or 5 (P5) minute rest intervals between sets. Each set was performed with 70% of the LP45 ten-repetition maximum load. The SEMG data for biceps femoris (BF), vastus lateralis (VL), vastus medialis (VM), and rectus femoris (RF) muscles was then evaluated. The SEMG amplitude change in the time coefficient (CRMS) and spectral fatigue index (Cf5) indicated higher levels of fatigue for all muscles evaluated during the P3 protocol versus the P1 and P5 protocols (p ≤ 0.05), respectively. The RF and VL muscles showed greater fatigue levels by the second and third sets; whereas, greater fatigue was shown in the VM and BF muscles by the fourth set (p ≤ 0.05). A three-minute rest interval between sets might represent a neuromuscular window between a fatigue stated and fully recovered state in the context of neural activation. Moreover, a three minute rest interval between sets might allow for consistent recruitment of high threshold motor units over multiple sets, and thus promote a more effective stimulus for strength gains. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Liu, Xudong; Zeng, Bingfang; Fan, Cunyi; Jiang, Peizhu; Hu, Xiao
2006-01-01
To find the properties in the oscillatory components of the cutaneous blood flow on the successful free flap, a wavelet transform was applied to the laser Doppler flowmetry (LDF) signals which were measured simultaneously on the surfaces of the free latissimus dorsi myocutaneous flap and on the adjacent intact skin of the healthy limb, of 18 patients. The frequency interval from 0.0095 to 1.6 Hz was examined and was divided into five subintervals (I: 0.0095-0.021 Hz; II: 0.021-0.052 Hz; III: 0.052-0.145 Hz; IV: 0.145-0.6 Hz and V: 0.6-1.6 Hz) corresponding to endothelial metabolic, neurogenic, myogenic, respiratory and cardiac origins. The average amplitude and total power in the frequency range 0.0095-1.6 Hz as well as within subintervals I, II, IV and V were significantly lower for signals measured on the free flap than those obtained in the healthy limb. However in interval III, they were significantly higher. The normalized spectral amplitude and power in the free flap were significantly lower in only two intervals, I and II, yet in interval III they were significantly higher; no statistical significance was observed in intervals IV and V. The distinctive finding made in this study, aside from the decrease of endothelial metabolic processes and sympathetic control, was the significant increase of myogenic activity in the free flap. It is hoped that this work will contribute towards knowledge on blood circulation in free flaps and make the monitoring by LDF more reliable.
FTIR-ATR infrared spectroscopy for the detection of ochratoxin A in dried vine fruit.
Galvis-Sánchez, Andrea C; Barros, Antonio; Delgadillo, Ivonne
2007-11-01
A method of screening sultanas for ochratoxin A (OTA) contamination, using mid-infrared spectroscopy/Golden Gate single-reflection ATR (attenuated total reflection), is described. The main spectral characteristics of sultanas from different sources were identified in a preliminary acquisition and spectral analysis study. Principal component analysis (PCA) showed that samples of various origins had different spectral characteristics, especially in water content and the fingerprint region. A lack of reproducibility was observed in the spectra acquired on different days. However, spectral repeatability was greatly improved when water activity of the sample was set at 0.62. A calibration curve of OTA was constructed in the range 10-40 microg OTA kg(-1). Samples with OTA levels higher than 20 microg kg(-1) were separated from samples contaminated with a lower concentration (10 microg OTA kg(-1)) and from uncontaminated samples. The reported methodology is a reliable and simple technique for screening dried vine fruit for OTA.
USGS Digital Spectral Library splib06a
Clark, Roger N.; Swayze, Gregg A.; Wise, Richard A.; Livo, K. Eric; Hoefen, Todd M.; Kokaly, Raymond F.; Sutley, Stephen J.
2007-01-01
Introduction We have assembled a digital reflectance spectral library that covers the wavelength range from the ultraviolet to far infrared along with sample documentation. The library includes samples of minerals, rocks, soils, physically constructed as well as mathematically computed mixtures, plants, vegetation communities, microorganisms, and man-made materials. The samples and spectra collected were assembled for the purpose of using spectral features for the remote detection of these and similar materials. Analysis of spectroscopic data from laboratory, aircraft, and spacecraft instrumentation requires a knowledge base. The spectral library discussed here forms a knowledge base for the spectroscopy of minerals and related materials of importance to a variety of research programs being conducted at the U.S. Geological Survey. Much of this library grew out of the need for spectra to support imaging spectroscopy studies of the Earth and planets. Imaging spectrometers, such as the National Aeronautics and Space Administration (NASA) Airborne Visible/Infra Red Imaging Spectrometer (AVIRIS) or the NASA Cassini Visual and Infrared Mapping Spectrometer (VIMS) which is currently orbiting Saturn, have narrow bandwidths in many contiguous spectral channels that permit accurate definition of absorption features in spectra from a variety of materials. Identification of materials from such data requires a comprehensive spectral library of minerals, vegetation, man-made materials, and other subjects in the scene. Our research involves the use of the spectral library to identify the components in a spectrum of an unknown. Therefore, the quality of the library must be very good. However, the quality required in a spectral library to successfully perform an investigation depends on the scientific questions to be answered and the type of algorithms to be used. For example, to map a mineral using imaging spectroscopy and the mapping algorithm of Clark and others (1990a, 2003b), one simply needs a diagnostic absorption band. The mapping system uses continuum-removed reference spectral features fitted to features in observed spectra. Spectral features for such algorithms can be obtained from a spectrum of a sample containing large amounts of contaminants, including those that add other spectral features, as long as the shape of the diagnostic feature of interest is not modified. If, however, the data are needed for radiative transfer models to derive mineral abundances from reflectance spectra, then completely uncontaminated spectra are required. This library contains spectra that span a range of quality, with purity indicators to flag spectra for (or against) particular uses. Acquiring spectral measurements and performing sample characterizations for this library has taken about 15 person-years of effort. Software to manage the library and provide scientific analysis capability is provided (Clark, 1980, 1993). A personal computer (PC) reader for the library is also available (Livo and others, 1993). The program reads specpr binary files (Clark, 1980, 1993) and plots spectra. Another program that reads the specpr format is written in IDL (Kokaly, 2005). In our view, an ideal spectral library consists of samples covering a very wide range of materials, has large wavelength range with very high precision, and has enough sample analyses and documentation to establish the quality of the spectra. Time and available resources limit what can be achieved. Ideally, for each mineral, the sample analysis would include X-ray diffraction (XRD), electron microprobe (EM) or X-ray fluorescence (XRF), and petrographic microscopic analyses. For some minerals, such as iron oxides, additional analyses such as Mossbauer would be helpful. We have found that to make the basic spectral measurements, provide XRD, EM or XRF analyses, and microscopic analyses, document the results, and complete an entry of one spectral library sample, all takes about
Directional optical transmission through a sand layer: a preliminary laboratory experiment
NASA Astrophysics Data System (ADS)
Tian, Jia; Philpot, William D.
2017-10-01
Given the importance of penetration of light in the soil for seed germination, soil warming, and the photolytic degradation of pesticides, directional transmission of thin sand samples are studied in this paper under both dry and saturated conditions. The detector views upward through a glass-bottom sample holder, filled to 3 or 4 mm with a coarse, translucent, quartz sand sample. Transmission through the samples was measured as the illumination zenith angle moved from 0 to 70° in 5° intervals. In the most cases, transmission decreased monotonically, but slowly with increasing illumination angle at all wavelengths. A peak in transmission only appeared at 0° illumination for the low bulk density, dry sample at 3 mm depth. The 0° peak disappeared when the sample was wetted, when the bulk density increased, or when the depth of the sample increased, which indicates that the radiation transmitting through a sand layer can be diffused thoroughly with a millimeters-thin sand layer. For the saturated samples, water influences light transmission in contrasting ways in shorter and longer wavelength. Transmission increased in the VNIR when saturated relative to dry, while transmission decreased sharply after 1300 nm, with spectral absorption features characteristic of water absorption. In VNIR region, water absorption is low and the low relative index of refraction enhanced transmission through sand sample. In contrast, water absorption became dominant at longer wavelengths region leading to the strongly reduced transmission.
Differential Go/NoGo Activity in Both Contingent Negative Variation and Spectral Power
Funderud, Ingrid; Lindgren, Magnus; Løvstad, Marianne; Endestad, Tor; Voytek, Bradley; Knight, Robert T.; Solbakk, Anne-Kristin
2012-01-01
We investigated whether both the contingent negative variation (CNV), an event-related potential index of preparatory brain activity, and event-related oscillatory EEG activity differentiated Go and NoGo trials in a delayed response task. CNV and spectral power (4–100 Hz) were calculated from EEG activity in the preparatory interval in 16 healthy adult participants. As previously reported, CNV amplitudes were higher in Go compared to NoGo trials. In addition, event-related spectral power of the Go condition was reduced in the theta to low gamma range compared to the NoGo condition, confirming that preparing to respond is associated with modulation of event-related spectral activity as well as the CNV. Altogether, the impact of the experimental manipulation on both slow event-related potentials and oscillatory EEG activity may reflect coordinated dynamic changes in the excitability of distributed neural networks involved in preparation. PMID:23119040
Rocket studies of solar corona and transition region. [X-Ray spectrometer/spectrograph telescope
NASA Technical Reports Server (NTRS)
Acton, L. W.; Bruner, E. C., Jr.; Brown, W. A.; Nobles, R. A.
1979-01-01
The XSST (X-Ray Spectrometer/Spectrograph Telescope) rocket payload launched by a Nike Boosted Black Brant was designed to provide high spectral resolution coronal soft X-ray line information on a spectrographic plate, as well as time resolved photo-electric records of pre-selected lines and spectral regions. This spectral data is obtained from a 1 x 10 arc second solar region defined by the paraboloidal telescope of the XSST. The transition region camera provided full disc images in selected spectral intervals originating in lower temperature zones than the emitting regions accessible to the XSST. A H-alpha camera system allowed referencing the measurements to the chromospheric temperatures and altitudes. Payload flight and recovery information is provided along with X-ray photoelectric and UV flight data, transition camera results and a summary of the anomalies encountered. Instrument mechanical stability and spectrometer pointing direction are also examined.
NASA Astrophysics Data System (ADS)
Heap, Sara
2009-07-01
Hubble's Next Generation Spectral Library {NGSL} comprises intermediate-resolution {R 1000} STIS spectra of 378 stars having a wide range in metallicity and age. Unique features of the NGSL include its broad wavelength coverage {1,800-10,100 ?} and high-S/N, absolute spectrophotometry. When incorporated in modern stellar population synthesis codes, the NGSL should enable us to constrain simultaneously the star-formation history and metal-enrichment history of galaxies over a wide redshift interval {z= 0-2}. In AR10659, we laid the foundation for tracing the spectral evolution of galaxies by putting the NGSL in order. We now propose to derive the atmospheric and fundamental parameters of the program stars, generate integrated spectra of stellar populations of different metallicities and initial mass functions, and derive spectral diagnostics of the age, metalllicity and E{B-V} of stellar populations.
NASA Technical Reports Server (NTRS)
Fymat, A. L.; Mease, K. D.
1978-01-01
The technique proposed by Fymat (1976) for retrieving the complex refractive index of atmospheric aerosols using narrowband spectral transmission ratios, taken within an overall narrow spectral interval, is investigated in the case of modelled polydispersions of rural, maritime-continental, maritime-sea spray and meteoric dust aerosols. It is confirmed that for not too broad size distributions most of the information comes from a narrow size range of 'active' aerosols so that, under these circumstances, the refractive index components can indeed be retrieved essentially independently of the size distribution. For 0.1% accurate data in three colors, the technique can provide the real and imaginary components of the index respectively within 0.07% and 0.3% accuracy.
Laboratory Thermal Infrared and Visible to Near-Infrared Spectral Analysis of Chert
NASA Astrophysics Data System (ADS)
McDowell, M. L.; Hamilton, V. E.
2007-12-01
Though basaltic materials dominate the composition of the Martian surface, a material with a relatively high silica component in an area of Eos Chasma was reported by [1] from thermal infrared (TIR) data. The spectrum of the silica phase resembles quartz or chert, but with the existing information it is difficult to tell which phase best fits the observations. Though quartz, chert, and amorphous silica are chemically identical (SiO2), their physical differences (e.g., microstructures) result in different TIR spectral characteristics. Previous studies have analyzed a limited number of chert samples using emission infrared spectroscopy [2] and transmission infrared spectroscopy [3]. We continue these preliminary studies with an investigation aiming to more completely understand and document the variation in spectral character of cherts. This knowledge may help to identify the silica phase in Eos Chasma and any future discoveries. Our study includes a more extensive sampling of geologic chert in hand sample (>15 samples) with various sources, methods of formation, surface textures, and crystallinities. We analyzed their visible to near-infrared (VNIR) reflectance spectra, as well as spectral features in TIR emission spectra. We measured multiple locations on each sample to determine spectral homogeneity across the sample and between various orientations. Where possible, natural, cut, and recently fractured surfaces were measured. We compared the collected TIR spectra for similarities and differences in shape and spectral contrast within each sample and between samples that may relate to variations in the samples' structure (e.g. crystallinity, and surface texture). VNIR measurements show features indicative of non-silica phases and water that may be present in the cherts. [1] Hamilton, V.E. (2005) Eos Trans. AGU, Fall Meeting Suppl., Abstract P24A-08. [2] Michalski, J.R. (2005) PhD Diss., ASU, Tempe. [3] Long, D. G. et al. (2001) Canadian Archaeological Assoc., 33rd Meeting.
Scanner observations of cool stars from 3400 to 11,000 A.
NASA Technical Reports Server (NTRS)
Fay, T.; Honeycutt, R. K.
1972-01-01
Evaluation of photoelectric scans of the M supergiant alpha Ori and the carbon stars 19 Psc, W Ori, and DS Peg made at 20-A resolution from 3400 to 6000 A and at 40-A resolution from 6000 to 11,000 A. The data are corrected for atmospheric extinction and for the instrumental response to obtain plots of log flux per unit frequency interval versus wavelength. The dominant spectral features are due to C2, CN, and TiO; the variation of these features with spectral class is pointed out.
NASA Astrophysics Data System (ADS)
Santoyo, A. T.; Shlyagin, M. G.; Mendieta, F. J.; Spirin, V.; de Rivera, L. N.
2005-12-01
We develop an analysis of the behavior of an evanescent field fiber optic sensor under different conditions for its optimization. This paper presents results of an experimental study of the spectral characteristics of a polymer cladding optical fiber exposed to different analytes. The measurements were performed in the spectral interval from 1100 to 1800 nanometers in a temperature range from 5 to 50 degrees C. Influence of ambient temperature on the optical fiber transmittance was found to be strongly dependent on wavelength.
NASA Astrophysics Data System (ADS)
Snow, M. A.; Machol, J. L.; Richard, E. C.
2016-12-01
Solar spectral irradiance (SSI) has been measured since the beginning of the satellite era in 1978, but the observational record has many gaps in both wavelength and time. We describe our current effort in linking several such datasets ranging from the Extreme Ultraviolet to the Near Ultraviolet (0-400 nm). This wavelength range includes two important solar activity proxies, the Magnesium II core—to-wing ratio and the Lyman alpha irradiance, and special attention will be applied to these two wavelength intervals.
Drill hole logging with infrared spectroscopy
Calvin, W.M.; Solum, J.G.
2005-01-01
Infrared spectroscopy has been used to identify rocks and minerals for over 40 years. The technique is sensitive to primary silicates as well as alteration products. Minerals can be uniquely identified based on multiple absorption features at wavelengths from the visible to the thermal infrared. We are currently establishing methods and protocols in order to use the technique for rapid assessment of downhole lithology on samples obtained during drilling operations. Initial work performed includes spectral analysis of chip cuttings and core sections from drill sites around Desert Peak, NV. In this paper, we report on a survey of 10,000 feet of drill cuttings, at 100 foot intervals, from the San Andreas Fault Observatory at Depth (SAFOD). Data from Blue Mountain geothermal wells will also be acquired. We will describe the utility of the technique for rapid assessment of lithologic and mineralogic discrimination.
NASA Technical Reports Server (NTRS)
Gatebe, Charles K.; King, M. D.; Arnold, G. T.; Li, J. Y.; Lau, William K. M. (Technical Monitor)
2001-01-01
The Cloud Absorption Radiometer (CAR) was flown aboard the University of Washington Convair CV-580 research aircraft and took measurements on 23 flights between August 15 and September 16. On 12 of those flights, BRF measurements were obtained over different natural surfaces and ecosystem in southern Africa. The BRF measurements were done to characterize surface anisotropy in support of SAFARI 2000 science objectives principally to validate products from NASA's EOS satellites, and to parameterize and validate BRF models. In this paper we present results of BRFs taken over two EOS validation sites: Skukuza tower, South Africa (25.0 deg S, 31.5 deg E) and Mongu tower, Zambia (15.4 deg S, 23.3 deg E). Additional sites are also considered and include, Maun tower, Botswana (20.0 deg S, 23.5 deg E), Sowa Pan, Botswana (20.6 deg S, 26.2 deg E) and Etosha Pan, Namibia (19.0 deg S, 16.0 deg E). The CAR is capable of measuring scattered light in fourteen spectral bands. The scan mirror, rotating at 100 rpm, directs the light into a Dall-Kirkham telescope where the beam is split into nine paths. Eight light beams pass through beam splitters, dichroics, and lenses to individual detectors (0.34-1.27 micrometers), and finally are registered by eight data channels. They are sampled simultaneously and continuously. The ninth beam passes through a spinning filter wheel to an InSb detector cooled by a Stirling cycle cooler. Signals registered by the ninth data channel are selected from among six spectral channels (1.55-2.30 micrometers). The filter wheel can either cycle through all six spectral bands at a prescribed interval (usually changing filter every fifth scan line), or lock onto any one of the six spectral bands and sample it continuously. To measure the BRF of the surface-atmosphere system, the University of Washington CV-580 had to bank at a comfortable roll angle of approximately 20 degrees and fly in a circle about 3 km in diameter above the surface for roughly two minutes. Replicated observations (multiple circular orbits) were acquired over selected surfaces so that average BRF smooth out small-scale surface and atmospheric inhomogeneities. At an altitude of 600 m above the targeted surface area and with a 1 deg IFOV, the pixel resolution is about 10 m at nadir and about 270 m at an 80 deg viewing angle from the CAR.
Spectral Characterization of Analog Samples in Anticipation of OSIRIS-REx's Arrival at Bennu
NASA Technical Reports Server (NTRS)
Donaldson Hanna, K. L.; Schrader, D. L.; Bowles, N. E.; Clark, B. E.; Cloutis, E. A.; Connolly, H. C., Jr.; Hamilton, V. E.; Keller, L. P.; Lauretta, D. S.; Lim, L. F.;
2017-01-01
NASA's Origins, Spectral Interpretation, Resource Identification, and Security-Regolith Explorer (OSIRIS-REx) mission successfully launched on September 8th, 2016. During its rendezvous with near-Earth asteroid (101955) Bennu beginning in 2018, OSIRIS-REx will characterize the asteroid's physical, mineralogical, and chemical properties in an effort to globally map the properties of Bennu, a primitive carbonaceous asteroid, and choose a sampling location]. In preparation for these observations, analog samples were spectrally characterized across visible, near- and thermal-infrared wavelengths and were used in initial tests on mineral-phase-detection and abundance-determination software algorithms.
On-line measurement of lignin in wood pulp by color shift of fluorescence
Jeffers, Larry A.; Malito, Michael L.
1996-01-01
Lignin concentrations from wood pulp samples are measured by applying an excitation light at a selected wavelength to the samples in order to cause the lignin to emit fluorescence. A spectral distribution of the fluorescence emission is then determined. The lignin concentration is then calculated based on the spectral distribution signal. The spectral distribution is quantified by either a wavelength centroid method or a band ratio method.
On-line measurement of lignin in wood pulp by color shift of fluorescence
Jeffers, L.A.; Malito, M.L.
1996-01-23
Lignin concentrations from wood pulp samples are measured by applying an excitation light at a selected wavelength to the samples in order to cause the lignin to emit fluorescence. A spectral distribution of the fluorescence emission is then determined. The lignin concentration is then calculated based on the spectral distribution signal. The spectral distribution is quantified by either a wavelength centroid method or a band ratio method. 6 figs.
Variation of surface water spectral response as a function of in situ sampling technique
NASA Technical Reports Server (NTRS)
Davis, Bruce A.; Hodgson, Michael E.
1988-01-01
Tests were carried out to determine the spectral variation contributed by a particular sampling technique. A portable radiometer was used to measure the surface water spectral response. Variation due to the reflectance of objects near the radiometer (i.e., the boat side) during data acquisition was studied. Consideration was also given to the variation due to the temporal nature of the phenomena (i.e., wave activity).
NASA Technical Reports Server (NTRS)
Taylor, J. A.; Myers, C. W.; Halliwill, J. R.; Seidel, H.; Eckberg, D. L.
2001-01-01
Clinicians and experimentalists routinely estimate vagal-cardiac nerve traffic from respiratory sinus arrhythmia. However, evidence suggests that sympathetic mechanisms may also modulate respiratory sinus arrhythmia. Our study examined modulation of respiratory sinus arrhythmia by sympathetic outflow. We measured R-R interval spectral power in 10 volunteers that breathed sequentially at 13 frequencies, from 15 to 3 breaths/min, before and after beta-adrenergic blockade. We fitted changes of respiratory frequency R-R interval spectral power with a damped oscillator model: frequency-dependent oscillations with a resonant frequency, generated by driving forces and modified by damping influences. beta-Adrenergic blockade enhanced respiratory sinus arrhythmia at all frequencies (at some, fourfold). The damped oscillator model fit experimental data well (39 of 40 ramps; r = 0.86 +/- 0.02). beta-Adrenergic blockade increased respiratory sinus arrhythmia by amplifying respiration-related driving forces (P < 0.05), without altering resonant frequency or damping influences. Both spectral power data and the damped oscillator model indicate that cardiac sympathetic outflow markedly reduces heart period oscillations at all frequencies. This challenges the notion that respiratory sinus arrhythmia is mediated simply by vagal-cardiac nerve activity. These results have important implications for clinical and experimental estimation of human vagal cardiac tone.
Ropodi, Athina I; Panagou, Efstathios Z; Nychas, George-John E
2018-01-01
In recent years, fraud detection has become a major priority for food authorities, as fraudulent practices can have various economic and safety consequences. This work explores ways of identifying frozen-then-thawed minced beef labeled as fresh in a rapid, large-scale and cost-effective way. For this reason, freshly-ground beef was purchased from seven separate shops at different times, divided in fifteen portions and placed in Petri dishes. Multi-spectral images and FTIR spectra of the first five were immediately acquired while the remaining were frozen (-20°C) and stored for 7 and 32days (5 samples for each time interval). Samples were thawed and subsequently subjected to similar data acquisition. In total, 105 multispectral images and FTIR spectra were collected which were further analyzed using partial least-squares discriminant analysis and support vector machines. Two meat batches (30 samples) were reserved for independent validation and the remaining five batches were divided in training and test set (75 samples). Results showed 100% overall correct classification for test and external validation MSI data, while FTIR data yielded 93.3 and 96.7% overall correct classification for FTIR test set and external validation set respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.
Measurement of high-temperature spectral emissivity using integral blackbody approach
NASA Astrophysics Data System (ADS)
Pan, Yijie; Dong, Wei; Lin, Hong; Yuan, Zundong; Bloembergen, Pieter
2016-11-01
Spectral emissivity is one of the most critical thermophysical properties of a material for heat design and analysis. Especially in the traditional radiation thermometry, normal spectral emissivity is very important. We developed a prototype instrument based upon an integral blackbody method to measure material's spectral emissivity at elevated temperatures. An optimized commercial variable-high-temperature blackbody, a high speed linear actuator, a linear pyrometer, and an in-house designed synchronization circuit was used to implemented the system. A sample was placed in a crucible at the bottom of the blackbody furnace, by which the sample and the tube formed a simulated reference blackbody which had an effective total emissivity greater than 0.985. During the measurement, a pneumatic cylinder pushed a graphite rode and then the sample crucible to the cold opening within hundreds of microseconds. The linear pyrometer was used to monitor the brightness temperature of the sample surface, and the corresponding opto-converted voltage was fed and recorded by a digital multimeter. To evaluate the temperature drop of the sample along the pushing process, a physical model was proposed. The tube was discretized into several isothermal cylindrical rings, and the temperature of each ring was measurement. View factors between sample and rings were utilized. Then, the actual surface temperature of the sample at the end opening was obtained. Taking advantages of the above measured voltage signal and the calculated actual temperature, normal spectral emissivity under the that temperature point was obtained. Graphite sample at 1300°C was measured to prove the validity of the method.
Identification of mineral compositions in some renal calculi by FT Raman and IR spectral analysis
NASA Astrophysics Data System (ADS)
Tonannavar, J.; Deshpande, Gouri; Yenagi, Jayashree; Patil, Siddanagouda B.; Patil, Nikhil A.; Mulimani, B. G.
2016-02-01
We present in this paper accurate and reliable Raman and IR spectral identification of mineral constituents in nine samples of renal calculi (kidney stones) removed from patients suffering from nephrolithiasis. The identified mineral components include Calcium Oxalate Monohydrate (COM, whewellite), Calcium Oxalate Dihydrate (COD, weddellite), Magnesium Ammonium Phosphate Hexahydrate (MAPH, struvite), Calcium Hydrogen Phosphate Dihydrate (CHPD, brushite), Pentacalcium Hydroxy Triphosphate (PCHT, hydroxyapatite) and Uric Acid (UA). The identification is based on a satisfactory assignment of all the observed IR and Raman bands (3500-400 cm- 1) to chemical functional groups of mineral components in the samples, aided by spectral analysis of pure materials of COM, MAPH, CHPD and UA. It is found that the eight samples are composed of COM as the common component, the other mineral species as common components are: MAPH in five samples, PCHT in three samples, COD in three samples, UA in three samples and CHPD in two samples. One sample is wholly composed of UA as a single component; this inference is supported by the good agreement between ab initio density functional theoretical spectra and experimental spectral measurements of both sample and pure material. A combined application of Raman and IR techniques has shown that, where the IR is ambiguous, the Raman analysis can differentiate COD from COM and PCHT from MAPH.
Identification of mineral compositions in some renal calculi by FT Raman and IR spectral analysis.
Tonannavar, J; Deshpande, Gouri; Yenagi, Jayashree; Patil, Siddanagouda B; Patil, Nikhil A; Mulimani, B G
2016-02-05
We present in this paper accurate and reliable Raman and IR spectral identification of mineral constituents in nine samples of renal calculi (kidney stones) removed from patients suffering from nephrolithiasis. The identified mineral components include Calcium Oxalate Monohydrate (COM, whewellite), Calcium Oxalate Dihydrate (COD, weddellite), Magnesium Ammonium Phosphate Hexahydrate (MAPH, struvite), Calcium Hydrogen Phosphate Dihydrate (CHPD, brushite), Pentacalcium Hydroxy Triphosphate (PCHT, hydroxyapatite) and Uric Acid (UA). The identification is based on a satisfactory assignment of all the observed IR and Raman bands (3500-400c m(-1)) to chemical functional groups of mineral components in the samples, aided by spectral analysis of pure materials of COM, MAPH, CHPD and UA. It is found that the eight samples are composed of COM as the common component, the other mineral species as common components are: MAPH in five samples, PCHT in three samples, COD in three samples, UA in three samples and CHPD in two samples. One sample is wholly composed of UA as a single component; this inference is supported by the good agreement between ab initio density functional theoretical spectra and experimental spectral measurements of both sample and pure material. A combined application of Raman and IR techniques has shown that, where the IR is ambiguous, the Raman analysis can differentiate COD from COM and PCHT from MAPH. Copyright © 2015 Elsevier B.V. All rights reserved.
Relation of laboratory and remotely sensed spectral signatures of ocean-dumped acid waste
NASA Technical Reports Server (NTRS)
Lewis, B. W.
1978-01-01
Results of laboratory transmission and remotely sensed ocean upwelled spectral signatures of acid waste ocean water solutions are presented. The studies were performed to establish ocean-dumped acid waste spectral signatures and to relate them to chemical and physical interactions occurring in the dump plume. The remotely sensed field measurements and the laboratory measurements were made using the same rapid-scanning spectrometer viewing a dump plume and with actual acid waste and ocean water samples, respectively. Laboratory studies showed that the signatures were produced by soluble ferric iron being precipitated in situ as ferric hydroxide upon dilution with ocean water. Sea-truth water samples were taken and analyzed for pertinent major components of the acid waste. Relationships were developed between the field and laboratory data both for spectral signatures and color changes with concentration. The relationships allow for the estimation of concentration of the indicator iron from remotely sensed spectral data and the laboratory transmission concentration data without sea-truth samples.
GEOS-2 C-band radar system project. Spectral analysis as related to C-band radar data analysis
NASA Technical Reports Server (NTRS)
1972-01-01
Work performed on spectral analysis of data from the C-band radars tracking GEOS-2 and on the development of a data compaction method for the GEOS-2 C-band radar data is described. The purposes of the spectral analysis study were to determine the optimum data recording and sampling rates for C-band radar data and to determine the optimum method of filtering and smoothing the data. The optimum data recording and sampling rate is defined as the rate which includes an optimum compromise between serial correlation and the effects of frequency folding. The goal in development of a data compaction method was to reduce to a minimum the amount of data stored, while maintaining all of the statistical information content of the non-compacted data. A digital computer program for computing estimates of the power spectral density function of sampled data was used to perform the spectral analysis study.
Wavelength Scanning with a Tilting Interference Filter for Glow-Discharge Elemental Imaging.
Storey, Andrew P; Ray, Steven J; Hoffmann, Volker; Voronov, Maxim; Engelhard, Carsten; Buscher, Wolfgang; Hieftje, Gary M
2017-06-01
Glow discharges have long been used for depth profiling and bulk analysis of solid samples. In addition, over the past decade, several methods of obtaining lateral surface elemental distributions have been introduced, each with its own strengths and weaknesses. Challenges for each of these techniques are acceptable optical throughput and added instrumental complexity. Here, these problems are addressed with a tilting-filter instrument. A pulsed glow discharge is coupled to an optical system comprising an adjustable-angle tilting filter, collimating and imaging lenses, and a gated, intensified charge-coupled device (CCD) camera, which together provide surface elemental mapping of solid samples. The tilting-filter spectrometer is instrumentally simpler, produces less image distortion, and achieves higher optical throughput than a monochromator-based instrument, but has a much more limited tunable spectral range and poorer spectral resolution. As a result, the tilting-filter spectrometer is limited to single-element or two-element determinations, and only when the target spectral lines fall within an appropriate spectral range and can be spectrally discerned. Spectral interferences that result from heterogeneous impurities can be flagged and overcome by observing the spatially resolved signal response across the available tunable spectral range. The instrument has been characterized and evaluated for the spatially resolved analysis of glow-discharge emission from selected but representative samples.
Zhang, Hong-guang; Lu, Jian-gang
2016-02-01
Abstract To overcome the problems of significant difference among samples and nonlinearity between the property and spectra of samples in spectral quantitative analysis, a local regression algorithm is proposed in this paper. In this algorithm, net signal analysis method(NAS) was firstly used to obtain the net analyte signal of the calibration samples and unknown samples, then the Euclidean distance between net analyte signal of the sample and net analyte signal of calibration samples was calculated and utilized as similarity index. According to the defined similarity index, the local calibration sets were individually selected for each unknown sample. Finally, a local PLS regression model was built on each local calibration sets for each unknown sample. The proposed method was applied to a set of near infrared spectra of meat samples. The results demonstrate that the prediction precision and model complexity of the proposed method are superior to global PLS regression method and conventional local regression algorithm based on spectral Euclidean distance.
Steimer, Andreas; Schindler, Kaspar
2015-01-01
Oscillations between high and low values of the membrane potential (UP and DOWN states respectively) are an ubiquitous feature of cortical neurons during slow wave sleep and anesthesia. Nevertheless, a surprisingly small number of quantitative studies have been conducted only that deal with this phenomenon’s implications for computation. Here we present a novel theory that explains on a detailed mathematical level the computational benefits of UP states. The theory is based on random sampling by means of interspike intervals (ISIs) of the exponential integrate and fire (EIF) model neuron, such that each spike is considered a sample, whose analog value corresponds to the spike’s preceding ISI. As we show, the EIF’s exponential sodium current, that kicks in when balancing a noisy membrane potential around values close to the firing threshold, leads to a particularly simple, approximative relationship between the neuron’s ISI distribution and input current. Approximation quality depends on the frequency spectrum of the current and is improved upon increasing the voltage baseline towards threshold. Thus, the conceptually simpler leaky integrate and fire neuron that is missing such an additional current boost performs consistently worse than the EIF and does not improve when voltage baseline is increased. For the EIF in contrast, the presented mechanism is particularly effective in the high-conductance regime, which is a hallmark feature of UP-states. Our theoretical results are confirmed by accompanying simulations, which were conducted for input currents of varying spectral composition. Moreover, we provide analytical estimations of the range of ISI distributions the EIF neuron can sample from at a given approximation level. Such samples may be considered by any algorithmic procedure that is based on random sampling, such as Markov Chain Monte Carlo or message-passing methods. Finally, we explain how spike-based random sampling relates to existing computational theories about UP states during slow wave sleep and present possible extensions of the model in the context of spike-frequency adaptation. PMID:26203657
Volcanic tremor and local earthquakes at Copahue volcanic complex, Southern Andes, Argentina
NASA Astrophysics Data System (ADS)
Ibáñez, J. M.; Del Pezzo, E.; Bengoa, C.; Caselli, A.; Badi, G.; Almendros, J.
2008-07-01
In the present paper we describe the results of a seismic field survey carried out at Copahue Volcano, Southern Andes, Argentina, using a small-aperture, dense seismic antenna. Copahue Volcano is an active volcano that exhibited a few phreatic eruptions in the last 20 years. The aim of this experiment was to record and classify the background seismic activity of this volcanic area, and locate the sources of local earthquakes and volcanic tremor. Data consist of several volcano-tectonic (VT) earthquakes, and many samples of back-ground seismic noise. We use both ordinary spectral, and multi-spectral techniques to measure the spectral content, and an array technique [Zero Lag Cross Correlation technique] to measure the back-azimuth and apparent slowness of the signals propagating across the array. We locate VT earthquakes using a procedure based on the estimate of slowness vector components and S-P time. VT events are located mainly along the border of the Caviahue caldera lake, positioned at the South-East of Copahue volcano, in a depth interval of 1-3 km below the surface. The background noise shows the presence of many transients with high correlation among the array stations in the frequency band centered at 2.5 Hz. These transients are superimposed to an uncorrelated background seismic signal. Array solutions for these transients show a predominant slowness vector pointing to the exploited geothermal field of "Las Maquinitas" and "Copahue Village", located about 6 km north of the array site. We interpret this coherent signal as a tremor generated by the activity of the geothermal field.
NASA Astrophysics Data System (ADS)
Haugen, Paul
Mid-infrared (MIR) spectroscopy has been a tool used to identify specific features of normal and malignant tissue samples by utilizing MIR characteristics, specifically in the "fingerprint" region. The fingerprint region is a biologically significant spectral region typically identified between 1500 and 500 cm-1. MIR spectroscopy can be used to study molecular changes and variations occurring in samples, which can then be used to fingerprint specific spectral characteristics and biomarkers in order to categorize the specimens. The most common instruments currently used in this analysis are Fourier transform infrared (FTIR) spectrometers, although properties inherent in these instruments, such as slow data collection time and an inability to specify sample location for the spectral data collection, have placed a ceiling on the clinical practicality of their use for specimen classification and identification. In this thesis, we use a prototype of an infrared hyperspectral imaging microscopy platform based around tunable quantum cascade laser (QCL) technology that has a spectral coverage from 1800-900 cm-1. The quantum cascade lasers are coupled with a series of MIR refractive objectives and an uncooled microbolometer camera. The speed of spectral imaging improves to 30 frames per second, and the high magnification objective has a 1.34 microm pixel resolution with a 0.70 numerical aperture and 4.3 microm spatial resolution. We are able to specify data collection at specific discrete wavelengths as opposed to the full spectrum, which improves the data collection time and de-clutters the data for analysis expediency. Finally, we perform spectral imaging real-time, which aides in selecting precise regions of interest on the target sample. This thesis demonstrates the advantages of exploiting the capabilities of the QCL microscope to advance MIR spectroscopy in the identification of distinguishing traits of normal and malignant breast and cervical tissue samples.
A modified Wald interval for the area under the ROC curve (AUC) in diagnostic case-control studies
2014-01-01
Background The area under the receiver operating characteristic (ROC) curve, referred to as the AUC, is an appropriate measure for describing the overall accuracy of a diagnostic test or a biomarker in early phase trials without having to choose a threshold. There are many approaches for estimating the confidence interval for the AUC. However, all are relatively complicated to implement. Furthermore, many approaches perform poorly for large AUC values or small sample sizes. Methods The AUC is actually a probability. So we propose a modified Wald interval for a single proportion, which can be calculated on a pocket calculator. We performed a simulation study to compare this modified Wald interval (without and with continuity correction) with other intervals regarding coverage probability and statistical power. Results The main result is that the proposed modified Wald intervals maintain and exploit the type I error much better than the intervals of Agresti-Coull, Wilson, and Clopper-Pearson. The interval suggested by Bamber, the Mann-Whitney interval without transformation and also the interval of the binormal AUC are very liberal. For small sample sizes the Wald interval with continuity has a comparable coverage probability as the LT interval and higher power. For large sample sizes the results of the LT interval and of the Wald interval without continuity correction are comparable. Conclusions If individual patient data is not available, but only the estimated AUC and the total sample size, the modified Wald intervals can be recommended as confidence intervals for the AUC. For small sample sizes the continuity correction should be used. PMID:24552686
A modified Wald interval for the area under the ROC curve (AUC) in diagnostic case-control studies.
Kottas, Martina; Kuss, Oliver; Zapf, Antonia
2014-02-19
The area under the receiver operating characteristic (ROC) curve, referred to as the AUC, is an appropriate measure for describing the overall accuracy of a diagnostic test or a biomarker in early phase trials without having to choose a threshold. There are many approaches for estimating the confidence interval for the AUC. However, all are relatively complicated to implement. Furthermore, many approaches perform poorly for large AUC values or small sample sizes. The AUC is actually a probability. So we propose a modified Wald interval for a single proportion, which can be calculated on a pocket calculator. We performed a simulation study to compare this modified Wald interval (without and with continuity correction) with other intervals regarding coverage probability and statistical power. The main result is that the proposed modified Wald intervals maintain and exploit the type I error much better than the intervals of Agresti-Coull, Wilson, and Clopper-Pearson. The interval suggested by Bamber, the Mann-Whitney interval without transformation and also the interval of the binormal AUC are very liberal. For small sample sizes the Wald interval with continuity has a comparable coverage probability as the LT interval and higher power. For large sample sizes the results of the LT interval and of the Wald interval without continuity correction are comparable. If individual patient data is not available, but only the estimated AUC and the total sample size, the modified Wald intervals can be recommended as confidence intervals for the AUC. For small sample sizes the continuity correction should be used.
Diagnostic capability of spectral-domain optical coherence tomography for glaucoma.
Wu, Huijuan; de Boer, Johannes F; Chen, Teresa C
2012-05-01
To determine the diagnostic capability of spectral-domain optical coherence tomography in glaucoma patients with visual field defects. Prospective, cross-sectional study. Participants were recruited from a university hospital clinic. One eye of 85 normal subjects and 61 glaucoma patients with average visual field mean deviation of -9.61 ± 8.76 dB was selected randomly for the study. A subgroup of the glaucoma patients with early visual field defects was calculated separately. Spectralis optical coherence tomography (Heidelberg Engineering, Inc) circular scans were performed to obtain peripapillary retinal nerve fiber layer (RNFL) thicknesses. The RNFL diagnostic parameters based on the normative database were used alone or in combination for identifying glaucomatous RNFL thinning. To evaluate diagnostic performance, calculations included areas under the receiver operating characteristic curve, sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio. Overall RNFL thickness had the highest area under the receiver operating characteristic curve values: 0.952 for all patients and 0.895 for the early glaucoma subgroup. For all patients, the highest sensitivity (98.4%; 95% confidence interval, 96.3% to 100%) was achieved by using 2 criteria: ≥ 1 RNFL sectors being abnormal at the < 5% level and overall classification of borderline or outside normal limits, with specificities of 88.9% (95% confidence interval, 84.0% to 94.0%) and 87.1% (95% confidence interval, 81.6% to 92.5%), respectively, for these 2 criteria. Statistical parameters for evaluating the diagnostic performance of the Spectralis spectral-domain optical coherence tomography were good for early perimetric glaucoma and were excellent for moderately advanced perimetric glaucoma. Copyright © 2012 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Pettegrew, Richard Dale
Numerical models of solid fuel combustion rely on accurate radiative property values to properly account for radiative heat transfer to and from the surface. The spectral properties can change significantly over the temperature range from ambient to burnout temperature. The variations of these properties are due to mass loss (as the sample pyrolyzes), chemical changes, and surface finish changes. In addition, band-integrated properties can vary due to the shift in the peak of the Planck curve as the temperature increases, which results in differing weightings of the spectral values. These effects were quantified for a thin cellulosic fuel commonly used in microgravity combustion studies (KimWipesRTM). Pyrolytic effects were simulated by heat-treating the samples in a constant temperature oven for varying times. Spectral data was acquired using a Fourier Transform Infrared (FTIR) spectrometer, along with an integrating sphere. Data was acquired at different incidence angles by mounting the samples at different angles inside the sphere. Comparisons of samples of similar area density created using different heat-treatment regimens showed that thermal history of the samples was irrelevant in virtually all spectral regions, with overall results correlating well with changes in area density. Spectral, angular, and thermal dependencies were determined for a representative data set, showing that the spectral absorptance decreases as the temperature increases, and decreases as the incidence angle varies from normal. Changes in absorptance are primarily offset by corresponding changes in transmittances, with reflectance values shown to be low over the tested spectral region of 2.50 mum to 24.93 mum. Band-integrated values were calculated as a function of temperature for the entire tested spectral region, as well as limited bands relevant for thermal imaging applications. This data was used to demonstrate the significant error that is likely if incorrect emittance values are used in heat transfer calculations. The pyrolyzed samples were also used to determine the activation energy and pre-exponential factor needed in the zeroth-order Arrhenius reaction, sometimes used to model the mass loss from the surface in numerical models. The values determined were used to calculate an estimated peak surface temperature, which agrees well with experimentally determined values.
Lan, Gongpu; Li, Guoqiang
2017-03-07
Nonlinear sampling of the interferograms in wavenumber (k) space degrades the depth-dependent signal sensitivity in conventional spectral domain optical coherence tomography (SD-OCT). Here we report a linear-in-wavenumber (k-space) spectrometer for an ultra-broad bandwidth (760 nm-920 nm) SD-OCT, whereby a combination of a grating and a prism serves as the dispersion group. Quantitative ray tracing is applied to optimize the linearity and minimize the optical path differences for the dispersed wavenumbers. Zemax simulation is used to fit the point spread functions to the rectangular shape of the pixels of the line-scan camera and to improve the pixel sampling rates. An experimental SD-OCT is built to test and compare the performance of the k-space spectrometer with that of a conventional one. Design results demonstrate that this k-space spectrometer can reduce the nonlinearity error in k-space from 14.86% to 0.47% (by approximately 30 times) compared to the conventional spectrometer. The 95% confidence interval for RMS diameters is 5.48 ± 1.76 μm-significantly smaller than both the pixel size (14 μm × 28 μm) and the Airy disc (25.82 μm in diameter, calculated at the wavenumber of 7.548 μm -1 ). Test results demonstrate that the fall-off curve from the k-space spectrometer exhibits much less decay (maximum as -5.20 dB) than the conventional spectrometer (maximum as -16.84 dB) over the whole imaging depth (2.2 mm).
NASA Astrophysics Data System (ADS)
Lan, Gongpu; Li, Guoqiang
2017-03-01
Nonlinear sampling of the interferograms in wavenumber (k) space degrades the depth-dependent signal sensitivity in conventional spectral domain optical coherence tomography (SD-OCT). Here we report a linear-in-wavenumber (k-space) spectrometer for an ultra-broad bandwidth (760 nm-920 nm) SD-OCT, whereby a combination of a grating and a prism serves as the dispersion group. Quantitative ray tracing is applied to optimize the linearity and minimize the optical path differences for the dispersed wavenumbers. Zemax simulation is used to fit the point spread functions to the rectangular shape of the pixels of the line-scan camera and to improve the pixel sampling rates. An experimental SD-OCT is built to test and compare the performance of the k-space spectrometer with that of a conventional one. Design results demonstrate that this k-space spectrometer can reduce the nonlinearity error in k-space from 14.86% to 0.47% (by approximately 30 times) compared to the conventional spectrometer. The 95% confidence interval for RMS diameters is 5.48 ± 1.76 μm—significantly smaller than both the pixel size (14 μm × 28 μm) and the Airy disc (25.82 μm in diameter, calculated at the wavenumber of 7.548 μm-1). Test results demonstrate that the fall-off curve from the k-space spectrometer exhibits much less decay (maximum as -5.20 dB) than the conventional spectrometer (maximum as -16.84 dB) over the whole imaging depth (2.2 mm).
Technical brief: Pump-probe paradigm in an integrating cavity to study photodecomposition processes
Betts-Obregon, Brandi; Tsin, Andrew T.; DeSa, Richard J.
2016-01-01
Purpose Assaying photodecomposition is challenging because light must be used to initiate the photodamage and light must be used to monitor the photodecomposition. The experimental requirements are as follows: 1) During exposure of the actinic beam, continuously monitor the spectral characteristics of the sample, 2) uniformly expose the reactants to the actinic source, 3) obtain informative spectra in the presence of light scatter, and 4) achieve sufficient sensitivity for dilute reactants. Traditional spectrophotometers cannot address these issues due to sample turbidity, the inability to uniformly expose the cuvette contents to the incident beam, the inability to simultaneously perform spectral scans, and inherent low sensitivity. Here, we describe a system that meets these challenges in a practical way. Methods Light access to a 8.6 ml quartz integrating sphere containing 10 µM all-trans retinol in PBS was provided by three ports at right angles allowing for the following: 1) actinic light delivery from light-emitting diodes (LEDs) firing at 100 pulses/sec, 2) entry of a separate scanning beam at 100 scans/sec (10,000 µsec scan time) via an OLIS RSM 1000 ultraviolet/visual (UV/Vis) rapid-scanning spectrophotometer (RSM), and 3) light exit to the detector photomultiplier. The RSM spectral intermediate slit was partially covered to allow for a “dark” period of 2,000 µsec when no scanning light was admitted to the cuvette. During that interval, the LED was flashed, and the photomultiplier was temporarily blocked by a perforated spinning shutter disk. The absorbance per centimeter, which is increased due to the internal reflectance of the integrating sphere compared to a standard 1 cm rectangular cuvette, was calculated according to Fry et al. (2010) Applied Optics 49:575. Retinoid photodecomposition was confirmed with high-performance liquid chromatography (HPLC). Results Using the RSM to trigger the LED flash and photomultiplier shutter closure during the “dark” period allowed actinic flashes to be placed between scans. Exposure of the all-trans retinol to 366 nm flashes resulted in marked reduction in absorbance and a blue shift of the λmax. A white LED, despite its higher photon output, did not support all-trans retinol photolysis. Singular value decomposition (SVD) analysis revealed three spectral intermediates with mechanism, I -> II -> III. HPLC analysis of the reactants at the beginning and the conclusion of the light exposure confirmed the retinol photodecomposition. Conclusions The highly reflecting cavity acts as a multipass cuvette that markedly increased the light path length and, thus, sensitivity. Triggering the LED during a dark period within the scan time allowed the actinic flashes to be interleafed between scans in a pump-probe paradigm. Furthermore, the entire sample was exposed to scan beam and actinic flashes, which is not possible in traditional spectrophotometers. Finally, the integrating cavity cuvette allowed use of turbid samples. SVD was useful for resolving spectral intermediates. Although the identity of the intermediates was not determined here, the ability to define molecular intermediates during photodecomposition reactions will allow future studies to isolate and identify the degradation products and determine the mechanism of light-induced retinoid degradation and that of retinoid-binding protein-mediated photoprotection. PMID:27559291
2013-01-01
Peak alignment is a critical procedure in mass spectrometry-based biomarker discovery in metabolomics. One of peak alignment approaches to comprehensive two-dimensional gas chromatography mass spectrometry (GC×GC-MS) data is peak matching-based alignment. A key to the peak matching-based alignment is the calculation of mass spectral similarity scores. Various mass spectral similarity measures have been developed mainly for compound identification, but the effect of these spectral similarity measures on the performance of peak matching-based alignment still remains unknown. Therefore, we selected five mass spectral similarity measures, cosine correlation, Pearson's correlation, Spearman's correlation, partial correlation, and part correlation, and examined their effects on peak alignment using two sets of experimental GC×GC-MS data. The results show that the spectral similarity measure does not affect the alignment accuracy significantly in analysis of data from less complex samples, while the partial correlation performs much better than other spectral similarity measures when analyzing experimental data acquired from complex biological samples. PMID:24151524
Crowley, J.K.; Williams, D.E.; Hammarstrom1, J.M.; Piatak, N.; Mars, J.C.; Chou, I-Ming
2006-01-01
Fifteen Fe-oxide, Fe-hydroxide, and Fe-sulphate-hydrate mineral species commonly associated with sulphide bearing mine wastes were characterized by using X-ray powder diffraction and scanning electron microscope methods. Diffuse reflectance spectra of the samples show diagnostic absorption features related to electronic processes involving ferric and/or ferrous iron, and to vibrational processes involving water and hydroxyl ions. Such spectral features enable field and remote sensing based studies of the mineral distributions. Because secondary minerals are sensitive indicators of pH, Eh, relative humidity, and other environmental conditions, spectral mapping of these minerals promises to have important applications to mine waste remediation studies. This report releases digital (ascii) spectra (spectral_data_files.zip) of the fifteen mineral samples to facilitate usage of the data with spectral libraries and spectral analysis software. The spectral data are provided in a two-column format listing wavelength (in micrometers) and reflectance, respectively.
Compressive Spectral Method for the Simulation of the Nonlinear Gravity Waves
Bayındır, Cihan
2016-01-01
In this paper an approach for decreasing the computational effort required for the spectral simulations of the fully nonlinear ocean waves is introduced. The proposed approach utilizes the compressive sampling algorithm and depends on the idea of using a smaller number of spectral components compared to the classical spectral method. After performing the time integration with a smaller number of spectral components and using the compressive sampling technique, it is shown that the ocean wave field can be reconstructed with a significantly better efficiency compared to the classical spectral method. For the sparse ocean wave model in the frequency domain the fully nonlinear ocean waves with Jonswap spectrum is considered. By implementation of a high-order spectral method it is shown that the proposed methodology can simulate the linear and the fully nonlinear ocean waves with negligible difference in the accuracy and with a great efficiency by reducing the computation time significantly especially for large time evolutions. PMID:26911357
In-orbit verification of MHS spectral channels co-registration using the moon
NASA Astrophysics Data System (ADS)
Bonsignori, Roberto
2017-09-01
In-orbit verification of the co-registration of channels in a scanning microwave or infrared radiometer can in principle be done during normal in-orbit operation, by using the regular events of lunar intrusion in the instrument cold space calibration view. A technique of data analysis based on best fit of data across lunar intrusions has been used to check the mutual alignment of the spectral channels of the MHS instrument. MHS (Microwave Humidity Sounder) is a cross-track scanning radiometer in the millimetre-wave range flying on EUMETSAT and NOAA polar satellites, used operationally for the retrieval of atmospheric parameters in numerical weather prediction and nowcasting. This technique does not require any special operation or manoeuvre and only relies on analysis of data from the nominal scanning operation. The co-alignment of sounding channels and window channels can be evaluated by this technique, which would not be possible by using earth landmarks, due to the absorption effect of the atmosphere. The analysis reported in this paper shows an achievable accuracy below 0.5 mrad against a beam width at 3dB and spatial sampling interval of about 20 mrad. In-orbit results for the MHS instrument on Metop-B are also compared with the pre-launch instrument characterisation, showing a good correlation.
Zaltariov, Mirela-Fernanda; Bele, Adrian; Vasiliu, Lavinia; Gradinaru, Luiza; Vornicu, Nicoleta; Racles, Carmen; Cazacu, Maria
2018-01-05
A series of elastomers, either natural or synthetic (some of them commercial, while others prepared in the laboratory), suitable for use as active elements in devices for wave energy harvesting, were evaluated concerning their behavior and effects on the marine environment. In this aim, the elastomer films, initially evaluated regarding their aspect, structure, surface wettability, and tolerance of microorganisms growth, were immersed in synthetic seawater (SSW) within six months for assessing compounds released. There were analyzed the changes occurred both in the elastomers and salt water in which they were immersed. For this, water samples taken at set time intervals were analyzed by using a sequence of sensitive spectral techniques: UV-vis, IR, and in relevant cases 1 H NMR and electrospray ionization mass spectrometry (ESI-MS), able to detect and identify organic compounds, while after six months, they were also investigated from the point of view of aspect, presence of metal traces, pH, and biological activity. The changes in aspect, structure and morphology of the dielectric films at the end of the dipping period were also evaluated by visual inspection, IR spectroscopy by using spectral subtraction method, and SEM-EDX technique. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Boesch, Hartmut; Toon, G.; Sen, B; Li, Q. B.; Salawitch, R.; Miller, C.; Crisp, D.; Washenfelder, R.; Wennberg, P.; Natraj, V.;
2006-01-01
Global, space-based observations of atmospheric CO2 with precision, resolution, and coverage needed to monitor sources and sinks: a) Spectra of reflected/scattered sunlight in NIR CO2 and O2 bands used to estimate X(sub CO2) with large sensitivity to surface; b) A-train orbit (1:15 PM polar sun sync); c) 16 day repeat cycle samples seasonal cycle on semi-monthly intervals; and d) NASA ESSP (Earth Space System Pathfinder) scheduled for Sept 2008 launch; 2 yrs lifetime. Initial comparison of SCIAMACHY and FTS retrievals for Park Falls: a) Positive bias in X(sub CO2) of approx. 10 ppm; and b) Negative bias in surface pressure After correction of spectral artifacts in O2A band: a) Largely improved agreement between SCIAMACHY and FTS X(sub CO2) (without clear bias) and in surface pressure; and b) Standard deviation of SCIAMACHY X(sub CO2 approx. 6 ppm. Good qualitative agreement with GEOS-CHEM, with GEOS-CHEM underestimating seasonal cycle. OCO is a dedicated CO2 instrument and will achieve much higher accuracy and precision: a) much higher spectral resolution (by factor of 20); and b) smaller ground pixels (by factor of 600).
EnviroAtlas Cyanobacteria Assessment Network (CyAN) ...
Economic, health, and environmental impacts of cyanobacteria and associated harmful algal blooms are increasingly recognized by policymakers, managers, and scientific researchers. However, spatially-distributed, long-term data on cyanobacteria blooms are largely unavailable. The multiagency Cyanobacteria Assessment Network (CyAN) project helps address this data need by providing remote-sensing derived information on the concentration of cyanobacteria in fresh water bodies of the Continental United States. CyAN provides data for >1 ,800 lakes using 300x300 meter MERIS and Sentinel-3 satellite image data processed using a second-derivative spectral-shape cyanobacteria algorithm. CyAN includes weekly information for over 200,000 km2 of surface water for 2008-2012, a breadth of spatiotemporal information unprecedented in cyanobacteria research. Online distribution and effective communication of CyAN issues are high priorities for the project and sharing these data offer exceptional opportunities for research, management, and public awareness of cyanobacteria. Challenges that these data pose for webbased data visualization include uneven sampling intervals due to cloud cover, inconsistent spatial data coverage associated with spectral interference and lake "edge effects," and widely varying lake sizes prohibiting presentation of data at the waterbody scale. We present an approach that overcomes these challenges by incorporating a variety of data visualization techniq
SWIFT Discovery of Gamma-ray Bursts without Jet Break Feature in their X-ray Afterglows
NASA Technical Reports Server (NTRS)
Sato, G.; Yamazaki, R.; Sakamoto, T.; Takahashi, T; Nakazawa, K.; Nakamura, T.; Toma, K.; Hullinger, D.; Tashiro, M.; Parsons, A. M.;
2007-01-01
We analyze Swift gamma-ray bursts (GRBs) and X-ray afterglows for three GRBs with spectroscopic redshift determinations - GRB 050401, XRF 050416a, and GRB 050525a. We find that the relation between spectral peak energy and isotropic energy of prompt emissions (the Amati relation) is consistent with that for the bursts observed in pre-Swift era. However, we find that the X-ray afterglow lightcurves, which extend up to 10 - 70 days, show no sign of the jet break that is expected in the standard framework of collimated outflows. We do so by showing that none of the X-ray afterglow lightcurves in our sample satisfies the relation between the spectral and temporal indices that is predicted for the phase after jet break. The jet break time can be predicted by inverting the tight empirical relation between the peak energy of the spectrum and the collimation-corrected energy of the prompt emission (the Ghirlanda relation). We find that there are no temporal breaks within the predicted time intervals in X-ray band. This requires either that the Ghirlanda relation has a larger scatter than previously thought, that the temporal break in X-rays is masked by some additional source of X-ray emission, or that it does not happen because of some unknown reason.
Pullin, A N; Pairis-Garcia, M D; Campbell, B J; Campler, M R; Proudfoot, K L
2017-11-01
When considering methodologies for collecting behavioral data, continuous sampling provides the most complete and accurate data set whereas instantaneous sampling can provide similar results and also increase the efficiency of data collection. However, instantaneous time intervals require validation to ensure accurate estimation of the data. Therefore, the objective of this study was to validate scan sampling intervals for lambs housed in a feedlot environment. Feeding, lying, standing, drinking, locomotion, and oral manipulation were measured on 18 crossbred lambs housed in an indoor feedlot facility for 14 h (0600-2000 h). Data from continuous sampling were compared with data from instantaneous scan sampling intervals of 5, 10, 15, and 20 min using a linear regression analysis. Three criteria determined if a time interval accurately estimated behaviors: 1) ≥ 0.90, 2) slope not statistically different from 1 ( > 0.05), and 3) intercept not statistically different from 0 ( > 0.05). Estimations for lying behavior were accurate up to 20-min intervals, whereas feeding and standing behaviors were accurate only at 5-min intervals (i.e., met all 3 regression criteria). Drinking, locomotion, and oral manipulation demonstrated poor associations () for all tested intervals. The results from this study suggest that a 5-min instantaneous sampling interval will accurately estimate lying, feeding, and standing behaviors for lambs housed in a feedlot, whereas continuous sampling is recommended for the remaining behaviors. This methodology will contribute toward the efficiency, accuracy, and transparency of future behavioral data collection in lamb behavior research.
Spectrally-encoded color imaging
Kang, DongKyun; Yelin, Dvir; Bouma, Brett E.; Tearney, Guillermo J.
2010-01-01
Spectrally-encoded endoscopy (SEE) is a technique for ultraminiature endoscopy that encodes each spatial location on the sample with a different wavelength. One limitation of previous incarnations of SEE is that it inherently creates monochromatic images, since the spectral bandwidth is expended in the spatial encoding process. Here we present a spectrally-encoded imaging system that has color imaging capability. The new imaging system utilizes three distinct red, green, and blue spectral bands that are configured to illuminate the grating at different incident angles. By careful selection of the incident angles, the three spectral bands can be made to overlap on the sample. To demonstrate the method, a bench-top system was built, comprising a 2400-lpmm grating illuminated by three 525-μm-diameter beams with three different spectral bands. Each spectral band had a bandwidth of 75 nm, producing 189 resolvable points. A resolution target, color phantoms, and excised swine small intestine were imaged to validate the system's performance. The color SEE system showed qualitatively and quantitatively similar color imaging performance to that of a conventional digital camera. PMID:19688002
Hyperspectral analysis of clay minerals
NASA Astrophysics Data System (ADS)
Janaki Rama Suresh, G.; Sreenivas, K.; Sivasamy, R.
2014-11-01
A study was carried out by collecting soil samples from parts of Gwalior and Shivpuri district, Madhya Pradesh in order to assess the dominant clay mineral of these soils using hyperspectral data, as 0.4 to 2.5 μm spectral range provides abundant and unique information about many important earth-surface minerals. Understanding the spectral response along with the soil chemical properties can provide important clues for retrieval of mineralogical soil properties. The soil samples were collected based on stratified random sampling approach and dominant clay minerals were identified through XRD analysis. The absorption feature parameters like depth, width, area and asymmetry of the absorption peaks were derived from spectral profile of soil samples through DISPEC tool. The derived absorption feature parameters were used as inputs for modelling the dominant soil clay mineral present in the unknown samples using Random forest approach which resulted in kappa accuracy of 0.795. Besides, an attempt was made to classify the Hyperion data using Spectral Angle Mapper (SAM) algorithm with an overall accuracy of 68.43 %. Results showed that kaolinite was the dominant mineral present in the soils followed by montmorillonite in the study area.
Computerized EEG analysis for studying the effect of drugs on the central nervous system.
Rosadini, G; Cavazza, B; Rodriguez, G; Sannita, W G; Siccardi, A
1977-11-01
Samples of our experience in quantitative pharmaco-EEG are reviewed to discuss and define its applicability and limits. Simple processing systems, such as the computation of Hjorth's descriptors, are useful for on-line monitoring of drug-induced EEG modifications which are evident also at the visual visual analysis. Power spectral analysis is suitable to identify and quantify EEG effects not evident at the visual inspection. It demonstrated how the EEG effects of compounds in a long-acting formulation vary according to the sampling time and the explored cerebral area. EEG modifications not detected by power spectral analysis can be defined by comparing statistically (F test) the spectral values of the EEG from a single lead at the different samples (longitudinal comparison), or the spectral values from different leads at any sample (intrahemispheric comparison). The presently available procedures of quantitative pharmaco-EEG are effective when applied to the study of mutltilead EEG recordings in a statistically significant sample of population. They do not seem reliable in the monitoring of directing of neuropyschiatric therapies in single patients, due to individual variability of drug effects.
The US Geological Survey, digital spectral reflectance library: version 1: 0.2 to 3.0 microns
NASA Technical Reports Server (NTRS)
Clark, Roger N.; Swayze, Gregg A.; King, Trude V. V.; Gallagher, Andrea J.; Calvin, Wendy M.
1993-01-01
We have developed a digital reflectance spectral library, with management and spectral analysis software. The library includes 500 spectra of 447 samples (some samples include a series of grain sizes) measured from approximately 0.2 to 3.0 microns. The spectral resolution (Full Width Half Maximum) of the reflectance data is less than or equal to 4 nm in the visible (0.2-0.8 microns) and less than or equal 10 nm in the NIR (0.8-2.35 microns). All spectra were corrected to absolute reflectance using an NBS Halon standard. Library management software lets users search on parameters (e.g. chemical formulae, chemical analyses, purity of samples, mineral groups, etc.) as well as spectral features. Minerals from sulfide, oxide, hydroxide, halide, carbonate, nitrate, borate, phosphate, and silicate groups are represented. X-ray and chemical analyses are tabulated for many of the entries, and all samples have been evaluated for spectral purity. The library also contains end and intermediate members for the olivine, garnet, scapolite, montmorillonite, muscovite, jarosite, and alunite solid-solution series. We have included representative spectra of H2O ice, kerogen, ammonium-bearing minerals, rare-earth oxides, desert varnish coatings, kaolinite crystallinity series, kaolinite-smectite series, zeolite series, and an extensive evaporite series. Because of the importance of vegetation to climate-change studies we have include 17 spectra of tree leaves, bushes, and grasses.
Changes in the Far UV Spectrum of Eta Carinae Near the 2003 Minimum
NASA Technical Reports Server (NTRS)
Iping, R. C.; Gull, T. R.; Sonneborn, G.; Massa, D.; Vieira, G. L.; Nielsen, K. E.
2004-01-01
High resolution 905-1180 spectra of \\eta Carinae have been obtained with the Far Ultraviolet Spectroscopic Explorer (FUSE) satellite at nine epochs between February 2000 and June 2003 . This period of time extends from the broad maximum up to the very beginning of the minimum of the 5.52-year period initially discovered by A. Damineli. The flux levels were unchanged between February 2000 through February 2003 with minor spectral differences. The X-Ray minimum started on June 29, 2003 . Three observations were accomplished on June 10, June 17 and June 27 leading up to the minimum. Substantial changes were present in the June 10 and June 17 spectra, but a very significant change occurred by June 27, 2003. Longward of 1100A, the overall flux dropped 10 to 30 %. Shortward of 1100A, there are spectral intervals with NO decrease in flux even down to the shortest wavelengths (920--950 ). This indicates that dust absorption has a negligible role in the observed spectral changes and that line absorptions play a major role. Throughout the spectrum there are intervals ranging in width of 3-10A with strong increased absorption. Significant absorptions may be associated with the red portion of the following stellar wind lines: C III 977, O VI 1031,1037, P V 1117, while other absorption features are much broader, more extended and not clearly associated with well-known spectral transitions. Given the complexity of the STIS echelle spectra taken in this period of time, many of these absorption features are likely due to multiple absorption lines
Multiplicative point process as a model of trading activity
NASA Astrophysics Data System (ADS)
Gontis, V.; Kaulakys, B.
2004-11-01
Signals consisting of a sequence of pulses show that inherent origin of the 1/ f noise is a Brownian fluctuation of the average interevent time between subsequent pulses of the pulse sequence. In this paper, we generalize the model of interevent time to reproduce a variety of self-affine time series exhibiting power spectral density S( f) scaling as a power of the frequency f. Furthermore, we analyze the relation between the power-law correlations and the origin of the power-law probability distribution of the signal intensity. We introduce a stochastic multiplicative model for the time intervals between point events and analyze the statistical properties of the signal analytically and numerically. Such model system exhibits power-law spectral density S( f)∼1/ fβ for various values of β, including β= {1}/{2}, 1 and {3}/{2}. Explicit expressions for the power spectra in the low-frequency limit and for the distribution density of the interevent time are obtained. The counting statistics of the events is analyzed analytically and numerically, as well. The specific interest of our analysis is related with the financial markets, where long-range correlations of price fluctuations largely depend on the number of transactions. We analyze the spectral density and counting statistics of the number of transactions. The model reproduces spectral properties of the real markets and explains the mechanism of power-law distribution of trading activity. The study provides evidence that the statistical properties of the financial markets are enclosed in the statistics of the time interval between trades. A multiplicative point process serves as a consistent model generating this statistics.
Ramírez-Vélez, Robinson; Tordecilla-Sanders, Alejandra; Téllez-T, Luis Andrés; Camelo-Prieto, Diana; Hernández-Quiñonez, Paula Andrea; Correa-Bautista, Jorge Enrique; Garcia-Hermoso, Antonio; Ramírez-Campillo, Rodrigo; Izquierdo, Mikel
2017-02-01
We investigated the effect of moderate versus high-intensity interval exercise training on the HRV indices in physically inactive adults. Twenty inactive adults were randomly allocated to receive either moderate intensity training (MCT group) or high-intensity interval training (HIT group). The MCT group performed aerobic training at an intensity of 55-75%, which consisted of walking on a treadmill at 60-80% of the maximum heart rate (HRmax) until the expenditure of 300 kcal. The HIT group ran on a treadmill for 4 minutes at 85-95% peak HRmax and had a recovery of 4 minutes at 65% peak HRmax until the expenditure of 300 kcal. Supine resting HRV indices (time domain: SDNN, standard deviation of normal-to-normal intervals; rMSSD, Root mean square successive difference of RR intervals and frequency domain: HFLn, high-frequency spectral power; LF, low-frequency spectral power and HF/LF ratio) were measured at baseline and 12 weeks thereafter. The SDNN changes were 3.4 (8.9) ms in the MCT group and 29.1 (7.6) ms in the HIT group (difference between groups 32.6 [95% CI, 24.9 to 40.4 (P = 0.01)]. The LF/HFLn ratio change 0.19 (0.03) ms in the MCT group and 0.13 (0.01) ms in the HIT group (P between groups = 0.016). No significant group differences were observed for the rMSSD, HF and LF parameters. In inactive adults, this study showed that a 12-week HIT training program could increase short-term HRV, mostly in vagally mediated indices such as SDNN and HF/LFLn ratio power.
Spectral reflectance properties of carbon-bearing materials
NASA Technical Reports Server (NTRS)
Cloutis, Edward A.; Gaffey, Michael J.; Moslow, Thomas F.
1994-01-01
The 0.3-2.6 micrometers spectral reflectance properties of carbon polymorphs (graphite, carbon black, diamond), carbides (silicon carbide, cementite), and macromolecular organic-bearing materials (coal, coal tar extract, oil sand, oil shale) are found to vary from sample to sample and among groups. The carbon polymorphs are readily distinguishable on the basis of their visible-near infrared spectral slopes and shapes. The spectra of macromolecular organic-bearing materials show increases in reflectance toward longer wavelengths, exceeding the reflectance rise of more carbon-rich materials. Reflectance spectra of carbonaceous materials are affected by the crystal structure, composition, and degree of order/disorder of the samples. The characteristic spectral properties can potentially be exploited to identify individual carbonaceous grains in meteorites (as separates or in situ) or to conduct remote sensing geothermometry and identification of carbonaceous phases on asteroids.
Woess, Claudia; Unterberger, Seraphin Hubert; Roider, Clemens; Ritsch-Marte, Monika; Pemberger, Nadin; Cemper-Kiesslich, Jan; Hatzer-Grubwieser, Petra; Parson, Walther; Pallua, Johannes Dominikus
2017-01-01
Due to the influence of many environmental processes, a precise determination of the post-mortem interval (PMI) of skeletal remains is known to be very complicated. Although methods for the investigation of the PMI exist, there still remains much room for improvement. In this study the applicability of infrared (IR) microscopic imaging techniques such as reflection-, ATR- and Raman- microscopic imaging for the estimation of the PMI of human skeletal remains was tested. PMI specific features were identified and visualized by overlaying IR imaging data with morphological tissue structures obtained using light microscopy to differentiate between forensic and archaeological bone samples. ATR and reflection spectra revealed that a more prominent peak at 1042 cm-1 (an indicator for bone mineralization) was observable in archeological bone material when compared with forensic samples. Moreover, in the case of the archaeological bone material, a reduction in the levels of phospholipids, proteins, nucleic acid sugars, complex carbohydrates as well as amorphous or fully hydrated sugars was detectable at (reciprocal wavelengths/energies) between 3000 cm-1 to 2800 cm-1. Raman spectra illustrated a similar picture with less ν2PO43-at 450 cm-1 and ν4PO43- from 590 cm-1 to 584 cm-1, amide III at 1272 cm-1 and protein CH2 deformation at 1446 cm-1 in archeological bone material/samples/sources. A semi-quantitative determination of various distributions of biomolecules by chemi-maps of reflection- and ATR- methods revealed that there were less carbohydrates and complex carbohydrates as well as amorphous or fully hydrated sugars in archaeological samples compared with forensic bone samples. Raman- microscopic imaging data showed a reduction in B-type carbonate and protein α-helices after a PMI of 3 years. The calculated mineral content ratio and the organic to mineral ratio displayed that the mineral content ratio increases, while the organic to mineral ratio decreases with time. Cluster-analyses of data from Raman microscopic imaging reconstructed histo-anatomical features in comparison to the light microscopic image and finally, by application of principal component analyses (PCA), it was possible to see a clear distinction between forensic and archaeological bone samples. Hence, the spectral characterization of inorganic and organic compounds by the afore mentioned techniques, followed by analyses such as multivariate imaging analysis (MIAs) and principal component analyses (PCA), appear to be suitable for the post mortem interval (PMI) estimation of human skeletal remains.
Roider, Clemens; Ritsch-Marte, Monika; Pemberger, Nadin; Cemper-Kiesslich, Jan; Hatzer-Grubwieser, Petra; Parson, Walther; Pallua, Johannes Dominikus
2017-01-01
Due to the influence of many environmental processes, a precise determination of the post-mortem interval (PMI) of skeletal remains is known to be very complicated. Although methods for the investigation of the PMI exist, there still remains much room for improvement. In this study the applicability of infrared (IR) microscopic imaging techniques such as reflection-, ATR- and Raman- microscopic imaging for the estimation of the PMI of human skeletal remains was tested. PMI specific features were identified and visualized by overlaying IR imaging data with morphological tissue structures obtained using light microscopy to differentiate between forensic and archaeological bone samples. ATR and reflection spectra revealed that a more prominent peak at 1042 cm-1 (an indicator for bone mineralization) was observable in archeological bone material when compared with forensic samples. Moreover, in the case of the archaeological bone material, a reduction in the levels of phospholipids, proteins, nucleic acid sugars, complex carbohydrates as well as amorphous or fully hydrated sugars was detectable at (reciprocal wavelengths/energies) between 3000 cm-1 to 2800 cm-1. Raman spectra illustrated a similar picture with less ν2PO43−at 450 cm-1 and ν4PO43− from 590 cm-1 to 584 cm-1, amide III at 1272 cm-1 and protein CH2 deformation at 1446 cm-1 in archeological bone material/samples/sources. A semi-quantitative determination of various distributions of biomolecules by chemi-maps of reflection- and ATR- methods revealed that there were less carbohydrates and complex carbohydrates as well as amorphous or fully hydrated sugars in archaeological samples compared with forensic bone samples. Raman- microscopic imaging data showed a reduction in B-type carbonate and protein α-helices after a PMI of 3 years. The calculated mineral content ratio and the organic to mineral ratio displayed that the mineral content ratio increases, while the organic to mineral ratio decreases with time. Cluster-analyses of data from Raman microscopic imaging reconstructed histo-anatomical features in comparison to the light microscopic image and finally, by application of principal component analyses (PCA), it was possible to see a clear distinction between forensic and archaeological bone samples. Hence, the spectral characterization of inorganic and organic compounds by the afore mentioned techniques, followed by analyses such as multivariate imaging analysis (MIAs) and principal component analyses (PCA), appear to be suitable for the post mortem interval (PMI) estimation of human skeletal remains. PMID:28334006
Fractional spectral and pseudo-spectral methods in unbounded domains: Theory and applications
NASA Astrophysics Data System (ADS)
Khosravian-Arab, Hassan; Dehghan, Mehdi; Eslahchi, M. R.
2017-06-01
This paper is intended to provide exponentially accurate Galerkin, Petrov-Galerkin and pseudo-spectral methods for fractional differential equations on a semi-infinite interval. We start our discussion by introducing two new non-classical Lagrange basis functions: NLBFs-1 and NLBFs-2 which are based on the two new families of the associated Laguerre polynomials: GALFs-1 and GALFs-2 obtained recently by the authors in [28]. With respect to the NLBFs-1 and NLBFs-2, two new non-classical interpolants based on the associated- Laguerre-Gauss and Laguerre-Gauss-Radau points are introduced and then fractional (pseudo-spectral) differentiation (and integration) matrices are derived. Convergence and stability of the new interpolants are proved in detail. Several numerical examples are considered to demonstrate the validity and applicability of the basis functions to approximate fractional derivatives (and integrals) of some functions. Moreover, the pseudo-spectral, Galerkin and Petrov-Galerkin methods are successfully applied to solve some physical ordinary differential equations of either fractional orders or integer ones. Some useful comments from the numerical point of view on Galerkin and Petrov-Galerkin methods are listed at the end.
Temporal spectral response of a corn canopy
NASA Technical Reports Server (NTRS)
Markham, B. L.; Kimes, D. S.; Tucker, C. J.; Mcmurtrey, J. E., III
1981-01-01
Techniques developed for the prediction of winter wheat yields from remotely sensed data indicating crop status over the growing season are tested for their applicability to corn. Ground-based spectral measurements in the Landsat Thematic Mapper bands 3 (0.62-0.69 microns), 4 (0.76-0.90 microns) and 5 (1.55-1.75 microns) were performed at one-week intervals throughout the growing season for 24 plots of corn, and analyzed to derive spectral ratios and normalized spectral differences of the IR and shortwave IR bands with the red. The ratios of the near IR and shortwave IR bands are found to provide the highest and most consistent correlations with corn yield and dry matter accumulation, however the value of band 5 could not be tested due to the absence of water stress conditions. Integration of spectral ratios over several dates improved the correlations over those of any single date by achieving a seasonal, rather than instantaneous, estimate of crop status. Results point to the desirability of further tests under other growth conditions to determine whether satellite-derived data will be useful in providing corn yield information.
Atmospheric Emitted Radiance Interferometer (AERI) Handbook
Gero, Jonathan; Hackel, Denny; Garcia, Raymond
2005-01-01
The atmospheric emitted radiance interferometer (AERI) is a ground-based instrument that measures the downwelling infrared radiance from the Earth's atmosphere. The observations have broad spectral content and sufficient spectral resolution to discriminate among gaseous emitters (e.g., carbon dioxide and water vapor) and suspended matter (e.g., aerosols, water droplets, and ice crystals). These upward-looking surface observations can be used to obtain vertical profiles of tropospheric temperature and water vapor, as well as measurements of trace gases (e.g., ozone, carbon monoxide, and methane) and downwelling infrared spectral signatures of clouds and aerosols.The AERI is a passive remote sounding instrument, employing a Fourier transform spectrometer operating in the spectral range 3.3-19.2 μm (520-3020 cm-1) at an unapodized resolution of 0.5 cm-1 (max optical path difference of 1 cm). The extended-range AERI (ER-AERI) deployed in dry climates, like in Alaska, have a spectral range of 3.3-25.0 μm (400-3020 cm-1) that allow measurements in the far-infrared region. Typically, the AERI averages views of the sky over a 16-second interval and operates continuously.
Spectrally-Invariant Approximation Within Atmospheric Radiative Transfer
NASA Technical Reports Server (NTRS)
Marshak, A.; Knyazikhin, Y.; Chiu, J. C.; Wiscombe, W. J.
2011-01-01
Certain algebraic combinations of single scattering albedo and solar radiation reflected from, or transmitted through, vegetation canopies do not vary with wavelength. These "spectrally invariant relationships" are the consequence of wavelength independence of the extinction coefficient and scattering phase function in vegetation. In general, this wavelength independence does not hold in the atmosphere, but in clouddominated atmospheres the total extinction and total scattering phase function vary only weakly with wavelength. This paper identifies the atmospheric conditions under which the spectrally invariant approximation can accurately describe the extinction. and scattering properties of cloudy atmospheres. The validity of the assumptions and the accuracy of the approximation are tested with ID radiative transfer calculations using publicly available radiative transfer models: Discrete Ordinate Radiative Transfer (DISORT) and Santa Barbara DISORT Atmospheric Radiative Transfer (SBDART). It is shown for cloudy atmospheres with cloud optical depth above 3, and for spectral intervals that exclude strong water vapor absorption, that the spectrally invariant relationships found in vegetation canopy radiative transfer are valid to better than 5%. The physics behind this phenomenon, its mathematical basis, and possible applications to remote sensing and climate are discussed.
Refractive index measurements in absorbing media with white light spectral interferometry.
Arosa, Yago; Lago, Elena López; de la Fuente, Raúl
2018-03-19
White light spectral interferometry is applied to measure the refractive index in absorbing liquids in the spectral range of 400-1000 nm. We analyze the influence of absorption on the visibility of interferometric fringes and, accordingly, on the measurement of the refractive index. Further, we show that the refractive index in the absorption band can be retrieved by a two-step process. The procedure requires the use of two samples of different thickness, the thicker one to retrieve the refractive index in the transparent region and the thinnest to obtain the data in the absorption region. First, the refractive index values are retrieved with good accuracy in the transparent region of the material for 1-mm-thick samples. Second, these refractive index values serve also to precisely calculate the thickness of a thinner sample (~150 µm) since the accuracy of the methods depends strongly on the thickness of the sample. Finally, the refractive index is recovered for the entire spectral range.
Lessons Learned from Preparing OSIRIS-REx Spectral Analog Samples for Bennu
NASA Technical Reports Server (NTRS)
Schrader, D. L.; McCoy, T. J.; Cody, G. D.; King, A. J.; Schofield, P. F.; Russell, S. S.; Connolly, H. C., Jr.; Keller, L. P.; Donaldson Hanna, K.; Bowles, N.;
2017-01-01
NASA's OSIRIS-REx sample return mission launched on September 8th, 2016 to rendezvous with B-type asteroid (101955) Bennu in 2018. Type C and B asteroids have been linked to carbonaceous chondrites because of their similar visible - to - near infrared (VIS-NIR) spectral properties [e.g., 1,2]. The OSIRIS-REx Visible and Infrared Spectrometer (OVIRS) and the Thermal Emission Spectrometer (OTES) will make spectroscopic observations of Bennu during the encounter. Constraining the presence or absence of hydrous minerals (e.g., Ca-carbonate, phyllosilicates) and organic molecules will be key to characterizing Bennu [3] prior to sample site selection. The goal of this study was to develop a suite of analog and meteorite samples and obtain their spectral properties over the wavelength ranges of OVIRS (0.4- 4.3 micrometer) and OTES (5.0-50 micrometer). These spectral data were used to validate the mission science-data processing system. We discuss the reasoning behind the study and share lessons learned.
The Crab pulsar light curve in the soft gamma ray range: FIGARO II results
NASA Technical Reports Server (NTRS)
Massaro, E.; Agrinier, B.; Barouch, E.; Comte, R.; Costa, E.; Cusumano, G. C.; Gerardi, G.; Lemoine, D.; Mandrou, P.; Masnou, J. L.
1992-01-01
The FIGARO II experiment (a large area, balloon borne, crystal scintillator detector working from 0.15 to 4.3 MeV) observed the Crab pulsar on 1990 Jul. 9 for about seven hours. The study of the pulse profile confirms some structures detected with a low significance during the shorter observation of 1986, and adds new important elements to the picture. In particular, between the two main peaks, two secondary peaks appear centered at phase values 0.1 and 0.3, in the energy range 0.38 to 0.49 MeV; in the same energy range, a spectral feature at 0.44 MeV, interpreted as a redshifted positron annihilation line, was observed during the same balloon flight in the phase interval including the second main peak and the neighboring secondary peak. If the phase interval considered is extended to include also the other secondary peak, the significance of the spectral line appears to increase.
Rapid determination of total protein and wet gluten in commercial wheat flour using siSVR-NIR.
Chen, Jia; Zhu, Shipin; Zhao, Guohua
2017-04-15
The determination of total protein and wet gluten is of critical importance when screening commercial flour for desired processing suitability. To this end, a near-infrared spectroscopy (NIR) method with support vector regression was developed in the present study. The effects of spectral preprocessing and the synergy interval on model performance were investigated. The results showed that the models from raw spectra were not acceptable, but they were substantially improved by properly applying spectral preprocessing methods. Meanwhile, the synergy interval was validated with a good ability to improve the performance of models based on the whole spectrum. The coefficient of determination (R 2 ), the root mean square error of prediction (RMSEP) and the standard deviation ratio (SDR) of the best models for total protein (wet gluten) were 0.906 (0.850), 0.425 (1.024) and 3.065 (2.482), respectively. These two best models have similar and lower relative errors (approximately 8.8%), which indicates their feasibility. Copyright © 2016 Elsevier Ltd. All rights reserved.
Circle-16QAM for a zero-guard-interval CO-OFDM system
NASA Astrophysics Data System (ADS)
Kong, Lingyu; Yang, Aiying; Guo, Peng; Lu, Yueming; Qiao, Yaojun
2018-01-01
In this paper, we introduce circle 16 quadrature amplitude modulation (C-16QAM) modulation format in a high spectral efficiency zero-guard-interval (ZGI) coherent optical (CO) orthogonal frequency-division multiplexing (OFDM) system. At transmitter, the C-16QAM has advantages over the conventional square 16QAM in terms of transmission distance and tolerance to laser linewidth and fiber nonlinearities. ZGI CO-OFDM enables to take away the cyclic prefix (CP), so it has the benefit of higher spectral efficiency compared with the conventional CO-OFDM system. At receiver, in order to compensate chromatic dispersion (CD) and phase noise in a single channel ZGI CO-OFDM system, we studied the overlapped frequency domain equalizer (OFDE) and two carrier phase recovery (CPR) algorithms. We simulate the above systems and the results demonstrate that with the C-16QAM, a 28GBaud ZGI CO-OFDM system can have the longer transmission distance, the higher tolerance to laser linewidth and fiber nonlinearities with contrast to the conventional square 16QAM.
NASA Astrophysics Data System (ADS)
Crockett, R. G. M.; Gillmore, G. K.
2009-04-01
During the second half of 2002, the University of Northampton Radon Research Group operated two continuous hourly-sampling radon detectors 2.25 km apart in Northampton, in the (English) East Midlands. This period included the Dudley earthquake (22/09/2002) which was widely noticed by members of the public in the Northampton area. Also, at various periods during 2008 the Group has operated another pair of continuous hourly-sampling radon detectors similar distances apart in Northampton. One such period included the Market Rasen earthquake (27/02/2008) which was also widely noticed by members of the public in the Northampton area. During each period of monitoring, two time-series of radon readings were obtained, one from each detector. These have been analysed for evidence of simultaneous similar anomalies: the premise being that big disturbances occurring at big distances (in relation to the detector separation) should produce simultaneous similar anomalies but that simultaneous anomalies occurring by chance will be dissimilar. As previously reported, cross-correlating the two 2002 time-series over periods of 1-30 days duration, rolled forwards through the time-series at one-hour intervals produced two periods of significant correlation, i.e. two periods of simultaneous similar behaviour in the radon concentrations. One of these periods corresponded in time to the Dudley earthquake, the other corresponded in time to a smaller earthquake which occurred in the English Channel (26/08/2002). We here report subsequent investigation of the 2002 time-series and the 2008 time-series using spectral-decomposition techniques. These techniques have revealed additional simultaneous similar behaviour in the two radon concentrations, not revealed by the rolling correlation on the raw data. These correspond in time to the Manchester earthquake swarm of October 2002 and the Market Rasen earthquake of February 2008. The spectral-decomposition techniques effectively ‘de-noise' the data, and also remove lower-frequency variations (e.g. tidal variations), revealing the simultaneous similarities. Whilst this is very much work in progress, there is the potential that such techniques enhance the possibility that simultaneous real-time monitoring of radon levels - for short-term simultaneous anomalies - at several locations in earthquake areas might provide the core of an earthquake prediction method. Keywords: Radon; earthquakes; time series; cross-correlation; spectral-decomposition; real-time simultaneous monitoring.
Interval sampling methods and measurement error: a computer simulation.
Wirth, Oliver; Slaven, James; Taylor, Matthew A
2014-01-01
A simulation study was conducted to provide a more thorough account of measurement error associated with interval sampling methods. A computer program simulated the application of momentary time sampling, partial-interval recording, and whole-interval recording methods on target events randomly distributed across an observation period. The simulation yielded measures of error for multiple combinations of observation period, interval duration, event duration, and cumulative event duration. The simulations were conducted up to 100 times to yield measures of error variability. Although the present simulation confirmed some previously reported characteristics of interval sampling methods, it also revealed many new findings that pertain to each method's inherent strengths and weaknesses. The analysis and resulting error tables can help guide the selection of the most appropriate sampling method for observation-based behavioral assessments. © Society for the Experimental Analysis of Behavior.
Surface microroughness of ion-beam etched optical surfaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Savvides, N.
2005-03-01
Ion-beam etching (IBE) and ion-beam figuring techniques using low-energy ion-beam sources have been applied for more than ten years in the fabrication and finishing of extremely smooth high-performance optics. We used optical interferometric techniques and atomic force microscopy to study the evolution of the surface root-mean-square (rms) microroughness, Rq, as a function of depth of a material removed (0-3000 nm) by a broad ion-beam source (Ar{sup +} ions of energy 600 eV and ion current density of 1 mA cm{sup -2}). Highly polished samples of fused silica and Zerodur (Rq{approx}3.5 A) showed a small decrease in microroughness (to 2.5 A)more » after 3000-nm IBE removal while an ultrapolished single-crystal sapphire sample (Rq{approx}1 A rms) retained its very low microroughness during IBE. Power spectral density functions over the spatial frequency interval of measurement (f=5x10{sup -3}-25 {mu}m{sup -1}) indicate that the IBE surfaces have minimal subsurface damage and low optical scatter.« less
a Preliminary Investigation on Comparison and Transformation of SENTINEL-2 MSI and Landsat 8 Oli
NASA Astrophysics Data System (ADS)
Chen, F.; Lou, S.; Fan, Q.; Li, J.; Wang, C.; Claverie, M.
2018-05-01
A PRELIMINARY INVESTIGATION ON COMPARISON AND TRANSFORMATION OF SENTINEL-2 MSI AND LANDSAT 8 OLI Timely and accurate earth observation with short revisit interval is usually necessary, especially for emergency response. Currently, several new generation sensors provided with similar channel characteristics have been operated onboard different satellite platforms, including Sentinel-2 and Landsat 8. Joint use of the observations by different sensors offers an opportunity to meet the demands for emergency requirements. For example, through the combination of Landsat and Sentinel-2 data, the land can be observed every 2-3 days at medium spatial resolution. However, differences are expected in radiometric values (e.g., channel reflectance) of the corresponding channels between two sensors. Spectral response function (SRF) is taken as an important aspect of sensor settings. Accordingly, between-sensor differences due to SRFs variation need to be quantified and compensated. The comparison of SRFs shows difference (more or less) in channel settings between Sentinel-2 Multi-Spectral Instrument (MSI) and Landsat 8 Operational Land Imager (OLI). Effect of the difference in SRF on corresponding values between MSI and OLI was investigated, mainly in terms of channel reflectance and several derived spectral indices. Spectra samples from ASTER Spectral Library Version 2.0 and Hyperion data archives were used in obtaining channel reflectance simulation of MSI and OLI. Preliminary results show that MSI and OLI are well comparable in several channels with small relative discrepancy (< 5 %), including the Costal Aerosol channel, a NIR (855-875 nm) channel, the SWIR channels, and the Cirrus channel. Meanwhile, for channels covering Blue, Green, Red, and NIR (785-900 nm), the between-sensor differences are significantly presented. Compared with the difference in reflectance of each individual channel, the difference in derived spectral index is more significant. In addition, effectiveness of linear transformation model is not ensured when the target belongs to another spectra collection. If an improper transformation model is selected, the between-sensor discrepancy will even largely increase. In conclusion, improvement in between-sensor consistency is possibly a challenge, through linear transformation based on model(s) generated from other spectra collections.
NASA Technical Reports Server (NTRS)
Rhyne, R. H.; Murrow, H. N.; Sidwell, K.
1976-01-01
Use of power spectral design techniques for supersonic transports requires accurate definition of atmospheric turbulence in the long wavelength region below the knee of the power spectral density function curve. Examples are given of data obtained from a current turbulence flight sampling program. These samples are categorized as (1) convective, (2) wind shear, (3) rotor, and (4) mountain-wave turbulence. Time histories, altitudes, root-mean-square values, statistical degrees of freedom, power spectra, and integral scale values are shown and discussed.
NASA Astrophysics Data System (ADS)
Penttilä, Antti; Martikainen, Julia; Gritsevich, Maria; Muinonen, Karri
2018-02-01
Meteorite samples are measured with the University of Helsinki integrating-sphere UV-vis-NIR spectrometer. The resulting spectra of 30 meteorites are compared with selected spectra from the NASA Planetary Data System meteorite spectra database. The spectral measurements are transformed with the principal component analysis, and it is shown that different meteorite types can be distinguished from the transformed data. The motivation is to improve the link between asteroid spectral observations and meteorite spectral measurements.
Meteorite-asteroid spectral comparison - The effects of comminution, melting, and recrystallization
NASA Technical Reports Server (NTRS)
Clark, Beth E.; Fanale, Fraser P.; Salisbury, John W.
1992-01-01
The present laboratory simulation of possible spectral-alteration effects on the optical surface of ordinary chondrite parent bodies duplicated regolith processes through comminution of the samples to finer rain sizes. After reflectance spectra characterization, the comminuted samples were melted, crystallized, recomminuted, and again characterized. While individual spectral characteristics could be significantly changed by these processes, no combination of the alteration procedures appeared capable of affecting all relevant parameters in a way that improved the match between chondritic meteorites and S-class asteroids.
Is Tridymite at Gale Crater Evidence for Silicic Volcanism on Mars?
NASA Technical Reports Server (NTRS)
Morris, Richard V.; Vaniman, David T.; Ming, Douglas W.; Graff, Trevor G.; Downs, Robert T.; Fendrich, Kim; Mertzman, Stanley A.
2016-01-01
The X-ray diffraction (XRD) instrument (CheMin) onboard the MSL rover Curiosity detected 17 wt% of the SiO2 polymorph tridymite (relative to bulk sample) for the Buckskin drill sample (73 wt% SiO2) obtained from sedimentary rock in the Murray formation at Gale Crater, Mars. Other detected crystalline materials are plagioclase, sanidine, cristobalite, cation-deficient magnetite, and anhydrite. XRD amorphous material constitutes approx. 60 wt% of bulk sample, and the position of its broad diffraction peak near approx. 26 deg. 2-theta is consistent with opal-A. Tridymite is a lowpressure, high-temperature mineral (approx. 870 to 1670 deg. C) whose XRD-identified occurrence on the Earth is usually associated with silicic (e.g., rhyolitic) volcanism. High SiO2 deposits have been detected at Gale crater by remote sensing from martian orbit and interpreted as opal-A on the basis H2O and Si-OH spectral features. Proposed opal-A formation pathways include precipitation of silica from lake waters and high-SiO2 residues of acid-sulfate leaching. Tridymite is nominally anhydrous and would not exhibit these spectral features. We have chemically and spectrally analyzed rhyolitic samples from New Mexico and Iwodake volcano (Japan). The glassy (by XRD) NM samples have H2O spectral features similar to opal-A. The Iwodake sample, which has been subjected to high-temperature acid sulfate leaching, also has H2O spectral features similar to opal-A. The Iwodake sample has approx. 98 wt% SiO2 and 1% wt% TiO2 (by XRF), tridymite (>80 wt.% of crystalline material without detectable quartz by XRD), and H2O and Si-OH spectral features. These results open the working hypothesis that the opal-A-like high-SiO2 deposits at Gale crater detected from martian orbit are products of alteration associated with silicic volcanism. The presence or absence of tridymite will depend on lava crystallization temperatures (NM) and post crystallization alteration temperatures (Iwodake).
Lavine, Barry K; White, Collin G; Allen, Matthew D; Fasasi, Ayuba; Weakley, Andrew
2016-10-01
A prototype library search engine has been further developed to search the infrared spectral libraries of the paint data query database to identify the line and model of a vehicle from the clear coat, surfacer-primer, and e-coat layers of an intact paint chip. For this study, search prefilters were developed from 1181 automotive paint systems spanning 3 manufacturers: General Motors, Chrysler, and Ford. The best match between each unknown and the spectra in the hit list generated by the search prefilters was identified using a cross-correlation library search algorithm that performed both a forward and backward search. In the forward search, spectra were divided into intervals and further subdivided into windows (which corresponds to the time lag for the comparison) within those intervals. The top five hits identified in each search window were compiled; a histogram was computed that summarized the frequency of occurrence for each library sample, with the IR spectra most similar to the unknown flagged. The backward search computed the frequency and occurrence of each line and model without regard to the identity of the individual spectra. Only those lines and models with a frequency of occurrence greater than or equal to 20% were included in the final hit list. If there was agreement between the forward and backward search results, the specific line and model common to both hit lists was always the correct assignment. Samples assigned to the same line and model by both searches are always well represented in the library and correlate well on an individual basis to specific library samples. For these samples, one can have confidence in the accuracy of the match. This was not the case for the results obtained using commercial library search algorithms, as the hit quality index scores for the top twenty hits were always greater than 99%. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Gausman, H. W.; Cardenas, R.; Berumen, A.
1974-01-01
Pepper and sorghum plants (characterized by porous and compact leaf mesophylls, respectively) were used to study the influence of leaf age on light reflectance. Measurements were limited to the upper five nodal positions within each growth stage, since upper leaves make up most of the reflectance surfaces remotely sensed. The increase in leaf thickness and water content with increasing leaf age was taken into consideration, since each of these factors affects the reflectance as well as the selection of spectral wavelength intervals for optimum discrimination of vegetation.
Hand-held radiometer red and photographic infrared spectral measurements of agricultural crops
NASA Technical Reports Server (NTRS)
Tucker, C. J.; Fan, C. J.; Elgin, J. H., Jr.; Mcmurtrey, J. E., III
1978-01-01
Red and photographic infrared radiance data, collected under a variety of conditions at weekly intervals throughout the growing season using a hand-held radiometer, were used to monitor crop growth and development. The vegetation index transformation was used to effectively compensate for the different irradiational conditions encountered during the study period. These data, plotted against time, compared the different crops measured by comparing their green leaf biomass dynamics. This approach, based entirely upon spectral inputs, closely monitors crop growth and development and indicates the promise of ground-based hand-held radiometer measurements of crops.
REDSPEC: NIRSPEC data reduction
NASA Astrophysics Data System (ADS)
Kim, S.; Prato, L.; McLean, I.
2015-07-01
REDSPEC is an IDL based reduction package designed with NIRSPEC in mind though can be used to reduce data from other spectrographs as well. REDSPEC accomplishes spatial rectification by summing an A+B pair of a calibration star to produce an image with two spectra; the image is remapped on the basis of polynomial fits to the spectral traces and calculation of gaussian centroids to define their separation, producing straight spectral traces with respect to the detector rows. The raw images are remapped onto a coordinate system with uniform intervals in spatial extent along the slit and in wavelength along the dispersion axis.
Infrared reflectance spectra (4-12 micron) of lunar samples
NASA Technical Reports Server (NTRS)
Nash, Douglas B.
1991-01-01
Presented here are infrared reflectance spectra of a typical set of Apollo samples to illustrate spectral character in the mid-infrared (4 to 12 microns) of lunar materials and how the spectra varies among three main forms: soil, breccia, and igneous rocks. Reflectance data, to a close approximation, are the inverse of emission spectra; thus, for a given material the spectral reflectance (R) at any given wavelength is related to emission (E) by 1 - R equals E. Therefore, one can use reflectance spectra of lunar samples to predict how emission spectra of material on the lunar surface will appear to spectrometers on orbiting spacecraft or earthbound telescopes. Spectra were measured in the lab in dry air using a Fourier Transform Infrared spectrometer. Shown here is only the key portion (4 to 12 microns) of each spectrum relating to the principal spectral emission region for sunlit lunar materials and to where the most diagnostic spectral features occur.
NASA Astrophysics Data System (ADS)
Rodríguez Castillo, Guillermo A.; Israel, Gian Luca; Tiengo, Andrea; Salvetti, David; Turolla, Roberto; Zane, Silvia; Rea, Nanda; Esposito, Paolo; Mereghetti, Sandro; Perna, Rosalba; Stella, Luigi; Pons, José A.; Campana, Sergio; Götz, Diego; Motta, Sara
2016-03-01
We study the timing and spectral properties of the low-magnetic field, transient magnetar SWIFT J1822.3-1606 as it approached quiescence. We coherently phase-connect the observations over a time-span of ˜500 d since the discovery of SWIFT J1822.3-1606 following the Swift-Burst Alert Telescope (BAT) trigger on 2011 July 14, and carried out a detailed pulse phase spectroscopy along the outburst decay. We follow the spectral evolution of different pulse phase intervals and find a phase and energy-variable spectral feature, which we interpret as proton cyclotron resonant scattering of soft photon from currents circulating in a strong (≳1014 G) small-scale component of the magnetic field near the neutron star surface, superimposed to the much weaker (˜3 × 1013 G) magnetic field. We discuss also the implications of the pulse-resolved spectral analysis for the emission regions on the surface of the cooling magnetar.
NASA Astrophysics Data System (ADS)
Geng, Yong; Huang, Xiatao; Cui, Wenwen; Ling, Yun; Xu, Bo; Zhang, Jin; Yi, Xingwen; Wu, Baojian; Huang, Shu-Wei; Qiu, Kun; Wong, Chee Wei; Zhou, Heng
2018-05-01
We demonstrate seamless channel multiplexing and high bitrate superchannel transmission of coherent optical orthogonal-frequency-division-multiplexing (CO-OFDM) data signals utilizing a dissipative Kerr soliton (DKS) frequency comb generated in an on-chip microcavity. Aided by comb line multiplication through Nyquist pulse modulation, the high stability and mutual coherence among mode-locked Kerr comb lines are exploited for the first time to eliminate the guard intervals between communication channels and achieve full spectral density bandwidth utilization. Spectral efficiency as high as 2.625 bit/Hz/s is obtained for 180 CO-OFDM bands encoded with 12.75 Gbaud 8-QAM data, adding up to total bitrate of 6.885 Tb/s within 2.295 THz frequency comb bandwidth. Our study confirms that high coherence is the key superiority of Kerr soliton frequency combs over independent laser diodes, as a multi-spectral coherent laser source for high-bandwidth high-spectral-density transmission networks.
Johnson, Michaela R.; Graham, Garth E.; Hubbard, Bernard E.; Benzel, William M.
2015-07-16
This Data Series summarizes results from July 2013 sampling in the western Alaska Range near Mount Estelle, Alaska. The fieldwork combined in situ and camp-based spectral measurements of talus/soil and rock samples. Five rock and 48 soil samples were submitted for quantitative geochemical analysis (for 55 major and trace elements), and the 48 soils samples were also analyzed by x-ray diffraction to establish mineralogy and geochemistry. The results and sample photographs are presented in a geodatabase that accompanies this report. The spectral, mineralogical, and geochemical characterization of these samples and the sites that they represent can be used to validate existing remote-sensing datasets (for example, ASTER) and future hyperspectral studies. Empirical evidence of jarosite (as identified by x-ray diffraction and spectral analysis) corresponding with gold concentrations in excess of 50 parts per billion in soil samples suggests that surficial mapping of jarosite in regional surveys may be useful for targeting areas of prospective gold occurrences in this sampling area.
NASA Astrophysics Data System (ADS)
Karami, Mojtaba; Rangzan, Kazem; Saberi, Azim
2013-10-01
With emergence of air-borne and space-borne hyperspectral sensors, spectroscopic measurements are gaining more importance in remote sensing. Therefore, the number of available spectral reference data is constantly increasing. This rapid increase often exhibits a poor data management, which leads to ultimate isolation of data on disk storages. Spectral data without precise description of the target, methods, environment, and sampling geometry cannot be used by other researchers. Moreover, existing spectral data (in case it accompanied with good documentation) become virtually invisible or unreachable for researchers. Providing documentation and a data-sharing framework for spectral data, in which researchers are able to search for or share spectral data and documentation, would definitely improve the data lifetime. Relational Database Management Systems (RDBMS) are main candidates for spectral data management and their efficiency is proven by many studies and applications to date. In this study, a new approach to spectral data administration is presented based on spatial identity of spectral samples. This method benefits from scalability and performance of RDBMS for storage of spectral data, but uses GIS servers to provide users with interactive maps as an interface to the system. The spectral files, photographs and descriptive data are considered as belongings of a geospatial object. A spectral processing unit is responsible for evaluation of metadata quality and performing routine spectral processing tasks for newly-added data. As a result, by using internet browser software the users would be able to visually examine availability of data and/or search for data based on descriptive attributes associated to it. The proposed system is scalable and besides giving the users good sense of what data are available in the database, it facilitates participation of spectral reference data in producing geoinformation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nguyen, Hieu T., E-mail: hieu.nguyen@anu.edu.au; Macdonald, Daniel; Baker-Finch, Simeon C.
2014-03-17
The radiative recombination coefficient B(T) in crystalline silicon is determined for the temperature range 90–363 K, and in particular from 270 to 350 K with an interval of 10 K, where only sparse data are available at present. The band-band absorption coefficient established recently by Nguyen et al. [J. Appl. Phys. 115, 043710 (2014)] via photoluminescence spectrum measurements is employed to compute the values of B(T) at various temperatures. The results agree very well with literature data from Trupke et al. [J. Appl. Phys. 94, 4930 (2003).] We present a polynomial parameterization describing the temperature dependence of the product of B(T) and themore » square of the intrinsic carrier density. We also find that B(T) saturates at a near constant value at room temperature and above for silicon samples with relatively low free carrier densities.« less
NASA Astrophysics Data System (ADS)
Liu, Wei; Sneeuw, Nico; Jiang, Weiping
2017-04-01
GRACE mission has contributed greatly to the temporal gravity field monitoring in the past few years. However, ocean tides cause notable alias errors for single-pair spaceborne gravimetry missions like GRACE in two ways. First, undersampling from satellite orbit induces the aliasing of high-frequency tidal signals into the gravity signal. Second, ocean tide models used for de-aliasing in the gravity field retrieval carry errors, which will directly alias into the recovered gravity field. GRACE satellites are in non-repeat orbit, disabling the alias error spectral estimation based on the repeat period. Moreover, the gravity field recovery is conducted in non-strictly monthly interval and has occasional gaps, which result in an unevenly sampled time series. In view of the two aspects above, we investigate the data-driven method to mitigate the ocean tide alias error in a post-processing mode.
Quantitative determination of Auramine O by terahertz spectroscopy with 2DCOS-PLSR model
NASA Astrophysics Data System (ADS)
Zhang, Huo; Li, Zhi; Chen, Tao; Qin, Binyi
2017-09-01
Residues of harmful dyes such as Auramine O (AO) in herb and food products threaten the health of people. So, fast and sensitive detection techniques of the residues are needed. As a powerful tool for substance detection, terahertz (THz) spectroscopy was used for the quantitative determination of AO by combining with an improved partial least-squares regression (PLSR) model in this paper. Absorbance of herbal samples with different concentrations was obtained by THz-TDS in the band between 0.2THz and 1.6THz. We applied two-dimensional correlation spectroscopy (2DCOS) to improve the PLSR model. This method highlighted the spectral differences of different concentrations, provided a clear criterion of the input interval selection, and improved the accuracy of detection result. The experimental result indicated that the combination of the THz spectroscopy and 2DCOS-PLSR is an excellent quantitative analysis method.
Visible and shortwave infrared focal planes for remote sensing instruments
NASA Astrophysics Data System (ADS)
Tower, J. R.; McCarthy, B. M.; Pellon, L. E.; Strong, R. T.; Elabd, H.
1984-01-01
The development of solid-state sensor technology for multispectral linear array (MLA) instruments is described. A buttable four-spectral-band linear-format CCD and a buttable two-spectral band linear-format short-wave IR CCD have been designed, and first samples have been demonstrated. In addition, first-sample four-band interference filters have been fabricated, and hybrid packaging technology is being developed. Based on this development work, the design and construction of focal planes for a Shuttle sortie MLA instrument have begun. This work involves a visible and near-IR focal plane with 2048 pixels x 4 spectral bands and a short-wave IR focal plane with 1024 pixels x 2 spectral bands.
NASA Astrophysics Data System (ADS)
Godsey, S. E.; Kirchner, J. W.
2008-12-01
The mean residence time - the average time that it takes rainfall to reach the stream - is a basic parameter used to characterize catchment processes. Heterogeneities in these processes lead to a distribution of travel times around the mean residence time. By examining this travel time distribution, we can better predict catchment response to contamination events. A catchment system with shorter residence times or narrower distributions will respond quickly to contamination events, whereas systems with longer residence times or longer-tailed distributions will respond more slowly to those same contamination events. The travel time distribution of a catchment is typically inferred from time series of passive tracers (e.g., water isotopes or chloride) in precipitation and streamflow. Variations in the tracer concentration in streamflow are usually damped compared to those in precipitation, because precipitation inputs from different storms (with different tracer signatures) are mixed within the catchment. Mathematically, this mixing process is represented by the convolution of the travel time distribution and the precipitation tracer inputs to generate the stream tracer outputs. Because convolution in the time domain is equivalent to multiplication in the frequency domain, it is relatively straightforward to estimate the parameters of the travel time distribution in either domain. In the time domain, the parameters describing the travel time distribution are typically estimated by maximizing the goodness of fit between the modeled and measured tracer outputs. In the frequency domain, the travel time distribution parameters can be estimated by fitting a power-law curve to the ratio of precipitation spectral power to stream spectral power. Differences between the methods of parameter estimation in the time and frequency domain mean that these two methods may respond differently to variations in data quality, record length and sampling frequency. Here we evaluate how well these two methods of travel time parameter estimation respond to different sources of uncertainty and compare the methods to one another. We do this by generating synthetic tracer input time series of different lengths, and convolve these with specified travel-time distributions to generate synthetic output time series. We then sample both the input and output time series at various sampling intervals and corrupt the time series with realistic error structures. Using these 'corrupted' time series, we infer the apparent travel time distribution, and compare it to the known distribution that was used to generate the synthetic data in the first place. This analysis allows us to quantify how different record lengths, sampling intervals, and error structures in the tracer measurements affect the apparent mean residence time and the apparent shape of the travel time distribution.
NASA Astrophysics Data System (ADS)
Riu, Lucie; Bibring, Jean-Pierre; Pilorget, Cédric; Poulet, François; Hamm, Vincent
2018-03-01
The miniaturized near-infrared hyperspectral microscope MicrOmega, on board the MASCOT lander for Hayabusa-2 mission, is designed to perform in situ measurements at the grain scale of the C-type asteroid 1999 JU3 RYUGU. MicrOmega will observe samples with a field of view of a few millimeters with a spatial sampling of 25 μm and acquire near-infrared spectra by illuminating the sample sequentially with different wavelengths from 0.99 to 3.55 μm over two spectral channels with a typical spectral sampling of 20 cm-1. The on-ground calibration of MicrOmega requires a full characterization of the nominal range of operation of the instrument, both spectral (0.99-3.55 μm) and thermal (-40 °C to +40 °C) to derive the radiometric and spectral responses combined into a 4D transfer function to convert raw signal to calibrated reflectance. This specific 4D radiometric reference gives the instrument response according to the pixel location (x,y), the wavelength and the instrument temperature. This paper reports the complex computation of the 4D radiometric reference for the 0.9-2.5 μm channel. In this spectral range, the composition of the grains of a wide variety of minerals with relevance to solar system bodies can be identified through diagnostic spectral features: mafic (pyroxene, olivine…) as well as hydrated and altered minerals that are key phases for the solar system bodies' exploration.
Classification of river water pollution using Hyperion data
NASA Astrophysics Data System (ADS)
Kar, Soumyashree; Rathore, V. S.; Champati ray, P. K.; Sharma, Richa; Swain, S. K.
2016-06-01
A novel attempt is made to use hyperspectral remote sensing to identify the spatial variability of metal pollutants present in river water. It was also attempted to classify the hyperspectral image - Earth Observation-1 (EO-1) Hyperion data of an 8 km stretch of the river Yamuna, near Allahabad city in India depending on its chemical composition. For validating image analysis results, a total of 10 water samples were collected and chemically analyzed using Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES). Two different spectral libraries from field and image data were generated for the 10 sample locations. Advanced per-pixel supervised classifications such as Spectral Angle Mapper (SAM), SAM target finder using BandMax and Support Vector Machine (SVM) were carried out along with the unsupervised clustering procedure - Iterative Self-Organizing Data Analysis Technique (ISODATA). The results were compared and assessed with respect to ground data. Analytical Spectral Devices (ASD), Inc. spectroradiometer, FieldSpec 4 was used to generate the spectra of the water samples which were compiled into a spectral library and used for Spectral Absorption Depth (SAD) analysis. The spectral depth pattern of image and field spectral libraries was found to be highly correlated (correlation coefficient, R2 = 0.99) which validated the image analysis results with respect to the ground data. Further, we carried out a multivariate regression analysis to assess the varying concentrations of metal ions present in water based on the spectral depth of the corresponding absorption feature. Spectral Absorption Depth (SAD) analysis along with metal analysis of field data revealed the order in which the metals affected the river pollution, which was in conformity with the findings of Central Pollution Control Board (CPCB). Therefore, it is concluded that hyperspectral imaging provides opportunity that can be used for satellite based remote monitoring of water quality from space.
Matched spectral filter based on reflection holograms for analyte identification.
Cao, Liangcai; Gu, Claire
2009-12-20
A matched spectral filter set that provides automatic preliminary analyte identification is proposed and analyzed. Each matched spectral filter in the set containing the multiple spectral peaks corresponding to the Raman spectrum of a substance is capable of collecting the specified spectrum into the detector simultaneously. The filter set is implemented by multiplexed volume holographic reflection gratings. The fabrication of a matched spectral filter in an Fe:LiNbO(3) crystal is demonstrated to match the Raman spectrum of the sample Rhodamine 6G (R6G). An interference alignment method is proposed and used in the fabrication to ensure that the multiplexed gratings are in the same direction at a high angular accuracy of 0.0025 degrees . Diffused recording beams are used to control the bandwidth of the spectral peaks. The reflection spectrum of the filter is characterized using a modified Raman spectrometer. The result of the filter's reflection spectrum matches that of the sample R6G. A library of such matched spectral filters will facilitate a fast detection with a higher sensitivity and provide a capability for preliminary molecule identification.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Valenta, J., E-mail: jan.valenta@mff.cuni.cz; Greben, M.
2015-04-15
Application capabilities of optical microscopes and microspectroscopes can be considerably enhanced by a proper calibration of their spectral sensitivity. We propose and demonstrate a method of relative and absolute calibration of a microspectroscope over an extraordinary broad spectral range covered by two (parallel) detection branches in visible and near-infrared spectral regions. The key point of the absolute calibration of a relative spectral sensitivity is application of the standard sample formed by a thin layer of Si nanocrystals with stable and efficient photoluminescence. The spectral PL quantum yield and the PL spatial distribution of the standard sample must be characterized bymore » separate experiments. The absolutely calibrated microspectroscope enables to characterize spectral photon emittance of a studied object or even its luminescence quantum yield (QY) if additional knowledge about spatial distribution of emission and about excitance is available. Capabilities of the calibrated microspectroscope are demonstrated by measuring external QY of electroluminescence from a standard poly-Si solar-cell and of photoluminescence of Er-doped Si nanocrystals.« less
NASA Technical Reports Server (NTRS)
Brunner, H.; Worrall, D. M.; Wilkes, Belinda J.; Elvis, Martin
1989-01-01
The dependence of the soft X-ray spectral slope on radio, optical and X-ray properties, and on redshift are reported for a large sample of Active Galactic Nuclei (AGN). The sample includes 317 optically and radio-selected AGN from a preliminary version of the Einstein Imaging Proportional Counter (IPC) quasar and AGN data base. The main results are: the difference in X-ray slope between radio-loud and radio-quiet AGN were confirmed for an independent and much larger sample of sources; a difference in X-ray slope between flat and steep radio spectrum AGN is observed only in high luminosity sub-sample; in flat radio spectrum AGNs there is an indication for a dependence of the X-ray spectral index on X-ray luminosity redshift and alpha sub 0x.
Spectral Learning for Supervised Topic Models.
Ren, Yong; Wang, Yining; Zhu, Jun
2018-03-01
Supervised topic models simultaneously model the latent topic structure of large collections of documents and a response variable associated with each document. Existing inference methods are based on variational approximation or Monte Carlo sampling, which often suffers from the local minimum defect. Spectral methods have been applied to learn unsupervised topic models, such as latent Dirichlet allocation (LDA), with provable guarantees. This paper investigates the possibility of applying spectral methods to recover the parameters of supervised LDA (sLDA). We first present a two-stage spectral method, which recovers the parameters of LDA followed by a power update method to recover the regression model parameters. Then, we further present a single-phase spectral algorithm to jointly recover the topic distribution matrix as well as the regression weights. Our spectral algorithms are provably correct and computationally efficient. We prove a sample complexity bound for each algorithm and subsequently derive a sufficient condition for the identifiability of sLDA. Thorough experiments on synthetic and real-world datasets verify the theory and demonstrate the practical effectiveness of the spectral algorithms. In fact, our results on a large-scale review rating dataset demonstrate that our single-phase spectral algorithm alone gets comparable or even better performance than state-of-the-art methods, while previous work on spectral methods has rarely reported such promising performance.
NASA Astrophysics Data System (ADS)
Jayashri, T. A.; Krishnan, G.; Rema Rani, N.
2014-12-01
Tris(1,2-diaminoethane)nickel(II)sulphate was prepared, and characterised by various chemical and spectral techniques. The sample was irradiated with 60Co gamma rays for varying doses. Sulphite ion and ammonia were detected and estimated in the irradiated samples. Non-isothermal decomposition kinetics, X-ray diffraction pattern, Fourier transform infrared spectroscopy, electronic, fast atom bombardment mass spectra, and surface morphology of the complex were studied before and after irradiation. Kinetic parameters were evaluated by integral, differential, and approximation methods. Irradiation enhanced thermal decomposition, lowering thermal and kinetic parameters. The mechanism of decomposition is controlled by R3 function. From X-ray diffraction studies, change in lattice parameters and subsequent changes in unit cell volume and average crystallite size were observed. Both unirradiated and irradiated samples of the complex belong to trigonal crystal system. Decrease in the intensity of the peaks was observed in the infrared spectra of irradiated samples. Electronic spectral studies revealed that the M-L interaction is unaffected by irradiation. Mass spectral studies showed that the fragmentation patterns of the unirradiated and irradiated samples are similar. The additional fragment with m/z 256 found in the irradiated sample is attributed to S8+. Surface morphology of the complex changed upon irradiation.
Infrared (IR) photon-sensitive spectromicroscopy in a cryogenic environment
Pereverzev, Sergey
2016-06-14
A system designed to suppress thermal radiation background and to allow IR single-photon sensitive spectromicroscopy of small samples by using both absorption, reflection, and emission/luminescence measurements. The system in one embodiment includes: a light source; a plurality of cold mirrors configured to direct light along a beam path; a cold or warm sample holder in the beam path; windows of sample holder (or whole sample holder) are transparent in a spectral region of interest, so they do not emit thermal radiation in the same spectral region of interest; a cold monochromator or other cold spectral device configured to direct a selected fraction of light onto a cold detector; a system of cold apertures and shields positioned along the beam path to prevent unwanted thermal radiation from arriving at the cold monochromator and/or the detector; a plurality of optical, IR and microwave filters positioned along the beam path and configured to adjust a spectral composition of light incident upon the sample under investigation and/or on the detector; a refrigerator configured to maintain the detector at a temperature below 1.0K; and an enclosure configured to: thermally insulate the light source, the plurality of mirrors, the sample holder, the cold monochromator and the refrigerator.
Analyte-induced spectral filtering in femtosecond transient absorption spectroscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abraham, Baxter; Nieto-Pescador, Jesus; Gundlach, Lars
Here, we discuss the influence of spectral filtering by samples in femtosecond transient absorption measurements. Commercial instruments for transient absorption spectroscopy (TA) have become increasingly available to scientists in recent years and TA is becoming an established technique to measure the dynamics of photoexcited systems. Furthermore, we show that absorption of the excitation pulse by the sample can severely alter the spectrum and consequently the temporal pulse shape. This “spectral self-filtering” effect can lead to systematic errors and misinterpretation of data, most notably in concentration dependent measurements. Finally, the combination of narrow absorption peaks in the sample with ultrafast broadbandmore » excitation pulses is especially prone to this effect.« less
NASA Astrophysics Data System (ADS)
Jiang, Kaili; Zhu, Jun; Tang, Bin
2017-12-01
Periodic nonuniform sampling occurs in many applications, and the Nyquist folding receiver (NYFR) is an efficient, low complexity, and broadband spectrum sensing architecture. In this paper, we first derive that the radio frequency (RF) sample clock function of NYFR is periodic nonuniform. Then, the classical results of periodic nonuniform sampling are applied to NYFR. We extend the spectral reconstruction algorithm of time series decomposed model to the subsampling case by using the spectrum characteristics of NYFR. The subsampling case is common for broadband spectrum surveillance. Finally, we take example for a LFM signal under large bandwidth to verify the proposed algorithm and compare the spectral reconstruction algorithm with orthogonal matching pursuit (OMP) algorithm.
Analyte-induced spectral filtering in femtosecond transient absorption spectroscopy
Abraham, Baxter; Nieto-Pescador, Jesus; Gundlach, Lars
2017-03-06
Here, we discuss the influence of spectral filtering by samples in femtosecond transient absorption measurements. Commercial instruments for transient absorption spectroscopy (TA) have become increasingly available to scientists in recent years and TA is becoming an established technique to measure the dynamics of photoexcited systems. Furthermore, we show that absorption of the excitation pulse by the sample can severely alter the spectrum and consequently the temporal pulse shape. This “spectral self-filtering” effect can lead to systematic errors and misinterpretation of data, most notably in concentration dependent measurements. Finally, the combination of narrow absorption peaks in the sample with ultrafast broadbandmore » excitation pulses is especially prone to this effect.« less
NASA Astrophysics Data System (ADS)
Pan, C.; Rogers, D.
2012-12-01
Characterizing the thermal infrared (TIR) spectral mixing behavior of compacted fine-grained mineral assemblages is necessary for facilitating quantitative mineralogy of sedimentary surfaces from spectral measurements. Previous researchers have demonstrated that TIR spectra from igneous and metamorphic rocks as well as coarse-grained (>63 micron) sand mixtures combine in proportion to their volume abundance. However, the spectral mixing behavior of compacted, fine-grained mineral mixtures that would be characteristic of sedimentary depositional environments has received little attention. Here we characterize the spectral properties of pressed pellet samples of <10 micron mineral mixtures to 1) assess linearity of spectral combinations, 2) determine whether there are consistent over- or under-estimations of different types of minerals in spectral models and 3) determine if model accuracy can be improved by including both fine- and coarse-grained end-members. Major primary and secondary minerals found on the Martian surface including feldspar, pyroxene, smectite, sulfate and carbonate were crushed with an agate mortar and pestle and centrifuged to obtain less than 10 micron size. Pure phases and mixtures of two, three and four components were made in varying proportions by volume. All of the samples were pressed into pellets at 15000PSI to minimize volume scattering. Thermal infrared spectra of pellets were measured in the Vibrational Spectroscopy Laboratory at Stony Brook University with a Thermo Fisher Nicolet 6700 Fourier transform infrared Michelson interferometer from ~225 to 2000 cm-1. Our preliminary results indicate that some pelletized samples have contributions from volume scattering, which leads to non-linear spectral combinations. It is not clear if the transparency features (which arise from multiple surface reflections of incident photons) are due to minor clinging fines on an otherwise specular pellet surface or to partially transmitted energy through optically thin grains in the compacted mixture. Inclusion of loose powder (<10 μm) sample spectra improves mineral abundance estimates for some mixtures. In general, mineral abundances are predicted to within +/- 10% (absolute) for approximately 60% of our samples; thus far, there are no clear trends in which cases produce better model results. With the exception of pyroxene/feldspar ratios being consistently overestimated, there are no consistent trends in over- or under-estimation of minerals. The results described here are based on the unsubstantiated assumption that areal abundance on the pellet surface is equal to the volume abundance. Thus future work will include micro-imaging of our samples to constrain areal abundance. We will also prepareclay mixtures using a wetting/drying sequence rather than pressure, and expand our set of samples to include additional mixture combinations to further characterize the spectral behavior of compacted mixtures. This work will be directly applicable to analysis of TES and Mini-TES data of lithified sedimentary deposits.
NASA Astrophysics Data System (ADS)
Wright, D. M.; Yeoman, T. K.; Woodfield, E. E.
2003-12-01
It is now a common practice to employ ground-based radars in order to distinguish between those regions of the Earth's upper atmosphere which are magnetically conjugate to open and closed field lines. Radar returns from ionospheric irregularities inside the polar cap and cusp regions generally exhibit large spectral widths in contrast to those which exist on closed field lines at lower latitudes. It has been suggested that the so-called Spectral Width Boundary (SWB) might act as a proxy for the open-closed field line boundary (OCFLB), which would then be an invaluable tool for investigating reconnection rates in the magnetosphere. The exact cause of the increased spectral widths observed at very high latitudes is still subject to considerable debate. Several mechanisms have been proposed. This paper compares a dusk-sector interval of coherent HF radar data with measurements made by an induction coil magnetometer located at Tromso, Norway (66° N geomagnetic). On this occasion, a series of transient regions of radar backscatter exhibiting large spectral widths are accompanied by increases in spectral power of ULF waves in the Pc1-2 frequency band. These observations would then, seem to support the possibility that high frequency magnetospheric wave activity at least contribute to the observed spectral characteristics and that such wave activity might play a significant role in the cusp and polar cap ionospheres.
NASA Technical Reports Server (NTRS)
Gross, S. H.
1981-01-01
The ASTP Doppler data were recalibrated, analyzed and related to geophysical phenomena and found consistent. Spectra were computed for data intervals covering each hemisphere. As many as 14 such intervals were analyzed. Wave structure is seen in much of the data. The spectra for all those intervals are very similar in a number of respects. They all decrease with frequency, or with decreasing wavelength. Power law fits are reasonable and spectral indices are found to range from about -2.0 to about -3.5. Both large scale (thousands of kilometers) and medium scale (hundreds of kilometers) waves are evident. These spectra are very similar to spectra of in situ measurements of neutrals and ionization measured by Atmosphere Explorer C.
Bautista, Pinky A; Yagi, Yukako
2011-01-01
In this paper we introduced a digital staining method for histopathology images captured with an n-band multispectral camera. The method consisted of two major processes: enhancement of the original spectral transmittance and the transformation of the enhanced transmittance to its target spectral configuration. Enhancement is accomplished by shifting the original transmittance with the scaled difference between the original transmittance and the transmittance estimated with m dominant principal component (PC) vectors;the m-PC vectors were determined from the transmittance samples of the background image. Transformation of the enhanced transmittance to the target spectral configuration was done using an nxn transformation matrix, which was derived by applying a least square method to the enhanced and target spectral training data samples of the different tissue components. Experimental results on the digital conversion of a hematoxylin and eosin (H&E) stained multispectral image to its Masson's trichrome stained (MT) equivalent shows the viability of the method.
High-angular-resolution stellar imaging with occultations from the Cassini spacecraft - III. Mira
NASA Astrophysics Data System (ADS)
Stewart, Paul N.; Tuthill, Peter G.; Nicholson, Philip D.; Hedman, Matthew M.
2016-04-01
We present an analysis of spectral and spatial data of Mira obtained by the Cassini spacecraft, which not only observed the star's spectra over a broad range of near-infrared wavelengths, but was also able to obtain high-resolution spatial information by watching the star pass behind Saturn's rings. The observed spectral range of 1-5 microns reveals the stellar atmosphere in the crucial water-bands which are unavailable to terrestrial observers, and the simultaneous spatial sampling allows the origin of spectral features to be located in the stellar environment. Models are fitted to the data, revealing the spectral and spatial structure of molecular layers surrounding the star. High-resolution imagery is recovered revealing the layered and asymmetric nature of the stellar atmosphere. The observational data set is also used to confront the state-of-the-art cool opacity-sampling dynamic extended atmosphere models of Mira variables through a detailed spectral and spatial comparison, revealing in general a good agreement with some specific departures corresponding to particular spectral features.
[Study on Application of NIR Spectral Information Screening in Identification of Maca Origin].
Wang, Yuan-zhong; Zhao, Yan-li; Zhang, Ji; Jin, Hang
2016-02-01
Medicinal and edible plant Maca is rich in various nutrients and owns great medicinal value. Based on near infrared diffuse reflectance spectra, 139 Maca samples collected from Peru and Yunnan were used to identify their geographical origins. Multiplication signal correction (MSC) coupled with second derivative (SD) and Norris derivative filter (ND) was employed in spectral pretreatment. Spectrum range (7,500-4,061 cm⁻¹) was chosen by spectrum standard deviation. Combined with principal component analysis-mahalanobis distance (PCA-MD), the appropriate number of principal components was selected as 5. Based on the spectrum range and the number of principal components selected, two abnormal samples were eliminated by modular group iterative singular sample diagnosis method. Then, four methods were used to filter spectral variable information, competitive adaptive reweighted sampling (CARS), monte carlo-uninformative variable elimination (MC-UVE), genetic algorithm (GA) and subwindow permutation analysis (SPA). The spectral variable information filtered was evaluated by model population analysis (MPA). The results showed that RMSECV(SPA) > RMSECV(CARS) > RMSECV(MC-UVE) > RMSECV(GA), were 2. 14, 2. 05, 2. 02, and 1. 98, and the spectral variables were 250, 240, 250 and 70, respectively. According to the spectral variable filtered, partial least squares discriminant analysis (PLS-DA) was used to build the model, with random selection of 97 samples as training set, and the other 40 samples as validation set. The results showed that, R²: GA > MC-UVE > CARS > SPA, RMSEC and RMSEP: GA < MC-UVE < CARS
Temporal Coding of Volumetric Imagery
NASA Astrophysics Data System (ADS)
Llull, Patrick Ryan
'Image volumes' refer to realizations of images in other dimensions such as time, spectrum, and focus. Recent advances in scientific, medical, and consumer applications demand improvements in image volume capture. Though image volume acquisition continues to advance, it maintains the same sampling mechanisms that have been used for decades; every voxel must be scanned and is presumed independent of its neighbors. Under these conditions, improving performance comes at the cost of increased system complexity, data rates, and power consumption. This dissertation explores systems and methods capable of efficiently improving sensitivity and performance for image volume cameras, and specifically proposes several sampling strategies that utilize temporal coding to improve imaging system performance and enhance our awareness for a variety of dynamic applications. Video cameras and camcorders sample the video volume (x,y,t) at fixed intervals to gain understanding of the volume's temporal evolution. Conventionally, one must reduce the spatial resolution to increase the framerate of such cameras. Using temporal coding via physical translation of an optical element known as a coded aperture, the compressive temporal imaging (CACTI) camera emonstrates a method which which to embed the temporal dimension of the video volume into spatial (x,y) measurements, thereby greatly improving temporal resolution with minimal loss of spatial resolution. This technique, which is among a family of compressive sampling strategies developed at Duke University, temporally codes the exposure readout functions at the pixel level. Since video cameras nominally integrate the remaining image volume dimensions (e.g. spectrum and focus) at capture time, spectral (x,y,t,lambda) and focal (x,y,t,z) image volumes are traditionally captured via sequential changes to the spectral and focal state of the system, respectively. The CACTI camera's ability to embed video volumes into images leads to exploration of other information within that video; namely, focal and spectral information. The next part of the thesis demonstrates derivative works of CACTI: compressive extended depth of field and compressive spectral-temporal imaging. These works successfully show the technique's extension of temporal coding to improve sensing performance in these other dimensions. Geometrical optics-related tradeoffs, such as the classic challenges of wide-field-of-view and high resolution photography, have motivated the development of mulitscale camera arrays. The advent of such designs less than a decade ago heralds a new era of research- and engineering-related challenges. One significant challenge is that of managing the focal volume (x,y,z ) over wide fields of view and resolutions. The fourth chapter shows advances on focus and image quality assessment for a class of multiscale gigapixel cameras developed at Duke. Along the same line of work, we have explored methods for dynamic and adaptive addressing of focus via point spread function engineering. We demonstrate another form of temporal coding in the form of physical translation of the image plane from its nominal focal position. We demonstrate this technique's capability to generate arbitrary point spread functions.
Jovian thundercloud observation with Jovian orbiter and ground-based telescope
NASA Astrophysics Data System (ADS)
Takahashi, Yukihiro; Nakajima, Kensuke; Takeuchi, Satoru; Sato, Mitsuteru; Fukuhara, Tetsuya; Watanabe, Makoto; Yair, Yoav; Fischer, Georg; Aplin, Karen
The latest observational and theoretical studies suggest that thunderstorms in Jupiter's at-mosphere are very important subject not only for understanding of meteorology, which may determine the large scale structures such as belt/zone and big ovals, but also for probing the water abundance of the deep atmosphere, which is crucial to constrain the behavior of volatiles in early solar system. Here we suggest a very simple high-speed imager on board Jovian orbiter, Optical Lightning Detector, OLD, optimized for detecting optical emissions from lightning dis-charge in Jupiter. OLD consists of radiation-tolerant CMOS sensors and two H Balmer Alpha line (656.3nm) filters. In normal sampling mode the frame intervals is 29ms with a full frame format of 512x512 pixels and in high-speed sampling mode the interval could be reduced down to 0.1ms by concentrating a limited area of 30x30 pixels. Weight, size and power consump-tion are about 1kg, 16x7x5.5 cm (sensor) and 16x12x4 cm (circuit), and 4W, respectively, though they can be reduced according to the spacecraft resources and required environmental tolerance. Also we plan to investigate the optical flashes using a ground-based middle-sized telescope, which will be built by Hokkaido University, with narrow-band high speed imaging unit using an EM-CCD camera. Observational strategy with these optical lightning detectors and spectral imagers, which enables us to estimate the horizontal motion and altitude of clouds, will be introduced.
NASA Technical Reports Server (NTRS)
Takeda, H.; Yamaguchi, A.; Hiroi, T.; Nyquist, L. E.; Shih, C.-Y.; Ohtake, M.; Karouji, Y.; Kobayashi, S.
2011-01-01
Anorthosites composed of nearly pure anorthite (PAN) at many locations in the farside highlands have been observed by the Kaguya multiband imager and spectral profiler [1]. Mineralogical studies of lunar meteorites of the Dhofar 489 group [2,3] and Yamato (Y-) 86032 [4], all possibly from the farside highlands, showed some aspects of the farside crust. Nyquist et al. [5] performed Sm-Nd and Ar-Ar studies of pristine ferroan anorthosites (FANs) of the returned Apollo samples and of Dhofar 908 and 489, and discussed implications for lunar crustal history. Nyquist et al. [6] reported initial results of a combined mineralogical/chronological study of the Yamato (Y-) 980318 cumulate eucrite with a conventional Sm-Nd age of 4567 24 Ma and suggested that all eucrites, including cumulate eucrites, crystallized from parental magmas within a short interval following differentiation of their parent body, and most eucrites participated in an event or events in the time interval 4400- 4560 Ma in which many isotopic systems were partially reset. During the foregoing studies, we recognized that variations in mineralogy and chronology of lunar anorthosites are more complex than those of the crustal materials of the HED parent body. In this study, we compared the mineralogies and reflectance spectra of the cumulate eucrites, Y-980433 and 980318, to those of the Dhofar 307 lunar meteorite of the Dhofar 489 group [2]. Here we consider information from these samples to gain a better understanding of the feldspathic farside highlands and the Vesta-like body.
Spectral identification and quantification of salts in the Atacama Desert
NASA Astrophysics Data System (ADS)
Harris, J. K.; Cousins, C. R.; Claire, M. W.
2016-10-01
Salt minerals are an important natural resource. The ability to quickly and remotely identify and quantify salt deposits and salt contaminated soils and sands is therefore a priority goal for the various industries and agencies that utilise salts. The advent of global hyperspectral imagery from instruments such as Hyperion on NASA's Earth-Observing 1 satellite has opened up a new source of data that can potentially be used for just this task. This study aims to assess the ability of Visible and Near Infrared (VNIR) spectroscopy to identify and quantify salt minerals through the use of spectral mixture analysis. The surface and near-surface soils of the Atacama Desert in Chile contain a variety of well-studied salts, which together with low cloud coverage, and high aridity, makes this region an ideal testbed for this technique. Two forms of spectral data ranging 0.35 - 2.5 μm were collected: laboratory spectra acquired using an ASD FieldSpec Pro instrument on samples from four locations in the Atacama desert known to have surface concentrations of sulfates, nitrates, chlorides and perchlorates; and images from the EO-1 satellite's Hyperion instrument taken over the same four locations. Mineral identifications and abundances were confirmed using quantitative XRD of the physical samples. Spectral endmembers were extracted from within the laboratory and Hyperion spectral datasets and together with additional spectral library endmembers fed into a linear mixture model. The resulting identification and abundances from both dataset types were verified against the sample XRD values. Issues of spectral scale, SNR and how different mineral spectra interact are considered, and the utility of VNIR spectroscopy and Hyperion in particular for mapping specific salt concentrations in desert environments is established. Overall, SMA was successful at estimating abundances of sulfate minerals, particularly calcium sulfate, from both hyperspectral image and laboratory sample spectra, while abundance estimation of other salt phase spectral end-members was achieved with a higher degree of error.
Data series embedding and scale invariant statistics.
Michieli, I; Medved, B; Ristov, S
2010-06-01
Data sequences acquired from bio-systems such as human gait data, heart rate interbeat data, or DNA sequences exhibit complex dynamics that is frequently described by a long-memory or power-law decay of autocorrelation function. One way of characterizing that dynamics is through scale invariant statistics or "fractal-like" behavior. For quantifying scale invariant parameters of physiological signals several methods have been proposed. Among them the most common are detrended fluctuation analysis, sample mean variance analyses, power spectral density analysis, R/S analysis, and recently in the realm of the multifractal approach, wavelet analysis. In this paper it is demonstrated that embedding the time series data in the high-dimensional pseudo-phase space reveals scale invariant statistics in the simple fashion. The procedure is applied on different stride interval data sets from human gait measurements time series (Physio-Bank data library). Results show that introduced mapping adequately separates long-memory from random behavior. Smaller gait data sets were analyzed and scale-free trends for limited scale intervals were successfully detected. The method was verified on artificially produced time series with known scaling behavior and with the varying content of noise. The possibility for the method to falsely detect long-range dependence in the artificially generated short range dependence series was investigated. (c) 2009 Elsevier B.V. All rights reserved.
[Effect of near infrared spectrum on the precision of PLS model for oil yield from oil shale].
Wang, Zhi-Hong; Liu, Jie; Chen, Xiao-Chao; Sun, Yu-Yang; Yu, Yang; Lin, Jun
2012-10-01
It is impossible to use present measurement methods for the oil yield of oil shale to realize in-situ detection and these methods unable to meet the requirements of the oil shale resources exploration and exploitation. But in-situ oil yield analysis of oil shale can be achieved by the portable near infrared spectroscopy technique. There are different correlativities of NIR spectrum data formats and contents of sample components, and the different absorption specialities of sample components shows in different NIR spectral regions. So with the proportioning samples, the PLS modeling experiments were done by 3 formats (reflectance, absorbance and K-M function) and 4 regions of modeling spectrum, and the effect of NIR spectral format and region to the precision of PLS model for oil yield from oil shale was studied. The results show that the best data format is reflectance and the best modeling region is combination spectral range by PLS model method and proportioning samples. Therefore, the appropriate data format and the proper characteristic spectral region can increase the precision of PLS model for oil yield form oil shale.
NASA Astrophysics Data System (ADS)
Hu, Yaogai; Shen, Aiguo; Jiang, Tao; Ai, Yong; Hu, Jiming
2008-02-01
Thirty-two samples from the human gastric mucosa tissue, including 13 normal and 19 malignant tissue samples were measured by confocal Raman microspectroscopy. The low signal-to-background ratio spectra from human gastric mucosa tissues were obtained by this technique without any sample preparation. Raman spectral interferences include a broad featureless sloping background due to fluorescence and noise. They mask most Raman spectral feature and lead to problems with precision and quantitation of the original spectral information. A preprocessed algorithm based on wavelet analysis was used to reduce noise and eliminate background/baseline of Raman spectra. Comparing preprocessed spectra of malignant gastric mucosa tissues with those of counterpart normal ones, there were obvious spectral changes, including intensity increase at ˜1156 cm -1 and intensity decrease at ˜1587 cm -1. The quantitative criterion based upon the intensity ratio of the ˜1156 and ˜1587 cm -1 was extracted for classification of the normal and malignant gastric mucosa tissue samples. This could result in a new diagnostic method, which would assist the early diagnosis of gastric cancer.
Otterman, Joseph; Fraser, R. S.; Bahethi, O. P.
1982-01-01
Characteristics of tropospheric desert aerosols are derived by comparing nadir spectral reflectivities computed from the radiative transfer models with reflectivities measured from Landsat. Over the ocean, reflectivities are compared, but over land the comparison is carried out by determining the ratios of the nadir reflectivity of the surface-atmosphere system over heavy aerosol concentration to the reflectivity of the underlying surface. This remote sensing technique is found to be a sensitive approach for measuring n2, the imaginary part of the refractive index. The desert aerosols under study, in the Iran and Pakistan area, are essentially pure scatterers, inasmuch as an n2 value of 0.001±0.001 was determined for each of the four Landsat spectral bands, that is, for a spectral interval from 0.5 to 1.1 μm.
NASA Astrophysics Data System (ADS)
Han, Kai; Xu, Xiaojun; Liu, Zejin
2013-05-01
Based on the spectral manipulation technique, the Stimulated Brillouin Scattering (SBS) suppression effect and the coherent beam combination (CBC) effect in multi-tone CBC system are researched theoretically and experimentally. To get satisfactory SBS suppression, the frequency interval of the multi-tone seed laser should be large enough, at least larger than the SBS gain bandwidth. In order to attain excellent CBC effect, the spectra of the multi-tone seed laser need to be matched with the optical path differences among the amplifier chains. Hence, a sufficiently separated matching spectrum is capable at both SBS mitigation and coherent property preservation. By comparing the SBS suppression effect and the CBC effect at various spectra, the optimal spectral structure for simultaneous SBS suppression and excellent CBC effect is found.
Noninvasive diagnosis of oral cancer by Stokes shift spectroscopy
NASA Astrophysics Data System (ADS)
Ebenezar, Jeyasingh; Ganesan, Singaravelu; Aruna, Prakasrao; Muralinaidu, Radhakrishnan
2014-03-01
The objective of this study is to evaluate the diagnostic potential of stokes shift (SS) spectroscopy (S3) for normal, precancer and cancerous oral lesions in vivo. The SS spectra were recorded in the 250 - 650 nm spectral range by simultaneously scanning both the excitation and emission wavelengths while keeping a fixed wavelength interval Δλ=20 nm between them. Characteristic, highly resolved peaks and significant spectral differences between normal and different pathological oral lesions observed around 300, 355, 395, and 420 nm which are attributed to tryptophan, collagen, and NADH respectively. Using S3 technique one can obtain the key fluorophores in a single scan and hence they can be targeted as a tumor markers in this study. In order to quantify the altered spectral differences between normal and different pathological oral lesions are verified by different ratio parameters.
Interactive spectral analyzer and comparator (ISAAC)
NASA Astrophysics Data System (ADS)
Latković, O.; Cséki, A.; Vince, I.
2003-10-01
We are developing an application for graphical comparison of observed and synthetic spectra (ISAAC). Synthetic spectrum calculation is performed by SPECTRUM, Stellar Spectral Synthesis Program by Richard O. Gray that we use with his kind permission. This program computes line profiles under LTE conditions in the given wavelength interval using a stellar (solar) atmosphere model, a spectral line data list (wavelength, energy levels, oscillator strengths, and damping constants), a file containing data for atoms and molecules, as well as a data file for hydrogen line profiles calculation. ISAAC offers a simple interface for viewing and changing any atomic parameter SPECTRUM uses for line profile calculation, enabling quick comparison of the new synthetic line profile with the observed one. In this way parameters like relative abundances, oscillator strengths and van der Waals damping constants can be improved, achieving a better agreement with the observed spectrum.
Castiglioni, Paolo; Di Rienzo, Marco; Radaelli, Alberto
2013-11-01
Fractal analysis is a promising tool for assessing autonomic influences on heart rate (HR) and blood pressure (BP) variability. The temporal spectrum of scale coefficients, α(t), was recently proposed to describe the cardiovascular fractal dynamics. Aim of our work is to evaluate sympathetic influences on cardiovascular variability analyzing α(t) and spectral powers of HR and BP after ganglionic blockade. BP was recorded in 11 rats before and after autonomic blockade by hexamethonium infusion (HEX). Systolic and diastolic BP, pulse pressure and pulse interval were derived beat-by-beat. Segments longer than 5 min were selected at baseline and HEX to estimate power spectra and α(t). Comparisons were made by paired t-test. HEX reduced all spectral components of systolic and diastolic BP, the reduction being particularly significant around the frequency of Mayer waves; it induced a reduction on α(t) coefficients at t<2s and an increase on coefficients at t>8s. HEX reduced only slower components of pulse interval power spectrum, but decreased significantly faster scale coefficients (t<8s). HEX only marginally affected pulse pressure variability. Results indicate that the sympathetic outflow contributes to BP fractal dynamics with fractional Gaussian noise (α<1) at longer scales and fractional Brownian motion (α>1) at shorter scales. Ganglionic blockade also removes a fractional Brownian motion component at shorter scales from HR dynamics. Results may be explained by the characteristic time constants between sympathetic efferent activity and cardiovascular effectors. Therefore fractal analysis may complete spectral analysis with information on the correlation structure of the data. Copyright © 2013 Elsevier B.V. All rights reserved.
Darré, Pascaline; Szemendera, Ludovic; Grossard, Ludovic; Delage, Laurent; Reynaud, François
2015-10-05
In the frame of sum frequency generation of a broadband infrared source, we aim to enlarge the converted bandwidth by using a pump frequency comb while keeping a high conversion efficiency. The nonlinear effects are simultaneously induced in the same nonlinear medium. In this paper, we investigate the spectral filtering effect on the temporal coherence behavior with a Mach-Zehnder interferometer using two pump lines. We show that joined effects of quasi-phase matching and spectral sampling lead to an original coherence behavior.
Simultaneous sampling technique for two spectral sources
NASA Technical Reports Server (NTRS)
Jarrett, Olin, Jr.
1987-01-01
A technique is described that uses a bundle of fiber optics to simultaneously sample a dye laser and a spectral lamp. By the use of a real-time display with this technique, the two signals can be superimposed, and the effect of any spectral adjustments can be immediately accessed. In the NASA's CARS system used for combustion diagnostics, the dye laser mixes with a simultaneously pulsed Nd:YAG laser at 532 nm to probe the vibrational levels of nitrogen. An illustration of the oscilloscopic display of the system is presented.
Systolic Processor Array For Recognition Of Spectra
NASA Technical Reports Server (NTRS)
Chow, Edward T.; Peterson, John C.
1995-01-01
Spectral signatures of materials detected and identified quickly. Spectral Analysis Systolic Processor Array (SPA2) relatively inexpensive and satisfies need to analyze large, complex volume of multispectral data generated by imaging spectrometers to extract desired information: computational performance needed to do this in real time exceeds that of current supercomputers. Locates highly similar segments or contiguous subsegments in two different spectra at time. Compares sampled spectra from instruments with data base of spectral signatures of known materials. Computes and reports scores that express degrees of similarity between sampled and data-base spectra.
The U. S. Geological Survey, Digital Spectral Library: Version 1 (0.2 to 3.0um)
Clark, Roger N.; Swayze, Gregg A.; Gallagher, Andrea J.; King, Trude V.V.; Calvin, Wendy M.
1993-01-01
We have developed a digital reflectance spectral library, with management and spectral analysis software. The library includes 498 spectra of 444 samples (some samples include a series of grain sizes) measured from approximately 0.2 to 3.0 um . The spectral resolution (Full Width Half Maximum) of the reflectance data is <= 4 nm in the visible (0.2-0.8 um) and <= 10 nm in the NIR (0.8-2.35 um). All spectra were corrected to absolute reflectance using an NIST Halon standard. Library management software lets users search on parameters (e.g. chemical formulae, chemical analyses, purity of samples, mineral groups, etc.) as well as spectral features. Minerals from borate, carbonate, chloride, element, halide, hydroxide, nitrate, oxide, phosphate, sulfate, sulfide, sulfosalt, and the silicate (cyclosilicate, inosilicate, nesosilicate, phyllosilicate, sorosilicate, and tectosilicate) classes are represented. X-Ray and chemical analyses are tabulated for many of the entries, and all samples have been evaluated for spectral purity. The library also contains end and intermediate members for the olivine, garnet, scapolite, montmorillonite, muscovite, jarosite, and alunite solid-solution series. We have included representative spectra of H2O ice, kerogen, ammonium-bearing minerals, rare-earth oxides, desert varnish coatings, kaolinite crystallinity series, kaolinite-smectite series, zeolite series, and an extensive evaporite series. Because of the importance of vegetation to climate-change studies we have include 17 spectra of tree leaves, bushes, and grasses. The library and software are available as a series of U.S.G.S. Open File reports. PC user software is available to convert the binary data to ascii files (a separate U.S.G.S. open file report). Additionally, a binary data files are on line at the U.S.G.S. in Denver for anonymous ftp to users on the Internet. The library search software enables a user to search on documentation parameters as well as spectral features. The analysis system includes general spectral analysis routines, plotting packages, radiative transfer software for computing intimate mixtures, routines to derive optical constants from reflectance spectra, tools to analyze spectral features, and the capability to access imaging spectrometer data cubes for spectral analysis. Users may build customized libraries (at specific wavelengths and spectral resolution) for their own instruments using the library software. We are currently extending spectral coverage to 150 um. The libraries (original and convolved) will be made available in the future on a CD-ROM.
NASA Astrophysics Data System (ADS)
Spencer, S.; Ogle, S.; Borch, T.; Rock, B.
2008-12-01
Monitoring soil C stocks is critical to assess the impact of future climate and land use change on carbon sinks and sources in agricultural lands. A benchmark network for soil carbon monitoring of stock changes is being designed for US agricultural lands with 3000-5000 sites anticipated and re-sampling on a 5- to10-year basis. Approximately 1000 sites would be sampled per year producing around 15,000 soil samples to be processed for total, organic, and inorganic carbon, as well as bulk density and nitrogen. Laboratory processing of soil samples is cost and time intensive, therefore we are testing the efficacy of using near-infrared (NIR) and mid-infrared (MIR) spectral methods for estimating soil carbon. As part of an initial implementation of national soil carbon monitoring, we collected over 1800 soil samples from 45 cropland sites in the mid-continental region of the U.S. Samples were processed using standard laboratory methods to determine the variables above. Carbon and nitrogen were determined by dry combustion and inorganic carbon was estimated with an acid-pressure test. 600 samples are being scanned using a bench- top NIR reflectance spectrometer (30 g of 2 mm oven-dried soil and 30 g of 8 mm air-dried soil) and 500 samples using a MIR Fourier-Transform Infrared Spectrometer (FTIR) with a DRIFT reflectance accessory (0.2 g oven-dried ground soil). Lab-measured carbon will be compared to spectrally-estimated carbon contents using Partial Least Squares (PLS) multivariate statistical approach. PLS attempts to develop a soil C predictive model that can then be used to estimate C in soil samples not lab-processed. The spectral analysis of soil samples either whole or partially processed can potentially save both funding resources and time to process samples. This is particularly relevant for the implementation of a national monitoring network for soil carbon. This poster will discuss our methods, initial results and potential for using NIR and MIR spectral approaches to either replace or augment traditional lab-based carbon analyses of soils.
NASA Astrophysics Data System (ADS)
Andrews, S. K.; Driver, S. P.; Davies, L. J. M.; Kafle, P. R.; Robotham, A. S. G.; Vinsen, K.; Wright, A. H.; Bland-Hawthorn, J.; Bourne, N.; Bremer, M.; da Cunha, E.; Drinkwater, M.; Holwerda, B.; Hopkins, A. M.; Kelvin, L. S.; Loveday, J.; Phillipps, S.; Wilkins, S.
2017-09-01
We present the evolution of the cosmic spectral energy distribution (CSED) from z = 1 to 0. Our CSEDs originate from stacking individual spectral energy distribution (SED) fits based on panchromatic photometry from the Galaxy And Mass Assembly (GAMA) and COSMOS data sets in 10 redshift intervals with completeness corrections applied. Below z = 0.45, we have credible SED fits from 100 nm to 1 mm. Due to the relatively low sensitivity of the far-infrared data, our far-infrared CSEDs contain a mix of predicted and measured fluxes above z = 0.45. Our results include appropriate errors to highlight the impact of these corrections. We show that the bolometric energy output of the Universe has declined by a factor of roughly 4 - from 5.1 ± 1.0 at z ˜ 1 to 1.3 ± 0.3 × 1035 h70 W Mpc-3 at the current epoch. We show that this decrease is robust to cosmic sample variance, the SED modelling and other various types of error. Our CSEDs are also consistent with an increase in the mean age of stellar populations. We also show that dust attenuation has decreased over the same period, with the photon escape fraction at 150 nm increasing from 16 ± 3 at z ˜ 1 to 24 ± 5 per cent at the current epoch, equivalent to a decrease in AFUV of 0.4 mag. Our CSEDs account for 68 ± 12 and 61 ± 13 per cent of the cosmic optical and infrared backgrounds, respectively, as defined from integrated galaxy counts and are consistent with previous estimates of the cosmic infrared background with redshift.
Preliminary Results Of PCA On MRO CRISM Multispectral Images
NASA Astrophysics Data System (ADS)
Klassen, David R.; Smith, M. D.
2008-09-01
Mars Reconnaissance Orbiter arrived at Mars in March 2006 and by September had achieved its science-phase orbit with the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) beginning its visible to near-infrared (VIS/NIR) spectral imaging shortly thereafter. One of the goals of CRISM is to fill in the spatial gaps between the various targeted observations, eventually mapping the entire surface. Due to the large volume of data this would create, the instrument works in a reduced spectral sampling mode creating "multispectral” images. From this data we can create image cubes using 70 wavelengths from 0.410 to 3.504 µm. We present here a preliminary analysis of these multispectral mode data products using the technique of Principal Components Analysis. Previous work with ground-based images has shown that over an entire visible hemisphere, there are only three to four meaningful components out of 32-105 wavelengths over 1.5-4.1 µm. The first two of these components are fairly consistent over all time intervals from day-to-day and season-to-season. [1-4] The preliminary work on the CRISM images cubes implies similar results_three to four significant principal components that are fairly consistent over time. We will show these components and a rough linear mixture modeling based on in-data spectral endmembers derived from the extrema of the principal components [5]. References: [1] Klassen, D. R. and Bell III, J. F. (2001) BAAS 33, 1069. [2] Klassen, D. R. and Bell III, J. F. (2003) BAAS, 35, 936. [3] Klassen, D. R., Wark, T. J., Cugliotta, C. G. (2005) BAAS, 37, 693. [4] Klassen, D. R. and Bell III, J. F. (2007) in preparation. [5] Klassen, D. R. and Bell III, J. F. (2000) BAAS, 32, 1105.
The high throughput virtual slit enables compact, inexpensive Raman spectral imagers
NASA Astrophysics Data System (ADS)
Gooding, Edward; Deutsch, Erik R.; Huehnerhoff, Joseph; Hajian, Arsen R.
2018-02-01
Raman spectral imaging is increasingly becoming the tool of choice for field-based applications such as threat, narcotics and hazmat detection; air, soil and water quality monitoring; and material ID. Conventional fiber-coupled point source Raman spectrometers effectively interrogate a small sample area and identify bulk samples via spectral library matching. However, these devices are very slow at mapping over macroscopic areas. In addition, the spatial averaging performed by instruments that collect binned spectra, particularly when used in combination with orbital raster scanning, tends to dilute the spectra of trace particles in a mixture. Our design, employing free space line illumination combined with area imaging, reveals both the spectral and spatial content of heterogeneous mixtures. This approach is well suited to applications such as detecting explosives and narcotics trace particle detection in fingerprints. The patented High Throughput Virtual Slit1 is an innovative optical design that enables compact, inexpensive handheld Raman spectral imagers. HTVS-based instruments achieve significantly higher spectral resolution than can be obtained with conventional designs of the same size. Alternatively, they can be used to build instruments with comparable resolution to large spectrometers, but substantially smaller size, weight and unit cost, all while maintaining high sensitivity. When used in combination with laser line imaging, this design eliminates sample photobleaching and unwanted photochemistry while greatly enhancing mapping speed, all with high selectivity and sensitivity. We will present spectral image data and discuss applications that are made possible by low cost HTVS-enabled instruments.
[Measurement and comparison of the spectral transmittance of cerinate porcelain and human enamel].
Chen, Ji-Hua; Zhou, Guo-Feng; Wei, Zhang-Rui; Wang, Hui; Zhao, San-Jun
2006-12-01
To measure the spectral transmittance of Cerinate porcelain veneer and enamel in different color and different thickness. Samples of Cerinate porcelain veneers were prepared in different thickness (0.50 mm, 0.75 mm, 1.00 mm) and different Vita shade (A1, A2, A3). Enamel samples in shade A2 were made with three thickness (0.50 mm, 0.75 mm, 1.00 mm). A spectrophotometer with spectra range (380-800 nm) was employed to measure the spectral transmittance. Spectral transmittance decreased with the increasing in the thickness of specimens and decreasing in the color darkness. The transmittance of Cerinate porcelain veneer material and enamel in the same color and same thickness hadn't significant difference. The key factor to spectral transmittance of porcelain veneer materials is veneer's thickness, and the color of the materials has also some influence on it. Cerinate porcelain veneers can properly recover the transparency of teeth.
Classical least squares multivariate spectral analysis
Haaland, David M.
2002-01-01
An improved classical least squares multivariate spectral analysis method that adds spectral shapes describing non-calibrated components and system effects (other than baseline corrections) present in the analyzed mixture to the prediction phase of the method. These improvements decrease or eliminate many of the restrictions to the CLS-type methods and greatly extend their capabilities, accuracy, and precision. One new application of PACLS includes the ability to accurately predict unknown sample concentrations when new unmodeled spectral components are present in the unknown samples. Other applications of PACLS include the incorporation of spectrometer drift into the quantitative multivariate model and the maintenance of a calibration on a drifting spectrometer. Finally, the ability of PACLS to transfer a multivariate model between spectrometers is demonstrated.
NASA Astrophysics Data System (ADS)
Zhang, Ji; Li, Bing; Wang, Qi; Li, Chengzhi; Zhang, Yinming; Lin, Hancheng; Wang, Zhenyuan
2017-02-01
Postmortem interval (PMI) determination is one of the most challenging tasks in forensic medicine due to a lack of accurate and reliable methods. It is especially difficult for late PMI determination. Although many attempts with various types of body fluids based on chemical methods have been made to solve this problem, few investigations are focused on blood samples. In this study, we employed an attenuated total reflection (ATR)-Fourier transform infrared (FTIR) technique coupled with principle component analysis (PCA) to monitor biochemical changes in rabbit plasma with increasing PMI. Partial least square (PLS) model was used based on the spectral data for PMI prediction in an independent sample set. Our results revealed that postmortem chemical changes in compositions of the plasma were time-dependent, and various components including proteins, lipids and nucleic acids contributed to the discrimination of the samples at different time points. A satisfactory prediction within 48 h postmortem was performed by the combined PLS model with a good fitting between actual and predicted PMI of 0.984 and with an error of ± 1.92 h. In consideration of the simplicity and portability of ATR-FTIR, our preliminary study provides an experimental and theoretical basis for application of this technique in forensic practice.
Dual-wavelength dual-cavity spectrometer for NO2 detection in the presence of aerosol interference
NASA Astrophysics Data System (ADS)
Chandran, Satheesh; Puthukkudy, Anin; Varma, Ravi
2017-07-01
Precise determination of concentration of gases, such as NO2, in urban atmosphere is crucial in studying chemical reactions leading to secondary pollutants. In this study, a novel and sensitive yet simple and cost effective spectrometer was developed where two laser wavelengths and two parallel identical optical cavities were used. Monitoring of NO2 even in the presence of aerosol spectral interference was demonstrated. The intensity transmitted through one cavity, evacuated to 0.1 mbar, was designated as the reference signal ( I 0) while that through the other cavity, sampling air at atmospheric pressure, was designated as sample signal ( I). Quasi-simultaneous measurements of these I 0 and I were done for both laser wavelengths sequentially: one at 406.4 nm near the peak of the largest electronic transition of NO2 and the other at 446.9 nm, away from the peak yet exhibiting significant absorption. The addition of the second wavelength where NO2 has absorption was to ascertain the presence of aerosol scattering and compensate for it. Aerosol extinctions at both operating wavelengths were assumed to be the same, their ratio taken as unity for simplicity, and aerosol light extinction was retrieved. The spectrometer with average sampling interval of 5 s exhibited detection sensitivity of low parts per billion concentrations.
Lan, Gongpu; Li, Guoqiang
2017-01-01
Nonlinear sampling of the interferograms in wavenumber (k) space degrades the depth-dependent signal sensitivity in conventional spectral domain optical coherence tomography (SD-OCT). Here we report a linear-in-wavenumber (k-space) spectrometer for an ultra-broad bandwidth (760 nm–920 nm) SD-OCT, whereby a combination of a grating and a prism serves as the dispersion group. Quantitative ray tracing is applied to optimize the linearity and minimize the optical path differences for the dispersed wavenumbers. Zemax simulation is used to fit the point spread functions to the rectangular shape of the pixels of the line-scan camera and to improve the pixel sampling rates. An experimental SD-OCT is built to test and compare the performance of the k-space spectrometer with that of a conventional one. Design results demonstrate that this k-space spectrometer can reduce the nonlinearity error in k-space from 14.86% to 0.47% (by approximately 30 times) compared to the conventional spectrometer. The 95% confidence interval for RMS diameters is 5.48 ± 1.76 μm—significantly smaller than both the pixel size (14 μm × 28 μm) and the Airy disc (25.82 μm in diameter, calculated at the wavenumber of 7.548 μm−1). Test results demonstrate that the fall-off curve from the k-space spectrometer exhibits much less decay (maximum as −5.20 dB) than the conventional spectrometer (maximum as –16.84 dB) over the whole imaging depth (2.2 mm). PMID:28266502
Alterations in Neural Control of Constant Isometric Contraction with the Size of Error Feedback
Hwang, Ing-Shiou; Lin, Yen-Ting; Huang, Wei-Min; Yang, Zong-Ru; Hu, Chia-Ling; Chen, Yi-Ching
2017-01-01
Discharge patterns from a population of motor units (MUs) were estimated with multi-channel surface electromyogram and signal processing techniques to investigate parametric differences in low-frequency force fluctuations, MU discharges, and force-discharge relation during static force-tracking with varying sizes of execution error presented via visual feedback. Fourteen healthy adults produced isometric force at 10% of maximal voluntary contraction through index abduction under three visual conditions that scaled execution errors with different amplification factors. Error-augmentation feedback that used a high amplification factor (HAF) to potentiate visualized error size resulted in higher sample entropy, mean frequency, ratio of high-frequency components, and spectral dispersion of force fluctuations than those of error-reducing feedback using a low amplification factor (LAF). In the HAF condition, MUs with relatively high recruitment thresholds in the dorsal interosseous muscle exhibited a larger coefficient of variation for inter-spike intervals and a greater spectral peak of the pooled MU coherence at 13–35 Hz than did those in the LAF condition. Manipulation of the size of error feedback altered the force-discharge relation, which was characterized with non-linear approaches such as mutual information and cross sample entropy. The association of force fluctuations and global discharge trace decreased with increasing error amplification factor. Our findings provide direct neurophysiological evidence that favors motor training using error-augmentation feedback. Amplification of the visualized error size of visual feedback could enrich force gradation strategies during static force-tracking, pertaining to selective increases in the discharge variability of higher-threshold MUs that receive greater common oscillatory inputs in the β-band. PMID:28125658
A Spectral Library of Emissivity Spectra for MERTIS on BepiColombo
NASA Astrophysics Data System (ADS)
Maturilli, A.; Helbert, J.; Varatharajan, I.; D'Amore, M.; Hiesinger, H.
2018-05-01
At PSL we measured emissivity spectra in vacuum for a suite of Mercury surface analogues for temperatures from 100°C to >400°C. The spectral library is completed by reflectance on samples fresh and post-heating (0.2 to 200 µm spectral range).
Improved confidence intervals when the sample is counted an integer times longer than the blank.
Potter, William Edward; Strzelczyk, Jadwiga Jodi
2011-05-01
Past computer solutions for confidence intervals in paired counting are extended to the case where the ratio of the sample count time to the blank count time is taken to be an integer, IRR. Previously, confidence intervals have been named Neyman-Pearson confidence intervals; more correctly they should have been named Neyman confidence intervals or simply confidence intervals. The technique utilized mimics a technique used by Pearson and Hartley to tabulate confidence intervals for the expected value of the discrete Poisson and Binomial distributions. The blank count and the contribution of the sample to the gross count are assumed to be Poisson distributed. The expected value of the blank count, in the sample count time, is assumed known. The net count, OC, is taken to be the gross count minus the product of IRR with the blank count. The probability density function (PDF) for the net count can be determined in a straightforward manner.
On the Relationship Between Hyperspectral Data and Foliar Nitrogen Content in Closed Canopy Forests
NASA Astrophysics Data System (ADS)
Knyazikhin, Y.; Schull, M.; Lepine, L. C.; Stenberg, P.; Mõttus, M.; Rautiainen, M.; Latorre, P.; Myneni, R.; Kaufmann, R.
2011-12-01
The importance of nitrogen for terrestrial ecosystem carbon dynamics and its climate feedback has been well recognized by the ecological community. Interaction between carbon and nitrogen at leaf level is among the fundamental mechanisms that directly control the dynamics of terrestrial vegetation carbon. This process influences absorption and scattering of solar radiation by foliage, which in turn impacts radiation reflected by the vegetation and measured by satellite sensors. NASA's Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) and ground based data on canopy structure and foliage nitrogen concentration acquired over six sites in Maine, New England, Florida, North Carolina and Washington were analyzed to assess the role of canopy structure, leaf optics and its biochemical constituents in the spectral variation of radiation reflected by the forest. The study sites represent closed canopy forests (LAI~5). Our results suggest: 1. Impact of canopy structure is so strong that it can significantly suppress the sensitivity of hyperspectral data to leaf optics. 2. Forest reflectance spectra in the interval [710, 790 nm] are required to obtain the fraction of the total leaf area that a "sensor sees" in a given direction. For closed canopy forests its retrieval does not require canopy reflectance models, suggesting that canopy reflectance spectra in this interval provide a direct estimate of the leaf area fraction. 3. The leaf area fraction fully explains variation in measured reflectance spectra due to variation in canopy structure. This variable is used to estimate the mean leaf scattering over foliage that the "sensor sees." For example the nadir-viewing AVIRIS sensor accumulates foliage optical properties over 25% of the total foliage area in needle leaf forest and about 50% in broadleaf forest. 4. Leaf surface properties have an impact on forest reflectivity, lowering its sensitivity to leaf absorbing pigments. 5. Variation in foliar nitrogen concentration can explain up to 55% of variation in AVIRIS spectra in the interval between 400 and 900 nm. The remaining factors could be due to (a) impact of leaf surface properties and/or (b) under-sampling of leaf optical properties due to the single view of the AVIRIS sensor. The theory of canopy spectral invariants underlies the separation of leaf scattering from the total canopy reflectance spectrum.
NASA Astrophysics Data System (ADS)
Zou, Wen-bo; Chong, Xiao-meng; Wang, Yan; Hu, Chang-qin
2018-05-01
The accuracy of NIR quantitative models depends on calibration samples with concentration variability. Conventional sample collecting methods have some shortcomings especially the time-consuming which remains a bottleneck in the application of NIR models for Process Analytical Technology (PAT) control. A study was performed to solve the problem of sample selection collection for construction of NIR quantitative models. Amoxicillin and potassium clavulanate oral dosage forms were used as examples. The aim was to find a normal approach to rapidly construct NIR quantitative models using an NIR spectral library based on the idea of a universal model [2021]. The NIR spectral library of amoxicillin and potassium clavulanate oral dosage forms was defined and consisted of spectra of 377 batches of samples produced by 26 domestic pharmaceutical companies, including tablets, dispersible tablets, chewable tablets, oral suspensions, and granules. The correlation coefficient (rT) was used to indicate the similarities of the spectra. The samples’ calibration sets were selected from a spectral library according to the median rT of the samples to be analyzed. The rT of the samples selected was close to the median rT. The difference in rT of those samples was 1.0% to 1.5%. We concluded that sample selection is not a problem when constructing NIR quantitative models using a spectral library versus conventional methods of determining universal models. The sample spectra with a suitable concentration range in the NIR models were collected quickly. In addition, the models constructed through this method were more easily targeted.
Infrared Absorption by Atmospheric Aerosols in Mexico City during MILAGRO.
NASA Astrophysics Data System (ADS)
Kelley, K. L.; Mangu, A.; Gaffney, J. S.; Marley, N. A.
2007-12-01
Past research in our group using cylindrical internal reflectance spectroscopy has indicated that aqueous aerosols could contribute to the radiative warming as greenhouse species (1,2). Although aerosol radiative effects have been known for sometime and are considered one of the major uncertainties in climate change modeling, most of the studies have focused on the forcing due to scattering and absorption of radiation in the uv- visible region (3). Infrared spectral information also allows the confirmation of key functional groups that are responsible for enhanced absorption observations from secondary organics in the uv-visible region. This work extends our efforts to evaluate the infrared absorption by aerosols, particularly organics, that are now found to be a major fraction of urban and regional aerosols in the 0.1 to 1.0 micron size range and to help identify key types of organics that can contribute to aerosol absorption. During the MILAGRO campaign, quartz filter samples were taken at 12-hour intervals from 5 am to 5 pm (day) and from 5 pm to 5 am (night) during the month of March 2006. These samples were taken at the two super-sites, T-0 (Instituto Mexicano de Petroleo in Mexico City) and T-1 (Universidad Technologica de Tecamac, State of Mexico). The samples have been characterized for total carbon content (stable isotope mass spectroscopy) and natural radionuclide tracers, as well as for their UV-visible spectroscopic properties by using integrating sphere diffuse reflectance spectroscopy (Beckman DU with a Labsphere accessory). These same samples have been characterized in the mid and near infrared spectral ranges using diffuse reflection spectroscopy (Nicolet 6700 FTIR with a Smart Collector accessory). Aerosol samples were removed from the surfaces of the aerosol filters by using Si-Carb sampler. The samples clearly indicate the presence of carbonyl organic constituents and the spectra are quite similar to those observed for humic and fulvic acids found as colloidal materials in surface and groundwaters (4). Examples of the IR spectra obtained and variance as a function of time at the two sites will be presented. The spectra are taken in Kubelka - Munk format, which also allows the infrared absorption strengths to be evaluated as function of wavelength. The wavelength dependence of the aerosol complex refractive index (m = n + ik) in the infrared spectral region is determined by application of the Kramers Kronig function. The importance of the aerosol absorption in the infrared spectral region to radiative forcing will be discussed. 1. N.A. Marley, J.S. Gaffney, and M.M. Cunningham,Environ. Sci. Technol. 27 2864-2869 (1993). 2. N.A. Marley, J.S. Gaffney, and M.M. Cunningham, Spectroscopy 7 44-53 (1992). 3. J.S. Gaffney and N.A. Marley, Atmospheric Environment, New Directions contribution, 32, 2873-2874 (1998). 4. N.A. Marley, J.S. Gaffney, and K.A. Orlandini, Chapter 7 in Humic/Fulvic Acids and Organic Colloidal Materials in the Environment, ACS Symposium Series 651, American Chemical Society, Washington, D.C., pp. 96-107, 1996. This work was performed as part of the Department of Energy's Megacity Aerosol Experiment - Mexico City (MAX- Mex) under the support of the Atmospheric Science Program. This research was supported by the Office of Science (BER), U.S. Department of Energy, Grant No. DE-FG02-07ER64328.
Comparing interval estimates for small sample ordinal CFA models
Natesan, Prathiba
2015-01-01
Robust maximum likelihood (RML) and asymptotically generalized least squares (AGLS) methods have been recommended for fitting ordinal structural equation models. Studies show that some of these methods underestimate standard errors. However, these studies have not investigated the coverage and bias of interval estimates. An estimate with a reasonable standard error could still be severely biased. This can only be known by systematically investigating the interval estimates. The present study compares Bayesian, RML, and AGLS interval estimates of factor correlations in ordinal confirmatory factor analysis models (CFA) for small sample data. Six sample sizes, 3 factor correlations, and 2 factor score distributions (multivariate normal and multivariate mildly skewed) were studied. Two Bayesian prior specifications, informative and relatively less informative were studied. Undercoverage of confidence intervals and underestimation of standard errors was common in non-Bayesian methods. Underestimated standard errors may lead to inflated Type-I error rates. Non-Bayesian intervals were more positive biased than negatively biased, that is, most intervals that did not contain the true value were greater than the true value. Some non-Bayesian methods had non-converging and inadmissible solutions for small samples and non-normal data. Bayesian empirical standard error estimates for informative and relatively less informative priors were closer to the average standard errors of the estimates. The coverage of Bayesian credibility intervals was closer to what was expected with overcoverage in a few cases. Although some Bayesian credibility intervals were wider, they reflected the nature of statistical uncertainty that comes with the data (e.g., small sample). Bayesian point estimates were also more accurate than non-Bayesian estimates. The results illustrate the importance of analyzing coverage and bias of interval estimates, and how ignoring interval estimates can be misleading. Therefore, editors and policymakers should continue to emphasize the inclusion of interval estimates in research. PMID:26579002
Comparing interval estimates for small sample ordinal CFA models.
Natesan, Prathiba
2015-01-01
Robust maximum likelihood (RML) and asymptotically generalized least squares (AGLS) methods have been recommended for fitting ordinal structural equation models. Studies show that some of these methods underestimate standard errors. However, these studies have not investigated the coverage and bias of interval estimates. An estimate with a reasonable standard error could still be severely biased. This can only be known by systematically investigating the interval estimates. The present study compares Bayesian, RML, and AGLS interval estimates of factor correlations in ordinal confirmatory factor analysis models (CFA) for small sample data. Six sample sizes, 3 factor correlations, and 2 factor score distributions (multivariate normal and multivariate mildly skewed) were studied. Two Bayesian prior specifications, informative and relatively less informative were studied. Undercoverage of confidence intervals and underestimation of standard errors was common in non-Bayesian methods. Underestimated standard errors may lead to inflated Type-I error rates. Non-Bayesian intervals were more positive biased than negatively biased, that is, most intervals that did not contain the true value were greater than the true value. Some non-Bayesian methods had non-converging and inadmissible solutions for small samples and non-normal data. Bayesian empirical standard error estimates for informative and relatively less informative priors were closer to the average standard errors of the estimates. The coverage of Bayesian credibility intervals was closer to what was expected with overcoverage in a few cases. Although some Bayesian credibility intervals were wider, they reflected the nature of statistical uncertainty that comes with the data (e.g., small sample). Bayesian point estimates were also more accurate than non-Bayesian estimates. The results illustrate the importance of analyzing coverage and bias of interval estimates, and how ignoring interval estimates can be misleading. Therefore, editors and policymakers should continue to emphasize the inclusion of interval estimates in research.
Spectral interpolation - Zero fill or convolution. [image processing
NASA Technical Reports Server (NTRS)
Forman, M. L.
1977-01-01
Zero fill, or augmentation by zeros, is a method used in conjunction with fast Fourier transforms to obtain spectral spacing at intervals closer than obtainable from the original input data set. In the present paper, an interpolation technique (interpolation by repetitive convolution) is proposed which yields values accurate enough for plotting purposes and which lie within the limits of calibration accuracies. The technique is shown to operate faster than zero fill, since fewer operations are required. The major advantages of interpolation by repetitive convolution are that efficient use of memory is possible (thus avoiding the difficulties encountered in decimation in time FFTs) and that is is easy to implement.
Pollack, J B; Veverka, J; Pang, K; Colburn, D; Lane, A L; Ajello, J M
1978-01-06
The reflectivity of Phobos has been determined in the spectral region from 0.4 to 1.1 micrometers from images taken with a Viking lander camera. The reflectivity curve is flat in this spectral interval and the geometric albedo equals 0.05 +/- 0.01. These results, together with Phobos's reflectivity spectrum in the ultraviolet, are compared with laboratory spectra of carbonaceous chondrites and basalts. The spectra of carbonaceous chondrites are consistent with the observations, whereas the basalt spectra are not. These findings raise the possibility that Phobos may be a captured object rather than a natural satellite of Mars.
Multistage Spectral Relaxation Method for Solving the Hyperchaotic Complex Systems
Saberi Nik, Hassan; Rebelo, Paulo
2014-01-01
We present a pseudospectral method application for solving the hyperchaotic complex systems. The proposed method, called the multistage spectral relaxation method (MSRM) is based on a technique of extending Gauss-Seidel type relaxation ideas to systems of nonlinear differential equations and using the Chebyshev pseudospectral methods to solve the resulting system on a sequence of multiple intervals. In this new application, the MSRM is used to solve famous hyperchaotic complex systems such as hyperchaotic complex Lorenz system and the complex permanent magnet synchronous motor. We compare this approach to the Runge-Kutta based ode45 solver to show that the MSRM gives accurate results. PMID:25386624
Least Squares Moving-Window Spectral Analysis.
Lee, Young Jong
2017-08-01
Least squares regression is proposed as a moving-windows method for analysis of a series of spectra acquired as a function of external perturbation. The least squares moving-window (LSMW) method can be considered an extended form of the Savitzky-Golay differentiation for nonuniform perturbation spacing. LSMW is characterized in terms of moving-window size, perturbation spacing type, and intensity noise. Simulation results from LSMW are compared with results from other numerical differentiation methods, such as single-interval differentiation, autocorrelation moving-window, and perturbation correlation moving-window methods. It is demonstrated that this simple LSMW method can be useful for quantitative analysis of nonuniformly spaced spectral data with high frequency noise.
John, Emily E; Nekouei, Omid; McClure, J T; Cameron, Marguerite; Keefe, Greg; Stryhn, Henrik
2018-06-01
Bulk tank milk (BTM) samples are used to determine the infection status and estimate dairy herd prevalence for bovine leukaemia virus (BLV) using an antibody ELISA assay. BLV ELISA variability between samples from the same herd or from different herds has not been investigated over long time periods. The main objective of this study was to determine the within-herd and between-herd variability of a BTM BLV ELISA assay over 1-month, 3-month, and 3-year sampling intervals. All of the Canadian Maritime region dairy herds (n = 523) that were active in 2013 and 2016 were included (83.9% and 86.9% of total herds in 2013 and 2016, respectively). BLV antibody levels were measured in three BTM samples collected at 1-month intervals in early 2013 as well as two BTM samples collected over a 3-month interval in early 2016. Random-effects models, with fixed effects for sample replicate and province and random effects for herd, were used to estimate the variability between BTM samples from the same herd and between herds for 1-month, 3-month, and 3-year sampling intervals. The majority of variability of BTM BLV ELISA results was seen between herds (1-month, 6.792 ± 0.533; 3-month, 7.806 ± 0.652; 3-year, 6.222 ± 0.528). Unexplained variance between samples from the same herd, on square-root scale, was greatest for the 3-year (0.976 ± 0.104), followed by the 1-month (0.611 ± 0.035) then the 3-month (0.557 ± 0.071) intervals. Variability of BTM antibody levels within the same herd was present but was much smaller than the variability between herds, and was greatest for the 3-year sampling interval. The 3-month sampling interval resulted in the least variability and is appropriate to use for estimating the baseline level of within-herd prevalence for BLV control programs. Knowledge of the baseline variability and within-herd prevalence can help to determine effectiveness of control programs when BTM sampling is repeated at longer intervals. Copyright © 2018 Elsevier B.V. All rights reserved.
Development of a System Model for Non-Invasive Quantification of Bilirubin in Jaundice Patients
NASA Astrophysics Data System (ADS)
Alla, Suresh K.
Neonatal jaundice is a medical condition which occurs in newborns as a result of an imbalance between the production and elimination of bilirubin. Excess bilirubin in the blood stream diffuses into the surrounding tissue leading to a yellowing of the skin. An optical system integrated with a signal processing system is used as a platform to noninvasively quantify bilirubin concentration through the measurement of diffuse skin reflectance. Initial studies have lead to the generation of a clinical analytical model for neonatal jaundice which generates spectral reflectance data for jaundiced skin with varying levels of bilirubin concentration in the tissue. The spectral database built using the clinical analytical model is then used as a test database to validate the signal processing system in real time. This evaluation forms the basis for understanding the translation of this research to human trials. The clinical analytical model and signal processing system have been successful validated on three spectral databases. First spectral database is constructed using a porcine model as a surrogate for neonatal skin tissue. Samples of pig skin were soaked in bilirubin solutions of varying concentrations to simulate jaundice skin conditions. The resulting skins samples were analyzed with our skin reflectance systems producing bilirubin concentration values that show a high correlation (R2 = 0.94) to concentration of the bilirubin solution that each porcine tissue sample is soaked in. The second spectral database is the spectral measurements collected on human volunteers to quantify the different chromophores and other physical properties of the tissue such a Hematocrit, Hemoglobin etc. The third spectral database is the spectral data collected at different time periods from the moment a bruise is induced.
Spectral feature characterization methods for blood stain detection in crime scene backgrounds
NASA Astrophysics Data System (ADS)
Yang, Jie; Mathew, Jobin J.; Dube, Roger R.; Messinger, David W.
2016-05-01
Blood stains are one of the most important types of evidence for forensic investigation. They contain valuable DNA information, and the pattern of the stains can suggest specifics about the nature of the violence that transpired at the scene. Blood spectral signatures containing unique reflectance or absorption features are important both for forensic on-site investigation and laboratory testing. They can be used for target detection and identification applied to crime scene hyperspectral imagery, and also be utilized to analyze the spectral variation of blood on various backgrounds. Non-blood stains often mislead the detection and can generate false alarms at a real crime scene, especially for dark and red backgrounds. This paper measured the reflectance of liquid blood and 9 kinds of non-blood samples in the range of 350 nm - 2500 nm in various crime scene backgrounds, such as pure samples contained in petri dish with various thicknesses, mixed samples with different colors and materials of fabrics, and mixed samples with wood, all of which are examined to provide sub-visual evidence for detecting and recognizing blood from non-blood samples in a realistic crime scene. The spectral difference between blood and non-blood samples are examined and spectral features such as "peaks" and "depths" of reflectance are selected. Two blood stain detection methods are proposed in this paper. The first method uses index to denote the ratio of "depth" minus "peak" over"depth" add"peak" within a wavelength range of the reflectance spectrum. The second method uses relative band depth of the selected wavelength ranges of the reflectance spectrum. Results show that the index method is able to discriminate blood from non-blood samples in most tested crime scene backgrounds, but is not able to detect it from black felt. Whereas the relative band depth method is able to discriminate blood from non-blood samples on all of the tested background material types and colors.
Liu, Ya-Fei; Yuan, Hong-Fu; Song, Chun-Feng; Xie, Jin-Chun; Li, Xiao-Yu; Yan, De-Lin
2014-11-01
A new method is proposed for the fast determination of the induction period of gasoline using Fourier transform attenuated total reflection infrared spectroscopy (ATR-FTIR). A dedicated analysis system with the function of spectral measurement, data processing, display and storage was designed and integrated using a Fourier transform infrared spectrometer module and chemometric software. The sample presentation accessory designed which has advantages of constant optical path, convenient sample injection and cleaning is composed of a nine times reflection attenuated total reflectance (ATR) crystal of zinc selenide (ZnSe) coated with a diamond film and a stainless steel lid with sealing device. The influence of spectral scanning number and repeated sample loading times on the spectral signal-to-noise ratio was studied. The optimum spectral scanning number is 15 times and the optimum sample loading number is 4 times. Sixty four different gasoline samples were collected from the Beijing-Tianjin area and the induction period values were determined as reference data by standard method GB/T 8018-87. The infrared spectra of these samples were collected in the operating condition mentioned above using the dedicated fast analysis system. Spectra were pretreated using mean centering and 1st derivative to reduce the influence of spectral noise and baseline shift A PLS calibration model for the induction period was established by correlating the known induction period values of the samples with their spectra. The correlation coefficient (R2), standard error of calibration (SEC) and standard error of prediction (SEP) of the model are 0.897, 68.3 and 91.9 minutes, respectively. The relative deviation of the model for gasoline induction period prediction is less than 5%, which meets the requirements of repeatability tolerance in GB method. The new method is simple and fast. It takes no more than 3 minutes to detect one sample. Therefore, the method is feasible for implementing fast determination of gasoline induction period, and of a positive meaning in the evaluation of fuel quality.
Trofimov, Vyacheslav A.; Varentsova, Svetlana A.
2017-01-01
We have studied the spectral resolution influence on the accuracy of the substance detection and identification at using a broadband THz pulse measured under real conditions (at a distance of more than 3 m from a THz emitter in ambient air with a relative humidity of about 50%). We show that increasing spectral resolution leads to manifestation of small-scale perturbations (random fluctuations) in the signal spectrum caused by the influence of the environment or the sample structure. Decreasing the spectral resolution allows us to exclude from consideration this small-scale modulation of the signal as well as to detect the water vapor absorption frequencies. This fact is important in practice because it allows us to increase the signal processing rate. In order to increase the detection reliability, it is advisable to decrease the spectral resolution up to values of not more than 40% of the corresponding spectral line bandwidth. The method of spectral dynamics analysis together with the integral correlation criteria is used for the substance detection and identification. Neutral substances such as chocolate and cookies are used as the samples in the physical experiment. PMID:29231895
Spectral Analysis; Applications in Water Pollution Control.
ERIC Educational Resources Information Center
Wastler, T. A.
The statistical technique of analyzing data collected at regular intervals to reveal periodic components of the data is described by reference to actual records. The data chosen for illustration include tide height in a river; biochemical oxygen demand and dissolved oxygen in the same river; discharged salt into a river system and its relation to…
Effect of Age on Silent Gap Discrimination in Synthetic Speech Stimuli.
ERIC Educational Resources Information Center
Lister, Jennifer; Tarver, Kenton
2004-01-01
The difficulty that older listeners experience understanding conversational speech may be related to their limited ability to use information present in the silent intervals (i.e., temporal gaps) between dynamic speech sounds. When temporal gaps are present between nonspeech stimuli that are spectrally invariant (e.g., noise bands or sinusoids),…
[Influence of geomagnetic storms on the balance of autonomic regulatory mechanisms].
Chichinadze, G; Tvildiani, L; Kvachadze, I; Tarkhan-Mouravi, I
2005-09-01
The investigation aimed to evaluate autonomic regulatory mechanisms in practically healthy persons during the geomagnetically quiet periods and during geomagnetic storms. The examinations were conducted among the volunteer young men (n=64) 18-22 years of age. The autonomic function was studied on the basis of the heart rate variability. The geomagnetically quiet periods were considered when the value of the K-index was no more then 2 and a geomagnetic storm was considered when the value of the index was 5 and more. It is ascertained that in the both cases the basic statistical indices of the heart rate were identical. The analysis of R-R intervals spectral power gave the possibility to sort the persons examined into the three different groups. The data obtained allowed to suggest that geomagnetic storms influence human organisms through the vagus centers by means of their excitation. This phenomenon may be considered as a self-regulatory physiologic mechanism of the adaptive character. The analysis of the spectral power of R-R intervals may be considered as a sensitive method for the detection of the magnitolabile persons.
High temperature spectral emissivity measurement using integral blackbody method
NASA Astrophysics Data System (ADS)
Pan, Yijie; Dong, Wei; Lin, Hong; Yuan, Zundong; Bloembergen, Pieter
2016-10-01
Spectral emissivity is a critical material's thermos-physical property for heat design and radiation thermometry. A prototype instrument based upon an integral blackbody method was developed to measure material's spectral emissivity above 1000 °. The system was implemented with an optimized commercial variable-high-temperature blackbody, a high speed linear actuator, a linear pyrometer, and an in-house designed synchronization circuit. A sample was placed in a crucible at the bottom of the blackbody furnace, by which the sample and the tube formed a simulated blackbody which had an effective total emissivity greater than 0.985. During the measurement, the sample was pushed to the end opening of the tube by a graphite rod which was actuated through a pneumatic cylinder. A linear pyrometer was used to monitor the brightness temperature of the sample surface through the measurement. The corresponding opto-converted voltage signal was fed and recorded by a digital multi-meter. A physical model was proposed to numerically evaluate the temperature drop along the process. Tube was discretized as several isothermal cylindrical rings, and the temperature profile of the tube was measurement. View factors between sample and rings were calculated and updated along the whole pushing process. The actual surface temperature of the sample at the end opening was obtained. Taking advantages of the above measured voltage profile and the calculated true temperature, spectral emissivity under this temperature point was calculated.
Effects of sampling interval on spatial patterns and statistics of watershed nitrogen concentration
Wu, S.-S.D.; Usery, E.L.; Finn, M.P.; Bosch, D.D.
2009-01-01
This study investigates how spatial patterns and statistics of a 30 m resolution, model-simulated, watershed nitrogen concentration surface change with sampling intervals from 30 m to 600 m for every 30 m increase for the Little River Watershed (Georgia, USA). The results indicate that the mean, standard deviation, and variogram sills do not have consistent trends with increasing sampling intervals, whereas the variogram ranges remain constant. A sampling interval smaller than or equal to 90 m is necessary to build a representative variogram. The interpolation accuracy, clustering level, and total hot spot areas show decreasing trends approximating a logarithmic function. The trends correspond to the nitrogen variogram and start to level at a sampling interval of 360 m, which is therefore regarded as a critical spatial scale of the Little River Watershed. Copyright ?? 2009 by Bellwether Publishing, Ltd. All right reserved.
NASA Astrophysics Data System (ADS)
Martinez, Mathieu; Bodin, Stéphane; Krencker, François-Nicolas
2015-04-01
The Pliensbachian and Toarcian stages (Early Jurassic) are marked by a series of carbon cycle disturbances, major climatic changes and severe faunal turnovers. An accurate knowledge of the timing of the Pliensbachian-Toarcian age is a key for quantifying fluxes and rhythms of faunal and geochemical processes during these major environmental perturbations. Although many studies provided astrochronological frameworks of the Toarcian Stage and the Toarcian oceanic anoxic event, no precise time frame exists for the Pliensbachian-Toarcian transition, often condensed in the previously studied sections. Here, we provide an astrochronology of the Pliensbachian-Toarcian transition in the Foum Tillicht section (central High Atlas, Morocco). The section is composed of decimetric hemipelagic marl-limestone alternations accompanied by cyclic fluctuations in the δ13Cmicrite. In this section, the marl-limestone alternations reflect cyclic sea-level/climatic changes, which triggers rhythmic migrations of the surrounding carbonate platforms and modulates the amount of carbonate exported to the basin. The studied interval encompasses 142.15 m of the section, from the base of the series to a hiatus in the Early Toarcian, marked by an erosional surface. The Pliensbachian-Toarcian (P-To) Event, a negative excursion in carbonate δ13Cmicrite, is observed pro parte in this studied interval. δ13Cmicrite measurements were performed every ~2 m at the base of the section and every 0.20 m within the P-To Event interval. Spectral analyses were performed using the multi-taper method and the evolutive Fast Fourier Transform to get the accurate assessment of the main significant periods and their evolution throughout the studied interval. Two main cycles are observed in the series: the 405-kyr eccentricity cycles is observed throughout the series, while the obliquity cycles is observed within the P-To Event, in the most densely sampled interval. The studied interval covers a 3.6-Myr interval. The duration of the part of P-To Event covered in this analysis is assessed at 0.70 Myr. In addition, the interval from the base of the Toarcian to the first occurrence of the calcareous nannofossil C. superbus has a duration assessed from 0.47 to 0.55 Myr. This duration is significantly higher than most of assessments obtained by former cyclostratigraphy analyses, showing that previous studies underestimated the duration of this interval, often condensed in the Western Tethys. This study shows the potential of the Foum Tillicht section to provide a refined time frame of the Pliensbachian-Toarcian boundary, which could be integrated in the next Geological Time Scale.
Ntakatsane, M P; Yang, X Q; Lin, M; Liu, X M; Zhou, P
2011-11-01
Thirteen milk brands comprising 76 pasteurized and UHT milk samples of various compositions (whole, reduced fat, skimmed, low lactose, and high protein) were obtained from local supermarkets, and milk samples manufactured in various countries were discriminated using front-face fluorescence spectroscopy (FFFS) coupled with chemometric tools. The emission spectra of Maillard reaction products and riboflavin (MRP/RF; 400 to 600 nm) and tryptophan (300 to 400 nm) were recorded using FFFS, and the excitation wavelengths were set at 360 nm for MRP/RF and 290 nm for tryptophan. Principal component analysis (PCA) was applied to analyze the normalized spectra. The PCA of spectral information from MRP/RF discriminated the milk samples originating in different countries, and PCA of spectral information from tryptophan discriminated the samples according to composition. The fluorescence spectral data were compared with liquid chromatography-mass spectrometry results for the glycation extent of the milk samples, and a positive association (R(2)=0.84) was found between the degree of glycation of α-lactalbumin and the MRP/RF spectral data. This study demonstrates the ability and sensitivity of FFFS to rapidly discriminate and classify commercial milk with various compositions and processing conditions. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Effect of acoustic similarity on short-term auditory memory in the monkey.
Scott, Brian H; Mishkin, Mortimer; Yin, Pingbo
2013-04-01
Recent evidence suggests that the monkey's short-term memory in audition depends on a passively retained sensory trace as opposed to a trace reactivated from long-term memory for use in working memory. Reliance on a passive sensory trace could render memory particularly susceptible to confusion between sounds that are similar in some acoustic dimension. If so, then in delayed matching-to-sample, the monkey's performance should be predicted by the similarity in the salient acoustic dimension between the sample and subsequent test stimulus, even at very short delays. To test this prediction and isolate the acoustic features relevant to short-term memory, we examined the pattern of errors made by two rhesus monkeys performing a serial, auditory delayed match-to-sample task with interstimulus intervals of 1 s. The analysis revealed that false-alarm errors did indeed result from similarity-based confusion between the sample and the subsequent nonmatch stimuli. Manipulation of the stimuli showed that removal of spectral cues was more disruptive to matching behavior than removal of temporal cues. In addition, the effect of acoustic similarity on false-alarm response was stronger at the first nonmatch stimulus than at the second one. This pattern of errors would be expected if the first nonmatch stimulus overwrote the sample's trace, and suggests that the passively retained trace is not only vulnerable to similarity-based confusion but is also highly susceptible to overwriting. Copyright © 2013 Elsevier B.V. All rights reserved.
Introduction to Sample Size Choice for Confidence Intervals Based on "t" Statistics
ERIC Educational Resources Information Center
Liu, Xiaofeng Steven; Loudermilk, Brandon; Simpson, Thomas
2014-01-01
Sample size can be chosen to achieve a specified width in a confidence interval. The probability of obtaining a narrow width given that the confidence interval includes the population parameter is defined as the power of the confidence interval, a concept unfamiliar to many practitioners. This article shows how to utilize the Statistical Analysis…
Combined optical coherence tomography and hyper-spectral imaging using a double clad fiber coupler
NASA Astrophysics Data System (ADS)
Guay-Lord, Robin; Lurie, Kristen L.; Attendu, Xavier; Mageau, Lucas; Godbout, Nicolas; Ellerbee Bowden, Audrey K.; Strupler, Mathias; Boudoux, Caroline
2016-03-01
This proceedings shows the combination of Optical Coherence Tomography (OCT) and Hyper-Spectral Imaging (HSI) using a double-clad optical fiber. The single mode core of the fiber is used to transmit OCT signals, while the cladding, with its large collection area, provides an efficient way to capture the reflectance spectrum of the sample. The combination of both methods enables three-dimensional acquisition of sample morphology with OCT, enhanced by the molecular information contained in its hyper-spectral image. We believe that the combination of these techniques could result in endoscopes with enhanced tissue identification capability.
Multi-spectral endogenous fluorescence imaging for bacterial differentiation
NASA Astrophysics Data System (ADS)
Chernomyrdin, Nikita V.; Babayants, Margarita V.; Korotkov, Oleg V.; Kudrin, Konstantin G.; Rimskaya, Elena N.; Shikunova, Irina A.; Kurlov, Vladimir N.; Cherkasova, Olga P.; Komandin, Gennady A.; Reshetov, Igor V.; Zaytsev, Kirill I.
2017-07-01
In this paper, the multi-spectral endogenous fluorescence imaging was implemented for bacterial differentiation. The fluorescence imaging was performed using a digital camera equipped with a set of visual bandpass filters. Narrowband 365 nm ultraviolet radiation passed through a beam homogenizer was used to excite the sample fluorescence. In order to increase a signal-to-noise ratio and suppress a non-fluorescence background in images, the intensity of the UV excitation was modulated using a mechanical chopper. The principal components were introduced for differentiating the samples of bacteria based on the multi-spectral endogenous fluorescence images.
Nessen, Merel A; van der Zwaan, Dennis J; Grevers, Sander; Dalebout, Hans; Staats, Martijn; Kok, Esther; Palmblad, Magnus
2016-05-11
Proteomics methodology has seen increased application in food authentication, including tandem mass spectrometry of targeted species-specific peptides in raw, processed, or mixed food products. We have previously described an alternative principle that uses untargeted data acquisition and spectral library matching, essentially spectral counting, to compare and identify samples without the need for genomic sequence information in food species populations. Here, we present an interlaboratory comparison demonstrating how a method based on this principle performs in a realistic context. We also increasingly challenge the method by using data from different types of mass spectrometers, by trying to distinguish closely related and commercially important flatfish, and by analyzing heavily contaminated samples. The method was found to be robust in different laboratories, and 94-97% of the analyzed samples were correctly identified, including all processed and contaminated samples.
Ryder, Alan G
2002-03-01
Eighty-five solid samples consisting of illegal narcotics diluted with several different materials were analyzed by near-infrared (785 nm excitation) Raman spectroscopy. Principal Component Analysis (PCA) was employed to classify the samples according to narcotic type. The best sample discrimination was obtained by using the first derivative of the Raman spectra. Furthermore, restricting the spectral variables for PCA to 2 or 3% of the original spectral data according to the most intense peaks in the Raman spectrum of the pure narcotic resulted in a rapid discrimination method for classifying samples according to narcotic type. This method allows for the easy discrimination between cocaine, heroin, and MDMA mixtures even when the Raman spectra are complex or very similar. This approach of restricting the spectral variables also decreases the computational time by a factor of 30 (compared to the complete spectrum), making the methodology attractive for rapid automatic classification and identification of suspect materials.
Spectral Characterization of Analog Samples in Anticipation of OSIRIS-REx's Arrival at Bennu
NASA Technical Reports Server (NTRS)
Donaldson Hanna, K. L.; Schrader, D. L.; Bowles, N. E.; Clark, B. E.; Cloutis, E. A.; Connolly, H. C., Jr.; Hamilton, V. E.; Keller, L. P.; Lauretta, D. S.; Lim, L. F.;
2017-01-01
NASA's Origins, Spectral Interpretation, Resource Identification, and Security-Regolith Explorer (OSIRIS-REx) mission successfully launched on September 8th, 2016. During its rendezvous with near-Earth asteroid (101955) Bennu beginning in 2018, OSIRIS-REx will characterize the asteroid's physical, mineralogical, and chemical properties in an effort to globally map the properties of Bennu, a primitive carbonaceous asteroid, and choose a sampling location [e.g. 1]. In preparation for these observations, we spectrally characterized a suite of analog samples across visible, near- and thermal-infrared wavelengths and used these in initial tests of phase detection and abundance determination software algorithms. Here we present the thermal infrared laboratory measurements of the analog sample suite measured under asteroidlike conditions, which are relevant to the interpretation of spectroscopic observations by the OSIRIS-REx Thermal Emission Spectrometer (OTES) [2, 3]. This suite of laboratory measurements of asteroid analogs under asteroid-like conditions is the first of their kind.
NASA Technical Reports Server (NTRS)
Kapahi, Vijay K.; Kulkarni, Vasant K.
1990-01-01
VLA observations of a complete subset of the Leiden-Berkeley Deep Survey sources that have S(1.4 GHz) greater than 10 mJy and are not optically identified down to F=22 mag are reported. By comparing the spectral and structural properties of the sources with samples from the literature, an attempt was made to disentangle the luminosity and redshift dependence of the spectral indices of extended emission in radio galaxies and of the incidence of compact steep-spectrum sources. It is found that the fraction of compact sources among those with a steep spectrum is related primarily to redshift, being much larger at high redshifts for sources of similar radio luminosity. Only a weak and marginally significant dependence of spectral indices of the extended sources on luminosity and redshift is found in samples selected at 1.4 and 2.7 GHz. It is pointed out that the much stronger correlation of spectral indices with luminosity may be arising partly from spectral curvature, and partly due to the preferential inclusion of very steep-spectrum sources from high redshift in low-frequency surveys.
NASA Astrophysics Data System (ADS)
Yan, Wen-juan; Yang, Ming; He, Guo-quan; Qin, Lin; Li, Gang
2014-11-01
In order to identify the diabetic patients by using tongue near-infrared (NIR) spectrum - a spectral classification model of the NIR reflectivity of the tongue tip is proposed, based on the partial least square (PLS) method. 39sample data of tongue tip's NIR spectra are harvested from healthy people and diabetic patients , respectively. After pretreatment of the reflectivity, the spectral data are set as the independent variable matrix, and information of classification as the dependent variables matrix, Samples were divided into two groups - i.e. 53 samples as calibration set and 25 as prediction set - then the PLS is used to build the classification model The constructed modelfrom the 53 samples has the correlation of 0.9614 and the root mean square error of cross-validation (RMSECV) of 0.1387.The predictions for the 25 samples have the correlation of 0.9146 and the RMSECV of 0.2122.The experimental result shows that the PLS method can achieve good classification on features of healthy people and diabetic patients.
Garcia, Jair E.; Girard, Madeline B.; Kasumovic, Michael; Petersen, Phred; Wilksch, Philip A.; Dyer, Adrian G.
2015-01-01
Background The ability to discriminate between two similar or progressively dissimilar colours is important for many animals as it allows for accurately interpreting visual signals produced by key target stimuli or distractor information. Spectrophotometry objectively measures the spectral characteristics of these signals, but is often limited to point samples that could underestimate spectral variability within a single sample. Algorithms for RGB images and digital imaging devices with many more than three channels, hyperspectral cameras, have been recently developed to produce image spectrophotometers to recover reflectance spectra at individual pixel locations. We compare a linearised RGB and a hyperspectral camera in terms of their individual capacities to discriminate between colour targets of varying perceptual similarity for a human observer. Main Findings (1) The colour discrimination power of the RGB device is dependent on colour similarity between the samples whilst the hyperspectral device enables the reconstruction of a unique spectrum for each sampled pixel location independently from their chromatic appearance. (2) Uncertainty associated with spectral reconstruction from RGB responses results from the joint effect of metamerism and spectral variability within a single sample. Conclusion (1) RGB devices give a valuable insight into the limitations of colour discrimination with a low number of photoreceptors, as the principles involved in the interpretation of photoreceptor signals in trichromatic animals also apply to RGB camera responses. (2) The hyperspectral camera architecture provides means to explore other important aspects of colour vision like the perception of certain types of camouflage and colour constancy where multiple, narrow-band sensors increase resolution. PMID:25965264
Minimum and Maximum Times Required to Obtain Representative Suspended Sediment Samples
NASA Astrophysics Data System (ADS)
Gitto, A.; Venditti, J. G.; Kostaschuk, R.; Church, M. A.
2014-12-01
Bottle sampling is a convenient method of obtaining suspended sediment measurements for the development of sediment budgets. While these methods are generally considered to be reliable, recent analysis of depth-integrated sampling has identified considerable uncertainty in measurements of grain-size concentration between grain-size classes of multiple samples. Point-integrated bottle sampling is assumed to represent the mean concentration of suspended sediment but the uncertainty surrounding this method is not well understood. Here we examine at-a-point variability in velocity, suspended sediment concentration, grain-size distribution, and grain-size moments to determine if traditional point-integrated methods provide a representative sample of suspended sediment. We present continuous hour-long observations of suspended sediment from the sand-bedded portion of the Fraser River at Mission, British Columbia, Canada, using a LISST laser-diffraction instrument. Spectral analysis suggests that there are no statistically significant peak in energy density, suggesting the absence of periodic fluctuations in flow and suspended sediment. However, a slope break in the spectra at 0.003 Hz corresponds to a period of 5.5 minutes. This coincides with the threshold between large-scale turbulent eddies that scale with channel width/mean velocity and hydraulic phenomena related to channel dynamics. This suggests that suspended sediment samples taken over a period longer than 5.5 minutes incorporate variability that is larger scale than turbulent phenomena in this channel. Examination of 5.5-minute periods of our time series indicate that ~20% of the time a stable mean value of volumetric concentration is reached within 30 seconds, a typical bottle sample duration. In ~12% of measurements a stable mean was not reached over the 5.5 minute sample duration. The remaining measurements achieve a stable mean in an even distribution over the intervening interval.
Absolute sensitivity calibration of an extreme ultraviolet spectrometer for tokamak measurements
NASA Astrophysics Data System (ADS)
Guirlet, R.; Schwob, J. L.; Meyer, O.; Vartanian, S.
2017-01-01
An extreme ultraviolet spectrometer installed on the Tore Supra tokamak has been calibrated in absolute units of brightness in the range 10-340 Å. This has been performed by means of a combination of techniques. The range 10-113 Å was absolutely calibrated by using an ultrasoft-X ray source emitting six spectral lines in this range. The calibration transfer to the range 113-182 Å was performed using the spectral line intensity branching ratio method. The range 182-340 Å was calibrated thanks to radiative-collisional modelling of spectral line intensity ratios. The maximum sensitivity of the spectrometer was found to lie around 100 Å. Around this wavelength, the sensitivity is fairly flat in a 80 Å wide interval. The spatial variations of sensitivity along the detector assembly were also measured. The observed trend is related to the quantum efficiency decrease as the angle of the incoming photon trajectories becomes more grazing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anthonisen, Madeleine; Brandenberger, Robert; Laguë, Alex
Cosmic string loops contain cusps which decay by emitting bursts of particles. A significant fraction of the released energy is in the form of photons. These photons are injected non-thermally and can hence cause spectral distortions of the Cosmic Microwave Background (CMB). Under the assumption that cusps are robust against gravitational back-reaction, we compute the fractional energy density released as photons in the redshift interval where such non-thermal photon injection causes CMB spectral distortions. Whereas current constraints on such spectral distortions are not strong enough to constrain the string tension, future missions such as the PIXIE experiment will be ablemore » to provide limits which rule out a range of string tensions between G μ ∼ 10{sup −15} and G μ ∼ 10{sup −12}, thus ruling out particle physics models yielding these kind of intermediate-scale cosmic strings.« less
Confidence Intervals for Proportion Estimates in Complex Samples. Research Report. ETS RR-06-21
ERIC Educational Resources Information Center
Oranje, Andreas
2006-01-01
Confidence intervals are an important tool to indicate uncertainty of estimates and to give an idea of probable values of an estimate if a different sample from the population was drawn or a different sample of measures was used. Standard symmetric confidence intervals for proportion estimates based on a normal approximation can yield bounds…
Statistical properties of Fermi GBM GRBs' spectra
NASA Astrophysics Data System (ADS)
Rácz, István I.; Balázs, Lajos G.; Horvath, Istvan; Tóth, L. Viktor; Bagoly, Zsolt
2018-03-01
Statistical studies of gamma-ray burst (GRB) spectra may result in important information on the physics of GRBs. The Fermi GBM catalogue contains GRB parameters (peak energy, spectral indices, and intensity) estimated fitting the gamma-ray spectral energy distribution of the total emission (fluence, flnc), and during the time of the peak flux (pflx). Using contingency tables, we studied the relationship of the models best-fitting pflx and flnc time intervals. Our analysis revealed an ordering of the spectra into a power law - Comptonized - smoothly broken power law - Band series. This result was further supported by a correspondence analysis of the pflx and flnc spectra categorical variables. We performed a linear discriminant analysis (LDA) to find a relationship between categorical (spectral) and model independent physical data. LDA resulted in highly significant physical differences among the spectral types, that is more pronounced in the case of the pflx spectra, than for the flnc spectra. We interpreted this difference as caused by the temporal variation of the spectrum during the outburst. This spectral variability is confirmed by the differences in the low-energy spectral index and peak energy, between the pflx and flnc spectra. We found that the synchrotron radiation is significant in GBM spectra. The mean low-energy spectral index is close to the canonical value of α = -2/3 during the peak flux. However, α is ˜ -0.9 for the spectra of the fluences. We interpret this difference as showing that the effect of cooling is important only for the fluence spectra.
Statistical analysis and machine learning algorithms for optical biopsy
NASA Astrophysics Data System (ADS)
Wu, Binlin; Liu, Cheng-hui; Boydston-White, Susie; Beckman, Hugh; Sriramoju, Vidyasagar; Sordillo, Laura; Zhang, Chunyuan; Zhang, Lin; Shi, Lingyan; Smith, Jason; Bailin, Jacob; Alfano, Robert R.
2018-02-01
Analyzing spectral or imaging data collected with various optical biopsy methods is often times difficult due to the complexity of the biological basis. Robust methods that can utilize the spectral or imaging data and detect the characteristic spectral or spatial signatures for different types of tissue is challenging but highly desired. In this study, we used various machine learning algorithms to analyze a spectral dataset acquired from human skin normal and cancerous tissue samples using resonance Raman spectroscopy with 532nm excitation. The algorithms including principal component analysis, nonnegative matrix factorization, and autoencoder artificial neural network are used to reduce dimension of the dataset and detect features. A support vector machine with a linear kernel is used to classify the normal tissue and cancerous tissue samples. The efficacies of the methods are compared.
Development of remote sensing techniques capable of delineating soils as an aid to soil survey
NASA Technical Reports Server (NTRS)
Coleman, T. L.; Montgomery, O. L.
1988-01-01
Eighty-one benchmark soils from Alabama, Georgia, Florida, Tennessee, and Mississippi were evaluated to determine the feasibility of spectrally differentiating among soil categories. Relationships among spectral properties that occur between soils and within soils were examined, using discriminant analysis. Soil spectral data were obtained from air-dried samples using an Exotech Model 20C field spectroradiometer (0.37 to 2.36 microns). Differentiating among the orders, suborders, great groups, and subgroups using reflectance spectra achieved varying percentages of accuracy. Six distinct reflectance curve forms were developed from the air-dried samples based on the shape and presence or absence of adsorption bands. Iron oxide and organic matter content were the dominant soil parameters affecting the spectral characteristics for differentiating among and between these soils.
NASA Astrophysics Data System (ADS)
Shugurov, K. U.; Mozharov, A. M.; Sapunov, G. A.; Fedorov, V. V.; Bolshakov, A. D.; Mukhin, I. S.
2018-03-01
Volt-ampere and spectral characteristics of GaN/Si solar cell samples differing in interface layer preparation are obtained and analyzed. External quantum efficiency curves are experimentally determined via excitation with a 532 nm incident radiation wavelength. It is demonstrated that interface preparation has a significant influence on photovoltaic characteristics of the studied samples.
NASA Astrophysics Data System (ADS)
Hobley, Eleanor; Kriegs, Stefanie; Steffens, Markus
2017-04-01
Obtaining reliable and accurate data regarding the spatial distribution of different soil components is difficult due to issues related with sampling scale and resolution on the one hand and laboratory analysis on the other. When investigating the chemical composition of soil, studies frequently limit themselves to two dimensional characterisations, e.g. spatial variability near the surface or depth distribution down the profile, but rarely combine both approaches due to limitations to sampling and analytical capacities. Furthermore, when assessing depth distributions, samples are taken according to horizon or depth increments, resulting in a mixed sample across the sampling depth. Whilst this facilitates mean content estimation per depth increment and therefore reduces analytical costs, the sample information content with regards to heterogeneity within the profile is lost. Hyperspectral imaging can overcome these sampling limitations, yielding high resolution spectral data of down the soil profile, greatly enhancing the information content of the samples. This can then be used to augment horizontal spatial characterisation of a site, yielding three dimensional information into the distribution of spectral characteristics across a site and down the profile. Soil spectral characteristics are associated with specific chemical components of soil, such as soil organic matter or iron contents. By correlating the content of these soil components with their spectral behaviour, high resolution multi-dimensional analysis of soil chemical composition can be obtained. Here we present a hyperspectral approach to the characterisation of soil organic matter and iron down different soil profiles, outlining advantages and issues associated with the methodology.
NASA Astrophysics Data System (ADS)
Muraviev, A. V.; Smolski, V. O.; Loparo, Z. E.; Vodopyanov, K. L.
2018-04-01
Mid-infrared spectroscopy offers supreme sensitivity for the detection of trace gases, solids and liquids based on tell-tale vibrational bands specific to this spectral region. Here, we present a new platform for mid-infrared dual-comb Fourier-transform spectroscopy based on a pair of ultra-broadband subharmonic optical parametric oscillators pumped by two phase-locked thulium-fibre combs. Our system provides fast (7 ms for a single interferogram), moving-parts-free, simultaneous acquisition of 350,000 spectral data points, spaced by a 115 MHz intermodal interval over the 3.1-5.5 µm spectral range. Parallel detection of 22 trace molecular species in a gas mixture, including isotopologues containing isotopes such as 13C, 18O, 17O, 15N, 34S, 33S and deuterium, with part-per-billion sensitivity and sub-Doppler resolution is demonstrated. The technique also features absolute optical frequency referencing to an atomic clock, a high degree of mutual coherence between the two mid-infrared combs with a relative comb-tooth linewidth of 25 mHz, coherent averaging and feasibility for kilohertz-scale spectral resolution.
A time-spectral approach to numerical weather prediction
NASA Astrophysics Data System (ADS)
Scheffel, Jan; Lindvall, Kristoffer; Yik, Hiu Fai
2018-05-01
Finite difference methods are traditionally used for modelling the time domain in numerical weather prediction (NWP). Time-spectral solution is an attractive alternative for reasons of accuracy and efficiency and because time step limitations associated with causal CFL-like criteria, typical for explicit finite difference methods, are avoided. In this work, the Lorenz 1984 chaotic equations are solved using the time-spectral algorithm GWRM (Generalized Weighted Residual Method). Comparisons of accuracy and efficiency are carried out for both explicit and implicit time-stepping algorithms. It is found that the efficiency of the GWRM compares well with these methods, in particular at high accuracy. For perturbative scenarios, the GWRM was found to be as much as four times faster than the finite difference methods. A primary reason is that the GWRM time intervals typically are two orders of magnitude larger than those of the finite difference methods. The GWRM has the additional advantage to produce analytical solutions in the form of Chebyshev series expansions. The results are encouraging for pursuing further studies, including spatial dependence, of the relevance of time-spectral methods for NWP modelling.
Adjusted Wald Confidence Interval for a Difference of Binomial Proportions Based on Paired Data
ERIC Educational Resources Information Center
Bonett, Douglas G.; Price, Robert M.
2012-01-01
Adjusted Wald intervals for binomial proportions in one-sample and two-sample designs have been shown to perform about as well as the best available methods. The adjusted Wald intervals are easy to compute and have been incorporated into introductory statistics courses. An adjusted Wald interval for paired binomial proportions is proposed here and…
Alfano, Robert R.; Demos, Stavros G.; Zhang, Gang
2003-12-16
Method and an apparatus for examining a tissue using the spectral wing emission therefrom induced by visible to infrared photoexcitation. In one aspect, the method is used to characterize the condition of a tissue sample and comprises the steps of (a) photoexciting the tissue sample with substantially monochromatic light having a wavelength of at least 600 nm; and (b) using the resultant far red and near infrared spectral wing emission (SW) emitted from the tissue sample to characterize the condition of the tissue sample. In one embodiment, the substantially monochromatic photoexciting light is a continuous beam of light, and the resultant steady-state far red and near infrared SW emission from the tissue sample is used to characterize the condition of the tissue sample. In another embodiment, the substantially monochromatic photoexciting light is a light pulse, and the resultant time-resolved far red and near infrared SW emission emitted from the tissue sample is used to characterize the condition of the tissue sample. In still another embodiment, the substantially monochromatic photoexciting light is a polarized light pulse, and the parallel and perpendicular components of the resultant polarized time-resolved SW emission emitted from the tissue sample are used to characterize the condition of the tissue sample.
Controls on Thermal Discharge in Yellowstone NAtional Park, Wyoming
NASA Astrophysics Data System (ADS)
Mohrmann, Jacob Steven
2007-10-01
Significant fluctuations in discharge occur in hot springs in Yellowstone National Park on a seasonal to decadal scale (Ingebritsen et al., 2001) and an hourly scale (Vitale, 2002). The purpose of this study was to determine the interval of the fluctuations in discharge and to explain what causes those discharge patterns in three thermally influenced streams in Yellowstone National Park. By monitoring flow in these streams, whose primary source of input is thermal discharge, we were able to find several significant patterns of discharge fluctuations. Patterns were found by using two techniques of spectral analysis. The spectral analyses completed involved using the program "R" as well as Microsoft Excel, both of which use Fourier transforms. The Fourier transform is a linear operator that identifies frequencies in the original function. Stream flow data were collected using a FloDar open channel flow monitor. The flow meter collected data at15-minute intervals at White Creek and Rabbit Creek for a period of approximately two weeks each during the Fall. Flow data were also used from 15-minute data interval from a USGS gaging station at Tantalus Creek. Patterns of discharge fluctuation were found in each stream. By comparing spectral analysis results of flow data with spectral analysis of published tide data and barometric pressure data, connections were drawn between fluctuations in tidal and barometric-pressure patterns and flow patterns. Also, visual comparisons used to identify potential correspondence with earthquakes and precipitation events. At Tantalus Creek, patterns were affected only by barometric pressure changes. At White Creek, one pattern was attributed to barometric pressure fluctuations, and another pattern was found that could be associated with earth-tide forces. At Rabbit Creek, these patterns were absent. A pattern at 8.55 hours, which could not be attributed to barometric pressure or earth tide forces, was found at Rabbit and White Creeks. The 8.55 hour pattern in discharge found at both Rabbit and White Creeks may suggest a physical link between the sites, which are close (2.5 km). The time pattern could be a result of a shared hydrothermal aquifer, convectively heating and discharging at both streams. However, the common time pattern could also be the result of independent factors, which coincidentally caused a similar time pattern.
Clemens, Béla; Bánk, József; Piros, Pálma; Bessenyei, Mónika; Veto, Sára; Tóth, Márton; Kondákor, István
2008-09-01
Investigating the brain of migraine patients in the pain-free interval may shed light on the basic cerebral abnormality of migraine, in other words, the liability of the brain to generate migraine attacks from time to time. Twenty unmedicated "migraine without aura" patients and a matched group of healthy controls were investigated in this explorative study. 19-channel EEG was recorded against the linked ears reference and was on-line digitized. 60 x 2-s epochs of eyes-closed, waking-relaxed activity were subjected to spectral analysis and a source localization method, low resolution electromagnetic tomography (LORETA). Absolute power was computed for 19 electrodes and four frequency bands (delta: 1.5-3.5 Hz, theta: 4.0-7.5 Hz, alpha: 8.0-12.5 Hz, beta: 13.0-25.0 Hz). LORETA "activity" (=current source density, ampers/meters squared) was computed for 2394 voxels and the above specified frequency bands. Group comparison was carried out for the specified quantitative EEG variables. Activity in the two groups was compared on a voxel-by-voxel basis for each frequency band. Statistically significant (uncorrected P < 0.01) group differences were projected to cortical anatomy. Spectral findings: there was a tendency for more alpha power in the migraine that in the control group in all but two (F4, C3) derivations. However, statistically significant (P < 0.01, Bonferroni-corrected) spectral difference was only found in the right occipital region. The main LORETA-finding was that voxels with P < 0.01 differences were crowded in anatomically contiguous cortical areas. Increased alpha activity was found in a cortical area including part of the precuneus, and the posterior part of the middle temporal gyrus in the right hemisphere. Decreased alpha activity was found bilaterally in medial parts of the frontal cortex including the anterior cingulate and the superior and medial frontal gyri. Neither spectral analysis, nor LORETA revealed statistically significant differences in the delta, theta, and beta bands. LORETA revealed the anatomical distribution of the cortical sources (generators) of the EEG abnormalities in migraine. The findings characterize the state of the cerebral cortex in the pain-free interval and might be suitable for planning forthcoming investigations.
The influence of sampling interval on the accuracy of trail impact assessment
Leung, Y.-F.; Marion, J.L.
1999-01-01
Trail impact assessment and monitoring (IA&M) programs have been growing in importance and application in recreation resource management at protected areas. Census-based and sampling-based approaches have been developed in such programs, with systematic point sampling being the most common survey design. This paper examines the influence of sampling interval on the accuracy of estimates for selected trail impact problems. A complete census of four impact types on 70 trails in Great Smoky Mountains National Park was utilized as the base data set for the analyses. The census data were resampled at increasing intervals to create a series of simulated point data sets. Estimates of frequency of occurrence and lineal extent for the four impact types were compared with the census data set. The responses of accuracy loss on lineal extent estimates to increasing sampling intervals varied across different impact types, while the responses on frequency of occurrence estimates were consistent, approximating an inverse asymptotic curve. These findings suggest that systematic point sampling may be an appropriate method for estimating the lineal extent but not the frequency of trail impacts. Sample intervals of less than 100 m appear to yield an excellent level of accuracy for the four impact types evaluated. Multiple regression analysis results suggest that appropriate sampling intervals are more likely to be determined by the type of impact in question rather than the length of trail. The census-based trail survey and the resampling-simulation method developed in this study can be a valuable first step in establishing long-term trail IA&M programs, in which an optimal sampling interval range with acceptable accuracy is determined before investing efforts in data collection.
Sensitivity analysis of seismic hazard for the northwestern portion of the state of Gujarat, India
Petersen, M.D.; Rastogi, B.K.; Schweig, E.S.; Harmsen, S.C.; Gomberg, J.S.
2004-01-01
We test the sensitivity of seismic hazard to three fault source models for the northwestern portion of Gujarat, India. The models incorporate different characteristic earthquake magnitudes on three faults with individual recurrence intervals of either 800 or 1600 years. These recurrence intervals imply that large earthquakes occur on one of these faults every 266-533 years, similar to the rate of historic large earthquakes in this region during the past two centuries and for earthquakes in intraplate environments like the New Madrid region in the central United States. If one assumes a recurrence interval of 800 years for large earthquakes on each of three local faults, the peak ground accelerations (PGA; horizontal) and 1-Hz spectral acceleration ground motions (5% damping) are greater than 1 g over a broad region for a 2% probability of exceedance in 50 years' hazard level. These probabilistic PGAs at this hazard level are similar to median deterministic ground motions. The PGAs for 10% in 50 years' hazard level are considerably lower, generally ranging between 0.2 g and 0.7 g across northwestern Gujarat. Ground motions calculated from our models that consider fault interevent times of 800 years are considerably higher than other published models even though they imply similar recurrence intervals. These higher ground motions are mainly caused by the application of intraplate attenuation relations, which account for less severe attenuation of seismic waves when compared to the crustal interplate relations used in these previous studies. For sites in Bhuj and Ahmedabad, magnitude (M) 7 3/4 earthquakes contribute most to the PGA and the 0.2- and 1-s spectral acceleration ground motion maps at the two considered hazard levels. ?? 2004 Elsevier B.V. All rights reserved.
Adeli, Khosrow; Higgins, Victoria; Seccombe, David; Collier, Christine P; Balion, Cynthia M; Cembrowski, George; Venner, Allison A; Shaw, Julie
2017-11-01
Reference intervals are widely used decision-making tools in laboratory medicine, serving as health-associated standards to interpret laboratory test results. Numerous studies have shown wide variation in reference intervals, even between laboratories using assays from the same manufacturer. Lack of consistency in either sample measurement or reference intervals across laboratories challenges the expectation of standardized patient care regardless of testing location. Here, we present data from a national survey conducted by the Canadian Society of Clinical Chemists (CSCC) Reference Interval Harmonization (hRI) Working Group that examines variation in laboratory reference sample measurements, as well as pediatric and adult reference intervals currently used in clinical practice across Canada. Data on reference intervals currently used by 37 laboratories were collected through a national survey to examine the variation in reference intervals for seven common laboratory tests. Additionally, 40 clinical laboratories participated in a baseline assessment by measuring six analytes in a reference sample. Of the seven analytes examined, alanine aminotransferase (ALT), alkaline phosphatase (ALP), and creatinine reference intervals were most variable. As expected, reference interval variation was more substantial in the pediatric population and varied between laboratories using the same instrumentation. Reference sample results differed between laboratories, particularly for ALT and free thyroxine (FT4). Reference interval variation was greater than test result variation for the majority of analytes. It is evident that there is a critical lack of harmonization in laboratory reference intervals, particularly for the pediatric population. Furthermore, the observed variation in reference intervals across instruments cannot be explained by the bias between the results obtained on instruments by different manufacturers. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Robust power spectral estimation for EEG data
Melman, Tamar; Victor, Jonathan D.
2016-01-01
Background Typical electroencephalogram (EEG) recordings often contain substantial artifact. These artifacts, often large and intermittent, can interfere with quantification of the EEG via its power spectrum. To reduce the impact of artifact, EEG records are typically cleaned by a preprocessing stage that removes individual segments or components of the recording. However, such preprocessing can introduce bias, discard available signal, and be labor-intensive. With this motivation, we present a method that uses robust statistics to reduce dependence on preprocessing by minimizing the effect of large intermittent outliers on the spectral estimates. New method Using the multitaper method[1] as a starting point, we replaced the final step of the standard power spectrum calculation with a quantile-based estimator, and the Jackknife approach to confidence intervals with a Bayesian approach. The method is implemented in provided MATLAB modules, which extend the widely used Chronux toolbox. Results Using both simulated and human data, we show that in the presence of large intermittent outliers, the robust method produces improved estimates of the power spectrum, and that the Bayesian confidence intervals yield close-to-veridical coverage factors. Comparison to existing method The robust method, as compared to the standard method, is less affected by artifact: inclusion of outliers produces fewer changes in the shape of the power spectrum as well as in the coverage factor. Conclusion In the presence of large intermittent outliers, the robust method can reduce dependence on data preprocessing as compared to standard methods of spectral estimation. PMID:27102041
Robust power spectral estimation for EEG data.
Melman, Tamar; Victor, Jonathan D
2016-08-01
Typical electroencephalogram (EEG) recordings often contain substantial artifact. These artifacts, often large and intermittent, can interfere with quantification of the EEG via its power spectrum. To reduce the impact of artifact, EEG records are typically cleaned by a preprocessing stage that removes individual segments or components of the recording. However, such preprocessing can introduce bias, discard available signal, and be labor-intensive. With this motivation, we present a method that uses robust statistics to reduce dependence on preprocessing by minimizing the effect of large intermittent outliers on the spectral estimates. Using the multitaper method (Thomson, 1982) as a starting point, we replaced the final step of the standard power spectrum calculation with a quantile-based estimator, and the Jackknife approach to confidence intervals with a Bayesian approach. The method is implemented in provided MATLAB modules, which extend the widely used Chronux toolbox. Using both simulated and human data, we show that in the presence of large intermittent outliers, the robust method produces improved estimates of the power spectrum, and that the Bayesian confidence intervals yield close-to-veridical coverage factors. The robust method, as compared to the standard method, is less affected by artifact: inclusion of outliers produces fewer changes in the shape of the power spectrum as well as in the coverage factor. In the presence of large intermittent outliers, the robust method can reduce dependence on data preprocessing as compared to standard methods of spectral estimation. Copyright © 2016 Elsevier B.V. All rights reserved.
Solar Wind Turbulence and Intermittency at 0.72 AU - Statistical Approach
NASA Astrophysics Data System (ADS)
Teodorescu, E.; Echim, M.; Munteanu, C.; Zhang, T.; Barabash, S. V.; Budnik, E.; Fedorov, A.
2014-12-01
Through this analysis we characterize the turbulent magnetic fluctuations by Venus Express Magnetometer, VEX-MAG in the solar wind during the last solar cycle minimum at a distance of 0.72 AU from the Sun. We analyze data recorded between 2007 and 2009 with time resolutions of 1 Hz and 32 Hz. In correlation with plasma data from the ASPERA instrument, Analyser of Space Plasma and Energetic Atoms, we identify 550 time intervals, at 1 Hz resolution, when VEX is in the solar wind and which satisfy selection criteria defined based on the amount and the continuity of the data. We identify 118 time intervals that correspond to fast solar wind. We compute the power spectral densities (PSD) for Bx, By, Bz, B, B2, B|| and B^. We perform a statistical analysis of the spectral indices computed for each of the PSD's and evidence a dependence of the spectral index on the solar wind velocity and a slight difference in power content between parallel and perpendicular components of the magnetic field. We also estimate the scale invariance of fluctuations by computing the Probability Distribution Functions (PDFs) for Bx, By, Bz, B and B2 time series and discuss the implications for intermittent turbulence. Research supported by the European Community's Seventh Framework Programme (FP7/2007-2013) under grant agreement no 313038/STORM, and a grant of the Romanian Ministry of National Education, CNCS - UEFISCDI, project number PN-II-ID-PCE-2012-4-0418.
Spectral signature verification using statistical analysis and text mining
NASA Astrophysics Data System (ADS)
DeCoster, Mallory E.; Firpi, Alexe H.; Jacobs, Samantha K.; Cone, Shelli R.; Tzeng, Nigel H.; Rodriguez, Benjamin M.
2016-05-01
In the spectral science community, numerous spectral signatures are stored in databases representative of many sample materials collected from a variety of spectrometers and spectroscopists. Due to the variety and variability of the spectra that comprise many spectral databases, it is necessary to establish a metric for validating the quality of spectral signatures. This has been an area of great discussion and debate in the spectral science community. This paper discusses a method that independently validates two different aspects of a spectral signature to arrive at a final qualitative assessment; the textual meta-data and numerical spectral data. Results associated with the spectral data stored in the Signature Database1 (SigDB) are proposed. The numerical data comprising a sample material's spectrum is validated based on statistical properties derived from an ideal population set. The quality of the test spectrum is ranked based on a spectral angle mapper (SAM) comparison to the mean spectrum derived from the population set. Additionally, the contextual data of a test spectrum is qualitatively analyzed using lexical analysis text mining. This technique analyzes to understand the syntax of the meta-data to provide local learning patterns and trends within the spectral data, indicative of the test spectrum's quality. Text mining applications have successfully been implemented for security2 (text encryption/decryption), biomedical3 , and marketing4 applications. The text mining lexical analysis algorithm is trained on the meta-data patterns of a subset of high and low quality spectra, in order to have a model to apply to the entire SigDB data set. The statistical and textual methods combine to assess the quality of a test spectrum existing in a database without the need of an expert user. This method has been compared to other validation methods accepted by the spectral science community, and has provided promising results when a baseline spectral signature is present for comparison. The spectral validation method proposed is described from a practical application and analytical perspective.
Average variograms to guide soil sampling
NASA Astrophysics Data System (ADS)
Kerry, R.; Oliver, M. A.
2004-10-01
To manage land in a site-specific way for agriculture requires detailed maps of the variation in the soil properties of interest. To predict accurately for mapping, the interval at which the soil is sampled should relate to the scale of spatial variation. A variogram can be used to guide sampling in two ways. A sampling interval of less than half the range of spatial dependence can be used, or the variogram can be used with the kriging equations to determine an optimal sampling interval to achieve a given tolerable error. A variogram might not be available for the site, but if the variograms of several soil properties were available on a similar parent material and or particular topographic positions an average variogram could be calculated from these. Averages of the variogram ranges and standardized average variograms from four different parent materials in southern England were used to suggest suitable sampling intervals for future surveys in similar pedological settings based on half the variogram range. The standardized average variograms were also used to determine optimal sampling intervals using the kriging equations. Similar sampling intervals were suggested by each method and the maps of predictions based on data at different grid spacings were evaluated for the different parent materials. Variograms of loss on ignition (LOI) taken from the literature for other sites in southern England with similar parent materials had ranges close to the average for a given parent material showing the possible wider application of such averages to guide sampling.
NASA Astrophysics Data System (ADS)
Revercomb, Henry E.; Anderson, James G.; Best, Fred A.; Tobin, David C.; Knuteson, Robert O.; LaPorte, Daniel D.; Taylor, Joe K.
2006-12-01
The new era of high spectral resolution infrared instruments for atmospheric sounding offers great opportunities for climate change applications. A major issue with most of our existing IR observations from space is spectral sampling uncertainty and the lack of standardization in spectral sampling. The new ultra resolution observing capabilities from the AIRS grating spectrometer on the NASA Aqua platform and from new operational FTS instruments (IASI on Metop, CrIS for NPP/NPOESS, and the GIFTS for a GOES demonstration) will go a long way toward improving this situation. These new observations offer the following improvements: 1. Absolute accuracy, moving from issues of order 1 K to <0.2-0.4 K brightness temperature, 2. More complete spectral coverage, with Nyquist sampling for scale standardization, and 3. Capabilities for unifying IR calibration among different instruments and platforms. However, more needs to be done to meet the immediate needs for climate and to effectively leverage these new operational weather systems, including 1. Place special emphasis on making new instruments as accurate as they can be to realize the potential of technological investments already made, 2. Maintain a careful validation program for establishing the best possible direct radiance check of long-term accuracy--specifically, continuing to use aircraft-or balloon-borne instruments that are periodically checked directly with NIST, and 3. Commit to a simple, new IR mission that will provide an ongoing backbone for the climate observing system. The new mission would make use of Fourier Transform Spectrometer measurements to fill in spectral and diurnal sampling gaps of the operational systems and provide a benchmark with better than 0.1K 3-sigma accuracy based on standards that are verifiable in-flight.
Spectral imaging perspective on cytomics.
Levenson, Richard M
2006-07-01
Cytomics involves the analysis of cellular morphology and molecular phenotypes, with reference to tissue architecture and to additional metadata. To this end, a variety of imaging and nonimaging technologies need to be integrated. Spectral imaging is proposed as a tool that can simplify and enrich the extraction of morphological and molecular information. Simple-to-use instrumentation is available that mounts on standard microscopes and can generate spectral image datasets with excellent spatial and spectral resolution; these can be exploited by sophisticated analysis tools. This report focuses on brightfield microscopy-based approaches. Cytological and histological samples were stained using nonspecific standard stains (Giemsa; hematoxylin and eosin (H&E)) or immunohistochemical (IHC) techniques employing three chromogens plus a hematoxylin counterstain. The samples were imaged using the Nuance system, a commercially available, liquid-crystal tunable-filter-based multispectral imaging platform. The resulting data sets were analyzed using spectral unmixing algorithms and/or learn-by-example classification tools. Spectral unmixing of Giemsa-stained guinea-pig blood films readily classified the major blood elements. Machine-learning classifiers were also successful at the same task, as well in distinguishing normal from malignant regions in a colon-cancer example, and in delineating regions of inflammation in an H&E-stained kidney sample. In an example of a multiplexed ICH sample, brown, red, and blue chromogens were isolated into separate images without crosstalk or interference from the (also blue) hematoxylin counterstain. Cytomics requires both accurate architectural segmentation as well as multiplexed molecular imaging to associate molecular phenotypes with relevant cellular and tissue compartments. Multispectral imaging can assist in both these tasks, and conveys new utility to brightfield-based microscopy approaches. Copyright 2006 International Society for Analytical Cytology.
Adenosine deaminase polymorphism affects sleep EEG spectral power in a large epidemiological sample.
Mazzotti, Diego Robles; Guindalini, Camila; de Souza, Altay Alves Lino; Sato, João Ricardo; Santos-Silva, Rogério; Bittencourt, Lia Rita Azeredo; Tufik, Sergio
2012-01-01
Slow wave oscillations in the electroencephalogram (EEG) during sleep may reflect both sleep need and intensity, which are implied in homeostatic regulation. Adenosine is strongly implicated in sleep homeostasis, and a single nucleotide polymorphism in the adenosine deaminase gene (ADA G22A) has been associated with deeper and more efficient sleep. The present study verified the association between the ADA G22A polymorphism and changes in sleep EEG spectral power (from C3-A2, C4-A1, O1-A2, and O2-A1 derivations) in the Epidemiologic Sleep Study (EPISONO) sample from São Paulo, Brazil. Eight-hundred individuals were subjected to full-night polysomnography and ADA G22A genotyping. Spectral analysis of the EEG was carried out in all individuals using fast Fourier transformation of the signals from each EEG electrode. The genotype groups were compared in the whole sample and in a subsample of 120 individuals matched according to ADA genotype for age, gender, body mass index, caffeine intake status, presence of sleep disturbance, and sleep-disturbing medication. When compared with homozygous GG genotype carriers, A allele carriers showed higher delta spectral power in Stage 1 and Stages 3+4 of sleep, and increased theta spectral power in Stages 1, 2 and REM sleep. These changes were seen both in the whole sample and in the matched subset. The higher EEG spectral power indicates that the sleep of individuals carrying the A allele may be more intense. Therefore, this polymorphism may be an important source of variation in sleep homeostasis in humans, through modulation of specific components of the sleep EEG.
Rozenstein, Offer; Puckrin, Eldon; Adamowski, Jan
2017-10-01
Waste sorting is key to the process of waste recycling. Exact identification of plastic resin and wood products using Near Infrared (NIR, 1-1.7µm) sensing is currently in use. Yet, dark targets characterized by low reflectance, such as black plastics, are hard to identify by this method. Following the recent success of Midwave Infrared (MWIR, 3-12µm) measurements to identify coloured plastic polymers, the aim of this study was to assess whether this technique is applicable to sorting black plastic polymers and wood products. We performed infrared reflectance contact measurements of 234 plastic samples and 29 samples of wood and paper products. Plastic samples included black, coloured and transparent Polyethylene Terephthalate (PET), Polyethylene (PE), Polyvinyl Chloride (PVC), Polypropylene (PP), Polylactic acid (PLA) and Polystyrene (PS). The spectral signatures of the black and coloured plastic samples were compared with clear plastic samples and signatures documented in the literature to identify the polymer spectral features in the presence of coloured material. This information was used to determine the spectral bands that best suit the sorting of black plastic polymers. The main NIR-MWIR absorption features of wood, cardboard and paper were identified as well according to the spectral measurements. Good agreement was found between our measurements and the absorption features documented in the literature. The new approach using MWIR spectral features appears to be useful for black plastics as it overcomes some of the limitations in the NIR region to identify them. The main limitation of this technique for industrial applications is the trade-off between the signal-to-noise ratio of the sensor operating in standoff mode and the speed at which waste is moved under the sensor. This limitation can be resolved by reducing the system's spectral resolution to 16cm -1 , which allows for faster spectra acquisition while maintaining a reasonable signal-to-noise ratio. Copyright © 2017 Elsevier Ltd. All rights reserved.
[Development of an analyzing system for soil parameters based on NIR spectroscopy].
Zheng, Li-Hua; Li, Min-Zan; Sun, Hong
2009-10-01
A rapid estimation system for soil parameters based on spectral analysis was developed by using object-oriented (OO) technology. A class of SOIL was designed. The instance of the SOIL class is the object of the soil samples with the particular type, specific physical properties and spectral characteristics. Through extracting the effective information from the modeling spectral data of soil object, a map model was established between the soil parameters and its spectral data, while it was possible to save the mapping model parameters in the database of the model. When forecasting the content of any soil parameter, the corresponding prediction model of this parameter can be selected with the same soil type and the similar soil physical properties of objects. And after the object of target soil samples was carried into the prediction model and processed by the system, the accurate forecasting content of the target soil samples could be obtained. The system includes modules such as file operations, spectra pretreatment, sample analysis, calibrating and validating, and samples content forecasting. The system was designed to run out of equipment. The parameters and spectral data files (*.xls) of the known soil samples can be input into the system. Due to various data pretreatment being selected according to the concrete conditions, the results of predicting content will appear in the terminal and the forecasting model can be stored in the model database. The system reads the predicting models and their parameters are saved in the model database from the module interface, and then the data of the tested samples are transferred into the selected model. Finally the content of soil parameters can be predicted by the developed system. The system was programmed with Visual C++6.0 and Matlab 7.0. And the Access XP was used to create and manage the model database.
Nagayama, T.; Bailey, J. E.; Loisel, G.; ...
2016-02-05
Recently, frequency-resolved iron opacity measurements at electron temperatures of 170–200 eV and electron densities of (0.7 – 4.0) × 10 22 cm –3 revealed a 30–400% disagreement with the calculated opacities [J. E. Bailey et al., Nature (London) 517, 56 (2015)]. The discrepancies have a high impact on astrophysics, atomic physics, and high-energy density physics, and it is important to verify our understanding of the experimental platform with simulations. Reliable simulations are challenging because the temporal and spatial evolution of the source radiation and of the sample plasma are both complex and incompletely diagnosed. In this article, we describe simulationsmore » that reproduce the measured temperature and density in recent iron opacity experiments performed at the Sandia National Laboratories Z facility. The time-dependent spectral irradiance at the sample is estimated using the measured time- and space-dependent source radiation distribution, in situ source-to-sample distance measurements, and a three-dimensional (3D) view-factor code. The inferred spectral irradiance is used to drive 1D sample radiation hydrodynamics simulations. The images recorded by slit-imaged space-resolved spectrometers are modeled by solving radiation transport of the source radiation through the sample. We find that the same drive radiation time history successfully reproduces the measured plasma conditions for eight different opacity experiments. These results provide a quantitative physical explanation for the observed dependence of both temperature and density on the sample configuration. Simulated spectral images for the experiments without the FeMg sample show quantitative agreement with the measured spectral images. The agreement in spectral profile, spatial profile, and brightness provides further confidence in our understanding of the backlight-radiation time history and image formation. Furthermore, these simulations bridge the static-uniform picture of the data interpretation and the dynamic-gradient reality of the experiments, and they will allow us to quantitatively assess the impact of effects neglected in the data interpretation.« less
Demosaicking for full motion video 9-band SWIR sensor
NASA Astrophysics Data System (ADS)
Kanaev, Andrey V.; Rawhouser, Marjorie; Kutteruf, Mary R.; Yetzbacher, Michael K.; DePrenger, Michael J.; Novak, Kyle M.; Miller, Corey A.; Miller, Christopher W.
2014-05-01
Short wave infrared (SWIR) spectral imaging systems are vital for Intelligence, Surveillance, and Reconnaissance (ISR) applications because of their abilities to autonomously detect targets and classify materials. Typically the spectral imagers are incapable of providing Full Motion Video (FMV) because of their reliance on line scanning. We enable FMV capability for a SWIR multi-spectral camera by creating a repeating pattern of 3x3 spectral filters on a staring focal plane array (FPA). In this paper we present the imagery from an FMV SWIR camera with nine discrete bands and discuss image processing algorithms necessary for its operation. The main task of image processing in this case is demosaicking of the spectral bands i.e. reconstructing full spectral images with original FPA resolution from spatially subsampled and incomplete spectral data acquired with the choice of filter array pattern. To the best of author's knowledge, the demosaicking algorithms for nine or more equally sampled bands have not been reported before. Moreover all existing algorithms developed for demosaicking visible color filter arrays with less than nine colors assume either certain relationship between the visible colors, which are not valid for SWIR imaging, or presence of one color band with higher sampling rate compared to the rest of the bands, which does not conform to our spectral filter pattern. We will discuss and present results for two novel approaches to demosaicking: interpolation using multi-band edge information and application of multi-frame super-resolution to a single frame resolution enhancement of multi-spectral spatially multiplexed images.
Multi-spectral confocal microendoscope for in-vivo imaging
NASA Astrophysics Data System (ADS)
Rouse, Andrew Robert
The concept of in-vivo multi-spectral confocal microscopy is introduced. A slit-scanning multi-spectral confocal microendoscope (MCME) was built to demonstrate the technique. The MCME employs a flexible fiber-optic catheter coupled to a custom built slit-scan confocal microscope fitted with a custom built imaging spectrometer. The catheter consists of a fiber-optic imaging bundle linked to a miniature objective and focus assembly. The design and performance of the miniature objective and focus assembly are discussed. The 3mm diameter catheter may be used on its own or routed though the instrument channel of a commercial endoscope. The confocal nature of the system provides optical sectioning with 3mum lateral resolution and 30mum axial resolution. The prism based multi-spectral detection assembly is typically configured to collect 30 spectral samples over the visible chromatic range. The spectral sampling rate varies from 4nm/pixel at 490nm to 8nm/pixel at 660nm and the minimum resolvable wavelength difference varies from 7nm to 18nm over the same spectral range. Each of these characteristics are primarily dictated by the dispersive power of the prism. The MCME is designed to examine cellular structures during optical biopsy and to exploit the diagnostic information contained within the spectral domain. The primary applications for the system include diagnosis of disease in the gastro-intestinal tract and female reproductive system. Recent data from the grayscale imaging mode are presented. Preliminary multi-spectral results from phantoms, cell cultures, and excised human tissue are presented to demonstrate the potential of in-vivo multi-spectral imaging.
Reducing beam hardening effects and metal artefacts in spectral CT using Medipix3RX
NASA Astrophysics Data System (ADS)
Rajendran, K.; Walsh, M. F.; de Ruiter, N. J. A.; Chernoglazov, A. I.; Panta, R. K.; Butler, A. P. H.; Butler, P. H.; Bell, S. T.; Anderson, N. G.; Woodfield, T. B. F.; Tredinnick, S. J.; Healy, J. L.; Bateman, C. J.; Aamir, R.; Doesburg, R. M. N.; Renaud, P. F.; Gieseg, S. P.; Smithies, D. J.; Mohr, J. L.; Mandalika, V. B. H.; Opie, A. M. T.; Cook, N. J.; Ronaldson, J. P.; Nik, S. J.; Atharifard, A.; Clyne, M.; Bones, P. J.; Bartneck, C.; Grasset, R.; Schleich, N.; Billinghurst, M.
2014-03-01
This paper discusses methods for reducing beam hardening effects and metal artefacts using spectral x-ray information in biomaterial samples. A small-animal spectral scanner was operated in the 15 to 80 keV x-ray energy range for this study. We use the photon-processing features of a CdTe-Medipix3RX ASIC in charge summing mode to reduce beam hardening and associated artefacts. We present spectral data collected for metal alloy samples, its analysis using algebraic 3D reconstruction software and volume visualisation using a custom volume rendering software. The cupping effect and streak artefacts are quantified in the spectral datasets. The results show reduction in beam hardening effects and metal artefacts in the narrow high energy range acquired using the spectroscopic detector. A post-reconstruction comparison between CdTe-Medipix3RX and Si-Medipix3.1 is discussed. The raw data and processed data are made available (http://hdl.handle.net/10092/8851) for testing with other software routines.
Use Of The Diamond Cell In An Industrial Laboratory
NASA Astrophysics Data System (ADS)
Barbour, Rachael L.; Stephens, J. D.; Cameron, David G.
1989-12-01
The traditional method for recording the IR spectra of solids has been KBr pellet transmission spectroscopy. This technique has several disadvantages: sample preparation time, matrix contamination, spectral distortion, ion exchange, a limited spectral range, scattering, loss of sample integrity during grinding, etc. In recent years, diffuse reflectance, ATR, photoacoustic reflectance, and external reflectance have been used increasingly, facilitated by the high SNR of FT instruments. In many cases, the diamond cell is an attractive alternative to all of these. The spectral range is -100 -1 to the UV, excluding the 2200-2000 cm -1 region. Spectral distortion, usually a great problem with inorganics, is greatly reduced as a result of sample homogeneity (from a spectral point of view) and refractive index matching. There is no matrix contamination: scattering, background slope, and all absorption bands are from the sample. There is no ion exchange. The sample size requirements are minimal. Finally, sample preparation requires the somewhat lost. but powerful, art of microscopic examination. In some instances, there may be sample orientation or pressure induced phase changes associated with the use of the diamond cell. A common misconception is that an IR microscope is needed to use the diamond cell. In fact, ~5 minutes will suffice without a beam condenser; 1 minute is all that is needed with one. In part, this is because one usually has excellent control of the optical thickness; with experience, the cell can easily be assembled to give bands in the 0.7-1.5 absorbance range, and making the sample thinner merely involves pressing the diamonds together. Given the above, the microscope should only be used for inhomogeneous samples as one loses all information below 700 cm-1, the region of greatest value when studying inorganics. We also note that the cell can readily be moved from a mid-IR to a far-IR bench. We have moved to the point where this is the dominant sampling technique, with ATR being the next most important. Diffuse reflectance and KBr pellets are seldom used. The cell has been used on inorganics (mid and far IR) including extremely small pure mineral samples selected by hand. It is also used for polymers, polymer inclusions, filter deposits, pure (and not so puce) organics, and general "what is this stuff" samples. Examples of a wide variety of analyses will be given.
Bae, Yong Jin; Park, Kyung Man; Ahn, Sung Hee; Moon, Jeong Hee; Kim, Myung Soo
2014-08-01
Previously, we reported that MALDI spectra of peptides became reproducible when temperature was kept constant. Linear calibration curves derived from such spectral data could be used for quantification. Homogeneity of samples was one of the requirements. Among the three popular matrices used in peptide MALDI [i.e., α-cyano-4-hydroxycinnamic acid (CHCA), 2,5-dihydroxybenzoic acid (DHB), and sinapinic acid (SA)], homogeneous samples could be prepared by conventional means only for CHCA. In this work, we showed that sample preparation by micro-spotting improved the homogeneity for all three cases.
Infrared micro-spectral imaging: distinction of tissue types in axillary lymph node histology
Bird, Benjamin; Miljkovic, Milos; Romeo, Melissa J; Smith, Jennifer; Stone, Nicholas; George, Michael W; Diem, Max
2008-01-01
Background Histopathologic evaluation of surgical specimens is a well established technique for disease identification, and has remained relatively unchanged since its clinical introduction. Although it is essential for clinical investigation, histopathologic identification of tissues remains a time consuming and subjective technique, with unsatisfactory levels of inter- and intra-observer discrepancy. A novel approach for histological recognition is to use Fourier Transform Infrared (FT-IR) micro-spectroscopy. This non-destructive optical technique can provide a rapid measurement of sample biochemistry and identify variations that occur between healthy and diseased tissues. The advantage of this method is that it is objective and provides reproducible diagnosis, independent of fatigue, experience and inter-observer variability. Methods We report a method for analysing excised lymph nodes that is based on spectral pathology. In spectral pathology, an unstained (fixed or snap frozen) tissue section is interrogated by a beam of infrared light that samples pixels of 25 μm × 25 μm in size. This beam is rastered over the sample, and up to 100,000 complete infrared spectra are acquired for a given tissue sample. These spectra are subsequently analysed by a diagnostic computer algorithm that is trained by correlating spectral and histopathological features. Results We illustrate the ability of infrared micro-spectral imaging, coupled with completely unsupervised methods of multivariate statistical analysis, to accurately reproduce the histological architecture of axillary lymph nodes. By correlating spectral and histopathological features, a diagnostic algorithm was trained that allowed both accurate and rapid classification of benign and malignant tissues composed within different lymph nodes. This approach was successfully applied to both deparaffinised and frozen tissues and indicates that both intra-operative and more conventional surgical specimens can be diagnosed by this technique. Conclusion This paper provides strong evidence that automated diagnosis by means of infrared micro-spectral imaging is possible. Recent investigations within the author's laboratory upon lymph nodes have also revealed that cancers from different primary tumours provide distinctly different spectral signatures. Thus poorly differentiated and hard-to-determine cases of metastatic invasion, such as micrometastases, may additionally be identified by this technique. Finally, we differentiate benign and malignant tissues composed within axillary lymph nodes by completely automated methods of spectral analysis. PMID:18759967
Optical Characterization of Paper Aging Based on Laser-Induced Fluorescence (LIF) Spectroscopy.
Zhang, Hao; Wang, Shun; Chang, Keke; Sun, Haifeng; Guo, Qingqian; Ma, Liuzheng; Yang, Yatao; Zou, Caihong; Wang, Ling; Hu, Jiandong
2018-06-01
Paper aging and degradation are growing concerns for those who are responsible for the conservation of documents, archives, and libraries. In this study, the paper aging was investigated using laser-induced fluorescence spectroscopy (LIFS), where the fluorescence properties of 47 paper samples with different ages were explored. The paper exhibits fluorescence in the blue-green spectral region with two peaks at about 448 nm and 480 nm under the excitation of 405 nm laser. Both fluorescence peaks changed in absolute intensities and thus the ratio of peak intensities was also influenced with the increasing ages. By applying principal component analysis (PCA) and k-means clustering algorithm, all 47 paper samples were classified into nine groups based on the differences in paper age. Then the first-derivative fluorescence spectral curves were proposed to figure out the relationship between the spectral characteristic and the paper age, and two quantitative models were established based on the changes of first-derivative spectral peak at 443 nm, where one is an exponential fitting curve with an R-squared value of 0.99 and another is a linear fitting curve with an R-squared value of 0.88. The results demonstrated that the combination of fluorescence spectroscopy and PCA can be used for the classification of paper samples with different ages. Moreover, the first-derivative fluorescence spectral curves can be used to quantitatively evaluate the age-related changes of paper samples.
Infrared (2.08-14 micron) spectra of powered stony meteorites
NASA Technical Reports Server (NTRS)
Salisbury, J. W.; Daria, D. M.; Jarosewich, E.
1991-01-01
Infrared biconical reflectance spectra of 60 powdered meteorite samples, representing 50 different stony meteorites, were measured as analogues of asteroidal regolith. Representative samples were measured in directional hemispherical reflectance to assure that Kirchhoff's Law can be used to predict relative emissivity from the reflectance spectra. These spectral data confirm that the O-H fundamental absorption band near 2.9 microns is an extremely sensitive indicator of incipient alteration, which often has taken place in powdered meteorite samples exposed only to water vapor in the air. Such non-carbonaceous samples typically contain less than 1 percent water by weight. Likewise, the C-H fundamental absorption bands near 3.4 and 3.5 microns are equally sensitive indicators of contamination with volatile hydrocarbons, which can also be absorbed from the air. The heavy, macromolecular hydrocarbons native to chondrites do not display such heavy bands, making detection of these bands in remote sensing of asteroids unlikely. Despite the spectral artifacts introduced by alteration and hydrocarbon contamination, powdered stony meteorites display a wide variety of real spectral features that can be used for their identification, including residual reststrahlen bands, absorption bands, and the Christiansen feature. Researchers found that the wavelengths of the peaks or troughs of each of these spectral features can be used independently to infer meteorite composition, but the best results are obtained when the entire spectral curve is used, or at least the portion of it encompassed by the 8 to 14 micron atmospheric window, in a digital search library.
Synchronous fluorescence spectroscopy of colon neoplasia
NASA Astrophysics Data System (ADS)
Borisova, Ekaterina; Semyachkina-Glushkovskaya, Oxana; Genova, Tsanislava; Penkov, Nikolay; Terziev, Ivan; Vladimirov, Borislav; Avramov, Latchezar
2017-03-01
Synchronous fluorescence spectroscopy (SFS) is a steady-state approach that we used for evaluation of specific fluorescence characteristics of cancerous colorectal tissues. SFS allow narrowing of the fluorescence spectra received, which increase the spectral resolution and improve the analysis of the fluorescence origin in such complex objects, such as biological tissues. In our study we investigate the characteristic differences, with diagnostic meaning, in the synchronous fluorescence spectra (SFS) of cancerous and healthy colorectal tissues ex vivo using a spectrofluorimeter FluoroLog3 (HORIBA, JobinYvon, France) for obtaining of the SFS data in a broad spectral range (300-800 nm) using excitation in the range of 280-440 nm with a delta lambda between 0 and 200 nm with a 10 nm step between scanning excitation and emission data. The procedure of obtaining the investigated samples ex vivo includes their excision during surgery for removal of neoplasia lesions. After the surgical removal biological samples are transported in isothermal conditions and safekeeping solution from the hospital to the spectral laboratory, where their spectral properties were investigated. All patients received and signed written informed consent and this research is approved by Ethics committee of University Hospital "Tsaritsa Yoanna", Sofia. Histological analysis was used as "gold standard" for evaluation of tissue samples and comparison of the spectral data received.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sugiyama, K.; Fujii, T.; Matsumura, T.
2010-05-01
The chlorine concentration in concrete samples was measured by laser-induced breakdown spectroscopy (LIBS). One or two pulsed second harmonic Nd:YAG lasers ({lambda}=532 nm) were used for the generation of laser-induced breakdown, and an intensified CCD camera, spectrometer, and optical bundle fiber were used for spectral measurement. To maximize the spectral intensity of the chlorine fluorescence line at a wavelength of 837.59 nm, the time delay between laser irradiation and spectral measurement, the time delay between the two laser pulses in double-pulse measurement, and the gate width of the spectral measurement were optimized. The linear relationship between the spectral intensity ofmore » the chlorine fluorescence line and the chlorine concentration was verified for pressed samples with chlorine concentrations from 0.18 to 5.4 kg/m{sup 3}. The signal-to-noise ratio was higher than 2 for the sample with a chlorine concentration of 0.18 kg/m{sup 3} (0.008 wt. %). Thus, a chlorine concentration of 0.6 kg/m{sup 3}, at which the reinforcing bars in concrete structures start to corrode, can be detected. These results show that LIBS is effective for the quantitative measurement of chlorine concentration in concrete with high sensitivity.« less
NASA Astrophysics Data System (ADS)
Zhu, Yizheng; Li, Chengshuai
2016-03-01
Morphological assessment of spermatozoa is of critical importance for in vitro fertilization (IVF), especially intracytoplasmic sperm injection (ICSI)-based IVF. In ICSI, a single sperm cell is selected and injected into an egg to achieve fertilization. The quality of the sperm cell is found to be highly correlated to IVF success. Sperm morphology, such as shape, head birefringence and motility, among others, are typically evaluated under a microscope. Current observation relies on conventional techniques such as differential interference contrast microscopy and polarized light microscopy. Their qualitative nature, however, limits the ability to provide accurate quantitative analysis. Here, we demonstrate quantitative morphological measurement of sperm cells using two types of spectral interferometric techniques, namely spectral modulation interferometry and spectral multiplexing interferometry. Both are based on spectral-domain low coherence interferometry, which is known for its exquisite phase determination ability. While spectral modulation interferometry encodes sample phase in a single spectrum, spectral multiplexing interferometry does so for sample birefringence. Therefore they are capable of highly sensitive phase and birefringence imaging. These features suit well in the imaging of live sperm cells, which are small, dynamic objects with only low to moderate levels of phase and birefringence contrast. We will introduce the operation of both techniques and demonstrate their application to measuring the phase and birefringence morphology of sperm cells.
40 CFR 1065.245 - Sample flow meter for batch sampling.
Code of Federal Regulations, 2010 CFR
2010-07-01
... rates or total flow sampled into a batch sampling system over a test interval. You may use the... rates or total raw exhaust flow over a test interval. (b) Component requirements. We recommend that you... averaging Pitot tube, or a hot-wire anemometer. Note that your overall system for measuring sample flow must...
Improving Ramsey spectroscopy in the extreme-ultraviolet region with a random-sampling approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eramo, R.; Bellini, M.; European Laboratory for Non-linear Spectroscopy
2011-04-15
Ramsey-like techniques, based on the coherent excitation of a sample by delayed and phase-correlated pulses, are promising tools for high-precision spectroscopic tests of QED in the extreme-ultraviolet (xuv) spectral region, but currently suffer experimental limitations related to long acquisition times and critical stability issues. Here we propose a random subsampling approach to Ramsey spectroscopy that, by allowing experimentalists to reach a given spectral resolution goal in a fraction of the usual acquisition time, leads to substantial improvements in high-resolution spectroscopy and may open the way to a widespread application of Ramsey-like techniques to precision measurements in the xuv spectral region.
Low Cost Solar Array Project: Composition Measurements by Analytical Photon Catalysis
NASA Technical Reports Server (NTRS)
Sutton, D. G.; Galvan, L.; Melzer, J.; Heidner, R. F., III
1979-01-01
The applicability of the photon catalysis technique for effecting composition analysis of silicon samples was assessed. Third quarter activities were devoted to the study of impurities in silicon matrices. The evaporation process was shown to be congruent; thus, the spectral analysis of the vapor yields the composition of the bulk sample. Qualitative analysis of metal impurities in silicon was demonstrated e part per million level. Only one atomic spectral interference was noted; however, it is imperative to maintain a leak tight system due to chemical and spectral interferences caused by the presence of even minute amounts of oxygen in the active nitrogen afterglow.
MicrOmega: a VIS/NIR hyperspectral microscope for in situ analysis in space
NASA Astrophysics Data System (ADS)
Leroi, V.; Bibring, J. P.; Berthé, M.
2008-07-01
MicrOmega is an ultra miniaturized spectral microscope for in situ analysis of samples. It is composed of 2 microscopes: one with a spatial sampling of 5 μm, working in 4 color in the visible range and one NIR hyperspectral microscope in the spectral range 0.9-4 μm with a spatial sampling of 20 μm per pixel (described in this paper). MicrOmega/NIR illuminates and images samples a few mm in size and acquires the NIR spectrum of each resolved pixel in up to 600 contiguous spectral channels. The goal of this instrument is to analyse in situ the composition of collected samples at almost their grain size scale, in a non destructive way. It should be among the first set of instruments who will analyse the sample and enable other complementary analyses to be performed on it. With the spectral range and resolution chosen, a wide variety of constituents can be identified: minerals, such as pyroxene and olivine, ferric oxides, hydrated phyllosilicates, sulfates and carbonates; ices and organics. The composition of the various phases within a given sample is a critical record of its formation and evolution. Coupled to the mapping information, it provides unique clues to describe the history of the parent body. In particular, the capability to identify hydrated grains and to characterize their adjacent phases has a huge potential in the search for potential bio-relics. We will present the major instrumental principles and specifications of MicrOmega/NIR, and its expected performances in particular for the ESA/ExoMars Mission.
Ehrenfest model with large jumps in finance
NASA Astrophysics Data System (ADS)
Takahashi, Hisanao
2004-02-01
Changes (returns) in stock index prices and exchange rates for currencies are argued, based on empirical data, to obey a stable distribution with characteristic exponent α<2 for short sampling intervals and a Gaussian distribution for long sampling intervals. In order to explain this phenomenon, an Ehrenfest model with large jumps (ELJ) is introduced to explain the empirical density function of price changes for both short and long sampling intervals.
Jensen, Jacob S; Egebo, Max; Meyer, Anne S
2008-05-28
Accomplishment of fast tannin measurements is receiving increased interest as tannins are important for the mouthfeel and color properties of red wines. Fourier transform mid-infrared spectroscopy allows fast measurement of different wine components, but quantification of tannins is difficult due to interferences from spectral responses of other wine components. Four different variable selection tools were investigated for the identification of the most important spectral regions which would allow quantification of tannins from the spectra using partial least-squares regression. The study included the development of a new variable selection tool, iterative backward elimination of changeable size intervals PLS. The spectral regions identified by the different variable selection methods were not identical, but all included two regions (1485-1425 and 1060-995 cm(-1)), which therefore were concluded to be particularly important for tannin quantification. The spectral regions identified from the variable selection methods were used to develop calibration models. All four variable selection methods identified regions that allowed an improved quantitative prediction of tannins (RMSEP = 69-79 mg of CE/L; r = 0.93-0.94) as compared to a calibration model developed using all variables (RMSEP = 115 mg of CE/L; r = 0.87). Only minor differences in the performance of the variable selection methods were observed.
Visible-Infrared Hyperspectral Image Projector
NASA Technical Reports Server (NTRS)
Bolcar, Matthew
2013-01-01
The VisIR HIP generates spatially-spectrally complex scenes. The generated scenes simulate real-world targets viewed by various remote sensing instruments. The VisIR HIP consists of two subsystems: a spectral engine and a spatial engine. The spectral engine generates spectrally complex uniform illumination that spans the wavelength range between 380 nm and 1,600 nm. The spatial engine generates two-dimensional gray-scale scenes. When combined, the two engines are capable of producing two-dimensional scenes with a unique spectrum at each pixel. The VisIR HIP can be used to calibrate any spectrally sensitive remote-sensing instrument. Tests were conducted on the Wide-field Imaging Interferometer Testbed at NASA s Goddard Space Flight Center. The device is a variation of the calibrated hyperspectral image projector developed by the National Institute of Standards and Technology in Gaithersburg, MD. It uses Gooch & Housego Visible and Infrared OL490 Agile Light Sources to generate arbitrary spectra. The two light sources are coupled to a digital light processing (DLP(TradeMark)) digital mirror device (DMD) that serves as the spatial engine. Scenes are displayed on the DMD synchronously with desired spectrum. Scene/spectrum combinations are displayed in rapid succession, over time intervals that are short compared to the integration time of the system under test.
NASA Astrophysics Data System (ADS)
Tanc, Beril; Kaya, Mustafa; Gumus, Lokman; Kumral, Mustafa
2016-04-01
X-ray fluorescence (XRF) spectrometry is widely used for quantitative and semi quantitative analysis of many major, minor and trace elements in geological samples. Some advantages of the XRF method are; non-destructive sample preparation, applicability for powder, solid, paste and liquid samples and simple spectrum that are independent from chemical state. On the other hand, there are some disadvantages of the XRF methods such as poor sensitivity for low atomic number elements, matrix effect (physical matrix effects, such as fine versus course grain materials, may impact XRF performance) and interference effect (the spectral lines of elements may overlap distorting results for one or more elements). Especially, spectral interferences are very significant factors for accurate results. In this study, semi-quantitative analyzed manganese (II) oxide (MnO, 99.99%) was examined. Samples were pelleted and analyzed with XRF spectrometry (Bruker S8 Tiger). Unexpected peaks were obtained at the side of the major Mn peaks. Although sample does not contain Eu element, in results 0,3% Eu2O3 was observed. These result can occur high concentration of MnO and proximity of Mn and Eu lines. It can be eliminated by using correction equation or Mn concentration can confirm with other methods (such as Atomic absorption spectroscopy). Keywords: Spectral Interferences; Manganese (Mn); Europium (Eu); X-Ray Fluorescence Spectrometry Spectrum.
Currie, Katharine D; Rosen, Lee M; Millar, Philip J; McKelvie, Robert S; MacDonald, Maureen J
2013-06-01
Decreased heart rate variability and attenuated heart rate recovery following exercise are associated with an increased risk of mortality in cardiac patients. This study investigated the effects of 12 weeks of moderate-intensity endurance exercise (END) and a novel low-volume high-intensity interval exercise protocol (HIT) on measures of heart rate recovery and heart rate variability in patients with coronary artery disease (CAD). Fourteen males with CAD participated in 12 weeks of END or HIT training, each consisting of 2 supervised exercise sessions per week. END consisted of 30-50 min of continuous cycling at 60% peak power output (PPO). HIT involved ten 1-min intervals at 88% PPO separated by 1-min intervals at 10% PPO. Heart rate recovery at 1 min and 2 min was measured before and after training (pre- and post-training, respectively) using a submaximal exercise bout. Resting time and spectral and nonlinear domain measures of heart rate variability were calculated. Following 12 weeks of END and HIT, there was no change in heart rate recovery at 1 min (END, 40 ± 12 beats·min(-1) vs. 37 ± 19 beats·min(-1); HIT, 31 ± 8 beats·min(-1) vs. 35 ± 8 beats·min(-1); p ≥ 0.05 for pre- vs. post-training) or 2 min (END, 44 ± 18 beats·min(-1) vs. 43 ± 19 beats·min(-1); HIT, 42 ± 10 beats·min(-1) vs. 50 ± 6 beats·min(-1); p ≥ 0.05 for pre- vs. post-training). All heart rate variability indices were unchanged following END and HIT training. In conclusion, neither END nor HIT exercise programs elicited training-induced improvements in cardiac autonomic function in patients with CAD. The absence of improvements with training may be attributed to the optimal medical management and normative pretraining state of our sample.
Viana, Duarte S; Santamaría, Luis; Figuerola, Jordi
2016-02-01
Propagule retention time is a key factor in determining propagule dispersal distance and the shape of "seed shadows". Propagules dispersed by animal vectors are either ingested and retained in the gut until defecation or attached externally to the body until detachment. Retention time is a continuous variable, but it is commonly measured at discrete time points, according to pre-established sampling time-intervals. Although parametric continuous distributions have been widely fitted to these interval-censored data, the performance of different fitting methods has not been evaluated. To investigate the performance of five different fitting methods, we fitted parametric probability distributions to typical discretized retention-time data with known distribution using as data-points either the lower, mid or upper bounds of sampling intervals, as well as the cumulative distribution of observed values (using either maximum likelihood or non-linear least squares for parameter estimation); then compared the estimated and original distributions to assess the accuracy of each method. We also assessed the robustness of these methods to variations in the sampling procedure (sample size and length of sampling time-intervals). Fittings to the cumulative distribution performed better for all types of parametric distributions (lognormal, gamma and Weibull distributions) and were more robust to variations in sample size and sampling time-intervals. These estimated distributions had negligible deviations of up to 0.045 in cumulative probability of retention times (according to the Kolmogorov-Smirnov statistic) in relation to original distributions from which propagule retention time was simulated, supporting the overall accuracy of this fitting method. In contrast, fitting the sampling-interval bounds resulted in greater deviations that ranged from 0.058 to 0.273 in cumulative probability of retention times, which may introduce considerable biases in parameter estimates. We recommend the use of cumulative probability to fit parametric probability distributions to propagule retention time, specifically using maximum likelihood for parameter estimation. Furthermore, the experimental design for an optimal characterization of unimodal propagule retention time should contemplate at least 500 recovered propagules and sampling time-intervals not larger than the time peak of propagule retrieval, except in the tail of the distribution where broader sampling time-intervals may also produce accurate fits.
NASA Astrophysics Data System (ADS)
Bukina, M. N.; Bakulev, V. M.; Barmasov, A. V.; Zhakhov, A. V.; Ishchenko, A. M.
2015-06-01
The spectral luminescence properties of aqueous solutions of the Hsp70 protein are studied, the dependence of the luminescence spectrum on the excitation wavelength is revealed, and the temperature dependence of luminescence intensity of tyrosine and tryptophan residues in the temperature interval of 20-80° C is analyzed. The luminescence method is used to determine temperature interval (42-57° C) in which protein melting takes place. An increase in the fluorescence quantum yield of tryptophan and the bathochromic shift of the emission spectrum of denatured Hsp70 prove that transition takes place of tryptophanyls to the surface of the protein molecule.
Measurement of absorption and dispersion from check shot surveys
NASA Astrophysics Data System (ADS)
Ganley, D. C.; Kanasewich, E. R.
1980-10-01
The spectral ratio method for measuring absorption and also dispersion from seismic data has been examined. Corrections for frequency-dependent losses due to reflections and transmissions have been shown to be an important step in the method. Synthetic examples have been used to illustrate the method, and the method has been applied to one real data case from a sedimentary basin in the Beaufort Sea. Measured Q values were 43±2 for a depth interval of 549-1193 m and 67±6 for a depth interval of 945-1311 m. Dispersion was also measured in the data and is consistent with Futterman's model.
Svečnjak, Lidija; Prđun, Saša; Rogina, Josip; Bubalo, Dragan; Jerković, Igor
2017-10-01
Samples of Satsuma mandarin (Citrus unshiu Marc.) nectar, honey sac content and honey were analyzed by FTIR-ATR spectroscopy and reference methods. The spectral analysis allowed detection of the major chemical constituents in C. unshiu nectar-to-honey transformation pathway thus providing information on the intensity and location of the compositional changes occurring during this process. The preliminary results showed that in average more than one-third of sugar-related nectar-to-honey conversion takes place directly in the honey sac; the average sugar content (w/w) was 17.93% (nectar), 47.03% (honey sac) and 79.63% (honey). FTIR-ATR results showed great spectral similarity of analyzed honey samples and small degree variations in both sugar and water content in nectar samples. The spectral data revealed distinctive differences in the chemical composition of individual honey sac contents with the most intensive and complex absorption envelope in the spectral region between 1175 and 950cm -1 (glucose, fructose and sucrose absorption bands). Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Risky, Yanuar S.; Aulia, Yogi H.; Widayani, Prima
2017-12-01
Spectral indices variations support for rapid and accurate extracting information such as built-up density. However, the exact determination of spectral waves for built-up density extraction is lacking. This study explains and compares the capabilities of 5 variations of spectral indices in spatiotemporal built-up density mapping using Landsat-7 ETM+ and Landsat-8 OLI/TIRS in Surakarta City on 2002 and 2015. The spectral indices variations used are 3 mid-infrared (MIR) based indices such as the Normalized Difference Built-up Index (NDBI), Urban Index (UI) and Built-up and 2 visible based indices such as VrNIR-BI (visible red) and VgNIR-BI (visible green). Linear regression statistics between ground value samples from Google Earth image in 2002 and 2015 and spectral indices for determining built-up land density. Ground value used amounted to 27 samples for model and 7 samples for accuracy test. The classification of built-up density mapping is divided into 9 classes: unclassified, 0-12.5%, 12.5-25%, 25-37.5%, 37.5-50%, 50-62.5%, 62.5-75%, 75-87.5% and 87.5-100 %. Accuracy of built-up land density mapping in 2002 and 2015 using VrNIR-BI (81,823% and 73.235%), VgNIR-BI (78.934% and 69.028%), NDBI (34.870% and 74.365%), UI (43.273% and 64.398%) and Built-up (59.755% and 72.664%). Based all spectral indices, Surakarta City on 2000-2015 has increased of built-up land density. VgNIR-BI has better capabilities for built-up land density mapping on Landsat-7 ETM + and Landsat-8 OLI/TIRS.
Prinos, Scott T.; Valderrama, Robert
2015-01-01
At five of the monitoring-well cluster locations, a long-screened well was also installed for monitoring and comparison purposes. These long-screened wells are 160 to 200 ft deep, and have open intervals ranging from 145 to 185 ft in length. Water samples were collected at depth intervals of about 5 to 10 ft, using 3-ft-long straddle packers to isolate each sampling interval. The results of monitoring conducted using these long-screened interval wells were generally too variable to identify any changes that might be associated with the seepage barrier. Samples from one of these long-screened interval wells failed to detect the saltwater interface evident in samples and TSEMIL datasets from a collocated well cluster. This failure may have been caused by downward flow of freshwater from above the saltwater interface in the well bore.
Hu, Zhi-yu; Zhang, Lei; Ma, Wei-guang; Yan, Xiao-juan; Li, Zhi-xin; Zhang, Yong-zhi; Wang, Le; Dong, Lei; Yin, Wang-bao; Jia, Suo-tang
2012-03-01
Self-designed identifying software for LIBS spectral line was introduced. Being integrated with LabVIEW, the soft ware can smooth spectral lines and pick peaks. The second difference and threshold methods were employed. Characteristic spectrum of several elements matches the NIST database, and realizes automatic spectral line identification and qualitative analysis of the basic composition of sample. This software can analyze spectrum handily and rapidly. It will be a useful tool for LIBS.
Remotely sensed and laboratory spectral signatures of an ocean-dumped acid waste
NASA Technical Reports Server (NTRS)
Lewis, B. W.; Collins, V. G.
1977-01-01
An ocean-dumped acid waste plume was studied by using a rapid scanning spectrometer to remotely measure ocean radiance from a helicopter. The results of these studies are presented and compared with results from sea truth samples and laboratory experiments. An ocean spectral reflectance signature and a laboratory spectral transmission signature were established for the iron-acid waste pollutant. The spectrally and chemically significant component of the acid waste pollutant was determined to be ferric iron.
Semiclassical analysis of spectral singularities and their applications in optics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mostafazadeh, Ali
2011-08-15
Motivated by possible applications of spectral singularities in optics, we develop a semiclassical method of computing spectral singularities. We use this method to examine the spectral singularities of a planar slab gain medium whose gain coefficient varies due to the exponential decay of the intensity of the pumping beam inside the medium. For both singly and doublypumped samples, we obtain universal upper bounds on the decay constant beyond which no lasing occurs. Furthermore, we show that the dependence of the wavelength of the spectral singularities on the value of the decay constant is extremely mild. This is an indication ofmore » the stability of optical spectral singularities.« less
Estimating fluvial wood discharge from timelapse photography with varying sampling intervals
NASA Astrophysics Data System (ADS)
Anderson, N. K.
2013-12-01
There is recent focus on calculating wood budgets for streams and rivers to help inform management decisions, ecological studies and carbon/nutrient cycling models. Most work has measured in situ wood in temporary storage along stream banks or estimated wood inputs from banks. Little effort has been employed monitoring and quantifying wood in transport during high flows. This paper outlines a procedure for estimating total seasonal wood loads using non-continuous coarse interval sampling and examines differences in estimation between sampling at 1, 5, 10 and 15 minutes. Analysis is performed on wood transport for the Slave River in Northwest Territories, Canada. Relative to the 1 minute dataset, precision decreased by 23%, 46% and 60% for the 5, 10 and 15 minute datasets, respectively. Five and 10 minute sampling intervals provided unbiased equal variance estimates of 1 minute sampling, whereas 15 minute intervals were biased towards underestimation by 6%. Stratifying estimates by day and by discharge increased precision over non-stratification by 4% and 3%, respectively. Not including wood transported during ice break-up, the total minimum wood load estimated at this site is 3300 × 800$ m3 for the 2012 runoff season. The vast majority of the imprecision in total wood volumes came from variance in estimating average volume per log. Comparison of proportions and variance across sample intervals using bootstrap sampling to achieve equal n. Each trial was sampled for n=100, 10,000 times and averaged. All trials were then averaged to obtain an estimate for each sample interval. Dashed lines represent values from the one minute dataset.
Confidence intervals for correlations when data are not normal.
Bishara, Anthony J; Hittner, James B
2017-02-01
With nonnormal data, the typical confidence interval of the correlation (Fisher z') may be inaccurate. The literature has been unclear as to which of several alternative methods should be used instead, and how extreme a violation of normality is needed to justify an alternative. Through Monte Carlo simulation, 11 confidence interval methods were compared, including Fisher z', two Spearman rank-order methods, the Box-Cox transformation, rank-based inverse normal (RIN) transformation, and various bootstrap methods. Nonnormality often distorted the Fisher z' confidence interval-for example, leading to a 95 % confidence interval that had actual coverage as low as 68 %. Increasing the sample size sometimes worsened this problem. Inaccurate Fisher z' intervals could be predicted by a sample kurtosis of at least 2, an absolute sample skewness of at least 1, or significant violations of normality hypothesis tests. Only the Spearman rank-order and RIN transformation methods were universally robust to nonnormality. Among the bootstrap methods, an observed imposed bootstrap came closest to accurate coverage, though it often resulted in an overly long interval. The results suggest that sample nonnormality can justify avoidance of the Fisher z' interval in favor of a more robust alternative. R code for the relevant methods is provided in supplementary materials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clark, Darin P.; Badea, Cristian T., E-mail: cristian.badea@duke.edu; Lee, Chang-Lung
Purpose: X-ray computed tomography (CT) is widely used, both clinically and preclinically, for fast, high-resolution anatomic imaging; however, compelling opportunities exist to expand its use in functional imaging applications. For instance, spectral information combined with nanoparticle contrast agents enables quantification of tissue perfusion levels, while temporal information details cardiac and respiratory dynamics. The authors propose and demonstrate a projection acquisition and reconstruction strategy for 5D CT (3D + dual energy + time) which recovers spectral and temporal information without substantially increasing radiation dose or sampling time relative to anatomic imaging protocols. Methods: The authors approach the 5D reconstruction problem withinmore » the framework of low-rank and sparse matrix decomposition. Unlike previous work on rank-sparsity constrained CT reconstruction, the authors establish an explicit rank-sparse signal model to describe the spectral and temporal dimensions. The spectral dimension is represented as a well-sampled time and energy averaged image plus regularly undersampled principal components describing the spectral contrast. The temporal dimension is represented as the same time and energy averaged reconstruction plus contiguous, spatially sparse, and irregularly sampled temporal contrast images. Using a nonlinear, image domain filtration approach, the authors refer to as rank-sparse kernel regression, the authors transfer image structure from the well-sampled time and energy averaged reconstruction to the spectral and temporal contrast images. This regularization strategy strictly constrains the reconstruction problem while approximately separating the temporal and spectral dimensions. Separability results in a highly compressed representation for the 5D data in which projections are shared between the temporal and spectral reconstruction subproblems, enabling substantial undersampling. The authors solved the 5D reconstruction problem using the split Bregman method and GPU-based implementations of backprojection, reprojection, and kernel regression. Using a preclinical mouse model, the authors apply the proposed algorithm to study myocardial injury following radiation treatment of breast cancer. Results: Quantitative 5D simulations are performed using the MOBY mouse phantom. Twenty data sets (ten cardiac phases, two energies) are reconstructed with 88 μm, isotropic voxels from 450 total projections acquired over a single 360° rotation. In vivo 5D myocardial injury data sets acquired in two mice injected with gold and iodine nanoparticles are also reconstructed with 20 data sets per mouse using the same acquisition parameters (dose: ∼60 mGy). For both the simulations and the in vivo data, the reconstruction quality is sufficient to perform material decomposition into gold and iodine maps to localize the extent of myocardial injury (gold accumulation) and to measure cardiac functional metrics (vascular iodine). Their 5D CT imaging protocol represents a 95% reduction in radiation dose per cardiac phase and energy and a 40-fold decrease in projection sampling time relative to their standard imaging protocol. Conclusions: Their 5D CT data acquisition and reconstruction protocol efficiently exploits the rank-sparse nature of spectral and temporal CT data to provide high-fidelity reconstruction results without increased radiation dose or sampling time.« less
Spectrotemporal CT data acquisition and reconstruction at low dose
Clark, Darin P.; Lee, Chang-Lung; Kirsch, David G.; Badea, Cristian T.
2015-01-01
Purpose: X-ray computed tomography (CT) is widely used, both clinically and preclinically, for fast, high-resolution anatomic imaging; however, compelling opportunities exist to expand its use in functional imaging applications. For instance, spectral information combined with nanoparticle contrast agents enables quantification of tissue perfusion levels, while temporal information details cardiac and respiratory dynamics. The authors propose and demonstrate a projection acquisition and reconstruction strategy for 5D CT (3D + dual energy + time) which recovers spectral and temporal information without substantially increasing radiation dose or sampling time relative to anatomic imaging protocols. Methods: The authors approach the 5D reconstruction problem within the framework of low-rank and sparse matrix decomposition. Unlike previous work on rank-sparsity constrained CT reconstruction, the authors establish an explicit rank-sparse signal model to describe the spectral and temporal dimensions. The spectral dimension is represented as a well-sampled time and energy averaged image plus regularly undersampled principal components describing the spectral contrast. The temporal dimension is represented as the same time and energy averaged reconstruction plus contiguous, spatially sparse, and irregularly sampled temporal contrast images. Using a nonlinear, image domain filtration approach, the authors refer to as rank-sparse kernel regression, the authors transfer image structure from the well-sampled time and energy averaged reconstruction to the spectral and temporal contrast images. This regularization strategy strictly constrains the reconstruction problem while approximately separating the temporal and spectral dimensions. Separability results in a highly compressed representation for the 5D data in which projections are shared between the temporal and spectral reconstruction subproblems, enabling substantial undersampling. The authors solved the 5D reconstruction problem using the split Bregman method and GPU-based implementations of backprojection, reprojection, and kernel regression. Using a preclinical mouse model, the authors apply the proposed algorithm to study myocardial injury following radiation treatment of breast cancer. Results: Quantitative 5D simulations are performed using the MOBY mouse phantom. Twenty data sets (ten cardiac phases, two energies) are reconstructed with 88 μm, isotropic voxels from 450 total projections acquired over a single 360° rotation. In vivo 5D myocardial injury data sets acquired in two mice injected with gold and iodine nanoparticles are also reconstructed with 20 data sets per mouse using the same acquisition parameters (dose: ∼60 mGy). For both the simulations and the in vivo data, the reconstruction quality is sufficient to perform material decomposition into gold and iodine maps to localize the extent of myocardial injury (gold accumulation) and to measure cardiac functional metrics (vascular iodine). Their 5D CT imaging protocol represents a 95% reduction in radiation dose per cardiac phase and energy and a 40-fold decrease in projection sampling time relative to their standard imaging protocol. Conclusions: Their 5D CT data acquisition and reconstruction protocol efficiently exploits the rank-sparse nature of spectral and temporal CT data to provide high-fidelity reconstruction results without increased radiation dose or sampling time. PMID:26520724
Zhang, Libing; Lu, Zhou; Velarde, Luis; ...
2015-03-03
Both the C–H and O–H region spectra of crystalline cellulose were studied using the sub-wavenumber high-resolution broadband sum frequency generation vibrational spectroscopy (HR-BB-SFG-VS) for the first time. The resolution of HR-BB-SFG-VS is about 10-times better than conventional scanning SFG-VS and has the capability of measuring the intrinsic spectral lineshape and revealing many more spectral details. With HR-BB-SFG-VS, we found that in cellulose samples from different sources, including Avicel and cellulose crystals isolated from algae Valonia (Iα) and tunicates (Iβ), the spectral signatures in the O–H region were unique for the two allomorphs, i.e. Iα and Iβ, while the spectral signaturesmore » in the C–H regions varied in all samples examined. Even though the origin of the different spectral signatures of the crystalline cellulose in the O–H and C–H vibrational frequency regions are yet to be correlated to the structure of cellulose, these results lead to new spectroscopic methods and opportunities to classify and to understand the basic crystalline structures, as well as variations in polymorphism of the crystalline cellulose.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Libing; Lu, Zhou; Velarde, Luis
Both the C–H and O–H region spectra of crystalline cellulose were studied using the sub-wavenumber high-resolution broadband sum frequency generation vibrational spectroscopy (HR-BB-SFG-VS) for the first time. The resolution of HR-BB-SFG-VS is about 10-times better than conventional scanning SFG-VS and has the capability of measuring the intrinsic spectral lineshape and revealing many more spectral details. With HR-BB-SFG-VS, we found that in cellulose samples from different sources, including Avicel and cellulose crystals isolated from algae Valonia (Iα) and tunicates (Iβ), the spectral signatures in the O–H region were unique for the two allomorphs, i.e. Iα and Iβ, while the spectral signaturesmore » in the C–H regions varied in all samples examined. Even though the origin of the different spectral signatures of the crystalline cellulose in the O–H and C–H vibrational frequency regions are yet to be correlated to the structure of cellulose, these results lead to new spectroscopic methods and opportunities to classify and to understand the basic crystalline structures, as well as variations in polymorphism of the crystalline cellulose.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kapahi, V.K.; Kulkarni, V.K.
1990-05-01
VLA observations of a complete subset of the Leiden-Berkeley Deep Survey sources that have S(1.4 GHz) greater than 10 mJy and are not optically identified down to F=22 mag are reported. By comparing the spectral and structural properties of the sources with samples from the literature, an attempt was made to disentangle the luminosity and redshift dependence of the spectral indices of extended emission in radio galaxies and of the incidence of compact steep-spectrum sources. It is found that the fraction of compact sources among those with a steep spectrum is related primarily to redshift, being much larger at highmore » redshifts for sources of similar radio luminosity. Only a weak and marginally significant dependence of spectral indices of the extended sources on luminosity and redshift is found in samples selected at 1.4 and 2.7 GHz. It is pointed out that the much stronger correlation of spectral indices with luminosity may be arising partly from spectral curvature, and partly due to the preferential inclusion of very steep-spectrum sources from high redshift in low-frequency surveys. 54 refs.« less
Method and apparatus for measuring film spectral properties
Forrest, Stephen R.; Burrows, Paul E.; Garbuzov, Dmitri Z.; Bulovic, Vladimir
1999-12-21
Film spectral properties are measured by projecting chopped monochromatic light onto a luminescent film sample deposited on a substrate, and coupling through use of immersion oil the reflection of light therefrom to a light detector.
Alternative Confidence Interval Methods Used in the Diagnostic Accuracy Studies
Gülhan, Orekıcı Temel
2016-01-01
Background/Aim. It is necessary to decide whether the newly improved methods are better than the standard or reference test or not. To decide whether the new diagnostics test is better than the gold standard test/imperfect standard test, the differences of estimated sensitivity/specificity are calculated with the help of information obtained from samples. However, to generalize this value to the population, it should be given with the confidence intervals. The aim of this study is to evaluate the confidence interval methods developed for the differences between the two dependent sensitivity/specificity values on a clinical application. Materials and Methods. In this study, confidence interval methods like Asymptotic Intervals, Conditional Intervals, Unconditional Interval, Score Intervals, and Nonparametric Methods Based on Relative Effects Intervals are used. Besides, as clinical application, data used in diagnostics study by Dickel et al. (2010) has been taken as a sample. Results. The results belonging to the alternative confidence interval methods for Nickel Sulfate, Potassium Dichromate, and Lanolin Alcohol are given as a table. Conclusion. While preferring the confidence interval methods, the researchers have to consider whether the case to be compared is single ratio or dependent binary ratio differences, the correlation coefficient between the rates in two dependent ratios and the sample sizes. PMID:27478491
Alternative Confidence Interval Methods Used in the Diagnostic Accuracy Studies.
Erdoğan, Semra; Gülhan, Orekıcı Temel
2016-01-01
Background/Aim. It is necessary to decide whether the newly improved methods are better than the standard or reference test or not. To decide whether the new diagnostics test is better than the gold standard test/imperfect standard test, the differences of estimated sensitivity/specificity are calculated with the help of information obtained from samples. However, to generalize this value to the population, it should be given with the confidence intervals. The aim of this study is to evaluate the confidence interval methods developed for the differences between the two dependent sensitivity/specificity values on a clinical application. Materials and Methods. In this study, confidence interval methods like Asymptotic Intervals, Conditional Intervals, Unconditional Interval, Score Intervals, and Nonparametric Methods Based on Relative Effects Intervals are used. Besides, as clinical application, data used in diagnostics study by Dickel et al. (2010) has been taken as a sample. Results. The results belonging to the alternative confidence interval methods for Nickel Sulfate, Potassium Dichromate, and Lanolin Alcohol are given as a table. Conclusion. While preferring the confidence interval methods, the researchers have to consider whether the case to be compared is single ratio or dependent binary ratio differences, the correlation coefficient between the rates in two dependent ratios and the sample sizes.
NASA Astrophysics Data System (ADS)
Gordon, Devin A.; DeNoyer, Lin; Meyer, Corey W.; Sweet, Noah W.; Burns, David M.; Bruckman, Laura S.; French, Roger H.
2017-08-01
Poly(ethylene-terephthalate) (PET) film is widely used in photovoltaic module backsheets for its dielectric break- down strength, and in applications requiring high optical clarity for its high transmission in the visible region. However, PET degrades and loses optical clarity under exposure to ultraviolet (UV) irradiance, heat, and moisture. Stabilizers are often included in PET formulation to increase its longevity; however, even these are subject to degradation and further reduce optical clarity. To study the weathering induced changes in the optical properties in PET films, samples of a UV-stabilized grade of PET were exposed to heat, moisture, and UV irradiance as prescribed by ASTM-G154 Cycle 4 for 168 hour time intervals. UV-Vis reflection and transmission spectra were collected via Multi-Angle, Polarization-Dependent, Reflection, Transmission, and Scattering (MaPd:RTS) spectroscopy after each exposure interval. The resulting spectra were used to calculate the complex index of refraction throughout the UV-Vis spectral region via an iterative optimization process based upon the Fresnel equations. The index of refraction and extinction coefficient were found to vary throughout the UV-Vis region with time under exposure. The spectra were also used to investigate changes in light scattering behavior with increasing exposure time. The intensity of scattered light was found to increase at higher angles with time under exposure.
NASA Astrophysics Data System (ADS)
Fu, Haiyan; Yin, Qiaobo; Xu, Lu; Wang, Weizheng; Chen, Feng; Yang, Tianming
2017-07-01
The origins and authenticity against frauds are two essential aspects of food quality. In this work, a comprehensive quality evaluation method by FT-NIR spectroscopy and chemometrics were suggested to address the geographical origins and authentication of Chinese Ganoderma lucidum (GL). Classification for 25 groups of GL samples (7 common species from 15 producing areas) was performed using near-infrared spectroscopy and interval-combination One-Versus-One least squares support vector machine (IC-OVO-LS-SVM). Untargeted analysis of 4 adulterants of cheaper mushrooms was performed by one-class partial least squares (OCPLS) modeling for each of the 7 GL species. After outlier diagnosis and comparing the influences of different preprocessing methods and spectral intervals on classification, IC-OVO-LS-SVM with standard normal variate (SNV) spectra obtained a total classification accuracy of 0.9317, an average sensitivity and specificity of 0.9306 and 0.9971, respectively. With SNV or second-order derivative (D2) spectra, OCPLS could detect at least 2% or more doping levels of adulterants for 5 of the 7 GL species and 5% or more doping levels for the other 2 GL species. This study demonstrates the feasibility of using new chemometrics and NIR spectroscopy for fine classification of GL geographical origins and species as well as for untargeted analysis of multiple adulterants.
PHOBOS AS A D-TYPE CAPTURED ASTEROID, SPECTRAL MODELING FROM 0.25 TO 4.0 μm
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pajola, M.; Magrin, S.; Bertini, I.
This paper describes the spectral modeling of the surface of Phobos in the wavelength range between 0.25 and 4.0 μm. We use complementary data to cover this spectral range: the OSIRIS (Optical, Spectroscopic, and Infrared Remote Imaging System on board the ESA Rosetta spacecraft) reflectance spectrum that Pajola et al. merged with the VSK-KRFM-ISM (Videospectrometric Camera (VSK)-Combined Radiometer and Photometer for Mars (KRFM)-Imaging Spectrometer for Mars (ISM) on board the USSR Phobos 2 spacecraft) spectra by Murchie and Erard and the IRTF (NASA Infrared Telescope Facility, Hawaii, USA) spectra published by Rivkin et al. The OSIRIS data allow the characterizationmore » of an area of Phobos covering from 86.°8 N to 90° S in latitude and from 126° W to 286° W in longitude. This corresponds chiefly to the trailing hemisphere, but with a small sampling of the leading hemisphere as well. We compared the OSIRIS results with the Trojan D-type asteroid 624 Hektor and show that the overall slope and curvature of the two bodies over the common wavelength range are very similar. This favors Phobos being a captured D-type asteroid as previously suggested. We modeled the OSIRIS data using two models, the first one with a composition that includes organic carbonaceous material, serpentine, olivine, and basalt glass, and the second one consisting of Tagish Lake meteorite and magnesium-rich pyroxene glass. The results of these models were extended to longer wavelengths to compare the VSK-KRFM-ISM and IRTF data. The overall shape of the second model spectrum between 0.25 and 4.0 μm shows curvature and an albedo level that match both the OSIRIS and Murchie and Erard data and the Rivkin et al. data much better than the first model. The large interval fit is encouraging and adds weight to this model, making it our most promising fit for Phobos. Since Tagish Lake is commonly used as a spectral analog for D-type asteroids, this provides additional support for compositional similarities between Phobos and D-type asteroids.« less
NASA Astrophysics Data System (ADS)
Saluja, Ridhi; Garg, J. K.
2017-10-01
Wetlands, one of the most productive ecosystems on Earth, perform myriad ecological functions and provide a host of ecological services. Despite their ecological and economic values, wetlands have experienced significant degradation during the last century and the trend continues. Hyperspectral sensors provide opportunities to map and monitor macrophyte species within wetlands for their management and conservation. In this study, an attempt has been made to evaluate the potential of narrowband spectroradiometer data in discriminating wetland macrophytes during different seasons. main objectives of the research were (1) to determine whether macrophyte species could be discriminated based on in-situ hyperspectral reflectance collected over different seasons and at each measured waveband (400-950nm), (2) to compare the effectiveness of spectral reflectance and spectral indices in discriminating macrophyte species, and (3) to identify spectral wavelengths that are most sensitive in discriminating macrophyte species. Spectral characteristics of dominant wetland macrophyte species were collected seasonally using SVC GER 1500 portable spectroradiometer over the 400 to 1050nm spectral range at 1.5nm interval, at the Bhindawas wetland in the state of Haryana, India. Hyperspectral observations were pre-processed and subjected to statistical analysis, which involved a two-step approach including feature selection (ANOVA and KW test) and feature extraction (LDA and PCA). Statistical analysis revealed that the most influential wavelengths for discrimination were distributed along the spectral profile from visible to the near-infrared regions. The results suggest that hyperspectral data can be used discriminate wetland macrophyte species working as an effective tool for advanced mapping and monitoring of wetlands.
Ocean wavenumber estimation from wave-resolving time series imagery
Plant, N.G.; Holland, K.T.; Haller, M.C.
2008-01-01
We review several approaches that have been used to estimate ocean surface gravity wavenumbers from wave-resolving remotely sensed image sequences. Two fundamentally different approaches that utilize these data exist. A power spectral density approach identifies wavenumbers where image intensity variance is maximized. Alternatively, a cross-spectral correlation approach identifies wavenumbers where intensity coherence is maximized. We develop a solution to the latter approach based on a tomographic analysis that utilizes a nonlinear inverse method. The solution is tolerant to noise and other forms of sampling deficiency and can be applied to arbitrary sampling patterns, as well as to full-frame imagery. The solution includes error predictions that can be used for data retrieval quality control and for evaluating sample designs. A quantitative analysis of the intrinsic resolution of the method indicates that the cross-spectral correlation fitting improves resolution by a factor of about ten times as compared to the power spectral density fitting approach. The resolution analysis also provides a rule of thumb for nearshore bathymetry retrievals-short-scale cross-shore patterns may be resolved if they are about ten times longer than the average water depth over the pattern. This guidance can be applied to sample design to constrain both the sensor array (image resolution) and the analysis array (tomographic resolution). ?? 2008 IEEE.
NASA Astrophysics Data System (ADS)
Max-Moerbeck, W.; Richards, J. L.; Hovatta, T.; Pavlidou, V.; Pearson, T. J.; Readhead, A. C. S.
2014-11-01
We present a practical implementation of a Monte Carlo method to estimate the significance of cross-correlations in unevenly sampled time series of data, whose statistical properties are modelled with a simple power-law power spectral density. This implementation builds on published methods; we introduce a number of improvements in the normalization of the cross-correlation function estimate and a bootstrap method for estimating the significance of the cross-correlations. A closely related matter is the estimation of a model for the light curves, which is critical for the significance estimates. We present a graphical and quantitative demonstration that uses simulations to show how common it is to get high cross-correlations for unrelated light curves with steep power spectral densities. This demonstration highlights the dangers of interpreting them as signs of a physical connection. We show that by using interpolation and the Hanning sampling window function we are able to reduce the effects of red-noise leakage and to recover steep simple power-law power spectral densities. We also introduce the use of a Neyman construction for the estimation of the errors in the power-law index of the power spectral density. This method provides a consistent way to estimate the significance of cross-correlations in unevenly sampled time series of data.
NASA Astrophysics Data System (ADS)
Klus, Jakub; Pořízka, Pavel; Prochazka, David; Mikysek, Petr; Novotný, Jan; Novotný, Karel; Slobodník, Marek; Kaiser, Jozef
2017-05-01
This paper presents a novel approach for processing the spectral information obtained from high-resolution elemental mapping performed by means of Laser-Induced Breakdown Spectroscopy. The proposed methodology is aimed at the description of possible elemental associations within a heterogeneous sample. High-resolution elemental mapping provides a large number of measurements. Moreover, typical laser-induced plasma spectrum consists of several thousands of spectral variables. Analysis of heterogeneous samples, where valuable information is hidden in a limited fraction of sample mass, requires special treatment. The sample under study is a sandstone-hosted uranium ore that shows irregular distribution of ore elements such as zirconium, titanium, uranium and niobium. Presented processing methodology shows the way to reduce the dimensionality of data and retain the spectral information by utilizing self-organizing maps (SOM). The spectral information from SOM is processed further to detect either simultaneous or isolated presence of elements. Conclusions suggested by SOM are in good agreement with geological studies of mineralization phases performed at the deposit. Even deeper investigation of the SOM results enables discrimination of interesting measurements and reveals new possibilities in the visualization of chemical mapping information. Suggested approach improves the description of elemental associations in mineral phases, which is crucial for the mining industry.
Salinet, João L; Masca, Nicholas; Stafford, Peter J; Ng, G André; Schlindwein, Fernando S
2016-03-08
Areas with high frequency activity within the atrium are thought to be 'drivers' of the rhythm in patients with atrial fibrillation (AF) and ablation of these areas seems to be an effective therapy in eliminating DF gradient and restoring sinus rhythm. Clinical groups have applied the traditional FFT-based approach to generate the three-dimensional dominant frequency (3D DF) maps during electrophysiology (EP) procedures but literature is restricted on using alternative spectral estimation techniques that can have a better frequency resolution that FFT-based spectral estimation. Autoregressive (AR) model-based spectral estimation techniques, with emphasis on selection of appropriate sampling rate and AR model order, were implemented to generate high-density 3D DF maps of atrial electrograms (AEGs) in persistent atrial fibrillation (persAF). For each patient, 2048 simultaneous AEGs were recorded for 20.478 s-long segments in the left atrium (LA) and exported for analysis, together with their anatomical locations. After the DFs were identified using AR-based spectral estimation, they were colour coded to produce sequential 3D DF maps. These maps were systematically compared with maps found using the Fourier-based approach. 3D DF maps can be obtained using AR-based spectral estimation after AEGs downsampling (DS) and the resulting maps are very similar to those obtained using FFT-based spectral estimation (mean 90.23 %). There were no significant differences between AR techniques (p = 0.62). The processing time for AR-based approach was considerably shorter (from 5.44 to 5.05 s) when lower sampling frequencies and model order values were used. Higher levels of DS presented higher rates of DF agreement (sampling frequency of 37.5 Hz). We have demonstrated the feasibility of using AR spectral estimation methods for producing 3D DF maps and characterised their differences to the maps produced using the FFT technique, offering an alternative approach for 3D DF computation in human persAF studies.
The optical and near-infrared colors of galaxies, 1: The photometric data
NASA Technical Reports Server (NTRS)
Bershady, Matthew A.; Hereld, Mark; Kron, Richard G.; Koo, David C.; Munn, Jeffrey A.; Majewski, Steven R.
1994-01-01
We present optical and near-infrared photometry and spectroscopic redshifts of a well defined sample of 171 field galaxies selected from three high galactic latitude fields. This data set forms the basis for subsequent studies to characterize the trends, dispersion, and evolution of rest-frame colors and image structure. A subset of 143 galaxies constitutes a magnitude-limited sample to B approx. 19.9-20.75 (depending on field), with a median redshift of 0.14, and a maximum redshift of 0.54. This subset is statistically representative in its sampling of the apparent color distribution of galaxies. Thirty six galaxies were selected to have the reddest red-optical colors in two redshift intervals between 0.2 less than z less than 0.3. Photometric passbands are similar to U, B, V, I, and K, and sample galaxy spectral energy distributions between 0.37 and 2.2 micrometers in the observed frame, or down to 0.26 micrometers in the rest frame for the most distant galaxies. B and K images of the entire sample are assembled to form the first optical and near-infrared atlas of a statistically-representative sample of field galaxies. We discuss techniques for faint field-galaxy photometry, including a working definition of a total magnitude, and a method for matching magnitudes in different passbands and different seeing conditions to ensure reliable, integrated colors. Photographic saturation, which substantially affects the brightest 12% of our sample in the optical bands, is corrected with a model employing measured plate-density distributions for each galaxy, calibrated via similar measurements for stars as a function of known saturation level. Both the relative and absolute calibration of our photometry are demonstrated.
Characterization of protein and carbohydrate mid-IR spectral features in crop residues
NASA Astrophysics Data System (ADS)
Xin, Hangshu; Zhang, Yonggen; Wang, Mingjun; Li, Zhongyu; Wang, Zhibo; Yu, Peiqiang
2014-08-01
To the best of our knowledge, a few studies have been conducted on inherent structure spectral traits related to biopolymers of crop residues. The objective of this study was to characterize protein and carbohydrate structure spectral features of three field crop residues (rice straw, wheat straw and millet straw) in comparison with two crop vines (peanut vine and pea vine) by using Fourier transform infrared spectroscopy (FTIR) technique with attenuated total reflectance (ATR). Also, multivariate analyses were performed on spectral data sets within the regions mainly related to protein and carbohydrate in this study. The results showed that spectral differences existed in mid-IR peak intensities that are mainly related to protein and carbohydrate among these crop residue samples. With regard to protein spectral profile, peanut vine showed the greatest mid-IR band intensities that are related to protein amide and protein secondary structures, followed by pea vine and the rest three field crop straws. The crop vines had 48-134% higher spectral band intensity than the grain straws in spectral features associated with protein. Similar trends were also found in the bands that are mainly related to structural carbohydrates (such as cellulosic compounds). However, the field crop residues had higher peak intensity in total carbohydrates region than the crop vines. Furthermore, spectral ratios varied among the residue samples, indicating that these five crop residues had different internal structural conformation. However, multivariate spectral analyses showed that structural similarities still exhibited among crop residues in the regions associated with protein biopolymers and carbohydrate. Further study is needed to find out whether there is any relationship between spectroscopic information and nutrition supply in various kinds of crop residue when fed to animals.
Characterization of protein and carbohydrate mid-IR spectral features in crop residues.
Xin, Hangshu; Zhang, Yonggen; Wang, Mingjun; Li, Zhongyu; Wang, Zhibo; Yu, Peiqiang
2014-08-14
To the best of our knowledge, a few studies have been conducted on inherent structure spectral traits related to biopolymers of crop residues. The objective of this study was to characterize protein and carbohydrate structure spectral features of three field crop residues (rice straw, wheat straw and millet straw) in comparison with two crop vines (peanut vine and pea vine) by using Fourier transform infrared spectroscopy (FTIR) technique with attenuated total reflectance (ATR). Also, multivariate analyses were performed on spectral data sets within the regions mainly related to protein and carbohydrate in this study. The results showed that spectral differences existed in mid-IR peak intensities that are mainly related to protein and carbohydrate among these crop residue samples. With regard to protein spectral profile, peanut vine showed the greatest mid-IR band intensities that are related to protein amide and protein secondary structures, followed by pea vine and the rest three field crop straws. The crop vines had 48-134% higher spectral band intensity than the grain straws in spectral features associated with protein. Similar trends were also found in the bands that are mainly related to structural carbohydrates (such as cellulosic compounds). However, the field crop residues had higher peak intensity in total carbohydrates region than the crop vines. Furthermore, spectral ratios varied among the residue samples, indicating that these five crop residues had different internal structural conformation. However, multivariate spectral analyses showed that structural similarities still exhibited among crop residues in the regions associated with protein biopolymers and carbohydrate. Further study is needed to find out whether there is any relationship between spectroscopic information and nutrition supply in various kinds of crop residue when fed to animals. Copyright © 2014 Elsevier B.V. All rights reserved.
Effect of acoustic similarity on short-term auditory memory in the monkey
Scott, Brian H.; Mishkin, Mortimer; Yin, Pingbo
2013-01-01
Recent evidence suggests that the monkey’s short-term memory in audition depends on a passively retained sensory trace as opposed to a trace reactivated from long-term memory for use in working memory. Reliance on a passive sensory trace could render memory particularly susceptible to confusion between sounds that are similar in some acoustic dimension. If so, then in delayed matching-to-sample, the monkey’s performance should be predicted by the similarity in the salient acoustic dimension between the sample and subsequent test stimulus, even at very short delays. To test this prediction and isolate the acoustic features relevant to short-term memory, we examined the pattern of errors made by two rhesus monkeys performing a serial, auditory delayed match-to-sample task with interstimulus intervals of 1 s. The analysis revealed that false-alarm errors did indeed result from similarity-based confusion between the sample and the subsequent nonmatch stimuli. Manipulation of the stimuli showed that removal of spectral cues was more disruptive to matching behavior than removal of temporal cues. In addition, the effect of acoustic similarity on false-alarm response was stronger at the first nonmatch stimulus than at the second one. This pattern of errors would be expected if the first nonmatch stimulus overwrote the sample’s trace, and suggests that the passively retained trace is not only vulnerable to similarity-based confusion but is also highly susceptible to overwriting. PMID:23376550
What controls the variability of oxygen in the subpolar North Pacific?
NASA Astrophysics Data System (ADS)
Takano, Yohei
Dissolved oxygen is a widely observed chemical quantity in the oceans along with temperature and salinity. Changes in the dissolved oxygen have been observed over the world oceans. Observed oxygen in the Ocean Station Papa (OSP, 50°N, 145°W) in the Gulf of Alaska exhibits strong variability over interannual and decadal timescales, however, the mechanisms driving the observed variability are not yet fully understood. Furthermore, irregular sampling frequency and relatively short record length make it difficult to detect a low-frequency variability. Motivated by these observations, we investigate the mechanisms driving the low-frequency variability of oxygen in the subpolar North Pacific. The specific purposes of this study are (1) to evaluate the robustness of the observed low-frequency variability of dissolved oxygen and (2) to determine the mechanisms driving the observed variability using statistical data analysis and numerical simulations. To evaluate the robustness of the low-frequency variability, we conducted spectral analyses on the observed oxygen at OSP. To address the irregular sampling frequency we randomly sub-sampled the raw data to form 500 ensemble members with a regular time interval, and then performed spectral analyses. The resulting power spectrum of oxygen exhibits a robust low-frequency variability and a statistically significant spectral peak is identified at a timescale of 15--20 years. The wintertime oceanic barotropic streamfunction is significantly correlated with the observed oxygen anomaly at OSP with a north-south dipole structure over the North Pacific. We hypothesize that the observed low-frequency variability is primarily driven by the variability of large-scale ocean circulation in the North Pacific. To test this hypothesis, we simulate the three-dimensional distribution of oxygen anomaly between 1952 to 2001 using data-constrained circulation fields. The simulated oxygen anomaly shows an outstanding variability in the Gulf of Alaska, showing that this region is a hotspot of oxygen fluctuation. Anomalous advection acting on the climatological mean oxygen gradient is the source of oxygen variability in this simulation. Empirical Orthogonal Function (EOF) analyses of the simulated oxygen show that the two dominant modes of the oxygen anomaly explains more than 50% of oxygen variance over the North Pacific, that are closely related to the dominant modes of climate variability in the North Pacific (Pacific Decadal Oscillation and North Pacific Oscillation). Our results imply the important link between large-scale climate fluctuations, ocean circulation and biogeochemical tracers in the North Pacific.
NASA Astrophysics Data System (ADS)
Barton, C. C.; Smigelski, J. R.; Tebbens, S. F.
2008-12-01
Most coastal regions are subject to inundation due to many periodic and non-periodic inputs including for example: diurnal and semi diurnal tides, storms, tsunamis, and global sea level change. Tide guage data provide a frequently sampled long term record of fluctuations in water level. A power-spectral-density analysis of tidal gauge data is used to quantify persistence (degree of internal correlation over various time intervals) in terms of the scaling exponent β and to identify temporal changes in persistence. The stations are located at different proximity to the open ocean, including bays, harbors, and channels. The datasets are from the NOAA CO-OPS Verified Hourly Station Datum. The length of the data sets ranges from 3 years to 101 years. The hourly data sets are decimated to one record every four hours. All data sets analyzed show three distinct regions of persistence with two inflection points at approximately one day and five days. For times less than one day, the scaling exponent ranges between 0 < β < 2.6. For the time interval 1 to 5 days, the scaling exponent ranges between 1.1 < β < 2.1. For times greater than 5 days, the scaling exponent ranges between 0.4 < β < 0.9. Persistence generally decreases as period increases but is stable between the inflection points. At Duck, NC, long term persistence in the tide gauge signal is 0.6 as compared to 0.9 for the biweekly shoreline position signal over twenty years, suggesting a strong correlation between the two and the possibility of using tide gauge data to quantify nearby shoreline mobility over similar time intervals.
EPOXI at Earth's Poles: Empirical Test for Observations of an Exoplanet at High Obliquity
NASA Astrophysics Data System (ADS)
Livengood, Timothy A.; A'Hearn, M. F.; Deming, D.; Charbonneau, D.; Barry, R. K.; Hewagama, T.; Lisse, C. M.; McFadden, L.; Meadows, V.; Seager, S.; Wellnitz, D.; EPOXI-EPOCh Science Team
2009-09-01
Observations of the Earth have been obtained by the EPOXI mission to investigate empirically the visible-to-near infrared spectral distribution and lightcurve variations of the Earth as a model for terrestrial exoplanets. Exoplanetary systems may be at arbitrary inclination to the solar system, and may include planets of arbitrary obliquity. The EPOXI mission has previously observed the Earth from within the ecliptic plane and has now acquired measurements at high northern and southern sub-spacecraft latitude with nearly identical phase angle and range. On 27-28 Mar 2009 UT, the whole disc of the Earth was observed from a sub-spacecraft latitude of 62°N at 87° phase angle (53.5% illumination) and 0.114 AU range. On 27 Sep 2009, Earth will have been observed from a sub-spacecraft latitude of 74°S at 87° phase angle (52.7% illumination) and 0.115 AU range. The Earth was near the spring equinox of each pole as it was observed. The visible-light signal was sampled with 7 filters of approximately 100 nm width at 100 nm spacing over 350-950 nm central wavelength, at 15-minute intervals in 4 selected filters and 1-hour intervals in the remaining 3 filters. Near-IR spectroscopy at 1-4.8 µm was obtained at 2-hour intervals. These polar data, capturing the polar ice caps and high latitude climatic regions, will be compared to similar data previously acquired from over the equator, to investigate distinctions in the ability to discern from the global average the spectroscopic signature of vegetation and biogenic gas species. This work is supported by the NASA Discovery Program.
[Estimation of Hunan forest carbon density based on spectral mixture analysis of MODIS data].
Yan, En-ping; Lin, Hui; Wang, Guang-xing; Chen, Zhen-xiong
2015-11-01
With the fast development of remote sensing technology, combining forest inventory sample plot data and remotely sensed images has become a widely used method to map forest carbon density. However, the existence of mixed pixels often impedes the improvement of forest carbon density mapping, especially when low spatial resolution images such as MODIS are used. In this study, MODIS images and national forest inventory sample plot data were used to conduct the study of estimation for forest carbon density. Linear spectral mixture analysis with and without constraint, and nonlinear spectral mixture analysis were compared to derive the fractions of different land use and land cover (LULC) types. Then sequential Gaussian co-simulation algorithm with and without the fraction images from spectral mixture analyses were employed to estimate forest carbon density of Hunan Province. Results showed that 1) Linear spectral mixture analysis with constraint, leading to a mean RMSE of 0.002, more accurately estimated the fractions of LULC types than linear spectral and nonlinear spectral mixture analyses; 2) Integrating spectral mixture analysis model and sequential Gaussian co-simulation algorithm increased the estimation accuracy of forest carbon density to 81.5% from 74.1%, and decreased the RMSE to 5.18 from 7.26; and 3) The mean value of forest carbon density for the province was 30.06 t · hm(-2), ranging from 0.00 to 67.35 t · hm(-2). This implied that the spectral mixture analysis provided a great potential to increase the estimation accuracy of forest carbon density on regional and global level.
Fixed-interval matching-to-sample: intermatching time and intermatching error runs1
Nelson, Thomas D.
1978-01-01
Four pigeons were trained on a matching-to-sample task in which reinforcers followed either the first matching response (fixed interval) or the fifth matching response (tandem fixed-interval fixed-ratio) that occurred 80 seconds or longer after the last reinforcement. Relative frequency distributions of the matching-to-sample responses that concluded intermatching times and runs of mismatches (intermatching error runs) were computed for the final matching responses directly followed by grain access and also for the three matching responses immediately preceding the final match. Comparison of these two distributions showed that the fixed-interval schedule arranged for the preferential reinforcement of matches concluding relatively extended intermatching times and runs of mismatches. Differences in matching accuracy and rate during the fixed interval, compared to the tandem fixed-interval fixed-ratio, suggested that reinforcers following matches concluding various intermatching times and runs of mismatches influenced the rate and accuracy of the last few matches before grain access, but did not control rate and accuracy throughout the entire fixed-interval period. PMID:16812032
NASA Astrophysics Data System (ADS)
Lucas, Michael P.; Emery, Joshua; Pinilla-Alonso, Noemi; Lindsay, Sean S.; MacLennan, Eric M.; Cartwright, Richard; Reddy, Vishnu; Sanchez, Juan A.; Thomas, Cristina A.; Lorenzi, Vania
2017-10-01
Spectral observations of asteroid family members provide valuable information regarding parent body interiors, the source regions of near-Earth asteroids, and the link between meteorites and their parent bodies. Hungaria family asteroids constitute the closest samples to the Earth from a collisional family (~1.94 AU), permitting observations of smaller fragments than accessible for Main Belt families. We have carried out a ground-based observational campaign - Hungaria Asteroid Region Telescopic Spectral Survey (HARTSS) - to record reflectance spectra of these preserved samples from the inner-most primordial asteroid belt. During HARTSS phase one (Lucas et al. [2017]. Icarus 291, 268-287) we found that ~80% of the background population is comprised of stony S-complex asteroids that exhibit considerable spectral and mineralogical diversity. In HARTSS phase two, we turn our attention to family members and hypothesize that the Hungaria collisional family is homogeneous. We test this hypothesis through taxonomic classification, albedo estimates, and spectral properties.During phase two of HARTSS we acquired near-infrared (NIR) spectra of 50 new Hungarias (19 family; 31 background) with SpeX/IRTF and NICS/TNG. We analyzed X-type family spectra for NIR color indices (0.85-J J-K), and a subtle ~0.9 µm absorption feature that may be attributed to Fe-poor orthopyroxene. Surviving fragments of an asteroid collisional family typically exhibit similar taxonomies, albedos, and spectral properties. Spectral analysis of X-type Hungaria family members and independently calculated WISE albedo determinations for 428 Hungaria asteroids is consistent with this scenario. Furthermore, ~1/4 of the background population exhibit similar spectral properties and albedos to family X-types.Spectral observations of 92 Hungaria region asteroids acquired during both phases of HARTSS uncover a compositionally heterogeneous background and spectral homogeneity down to ~2 km for collisional family members. Taxonomy, albedos, and spectral properties reveal that the Hungaria family progenitor was an igneous body that formed under reduced conditions, and was compositionally consistent with the enstatite achondrite (i.e., aubrite) meteorite group.
Kim, Hongbae; Ahn, Saeyoung; Kim, Jungdae; Soh, Kwang-Sup
2008-07-01
We investigated photon emissions of various bio-samples which were induced by ultrasonic stimulation. It has been reported that ultrasonic stimulations induced the thermal excitation of the bio-tissues. After ultrasonic stimulation, any measurement of photon radiation in the visible spectral range has not been carried out yet. The instruments consisted of electronic devices for an ultrasonic generator of the frequency 3 MHz and a photomultiplier tube (PMT) system counting photons from bio-tissues. The transplanted tumor tissues of mice were prepared for the experiments and their liver and spleen tissues were also used for the controls. It was found that the continuous ultrasonic stimulations with the electrical power 2300 mW induced ultraweak photon emissions from the tumor tissues. The number of induced photon was dependent of the type of the tissues and the stimulation time intervals. The level of photon emission was increased from the mouse tumor exposed to the ultrasonic stimulations, and the changes were discriminated from those of the spleens and livers.
Mueller, Daniela; Ferrão, Marco Flôres; Marder, Luciano; da Costa, Adilson Ben; de Cássia de Souza Schneider, Rosana
2013-01-01
The main objective of this study was to use infrared spectroscopy to identify vegetable oils used as raw material for biodiesel production and apply multivariate analysis to the data. Six different vegetable oil sources—canola, cotton, corn, palm, sunflower and soybeans—were used to produce biodiesel batches. The spectra were acquired by Fourier transform infrared spectroscopy using a universal attenuated total reflectance sensor (FTIR-UATR). For the multivariate analysis principal component analysis (PCA), hierarchical cluster analysis (HCA), interval principal component analysis (iPCA) and soft independent modeling of class analogy (SIMCA) were used. The results indicate that is possible to develop a methodology to identify vegetable oils used as raw material in the production of biodiesel by FTIR-UATR applying multivariate analysis. It was also observed that the iPCA found the best spectral range for separation of biodiesel batches using FTIR-UATR data, and with this result, the SIMCA method classified 100% of the soybean biodiesel samples. PMID:23539030
(LMRG): Microscope Resolution, Objective Quality, Spectral Accuracy and Spectral Un-mixing
Bayles, Carol J.; Cole, Richard W.; Eason, Brady; Girard, Anne-Marie; Jinadasa, Tushare; Martin, Karen; McNamara, George; Opansky, Cynthia; Schulz, Katherine; Thibault, Marc; Brown, Claire M.
2012-01-01
The second study by the LMRG focuses on measuring confocal laser scanning microscope (CLSM) resolution, objective lens quality, spectral imaging accuracy and spectral un-mixing. Affordable test samples for each aspect of the study were designed, prepared and sent to 116 labs from 23 countries across the globe. Detailed protocols were designed for the three tests and customized for most of the major confocal instruments being used by the study participants. One protocol developed for measuring resolution and objective quality was recently published in Nature Protocols (Cole, R. W., T. Jinadasa, et al. (2011). Nature Protocols 6(12): 1929–1941). The first study involved 3D imaging of sub-resolution fluorescent microspheres to determine the microscope point spread function. Results of the resolution studies as well as point spread function quality (i.e. objective lens quality) from 140 different objective lenses will be presented. The second study of spectral accuracy looked at the reflection of the laser excitation lines into the spectral detection in order to determine the accuracy of these systems to report back the accurate laser emission wavelengths. Results will be presented from 42 different spectral confocal systems. Finally, samples with double orange beads (orange core and orange coating) were imaged spectrally and the imaging software was used to un-mix fluorescence signals from the two orange dyes. Results from 26 different confocal systems will be summarized. Time will be left to discuss possibilities for the next LMRG study.
Compton thick AGN in Chandra sureys
NASA Astrophysics Data System (ADS)
Brightman, Murray; Nandra, Kirpal
2014-07-01
We present the results from the X-ray spectral analysis of active galactic nuclei (AGN) in the Chandra Deep Field-South, AEGIS-XD and Chandra-COSMOS surveys, focussing on the identification and characterisation of the most heavily obscured, Compton thick (CT, N H > 104 cm-2) sources. Our sample is comprised of 3088 X-ray selected sources, which has a high rate of redshift completeness (97%). The aim is to produce the largest and cleanest uniform sample of these sources from the data as possible. We identify these sources through X-ray spectral fitting, utilising torus spectral models designed for heavily obscured AGN which self consistently include the spectral signatures of heavy absorption, being Compton scattering, photoelectric absorption and iron Kα fluorescence. We identify a total of 163 CT AGN covering an intrinsic 2-10 keV X-ray luminosity range of 102 -3 × 105 erg s-1 and from z = 0.1-7.
Sensitive Spectroscopic Analysis of Biomarkers in Exhaled Breath
NASA Astrophysics Data System (ADS)
Bicer, A.; Bounds, J.; Zhu, F.; Kolomenskii, A. A.; Kaya, N.; Aluauee, E.; Amani, M.; Schuessler, H. A.
2018-06-01
We have developed a novel optical setup which is based on a high finesse cavity and absorption laser spectroscopy in the near-IR spectral region. In pilot experiments, spectrally resolved absorption measurements of biomarkers in exhaled breath, such as methane and acetone, were carried out using cavity ring-down spectroscopy (CRDS). With a 172-cm-long cavity, an efficient optical path of 132 km was achieved. The CRDS technique is well suited for such measurements due to its high sensitivity and good spectral resolution. The detection limits for methane of 8 ppbv and acetone of 2.1 ppbv with spectral sampling of 0.005 cm-1 were achieved, which allowed to analyze multicomponent gas mixtures and to observe absorption peaks of 12CH4 and 13CH4. Further improvements of the technique have the potential to realize diagnostics of health conditions based on a multicomponent analysis of breath samples.
a Novel Deep Convolutional Neural Network for Spectral-Spatial Classification of Hyperspectral Data
NASA Astrophysics Data System (ADS)
Li, N.; Wang, C.; Zhao, H.; Gong, X.; Wang, D.
2018-04-01
Spatial and spectral information are obtained simultaneously by hyperspectral remote sensing. Joint extraction of these information of hyperspectral image is one of most import methods for hyperspectral image classification. In this paper, a novel deep convolutional neural network (CNN) is proposed, which extracts spectral-spatial information of hyperspectral images correctly. The proposed model not only learns sufficient knowledge from the limited number of samples, but also has powerful generalization ability. The proposed framework based on three-dimensional convolution can extract spectral-spatial features of labeled samples effectively. Though CNN has shown its robustness to distortion, it cannot extract features of different scales through the traditional pooling layer that only have one size of pooling window. Hence, spatial pyramid pooling (SPP) is introduced into three-dimensional local convolutional filters for hyperspectral classification. Experimental results with a widely used hyperspectral remote sensing dataset show that the proposed model provides competitive performance.
Terra, Luciana A; Filgueiras, Paulo R; Tose, Lílian V; Romão, Wanderson; de Souza, Douglas D; de Castro, Eustáquio V R; de Oliveira, Mirela S L; Dias, Júlio C M; Poppi, Ronei J
2014-10-07
Negative-ion mode electrospray ionization, ESI(-), with Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) was coupled to a Partial Least Squares (PLS) regression and variable selection methods to estimate the total acid number (TAN) of Brazilian crude oil samples. Generally, ESI(-)-FT-ICR mass spectra present a power of resolution of ca. 500,000 and a mass accuracy less than 1 ppm, producing a data matrix containing over 5700 variables per sample. These variables correspond to heteroatom-containing species detected as deprotonated molecules, [M - H](-) ions, which are identified primarily as naphthenic acids, phenols and carbazole analog species. The TAN values for all samples ranged from 0.06 to 3.61 mg of KOH g(-1). To facilitate the spectral interpretation, three methods of variable selection were studied: variable importance in the projection (VIP), interval partial least squares (iPLS) and elimination of uninformative variables (UVE). The UVE method seems to be more appropriate for selecting important variables, reducing the dimension of the variables to 183 and producing a root mean square error of prediction of 0.32 mg of KOH g(-1). By reducing the size of the data, it was possible to relate the selected variables with their corresponding molecular formulas, thus identifying the main chemical species responsible for the TAN values.
NASA Astrophysics Data System (ADS)
Glazner, Allen F.; Sadler, Peter M.
2016-12-01
The duration of a geologic interval, such as the time over which a given volume of magma accumulated to form a pluton, or the lifespan of a large igneous province, is commonly determined from a relatively small number of geochronologic determinations (e.g., 4-10) within that interval. Such sample sets can underestimate the true length of the interval by a significant amount. For example, the average interval determined from a sample of size n = 5, drawn from a uniform random distribution, will underestimate the true interval by 50%. Even for n = 10, the average sample only captures ˜80% of the interval. If the underlying distribution is known then a correction factor can be determined from theory or Monte Carlo analysis; for a uniform random distribution, this factor is
Can Venus magnetosheath plasma evolve into turbulence?
NASA Astrophysics Data System (ADS)
Dwivedi, Navin; Schmid, Daniel; Narita, Yasuhito; Volwerk, Martin; Delva, Magda; Voros, Zoltan; Zhang, Tielong
2014-05-01
The present work aims to understand turbulence properties in planetary magnetosheath regions to obtain physical insight on the energy transfer from the larger to smaller scales, in spirit of searching for power-law behaviors in the spectra which is an indication of the energy cascade and wave-wave interaction. We perform a statistical analysis of energy spectra using the Venus Express spacecraft data in the Venusian magnetosheath. The fluxgate magnetometer data (VEXMAG) calibrated down to 1 Hz as well as plasma data from the ion mass analyzer (ASPERA) aboard the spacecraft are used in the years 2006-2009. Ten-minute intervals in the magnetosheath are selected, which is typical time length of observations of quasi-stationary fluctuations avoiding multiple boundaries crossings. The magnetic field data are transformed into the mean-field-aligned (MFA) coordinate system with respect to the large-scale magnetic field direction and the energy spectra are evaluated using a Welch algorithm in the frequency range between 0.008 Hz and 0.5 Hz for 105 time intervals. The averaged energy spectra show a power law upto 0.3 Hz with the approximate slope of -1, which is flatter than the Kolmogorov slope, -5/3. A slight hump in the spectra is found in the compressive component near 0.3 Hz, which could possibly be realization of mirror mode in the magnetosheath. A spectral break (sudden change in slope) accompanies the spectral hump at 0.4 Hz, above which the spectral curve becomes steeper. The overall spectral shape is reminiscent of turbulence. The low-frequency part with the slope -1 is interpreted as realization of the energy containing range, while the high-frequency part with the steepening is interpreted either as the beginning of energy cascade mediated by mirror mode or as the dissipation range due to wave-particle resonance processes. The present research work is fully supported by FP7/STORM (313038).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lubin, D.; Cutchin, D.; Conant, W.
Longwave emission by the tropical western Pacific atmosphere has been measured at the ocean surface by a Fourier Transform Infrared (FTIR) spectroradiometer deployed aboard the research vessel John Vickers as part of the Central Equatorial Pacific Experiment. The instrument operated throughout a Pacific Ocean crossing, beginning on 7 March 1993 in Honiara, Solomon Islands, and ending on 29 March 1993 in Los Angeles, and recorded longwave emission spectra under atmospheres associated with sea surface temperatures ranging from 291.0 to 302.8 K. Precipitable water vapor abundances ranged from 1.9 to 5.5 column centimeters. Measured emission spectra (downwelling zenith radiance) covered themore » middled infrared (5-20 {mu}m) with one inverse centimeter spectral resolution. FTIR measurements made under an entirely clear field of view are compared with spectra generated by LOWTRAN 7 and MODTRAN 2, as well as downwelling flux calculated by the NCAR COmmunity Climate Model (CCM-2) radiation code, using radiosonde profiles as input data for these calculations. In the spectral interval 800-1000 cm{sup -1}, these comparisons show a discrepance between FTIR data and MODTRAN 2 having an overall variability of 6-7 mW m{sup -2} sr{sup -1} cm and a concave shape that may be related to the representation of water vapor continuum emission in MODTRAN 2. Another discrepancy appears in the spectral interval 1200-1300 cm{sup -1}, whether MODTRAN 2 appears to overestimate zenith radiance by 5 mW m{sup -2} sr-1 cm. These discrepancies appear consistently; however, they become only slightly larger at the highest water vapor abundances. Because these radiance discrepancies correspond to broadband (500-2000 cm{sup -1}) flux uncertainties of around 3 W m{sup -2}, there appear to be no serious inadequacies with the performance of MODTRAN 2 or LOWTRAN 7 at high atmospheric temperatures and water vapor abundances. 23 refs., 10 figs.« less
NASA Astrophysics Data System (ADS)
Suliali, Nyasha J.; Baricholo, Peter; Neethling, Pieter H.; Rohwer, Erich G.
2017-06-01
A spectral-domain Optical Coherence Tomography (OCT) surface profilometry prototype has been developed for the purpose of surface metrology of optical elements. The prototype consists of a light source, spectral interferometer, sample fixture and software currently running on Microsoft® Windows platforms. In this system, a broadband light emitting diode beam is focused into a Michelson interferometer with a plane mirror as its sample fixture. At the interferometer output, spectral interferograms of broadband sources were measured using a Czerny-Turner mount monochromator with a 2048-element complementary metal oxide semiconductor linear array as the detector. The software performs importation and interpolation of interferometer spectra to pre-condition the data for image computation. One dimensional axial OCT images were computed by Fourier transformation of the measured spectra. A first reflection surface profilometry (FRSP) algorithm was then formulated to perform imaging of step-function-surfaced samples. The algorithm re-constructs two dimensional colour-scaled slice images by concatenation of 21 and 13 axial scans to form a 10 mm and 3.0 mm slice respectively. Measured spectral interferograms, computed interference fringe signals and depth reflectivity profiles were comparable to simulations and correlated to displacements of a single reflector linearly translated about the arm null-mismatch point. Surface profile images of a double-step-function-surfaced sample, embedded with inclination and crack detail were plotted with an axial resolution of 11 μm. The surface shape, defects and misalignment relative to the incident beam were detected to the order of a micron, confirming high resolution of the developed system as compared to electro-mechanical surface profilometry techniques.
Weibull thermodynamics: Subexponential decay in the energy spectrum of cosmic-ray nuclei
NASA Astrophysics Data System (ADS)
Tomaschitz, Roman
2017-10-01
The spectral number density of cosmic-ray nuclei is shown to be a multiply broken power law with subexponential spectral cutoff. To this end, a spectral fit is performed to data sets covering the 1GeV - 1011GeV interval of the all-particle cosmic-ray spectrum. The flux points of the ultra-high energy spectral tail measured with the Telescope Array indicate a Weibull cutoff exp(-(E /(kB T)) σ) and permit a precise determination of the cutoff temperature kB T =(2 . 5 ± 0 . 1) × 1010 GeV and the spectral index σ = 0 . 66 ± 0 . 02. Based on the spectral number density inferred from the least-squares fit, the thermodynamics of this stationary non-equilibrium system, a multi-component mixture of relativistic nuclei, is developed. The derivative of entropy with respect to internal energy defines the effective temperature of the nuclei, S,U = 1 /Teff ,kBTeff ≈ 16 . 1 GeV, and the functional dependence between the cutoff temperature in the Weibull exponential and the effective gas temperature is determined. The equipartition ratio is found to be U /(NkBTeff) ≈ 0 . 30. The isochoric and isobaric heat capacities of the nuclear gas are calculated, as well as the isothermal and adiabatic compressibilities and the isobaric expansion coefficient, and it is shown that this non-equilibrated relativistic gas mixture satisfies the thermodynamic inequalities 0
Rosenfeld, Daniel E.; Nishida, Jun; Yan, Chang; Gengeliczki, Zsolt; Smith, Brian J.; Fayer, Michael D.
2012-01-01
The structural dynamics of thin films consisting of tricarbonyl (1,10-phenanthroline)rhenium chloride (RePhen(CO)3Cl) linked to an alkyl silane monolayer through a triazole linker synthesized on silica-on-calcium-fluoride substrates are investigated using ultrafast infrared (IR) techniques. Ultrafast 2D IR vibrational echo experiments and polarization selective heterodyne detected transient grating (HDTG) measurements, as well as polarization dependent FT-IR and AFM experiments are employed to study the samples. The vibrational echo experiments measure spectral diffusion, while the HDTG experiments measure the vibrational excited state population relaxation and investigate the vibrational transition dipole orientational anisotropy decay. To investigate the anticipated impact of vibrational excitation transfer, which can be caused by the high concentration of RePhen(CO)3Cl in the monolayer, a concentration dependence of the spectral diffusion is measured. To generate a range of concentrations, mixed monolayers consisting of both hydrogen terminated and triazole/RePhen(CO)3Cl terminated alkyl silanes are synthesized. It is found that the measured rate of spectral diffusion is independent of concentration, with all samples showing spectral diffusion of 37 ± 6 ps. To definitively test for vibrational excitation transfer, polarization selective HDTG experiments are conducted. Excitation transfer will cause anisotropy decay. Polarization resolved heterodyne detected transient grating spectroscopy is sensitive to anisotropy decay (depolarization) caused by excitation transfer and molecular reorientation. The HDTG experiments show no evidence of anisotropy decay on the appropriate time scale, demonstrating the absence of excitation transfer the RePhen(CO)3Cl. Therefore the influence of excitation transfer on spectral diffusion is inconsequential in these samples, and the vibrational echo measurements of spectral diffusion report solely on structural dynamics. A small amount of very fast (~2 ps time scale) anisotropy decay is observed. The decay is concentration independent, and is assigned to wobbling-in-a-cone orientational motions of the RePhen(CO)3Cl. Theoretical calculations reported previously for experiments on a single concentration of the same type of sample suggested the presence of some vibrational excitation transfer and excitation transfer induced spectral diffusion. Possible reasons for the experimentally observed lack of excitation transfer in these high concentration samples are discussed. PMID:23259027
Bias Assessment of General Chemistry Analytes using Commutable Samples.
Koerbin, Gus; Tate, Jillian R; Ryan, Julie; Jones, Graham Rd; Sikaris, Ken A; Kanowski, David; Reed, Maxine; Gill, Janice; Koumantakis, George; Yen, Tina; St John, Andrew; Hickman, Peter E; Simpson, Aaron; Graham, Peter
2014-11-01
Harmonisation of reference intervals for routine general chemistry analytes has been a goal for many years. Analytical bias may prevent this harmonisation. To determine if analytical bias is present when comparing methods, the use of commutable samples, or samples that have the same properties as the clinical samples routinely analysed, should be used as reference samples to eliminate the possibility of matrix effect. The use of commutable samples has improved the identification of unacceptable analytical performance in the Netherlands and Spain. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has undertaken a pilot study using commutable samples in an attempt to determine not only country specific reference intervals but to make them comparable between countries. Australia and New Zealand, through the Australasian Association of Clinical Biochemists (AACB), have also undertaken an assessment of analytical bias using commutable samples and determined that of the 27 general chemistry analytes studied, 19 showed sufficiently small between method biases as to not prevent harmonisation of reference intervals. Application of evidence based approaches including the determination of analytical bias using commutable material is necessary when seeking to harmonise reference intervals.
Zaugg, Serge; van der Schaar, Mike; Houégnigan, Ludwig; André, Michel
2013-02-01
The analysis of acoustic data from the ocean is a valuable tool to study free ranging cetaceans and anthropogenic noise. Due to the typically large volume of acquired data, there is a demand for automated analysis techniques. Many cetaceans produce acoustic pulses (echolocation clicks) with a pulse repetition interval (PRI) remaining nearly constant over several pulses. Analyzing these pulse trains is challenging because they are often interleaved. This article presents an algorithm that estimates a pulse's PRI with respect to neighboring pulses. It includes a deinterleaving step that operates via a spectral dissimilarity metric. The sperm whale (SW) produces trains with PRIs between 0.5 and 2 s. As a validation, the algorithm was used for the PRI-based identification of SW click trains with data from the NEMO-ONDE observatory that contained other pulsed sounds, mainly from ship propellers. Separation of files containing SW clicks with a medium and high signal to noise ratio from files containing other pulsed sounds gave an area under the receiver operating characteristic curve value of 0.96. This study demonstrates that PRI can be used for the automated identification of SW clicks and that deinterleaving via spectral dissimilarity contributes to algorithm performance.
NASA Astrophysics Data System (ADS)
Bell, R.; Labovitz, M. L.
1982-07-01
A Barnes field spectral reflectometer which collected information in 373 channels covering the region from 0.4 to 2.5 micrometers was assessed for signal utility. A band was judged unsatisfactory if the probability was 0.1 or greater than its signal to noise ratio was less than eight to one. For each of the bands the probability of a noisy observation was estimated under a binomial assumption from a set of field crop spectra covering an entire growing season. A 95% confidence interval was calculated about each estimate and bands whose lower confidence limits were greater than 0.1 were judged unacceptable. As a result, 283 channels were deemed statistically satisfactory. Excluded channels correspond to portions of the electromagnetic spectrum (EMS) where high atmospheric absorption and filter wheel overlap occur. In addition, the analyses uncovered intervals of unsatisfactory detection capability within the blue, red and far infrared regions of vegetation spectra. From the results of the analysis it was recommended that 90 channels monitored by the instrument under consideration be eliminated from future studies. These channels are tabulated and discussed.
Yamada, M; Mizuta, K; Ito, Y; Furuta, M; Sawai, S; Miyata, H
1999-10-01
A hypothesis has been advanced that the autonomic nervous dysfunction (AND) relates to the development of vertigo in Meniere's disease (MD). We also studied the causal relationship between AND and vertigo in MD. We evaluated autonomic nervous function in 17 patients with MD (five men and 12 women ranging in age from 16 to 70 years) by classifying them by their stages of attack and interval of vertigo and with power spectral analysis (PSA) of heart rate variability. Fourteen healthy volunteers were also tested as controls. At the interval stage, parasympathetic nervous hypofunction and significant depression of sympathetic response due to postural changes from the supine to the standing position were observed in many of those patients. At the attack stage, sympathetic nervous hypofunction was observed in some of the patients. These findings lead us to the conclusion that AND relates to vertigo in MD as a predisposing factor. However, the question of whether AND relates as a trigger or as a consequence of vertigo in MD has not been adequately solved in this study. We will make further studies on circadian variation of autonomic nervous function.
Shao, Limin; Griffiths, Peter R; Leytem, April B
2010-10-01
The automated quantification of three greenhouse gases, ammonia, methane, and nitrous oxide, in the vicinity of a large dairy farm by open-path Fourier transform infrared (OP/FT-IR) spectrometry at intervals of 5 min is demonstrated. Spectral pretreatment, including the automated detection and correction of the effect of interrupting the infrared beam, is by a moving object, and the automated correction for the nonlinear detector response is applied to the measured interferograms. Two ways of obtaining quantitative data from OP/FT-IR data are described. The first, which is installed in a recently acquired commercial OP/FT-IR spectrometer, is based on classical least-squares (CLS) regression, and the second is based on partial least-squares (PLS) regression. It is shown that CLS regression only gives accurate results if the absorption features of the analytes are located in very short spectral intervals where lines due to atmospheric water vapor are absent or very weak; of the three analytes examined, only ammonia fell into this category. On the other hand, PLS regression works allowed what appeared to be accurate results to be obtained for all three analytes.
NASA Technical Reports Server (NTRS)
Bell, R.; Labovitz, M. L.
1982-01-01
A Barnes field spectral reflectometer which collected information in 373 channels covering the region from 0.4 to 2.5 micrometers was assessed for signal utility. A band was judged unsatisfactory if the probability was 0.1 or greater than its signal to noise ratio was less than eight to one. For each of the bands the probability of a noisy observation was estimated under a binomial assumption from a set of field crop spectra covering an entire growing season. A 95% confidence interval was calculated about each estimate and bands whose lower confidence limits were greater than 0.1 were judged unacceptable. As a result, 283 channels were deemed statistically satisfactory. Excluded channels correspond to portions of the electromagnetic spectrum (EMS) where high atmospheric absorption and filter wheel overlap occur. In addition, the analyses uncovered intervals of unsatisfactory detection capability within the blue, red and far infrared regions of vegetation spectra. From the results of the analysis it was recommended that 90 channels monitored by the instrument under consideration be eliminated from future studies. These channels are tabulated and discussed.
Ferrero, Alejandro; Rabal, Ana María; Campos, Joaquín; Pons, Alicia; Hernanz, María Luisa
2012-06-01
A type of representation of the spectral bidirectional reflectance distribution function (BRDF) is proposed that distinctly separates the spectral variable (wavelength) from the geometrical variables (spherical coordinates of the irradiation and viewing directions). Principal components analysis (PCA) is used in order to decompose the spectral BRDF in decorrelated spectral components, and the weight that they have at every geometrical configuration of irradiation/viewing is established. This method was applied to the spectral BRDF measurement of a special effect pigment sample, and four principal components with relevant variance were identified. These four components are enough to reproduce the great diversity of spectral reflectances observed at different geometrical configurations. Since this representation is able to separate spectral and geometrical variables, it facilitates the interpretation of the color variation of special effect pigments coatings versus the geometrical configuration of irradiation/viewing.
Spectral Mapping at Asteroid 101955 Bennu
NASA Astrophysics Data System (ADS)
Clark, Beth Ellen; Hamilton, Victoria E.; Emery, Joshua P.; Hawley, C. Luke; Howell, Ellen S.; Lauretta, Dante; Simon, Amy A.; Christensen, Philip R.; Reuter, Dennis
2017-10-01
The OSIRIS-REx Asteroid Sample Return mission was launched in September 2016. The main science surveys of asteroid 101955 Bennu start in March 2019. Science instruments include a Visible-InfraRed Spectrometer (OVIRS) and a Thermal Emission Spectrometer (OTES) that will produce observations that will be co-registered to the tessellated shape model of Bennu (the fundamental unit of which is a triangular facet). One task of the science team is to synthesize the results in real time during proximity operations to contribute to selection of the sampling site. Hence, we will be focused on quickly producing spectral maps for: (1) mineral abundances; (2) band strengths of minerals and chemicals (including a search for the subtle ~5% absorption feature produced by organics in meteorites); and (3) temperature and thermal inertia values. In sum, we will be producing on the order of ~60 spectral maps of Bennu’s surface composition and thermophysical properties. Due to overlapping surface spots, simulations of our spectral maps show there may be an opportunity to perform spectral super-resolution. We have a large parameter space of choices available in creating spectral maps of Bennu, including: (a) mean facet size (shape model resolution), (b) percentage of overlap between subsequent spot measurements, (c) the number of spectral spots measured per facet, and (d) the mathematical algorithm used to combine the overlapping spots (or bin them on a per-facet basis). Projection effects -- caused by irregular sampling of an irregularly shaped object with circular spectrometer fields-of-view and then mapping these circles onto triangular facets -- can be intense. To prepare for prox ops, we are simulating multiple mineralogical “truth worlds” of Bennu to study the projection effects that result from our planned methods of spectral mapping. This presentation addresses: Can we combine the three planned global surveys of the asteroid (to be obtained at different phase angles) to create a spectral map with higher spatial resolution than the native spectrometer field-of-view in order to increase our confidence in detection of a spatially small occurrence of organics on Bennu?
Potential of FTIR spectroscopy for analysis of tears for diagnosis purposes.
Travo, Adrian; Paya, Clément; Déléris, Gérard; Colin, Joseph; Mortemousque, Bruno; Forfar, Isabelle
2014-04-01
It has been widely reported that the tear film, which is crucially important as a protective barrier of the eye, undergoes biochemical changes as a result of a wide range of ocular pathology. This tends to suggest the possibility of early detection of ocular diseases on the basis of biochemical analysis of tears. However, studies of tears by conventional methods of biomolecular and biochemical analysis are often limited by methodological difficulties. Moreover, such analysis could not be applied in the clinic, where structural and morphological analyses by, mainly, slit-lamp biomicroscopy remains the recommended method. In this study, we assessed, for the first time, the potential of FTIR spectroscopy combined with advanced chemometric processing of spectral data for analysis of raw tears for diagnosis purposes. We first optimized sampling and spectral acquisition (tears collection method, tear sample volume, and preservation of the samples) for accurate spectral measurement. On the basis of the results, we focused our study on the possibility of discriminating tears from normal individuals from those of patients with different ocular pathologies, and showed that the most discriminating spectral range is that corresponding to variations of CH2 and CH3 of lipid aliphatic chains. We also report more subtle discrimination of tears from patients with keratoconus and those from patients with non-specific inflammatory ocular diseases, on the basis of variations in spectral ranges attributed notably to lipid and carbohydrate vibrations. Finally, we also succeeded in distinguishing tears from patients with early-stage and late-stage keratoconus on the basis of spectral features attributed to protein structure. Therefore, this study strongly suggests that FTIR spectral analysis of tears could be developed as a valuable and cost-saving tool for biochemical-based detection of ocular diseases, potentially before the appearance of the first morphological signs of diseases. Combined with supervised modelling methods and with use of a spectral data base acquired for representative patients, such a spectral approach could be a useful addition to current methods of clinical analysis for improvement of patient care.
Reference Intervals of Common Clinical Chemistry Analytes for Adults in Hong Kong.
Lo, Y C; Armbruster, David A
2012-04-01
Defining reference intervals is a major challenge because of the difficulty in recruiting volunteers to participate and testing samples from a significant number of healthy reference individuals. Historical literature citation intervals are often suboptimal because they're be based on obsolete methods and/or only a small number of poorly defined reference samples. Blood donors in Hong Kong gave permission for additional blood to be collected for reference interval testing. The samples were tested for twenty-five routine analytes on the Abbott ARCHITECT clinical chemistry system. Results were analyzed using the Rhoads EP evaluator software program, which is based on the CLSI/IFCC C28-A guideline, and defines the reference interval as the 95% central range. Method specific reference intervals were established for twenty-five common clinical chemistry analytes for a Chinese ethnic population. The intervals were defined for each gender separately and for genders combined. Gender specific or combined gender intervals were adapted as appropriate for each analyte. A large number of healthy, apparently normal blood donors from a local ethnic population were tested to provide current reference intervals for a new clinical chemistry system. Intervals were determined following an accepted international guideline. Laboratories using the same or similar methodologies may adapt these intervals if deemed validated and deemed suitable for their patient population. Laboratories using different methodologies may be able to successfully adapt the intervals for their facilities using the reference interval transference technique based on a method comparison study.
Pigeons' Choices between Fixed-Interval and Random-Interval Schedules: Utility of Variability?
ERIC Educational Resources Information Center
Andrzejewski, Matthew E.; Cardinal, Claudia D.; Field, Douglas P.; Flannery, Barbara A.; Johnson, Michael; Bailey, Kathleen; Hineline, Philip N.
2005-01-01
Pigeons' choosing between fixed-interval and random-interval schedules of reinforcement was investigated in three experiments using a discrete-trial procedure. In all three experiments, the random-interval schedule was generated by sampling a probability distribution at an interval (and in multiples of the interval) equal to that of the…
Yang, Pao-Keng
2012-05-01
We present a noniterative algorithm to reliably reconstruct the spectral reflectance from discrete reflectance values measured by using multicolor light emitting diodes (LEDs) as probing light sources. The proposed algorithm estimates the spectral reflectance by a linear combination of product functions of the detector's responsivity function and the LEDs' line-shape functions. After introducing suitable correction, the resulting spectral reflectance was found to be free from the spectral-broadening effect due to the finite bandwidth of LED. We analyzed the data for a real sample and found that spectral reflectance with enhanced resolution gives a more accurate prediction in the color measurement.
NASA Astrophysics Data System (ADS)
Yang, Pao-Keng
2012-05-01
We present a noniterative algorithm to reliably reconstruct the spectral reflectance from discrete reflectance values measured by using multicolor light emitting diodes (LEDs) as probing light sources. The proposed algorithm estimates the spectral reflectance by a linear combination of product functions of the detector's responsivity function and the LEDs' line-shape functions. After introducing suitable correction, the resulting spectral reflectance was found to be free from the spectral-broadening effect due to the finite bandwidth of LED. We analyzed the data for a real sample and found that spectral reflectance with enhanced resolution gives a more accurate prediction in the color measurement.
Terry, Leann; Kelley, Ken
2012-11-01
Composite measures play an important role in psychology and related disciplines. Composite measures almost always have error. Correspondingly, it is important to understand the reliability of the scores from any particular composite measure. However, the point estimates of the reliability of composite measures are fallible and thus all such point estimates should be accompanied by a confidence interval. When confidence intervals are wide, there is much uncertainty in the population value of the reliability coefficient. Given the importance of reporting confidence intervals for estimates of reliability, coupled with the undesirability of wide confidence intervals, we develop methods that allow researchers to plan sample size in order to obtain narrow confidence intervals for population reliability coefficients. We first discuss composite reliability coefficients and then provide a discussion on confidence interval formation for the corresponding population value. Using the accuracy in parameter estimation approach, we develop two methods to obtain accurate estimates of reliability by planning sample size. The first method provides a way to plan sample size so that the expected confidence interval width for the population reliability coefficient is sufficiently narrow. The second method ensures that the confidence interval width will be sufficiently narrow with some desired degree of assurance (e.g., 99% assurance that the 95% confidence interval for the population reliability coefficient will be less than W units wide). The effectiveness of our methods was verified with Monte Carlo simulation studies. We demonstrate how to easily implement the methods with easy-to-use and freely available software. ©2011 The British Psychological Society.
NASA Astrophysics Data System (ADS)
Lim, Hoong-Ta; Murukeshan, Vadakke Matham
2017-06-01
Hyperspectral imaging combines imaging and spectroscopy to provide detailed spectral information for each spatial point in the image. This gives a three-dimensional spatial-spatial-spectral datacube with hundreds of spectral images. Probe-based hyperspectral imaging systems have been developed so that they can be used in regions where conventional table-top platforms would find it difficult to access. A fiber bundle, which is made up of specially-arranged optical fibers, has recently been developed and integrated with a spectrograph-based hyperspectral imager. This forms a snapshot hyperspectral imaging probe, which is able to form a datacube using the information from each scan. Compared to the other configurations, which require sequential scanning to form a datacube, the snapshot configuration is preferred in real-time applications where motion artifacts and pixel misregistration can be minimized. Principal component analysis is a dimension-reducing technique that can be applied in hyperspectral imaging to convert the spectral information into uncorrelated variables known as principal components. A confidence ellipse can be used to define the region of each class in the principal component feature space and for classification. This paper demonstrates the use of the snapshot hyperspectral imaging probe to acquire data from samples of different colors. The spectral library of each sample was acquired and then analyzed using principal component analysis. Confidence ellipse was then applied to the principal components of each sample and used as the classification criteria. The results show that the applied analysis can be used to perform classification of the spectral data acquired using the snapshot hyperspectral imaging probe.
NASA Astrophysics Data System (ADS)
Urboniene, V.; Velicka, M.; Ceponkus, J.; Pucetaite, M.; Jankevicius, F.; Sablinskas, V.; Steiner, G.
2016-03-01
Determination of cancerous and normal kidney tissues during partial, simple or radical nephrectomy surgery was performed by using differences in the IR absorption spectra of extracellular fluid taken from the corresponding tissue areas. The samples were prepared by stamping of the kidney tissue on ATR diamond crystal. The spectral measurements were performed directly in the OR during surgery for 58 patients. It was found that intensities of characteristic spectral bands of glycogen (880-1200 cm-1) in extracellular fluid are sensitive to the type of the tissue and can be used as spectral markers of tumours. Characteristic spectral band of lactic acid (1730 cm-1) - product of the anaerobic glycolysis, taking place in the cancer cells is not suitable for use as a spectral marker of cancerous tissue, since it overlaps with the band of carbonyl stretch in phospholipids and fatty acids. Results of hierarchical cluster analysis of the spectra show that the spectra of healthy and tumour tissue films can be reliably separated into two groups. On the other hand, possibility to differentiate between tumours of different types and grades remains in question. While the fluid from highly malignant G3 tumour tissue contains highly pronounced glycogen spectral bands and can be well separated from benign and G1 tumours by principal component analysis, the variations between spectra from sample to sample prevent from obtaining conclusive results about the grouping between different tumour types and grades. The proposed method is instant and can be used in situ and even in vivo.
[NIR Assignment of Magnolol by 2D-COS Technology and Model Application Huoxiangzhengqi Oral Liduid].
Pei, Yan-ling; Wu, Zhi-sheng; Shi, Xin-yuan; Pan, Xiao-ning; Peng, Yan-fang; Qiao, Yan-jiang
2015-08-01
Near infrared (NIR) spectroscopy assignment of Magnolol was performed using deuterated chloroform solvent and two-dimensional correlation spectroscopy (2D-COS) technology. According to the synchronous spectra of deuterated chloroform solvent and Magnolol, 1365~1455, 1600~1720, 2000~2181 and 2275~2465 nm were the characteristic absorption of Magnolol. Connected with the structure of Magnolol, 1440 nm was the stretching vibration of phenolic group O-H, 1679 nm was the stretching vibration of aryl and methyl which connected with aryl, 2117, 2304, 2339 and 2370 nm were the combination of the stretching vibration, bending vibration and deformation vibration for aryl C-H, 2445 nm were the bending vibration of methyl which linked with aryl group, these bands attribut to the characteristics of Magnolol. Huoxiangzhengqi Oral Liduid was adopted to study the Magnolol, the characteristic band by spectral assignment and the band by interval Partial Least Squares (iPLS) and Synergy interval Partial Least Squares (SiPLS) were used to establish Partial Least Squares (PLS) quantitative model, the coefficient of determination Rcal(2) and Rpre(2) were greater than 0.99, the Root Mean of Square Error of Calibration (RM-SEC), Root Mean of Square Error of Cross Validation (RMSECV) and Root Mean of Square Error of Prediction (RMSEP) were very small. It indicated that the characteristic band by spectral assignment has the same results with the Chemometrics in PLS model. It provided a reference for NIR spectral assignment of chemical compositions in Chinese Materia Medica, and the band filters of NIR were interpreted.
Very narrow band model calculations of atmospheric fluxes and cooling rates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bernstein, L.S.; Berk, A.; Acharya, P.K.
1996-10-15
A new very narrow band model (VNBM) approach has been developed and incorporated into the MODTRAN atmospheric transmittance-radiance code. The VNBM includes a computational spectral resolution of 1 cm{sup {minus}1}, a single-line Voigt equivalent width formalism that is based on the Rodgers-Williams approximation and accounts for the finite spectral width of the interval, explicit consideration of line tails, a statistical line overlap correction, a new sublayer integration approach that treats the effect of the sublayer temperature gradient on the path radiance, and the Curtis-Godson (CG) approximation for inhomogeneous paths. A modified procedure for determining the line density parameter 1/d ismore » introduced, which reduces its magnitude. This results in a partial correction of the VNBM tendency to overestimate the interval equivalent widths. The standard two parameter CG approximation is used for H{sub 2}O and CO{sub 2}, while the Goody three parameter CG approximation is used for O{sub 3}. Atmospheric flux and cooling rate predictions using a research version of MODTRAN, MODR, are presented for H{sub 2}O (with and without the continuum), CO{sub 2}, and O{sub 3} for several model atmospheres. The effect of doubling the CO{sub 2} concentration is also considered. These calculations are compared to line-by-line (LBL) model calculations using the AER, GLA, GFDL, and GISS codes. The MODR predictions fall within the spread of the LBL results. The effects of decreasing the band model spectral resolution are illustrated using CO{sub 2} cooling rate and flux calculations. 36 refs., 18 figs., 1 tab.« less
Woods, Thomas N; Snow, Martin; Harder, Jerald; Chapman, Gary; Cookson, Angela
A different approach to studying solar spectral irradiance (SSI) variations, without the need for long-term (multi-year) instrument degradation corrections, is examining the total energy of the irradiance variation during 6-month periods. This duration is selected because a solar active region typically appears suddenly and then takes 5 to 7 months to decay and disperse back into the quiet-Sun network. The solar outburst energy, which is defined as the irradiance integrated over the 6-month period and thus includes the energy from all phases of active region evolution, could be considered the primary cause for the irradiance variations. Because solar cycle variation is the consequence of multiple active region outbursts, understanding the energy spectral variation may provide a reasonable estimate of the variations for the 11-year solar activity cycle. The moderate-term (6-month) variations from the Solar Radiation and Climate Experiment (SORCE) instruments can be decomposed into positive (in-phase with solar cycle) and negative (out-of-phase) contributions by modeling the variations using the San Fernando Observatory (SFO) facular excess and sunspot deficit proxies, respectively. These excess and deficit variations are fit over 6-month intervals every 2 months over the mission, and these fitted variations are then integrated over time for the 6-month energy. The dominant component indicates which wavelengths are in-phase and which are out-of-phase with solar activity. The results from this study indicate out-of-phase variations for the 1400 - 1600 nm range, with all other wavelengths having in-phase variations.
Short-term variability of blood pressure and heart rate in hyperthyroidism.
Girard, A; Hugues, F C; Le Jeunne, C; Elghozi, J L
1998-06-01
The effect of hyperthyroidism on the short-term memory variability of blood pressure and heart rate was evaluated in 12 untreated hyperthyroid patients during thyrotoxicosis and after a 6 1/2 month treatment designed to achieve a stable euthyroid state. Beat-by-beat finger blood pressure was measured with a Finapres device. The pulse interval, from which pulse rate was derived, was obtained from the blood pressure signal. Due to the significant change in heart rhythm associated with thyrotoxicosis, both pulse interval (taken as a surrogate of heart period) and pulse rate (taken as a surrogate of heart rate) were computed. Power spectral analysis showed a reduction in the overall heart period variability in the supine position in the hyperthyroid compared to the euthyroid state. This effect was observed in the low-frequency (0.005-0.068 Hz), mid-frequency (0.068-0.127 Hz) and high-frequency (respiratory) domains as well, with a significant reduction of the modulus of these bands of 31%, 35% and 47%, respectively. The heart rate spectral modulus also exhibited a reduction of the high-frequency component (31%) in the supine position in the hyperthyroid subjects. These changes in heart rhythmicity corroborate a vagal deficit in hyperthyroidism. In addition, blood pressure spectral power exhibited a significant deficit in the orthostatism-induced mid-frequency systolic blood pressure rise in the hyperthyroid state (64%) compared with the euthyroid state. This observation may reflect a reduced vascular sympathetic activation with standing. The resulting vasodilatation could well contribute to normalize blood pressure in thyrotoxicosis in which cardiac output is increased.
Multiplex CARS imaging with spectral notch shaped laser pulses delivered by optical fibers.
Oh, Seung Ryeol; Park, Joo Hyun; Kim, Kyung-Soo; Lee, Jae Yong; Kim, Soohyun
2017-12-11
We present an experimental demonstration of single-pulse coherent anti-Stokes Raman spectroscopy (CARS) using a spectrally shaped broadband laser that is delivered by an optical fiber to a sample at its distal end. The optical fiber consists of a fiber Bragg grating component to serve as a narrowband notch filter and a combined large-mode-area fiber to transmit such shaped ultrashort laser pulses without spectral distortion in a long distance. Experimentally, our implementation showed a capability to measure CARS spectra of various samples with molecular vibrations in the fingerprint region. Furthermore, CARS imaging of poly(methyl methacrylate) bead samples was carried out successfully under epi-CARS geometry in which backward-scattered CARS signals were collected into a multimode optical fiber. A compatibility of single-pulse CARS scheme with fiber optics, verified in this study, implies a potential for future realization of compact all-fiber CARS spectroscopic imaging systems.