Sample records for spherical diameter esd

  1. Retrieval of phytoplankton cell size from chlorophyll a specific absorption and scattering spectra of phytoplankton.

    PubMed

    Zhou, Wen; Wang, Guifen; Li, Cai; Xu, Zhantang; Cao, Wenxi; Shen, Fang

    2017-10-20

    Phytoplankton cell size is an important property that affects diverse ecological and biogeochemical processes, and analysis of the absorption and scattering spectra of phytoplankton can provide important information about phytoplankton size. In this study, an inversion method for extracting quantitative phytoplankton cell size data from these spectra was developed. This inversion method requires two inputs: chlorophyll a specific absorption and scattering spectra of phytoplankton. The average equivalent-volume spherical diameter (ESD v ) was calculated as the single size approximation for the log-normal particle size distribution (PSD) of the algal suspension. The performance of this method for retrieving cell size was assessed using the datasets from cultures of 12 phytoplankton species. The estimations of a(λ) and b(λ) for the phytoplankton population using ESD v had mean error values of 5.8%-6.9% and 7.0%-10.6%, respectively, compared to the a(λ) and b(λ) for the phytoplankton populations using the log-normal PSD. The estimated values of C i ESD v were in good agreement with the measurements, with r 2 =0.88 and relative root mean square error (NRMSE)=25.3%, and relatively good performances were also found for the retrieval of ESD v with r 2 =0.78 and NRMSE=23.9%.

  2. Leiomyosarcoma of the stomach treated by endoscopic submucosal dissection.

    PubMed

    Sato, Takao; Akahoshi, Kazuya; Tomoeda, Naru; Kinoshita, Norikatsu; Kubokawa, Masaru; Yodoe, Kentaro; Hiraki, Yuka; Oya, Masafumi; Yamamoto, Hidetaka; Ihara, Eikichi

    2018-03-02

    There have been no reports of primary leiomyosarcoma of the stomach treated by endoscopic submucosal dissection (ESD). We report an extremely rare case of gastric leiomyosarcoma that was successfully treated by ESD. An asymptomatic 74-year-old female underwent esophagogastroduodenoscopy for screening in December 2013. A centrally depressed submucosal tumor 10 mm in diameter was detected at the posterior wall of the upper gastric body. Follow-up esophagogastroduodenoscopy conducted 5 months later showed that the tumor diameter had increased to 15 mm. Endoscopic ultrasound revealed a hypoechoic mass located in the second to the middle of the third layer. Endoscopic ultrasound-guided fine-needle aspiration demonstrated a myogenic tumor. The tumor was completely resected by ESD without complications. Immunohistopathological diagnosis of the resected specimen was gastric leiomyosarcoma derived from the muscularis mucosae, with negative lateral and vertical margins. No local recurrence or metastasis has been detected at 36 months after ESD. This is the first report of gastric leiomyosarcoma treated by ESD in the English language literature.

  3. Usefulness of a multifunctional snare designed for colorectal hybrid endoscopic submucosal dissection (with video).

    PubMed

    Ohata, Ken; Muramoto, Takashi; Minato, Yohei; Chiba, Hideyuki; Sakai, Eiji; Matsuhashi, Nobuyuki

    2018-02-01

    Since colorectal endoscopic submucosal dissection (ESD) remains technically difficult, hybrid ESD was developed as an alternative therapeutic option to achieve en bloc resection of relatively large lesions. In this feasibility study, we evaluated the safety and efficacy of hybrid colorectal ESD using a newly developed multifunctional snare. From June to August 2016, we prospectively enrolled 10 consecutive patients with non-pedunculated intramucosal colorectal tumors 20 - 30 mm in diameter. All of the hybrid ESD steps were performed using the "SOUTEN" snare. The knob-shaped tip attached to the loop top helps to stabilize the needle-knife, making it less likely to slip during circumferential incision and enables partial submucosal dissection. All of the lesions were curatively resected by hybrid ESD, with a short mean procedure time (16.1 ± 4.8 minutes). The mean diameters of the resected specimens and tumors were 30.5 ± 4.9 and 26.0 ± 3.5 mm, respectively. No perforations occurred, while delayed bleeding occurred in 1 patient. In conclusion, hybrid ESD using a multifunctional snare enables easy, safe, and cost-effective resection of relatively large colorectal tumors to be achieved. UMIN000022545.

  4. Treatment of gastric epithelial tumours by endoscopic submucosal dissection using an insulated-tip diathermic knife

    PubMed Central

    Hua, Xu Li; Bo, Qian Jun; Gen, Gu Liu; Fei, Lu; Min, Wang Ya; Ming, Li Yu; Sheng, Lu Hua

    2011-01-01

    BACKGROUND: Endoscopic submucosal dissection (ESD) is a promising technique for the treatment of large, pre- and early malignant gastrointestinal lesions. OBJECTIVE: To assess the rates of en bloc resection, incidence of complications, procedure times and therapeutic outcomes of ESD using an insulated-tip diathermic knife; and to investigate predictors of these outcomes based on the final pathological features of biopsy specimens. METHODS: One hundred twenty patients with endoscopically suspected gastric epithelial tumours who were treated with ESD from January 2006 to December 2009 were evaluated. RESULTS: The mean diameter of the gastric epithelial tumours in the present cohort was 1.88 cm. The mean diameter of the resected specimens was 3.33 cm. The en bloc resection rate was 90% (108 of 120). The median length of the operation was 64.6 min. The bleeding and perforation complication rates were 5.0% (six of 120) and 2.5% (three of 120), respectively. Of 10 gastric tumours initially diagnosed as adenocarcinoma on biopsy, four were found to be low-grade dysplasia and six were found to be high-grade dysplasia after resection and final pathological examination. A total of 112 (93.33%) patients underwent curative treatment, eight patients (6.67%) underwent noncurative treatment with ESD, and two patients (1.67%) experienced local recurrence and subsequently underwent surgery. CONCLUSIONS: ESD is a promising local curative treatment option for gastric epithelial tumours, but still carries the risks of bleeding and/or perforation. Differences in the interpretation of histological results among different pathologists and/or between biopsy specimens before ESD and the en bloc tissue specimens after ESD will result in discrepancies. PMID:21321682

  5. Efficacy of a Novel Narrow Knife with Water Jet Function for Colorectal Endoscopic Submucosal Dissection.

    PubMed

    Yoshida, Naohisa; Toyonaga, Takashi; Murakami, Takaaki; Hirose, Ryohei; Ogiso, Kiyoshi; Inada, Yutaka; Rani, Rafiz Abdul; Naito, Yuji; Kishimoto, Mitsuo; Ohara, Yoshiko; Azuma, Takeshi; Itoh, Yoshito

    2017-01-01

    With respect to the knife's design in colorectal endoscopic submucosal dissection (ESD), diameter, water jet function, and electric power are important because these relate to efficient dissection. In this study, we analyzed a novel, narrow ball tip-typed ESD knife with water jet function (Flush knife BT-S, diameter: 2.2 mm, length: 2000 mm, Fujifilm Co., Tokyo, Japan) compared to a regular diameter knife (Flush knife BT, diameter: 2.6 mm, length: 1800 mm). In laboratory and clinical research, electric power, knife insertion time, vacuum/suction amount with knife in the endoscopic channel, and water jet function were analyzed. We used a knife 2.0 mm long for BT-S and BT knives. The BT-S showed faster mean knife insertion time (sec) and better vacuum amount (ml/min) compared to the BT (insertion time: 16.7 versus 21.6, p < 0.001, vacuum amount: 38.0 versus 14.0, p < 0.01). Additionally, the water jet function of the BT-S was not inferior. In 39 colorectal ESD cases in two institutions, there were mean 4.7 times (range: 1-28) of knife insertion. Suction under knife happened 59% (23/39) and suction of fluid could be done in 100%. Our study showed that the narrow knife allows significantly faster knife insertion, better vacuum function, and effective clinical results.

  6. Efficacy of a Novel Narrow Knife with Water Jet Function for Colorectal Endoscopic Submucosal Dissection

    PubMed Central

    Inada, Yutaka; Rani, Rafiz Abdul; Naito, Yuji; Azuma, Takeshi; Itoh, Yoshito

    2017-01-01

    Backgrounds With respect to the knife's design in colorectal endoscopic submucosal dissection (ESD), diameter, water jet function, and electric power are important because these relate to efficient dissection. In this study, we analyzed a novel, narrow ball tip-typed ESD knife with water jet function (Flush knife BT-S, diameter: 2.2 mm, length: 2000 mm, Fujifilm Co., Tokyo, Japan) compared to a regular diameter knife (Flush knife BT, diameter: 2.6 mm, length: 1800 mm). Methods In laboratory and clinical research, electric power, knife insertion time, vacuum/suction amount with knife in the endoscopic channel, and water jet function were analyzed. We used a knife 2.0 mm long for BT-S and BT knives. Results The BT-S showed faster mean knife insertion time (sec) and better vacuum amount (ml/min) compared to the BT (insertion time: 16.7 versus 21.6, p < 0.001, vacuum amount: 38.0 versus 14.0, p < 0.01). Additionally, the water jet function of the BT-S was not inferior. In 39 colorectal ESD cases in two institutions, there were mean 4.7 times (range: 1–28) of knife insertion. Suction under knife happened 59% (23/39) and suction of fluid could be done in 100%. Conclusions Our study showed that the narrow knife allows significantly faster knife insertion, better vacuum function, and effective clinical results. PMID:29081793

  7. Combining virtual observatory and equivalent source dipole approaches to describe the geomagnetic field with Swarm measurements

    NASA Astrophysics Data System (ADS)

    Saturnino, Diana; Langlais, Benoit; Amit, Hagay; Civet, François; Mandea, Mioara; Beucler, Éric

    2018-03-01

    A detailed description of the main geomagnetic field and of its temporal variations (i.e., the secular variation or SV) is crucial to understanding the geodynamo. Although the SV is known with high accuracy at ground magnetic observatory locations, the globally uneven distribution of the observatories hampers the determination of a detailed global pattern of the SV. Over the past two decades, satellites have provided global surveys of the geomagnetic field which have been used to derive global spherical harmonic (SH) models through some strict data selection schemes to minimise external field contributions. However, discrepancies remain between ground measurements and field predictions by these models; indeed the global models do not reproduce small spatial scales of the field temporal variations. To overcome this problem we propose to directly extract time series of the field and its temporal variation from satellite measurements as it is done at observatory locations. We follow a Virtual Observatory (VO) approach and define a global mesh of VOs at satellite altitude. For each VO and each given time interval we apply an Equivalent Source Dipole (ESD) technique to reduce all measurements to a unique location. Synthetic data are first used to validate the new VO-ESD approach. Then, we apply our scheme to data from the first two years of the Swarm mission. For the first time, a 2.5° resolution global mesh of VO time series is built. The VO-ESD derived time series are locally compared to ground observations as well as to satellite-based model predictions. Our approach is able to describe detailed temporal variations of the field at local scales. The VO-ESD time series are then used to derive global spherical harmonic models. For a simple SH parametrization the model describes well the secular trend of the magnetic field both at satellite altitude and at the surface. As more data will be made available, longer VO-ESD time series can be derived and consequently used to study sharp temporal variation features, such as geomagnetic jerks.

  8. Risk factors for esophageal stenosis after entire circumferential endoscopic submucosal dissection for superficial esophageal squamous cell carcinoma.

    PubMed

    Miwata, Tomohiro; Oka, Shiro; Tanaka, Shinji; Kagemoto, Kenichi; Sanomura, Yoji; Urabe, Yuji; Hiyama, Toru; Chayama, Kazuaki

    2016-09-01

    Endoscopic submucosal dissection (ESD) is used to perform en block resection for esophageal squamous cell carcinoma, but it is strongly associated with postoperative stenosis, especially during entire circumferential resection. This study aimed to clarify the risk factors for refractory postoperative stenosis after entire circumferential esophageal ESD. Nineteen patients who underwent entire circumferential esophageal ESD from February 2006 to December 2013 at Hiroshima University Hospital were divided into two groups: refractory postoperative stenosis [≥6 endoscopic balloon dilation (EBD) procedures, 12 lesions in 12 patients] and non-refractory postoperative stenosis (≤5 EBD procedures, 7 lesions in 7 patients). We retrospectively examined the patient factors (age, sex, alcohol consumption, smoking index, and chemoradiation therapy history), tumor factors (location, macroscopic type, fibrosis, and depth), and treatment factors (mean procedure time, entire circumferential resection diameter, muscle layer damage, and steroid administration method) between the two groups. Muscle layer damage (p = 0.019) and ≥5 cm of longitudinal mucosal defect length after entire circumferential esophageal ESD (p = 0.010) were significant factors associated with the refractory group. Regarding the patient and tumor factors, there were no significant differences between the two groups. Our data suggest that refractory post-ESD stenosis occurs after entire circumferential esophageal ESD with muscle layer damage and ≥5 cm of longitudinal mucosal defect length.

  9. Continuous form-dependent focusing of non-spherical microparticles in a highly diluted suspension with the help of microfluidic spirals

    NASA Astrophysics Data System (ADS)

    Roth, Tanja; Sprenger, Lisa; Odenbach, Stefan; Häfeli, Urs O.

    2018-04-01

    Microfluidic spirals are able to focus non-spherical microparticles in diluted suspension due to the Dean effect. A secondary flow establishes in a curved channel, consisting of two counter-rotating vortices, which transport particles to an equilibrium position near the inner wall of the channel. The relevant size parameter, which is responsible for successful focusing, is the ratio between the particle diameter of a sphere and the hydraulic diameter, which is a characteristic of the microfluidic spiral. A non-spherical particle has not one but several different size parameters. This study investigated the minor and major axes, the equivalent spherical diameter, and the maximal rotational diameter as an equivalent to the spherical diameter. Using a polydimethylsiloxane (PDMS)-based microfluidic device with spirals, experiments were conducted with artificial peanut-shaped and ellipsoidal particles sized between 3 and 9 μm as well as with the bacteria Bacillus subtilis. Our investigations show that the equivalent spherical diameter, the major axis, and the maximal rotational diameter of a non-spherical particle can predict successful focusing. The minor axis is not suitable for this purpose. Non-spherical particles focused when the ratio of their equivalent spherical diameter to the hydraulic diameter of the channel was larger than 0.07. The particles also focused when the ratio between the maximal rotational diameter or the major axis and the hydraulic diameter was larger than 0.01. These results may help us to separate non-spherical biological particles, such as circulating tumor cells or pathogenic bacteria, from blood in future experimental studies.

  10. Colorectal endoscopic submucosal dissection (ESD) in the West - when can satisfactory results be obtained? A single-operator learning curve analysis.

    PubMed

    Spychalski, Michał; Skulimowski, Aleksander; Dziki, Adam; Saito, Yutaka

    2017-12-01

    Up to date we lack a detailed description of the colorectal endoscopic submucosal dissection (ESD) learning curve, that would represent the experience of the Western center. The aim of this study was to define the critical points of the learning curve and to draw up lesions qualification guidelines tailored to the endoscopists experience. We have carried out a single center prospective study. Between June 2013 and December 2016, 228 primary colorectal lesions were managed by ESD procedure. In order to create a learning curve model and to carry out the analysis the cases were divided into six periods, each consisting of 38 cases. The overall en bloc resection rate was 79.39%. The lowest en bloc resection rate (52.36%) was observed in the first period. After completing 76 procedures, the resection rate surged to 86% and it was accompanied by the significant increase in the mean procedure speed of ≥9 cm 2 /h. Lesions localization and diameter had a signification impact on the outcomes. After 76 procedures, en bloc resection rate of 90.9 and 90.67% were achieved for the left side of colon and rectum, respectively. In the right side of colon statistically significant lower resection rate of 67.57% was observed. We have proved that in the setting of the Western center, colorectal ESD can yield excellent results. It seems that the key to the success during the learning period is 'tailoring' lesions qualification guidelines to the experience of the endoscopist, as lesions diameter and localization highly influence the outcomes.

  11. Effect of the nozzle tip’s geometrical shape on electrospray deposition of organic thin films

    NASA Astrophysics Data System (ADS)

    Ueda, Hiroyuki; Takeuchi, Keita; Kikuchi, Akihiko

    2017-04-01

    Electrospray deposition (ESD) is a favorable wet fabrication technique for organic thin films. We investigated the effects of the nozzle tip’s geometrical shape on the spraying properties of an organic solution used for ESD. Five types of cylindrical metal nozzles with zero (flat end) to four protrusions at the tips were prepared for depositing a solution of a small-molecule compound, tris(8-hydroxyquinolinato)aluminum (Alq3) solution. We confirmed that the diameter of the deposited droplets and their size dispersion decreased with an increase in the number of protrusions. The area occupation ratio of small droplets with a diameter smaller than 2 µm increased from 21 to 83% as the number of protrusions was increased from zero to four. The surface roughness root mean square of 60-nm-thick Alq3 films substantially improved from 32.5 to 6.8 nm with increasing number of protrusions.

  12. Paragenesis of multiple platinum-group mineral populations in Shetland ophiolite chromitite: 3D X-ray tomography and in situ Os isotopes

    NASA Astrophysics Data System (ADS)

    Prichard, H. M.; Barnes, Stephen J.; Dale, C. W.; Godel, B.; Fisher, P. C.; Nowell, G. M.

    2017-11-01

    Chromitite from the Harold's Grave locality in the mantle section of the Shetland ophiolite complex is extremely enriched in Ru, Os and Ir, at μg/g concentrations. High-resolution X-ray computed tomography on micro-cores from these chromitites was used to determine the location, size, distribution and morphology of the platinum-group minerals (PGM). There are five generations of PGM in these chromitites. Small (average 5 μm in equivalent sphere diameter, ESD) euhedral laurites, often with Os-Ir alloys, are totally enclosed in the chromite and are likely to have formed first by direct crystallisation from the magma as the chromite crystallised. Also within the chromitite there are clusters of larger (50 μm ESD) aligned elongate crystals of Pt-, Rh-, Ir-, Os- and Ru-bearing PGM that have different orientations in different chromite crystals. These may have formed either by exsolution, or by preferential nucleation of PGMs in boundary layers around particular growing chromite grains. Thirdly there is a generation of large (100 μm ESD) composite Os-Ir-Ru-rich PGM that are all interstitial to the chromite grains and sometimes form in clusters. It is proposed that Os, Ir and Ru in this generation were concentrated in base metal sulfide droplets that were then re-dissolved into a later sulfide-undersaturated magma, leaving PGM interstitial to the chromite grains. Fourthly there is a group of almost spherical large (80 μm ESD) laurites, hosting minor Os-Ir-Ru-rich PGM that form on the edge or enclosed in chromite grains occurring in a sheet crosscutting a chromitite layer. These may be hosted in an annealed late syn- or post magmatic fracture. Finally a few of the PGM have been deformed in localised shear zones through the chromitites. The vast majority of the PGM - including small PGM enclosed within chromite, larger interstitial PGM and elongate aligned PGM - have Os isotope compositions that give Re-depletion model ages approximately equal to the age of the ophiolite at ∼492 Ma. A number of other PGM - not confined to a single textural group - fall to more or less radiogenic values, with four PGM giving anomalously unradiogenic Os corresponding to an older age of ∼1050 Ma. The 187Os/188Os isotopic ratios for PGM from Cliff and Quoys, from the same ophiolite section, are somewhat more radiogenic than those at Harold's Grave. This may be due to a distinct mantle source history or possibly the assimilation of radiogenic crustal Os.

  13. Complications of endoscopic dilation for esophageal stenosis after endoscopic submucosal dissection of superficial esophageal cancer.

    PubMed

    Kishida, Yoshihiro; Kakushima, Naomi; Kawata, Noboru; Tanaka, Masaki; Takizawa, Kohei; Imai, Kenichiro; Hotta, Kinichi; Matsubayashi, Hiroyuki; Ono, Hiroyuki

    2015-10-01

    Endoscopic dilation (ED) is used for the treatment of benign strictures caused by reflux esophagitis or anastomotic stenosis after esophagectomy. Esophageal stenosis is a major complication after endoscopic submucosal dissection (ESD) of large superficial esophageal cancer, but little is known regarding the incidence of complications of ED for stenosis caused by esophageal ESD. This was a retrospective study conducted at a single institution. From September 2002 to December 2012, a total of 1,337 ED procedures were performed for stenosis after esophageal ESD in 121 patients. The incidence of complications of ED and related clinical characteristics were analyzed. The incidence of bleeding was 0.8 % (1/121) per patient and 0.07 % (1/1,337) per procedure. The incidence of perforation was 4.1 % (5/121) per patient and 0.37 % (5/1,337) per procedure. Perforation occurred at a median of third time of ED procedures (range 2-9 procedures) and at a median of 18 days (range 8-29 days) after ESD. There were no significant characteristics correlated to perforation, such as location, circumferential extent, or diameter of mucosal defect after ESD. The total number of ED procedures was significantly larger among perforation cases (37, range 6-57) compared with those without perforation (7, range 1-70) (p = 0.01), and the treatment duration tended to be longer (190 vs. 69 days, respectively). The incidence of bleeding caused by ED for esophageal stenosis after ESD was very low. Relevant risk of perforation should be considered for patients requiring multiple ED procedures.

  14. VO-ESD: a virtual observatory approach to describe the geomagnetic field temporal variations with application to Swarm data

    NASA Astrophysics Data System (ADS)

    Saturnino, Diana; Langlais, Benoit; Amit, Hagay; Mandea, Mioara; Civet, François; Beucler, Éric

    2017-04-01

    A complete description of the main geomagnetic field temporal variation is crucial to understand dynamics in the core. This variation, termed secular variation (SV), is known with high accuracy at ground magnetic observatory locations. However the description of its spatial variability is hampered by the globally uneven distribution of the observatories. For the past two decades a global coverage of the field changes has been allowed by satellites. Their surveys of the geomagnetic field have been used to derive and improve global spherical harmonic (SH) models through some strict data selection schemes to minimise external field contributions. But discrepancies remain between ground measurements and field predictions by these models. Indeed, the global models do not reproduce small spatial scales of the field temporal variations. To overcome this problem we propose a modified Virtual Observatory (VO) approach by defining a globally homogeneous mesh of VOs at satellite altitude. With this approach we directly extract time series of the field and its temporal variation from satellite measurements as it is done at observatory locations. As satellite measurements are acquired at different altitudes a correction for the altitude is needed. Therefore, we apply an Equivalent Source Dipole (ESD) technique for each VO and each given time interval to reduce all measurements to a unique location, leading to time series similar to those available at ground magnetic observatories. Synthetic data is first used to validate the new VO-ESD approach. Then, we apply our scheme to measurements from the Swarm mission. For the first time, a 2.5 degrees resolution global mesh of VO times series is built. The VO-ESD derived time series are locally compared to ground observations as well as to satellite-based model predictions. The approach is able to describe detailed temporal variations of the field at local scales. The VO-ESD time series are also used to derive global SH models. Without regularization these models describe well the secular trend of the magnetic field. The derivation of longer VO-ESD time series, as more data will be made available, will allow the study of field temporal variations features such as geomagnetic jerks.

  15. Real-time monitoring of focused ultrasound blood-brain barrier opening via subharmonic acoustic emission detection: implementation of confocal dual-frequency piezoelectric transducers

    NASA Astrophysics Data System (ADS)

    Tsai, Chih-Hung; Zhang, Jia-Wei; Liao, Yi-Yi; Liu, Hao-Li

    2016-04-01

    Burst-tone focused ultrasound exposure in the presence of microbubbles has been demonstrated to be effective at inducing temporal and local opening of the blood-brain barrier (BBB), which promises significant clinical potential to deliver therapeutic molecules into the central nervous system (CNS). Traditional contrast-enhanced imaging confirmation after focused ultrasound (FUS) exposure serves as a post-operative indicator of the effectiveness of FUS-BBB opening, however, an indicator that can concurrently report the BBB status and BBB-opening effectiveness is required to provide effective feedback to implement this treatment clinically. In this study, we demonstrate the use of subharmonic acoustic emission detection with implementation on a confocal dual-frequency piezoelectric ceramic structure to perform real-time monitoring of FUS-BBB opening. A confocal dual-frequency (0.55 MHz/1.1 MHz) focused ultrasound transducer was designed. The 1.1 MHz spherically-curved ceramic was employed to deliver FUS exposure to induce BBB-opening, whereas the outer-ring 0.55 MHz ceramic was employed to detect the subharmonic acoustic emissions originating from the target position. In stage-1 experiments, we employed spectral analysis and performed an energy spectrum density (ESD) calculation. An optimized 0.55 MHz ESD level change was shown to effectively discriminate the occurrence of BBB-opening. Wideband acoustic emissions received from 0.55 MHz ceramics were also analyzed to evaluate its correlations with erythrocyte extravasations. In stage-2 real-time monitoring experiments, we applied the predetermined ESD change as a detection threshold in PC-controlled algorithm to predict the FUS exposure intra-operatively. In stage-1 experiment, we showed that subharmonic ESD presents distinguishable dynamics between intact BBB and opened BBB, and therefore a threshold ESD change level (5.5 dB) can be identified for BBB-opening prediction. Using this ESD change threshold detection as a surrogate to on/off control the FUS exposure in stage-2 experiments, we demonstrated both excellent sensitivity (92%) and specificity (92.3%) in discriminating BBB-opening occurrence can be obtained in animal treatments, while concurrently achieving a high positive predicted value (95.8%). Wideband ESD was also highly correlated with the occurrence and level of erythrocyte extravasations (r 2  =  0.81). The proposed system configuration and corresponding analysis based on subharmonic acoustic emissions has the potential to be implemented as a real-time feedback control structure for reliable indication of intact FUS-BBB opening for CNS brain drug delivery.

  16. Real-time monitoring of focused ultrasound blood-brain barrier opening via subharmonic acoustic emission detection: implementation of confocal dual-frequency piezoelectric transducers.

    PubMed

    Tsai, Chih-Hung; Zhang, Jia-Wei; Liao, Yi-Yi; Liu, Hao-Li

    2016-04-07

    Burst-tone focused ultrasound exposure in the presence of microbubbles has been demonstrated to be effective at inducing temporal and local opening of the blood-brain barrier (BBB), which promises significant clinical potential to deliver therapeutic molecules into the central nervous system (CNS). Traditional contrast-enhanced imaging confirmation after focused ultrasound (FUS) exposure serves as a post-operative indicator of the effectiveness of FUS-BBB opening, however, an indicator that can concurrently report the BBB status and BBB-opening effectiveness is required to provide effective feedback to implement this treatment clinically. In this study, we demonstrate the use of subharmonic acoustic emission detection with implementation on a confocal dual-frequency piezoelectric ceramic structure to perform real-time monitoring of FUS-BBB opening. A confocal dual-frequency (0.55 MHz/1.1 MHz) focused ultrasound transducer was designed. The 1.1 MHz spherically-curved ceramic was employed to deliver FUS exposure to induce BBB-opening, whereas the outer-ring 0.55 MHz ceramic was employed to detect the subharmonic acoustic emissions originating from the target position. In stage-1 experiments, we employed spectral analysis and performed an energy spectrum density (ESD) calculation. An optimized 0.55 MHz ESD level change was shown to effectively discriminate the occurrence of BBB-opening. Wideband acoustic emissions received from 0.55 MHz ceramics were also analyzed to evaluate its correlations with erythrocyte extravasations. In stage-2 real-time monitoring experiments, we applied the predetermined ESD change as a detection threshold in PC-controlled algorithm to predict the FUS exposure intra-operatively. In stage-1 experiment, we showed that subharmonic ESD presents distinguishable dynamics between intact BBB and opened BBB, and therefore a threshold ESD change level (5.5 dB) can be identified for BBB-opening prediction. Using this ESD change threshold detection as a surrogate to on/off control the FUS exposure in stage-2 experiments, we demonstrated both excellent sensitivity (92%) and specificity (92.3%) in discriminating BBB-opening occurrence can be obtained in animal treatments, while concurrently achieving a high positive predicted value (95.8%). Wideband ESD was also highly correlated with the occurrence and level of erythrocyte extravasations (r (2)  =  0.81). The proposed system configuration and corresponding analysis based on subharmonic acoustic emissions has the potential to be implemented as a real-time feedback control structure for reliable indication of intact FUS-BBB opening for CNS brain drug delivery.

  17. High pressure jet injection of viscous solutions for endoscopic submucosal dissection (ESD): first clinical experience.

    PubMed

    Pioche, Mathieu; Lépilliez, Vincent; Déprez, Pierre; Giovannini, Marc; Caillol, Fabrice; Piessevaux, Hubert; Rivory, Jérôme; Guillaud, Olivier; Ciocîrlan, Mihai; Salmon, Damien; Lienhart, Isabelle; Lafon, Cyril; Saurin, Jean-Christophe; Ponchon, Thierry

    2015-08-01

    Long lasting elevation is a key factor during endoscopic submucosal dissection (ESD) and can be obtained by water jet injection of saline solution or by viscous macromolecular solutions. In a previous animal study, we assessed the Nestis Enki II system to combine jet injection and viscous solutions. In the present work, we used this combination in humans in different sites of the digestive tract. We retrospectively report all of the consecutive ESD procedures performed with jet injection of viscous solutions in four centers. Information was collected about the lesion, the procedure, the histological result, and the outcomes for the patient. In total, 45 resections were completed by six operators: five experts and one beginner with only one previous experience in human ESD. Lesions were located in the esophagus (10), the stomach (11), the duodenum (1), the colon (1) and the rectum (22). Average maximal lesion diameter was 4.8 cm (SD 2.4, range 2 - 11 cm), average lesion surface area was 19.8 cm(2) (SD 17.7, range 2.2 - 72 cm(2)), and average duration of procedure was 79.9 min (SD 50.3 min, range 19 - 225 min). ESD could be conducted while the endoscope was retroflexed at its maximum in 26 cases. Four adverse events were observed: two diminutive perforations and two delayed bleeding occurrences treated conservatively. The R0 resection rate was 91.1 %. The catheter was obstructed in six occurrences of bleeding. Endoscopic submucosal dissection using high pressure injection of viscous macromolecular solutions is safe and effective in different parts of the digestive tract. It does not impede working with the endoscope in the maximal retroflexed position.

  18. Amniotic membrane grafts for the prevention of esophageal stricture after circumferential endoscopic submucosal dissection.

    PubMed

    Barret, Maximilien; Pratico, Carlos Alberto; Camus, Marine; Beuvon, Frédéric; Jarraya, Mohamed; Nicco, Carole; Mangialavori, Luigi; Chaussade, Stanislas; Batteux, Frédéric; Prat, Frédéric

    2014-01-01

    The prevention of esophageal strictures following circumferential mucosal resection remains a major clinical challenge. Human amniotic membrane (AM) is an easily available material, which is widely used in ophthalmology due to its wound healing, anti-inflammatory and anti-fibrotic properties. We studied the effect of AM grafts in the prevention of esophageal stricture after endoscopic submucosal dissection (ESD) in a swine model. In this prospective, randomized controlled trial, 20 swine underwent a 5 cm-long circumferential ESD of the lower esophagus. In the AM Group (n = 10), amniotic membrane grafts were placed on esophageal stents; a subgroup of 5 swine (AM 1 group) was sacrificed on day 14, whereas the other 5 animals (AM 2 group) were kept alive. The esophageal stent (ES) group (n = 5) had ES placement alone after ESD. Another 5 animals served as a control group with only ESD. The prevalence of symptomatic strictures at day 14 was significantly reduced in the AM group and ES groups vs. the control group (33%, 40% and 100%, respectively, p = 0.03); mean esophageal diameter was 5.8±3.6 mm, 6.8±3.3 mm, and 2.6±1.7 mm for AM, ES, and control groups, respectively. Median (range) esophageal fibrosis thickness was 0.87 mm (0.78-1.72), 1.19 mm (0.28-1.95), and 1.65 mm (0.7-1.79) for AM 1, ES, and control groups, respectively. All animals had developed esophageal strictures by day 35. The anti-fibrotic effect of AM on esophageal wound healing after ESD delayed the development of esophageal stricture in our model. However, this benefit was of limited duration in the conditions of our study.

  19. Method for preparing spherical thermoplastic particles of uniform size

    DOEpatents

    Day, J.R.

    1975-11-17

    Spherical particles of thermoplastic material of virtually uniform roundness and diameter are prepared by cutting monofilaments of a selected diameter into rod-like segments of a selected uniform length which are then heated in a viscous liquid to effect the formation of the spherical particles.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Antsiferov, P. S., E-mail: Ants@isan.troitsk.ru; Dorokhin, L. A.

    The influence of the discharge cavity dimensions on the properties of the spherical plasma formed in a fast discharge was studied experimentally. The passage of a current pulse with an amplitude of 30–40 kA and a rise rate of ~10{sup 12} A/s (a fast discharge) through a spherical ceramic (Al{sub 2}O{sub 3}) cavity with an inner diameter of 11 mm filled with argon at a pressure of 80 Pa results in the formation of a 1- to 2-mm-diameter spherical plasma with an electron temperature of several tens of electronvolts and a density of 10{sup 18}–10{sup 19} cm{sup –3}. It ismore » shown that an increase in the inner diameter of the discharge cavity from 11 to 21 mm leads to the fourfold increase in the formation time of the spherical plasma and a decrease in the average ion charge. A decrease in the cavity diameter to 7 mm makes the spherical plasma unstable.« less

  1. A novel technique using high energy synchronous double-wave laser in endoscopic submucosal dissection of patients with superficial esophageal neoplasm.

    PubMed

    Yao, Jun; Li, Jun; Wang, Peng; Liu, Feng; Li, Zhaoshen

    2018-06-08

    BACKGROUND : Endoscopic submucosal dissection (ESD) has been widely used to treat superficial esophageal neoplasms (SENs). Intraoperative bleeding is one of the main concerns that makes ESD in the esophagus more difficult and time consuming with higher complication rates. We introduced a novel laser endoknife system that enabled better intraoperative hemostasis, and preliminarily investigated its feasibility in ESD for patients with SENs.  17 consecutive patients with SENs were prospectively enrolled. The laser endoknife system was used in marking and submucosal dissection. Data on therapeutic outcomes were collected and analyzed.  The median diameter of the lesions was 2.5 cm and of the resected specimens was 3.0 cm. The median procedure time was 48 minutes. Histologic evaluation revealed 15 high grade intraepithelial neoplasias and two squamous cell carcinomas. No intraoperative bleeding occurred during laser cutting and no significant complications occurred postoperatively. Curative R0 resection was achieved in all patients.  Our new laser endoknife system was feasible in the submucosal dissection of SENs and showed great prospects for future application. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Microporous Ti implant compact coated with hydroxyapatite produced by electro-discharge-sintering and electrostatic-spray-deposition.

    PubMed

    Jo, Y J; Kim, Y H; Jo, Y H; Seong, J G; Chang, S Y; Van Tyne, C J; Lee, W H

    2014-11-01

    A single pulse of 1.5 kJ/0.7 g of atomized spherical Ti powder from 300 μF capacitor was applied to produce the porous-surfaced Ti implant compact by electro-discharge-sintering (EDS). A solid core surrounded by porous layer was self-consolidated by a discharge in the middle of the compact in 122 μsec. Average pore size, porosity, and compressive yield strength of EDS Ti compact were estimated to be about 68.2 μm, 25.5%, and 266.4 MPa, respectively. Coatings with hydroxyapatite (HAp) on the Ti compact were conducted by electrostatic-spray-deposition (ESD) method. As-deposited HAp coating was in the form of porous structure and consisted of HAp particles which were uniformly distributed on the Ti porous structure. By heat-treatment at 700 degrees C, HAp particles were agglomerated each other and melted to form a highly smooth and homogeneous HAp thin film consisted of equiaxed nano-scaled grains. Porous-surfaced Ti implant compacts coated with highly crystalline apatite phase were successfully obtained by using the EDS and ESD techniques.

  3. Amniotic Membrane Grafts for the Prevention of Esophageal Stricture after Circumferential Endoscopic Submucosal Dissection

    PubMed Central

    Barret, Maximilien; Pratico, Carlos Alberto; Camus, Marine; Beuvon, Frédéric; Jarraya, Mohamed; Nicco, Carole; Mangialavori, Luigi; Chaussade, Stanislas; Batteux, Frédéric; Prat, Frédéric

    2014-01-01

    Background and Aims The prevention of esophageal strictures following circumferential mucosal resection remains a major clinical challenge. Human amniotic membrane (AM) is an easily available material, which is widely used in ophthalmology due to its wound healing, anti-inflammatory and anti-fibrotic properties. We studied the effect of AM grafts in the prevention of esophageal stricture after endoscopic submucosal dissection (ESD) in a swine model. Animals and Methods In this prospective, randomized controlled trial, 20 swine underwent a 5 cm-long circumferential ESD of the lower esophagus. In the AM Group (n = 10), amniotic membrane grafts were placed on esophageal stents; a subgroup of 5 swine (AM 1 group) was sacrificed on day 14, whereas the other 5 animals (AM 2 group) were kept alive. The esophageal stent (ES) group (n = 5) had ES placement alone after ESD. Another 5 animals served as a control group with only ESD. Results The prevalence of symptomatic strictures at day 14 was significantly reduced in the AM group and ES groups vs. the control group (33%, 40% and 100%, respectively, p = 0.03); mean esophageal diameter was 5.8±3.6 mm, 6.8±3.3 mm, and 2.6±1.7 mm for AM, ES, and control groups, respectively. Median (range) esophageal fibrosis thickness was 0.87 mm (0.78–1.72), 1.19 mm (0.28–1.95), and 1.65 mm (0.7–1.79) for AM 1, ES, and control groups, respectively. All animals had developed esophageal strictures by day 35. Conclusions The anti-fibrotic effect of AM on esophageal wound healing after ESD delayed the development of esophageal stricture in our model. However, this benefit was of limited duration in the conditions of our study. PMID:24992335

  4. Quantitative ultrasound imaging for monitoring in situ high-intensity focused ultrasound exposure.

    PubMed

    Ghoshal, Goutam; Kemmerer, Jeremy P; Karunakaran, Chandra; Abuhabsah, Rami; Miller, Rita J; Sarwate, Sandhya; Oelze, Michael L

    2014-10-01

    Quantitative ultrasound (QUS) imaging is hypothesized to map temperature elevations induced in tissue with high spatial and temporal resolution. To test this hypothesis, QUS techniques were examined to monitor high-intensity focused ultrasound (HIFU) exposure of tissue. In situ experiments were conducted on mammary adenocarcinoma tumors grown in rats and lesions were formed using a HIFU system. A thermocouple was inserted into the tumor to provide estimates of temperature at one location. Backscattered time-domain waveforms from the tissue during exposure were recorded using a clinical ultrasonic imaging system. Backscatter coefficients were estimated using a reference phantom technique. Two parameters were estimated from the backscatter coefficient (effective scatterer diameter (ESD) and effective acoustic concentration (EAC). The changes in the average parameters in the regions corresponding to the HIFU focus over time were correlated to the temperature readings from the thermocouple. The changes in the EAC parameter were consistently correlated to temperature during both heating and cooling of the tumors. The changes in the ESD did not have a consistent trend with temperature. The mean ESD and EAC before exposure were 120 ± 16 μm and 32 ± 3 dB/cm3, respectively, and changed to 144 ± 9 μm and 51 ± 7 dB/cm3, respectively, just before the last HIFU pulse was delivered to the tissue. After the tissue cooled down to 37 °C, the mean ESD and EAC were 126 ± 8 μm and 35 ± 4 dB/cm3, respectively. Peak temperature in the range of 50-60 °C was recorded by a thermocouple placed just behind the tumor. These results suggest that QUS techniques have the potential to be used for non-invasive monitoring of HIFU exposure. © The Author(s) 2014.

  5. Usefulness of underwater endoscopic submucosal dissection in saline solution with a monopolar knife for colorectal tumors (with videos).

    PubMed

    Nagata, Mitsuru

    2018-05-01

    Generally, colorectal endoscopic submucosal dissection (ESD) is performed with a monopolar knife with CO 2 supply from an endoscope. There are few case reports about underwater ESD (UESD) in saline solution with a bipolar knife. The usefulness and safety of UESD in saline solution with a monopolar knife are unclear. The present study aimed to investigate the usefulness and safety of UESD in saline solution with a monopolar knife for colorectal tumors. This retrospective, observational study on UESD for colorectal tumors included 26 colorectal tumors from 24 patients treated with UESD at our department between October 2015 and February 2017. The characteristics of patients, factors associated with ESD difficulty, treatment results, and variations in blood test data before and after UESD were analyzed. En bloc resection was successful in all lesions without any serious adverse events. The median major diameter of the resected specimens was 30 mm (interquartile range [IQR], 28-35) and of the tumor 22.5 mm (IQR, 17.8-25.3). The median procedure time was 60 minutes (IQR, 45-111) and median speed of dissection 10.4 mm 2 /min (IQR, 6.4-12.2). No cases of perforation occurred. Post-ESD bleeding occurred in only 1 case, and endoscopic hemostasis was achieved. There was no case of electrolyte imbalance requiring treatment after UESD. UESD in saline solution with a monopolar knife for colorectal tumors is useful and safe. UESD has potential advantages that should be further assessed. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  6. Bio-sheet graft therapy for artificial gastric ulcer after endoscopic submucosal dissection: an animal feasibility study.

    PubMed

    Kwon, Chang-Il; Kim, Gwangil; Ko, Kwang Hyun; Jung, Yunho; Chung, Il-Kwun; Jeong, Seok; Lee, Don Haeng; Hong, Sung Pyo; Hahm, Ki Baik

    2015-04-01

    Various bio-sheet grafts have been attempted either to accelerate healing of artificial ulcers or to prevent adverse events after endoscopic submucosal dissection (ESD), but neither prospective nor mechanistic studies were available. To evaluate the substantial effect of a bio-sheet graft on artificial ulcer healing and its feasibility as an endoscopic treatment modality. Preclinical, in vivo animal experiment and proof-of-concept study. Animal laboratory. Three mini-pigs, Sus scrofa, mean age 14 months. Multiple ulcers sized 2.5 cm in diameter were generated by ESD in 3 mini-pigs and were assigned randomly into the following 3 groups; control group, bio-sheet group, or combination (bio-sheet plus drug) group. Bio-sheet grafts or bio-sheet plus drug combinations were applied on the artificial ulcers immediately after the ESD. Feasibility and efficacy of endoscopic bio-sheet graft therapy for the management of artificial ulcers and the evaluation of healing conditions based on histology changes in the remaining gastric bed tissues harvested from the stomachs. Thirty-three ESD specimens were obtained. On an image analysis of the ratio of healed area in the remaining gastric bed tissue compared with the matched dissected gastric mucosa, the control group showed the most significant improvement in healing activity among the 3 groups (P < .05), whereas the severity of inflammation in the remaining ulcer tissue was significantly attenuated in bio-sheet and combination groups (P < .05). Animal model. Although the bio-sheet grafts provided physical protection from gastric acid attack as reflected in the attenuated inflammation on the ulcer beds, unexpected delayed ulcer healing was noted in the bio-sheet graft group because of its physical hindrance of the healing process. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  7. The low incidence of bacteremia after esophageal endoscopic submucosal dissection (ESD) obviates the need for prophylactic antibiotics in esophageal ESD.

    PubMed

    Kawata, Noboru; Tanaka, Masaki; Kakushima, Naomi; Takizawa, Kohei; Imai, Kenichiro; Hotta, Kinichi; Matsubayashi, Hiroyuki; Tsukahara, Mika; Kawamura, Ichiro; Kurai, Hanako; Ono, Hiroyuki

    2016-11-01

    Although a high incidence of bacteremia after esophageal endoscopic procedures has been reported, the incidence of bacteremia associated with esophageal endoscopic submucosal dissection (ESD) remains unknown. Therefore, we investigated the incidence of bacteremia associated with esophageal ESD. From April 2013 to March 2014, patients who underwent esophageal ESD were enrolled prospectively. Two sets of blood cultures were collected from patients at the following time points: (1) immediately after ESD; (2) the next morning; and (3) when fever ≥38 °C was present after ESD. A total of 424 blood culture sets were collected from 101 patients. Six patients had positive blood cultures immediately after ESD (4 %, 7/202 sets). Another patient had a positive blood culture the next morning (0.5 %, 1/202 sets). Ten patients (10 %) developed a post-ESD fever ≥38 °C, and blood cultures from these patients were all negative (0/20 sets). The seven patients with positive blood cultures had no post-ESD fever or infectious symptoms. Growth of Bacteroides thetaiotaomicron was only observed in one patient (1 %) with positive blood cultures immediately after ESD, and this patient was diagnosed with transient bacteremia. The other six patients were considered to have contaminants in their blood cultures. Thus, the incidence of bacteremia after esophageal ESD was 1 % [95 % confidence interval (CI) 0-5 %]. No patient had infectious symptoms, and none required antibiotics after ESD. The incidence of bacteremia after esophageal ESD was low and post-ESD fever was not associated with bacteremia. We conclude that use of routine prophylactic antibiotics to patients undergoing esophageal ESD is unnecessary. UMIN000012908.

  8. Advantages of Environmental Scanning Electron Microscopy in Studies of Microorganisms

    DTIC Science & Technology

    1993-01-01

    external structures, cultures of Aspergillus sp. and Cunninghamella sp. but details of cytoplasmic organization were lacking were maintained on corn meal ... agar . (Fig. 7). Uncoated, freeze-dried Euglena sp. cells exam- ined with either ESD or BSE detectors did not exhibit Specimen Preparation for ESEM...approximately Agar plugs from sporulating cultures of Cunning- 1.0 pLm in diameter (Fig. 23). Many of the vesicles ap- hamella sp., Mucor sp., and Aspergillus

  9. Identifying Key Elements of Community-Based ESD: ESD-J's Projects to Collect ESD in Practice in Japan and Asia

    ERIC Educational Resources Information Center

    Noguchi, Fumiko

    2010-01-01

    Since its establishment in 2003, the Japan Council on the UN Decade of Education for Sustainable Development (ESD-J) has paid close attention to informal learning processes in community-based efforts to promote local sustainable development. ESD-J carried out two projects to collect information on and visualise community-based ESD practice: the…

  10. Hierarchical and hybrid energy storage devices in data centers: Architecture, control and provisioning.

    PubMed

    Sun, Mengshu; Xue, Yuankun; Bogdan, Paul; Tang, Jian; Wang, Yanzhi; Lin, Xue

    2018-01-01

    Recently, a new approach has been introduced that leverages and over-provisions energy storage devices (ESDs) in data centers for performing power capping and facilitating capex/opex reductions, without performance overhead. To fully realize the potential benefits of the hierarchical ESD structure, we propose a comprehensive design, control, and provisioning framework including (i) designing power delivery architecture supporting hierarchical ESD structure and hybrid ESDs for some levels, as well as (ii) control and provisioning of the hierarchical ESD structure including run-time ESD charging/discharging control and design-time determination of ESD types, homogeneous/hybrid options, ESD provisioning at each level. Experiments have been conducted using real Google data center workloads based on realistic data center specifications.

  11. Hierarchical and hybrid energy storage devices in data centers: Architecture, control and provisioning

    PubMed Central

    Xue, Yuankun; Bogdan, Paul; Tang, Jian; Wang, Yanzhi; Lin, Xue

    2018-01-01

    Recently, a new approach has been introduced that leverages and over-provisions energy storage devices (ESDs) in data centers for performing power capping and facilitating capex/opex reductions, without performance overhead. To fully realize the potential benefits of the hierarchical ESD structure, we propose a comprehensive design, control, and provisioning framework including (i) designing power delivery architecture supporting hierarchical ESD structure and hybrid ESDs for some levels, as well as (ii) control and provisioning of the hierarchical ESD structure including run-time ESD charging/discharging control and design-time determination of ESD types, homogeneous/hybrid options, ESD provisioning at each level. Experiments have been conducted using real Google data center workloads based on realistic data center specifications. PMID:29351553

  12. Electrospark Deposition for the Repair of Army Main Battle Tank Components

    DTIC Science & Technology

    2006-07-01

    Inconel 718, and Inconel 625 were deposited onto low-alloy carbon steel and Inconel 718 substrates. 6.2 ESD Procedure Development (M1A1... Inconel 625 Inconel 718 Inconel 718 Inconel 718 Electrode diameter (in) 0.125 0.125 0.125 .125 0.125 0.125 Pulse rate (Hz) 400 400 400 400 400 400...coating Chrome plating Chrome plating Chrome plating Chrome plating Chrome plating Chrome plating Electrode alloy Inconel 718 Inconel

  13. Splash M-knife versus Flush Knife BT in the technical outcomes of endoscopic submucosal dissection for early gastric cancer: a propensity score matching analysis.

    PubMed

    Esaki, Mitsuru; Suzuki, Sho; Hayashi, Yasuyo; Yokoyama, Azusa; Abe, Shuichi; Hosokawa, Taizo; Ogino, Haruei; Akiho, Hirotada; Ihara, Eikichi; Ogawa, Yoshihiro

    2018-02-27

    Endoscopic submucosal dissection (ESD) is a standard treatment for early gastric cancer. A new multi-functional ESD device was developed to achieve complete ESD with a single device. A metal plate attached to its distal sheath achieves better hemostasis during the procedure than the other needle-knife device, Flush Knife BT®, that has been conventionally used. The aim of this study was to compare the technical outcomes of ESD for early gastric cancer using the Splash M-Knife® with those using the Flush Knife BT. We conducted a retrospective review of the case records of 149 patients with early gastric cancer treated with ESD using the needle-type ESD knives between January 2012 and August 2016 at Kitakyushu Municipal Medical Center. Lesions treated with ESD using the Splash M-knife (ESD-M) and the Flush Knife BT (ESD-F) were compared. Multivariate analyses and propensity score matching were used to compensate for the differences in age, gender, underlying disease, antithrombotic drug use, lesion location, lesion position, macroscopic type, tumor size, presence of ulceration, operator level and types of electrosurgical unit used. The primary endpoint was the requirement to use hemostatic forceps in the two groups. The secondary endpoints of procedure time, en bloc and complete resection rates, and adverse events rates were evaluated for the two groups. There were 73 patients in the ESD-M group, and 76 patients in the ESD-F group. Propensity score matching analysis created 45 matched pairs. Adjusted comparisons between the two groups showed a significantly lower usage rate of hemostatic forceps in the ESD-M group than in the ESD-F group (6.7% vs 84.4%, p < 0.001). Treatment outcomes showed an en bloc resection rate of 100% in both groups; complete resection rate of 95.6% vs 100%, p = 0.49; median procedure time of 74.0 min vs 71.0 min, p = 0.90; post-procedure bleeding of 2.2% vs 2.2%, p = 1, in the ESD-M and ESD-F groups, respectively. There were no perforations in either group. ESD-M appeared to reduce the usage of hemostatic forceps during ESD for early gastric cancer without increasing the adverse effects. Thus, it may contribute to a reduction in the total ESD cost.

  14. Conventional versus traction-assisted endoscopic submucosal dissection for gastric neoplasms: a multicenter, randomized controlled trial (with video).

    PubMed

    Yoshida, Masao; Takizawa, Kohei; Suzuki, Sho; Koike, Yoshiki; Nonaka, Satoru; Yamasaki, Yasushi; Minagawa, Takeyoshi; Sato, Chiko; Takeuchi, Chihiro; Watanabe, Ko; Kanzaki, Hiromitsu; Morimoto, Hiroyuki; Yano, Takafumi; Sudo, Kosuke; Mori, Keita; Gotoda, Takuji; Ono, Hiroyuki

    2018-05-01

    The aim of this study was to clarify whether dental floss clip (DFC) traction improves the technical outcomes of endoscopic submucosal dissection (ESD). A superiority, randomized control trial was conducted at 14 institutions across Japan. Patients with single gastric neoplasm meeting the indications of the Japanese guidelines for gastric treatment were enrolled and assigned to receive conventional ESD or DFC traction-assisted ESD (DFC-ESD). Randomization was performed according to a computer-generated random sequence with stratification by institution, tumor location, tumor size, and operator experience. The primary endpoint was ESD procedure time, defined as the time from the start of the submucosal injection to the end of the tumor removal procedure. Between July 2015 and September 2016, 640 patients underwent randomization. Of these, 316 patients who underwent conventional ESD and 319 patients who underwent DFC-ESD were included in our analysis. The mean ESD procedure time was 60.7 and 58.1 minutes for conventional ESD and DFC-ESD, respectively (P = .45). Perforation was less frequent in the DFC-ESD group (2.2% vs .3%, P = .04). For lesions located in the greater curvature of the upper or middle stomach, the mean procedure time was significantly shorter in the DFC-ESD group (104.1 vs 57.2 minutes, P = .01). Our findings suggest that DFC-ESD does not result in shorter procedure time in the overall patient population, but it can reduce the risk of perforation. When selectively applied to lesions located in the greater curvature of the upper or middle stomach, DFC-ESD provides a remarkable reduction in procedure time. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  15. Experimental study of hybrid-knife endoscopic submucosal dissection (ESD) versus standard ESD in a Western country.

    PubMed

    De-la-Peña, Joaquín; Calderón, Ángel; Esteban, José Miguel; López-Rosés, Leopoldo; Martínez-Ares, David; Nogales, Óscar; Orive-Calzada, Aitor; Rodríguez, Sarbelio; Sánchez-Hernández, Eloy; Vila, Juan; Fernández-Esparrach, Gloria

    2014-02-01

    Endoscopic submucosal dissection (ESD) is an effective but time-consuming treatment for early neoplasia that requires a high level of expertise. The objective of this study was to assess the efficacy and learning curve of gastric ESD with a hybrid knife with high pressure water jet and to compare with standard ESD. We performed a prospective non survival animal study comparing hybrid-knife and standard gastric ESD. Variables recorded were: Number of en-bloc ESD, number of ESD with all marks included (R0), size of specimens, time and speed of dissection and adverse events. Ten endoscopists performed a total of 50 gastric ESD (30 hybrid-knife and 20 standard). Forty-six (92 %) ESD were en-bloc and 25 (50 %) R0 (hybrid-knife: n = 13, 44 %; standard: n = 16, 80 %; p = 0.04). Hybrid-knife ESD was faster than standard (time: 44.6 +/- 21.4 minutes vs. 68.7 +/- 33.5 minutes; p = 0.009 and velocity: 20.8 +/- 9.2 mm(2)/min vs. 14.3 +/- 9.3 mm(2)/min (p = 0.079). Adverse events were not different. There was no change in speed with any of two techniques (hybrid-knife: From 20.33 +/- 15.68 to 28.18 +/- 20.07 mm(2)/min; p = 0.615 and standard: From 6.4 +/- 0.3 to 19.48 +/- 19.21 mm(2)/min; p = 0.607). The learning curve showed a significant improvement in R0 rate in the hybrid-knife group (from 30 % to 100 %). despite the initial performance of hybrid-knife ESD is worse than standard ESD, the learning curve with hybrid knife ESD is short and is associated with a rapid improvement. The introduction of new tools to facilitate ESD should be implemented with caution in order to avoid a negative impact on the results.

  16. Zonal Flow Velocimetry in Spherical Couette Flow using Acoustic Modes

    NASA Astrophysics Data System (ADS)

    Adams, Matthew M.; Mautino, Anthony R.; Stone, Douglas R.; Triana, Santiago A.; Lekic, Vedran; Lathrop, Daniel P.

    2015-11-01

    We present studies of spherical Couette flows using the technique of acoustic mode Doppler velocimetry. This technique uses rotational splittings of acoustic modes to infer the azimuthal velocity profile of a rotating flow, and is of special interest in experiments where direct flow visualization is impractical. The primary experimental system consists of a 60 cm diameter outer spherical shell concentric with a 20 cm diameter sphere, with air or nitrogen gas serving as the working fluid. The geometry of the system approximates that of the Earth's core, making these studies geophysically relevant. A turbulent shear flow is established in the system by rotating the inner sphere and outer shell at different rates. Acoustic modes of the fluid volume are excited using a speaker and measured via microphones, allowingdetermination of rotational splittings. Preliminary results comparing observed splittings with those predicted by theory are presented. While the majority of these studies were performed in the 60 cm diameter device using nitrogen gas, some work has also been done looking at acoustic modes in the 3 m diameter liquid sodium spherical Couette experiment. Prospects for measuring zonal velocity profiles in a wide variety of experiments are discussed.

  17. Purification and substrate specificity of polymorphic forms of esterase D from human erythrocytes.

    PubMed Central

    Scott, E M; Wright, R C

    1978-01-01

    Esterase D (EsD), purified from human erythrocytes and tested with a variety of substrates, hydrolyzed only triacetin, tributyrin, and certain soluble aryl esters of aliphatic acids. Esters of 4-methylumbelliferone were easily the best substrates. When the three genetically different isozymes were compared, the less common forms, EsD 2 and EsD 2-1, were less stable than EsD 1. With some substrates, the Michaelis constant of the EsD 2 form differed from that of the EsD 1 form. The EsD 2-1 hybrid form was usually, but not invariably, intermediate in properties. The physiologic significance of the genetic variability of this enzyme is unknown. PMID:623100

  18. How to establish endoscopic submucosal dissection in Western countries.

    PubMed

    Oyama, Tsuneo; Yahagi, Naohisa; Ponchon, Thierry; Kiesslich, Tobias; Berr, Frieder

    2015-10-28

    Endoscopic submucosal dissection (ESD) has been invented in Japan to provide resection for cure of early cancer in the gastrointestinal tract. Professional level of ESD requires excellent staging of early neoplasias with image enhanced endoscopy (IEE) to make correct indications for ESD, and high skills in endoscopic electrosurgical dissection. In Japan, endodiagnostic and endosurgical excellence spread through personal tutoring of skilled endoscopists by the inventors and experts in IEE and ESD. To translocate this expertise to other continents must overcome two fundamental obstacles: (1) inadequate expectations as to the complexity of IEE and ESD; and (2) lack of suitable lesions and master-mentors for ESD trainees. Leading endoscopic mucosal resection-proficient endoscopists must pioneer themselves through the long learning curve to proficient ESD experts. Major referral centers for ESD must arise in Western countries on comparable professional level as in Japan. In the second stage, the upcoming Western experts must commit themselves to teach skilled endoscopists from other referral centers, in order to spread ESD in Western countries. Respect for patients with early gastrointestinal cancer asks for best efforts to learn endoscopic categorization of early neoplasias and skills for ESD based on sustained cooperation with the masters in Japan. The strategy is discussed here.

  19. Usefulness of a traction method using dental floss and a hemoclip for gastric endoscopic submucosal dissection: a propensity score matching analysis (with videos).

    PubMed

    Suzuki, Sho; Gotoda, Takuji; Kobayashi, Yoshiyuki; Kono, Shin; Iwatsuka, Kunio; Yagi-Kuwata, Naoko; Kusano, Chika; Fukuzawa, Masakatsu; Moriyasu, Fuminori

    2016-02-01

    Although endoscopic submucosal dissection (ESD) is a significant advancement in therapeutic endoscopy, it is a complicated technique and requires considerable expertise. In this exploratory study, we evaluated the efficacy of a simple traction method that uses dental floss and a hemoclip (DFC) and was developed to overcome the technical difficulties of ESD. In total, 238 early gastric cancers treated by ESD between May 2012 and December 2014 at Tokyo Medical University were retrospectively reviewed. Lesions treated by conventional ESD (n = 185) and by ESD with DFC (ESD-DFC) (n = 53) were compared. Multivariable analyses and propensity score matching were used to compensate for the differences in age, sex, resected specimen size, lesion location, lesion position, presence of ulceration, and operator level. The procedure time, rate of en bloc and complete resection, and rates of adverse events were evaluated between the 2 groups. Propensity score matching analysis created 43 matched pairs. Adjusted comparisons between ESD-DFC and conventional ESD showed similar treatment outcomes (en bloc resection rate: 97.7% vs 100%, P = .315; complete resection rate: 90.7% vs 95.3%, P = .397; perforation during ESD rate: 2.3% vs 2.3%, P = 1.000; post-ESD bleeding rate: 4.7% vs 4.7%, P = 1.000) but a significantly shorter procedure time for ESD-DFC (82.2 ± 79.5 minutes vs 118.2 ± 71.6 minutes, P = .002). ESD-DFC facilitated rapid ESD with good visualization and traction while ensuring high curability and safety. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  20. Accessory Devices Frequently Used for Endoscopic Submucosal Dissection

    PubMed Central

    Choi, Hyuk Soon; Chun, Hoon Jai

    2017-01-01

    Endoscopic submucosal dissection (ESD) is increasingly being considered an essential component of treatment for early gastrointestinal cancers and subepithelial tumors. The ESD technique owes its popularity to the development of sophisticated instruments used for ESD. With an increase in the number of ESD procedures performed, there is rapid development in the number and types of endoscopic accessory devices used for such procedures. Despite the large numbers of new devices developed and marketed, the use of ESD instruments and accessory devices is largely determined by individual preferences and experiences. Accessory devices frequently used during ESD are important tools for ESD techniques. Each instrument possesses characteristic advantages and disadvantages associated with its use, and no one instrument is superior in all respects to others. In this article, we review the characteristics of endoscopic electrical knives, cap and hood, and hemostatic devices commonly used in ESD. PMID:28609818

  1. Consulting the UK ESD Community on an ESD Indicator to Recommend to Government: An Insight into the Micro-Politics of ESD

    ERIC Educational Resources Information Center

    Huckle, John

    2009-01-01

    In 2006 the author was contracted to research possible approaches to a UK indicator of education for sustainable development (ESD). This article describes and seeks to explain the response of government advisers and influential members of the UK ESD community to the approaches he proposed. While the UK strategy for sustainable development called…

  2. ESD protection design for advanced CMOS

    NASA Astrophysics Data System (ADS)

    Huang, Jin B.; Wang, Gewen

    2001-10-01

    ESD effects in integrated circuits have become a major concern as today's technologies shrink to sub-micron/deep- sub-micron dimensions. The thinner gate oxide and shallower junction depth used in the advanced technologies make them very vulnerable to ESD damages. The advanced techniques like silicidation and STI (shallow trench insulation) used for improving other device performances make ESD design even more challenging. For non-silicided technologies, a certain DCGS (drain contact to gate edge spacing) is needed to achieve ESD hardness for nMOS output drivers and nMOS protection transistors. The typical DCGS values are 4-5um and 2-3um for 0.5um and 0.25um CMOS, respectively. The silicidation reduces the ballast resistance provided by DCGS with at least a factor of 10. As a result, scaling of the ESD performance with device width is lost and even zero ESD performance is reported for standard silicided devices. The device level ESD design is focused in this paper, which includes GGNMOS (gate grounded NMOS) and GCNMOS (gate coupled NMOS). The device level ESD testing including TLP (transmission line pulse) is given. Several ESD issues caused by advanced technologies have been pointed out. The possible solutions have been developed and summarized including silicide blocking, process optimization, back-end ballasting, and new protection scheme, dummy gate/n-well resistor ballsting, etc. Some of them require process cost increase, and others provide novel, compact, and simple design but involving royalty/IP (intellectual property) issue. Circuit level ESD design and layout design considerations are covered. The top-level ESD protection strategies are also given.

  3. Endoscopic therapy for early gastric cancer: Standard techniques and recent advances in ESD

    PubMed Central

    Kume, Keiichiro

    2014-01-01

    The technique of endoscopic submucosal dissection (ESD) is now a well-known endoscopic therapy for early gastric cancer. ESD was introduced to resect large specimens of early gastric cancer in a single piece. ESD can provide precision of histologic diagnosis and can also reduce the recurrence rate. However, the drawback of ESD is its technical difficulty, and, consequently, it is associated with a high rate of complications, the need for advanced endoscopic techniques, and a lengthy procedure time. Various advances in the devices and techniques used for ESD have contributed to overcoming these drawbacks. PMID:24914364

  4. Fabricated autologous epidermal cell sheets for the prevention of esophageal stricture after circumferential ESD in a porcine model.

    PubMed

    Kanai, Nobuo; Yamato, Masayuki; Ohki, Takeshi; Yamamoto, Masakazu; Okano, Teruo

    2012-10-01

    Endoscopic submucosal dissection (ESD) is an accepted treatment for early esophageal carcinoma. However, resection of a large mucosal area, as with circumferential ESD, induces severe stricture formation. To evaluate the efficacy of cultured autologous epidermal cell sheets to prevent severe esophageal constriction after circumferential ESD. Animal study. University institute. Eight pigs underwent circumferential esophageal ESD while under general anesthesia. In 4 pigs, fabricated autologous epidermal cell sheets were endoscopically transplanted to the central ESD sites immediately after the ESD. The other 4 pigs underwent circumferential ESD only. Necropsy and histological assessment were performed at 1 and 2 weeks post-ESD. Weight gain, degree of mucosal constriction, and histological assessments. All pigs in the control group showed severe esophageal constriction after 2 weeks. The control and transplanted groups had weight gains of -10.3% and 0.3% (P = .03), respectively, and the mean degrees of constriction were 88% and 56% (P < .01), respectively. Early re-epithelialization and mild fibrosis in the muscularis were observed in the transplanted group. Animal study, small sample size. Fabricated autologous skin epidermal cell sheets would be useful in preventing severe esophageal constriction after circumferential ESD. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  5. Inertial migrations of cylindrical particles in rectangular microchannels: Variations of equilibrium positions and equivalent diameters

    NASA Astrophysics Data System (ADS)

    Su, Jinghong; Chen, Xiaodong; Hu, Guoqing

    2018-03-01

    Inertial migration has emerged as an efficient tool for manipulating both biological and engineered particles that commonly exist with non-spherical shapes in microfluidic devices. There have been numerous studies on the inertial migration of spherical particles, whereas the non-spherical particles are still largely unexplored. Here, we conduct three-dimensional direct numerical simulations to study the inertial migration of rigid cylindrical particles in rectangular microchannels with different width/height ratios under the channel Reynolds numbers (Re) varying from 50 to 400. Cylindrical particles with different length/diameter ratios and blockage ratios are also concerned. Distributions of surface force with the change of rotation angle show that surface stresses acting on the particle end near the wall are the major contributors to the particle rotation. We obtain lift forces experienced by cylindrical particles at different lateral positions on cross sections of two types of microchannels at various Re. It is found that there are always four stable equilibrium positions on the cross section of a square channel, while the stable positions are two or four in a rectangular channel, depending on Re. By comparing the equilibrium positions of cylindrical particles and spherical particles, we demonstrate that the equivalent diameter of cylindrical particles monotonously increases with Re. Our work indicates the influence of a non-spherical shape on the inertial migration and can be useful for the precise manipulation of non-spherical particles.

  6. Changes in esophageal motility after endoscopic submucosal dissection for superficial esophageal cancer: a high-resolution manometry study.

    PubMed

    Takahashi, K; Sato, Y; Takeuchi, M; Sato, H; Nakajima, N; Ikarashi, S; Hayashi, K; Mizuno, K-I; Honda, Y; Hashimoto, S; Yokoyama, J; Terai, S

    2017-11-01

    The effect of endoscopic submucosal dissection (ESD) on esophageal motility remains unknown. Therefore, the aim of this study is to elucidate changes in esophageal motility after ESD along with the cause of dysphagia using high-resolution manometry (HRM). This is a before-and-after trial of the effect of ESD on the esophageal motility. Twenty patients who underwent ESD for superficial esophageal carcinoma were enrolled in this study. Patients filled out a questionnaire about dysphagia and underwent HRM before and after ESD. Results before and after ESD were compared. Data were obtained from 19 patients. The number of patients who complained of dysphagia before and after ESD was 1/19 (5.3%) and 6/19 (31.6%), respectively (P = 0.131). Scores from the five-point Likert scale before and after ESD were 0.1 ± 0.5 and 1.0 ± 1.6, respectively (P = 0.043). The distal contractile integral (DCI) before and after ESD and the number of failed, weak, or fragmented contractions were not significantly different. However, in five patients with circumferential ESD, DCI was remarkably decreased and the frequency of fail, weak, or fragmented contractions increased. Univariate regression analysis showed a relatively strong inverse correlation of ΔDCI with the circumferential mucosal defect ratio {P < 0.01, standardized regression coefficient (r) = -0.65}, the number of stricture preventions (P < 0.01, r = -0.601), and the number of stricture resolutions (P < 0.01, r = -0.77). This HRM study showed that impairment of esophageal motility could be caused by ESD. The impairment of esophageal motility was conspicuous, especially in patients with circumferential ESD and subsequent procedures such as endoscopic triamcinolone injection and endoscopic balloon dilatation. Impaired esophageal motility after ESD might explain dysphagia. © The Authors 2017. Published by Oxford University Press on behalf of International Society for Diseases of the Esophagus. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Deoxyelephantopin from Elephantopus scaber L. induces cell-cycle arrest and apoptosis in the human nasopharyngeal cancer CNE cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Su, Miaoxian; Chung, Hau Yin, E-mail: anthonychung@cuhk.edu.hk; Food and Nutritional Sciences Programme, School of Life Sciences, The Chinese University of Hong Kong, Hong Kong SAR

    2011-07-29

    Highlights: {yields} Deoxyelephantopin (ESD) inhibited cell proliferation in the human nasopharyngeal cancer CNE cells. {yields} ESD induced cell cycle arrest in S and G2/M phases via modulation of cell cycle regulatory proteins. {yields} ESD triggered apoptosis by dysfunction of mitochondria and induction of both intrinsic and extrinsic apoptotic signaling pathways. {yields} ESD also triggered Akt, ERK, and JNK signaling pathways. -- Abstract: Deoxyelephantopin (ESD), a naturally occurring sesquiterpene lactone present in the Chinese medicinal herb, Elephantopus scaber L. exerted anticancer effects on various cultured cancer cells. However, the cellular mechanisms by which it controls the development of the cancer cellsmore » are unavailable, particularly the human nasopharyngeal cancer CNE cells. In this study, we found that ESD inhibited the CNE cell proliferation. Cell cycle arrest in S and G2/M phases was also found. Western blotting analysis showed that modulation of cell cycle regulatory proteins was responsible for the ESD-induced cell cycle arrest. Besides, ESD also triggered apoptosis in CNE cells. Dysfunction in mitochondria was found to be associated with the ESD-induced apoptosis as evidenced by the loss of mitochondrial membrane potential ({Delta}{Psi}m), the translocation of cytochrome c, and the regulation of Bcl-2 family proteins. Despite the Western blotting analysis showed that both intrinsic and extrinsic apoptotic pathways (cleavage of caspases-3, -7, -8, -9, and -10) were triggered in the ESD-induced apoptosis, additional analysis also showed that the induction of apoptosis could be achieved by the caspase-independent manner. Besides, Akt, ERK and JNK pathways were found to involve in ESD-induced cell death. Overall, our findings provided the first evidence that ESD induced cell cycle arrest, and apoptosis in CNE cells. ESD could be a potential chemotherapeutic agent in the treatment of nasopharyngeal cancer (NPC).« less

  8. New Crustal Field Models of Mars

    NASA Astrophysics Data System (ADS)

    Mittelholz, A.; Morschhauser, A.; Johnson, C.

    2017-12-01

    The crustal magnetic field on Mars has been subject of extensive analysis, as it provides us with information about the history of the dynamo, the iron mineralogy of the crust, and the processes that have affected the acquisition and any subsequent modification of crustal magnetization. Mars Global Surveyor (MGS) measured strong, localized crustal magnetic fields, mostly occurring in the southern hemisphere. MGS data were taken mostly at altitudes of 360 - 440 km, with limited (geographically and in local time) observations obtained at lower altitudes. The Mars Atmosphere and Volatile EvolutioN (MAVEN) spacecraft has been in orbit since 2014. MAVEN magnetic field data complement those from MGS by globally expanding the spatial data distribution down to altitudes of 130 km, thus constraining shorter-wavelength structure in the field. Morschhauser et al. (2014) used the full MGS data set to build a spherical harmonic model for the crustal magnetic field up to spherical harmonic degree (l) and order (m) 110 ( λ≈195 km), while accounting for large-scale fields of non-crustal origin. We adopt a similar modeling approach, incorporating MAVEN data and inverting to higher l,m (e.g., λ≈130 km corresponds to l≈165). In order to avoid leakage of external field signals into the crustal field model, we select only nighttime data, use a modified Huber-Norm to treat data outliers and co-estimate a time-variable external field. We have also used another technique to model the field regionally. In this Equivalent Source Dipole (ESD) approach we solve for the magnetization of an assumed uniformly-magnetized layer, represented by equidistant dipoles placed at a single source depth. The ESD inversions indicate that shorter wavelength, weak signals are indeed resolvable in the MAVEN data. A comparison of the field models resulting from the two inversion techniques allows us to confidently identify new lithospheric field information available from the MAVEN observations.

  9. Challenges of Implementing ESD in the Education Sector; Experiences in Norway

    NASA Astrophysics Data System (ADS)

    Sandås, Astrid; Benedict, Faye

    This article presents and reflects on Norwegian experiences over a period of about 15 years with implementing the Norwegian national strategy for education for sustainable development (ESD) in the education system. We extract lessons about integration of ESD into education systems. After an introduction to central ideas of sustainable development and ESD, the article discusses the need for appropriate strategies and instruments. Key factors are collaboration to allow pupils and schools to actively contribute to a positive development locally and globally, interdisciplinary approaches to complex sustainability issues, and appropriate use of the ICT and other media. ESD programmes and activities should support school development and build the capacity of schools and teachers for integration of ESD.

  10. Multiple Geographical Origins of Environmental Sex Determination enhanced the diversification of Darwin's Favourite Orchids.

    PubMed

    Pérez-Escobar, Oscar Alejandro; Chomicki, Guillaume; Condamine, Fabien L; de Vos, Jurriaan M; Martins, Aline C; Smidt, Eric C; Klitgård, Bente; Gerlach, Günter; Heinrichs, Jochen

    2017-10-10

    Environmental sex determination (ESD) - a change in sexual function during an individual life span driven by environmental cues - is an exceedingly rare sexual system among angiosperms. Because ESD can directly affect reproduction success, it could influence diversification rate as compared with lineages that have alternative reproductive systems. Here we test this hypothesis using a solid phylogenetic framework of Neotropical Catasetinae, the angiosperm lineage richest in taxa with ESD. We assess whether gains of ESD are associated with higher diversification rates compared to lineages with alternative systems while considering additional traits known to positively affect diversification rates in orchids. We found that ESD has evolved asynchronously three times during the last ~5 Myr. Lineages with ESD have consistently higher diversification rates than related lineages with other sexual systems. Habitat fragmentation due to mega-wetlands extinction, and climate instability are suggested as the driving forces for ESD evolution.

  11. Second Breakdown of 18V Grounded Gate NMOS induced by the Kirk Effect under Electrostatic Discharge

    NASA Astrophysics Data System (ADS)

    Jeon, Byung-Chul; Lee, Seung-Chul; Han, Min-Koo

    2003-09-01

    Electrostatic Discharge (ESD) failure mechanisms of 18V grounded gate NMOS (GGNMOS) for liquid crystal display driver IC (LDI) applications are investigated and effects of layout design parameters on the ESD immunity level are analyzed. Experimental results show that 18V GGNMOS exhibits snapback characteristics and the ESD immunity level is rather high when XO (N-drift overlap over n+ source/drain) is sufficiently large, while GGNMOS does not exhibit the sustaining region and is very vulnerable to ESD stress when XO is relatively small. Simulation results show that the ESD failure mechanism of 18V GGNMOS could be the low-temperature second breakdown induced by the Kirk effect. It is inferred that a certain amount of XO is indispensable to ensure snapback characteristics and high ESD immunity level. Simulation results also show that the ESD immunity level is increased as drain contact to gate space (DCGS) is increased.

  12. A Priority for ESD Research: Influencing Adult Citizens

    ERIC Educational Resources Information Center

    Monroe, Martha C.

    2007-01-01

    Research in the disciplines of education, science education, and environmental education has a rich history. While research in Education for Sustainable Development (ESD) may be related to these traditions, there is a need for ESD to carve a new niche that promotes high quality and effective ESD programmes. With an eye towards practice and applied…

  13. Step-up training for colorectal and gastric ESD and the challenge of ESD training in the proximal colon: results from a German Center.

    PubMed

    Ebigbo, Alanna; Probst, Andreas; Römmele, Christoph; Messmann, Helmut

    2018-05-01

    The endoscopic submucosal dissection (ESD) of cancerous and precancerous lesions in the gastrointestinal (GI) tract is an effective but difficult-to-learn procedure, especially for Western endoscopists. We developed a step-up training protocol and evaluated its outcome on a single endoscopist using specific performance measures. The training protocol included a 12-month period of 50 observational and supervised ESD cases as well as 24 animal procedures. After completion of the protocol, ESD competency was evaluated in the first 30 independent ESD cases. Majority of lesions were located in the stomach and rectum. Performance measures included R0-resection rate, complication rate and resection speed. R0 resection rate was 93 %, complication rate was 7 % and median resection speed was 6,77 cm 2 /h. 1 case of delayed perforation with subsequent hemicolectomy occurred in the descending colon. The ESD step-up training protocol used in this study on a single endoscopist showed excellent outcomes for lesions in the rectum and stomach. However, ESD training in the upper colon remains a challenge.

  14. Safe procedure in endoscopic submucosal dissection for colorectal tumors focused on preventing complications

    PubMed Central

    Yoshida, Naohisa; Yagi, Nobuaki; Naito, Yuji; Yoshikawa, Toshikazu

    2010-01-01

    Endoscopic submucosal dissection (ESD) is efficient for en bloc resection of large colorectal tumors. However, it has several technical difficulties, because the wall of the colon is thin and due to the winding nature of the colon. The main complications of ESD comprise postoperative perforation and hemorrhage, similar to endoscopic mucosal resection (EMR). In particular, the rate of perforation in ESD is higher than that in EMR. Perforation of the colon can cause fatal peritonitis. Endoscopic clipping is reported to be an efficient therapy for perforation. Most cases with perforation are treated conservatively without urgent surgical intervention. However, the rate of postoperative hemorrhage in ESD is similar to that in EMR. Endoscopic therapy including endoscopic clipping is performed and most of the cases are treated conservatively without blood transfusion. In blood examination, some degree of inflammation is detected after ESD. For the standardization of ESD, it is most important to decrease the rate of perforation. Adopting a safe strategy for ESD and a suitable choice of knife are both important ways of preventing perforation. Moreover, appropriate training and increasing experience can improve the endoscopic technique and can decrease the rate of perforation. In this review, we describe safe procedures in ESD to prevent complications, the complications of ESD and their management. PMID:20379999

  15. Examination of a high resolution laser optical plankton counter and FlowCAM for measuring plankton concentration and size

    NASA Astrophysics Data System (ADS)

    Kydd, Jocelyn; Rajakaruna, Harshana; Briski, Elizabeta; Bailey, Sarah

    2018-03-01

    Many commercial ships will soon begin to use treatment systems to manage their ballast water and reduce the global transfer of harmful aquatic organisms and pathogens in accordance with upcoming International Maritime Organization regulations. As a result, rapid and accurate automated methods will be needed to monitoring compliance of ships' ballast water. We examined two automated particle counters for monitoring organisms ≥ 50 μm in minimum dimension: a High Resolution Laser Optical Plankton Counter (HR-LOPC), and a Flow Cytometer with digital imaging Microscope (FlowCAM), in comparison to traditional (manual) microscopy considering plankton concentration, size frequency distributions and particle size measurements. The automated tools tended to underestimate particle concentration compared to standard microscopy, but gave similar results in terms of relative abundance of individual taxa. For most taxa, particle size measurements generated by FlowCAM ABD (Area Based Diameter) were more similar to microscope measurements than were those by FlowCAM ESD (Equivalent Spherical Diameter), though there was a mismatch in size estimates for some organisms between the FlowCAM ABD and microscope due to orientation and complex morphology. When a single problematic taxon is very abundant, the resulting size frequency distribution curves can become skewed, as was observed with Asterionella in this study. In particular, special consideration is needed when utilizing automated tools to analyse samples containing colonial species. Re-analysis of the size frequency distributions with the removal of Asterionella from FlowCAM and microscope data resulted in more similar curves across methods with FlowCAM ABD having the best fit compared to the microscope, although microscope concentration estimates were still significantly higher than estimates from the other methods. The results of our study indicate that both automated tools can generate frequency distributions of particles that might be particularly useful if correction factors can be developed for known differences in well-studied aquatic ecosystems.

  16. Endoscopic submucosal dissection for early gastric cancer on the lesser curvature in upper third of the stomach is a risk factor for postoperative delayed gastric emptying.

    PubMed

    Yoshizaki, Tetsuya; Obata, Daisuke; Aoki, Yasuhiro; Okamoto, Norihiro; Hashimura, Hiroki; Kano, Chise; Matsushita, Megumi; Kanamori, Atsushi; Matsumoto, Kei; Tsujimae, Masahiro; Momose, Kenji; Eguchi, Takaaki; Okuyama, Shunsuke; Yamashita, Hiroshi; Fujita, Mikio; Okada, Akihiko

    2018-02-07

    Advances in Endoscopic submucosal dissection (ESD) technology have established ESD for early gastric cancer as a safe and stable technique. However, ESD may induce delayed gastric emptying and the cause of food residue retention in the stomach after ESD is not clear. This study aimed to clarify risk factors for delayed gastric emptying with food retention after gastric ESD. We retrospectively examined for food residue in the stomach 1 week after ESD was performed for early gastric carcinoma at Osaka Saiseikai Nakatsu Hospital from February 2008 to November 2016. Food residue was observed in 68 (6.1%) of 1114 patients who underwent gastric ESD. The percentage of lesions located on the lesser curvature of the upper third of the stomach was 45.6% (31/68) in the food residue group and 3.5% (37/1046) in the non-food residue group, which was significantly different (P < 0.01). Multivariate logistic regression analysis revealed that lesions on the lesser curvature of the upper third of the stomach (Odds ratio [OR] 23.31, 95% confidence interval [CI] 12.60-43.61, P < 0.01), post-ESD bleeding (OR 4.25, 95%CI 1.67-9.80, P < 0.01), submucosal invasion (OR 2.80, 95%CI 1.34-5.63, P < 0.01), and age over 80 years (OR 2.34, 95%CI 1.28-4.22, P < 0.01) were independent risk factors for food retention after gastric ESD. Of the 68 patients, 3 had food residue in the stomach on endoscopic examination for follow-up observation after the ESD ulcer had healed. Delayed gastric emptying with food retention after gastric ESD was associated with lesions located in the lesser curvature of the upper stomach, submucosal invasion of the lesion, age older than 80 years, and post-ESD bleeding, though it was temporary in most cases.

  17. Delving into Key Dimensions of ESD through Analyses of a Middle School Science Textbook

    ERIC Educational Resources Information Center

    Sahin, Elvan

    2016-01-01

    Uncertainties and debates regarding the term of sustainable development are still going on, and similarly, the notion of education for sustainable development (ESD) is open to debate. There has been an attempt to make the concept of ESD evident, which is quite challenging. Palmer (1998) stated the appropriateness of ESD within environmental…

  18. Endoscopic submucosal dissection for early esophageal neoplasms using the stag beetle knife

    PubMed Central

    Kuwai, Toshio; Yamaguchi, Toshiki; Imagawa, Hiroki; Miura, Ryoichi; Sumida, Yuki; Takasago, Takeshi; Miyasako, Yuki; Nishimura, Tomoyuki; Iio, Sumio; Yamaguchi, Atsushi; Kouno, Hirotaka; Kohno, Hiroshi; Ishaq, Sauid

    2018-01-01

    AIM To determine short- and long-term outcomes of endoscopic submucosal dissection (ESD) using the stag beetle (SB) knife, a scissor-shaped device. METHODS Seventy consecutive patients with 96 early esophageal neoplasms, who underwent ESD using a SB knife at Kure Medical Center and Chugoku Cancer Center, Japan, between April 2010 and August 2016, were retrospectively evaluated. Clinicopathological characteristics of lesions and procedural adverse events were assessed. Therapeutic success was evaluated on the basis of en bloc, histologically complete, and curative or non-curative resection rates. Overall and tumor-specific survival, local or distant recurrence, and 3- and 5-year cumulative overall metachronous cancer rates were also assessed. RESULTS Eligible patients had dysplasia/intraepithelial neoplasia (22%) or early cancers (squamous cell carcinoma, 78%). The median procedural time was 60 min and on average, the lesions measured 24 mm in diameter, yielding 33-mm tissue defects. The en bloc resection rate was 100%, with 95% and 81% of dissections deemed histologically complete and curative, respectively. All procedures were completed without accidental incisions/perforations or delayed bleeding. During follow-up (mean, 35 ± 23 mo), no local recurrences or metastases were observed. The 3- and 5-year survival rates were 83% and 70%, respectively, with corresponding rates of 85% and 75% for curative resections and 74% and 49% for non-curative resections. The 3- and 5-year cumulative rates of metachronous cancer in the patients with curative resections were 14% and 26%, respectively. CONCLUSION ESD procedures using the SB knife are feasible, safe, and effective for treating early esophageal neoplasms, yielding favorable short- and long-term outcomes. PMID:29686470

  19. Endoscopic submucosal dissection for early esophageal neoplasms using the stag beetle knife.

    PubMed

    Kuwai, Toshio; Yamaguchi, Toshiki; Imagawa, Hiroki; Miura, Ryoichi; Sumida, Yuki; Takasago, Takeshi; Miyasako, Yuki; Nishimura, Tomoyuki; Iio, Sumio; Yamaguchi, Atsushi; Kouno, Hirotaka; Kohno, Hiroshi; Ishaq, Sauid

    2018-04-21

    To determine short- and long-term outcomes of endoscopic submucosal dissection (ESD) using the stag beetle (SB) knife, a scissor-shaped device. Seventy consecutive patients with 96 early esophageal neoplasms, who underwent ESD using a SB knife at Kure Medical Center and Chugoku Cancer Center, Japan, between April 2010 and August 2016, were retrospectively evaluated. Clinicopathological characteristics of lesions and procedural adverse events were assessed. Therapeutic success was evaluated on the basis of en bloc , histologically complete, and curative or non-curative resection rates. Overall and tumor-specific survival, local or distant recurrence, and 3- and 5-year cumulative overall metachronous cancer rates were also assessed. Eligible patients had dysplasia/intraepithelial neoplasia (22%) or early cancers (squamous cell carcinoma, 78%). The median procedural time was 60 min and on average, the lesions measured 24 mm in diameter, yielding 33-mm tissue defects. The en bloc resection rate was 100%, with 95% and 81% of dissections deemed histologically complete and curative, respectively. All procedures were completed without accidental incisions/perforations or delayed bleeding. During follow-up (mean, 35 ± 23 mo), no local recurrences or metastases were observed. The 3- and 5-year survival rates were 83% and 70%, respectively, with corresponding rates of 85% and 75% for curative resections and 74% and 49% for non-curative resections. The 3- and 5-year cumulative rates of metachronous cancer in the patients with curative resections were 14% and 26%, respectively. ESD procedures using the SB knife are feasible, safe, and effective for treating early esophageal neoplasms, yielding favorable short- and long-term outcomes.

  20. Calibration of optical particle-size analyzer

    DOEpatents

    Pechin, William H.; Thacker, Louis H.; Turner, Lloyd J.

    1979-01-01

    This invention relates to a system for the calibration of an optical particle-size analyzer of the light-intercepting type for spherical particles, wherein a rotary wheel or disc is provided with radially-extending wires of differing diameters, each wire corresponding to a particular equivalent spherical particle diameter. These wires are passed at an appropriate frequency between the light source and the light detector of the analyzer. The reduction of light as received at the detector is a measure of the size of the wire, and the electronic signal may then be adjusted to provide the desired signal for corresponding spherical particles. This calibrator may be operated at any time without interrupting other processing.

  1. ESD Implementation at the School Organisation Level, Part 1--Investigating the Quality Criteria Guiding School Leaders' Work at Recognized ESD Schools

    ERIC Educational Resources Information Center

    Mogren, Anna; Gericke, Niklas

    2017-01-01

    Research on Education for Sustainable Development (ESD) implementation tends to focus primarily on student and teacher outcomes, and there have been few studies on leadership practices at the school organisation level that provide information on how quality in education contributes to ESD implementation. To address this issue, we conducted an…

  2. Electrostatic Discharge Effects on Thin Film Resistors

    NASA Technical Reports Server (NTRS)

    Sampson, Michael J.; Hull, Scott M.

    1999-01-01

    Recently, open circuit failures of individual elements in thin film resistor networks have been attributed to electrostatic discharge (ESD) effects. This paper will discuss the investigation that came to this conclusion and subsequent experimentation intended to characterize design factors that affect the sensitivity of resistor elements to ESD. The ESD testing was performed using the standard human body model simulation. Some of the design elements to be evaluated were: trace width, trace length (and thus width to length ratio), specific resistivity of the trace (ohms per square) and resistance value. However, once the experiments were in progress, it was realized that the ESD sensitivity of most of the complex patterns under evaluation was determined by other design and process factors such as trace shape and termination pad spacing. This paper includes pictorial examples of representative ESD failure sites, and provides some options for designing thin film resistors that are ESD resistant. The risks of ESD damage are assessed and handling precautions suggested.

  3. Collisions of droplets on spherical particles

    NASA Astrophysics Data System (ADS)

    Charalampous, Georgios; Hardalupas, Yannis

    2017-10-01

    Head-on collisions between droplets and spherical particles are examined for water droplets in the diameter range between 170 μm and 280 μm and spherical particles in the diameter range between 500 μm and 2000 μm. The droplet velocities range between 6 m/s and 11 m/s, while the spherical particles are fixed in space. The Weber and Ohnesorge numbers and ratio of droplet to particle diameter were between 92 < We < 1015, 0.0070 < Oh < 0.0089, and 0.09 < Ω < 0.55, respectively. The droplet-particle collisions are first quantified in terms of the outcome. In addition to the conventional deposition and splashing regimes, a regime is observed in the intermediate region, where the droplet forms a stable crown, which does not breakup but propagates along the particle surface and passes around the particle. This regime is prevalent when the droplets collide on small particles. The characteristics of the collision at the onset of rim instability are also described in terms of the location of the film on the particle surface and the orientation and length of the ejected crown. Proper orthogonal decomposition identified that the first 2 modes are enough to capture the overall morphology of the crown at the splashing threshold.

  4. Pyrolysis of Large Black Liquor Droplets

    NASA Technical Reports Server (NTRS)

    Bartkus, Tadas P.; Dietrich, Daniel L.; T'ien, James S.; Wessel, Richard A.

    2007-01-01

    This paper presents the results of experiments involving the pyrolysis of large black liquor droplets in the NASA KC-135 reduced gravity aircraft. The reduced gravity environment facilitated the study of droplets up to 9 mm in diameter extending the results of previous studies to droplet sizes that are similar to those encountered in recovery boilers. Single black liquor droplets were rapidly inserted into a 923 K oven. The primary independent variables were the initial droplet diameter (0.5 mm to 9 mm), the black liquor solids content (66.12% - 72.9% by mass), and the ambient oxygen mole fraction (0.0 - 0.21). Video records of the experiments provided size and shape of the droplets as a function of time. The results show that the particle diameter at the end of the drying stage (D(sub DRY)) increases linearly with the initial particle diameter (D(sub O)). The results further show that the ratio of the maximum swollen diameter (D(sub MAX)) to D(sub O) decreases with increasing D(sub O) for droplets with D(sub O) less than 4 mm. This ratio was independent of D(sub O) for droplets with D(sub O) greater than 4 mm. The particle is most spherical at the end of drying, and least spherical at maximum swollen size, regardless of initial sphericity and droplet size.

  5. Pyrolysis of Large Black Liquor Droplets

    NASA Technical Reports Server (NTRS)

    Bartkus, Tadas P.; T'ien, James S.; Dietrich, Daniel L.; Wessel, Richard A.

    2007-01-01

    This paper presents the results of experiments involving the pyrolysis of large black liquor droplets in the NASA KC-135 reduced gravity aircraft. The reduced gravity environment facilitated the study of droplets up to 9 mm in diameter extending the results of previous studies to droplet sizes that are similar to those encountered in recovery boilers. Single black liquor droplets were rapidly inserted into a 923 K oven. The primary independent variables were the initial droplet diameter (0.5 mm to 9 mm), the black liquor solids content (66.12% - 72.9% by mass), and the ambient oxygen mole fraction (0.0 - 0.21). Video records of the experiments provided size and shape of the droplets as a function of time. The results show that the particle diameter at the end of the drying stage (D(sub DRY) ) increases linearly with the initial particle diameter (D(sub O)). The results further show that the ratio of the maximum swollen diameter (D(sub MAX)) to D(sub O) decreases with increasing D(sub O) for droplets with D(sub O) less than 4 mm. This ratio was independent of D(sub O) for droplets with D(sub O) greater than 4 mm. The particle is most spherical at the end of drying, and least spherical at maximum swollen size, regardless of initial sphericity and droplet size.

  6. Method to produce large, uniform hollow spherical shells

    DOEpatents

    Hendricks, C.D.

    1983-09-26

    The invention is a method to produce large uniform hollow spherical shells by (1) forming uniform size drops of heat decomposable or vaporizable material, (2) evaporating the drops to form dried particles, (3) coating the dried particles with a layer of shell forming material and (4) heating the composite particles to melt the outer layer and to decompose or vaporize the inner particle to form an expanding inner gas bubble. The expanding gas bubble forms the molten outer layer into a shell of relatively large diameter. By cycling the temperature and pressure on the molten shell, nonuniformities in wall thickness can be reduced. The method of the invention is utilized to produce large uniform spherical shells, in the millimeter to centimeter diameter size range, from a variety of materials and of high quality, including sphericity, concentricity and surface smoothness, for use as laser fusion or other inertial confinement fusion targets as well as other applications.

  7. Efficacy and safety of a novel submucosal lifting gel used for endoscopic submucosal dissection: a study in a porcine model.

    PubMed

    Schölvinck, D W; Alvarez Herrero, L; Goto, O; Meijer, S L; Neuhaus, H; Schumacher, B; Bergman, J J G H M; Weusten, B L A M

    2015-09-01

    Endoscopic submucosal dissection (ESD) is technically demanding. A viscous gel for submucosal lifting might induce mechanical submucosal dissection facilitating easier and safer ESD. In 12 female pigs (median 64 kg), ESDs of simulated lesions were performed at the posterior wall and greater curvature in the gastric body (one ESD per location) with randomly assigned injection fluids: gel or control fluid (0.9% saline with hydroxypropyl methylcellulose 3 mg/ml [7:1] and indigo carmine droplets). Additionally, 10 cc gel was injected into the submucosa at the anterior wall without ESD to assess effects of inappropriate injection. Pigs were euthanized at day 0, 3 or 28. In four additional pigs (euthanized day 3 or 28) 10 cc gel was injected into the muscularis propria (MP) after four endoscopic mucosal resections in the gastric body. Both fluid groups showed equal ESD-procedure times (28 [gel] vs. 26 min [control]) and complications. Gel-ESDs required less accessory interchanges (3.5 vs. 5.5; p = 0.01). Mechanical dissection after circumferential incision was achieved in 25% of gel-ESDs; none in control-ESDs. The severity of inflammation and fibrosis was equal in both fluid groups. Normal architecture and vital mucosa were found after inappropriate submucosal injection. MP-injections resulted in one transmural hematoma (day 3), and intramuscular encapsulation in 25% of the sites (day 28). A pig's stomach differs from the human stomach. The mechanical dissection properties of the gel may reduce the need for submucosal dissection during ESD. The gel is safe when advertently injected in the submucosa and MP. The porcine model appeared suboptimal to evaluate the true mechanical dissection properties of the gel.

  8. Calculation of detonation initiation in a hydrogen/oxygen/argon mixture in by a small-diameter spherical projectile

    NASA Astrophysics Data System (ADS)

    Bedarev, I. A.; Temerbekov, V. M.; Fedorov, A. V.

    2018-03-01

    The initiation of detonation in a reactive mixture by a small-diameter spherical projectile launched at supersonic velocity was studied for a reduced kinetic scheme of chemical reactions. A mathematical technique based on the ANSYS Fluent package was developed for this purpose. Numerical and experimental data on the flow regimes and detonation cell sizes are compared. There is agreement between the calculated and experimental flow patterns and detonation cell sizes for each regime.

  9. Reconstruction of spherically symmetric objects from slit-imaged emission: limitations due to finite slit width

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mueller, M.M.

    1979-11-01

    A simple method for reconstructing spherically symmetric objects from slit-imaged emission was recently described by Vest and Steel. Although this method is valid for infinitesimal slit widths and practically noise-free irradiance data, it is shown here that its validity does not extend to slits of practical width in the laser-fusion program. However, a method is given for reducing the Vest--Steel plots with practical apertures to obtain information on core diameter, shell diameter, and shell thickness.

  10. A Critical Review of Education for Sustainable Development (ESD) in Japan: Beyond the Practice of Pouring New Wine into Old Bottles

    ERIC Educational Resources Information Center

    Nagata, Yoshiyuki

    2017-01-01

    Japan stands as a rare country in which ESD has been incorporated as mainstream policy. However, looking back on the United Nations Decade of Education for Sustainable Development (UNDESD), ESD has not brought about the transformation in Japan that one expects ESD to aim for, despite this support at the policy level. The cause may be that pouring…

  11. Esophageal Motility after Extensive Circumferential Endoscopic Submucosal Dissection for Superficial Esophageal Cancer.

    PubMed

    Kuribayashi, Yasutaka; Iizuka, Toshiro; Nomura, Kosuke; Furuhata, Tsukasa; Yamashita, Satoshi; Matsui, Akira; Kikuchi, Daisuke; Mitani, Toshifumi; Kaise, Mitsuru; Hoteya, Shu

    2018-06-05

    Endoscopic submucosal dissection (ESD) for superficial esophageal cancer is sometimes extensive, and in our experience, patients not infrequently present with dysphagia after ESD even in the absence of esophageal stricture. The aim of this study was to evaluate esophageal motility using high-resolution manometry (HRM) in patients with and without dysphagia after extensive circumferential ESD. HRM was performed in a total of 52 patients who had undergone ESD for superficial esophageal cancer and a mucosal defect after ESD exceeded more than two-thirds of the esophageal circumference. The frequency and type of esophageal dysmotility and the relationship between esophageal motility and dysphagia were evaluated. Esophageal dysmotility was observed in 13 patients (25%): jackhammer esophagus in 4, esophagogastric junction outflow obstruction in 4, absent contractility in 2, and distal esophageal spasm, ineffective esophageal motility, and fragmented peristalsis in 1 patient each. Of the 22 patients with dysphagia after ESD, 9 (41%) had esophageal dysmotility. Of the 30 patients without dysphagia after ESD, 4 (13%) had esophageal dysmotility. The relationship between dysmotility and dysphagia was significant (p = 0.025). Esophageal dysmotility exists in approximately one-quarter of patients after extensive circumferential ESD, which is associated with dysphagia in the absence of esophageal stricture. © 2018 S. Karger AG, Basel.

  12. PREPARATION OF SPHERICAL URANIUM DIOXIDE PARTICLES

    DOEpatents

    Levey, R.P. Jr.; Smith, A.E.

    1963-04-30

    This patent relates to the preparation of high-density, spherical UO/sub 2/ particles 80 to 150 microns in diameter. Sinterable UO/sub 2/ powder is wetted with 3 to 5 weight per cent water and tumbled for at least 48 hours. The resulting spherical particles are then sintered. The sintered particles are useful in dispersion-type fuel elements for nuclear reactors. (AEC)

  13. Multiwalled carbon nanotube monoliths prepared by spark plasma sintering (SPS) and their mechanical properties.

    PubMed

    Uo, Motohiro; Hasegawa, Tomoka; Akasaka, Tsukasa; Tanaka, Isao; Munekane, Fuminori; Omori, Mamoru; Kimura, Hisamichi; Nakatomi, Reiko; Soga, Kohei; Kogo, Yasuo; Watari, Fumio

    2009-01-01

    Three types of multiwalled carbon nanotube (MWCNT) monoliths without any binders were obtained by spark plasma sintering (SPS) treatment at 2000 degrees C under 80 MPa sintering pressure. Three MWCNTs with different diameters: thin (slashed circle20-30 nm, CNT Co., Ltd., Korea), thick (slashed circle100 nm, Nano Carbon Technologies Co., Ltd., Japan) and spherical thin (slashed circle20-30 nm, granulated diameter = 1-3 microm, Shimizu Corporation, Japan) were employed for SPS. SEM observation confirmed that these materials maintained the nanosized tube microstructure of raw CNT powder after SPS treatment. The densest monolith was prepared with the spherical MWCNTs. The mechanical properties of this material were estimated by the dynamic hardness test. The elastic modulus of the monolith did not depend on the difference of MWCNTs, but the hardness of spherical MWCNTs was higher than that of thick MWCNTs. The high density and hardness of the spherical MWCNTs were caused by the high packing density during the SPS process because of its spherical granulation. Thus, the spherical MWCNTs were most useful for the MWCNT monolith preparation with the SPS process and its application as a bone substitute material and a bone tissue engineering scaffold material was suggested.

  14. Magnetic anchor guidance for endoscopic submucosal dissection and other endoscopic procedures

    PubMed Central

    Mortagy, Mohamed; Mehta, Neal; Parsi, Mansour A; Abe, Seiichiro; Stevens, Tyler; Vargo, John J; Saito, Yutaka; Bhatt, Amit

    2017-01-01

    Endoscopic submucosal dissection (ESD) is a well-established, minimally invasive treatment for superficial neoplasms of the gastrointestinal tract. The universal adoption of ESD has been limited by its slow learning curve, long procedure times, and high risk of complications. One technical challenge is the lack of a second hand that can provide traction, as in conventional surgery. Reliable tissue retraction that exposes the submucosal plane of dissection would allow for safer and more efficient dissection. Magnetic anchor guided endoscopic submucosal dissection (MAG-ESD) has potential benefits compared to other current traction methods. MAG-ESD offers dynamic tissue retraction independent of the endoscope mimicking a surgeon’s “second hand”. Two types of magnets can be used: electromagnets and permanent magnets. In this article we review the MAG-ESD technology, published work and studies of magnets in ESD. We also review the use of magnetic anchor guidance systems in natural orifice transluminal endoscopic surgery and the idea of magnetic non-contact retraction using surface ferromagentization. We discuss the current limitations, the future potential of MAG-ESD and the developments needed for adoption of this technology. PMID:28522906

  15. ESD and lifelong learning: a case study of the Shangri-la Institute's current engagement with the Bazhu community in Diqing, China

    NASA Astrophysics Data System (ADS)

    Liu, Yunhua; Constable, Alicia

    2010-06-01

    This article argues that ESD should be integrated into lifelong learning and provides an example of how this might be done. It draws on a case study of a joint project between the Shangri-la Institute and the Bazhu community in Diqing, southwest China, to analyse a community-based approach to Education for Sustainable Development and assess its implications for lifelong learning. The article examines the different knowledge, skills and values needed for ESD across the life span and asserts the need for these competencies to be informed by the local context. The importance of linking ESD with local culture and indigenous knowledge is emphasised. The article goes on to propose methods for integrating ESD into lifelong learning and underscore the need for learning at the individual, institutional and societal levels in formal, non-formal and informal learning settings. It calls for institutional changes that link formal, non-formal and informal learning through the common theme of ESD, and establish platforms to share experiences, reflect on these and thereby continually improve ESD.

  16. Endoscopic submucosal dissection for removal of superficial gastrointestinal neoplasms: A technical review

    PubMed Central

    Matsui, Noriaki; Akahoshi, Kazuya; Nakamura, Kazuhiko; Ihara, Eikichi; Kita, Hiroto

    2012-01-01

    Endoscopic submucosal dissection (ESD) is now the most common endoscopic treatment in Japan for intramucosal gastrointestinal neoplasms (non-metastatic). ESD is an invasive endoscopic surgical procedure, requiring extensive knowledge, skill, and specialized equipment. ESD starts with evaluation of the lesion, as accurate assessment of the depth and margin of the lesion is essential. The devices and strategies used in ESD vary, depending on the nature of the lesion. Prior to the procedure, the operator must be knowledgeable about the treatment strategy(ies), the device(s) to use, the electrocautery machine settings, the substances to inject, and other aspects. In addition, the operator must be able to manage complications, should they arise, including immediate recognition of the complication(s) and its treatment. Finally, in case the ESD treatment is not successful, the operator should be prepared to apply alternative treatments. Thus, adequate knowledge and training are essential to successfully perform ESD. PMID:22523613

  17. On- and off-eye spherical aberration of soft contact lenses and consequent changes of effective lens power.

    PubMed

    Dietze, Holger H; Cox, Michael J

    2003-02-01

    Soft contact lenses produce a significant level of spherical aberration affecting their power on-eye. A simple model assuming that a thin soft contact lens aligns to the cornea predicts that these effects are similar on-eye and off-eye. The wavefront aberration for 17 eyes and 33 soft contact lenses on-eye was measured with a Shack-Hartmann wavefront sensor. The Zernike coefficients describing the on-eye spherical aberration of the soft contact lens were compared with off-eye ray-tracing results. Paraxial and effective lens power changes were determined. The model predicts the on-eye spherical aberration of soft contact lenses closely. The resulting power change for a +/- 7.00 D spherical soft contact lens is +/- 0.5 D for a 6-mm pupil diameter and +/- 0.1 D for a 3-mm pupil diameter. Power change is negligible for soft contact lenses corrected for off-eye spherical aberration. For thin soft contact lenses, the level of spherical aberration and the consequent power change is similar on-eye and off-eye. Soft contact lenses corrected for spherical aberration in air will be expected to be aberration-free on-eye and produce only negligibly small power changes. For soft contact lenses without aberration correction, for higher levels of ametropia and large pupils, the soft contact lens power should be determined with trial lenses with their power and p value similar to the prescribed lens. The benefit of soft contact lenses corrected for spherical aberration depends on the level of ocular spherical aberration.

  18. Practical calibration curve of small-type optically stimulated luminescence (OSL) dosimeter for evaluation of entrance skin dose in the diagnostic X-ray region.

    PubMed

    Takegami, Kazuki; Hayashi, Hiroaki; Okino, Hiroki; Kimoto, Natsumi; Maehata, Itsumi; Kanazawa, Yuki; Okazaki, Tohru; Kobayashi, Ikuo

    2015-07-01

    For X-ray diagnosis, the proper management of the entrance skin dose (ESD) is important. Recently, a small-type optically stimulated luminescence dosimeter (nanoDot OSL dosimeter) was made commercially available by Landauer, and it is hoped that it will be used for ESD measurements in clinical settings. Our objectives in the present study were to propose a method for calibrating the ESD measured with the nanoDot OSL dosimeter and to evaluate its accuracy. The reference ESD is assumed to be based on an air kerma with consideration of a well-known back scatter factor. We examined the characteristics of the nanoDot OSL dosimeter using two experimental conditions: a free air irradiation to derive the air kerma, and a phantom experiment to determine the ESD. For evaluation of the ability to measure the ESD, a calibration curve for the nanoDot OSL dosimeter was determined in which the air kerma and/or the ESD measured with an ionization chamber were used as references. As a result, we found that the calibration curve for the air kerma was determined with an accuracy of 5 %. Furthermore, the calibration curve was applied to the ESD estimation. The accuracy of the ESD obtained was estimated to be 15 %. The origin of these uncertainties was examined based on published papers and Monte-Carlo simulation. Most of the uncertainties were caused by the systematic uncertainty of the reading system and the differences in efficiency corresponding to different X-ray energies.

  19. Treatment of gastric remnant cancer post distal gastrectomy by endoscopic submucosal dissection using an insulation-tipped diathermic knife

    PubMed Central

    Hirasaki, Shoji; Kanzaki, Hiromitsu; Matsubara, Minoru; Fujita, Kohei; Matsumura, Shuji; Suzuki, Seiyuu

    2008-01-01

    AIM: To evaluate the effectiveness of endoscopic submucosal dissection using an insulation-tipped diathermic knife (IT-ESD) for the treatment of patients with gastric remnant cancer. METHODS: Thirty-two patients with early gastric cancer in the remnant stomach, who underwent distal gastrectomy due to gastric carcinoma, were treated with endoscopic mucosal resection (EMR) or ESD at Sumitomo Besshi Hospital and Shikoku Cancer Center in the 10-year period from January 1998 to December 2007, including 17 patients treated with IT-ESD. Retrospectively, patient backgrounds, the one-piece resection rate, complete resection (CR) rate, operation time, bleeding rate, and perforation rate were compared between patients treated with conventional EMR and those treated with IT-ESD. RESULTS: The CR rate (40% in the EMR group vs 82% in the IT-ESD group) was significantly higher in the IT-ESD group than in the EMR group; however, the operation time was significantly longer for the IT-ESD group (57.6 ± 31.9 min vs 21.1 ± 12.2 min). No significant differences were found in the rate of underlying cardiopulmonary disease (IT-ESD group, 12% vs EMR group, 13%), one-piece resection rate (100% vs 73%), bleeding rate (18% vs 6.7%), and perforation rate (0% vs 0%) between the two groups. CONCLUSION: IT-ESD appears to be an effective treatment for gastric remnant cancer post distal gastrectomy because of its high CR rate. It is useful for histological confirmation of successful treatment. The long-term outcome needs to be evaluated in the future. PMID:18442204

  20. Radiofrequency Ablation Versus Endoscopic Submucosal Dissection in Treating Large Early Esophageal Squamous Cell Neoplasia

    PubMed Central

    Wang, Wen-Lun; Chang, I-Wei; Chen, Chien-Chuan; Chang, Chi-Yang; Mo, Lein-Ray; Lin, Jaw-Town; Wang, Hsiu-Po; Lee, Ching-Tai

    2015-01-01

    Abstract Radiofrequency ablation (RFA) and endoscopic submucosal dissection (ESD) can potentially be applied for early esophageal squamous cell neoplasia (ESCN); however, no study has directly compared these 2 modalities. We retrospectively enrolled the patients with flat-type “large” (length ≥3 cm extending ≥1/2 of the circumference of esophagus) early ESCNs treated endoscopically. The main outcome measurements were complete response at 12 months, and adverse events. Of a total of 65 patients, 18 were treated with RFA and 47 with ESD. The procedure time of RFA was significantly shorter than that of ESD (126.6 vs 34.8 min; P < 0.001). The complete resection rate of ESD and complete response rate after primary RFA were 89.3% and 77.8%, respectively. Based on the histological evaluation of the post-ESD specimens showed 14 of 47 (29.8%) had histological upstaging compared with the pre-ESD biopsies, and 4 of them had lymphovascular invasion requiring chemoradiation or surgery. After additional therapy for residual lesions, 46 (97.9%) patients in the ESD group and 17 (94.4%) patients in the RFA group achieved a complete response at 12 months. Four patients (8.5%) developed major procedure-related adverse events in the ESD group, but none in the RFA group. In patients with lesions occupying more than 3/4 of the circumference, a significantly higher risk of esophageal stenosis was noted in the ESD group compared with RFA group (83% vs 27%, P = 0.01), which required more sessions of dilatation to resolve the symptoms (median, 13 vs 3, P = 0.04). There were no procedure-related mortality or neoplastic progression in either group; however, 1 patient who received ESD and 1 who received RFA developed local recurrence during a median follow-up period of 32.4 (range, 13–68) and 18.0 (range, 13–41) months, respectively. RFA and ESD are equally effective in the short-term treatment of early flat large ESCNs; however, more adverse events occur with ESD, especially in lesions extending more than 3/4 of the circumference. RFA does not allow for pathology to evaluate the curability after ablation, and thus currently the use for invasive ESCNs should be conservative until longer follow-up studies are available. PMID:26656367

  1. Risk factors for post-colorectal endoscopic submucosal dissection (ESD) coagulation syndrome: a multicenter, prospective, observational study

    PubMed Central

    Arimoto, Jun; Higurashi, Takuma; Kato, Shingo; Fuyuki, Akiko; Ohkubo, Hidenori; Nonaka, Takashi; Yamaguchi, Yoshikazu; Ashikari, Keiichi; Chiba, Hideyuki; Goto, Shungo; Taguri, Masataka; Sakaguchi, Takashi; Atsukawa, Kazuhiro; Nakajima, Atsushi

    2018-01-01

    Background and study aims  Colorectal cancer (CRC) is one of the most common neoplasms and endoscopic submucosal dissection (ESD) is an effective treatment for early-stage CRC. However, it has been observed that patients undergoing ESD often complain of pain, even if ESD has been successfully performed. Risk factors for such pain still remain unknown. The aim of this study was to explore the risk factors for post-colorectal ESD coagulation syndrome (PECS). Patients and methods  This was a prospective multicenter observational trial (UMIN000016781) conducted in 106 of 223 patients who underwent ESD between March 2015 and April 2016. We investigated age, sex, tumor location, ESD operation time, lesion size, duration of hospitalization, and frequency of PECS. We defined PECS as local abdominal pain (evaluated on a visual analogue scale) in the region corresponding to the site of the ESD that occurred within 4 days of the procedure. Results  PECS occurred in 15/106 (14.2 %), and 10 were women ( P  = 0.01, OR: 7.74 [1.6 – 36.4]), 7 had lesions in the cecum ( P  < 0.001, OR: 20.6 [3.7 – 115.2]), and 9 in whom ESD operation time was > 90 min ( P  = 0.002, OR: 10.3 [2.4 – 44.6]). Frequency of deviation from the prescribed clinical path was significantly higher (47 % [7/15] vs. 2 % [2/91], P  < 0.001, OR: 38.9 [6.9 – 219.6]), and hospital stay was significantly longer in the PECS group.  Conclusions  Female gender, location of lesion in the cecum, and ESD operation time > 90 minutes were significant risk factors independent of PECS. These findings are important to management of PECS.  PMID:29527556

  2. Two-dimensional shear wave elastography of breast lesions: Comparison of two different systems.

    PubMed

    Ren, Wei-Wei; Li, Xiao-Long; He, Ya-Ping; Li, Dan-Dan; Wang, Dan; Zhao, Chong-Ke; Bo, Xiao-Wan; Liu, Bo-Ji; Yue, Wen-Wen; Xu, Hui-Xiong

    2017-01-01

    To evaluate the diagnostic performance of two different shear wave elastography (SWE) techniques in distinguishing malignant breast lesions from benign ones. From March 2016 to May 2016, a total of 153 breast lesions (mean diameter, 16.8 mm±10.5; range 4.1-90.0 mm) in 153 patients (mean age, 46.4 years±15.1; age range 20-86 years) were separately performed by two different SWE techniques (i.e. T-SWE, Aplio500, Toshiba Medical System, Tochigi, Japan; and S-SWE, the Aixplorer US system, SuperSonic Imagine, Provence, France). The maximum (Emax), mean (Emean) and standard deviation (ESD) of elasticity modulus values in T-SWE and S-SWE were analyzed. All the lesions were confirmed by ultrasound (US)-guided core needle biopsy (n = 26), surgery (n = 122), or both (n = 5), with pathological results as the gold standard. The areas under the receiver operating characteristic curves (AUROCs) were calculated. Sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV) were calculated to assess the diagnostic performance between T-SWE and S-SWE. Operator consistency was also evaluated. Among the 153 lesions, 41 (26.8%) were malignant and 112 (73.2%) were benign. Emax (T-SWE: 40.10±37.14 kPa vs. 118.78±34.41 kPa; S-SWE: 41.22±22.54 kPa vs. 134.77±60.51 kPa), Emean (T-SWE: 19.75±16.31 kPa vs. 52.93±25.75 kPa; S-SWE: 20.95±10.98 kPa vs. 55.95±22.42 kPa) and ESD (T-SWE: 9.00±8.55 kPa vs. 38.44±12.30 kPa; S-SWE: 8.17±6.14 kPa vs. 29.34±13.88 kPa) showed statistical differences in distinguishing malignant lesions from benign ones both in T-SWE and S-SWE (all p < 0.05). In T-SWE, the diagnostic performance of ESD was the highest (AUROC = 0.958), followed by Emax (AUROC = 0.909; p = 0.001 in comparison with ESD) and Emean (AUROC = 0.892; p < 0.001 in comparison with ESD), while in S-SWE, the diagnostic performance of Emax was the highest (AUROC = 0.967), followed by ESD (AUROC = 0.962, p > 0.05 in comparison with Emax) and Emean (AUROC = 0.930, p = 0.034 in comparison with Emax). AUROC-max (T-SWE: 0.909 vs. 0.967), AUROC-mean (T-SWE: 0.892 vs. 0.930) and AUROC-SD (T-SWE: 0.958 vs. 0.962) showed no significant difference between T-SWE and S-SWE (all p > 0.05). The intra-class correlation coefficients (ICC) of the intra-operator consistency and inter-operator consistency respectively were 0.961 and 0.898 in T-SWE, while 0.954 and 0.897 in S-SWE. T-SWE and S-SWE are equivalent for distinguishing the breast lesions. In T-SWE, ESD had the best diagnostic performance, while in S-SWE, Emax had the best diagnostic performance.

  3. High ESD Breakdown-Voltage InP HBT Transimpedance Amplifier IC for Optical Video Distribution Systems

    NASA Astrophysics Data System (ADS)

    Sano, Kimikazu; Nagatani, Munehiko; Mutoh, Miwa; Murata, Koichi

    This paper is a report on a high ESD breakdown-voltage InP HBT transimpedance amplifier IC for optical video distribution systems. To make ESD breakdown-voltage higher, we designed ESD protection circuits integrated in the TIA IC using base-collector/base-emitter diodes of InP HBTs and resistors. These components for ESD protection circuits have already existed in the employed InP HBT IC process, so no process modifications were needed. Furthermore, to meet requirements for use in optical video distribution systems, we studied circuit design techniques to obtain a good input-output linearity and a low-noise characteristic. Fabricated InP HBT TIA IC exhibited high human-body-model ESD breakdown voltages (±1000V for power supply terminals, ±200V for high-speed input/output terminals), good input-output linearity (less than 2.9-% duty-cycle-distortion), and low noise characteristic (10.7pA/√Hz averaged input-referred noise current density) with a -3-dB-down higher frequency of 6.9GHz. To the best of our knowledge, this paper is the first literature describing InP ICs with high ESD-breakdown voltages.

  4. Complete closure of artificial gastric ulcer after endoscopic submucosal dissection by combined use of a single over-the-scope clip and through-the-scope clips (with videos).

    PubMed

    Maekawa, Satoshi; Nomura, Ryosuke; Murase, Takayuki; Ann, Yasuyoshi; Harada, Masaru

    2015-02-01

    A 5-7 day hospital stay is usually needed after endoscopic submucosal dissection (ESD) of gastric tumor because of the possibility of delayed perforation or bleeding. The aim of this study was to evaluate the efficacy of combined use of a single over-the-scope clip (OTSC) and through-the-scope clips (TTSCs) to achieve complete closure of artificial gastric ulcer after ESD. We prospectively studied 12 patients with early gastric cancer or gastric adenoma. We performed complete closure of post-ESD artificial gastric ulcer using a combination of a single OTSC and TTSCs. Mean size of post-ESD artificial ulcer was 54.6 mm. The mean operating time for the closure procedure was 15.2 min., and the success rate was 91.7 % (11/12). Patients who underwent complete closure of post-ESD artificial gastric ulcer could be discharged the day after ESD and the closing procedure. Complete closure of post-ESD artificial gastric ulcer using a combination of a single OTSC and TTSCs is useful for shortening the period of hospitalization and reducing treatment cost.

  5. Machine imparting complex rotary motion for lapping a spherical inner diameter

    DOEpatents

    Carroll, Thomas A.; Yetter, Harold H.

    1986-01-01

    An apparatus for imparting complex rotary motion is used to lap an inner spherical diameter surface of a workpiece. A lapping tool consists of a dome and rod mounted along the dome's vertical axis. The workpiece containing the lapping tool is held in a gimbal which uses power derived from a secondary takeoff means to impart rotary motion about a horizontal axis. The gimbal is rotated about a vertical axis by a take means while mounted at a radially outward position on a rotating arm.

  6. Machine imparting complex rotary motion for lapping a spherical inner diameter

    DOEpatents

    Carroll, T.A.; Yetter, H.H.

    1985-01-30

    An apparatus for imparting complex rotary motion is used to lap an inner spherical diameter surface of a workpiece. A lapping tool consists of a dome and rod mounted along the dome's vertical axis. The workpiece containing the lapping tool is held in a gimbal which uses power derived from a secondary takeoff means to impart rotary motion about a horizontal axis. The gimbal is rotated about a vertical axis by a take means while mounted at a radially outward position on a rotating arm.

  7. Five-hundred-meter Aperture Spherical Telescope, China

    NASA Image and Video Library

    2016-09-07

    The Five-hundred-meter Aperture Spherical Telescope (FAST) is a radio telescope in China's Guizhou Province. When it is completed in September, it will be the world's second largest radio telescope, with a diameter of 500m.The largest telescope is the operating Russian RATAN-600, with a diameter of 576m. The image was acquired April 14, 2013, covers an area of 6.2 by 8.2 km, and is located at 25.7 degrees north, 106.9 degrees east. http://photojournal.jpl.nasa.gov/catalog/PIA20986

  8. The implementation of education for sustainable development in Sweden: investigating the sustainability consciousness among upper secondary students

    NASA Astrophysics Data System (ADS)

    Berglund, Teresa; Gericke, Niklas; Rundgren, Shu-Nu Chang

    2014-09-01

    Background: Sustainable development (SD) is a complex idea, based on environmental, economic and social dimensions. In line with SD, education for sustainable development (ESD) is an approach to teaching that combines cognitive and affective domains and aims to build empowerment abilities. Purpose: The purpose of this article is to investigate effects of the implementation of ESD in Sweden, in terms of developing students' sustainability consciousness (SC). Two groups of students were included: one was from schools with a profile of ESD and the other one was from comparable schools without explicit ESD-profile. Sample: A total of 638 students from upper secondary schools (grade 12) in science-related or social science-related programs participated in the study. Design and methods: A procedure was created for the selection of schools considered to be the most active in using an ESD approach as well as comparable schools with no explicit ESD approach. During spring 2013, the students responded to a questionnaire based on sustainability knowingness, attitudes and behaviors within the environmental, economic and social dimensions of SD that together constitute the concept of SC. Data were analyzed using SPSS software. Results: The results indicate that there are significant differences in SC between students from schools that teach with an ESD approach compared to students from regular schools. Furthermore, a significant difference between the two groups of students was found in the underlying economic dimension of SC. No significant differences were found in the environmental and social dimensions of SC. Conclusions: Although the results show that ESD-profiled schools have effect on students' SC, the effects are relatively small. Therefore, the effects and nature of the implementation of ESD are discussed.

  9. The efficacy of endoscopic submucosal dissection for colorectal tumors extending to the dentate line.

    PubMed

    Matsumoto, Satohiro; Mashima, Hirosato

    2017-06-01

    Although endoscopic submucosal dissection (ESD) is becoming the mainstay of the treatment strategies, rather than surgical treatment, for colorectal tumors extending to the dentate line, ESD is technically more difficult. This study was aimed at assessing the usefulness of ESD for the treatment of colorectal tumors extending to the dentate line. This study included 531 patients with colorectal tumors who underwent colorectal ESD between 2008 and 2015. They were divided into three groups: rectal tumors extending to the dentate line (anorectal group), those not extending to the dentate line (proximal rectal group), and colonic tumors (colonic group), and a retrospective comparative analysis was carried out. Of the total patients, 18 (3.4%) had lesions extending to the dentate line area. The procedure times were 103.4 ± 84.0, 80.4 ± 64.3, and 71.8 ± 52.3 min, respectively (P = 0.0318). All the patients in the anorectal group were operated by operators who had performed at least 20 colorectal ESDs (P < 0.0001). No significant difference among the three groups was found in the en bloc resection rate, complete resection rate, or curative resection rate. Although no significant difference in the incidence of perforation was observed among the three groups, intraoperative bleeding was observed in 61% of the patients in the anorectal group (P < 0.0001). ESD is an effective treatment strategy for colorectal tumors extending to the dentate line. However, it seems that anorectal ESD, which is technically more difficult than colorectal ESD, should be performed by operators with ample experience in performing ESD.

  10. Time trend of medical economic outcomes of endoscopic submucosal dissection for gastric cancer in Japan: a national database analysis.

    PubMed

    Murata, Atsuhiko; Okamoto, Kohji; Muramatsu, Keiji; Matsuda, Shinya

    2014-04-01

    Little information is available on the analysis of chronological changes in medical economic outcomes of endoscopic submucosal dissection (ESD) for gastric cancer. This study aimed to investigate the recent time trend of medical economic outcomes of ESD for gastric cancer based on the Japanese administrative database. A total of 32,943 patients treated with ESD for gastric cancer were referred to 907 hospitals from 2009 to 2011 in Japan. We collected patients' data from the administrative database to compare ESD-related complications, risk-adjusted length of stay (LOS), and medical costs during hospitalization. The study periods were categorized into three groups: 2009 (n = 9,727), 2010 (n = 11,052), and 2011 (n = 12,164). No significant difference was observed in ESD-related complications between three study periods (p = 0.496). However, mean LOS and medical costs during hospitalization of patients with ESD were significantly lower in 2011 than in 2009 and 2010 (p < 0.001). Multiple linear regression analysis showed that patients who received ESD in 2011 had a significantly shorter LOS and lower medical costs during hospitalization compared with those in 2009. The unstandardized coefficient of patients with ESD in 2011 for LOS was -0.78 days [95 % confidence interval (CI), -0.89 to -0.65; p ≤ 0.001], while that of those for medical costs during hospitalization was -290.5 US dollars (95 % CI, -392.3 to -188.8; p ≤ 0.001). This study showed that the complication rate of ESD was stable, whereas the LOS and medical costs of patients were significantly reduced from 2009 to 2011.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kercel, S.W.; Baylor, V.M.; Labaj, L.E.

    Enclosed Space Detection System (ESDS) is a fast, inexpensive, and reliable device for detecting human occupants hidden in vehicles. Operation requires less than two minutes. ESDS is used to foil attempts at smuggling illegal aliens, terrorists, and escaping prisoners. It is being tested at nuclear weapons facilities and has been operated at several prisons and international border crossings. ESDS is the first practical electronic alternative to physical searches of vehicles for hidden passengers. At critical checkpoints, a thorough physical search of a single fully loaded truck requires a team of from two to six people, and may take as longmore » as eight hours. Despite this level of security, experience has shown that the search can occasionally be foiled. Due to the enormous time and expense of thorough physical searches of vehicles, they are seldom conducted at any but the most critical of locations, simply leaving many sites vulnerable to crime and terrorism. Prior to the development of the ESDS, the only other effective alternative to physical search was the use of specially-trained canines, which can be vastly superior to the physical search in both time and accuracy. However, as discussed in this paper, canine inspection is not really a competitive substitute for ESDS because canine reliability (80% at most) is not as high as that of the ESDS (99%+), while the costs, training requirements, and operator skill needed are significantly higher with canines than with the ESDS. In addition, the ESDS has straightforward self-diagnostic tests to ensure the system is operating correctly; such tests are not currently available with either canine or human inspectors. ESDS offers an attractive supplement or alternative to meet current security requirements for vehicle searches at portals at government, nuclear, industrial, and other facilities where concealed persons may pose a threat either by entering or leaving.« less

  12. Energy-selective SESD imaging utilizing a CMA. [Scanning Electron Stimulated Desorption with Cylindrical Mirror Analyzer

    NASA Technical Reports Server (NTRS)

    Larson, L. A.; Soria, F.; Poppa, H.

    1980-01-01

    A particularly simple conversion of a scanning Auger system for ESD ion energy distributions and scanning ESD has been developed. This approach combines the advantages of the small spot-size electron guns and mapping systems developed for SAM with the capability of ESD for the detection of hydrogen. Our intended use for the device is detection and mapping of surface concentrations of hydrogen on metals. The characteristics of SESD are illustrated with the preliminary results of an investigation into the ESD properties of hydrogenic adsorbates on Nb. It is shown that the ESDIED exhibit distinct differences indicative of the surface preparation, and that the ESD ion angular distributions have an effect on the observed contrast relationships in SESD.

  13. An experimental investigation of the effect of walls on gas-liquid flows through fixed particle beds.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cooper, Marcia A.; Cote, Raymond O.; Torczynski, John Robert

    The effect of particle diameter on downward co-current gas-liquid flow through a fixed bed of particles confined within a cylindrical column is investigated. Several hydrodynamic regimes that depend strongly on the properties of the gas stream, the liquid stream, and the packed particle bed are known to exist within these systems. This experimental study focuses on characterizing the effect of wall confinement on these hydrodynamic regimes as the diameter d of the spherical particles becomes comparable to the column diameter D (or D/d becomes order-unity). The packed bed consists of polished, solid, spherical, monodisperse particles (beads) with mean diameter inmore » the range of 0.64-2.54 cm. These diameters yield D/d values between 15 and 3.75, so this range overlaps and extends the previously investigated range for two-phase flow, Measurements of the pressure drop across the bed and across the pulses are obtained for varying gas and liquid flow rates.« less

  14. [Estimation of Maximum Entrance Skin Dose during Cerebral Angiography].

    PubMed

    Kawauchi, Satoru; Moritake, Takashi; Hayakawa, Mikito; Hamada, Yusuke; Sakuma, Hideyuki; Yoda, Shogo; Satoh, Masayuki; Sun, Lue; Koguchi, Yasuhiro; Akahane, Keiichi; Chida, Koichi; Matsumaru, Yuji

    2015-09-01

    Using radio-photoluminescence glass dosimeter, we measured the entrance skin dose (ESD) in 46 cases and analyzed the correlations between maximum ESD and angiographic parameters [total fluoroscopic time (TFT); number of digital subtraction angiography (DSA) frames, air kerma at the interventional reference point (AK), and dose-area product (DAP)] to estimate the maximum ESD in real time. Mean (± standard deviation) maximum ESD, dose of the right lens, and dose of the left lens were 431.2 ± 135.8 mGy, 33.6 ± 15.5 mGy, and 58.5 ± 35.0 mGy, respectively. Correlation coefficients (r) between maximum ESD and TFT, number of DSA frames, AK, and DAP were r=0.379 (P<0.01), r=0.702 (P<0.001), r=0.825 (P<0.001), and r=0.709 (P<0.001), respectively. AK was identified as the most useful parameter for real-time prediction of maximum ESD. This study should contribute to the development of new diagnostic reference levels in our country.

  15. Clinical features and outcomes of delayed perforation after endoscopic submucosal dissection for early gastric cancer.

    PubMed

    Hanaoka, N; Uedo, N; Ishihara, R; Higashino, K; Takeuchi, Y; Inoue, T; Chatani, R; Hanafusa, M; Tsujii, Y; Kanzaki, H; Kawada, N; Iishi, H; Tatsuta, M; Tomita, Y; Miyashiro, I; Yano, M

    2010-12-01

    Perforation is a major complication of endoscopic submucosal dissection (ESD) for early gastric cancer (EGC). However, there have been no reports on delayed perforation after ESD for EGC. We aimed to elucidate the incidence and outcomes of delayed perforation after ESD. Clinical courses in 1159 consecutive patients with 1329 EGCs who underwent ESD were investigated. Delayed perforation occurred in six patients (0.45 %). All these patients had complete en bloc resection without intraoperative perforation during ESD. Five of six perforations were located in the upper third of the stomach, while one lesion was found in the middle third. Symptoms of peritoneal irritation with rebound tenderness presented within 24 h after ESD in all cases. One patient did not require surgery because the symptoms were localized, and recovered with conservative antibiotic therapy by nasogastric tube placement. The remaining five patients required emergency surgery. There was no mortality in this case series. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Effects of electrostatic discharge on three cryogenic temperature sensor models

    NASA Astrophysics Data System (ADS)

    Courts, S. Scott; Mott, Thomas B.

    2014-01-01

    Cryogenic temperature sensors are not usually thought of as electrostatic discharge (ESD) sensitive devices. However, the most common cryogenic thermometers in use today are thermally sensitive diodes or resistors - both electronic devices in their base form. As such, they are sensitive to ESD at some level above which either catastrophic or latent damage can occur. Instituting an ESD program for safe handling and installation of the sensor is costly and it is desirable to balance the risk of ESD damage against this cost. However, this risk cannot be evaluated without specific knowledge of the ESD vulnerability of the devices in question. This work examines three types of cryogenic temperature sensors for ESD sensitivity - silicon diodes, Cernox{trade mark, serif} resistors, and wire wound platinum resistors, all manufactured by Lake Shore Cryotronics, Inc. Testing was performed per TIA/EIA FOTP129 (Human Body Model). Damage was found to occur in the silicon diode sensors at discharge levels of 1,500 V. For Cernox{trade mark, serif} temperature sensors, damage was observed at 3,500 V. The platinum temperature sensors were not damaged by ESD exposure levels of 9,900 V. At the lower damage limit, both the silicon diode and the Cernox{trade mark, serif} temperature sensors showed relatively small calibration shifts of 1 to 3 K at room temperature. The diode sensors were stable with time and thermal cycling, but the long term stability of the Cernox{trade mark, serif} sensors was degraded. Catastrophic failure occurred at higher levels of ESD exposure.

  17. Entrance surface dose measurements using a small OSL dosimeter with a computed tomography scanner having 320 rows of detectors.

    PubMed

    Takegami, Kazuki; Hayashi, Hiroaki; Yamada, Kenji; Mihara, Yoshiki; Kimoto, Natsumi; Kanazawa, Yuki; Higashino, Kousaku; Yamashita, Kazuta; Hayashi, Fumio; Okazaki, Tohru; Hashizume, Takuya; Kobayashi, Ikuo

    2017-03-01

    Entrance surface dose (ESD) measurements are important in X-ray computed tomography (CT) for examination, but in clinical settings it is difficult to measure ESDs because of a lack of suitable dosimeters. We focus on the capability of a small optically stimulated luminescence (OSL) dosimeter. The aim of this study is to propose a practical method for using an OSL dosimeter to measure the ESD when performing a CT examination. The small OSL dosimeter has an outer width of 10 mm; it is assumed that a partial dose may be measured because the slice thickness and helical pitch can be set to various values. To verify our method, we used a CT scanner having 320 rows of detectors and checked the consistencies of the ESDs measured using OSL dosimeters by comparing them with those measured using Gafchromic™ films. The films were calibrated using an ionization chamber on the basis of half-value layer estimation. On the other hand, the OSL dosimeter was appropriately calibrated using a practical calibration curve previously proposed by our group. The ESDs measured using the OSL dosimeters were in good agreement with the reference ESDs from the Gafchromic™ films. Using these data, we also estimated the uncertainty of ESDs measured with small OSL dosimeters. We concluded that a small OSL dosimeter can be considered suitable for measuring the ESD with an uncertainty of 30 % during CT examinations in which pitch factors below 1.000 are applied.

  18. Can ESD Reach the Year 2020?

    ERIC Educational Resources Information Center

    Lenglet, Frans

    2014-01-01

    In order to have long-term impact ESD concepts, practices and policies should move into societal, policy and research arenas with high visibility and traction. In the process of going "transboundary", the ESD label may fade but the practice and organization of social and collaborative learning may gain.

  19. Effect of egg storage duration and brooding temperatures on chick growth, intestine morphology and nutrient transporters.

    PubMed

    Yalcin, S; Gursel, I; Bilgen, G; Horuluoglu, B H; Gucluer, G; Izzetoglu, G T

    2017-10-01

    The effects of egg storage duration (ESD) and brooding temperature (BT) on BW, intestine development and nutrient transporters of broiler chicks were investigated. A total of 396 chicks obtained from eggs stored at 18°C for 3 days (ESD3-18°C) or at 14°C for 14 days (ESD14-14°C) before incubation were exposed to three BTs. Temperatures were initially set at 32°C, 34°C and 30°C for control (BT-Cont), high (BT-High) and low (BT-Low) BTs, respectively. Brooding temperatures were decreased by 2°C each at days 2, 7, 14 and 21. Body weight was measured at the day of hatch, 2, 7, 14, 21, 28 and 42. Cloacal temperatures of broilers were recorded from 1 to 14 days. Intestinal morphology and gene expression levels of H+-dependent peptide transporter (PepT1) and Na-dependent glucose (SGLT1) were evaluated on the day of hatch and 14. Cloacal temperatures of chicks were affected by BTs from days 1 to 8, being the lowest for BT-Low chicks. BT-High resulted in the heaviest BWs at 7 days, especially for ESD14-14°C chicks. This result was consistent with longer villus and larger villus area of ESD14-14°C chicks at BT-High conditions. From 14 days to slaughter age, BT had no effect on broiler weight. ESD3-18°C chicks were heavier than ESD14-14°C chicks up to 28 days. The PepT1 and SGLT1 expression levels were significantly higher in ESD3-18°C chicks than ESD14-14°C on the day of hatch. There was significant egg storage by BT interaction for PepT1 and SGLT1 transporters at day 14. ESD14-14°C chicks had significantly higher expression of PepT1 and SGLT1 at BT-Low than those at BT-Cont. ESD14-14°C chicks upregulated PepT1 gene expression 1.15 and 1.57-fold at BT-High and BT-Low, respectively, compared with BT-Cont, whereas PepT1 expression was downregulated 0.67 and 0.62-fold in ESD3-18°C chicks at BT-High and BT-Low. These results indicated that pre-incubation egg storage conditions and BTs affected intestine morphology and PepT1 and SGLT1 nutrient transporters expression in broiler chicks.

  20. Moving beyond the EE and ESD Disciplinary Debate in Formal Education

    ERIC Educational Resources Information Center

    McKeown, Rosalyn; Hopkins, Charles

    2007-01-01

    Many educators think of Education for Sustainable Development (ESD) on a disciplinary level--what is Environmental Education's (EE) contribution to a more sustainable future? Briefly, we describe differences and similarities between EE and ESD. Next, we examine four levels of activity--disciplinary, whole school, educational system, and…

  1. Military Handbook: Electrostatic Discharge Control Handbook for Protection of Electrical and Electronic Parts, Assemblies and Equipment (Excluding Electrically Initiated Explosive Devices (Metric)

    DTIC Science & Technology

    1994-07-31

    everything that is received in ESD protective packaging materials treated as ESDS? YES/NO 40.1.13 Is the use of personal hygiene products , food, drinks...Does the training explain why food, drinks, smoking, personal hygiene products or common plastics are not to be used in ESD protective work areas? YES...trays? YES/NO 40.5.13 Are drinking, eating, smoking, the use of personal hygiene products and common plastics prohibited in the ESD protected work area

  2. Education for Sustainable Development and retention: unravelling a research agenda

    NASA Astrophysics Data System (ADS)

    Lotz-Sisitka, Heila

    2010-06-01

    This paper considers the question of what education for sustainable development (ESD) research might signify when linked to the concept of "retention", and how this relation (ESD and retention) might be researched. It considers two different perspectives on retention, as revealed through educational research trajectories, drawing on existing research and case studies. Firstly, it discusses an ESD research agenda that documents retention by focusing on the issue of keeping children in schools. This research agenda is typical of the existing discourses surrounding Education for All (EFA). It then discusses a related ESD research agenda that focuses more on the pedagogical and curricular aspects of retention, as this provides for a deeper understanding of how ESD can contribute to improving the quality of teaching and learning within a wider EFA retention agenda.

  3. Longevity enhances selection of environmental sex determination.

    PubMed

    Bull, J J; Bulmer, M G

    1989-12-01

    Environmental sex determination (ESD) is a mechanism in which an individual develops as male or female largely in response to some environmental effect experienced early in life. Its forms range from sex determination by egg incubation temperature in reptiles to sex determination of photoperiod in amphipods. Previous theoretical work as suggested that ESD is favored by natural selection if the fitness consequences of the early environmental experience differ for males and females, so that an individual benefits by being male under some conditions and female under others. A drawback of ESD is that it enables climatic changes to influence the population sex ratio, and such fluctuations select against ESD. This study employed numerical analyses to investigate the balance between these two opposing forces. The negative impact of climatic fluctuations appears to depend greatly on species longevity: substantial between-year fluctuations are of little consequence in selecting against ESD in long-lived species because annual sex ratio fluctuations tend to cancel and thus alter the total population sex ratio only slightly. Thus, if a species is sufficiently long-lived, extreme ESD can be maintained despite only a weak advantage. This result offers one explanation for the failure to demonstrate an advantage for the extreme forms of ESD observed in reptiles.

  4. Methodology to model the energy and greenhouse gas emissions of electronic software distributions.

    PubMed

    Williams, Daniel R; Tang, Yinshan

    2012-01-17

    A new electronic software distribution (ESD) life cycle analysis (LCA) methodology and model structure were constructed to calculate energy consumption and greenhouse gas (GHG) emissions. In order to counteract the use of high level, top-down modeling efforts, and to increase result accuracy, a focus upon device details and data routes was taken. In order to compare ESD to a relevant physical distribution alternative, physical model boundaries and variables were described. The methodology was compiled from the analysis and operational data of a major online store which provides ESD and physical distribution options. The ESD method included the calculation of power consumption of data center server and networking devices. An in-depth method to calculate server efficiency and utilization was also included to account for virtualization and server efficiency features. Internet transfer power consumption was analyzed taking into account the number of data hops and networking devices used. The power consumed by online browsing and downloading was also factored into the model. The embedded CO(2)e of server and networking devices was proportioned to each ESD process. Three U.K.-based ESD scenarios were analyzed using the model which revealed potential CO(2)e savings of 83% when ESD was used over physical distribution. Results also highlighted the importance of server efficiency and utilization methods.

  5. Safety and efficacy of endoscopic submucosal dissection using IT knife nano with clip traction method for early esophageal squamous cell carcinoma.

    PubMed

    Kitagawa, Yoshiyasu; Suzuki, Takuto; Hara, Taro; Yamaguchi, Taketo

    2018-01-01

    Although endoscopic submucosal dissection (ESD) is an accepted and established treatment for early esophageal squamous cell carcinoma (EESCC), it is technically difficult, time consuming, and less safe than endoscopic mucosal resection. To perform ESD safely and more efficiently, we proposed a new technique of esophageal ESD using an IT knife nano with the clip traction method. This study aimed to evaluate the efficacy and safety of ESD using this new technique. We retrospectively reviewed all consecutive cases of esophageal ESD performed using an IT knife nano with the clip traction method at our hospital between March 2013 and January 2017. Therapeutic efficacy and safety were also assessed. A total of 103 patients underwent esophageal ESD using the IT knife nano with the clip traction method. In all cases, we performed en bloc resection. Complete resection was achieved in 100 cases (97.1%). The median operating time was 40 (range 13-230) min. No cases of perforation or delayed bleeding occurred. Although two cases (2.0%) of mediastinal emphysema occurred without visible perforation at endoscopy, all were successfully managed conservatively. The new technique of esophageal ESD using the IT knife nano with the clip traction method appears to be feasible, effective, and safe for EESCC treatment.

  6. Avian influenza a virus budding morphology: spherical or filamentous?

    USDA-ARS?s Scientific Manuscript database

    Most strains of influenza A virus (IAV) can produce long (µm length) filamentous virus particles as well as ~100 nm diameter spherical virions. The function of the filamentous particles is unclear but is hypothesized to facilitate transmission within or from the respiratory tract. In mammalian IAVs,...

  7. Spherical shock-wave propagation in three-dimensional granular packings.

    PubMed

    Xue, Kun; Bai, Chun-Hua

    2011-02-01

    We investigate numerically the spherical shock-wave propagation in an open dense granular packing perturbed by the sudden expansion of a spherical intruder in the interior of the pack, focusing on the correlation between geometrical fabrics and propagating properties. The measurements of the temporal and spatial variations in a variety of propagating properties define a consistent serrated wave substructure with characteristic length on the orders of particle diameters. Further inspection of particle packing reveals a well-defined particle layering that persists several particle diameters away from the intruder, although its dominant effects are only within one to two diameters. This interface-induced layering not only exactly coincides with the serrated wave profile, but also highlights the competition between two energy transmission mechanisms involving distinct transport speeds. The alternating dominances between these two mechanisms contribute to the nonlinear wave propagation on the particle scale. Moreover, the proliferation of intricate three-dimensional contact force networks suggests the anisotropic stress transmission, which is found to also arise from the localized packing structure in the vicinity of the intruder.

  8. [Halos and multifocal intraocular lenses: origin and interpretation].

    PubMed

    Alba-Bueno, F; Vega, F; Millán, M S

    2014-10-01

    To present the theoretical and experimental characterization of the halo in multifocal intraocular lenses (MIOL). The origin of the halo in a MIOL is the overlaying of 2 or more images. Using geometrical optics, it can be demonstrated that the diameter of each halo depends on the addition of the lens (ΔP), the base power (P(d)), and the diameter of the IOL that contributes to the «non-focused» focus. In the image plane that corresponds to the distance focus, the halo diameter (δH(d)) is given by: δH(d)=d(pn) ΔP/P(d), where d(pn) is the diameter of the IOL that contributes to the near focus. Analogously, in the near image plane the halo diameter (δH(n)) is: δH(n)=d(pd) ΔP/P(d), where d(pd) is the diameter of the IOL that contributes to the distance focus. Patients perceive halos when they see bright objects over a relatively dark background. In vitro, the halo can be characterized by analyzing the intensity profile of the image of a pinhole that is focused by each of the foci of a MIOL. A comparison has been made between the halos induced by different MIOL of the same base power (20D) in an optical bench. As predicted by theory, the larger the addition of the MIOL, the larger the halo diameter. For large pupils and with MIOL with similar aspheric designs and addition (SN6AD3 vs ZMA00), the apodized MIOL has a smaller halo diameter than a non-apodized one in distance vision, while in near vision the size is very similar, but the relative intensity is higher in the apodized MIOL. When comparing lenses with the same diffractive design, but with different spherical-aspheric base design (SN60D3 vs SN6AD3), the halo in distance vision of the spherical MIOL is larger, while in near vision the spherical IOL induces a smaller halo, but with higher intensity due to the spherical aberration of the distance focus in the near image. In the case of a trifocal-diffractive IOL (AT LISA 839MP) the most noticeable characteristic is the double-halo formation due to the 2 non-focused powers. Copyright © 2013 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  9. A multiball read-out for the spherical proportional counter

    NASA Astrophysics Data System (ADS)

    Giganon, A.; Giomataris, I.; Gros, M.; Katsioulas, I.; Navick, X. F.; Tsiledakis, G.; Savvidis, I.; Dastgheibi-Fard, A.; Brossard, A.

    2017-12-01

    We present a novel concept of proportional gas amplification for the read-out of the spherical proportional counter. The standard single-ball read-out presents limitations for large diameter spherical detectors and high-pressure operations. We have developed a multi-ball read-out system which consists of several balls placed at a fixed distance from the center of the spherical vessel. Such a module can tune the volume electric field at the desired value and can also provide detector segmentation with individual ball read-out. In the latter case, the large volume of the vessel becomes a spherical time projection chamber with 3D capabilities.

  10. Apparatus for irradiating a continuously flowing stream of fluid. [For neutron activation analysis

    DOEpatents

    Speir, L.G.; Adams, E.L.

    1982-05-13

    An apparatus for irradiating a continuously flowing stream of fluid is disclosed. The apparatus consists of a housing having a spherical cavity and a spherical moderator containing a radiation source positioned within the spherical cavity. The spherical moderator is of lesser diameter than the spherical cavity so as to define a spherical annular volume around the moderator. The housing includes fluid intake and output conduits which open onto the spherical cavity at diametrically opposite positions. Fluid flows through the cavity around the spherical moderator and is uniformly irradiated due to the 4..pi.. radiation geometry. The irradiation source, for example a /sup 252/Cf neutron source, is removable from the spherical moderator through a radial bore which extends outwardly to an opening on the outside of the housing. The radiation source may be routinely removed without interrupting the flow of fluid or breaching the containment of the fluid.

  11. Apparatus for irradiating a continuously flowing stream of fluid

    DOEpatents

    Speir, Leslie G.; Adams, Edwin L.

    1984-01-01

    An apparatus for irradiating a continuously flowing stream of fluid is diosed. The apparatus consists of a housing having a spherical cavity and a spherical moderator containing a radiation source positioned within the spherical cavity. The spherical moderator is of lesser diameter than the spherical cavity so as to define a spherical annular volume around the moderator. The housing includes fluid intake and output conduits which open onto the spherical cavity at diametrically opposite positions. Fluid flows through the cavity around the spherical moderator and is uniformly irradiated due to the 4.pi. radiation geometry. The irradiation source, for example a .sup.252 CF neutron source, is removable from the spherical moderator through a radial bore which extends outwardly to an opening on the outside of the housing. The radiation source may be routinely removed without interrupting the flow of fluid or breaching the containment of the fluid.

  12. Proper muscle layer damage affects ulcer healing after gastric endoscopic submucosal dissection.

    PubMed

    Horikawa, Yohei; Mimori, Nobuya; Mizutamari, Hiroya; Kato, Yuhei; Shimazu, Kazuhiro; Sawaguchi, Masayuki; Tawaraya, Shin; Igarashi, Kimihiro; Okubo, Syunji

    2015-11-01

    Endoscopic submucosal dissection (ESD) is the established therapy for superficial gastrointestinal neoplasms. However, management of the artificial ulcers associated with ESD has become important and the relationship between ulcer healing factors and treatment is still unclear. We aimed to evaluate ESD-related artificial ulcer reduction ratio at 4 weeks to assess factors associating with ulcer healing after ESD that may lead to optimal treatment. Between January 2009 and December 2013, a total of 375 lesions fulfilled the expanded criteria for ESD. We defined ulcer reduction rate <90% as (A) poor-healing group; and rate ≥90% as (B) well-healing group. After exclusion, 328 lesions were divided into two groups and analyzed. These two groups were compared based on clinicopathological/endoscopic features, concomitant drugs, and treatment. Ulcer reduction rate was significantly correlated with factors related to the ESD procedure (i.e. procedure time, submucosal fibrosis, and injury of the proper muscle layer, in univariate analysis. Multivariate logistic regression analysis showed that submucosal fibrosis (F2) (P = 0.03; OR, 16.46; 95% CI, 1.31-206.73) and injury of the proper muscle layer (P = 0.01; OR, 4.27; 95% CI, 2.04-8.92) were statistically significant predictors of delayed healing. This single-center retrospective study indicated that ESD-induced artificial ulcer healing was affected by submucosal fibrosis and injury of the proper muscle layer, which induced damage to the muscle layer. Therefore, the preferable pharmacotherapy can be determined on completion of the ESD procedure. © 2015 The Authors Digestive Endoscopy © 2015 Japan Gastroenterological Endoscopy Society.

  13. Nuclear artifacts in gastric endoscopic submucosal dissection specimens: A clinicopathological study

    PubMed Central

    MATSUKUMA, SUSUMU; TAKEO, HIROAKI; SATO, KIMIYA

    2014-01-01

    To delineate the characteristics of nuclear artifacts associated with endoscopic submucosal dissection (ESD), we examined 97 gastric ESD specimens from 79 patients. In 69 of the specimens (71%), multinucleated figures and/or atypical mitotic-like figures, including tripolar-like and bizarre spindles, were found in the peripheral portions close to the marking areas. These nuclear figures were mostly recognizable as artifacts, but were infrequently (13 specimens) accompanied by other nuclear alterations and/or architectural abnormalities, mimicking dysplasia. However, in the deep cut sections, the dysplastic characteristics tended to disappear and coagulative or degenerative findings became more prominent. These nuclear artifacts were not found in 69 age- and gender-matched control gastrectomy specimens without ESD. Multinucleated artifacts were associated with the size of the ESD specimens (P=0.003), frequency of marking (P<0.001) and a history of ‘previous’ marking 1–6 days prior to ESD (P<0.001); however, they were not associated with age, ESD procedure time, or ‘fresh’ marking on the day of the ESD. Atypical mitosis-like characteristics were associated with a history of ‘fresh’ (P=0.007) as well as ‘previous’ (P=0.002) marking, but not with other variables. Dysplasia-like artifacts were associated with older age only (P=0.031). Follow-up data of all the patients with nuclear artifacts showed no aggressive behavior. Therefore, we concluded that these nuclear changes were ESD-related artifacts. Particularly in older patients, these changes may simulate dysplasia and must be distinguished from true dysplasia or neoplasia. PMID:25054062

  14. Shaping the GAP: Ideas for the UNESCO Post-2014 ESD Agenda

    ERIC Educational Resources Information Center

    Taylor, Jim

    2014-01-01

    This paper explores how ESD activities may be viewed on a continuum from "causal" approaches, seeking to cause change in others, to "enabling" orientations where efforts are made to enable people to implement the principles of ESD and respond to the environmental challenges they face from their own context. An enabling…

  15. Outlook on Research in Education for Sustainable Development

    ERIC Educational Resources Information Center

    Grasel, Cornelia; Bormann, Inka; Schutte, Kerstin; Trempler, Kati; Fischbach, Robert

    2013-01-01

    This article provides an overview of current research on Education for Sustainable Development (ESD). It shows a lack of correspondence between ESD research and recent debates in educational research. Research on ESD has established as a field of research with insufficient relations to other fields in educational research. Based on the overview…

  16. Education for Sustainable Development (ESD): The Turn away from "Environment" in Environmental Education?

    ERIC Educational Resources Information Center

    Kopnina, Helen

    2012-01-01

    This article explores the implications of the shift of environmental education (EE) towards education for sustainable development (ESD) in the context of environmental ethics. While plural perspectives on ESD are encouraged both by practitioners and researchers of EE, there is also a danger that such pluralism may sustain dominant political…

  17. No-Self, Natural Sustainability and Education for Sustainable Development

    ERIC Educational Resources Information Center

    Wang, Chia-Ling

    2017-01-01

    This article explores the significance of sustainability and several ways in which education for sustainable development (ESD) can be considered. It presents several issues related to the theories of sustainability and ESD, which are generated based on a firm concept of anthropocentrism. ESD has been used for developing a scientific understanding…

  18. Challenging the Focus of ESD: A Southern Perspective of ESD Guidelines

    ERIC Educational Resources Information Center

    de Andrade, Daniel Fonseca

    2011-01-01

    In parallel to the 2009 World Conference on Education for Sustainable Development held in Bonn, Germany, UNESCO organised a group of 25 young education for sustainable development (ESD)-engaged people from 25 countries to bring perceptions, demands, suggestions and contributions to the conference. Prior to the conference the group was divided into…

  19. ESD and Education for All: Synergies and Potential Conflicts

    ERIC Educational Resources Information Center

    Gadotti, Moacir

    2010-01-01

    This paper analyses how Education for Sustainable Development (ESD) can assist in increasing access to quality education and discusses how it can contribute to the content and learning methods on the Education for All (EFA) agenda. It explores both the tensions and the common ground between ESD and EFA, and identifies the potential synergies…

  20. Differential Diagnosis of Erythmato-Squamous Diseases Using Classification and Regression Tree.

    PubMed

    Maghooli, Keivan; Langarizadeh, Mostafa; Shahmoradi, Leila; Habibi-Koolaee, Mahdi; Jebraeily, Mohamad; Bouraghi, Hamid

    2016-10-01

    Differential diagnosis of Erythmato-Squamous Diseases (ESD) is a major challenge in the field of dermatology. The ESD diseases are placed into six different classes. Data mining is the process for detection of hidden patterns. In the case of ESD, data mining help us to predict the diseases. Different algorithms were developed for this purpose. we aimed to use the Classification and Regression Tree (CART) to predict differential diagnosis of ESD. we used the Cross Industry Standard Process for Data Mining (CRISP-DM) methodology. For this purpose, the dermatology data set from machine learning repository, UCI was obtained. The Clementine 12.0 software from IBM Company was used for modelling. In order to evaluation of the model we calculate the accuracy, sensitivity and specificity of the model. The proposed model had an accuracy of 94.84% (. 24.42) in order to correct prediction of the ESD disease. Results indicated that using of this classifier could be useful. But, it would be strongly recommended that the combination of machine learning methods could be more useful in terms of prediction of ESD.

  1. Colorectal endoscopic submucosal dissection: Recent technical advances for safe and successful procedures

    PubMed Central

    Yamamoto, Katsumi; Michida, Tomoki; Nishida, Tsutomu; Hayashi, Shiro; Naito, Masafumi; Ito, Toshifumi

    2015-01-01

    Endoscopic submucosal dissection (ESD) is very useful in en bloc resection of large superficial colorectal tumors but is a technically difficult procedure because the colonic wall is thin and endoscopic maneuverability is poor because of colonic flexure and extensibility. A high risk of perforation has been reported in colorectal ESD. To prevent complications such as perforation and unexpected bleeding, it is crucial to ensure good visualization of the submucosal layer by creating a mucosal flap, which is an exfoliated mucosa for inserting the tip of the endoscope under it. The creation of a mucosal flap is often technically difficult; however, various types of equipment, appropriate strategy, and novel procedures including our clip-flap method, appear to facilitate mucosal flap creation, improving the safety and success rate of ESD. Favorable treatment outcomes with colorectal ESD have already been reported in many advanced institutions, and appropriate understanding of techniques and development of training systems are required for world-wide standardization of colorectal ESD. Here, we describe recent technical advances for safe and successful colorectal ESD. PMID:26468335

  2. Gaussian Beam Intensity Flattener

    NASA Technical Reports Server (NTRS)

    Griffin, DeVon W.

    1998-01-01

    The goal of this investigation was to use commercial elements and extend the correction to a 1/e(sup 2) diameter of 3 mm over long propagation distances. Shafer discussed the use of spherical elements to generate a uniform beam to the 1/e diameter.

  3. A study of the initial oxidation of evaporated thin films of aluminum by AES, ELS, and ESD

    NASA Technical Reports Server (NTRS)

    Bujor, M.; Larson, L. A.; Poppa, H.

    1982-01-01

    The room temperature, low pressure, oxidation of evaporated aluminum thin films has been studied by AES, ELS, and ESD. ESD was the most sensitive of the three methods to characterize a clean aluminum surface. Two oxidation stages were distinguished in the 0-3000 L oxygen exposure range. Between 0 and 50 L, the chemisorption of oxygen atoms was characterized by a fast decrease of the 67 eV AES Al peak and the 10 eV surface plasmon peak, and by a simultaneous increase of the oxygen AES and ESD signals. After 50 L, a change in slope in all AES and ESD signal variations was attributed to the slow growth of a thin layer of aluminum oxide, which after 3000 L was still only a few angstroms thick.

  4. Electrostatic Evaluation: SCAPE Suit Materials

    NASA Technical Reports Server (NTRS)

    Buhler, Charles; Calle, Carlos

    2005-01-01

    The surface resistivity tests are performed per the requirements of the ESD Association Standard Test Method ESD STM11.11*. These measurements are taken using a PRS-801 resistance system with an Electro Tech System (ETS) PRF-911 concentric ring resistance probe. The tests require a five pound weight on top of cylindrical electrodes and were conducted at both ambient and low humidity conditions. In order for materials to "pass" resistivity tests the surface of the materials must either be conductive or statically dissipative otherwise the materials "fail" ESD. Volume resistivity tests are also conducted to measure conductivity through the material as opposed to conductivity along the surface. These tests are conducted using the same PRS-801 resistance system with the Electro Tech System PRF-911 concentric ring resistance probe but are performed in accordance with ESD Association Standard Test Method ESD STM11.l2**.

  5. Ecological and morphological profile of floating spherical Cladophora socialis aggregations in central Thailand.

    PubMed

    Tsutsui, Isao; Miyoshi, Tatsuo; Sukchai, Halethichanok; Pinphoo, Piyarat; Aue-Umneoy, Dusit; Meeanan, Chonlada; Songphatkaew, Jaruwan; Klomkling, Sirimas; Yamaguchi, Iori; Ganmanee, Monthon; Sudo, Hiroyuki; Hamano, Kaoru

    2015-01-01

    The unique beauty of spherical aggregation forming algae has attracted much attention from both the scientific and lay communities. Several aegagropilous seaweeds have been identified to date, including the plants of genus Cladophora and Chaetomorpha. However, this phenomenon remains poorly understood. In July 2013, a mass occurrence of spherical Cladophora aggregations was observed in a salt field reservoir in Central Thailand. The aims of the present study were to describe the habitat of the spherical aggregations and confirm the species. We performed a field survey, internal and external morphological observations, pyrenoid ultrastructure observations, and molecular sequence analysis. Floating spherical Cladophora aggregations (1-8 cm in diameter) were observed in an area ~560 m2, on the downwind side of the reservoir where there was water movement. Individual filaments in the aggregations were entangled in each other; consequently, branches growing in different directions were observed within a clump. We suggest that water movement and morphological characteristics promote the formation of spherical aggregations in this species. The molecular sequencing results revealed that the study species was highly homologous to both C. socialis and C. coelothrix. However, the diameter of the apical cells in the study species was less than that of C. coelothrix. The pyrenoid ultrastructure was more consistent with that of C. socialis. We conclude that the study species is C. socialis. This first record of spherical aggregations in this species advances our understanding of these formations. However, further detailed physical measurements are required to fully elucidate the mechanism behind these spherical formations.

  6. Ecological and Morphological Profile of Floating Spherical Cladophora socialis Aggregations in Central Thailand

    PubMed Central

    Tsutsui, Isao; Miyoshi, Tatsuo; Sukchai, Halethichanok; Pinphoo, Piyarat; Aue-umneoy, Dusit; Meeanan, Chonlada; Songphatkaew, Jaruwan; Klomkling, Sirimas; Yamaguchi, Iori; Ganmanee, Monthon; Sudo, Hiroyuki; Hamano, Kaoru

    2015-01-01

    The unique beauty of spherical aggregation forming algae has attracted much attention from both the scientific and lay communities. Several aegagropilous seaweeds have been identified to date, including the plants of genus Cladophora and Chaetomorpha. However, this phenomenon remains poorly understood. In July 2013, a mass occurrence of spherical Cladophora aggregations was observed in a salt field reservoir in Central Thailand. The aims of the present study were to describe the habitat of the spherical aggregations and confirm the species. We performed a field survey, internal and external morphological observations, pyrenoid ultrastructure observations, and molecular sequence analysis. Floating spherical Cladophora aggregations (1–8 cm in diameter) were observed in an area ~560 m2, on the downwind side of the reservoir where there was water movement. Individual filaments in the aggregations were entangled in each other; consequently, branches growing in different directions were observed within a clump. We suggest that water movement and morphological characteristics promote the formation of spherical aggregations in this species. The molecular sequencing results revealed that the study species was highly homologous to both C. socialis and C. coelothrix. However, the diameter of the apical cells in the study species was less than that of C. coelothrix. The pyrenoid ultrastructure was more consistent with that of C. socialis. We conclude that the study species is C. socialis. This first record of spherical aggregations in this species advances our understanding of these formations. However, further detailed physical measurements are required to fully elucidate the mechanism behind these spherical formations. PMID:25898393

  7. ESD testing of the 8S actuator (u)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mchugh, Douglas C

    2010-12-03

    The 8S actuator is a hot-wire initiated explosive component used to drive the W76-1 2X Acorn 1V valve. It is known to be safe from human electrostatic discharge (ESD) pin-to-pin and all pin-to-cup stimuli as well as 1 amp/1 watt safe. However low impedance (furniture) ESD stimuli applied pin-to-pin has not been evaluated. Components were tested and the results analyzed. The 8S actuator has been shown to be immune to human and severe furniture ESD, whether applied pin-to-pin or pin-to-cup.

  8. Imaging indicator for ESD safety testing.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whinnery, LeRoy L.,; Nissen, April; Keifer, Patrick N.

    2013-05-01

    This report describes the development of a new detection method for electrostatic discharge (ESD) testing of explosives, using a single-lens reflex (SLR) digital camera and a 200-mm macro lens. This method has demonstrated several distinct advantages to other current ESD detection methods, including the creation of a permanent record, an enlarged image for real-time viewing as well as extended periods of review, and ability to combine with most other Go/No-Go sensors. This report includes details of the method, including camera settings and position, and results with wellcharacterized explosives PETN and RDX, and two ESD-sensitive aluminum powders.

  9. Precordial skin burns after endoscopic submucosal dissection for gastric tube cancer.

    PubMed

    Miyagi, Motoshi; Yoshio, Toshiyuki; Hirasawa, Toshiaki; Ishiyama, Akiyoshi; Yamamoto, Yorimasa; Tsuchida, Tomohiro; Fujisaki, Junko; Igarashi, Masahiro

    2015-11-01

    Endoscopic submucosal dissection (ESD) is useful as a minimally invasive treatment option for early gastric cancer. ESD is also used in the management of postoperative remnant gastric cancers in the stomach and gastric tube cancers. Perforation and delayed bleeding have been the main complications of ESD reported in the management of gastric tube cancer. However, in the current literature, there is no description of precordial skin burns caused by electrical coagulation. While we treated 22 patients with gastric tube cancers by ESD from 2005 to 2014, we experienced five skin burns in four patients after ESD. We retrospectively analyzed clinical characteristics of precordial skin burn as a complication of ESD. All skin burns occurred in patients reconstructed using a presternal route, whose incidence of precordial skin burn was 55.6%. In all cases, lesions were located in the upper or middle third of gastric tubes irrespective of their direction. Skin burn developed on postoperative day (POD) 1 or POD 2, taking 4-7 days to heal and was accompanied by high fever in 60% of cases. The present study suggests that when carrying out ESD for gastric tube cancer using the presternal route, it is necessary to consider the occurrence of a precordial skin burn as a possible complication. © 2015 The Authors. Digestive Endoscopy © 2015 Japan Gastroenterological Endoscopy Society.

  10. Migratory life histories explain the extreme egg-size dimorphism of Eudyptes penguins

    PubMed Central

    Williams, Tony D.

    2016-01-01

    When successive stages in the life history of an animal directly overlap, physiological conflicts can arise resulting in carryover effects from one stage to another. The extreme egg-size dimorphism (ESD) of Eudyptes penguins, where the first-laid A-egg is approximately 18–57% smaller than the second-laid B-egg, has interested researchers for decades. Recent studies have linked variation in this trait to a carryover effect of migration that limits the physiology of yolk production and egg sizes. We assembled data on ESD and estimates of migration–reproduction overlap in penguin species and use phylogenetic methods to test the idea that migration–reproduction overlap explains variation in ESD. We show that migration overlap is generally restricted to Eudyptes relative to non-Eudyptes penguins, and that this overlap (defined as the amount of time that egg production occurs on land versus at sea during homeward migration) is significantly and positively correlated with the degree of ESD in Eudyptes. In the non-Eudyptes species, however, ESD was unrelated to migration overlap as these species mostly produce their clutches on land. Our results support the recent hypothesis that extreme ESD of Eudyptes penguins evolved, in part, as a response to selection for a pelagic overwinter migration behaviour. This resulted in a temporal overlap with, and thus a constraint on, the physiology of follicle development, leading to smaller A-egg size and greater ESD. PMID:27708146

  11. Understanding the failure mechanisms of microwave bipolar transistors caused by electrostatic discharge

    NASA Astrophysics Data System (ADS)

    Jin, Liu; Yongguang, Chen; Zhiliang, Tan; Jie, Yang; Xijun, Zhang; Zhenxing, Wang

    2011-10-01

    Electrostatic discharge (ESD) phenomena involve both electrical and thermal effects, and a direct electrostatic discharge to an electronic device is one of the most severe threats to component reliability. Therefore, the electrical and thermal stability of multifinger microwave bipolar transistors (BJTs) under ESD conditions has been investigated theoretically and experimentally. 100 samples have been tested for multiple pulses until a failure occurred. Meanwhile, the distributions of electric field, current density and lattice temperature have also been analyzed by use of the two-dimensional device simulation tool Medici. There is a good agreement between the simulated results and failure analysis. In the case of a thermal couple, the avalanche current distribution in the fingers is in general spatially unstable and results in the formation of current crowding effects and crystal defects. The experimental results indicate that a collector-base junction is more sensitive to ESD than an emitter-base junction based on the special device structure. When the ESD level increased to 1.3 kV, the collector-base junction has been burnt out first. The analysis has also demonstrated that ESD failures occur generally by upsetting the breakdown voltage of the dielectric or overheating of the aluminum-silicon eutectic. In addition, fatigue phenomena are observed during ESD testing, with devices that still function after repeated low-intensity ESDs but whose performances have been severely degraded.

  12. Current status of endoscopic submucosal dissection for early gastric cancer in Korea: role and benefits.

    PubMed

    Kim, Sang Gyun; Lyu, Da Hyun; Park, Chan Mi; Lee, Na Rae; Kim, Jiyoung; Cha, Youngju; Jung, Hwoon-Yong

    2018-06-21

    This study was aimed to investigate the current clinical status of endoscopic submucosal dissection (ESD) for early gastric cancer (EGC) in Korea based on a National Health Insurance (NHI) database between 2011 and 2014. The claims data of ESD for EGC in Korean NHI were reviewed using material codes of Health Insurance Review and Assessment Service between November 2011 and December 2014. The current clinical status was analyzed in terms of treatment pattern, in-hospital length of stay (LOS), total medical costs, and en bloc resection rate according to the hospital type. A total of 23,828 cases of ESD for EGC were evaluated. ESD was performed in 67.4% of cases in tertiary care hospitals, 31.8% in general hospitals, and 0.8% in hospitals, respectively. The median LOS was 5 days, and total median medical costs was approximately 1,300 US dollars. En bloc resection rate was 99%; 8.5% of cases underwent additional treatment within 90 days ESD, and 5.5% in 91 to 365 days after ESD. The clinical status was not significantly different according to the year and hospital type. A majority of ESD for EGC were performed in tertiary care hospitals in Korea. The clinical status showed excellent clinical outcomes and did not differ by the year and between the types of hospitals in Korea.

  13. Education for Sustainable Development in German Science Education: Past-Present-Future

    ERIC Educational Resources Information Center

    Bögeholz, Susanne; Böhm, Marko; Eggert, Sabina; Barkmann, Jan

    2013-01-01

    In this paper, we trace selected strands of the German path to Education for Sustainable Development (ESD). We start by addressing pre-ESD research, and move to the concept of "Gestaltungskompetenz," the core concept of German ESD. The concept had to be realigned as to become more compatible with international research on learning…

  14. Education as a Global "Soft Power" for Sustainable Development

    ERIC Educational Resources Information Center

    Sayamov, Yury Nikolayevich

    2013-01-01

    Purpose: The purpose of this paper is to analyse various aspects of education for sustainable development (ESD) drawing attention to the approaching end of the UN Decade on ESD (DESD) in 2014 and to the necessity of the continuation of ESD activities. Defining the internationalisation of education as an ever more significant part of globalisation,…

  15. Examining the Literature to Reveal the Nature of Community EE/ESD Programs and Research

    ERIC Educational Resources Information Center

    Aguilar, Olivia M.

    2018-01-01

    Interest in community environmental education (EE) and community education for sustainable development (ESD) is increasing, as evidenced by the increase in studies examining community EE/ESD approaches and NAAEE's current development of the Community EE Guidelines for Excellence. Thus, the purpose of this paper is to: (1) provide a review of…

  16. Engaging Mindfully with the Commons: A Case of Caribbean Teachers' Experience with ESD

    ERIC Educational Resources Information Center

    Down, Lorna

    2015-01-01

    A study of teachers' responses to Education for Sustainable Development (ESD) in a graduate course in Literature and Education for Sustainable Development, at the School of Education, The University of the West Indies, Mona, revealed that ESD can change indifference to the "commons" to one of mindfulness about local and global…

  17. ESD Professional Development of University Educators in Serbia, Croatia and Macedonia: A Comparative Analysis

    ERIC Educational Resources Information Center

    Nikolic, Vesna; Milutinovic, Slobodan; Nedanovski, Pece; Mrnjaus, Kornelija

    2017-01-01

    Purpose: The paper aims to deal with the education for sustainable development (ESD) competences of university educators. The purpose of this paper is to provide a comparative analysis of opportunities for the development of ESD competences in higher education (HE) institutions in Serbia, Croatia and Macedonia. In addition, the paper explores the…

  18. Current State and Future Prospects of Education for Sustainable Development (ESD) in Japan

    ERIC Educational Resources Information Center

    Tanaka, Haruhiko

    2017-01-01

    The UN Decade of Education for Sustainable Development (ESD) ran from 2005 to 2014. This study concerns the concepts of Sustainable Development (SD) and ESD. The term "sustainable development" was coined by the Brundtland Commission in 1987 as the key word in integrating environment and development. SD achieved international consensus at…

  19. Tracing Sustainability: An International Comparison of ESD Implementation into Lower Secondary Education

    ERIC Educational Resources Information Center

    Bagoly-Simó, Péter

    2013-01-01

    With the progress of the DESD, increasing numbers of researchers have been developing indicators to effectively measure the implementation of ESD in formal, informal and non-formal education. This paper aims to measure the implementation of ESD in secondary school curricula in three countries carrying the fingerprints of a developed (Germany),…

  20. Contributions of Education for Sustainable Development (ESD) to Quality Education: A Synthesis of Research

    ERIC Educational Resources Information Center

    Laurie, Robert; Nonoyama-Tarumi, Yuko; Mckeown, Rosalyn; Hopkins, Charles

    2016-01-01

    This research is a synthesis of studies carried out in 18 countries to identify contributions of education for sustainable development (ESD) to quality education. Five common questions were used for the interviews in each country to solicit education leaders and practitioners' views on the outcome and implementation of ESD. The analysis revealed…

  1. A Case-Control Study of Esomeprazole Plus Rebamipide vs. Omeprazole Plus Rebamipide on Post-ESD Gastric Ulcers.

    PubMed

    Bunno, Maki; Gouda, Kyosuke; Yamahara, Kunihiro; Kawaguchi, Masanori

    2013-01-01

    Endoscopic submucosal dissection (ESD) is useful for treating gastric tumors. Several trials have shown the efficacy of 4 or 8 weeks of proton pump inhibitor (PPI) administration for post-ESD ulcers. However, if the size of the post-ESD ulcer is larger than predicted, PPI administration alone might not be sufficient for the ulcer to heal within 4 weeks. There is no report about the efficacy of post-ESD gastric ulcers by esomeprazole. We examined retrospectively the efficacy of a combination therapy of esomeprazole plus rebamipide, a mucosal-protective antiulcer drug, on the acceleration of post-ESD ulcer healing comparing with omeprazole plus rebamipide. We reviewed the medical records of patients who underwent ESD for gastric neoplasia. We conducted a case-control study to compare the healing rates within 4 weeks effected by esomeprazole plus rebamipide (group E) and omeprazole plus rebamipide (group O). The sizes of the artificial ulcers were divided into normal-sized or large-sized. The baseline characteristics did not differ significantly between the two groups except age and sex. Stage S1 disease was observed in 27.6% and 38.7% of patients after 4 weeks of treatment in the group E and O, respectively. In large-sized artificial ulcers, the healing rate of stage S1 in group E is significantly higher than that in group O in 4 weeks.(25% VS 0%:P = 0.02). The safety and efficacy profiles of esomeprazole plus rebamipide and omeprazole and rebamipide are similar for the treatment of ESD-induced ulcers. In large-sized ulcers, esomeprazole plus rebamipide promotes ulcer healing.

  2. Early Supported Discharge/Hospital At Home For Acute Exacerbation of Chronic Obstructive Pulmonary Disease: A Review and Meta-Analysis.

    PubMed

    Echevarria, Carlos; Brewin, Karen; Horobin, Hazel; Bryant, Andrew; Corbett, Sally; Steer, John; Bourke, Stephen C

    2016-08-01

    A systematic review and meta-analysis was performed to assess the safety, efficacy and cost of Early Supported Discharge (ESD) and Hospital at Home (HAH) compared to Usual Care (UC) for patients with acute exacerbation of COPD (AECOPD). The structure of ESD/HAH schemes was reviewed, and analyses performed assuming return to hospital during the acute period (prior to discharge from home treatment) was, and was not, considered a readmission. The pre-defined search strategy completed in November 2014 included electronic databases (Medline, Embase, Amed, BNI, Cinahl and HMIC), libraries, current trials registers, national organisations, key respiratory journals, key author contact and grey literature. Randomised controlled trials (RCTs) comparing ESD/HAH to UC in patients admitted with AECOPD, or attending the emergency department and triaged for admission, were included. Outcome measures were mortality, all-cause readmissions to 6 months and cost. Eight RCTs were identified; seven reported mortality and readmissions. The structure of ESD/HAH schemes, particularly selection criteria applied and level of support provided, varied considerably. Compared to UC, ESD/HAH showed a trend towards lower mortality (RRMH = 0.66; 95% CI 0.40-1.09, p = 0.10). If return to hospital during the acute period was not considered a readmission, ESD/HAH was associated with fewer readmissions (RRMH = 0.74, 95% CI: 0.60-0.90, p = 0.003), but if considered a readmission, the benefit was lost (RRMH = 0.84; 95% CI 0.69-1.01, p = 0.07). Costs were lower for ESD/HAH than UC. ESD/HAH is safe in selected patients with an AECOPD. Further research is required to define optimal criteria to guide patient selection and models of care.

  3. Age Induced Effects on ESD Characteristics of Solar Array Coupons After Combined Space Environmental Exposures

    NASA Technical Reports Server (NTRS)

    Wright, Kenneth H.; Schneider, Todd A.; Vaughn, Jason A.; Hoang, Bao; Funderburk, Victor V.; Wong, Frankie; Gardiner, George

    2012-01-01

    A set of multi-junction GaAs/Ge solar array test coupons provided by Space Systems/Loral were subjected to a sequence of 5-year increments of combined space environment exposure tests. The test coupons capture an integrated design intended for use in a geosynchronous (GEO) space environment. A key component of this test campaign is performing electrostatic discharge (ESD) tests in the inverted gradient mode. The protocol of the ESD tests is based on the ISO standard for ESD testing on solar array panels [ISO-11221]. The test schematic in the ISO reference has been modified with Space System/Loral designed circuitry to better simulate the on-orbit operational conditions of its solar array design. Part of the modified circuitry is to simulate a solar array panel coverglass flashover discharge. All solar array coupons used in the test campaign consist of four cells constructed to form two strings. The ESD tests were performed at the beginning-of-life (BOL) and at each 5-year environment exposure point until end-of-life (EOL) at 15 years. The space environmental exposure sequence consisted of ultra-violet radiation, electron/proton particle radiation, thermal cycling, and Xenon ion thruster plume erosion. This paper describes the ESD test setup and the importance of the electrical test design in simulating the on-orbit operational conditions. Arc inception voltage results along with ESD test behavior from the BOL condition through the 15th year age condition are discussed. In addition, results from a Xenon plasma plume exposure test with an EOL coupon under the full ESD test condition will be discussed.

  4. A randomized controlled trial of prophylactic antibiotics in the prevention of electrocoagulation syndrome after colorectal endoscopic submucosal dissection.

    PubMed

    Lee, Sang Pyo; Sung, In-Kyung; Kim, Jeong Hwan; Lee, Sun-Young; Park, Hyung Seok; Shim, Chan Sup; Ki, Hyun Kyun

    2017-08-01

    Endoscopic submucosal dissection (ESD) is currently commonly performed, but colorectal ESD has a substantial risk of adverse events, including post-ESD electrocoagulation syndrome (PEECS). We investigated whether the use of prophylactic antibiotics can reduce the occurrence of PEECS. Patients who underwent colorectal ESD were randomly assigned to 1 of 2 treatment regimens. Ampicillin and/or sulbactam mixed with normal saline solution was administered 1 hour before ESD in group 1 then additionally injected every 8 hours twice more. In group 2, normal saline solution without antibiotics was administered following the same schedule. We investigated the characteristics of the patients and tumors, the incidence of PEECS, laboratory findings, and the visual analog scale (VAS) score for abdominal pain measured on the morning after ESD. A total of 100 cases (50 per group) were finally analyzed, and 97 tumors were successfully resected en bloc. The number of patients having C-reactive protein (CRP) levels ≥1 mg/dL and the number of patients having VAS scores for abdominal pain ≥1 were greater in group 2 than in group 1 (P = .008 and .023, respectively). The incidence of PEECS in group 2 also was higher than that in group 1 (1 and 8 in groups 1 and 2, respectively; P = .031). The prophylactic use of ampicillin and/or sulbactam in colorectal ESD is associated with reduced risk of PEECS, decreased CRP levels, and decreased abdominal pain. The use of prophylactic antibiotics in colorectal ESD may be an effective tool for reducing the risk of PEECS. (Clinical trial registration number: KCT0001102.). Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  5. Changes in entrance surface dose in relation to the location of shielding material in chest computed tomography

    NASA Astrophysics Data System (ADS)

    Kang, Y. M.; Cho, J. H.; Kim, S. C.

    2015-07-01

    This study examined the effects of entrance surface dose (ESD) on the abdomen and pelvis of the patient when undergoing chest computed tomography (CT) procedure, and evaluated the effects of ESD reduction depending on the location of radiation shield. For CT scanner, the 64-slice multi-detector computed tomography was used. The alderson radiation therapy phantom and optically stimulated luminescence dosimeter (OSLD), which enabled measurement from low to high dose, were also used. For measurement of radiation dose, the slice number from 9 to 21 of the phantom was set as the test range, which included apex up to both costophrenic angles. A total of 10 OSLD nanoDots were attached for measurement of the front and rear ESD. Cyclic tests were performed using the low-dose chest CT and high-resolution CT (HRCT) protocol on the following set-ups: without shielding; shielding only on the front side; shielding only on the rear side; and shielding for both front and rear sides. According to the test results, ESD for both front and rear sides was higher in HRCT than low-dose CT when radiation shielding was not used. It was also determined that, compared to the set-up that did not use the radiation shield, locating the radiation shield on the front side was effective in reducing front ESD, while locating the radiation shield on the rear side reduced rear ESD level. Shielding both the front and rear sides resulted in ESD reduction. In conclusion, it was confirmed that shielding the front and rear sides was the most effective method to reduce the ESD effect caused by scatter ray during radiography.

  6. How education for sustainable development is implemented in Germany: Looking through the lens of educational governance theory

    NASA Astrophysics Data System (ADS)

    Bormann, Inka; Nikel, Jutta

    2017-12-01

    The United Nations (UN) Decade of Education for Sustainable Development (ESD) aimed to integrate the principles, values and practices of sustainable development into all aspects of education and learning around the world. The authors of this article address the implementation process of ESD in Germany during the UN Decade (2005-2014). By undertaking a meta-analysis of the findings of four related sub-studies they carried out during a three-year project funded by the German Federal Ministry of Education and Research, the authors contribute to the understanding of the process of transferring the concept of ESD within a multi-level education system. They investigated this process at two levels - the federal state (a sub-national entity in Germany) and the communal level. Drawing on educational governance theory, the authors unveil principles, norms, rules and procedures in the coordination of action within constellations of heterogeneous actors contributing to the implementation of ESD in their social entities. The outcome of the meta-analysis describes an emerging governance regime in ESD, taking into consideration the following features impacting the coordination of action being carried out by the actors involved: (1) the understanding of the normative concept of ESD as content of negotiation; (2) the perceived opportunity for actors to gain and increase appreciation within the field of ESD as an incentive for and driver of engagement; and (3) the dynamic quality of the set-up, rules and principles of the coordination of action, which renders these subject to situative changes. In the final part of the paper, the findings are discussed from the perspectives of the theory of transfer and the current empirical basis of ESD policy and governance.

  7. Metrology of flat mirrors with a computer generated hologram

    NASA Astrophysics Data System (ADS)

    Pariani, Giorgio; Tresoldi, Daniela; Moschetti, Manuele; Riva, Marco; Bianco, Andrea; Zerbi, Filippo Maria

    2014-07-01

    We designed the interferometric test of a 300 mm flat mirror, based onto a spherical mirror and a dedicated CGH. The spherical beam of the interferometer is quasi collimated to the desired diameter by the spherical mirror, used slightly off-axis, and the CGH performs the residual wavefront correction. We performed tests on a 200 mm and 300 mm flat mirrors, and compared the results to the ones obtained by stitching, showing an accuracy well within the designed value. The possibility to calibrate the cavity by subtracting out the figure errors of the spherical mirror has also been evaluated.

  8. Endoscopic submucosal dissection in the West: Current status and future directions.

    PubMed

    Ma, Michael X; Bourke, Michael J

    2018-05-01

    Endoscopic submucosal dissection (ESD) was first conceptually described almost 30 years ago in Japan and is now widely practiced throughout East Asia. ESD expands the boundaries of endoscopic resection (ER) by allowing en bloc resection of large early neoplastic lesions within the gastrointestinal tract (GIT). This offers advantages over other ER techniques by facilitating definitive histological staging and curative treatment of early cancer in selected cases. Indeed, the experience of ESD in Eastern countries is significant, and excellent outcomes from high-volume centers are reported. The potential benefits of ESD are recognized by Western endoscopists, but its adoption has been limited. A number of factors contribute to this, including epidemiological differences in GIT neoplasia between Western and Eastern populations and limitations in training opportunities. In this review, we discuss the role of ESD, its current status and the future in Western endoscopic practice. © 2017 Japan Gastroenterological Endoscopy Society.

  9. Endoscopic submucosal dissection for esophageal squamous cell neoplasms.

    PubMed

    Fujishiro, Mitsuhiro; Kodashima, Shinya; Goto, Osamu; Ono, Satoshi; Niimi, Keiko; Yamamichi, Nobutake; Oka, Masashi; Ichinose, Masao; Omata, Masao

    2009-04-01

    Endoscopic submucosal dissection (ESD) has gradually gained acceptance as one of the standard treatments for early esophageal cancer, as well as for early gastric cancer in Japan, but standardization of the knowledge is still incomplete. The final goal to perform ESD is not to resect the lesion in an en bloc fashion, but to save the patient from esophageal cancer-related death. Thus, the indications should be considered based on the entire patient, not just the target lesion itself, and pre-, peri- and postoperative management of the patient is also very important, as well as technical aspects of ESD. In terms of the techniques of ESD, owing to refinement of the procedural strategy, invention of the devices, and the learning curve, acceptable safety and favorable middle-term efficacy have been obtained. We believe that ESD will become a standard treatment for early esophageal cancer not only in Japan but also worldwide in the near future.

  10. Counter traction makes endoscopic submucosal dissection easier.

    PubMed

    Oyama, Tsuneo

    2012-11-01

    Poor counter traction and poor field of vision make endoscopic submucosal dissection (ESD) difficult. Good counter traction allows dissections to be performed more quickly and safely. Position change, which utilizes gravity, is the simplest method to create a clear field of vision. It is useful especially for esophageal and colon ESD. The second easiest method is clip with line method. Counter traction made by clip with line accomplishes the creation of a clear field of vision and suitable counter traction thereby making ESD more efficient and safe. The author published this method in 2002. The name ESD was not established in those days; the name cutting endoscopic mucosal resection (EMR) or EMR with hook knife was used. The other traction methods such as external grasping forceps, internal traction, double channel scope, and double scopes method are introduced in this paper. A good strategy for creating counter traction makes ESD easier.

  11. Results Of Insulation Resistance Between Solar Cell String Gaps Without RTV Adhesive Grout After Electrostatic Discharge Tests With Cover Glass Flashover

    NASA Astrophysics Data System (ADS)

    Hoang, Bao; Wong, Frankie; Redick, Tod; Masui, Hirokazu; Endo, Taishi; Toyoda, Kazuhiro; Cho, Mengu

    2011-10-01

    A series of electrostatic discharge (ESD) tests was performed on solar array test coupons consisting of Advanced Triple Junction InGaP2/InGaAs/Ge solar cells. The motivation for these tests was to evaluate the effects of ESD on solar array design without room temperature vulcanized (RTV) adhesive grout between the string-to-string parallel gaps. To investigate the threshold of permanently sustained secondary arcs, various combinations of gap width, load voltage and string current were tested in a vacuum chamber equipped with an electron beam gun. This ESD test program included the ESD test circuit with simulated panel coverglass flashover. Although ESD events did not result in permanent sustained arcs, the insulation resistance between strings was found to decrease as the number of secondary arcs accumulated in the gap.

  12. High efficiency and enhanced ESD properties of UV LEDs by inserting p-GaN/p-AlGaN superlattice

    NASA Astrophysics Data System (ADS)

    Huang, Yong; Li, PeiXian; Yang, Zhuo; Hao, Yue; Wang, XiaoBo

    2014-05-01

    Significantly improved electrostatic discharge (ESD) properties of InGaN/GaN-based UV light-emitting diode (LED) with inserting p-GaN/p-AlGaN superlattice (p-SLs) layers (instead of p-AlGaN single layer) between multiple quantum wells and Mg-doped GaN layer are reported. The pass yield of the LEDs increased from 73.53% to 93.81% under negative 2000 V ESD pulses. In addition, the light output power (LOP) and efficiency droop at high injection current were also improved. The mechanism of the enhanced ESD properties was then investigated. After excluding the effect of capacitance modulation, high-resolution X-ray diffraction (XRD) and atomic force microscope (AFM) measurements demonstrated that the dominant mechanism of the enhanced ESD properties is the material quality improved by p-SLs, which indicated less leakage paths, rather than the current spreading improved by p-SLs.

  13. Effect of Particle Morphology on the Reactivity of Explosively Dispersed Titanium Particles

    NASA Astrophysics Data System (ADS)

    Frost, David L.; Cairns, Malcolm; Goroshin, Samuel; Zhang, Fan

    2009-12-01

    The effect of particle morphology on the reaction of titanium (Ti) particles explosively dispersed during the detonation of either cylindrical or spherical charges has been investigated experimentally. The explosive charges consisted of packed beds of Ti particles saturated with nitromethane. The reaction behaviour of irregularly-shaped Ti particles in three size ranges is compared with tests with spherical Ti particles. The particle reaction is strongly dependent on particle morphology, e.g., 95 μm spherical Ti particles failed to ignite (in cylinders up to 49 mm in dia), whereas similarly sized irregular Ti particles readily ignited. For irregular particles, the uniformity of ignition on the particle cloud surface was almost independent of particle size, but depended on charge diameter. As the charge diameter was reduced, ignition in the conically expanding particle cloud occurred only at isolated spots or bands. For spherical charges, whereas large irregular Ti particles ignited promptly and uniformly throughout the particle cloud, the smallest particles dispersed nonuniformly and ignition occurred at isolated locations after a delay. Hence the charge geometry, as well as particle morphology, influences the reaction behaviour of the particles.

  14. Droplet characteristic measurement in Fourier interferometry imaging and behavior at the rainbow angle.

    PubMed

    Briard, Paul; Saengkaew, Sawitree; Wu, Xuecheng; Meunier-Guttin-Cluzel, Siegfried; Chen, Linghong; Cen, Kefa; Gréhan, Gérard

    2013-01-01

    This paper presents the possibility of measuring the three-dimensional (3D) relative locations and diameters of a set of spherical particles and discusses the behavior of the light recorded around the rainbow angle, an essential step toward refractive index measurements. When a set of particles is illuminated by a pulsed incident wave, the particles act as spherical light wave sources. When the pulse duration is short enough to fix the particle location (typically about 10 ns), interference fringes between these different spherical waves can be recorded. The Fourier transform of the fringes divides the complex fringe systems into a series of spots, with each spot characterizing the interference between a pair of particles. The analyses of these spots (in position and shape) potentially allow the measurement of particle characteristics (3D relative position, particle diameter, and particle refractive index value).

  15. ESD Implementation at the School Organisation Level, Part 2--Investigating the Transformative Perspective in School Leaders' Quality Strategies at ESD Schools

    ERIC Educational Resources Information Center

    Mogren, Anna; Gericke, Niklas

    2017-01-01

    Previous research has suggested that adopting a transformative school organisation perspective when implementing ESD may be more productive than the previously recommended transmissive perspectives, but it is not clear how transformative perspectives could be introduced. To address this issue, we conducted an empirical mixed methods study of…

  16. An Interdisciplinary Approach to Environmental and Sustainability Education: Developing Geography Students' Understandings of Sustainable Development Using Poetry

    ERIC Educational Resources Information Center

    Walshe, Nicola

    2017-01-01

    Education for sustainable development (ESD) persists as an important concept within international policy and yet, despite considerable debate, there remains a lack of consensus as to a pedagogy for ESD in schools. This paper presents findings from a study investigating how an interdisciplinary approach to ESD in England developed one class of 16-…

  17. Practicing ESD at School: Integration of Formal and Nonformal Education Methods Based on the Earth Charter (Belarusian Experience)

    ERIC Educational Resources Information Center

    Savelava, Sofia; Savelau, Dmitry; Cary, Marina Bakhnova

    2010-01-01

    The Earth Charter represents the philosophy and ethics necessary to create a new period of human civilization. Understanding and adoption of this new vision is the most important mission of education for sustainable development (ESD). This article argues that for successful implementation of ESD principles at school, the school education system…

  18. Tracing Sustainability: Education for Sustainable Development in the Lower Secondary Geography Curricula of Germany, Romania, and Mexico

    ERIC Educational Resources Information Center

    Bagoly-Simó, Péter

    2014-01-01

    Over the last two decades Education for Sustainable Development (ESD) has received increasing attention. Due to the close affinity that geography as a school subject shares with both theoretical constructs and methodologies of ESD, geography has assumed a key position in the implementation of ESD in formal education. Still, little attention has so…

  19. An ESD Pathway to Quality Education in the Cyprus Primary Education Context

    ERIC Educational Resources Information Center

    Kadji-Beltran, Chrysanthi; Christodoulou, Nicoletta; Zachariou, Aravella; Lindemann-Matthies, Petra; Barker, Susan; Kadis, Costas

    2017-01-01

    This research is based on the rationale that the well-defined framework of education for sustainable development (ESD), its connection with real life and its specific integration in the educational policies and curricula can help to enhance quality education (QE) in a meaningful and identifiable way. In a first step, the common ground of ESD and…

  20. Tips for safety in endoscopic submucosal dissection for colorectal tumors

    PubMed Central

    Naito, Yuji; Murakami, Takaaki; Hirose, Ryohei; Ogiso, Kiyoshi; Inada, Yutaka; Abdul Rani, Rafiz; Kishimoto, Mitsuo; Nakanishi, Masayoshi; Itoh, Yoshito

    2017-01-01

    In Japan, endoscopic submucosal dissection (ESD) becomes one of standard therapies for large colorectal tumors. Recently, the efficacy of ESD has been reported all over the world. However, it is still difficult even for Japanese experts in some situations. Right-sided location, large tumor size, high degree of fibrosis, difficult manipulation is related with the difficulty. However, improvements on ESD devices, suitable strategies, and increase of operators’ experiences enable us to solve these problems. In this chapter, we introduce recent topics about various difficult factors of colorectal ESD and the tips such as strategy, devices, injection, and traction method [Pocket-creation method (PCM) etc.]. PMID:28616400

  1. Feasibility and safety of endoscopic submucosal dissection for lower rectal tumors with hemorrhoids.

    PubMed

    Tanaka, Shinwa; Toyonaga, Takashi; Morita, Yoshinori; Hoshi, Namiko; Ishida, Tsukasa; Ohara, Yoshiko; Yoshizaki, Tetsuya; Kawara, Fumiaki; Umegaki, Eiji; Azuma, Takeshi

    2016-07-21

    To evaluate the feasibility and safety of endoscopic submucosal dissection (ESD) for lower rectal lesions with hemorrhoids. The outcome of ESD for 23 lesions with hemorrhoids (hemorrhoid group) was compared with that of 48 lesions without hemorrhoids extending to the dentate line (non-hemorrhoid group) during the same study period. Median operation times (ranges) in the hemorrhoid and non-hemorrhoid groups were 121 (51-390) and 130 (28-540) min. The en bloc resection rate and the curative resection rate in the hemorrhoid group were 96% and 83%, and they were 100% and 90% in the non-hemorrhoid group, respectively. In terms of adverse events, perforation and postoperative bleeding did not occur in both groups. In terms of the clinical course of hemorrhoids after ESD, the rate of complete recovery of hemorrhoids after ESD in lesions with resection of more than 90% was significantly higher than that in lesions with resection of less than 90%. ESD on lower rectal lesions with hemorrhoids could be performed safely, similarly to that on rectal lesions extending to the dentate line without hemorrhoids. In addition, all hemorrhoids after ESD improved to various degrees, depending on the resection range.

  2. Feasibility and safety of endoscopic submucosal dissection for lower rectal tumors with hemorrhoids

    PubMed Central

    Tanaka, Shinwa; Toyonaga, Takashi; Morita, Yoshinori; Hoshi, Namiko; Ishida, Tsukasa; Ohara, Yoshiko; Yoshizaki, Tetsuya; Kawara, Fumiaki; Umegaki, Eiji; Azuma, Takeshi

    2016-01-01

    AIM: To evaluate the feasibility and safety of endoscopic submucosal dissection (ESD) for lower rectal lesions with hemorrhoids. METHODS: The outcome of ESD for 23 lesions with hemorrhoids (hemorrhoid group) was compared with that of 48 lesions without hemorrhoids extending to the dentate line (non-hemorrhoid group) during the same study period. RESULTS: Median operation times (ranges) in the hemorrhoid and non-hemorrhoid groups were 121 (51-390) and 130 (28-540) min. The en bloc resection rate and the curative resection rate in the hemorrhoid group were 96% and 83%, and they were 100% and 90% in the non-hemorrhoid group, respectively. In terms of adverse events, perforation and postoperative bleeding did not occur in both groups. In terms of the clinical course of hemorrhoids after ESD, the rate of complete recovery of hemorrhoids after ESD in lesions with resection of more than 90% was significantly higher than that in lesions with resection of less than 90%. CONCLUSION: ESD on lower rectal lesions with hemorrhoids could be performed safely, similarly to that on rectal lesions extending to the dentate line without hemorrhoids. In addition, all hemorrhoids after ESD improved to various degrees, depending on the resection range. PMID:27468216

  3. Differential Diagnosis of Erythmato-Squamous Diseases Using Classification and Regression Tree

    PubMed Central

    Maghooli, Keivan; Langarizadeh, Mostafa; Shahmoradi, Leila; Habibi-koolaee, Mahdi; Jebraeily, Mohamad; Bouraghi, Hamid

    2016-01-01

    Introduction: Differential diagnosis of Erythmato-Squamous Diseases (ESD) is a major challenge in the field of dermatology. The ESD diseases are placed into six different classes. Data mining is the process for detection of hidden patterns. In the case of ESD, data mining help us to predict the diseases. Different algorithms were developed for this purpose. Objective: we aimed to use the Classification and Regression Tree (CART) to predict differential diagnosis of ESD. Methods: we used the Cross Industry Standard Process for Data Mining (CRISP-DM) methodology. For this purpose, the dermatology data set from machine learning repository, UCI was obtained. The Clementine 12.0 software from IBM Company was used for modelling. In order to evaluation of the model we calculate the accuracy, sensitivity and specificity of the model. Results: The proposed model had an accuracy of 94.84% ( Standard Deviation: 24.42) in order to correct prediction of the ESD disease. Conclusions: Results indicated that using of this classifier could be useful. But, it would be strongly recommended that the combination of machine learning methods could be more useful in terms of prediction of ESD. PMID:28077889

  4. Operationalizing sustainability in urban coastal systems: a system dynamics analysis.

    PubMed

    Mavrommati, Georgia; Bithas, Kostas; Panayiotidis, Panayiotis

    2013-12-15

    We propose a system dynamics approach for Ecologically Sustainable Development (ESD) in urban coastal systems. A systematic analysis based on theoretical considerations, policy analysis and experts' knowledge is followed in order to define the concept of ESD. The principles underlying ESD feed the development of a System Dynamics Model (SDM) that connects the pollutant loads produced by urban systems' socioeconomic activities with the ecological condition of the coastal ecosystem that it is delineated in operational terms through key biological elements defined by the EU Water Framework Directive. The receiving waters of the Athens Metropolitan area, which bears the elements of typical high population density Mediterranean coastal city but which currently has also new dynamics induced by the ongoing financial crisis, are used as an experimental system for testing a system dynamics approach to apply the concept of ESD. Systems' thinking is employed to represent the complex relationships among the components of the system. Interconnections and dependencies that determine the potentials for achieving ESD are revealed. The proposed system dynamics analysis can facilitate decision makers to define paths of development that comply with the principles of ESD. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Management of early colonic neoplasia: where are we now and where are we heading?

    PubMed

    Longcroft-Wheaton, Gaius; Bhandari, Pradeep

    2017-03-01

    There have been considerable advances in the endoscopic treatment of colorectal neoplasia. The development of endoscopic submucosal dissection and full thickness resection techniques is changing the way benign disease and early cancers are managed. This article reviews the evidence behind these new techniques and discusses where this field is likely to move in the future. Areas covered: A PubMed literature review of resection techniques for colonic neoplasia was performed. The clinical and cost effectiveness of endoscopic mucosal resection (EMR) is examined. The development of endoscopic submucosal dissection (ESD) and knife assisted resection is described and issues around training reviewed. Efficacy is compared to both EMR and transanal endoscopic microsurgery. The future is considered, including full thickness resection techniques and robotic endoscopy. Expert commentary: The perceived barriers to ESD are falling, and views that such techniques are only possible in Japan are disappearing. The key barriers to uptake will be training, and the development of educational programmes should be seen as a priority. The debate between TEMS and ESD will continue, but ESD is more flexible and cheaper. This will become less significant as the number of endoscopists trained in ESD grows and some TEMS surgeons may shift across towards ESD.

  6. [Characteristics of particle size structure of plankton community in turbidity zone of near-shore waters, Liaoning Province of Northeast China].

    PubMed

    Song, Lun; Wang, Nian-bin; Song, Yong-Gang; Li, Nan

    2013-04-01

    Estuary and nearshore waters have complicated environment, where plankton community has a frequent feedback regulation and a very unstable particle size structure. In this paper, an investigation was made on the particle size structure of plankton in the turbidity zone of nearshore and port area waters in Liaoning Province of Northeast China. In the waters with high concentration inorganic nitrogen, phytoplankton biomass was mainly of small particle sizes, with the equivalent sphere diameter (ESD) being primarily 20-100 micro m, while in low nutrient waters, the phytoplankton biomass was mainly of larger size particles, with the ESD>100 micro m, indicating that the phytoplankton feedback regulation caused the phytoplankton community to be comprised of small sized organisms as part of the biological responses to high concentration suspended solids, which reduced the individual number of larger organisms such as Coscinodiscus. sp. and other species, and in turn, directly affected the fisheries resources, including a variety of fish and shrimp larvae fed on phytoplankton. A normalized biomass size spectrum with the characteristics of nearshore shallow aquatic oceanic ecosystems exhibiting eutrophication was constructed. The spectrum slope indicated that the plankton community biomass would gradually increase in size. The feasibility of using dinoflagellates and cladocerans as the bio-indicators for eutrophication was discussed.

  7. Effect of aminoalkyl methacrylate copolymer E/HCl on in vivo absorption of poorly water-soluble drug.

    PubMed

    Yoshida, Takatsune; Kurimoto, Ippei; Yoshihara, Keiichi; Umejima, Hiroyuki; Ito, Naoki; Watanabe, Shunsuke; Sako, Kazuhiro; Kikuchi, Akihiko

    2013-11-01

    This study aimed to investigate in vivo absorption of tacrolimus formulated as a solid dispersion using Eudragit E®/HCl (E-SD). E-SD is an aminoalkyl methacrylate copolymer that can be dissolved under neutral pH conditions. E-SD was used alone as a solid dispersion carrier and/or was mixed with tacrolimus primarily dispersed with hydroxypropylmethylcellulose (HPMC). Tacrolimus was formulated with E-SD at several different ratios. Formulations with tacrolimus/E-SD ratio of 1/3 showed higher in vivo absorption, compared to tacrolimus dispersed in the excipients (primarily HPMC) found in commercially available tacrolimus capsules, using a rat in situ closed loop method. Good correlation was observed between in vitro drug solubility and in vivo drug absorption. In vitro solubility tests and rat oral absorption studies of tacrolimus/HPMC solid dispersion formulations were also conducted after mixing the HPMC dispersion with several ratios of E-SD. E-SD/tacrolimus/HPMC formulations yielded high in vitro drug solubility but comparatively low in vivo absorption. Dog oral absorption studies were conducted using capsules containing a formulation of tacrolimus/E-SD at a ratio of 1/5. The E-SD formulation-containing capsule showed higher in vivo drug absorption than tacrolimus dispersed in the standard HPMC capsule. These studies report enhancement of the in vivo absorption of a poorly water-soluble drug following dispersion with E-SD when compared to formulation in HPMC.

  8. Migratory life histories explain the extreme egg-size dimorphism of Eudyptes penguins.

    PubMed

    Crossin, Glenn T; Williams, Tony D

    2016-10-12

    When successive stages in the life history of an animal directly overlap, physiological conflicts can arise resulting in carryover effects from one stage to another. The extreme egg-size dimorphism (ESD) of Eudyptes penguins, where the first-laid A-egg is approximately 18-57% smaller than the second-laid B-egg, has interested researchers for decades. Recent studies have linked variation in this trait to a carryover effect of migration that limits the physiology of yolk production and egg sizes. We assembled data on ESD and estimates of migration-reproduction overlap in penguin species and use phylogenetic methods to test the idea that migration-reproduction overlap explains variation in ESD. We show that migration overlap is generally restricted to Eudyptes relative to non-Eudyptes penguins, and that this overlap (defined as the amount of time that egg production occurs on land versus at sea during homeward migration) is significantly and positively correlated with the degree of ESD in Eudyptes In the non-Eudyptes species, however, ESD was unrelated to migration overlap as these species mostly produce their clutches on land. Our results support the recent hypothesis that extreme ESD of Eudyptes penguins evolved, in part, as a response to selection for a pelagic overwinter migration behaviour. This resulted in a temporal overlap with, and thus a constraint on, the physiology of follicle development, leading to smaller A-egg size and greater ESD. © 2016 The Author(s).

  9. Direct measurement of a patient's entrance skin dose during pediatric cardiac catheterization

    PubMed Central

    Sun, Lue; Mizuno, Yusuke; Iwamoto, Mari; Goto, Takahisa; Koguchi, Yasuhiro; Miyamoto, Yuka; Tsuboi, Koji; Chida, Koichi; Moritake, Takashi

    2014-01-01

    Children with complex congenital heart diseases often require repeated cardiac catheterization; however, children are more radiosensitive than adults. Therefore, radiation-induced carcinogenesis is an important consideration for children who undergo those procedures. We measured entrance skin doses (ESDs) using radio-photoluminescence dosimeter (RPLD) chips during cardiac catheterization for 15 pediatric patients (median age, 1.92 years; males, n = 9; females, n = 6) with cardiac diseases. Four RPLD chips were placed on the patient's posterior and right side of the chest. Correlations between maximum ESD and dose–area products (DAP), total number of frames, total fluoroscopic time, number of cine runs, cumulative dose at the interventional reference point (IRP), body weight, chest thickness, and height were analyzed. The maximum ESD was 80 ± 59 (mean ± standard deviation) mGy. Maximum ESD closely correlated with both DAP (r = 0.78) and cumulative dose at the IRP (r = 0.82). Maximum ESD for coiling and ballooning tended to be higher than that for ablation, balloon atrial septostomy, and diagnostic procedures. In conclusion, we directly measured ESD using RPLD chips and found that maximum ESD could be estimated in real-time using angiographic parameters, such as DAP and cumulative dose at the IRP. Children requiring repeated catheterizations would be exposed to high radiation levels throughout their lives, although treatment influences radiation dose. Therefore, the radiation dose associated with individual cardiac catheterizations should be analyzed, and the effects of radiation throughout the lives of such patients should be followed. PMID:24968708

  10. Outcomes of Endoscopic Submucosal Dissection vs Esophagectomy for T1 Esophageal Squamous Cell Carcinoma in a Real-world Cohort.

    PubMed

    Zhang, Yiqun; Ding, Han; Chen, Tao; Zhang, Xiaocen; Chen, Wei-Feng; Li, Quanlin; Yao, Liqing; Korrapati, Praneet; Jin, Xue-Juan; Zhang, Yong-Xing; Xu, Mei-Dong; Zhou, Ping-Hong

    2018-04-25

    Esophagectomy is the standard treatment for early-stage esophageal squamous cell carcinoma (EESCC), but patients who undergo this procedure have high morbidity and mortality. Endoscopic submucosal dissection (ESD) is a less-invasive procedure for treatment of EESCC, but is considered risky because this tumor frequently metastasizes to the lymph nodes. We aimed to directly compare outcomes of patients with EESCC treated with ESD vs esophagectomy. We performed a retrospective cohort study of patients with T1a-m2/m3, or T1b EESCCs who underwent ESD (n=322) or esophagectomy (n=274) from October 1, 2011 through September 31, 2016 at Zhongshan Hospital in Shanghai, China. The primary outcome was all-cause mortality at the end of follow up (minimum of 6 months). Secondary outcomes included operation time, hospital stay, cost, perioperative mortalities/severe non-fatal adverse events, requirement for adjuvant therapies, and disease-specific mortality and cancer recurrence or metastasis at the end of the follow up period. Patients who underwent ESD were older (mean 63.5 years vs 62.3 years for patients receiving esophagectomy; P=.006) and a greater proportion was male (80.1% vs 70.4%; P=.006) and had a T1a tumor (74.5% vs 27%; P=.001). A lower proportion of patients who underwent ESD had perioperative mortality (0.3% vs 1.5% of patients receiving esophagectomy; P=.186) and non-fatal severe adverse events (15.2% vs 27.7%; P=.001)-specifically lower proportions of esophageal fistula (0.3% of patients receiving ESD vs 16.4% for patients receiving esophagectomy; P=.001) and pulmonary complications (0.3% vs 3.6%; P=.004). After a median follow-up time of 21 months (range, 6-73 months), there were no significant differences between treatments in all-cause mortality (7.4% for ESD vs 10.9%; P=.209) or rate of cancer recurrence or metastasis (9.1% for ESD vs 8.9%; P=.948). Disease-specific mortality was lower among patients who received ESD (3.4%) vs patients who patients who received esophagectomy (7.4%) (P=.049). In Cox regression analysis, depth of tumor invasion was the only factor associated with all-cause mortality (T1a-m3 or deeper vs T1a-m2: hazard ration, 3.54; P=.04). In a retrospective study of patients with T1am2/m3 or T1b EESCCs treated with ESD (n=322) or esophagectomy (n=274), we found lower proportions of patients receiving ESD to have perioperative adverse events or disease specific mortality after a median follow up time of 21 months. We found no difference in overall survival or cancer recurrence or metastasis in patients with T1a or T1b ESCCs treated with ESD vs esophagectomy. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  11. Fabrication of precision glass shells by joining glass rods

    DOEpatents

    Gac, Frank D.; Blake, Rodger D.; Day, Delbert E.; Haggerty, John S.

    1988-01-01

    A method for making uniform spherical shells. The present invention allows niform hollow spheres to be made by first making a void in a body of material. The material is heated so that the viscosity is sufficiently low so that the surface tension will transform the void into a bubble. The bubble is allowed to rise in the body until it is spherical. The excess material is removed from around the void to form a spherical shell with a uniform outside diameter.

  12. Vertical interferometer workstation for testing large spherical optics

    NASA Astrophysics Data System (ADS)

    Truax, B.

    2013-09-01

    The design of an interferometer workstation for the testing of large concave and convex spherical optics is presented. The workstation handles optical components and mounts up to 425 mm in diameter with mass of up to 40 kg with 6 axes of adjustment. A unique method for the implementation of focus, roll and pitch was used allowing for extremely precise adjustment. The completed system includes transmission spheres with f-numbers from f/1.6 to f/0.82 incorporating reference surface diameters of up to 306 mm and surface accuracies of better than 63 nm PVr. The design challenges and resulting solutions are discussed. System performance results are presented.

  13. Fast discharge in a spherical cavity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Antsiferov, P. S., E-mail: Ants@isan.troitsk.ru; Dorokhin, L. A.

    2014-04-15

    The work is devoted to the study of the plasma, created by a fast discharge in a spherical cavity. The discharge was driven by an inductive storage with plasma erosion opening switch (dI/dt ∼10{sup 12} A/s). The plasma was produced in a spherical cavity (alumina, 11 mm diameter). Xe, Ar, and He at the pressure 80 Pa were used as working gases. The time evolution of the spatial structure and of extreme ultraviolet (EUV) spectra of the discharge plasma was studied by means of micro channel plate detector. The discharges with Xe and Ar resulted in the stable appearance of the spherically shapedmore » plasma with the diameter about 1–3 mm. The plasma emission in the EUV region lasts ∼500 ns. The EUV spectrum of Ar discharge at the moment of maximum of the electron temperature T{sub e} contains the lines of Ar X (ionization potential 478.7 eV), that indicates a value of T{sub e} in the range 50–100 eV. The mechanism of plasma appearance can be the cumulation of the convergent spherical shock wave, generated by fast heat deposition and magnetic pressure in working media near the inner surface of the discharge volume.« less

  14. Influence of spherical aberration, stimulus spatial frequency, and pupil apodisation on subjective refractions

    PubMed Central

    Bradley, Arthur; Xu, Renfeng; Thibos, Larry; Marin, Gildas; Hernandez, Martha

    2014-01-01

    Purpose To test competing hypotheses (Stiles Crawford pupil apodising or superior imaging of high spatial frequencies by the central pupil) for the pupil size independence of subjective refractions in the presence of primary spherical aberration. Methods Subjective refractions were obtained with a variety of test stimuli (high contrast letters, urban cityscape, high and low spatial frequency gratings) while modulating pupil diameter, levels of primary spherical aberration and pupil apodisation. Subjective refractions were also obtained with low-pass and high-pass stimuli and using “darker” and “sharper” subjective criteria. Results Subjective refractions for stimuli containing high spatial frequencies focus a near paraxial region of the pupil and are affected only slightly by level of Seidel spherical aberration, degree of pupil apodisation and pupil diameter, and generally focused a radius of about 1 to 1.5 mm from the pupil centre. Low spatial frequency refractions focus a marginal region of the pupil, and are significantly affected by level of spherical aberration, amount of pupil apodisation, and pupil size. Clinical refractions that employ the “darker” or “sharper” subjective criteria bias the patient to use lower or higher spatial frequencies respectively. Conclusions In the presence of significant levels of spherical aberration, the pupil size independence of subjective refractions occurs with or without Stiles Crawford apodisation for refractions that optimise high spatial frequency content in the image. If low spatial frequencies are optimised by a subjective refraction, spherical refractive error varies with spherical aberration, pupil size, and level of apodisation. As light levels drop from photopic to scotopic, therefore, we expect a shift from pupil size independent to pupil size dependent subjective refractions. Emphasising a “sharper” criterion during subjective refractions will improve image quality for high spatial frequencies and generate pupil size independent refractions. PMID:24397356

  15. Clearing the Path That Has Been Laid: A Conceptualisation of Education for Sustainable Development

    ERIC Educational Resources Information Center

    Bentham, Hayley

    2013-01-01

    Education for sustainable development (ESD) has become so crucial that we have tried to smear it on anything and everything that is teachable. The consequence is that almost everything we do may be said to contain weak attributes of ESD even if we know nothing significant about it. This paper attempts to reveal an understanding of ESD that is…

  16. Contribution of Kobe University to the Regional Centre of Expertise (RCE) on Education for Sustainable Development (ESD) Hyogo-Kobe

    ERIC Educational Resources Information Center

    Itoh, Masayuki; Suemoto, Makoto; Matsuoka, Koji; Ito, Atsushi; Yui, Kiyomitsu; Matsuda, Tsuyoshi; Ishikawa, Masanobu

    2008-01-01

    Purpose: The purpose of this paper is to introduce the Regional Centre of Expertise (RCE) on education for sustainable development (ESD) Hyogo-Kobe, and the contribution of Kobe University as a model case. An attempt to develop and implement a new ESD programme in higher education is also reported. Design/methodology/approach: A brief description…

  17. Modeling of ESD events from polymeric surfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pfeifer, Kent Bryant

    2014-03-01

    Transient electrostatic discharge (ESD) events are studied to assemble a predictive model of discharge from polymer surfaces. An analog circuit simulation is produced and its response is compared to various literature sources to explore its capabilities and limitations. Results suggest that polymer ESD events can be predicted to within an order of magnitude. These results compare well to empirical findings from other sources having similar reproducibility.

  18. Combined position and diameter measures for lunar craters

    USGS Publications Warehouse

    Arthur, D.W.G.

    1977-01-01

    The note addresses the problem of simultaneously measuring positions and diameters of circular impact craters on wide-angle photographs of approximately spherical planets such as the Moon and Mercury. The method allows for situations in which the camera is not aligned on the planet's center. ?? 1977.

  19. The effect of a finite focal spot size on location dependent detectability in a fan beam CT system

    NASA Astrophysics Data System (ADS)

    Kim, Byeongjoon; Baek, Jongduk

    2017-03-01

    A finite focal spot size is one of the sources to degrade the resolution performance in a fan beam CT system. In this work, we investigated the effect of the finite focal spot size on signal detectability. For the evaluation, five spherical objects with diameters of 1 mm, 2 mm, 3 mm, 4 mm, and 5 mm were used. The optical focal spot size viewed at the iso-center was a 1 mm (height) × 1 mm (width) with a target angle of 7 degrees, corresponding to an 8.21 mm (i.e., 1 mm / sin (7°)) focal spot length. Simulated projection data were acquired using 8 × 8 source lets, and reconstructed by Hanning weighted filtered backprojection. For each spherical object, the detectability was calculated at (0 mm, 0 mm) and (0 mm, 200 mm) using two image quality metrics: pixel signal to noise ratio (SNR) and detection SNR. For all signal sizes, the pixel SNR is higher at the iso-center since the noise variance at the off-center is much higher than that at the iso-center due to the backprojection weightings used in direct fan beam reconstruction. In contrast, detection SNR shows similar values for different spherical objects except 1 mm and 2 mm diameter spherical objects. Overall, the results indicate the resolution loss caused by the finite focal spot size degrades the detection performance, especially for small objects with less than 2 mm diameter.

  20. Role of observation of live cases done by Japanese experts in the acquisition of ESD skills by a western endoscopist.

    PubMed

    Draganov, Peter V; Chang, Myron; Coman, Roxana M; Wagh, Mihir S; An, Qi; Gotoda, Takuji

    2014-04-28

    To evaluate the role of observation of experts performing endoscopic submucosal dissection (ESD) in the acquisition of ESD skills. This prospective study is documenting the learning curve of one Western endoscopist. The study consisted of three periods. In the first period (pre-observation), the trainee performed ESDs in animal models in his home institution in the United States. The second period (observation) consisted of visit to Japan and observation of live ESD cases done by experts. The observation of cases occurred over a 5-wk period. During the third period (post-observation), the trainee performed ESD in animal models in a similar fashion as in the first period. Three animal models were used: live 40-50 kg Yorkshire pig, explanted pig stomach model, and explanted pig rectum model. The outcomes from the ESDs done in the animal models before and after observation of live human cases (main study intervention) were compared. Statistical analysis of the data included: Fisher's exact test to compare distributions of a categorical variable, Wilcoxon rank sum test to compare distributions of a continuous variable between the two groups (pre-observation and post-observation), and Kruskal-Wallis test to evaluate the impact of lesion location and type of model (ex-vivo vs live pig) on lesion removal time. The trainee performed 38 ESDs in animal model (29 pre-observation/9 post-observation). The removal times post-observation were significantly shorter than those pre-observation (32.7 ± 15.0 min vs 63.5 ± 9.8 min, P < 0.001). To minimize the impact of improving physician skill, the 9 lesions post-observation were compared to the last 9 lesions pre-observation and the removal times remained significantly shorter (32.7 ± 15.0 min vs 61.0 ± 7.4 min, P = 0.0011). Regression analysis showed that ESD observation significantly reduced removal time when controlling for the sequence of lesion removal (P = 0.025). Furthermore, it was also noted a trend towards decrease in failure to remove lesions and decrease in complications after the period of observation. This study did not find a significant difference in the time needed to remove lesions in different animal models. This finding could have important implications in designing training programs due to the substantial difference in cost between live animal and explanted organ models. The main limitation of this study is that it reflects the experience of a single endoscopist. Observation of experts performing ESD over short period of time can significantly contribute to the acquisition of ESD skills.

  1. Method and apparatus for determining diameter and wall thickness of minute hollow spherical shells

    DOEpatents

    Steinman, D.A.

    1980-05-30

    Method and apparatus for determining diameter and wall thickness of hollow microspheres or shells wherein terminal velocities of shells traveling in fluid-filled conduits of differing diameters are measured. A wall-effect factor is determined as a ratio of the terminal velocities, and shell outside diameter may then be ascertained as a predetermined empirical function of wall-effect factor. For shells of known outside diameter, wall thickness may then be ascertained as a predetermined empirical function of terminal velocity in either conduit.

  2. Method and apparatus for determining diameter and wall thickness of minute hollow spherical shells

    DOEpatents

    Steinman, David A.

    1982-01-01

    Method and apparatus for determining diameter and wall thickness of hollow microspheres or shells wherein terminal velocities of shells traveling in fluid-filled conduits of differing diameters are measured. A wall-effect factor is determined as a ratio of the terminal velocities, and shell outside diameter may then be ascertained as a predetermined empirical function of wall-effect factor. For shells of known outside diameter, wall thickness may then be ascertained as a predetermined empirical function of terminal velocity in either conduit.

  3. Sphericity determination using resonant ultrasound spectroscopy

    DOEpatents

    Dixon, Raymond D.; Migliori, Albert; Visscher, William M.

    1994-01-01

    A method is provided for grading production quantities of spherical objects, such as roller balls for bearings. A resonant ultrasound spectrum (RUS) is generated for each spherical object and a set of degenerate sphere-resonance frequencies is identified. From the degenerate sphere-resonance frequencies and known relationships between degenerate sphere-resonance frequencies and Poisson's ratio, a Poisson's ratio can be determined, along with a "best" spherical diameter, to form spherical parameters for the sphere. From the RUS, fine-structure resonant frequency spectra are identified for each degenerate sphere-resonance frequency previously selected. From each fine-structure spectrum and associated sphere parameter values an asphericity value is determined. The asphericity value can then be compared with predetermined values to provide a measure for accepting or rejecting the sphere.

  4. Sphericity determination using resonant ultrasound spectroscopy

    DOEpatents

    Dixon, R.D.; Migliori, A.; Visscher, W.M.

    1994-10-18

    A method is provided for grading production quantities of spherical objects, such as roller balls for bearings. A resonant ultrasound spectrum (RUS) is generated for each spherical object and a set of degenerate sphere-resonance frequencies is identified. From the degenerate sphere-resonance frequencies and known relationships between degenerate sphere-resonance frequencies and Poisson's ratio, a Poisson's ratio can be determined, along with a 'best' spherical diameter, to form spherical parameters for the sphere. From the RUS, fine-structure resonant frequency spectra are identified for each degenerate sphere-resonance frequency previously selected. From each fine-structure spectrum and associated sphere parameter values an asphericity value is determined. The asphericity value can then be compared with predetermined values to provide a measure for accepting or rejecting the sphere. 14 figs.

  5. Vertical phase separation of 6,13-bis(triisopropylsilylethynyl) pentacene/poly(methyl methacrylate) blends prepared by electrostatic spray deposition for organic field-effect transistors

    NASA Astrophysics Data System (ADS)

    Onojima, Norio; Hara, Kazuhiro; Nakamura, Ayato

    2017-05-01

    Blend films composed of 6,13-bis(triisopropylsilylethynyl) pentacene (TIPS pentacene) and poly(methyl methacrylate) (PMMA) were prepared by electrostatic spray deposition (ESD). ESD is considered as an intermediate process between dry and wet processes since the solvent present in small droplets can almost be evaporated before arriving at the substrate. Post-drying treatments with the time-consuming evaporation of residual solvents can be omitted. However, it is still not clear that a vertically phase-separated structure can be formed in the ESD process since the vertical phase separation of the blend films is associated with the solvent evaporation. In this study, we fabricated bottom-gate, top-contact organic field-effect transistors based on the blend films prepared by ESD and the devices exhibited transistor behavior with small hysteresis. This result demonstrates that the vertical phase separation of a blend film (upper TIPS pentacene active layer/bottom PMMA gate insulator) can occur in the facile one-step ESD process.

  6. ESD prevention, combating ESD problem — Solutions

    NASA Astrophysics Data System (ADS)

    Duban, M.

    2002-12-01

    In today's Electronic equipment manufacturing, managing an ESD (Electro static Discharge) plan is an integral part of a complete quality program. Every body has been in presence of static electricity one day or an other. But a discharge on a body of man is only felt when the potential of charge before the discharge is higher than 3000 volts but components can have a sensitivity less than 20 Volts !

  7. Mechanism of Electro-Static Discharge (ESD) Sensitivity of Reactive Powders and Its Mitigation

    DTIC Science & Technology

    2011-03-14

    motivated by both safety requirements for handling flammable gas mixtures and convenience of using spark discharge as a controlled energy igniter for...On the other hand, experimental tests of ESD ignition sensitivity for non-aerosolized powders are among the most commonly used safety assessments...materials, including nanomaterials for a variety of applications. Current protocols used for ESD ignition sensitivity testing, e.g., described in

  8. High-density collagen patch prevents stricture after endoscopic circumferential submucosal dissection of the esophagus: a porcine model.

    PubMed

    Aoki, Shigehisa; Sakata, Yasuhisa; Shimoda, Ryo; Takezawa, Toshiaki; Oshikata-Miyazaki, Ayumi; Kimura, Hiromi; Yamamoto, Mihoko; Iwakiri, Ryuichi; Fujimoto, Kazuma; Toda, Shuji

    2017-05-01

    Extensive excision of the esophageal mucosa by endoscopic submucosal dissection (ESD) frequently evokes a luminal stricture. This study aimed to determine the efficacy of a high-density collagen patch for the prevention of esophageal stricture in extensive ESD. Six pigs underwent circumferential esophageal ESD under general anesthesia. In 3 pigs, artificial ulcers were covered by 2 collagen patches. The other 3 pigs underwent circumferential ESD only. The 2 collagen patches were settled onto the ulcer surface using a general endoscope and instruments. The collagen patch-treated group showed significantly better patency rates on both the oral and anal sides of the wound area compared with the control group at day 14. The mucosal re-epithelization ratio was significantly promoted, and the extent of mucosal inflammation and fibrosis was significantly decreased with the collagen patch treatment in the wound area. The frequency of cells positive α-smooth muscle actin was significantly reduced in the collagen patch-treated group compared with the control group. We have established a high-density collagen device that can reduce the esophageal stricture associated with extensive ESD. This easy-to-handle device would be useful during superficial esophageal cancer treatment by ESD. Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  9. Examining the Stationarity Assumption for Statistically Downscaled Climate Projections of Precipitation

    NASA Astrophysics Data System (ADS)

    Wootten, A.; Dixon, K. W.; Lanzante, J. R.; Mcpherson, R. A.

    2017-12-01

    Empirical statistical downscaling (ESD) approaches attempt to refine global climate model (GCM) information via statistical relationships between observations and GCM simulations. The aim of such downscaling efforts is to create added-value climate projections by adding finer spatial detail and reducing biases. The results of statistical downscaling exercises are often used in impact assessments under the assumption that past performance provides an indicator of future results. Given prior research describing the danger of this assumption with regards to temperature, this study expands the perfect model experimental design from previous case studies to test the stationarity assumption with respect to precipitation. Assuming stationarity implies the performance of ESD methods are similar between the future projections and historical training. Case study results from four quantile-mapping based ESD methods demonstrate violations of the stationarity assumption for both central tendency and extremes of precipitation. These violations vary geographically and seasonally. For the four ESD methods tested the greatest challenges for downscaling of daily total precipitation projections occur in regions with limited precipitation and for extremes of precipitation along Southeast coastal regions. We conclude with a discussion of future expansion of the perfect model experimental design and the implications for improving ESD methods and providing guidance on the use of ESD techniques for impact assessments and decision-support.

  10. Risk Factors of Post-Endoscopic Submucosal Dissection Electrocoagulation Syndrome for Colorectal Neoplasm.

    PubMed

    Ito, Sayo; Hotta, Kinichi; Imai, Kenichiro; Yamaguchi, Yuichiro; Kishida, Yoshihiro; Takizawa, Kohei; Kakushima, Naomi; Tanaka, Masaki; Kawata, Noboru; Yoshida, Masao; Ishiwatari, Hirotoshi; Matsubayashi, Hiroyuki; Ono, Hiroyuki

    2018-06-04

    Colorectal endoscopic submucosal dissection (ESD) is used for the treatment of large colorectal superficial neoplasms. However, there have been no large studies on electrocoagulation syndrome developing after colorectal ESD. The aim of this study was to clarify the incidence and clinical risk factors of post-ESD electrocoagulation syndrome (PECS). A total of 692 patients (median age, 70 years; 395 men) with 692 lesions, who underwent colorectal ESD at a tertiary cancer center between July 2010 and December 2015 were eligible. PECS was clinically diagnosed based on the presence of localized abdominal tenderness matching the ESD enforcement site, and fever (>37.5°C) or an inflammatory response (C-reactive protein level >0.5 mg/dL or leukocytosis >10000 cells/μL), without obvious findings of perforation, which developed at >6 h post-ESD. Outcomes of the procedure, the incidence of PECS, and risk factors associated with PECS were assessed. The incidence of PECS was 4.8% (33 patients), and all patients improved by conservative treatment. On multivariate analysis, the female sex (odds ratio [OR] 2.6; 95% confidence interval [95% CI], 1.2-5.7), tumor location at the cecum (OR 14.5; 95% CI: 3.7-53.7 vs rectum), and the presence of submucosal fibrosis (OR 2.8; 95% CI: 1.1-7.5) were found to be independent risk factors of PECS. This study identified the risk factors for PECS. Patients with high risk factors of PECS require careful management after colorectal ESD. This article is protected by copyright. All rights reserved.

  11. Risk factors and management of positive horizontal margin in early gastric cancer resected by en bloc endoscopic submucosal dissection.

    PubMed

    Numata, Norifumi; Oka, Shiro; Tanaka, Shinji; Kagemoto, Kenichi; Sanomura, Yoji; Yoshida, Shigeto; Arihiro, Koji; Shimamoto, Fumio; Chayama, Kazuaki

    2015-04-01

    Although endoscopic submucosal dissection (ESD) is a widely accepted treatment for early gastric cancer (EGC), there is no consensus regarding the management of positive horizontal margin (HM) despite en bloc ESD. The aim of the current study was to identify the risk factors and optimal management of positive HM in EGCs resected by en bloc ESD. A total of 890 consecutive patients with 1,053 intramucosal EGCs resected by en bloc ESD between April 2005 and June 2011. Clinicopathological data were retrieved retrospectively to assess the positive HM rate, local recurrence rate, risk factors for positive HM, and outcomes of treatment for local recurrent tumor. Positive HM was defined as a margin with direct tumor invasion (type A), the presence of cancerous cells on either end of 2-mm-thick cut sections (type B), or an unclear tumor margin resulting from crush or burn damage (type C). The positive HM rate was 2.0% (21/1,053). The local recurrence rate was 0.3% (3/1,053). All local recurrent tumors were intramucosal carcinomas, and were resected curatively by re-ESD. Multivariate analysis with logistic regression showed tumor location in the upper third of the stomach and lesions not matching the absolute indication to be independent risk factors for positive HM. The risk factors for HM positivity in cases of EGC resected by en bloc ESD are tumor location in the upper third of the stomach and dissatisfaction of the absolute indication for curative ESD.

  12. Therapeutic outcomes of endoscopic submucosal dissection of differentiated early gastric cancer in a Western endoscopy setting (with video).

    PubMed

    Emura, Fabian; Mejía, Juan; Donneys, Alberto; Ricaurte, Orlando; Sabbagh, Luis; Giraldo-Cadavid, Luis; Oda, Ichiro; Saito, Yutaka; Osorio, Camilo

    2015-11-01

    Large multicenter gastric cancer endoscopic submucosal dissection (ESD) studies conducted at major Japanese institutions have reported en bloc resection, en bloc tumor-free margin resection, and curative resection rates of 92.7% to 96.1%, 82.6% to 94.5%, and 73.6% to 85.4%, respectively, with delayed bleeding and perforation rates of 0.6% to 6.0% and 3.6% to 4.7%, respectively. Although ESD is currently an alternative treatment in some countries, particularly in Asia, it remains uncertain whether ESD therapeutic outcomes in Western endoscopy settings can be comparable to those achieved in Japan. To evaluate the ESD therapeutic outcomes for differentiated early gastric cancer (EGC) in a Western endoscopy setting. Consecutive case series performed by an expertly trained Western endoscopist. Fifty-three patients with 54 lesions. ESD for early gastric cancers (T1) satisfying expanded inclusion criteria. En bloc resection, en bloc tumor-free margin resection, and curative resection rates were 98%, 93%, and 83%, respectively. The delayed bleeding rate was 7%, and the perforation rate was 4%. The mean patient age was 67 years, and the mean tumor size was 19.8 mm, with 54% of the lesions located in the lesser curvature. The median procedure time was 61 minutes, with ESD procedures 60 minutes or longer associated with submucosal fibrosis (P < .001) and tumor size 25 mm or larger (P = .03). In every ESD procedure, both circumferential incision and submucosal dissection were performed by using a single knife. Two of the 4 delayed bleeding cases required surgery, and all perforations were successfully managed by using endoscopic clips. Long-term outcome data are currently unavailable. ESD for differentiated EGC resulted in favorable therapeutic outcomes in a Western endoscopy setting comparable to those achieved at major Japanese institutions. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  13. Review of Exploration Systems Development (ESD) Integrated Hazard Development Process. Volume 1; Appendices

    NASA Technical Reports Server (NTRS)

    Smiles, Michael D.; Blythe, Michael P.; Bejmuk, Bohdan; Currie, Nancy J.; Doremus, Robert C.; Franzo, Jennifer C.; Gordon, Mark W.; Johnson, Tracy D.; Kowaleski, Mark M.; Laube, Jeffrey R.

    2015-01-01

    The Chief Engineer of the Exploration Systems Development (ESD) Office requested that the NASA Engineering and Safety Center (NESC) perform an independent assessment of the ESD's integrated hazard development process. The focus of the assessment was to review the integrated hazard analysis (IHA) process and identify any gaps/improvements in the process (e.g., missed causes, cause tree completeness, missed hazards). This document contains the outcome of the NESC assessment.

  14. Review of Exploration Systems Development (ESD) Integrated Hazard Development Process. Appendices; Volume 2

    NASA Technical Reports Server (NTRS)

    Smiles, Michael D.; Blythe, Michael P.; Bejmuk, Bohdan; Currie, Nancy J.; Doremus, Robert C.; Franzo, Jennifer C.; Gordon, Mark W.; Johnson, Tracy D.; Kowaleski, Mark M.; Laube, Jeffrey R.

    2015-01-01

    The Chief Engineer of the Exploration Systems Development (ESD) Office requested that the NASA Engineering and Safety Center (NESC) perform an independent assessment of the ESD's integrated hazard development process. The focus of the assessment was to review the integrated hazard analysis (IHA) process and identify any gaps/improvements in the process (e.g. missed causes, cause tree completeness, missed hazards). This document contains the outcome of the NESC assessment.

  15. Electrostatic Discharge (ESD) Susceptibility of Electronic Devices

    DTIC Science & Technology

    1983-01-01

    determined by knowing the thermal environment in which the component is to operate. However, ESD is not that predictable . It is considered a random... predicted where a part may experience an ESD pulse during usage? (3) What effect does stressing a device with different models have on its propensity for...relatively low ESO threshold voltages (i.e., < 7000 volts) tend to be consistently high compared with their predicted level using EMP data. But at

  16. Do you have what it takes for challenging endoscopic submucosal dissection cases?

    PubMed Central

    Kim, Kyoung-Oh; Kim, Sung Jung; Kim, Tae Hyeon; Park, Jong-Jae

    2011-01-01

    Endoscopic submucosal dissection (ESD) is a widely accepted treatment for early gastric cancer (EGC), especially in Korea and Japan. The criteria for the therapeutic use of ESD for EGC have been expanded recently. However, attention should be drawn to the technical feasibility of the ESD treatment which depends on a lesion’s location, size or fibrosis level, or operator’s experience. In the case of a lesion with a high level of difficulty, a more experienced operator is required. Thus, the treatment for a lesion with a high level of difficulty should be performed according to the degree of the operator’s experience. In this paper, the authors describe the ESD procedure for lesions with a high level of difficulty. PMID:21987603

  17. Effect of Particle Morphology on the Reactivity of Explosively Dispersed Titanium Particles

    NASA Astrophysics Data System (ADS)

    Frost, David; Cairns, Malcolm; Goroshin, Samuel; Zhang, Fan

    2009-06-01

    The effect of particle morphology on the reaction of titanium (Ti) particles explosively dispersed during the detonation of either cylindrical or spherical charges has been investigated experimentally. The explosive charges consisted of packed beds of Ti particles saturated with nitromethane. The reaction behavior of irregularly-shaped Ti particles in three size ranges is compared with tests with spherical Ti particles. The particle reaction is strongly dependent on particle morphology, e.g., 95 μm spherical Ti particles failed to ignite (in cylinders up to 49 mm in dia), whereas similarly sized irregular Ti particles readily ignited. For irregular particles, the uniformity of ignition on the particle cloud surface was almost independent of particle size, but depended on charge diameter. As the charge diameter was reduced, ignition in the conically expanding particle cloud occurred only at isolated spots or bands. For spherical charges, although large irregular Ti particles ignited promptly and uniformly throughout the particle cloud, the smallest particles dispersed nonuniformly and ignition occurred at isolated locations. In general, particle ignition is a competition between particle heating (which is influenced by particle morphology, size, number density and the local thermodynamic history) and expansion cooling of the products.

  18. Characterization of Particle Size Standard NIST 1019b with SynchrotronX-ray Microtomography and Digital Data Extraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Friedrich, Jon M.; Rivers, Mark L.; Perlowitz, Michael A.

    We show that synchrotron x-ray microtomography ({mu}CT) followed by digital data extraction can be used to examine the size distribution and particle morphologies of the polydisperse (750 to 2450 {micro}m diameter) particle size standard NIST 1019b. Our size distribution results are within errors of certified values with data collected at 19.5 {micro}m/voxel. One of the advantages of using {mu}CT to investigate the particles examined here is that the morphology of the glass beads can be directly examined. We use the shape metrics aspect ratio and sphericity to examine of individual standard beads morphologies as a function of spherical equivalent diameters.more » We find that the majority of standard beads possess near-spherical aspect ratios and sphericities, but deviations are present at the lower end of the size range. The majority (> 98%) of particles also possess an equant form when examined using a common measure of equidimensionality. Although the NIST 1019b standard consists of loose particles, we point out that an advantage of {mu}CT is that coherent materials comprised of particles can be examined without disaggregation.« less

  19. Penetration of Fiber Versus Spherical Particles Through Filter Media and Faceseal Leakage of N95 Filtering Facepiece Respirators with Cyclic Flow

    PubMed Central

    Cho, Kyungmin Jacob; Turkevich, Leonid; Miller, Matthew; McKay, Roy; Grinshpun, Sergey A.; Ha, KwonChul; Reponen, Tiina

    2015-01-01

    This study investigated differences in penetration between fibers and spherical particles through faceseal leakage of an N95 filtering facepiece respirator. Three cyclic breathing flows were generated corresponding to mean inspiratory flow rates (MIF) of 15, 30, and 85 L/min. Fibers had a mean diameter of 1 μm and a median length of 4.9 μm (calculated aerodynamic diameter, dae = 1.73 μm). Monodisperse polystyrene spheres with a mean physical diameter of 1.01 μm (PSI) and 1.54 μm (PSII) were used for comparison (calculated dae = 1.05 and 1.58 μm, respectively). Two optical particle counters simultaneously determined concentrations inside and outside the respirator. Geometric means (GMs) for filter penetration of the fibers were 0.06, 0.09, and 0.08% at MIF of 15, 30, and 85 L/min, respectively. Corresponding values for PSI were 0.07, 0.12, and 0.12%. GMs for faceseal penetration of fibers were 0.40, 0.14, and 0.09% at MIF of 15, 30, and 85 L/min, respectively. Corresponding values for PSI were 0.96, 0.41, and 0.17%. Faceseal penetration decreased with increased breathing rate for both types of particles (p ≤ 0.001). GMs of filter and faceseal penetration of PSII at an MIF of 30 L/min were 0.14% and 0.36%, respectively. Filter penetration and faceseal penetration of fibers were significantly lower than those of PSI (p < 0.001) and PSII (p < 0.003). This confirmed that higher penetration of PSI was not due to slightly smaller aerodynamic diameter, indicating that the shape of fibers rather than their calculated mean aerodynamic diameter is a prevailing factor on deposition mechanisms through the tested respirator. In conclusion, faceseal penetration of fibers and spherical particles decreased with increasing breathing rate, which can be explained by increased capture by impaction. Spherical particles had 2.0–2.8 times higher penetration through faceseal leaks and 1.1–1.5 higher penetration through filter media than fibers, which can be attributed to differences in interception losses. PMID:23339437

  20. Penetration of fiber versus spherical particles through filter media and faceseal leakage of N95 filtering facepiece respirators with cyclic flow.

    PubMed

    Cho, Kyungmin Jacob; Turkevich, Leonid; Miller, Matthew; McKay, Roy; Grinshpun, Sergey A; Ha, KwonChul; Reponen, Tiina

    2013-01-01

    This study investigated differences in penetration between fibers and spherical particles through faceseal leakage of an N95 filtering facepiece respirator. Three cyclic breathing flows were generated corresponding to mean inspiratory flow rates (MIF) of 15, 30, and 85 L/min. Fibers had a mean diameter of 1 μm and a median length of 4.9 μm (calculated aerodynamic diameter, d(ae) = 1.73 μm). Monodisperse polystyrene spheres with a mean physical diameter of 1.01 μm (PSI) and 1.54 μm (PSII) were used for comparison (calculated d(ae) = 1.05 and 1.58 μm, respectively). Two optical particle counters simultaneously determined concentrations inside and outside the respirator. Geometric means (GMs) for filter penetration of the fibers were 0.06, 0.09, and 0.08% at MIF of 15, 30, and 85 L/min, respectively. Corresponding values for PSI were 0.07, 0.12, and 0.12%. GMs for faceseal penetration of fibers were 0.40, 0.14, and 0.09% at MIF of 15, 30, and 85 L/min, respectively. Corresponding values for PSI were 0.96, 0.41, and 0.17%. Faceseal penetration decreased with increased breathing rate for both types of particles (p ≤ 0.001). GMs of filter and faceseal penetration of PSII at an MIF of 30 L/min were 0.14% and 0.36%, respectively. Filter penetration and faceseal penetration of fibers were significantly lower than those of PSI (p < 0.001) and PSII (p < 0.003). This confirmed that higher penetration of PSI was not due to slightly smaller aerodynamic diameter, indicating that the shape of fibers rather than their calculated mean aerodynamic diameter is a prevailing factor on deposition mechanisms through the tested respirator. In conclusion, faceseal penetration of fibers and spherical particles decreased with increasing breathing rate, which can be explained by increased capture by impaction. Spherical particles had 2.0-2.8 times higher penetration through faceseal leaks and 1.1-1.5 higher penetration through filter media than fibers, which can be attributed to differences in interception losses.

  1. Mesocarbon microbead based graphite for spherical fuel element to inhibit the infiltration of liquid fluoride salt in molten salt reactor

    NASA Astrophysics Data System (ADS)

    Zhong, Yajuan; Zhang, Junpeng; Lin, Jun; Xu, Liujun; Zhang, Feng; Xu, Hongxia; Chen, Yu; Jiang, Haitao; Li, Ziwei; Zhu, Zhiyong; Guo, Quangui

    2017-07-01

    Mesocarbon microbeads (MCMB) and quasi-isostatic pressing method were used to prepare MCMB based graphite (MG) for spherical fuel element to inhibit the infiltration of liquid fluoride salt in molten salt reactor (MSR). Characteristics of mercury infiltration and molten salt infiltration in MG were investigated and compared with A3-3 (graphite for spherical fuel element in high temperature gas cooled reactor) to identify the infiltration behaviors. The results indicated that MG had a low porosity about 14%, and an average pore diameter of 96 nm. Fluoride salt occupation of A3-3 (average pore diameter was 760 nm) was 10 wt% under 6.5 atm, whereas salt gain did not infiltrate in MG even up to 6.5 atm. It demonstrated that MG could inhibit the infiltration of liquid fluoride salt effectively. Coefficient of thermal expansion (CTE) of MG lies in 6.01 × 10-6 K-1 (α∥) and 6.15 × 10-6 K-1 (α⊥) at the temperature range of 25-700 °C. The anisotropy factor of MG calculated by CTE maintained below 1.02, which could meet the requirement of the spherical fuel element (below 1.30). The constant isotropic property of MG is beneficial for the integrity and safety of the graphite used in the spherical fuel element for a MSR.

  2. Clinical relevance of aberrant polypoid nodule scar after endoscopic submucosal dissection

    PubMed Central

    Arantes, Vitor; Uedo, Noriya; Pedrosa, Moises Salgado; Tomita, Yasuhiko

    2016-01-01

    AIM To describe a series of patients with aberrant polypoid nodule scar developed after gastric endoscopic submucosal dissection (ESD), and to discuss its pathogenesis and clinical management. METHODS We reviewed retrospectively the endoscopic database of two academic institutions located in Brazil and Japan and searched for all patients that underwent ESD to manage gastric neoplasms from 2003 to 2015. The criteria for admission in the study were: (1) successful en bloc ESD procedure with R0 and curative resection confirmed histologically; (2) postoperative endoscopic examination with identification of a polypoid nodule scar (PNS) at ESD scar; (3) biopsies of the PNS with hyperplastic or regenerative tissue, reviewed by two independent experienced gastrointestinal pathologists, one from each Institution. Data were examined for patient demographics, Helicobacter pylori status, precise neoplastic lesion location in the stomach, tumor size, histopathological assessment of the ESD specimen, and postoperative information including medical management, endoscopic and histological findings, and clinical outcome. RESULTS A total of 14 patients (10 men/4 women) fulfilled the inclusion criteria and were enrolled in this study. One center contributed with 8 cases out of 60 patients (13.3%) from 2008 to 2015. The second center contributed with 6 cases (1.7%) out of 343 patients from 2003 to 2015. Postoperative endoscopic follow-up revealed similar findings in all patients: A protruded polypoid appearing nodule situated in the center of the ESD scar surrounded by convergence of folds. Biopsies samples were taken from PNS, and histological assessment revealed in all cases regenerative and hyperplastic tissue, without recurrent tumor or dysplasia. Primary neoplastic lesions were located in the antrum in 13 patients and in the angle in one patient. PNS did not develop in any patient after ESD undertaken for tumors located in the corpus, fundus or cardia. All patients have been followed systematically on an annual basis and no malignant recurrence in the ESD scar has been identified (mean follow-up period: 45 mo). CONCLUSION PNS may occur after ESD for antral lesions and endoscopically look concerning, especially for the patient or the family doctor. However, as long as curative R0 resection was successfully achieved and histology demonstrates only regenerative and hyperplastic tissue, PNS should be viewed as a benign alteration that does not require any type of intervention, other than endoscopic surveillance. PMID:27668074

  3. The sagitta and lens thickness: the exact solution and a matrix approximation for lenses with toric, spherical, and cylindrical surfaces.

    PubMed

    Harris, W F

    1989-03-01

    The exact equation for sagitta of spherical surfaces is generalized to toric surfaces which include spherical and cylindrical surfaces as special cases. Lens thickness, therefore, can be calculated accurately anywhere on a lens even in cases of extreme spherical and cylindrical powers and large diameters. The sagittae of tire- and barrel-form toric surfaces differ off the principal meridians, as is shown by a numerical example. The same holds for pulley- and capstan-form toric surfaces. A general expression is given for thickness at an arbitrary point on a toric lens. Approximate expressions are derived and re-expressed in terms of matrices. The matrix provides an elegant means of generalizing equations for spherical surfaces and lenses to toric surfaces and lenses.

  4. Rebamipide solution: a novel submucosal injection material to promote healing speed and healing quality of ulcers induced by endoscopic submucosal dissection.

    PubMed

    Fujimoto, Ai; Uraoka, Toshio; Nishizawa, Toshihiro; Shimoda, Masayuki; Goto, Osamu; Ochiai, Yasutoshi; Maehata, Tadateru; Akimoto, Teppei; Mitsunaga, Yutaka; Sasaki, Motoki; Yamamoto, Hiroyuki; Yahagi, Naohisa

    2018-04-01

    Rebamipide is administered perorally to protect the gastric mucosa. We assessed the efficacy and safety of a novel rebamipide solution as a submucosal injection material for endoscopic submucosal dissection (ESD) using an in vivo porcine model. An endoscopist blinded to the test agents performed ESDs of hypothetical 30 mm lesions using a 2% rebamipide solution at 2 sites (rebamipide group) and a saline solution at 2 other sites (control group) in the stomachs of 8 pigs. The technical outcomes were compared between the 2 groups. The gastric ulcer stages were evaluated by endoscopy once weekly for 4 weeks after the ESD to determine the healing score (1-6). The pigs were killed at 1 week (n = 2), 2 weeks (n = 2), and 4 weeks (n = 4) after the ESD for pathologic evaluation of ESD-induced ulcers and scarring. There were no significant differences in any of the technical outcomes between the 2 groups, and no adverse events related to the ESD in any of the animals. The healing score was significantly higher in the rebamipide group than in the control group at 2 weeks (P = .027), 3 weeks (P = .034), and 4 weeks (P = .012). In the histopathologic assessment, fibrosis was significantly less extensive in the rebamipide group than in the control group at 2 weeks (P = .02) and 4 weeks (P = .04). The rebamipide solution appeared to promote both the speed and quality of healing of ESD-induced ulcers by suppressing fibrosis. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  5. Is the eCura system useful for selecting patients who require radical surgery after noncurative endoscopic submucosal dissection for early gastric cancer? A comparative study.

    PubMed

    Hatta, Waku; Gotoda, Takuji; Oyama, Tsuneo; Kawata, Noboru; Takahashi, Akiko; Yoshifuku, Yoshikazu; Hoteya, Shu; Nakagawa, Masahiro; Hirano, Masaaki; Esaki, Mitsuru; Matsuda, Mitsuru; Ohnita, Ken; Yamanouchi, Kohei; Yoshida, Motoyuki; Dohi, Osamu; Takada, Jun; Tanaka, Keiko; Yamada, Shinya; Tsuji, Tsuyotoshi; Ito, Hirotaka; Hayashi, Yoshiaki; Nakamura, Tomohiro; Nakaya, Naoki; Shimosegawa, Tooru

    2018-05-01

    We have established a risk-scoring system, termed the "eCura system," for the risk stratification of lymph node metastasis in patients who have received noncurative endoscopic submucosal dissection (ESD) for early gastric cancer (EGC). We aimed to clarify whether this system contributes to the selection of patients requiring radical surgery after ESD. Between 2000 and 2011, 1,969 patients with noncurative ESD for EGC were included in this multicenter study. Depending on the treatment strategy after ESD, we had patients with no additional treatment (n = 905) and those with radical surgery after ESD (n = 1,064). After the application of the eCura system to these patients, cancer recurrence and cancer-specific mortality in each risk category of the system were compared between the two patient groups. Multivariate Cox analysis revealed that in the high-risk category, cancer recurrence was significantly higher (hazard ratio = 3.13, p = 0.024) and cancer-specific mortality tended to be higher (hazard ratio = 2.66, p = 0.063) in patients with no additional treatment than in those with radical surgery after ESD, whereas no significant differences were observed in the intermediate-risk and low-risk categories. In addition, cancer-specific survival in the low-risk category was high in both patient groups (99.6 and 99.7%). A limitation of this study is that it included a small number of cases with undifferentiated-type EGC (292 cases). The eCura system is a useful aid for selecting the appropriate treatment strategy after noncurative ESD for EGC. However, caution is needed when applying this system to patients with undifferentiated-type EGC.

  6. pH-dependent structural change of the extracellular sensor domain of the DraK histidine kinase from Streptomyces coelicolor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yeo, Kwon Joo; Kim, Eun Hye; Hwang, Eunha

    2013-02-15

    Highlights: ► We described the biochemical and biophysical properties of the extracellular sensory domain (ESD) of DraK histidine kinase. ► The ESD of DraK showed a reversible pH-dependent conformational change in a wide pH range. ► The E83 is an important residue for the pH-dependent conformational change. -- Abstract: Recently, the DraR/DraK (Sco3063/Sco3062) two-component system (TCS) of Streptomycescoelicolor has been reported to be involved in the differential regulation of antibiotic biosynthesis. However, it has not been shown that under which conditions and how the DraR/DraK TCS is activated to initiate the signal transduction process. Therefore, to understand the sensing mechanism,more » structural study of the sensory domain of DraK is highly required. Here, we report the biochemical and biophysical properties of the extracellular sensory domain (ESD) of DraK. We observed a reversible pH-dependent conformational change of the ESD in a pH range of 2.5–10. Size-exclusion chromatography and AUC (analytical ultracentrifugation) data indicated that the ESD is predominantly monomeric in solution and exists in equilibrium between monomer and dimer states in acidic condition. Using NMR (nuclear magnetic resonance) and CD (circular dichroism) spectroscopy, our findings suggest that the structure of the ESD at low pH is more structured than that at high pH. In particular, the glutamate at position 83 is an important residue for the pH-dependent conformational change. These results suggest that this pH-dependent conformational change of ESD may be involved in signal transduction process of DraR/DraK TCS.« less

  7. Early supported discharge services for stroke patients: a meta-analysis of individual patients' data.

    PubMed

    Langhorne, Peter; Taylor, Gillian; Murray, Gordon; Dennis, Martin; Anderson, Craig; Bautz-Holter, Erik; Dey, Paola; Indredavik, Bent; Mayo, Nancy; Power, Michael; Rodgers, Helen; Ronning, Ole Morten; Rudd, Anthony; Suwanwela, Nijasri; Widen-Holmqvist, Lotta; Wolfe, Charles

    Stroke patients conventionally undergo a substantial part of their rehabilitation in hospital. Services have been developed that offer patients early discharge from hospital with rehabilitation at home (early supported discharge [ESD]). We have assessed the effects and costs of such services. We did a meta-analysis of data from individual patients who took part in randomised trials that recruited patients with stroke in hospital to receive either conventional care or any ESD service intervention that provided rehabilitation and support in a community setting with the aim of shortening the duration of hospital care. The primary outcome was death or dependency at the end of scheduled follow-up. Outcome data were available for 11 trials (1597 patients). ESD services were mostly provided by specialist multidisciplinary teams to a selected group (median 41%) of stroke patients admitted to hospital. There was a reduced risk of death or dependency equivalent to six (95% CI one to ten) fewer adverse outcomes for every 100 patients receiving an ESD service (p=0.02). The hospital stay was 8 days shorter for patients assigned ESD services than for those assigned conventional care (p<0.0001). There were also significant improvements in scores on the extended activities of daily living scale and in the odds of living at home and reporting satisfaction with services. The greatest benefits were seen in the trials evaluating a coordinated multidisciplinary ESD team and in stroke patients with mild to moderate disability. Appropriately resourced ESD services provided for a selected group of stroke patients can reduce long-term dependency and admission to institutional care as well as shortening hospital stays.

  8. Superfund record of decision amendment (EPA Region 4): Hercules 009 Landfill, Brunswick, GA, August 14, 1998

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1999-03-01

    This memorandum serves to present the Hercules 009 Landfill Superfund Site Explanation of Significant Difference (ESD) for concurrence. The Record of Decision (ROD) was signed on March 25, 1993 (PB94-964070). The ESD amends the ROD by changing the type of cover to be placed on the treated landfill soils and sludges. The ESD also explains EPA`s justification for determining the appropriate treatment depth in the landfill cells.

  9. Future Development of Endoscopic Accessories for Endoscopic Submucosal Dissection

    PubMed Central

    Jang, Jae-Young

    2017-01-01

    Endoscopic submucosal dissection (ESD) has recently been accepted as a standard treatment for patients with early gastric cancer (EGC), without lymph node metastases. Given the rise in the number of ESDs being performed, new endoscopic accessories are being developed and existing accessories modified to facilitate the execution of ESD and reduce complication rates. This paper examines the history underlying the development of these new endoscopic accessories and indicates future directions for the development of these accessories. PMID:28609819

  10. Cost comparison between surgical treatments and endoscopic submucosal dissection in patients with early gastric cancer in Korea.

    PubMed

    Kim, Younhee; Kim, Young Woo; Choi, Il Ju; Cho, Joo Young; Kim, Jong Hee; Kwon, Jin Won; Lee, Ja Youn; Lee, Na Rae; Seol, Sang Yong

    2015-03-01

    This study was conducted to evaluate whether medical costs can be reduced using endoscopic submucosal dissection (ESD) instead of conventional surger-ies in patients with early gastric cancer (EGC). Pa-tients who underwent open gastrectomy (OG), laparoscopy-assisted gastrectomy (LAG), and ESD for EGC were recruited from three medical institutions in 2009. For macro-costing, the medical costs for each patient were derived from the ex-penses incurred during the patient's hospital stay and 1-year follow-up. The overall costs in micro-costing were determined by multiplying the unit cost with the resources used during the patients' hospitalization. A total of 194 patients were included in this study. The hospital stay for ESD was 5 to 8 days and was significantly shorter than the 12-day hospital stay for OG or the 11- to 17-day stay for LAG. Using macro-costing, the average medical costs for ESD during the hospital stay ranged from 2.1 to 3.4 million Korean Won (KRW) per patient, and the medical costs for conventional surgeries were estimated to be between 5.1 million and 8.2 million KRW. There were no significant differences in the 1-year follow-up costs between ESD and conventional surger-ies. ESD patients had lower medical costs than those patients who had conventional surgeries for EGC with conservative indications. (Gut Liver, 2015;9174-180).

  11. Electrostatic Discharge Test of Multi-Junction Solar Array Coupons After Combined Space Environmental Exposures

    NASA Technical Reports Server (NTRS)

    Wright, Kenneth H.; Schneider, Todd; Vaughn, Jason; Hoang, Bao; Funderburk, Victor V.; Wong, Frankie; Gardiner, George

    2010-01-01

    A set of multi-junction GaAs/Ge solar array test coupons were subjected to a sequence of 5-year increments of combined environmental exposure tests. The test coupons capture an integrated design intended for use in a geosynchronous (GEO) space environment. A key component of this test campaign is conducting electrostatic discharge (ESD) tests in the inverted gradient mode. The protocol of the ESD tests is based on the ISO/CD 11221, the ISO standard for ESD testing on solar array panels. This standard is currently in its final review with expected approval in 2010. The test schematic in the ISO reference has been modified with Space System/Loral designed circuitry to better simulate the on-orbit operational conditions of its solar array design. Part of the modified circuitry is to simulate a solar array panel coverglass flashover discharge. All solar array coupons used in the test campaign consist of 4 cells. The ESD tests are performed at the beginning of life (BOL) and at each 5-year environment exposure point. The environmental exposure sequence consists of UV radiation, electron/proton particle radiation, thermal cycling, and ion thruster plume. This paper discusses the coverglass flashover simulation, ESD test setup, and the importance of the electrical test design in simulating the on-orbit operational conditions. Results from 5th-year testing are compared to the baseline ESD characteristics determined at the BOL condition.

  12. Technical feasibility of endoscopic submucosal dissection of gastrointestinal epithelial neoplasms with a splash-needle.

    PubMed

    Fujishiro, Mitsuhiro; Kodashima, Shinya; Goto, Osamu; Ono, Satoshi; Muraki, Yosuke; Kakushima, Naomi; Omata, Masao

    2008-12-01

    Endoscopic submucosal dissection (ESD) permits the resection of large gastrointestinal epithelial neoplasms and neoplasms with submucosal fibrosis in an en bloc manner. However, the high frequency of complications accompanying ESD and its complex processes suggests that the process requires improvement. A total of 22 consecutive patients with gastrointestinal epithelial neoplasms were enrolled during a 6-month period to evaluate a novel endosurgical knife for ESD. This novel knife is known as the "splash-needle," and it is thin, short needle with a water-irrigation function. The technical results revealed that the rates of bloc resection and en bloc resection with tumor-free lateral/basal margins (R0 resection) were 91% (20/22) and 82% (18/22), respectively. There was no significant bleeding or perforation during or after ESD. The median operation time was 60 minutes (range, 20 to 210). The splash-needle is a promising novel endosurgical knife that is useful for less complicated ESD. The accumulation of knowledge and cases verifying its usefulness is necessary, and a study comparing the knife with first-generation endosurgical knives is also warranted.

  13. Fundamental study on the characteristics of a radiophotoluminescence glass dosemeter with no energy compensation filter for measuring patient entrance doses in cardiac interventional procedures.

    PubMed

    Kato, Mamoru; Chida, Koichi; Moritake, Takashi; Koguchi, Yasuhiro; Sato, Tadaya; Oosaka, Hajime; Tosa, Tetsuo; Kadowaki, Ken

    2014-12-01

    Cardiac interventional procedures have been increasing year by year. However, radiation skin injuries have been still reported. There is a necessity to measure the patient entrance skin dose (ESD), but an accurate dose measurement method has not been established. To measure the ESD, a lot of radiophotoluminescence dosemeters (RPLDs) provide an accurate measurement of the direct actual ESD at the points they are arrayed. The purpose of this study was to examine the characteristics of RPLD to measure the ESD. As a result, X-ray permeable RPLD (with no tin filter) did not interfere with the percutaneous coronary intervention procedure. The RPLD also had good fundamental performance characteristics. Although the RPLD had a little energy dependence, it showed excellent dose and dose-rate linearity, and good angular dependence. In conclusion, by calibrating the energy dependence, RPLDs are useful dosemeter to measure the ESD in cardiac intervention. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Characteristics of electromagnetic interference generated by arc discharges. [in spacecraft

    NASA Technical Reports Server (NTRS)

    Leung, Philip

    1986-01-01

    Electromagnetic interference (EMI) signatures resulting from arc discharges are characterized, and the effects of electrostatic discharges (ESDs) on the design of spacecraft systems are investigated. EMI characterization experiments were performed on Mylar, Teflon, Kapton, fused silica, and fiberglass in a vacuum chamber with acrylic walls; the experimental design and procedures are described. Discharge current pulses and RF spectra generated by the sample materials are examined. The relation between the magnitude of EMI generated during an ESD event and the material, environment, and geometry is studied. The solar-array/plasma interaction is analyzed; particular attention is given to the rate of discharge as a function of plasma density. The physical mechanisms of ESD-generated EMI are discussed. The data reveal that ESD parameters are dependent on the test environment.

  15. Recent Development of Techniques and Devices in Colorectal Endoscopic Submucosal Dissection

    PubMed Central

    Mizutani, Hiroya; Ono, Satoshi; Ohki, Daisuke; Takeuchi, Chihiro; Yakabi, Seiichi; Kataoka, Yosuke; Saito, Itaru; Sakaguchi, Yoshiki; Minatsuki, Chihiro; Tsuji, Yosuke; Niimi, Keiko; Kodashima, Shinya; Yamamichi, Nobutake; Fujishiro, Mitsuhiro; Koike, Kazuhiko

    2017-01-01

    Colorectal endoscopic submucosal dissection (ESD) is now a well-established endoscopic treatment for early-stage colorectal neoplasms, especially in Asian countries, including Japan. Despite the spread of colorectal ESD, there are still situations in which achieving successful submucosal dissection is difficult. Various novel techniques and devices have been developed to overcome these difficulties, and past reports have shown that some of these strategies can be applied to colorectal ESD. We review several recent developments in the field. The techniques reviewed include the pocket creation method and traction methods and the devices reviewed include the overtube with balloon and electrosurgical knives with water-jet function. These improved techniques and devices can facilitate safer, more reliable ESDs and expand its applicability and acceptability all over the world. PMID:29207854

  16. Spherical agglomerates of pure drug nanoparticles for improved pulmonary delivery in dry powder inhalers

    NASA Astrophysics Data System (ADS)

    Hu, Jun; Dong, Yuancai; Pastorin, Giorgia; Ng, Wai Kiong; Tan, Reginald B. H.

    2013-04-01

    The aim of this study was to produce micron-sized spherical agglomerates of pure drug nanoparticles to achieve improved aerosol performance in dry powder inhalers (DPIs). Sodium cromoglicate was chosen as the model drug. Pure drug nanoparticles were prepared through a bottom-up particle formation process, liquid antisolvent precipitation, and then rapidly agglomerated into porous spherical microparticles by immediate (on-line) spray drying. Nonporous spherical drug microparticles with similar geometric size distribution were prepared by conventional spray drying of the aqueous drug solution, which together with the mechanically micronized drug particles were used as the control samples. The three samples were characterized by field emission scanning electron microscopy, laser diffraction, Brunauer-Emmett-Teller analysis, density measurement, powder X-ray diffraction, and in vitro aerosol deposition measurement with a multistage liquid impinger. It was found that drug nanoparticles with a diameter of 100 nm were precipitated and agglomerated into highly porous spherical microparticles with a volume median diameter ( D 50 %) of 2.25 ± 0.08 μm and a specific surface area of 158.63 ± 3.27 m2/g. In vitro aerosol deposition studies showed the fine particle fraction of such spherical agglomerates of drug nanoparticles was increased by more than 50 % in comparison with the control samples, demonstrating significant improvements in aerosol performance. The results of this study indicated the potential of the combined particle engineering process of liquid antisolvent precipitation followed by immediate (on-line) spray drying in the development of novel DPI drug products with improved aerosol performance.

  17. A characterization study of a hydroxylated polycrystalline tin oxide surface

    NASA Technical Reports Server (NTRS)

    Hoflund, Gar B.; Grogan, Austin L., Jr.; Asbury, Douglas A.; Schryer, David R.

    1989-01-01

    In this study Auger electron spectroscopy, electron spectroscopy for chemical analysis (ESCA) and electron-stimulated desorption (ESD) have been used to examine a polycrystalline tin oxide surface before and after annealing in vacuum at 500 C. Features due to surface hydroxyl groups are present in both the ESCA and ESD spectra, and ESD shows that several chemical states of hydrogen are present. Annealing at 500 C causes a large reduction in the surface hydrogen concentration but not complete removal.

  18. Interaction of Highly Underexpanded Jets with Simulated Lunar Surfaces

    NASA Technical Reports Server (NTRS)

    Stitt, Leonard E.

    1961-01-01

    Pressure distributions and erosion patterns on simulated lunar surfaces (hard and soft) and interference effects between the surface and two representative lunar vehicles (cylindrical and spherical) were obtained with cold-air jets at various descent heights and nozzle total-pressure ratios up to 288,000. Surface pressure distributions were dependent on both nozzle area ratio and, nozzle contour. Peak pressures obtained with a sonic nozzle agreed closely with those predicted theoretically for a near-sonic jet expanding into a vacuum. Short bell-shaped nozzles gave annular pressure distributions; the low center pressure resulted from the coalescence of shocks that originated within the nozzle. The high surface pressures were contained within a circle whose diameter was about 16 throat diameters, regardless of nozzle area ratio or contour. The peak pressure increased rapidly as the vehicle approached the surface; for example, at a descent height of 40 throat diameters the peak pressure was 0.4 percent of the chamber pressure, but increased to 6 percent at 13 throat diameters. The exhaust jet eroded a circular concave hole in white sand at descent heights from about 200 to 600 throat diameters. The hole diameter was about 225 throat diameters, while the depth was approximately 60 throat diameters. The sand particles, which formed a conical sheet at a semivertex angle of 50 deg, appeared to follow a ballistic trajectory and at no time struck the vehicle. An increase in pressure was measured on the base of the cylindrical lunar vehicle when it approached to within 14 throat diameters of the hard, flat surface. No interference effects were noted between the spherical model and the surface to descent heights as low as 8 throat diameters.

  19. Aberration compensation between anterior and posterior corneal surfaces after Small incision lenticule extraction and Femtosecond laser-assisted laser in-situ keratomileusis.

    PubMed

    Li, Xiaojing; Wang, Yan; Dou, Rui

    2015-09-01

    To investigate the aberration compensation between anterior and posterior corneal surfaces after SMILE and FS-LASIK. Fifty-five subjects (55 eyes) undergoing SMILE and 51 subjects (51 eyes) undergoing FS-LASIK were enrolled in this study. Wavefront aberrations of anterior and posterior corneal surfaces and the whole cornea at 6 mm in diameter were measured using a Scheimpflug Camera preoperatively and one, three and 6 months postoperatively. The compensation factor (CF), where CF = 1 - (aberration of the whole cornea/aberration of anterior corneal surface), was calculated. Spherical aberration of the posterior surface and the whole cornea remained stable after SMILE. However, spherical aberration of posterior surface increased significantly at 6 months in the FS-LASIK group. The total higher-order aberration (tHOA) of the anterior surface and the whole cornea was lower at 6 months than at one and 3 months (p = 0.001 and 0.001, respectively) in the FS-LASIK group. Meanwhile, in the SMILE group, no significant difference in tHOA was found between various postoperative time points. There were significant decreases in the CF of tHOA compared with preoperative values in both groups. The CF of spherical aberration reduced significantly in both groups at 3 and 6 mm in diameter one, three and 6 months postoperatively. Significant decreases in the CF of vertical coma were found at three and 6 months postoperatively in the FS-LASIK group compared with preoperative values at 6 mm in diameter (p = 0.021 and 0.008, respectively). The change in CF (ΔCF) of spherical aberration was smaller in the SMILE group than in the FS-LASIK group at one and 3 months postoperatively (p = 0.003 and p < 0.0001, respectively). The ΔCF of spherical aberration was significantly lower in moderately myopic subjects than in subjects with high myopia at 1 month in the SMILE group (p = 0.041) and at one, three and 6 months in the FS-LASIK group (p = 0.014, 0.020, and 0.004, respectively). The posterior corneal surface plays an important role in compensating for spherical aberration of the anterior corneal surface. The compensation mechanisms of spherical aberration and higher-order aberration between anterior and posterior corneal surfaces were disrupted by the SMILE and the FS-LASIK procedures. The change in the CF of spherical aberration was smaller in the SMILE group compared with the FS-LASIK group, especially in subjects with high myopia. © 2015 The Authors Ophthalmic & Physiological Optics © 2015 The College of Optometrists.

  20. Does endothelial cell density correlate with corneal diameter in a group of young adults?

    PubMed

    Giasson, Claude J; Gosselin, Lucie; Masella, Aviva; Forcier, Pierre

    2008-07-01

    In children, but not in the elderly, an association exists between corneal diameter and endothelial cell density (ECD). We tested whether such an association also held true in young adults. The eyes of 35 healthy subjects (mean age, 23.1 +/- 3.1 years) were photographed by using a video camera and a noncontact endothelial microscope. Both sets of images were analyzed with image software and the contour method to measure corneal diameter, ECD, and endothelial coefficients. Axial lengths, refractive errors, and corneal curvatures were measured by using an A-scan ultrasonic biometer and kerato-refractometer. Measurements, averaged for the right and left eyes, were analyzed depending on (1) use of contact lenses, (2) ametropia, and on whether (3) axial length or (4) corneal diameter was above or below group means. Differences were tested for statistical significance with independent t tests and association with the Pearson correlation coefficient. ECD, corneal diameter, and spherical equivalent refraction were 3022 +/- 262 cells/mm2, 12.0 +/- 0.5 mm, and -3.1 +/- 2.5 D, respectively. The only significant differences between wearers and nonwearers of contact lenses were the spherical refractive equivalent and axial length. There was no correlation between ECD and corneal diameter or axial length. As opposed to previously reported results in children, but as found in the elderly, there is no correlation between ECD and corneal diameter in young adults. Therefore, corneal size cannot be considered a determinant of ECD in young adults.

  1. Fabrication of an Optical Fiber Micro-Sphere with a Diameter of Several Tens of Micrometers.

    PubMed

    Yu, Huijuan; Huang, Qiangxian; Zhao, Jian

    2014-06-25

    A new method to fabricate an integrated optical fiber micro-sphere with a diameter within 100 µm, based on the optical fiber tapering technique and the Taguchi method is proposed. Using a 125 µm diameter single-mode (SM) optical fiber, an optical fiber taper with a cone angle is formed with the tapering technique, and the fabrication optimization of a micro-sphere with a diameter of less than 100 µm is achieved using the Taguchi method. The optimum combination of process factors levels is obtained, and the signal-to-noise ratio (SNR) of three quality evaluation parameters and the significance of each process factors influencing them are selected as the two standards. Using the minimum zone method (MZM) to evaluate the quality of the fabricated optical fiber micro-sphere, a three-dimensional (3D) numerical fitting image of its surface profile and the true sphericity are subsequently realized. From the results, an optical fiber micro-sphere with a two-dimensional (2D) diameter less than 80 µm, 2D roundness error less than 0.70 µm, 2D offset distance between the micro-sphere center and the fiber stylus central line less than 0.65 µm, and true sphericity of about 0.5 µm, is fabricated.

  2. Endoscopic transgastric drainage of a gastric wall abscess after endoscopic submucosal dissection

    PubMed Central

    Dohi, Osamu; Dohi, Moyu; Inoue, Ken; Gen, Yasuyuki; Jo, Masayasu; Tokita, Kazuhiko

    2014-01-01

    A 63-year-old woman was referred to our hospital for further examination because of an incidental finding of early gastric cancer. Endoscopic submucosal dissection (ESD) was successfully performed for complete resection of the tumor. On the first post-ESD day, the patient suddenly complained of abdominal pain after an episode of vomiting. Abdominal computed tomography (CT) showed delayed perforation after ESD. The patient was conservatively treated with an intravenous proton pump inhibitor and antibiotics. On the fifth post-ESD day, CT revealed a gastric wall abscess in the gastric body. Gastroscopy revealed a gastric fistula at the edge of the post-ESD ulcer, and pus was found flowing into the stomach. An intradrainage stent and an extradrainage nasocystic catheter were successfully inserted into the abscess for endoscopic transgastric drainage. After the procedure, the clinical symptoms and laboratory test results improved quickly. Two months later, a follow-up CT scan showed no collection of pus. Consequently, the intradrainage stent was removed. Although the gastric wall abscess recurred 2 wk after stent removal, it recovered soon after endoscopic transgastric drainage. Finally, after stent removal and oral antibiotic treatment for 1 mo, no recurrence of the gastric wall abscess was found. PMID:24574787

  3. Characterisation of soils under long-term crop cultivation without fertilisers: a case study in Japan.

    PubMed

    Nakatsuka, Hiroko; Tamura, Kenji

    2016-01-01

    Certain farms in Japan, namely unfertilised farms (UFs), have been able to maintain high productivity for over 40 years without applying fertilisers or composts. This study aimed to characterise the physicochemical, biological and micromorphological properties of soil in UFs compared with control farms in Eniwa and Nariita and to identify characteristics that are associated with crop productivity. In UFs, no plough pan was observed. The thickness of the effective soil depth (ESD) of UFs was greater than that of CFs. The concentrations of soil organic carbon, total nitrogen and nitrate-nitrogen in ESD of UFs were higher than those in ESD of CFs. Soil microstructure observations indicated the strong development of a granular microstructure with large amounts of void space and a high fractal dimension in both surface and subsoil horizons of UFs. Dry yield had a strong correlation with ESD thickness and fractal dimension of voids. Thus, the management of unfertilised cultivation promoted the development of soil aggregation in both A and B horizons. The increase in ESD, soil pore spaces and complexity with the development of subsoil structure improved the productivity of unfertilised cultivation.

  4. Retrospective study

    PubMed Central

    Lu, Chao; Lv, Xueyou; Lin, Yiming; Li, Dejian; Chen, Lihua; Ji, Feng; Li, Youming; Yu, Chaohui

    2016-01-01

    Abstract Conventional forceps biopsy (CFB) is the most popular way to screen for gastric epithelial neoplasia (GEN) and adenocarcinoma of gastric epithelium. The aim of this study was to compare the diagnostic accuracy between conventional forceps biopsy and endoscopic submucosal dissection (ESD). Four hundred forty-four patients who finally undertook ESD in our hospital were enrolled from Jan 1, 2009 to Sep 1, 2015. We retrospectively assessed the characteristics of pathological results of CFB and ESD. The concordance rate between CFB and ESD specimens was 68.92% (306/444). Men showed a lower concordance rate (63.61% vs 79.33%; P = 0.001) and concordance patients were younger (P = 0.048). In multivariate analysis, men significantly had a lower concordance rate (coefficient −0.730, P = 0.002) and a higher rate of pathological upgrade (coefficient −0.648, P = 0.015). Locations of CFB did not influence the concordance rate statistically. The concordance rate was relatively high in our hospital. According to our analysis, old men plus gastric fundus or antrum of CFB were strongly suggested to perform ESD if precancerous lesions were found. And young women with low-grade intraepithelial neoplasia could select regular follow-up. PMID:27472723

  5. Triboelectric Charging in Simulated Mars Environment

    NASA Technical Reports Server (NTRS)

    Lee, R.; Barile, R.

    1999-01-01

    Triboelectric charging of nonconducting materials followed by sudden electrostatic discharge (ESD) can damage electronic equipment and become ignition hazard to combustible materials. Mars atmosphere has near zero humidity and therefore natural charge bleeding to surroundings is anticipated to be limited. Potential mitigation of ESD problems has been conjectured based upon strong extraterrestrial radiation on Mars compared to earth. A hypothesis was formulated that ESD problem is less significant in simulated Mars condition since strong radiation and presence of argon will generate an ionized environment; this will be conducive to rapid bleeding of static charge into the surroundings.

  6. Comparison of detectability in step-and-shoot mode and continuous mode digital tomosynthesis systems

    NASA Astrophysics Data System (ADS)

    Lee, Changwoo; Han, Minah; Baek, Jongduk

    2017-03-01

    Digital tomosynthesis system has been widely used in chest, dental, and breast imaging. Since the digital tomosynthesis system provides volumetric images from multiple projection data, structural noise inherent in X-ray radiograph can be reduced, and thus signal detection performance is improved. Currently, tomosynthesis system uses two data acquisition modes: step-and-shoot mode and continuous mode. Several studies have been conducted to compare the system performance of two acquisition modes with respect to spatial resolution and contrast. In this work, we focus on signal detectability in step-and-shoot mode and continuous mode. For evaluation, uniform background is considered, and eight spherical objects with diameters of 0.5, 0.8, 1, 2, 3, 5, 8, 10 mm are used as signals. Projection data with and without spherical objects are acquired in step-and-shoot mode and continuous mode, respectively, and quantum noise are added. Then, noisy projection data are reconstructed by FDK algorithm. To compare the detection performance of two acquisition modes, we calculate task signal-to-noise ratio (SNR) of channelized Hotelling observer with Laguerre-Gauss channels for each spherical object. While the task-SNR values of two acquisition modes are similar for spherical objects larger than 1 mm diameter, step-and-shoot mode yields higher detectability for small signal sizes. The main reason of this behavior is that small signal is more affected by X-ray tube motion blur than large signal. Our results indicate that it is beneficial to use step-and-shoot data acquisition mode to improve the detectability of small signals (i.e., less than 1 mm diameter) in digital tomosynthesis systems.

  7. CO2 insufflation versus air insufflation for endoscopic submucosal dissection: A meta-analysis of randomized controlled trials.

    PubMed

    Li, Xuan; Dong, Hao; Zhang, Yifeng; Zhang, Guoxin

    2017-01-01

    Carbon dioxide (CO2) insufflation is increasingly used for endoscopic submucosal dissection (ESD) owing to the faster absorption of CO2 as compared to that of air. Studies comparing CO2 insufflation and air insufflation have reported conflicting results. This meta-analysis is aimed to assess the efficacy and safety of use of CO2 insufflation for ESD. Clinical trials of CO2 insufflation versus air insufflation for ESD were searched in PubMed, Embase, the Cochrane Library and Chinese Biomedical Literature Database. We performed a meta-analysis of all randomized controlled trials (RCTs). Eleven studies which compared the use of CO2 insufflation and air insufflation, with a combined study population of 1026 patients, were included in the meta-analysis (n = 506 for CO2 insufflation; n = 522 for air insufflation). Abdominal pain and VAS scores at 6h and 24h post-procedure in the CO2 insufflation group were significantly lower than those in the air insufflation group, but not at 1h and 3h after ESD. The percentage of patients who experienced pain 1h and 24h post-procedure was obviously decreased. Use of CO2 insufflation was associated with lower VAS scores for abdominal distention at 1h after ESD, but not at 24h after ESD. However, no significant differences were observed with respect to postoperative transcutaneous partial pressure carbon dioxide (PtcCO2), arterial blood carbon dioxide partial pressure (PaCO2), oxygen saturation (SpO2%), abdominal circumference, hospital stay, white blood cell (WBC) counts, C-Reactive protein (CRP) level, dosage of sedatives used, incidence of dysphagia and other complications. Use of CO2 insufflation for ESD was safe and effective with regard to abdominal discomfort, procedure time, and the residual gas volume. However, there appeared no significant differences with respect to other parameters namely, PtcCO2, PaCO2, SpO2%, abdominal circumference, hospital stay, sedation dosage, complications, WBC, CRP, and dysphagia.

  8. A pilot study using an infrared imaging system in prevention of post-endoscopic submucosal dissection ulcer bleeding.

    PubMed

    Yoshida, Yukinaga; Matsuda, Koji; Tamai, Naoto; Yoshizawa, Kai; Nikami, Toshiki; Ishiguro, Haruya; Tajiri, Hisao

    2014-01-01

    Endoscopic submucosal dissection (ESD) for superficial gastric neoplasm is a curative method. The aim of this study was to detect potential nonbleeding visible vessels (NBVVs) by using an infrared imaging (IRI) system. A total of 24 patients (25 lesions) were consecutively enrolled between March 2010 and December 2010. The day after ESD, endoscopist A (K.M.), who was blinded to the actual procedure of ESD, performed esophagogastroduodenoscopy (EGD) of the post-ESD ulcer base using the IRI system. Endoscopist A marked gray/blue points in the hard-copy images with the IRI system. After the first procedure, endoscopist B (Y.Y.), who was blinded to the results recorded by endoscopist A, performed a second EGD with white light endoscopy and administered water-jet pressure with the maximum level of an Olympus flushing pump onto the post-ESD ulcer base. This test can cause iatrogenic bleeding via application of pressure to NBVV in the post-ESD ulcer. The IRI system detected 58 gray points and 71 blue points. The post-ESD ulcer was divided into the central area and the peripheral area. There were 14 gray points (24 %) in the central area and 44 gray points (76 %) in the peripheral area. There were 19 blue points (27 %) in the central area and 52 blue points (73 %) in the peripheral area. There was no significant difference when comparing the distribution of gray points and blue points. Bleeding occurred with a water-jet pressure in 11 of 58 gray points and in none of the blue points (P = 0.000478). Among the gray points, bleeding in response to a water-jet pressure occurred in 2 points in the central area and in 9 points in the peripheral area. The IRI system detects visible vessels (VVs) that are in no need of coagulation as blue points, and VVs have a potential risk of bleeding as gray points.

  9. Endoscopic submucosal dissection vs endoscopic mucosal resection for early gastric cancer: A meta-analysis.

    PubMed

    Facciorusso, Antonio; Antonino, Matteo; Di Maso, Marianna; Muscatiello, Nicola

    2014-11-16

    To compare endoscopic submucosal dissection (ESD) and endoscopic mucosal resection (EMR) for early gastric cancer (EGC). Computerized bibliographic search was performed on PubMed/Medline, Embase, Google Scholar and Cochrane library databases. Quality of each included study was assessed according to current Cochrane guidelines. Primary endpoints were en bloc resection rate and histologically complete resection rate. Secondary endpoints were length of procedure, post-treatment bleeding, post-procedural perforation and recurrence rate. Comparisons between the two treatment groups across all the included studies were performed by using Mantel-Haenszel test for fixed-effects models (in case of low heterogeneity) or DerSimonian and Laird test for random-effects models (in case of high heterogeneity). Ten retrospective studies (8 full text and 2 abstracts) were included in the meta-analysis. Overall data on 4328 lesions, 1916 in the ESD and 2412 in the EMR group were pooled and analyzed. The mean operation time was longer for ESD than for EMR (standardized mean difference 1.73, 95%CI: 0.52-2.95, P = 0.005) and the "en bloc" and histological complete resection rates were significantly higher in the ESD group [OR = 9.69 (95%CI: 7.74-12.13), P < 0.001 and OR = 5.66, (95%CI: 2.92-10.96), P < 0.001, respectively]. As a consequence of its greater radicality, ESD provided lower recurrence rate [OR = 0.09, (95%CI: 0.05-0.17), P < 0.001]. Among complications, perforation rate was significantly higher after ESD [OR = 4.67, (95%CI, 2.77-7.87), P < 0.001] whereas the bleeding incidences did not differ between the two techniques [OR = 1.49 (0.6-3.71), P = 0.39]. In the endoscopic therapy of EGC, ESD showed a superior efficacy but higher complication rate with respect to EMR.

  10. Endoscopic submucosal dissection vs endoscopic mucosal resection for early gastric cancer: A meta-analysis

    PubMed Central

    Facciorusso, Antonio; Antonino, Matteo; Di Maso, Marianna; Muscatiello, Nicola

    2014-01-01

    AIM: To compare endoscopic submucosal dissection (ESD) and endoscopic mucosal resection (EMR) for early gastric cancer (EGC). METHODS: Computerized bibliographic search was performed on PubMed/Medline, Embase, Google Scholar and Cochrane library databases. Quality of each included study was assessed according to current Cochrane guidelines. Primary endpoints were en bloc resection rate and histologically complete resection rate. Secondary endpoints were length of procedure, post-treatment bleeding, post-procedural perforation and recurrence rate. Comparisons between the two treatment groups across all the included studies were performed by using Mantel-Haenszel test for fixed-effects models (in case of low heterogeneity) or DerSimonian and Laird test for random-effects models (in case of high heterogeneity). RESULTS: Ten retrospective studies (8 full text and 2 abstracts) were included in the meta-analysis. Overall data on 4328 lesions, 1916 in the ESD and 2412 in the EMR group were pooled and analyzed. The mean operation time was longer for ESD than for EMR (standardized mean difference 1.73, 95%CI: 0.52-2.95, P = 0.005) and the “en bloc” and histological complete resection rates were significantly higher in the ESD group [OR = 9.69 (95%CI: 7.74-12.13), P < 0.001 and OR = 5.66, (95%CI: 2.92-10.96), P < 0.001, respectively]. As a consequence of its greater radicality, ESD provided lower recurrence rate [OR = 0.09, (95%CI: 0.05-0.17), P < 0.001]. Among complications, perforation rate was significantly higher after ESD [OR = 4.67, (95%CI, 2.77-7.87), P < 0.001] whereas the bleeding incidences did not differ between the two techniques [OR = 1.49 (0.6-3.71), P = 0.39]. CONCLUSION: In the endoscopic therapy of EGC, ESD showed a superior efficacy but higher complication rate with respect to EMR. PMID:25400870

  11. Locoregional mitomycin C injection for esophageal stricture after endoscopic submucosal dissection.

    PubMed

    Machida, H; Tominaga, K; Minamino, H; Sugimori, S; Okazaki, H; Yamagami, H; Tanigawa, T; Watanabe, K; Watanabe, T; Fujiwara, Y; Arakawa, T

    2012-06-01

    This prospective study aimed to evaluate the feasibility and safety of locoregional mitomycin C (MMC) injection to treat refractory esophageal strictures after endoscopic submucosal dissection (ESD) for superficial esophageal carcinoma. Patients with dysphagia and strictures that were refractory to repeated endoscopic balloon dilation (EBD) were eligible. After EBD, MMC was injected into the dilated site. Between June 2009 and August 2010, five patients were recruited. The treatment was performed once in two patients and twice in three patients with recurrent dysphagia or restenosis. In all patients, passing a standard endoscope through the site was easy and the dysphagia grade improved (grade 3→1 in 3 patients, grade 4→2 in 2 patients). No serious complications were noted. During the observation period of 4.8 months, neither recurrent dysphagia nor re-stricture appeared in any of the patients. The combination of locoregional MMC injections and EBD is feasible and safe for the treatment of esophageal strictures after ESD.Recently, endoscopic submucosal dissection (ESD) has been developed and accepted as a new endoscopic treatment for gastrointestinal tumors. ESD is a promising treatment for superficial esophageal carcinoma (SEC), and it has a reliable en bloc resection rate. However, the application of ESD for widespread lesions is challenging because of the high risk of the development of severe strictures, which lead to a low quality of life after ESD. Although endoscopic balloon dilation (EBD) is effective for benign strictures, it needs to be performed frequently until the dysphagia disappears 1. Mitomycin C (MMC), which is a chemotherapeutic agent derived from some Streptomyces species 2, reduces scar formation when topically applied to a surgical lesion. MMC has been applied to treat strictures in a variety of anatomical locations, including a variety of organs 3. The aim of this study was to prospectively evaluate both the feasibility and the safety of locoregional MMC injection therapy in patients with refractory esophageal strictures after ESD for SEC. © Georg Thieme Verlag KG Stuttgart · New York.

  12. EMR is not inferior to ESD for early Barrett’s and EGJ neoplasia: An extensive review on outcome, recurrence and complication rates

    PubMed Central

    Komeda, Yoriaki; Bruno, Marco; Koch, Arjun

    2014-01-01

    Background and study aims In recent years, it has been reported that early Barrett’s and esophagogastric junction (EGJ) neoplasia can be effectively and safely treated using endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD). Multiband mucosectomy (MBM) appears to be the safest EMR method. The aim of this systematic review is to assess the safety and efficacy of MBM compared with ESD for the treatment of early neoplasia in Barrett’s or at the EGJ. Methods A literature review of studies published up to May 2013 on EMR and ESD for early Barrett’s esophagus (BE) neoplasia and adenocarcinoma at the EGJ was performed through MEDLINE, EMBASE and the Cochrane Library. Results on outcome parameters such as number of curative resections, complications and procedure times are compared and reported. Results A total of 16 studies met the inclusion criteria for analysis in this study. There were no significant differences in recurrence rates when comparing EMR (10/380, 2.6 %) to ESD (1/333, 0.7 %) (OR 8.55; 95 %CI, 0.91 – 80.0, P = 0.06). All recurrences after EMR were treated with additional endoscopic resection. The risks of delayed bleeding, perforation and stricture rates in both groups were similar. The procedure was considerably less time-consuming in the EMR group (mean time 36.7 min, 95 %CI, 34.5 – 38.9) than in the ESD group (mean time 83.3 min, 95 %CI, 57.4 – 109.2). Conclusions The MBM technique for EMR is as effective as ESD when comparing outcomes related to recurrence and complication rates for the treatment of early Barrett’s or EGJ neoplasia. The MBM technique is considerably less time-consuming. PMID:26135261

  13. Randomized comparative evaluation of endoscopic submucosal dissection self-learning software in France and Japan.

    PubMed

    Pioche, Mathieu; Rivory, Jérôme; Nishizawa, Toshihiro; Uraoka, Toshio; Touzet, Sandrine; O'Brien, Marc; Saurin, Jean-Christophe; Ponchon, Thierry; Denis, Angélique; Yahagi, Naohisa

    2016-12-01

    Background and study aim: Endoscopic submucosal dissection (ESD) is currently the reference method to achieve an en bloc resection for large lesions; however, the technique is difficult and risky, with a long learning curve. In order to reduce the morbidity, training courses that use animal models are recommended. Recently, self-learning software has been developed to assist students in their training. The aim of this study was to evaluate the impact of this tool on the ESD learning curve. Methods: A prospective, randomized, comparative study enrolled 39 students who were experienced in interventional endoscopy. Each student was randomized to one of two groups and performed 30 ESDs of 30 mm standardized lesions in a bovine colon model. The software group used the self-learning software whereas the control group only observed an ESD procedure video. The primary outcome was the rate of successful ESD procedures, defined as complete en bloc resection without any perforation and performed in less than 75 minutes. Results: A total of 39 students performed 1170 ESDs. Success was achieved in 404 (70.9 %) in the software group and 367 (61.2 %) in the control group ( P  = 0.03). Among the successful procedures, there were no significant differences between the software and control groups in terms of perforation rate (22 [4.0 %] vs. 29 [5.1 %], respectively; P  = 0.27) and mean (SD) procedure duration (34.1 [13.4] vs. 32.3 [14.0] minutes, respectively; P  = 0.52). For the 30th procedure, the rate of complete resection was superior in the software group (84.2 %) compared with the control group (50.0 %; P  = 0.01). Conclusion: ESD self-learning software was effective in improving the quality of resection compared with a standard teaching method using procedure videos. This result suggests the benefit of incorporating such software into teaching programs. © Georg Thieme Verlag KG Stuttgart · New York.

  14. An experimental study of the reflection from spherical and flat ended cylindrical targets suitable for fetal Doppler performance assessment.

    PubMed

    Preston, R C; Bond, A D

    1997-01-01

    The performance of small-diameter targets suitable for use as oscillating targets for testing the sensitivity of Doppler fetal heartbeat detectors has been systematically studied. Experimental results are presented in the 1.6-3.0 MHz frequency range for the plane-wave reflection loss for a total of 16 targets: spherical balls made of stainless steel; hemispherical-ended rods made of PTFE; and flat-ended rods made of stainless steel, PTFE, polycarbonate, and tungsten carbide. Results show that the fine-structure variation of reflection loss with frequency is greatest in the case of spherical ball targets and least for flat-ended targets. It has been shown that, providing care is taken during manufacture, the reflection loss from a flat-ended target can be predicted using a simple theory based on a plane disc reflector. Tungsten carbide targets consisting of a long rod with a diameter of 1.6 mm tapered down to a cylindrical flat end with a diameter of 0.4, 0.5, and 0.6 mm have been shown to provide reflection losses of between 60 and 40 dB, and to have a smooth variation of reflection loss with frequency. They can also be manufactured in a form that allows no significant interference from the supporting structure and, therefore, are ideal targets to meet the requirements of International Electrotechnical Commission 1266:1995.

  15. Severe splenic rupture after colorectal endoscopic submucosal dissection

    PubMed Central

    Herreros de Tejada, Alberto; Giménez-Alvira, Luis; Van den Brule, Enrique; Sánchez-Yuste, Rosario; Matallanos, Pilar; Blázquez, Esther; Calleja, Jose L; Abreu, Luis E

    2014-01-01

    Splenic rupture (SR) after colonoscopy is a very rare but potentially serious complication. Delayed diagnosis is common, and may increase morbidity and mortality associated. There is no clear relation between SR and difficult diagnostic or therapeutic procedures, but it has been suggested that loop formation and excessive torquing might be risk factors. This is a case of a 65-year-old woman who underwent endoscopic submucosal dissection (ESD) for lateral spreading tumor in the descending colon, and 36 h afterwards presented symptoms and signs of severe hypotension due to SR. Standard splenectomy was completed and the patient recovered uneventfully. Colorectal ESD is usually a long and position-demanding technique, implying torquing and loop formation. To our knowledge this is the first case of SR after colorectal ESD reported in the literature. Endoscopists performing colorectal ESD in the left colon must be aware of this potential complication. PMID:25071360

  16. Development of Energy-Saving Devices for a 20,000DWT River-Sea Bulk Carrier

    NASA Astrophysics Data System (ADS)

    Chen, Kunpeng; Gao, Yuling; Huang, Zhenping; Dong, Guoxiang

    2018-05-01

    A reduction of fuel consumption and an increase in efficiency are currently required for river-sea bulk carriers. Pre-swirl and ducted stators are widely used devices in the industry and efficiency gains can be obtained for single-screw and twin-screw vessels. Based on the hydrodynamic characteristics of the 20,000DWT river-sea bulk carrier, in this study, we proposed, designed, and tested a series of pre-swirl energy-saving devices (ESDs). The experimental results demonstrate that the proposed ESDs improved the propulsive efficiency and reduced the delivered power. The results confirm the success of our ESD for the 20,000DWT river-sea bulk carrier. We validated the role of Reynolds-averaged Navier-Stokes (RANS) computational fluid dynamics (CFD) in the twin-skeg river-sea vessel ESD design and found the circumferential arrangement and number of stators to be important factors in the design process.

  17. Critical Review of the ECSS-E-ST-20-07C ESD Test Set-Up for Testing Spacecraft Equipment

    NASA Astrophysics Data System (ADS)

    Pelissou, P.; Daout, B.; Romero, C.; Wolf, K.-F. J.

    2016-05-01

    Satellite equipment needs to be immune to electrostatic discharges (ESD) likely to occur in flight. Testing the susceptibility against ESD on spacecraft equipment is therefore an important part of the EMC test program. The test method according to ECSS-E-ST- 20-07C [1], which is commonly used in space industry, leaves undesirable degrees of freedom on how the test is performed, which in turn has an influence on the injected current and therefore on the test results. Because of the indirect coupling of ESD to circuits, the current waveform applied during the test and its repeatability are of high importance. In the frame of an ESTEC research contract (4000109887/13/NL/GLC), a critical review of the ECSS-E-ST-20-07C is performed to identify the influence factors which have an impact on the test repeatability.

  18. Acoustic field of a wedge-shaped section of a spherical cap transducer

    NASA Astrophysics Data System (ADS)

    Ketterling, Jeffrey A.

    2003-12-01

    The acoustic pressure field at an arbitrary point in space is derived for a wedge-shaped section of a spherical cap transducer using the spatial impulse response (SIR) method. For a spherical surface centered at the origin, a wedge shape is created by taking cuts in the X-Y and X-Z planes and removing the smallest surface component. Analytic expressions are derived for the SIR based on spatial location. The expressions utilize the SIR solutions for a spherical cap transducer [Arditi et al., Ultrason. Imaging 3, 37-61 (1981)] with additional terms added to account for the reduced surface area of the wedge. Results from the numerical model are compared to experimental measurements from a wedge transducer with an 8-cm outer diameter and 9-cm geometric focus. The experimental and theoretical -3-dB beamwidths agreed to within 10%+/-5%. The SIR model for a wedge-shaped transducer is easily extended to other spherically curved transducer geometries that consist of combinations of wedge sections and spherical caps.

  19. Acoustic field of a wedge-shaped section of a spherical cap transducer.

    PubMed

    Ketterling, Jeffrey A

    2003-12-01

    The acoustic pressure field at an arbitrary point in space is derived for a wedge-shaped section of a spherical cap transducer using the spatial impulse response (SIR) method. For a spherical surface centered at the origin, a wedge shape is created by taking cuts in the X-Y and X-Z planes and removing the smallest surface component. Analytic expressions are derived for the SIR based on spatial location. The expressions utilize the SIR solutions for a spherical cap transducer [Arditi et al., Ultrason. Imaging 3, 37-61 (1981)] with additional terms added to account for the reduced surface area of the wedge. Results from the numerical model are compared to experimental measurements from a wedge transducer with an 8-cm outer diameter and 9-cm geometric focus. The experimental and theoretical -3-dB beamwidths agreed to within 10% +/- 5%. The SIR model for a wedge-shaped transducer is easily extended to other spherically curved transducer geometries that consist of combinations of wedge sections and spherical caps.

  20. Risk factors for under-diagnosis of gastric intraepithelial neoplasia and early gastric carcinoma in endoscopic forceps biopsy in comparison with endoscopic submucosal dissection in Chinese patients.

    PubMed

    Xu, Guifang; Zhang, Weijie; Lv, Ying; Zhang, Bin; Sun, Qi; Ling, Tingsheng; Zhang, Xiaoqi; Zhou, Zhihua; Wang, Lei; Huang, Qin; Zou, Xiaoping

    2016-07-01

    Differences in pathologic diagnosis between endoscopic forceps biopsy (EFB) and endoscopic submucosal dissection (ESD) for gastric intraepithelial neoplasia (GIN) and early gastric carcinoma (EGC) in Chinese patients remain unknown. The aim of the study was to investigate risk factors for under-diagnosed pathology in initial EFB, compared to final ESD. We reviewed endoscopic and histopathologic findings for tumor location, size, macroscopic pattern, nodularity, erythema, erosion, GIN (low and high grade), and EGC diagnosed with the WHO criteria. Differences in those features between EFB and ESD were compared and risk factors for under-diagnosis by EFB were analyzed. Although concordant in most (74.9 %) cases between EFBs and ESDs, pathological diagnoses in 57 (25.1 %) cases were upgraded in ESDs. Compared to the concordant group, the lesion size ≥2 cm, and depressed and excavated patterns were significantly more frequent in the upgraded group. Further multivariate regression analysis demonstrated the depressed pattern and lesion size ≥2 cm as independent risk factors for upgraded pathology with the odds ratio of 5.778 (95 % confidence interval 2.893-11.542) and 2.535 (95 % confidence interval 1.257-5.111), respectively. Lesion size ≥2.0 cm and the depressed pattern at initial EFB were independent risk factors for pathologic upgrade to advanced diseases in ESD. Therefore, these endoscopic characteristics should be considered together with the initial EFB diagnosis to guide the optimal clinical management of patients with GIN and EGC.

  1. Endoscopic submucosal dissection for superficial esophageal neoplasms using the stag beetle knife.

    PubMed

    Fujinami, H; Hosokawa, A; Ogawa, K; Nishikawa, J; Kajiura, S; Ando, T; Ueda, A; Yoshita, H; Sugiyama, T

    2014-01-01

    Endoscopic submucosal dissection (ESD) is an accepted standard treatment for early gastric cancer but is not widely used in the esophagus because of technical difficulties. To increase the safety of esophageal ESD, we used a scissors-type device called the stag beetle (SB) knife. The aim of this study was to determine the efficacy and safety of ESD using the SB knife. We performed a single-center retrospective, uncontrolled trial. A total of 38 lesions were excised by ESD from 35 consecutive patients who were retrospectively divided into the following two groups according to the type of knife used to perform ESD: the hook knife (hook group) was used in 20 patients (21 lesions), and the SB knife (SB group) was used in 15 patients (17 lesions). We evaluated and compared the operative time, lesion size, en bloc resection rate, pathological margins free rate, and complication rate in both groups. The operative time was shorter in the SB group (median 70.0 minutes [interquartile range, 47.5-87.0]) than in the hook group (92.0 minutes [interquartile range, 63.0-114.0]) (P = 0.019), and the rate of complications in the SB group was 0% compared with 45.0% in the hook group (P = 0.004). However, the lesion size, en bloc resection rate, and pathological margins free rate did not differ significantly between the two groups. In conclusion, ESD using the SB knife was safer than that using a conventional knife for superficial esophageal neoplasms. © 2013 Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.

  2. Delayed bleeding and hemorrhage of mucosal defects after gastric endoscopic submucosal dissection on second-look endoscopy.

    PubMed

    Ono, Shoko; Ono, Masayoshi; Nakagawa, Manabu; Shimizu, Yuichi; Kato, Mototsugu; Sakamoto, Naoya

    2016-04-01

    Although second-look endoscopy is performed within several days after gastric endoscopic submucosal dissection (ESD), there has been no evidence supporting the usefulness of the intervention. We investigated the relationship between delayed bleeding and hemorrhage of mucosal defects after ESD on second-look endoscopy and analyzed risk factors of active bleeding on second-look endoscopy. A total of 441 consecutive ESD cases with gastric cancer or adenoma were retrospectively analyzed. Second-look endoscopy was performed in the morning after the day of ESD. Bleeding of mucosal defects on second-look endoscopy was classified according to the Forrest classification, and active bleeding was defined as Forrest Ia or Ib. Delayed bleeding was defined as hematemesis or melena after second-look endoscopy. A total of 406 second-look endoscopies were performed, and delayed bleeding occurred in 11 patients. The incidence rate of delayed bleeding after second-look endoscopy in patients with Forrest Ia or Ib was significantly higher than that in patients with Forrest IIa, IIb or III (7.69 vs. 2.02 %, p < 0.05). Complication of a histological ulcer, large size of the resected specimen and long ESD procedure time were shown to be risk factors for hemorrhage of mucosal defects after ESD on second-look endoscopy by univariate analysis. Multivariate analysis indicated that only large size of the resected specimen was a risk factor. In a specimen size of >35 mm, the odds ratio of active bleeding on second-look endoscopy was 1.9. Active bleeding of mucosal defects on second-look endoscopy is a risk factor for delayed bleeding.

  3. Photofrin-PDT for gastric cancer in the era of endoscopic submucosal dissection

    NASA Astrophysics Data System (ADS)

    Nishiwaki, Yoshiro; Ikematsu, Yoshito; Tokunaga, Yuuji; Kanai, Toshikazu

    2009-06-01

    Background: Endoscopic mucosal resection (EMR) was originated to treat early gastric cancer (EGC). EMR was suitable for small, mucosal and well-differentiated adenocarcinoma without ulceration. It was difficult to resect larger tumors en bloc by this method. In recent years, a more useful method, endoscopic submuscosal dissection (ESD) has been developed, which enables en bloc resection of large mucosal lesions. On the contrary, photodynamic therapy (PDT) is applicable to submucosal, poorly differentiated, or carcinoma with ulceration. In the era of ESD, we evaluated the value of Photofrin-PDT. Patients & Methods: We applied PDT to 36 patients including three advanced cancers, who had been excluded from EMR (ESD) and were at high risks for surgery or refused surgery. Four EGC patients who had not been cured by EMR (ESD) were included. Our PDT procedure consisted of polyhematoporphyrin ether/ester administration (Photofrin, 2 mg/Kg) and pulsed excimer dye laser irradiation at 630 nm 48 hours (and 96 hours) after sensitization. Results: Complete response (CR) at three months was obtained in 84% (21/25) of mucosal cancer and in 50% (4/8) of submucosal cancer. Although three patients with an advanced cancer improved but were not cured, quality of their life was maintained. There were no serious side effects except skin photosensitivity. Conclusion: Photofrin-PDT should be applied not only EGC patients who are excluded from ESD and have not been cured by ESD with poor risk for surgery, and have high possibilitiy to be cured by PDT, but also advanced cancer patients for local improvement of lesions.

  4. Saltation movement of large spherical particles

    NASA Astrophysics Data System (ADS)

    Chara, Z.; Dolansky, J.; Kysela, B.

    2017-07-01

    The paper presents experimental and numerical investigations of the saltation motion of a large spherical particle in an open channel. The channel bottom was roughed by one layer of glass rods of diameter 6 mm. The plastic spheres of diameter 25.7 mm and density 1160 kgm-3 were fed into the water channel and theirs positions were viewed by a digital camera. Two light sheets were placed above and under the channel, so the flow was simultaneously lighted from the top and the bottom. Only particles centers of which moved through the light sheets were recorded. Using a 2D PIV method the trajectories of the spheres and the velocity maps of the channel flow were analyzed. The Lattice-Boldzmann Method (LBM) was used to simulate the particle motion.

  5. Method of simulating spherical voids for use as a radiographic standard

    DOEpatents

    Foster, Billy E.

    1977-01-01

    A method of simulating small spherical voids in metal is provided. The method entails drilling or etching a hemispherical depression of the desired diameter in each of two sections of metal, the sections being flat plates or different diameter cylinders. A carbon bead is placed in one of the hemispherical voids and is used as a guide to align the second hemispherical void with that in the other plate. The plates are then bonded together with epoxy, tape or similar material and the two aligned hemispheres form a sphere within the material; thus a void of a known size has been created. This type of void can be used to simulate a pore in the development of radiographic techniques of actual voids (porosity) in welds and serve as a radiographic standard.

  6. Tailoring sphere density for high pressure physical property measurements on liquids

    NASA Astrophysics Data System (ADS)

    Secco, R. A.; Tucker, R. F.; Balog, S. P.; Rutter, M. D.

    2001-04-01

    We present a new method of tailoring the density of a sphere for use as a probe in high pressure-temperature physical property experiments on liquids. The method consists of a composite sphere made of an inner, high density, metallic, spherical core and an exterior, low density, refractory, spherical shell or mantle. Micromechanical techniques are used to fabricate the composite sphere. We describe a relatively simple mechanical device that can grind hemispherical recesses as small as 200 μm in diameter in sapphire and as small as 500 μm in diameter in ruby hemispheres. Examples of composite spheres made with a Pt or WC core and Al2O3 shell used in metallic liquids pressurized to 16 GPa and 1900 K are shown.

  7. Inorganic fullerene-like nanoparticles of TiS 2

    NASA Astrophysics Data System (ADS)

    Margolin, Alexander; Popovitz-Biro, Ronit; Albu-Yaron, Ana; Rapoport, Lev; Tenne, Reshef

    2005-08-01

    Inorganic closed-cage nanoparticles of TiS 2 were synthesized using gas-phase synthesis. The reported nanoparticles are perfectly spherical with diameters centered between 60 and 80 nm, consisting from up to 80-100 concentric layers. The nucleation and growth mechanism was proposed for the formation of these nanoparticles. Tribological experiments emphasized the important role played by the spherical shape of the nanoparticles in providing rolling friction with a reduced friction coefficient and wear.

  8. Coherent Backscattering in the Cross-Polarized Channel

    NASA Technical Reports Server (NTRS)

    Mischenko, Michael I.; Mackowski, Daniel W.

    2011-01-01

    We analyze the asymptotic behavior of the cross-polarized enhancement factor in the framework of the standard low-packing-density theory of coherent backscattering by discrete random media composed of spherically symmetric particles. It is shown that if the particles are strongly absorbing or if the smallest optical dimension of the particulate medium (i.e., the optical thickness of a plane-parallel slab or the optical diameter of a spherically symmetric volume) approaches zero, then the cross-polarized enhancement factor tends to its upper-limit value 2. This theoretical prediction is illustrated using direct computer solutions of the Maxwell equations for spherical volumes of discrete random medium.

  9. Spherical powder for retaining thermosetting acrylic resin veneers.

    PubMed

    Tanaka, T; Atsuta, M; Uchiyama, Y; Nakabayashi, N; Masuhara, E

    1978-03-01

    1. Nine different sizes of spherical powder were prepared, and their effectiveness as retentive devices was evaluated against those available commercially. 2. Smaller-diameter spherical powder (No. 5) gave the best results of all retaining devices tested. 3. The physical properties of the resins play an important role in the retentive strength with No. 5 retention beads. The retentive strength was reduced when brittle resin was used. 4. The retentive strength of the resin veneer was greatly affected by the angle of stress at the incisal resin. The retentive strength increased as the angle between the longitudinal axis of the specimen and the direction of stress decreased.

  10. Bait and the susceptibility of American lobsters Homarus americanus to epizootic shell disease.

    PubMed

    Bethoney, N David; Stokesbury, Kevin D E; Stevens, Bradley G; Altabet, Mark A

    2011-05-24

    Shell disease (SD) has been observed in lobster populations for almost a hundred years, but recently, rates of an epizootic form of shell disease (ESD) have increased in the southern New England (USA) area. A large proportion of fish in the diet of American lobsters Homarus americanus has been linked to increased rates of SD. Therefore, the use of fish as lobster bait may be linked to increased ESD rates in lobsters. Lobsters from the western portion of Martha's Vineyard, MA (41 degrees N, 71 degrees W), were randomly divided into 3 groups of 16 and exposed to dietary treatments (100% herring; 48% crab, 48% blue mussel and 4% plant matter; or 50% herring, 24% crab, 24% mussel, 2% plant matter) to determine if lobster tissue delta15N levels reflected diet. The results of the feeding experiment confirmed that differences in diet are observed in the delta15N levels of lobster muscle tissue. The delta15N levels of tissue samples from 175 wild lobsters with varying degrees of ESD were unrelated to ESD severity but did indicate lobsters were eating large amounts of fish (bait). This result does not support the speculation that fish used as bait is contributing to ESD outbreaks in portions of the southern New England area.

  11. Retrospective study: The diagnostic accuracy of conventional forceps biopsy of gastric epithelial compared to endoscopic submucosal dissection (STROBE compliant).

    PubMed

    Lu, Chao; Lv, Xueyou; Lin, Yiming; Li, Dejian; Chen, Lihua; Ji, Feng; Li, Youming; Yu, Chaohui

    2016-07-01

    Conventional forceps biopsy (CFB) is the most popular way to screen for gastric epithelial neoplasia (GEN) and adenocarcinoma of gastric epithelium. The aim of this study was to compare the diagnostic accuracy between conventional forceps biopsy and endoscopic submucosal dissection (ESD).Four hundred forty-four patients who finally undertook ESD in our hospital were enrolled from Jan 1, 2009 to Sep 1, 2015. We retrospectively assessed the characteristics of pathological results of CFB and ESD.The concordance rate between CFB and ESD specimens was 68.92% (306/444). Men showed a lower concordance rate (63.61% vs 79.33%; P = 0.001) and concordance patients were younger (P = 0.048). In multivariate analysis, men significantly had a lower concordance rate (coefficient -0.730, P = 0.002) and a higher rate of pathological upgrade (coefficient -0.648, P = 0.015). Locations of CFB did not influence the concordance rate statistically.The concordance rate was relatively high in our hospital. According to our analysis, old men plus gastric fundus or antrum of CFB were strongly suggested to perform ESD if precancerous lesions were found. And young women with low-grade intraepithelial neoplasia could select regular follow-up.

  12. Role of initial coherence on entanglement dynamics of two qubit X states

    NASA Astrophysics Data System (ADS)

    V, Namitha C.; Satyanarayana, S. V. M.

    2018-02-01

    Bipartite entanglement is a necessary resource in most processes in quantum information science. Decoherence resulting from the interaction of the bipartite system with environment not only degrades the entanglement, but can result in abrupt disentanglement, known as entanglement sudden death (ESD). In some cases, a subsequent revival of entanglement is also possible. ESD is an undesirable feature for the state to be used as a resource in applications. In order to delay or avoid ESD, it is necessary to understand its origin. In this work we investigate the role of initial coherence on entanglement dynamics of a spatially separated two qubit system in a common vacuum reservoir with dipolar interaction. We construct two classes of X states, namely, states with one photon coherence (X 1) and states with two photon coherence (X 2). Considering them as initial states, we study entanglement dynamics under Markov approximation. We find for states in X 1, ESD time, revival time and time over which the state remains disentangled increase with increase in coherence. On the other hand for states in X 2, with increase in coherence ESD time increases, revival time remains same and time of disentanglement decreases. Thus, states with two photon coherence are better resources for applications since their entanglement is robust against decoherence compared to states with one photon coherence.

  13. Risk factors of delayed ulcer healing after gastric endoscopic submucosal dissection.

    PubMed

    Lim, Joo Hyun; Kim, Sang Gyun; Choi, Jeongmin; Im, Jong Pil; Kim, Joo Sung; Jung, Hyun Chae

    2015-12-01

    Although post-endoscopic submucosal dissection (ESD) iatrogenic ulcer is known to heal faster than peptic ulcer, some iatrogenic ulcers show delayed healing. The aim of this study was to clarify risk factors of delayed ulcer healing after gastric ESD. We retrospectively reviewed medical records of all patients who had ESD for gastric neoplasms (866 adenomas and 814 early gastric cancers) between January 2005 and February 2011. Of 1680 subjects, 95 had delayed ulcer healing in 3-month follow-up. Multivariate analysis showed that diabetes (OR 1.743; 95% CI 1.017-2.989, p = 0.043), coagulation abnormality (OR 3.195; 95% CI 1.535-6.650, p = 0.002), specimen size greater than 4 cm (OR 2.999; 95% CI 1.603-5.611, p = 0.001), and electrocoagulation (OR 7.149; 95% CI 1.738-29.411, p = 0.006) were revealed to be independent risk factors of delayed ulcer healing. Meanwhile, persistent Helicobacter pylori infection was not related to the delayed ulcer healing. Large iatrogenic ulcer by ESD with massive hemostasis, especially in patients with diabetes mellitus or coagulation abnormalities, tends to take more than 3 months to heal. For such cases, initial dosage increment of PPI or addition of other anti-ulcer agents after ESD may be beneficial.

  14. Exploration Systems Development (ESD) Approach to Enterprise Risk Management

    NASA Technical Reports Server (NTRS)

    Bauder, Stephen P.

    2014-01-01

    The National Aeronautics and Space Administration (NASA) Exploration Systems Development (ESD) Division has implemented an innovative approach to Enterprise Risk Management under a unique governance structure and streamlined integration model. ESD's mission is to design and build the capability to extend human existence to deep space. The Enterprise consists of three Programs: Space Launch System (SLS), Orion, and Ground Systems Development and Operations (GSDO). The SLS is a rocket and launch system that will be capable of powering humans, habitats, and support systems to deep space. Orion will be the first spacecraft in history capable of taking humans to multiple destinations within deep space. GSDO is modernizing Kennedy's spaceport to launch spacecraft built and designed by both NASA and private industry. ESD's approach to Enterprise Risk Management is commensurate with affordability and a streamlined management philosophy. ESD Enterprise Risk Management leverages off of the primary mechanisms for integration within the Enterprise. The Enterprise integration approach emphasizes delegation of authority to manage and execute the majority of cross-program activities and products to the individual Programs, while maintaining the overall responsibility for all cross-program activities at the Division. The intent of the ESD Enterprise Risk Management approach is to improve risk communication, to avoid replication and/or contradictory strategies, and to minimize overhead process burden. This is accomplished by the facilitation and integration of risk information within ESD. The ESD Division risks, Orion risks, SLS risks, and GSDO risks are owned and managed by the applicable Program. When the Programs have shared risks with multiple consequences, they are jointly owned and managed. When a risk is associated with the integrated system that involves more than one Program in condition, consequence, or mitigation plan, it is considered an Exploration Systems Integration (ESI) Risk. An ESI risk may require visibility and risk handling by multiple organizations. The Integrated Risk Working Group (IRWG) is a small team of Risk experts that are responsible for collaborating and communicating best practices. In addition, the forum facilitates proper integration of risks across the Enterprise. The IRWG uses a Continuous Risk Management approach for facilitating the identification, analysis, planning, tracking, and controlling of ESI Risks. The ESD Division, Programs, and Integrated Task Teams identify ESI Risks. The IRWG maintains a set of metrics for understanding Enterprise Risk process and the overall Risk Posture. The team is also actively involved in the modeling of risk for Enterprise Performance Management. With the Enterprise being constrained in Schedule and Budget, and with significant technical complexity, the appropriate use of Risk Management techniques is crucial to the success of the Enterprise. The IRWG achieves this through the modified approach, providing a forum for collaboration on risks that cross boundaries between the separate entities.

  15. Accommodation and age-dependent eye model based on in vivo measurements.

    PubMed

    Zapata-Díaz, Juan F; Radhakrishnan, Hema; Charman, W Neil; López-Gil, Norberto

    2018-03-21

    To develop a flexible model of the average eye that incorporates changes with age and accommodation in all optical parameters, including entrance pupil diameter, under photopic, natural, environmental conditions. We collated retrospective in vivo measurements of all optical parameters, including entrance pupil diameter. Ray-tracing was used to calculate the wavefront aberrations of the eye model as a function of age, stimulus vergence and pupil diameter. These aberrations were used to calculate objective refraction using paraxial curvature matching. This was also done for several stimulus positions to calculate the accommodation response/stimulus curve. The model predicts a hyperopic change in distance refraction as the eye ages (+0.22D every 10 years) between 20 and 65 years. The slope of the accommodation response/stimulus curve was 0.72 for a 25 years-old subject, with little change between 20 and 45 years. A trend to a more negative value of primary spherical aberration as the eye accommodates is predicted for all ages (20-50 years). When accommodation is relaxed, a slight increase in primary spherical aberration (0.008μm every 10 years) between 20 and 65 years is predicted, for an age-dependent entrance pupil diameter ranging between 3.58mm (20 years) and 3.05mm (65 years). Results match reasonably well with studies performed in real eyes, except that spherical aberration is systematically slightly negative as compared with the practical data. The proposed eye model is able to predict changes in objective refraction and accommodation response. It has the potential to be a useful design and testing tool for devices (e.g. intraocular lenses or contact lenses) designed to correct the eye's optical errors. Copyright © 2018 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  16. Thermal models applicable for visual and infrared studies of orbital debris

    NASA Technical Reports Server (NTRS)

    Lebofsky, Larry A.; Vilas, Faith

    1990-01-01

    Over the past decade, thermal models have been developed for the determination of asteroid diameters and albedos. As a first step to understanding the size/frequency distribution of the debris population in earth orbit, these thermal models have been modified to determine the sizes of orbiting debris. When possible, the model results have been compared to spherical satellites of known diameter.

  17. Preliminary results of antiscarring therapy in the prevention of postendoscopic esophageal mucosectomy strictures

    PubMed Central

    Wu, Yuhsin; Schomisch, Steve J.; Cipriano, Cassandra; Chak, Amitabh; Lash, Richard H.; Ponsky, Jeffrey L.

    2015-01-01

    Background Esophageal endoscopic submucosal dissection (ESD) is an effective minimally invasive therapy for early esophageal cancer and high-grade Barrett dysplasia. However, esophageal stricture formation after circumferential or large ESD has limited its wide adoption. Mitomycin C (MMC), halofuginone (Hal), and transforming growth factor β3 (TGF-β3) exhibits antiscarring effects that may prevent post-ESD stricture formation. Methods Using endoscopic mucosectomy (EEM) technique, an 8- to 10-cm-long circumferential esophageal mucosal segment was excised in a porcine model. The site was either untreated (control, n = 6) or received 40 evenly distributed injections of antiscarring agent immediately and at weeks 1 and 2. High and low doses were used: MMC 5 mg (n = 2), 0.5 mg (n = 2); Hal 5 mg (n = 2), 1.5 mg (n = 2), 0.5 mg (n = 2); TGF-β3 2 μg (n = 2), 0.5 μg (n = 2). The degree of stricture formation was determined by the percentage reduction of the esophageal lumen on weekly fluoroscopic examination. Animals were euthanized when strictures exceeded 80 % or the animals were unable to maintain weight. Results The control group had a luminal diameter reduction of 78.2 ± 10.9 % by 2 weeks and were euthanized by week 3. Compared at 2 weeks, the Hal group showed a decrease in mean stricture formation (68.4 % low dose, 57.7 % high dose), while both TGF-β3 dosage groups showed no significant change (65.3 % low dose, 76.2 % high dose). MMC was most effective in stricture prevention (53.6 % low dose, 35 % high dose). Of concern, the esophageal wall treated with high-dose MMC appeared to be necrotic and eventually led to perforation. In contrast, low dose MMC, TGF-β3 and Hal treated areas appeared re-epithelialized and healthy. Conclusions Preliminary data on MMC and Hal demonstrated promise in reducing esophageal stricture formation after EEM. More animal data are needed to perform adequate statistical analysis in order to determine overall efficacy of antiscarring therapy. PMID:24100858

  18. DEVELOPMENT OF ELECTRO-ACOUSTIC SOIL DECONTAMINATION (ESD) FOR IN-SITU APPLICATIONS

    EPA Science Inventory

    The technical feasibility of electro-acoustic soil decontamination process through lab experiments demonstrated the removal/-concentration of heavy metals such as cadmium and zinc. Results of the decane contaminated soils were, however, inconclusive. The ESD process is based on t...

  19. Efficacy of treatment with rebamipide for endoscopic submucosal dissection-induced ulcers.

    PubMed

    Takayama, Masaki; Matsui, Shigenaga; Kawasaki, Masanori; Asakuma, Yutaka; Sakurai, Toshiharu; Kashida, Hiroshi; Kudo, Masatoshi

    2013-09-14

    To prospectively compare the healing rates of endoscopic submucosal dissection (ESD)-induced ulcers treated with either a proton-pump inhibitor (PPI) or rebamipide. We examined 90 patients with early gastric cancer who had undergone ESD. All patients were administered an intravenous infusion of the PPI lansoprazole (20 mg) every 12 h for 2 d, followed by oral administration of lansoprazole (30 mg/d, 5 d). After 7-d treatment, the patients were randomly assigned to 2 groups and received either lansoprazole (30 mg/d orally, n = 45; PPI group) or rebamipide (300 mg orally, three times a day; n = 45; rebamipide group). At 4 and 8 wk after ESD, the ulcer outcomes in the 2 groups were compared. No significant differences were noted in patient age, underlying disease, tumor location, Helicobacter pylori infection rate, or ESD-induced ulcer size between the 2 groups. At both 4 and 8 wk, the healing rates of ESD-induced ulcers were similar in the PPI-treated and the rebamipide-treated patients (4 wk: PPI, 27.2%; rebamipide, 33.3%; P = 0.5341; 8 wk: PPI, 90.9%; rebamipide, 93.3%; P = 0.6710). At 8 wk, the rates of granulation lesions following ulcer healing were significantly higher in the PPI-treated group (13.6%) than in the rebamipide-treated group (0.0%; P = 0.0103). Ulcer-related symptoms were similar in the 2 treatment groups at 8 wk. The medication cost of 8-wk treatment with the PPI was 10945 yen vs 4889 yen for rebamipide. No ulcer bleeding or complications due to the drugs were observed in either treatment group. The healing rate of ESD-induced ulcers was similar with rebamipide or PPI treatment; however, rebamipide treatment is more cost-effective and prevents granulation lesions following ulcer healing.

  20. The expansion of endoscopic submucosal dissection in France: A prospective nationwide survey.

    PubMed

    Barret, Maximilien; Lepilliez, Vincent; Coumaros, Dimitri; Chaussade, Stanislas; Leblanc, Sarah; Ponchon, Thierry; Fumex, Fabien; Chabrun, Edouard; Bauret, Paul; Cellier, Christophe; Coron, Emmanuel; Bichard, Philippe; Bulois, Philippe; Charachon, Antoine; Rahmi, Gabriel; Bellon, Serge; Lerhun, Marc; Arpurt, Jean-Pierre; Koch, Stéphane; Napoleon, Bertrand; Vaillant, Eric; Esch, Anouk; Farhat, Said; Robin, Francoise; Kaddour, Nadira; Prat, Frédéric

    2017-02-01

    Early reports of endoscopic submucosal dissection (ESD) in Europe suggested high complication rates and disappointing outcomes compared to publications from Japan. Since 2008, we have been conducting a nationwide survey to monitor the outcomes and complications of ESD over time. All consecutive ESD cases from 14 centers in France were prospectively included in the database. Demographic, procedural, outcome and follow-up data were recorded. The results obtained over three years were compared to previously published data covering the 2008-2010 period. Between November 2010 and June 2013, 319 ESD cases performed in 314 patients (62% male, mean (±SD) age 65.4 ± 12) were analyzed and compared to 188 ESD cases in 188 patients (61% male, mean (±SD) age 64.6 ± 13) performed between January 2008 and October 2010. The mean (±SD) lesion size was 39 ± 12 mm in 2010-2013 vs 32.1 ± 21 for 2008-2010 ( p  = 0.004). En bloc resection improved from 77.1% to 91.7% ( p  < 0.0001) while R0 en bloc resection remained stable from 72.9% to 71.9% ( p  = 0.8) over time. Complication rate dropped from 29.2% between 2008 and 2010 to 14.1% between 2010 and 2013 ( p  < 0.0001), with bleeding decreasing from 11.2% to 4.7% ( p  = 0.01) and perforations from 18.1% to 8.1% ( p  = 0.002) over time. No procedure-related mortality was recorded. In this multicenter study, ESD achieved high rates of en bloc resection with a significant trend toward better outcomes over time. Improvements in lesion delineation and characterization are still needed to increase R0 resection rates.

  1. A novel fully synthetic and self-assembled peptide solution for endoscopic submucosal dissection-induced ulcer in the stomach.

    PubMed

    Uraoka, Toshio; Ochiai, Yasutoshi; Fujimoto, Ai; Goto, Osamu; Kawahara, Yoshiro; Kobayashi, Naoya; Kanai, Takanori; Matsuda, Sachiko; Kitagawa, Yuko; Yahagi, Naohisa

    2016-06-01

    Endoscopic submucosal dissection (ESD) can remove early stage GI tumors of various sizes en bloc; however, success requires reducing the relatively high postprocedure bleeding rate. The aim of this study was to assess the safety and efficacy of a novel, fully synthetic, and self-assembled peptide solution that functions as an extracellular matrix scaffold material to facilitate reconstruction of normal tissues in ESD-induced ulcers. Consecutive patients who underwent gastric ESD were prospectively enrolled. Immediately after the resection, the solution was applied to the site with a catheter. Gastric ulcers were evaluated by endoscopy and classified as active, healing, or scarring stages at weeks 1, 4, and 8 after ESD. Forty-seven patients with 53 lesions, including 14 (29.8%) previously on antithrombotic therapy and 2 (4.3%) requiring heparin bridge therapy, were analyzed; 2 patients were excluded, 1 with perforations and 1 with persistent coagulopathy. The mean size of the en bloc resected specimens was 36.5 ± 11.3 mm. The rate of post-ESD bleeding was 2.0% (1/51; 95% CI, 0.03-10.3). Transitional rate to the healing stage of ESD-induced ulcers at week 1 was 96% (49/51). Subsequent endoscopies demonstrated the scarring stage in 19% (9/48) and 98% (41/42) at weeks 4 and 8, respectively. No adverse effects related to this solution occurred. The use of this novel peptide solution may potentially aid in reducing the delayed bleeding rate by promoting mucosal regeneration and speed of ulcer healing after large endoscopic resections in the stomach. Further studies, particularly randomized controlled studies, are needed to fully evaluate its efficacy. ( 000011548.). Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  2. Scissor-type knife significantly improves self-completion rate of colorectal endoscopic submucosal dissection: Single-center prospective randomized trial.

    PubMed

    Yamashina, Takeshi; Takeuchi, Yoji; Nagai, Kengo; Matsuura, Noriko; Ito, Takashi; Fujii, Mototsugu; Hanaoka, Noboru; Higashino, Koji; Uedo, Noriya; Ishihara, Ryu; Iishi, Hiroyasu

    2017-05-01

    Colorectal endoscopic submucosal dissection (C-ESD) is recognized as a difficult procedure. Recently, scissors-type knives were launched to reduce the difficulty of C-ESD. The aim of this study was to evaluate the efficacy and safety of the combined use of a scissors-type knife and a needle-type knife with a water-jet function (WJ needle-knife) for C-ESD compared with using the WJ needle-knife alone. This was a prospective randomized controlled trial in a referral center. Eighty-five patients with superficial colorectal neoplasms were enrolled and randomly assigned to undergo C-ESD using a WJ needle-knife alone (Flush group) or a scissor-type knife-supported WJ needle-knife (SB Jr group). Procedures were conducted by two supervised residents. Primary endpoint was self-completion rate by the residents. Self-completion rate was 67% in the SB Jr group, which was significantly higher than that in the Flush group (39%, P = 0.01). Even after exclusion of four patients in the SB Jr group in whom C-ESD was completed using the WJ needle-knife alone, the self-completion rate was significantly higher (63% vs 39%; P = 0.03). Median procedure time among the self-completion cases did not differ significantly between the two groups (59 vs 51 min; P = 0.14). No fatal adverse events were observed in either group. In this single-center phase II trial, scissor-type knife significantly improved residents' self-completion rate for C-ESD, with no increase in procedure time or adverse events. A multicenter trial would be warranted to confirm the validity of the present study. © 2016 Japan Gastroenterological Endoscopy Society.

  3. En bloc endoscopic submucosal dissection of a 14-cm laterally spreading adenoma of the rectum with involvement to the anal canal: expanding the frontiers of endoscopic surgery (with video).

    PubMed

    Antillon, Mainor R; Bartalos, Christopher R; Miller, Marc L; Diaz-Arias, Alberto A; Ibdah, Jamal A; Marshall, John B

    2008-02-01

    Endoscopic submucosal dissection (ESD) was recently developed in Japan for en bloc removal of laterally spreading tumors (LSTs). Although initially used for gastric tumors, ESD has now been applied to lesions elsewhere in the gut. Recent reports from Japan included removal of colorectal lesions up to 10 cm. To show the feasibility of ESD to remove en bloc, very large LSTs of the rectum, even when there is involvement to the dentate line. Case report. The procedure was performed at an American GI unit. The patient was admitted to the hospital after the procedure for observation. A 53-year-old patient, with a 14-cm tubulovillous adenoma of the rectum, which, at its maximal extent, involved two thirds of the circumference of the rectum. The tumor extended distally to the dentate line. En bloc submucosal dissection with a conventional needle-knife to remove the neoplasm. Completeness of en bloc removal of the tumor and subsequent follow-up endoscopy that showed no residual neoplasm. The tumor was able to be removed en bloc by ESD. The distal margin included squamous mucosa. At a 2.5-week endoscopic follow-up, a 3-mm focus of residual polyp was seen and removed. At the time of the last follow-up, there was complete healing of the wound and no residual neoplasm. Single case. This case demonstrated the feasibility of using ESD to remove large laterally spreading rectal tumors, including when there was involvement to the dentate line (and the dissection line must include squamous mucosa of the anal canal). ESD is a promising alternative to conventional surgical techniques; however, additional published experience is needed.

  4. [The Efficiency and Complications of ESD and ESTD in the Treatment of Large Esophageal Mucosal Lesions].

    PubMed

    Wang, Jin; Qin, Jin-yu; Guo, Tian-jiao; Gan, Tao; Wang, Yi-ping; Wu, Jun-chao

    2015-11-01

    To study the efficiency and complications of endoscopic submucosal dissection (ESD) and endoscopic submucosal tunnel dissection (ESTD) in the treatment of large esophageal mucosal lesions. The clinical data were collected from the patients who received ESD or ESTD for the treatment of early esophageal lesions in our hospital during January 1, 2014 to July 15, 2015, including the en bloc resection rate, curative resection rate, postoperative complication rate, the risk factors of complications were explored by univariate and multivariate analysis. A total of 50 patients were involved in the study, ESD or ESTD were performed successfully in 53 times, including 6 cases of ESD,47 cases of ESTD, The average age was (61.9 +/- 6.8) yr., the average operating time was (83.57 +/- 32.33) min, the average dissected lesion was (14.82 +/- 3.18) cm2, En bloc resection rate was 94.34%, the curative rate was 84.90%. There were 1 case of bleeding, 1 case of perforation, 45 (84.90%) cases of fever, 13 cases (24.53%) of esophageal stricture. The severity of stricture was associated with the operation time Codds ratio (OR) = 1.040, 95% confidence interal (CI): 1.007-1.075) and esophageal circumference (OR=9.972, 95% CI: 1.221-81.416). The residual resection margin appeared in 8 patients, and the lesion area (OR=1.145, 95% CI: 1.013-1.294) was the only risk factor. ESD and ESTD are safe and effective in the treatment of early esophageal lesions, but seems have relatively high incidence of esopgageal stricture and residual resection margin in the treatment of large esophageal lesions.

  5. Optimal duration of fasting period after endoscopic submucosal dissection for gastric epithelial neoplasia: A prospective evaluation.

    PubMed

    Oh, Kwang Hoon; Lee, Sang Jin; Park, Jong Kyu

    2017-08-01

    There are currently no standardized guidelines for adequately determining the fasting period following gastric endoscopic submucosal dissection (ESD). The aim of this study was to determine the appropriate fasting period. The enrolled patients were randomized into a short and a long-fasting group. In the short-fasting group, patients had fasted until the day after the ESD. In the long-fasting group, patients had fasted until 2 days after the ESD. A second-look endoscopy was performed immediately prior to starting to eat meals. The primary end-point was the measurement of discomfort-related ESD after starting meals such as epigastric pain, heartburn, regurgitation, nausea and vomiting. Secondary end-points included the bleeding rate after starting meals, hospital stay, patient satisfaction and hemostasis upon second-look endoscopy. We analyzed data from 101 of 110 randomized patients. Both groups demonstrated similar baseline characteristics. There were no significant differences in reports of epigastric pain, heartburn, regurgitation, nausea and vomiting after starting meals. Both groups demonstrated similar hemostasis rates upon second-look endoscopy (26% vs 31.4%, P = 0.551) and bleeding rate (4% vs 0%, P = 0.149). The duration of hospital stay was significantly shorter in the short-fasting group (4.3 days vs 5.1 days, P < 0.001), and patient satisfaction was greater (P = 0.003) than in the long-fasting group. A short fasting protocol does not cause discomfort related to ESD or influence post-ESD bleeding. Moreover, the short fasting protocol results in shorter hospital stays and greater patient satisfaction. © 2017 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  6. Features of electrocoagulation syndrome after endoscopic submucosal dissection for colorectal neoplasm.

    PubMed

    Yamashina, Takeshi; Takeuchi, Yoji; Uedo, Noriya; Hamada, Kenta; Aoi, Kenji; Yamasaki, Yasushi; Matsuura, Noriko; Kanesaka, Takashi; Akasaka, Tomofumi; Yamamoto, Sachiko; Hanaoka, Noboru; Higashino, Koji; Ishihara, Ryu; Iishi, Hiroyasu

    2016-03-01

    Endoscopic submucosal dissection (ESD) is a promising treatment for large gastrointestinal superficial neoplasms, although it is technically difficult, and perforation and delayed bleeding are well-known adverse events. However, there have been no large studies about electrocoagulation syndrome after colorectal ESD. The aim of this study was to evaluate the incidence and clinical significant risk factors of post-ESD coagulation syndrome (PECS). This was a retrospective cohort study conducted in a referral cancer center. A total of 336 patients with colorectal neoplasms (143 adenomas or serrated lesions and 193 carcinomas) underwent ESD from January 2011 to June 2013. Incidence, outcome, and factors associated with occurrence of PECS were investigated. Occurred in 32 patients (9.5%). The median time until PECS was 15.5 h, and the median period of PECS was 32.5 h. Fever (≥37.6 °C) after ESD was found in 41% of the PECS group and 9% of the non-PECS group (P < 0.001). All PECS cases were managed conservatively. On multivariate analysis, female patients (odds ratio [OR] = 3.2, P = 0.002), lesion location at ascending colon and cecum (OR = 3.5, P = 0.001), and resected specimen ≥40 mm (OR = 2.1, P = 0.05) were independent risk factors for PECS. Occurred in 32 patients (9.5%) with colorectal ESD; however, all cases had a good outcome with conservative management. Female sex, tumor location at the ascending colon and cecum, and resected specimen ≥40 mm were independently significant risk factors for PECS. © 2015 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  7. Developing Partnerships with the Community for Coastal ESD

    ERIC Educational Resources Information Center

    Kawabe, Midori; Kohno, Hiroshi; Ikeda, Reiko; Ishimaru, Takashi; Baba, Osamu; Horimoto, Naho; Kanda, Jota; Matsuyam, Masaji; Moteki, Masato; Oshima, Yayoi; Sasaki, Tsuyoshi; Yap, Minlee

    2013-01-01

    Purpose: The purpose of this paper is to draw lessons for developing community-university partnerships from experiences in promoting coastal education for sustainable development (ESD). Design/methodology/approach: Qualitative data collected from two coastal community outreach projects were analyzed. Findings: The outreach projects improved the…

  8. Incorporating hydrologic data and ecohydrologic relationships in ecological site descriptions

    USDA-ARS?s Scientific Manuscript database

    The purpose of this paper is to recommend a framework and methodology for inclusion of key ecohydrologic feedbacks and relationships in Ecological Site Descriptions (ESDs) and thereby enhance the utility of ESDs for assessing rangelands and guiding resilience-based management strategies. Resilience...

  9. Measurement of Entrance Surface Dose on an Anthropomorphic Thorax Phantom Using a Miniature Fiber-Optic Dosimeter

    PubMed Central

    Yoo, Wook Jae; Shin, Sang Hun; Jeon, Dayeong; Hong, Seunghan; Sim, Hyeok In; Kim, Seon Geun; Jang, Kyoung Won; Cho, Seunghyun; Youn, Won Sik; Lee, Bongsoo

    2014-01-01

    A miniature fiber-optic dosimeter (FOD) system was fabricated using a plastic scintillating fiber, a plastic optical fiber, and a multi-pixel photon counter to measure real-time entrance surface dose (ESD) during radiation diagnosis. Under varying exposure parameters of a digital radiography (DR) system, we measured the scintillating light related to the ESD using the sensing probe of the FOD, which was placed at the center of the beam field on an anthropomorphic thorax phantom. Also, we obtained DR images using a flat panel detector of the DR system to evaluate the effects of the dosimeter on image artifacts during posteroanterior (PA) chest radiography. From the experimental results, the scintillation output signals of the FOD were similar to the ESDs including backscatter simultaneously obtained using a semiconductor dosimeter. We demonstrated that the proposed miniature FOD can be used to measure real-time ESDs with minimization of DR image artifacts in the X-ray energy range of diagnostic radiology. PMID:24694678

  10. Measurement of entrance surface dose on an anthropomorphic thorax phantom using a miniature fiber-optic dosimeter.

    PubMed

    Yoo, Wook Jae; Shin, Sang Hun; Jeon, Dayeong; Hong, Seunghan; Sim, Hyeok In; Kim, Seon Geun; Jang, Kyoung Won; Cho, Seunghyun; Youn, Won Sik; Lee, Bongsoo

    2014-04-01

    A miniature fiber-optic dosimeter (FOD) system was fabricated using a plastic scintillating fiber, a plastic optical fiber, and a multi-pixel photon counter to measure real-time entrance surface dose (ESD) during radiation diagnosis. Under varying exposure parameters of a digital radiography (DR) system, we measured the scintillating light related to the ESD using the sensing probe of the FOD, which was placed at the center of the beam field on an anthropomorphic thorax phantom. Also, we obtained DR images using a flat panel detector of the DR system to evaluate the effects of the dosimeter on image artifacts during posteroanterior (PA) chest radiography. From the experimental results, the scintillation output signals of the FOD were similar to the ESDs including backscatter simultaneously obtained using a semiconductor dosimeter. We demonstrated that the proposed miniature FOD can be used to measure real-time ESDs with minimization of DR image artifacts in the X-ray energy range of diagnostic radiology.

  11. Laparoscopic-endoscopic cooperative surgery is a safe and effective treatment for superficial nonampullary duodenal tumors.

    PubMed

    Kyuno, Daisuke; Ohno, Keisuke; Katsuki, Shinichi; Fujita, Tomoki; Konno, Ai; Murakami, Takeshi; Waga, Eriko; Takanashi, Kunihiro; Kitaoka, Keisuke; Komatsu, Yuya; Sasaki, Kazuaki; Hirata, Koichi

    2015-11-01

    The use of endoscopic submucosal dissection (ESD) for duodenal neoplasms has increased in recent years, but delayed perforation and bleeding are also known to frequently occur. We present two cases in which duodenal adenoma was successfully treated with laparoscopic-endoscopic cooperative surgery. ESD was combined with laparoscopic seromuscular sutures. The lesions in both cases were located in the second portion of the duodenum. The patients requested resection of the lesion, and we performed laparoscopic-endoscopic cooperative surgery. After the laparoscopic surgeon mobilized the duodenum, the endoscopic surgeon performed ESD for the duodenal tumor without perforation. The laparoscopic surgeon sutured the duodenal wall in the seromuscular layer to strengthen the ulcer bed after ESD. Histopathological studies confirmed that the surgical margins were tumor-free in both cases. The patients were discharged with no complications. This unique laparoscopic-endoscopic cooperative procedure is a safe and effective method for resecting superficial nonampullary duodenal tumors. © 2015 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  12. Assessment of Reproducibility of Laser Electrospray Mass Spectrometry using Electrospray Deposition of Analyte

    NASA Astrophysics Data System (ADS)

    Sistani, Habiballah; Karki, Santosh; Archer, Jieutonne J.; Shi, Fengjian; Levis, Robert J.

    2017-05-01

    A nonresonant, femtosecond (fs) laser is employed to desorb samples of Victoria blue deposited on stainless steel or indium tin oxide (ITO) slides using either electrospray deposition (ESD) or dried droplet deposition. The use of ESD resulted in uniform films of Victoria blue whereas the dried droplet method resulted in the formation of a ring pattern of the dye. Laser electrospray mass spectrometry (LEMS) measurements of the ESD-prepared films on either substrate were similar and revealed lower average relative standard deviations for measurements within-film (20.9%) and between-films (8.7%) in comparison to dried droplet (75.5% and 40.2%, respectively). The mass spectral response for ESD samples on both substrates was linear (R2 > 0.99), enabling quantitative measurements over the selected range of 7.0 × 10-11 to 2.8 × 10-9 mol, as opposed to the dried droplet samples where quantitation was not possible (R2 = 0.56). The limit of detection was measured to be 210 fmol.

  13. ESD robustness improving for the low-voltage triggering silicon-controlled rectifier by adding NWell at cathode

    NASA Astrophysics Data System (ADS)

    Jin, Xiangliang; Zheng, Yifei; Wang, Yang; Guan, Jian; Hao, Shanwan; Li, Kan; Luo, Jun

    2018-01-01

    The low-voltage triggering silicon-controlled rectifier (LVTSCR) device is widely used in on-chip electrostatic discharge (ESD) protection owing to its low trigger voltage and strong current-tolerating capability per area. In this paper, an improved LVTSCR by adding a narrow NWell (NW2) under the source region of NMOS is discussed, which is realized in a 0.5-μm CMOS process. A 2-dimension (2D) device simulation platform and a transmission line pulse (TLP) testing system are used to predict and characterize the proposed ESD protection devices. According to the measurement results, compared with the preliminary LVTSCR, the improved LVTSCR elevates the second breakdown current (It2) from 2.39 A to 5.54 A and increases the holding voltage (Vh) from 3.04 V to 4.09 V without expanding device area or sacrificing any ESD performances. Furthermore, the influence of the size of the narrow NWell under the source region of NMOS on holding voltage is also discussed.

  14. Large early gastric cancers treated by endoscopic submucosal dissection with an insulation-tipped diathermic knife.

    PubMed

    Chang, Chun-Chao; Tiong, Cheng; Fang, Chia-Lang; Pan, Shiann; Liu, Jean-Dean; Lou, Horng-Yuan; Hsieh, Ching-Ruey; Chen, Sheng-Hsuan

    2007-03-01

    It is difficult to remove a large early gastric cancer (> or = 3 cm) in one-piece resection using conventional endoscopic mucosal resection. We tried to use an insulation-tipped (IT) diathermic knife to dissect these lesions. IT-endoscopic submucosal dissection (ESD) was performed in four aging patients with gastric malignancy. All lesions could be removed in one-piece resection by IT-ESD, although three of them exhibited remarkable fibrosis and ulceration. Three cases experienced curative treatment with IT-ESD after the pathologic evaluation, but it was not curative in one case because the pathology showed angiolymphatic invasion. This patient refused additional surgery in consideration of existing major systemic diseases. At 3 months to 1 year of follow-up, endoscopy showed no evidence of residual cancer. IT-ESD is effective in the treatment of large early gastric cancer and is an alternative treatment for early gastric cancer patients who are at risk for major operation.

  15. Superfund record of decision amendment (EPA region 9): Litchfield Airport Area, AKA: Phoenix-Goodyear Airport, Goodyear/Avondale, AZ, December 22, 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1997-03-01

    This document provides a brief background of the site, a summary of the remedy selected in the 1989 ROD (PB90-203498) and how that remedy was modified by the 1991 (PB95-463105) and 1993 (PB95-963104) ESDs, a description of how this ESD affects the remedy originally selected by EPA in the 1989 ROD, and an explanation of why EPA is making these changes to the ROD. EPA is issuing this third ESD to the 1989 ROD in order to take into account information received by EPA after EPA`s issuance of the 1991 and 1993 ESDs. The southern portion of the site consistsmore » of the Loral Defense Systems-Arizona (Loral) property and the Phoenix-Goodyear Airport property and any groundwater contamination emanating from these areas. The northern portion of the site consists of the Unidynamics property and any groundwater contamination emanating from these areas.« less

  16. Design of laser afocal zoom expander system

    NASA Astrophysics Data System (ADS)

    Jiang, Lian; Zeng, Chun-Mei; Hu, Tian-Tian

    2018-01-01

    Laser afocal zoom expander system due to the beam diameter variable, can be used in the light sheet illumination microscope to observe the samples of different sizes. Based on the principle of afocal zoom system, the laser collimation and beam expander system with a total length of less than 110mm, 6 pieces of spherical lens and a beam expander ratio of 10 is designed by using Zemax software. The system is focused on laser with a wavelength of 532nm, divergence angle of less than 4mrad and incident diameter of 4mm. With the combination of 6 spherical lens, the beam divergence angle is 0.4mrad at the maximum magnification ratio, and the RMS values at different rates are less than λ/4. This design is simple in structure and easy to process and adjust. It has certain practical value.

  17. Empirical Relationships Between Optical Properties and Equivalent Diameters of Fractal Soot Aggregates at 550 Nm Wavelength.

    NASA Technical Reports Server (NTRS)

    Pandey, Apoorva; Chakrabarty, Rajan K.; Liu, Li; Mishchenko, Michael I.

    2015-01-01

    Soot aggregates (SAs)-fractal clusters of small, spherical carbonaceous monomers-modulate the incoming visible solar radiation and contribute significantly to climate forcing. Experimentalists and climate modelers typically assume a spherical morphology for SAs when computing their optical properties, causing significant errors. Here, we calculate the optical properties of freshly-generated (fractal dimension Df = 1.8) and aged (Df = 2.6) SAs at 550 nm wavelength using the numericallyexact superposition T-Matrix method. These properties were expressed as functions of equivalent aerosol diameters as measured by contemporary aerosol instruments. This work improves upon previous efforts wherein SA optical properties were computed as a function of monomer number, rendering them unusable in practical applications. Future research will address the sensitivity of variation in refractive index, fractal prefactor, and monomer overlap of SAs on the reported empirical relationships.

  18. Synthesis and characterization of pHLIP® coated gold nanoparticles.

    PubMed

    Daniels, Jennifer L; Crawford, Troy M; Andreev, Oleg A; Reshetnyak, Yana K

    2017-07-01

    Novel approaches in synthesis of spherical and multispiked gold nanoparticles coated with polyethylene glycol (PEG) and pH Low Insertion Peptide (pHLIP ® ) were introduced. The presence of a tumor-targeting pHLIP ® peptide in the nanoparticle coating enhances the stability of particles in solution and promotes a pH-dependent cellular uptake. The spherical particles were prepared with sodium citrate as a gold reducing agent to form particles of 7.0±2.5 nm in mean metallic core diameter and ∼43 nm in mean hydrodynamic diameter. The particles that were injected into tumors in mice (21 µg of gold) were homogeneously distributed within a tumor mass with no staining of the muscle tissue adjacent to the tumor. Up to 30% of the injected gold dose remained within the tumor one hour post-injection. The multispiked gold nanoparticles with a mean metallic core diameter of 146.0±50.4 nm and a mean hydrodynamic size of ~161 nm were prepared using ascorbic acid as a reducing agent and disk-like bicelles as a template. Only the presence of a soft template, like bicelles, ensured the appearance of spiked nanoparticles with resonance in the near infrared region. The irradiation of spiked gold nanoparticles by an 805 nm laser led to the time- and concentration-dependent increase of temperature. Both pHLIP ® and PEG coated gold spherical and multispiked nanoparticles might find application in radiation and thermal therapies of tumors.

  19. Volume determination of irregularly-shaped quasi-spherical nanoparticles.

    PubMed

    Attota, Ravi Kiran; Liu, Eileen Cherry

    2016-11-01

    Nanoparticles (NPs) are widely used in diverse application areas, such as medicine, engineering, and cosmetics. The size (or volume) of NPs is one of the most important parameters for their successful application. It is relatively straightforward to determine the volume of regular NPs such as spheres and cubes from a one-dimensional or two-dimensional measurement. However, due to the three-dimensional nature of NPs, it is challenging to determine the proper physical size of many types of regularly and irregularly-shaped quasi-spherical NPs at high-throughput using a single tool. Here, we present a relatively simple method that determines a better volume estimate of NPs by combining measurements from their top-down projection areas and peak heights using two tools. The proposed method is significantly faster and more economical than the electron tomography method. We demonstrate the improved accuracy of the combined method over scanning electron microscopy (SEM) or atomic force microscopy (AFM) alone by using modeling, simulations, and measurements. This study also exposes the existence of inherent measurement biases for both SEM and AFM, which usually produce larger measured diameters with SEM than with AFM. However, in some cases SEM measured diameters appear to have less error compared to AFM measured diameters, especially for widely used IS-NPs such as of gold, and silver. The method provides a much needed, proper high-throughput volumetric measurement method useful for many applications. Graphical Abstract The combined method for volume determination of irregularly-shaped quasi-spherical nanoparticles.

  20. Infected Aneurysm after Endoscopic Submucosal Dissection.

    PubMed

    Gen, Shiko; Usui, Ryuichi; Sasaki, Takaya; Nobe, Kanako; Takahashi, Aya; Okudaira, Keisuke; Ikeda, Naofumi

    2016-01-01

    A 79-year-old man on hemodialysis was hospitalized for further investigation. Early gastric cancer was diagnosed by gastrointestinal endoscopy and endoscopic submucosal dissection (ESD) was performed. Fever and abdominal pain thereafter developed, and a severe inflammatory response was observed on a blood test. Contrast computed tomography (CT) showed ulcer-like projections and soft tissue surrounding the aorta, from the celiac to left renal artery. An infected aneurysm was diagnosed. Although infected aneurysms developing after laparoscopic cholecystectomy or biopsy of contiguous esophageal duplication cyst have been reported, those developing after ESD have not. When fever and abdominal pain develop after ESD, an infected aneurysm should be considered and contrast CT performed.

  1. Body-size spectra of biofilm-dwelling protozoa and their seasonal shift in coastal ecosystems.

    PubMed

    Zhao, Lu; Xu, Guangjian; Wang, Zheng; Xu, Henglong

    2016-10-01

    Community-based assessment of protozoa is usually performed at a taxon-dependent resolution. As an inherent 'taxon-free' trait, however, body-size spectrum has proved to be a highly informative indicator to summarize the functional structure of a community in both community research and monitoring programs in aquatic ecosystems. To demonstrate the relationships between the taxon-free resolution of protozoan communities and water conditions, the body-size spectra of biofilm-dwelling protozoa and their seasonal shift and environmental drivers were explored based on an annual dataset collected monthly from coastal waters of the Yellow Sea, northern China. Body sizes were calculated in equivalent spherical diameter (ESD). Among a total of 8 body-size ranks, S2 (19-27μm), S3 (28-36μm), S4 (37-50μm) and S5 (53-71μm) were the top four levels in frequency of occurrence, while rank S1 (13-17μm), S2 and S4 were the dominant levels in abundance. These dominants showed a clear seasonal succession: S2/S4 (spring)→S2/S4 (summer)→S4 (autumn)→S2 (winter) in frequency of occurrence; S1 (spring)→S4 (summer)→S2 (autumn)→S1 (winter) in abundance. Bootstrapped average analysis showed a clear seasonal shift in body-size spectra of the protozoa during a 1-year cycle, and the best-matching analysis demonstrated that the temporal variations in frequency of occurrence and abundance were significantly correlated with water temperature, pH, dissolved oxygen (DO), alone or in combination with chemical oxygen demand (COD) and nutrients. Thus, the body-size spectra of biofilm-dwelling protozoa were seasonally shaped and might be used as a time and cost efficient bioindicator of water quality in marine ecosystems. Copyright © 2016 Elsevier GmbH. All rights reserved.

  2. Four-zone varifocus mirrors with adaptive control of primary and higher-order spherical aberration

    PubMed Central

    Lukes, Sarah J.; Downey, Ryan D.; Kreitinger, Seth T.; Dickensheets, David L.

    2017-01-01

    Electrostatically actuated deformable mirrors with four concentric annular electrodes can exert independent control over defocus as well as primary, secondary, and tertiary spherical aberration. In this paper we use both numerical modeling and physical measurements to characterize recently developed deformable mirrors with respect to the amount of spherical aberration each can impart, and the dependence of that aberration control on the amount of defocus the mirror is providing. We find that a four-zone, 4 mm diameter mirror can generate surface shapes with arbitrary primary, secondary, and tertiary spherical aberration over ranges of ±0.4, ±0.2, and ±0.15 μm, respectively, referred to a non-normalized Zernike polynomial basis. We demonstrate the utility of this mirror for aberration-compensated focusing of a high NA optical system. PMID:27409212

  3. Application of ecological site information to transformative changes on Great Basin sagebrush rangelands

    USDA-ARS?s Scientific Manuscript database

    Ecological Site Description (ESD) concepts are broadly applicable and provide a necessary framework to inform and guide rangeland management decisions. In this paper, we demonstrate how understanding and quantification of key vegetation, hydrology, and soil relationships in the ESD context can info...

  4. National assessment and critiques of state-and-transition models: The baby with the bathwater

    USDA-ARS?s Scientific Manuscript database

    Ecological site descriptions (ESDs) have been characterized as the world’ s largest land management framework. They comprise a database and document collection used throughout the United States to provide management guidance in rangelands and, increasingly, in forests, wetlands, and croplands. ESDs ...

  5. Downscaling reanalysis data to high-resolution variables above a glacier surface (Cordillera Blanca, Peru)

    NASA Astrophysics Data System (ADS)

    Hofer, Marlis; Mölg, Thomas; Marzeion, Ben; Kaser, Georg

    2010-05-01

    Recently initiated observation networks in the Cordillera Blanca provide temporally high-resolution, yet short-term atmospheric data. The aim of this study is to extend the existing time series into the past. We present an empirical-statistical downscaling (ESD) model that links 6-hourly NCEP/NCAR reanalysis data to the local target variables, measured at the tropical glacier Artesonraju (Northern Cordillera Blanca). The approach is particular in the context of ESD for two reasons. First, the observational time series for model calibration are short (only about two years). Second, unlike most ESD studies in climate research, we focus on variables at a high temporal resolution (i.e., six-hourly values). Our target variables are two important drivers in the surface energy balance of tropical glaciers; air temperature and specific humidity. The selection of predictor fields from the reanalysis data is based on regression analyses and climatologic considerations. The ESD modelling procedure includes combined empirical orthogonal function and multiple regression analyses. Principal component screening is based on cross-validation using the Akaike Information Criterion as model selection criterion. Double cross-validation is applied for model evaluation. Potential autocorrelation in the time series is considered by defining the block length in the resampling procedure. Apart from the selection of predictor fields, the modelling procedure is automated and does not include subjective choices. We assess the ESD model sensitivity to the predictor choice by using both single- and mixed-field predictors of the variables air temperature (1000 hPa), specific humidity (1000 hPa), and zonal wind speed (500 hPa). The chosen downscaling domain ranges from 80 to 50 degrees west and from 0 to 20 degrees south. Statistical transfer functions are derived individually for different months and times of day (month/hour-models). The forecast skill of the month/hour-models largely depends on month and time of day, ranging from 0 to 0.8, but the mixed-field predictors generally perform better than the single-field predictors. At all time scales, the ESD model shows added value against two simple reference models; (i) the direct use of reanalysis grid point values, and (ii) mean diurnal and seasonal cycles over the calibration period. The ESD model forecast 1960 to 2008 clearly reflects interannual variability related to the El Niño/Southern Oscillation, but is sensitive to the chosen predictor type. So far, we have not assessed the performance of NCEP/NCAR reanalysis data against other reanalysis products. The developed ESD model is computationally cheap and applicable wherever measurements are available for model calibration.

  6. Empirical-statistical downscaling of reanalysis data to high-resolution air temperature and specific humidity above a glacier surface (Cordillera Blanca, Peru)

    NASA Astrophysics Data System (ADS)

    Hofer, Marlis; MöLg, Thomas; Marzeion, Ben; Kaser, Georg

    2010-06-01

    Recently initiated observation networks in the Cordillera Blanca (Peru) provide temporally high-resolution, yet short-term, atmospheric data. The aim of this study is to extend the existing time series into the past. We present an empirical-statistical downscaling (ESD) model that links 6-hourly National Centers for Environmental Prediction (NCEP)/National Center for Atmospheric Research (NCAR) reanalysis data to air temperature and specific humidity, measured at the tropical glacier Artesonraju (northern Cordillera Blanca). The ESD modeling procedure includes combined empirical orthogonal function and multiple regression analyses and a double cross-validation scheme for model evaluation. Apart from the selection of predictor fields, the modeling procedure is automated and does not include subjective choices. We assess the ESD model sensitivity to the predictor choice using both single-field and mixed-field predictors. Statistical transfer functions are derived individually for different months and times of day. The forecast skill largely depends on month and time of day, ranging from 0 to 0.8. The mixed-field predictors perform better than the single-field predictors. The ESD model shows added value, at all time scales, against simpler reference models (e.g., the direct use of reanalysis grid point values). The ESD model forecast 1960-2008 clearly reflects interannual variability related to the El Niño/Southern Oscillation but is sensitive to the chosen predictor type.

  7. Sex and the Catasetinae (Darwin's favourite orchids).

    PubMed

    Pérez-Escobar, Oscar Alejandro; Gottschling, Marc; Whitten, W Mark; Salazar, Gerardo; Gerlach, Günter

    2016-04-01

    Two sexual systems are predominant in Catasetinae (Orchidaceae), namely protandry (which has evolved in other orchid lineages as well) and environmental sex determination (ESD) being a unique trait among Orchidaceae. Yet, the lack of a robust phylogenetic framework for Catasetinae has hampered deeper insights in origin and evolution of sexual systems. To investigate the origins of protandry and ESD in Catasetinae, we sequenced nuclear and chloroplast loci from 77 species, providing the most extensive data matrix of Catasetinae available so far with all major lineages represented. We used Maximum Parsimony, Maximum Likelihood and Bayesian methods to infer phylogenetic relationships and evolution of sexual systems. Irrespectively of the methods used, Catasetinae were monophyletic in molecular phylogenies, with all established generic lineages and their relationships resolved and highly supported. According to comparative reconstruction approaches, the last common ancestor of Catasetinae was inferred as having bisexual flowers (i.e., lacking protandry and ESD as well), and protandry originated once in core Catasetinae (comprising Catasetum, Clowesia, Cycnoches, Dressleria and Mormodes). In addition, three independent gains of ESD are reliably inferred, linked to corresponding loss of protandry within core Catasetinae. Thus, prior gain of protandry appears as the necessary prerequisite for gain of ESD in orchids. Our results contribute to a comprehensive evolutionary scenario for sexual systems in Catasetinae and more generally in orchids as well. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. pH-dependent structural change of the extracellular sensor domain of the DraK histidine kinase from Streptomyces coelicolor.

    PubMed

    Yeo, Kwon Joo; Kim, Eun Hye; Hwang, Eunha; Han, Young-Hyun; Eo, Yumi; Kim, Hyun Jung; Kwon, Ohsuk; Hong, Young-Soo; Cheong, Chaejoon; Cheong, Hae-Kap

    2013-02-15

    Recently, the DraR/DraK (Sco3063/Sco3062) two-component system (TCS) of Streptomycescoelicolor has been reported to be involved in the differential regulation of antibiotic biosynthesis. However, it has not been shown that under which conditions and how the DraR/DraK TCS is activated to initiate the signal transduction process. Therefore, to understand the sensing mechanism, structural study of the sensory domain of DraK is highly required. Here, we report the biochemical and biophysical properties of the extracellular sensory domain (ESD) of DraK. We observed a reversible pH-dependent conformational change of the ESD in a pH range of 2.5-10. Size-exclusion chromatography and AUC (analytical ultracentrifugation) data indicated that the ESD is predominantly monomeric in solution and exists in equilibrium between monomer and dimer states in acidic condition. Using NMR (nuclear magnetic resonance) and CD (circular dichroism) spectroscopy, our findings suggest that the structure of the ESD at low pH is more structured than that at high pH. In particular, the glutamate at position 83 is an important residue for the pH-dependent conformational change. These results suggest that this pH-dependent conformational change of ESD may be involved in signal transduction process of DraR/DraK TCS. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Endoscopic Submucosal Dissection Using a Novel Versatile Knife: An Animal Feasibility Study (with Video)

    PubMed Central

    Kwon, Chang-Il; Kim, Gwangil; Kim, Won Hee; Ko, Kwang Hyun; Hong, Sung Pyo; Jeong, Seok; Lee, Don Haeng

    2014-01-01

    Background/Aims In order to reduce the procedure time and the number of accessory changes during endoscopic submucosal dissection (ESD), we developed a novel versatile knife, which has the combined advantages of several conventional knives. The aim of this study was to compare the efficacy, safety, and histological quality of ESD performed using this novel versatile knife and a combination of several conventional knives. Methods This was an in vivo animal study comparing two different modalities of ESD in mini-pigs. Completion time of each resection was documented, and the resected specimens were retrieved and evaluated for completeness. To assess the quality control of the procedures and adverse events, detailed histopathological examinations were performed. Results A total of 18 specimens were dissected by ESD safely and easily (nine specimens using the new versatile knife; nine specimens by mixing conventional knives). All resections were completed as en bloc resections. There was no significant difference in procedure time between the 2 modalities (456 seconds vs. 355 seconds, p=0.258) and cutting speed (1.983 mm2/sec vs. 1.57 mm2/sec, p=1.000). The rate of adverse events and histological quality did not statistically differ between the modalities. Conclusions ESD with a versatile knife appeared to be an easy, safe, and technically efficient method. PMID:25505721

  10. Environmental Sciences Division annual progress report for period ending September 30, 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-04-01

    This progress report summarizes the research and development activities conducted in the Environmental Sciences Division of Oak Ridge National Laboratory during the period October 1, 1990, through September 30, 1991. The report is structured to provide descriptions of current activities and accomplishments in each of the division`s major organizational units. Following the sections describing the organizational units is a section devoted to lists of information necessary to convey the scope of the work in the division. The Environmental Sciences Division (ESD) at Oak Ridge National Laboratory (ORNL) conducts environmental research and analyses associated with both energy technology development and themore » interactions between people and the environment. The division engages in basic and applied research for a diverse list of sponsors. While the US Department of Energy (DOE) is the primary sponsor ESD staff also perform research for other federal agencies, state agencies, and private industry. The division works collaboratively with federal agencies, universities, and private organizations in achieving its research objectives and hosts a large number of visiting investigators from these organizations. Given the diverse interdisciplinary specialization of its staff, ESD provides technical expertise on complex environmental problems and renders technical leadership for major environmental issues of national and local concern. This progress report highlights many of ESD`s accomplishment in these and other areas in FY 1991.« less

  11. An innovative architectural design to enhance the electrochemical performance of La2NiO4+δ cathodes for solid oxide fuel cell applications

    NASA Astrophysics Data System (ADS)

    Sharma, Rakesh K.; Burriel, Mónica; Dessemond, Laurent; Martin, Vincent; Bassat, Jean-Marc; Djurado, Elisabeth

    2016-06-01

    An architectural design of the cathode microstructure based on combining electrostatic spray deposition (ESD) and screen-printing (SP) techniques has demonstrated to be an innovative strategy to enhance the electrochemical properties of La2NiO4+δ (LNO) as oxygen electrode on Ce0.9Gd0.1O2-δ (CGO) electrolyte for solid oxide fuel cells. For this purpose, the influence of the ESD process parameters on the microstructure has been systematically investigated. Electrochemical performances of four selected cathode microstructures are investigated: (i) 3-D coral nanocrystalline (average particle size ∼ 100 nm) LNO film grown by ESD; (ii) 3-D coral nanocrystalline film (average particle size ∼ 150 nm) grown by ESD with a continuous nanometric dense interface; (iii) porous screen-printed LNO film (average particle size ∼ 400 nm); and (iv) 3-D coral nanocrystalline film (average particle size ∼ 150 nm) with a continuous nanometric dense interface prepared by ESD topped by a LNO current collector prepared by SP. A significant reduction in the polarization resistance (Rpol) is obtained (0.08 Ω cm2 at 700 °C) for 3-D coral topped by the SP layer. Moreover LNO is found to be stable and compatible with CGO up to 800 °C for only 10 days duration in air, making it potentially suitable for SOFCs cathode application.

  12. Preparation of spherical particles by vibrating orifice technique

    NASA Astrophysics Data System (ADS)

    Shibata, Shuichi; Tomizawa, Atsushi; Yoshikawa, Hidemi; Yano, Tetsuji; Yamane, Masayuki

    2000-05-01

    Preparation of micrometer-sized spherical particles containing Rhodamine 6G (R6G) has been investigated for the spherical cavity micro-laser. Using phenyl triethoxy silane (PTES) as a starting material, R6G-doped monodisperse spherical particles were prepared by the vibrating orifice technique. Processing consists of two major processes: (1) Hydrolysis and polymerization of PTES and (2) Droplet formation from PTES oligomers by vibrating orifice technique. A cylindrical liquid jet passing through the orifice of 10 and 20 micrometers in diameter breaks up into equal- sized droplets by mechanical vibration. Alcohol solvent of these droplets was evaporated during flying with carrier gas and subsequently solidified in ammonium water trap. For making smooth surface and god shaped particles, control of molecular weight of PTES oligomer was essential. R6G-doped hybrid spherical particles of 4 to 10 micrometers size of cavity structure were successfully obtained. The spherical particles were pumped by a second harmonic pulse of Q- switched Nd:YAG laser and laser emission peaks were observed at wavelengths which correspond to the resonance modes.

  13. Axial jet mixing of ethanol in spherical containers during weightlessness

    NASA Technical Reports Server (NTRS)

    Audelott, J. C.

    1976-01-01

    An experimental program was conducted to examine the liquid flow patterns that result from the axial jet mixing of ethanol in 10-centimeter-diameter spherical containers in weightlessness. Complete liquid circulation flow patterns were easily established in containers that were less than half full of liquid, while for higher liquid fill conditions, vapor was drawn into the inlet of the simulated mixer unit. Increasing the liquid-jet or lowering the position at which the liquid jet entered the container caused increasing turbulence and bubble formation.

  14. Atomic oxygen effects on metals

    NASA Technical Reports Server (NTRS)

    Fromhold, Albert T.

    1987-01-01

    The effect of specimen geometry on the attack of metals by atomic oxygen is addressed. This is done by extending the coupled-currents approach in metal oxidation to spherical and cylindrical geometries. Kinetic laws are derived for the rates of oxidation of samples having these geometries. It is found that the burn-up time for spherical particles of a given diameter can be as much as a factor of 3 shorter than the time required to completely oxidize a planar sample of the same thickness.

  15. Spherical crystals of Pb 1 - xSn xTe grown in microgravity

    NASA Astrophysics Data System (ADS)

    Kinoshita, Kyoichi; Yamada, Tomoaki

    1996-07-01

    Pb 1- xSn xTe spherical crystals were unintentionally obtained along with a cylindrical Pb 1 - xSn xTe crystal grown during the {SL-J}/{FMPT} mission on board the space shuttle "Endeavor". About 25 spherical crystals ranged from 0.5 to 11 mm in diameter. Melt leaked from the melt reservoir into the spring that plays the role of pushing the melt toward a seed crystal and eliminating free surface areas of the melt. Because of the surface tension of the melt, spherical melt drops formed in the hollow of the spring, then solidified into spherical crystals during the cooling process. Some of the crystals had lower dislocation densities, in the order of 10 4 cm -2, two orders smaller than those of terrestrially grown crystals from a melt. The experiment showed a way of stably positioning a large volume of liquid in microgravity without touching the crucible wall and a way of reducing crystalline defects by such growth.

  16. The Development of ESD-Related Competencies in Supportive Institutional Frameworks

    ERIC Educational Resources Information Center

    de Haan, Gerhard

    2010-01-01

    Although Education for Sustainable Development (ESD) is a matter of global importance, the requirements and needs of people differ according to their regional circumstances. (Not only) in Germany--in keeping with the increasingly international focus of "output" evaluations--one dominant educational debate has centred on effective ways of…

  17. Incorporating hydrologic data and ecohydrologic relationships into ecological site descriptions

    Treesearch

    C. Jason Williams; Frederick B. Pierson; Kenneth E. Spaeth; Joel R. Brown; Osama Z. Al-Hamdan; Mark A. Weltz; Mark A. Nearing; Jeffrey E. Herrick; Jan Boll; Pete Robichaud; David C. Goodrich; Phillip Heilman; D. Phillip Guertin; Mariano Hernandez; Haiyan Wei; Stuart P. Hardegree; Eva K. Strand; Jonathan D. Bates; Loretta J. Metz; Mary H. Nichols

    2016-01-01

    The purpose of this paper is to recommend a framework and methodology for incorporating hydrologic data and ecohydrologic relationships in Ecological Site Descriptions (ESDs) and thereby enhance the utility of ESDs for assessing rangelands and guiding resilience-based management strategies. Resilience-based strategies assess and manage ecological state...

  18. Levels of Indicator Development for Education for Sustainable Development

    ERIC Educational Resources Information Center

    Rode, Horst; Michelsen, Gerd

    2008-01-01

    The article summarizes some considerations about the development of indicators for education for sustainable development (ESD). It reflects the present state of discussion, especially from a German perspective, and includes present developments in the area of quality criteria and standards for ESD. These discussion threads only denote the…

  19. Education for Sustainable Human Development: Towards a Definition

    ERIC Educational Resources Information Center

    Landorf, Hilary; Doscher, Stephanie; Rocco, Tonette

    2008-01-01

    Three years into the Decade of Education for Sustainable Development, there has been considerable discussion regarding education for sustainable development (ESD) at a policy level, yet very few countries and communities have moved to integrate ESD into their educational curriculum. In this article we argue that the conceptualization and…

  20. Education for Sustainable Development: Connecting the Dots for Sustainability

    ERIC Educational Resources Information Center

    Gokool-Ramdoo, Sushita; Rumjaun, Anwar Bhai

    2017-01-01

    Critical pedagogy, practitioner experience and a regulatory perspective are employed to scrutinize the notion of Education for Sustainable Development (ESD) as it occurs in the literature. They promote understanding of the challenges impeding the completion of unfinished ESD businesses. In response to practitioner-expressed needs, this paper…

  1. 40 CFR 35.4270 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... Explanation of Significant Differences (ESD) means the document issued by the agency leading a cleanup that describes to the public significant changes made to a Record of Decision after the ROD has been signed. The ESD must also summarize the information that led to the changes and affirm that the revised remedy...

  2. Digital Citizenship in the Afterschool Space: Implications for Education for Sustainable Development

    ERIC Educational Resources Information Center

    Howard, Patrick

    2015-01-01

    Education for sustainable development (ESD) challenges traditional curricula and formal schooling in important ways. ESD requires systemic thinking, interdisciplinarity and is strengthened through the contributions of all disciplines. As with any transformative societal and technological shift, new questions arise when educators are required to…

  3. Civic Education for Sustainable Development

    ERIC Educational Resources Information Center

    Ohlmeier, Bernhard

    2015-01-01

    Education for sustainable development (ESD) often fails to consider the political dimension. To address this gap, this paper focuses on a specific political approach to ESD. The model presented is derived from the four sustainable growth targets of German Development Policy. Instead of relying on a neo-classical or neo-liberal economic paradigm,…

  4. Education for Sustainable Development in Vietnam: Lessons Learned from Teacher Education

    ERIC Educational Resources Information Center

    Kieu, Thi Kinh; Singer, Jane; Gannon, Tracey Jean

    2016-01-01

    Purpose: The purpose of this paper is to identify challenges in education for sustainable development (ESD) implementation in teacher education institutions (TEIs) in Vietnam and propose some appropriate solutions to advance ESD in training teachers toward sustainability. Design/methodology/approach The authors interviewed ten lecturers and 75…

  5. Turkish Student Science Teachers' Conceptions of Sustainable Development: A Phenomenography

    ERIC Educational Resources Information Center

    Kilinc, Ahmet; Aydin, Abdullah

    2013-01-01

    In creating a society whose citizens have sustainable lifestyles, education for sustainable development (ESD) plays a key role. However, the concept of sustainable development (SD) has developed independently from the input of educators; therefore, ESD presents current teachers with many challenges. At this point, understanding how stakeholders in…

  6. Integration of Sustainability in Engineering Education: Why Is PBL an Answer?

    ERIC Educational Resources Information Center

    Guerra, Aida

    2017-01-01

    Purpose: Education for sustainable development (ESD) is one of the challenges engineering education currently faces. Engineering education needs to revise and change its curriculum to integrate ESD principles and knowledge. Problem based learning (PBL) has been one of the main learning pedagogies used to integrate sustainability in engineering…

  7. Peace Education, ESD and the Earth Charter: Interconnections and Synergies

    ERIC Educational Resources Information Center

    Toh, Swee-Hin; Cawagas, Virginia Floresca

    2010-01-01

    This article provides a review of how the values and principles of the Earth Charter initiative relate to two specific innovative movements of educational transformation, namely peace education and education for sustainable development (ESD). The interconnections and synergies between these movements and the Earth Charter are highlighted.…

  8. Effects of Contextual Factors on ESD in Teacher Education

    ERIC Educational Resources Information Center

    Atmaca, Çagla

    2017-01-01

    Education for sustainable development (ESD) guides and empowers educators to reshape their thinking style and move towards a sustainable future. It has attracted a lot of attention and been studied in different perspectives. However, contextual factors have not been studied in relation to sustainable development for teacher education. Therefore,…

  9. Globalisation and Education for Sustainable Development: Emancipation from Context and Meaning

    ERIC Educational Resources Information Center

    Bengtsson, Stefan L.; Östman, Leif O.

    2013-01-01

    This article tries to contribute to the critical debate on the ideological and globalising potential of education for sustainable development (ESD), which exists in the research field of environmental education, by highlighting potential contradictions in the argumentation for ESD's ideological and globalising tendency. Further, the authors…

  10. When Businesses Go to School: Neoliberalism and Education for Sustainable Development

    ERIC Educational Resources Information Center

    Manteaw, Bob Offei

    2008-01-01

    This paper foregrounds education for sustainable development (ESD) and corporate social responsibility (CSR) as emergent discourses that need conscious efforts to align their ideals. While it explores the capacity of ESD to make significant contribution towards educational thinking and practice, it does so recognising that current neoliberalists'…

  11. Refractive Changes Induced by Spherical Aberration in Laser Correction Procedures: An Adaptive Optics Study.

    PubMed

    Amigó, Alfredo; Martinez-Sorribes, Paula; Recuerda, Margarita

    2017-07-01

    To study the effect on vision of induced negative and positive spherical aberration within the range of laser vision correction procedures. In 10 eyes (mean age: 35.8 years) under cyclopegic conditions, spherical aberration values from -0.75 to +0.75 µm in 0.25-µm steps were induced by an adaptive optics system. Astigmatism and spherical refraction were corrected, whereas the other natural aberrations remained untouched. Visual acuity, depth of focus defined as the interval of vision for which the target was still perceived acceptable, contrast sensitivity, and change in spherical refraction associated with the variation in pupil diameter from 6 to 2.5 mm were measured. A refractive change of 1.60 D/µm of induced spherical aberration was obtained. Emmetropic eyes became myopic when positive spherical aberration was induced and hyperopic when negative spherical aberration was induced (R 2 = 81%). There were weak correlations between spherical aberration and visual acuity or depth of focus (R 2 = 2% and 3%, respectively). Contrast sensitivity worsened with the increment of spherical aberration (R 2 = 59%). When pupil size decreased, emmetropic eyes became hyperopic when preexisting spherical aberration was positive and myopic when spherical aberration was negative, with an average refractive change of 0.60 D/µm of spherical aberration (R 2 = 54%). An inverse linear correlation exists between the refractive state of the eye and spherical aberration induced within the range of laser vision correction. Small values of spherical aberration do not worsen visual acuity or depth of focus, but positive spherical aberration may induce night myopia. In addition, the changes in spherical refraction when the pupil constricts may worsen near vision when positive spherical aberration is induced or improve it when spherical aberration is negative. [J Refract Surg. 2017;33(7):470-474.]. Copyright 2017, SLACK Incorporated.

  12. Rigid spherical particles in highly turbulent Taylor-Couette flow

    NASA Astrophysics Data System (ADS)

    Bakhuis, Dennis; Verschoof, Ruben A.; Mathai, Varghese; Huisman, Sander G.; Lohse, Detlef; Sun, Chao

    2016-11-01

    Many industrial and maritime processes are subject to enormous frictional losses. Reducing these losses even slightly will already lead to large financial and environmental benefits. The understanding of the underlying physical mechanism of frictional drag reduction is still limited, for example, in bubbly drag reduction there is an ongoing debate whether deformability and bubble size are the key parameters. In this experimental study we report high precision torque measurements using rigid non-deformable spherical particles in highly turbulent Taylor-Couette flow with Reynolds numbers up to 2 ×106 . The particles are made of polystyrene with an average density of 1.036 g cm-3 and three different diameters: 8mm, 4mm, and 1.5mm. Particle volume fractions of up to 6% were used. By varying the particle diameter, density ratio of the particles and the working fluid, and volume fraction of the particles, the effect on the torque is compared to the single phase case. These systematic measurements show that adding rigid spherical particles only results in very minor drag reduction. This work is financially supported by Netherlands Organisation for Scientific Research (NWO) by VIDI Grant Number 13477.

  13. The efficiency of aspheric intraocular lens according to biometric measurements.

    PubMed

    Whang, Woong-Joo; Piao, Junjie; Yoo, Young-Sik; Joo, Choun-Ki; Yoon, Geunyoung

    2017-01-01

    To analyze internal spherical aberration in pseudophakic eyes that underwent aspheric intraocular lens (IOL) implantation, and to investigate the relationships between biometric data and the effectiveness of aspheric IOL implantation. This retrospective study included 40 eyes of 40 patients who underwent implantation of an IOL having a negative spherical aberration of -0.20 μm (CT ASPHINA 509M; Carl Zeiss Meditec Inc., Germany). The IOLMaster (version 5.0; Carl Zeiss AG, Germany) was used for preoperative biometric measurements (axial length, anterior chamber depth, central corneal power) and the measurement of postoperative anterior chamber depth. The spherical aberrations were measured preoperatively and 3 months postoperatively using the iTrace (Tracey Technologies, Houston, TX, USA) at a pupil diameter of 5.0 mm. We investigated the relationships between preoperative biometric data and postoperative internal spherical aberration, and compared biometric measurements between 2 subgroups stratified according to internal spherical aberration (spherical aberration ≤ -0.06 μm vs. spherical aberration > -0.06 μm). The mean postoperative internal spherical aberration was -0.087 ± 0.063 μm. Preoperative axial length and residual total spherical aberration showed statistically significant correlations with internal spherical aberration (p = 0.041, 0.002). Preoperative axial length, postoperative anterior chamber depth, IOL power, and residual spherical aberration showed significant differences between the 2 subgroups stratified according to internal spherical aberration (p = 0.020, 0.029, 0.048, 0.041 respectively). The corrective effect of an aspheric IOL is influenced by preoperative axial length and postoperative anterior chamber depth. Not only the amount of negative spherical aberration on the IOL surface but also the preoperative axial length should be considered to optimize spherical aberration after aspheric IOL implantation.

  14. BIMOS transistor solutions for ESD protection in FD-SOI UTBB CMOS technology

    NASA Astrophysics Data System (ADS)

    Galy, Philippe; Athanasiou, S.; Cristoloveanu, S.

    2016-01-01

    We evaluate the Electro-Static Discharge (ESD) protection capability of BIpolar MOS (BIMOS) transistors integrated in ultrathin silicon film for 28 nm Fully Depleted SOI (FD-SOI) Ultra Thin Body and BOX (UTBB) high-k metal gate technology. Using as a reference our measurements in hybrid bulk-SOI structures, we extend the BIMOS design towards the ultrathin silicon film. Detailed study and pragmatic evaluations are done based on 3D TCAD simulation with standard physical models using Average Current Slope (ACS) method and quasi-static DC stress (Average Voltage Slope AVS method). These preliminary 3D TACD results are very encouraging in terms of ESD protection efficiency in advanced FD-SOI CMOS.

  15. Determination of Graphite-Liquid-Vapor Triple Point by Laser Heating

    DTIC Science & Technology

    1976-01-30

    difficulties in the temperature measure- ments, which were made with an optical pyrometer . He considered that the failure of graphite rod was caused by...temperature measurements were made with a calibrated optical pyrometer . Spherical shiny frozen droplets of graphite, 1 to 3 mm in diameter, indicated...0.8 mm in diameter and 10 mm long in argon until failure by rupture occurred. They measured the tempera- ture with a two-color pyrometer . The

  16. Viscosity, density, and thermal conductivity of aluminum oxide and zinc oxide nanolubricants

    PubMed Central

    Kedzierski, M.A.; Brignoli, R.; Quine, K.T.; Brown, J.S.

    2017-01-01

    This paper presents liquid kinematic viscosity, density, and thermal conductivity measurements of eleven different synthetic polyolester-based nanoparticle nanolubricants (dispersions) at atmospheric pressure over the temperature range 288 K to 318 K. Aluminum oxide (Al2O3) and zinc oxide (ZnO) nanoparticles with nominal diameters of 127 nm and 135 nm, respectively, were investigated. A good dispersion of the spherical and non-spherical nanoparticles in the lubricant was maintained with a surfactant. Viscosity, density, and thermal conductivity measurements were made for the neat lubricant along with eleven nanolubricants with differing nanoparticle and surfactant mass fractions. Existing models were used to predict kinematic viscosity (±20%), thermal conductivity (±1%), and specific volume (±6%) of the nanolubricant as a function of temperature, nanoparticle mass fraction, surfactant mass fraction, and nanoparticle diameter. The liquid viscosity, density and thermal conductivity were shown to increase with respect to increasing nanoparticle mass fraction. PMID:28736463

  17. Reviewing Strategies in/for ESD Policy Engagement: Agency Reclaimed

    ERIC Educational Resources Information Center

    Lotz-Sisitka, Heila

    2016-01-01

    In this response article, I draw on critical realist perspectives to engage with the argument put forward in Bengtsson's study, which sees agency as an ontological necessity for Education for Sustainable Development (ESD) policy engagement. Bengtsson supports a notion of the logic of contingent action over the logic of power as dominance,…

  18. The Collaborative Production of Meaningful Measure(ment)s: Preliminary Insights into a Work in Progress

    ERIC Educational Resources Information Center

    Bormann, Inka; Michelsen, Gerd

    2010-01-01

    This article introduces a tri-national research and development project which aims to develop indicators for the cross-sectoral and interdisciplinary educational task "education for sustainable development" (ESD). These indicators are meant to help monitor the implementation of ESD efforts in schools and institutions of higher education…

  19. Children's Voices about the State of the Earth

    ERIC Educational Resources Information Center

    Engdahl, Ingrid; Rabusicova, Milada

    2011-01-01

    This article presents a large project on Education for Sustainable Development (ESD). The project was organised by OMEP, the World Organisation for Early Childhood Education, where the authors were the appointed as project coordinators. The purpose of ESD is to reorient education towards sustainability. The aims of the project were to gather…

  20. Computation of an ESD-induced E-field Envirnoment and Definition of a Current Injector Test set-up at Equipment Level

    NASA Astrophysics Data System (ADS)

    Marque, J. P.; Issac, F.; Parmantier, J. P.; Bertuol, S.

    1998-11-01

    The ESD-induced electromagnetic field on a S/C is computed using the 3D PIC code GEODE. Typical E-field waveforms are deduced and a new susceptibility test at equipment level is proposed as an alternative to the plane wave approach.

  1. Functions, Use and Effects of Embedded Support Devices in Printed Distance Learning Materials.

    ERIC Educational Resources Information Center

    Martens, Rob; And Others

    1996-01-01

    To support distance learning, printed materials for the course are enriched with embedded support devices (ESD) such as schemes, illustrations, examples, questions, or margin texts. Results of 3 studies involving 900 Dutch university students indicated that students used and appreciated ESD, and that they led to better study results. (SLD)

  2. Learning Our Way to Sustainability

    ERIC Educational Resources Information Center

    Wals, Arjen E. J.

    2011-01-01

    Should environmental education (EE) and education for sustainable development (ESD) try to change students' behaviours or should it focus on capacity building and critical thinking? The latter is more likely to lead to a citizenry that can examine new challenges and act wisely. New forms of learning are entering the arena of EE and ESD such as…

  3. Transformative Sustainability Learning: Cultivating a Tree-Planting Ethos in Western Kenya

    ERIC Educational Resources Information Center

    Bull, Marijoan

    2013-01-01

    Given the fundamental objective of ESD--perspective change--it is increasingly being aligned with the theoretical foundation of Mezirow's Transformative Learning. In 2008, Sipos et al. built upon this connection by proposing a matrix of learning objectives to assess ESD in formal settings. These objectives, grouped under the title of…

  4. Education for Sustainable Development in South Africa: A Model Case Scenario

    ERIC Educational Resources Information Center

    Teise, K.; le Roux, A.

    2016-01-01

    Education for Sustainable Development (ESD) is an educational approach that, by being a catalyst of social change, promotes sustainability. Although South African education policy and practice appear to be oriented towards ESD, the concept is contested, and ragged with ambiguity and vagueness. Because the transformation of South African education…

  5. Criteria and Indicators as Negotiated Knowledge and the Challenge of Transfer

    ERIC Educational Resources Information Center

    Bormann, Inka

    2007-01-01

    This paper aims to understand the effects on which criteria and indicators for (education for) sustainable development [(E)SD] are based in terms of knowledge transfer. Therefore, (E)SD criteria and indicators in general are regarded as negotiated and established knowledge, incorporating expectations. As such, this knowledge can be spread…

  6. Practical Pedagogy for Embedding ESD in Science, Technology, Engineering and Mathematics Curricula

    ERIC Educational Resources Information Center

    Hopkinson, Peter; James, Peter

    2010-01-01

    Purpose--The purpose of this paper is to review and highlight some recent examples of embedding education for sustainable development (ESD), within science and related curricula in ways that are meaningful and relevant to staff and students and reflect on different embedding strategies and discourses. Design/methodology/approach--A review of…

  7. Opportunities for Teaching Sustainable Development through the Chemistry Component of CAPS Physical Sciences

    ERIC Educational Resources Information Center

    Tsakeni, Maria

    2018-01-01

    The realisation that education may, in part, have contributed to non-sustainable environmental practices warrants rethinking about what learners experience at school. One approach could involve the promotion of education for sustainable development (ESD). This study analysed the opportunities to integrate ESD presented by the chemistry component…

  8. Earth Charter, ESD and Chinese Philosophies

    ERIC Educational Resources Information Center

    Liu, Yunhua; Constable, Alicia

    2010-01-01

    This article examines the relationship between the Earth Charter and education for sustainable development (ESD), as part of the UN Decade of Education for Sustainable Development. The areas of shared interest between the two are assessed and the invaluable nature of the Earth Charter as a resource outlining global values and principles for a…

  9. Accounting Manual for Educational Service Districts in the State of Washington

    ERIC Educational Resources Information Center

    Lunghofer, Daniel S.

    2010-01-01

    This manual provides principles that are an integral part of the accounting requirements for educational service districts (ESDs) in the state of Washington. They are in conformance with generally accepted accounting principles, except where referenced in the ESD principles that follow. This manual provides guidance on the following topics:(1)…

  10. Management Information System for ESD Program Offices.

    DTIC Science & Technology

    1978-03-01

    Management Information System (MIS) functional requirements for the ESD Program Office are defined in terms of the Computer-Aided Design and Specification Tool. The development of the computer data base and a description of the MIS structure is included in the report. This report addresses management areas such as cost/budgeting, scheduling, tracking capabilities, and ECP

  11. Education for Sustainable Development: A Movement towards Pedagogies of Civic Compassion

    ERIC Educational Resources Information Center

    Warwick, Paul

    2016-01-01

    This article explores the moral imperative for a renewed vision of schooling in the twenty-first century, from the standpoint of Education for Sustainable Development (ESD). ESD advocates for teaching and learning spaces underpinned by civic compassion in the sense of "an active concern for well-being". This paradigm of education seeks…

  12. The Co-Evolution of ESD and EE

    ERIC Educational Resources Information Center

    Monroe, Martha C.

    2012-01-01

    William B. Stapp, a major author of the founding documents of environmental education (EE), foreshadowed the triple concerns of education for sustainable development (ESD) with environment, social justice and economic health. Yet EE in the USA tended to follow the advocacy orientation of the environmental movement of the 1970s and later, following…

  13. Exploring the Current Position of ESD in UK Higher Education Institutions

    ERIC Educational Resources Information Center

    Fiselier, Evelien S.; Longhurst, James W. S.; Gough, Georgina K.

    2018-01-01

    Purpose: The purpose of this paper is to consider the position of education for sustainable development in the UK Higher Education (HE) sector with respect to the Quality Assurance Agency (QAA) and Higher Education Academy (HEA) Guidance for education for sustainable development (ESD). Design/methodology/approach: By means of a mixed-method…

  14. Professional Development of University Educators in ESD: A Study from Pedagogical Styles

    ERIC Educational Resources Information Center

    Callejas Restrepo, Maria Mercedes; Blanco-Portela, Norka; Ladino-Ospina, Yolanda; Tuay Sigua, Rosa Nidia; Vargas, Kenneth Ochoa

    2017-01-01

    Purpose: The aim of this paper is to present a vision for university educator professional development, based on self-analysis of pedagogical styles and production of knowledge about the practices that promote education for sustainable development (ESD). Design/methodology/approach: The "STSE" course is part of the department's…

  15. Building ESD in Latin America

    ERIC Educational Resources Information Center

    Journal of Education for Sustainable Development, 2007

    2007-01-01

    To encourage efforts for furthering the UN DESD agenda in Latin America, a meeting titled "Building Education for Sustainable Development" was held in Costa Rica from 31 October to 2 November 2006. Plenary sessions were interspersed with working groups to look at how ESD can be integrated in formal and non-formal education systems, and…

  16. A Collaborative Action Research Project towards Embedding ESD within the Higher Education Curriculum

    ERIC Educational Resources Information Center

    Cebrián, Gisela

    2017-01-01

    Purpose: This paper aims to present a collaborative action research project conducted at the University of Southampton with the aim to promote curriculum and professional development in education for sustainable development (ESD) and learn from everyday practices of academics. Design/methodology/approach: An action research approach guided by…

  17. How Education Can Be Used to Improve Sustainability Knowledge and Thinking among Teenagers

    ERIC Educational Resources Information Center

    Brazier, Randolph James

    2014-01-01

    Significant progress has been made with respect to Education for Sustainable Development (ESD) in tertiary education institutions, particularly universities. There are also examples of ways in which sustainability has been incorporated into secondary schools and curricula, but with varying levels of success. ESD that has been incorporated in…

  18. ESD as a Means to Strengthen the Sustainable Management of Marginal Drylands in Egypt

    ERIC Educational Resources Information Center

    Salem, Boshra B.

    2012-01-01

    The objective of this article is to present results of and lessons learnt from implementing education for sustainable development (ESD) in marginal drylands, based on experiences from the TEMPUS IV project, Education for Sustainable Development beyond the Campus (EDUCAMP), in Egypt and the multinational project, Sustainable Development of Marginal…

  19. Endoscopic submucosal dissection for esophageal granular cell tumor using the clutch cutter

    PubMed Central

    Komori, Keishi; Akahoshi, Kazuya; Tanaka, Yoshimasa; Motomura, Yasuaki; Kubokawa, Masaru; Itaba, Soichi; Hisano, Terumasa; Osoegawa, Takashi; Nakama, Naotaka; Iwao, Risa; Oya, Masafumi; Nakamura, Kazuhiko

    2012-01-01

    Endoscopic submucosal dissection (ESD) with a knife is a technically demanding procedure associated with a high complication rate. The shortcomings of this method are the deficiencies of fixing the knife to the target lesion, and of compressing it. These shortcomings can lead to major complications such as perforation and bleeding. To reduce the risk of complications related to ESD, we developed a new grasping type scissors forceps (Clutch Cutter®, Fujifilm, Japan) which can grasp and incise the targeted tissue using an electrosurgical current. Esophagogastroduodenoscopy on a 59-year-old Japanese man revealed a 16mm esophageal submucosal nodule with central depression. Endoscopic ultrasonography demonstrated a hypoechoic solid tumor limited to the submucosa without lymph node involvement. The histologic diagnosis of the specimen obtained by biopsy was granular cell tumor. It was safely and accurately resected without unexpected incision by ESD using the CC. No delayed hemorrhage or perforation occurred. Histological examination confirmed that the granular cell tumor was completely excised with negative resection margin.We report herein a case of esophageal granular cell tumor successfully treated by an ESD technique using the CC. PMID:22267979

  20. Modelling of influence of spherical aberration coefficients on depth of focus of optical systems

    NASA Astrophysics Data System (ADS)

    Pokorný, Petr; Šmejkal, Filip; Kulmon, Pavel; Mikš, Antonín.; Novák, Jiří; Novák, Pavel

    2017-06-01

    This contribution describes how to model the influence of spherical aberration coefficients on the depth of focus of optical systems. Analytical formulas for the calculation of beam's caustics are presented. The conditions for aberration coefficients are derived for two cases when we require that either the Strehl definition or the gyration radius should be the identical in two symmetrically placed planes with respect to the paraxial image plane. One can calculate the maximum depth of focus and the minimum diameter of the circle of confusion of the optical system corresponding to chosen conditions. This contribution helps to understand how spherical aberration may affect the depth of focus and how to design such an optical system with the required depth of focus. One can perform computer modelling and design of the optical system and its spherical aberration in order to achieve the required depth of focus.

  1. Method of Manufacturing a Light Emitting, Photovoltaic or Other Electronic Apparatus and System

    NASA Technical Reports Server (NTRS)

    Blanchard, Richard A. (Inventor); Fuller, Kirk A. (Inventor); Ray, William Johnstone (Inventor); Shotton, Neil O. (Inventor); Frazier, Donald Odell (Inventor); Lowenthal, Mark D. (Inventor); Lewandowski, Mark Allan (Inventor)

    2013-01-01

    The present invention provides a method of manufacturing an electronic apparatus, such as a lighting device having light emitting diodes (LEDs) or a power generating device having photovoltaic diodes. The exemplary method includes forming at least one first conductor coupled to a base; coupling a plurality of substantially spherical substrate particles to the at least one first conductor; converting the substrate particles into a plurality of substantially spherical diodes; forming at least one second conductor coupled to the substantially spherical diodes; and depositing or attaching a plurality of substantially spherical lenses suspended in a first polymer. The lenses and the suspending polymer have different indices of refraction. In some embodiments, the lenses and diodes have a ratio of mean diameters or lengths between about 10:1 and 2:1. In various embodiments, the forming, coupling and converting steps are performed by or through a printing process.

  2. Radiation risk assessment in neonatal radiographic examinations of the chest and abdomen: a clinical and Monte Carlo dosimetry study

    NASA Astrophysics Data System (ADS)

    Makri, T.; Yakoumakis, E.; Papadopoulou, D.; Gialousis, G.; Theodoropoulos, V.; Sandilos, P.; Georgiou, E.

    2006-10-01

    Seeking to assess the radiation risk associated with radiological examinations in neonatal intensive care units, thermo-luminescence dosimetry was used for the measurement of entrance surface dose (ESD) in 44 AP chest and 28 AP combined chest-abdominal exposures of a sample of 60 neonates. The mean values of ESD were found to be equal to 44 ± 16 µGy and 43 ± 19 µGy, respectively. The MCNP-4C2 code with a mathematical phantom simulating a neonate and appropriate x-ray energy spectra were employed for the simulation of the AP chest and AP combined chest-abdominal exposures. Equivalent organ dose per unit ESD and energy imparted per unit ESD calculations are presented in tabular form. Combined with ESD measurements, these calculations yield an effective dose of 10.2 ± 3.7 µSv, regardless of sex, and an imparted energy of 18.5 ± 6.7 µJ for the chest radiograph. The corresponding results for the combined chest-abdominal examination are 14.7 ± 7.6 µSv (males)/17.2 ± 7.6 µSv (females) and 29.7 ± 13.2 µJ. The calculated total risk per radiograph was low, ranging between 1.7 and 2.9 per million neonates, per film, and being slightly higher for females. Results of this study are in good agreement with previous studies, especially in view of the diversity met in the calculation methods.

  3. Ultrasonic versus monopolar energy-based surgical devices in terms of surgical smoke and lateral thermal damage (ULMOST): a randomized controlled trial.

    PubMed

    Choi, Chahien; Do, In-Gu; Song, Taejong

    2018-04-09

    The purpose of this study was to compare the degree of surgical smoke or vapor and lateral thermal damage caused by two different energy-based surgical devices (ESDs) used in colpotomy during total laparoscopic hysterectomy. Patients undergoing laparoscopic hysterectomy were randomly assigned to an ultrasonic ESD group (n = 20) or monopolar ESD group (n = 20). Colpotomy was performed using the assigned ESD. The degree of surgical smoke or vapor obstructing the laparoscopic view was assessed by two independent reviewers using a 5-point Likert scale, in which a higher score indicates worse visibility. The degree of the lateral thermal damage was measured as the width from the point of instrument application to the margins of the unchanged nearby tissue using a light microscope. The baseline characteristics did not statistically differ between the two groups. The degree of surgical smoke or vapor obstructing vision was 1.2 ± 0.8 points in the ultrasonic group and 3.9 ± 0.7 points in the monopolar groups (p < 0.001). The lateral thermal damage was significantly increased in the monopolar group compared to in the ultrasound group (1500 µm [1200-2500 µm] vs. 950 µm [650-1725 µm], p = 0.037). Ultrasonic ESD had better laparoscopic visibility and caused less lateral thermal damage during colpotomy compared to monopolar device.

  4. Epigenetic modification and inheritance in sexual reversal of fish.

    PubMed

    Shao, Changwei; Li, Qiye; Chen, Songlin; Zhang, Pei; Lian, Jinmin; Hu, Qiaomu; Sun, Bing; Jin, Lijun; Liu, Shanshan; Wang, Zongji; Zhao, Hongmei; Jin, Zonghui; Liang, Zhuo; Li, Yangzhen; Zheng, Qiumei; Zhang, Yong; Wang, Jun; Zhang, Guojie

    2014-04-01

    Environmental sex determination (ESD) occurs in divergent, phylogenetically unrelated taxa, and in some species, co-occurs with genetic sex determination (GSD) mechanisms. Although epigenetic regulation in response to environmental effects has long been proposed to be associated with ESD, a systemic analysis on epigenetic regulation of ESD is still lacking. Using half-smooth tongue sole (Cynoglossus semilaevis) as a model-a marine fish that has both ZW chromosomal GSD and temperature-dependent ESD-we investigated the role of DNA methylation in transition from GSD to ESD. Comparative analysis of the gonadal DNA methylomes of pseudomale, female, and normal male fish revealed that genes in the sex determination pathways are the major targets of substantial methylation modification during sexual reversal. Methylation modification in pseudomales is globally inherited in their ZW offspring, which can naturally develop into pseudomales without temperature incubation. Transcriptome analysis revealed that dosage compensation occurs in a restricted, methylated cytosine enriched Z chromosomal region in pseudomale testes, achieving equal expression level in normal male testes. In contrast, female-specific W chromosomal genes are suppressed in pseudomales by methylation regulation. We conclude that epigenetic regulation plays multiple crucial roles in sexual reversal of tongue sole fish. We also offer the first clues on the mechanisms behind gene dosage balancing in an organism that undergoes sexual reversal. Finally, we suggest a causal link between the bias sex chromosome assortment in the offspring of a pseudomale family and the transgenerational epigenetic inheritance of sexual reversal in tongue sole fish.

  5. Clinical outcomes of endoscopic submucosal dissection for early gastric cancer in remnant stomach or gastric tube.

    PubMed

    Nishide, N; Ono, H; Kakushima, N; Takizawa, K; Tanaka, M; Matsubayashi, H; Yamaguchi, Y

    2012-06-01

    Little information exists regarding the optimal treatment of early gastric cancer (EGC) in a remnant stomach or gastric tube. The aim of this study was to assess the feasibility and clinical outcomes of endoscopic submucosal dissection (ESD) for EGC in a remnant stomach and gastric tube. Between September 2002 and December 2009, ESD was performed in 62 lesions in 59 patients with EGC in a remnant stomach (48 lesions) or gastric tube (14 lesions). Clinicopathological data were retrieved retrospectively to assess the en bloc resection rate, complications, and outcomes. Treatment results were assessed according to the indications for endoscopic resection, and were compared with those of ESD performed in a whole stomach during the same study period. The en bloc resection rates for lesions within the standard and expanded indication were 100 % and 93 %, respectively. Postoperative bleeding occurred in five patients (8 %). The perforation rate was significantly higher (18 %, 11 /62) than that of ESD in a whole stomach (5 %, 69 /1479). Among the perforation cases, eight lesions involved the anastomotic site or stump line, and ulcerative changes were observed in five lesions. The 3-year overall survival rate was 85 %, with eight deaths due to other causes and no deaths from gastric cancer. A high en bloc resection rate was achieved by ESD for EGC in a remnant stomach or gastric tube; however, this procedure is still technically demanding due to the high complication rate of perforation. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Efficacy of treatment with rebamipide for endoscopic submucosal dissection-induced ulcers

    PubMed Central

    Takayama, Masaki; Matsui, Shigenaga; Kawasaki, Masanori; Asakuma, Yutaka; Sakurai, Toshiharu; Kashida, Hiroshi; Kudo, Masatoshi

    2013-01-01

    AIM: To prospectively compare the healing rates of endoscopic submucosal dissection (ESD)-induced ulcers treated with either a proton-pump inhibitor (PPI) or rebamipide. METHODS: We examined 90 patients with early gastric cancer who had undergone ESD. All patients were administered an intravenous infusion of the PPI lansoprazole (20 mg) every 12 h for 2 d, followed by oral administration of lansoprazole (30 mg/d, 5 d). After 7-d treatment, the patients were randomly assigned to 2 groups and received either lansoprazole (30 mg/d orally, n = 45; PPI group) or rebamipide (300 mg orally, three times a day; n = 45; rebamipide group). At 4 and 8 wk after ESD, the ulcer outcomes in the 2 groups were compared. RESULTS: No significant differences were noted in patient age, underlying disease, tumor location, Helicobacter pylori infection rate, or ESD-induced ulcer size between the 2 groups. At both 4 and 8 wk, the healing rates of ESD-induced ulcers were similar in the PPI-treated and the rebamipide-treated patients (4 wk: PPI, 27.2%; rebamipide, 33.3%; P = 0.5341; 8 wk: PPI, 90.9%; rebamipide, 93.3%; P = 0.6710). At 8 wk, the rates of granulation lesions following ulcer healing were significantly higher in the PPI-treated group (13.6%) than in the rebamipide-treated group (0.0%; P = 0.0103). Ulcer-related symptoms were similar in the 2 treatment groups at 8 wk. The medication cost of 8-wk treatment with the PPI was 10945 yen vs 4889 yen for rebamipide. No ulcer bleeding or complications due to the drugs were observed in either treatment group. CONCLUSION: The healing rate of ESD-induced ulcers was similar with rebamipide or PPI treatment; however, rebamipide treatment is more cost-effective and prevents granulation lesions following ulcer healing. PMID:24039365

  7. Cross sectional study of serum selenium concentration and esophageal squamous dysplasia in western Kenya.

    PubMed

    Pritchett, Natalie R; Burgert, Stephen L; Murphy, Gwen A; Brockman, John D; White, Russell E; Lando, Justus; Chepkwony, Robert; Topazian, Mark D; Abnet, Christian C; Dawsey, Sanford M; Mwachiro, Michael M

    2017-12-08

    Low serum selenium status has been associated with increased risk of esophageal squamous cell carcinoma (ESCC). East Africa is a region of high ESCC incidence and is known to have low soil selenium levels, but this association has not previously been evaluated. In this study we assessed the association of serum selenium concentration and the prevalence of esophageal squamous dysplasia (ESD), the precursor lesion of ESCC, in a cross-sectional study of subjects from Bomet, Kenya. 294 asymptomatic adult residents of Bomet, Kenya completed questionnaires and underwent endoscopy with Lugol's iodine staining and biopsy for detection of ESD. Serum selenium concentrations were measured by instrumental neutron activation analysis. Odds ratios (OR) and confidence intervals (95% CI) for associations between serum selenium and ESD were calculated using unconditional logistic regression. The mean serum selenium concentration was 85.5 (±28.3) μg/L. Forty-two ESD cases were identified (14% of those screened), including 5 (12%) in selenium quartile 1 (Q1), 5 (12%) in Q2, 15 (36%) in Q3, and 17 (40%) in Q4. Higher serum selenium was associated with prevalence of ESD (Q4 vs Q1: OR: 3.03; 95% CI: 1.05-8.74) and this association remained after adjusting for potential confounders (Q4 vs Q1: OR: 3.87; 95% CI: 1.06-14.19). This is the first study to evaluate the association of serum selenium concentration and esophageal squamous dysplasia in an African population at high risk for ESCC. We found a positive association between higher serum selenium concentration and prevalence of ESD, an association contrary to our original hypothesis. Further work is needed to better understand the role of selenium in the etiology of ESCC in this region, and to develop effective ESCC prevention and control strategies.

  8. The baseline pressure of intracranial pressure (ICP) sensors can be altered by electrostatic discharges.

    PubMed

    Eide, Per K; Bakken, André

    2011-08-22

    The monitoring of intracranial pressure (ICP) has a crucial role in the surveillance of patients with brain injury. During long-term monitoring of ICP, we have seen spontaneous shifts in baseline pressure (ICP sensor zero point), which are of technical and not physiological origin. The aim of the present study was to explore whether or not baseline pressures of ICP sensors can be affected by electrostatics discharges (ESD's), when ESD's are delivered at clinically relevant magnitudes. We performed bench-testing of a set of commercial ICP sensors. In our experimental setup, the ICP sensor was placed in a container with 0.9% NaCl solution. A test person was charged 0.5-10 kV, and then delivered ESD's to the sensor by touching a metal rod that was located in the container. The continuous pressure signals were recorded continuously before/after the ESD's, and the pressure readings were stored digitally using a computerized system A total of 57 sensors were tested, including 25 Codman ICP sensors and 32 Raumedic sensors. When charging the test person in the range 0.5-10 kV, typically ESD's in the range 0.5-5 kV peak pulse were delivered to the ICP sensor. Alterations in baseline pressure ≥ 2 mmHg was seen in 24 of 25 (96%) Codman sensors and in 17 of 32 (53%) Raumedic sensors. Lasting changes in baseline pressure > 10 mmHg that in the clinical setting would affect patient management, were seen frequently for both sensor types. The changes in baseline pressure were either characterized by sudden shifts or gradual drifts in baseline pressure. The baseline pressures of commercial solid ICP sensors can be altered by ESD's at discharge magnitudes that are clinically relevant. Shifts in baseline pressure change the ICP levels visualised to the physician on the monitor screen, and thereby reveal wrong ICP values, which likely represent a severe risk to the patient.

  9. The baseline pressure of intracranial pressure (ICP) sensors can be altered by electrostatic discharges

    PubMed Central

    2011-01-01

    Background The monitoring of intracranial pressure (ICP) has a crucial role in the surveillance of patients with brain injury. During long-term monitoring of ICP, we have seen spontaneous shifts in baseline pressure (ICP sensor zero point), which are of technical and not physiological origin. The aim of the present study was to explore whether or not baseline pressures of ICP sensors can be affected by electrostatics discharges (ESD's), when ESD's are delivered at clinically relevant magnitudes. Methods We performed bench-testing of a set of commercial ICP sensors. In our experimental setup, the ICP sensor was placed in a container with 0.9% NaCl solution. A test person was charged 0.5 - 10 kV, and then delivered ESD's to the sensor by touching a metal rod that was located in the container. The continuous pressure signals were recorded continuously before/after the ESD's, and the pressure readings were stored digitally using a computerized system Results A total of 57 sensors were tested, including 25 Codman ICP sensors and 32 Raumedic sensors. When charging the test person in the range 0.5-10 kV, typically ESD's in the range 0.5 - 5 kV peak pulse were delivered to the ICP sensor. Alterations in baseline pressure ≥ 2 mmHg was seen in 24 of 25 (96%) Codman sensors and in 17 of 32 (53%) Raumedic sensors. Lasting changes in baseline pressure > 10 mmHg that in the clinical setting would affect patient management, were seen frequently for both sensor types. The changes in baseline pressure were either characterized by sudden shifts or gradual drifts in baseline pressure. Conclusions The baseline pressures of commercial solid ICP sensors can be altered by ESD's at discharge magnitudes that are clinically relevant. Shifts in baseline pressure change the ICP levels visualised to the physician on the monitor screen, and thereby reveal wrong ICP values, which likely represent a severe risk to the patient. PMID:21859487

  10. SU-E-P-57: Radiation Doses Assessment to Paediatric Patients for Some Digital Diagnostic Radiology Examination in Emergency Department in Qatar

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abdallah, I; Aly, A; Al Naemi, H

    Purpose: The aim of this study was to evaluate radiation doses to pediatric patients undergoing standard radiographic examinations using Direct Digital Radiography (DDR) in Paediatric emergency center of Hamad General Hospital (HGH) in state of Qatar and compared with regional and international Dose Reference Levels (DRLs). Methods: Entrance Skin Dose (ESD) was measured for 2739 patients for two common X-ray examinations namely: Chest AP/PA, Abdomen. Exposure factors such as kV, mAs and Focal to Skin Distance (FSD) were recorded for each patient. Tube Output was measured for a range of selected kV values. ESD for each individual patient was calculatedmore » using the tube output and the technical exposure factors for each examination. The ESD values were compared with the some international Dose Reference Levels (DRL) for all types of examinations. Results: The most performed procedure during the time of this study was chest PA/PA (85%). The mean ESD values obtained from AP chest, PA chest and AP abdomen ranged 91–120, 80–84 and 209 – 659 µGy per radiograph for different age’s groups respectively. Two protocols have been used for chest AP and PA using different radiological parameters, and the different of ESD values for chest PA and were 41% for 1 years old child, 57% for 5 years old for chest AP. Conclusion: The mean ESD were compared with those found in literature and were found to be comparable. The radiation dose can be reduced more for Chest AP and PA examination by optimization of each investigation and hence more studies are required for this task. The results presented will serve as a baseline data needed for deriving local reference doses for pediatric X-ray examinations in this local department and hence it can be applied in the whole Qatar.« less

  11. Usefulness of IT knife nano for endoscopic submucosal dissection of large colo-rectal lesions.

    PubMed

    Suzuki, T; Hara, T; Kitagawa, Y; Yamaguchi, T

    2016-01-01

    Endoscopic submucosal dissection (ESD) is currently widely conducted for the treatment of early gastrointestinal -cancers. Due to the characteristic anatomy of the large intestine, needle- tip type devices such as Dual knife are mainly used in colorectal ESD. On the other hand, the non- needle-tip type IT knife is a unique device with an insulated tip, and has been reported to be safe, efficacious and speedy when used in gastric ESD. A new model of IT knife, IT knife nano, anticipated to be useful for esophageal and colorectal ESD has become available, but its usefulness has not been reported. Therefore, we performed this study to evaluate the usefulness of IT knife nano for ESD of large colorectal lesions. Previous studies have shown that a tumor size of 40 mm or above significantly prolongs treatment time and is a factor of treatment difficulty. We selected colorectal lesions of 40 mm and above, and compared 32 lesions treated with Dual knife alone before IT knife nano was available (No-IT group) and 40 cases treated with IT knife nano as a second knife after IT knife nano became available (IT group). We assessed en bloc resection rate, complete en bloc resection rate, complication rate and treatment time. The en bloc resection rates in No-IT group and IT group were 100% and 97.5%, respectively, with no significant difference. The respective median treatment time was 70 min and 51 min, and was significantly shortened in IT group (P < 0.05). The respective rates of procedure- related perforation were 3.1% and 0% ; in IT group suggesting a tendency of reduced incidence. Use of IT knife nano in ESD for large colorectal -lesions achieves the same levels of efficacy and safety as conventional device, with the additional merit of shortening treatment time. © Acta Gastro-Enterologica Belgica.

  12. Methyl farnesoate synthesis is necessary for the environmental sex determination in the water flea Daphnia pulex.

    PubMed

    Toyota, Kenji; Miyakawa, Hitoshi; Hiruta, Chizue; Furuta, Kenjiro; Ogino, Yukiko; Shinoda, Tetsuro; Tatarazako, Norihisa; Miyagawa, Shinichi; Shaw, Joseph R; Iguchi, Taisen

    2015-09-01

    Sex-determination systems can be divided into two groups: genotypic sex determination (GSD) and environmental sex determination (ESD). ESD is an adaptive life-history strategy that allows control of sex in response to environmental cues in order to optimize fitness. However, the molecular basis of ESD remains largely unknown. The micro crustacean Daphnia pulex exhibits ESD in response to various external stimuli. Although methyl farnesoate (MF: putative juvenile hormone, JH, in daphnids) has been reported to induce male production in daphnids, the role of MF as a sex-determining factor remains elusive due to the lack of a suitable model system for its study. Here, we establish such a system for ESD studies in D. pulex. The WTN6 strain switches from producing females to producing males in response to the shortened day condition, while the MFP strain only produces females, irrespective of day-length. To clarify whether MF has a novel physiological role as a sex-determining factor in D. pulex, we demonstrate that a MF/JH biosynthesis inhibitor suppressed male production in WTN6 strain reared under the male-inducible condition, shortened day-length. Moreover, we show that juvenile hormone acid O-methyltransferase (JHAMT), a critical enzyme of MF/JH biosynthesis, displays MF-generating activity by catalyzing farnesoic acid. Expression of the JHAMT gene increased significantly just before the MF-sensitive period for male production in the WTN6 strain, but not in the MFP strain, when maintained under male-inducible conditions. These results suggest that MF synthesis regulated by JHAMT is necessary for male offspring production in D. pulex. Our findings provide novel insights into the genetic underpinnings of ESD and they begin to shed light on the physiological function of MF as a male-fate determiner in D. pulex. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. The expansion of endoscopic submucosal dissection in France: A prospective nationwide survey

    PubMed Central

    Barret, Maximilien; Lepilliez, Vincent; Coumaros, Dimitri; Chaussade, Stanislas; Leblanc, Sarah; Ponchon, Thierry; Fumex, Fabien; Chabrun, Edouard; Bauret, Paul; Cellier, Christophe; Coron, Emmanuel; Bichard, Philippe; Bulois, Philippe; Charachon, Antoine; Rahmi, Gabriel; Bellon, Serge; Lerhun, Marc; Arpurt, Jean-Pierre; Koch, Stéphane; Napoleon, Bertrand; Vaillant, Eric; Esch, Anouk; Farhat, Said; Robin, Francoise; Kaddour, Nadira

    2016-01-01

    Introduction Early reports of endoscopic submucosal dissection (ESD) in Europe suggested high complication rates and disappointing outcomes compared to publications from Japan. Since 2008, we have been conducting a nationwide survey to monitor the outcomes and complications of ESD over time. Material and methods All consecutive ESD cases from 14 centers in France were prospectively included in the database. Demographic, procedural, outcome and follow-up data were recorded. The results obtained over three years were compared to previously published data covering the 2008–2010 period. Results Between November 2010 and June 2013, 319 ESD cases performed in 314 patients (62% male, mean (±SD) age 65.4 ± 12) were analyzed and compared to 188 ESD cases in 188 patients (61% male, mean (±SD) age 64.6 ± 13) performed between January 2008 and October 2010. The mean (±SD) lesion size was 39 ± 12 mm in 2010–2013 vs 32.1 ± 21 for 2008–2010 (p = 0.004). En bloc resection improved from 77.1% to 91.7% (p < 0.0001) while R0 en bloc resection remained stable from 72.9% to 71.9% (p = 0.8) over time. Complication rate dropped from 29.2% between 2008 and 2010 to 14.1% between 2010 and 2013 (p < 0.0001), with bleeding decreasing from 11.2% to 4.7% (p = 0.01) and perforations from 18.1% to 8.1% (p = 0.002) over time. No procedure-related mortality was recorded. Conclusions In this multicenter study, ESD achieved high rates of en bloc resection with a significant trend toward better outcomes over time. Improvements in lesion delineation and characterization are still needed to increase R0 resection rates. PMID:28405321

  14. Long-term outcomes of endoscopic submucosal dissection versus surgery in early gastric cancer meeting expanded indication including undifferentiated-type tumors: a criteria-based analysis.

    PubMed

    Lee, Sunpyo; Choi, Kee Don; Han, Minkyu; Na, Hee Kyong; Ahn, Ji Yong; Jung, Kee Wook; Lee, Jeong Hoon; Kim, Do Hoon; Song, Ho June; Lee, Gin Hyug; Yook, Jeong-Hwan; Kim, Byung Sik; Jung, Hwoon-Yong

    2018-05-01

    Endoscopic submucosal dissection (ESD) for early gastric cancer (EGC) meeting the expanded indication is considered investigational. We aimed to compare long-term outcomes of ESD and surgery for EGC in the expanded indication based on each criterion. This study included 1823 consecutive EGC patients meeting expanded indication conditions and treated at a tertiary referral center: 916 and 907 patients underwent surgery or ESD, respectively. The expanded indication included four discrete criteria: (I) intramucosal differentiated tumor, without ulcers, size >2 cm; (II) intramucosal differentiated tumor, with ulcers, size ≤3 cm; (III) intramucosal undifferentiated tumor, without ulcers, size ≤2 cm; and (IV) submucosal invasion <500 μm (sm1), differentiated tumor, size ≤3 cm. We selected 522 patients in each group by propensity score matching and retrospectively evaluated each group. The primary outcome was overall survival (OS); the secondary outcomes were disease-specific survival (DSS), recurrence-free survival (RFS), and treatment-related complications. In all patients and subgroups meeting each criterion, OS and DSS were not significantly different between groups (OS and DSS, all patients: p = 0.354 and p = 0.930; criteria I: p = 0.558 and p = 0.688; criterion II: p = 1.000 and p = 1.000; criterion III: p = 0.750 and p = 0.799; and criterion IV: p = 0.599 and p = 0.871). RFS, in all patients and criterion I, was significantly shorter in the ESD group than in the surgery group (p < 0.001 and p < 0.003, respectively). The surgery group showed higher rates of late and severe treatment-related complications than the ESD group. ESD may be an alternative treatment option to surgery for EGCs meeting expanded indications, including undifferentiated-type tumors.

  15. Evaluating an extended rehabilitation service for stroke patients (EXTRAS): study protocol for a randomised controlled trial.

    PubMed

    Rodgers, Helen; Shaw, Lisa; Cant, Robin; Drummond, Avril; Ford, Gary A; Forster, Anne; Hills, Katie; Howel, Denise; Laverty, Anne-Marie; McKevitt, Christopher; McMeekin, Peter; Price, Christopher

    2015-05-05

    Development of longer term stroke rehabilitation services is limited by lack of evidence of effectiveness for specific interventions and service models. We describe the protocol for a multicentre randomised controlled trial which is evaluating an extended stroke rehabilitation service. The extended service commences when routine 'organised stroke care' (stroke unit and early supported discharge (ESD)) ends. This study is a multicentre randomised controlled trial with health economic and process evaluations. It is set within NHS stroke services which provide ESD. Participants are adults who have experienced a new stroke (and carer if appropriate), discharged from hospital under the care of an ESD team. The intervention group receives an extended stroke rehabilitation service provided for 18 months following completion of ESD. The extended rehabilitation service involves regular contact with a senior ESD team member who leads and coordinates further rehabilitation. Contact is usually by telephone. The control group receives usual stroke care post-ESD. Usual care may involve referral of patients to a range of rehabilitation services upon completion of ESD in accordance with local clinical practice. Randomisation is via a central independent web-based service. The primary outcome is extended activities of daily living (Nottingham Extended Activities of Daily Living Scale) at 24 months post-randomisation. Secondary outcomes (at 12 and 24 months post-randomisation) are health status, quality of life, mood and experience of services for patients, and quality of life, experience of services and carer stress for carers. Resource use and adverse events are also collected. Outcomes are undertaken by a blinded assessor. Implementation and delivery of the extended stroke rehabilitation service will also be described. Semi-structured interviews will be conducted with a subsample of participants and staff to gain insight into perceptions and experiences of rehabilitation services delivered or received. Allowing for 25% attrition, 510 participants are needed to provide 90% power to detect a difference in mean Nottingham Extended Activities of Daily Living Scale score of 6 with a 5% significance level. The provision of longer term support for stroke survivors is currently limited. The results from this trial will inform future stroke service planning and configuration. This trial was registered with ISRCTN (identifier: ISRCTN45203373 ) on 9 August 2012.

  16. Scalable MWIR and LWIR optical system designs employing a large spherical primary mirror and small refractive aberration correctors

    NASA Astrophysics Data System (ADS)

    Beach, David A.

    2001-12-01

    Design variants of a recently developed optical imaging system have been computed for the thermal infrared spectral bands, which offer some advantages for long-range surveillance and astronomy. Only the spherical primary mirror has the full pupil diameter, all other components being sub-diameter, so scaling is possible up to relatively large pupils. Low-cost fabrication is enabled by the prevalence of spherical optical surfaces. Both MWIR and LWIR spectral transmissions are enabled by the choice of corrector materials, the examples given employing germanium and sapphire for 3.5 - 5.5 micrometers and germanium and zinc selenide for 3.5 - 5.5 micrometers and 8 - 12 micrometers passbands. Diffraction at these wavelengths is the main contributor to resolution constraints, so high numerical aperture values are preferred to enable a better match of blur spot diameter to generally available pixel dimensions. The systems described can routinely be designed to have speeds of f/0.8 or faster, while maintaining diffraction-limited performance over useful angular fields. Because the new design system employs a relayed catadioptric, it is possible to make the aperture stop of the system coincident with the window of the detector cryostat, enabling precise radiometric geometry. The central obscuration provides a convenient location for a calibration source, and both this and a mask for secondary spider supports can be included within the detector cold screen structure. Dual-band operation could be enabled by inclusion of a spectral beam splitter prior to a dual relay/imager system.

  17. Optical performance of toric intraocular lenses in the presence of decentration.

    PubMed

    Zhang, Bin; Ma, Jin-Xue; Liu, Dan-Yan; Du, Ying-Hua; Guo, Cong-Rong; Cui, Yue-Xian

    2015-01-01

    To evaluate the optical performance of toric intraocular lenses (IOLs) after decentration and with different pupil diameters, but with the IOL astigmatic axis aligned. Optical performances of toric T5 and SN60AT spherical IOLs after decentration were tested on a theoretical pseudophakic model eye based on the Hwey-Lan Liou schematic eye using the Zemax ray-tracing program. Changes in optical performance were analyzed in model eyes with 3-mm, 4-mm, and 5-mm pupil diameters and decentered from 0.25 mm to 0.75 mm with an interval of 5° at the meridian direction from 0° to 90°. The ratio of the modulation transfer function (MTF) between a decentered and a centered IOL (MTFDecentration/MTFCentration) was calculated to analyze the decrease in optical performance. Optical performance of the toric IOL remained unchanged when IOLs were decentered in any meridian direction. The MTFs of the two IOLs decreased, whereas optical performance remained equivalent after decentration. The MTFDecentration/MTFCentration ratios of the IOLs at a decentration from 0.25 mm to 0.75 mm were comparable in the toric and SN60AT IOLs. After decentration, MTF decreased further, with the MTF of the toric IOL being slightly lower than that of the SN60AT IOL. Imaging qualities of the two IOLs decreased when the pupil diameter and the degree of decentration increased, but the decrease was similar in the toric and spherical IOLs. Toric IOLs were comparable to spherical IOLs in terms of tolerance to decentration at the correct axial position.

  18. Optical performance of toric intraocular lenses in the presence of decentration

    PubMed Central

    Zhang, Bin; Ma, Jin-Xue; Liu, Dan-Yan; Du, Ying-Hua; Guo, Cong-Rong; Cui, Yue-Xian

    2015-01-01

    AIM To evaluate the optical performance of toric intraocular lenses (IOLs) after decentration and with different pupil diameters, but with the IOL astigmatic axis aligned. METHODS Optical performances of toric T5 and SN60AT spherical IOLs after decentration were tested on a theoretical pseudophakic model eye based on the Hwey-Lan Liou schematic eye using the Zemax ray-tracing program. Changes in optical performance were analyzed in model eyes with 3-mm, 4-mm, and 5-mm pupil diameters and decentered from 0.25 mm to 0.75 mm with an interval of 5° at the meridian direction from 0° to 90°. The ratio of the modulation transfer function (MTF) between a decentered and a centered IOL (MTFDecentration/MTFCentration) was calculated to analyze the decrease in optical performance. RESULTS Optical performance of the toric IOL remained unchanged when IOLs were decentered in any meridian direction. The MTFs of the two IOLs decreased, whereas optical performance remained equivalent after decentration. The MTFDecentration/MTFCentration ratios of the IOLs at a decentration from 0.25 mm to 0.75 mm were comparable in the toric and SN60AT IOLs. After decentration, MTF decreased further, with the MTF of the toric IOL being slightly lower than that of the SN60AT IOL. Imaging qualities of the two IOLs decreased when the pupil diameter and the degree of decentration increased, but the decrease was similar in the toric and spherical IOLs. CONCLUSIONS Toric IOLs were comparable to spherical IOLs in terms of tolerance to decentration at the correct axial position. PMID:26309871

  19. Ex Vivo Liver Experiment of Hydrochloric Acid-Infused and Saline-Infused Monopolar Radiofrequency Ablation: Better Outcomes in Temperature, Energy, and Coagulation.

    PubMed

    Jiang, Xiong-ying; Gu, Yang-kui; Huang, Jin-hua; Gao, Fei; Zou, Ru-hai; Zhang, Tian-qi

    2016-04-01

    To compare temperature, energy, and coagulation between hydrochloric acid-infused radiofrequency ablation (HAIRFA) and normal saline-infused radiofrequency ablation (NSIRFA) in ex vivo porcine liver model. 30 fresh porcine livers were excised in 60 lesions, 30 with HAIRFA and the other 30 with NSIRFA. Both modalities used monopolar perfusion electrode connected to a RF generator set at 103 °C and 30 W. In each group, ablation time was set at 10, 20, or 30 min (10 lesions from each group at each time). We compared tissue temperatures (at 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 cm away from the electrode tip), average power, deposited energy, deposited energy per coagulation volume (DEV), coagulation diameters, coagulative volume, and spherical ratio between the two groups. Temperature-time curves showed that HAIRFA provided progressively greater heating than that of NSIRFA. At 30 min, mean average power, deposited energy, coagulation volumes (113.67 vs. 12.28 cm(3)) and diameters, and increasing in tissue temperature were much greater with HAIRFA (P < 0.001 for all), except DEV was lower (456 vs. 1396 J/cm(3), P < 0.001). The spherical ratio was closer to 1 with HAIRFA (1.23 vs. 1.46). Coagulation diameters, volume, and average power of HAIRFA increased significantly with longer ablation times. While with NSIRFA, these characteristics were stable till later 20 min, except the power decreased with longer ablation times. HAIRFA creates much larger and more spherical lesions by increasing overall energy deposition, modulating thermal conductivity, and transferring heat during ablation.

  20. Prospective Measurement of Patient Exposure to Radiation During Pediatric Ureteroscopy

    PubMed Central

    Kokorowski, Paul J.; Chow, Jeanne S.; Strauss, Keith; Pennison, Melanie; Routh, Jonathan C.; Nelson, Caleb P.

    2013-01-01

    Objective Little data have been reported regarding radiation exposure during pediatric endourologic procedures, including ureteroscopy (URS). We sought to measure radiation exposure during pediatric URS and identify opportunities for exposure reduction. Methods We prospectively observed URS procedures as part of a quality improvement initiative. Pre-operative patient characteristics, operative factors, fluoroscopy settings and radiation exposure were recorded. Our outcomes were entrance skin dose (ESD, in mGy) and midline dose (MLD, in mGy). Specific modifiable factors were identified as targets for potential quality improvement. Results Direct observation was performed on 56 consecutive URS procedures. Mean patient age was 14.8 ± 3.8 years (range 7.4 to 19.2); 9 children were under age 12 years. Mean ESD was 46.4 ± 48 mGy. Mean MLD was 6.2 ± 5.0 mGy. The most important major determinant of radiation dose was total fluoroscopy time (mean 2.68 ± 1.8 min) followed by dose rate setting, child anterior-posterior (AP) diameter, and source to skin distance (all p<0.01). The analysis of factors affecting exposure levels found that the use of ureteral access sheaths (p=0.01) and retrograde pyelography (p=0.04) were significantly associated with fluoroscopy time. We also found that dose rate settings were higher than recommended in up to 43% of cases and ideal C-arm positioning could have reduced exposure 14% (up to 49% in some cases). Conclusions Children receive biologically significant radiation doses during URS procedures. Several modifiable factors contribute to dose and could be targeted in efforts to implement dose reduction strategies. PMID:22341275

  1. Teaching and Learning for Sustainable Development: ESD Research in Technology Education

    ERIC Educational Resources Information Center

    Pavlova, Margarita

    2013-01-01

    When education for sustainable development (ESD) emerged as part of the educational agenda in the international arena, it was associated with significant shifts in the educational debate about the purpose and nature of education and with the need to respond to crises caused by the modern idea of progress. Scientists from different fields warn…

  2. Technical Reliability Studies. EOS/ESD Technology Abstracts

    DTIC Science & Technology

    1981-01-01

    MECHANISMS MELAMINE MESFETS MICROWAVE MIS 15025 AUTOMATIC MACHINE PRECAUTIONS FOR HOS/OiOS 15006 INSTRUCTIONS FOR INSTALLATION AND...ELIMINATION OF EOS INDUCED SECONDARY FAILURE MECHANISMS 15000 USE OF MELAMINE WORK-SURFACE FOR ESD POTENTIAL BLEED OFF 16141 MICROWAVE NANOSECOND... microwave devices, optoelectronics, and selected nonelectronic parts employed in military, space and commercial applications. In addition, a System

  3. Evaluation Tool for the Application of Discovery Teaching Method in the Greek Environmental School Projects

    ERIC Educational Resources Information Center

    Kalathaki, Maria

    2015-01-01

    Greek school community emphasizes on the discovery direction of teaching methodology in the school Environmental Education (EE) in order to promote Education for the Sustainable Development (ESD). In ESD school projects the used methodology is experiential teamwork for inquiry based learning. The proposed tool checks whether and how a school…

  4. Climate Change Education and Education for Sustainable Development in the Republic of Korea: A Status Report

    ERIC Educational Resources Information Center

    Sung, Junghee

    2015-01-01

    The Republic of Korea (ROK) has officially declared its national vision of green growth, and actively develops and implements policies related to education for sustainable development (ESD), green growth education (GGE) and climate change education (CCE). Over the Decade of ESD, the ROK experienced three administrations which have taken different…

  5. Education for Sustainable Development: The Impact of an Out-Door Program on Student Teachers

    ERIC Educational Resources Information Center

    Zacharious, Aravella; Valanides, Nicos

    2006-01-01

    The study used an outdoor program for promoting Education for Sustainable Development (ESD) in primary education and investigated the extent to which primary student teachers were prepared to deal with ESD. It also investigated the impact of an outdoor program on primary student teachers' knowledge and attitudes towards sustainable issues, and on…

  6. Securing the Place of Educating for Sustainable Development within Existing Curriculum Frameworks: A Reflective Analysis

    ERIC Educational Resources Information Center

    Metz, Don; McMillan, Barbara; Maxwell, Mona; Tetrault, Amanda

    2010-01-01

    Educating for sustainable development (ESD) is generally found within existing disciplinary frameworks. In this paper, our intent is to compare the views and practices of environmental educators who pursue ESD from a perspective different from what is occurring in our own constituency. We collected data on curriculum, teaching perspectives and…

  7. Business Opportunities Guide

    DTIC Science & Technology

    1987-01-01

    Electronic Systems Division Business Opportunities Guide. We remain committed to providing industry the best information possible on pending ESD...Commander Justific ill,):, By_ D.is’ * . ’ . Dist, : :,. ELECTRONIC SYSTEMS DIVISION BUSINESS OPPORTUNITIES GUIDE The complex Command, Control...Communications (C) systems necessary for tomorrow’s Air Foice can only be developed by a stronq’ESD/industry team. Our first Business Opportunities Guide

  8. Research in Environmental Education and Education for Sustainable Development in Germany: The State of the Art

    ERIC Educational Resources Information Center

    Seybold, Hansjorg; Rieb, Werner

    2006-01-01

    This article outlines the state of the art in German research on environmental education and education for sustainable development (ESD). Empirical German research on the importance of environmental education and ESD for schools is analysed in relation to three research fields. First, survey research describes the practice of environmental…

  9. SRM propellant, friction/ESD testing

    NASA Technical Reports Server (NTRS)

    Campbell, L. A.

    1989-01-01

    Following the Pershing 2 incident in 1985 and the Peacekeeper ignition during core removal in 1987, it was found that propellant can be much more sensitive to Electrostatic Discharges (ESD) than ever before realized. As a result of the Peacekeeper motor near miss incident, a friction machine was designed and fabricated, and used to determine friction hazards during core removal. Friction testing with and electrical charge being applied across the friction plates resulted in propellant ignitions at low friction pressures and extremely low ESD levels. The objective of this test series was to determine the sensitivity of solid rocket propellant to combined friction pressure and electrostatic stimuli and to compare the sensitivity of the SRM propellant to Peacekeeper propellant. The tests are fully discussed, summarized and conclusions drawn.

  10. Environmental Sciences Division annual progress report for period ending September 30, 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1994-12-31

    This progress report summarizes the research and development activities conducted in the Environmental Sciences Division (ESD) of Oak Ridge National Laboratory during fiscal year (FY) 1994, which extended from October 1, 1993, through September 30, 1994. The report is structured to provide descriptions of current activities and accomplishments in each of the division`s major organizational units. Following the sections describing the organizational units are sections highlighting ESD Scientific, Technical, and Administrative Achievement awards and listing information necessary to covey the scope of the work in the division. An organizational chart of staff and long-term guests who wee in ESD atmore » the end of FY 1994 is located in the final section of the report.« less

  11. Effect of surface polishing and vacuum firing on electron stimulated desorption from 316LN stainless steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Malyshev, Oleg B., E-mail: oleg.malyshev@stfc.ac.uk; Hogan, Benjamin T.; Pendleton, Mark

    2014-09-01

    The reduction of thermal outgassing from stainless steel by surface polishing or vacuum firing is well-known in vacuum technology, and the consequent use of both techniques allows an even further reduction of outgassing. The aim of this study was to identify the effectiveness of surface polishing and vacuum firing for reducing electron-stimulated desorption (ESD) from 316LN stainless steel, which is a frequently used material for particle accelerator vacuum chambers and components. It was found that, unlike for thermal outgassing, surface polishing does not reduce the ESD yield and may even increase it, while vacuum firing of nonpolished sample reduces onlymore » the H{sub 2} ESD yield by a factor 2.« less

  12. Continuous electron stimulated desorption using a ZrO2/Ag permeation membrane

    NASA Technical Reports Server (NTRS)

    Outlaw, R. A.; Hoflund, Gar B.; Davidson, M. R.

    1989-01-01

    During the development of an atomic oxygen beam generator for laboratory simulation of the atmospheric conditions in low earth orbit, a new technique for performing electron stimulated desorption (ESD) in a continuous manner has been developed. In this technique, oxygen permeates through an Ag membrane at elevated temperature thereby providing a continuous supply of oxygen atoms to the 1000-A ZrO2 coating at the vacuum interface. ESD then results in a large peak of neutral O2 molecules which ultimately decay into steady-state desorption. The ESD signal is linear with respect to primary beam flux (0.035 O2 molecules per electron at a primary beam energy of 1 keV) but nonlinear with respect to primary beam energy.

  13. Necessity of angiotensin-converting enzyme-related gene for cardiac functions and longevity of Drosophila melanogaster assessed by optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Liao, Fang-Tsu; Chang, Cheng-Yi; Su, Ming-Tsan; Kuo, Wen-Chuan

    2014-01-01

    Prior studies have established the necessity of an angiotensin-converting enzyme-related (ACER) gene for heart morphogenesis of Drosophila. Nevertheless, the physiology of ACER has yet to be comprehensively understood. Herein, we employed RNA interference to down-regulate the expression of ACER in Drosophila's heart and swept source optical coherence tomography to assess whether ACER is required for cardiac functions in living adult flies. Several contractile parameters of Drosophila heart, including the heart rate (HR), end-diastolic diameter (EDD), end-systolic diameter (ESD), percent fractional shortening (%FS), and stress-induced cardiac performance, are shown, which are age dependent. These age-dependent cardiac functions declined significantly when ACER was down-regulated. Moreover, the lifespans of ACER knock-down flies were significantly shorter than those of wild-type control flies. Thus, we posit that ACER, the Drosophila ortholog of mammalian angiotensin-converting enzyme 2 (ACE2), is essential for both heart physiology and longevity of animals. Since mammalian ACE2 controls many cardiovascular physiological features and is implicated in cardiomyopathies, our findings that ACER plays conserved roles in genetically tractable animals will pave the way for uncovering the genetic pathway that controls the renin-angiotensin system.

  14. Spherical aberration yielding optimum visual performance: Evaluation of intraocular lenses using adaptive optics simulation

    PubMed Central

    Werner, John S.; Elliott, Sarah L.; Choi, Stacey S.; Doble, Nathan

    2009-01-01

    PURPOSE To evaluate the influence of spherical aberration on contrast sensitivity using adaptive optics. SETTING Vision Science and Advanced Retinal Imaging Laboratory, Department of Ophthalmology & Vision Science, University of California, Davis Medical Center, Sacramento, California, USA. METHODS Contrast sensitivity at 8 cycles per degree was evaluated using an adaptive optics system that permitted aberrations to be measured with a Shack-Hartman wavefront sensor and controlled by a 109 actuator continuous-surface deformable mirror that was at a plane conjugate to the observer’s pupil. Vertical Gabor patches were viewed through a 6.3 mm diameter pupil conjugate aperture. Contrast sensitivity was measured with the deformable mirror set to produce 1 of 5 spherical aberration profiles (−0.2 to +0.2 μm). Contrast sensitivity over the range of spherical aberration was fitted with a polynomial function. RESULTS Three observers (age 21 to 24 years) participated. The measured total mean spherical aberration resulting from the spherical aberration profiles produced by the deformable mirror was between −0.15 μm and +0.25 μm. The peak contrast sensitivity of this function for the 3 observers combined occurred at +0.06 μm of spherical aberration. The peak contrast sensitivity was also achieved with positive spherical aberration for observer (mean 0.09). CONCLUSION There was intersubject variability in the measurements; however, the average visual performance was best with the introduction of a small positive spherical aberration. PMID:19545813

  15. Single microparticle launching method using two-stage light-gas gun for simulating hypervelocity impacts of micrometeoroids and space debris.

    PubMed

    Kawai, Nobuaki; Tsurui, Kenji; Hasegawa, Sunao; Sato, Eiichi

    2010-11-01

    A single microparticle launching method is described to simulate the hypervelocity impacts of micrometeoroids and microdebris on space structures at the Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency. A microparticle placed in a sabot with slits is accelerated using a rifled two-stage light-gas gun. The centrifugal force provided by the rifling in the launch tube separates the sabot. The sabot-separation distance and the impact-point deviation are strongly affected by the combination of the sabot diameter and the bore diameter, and by the projectile diameter. Using this method, spherical projectiles of 1.0-0.1 mm diameter were launched at up to 7 km/s.

  16. Single microparticle launching method using two-stage light-gas gun for simulating hypervelocity impacts of micrometeoroids and space debris

    NASA Astrophysics Data System (ADS)

    Kawai, Nobuaki; Tsurui, Kenji; Hasegawa, Sunao; Sato, Eiichi

    2010-11-01

    A single microparticle launching method is described to simulate the hypervelocity impacts of micrometeoroids and microdebris on space structures at the Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency. A microparticle placed in a sabot with slits is accelerated using a rifled two-stage light-gas gun. The centrifugal force provided by the rifling in the launch tube separates the sabot. The sabot-separation distance and the impact-point deviation are strongly affected by the combination of the sabot diameter and the bore diameter, and by the projectile diameter. Using this method, spherical projectiles of 1.0-0.1 mm diameter were launched at up to 7 km/s.

  17. SURFACE CHEMICAL EFFECTS ON COLLOID STABILITY AND TRANSPORT THROUGH NATURAL POROUS MEDIA

    EPA Science Inventory

    Surface chemical effects on colloidal stability and transport through porous media were investigated using laboratory column techniques. Approximately 100 nm diameter, spherical, iron oxide particles were synthesized as the mobile colloidal phase. The column packing material was ...

  18. [Comparison on Oral versus Intravenous Proton Pump Inhibitors for Prevention of Bleeding after Endoscopic Submucosal Dissection of Gastric Lesions].

    PubMed

    Jung, Yeoun Su; Kim, Kyeong Ok; Lee, Si Hyung; Jang, Byung Ik; Kim, Tae Nyeun

    2016-02-01

    Although intravenous proton pump inhibitor (PPI) has been used for the prevention of post endoscopic submucosal dissection (ESD) bleeding, the route of administration has not been confirmed. The aim of the present study was to compare the efficacy of intravenous and oral PPI administration for the prevention of delayed post ESD bleeding. Total 166 consecutive patients were randomly assigned to 30 mg lansoprazol twice a day (PO group) and 120 mg pantoprazole intravenous injection (IV group) for 48 hours. Finally, 65 patients in PO group and 87 patients in IV group were analyzed. After ESD, all patients underwent follow up endoscopy after 24 hours and were observed the symptoms of bleeding up to 60 days after ESD. Age, sex and use of anticoagulants were not different between groups. At follow up endoscopy after 24 hours, oozing and exposed vessel was noted in 4.6% of PO group and 8.0% of IV group and there was no significant difference. Delayed bleeding occurred in 4 of 65 patients (6.2%) in the PO group and 8 of 87 patients (9.2%) in the IV group (p>0.999). By multivariate analysis, oozing or exposed vessels at follow up endoscopy were risk factors for delayed bleeding (OR=17.5, p=0.022). There was no significant difference in the delayed bleeding, length of hospital stay according to the administration route. Bleeding stigmata at follow up endoscopy was risk factor of delayed bleeding. Oral PPI administration can cost-effectively replace IV PPI for prevention of post ESD bleeding.

  19. Animal feasibility study of an innovated splash-needle for endoscopic submucosal dissection in the upper gastrointestinal tract.

    PubMed

    Fujishiro, Mitsuhiro; Sugita, Noriyuki

    2013-01-01

    The high frequency of complications accompanying endoscopic submucosal dissection (ESD) and its complex processes suggest that the process requires improvement. The objective of the present study was to investigate the feasibility of an innovated splash-needle for ESD. An animal feasibility study with a living pig was conducted. Six resections per portion (esophagus and upper, middle, and lower thirds of the stomach) in a total of 24 resections were carried out by using an original splash-needle or an innovated splash-needle. Major innovations were a thicker part in the middle of the knife and a metal plate on the tip of the sheath to obtain more coagulation ability. Injection solution in the submucosal layer was also changed due to possible influence on the outcomes. Main outcome measurements were entire procedure time, cutting speed, and frequency of bleeding during ESD. All the 24 resections were completed without complications. Among the obtained data, only mean cutting speeds were significantly influenced by location of the simulated lesion, which revealed that ESD at the upper third was significantly quicker than that at the lower third (P = 0.01), and ESD at the esophagus was significantly slower than that at the three parts of the stomach (P < 0.01). There was no significant difference between the different knives in each variable. The innovated splash-needle will be feasible for human use, although the safety and advantages in clinical settings must be elucidated by proper comparative studies with existing knives in humans. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.

  20. Recycle dynamics during centrifugal compressor ESD, start-up and surge control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Botros, K.K.; Jones, B.J.; Richards, D.J.

    1996-12-31

    Recycle systems are important components in the operation of centrifugal compressor stations. They are essential during a start-up operation, for surge protection and for emergency shutdown (ESD). These operations are inherently dynamic where interactions between equipment, control and gas flow occur in a complex manner with the associated risk of compressor surge. Of particular importance are the effects or recycle system capacity, the recycle valve characteristics, check valve dynamic behavior, piping geometry and capacitance around the compressor unit, and the performance characteristics of the centrifugal compressor itself. This paper presents numerical results of the effects of some of these parametersmore » on surge control, ESD and unit startup. These parameters are: (1) The effects of damping the surge control flow signal in an attempt to suppress the signal noise, on the integrity of the surge control system; (2) The effects of recycle valve characteristics, stroke time and valve capacity on ESD; (3) The effects of recycle line size on ESD; and (4) The effects of the recycle valve closing time (or rate) on the startup operation, with the intent of shortening this time to minimum for environmental reasons. Results were obtained from the solution of the pertinent dynamic equations describing the gas and equipment dynamics which has been verified against field and laboratory measurements. The samples presented in this paper were applied to a 24 MW natural gas compressor station on the NOVA Gas Transmission system, and to a scale-down laboratory model. Influence of other parameters from this investigation were published elsewhere and are cited in the reference section.« less

  1. Feasibility of electrospray deposition for rapid screening of the cocrystal formation and single step, continuous production of pharmaceutical nanococrystals.

    PubMed

    Emami, Shahram; Siahi-Shadbad, Mohammadreza; Barzegar-Jalali, Mohammad; Adibkia, Khosro

    2018-06-01

    This study employed electrospray deposition (ESD) for simultaneous synthesis and particle engineering of cocrystals. Exploring new methods for the efficient production of cocrystals with desired particle properties is an essential demand. The possibility of cocrystal formation by ESD was examined for indomethacin-saccharin, indomethacin-nicotinamide, naproxen-nicotinamide, and naproxen-iso-nicotinamide cocrystals. Solutions of the drug and coformer at stoichiometric ratios were sprayed to a high electric field which caused rapid evaporation of the solvent and the formation of fine particles. The phase purity, size, and morphology of products were compared with reference cocrystals. Experiments were performed to evaluate the effects of stoichiometric ratio, concentration and solvent type on the cocrystal formation. Physical stability and dissolution properties of the electrosprayed cocrystals were also compared with reference cocrystals. ESD was found to be an efficient and rapid method to produce cocrystals for all studied systems other than indomethacin-nicotinamide. Pure cocrystals only formed at a specific drug:coformer ratio. The solvent type has a weak effect on the cocrystal formation and morphology. Electrosprayed cocrystals exhibited nano to micrometer sizes with distinct morphologies with comparable physical stability with reference cocrystals. Nanococrystals of indomethacin-saccharin with a mean size of 219 nm displayed a threefold higher dissolution rate than solvent evaporated cocrystal. ESD successfully was utilized to produce pure cocrystals of poorly soluble drugs with different morphologies and sizes ranging from nano to micrometer sizes in one step. This study highlighted the usefulness of ESD for simultaneous preparation and particle engineering of pharmaceutical cocrystals.

  2. Investigation of the Entrance Surface Dose and Dose to Different Organs in Lumbar Spine Imaging

    PubMed Central

    Sina, S; Zeinali, B; Karimipoorfard, M; Lotfalizadeh, F; Sadeghi, M; Zamani, E; Faghihi, R

    2014-01-01

    Background: Dose assessment using proper dosimeters is especially important in radiation protection optimization and imaging justification in diagnostic radiology. Objective: The aim of this study is to obtain the Entrance Skin Dose (ESD) of patients undergoing lumbar spine imaging using two thermoluminescence dosimeters TLD-100 (LiF: Mg, Ti) and GR-200 (LiF: Mg, Cu, P) and also to obtain the absorbed dose to different organs in lumbar spine imaging with several views. Methods: To measure the ESD values of the patients undergoing lumbar spine imaging, the two TLD types were put on their skin surface. The ESD values for different views of lumbar spine imaging were also measured by putting the TLDs at the surface of the Rando phantom. Several TLD chips were inserted inside different organs of Rando phantom to measure the absorbed dose to different organs in lumbar spine imaging. Results: The results indicate that there is a close agreement between the results of the two dosimeters. Based on the results of this experiment, the ESD dose of the 16 patients included in this study varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for GR-200 measurements. The ESDs obtained by putting the two types of TLDs at the surface of Rando phantom are in close agreement. Conclusion: According to the results, the GR200 has greater sensitivity than the TLD-100. PMID:25599058

  3. Extended evaluation on the ES-D3 cell differentiation assay combined with the BeWo transport model, to predict relative developmental toxicity of triazole compounds.

    PubMed

    Li, Hequn; Flick, Burkhard; Rietjens, Ivonne M C M; Louisse, Jochem; Schneider, Steffen; van Ravenzwaay, Bennard

    2016-05-01

    The mouse embryonic stem D3 (ES-D3) cell differentiation assay is based on the morphometric measurement of cardiomyocyte differentiation and is a promising tool to detect developmental toxicity of compounds. The BeWo transport model, consisting of BeWo b30 cells grown on transwell inserts and mimicking the placental barrier, is useful to determine relative placental transport velocities of compounds. We have previously demonstrated the usefulness of the ES-D3 cell differentiation assay in combination with the in vitro BeWo transport model to predict the relative in vivo developmental toxicity potencies of a set of reference azole compounds. To further evaluate this combined in vitro toxicokinetic and toxicodynamic approach, we combined ES-D3 cell differentiation data of six novel triazoles with relative transport rates obtained from the BeWo model and compared the obtained ranking to the developmental toxicity ranking as derived from in vivo data. The data show that the combined in vitro approach provided a correct prediction for in vivo developmental toxicity, whereas the ES-D3 cell differentiation assay as stand-alone did not. In conclusion, we have validated the combined in vitro approach for developmental toxicity, which we have previously developed with a set of reference azoles, for a set of six novel triazoles. We suggest that this combined model, which takes both toxicodynamic and toxicokinetic aspects into account, should be further validated for other chemical classes of developmental toxicants.

  4. Quantitative evaluation of the safety of mucosal incision and submucosal dissection for colon during endoscopic submucosal dissection using carbon dioxide laser

    NASA Astrophysics Data System (ADS)

    Noguchi, Takuma; Honda, Norihiro; Hazama, Hisanao; Morita, Yoshinori; Awazu, Kunio

    2018-02-01

    Since the increase in the overall mortality rate in patients with colon cancer is remarkably high in recent years, early treatment is required. For this reason, endoscopic submucosal dissection (ESD) has been at the forefront of international attention as a low invasive treatment for early digestive cancer. In current ESD procedure, an electrosurgical knife is used for mucosal incision and subsequent submucosal dissection. However, the perforation has been reported to occur by approximately 5%. Thus, to enhance the tissue selectivity of this modality, we focused on the application of laser for ESD. A carbon dioxide laser was chosen as a surgical knife because the saline or a sodium hyaluronate solution injected into the submucosal layer in current ESD procedure has a high absorption coefficient at the wavelength of the carbon dioxide laser. In this research, ex vivo experiment was performed at the output power of 3-7 W and discuss the optimum irradiation power of laser. As a result of ex vivo experiment using extracted porcine colon tissues, mucosal incision and submucosal dissection were safely and less invasively performed in every output power, without reaching the thermal damage to a muscular layer. This is because a carbon dioxide laser is strongly absorbed by saline injected into submucosa. ESD using a carbon dioxide laser is a safer method for the treatment of early colon cancer. We are planning to measure and compare the optical and thermal properties of porcine colon with those of human colon.

  5. Education for Sustainable Development in Higher Education: State-of-the-Art, Barriers and Challenges

    ERIC Educational Resources Information Center

    Fernández-Sánchez, Gonzalo; Bernaldo, María Olga; Castillejo, Ana; Manzanero, Ana María

    2014-01-01

    Education for Sustainable Development (ESD) is a new educational paradigm that allows Universities to lead and respond to social needs towards a more sustainable life. The ESD is a global preparedness and complex phenomena in relation to the effects of human activity on the environment, society and economy in spatial (global, regional and local)…

  6. The European Virtual Seminar on Sustainable Development as an Opportunity for Staff ESD Competence Development within University Curricula

    ERIC Educational Resources Information Center

    de Kraker, Joop; Dlouhá, Jana; Machackova Henderson, Laura; Kapitulcinová, Dana

    2017-01-01

    Purpose: The purpose of this paper is to assess the current and potential value of the European Virtual Seminar on Sustainable Development (EVS) as an opportunity for professional development in Education for Sustainable Development (ESD) for teaching staff at university level. Design/methodology/approach: The paper presents and reflects on the…

  7. Personality, Moral Purpose, and the Leadership of an Education for Sustainable Development

    ERIC Educational Resources Information Center

    Bottery, Mike; Wright, Nigel; James, Sarah

    2012-01-01

    This paper describes how two primary head teachers, nationally recognised as role models for the development of an education for sustainable development (ESD) in their schools, manage the implementation of this area. In doing so, it shows how they adopt two very different approaches to ESD and to their job generally, and suggests that whilst there…

  8. Starting the Pluralistic Tradition of Teaching? Effects of Education for Sustainable Development (ESD) on Pre-Service Teachers' Views on Teaching about Sustainable Development

    ERIC Educational Resources Information Center

    Andersson, Klas

    2017-01-01

    There is currently a well-established belief among politicians, scholars and university representatives that educational systems can produce positive attitudes towards sustainable development (SD) among citizens. This article investigates whether Education for Sustainable Development (ESD) in teacher education has effects on pre-service teachers'…

  9. Education for Sustainable Development and Normativity: A Transactional Analysis of Moral Meaning-Making and Companion Meanings in Classroom Communication

    ERIC Educational Resources Information Center

    Ostman, Leif

    2010-01-01

    The purpose of the present article is to present and illustrate two different ways of analysing the normativity and discursivity of classroom communication during education for sustainable development (ESD). The two types of analysis can provide important knowledge for discussions of ESD in relation to morals and democracy. Both methods are based…

  10. Analysing Key Debates in Education and Sustainable Development in Relation to ESD Practice in Viet Nam

    ERIC Educational Resources Information Center

    Balls, Emily

    2016-01-01

    This article is based on qualitative field research carried out in Ha Noi, Viet Nam, in 2013 for an MA dissertation in Education and International Development at the UCL Institute of Education. It analyses interpretations of education for sustainable development (ESD) in Viet Nam, relating these to key debates around instrumental and democratic…

  11. Embedding Education for Sustainable Development in Higher Education: A Case Study Examining Common Challenges and Opportunities for Undergraduate Programmes

    ERIC Educational Resources Information Center

    Jones, Paula; Trier, Colin J.; Richards, Jonathan P.

    2008-01-01

    This paper explores the perceptions of academics and students towards embedding Education for Sustainable Development (ESD) into undergraduate degree programmes in the School for Earth, Ocean and Environmental Science (SEOES) at the University of Plymouth. The main purpose of the research was to identify current ESD related teaching and learning…

  12. Learning for and about Sustainability in Higher Education--A Regional Perspective Based on Experiences from the Baltic and the Mediterranean

    ERIC Educational Resources Information Center

    Scoullos, Michael; Malotidi, Vicky; Lindroos, Paula; Suomalainen, Sinikka

    2017-01-01

    Purpose: The purpose of the paper is to present and compare collective efforts of higher education institutions working through regional networks in introducing and promoting education for sustainable development (ESD) and environmental education (EE) in two most significant EU boarder regions. Efforts to support EE/ESD in higher education are…

  13. Techniques for Teaching Standard English Composition to English as a Second Dialect Students.

    ERIC Educational Resources Information Center

    Edwards, Thomas O.

    English as a second dialect (ESD) students are those who have developed linguistic patterns from their parents and other members of their cultural milieu. Since the ESD students seldom find themselves in a setting that demands the use of standard English, they come to higher education with a well developed linguistic pattern that is alien to…

  14. Education for Sustainable Development: Assessment of the Current Situation at the Faculty of Engineering of Notre Dame University--Louaize

    ERIC Educational Resources Information Center

    Salem, Talal; Harb, Jacques

    2012-01-01

    There is a growing need to incorporate educational sustainable development (ESD) principles into engineering education. This paper identifies engineering competencies within the Faculty of Engineering at Notre Dame University--Louaize and the means to shift towards sustainability. ESD tools are used to carry the analysis, keeping in mind the…

  15. Challenging the Concept of Ethical Literacy within Education for Sustainable Development (ESD): Storytelling as a Method within Sustainability Didactics

    ERIC Educational Resources Information Center

    Franck, Olof; Osbeck, Christina

    2018-01-01

    Ethical literacy seems to be used, within Education for Sustainable Development (ESD), in various ways, some more general and others morally specific, emphasising individuals' responsibility. The overarching aim of this paper is to present some prerequisites for the development of narrative methods that focus on the vision of a good society…

  16. Branding the Green Education: Challenges Facing Implementation of Education for Sustainable Development in Egypt

    ERIC Educational Resources Information Center

    Ramzy, Omar; Wahieb, Rasha

    2012-01-01

    Due to the scarcity in natural resources and the demand for green labour and economy, education for sustainable development (ESD) gained a great importance in developed countries, let alone developing ones. From this point of view, this paper is studying the possibility of infusing ESD in Egypt after one and a half years since January 2011 youth…

  17. Biogeochemical Cycles for Combining Chemical Knowledge and ESD Issues in Greek Secondary Schools Part II: Assessing the Impact of the Intervention

    ERIC Educational Resources Information Center

    Koutalidi, Sophia; Psallidas, Vassilis; Scoullos, Michael

    2016-01-01

    In searching for effective ways to combine science/chemical education with EE/ESD, new didactic materials were designed and produced focussing on biogeochemical cycles and their connection to sustainable development. The materials were experimentally applied in 16 Greek schools under the newly introduced compulsory "school project" which…

  18. How Education for Sustainable Development Is Implemented in Germany: Looking through the Lens of Educational Governance Theory

    ERIC Educational Resources Information Center

    Bormann, Inka; Nikel, Jutta

    2017-01-01

    The United Nations (UN) Decade of Education for Sustainable Development (ESD) aimed to integrate the principles, values and practices of sustainable development into all aspects of education and learning around the world. The authors of this article address the implementation process of ESD in Germany during the UN Decade (2005-2014). By…

  19. Learning for a Change: Exploring the Relationship between Education and Sustainable Development

    ERIC Educational Resources Information Center

    Vare, Paul; Scott, William

    2007-01-01

    Whether we view sustainable development as our greatest challenge or a subversive litany, every phase of education is now being urged to declare its support for education for sustainable development (ESD). In this paper, we explore the ideas behind ESD and, building on work by Foster and by Scott and Gough, we argue that it is necessary now to…

  20. Current status of colonic endoscopic mucosal resection in the west and the interface with endoscopic submucosal dissection.

    PubMed

    Bourke, Michael

    2009-07-01

    Endoscopic Mucosal Resection (EMR) is now widely practised by western endoscopists to treat large sessile colonic polyps or laterally spreading tumours. Despite its widespread application, the technique of colonic EMR is not standardised. A lesion specific endoscopic treatment approach is also lacking. For lesions larger than 25mm, EMR is limited by its inability to achieve en-bloc resection. En-bloc resection has many theoretical advantages including more accurate histological assessment, reduced recurrence and potentially curative treatment for low risk submucosal invasive neoplasia particularly in patients with significant co-morbidity. Hence, Japanese endoscopists, having pioneered endoscopic submucosal dissection (ESD) in the upper gastrointestinal tract for the en-bloc resection of superficial neoplasia, now advocate the use of ESD for laterally spreading tumours of the colon greater than 25-30mm. This treatment strategy is not widely accepted or practised in the west and has its own inherent problems. The absence of suitable gastric lesions on which to develop ESD skills is also another significant barrier to the development of colonic ESD. It is also possible that modification and refinement in EMR technique may increase the size limit for colonic EMR.

  1. Endoscopic Submucosal Dissection of Gastric Epithelial Neoplasms after Partial Gastrectomy: A Single-Center Experience

    PubMed Central

    Song, Byeong Gu; Lee, Bong Eun; Jeon, Hye Kyung; Baek, Dong Hoon; Song, Geun Am

    2017-01-01

    Aims To investigate the feasibility and safety of endoscopic submucosal dissection (ESD) of gastric epithelial neoplasms in the remnant stomach (GEN-RS) after various types of partial gastrectomy. Methods This study included 29 patients (31 lesions) who underwent ESD for GEN-RS between March 2006 and August 2016. Clinicopathologic data were retrieved retrospectively to assess the therapeutic ESD outcomes, including en bloc and complete resection rates and procedure-related adverse events. Results The en bloc, complete, and curative resection rates were 90%, 77%, and 71%, respectively. The types of previous gastrectomy, tumor size, macroscopic type, and tumor histology were not associated with incomplete resection. Only tumors involving the suture lines from the prior partial gastrectomy were significantly associated with incomplete resection. The procedure-related bleeding and perforation rates were 6% and 3%, respectively; none of the adverse events required surgical intervention. During a median follow-up period of 25 months (range, 6–58 months), there was no recurrence in any case. Conclusions ESD is a safe and feasible treatment for GEN-RS regardless of the previous gastrectomy type. However, the complete resection rate decreases for lesions involving the suture lines. PMID:28592968

  2. KSC Electrostatic Discharge (ESD) Issues

    NASA Technical Reports Server (NTRS)

    Buhler, Charles

    2008-01-01

    Discussion of key electrostatic issues that have arisen during the past few years at KSC that the Electrostatics Laboratory has studied. The lab has studied in depth the Space Shuttle's Thermal Control System Blankets, the International Space Station Thermal Blanket, the Pan/Tilt Camera Blankets, the Kapton Purge Barrier Curtain, the Aclar Purge Barrier Curtain, the Thrust Vector Controller Blankets, the Tyvek Reaction Control System covers, the AID-PAK and FLU-9 pyro inflatable devices, the Velostat Solid Rocket Booster mats, and the SCAPE suits. In many cases these materials are insulating meaning that they might be a source of unsafe levels of electrostatic discharge (ESD). For each, the lab provided in-depth testing of each material within its current configuration to ensure that it does not cause an ESD concern that may violate the safety of the astronauts, the workers and equipment for NASA. For example the lab provides unique solutions and testing such as Spark Incendivity Testing that checks whether a material is capable of generating a spark strong enough to ignite a flammable gas. The lab makes recommendations to changes in specifications, procedures, and material if necessary. The lab also consults with a variety of non-safety related ESD issues for the agency.

  3. [A Case of Combined Treatment Approach of Endoscopic Submucosal Dissection and Transanal Minimally Invasive Surgery for Radiation Induced Rectal Cancer].

    PubMed

    Miyake, Toru; Sonoda, Hiromichi; Shimizu, Tomoharu; Ueki, Tomoyuki; Mori, Haruki; Takebayashi, Katsushi; Kaida, Sachiko; Yamaguchi, Tsuyoshi; Iida, Hiroya; Ban, Hiromitsu; Tani, Masaji

    2018-04-01

    It is hard to determine treatment strategy for radiation induced carcinoma, because radiation cause fibrosis to adjacent organ.The patient was in the 70's, who underwent 70 Gy radiation therapy for prostate cancer 5 years ago.He visited hospital because of fecal occult blood.Endoscopic examination revealed laterally spreading tumor(LST)in rectal front wall, and he referred to our hospital in purpose of endoscopic submucosal dissection(ESD).We performed ESD for LST, following transanal minimally invasive surgery to suture mucosal defect.He discharged out hospital 9 days after operation without any adverse event except anal pain.Suturing of mucosal defect after ESD might be potent to prevent postoperative complications in radiation induced rectal cancer.

  4. From environment to sustainable development: China's strategies for ESD in basic education

    NASA Astrophysics Data System (ADS)

    Zhang, Tiedao

    2010-06-01

    This paper intends to provide an overview of the reorientation of education in China in the period 1998-2009 with regard to development issues. During this time, the focus has shifted gradually from the environment and health to education for sustainable development. The article centres on highlighting the main interventions and strategies adopted by China's schools to make this reorientation possible, including: the introduction of new visions of sustainable development and project planning; the establishment of organisational mechanisms and capacity-building measures for their implementation in the field; the integration of ESD into teaching and learning processes; the maintenance of an action-research mechanism for innovations; and the sharing of lessons with both the national and the international community in order to make the implementation of ESD more effective.

  5. Spatial filters for high-peak-power multistage laser amplifiers.

    PubMed

    Potemkin, A K; Barmashova, T V; Kirsanov, A V; Martyanov, M A; Khazanov, E A; Shaykin, A A

    2007-07-10

    We describe spatial filters used in a Nd:glass laser with an output pulse energy up to 300 J and a pulse duration of 1 ns. This laser is designed for pumping of a chirped-pulse optical parametric amplifier. We present data required to choose the shape and diameter of a spatial filter lens, taking into account aberrations caused by spherical surfaces. Calculation of the optimal pinhole diameter is presented. Design features of the spatial filters and the procedure of their alignment are discussed in detail.

  6. Fabrication and characterization of millimeter-scale translucent La{sub 2}O{sub 3}-doped Al{sub 2}O{sub 3} ceramic hollow spheres

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Haoting; Liao, Qilong, E-mail: liaoqilong@swust.edu.cn; Dai, Yunya

    2016-04-15

    Highlights: • Millimeter-scale translucent La{sub 2}O{sub 3}-doped Al{sub 2}O{sub 3} hollow spheres have been prepared. • The diameters of the prepared hollow spheres are 500–1300μm. • The degree of sphericity for the prepared hollow spheres is above 98%. • The mechanisms of transparency are discussed. - Abstract: Millimeter-scale translucent La{sub 2}O{sub 3}-doped Al{sub 2}O{sub 3} ceramic hollow spheres have been successfully prepared using the oil-in-water (paraffin-in-alumina sol) droplets as precursors made by self-made T-shape micro-emulsion device. The main crystalline phase of the obtained hollow sphere is alpha alumina. The prepared translucent La{sub 2}O{sub 3}-containing Al{sub 2}O{sub 3} ceramic hollow spheresmore » have diameters of 500–1300 μm, wall thickness of about 23 μm and the degree of sphericity of above 98%. With the increase of the La{sub 2}O{sub 3} content, grains and grain-boundaries of the alumina spherical shell for the prepared millimeter-scale hollow spheres become regular and clear gradually. When the La{sub 2}O{sub 3} content is 0.1 wt.%, the crystal surface of the obtained Al{sub 2}O{sub 3} spherical shell shows optimal grains and few pores, and its transmittance reaches 42% at 532 nm laser light. This method provides a promising technique of preparing millimeter-scale translucent ceramic hollow spheres for laser inertial confined fusion.« less

  7. Experimental Study of Unsupported Nonane fuel Droplet Combustion in Microgravity

    NASA Technical Reports Server (NTRS)

    Callahan, B. J.; Avedisian, C. T.; Hertzog, D. E.; Berkery, J. W.

    1999-01-01

    Soot formation in droplet flames is the basic component of the particulate emission process that occurs in spray combustion. The complexity of soot formation motivates a one-dimensional transport condition which has obvious advantages in modeling. Recent models of spherically symmetric droplet combustion have made this assumption when incorporating such aspects as detailed chemistry and radiation. Interestingly, spherical symmetry does not necessarily restrict the results because it has been observed that the properties of carbon formed in flames are not strongly affected by the nature of the fuel or flaming configuration. What is affected, however, are the forces acting on the soot aggregates and where they are trapped by a balance of drag and thermophoretic forces. The distribution of these forces depends on the transport conditions of the flame. Prior studies of spherical droplet flames have examined the droplet burning history of alkanes, alcohols and aromatics. Data are typically the evolution of droplet, flame, extinction, and soot shell diameters. These data are only now just beginning to find their way into comprehensive numerical models of droplet combustion to test proposed oxidation schemes for fuels such as methanol and heptane. In the present study, we report new measurements on the burning history of unsupported nonane droplets in a convection-free environment to promote spherical symmetry. The far-field gas is atmospheric pressure air at room temperature. The evolution of droplet diameter was measured using high speed cine photography of a spark-ignited, droplet within a confined volume in a drop tower. The initial droplet diameters varied between 0.5 mm and 0.6 mm. The challenge of unsupported droplets is to form, deploy and ignite them with minimal disturbance, and then to keep them in the camera field of view. Because of the difficulty of this undertaking, more sophisticated diagnostics for studying soot than photographic were not used. Supporting the test droplet by a fiber fixes the droplet position but the fiber can perturb the burning process especially for a sooting fuel. Prior studies on heptane showed little evidence for soot formation due to g-droplets of similar size the relationship between sooting and droplet diameter. For nonane droplets we expect increased sooting due to the greater number of carbon atoms. As a sooting droplet burns and its diameter decreases, proportionally less soot should form. This reduced soot, as well as the influence of soot formed earlier in the burning process which collects in a 'shell', on heat transport to the flame offers the potential for a time-varying burning rate. Such an effect was investigated and revealed in results reported here. Speculation is offered for the cause of this effect and its possible relation to soot formation.

  8. Ex Vivo Liver Experiment of Hydrochloric Acid-Infused and Saline-Infused Monopolar Radiofrequency Ablation: Better Outcomes in Temperature, Energy, and Coagulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, Xiong-ying; Gu, Yang-kui; Huang, Jin-hua, E-mail: huangjh@sysucc.org.cn

    ObjectiveTo compare temperature, energy, and coagulation between hydrochloric acid-infused radiofrequency ablation (HAIRFA) and normal saline-infused radiofrequency ablation (NSIRFA) in ex vivo porcine liver model.Materials and Methods30 fresh porcine livers were excised in 60 lesions, 30 with HAIRFA and the other 30 with NSIRFA. Both modalities used monopolar perfusion electrode connected to a RF generator set at 103 °C and 30 W. In each group, ablation time was set at 10, 20, or 30 min (10 lesions from each group at each time). We compared tissue temperatures (at 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 cm away from the electrode tip), average power, deposited energy,more » deposited energy per coagulation volume (DEV), coagulation diameters, coagulative volume, and spherical ratio between the two groups.ResultsTemperature–time curves showed that HAIRFA provided progressively greater heating than that of NSIRFA. At 30 min, mean average power, deposited energy, coagulation volumes (113.67 vs. 12.28 cm{sup 3}) and diameters, and increasing in tissue temperature were much greater with HAIRFA (P < 0.001 for all), except DEV was lower (456 vs. 1396 J/cm{sup 3}, P < 0.001). The spherical ratio was closer to 1 with HAIRFA (1.23 vs. 1.46). Coagulation diameters, volume, and average power of HAIRFA increased significantly with longer ablation times. While with NSIRFA, these characteristics were stable till later 20 min, except the power decreased with longer ablation times.ConclusionsHAIRFA creates much larger and more spherical lesions by increasing overall energy deposition, modulating thermal conductivity, and transferring heat during ablation.« less

  9. Electrostatic Discharge Training Manual

    DTIC Science & Technology

    1980-09-01

    CAN BE MOLDED INTO FORMED SHAPES. FIBERBOARD, MELAMINE LAMINATES AND OTHER MATERIALS (LAMINATED OR HOMOGENEOUS) CAN BE CONSTRUCTED INTO BOXES AND...COVERED WITH, ESD PROTECTIVE MATERIALS SUCH AS METAL, MIL-B-81705 TYPE II, MIL-P- 82646 (REFERENCES 17, 16), MELAMINE LAMINATES OR OTHER ESD PROTECTIVE...CONDUCTANCE IN AVALANCHE MICROWAVE OSCILLATORS", IEEE TRANSACTIONS ON ELECTRON DEVICES, ED-i5, JUNE 1968. 32. HOLM, R., ELECTRIC CONTACTS HANDBOOK, BERLIN

  10. Education for Sustainable Development in the UK: Making the Connections between the Environment and Development Agendas

    ERIC Educational Resources Information Center

    Bourn, Douglas

    2008-01-01

    Education for Sustainable Development (ESD) is an initiative that dates back to the early 1990s. Whilst policy statements at this time referred to ESD as a bringing together of environmental and development education, in the UK, as in most other industrialized countries, it has been the environmental agenda that has tended to dominate. In the UK,…

  11. What Kind of Actions Are Appropriate? Eco-School Teachers' and Instructors' Ranking of Sustainability-Promoting Actions as Content in Education for Sustainable Development (ESD)

    ERIC Educational Resources Information Center

    Stagell, Ulrica; Almers, Ellen; Askerlund, Per; Apelqvist, Magnus

    2014-01-01

    Based on the consideration that learning about different action alternatives and strategies are essential parts of ESD, this quantitative study focuses Eco-School teachers' and instructors' views on including different sustainability-promoting actions in teaching practices. Direct actions, and actions that take place in the private sphere were…

  12. UN Global Action Programme and Education for Sustainable Development: A Critical Appraisal of the Evidence Base

    ERIC Educational Resources Information Center

    Fischer, Daniel; Aubrecht, Elisabeth Lena; Brück, Maria; Ditges, Laura; Gathen, Lea; Jahns, Maximilian; Petersmann, Moritz; Rau, Jörn; Wellmann, Christiane

    2015-01-01

    The United Nations (UN) proclaimed the years 2005 to 2014 the World Decade on Education for Sustainable Development (ESD). As a follow up on the World Decade, the UN launched a Global Action Programme (GAP) that is designed to set the framework for international activities on ESD. The GAP focuses on five priority areas that are of high relevance…

  13. New endoscopic platform for endoluminal en bloc tissue resection in the gastrointestinal tract (with videos).

    PubMed

    Kantsevoy, Sergey V; Bitner, Marianne; Piskun, Gregory

    2016-07-01

    Endoscopic removal of gastrointestinal tract lesions is increasingly popular around the world. We evaluated feasibility, safety, effectiveness, and user learning curve of new endoscopic platform for complex intraluminal interventions. A novel system, consisting of expandable working chamber with two independent instrument guides (LIG), was inserted into colon. Simulated colonic lesions were removed with endoscopic submucosal (ESD) and submuscular (ESmD) dissection. In all nine in vivo models, an intraluminal chamber and its dynamic tissue retractors (via LIG) provided a stable working space with excellent visualization and adequate access to target tissue. Endoscopic platform facilitated successful completion of 11 en bloc ESDs (mean size 43.0 ± 11.3 mm, mean time 46.3 ± 41.2 min) and eight ESmD (mean size 50.0 ± 14.1 mm, mean time 48.0 ± 21.2 min). The learning curve for ESD using this platform demonstrated three phases: rapid improvement in procedural skills took place during the first three procedures (mean ESD time 98.7 ± 40.0 min). A plateau phase then occurred (procedures 4-7) with mean procedure time 42.0 ± 13.4 min (p = 0.04), followed by another sharp improvement in procedural skills (procedures 8-11) requiring only 16.3 ± 11.4 min (p = 0.03) to complete ESD. Especially dramatic (p = 0.002) was the time difference between the first three procedures (mean time 98.7 ± 40.0 min) and subsequent eight procedures (mean time 29.1 ± 17.9 min). A newly developed endoscopic platform provides stable intraluminal working space, dynamic tissue retraction, and instrument triangulation, improving visualization and access to the target tissue for safer and more effective en bloc endoscopic submucosal and submuscular dissection. The learning curve for ESD was markedly facilitated by this new endoscopic platform.

  14. Four-mirror extreme ultraviolet (EUV) lithography projection system

    DOEpatents

    Cohen, Simon J; Jeong, Hwan J; Shafer, David R

    2000-01-01

    The invention is directed to a four-mirror catoptric projection system for extreme ultraviolet (EUV) lithography to transfer a pattern from a reflective reticle to a wafer substrate. In order along the light path followed by light from the reticle to the wafer substrate, the system includes a dominantly hyperbolic convex mirror, a dominantly elliptical concave mirror, spherical convex mirror, and spherical concave mirror. The reticle and wafer substrate are positioned along the system's optical axis on opposite sides of the mirrors. The hyperbolic and elliptical mirrors are positioned on the same side of the system's optical axis as the reticle, and are relatively large in diameter as they are positioned on the high magnification side of the system. The hyperbolic and elliptical mirrors are relatively far off the optical axis and hence they have significant aspherical components in their curvatures. The convex spherical mirror is positioned on the optical axis, and has a substantially or perfectly spherical shape. The spherical concave mirror is positioned substantially on the opposite side of the optical axis from the hyperbolic and elliptical mirrors. Because it is positioned off-axis to a degree, the spherical concave mirror has some asphericity to counter aberrations. The spherical concave mirror forms a relatively large, uniform field on the wafer substrate. The mirrors can be tilted or decentered slightly to achieve further increase in the field size.

  15. Spherical aberrations of human astigmatic corneas.

    PubMed

    Zhao, Huawei; Dai, Guang-Ming; Chen, Li; Weeber, Henk A; Piers, Patricia A

    2011-11-01

    To evaluate whether the average spherical aberration of human astigmatic corneas is statistically equivalent to human nonastigmatic corneas. Spherical aberrations of 445 astigmatic corneas prior to laser vision correction were retrospectively investigated to determine Zernike coefficients for central corneal areas 6 mm in diameter using CTView (Sarver and Associates). Data were divided into groups according to cylinder power (0.01 to 0.25 diopters [D], 0.26 to 0.75 D, 0.76 to 1.06 D, 1.07 to 1.53 D, 1.54 to 2.00 D, and >2.00 D) and according to age by decade. Spherical aberrations were correlated with age and astigmatic power among groups and the entire population. Statistical analyses were conducted, and P<.05 was considered statistically significant. Mean patient age was 42.6±11 years. Astigmatic corneas had an average astigmatic power of 0.78±0.58 D and mean spherical aberration was 0.25±0.13 μm for the entire population and approximately the same (0.27 μm) for individual groups, ranging from 0.23 to 0.29 μm (P>.05 for all tested groups). Mean spherical aberration of astigmatic corneas was not correlated significantly with cylinder power or age (P>.05). Spherical aberrations are similar to those of nonastigmatic corneas, permitting the use of these additional data in the design of aspheric toric intra-ocular lenses. Copyright 2011, SLACK Incorporated.

  16. SEDIDAT: A BASIC program for the collection and statistical analysis of particle settling velocity data

    NASA Astrophysics Data System (ADS)

    Wright, Robyn; Thornberg, Steven M.

    SEDIDAT is a series of compiled IBM-BASIC (version 2.0) programs that direct the collection, statistical calculation, and graphic presentation of particle settling velocity and equivalent spherical diameter for samples analyzed using the settling tube technique. The programs follow a menu-driven format that is understood easily by students and scientists with little previous computer experience. Settling velocity is measured directly (cm,sec) and also converted into Chi units. Equivalent spherical diameter (reported in Phi units) is calculated using a modified Gibbs equation for different particle densities. Input parameters, such as water temperature, settling distance, particle density, run time, and Phi;Chi interval are changed easily at operator discretion. Optional output to a dot-matrix printer includes a summary of moment and graphic statistical parameters, a tabulation of individual and cumulative weight percents, a listing of major distribution modes, and cumulative and histogram plots of a raw time, settling velocity. Chi and Phi data.

  17. Hollow proppants and a process for their manufacture

    DOEpatents

    Jones, A.H.; Cutler, R.A.

    1985-10-15

    Hollow, fine-grained ceramic proppants are less expensive and improve fracture control when compared to conventional proppants (dense alumina, mullite, bauxite, zirconia, etc.). Hollow proppants of the present invention have been fabricated by spray drying, followed by sintering in order to obtain a dense case and a hollow core. These proppants generally have high sphericity and roundness (Krumbein sphericity and roundness greater than 0.8), have diameters on average between 2,250 and 125 [mu]m, depending on proppant size required, and have strength equal to or greater than that of sand. The hollow core, the size of which can be controlled, permits better fracture control in hydraulic fracturing treatments since the proppant can be transported in lower viscosity fluids. Hollow proppants produced at the same cost/weight as conventional proppants also provide for lower costs, since less weight is required to fill the same volume. The fine-grained (preferably less than 5 [mu]m in diameter) ceramic case provides the strength necessary to withstand closure stresses and prevent crushing. 6 figs.

  18. Spectroscopy of a plasma formed in the vicinity of implosion of the shock wave generated by underwater electrical explosion of spherical wire array

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Antonov, O.; Efimov, S.; Gurovich, V. Tz.

    The results of visible spectroscopy of the plasma formed inside a copper capillary placed at the equatorial plane of an underwater electrically exploded spherical wire array (30 mm in diameter; 40 wires, each of 100 μm in diameter) are reported. In the experiments, a pulsed power generator with current amplitude of ∼300 kA and rise time of ∼1.1 μs was used to produce wire array explosion accompanied by the formation of a converging strong shock wave. The data obtained support the assumption of uniformity of the shock wave along the main path of its convergence. The spectroscopic measurements show that this rather simple methodmore » of formation of a converging strong shock wave can be used successfully for studying the shock wave's interaction with matter and the evaporation processes of atoms from a target.« less

  19. Hollow proppants and a process for their manufacture

    DOEpatents

    Jones, Arfon H.; Cutler, Raymond A.

    1985-01-01

    Hollow, fine-grained ceramic proppants are less expensive and improve fracture control when compared to conventional proppants (dense alumina, mullite, bauxite, zirconia, etc.). Hollow proppants of the present invention have been fabricated by spray drying, followed by sintering in order to obtain a dense case and a hollow core. These proppants generally have high sphericity and roundness (Krumbein sphericity and roundness greater than 0.8), have diameters on average between 2250 and 125 .mu.m, depending on proppant size required, and have strength equal to or greater than that of sand. The hollow core, the size of which can be controlled, permits better fracture control in hydraulic fracturing treatments since the proppant can be transported in lower viscosity fluids. Hollow proppants produced at the same cost/weight as conventional proppants also provide for lower costs, since less weight is required to fill the same volume. The fine-grained (preferably less than 5 .mu.m in diameter) ceramic case provides the strength necessary to withstand closure stresses and prevent crushing.

  20. Synthesis of highly-monodisperse spherical titania particles with diameters in the submicron range.

    PubMed

    Tanaka, Shunsuke; Nogami, Daisuke; Tsuda, Natsuki; Miyake, Yoshikazu

    2009-06-15

    Monodisperse titania spheres with particle diameters in the range 380-960 nm were successfully synthesized by hydrolysis and condensation of titanium tetraisopropoxide. The preparation was performed using ammonia or dodecylamine (DDA) as a catalyst in methanol/acetonitrile co-solvent at room temperature. The samples were characterized by powder X-ray diffraction, scanning electron microscopy, transmission electron microscopy, dynamic light scattering, and nitrogen sorption measurement. The use of DDA was effective for the synthesis of monodisperse titania spheres with low coefficient of variation. When the titania spherical particles with coefficient of variation less than 4% were obtained, the colloidal crystallization easily occurred simply by centrifugation. The monodispersity was maintained even after crystallization of the particles by high temperature annealing. The titania particles prepared using DDA had mesopores near the surface of the spheres, providing high pore accessibility to the sphere from the surface-air interface. The particle size uniformity and photocatalytic reactivity of the titania prepared using DDA were higher than those of the titania prepared using ammonia.

  1. Efficacy and safety of proton pump inhibitors (PPIs) plus rebamipide for endoscopic submucosal dissection-induced ulcers: a meta-analysis.

    PubMed

    Wang, Jun; Guo, Xufeng; Ye, Chuncui; Yu, Shijie; Zhang, Jixiang; Song, Jia; Cao, Zhuo; Wang, Jing; Liu, Min; Dong, Weiguo

    2014-01-01

    To compare the efficacy of proton pump inhibitors (PPIs) with rebamipide versus PPIs alone for the treatment of ulcers after endoscopic submucosal dissection (ESD). PubMed, Web of Science, Medline, Embase, the Cochrane Central Register of Controlled Trials and China Naitonal Knowledge Infrastructure were searched up to the end of October 2013 in order to identify all randomized controlled trials reporting the effects of PPIs plus rebamipide on healing ulcers after ESD. The outcome measurement was complete ulcer healing. A total of six studies involving 724 patients were included. The pooled data suggested a significantly higher rate of ulcer healing after endoscopic therapy among patients treated with PPIs plus rebamipide than among those treated with PPIs alone [odds ratio (OR)=2.40, 95% confidence interval (CI): 1.68-3.44]. The subgroup analysis showed PPI plus rebamipide therapy to be more effective in healing ESD-induced ulcers than treatment with PPIs alone after both four (OR=2.22, 95%CI: 1.53-3.24) and eight weeks of treatment (OR=3.19, 95%CI: 1.22-8.31). In addition, the combination therapy was found to be significantly more effective than the use of PPIs alone for all ESD ulcers greater than 20 mm in size (OR=4.77, 95%CI: 2.22-10.26). There were no significant differences between the treatment groups with regard to ulcer location (low, middle or upper stomach) or the presence of absence of H. pylori infection. No serious adverse events were observed in either group. The results of this meta-analysis suggest that treatment with PPIs plus rebamipide is superior to PPI monotherapy for healing ESD-induced ulcers over four weeks, particularly large ulcers. However, more well-designed trials are needed to confirm these findings.

  2. Prospective, randomized comparison of a prototype endoscope with deflecting working channels versus a conventional double-channel endoscope for rectal endoscopic submucosal dissection in an established experimental simulation model (with video).

    PubMed

    Jung, Yunho; Kato, Masayuki; Lee, Jongchan; Gromski, Mark A; Chuttani, Ram; Matthes, Kai

    2013-11-01

    A prototype endoscope was designed to improve visualization and dissection of tissue with the use of 2 working channels with different deflections. To evaluate the efficacy and operability of a prototype endoscope in comparison with a conventional double-channel endoscope for rectal endoscopic submucosal dissection (ESD). Randomized, prospective, controlled, ex vivo study. Academic medical center. A total of 80 standardized artificial lesions measuring 3 × 3 cm were created approximately 5 cm from the anal verge in fresh ex vivo porcine colorectal specimens. Two endoscopists each completed 20 cases with the prototype endoscope and 20 cases with the conventional endoscope. An independent observer recorded procedure time, specimen size, en bloc resection, and perforation rate. For the ESD novice, the mean submucosal dissection time (10.5 ± 3.8 vs 14.9 ± 7.3 minutes; P = .024) and total procedure time (18.1 ± 5.2 vs 23.6 ± 8.2 minutes; P = .015) were significantly shorter in the prototype group in comparison with the conventional group. For the ESD expert, there was no significant difference between the mean circumferential resection, submucosal dissection, and total procedure time (prototype group 14.2 ± 6.0 minutes, conventional group 14.2 ± 8.8 minutes; P = .992). The overall perforation and en bloc resection rates were not significantly different between groups. Ex vivo study. In this ex vivo prospective comparison study, there was a technical advantage for the ESD novice with the prototype endoscope that resulted in a shorter procedure time, which was not observed for cases performed by the ESD expert. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  3. Endoscopic submucosal dissection for anorectal tumor with hemorrhoids close to the dentate line: a multicenter study of Hiroshima GI Endoscopy Study Group.

    PubMed

    Tamaru, Yuzuru; Oka, Shiro; Tanaka, Shinji; Hiraga, Yuko; Kunihiro, Masaki; Nagata, Shinji; Furudoi, Akira; Ninomiya, Yuki; Asayama, Naoki; Shigita, Kenjiro; Nishiyama, Soki; Hayashi, Nana; Chayama, Kazuaki

    2016-10-01

    The lower rectum close to the dentate line has distinct characteristics, making endoscopic submucosal dissection (ESD) of tumors challenging. We assessed clinical outcomes of ESD for such patients with hemorrhoids. Sixty-four patients (mean age, 68 years) underwent ESD for anorectal tumors close to the dentate line. We divided patients into those with (Group A, 45 patients) and without hemorrhoids (Group B, 19 patients). We examined en bloc and histological en bloc resection rates, procedure time, complication rates, and postoperative prognosis after ESD. The mean tumor size was 43 mm. Histologic diagnoses were adenoma (42 %, 27/64), carcinoma in situ (44 %, 28/64), and T1 carcinoma (14 %, 9/64). There was no significant difference in en bloc resection (93 %, 42/45 vs. 95 %, 18/19) or postoperative bleeding rates (16 %, 7/45 vs. 11 %, 2/19) between Groups A and B, respectively. The mean procedural durations were 120 and 124 min, respectively, in Groups A and B. No perforations occurred. There was no significant difference in postoperative anal pain rate between Groups A (18 %, 8/45) and B (16 %, 3/19), and it resolved within a few days in all cases. There was one case of stricture in Group B. Two patients with T1 carcinoma underwent additional surgery, one underwent chemotherapy, and five had no additional treatment. No recurrence occurred during the follow-up period of 38 months. ESD is safe and effective for anorectal tumors close to the dentate line in patients with hemorrhoids.

  4. Culture-independent analysis of bacterial communities in hemolymph of American lobsters with epizootic shell disease.

    PubMed

    Quinn, Robert A; Smolowitz, Roxanna; Chistoserdov, Andrei Y

    2013-03-26

    Epizootic shell disease (ESD) of the American lobster Homarus americanus H. Milne Edwards, 1837 is a disease of the carapace that presents grossly as large, melanized, irregularly shaped lesions, making the lobsters virtually unmarketable because of their grotesque appearance. We analyzed the bacterial communities present in the hemolymph of lobsters with and without ESD using nested-PCR of the 16S rRNA genes followed by denaturing gradient gel electrophoresis. All lobsters tested (n = 42) had bacterial communities in their hemolymph, and the community profiles were highly similar regardless of the sampling location or disease state. A number of bacteria were detected in a high proportion of samples and from numerous locations, including a Sediminibacterium sp. closely related to a symbiont of Tetraponera ants (38/42) and a Ralstonia sp. (27/42). Other bacteria commonly encountered included various Bacteroidetes, Pelomonas aquatica, and a Novosphingobium sp. One bacterium, a different Sediminibacterium sp., was detected in 20% of diseased animals (n = 29), but not in the lobsters without signs of ESD (n = 13). The bacteria in hemolymph were not the same as those known to be present in lesion communities except for the detection of a Thalassobius sp. in 1 individual. This work demonstrates that hemolymph bacteremia and the particular bacterial species present do not correlate with the incidence of ESD, providing further evidence that microbiologically, ESD is a strictly cuticular disease. Furthermore, the high incidence of the same species of bacteria in hemolymph of lobsters may indicate that they have a positive role in lobster fitness, rather than in disease, and further investigation of the role of bacteria in lobster hemolymph is required.

  5. Experimental application of pulsed laser-induced water jet for endoscopic submucosal dissection: mechanical investigation and preliminary experiment in swine.

    PubMed

    Sato, Chiaki; Nakano, Toru; Nakagawa, Atsuhiro; Yamada, Masato; Yamamoto, Hiroaki; Kamei, Takashi; Miyata, Go; Sato, Akira; Fujishima, Fumiyoshi; Nakai, Masaaki; Niinomi, Mitsuo; Takayama, Kazuyoshi; Tominaga, Teiji; Satomi, Susumu

    2013-05-01

    A current drawback of endoscopic submucosal dissection (ESD) for early-stage gastrointestinal tumors is the lack of instruments that can safely assist with this procedure. We have developed a pulsed jet device that can be incorporated into a gastrointestinal endoscope. Here, we investigated the mechanical profile of the pulsed jet device and demonstrated the usefulness of this instrument in esophageal ESD in swine. The device comprises a 5-Fr catheter, a 14-mm long stainless steel tube for generating the pulsed water jet, a nozzle and an optical quartz fiber. The pulsed water jet was generated at pulse rates of 3 Hz by irradiating the physiological saline (4°C) within the stainless steel tube with an holmium-doped yttrium-aluminum-garnet (Ho:YAG) laser at 1.1 J/pulse. Mechanical characteristics were evaluated using a force meter. The device was used only for the part of submucosal dissection in the swine ESD model. Tissues removed using the pulsed jet device and a conventional electrocautery device, and the esophagus, were histologically examined to assess thermal damage. The peak impact force was observed at a stand-off distance of 40 mm (1.1 J/pulse). ESD using the pulsed jet device was successful, as the tissue specimens showed precise dissection of the submucosal layer. The extent of thermal injury was significantly lower in the dissected bed using the pulsed jet device. The results showed that the present endoscopic pulsed jet system is a useful alternative for a safe ESD with minimum tissue injury. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.

  6. Endoscopic Submucosal Dissection (ESD) with Additional Therapy for Superficial Esophageal Cancer with Submucosal Invasion.

    PubMed

    Ikeda, Atsuki; Hoshi, Namiko; Yoshizaki, Tetsuya; Fujishima, Yoshimi; Ishida, Tsukasa; Morita, Yoshinori; Ejima, Yasuo; Toyonaga, Takashi; Kakechi, Yoshihiro; Yokosaki, Hiroshi; Azuma, Takeshi

    2015-01-01

    The standard treatment for submucosal esophageal cancer is esophagectomy or chemoradiotherapy (CRT). However, these treatment modalities could deteriorate the general condition and quality of life of the patients who are intolerant to invasive therapy. It is therefore important and beneficial to develop less invasive treatment protocols for these patients. The study included 43 patients who were clinically suspected of mucosa or submucosal esophageal cancer but underwent endoscopic submucosal dissection (ESD) as a primary treatment, due to the patients' poor performance statuses and/or preferences for less invasive therapy. According to the pathological findings and patient's general condition, whether the patient underwent additional treatments or remained hospitalized without additional treatments was thereafter decided for each patient. We retrospectively analyzed the outcomes of these patients. Fifteen patients underwent additional surgery, 11 patients underwent CRT/radiation therapy (RT) and 17 patients were followed without additional treatments. During the 3-year follow-up period, the relapse-free survival rates in the patients who received or did not receive additional treatments were 88% and 64%, respectively (95% confidence interval, 0.45-0.76, p=0.04). The relapse-free and overall survival rates in the patients with additional treatments were equivalent or superior to those described in previous reports of the standard treatments. Preceding ESD contributed to reduce the local relapse significantly to approximately 3.5% and additional CRT-related toxicities. Preceding ESD is very effective for the local control of cancer, and useful for histologically confirming the high-risk factors of relapse, such as ≥submucosal layer 2 (SM2) invasion and lymphovascular involvements. ESD with additional therapy may be a promising strategy for optimizing the selection of therapy depending on the patient's general condition.

  7. Efficacy of deep biopsy for subepithelial lesions in the upper gastrointestinal tract.

    PubMed

    Vaicekauskas, Rolandas; Stanaitis, Juozas; Valantinas, Jonas

    2016-01-01

    Accurate diagnosis of subepithelial lesions (SELs) in the gastrointestinal tract depends on a variety of methods: endoscopy, endoscopic ultrasound and different types of biopsy. Making an error-free diagnosis is vital for the subsequent application of an appropriate treatment. To evaluate the efficacy of deep biopsy via the endoscopic submucosal dissection (ESD) technique for SELs in the upper gastrointestinal tract. It was a case series study. Deep biopsy via the ESD technique was completed in 38 patients between November 2012 and October 2014. Thirty-eight SELs in the upper gastrointestinal tract of varying size (very small ≤ 1 cm, small 1-2 cm and large ≥ 2 cm) by means of the ESD technique after an incision with an electrosurgical knife of the overlying layers and revealing a small part of the lesion were biopsied under direct endoscopic view. Deep biopsy via the ESD technique was diagnostic in 28 of 38 patients (73.3%; 95% CI: 59.7-89.7%). The diagnostic yield for SELs with a clear endophytic shape increased to 91.3%. An evident endophytic appearance of a subepithelial lesion, the mean number of biopsied samples (6.65 ±1.36) and the total size in length of all samples per case (19.88 ±8.07 mm) were the main criteria influencing the positiveness of deep biopsy in the diagnostic group compared to the nondiagnostic one (p = 0.001; p = 0.025; p = 0.008). Deep biopsy via the ESD technique is an effective and safe method for the diagnosis of SELs especially with a clear endophytic appearance in a large number of biopsied samples.

  8. Improving the analyte ion signal in matrix-assisted laser desorption/ionization imaging mass spectrometry via electrospray deposition by enhancing incorporation of the analyte in the matrix.

    PubMed

    Malys, Brian J; Owens, Kevin G

    2017-05-15

    Matrix-assisted laser desorption/ionization (MALDI) is widely used as the ionization method in high-resolution chemical imaging studies that seek to visualize the distribution of analytes within sectioned biological tissues. This work extends the use of electrospray deposition (ESD) to apply matrix with an additional solvent spray to incorporate and homogenize analyte within the matrix overlayer. Analytes and matrix are sequentially and independently applied by ESD to create a sample from which spectra are collected, mimicking a MALDI imaging mass spectrometry (IMS) experiment. Subsequently, an incorporation spray consisting of methanol is applied by ESD to the sample and another set of spectra are collected. The spectra prior to and after the incorporation spray are compared to evaluate the improvement in the analyte signal. Prior to the incorporation spray, samples prepared using α-cyano-4-hydroxycinnamic acid (CHCA) and 2,5-dihydroxybenzoic acid (DHB) as the matrix showed low signal while the sample using sinapinic acid (SA) initially exhibited good signal. Following the incorporation spray, the sample using SA did not show an increase in signal; the sample using DHB showed moderate gain factors of 2-5 (full ablation spectra) and 12-336 (raster spectra), while CHCA samples saw large increases in signal, with gain factors of 14-172 (full ablation spectra) and 148-1139 (raster spectra). The use of an incorporation spray to apply solvent by ESD to a matrix layer already deposited by ESD provides an increase in signal by both promoting incorporation of the analyte within and homogenizing the distribution of the incorporated analyte throughout the matrix layer. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  9. Electron Stimulated Desorption Yields at the Mercury's Surface Based On Hybrid Simulation Results

    NASA Astrophysics Data System (ADS)

    Travnicek, P. M.; Schriver, D.; Orlando, T. M.; Hellinger, P.

    2016-12-01

    In terms of previous research concerning the solar wind sputtering process, most of the focus has been on ion sputtering by precipitating solar wind protons, however, precipitating electrons can also result in the desorption of neutrals and ions from Mercury's surface and represents a potentially significant source of exospheric and heavy ion components. Electron stimulated desorption (ESD) is not bound by optical selection rules and electron impact energies can vary over a much wider range, including core-level excitations that easily lead to multi-electron shake up events that can cascade into localized multiple charged states that Coulomb explode with extreme kinetic energy release (up to 8 eV = 186,000 K). While considered for the lunar exosphere, ESD has not been adequately studied or quantified as a producer of neutrals and ions. ESD is a well known process which involves the excitation (often ionization) of a surface target followed by charge ejection, bond breaking and ion expulsion due to the resultant Coulomb repulsion. Though the role of ESD processes has not been discussed much with respect to Mercury, the impinging energetic electrons that are transported through the magnetosphere and precipitate can induce significant material removal. Given the energetics and the wide band-gap nature of the minerals, the departing material may also be primarily ionic. The possible role of 5 eV - 1 keV electron stimulated desorption and dissociation in "weathering" the regolith can be significant. ESD yields will be calculated based on the ion and electron precipitation profiles for the already carried out hybrid and electron simulations. Neutral and ion cloud profiles around Mercury will be calculated and combined with those profiles expected from PSD and MIV.

  10. Prevention of esophageal stricture after endoscopic submucosal dissection: a systematic review and meta-analysis.

    PubMed

    Oliveira, J F; Moura, E G H; Bernardo, W M; Ide, E; Cheng, S; Sulbaran, M; Santos, C M L; Sakai, P

    2016-07-01

    Endoscopic submucosal dissection (ESD) of extensive superficial cancers of the esophagus may progress with high rates of postoperative stenosis, resulting in significantly decreased quality of life. Several therapies are performed to prevent this, but have not yet been compared in a systematic review. A systematic review of the literature and meta-analysis were performed using the MEDLINE, Embase, Cochrane, LILACS, Scopus, and CINAHL databases. Clinical trials and observational studies were searched from March 2014 to February 2015. Search terms included: endoscopy, ESD, esophageal stenosis, and esophageal stricture. Three retrospective and four prospective (three randomized) cohort studies were selected and involved 249 patients with superficial esophageal neoplasia who underwent ESD, at least two-thirds of the circumference. We grouped trials comparing different techniques to prevent esophagus stenosis post-ESD. We conducted different meta-analyses on randomized clinical trials (RCT), non-RCT, and global analysis. In RCT (three studies, n = 85), the preventive therapy decreased the risk of stenosis (risk difference = -0.36, 95 % CI -0.55 to -0.18, P = 0.0001). Two studies (one randomized and one non-randomized, n = 55) showed that preventative therapy lowered the average number of endoscopy dilatations (mean difference = -8.57, 95 % CI -13.88 to -3.25, P < 0.002). There were no significant differences in the three RCT studies (n = 85) in complication rates between patients with preventative therapy and those without (risk difference = 0.02, 95 % CI -0.09 to 0.14, P = 0.68). The use of preventive therapy after extensive ESD of the esophagus reduces the risk of stenosis and the number of endoscopic dilatations for resolution of stenosis without increasing the number of complications.

  11. Renal Artery Embolization Combined With Radiofrequency Ablation in a Porcine Kidney Model: Effect of Small and Narrowly Calibrated Microparticles as Embolization Material on Coagulation Diameter, Volume, and Shape

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sommer, C. M., E-mail: christof.sommer@med.uni-heidelberg.de; Kortes, N.; Zelzer, S.

    2011-02-15

    The purpose of this study was to evaluate the effect of renal artery embolization with small and narrowly calibrated microparticles on the coagulation diameter, volume, and shape of radiofrequency ablations (RFAs) in porcine kidneys. Forty-eight RFAs were performed in 24 kidneys of 12 pigs. In 6 animals, bilateral renal artery embolization was performed with small and narrowly calibrated microparticles. Upper and lower kidney poles were ablated with identical system parameters. Applying three-dimensional segmentation software, RFAs were segmented on registered 2 mm-thin macroscopic slices. Length, depth, width, volume{sub s}egmented, and volume{sub c}alculated were determined to describe the size of the RFAs.more » To evaluate the shape of the RFAs, depth-to-width ratio (perfect symmetry-to-lesion length was indicated by a ratio of 1), sphericity ratio (perfect sphere was indicated by a sphericity ratio of 1), eccentricity (perfect sphere was indicated by an eccentricity of 0), and circularity (perfect circle was indicated by a circularity of 1) were determined. Embolized compared with nonembolized RFAs showed significantly greater depth (23.4 {+-} 3.6 vs. 17.2 {+-} 1.8 mm; p < 0.001) and width (20.1 {+-} 2.9 vs. 12.6 {+-} 3.7 mm; p < 0.001); significantly larger volume{sub s}egmented (8.6 {+-} 3.2 vs. 3.0 {+-} 0.7 ml; p < 0.001) and volume{sub c}alculated (8.4 {+-} 3.0 ml vs. 3.3 {+-} 1.1 ml; p < 0.001); significantly lower depth-to-width (1.17 {+-} 0.10 vs. 1.48 {+-} 0.44; p < 0.05), sphericity (1.55 {+-} 0.44 vs. 1.96 {+-} 0.43; p < 0.01), and eccentricity (0.84 {+-} 0.61 vs. 1.73 {+-} 0.91; p < 0.01) ratios; and significantly greater circularity (0.62 {+-} 0.14 vs. 0.45 {+-} 0.16; p < 0.01). Renal artery embolization with small and narrowly calibrated microparticles affected the coagulation diameter, volume, and shape of RFAs in porcine kidneys. Embolized RFAs were significantly larger and more spherical compared with nonembolized RFAs.« less

  12. Neutron spectra measurement and calculations using data libraries CIELO, JEFF-3.2 and ENDF/B-VII.1 in iron benchmark assemblies

    NASA Astrophysics Data System (ADS)

    Jansky, Bohumil; Rejchrt, Jiri; Novak, Evzen; Losa, Evzen; Blokhin, Anatoly I.; Mitenkova, Elena

    2017-09-01

    The leakage neutron spectra measurements have been done on benchmark spherical assemblies - iron spheres with diameter of 20, 30, 50 and 100 cm. The Cf-252 neutron source was placed into the centre of iron sphere. The proton recoil method was used for neutron spectra measurement using spherical hydrogen proportional counters with diameter of 4 cm and with pressure of 400 and 1000 kPa. The neutron energy range of spectrometer is from 0.1 to 1.3 MeV. This energy interval represents about 85 % of all leakage neutrons from Fe sphere of diameter 50 cm and about of 74% for Fe sphere of diameter 100 cm. The adequate MCNP neutron spectra calculations based on data libraries CIELO, JEFF-3.2 and ENDF/B-VII.1 were done. Two calculations were done with CIELO library. The first one used data for all Fe-isotopes from CIELO and the second one (CIELO-56) used only Fe-56 data from CIELO and data for other Fe isotopes were from ENDF/B-VII.1. The energy structure used for calculations and measurements was 40 gpd (groups per decade) and 200 gpd. Structure 200 gpd represents lethargy step about of 1%. This relatively fine energy structure enables to analyze the Fe resonance neutron energy structure. The evaluated cross section data of Fe were validated on comparisons between the calculated and experimental spectra.

  13. Supportive techniques and devices for endoscopic submucosal dissection of gastric cancer.

    PubMed

    Sakurazawa, Nobuyuki; Kato, Shunji; Fujita, Itsuo; Kanazawa, Yoshikazu; Onodera, Hiroyuki; Uchida, Eiji

    2012-06-16

    The indications for endoscopic treatment have expanded in recent years, and relatively intestinal-type mucosal stomach carcinomas with a low potential for metastasis are now often resected en bloc by endoscopic submucosal dissection (ESD), even if they measure over 20 mm in size. However, ESD requires complex maneuvers, which entails a long operation time, and is often accompanied by complications such as bleeding and perforation. Many technical developments have been implemented to overcome these complications. The scope, cutting device, hemostasis device, and other supportive devices have been improved. However, even with these innovations, ESD remains a potentially complex procedure. One of the major difficulties is poor visualization of the submucosal layer resulting from the poor countertraction afforded during submucosal dissection. Recently, countertraction devices have been developed. In this paper, we introduce countertraction techniques and devices mainly for gastric cancer.

  14. Effects of Concentration of Nanoscale Tin-Doped Indium Oxide on Electrical Breakdown of High-Resistance Liquid Crystal

    NASA Astrophysics Data System (ADS)

    Liang, Bau-Jy; Liu, Don-Gey; Chang, Chih-Yuan; Shie, Wun-Yi

    2011-05-01

    According to our previous study, a high concentration of nanoscale tin-doped indium oxide (ITO) may be beneficial for protecting liquid crystal (LC) against attacks by electrostatic discharge (ESD). In this study, the influence of high-voltage stresses in an ESD test was investigated for cells doped with different concentrations of ITO. It was found that nano-ITO with a concentration of 0.4% in weight ratio deteriorated the physical properties of LC of transparency transition and charge retention. However, our experiment showed that the capability of ESD protection for the doped LC was still improved at the ITO concentration of 0.4 wt %. This finding supports the proposed model in our previous report. The role of ITO in the LC is not always beneficial, as discussed in this paper.

  15. Integrating Sustainable Development Concept into Science Education Program Is Not Enough; We Need Competent Science Teachers for Education for Sustainable Development--Turkish Experience

    ERIC Educational Resources Information Center

    Karaarslan, Güliz; Teksöz, Gaye

    2016-01-01

    In order to educate science teachers for a sustainable future, recent discussions are going on related to collaboration between science education and education for sustainable development (ESD). Still, ESD has been in a development stage and needs to be improved in terms of developing teacher competencies. Therefore, in this study we focused on…

  16. Education Service Districts in Oregon. A Progress Report to the 61st Legislative Assembly, as Required by Chapter 445, Oregon Laws 1979, House Bill 2393, ORS 334.175 Sec. 2.

    ERIC Educational Resources Information Center

    Oregon State Dept. of Education, Salem.

    Through a wide variety of programs and services, Oregon's 25 educational service districts (ESDs) link the state Department of Education with local school districts while helping districts provide a cost-effective education and fostering equal educational opportunity statewide. This report lists the general ESD programs and services required by…

  17. Search and Retrieval Index to EOS/ESD Symposium Proceedings - 1979 to 1984.

    DTIC Science & Technology

    1985-04-15

    This book contains indexes used in searching for information contained in papers produced in Electrical Overstress/Electrostatic Discharge (EOS/ESD) Symposium 1979 to 1984. These indexes are the Alphabetical List of Index Terms, Subject Index, Author Index , Corporate Index, Keywords in Title Index, and Chronological List of Papers Index. These indexes provide a clear, easy-to-read, and concise method of searching for and

  18. Grounding Headphones for Protection Against ESD

    NASA Technical Reports Server (NTRS)

    Peters, John; Youngquist, Robert C.

    2004-01-01

    A simple alternative technique has been devised protecting delicate equipment against electrostatic discharge (ESD) in settings in which workers wear communication headsets. In the original setting in which the technique was devised, the workers who wear the headsets also wear anti-ESD grounding straps on their wrists. The alternative technique eliminates the need for the wrist grounding straps by providing for grounding through the headsets. In place of the electrically insulating foam pads on the headsets, one installs pads made of electrically conductive foam like that commonly used to protect electronic components. Grounding wires are attached to the conductive foam pads, then possibly to the shielding cable which may be grounded to the backshell on the connector. The efficacy of this technique in protecting against ESD has been verified in experiments. The electrical resistance of the pads is a few megohms - about the same as that of a human body between the fingers of opposite hands and, hence, low enough for grounding. The only drawback of the technique is that care must be taken to place the foam pads in contact with the user s skin: any hair that comes between the foam pads and the skin must be pushed aside because hair is electrically insulating and thus prevents adequate grounding.

  19. Successful Endoscopic Submucosal Dissection of a Large Terminal Ileal Lipoma

    PubMed Central

    Noda, Hisatsugu; Ogasawara, Naotaka; Tamura, Yasuhiro; Kondo, Yoshihiro; Izawa, Shinya; Ebi, Masahide; Funaki, Yasushi; Sasaki, Makoto; Kasugai, Kunio

    2016-01-01

    A 78-year-old woman who had recurrent right lower abdominal pain for about 1 year underwent computed tomography (CT) because of a follow-up observation 1 year after right breast cancer surgery. CT revealed a tumor in the colon. The patient was referred to our hospital for detailed examinations. An abdominal CT showed a low-density tumor of approximately 30 mm in the ascending colon, and the CT density inside the tumor was same as that of fatty tissues. A subsequent colonoscopy showed a submucosal tumor (SMT) in the proximal ascending colon developing from the terminal ileum. A colonoscopic ultrasonography revealed that the SMT was a high-echoic mass mainly localized in the submucosal layer. Based on the findings from CT, colonoscopy, and colonoscopic ultrasonography, the SMT was diagnosed as a pedunculated lipoma originating from the terminal ileum and treated with endoscopic submucosal dissection (ESD) because of recurrent abdominal pain. The 40-mm tumor was resected en bloc without complications. ESD may be more appropriate than polypectomy and surgery for removal of small intestinal tumors, because ESD allows direct visualization of the cutting line and exactly dissects the submucosal layers without damaging the muscular layers. ESD is a potentially useful treatment to remove intestinal lipomas. PMID:27843426

  20. High Current ESD Test of Advanced Triple Junction Solar Array Coupon

    NASA Technical Reports Server (NTRS)

    Wright, Kenneth H., Jr.; Schneider, Todd A.; Vaughn, Jason A.; Hoang, Bao; Wong, Frankie

    2014-01-01

    Testing was conducted on an Advanced Triple Junction (ATJ) coupon that was part of a risk reduction effort in the development of a high-powered solar array design by Space Systems Loral, LLC (SSL). The ATJ coupon was a small, 4-cell, two-string configuration of flight-type design that has served as the basic test coupon design used in previous SSL environmental aging campaigns. The objective of the present test was to evaluate the performance of the coupon after being subjected to induced electrostatic discharge (ESD) testing at two string voltages (100 V, 150 V) and four string currents (1.65 A, 2.0 A, 2.475 A, and 3.3 A). An ESD test circuit, unique to SSL solar array design, was built that simulates the effect of missing cells and strings in a full solar panel with special primary arc flashover circuitry. A total of 73 primary arcs were obtained that included 7 temporary sustained arcs (TSA) events. The durations of the TSAs ranged from 50 micro-seconds to 2.75 milli-seconds. All TSAs occurred at a string voltage of 150 V. Post-ESD functional testing showed that no degradation occurred due to the TSA events. These test results point to a robust design for application to a high-current, high-power mission.

  1. Sac surgery results as a function of preoperative distress level.

    PubMed

    Tyagi, Isha; Goyal, Amit; Syal, Rajan

    2006-10-01

    To evaluate the postoperative status of the patients after endolymphatic sac decompression (ESD) for intractable unilateral definite Ménière's disease (MD) using the American Academy of Otolaryngology-Head and Neck Surgery (AAO-HNS) 1995 criteria and to discuss the current status of ESD in the management of MD, especially after the wide use of intratympanic administration of gentamicin for the treatment of intractable MD. Retrospective questionnaire-based analysis. Thirty-nine patients who had undergone ESD between 1996 and May 2003 at Sanjay Gandhi Post Graduate Institute of Medical Sciences, Lucknow, India, were evaluated via a set format according to AAO-HNS 1995 guidelines. Their preoperative and postoperative data were compared. We found significant improvement in functional level scales (FLSs) in 84.6%, Class A vertigo control in 82%, and improved disability outcome in 87% of cases after surgery at a median postoperative follow-up of 29 months. All the patients showing significant improvement in FLS were preoperatively in scale 4 or more, and all the patients whose treatment failed were in scale 3 or less. We recommend continued use of ESD in indicated patients. We found a positive relation between preoperative distress level of the patient and postoperative improvement in FLSs; any such relationship should be investigated with a larger sample.

  2. Prevention of esophageal strictures after endoscopic submucosal dissection

    PubMed Central

    Kobayashi, Shinichiro; Kanai, Nobuo; Ohki, Takeshi; Takagi, Ryo; Yamaguchi, Naoyuki; Isomoto, Hajime; Kasai, Yoshiyuki; Hosoi, Takahiro; Nakao, Kazuhiko; Eguchi, Susumu; Yamamoto, Masakazu; Yamato, Masayuki; Okano, Teruo

    2014-01-01

    Endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD) have recently been accepted as less invasive methods for treating patients with early esophageal cancers such as squamous cell carcinoma and dysplasia of Barrett’s esophagus. However, the large defects in the esophageal mucosa often cause severe esophageal strictures, which dramatically reduce the patient’s quality of life. Although preventive endoscopic balloon dilatation can reduce dysphagia and the frequency of dilatation, other approaches are necessary to prevent esophageal strictures after ESD. This review describes several strategies for preventing esophageal strictures after ESD, with a particular focus on anti-inflammatory and tissue engineering approaches. The local injection of triamcinolone acetonide and other systemic steroid therapies are frequently used to prevent esophageal strictures after ESD. Tissue engineering approaches for preventing esophageal strictures have recently been applied in basic research studies. Scaffolds with temporary stents have been applied in five cases, and this technique has been shown to be safe and is anticipated to prevent esophageal strictures. Fabricated autologous oral mucosal epithelial cell sheets to cover the defective mucosa similarly to how commercially available skin products fabricated from epidermal cells are used for skin defects or in cases of intractable ulcers. Fabricated autologous oral-mucosal-epithelial cell sheets have already been shown to be safe. PMID:25386058

  3. Improving marine disease surveillance through sea temperature monitoring, outlooks and projections

    PubMed Central

    Maynard, Jeffrey; van Hooidonk, Ruben; Harvell, C. Drew; Eakin, C. Mark; Liu, Gang; Willis, Bette L.; Williams, Gareth J.; Dobson, Andrew; Heron, Scott F.; Glenn, Robert; Reardon, Kathleen; Shields, Jeffrey D.

    2016-01-01

    To forecast marine disease outbreaks as oceans warm requires new environmental surveillance tools. We describe an iterative process for developing these tools that combines research, development and deployment for suitable systems. The first step is to identify candidate host–pathogen systems. The 24 candidate systems we identified include sponges, corals, oysters, crustaceans, sea stars, fishes and sea grasses (among others). To illustrate the other steps, we present a case study of epizootic shell disease (ESD) in the American lobster. Increasing prevalence of ESD is a contributing factor to lobster fishery collapse in southern New England (SNE), raising concerns that disease prevalence will increase in the northern Gulf of Maine under climate change. The lowest maximum bottom temperature associated with ESD prevalence in SNE is 12°C. Our seasonal outlook for 2015 and long-term projections show bottom temperatures greater than or equal to 12°C may occur in this and coming years in the coastal bays of Maine. The tools presented will allow managers to target efforts to monitor the effects of ESD on fishery sustainability and will be iteratively refined. The approach and case example highlight that temperature-based surveillance tools can inform research, monitoring and management of emerging and continuing marine disease threats. PMID:26880840

  4. Improving marine disease surveillance through sea temperature monitoring, outlooks and projections.

    PubMed

    Maynard, Jeffrey; van Hooidonk, Ruben; Harvell, C Drew; Eakin, C Mark; Liu, Gang; Willis, Bette L; Williams, Gareth J; Groner, Maya L; Dobson, Andrew; Heron, Scott F; Glenn, Robert; Reardon, Kathleen; Shields, Jeffrey D

    2016-03-05

    To forecast marine disease outbreaks as oceans warm requires new environmental surveillance tools. We describe an iterative process for developing these tools that combines research, development and deployment for suitable systems. The first step is to identify candidate host-pathogen systems. The 24 candidate systems we identified include sponges, corals, oysters, crustaceans, sea stars, fishes and sea grasses (among others). To illustrate the other steps, we present a case study of epizootic shell disease (ESD) in the American lobster. Increasing prevalence of ESD is a contributing factor to lobster fishery collapse in southern New England (SNE), raising concerns that disease prevalence will increase in the northern Gulf of Maine under climate change. The lowest maximum bottom temperature associated with ESD prevalence in SNE is 12 °C. Our seasonal outlook for 2015 and long-term projections show bottom temperatures greater than or equal to 12 °C may occur in this and coming years in the coastal bays of Maine. The tools presented will allow managers to target efforts to monitor the effects of ESD on fishery sustainability and will be iteratively refined. The approach and case example highlight that temperature-based surveillance tools can inform research, monitoring and management of emerging and continuing marine disease threats. © 2016 The Authors.

  5. Design study of dedicated brain PET with polyhedron geometry.

    PubMed

    Shi, Han; Du, Dong; Xu, JianFeng; Su, Zhihong; Peng, Qiyu

    2015-01-01

    Despite being the conventional choice, whole body PET cameras with a 76 cm diameter ring are not the optimal means of human brain imaging. In fact, a dedicated brain PET with a better geometrical structure has the potential to achieve a higher sensitivity, a higher signal-to-noise ratio, and a better imaging performance. In this study, a polyhedron geometrical dedicated brain PET (a dodecahedron design) is compared to three other candidates via their geometrical efficiencies by calculating the Solid Angle Fractions (SAF); the three other candidates include a spherical cap design, a cylindrical design, and the conventional whole body PET. The spherical cap and the dodecahedron have an identical SAF that is 58.4% higher than that of a 30 cm diameter cylinder and 5.44 times higher than that of a 76 cm diameter cylinder. The conceptual polygon-shape detectors (including pentagon and hexagon detectors based on the PMT-light-sharing scheme instead of the conventional square-shaped block detector module) are presented for the polyhedron PET design. Monte Carlo simulations are performed in order to validate the detector decoding. The results show that crystals in a pentagon-shape detector can be successfully decoded by Anger Logic. The new detector designs support the polyhedron PET investigation.

  6. Core-shell monodisperse spherical mSiO2/Gd2O3:Eu3+@mSiO2 particles as potential multifunctional theranostic agents

    NASA Astrophysics Data System (ADS)

    Eurov, Daniil A.; Kurdyukov, Dmitry A.; Kirilenko, Demid A.; Kukushkina, Julia A.; Nashchekin, Alexei V.; Smirnov, Alexander N.; Golubev, Valery G.

    2015-02-01

    Core-shell nanoparticles with diameters in the range 100-500 nm have been synthesized as monodisperse spherical mesoporous (pore diameter 3 nm) silica particles with size deviation of less than 4 %, filled with gadolinium and europium oxides and coated with a mesoporous silica shell. It is shown that the melt technique developed for filling with gadolinium and europium oxides provides a nearly maximum filling of mesopores in a single-run impregnation, with gadolinium and europium uniformly distributed within the particles and forming no bulk oxides on their surface. The coating with a shell does not impair the monodispersity and causes no coagulation. The coating technique enables controlled variation of the shell thickness within the range 5-100 % relative to the core diameter. The thus produced nanoparticles are easily dispersed in water, have large specific surface area (300 m2 g-1) and pore volume (0.3 cm3 g-1), and are bright solid phosphor with superior stability in aqueous media. The core-shell structured particles can be potentially used for cancer treatment as a therapeutic agent (gadolinium neutron-capture therapy and drug delivery system) and, simultaneously, as a multimodal diagnostic tool (fluorescence and magnetic resonance imaging), thereby serving as a multifunctional theranostic agent.

  7. Flow and criticality in the open cycle gas core.

    NASA Technical Reports Server (NTRS)

    Kunze, J. F.; Lofthouse, J. H.

    1971-01-01

    A series of flowing gas experiments using air, argon, and freon has been conducted in Idaho. The purpose is to study methods of obtaining flow patterns which would create maximum possible system reactivity consistent with an acceptably low uranium to coolant-gas loss ratio. These have been conducted on both ?two-dimensional' and truly three-dimensional spherical configurations of diameters 18 to 42 inches. The larger diameter is that proposed for a minimum cost flowing gas critical experiment, and the size extremes make extrapolations to the large 6 and 8 foot diameter configurations more reliable. Results show that large enough inner gas (fuel) volume fractions can be achieved to attain criticality.

  8. The Intravitreal Autologous Platelet Concentrate Injection as an Adjunct of Vitrectomy for the Treatment of Refractory Macular Holes

    ClinicalTrials.gov

    2014-03-06

    Macular Hole With High Myopia (Spherical Equivalent ≤ -6.0 Diopters) or,; Large Size Macular Hole (Diameter > 600 Microns) or; Recurred or Failed Macular Hole From Previous Surgery; or Chronic Macular Hole (Symptom Duration > 6 Months)

  9. Spherical and tubule nanocarriers for sustained drug release

    PubMed Central

    Shutava, T.; Fakhrullin, R.; Lvov, Y.

    2014-01-01

    We discuss new trends in Layer-by-Layer (LbL) encapsulation of spherical and tubular cores of 50–150 nm diameter and loaded with drugs. This core size decrease (from few micrometers to a hundred of nanometers) for LbL encapsulation required development of sonication assistant non-washing technique and shell PEGylation to reach high colloidal stability of drug nanocarriers at 2–3 mg/mL concentration in isotonic buffers and serum. For 120–170 nm spherical LbL nanocapsules of low soluble anticancer drugs, polyelectrolyte shell thickness controls drug dissolution. As for nanotube carriers, we concentrated on natural halloysite clay nanotubes as cores for LbL encapsulation that allows high drug loading and sustains its release over tens and hundreds hours. Further drug release prolongation was reached with formation of the tube-end stoppers. PMID:25450068

  10. New host record of avian tuberculosis in an American white pelican, Pelecanus erythrorhynchos

    USGS Publications Warehouse

    Nol, P.; Brannian, R.E.; Berlowski, B.M.; Wolcott, M.J.; Rocke, T.E.

    2003-01-01

    An American white pelican (P. erythrorhyncos) was captured in August 1999 in California, USA. The bird was unable to fly away or evade the boat, and showed considerable aggression when captured. Numerous multifocal, 1 mm diameter, yellow masses were observed throughout the lungs and air sacs. The liver was yellow. A 6 cm diameter, firm spherical mass was present in the abdominal cavity, distal to the liver. Aspergillus spp. were cultured from the air sac tissue. Mycobacterium avium was identified from the splenic mass.

  11. Electrospark Deposition for Depot- and Field-Level Component Repair and Replacement of Hard Chromium Plating

    DTIC Science & Technology

    2008-02-01

    with an ASAP proprietary process. Corrosion applications frequently are addressed with iron- aluminide and nickel alloys such as Inconel 625 alloy...IN625) and Hastelloy C-22. Wear applications commonly treated with ESD include cutting edges of chipper knives, saw teeth, and mower blades ; wear...Applications for ESD repair include components of steel, stainless steel, nickel- and cobalt-based superalloys, aluminum, Monel, titanium , and magnesium

  12. NASA Workmanship Hot Topics: Water Soluble Flux and ESD Charge Device Model

    NASA Technical Reports Server (NTRS)

    Plante, Jeannette F.

    2009-01-01

    This slide presentation reviews two topics of interest to NASA Workmanship: (1) Water Soluble Flux (WSF) and Electrostatic Discharge (ESD) safety. In the first topic, WSF, the presentation reviews voiding and the importance of cleanliness in using WSF for welding and soldering operations. The second topic reviews the NASA-HDBK-8739.21 for Human Body Model, and Machine Model safety methods, and challenges associated with the Charged Device Model (CDM)

  13. ESD Protective Material and Equipment: A Critical Review

    DTIC Science & Technology

    1982-04-01

    having touched it. It is also of utmost importance that the resistivity of the work surface not change appreciably with changes in temperature , humidity...settings, e.g., temperature . No attempt was made to estimate the relative ease of heat-sealability of the bag materials, all of which use polyethylene...weapon in the battle against ESD. They function in two different ways. First, they reduce the materials’ coefficient of friction by increasing surface

  14. Spacecraft Charging Standard Report.

    DTIC Science & Technology

    1980-09-30

    SSPM include: SAMPLE POTENTIAL (with respect to S/C ground) Aluminized Kapton -2.0 kV Silvered Teflon -4.0 kV Astroquartz -3.7 kV 50.3 Analysis. As...and potential gradients on the space vehicle (candidate spacecraft locations for ESD tests) (The NASCAP computer code, when validated, will be useful...The coupling analysis should then determine as a minimum: I. electromagnetic fields generated interior to the space vehicle due to ESD 2. induced

  15. Sensitivity Testing of RDX/Aluminum Powdered Explosive Mixtures for the Improved Dispersed Explosives (IDX) Project

    DTIC Science & Technology

    1993-04-01

    perpendicular to the pipe axis. During assembly, the threads are lubricated and Teflon tape is used for sealing. Aluminum witness plates (25.4 mm thick...3.3 Electrostatic Discharge ( ESD ) ................................. 7 4. INTERMEDIATE-SCALE SENSITIVITY TESTING ..................... 8 4.1 Card Gap...tests include the DWIT, friction, and electrostatic discharge ( ESD ) tests. The purpose of these tests is to enable the researcher to ensure that the

  16. Charging/discharge events in coated spacecraft polymers during electron beam irradiation in a scanning electron microscope

    NASA Astrophysics Data System (ADS)

    Czeremuszkin, G.; Latrèche, M.; Wertheimer, M. R.

    2001-12-01

    Spacecraft, such as those operating in geosynchronous orbit (GEO), can be subjected to intense irradiation by charged particles, for example high-energy (e.g. 20 keV) electrons. The surfaces of dielectric materials (for example, polymers used as "thermal blankets") can therefore become potential sites for damaging electrostatic discharge (ESD) pulse events. We simulate these conditions by examining small specimens of three relevant polymers (polyimide, polyester and fluoropolymer), both bare and coated, in a scanning electron microscope (SEM). The coatings examined include commercial indium-tin oxide (ITO), and thin films of SiO 2 and a-Si:H deposited by plasma-enhanced chemical vapor deposition (PECVD). All coatings are found to greatly modify the observed ESD behavior, compared with that of the bare polymer counterparts. These observations are explained in terms of the model for ESD pulses proposed by Frederickson.

  17. Effect of Electrostatic Discharge on Electrical Characteristics of Discrete Electronic Components

    NASA Technical Reports Server (NTRS)

    Wysocki, Phil; Vashchenko, Vladislav; Celaya, Jose; Saha, Sankalita; Goebel, Kai

    2009-01-01

    This article reports on preliminary results of a study conducted to examine how temporary electrical overstress seed fault conditions in discrete power electronic components that cannot be detected with reliability tests but impact longevity of the device. These defects do not result in formal parametric failures per datasheet specifications, but result in substantial change in the electrical characteristics when compared with pristine device parameters. Tests were carried out on commercially available 600V IGBT devices using transmission line pulse (TLP) and system level ESD stress. It was hypothesized that the ESD causes local damage during the ESD discharge which may greatly accelerate degradation mechanisms and thus reduce the life of the components. This hypothesis was explored in simulation studies where different types of damage were imposed to different parts of the device. Experimental results agree qualitatively with the simulation for a number of tests which will motivate more in-depth modeling of the damage.

  18. Chasing our tails: psychological, institutional and societal paradoxes in natural resource management, sustainability, and climate change in Australia.

    PubMed

    Browne, A L; Bishop, B J

    2011-06-01

    Natural Resource Management (NRM) and Ecologically Sustainable Development (ESD) have been guiding frameworks in Australia for a number of decades. Recently, NRM and ESD have become central to climate change mitigation. In this paper, we explore the psychological paradoxes that function within climate change settings, with particular attention devoted to the way that research and development reinforces these paradoxes by advocating for participatory forms of inquiry. Paradox emerges in NRM at psychological, institutional, and organisational levels. Paradoxes are also features of different forms of democracy such as neoliberal and participatory democracy. Although NRM, ESD and climate change are often conceptualised as distinct issue domains, these policy areas are fundamentally interconnected in both theory and in practice. This interconnection between these policy and research settings, reflections on paradox, and the experience of incorporating community psychology into the paradoxical settings of NRM and climate change are captured in this paper.

  19. Endoscopic submucosal dissection using flexknife.

    PubMed

    Kodashima, Shinya; Fujishiro, Mitsuhiro; Yahagi, Naohisa; Kakushima, Naomi; Omata, Masao

    2006-01-01

    Although the standard treatment for early-stage gastrointestinal tumors is still surgical resection, endoscopic resection has been accepted for some of these lesions, especially in Japan. However, the indication was limited until recently to achieve en bloc resection and prevent local recurrence. To overcome the disadvantage of endoscopic resection with conventional endoscopic mucosal resection (EMR), several investigators, including us, have developed a new endoscopic resection technique: endoscopic submucosal dissection (ESD). ESD is a remarkable technique that enables to remove the lesions en bloc regardless of size, shape, coexisting ulcer, and location. Nowadays, several knives are available for ESD, such as the needle knife, insulation-tipped (IT) knife, Hookknife, triangle-tipped (TT) knife, and Flexknife. Each of them has some merits and demerits, and the ways to use the knives are different. We summarize here how to use the Flexknife, which we made ourselves in cooperation with the Olympus Company, and how we use the technique in our hospital.

  20. Chalcogenide glass microlenses by inkjet printing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanchez, Eric A.; Waldmann, Maike; Arnold, Craig B.

    We demonstrate micrometer scale mid-IR lenses for integrated optics, using solution-based inkjet printing techniques and subsequent processing. Arsenic sulfide spherical microlenses with diameters of 10-350 {mu}m and focal lengths of 10-700 {mu}m have been fabricated. The baking conditions can be used to tune the precise focal length.

  1. Odd Length Contraction

    NASA Astrophysics Data System (ADS)

    Smarandache, Florentin

    2013-09-01

    Let's denote by VE the speed of the Earth and byVR the speed of the rocket. Both travel in the same direction on parallel trajectories. We consider the Earth as a moving (at a constant speed VE -VR) spacecraft of almost spherical form, whose radius is r and thus the diameter 2r, and the rocket as standing still. The non-proper length of Earth's diameter, as measured by the astronaut is: L = 2 r√{ 1 -|/VE -VR|2 c2 } < 2 r . Therefore Earth's diameter shrinks in the direction of motion, thus Earth becomes an ellipsoid - which is untrue. Planet Earth may increase or decrease its diameter (volume), but this would be for other natural reasons, not because of a...flying rocket! Also, let's assume that the astronaut is laying down in the direction of motion. Therefore, he would also shrink, or he would die!

  2. Impacts of ESD Reliability by Different Layout Engineering in the 0.25-μm 60-V High-Voltage LDMOS Devices

    NASA Astrophysics Data System (ADS)

    Chen, Shen-Li; Lin, Chun-Ju; Yu-Ting, Huang

    2018-02-01

    How to effectively enhance the reliability robustness in high-voltage (HV) BCD [(bipolar) complementary metal-oxide semiconductor (CMOS) diffusion metaloxide semiconductor (DMOS)] processes is an important issue. Influences of layouttype dependences on anti-electrostatic discharge (ESD) robustness in a 0.25-μm 60-V process will be studied in this chapter, which includes, in part (1), the traditional striped-type n-channel lateral-diffused MOSFET (nLDMOS), waffle-type nLDMOS, and nLDMOS embedded with a "p-n-p"-arranged silicon-controlled rectifier (SCR) devices in the drain side; and in part (2) a p-channel LDMOS (pLDMOS) with an embedded "p-n-p-n-p"-arranged-type SCR in the drain side (diffusion regions of the drain side is P+-N+-P+-N+-P+). Then, these LDMOS devices are used to evaluate the influence of layout architecture on trigger voltage (Vt1), holding voltage (Vh), and secondary breakdown current (It2). Eventually, the sketching of the layout pattern of a HV LDMOS is a very important issue in the anti-ESD consideration. Also, in part (1), the waffle-type nLDMOS DUT contributes poorly to It2 robustness due to the non-uniform turned-on phenomenon and a narrow channel width per unit finger. Therefore, the It2 robustness of a waffle-type nLDMOS device is decreased about 17% as compared to a traditional striped-type nLDMOS device (reference DUT-1). The ESD abilities of traditional stripedtype and waffle-type nLDMOS devices with an embedded SCR ("p-n-p"-manner arrangement in the drain side) are better than a traditional nLDMOS 224.4% in average. Noteworthy, the nLDMOS-SCR with the "p-n-p" -arranged-type in the drainend is a good structure for the anti-ESD reliability especially in HV usages. Furthermore, in part (2) this layout manner of P+ discrete-island distributions in the drain-side have some impacts on the anti-ESD and anti-latch-up (LU) immunities. All of their It2 values have reached above 6 A; however, the major repercussion is that the Vh value will be decreased about 66.7 73.7%.

  3. Endoscopic submucosal dissection: European Society of Gastrointestinal Endoscopy (ESGE) Guideline.

    PubMed

    Pimentel-Nunes, Pedro; Dinis-Ribeiro, Mário; Ponchon, Thierry; Repici, Alessandro; Vieth, Michael; De Ceglie, Antonella; Amato, Arnaldo; Berr, Frieder; Bhandari, Pradeep; Bialek, Andrzej; Conio, Massimo; Haringsma, Jelle; Langner, Cord; Meisner, Søren; Messmann, Helmut; Morino, Mario; Neuhaus, Horst; Piessevaux, Hubert; Rugge, Massimo; Saunders, Brian P; Robaszkiewicz, Michel; Seewald, Stefan; Kashin, Sergey; Dumonceau, Jean-Marc; Hassan, Cesare; Deprez, Pierre H

    2015-09-01

    This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). The Grading of Recommendations Assessment, Development, and Evaluation (GRADE) system 1 2 was adopted to define the strength of recommendations and the quality of evidence. 1 ESGE recommends endoscopic en bloc resection for superficial esophageal squamous cell cancers (SCCs), excluding those with obvious submucosal involvement (strong recommendation, moderate quality evidence). Endoscopic mucosal resection (EMR) may be considered in such lesions when they are smaller than 10 mm if en bloc resection can be assured. However, ESGE recommends endoscopic submucosal dissection (ESD) as the first option, mainly to provide an en bloc resection with accurate pathology staging and to avoid missing important histological features (strong recommendation, moderate quality evidence). 2 ESGE recommends endoscopic resection with a curative intent for visible lesions in Barrett's esophagus (strong recommendation, moderate quality evidence). ESD has not been shown to be superior to EMR for excision of mucosal cancer, and for that reason EMR should be preferred. ESD may be considered in selected cases, such as lesions larger than 15 mm, poorly lifting tumors, and lesions at risk for submucosal invasion (strong recommendation, moderate quality evidence). 3 ESGE recommends endoscopic resection for the treatment of gastric superficial neoplastic lesions that possess a very low risk of lymph node metastasis (strong recommendation, high quality evidence). EMR is an acceptable option for lesions smaller than 10 - 15 mm with a very low probability of advanced histology (Paris 0-IIa). However, ESGE recommends ESD as treatment of choice for most gastric superficial neoplastic lesions (strong recommendation, moderate quality evidence). 4 ESGE states that the majority of colonic and rectal superficial lesions can be effectively removed in a curative way by standard polypectomy and/or by EMR (strong recommendation, moderate quality evidence). ESD can be considered for removal of colonic and rectal lesions with high suspicion of limited submucosal invasion that is based on two main criteria of depressed morphology and irregular or nongranular surface pattern, particularly if the lesions are larger than 20 mm; or ESD can be considered for colorectal lesions that otherwise cannot be optimally and radically removed by snare-based techniques (strong recommendation, moderate quality evidence). © Georg Thieme Verlag KG Stuttgart · New York.

  4. Services for reducing duration of hospital care for acute stroke patients.

    PubMed

    2005-04-18

    Stroke patients conventionally receive a substantial part of their rehabilitation in hospital. Services have now been developed which offer patients in hospital an early discharge with rehabilitation at home (early supported discharge (ESD)). To establish the effects and costs of ESD services compared with conventional services. We searched the Cochrane Stroke Group's trials register (last searched August 2004) and obtained further information from individual trialists. Randomised controlled trials recruiting stroke patients in hospital to receive either conventional care or any service intervention which has provided rehabilitation and support in a community setting with an aim of reducing the duration of hospital care. Two reviewers scrutinised trials and categorised them on their eligibility. Standardised individual patient data was then sought from the primary trialists. Results were analysed for all trials and for subgroups of patients and services; in particular whether the intervention was provided by a co-ordinated multidisciplinary team (co-ordinated ESD team) or not. Outcome data are currently available for 11 trials (1597 patients). Patients tended to be a selected elderly group with moderate disability. The ESD group showed significant reductions (P < 0.0001) in the length of hospital stay equivalent to approximately 8 days. Overall, the odds ratios (OR) (95% confidence interval (CI)) for death, death or institutionalisation, death or dependency at the end of scheduled follow up were OR 0.90, 95% CI 0.64 to 1.27, P = 0.56, OR 0.74, 95% CI 0.56 to 0.96, P = 0.02 and OR 0.79, 95% CI 0.64 to 0.97, P = 0.02, respectively. The greatest benefits were seen in the trials evaluating a co-ordinated ESD team and in stroke patients with mild-moderate disability. Improvements were also seen in patients' extended activities of daily living scores (standardised mean difference 0.12, 95% CI 0.00 to 0.25, P = 0.05) and satisfaction with services (OR 1.60, 95% CI 1.08 to 2.38, P = 0.02) but no statistically significant differences were seen in carers' subjective health status, mood or satisfaction with services. Appropriately resourced ESD services provided for a selected group of stroke patients can reduce long term dependency and admission to institutional care as well as reducing the length of hospital stay. No adverse impact was observed on the mood or subjective health status of patients or carers.

  5. Characteristic microwave background distortions from collapsing domain wall bubbles

    NASA Technical Reports Server (NTRS)

    Goetz, Guenter; Noetzold, Dirk

    1990-01-01

    The magnitude and angular pattern of distortions of the microwave background are analyzed by collapsing spherical domain walls. A characteristic pattern of redshift distortions of red or blue spikes surrounded by blue discs was found. The width and height of a spike is related to the diameter and magnitude of the disc. A measurement of the relations between these quantities thus can serve as an unambiguous indicator for a collapsing spherical domain wall. From the redshift distortion in the blue discs an upper bound was found on the surface energy density of the walls sigma is less than or approximately 8 MeV cubed.

  6. Interferometric analysis of polishing surface with a petal tool

    NASA Astrophysics Data System (ADS)

    Salas-Sánchez, Alfonso; Leal-Cabrera, Irce; Percino Zacarias, Elizabeth; Granados-Agustín, Fermín S.

    2011-09-01

    In this work, we describe a phase shift interferometric monitoring of polishing processes produced by a petal tool over a spherical surface to obtain a parabolic surface. In the process, we used a commercial polishing machine; the purpose of this work is to have control of polishing time. To achieve this analysis, we used a Fizeau interferometer of ZYGO Company for optical shop testing, and the Durango software from Diffraction International Company. For data acquisition, simulation and evaluation of optical surfaces, we start polishing process with a spherical surface with 15.46 cm of diameter; a 59.9 cm of radius curvature and, with f/# 1.9.

  7. Development of internal magnetic probe for current density profile measurement in Versatile Experiment Spherical Torus

    NASA Astrophysics Data System (ADS)

    Yang, J.; Lee, J. W.; Jung, B. K.; Chung, K. J.; Hwang, Y. S.

    2014-11-01

    An internal magnetic probe using Hall sensors to measure a current density profile directly with perturbation of less than 10% to the plasma current is successfully operated for the first time in Versatile Experiment Spherical Torus (VEST). An appropriate Hall sensor is chosen to produce sufficient signals for VEST magnetic field while maintaining the small size of 10 mm in outer diameter. Temperature around the Hall sensor in a typical VEST plasma is regulated by blown air of 2 bars. First measurement of 60 kA VEST ohmic discharge shows a reasonable agreement with the total plasma current measured by Rogowski coil in VEST.

  8. Contribution of High-Order Rainbows to the Scattering of a Gaussian Laser Beam by a Spherical Particle

    NASA Technical Reports Server (NTRS)

    Lock, James A.

    1993-01-01

    I review the theory of the scattering of a Gaussian laser beam by a dielectric spherical particle and give the details for constructing a computer program to implement the theory. Computational results indicate that if the width of the laser beam is much less than the diameter of the particle and if the axis of the beam is incident near the edge of the particle, the fifth-, sixth-, and ninth-order rainbows should be evident in the far-field scattered intensity. I performed an experiment that yielded tentative evidence for the presence of the sixth- order rainbow.

  9. ESD/MITRE Software Acquisition Symposium Proceedings; an ESD/Industry Dialogue held in Bedford, Massachusetts on May 6-7, 1986

    DTIC Science & Technology

    1986-05-07

    Cycle? Moderator: Christine M. Anderson Dennis D. Doe Manager of Engineering Software and Artificial Intelligence Boeing Aerospace Company In... intelligence systems development pro- cess affect the life cycle? Artificial intelligence developers seem to be the last haven for people who don’t...of Engineering Software and Artificial Intelligence at the Boeing Aerospace Company. In this capacity, Mr. Doe is the focal point for software

  10. Rapid Solidification of a New Generation Aluminum-Lithium Alloy via Electrospark Deposition

    NASA Astrophysics Data System (ADS)

    Heard, David W.; Boselli, Julien; Gauvin, Raynald; Brochu, Mathieu

    Electrospark deposition (ESD) is a rapid solidification processing technique capable of depositing a metal onto a conductive substrate. The short pulse duration and high pulse frequency, combined with the small amount of material transferred during each pulse, results in high cooling rates being realized, on the order of 105-106 C/sec. This study investigates the ability to induce solute trapping behavior, for a new generation aluminum-lithium alloy, AA2199, using ESD.

  11. High Dose Proton Pump Inhibitor Infusion Versus Bolus Injection for the Prevention of Bleeding After Endoscopic Submucosal Dissection: Prospective Randomized Controlled Study.

    PubMed

    Choi, Cheol Woong; Kang, Dae Hwan; Kim, Hyung Wook; Hong, Joung Boom; Park, Su Bum; Kim, Su Jin; Cho, Mong

    2015-07-01

    A high dose of continuous intravenous infusion of proton pump inhibitor (PPI) is the standard treatment for peptic ulcer bleeding. The optimal dose for the prevention of bleeding after endoscopic submucosal dissection (ESD) is unclear. The purpose of this study was to determine whether stronger acid suppression more effectively prevents bleeding and high risk ulcer stigma (HRS) after gastric ESD. A total of 273 patients who underwent ESD were randomly assigned to one of two treatment groups: the continuous infusion group and the bolus injection group. Second-look endoscopy was performed on the following day after ESD. The incidences and risk factors of HRS identified by second-look endoscopy and delayed bleeding were analyzed. There were no differences in the incidences of HRS and delayed bleeding between two treatment groups. The incidence of HRS was 15.8 % (43/273) and the gross morphology (flat or depressed) was identified as a significant factor associated with HRS. The incidence of delayed bleeding was 8.4 % (23/273) and the gross morphology (flat) and the presence of submucosal invasive cancer were identified as the associated risk factors for delayed bleeding. The incidences of delayed bleeding and HRS identified by second-look endoscopy were not affected by PPI infusion methods. Flat or depressed morphologic lesions and submucosal invasive cancer should be closely monitored.

  12. Clinicopathological characteristics of synchronous and metachronous gastric neoplasms after endoscopic submucosal dissection

    PubMed Central

    Jang, Mi Young; Oh, Wang Guk; Ko, Sung Jun; Han, Shang Hoon; Baek, Hoon Ki; Lee, Young Jae; Kim, Ji Woong; Jung, Gum Mo; Cho, Yong Keun

    2013-01-01

    Background/Aims Endoscopic submucosal dissection (ESD) has become accepted as a minimally invasive treatment for gastric neoplasms. However, the development of synchronous or metachronous gastric lesions after endoscopic resection has become a major problem. We investigated the characteristics of multiple gastric neoplasms in patients with early gastric cancer (EGC) or gastric adenoma after ESD. Methods In total, 512 patients with EGC or gastric adenoma who had undergone ESD between January 2008 and December 2011 participated in this study. The incidence of and factors associated with synchronous and metachronous gastric tumors were investigated in this retrospective study. Results In total, 66 patients (12.9%) had synchronous lesions, and 13 patients (2.5%) had metachronous lesions. Older (> 65 years) subjects had an increased risk of multiple gastric neoplasms (p = 0.012). About two-thirds of the multiple lesions were similar in macroscopic and histological type to the primary lesions. The median interval from the initial lesions to the diagnosis of metachronous lesions was 31 months. The annual incidence rate of metachronous lesions was approximately 3%. Conclusions We recommend careful follow-up in patients of advanced age (> 65 years) after initial ESD because multiple lesions could be detected in the remnant stomach. Annual surveillance might aid in the detection of metachronous lesions. Large-scale, multicenter, and longer prospective studies of appropriate surveillance programs are needed. PMID:24307844

  13. Prenatal developmental toxicity testing of petroleum substances: Application of the mouse embryonic stem cell test (EST) to compare in vitro potencies with potencies observed in vivo.

    PubMed

    Kamelia, Lenny; Louisse, Jochem; de Haan, Laura; Rietjens, Ivonne M C M; Boogaard, Peter J

    2017-10-01

    Prenatal developmental toxicity (PDT) as observed with some petroleum substances (PS) has been associated with the presence of 3-7 ring polycyclic aromatic hydrocarbons (PAHs). In the present study, the applicability of ES-D3 cell differentiation assay of the EST to evaluate in vitro embryotoxicity potencies of PS and gas-to-liquid (GTL) products as compared to their in vivo potencies was investigated. DMSO-extracts of a range of PS, containing different amounts of PAHs, and GTL-products, which are devoid of PAHs, were tested in the ES-D3 cell proliferation and differentiation assays of the EST. The results show that PS inhibited the differentiation of ES-D3 cells into cardiomyocytes in a concentration-dependent manner at non-cytotoxic concentrations, and that their potency was proportional to their PAH content. In contrast, as expected, GTL-products did not inhibit ES-D3 cell viability or differentiation at all. The in vitro PDT potencies were compared to published in vivo PDT studies, and a good correlation was found between in vitro and in vivo results (R 2 =0.97). To conclude, our results support the hypothesis that PAHs are the primary inducers of the PDT in PS. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. The Arabidopsis E3 Ubiquitin Ligase HOS1 Negatively Regulates CONSTANS Abundance in the Photoperiodic Control of Flowering[W

    PubMed Central

    Lazaro, Ana; Valverde, Federico; Piñeiro, Manuel; Jarillo, Jose A.

    2012-01-01

    The Arabidopsis thaliana early in short days6 (esd6) mutant was isolated in a screen for mutations that accelerate flowering time. Among other developmental alterations, esd6 displays early flowering in both long- and short-day conditions. Fine mapping of the mutation showed that the esd6 phenotype is caused by a lesion in the HIGH EXPRESSION OF OSMOTICALLY RESPONSIVE GENES1 (HOS1) locus, which encodes a RING finger–containing E3 ubiquitin ligase. The esd6/hos1 mutation causes decreased FLOWERING LOCUS C expression and requires CONSTANS (CO) protein for its early flowering phenotype under long days. Moreover, CO and HOS1 physically interact in vitro and in planta, and HOS1 regulates CO abundance, particularly during the daylight period. Accordingly, hos1 causes a shift in the regular long-day pattern of expression of FLOWERING LOCUS T (FT) transcript, starting to rise 4 h after dawn in the mutant. In addition, HOS1 interacts synergistically with CONSTITUTIVE PHOTOMORPHOGENIC1, another regulator of CO protein stability, in the regulation of flowering time. Taken together, these results indicate that HOS1 is involved in the control of CO abundance, ensuring that CO activation of FT occurs only when the light period reaches a certain length and preventing precocious flowering in Arabidopsis. PMID:22408073

  15. A new data format for the commissioning phase of the ATLAS detector

    NASA Astrophysics Data System (ADS)

    Köneke, Karsten; ATLAS Collaboration

    2010-04-01

    In the commissioning phase of the ATLAS experiment, low-level Event Summary Data (ESD) are analyzed to evaluate the performance of the individual subdetectors, the performance of the reconstruction and particle identification algorithms, and to obtain calibration coefficients. In the grid model of distributed analysis, these data must be transferred to Tier-1 and Tier-2 sites before they can be analyzed. However, the large size of ESD (approxeq1 MByte/event) constrains the amount of data that can be distributed on the grid and is available on disks. In order to overcome this constraint and make the data fully available, new data sets — collectively known as Derived Physics Data (DPD) — have been designed. Each DPD set contains a subset of the ESD data, tailored to specific needs of the subdetector and object reconstruction and identification performance groups. Filtering algorithms perform a selection based on physics contents and trigger response, further reducing the data volume. Thanks to these techniques, the total volume of DPD to be distributed on the grid amounts to 20% of the initial ESD data. An evolution of the tools developed in this context serves to produce another set of DPDs that are specifically tailored for physics analysis. All selection criteria and other relevant information is stored inside these DPDs as meta-data and a connection to external databases is also established.

  16. Endoscopic submucosal dissection of early colorectal neoplasms with a monopolar scissor-type knife: short- to long-term outcomes.

    PubMed

    Kuwai, Toshio; Yamaguchi, Toshiki; Imagawa, Hiroki; Sumida, Yuki; Takasago, Takeshi; Miyasako, Yuki; Nishimura, Tomoyuki; Iio, Sumio; Yamaguchi, Atsushi; Kouno, Hirotaka; Kohno, Hiroshi; Ishaq, Sauid

    2017-09-01

    Background and study aims  Endoscopic submucosal dissection (ESD) for colorectal neoplasms remains challenging because of technical issues imposed by the complex anatomical features of the large intestine. We evaluated the feasibility, and the short- and long-term clinical outcomes of ESD for early colorectal neoplasms performed using the Stag-beetle Knife Jr. (SB Knife Jr.) Patients and methods  We retrospectively assessed 228 patients who underwent ESD for 247 colorectal lesions with the SB Knife Jr. Clinicopathological characteristics of the neoplasms, complications, and various short- and long-term outcomes were evaluated. Results  Mean tumor size was 34.3 mm and median procedure time was 76 minutes. The SB Knife Jr. achieved 98.4 % en bloc resection, 93.9 % complete resection, and 85.4 % curative resection. No perforations occurred during the procedure, and a delayed bleeding rate of 2.4 % was observed. Long-term outcomes were favorable with no distant recurrence, 1.1 % local recurrence, a 5-year overall survival rate of 94.1 % and 5-year tumor-specific survival rate of 98.6 % in patients with cancer. Conclusions  ESD using the SB Knife Jr. is technically efficient and safe in treating early colorectal neoplasms and is associated with favorable short- and long-term outcomes. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Partial differential equation methods for stochastic dynamic optimization: an application to wind power generation with energy storage.

    PubMed

    Johnson, Paul; Howell, Sydney; Duck, Peter

    2017-08-13

    A mixed financial/physical partial differential equation (PDE) can optimize the joint earnings of a single wind power generator (WPG) and a generic energy storage device (ESD). Physically, the PDE includes constraints on the ESD's capacity, efficiency and maximum speeds of charge and discharge. There is a mean-reverting daily stochastic cycle for WPG power output. Physically, energy can only be produced or delivered at finite rates. All suppliers must commit hourly to a finite rate of delivery C , which is a continuous control variable that is changed hourly. Financially, we assume heavy 'system balancing' penalties in continuous time, for deviations of output rate from the commitment C Also, the electricity spot price follows a mean-reverting stochastic cycle with a strong evening peak, when system balancing penalties also peak. Hence the economic goal of the WPG plus ESD, at each decision point, is to maximize expected net present value (NPV) of all earnings (arbitrage) minus the NPV of all expected system balancing penalties, along all financially/physically feasible future paths through state space. Given the capital costs for the various combinations of the physical parameters, the design and operating rules for a WPG plus ESD in a finite market may be jointly optimizable.This article is part of the themed issue 'Energy management: flexibility, risk and optimization'. © 2017 The Author(s).

  18. Environmental Sciences Division annual progress report for period ending September 30, 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-04-01

    This progress report summarizes the research and development activities conducted in the Environmental Sciences Division of Oak Ridge National Laboratory during the period October 1, 1990, through September 30, 1991. The report is structured to provide descriptions of current activities and accomplishments in each of the division's major organizational units. Following the sections describing the organizational units is a section devoted to lists of information necessary to convey the scope of the work in the division. The Environmental Sciences Division (ESD) at Oak Ridge National Laboratory (ORNL) conducts environmental research and analyses associated with both energy technology development and themore » interactions between people and the environment. The division engages in basic and applied research for a diverse list of sponsors. While the US Department of Energy (DOE) is the primary sponsor ESD staff also perform research for other federal agencies, state agencies, and private industry. The division works collaboratively with federal agencies, universities, and private organizations in achieving its research objectives and hosts a large number of visiting investigators from these organizations. Given the diverse interdisciplinary specialization of its staff, ESD provides technical expertise on complex environmental problems and renders technical leadership for major environmental issues of national and local concern. This progress report highlights many of ESD's accomplishment in these and other areas in FY 1991.« less

  19. Defect Implosion Experiments (DIME) at OMEGA

    NASA Astrophysics Data System (ADS)

    Cobble, J. A.; Schmitt, M. J.; Tregillis, I. L.; Obrey, K. D.; Magelssen, G. R.; Wilke, M. D.; Glebov, V.; Marshall, F. J.; Kim, Y. H.; Bradley, P. A.; Batha, S. H.

    2010-11-01

    The Los Alamos DIME campaign involves perturbed spherical implosions, driven by 60 OMEGA beams with uniform, symmetrical illumination. D-T-filled CH-shell targets with equatorial-plane defects are designed to produce a non-spherical neutron burn region. The objectives of the DIME series are to observe the non-spherical burn with the neutron imaging system (NIS) and to simulate the physics of the neutron and x-ray production. We have demonstrated adequate neutron yield for NIS imaging with targets of diameter 860 μm. All targets are filled with 5 atm of DT. We used two separate shell thicknesses: 8 μm and 15 μm, thus testing both exploding pusher and ablative designs. Defect channel depth ranges from 0 -- 8 μm. Width is 20 -- 40 μm. Perfect targets have no defect. Numerical simulations predict enhanced x-ray emission, that is suggested by experiment. Results from a recent DIME campaign will be discussed.

  20. Linearized T-Matrix and Mie Scattering Computations

    NASA Technical Reports Server (NTRS)

    Spurr, R.; Wang, J.; Zeng, J.; Mishchenko, M. I.

    2011-01-01

    We present a new linearization of T-Matrix and Mie computations for light scattering by non-spherical and spherical particles, respectively. In addition to the usual extinction and scattering cross-sections and the scattering matrix outputs, the linearized models will generate analytical derivatives of these optical properties with respect to the real and imaginary parts of the particle refractive index, and (for non-spherical scatterers) with respect to the ''shape'' parameter (the spheroid aspect ratio, cylinder diameter/height ratio, Chebyshev particle deformation factor). These derivatives are based on the essential linearity of Maxwell's theory. Analytical derivatives are also available for polydisperse particle size distribution parameters such as the mode radius. The T-matrix formulation is based on the NASA Goddard Institute for Space Studies FORTRAN 77 code developed in the 1990s. The linearized scattering codes presented here are in FORTRAN 90 and will be made publicly available.

  1. Application of an ultrasonic focusing radiator for acoustic levitation of submillimeter samples

    NASA Technical Reports Server (NTRS)

    Lee, M. C.

    1981-01-01

    An acoustic apparatus has been specifically developed to handle samples of submillimeter size in a gaseous medium. This apparatus consists of an acoustic levitation device, deployment devices for small liquid and solid samples, heat sources for sample heat treatment, acoustic alignment devices, a cooling system and data-acquisition instrumentation. The levitation device includes a spherical aluminum dish of 12 in. diameter and 0.6 in. thickness, 130 pieces of PZT transducers attached to the back side of the dish and a spherical concave reflector situated in the vicinity of the center of curvature of the dish. The three lowest operating frequencies for the focusing-radiator levitation device are 75, 105 and 163 kHz, respectively. In comparison with other levitation apparatus, it possesses a large radiation pressure and a high lateral positional stability. This apparatus can be used most advantageously in the study of droplets and spherical shell systems, for instance, for fusion target applications.

  2. Surgical and healing changes to ocular aberrations following refractive surgery

    NASA Astrophysics Data System (ADS)

    Straub, Jochen; Schwiegerling, Jim

    2003-07-01

    Purpose: To measure ocular aberrations before and at several time periods after LASIK surgery to determine the change to the aberration structure of the eye. Methods: A Shack-Hartmann wavefront sensor was used to measure 88 LASIK patients pre-operatively and at 1 week and 12 months following surgery. Reconstructed wavefront errors are compared to look at induced differences. Manifest refraction was measured at 1 week, 1 month, 3 months, 6 months and 12 months following surgery. Sphere, cylinder, spherical aberration, and pupil diameter are analyzed. Results: A dramatic elevation in spherical aberration is seen following surgery. This elevation appears almost immediately and remains for the duration of the study. A temporary increase in pupil size is seen following surgery. Conclusions: LASIK surgery dramatically reduces defocus and astigmatism in the eye, but simultaneously increases spherical aberration levels. This increase occurs at the time of surgery and is not an effect of the healing response.

  3. Confinement dynamics of a semiflexible chain inside nano-spheres

    NASA Astrophysics Data System (ADS)

    Fathizadeh, A.; Heidari, Maziar; Eslami-Mossallam, B.; Ejtehadi, M. R.

    2013-07-01

    We study the conformations of a semiflexible chain, confined in nano-scaled spherical cavities, under two distinct processes of confinement. Radial contraction and packaging are employed as two confining procedures. The former method is performed by gradually decreasing the diameter of a spherical shell which envelopes a confined chain. The latter procedure is carried out by injecting the chain inside a spherical shell through a hole on the shell surface. The chain is modeled with a rigid body molecular dynamics simulation and its parameters are adjusted to DNA base-pair elasticity. Directional order parameter is employed to analyze and compare the confined chain and the conformations of the chain for two different sizes of the spheres are studied in both procedures. It is shown that for the confined chains in the sphere sizes of our study, they appear in spiral or tennis-ball structures, and the tennis-ball structure is more likely to be observed in more compact confinements. Our results also show that the dynamical procedure of confinement and the rate of the confinement are influential parameters of the structure of the chain inside spherical cavities.

  4. Does immunohistochemical staining have a clinical impact in early gastric cancer conducted endoscopic submucosal dissection?

    PubMed Central

    Jeon, Seong Ran; Cho, Joo Young; Bok, Gene Hyun; Lee, Tae Hee; Kim, Hyun Gun; Cho, Won Young; Jin, So Young; Kim, Yeon Soo

    2012-01-01

    AIM: To evaluate clinicopathologic parameters and the clinical significance related lymphovascular invasion (LVI) by immunohistochemical staining (IHCS) in endoscopic submucosal dissection (ESD). METHODS: Between May 2005 and May 2010, a total of 348 lesions from 321 patients (mean age 63 ± 10 years, men 74.6%) with early gastric cancer (EGC) who met indication criteria after ESD were analyzed retrospectively. The 348 lesions were divided into the absolute (n = 100, differentiated mucosal cancer without ulcer ≤ 20 mm) and expanded (n = 248) indication groups after ESD. The 248 lesions were divided into four subgroups according to the expanded ESD indication. The presence of LVI was determined by factor VIII-related antigen and D2-40 assessment. We compared LVI IHCS-negative group with LVI IHCS-positive in each group. RESULTS: LVI by hematoxylin-eosin staining (HES) and IHCS were all negative in the absolute group, while was observed in only the expanded groups. The positive rate of LVI by IHCS was higher than that of LVI by HES (n = 1, 0.4% vs n = 11, 4.4%, P = 0.044). LVI IHCS-positivity was observed when the cancer invaded to the mucosa 3 (M3) or submucosa 1 (SM1) levels, with a predominance of 63.6% in the subgroup that included only SM1 cancer (P < 0.01). In a univariate analysis, M3 or SM1 invasion by the tumor was significantly associated with a higher rate of LVI by IHCS, but no factor was significant in a multivariate analysis. There were no cases of tumor recurrence or metastasis during the median 26 mo follow-up. CONCLUSION: EGCs of the absolute group are immunohistochemically stable. The presence of LVI may be carefully examined by IHCS in an ESD expanded indication group with an invasion depth of M3 or greater. PMID:22969232

  5. Endoscopic submucosal dissection for early Barrett’s neoplasia

    PubMed Central

    Barret, Maximilien; Cao, Dalhia Thao; Beuvon, Frédéric; Leblanc, Sarah; Terris, Benoit; Camus, Marine; Coriat, Romain; Chaussade, Stanislas

    2015-01-01

    Introduction The possible benefit of endoscopic submucosal dissection (ESD) for early neoplasia arising in Barrett’s esophagus remains controversial. We aimed to assess the efficacy and safety of ESD for the treatment of early Barrett’s neoplasia. Methods All consecutive patients undergoing ESD for the resection of a visible lesion in a Barrett’s esophagus, either suspicious of submucosal infiltration or exceeding 10 mm in size, between February 2012 and January 2015 were prospectively included. The primary endpoint was the rate of curative resection of carcinoma, defined as histologically complete resection of adenocarcinomas without poor histoprognostic factors. Results Thirty-five patients (36 lesions) with a mean age of 66.2 ± 12 years, a mean ASA score of 2.1 ± 0.7, and a mean C4M6 Barrett’s segment were included. The mean procedure time was 191 ± 79 mn, and the mean size of the resected specimen was 51.3 ± 23 mm. En bloc resection rate was 89%. Lesions were 12 ± 15 mm in size, and 81% (29/36) were invasive adenocarcinomas, six of which with submucosal invasion. Although R0 resection of carcinoma was 72.4%, the curative resection rate was 66% (19/29). After a mean follow-up of 12.9 ± 9 months, 16 (45.7%) patients had required additional treatment, among whom nine underwent surgical resection, and seven further endoscopic treatments. Metachronous lesions or recurrence of cancer developed during the follow-up period in 17.2% of the patients. The overall complication rate was 16.7%, including 8.3% perforations, all conservatively managed, and no bleeding. The 30-day mortality was 0%. Conclusion In this early experience, ESD yielded a moderate curative resection rate in Barrett’s neoplasia. At present, improvements are needed if ESD is to replace piecemeal endoscopic mucosal resection in the management of Barrett’s neoplasia. PMID:27087948

  6. Endoscopic submucosal dissection for early Barrett's neoplasia.

    PubMed

    Barret, Maximilien; Cao, Dalhia Thao; Beuvon, Frédéric; Leblanc, Sarah; Terris, Benoit; Camus, Marine; Coriat, Romain; Chaussade, Stanislas; Prat, Frédéric

    2016-04-01

    The possible benefit of endoscopic submucosal dissection (ESD) for early neoplasia arising in Barrett's esophagus remains controversial. We aimed to assess the efficacy and safety of ESD for the treatment of early Barrett's neoplasia. All consecutive patients undergoing ESD for the resection of a visible lesion in a Barrett's esophagus, either suspicious of submucosal infiltration or exceeding 10 mm in size, between February 2012 and January 2015 were prospectively included. The primary endpoint was the rate of curative resection of carcinoma, defined as histologically complete resection of adenocarcinomas without poor histoprognostic factors. Thirty-five patients (36 lesions) with a mean age of 66.2 ± 12 years, a mean ASA score of 2.1 ± 0.7, and a mean C4M6 Barrett's segment were included. The mean procedure time was 191 ± 79 mn, and the mean size of the resected specimen was 51.3 ± 23 mm. En bloc resection rate was 89%. Lesions were 12 ± 15 mm in size, and 81% (29/36) were invasive adenocarcinomas, six of which with submucosal invasion. Although R0 resection of carcinoma was 72.4%, the curative resection rate was 66% (19/29). After a mean follow-up of 12.9 ± 9 months, 16 (45.7%) patients had required additional treatment, among whom nine underwent surgical resection, and seven further endoscopic treatments. Metachronous lesions or recurrence of cancer developed during the follow-up period in 17.2% of the patients. The overall complication rate was 16.7%, including 8.3% perforations, all conservatively managed, and no bleeding. The 30-day mortality was 0%. In this early experience, ESD yielded a moderate curative resection rate in Barrett's neoplasia. At present, improvements are needed if ESD is to replace piecemeal endoscopic mucosal resection in the management of Barrett's neoplasia.

  7. Efficacy and complication of endoscopic submucosal dissection for superficial esophageal carcinoma: a systematic review and meta-analysis

    PubMed Central

    2014-01-01

    Aim For patients with superficial esophageal carcinoma, ESD was one of treatment modalities to remove the lesion safely and effectively. We perform this meta-analysis to determine the efficacy and incidence of complication of ESD for patients with superficial esophageal carcinoma. Method Articles were searched in MEDLINE (PubMed and Ovid), Cochrane Database of Systemic Reviews, Google scholar, and Web of Science. Two reviewers independently searched and extracted data. Meta-analysis of the efficacy of ESD was analyzed by calculating pooled en bloc and R0 resection rate. Incidence of complications such as perforation, stenosis and mediastinal emphysema was also calculated. Pooling was conducted using either fixed-effects model or random-effects model depending on the heterogeneity across studies. Results 21 studies (1152 patients and 1240 lesions) were included in this analysis. The pooled en bloc resection rate was 99% (95% CI 99%-100%). Stratified by tumor size, en bloc resection rates did not show any significant difference. The pooled R0 resection rate was 90% (95% CI 87%-93%). The pooled R0 resection rate was 85% (95% CI, 80%-90%) for large tumor and 92% (95% CI, 87%-93%) for small tumor (p < 0.001). Stenosis served as the most common reported complication with pooled incidence of 5% (95% CI 3-8%), followed by perforation (1%, 95% CI 0-1%) and mediastinal emphysema (0% CI 0-1%). The incidence of postoperative stenosis decreased significantly after 2011 (2%, 95% CI 0-3%) compared with that before 2011 (9%, 95% CI 3-8%) (p < 0.001). Conclusion ESD was an efficient modality for treating superficial esophageal carcinoma, with perfect en bloc and R0 resection rate and low complication rate. The most common complication of ESD was stenosis. Although recurrence rate was low, patients should be maintained in a scheduled surveillance program. PMID:24885614

  8. Generation of extreme state of water by spherical wire array underwater electrical explosion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Antonov, O.; Gilburd, L.; Efimov, S.

    2012-10-15

    The results of the first experiments on the underwater electrical explosion of a spherical wire array generating a converging strong shock wave are reported. Using a moderate pulse power generator with a stored energy of {<=}6 kJ and discharge current of {<=}500 kA with a rise-time of {approx}300 ns, explosions of Cu and Al wire arrays of different diameters and with a different number and diameter of wires were tested. Electrical, optical, and destruction diagnostics were used to determine the energy deposited into the array, the time-of-flight of the shock wave to the origin of the implosion, and the parametersmore » of water at that location. The experimental and numerical simulation results indicate that the convergence of the shock wave leads to the formation of an extreme state of water in the vicinity of the implosion origin that is characterized by pressure, temperature, and compression factors of (2 {+-} 0.2) Multiplication-Sign 10{sup 12} Pa, 8 {+-} 0.5 eV, and 7 {+-} 0.5, respectively.« less

  9. Pressurant requirements for discharge of liquid methane from a 1.52-meter-(5-ft-) diameter spherical tank under both static and slosh conditions

    NASA Technical Reports Server (NTRS)

    Dewitt, R. L.; Mcintire, T. O.

    1974-01-01

    Pressurized expulsion tests were conducted to determine the effect of various physical parameters on the pressurant gas (methane, helium, hydrogen, and nitrogen) requirements during the expulsion of liquid methane from a 1.52-meter-(5-ft-) diameter spherical tank and to compare results with those predicted by an analytical program. Also studied were the effects on methane, helium, and hydrogen pressurant requirements of various slosh excitation frequencies and amplitudes, both with and without slosh suppressing baffles in the tank. The experimental results when using gaseous methane, helium, and hydrogen show that the predictions of the analytical program agreed well with the actual pressurant requirements for static tank expulsions. The analytical program could not be used for gaseous nitrogen expulsions because of the large quantities of nitrogen which can dissolve in liquid methane. Under slosh conditions, a pronounced increase in gaseous methane requirements was observed relative to results obtained for the static tank expulsions. Slight decreases in the helium and hydrogen requirements were noted under similar test conditions.

  10. Influence of hydrothermal processing on functional properties and grain morphology of finger millet.

    PubMed

    Dharmaraj, Usha; Meera, M S; Reddy, S Yella; Malleshi, Nagappa G

    2015-03-01

    Finger millet was hydrothermally processed followed by decortication. Changes in color, diameter, density, sphericity, thermal and textural characteristics and also some of the functional properties of the millet along with the grain morphology of the kernels after hydrothermal processing and decortication were studied. It was observed that, the millet turned dark after hydrothermal processing and color improved over native millet after decortication. A slight decrease in grain diameter was observed but sphericity of the grains increased on decortication. The soft and fragile endosperm turned into a hard texture and grain hardness increased by about 6 fold. Hydrothermal processing increased solubility and swelling power of the millet at ambient temperature. Pasting profile indicated that, peak viscosity decreased significantly on hydrothermal processing and both hydrothermally processed and decorticated millet exhibited zero breakdown viscosity. Enthalpy was negative for hydrothermally processed millet and positive for decorticated grains. Microscopic studies revealed that the orderly structure of endosperm changed to a coherent mass after hydrothermal processing and the different layers of seed coat get fused with the endosperm.

  11. Single macroscopic pillars as model system for bioinspired adhesives: influence of tip dimension, aspect ratio, and tilt angle.

    PubMed

    Micciché, Maurizio; Arzt, Eduard; Kroner, Elmar

    2014-05-28

    The goal of our study is to better understand the design parameters of bioinspired dry adhesives inspired by geckos. For this, we fabricated single macroscopic pillars of 400 μm diameter with different aspect ratios and different tip shapes (i.e., flat tips, spherical tips with different radii, and mushroom tips with different diameters). Tilt-angle-dependent adhesion measurements showed that although the tip shape of the pillars strongly influences the pull-off force, the pull-off strength is similar for flat and mushroom-shaped tips. We found no tilt-angle dependency of adhesion for spherical tip structures and, except for high tilt angle and low preload experiments, no tilt-angle effect for mushroom-tip pillars. For flat-tip pillars, we found a strong influence of tilt angle on adhesion, which decreased linearly with increasing aspect ratio. The experiments show that for the tested aspect ratios between 1 and 5, a linear decrease of tilt-angle dependency is found. The results of our studies will help to design bioinspired adhesives for application on smooth and rough surfaces.

  12. Self-assembled clusters of spheres related to spherical codes.

    PubMed

    Phillips, Carolyn L; Jankowski, Eric; Marval, Michelle; Glotzer, Sharon C

    2012-10-01

    We consider the thermodynamically driven self-assembly of spheres onto the surface of a central sphere. This assembly process forms self-limiting, or terminal, anisotropic clusters (N-clusters) with well-defined structures. We use Brownian dynamics to model the assembly of N-clusters varying in size from two to twelve outer spheres and free energy calculations to predict the expected cluster sizes and shapes as a function of temperature and inner particle diameter. We show that the arrangements of outer spheres at finite temperatures are related to spherical codes, an ideal mathematical sequence of points corresponding to the densest possible sphere packings. We demonstrate that temperature and the ratio of the diameters of the inner and outer spheres dictate cluster morphology. We present a surprising result for the equilibrium structure of a 5-cluster, for which the square pyramid arrangement is preferred over a more symmetric structure. We show this result using Brownian dynamics, a Monte Carlo simulation, and a free energy approximation. Our results suggest a promising way to assemble anisotropic building blocks from constituent colloidal spheres.

  13. Fibrous structure in GaSb surfaces irradiated with fast Cu cluster ions

    NASA Astrophysics Data System (ADS)

    Tsuchida, Hidetsugu; Nitta, Noriko; Yanagida, Yusuke; Okumura, Yuya; Murase, Ryu

    2018-04-01

    The effect of fast cluster irradiation on the formation of fibrous structures is investigated for single crystal GaSb surfaces irradiated by Cun+ ions (n = 1-3) with an energy of 0.4 MeV/atom at ion fluences up to 5 × 1015 cm-2. We study the cluster size dependence on the growth of fibrous network structures. With increasing cluster size, the shape of the fiber changed from rod-like to spherical. To quantitatively evaluate this cluster effect, a fiber diameter d in rod or spherical portion is examined as a function of ion fluence Φ and cluster size n. We find that the fiber diameter nonlinearly increases and follows the relation d ∝nα×Φ , with α≈2 . This evidently implies that the amount of defects generated by n-sized cluster bombardments varies as n2 for n ≤3 . Cluster ion irradiation enhances the defect generation owing to the overlap between cascades of individual cluster constituents and is therefore effective for the growth of nanofibers.

  14. Mimas: Tectonic structure and geologic history

    NASA Technical Reports Server (NTRS)

    Croft, Steven K.

    1991-01-01

    Mimas, the innermost of the major saturnian satellites, occupies an important place in comparative studies of icy satellites. It is the smallest icy satellite known to have a mostly spherical shape. Smaller icy objects like Hyperion and Puck are generally irregular in shape, while larger ones like Miranda and Enceladus are spherical. Thus Mimas is near the diameter where the combination of increasing surface gravity and internal heating begin to have a significant effect on global structure. The nature and extent of endogenic surface features provide important constraints on the interior structure and history of this transitional body. The major landforms on Mimas are impact craters. Mimas has one of the most heavily cratered surfaces in the solar system. The most prominent single feature on Mimas is Herschel, an unrelaxed complex crater 130 km in diameter. The only other recognized landforms on Mimas are tectonic grooves and lineaments. Groove locations were mapped by Schenk, but without analysis of groove structures or superposition relationships. Mimas' tectonic structures are remapped here in more detail than previously has been done, as part of a general study of tectonic features on icy satellites.

  15. Formation of polymer nanoparticles by UV pulsed laser ablation of poly (bisphenol A carbonate) in liquid environment

    NASA Astrophysics Data System (ADS)

    Martínez-Tong, Daniel E.; Sanz, Mikel; Ezquerra, Tiberio A.; Nogales, Aurora; Marco, José F.; Castillejo, Marta; Rebollar, Esther

    2017-10-01

    Suspensions of poly(bisphenol A carbonate) (PBAC) nanoparticles of varying size and shape have been produced by ablation of a PBAC target in liquid media with the fourth harmonic of a Q-switched Nd:YAG laser (wavelength 266 nm, full width at half maximum 4 ns, repetition rate 10 Hz). The polymer target was placed at the bottom of a rotating glass vessel filled with around a 10 mm column of liquid. Laser ablation in water leads to spherical nanoparticles with diameters of several tens of nanometers for fluences close to 1 J/cm2. Ablation at lower fluences, around 0.1 J/cm2, results in the production of nanoparticles of smaller diameters and also of non-spherical nanoparticles. Additional irradiations at the fluence of 0.1 J/cm2 were performed in several liquid media with different properties, in terms of density, viscosity, thermal conductivity, boiling temperature, isothermal compressibility and polarity. The different size distributions observed were related to the thermal conductivity of the systems, while their viscosity seems to be responsible for the development of nanostructures with different morphologies.

  16. Effect of scattering on coherent anti-Stokes Raman scattering (CARS) signals.

    PubMed

    Ranasinghesagara, Janaka C; De Vito, Giuseppe; Piazza, Vincenzo; Potma, Eric O; Venugopalan, Vasan

    2017-04-17

    We develop a computational framework to examine the factors responsible for scattering-induced distortions of coherent anti-Stokes Raman scattering (CARS) signals in turbid samples. We apply the Huygens-Fresnel wave-based electric field superposition (HF-WEFS) method combined with the radiating dipole approximation to compute the effects of scattering-induced distortions of focal excitation fields on the far-field CARS signal. We analyze the effect of spherical scatterers, placed in the vicinity of the focal volume, on the CARS signal emitted by different objects (2μm diameter solid sphere, 2μm diameter myelin cylinder and 2μm diameter myelin tube). We find that distortions in the CARS signals arise not only from attenuation of the focal field but also from scattering-induced changes in the spatial phase that modifies the angular distribution of the CARS emission. Our simulations further show that CARS signal attenuation can be minimized by using a high numerical aperture condenser. Moreover, unlike the CARS intensity image, CARS images formed by taking the ratio of CARS signals obtained using x- and y-polarized input fields is relatively insensitive to the effects of spherical scatterers. Our computational framework provide a mechanistic approach to characterizing scattering-induced distortions in coherent imaging of turbid media and may inspire bottom-up approaches for adaptive optical methods for image correction.

  17. Effect of scattering on coherent anti-Stokes Raman scattering (CARS) signals

    PubMed Central

    Ranasinghesagara, Janaka C.; De Vito, Giuseppe; Piazza, Vincenzo; Potma, Eric O.; Venugopalan, Vasan

    2017-01-01

    We develop a computational framework to examine the factors responsible for scattering-induced distortions of coherent anti-Stokes Raman scattering (CARS) signals in turbid samples. We apply the Huygens-Fresnel wave-based electric field superposition (HF-WEFS) method combined with the radiating dipole approximation to compute the effects of scattering-induced distortions of focal excitation fields on the far-field CARS signal. We analyze the effect of spherical scatterers, placed in the vicinity of the focal volume, on the CARS signal emitted by different objects (2μm diameter solid sphere, 2μm diameter myelin cylinder and 2μm diameter myelin tube). We find that distortions in the CARS signals arise not only from attenuation of the focal field but also from scattering-induced changes in the spatial phase that modifies the angular distribution of the CARS emission. Our simulations further show that CARS signal attenuation can be minimized by using a high numerical aperture condenser. Moreover, unlike the CARS intensity image, CARS images formed by taking the ratio of CARS signals obtained using x- and y-polarized input fields is relatively insensitive to the effects of spherical scatterers. Our computational framework provide a mechanistic approach to characterizing scattering-induced distortions in coherent imaging of turbid media and may inspire bottom-up approaches for adaptive optical methods for image correction. PMID:28437941

  18. Study Of Dose Distribution In A Human Body In Space Flight With The Spherical Tissue-Equivalent Phantom

    NASA Astrophysics Data System (ADS)

    Shurshakov, Vyacheslav; Akatov, Yu; Petrov, V.; Kartsev, I.; Polenov, Boris; Petrov, V.; Lyagushin, V.

    In the space experiment MATROSHKA-R, the spherical tissue equivalent phantom (30 kg mass, 35 cm diameter and 10 cm central spherical cave) made in Russia has been installed in the star board crew cabin of the ISS Service Module. Due to the specially chosen phantom shape and size, the chord length distributions of the detector locations are attributed to self-shielding properties of the critical organs in a real human body. If compared with the anthropomorphic phantom Rando used inside and outside the ISS, the spherical phantom has lower mass, smaller size, and requires less crew time for the detector retrieval; its tissue-equivalent properties are closer to the standard human body tissue than the Rando-phantom material. In the first phase of the experiment the dose measurements were realized with only passive detectors (thermoluminescent and solid state track detectors). There were two experimental sessions with the spherical phantom in the crew cabin, (1) from Jan. 29, 2004 to Apr. 30, 2004 and (2) from Aug. 11, 2004 to Oct. 10, 2005. The detectors are placed inside the phantom along the axes of 20 containers and on the phantom outer surface in 32 pockets of the phantom jacket. The results obtained with the passive detectors returned to the ground after each session show the dose difference on the phantom surface as much as a factor of 2, the highest dose being observed close to the outer wall of the crew cabin, and the lowest dose being in the opposite location along the phantom diameter. Maximum dose rate measured in the phantom (0.31 mGy/day) is obviously due to the galactic cosmic ray (GCR) and Earth' radiation belt contribution on the ISS trajectory. Minimum dose rate (0.15 mGy/day) is caused mainly by the strongly penetrating GCR particles and is observed behind more than 5 g/cm2 tissue shielding. Critical organ doses, mean-tissue and effective doses of a crew member in the crew cabin are also estimated with the spherical phantom. The estimated effective dose rate (about 0.49 mSv/day at radiation quality factor of 2.6) is from 12 to 15 per cent lower than the averaged dose on the phantom surface as dependent on the body attitude.

  19. Computer numerically controlled (CNC) aspheric shaping with toroidal Wheels (Abstract Only)

    NASA Astrophysics Data System (ADS)

    Ketelsen, D.; Kittrell, W. C.; Kuhn, W. M.; Parks, R. E.; Lamb, George L.; Baker, Lynn

    1987-01-01

    Contouring with computer numerically controlled (CNC) machines can be accomplished with several different tool geometries and coordinated machine axes. To minimize the number of coordinated axes for nonsymmetric work to three, it is common practice to use a spherically shaped tool such as a ball-end mill. However, to minimize grooving due to the feed and ball radius, it is desirable to use a long ball radius, but there is clearly a practical limit to ball diameter with the spherical tool. We have found that the use of commercially available toroidal wheels permits long effective cutting radii, which in turn improve finish and minimize grooving for a set feed. In addition, toroidal wheels are easier than spherical wheels to center accurately. Cutting parameters are also easier to control because the feed rate past the tool does not change as the slope of the work changes. The drawback to the toroidal wheel is the more complex calculation of the tool path. Of course, once the algorithm is worked out, the tool path is as easily calculated as for a spherical tool. We have performed two experiments with the Large Optical Generator (LOG) that were ideally suited to three-axis contouring--surfaces that have no axis of rotational symmetry. By oscillating the cutting head horizontally or vertically (in addition to the motions required to generate the power of the surface) , and carefully coordinating those motions with table rotation, the mostly astigmatic departure for these surfaces is produced. The first experiment was a pair of reflector molds that together correct the spherical aberration of the Arecibo radio telescope. The larger of these was 5 m in diameter and had a 12 cm departure from the best-fit sphere. The second experiment was the generation of a purely astigmatic surface to demonstrate the feasibility of producing axially symmetric asphe.rics while mounted and rotated about any off-axis point. Measurements of the latter (the first experiment had relatively loose tolerances) indicate an accuracy only 3 or 4 times that achieved by conventional two-axis contouring (10 AM as opposed to 3 pm rms) The successful completion of these projects demonstrates the successful application of three-axis contouring with the LOG. Toroidal cutters have also solved many of the drawbacks of spherical wheels. Work remains to be done in improving machine response and decreasing the contribution of backlash errors.

  20. Comparison between the effects of positive noncatastrophic HMB ESD stress in n-channel and p-channel power MOSFET's

    NASA Astrophysics Data System (ADS)

    Zupac, Dragan; Kosier, Steven L.; Schrimpf, Ronald D.; Galloway, Kenneth F.; Baum, Keith W.

    1991-10-01

    The effect of noncatastrophic positive human body model (HBM) electrostatic discharge (ESD) stress on n-channel power MOSFETs is radically different from that on p-channel MOSFETs. In n-channel transistors, the stress causes negative shifts of the current-voltage characteristics indicative of positive charge trapping in the gate oxide. In p-channel transistors, the stress increases the drain-to-source leakage current, probably due to localized avalanche electron injection from the p-doped drain.

Top