Sample records for spherical equivalent se

  1. Anisometropia of spherical equivalent and astigmatism among myopes: a 23-year follow-up study of prevalence and changes from childhood to adulthood.

    PubMed

    Pärssinen, Olavi; Kauppinen, Markku

    2017-08-01

    To study anisometropia of spherical equivalent and astigmatism from the onset of myopia at school age to adulthood. A total of 240 myopic schoolchildren (mean age 10.9 years), with no previous spectacles, were recruited during 1983-1984 to a randomized 3-year clinical trial of bifocal treatment of myopia. Examinations with subjective cyclopedic refraction were repeated 3 years later (follow-up 1) for 238 subjects and thereafter at the mean ages of 23.2 (follow-up 2) and 33.9 years (follow-up 3) for 178 and 134 subjects. After exclusions, the 102 subjects who attended all three follow-ups were included in the analyses. Corneal refractive power and astigmatism and anterior chamber depth was measured with Pentacam topography and axial length with IOL master at study end. Prevalence and changes in anisometropia of spherical equivalent (AnisoSE) and astigmatism (AnisoAST) and their relationships with refractive and axial measures were studied. Mean (±SD) of spherical equivalent (SE), AnisoSE and AnisoAST increased from baseline to follow-up end from -1.44 ± 0.57 D to -5.11 ± 2.23 D, from 0.28 ± 0.30 D to 0.68 ± 0.69 D and from 0.14 ± 0.18 D to 0.37 ± 0.36 D, respectively. Prevalence of AnioSE, ≥1 D, increased from 5% to 22.6% throughout follow-up. Higher AnisoSE was associated with SE in the less myopic eye at baseline and at follow-up 1, and with SE in the more myopic eye in follow-ups 2 and 3 in adulthood. At study end, AnisoSE was associated with the interocular difference in axial length (AL) (r = 0.612, p < 0.001) but not with the interocular difference in corneal refraction (CR) (r = -0.122, p = 0.266). In cases of low AnisoSE(≤1.00 D), the negative correlation between the real interocular differences (value of right eye minus value of left eye) in CR and AL (r = -0.427, p < 0.001) decreased the influence of the interocular difference in AL on AnisoSE, causing emmetropization in AnisoSE. The interocular difference in corneal astigmatism was the main factor associated with AnisoAST (r = 0.231, p = 0.020). No significant relationship was found between AnisoAST and level of SE. Anisometropia of the spherical equivalent (AnisoSE) increased along with the myopic progression and at study end was mainly associated with the interocular difference in AL. AnisoAST was mainly explained by the interocular difference in corneal astigmatism. In cases with low AnisoSE (≤1.0 D), the interrelationship between CR and AL decreased AnisoSE causing emmetropization in AnisoSE. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  2. Patient satisfaction and acceptance of spherical equivalent spectacles correction wear in rural India.

    PubMed

    Reddy, B Sandeep; Das, Taraprasad; Mirdha, Ghansyam S; Reddy, Nagavardhan

    2017-08-01

    The aim of this study was to explore the possibilities of acceptance of a ready-to-dispense spherical equivalent (SE) of spherocylindrical (SC) correction spectacles in rural India. Snellen visual acuity with SE power of refracted SC lenses was prospectively collected from all individuals visiting vision centers in Phase 1 (vision correction accuracy) of the study conducted in two South Indian districts. The satisfaction level was recorded by asking one standard question. The SE spectacles were dispensed in vision centers of one district in Phase 2 (SE acceptance) with a suggestion to return, if unsatisfied, for free exchange of spectacles within a month of dispensing. In Phase 1, 929 of 3529 patients were refracted and it was found that 320 patients and one eye of one patient (641 eyes) had astigmatism. The average age was 41 (±16; range: 7-84) years. There was no reduction of visual acuity in SE of 0.25 Dcyl (100% satisfaction) and progressive decrease in satisfaction to 43%, 26%, and 19% with SE correction of 0.50, 0.75, and 1.00 Dcyl, respectively. In Phase 2, 988 of 6168 patients needed refraction and 240 had astigmatism. A total of 103 patients (206 eyes) accepted SE equivalent spectacles. No client returned for the free exchange of spectacles. Dispensing SE power up to 1 Dcyl in ready - made spectacles could be considered in remote rural populations in resource-poor economic conditions.

  3. Genetic effects on refraction and correlation with hemodynamic variables: a twin study.

    PubMed

    Toth, G Zs; Tarnoki, Adam Domonkos; Tarnoki, D L; Racz, A; Szekelyhidi, Z; Littvay, L; Karlinger, K; Lannert, A; Molnar, A A; Garami, Zs; Berczi, V; Suveges, I; Nemeth, J

    2014-09-01

    Spherical equivalent (SE) has not been linked to increased cardiovascular morbidity. Methods: 132 Hungarian twins(age 43.3±16.9 years) underwent refraction measurements (Huvitz MRK-3100 Premium AutoRefractokeratometer)and oscillometry (TensioMed Arteriograph). Results: Heritability analysis indicated major role for genetic components in the presence of right and left SE (82.7%, 95%CI, 62.9 to 93.7%, and 89.3%, 95%CI, 72.8 to 96.6%),while unshared environmental effects accounted for 17% (95%CI, 6.3% to 37%), and 11% (95%CI, 3.4% to 26.7%)of variations adjusted for age and sex. Bilateral SE showed weak age-dependent correlations with augmentation index (AIx), aortic pulse wave velocity (r ranging between 0.218 and 0.389, all p < 0.01), aortic systolic blood pressure and pulse pressure (r between 0.188 and 0.289, p < 0.05). Conclusions: These findings support heritability of spherical equivalent, which does not coexist with altered hemodynamics (e.g. accelerated arterial aging).Accordingly, SE and the investigated hemodynamic parameters seem neither phenotypically nor genetically associated.

  4. Anisometropia of ocular refractive and biometric measures among 66- to 79-year-old female twins.

    PubMed

    Pärssinen, Olavi; Kauppinen, Markku; Kaprio, Jaakko; Rantanen, Taina

    2016-12-01

    To examine the prevalence of anisometropia of spherical refraction (AnisoSR), astigmatism (AnisoAST) and spherical equivalent (AnisoSE) and their associations with spherical refraction (SR), refractive astigmatism (AST), spherical equivalent (SE) and interocular differences of ocular biometric parameters among elderly female twins. Refraction of 117 monozygotic (MZ) and 116 dizygotic (DZ) female twin subjects aged 66-79 years was assessed with an auto-refractor (Topcon AT) and controlled by subjective refraction. Corneal refraction, anterior chamber depth and axial length were measured with a Zeiss IOL Master. Participants with eyes operated for cataract or glaucoma were excluded, but the grade of nuclear opacity was not recorded. The associations between the absolute values of AnisoSR, AnisoAST and AnisoSE with SR, AST, SE, corneal refractive power (CR), corneal astigmatism (CAST), anterior chamber depth (ACD) and axial length (AL) and with their interocular differences were calculated. When calculating the interdependencies of the differences, the real and absolute differences between the right and left eye were used. Means ± standard deviations for AnisoSR, AnisoAST and AnisoSE were 0.67 ± 0.92 D, 0.42 ± 0.41 D and 0.65 ± 0.71 D, respectively. AnisoSR, AnisoAST and AnisoSE >1.0 D were present in 14.7%, 4.2% and 17.7% of cases, respectively. Anisometropia of spherical refraction (AnisoSR), AnisoAST and AnisoSE were higher the more negative the values of SR or SE. Hyperopic ametropia did not increase these anisometropia values. The correlations of AnisoSR and AnisoSE with the absolute values of interocular differences in CR and AL were non-significant. Using the real values of the interocular differences, the respective correlations were significant. The correlation between the real interocular differences in CR and AL was negative (r = -0.258, p < 0.001). Thus, the combined effect of the real interocular differences in CR and AL was a decrease in AnisoSR and AnisoSE (emmetropization). Higher AnisoSR and AnisoSE were associated with more myopic refraction and longer AL. Higher AnisoAST was associated with more negative SR and higher AST and CAST. The negative correlation between real interocular differences in CR and AL indicated their influence of emmetropization in AnisoSR and AnisoSE. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  5. Association of Axial Length With Risk of Uncorrectable Visual Impairment for Europeans With Myopia.

    PubMed

    Tideman, J Willem L; Snabel, Margaretha C C; Tedja, Milly S; van Rijn, Gwyneth A; Wong, King T; Kuijpers, Robert W A M; Vingerling, Johannes R; Hofman, Albert; Buitendijk, Gabriëlle H S; Keunen, Jan E E; Boon, Camiel J F; Geerards, Annette J M; Luyten, Gregorius P M; Verhoeven, Virginie J M; Klaver, Caroline C W

    2016-12-01

    Myopia (ie, nearsightedness) is becoming the most common eye disorder to cause blindness in younger persons in many parts of the world. Visual impairment due to myopia is associated with structural changes of the retina and the globe because of elongation of the eye axis. How axial length-a sum of the anterior chamber depth, lens thickness, and vitreous chamber depth-and myopia relate to the development of visual impairment over time is unknown. To evaluate the association between axial length, spherical equivalent, and the risk of visual impairment and to make projections of visual impairment for regions with high prevalence rates. This cross-sectional study uses population-based data from the Rotterdam Study I (1990 to 1993), II (2000 to 2002), and III (2006 to 2008) and the Erasmus Rucphen Family Study (2002 to 2005) as well as case-control data from the Myopia Study (2010 to 2012) from the Netherlands. In total, 15 404 individuals with data on spherical equivalent and 9074 individuals with data on axial length were included in the study; right eyes were used for analyses. Data were analyzed from September 2014 to May 2016. Visual impairment and blindness (defined according to the World Health Organization criteria as a visual acuity less than 0.3) and predicted rates of visual impairment specifically for persons with myopia. Of the 15 693 individuals included in this study, the mean (SD) age was 61.3 (11.4) years, and 8961 (57.1%) were female. Axial length ranged from 15.3 to 37.8 mm; 819 individuals had an axial length of 26 mm or greater. Spherical equivalent ranged from -25 to +14 diopters; 796 persons had high myopia (ie, a spherical equivalent of -6 diopters or less). The prevalence of visual impairment varied from 1.0% to 4.1% in the population-based studies, was 5.4% in the Myopia Study, and was 0.3% in controls. The prevalence of visual impairment rose with increasing axial length and spherical equivalent, with a cumulative incidence (SE) of visual impairment of 3.8% (1.3) for participants aged 75 years with an axial length of 24 to less than 26 mm and greater than 90% (8.1) with an axial length of 30 mm or greater. The cumulative risk (SE) of visual impairment was 5.7% (1.3) for participants aged 60 years and 39% (4.9) for those aged 75 years with a spherical equivalent of -6 diopters or less. Projections of these data suggest that visual impairment will increase 7- to 13-fold by 2055 in high-risk areas. This study demonstrated that visual impairment is associated with axial length and spherical equivalent and may be unavoidable at the most extreme values in this population. Developing strategies to prevent the development of myopia and its complications could help to avoid an increase of visual impairment in the working-age population.

  6. Difference of refraction values between standard autorefractometry and Plusoptix.

    PubMed

    Bogdănici, Camelia Margareta; Săndulache, Codrina Maria; Vasiliu, Rodica; Obadă, Otilia

    2016-01-01

    Aim: Comparison between the objective refraction measurement results determined with Topcon KR-8900 standard autorefractometer and Plusoptix A09 photo-refractometer in children. Material and methods: A prospective transversal study was performed in the Department of Ophthalmology of "Sf. Spiridon" Hospital in Iași on 90 eyes of 45 pediatric patients, with a mean age of 8,82 ± 3,52 years, examined with noncycloplegic measurements provided by Plusoptix A09 and cycloplegic and noncycloplegic measurements provided by Topcon KR-8900 standard autorefractometer. The clinical parameters compared were the following: spherical equivalent (SE), spherical and cylindrical values, and cylinder axis. Astigmatism was recorded and evaluated with the cylindrical value on minus after transposition. The statistical calculation was performed with paired t-tests and Pearson's correlation analysis. All the data were analyzed with SPSS statistical package 19 (SPSS for Windows, Chicago, IL). Results: Plusoptix A09 noncycloplegic values were relatively equal between the eyes, with slightly lower values compared to noncycloplegic auto refractometry. Mean (± SD) measurements provided by Plusoptix AO9 were the following: spherical power 1.11 ± 1.52, cylindrical power 0.80 ± 0.80, and spherical equivalent 0.71 ± 1.39. The noncycloplegic auto refractometer mean (± SD) measurements were spherical power 1.12 ± 1.63, cylindrical power 0.79 ± 0,77 and spherical equivalent 0.71 ± 1.58. The cycloplegic auto refractometer mean (± SD) measurements were spherical power 2.08 ± 1.95, cylindrical power 0,82 ± 0.85 and spherical equivalent 1.68 ± 1.87. 32% of the eyes were hyperopic, 2.67% were myopic, 65.33% had astigmatism, and 30% eyes had amblyopia. Conclusions: Noncycloplegic objective refraction values were similar with those determined by autorefractometry. Plusoptix had an important role in the ophthalmological screening, but did not detect higher refractive errors, justifying the cycloplegic autorefractometry.

  7. Autorefraction versus subjective refraction in a radially asymmetric multifocal intraocular lens.

    PubMed

    van der Linden, Jan Willem; Vrijman, Violette; Al-Saady, Rana; El-Saady, Rana; van der Meulen, Ivanka J; Mourits, Maarten P; Lapid-Gortzak, Ruth

    2014-12-01

    To evaluate whether the automated refraction (AR) correlates with subjective manifest (MR) refraction in eyes implanted with radially asymmetric multifocal intraocular lens (IOLs). This retrospective study evaluated 52 eyes (52 patients) implanted with a radially asymmetric multifocal IOL (LS-312 MF30, Oculentis, Germany). At 3 months postoperatively, the AR and MR values were compared to determine the correlation between the sphere (S), the spherical equivalent (SE) and the astigmatic components J0 and J45. The difference of mean spherical measurement was +0.98D ± 0.62, with the AR measuring more myopic. The difference of the mean spherical equivalent was +1.11D ± 0.57, again with AR being more myopic. Both these differences were statistically significant (p < 0.001). The astigmatic components showed less differences, with the mean difference of the J0 being -0.09D ± 0.43, and the J45 of +0.04D ± 0.47, which were both not statistically significant (p = 0.123 and p = 0.531, respectively). Correlation analysis of the refractive parameters showed r(2) = 0.067, r(2) = 0.078, r(2) = 0.018 and r(2) = 0.015, respectively, all of which point to a low correlation between the AR and the MR. Autorefraction shows poor correlation to manifest subjective refraction with these radially asymmetric multifocal IOLs. The autorefraction systematically underestimates the spherical and spherical equivalent power, while the correlation between the astigmatic components was also low. Autorefraction seems not a valid starting point for manifest subjective refraction with these types of lenses, unless a corrective factor of about +1 dioptre is used. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  8. Associations of Anisometropia with Unilateral Amblyopia, Interocular Acuity Difference and Stereoacuity in Preschoolers

    PubMed Central

    Ying, Gui-shuang; Huang, Jiayan; Maguire, Maureen; Quinn, Graham; Kulp, Marjean Taylor; Ciner, Elise; Cyert, Lynn; Orel-Bixler, Deborah

    2012-01-01

    Purpose To evaluate the relation of anisometropia with unilateral amblyopia, interocular acuity difference (IAD) and stereoacuity, among Head Start preschoolers, using both clinical notation and vector notation analyses. Design Multicenter, cross-sectional study. Participants 3- to 5-year-old participants in the Vision In Preschoolers (VIP) Study (N=4040). Methods Secondary analysis of VIP data from participants who had comprehensive eye examinations including monocular visual acuity (VA) testing, stereoacuity testing, and cycloplegic refraction. VA was retested with full cycloplegic correction when retest criteria were met. Unilateral amblyopia was defined as IAD ≥2 lines in logarithm of the Minimum Angle of Resolution (logMAR). Anisometropia was defined as ≥0.25 D (diopter) difference in spherical equivalent (SE) or in cylinder power, and also two approaches using power vector notation. The percentage with unilateral amblyopia, mean IAD, and mean stereoacuity were compared between anisometropic and isometropic children. Main Outcomes Measures The percentage with unilateral amblyopia, mean IAD, and mean stereoacuity. Results Compared with isometropic children, anisometropic children had a higher percentage of unilateral amblyopia (8% vs. 2%), larger mean IAD (0.07 vs. 0.05 logMAR) and worse mean stereoacuity (145 vs.117 arc sec) (all p<0.0001). Larger amounts of anisometropia were associated with higher percentages of unilateral amblyopia, larger IAD, and worse stereoacuity (trend p<0.001). Percentage of unilateral amblyopia was significantly increased with spherical equivalent (SE) anisometropia >0.5 D, cylindrical anisometropia >0.25 D, the vertical/horizontal meridian (J0) or oblique meridian (J45) >0.125 D, or vector dioptric distance (VDD) >0.35 D (all p<0.001). VDD had higher ability in detecting unilateral amblyopia than cylinder, SE, J0 and J45 (p<0.001). Conclusions The presence of and amount of anisometropia were associated with the presence of unilateral amblyopia, larger IAD and worse stereoacuity. The threshold level of anisometropia at which unilateral amblyopia becomes significant was lower than current guidelines. VDD is more accurate than spherical equivalent anisometropia or cylindrical anisometropia in identifying preschoolers with unilateral amblyopia. PMID:23174398

  9. Non-cycloplegic spherical equivalent refraction in adults: comparison of the double-pass system, retinoscopy, subjective refraction and a table-mounted autorefractor.

    PubMed

    Vilaseca, Meritxell; Arjona, Montserrat; Pujol, Jaume; Peris, Elvira; Martínez, Vanessa

    2013-01-01

    To evaluate the accuracy of spherical equivalent (SE) estimates of a double-pass system and to compare it with retinoscopy, subjective refraction and a table-mounted autorefractor. Non-cycloplegic refraction was performed on 125 eyes of 65 healthy adults (age 23.5±3.0 years) from October 2010 to January 2011 using retinoscopy, subjective refraction, autorefraction (Auto kerato-refractometer TOPCON KR-8100, Japan) and a double-pass system (Optical Quality Analysis System, OQAS, Visiometrics S.L., Spain). Nine consecutive measurements with the double-pass system were performed on a subgroup of 22 eyes to assess repeatability. To evaluate the trueness of the OQAS instrument, the SE laboratory bias between the double-pass system and the other techniques was calculated. The SE mean coefficient of repeatability obtained was 0.22D. Significant correlations could be established between the OQAS and the SE obtained with retinoscopy (r=0.956, P<0.001), subjective refraction (r=0.955, P<0.001) and autorefraction (r=0.957, P<0.001). The differences in SE between the double-pass system and the other techniques were significant (P<0.001), but lacked clinical relevance except for retinoscopy; Retinoscopy gave more hyperopic values than the double-pass system -0.51±0.50D as well as the subjective refraction -0.23±0.50D; More myopic values were achieved by means of autorefraction 0.24±0.49D. The double-pass system provides accurate and reliable estimates of the SE that can be used for clinical studies. This technique can determine the correct focus position to assess the ocular optical quality. However, it has a relatively small measuring range in comparison with autorefractors (-8.00 to +5.00D), and requires prior information on the refractive state of the patient.

  10. Non-cycloplegic spherical equivalent refraction in adults: comparison of the double-pass system, retinoscopy, subjective refraction and a table-mounted autorefractor

    PubMed Central

    Vilaseca, Meritxell; Arjona, Montserrat; Pujol, Jaume; Peris, Elvira; Martínez, Vanessa

    2013-01-01

    AIM To evaluate the accuracy of spherical equivalent (SE) estimates of a double-pass system and to compare it with retinoscopy, subjective refraction and a table-mounted autorefractor. METHODS Non-cycloplegic refraction was performed on 125 eyes of 65 healthy adults (age 23.5±3.0 years) from October 2010 to January 2011 using retinoscopy, subjective refraction, autorefraction (Auto kerato-refractometer TOPCON KR-8100, Japan) and a double-pass system (Optical Quality Analysis System, OQAS, Visiometrics S.L., Spain). Nine consecutive measurements with the double-pass system were performed on a subgroup of 22 eyes to assess repeatability. To evaluate the trueness of the OQAS instrument, the SE laboratory bias between the double-pass system and the other techniques was calculated. RESULTS The SE mean coefficient of repeatability obtained was 0.22D. Significant correlations could be established between the OQAS and the SE obtained with retinoscopy (r=0.956, P<0.001), subjective refraction (r=0.955, P<0.001) and autorefraction (r=0.957, P<0.001). The differences in SE between the double-pass system and the other techniques were significant (P<0.001), but lacked clinical relevance except for retinoscopy; Retinoscopy gave more hyperopic values than the double-pass system -0.51±0.50D as well as the subjective refraction -0.23±0.50D; More myopic values were achieved by means of autorefraction 0.24±0.49D. CONCLUSION The double-pass system provides accurate and reliable estimates of the SE that can be used for clinical studies. This technique can determine the correct focus position to assess the ocular optical quality. However, it has a relatively small measuring range in comparison with autorefractors (-8.00 to +5.00D), and requires prior information on the refractive state of the patient. PMID:24195036

  11. The prevalence of refractive conditions in Puerto Rican adults attending an eye clinic system

    PubMed Central

    Rodriguez, Neisha M.; Romero, Angel. F.

    2014-01-01

    Purpose To determine the prevalence of refractive conditions in the adult population that visited primary care optometry clinics in Puerto Rico. Methods A retrospective cross-sectional study of patients examined at the Inter American University of Puerto Rico School of Optometry Eye Institute Clinics between 2004 and 2010. Subjects considered had best corrected visual acuity by standardized subjective refraction of 20/40 or better. The refractive errors were classified by the spherical equivalent (SE): sphere+½ cylinder. Myopia was classified as a SE>−0.50 D, hyperopia as a SE>+0.50  D, and emmetropia as a SE between −0.50 and +0.50, both included. Astigmatism equal or higher than 0.25 D in minus cylinder form was used. Patients with documented history of cataract extraction (pseudophakia or aphakia), amblyopia, refractive surgery or other corneal/ocular surgery were excluded from the study. Results A total of 784 randomly selected subjects older than 40 years of age were selected. The estimated prevalence (95%, confidence interval) among all subjects was hyperopia 51.5% (48.0–55.0), emmetropia 33.8% (30.5–37.2), myopia 14.7% (12.1–17.2) and astigmatism 69.6% (68.8–73.3). Hyperopia was more common in females than males although the difference was not statistically significant. The mean spherical equivalent values was hyperopic until 70 y/o and decreased slightly as the population ages. Conclusion Hyperopia is the most common refractive error and its prevalence and seems to increase among the aging population who visited the clinics. Further programs and studies must be developed to address the refractive errors needs of the adult Puerto Rican population. PMID:25000872

  12. Association between Refractive Errors and Ocular Biometry in Iranian Adults

    PubMed Central

    Hashemi, Hassan; Khabazkhoob, Mehdi; Emamian, Mohammad Hassan; Shariati, Mohammad; Miraftab, Mohammad; Yekta, Abbasali; Ostadimoghaddam, Hadi; Fotouhi, Akbar

    2015-01-01

    Purpose: To investigate the association between ocular biometrics such as axial length (AL), anterior chamber depth (ACD), lens thickness (LT), vitreous chamber depth (VCD) and corneal power (CP) with different refractive errors. Methods: In a cross-sectional study on the 40 to 64-year-old population of Shahroud, random cluster sampling was performed. Ocular biometrics were measured using the Allegro Biograph (WaveLight AG, Erlangen, Germany) for all participants. Refractive errors were determined using cycloplegic refraction. Results: In the first model, the strongest correlations were found between spherical equivalent with axial length and corneal power. Spherical equivalent was strongly correlated with axial length in high myopic and high hyperopic cases, and with corneal power in high hyperopic cases; 69.5% of variability in spherical equivalent was attributed to changes in these variables. In the second model, the correlations between vitreous chamber depth and corneal power with spherical equivalent were stronger in myopes than hyperopes, while the correlations between lens thickness and anterior chamber depth with spherical equivalent were stronger in hyperopic cases than myopic ones. In the third model, anterior chamber depth + lens thickness correlated with spherical equivalent only in moderate and severe cases of hyperopia, and this index was not correlated with spherical equivalent in moderate to severe myopia. Conclusion: In individuals aged 40-64 years, corneal power and axial length make the greatest contribution to spherical equivalent in high hyperopia and high myopia. Anterior segment biometric components have a more important role in hyperopia than myopia. PMID:26730304

  13. New Objective Refraction Metric Based on Sphere Fitting to the Wavefront

    PubMed Central

    Martínez-Finkelshtein, Andreí

    2017-01-01

    Purpose To develop an objective refraction formula based on the ocular wavefront error (WFE) expressed in terms of Zernike coefficients and pupil radius, which would be an accurate predictor of subjective spherical equivalent (SE) for different pupil sizes. Methods A sphere is fitted to the ocular wavefront at the center and at a variable distance, t. The optimal fitting distance, topt, is obtained empirically from a dataset of 308 eyes as a function of objective refraction pupil radius, r0, and used to define the formula of a new wavefront refraction metric (MTR). The metric is tested in another, independent dataset of 200 eyes. Results For pupil radii r0 ≤ 2 mm, the new metric predicts the equivalent sphere with similar accuracy (<0.1D), however, for r0 > 2 mm, the mean error of traditional metrics can increase beyond 0.25D, and the MTR remains accurate. The proposed metric allows clinicians to obtain an accurate clinical spherical equivalent value without rescaling/refitting of the wavefront coefficients. It has the potential to be developed into a metric which will be able to predict full spherocylindrical refraction for the desired illumination conditions and corresponding pupil size. PMID:29104804

  14. New Objective Refraction Metric Based on Sphere Fitting to the Wavefront.

    PubMed

    Jaskulski, Mateusz; Martínez-Finkelshtein, Andreí; López-Gil, Norberto

    2017-01-01

    To develop an objective refraction formula based on the ocular wavefront error (WFE) expressed in terms of Zernike coefficients and pupil radius, which would be an accurate predictor of subjective spherical equivalent (SE) for different pupil sizes. A sphere is fitted to the ocular wavefront at the center and at a variable distance, t . The optimal fitting distance, t opt , is obtained empirically from a dataset of 308 eyes as a function of objective refraction pupil radius, r 0 , and used to define the formula of a new wavefront refraction metric (MTR). The metric is tested in another, independent dataset of 200 eyes. For pupil radii r 0 ≤ 2 mm, the new metric predicts the equivalent sphere with similar accuracy (<0.1D), however, for r 0 > 2 mm, the mean error of traditional metrics can increase beyond 0.25D, and the MTR remains accurate. The proposed metric allows clinicians to obtain an accurate clinical spherical equivalent value without rescaling/refitting of the wavefront coefficients. It has the potential to be developed into a metric which will be able to predict full spherocylindrical refraction for the desired illumination conditions and corresponding pupil size.

  15. [Analysis of the influence factors of school-age children's refractive status].

    PubMed

    Chen, Z G; Chen, M C; Zhang, J Y; Cai, D Q; Wang, Q; Lin, S S; Chen, J W; Zhong, H L

    2016-11-11

    Objective: To analyze the influence of the eye biological parameters, height, and weight on the school-age children's refractive status. Methods: Cross-sectional study. A total of 1 656 children (1 656 eyes), aged from 7 to 14 years, were selected from 8 schools in Wenzhou during June 2012 and June 2013. The height and weight of each child were measured, and the body mass index (BMI) was calculated. The eye biological parameters, including axial length (AL), corneal power (C=1/CR), anterior chamber depth (ACD), and white to white (WTW), were measured by IOLMaster (version 5.0, Carl Zeiss, Germany), and the AL/CR was calculated. Refraction was measured by fast cycloplegic retinoscopy, and the spherical equivalent (SE) was calculated. Only right eyes were included in the analysis. SPSS16.0 was used to analyze the data. The correlations of the equivalent spherical power, the eye biological parameters, height, weight, and BMI were evaluated. Linear regression analysis was used for the SE, AL, and AL/CR. Results: The prevalence of myopia in 7- to 14-year-old school-age children was 50.2% on the average, 48.4% in boys, and 51.7% in girls. The average SE was (-1.07±1.74) D. With adjustment of the age, gender, urban and rural areas, there was an association between the SE and AL, AL/CR, ACD, height and weight. The correlation coefficient was -0.663, -0.730, -0.416, -0.365, and -0.281, respectively ( P< 0.05). There was no significant correlation between the SE and WTW, corneal power and BMI. Regarding the different refractive statuses, there was a stronger correlation between the SE and AL, AL/CR in children with hyperopia, moderate myopia or high myopia than those with emmetropia or mild myopia ( P< 0.01). In the older children, the correlation between the SE and AL, AL/CR was stronger. Linear regression analysis showed SE= 26.55-9.11·AL/CR and 23.0-1.02·AL. Conclusions: There was an association between the SE and AL, AL/CR, ACD, height and weight in school-age children. In children with hyperopia, moderate myopia, high myopia or at an older age, the correlation was more significant between the SE and AL, AL/CR. (Chin J Ophthalmol, 2016, 52:831-835) .

  16. Refractive Errors in Patients with Migraine Headache.

    PubMed

    Gunes, Alime; Demirci, Seden; Tok, Levent; Tok, Ozlem; Koyuncuoglu, Hasan; Yurekli, Vedat Ali

    2016-01-01

    To evaluate refractive errors in patients with migraine headache and to compare with healthy subjects. This prospective case-control study includes patients with migraine and age- and sex-matched healthy subjects. Clinical and demographic characteristics of the patients were noted. Detailed ophthalmological examinations were performed containing spherical refractive error, astigmatic refractive error, spherical equivalent (SE), anisometropia, best-corrected visual acuity, intraocular pressure, slit lamp biomicroscopy, fundus examination, axial length, anterior chamber depth, and central corneal thickness. Spectacle use in migraine and control groups was compared. Also, the relationship between refractive components and migraine headache variables was investigated. Seventy-seven migraine patients with mean age of 33.27 ± 8.84 years and 71 healthy subjects with mean age of 31.15 ± 10.45 years were enrolled (p = 0.18). The migraine patients had higher degrees of astigmatic refractive error, SE, and anisometropia when compared with the control subjects (p = 0.01, p = 0.03, p = 0.02, respectively). Migraine patients may have higher degrees of astigmatism, SE, and anisometropia. Therefore, they should have ophthalmological examinations regularly to ensure that their refractive errors are appropriately corrected.

  17. The Comparison of Regional RNFL and Fundus Vasculature by OCTA in Chinese Myopia Population.

    PubMed

    Li, Yuanjun; Miara, Hamza; Ouyang, Pingbo; Jiang, Bing

    2018-01-01

    To determine the correlations between peripapillary vessel density, retinal nerve fibre layer (RNFL) thickness, and myopic indices at retina quadrants with optical coherence tomography angiography (OCTA) in Chinese. Fifty-six subjects with a mean spherical equivalent (MSE) of -3.63 ± 0.29 D were included. Peripapillary RNFL thickness and retinal vessel density in four sectors (superior, nasal, inferior, and temporal quadrants) were determined by OCTA, and correlations of the main outcomes were analyzed. Negative correlations were found between the peripapillary RNFL thickness and axial length (AL) at superior ( r = -0.335, P = 0.001) and inferior ( r = -0.551, P < 0.001) quadrants. There was a significant positive correlation with spherical equivalent (SE) at the corresponding quadrants as well as at the nasal quadrant ( r = 0.339, P = 0.001; r = 0.379, P < 0.001; and r = 0.209, P = 0.039, resp.). Peripapillary retinal vessel density was also negatively correlated with AL at the nasal quadrant ( r = -0.392, P < 0.001), and only at the nasal quadrant, there was a positive correlation between the peripapillary vessel density and SE ( r = 0.319, P = 0.001). The degree of myopia and elongation of AL were negatively correlated with peripapillary RNFL thickness at superior and inferior quadrants and with peripapillary retinal vessel density at the nasal quadrant.

  18. The Comparison of Regional RNFL and Fundus Vasculature by OCTA in Chinese Myopia Population

    PubMed Central

    2018-01-01

    Purpose To determine the correlations between peripapillary vessel density, retinal nerve fibre layer (RNFL) thickness, and myopic indices at retina quadrants with optical coherence tomography angiography (OCTA) in Chinese. Methods Fifty-six subjects with a mean spherical equivalent (MSE) of −3.63 ± 0.29 D were included. Peripapillary RNFL thickness and retinal vessel density in four sectors (superior, nasal, inferior, and temporal quadrants) were determined by OCTA, and correlations of the main outcomes were analyzed. Results Negative correlations were found between the peripapillary RNFL thickness and axial length (AL) at superior (r = −0.335, P = 0.001) and inferior (r = −0.551, P < 0.001) quadrants. There was a significant positive correlation with spherical equivalent (SE) at the corresponding quadrants as well as at the nasal quadrant (r = 0.339, P = 0.001; r = 0.379, P < 0.001; and r = 0.209, P = 0.039, resp.). Peripapillary retinal vessel density was also negatively correlated with AL at the nasal quadrant (r = −0.392, P < 0.001), and only at the nasal quadrant, there was a positive correlation between the peripapillary vessel density and SE (r = 0.319, P = 0.001). Conclusions The degree of myopia and elongation of AL were negatively correlated with peripapillary RNFL thickness at superior and inferior quadrants and with peripapillary retinal vessel density at the nasal quadrant. PMID:29651341

  19. Role of preoperative cycloplegic refraction in LASIK treatment of hyperopia.

    PubMed

    Frings, Andreas; Steinberg, Johannes; Druchkiv, Vasyl; Linke, Stephan J; Katz, Toam

    2016-07-01

    Previous studies have suggested that, to improve refractive predictability in hyperopic LASIK treatments, preoperative cycloplegic or manifest refraction, or a combination of both, could be used in the laser nomogram. We set out to investigate (1) the prevalence of a high difference between manifest and cycloplegic spherical equivalent in hyperopic eyes preoperatively, and (2) the related predictability of postoperative keratometry. Retrospective cross-sectional data analysis of consecutive treated 186 eyes from 186 consecutive hyperopic patients (mean age 42 [±12] years) were analyzed. Excimer ablation for all eyes was performed using a mechanical microkeratome (SBK, Moria, France) and an Allegretto excimer laser platform. Two groups were defined according to the difference between manifest and cycloplegic spherical equivalent which was defined as ≥1.00 diopter (D); the data was analyzed according to refractive outcome in terms of refractive predictability, efficacy, and safety. In 24 eyes (13 %), a preoperative difference of ≥1.00D between manifest spherical equivalent and cycloplegic spherical equivalent (= MCD) occurred. With increasing preoperative MCD, the postoperative achieved spherical equivalent showed hyperopic regression after 3 months. There was no statistically significant effect of age (accommodation) or optical zone size on the achieved spherical equivalent. A difference of ≥1.00D occurs in about 13 % of hyperopia cases. We suggest that hyperopic correction should be based on the manifest spherical equivalent in eyes with preoperative MCD <1.00D. If the preoperative MCD is ≥1.00D, treatment may produce manifest undercorrection, and therefore we advise that the patient should be warrned about lower predictability, and suggest basing conclusions on the arithmetic mean calculated from the preoperative manifest and cycloplegic spheres.

  20. Theory and application of equivalent transformation relationships between plane wave and spherical wave

    NASA Astrophysics Data System (ADS)

    Wang, Yao; Yang, Zailin; Zhang, Jianwei; Yang, Yong

    2017-10-01

    Based on the governing equations and the equivalent models, we propose an equivalent transformation relationships between a plane wave in a one-dimensional medium and a spherical wave in globular geometry with radially inhomogeneous properties. These equivalent relationships can help us to obtain the analytical solutions of the elastodynamic issues in an inhomogeneous medium. The physical essence of the presented equivalent transformations is the equivalent relationships between the geometry and the material properties. It indicates that the spherical wave problem in globular geometry can be transformed into the plane wave problem in the bar with variable property fields, and its inverse transformation is valid as well. Four different examples of wave motion problems in the inhomogeneous media are solved based on the presented equivalent relationships. We obtain two basic analytical solution forms in Examples I and II, investigate the reflection behavior of inhomogeneous half-space in Example III, and exhibit a special inhomogeneity in Example IV, which can keep the traveling spherical wave in constant amplitude. This study implies that our idea makes solving the associated problem easier.

  1. Planning for Coupling Effects in Bitoric Mixed Astigmatism Ablative Treatments.

    PubMed

    Alpins, Noel; Ong, James K Y; Stamatelatos, George

    2017-08-01

    To demonstrate how to determine the historical coupling adjustments of bitoric mixed astigmatism ablative treatments and how to use these historical coupling adjustments to adjust future bitoric treatments. The individual coupling adjustments of the myopic and hyperopic cylindrical components of a bitoric treatment were derived empirically from a retrospective study where the theoretical combined treatment effect on spherical equivalent was compared to the actual change in refractive spherical equivalent. The coupling adjustments that provided the best fit in both mean and standard deviation were determined to be the historical coupling adjustments. Theoretical treatments that incorporated the historical coupling adjustments were then calculated. The actual distribution of postoperative spherical equivalent errors was compared to the theoretically adjusted distribution. The study group comprised 242 eyes and included 118 virgin right eyes and 124 virgin left eyes of 155 individuals. For the laser used, the myopic coupling adjustment was -0.02 and the hyperopic coupling adjustment was 0.30, as derived by global nonlinear optimization. This implies that almost no adjustment of the myopic component of the bitoric treatment is necessary, but that the hyperopic component of the bitoric treatment generates a large amount of unintended spherical shift. The theoretically adjusted treatments targeted zero mean spherical equivalent error, as intended, and the distribution of the theoretical spherical equivalent errors had the same spread as the distribution of actual postoperative spherical equivalent errors. Bitoric mixed astigmatism ablative treatments may display non-trivial coupling effects. Historical coupling adjustments should be taken into consideration when planning mixed astigmatism treatments to improve surgical outcomes. [J Refract Surg. 2017;33(8):545-551.]. Copyright 2017, SLACK Incorporated.

  2. Refractive errors and refractive development in premature infants.

    PubMed

    Ozdemir, O; Tunay, Z Ozen; Acar, D Erginturk; Acar, U

    2015-12-01

    To examine refractive errors and refractive development in premature infants. Premature infants in the retinopathy of prematurity (ROP) screening program were recruited and examined longitudinally between 28 and 58 weeks postmenstrual age. For performing cycloplegic retinoscopy, 1% tropicamide was administered, two drops with a 10-minute interval, in order to paralyze accommodation and to achieve cycloplegia. Birth weight, gestational age, gender and acute ROP disease were recorded. The relationship between spherical equivalent, astigmatism and postmenstrual age was evaluated. A total of 798 readings were obtained from 258 infants (131 females, 127 males) between 28 and 58 weeks postmenstrual age. The median number of examinations was 3 (minimum 1, maximum 7). In the comparisons of birth weight, gestational age, spherical equivalent and astigmatism between genders, there were no statistically significant differences (P>0.05). Gestational age (regression analysis, r(2)=0.30, P<0.01) and birth weight (regression analysis, r(2)=0.22, P<0.01) had a significant effect on refractive error development. Preterm babies with lower birth weight and those born more prematurely had lower spherical equivalent. The spherical equivalent of the eyes correlated significantly with the postmenstrual age of the infants (r=0.512, P<0.01). Infants with low gestational age and low birth weight also had low spherical equivalent. Moreover, spherical equivalent correlated with increasing postmenstrual age. However, astigmatism did not correlate with postmenstrual age and did not associate with gestational age or birth weight. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  3. Continuous form-dependent focusing of non-spherical microparticles in a highly diluted suspension with the help of microfluidic spirals

    NASA Astrophysics Data System (ADS)

    Roth, Tanja; Sprenger, Lisa; Odenbach, Stefan; Häfeli, Urs O.

    2018-04-01

    Microfluidic spirals are able to focus non-spherical microparticles in diluted suspension due to the Dean effect. A secondary flow establishes in a curved channel, consisting of two counter-rotating vortices, which transport particles to an equilibrium position near the inner wall of the channel. The relevant size parameter, which is responsible for successful focusing, is the ratio between the particle diameter of a sphere and the hydraulic diameter, which is a characteristic of the microfluidic spiral. A non-spherical particle has not one but several different size parameters. This study investigated the minor and major axes, the equivalent spherical diameter, and the maximal rotational diameter as an equivalent to the spherical diameter. Using a polydimethylsiloxane (PDMS)-based microfluidic device with spirals, experiments were conducted with artificial peanut-shaped and ellipsoidal particles sized between 3 and 9 μm as well as with the bacteria Bacillus subtilis. Our investigations show that the equivalent spherical diameter, the major axis, and the maximal rotational diameter of a non-spherical particle can predict successful focusing. The minor axis is not suitable for this purpose. Non-spherical particles focused when the ratio of their equivalent spherical diameter to the hydraulic diameter of the channel was larger than 0.07. The particles also focused when the ratio between the maximal rotational diameter or the major axis and the hydraulic diameter was larger than 0.01. These results may help us to separate non-spherical biological particles, such as circulating tumor cells or pathogenic bacteria, from blood in future experimental studies.

  4. Correlation between dry eye and refractive error in Saudi young adults using noninvasive Keratograph 4

    PubMed Central

    Fahmy, Rania M; Aldarwesh, Amal

    2018-01-01

    Purpose: The purpose is to study the correlation between dry eye and refractive errors in young adults using noninvasive Keratograph. Methods: In this cross sectional study, a total of 126 participants in the age range of 19–25 years and who were free of ocular surface disease, were recruited from King Saud University Campus. Refraction was defined by the spherical equivalent (SE) as the following: 49 emmetropic eyes (±0.50 SE), 48 myopic eyes (≤−0.75 SE and above), and 31 hyperopic eyes (>+0.75 SE). All participants underwent full ophthalmic examinations assessing their refractive status and dryness level including noninvasive breakup time (NIBUT) and tear meniscus height using Keratograph 4. Results: The prevalence of dry eye was 24.6%, 36.5%, and 17.4% in emmetropes, myopes, and hypermetropes, respectively. NIBUT has a negative correlation with hyperopia and a positive correlation with myopia with a significant reduction in the average NIBUT in myopes and hypermetropes in comparison to emmetropes. Conclusion: The current results succeeded to demonstrate a correlation between refractive errors and dryness level. PMID:29676308

  5. Variation in PTCHD2, CRISP3, NAP1L4, FSCB, and AP3B2 associated with spherical equivalent.

    PubMed

    Chen, Fei; Duggal, Priya; Klein, Barbara E K; Lee, Kristine E; Truitt, Barbara; Klein, Ronald; Iyengar, Sudha K; Klein, Alison P

    2016-01-01

    Ocular refraction is measured in spherical equivalent as the power of the external lens required to focus images on the retina. Myopia (nearsightedness) and hyperopia (farsightedness) are the most common refractive errors, and the leading causes of visual impairment and blindness in the world. The goal of this study is to identify rare and low-frequency variants that influence spherical equivalent. We conducted variant-level and gene-level quantitative trait association analyses for mean spherical equivalent, using data from 1,560 individuals in the Beaver Dam Eye Study. Genotyping was conducted using the Illumina exome array. We analyzed 34,976 single nucleotide variants and 11,571 autosomal genes across the genome, using single-variant tests as well as gene-based tests. Spherical equivalent was significantly associated with five genes in gene-based analysis: PTCHD2 at 1p36.22 (p = 3.6 × 10(-7)), CRISP3 at 6p12.3 (p = 4.3 × 10(-6)), NAP1L4 at 11p15.5 (p = 3.6 × 10(-6)), FSCB at 14q21.2 (p = 1.5 × 10(-7)), and AP3B2 at 15q25.2 (p = 1.6 × 10(-7)). The variant-based tests identified evidence suggestive of association with two novel variants in linkage disequilibrium (pairwise r(2) = 0.80) in the TCTE1 gene region at 6p21.1 (rs2297336, minor allele frequency (MAF) = 14.1%, β = -0.62 p = 3.7 × 10(-6); rs324146, MAF = 16.9%, β = -0.55, p = 1.4 × 10(-5)). In addition to these novel findings, we successfully replicated a previously reported association with rs634990 near GJD2 at 15q14 (MAF = 47%, β = -0.29, p=1.8 × 10(-3)). We also found evidence of association with spherical equivalent on 2q37.1 in PRSS56 at rs1550094 (MAF = 31%, β = -0.33, p = 1.7 × 10(-3)), a region previously associated with myopia. We identified several novel candidate genes that may play a role in the control of spherical equivalent. However, further studies are needed to replicate these findings. In addition, our results contribute to the increasing evidence that variation in the GJD2 and PRSS56 genes influence the development of refractive errors. Identifying that variation in these genes is associated with spherical equivalent may provide further insight into the etiology of myopia and consequent vision loss.

  6. Interocular Difference of Peripheral Refraction in Anisomyopic Eyes of Schoolchildren

    PubMed Central

    Chen, Junhong; He, Ji C.; Chen, Yunyun; Xu, Jingjing; Wu, Haoran; Wang, Feifu; Lu, Fan; Jiang, Jun

    2016-01-01

    Purpose Refraction in the peripheral visual field is believed to play an important role in the development of myopia. The purpose of this study was to investigate the differences in peripheral refraction among anisomyopia, isomyopia, and isoemmetropia for schoolchildren. Methods Thirty-eight anisomyopic children were recruited and divided into two groups: (1) both eyes were myopic (anisomyopic group, AM group) and (2) one eye was myopic and the contralateral eye was emmetropic (emmetropic anisomyopic group, EAM group). As controls, 45 isomyopic and isoemmetropic children were also recruited with age and central spherical equivalent (SE) matched to those of the AM and EAM groups. The controls were divided into three groups: (1) intermediate myopia group (SE matched to the more myopic eye of AM group), (2) low myopia group (SE matched to the less myopic eye of AM group and the more myopic eye of EAM group), and (3) emmetropia group (SE matched to the less myopic eye of EAM group). Peripheral refraction at 7 points across the central ±30° on the horizontal visual field with a 10° interval was measured with an autorefractor. Axial length (AL), corneal curvature (CC), and anterior chamber depth (ACD) were also determined by using the Zeiss IOL-Master. Results The relative peripheral spherical equivalent [RPR(M)] and relative peripheral spherical value [RPR(S)] of the more myopic eye was shifted more hyperopically than the contralateral eye in both the AM and the EAM groups (both p<0.0001). The RPR(M, S) of the less myopic eyes in the AM and EAM groups showed a relatively flat trend across the visual field and were not significantly different from the emmetropia group. The RPR(M, S) of less myopic eyes in the AM group were shifted less hyperopically than in the isomyopic low myopia group and the more myopic eye of the EAM group [RPR(M), p = 0.007; RPR(S), p = 0.001], although the central SEs of the three groups were not significantly different from each other. However, RPR(M, S) of the more myopic eyes were not different from the corresponding isomyopic groups. There was also no significant difference in the relative peripheral astigmatism [RPR(J0, J45)] between the more and the less myopic eyes in either the AM or the EAM group. Conclusion Refraction of anisomyopia differs between the two eyes not only at the central visual field but also at the off-axis periphery. The relative peripheral refraction of the more myopic eye of anisomyopia was shifted hyperopically, as occurs in isomyopia with similar central subjective SE values. Less myopic eyes were much less hyperopically shifted in relative peripheral refraction than the corresponding isomyopic eyes, but are comparable to emmetropic eyes. This emmetropia-like relative peripheral refraction in less myopic eyes might be a factor responsible for slowing down the progression of myopia. PMID:26881745

  7. Interocular Difference of Peripheral Refraction in Anisomyopic Eyes of Schoolchildren.

    PubMed

    Chen, Junhong; He, Ji C; Chen, Yunyun; Xu, Jingjing; Wu, Haoran; Wang, Feifu; Lu, Fan; Jiang, Jun

    2016-01-01

    Refraction in the peripheral visual field is believed to play an important role in the development of myopia. The purpose of this study was to investigate the differences in peripheral refraction among anisomyopia, isomyopia, and isoemmetropia for schoolchildren. Thirty-eight anisomyopic children were recruited and divided into two groups: (1) both eyes were myopic (anisomyopic group, AM group) and (2) one eye was myopic and the contralateral eye was emmetropic (emmetropic anisomyopic group, EAM group). As controls, 45 isomyopic and isoemmetropic children were also recruited with age and central spherical equivalent (SE) matched to those of the AM and EAM groups. The controls were divided into three groups: (1) intermediate myopia group (SE matched to the more myopic eye of AM group), (2) low myopia group (SE matched to the less myopic eye of AM group and the more myopic eye of EAM group), and (3) emmetropia group (SE matched to the less myopic eye of EAM group). Peripheral refraction at 7 points across the central ±30° on the horizontal visual field with a 10° interval was measured with an autorefractor. Axial length (AL), corneal curvature (CC), and anterior chamber depth (ACD) were also determined by using the Zeiss IOL-Master. The relative peripheral spherical equivalent [RPR(M)] and relative peripheral spherical value [RPR(S)] of the more myopic eye was shifted more hyperopically than the contralateral eye in both the AM and the EAM groups (both p<0.0001). The RPR(M, S) of the less myopic eyes in the AM and EAM groups showed a relatively flat trend across the visual field and were not significantly different from the emmetropia group. The RPR(M, S) of less myopic eyes in the AM group were shifted less hyperopically than in the isomyopic low myopia group and the more myopic eye of the EAM group [RPR(M), p = 0.007; RPR(S), p = 0.001], although the central SEs of the three groups were not significantly different from each other. However, RPR(M, S) of the more myopic eyes were not different from the corresponding isomyopic groups. There was also no significant difference in the relative peripheral astigmatism [RPR(J0, J45)] between the more and the less myopic eyes in either the AM or the EAM group. Refraction of anisomyopia differs between the two eyes not only at the central visual field but also at the off-axis periphery. The relative peripheral refraction of the more myopic eye of anisomyopia was shifted hyperopically, as occurs in isomyopia with similar central subjective SE values. Less myopic eyes were much less hyperopically shifted in relative peripheral refraction than the corresponding isomyopic eyes, but are comparable to emmetropic eyes. This emmetropia-like relative peripheral refraction in less myopic eyes might be a factor responsible for slowing down the progression of myopia.

  8. Spherical earth gravity and magnetic anomaly analysis by equivalent point source inversion

    NASA Technical Reports Server (NTRS)

    Von Frese, R. R. B.; Hinze, W. J.; Braile, L. W.

    1981-01-01

    To facilitate geologic interpretation of satellite elevation potential field data, analysis techniques are developed and verified in the spherical domain that are commensurate with conventional flat earth methods of potential field interpretation. A powerful approach to the spherical earth problem relates potential field anomalies to a distribution of equivalent point sources by least squares matrix inversion. Linear transformations of the equivalent source field lead to corresponding geoidal anomalies, pseudo-anomalies, vector anomaly components, spatial derivatives, continuations, and differential magnetic pole reductions. A number of examples using 1 deg-averaged surface free-air gravity anomalies of POGO satellite magnetometer data for the United States, Mexico, and Central America illustrate the capabilities of the method.

  9. Refractive errors in medical students in Singapore.

    PubMed

    Woo, W W; Lim, K A; Yang, H; Lim, X Y; Liew, F; Lee, Y S; Saw, S M

    2004-10-01

    Refractive errors are becoming more of a problem in many societies, with prevalence rates of myopia in many Asian urban countries reaching epidemic proportions. This study aims to determine the prevalence rates of various refractive errors in Singapore medical students. 157 second year medical students (aged 19-23 years) in Singapore were examined. Refractive error measurements were determined using a stand-alone autorefractor. Additional demographical data was obtained via questionnaires filled in by the students. The prevalence rate of myopia in Singapore medical students was 89.8 percent (Spherical equivalence (SE) at least -0.50 D). Hyperopia was present in 1.3 percent (SE more than +0.50 D) of the participants and the overall astigmatism prevalence rate was 82.2 percent (Cylinder at least 0.50 D). Prevalence rates of myopia and astigmatism in second year Singapore medical students are one of the highest in the world.

  10. Variation in PTCHD2, CRISP3, NAP1L4, FSCB, and AP3B2 associated with spherical equivalent

    PubMed Central

    Chen, Fei; Duggal, Priya; Klein, Barbara E.K.; Lee, Kristine E.; Truitt, Barbara; Klein, Ronald; Iyengar, Sudha K.

    2016-01-01

    Purpose Ocular refraction is measured in spherical equivalent as the power of the external lens required to focus images on the retina. Myopia (nearsightedness) and hyperopia (farsightedness) are the most common refractive errors, and the leading causes of visual impairment and blindness in the world. The goal of this study is to identify rare and low-frequency variants that influence spherical equivalent. Methods We conducted variant-level and gene-level quantitative trait association analyses for mean spherical equivalent, using data from 1,560 individuals in the Beaver Dam Eye Study. Genotyping was conducted using the Illumina exome array. We analyzed 34,976 single nucleotide variants and 11,571 autosomal genes across the genome, using single-variant tests as well as gene-based tests. Results Spherical equivalent was significantly associated with five genes in gene-based analysis: PTCHD2 at 1p36.22 (p = 3.6 × 10−7), CRISP3 at 6p12.3 (p = 4.3 × 10−6), NAP1L4 at 11p15.5 (p = 3.6 × 10−6), FSCB at 14q21.2 (p = 1.5 × 10−7), and AP3B2 at 15q25.2 (p = 1.6 × 10−7). The variant-based tests identified evidence suggestive of association with two novel variants in linkage disequilibrium (pairwise r2 = 0.80) in the TCTE1 gene region at 6p21.1 (rs2297336, minor allele frequency (MAF) = 14.1%, β = –0.62 p = 3.7 × 10−6; rs324146, MAF = 16.9%, β = –0.55, p = 1.4 × 10−5). In addition to these novel findings, we successfully replicated a previously reported association with rs634990 near GJD2 at 15q14 (MAF = 47%, β = –0.29, p=1.8 × 10−3). We also found evidence of association with spherical equivalent on 2q37.1 in PRSS56 at rs1550094 (MAF = 31%, β = –0.33, p = 1.7 × 10−3), a region previously associated with myopia. Conclusions We identified several novel candidate genes that may play a role in the control of spherical equivalent. However, further studies are needed to replicate these findings. In addition, our results contribute to the increasing evidence that variation in the GJD2 and PRSS56 genes influence the development of refractive errors. Identifying that variation in these genes is associated with spherical equivalent may provide further insight into the etiology of myopia and consequent vision loss. PMID:27440996

  11. Optical equivalence of isotropic ensembles of ellipsoidal particles in the Rayleigh-Gans-Debye and anomalous diffraction approximations and its consequences

    NASA Astrophysics Data System (ADS)

    Paramonov, L. E.

    2012-05-01

    Light scattering by isotropic ensembles of ellipsoidal particles is considered in the Rayleigh-Gans-Debye approximation. It is proved that randomly oriented ellipsoidal particles are optically equivalent to polydisperse randomly oriented spheroidal particles and polydisperse spherical particles. Density functions of the shape and size distributions for equivalent ensembles of spheroidal and spherical particles are presented. In the anomalous diffraction approximation, equivalent ensembles of particles are shown to also have equal extinction, scattering, and absorption coefficients. Consequences of optical equivalence are considered. The results are illustrated by numerical calculations of the angular dependence of the scattering phase function using the T-matrix method and the Mie theory.

  12. The Correlation between Angle Kappa and Ocular Biometry in Koreans

    PubMed Central

    Choi, Se Rang

    2013-01-01

    Purpose To investigate normative angle kappa data and to examine whether correlations exist between angle kappa and ocular biometric measurements (e.g., refractive error, axial length) and demographic features in Koreans. Methods Data from 436 eyes (213 males and 223 females) were analyzed in this study. The angle kappa was measured using Orbscan II. We used ocular biometric measurements, including refractive spherical equivalent, interpupillary distance and axial length, to investigate the correlations between angle kappa and ocular biometry. The IOL Master ver. 5.02 was used to obtain axial length. Results The mean patient age was 57.5 ± 12.0 years in males and 59.4 ± 12.4 years in females (p = 0.11). Angle kappa averaged 4.70 ± 2.70 degrees in men and 4.89 ± 2.14 degrees in women (p = 0.48). Axial length and spherical equivalent were correlated with angle kappa (r = -0.342 and r = 0.197, respectively). The correlation between axial length and spherical equivalent had a negative correlation (r = -0.540, p < 0.001). Conclusions Angle kappa increased with spherical equivalent and age. Thus, careful manipulation should be considered in older and hyperopic patients when planning refractive or strabismus surgery. PMID:24311927

  13. Refraction and Ocular Biometry of Preschool Children in Shanghai, China

    PubMed Central

    He, Xiangui; You, Xiaofang; Wang, Bingjie; Tan, Hui; Zhu, Jianfeng

    2018-01-01

    Purpose To investigate the refraction and ocular biometry characteristics and to examine the prevalence of refractive errors in preschool children aged 3 to 6 years in Shanghai, China. Methods A school-based cross-sectional study was conducted in Jiading and Xuhui District, Shanghai, in 2013. We randomly selected 7 kindergartens in Jiading District and 10 kindergartens in Xuhui District, with a probability proportionate to size. The children underwent comprehensive eye examinations, including cycloplegic refraction and biometric measurements. Myopia, hyperopia, astigmatism were defined as spherical equivalent (SE) ≤ −0.50 D, SE ≥ +2.00 D, and cylindrical diopters ≤ −1.00 D. Results The mean SE for 3- to 6-year-old children was +1.20 D (standard deviation [SD] 1.05), and the mean axial length (AL) was 22.29 mm (SD 0.73). The overall prevalence of myopia and astigmatism was 3.7% and 18.3%, respectively. No difference in prevalence of astigmatism was found across age groups. There was a statistically significant association between lower cylindrical diopters and higher spherical diopters (Spearman's correlation: −0.21, P < 0.001). Conclusion Chinese children aged 3 to 6 years in the Shanghai area were mostly mildly hyperopic, with a low prevalence of myopia. Refractive astigmatism for children may be relatively stable throughout the preschool stage. Astigmatism was significantly associated with refractive error. PMID:29692930

  14. High energy neutron dosimeter

    DOEpatents

    Sun, Rai Ko S.F.

    1994-01-01

    A device for measuring dose equivalents in neutron radiation fields. The device includes nested symmetrical hemispheres (forming spheres) of different neutron moderating materials that allow the measurement of dose equivalents from 0.025 eV to past 1 GeV. The layers of moderating material surround a spherical neutron counter. The neutron counter is connected by an electrical cable to an electrical sensing means which interprets the signal from the neutron counter in the center of the moderating spheres. The spherical shape of the device allows for accurate measurement of dose equivalents regardless of its positioning.

  15. High energy neutron dosimeter

    DOEpatents

    Rai, K.S.F.

    1994-01-11

    A device for measuring dose equivalents in neutron radiation fields is described. The device includes nested symmetrical hemispheres (forming spheres) of different neutron moderating materials that allow the measurement of dose equivalents from 0.025 eV to past 1 GeV. The layers of moderating material surround a spherical neutron counter. The neutron counter is connected by an electrical cable to an electrical sensing means which interprets the signal from the neutron counter in the center of the moderating spheres. The spherical shape of the device allows for accurate measurement of dose equivalents regardless of its positioning. 2 figures.

  16. Ametropia, retinal anatomy, and OCT abnormality patterns in glaucoma. 1. Impacts of refractive error and interartery angle

    NASA Astrophysics Data System (ADS)

    Elze, Tobias; Baniasadi, Neda; Jin, Qingying; Wang, Hui; Wang, Mengyu

    2017-12-01

    Retinal nerve fiber layer thickness (RNFLT) measured by optical coherence tomography (OCT) is widely used in clinical practice to support glaucoma diagnosis. Clinicians frequently interpret peripapillary RNFLT areas marked as abnormal by OCT machines. However, presently, clinical OCT machines do not take individual retinal anatomy variation into account, and according diagnostic biases have been shown particularly for patients with ametropia. The angle between the two major temporal retinal arteries (interartery angle, IAA) is considered a fundamental retinal ametropia marker. Here, we analyze peripapillary spectral domain OCT RNFLT scans of 691 glaucoma patients and apply multivariate logistic regression to quantitatively compare the diagnostic bias of spherical equivalent (SE) of refractive error and IAA and to identify the precise retinal locations of false-positive/negative abnormality marks. Independent of glaucoma severity (visual field mean deviation), IAA/SE variations biased abnormality marks on OCT RNFLT printouts at 36.7%/22.9% of the peripapillary area, respectively. 17.2% of the biases due to SE are not explained by IAA variation, particularly in inferonasal areas. To conclude, the inclusion of SE and IAA in OCT RNFLT norms would help to increase diagnostic accuracy. Our detailed location maps may help clinicians to reduce diagnostic bias while interpreting retinal OCT scans.

  17. Refractive Errors and Concomitant Strabismus: A Systematic Review and Meta-analysis.

    PubMed

    Tang, Shu Min; Chan, Rachel Y T; Bin Lin, Shi; Rong, Shi Song; Lau, Henry H W; Lau, Winnie W Y; Yip, Wilson W K; Chen, Li Jia; Ko, Simon T C; Yam, Jason C S

    2016-10-12

    This systematic review and meta-analysis is to evaluate the risk of development of concomitant strabismus due to refractive errors. Eligible studies published from 1946 to April 1, 2016 were identified from MEDLINE and EMBASE that evaluated any kinds of refractive errors (myopia, hyperopia, astigmatism and anisometropia) as an independent factor for concomitant exotropia and concomitant esotropia. Totally 5065 published records were retrieved for screening, 157 of them eligible for detailed evaluation. Finally 7 population-based studies involving 23,541 study subjects met our criteria for meta-analysis. The combined OR showed that myopia was a risk factor for exotropia (OR: 5.23, P = 0.0001). We found hyperopia had a dose-related effect for esotropia (OR for a spherical equivalent [SE] of 2-3 diopters [D]: 10.16, P = 0.01; OR for an SE of 3-4D: 17.83, P < 0.0001; OR for an SE of 4-5D: 41.01, P < 0.0001; OR for an SE of ≥5D: 162.68, P < 0.0001). Sensitivity analysis indicated our results were robust. Results of this study confirmed myopia as a risk for concomitant exotropia and identified a dose-related effect for hyperopia as a risk of concomitant esotropia.

  18. Refractive Errors and Concomitant Strabismus: A Systematic Review and Meta-analysis

    PubMed Central

    Tang, Shu Min; Chan, Rachel Y. T.; Bin Lin, Shi; Rong, Shi Song; Lau, Henry H. W.; Lau, Winnie W. Y.; Yip, Wilson W. K.; Chen, Li Jia; Ko, Simon T. C.; Yam, Jason C. S.

    2016-01-01

    This systematic review and meta-analysis is to evaluate the risk of development of concomitant strabismus due to refractive errors. Eligible studies published from 1946 to April 1, 2016 were identified from MEDLINE and EMBASE that evaluated any kinds of refractive errors (myopia, hyperopia, astigmatism and anisometropia) as an independent factor for concomitant exotropia and concomitant esotropia. Totally 5065 published records were retrieved for screening, 157 of them eligible for detailed evaluation. Finally 7 population-based studies involving 23,541 study subjects met our criteria for meta-analysis. The combined OR showed that myopia was a risk factor for exotropia (OR: 5.23, P = 0.0001). We found hyperopia had a dose-related effect for esotropia (OR for a spherical equivalent [SE] of 2–3 diopters [D]: 10.16, P = 0.01; OR for an SE of 3-4D: 17.83, P < 0.0001; OR for an SE of 4-5D: 41.01, P < 0.0001; OR for an SE of ≥5D: 162.68, P < 0.0001). Sensitivity analysis indicated our results were robust. Results of this study confirmed myopia as a risk for concomitant exotropia and identified a dose-related effect for hyperopia as a risk of concomitant esotropia. PMID:27731389

  19. Comparison between toric and spherical phakic intraocular lenses combined with astigmatic keratotomy for high myopic astigmatism.

    PubMed

    Zheng, Lin-Yan; Zhu, Shuang-Qian; Su, Yan-Feng; Zou, Hu-Yong; Wang, Qin-Mei; Yu, A-Yong

    2017-01-01

    To compare the outcomes of a toric phakic intraocular lens (PIOL) and a spherical PIOL combined with astigmatic keratotomy (AK) for the correction of high myopic astigmatism. This study enrolled patients with high myopic astigmatism, including 30 eyes (22 patients) that received a toric PIOL implantation (TICL group), and 32 eyes (24 patients) that received combined AK and a spherical PIOL implantation (AK+ ICL group). The outcomes were compared between the two groups before surgery, and at the following time points after surgery: 1 week, 1, 3, 6 months, and 1, 2 years. Preoperatively, the mean manifest spherical equivalent (SE) was -14.14 ± 2.12 D in the TICL group and -14.83 ± 2.79 D in the AK + ICL group ( P  = 0.28), and the mean manifest refractive cylinder, -2.87 ± 1.09 D and -2.58 ± 0.85 D, respectively ( P  = 0.28). Two years postoperatively, the mean safety index was 1.53 ± 0.55 in the TICL group and 1.60 ± 0.70 in the AK + ICL group ( P  = 1.00), and the mean efficacy index, 1.18 ± 0.45 and 1.38 ± 0.52, respectively ( P  = 0.86). The mean manifest refractive cylinder correction was 1.94 ± 1.07 D in the TICL group and 1.39 ± 0.71 D in the AK + ICL group ( P  = 0.02). The mean changes in SE and refractive cylinder from 1 week to 2 years were less than 0.50 D in both groups. Both TICL implantation and AK + ICL implantation are a good alternative for correction of astigmatism in addition to high myopia. TICL implantation has better predictability in correction of high myopic astigmatism. NCT03202485.

  20. Prevalence of Refractive Error among Preschool Children in an Urban Population: The Baltimore Pediatric Eye Disease Study

    PubMed Central

    Giordano, Lydia; Friedman, David S.; Repka, Michael X.; Katz, Joanne; Ibironke, Josephine; Hawes, Patricia; Tielsch, James M.

    2009-01-01

    Purpose To determine the age-specific prevalence of refractive errors in White and African-American preschool children. Design The Baltimore Pediatric Eye Disease Study is a population-based evaluation of the prevalence of ocular disorders in children aged six through 71 months in Baltimore, Maryland, United States. Participants Among 4,132 children identified, 3,990 eligible children (97%) were enrolled and 2,546 children (62%) were examined. Methods Cycloplegic autorefraction was attempted on all children using a Nikon Retinomax K-Plus 2. If a reliable autorefraction could not be obtained after three attempts, cycloplegic streak retinoscopy was performed. Main Outcome Measures Mean spherical equivalent (SE) refractive error, astigmatism, and prevalence of higher refractive errors among African American and White children. Results The mean spherical equivalent (SE) of right eyes was +1.49 diopter (D) (standard deviation (SD) =1.23) in White and +0.71D (SD=1.35) in African-American children (mean difference of 0.78D, 95% CI: 0.67, 0.89). Mean SE refractive error did not decline with age in either group. The prevalence of myopia of 1.00 D or more in the eye with the lesser refractive error was 0.7% in White and 5.5% in African-American children (RR: 8.01 95% confidence interval (CI): 3.70, 17.35). The prevalence of hyperopia of +3D or more in the eye with the lesser refractive error was 8.9% in White and 4.4% in African-American children (relative risk (RR): 0.49, 95% CI: 0.35, 0.68). The prevalence of emmetropia (less than −1.00 D to less than +1.00 D) was 35.6% in Whites and 58.0 % in African-Americans (RR: 1.64, 95% CI: 1.49, 1.80). Based on published prescribing guidelines 5.1% of the children would have benefited from spectacle correction. However, only 1.3% had been previously prescribed correction. Conclusions Significant refractive errors are uncommon in this population of urban preschool children. There was no evidence for a myopic shift over this age range in this cross-sectional study. A small proportion of preschool children would likely benefit from refractive correction, but few have had this prescribed. PMID:19243832

  1. Outcomes of small incision lenticule extraction (SMILE) in low myopia.

    PubMed

    Reinstein, Dan Z; Carp, Glenn I; Archer, Timothy J; Gobbe, Marine

    2014-12-01

    To report the visual and refractive outcomes of small incision lenticule extraction for low myopia using the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany). A retrospective analysis of 120 consecutive small incision lenticule extraction procedures was performed for low myopia. Inclusion criteria were preoperative spherical equivalent refraction up to -3.50 diopters (D), cylinder up to 1.50 D, and corrected distance visual acuity of 20/20 or better. Outcomes analysis was performed for all eyes with 1-year follow-up according to the Standard Graphs for Reporting Refractive Surgery, and also including mesopic contrast sensitivity. One-year data were available for 110 eyes (92%). Preoperatively, mean spherical equivalent refraction was -2.61 ± 0.54 D (range: -1.03 to -3.50 D) and mean cylinder was 0.55 ± 0.38 D (range: 0.00 to 1.50 D). Postoperatively, mean spherical equivalent refraction was -0.05 ± 0.36 D (range: -0.94 to +1.25 D) and mean cylinder was ± 0.50 D in 84% and ± 1.00 D in 99% of eyes. Uncorrected distance visual acuity was 20/20 or better in 96% of eyes and 20/25 or better in 100% of eyes. One line of corrected distance visual acuity was lost in 9%, but no eyes lost two or more lines. There was an initial overcorrection in mean spherical equivalent refraction on day 1 (+0.37 D) as expected, which regressed to +0.10 D at 1 month and -0.05 D at 3 months, after which stability was reached (mean spherical equivalent refraction was -0.05 D at 1 year). Contrast sensitivity at 1 year was slightly increased at 3, 6, 12, and 18 cycles per degree (P < .05). Small incision lenticule extraction for low myopia was found to be safe and effective with outcomes similar to those previously reported for LASIK. Copyright 2014, SLACK Incorporated.

  2. Effect of Nd:YAG laser capsulotomy on refraction in multifocal apodized diffractive pseudophakia.

    PubMed

    Vrijman, Violette; van der Linden, Jan Willem; Nieuwendaal, Carla P; van der Meulen, Ivanka J E; Mourits, Maarten P; Lapid-Gortzak, Ruth

    2012-08-01

    To evaluate the effect on refraction of neodymium:YAG (Nd:YAG) laser posterior capsulotomy for posterior capsule opacification (PCO), and to evaluate the correlation between automated and subjective refraction in multifocal apodized diffractive pseudophakia. A retrospective study of 75 pseudophakic eyes (50 patients) with multifocal apodized diffractive pseudophakia, treated for PCO with Nd:YAG laser posterior capsulotomy, was performed. Pre- and postintervention values of refractive and visual parameters were compared. The outcomes of autorefraction and subjective refraction were also compared. Uncorrected and corrected distance visual acuity improved significantly after Nd:YAG capsulotomy (P<.001). No significant changes were noted in defocus equivalent, astigmatic power vectors J(0) and J(45), and overall blurring strength in subjective refraction and autorefraction. Spherical equivalent changed significantly in autorefraction (P=.008), but not in subjective refraction. Autorefraction and subjective refraction were highly correlated in spherical equivalent, defocus equivalent, and blurring strength (r(2)>0.59). In approximately 7% of eyes, a change of more than 0.50 diopters in spherical equivalent in subjective refraction occurred. In most cases, Nd:YAG laser capsulotomy in patients with multifocal pseudophakia did not result in a change in refraction. However, 7% of eyes experienced a significant change in subjective refraction. Autorefraction correlated well with subjective refraction in apodized diffractive multifocal IOLs. Copyright 2012, SLACK Incorporated.

  3. Comparison of visual results and higher-order aberrations after small incision lenticule extraction (SMILE): high myopia vs. mild to moderate myopia.

    PubMed

    Jin, Hong-Ying; Wan, Ting; Wu, Fang; Yao, Ke

    2017-07-06

    To compare the refractive results and higher-order aberrations (HOAs) after small incision lenticule extraction (SMILE) in high myopia and mild to moderate myopia patients. This prospective study included 165 eyes (86 patients) undergoing SMILE. According to the preoperative spherical equivalent (SE), treated eyes were divided into two groups: the high myopia group (more than -6.0 D, group-H) and the mild to moderate group (less than -6.0 D, group-M). Follow-up intervals were at 1 day, 10 days, 1 month and 3 months postoperatively. We obtained the following parameters: uncorrected (UDVA) and corrected distance visual acuity (CDVA), SE, efficacy and safety index, and HOAs. Preoperative SE was -7.16 ± 0.93 D in group-H and -4.34 ± 0.97 D in group-M. At 3 months postoperatively, the SE in group-H and group-M was -0.20 ± 0.37 D and 0.01 ± 0.19 D (t = - 4.11, P<0.05), respectively. It was found that 77% and 98% had an UDVA of 20/20, 98% and 99% had a CDVA of 20/20 in group-H and group-M, respectively, while 87% and 95% had a SE within ±0.5 D and ±1.0 D in group-H, and 98% and 100% in group-M. The efficacy indexes were 0.98 ± 0.18 in group-H and 1.05 ± 0.10 in group-M (t = - 3.084, p < 0.05). The safety indexes were 1.06 ± 0.09 and 1.06 ± 0.09 (t = 0.153, p > 0.05), respectively. There were significant increases in total HOAs, 3 rd -order coma, and 4 th -order spherical aberrations. SMILE is an effective and safe surgery for correcting myopia. But the target correction amount in high myopia patients should be adjusted to avoid undercorrection and acquired more satisfaction. SMILE induced increases of HOAs. ChiTrial registration number: ChiCTR-OON-16009164 . Retrospectively registered: 06.September.2016.

  4. Myopic refractive shift represents dense nuclear sclerosis and thin lens in lenticular myopia.

    PubMed

    Cho, Yang Kyung; Huang, Wei; Nishimura, Eiichi

    2013-09-01

    It is not rare to meet unilateral nuclear sclerotic cataracts with myopic refractive changes (lenticular myopia) compared with the fellow eye in the ophthalmic examination of patients with decreased visual acuity. To determine the relationship between the myopic refractive changes and interocular differences of parameters, we investigated the interocular differences of ocular parameters between a lenticular myopic eye and the fellow eye. This retrospective study included 68 eyes of 34 patients, who showed unilateral lenticular myopia. We compared the dimensions of ocular component, such as anterior chamber depth, anterior chamber volume, lens thickness, vitreous chamber depth, lens position, lens density of nuclear sclerosis, anterior lens curvature and myopic refractive changes (spherical equivalent refraction) between the lenticular myopic eye and the myopic refractive change were examined. Statistically significant differences were found between the lenticular myopic eye and the fellow eye for anterior chamber depth (p = 0.015) anterior chamber volume (p = 0.031), lens thickness (p < 0.001), lens density of the nuclear sclerosis (p < 0.001) and the spherical equivalent myopic refractive changes (p < 0.001). Based on univariate analysis, the interocular difference in spherical equivalent refraction was significantly correlated with interocular differences of the density of the nuclear sclerosis (r = 0.79, p < 0.001), lens thickness (r = -0.70, p < 0.001) and vitreous chamber depth (r = 0.43, p = 0.012). Based on multiple regression analysis, the interocular difference in spherical equivalent refraction was significantly correlated with interocular differences of density of nuclear sclerosis (p < 0.001) and lens thickness (p = 0.007). The difference in myopic spherical change reflects the differences in the severity of nuclear sclerosis and lens thickness between the lenticular myopic eye and the fellow eye. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

  5. Six-month clinical outcomes after hyperopic correction with the SCHWIND AMARIS Total-Tech laser

    PubMed Central

    Arbelaez, María Clara; Vidal, Camila; Arba Mosquera, Samuel

    2011-01-01

    Purpose To evaluate postoperative clinical outcomes, and corneal High Order Aberrations, among eyes with hyperopia up to +5 D of spherical equivalent, that have undergone LASIK treatments using the SCHWIND AMARIS laser system. Methods At six-month follow-up, 100 eyes with preoperative hyperopia or hyperopic astigmatism up to +5 D of spherical equivalent were retrospectively analysed. Standard examinations, pre- and postoperative wavefront analysis with a corneal-wavefront-analyzer (OPTIKON Scout) were performed. Aberration-Free aspheric treatments were planned with Custom Ablation Manager software and ablations performed using the SCHWIND AMARIS flying-spot excimer laser system (both SCHWIND eye-tech-solutions). LASIK flaps were created using a LDV femtosecond laser (Ziemer Group) in all cases. Clinical outcomes were evaluated in terms of predictability, refractive outcome, safety, and wavefront aberration. Results At six month, 90 % of eyes achieved ≥ 20/25 UCVA and 44 % achieved ≥ 20/16 UCVA. Seventy-four percent of eyes were within ± 0.25D of spherical equivalent and 89 % within ± 0.50D, with 94 % within 0.50D of astigmatism. Mean spherical equivalent was −0.12 ± 0.51D and 0.50 ± 0.51D for the astigmatism. Fifty-two percent of eyes improved BSCVA vs. only 19 % losing lines of BSCVA. Predictability slope for refraction was 1.03 and intercept +0.01 D. On average, negative corneal spherical aberrations were significantly increased by the treatments, no other aberration terms changed from pre- to postoperative values. Conclusions LASIK for hyperopia and hyperopic astigmatism with SCHWIND AMARIS yields very satisfactory visual outcomes. Preoperative refractions were postoperatively reduced to subclinical values with no clinically relevant induction of corneal HOA.

  6. Influence of shape and gradient refractive index in the accommodative changes of spherical aberration in nonhuman primate crystalline lenses.

    PubMed

    de Castro, Alberto; Birkenfeld, Judith; Maceo, Bianca; Manns, Fabrice; Arrieta, Esdras; Parel, Jean-Marie; Marcos, Susana

    2013-09-11

    To estimate changes in surface shape and gradient refractive index (GRIN) profile in primate lenses as a function of accommodation. To quantify the contribution of surface shape and GRIN to spherical aberration changes with accommodation. Crystalline lenses from 15 cynomolgus monkeys were studied in vitro under different levels of accommodation produced by a stretching system. Lens shape was obtained from optical coherence tomography (OCT) cross-sectional images. The GRIN was reconstructed with a search algorithm using the optical path measured from OCT images and the measured back focal length. The spherical aberration of the lens was estimated as a function of accommodation using the reconstructed GRIN and a homogeneous refractive index. The lens anterior and posterior radii of curvature decreased with increasing lens power. Both surfaces exhibited negative asphericities in the unaccommodated state. The anterior surface conic constant shifted toward less negative values with accommodation, while the value of the posterior remained constant. GRIN parameters remained constant with accommodation. The lens spherical aberration with GRIN distribution was negative and higher in magnitude than that with a homogeneous equivalent refractive index (by 29% and 53% in the unaccommodated and fully accommodated states, respectively). Spherical aberration with the equivalent refractive index shifted with accommodation toward negative values (-0.070 μm/diopter [D]), but the reconstructed GRIN shifted it farther (-0.124 μm/D). When compared with the lens with the homogeneous equivalent refractive index, the reconstructed GRIN lens has more negative spherical aberration and a larger shift toward more negative values with accommodation.

  7. Equivalent source modeling of the core magnetic field using magsat data

    NASA Technical Reports Server (NTRS)

    Mayhew, M. A.; Estes, R. H.

    1983-01-01

    Experiments are carried out on fitting the main field using different numbers of equivalent sources arranged in equal area at fixed radii at and inside the core-mantle boundary. In fixing the radius for a given series of runs, the convergence problems that result from the extreme nonlinearity of the problem when dipole positions are allowed to vary are avoided. Results are presented from a comparison between this approach and the standard spherical harmonic approach for modeling the main field in terms of accuracy and computational efficiency. The modeling of the main field with an equivalent dipole representation is found to be comparable to the standard spherical harmonic approach in accuracy. The 32 deg dipole density (42 dipoles) corresponds approximately to an eleventh degree/order spherical harmonic expansion (143 parameters), whereas the 21 dipole density (92 dipoles) corresponds to approximately a seventeenth degree and order expansion (323 parameters). It is pointed out that fixing the dipole positions results in rapid convergence of the dipole solutions for single-epoch models.

  8. Combined astigmatic keratotomy and conductive keratoplasty to correct high corneal astigmatism.

    PubMed

    Sy, Mary Ellen; Kovoor, Timmy A; Tannan, Anjali; Choi, Daniel; Deng, Sophie X; Danesh, Jennifer; Hamilton, D Rex

    2015-05-01

    To determine the safety, efficacy, and predictability of combined astigmatic keratotomy (AK) and conductive keratoplasty (CK) for treating high corneal astigmatism. University of California-Los Angeles, Los Angeles, California, USA. Retrospective case series. From January 1, 2004, to December 31, 2009, AK and CK were performed in eyes with corneal astigmatism of 5.0 diopters (D) or more after keratoplasty or trauma. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, spherical equivalent (SE), defocus equivalent, mean astigmatism, efficacy index, and complications were evaluated. In 11 eyes of 11 patients, the mean UDVA improved from 1.54 logMAR ± 0.50 (SD) preoperatively to 0.69 ± 0.62 logMAR 3 months postoperatively (P < .001) and the mean CDVA from 0.55 ± 0.62 logMAR to 0.12 ± 0.11 logMAR (P = .028). The mean SE and mean defocus equivalent decreased from -1.25 ± 5.06 D to 3.13 ± 3.06 D (P = .15) and from 7.98 ± 4.41 D to 6.97 ± 3.73 D (P = .45), respectively; these changes were not statistically significant. The mean absolute astigmatism decreased from 10.25 ± 4.71 D to 4.31 ± 2.34 D (P < .001). The mean absolute orthogonal and mean oblique astigmatism showed a statistically significant decrease. The efficacy index was 0.82. One case of wound gape after AK required suturing. No infectious keratitis, corneal perforation, or graft rejection occurred. Results indicate that combined AK and CK is safe and effective for correcting high corneal astigmatism after surgery or trauma. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Comparison of cycloplegic refraction between Grand Seiko autorefractor and Retinomax autorefractor in the Vision in Preschoolers–Hyperopia in Preschoolers (VIP-HIP) Study

    PubMed Central

    Ying, Gui-shuang; Maguire, Maureen G.; Kulp, Marjean Taylor; Ciner, Elise; Moore, Bruce; Pistilli, Maxwell; Candy, Rowan

    2017-01-01

    PURPOSE To evaluate the agreement of cycloplegic refractive error measures between the Grand Seiko and Retinomax autorefractors in 4- and 5-year-old children. METHODS Cycloplegic refractive error of children was measured using the Grand Seiko and Retinomax during a comprehensive eye examination. Accommodative error was measured using the Grand Seiko. The differences in sphere, cylinder, spherical equivalent (SE) and intereye vector dioptric distance (VDD) between autorefractors were assessed using the Bland-Altman plot and 95% limits of agreement (95% LoA). RESULTS A total of 702 examinations were included. Compared to the Retinomax, the Grand Seiko provided statistically significantly larger values of sphere (mean difference, 0.34 D; 95% LoA, −0.46 to 1.14 D), SE (mean, 0.25 D; 95% LoA, −0.55 to 1.05 D), VDD (mean, 0.19 D; 95% LoA, −0.67 to 1.05 D), and more cylinder (mean, −0.18 D; 95% LoA, −0.91 to 0.55 D). The Grand Seiko measured ≥0.5 D than Retinomax in 43.1% of eyes for sphere and 29.8% of eyes for SE. In multivariate analysis, eyes with SE of >4 D (based on the average of two autorefractors) had larger differences in sphere (mean, 0.66 D vs 0.35 D; P < 0.0001) and SE (0.57 D vs 0.26 D; P < 0.0001) than eyes with SE of ≤4 D. CONCLUSIONS Under cycloplegia, the Grand Seiko provided higher measures of sphere, more cylinder, and higher SE than the Retinomax. Higher refractive error was associated with larger differences in sphere and SE between the Grand Seiko and Retinomax. (J AAPOS 2017;21: 219–223) PMID:28528993

  10. Evaluation of Refractive Errors and Ocular Biometric Outcomes after Intravitreal Bevacizumab for Retinopathy of Prematurity.

    PubMed

    Gunay, Murat; Sekeroglu, Mehmet Ali; Bardak, Handan; Celik, Gokhan; Esenulku, Cenap Mahmut; Hekimoglu, Emre; Bardak, Yavuz

    2016-06-01

    To assess ocular biometric outcomes following intravitreal bevacizumab (IVB) monotherapy for retinopathy of prematurity (ROP) and compare these results with those of laser photocoagulated infants and with the ones with spontaneously regressed ROP. Premature infants including those who underwent IVB monotherapy (Group 1) or laser photocoagulation (Group 2) for ROP and infants with spontaneously regressed ROP (Group 3) were recruited for the study. Refractive errors and ocular biometric parameters (Axial length [AL], anterior chamber depth [ACD], and lens thickness [LT]) were measured at adjusted 1 year of age in all subjects. There was no significant difference of spherical equivalent (SE) value between the groups (P = 0.781). The incidence of high myopia was 7.4% in Group 1 and 12.7% in Group 2 (P = 0.081). No infants exhibited high myopia in Group 3. LT was greater in Group 2 when compared to Group 1 and Group 3 (P = 0.011). Lower SE was significantly correlated to longer AL in Group 1 (r = -0.656, P = 0.015). There was a significant positive correlation between SE and ACD values in Group 2 (r = 0.391, P = 0.005). The study showed no significant difference of SE between the groups. High myopia was only present among the treated infants either with IVB or laser. Infants who received laser treatment significantly had thicker lenses.

  11. [Intraoperative Measurement of Refraction with a Hand-Held Autorefractometer].

    PubMed

    Gesser, C; Küper, T; Richard, G; Hassenstein, A

    2015-07-01

    The aim of this study was to evaluate an intraoperative measurement of objective refraction with a hand-held retinomax instrument. At the end of cataract surgery objective refraction in a lying position was measured with a retinomax instrument. On the first postoperative day the same measurement was performed with a retinomax and a standard autorefractometer. To evaluate the differences between measurements, the spherical equivalent (SE) and Jackson's cross cylinder at 0° (J0) and 45° (J45) was used. 103 eyes were included. 95 of them had normal cataract surgery. Differences between retinomax at the operative day and the standard autorefractometer were 0.68 ± 2.58 D in SE, 0.05 ± 1.4D in J0 and 0.05 ± 1.4D in J45. There were no statistically significant differences between the groups. Intraoperative measurement of the refraction with a retinomax can predict the postoperative refraction. Nevertheless, in a few patients great differences may occur. Georg Thieme Verlag KG Stuttgart · New York.

  12. Influence of Shape and Gradient Refractive Index in the Accommodative Changes of Spherical Aberration in Nonhuman Primate Crystalline Lenses

    PubMed Central

    de Castro, Alberto; Birkenfeld, Judith; Maceo, Bianca; Manns, Fabrice; Arrieta, Esdras; Parel, Jean-Marie; Marcos, Susana

    2013-01-01

    Purpose. To estimate changes in surface shape and gradient refractive index (GRIN) profile in primate lenses as a function of accommodation. To quantify the contribution of surface shape and GRIN to spherical aberration changes with accommodation. Methods. Crystalline lenses from 15 cynomolgus monkeys were studied in vitro under different levels of accommodation produced by a stretching system. Lens shape was obtained from optical coherence tomography (OCT) cross-sectional images. The GRIN was reconstructed with a search algorithm using the optical path measured from OCT images and the measured back focal length. The spherical aberration of the lens was estimated as a function of accommodation using the reconstructed GRIN and a homogeneous refractive index. Results. The lens anterior and posterior radii of curvature decreased with increasing lens power. Both surfaces exhibited negative asphericities in the unaccommodated state. The anterior surface conic constant shifted toward less negative values with accommodation, while the value of the posterior remained constant. GRIN parameters remained constant with accommodation. The lens spherical aberration with GRIN distribution was negative and higher in magnitude than that with a homogeneous equivalent refractive index (by 29% and 53% in the unaccommodated and fully accommodated states, respectively). Spherical aberration with the equivalent refractive index shifted with accommodation toward negative values (−0.070 μm/diopter [D]), but the reconstructed GRIN shifted it farther (−0.124 μm/D). Conclusions. When compared with the lens with the homogeneous equivalent refractive index, the reconstructed GRIN lens has more negative spherical aberration and a larger shift toward more negative values with accommodation. PMID:23927893

  13. Pediatric Amblyopia Risk Investigation Study (PARIS).

    PubMed

    Savage, Howard I; Lee, Hester H; Zaetta, Deneen; Olszowy, Ronald; Hamburger, Ellie; Weissman, Mark; Frick, Kevin

    2005-12-01

    To assess the learning curve, testability, and reliability of vision screening modalities administered by pediatric health extenders. Prospective masked clinical trial. Two hundred subjects aged 3 to 6 underwent timed screening for amblyopia by physician extenders, including LEA visual acuity (LEA), stereopsis (RDE), and noncycloplegic autorefraction (NCAR). Patients returned for a comprehensive diagnostic eye examination performed by an ophthalmologist or optometrist. Average screening time was 5.4 +/- 1.6 minutes (LEA), 1.9 +/- 0.9 minutes (RDE), and 1.7 +/- 1.0 minutes (NCAR). Test time for NCAR and RDE fell by 40% during the study period. Overall testability was 92% (LEA), 96% (RDE), and 94% (NCAR). Testability among 3-year-olds was 73% (LEA), 96% (RDE), and 89% (NCAR). Reliability of LEA was moderate (r = .59). Reliability of NCAR was high for astigmatism (Cyl) (r = .89), moderate for spherical equivalent (SE) (r = .66), and low for anisometropia (ANISO) (r = .38). Correlation of cycloplegic autorefraction (CAR) with gold standard cycloplegic retinoscopic refraction (CRR) was very high for SE (.85), CYL (.77), and moderate for ANISO (.48). With NCAR, physician extenders can quickly and reliably detect astigmatism and spherical refractive error in one-third the time it takes to obtain visual acuity. LEA has a lower initial cost, but is time consuming, moderately reliable, and more difficult for 3-year-olds. Shorter examination time and higher reliability may make NCAR a more efficient screening tool for refractive amblyopia in younger children. Future study is needed to determine the sensitivity and specificity of NCAR and other screening methods in detecting amblyopia and amblyopia risk factors.

  14. Investigating the impact of preoperative corneal astigmatism orientation on the postoperative spherical equivalent refraction following intraocular lens implantation.

    PubMed

    McNeely, Richard N; Moutari, Salissou; Pazo, Eric; Moore, Jonathan E

    2018-01-01

    To investigate the impact of the orientation of preoperative corneal astigmatism on achieving the postoperative target refraction following monofocal intraocular lens (IOL) implantation. This study enrolled 339 eyes who had uneventful cataract surgery or refractive lens exchange (RLE) with subsequent monofocal IOL implantation. Eyes were initially categorized dependent upon axial length and then on the orientation of preoperative anterior corneal astigmatism. Group 1 had against-the-rule (ATR) anterior corneal astigmatism, group 2 had with-the-rule (WTR) anterior corneal astigmatism, and group 3 had oblique (OB) anterior corneal astigmatism. The preoperative corneal astigmatism was determined by the IOLMaster (Carl Zeiss Meditec AG). Postoperative refraction was completed for all eyes, and the results were calculated and compared for the separate groups. In eyes with axial lengths greater than 22.0 mm and less than 25.0 mm there was a significant difference between the magnitude of preoperative corneal astigmatism between groups 2 and 3 with 0.827 ± 0.376 D in group 2, and 0.677 ± 0.387 D in group 3. The mean postoperative spherical equivalent (SE) prediction error was - 0.132 ± 0.475 D in group 1, 0.026 ± 0.497 D in group 2, and - 0.130 ± 0.477 D in group 3. There was a significant difference between groups 1 and 2. There was no significant difference in the magnitude of preoperative corneal astigmatism and postoperative SE prediction error between the anterior corneal astigmatism orientation groups in eyes with axial lengths of less than or equal to 22.0 mm and greater than or equal to 25.0 mm. The orientation of preoperative anterior corneal astigmatism significantly affected the postoperative biometry prediction error in eyes with astigmatism of 1.75 D or less in eyes with the axial length between 22.0 mm and 25.0 mm. However, the results were not clinically significant.

  15. Synthesis characterisation series of newly fabricated type II CdSe CdSe/CdTe nanocrystals and their optical properties

    NASA Astrophysics Data System (ADS)

    Ahmed, A. S.; Christopher, W.

    2018-03-01

    Nanocrystalline semiconductors exhibit different properties due to two basic factors. They possess high surface to volume ratio and the actual size of particle can determine the electronic and physical properties of the material. The small size results in an observable quantum confinement effect, defined by the increasing bandgap accompanied by the quantization of the energy levels to discrete values. In present work we have synthesized the series of cadmium selenide/cadmium telluride (CdSe/CdTe) core/shell and CdSe/CdTe/CdS core/shell/shell to investigate the biexciton energy through transient absorption measurements. These structures are type II nanocrystals are with a hole in the shell and the electron confined to the core. We specifically investigate the effect of nanoparticle shape on the electronic structure and ultrafast electronic dynamics in the band-edge exciton states of CdSe quantum dots, nanorods, and nanoplatelets. Particle size was chosen to enable straightforward comparisons of the effects of particle shape on the spectra and dynamics without retuning the laser source. In our results the Uv-vis showed only a mild redshift in the first excitonic an elongated tail with increasing shell thickness. High resolution Transmission Electron Microscopy (HRTEM) shows the slight agglomeration of the nanocrystals but still the size distribution was calculate able. Spherical small crystals ranging from 5.9 nm to 10 nm are observed. CdTe/CdSe structures were quasi spherical with a rough diameter 6 nm with some little agglomerated structure. . The spherical nanocrystals could be peanut shaped oriented along the c axis or the spherical only, which could explain the two peak emission. p-XRD results indicate the predominant wurtzite structure throughout.

  16. Heritability of myopia and ocular biometrics in Koreans: the healthy twin study.

    PubMed

    Kim, Myung Hun; Zhao, Di; Kim, Woori; Lim, Dong-Hui; Song, Yun-Mi; Guallar, Eliseo; Cho, Juhee; Sung, Joohon; Chung, Eui-Sang; Chung, Tae-Young

    2013-05-01

    To estimate the heritabilities of myopia and ocular biometrics among different family types among a Korean population. We studied 1508 adults in the Healthy Twin Study. Spherical equivalent, axial length, anterior chamber depth, and corneal astigmatism were measured by refraction, corneal topography, and A-scan ultrasonography. To see the degree of resemblance among different types of family relationships, intraclass correlation coefficients (ICC) were calculated. Variance-component methods were applied to estimate the genetic contributions to eye phenotypes as heritability based on the maximum likelihood estimation. Narrow sense heritability was calculated as the proportion of the total phenotypic variance explained by additive genetic effects, and linear and nonlinear effects of age, sex, and interactions between age and sex were adjusted. A total of 240 monozygotic twin pairs, 45 dizygotic twin pairs, and 938 singleton adult family members who were first-degree relatives of twins in 345 families were included in the study. ICCs for spherical equivalent from monozygotic twins, pooled first-degree pairs, and spouse pairs were 0.83, 0.34, and 0.20, respectively. The ICCs of other ocular biometrics were also significantly higher in monozygotic twins compared with other relative pairs, with greater consistency and conformity. The estimated narrow sense heritability (95% confidence interval) was 0.78 (0.71-0.84) for spherical equivalent; 0.86 (0.82-0.90) for axial length; 0.83 (0.76-0.91) for anterior chamber depth; and 0.70 (0.63-0.77) for corneal astigmatism. The estimated heritability of spherical equivalent and ocular biometrics in the Korean population suggests the compelling evidence that all traits are highly heritable.

  17. Heritability of refractive error and ocular biometrics: the Genes in Myopia (GEM) twin study.

    PubMed

    Dirani, Mohamed; Chamberlain, Matthew; Shekar, Sri N; Islam, Amirul F M; Garoufalis, Pam; Chen, Christine Y; Guymer, Robyn H; Baird, Paul N

    2006-11-01

    A classic twin study was undertaken to assess the contribution of genes and environment to the development of refractive errors and ocular biometrics in a twin population. A total of 1224 twins (345 monozygotic [MZ] and 267 dizygotic [DZ] twin pairs) aged between 18 and 88 years were examined. All twins completed a questionnaire consisting of a medical history, education, and zygosity. Objective refraction was measured in all twins, and biometric measurements were obtained using partial coherence interferometry. Intrapair correlations for spherical equivalent and ocular biometrics were significantly higher in the MZ than in the DZ twin pairs (P < 0.05), when refraction was considered as a continuous variable. A significant gender difference in the variation of spherical equivalent and ocular biometrics was found (P < 0.05). A genetic model specifying an additive, dominant, and unique environmental factor that was sex limited was the best fit for all measured variables. Heritability of spherical equivalents of 88% and 75% were found in the men and women, respectively, whereas, that of axial length was 94% and 92%, respectively. Additive genetic effects accounted for a greater proportion of the variance in spherical equivalent, whereas the variance in ocular biometrics, particularly axial length was explained mostly by dominant genetic effects. Genetic factors, both additive and dominant, play a significant role in refractive error (myopia and hypermetropia) as well as in ocular biometrics, particularly axial length. The sex limitation ADE model (additive genetic, nonadditive genetic, and environmental components) provided the best-fit genetic model for all parameters.

  18. Myopia correction in children: a meta-analysis.

    PubMed

    Cui, Yanhui; Li, Li; Wu, Qian; Zhao, Junyang; Chu, Huihui; Yu, Gang; Wei, Wenbin

    2017-06-26

    The purpose of this study was to conduct a meta-analysis comparing rigid gas permeable lenses (RGP) with soft contact lenses (SCL), spectacles and orthokeratology (OK) lenses for myopia control with respect to axial length elongation, spherical equivalent and measures of corneal curvature. Medline, Cochrane, EMBASE, and Google Scholar databases were searched to September 29, 2015 using the following keywords: rigid gas permeable contact lens; refractive error; and refractive abnormalities. Randomized controlled trials, two-arm prospective studies and retrospective studies of children with myopia treated with RGP lenses compared with spectacles, SCL, and OK lenses were included. Outcome measures were changes of axial length, spherical equivalent, flatter meridian, steeper meridian and corneal apical radius. Five studies were included. Three studies reported axial length change after 2-3 years of treatment with RGP lenses and SCL/spectacles and no difference between the groups was noted (pooled mean difference = -0.077, 95% confidence interval [CI]: -0.120 to 0.097, p = 0.840). Two studies reported a change of spherical equivalent after 2-3 years of treatment with RGP lenses and SCL/spectacles, and no difference between the groups was noted (pooled mean difference = 0.275, 95% CI: -0.390 to 0.941, p = 0.417). Two studies compared corneal curvature measures between RGP and OK lenses after 3-6 months of treatment and no differences in any measures of corneal curvature were seen. The effect of RGP lenses and SCL/spectacles on axial length elongation and spherical equivalent and of RGP and OK lenses on corneal curvature in children with myopia was similar.

  19. Determination of shift in energy of band edges and band gap of ZnSe spherical quantum dot

    NASA Astrophysics Data System (ADS)

    Siboh, Dutem; Kalita, Pradip Kumar; Sarma, Jayanta Kumar; Nath, Nayan Mani

    2018-04-01

    We have determined the quantum confinement induced shifts in energy of band edges and band gap with respect to size of ZnSe spherical quantum dot employing an effective confinement potential model developed in our earlier communication "arXiv:1705.10343". We have also performed phenomenological analysis of our theoretical results in comparison with available experimental data and observe a very good agreement in this regard. Phenomenological success achieved in this regard confirms validity of the confining potential model as well as signifies the capability and applicability of the ansatz for the effective confining potential to have reasonable information in the study of real nano-structured spherical systems.

  20. Genome-wide association study for refractive astigmatism reveals genetic co-determination with spherical equivalent refractive error: the CREAM consortium.

    PubMed

    Li, Qing; Wojciechowski, Robert; Simpson, Claire L; Hysi, Pirro G; Verhoeven, Virginie J M; Ikram, Mohammad Kamran; Höhn, René; Vitart, Veronique; Hewitt, Alex W; Oexle, Konrad; Mäkelä, Kari-Matti; MacGregor, Stuart; Pirastu, Mario; Fan, Qiao; Cheng, Ching-Yu; St Pourcain, Beaté; McMahon, George; Kemp, John P; Northstone, Kate; Rahi, Jugnoo S; Cumberland, Phillippa M; Martin, Nicholas G; Sanfilippo, Paul G; Lu, Yi; Wang, Ya Xing; Hayward, Caroline; Polašek, Ozren; Campbell, Harry; Bencic, Goran; Wright, Alan F; Wedenoja, Juho; Zeller, Tanja; Schillert, Arne; Mirshahi, Alireza; Lackner, Karl; Yip, Shea Ping; Yap, Maurice K H; Ried, Janina S; Gieger, Christian; Murgia, Federico; Wilson, James F; Fleck, Brian; Yazar, Seyhan; Vingerling, Johannes R; Hofman, Albert; Uitterlinden, André; Rivadeneira, Fernando; Amin, Najaf; Karssen, Lennart; Oostra, Ben A; Zhou, Xin; Teo, Yik-Ying; Tai, E Shyong; Vithana, Eranga; Barathi, Veluchamy; Zheng, Yingfeng; Siantar, Rosalynn Grace; Neelam, Kumari; Shin, Youchan; Lam, Janice; Yonova-Doing, Ekaterina; Venturini, Cristina; Hosseini, S Mohsen; Wong, Hoi-Suen; Lehtimäki, Terho; Kähönen, Mika; Raitakari, Olli; Timpson, Nicholas J; Evans, David M; Khor, Chiea-Chuen; Aung, Tin; Young, Terri L; Mitchell, Paul; Klein, Barbara; van Duijn, Cornelia M; Meitinger, Thomas; Jonas, Jost B; Baird, Paul N; Mackey, David A; Wong, Tien Yin; Saw, Seang-Mei; Pärssinen, Olavi; Stambolian, Dwight; Hammond, Christopher J; Klaver, Caroline C W; Williams, Cathy; Paterson, Andrew D; Bailey-Wilson, Joan E; Guggenheim, Jeremy A

    2015-02-01

    To identify genetic variants associated with refractive astigmatism in the general population, meta-analyses of genome-wide association studies were performed for: White Europeans aged at least 25 years (20 cohorts, N = 31,968); Asian subjects aged at least 25 years (7 cohorts, N = 9,295); White Europeans aged <25 years (4 cohorts, N = 5,640); and all independent individuals from the above three samples combined with a sample of Chinese subjects aged <25 years (N = 45,931). Participants were classified as cases with refractive astigmatism if the average cylinder power in their two eyes was at least 1.00 diopter and as controls otherwise. Genome-wide association analysis was carried out for each cohort separately using logistic regression. Meta-analysis was conducted using a fixed effects model. In the older European group the most strongly associated marker was downstream of the neurexin-1 (NRXN1) gene (rs1401327, P = 3.92E-8). No other region reached genome-wide significance, and association signals were lower for the younger European group and Asian group. In the meta-analysis of all cohorts, no marker reached genome-wide significance: The most strongly associated regions were, NRXN1 (rs1401327, P = 2.93E-07), TOX (rs7823467, P = 3.47E-07) and LINC00340 (rs12212674, P = 1.49E-06). For 34 markers identified in prior GWAS for spherical equivalent refractive error, the beta coefficients for genotype versus spherical equivalent, and genotype versus refractive astigmatism, were highly correlated (r = -0.59, P = 2.10E-04). This work revealed no consistent or strong genetic signals for refractive astigmatism; however, the TOX gene region previously identified in GWAS for spherical equivalent refractive error was the second most strongly associated region. Analysis of additional markers provided evidence supporting widespread genetic co-susceptibility for spherical and astigmatic refractive errors.

  1. Eighteen-year follow-up of hyperopic photorefractive keratectomy.

    PubMed

    Wagh, Vijay K; Dave, Reena; O'Brart, David P S; Lim, Wei S; Patel, Parul; Tam, Connan; Lee, Jennifer; Marshall, John

    2016-02-01

    To investigate the long-term efficacy of hyperopic photorefractive keratectomy (PRK). University Hospital, London, United Kingdom. Prospective case series. Patients with a follow-up of 18 years ± 0.7 (SD) attended for examination. All had spherical corrections with a 6.5 mm optical zone and 1.5 mm blend zone. Twenty-five patients (45 eyes) were included. The mean preoperative spherical equivalent (SE) refractive error was +4.11 ± 1.8 diopters (D) (range +1.125 to +7.25 D). Between 1 year and 18 years, in eyes that had no cataract surgery (n = 34), there was a +1.14 ± 1.48 D increase in the mean SE (P < .0002). The increase between 7.5 years and 18.0 years did not reach clinical significance (P = .1). Uncorrected distance visual acuity improved at 18 years (P < .02). Corrected distance visual acuity (CDVA) was reduced (P < .001). The efficacy index was 0.47, and the safety index was 0.83. Six eyes (18%) lost 2 lines of CDVA, of which 4 eyes had preexisting cataract. Keratometry remained stable between 1 year and 18 years (P = .2). Forty percent still had traces of peripheral haze, and 4 (9%) had Salzmann-like changes. Eleven eyes (24%) had cataract surgery and 4 (9%) had laser iridotomy. There was no evidence of ectasia. Hyperopic PRK showed an increase in hyperopic SE between 1.0 year and 7.5 years but was generally stable thereafter. The efficacy was limited. Peripheral haze was evident in 40% of cases with Salzmann-like changes in some. Ocular comorbidity in relationship to cataract was common and reduced CDVA. Dr. Marshall was a consultant to Summit Technology, Inc. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  2. Femtosecond (FS) laser vision correction procedure for moderate to high myopia: a prospective study of ReLEx(®) flex and comparison with a retrospective study of FS-laser in situ keratomileusis.

    PubMed

    Vestergaard, Anders; Ivarsen, Anders; Asp, Sven; Hjortdal, Jesper Ø

    2013-06-01

    To present our initial clinical experience with ReLEx(®) flex (ReLEx) for moderate to high myopia. We compare efficacy, safety and corneal higher-order aberrations after ReLEx with femtosecond laser in situ keratomileusis (FS-LASIK). Prospective study of ReLEx compared with a retrospective study of FS-LASIK. ReLEx is a new keratorefractive procedure, where a stromal lenticule is cut by a femtosecond laser and manually extracted. Forty patients were treated with ReLEx on both eyes. A comparable group of 41 FS-LASIK patients were retrospectively identified. Visual acuity, spherical equivalent (SE) and corneal tomography were measured before and 3 months after surgery. Preoperative SE averaged -7.50 ± 1.16 D (ReLEx) and -7.32 ± 1.09 D (FS-LASIK). For all eyes, mean corrected distance visual acuity remained unchanged in both groups. For eyes with emmetropia as target refraction, 41% of ReLEx and 61% of FS-LASIK eyes had an uncorrected distance visual acuity of logMAR ≤ 0.10 at day 1 after surgery, increasing to, respectively, 88% and 69% at 3 months. Mean SE was -0.06 ± 0.35 D 3 months after ReLEx and -0.53 ± 0.60 D after FS-LASIK. The proportion of eyes within ±1.00 D after 3 months was 100% (ReLEx) and 85% (FS-LASIK). For a 6.0-mm pupil, corneal spherical aberrations increased significantly less in ReLEx than FS-LASIK eyes. ReLEx is an all-in-one femtosecond laser refractive procedure, and in this study, results were comparable to FS-LASIK. Refractive predictability and corneal aberrations at 3 months seemed better than or equal to FS-LASIK, whereas visual recovery after ReLEx was slower. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.

  3. Refractive errors in a rural Korean adult population: the Namil Study.

    PubMed

    Yoo, Y C; Kim, J M; Park, K H; Kim, C Y; Kim, T-W

    2013-12-01

    To assess the prevalence of refractive errors, including myopia, high myopia, hyperopia, astigmatism, and anisometropia, in rural adult Koreans. We identified 2027 residents aged 40 years or older in Namil-myeon, a rural town in central South Korea. Of 1928 eligible residents, 1532 subjects (79.5%) participated. Each subject underwent screening examinations including autorefractometry, corneal curvature measurement, and best-corrected visual acuity. Data from 1215 phakic right eyes were analyzed. The prevalence of myopia (spherical equivalent (SE) <-0.5 diopters (D)) was 20.5% (95% confidence interval (CI): 18.2-22.8%), of high myopia (SE <-6.0 D) was 1.0% (95% CI: 0.4-1.5%), of hyperopia (SE>+0.5 D) was 41.8% (95% CI: 38.9-44.4%), of astigmatism (cylinder <-0.5 D) was 63.7% (95% CI: 61.0-66.4%), and of anisometropia (difference in SE between eyes >1.0 D) was 13.8% (95% CI: 11.9-15.8%). Myopia prevalence decreased with age and tended to transition into hyperopia with age up to 60-69 years. In subjects older than this, the trend in SE refractive errors reversed with age. The prevalence of astigmatism and anisometropia increased consistently with age. The refractive status was not significantly different between males and females. The prevalence of myopia and hyperopia in rural adult Koreans was similar to that of rural Chinese. The prevalence of high myopia was lower in this Korean sample than in other East Asian populations, and astigmatism was the most frequently occurring refractive error.

  4. Changes in biomechanical properties of the cornea and intraocular pressure after myopic laser in situ keratomileusis using a femtosecond laser for flap creation determined using ocular response analyzer and Goldmann applanation tonometry.

    PubMed

    Shin, Jonghoon; Kim, Tae Won; Park, Soo Jeong; Yoon, Min; Lee, Ji Woong

    2015-03-01

    To compare intraocular pressure (IOP) measurements before and after laser in situ keratomileusis (LASIK) using a femtosecond laser for flap creation, and to identify factors that may influence the preoperative and postoperative IOP, and the change in IOP after LASIK. Forty eyes from 20 patients who underwent treatment for myopia using a femtosecond laser for flap creation were enrolled in this study. The IOP and corneal biomechanical markers were prospectively measured preoperatively and 1 month after LASIK with Goldmann applanation tonometry (GAT) and the ocular response analyzer (ORA). Manifest refraction spherical equivalent, central corneal thickness, ablation depth, and mean corneal curvature (K reading) were also recorded. After LASIK, there was a significant reduction in the IOP measurement with respect to the corneal-compensated intraocular pressure (IOPcc) (Δ=-0.67±2.07 mm Hg), Goldmann-correlated pressure (IOPg) (Δ=-3.92±2.19 mm Hg), and GAT (Δ=-2.6±2.51). Multiple regression analysis revealed that the corneal hysteresis (CH) and corneal resistance factor (CRF) are statistically significant predictors of IOPcc, IOPg, and GAT (P<0.000). In this analysis, the preoperative manifest refraction spherical equivalent, CH, and CRF were significant predictors of ΔIOPcc (adjusted R²=0.401) and ΔIOPg (adjusted R²=0.386). The preoperative SE and central corneal thickness significantly predicted ΔGAT (adjusted R²=0.464). ORA provides a more complete measurement of IOP after LASIK with a femtosecond laser than GAT because ORA provides greater knowledge of the corneal biomechanics in terms of CH and CRF.

  5. Wavefront-optimized laser in situ keratomileusis with the Allegretto Wave Eye-Q excimer laser and the FEMTO LDV Crystal Line femtosecond laser: 6 month visual and refractive results.

    PubMed

    Ziaei, Mohammed; Mearza, Ali A; Allamby, David

    2015-08-01

    To present the first reported series of patients undergoing myopic LASIK with the FEMTO LDV Crystal Line femtosecond laser and the WaveLight Allegretto Eye-Q excimer laser. We report the uncorrected and corrected distance visual acuity (UDVA and CDVA), refractive predictability, efficacy and safety of laser in situ keratomileusis (LASIK) performed with the above laser platforms. This prospective interventional case series study evaluated consecutive eyes with low to moderate myopic astigmatism that underwent LASIK with the FEMTO LDV Crystal Line femtosecond laser and the WaveLight Allegretto Eye-Q 400 Hz excimer laser. Visual and refractive changes as well as complications were evaluated after wavefront-optimized laser treatment. Four hundred and forty four patients (887 eyes) reached the 6-month time gate. Mean age at time of procedure was 31 years (range: 20-59). Mean pre-op spherical-equivalent (SE) was -3.44 diopters (D)±1.34D (range: -0.50 to -7.00) whilst the postoperative spherical equivalent decreased to -0.08±0.31D (range -2.25 to 1.00). At 6-month follow up, 96.9% of patients had monocular uncorrected distance visual acuity of 20/20 or better with 95.2% of patients within ±0.5D of intended refractive outcome. All patients achieved 20/20 binocular distance uncorrected visual acuity. No significant intra-operative or postoperative complications were encountered during the 6-month follow-up period. The combination of the above laser platforms provides safe, effective and predictable results in correcting compound myopic astigmatism with excellent visual outcomes. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  6. Inertial migrations of cylindrical particles in rectangular microchannels: Variations of equilibrium positions and equivalent diameters

    NASA Astrophysics Data System (ADS)

    Su, Jinghong; Chen, Xiaodong; Hu, Guoqing

    2018-03-01

    Inertial migration has emerged as an efficient tool for manipulating both biological and engineered particles that commonly exist with non-spherical shapes in microfluidic devices. There have been numerous studies on the inertial migration of spherical particles, whereas the non-spherical particles are still largely unexplored. Here, we conduct three-dimensional direct numerical simulations to study the inertial migration of rigid cylindrical particles in rectangular microchannels with different width/height ratios under the channel Reynolds numbers (Re) varying from 50 to 400. Cylindrical particles with different length/diameter ratios and blockage ratios are also concerned. Distributions of surface force with the change of rotation angle show that surface stresses acting on the particle end near the wall are the major contributors to the particle rotation. We obtain lift forces experienced by cylindrical particles at different lateral positions on cross sections of two types of microchannels at various Re. It is found that there are always four stable equilibrium positions on the cross section of a square channel, while the stable positions are two or four in a rectangular channel, depending on Re. By comparing the equilibrium positions of cylindrical particles and spherical particles, we demonstrate that the equivalent diameter of cylindrical particles monotonously increases with Re. Our work indicates the influence of a non-spherical shape on the inertial migration and can be useful for the precise manipulation of non-spherical particles.

  7. Refractive error at birth and its relation to gestational age.

    PubMed

    Varughese, Sara; Varghese, Raji Mathew; Gupta, Nidhi; Ojha, Rishikant; Sreenivas, V; Puliyel, Jacob M

    2005-06-01

    The refractive status of premature infants is not well studied. This study was done to find the norms of refractive error in newborns at different gestational ages. One thousand two hundred three (1203) eyes were examined for refractive error by streak retinoscopy within the first week of life between June 2001 and September 2002. Tropicamide eye drops (0.8%) with phenylephrine 0.5% were used to achieve cycloplegia and mydriasis. The refractive error was measured in the vertical and horizontal meridia in both eyes and was recorded to the nearest dioptre (D). The neonates were grouped in five gestational age groups ranging from 24 weeks to 43 weeks. Extremely preterm babies were found to be myopic with a mean MSE (mean spherical equivalent) of -4.86 D. The MSE was found to progressively decrease (become less myopic) with increasing gestation and was +2.4 D at term. Astigmatism of more than 1 D spherical equivalent was seen in 67.8% of the eyes examined. Among newborns with > 1 D of astigmatism, the astigmatism was with-the-rule (vertical meridian having greater refractive power than horizontal) in 85% and against-the-rule in 15%. Anisometropia of more than 1 D spherical equivalent was seen in 31% babies. Term babies are known to be hypermetropic, and preterm babies with retinopathy of prematurity (ROP) are known to have myopia. This study provides data on the mean spherical equivalent, the degree of astigmatism, and incidence of anisometropia at different gestational ages. This is the largest study in world literature looking at refractive errors at birth against gestational age. It should help understand the norms of refractive errors in preterm babies.

  8. Serum 25-hydroxyvitamin D level is associated with myopia in the Korea national health and nutrition examination survey.

    PubMed

    Kwon, Jin-Woo; Choi, Jin A; La, Tae Yoon

    2016-11-01

    The aim of this article was to assess the associations of serum 25-hydroxyvitamin D [25(OH)D] and daily sun exposure time with myopia in Korean adults.This study is based on the Korea National Health and Nutrition Examination Survey (KNHANES) of Korean adults in 2010-2012; multiple logistic regression analyses were performed to examine the associations of serum 25(OH)D levels and daily sun exposure time with myopia, defined as spherical equivalent ≤-0.5D, after adjustment for age, sex, household income, body mass index (BMI), exercise, intraocular pressure (IOP), and education level. Also, multiple linear regression analyses were performed to examine the relationship between serum 25(OH)D levels with spherical equivalent after adjustment for daily sun exposure time in addition to the confounding factors above.Between the nonmyopic and myopic groups, spherical equivalent, age, IOP, BMI, waist circumference, education level, household income, and area of residence differed significantly (all P < 0.05). Compared with subjects with daily sun exposure time <2 hour, subjects with sun exposure time ≥2 to <5 hour, and those with sun exposure time ≥5 hour had significantly less myopia (P < 0.001). In addition, compared with subjects were categorized into quartiles of serum 25(OH)D, the higher quartiles had gradually lower prevalences of myopia after adjustment for confounding factors (P < 0.001). In multiple linear regression analyses, spherical equivalent was significantly associated with serum 25(OH)D concentration after adjustment for confounding factors (P = 0.002).Low serum 25(OH)D levels and shorter daily sun exposure time may be independently associated with a high prevalence of myopia in Korean adults. These data suggest a direct role for vitamin D in the development of myopia.

  9. Five-year change in refraction and its ocular components in the 40- to 64-year-old population of the Shahroud eye cohort study.

    PubMed

    Hashemi, Hassan; Khabazkhoob, Mehdi; Iribarren, Rafael; Emamian, Mohammad Hassan; Fotouhi, Akbar

    2016-11-01

    To assess 5-year refractive changes and their related factors in the 40- to 64-year-old population of Shahroud, Iran. Prospective cohort study. Of the 5190 participants of Phase I, 4737 participated in Phase II (response rate = 91.3%). Participants were tested by refraction, visual acuity, slit-lamp biomicroscopy, ophthalmoscopy and biometry. Myopia was defined as a spherical equivalent more negative than -0.5 dioptre (D) and hyperopia as a spherical equivalent more positive than +0.5 D. Mean 5-year change in spherical equivalent refraction. The mean 5-year change in spherical equivalent refraction was +0.24 D (95% CI: +0.22 to +0.25). After 5 years, 4.77% (95% CI: 4.08 to 5.46) of subjects developed at least 0.5 D of myopia and 22.27% (95% CI: 20.97 to 23.57) developed at least 0.5 D of hyperopia. Five-year changes in refraction included a hyperopic shift in all age groups. The greatest hyperopic shift was seen in middle-aged women. The greatest loss of lens power was observed in hyperopic women and the least in myopic men. Nuclear cataract was associated with a myopic shift in refraction. The axial length and the corneal power had very small changes during this period. Myopes showed the greatest increase in axial length. Corneal power increased by a very small amount in all refractive groups. The most important biometric index related to hyperopic shifts, which were greater in magnitude in women, was loss of lens power, whereas nuclear cataract was associated with myopic shifts. © 2016 Royal Australian and New Zealand College of Ophthalmologists.

  10. Retinal sensitivity and choroidal thickness in high myopia.

    PubMed

    Zaben, Ahmad; Zapata, Miguel Á; Garcia-Arumi, Jose

    2015-03-01

    To estimate the association between choroidal thickness in the macular area and retinal sensitivity in eyes with high myopia. This investigation was a transversal study of patients with high myopia, all of whom had their retinal sensitivity measured with macular integrity assessment microperimetry. The choroidal thicknesses in the macular area were then measured by optical coherence tomography, and statistical correlations between their functionality and the anatomical structuralism, as assessed by both types of measurements, were analyzed. Ninety-six eyes from 77 patients with high myopia were studied. The patients had a mean age ± standard deviation of 38.9 ± 13.2 years, with spherical equivalent values ranging from -6.00 diopter to -20.00 diopter (8.74 ± 2.73 diopter). The mean central choroidal thickness was 159.00 ± 50.57. The mean choroidal thickness was directly correlated with sensitivity (r = 0.306; P = 0.004) and visual acuity but indirectly correlated with the spherical equivalent values and patient age. The mean sensitivity was not significantly correlated with the macular foveal thickness (r = -0.174; P = 0.101) or with the overall macular thickness (r = 0.103; P = 0.334); furthermore, the mean sensitivity was significantly correlated with visual acuity (r = 0.431; P < 0.001) and the spherical equivalent values (r = -0.306; P = 0.003). Retinal sensitivity in highly myopic eyes is directly correlated with choroidal thickness and does not seem to be associated with retinal thickness. Thus, in patients with high myopia, accurate measurements of choroidal thickness may provide more accurate information about this pathologic condition because choroidal thickness correlates to a greater degree with the functional parameters, patient age, and spherical equivalent values.

  11. A method for the prescription of inexpensive spectacles by non-specialist healthcare workers: S-Glasses

    PubMed Central

    Treacy, M P; Treacy, M G; Dimitrov, B D; Seager, F E; Stamp, M A; Murphy, C C

    2013-01-01

    Purpose Globally, 153 million people are visually impaired from uncorrected refractive error. The aim of this research was to verify a method whereby autorefractors could be used by non-specialist health-workers to prescribe spectacles, which used a small stock of preformed lenses that fit frames with standardised apertures. These spectacles were named S-Glasses (Smart Glasses). Patients and methods This prospective, single-cohort exploratory study enrolled 53 patients with 94 eligible eyes having uncorrected vision of 6/18 or worse. Eyes with best-corrected vision worse than 6/12 were excluded. An autorefractor was used to obtain refractions, which were adjusted so that eyes with astigmatism less than 2.00 dioptres (D) received spherical equivalent lenses, and eyes with more astigmatism received toric lenses with a 2.50 D cylindrical element set at one of four meridians. The primary outcome was to compare S-Glasses vision with the WHO definition of visual impairment (6/18). Where astigmatism was 2.00 D or greater, comparison with spherical equivalent was made. Mixed-model analysis with repeated effect was used to account for possible correlation between the vision of fellow eyes of the same individual. Results S-Glasses corrected 100% of eyes with astigmatism less than 3.00 D and 69% of eyes with astigmatism of 3.00 D or greater. Spherical equivalent lenses corrected 25% of eyes with astigmatism of 2.00−2.99 D and 11% with astigmatism of at least 3.00 D. Discussion S-Glasses could be beneficial to resource-poor populations without trained refractionists. This novel approach, using approximate toric lenses, results in superior vision for astigmatic patients compared with the practice of providing spherical equivalent alone. PMID:23306732

  12. Effect of vitreous length and trephine size disparity on post-DALK refractive status.

    PubMed

    Javadi, Mohammad Ali; Feizi, Sepehr; Rastegarpour, Ali

    2011-04-01

    To evaluate the effect of vitreous length (distance between posterior lens surface and vitreoretinal interface) and donor-recipient disparity on the refraction and keratometric astigmatism after deep anterior lamellar keratoplasty (DALK). In this retrospective comparative study, 85 eyes of 83 patients with keratoconus underwent DALK using the big-bubble technique. A 0.25-mm oversize donor was used for a vitreous length of ≥ 16.0 mm, and a 0.50-mm oversize donor for a vitreous length of <16.0 mm. At least 3 months after complete suture removal, spherical equivalent refractive error (SE), keratometric astigmatism, and mean keratometry were compared between the 2 groups. Multiple regression analysis was performed in group 1 to investigate the correlation between vitreous length and SE, between vitreous length and keratometric astigmatism, and between mean keratometry and SE. Mean patient age was 26.5 ± 7.7 years, and they were followed for 22 ± 10 months postoperatively. Seventy-five eyes received a 0.25-mm oversize donor (group 1), and 10 had a donor oversized by 0.50 mm (group 2). Compared with group 1, the patients of group 2 had a significantly steeper cornea (46.83 ± 2.0 vs. 48.29 ± 1.9 diopters, respectively; P = 0.01). SE and keratometric astigmatism in group 1 did not significantly differ from those in group 2. In group 1, there was a significant association between vitreous length and SE and between mean keratometry and SE but not between vitreous length and keratometric astigmatism. In DALK, a donor oversized by 0.25 mm is advisable for elongated keratoconic eyes, whereas a 0.50-mm oversize donor is advocated for small ones.

  13. Femtosecond-assisted laser in situ keratomileusis for consecutive hyperopia after radial keratotomy.

    PubMed

    Leccisotti, Antonio; Fields, Stefania V

    2015-08-01

    To evaluate femtosecond-assisted laser in situ keratomileusis (LASIK) for the treatment of hyperopic shift after radial keratotomy (RK). Private practice, Siena, Italy. Prospective case series. Eyes with a spherical equivalent (SE) of +1.0 diopters (D) to +4.0 D after RK with 6 or 8 incisions had LASIK. The flap (nominal thickness 130 μm) was created with a femtosecond laser (LDV Z2); the refractive ablation was performed with an excimer laser (217P). The flap was dissected in a centrifugal fashion along previous RK cuts. Eighteen eyes of 10 patients were treated. Preoperatively, the mean defocus equivalent was 3.13 diopters (D) ± 0.71 (SD); the corrected distance visual acuity (CDVA) was 0.09 ± 0.06 logMAR. At 9 months, the mean defocus equivalent was 0.51 ± 0.47 D (P < .05), with 13 eyes (72%) having 0.50 D or less of defocus equivalent and 16 eyes (89%) having 1.0 D or less of defocus equivalent. The mean CDVA was 0.04 ± 0.06 logMAR (P < .05). No lines of logMAR CDVA were lost. The mean uncorrected distance visual acuity was 0.11 ± 0.10 logMAR. The safety index was 1.11; the efficacy index was 0.97. No retreatments were performed. Flap complications were limited to an RK incision opening larger than 2 mm in 3 eyes and 1 case of a small, self-limiting epithelial ingrowth. Laser in situ keratomileusis with a low-energy femtosecond laser was a safe and effective approach to treat post-RK hyperopia, causing no relevant inflammation. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. Effects of temperature and dissolved oxygen on Se(IV) removal and Se(0) precipitation by Shewanella sp. HN-41.

    PubMed

    Lee, Ji-Hoon; Han, Jaehong; Choi, Heechul; Hur, Hor-Gil

    2007-08-01

    Facultative anaerobic Shewanella sp. strain HN-41 was able to utilize selenite (Se(IV)) as a sole electron acceptor for respiration in anaerobic condition, resulting in reduction of Se(IV) and then precipitation of elemental Se nano-sized spherical particles, which were identified using energy-dispersive X-ray spectroscopy and X-ray absorption near-edge structure spectroscopy. When the effects on Se(IV) reduction to elemental Se were studied by varying incubation temperatures and dissolved oxygen contents, Se(IV) reduction occurred more actively with higher removal rate of Se(IV) in aqueous phase and well-shaped spherical Se(0) nanoparticles were formed from the incubations under N(2) (100%) or N(2):O(2) (80%:20%) at 30 degrees C with average diameter values of 181+/-40 nm and 164+/-24 nm, respectively, while relatively less amounts of irregular-shaped Se(0) nanoparticles were produced with negligible amount of Se(IV) reduction and removal under 100% of O(2). The Se particle size distributions based on scanning electron microscopy also showed a general tendency towards decreased Se particle size as oxygen content increased, whereas the particle size seemed uncorrelated to the change in the incubation temperature. These results also suggest that the size-controlled biological Se(0) nanospheres production may be achieved simply by changing the culture conditions.

  15. Comparison of the visual results after SMILE and femtosecond laser-assisted LASIK for myopia.

    PubMed

    Lin, Fangyu; Xu, Yesheng; Yang, Yabo

    2014-04-01

    To perform a comparative clinical analysis of the safety, efficacy, and predictability of two surgical procedures (ie, small incision lenticule extraction [SMILE] and femtosecond laser-assisted LASIK [FS-LASIK]) to correct myopia. Sixty eyes of 31 patients with a mean spherical equivalent of -5.13 ± 1.75 diopters underwent myopia correction with the SMILE procedure. Fifty-one eyes of 27 patients with a mean spherical equivalent of -5.58 ± 2.41 diopters were treated with the FS-LASIK procedure. Postoperative uncorrected and corrected distance visual acuity, manifest refraction, and higher-order aberrations were analyzed statistically at 1 and 3 months postoperatively. No statistically significant differences were found at 1 and 3 months in parameters that included the percentage of eyes with an uncorrected distance visual acuity of 20/20 or better (P = .556, .920) and mean spherical equivalent refraction (P = .055, .335). At 1 month, 4 SMILE-treated eyes and 1 FS-LASIK-treated eye lost one or more line of visual acuity (P = .214, chi-square test). At 3 months, 2 SMILE-treated eyes lost one or more line of visual acuity, whereas all FS-LASIK-treated eyes had an unchanged or corrected distance visual acuity. Higher-order aberrations and spherical aberration were significantly lower in the SMILE group than the FS-LASIK group at 1 (P = .007, .000) and 3 (P = .006, .000) months of follow-up. SMILE and FS-LASIK are safe, effective, and predictable surgical procedures to treat myopia. SMILE has a lower induction rate of higher-order aberrations and spherical aberration than the FS-LASIK procedure. Copyright 2014, SLACK Incorporated.

  16. Evaluation of optical performance of 4 aspheric toric intraocular lenses using an optical bench system: Influence of pupil size, decentration, and rotation.

    PubMed

    Kim, Min-Ji; Yoo, Young-Sik; Joo, Choun-Ki; Yoon, Geunyoung

    2015-10-01

    To evaluate the effect of pupil size, degree of intraocular lens (IOL) decentration, and rotation of 4 aspheric toric IOLs on the image quality. Department of Ophthalmology, Seoul St. Mary's Hospital, Seoul, South Korea. Experimental study. Four aspheric toric intraocular lenses (IOLs)-the Precizon (transitional conic toric IOL), AT Torbi 709M (bitoric IOL), SN6AT4 (posterior toric surface IOL), and ZCT225 (anterior toric surface IOL)-were evaluated using the optical bench metrology system. Measurements included changes in spherical aberrations, relative spherical equivalent (SE), and image quality at different pupil diameters and image quality degradation due to decentration and rotation of the IOLs. Change in relative SE with pupil size in aberration-free toric IOLs (transitional conic toric and bitoric IOLs) was greater than in negatively aspheric toric IOLs (posterior toric surface and anterior toric surface IOLs). In contrast, the aberration-free IOLs showed higher contrast than the negatively aspheric IOLs. When IOLs were decentered by 1.0 mm, the contrast reduction rates at 17.6 cycles per degree for the transitional conic toric IOL, bitoric IOL, posterior toric surface IOL, and anterior toric surface IOL were 5.1%, 3.1%, 12.2%, and 15.8%, respectively. Rotation-induced deterioration of contrast to 0.5 required a much higher rotation for the transitional conic toric IOL than for the other 3 IOLs. The transitional conic toric IOL and bitoric IOL provided superior image quality despite pupil size changes and the presence of decentration. The transitional conic toric IOL demonstrated maximum rotation tolerance compared with the other IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. Does the month of birth influence the prevalence of refractive errors?

    PubMed

    Czepita, Maciej; Kuprjanowicz, Leszek; Safranow, Krzysztof; Mojsa, Artur; Majdanik, Ewa; Ustianowska, Maria; Czepita, Damian

    2015-01-01

    The aim of our study was to examine whether the month of birth influences the prevalence of refractive errors. A total of 5,601 schoolchildren were examined (2,688 boys and 2,913 girls, aged 6-18 years, mean age 11.9, SD 3.2 years). The children examined, students of elementary and secondary schools, were Polish and resided in and around Szczecin, Poland. Every examined subject underwent retinoscopy under cycloplegia using 1% tropicamide. Data analysis was performed using the Kruskal-Wallis test followed by the Siegel and Castellan post-hoc test or the Mann-Whitney U-test. P values of < 0.05 were considered statistically significant. Students born in June had significantly higher spherical equivalents than schoolchildren born in May (0.66 ± 1.17 and 0.39 ± 1.17 respectively, p = 0.0058). The Mann-Whitney U-test showed that students born in June had significantly higher spherical equivalents than schoolchildren born in any other month (0.66 ± 1.17 and 0.50 ± 1.17 respectively, p = 0.0033). Besides that, we did not observe any other association between refractive errors and the month of birth. Children born in Poland in June may have a higher spherical equivalent.

  18. A boundary condition to the Khokhlov-Zabolotskaya equation for modeling strongly focused nonlinear ultrasound fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosnitskiy, P., E-mail: pavrosni@yandex.ru; Yuldashev, P., E-mail: petr@acs366.phys.msu.ru; Khokhlova, V., E-mail: vera@acs366.phys.msu.ru

    2015-10-28

    An equivalent source model was proposed as a boundary condition to the nonlinear parabolic Khokhlov-Zabolotskaya (KZ) equation to simulate high intensity focused ultrasound (HIFU) fields generated by medical ultrasound transducers with the shape of a spherical shell. The boundary condition was set in the initial plane; the aperture, the focal distance, and the initial pressure of the source were chosen based on the best match of the axial pressure amplitude and phase distributions in the Rayleigh integral analytic solution for a spherical transducer and the linear parabolic approximation solution for the equivalent source. Analytic expressions for the equivalent source parametersmore » were derived. It was shown that the proposed approach allowed us to transfer the boundary condition from the spherical surface to the plane and to achieve a very good match between the linear field solutions of the parabolic and full diffraction models even for highly focused sources with F-number less than unity. The proposed method can be further used to expand the capabilities of the KZ nonlinear parabolic equation for efficient modeling of HIFU fields generated by strongly focused sources.« less

  19. Analysis of Genetic and Environmental Risk Factors and Their Interactions in Korean Patients with Age-Related Macular Degeneration.

    PubMed

    Woo, Se Joon; Ahn, Jeeyun; Morrison, Margaux A; Ahn, So Yeon; Lee, Jaebong; Kim, Ki Woong; DeAngelis, Margaret M; Park, Kyu Hyung

    2015-01-01

    To investigate the association of genetic and environmental factors, and their interactions in Korean patients with exudative age-related macular degeneration (AMD). A total of 314 robustly characterized exudative AMD patients, including 111 PCV (polypoidal choroidal vasculopathy) and 154 typical choroidal neovascularization (CNV), and 395 control subjects without any evidence of AMD were enrolled. Full ophthalmologic examinations including fluorescein angiography (FA), indocyanine green angiography (ICG) and optical coherence tomography (OCT) were done, according to which patients were divided into either PCV or typical CNV. Standardized questionnaires were used to collect information regarding underlying systemic diseases, dietary habits, smoking history and body mass index (BMI). A total of 86 SNPs from 31 candidate genes were analyzed. Genotype association and logistic regression analyses were done and stepwise regression models to best predict disease for each AMD subtype were constructed. Age, spherical equivalent, myopia, and ever smoking were associated with exudative AMD. Age, hypertension, hyperlipidemia, spherical equivalent, and myopia were risk factors for typical CNV, while increased education and ever smoking were significantly associated with PCV (p<.05 for all). Four SNPs, ARMS2/HTRA1 rs10490924, rs11200638, and rs2736911, and CFH rs800292, showed association with exudative AMD. Two of these SNPs, ARMS2/HTRA1 rs10490924 and rs11200638, showed significant association with typical CNV and PCV specifically. There were no significant interactions between environmental and genetic factors. The most predictive disease model for exudative AMD included age, spherical equivalent, smoking, CFH rs800292, and ARMS2 rs10490924 while that for typical CNV included age, hyperlipidemia, spherical equivalent, and ARMS2 rs10490924. Smoking, spherical equivalent, and ARMS2 rs10490924 were the most predictive variables for PCV. When comparing PCV cases to CNV cases, age, BMI, and education were the most predictive risk factors of PCV. Only one locus, the ARMS2/HTRA1 was a significant genetic risk factor for Korean exudative AMD, including its subtypes, PCV and typical CNV. Stepwise regression revealed that CFH was important to risk of exudative AMD in general but not to any specific subtype. While increased education was a unique risk factor to PCV when compared to CNV, this association was independent of refractive error in this homogenous population from South Korea. No significant interactions between environmental and genetic risk factors were observed.

  20. [Keratoconus special soft contact lens fitting].

    PubMed

    Yamazaki, Ester Sakae; da Silva, Vanessa Cristina Batista; Morimitsu, Vagner; Sobrinho, Marcelo; Fukushima, Nelson; Lipener, César

    2006-01-01

    To evaluate the fitting and use of a soft contact lens in keratoconic patients. Retrospective study on 80 eyes of 66 patients, fitted with a special soft contact lens for keratoconus, at the Contact Lens Section of UNIFESP and private clinics. Keratoconus was classified according to degrees of disease severity by keratometric pattern. Age, gender, diagnosis, keratometry, visual acuity, spherical equivalent (SE), base curve and clinical indication were recorded. Of 66 patients (80 eyes) with keratoconus the mean age was 29 years, 51.5% were men and 48.5% women. According to the groups: 15.0% were incipient, 53.7% moderate, 26.3% advanced and 5.0% were severe. The majority of the eyes of patients using contact lenses (91.25%) achieved visual acuity better than 20/40. To 88 eyes 58% were tihed with lens with spherical power (mean -5.45 diopters) and 41% with spherocylinder power (from -0.5 to -5.00 cylindrical diopters). The most frequent base curve was 7.6 in 61% of the eyes. The main reasons for this special lens fitting were due to reduced tolerance and poor fitting pattern achieved with other lenses. The special soft contact lens is useful in fitting difficult keratoconic patients by offering comfort and improving visual rehabilitation that may allow more patients to postpone the need for corneal transplant.

  1. [Clinical Results of Diffractive Multifocal Intraocular Lens Implantation after Laser In Situ Keratomileusis].

    PubMed

    Yoshino, Mami; Minami, Keiichiro; Hirasawa, Manabu; Oki, Shinichi; Bissen-Miyajima, Hiroko

    2015-09-01

    To evaluate the visual performance in eyes with diffractive intraocular lenses (IOLs) after laser in situ keratomileusis (LASIK). This single-center retrospective study evaluated eyes that had diffractive multifocal IOL implantation after previous LASIK or not treated with LASIK (controls). The outcomes' measures were the visual acuities (VAs) at distance and near, spherical equivalent (SE) and contrast sensitivity at one month postoperatively. The study evaluated 40 eyes of 33 patients. The mean uncorrected logMAR VAs were -0.05 ± 0.13/0.00 ± 0.14 (LASIK group/control group) at distance and 0.10 ± 0.13/0.16 ± 0.18 at near. There was no statistically significant difference between the 2 groups at the VAs. The SE of the LASIK group was -0.06 ± 0.39 D, significantly lower than the control group (0.22 ± 0.45 D) (p < 0.05). The contrast sensitivity of the LASIK group at high spatial frequency was lower than the control group (p < 0.05). After LASIK, the diffractive multifocal IOL provided good uncorrected distance and near VAs. However, decrease in contrast sensitivity should be considered.

  2. Accuracy of noncycloplegic refraction performed at school screening camps.

    PubMed

    Khurana, Rolli; Tibrewal, Shailja; Ganesh, Suma; Tarkar, Rajoo; Nguyen, Phuong Thi Thanh; Siddiqui, Zeeshan; Dasgupta, Shantanu

    2018-06-01

    The aim of this study was to compare noncycloplegic refraction performed in school camp with that performed in eye clinic in children aged 6-16 years. A prospective study of children with unaided vision <0.2 LogMAR who underwent noncycloplegic retinoscopy (NCR) and subjective refraction (SR) in camp and subsequently in eye clinic between February and March 2017 was performed. A masked optometrist performed refractions in both settings. The agreement between refraction values obtained at both settings was compared using the Bland-Altman analysis. A total of 217 eyes were included in this study. Between the school camp and eye clinic, the mean absolute error ± standard deviation in spherical equivalent (SE) of NCR was 0.33 ± 0.4D and that of SR was 0.26 ± 0.5D. The limits of agreement for NCR were +0.91D to - 1.09D and for SR was +1.15D to -1.06D. The mean absolute error in SE was ≤0.5D in 92.62% eyes (95% confidence interval 88%-95%). A certain degree of variability exists between noncycloplegic refraction done in school camps and eye clinic. It was found to be accurate within 0.5D of SE in 92.62% eyes for refractive errors up to 4.5D of myopia, 3D of cylinder, and 1.5D of hyperopia.

  3. Delayed formation of zero-valent selenium nanoparticles by Bacillus mycoides SeITE01 as a consequence of selenite reduction under aerobic conditions

    PubMed Central

    2014-01-01

    Background Selenite (SeO32−) oxyanion shows severe toxicity to biota. Different bacterial strains exist that are capable of reducing SeO32− to non-toxic elemental selenium (Se0), with the formation of Se nanoparticles (SeNPs). These SeNPs might be exploited for technological applications due to their physico-chemical and biological characteristics. The present paper discusses the reduction of selenite to SeNPs by a strain of Bacillus sp., SeITE01, isolated from the rhizosphere of the Se-hyperaccumulator legume Astragalus bisulcatus. Results Use of 16S rRNA and GyrB gene sequence analysis positioned SeITE01 phylogenetically close to B. mycoides. On agarized medium, this strain showed rhizoid growth whilst, in liquid cultures, it was capable of reducing 0.5 and 2.0 mM SeO32− within 12 and 24 hours, respectively. The resultant Se0 aggregated to form nanoparticles and the amount of Se0 measured was equivalent to the amount of selenium originally added as selenite to the growth medium. A delay of more than 24 hours was observed between the depletion of SeO32 and the detection of SeNPs. Nearly spherical-shaped SeNPs were mostly found in the extracellular environment whilst rarely in the cytoplasmic compartment. Size of SeNPs ranged from 50 to 400 nm in diameter, with dimensions greatly influenced by the incubation times. Different SeITE01 protein fractions were assayed for SeO32− reductase capability, revealing that enzymatic activity was mainly associated with the membrane fraction. Reduction of SeO32− was also detected in the supernatant of bacterial cultures upon NADH addition. Conclusions The selenite reducing bacterial strain SeITE01 was attributed to the species Bacillus mycoides on the basis of phenotypic and molecular traits. Under aerobic conditions, the formation of SeNPs were observed both extracellularly or intracellullarly. Possible mechanisms of Se0 precipitation and SeNPs assembly are suggested. SeO32− is proposed to be enzimatically reduced to Se0 through redox reactions by proteins released from bacterial cells. Sulfhydryl groups on peptides excreted outside the cells may also react directly with selenite. Furthermore, membrane reductases and the intracellular synthesis of low molecular weight thiols such as bacillithiols may also play a role in SeO32− reduction. Formation of SeNPs seems to be the result of an Ostwald ripening mechanism. PMID:24606965

  4. Clinical results of excimer laser photorefractive keratectomy: a multicenter study of 265 eyes.

    PubMed

    Aron-Rosa, D S; Colin, J; Aron, B; Burin, N; Cochener, B; Febraro, J L; Gallinaro, C; Ganem, S; Valdes, R

    1995-11-01

    Efficacy, predictability, and safety of excimer laser photorefractive keratectomy were evaluated at centers in Paris and Brest, France. Photoablation was performed with the VISX laser on 265 eyes (151 at the Paris center and 114 at the Brest center). The eyes were clinically and statistically evaluated over a six month follow-up. Initial myopia ranged from -0.7 to -19.4 diopters (D) (mean spherical equivalent [SE] -5.9 D) in the Paris center and from -0.9 to -14.5 D (SE -4.5 D) in the Brest center. At both centers, the mean uncorrected visual acuity was worse than 20/200; over 90% of cases in each center had a best uncorrected visual acuity of 20/100 or worse. Results are reported globally and for subgroups of myopia: Group A, SE better than or equal to -3.0 D; Group B, SE worse than -3.0 D and better than or equal to -7.0 D; Group C, SE worse than -7.0 D. Uncorrected visual acuity was significantly improved in the patients followed for six months; 64% of Paris cases and 62% of Brest cases obtained an uncorrected visual acuity of 20/40 or better. Predictability of the treatment was good; 67% of Paris eyes and 74% of Brest eyes were less than 1.0 D from the intended correction after six months. The data suggest that the initial myopia affected the efficacy and predictability of the treatment; results in the mild to moderate myopia eyes were significantly better than results in the severe myopia eyes. One case of visual acuity regression (less than one line) was observed in the two groups. This was associated with corneal haze of moderate intensity.

  5. Refractive errors in a rural Korean adult population: the Namil Study

    PubMed Central

    Yoo, Y C; Kim, J M; Park, K H; Kim, C Y; Kim, T-W

    2013-01-01

    Purpose To assess the prevalence of refractive errors, including myopia, high myopia, hyperopia, astigmatism, and anisometropia, in rural adult Koreans. Methods We identified 2027 residents aged 40 years or older in Namil-myeon, a rural town in central South Korea. Of 1928 eligible residents, 1532 subjects (79.5%) participated. Each subject underwent screening examinations including autorefractometry, corneal curvature measurement, and best-corrected visual acuity. Results Data from 1215 phakic right eyes were analyzed. The prevalence of myopia (spherical equivalent (SE) <−0.5 diopters (D)) was 20.5% (95% confidence interval (CI): 18.2−22.8%), of high myopia (SE <−6.0 D) was 1.0% (95% CI: 0.4−1.5%), of hyperopia (SE>+0.5 D) was 41.8% (95% CI: 38.9−44.4%), of astigmatism (cylinder <−0.5 D) was 63.7% (95% CI: 61.0−66.4%), and of anisometropia (difference in SE between eyes >1.0 D) was 13.8% (95% CI: 11.9−15.8%). Myopia prevalence decreased with age and tended to transition into hyperopia with age up to 60−69 years. In subjects older than this, the trend in SE refractive errors reversed with age. The prevalence of astigmatism and anisometropia increased consistently with age. The refractive status was not significantly different between males and females. Conclusions The prevalence of myopia and hyperopia in rural adult Koreans was similar to that of rural Chinese. The prevalence of high myopia was lower in this Korean sample than in other East Asian populations, and astigmatism was the most frequently occurring refractive error. PMID:24037232

  6. Analytical study of the effects of clouds on the light produced by lightning

    NASA Technical Reports Server (NTRS)

    Phanord, Dieudonne D.

    1990-01-01

    Researchers consider the scattering of visible and infrared light due to lightning by cubic, cylindrical and spherical clouds. The researchers extend to cloud physics the work by Twersky for single and multiple scattering of electromagnetic waves. They solve the interior problem separately to obtain the bulk parameters for the scatterer equivalent to the ensemble of spherical droplets. With the interior solution or the equivalent medium approach, the multiple scattering problem is reduced to that of a single scatterer in isolation. Hence, the computing methods of Wiscombe or Bohren specialized to Mie scattering with the possibility for absorption were used to generate numerical results in short computer time.

  7. Influence of refractive condition on retinal vasculature complexity in younger subjects.

    PubMed

    Azemin, Mohd Zulfaezal Che; Daud, Norsyazwani Mohamad; Ab Hamid, Fadilah; Zahari, Ilyanoon; Sapuan, Abdul Halim

    2014-01-01

    The aim of this study was to compare the retinal vasculature complexity between emmetropia, and myopia in younger subjects. A total of 82 patients (24.12 ± 1.25 years) with two types of refractive conditions, myopia and emmetropia were enrolled in this study. Refraction data were converted to spherical equivalent refraction. These retinal images (right eyes) were obtained from NAVIS Lite Image Filing System and the vasculature complexity was measured by fractal dimension (D f ), quantified using a computer software following a standardized protocol. There was a significant difference (P < 0.05) in the value of D f between emmetropic (1.5666 ± 0.0160) and myopic (1.5588 ± 0.0142) groups. A positive correlation (rho = 0.260, P < 0.05) between the D f and the spherical equivalent refraction was detected in this study. Using a linear model, it was estimated that 6.7% of the variation in D f could be explained by spherical equivalent refraction. This study provides valuable findings about the effect of moderate to high myopia on the fractal dimension of the retinal vasculature network. These results show that myopic refraction in younger subjects was associated with a decrease in D f , suggesting a loss of retinal vessel density with moderate to high myopia.

  8. Multiple regression analysis in nomogram development for myopic wavefront laser in situ keratomileusis: Improving astigmatic outcomes.

    PubMed

    Allan, Bruce D; Hassan, Hala; Ieong, Alvin

    2015-05-01

    To describe and evaluate a new multiple regression-derived nomogram for myopic wavefront laser in situ keratomileusis (LASIK). Moorfields Eye Hospital, London, United Kingdom. Prospective comparative case series. Multiple regression modeling was used to derive a simplified formula for adjusting attempted spherical correction in myopic LASIK. An adaptation of Thibos' power vector method was then applied to derive adjustments to attempted cylindrical correction in eyes with 1.0 diopter (D) or more of preoperative cylinder. These elements were combined in a new nomogram (nomogram II). The 3-month refractive results for myopic wavefront LASIK (spherical equivalent ≤11.0 D; cylinder ≤4.5 D) were compared between 299 consecutive eyes treated using the earlier nomogram (nomogram I) in 2009 and 2010 and 414 eyes treated using nomogram II in 2011 and 2012. There was no significant difference in treatment accuracy (variance in the postoperative manifest refraction spherical equivalent error) between nomogram I and nomogram II (P = .73, Bartlett test). Fewer patients treated with nomogram II had more than 0.5 D of residual postoperative astigmatism (P = .0001, Fisher exact test). There was no significant coupling between adjustments to the attempted cylinder and the achieved sphere (P = .18, t test). Discarding marginal influences from a multiple regression-derived nomogram for myopic wavefront LASIK had no clinically significant effect on treatment accuracy. Thibos' power vector method can be used to guide adjustments to the treatment cylinder alongside nomograms designed to optimize postoperative spherical equivalent results in myopic LASIK. mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Coma of modified Gregorian and Cassegrainian mirror systems

    NASA Technical Reports Server (NTRS)

    Jones, R. T.

    1976-01-01

    The equivalence of the classical Newtonian, Cassegrainian, and Gregorian mirror systems with respect to the first two Seidel aberrations is rederived by means of a simple congruence. The effects of arbitrary small modifications of the two mirror systems are then studied and general formulas are derived for the effects of such modifications on the spherical aberration and coma. Spherical aberration is corrected to the third order if the amount of glass removed from one surface is replaced at the corresponding zone of the other surface. Modifications in which one surface is made spherical while the other is adjusted to eliminate spherical aberration result in large increases of coma for systems having the usual amplifying ratios.

  10. Outcomes of LASIK and PRK in previous penetrating corneal transplant recipients.

    PubMed

    Kovoor, Timmy A; Mohamed, Engy; Cavanagh, H Dwight; Bowman, R Wayne

    2009-09-01

    To evaluate the safety and efficacy of excimer laser refractive surgery in correcting refractive error in eyes that have undergone previous penetrating keratoplasty (PK). Twenty-three keratorefractive procedures on 16 eyes from 16 consecutive subjects were evaluated between 2002 and 2008. Each patient presented a previous history of a PK with subsequent postoperative myopia and astigmatism. Keratometric value, manifest refraction, best-corrected visual acuity, uncorrected visual acuity, and complications were determined. There were a total of 14 photorefractive keratectomy (PRK) procedures performed on 11 eyes and 9 laser in situ keratomileusis (LASIK) procedures performed on 5 eyes. In the PRK group, the preoperative post-PK manifest refractive spherical equivalent and cylindrical error were -6.22 +/- 6.23 diopter and 5.23 +/- 2.26 D, respectively. The PRK postoperative manifest refractive spherical equivalent and cylindrical error were -3.61 +/- 4.23 D (P=0.25) and 3.21 +/- 1.78 D (P=0.02), respectively. In the LASIK group, the preoperative post-PK manifest refractive spherical equivalent and cylindrical error were -3.05 +/- 3.29 D and 4.11 +/- 2.38 D, respectively. The LASIK postoperative manifest refractive spherical equivalent and cylindrical error were -1.51 +/- 2.02 D (P=0.24) and 2.08 +/- 1.26 D (P=0.03), respectively. There was a 2-line or greater improvement of uncorrected visual acuity in 8 of the 14 PRK treatments and 5 of the 9 LASIK treatments. There were two episodes of acute graft rejection. One of the episodes resolved with topical and oral corticosteroids, and the other episode required a repeat corneal transplantation. PRK and LASIK are effective tools in reducing surgically induced astigmatism after penetrating corneal transplantation in most patients in this case series. The reduction of astigmatism may allow improved contact lens or spectacle fitting to achieve best-corrected binocular visual acuity.

  11. Reduced vision in highly myopic eyes without ocular pathology: the ZOC-BHVI high myopia study.

    PubMed

    Jong, Monica; Sankaridurg, Padmaja; Li, Wayne; Resnikoff, Serge; Naidoo, Kovin; He, Mingguang

    2018-01-01

    The aim was to investigate the relationship of the magnitude of myopia with visual acuity in highly myopic eyes without ocular pathology. Twelve hundred and ninety-two highly myopic eyes (up to -6.00 DS both eyes, no astigmatic cut-off) with no ocular pathology from the ZOC-BHVI high myopia study in China, had cycloplegic refraction, followed by subjective refraction and visual acuities and axial length measurement. Two logistic regression models were undertaken to test the association of age, gender, refractive error, axial length and parental myopia with reduced vision. Mean group age was 19.0 ± 8.6 years; subjective spherical equivalent refractive error was -9.03 ± 2.73 D; objective spherical equivalent refractive error was -8.90 ± 2.60 D and axial length was 27.0 ± 1.3 mm. Using visual acuity, 82.4 per cent had normal vision, 16.0 per cent had mildly reduced vision, 1.2 per cent had moderately reduced vision, 0.3 per cent had severely reduced vision and no subjects were blind. The percentage with reduced vision increased with spherical equivalent to 74.5 per cent from -15.00 to -39.99 D, axial length to 67.7 per cent of eyes from 30.01 to 32.00 mm and age to 22.9 per cent of those 41 years and over. Spherical equivalent and axial length were significantly associated with reduced vision (p < 0.0001). Age and parental myopia were not significantly associated with reduced vision. Gender was significant for one model (p = 0.04). Mildly reduced vision is common in high myopia without ocular pathology and is strongly correlated with greater magnitudes of refractive error and axial length. Better understanding is required to minimise reduced vision in high myopes. © 2017 Optometry Australia.

  12. Monodispersed spherical shaped selenium nanoparticles (SeNPs) synthesized by Bacillus subtilis and its toxicity evaluation in zebrafish embryos

    NASA Astrophysics Data System (ADS)

    Chandramohan, Subburaman; Sundar, Krishnan; Muthukumaran, Azhaguchamy

    2018-02-01

    Selenium is one of the essential elements involved in antioxidative and antiinflammatory effects in human body. By naturally, selenium ions are metabolised and converted into nano selenium. Now a days there is an increasing attention on applications of nanoparticles in therapeutic field. In the present study Bacillus subtilis was used to convert sodium selenite to SeNPs. The synthesized SeNPs were characterized by Fourier Transform Infrared Spectroscopy (FTIR), X Ray Diffraction (XRD) and Scanning Electron Microscopy (SEM) coupled with Energy Dispersive X ray spectroscopy (EDX). The presence of SeNPs was confirmed by the formation of red colour. The bands were sharp with broad absorption peaks at 3562 cm-1 and 1678-1 cm in FTIR which showed that the bacterial proteins were responsible for the reduction of sodium selenite to SeNPs. The average size of the SeNPs was 334 nm and were spherical in shape with uniform distribution. The XRD data confirmed that SeNPs were of amorphous in nature. The zeta potential of SeNPs was negative in charge which indicated high stability. In the present study zebrafish embryos were used to study the toxicity of SeNPs and the results showed that the concentration beyond 10 μg ml-1 leads to toxic effects in embryos/hatchlings. The lesser concentration of SeNPs can be useful in various biomedical applications.

  13. Modelling the backscatter from spherical cavities in a solid matrix: Can an effective medium layer model mimic the scattering response?

    NASA Astrophysics Data System (ADS)

    Pinfield, Valerie J.; Challis, Richard E.

    2011-01-01

    Industrial applications are increasingly turning to modern composite layered materials to satisfy strength requirements whilst reducing component weight. An important group of such materials are fibre/resin composites in which long fibres are laid down in layers in a resin matrix. Whilst delamination flaws, where layers separate from each other, are detectable using traditional ultrasonic techniques, the presence of porosity in any particular layer is harder to detect. The reflected signal from a layered material can already be modelled successfully by using the acoustic impedance of the layers and summing reflections from layer boundaries. However, it is not yet known how to incorporate porosity into such a model. The aim of the work reported here was to model the backscatter from randomly distributed spherical cavities within one layer, and to establish whether an effective medium, with a derived acoustic impedance, could reproduce the characteristics of that scattering. Since effective medium models are much more readily implemented in simulations of multi-layer structures than scattering per se, it was felt desirable to simplify the scattering response into an effective medium representation. A model was constructed in which spherical cavities were placed randomly in a solid continuous matrix and the system backscattering response was calculated. The scattering from the cavities was determined by using the Rayleigh partial-wave method, and taking the received signal at the transducer to be equivalent to the far field limit. It was concluded that even at relatively low porosity levels, the received signal was still "layer-like" and an effective medium model was a good approximation for the scattering behaviour.

  14. Ocular higher-order aberrations in a school children population.

    PubMed

    Papamastorakis, George; Panagopoulou, Sophia; Tsilimbaris, Militadis K; Pallikaris, Ioannis G; Plainis, Sotiris

    2015-01-01

    The primary objective of the study was to explore the statistics of ocular higher-order aberrations in a population of primary and secondary school children. A sample of 557 children aged 10-15 years were selected from two primary and two secondary schools in Heraklion, Greece. Children were classified by age in three subgroups: group I (10.7±0.5 years), group II (12.4±0.5 years) and group III (14.5±0.5 years). Ocular aberrations were measured using a wavefront aberrometer (COAS, AMO Wavefront Sciences, USA) at mesopic light levels (illuminance at cornea was 4lux). Wavefront analysis was achieved for a 5mm pupil. Statistical analysis was carried out for the right eye only. The average coefficient of most high-order aberrations did not differ from zero with the exception of vertical (0.076μm) and horizontal (0.018μm) coma, oblique trefoil (-0.055μm) and spherical aberration (0.018μm). The most prominent change between the three groups was observed for the spherical aberration, which increased from 0.007μm (SE 0.005) in group I to 0.011μm (SE 0.004) in group II and 0.030μm (SE 0.004) in group III. Significant differences were also found for the oblique astigmatism and the third-order coma aberrations. Differences in the low levels of ocular spherical aberration in young children possibly reflect differences in lenticular spherical aberration and relate to the gradient refractive index of the lens. The evaluation of spherical aberration at certain stages of eye growth may help to better understand the underlying mechanisms of myopia development. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  15. Ocular higher-order aberrations in a school children population

    PubMed Central

    Papamastorakis, George; Panagopoulou, Sophia; Tsilimbaris, Militadis K.; Pallikaris, Ioannis G.; Plainis, Sotiris

    2014-01-01

    Purpose The primary objective of the study was to explore the statistics of ocular higher-order aberrations in a population of primary and secondary school children. Methods A sample of 557 children aged 10–15 years were selected from two primary and two secondary schools in Heraklion, Greece. Children were classified by age in three subgroups: group I (10.7 ± 0.5 years), group II (12.4 ± 0.5 years) and group III (14.5 ± 0.5 years). Ocular aberrations were measured using a wavefront aberrometer (COAS, AMO Wavefront Sciences, USA) at mesopic light levels (illuminance at cornea was 4 lux). Wavefront analysis was achieved for a 5 mm pupil. Statistical analysis was carried out for the right eye only. Results The average coefficient of most high-order aberrations did not differ from zero with the exception of vertical (0.076 μm) and horizontal (0.018 μm) coma, oblique trefoil (−0.055 μm) and spherical aberration (0.018 μm). The most prominent change between the three groups was observed for the spherical aberration, which increased from 0.007 μm (SE 0.005) in group I to 0.011 μm (SE 0.004) in group II and 0.030 μm (SE 0.004) in group III. Significant differences were also found for the oblique astigmatism and the third-order coma aberrations. Conclusions Differences in the low levels of ocular spherical aberration in young children possibly reflect differences in lenticular spherical aberration and relate to the gradient refractive index of the lens. The evaluation of spherical aberration at certain stages of eye growth may help to better understand the underlying mechanisms of myopia development. PMID:25288226

  16. Macular pigment optical density and its relationship with refractive status and foveal thickness in Chinese school-aged children.

    PubMed

    Zheng, Wenjing; Zhang, Zhengwei; Jiang, Kelimu; Zhu, Jianfeng; He, Guixian; Ke, Bilian

    2013-01-01

    To investigate macular pigment optical density (MPOD) and its relationship with refractive status and foveal thickness in Chinese school-aged children. Ninety-four healthy Chinese children, 6 to 12 years old, were recruited to the study. MPOD was measured with a heterochromatic flicker photometer (HFP), and foveal thickness, including both minimum and central foveal thicknesses (MFT and CFT, respectively), were measured by optical coherence tomography (OCT) with fast macular map scan. A noncontact tonometer was used to measure intraocular pressure (IOP) followed by determination of the refraction using an autorefractor after cycloplegia. Information on body mass index (BMI) was obtained. The correlation between MPOD values and foveal thickness, spherical equivalent (SE) refraction, IOP, BMI, sex, and age was statistically analyzed using SAS 8.2 statistical software. The MPOD in examined school-aged children was 0.56 ± 0.25, without any significant difference between boys and girls (p = 0.12). MPOD showed no significant association with age, BMI, IOP, SE, MFT, or CFT. In the myopia group, however, there was an inverse relationship between MPOD and MFT (R =-0.66, p = 0.028) and a positive relationship between MPOD and CFT (R = 0.67, p = 0.025). MPOD was inversely related to MFT and positively related to CFT in Chinese school-age children with low-to-moderate myopia. MPOD showed no significant association with age, BMI, IOP, SE or foveal thickness.

  17. Predictability and stability of laser-assisted subepithelial keratectomy with mitomycin C for the correction of high myopia.

    PubMed

    Iu, Lawrence P L; Fan, Michelle C Y; Chen, Ivan N; Lai, Jimmy S M

    2017-06-01

    The purpose of this study was to evaluate the predictability and stability of laser-assisted subepithelial keratectomy (LASEK) with mitomycin C (MMC) in correction of high myopia (≤-6.0 diopters [D]) as compared to low-to-moderate myopia (>-6.0 D).This is a retrospective, comparative, cohort study which included 43 eyes of 43 consecutive patients who underwent LASEK with MMC in a private hospital in Hong Kong by a single surgeon. Twenty-five eyes had high myopia (mean spherical equivalent [SE] = -8.53 ± 1.82 D) and 18 eyes had low-to-moderate myopia (mean SE = -3.99 ± 1.37 D) before surgery.In terms of refractive predictability, mean SE was significantly better in eyes with preoperative low-to-moderate myopia than high myopia at 6 months (0.04 ± 0.23 vs 0.31 ± 0.52 D, P = .035). In terms of refractive stability, between 1 and 3 months, both groups had mean absolute change of SE of around 0.25 D. Between 3 and 6 months, preoperative low-to-moderate myopia group had significantly less absolute change of SE compared to high myopia group (0.07 vs 0.23 D, P = .003). More eyes with preoperative high myopia changed SE by more than 0.25 D than those with low-to-moderate myopia between 3 and 6 months (32.0% vs 5.6%, P = .057).In conclusion, LASEK with MMC is more unpredictable and unstable in correction of high myopia than low-to-moderate myopia. The refractive outcome of most low-to-moderate myopia correction stabilizes at 3 months. Stability is not achieved until after 6 months in high myopia correction.

  18. Visual and refractive outcomes following myopic laser-assisted subepithelial keratectomy with a flying-spot excimer laser.

    PubMed

    McAlinden, Colm; Skiadaresi, Eirini; Moore, Jonathan E

    2011-05-01

    To investigate the visual and refractive outcomes following laser-assisted subepithelial keratectomy (LASEK) surgery with a flying-spot excimer laser. Private practice, Ireland. Case series. In this prospective study, the mean manifest spherical equivalent (SE), sphere, and cylinder were measured preoperatively. All eyes had LASEK surgery with an aberration-free algorithm with the Schwind Amaris excimer laser. Outcomes measured at 1 month, 6 months, and 1 year were uncorrected distance visual acuity (UDVA), manifest refraction, corrected distance visual acuity, contrast sensitivity, aberrometry, and complications. Accuracy, efficacy, and safety were evaluated at 1 year. Preoperatively, the mean SE, sphere, and cylinder in the 80 eyes (48 patients) were -3.58 diopters (D) ± 2.00 (SD), -3.23 ± 1.93 D, and -0.85 ± 0.65 D, respectively. One year postoperatively, the mean SE was -0.00 ± 0.22 D; 57 eyes (71%) were within -0.13 to +0.13 D of the SE, and 71 eyes (98%) were within ±0.50 D. The mean UDVA was -0.06 ± 0.07 logMAR, with an efficacy index of 1.04. The postoperative SE was stable between 1 month, 3 months, and 1 year. One eye (1%) had a change in SE by more than 0.50 D at 6 months and 1 year. There were no statistically significant differences in any aberrations at 1 year. The contrast sensitivity improved from 1.66 ± 0.17 log units preoperatively to 1.72 ± 0.15 log units at 1 month postoperatively (P=.0003), which was unchanged at 6 months and 1 year. This study demonstrated the effectiveness of LASEK for the treatment of myopia with this flying-spot excimer laser. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Myopia and depressive symptoms among older Chinese adults.

    PubMed

    Wu, Yin; Ma, Qinghua; Sun, Hong-Peng; Xu, Yong; Niu, Mei-E; Pan, Chen-Wei

    2017-01-01

    Few population-based data support the hypothesis that refractive errors are associated with depressive symptoms. We aim to assess the impact of myopia on the risk of having depressive symptoms in a community-based cohort of elderly Chinese. A community-based cross-sectional study of 4611 Chinese adults aged 60 years or older was conducted. Depressive symptoms were measured using the 9-item Patient Health Questionnaire (PHQ-9) depression scale in 4597 adults. Refraction was determined by auto-refraction followed by subjective refraction. Myopia was defined as spherical equivalent (SE) < -0.50 diopters (D) and high myopia as SE < -6.00 D. After adjusting for age, gender, education, lifestyle-related exposures, presenting visual acuity and age-related cataract, myopic adults were more likely to have any depressive symptoms compared with non-myopic ones (odds ratio = 1.39; 95% confidence interval 1.04, 1.92). There were no significant differences in the risk of having any depressive symptoms between those with and without high myopia. Myopia or high myopia was not associated with having moderate depressive symptoms. The impact of myopia on depressive symptoms was stronger in adults with no formal education compared with those with formal education. Myopia was related with the presence of depressive symptoms among older adults.

  20. Simultaneous topography-guided PRK followed by corneal collagen cross-linking for keratoconus.

    PubMed

    Kymionis, George D; Kontadakis, Georgios A; Kounis, George A; Portaliou, Dimitra M; Karavitaki, Alexandra E; Magarakis, Michael; Yoo, Sonia; Pallikaris, Ioannis G

    2009-09-01

    To present the results after simultaneous photorefractive keratectomy (PRK) followed by corneal collagen cross-linking (CXL) for progressive keratoconus. Twelve patients (14 eyes) with progressive keratoconus were prospectively treated with customized topography-guided PRK with the Pulzar Z1 (wavelength 213 nm, CustomVis) immediately followed by corneal collagen CXL with the use of riboflavin and ultraviolet A irradiation. Mean follow-up was 10.69+/-5.95 months (range: 3 to 16 months). Mean preoperative spherical equivalent refraction (SE) was -3.03+/-3.23 diopters (D) and defocus was 4.67+/-3.29 D; at last follow-up SE and defocus were statistically significantly reduced to -1.29+/-2.05 D and 3.04+/-2.53 D, respectively (P<.01). Preoperative mean (logMAR) uncorrected visual acuity was 0.99+/-0.81 and best spectacle-corrected visual acuity was 0.21+/-0.19, which improved postoperatively to 0.16+/-0.15 and 0.11+/-0.15, respectively. The mean steepest keratometry was reduced from 48.20+/-3.40 D preoperatively to 45.13+/-1.80 D at last follow-up. Simultaneous PRK followed by CXL seems to be a promising treatment capable of offering functional vision in patients with keratoconus. Copyright 2009, SLACK Incorporated.

  1. Toric phakic implantable collamer lens for correction of astigmatism: 1-year outcomes

    PubMed Central

    Mertens, Erik L

    2011-01-01

    Purpose: The purpose of this study was to assess predictability, efficacy, safety and stability in patients who received a toric implantable collamer lens to correct moderate to high myopic astigmatism. Methods: Forty-three eyes of 23 patients underwent implantation of a toric implantable collamer lens (STAAR Surgical Inc) for astigmatism correction. Mean spherical refraction was −4. 98 ± 3.49 diopters (D) (range: 0 to −13 D), and mean cylinder was −2.62 ± 0.97 D (range: −1.00 to −5.00 D). Main outcomes measures evaluated during a 12-month follow-up included uncorrected visual acuity (UCVA), refraction, best-corrected visual acuity (BCVA), vault, and adverse events. Results: At 12 months the mean Snellen decimal UCVA was 0.87 ± 0.27 and mean BCVA was 0.94 ± 0.21, with an efficacy index of 1.05. More than 60% of the eyes gained ≥1 line of BCVA (17 eyes, safety index of 1.14). The treatment was highly predictable for spherical equivalent (r2 = 0.99) and astigmatic components: J0 (r2 = 0.99) and J45 (r2 = 0.90). The mean spherical equivalent dropped from −7.29 ± 3.4 D to −0.17 ± 0.40 D at 12 months. Of the attempted spherical equivalent, 76.7% of the eyes were within ±0.50 D and 97.7% eyes were within ±1.00 D, respectively. For J0 and J45, 97.7% and 83.7% were within ±0.50 D, respectively. Conclusion: The results of the present study support the safety, efficacy, and predictability of toric implantable collamer lens implantation to treat moderate to high myopic astigmatism. PMID:21468348

  2. Develop real-time dosimetry concepts and instrumentation for long term missions

    NASA Technical Reports Server (NTRS)

    Braby, L. A.

    1982-01-01

    The development of a rugged portable instrument to evaluate dose and dose equivalent is described. A tissue-equivalent proportional counter simulating a 2 micrometer spherical tissue volume was operated satisfactorily for over a year. The basic elements of the electronic system were designed and tested. And finally, the most suitable mathematical technique for evaluating dose equivalent with a portable instrument was selected. Design and fabrication of a portable prototype, based on the previously tested circuits, is underway.

  3. How representative is the 'Representative Value' of refraction provided by the Shin-Nippon NVision-K 5001 autorefractor?

    PubMed

    Tang, Wing Chun; Tang, Ying Yung; Lam, Carly S Y

    2014-01-01

    The aim of the study was to evaluate the level of agreement between the 'Representative Value' (RV) of refraction obtained from the Shin-Nippon NVision-K 5001 instrument with values calculated from individual measurement readings using standard algebraic methods. Cycloplegic autorefraction readings for 101 myopic children aged 8-13 years (10.9 ± 1.42 years) were obtained using the Shin-Nippon NVision-K 5001. Ten autorefractor measurements were taken for each eye. The spherical equivalent (SE), sphere (Sph) and cylindrical component (Cyl) power of each eye were calculated, firstly, by averaging the 10 repeated measurements (Mean SE, Mean Sph and Mean Cyl), and secondly, by the vector representation method (Vector SE, Vector Sph and Vector Cyl). These calculated values were then compared with those of RV (RV SE, RV Sph and RV Cyl) provided by the proprietary software of the NVision-K 5001 using one-way analysis of variance (anova). The agreement between the methods was also assessed. The SE of the subjects ranged from -5.37 to -0.62 D (mean ± SD, = -2.89 ± 1.01 D). The Mean SE was in exact agreement with the Vector SE. There were no significant differences between the RV readings and those calculated using non-vectorial or vectorial methods for any of the refractive powers (SE, p = 0.99; Sph, p = 0.93; Cyl, p = 0.24). The (mean ± SD) differences were: RV SE vs Mean SE (and also RV SE vs Vector SE) -0.01 ± 0.06 D; RV Sph vs Mean Sph, -0.01 ± 0.05 D; RV Sph vs Vector Sph, -0.04 ± 0.06 D; RV Cyl vs Mean Cyl, 0.01 ± 0.07 D; RV Cyl vs Vector Cyl, 0.06 ± 0.09 D. Ninety-eight percent of RV reading differed from their non-vectorial or vectorial counterparts by less than 0.25 D. The RV values showed good agreement to the results calculated using conventional methods. Although the formula used to calculate RV by the NVision-K 5001 autorefractor is proprietary, our results provide validation for the use of RV measurements in clinical practice and vision science research. © 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  4. Spherical subjective refraction with a novel 3D virtual reality based system.

    PubMed

    Pujol, Jaume; Ondategui-Parra, Juan Carlos; Badiella, Llorenç; Otero, Carles; Vilaseca, Meritxell; Aldaba, Mikel

    To conduct a clinical validation of a virtual reality-based experimental system that is able to assess the spherical subjective refraction simplifying the methodology of ocular refraction. For the agreement assessment, spherical refraction measurements were obtained from 104 eyes of 52 subjects using three different methods: subjectively with the experimental prototype (Subj.E) and the classical subjective refraction (Subj.C); and objectively with the WAM-5500 autorefractor (WAM). To evaluate precision (intra- and inter-observer variability) of each refractive tool independently, 26 eyes were measured in four occasions. With regard to agreement, the mean difference (±SD) for the spherical equivalent (M) between the new experimental subjective method (Subj.E) and the classical subjective refraction (Subj.C) was -0.034D (±0.454D). The corresponding 95% Limits of Agreement (LoA) were (-0.856D, 0.924D). In relation to precision, intra-observer mean difference for the M component was 0.034±0.195D for the Subj.C, 0.015±0.177D for the WAM and 0.072±0.197D for the Subj.E. Inter-observer variability showed worse precision values, although still clinically valid (below 0.25D) in all instruments. The spherical equivalent obtained with the new experimental system was precise and in good agreement with the classical subjective routine. The algorithm implemented in this new system and its optical configuration has been shown to be a first valid step for spherical error correction in a semiautomated way. Copyright © 2016 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  5. Protonation of epigallocatechin-3-gallate (EGCG) results in massive aggregation and reduced oral bioavailability of EGCG-dispersed selenium nanoparticles.

    PubMed

    Wu, Shanshan; Sun, Kang; Wang, Xin; Wang, Dongxu; Wan, Xiaochun; Zhang, Jinsong

    2013-07-31

    The current results show that epigallocatechin-3-gallate (EGCG), in the form of phenolic anions at pH 8.0, can effectively disperse selenium nanoparticles. However, at gastric juice pH (1.0), the EGCG-dispersed selenium nanoparticles (referred to as E-Se) extensively aggregated, so that nano features largely disappeared. This demonstrates that deprotonated phenolic anions of EGCG play an important role in maintaining E-Se stability and suggests that E-Se would suffer from reduced oral bioavailability. To validate this conjecture, size-equivalent E-Se and bovine serum albumin (BSA)-dispersed selenium nanoparticles (B-Se), whose physicochemical properties were not altered at pH 1.0, were orally administered to selenium-deficient mice. In comparison to B-Se, the bioavailabilities of E-Se as indicated with hepatic and renal glutathione peroxidase activity and hepatic selenium levels were significantly (p < 0.01) reduced by 39, 32, and 31%, respectively. Therefore, the present study reveals that size-equivalent selenium nanoparticles prepared by different dispersers do not necessarily guarantee equivalent oral bioavailability.

  6. Spherical-earth Gravity and Magnetic Anomaly Modeling by Gauss-legendre Quadrature Integration

    NASA Technical Reports Server (NTRS)

    Vonfrese, R. R. B.; Hinze, W. J.; Braile, L. W.; Luca, A. J. (Principal Investigator)

    1981-01-01

    The anomalous potential of gravity and magnetic fields and their spatial derivatives on a spherical Earth for an arbitrary body represented by an equivalent point source distribution of gravity poles or magnetic dipoles were calculated. The distribution of equivalent point sources was determined directly from the coordinate limits of the source volume. Variable integration limits for an arbitrarily shaped body are derived from interpolation of points which approximate the body's surface envelope. The versatility of the method is enhanced by the ability to treat physical property variations within the source volume and to consider variable magnetic fields over the source and observation surface. A number of examples verify and illustrate the capabilities of the technique, including preliminary modeling of potential field signatures for Mississippi embayment crustal structure at satellite elevations.

  7. Astigmatic Changes after Horizontal Rectus Muscle Surgery in Intermittent Exotropia

    PubMed Central

    Hong, Seung Woo

    2012-01-01

    Purpose To evaluate the changes of refractive astigmatism after horizontal rectus muscle surgery in intermittent exotropic children. Methods Sixty-nine exotropic patients were retrospectively reviewed. Of those, 35 patients received unilateral lateral rectus recession (BLR group, 35 eyes) and 34 patients received unilateral lateral rectus recession and medial rectus resection (R&R group, 34 eyes). Non-cycloplegic refractions were measured until 6 months postoperatively. Spherical equivalent (SE), J0 and J45 using power vectors were calculated to determine and compare the changes of refractive astigmatism and axis in both groups. Results SE significantly decreased after surgery for the first week and did not changed thereafter in both groups (p = 0.000 and p = 0.018, respectively). In BLR group, J0 showed significant changes at the first week and 1 month after surgery (p = 0.005 and p = 0.016, respectively), but in R&R group, J0 changed significantly between 1 week and 3 months postoperatively (p = 0.023 and p = 0.016, respectively). J45 did not change significantly as time passed in both groups (all p > 0.05). There was no statistically significant difference in the magnitude of changes in SE, J0 and J45 between the two groups after the 6-month follow-up (p = 0.500, p = 0.244 and p = 0.202, respectively). Conclusions Horizontal rectus muscle surgery in intermittent exotropic children tends to induce a statistically significant change in astigmatism in the with-the-rule direction and myopic shift in SE. This astigmatism change seems to occur within the first 3 months after surgery. Thus, astigmatism induced by surgery should be checked and corrected at least 3 months after horizontal strabismus surgery. PMID:23204799

  8. Intraoperative aberrometry-based aphakia refraction in patients with cataract: status and options.

    PubMed

    Huelle, Jan O; Druchkiv, Vasyl; Habib, Nabil E; Richard, Gisbert; Katz, Toam; Linke, Stephan J

    2017-02-01

    To explore the application of intraoperative wavefront aberrometry (IWA) for aphakia-based biometry using three existing formulae derived from autorefractive retinoscopy and introducing new improved formulae. In 74 patients undergoing cataract surgery, three repeated measurements of aphakic spherical equivalent (SE) were taken. All measurements were objectively graded for their quality and evaluated with the 'limits of agreement' approach. ORs were calculated and analysis of variance was applied. The intraocular lens (IOL) power that would have given the target refraction was back-calculated from manifest refraction at 3 months postoperatively. Regression analysis was performed to generate two aphakic SE-based formulae for predicting this IOL. The accuracy of the formulae was determined by comparing them to conventional biometry and published aphakia formulae. In 32 eyes, three consecutive aphakic measurements were successful. Objective parameters of IWA map quality significantly impacted measurement variability (p<0.05). The limits of agreement of repeated aphakic SE readings were +0.66 dioptre (D) and -0.69 D. Intraoperative biometry by our formula resulted in 25% and 53% of all cases ±0.50D and ±1.00 D within SE target, respectively. A second formula that took axial length (AL) into account resulted in improved ratios of 41% and 70%, respectively. A reliable application of IWA to calculate IOL power during routine cataract surgery may not be feasible given the high rate of measurement failures and the large variations of the readings. To enable reliable IOL calculation from IWA, measurement precision must be improved and aphakic IOL formulae need to be fine-tuned. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  9. Prevalence and risk factors for refractive errors in the South Indian adult population: The Andhra Pradesh Eye disease study.

    PubMed

    Krishnaiah, Sannapaneni; Srinivas, Marmamula; Khanna, Rohit C; Rao, Gullapalli N

    2009-01-01

    To report the prevalence, risk factors and associated population attributable risk percentage (PAR) for refractive errors in the South Indian adult population. A population-based cross-sectional epidemiologic study was conducted in the Indian state of Andhra Pradesh. A multistage cluster, systematic, stratified random sampling method was used to obtain participants (n = 10293) for this study. The age-gender-area-adjusted prevalence rates in those >/=40 years of age were determined for myopia (spherical equivalent [SE] < -0.5 D) 34.6% (95% confidence interval [CI]: 33.1-36.1), high-myopia (SE < -5.0 D) 4.5% (95% CI: 3.8-5.2), hyperopia (SE > +0.5 D) 18.4% (95% CI: 17.1-19.7), astigmatism (cylinder < -0.5 D) 37.6% (95% CI: 36-39.2), and anisometropia (SE difference between right and left eyes >0.5 D) 13.0% (95% CI: 11.9-14.1). The prevalence of myopia, astigmatism, high-myopia, and anisometropia significantly increased with increasing age (all p < 0.0001). There was no gender difference in prevalence rates in any type of refractive error, though women had a significantly higher rate of hyperopia than men (p < 0.0001). Hyperopia was significantly higher among those with a higher educational level (odds ratio [OR] 2.49; 95% CI: 1.51-3.95) and significantly higher among the hypertensive group (OR 1.24; 95% CI: 1.03-1.49). The severity of lens nuclear opacity was positively associated with myopia and negatively associated with hyperopia. The prevalence of myopia in this adult Indian population is much higher than in similarly aged white populations. These results confirm the previously reported association between myopia, hyperopia, and nuclear opacity.

  10. Ametropias in school-age children in Fada N'Gourma (Burkina Faso, Africa).

    PubMed

    Jiménez, Raimundo; Soler, Margarita; Anera, Rosario G; Castro, José J; Pérez, M Angustias; Salas, Carlos

    2012-01-01

    To assess epidemiological aspects of refractive errors in school-age children in Burkina Faso (west-central Africa). A total of 315 school children (ranging from 6 to 16 years of age and belonging to different ethnic groups) taken at random from two urban schools in eastern Burkina Faso were examined to assess their refractive error, which was determined by non-cycloplegic retinoscopy with optical fogging. The standard Refractive Error Study in Children (RESC) definitions of refractive errors were used: myopia ≤-0.5 D spherical equivalent (SE) in at least one eye, hyperopia ≥2 D SE in at least one eye, astigmatism ≤-0.75 D cylinder in at least one eye, and anisometropia ≥1 D SE difference between the two eyes. Unilateral myopia and bilateral myopia were found in 2.5 and 1%, respectively; unilateral hyperopia in 17.1%, bilateral hyperopia in 8.6%; astigmatism in at least one eye in 11.7%. The highest prevalence value (18.4%) of astigmatism (≤-0.75 D) in at least one eye was found in the Gourmantché ethnic group. The low prevalence of large refractive errors makes visual acuity in these children very good (visual acuity logarithm of the minimum angle of resolution -0.073 ± 0.123 SD). There was a low prevalence of myopia in these African school children. Clinically significant high hyperopia (≥+2 D SE) was also uncommon. There were no significant differences between the distributions of refractive errors according to gender or ethnicity. With respect to age groups, the prevalences of hyperopia and astigmatism were significantly higher in the younger age groups.

  11. Prevalence of amblyopia and refractive errors in an unscreened population of children.

    PubMed

    Polling, Jan-Roelof; Loudon, Sjoukje E; Klaver, Caroline C W

    2012-11-01

    To describe the frequency of refractive errors and amblyopia in unscreened children aged 2 months to 12 years from a rural town in Poland. Five hundred ninety-one children were identified by medical records and examined in a standardized manner.Visual acuity was measured using LogMAR charts; refractive error was determined using retinoscopy or autorefraction after cycloplegia. Myopia was defined as spherical equivalent (SE) ≤ -0.50 D, emmetropia as SE between -0.5 D and+0.5 D, mild hyperopia as SE between +0.5 D and +2.0 D, and high hyperopia as SE Q+2.0 D. Amblyopia was classified as best-corrected visual acuity ≥0.3 (≤ 20/40) LogMAR, in combination with a 2 LogMAR line difference between the two eyes and the presence of an amblyogenic factor. Refractive errors ranged from 84.2% in children aged up to 2 years to 75.5% in those aged 10 to 12 years.Refractive error showed a myopic shift with age; myopia prevalence increased from 2.2% in those aged 6 to 7 years to 6.3% in those aged 10 to 12 years. Of the examined children, 77 (16.3%) had refractive errors, with visual loss; of these,60 (78%) did not use corrections. The prevalence of amblyopia was 3.1%, and refractive error attributed to the amblyopiain 9 of 13 (69%) children. Refractive errors are common in Caucasian children and often remain undiagnosed. The prevalence of amblyopia was three times higher in this unscreened population compared with screened populations. Greater awarenessof these common treatable visual conditions in children is warranted.

  12. Prevalence of refractive errors in a rural South Indian population.

    PubMed

    Raju, Prema; Ramesh, S Ve; Arvind, Hemamalini; George, Ronnie; Baskaran, Mani; Paul, Pradeep G; Kumaramanickavel, Govindasamy; McCarty, Catherine; Vijaya, Lingam

    2004-12-01

    To report the prevalence of refractive errors in a rural south Indian population. Four thousand eight hundred subjects (age, >39 years) from rural south India were enumerated for a population-based study. All participants underwent complete ophthalmic evaluation. Subjects who were phakic in the right eye with best corrected visual acuity of 20/40 or better were included for analysis. Association of refractive errors with age, sex, cataract, and diabetes mellitus were analyzed. Of the 3924 responders, 2508 were eligible. The unadjusted prevalence of emmetropia (spherical equivalent [SE], -0.50 to +0.50 diopter sphere [DS]), myopia (SE < -0.50 DS), high myopia (SE < -5.00 DS), and hyperopia (SE > 0.50 DS) were 50.60%, 26.99%, 3.71%, and 18.70% and age and gender adjusted for the rural Tamil Nadu population were 46.77%, 30.97%, 4.32%, and 17.94%, respectively. The prevalence of emmetropia decreased significantly with age (P < 0.0001), and the prevalence of myopia and high myopia increased significantly with age (P < 0.001) and were significantly associated with nuclear sclerosis (P < 0.001). The prevalence of hyperopia increased until 60 years of age and then decreased. Hyperopia was more common among women than men (P < 0.001) and was negatively associated with nuclear sclerosis (P < 0.001) and positively with diabetes mellitus (P = 0.008). Of the participants with astigmatism (cylindrical error greater than 0.50 DC), 9.80% had with-the-rule (WTR) and 77.44% against-the-rule (ATR) astigmatism. The prevalence of WTR and ATR astigmatism significantly decreased (P < 0.001) and increased (P = 0.006) with age, respectively. The pattern of refractive errors in this rural south Indian population is similar to those reported in other tropical regions of the world.

  13. Prevalence and risk factors for refractive errors in Indians: the Singapore Indian Eye Study (SINDI).

    PubMed

    Pan, Chen-Wei; Wong, Tien-Yin; Lavanya, Raghavan; Wu, Ren-Yi; Zheng, Ying-Feng; Lin, Xiao-Yu; Mitchell, Paul; Aung, Tin; Saw, Seang-Mei

    2011-05-16

    To determine the prevalence and risk factors for refractive errors in middle-aged to elderly Singaporeans of Indian ethnicity. A population-based, cross-sectional study of Indians aged over 40 years of age residing in Southwestern Singapore was conducted. An age-stratified (10-year age group) random sampling procedure was performed to select participants. Refraction was determined by autorefraction followed by subjective refraction. Myopia was defined as spherical equivalent (SE) < -0.50 diopters (D), high myopia as SE < -5.00 D, astigmatism as cylinder < -0.50 D, hyperopia as SE > 0.50 D, and anisometropia as SE difference > 1.00 D. Prevalence was adjusted to the 2000 Singapore census. Of the 4497 persons eligible to participate, 3400 (75.6%) were examined. Complete data were available for 2805 adults with right eye refractive error and no prior cataract surgery. The age-adjusted prevalence was 28.0% (95% confidence interval [CI], 25.8-30.2) for myopia and 4.1% (95% CI, 3.3-5.0) for high myopia. There was a U-shaped relationship between myopia and increasing age. The age-adjusted prevalence was 54.9% (95% CI, 52.0-57.9) for astigmatism, 35.9% (95% CI, 33.7-38.3) for hyperopia, and 9.8% (95% CI, 8.6-11.1) for anisometropia. In a multiple logistic regression model, adults who were female, younger, taller, spent more time reading and writing per day, or had astigmatism were more likely to be myopic. Adults who were older or had myopia or diabetes mellitus had higher risk of astigmatism. In Singapore, the prevalence of myopia in Indian adults is similar to those in Malays, but lower than those in Chinese. Risk factors for myopia are similar across the three ethnic groups in Singapore.

  14. Time Outdoors and Myopia Progression Over 2 Years in Chinese Children: The Anyang Childhood Eye Study.

    PubMed

    Li, Shi-Ming; Li, He; Li, Si-Yuan; Liu, Luo-Ru; Kang, Meng-Tian; Wang, Yi-Peng; Zhang, Fengju; Zhan, Si-Yan; Gopinath, Bamini; Mitchell, Paul; Wang, Ningli

    2015-07-01

    To investigate whether time outdoors and a range of other activities are associated with change in spherical equivalent (SE) and axial length in Chinese children over a period of 2 years. A total of 1997 children aged 12.7 ± 0.5 (10.9-15.6) years in the Anyang Childhood Eye Study (ACES) were examined annually (baseline and two follow-up visits). Myopia was defined as cycloplegic SE < -0.50 diopters (D). Questionnaires were administered to the students and parents at baseline to gauge time spent outdoors and on other tasks. We ran mixed linear models including age, sex, and years of follow-up. In the full cohort of children there was a suggestive association between time spent outdoors and change in axial length; however, the effect size was very small (high versus low tertile: -0.016 mm/y, P = 0.053). The association was observed in children not myopic at baseline (high versus low tertile, -0.036 mm/y; P = 0.009) but not in those already myopic at baseline (high versus low tertile: -0.005 mm/y; P = 0.595). Time outdoors and change in SE showed similar, but nonsignificant, relationships (P > 0.05), perhaps due to insufficient statistical power. The other activities examined and parental myopia were not associated with changes in SE and axial length (P > 0.11). Within the normal range of variation encountered in these Chinese children, a wide range of activities were largely unrelated to myopia progression at this age. However, there was suggestive evidence that greater time outdoors was associated with slower axial elongation in nonmyopic teenagers, but not in existing myopes.

  15. A Randomized Trial Using Progressive Addition Lenses to Evaluate Theories of Myopia Progression in Children with a High Lag of Accommodation

    PubMed Central

    Sinnott, Loraine T.; Mutti, Donald O.; Zadnik, Karla

    2012-01-01

    Purpose. To compare the effect of wearing, then ceasing to wear, progressive addition lenses (PALs) versus single vision lenses (SVLs) on myopia progression in children with high accommodative lag to evaluate accommodative lag and mechanical tension as theories of myopia progression. Methods. Eighty-five children (age range, 6–11 years) with spherical equivalent (SE) cycloplegic autorefraction between −0.75 D and −4.50 D were randomly assigned to wear SVLs or PALs for 1 year; all children wore SVLs a second year. Children had high accommodative lag and also had near esophoria if their myopia was greater than −2.25 D SE. The primary outcome after each year was the previous year's change in SE. Results. When the children were randomly assigned to SVLs or PALs, the adjusted 1-year changes in SE were −0.52 D (SVL group) and −0.35 D (PAL group; treatment effect = 0.18 D; P = 0.01). When all children wore SVLs the second year, there was no difference in myopia progression between SVL and former PAL wearers (0.06 D; P = 0.50). Accommodative lag was not associated with myopia progression. Conclusions. The statistically significant, but clinically small, PAL effect suggests that treatments aimed at reducing foveal defocus may not be as effective as previously thought in myopic children with high accommodative lag. Finding no evidence of treatment loss after discontinuing PAL wear supports hyperopic defocus-based theories such as accommodative lag; however, not finding an association between accommodative lag and myopia progression is inconsistent with the PAL effect being due to decreased foveal blur during near work. (Clinical Trials.gov number, NCT00335049.) PMID:22205604

  16. Evaluation of iris recognition system for wavefront-guided laser in situ keratomileusis for myopic astigmatism.

    PubMed

    Ghosh, Sudipta; Couper, Terry A; Lamoureux, Ecosse; Jhanji, Vishal; Taylor, Hugh R; Vajpayee, Rasik B

    2008-02-01

    To evaluate the visual and refractive outcomes of wavefront-guided laser in situ keratomileusis (LASIK) using an iris recognition system for the correction of myopic astigmatism. Centre for Eye Research Australia, Melbourne Excimer Laser Research Group, and Royal Victorian Eye and Ear Hospital, East Melbourne, Victoria, Australia. A comparative analysis of wavefront-guided LASIK was performed with an iris recognition system (iris recognition group) and without iris recognition (control group). The main parameters were uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity, amount of residual cylinder, manifest spherical equivalent (SE), and the index of success using the Alpins method of astigmatism analysis 1 and 3 months postoperatively. A P value less than 0.05 was considered statistically significant. Preoperatively, the mean SE was -4.32 diopters (D) +/- 1.59 (SD) in the iris recognition group (100 eyes) and -4.55 +/- 1.87 D in the control group (98 eyes) (P = .84). At 3 months, the mean SE was -0.05 +/- 0.21 D and -0.20 +/- 0.40 D, respectively (P = .001), and an SE within +/-0.50 D of emmetropia was achieved in 92.0% and 85.7% of eyes, respectively (P = .07). At 3 months, the UCVA was 20/20 or better in 90.0% and 76.5% of eyes, respectively. A statistically significant difference in the amount of astigmatic correction was seen between the 2 groups (P = .00 and P = .01 at 1 and 3 months, respectively). The index of success was 98.0% in the iris recognition group and 81.6% in the control group (P = .03). Iris recognition software may achieve better visual and refractive outcomes in wavefront-guided LASIK for myopic astigmatism.

  17. Mechanisms of the Wurtzite to Rocksalt Transformation in CdSe Nanocrystals

    NASA Astrophysics Data System (ADS)

    Grünwald, Michael; Rabani, Eran; Dellago, Christoph

    2006-06-01

    We study the pressure-driven phase transition from the four-coordinate wurtzite to the six-coordinate rocksalt structure in CdSe nanocrystals with molecular dynamics computer simulations. With an ideal gas as the pressure medium, we apply hydrostatic pressure to spherical and faceted nanocrystals ranging in diameter from 25 to 62 Å. In spherical crystals, the main mechanism of the transformation involves the sliding of (100) planes, but depending on the specific surface structure we also observe a second mechanism proceeding through the flattening of (100) planes. In faceted crystals, the transition proceeds via a five-coordinated hexagonal structure, which is stabilized at intermediate pressures due to dominant surface energetics.

  18. Risk factors for loss of epithelial flap integrity in laser-assisted subepithelial keratectomy surgery.

    PubMed

    Galindo, Joanna; Fadlallah, Ali; Robinson, Steve; Chelala, Elias; Melki, Samir A

    2016-04-01

    To evaluate risk factors leading to loss of epithelial flap integrity in laser-assisted subepithelial keratectomy (LASEK). Boston Eye Group, Brookline, Massachusetts, USA. Retrospective case study. This retrospective chart review was performed for LASEK surgeries that occurred between January 2009 and October 2013. Logistic regression was performed to determine whether epithelium preservation was correlated with age, sex, sphere, cylinder, spherical equivalent (SE), keratometry, and central corneal thickness (CCT). The study reviewed 1009 eyes of 509 patients with a mean age of 29.1 years ± 12.2 (SD). The mean preoperative spherical refraction was -4.7 ± 2.5 diopters (D), and the mean preoperative cylinder was -1.1 ± 0.8 D. The mean preoperative decimal corrected distance visual acuity was 1.01 ± 0.07. Single-sheet mobilization of the loosened epithelium flap was found in 72.3% of cases. Fragmented preservation events occurred in 17.6% of cases; the flap was discarded in 10.0% of cases. Epithelium preservation was significantly correlated with age (P = .048) but not with other parameters (P > .05 for sex, sphere, cylinder, SE, keratometry, CCT, and surgeon experience). Epithelial flap dissection was less likely to lead to a single epithelial sheet in patients older than 50 years than in younger patients (56.3% versus 74.9%). The mean postoperative decimal uncorrected distance visual acuity (UDVA) at 3 months was 0.98 ± 0.08. There was no statistical difference in postoperative UDVA between the undiscarded flap group and discarded flap group (P = .128). Successful dissection of single-sheet epithelial flap diminished with age. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Refractive Errors and Amblyopia in the UCLA Preschool Vision Program; First Year Results.

    PubMed

    Hendler, Karen; Mehravaran, Shiva; Lu, Xiang; Brown, Stuart I; Mondino, Bartly J; Coleman, Anne L

    2016-12-01

    To report the outcomes of full ophthalmic examination for preschool children in LA County who failed screening with the Retinomax Autorefractor. Retrospective, cross-sectional study. Between August 2012 and May 2013, the University of California Los Angeles (UCLA) preschool vision program screened 11 260 preschool children aged 3-5 years in Los Angeles County using the Retinomax Autorefractor only. Of those, 1007 children who failed the screening were examined by an ophthalmologist on the UCLA Mobile Eye Clinic. Data from the eye examination were recorded for all children. Amblyopia was defined as unilateral if there was ≥2 line interocular difference in the best-corrected visual acuity (BCVA) and as bilateral if BCVA was <20/50 for children <4 years old and <20/40 for children ≥4 years old. Glasses were prescribed for 740 (74%) of those examined. Uncorrected visual acuity for all examined children was 0.4 ± 0.2 (logMAR mean ± SD), and BCVA was 0.2 ± 0.1. Of the 88% who underwent cycloplegia, 58% had hyperopia (spherical equivalent [SE] ≥+0.50 diopter [D]), mean of +2.50 D, and 21% had myopia (SE ≤-0.50 D), mean of -1.40 D. A total of 69% had astigmatism ≥1.50 D, mean of 1.97 D (range 0-5.75). Spherical and cylindrical anisometropia ≥1.00 D were each found in 26% of those examined. Refractive amblyopia was found in 9% of those examined, or 0.8% of the original population. Of the amblyopic subjects, 77% were unilateral. Screening of preschoolers with the Retinomax led to diagnosis and early treatment of uncorrected refractive errors and amblyopia. By treating children early, amblyopia may be prevented, quality of life improved, and academic achievements enhanced. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Reconstruction of living bilayer human skin equivalent utilizing human fibrin as a scaffold.

    PubMed

    Mazlyzam, A L; Aminuddin, B S; Fuzina, N H; Norhayati, M M; Fauziah, O; Isa, M R; Saim, L; Ruszymah, B H I

    2007-05-01

    Our aim of this study was to develop a new methodology for constructing a bilayer human skin equivalent to create a more clinical compliance skin graft composite for the treatment of various skin defects. We utilized human plasma derived fibrin as the scaffold for the development of a living bilayer human skin equivalent: fibrin-fibroblast and fibrin-keratinocyte (B-FF/FK SE). Skin cells from six consented patients were culture-expanded to passage 1. For B-FF/FK SE formation, human fibroblasts were embedded in human fibrin matrix and subsequently another layer of human keratinocytes in human fibrin matrix was stacked on top. The B-FF/FK SE was then transplanted to athymic mice model for 4 weeks to evaluate its regeneration and clinical performance. The in vivo B-FF/FK SE has similar properties as native human skin by histological analysis and expression of basal Keratin 14 gene in the epidermal layer and Collagen type I gene in the dermal layer. Electron microscopy analysis of in vivo B-FF/FK SE showed well-formed and continuous epidermal-dermal junction. We have successfully developed a technique to engineer living bilayer human skin equivalent using human fibrin matrix. The utilization of culture-expanded human skin cells and fibrin matrix from human blood will allow a fully autologous human skin equivalent construction.

  1. Applicability of the single equivalent point dipole model to represent a spatially distributed bio-electrical source

    NASA Technical Reports Server (NTRS)

    Armoundas, A. A.; Feldman, A. B.; Sherman, D. A.; Cohen, R. J.

    2001-01-01

    Although the single equivalent point dipole model has been used to represent well-localised bio-electrical sources, in realistic situations the source is distributed. Consequently, position estimates of point dipoles determined by inverse algorithms suffer from systematic error due to the non-exact applicability of the inverse model. In realistic situations, this systematic error cannot be avoided, a limitation that is independent of the complexity of the torso model used. This study quantitatively investigates the intrinsic limitations in the assignment of a location to the equivalent dipole due to distributed electrical source. To simulate arrhythmic activity in the heart, a model of a wave of depolarisation spreading from a focal source over the surface of a spherical shell is used. The activity is represented by a sequence of concentric belt sources (obtained by slicing the shell with a sequence of parallel plane pairs), with constant dipole moment per unit length (circumferentially) directed parallel to the propagation direction. The distributed source is represented by N dipoles at equal arc lengths along the belt. The sum of the dipole potentials is calculated at predefined electrode locations. The inverse problem involves finding a single equivalent point dipole that best reproduces the electrode potentials due to the distributed source. The inverse problem is implemented by minimising the chi2 per degree of freedom. It is found that the trajectory traced by the equivalent dipole is sensitive to the location of the spherical shell relative to the fixed electrodes. It is shown that this trajectory does not coincide with the sequence of geometrical centres of the consecutive belt sources. For distributed sources within a bounded spherical medium, displaced from the sphere's centre by 40% of the sphere's radius, it is found that the error in the equivalent dipole location varies from 3 to 20% for sources with size between 5 and 50% of the sphere's radius. Finally, a method is devised to obtain the size of the distributed source during the cardiac cycle.

  2. Study Of Dose Distribution In A Human Body In Space Flight With The Spherical Tissue-Equivalent Phantom

    NASA Astrophysics Data System (ADS)

    Shurshakov, Vyacheslav; Akatov, Yu; Petrov, V.; Kartsev, I.; Polenov, Boris; Petrov, V.; Lyagushin, V.

    In the space experiment MATROSHKA-R, the spherical tissue equivalent phantom (30 kg mass, 35 cm diameter and 10 cm central spherical cave) made in Russia has been installed in the star board crew cabin of the ISS Service Module. Due to the specially chosen phantom shape and size, the chord length distributions of the detector locations are attributed to self-shielding properties of the critical organs in a real human body. If compared with the anthropomorphic phantom Rando used inside and outside the ISS, the spherical phantom has lower mass, smaller size, and requires less crew time for the detector retrieval; its tissue-equivalent properties are closer to the standard human body tissue than the Rando-phantom material. In the first phase of the experiment the dose measurements were realized with only passive detectors (thermoluminescent and solid state track detectors). There were two experimental sessions with the spherical phantom in the crew cabin, (1) from Jan. 29, 2004 to Apr. 30, 2004 and (2) from Aug. 11, 2004 to Oct. 10, 2005. The detectors are placed inside the phantom along the axes of 20 containers and on the phantom outer surface in 32 pockets of the phantom jacket. The results obtained with the passive detectors returned to the ground after each session show the dose difference on the phantom surface as much as a factor of 2, the highest dose being observed close to the outer wall of the crew cabin, and the lowest dose being in the opposite location along the phantom diameter. Maximum dose rate measured in the phantom (0.31 mGy/day) is obviously due to the galactic cosmic ray (GCR) and Earth' radiation belt contribution on the ISS trajectory. Minimum dose rate (0.15 mGy/day) is caused mainly by the strongly penetrating GCR particles and is observed behind more than 5 g/cm2 tissue shielding. Critical organ doses, mean-tissue and effective doses of a crew member in the crew cabin are also estimated with the spherical phantom. The estimated effective dose rate (about 0.49 mSv/day at radiation quality factor of 2.6) is from 12 to 15 per cent lower than the averaged dose on the phantom surface as dependent on the body attitude.

  3. Empirical Relationships Between Optical Properties and Equivalent Diameters of Fractal Soot Aggregates at 550 Nm Wavelength.

    NASA Technical Reports Server (NTRS)

    Pandey, Apoorva; Chakrabarty, Rajan K.; Liu, Li; Mishchenko, Michael I.

    2015-01-01

    Soot aggregates (SAs)-fractal clusters of small, spherical carbonaceous monomers-modulate the incoming visible solar radiation and contribute significantly to climate forcing. Experimentalists and climate modelers typically assume a spherical morphology for SAs when computing their optical properties, causing significant errors. Here, we calculate the optical properties of freshly-generated (fractal dimension Df = 1.8) and aged (Df = 2.6) SAs at 550 nm wavelength using the numericallyexact superposition T-Matrix method. These properties were expressed as functions of equivalent aerosol diameters as measured by contemporary aerosol instruments. This work improves upon previous efforts wherein SA optical properties were computed as a function of monomer number, rendering them unusable in practical applications. Future research will address the sensitivity of variation in refractive index, fractal prefactor, and monomer overlap of SAs on the reported empirical relationships.

  4. Comparison of Manual Refraction Versus Autorefraction in 60 Diabetic Retinopathy Patients.

    PubMed

    Shirzadi, Keyvan; Shahraki, Kourosh; Yahaghi, Emad; Makateb, Ali; Khosravifard, Keivan

    2016-07-27

    The purpose of the study was to evaluate the comparison of manual refraction versus autorefraction in diabetic retinopathy patients. The study was conducted at the Be'sat Army Hospital from 2013-2015. In the present study differences between two common refractometry methods (manual refractometry and Auto refractometry) in diagnosis and follow up of retinopathy in patients affected with diabetes is investigated. Our results showed that there is a significant difference in visual acuity score of patients between manual and auto refractometry. Despite this fact, spherical equivalent scores of two methods of refractometry did not show a significant statistical difference in the patients. Although use of manual refraction is comparable with autorefraction in evaluating spherical equivalent scores in diabetic patients affected with retinopathy, but in the case of visual acuity results from these two methods are not comparable.

  5. On the equivalence of spherical splines with least-squares collocation and Stokes's formula for regional geoid computation

    NASA Astrophysics Data System (ADS)

    Ophaug, Vegard; Gerlach, Christian

    2017-11-01

    This work is an investigation of three methods for regional geoid computation: Stokes's formula, least-squares collocation (LSC), and spherical radial base functions (RBFs) using the spline kernel (SK). It is a first attempt to compare the three methods theoretically and numerically in a unified framework. While Stokes integration and LSC may be regarded as classic methods for regional geoid computation, RBFs may still be regarded as a modern approach. All methods are theoretically equal when applied globally, and we therefore expect them to give comparable results in regional applications. However, it has been shown by de Min (Bull Géod 69:223-232, 1995. doi: 10.1007/BF00806734) that the equivalence of Stokes's formula and LSC does not hold in regional applications without modifying the cross-covariance function. In order to make all methods comparable in regional applications, the corresponding modification has been introduced also in the SK. Ultimately, we present numerical examples comparing Stokes's formula, LSC, and SKs in a closed-loop environment using synthetic noise-free data, to verify their equivalence. All agree on the millimeter level.

  6. Results on Dose Distributions in a Human Body from the Matroshka-R Experiment onboard the ISS Obtained with the Tissue-Equivalent Spherical Phantom

    NASA Astrophysics Data System (ADS)

    Shurshakov, Vyacheslav; Nikolaev, Igor; Kartsev, Ivan; Tolochek, Raisa; Lyagushin, Vladimir

    The tissue-equivalent spherical phantom (32 kg mass, 35 cm diameter and 10 cm central spherical cave) made in Russia has been used on board the ISS in Matroshka-R experiment for more than 10 years. Both passive and active space radiation detectors can be located inside the phantom and on its surface. Due to the specially chosen phantom shape and size, the chord length distributions of the detector locations are attributed to self-shielding properties of the critical organs in a human body. Originally the spherical phantom was installed in the star board crew cabin of the ISS Service Module, then in the Piers-1, MIM-2, and MIM-1 modules of the ISS Russian segment, and finally in JAXA Kibo module. Total duration of the detector exposure is more than 2000 days in 9 sessions of the space experiment. In the first phase of the experiment with the spherical phantom the dose measurements were realized with only passive detectors (thermoluminescent and solid state track detectors). The detectors are placed inside the phantom along the axes of 20 containers and on the phantom outer surface in 32 pockets of the phantom jacket. After each session the passive detectors are returned to the ground. The results obtained show the dose difference on the phantom surface as much as a factor of 2, the highest dose being usually observed close to the outer wall of the compartment, and the lowest dose being in the opposite location along the phantom diameter. However, because of the ISS module shielding properties an inverse dose distribution in a human body can be observed when the dose rate maximum is closer to the geometrical center of the module. Maximum dose rate measured in the phantom is obviously due to the action of two radiation sources, namely, galactic cosmic rays (GCR) and Earth’ radiation belts. Minimum dose rate is produced mainly by the strongly penetrating GCR particles and is mostly observed behind more than 5 g/cm2 tissue shielding. Critical organ doses, mean-tissue and effective doses of a crew member in the ISS compartments are also estimated with the spherical phantom data. The estimated effective dose rate is found to be from 10 % to 15 % lower than the averaged dose on the phantom surface as dependent on the attitude of the critical organs. If compared with the anthropomorphic phantom Rando used inside and outside the ISS earlier, the Matroshka-R space experiment spherical phantom has lower mass, smaller size, and requires less crew time for the detector installation/retrieval; its tissue-equivalent properties are closer to the standard human body tissue than the Rando-phantom material. New sessions with the two tissue-equivalent phantoms are of great interest. Development of modified passive and active detector sets is in progress for the future ISS expeditions. Both the spherical and Rando-type phantoms proved their effectiveness to measure the critical organ doses and effective doses in-flight and if supplied with modernized dosimeters can be recommended for future exploratory manned missions to monitor continuously the crew exposure to space radiation.

  7. Validity of the Aluminum Equivalent Approximation in Space Radiation Shielding

    NASA Technical Reports Server (NTRS)

    Badavi, Francis F.; Adams, Daniel O.; Wilson, John W.

    2009-01-01

    The origin of the aluminum equivalent shield approximation in space radiation analysis can be traced back to its roots in the early years of the NASA space programs (Mercury, Gemini and Apollo) wherein the primary radiobiological concern was the intense sources of ionizing radiation causing short term effects which was thought to jeopardize the safety of the crew and hence the mission. Herein, it is shown that the aluminum equivalent shield approximation, although reasonably well suited for that time period and to the application for which it was developed, is of questionable usefulness to the radiobiological concerns of routine space operations of the 21 st century which will include long stays onboard the International Space Station (ISS) and perhaps the moon. This is especially true for a risk based protection system, as appears imminent for deep space exploration where the long-term effects of Galactic Cosmic Ray (GCR) exposure is of primary concern. The present analysis demonstrates that sufficiently large errors in the interior particle environment of a spacecraft result from the use of the aluminum equivalent approximation, and such approximations should be avoided in future astronaut risk estimates. In this study, the aluminum equivalent approximation is evaluated as a means for estimating the particle environment within a spacecraft structure induced by the GCR radiation field. For comparison, the two extremes of the GCR environment, the 1977 solar minimum and the 2001 solar maximum, are considered. These environments are coupled to the Langley Research Center (LaRC) deterministic ionized particle transport code High charge (Z) and Energy TRaNsport (HZETRN), which propagates the GCR spectra for elements with charges (Z) in the range I <= Z <= 28 (H -- Ni) and secondary neutrons through selected target materials. The coupling of the GCR extremes to HZETRN allows for the examination of the induced environment within the interior' of an idealized spacecraft as approximated by a spherical shell shield, and the effects of the aluminum equivalent approximation for a good polymeric shield material such as genetic polyethylene (PE). The shield thickness is represented by a 25 g/cm spherical shell. Although one could imagine the progression to greater thickness, the current range will be sufficient to evaluate the qualitative usefulness of the aluminum equivalent approximation. Upon establishing the inaccuracies of the aluminum equivalent approximation through numerical simulations of the GCR radiation field attenuation for PE and aluminum equivalent PE spherical shells, we Anther present results for a limited set of commercially available, hydrogen rich, multifunctional polymeric constituents to assess the effect of the aluminum equivalent approximation on their radiation attenuation response as compared to the generic PE.

  8. New Knowledge Derived from Learned Knowledge: Functional-Anatomic Correlates of Stimulus Equivalence

    ERIC Educational Resources Information Center

    Schlund, Michael W.; Hoehn-Saric, Rudolf; Cataldo, Michael F.

    2007-01-01

    Forming new knowledge based on knowledge established through prior learning is a central feature of higher cognition that is captured in research on stimulus equivalence (SE). Numerous SE investigations show that reinforcing behavior under control of distinct sets of arbitrary conditional relations gives rise to stimulus control by new, "derived"…

  9. Zyoptix wavefront-guided versus standard photorefractive keratectomy (PRK) in low and moderate myopia: randomized controlled 6-month study.

    PubMed

    Mastropasqua, L; Toto, L; Zuppardi, E; Nubile, M; Carpineto, P; Di Nicola, M; Ballone, E

    2006-01-01

    To evaluate the refractive and aberrometric outcome of wavefront-guided photorefractive keratectomy (PRK) compared to standard PRK in myopic patients. Fifty-six eyes of 56 patients were included in the study and were randomly divided into two groups. The study group consisted of 28 eyes with a mean spherical equivalent (SE) of -2.25+/-0.76 diopters (D) (range: -1.5 to -3.5 D) treated with wavefront-guided PRK using the Zywave ablation profile and the Bausch & Lomb Technolas 217z excimer laser (Zyoptix system) and the control group included 28 eyes with a SE of -2.35+/-1.01 D (range: -1.5 to -3.5 D) treated with standard PRK (PlanoScan ablation) using the same laser. A Zywave aberrometer was used to analyze and calculate the root-mean-square (RMS) of total high order aberrations (HOA) and Zernike coefficients of third and fourth order before and after (over a 6-month follow-up period) surgery in both groups. Preoperative and postoperative SE, un-corrected visual acuity (UCVA), and best-corrected visual acuity (BCVA) were evaluated in all cases. There was a high correlation between achieved and intended correction. The differences between the two treatment groups were not statistically significant for UCVA, BCVA, or SE cycloplegic refraction . Postoperatively the RMS value of high order aberrations was raised in both groups. At 6-month control, on average it increased by a factor of 1.17 in the Zyoptix PRK group and 1.54 in the PlanoScan PRK group (p=0.22). In the Zyoptix group there was a decrease of coma aberration, while in the PlanoScan group this third order aberration increased. The difference between postoperative and preoperative values between the two groups was statistically significant for coma aberration (p=0.013). No statistically significant difference was observed for spherical-like aberration between the two groups. In the study group eyes with a low amount of preoperative aberrations (HOA RMS lower than the median value; <0.28 microm) showed an increase of HOA RMS while eyes with RMS higher than 0.28 microm showed a decrease (p<0.05). Zyoptix wavefront-guided PRK is as safe and efficacious for the correction of myopia and myopic astigmatism as PlanoScan PRK. Moreover this technique induces a smaller increase of third order coma aberration compared to standard PRK. The use of Zyoptix wavefront-guided PRK is particularly indicated in eyes with higher preoperative RMS values.

  10. Refractive and ocular biometric profile of children with a history of laser treatment for retinopathy of prematurity.

    PubMed

    Kaur, Savleen; Sukhija, Jaspreet; Katoch, Deeksha; Sharma, Mansi; Samanta, Ramanuj; Dogra, Mangat R

    2017-09-01

    Indian children belong to a diverse socioeconomic strata with retinopathy of prematurity (ROP) developing in mature, higher birth weight babies as well. The purpose of our study is to analyze the long-term status of refractive errors and its relationship with ocular biometry in children with ROP who were laser treated at a tertiary center in North India. Cross sectional study. Children (<16 years) enrolled from January 2014 to December 2014 with a history of laser treatment for ROP and examined for refractive and biometric status. Thirty-six children presenting to us at the mean age of 7.37 ± 3.07 years (6-15 years) were included. Mean spherical equivalent (SE) was -4.05 D ± 5.10. 75% were myopic, with high astigmatism in 31%. Higher lens thickness (P = 0.03) and higher SE (P = 0.002) at 1 year postnatal age were predictors of larger SE. 79.4% achieved a favorable functional outcome (visual acuity ≥20/40). 5.88% achieved unsatisfactory outcome (<20/200) despite having a favorable structural outcome. There are a substantial number of children who develop myopia and high astigmatism while undergoing laser treatment for ROP. We found myopia in our cohort to be lenticular and greater axial length contributing to the development of high myopia. An initial large refractive error predicts the future development of myopia in these children. Nearly 6% of patients with good structural outcome have unexplained subnormal vision. Our threshold for prescribing glasses in these children should be low.

  11. Macular Pigment Optical Density and Ocular Pulse Amplitude in Subjects with Different Axial Lengths and Refractive Errors.

    PubMed

    Czepita, Maciej; Karczewicz, Danuta; Safranow, Krzysztof; Czepita, Damian

    2015-06-13

    The purpose of our study was to: (1) investigate the macular pigment optical density (MPOD) and ocular pulse amplitude (OPA) in subjects with different axial lengths (AL) and refractive errors (RE); (2) determine if there is a correlation between MPOD and OPA; and (3) evaluate whether MPOD and OPA depend on intraocular pressure (IOP). This study included 140 eyes of 70 subjects - 17 men and 53 women, aged 18 to 29 years (mean: 22.5 years; SD=2.8). Every examined person underwent a thorough eye examination including: visual acuity, anterior segment and fundus examination, keratometry, auto-refractometry, and MPOD, OPA, AL, and IOP measurements. The obtained results were analyzed statistically using Statistica 10 software. P values of <0.05 were considered statistically significant. The following refractive errors were selected: emmetropia (34 eyes), hyperopia (18 eyes), low myopia (60 eyes), medium myopia (19 eyes), and high myopia (9 eyes). It has been established that the OPA increases with the rise in the spherical equivalents (SE) (Rs=+0.38, P<0.001), while the increase in AL correlates with the decrease of OPA (Rs=-0.40, P<0.001). The increase in IOP correlates with the rise in the OPA (Rs=+0.20, P<0.05). There were no significant correlations between IOP and SE or AL. (1) MPOD is not correlated with the OPA in subjects with different AL and RE; (2) OPA decreases with the rise of AL; (3) OPA decreases with the fall of the SE; and (4) OPA increases with the rise in IOP.

  12. Refractive and ocular biometric profile of children with a history of laser treatment for retinopathy of prematurity

    PubMed Central

    Kaur, Savleen; Sukhija, Jaspreet; Katoch, Deeksha; Sharma, Mansi; Samanta, Ramanuj; Dogra, Mangat R

    2017-01-01

    Purpose: Indian children belong to a diverse socioeconomic strata with retinopathy of prematurity (ROP) developing in mature, higher birth weight babies as well. The purpose of our study is to analyze the long-term status of refractive errors and its relationship with ocular biometry in children with ROP who were laser treated at a tertiary center in North India. Methods: Cross sectional study. Children (<16 years) enrolled from January 2014 to December 2014 with a history of laser treatment for ROP and examined for refractive and biometric status. Results: Thirty-six children presenting to us at the mean age of 7.37 ± 3.07 years (6–15 years) were included. Mean spherical equivalent (SE) was −4.05 D ± 5.10. 75% were myopic, with high astigmatism in 31%. Higher lens thickness (P = 0.03) and higher SE (P = 0.002) at 1 year postnatal age were predictors of larger SE. 79.4% achieved a favorable functional outcome (visual acuity ≥20/40). 5.88% achieved unsatisfactory outcome (<20/200) despite having a favorable structural outcome. Conclusion: There are a substantial number of children who develop myopia and high astigmatism while undergoing laser treatment for ROP. We found myopia in our cohort to be lenticular and greater axial length contributing to the development of high myopia. An initial large refractive error predicts the future development of myopia in these children. Nearly 6% of patients with good structural outcome have unexplained subnormal vision. Our threshold for prescribing glasses in these children should be low. PMID:28905827

  13. Do outside temperature and sunlight duration influence the outcome of laser refractive surgery? Results from the Hamburg Weather Study

    PubMed Central

    Neuhaus-Richard, Ines; Frings, Andreas; Görsch, Isabel Caroline; Druchkiv, Vasyl; Katz, Toam; Linke, Stephan Johannes; Richard, Gisbert

    2014-01-01

    Purpose To examine the impact of temperature and sunlight duration on refractive and visual outcome of laser-assisted in situ keratomileusis (LASIK) in myopic eyes. Setting University Medical Center Hamburg-Eppendorf, Germany, and Care Vision Refractive Centers, Germany. Design Retrospective, cross-sectional data analysis. Methods This study comprised 1,052 eyes of 1,052 consecutive myopic patients (419 males, 633 females; mean age at surgery 35.0±9.0 years) with a mean preoperative refractive spherical equivalent (SE) of −3.88±1.85 diopters (D). Two subgroups were defined, comprising patients undergoing surgery during either meteorological winter or summer. Manifest refraction, uncorrected, and corrected distant visual acuity (UDVA and CDVA) were assessed pre- and postoperatively. We applied robust regression analysis with efficiency index (EI), safety index (SI), and postoperative SE (in D) as dependent variables. Results At the 1-month (33.0±5.0 days) follow-up, the mean postoperative SE was −0.18±0.44 D. Bivariate comparisons showed that statistically significant better EI was related to days with lower temperature. We obtained a significant difference for SI which suggested that low temperature had a positive influence on SI. No change by more than one line on LogMAR scale was obtained. Conclusion Although being statistically significant, there was no clinically relevant difference in the outcome of LASIK, which demonstrates its highly standardized quality. Prospective, longitudinal studies are warranted to address meteorotropic reactions through evaluating defined meteorological parameters. PMID:24966665

  14. Calibration of optical particle-size analyzer

    DOEpatents

    Pechin, William H.; Thacker, Louis H.; Turner, Lloyd J.

    1979-01-01

    This invention relates to a system for the calibration of an optical particle-size analyzer of the light-intercepting type for spherical particles, wherein a rotary wheel or disc is provided with radially-extending wires of differing diameters, each wire corresponding to a particular equivalent spherical particle diameter. These wires are passed at an appropriate frequency between the light source and the light detector of the analyzer. The reduction of light as received at the detector is a measure of the size of the wire, and the electronic signal may then be adjusted to provide the desired signal for corresponding spherical particles. This calibrator may be operated at any time without interrupting other processing.

  15. Computational analysis of non-spherical particle transport and deposition in shear flow with application to lung aerosol dynamics--a review.

    PubMed

    Kleinstreuer, Clement; Feng, Yu

    2013-02-01

    All naturally occurring and most man-made solid particles are nonspherical. Examples include air-pollutants in the nano- to micro-meter range as well as blood constituents, drug particles, and industrial fluid-particle streams. Focusing on the modeling and simulation of inhaled aerosols, theories for both spherical and nonspherical particles are reviewed to analyze the contrasting transport and deposition phenomena of spheres and equivalent spheres versus ellipsoids and fibers.

  16. Calculation of Thermally-Induced Displacements in Spherically Domed Ion Engine Grids

    NASA Technical Reports Server (NTRS)

    Soulas, George C.

    2006-01-01

    An analytical method for predicting the thermally-induced normal and tangential displacements of spherically domed ion optics grids under an axisymmetric thermal loading is presented. A fixed edge support that could be thermally expanded is used for this analysis. Equations for the displacements both normal and tangential to the surface of the spherical shell are derived. A simplified equation for the displacement at the center of the spherical dome is also derived. The effects of plate perforation on displacements and stresses are determined by modeling the perforated plate as an equivalent solid plate with modified, or effective, material properties. Analytical model results are compared to the results from a finite element model. For the solid shell, comparisons showed that the analytical model produces results that closely match the finite element model results. The simplified equation for the normal displacement of the spherical dome center is also found to accurately predict this displacement. For the perforated shells, the analytical solution and simplified equation produce accurate results for materials with low thermal expansion coefficients.

  17. Substantial Equivalence Standards in Tobacco Governance: Statutory Clarity and Regulatory Precedent for the FSPTCA.

    PubMed

    Carpenter, Daniel; Connolly, Gregory N; Lempert, Lauren Kass

    2017-08-01

    The Family Smoking Prevention and Tobacco Control Act (FSPTCA) of 2009 creates the first national system of premarket regulation of tobacco products in American history. The FDA must now review and give marketing authorization to all new tobacco products, based on a public health standard, before they can be legally marketed. Yet the law also contains an alternative pathway for market entry-the substantial equivalence (SE) clause-by which novel and altered tobacco products can be marketed by demonstrating their substantial equivalence to existing products. Over 99 percent of tobacco product applications sent to the FDA under the new law have used this mechanism, and loose application of the SE mechanism carries the risk of undoing the FDA's gatekeeping power under the law. We review the statutory and regulatory precedent for SE, examining the FSPTCA itself as well as regulatory precedent from drug and device regulation (from which the term substantial equivalence and much of the associated statutory language was derived). Our review of standards and scientific precedent demonstrates that exacting scrutiny under the public health standard should govern all SE reviews and that clinical data incorporating social scientific evidence should be routinely required for SE claims by tobacco product sponsors. Copyright © 2017 by Duke University Press.

  18. Three-year results of small incision lenticule extraction and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis for correction of high myopia and myopic astigmatism

    PubMed Central

    Xia, Li-Kun; Ma, Jing; Liu, He-Nan; Shi, Ce; Huang, Qing

    2018-01-01

    AIM To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs), contrast sensitivity (CS) and dry eye parameters after small incision lenticule extraction (SMILE) and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for correction of high myopia and myopic astigmatism. METHODS In this prospective, non-randomized comparative study, 78 eyes with spherical equivalent (SE) of -8.11±1.09 diopters (D) received a SMILE surgery, and 65 eyes with SE of -8.05±1.12 D received a wavefront-guided FS-LASIK surgery with the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany) for flap cutting. Visual acuity, manifest refraction, CS, HOAs, ocular surface disease index (OSDI) and tear break-up time (TBUT) were evaluated during a 3-year follow-up. RESULTS The difference of uncorrected distance visual acuity (UDVA) postoperatively was achieved at 1mo and at 3mo, whereas the difference of the mean UDVA between two groups at 3y were not statistically significant (t=-1.59, P=0.13). The postoperative change of SE was 0.89 D in the FS-LASIK group (t=5.76, P=0.00), and 0.14 D in the SMILE group (t=0.54, P=0.59) from 1mo to 3y after surgery. At 3-year postoperatively, both HOAs and spherical aberrations in the SMILE group were obviously less than those in the FS-LASIK group (P=0.00), but the coma root mean square (RMS) was higher in the SMILE group (0.59±0.26) than in the FS-LASIK group (0.29±0.14, P=0.00). The mesopic CS values between two groups were not statistically significant at 3y postoperatively. Compared with the FS-LASIK group, lower OSDI scores and longer TBUT values were found in the SMILE group at 1mo and 3mo postoperatively. With regard to safety, no eye lost any line of CDVA in both groups at 3y after surgery. CONCLUSION Both SMILE and wavefront-guided FS-LASIK procedures provide good visual outcomes. Both procedures are effective and safe, but SMILE surgery achieve more stable long-term refractive outcome and better control of early postoperative dry eye as compared to FS-LASIK. PMID:29600182

  19. Three-year results of small incision lenticule extraction and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis for correction of high myopia and myopic astigmatism.

    PubMed

    Xia, Li-Kun; Ma, Jing; Liu, He-Nan; Shi, Ce; Huang, Qing

    2018-01-01

    To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs), contrast sensitivity (CS) and dry eye parameters after small incision lenticule extraction (SMILE) and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for correction of high myopia and myopic astigmatism. In this prospective, non-randomized comparative study, 78 eyes with spherical equivalent (SE) of -8.11±1.09 diopters (D) received a SMILE surgery, and 65 eyes with SE of -8.05±1.12 D received a wavefront-guided FS-LASIK surgery with the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany) for flap cutting. Visual acuity, manifest refraction, CS, HOAs, ocular surface disease index (OSDI) and tear break-up time (TBUT) were evaluated during a 3-year follow-up. The difference of uncorrected distance visual acuity (UDVA) postoperatively was achieved at 1mo and at 3mo, whereas the difference of the mean UDVA between two groups at 3y were not statistically significant ( t =-1.59, P =0.13). The postoperative change of SE was 0.89 D in the FS-LASIK group ( t =5.76, P =0.00), and 0.14 D in the SMILE group ( t =0.54, P =0.59) from 1mo to 3y after surgery. At 3-year postoperatively, both HOAs and spherical aberrations in the SMILE group were obviously less than those in the FS-LASIK group ( P =0.00), but the coma root mean square (RMS) was higher in the SMILE group (0.59±0.26) than in the FS-LASIK group (0.29±0.14, P =0.00). The mesopic CS values between two groups were not statistically significant at 3y postoperatively. Compared with the FS-LASIK group, lower OSDI scores and longer TBUT values were found in the SMILE group at 1mo and 3mo postoperatively. With regard to safety, no eye lost any line of CDVA in both groups at 3y after surgery. Both SMILE and wavefront-guided FS-LASIK procedures provide good visual outcomes. Both procedures are effective and safe, but SMILE surgery achieve more stable long-term refractive outcome and better control of early postoperative dry eye as compared to FS-LASIK.

  20. Application of the holmium:YAG laser for refractive surgery: an update of clinical progress

    NASA Astrophysics Data System (ADS)

    Thompson, Vance M.; Durrie, Daniel S.; Hunkeler, John D.; Hurt, Art C., III; Mann, P. M.; Seiler, Theo; King, Michael C.; Sacharoff, Alex C.; Muller, David F.

    1993-06-01

    We describe the results of a 30 patient Phase I clinical trial using the Laser Thermokeratoplasty (LTK) treatment for correction of hyperopic astigmatism. We report the results for 29 patients who have reached 2 months post-operative. The average pre-op cylinder was reduced from -3.06 Diopters (D) to -1.21 D. Average spherical equivalent (SE) refractive error was reduced from +2.28 to +1.34 D. Six patients have reached 4 months post-op; the average cylinder of these patients has been reduced from -1.92 to -0.79 D while the average SE has been reduced from +1.29 to +0.31 D. Although patients had varying degrees of astigmatism pre-op, all treatments were performed with identical parameters (intended to correct a small amount of astigmatism) to enable us to determine the effect of the procedure without the influence of other factors such as varying zone diameter or laser fluence. The predictability and stability of the LTK procedure are supported by a recent study of 20 patients treated in Germany by Seiler for low to moderate degrees (2 - 4 D) of hyperopia. After 6 months post-op, 16 of 20 patients are within +/- 1 D of the attempted correction. Longer-term follow-up will be necessary to determine the ultimate refractive stability of the LTK procedure.

  1. Foldable iris-fixated intraocular lens implantation in children.

    PubMed

    Ryan, Andrea; Hartnett, Claire; Lanigan, Bernadette; O'Keefe, Michael

    2012-09-01

      To describe the results of foldable iris-fixated intraocular lens (IOL) implantation in children.   Children with high bilateral or unilateral myopia who were intolerant of spectacle or contact lens correction were implanted with an iris-fixated foldable IOL and prospectively followed. We measured pre- and postoperative visual acuity, refraction, endothelial cell density (ECD) and National Eye Institute Visual Functioning Questionnaire-25.   Eleven eyes of six children were implanted. Indications were high bilateral myopia in children with comorbid neurobehavioural disorders, high anisometropia and high myopic astigmatism. Mean preoperative spherical equivalent (SE) refraction was -14.6 dioptres (D)±4.2 SD. Mean follow-up was 15 months. Postoperative SE refraction was -2.40 D±2.40 SD. Corrected distance visual acuity (CDVA) improved from mean logMAR 0.84±0.4 SD to postoperative 0.67±0.34 SD (p=0.005). CDVA was reduced because of coexistent ocular disorders and amblyopia. Vision-related quality of life (QOL) measures improved significantly. There were no intraoperative or postoperative serious complications.   Foldable iris-fixated IOL insertion can give a significant improvement in vision and in vision-related QOL in a subset of paediatric patients with special refractive needs who are intolerant to conventional treatment. Long-term follow-up is required for monitoring of ECD. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.

  2. Influence of stromal refractive index and hydration on corneal laser refractive surgery.

    PubMed

    de Ortueta, Diego; von Rüden, Dennis; Magnago, Thomas; Arba Mosquera, Samuel

    2014-06-01

    To evaluate the influence of the stromal refractive index and hydration on postoperative outcomes in eyes that had corneal laser refractive surgery using the Amaris laser system. Augenzentrum Recklinghausen, Recklinghausen, Germany. Comparative case series. At the 6-month follow-up, right eyes were retrospectively analyzed. The effect of the stromal refractive index and hydration on refractive outcomes was assessed using univariate linear and multilinear correlations. Sixty eyes were analyzed. Univariate linear analyses showed that the stromal refractive index and hydration were correlated with the thickness of the preoperative exposed stroma and was statistically different for laser in situ keratomileusis and laser-assisted subepithelial keratectomy treatments. Univariate multilinear analyses showed that the spherical equivalent (SE) was correlated with the attempted SE and stromal refractive index (or hydration). Analyses suggest overcorrections for higher stromal refractive index values and for lower hydration values. The stromal refractive index and hydration affected postoperative outcomes in a subtle, yet significant manner. An adjustment toward greater attempted correction in highly hydrated corneas and less intended correction in low hydrated corneas might help optimize refractive outcomes. Mr. Magnago and Dr. Arba-Mosquera are employees of and Dr. Diego de Ortueta is a consultant to Schwind eye-tech-solutions GmbH & Co. KG. Mr. Rüden has no financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. Risk factors for treatment failure and recurrence of anisometropic amblyopia.

    PubMed

    Kirandi, Ece Uzun; Akar, Serpil; Gokyigit, Birsen; Onmez, Funda Ebru Aksoy; Oto, Sibel

    2017-08-01

    The aim of this study was to identify factors associated with failed vision improvement and recurrence following occlusion therapy for anisometropic amblyopia in children aged 7-9 years. We retrospectively reviewed the medical records of 64 children aged 7-9 years who had been diagnosed as having anisometropic amblyopia and were treated with patching. Functional treatment failure was defined as final visual acuity in the amblyopic eye of worse than 20/32. Improvement of fewer than two logMAR lines was considered relative treatment failure. Recurrence was defined as the reduction of at least two logMAR levels of visual acuity after decreased or discontinued patching. Functional and relative success rates were 51.6 and 62.5 %, respectively. The most important factor for functional treatment failure [adjusted odds ratio (OR) (95 % confidence interval, CI) 11.57 (1.4-95.74)] and the only risk factor for recurrence [adjusted OR (95 % CI) 3.04 (1.13-8.12)] were the same: high spherical equivalent (SE) of the amblyopic eye. A large interocular difference in the best-corrected visual acuity was found to be a risk factor for both functional and relative failure. High SE of the amblyopic eye was the most influential risk factor for treatment failure and recurrence in compliant children aged 7-9 years.

  4. Effects of vernal and allergic conjunctivitis on severity of keratoconus

    PubMed Central

    Cingu, Abdullah Kursat; Cinar, Yasin; Turkcu, Fatih Mehmet; Sahin, Alparslan; Ari, Seyhmus; Yuksel, Harun; Sahin, Muhammed; Caca, Ihsan

    2013-01-01

    AIM To demonstrate the effects of two different types of allergic conjunctivitis on severity of keratoconus (KC). METHODS We retrospectively reviewed the medical records of 171 KC patients referred between June 2010 and June 2011. The KC patients were divided into 3 groups as KC (group A), KC with vernal keratoconjunctivitis (VKC) (group B) and KC with allergic conjunctivitis (AC) (group C). Main outcome measures were demographic and ocular clinical features including age at presentation, gender, spherical equivalent (SE), best spectacle corrected visual acuity (BCVA), mean keratometric measurement (Km), central corneal thickness (CCT), and intraocular pressure (IOP). Groups were compared in term of study variables. RESULTS The median age at presentation was significantly lower in group B (P<0.001). According to the median SE (P=0.003), BCVA (P=0.022), Km (P<0.001), CCT (P=0.015) and Amsler–Krumeich classification (P<0.001), KC was more severe in group B. There was no significant difference in terms of IOP and corrected IOP among the groups (P=0.44), however there were 4 patients who had increased corrected IOP developed after topical corticosteroid use in group B. The differences among the groups persisted even after controlling for age and gender. CONCLUSION Our findings demonstrated a more severe KC in VKC patients despite their younger age which suggests evaluation of VKC patients as a separate group in keratoconus disease. PMID:23826535

  5. Effects of vernal and allergic conjunctivitis on severity of keratoconus.

    PubMed

    Cingu, Abdullah Kursat; Cinar, Yasin; Turkcu, Fatih Mehmet; Sahin, Alparslan; Ari, Seyhmus; Yuksel, Harun; Sahin, Muhammed; Caca, Ihsan

    2013-01-01

    To demonstrate the effects of two different types of allergic conjunctivitis on severity of keratoconus (KC). We retrospectively reviewed the medical records of 171 KC patients referred between June 2010 and June 2011. The KC patients were divided into 3 groups as KC (group A), KC with vernal keratoconjunctivitis (VKC) (group B) and KC with allergic conjunctivitis (AC) (group C). Main outcome measures were demographic and ocular clinical features including age at presentation, gender, spherical equivalent (SE), best spectacle corrected visual acuity (BCVA), mean keratometric measurement (Km), central corneal thickness (CCT), and intraocular pressure (IOP). Groups were compared in term of study variables. The median age at presentation was significantly lower in group B (P<0.001). According to the median SE (P=0.003), BCVA (P=0.022), Km (P<0.001), CCT (P=0.015) and Amsler-Krumeich classification (P<0.001), KC was more severe in group B. There was no significant difference in terms of IOP and corrected IOP among the groups (P=0.44), however there were 4 patients who had increased corrected IOP developed after topical corticosteroid use in group B. The differences among the groups persisted even after controlling for age and gender. Our findings demonstrated a more severe KC in VKC patients despite their younger age which suggests evaluation of VKC patients as a separate group in keratoconus disease.

  6. Effect of vernal keratoconjunctivitis on vitreous depth in patients with keratoconus.

    PubMed

    Cingü, Abdullah Kürşat; Kaya, Savaş; Çınar, Yasin; Şahin, Muhammed; Türkçü, Fatih Mehmet; Yüksel, Harun; Murat, Mehmet; Çaça, İhsan

    2015-05-01

    The aim of this study was to comparatively evaluate the vitreous depth (VD) of keratoconic eyes in patients with or without vernal keratoconjunctivitis (VKC). Eighty eyes of 80 consecutive keratoconus (KC) patients and 40 emmetropic control subjects were enrolled. KC patients were divided into two groups according to accompanying VKC (VKC-KC group and KC group). Mean outcome measures were best-corrected visual acuity (BCVA), spherical equivalent (SE), mean keratometry (Km), intraocular pressure (IOP), and axial length (AL) and its components. The eyes with the highest Km were selected for statistical analysis for each participant. There were 50, 30, and 40 patients in the VKC-KC group, KC group, and control group respectively. The KC group and VKC-KC group were similar in BCVA, SE, Km, CCT, ACD, LT, and IOP (p>0.05). The mean ACD was significantly lower in the control group when compared with the KC group and VKC-KC group. The mean AL and VD were significantly higher in VKC-KC group than those of KC group and the control group, whereas similar in KC and control groups (p>0.05). In the current study we showed that VKC-associated KC patients have significantly longer AL and VD when compared with KC patients without VKC. Posterior segment elongation in VKC-KC group may be associated with the type IV collagen destruction due to chronic longstanding inflammation in VKC patients.

  7. Primary and secondary particle contributions to the depth dose distribution in a phantom shielded from solar flare and Van Allen protons

    NASA Technical Reports Server (NTRS)

    Santoro, R. T.; Claiborne, H. C.; Alsmiller, R. G., Jr.

    1972-01-01

    Calculations have been made using the nucleon-meson transport code NMTC to estimate the absorbed dose and dose equivalent distributions in astronauts inside space vehicles bombarded by solar flare and Van Allen protons. A spherical shell shield of specific radius and thickness with a 30-cm-diam. tissue ball at the geometric center was used to simulate the spacecraft-astronaut configuration. The absorbed dose and the dose equivalent from primary protons, secondary protons, heavy nuclei, charged pions, muons, photons, and positrons and electrons are given as a function of depth in the tissue phantom. Results are given for solar flare protons with a characteristic rigidity of 100 MV and for Van Allen protons in a 240-nautical-mile circular orbit at 30 degree inclination angle incident on both 20-g/sq cm-thick aluminum and polyethylene spherical shell shields.

  8. Comparison of Manual Refraction Versus Autorefraction in 60 Diabetic Retinopathy Patients

    PubMed Central

    Shirzadi, Keyvan; Shahraki, Kourosh; Yahaghi, Emad; Makateb, Ali; Khosravifard, Keivan

    2016-01-01

    Aim: The purpose of the study was to evaluate the comparison of manual refraction versus autorefraction in diabetic retinopathy patients. Material and Methods: The study was conducted at the Be’sat Army Hospital from 2013-2015. In the present study differences between two common refractometry methods (manual refractometry and Auto refractometry) in diagnosis and follow up of retinopathy in patients affected with diabetes is investigated. Results: Our results showed that there is a significant difference in visual acuity score of patients between manual and auto refractometry. Despite this fact, spherical equivalent scores of two methods of refractometry did not show a significant statistical difference in the patients. Conclusion: Although use of manual refraction is comparable with autorefraction in evaluating spherical equivalent scores in diabetic patients affected with retinopathy, but in the case of visual acuity results from these two methods are not comparable. PMID:27703289

  9. Spherical-earth gravity and magnetic anomaly modeling by Gauss-Legendre quadrature integration

    NASA Technical Reports Server (NTRS)

    Von Frese, R. R. B.; Hinze, W. J.; Braile, L. W.; Luca, A. J.

    1981-01-01

    Gauss-Legendre quadrature integration is used to calculate the anomalous potential of gravity and magnetic fields and their spatial derivatives on a spherical earth. The procedure involves representation of the anomalous source as a distribution of equivalent point gravity poles or point magnetic dipoles. The distribution of equivalent point sources is determined directly from the volume limits of the anomalous body. The variable limits of integration for an arbitrarily shaped body are obtained from interpolations performed on a set of body points which approximate the body's surface envelope. The versatility of the method is shown by its ability to treat physical property variations within the source volume as well as variable magnetic fields over the source and observation surface. Examples are provided which illustrate the capabilities of the technique, including a preliminary modeling of potential field signatures for the Mississippi embayment crustal structure at 450 km.

  10. Preparation of Cd/Pb Chalcogenide Heterostructured Janus Particles via Controllable Cation Exchange

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Jianbing; Chernomordik, Boris D.; Crisp, Ryan W.

    2015-07-28

    We developed a strategy for producing quasi-spherical nanocrystals of anisotropic heterostructures of Cd/Pb chalcogenides. The nanostructures are fabricated via a controlled cation exchange reaction where the Cd2+ cation is exchanged for the Pb2+ cation. The cation exchange reaction is thermally activated and can be controlled by adjusting the reaction temperature or time. We characterized the particles using TEM, XPS, PL, and absorption spectroscopy. With complete exchange, high quality Pb-chalcogenide quantum dots are produced. In addition to Cd2+, we also find suitable conditions for the exchange of Zn2+ cations for Pb2+ cations. The cation exchange is anisotropic starting at one edgemore » of the nanocrystals and proceeds along the <111> direction producing a sharp interface at a (111) crystallographic plane. Instead of spherical core/shell structures, we produced and studied quasi-spherical CdS/PbS and CdSe/PbSe Janus-type heterostructures. Nontrivial PL behavior was observed from the CdS(e)/PbS(e) heterostructures as the Pb:Cd ratio is increased.« less

  11. Preparation of Cd/Pb Chalcogenide Heterostructured Janus Particles via Controllable Cation Exchange.

    PubMed

    Zhang, Jianbing; Chernomordik, Boris D; Crisp, Ryan W; Kroupa, Daniel M; Luther, Joseph M; Miller, Elisa M; Gao, Jianbo; Beard, Matthew C

    2015-07-28

    We developed a strategy for producing quasi-spherical nanocrystals of anisotropic heterostructures of Cd/Pb chalcogenides. The nanostructures are fabricated via a controlled cation exchange reaction where the Cd(2+) cation is exchanged for the Pb(2+) cation. The cation exchange reaction is thermally activated and can be controlled by adjusting the reaction temperature or time. We characterized the particles using TEM, XPS, PL, and absorption spectroscopy. With complete exchange, high quality Pb-chalcogenide quantum dots are produced. In addition to Cd(2+), we also find suitable conditions for the exchange of Zn(2+) cations for Pb(2+) cations. The cation exchange is anisotropic starting at one edge of the nanocrystals and proceeds along the ⟨111⟩ direction producing a sharp interface at a (111) crystallographic plane. Instead of spherical core/shell structures, we produced and studied quasi-spherical CdS/PbS and CdSe/PbSe Janus-type heterostructures. Nontrivial PL behavior was observed from the CdS(e)/PbS(e) heterostructures as the Pb:Cd ratio is increased.

  12. Spherical galaxies.

    NASA Astrophysics Data System (ADS)

    Telles, J. E.; de Souza, R. E.; Penereiro, J. C.

    1990-11-01

    RESUMEN. Presentamos fotometria fotografica de 8 objetos y espectrosco- pla para 3 galaxias, las cuales son buenos candidatos para galaxias esfericas. Los resultados fotometricos se presentan en la forma de iso- fotas y de perfiles radiales promedlo, de los cuales se derivan para- metros estructurales. Estas observaciones combinadas con parametros di- namicos obtenidos de observaciones espectrosc6picas, son consistentes con el plano fundamental derivado por Djorgovski y Davis (1987). ABSTRACT. We present photographic surface photometry for 8 objects and spectroscopy for 3 galaxies which are good candidates for spherical galaxies. Photometric results are presented in the form of isophotes and mean radial profiles from which we derived structural parameters. These observations combined with dynamical parameters obtained from spectroscopic observations are consistent with the fundamental plane derived by Djorgovski and Davis (1987). Keq wo : CALAXIES-ELLIPTICAL

  13. Early outcomes after small incision lenticule extraction and photorefractive keratectomy for correction of high myopia

    PubMed Central

    Chan, Tommy C. Y.; Yu, Marco C. Y.; Ng, Alex; Wang, Zheng; Cheng, George P. M.; Jhanji, Vishal

    2016-01-01

    We prospectively compared visual and refractive outcomes in patients with high myopia and myopic astigmatism after small-incision lenticule extraction (SMILE) and photorefractive keratetctomy (PRK) with mitomycin C. Sixty-six eyes of 33 patients (mean age, 29.7 ± 5.6 years) were included (SMILE: 34 eyes, PRK 32 eyes). Preoperatively, no significant difference was noted in manifest spherical equivalent (p = 0.326), manifest sphere (p = 0.277), and manifest cylinder (p = 0.625) between both groups. At 1 month, there were significant differences in logMAR uncorrected distance visual acuity, efficacy index and manifest refraction spherical equivalent between SMILE and PRK (p ≤ 0.029). At 6 months, the logMAR corrected distance visual acuity (p = 0.594), logMAR uncorrected visual acuity (p = 0.452), efficacy index (p = 0.215) and safety index was (p = 0.537) was comparable between SMILE and PRK. Significant differences were observed in postoperative manifest spherical equivalent (p = 0.044) and manifest cylinder (p = 0.014) between both groups. At the end of 6 months, 100% of the eyes in SMILE group and 69% of the eyes in PRK group were within ±0.50 D of the attempted cylindrical correction. The postoperative difference vector, magnitude of error and absolute angle of error were significantly smaller after SMILE compared to PRK (p ≤ 0.040) implying a trend towards overcorrection of cylindrical correction following PRK. PMID:27601090

  14. Axial Length/Corneal Radius of Curvature Ratio and Myopia in 3-Year-Old Children

    PubMed Central

    Foo, Valencia Hui Xian; Verkicharla, Pavan Kumar; Ikram, Mohammad Kamran; Chua, Sharon Yu Lin; Cai, Shirong; Tan, Chuen Seng; Chong, Yap-Seng; Kwek, Kenneth; Gluckman, Peter; Wong, Tien-Yin; Ngo, Cheryl; Saw, Seang-Mei; on behalf of the GUSTO study group

    2016-01-01

    Purpose This study investigated the association of axial length (AL) to corneal radius of curvature (CRC) ratio with spherical equivalent (SE) in a 3-year old Asian cohort. Methods Three-hundred forty-nine 3-year old Asian children from The Growing Up in Singapore towards Healthy Outcomes (GUSTO) birth cohort study underwent AL and CRC measurements with a noncontact ocular biometer and cycloplegic refraction using an autorefractor. The ratio of AL to CRC (AL/CRC) was calculated for all the participants, and subsequently AL, CRC, and AL/CRC were analyzed in relationship to SE. Results The SE showed better correlation with AL/CRC (Spearman's correlation coefficient, ρ = −0.53; 95% confidence interval [CI]: −0.66; −0.49; P < 0.001) compared to either AL or CRC alone ([ρ = −0.36; 95% CI: −0.51 to 0.51; P = 0.01] and [ρ = 0.05; 95% CI: −0.04 to 0.17; P = 0.34], respectively). Mean AL/CRC was 2.91 ± 0.06 among myopes and decreased to 2.79 ± 0.06 among hyperopes. Axial length to corneal radius of curvature was strongly correlated with SE in myopes (ρ = −0.78; 95% CI: −3.76; −0.79; P = < 0.001), but not in emmetropes and hyperopes ([ρ = −0.39; 95% CI: −10.73; −0.57; P = 0.01] and [ρ = −0.18; 95% CI: −17.28; 12.42; P = 0.38], respectively). Linear regression adjusted for gender and ethnicity showed a 0.74-diopter shift in SE towards myopia with every 0.1 increase in AL/CRC ratio (P < 0.001, r2 = 0.33). Conclusion The correlation between SE and AL/CRC is stronger than that between AL or CRC alone. This suggests that in a research setting, when cycloplegic refraction is difficult to perform on 3-year-old children, AL/CRC may be the next best reference for refractive error. Translational Relevance In the research setting, AL/CRC may be the next best reference for refractive error over AL alone when cycloplegic refraction is unavailable in 3-year old children. PMID:26929885

  15. Refractive Errors in Koreans: The Korea National Health and Nutrition Examination Survey 2008-2012.

    PubMed

    Rim, Tyler Hyungtaek; Kim, Seung-Hyun; Lim, Key Hwan; Choi, Moonjung; Kim, Hye Young; Baek, Seung-Hee

    2016-06-01

    Our study provides epidemiologic data on the prevalence of refractive errors in all age group ≥5 years in Korea. In 2008 to 2012, a total of 33,355 participants aged ≥5 years underwent ophthalmologic examinations. Using the right eye, myopia was defined as a spherical equivalent (SE) less than -0.5 or -1.0 diopters (D) in subjects aged 19 years and older or as an SE less than -0.75 or -1.25 D in subjects aged 5 to 18 years according to non-cycloplegic refraction. Other refractive errors were defined as follows: high myopia as an SE less than -6.0 D; hyperopia as an SE larger than +0.5 D; and astigmatism as a cylindrical error less than -1.0 D. The prevalence and risk factors of myopia were evaluated. Prevalence rates with a 95% confidence interval were determined for myopia (SE <-0.5 D, 51.9% [51.2 to 52.7]; SE <-1.0 D, 39.6% [38.8 to 40.3]), high myopia (5.0% [4.7 to 5.3]), hyperopia (13.4% [12.9 to 13.9]), and astigmatism (31.2% [30.5 to 32.0]). The prevalence of myopia demonstrated a nonlinear distribution with the highest peak between the ages of 19 and 29 years. The prevalence of hyperopia decreased with age in subjects aged 39 years or younger and then increased with age in subjects aged 40 years or older. The prevalence of astigmatism gradually increased with age. Education was associated with all refractive errors; myopia was more prevalent and hyperopia and astigmatism were less prevalent in the highly educated groups. In young generations, the prevalence of myopia in Korea was much higher compared to the white or black populations in Western countries and is consistent with the high prevalence found in most other Asian countries. The overall prevalence of hyperopia was much lower compared to that of the white Western population. Age and education level were significant predictive factors associated with all kinds of refractive errors.

  16. Refractive Errors in Koreans: The Korea National Health and Nutrition Examination Survey 2008-2012

    PubMed Central

    Rim, Tyler Hyungtaek; Kim, Seung-Hyun; Lim, Key Hwan; Choi, Moonjung

    2016-01-01

    Purpose Our study provides epidemiologic data on the prevalence of refractive errors in all age group ≥5 years in Korea. Methods In 2008 to 2012, a total of 33,355 participants aged ≥5 years underwent ophthalmologic examinations. Using the right eye, myopia was defined as a spherical equivalent (SE) less than -0.5 or -1.0 diopters (D) in subjects aged 19 years and older or as an SE less than -0.75 or -1.25 D in subjects aged 5 to 18 years according to non-cycloplegic refraction. Other refractive errors were defined as follows: high myopia as an SE less than -6.0 D; hyperopia as an SE larger than +0.5 D; and astigmatism as a cylindrical error less than -1.0 D. The prevalence and risk factors of myopia were evaluated. Results Prevalence rates with a 95% confidence interval were determined for myopia (SE <-0.5 D, 51.9% [51.2 to 52.7]; SE <-1.0 D, 39.6% [38.8 to 40.3]), high myopia (5.0% [4.7 to 5.3]), hyperopia (13.4% [12.9 to 13.9]), and astigmatism (31.2% [30.5 to 32.0]). The prevalence of myopia demonstrated a nonlinear distribution with the highest peak between the ages of 19 and 29 years. The prevalence of hyperopia decreased with age in subjects aged 39 years or younger and then increased with age in subjects aged 40 years or older. The prevalence of astigmatism gradually increased with age. Education was associated with all refractive errors; myopia was more prevalent and hyperopia and astigmatism were less prevalent in the highly educated groups. Conclusions In young generations, the prevalence of myopia in Korea was much higher compared to the white or black populations in Western countries and is consistent with the high prevalence found in most other Asian countries. The overall prevalence of hyperopia was much lower compared to that of the white Western population. Age and education level were significant predictive factors associated with all kinds of refractive errors. PMID:27247521

  17. Comparison of sequential vs same-day simultaneous collagen cross-linking and topography-guided PRK for treatment of keratoconus.

    PubMed

    Kanellopoulos, Anastasios John

    2009-09-01

    The safety and efficacy of corneal collagen cross-linking (CXL) and topography-guided photorefractive keratectomy (PRK) using a different sequence and timing were evaluated in consecutive keratoconus cases. This study included a total of 325 eyes with keratoconus. Eyes were divided into two groups. The first group (n=127 eyes) underwent CXL with subsequent topography-guided PRK performed 6 months later (sequential group) and the second group (n=198 eyes) underwent CXL and PRK in a combined procedure on the same day (simultaneous group). Statistical differences were examined for pre- to postoperative changes in uncorrected (UCVA, logMAR) and best-spectacle-corrected visual acuity (BSCVA, logMAR), manifest refraction spherical equivalent (MRSE), keratometry (K), topography, central corneal thickness, endothelial cell count, corneal haze, and ectatic progression. Mean follow-up was 36+/-18 months (range: 24 to 68 months). At last follow-up in the sequential group, the mean UCVA improved from 0.9+/-0.3 logMAR to 0.49+/-0.25 logMAR, and mean BSCVA from 0.41+/-0.25 logMAR to 0.16+/-0.22 logMAR. Mean reduction in spherical equivalent refraction was 2.50+/-1.20 diopters (D), mean haze score was 1.2+/-0.5, and mean reduction in K was 2.75+/-1.30 D. In the simultaneous group, mean UCVA improved from 0.96+/-0.2 logMAR to 0.3+/-0.2 logMAR, and mean BSCVA from 0.39+/-0.3 logMAR to 0.11+/-0.16 logMAR. Mean reduction in spherical equivalent refraction was 3.20+/-1.40 D, mean haze score was 0.5+/-0.3, and mean reduction in K was 3.50+/-1.3 D. Endothelial cell count preoperatively and at last follow-up was unchanged (P<.05) in both groups. Statistically, the simultaneous group did better (P<.05) in all fields evaluated, with improvement in UCVA and BSCVA, a greater mean reduction in spherical equivalent refraction and keratometry, and less corneal haze. Same-day simultaneous topography-guided PRK and CXL appears to be superior to sequential CXL with later PRK in the visual rehabilitation of progressing keratoconus. Copyright 2009, SLACK Incorporated.

  18. Measurement of dose distribution in the spherical phantom onboard the ISS-KIBO module -MATROSHKA-R in KIBO-

    NASA Astrophysics Data System (ADS)

    Kodaira, Satoshi; Kawashima, Hajime; Kurano, Mieko; Uchihori, Yukio; Nikolaev, Igor; Ambrozova, Iva; Kitamura, Hisashi; Kartsev, Ivan; Tolochek, Raisa; Shurshakov, Vyacheslav

    The measurement of dose equivalent and effective dose during manned space missions on the International Space Station (ISS) is important for evaluating the risk to astronaut health and safety when exposed to space radiation. The dosimetric quantities are constantly changing and strongly depend on the level of solar activity and the various spacecraft- and orbit-dependent parameters such as the shielding distribution in the ISS module, location of the spacecraft within its orbit relative to the Earth, the attitude (orientation) and altitude. Consequently, the continuous monitoring of dosimetric quantities is required to record and evaluate the personal radiation dose for crew members during spaceflight. The dose distributions in the phantom body and on its surface give crucial information to estimate the dose equivalent in the human body and effective dose in manned space mission. We have measured the absorbed dose and dose equivalent rates using passive dosimeters installed in the spherical phantom in Japanese Experiment Module (“KIBO”) of the ISS in the framework of Matroshka-R space experiment. The exposure duration was 114 days from May 21 to September 12, 2012. The phantom consists of tissue-equivalent material covered with a poncho jacket with 32 pockets on its surface and 20 container rods inside of the phantom. The phantom diameter is 35 cm and the mass is 32 kg. The passive dosimeters consisted of a combination of luminescent detectors of Al _{2}O _{3};C OSL and CaSO _{4}:Dy TLD and CR-39 plastic nuclear track detectors. As one of preliminary results, the dose distribution on the phantom surface measured with OSL detectors installed in the jacket pockets is found to be ranging from 340 muGy/day to 260 muGy/day. In this talk, we will present the detail dose distributions, and variations of LET spectra and quality factor obtained outside and inside of the spherical phantom installed in the ISS-KIBO.

  19. Tensor spherical harmonics theories on the exact nature of the elastic fields of a spherically anisotropic multi-inhomogeneous inclusion

    NASA Astrophysics Data System (ADS)

    Shodja, H. M.; Khorshidi, A.

    2013-04-01

    Eshelby's theories on the nature of the disturbance strains due to polynomial eigenstrains inside an isotropic ellipsoidal inclusion, and the form of homogenizing eigenstrains corresponding to remote polynomial loadings in the equivalent inclusion method (EIM) are not valid for spherically anisotropic inclusions and inhomogeneities. Materials with spherically anisotropic behavior are frequently encountered in nature, for example, some graphite particles or polyethylene spherulites. Moreover, multi-inclusions/inhomogeneities/inhomogeneous inclusions have abundant engineering and scientific applications and their exact theoretical treatment would be of great value. The present work is devoted to the development of a mathematical framework for the exact treatment of a spherical multi-inhomogeneous inclusion with spherically anisotropic constituents embedded in an unbounded isotropic matrix. The formulations herein are based on tensor spherical harmonics having orthogonality and completeness properties. For polynomial eigenstrain field and remote applied loading, several theorems on the exact closed-form expressions of the elastic fields associated with the matrix and all the phases of the inhomogeneous inclusion are stated and proved. Several classes of impotent eigenstrain fields associated to a generally anisotropic inclusion as well as isotropic and spherically anisotropic multi-inclusions are also introduced. The presented theories are useful for obtaining highly accurate solutions of desired accuracy when the constituent phases of the multi-inhomogeneous inclusion are made of functionally graded materials (FGMs).

  20. Safety and efficacy of overnight orthokeratology in myopic children.

    PubMed

    Mika, Renée; Morgan, Bruce; Cron, Michael; Lotoczky, Josh; Pole, John

    2007-05-01

    This prospective case series was conducted to describe the safety and efficacy of orthokeratology with the Emerald Contact Lens for Overnight Orthokeratology (Oprifocon A; Euclid Systems Corporation, Herndon, Virginia) among young myopes. Twenty subjects (ages 10 to 16) were enrolled in the 6-month pilot study. Subjects were fit empirically with overnight orthokeratology lenses and evaluated at 1 day, 1 week, 1 month, 2 months, 3 months, and 6 months. Sixteen subjects completed the study. The mean baseline spherical equivalent refraction (SER) was -2.06 diopters (D) (+/-0.75). The mean SER at 6 months was -0.16 D (+/-0.38). The mean baseline uncorrected acuity was 0.78 (+/-0.28) logarithmic minimum angle of resolution (logMAR) equivalent (20/100 Snellen). The mean logMAR equivalent at 6 months was -0.03 +/- 0.12 (<20/20 Snellen). On average, 40% of eyes showed some type of corneal staining between the 1-week and 6-month visits. No serious adverse events occurred during the study. In contrast to previously published studies that reported maximum results at 2 weeks, subjects reached maximum reduction in myopia at the 1-week visit and, on average, obtained a 92.2% reduction in spherical equivalent refractive error at 6 months. This pilot study lends to a growing body of evidence that short-term correction of mild to moderate myopia with overnight orthokeratology is safe and efficacious in children and adolescents.

  1. Feasibility of Equivalent Dipole Models for Electroencephalogram-Based Brain Computer Interfaces.

    PubMed

    Schimpf, Paul H

    2017-09-15

    This article examines the localization errors of equivalent dipolar sources inverted from the surface electroencephalogram in order to determine the feasibility of using their location as classification parameters for non-invasive brain computer interfaces. Inverse localization errors are examined for two head models: a model represented by four concentric spheres and a realistic model based on medical imagery. It is shown that the spherical model results in localization ambiguity such that a number of dipolar sources, with different azimuths and varying orientations, provide a near match to the electroencephalogram of the best equivalent source. No such ambiguity exists for the elevation of inverted sources, indicating that for spherical head models, only the elevation of inverted sources (and not the azimuth) can be expected to provide meaningful classification parameters for brain-computer interfaces. In a realistic head model, all three parameters of the inverted source location are found to be reliable, providing a more robust set of parameters. In both cases, the residual error hypersurfaces demonstrate local minima, indicating that a search for the best-matching sources should be global. Source localization error vs. signal-to-noise ratio is also demonstrated for both head models.

  2. INTACS before or after laser in situ keratomileusis: correction of thin corneas with moderately high myopia.

    PubMed

    Ito, Mitsutoshi; Arai, Hiroyuki; Fukumoto, Teruki; Toda, Ikuko; Tsubota, Kazuo

    2004-01-01

    Intrastromal corneal ring segments (INTACS Micro-Thin Prescription Inserts by Addition Technologies, Fremont, Calif) were inserted as a combined surgery with laser in situ keratomileusis (LASIK) in six eyes with thin corneas to correct moderately high myopia. INTACS were implanted before LASIK (INTACS-LASIK) in three eyes and after LASIK (LASIK-INTACS) in three eyes. Mean preoperative manifest spherical equivalent refraction was -7.88 diopters. Mean follow-up was 306 days. No intraoperative complications occurred. The LASIK-INTACS eyes were slightly more overcorrected than the INTACS-LASIK eyes because of the enhanced performance of INTACS in the thinned corneal tissue. Induced astigmatism by INTACS per se was less in the LASIK-INTACS eyes than in the INTACS-LASIK eyes. At last examination, uncorrected visual acuity was better than 20/25 in all eyes. Best spectacle-corrected visual acuity was within 1 line of the preoperative value in all eyes. Both methods resulted in significant improvement in visual acuity and refraction. Based on our limited experience, however, LASIK followed by INTACS is preferred for reasons of safety, convenience, and lower induced cylinder.

  3. Corneal higher-order aberrations and higher-order Strehl ratio after aberration-free ablation profile to treat compound myopic astigmatism.

    PubMed

    Brenner, Luis F

    2015-12-01

    To evaluate the changes in corneal higher-order aberrations (HOAs) and their impact on corneal higher-order Strehl ratio after aberration-free ablation profile. Verter Institute, H. Olhos, São Paulo, Brazil. Prospective interventional study. Eyes that had aberration-free myopic ablation were divided into 3 groups, based on the spherical equivalent (SE). The corneal HOAs and higher-order Strehl ratios were calculated before surgery and 3 months after surgery. The postoperative uncorrected-distance visual acuity, corrected-distance visual acuity, and SE did not present statistical differences among groups (88 eyes, P > .05). For a 6 mm pupil, the corneal HOA showed a mean increase of 0.17 μm (range 0.39 to 0.56 μm) (P < .001) and the corneal higher-order Strehl ratio presented a reduction of 0.03 (from 0.25 to 0.22) (P = .001). The following consistent linear predictive model was obtained: corneal HOA induction = 1.474 - 0.032 × SE - 0.225 × OZ, where OZ is the optical zone (R(2) = 0.49, adjusted R(2) = 0.48, P < .001). The corneal HOAs and the higher-order Strehl ratios deteriorated after moderate and high myopic ablations. The worsening in corneal aberrations and optical quality were related to the magnitude of the intended correction and did not affect high-contrast visual performance. The OZ was the only modifiable parameter capable to restrain the optical quality loss. The author has no financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. Cohort study with 4-year follow-up of myopia and refractive parameters in primary schoolchildren in Baoshan District, Shanghai.

    PubMed

    Ma, Yingyan; Zou, Haidong; Lin, Senlin; Xu, Xun; Zhao, Rong; Lu, Lina; Zhao, Huijuan; Li, Qiangqiang; Wang, Ling; Zhu, Jianfeng; He, Xiangui

    2018-03-25

    Cohort studies could not only reveal associations between change of refractive components and onset/progression of myopia, but also risk factors, which is important for understanding mechanism and providing strategies. Prevalence of myopia is high in Shanghai, being reported to be 52.2% in children aged 10 years old. Cohort study. A total of 1856 students from six randomly selected primary schools in Baoshan District, Shanghai. Children underwent comprehensive ocular measurement, including axial length (AL), corneal curvature radius and cycloplegic auto-refraction. Questionnaires about eye usage time were collected. Grade 1 students were followed for 4 years, and grade 2 and 3 students for 2 years. (i) Change of spherical equivalent (SE) and AL and (ii) risk factors for progression and incidence of myopia. The average 2-year progress of SE was 0.91D, 0.91D and 1.11D for grade 1, 2 and 3, respectively, and the average elongation of AL was 0.70 mm, 0.64 mm and 0.71 mm, respectively. Only parental myopia, but not near work time, near work diopter time, outdoor activity time or attending tutoring classes, was associated with myopia incidence and progression in the present population. Using baseline SE could be a simple and effective indicator for myopia prediction. Incidence and progression of myopia is relatively high in schoolchildren in Shanghai compared with children of Western countries, East Asia and other parts of China. Effective strategies to control myopia prevalence are in urgent need. © 2018 The Authors Clinical & Experimental Ophthalmology published by John Wiley & Sons Australia, Ltd on behalf of Royal Australian and New Zealand College of Ophthalmologists.

  5. Comparison of ReLEx SMILE and PRK in terms of visual and refractive outcomes for the correction of low myopia.

    PubMed

    Ganesh, Sri; Brar, Sheetal; Patel, Utsav

    2018-06-01

    To compare the objective and subjective quality of vision after femtosecond laser-assisted small incision lenticule extraction (SMILE) and photorefractive keratectomy (PRK) for low myopia. One hundred and twenty eyes from 60 patients (34 females, 26 males) undergoing bilateral correction of low myopia (≤-4 D SE) with either ReLEx SMILE or PRK were included. Visual acuity, contrast sensitivity and higher-order aberrations were recorded preoperatively and compared postoperatively. A quality of vision questionnaire was scored and analyzed 3 months postoperatively. At 3 months, the SMILE group had significantly better uncorrected and corrected distant visual acuity (CDVA), compared to PRK group (p = 0.01). Post-op spherical equivalent (SE) was comparable in both groups (SMILE = -0.15 ± 0.19 D, PRK = -0.14 ± 0.23 D, p = 0.72). However, SE predictability was better in SMILE group with 97% eyes within ±0.05 D compared to 93% eyes in the PRK group. Total higher-order aberrations (HOAs) were significantly higher in PRK compared to the SMILE group (p = 0.022). The SMILE group demonstrated slightly better contrast sensitivity, which was significant at spatial frequency of 12 cpd (p = 0.03). Four eyes in the PRK group had loss of CDVA by one line due to mild haze. Both SMILE and PRK were effective procedures for correction of low myopia. However, SMILE offered superior quality of vision and patient satisfaction due to better postoperative comfort and lower induction of aberrations at 3 months.

  6. Refractive errors among children, adolescents and adults attending eye clinics in Mexico.

    PubMed

    Gomez-Salazar, Francisco; Campos-Romero, Abraham; Gomez-Campaña, Humberto; Cruz-Zamudio, Cinthia; Chaidez-Felix, Mariano; Leon-Sicairos, Nidia; Velazquez-Roman, Jorge; Flores-Villaseñor, Hector; Muro-Amador, Secundino; Guadron-Llanos, Alma Marlene; Martinez-Garcia, Javier J; Murillo-Llanes, Joel; Sanchez-Cuen, Jaime; Llausas-Vargas, Alejando; Alapizco-Castro, Gerardo; Irineo-Cabrales, Ana; Graue-Hernandez, Enrique; Ramirez-Luquin, Tito; Canizalez-Roman, Adrian

    2017-01-01

    To assess the proportion of refractive errors in the Mexican population that visited primary care optometry clinics in fourteen states of Mexico. Refractive data from 676 856 patients aged 6 to 90y were collected from optometry clinics in fourteen states of Mexico between 2014 and 2015. The refractive errors were classified by the spherical equivalent (SE), as follows: sphere+½ cylinder. Myopia (SE>-0.50 D), hyperopia (SE>+0.50 D), emmetropia (-0.50≤SE≤+0.50), and astigmatism alone (cylinder≥-0.25 D). A negative cylinder was selected as a notation. The proportion (95% confidence interval) among all of the subjects was hyperopia 21.0% (20.9-21.0), emmetropia 40.7% (40.5-40.8), myopia 24.8% (24.7-24.9) and astigmatism alone 13.5% (13.4-13.5). Myopia was the most common refractive error and frequency seemed to increase among the young population (10 to 29 years old), however, hyperopia increased among the aging population (40 to 79 years old), and astigmatism alone showed a decreasing trend with age (6 to 90y; from 19.7% to 10.8%). There was a relationship between age and all refractive errors (approximately 60%, aged 50 and older). The proportion of any clinically important refractive error was higher in males (61.2%) than in females (58.3%; P <0.0001). From fourteen states that collected information, the proportion of refractive error showed variability in different geographical areas of Mexico. Myopia is the most common refractive error in the population studied. This study provides the first data on refractive error in Mexico. Further programs and studies must be developed to address the refractive errors needs of the Mexican population.

  7. Refractive errors among children, adolescents and adults attending eye clinics in Mexico

    PubMed Central

    Gomez-Salazar, Francisco; Campos-Romero, Abraham; Gomez-Campaña, Humberto; Cruz-Zamudio, Cinthia; Chaidez-Felix, Mariano; Leon-Sicairos, Nidia; Velazquez-Roman, Jorge; Flores-Villaseñor, Hector; Muro-Amador, Secundino; Guadron-Llanos, Alma Marlene; Martinez-Garcia, Javier J.; Murillo-Llanes, Joel; Sanchez-Cuen, Jaime; Llausas-Vargas, Alejando; Alapizco-Castro, Gerardo; Irineo-Cabrales, Ana; Graue-Hernandez, Enrique; Ramirez-Luquin, Tito; Canizalez-Roman, Adrian

    2017-01-01

    AIM To assess the proportion of refractive errors in the Mexican population that visited primary care optometry clinics in fourteen states of Mexico. METHODS Refractive data from 676 856 patients aged 6 to 90y were collected from optometry clinics in fourteen states of Mexico between 2014 and 2015. The refractive errors were classified by the spherical equivalent (SE), as follows: sphere+½ cylinder. Myopia (SE>-0.50 D), hyperopia (SE>+0.50 D), emmetropia (-0.50≤SE≤+0.50), and astigmatism alone (cylinder≥-0.25 D). A negative cylinder was selected as a notation. RESULTS The proportion (95% confidence interval) among all of the subjects was hyperopia 21.0% (20.9-21.0), emmetropia 40.7% (40.5-40.8), myopia 24.8% (24.7-24.9) and astigmatism alone 13.5% (13.4-13.5). Myopia was the most common refractive error and frequency seemed to increase among the young population (10 to 29 years old), however, hyperopia increased among the aging population (40 to 79 years old), and astigmatism alone showed a decreasing trend with age (6 to 90y; from 19.7% to 10.8%). There was a relationship between age and all refractive errors (approximately 60%, aged 50 and older). The proportion of any clinically important refractive error was higher in males (61.2%) than in females (58.3%; P<0.0001). From fourteen states that collected information, the proportion of refractive error showed variability in different geographical areas of Mexico. CONCLUSION Myopia is the most common refractive error in the population studied. This study provides the first data on refractive error in Mexico. Further programs and studies must be developed to address the refractive errors needs of the Mexican population. PMID:28546940

  8. Comparison of refractive errors and factors associated with spectacle use in a rural and urban South Indian population.

    PubMed

    Prema, Raju; George, Ronnie; Sathyamangalam Ve, Ramesh; Hemamalini, Arvind; Baskaran, Mani; Kumaramanickavel, Govindaswamy; Catherine, McCarty; Vijaya, Lingam

    2008-01-01

    To compare the prevalence of refractive errors and factors associated with spectacle use in a rural and urban south Indian population. Four thousand eight hundred subjects (age> 39 years) each from rural and urban Tamil Nadu were enumerated for a population-based study. All participants underwent a complete ophthalmic evaluation including best-corrected visual acuity (BCVA), objective and subjective refraction. Out of 3924 rural responders 63.91% and out of 3850 urban responders 81.64% were phakic in the right eye with BCVA of 20/40 or better and were included in the study. Association of spectacle use and refractive errors with different parameters were analysed using logistic regression. Chi square, t test, Chi square for trend and Pearson's correlation coefficient were used for analysis. Spectacle use was significantly higher and positively associated with literacy and employment in the urban population. The age and gender-adjusted prevalence of emmetropia, myopia of spherical equivalent (SE) < or =-0.50 diopter sphere (DS), high myopia (SE < or =-5.00DS), hyperopia (SE> 0.50DS) and astigmatism < or = 0.50 diopter cylinder (DC) were 46.8%, 31.0%, 4.3%, 17.9% and 60.4% respectively in the rural population and 29.0%, 17.6%, 1.5%, 51.9%, 59.1% respectively in the urban population. The prevalence of emmetropia decreased with age ( p p = 0.001) and were associated with nuclear sclerosis ( p = 0.001) in both populations. Hyperopia was commoner among women than men ( p = 0.001); was positively associated with diabetes mellitus ( p = 0.008) in the rural population and negatively with nuclear sclerosis ( p = 0.001) in both populations. Spectacle use was found to be significantly lower in the rural population. The pattern of refractive errors was significantly different between both populations.

  9. Prevalence and risk factors for refractive errors in the Singapore Malay Eye Survey.

    PubMed

    Saw, Seang-Mei; Chan, Yiong-Huak; Wong, Wan-Ling; Shankar, Anoop; Sandar, Mya; Aung, Tin; Tan, Donald T H; Mitchell, Paul; Wong, Tien Yin

    2008-10-01

    To describe the prevalence and risk factors for myopia and other refractive errors in an urban Malay population in Singapore. Population-based, cross-sectional study. Persons of Malay ethnicity, between 40 and 80 years of age, living in Singapore. Refractive error was determined by subjective refraction and if unavailable by autorefraction. Data were analyzed for 2974 adults without previous cataract surgery and who had right eye refraction data. Risk factor data, such as education levels and near work activity, were obtained from a face-to-face interview. Myopia, defined as spherical equivalent (SE) refraction less than -0.5 diopters (D), astigmatism as cylinder less than -0.5 D, hyperopia as SE greater than 0.5 D, and anisometropia as the difference in SE greater than 1.0 D. The prevalence of myopia in the right eye was 30.7% (9.4% unilateral myopia and 21.3% bilateral myopia), the prevalence of astigmatism in the right eye was 33.3% (95% confidence interval [CI, 33.0-33.5), the prevalence of hyperopia in the right eye was 27.4% (95% CI, 24.7-27.6), and the prevalence of anisometropia was 9.9% (95% CI, 9.7-10.0). There was a U-shaped relationship between increasing age and the prevalence of myopia, which was partially explained by the age-related increase in the prevalence of cataract. In a multiple logistic regression model, female sex, age, higher educational level, and cataract were associated with myopia. Adults with myopia were more likely to have astigmatism (P<0.001) in multivariate analyses. A quarter of older adult Malay people in Singapore had myopia. Compared with previous reports of similarly aged Singapore Chinese adults, the prevalence of myopia, astigmatism, and anisometropia was lower, whereas the prevalence of hyperopia was similar.

  10. Effects of Head-Mounted Display on the Oculomotor System and Refractive Error in Normal Adolescents.

    PubMed

    Ha, Suk-Gyu; Na, Kun-Hoo; Kweon, Il-Joo; Suh, Young-Woo; Kim, Seung-Hyun

    2016-07-01

    To investigate the clinical effects of head-mounted display on the refractive error and oculomotor system in normal adolescents. Sixty volunteers (age: 13 to 18 years) watched a three-dimensional movie and virtual reality application of head-mounted display for 30 minutes. The refractive error (diopters [D]), angle of deviation (prism diopters [PD]) at distance (6 m) and near (33 cm), near point of accommodation, and stereoacuity were measured before, immediately after, and 10 minutes after watching the head-mounted display. The refractive error was presented as spherical equivalent (SE). Refractive error was measured repeatedly after every 10 minutes when a myopic shift greater than 0.15 D was observed after watching the head-mounted display. The mean age of the participants was 14.7 ± 1.3 years and the mean SE before watching head-mounted display was -3.1 ± 2.6 D. One participant in the virtual reality application group was excluded due to motion sickness and nausea. After 30 minutes of watching the head-mounted display, the SE, near point of accommodation, and stereoacuity in both eyes did not change significantly (all P > .05). Immediately after watching the head-mounted display, esophoric shift was observed (0.6 ± 1.5 to 0.2 ± 1.5 PD), although it was not significant (P = .06). Transient myopic shifts of 17.2% to 30% were observed immediately after watching the head-mounted display in both groups, but recovered fully within 40 minutes after watching the head-mounted display. There were no significant clinical effects of watching head-mounted display for 30 minutes on the normal adolescent eye. Transient changes in refractive error and binocular alignment were noted, but were not significant. [J Pediatr Ophthalmol Strabismus. 2016;53(4):238-245.]. Copyright 2016, SLACK Incorporated.

  11. Assessment of multifocal contact lens over-refraction using an infrared, open-field autorefractor: A preliminary study.

    PubMed

    Giner, Anna; Aldaba, Mikel; Arjona, Montserrat; Vilaseca, Meritxell; Pujol, Jaume

    2015-10-01

    To evaluate the usefulness of an infrared open-field autorefractor as a predictor of the refractive error when fitting multifocal contact lenses (MCL). Objective and subjective measurements of the non-cycloplegic distance refractive error were compared in patients wearing MCL. We used the Grand Seiko WAM-5500 autorefractor for the objective measurements. Three commercially available MCL were tested. Twenty-one eyes of sixteen healthy adults were included in the study. Over-refraction was evaluated in terms of spherical equivalent (SE) and astigmatic vectors (J0 and J45). The mean difference±SD of each parameter was calculated. The Kolmogorov-Smirnov test was used to verify the normal distribution. Pearson's correlation, Bland and Altman plot and paired sample t test were used to compare the results obtained with both methods. The mean difference between objective and subjective results of the SE over-refraction was 0.13±0.42D; for astigmatic vectors J0 and J45 were 0.03±0.32D and -0.00±0.17D, respectively. The Kolmogorov-Smirnov test showed a normal distribution for all parameters. The highest Pearson's correlation coefficients were obtained for the SE with values of 0.98 without MCL and 0.97 with MCL. The lowest were obtained for J45 with values of 0.65 without MCL and 0.75 with MCL. Significant correlations were obtained for each parameter. The paired sample t test failed to show significant differences in analyzed parameters except for J0 without MCL. The Grand Seiko WAM-5500 can be used as a screening method of over-refraction in the clinical fitting of MCL. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  12. Selenium Nanoparticles Formed by Modulation of Carrageenan Enhance Osteogenic Differentiation of Mesenchymal Stem Cells.

    PubMed

    Kim, Jin; Lee, Ki-Young; Lee, Chang-Moon

    2016-03-01

    Fabrication of nano-sized selenium (Se) particles may help to expend the applications of Se. In this study, we focused on the preparation and characterization of Se nanoparticles (Se NPs) modulated with carrageenan (CA). Furthermore, their influence on osteoblast cell growth was investigated in vitro. Spherical Se-NPs, of 100-200 nm diameter, were prepared simply by adding κ-, ι-, and λ-CA, which has sulfate groups, hydroxyl groups, and carboxyl groups. CA-modulated Se NPs (CA-Se NPs) were readily suspended in liquid medium with no precipitation over long time periods. In particular, it was found through Alizarin Red S staining that the growth of osteoblast D1 cells treated with λ-CA-Se NPs was improved significantly. These results suggest that Se NPs can be prepared simply, using CA, have good suspension stability in liquid medium, and λ-CA-Se NPs may induce the growth of osteoblast cells.

  13. Preparation of Hollow Fe2O3 Nanorods and Nanospheres by Nanoscale Kirkendall Diffusion, and Their Electrochemical Properties for Use in Lithium-Ion Batteries.

    PubMed

    Cho, Jung Sang; Park, Jin-Sung; Kang, Yun Chan

    2016-12-13

    A novel process for the preparation of aggregate-free metal oxide nanopowders with spherical (0D) and non-spherical (1D) hollow nanostructures was introduced. Carbon nanofibers embedded with iron selenide (FeSe) nanopowders with various nanostructures are prepared via the selenization of electrospun nanofibers. Ostwald ripening occurs during the selenization process, resulting in the formation of a FeSe-C composite nanofiber exhibiting a hierarchical structure. These nanofibers transform into aggregate-free hollow Fe 2 O 3 powders via the complete oxidation of FeSe and combustion of carbon. Indeed, the zero- (0D) and one-dimensional (1D) FeSe nanocrystals transform into the hollow-structured Fe 2 O 3 nanopowders via a nanoscale Kirkendall diffusion process, thus conserving their overall morphology. The discharge capacities for the 1000 th cycle of the hollow-structured Fe 2 O 3 nanopowders obtained from the FeSe-C composite nanofibers prepared at selenization temperatures of 500, 800, and 1000 °C at a current density of 1 A g -1 are 932, 767, and 544 mA h g -1 , respectively; and their capacity retentions from the second cycle are 88, 92, and 78%, respectively. The high structural stabilities of these hollow Fe 2 O 3 nanopowders during repeated lithium insertion/desertion processes result in superior lithium-ion storage performances.

  14. Intertester agreement in refractive error measurements.

    PubMed

    Huang, Jiayan; Maguire, Maureen G; Ciner, Elise; Kulp, Marjean T; Quinn, Graham E; Orel-Bixler, Deborah; Cyert, Lynn A; Moore, Bruce; Ying, Gui-Shuang

    2013-10-01

    To determine the intertester agreement of refractive error measurements between lay and nurse screeners using the Retinomax Autorefractor and the SureSight Vision Screener. Trained lay and nurse screeners measured refractive error in 1452 preschoolers (3 to 5 years old) using the Retinomax and the SureSight in a random order for screeners and instruments. Intertester agreement between lay and nurse screeners was assessed for sphere, cylinder, and spherical equivalent (SE) using the mean difference and the 95% limits of agreement. The mean intertester difference (lay minus nurse) was compared between groups defined based on the child's age, cycloplegic refractive error, and the reading's confidence number using analysis of variance. The limits of agreement were compared between groups using the Brown-Forsythe test. Intereye correlation was accounted for in all analyses. The mean intertester differences (95% limits of agreement) were -0.04 (-1.63, 1.54) diopter (D) sphere, 0.00 (-0.52, 0.51) D cylinder, and -0.04 (1.65, 1.56) D SE for the Retinomax and 0.05 (-1.48, 1.58) D sphere, 0.01 (-0.58, 0.60) D cylinder, and 0.06 (-1.45, 1.57) D SE for the SureSight. For either instrument, the mean intertester differences in sphere and SE did not differ by the child's age, cycloplegic refractive error, or the reading's confidence number. However, for both instruments, the limits of agreement were wider when eyes had significant refractive error or the reading's confidence number was below the manufacturer's recommended value. Among Head Start preschool children, trained lay and nurse screeners agree well in measuring refractive error using the Retinomax or the SureSight. Both instruments had similar intertester agreement in refractive error measurements independent of the child's age. Significant refractive error and a reading with low confidence number were associated with worse intertester agreement.

  15. Z-LASIK and Trans-PRK for correction of high-grade myopia: safety, efficacy, predictability and clinical outcomes.

    PubMed

    Gershoni, Assaf; Mimouni, Michael; Livny, Eitan; Bahar, Irit

    2018-03-12

    The aim of the study was to examine the outcomes of transepithelial photorefractive keratectomy (Trans-PRK) and Femtosecond Laser-assisted in situ keratomileusis (Z-LASIK) for the correction of high myopia. A retrospective cohort study design was used. The study group included 792 eyes with high-grade myopia (- 6.0 diopters or higher) or high-grade myopia with astigmatism that were treated with Z-LASIK or Trans-PRK in 2013 through 2014 in an optical outpatient clinic of a large private medical service. The Trans-PRK group comprised of 674 eyes with a spherical equivalent (SE) of - 7.87 ± 1.46 and the Z-LASIK group comprised of 118 eyes with a SE of - 7.19 ± 0.81 (P < 0.001). The mean postoperative SE in the Trans-PRK group was - 0.06 and - 0.02 in the Z-LASIK group (P = 0.545). Efficacy index values were 0.92 in the Trans-PRK group and 0.95 in the Z-LASIK group (P = 0.083), and corresponding safety index values were 0.95 and 0.97 (P = 0.056). An UCVA of 20/40 or better was achieved in 94.20% of eyes in the Trans-PRK group, and 98.31% in the Z-LASIK group (P = 0.063). The majority of eyes in both the Trans-PRK and Z-LASIK groups were within ± 0.5D of attempted correction: 59.35 and 64.71%, respectively (P = 0.271). Both Trans-PRK and Z-LASIK demonstrated excellent efficacy, safety and predictability profiles, with results comparable and in some cases superior to the current literature. Results of Z-LASIK were slightly better than those of Trans-PRK, though the preoperative SE of the latter was higher.

  16. Prevalence and risk factors for refractive errors in the South Indian adult population: The Andhra Pradesh Eye disease study

    PubMed Central

    Krishnaiah, Sannapaneni; Srinivas, Marmamula; Khanna, Rohit C; Rao, Gullapalli N

    2009-01-01

    Aim: To report the prevalence, risk factors and associated population attributable risk percentage (PAR) for refractive errors in the South Indian adult population. Methods: A population-based cross-sectional epidemiologic study was conducted in the Indian state of Andhra Pradesh. A multistage cluster, systematic, stratified random sampling method was used to obtain participants (n = 10293) for this study. Results: The age-gender-area-adjusted prevalence rates in those ≥40 years of age were determined for myopia (spherical equivalent [SE] < −0.5 D) 34.6% (95% confidence interval [CI]: 33.1–36.1), high-myopia (SE < −5.0 D) 4.5% (95% CI: 3.8–5.2), hyperopia (SE > +0.5 D) 18.4% (95% CI: 17.1–19.7), astigmatism (cylinder < −0.5 D) 37.6% (95% CI: 36–39.2), and anisometropia (SE difference between right and left eyes >0.5 D) 13.0% (95% CI: 11.9–14.1). The prevalence of myopia, astigmatism, high-myopia, and anisometropia significantly increased with increasing age (all p < 0.0001). There was no gender difference in prevalence rates in any type of refractive error, though women had a significantly higher rate of hyperopia than men (p < 0.0001). Hyperopia was significantly higher among those with a higher educational level (odds ratio [OR] 2.49; 95% CI: 1.51–3.95) and significantly higher among the hypertensive group (OR 1.24; 95% CI: 1.03–1.49). The severity of lens nuclear opacity was positively associated with myopia and negatively associated with hyperopia. Conclusions: The prevalence of myopia in this adult Indian population is much higher than in similarly aged white populations. These results confirm the previously reported association between myopia, hyperopia, and nuclear opacity. PMID:19668540

  17. Refractive errors among patients attending the ophthalmology department of a medical college in North-East India

    PubMed Central

    Natung, Tanie; Taye, Trishna; Lyngdoh, Laura Amanda; Dkhar, Begonia; Hajong, Ranendra

    2017-01-01

    Purpose: To determine the magnitude and pattern of refractive errors among patients attending the ophthalmology department of a new medical college in North-East India. Materials and Methods: A prospective study of the new patients (age ≥5 years), who were phakic and whose unaided visual acuities were worse than 20/20 but improved with pinhole, was done. Complete ophthalmic examination and refraction with appropriate cycloplegia for age were done for the 4582 eligible patients. Spherical equivalents (SE) of refractive errors of the right eyes were used for analysis. Results: Of the 4582 eligible patients, 2546 patients had refractive errors (55.56%). The proportion of emmetropia (SE − 0.50–+0.50 diopter sphere [DS]), myopia (SE <−0.50 DS), high myopia (SE >−5.0 DS), and hypermetropia (>+0.50 DS for adults and >+2.0 DS for children) were 53.1%, 27.4%, 2.6%, and 16.9%, respectively. The proportion of hyperopia increased till 59 years and then decreased with age (P = 0.000). The proportion of myopia and high myopia decreased significantly with age after 39 years (P = 0.000 and P = 0.004, respectively). Of the 1510 patients with astigmatism, 17% had with-the-rule (WTR), 23.4% had against-the-rule (ATR), and 19% had oblique astigmatisms. The proportion of WTR and ATR astigmatisms significantly decreased (P = 0.000) and increased (P = 0.000) with age, respectively. Conclusions: This study has provided the magnitude and pattern of refractive errors in the study population. It will serve as the initial step for conducting community-based studies on the prevalence of refractive errors in this part of the country since such data are lacking from this region. Moreover, this study will help the primary care physicians to have an overview of the magnitude and pattern of refractive errors presenting to a health-care center as refractive error is an established and significant public health problem worldwide. PMID:29417005

  18. Refractive errors among patients attending the ophthalmology department of a medical college in North-East India.

    PubMed

    Natung, Tanie; Taye, Trishna; Lyngdoh, Laura Amanda; Dkhar, Begonia; Hajong, Ranendra

    2017-01-01

    To determine the magnitude and pattern of refractive errors among patients attending the ophthalmology department of a new medical college in North-East India. A prospective study of the new patients (age ≥5 years), who were phakic and whose unaided visual acuities were worse than 20/20 but improved with pinhole, was done. Complete ophthalmic examination and refraction with appropriate cycloplegia for age were done for the 4582 eligible patients. Spherical equivalents (SE) of refractive errors of the right eyes were used for analysis. Of the 4582 eligible patients, 2546 patients had refractive errors (55.56%). The proportion of emmetropia (SE - 0.50-+0.50 diopter sphere [DS]), myopia (SE <-0.50 DS), high myopia (SE >-5.0 DS), and hypermetropia (>+0.50 DS for adults and >+2.0 DS for children) were 53.1%, 27.4%, 2.6%, and 16.9%, respectively. The proportion of hyperopia increased till 59 years and then decreased with age ( P = 0.000). The proportion of myopia and high myopia decreased significantly with age after 39 years ( P = 0.000 and P = 0.004, respectively). Of the 1510 patients with astigmatism, 17% had with-the-rule (WTR), 23.4% had against-the-rule (ATR), and 19% had oblique astigmatisms. The proportion of WTR and ATR astigmatisms significantly decreased ( P = 0.000) and increased ( P = 0.000) with age, respectively. This study has provided the magnitude and pattern of refractive errors in the study population. It will serve as the initial step for conducting community-based studies on the prevalence of refractive errors in this part of the country since such data are lacking from this region. Moreover, this study will help the primary care physicians to have an overview of the magnitude and pattern of refractive errors presenting to a health-care center as refractive error is an established and significant public health problem worldwide.

  19. Performance of the Plusoptix A09 Photoscreener in Detecting Amblyopia Risk Factors in Chinese Children Attending an Eye Clinic

    PubMed Central

    Xu, Wen-Wen; Li, Feng-Jiao; Wang, Li-Hua

    2015-01-01

    Purpose To assess the accuracy of the Plusoptix A09 photoscreener in detecting amblyopia risk factors in children and determine referral criteria when using Plusoptix A09 for a large-scale vision screening. Methods Pediatric patients attending our eye clinic underwent a comprehensive ophthalmic examination that included photorefraction, orthoptic examination, anterior segment assessment, fundus examination and cycloplegic retinoscopy. The measurements were collected for statistical analyses. Results One hundred and seventy-eight children (mean age ± SD: 6.2±2.4 years, range: 2.2 to 14.1 years) were included in the study. The mean spherical equivalent (SE) obtained using Plusoptix A09 (PSE) was 0.57 D lower than that obtained from cycloplegic retinoscopy (CRSE) (P = 0.00). However, there was no statistically significant difference of Jackson cross cylinder J0 and J45 between Plusoptix A09 (PJ) and cycloplegic retinoscopy (CRJ) (P = 0.14, P = 0.26). The relationship of SE obtained from Plusoptix A09 and SE obtained from cycloplegic retinoscopy was presented as the equation: CRSE = 0.358 + 0.776 PSE + 0.064 PSE 2 + 0.011 PSE 3. Based on the Receiver Operating Characteristic (ROC) curve, the Plusoptix A09 had an overall sensitivity of 94.9% and specificity of 67.5% for detecting refractive amblyopia risk factors. The sensitivity and specificity of the Plusoptix A09 for detection of strabismus were 40.7% and 98.3%, respectively; detection of amblyopia and/or strabismus was 84.7% and 63.2%, respectively. Conclusions The Plusoptix A09 photoscreener underestimated hyperopia and overestimated myopia according to SE when compared with cycloplegic retinoscopy. The accuracy of the Plusoptix A09 in detecting amblyopia risk factors in children could be improved by the regression equation and optimized criteria for refractive amblyopia risk factors developed in the present study. Moreover, the Plusoptix A09 photoscreener is not suitable for a large-scale strabismus screening when it is applied solely. PMID:26030210

  20. The effect of simultaneous negative and positive defocus on eye growth and development of refractive state in marmosets.

    PubMed

    Benavente-Perez, Alexandra; Nour, Ann; Troilo, David

    2012-09-21

    We evaluated the effect of imposing negative and positive defocus simultaneously on the eye growth and refractive state of the common marmoset, a New World primate that compensates for either negative and positive defocus when they are imposed individually. Ten marmosets were reared with multizone contact lenses of alternating powers (-5 diopters [D]/+5 D), 50:50 ratio for average pupil of 2.80 mm over the right eye (experimental) and plano over the fellow eye (control) from 10 to 12 weeks. The effects on refraction (mean spherical equivalent [MSE]) and vitreous chamber depth (VC) were measured and compared to untreated, and -5 D and +5 D single vision contact lens-reared marmosets. Over the course of the treatment, pupil diameters ranged from 2.26 to 2.76 mm, leading to 1.5 times greater exposure to negative than positive power zones. Despite this, at different intervals during treatment, treated eyes were on average relatively more hyperopic and smaller than controls (experimental-control [exp-con] mean MSE ± SE +1.44 ± 0.45 D, mean VC ± SE -0.05 ± 0.02 mm) and the effects were similar to those in marmosets raised on +5 D single vision contact lenses (exp-con mean MSE ± SE +1.62 ± 0.44 D. mean VC ± SE -0.06 ± 0.03 mm). Six weeks into treatment, the interocular growth rates in multizone animals were already lower than in -5 D-treated animals (multizone -1.0 ± 0.1 μm/day, -5 D +2.1 ± 0.9 μm/day) and did not change significantly throughout treatment. Imposing hyperopic and myopic defocus simultaneously using concentric contact lenses resulted in relatively smaller and less myopic eyes, despite treated eyes being exposed to a greater percentage of negative defocus. Exposing the retina to combined dioptric powers with multifocal lenses that include positive defocus might be an effective treatment to control myopia development or progression.

  1. Pseudo-magnetic fields of strongly-curved graphene nanobubbles

    NASA Astrophysics Data System (ADS)

    Liu, Li-Chi

    2018-04-01

    We use the π-orbital axis vector (POAV) analysis to deal with large curvature effect of graphene in the tight-binding model. To test the validities of pseudo-magnetic fields (PMFs) derived from the tight-binding model and the model with Dirac equation coupled to a curved surface, we propose two types of spatially constant-field topographies for strongly-curved graphene nanobubbles, which correspond to these two models, respectively. It is shown from the latter model that the PMF induced by any spherical graphene nanobubble is always equivalent to the magnetic field caused by one magnetic monopole charge distributed on a complete spherical surface with the same radius. Such a PMF might be attributed to the isometry breaking of a graphene layer attached conformably to a spherical substrate with adhesion.

  2. 29 CFR 1926.1003 - Overhead protection for operators of agricultural and industrial tractors used in construction.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... (2) A solid steel sphere or material of equivalent spherical dimension weighing 100 lb (45.4 kg... derived from, and restates, in part, the portions of Society of Automotive Engineers (“SAE”) standard J167...

  3. 29 CFR 1926.1003 - Overhead protection for operators of agricultural and industrial tractors used in construction.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... (2) A solid steel sphere or material of equivalent spherical dimension weighing 100 lb (45.4 kg... derived from, and restates, in part, the portions of Society of Automotive Engineers (“SAE”) standard J167...

  4. 29 CFR 1926.1003 - Overhead protection for operators of agricultural and industrial tractors used in construction.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... (2) A solid steel sphere or material of equivalent spherical dimension weighing 100 lb (45.4 kg... derived from, and restates, in part, the portions of Society of Automotive Engineers (“SAE”) standard J167...

  5. 29 CFR 1926.1003 - Overhead protection for operators of agricultural and industrial tractors used in construction.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... (2) A solid steel sphere or material of equivalent spherical dimension weighing 100 lb (45.4 kg... derived from, and restates, in part, the portions of Society of Automotive Engineers (“SAE”) standard J167...

  6. 29 CFR 1926.1003 - Overhead protection for operators of agricultural and industrial tractors used in construction.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... (2) A solid steel sphere or material of equivalent spherical dimension weighing 100 lb (45.4 kg... derived from, and restates, in part, the portions of Society of Automotive Engineers (“SAE”) standard J167...

  7. Phakic Intraocular Lens Implantation: Refractive Outcome and Safety in Patients with Anterior Chamber Depth between 2.8 and 3.0 versus ≥3.0 mm.

    PubMed

    Guerra, Marta G; Silva, Andreia M M; Marques, Sara H M; Melo, Sofia H; Póvoa, João A; Lobo, Conceição; Murta, Joaquim Neto

    2017-01-01

    To compare endothelial cell (EC) variation after anterior chamber phakic intraocular lens (AC-pIOL) implantation in highly myopic patients with a preoperative anterior chamber depth (ACD) between 2.8 and 3.0 versus ≥3.0 mm. A total of 280 eyes submitted to primary AC-pIOL implantation were analyzed. Pre- and postoperative values for uncorrected distance visual acuity, corrected distance visual acuity, spherical equivalent, ACD (endothelial surface), and EC count were collected. The eyes were divided into 2 groups: group A - ACD between 2.8 and 3.0 mm; group B - ACD ≥3.0 mm. Mean global EC loss (ECL) and loss for each ACD group, according to pIOL type, were analyzed. Significant improvement of the spherical equivalent (-11.38 ± 4.57 vs. -0.49 ± 0.79; p = 0.000) and a significant decrease in EC density (2,810.95 ± 343.88 vs. 2,584.09 ± 374.88 cells/mm2; p = 0.000) were noted. The mean annual ECL was -2.19 ± 3.97%. Regarding group A (n = 80), a mean annual ECL of -2.06 ± 3.88% was registered, higher for the Acrysof Cachet® subtype, while group B (n = 200) showed -2.25 ± 4.01% ECL, higher for the Verisyse® subtype. There was no significant difference between the groups (p = 0.96). AC-pIOL implantation significantly improves the spherical equivalent in myopic patients. The mean annual ECL after pIOL implantation was higher in the larger ACD group, but this value was not statistically significant. A 2.8-mm ACD value seems to be a safe cutoff for AC-pIOL implantation. © 2017 S. Karger AG, Basel.

  8. The Safety and Predictability of Implanting Autologous Lenticule Obtained by SMILE for Hyperopia.

    PubMed

    Sun, Ling; Yao, Peijun; Li, Meiyan; Shen, Yang; Zhao, Jing; Zhou, Xingtao

    2015-06-01

    To evaluate the safety, effectiveness, stability, and predictability of implanting autologous lenticules obtained from small incision lenticule extraction for the treatment of hyperopia. Five patients (10 eyes) with one myopic eye and one hyperopic eye were enrolled. The myopic eye was treated with small incision lenticule extraction; a lenticule was extracted and subsequently implanted in the hyperopic eye. Follow-up was at 1 day, 1, 3, 6, and 9 months, and 1 year postoperatively. Patients received a complete ophthalmologic examination at each visit, including uncorrected distance visual acuity, corrected distance visual acuity, anterior segment optical coherence tomography, and corneal topography. There were no complications in any eye during follow-up. Compared with preoperative levels, at the last follow-up visit the eyes with lenticule implantation showed mean spherical equivalent reduced by 5.53 diopters (residual spherical equivalent was +1.13 to -2.63 diopters), mean uncorrected distance visual acuity increased approximately two lines (approximately 20/63 to 20/40 Snellen), and corrected distance visual acuity in 4 (80%) eyes gained one line, 2 (40%) eyes gained two lines, and 1 (20%) eye gained more than two lines. There was no significant difference (P > .05) in spherical equivalent compared with 1 day postoperatively and the last follow-up visit. Corneal topography showed that the lenticule was uniform and located well; anterior segment optical coherence tomography images showed that the lenticule was transparent and the demarcation line was visible. Implanting an autologous lenticule obtained by small incision lenticule extraction for hyperopia might be safe, effective, and stable, but its predictability should be improved in the future. Copyright 2015, SLACK Incorporated.

  9. Linkage analysis of quantitative refraction and refractive errors in the Beaver Dam Eye Study.

    PubMed

    Klein, Alison P; Duggal, Priya; Lee, Kristine E; Cheng, Ching-Yu; Klein, Ronald; Bailey-Wilson, Joan E; Klein, Barbara E K

    2011-07-13

    Refraction, as measured by spherical equivalent, is the need for an external lens to focus images on the retina. While genetic factors play an important role in the development of refractive errors, few susceptibility genes have been identified. However, several regions of linkage have been reported for myopia (2q, 4q, 7q, 12q, 17q, 18p, 22q, and Xq) and for quantitative refraction (1p, 3q, 4q, 7p, 8p, and 11p). To replicate previously identified linkage peaks and to identify novel loci that influence quantitative refraction and refractive errors, linkage analysis of spherical equivalent, myopia, and hyperopia in the Beaver Dam Eye Study was performed. Nonparametric, sibling-pair, genome-wide linkage analyses of refraction (spherical equivalent adjusted for age, education, and nuclear sclerosis), myopia and hyperopia in 834 sibling pairs within 486 extended pedigrees were performed. Suggestive evidence of linkage was found for hyperopia on chromosome 3, region q26 (empiric P = 5.34 × 10(-4)), a region that had shown significant genome-wide evidence of linkage to refraction and some evidence of linkage to hyperopia. In addition, the analysis replicated previously reported genome-wide significant linkages to 22q11 of adjusted refraction and myopia (empiric P = 4.43 × 10(-3) and 1.48 × 10(-3), respectively) and to 7p15 of refraction (empiric P = 9.43 × 10(-4)). Evidence was also found of linkage to refraction on 7q36 (empiric P = 2.32 × 10(-3)), a region previously linked to high myopia. The findings provide further evidence that genes controlling refractive errors are located on 3q26, 7p15, 7p36, and 22q11.

  10. Changes in Keratometric Values and Corneal High Order Aberrations After Hydrogel Inlay Implantation.

    PubMed

    Whang, Woong-Joo; Yoo, Young-Sik; Joo, Choun-Ki; Yoon, Geunyoung

    2017-01-01

    We sought to analyze surgically induced refractive change (SIRC) and change in high-order aberration after Raindrop corneal inlay insertion (ReVision Optics, Lake Forest, CA), and assess the extent to which Raindrop corneal inlay insertion could correct presbyopia. Interventional case series. Seventeen patients were included if they had a corneal thickness ≥500 μm and a stable manifest spherical equivalent refraction between 0.50 and +1.00 diopters (D). The Raindrop corneal inlay was implanted on the stromal bed of a femtosecond laser-assisted generated flap of nondominant eyes. Manifest refraction, corneal powers, and corneal high-order aberrations were measured preoperatively and at 3 and 12 months postoperatively. The SIRC by manifest refraction was 0.99 ± 0.26 D. The changes derived from simulated keratometry (K), true net power, and equivalent K reading (EKR) at 1.0-4.0 mm were greater than the SIRC (all P < .01) while the change in EKR at 6.0 mm was less than the SIRC (P < .01). The changes in EKR 5.0 mm, automated K, and EKR 4.5 mm did not differ significantly from the SIRC (P = .81, .29, and .09, respectively), and the difference was the least for EKR 5.0 mm. In analysis of high-order aberrations, only spherical aberration showed statistically significant difference between preoperative and postoperative on both anterior cornea and total cornea (all P < .01). Raindrop corneal inlay corrects presbyopia via increasing negative spherical aberration. The equivalent K reading at 5.0 mm accurately reflected the SIRC, and would be applicable for intraocular power prediction before cataract surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Performance of Photoscreener in Detection of Refractive Error in All Age Groups and Amblyopia Risk Factors in Children in a Tribal District of Odisha: The Tribal Odisha Eye Disease Study (TOES) # 3

    PubMed Central

    Panda, Lapam; Barik, Umasankar; Nayak, Suryasmita; Barik, Biswajit; Behera, Gyanaranjan; Kekunnaya, Ramesh

    2018-01-01

    Purpose To evaluate effectiveness of Welch Allyn Spot Vision Screener in detecting refractive error in all age groups and amblyopia risk factors in children in a tribal district of India. Methods All participants received dry retinoscopy and photorefraction; children also received cycloplegic retinoscopy. Statistical analysis included Bland-Altman and coefficient of determination (R2). Results Photoscreener could not elicit a response in 113 adults and 5 children of 580 recruited participants. In Bland-Altman analysis mean difference of Spot screener spherical equivalent (SSSE) and dry retinoscopy spherical equivalent (DRSE) was 0.32 diopters (D) in adults and 0.18 D in children; this was an overestimation of hyperopia and underestimation of myopia. In Bland-Altman analysis of SSSE and cycloplegic retinoscopy spherical equivalent (CRSE) the mean difference was −0.30 D in children; this was an overestimation of myopia and underestimation of hyperopia. In regression analysis the relationship between SSSE and DRSE was poor in adults (R2 = 0.50) and good in children (R2 = 0.92). Cubic regression model for Spot versus cycloretinoscopy in children was: CRSE = 0.34 + 0.85 SSSE − 0.01 SSSE2 + 0.006 SSSE3. It was 87% accurate. Sensitivity and specificity of Spot in detecting amblyopia risk factors (2013 American Association for Pediatric Ophthalmology and Strabismus [AAPOS] criteria) was 93.3% and 96.9% respectively. Sensitivity of Spot screener in detection of amblyopia was 72%. Conclusions Photoscreener has 87% accuracy in refraction in children. Its value could be used for subjective correction tests. Translational Relevance Photoscreening could complement traditional retinoscopy to address refractive error in children in a resource-limited facility region. PMID:29881649

  12. Longitudinal comparison of outcomes after sub-Bowman keratomileusis and laser in situ keratomileusis: randomized, double-masked study.

    PubMed

    Wong, Rachel Chung Yin; Yu, Marco; Chan, Tommy C Y; Chong, Kelvin K L; Jhanji, Vishal

    2015-05-01

    To compare the outcomes of sub-Bowman keratomileusis (100-μm flap) and laser in situ keratomileusis (LASIK) (120-μm flap) using 150-kHz femtosecond laser. Randomized, double-masked, contralateral clinical trial. One hundred patients (200 eyes) with myopia or myopic astigmatism were included. Postoperative examinations were performed at week 1 and months 1, 3, 6, and 12. Main outcome measures included postoperative uncorrected (UCVA) and best-corrected distance visual acuity (BCVA); manifest refraction spherical equivalent; efficacy and safety indices; corneal thickness; and complications. The mean age of patients was 33.9 ± 7.9 years. Overall, the preoperative UCVA, BCVA, and manifest refraction spherical equivalent were 1.349 ± 0.332, -0.022 ± 0.033, and -5.81 ± 1.61 diopters, respectively. No significant difference was observed in preoperative (P ≥ .226) or intraoperative parameters (P ≥ .452) between both groups, except residual stromal thickness (P < .001). The UCVA, manifest refraction spherical equivalent, and central corneal thickness stabilized by 1 week, while the thinnest corneal thickness stabilized by 3 months postoperatively. There was no significant difference between both groups for any parameter during all follow-up visits (P ≥ .132) except the 3-month safety index, which was better in the sub-Bowman keratomileusis group (P = .007). Soft opaque bubble layer was noted intraoperatively in 12 cases (7, 100-μm group; 5, 120-μm group; P = .577). No postoperative complications were observed. Our study did not find any differences in the visual and refractive outcomes between femtosecond-assisted sub-Bowman keratomileusis and LASIK. Both surgeries resulted in quick visual recovery as early as 1 week postoperatively. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Refractive errors in 3-6 year-old Chinese children: a very low prevalence of myopia?

    PubMed

    Lan, Weizhong; Zhao, Feng; Lin, Lixia; Li, Zhen; Zeng, Junwen; Yang, Zhikuan; Morgan, Ian G

    2013-01-01

    To examine the prevalence of refractive errors in children aged 3-6 years in China. Children were recruited for a trial of a home-based amblyopia screening kit in Guangzhou preschools, during which cycloplegic refractions were measured in both eyes of 2480 children. Cycloplegic refraction (from 3 to 4 drops of 1% cyclopentolate to ensure abolition of the light reflex) was measured by both autorefraction and retinoscopy. Refractive errors were defined as followed: myopia (at least -0.50 D in the worse eye), hyperopia (at least +2.00 D in the worse eye) and astigmatism (at least 1.50 D in the worse eye). Different definitions, as specified in the text, were also used to facilitate comparison with other studies. The mean spherical equivalent refractive error was at least +1.22 D for all ages and both genders. The prevalence of myopia for any definition at any age was at most 2.5%, and lower in most cases. In contrast, the prevalence of hyperopia was generally over 20%, and declined slightly with age. The prevalence of astigmatism was between 6% and 11%. There was very little change in refractive error with age over this age range. Previous reports of less hyperopic mean spherical equivalent refractive error, and more myopia and less hyperopia in children of this age may be due to problems with achieving adequate cycloplegia in children with dark irises. Using up to 4 drops of 1% cyclopentolate may be necessary to accurately measure refractive error in paediatric studies of such children. Our results suggest that children from all ethnic groups may follow a similar pattern of early refractive development, with little myopia and a hyperopic mean spherical equivalent over +1.00 D up to the age of 5-6 years in most conditions.

  14. Prevalence of the refractive errors by age and gender: the Mashhad eye study of Iran.

    PubMed

    Ostadimoghaddam, Hadi; Fotouhi, Akbar; Hashemi, Hassan; Yekta, Abbasali; Heravian, Javad; Rezvan, Farhad; Ghadimi, Hamidreza; Rezvan, Bijan; Khabazkhoob, Mehdi

    2011-11-01

    Refractive errors are a common eye problem. Considering the low number of population-based studies in Iran in this regard, we decided to determine the prevalence rates of myopia and hyperopia in a population in Mashhad, Iran. Cross-sectional population-based study. Random cluster sampling. Of 4453 selected individuals from the urban population of Mashhad, 70.4% participated. Refractive error was determined using manifest (age > 15 years) and cycloplegic refraction (age ≤ 15 years). Myopia was defined as a spherical equivalent of -0.5 diopter or worse. An spherical equivalent of +0.5 diopter or worse for non-cycloplegic refraction and an spherical equivalent of +2 diopter or worse for cycloplegic refraction was used to define hyperopia. Prevalence of refractive errors. The prevalence of myopia and hyperopia in individuals ≤ 15 years old was 3.64% (95% CI: 2.19-5.09) and 27.4% (95% CI: 23.72-31.09), respectively. The same measurements for subjects > 15 years of age was 22.36% (95% CI: 20.06-24.66) and 34.21% (95% CI: 31.57-36.85), respectively. Myopia was found to increase with age in individuals ≤ 15 years and decrease with age in individuals > 15 years of age. The rate of hyperopia showed a significant increase with age in individuals > 15 years. The prevalence of astigmatism was 25.64% (95% CI: 23.76-27.51). In children and the elderly, hyperopia is the most prevalent refractive error. After hyperopia, astigmatism is also of importance in older ages. Age is the most important demographic factor associated with different types of refractive errors. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.

  15. Assessment of corneal biomechanical properties and intraocular pressure in myopic spanish healthy population.

    PubMed

    Del Buey, María A; Lavilla, Laura; Ascaso, Francisco J; Lanchares, Elena; Huerva, Valentín; Cristóbal, José A

    2014-01-01

    Purpose. To examine biomechanical parameters of the cornea in myopic eyes and their relationship with the degree of myopia in a western healthy population. Methods. Corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann correlated intraocular pressure (IOP), and corneal compensated IOP (IOPcc) were measured using the ocular response analyzer (ORA) in 312 eyes of 177 Spanish subjects aged between 20 and 56 years. Refraction was expressed as spherical equivalent (SE), which ranged from 0 to -16.50 diopters (D) (mean: -3.88 ± 2.90 D). Subjects were divided into four groups according to their refractive status: group 1 or control group: emmetropia (-0.50 ≤ SE < 0.50); group 2: low myopia (-0.75 ≤ SE < 3.00 D); group 3: moderate myopia (-3.00 ≤ SE ≤ -6.00 D); and group 3: high myopia (SE greater than -6.00 D). We analyzed the relationship between corneal biomechanics measured with ORA and SE. Results. CH in the emmetropia, low myopia, moderate myopia, and high myopia groups was 11.13 ± 0.98, 11.49 ± 1.25, 10.52 ± 1.54, and 10.35 ± 1.33 mmHg, respectively. CH in the highly myopic group was significantly lower than that in the emmetropic group (P = 0.07) and low myopic group (P = 0.035); however, there were no differences with the moderate myopic group (P = 0.872). There were no statistically significant differences regarding IOP among the four groups (P > 0.05); nevertheless, IOPcc was significantly higher in the moderately myopic (15.47 ± 2.47 mmHg) and highly myopic (16.14 ± 2.59 mmHg) groups than in the emmetropia (15.15 ± 2.06 mmHg) and low myopia groups (14.53 ± 2.37 mmHg). No correlation between age and the measured parameters was found. CH and IOPcc were weakly but significantly correlated with SE (r = 0.171, P = 0.002 and r = -0.131, P = 0.021, resp.). Conclusions. Present study showed only a very weak, but significant, correlation between CH and refractive error, with CH being lower in both moderately and highly myopic eyes than that in the emmetropic and low myopic eyes. These changes in biomechanical properties of the cornea may have an impact on IOP measurement, increasing the risk of glaucoma.

  16. Spherical aberrations of human astigmatic corneas.

    PubMed

    Zhao, Huawei; Dai, Guang-Ming; Chen, Li; Weeber, Henk A; Piers, Patricia A

    2011-11-01

    To evaluate whether the average spherical aberration of human astigmatic corneas is statistically equivalent to human nonastigmatic corneas. Spherical aberrations of 445 astigmatic corneas prior to laser vision correction were retrospectively investigated to determine Zernike coefficients for central corneal areas 6 mm in diameter using CTView (Sarver and Associates). Data were divided into groups according to cylinder power (0.01 to 0.25 diopters [D], 0.26 to 0.75 D, 0.76 to 1.06 D, 1.07 to 1.53 D, 1.54 to 2.00 D, and >2.00 D) and according to age by decade. Spherical aberrations were correlated with age and astigmatic power among groups and the entire population. Statistical analyses were conducted, and P<.05 was considered statistically significant. Mean patient age was 42.6±11 years. Astigmatic corneas had an average astigmatic power of 0.78±0.58 D and mean spherical aberration was 0.25±0.13 μm for the entire population and approximately the same (0.27 μm) for individual groups, ranging from 0.23 to 0.29 μm (P>.05 for all tested groups). Mean spherical aberration of astigmatic corneas was not correlated significantly with cylinder power or age (P>.05). Spherical aberrations are similar to those of nonastigmatic corneas, permitting the use of these additional data in the design of aspheric toric intra-ocular lenses. Copyright 2011, SLACK Incorporated.

  17. Efficacy and safety of deep anterior lamellar keratoplasty vs. penetrating keratoplasty for keratoconus: a meta-analysis.

    PubMed

    Liu, Hao; Chen, Yihui; Wang, Peng; Li, Bing; Wang, Weifang; Su, Yan; Sheng, Minjie

    2015-01-01

    To evaluate difference in therapeutic outcomes between deep anterior lamellar keratoplasty (DALK) and penetrating keratoplasty (PKP) for the clinical treatment of keratoconus. A comprehensive search was conducted in Pubmed, EMBASE, Cochrane Library, and Web of science. Eligible studies should include at least one of the following factors: best corrected visual acuity (BCVA), postoperative spherical equivalent (SE), postoperative astigmatism and endothelial cell count (ECC), central corneal thickness (CCT), graft rejection and graft failure, of which BCVA, graft rejection and graft failure were used as the primary outcome measures, and postoperative SE, astigmatism, CCT and ECC as the secondary outcome measures. Given the lack of randomized clinical trials (RCTs), cohort studies and prospective studies were considered eligible. Sixteen clinical trials involving 6625 eyes were included in this review, including 1185 eyes in DALK group, and 5440 eyes in PKP group. The outcomes were analyzed using Cochrane Review Manager (RevMan) version 5.0 software. The postoperative BCVA in DALK group was significantly better than that in PKP group (OR = 0.48; 95%CI 0.39 to 0.60; p<0.001). There were fewer cases of graft rejection in DALK group than those in PKP group (OR = 0.28; 95%CI 0.15 to 0.50; p<0.001). Nevertheless the rate of graft failure was similar between DALK and PKP groups (OR = 1.05; 95%CI 0.81 to 1.36; p = 0.73). There were no significant differences in the secondary outcomes of SE (p = 0.70), astigmatism (p = 0.14) and CCT (p = 0.58) between DALK and PKP groups. And ECC in DALK group was significantly higher than PKP group (p<0.001). The postoperative complications, high intraocular pressure (high-IOP) and cataract were analyzed, fewer cases of complications occurred in DALK group than those in PKP group (high-IOP, OR 0.22, 95% CI 0.11-0.44, P<0.001) (cataract, OR 0.22; 95% CI 0.08-0.61, P = 0.004). And no cases of expulsive hemorrhage and endophthalmitis were reported. The visual outcomes for DALK were not equivalent to PKP. The rate of graft failure was similar between DALK and PKP. Fewer postoperative complications occurred in DALK group, indicating that compared with PKP, DALK has lower efficacy but higher safety.

  18. SEDIDAT: A BASIC program for the collection and statistical analysis of particle settling velocity data

    NASA Astrophysics Data System (ADS)

    Wright, Robyn; Thornberg, Steven M.

    SEDIDAT is a series of compiled IBM-BASIC (version 2.0) programs that direct the collection, statistical calculation, and graphic presentation of particle settling velocity and equivalent spherical diameter for samples analyzed using the settling tube technique. The programs follow a menu-driven format that is understood easily by students and scientists with little previous computer experience. Settling velocity is measured directly (cm,sec) and also converted into Chi units. Equivalent spherical diameter (reported in Phi units) is calculated using a modified Gibbs equation for different particle densities. Input parameters, such as water temperature, settling distance, particle density, run time, and Phi;Chi interval are changed easily at operator discretion. Optional output to a dot-matrix printer includes a summary of moment and graphic statistical parameters, a tabulation of individual and cumulative weight percents, a listing of major distribution modes, and cumulative and histogram plots of a raw time, settling velocity. Chi and Phi data.

  19. Antibacterial effect of the laser-generated Se nanocoatings on Staphylococcus aureus and Pseudomonas aeruginosa biofilms

    NASA Astrophysics Data System (ADS)

    Ionin, A. A.; Ivanova, A. K.; Khmel'nitskii, R. A.; Klevkov, Yu V.; Kudryashov, S. I.; Levchenko, A. O.; Nastulyavichus, A. A.; Rudenko, A. A.; Saraeva, I. N.; Smirnov, N. A.; Zayarny, D. A.; Gonchukov, S. A.; Tolordava, E. R.

    2018-01-01

    The antibacterial properties of selenium nanoparticles (Se NPs) were successfully demonstrated in vitro for Staphylococcus aureus and Pseudomonas aeruginosa biofilms. The possible mechanisms of antibacterial impact included the emergence of reactive oxygen species, induced by free radicals on the NP surface and accompanied by subsequent oxidative stress, as well as mechanical decomposition of the mitochondrial membrane. Se nanocoatings were deposited on bare and silver-coated silica glass substrates via inkjet printing with concentrated nanoinks, prepared by infrared laser-ablative processing of a solid Se target in a 50%-isopropyl solution. The resulted porous nanofilms with high-percentage surface coverage, consisting of spherical Se NPs and Se nanorods, were characterized by means of standard microscopy techniques (optical, scanning electron, transmission), UV-vis-IR and EDX spectroscopy.

  20. Communication—indentation of Li-ion pouch cell: Effect of material homogenization on prediction of internal short circuit

    DOE PAGES

    Kumar, A.; Kalnaus, Sergiy; Simunovic, Srdjan; ...

    2016-09-12

    We performed finite element simulations of spherical indentation of Li-ion pouch cells. Our model fully resolves different layers in the cell. The results of the layer resolved models were compared to the models available in the literature that treat the cell as an equivalent homogenized continuum material. Simulations were carried out for different sizes of the spherical indenter. Here, we show that calibration of a failure criterion for the cell in the homogenized model depends on the indenter size, whereas in the layer-resoled model, such dependency is greatly diminished.

  1. Prevalence of refractive errors and associated risk factors in subjects with type 2 diabetes mellitus SN-DREAMS, report 18.

    PubMed

    Rani, Padmaja Kumari; Raman, Rajiv; Rachapalli, Sudhir R; Kulothungan, Vaitheeswaran; Kumaramanickavel, Govindasamy; Sharma, Tarun

    2010-06-01

    To report the prevalence of refractive errors and the associated risk factors in subjects with type 2 diabetes mellitus from an urban Indian population. Population-based, cross-sectional study. One thousand eighty participants selected from a pool of 1414 subjects with diabetes. A population-based sample of 1414 persons (age >40 years) with diabetes (identified as per the World Health Organization criteria) underwent a comprehensive eye examination, including objective and subjective refractions. One thousand eighty subjects who were phakic in the right eye with best corrected visual acuity of > or =20/40 were included in the analysis for prevalence of refractive errors. Univariate and multivariate analyses were done to find out the independent risk factors associated with the refractive errors. The mean refraction was +0.20+/-1.72, and the Median, +0.25 diopters. The prevalence of emmetropia (spherical equivalent [SE], -0.50 to +0.50 diopter sphere [DS]) was 39.26%. The prevalence of myopia (SE <-0.50 DS), high myopia (SE <-5.00 DS), hyperopia (SE >+0.50 DS), and astigmatism (SE <-0.50 cyl) was 19.4%, 1.6%, 39.7%, and 47.4%, respectively. The advancing age was an important risk factor for the three refractive errors: for myopia, odds ratio (OR; 95% confidence interval [CI] 4.06 [1.74-9.50]; for hyperopia, OR [95% CI] 5.85 [2.56-13.39]; and for astigmatism, OR [95% CI] 2.51 [1.34-4.71]). Poor glycemic control was associated with myopia (OR [95% CI] 4.15 [1.44-11.92]) and astigmatism (OR [95% CI] 2.01 [1.04-3.88]). Female gender was associated with hyperopia alone) OR [95% CI] 2.00 [1.42-2.82]. The present population-based study from urban India noted a high prevalence of refractive errors (60%) among diabetic subjects >40 years old; the prevalence of astigmatism (47%) was higher than hyperopia (40%) or myopia (20%). Copyright 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  2. Relationship between visual field progression and baseline refraction in primary open-angle glaucoma.

    PubMed

    Naito, Tomoko; Yoshikawa, Keiji; Mizoue, Shiro; Nanno, Mami; Kimura, Tairo; Suzumura, Hirotaka; Umeda, Yuzo; Shiraga, Fumio

    2016-01-01

    To analyze the relationship between visual field (VF) progression and baseline refraction in Japanese patients with primary open-angle glaucoma (POAG) including normal-tension glaucoma. In this retrospective study, the subjects were patients with POAG who had undergone VF tests at least ten times with a Humphrey Field Analyzer (Swedish interactive thresholding algorithm standard, Central 30-2 program). VF progression was defined as a significantly negative value of mean deviation (MD) slope at the final VF test. Multivariate logistic regression models were applied to detect an association between MD slope deterioration and baseline refraction. A total of 156 eyes of 156 patients were included in this analysis. Significant deterioration of MD slope was observed in 70 eyes of 70 patients (44.9%), whereas no significant deterioration was evident in 86 eyes of 86 patients (55.1%). The eyes with VF progression had significantly higher baseline refraction compared to those without apparent VF progression (-1.9±3.8 diopter [D] vs -3.5±3.4 D, P=0.0048) (mean ± standard deviation). When subject eyes were classified into four groups by the level of baseline refraction applying spherical equivalent (SE): no myopia (SE > -1D), mild myopia (-1D ≥ SE > -3D), moderate myopia (-3D ≥ SE > -6D), and severe myopia (-6D ≥ SE), the Cochran-Armitage trend analysis showed a decreasing trend in the proportion of MD slope deterioration with increasing severity of myopia (P=0.0002). The multivariate analysis revealed that baseline refraction (P=0.0108, odds ratio [OR]: 1.13, 95% confidence interval [CI]: 1.03-1.25) and intraocular pressure reduction rate (P=0.0150, OR: 0.97, 95% CI: 0.94-0.99) had a significant association with MD slope deterioration. In the current analysis of Japanese patients with POAG, baseline refraction was a factor significantly associated with MD slope deterioration as well as intraocular pressure reduction rate. When baseline refraction was classified into four groups, MD slope in myopia groups was less deteriorated as compared to those in the emmetropic/hyperopic group.

  3. Hierarchical nanoparticle assemblies formed by decorating breath figures.

    PubMed

    Böker, Alexander; Lin, Yao; Chiapperini, Kristen; Horowitz, Reina; Thompson, Mike; Carreon, Vincent; Xu, Ting; Abetz, Clarissa; Skaff, Habib; Dinsmore, A D; Emrick, Todd; Russell, Thomas P

    2004-05-01

    The combination of two self-assembly processes on different length scales leads to the formation of hierarchically structured nanoparticle arrays. Here, the formation of spherical cavities, or 'breath figures'-made by the condensation of micrometre-sized water droplets on the surface of a polymer solution-that self-assemble into a well-ordered hexagonal array, is combined with the self-assembly of CdSe nanoparticles at the polymer solution-water droplet interface. Complete evaporation of the solvent and water confines the particle assembly to an array of spherical cavities and allows for ex situ investigation. Fluorescence confocal, transmission electron and scanning electron microscope images show the preferential segregation of the CdSe nanoparticles to the polymer solution-water interface where they form a 5-7-nm-thick layer, thus functionalizing the walls of the holes. This process opens a new route to fabricating highly functionalized ordered microarrays of nanoparticles, potentially useful in sensory, separation membrane or catalytic applications.

  4. XFEM with equivalent eigenstrain for matrix-inclusion interfaces

    NASA Astrophysics Data System (ADS)

    Benvenuti, Elena

    2014-05-01

    Several engineering applications rely on particulate composite materials, and numerical modelling of the matrix-inclusion interface is therefore a crucial part of the design process. The focus of this work is on an original use of the equivalent eigenstrain concept in the development of a simplified eXtended Finite Element Method. Key points are: the replacement of the matrix-inclusion interface by a coating layer with small but finite thickness, and its simulation as an inclusion with an equivalent eigenstrain. For vanishing thickness, the model is consistent with a spring-like interface model. The problem of a spherical inclusion within a cylinder is solved. The results show that the proposed approach is effective and accurate.

  5. The Intravitreal Autologous Platelet Concentrate Injection as an Adjunct of Vitrectomy for the Treatment of Refractory Macular Holes

    ClinicalTrials.gov

    2014-03-06

    Macular Hole With High Myopia (Spherical Equivalent ≤ -6.0 Diopters) or,; Large Size Macular Hole (Diameter > 600 Microns) or; Recurred or Failed Macular Hole From Previous Surgery; or Chronic Macular Hole (Symptom Duration > 6 Months)

  6. Clinical results of the laser-assisted in situ keratomileusis (LASIK) for myopia

    NASA Astrophysics Data System (ADS)

    Guo, Hai-ke; Yao, Da-qing; Gui, Lu-ping

    1998-11-01

    To observe and analyze the refractive and complications of the LASIK for corrections of myopia. With the microlamellar keratoplasty and the excimer laser, LASIK was performed on 194 cases. According to the preoperative spherical equivalent refraction, divide the patients into three groups.

  7. Spherical D-brane by tachyon condensation

    NASA Astrophysics Data System (ADS)

    Asakawa, Tsuguhiko; Matsuura, So

    2018-03-01

    We find a novel tachyon condensation which provides a D-brane system with spherical worldvolume in the flat spacetime. The tachyon profile is a deformation of a known D0-brane solution on non-BPS D3-branes in type IIA superstring theory, which realizes a bound state of a spherical D2-brane and a D0-brane. The D0-brane is resolved into the sphere as a U(1) monopole flux of the unit magnetic charge. We show that the system has the correct tension and the RR-coupling. Although the low-energy effective action of the system is the same as that of the dual description of the fuzzy sphere solution of multiple D0-branes, our system cannot be equivalent to the fuzzy sphere. The use of projective modules in describing the tachyon condensation is emphasized.

  8. Electrochemical studies on niobium triselenide cathode material for lithium rechargeable cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ratnakumar, B.V.; Ni, C.L.; DiStefano, S.

    1989-01-01

    Niobium triselenide offers promise as a high energy density cathode material for ambient temperature lithium rechargeable cells. The electrochemical behavior of NbSe/sub 3/ in the battery electrolyte, i.e., 1.5m LiAsF/sub 6//2 Me-THF is reported here. A detailed study has been carried out using various ac and dc electrochemical techniques to establish the mechanism of intercalation of three equivalents of Li with NbSe/sub 3/ as well as the rate governing processes in the reduction of NbSe/sub 3/. Based on the experimental data, an equivalent circuit has been formulated to represent the NbSe/sub 3/-solution interface. The kinetic parameters for the reduction ofmore » NbSe/sub 3/ were evaluated from the ac and dc measurements. Finally, the structural change in NbSe/sub 3/ on lithiation during initial discharge which results in higher cell voltages and different electrochemical response as compared to virgin NbSe/sub 3/ was identified to be a loss of crystallographic order, i.e., amorphous by x-ray diffraction.« less

  9. Light scattering by nonspherical particles: Remote sensing and climatic implications

    NASA Astrophysics Data System (ADS)

    Liou, K. N.; Takano, Y.

    Calculations of the scattering and adsorption properties of ice crystals and aerosols, which are usually nonspherical, require specific methodologies. There is no unique theoretical solution for the scattering by nonspherical particles. Practically, all the numerical solutions for the scattering of nonspherical particles, including the exact wave equation approach, integral equation method, and discrete-dipole approximation, are applicable only to size parameters less than about 20. Thus, these methods are useful for the study of radiation problems involving nonspherical aerosols and small ice crystals in the thermal infrared wavelengths. The geometric optics approximation has been used to evaluate the scattering, absorption and polarization properties of hexagonal ice crystals whose sizes are much larger than the incident wavelength. This approximation is generally valid for hexagonal ice crystals with size parameters larger than about 30. From existing laboratory data and theoretical results, we illustrate that nonspherical particles absorb less and have a smaller asymmetry factor than the equal-projected area/volume spherical counterparts. In particular, we show that hexagonal ice crystals exhibit numerous halo and arc features that cannot be obtained from spherical particles; and that ice crystals scatter more light in the 60° to 140° scattering angle regions than the spherical counterparts. Satellite remote sensing of the optical depth and height of cirrus clouds using visible and IR channels must use appropriate phase functions for ice crystals. Use of an equivalent sphere model would lead to a significant overestimation and underestimation of the cirrus optical depth and height, respectively. Interpretation of the measurements for polarization reflected from sunlight involving cirrus clouds cannot be made without an appropriate ice crystal model. Large deviations exist for the polarization patterns between spheres and hexagonal ice crystals. Interpretation of lidar backscattering and depolarization signals must also utilize the scattering characteristics of hexagonal ice crystals. Equivalent spherical models substantially underestimate the broadband solar albedos of ice crystal clouds because of stronger forward scattering and larger absorption by spherical particles than hexagonal ice crystals. We illustrate that the net cloud radiative forcing at the top of the atmosphere involving most cirrus clouds is positive, implying that the IR greenhouse effect outweighs the solar albedo effect. If the radiative properties of equivalent spheres are used, a significant increase in cloud radiative forcing occurs. Using a one-dimensional cloud and climate model, we further demonstrate that there is sufficient model sensitivity, in terms of temperature increase, to the use of ice crystal models in radiation calculations.

  10. Prevalence and associations of anisometropia with spherical ametropia, cylindrical power, age, and sex in refractive surgery candidates.

    PubMed

    Linke, Stephan J; Richard, Gisbert; Katz, Toam

    2011-09-29

    To analyze the prevalence and associations of anisometropia with spherical ametropia, astigmatism, age, and sex in a refractive surgery population. Medical records of 27,070 eyes of 13,535 refractive surgery candidates were reviewed. Anisometropia, defined as the absolute difference in mean spherical equivalent powers between right and left eyes, was analyzed for subjective (A(subj)) and cycloplegic refraction (A(cycl)). Correlations between anisometropia (>1 diopter) and spherical ametropia, cylindrical power, age, and sex, were analyzed using χ² and nonparametric Kruskal-Wallis or Mann-Whitney tests and binomial logistic regression analyses. Power vector analysis was applied for further analysis of cylindrical power. Prevalence of A(subj) was 18.5% and of A(cycl) was 19.3%. In hyperopes, logistic regression analysis revealed that only spherical refractive error (odds ratio [OR], 0.72) and age (OR, 0.97) were independently associated with anisometropia. A(subj) decreased with increasing spherical ametropia and advancing age. Cylindrical power and sex did not significantly affect A(subj). In myopes all explanatory variables (spherical power OR, 0.93; cylindrical power OR, 0.75; age OR, 1.02; sex OR, 0.8) were independently associated with anisometropia. Cylindrical power was most strongly associated with anisometropia. Advancing age and increasing spherical/cylindrical power correlated positively with increasing anisometropia in myopic subjects. Female sex was more closely associated with anisometropia. This large-scale retrospective analysis confirmed an independent association between anisometropia and both spherical ametropia and age in refractive surgery candidates. Notably, an inverse relationship between these parameters in hyperopes was observed. Cylindrical power and female sex were independently associated with anisometropia in myopes.

  11. Distance vision after bilateral implantation of AcrySof toric intraocular lenses: a randomized, controlled, prospective trial

    PubMed Central

    Zhang, Jin-Song; Zhao, Jiang-Yue; Sun, Qi; Ma, Li-Wei

    2011-01-01

    AIM To evaluate the distance vision of Chinese patients with cataracts and corneal astigmatism after implantation of bilateral AcrySof toric intraocular lens (IOL) versus bilateral AcrySof spherical IOL. METHODS This study randomized 60 patients into equal groups to receive toric IOL or spherical IOL. IOL powers targeting emmetropia were selected for 93% of toric IOL patients and for 90% of spherical IOL patients. Assessments included monocular and binocular distance vision, with and without best correction. Patients also completed surveys about their distance vision. RESULTS Preoperatively, the two study groups were similar in age, in distance visual acuity, and in the magnitude of corneal astigmatism. At 6 months postoperative, binocular uncorrected distance vision was 0.06±0.14 logMAR in the AcrySof toric IOL group, significantly better than the 0.14±0.11 logMAR in the spherical IOL group (P<0.05). For eyes with emmetropia as a target, the equivalent of 20/20 uncorrected vision was more likely (P<0.001) in the toric IOL group (36% of eyes) than in the spherical IOL group (4% of eyes). No patients in the emmetropia/toric IOL group used distance glasses, as compared to 52% of patients in the emmetropia/spherical IOL group. All patients were satisfied or highly satisfied. Quality of distance vision was rated higher by toric IOL patients than by spherical IOL patients (P<0.05). CONCLUSION Bilateral AcrySof toric IOL is superior to bilateral spherical IOL in providing uncorrected distance vision to cataract patients with corneal astigmatism. PMID:22553636

  12. A restricted proof that the weak equivalence principle implies the Einstein equivalence principle

    NASA Technical Reports Server (NTRS)

    Lightman, A. P.; Lee, D. L.

    1973-01-01

    Schiff has conjectured that the weak equivalence principle (WEP) implies the Einstein equivalence principle (EEP). A proof is presented of Schiff's conjecture, restricted to: (1) test bodies made of electromagnetically interacting point particles, that fall from rest in a static, spherically symmetric gravitational field; (2) theories of gravity within a certain broad class - a class that includes almost all complete relativistic theories that have been found in the literature, but with each theory truncated to contain only point particles plus electromagnetic and gravitational fields. The proof shows that every nonmentric theory in the class (every theory that violates EEP) must violate WEP. A formula is derived for the magnitude of the violation. It is shown that WEP is a powerful theoretical and experimental tool for constraining the manner in which gravity couples to electromagnetism in gravitation theories.

  13. 21 CFR 118.4 - Salmonella Enteritidis (SE) prevention measures.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 2 2012-04-01 2012-04-01 false Salmonella Enteritidis (SE) prevention measures. 118.4 Section 118.4 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... equivalent standard; (2) Environmental testing. (i) The pullet environment is tested for SE when pullets are...

  14. 21 CFR 118.4 - Salmonella Enteritidis (SE) prevention measures.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 2 2013-04-01 2013-04-01 false Salmonella Enteritidis (SE) prevention measures. 118.4 Section 118.4 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... equivalent standard; (2) Environmental testing. (i) The pullet environment is tested for SE when pullets are...

  15. 21 CFR 118.4 - Salmonella Enteritidis (SE) prevention measures.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 2 2014-04-01 2014-04-01 false Salmonella Enteritidis (SE) prevention measures. 118.4 Section 118.4 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... equivalent standard; (2) Environmental testing. (i) The pullet environment is tested for SE when pullets are...

  16. 21 CFR 118.4 - Salmonella Enteritidis (SE) prevention measures.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 2 2011-04-01 2011-04-01 false Salmonella Enteritidis (SE) prevention measures. 118.4 Section 118.4 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... equivalent standard; (2) Environmental testing. (i) The pullet environment is tested for SE when pullets are...

  17. 21 CFR 118.4 - Salmonella Enteritidis (SE) prevention measures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Salmonella Enteritidis (SE) prevention measures. 118.4 Section 118.4 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... equivalent standard; (2) Environmental testing. (i) The pullet environment is tested for SE when pullets are...

  18. Application of Modified Spin-Echo–based Sequences for Hepatic MR Elastography: Evaluation, Comparison with the Conventional Gradient-Echo Sequence, and Preliminary Clinical Experience

    PubMed Central

    Mariappan, Yogesh K.; Dzyubak, Bogdan; Glaser, Kevin J.; Venkatesh, Sudhakar K.; Sirlin, Claude B.; Hooker, Jonathan; McGee, Kiaran P.

    2017-01-01

    Purpose To (a) evaluate modified spin-echo (SE) magnetic resonance (MR) elastographic sequences for acquiring MR images with improved signal-to-noise ratio (SNR) in patients in whom the standard gradient-echo (GRE) MR elastographic sequence yields low hepatic signal intensity and (b) compare the stiffness values obtained with these sequences with those obtained with the conventional GRE sequence. Materials and Methods This HIPAA-compliant retrospective study was approved by the institutional review board; the requirement to obtain informed consent was waived. Data obtained with modified SE and SE echo-planar imaging (EPI) MR elastographic pulse sequences with short echo times were compared with those obtained with the conventional GRE MR elastographic sequence in two patient cohorts, one that exhibited adequate liver signal intensity and one that exhibited low liver signal intensity. Shear stiffness values obtained with the three sequences in 130 patients with successful GRE-based examinations were retrospectively tested for statistical equivalence by using a 5% margin. In 47 patients in whom GRE examinations were considered to have failed because of low SNR, the SNR and confidence level with the SE-based sequences were compared with those with the GRE sequence. Results The results of this study helped confirm the equivalence of SE MR elastography and SE-EPI MR elastography to GRE MR elastography (P = .0212 and P = .0001, respectively). The SE and SE-EPI MR elastographic sequences provided substantially improved SNR and stiffness inversion confidence level in 47 patients in whom GRE MR elastography had failed. Conclusion Modified SE-based MR elastographic sequences provide higher SNR MR elastographic data and reliable stiffness measurements; thus, they enable quantification of stiffness in patients in whom the conventional GRE MR elastographic sequence failed owing to low signal intensity. The equivalence of the three sequences indicates that the current diagnostic thresholds are applicable to SE MR elastographic sequences for assessing liver fibrosis. © RSNA, 2016 PMID:27509543

  19. Visual performance after conventional LASIK and wavefront-guided LASIK with iris-registration: results at 1 year

    PubMed Central

    Zhang, Jing; Zhou, Yue-Hua; Li, Rui; Tian, Lei

    2013-01-01

    AIM To compare visual performance of wavefront-guided laser in situ keratomileusis (LASIK) with iris-registration (Wg-LASIK group) and conventional LASIK (LASIK group) one year after surgery and analyze the correlation between wavefront aberrations and visual performance. METHODS Eight hundred and fifty-two myopic eyes of 430 patients were enrolled in this prospective study and divided into two groups: Wg-LASIK group (436 eyes) and LASIK group (416 eyes). A Wavescan Wavefront aberrometer was used to analyze Zernike coefficients and the root-mean-square (RMS) of higher order aberrations, and Optec 6500 visual function instrument was used to measure contrast sensitivity (CS) before and 3, 6, 12 months after surgery. RESULTS The mean spherical equivalent (SE) in Wg-LASIK group was significantly better than those in LASIK group one year after surgery (P=0.024). Wg-LASIK eyes showed better CS values than LASIK eyes at all spatial frequencies with and without glare after surgery (P all<0.01). Moreover, the increase of higher RMS (RMSh), coma, RMS3, RMS4, RMS5 in Wg-LASIK group were significantly lower than those in LASIK group 1 year after surgery (P all<0.05). The increase of coma, spherical aberration (SA), RMS3 and RMS4 in Wg-LASIK and coma and RMS3 in LASIK group were negatively correlated with reduction of contrast sensitivity 1 year after surgery. CONCLUSION A significant better visual performance is got in Wg-LASIK group compared with LASIK group 1 year after surgery, and the Wg-LASIK is particularly suitable for eyes with high-magnitude RMSh. PMID:23991386

  20. Comparison of 2 wavefront-guided excimer lasers for myopic laser in situ keratomileusis: one-year results.

    PubMed

    Yu, Charles Q; Manche, Edward E

    2014-03-01

    To compare laser in situ keratomileusis (LASIK) outcomes between 2 wavefront-guided excimer laser systems in the treatment of myopia. University eye clinic, Palo Alto, California, USA. Prospective comparative case series. One eye of patients was treated with the Allegretto Wave Eye-Q system (small-spot scanning laser) and the fellow eye with the Visx Star Customvue S4 IR system (variable-spot scanning laser). Evaluations included measurement of uncorrected visual acuity, corrected visual acuity, and wavefront aberrometry. One hundred eyes (50 patients) were treated. The mean preoperative spherical equivalent (SE) refraction was -3.89 diopters (D) ± 1.67 (SD) and -4.18 ± 1.73 D in the small-spot scanning laser group and variable-spot scanning laser group, respectively. There were no significant differences in preoperative higher-order aberrations (HOAs) between the groups. Twelve months postoperatively, all eyes in the small-spot scanning laser group and 92% in the variable-spot scanning laser group were within ±0.50 D of the intended correction (P = .04). At that time, the small-spot scanning laser group had significantly less spherical aberration (0.12 versus 0.15) (P = .04) and significantly less mean total higher-order root mean square (0.33 μm versus 0.40 μm) (P = .01). Subjectively, patients reported that the clarity of night and day vision was significantly better in the eye treated with the small-spot scanning laser. The predictability and self-reported clarity of vision of wavefront-guided LASIK were better with the small-spot scanning laser. Eyes treated with the small-spot scanning laser had significantly fewer HOAs. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  1. Light-weight spherical mirrors for Cherenkov detectors

    NASA Astrophysics Data System (ADS)

    Cisbani, E.; Colilli, S.; Crateri, R.; Cusanno, F.; Fratoni, R.; Frullani, S.; Garibaldi, F.; Giuliani, F.; Gricia, M.; Iodice, M.; Iommi, R.; Lucentini, M.; Mostarda, A.; Pierangeli, L.; Santavenere, F.; Urciuoli, G. M.; De Leo, R.; Lagamba, L.; Nappi, E.; Braem, A.; Vernin, P.

    2003-01-01

    Light-weight spherical mirrors have been appositely designed and built for the gas threshold Cherenkov detectors of the two Hall A spectrometers. The mirrors are made of a 1 mm thick aluminized plexiglass sheet, reinforced by a rigid backing consisting of a phenolic honeycomb sandwiched between two carbon fiber mats epoxy glued. The produced mirrors have a thickness equivalent to 0.55% of radiation length, and an optical slope error of about 5.5 mrad. These characteristics make these mirrors suitable for the implementation in Cherenkov threshold detectors. Ways to improve the mirror features are also discussed in view of their possible employment in RICH detectors.

  2. Nekrasov and Argyres-Douglas theories in spherical Hecke algebra representation

    NASA Astrophysics Data System (ADS)

    Rim, Chaiho; Zhang, Hong

    2017-06-01

    AGT conjecture connects Nekrasov instanton partition function of 4D quiver gauge theory with 2D Liouville conformal blocks. We re-investigate this connection using the central extension of spherical Hecke algebra in q-coordinate representation, q being the instanton expansion parameter. Based on AFLT basis together with intertwiners we construct gauge conformal state and demonstrate its equivalence to the Liouville conformal state, with careful attention to the proper scaling behavior of the state. Using the colliding limit of regular states, we obtain the formal expression of irregular conformal states corresponding to Argyres-Douglas theory, which involves summation of functions over Young diagrams.

  3. Low-Cost Lattice Matching Si Based Composite Substrates for HgCdTe

    DTIC Science & Technology

    2013-09-01

    211). ..............................................5 Figure 3. Relationship between calculated alloy compositions based on Se/CdTe BEP ratio and...Se:CdTe beam equivalent pressure ( BEP ) ratios. During CdSeTe growth, Se and Te are in competition for the same nucleation sites. If we assume that all...therefore, x(cal) = ΦSe/ΦCd = 2ΦSe/ΦCdTe, where Φ is the BEP of the material, measured by the nude ion gauge at the substrate position. Figure 3 shows the

  4. Effect of Chemicals on Morphology and Luminescence of CdSe Quantum Dots.

    PubMed

    Zhang, Xiao; Li, Xiaoyu; Zhang, Ruili; Yang, Ping

    2015-04-01

    CdSe quantum dots (QDs) with several morphologies were fabricated using various reaction sys- tems. In a trioctylamine (TOA) and octadecylphosphonic acid (ODPA) system, yellow-emitting (a photoluminescence (PL) peak wavelength of 583 nm) CdSe QDs revealed rod morphology and nar- row size distribution. When ODPA was replaced by tetradecylphosphonic acid (TDPA), red-emitting CdSe rods (a PL peak wavelength of 653 nm) with broad size distribution were fabricated. This is ascribed that the short carbon chain accelerated the growth of CdSe QDs. As a result, the use of ODPA resulted in CdSe QDs with high PL efficiency (3.1%). Furthermore, cubic-like CdSe QDs were created in a stearic acid (SA) and octadecene (ODE) reaction system. The PL efficiency of the QDs is low (0.2%). When hexadecylamine (HDA) was added in such SA and ODE reaction system, spherical CdSe QDs with narrow size distribution and high PL efficiency (3.4%) were prepared.

  5. 49 CFR 572.183 - Neck assembly.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... subpart E pendulum test fixture as shown in Figure U2-A in appendix A to this subpart, so that the... pendulum longitudinal centerline shown in Figure U2-A. Torque the half-spherical screws (175-2004) located... equivalent; (3) Release the pendulum from a height sufficient to allow it to fall freely to achieve an impact...

  6. 49 CFR 572.183 - Neck assembly.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... subpart E pendulum test fixture as shown in Figure U2-A in appendix A to this subpart, so that the... pendulum longitudinal centerline shown in Figure U2-A. Torque the half-spherical screws (175-2004) located... equivalent; (3) Release the pendulum from a height sufficient to allow it to fall freely to achieve an impact...

  7. 49 CFR 572.183 - Neck assembly.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... subpart E pendulum test fixture as shown in Figure U2-A in appendix A to this subpart, so that the... pendulum longitudinal centerline shown in Figure U2-A. Torque the half-spherical screws (175-2004) located... equivalent; (3) Release the pendulum from a height sufficient to allow it to fall freely to achieve an impact...

  8. 49 CFR 572.183 - Neck assembly.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... subpart E pendulum test fixture as shown in Figure U2-A in appendix A to this subpart, so that the... pendulum longitudinal centerline shown in Figure U2-A. Torque the half-spherical screws (175-2004) located... equivalent; (3) Release the pendulum from a height sufficient to allow it to fall freely to achieve an impact...

  9. 49 CFR 572.183 - Neck assembly.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... subpart E pendulum test fixture as shown in Figure U2-A in appendix A to this subpart, so that the... pendulum longitudinal centerline shown in Figure U2-A. Torque the half-spherical screws (175-2004) located... equivalent; (3) Release the pendulum from a height sufficient to allow it to fall freely to achieve an impact...

  10. Approximating lens power.

    PubMed

    Kaye, Stephen B

    2009-04-01

    To provide a scalar measure of refractive error, based on geometric lens power through principal, orthogonal and oblique meridians, that is not limited to the paraxial and sag height approximations. A function is derived to model sections through the principal meridian of a lens, followed by rotation of the section through orthogonal and oblique meridians. Average focal length is determined using the definition for the average of a function. Average univariate power in the principal meridian (including spherical aberration), can be computed from the average of a function over the angle of incidence as determined by the parameters of the given lens, or adequately computed from an integrated series function. Average power through orthogonal and oblique meridians, can be similarly determined using the derived formulae. The widely used computation for measuring refractive error, the spherical equivalent, introduces non-constant approximations, leading to a systematic bias. The equations proposed provide a good univariate representation of average lens power and are not subject to a systematic bias. They are particularly useful for the analysis of aggregate data, correlating with biological treatment variables and for developing analyses, which require a scalar equivalent representation of refractive power.

  11. Infrared backscattering

    NASA Technical Reports Server (NTRS)

    Bohren, Craig F.; Nevitt, Timothy J.; Singham, Shermila Brito

    1989-01-01

    All particles in the atmosphere are not spherical. Moreover, the scattering properties of randomly oriented nonspherical particles are not equivalent to those of spherical particles no matter how the term equivalent is defined. This is especially true for scattering in the backward direction and at the infrared wavelengths at which some atmospheric particles have strong absorption bands. Thus calculations based on Mie theory of infrared backscattering by dry or insoluble atmospheric particles are suspect. To support this assertion, it was noted that peaks in laboratory-measured infrared backscattering spectra show appreciable shifts compared with those calculated using Mie theory. One example is ammonium sulfate. Some success was had in modeling backscattering spectra of ammonium sulfate particles using a simple statistical theory called the continuous distribution of ellipsoids (CDE) theory. In this theory, the scattering properties of an ensemble are calculated. Recently a modified version of this theory was applied to measured spectra of scattering by kaolin particles. The particles were platelike, so the probability distribution of ellipsoidal shapes was chosen to reflect this. As with ammonium sulfate, the wavelength of measured peak backscattering is shifted longward of that predicted by Mie theory.

  12. Prevalence of refractive errors in Möbius sequence.

    PubMed

    Cronemberger, Monica Fialho; Polati, Mariza; Debert, Iara; Mendonça, Tomás Scalamandré; Souza-Dias, Carlos; Miller, Marilyn; Ventura, Liana Oliveira; Nakanami, Célia Regina; Goldchmit, Mauro

    2013-01-01

    To assess the prevalence of refractive errors in Möbius sequence. This study was carried out during the Annual Meeting of the Brazilian Möbius Society in November 2008. Forty-four patients diagnosed with the Möbius sequence were submitted to a comprehensive assessment, on the following specialties: ophthalmology, neurology, genetics, psychiatry, psychology and dentistry. Forty-three patients were cooperative and able to undertake the ophthalmological examination. Twenty-two (51.2 %) were male and 21 (48.8%) were female. The average age was 8.3 years (from 2 to 17 years). The visual acuity was evaluated using a retro-illuminated logMAR chart in cooperative patients. All children were submitted to exams on ocular motility, cyclopegic refraction, and fundus examination. From the total of 85 eyes, using the spherical equivalent, the major of the eyes (57.6%) were emmetropics (>-0.50 D and <+2.00 D). The prevalence of astigmatism greater than or equal to 0.75 D was 40%. The prevalence of refractive errors, by the spherical equivalent, was 42.4% in this studied group.

  13. Equivalent mechanical model of large-amplitude liquid sloshing under time-dependent lateral excitations in low-gravity conditions

    NASA Astrophysics Data System (ADS)

    Nan, Miao; Junfeng, Li; Tianshu, Wang

    2017-01-01

    Subjected to external lateral excitations, large-amplitude sloshing may take place in propellant tanks, especially for spacecraft in low-gravity conditions, such as landers in the process of hover and obstacle avoidance during lunar soft landing. Due to lateral force of the order of gravity in magnitude, the amplitude of liquid sloshing becomes too big for the traditional equivalent model to be accurate. Therefore, a new equivalent mechanical model, denominated the "composite model", that can address large-amplitude lateral sloshing in partially filled spherical tanks is established in this paper, with both translational and rotational excitations considered. The hypothesis of liquid equilibrium position following equivalent gravity is first proposed. By decomposing the large-amplitude motion of a liquid into bulk motion following the equivalent gravity and additional small-amplitude sloshing, a better simulation of large-amplitude liquid sloshing is presented. The effectiveness and accuracy of the model are verified by comparing the slosh forces and moments to results of the traditional model and CFD software.

  14. Differences in chemical doping matter: Superconductivity in Ti 1-xTa xSe 2 but not in Ti 1-xNb xSe 2

    DOE PAGES

    Luo, Huixia; Zhu, Yimei; Xie, Weiwei; ...

    2016-02-21

    We report that 1T-TiSe 2, an archetypical layered transition metal dichalcogenide, becomes superconducting when Ta is substituted for Ti but not when Nb is substituted for Ti. This is unexpected because Nb and Ta should be chemically equivalent electron donors. Superconductivity emerges near x = 0.02 for Ti 1–xTa xSe 2, while, for Ti 1–xNb xSe 2, no superconducting transitions are observed above 0.4 K. The equivalent chemical nature of the dopants is confirmed by X-ray photoelectron spectroscopy. ARPES and Raman scattering studies show similarities and differences between the two systems, but the fundamental reasons why the Nb and Tamore » dopants yield such different behavior are unknown. We present a comparison of the electronic phase diagrams of many electron-doped 1T-TiSe 2 systems, showing that they behave quite differently, which may have broad implications in the search for new superconductors. Here, we propose that superconducting Ti 0.8Ta 0.2Se 2 will be suitable for devices and other studies based on exfoliated crystal flakes.« less

  15. Testing Moderating Detection Systems with {sup 252}Cf-Based Reference Neutron Fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hertel, Nolan E.; Sweezy, Jeremy; Sauber, Jeremiah S.

    Calibration measurements were carried out on a probe designed to measure ambient dose equivalent in accordance with ICRP Pub 60 recommendations. It consists of a cylindrical {sup 3}He proportional counter surrounded by a 25-cm-diameter spherical polyethylene moderator. Its neutron response is optimized for dose rate measurements of neutrons between thermal energies and 20 MeV. The instrument was used to measure the dose rate in four separate neutron fields: unmoderated {sup 252}Cf, D{sub 2}O-moderated {sup 252}Cf, polyethylene-moderated {sup 252}Cf, and WEP neutron howitzer with {sup 252}Cf at its center. Dose equivalent measurements were performed at source-detector centerline distances from 50 tomore » 200 cm. The ratio of air-scatter- and room-return-corrected ambient dose equivalent rates to ambient dose equivalent rates calculated with the code MCNP are tabulated.« less

  16. Comparison of myopia control between toric and spherical periphery design orthokeratology in myopic children with moderate-to-high corneal astigmatism.

    PubMed

    Zhang, Yu; Chen, Yue-Guo

    2018-01-01

    To compare clinical results between toric and spherical periphery design orthokeratology (ortho-k) in myopic children with moderate-to-high corneal astigmatism. This retrospective study enrolled 62 eyes of 62 subjects using toric ortho-k lenses. These subjects were assigned to the toric group. Based on the one-to-one match principle (same age, proximate spherical equivalence and corneal astigmatism), 62 eyes of 62 subjects were enrolled and included in the spherical group. At one-year follow-up visit, visual acuity, corneal astigmatism, treatment zone decentration, axial elongation and adverse reaction were compared between these two groups. At the one-year visit, corneal astigmatism was significantly lower in the toric group (1.22±0.76 D) than in the spherical group (2.05±0.85 D) ( P =0.012). The mean magnitude of the treatment zone decentration was 0.62±0.42 mm in the toric group and 1.07±0.40 mm in the spherical group ( P =0.004). Axial elongation was significantly slower in the toric group (0.04±0.13 mm) than in the spherical group (0.09±0.13 mm) ( P =0.001). The one-year axial elongation was significantly correlated with initial age ( r =-0.487, P <0.001) and periphery design of ortho-k lens ( r =0.315, P <0.001). The incidence of corneal staining was lower in the toric group (8.1%) than in the spherical group (19.4%) ( P <0.001). Toric periphery design ortho-k lenses may provide lower corneal astigmatism, better centration, slower axial elongation and lower incidence of corneal staining in myopic children with moderate-to-high corneal astigmatism.

  17. Effect of Dangling Bond Spins on the Dark Exciton Recombination and Spin Polarization in CdSe Colloidal Nanostructures

    NASA Astrophysics Data System (ADS)

    Rodina, A. V.; Golovatenko, A. A.; Shornikova, E. V.; Yakovlev, D. R.; Efros, Al. L.

    2018-04-01

    We present theoretical aspects of the exchange interaction between the ground optically-forbidden "dark" exciton state and surface dangling bonds in colloidal CdSe spherical nanocrystals and nanoplatelets. The influence of the dangling bond spins on the radiative recombination and spin splitting of the dark exciton is shown. Processes of optically-driven and external magnetic field-driven formation of the dangling bond magnetic polaron (DBMP) are considered. Thermodynamic and dynamic polarization mechanisms of the DBMP formation within these two processes and corresponding critical temperatures are compared. Experimental manifestations of the DBMP formation in CdSe nanocrystals and nanoplatelets are discussed.

  18. [Three Years Follow-up Study after Refractive Small Incision Lenticule Extraction (SMILE) Using 500 kHz Femtosecond Laser in "Fast Mode"].

    PubMed

    Messerschmidt-Roth, A; Sekundo, W; Lazaridis, A; Schulze, S

    2017-01-01

    Background   The aim of this clinical trial was to check the results of laser built-in settings 3 years after ReLEx SMILE for moderate and high myopia in unselected "real life" patients. Patients and Methods   50 myopic eyes of 27 patients were called in for examination after 3 years. 25 of these eyes with a preoperative myopia under - 6D comprised the "moderate myopia subgroup". All surgeries were performed with the 500 kHz VisuMax® femtosecond laser (Carl Zeiss Meditec AG, Jena) in the "fast mode" setting. Results   The spherical equivalent (SE) of the entire group changed from - 6.18 D (± 1.91) prior to surgery to - 0.18 D (± 0.39) 3 years later. The preoperative SE in the moderate myopia subgroup changed from - 4.71 D (± 0.94) to - 0.04 D (± 0.23). 14 % of 50 eyes gained one line and 22 % lost one line of CDVA. The regression between month 3 and 36 was 0.07D for the entire group and 0.06 D for the moderate myopia subgroup. There were no late side effects. Primary undercorrection was predominantly seen in eyes over - 6 D. Conclusion   ReLEx SMILE shows remarkable stability over the entire range of myopias after 3 years, however primary undercorrection occurs predominantly in eyes of - 6.0 D, which necessitates nomogram adjustment. Georg Thieme Verlag KG Stuttgart · New York.

  19. Manual limbal markings versus iris-registration software for correction of myopic astigmatism by laser in situ keratomileusis.

    PubMed

    Shen, Elizabeth P; Chen, Wei-Li; Hu, Fung-Rong

    2010-03-01

    To compare the efficacy and safety of manual limbal markings and wavefront-guided treatment with iris-registration software in laser in situ keratomileusis (LASIK) for myopic astigmatism. National Taiwan University Hospital, Taipei, Taiwan. Eyes with myopic astigmatism had LASIK with a Technolas 217z laser. Eyes in the limbal-marking group had conventional LASIK (PlanoScan or Zyoptix tissue-saving algorithm) with manual cyclotorsional-error adjustments according to 2 limbal marks. Eyes in the iris-registration group had wavefront-guided ablation (Zyoptix) in which cyclotorsional errors were automatically detected and adjusted. Refraction, corneal topography, and visual acuity data were compared between groups. Vector analysis was by the Alpins method. The mean preoperative spherical equivalent (SE) was -6.64 diopters (D) +/- 1.99 (SD) in the limbal-marking group and -6.72 +/- 1.86 D in the iris-registration group (P = .92). At 6 months, the mean SE was -0.42 +/- 0.63 D and -0.47 +/- 0.62 D, respectively (P = .08). There was no statistically significant difference between groups in the astigmatism correction, success, or flattening index values using 6-month postoperative refractive data. The angle of error was within +/-10 degrees in 73% of eyes in the limbal-marking group and 75% of eyes in the iris-registration group. Manual limbal markings and iris-registration software were equally effective and safe in LASIK for myopic astigmatism, showing that checking cyclotorsion by manual limbal markings is a safe alternative when automated systems are not available. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  20. [Results of residual ametropia correction using CIRCLE technology after femtosecond laser SMILE surgery].

    PubMed

    Kostin, O A; Rebrikov, S V; Ovchinnikov, A I; Stepanov, A A; Takhchidi, Kh P

    to evaluate functional results of reoperation performed according to the CIRCLE technology and using the VisuMax femtosecond laser and MEL-80 excimer laser in cases of regression of the refractive effect after SMILE surgery. We studied a group of post-SMILE patients. In those, who showed regression of the refractive effect at 1 year, reoperation was performed according to the CIRCLE technology and using the VisuMax femtosecond laser. The corneal flap was separated from the stromal bed and turned aside. Excimer laser ablation of the stromal bed was performed with the MEL 80 machine. The corneal flap was then placed back and rinsed from both sides. Uncorrected (UCVA) and corrected (BCVA) visual acuity as well as spherical equivalent (SE) were estimated before reoperation, on day 1, and at 1 month. After reoperation, BCVA and UCVA improved. Patient refraction became close to emmetropia. Specifically, UCVA was 0.23±0.18 at baseline (i.e. 1 year after SMILE) and 0.93±0.11 after the CIRCLE procedure (p<0.05). The absolute value of SE was 1.86±1.15 D and 0±0 D before and after CIRCLE, respectively (p<0.05). BCVA change was not statistically significant - from 0.95±0.1 to 0.93±0.11 (p>0.05). Reoperation performed according to the CIRCLE technology and using the VisuMax femtosecond laser and MEL-80 excimer laser provides an increase in visual acuity in case of post-SMILE regression of the refractive effect.

  1. Refractive Status and Prevalence of Refractive Errors in Suburban School-age Children

    PubMed Central

    Pi, Lian-Hong; Chen, Lin; Liu, Qin; Ke, Ning; Fang, Jing; Zhang, Shu; Xiao, Jun; Ye, Wei-Jiang; Xiong, Yan; Shi, Hui; Yin, Zheng-Qin

    2010-01-01

    Objective: This study investigated the distribution pattern of refractive status and prevalence of refractive errors in school-age children in Western China to determine the possible environmental factors. Methods: A random sampling strategy in geographically defined clusters was used to identify children aged 6-15 years in Yongchuan, a socio-economically representative area in Western China. We carried out a door-to-door survey and actual eye examinations, including visual acuity measurements, stereopsis examination, anterior segment and eyeball movements, fundus examinations, and cycloplegic retinoscopy with 1% cyclopentolate. Results: A total of 3469 children living in 2552 households were selected, and 3070 were examined. The distributions of refractive status were positively-skewed for 6-8-year-olds, and negatively-skewed for 9-12 and 13-15-year-olds. The prevalence of hyperopia (≥+2.00 D spherical equivalent [SE]), myopia (≤-0.50 D SE), and astigmatism (≥1.00 diopter of cylinder [DC]) were 3.26%, 13.75%, and 3.75%, respectively. As children's ages increased, the prevalence rate of hyperopia decreased (P<0.001) and that of myopia increased significantly (P<0.001). Children in academically challenging schools had a higher risk of myopia (P<0.001) and astigmatism (≥1.00DC, P =0.04) than those in regular schools. Conclusion: The distribution of refractive status changes gradually from positively-skewed to negatively-skewed distributions as age increases, with 9-year-old being the critical age for the changes. Environmental factors and study intensity influence the occurrence and development of myopia. PMID:20975844

  2. Photorefractive keratectomy in young Asian aviators with low-moderate myopia.

    PubMed

    See, Brian; Tan, Marcus; Chia, Sin Eng; Gan, Wee Hoe; Low, Robin; Nah, Gerard

    2014-01-01

    The high prevalence of myopia among Asians led the Republic of Singapore Air Force (RSAF) to introduce photorefractive keratectomy (PRK) as a means of enlarging its pilot recruitment pool at the end of 2005. This study aims to address the efficacy and safety of PRK performed on young Asian patients with low-moderate myopia, as well as audit the RSAF's corneal refractive surgery (CRS) program. This is a retrospective case series of 149 eyes of 76 consecutive patients that underwent PRK as part of the RSAF CRS program over the 5-yr period from 1 January 2006 to 31 December 2010. The median patient age was 21 yr (range, 18-26 yr) and the mean preoperative spherical equivalent (SE) refraction was -3.39 - 1.19 D. Of the patients, 96.1% were men and all were of Asian origin. At the 12-mo follow-up, 98.5% of eyes had an uncorrected distance visual acuity (UDVA) of < or = 0.00 LogMAR, 100.0% of eyes had an SE refraction of within + 0.50 D of intended correction, and 2.300% of eyes had a loss of corrected distance visual acuity (CDVA) of 0.20 LogMAR. The cumulative incidence of retreatments was 6.7% and cumulative incidence of grade II or worse corneal haze requiring retreatment was 6.0%. Refractive stability was achieved at 3 mo postsurgery. The results of this study suggest that PRK performed within the context of a stringent and structured CRS program on young Asian eyes with low-moderate myopia is both efficacious and safe, with refractive stability achieved by 3 mo.

  3. Monte Carlo Simulations Comparing the Response of a Novel Hemispherical Tepc to Existing Spherical and Cylindrical Tepcs for Neutron Monitoring and Dosimetry.

    PubMed

    Broughton, David P; Waker, Anthony J

    2017-05-01

    Neutron dosimetry in reactor fields is currently mainly conducted with unwieldy flux monitors. Tissue Equivalent Proportional Counters (TEPCs) have been shown to have the potential to improve the accuracy of neutron dosimetry in these fields, and Multi-Element Tissue Equivalent Proportional Counters (METEPCs) could reduce the size of instrumentation required to do so. Complexity of current METEPC designs has inhibited their use beyond research. This work proposes a novel hemispherical counter with a wireless anode ball in place of the traditional anode wire as a possible solution for simplifying manufacturing. The hemispherical METEPC element was analyzed as a single TEPC to first demonstrate the potential of this new design by evaluating its performance relative to the reference spherical TEPC design and a single element from a cylindrical METEPC. Energy deposition simulations were conducted using the Monte Carlo code PHITS for both monoenergetic 2.5 MeV neutrons and the neutron energy spectrum of Cf-D2O moderated. In these neutron fields, the hemispherical counter appears to be a good alternative to the reference spherical geometry, performing slightly better than the cylindrical counter, which tends to underrespond to H*(10) for the lower neutron energies of the Cf-D2O moderated field. These computational results are promising, and if follow-up experimental work demonstrates the hemispherical counter works as anticipated, it will be ready to be incorporated into an METEPC design.

  4. Study of Theories about Myopia Progression (STAMP) Design and Baseline Data

    PubMed Central

    Berntsen, David A.; Mutti, Donald O.; Zadnik, Karla

    2011-01-01

    Purpose The Study of Theories about Myopia Progression (STAMP) is a two-year, double-masked, randomized clinical trial of myopic children 6 to 11 years old. STAMP will evaluate the one-year effect of progressive addition lenses (PALs) compared to single vision lenses (SVLs) on central refraction, peripheral refraction in four quadrants, and accommodative response and convergence. STAMP will also evaluate any changes one year after discontinuing PALs. Baseline characteristics of enrolled children are reported. Methods Eligible children had a high accommodative lag and either: (1) low myopia (less myopic than −2.25 D spherical equivalent) or (2) high myopia (more myopic that −2.25 D spherical equivalent) and esophoria at near. Children were randomly assigned to wear either PALs or SVLs for one year to determine the difference in myopia progression in the PAL group relative to the SVL group. All children will then wear SVLs for the second year to evaluate the permanence of any treatment effect. Complete ocular biometric data are collected at six-month intervals. Results Over 17 months, 192 children were screened, and 85 (44%) were eligible and enrolled. Of these 85 children, 44 (52%) were female, and 54 (64%) were esophoric at near. The mean age (± SD) was 9.8 ± 1.3 years. The right eye mean cycloplegic spherical equivalent refractive error was −1.95 ± 0.78 D. Horizontal relative peripheral hyperopia (30° nasal retina +0.56 ± 0.59 D; 30° temporal retina +0.61 ± 0.77 D) and vertical relative peripheral myopia (30° superior retina −0.36 ± 0.92 D; 20° inferior retina −0.48 ± 0.83 D) were found. Conclusions The baseline data for STAMP are reported. Asymmetry between vertical and horizontal meridian relative peripheral refraction was found. STAMP will utilize the ocular biometric changes associated with the PAL-treatment effect to attempt to elucidate the mechanism responsible for the treatment effect. PMID:20935586

  5. Linkage Analysis of Quantitative Refraction and Refractive Errors in the Beaver Dam Eye Study

    PubMed Central

    Duggal, Priya; Lee, Kristine E.; Cheng, Ching-Yu; Klein, Ronald; Bailey-Wilson, Joan E.; Klein, Barbara E. K.

    2011-01-01

    Purpose. Refraction, as measured by spherical equivalent, is the need for an external lens to focus images on the retina. While genetic factors play an important role in the development of refractive errors, few susceptibility genes have been identified. However, several regions of linkage have been reported for myopia (2q, 4q, 7q, 12q, 17q, 18p, 22q, and Xq) and for quantitative refraction (1p, 3q, 4q, 7p, 8p, and 11p). To replicate previously identified linkage peaks and to identify novel loci that influence quantitative refraction and refractive errors, linkage analysis of spherical equivalent, myopia, and hyperopia in the Beaver Dam Eye Study was performed. Methods. Nonparametric, sibling-pair, genome-wide linkage analyses of refraction (spherical equivalent adjusted for age, education, and nuclear sclerosis), myopia and hyperopia in 834 sibling pairs within 486 extended pedigrees were performed. Results. Suggestive evidence of linkage was found for hyperopia on chromosome 3, region q26 (empiric P = 5.34 × 10−4), a region that had shown significant genome-wide evidence of linkage to refraction and some evidence of linkage to hyperopia. In addition, the analysis replicated previously reported genome-wide significant linkages to 22q11 of adjusted refraction and myopia (empiric P = 4.43 × 10−3 and 1.48 × 10−3, respectively) and to 7p15 of refraction (empiric P = 9.43 × 10−4). Evidence was also found of linkage to refraction on 7q36 (empiric P = 2.32 × 10−3), a region previously linked to high myopia. Conclusions. The findings provide further evidence that genes controlling refractive errors are located on 3q26, 7p15, 7p36, and 22q11. PMID:21571680

  6. Refractive Errors in 3–6 Year-Old Chinese Children: A Very Low Prevalence of Myopia?

    PubMed Central

    Lin, Lixia; Li, Zhen; Zeng, Junwen; Yang, Zhikuan; Morgan, Ian G.

    2013-01-01

    Purpose To examine the prevalence of refractive errors in children aged 3–6 years in China. Methods Children were recruited for a trial of a home-based amblyopia screening kit in Guangzhou preschools, during which cycloplegic refractions were measured in both eyes of 2480 children. Cycloplegic refraction (from 3 to 4 drops of 1% cyclopentolate to ensure abolition of the light reflex) was measured by both autorefraction and retinoscopy. Refractive errors were defined as followed: myopia (at least −0.50 D in the worse eye), hyperopia (at least +2.00 D in the worse eye) and astigmatism (at least 1.50 D in the worse eye). Different definitions, as specified in the text, were also used to facilitate comparison with other studies. Results The mean spherical equivalent refractive error was at least +1.22 D for all ages and both genders. The prevalence of myopia for any definition at any age was at most 2.5%, and lower in most cases. In contrast, the prevalence of hyperopia was generally over 20%, and declined slightly with age. The prevalence of astigmatism was between 6% and 11%. There was very little change in refractive error with age over this age range. Conclusions Previous reports of less hyperopic mean spherical equivalent refractive error, and more myopia and less hyperopia in children of this age may be due to problems with achieving adequate cycloplegia in children with dark irises. Using up to 4 drops of 1% cyclopentolate may be necessary to accurately measure refractive error in paediatric studies of such children. Our results suggest that children from all ethnic groups may follow a similar pattern of early refractive development, with little myopia and a hyperopic mean spherical equivalent over +1.00 D up to the age of 5–6 yearsin most conditions. PMID:24205064

  7. Studies of intrastromal corneal ring segments for the correction of low to moderate myopic refractive errors.

    PubMed Central

    Schanzlin, D J

    1999-01-01

    PURPOSE: Intrastromal corneal ring segments (ICRS) were investigated for safety and reliability in the correction of low to moderate myopic refractive errors. METHODS: Initially, 74 patients with spherical equivalent refractive errors between -1.00 and -4.25 diopters (D) received the ICRS in 1 eye. After 6 months, 51 of these patients received the ICRS in the contralateral eye. The total number of eyes investigated was 125. The outcome measures were uncorrected and best-corrected visual acuity, predictability and stability of the refraction, refractive astigmatism, contrast sensitivity, and endothelial cell morphology. RESULTS: The 89 eyes with 12-month follow-up showed significant improvement with uncorrected visual acuities of 20/16 or better in 37%, 20/20 or better in 62%, and 20/40 or better in 97%. Cycloplegic refraction spherical equivalents showed that 68% of the eyes were within +/- 0.50 D and 90% within +/- 1.00 D of the intended correction. Refractive stability was present by 3 months after the surgery. Only 1 patients had a loss greater than 2 lines or 10 letters of best spectacle-corrected visual acuity, but the patient's acuity was 20/20. Refractive cylinder, contrast sensitivity, and endothelial cell morphology were not adversely affected. The ICRS was removed from the eyes of 6 patients. Three removals were prompted by glare and double images occurring at night; 3 were for nonmedical reasons. All patients returned to within +/- 1.00 D of their preoperative refractive spherical equivalent, and no patients lost more than 1 line of best corrected visual acuity by 3 months after ICRS removal. CONCLUSION: The ICRS safely and reliably corrects myopic refractive errors between -1.00 and -4.50 D. Images FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 6 FIGURE 7 FIGURE 8 FIGURE 9 FIGURE 10 FIGURE 11 FIGURE 12 PMID:10703146

  8. Heterogeneous nucleation on convex spherical substrate surfaces: A rigorous thermodynamic formulation of Fletcher's classical model and the new perspectives derived.

    PubMed

    Qian, Ma; Ma, Jie

    2009-06-07

    Fletcher's spherical substrate model [J. Chem. Phys. 29, 572 (1958)] is a basic model for understanding the heterogeneous nucleation phenomena in nature. However, a rigorous thermodynamic formulation of the model has been missing due to the significant complexities involved. This has not only left the classical model deficient but also likely obscured its other important features, which would otherwise have helped to better understand and control heterogeneous nucleation on spherical substrates. This work presents a rigorous thermodynamic formulation of Fletcher's model using a novel analytical approach and discusses the new perspectives derived. In particular, it is shown that the use of an intermediate variable, a selected geometrical angle or pseudocontact angle between the embryo and spherical substrate, revealed extraordinary similarities between the first derivatives of the free energy change with respect to embryo radius for nucleation on spherical and flat substrates. Enlightened by the discovery, it was found that there exists a local maximum in the difference between the equivalent contact angles for nucleation on spherical and flat substrates due to the existence of a local maximum in the difference between the shape factors for nucleation on spherical and flat substrate surfaces. This helps to understand the complexity of the heterogeneous nucleation phenomena in a practical system. Also, it was found that the unfavorable size effect occurs primarily when R<5r( *) (R: radius of substrate and r( *): critical embryo radius) and diminishes rapidly with increasing value of R/r( *) beyond R/r( *)=5. This finding provides a baseline for controlling the size effects in heterogeneous nucleation.

  9. Averaged ratio between complementary profiles for evaluating shape distortions of map projections and spherical hierarchical tessellations

    NASA Astrophysics Data System (ADS)

    Yan, Jin; Song, Xiao; Gong, Guanghong

    2016-02-01

    We describe a metric named averaged ratio between complementary profiles to represent the distortion of map projections, and the shape regularity of spherical cells derived from map projections or non-map-projection methods. The properties and statistical characteristics of our metric are investigated. Our metric (1) is a variable of numerical equivalence to both scale component and angular deformation component of Tissot indicatrix, and avoids the invalidation when using Tissot indicatrix and derived differential calculus for evaluating non-map-projection based tessellations where mathematical formulae do not exist (e.g., direct spherical subdivisions), (2) exhibits simplicity (neither differential nor integral calculus) and uniformity in the form of calculations, (3) requires low computational cost, while maintaining high correlation with the results of differential calculus, (4) is a quasi-invariant under rotations, and (5) reflects the distortions of map projections, distortion of spherical cells, and the associated distortions of texels. As an indicator of quantitative evaluation, we investigated typical spherical tessellation methods, some variants of tessellation methods, and map projections. The tessellation methods we evaluated are based on map projections or direct spherical subdivisions. The evaluation involves commonly used Platonic polyhedrons, Catalan polyhedrons, etc. Quantitative analyses based on our metric of shape regularity and an essential metric of area uniformity implied that (1) Uniform Spherical Grids and its variant show good qualities in both area uniformity and shape regularity, and (2) Crusta, Unicube map, and a variant of Unicube map exhibit fairly acceptable degrees of area uniformity and shape regularity.

  10. Colloidal Spherical Quantum Wells with Near-Unity Photoluminescence Quantum Yield and Suppressed Blinking.

    PubMed

    Jeong, Byeong Guk; Park, Young-Shin; Chang, Jun Hyuk; Cho, Ikjun; Kim, Jai Kyeong; Kim, Heesuk; Char, Kookheon; Cho, Jinhan; Klimov, Victor I; Park, Philip; Lee, Doh C; Bae, Wan Ki

    2016-10-02

    Thick inorganic shell endows colloidal nanocrystals (NCs) with enhanced photochemical stability and suppression of photoluminescence intermittency (also known as blinking). However, the progress of using thick-shell heterostructure NCs in applications has been limited, due to low photoluminescence quantum yield (PL QY  60%) at room temperature. Here, we demonstrate thick-shell NCs with CdS/CdSe/CdS seed/spherical quantum well/shell (SQW) geometry that exhibit near-unity PL QY at room temperature and suppression of blinking. In SQW NCs, the lattice mismatch is diminished between the emissive CdSe layer and the surrounding CdS layers as a result of coherent strain, which suppresses the formation of misfit defects and consequently permits ~ 100% PL QY for SQW NCs with thick CdS shell (≥ 5 nm). High PL QY of thick-shell SQW NCs are preserved even in concentrated dispersion and in film under thermal stress, which makes them promising candidates for applications in solid-state lightings and luminescent solar concentrators.

  11. Outcomes of presbyopia-correcting intraocular lenses after laser in situ keratomileusis.

    PubMed

    Chow, Sharon S W; Chan, Tommy C Y; Ng, Alex L K; Kwok, Alvin K H

    2018-03-28

    Laser in situ keratomileusis (LASIK) is the most common refractive surgery in young patients, which aims at providing a clear distance vision without the use of spectacles. With time, these patients develop symptomatic cataract, which affects activities of daily living, and to improve visual acuity, intraocular lens (IOL) implantation can be considered. In post-myopic LASIK patients, to allow continuation of spectacle independence, the implantation of presbyopia-correcting IOLs is a suitable option. The purpose of this retrospective case series is to report the visual outcome and quality in post-myopic LASIK eyes after the implantation of AT LISA tri839MP IOL. Twenty eyes of 13 patients with history of myopic LASIK within 20 years underwent phacoemulsification by one single surgeon. All eyes were implanted with AT LISA tri839PMP IOL, and their outcomes were evaluated at 6 months postoperation. The mean postoperative uncorrected distance visual acuity (VA) is 0.28 ± 0.29, while the corrected distance VA is 0.06 ± 0.14. The mean postoperative uncorrected near VA is 0.02 ± 0.05, while the corrected near VA is 0.01 ± 0.02. The mean postoperative manifest refraction spherical equivalent (SE) is - 0.92 ± 0.76D. There is a statistically significant difference between the preoperative and postoperative refraction (p = 0.02), which shows a postoperative myopic shift. There is also a statistically significant difference between the mean targeted SE and postoperative manifest refraction SE (p = 0.00). Only one out of 20 eyes (5%) reported halo and glare symptoms. Ten out of 20 eyes (50%) are able to achieve spectacles independence. In conclusion, in post-myopic LASIK eyes, AT LISA tri839MP provides a good visual outcome at both near and distance, but is more predictable at near than at distance. There is a myopic shift in the postoperative SE. Visual quality is satisfactory and has not been exacerbated. Most patients can remain to be spectacles free at all distances.

  12. Refractive errors in a Brazilian population: age and sex distribution.

    PubMed

    Ferraz, Fabio H; Corrente, José E; Opromolla, Paula; Padovani, Carlos Roberto; Schellini, Silvana A

    2015-01-01

    To determine the prevalence of refractive errors and their distribution according to age and sex in a Brazilian population. This population-based cross-sectional study involved 7654 Brazilian inhabitants of nine municipalities of Sao Paulo State, Brazil, between March 2004 and July 2005. Participants aged >1 year were selected using a random, stratified, household cluster sampling technique, excluding individuals with previous refractive or cataract surgery. Myopia was defined as spherical equivalent (SE) ≤-0.5D, high myopia as SE ≤-3.0D, hyperopia as SE ≥+0.5D, high hyperopia as SE ≥+3D, astigmatism as ≤-0.5DC and anisometropia as ≥1.0D difference between eyes. Age, sex, complaints and a comprehensive eye examination including cycloplegic refraction test were collected and analysed using descriptive analysis, univariate and multivariate methods. The prevalence of astigmatism was 59.7%, hyperopia 33.8% and myopia was 25.3%. Astigmatism had a progressive increase with age. With-the-rule (WTR) axes of astigmatism were more frequently observed in the young participants and the against-the-rule (ATR) axes were more frequent in the older subjects. The onset of myopia occurred more frequently between the 2nd and 3rd decades of life. Anisometropia showed a prevalence of 13.2% (95% CI 12.4-13.9; p < 0.001). There was an association between age and all types of refractive error and hyperopia was also associated with sex. Hyperopia was associated with WTR axes (odds ratio 0.73; 95% CI: 0.6-0.8; p < 0.001) and myopia with ATR axes (odds ratio 0.66; 95% CI: 0.6-0.8; p < 0.001). Astigmatism was the most prevalent refractive error in a Brazilian population. There was a strong relationship between age and all refractive errors and between hyperopia and sex. WTR astigmatism was more frequently associated with hyperopia and ATR astigmatism with myopia. The vast majority of participants had low-grade refractive error, which favours planning aimed at correction of refractive error in the population. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.

  13. Visual outcomes after spectacles treatment in children with bilateral high refractive amblyopia.

    PubMed

    Lin, Pei-Wen; Chang, Hsueh-Wen; Lai, Ing-Chou; Teng, Mei-Ching

    2016-11-01

    The aim was to investigate the visual outcomes of treatment with spectacles for bilateral high refractive amblyopia in children three to eight years of age. Children with previously untreated bilateral refractive amblyopia were enrolled. Bilateral high refractive amblyopia was defined as visual acuity (VA) being worse than 6/9 in both eyes in the presence of 5.00 D or more of hyperopia, 5.00 D or more of myopia and 2.00 D or more of astigmatism. Full myopic and astigmatic refractive errors were corrected, and the hyperopic refractive errors were corrected within 1.00 D of the full correction. All children received visual assessments at four-weekly intervals. VA, Worth four-dot test and Randot preschool stereotest were assessed at baseline and every four weeks for two years. Twenty-eight children with previously untreated bilateral high refractive amblyopia were enrolled. The mean VA at baseline was 0.39 ± 0.24 logMAR and it significantly improved to 0.21, 0.14, 0.11, 0.05 and 0.0 logMAR at four, eight, 12, 24 weeks and 18 months, respectively (all p = 0.001). The mean stereoacuity (SA) was 1,143 ± 617 arcsec at baseline and it significantly improved to 701, 532, 429, 211 and 98 arcsec at four, eight, 12, 24 weeks and 18 months, respectively (all p = 0.001). The time interval for VA achieving 6/6 was significantly shorter in the eyes of low spherical equivalent (SE) (-2.00 D < SE < +2.00 D) than in those of high SE (SE > +2.00 D) (3.33 ± 2.75 months versus 8.11 ± 4.56 months, p = 0.0005). All subjects had normal fusion on Worth four-dot test at baseline and all follow-up visits. Refractive correction with good spectacles compliance improves VA and SA in young children with bilateral high refractive amblyopia. Patients with greater amounts of refractive error will achieve resolution of amblyopia with a longer time. © 2016 Optometry Australia.

  14. Equivalent source modeling of the main field using MAGSAT data

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The software was considerably enhanced to accommodate a more comprehensive examination of data available for field modeling using the equivalent sources method by (1) implementing a dynamic core allocation capability into the software system for the automatic dimensioning of the normal matrix; (2) implementing a time dependent model for the dipoles; (3) incorporating the capability to input specialized data formats in a fashion similar to models in spherical harmonics; and (4) implementing the optional ability to simultaneously estimate observatory anomaly biases where annual means data is utilized. The time dependence capability was demonstrated by estimating a component model of 21 deg resolution using the 14 day MAGSAT data set of Goddard's MGST (12/80). The equivalent source model reproduced both the constant and the secular variation found in MGST (12/80).

  15. Evaluation of retinal nerve fiber layer thickness parameters in myopic population using scanning laser polarimetry (GDxVCC).

    PubMed

    Dada, Tanuj; Aggarwal, A; Bali, S J; Sharma, A; Shah, B M; Angmo, D; Panda, A

    2013-01-01

    Myopia presents a significant challenge to the ophthalmologist as myopic discs are often large, tilted, with deep cups and have a thinner neuroretinal rim all of which may mimic glaucomatous optic nerve head changes causing an error in diagnosis. To evaluate the retinal fiber layer (RNFL) thickness in low, moderate and high myopia using scanning laser polarimetry with variable corneal compensation (GDxVCC). One hundred eyes of 100 emmetropes, 30 eyes of low myopes (0 to - 4 D spherical equivalent(SE), 45 eyes with moderate myopia (- 4 to - 8D SE), and 30 eyes with high myopia (- 8 to - 15D SE) were subjected to retinal nerve fiber layer assessment using the scanning laser polarimetry (GDxVCC) in all subjects using the standard protocol. Subjects with IOP > 21 mm Hg, optic nerve head or visual field changes suggestive of glaucoma were excluded from the study. The major outcome parameters were temporal-superior-nasal-inferiortemporal (TSNIT) average, the superior and inferior average and the nerve fibre indicator (NFI). The TSNIT average (p = 0.009), superior (p = 0.001) and inferior average (p = 0.008) were significantly lower; the NFI was higher (P less than 0.001) in moderate myopes as compared to that in emmetropes. In high myopia the RNFL showed supranormal values; the TSNIT average, superior and inferior average was significantly higher(p less than 0.001) as compared to that in emmetropes. The RNFL measurements on scanning laser polarimetry are affected by the myopic refractive error. Moderate myopes show a significant thinning of the RNFL. In high myopia due to peripapillary chorioretinal atrophy and contribution of scleral birefringence, the RNFL values are abnormally high. These findings need to be taken into account while assessing and monitoring glaucoma damage in moderate to high myopes on GDxVCC. © NEPjOPH.

  16. Effect of uncorrection versus full correction on myopia progression in 12-year-old children.

    PubMed

    Sun, Yun-Yun; Li, Shi-Ming; Li, Si-Yuan; Kang, Meng-Tian; Liu, Luo-Ru; Meng, Bo; Zhang, Feng-Ju; Millodot, Michel; Wang, Ningli

    2017-01-01

    To investigate the effects of no correction versus full correction on myopia progression in Chinese children over a period of 2 years. Myopia was defined as cycloplegic spherical equivalent (SE) of ≤ -0.50 D. Uncorrection was defined as no spectacles worn, and full correction was defined as when the value of SE subtracted from the dioptric power of the child's current spectacles was less than 0.5 D. Ocular examinations included visual acuity, cycloplegic autorefraction, axial length and vertometer measurements. Questionnaires were completed by parents on behalf of the children. A total of 121 myopic children, with a median age of 12.7 years, were screened from the Anyang Childhood Eye Study, with 65 in the uncorrected group and 56 in the full correction group. At 2-year follow-up, children with no correction had slower myopia progression (-0.75 ± 0.49 D vs. -1.04 ± 0.49 D, P < 0.01) and less axial elongation (0.45 ± 0.18 mm vs. 0.53 ± 0.17 mm, P = 0.02) than children with full correction. In multivariate modeling, adjusting for baseline SE or axial length, age, gender, height, number of myopic parents, age at myopia onset, and time spent in near work and outdoors, children with no correction still had slower myopia progression (-0.76 ± 0.07 vs. -1.03 ± 0.08 D, P < 0.01) and less axial elongation (0.47 ± 0.03 mm vs. 0.51 ± 0.03 mm, P < 0.01). Myopia progression decreased significantly with an increasing amount of undercorrection in all children (r = 0.22, b = 0.16, P = 0.01). Our findings suggest that myopic defocus slows the progression of myopia in already myopic children, supporting previous findings from animal studies.

  17. Cycloplegic Refraction in Hyperopic Children: Effectiveness of a 0.5% Tropicamide and 0.5% Phenylephrine Addition to 1% Cyclopentolate Regimen.

    PubMed

    Yoo, Seul Gi; Cho, Myung Jin; Kim, Ungsoo Samuel; Baek, Seung Hee

    2017-06-01

    To evaluate the effectiveness of a cycloplegic regimen using 0.5% tropicamide and 0.5% phenylephrine (Tropherine, Hanmi Pharm), in addition to 1% cyclopentolate, in hyperopic children. The medical records of hyperopic patients below the age of 14 years who had undergone cycloplegic retinoscopy were retrospectively reviewed. Cycloplegic refractions were performed using one of two cycloplegic regimens. Regimen 1 was a Tropherine-added regimen comprising the administration of one drop of 1% cyclopentolate followed by two to three drops of Tropherine added at 15-minute intervals. Regimen 2 was a cyclopentolate-only regimen comprising the administration of three to four drops of 1% cyclopentolate at 15-minute intervals. The mean difference between noncycloplegic and cycloplegic refraction was compared between the two regimens. A total of 308 eyes of 308 hyperopic children were included. The mean difference (±standard deviation) in the spherical equivalent (SE) between cycloplegic and noncycloplegic refraction was significantly larger in regimen 2 than in regimen 1, with values of +1.70 ± 1.03 diopters (D) and +1.25 ± 0.89 D, respectively (p=0.001). The SE change after cycloplegia was significantly different between the two regimens only in patients aged 5 years or younger (p=0.001), particularly in those with high hyperopia with an SE ≥5 D (p=0.005) or fully accommodative esotropia (p=0.009). There was no significant difference between the two regimens in patients older than 5 years, regardless of the presence of high hyperopia or fully accommodative esotropia. The Tropherine-added regimen exerted a weaker cycloplegic effect than the cyclopentolate-only regimen, particularly in children under the age of 5 years with high hyperopia or fully accommodative esotropia. However, the difference in refraction between the two regimens was small. A Tropherine-added regimen can be effective in hyperopic children, with less associated discomfort than the instillation of cyclopentolate. © 2017 The Korean Ophthalmological Society

  18. Cycloplegic Refraction in Hyperopic Children: Effectiveness of a 0.5% Tropicamide and 0.5% Phenylephrine Addition to 1% Cyclopentolate Regimen

    PubMed Central

    Yoo, Seul Gi; Cho, Myung Jin; Kim, Ungsoo Samuel

    2017-01-01

    Purpose To evaluate the effectiveness of a cycloplegic regimen using 0.5% tropicamide and 0.5% phenylephrine (Tropherine, Hanmi Pharm), in addition to 1% cyclopentolate, in hyperopic children. Methods The medical records of hyperopic patients below the age of 14 years who had undergone cycloplegic retinoscopy were retrospectively reviewed. Cycloplegic refractions were performed using one of two cycloplegic regimens. Regimen 1 was a Tropherine-added regimen comprising the administration of one drop of 1% cyclopentolate followed by two to three drops of Tropherine added at 15-minute intervals. Regimen 2 was a cyclopentolate-only regimen comprising the administration of three to four drops of 1% cyclopentolate at 15-minute intervals. The mean difference between noncycloplegic and cycloplegic refraction was compared between the two regimens. Results A total of 308 eyes of 308 hyperopic children were included. The mean difference (±standard deviation) in the spherical equivalent (SE) between cycloplegic and noncycloplegic refraction was significantly larger in regimen 2 than in regimen 1, with values of +1.70 ± 1.03 diopters (D) and +1.25 ± 0.89 D, respectively (p=0.001). The SE change after cycloplegia was significantly different between the two regimens only in patients aged 5 years or younger (p=0.001), particularly in those with high hyperopia with an SE ≥5 D (p=0.005) or fully accommodative esotropia (p=0.009). There was no significant difference between the two regimens in patients older than 5 years, regardless of the presence of high hyperopia or fully accommodative esotropia. Conclusions The Tropherine-added regimen exerted a weaker cycloplegic effect than the cyclopentolate-only regimen, particularly in children under the age of 5 years with high hyperopia or fully accommodative esotropia. However, the difference in refraction between the two regimens was small. A Tropherine-added regimen can be effective in hyperopic children, with less associated discomfort than the instillation of cyclopentolate. PMID:28471102

  19. Development of Refractive Errors-What Can We Learn From Inherited Retinal Dystrophies?

    PubMed

    Hendriks, Michelle; Verhoeven, Virginie J M; Buitendijk, Gabriëlle H S; Polling, Jan Roelof; Meester-Smoor, Magda A; Hofman, Albert; Kamermans, Maarten; Ingeborgh van den Born, L; Klaver, Caroline C W

    2017-10-01

    It is unknown which retinal cells are involved in the retina-to-sclera signaling cascade causing myopia. As inherited retinal dystrophies (IRD) are characterized by dysfunction of a single retinal cell type and have a high risk of refractive errors, a study investigating the affected cell type, causal gene, and refractive error in IRDs may provide insight herein. Case-control study. Study Population: Total of 302 patients with IRD from 2 ophthalmogenetic centers in the Netherlands. Reference Population: Population-based Rotterdam Study-III and Erasmus Rucphen Family Study (N = 5550). Distributions and mean spherical equivalent (SE) were calculated for main affected cell type and causal gene; and risks of myopia and hyperopia were evaluated using logistic regression. Bipolar cell-related dystrophies were associated with the highest risk of SE high myopia 239.7; odds ratio (OR) mild hyperopia 263.2, both P < .0001; SE -6.86 diopters (D) (standard deviation [SD] 6.38), followed by cone-dominated dystrophies (OR high myopia 19.5, P < .0001; OR high hyperopia 10.7, P = .033; SE -3.10 D [SD 4.49]); rod dominated dystrophies (OR high myopia 10.1, P < .0001; OR high hyperopia 9.7, P = .001; SE -2.27 D [SD 4.65]), and retinal pigment epithelium (RPE)-related dystrophies (OR low myopia 2.7; P = .001; OR high hyperopia 5.8; P = .025; SE -0.10 D [SD 3.09]). Mutations in RPGR (SE -7.63 D [SD 3.31]) and CACNA1F (SE -5.33 D [SD 3.10]) coincided with the highest degree of myopia and in CABP4 (SE 4.81 D [SD 0.35]) with the highest degree of hyperopia. Refractive errors, in particular myopia, are common in IRD. The bipolar synapse and the inner and outer segments of the photoreceptor may serve as critical sites for myopia development. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Interface healing and its correlation with visual recovery and quality of vision following small incision lenticule extraction

    PubMed Central

    Ganesh, Sri; Brar, Sheetal; Pandey, Rahul; Pawar, Archana

    2018-01-01

    Purpose: To study the time course of interface healing and its correlation with visual acuity, modulation transfer function (MTF), and aberrations after myopic small-incision lenticule extraction (SMILE) correction. Methods: Seventy-eight eyes of 78 patients (1 eye per patient) with a mean age of 25.7 years and mean spherical equivalent (SE) of −3.74D, undergoing bilateral SMILE procedure, were included in this study. On postoperative day 1, 2 weeks, and 3 months, dilated retroillumination photographs were taken and morphology of corneal interface was graded by comparing them with 5 standard templates representing 5 grades of interface roughness (IRG): IRG – 0 (clear), IRG – 1 (mild), IRG – 2 (moderate), IRG – 3 (severe), and IRG – 4 (severe IRG with Bowman's folds in visual axis). Pearson's correlations were computed to study correlation associations, and Wilcoxon signed-rank test was used for intragroup comparison of means. P ≤ 0.05 was considered statistically significant. Results: At 3 months, 90.70% eyes were Grade 0 while 9.30% eyes still had Grade 2 interface granularity. Mean IRG significantly improved from 2.47 ± 0.57 at day 1 to 0.62 ± 0.53 at 3 months (P = 0.00). At day 1, pre-SE showed a significant positive correlation with IRG; however, mean postoperative corrected distant visual acuity (CDVA, in decimal), corneal Strehl ratio (SR), and MTF showed weak but significant negative correlation with IRG (r2 = 0.28 for SE, −0.052 for CDVA, −0.017 for SR, and −0.39 for MTF, respectively, P < 0.05 for all correlations). At 2 weeks and 3 months, corneal MTF continued to show a significant negative correlation, whereas other parameters did not show any correlation with IRG. Conclusion: Visual quality and corneal MTF may be significantly affected by the IRG in the immediate postoperative period after SMILE and may take 3 months or more for complete recovery. PMID:29380760

  1. Hyperopic laser in situ keratomileusis: comparison of femtosecond laser and mechanical microkeratome flap creation.

    PubMed

    Antonios, Rafic; Arba Mosquera, Samuel; Awwad, Shady T

    2015-08-01

    To evaluate and compare the refractive predictability and stability of laser in situ keratomileusis (LASIK) flap creation performed with a femtosecond laser and with a mechanical microkeratome to correct mild to moderate hyperopia. American University of Beirut Medical Center, Beirut, Lebanon. Retrospective case series. Patients who had hyperopic LASIK treatment using the Amaris excimer laser were included. Eyes in which the LDV femtosecond laser was used for flap creation were compared with eyes in which the Moria M2 microkeratome was used. The microkeratome group comprised 53 eyes and the femtosecond laser group, 72 eyes. Baseline characteristics were similar between groups (P > .05). The mean spherical equivalent (SE) deviation from target 1 week postoperatively was -0.08 diopter (D) ± 0.58 (SD) in the femtosecond laser group and -0.06 ± 0.87 D in the microkeratome group (P = .92). Thereafter, the mean SE deviation from target increased gradually and by 6 months postoperatively was +0.30 ± 0.50 D and +0.70 ± 0.71 D, respectively (P = .001). The correlation between the achieved and the attempted SE refraction was better in the femtosecond laser group (R(2) = 0.806) than the microkeratome group (R(2) = 0.671). Using the same nomogram, the short-term refractive outcomes of hyperopic LASIK with flap creation performed with the femtosecond laser were comparable to those for the microkeratome; however, the femtosecond group showed significantly better stability over the 6-month follow-up and better predictability, as reflected by a lower standard deviation and stronger Pearson correlation. Dr. Arba Mosquera is an employee of Schwind eye-tech-solutions GmbH and Co. KG. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  2. The effects of mild-to-severe retinopathy of prematurity on the development of refractive errors and strabismus.

    PubMed

    Gursoy, Huseyin; Basmak, Hikmet; Bilgin, Burak; Erol, Nazmiye; Colak, Ertugrul

    2014-06-01

    To investigate the effects of mild-to-severe retinopathy of prematurity (ROP) on refractive state and the incidence of strabismus. Infants born ≤32 weeks of gestation were prospectively evaluated. Inclusion criteria were a follow-up of at least 6 months and at least stage 1 ROP. Group 1 included stage 1 ROP cases. Cases with stage 2 or 3 ROP without indication for treatment formed the second group. Group 3 included cases who received treatment for ROP. Logistic regression, adjusted for birth weight and gestational age, and multiple comparison tests were used to compare outcomes among groups. The mean follow-up time was 20.9 ± 6.6 months. In the first (n = 21), second (n = 22), and third groups (n = 23), the right spherical equivalents (SE) were 1.17 ± 1.33, -0.18 ± 3.09, and -1.08 ± 4.05 diopters, and the left SEs were 1.23 ± 1.34, -0.09 ± 3.24, and -1.46 ± 4.02 diopters, respectively (p = 0.026 for right SE and 0.008 for left SE). The incidences of anisometropia were 3/21, 4/22, and 11/23 in the first, second, and third groups, respectively (adjusted odds ratios [aOR] for group 3 vs 1 = 5.39, aOR for group 3 vs 2 = 4.06). Strabismus developed in 7/21, 6/22, and 10/23 in groups one, two, and three, respectively (aOR for group 3 vs 1 = 2.06, aOR for group 3 vs 2 = 2.27). Eighteen of these were esotropias. Refractive errors and strabismus were associated with mild-to-severe ROP. Esotropia was the most frequent type of strabismus.

  3. Prevalence of refractive errors in a Brazilian population: the Botucatu eye study.

    PubMed

    Schellini, Silvana Artioli; Durkin, Shane R; Hoyama, Erika; Hirai, Flavio; Cordeiro, Ricardo; Casson, Robert J; Selva, Dinesh; Padovani, Carlos Roberto

    2009-01-01

    To determine the prevalence and demographic associations of refractive error in Botucatu, Brazil. A population-based, cross-sectional prevalence study was conducted, which involved random, household cluster sampling of an urban Brazilian population in Botucatu. There were 3000 individuals aged 1 to 91 years (mean 38.3) who were eligible to participate in the study. Refractive error measurements were obtained by objective refraction. Objective refractive error examinations were performed on 2454 residents within this sample (81.8% of eligible participants). The mean age was 38 years (standard deviation (SD) 20.8 years, Range 1 to 91) and females comprised 57.5% of the study population. Myopia (spherical equivalent (SE) < -0.5 dropters (D)) was most prevalent among those aged 30-39 years (29.7%; 95% confidence interval (CI) 24.8-35.1) and least prevalent among children under 10 years (3.8%; 95% confidence interval (CI) 1.6-7.3). Conversely hypermetropia (SE > 0.5D) was most prevalent among participants under 10 years (86.9%; 95% CI 81.6-91.1) and least prevalent in the fourth decade (32.5%; 95% CI 28.2-37.0). Participants aged 70 years or older bore the largest burden of astigmatism (cylinder at least -0.5D) and anisometropia (difference in SE of > 0.5D) with a prevalence of 71.7% (95% CI 64.8-78.0) 55.0% (95% CI 47.6-62.2) respectively. Myopia and hypermetropia were significantly associated with age in a bimodal manner (P < 0.001), whereas anisometropia and astigmatism increased in line with age (P < 0.001). Multivariate modeling confirmed age-related risk factors for refractive error and revealed several gender, occupation and ethnic-related risk factors. These results represent previously unreported data on refractive error within this Brazilian population. They signal a need to continue to screen for refractive error within this population and to ensure that people have adequate access to optical correction.

  4. Comparison of refractive errors and factors associated with spectacle use in a rural and urban South Indian population

    PubMed Central

    Prema, Raju; Sathyamangalam Ve, Ramesh; Hemamalini, Arvind; Baskaran, Mani; Kumaramanickavel, Govindaswamy; Catherine, McCarty; Vijaya, Lingam

    2008-01-01

    Purpose: To compare the prevalence of refractive errors and factors associated with spectacle use in a rural and urban south Indian population. Materials and Methods: Four thousand eight hundred subjects (age >39 years) each from rural and urban Tamil Nadu were enumerated for a population-based study. All participants underwent a complete ophthalmic evaluation including best-corrected visual acuity (BCVA), objective and subjective refraction. Out of 3924 rural responders 63.91% and out of 3850 urban responders 81.64% were phakic in the right eye with BCVA of 20/40 or better and were included in the study. Association of spectacle use and refractive errors with different parameters were analysed using logistic regression. Statistical Analysis: Chi square, t test, Chi square for trend and Pearson′s correlation coefficient were used for analysis. Results: Spectacle use was significantly higher and positively associated with literacy and employment in the urban population. The age and gender-adjusted prevalence of emmetropia, myopia of spherical equivalent (SE) ≤-0.50 diopter sphere (DS), high myopia (SE ≤-5.00DS), hyperopia (SE >0.50DS) and astigmatism ≤ 0.50 diopter cylinder (DC) were 46.8%, 31.0%, 4.3%, 17.9% and 60.4% respectively in the rural population and 29.0%, 17.6%, 1.5%, 51.9%, 59.1% respectively in the urban population. The prevalence of emmetropia decreased with age (p < 0.001); prevalence of myopia and high myopia increased with age (p = 0.001) and were associated with nuclear sclerosis (p = 0.001) in both populations. Hyperopia was commoner among women than men (p = 0.001); was positively associated with diabetes mellitus (p = 0.008) in the rural population and negatively with nuclear sclerosis (p = 0.001) in both populations. Conclusion: Spectacle use was found to be significantly lower in the rural population. The pattern of refractive errors was significantly different between both populations. PMID:18292625

  5. Interface healing and its correlation with visual recovery and quality of vision following small incision lenticule extraction.

    PubMed

    Ganesh, Sri; Brar, Sheetal; Pandey, Rahul; Pawar, Archana

    2018-02-01

    To study the time course of interface healing and its correlation with visual acuity, modulation transfer function (MTF), and aberrations after myopic small-incision lenticule extraction (SMILE) correction. Seventy-eight eyes of 78 patients (1 eye per patient) with a mean age of 25.7 years and mean spherical equivalent (SE) of -3.74D, undergoing bilateral SMILE procedure, were included in this study. On postoperative day 1, 2 weeks, and 3 months, dilated retroillumination photographs were taken and morphology of corneal interface was graded by comparing them with 5 standard templates representing 5 grades of interface roughness (IRG): IRG - 0 (clear), IRG - 1 (mild), IRG - 2 (moderate), IRG - 3 (severe), and IRG - 4 (severe IRG with Bowman's folds in visual axis). Pearson's correlations were computed to study correlation associations, and Wilcoxon signed-rank test was used for intragroup comparison of means. P ≤ 0.05 was considered statistically significant. At 3 months, 90.70% eyes were Grade 0 while 9.30% eyes still had Grade 2 interface granularity. Mean IRG significantly improved from 2.47 ± 0.57 at day 1 to 0.62 ± 0.53 at 3 months (P = 0.00). At day 1, pre-SE showed a significant positive correlation with IRG; however, mean postoperative corrected distant visual acuity (CDVA, in decimal), corneal Strehl ratio (SR), and MTF showed weak but significant negative correlation with IRG (r2 = 0.28 for SE, -0.052 for CDVA, -0.017 for SR, and -0.39 for MTF, respectively, P < 0.05 for all correlations). At 2 weeks and 3 months, corneal MTF continued to show a significant negative correlation, whereas other parameters did not show any correlation with IRG. Visual quality and corneal MTF may be significantly affected by the IRG in the immediate postoperative period after SMILE and may take 3 months or more for complete recovery.

  6. Outcomes of LASIK for Myopia or Myopic Astigmatism Correction with the FS200 Femtosecond Laser and EX500 Excimer Laser Platform

    PubMed Central

    Niparugs, Muanploy; Tananuvat, Napaporn; Chaidaroon, Winai; Tangmonkongvoragul, Chulaluck; Ausayakhun, Somsanguan

    2018-01-01

    Purpose: To evaluate the efficacy, predictability, stability and safety of laser in situ keratomileusis (LASIK) using the FS200 femtosecond laser and EX500 excimer laser platform. Methods: The outcomes of 254 eyes of 129 consecutive patients with myopia or myopic astigmatism who underwent full correction femtosecond laser-assisted LASIK at CMU LASIK Center were assessed. Pre-operative and post-operative parameters including manifest refraction, Uncorrected Distance Visual Acuity (UDVA), Best Corrected Distance Visual Acuity (BDVA), corneal topography and tomography were analyzed. The results between low to moderate myopia and high myopia were compared up to 12 months. Results: Mean pre-operative Spherical Equivalent (SE) was -5.15±2.41 Diopters (D) (range -0.50 to -11.50 D) and -0.13±0.28 D, -0.13±0.27 D, -0.13±0.28 D and -0.14±0.30 D at 1, 3, 6, and 12 months, post-operatively. At 12 months, the propor¬tion of eyes achieving UDVA ≥ 20/20 was 90.0% and ≥20/40 was 98.8%. The proportion of eyes achieving post-operative mean SE ±0.5 D, and ±1 D was 91.3%, and 98.5%. No eyes lost more than two lines of BDVA. The low to moderate myopic group had a statistically significant better UDVA at one (p=0.017) and three months (p=0.014) but no difference at six (p=0.061) and 12 months (p=0.091). The mean post-operative SE was better in low to moderate myopic group at every follow-up visit (p=0.001, 0.007, <0.001 and <0.001). Conclusion: One-year clinical results of LASIK with the FS200 femtosecond laser and EX500 excimer laser showed high efficacy, predictability, stability and safety. PMID:29872485

  7. Equal-Curvature X-ray Telescope Designs for Constellation-X Mission

    NASA Technical Reports Server (NTRS)

    Saha, Timo T.; Content, David A.; Zhang, William W.

    2003-01-01

    We study grazing incidence Equal-Curvature telescope designs for the Constellation-X mission. These telescopes have nearly spherical axial surfaces. The telescopes are designed so that the axial curvature is the same on the primary and secondary. The optical performance of these telescopes is for all practical purposes identical to the equivalent Wolter telescopes.

  8. Steps towards Smarter Solutions in Optometry and Ophthalmology-Inter-Device Agreement of Subjective Methods to Assess the Refractive Errors of the Eye.

    PubMed

    Ohlendorf, Arne; Leube, Alexander; Wahl, Siegfried

    2016-07-13

    To investigate the inter-device agreement and mean differences between a newly developed digital phoropter and the two standard methods (trial frame and manual phoropter). Refractive errors of two groups of participants were measured by two examiners (examiner 1 (E1): 36 subjects; examiner 2 (E2): 38 subjects). Refractive errors were assessed using a trial frame, a manual phoropter and a digital phoropter. Inter-device agreement regarding the measurement of refractive errors was analyzed for differences in terms of the power vector components (spherical equivalent (SE) and the cylindrical power vector components J0 and J45) between the used methods. Intraclass correlation coefficients (ICC's) were calculated to evaluate correlations between the used methods. Analyzing the variances between the three methods for SE, J0 and J45 using a two-way ANOVA showed no significant differences between the methods (SE: p = 0.13, J0: p = 0.58 and J45: p = 0.96) for examiner 1 and for examiner 2 (SE: p = 0.88, J0: p = 0.95 and J45: p = 1). Mean differences and ±95% Limits of Agreement for each pair of inter-device agreement regarding the SE for both examiners were as follows: Trial frame vs. digital phoropter: +0.10 D ± 0.56 D (E1) and +0.19 D ± 0.60 D (E2), manual phoropter vs. trial frame: -0.04 D ± 0.59 D (E1) and -0.12 D ± 0.49 D (E2) and for manual vs. digital phoropter: +0.06 D ± 0.65 D (E1) and +0.08 D ± 0.45 D (E2). ICCs revealed high correlations between all methods for both examiner (p < 0.001). The time to assess the subjective refraction was significantly smaller with the digital phoropter (examiner 1: p < 0.001; examiner 2: p < 0.001). "All used subjective methods show a good agreement between each other terms of ICC (>0.9). Assessing refractive errors using different subjective methods, results in similar mean differences and 95% limits of agreement, when compared to those reported in studies comparing subjective refraction non-cylcoplegic retinoscopy or autorefraction".

  9. Steps towards Smarter Solutions in Optometry and Ophthalmology—Inter-Device Agreement of Subjective Methods to Assess the Refractive Errors of the Eye

    PubMed Central

    Ohlendorf, Arne; Leube, Alexander; Wahl, Siegfried

    2016-01-01

    Purpose: To investigate the inter-device agreement and mean differences between a newly developed digital phoropter and the two standard methods (trial frame and manual phoropter). Methods: Refractive errors of two groups of participants were measured by two examiners (examiner 1 (E1): 36 subjects; examiner 2 (E2): 38 subjects). Refractive errors were assessed using a trial frame, a manual phoropter and a digital phoropter. Inter-device agreement regarding the measurement of refractive errors was analyzed for differences in terms of the power vector components (spherical equivalent (SE) and the cylindrical power vector components J0 and J45) between the used methods. Intraclass correlation coefficients (ICC’s) were calculated to evaluate correlations between the used methods. Results: Analyzing the variances between the three methods for SE, J0 and J45 using a two-way ANOVA showed no significant differences between the methods (SE: p = 0.13, J0: p = 0.58 and J45: p = 0.96) for examiner 1 and for examiner 2 (SE: p = 0.88, J0: p = 0.95 and J45: p = 1). Mean differences and ±95% Limits of Agreement for each pair of inter-device agreement regarding the SE for both examiners were as follows: Trial frame vs. digital phoropter: +0.10 D ± 0.56 D (E1) and +0.19 D ± 0.60 D (E2), manual phoropter vs. trial frame: −0.04 D ± 0.59 D (E1) and −0.12 D ± 0.49 D (E2) and for manual vs. digital phoropter: +0.06 D ± 0.65 D (E1) and +0.08 D ± 0.45 D (E2). ICCs revealed high correlations between all methods for both examiner (p < 0.001). The time to assess the subjective refraction was significantly smaller with the digital phoropter (examiner 1: p < 0.001; examiner 2: p < 0.001). Conclusion: “All used subjective methods show a good agreement between each other terms of ICC (>0.9). Assessing refractive errors using different subjective methods, results in similar mean differences and 95% limits of agreement, when compared to those reported in studies comparing subjective refraction non-cylcoplegic retinoscopy or autorefraction”. PMID:27417629

  10. Characterization of Particle Size Standard NIST 1019b with SynchrotronX-ray Microtomography and Digital Data Extraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Friedrich, Jon M.; Rivers, Mark L.; Perlowitz, Michael A.

    We show that synchrotron x-ray microtomography ({mu}CT) followed by digital data extraction can be used to examine the size distribution and particle morphologies of the polydisperse (750 to 2450 {micro}m diameter) particle size standard NIST 1019b. Our size distribution results are within errors of certified values with data collected at 19.5 {micro}m/voxel. One of the advantages of using {mu}CT to investigate the particles examined here is that the morphology of the glass beads can be directly examined. We use the shape metrics aspect ratio and sphericity to examine of individual standard beads morphologies as a function of spherical equivalent diameters.more » We find that the majority of standard beads possess near-spherical aspect ratios and sphericities, but deviations are present at the lower end of the size range. The majority (> 98%) of particles also possess an equant form when examined using a common measure of equidimensionality. Although the NIST 1019b standard consists of loose particles, we point out that an advantage of {mu}CT is that coherent materials comprised of particles can be examined without disaggregation.« less

  11. Single-particle studies of band alignment effects on electron transfer dynamics from semiconductor hetero-nanostructures to single-walled carbon nanotubes.

    PubMed

    Yuan, Chi-Tsu; Wang, Yong-Gang; Huang, Kuo-Yen; Chen, Ting-Yu; Yu, Pyng; Tang, Jau; Sitt, Amit; Banin, Uri; Millo, Oded

    2012-01-24

    We utilize single-molecule spectroscopy combined with time-correlated single-photon counting to probe the electron transfer (ET) rates from various types of semiconductor hetero-nanocrystals, having either type-I or type-II band alignment, to single-walled carbon nanotubes. A significantly larger ET rate was observed for type-II ZnSe/CdS dot-in-rod nanostructures as compared to type-I spherical CdSe/ZnS core/shell quantum dots and to CdSe/CdS dot-in-rod structures. Furthermore, such rapid ET dynamics can compete with both Auger and radiative recombination processes, with significance for effective photovoltaic operation. © 2011 American Chemical Society

  12. Comparison of three techniques in measuring progressive addition lenses.

    PubMed

    Huang, Ching-Yao; Raasch, Thomas W; Yi, Allen Y; Sheedy, James E; Andre, Brett; Bullimore, Mark A

    2012-11-01

    To measure progressive addition lenses (PALs) by three techniques and to compare the differences across techniques. Five contemporary PALs (Varilux Comfort Enhanced, Varilux Physio Enhanced, Hoya Lifestyle, Shamir Autograph, and Zeiss individual) with plano distance power and a +2.00 diopters (D) add were evaluated under the condition of lateral displacement of the lens (no rotation and no tilt) using three methods. A Hartmann-Shack wavefront sensor (HSWFS) on a custom-built optical bench was used to capture and measure wavefront aberrations. A Rotlex Class Plus lens analyzer operating as a moiré interferometer was used to measure spherical and cylindrical powers. A coordinate measuring machine (CMM) was used to measure front and back surfaces of PALs and converted to desired optical properties. The data were analyzed with MATLAB programs. Contour plots of spherical equivalent power, cylindrical power, and higher-order aberrations (HOAs) in all PALs were generated to compare their differences. The differences in spherical equivalent and cylinder at distance, near, and progressive corridor areas among the HSWFS, Rotlex, and CMM methods were close to zero in all five PALs. The maximum differences are approximately 0.50 D and located below the near power zone and the edge areas of the lens when comparing the HSWFS and CMM with the Rotlex. HOAs measured both by the HSWFS and CMM were highest in the corridor area and the area surrounding the near zone in all PALs. The HOAs measured by the CMM were lower than those from the HSWFS by 0.02 to 0.04 μm. The three measurement methods are comparable for measuring spherical and cylindrical power across PALs. The non-optical method, CMM, can be used to evaluate the optical properties of a PAL by measuring front and back surface height measurements, although its estimates of HOAs are lower than those from the HSWFS.

  13. Navier-Stokes structure of merged layer flow on the spherical nose of a space vehicle

    NASA Technical Reports Server (NTRS)

    Jain, A. C.; Woods, G. H.

    1988-01-01

    Hypersonic merged layer flow on the forepart of a spherical surface of a space vehicle has been investigated on the basis of the full steady-state Navier-Stokes equations using slip and temperature jump boundary conditions at the surface and free-stream conditions far from the surface. The shockwave-like structure was determined as part of the computations. Using an equivalent body concept, computations were carried out under conditions that the Aeroassist Flight Experiment (AFE) Vehicle would encounter at 15 and 20 seconds in its flight path. Emphasis was placed on understanding the basic nature of the flow structure under low density conditions. Particular attention was paid to the understanding of the structure of the outer shockwave-like region as the fluid expands around the sphere. Plots were drawn for flow profiles and surface characteristics to understand the role of dissipation processes in the merged layer of the spherical nose of the vehicle.

  14. Variational extension of the mean spherical approximation to arbitrary dimensions

    NASA Astrophysics Data System (ADS)

    Velázquez, Esov S.; Blum, Lesser; Frisch, Harry L.

    1997-10-01

    We generalize a variational principle for the mean spherical approximation for a system of charged hard spheres in 3D to arbitrary dimensions. We first construct a free energy variational trial function from the Debye-Hückel excess charging internal energy at a finite concentration and an entropy obtained at the zero-concentration limit by thermodynamic integration. In three dimensions the minimization of this expression with respect to the screening parameter leads to the mean spherical approximation, usually obtained by solution of the Ornstein-Zernike equation. This procedure, which interpolates naturally between the zero concentration/coupling limit and the high-concentration/ coupling limit, is extended to arbitrary dimensions. We conjecture that this result is also equivalent to the MSA as originally defined, although a technical proof of this point is left for the future. The Onsager limit T ΔS MSA / ΔE MSA → 0 for infinite concentration/coupling is satisfied for all d ≠ 2, while for d=2 this limit is 1.

  15. Magnetic Inertial Confinement Fusion (MICF)

    NASA Astrophysics Data System (ADS)

    Miao, Feng; Zheng, Xianjun; Deng, Baiquan; Liu, Wei; Ou, Wei; Huang, Yi

    2016-11-01

    Based on the similarity in models of the early Sun and the 3-D common focal region of the micro-pinch in X-pinch experiments, a novel hybrid fusion configuration by continuous focusing of multiple Z-pinched plasma beams on spatially symmetric plasma is proposed. By replacing gravity with Lorentz force with subsequent centripetal spherical pinch, the beam-target fusion reactivity is enhanced in a quasi-spherical converging region, thus achieving MICF. An assessment, presented here, suggests that a practical fusion power source could be achieved using deuterium alone. Plasma instabilities can be suppressed by fast rotation resulting from an asymmetric tangential torsion in the spherical focal region of this configuration. Mathematical equivalence with the Sun allows the development of appropriate equations for the focal region of MICF, which are solved numerically to provide density, temperature and pressure distributions that produce net fusion energy output. An analysis of MICF physics and a preliminary experimental demonstration of a single beam are also carried out. supported by National Natural Science Foundation of China (Nos. 11374217 and 11176020)

  16. Equivalent Quantum Equations in a System Inspired by Bouncing Droplets Experiments

    NASA Astrophysics Data System (ADS)

    Borghesi, Christian

    2017-07-01

    In this paper we study a classical and theoretical system which consists of an elastic medium carrying transverse waves and one point-like high elastic medium density, called concretion. We compute the equation of motion for the concretion as well as the wave equation of this system. Afterwards we always consider the case where the concretion is not the wave source any longer. Then the concretion obeys a general and covariant guidance formula, which leads in low-velocity approximation to an equivalent de Broglie-Bohm guidance formula. The concretion moves then as if exists an equivalent quantum potential. A strictly equivalent free Schrödinger equation is retrieved, as well as the quantum stationary states in a linear or spherical cavity. We compute the energy (and momentum) of the concretion, naturally defined from the energy (and momentum) density of the vibrating elastic medium. Provided one condition about the amplitude of oscillation is fulfilled, it strikingly appears that the energy and momentum of the concretion not only are written in the same form as in quantum mechanics, but also encapsulate equivalent relativistic formulas.

  17. Anion-Anion Bonding and Topology in Ternary Iridium Seleno-Stannides.

    PubMed

    Trump, Benjamin A; Tutmaher, Jake A; McQueen, Tyrel M

    2015-12-21

    The synthesis and physical properties of two new and one known Ir-Sn-Se compound are reported. Their crystal structures are elucidated with transmission electron microscopy and powder X-ray diffraction. IrSn0.45Se1.55 is a pyrite phase which consists of tilted corner-sharing IrX6 octahedra with randomly distributed (Sn-Se)(4-) and (Se-Se)(2-) dimers. Ir2Sn3Se3 is a known trigonally distorted skutterudite that consists of cooperatively tilted corner-sharing IrSn3Se3 octahedra with ordered (Sn-Se)2(4-) tetramers. Ir2SnSe5 is a layered, distorted β-MnO2 (pyrolusite) structure consisting of a double IrSe6 octrahedral row, corner sharing in the a direction and edge sharing in the b direction. This distorted pyrolusite contains (Se-Se)(2-) dimers and Se(2-) anions, and each double row is "capped" with a (Sn-Se)n polymeric chain. Resistivity, specific heat, and magnetization measurements show that all three have insulating and diamagnetic behavior, indicative of low-spin 5d(6) Ir(3+). Electronic structure calculations on Ir2Sn3Se3 show a single, spherical, nonspin-orbit split valence band and suggest that Ir2Sn3Se3 is topologically nontrivial under tensile strain due to inversion of Ir-d and Se-p states.

  18. Instrumentation for investigation of the depth-dose distribution by the Liulin-5 instrument of a human phantom on the Russian segment of ISS for estimation of the radiation risk during long term space flights

    NASA Technical Reports Server (NTRS)

    Semkova, J.; Koleva, R.; Todorova, G.; Kanchev, N.; Petrov, V.; Shurshakov, V.; Tchhernykh, I.; Kireeva, S.

    2004-01-01

    Described is the Liulin-5 experiment and instrumentation, developed for investigation of the space radiation doses depth distribution in a human phantom on the Russian Segment of the International Space Station (ISS). Liulin-5 experiment is a part of the international project MATROSHKA-R on ISS. The experiment MATROSHKA-R is aimed to study the depth dose distribution at the sites of critical organs of the human body, using models of human body-anthropomorphic and spherical tissue-equivalent phantoms. The aim of Liulin-5 experiment is long term (4-5 years) investigation of the radiation environment dynamics inside the spherical tissue-equivalent phantom, mounted in different places of the Russian Segment of ISS. Energy deposition spectra, linear energy transfer spectra, flux and dose rates for protons and the biologically-relevant heavy ion components of the galactic cosmic radiation will be measured simultaneously with near real time resolution at different depths of the phantom by a telescope of silicon detectors. Data obtained together with data from other active and passive dosimeters will be used to estimate the radiation risk to the crewmembers, verify the models of radiation environment in low Earth orbit, validate body transport model and correlate organ level dose to skin dose. Presented are the test results of the prototype unit. The spherical phantom will be flown on the ISS in 2004 year and Liulin-5 experiment is planned for 2005 year. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

  19. A fast algorithm for forward-modeling of gravitational fields in spherical coordinates with 3D Gauss-Legendre quadrature

    NASA Astrophysics Data System (ADS)

    Zhao, G.; Liu, J.; Chen, B.; Guo, R.; Chen, L.

    2017-12-01

    Forward modeling of gravitational fields at large-scale requires to consider the curvature of the Earth and to evaluate the Newton's volume integral in spherical coordinates. To acquire fast and accurate gravitational effects for subsurface structures, subsurface mass distribution is usually discretized into small spherical prisms (called tesseroids). The gravity fields of tesseroids are generally calculated numerically. One of the commonly used numerical methods is the 3D Gauss-Legendre quadrature (GLQ). However, the traditional GLQ integration suffers from low computational efficiency and relatively poor accuracy when the observation surface is close to the source region. We developed a fast and high accuracy 3D GLQ integration based on the equivalence of kernel matrix, adaptive discretization and parallelization using OpenMP. The equivalence of kernel matrix strategy increases efficiency and reduces memory consumption by calculating and storing the same matrix elements in each kernel matrix just one time. In this method, the adaptive discretization strategy is used to improve the accuracy. The numerical investigations show that the executing time of the proposed method is reduced by two orders of magnitude compared with the traditional method that without these optimized strategies. High accuracy results can also be guaranteed no matter how close the computation points to the source region. In addition, the algorithm dramatically reduces the memory requirement by N times compared with the traditional method, where N is the number of discretization of the source region in the longitudinal direction. It makes the large-scale gravity forward modeling and inversion with a fine discretization possible.

  20. [Comparison of refraction with or without cycloplegia using Retinomax® or Plusoptix® devices].

    PubMed

    Bui Quoc, E; Guilmin Crepon, S; Tinguely, S; Lavallee, G; Busquet, G; Angot, M; Vera, L

    2017-03-01

    To evaluate the refraction in children measured with Plusoptix ® without cycloplegia vs. Retinomax ® apparatus with cycloplegia. Measure of refraction with Plusoptix ® in children>1year old referred for systematic vision screening, then measurement after cycloplegia with cyclopentolate by the Retinomax ® device. Thirty-three children were included, i.e. 66eyes. Mean age was 40.7months (minimum 12; maximum 114). The Spearman correlation coefficient for the spherical equivalent was 0.52 (Plusoptix ® vs. Retinomax ® comparison; P<0.0001=moderate correlation). The Spearman correlation coefficient was 0.73 for astigmatism (Plusoptix ® vs. Retinomax ® comparison; P<0.0001=strong correlation). The Plusoptix ® sensitivity for measurement of refraction was 57%, 43% and 43% respectively for spherical equivalent, sphere and astigmatism. The correlation of astigmatism values is strong, whereas the correlation of sphere values is moderate. Plusoptix ® seems to be unable to measure the exact refraction, because there is too large a dispersion of refraction measurements with Plusoptix ® , compared to the exact refraction measured with the Retinomax ® . Moreover, the sensitivity of Plusoptix ® is low. Cycloplegic refraction remains indispensable in children. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  1. Achieving target refraction after cataract surgery.

    PubMed

    Simon, Shira S; Chee, Yewlin E; Haddadin, Ramez I; Veldman, Peter B; Borboli-Gerogiannis, Sheila; Brauner, Stacey C; Chang, Kenneth K; Chen, Sherleen H; Gardiner, Matthew F; Greenstein, Scott H; Kloek, Carolyn E; Chen, Teresa C

    2014-02-01

    To evaluate the difference between target and actual refraction after phacoemulsification and intraocular lens implantation at an academic teaching institution's Comprehensive Ophthalmology Service. Retrospective study. We examined 1275 eye surgeries for this study. All consecutive cataract surgeries were included if they were performed by an attending or resident surgeon from January through December 2010. Postoperative refractions were compared with preoperative target refractions. Patients were excluded if they did not have a preoperative target refraction documented or if they did not have a recorded postoperative manifest refraction within 90 days. The main outcome measure was percentage of cases achieving a postoperative spherical equivalent ± 1.0 diopter (D) of target spherical equivalent. We performed 1368 cataract surgeries from January through December of 2010. Of these, 1275 (93%) had sufficient information for analysis. Of the included cases, 94% (1196 of 1275) achieved ± 1.0 D of target refraction by 90 days after cataract surgery. This paper establishes a new benchmark for a teaching hospital, where 94% of patients achieved within 1.0 D of target refraction after cataract surgery. The refractive outcomes after cataract surgery at this academic teaching institution were higher than average international benchmarks. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  2. On the Relation Between Spherical Harmonics and Simplified Spherical Harmonics Methods

    NASA Astrophysics Data System (ADS)

    Coppa, G. G. M.; Giusti, V.; Montagnini, B.; Ravetto, P.

    2010-03-01

    The purpose of the paper is, first, to recall the proof that the AN method and, therefore, the SP2N-1 method (of which AN was shown to be a variant) are equivalent to the odd order P2N-1, at least for a particular class of multi-region problems; namely the problems for which the total cross section has the same value for all the regions and the scattering is supposed to be isotropic. By virtue of the introduction of quadrature formulas representing first collision probabilities, this class is then enlarged in order to encompass the systems in which the regions may have different total cross sections. Some examples are reported to numerically validate the procedure.

  3. Anion–Anion Bonding and Topology in Ternary Iridium Seleno–Stannides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trump, Benjamin A.; Tutmaher, Jake A.; McQueen, Tyrel M.

    2015-12-21

    The synthesis and physical properties of two new and one known Ir–Sn–Se compound are reported. Their crystal structures are elucidated with transmission electron microscopy and powder X-ray diffraction. IrSn0.45Se1.55 is a pyrite phase which consists of tilted corner-sharing IrX6 octahedra with randomly distributed (Sn–Se)4– and (Se–Se)2– dimers. Ir2Sn3Se3 is a known trigonally distorted skutterudite that consists of cooperatively tilted corner-sharing IrSn3Se3 octahedra with ordered (Sn–Se)24– tetramers. Ir2SnSe5 is a layered, distorted β-MnO2 (pyrolusite) structure consisting of a double IrSe6 octrahedral row, corner sharing in the a direction and edge sharing in the b direction. This distorted pyrolusite contains (Se–Se)2– dimersmore » and Se2– anions, and each double row is “capped” with a (Sn–Se)n polymeric chain. Resistivity, specific heat, and magnetization measurements show that all three have insulating and diamagnetic behavior, indicative of low-spin 5d6 Ir3+. Electronic structure calculations on Ir2Sn3Se3 show a single, spherical, nonspin–orbit split valence band and suggest that Ir2Sn3Se3 is topologically nontrivial under tensile strain due to inversion of Ir-d and Se-p states.« less

  4. Children's Cosmographies: Understanding the Earth's Shape and Gravity.

    ERIC Educational Resources Information Center

    Sneider, Cary; Pulos, Steven

    1983-01-01

    Assessed Nussbaum's developmental model (SE 024 045) using a new sample given no special instructions in spherical earth/gravity concepts. Also identified distribution of notions among students (N=159 in grades three to eight), compared distribution of notions at each age level with those in other studies, and explored role of individual…

  5. Small-incision lenticule extraction (SMILE): outcomes of 722 eyes treated for myopia and myopic astigmatism.

    PubMed

    Hansen, Rasmus Søgaard; Lyhne, Niels; Grauslund, Jakob; Vestergaard, Anders Højslet

    2016-02-01

    To study the outcomes of small-incision lenticule extraction (SMILE) for treatment of myopia and myopic astigmatism. Retrospective study of patients treated for myopia or myopic astigmatism with SMILE, using a VisuMax(®) femtosecond laser (Carl Zeiss Meditec, Jena, Germany), at the Department of Ophthalmology, Odense University Hospital, Odense, Denmark. Inclusion criteria were corrected distance visual acuity (CDVA) of 20/25 or better before surgery and no ocular conditions other than myopia up to -10.00 diopters (D) with astigmatism up to 3.00 D. Of the 729 treatments, 722 were included. The spherical equivalent (SE) refraction averaged -6.82 ± 1.66 diopters (D) before surgery. After 3 months, 88 % of eyes were within ±0.50 D of the intended refraction, whilst 98 % were within ±1.00 D. The mean difference between attempted and achieved SE refraction at 3 months after surgery was -0.06 ± 0.01 D (range: -1.25 to 1.25 D). In eyes with emmetropia as target refraction (n = 362), 63 % had uncorrected distance visual acuity (UDVA) of 20/25 or better 1 day after surgery, rising to 83 % at 3 months after surgery. The average gain in CDVA from before surgery to 3 months after surgery was 0.07 ± 0.03 (logMAR). However, 12 eyes (1.6 %) lost 2 or more lines of CDVA from before surgery to 3 months postoperatively. Simultaneous treatment of up to 3.00 D of astigmatism was not associated with less predictable refractive outcomes. In the short term, SMILE seemed predictable, efficient, and safe for treatment of myopia and myopic astigmatism.

  6. [Visual outcomes 5 years after small incision lenticule extraction (SMILE), surgery on spherocylindrical myopia eyes, from 616 eyes].

    PubMed

    Burazovitch, J; Ferguene, H; Naguszewski, D

    2018-05-15

    Determine if the visual criteria of the technique of surgery refractive by Femtosecond Laser-assisted duckweed Extraction - Small Lenticule Extraction (FLEx-Smile ® ), realized in the laser femtosecond VisuMax ® (Carl Zeiss Meditec, Jena, Germany), are stable, secure, effective and predictable in the long term, to the nearsighted and astigmatic. Retrospective study, monocentric with data collected between March 2012 and March 2017. The study included 616 eyes of 309 nearsighted and astigmatic patients (spherical equivalent from 1 to 11 D). They were followed in postoperative immediate (D+1), in 3 months, in 1 year and in 5 years. The taken measures include the refraction, the uncorrected visual acuteness (UVAC) and the best visual corrected acuteness (BVAC). The criteria of evaluation were based on the BVAC, the refractive stability, the index of security (IS: MAVC to preoperative D+1/BVAC before operation) and the predictability (percentage of eyes in±1 D of SE target). UVAC was better 5th year than after the intervention (P=0.001) and 88% of the operated eyes had an UVAC in 8/10 (logMAR=0.1). For the stability refractive, the patients became nearsighted between the intervention and 5th year (P=0.001), with a regression of 0.240 D. The indication of safety was better 5th year than the day after the intervention (P=0.001), 92% of eyes operated in 5 years were 0.5 D of SE target and 77% of eyes had lost no line. SMILE is a good technique of surgery refractive stable, secure, effective and predictable on the long term. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  7. Short-term outcomes of small-incision lenticule extraction (SMILE) for low, medium, and high myopia.

    PubMed

    Fernández, Joaquín; Valero, Almudena; Martínez, Javier; Piñero, David P; Rodríguez-Vallejo, Manuel

    2017-03-10

    To determine the safety, efficacy, and predictability of small-incision lenticule extraction at 6-month follow-up, depending on the level of the myopic refractive error. The surgeries were performed by a surgeon new to this technique. Seventy-one subjects with a mean age of 31.86 ± 5.57 years were included in this retrospective observational study. Subjects were divided into 3 groups depending on the preoperative spherical equivalent (SE): low group from -1.00 D to -3.00 D, medium from -3.25 D to -5.00 D, and high from -5.25 D to -7.00 D. Manifest refraction, corrected distance visual acuity (CDVA), and uncorrected distance visual acuity (UDVA) were measured before surgery and at 6 months after the treatment. In total, 1.4% of the eyes lost 1 line of CDVA after the procedure, whereas 95.8% remained unchanged and 2.8% gained 1 line. A significant undercorrection (p = 0.031) was found in the high myopia group (median -0.50 D), whereas the low and medium groups remained near to emmetropia. In terms of efficacy, no statistically significant intergroup differences for postoperative UDVA (p = 0.282) were found. The vector analysis also showed undercorrection of the preoperative cylinder, even though the standard deviations decreased from 0.9 D in the x axis and 0.7 D in the y axis to 0.24 D and 0.27 D, respectively. Small-incision lenticule extraction might be a safe, effective, and predictable procedure even for inexperienced surgeons. No differences in efficacy were found among myopia levels even though undercorrections were found for SE and cylinder in high myopia.

  8. Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective study.

    PubMed

    Sekundo, Walter; Kunert, Kathleen S; Blum, Marcus

    2011-03-01

    This 6 month prospective multi-centre study evaluated the feasibility of performing myopic femtosecond lenticule extraction (FLEx) through a small incision using the small incision lenticule extraction (SMILE) procedure. Prospective, non-randomised clinical trial. PARTICIPANTS; Ninety-one eyes of 48 patients with myopia with and without astigmatism completed the final 6 month follow-up. The patients' mean age was 35.3 years. Their preoperative mean spherical equivalent (SE) was −4.75±1.56 D. A refractive lenticule of intrastromal corneal tissue was cut utilising a prototype of the Carl Zeiss Meditec AG VisuMax femtosecond laser system. Simultaneously two opposite small ‘pocket’ incisions were created by the laser system. Thereafter, the lenticule was manually dissected with a spatula and removed through one of incisions using modified McPherson forceps. Uncorrected visual acuity (UCVA) and best spectacle corrected visual acuity (BSCVA) after 6 months, objective and manifest refraction as well as slit-lamp examination, side effects and a questionnaire. Six months postoperatively the mean SE was −0.01 D±0.49 D. Most treated eyes (95.6%) were within ±1.0 D, and 80.2% were within ±0.5 D of intended correction. Of the eyes treated, 83.5% had an UCVA of 1.0 (20/20) or better, 53% remained unchanged, 32.3% gained one line, 3.3% gained two lines of BSCVA, 8.8% lost one line and 1.1% lost ≥2 lines of BSCVA. When answering a standardised questionnaire, 93.3% of patients were satisfied with the results obtained and would undergo the procedure again. SMILE is a promising new flapless minimally invasive refractive procedure to correct myopia.

  9. Efficacy and safety of cross-cylinder photorefractive keratectomy versus single method in medium-high astigmatism: a randomized clinical trial.

    PubMed

    Sedghipour, Mohammad R; Lotfi, Afshin; Sadeghilar, Ayaz; Banan, Saeeid

    2012-09-07

    BACKGROUND: To compare efficacy and safety of photorefractive keratectomy (PRK) by cross-cylinder with single methods in medium-high astigmatism. DESIGN: Randomized clinical trial study PARTICIPANTS: Fifty patients with medium-high compound myopic astigmatism were enrolled between September 2007 and September 2008. METHODS: PRK was performed on 100 eyes of 50 patients with compound myopic astigmatism. Each patient underwent PRK by cross-cylinder approach in one eye and single method on the contralateral eye. Vector analysis was used to assess astigmatic results. MAIN OUTCOME MEASURES: Improvement of visual acuity (snelen chart), refraction, aberrometry. RESULTS: Uncorrected visual acuity (UCCA) equal to 20/40 or better after six months, was achieved in 98% of eyes in the cross-cylinder method versus 96% in single method.. Mean preoperative spherical equivalent(SE) was -5.2 ±2.1 D in the cross-cylinder method versus -5.1 ±0.5 D in the single method. At six months, the mean SE was - 0.5±0.4 D and -0.6±0.3 D, respectively. Mean IOS was 0.4±0.3 in the cross-cylinder group and 0.4±0.4 in the single group. Mean postoperative absolute change in total root-mean-square higher order aberrations in the cross-cylinder group and single group were 0.16 pm and 0.17 pm, respectively. Any of the mentioned differences didn't appear to be statistically significant. CONCLUSIONS: Both PRK methods appeared to be safe and effective in correcting medium-high astigmatism. © 2012 The Author. Clinical and Experimental Ophthalmology © 2012 Royal Australian and New Zealand College of Ophthalmologists.

  10. Cycloplegic autorefraction in young adults: is it mandatory?

    PubMed

    Mimouni, Michael; Zoller, Lilach; Horowitz, Josefa; Wygnanski-Jaffe, Tamara; Morad, Yair; Mezer, Eedy

    2016-02-01

    The precise correction of refractive error is especially important in young adults. It is unclear whether cycloplegic refraction is necessary in this age group. The purpose of this study was to compare the non-cycloplegic and cycloplegic spherical equivalent (SE) refractive error measured in young adults. This was a prospective study of 1400 eyes (n = 700) of enlisted soldiers aged 18 to 21 years who were consecutively evaluated in an outpatient army ophthalmology clinic. One drop of cyclopentolate 1 % was installed twice 10 min apart, and cycloplegic refraction was performed in both eyes 40 min later using an auto-refractor. The difference between non-cycloplegic and cycloplegic refractive measurements was analyzed. The mean difference in SE between non-cycloplegic and cycloplegic measurements was 0.68 ± 0.83 D (95 % CI, 0.64-0.72). Significantly greater differences were observed in hypermetropes than myopes (1.30 ± 0.90 D versus 0.46 ± 0.68 D, p < 0.001). Moderate hypermetropes (2 to 5 D) demonstrated significantly greater refractive error than mild (0.5 to 2 D) or severe (>5 D) hypermetropes (1.71 ± 1.18 D versus 1.19 ± 0.74 D and 1.16 ± 1.08 D respectively, p < 0.001). Young hypermetropic adults possessed +1 to +2 D of latent hypermetropia. In contrast, young myopic adults revealed pseudomyopia of -0.5 D. Cycloplegic refraction should be performed in young hypermetropic adults complaining of various signs of asthenopia.

  11. Outcomes of Retreatment after Aborted Laser In Situ Keratomileusis due to Flap Complications.

    PubMed

    Al-Mezaine, Hani S; Al-Amro, Saleh A; Al-Fadda, Abdulaziz; Al-Obeidan, Saleh

    2011-07-01

    To determine the refractive outcomes and complications of retreatment after aborted primary laser in situ keratomileusis (LASIK) due to flap complications. This retrospective study evaluated 50 retreated eyes that had flap complications during primary LASIK at the Eye Consultants Center in Riyadh, Saudi Arabia. Data were analyzed for patients with at least 3 months follow-up post retreatment. Thirty-three eyes of 31 consecutive patients with 3 months follow-up or later post retreatment were included. The primary LASIK was aborted due to incomplete flaps in 22 eyes (66.7%), buttonhole flaps in 7 eyes (21.2%), free partial flaps in 3 eyes (9.1%), and a free complete flap in 1 eye (3.0%). Twenty-two eyes (66.7%) were retreated with LASIK, and 11 eyes (33.3%) were retreated with surface ablation. The mean spherical equivalent (SE) was -0.23 ± 0.72 D, the mean astigmatism was -0.65 ± 0.89 D, and the mean loss of the best corrected visual acuity (BCVA) was 0.78 lines at the final postoperative visit. At the last postoperative visit, 20/30 or better BCVA was achieved in 90.1% of eyes that underwent retreatment with LASIK and in 91% of eyes that were retreated with surface ablation. There was no statistical difference in postoperative SE between eyes retreated with LASIK and eyes retreated with surface ablation (P = 0.610). There was no statistical difference in postoperative BCVA between eyes retreated with LASIK and those retreated with surface ablation (P = 0.756). There were no intraoperative complications and no eyes required a second retreatment. Creation of a flap after a previous intraoperative flap complication was not associated with any complications. The refractive outcomes of retreatment with LASIK or surface ablation were comparable and reasonably favorable.

  12. Myopia in young patients with type 1 diabetes mellitus.

    PubMed

    Handa, Swati; Chia, Audrey; Htoon, Hla Myint; Lam, Pin Min; Yap, Fabian; Ling, Yvonne

    2015-08-01

    This study aimed to evaluate the proportion of young patients with type 1 diabetes mellitus (T1DM) who have myopia, as well as the risk factors associated with myopia in this group. In this cross-sectional study, patients aged < 21 years with T1DM for ≥ 1 year underwent a comprehensive eye examination. Presence of parental myopia, and average hours of near-work and outdoor activity were estimated using a questionnaire. Annualised glycosylated haemoglobin (HbA1c), defined as the mean of the last three HbA1c readings taken over the last year, was calculated. Multivariate analysis using genetic, environmental and diabetes-related factors was done to evaluate risk factors associated with myopia. Of the 146 patients (mean age 12.5 ± 3.6 years) recruited, 66.4% were Chinese and 57.5% were female. Myopia (i.e. spherical equivalent [SE] of -0.50 D or worse) was present in 96 (65.8%) patients. The proportion of patients with myopia increased from 25.0% and 53.6% in those aged < 7.0 years and 7.0-9.9 years, respectively, to 59.2% and 78.4% in those aged 10.0-11.9 years and ≥ 12.0 years, respectively. Higher levels of SE were associated with lower parental myopia (p = 0.024) and higher annualised HbA1c (p = 0.011). Compared to the background population, the proportion of myopia in young patients with T1DM was higher in those aged < 10 years but similar in the older age group. Myopia was associated with a history of parental myopia. Environmental risk factors and poor glycaemic control were not related to higher myopia risk.

  13. The Association between Maternal Reproductive Age and Progression of Refractive Error in Urban Students in Beijing

    PubMed Central

    Vasudevan, Balamurali; Jin, Zi Bing; Ciuffreda, Kenneth J.; Jhanji, Vishal; Zhou, Hong Jia; Wang, Ning Li; Liang, Yuan Bo

    2015-01-01

    Purpose To investigate the association between maternal reproductive age and their children’ refractive error progression in Chinese urban students. Methods The Beijing Myopia Progression Study was a three-year cohort investigation. Cycloplegic refraction of these students at both baseline and follow-up vision examinations, as well as non-cycloplegic refraction of their parents at baseline, were performed. Student’s refractive change was defined as the cycloplegic spherical equivalent (SE) of the right eye at the final follow-up minus the cycloplegic SE of the right eye at baseline. Results At the final follow-up, 241 students (62.4%) were reexamined. 226 students (58.5%) with completed refractive data, as well as completed parental reproductive age data, were enrolled. The average paternal and maternal age increased from 29.4 years and 27.5 years in 1993–1994 to 32.6 years and 29.2 years in 2003–2004, respectively. In the multivariate analysis, students who were younger (β = 0.08 diopter/year/year, P<0.001), with more myopic refraction at baseline (β = 0.02 diopter/year/diopter, P = 0.01), and with older maternal reproductive age (β = -0.18 diopter/year/decade, P = 0.01), had more myopic refractive change. After stratifying the parental reproductive age into quartile groups, children with older maternal reproductive age (trend test: P = 0.04) had more myopic refractive change, after adjusting for the children's age, baseline refraction, maternal refraction, and near work time. However, no significant association between myopic refractive change and paternal reproductive age was found. Conclusions In this cohort, children with older maternal reproductive age had more myopic refractive change. This new risk factor for myopia progression may partially explain the faster myopic progression found in the Chinese population in recent decades. PMID:26421841

  14. Visual outcomes after lensectomy and iris claw artisan intraocular lens implantation in patients with Marfan syndrome.

    PubMed

    Rabie, Hossein Mohammad; Malekifar, Parviz; Javadi, Mohammad Ali; Roshandel, Danial; Esfandiari, Hamed

    2017-08-01

    To review our experience with crystalline lens extraction and iris claw Artisan IOL implantation in patients with lens subluxation secondary to Marfan syndrome. A retrospective analysis of 12 eyes of 9 patients with lens subluxation due to Marfan syndrome who underwent crystalline lens removal and Artisan IOL (Ophtec, Groningen, Netherlands) implantation. A questionnaire of pre- and post-operative data, including demographics, pre- and postoperative comorbidities and complications was completed. Patients were evaluated for visual outcome and occurrence of complications. Uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), and spherical equivalents (SE) were compared before and after lens extraction and IOL insertion. The mean age of the participants was 30.03 ± 15.02 years, and mean post-operative follow-up time was 44.5 ± 16.4 months. Mean BCVA also showed a significant improvement from 0.5 ± 0.3 at the baseline to 0.2 ± 0.2 post-operatively (P = 0.006). SE changed significantly from -11.38 ± 1.99 preoperatively to -0.45 ± 1.65 post-operatively (P = 0.003). All eyes had the IOL implanted at desired position. Post-operative complications were retinal detachment in one case and IOL dislocation in another patient. No other complication such as ocular hypertension, angle abnormalities, clinical cystoids macular edema, and corneal decompensation was observed during the follow-up period. Artisan IOL implantation after lens extraction appears to be an attractive alternative for optical correction in cases of Marfan syndrome with ectopia lentis. It confers a significant improvement in visual acuity with reasonable risk profile.

  15. Prevalence of refractive errors in a multiethnic Asian population: the Singapore epidemiology of eye disease study.

    PubMed

    Pan, Chen-Wei; Zheng, Ying-Feng; Anuar, Ainur Rahman; Chew, Merwyn; Gazzard, Gus; Aung, Tin; Cheng, Ching-Yu; Wong, Tien Y; Saw, Seang-Mei

    2013-04-09

    To determine the prevalence of refractive errors in a multiethnic Asian population aged over 40 years and to examine secular trends and racial differences. A total of 10,033 adults (3353 Chinese, 3400 Indians, and 3280 Malays) participated in this study. Refractive error was determined by subjective refraction. Ocular biometric parameters were determined by partial coherence interferometry. Myopia and high myopia were defined as spherical equivalent (SE) of less than -0.5 diopters (D) and -5.0 D, respectively. Hyperopia was defined as SE of more than 0.5 D. Astigmatism was defined as cylinders less than -0.5 D. The prevalence of myopia, high myopia, hyperopia and astigmatism in Singapore adults aged over 40 years was 38.9% (95% confidence interval [CI] 37.1, 40.6); 8.4% (95% CI 8.0, 8.9); 31.5% (95% 30.5, 32.5); and 58.8% (95% CI 57.8, 59.9), respectively. Compared with the Tanjong Pagar Survey 12 years ago, there was a significant increase in the prevalence of astigmatism and mean axial length (AL) in Chinese adults aged over 40 years in Singapore. Chinese were most likely to be affected by myopia, high myopia, astigmatism, and had the longest AL among the three racial groups. The prevalence of myopia in Singapore adults is lower compared with the younger "myopia" generation in Singapore. The prevalence of astigmatism and mean AL have been increasing significantly within the past 12 years in the Chinese population. Chinese adults had higher prevalence of myopia, high myopia, astigmatism, as well as the longer AL compared with non-Chinese adults in Singapore.

  16. Comparison of visual outcomes after bilateral implantation of extended range of vision and trifocal intraocular lenses.

    PubMed

    Ruiz-Mesa, Ramón; Abengózar-Vela, Antonio; Aramburu, Ana; Ruiz-Santos, María

    2017-06-26

    To compare visual outcomes after cataract surgery with bilateral implantation of 2 intraocular lenses (IOLs): extended range of vision and trifocal. Each group of this prospective study comprised 40 eyes (20 patients). Phacoemulsification followed by bilateral implantation of a FineVision IOL (group 1) or a Symfony IOL (group 2) was performed. The following outcomes were assessed up to 1 year postoperatively: binocular uncorrected distance visual acuity (UDVA), binocular uncorrected intermediate visual acuity (UIVA) at 60 cm, binocular uncorrected near visual acuity (UNVA) at 40 cm, spherical equivalent (SE) refraction, defocus curves, mesopic and photopic contrast sensitivity, halometry, posterior capsule opacification (PCO), and responses to a patient questionnaire. The mean binocular values in group 1 and group 2, respectively, were SE -0.15 ± 0.25 D and -0.19 ± 0.18 D; UDVA 0.01 ± 0.03 logMAR and 0.01 ± 0.02 logMAR; UIVA 0.11 ± 0.08 logMAR and 0.09 ± 0.08 logMAR; UNVA 0.06 ± 0.07 logMAR and 0.17 ± 0.06 logMAR. Difference in UNVA between IOLs (p<0.05) was statistically significant. There were no significant differences in contrast sensitivity, halometry, or PCO between groups. Defocus curves were similar between groups from 0 D to -2 D, but showed significant differences from -2.50 D to -4.00 D (p<0.05). Both IOLs provided excellent distance and intermediate visual outcomes. The FineVision IOL showed better near visual acuity. Predictability of the refractive results and optical performance were excellent; all patients achieved spectacle independence. The 2 IOLs gave similar and good contrast sensitivity in photopic and mesopic conditions and low perception of halos by patients.

  17. Evaluation of retinal nerve fiber layer thickness in vernal keratoconjunctivitis patients under long-term topical corticosteroid therapy.

    PubMed

    Cingu, Abdullah Kursat; Cinar, Yasin; Turkcu, Fatih Mehmet; Sahinoglu-Keskek, Nedime; Sahin, Alparslan; Sahin, Muhammed; Yuksel, Harun; Caca, Ihsan

    2014-09-01

    The aim of this study was to evaluate the retinal nerve fiber layer (RNFL) thickness in vernal keratoconjunctivitis (VKC) patients who were under long-term topical corticosteroid therapy. Thirty-six eyes of 36 VKC patients with clear cornea and normal videokeratography and 40 eyes of 40 age- and gender-matched normal children were included in the study. Clinical and demographic characteristics of the patients were noted and detailed ophthalmological examination was performed. Visual acuity (VA), spherical equivalent (SE), axial length (AL) and RNFL thickness measurements were compared between the groups. To correct ocular magnification effect on RNFL, we used Littmann's formula. All VKC patients had history of topical corticosteroid use and the mean duration of the topical corticosteroid use was 23.8 ± 9.09 months. There was no significant difference between the groups in terms of intraocular pressure (IOP). VKC group had significantly worse VA, greater SE and AL and thinner mean global, superior and inferior RNFL thickness. There were significant negative correlations between the duration of topical corticosteroid use and the mean global, superior and temporal RNFL thickness in VKC group. After correction of magnification effect, VKC group still had thinner mean global, superior and inferior RNFL thickness, and significant difference between the groups in inferior RNFL thickness did not disappear. Significant RNFL thickness difference between the groups suggests a possible effect of long-term corticosteroid use in VKC patients. Because visual field (VF) analysis in pediatric patients is difficult to perform and IOP may be illusive, RNFL thickness measurements in addition to routine examinations in VKC patients may help clinicians in their practice.

  18. Peripheral Defocus and Myopia Progression in Myopic Children Randomly Assigned to Wear Single Vision and Progressive Addition Lenses

    PubMed Central

    Berntsen, David A.; Barr, Christopher D.; Mutti, Donald O.; Zadnik, Karla

    2013-01-01

    Purpose. To determine the effect of progressive addition lenses (PALs) and single vision lenses (SVLs) on peripheral defocus in myopic children, and to compare the effect of myopic versus hyperopic peripheral defocus on foveal myopia progression. Methods. Eighty-four myopic children aged 6 to 11 years with spherical equivalent (SE) cycloplegic autorefraction between −0.75 diopters (D) and −4.50 D were randomly assigned to wear SVLs or PALs. Aberrometry measurements of the eye and spectacles were made centrally, 30° nasally, temporally, and superiorly, and 20° inferiorly on the retina using a Complete Ophthalmic Analysis System for Vision Research (COAS-VR). The association between peripheral defocus and the 1-year change in central myopia was investigated. Results. SVLs caused a hyperopic shift in peripheral defocus at all locations (all P ≤ 0.0003). PALs caused a myopic shift in peripheral defocus in three of four locations measured (all P ≤ 0.01) with the greatest shift superiorly due to the PAL addition (−1.04 ± 0.30 D). Superior retinal defocus when wearing either SVLs or PALs was associated with the 1-year change in central myopia. The adjusted 1-year change in central SE myopia was −0.38 D for children with absolute superior myopic defocus (n = 67) and −0.65 D for children with absolute superior hyperopic defocus (n = 17; difference = 0.27 D; P = 0.002). Conclusions. PALs caused a myopic shift in peripheral defocus. Superior myopic defocus was associated with less central myopia progression. These data support the continued investigation of optical designs that result in peripheral myopic defocus as a potential way to slow myopia progression. (ClinicalTrials.gov number, NCT00335049.) PMID:23838771

  19. Biometric measurements in highly myopic eyes.

    PubMed

    Shen, Peiyang; Zheng, Yingfeng; Ding, Xiaohu; Liu, Bin; Congdon, Nathan; Morgan, Ian; He, Mingguang

    2013-02-01

    To assess the repeatability and accuracy of optical biometry (Lenstar LS900 optical low-coherence reflectometry [OLCR] and IOLMaster partial coherence interferometry [PCI]) and applanation ultrasound biometry in highly myopic eyes. Division of Preventive Ophthalmology, Zhongshan Ophthalmic Center, Guangzhou, China. Comparative evaluation of diagnostic technology. Biometric measurements were taken in highly myopic subjects with a spherical equivalent (SE) of -6.00 diopters (D) or higher and an axial length (AL) longer than 25.0 mm. Measurements of AL and anterior chamber depth (ACD) obtained by OLCR were compared with those obtained by PCI and applanation A-scan ultrasound. Right eyes were analyzed. Repeatability was evaluated using the coefficient of variation (CoV) and agreement, using Bland-Altman analyses. The mean SE was -11.20 D ± 4.65 (SD). The CoVs for repeated AL measurements using OLCR, PCI, and applanation ultrasound were 0.06%, 0.07%, and 0.20%, respectively. The limits of agreement (LoA) for AL were 0.11 mm between OLCR and PCI, 1.01 mm between OLCR and applanation ultrasound, and 1.03 mm between PCI and ultrasound. The ACD values were 0.29 mm, 0.53 mm, and 0.51 mm, respectively. These repeatability and agreement results were comparable in eyes with extreme myopia (AL ≥ 27.0 mm) or posterior staphyloma. The mean radius of corneal curvature was similar between OLCR and PCI (7.66 ± 0.24 mm versus 7.64 ± 0.25 mm), with an LoA of 0.12 mm. Optical biometry provided more repeatable and precise measurements of biometric parameters, including AL and ACD, than applanation ultrasound biometry in highly myopic eyes. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  20. Four-year visual outcomes after photorefractive keratectomy in pilots with low-moderate myopia.

    PubMed

    Moon, Chan Hee

    2016-02-01

    The photorefractive keratectomy (PRK) is approved for Air Force pilots in several nations. The occupational environments of pilots in the Air Force are unique, including extremely high altitude, low oxygen tension, high ultraviolet light exposure and high G-force load. The short-term efficacy and safety of PRK for pilots are documented. However, the study for long-term visual and refractive outcomes of PRK in pilots is limited. To investigate the long-term visual and refractive outcomes in a 4-year follow-up period after PRK in pilots with low to moderate myopia. Thirty-eight eyes of 20 subjects that underwent PRK and recruited to Air Force pilot were evaluated preoperatively and at 3, 6, 12, 24, and 48 months postoperatively. The mean patient age was 21.42±0.75 years. The mean preoperative manifest refraction spherical equivalent (SE) was -1.51±1.15 diopters (D). At 4 years postoperatively, the mean SE was -0.29±0.51, 89.5% of eyes achieved 20/20 or better Snellen uncorrected visual acuity, 71.1% of eyes were within ±0.50 D of emmetropia. The refraction stabilised by 6 months and was maintained up to the 4-year follow-up stage. PRK for pilots with low to moderate myopia is safe and effective in the long term. High-altitude environmental stress exposure has no effect on the refractive stability after PRK. ROKAF-ASMC-2015-IRB-002. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  1. Evaluation of a Myopic Normative Database for Analysis of Retinal Nerve Fiber Layer Thickness.

    PubMed

    Biswas, Sayantan; Lin, Chen; Leung, Christopher K S

    2016-09-01

    Analysis of retinal nerve fiber layer (RNFL) abnormalities with optical coherence tomography in eyes with high myopia has been complicated by high rates of false-positive errors. An understanding of whether the application of a myopic normative database can improve the specificity for detection of RNFL abnormalities in eyes with high myopia is relevant. To evaluate the diagnostic performance of a myopic normative database for detection of RNFL abnormalities in eyes with high myopia (spherical equivalent, -6.0 diopters [D] or less). In this cross-sectional study, 180 eyes with high myopia (mean [SD] spherical equivalent, -8.0 [1.8] D) from 180 healthy individuals were included in the myopic normative database. Another 46 eyes with high myopia from healthy individuals (mean [SD] spherical equivalent, -8.1 [1.8] D) and 74 eyes from patients with high myopia and glaucoma (mean [SD] spherical equivalent, -8.3 [1.9] D) were included for evaluation of specificity and sensitivity. The 95th and 99th percentiles of the mean and clock-hour circumpapillary RNFL thicknesses and the individual superpixel thicknesses of the RNFL thickness map measured by spectral-domain optical coherence tomography were calculated from the 180 eyes with high myopia. Participants were recruited from January 2, 2013, to December 30, 2015. The following 6 criteria of RNFL abnormalities were examined: (1) mean circumpapillary RNFL thickness below the lower 95th or (2) the lower 99th percentile; (3) one clock-hour or more for RNFL thickness below the lower 95th or (4) the lower 99th percentile; and (5) twenty contiguous superpixels or more of RNFL thickness in the RNFL thickness map below the lower 95th or (6) the lower 99th percentile. Specificities and sensitivities for detection of RNFL abnormalities. Of the 46 healthy eyes and 74 eyes with glaucoma studied (from 39 men and 38 women), the myopic normative database showed a higher specificity (63.0%-100%) than did the built-in normative database of the optical coherence tomography instrument (8.7%-87.0%) for detection of RNFL abnormalities across all the criteria examined (differences in specificities between 13.0% [95% CI, 1.1%-24.9%; P = .01] and 54.3% [95% CI, 37.8%-70.9%; P < .001]) except for the criterion of mean RNFL thickness below the lower 99th percentile, in which both normative databases had the same specificities (100%) but the myopic normative database exhibited a higher sensitivity (71.6% vs 86.5%; difference in sensitivities, 14.9% [95% CI, 4.6%-25.1%; P = .002]). The application of a myopic normative database improved the specificity without compromising the sensitivity compared with the optical coherence tomography instrument's built-in normative database for detection of RNFL abnormalities in eyes with high myopia. Inclusion of myopic normative databases should be considered in optical coherence tomography instruments.

  2. TOPO-capped silver selenide nanoparticles and their incorporation into polymer nanofibers using electrospinning technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    More, D.S.; Moloto, M.J., E-mail: makwenam@vut.ac.za; Moloto, N.

    Highlights: • Ag{sub 2}Se nanoparticles produced spherical particles with sizes 12 nm (180 °C) and 27 nm (200 °C). • Higher temperature produced increased particle size (∼75 nm) and changed in shape. • Ag{sub 2}Se nanoparticles (0.2–0.6%) added into PVP (35–45%) to yield reduced fiber beading. • Polymer nanofibers electrospun at 11–20 kV produced fiber diameters of 425–461 nm. • Optical properties in the fibers were observed due to the Ag{sub 2}Se nanoparticles loaded. - Abstract: Electrospinning is the most common technique for fabricating polymer fibers as well as nanoparticles embedded polymer fibers. Silver selenide nanoparticles were synthesized using tri-n-octylphosphinemore » (TOP) as solvent and tri-n-octylphosphine oxide (TOPO) as capping environment. Silver selenide was prepared by reacting silver nitrate and selenium with tri-n-octylphosphine (TOP) to form TOP–Ag and TOP–Se solutions. Both absorption and emission spectra signify the formation of nanoparticles as well as the TEM which revealed spherical particles with an average particle size of 22 nm. The polymer, PVP used was prepared at concentrations ranging from (35 to 45 wt%) and the TOPO-capped silver selenide nanoparticles (0.2 and 0.6 wt%) were incorporated into them and electrospun by varying the voltage from 11 to 20 kV. The SEM images of the Ag{sub 2}Se/PVP composite fibers revealed the fibers of diameters with average values of 425 and 461 nm. The X-ray diffraction results show peaks which were identified due to α-Ag{sub 2}Se body centered cubic compound. The sharp peak observed for all the samples at 2θ = 44.5 suggest the presence of Ag in the face centered cubic which can be attributed to higher concentration of silver nitrate used with molar ratio of selenium to silver and the abundance of silver in the silver selenide crystal. Fourier transform infrared spectroscopy, thermogravimetric analysis (TGA) and ultraviolet–visible spectroscopy were used to characterize the structure of the PVP/Ag{sub 2}Se composite fibers.« less

  3. [Measurement of the electric field of the heart in a homogeneous volume conductor].

    PubMed

    Tsukerman, B M; Titomir, L I

    1975-01-01

    The paper describes a technique and some results of experimental measurements of electrical potentials generated by an isolated dog heart in homogeneous conductor, drawing equipotential maps of the field, and calculating the characteristics of the dipole equivalent generator of the heart. The form of potential distribution on a spherical surface around the heart and its ideal orthogonal vectorcardiograms are discussed.

  4. Association of ocular, cardiovascular, morphometric and lifestyle parameters with retinal nerve fibre layer thickness.

    PubMed

    Lamparter, Julia; Schmidtmann, Irene; Schuster, Alexander K; Siouli, Angeliki; Wasielica-Poslednik, Joanna; Mirshahi, Alireza; Höhn, René; Unterrainer, Josef; Wild, Philipp S; Binder, Harald; Lackner, Karl; Beutel, Manfred E; Münzel, Thomas; Pfeiffer, Norbert; Hoffmann, Esther M

    2018-01-01

    Glaucoma is a neurodegenerative disease, leading to thinning of the retinal nerve fibre layer (RNFL). The exact influence of ocular, cardiovascular, morphometric, lifestyle and cognitive factors on RNFL thickness (RNFLT) is unknown and was analysed in a subgroup of the Gutenberg Health Study (GHS). Global peripapillary RNFLT was measured in 3224 eyes of 1973 subjects (49% female) using spectral-domain optical coherence tomography (SD-OCT). The association of age, sex, ocular, cardiovascular, morphometric, lifestyle and cognitive factors on RNFLT was analysed using Pearson correlation coefficient and fitting a linear mixed model. In the univariable analysis highest correlations were found for axial length (r = -0.27), spherical equivalent (r = 0.24), and glaucoma (r = -0.15) (p<0.0001, respectively). Other significant correlations with RNFLT were found for age, sex, intraocular pressure, systemic hypertension and systolic blood pressure, previous eye surgery, cholesterol, homocysteine, history of coronary artery disease, history of myocardial infarction, apnoea, diabetes and alcohol intake, p<0.05, respectively. Body length, body weight, BMI, diastolic blood pressure, blood glucose, HbA1c, history of apoplexy, cognitive function, peripheral artery disease, tinnitus, migraine, nicotine intake, central corneal thickness, and pseudophakia were not significantly correlated with RNFLT. The regression model revealed a significant relationship between RNFLT and age in decades (p<0.02), spherical equivalent (p<0.0001), axial length (p<0.0001), glaucoma (p<0.0001), tinnitus (p = 0.04), apnoea (p = 0.047), homocysteine (p = 0.05) and alcohol intake >10g/d for women and >20g/d for men (p = 0.02). Glaucoma, apnoea, higher homocysteine, higher alcohol intake and higher axial length as well as age were related to decreased RNFLT while higher spherical equivalent or history for tinnitus were related to thicker RNFL. RNFLT is related to age, ocular parameters and lifestyle factors. Considering these parameters in normative databases could improve the evaluation of peripapillary RNFLT. It is necessary to evaluate if a reduction of alcohol intake as well as the therapy of apnea or high homocysteine levels could positively influence RNFLT.

  5. Exploring the Behavior and Metabolic Transformations of SeNPs in Exposed Lactic Acid Bacteria. Effect of Nanoparticles Coating Agent

    PubMed Central

    Palomo-Siguero, Maria; Madrid, Yolanda

    2017-01-01

    The behavior and transformation of selenium nanoparticles (SeNPs) in living systems such as microorganisms is largely unknown. To address this knowledge gap, we examined the effect of three types of SeNP suspensions toward Lactobacillus delbrueckii subsp. bulgaricus LB-12 using a variety of techniques. SeNPs were synthesized using three types of coating agents (chitosan (CS-SeNPs), hydroxyethyl cellulose (HEC-SeNPs) and a non-ionic surfactant, surfynol (ethoxylated-SeNPs)). Morphologies of SeNPs were all spherical. Transmission electron microscopy (TEM) was used to locate SeNPs in the bacteria. High performance liquid chromatography (HPLC) on line coupled to inductively coupled plasma mass spectrometry (ICP-MS) was applied to evaluate SeNP transformation by bacteria. Finally, flow cytometry employing the live/dead test and optical density measurements at 600 nm (OD600) were used for evaluating the percentages of bacteria viability when supplementing with SeNPs. Negligible damage was detected by flow cytometry when bacteria were exposed to HEC-SeNPs or CS-SeNPs at a level of 10 μg Se mL−1. In contrast, ethoxylated-SeNPs were found to be the most harmful nanoparticles toward bacteria. CS-SeNPs passed through the membrane without causing damage. Once inside, SeNPs were metabolically transformed to organic selenium compounds. Results evidenced the importance of capping agents when establishing the true behavior of NPs. PMID:28783048

  6. Low-frequency dielectric spectra of low-resistivity GaSe crystals (in Ukrainian)

    NASA Astrophysics Data System (ADS)

    Stakhira, J.; Fl'Unt, O.; Fiyala, Ya.

    The low-frequency dielectric response of low-resistivity GaSe layered crystal along the c-axis has been investigated at liquid nitrogen temperatures. The normalized spectra (activation energies from frequency shift is 0.19 eV) have been treated analytically employing equivalent circuits. It is shown that experimental data cannot be obtained with the circuit containing only ideal capacitors and resistors. At the same time, the equivalent circuit containing dispersive capacitors characterized by the power law dependence on frequency C^*=B(jω)^{n-1}, where ω is radian frequency, 0< n< 1, gives a good agreement with experimental data. This means that measured response of low-resistivity GaSe crystals follows the ``universal" power law of dielectric response χ^*˜(jω)^{n-1}, but not the Debye one. The nature of the ``universal" power law is explained by many-body interactions between localized charge carriers.

  7. Classification of Stellar Orbits in Axisymmetric Galaxies

    NASA Astrophysics Data System (ADS)

    Li, Baile; Holley-Bockelmann, Kelly; Khan, Fazeel Mahmood

    2015-09-01

    It is known that two supermassive black holes (SMBHs) cannot merge in a spherical galaxy within a Hubble time; an emerging picture is that galaxy geometry, rotation, and large potential perturbations may usher the SMBH binary through the critical three-body scattering phase and ultimately drive the SMBH to coalesce. We explore the orbital content within an N-body model of a mildly flattened, non-rotating, SMBH-embedded elliptical galaxy. When used as the foundation for a study on the SMBH binary coalescence, the black holes bypassed the binary stalling often seen within spherical galaxies and merged on gigayear timescales. Using both frequency-mapping and angular momentum criteria, we identify a wealth of resonant orbits in the axisymmetric model, including saucers, that are absent from an otherwise identical spherical system and that can potentially interact with the binary. We quantified the set of orbits that could be scattered by the SMBH binary, and found that the axisymmetric model contained nearly six times the number of these potential loss cone orbits compared to our equivalent spherical model. In this flattened model, the mass of these orbits is more than three times that of the SMBH, which is consistent with what the SMBH binary needs to scatter to transition into the gravitational wave regime.

  8. CLASSIFICATION OF STELLAR ORBITS IN AXISYMMETRIC GALAXIES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Baile; Holley-Bockelmann, Kelly; Khan, Fazeel Mahmood, E-mail: baile.li@vanderbilt.edu, E-mail: k.holley@vanderbilt.edu, E-mail: khanfazeel.ist@gmail.com

    2015-09-20

    It is known that two supermassive black holes (SMBHs) cannot merge in a spherical galaxy within a Hubble time; an emerging picture is that galaxy geometry, rotation, and large potential perturbations may usher the SMBH binary through the critical three-body scattering phase and ultimately drive the SMBH to coalesce. We explore the orbital content within an N-body model of a mildly flattened, non-rotating, SMBH-embedded elliptical galaxy. When used as the foundation for a study on the SMBH binary coalescence, the black holes bypassed the binary stalling often seen within spherical galaxies and merged on gigayear timescales. Using both frequency-mapping andmore » angular momentum criteria, we identify a wealth of resonant orbits in the axisymmetric model, including saucers, that are absent from an otherwise identical spherical system and that can potentially interact with the binary. We quantified the set of orbits that could be scattered by the SMBH binary, and found that the axisymmetric model contained nearly six times the number of these potential loss cone orbits compared to our equivalent spherical model. In this flattened model, the mass of these orbits is more than three times that of the SMBH, which is consistent with what the SMBH binary needs to scatter to transition into the gravitational wave regime.« less

  9. A subchronic toxicity study of elemental Nano-Se in Sprague-Dawley rats.

    PubMed

    Jia, X; Li, N; Chen, J

    2005-03-11

    The subchronic toxicity of Nano-Se was compared with selenite and high-selenium protein in rats. Groups of Sprague-Dawley rats (12 males and 12 females per group) were fed diets containing Nano-Se, selenite and high-selenium protein at concentrations of 0, 2, 3, 4 and 5 ppm Se, respectively, for 13 weeks. Clinical observations were made and body weight and food consumption were recorded weekly. At the end of the study, the rats were subjected to a full necropsy, blood samples were collected for hematology and clinical chemistry determination. Histopathological examination was performed on selected tissues. At the two higher doses (4 and 5 ppm Se), significant abnormal changes were found in body weight, hematology, clinical chemistry, relative organ weights and histopathology parameters. However, the toxicity was more pronounced in the selenite and high-selenium protein groups than the Nano-Se group. At the dose of 3 ppm Se, significant growth inhibition and degeneration of liver cells were found in the selenite and high-selenium protein groups. No changes attributable to administration of Nano-Se at the dose of 3 ppm Se were found. Taken together, the no-observed-adverse-effect level (NOAEL) of Nano-Se in male and female rats was considered to be 3 ppm Se, equivalent to 0.22 mg/kg bw/day for males and 0.33 mg/kg bw/day for females. On the other hand, the NOAELs of selenite and high-selenium protein in males and females were considered to be 2 ppm Se, equivalent to 0.14 mg/kg bw/day for males and 0.20 mg/kg bw/day for females. In addition, studies have shown that Nano-Se has a similar bioavailability in rat, and much less acute toxicity in mice compared with selenite. In conclusion, Nano-Se is less toxic than selenite and high-selenium protein in the 13-week rat study.

  10. Family of spherical models with special gravitational properties

    NASA Astrophysics Data System (ADS)

    Kondratyev, B. P.

    2015-03-01

    A new method for studying the structural and gravitational properties of spherical systems based on an analysis of the ratio of the potentials for their subsystems and shells has been developed. It has been proven for the first time that the gravitational virial Z( r) of the subsystem without allowance for the influence of the outer shell is equal to twice the work done to disperce the subsystem's matter to infinity. A new class of spherical models has been constructed in which: (1) the ratio of the contribution to the potential at point r from the spherical subsystem to the contribution from the outer shell does not depend on radius and is equal to a constant γ; (2) the ratio of the gravitational energy W( r) to Z( r) for the spherical subsystem does not depend on r; and (3) the models are described by a power law of the density ρ = cr - κ and potential . Expressions for the gravitational energy W( r) and virial Z( r) have been found for the subsystem. The limiting case of ρ( r) ∝ r -5/2, where the subsystem's potential at any sampling point is exactly equal to the potential from the outer shell and Z( r) is equivalent to its gravitational energy W( r), is considered in detail. The results supplement the classical potential theory. The question about the application of the models to the superdense nuclear star cluster in the center of the Milky Way is discussed.

  11. Clinical outcomes of small incision lenticule extraction versus femtosecond laser-assisted LASIK for myopia: a Meta-analysis

    PubMed Central

    Yan, Huan; Gong, Li-Yan; Huang, Wei; Peng, Yan-Li

    2017-01-01

    AIM To evaluate the possible differences in visual quality between small incision lenticule extraction (SMILE) and femtosecond laser in situ keratomileusis (FS-LASIK) for myopia. METHODS A Meta-analysis was performed. Patients were from previously reported comparative studies treated with SMILE versus FS-LASIK. The PubMed, EMBASE, Cochrane, Web of Science and Chinese databases (i.e. WANFANG and CNKI) were searched in Nov. of 2016 using RevMan 5.1 version software. The differences in visual acuity, aberration and biomechanical effects within six months postoperatively were showed. Twenty-seven studies including 4223 eyes were included. RESULTS No significant differences were observed between SMILE and FS-LASIK in terms of the proportion of eyes that lost one or more lines of corrected distance visual acuity after surgery (P=0.14), the proportion of eyes achieving an uncorrected distance visual acuity of 20/20 or better (P=0.43), the final refractive spherical equivalent (P=0.89), the refractive spherical equivalent within ±1.00 diopter of the target values (P=0.80), vertical coma (P=0.45) and horizontal coma (P=0.06). Compared with the FS-LASIK group, total higher-order aberration (P<0.001) and spherical aberration (P<0.001) were higher and the decrease in corneal hysteresis (P=0.0005) and corneal resistance factor (P=0.02) were lower in the SMILE group. CONCLUSION SMILE and FS-LASIK are comparable in efficacy, safety and predictability for correcting myopia. However, the aberration in the SMILE group is superior to that in the FS-LASIK group, and the loss of biomechanical effects may occur less frequently after SMILE than after FS-LASIK. PMID:28944205

  12. Refraction and the axial length of the eyeball in patients with the optic disc drusen.

    PubMed

    Obuchowska, Iwona; Mariak, Zofia

    2009-01-01

    The aim of the study was to demonstrate the relationship between the optic disc drusen (ODD) and the axial length of the eyeball as well as refractive error. We examined prospectively 40 patients with ODD, 18 men and 22 women, age range from 34 to 69 years. All subjects underwent full ophthalmic examination, visual field testing and color-coded duplex sonography of the ocular vessels. Refraction was determined with an autorefractometer (Topcon RM-8000B) and further refined subjectively. Spherical equivalent refraction was calculated as the spherical dioptre plus one half of the cylindrical dioptre. Axial lengths were measured with a Sonomed ultrasound scanner model E-Z Scan AB5500. Clinical signs were observed in 65% of the eyes with drusen, among them, 38% had symptoms of visual acuity loss and all had visual fields defects. There were 21 eyes (18 eyes with and 3 without drusen), with a recorded refractive error. Significant differences in hyperopia were observed between the eyes with and without drusen (p = 0.048). The rate of occurrence of myopia did not differ significantly between affected and unaffected eyes (p = 0.06). The mean spherical equivalent refraction and axial dimensions of the eye differed significantly among the groups of eyes with and without drusen (p < 0.05). Significant differences in mean values of peak-systolic and end-diastolic velocities (p < 0.001) as well as in the resistivity index (p = 0.047) were observed between eyes with and without drusen. The optic disc drusen are often associated with shorter and hyperopic eyes. This anatomical conditions and vascular factors may contribute to pathogenesis of drusen.

  13. Aspheric photorefractive keratectomy for myopia and myopic astigmatism with the SCHWIND AMARIS laser: 2 years postoperative outcomes

    PubMed Central

    Aslanides, Ioannis M.; Padroni, Sara; Arba-Mosquera, Samuel

    2012-01-01

    Purpose To evaluate mid-term refractive outcomes and higher order aberrations of aspheric PRK for low, moderate and high myopia and myopic astigmatism with the AMARIS excimer laser system (SCHWIND eye-tech-solutions GmbH, Kleinostheim, Germany). Methods This prospective longitudinal study evaluated 80 eyes of 40 subjects who underwent aspheric PRK. Manifest refractive spherical equivalent (MRSE) of up to −10.00 diopters (D) at the spectacle plane with cylinder up to 3.25 was treated. Refractive outcomes and corneal wavefront data (6 mm pupil to the 7th Zernike order) were evaluated out to 2 years postoperatively. Statistical significance was indicated by P < 0.05. Results The mean manifest spherical equivalent refraction (MRSE) was −4.77 ± 2.45 (range, −10.00 D to −0.75 D) preoperatively and −0.12 ± 0.35 D (range, −1.87 D to +0.75 D) postoperatively (P < 0.0001). Postoperatively, 91% (73/80) of eyes had an MRSE within ±0.50 D of the attempted. No eyes lost one or more lines of corrected distance visual acuity (CDVA) and CDVA increased by one or more lines in 26% (21/80) of eyes. Corneal trefoil and corneal higher order aberration root mean square did not statistically change postoperatively compared to preoperatively (P > 0.05, both cases). There was a statistical increase in postoperative coma (+0.12 μm) and spherical aberration (+0.14 μm) compared to preoperatively (P < 0.001, both cases). Conclusion Aspheric PRK provides excellent visual and refractive outcomes with induction in individual corneal aberrations but not overall corneal aberrations.

  14. Organ shielding and doses in Low-Earth orbit calculated for spherical and anthropomorphic phantoms

    NASA Astrophysics Data System (ADS)

    Matthiä, Daniel; Berger, Thomas; Reitz, Günther

    2013-08-01

    Humans in space are exposed to elevated levels of radiation compared to ground. Different sources contribute to the total exposure with galactic cosmic rays being the most important component. The application of numerical and anthropomorphic phantoms in simulations allows the estimation of dose rates from galactic cosmic rays in individual organs and whole body quantities such as the effective dose. The male and female reference phantoms defined by the International Commission on Radiological Protection and the hermaphrodite numerical RANDO phantom are voxel implementations of anthropomorphic phantoms and contain all organs relevant for radiation risk assessment. These anthropomorphic phantoms together with a spherical water phantom were used in this work to translate the mean shielding of organs in the different anthropomorphic voxel phantoms into positions in the spherical phantom. This relation allows using a water sphere as surrogate for the anthropomorphic phantoms in both simulations and measurements. Moreover, using spherical phantoms in the calculation of radiation exposure offers great advantages over anthropomorphic phantoms in terms of computational time. In this work, the mean shielding of organs in the different voxel phantoms exposed to isotropic irradiation is presented as well as the corresponding depth in a water sphere. Dose rates for Low-Earth orbit from galactic cosmic rays during solar minimum conditions were calculated using the different phantoms and are compared to the results for a spherical water phantom in combination with the mean organ shielding. For the spherical water phantom the impact of different aluminium shielding between 1 g/cm2 and 100 g/cm2 was calculated. The dose equivalent rates were used to estimate the effective dose rate.

  15. Biocompatibility selenium nanoparticles with an intrinsic oxidase-like activity

    NASA Astrophysics Data System (ADS)

    Guo, Leilei; Huang, Kaixun; Liu, Hongmei

    2016-03-01

    Selenium nanoparticles (SeNPs) are considered to be the new selenium supplement forms with high biological activity and low toxicity; however, the molecular mechanism by which SeNPs exert the biological function is unclear. Here, we reported that biocompatibility SeNPs possessed intrinsic oxidase-like activity. Using Na2SeO3 as a precursor and glutathione as a reductant, biocompatibility SeNPs were synthesized by the wet chemical reduction method in the presence of bovine serum albumin (BSA). The results of structure characterization revealed that synthesized SeNPs were amorphous red elementary selenium with spherical morphology, and ranged in size from 25 to 70 nm size with a narrow distribution (41.4 ± 6.7 nm). The oxidase-like activity of the as-synthesized SeNPs was tested with 3,3',5,5'-tetramethylbenzidine (TMB) as a substrate. The results indicated that SeNPs could catalyze the oxidization of TMB by dissolved oxygen. These SeNPs showed an optimum catalytic activity at pH 4 and 30 °C, and the oxidase-like activity was higher as the concentration of SeNPs increased and the size of SeNPs decreased. The Michaelis constant ( K m) values and maximal reaction velocity ( V max) of the SeNPs for TMB oxidation were 0.0083 mol/L and 3.042 μmol/L min, respectively.

  16. Bacterial reduction of selenium in coal mine tailings pond sediment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siddique, T.; Arocena, J.M.; Thring, R.W.

    2007-05-15

    Sediment from a storage facility for coal tailings solids was assessed for its capacity to reduce selenium (Se) by native bacterial community. One Se{sup 6+}-reducing bacterium Enterobacter hormaechei (Tar11) and four Se{sup 4+}-reducing bacteria, Klebsiella pneumoniae (Tar1), Pseudomonasfluorescens (Tar3), Stenotrophomonas maltophilia (Tar6), and Enterobacter amnigenus (Tar8) were isolated from the sediment. Enterobacter horinaechei removed 96% of the added Se{sup 6+} (0.92 mg L{sup -1} from the effluents when Se6+ was determined after 5 d of incubation. Analysis of the red precipitates showed that Se{sup 6+} reduction resulted in the formation of spherical particles ({lt}1.0 {mu} m) of Se 0 asmore » observed under scanning electron microscope (SEM) and confirmed by EDAX. Selenium speciation was performed to examine the fate of the added Se{sup 6+} in the sediment with or without addition of Enterobacter hormaechei cells. More than 99% of the added Se{sup 6+} (about 2.5 mg L{sup -1}) was transformed in the nonsterilized sediment (without Enterobacter hormaechei cells) as well as in the sterilized (heat-killed) sediment (with Enterobacter hormaechei cells). The results of this study suggest that the lagoon sediments at the mine site harbor Se{sup 6+}- and Se{sup 4+} -reducing bacteria and may be important sinks for soluble Se (Se{sup 6+} and Se{sup 4+}). Enterobacter hormaechei isolated from metal-contaminated sediment may have potential application in removing Se from industrial effluents.« less

  17. Absorption and scattering by fractal aggregates and by their equivalent coated spheres

    NASA Astrophysics Data System (ADS)

    Kandilian, Razmig; Heng, Ri-Liang; Pilon, Laurent

    2015-01-01

    This paper demonstrates that the absorption and scattering cross-sections and the asymmetry factor of randomly oriented fractal aggregates of spherical monomers can be rapidly estimated as those of coated spheres with equivalent volume and average projected area. This was established for fractal aggregates with fractal dimension ranging from 2.0 to 3.0 and composed of up to 1000 monodisperse or polydisperse monomers with a wide range of size parameter and relative complex index of refraction. This equivalent coated sphere approximation was able to capture the effects of both multiple scattering and shading among constituent monomers on the integral radiation characteristics of the aggregates. It was shown to be superior to the Rayleigh-Debye-Gans approximation and to the equivalent coated sphere approximation proposed by Latimer. However, the scattering matrix element ratios of equivalent coated spheres featured large angular oscillations caused by internal reflection in the coating which were not observed in those of the corresponding fractal aggregates. Finally, the scattering phase function and the scattering matrix elements of aggregates with large monomer size parameter were found to have unique features that could be used in remote sensing applications.

  18. Clay-clast aggregates: A new textural evidence for seismic fault sliding?

    NASA Astrophysics Data System (ADS)

    Boutareaud, Sébastien; Calugaru, Dan-Gabriel; Han, Raehee; Fabbri, Olivier; Mizoguchi, Kazuo; Tsutsumi, Akito; Shimamoto, Toshihiko

    2008-03-01

    To determine the processes responsible for slip-weakening in clayey gouge zones, rotary-shear experiments were conducted at seismic slip rates (equivalent to 0.9 and 1.3 m/s) at 0.6 MPa normal stress on a natural clayey gouge for saturated and non-saturated initial conditions. The mechanical behavior of the simulated faults shows a reproducible slip-weakening behavior, whatever initial moisture conditions. Examination of gouge obtained at the residual friction stage in saturated and non-saturated initial conditions allows the definition of two types of microstructures: a foliated type reflecting strain localization, and a non-foliated type composed of spherical aggregates. Friction experiments demonstrate that liquid-vapor transition of water within gouge due to frictional heating has a high capacity to explain the formation of spherical aggregates in the first meters of displacement. This result suggests that the occurrence of spherical aggregates in natural clayey fault gouges can constitute a new textural evidence for shallow depth pore water phase transition at seismic slip velocity and consequently for past seismic fault sliding.

  19. Porous poly-ether ether ketone (PEEK) manufactured by a novel powder route using near-spherical salt bead porogens: characterisation and mechanical properties.

    PubMed

    Siddiq, Abdur R; Kennedy, Andrew R

    2015-02-01

    Porous PEEK structures with approximately 85% open porosity have been made using PEEK-OPTIMA® powder and a particulate leaching technique using porous, near-spherical, sodium chloride beads. A novel manufacturing approach is presented and compared with a traditional dry mixing method. Irrespective of the method used, the use of near-spherical beads with a fairly narrow size range results in uniform pore structures. However the integration, by tapping, of fine PEEK into a pre-existing network salt beads, followed by compaction and "sintering", produces porous structures with excellent repeatability and homogeneity of density; more uniform pore and strut sizes; an improved and predictable level of connectivity via the formation of "windows" between the cells; faster salt removal rates and lower levels of residual salt. Although tapped samples show a compressive yield stress >1 MPa and stiffness >30 MPa for samples with 84% porosity, the presence of windows in the cell walls means that tapped structures show lower strengths and lower stiffnesses than equivalent structures made by mixing. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Aspherical bubble dynamics and oscillation times

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Godwin, R.P.; Chapyak, E.J.; Noack, J.

    1999-03-01

    The cavitation bubbles common in laser medicine are rarely perfectly spherical and are often located near tissue boundaries, in vessels, etc., which introduce aspherical dynamics. Here, novel features of aspherical bubble dynamics are explored. Time-resolved experimental photographs and simulations of large aspect ratio (length:diameter {approximately}20) cylindrical bubble dynamics are presented. The experiments and calculations exhibit similar dynamics. A small high-pressure cylindrical bubble initially expands radially with hardly any axial motion. Then, after reaching its maximum volume, a cylindrical bubble collapses along its long axis with relatively little radial motion. The growth-collapse period of these very aspherical bubbles differs only sightlymore » from twice the Rayleigh collapse time for a spherical bubble with an equivalent maximum volume. This fact justifies using the temporal interval between the acoustic signals emitted upon bubble creation and collapse to estimate the maximum bubble volume. As a result, hydrophone measurements can provide an estimate of the bubble energy even for aspherical bubbles. The prolongation of the oscillation period of bubbles near solid boundaries relative to that of isolated spherical bubbles is also discussed.« less

  1. A new method for gravity field recovery based on frequency analysis of spherical harmonics

    NASA Astrophysics Data System (ADS)

    Cai, Lin; Zhou, Zebing

    2017-04-01

    All existing methods for gravity field recovery are mostly based on the space-wise and time-wise approach, whose core processes are constructing the observation equations and solving them by the least square method. It's should be pointed that the least square method means the approximation. On the other hand, we can directly and precisely obtain the coefficients of harmonics by computing the Fast Fourier Transform (FFT) when we do 1-D data (time series) analysis. So the question whether we directly and precisely obtain the coefficients of spherical harmonic by computing 2-D FFT of measurements of satellite gravity mission is of great significance, since this may guide us to a new understanding of the signal components of gravity field and make us determine it quickly by taking advantage of FFT. Like the 1-D data analysis, the 2-D FFT of measurements of satellite can be computed rapidly. If we can determine the relationship between spherical harmonics and 2-D Fourier frequencies and the transfer function from measurements to spherical coefficients, the question mentioned above can be solved. So the objective of this research project is to establish a new method based on frequency analysis of spherical harmonic, which directly compute the confidents of spherical harmonic of gravity field, which is differ from recovery by least squares. There is a one to one correspondence between frequency spectrum and the time series in 1-D FFT. The 2-D FFT has a similar relationship to 1-D FFT. Owing to the fact that any degree or order (higher than one) of spherical function has multi frequencies and these frequencies may be aliased. Fortunately, the elements and ratio of these frequencies of spherical function can be determined, and we can compute the coefficients of spherical function from 2-D FFT. This relationship can be written as equations and equivalent to a matrix, which is solid and can be derived in advance. Until now the relationship has be determined. Some preliminary results, which only compute lower degree spherical harmonics, indicates that the difference between the input (EGM2008) and output (coefficients from recovery) is smaller than 5E-17, while the minimal precision of computer software (Matlab) is 2.2204E-16.

  2. Tunable-Bandwidth Filter System

    NASA Technical Reports Server (NTRS)

    Bailey, John W.

    2004-01-01

    A tunable-bandwidth filter system (TBFS), now undergoing development, is intended to be part of a remote sensing multispectral imaging system that will operate in the visible and near infrared spectral region (wavelengths from 400 to 900 nm). Attributes of the TBFS include rapid tunability of the pass band over a wide wavelength range and high transmission efficiency. The TBFS is based on a unique integration of two pairs of broadband Raman reflection holographic filters with two rotating spherical lenses. In experiments, a prototype of the TBFS, was shown to be capable of spectral sampling of images in the visible range over a 200 nm spectral range with a spectral resolution of 30 nm. The figure depicts the optical layout of a prototype of the TBFS as part of a laboratory multispectral imaging system for the spectral sampling of color test images in two orthogonal polarizations. Each pair of broadband Raman reflection holographic filters is mounted at an equatorial plane between two halves of a spherical lens. The two filters in each pair are characterized by steep spectral slopes (equivalently, narrow spectral edges), no ripple or side lobes in their pass bands, and a few nanometers of non-overlapping wavelength range between their pass bands. Each spherical lens and thus the filter pair within it is rotated in order to rapidly tune its pass band. The rotations of are effected by electronically controlled, programmable, high-precision rotation stages. The rotations are coordinated by electronic circuits operating under overall supervision of a personal computer in order to obtain the desired variation of the overall pass bands with time. Embedding the filters inside the spherical lenses increases the range of the hologram incidence angles, making it possible to continuously tune the pass and stop bands of the filters over a wider wavelength range. In addition, each spherical lens also serves as part of the imaging optics: The telephoto lens focuses incoming light to a field stop that is also a focal point of each spherical lens. A correcting lens in front of the field stop compensates for the spherical aberration of the spherical lenses. The front surface of each spherical lens collimates the light coming from the field stop. After the collimated light passes through the filter in the spherical lens, the rear surface of the lens focuses the light onto a charge-coupled-device image detector.

  3. Tunable-Bandwidth Filter System

    NASA Technical Reports Server (NTRS)

    Aye, Tin; Yu, Kevin; Dimov, Fedor; Savant, Gajendra

    2006-01-01

    A tunable-bandwidth filter system (TBFS), now undergoing development, is intended to be part of a remote-sensing multispectral imaging system that will operate in the visible and near infrared spectral region (wavelengths from 400 to 900 nm). Attributes of the TBFS include rapid tunability of the pass band over a wide wavelength range and high transmission efficiency. The TBFS is based on a unique integration of two pairs of broadband Raman reflection holographic filters with two rotating spherical lenses. In experiments, a prototype of the TBFS was shown to be capable of spectral sampling of images in the visible range over a 200-nm spectral range with a spectral resolution of .30 nm. The figure depicts the optical layout of a prototype of the TBFS as part of a laboratory multispectral imaging system for the spectral sampling of color test images in two orthogonal polarizations. Each pair of broadband Raman reflection holographic filters is mounted at an equatorial plane between two halves of a spherical lens. The two filters in each pair are characterized by steep spectral slopes (equivalently, narrow spectral edges), no ripple or side lobes in their pass bands, and a few nanometers of non-overlapping wavelength range between their pass bands. Each spherical lens and thus the filter pair within it is rotated in order to rapidly tune its pass band. The rotations of the lenses are effected by electronically controlled, programmable, high-precision rotation stages. The rotations are coordinated by electronic circuits operating under overall supervision of a personal computer in order to obtain the desired variation of the overall pass bands with time. Embedding the filters inside the spherical lenses increases the range of the hologram incidence angles, making it possible to continuously tune the pass and stop bands of the filters over a wider wavelength range. In addition, each spherical lens also serves as part of the imaging optics: The telephoto lens focuses incoming light to a field stop that is also a focal point of each spherical lens. A correcting lens in front of the field stop compensates for the spherical aberration of the spherical lenses. The front surface of each spherical lens collimates the light coming from the field stop. After the collimated light passes through the filter in the spherical lens, the rear surface of the lens focuses the light onto a charge-coupled-device image detector.

  4. Effects of snow grain shape on climate simulations: sensitivity tests with the Norwegian Earth System Model

    NASA Astrophysics Data System (ADS)

    Räisänen, Petri; Makkonen, Risto; Kirkevåg, Alf; Debernard, Jens B.

    2017-12-01

    Snow consists of non-spherical grains of various shapes and sizes. Still, in radiative transfer calculations, snow grains are often treated as spherical. This also applies to the computation of snow albedo in the Snow, Ice, and Aerosol Radiation (SNICAR) model and in the Los Alamos sea ice model, version 4 (CICE4), both of which are employed in the Community Earth System Model and in the Norwegian Earth System Model (NorESM). In this study, we evaluate the effect of snow grain shape on climate simulated by NorESM in a slab ocean configuration of the model. An experiment with spherical snow grains (SPH) is compared with another (NONSPH) in which the snow shortwave single-scattering properties are based on a combination of three non-spherical snow grain shapes optimized using measurements of angular scattering by blowing snow. The key difference between these treatments is that the asymmetry parameter is smaller in the non-spherical case (0.77-0.78 in the visible region) than in the spherical case ( ≈ 0.89). Therefore, for the same effective snow grain size (or equivalently, the same specific projected area), the snow broadband albedo is higher when assuming non-spherical rather than spherical snow grains, typically by 0.02-0.03. Considering the spherical case as the baseline, this results in an instantaneous negative change in net shortwave radiation with a global-mean top-of-the-model value of ca. -0.22 W m-2. Although this global-mean radiative effect is rather modest, the impacts on the climate simulated by NorESM are substantial. The global annual-mean 2 m air temperature in NONSPH is 1.17 K lower than in SPH, with substantially larger differences at high latitudes. The climatic response is amplified by strong snow and sea ice feedbacks. It is further demonstrated that the effect of snow grain shape could be largely offset by adjusting the snow grain size. When assuming non-spherical snow grains with the parameterized grain size increased by ca. 70 %, the climatic differences to the SPH experiment become very small. Finally, the impact of assumed snow grain shape on the radiative effects of absorbing aerosols in snow is discussed.

  5. Evidence for phase change memory behavior in In2(SexTe1-x)3 thin films

    NASA Astrophysics Data System (ADS)

    Matheswaran, P.; Sathyamoorthy, R.; Asokan, K.

    2012-08-01

    Crystalline In2(Se0.5Te0.5)3 thin films are prepared by thermal evaporation and subsequently annealed at 300°C in Ar atmosphere. SEM image of the crystalline sample shows spherical nature of constituents, distributed uniformly throughout the surface. Island structure of the surface is clearly visible after switching. Elemental composition of the sample remains unchanged even after switching. Temperature dependent I-V analysis shows stoichiometric phase change at 80°C [from In2(Se0.5Te0.5)3 to In2Te3 and In2Se3 phase], where current switches three orders of magnitude higher than that in lower temperature. Further rise in temperature results increase in current only after switching, where threshold voltage remains constant.

  6. Deep circulations under simple classes of stratification

    NASA Technical Reports Server (NTRS)

    Salby, Murry L.

    1989-01-01

    Deep circulations where the motion field is vertically aligned over one or more scale heights are studied under barotropic and equivalent barotropic stratifications. The study uses two-dimensional equations reduced from the three-dimensional primitive equations in spherical geometry. A mapping is established between the full primitive equations and general shallow water behavior and the correspondence between variables describing deep atmospheric motion and those of shallow water behavior is established.

  7. Air Blast Calculations

    DTIC Science & Technology

    2013-07-01

    composition C-4 (C4), a polymer-bonded explosive (PBXN-109), and nitromethane (NM). Each charge diameter (CD) is assumed to be 17.46 cm (equivalent to a 10-lb... explosive detonates, the rapid expansion of reaction gases generates a shock wave that propagates into the surrounding medium. The pressure history at a...spherical explosive charge suspended in air. A comparison of the results obtained using CTH are made to ones generated using the Friedlander

  8. Antimicrobial activity of spherical silver nanoparticles prepared using a biocompatible macromolecular capping agent: evidence for induction of a greatly prolonged bacterial lag phase

    USDA-ARS?s Scientific Manuscript database

    We have evaluated the antimicrobial properties of Ag-based nanoparticles (Np) using two solid platform-based bioassays and found that 10-20 uL of 0.3-3 uM keratin-based Nps (depending on the starting bacteria concentration = CI) completely inhibited the growth of an equivalent volume of ca. 1,000 to...

  9. Structure, thermodynamic properties, and phase diagrams of few colloids confined in a spherical pore.

    PubMed

    Paganini, Iván E; Pastorino, Claudio; Urrutia, Ignacio

    2015-06-28

    We study a system of few colloids confined in a small spherical cavity with event driven molecular dynamics simulations in the canonical ensemble. The colloidal particles interact through a short range square-well potential that takes into account the basic elements of attraction and excluded-volume repulsion of the interaction among colloids. We analyze the structural and thermodynamic properties of this few-body confined system in the framework of inhomogeneous fluids theory. Pair correlation function and density profile are used to determine the structure and the spatial characteristics of the system. Pressure on the walls, internal energy, and surface quantities such as surface tension and adsorption are also analyzed for a wide range of densities and temperatures. We have characterized systems from 2 to 6 confined particles, identifying distinctive qualitative behavior over the thermodynamic plane T - ρ, in a few-particle equivalent to phase diagrams of macroscopic systems. Applying the extended law of corresponding states, the square well interaction is mapped to the Asakura-Oosawa model for colloid-polymer mixtures. We link explicitly the temperature of the confined square-well fluid to the equivalent packing fraction of polymers in the Asakura-Oosawa model. Using this approach, we study the confined system of few colloids in a colloid-polymer mixture.

  10. Relationship between lenticular power and refractive error in children with hyperopia.

    PubMed

    Tomomatsu, Takeshi; Kono, Shinjiro; Arimura, Shogo; Tomomatsu, Yoko; Matsumura, Takehiro; Takihara, Yuji; Inatani, Masaru; Takamura, Yoshihiro

    2013-01-01

    To evaluate the contribution of axial length, and lenticular and corneal power to the spherical equivalent refractive error in children with hyperopia between 3 and 13 years of age, using noncontact optical biometry. There were 62 children between 3 and 13 years of age with hyperopia (+2 diopters [D] or more) who underwent automated refraction measurement with cycloplegia, to measure spherical equivalent refractive error and corneal power. Axial length was measured using an optic biometer that does not require contact with the cornea. The refractive power of the lens was calculated using the Sanders-Retzlaff-Kraff formula. Single regression analysis was used to evaluate the correlation among the optical parameters. There was a significant positive correlation between age and axial length (P = 0.0014); however, the degree of hyperopia did not decrease with aging (P = 0.59). There was a significant negative correlation between age and the refractive power of the lens (P = 0.0001) but not that of the cornea (P = 0.43). A significant negative correlation was observed between the degree of hyperopia and lenticular power (P < 0.0001). Although this study is small scale and cross sectional, the analysis, using noncontact biometry, showed that lenticular power was negatively correlated with refractive error and age, indicating that lower lens power may contribute to the degree of hyperopia.

  11. Interocular symmetry in macular choroidal thickness in children.

    PubMed

    Al-Haddad, Christiane; El Chaar, Lama; Antonios, Rafic; El-Dairi, Mays; Noureddin, Baha'

    2014-01-01

    Objective. To report interocular differences in choroidal thickness in children using spectral domain optical coherence tomography (SD-OCT) and correlate findings with biometric data. Methods. This observational cross-sectional study included 91 (182 eyes) healthy children aged 6 to 17 years with no ocular abnormality except refractive error. After a comprehensive eye exam and axial length measurement, high definition macular scans were performed using SD-OCT. Two observers manually measured the choroidal thickness at the foveal center and at 1500 µm nasally, temporally, inferiorly, and superiorly. Interocular differences were computed; correlations with age, gender, refractive error, and axial length were performed. Results. Mean age was 10.40 ± 3.17 years; mean axial length and refractive error values were similar between fellow eyes. There was excellent correlation between the two observers' measurements. No significant interocular differences were observed at any location. There was only a trend for right eyes to have higher values in all thicknesses, except the superior thickness. Most of the choroidal thickness measurements correlated positively with spherical equivalent but not with axial length, age, or gender. Conclusion. Choroidal thickness measurements in children as performed using SD-OCT revealed a high level of interobserver agreement and consistent interocular symmetry. Values correlated positively with spherical equivalent refraction.

  12. Structure, thermodynamic properties, and phase diagrams of few colloids confined in a spherical pore

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paganini, Iván E.; Pastorino, Claudio, E-mail: pastor@cnea.gov.ar; Urrutia, Ignacio, E-mail: iurrutia@cnea.gov.ar

    2015-06-28

    We study a system of few colloids confined in a small spherical cavity with event driven molecular dynamics simulations in the canonical ensemble. The colloidal particles interact through a short range square-well potential that takes into account the basic elements of attraction and excluded-volume repulsion of the interaction among colloids. We analyze the structural and thermodynamic properties of this few-body confined system in the framework of inhomogeneous fluids theory. Pair correlation function and density profile are used to determine the structure and the spatial characteristics of the system. Pressure on the walls, internal energy, and surface quantities such as surfacemore » tension and adsorption are also analyzed for a wide range of densities and temperatures. We have characterized systems from 2 to 6 confined particles, identifying distinctive qualitative behavior over the thermodynamic plane T − ρ, in a few-particle equivalent to phase diagrams of macroscopic systems. Applying the extended law of corresponding states, the square well interaction is mapped to the Asakura-Oosawa model for colloid-polymer mixtures. We link explicitly the temperature of the confined square-well fluid to the equivalent packing fraction of polymers in the Asakura-Oosawa model. Using this approach, we study the confined system of few colloids in a colloid-polymer mixture.« less

  13. Wide emission-tunable CdTeSe/ZnSe/ZnS core–shell quantum dots and their conjugation with E. coli O-157

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Haifeng; Zhou, Guangjun, E-mail: gjzhou@sdu.edu.cn; Zhou, Juan

    2015-05-15

    Highlights: • QDs with variety morphology were obtained via an injection controlled process. • 3-D PL spectra of core–shell QDs show different excitation wavelength dependence. • The PL intensity of QDs with ZnSe transition layer increases dramatically. • Core–shell QDs were processed into aqueous phase and conjugated with E. coli O-157. - Abstract: Wide emission-tunable and different morphological alloyed CdTeSe quantum dots (QDs), CdTeSe/ZnS and CdTeSe/ZnSe/ZnS core–shell QDs were successfully synthesized via an injection controlled process. The effect of injection procedure and reaction temperature were systematically discussed and the growth mechanism was proposed. Most efficient PL wavelength was correlated withmore » reaction time and temperature. The 3-D PL spectra of spherical bare CdTeSe and core–shell QDs with different passivation showed different excitation wavelength dependency. The PL intensity of CdTeSe/ZnSe/ZnS core–shell QDs increased greatly in comparison with that of CdTeSe and CdTeSe/ZnSe QDs. ZnSe transition layer played an important role in improving the PL intensity by providing a smoothened interface and gradient band offsets. The core–shell QDs were transferred into aqueous phase and successfully conjugated with Escherichia coli O-157. The proposed phase-transfer and bio-labeling strategy may be applicable to various QDs with different compositions.« less

  14. Extracellular polymeric substances govern the surface charge of biogenic elemental selenium nanoparticles.

    PubMed

    Jain, Rohan; Jordan, Norbert; Weiss, Stephan; Foerstendorf, Harald; Heim, Karsten; Kacker, Rohit; Hübner, René; Kramer, Herman; van Hullebusch, Eric D; Farges, François; Lens, Piet N L

    2015-02-03

    The origin of the organic layer covering colloidal biogenic elemental selenium nanoparticles (BioSeNPs) is not known, particularly in the case when they are synthesized by complex microbial communities. This study investigated the presence of extracellular polymeric substances (EPS) on BioSeNPs. The role of EPS in capping the extracellularly available BioSeNPs was also examined. Fourier transform infrared (FT-IR) spectroscopy and colorimetric measurements confirmed the presence of functional groups characteristic of proteins and carbohydrates on the BioSeNPs, suggesting the presence of EPS. Chemical synthesis of elemental selenium nanoparticles in the presence of EPS, extracted from selenite fed anaerobic granular sludge, yielded stable colloidal spherical selenium nanoparticles. Furthermore, extracted EPS, BioSeNPs, and chemically synthesized EPS-capped selenium nanoparticles had similar surface properties, as shown by ζ-potential versus pH profiles and isoelectric point measurements. This study shows that the EPS of anaerobic granular sludge form the organic layer present on the BioSeNPs synthesized by these granules. The EPS also govern the surface charge of these BioSeNPs, thereby contributing to their colloidal properties, hence affecting their fate in the environment and the efficiency of bioremediation technologies.

  15. Surface decoration by Spirulina polysaccharide enhances the cellular uptake and anticancer efficacy of selenium nanoparticles.

    PubMed

    Yang, Fang; Tang, Quanming; Zhong, Xueyun; Bai, Yan; Chen, Tianfeng; Zhang, Yibo; Li, Yinghua; Zheng, Wenjie

    2012-01-01

    A simple and solution-phase method for functionalization of selenium nanoparticles (SeNPs) with Spirulina polysaccharides (SPS) has been developed in the present study. The cellular uptake and anticancer activity of SPS-SeNPs were also evaluated. Monodisperse and homogeneous spherical SPS-SeNPs with diameters ranging from 20 nm to 50 nm were achieved under optimized conditions, which were stable in the solution phase for at least 3 months. SPS surface decoration significantly enhanced the cellular uptake and cytotoxicity of SeNPs toward several human cancer cell lines. A375 human melanoma cells were found extremely susceptible to SPS-SeNPs with half maximal (50%) inhibitory concentration value of 7.94 μM. Investigation of the underlying mechanisms revealed that SPS-SeNPs inhibited cancer cell growth through induction of apoptosis, as evidenced by an increase in sub-G(1) cell population, deoxyribonucleic acid fragmentation, chromatin condensation, and phosphatidylserine translocation. Results suggest that the strategy to use SPS as a surface decorator could be an effective way to enhance the cellular uptake and anticancer efficacy of nanomaterials. SPS-SeNPs may be a potential candidate for further evaluation as a chemopreventive and chemotherapeutic agent against human cancers.

  16. Surface decoration by Spirulina polysaccharide enhances the cellular uptake and anticancer efficacy of selenium nanoparticles

    PubMed Central

    Yang, Fang; Tang, Quanming; Zhong, Xueyun; Bai, Yan; Chen, Tianfeng; Zhang, Yibo; Li, Yinghua; Zheng, Wenjie

    2012-01-01

    A simple and solution-phase method for functionalization of selenium nanoparticles (SeNPs) with Spirulina polysaccharides (SPS) has been developed in the present study. The cellular uptake and anticancer activity of SPS-SeNPs were also evaluated. Monodisperse and homogeneous spherical SPS-SeNPs with diameters ranging from 20 nm to 50 nm were achieved under optimized conditions, which were stable in the solution phase for at least 3 months. SPS surface decoration significantly enhanced the cellular uptake and cytotoxicity of SeNPs toward several human cancer cell lines. A375 human melanoma cells were found extremely susceptible to SPS-SeNPs with half maximal (50%) inhibitory concentration value of 7.94 μM. Investigation of the underlying mechanisms revealed that SPS-SeNPs inhibited cancer cell growth through induction of apoptosis, as evidenced by an increase in sub-G1 cell population, deoxyribonucleic acid fragmentation, chromatin condensation, and phosphatidylserine translocation. Results suggest that the strategy to use SPS as a surface decorator could be an effective way to enhance the cellular uptake and anticancer efficacy of nanomaterials. SPS-SeNPs may be a potential candidate for further evaluation as a chemopreventive and chemotherapeutic agent against human cancers. PMID:22359460

  17. Small-incision lenticule extraction versus femtosecond lenticule extraction for myopic: a systematic review and Meta-analysis.

    PubMed

    Wang, Jia-Song; Xie, Hua-Tao; Jia, Ye; Zhang, Ming-Chang

    2017-01-01

    To examine differences in efficacy, accuracy, safety, aberrations and corneal biomechanical between Small incision lenticule extraction (SMILE) and femtosecond lenticule extraction (FLEx) for myopia. Comprehensive studies were conducted on the PubMed, MEDLINE, EMBASE, and Cochrane Controlled Trials Register before 31 July, 2015. Meta-analyses were performed on the primary outcomes [loss of ≥2 lines of corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA) ≥20/20, spherical equivalent (SE) within ±0.50 diopters (D), final refractive SE], secondary outcomes were high-order aberrations (HOAs) and corneal biomechanical [central corneal thickness (CCT), corneal hysteresis (CH) and corneal resistance factor (CRF)]. Seven trials describing a total of 320 eyes with myopia were included in this Meta-analysis. No significant differences were found in the efficacy [UDVA weighted mean difference (WMD) -0.01; 95%CI: -0.04 to 0.01; P =0.37, UDVA ≥20/20, OR 1.49; 95%CI: 0.78 to 2.86; P =0.23], accuracy (SE WMD -0.03; 95%CI: -0.12 to 0.07; P =0.58, SE within ±0.5 D OR 1.25; 95%CI: 0.34 to 4.65; P =0.74), HOAs (WMD -0.04; 95%CI: -0.09 to 0.01; P =0.14) and CCT WMD 1.83; 95%CI: -7.07 to 10.72; P =0.69, CH WMD -0.01; 95%CI: -0.42 to 0.40; P =0.97, CRF WMD 0.17; 95%CI: -0.33 to 0.67; P =0.50) in the last fellow-up. But for safety, FLEx may achieve fewer CDVA lost two or more two lines (OR 11.11; 95%CI: 1.27 to 96.86; P =0.03) than SMILE, however CDVA (WMD 0.00; 95%CI: -0.03 to 0.02; P =0.77) is similar. SMILE and FLEx are comparable in terms of both efficacy, accuracy, aberrations and corneal biomechanical measures in the follow-up, but FLEx seems to be better in safety measures. The results should be interpreted cautiously since relevant evidence is still limited, although it is accumulating. Further large-scale, well-designed randomized controlled trials are urgently needed.

  18. Repeatability and agreement in optical biometry of a new swept-source optical coherence tomography-based biometer versus partial coherence interferometry and optical low-coherence reflectometry.

    PubMed

    Kunert, Kathleen S; Peter, Monika; Blum, Marcus; Haigis, Wolfgang; Sekundo, Walter; Schütze, Juliane; Büehren, Tobias

    2016-01-01

    To estimate the repeatability of biometric parameters obtained with a new swept-source biometer and to compare the agreement with that of partial coherence interferometry (PCI) and optical low-coherence reflectometry (OLCR). Department of Ophthalmology, Helios Hospital Erfurt, Erfurt, Julius-Maximilians University, Würzburg, and Philipps University, Marburg, Germany. Prospective comparative multicenter clinical study. Biometry was taken with the use of 3 different biometers: the IOLMaster 700 swept-source biometer, the PCI-based IOLMaster 500, and the OCLR-based Lenstar LS 900. Axial length (AL), anterior chamber depth (ACD), and spherical equivalent (SE) were compared between swept-source and PCI biometry and central corneal thickness (CCT) and lens thickness (LT) between swept-source and OLCR biometry. The repeatability of swept-source biometry was evaluated on the basis of 3 measurements captured for each patient. One hundred twenty cataract eyes were included in the study. The mean difference between swept-source and PCI biometry for AL, ACD, and SE measurements was 4 μm ± 25 (SD), 17 ± 122 μm, and -0.001 ± 0.19 diopter (D), respectively. The mean difference between swept-source and OLCR biometry for LT and CCT measurements was 21 ± 122 μm and 0.15 ± 4.51 μm, respectively. Differences between swept-source biometry and the other devices distributed around zero without statistical significance. The standard deviation of repeatability for AL, ACD, LT, CCT, and SE was 8.8 μm, 9.8 μm, 2.3 μm, 19.5 μm, and 0.1 D, respectively. Swept-source biometry showed high repeatability performance for all biometric parameters. The agreement of AL, ACD, and SE between swept-source and PCI biometry as well as that of LT and CCT between swept-source and OLCR biometry was excellent. It remains to be validated whether high repeatability shown by swept-source biometry will result in better postoperative refractive outcomes. Drs. Blum and Sekundo are members of the Scientific Advisory Board of Carl Zeiss Meditec AG. Drs. Peter and Bühren are employees of Carl Zeiss Meditec AG. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  19. Relativistic scattered-wave theory. II - Normalization and symmetrization. [of Dirac wavefunctions

    NASA Technical Reports Server (NTRS)

    Yang, C. Y.

    1978-01-01

    Formalisms for normalization and symmetrization of one-electron Dirac scattered-wave wavefunctions are presented. The normalization integral consists of one-dimensional radial integrals for the spherical regions and an analytic expression for the intersphere region. Symmetrization drastically reduces the size of the secular matrix to be solved. Examples for planar Pb2Se2 and tetrahedral Pd4 are discussed.

  20. Use of Spherical Nanoindentation to Characterize the Anisotropic Properties of Microscale Constituents and Interfaces in Hierarchically Structured Composite Materials

    DTIC Science & Technology

    2015-01-24

    Lilleodden, P. Anderson, J.T. Wyrobek, Acta Materialia 44 (1996) 3585-3598. [75] W.W. Gerberich, S. Venkataraman , J. Nelson, H. Huang, E. Lilleodden, W...629-644. [76] W.W. Gerberich, S.K. Venkataraman , H. Huang, S.E. Harvey, D.L. Kohlstedt, Acta Metallurgica et Materialia 43 (1995) 1569. [77] A.E

  1. Formation of highly luminescent Zn1-xCdxSe nanocrystals using CdSe and ZnSe seeds

    NASA Astrophysics Data System (ADS)

    Zhang, Ruili; Yang, Ping

    2013-05-01

    High-quality colloidal Zn1-xCdxSe nanocrystals (NCs) with tunable photoluminescence (PL) from blue to orange were synthesized using oleic acid as a capping agent. The Zn1-xCdxSe NCs were prepared through two approaches: using CdSe or ZnSe seeds. In the case of CdSe NCs as seeds, Zn1-xCdxSe NCs were fabricated by the reaction of Zn, Cd, and Se precursors in the coordinating solvent system at high temperature. The Zn1-xCdxSe NCs revealed orange emitting. A significant blue-shift of absorption and PL spectra were observed with time, indicating the formation of ternary NCs. In contrast, Zn1-xCdxSe NCs revealed blue to green PL for ZnSe NCs as seeds. This is ascribed to an embryonic nuclei-induced alloying process. With increasing time, the Zn1-xCdxSe NCs exhibited a red-shift both in their absorption and PL spectra. This is attributed to the engineering in band gap energy via the control of NC composition. The PL properties of as-prepared alloyed NCs are comparable or even better than those for the parent binary systems. The PL peak wavelength of the Zn1-xCdxSe NCs depended strongly on reaction time and the molar ratio of Cd/Zn. The Zn1-xCdxSe NCs revealed a spherical morphology and exhibited a wurtzite structure according to transmission electron microscopy observation and an X-ray diffraction analysis.

  2. Ganglion cell-inner plexiform layer and retinal nerve fiber layer thickness according to myopia and optic disc area: a quantitative and three-dimensional analysis.

    PubMed

    Seo, Sam; Lee, Chong Eun; Jeong, Jae Hoon; Park, Ki Ho; Kim, Dong Myung; Jeoung, Jin Wook

    2017-03-11

    To determine the influences of myopia and optic disc size on ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (RNFL) thickness profiles obtained by spectral domain optical coherence tomography (OCT). One hundred and sixty-eight eyes of 168 young myopic subjects were recruited and assigned to one of three groups according to their spherical equivalent (SE) values and optic disc area. All underwent Cirrus HD-OCT imaging. The influences of myopia and optic disc size on the GCIPL and RNFL thickness profiles were evaluated by multiple comparisons and linear regression analysis. Three-dimensional surface plots of GCIPL and RNFL thickness corresponding to different combinations of myopia and optic disc size were constructed. Each of the quadrant RNFL thicknesses and their overall average were significantly thinner in high myopia compared to low myopia, except for the temporal quadrant (all Ps ≤0.003). The average and all-sectors GCIPL were significantly thinner in high myopia than in moderate- and/or low-myopia (all Ps ≤0.002). The average OCT RNFL thickness was correlated significantly with SE (0.81 μm/diopter, P < 0.001), axial length (-1.44 μm/mm, P < 0.001), and optic disc area (5.35 μm/mm 2 , P < 0.001) by linear regression analysis. As for the OCT GCIPL parameters, average GCIPL thickness showed a significant correlation with SE (0.84 μm/diopter, P < 0.001) and axial length (-1.65 μm/mm, P < 0.001). There was no significant correlation of average GCIPL thickness with optic disc area. Three-dimensional curves showed that larger optic discs were associated with increased average RNFL thickness and that more-myopic eyes were associated with decreased average GCIPL and RNFL thickness. Myopia can significantly affect GCIPL and RNFL thickness profiles, and optic disc size has a significant influence on RNFL thickness. The current OCT maps employed in the evaluation of glaucoma should be analyzed in consideration of refractive status and optic disc size.

  3. Corneal biomechanical properties in healthy children measured by corneal visualization scheimpflug technology.

    PubMed

    He, Miao; Ding, Hui; He, Hong; Zhang, Chi; Liu, Liangping; Zhong, Xingwu

    2017-05-17

    The aim of this study was to evaluate corneal biomechanical properties in a population of healthy children in China using corneal visualization Scheimpflug technology (CST). All children underwent complete bi-ocular examinations. CST provided intraocular pressure (IOP) and corneal biomechanical parameters, including time, velocity, length and deformation amplitude at first applanation (A1T, A1V, A1L, A1DA), at second applanation (A2T, A2V, A2L, A2DA), highest concavity time (HCT), maximum deformation amplitude (MDA), peak distance (PD), and radius of curvature (RoC). Pearson correlation analysis was used to assess the impacts of demographic factors, central corneal thickness (CCT), spherical equivalent (SE), and IOP on corneal biomechanics. One hundred eight subjects (32 girls and 76 boys) with the mean age of 10.80 ± 4.13 years (range 4 to18 years) were included in the final analyses. The right and left eyes were highly symmetrical in SE (p = 0.082), IOP (p = 0.235), or CCT (p = 0.210). Mean A1T of the right eyes was 7.424 ± 0.340 ms; the left eyes 7.451 ± 0.365 ms. MDA was 0.993 ± 0.102 mm in the right eyes and 0.982 ± 0.100 mm in the left eyes. Mean HCT of the right eyes was 16.675 ± 0.502 ms; the left eyes 16.735 ± 0.555 ms. All CST parameters of both eye were remarkably symmetrical with the exception of A2L (p = 0.006), A1DA (p = 0.025). The majority of CST parameters of both eyes were significantly correlated with CCT and IOP (p < 0.05). However, age, SE, and sex exert little influence on the CST measurements. This study found interocular symmetry in corneal biomechanics in healthy children eyes. Several CST biomechanical parameters in children are modified by CCT and IOP.

  4. Posterior corneal curvature changes following Refractive Small Incision Lenticule Extraction.

    PubMed

    Ganesh, Sri; Patel, Utsav; Brar, Sheetal

    2015-01-01

    To compare the posterior corneal curvature changes, in terms of corneal power and asphercity, following Refractive Small Incision Lenticule Extraction (ReLEx SMILE) procedure for low, moderate, and high myopia. This retrospective, non randomized, comparative, interventional trial; included 52 eyes of 26 patients, divided in three groups: low myopia (myopia ≤3 D [diopters] spherical equivalent [SE]), moderate myopia (myopia >3 D and <6 D SE), and high myopia (myopia ≥6 D SE). All patients were treated for myopia and myopic astigmatism using ReLEx SMILE. The eyes were examined pre-operatively and 3 months post-operatively using SCHWIND SIRIUS, a three-dimensional rotating Scheimpflug camera with a Placido disc topographer to assess corneal changes with regard to keratometric power and asphericity of the cornea. A statistically significant increase in mean keratometric power in the 3, 5, and 7 mm zones of the posterior corneal surface compared with its pre-ReLEx SMILE value was detected after 3 months in the moderate myopia group (pre-operative [pre-op] -6.14±0.23, post-operative [post-op] -6.29±0.22, P<0.001) and high myopia group (pre-op -6.19±0.16, post-op -6.4±0.18, P<0.001), but there was no significant change in keratometric power of the posterior surface in the low myopia group (pre-op -5.87±0.17, post-op -6.06±0.29, P=0.143). Asphericity (Q-value) of the posterior surface changed significantly (P<0.001) after ReLEx SMILE in the moderate myopia group in the 3, 5, and 7 mm zones, and in the high myopia group in the 3 and 7 mm zones; but there was no significant change in the Q-value in the low myopia group in all three zones (pre-op 0.23±0.43, post-op -0.40±0.71, P=0.170), and in the high myopia group in the 5 mm zone (P=0.228). ReLEx SMILE causes significant changes in posterior corneal keratometric power and asphericity in moderate and high myopia, but the effect is subtle and insignificant in low myopia.

  5. Prevalence of refractive error among preschool children in an urban population: the Baltimore Pediatric Eye Disease Study.

    PubMed

    Giordano, Lydia; Friedman, David S; Repka, Michael X; Katz, Joanne; Ibironke, Josephine; Hawes, Patricia; Tielsch, James M

    2009-04-01

    To determine the age-specific prevalence of refractive errors in white and African-American preschool children. The Baltimore Pediatric Eye Disease Study is a population-based evaluation of the prevalence of ocular disorders in children aged 6 to 71 months in Baltimore, Maryland. Among 4132 children identified, 3990 eligible children (97%) were enrolled and 2546 children (62%) were examined. Cycloplegic autorefraction was attempted in all children with the use of a Nikon Retinomax K-Plus 2 (Nikon Corporation, Tokyo, Japan). If a reliable autorefraction could not be obtained after 3 attempts, cycloplegic streak retinoscopy was performed. Mean spherical equivalent (SE) refractive error, astigmatism, and prevalence of higher refractive errors among African-American and white children. The mean SE of right eyes was +1.49 diopters (D) (standard deviation [SD] = 1.23) in white children and +0.71 D (SD = 1.35) in African-American children (mean difference of 0.78 D; 95% confidence interval [CI], 0.67-0.89). Mean SE refractive error did not decline with age in either group. The prevalence of myopia of 1.00 D or more in the eye with the lesser refractive error was 0.7% in white children and 5.5% in African-American children (relative risk [RR], 8.01; 95% CI, 3.70-17.35). The prevalence of hyperopia of +3 D or more in the eye with the lesser refractive error was 8.9% in white children and 4.4% in African-American children (RR, 0.49; 95% CI, 0.35-0.68). The prevalence of emmetropia (<-1.00 D to <+1.00 D) was 35.6% in white children and 58.0% in African-American children (RR, 1.64; 95% CI, 1.49-1.80). On the basis of published prescribing guidelines, 5.1% of the children would have benefited from spectacle correction. However, only 1.3% had been prescribed correction. Significant refractive errors are uncommon in this population of urban preschool children. There was no evidence for a myopic shift over this age range in this cross-sectional study. A small proportion of preschool children would likely benefit from refractive correction, but few have had this prescribed.

  6. Topographic corneal changes after collagen cross-linking in patients with corneal keratoconus.

    PubMed

    Razmjoo, Hasan; Nasrollahi, Alireza Peyman Kobra; Salam, Hasan; Karbasi, Najmeh; Najarzadegan, Mohammad Reza

    2013-10-01

    Corneal collagen cross-linking with riboflavin, also known as collagen cross-linking (CXL), involves the application of riboflavin solution to the eye that is activated by illumination with ultraviolet A (UVA) light. We survey here the topographic corneal changes one year after CXL in patients with corneal keratoconus. This prospective randomized clinical trial study comprised 66 patients with progression of keratoconus during one year who were enrolled at Feiz University Referral Eye Center in Isfahan. Before and after the operation, patients were examined with slit lamp and funduscopic examinations and measurement of uncorrected visual acuity (UCVA), and best spectacle-corrected visual acuity (BSCVA) was done with a logarithm of minimal angle of resolution (logMAR) scale. Corneal topographic and pachymetry values were derived from Orbscan II. The paired t-test test was used for statistical analyses with SPSS software version 20 (SPSS Inc., Chicago, IL, USA). All 66 patients completed postoperative follow-up at 12 months. The mean age of the patients was 22.4 ± 5.4 years (range: 18-29 years). Thirty-six (54.55%) subjects were men and 30 (45.45%) were women. The mean preoperative sphere was -2.66 ± 2.14 diopter (D), the mean cylinder was -3.97 ± 2.29, and the mean spherical equivalent (SE) was -4.64 ± 2.56. Postoperatively, the mean sphere was -2.22 ± 2.57 D, the mean cylinder was -3.60 ± 2.40 D, and SE was -4.02 ± 2.93 D (P = 0.037). SE also demonstrated a mean difference of 0.62 ± 0.37 D significantly (P = 0.006). The mean diameter of preoperative posterior best-fit sphere (BFS) was 6.33 ± 0.35mm (range: 5.51-7.73 mm) before operation, and it improved to 6.28 ± 0.34mm (range: 4.36-6.13 mm) after operation; the difference was significant (P = 0.039). Our study showed a significant improvement in topographic corneal changes and refractive results in patients with corneal ectasia after CXL.

  7. Topographic corneal changes after collagen cross-linking in patients with corneal keratoconus

    PubMed Central

    Razmjoo, Hasan; Nasrollahi, Alireza Peyman Kobra; Salam, Hasan; Karbasi, Najmeh; Najarzadegan, Mohammad Reza

    2013-01-01

    Background: Corneal collagen cross-linking with riboflavin, also known as collagen cross-linking (CXL), involves the application of riboflavin solution to the eye that is activated by illumination with ultraviolet A (UVA) light. We survey here the topographic corneal changes one year after CXL in patients with corneal keratoconus. Materials and Methods: This prospective randomized clinical trial study comprised 66 patients with progression of keratoconus during one year who were enrolled at Feiz University Referral Eye Center in Isfahan. Before and after the operation, patients were examined with slit lamp and funduscopic examinations and measurement of uncorrected visual acuity (UCVA), and best spectacle-corrected visual acuity (BSCVA) was done with a logarithm of minimal angle of resolution (logMAR) scale. Corneal topographic and pachymetry values were derived from Orbscan II. The paired t-test test was used for statistical analyses with SPSS software version 20 (SPSS Inc., Chicago, IL, USA). Results: All 66 patients completed postoperative follow-up at 12 months. The mean age of the patients was 22.4 ± 5.4 years (range: 18-29 years). Thirty-six (54.55%) subjects were men and 30 (45.45%) were women. The mean preoperative sphere was −2.66 ± 2.14 diopter (D), the mean cylinder was −3.97 ± 2.29, and the mean spherical equivalent (SE) was −4.64 ± 2.56. Postoperatively, the mean sphere was −2.22 ± 2.57 D, the mean cylinder was −3.60 ± 2.40 D, and SE was −4.02 ± 2.93 D (P = 0.037). SE also demonstrated a mean difference of 0.62 ± 0.37 D significantly (P = 0.006). The mean diameter of preoperative posterior best-fit sphere (BFS) was 6.33 ± 0.35mm (range: 5.51-7.73 mm) before operation, and it improved to 6.28 ± 0.34mm (range: 4.36-6.13 mm) after operation; the difference was significant (P = 0.039). Conclusion: Our study showed a significant improvement in topographic corneal changes and refractive results in patients with corneal ectasia after CXL. PMID:24497860

  8. Six-year changes in refraction and related ocular biometric factors in an adult Chinese population.

    PubMed

    Han, Xiaotong; Guo, Xinxing; Lee, Pei Ying; Morgan, Ian G; He, Mingguang

    2017-01-01

    To investigate longitudinal changes in refraction and biometry in Chinese adults. Population-based prospective cohort study. 1817 subjects aged ≥ 35 years were randomly recruited from Yuexiu district, Guangzhou, China in 2008. Of which 1595 (87.8%) were reexamined in 2010 and 1427 (78.5%) were reexamined in 2014. Non-cycloplegic automated refraction and visual acuity test were performed at baseline and the 6-year follow-up examination for all participants. In addition, 50% of the participants were randomly selected for axial length (AL), anterior chamber depth (ACD) and lens thickness (LT) measurements using non-contact partial coherence laser interferometry. Lens power (LP) was calculated with the Bennett's equation. A total of 1300 participants were included in current analysis (2008 mean [SD] age, 51.4 [10.6] years; 54.5% women). Mean change in spherical equivalence (SE) was +0.24 (95% confidence interval [CI], +0.19 to +0.30), +0.51 (95% CI, +0.46 to +0.57), +0.26 (95% CI, +0.15 to +0.38) and -0.05 (95% CI, -0.21 to +0.10) diopters (D) for individuals in the age groups of 35 to 44, 45 to 54, 55 to 64 and 65+ years at baseline, respectively. Corneal power, AL and LT increased while ACD and LP decreased during the follow-up. Baseline SE and changes in biometric factors could explain 97.2% of the variance in longitudinal SE change while LP solely could explain 65.2%. Six-year mean change in cylinder power was -0.16 (95% CI, -0.19 to -0.13) D, the axis of astigmatism changed from "with-the-rule" to "against-the-rule" in 16.4% of the participants and to "oblique" in 0.9%. This study confirms a hyperopic shift in the elderly before 65 years old and a myopic shift thereafter. Longitudinal refraction change could be well explained by corresponding biometry changes, especially LP. There is also a shift to "against-the-rule" astigmatism for the adult population.

  9. Six-year changes in refraction and related ocular biometric factors in an adult Chinese population

    PubMed Central

    Han, Xiaotong; Guo, Xinxing; Lee, Pei Ying; Morgan, Ian G.; He, Mingguang

    2017-01-01

    Purpose To investigate longitudinal changes in refraction and biometry in Chinese adults. Design Population-based prospective cohort study. Methods 1817 subjects aged ≥ 35 years were randomly recruited from Yuexiu district, Guangzhou, China in 2008. Of which 1595 (87.8%) were reexamined in 2010 and 1427 (78.5%) were reexamined in 2014. Non-cycloplegic automated refraction and visual acuity test were performed at baseline and the 6-year follow-up examination for all participants. In addition, 50% of the participants were randomly selected for axial length (AL), anterior chamber depth (ACD) and lens thickness (LT) measurements using non-contact partial coherence laser interferometry. Lens power (LP) was calculated with the Bennett’s equation. Results A total of 1300 participants were included in current analysis (2008 mean [SD] age, 51.4 [10.6] years; 54.5% women). Mean change in spherical equivalence (SE) was +0.24 (95% confidence interval [CI], +0.19 to +0.30), +0.51 (95% CI, +0.46 to +0.57), +0.26 (95% CI, +0.15 to +0.38) and -0.05 (95% CI, -0.21 to +0.10) diopters (D) for individuals in the age groups of 35 to 44, 45 to 54, 55 to 64 and 65+ years at baseline, respectively. Corneal power, AL and LT increased while ACD and LP decreased during the follow-up. Baseline SE and changes in biometric factors could explain 97.2% of the variance in longitudinal SE change while LP solely could explain 65.2%. Six-year mean change in cylinder power was -0.16 (95% CI, -0.19 to -0.13) D, the axis of astigmatism changed from “with-the-rule” to “against-the-rule” in 16.4% of the participants and to “oblique” in 0.9%. Conclusions This study confirms a hyperopic shift in the elderly before 65 years old and a myopic shift thereafter. Longitudinal refraction change could be well explained by corresponding biometry changes, especially LP. There is also a shift to “against-the-rule” astigmatism for the adult population. PMID:28854269

  10. On the interpretations of Langevin stochastic equation in different coordinate systems

    NASA Astrophysics Data System (ADS)

    Martínez, E.; López-Díaz, L.; Torres, L.; Alejos, O.

    2004-01-01

    The stochastic Langevin Landau-Lifshitz equation is usually utilized in micromagnetics formalism to account for thermal effects. Commonly, two different interpretations of the stochastic integrals can be made: Ito and Stratonovich. In this work, the Langevin-Landau-Lifshitz (LLL) equation is written in both Cartesian and Spherical coordinates. If Spherical coordinates are employed, the noise is additive, and therefore, Ito and Stratonovich solutions are equal. This is not the case when (LLL) equation is written in Cartesian coordinates. In this case, the Langevin equation must be interpreted in the Stratonovich sense in order to reproduce correct statistical results. Nevertheless, the statistics of the numerical results obtained from Euler-Ito and Euler-Stratonovich schemes are equivalent due to the additional numerical constraint imposed in Cartesian system after each time step, which itself assures that the magnitude of the magnetization is preserved.

  11. Laser diffraction of acicular particles: practical applications

    NASA Astrophysics Data System (ADS)

    Scott, David M.; Matsuyama, Tatsushi

    2014-08-01

    Commercial laser diffraction instruments are widely used to measure particle size distribution (PSD), but the results are distorted for non-spherical (acicular) particles often encountered in practical applications. Consequently the distribution, which is reported in terms of equivalent spherical diameter, requires interpretation. For rod-like and plate-like particles, the PSD tends to be bi-modal, with the two modal sizes closely related to the median length and width, or width and thickness, of the particles. Furthermore, it is found that the bi-modal PSD for at least one instrument can typically be approximated by a bi-lognormal distribution. By fitting such a function to the reported distribution, one may extract quantitative information useful for process or product development. This approach is illustrated by examples of such measurement on industrial samples of polymer particles, crystals, bacteria, and clays.

  12. Outwardly Propagating Flames at Elevated Pressures

    NASA Technical Reports Server (NTRS)

    Law, C. K.; Rozenchan, G.; Tse, S. D.; Zhu, D. L.

    2001-01-01

    Spherical, outwardly-propagating flames of CH4-O2-inert and H2-O2-inert mixtures were experimentally studied in a high pressure apparatus. Stretch-free flame speeds and Markstein lengths were extracted for a wide range of pressures and equivalence ratios for spherically-symmetric, smooth flamefronts and compared to numerical computations with detailed chemistry and transport, as well as existing data in the literature. Wrinkle development was examined for propagating flames that were unstable under our experimental conditions. Hydrodynamic cells developed for most H2-air and CH4-air flames at elevated pressures, while thermal-diffusive instabilities were also observed for lean and near-stoichiometric hydrogen flames at pressures above atmospheric. Strategies in suppressing or delaying the onset of cell formation have been assessed. Buoyancy effects affected sufficiently off-stoichiometric CH4 mixtures at high pressures.

  13. The burden of pure anisometropic amblyopia: a cross-sectional study on 2800 Iranians.

    PubMed

    Akbarzadeh, Siamak; Vahabi, Reihaneh; Bazzazi, Nooshin; Roshanaei, Ghodratollah; Heydarian, Samira; Fouladi, Daniel F

    2018-02-01

    To assess the proportion of pure anisometropic amblyopia in a sample Iranian (white) population. A total of 2800 consecutive individuals who presented at a referral eye clinic for any reason were examined for the presence of pure anisometropic amblyopia. Anisometropia was reported when a spherical equivalent refraction difference of at least 1.0 D with or without a cylinder refraction difference of at least 1.0 D was present between the two eyes. Amblyopia was defined as the best-corrected visual acuity of 20/30 or worse or a two-line interocular visual acuity difference between eyes that could not be attributed to any structural ocular pathology or visual pathway abnormality. Subjects were 1528 females and 1272 males with a mean age of 30.25 ± 14.93 years (range, 5-65). Amblyopia was diagnosed in 192 cases (6.9%), significantly more frequent among females (7.9 vs. 5.7%, p = 0.02). Pure anisometropic amblyopia was present in 6.1% of the study population, significantly more common in patients with spherical hyperopic anisometropia (37.7%) compared to patients with spherical myopic anisometropia (21.3%), cylindrical myopic anisometropia (4.1%), and cylindrical hyperopic anisometropia (15%) (p < 0.001). Pure anisometropic amblyopia is a common finding in Caucasians seeking eye care, particularly when anisometropia is of spherical hyperopic subtype.

  14. The drag and lift of different non-spherical particles from low to high Re

    NASA Astrophysics Data System (ADS)

    Sanjeevi, Sathish K. P.; Padding, Johan

    2017-11-01

    The present work investigates a simplified drag and lift model that can be used for different non-spherical particles. The flow around different non-spherical particles is studied using a multi-relaxation-time lattice Boltzmann method. We compute the mean drag coefficient CD , ϕ at different incident angles ϕ for a wide range of Reynolds numbers (Re). We show that the sine-squared drag law CD , ϕ =CD , ϕ =0° +(CD , ϕ =90° -CD , ϕ =0°) sin2 ϕ holds up to large Reynolds numbers Re = 2000 . The sine-squared dependence of CD occurs at Stokes flow (very low Re) due to linearity of the flow fields. We explore the physical origin behind the sine-squared law at high Re , and reveal that surprisingly, this does not occur due to linearity of flow fields. Instead, it occurs due to an interesting pattern of pressure distribution contributing to the drag, at higher Re , for different incident angles. Similarly, we find that the equivalent theoretical equation of lift coefficient CL can provide a decent approximation, even at high Re , for elongated particles. Such a drag and lift law valid at high Re is very much useful for Euler-Lagrangian fluidization simulations of the non-spherical particles. European Research Council (ERC) consolidator Grant scheme, Contract No. 615096 (NonSphereFlow).

  15. Refractive astigmatism and the toricity of ocular components in human infants.

    PubMed

    Mutti, Donald O; Mitchell, G Lynn; Jones, Lisa A; Friedman, Nina E; Frane, Sara L; Lin, Wendy K; Moeschberger, Melvin L; Zadnik, Karla

    2004-10-01

    Many studies have characterized astigmatism in infancy, but few have been longitudinal or contained ocular component data. This study characterized the frequency, orientation, and longitudinal change with age of infant astigmatism. Additional factors investigated were the influence of early astigmatism on emmetropization and its relation to corneal and lenticular toricity. Three hundred two infants were enrolled in the study. Of these, 298 provided data for at least one visit at 3 +/- 1 months, 9 +/- 1 months, 18 +/- 2 months, and 36 +/- 3 months. Testing included cycloplegic retinoscopy (cyclopentolate 1%), video-based keratophakometry, and ultrasonography over the closed eyelid. Astigmatism > or =1.00 DC was common at 3 months of age (41.6%) but decreased in prevalence to 4.1% by 36 months (p < 0.0001). The most common orientation was with-the-rule at 3 months (37.0% compared with 2.7% for against-the-rule) but against-the-rule at 36 months (3.2% compared with 0.9% for with-the-rule). Most of the change in the average value of the horizontal/vertical component of astigmatism (J0) occurred between 3 and 9 months (-0.26 +/- 0.36 D; p < 0.0001) with no significant change between 9 and 36 months (-0.05 +/- 0.36 D; p=0.09). Spherical equivalent refractive error was not correlated with J0 at 3 and 9 months (R=0.002, p=0.48 and R=0.001, p=0.56, respectively). The two were only weakly correlated at 18 and 36 months (R=0.06 for each age, p <0.0001, p=0.0002, respectively). Changes in spherical equivalent between 3 and 9 months were unrelated to either the initial value of J0 (partial R for J0=0.0001; p=0.85) or the change in J0 (partial R for change in J0=0.0031; p=0.31). Across all the ages, corneal toricity was with-the-rule, and lenticular toricity was against-the-rule (produced by the toricity of the posterior lens surface). The cornea and anterior lens surface became more spherical with age, contributing to the shift away from with-the-rule refractive astigmatism. Toricity of all the refractive surfaces became less variable with age. Consistent with many reports, astigmatism was common in early infancy but decreased in prevalence with age, particularly when with-the-rule in orientation. The reduction in percentage of infants with astigmatism appeared to be caused by decreases in the toricity of the cornea and the anterior lens combined with decreases in the variability of corneal and lenticular surfaces. Astigmatism in infancy appeared to be unrelated to emmetropization of spherical equivalent refractive error.

  16. The Infrared & Electro-Optical Systems Handbook. Emerging Systems and Technologies, Volume 8

    DTIC Science & Technology

    1993-01-01

    usually associated with turbulence in the intervening path or to significant nonuniformities in com- position or temperature of the air within the field of...cause beam quality to be less than perfect. Coatings on the mirrors can also be nonuniform , leading to further OPD effects. Resonator misalignment...despite an undesired spherical error). Coatings can be nonuniform in their thickness. This thickness nonuniform - ity is equivalent to a mirror fabrication

  17. Deconstruction of the Maldacena Núñez compactification

    NASA Astrophysics Data System (ADS)

    Andrews, R. P.; Dorey, N.

    2006-09-01

    We demonstrate a classical equivalence between the large- N limit of the higgsed N=1 SUSY U(N) Yang-Mills theory and the Maldacena-Núñez twisted compactification of a six-dimensional gauge theory on a two-sphere. A direct comparison of the actions and spectra of the two theories reveals them to be identical. We also propose a gauge theory limit which should describe the corresponding spherical compactification of little string theory.

  18. Development of Commercially Useable Codes to Simulate Aluminized Propellant Combustion and Related Issues

    DTIC Science & Technology

    2009-11-03

    functions and the second derivative of Green’s function. We exploit the geometrical characteristics of our integrand, i.e., we use spherical coordinates...statistically equivalent medium. Both the fully resolved probability spectrum and the geometrically exact particle shapes are considered in this...18 Buckmaster Research A1-18 FA9550-07-C-0123 References [1] B.D. Lubachevsky and F.H. Stillinger. “ Geometric properties of random disk packings”, J

  19. Depth dose measurements with the Liulin-5 experiment inside the spherical phantom of the MATROSHKA-R project onboard the International Space Station

    NASA Astrophysics Data System (ADS)

    Semkova, J.; Koleva, R.; Maltchev, St.; Bankov, N.; Benghin, V.; Chernykh, I.; Shurshakov, V.; Petrov, V.; Drobyshev, S.; Nikolaev, I.

    2012-02-01

    The Liulin-5 experiment is a part of the international project MATROSHKA-R on the Russian segment of the ISS, which uses a tissue-equivalent spherical phantom equipped with a set of radiation detectors. The objective of the MATROSHKA-R project is to provide depth dose distribution of the radiation field inside the sphere in order to get more information on the distribution of dose in a human body. Liulin-5 is a charged particle telescope using three silicon detectors. It measures time resolved energy deposition spectra, linear energy transfer (LET) spectra, particle flux, and absorbed doses of electrons, protons and heavy ions, simultaneously at three depths along the radius of the phantom. Measurements during the minimum of the solar activity in cycle 23 show that the average absorbed daily doses at 40 mm depth in the phantom are between 180 μGy/day and 220 μGy/day. The absorbed doses at 165 mm depth in the phantom decrease by a factor of 1.6-1.8 compared to the doses at 40 mm depth due to the self-shielding of the phantom from trapped protons. The average dose equivalent at 40 mm depth is 590 ± 32 μSV/day and the galactic cosmic rays (GCR) contribute at least 70% of the total dose equivalent at that depth. Shown is that due to the South Atlantic Anomaly (SAA) trapped protons asymmetry and the direction of Liulin-5 lowest shielding zone the dose rates on ascending and descending nodes in SAA are different. The data obtained are compared to data from other radiation detectors on ISS.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kaur, Ramneek; Tripathi, S. K., E-mail: surya@pu.ac.in, E-mail: surya-tr@yahoo.com

    This paper reports the synthesis and electrical characterization of CdSe-PMMA nanocomposite. CdSe-PMMA nanocomposite has been prepared by ex-situ technique through chemical route. The influence of three different Ag doping concentrations on the electrical properties has been studied in the temperature range ∼ 303-353 K. Transmission electron micrograph reveals the spherical morphology of the CdSe nanoparticles and their proper dispersion in the PMMA matrix. The electrical conduction of the polymer nanocomposites is through thermally activated process with single activation energy. With Ag doping, initially the activation energy increases upto 0.2 % Ag doping concentration but with further increase in Ag concentration, itmore » decreases. This behavior has been discussed on the basis of randomly oriented grain boundaries and defect states. Thus, the results indicate that the transport properties of the polymer nanocomposites can be tailored by controlled doping concentration.« less

  1. Selenomethionine as a Safer Substitute for Barium Selenate in Long-Acting Injectable Se Supplements for Food-Producing Animals.

    PubMed

    Knowles, Scott O; Grace, Neville D

    2017-09-20

    Nutritional supplementation with selenium (Se) can prevent Se deficiency in food-producing animals. Injection with slow-release formulations is a preferred method for free-range grazing sheep and cattle, and barium selenate (BaSeO 4 ) provides optimal efficacy. This chemical can become a health risk to humans if the concentrated depot of an injection site is consumed, and consequently such use is recently banned in the EU. A possible replacement is selenomethionine (SeMet), a naturally occurring form of Se supplementation hitherto only administered orally. In four animal studies we found that injection with SeMet maintained nutritionally adequate concentrations of Se in blood and tissues of lambs for at least 191 days and in blood and milk of dairy cows for at least 95 days. Stereoisomer forms L- and DL-SeMet were functionally equivalent. This is the first demonstration that injectable SeMet can deliver efficacy similar to BaSeO 4 but with less risk of undesirable residues in edible tissues.

  2. Selenium nanoparticles synthesized in aqueous extract of Allium sativum perturbs the structural integrity of Calf thymus DNA through intercalation and groove binding.

    PubMed

    Ezhuthupurakkal, Preedia Babu; Polaki, Lokeswara Rao; Suyavaran, Arumugam; Subastri, Ariraman; Sujatha, Venugopal; Thirunavukkarasu, Chinnasamy

    2017-05-01

    Biomedical application of selenium nanoparticles (SeNPs) demands the eco-friendly composite for synthesis of SeNPs. The present study reports an aqueous extract of Allium sativum (AqEAS) plug-up the current need. Modern spectroscopic, microscopic and gravimetric techniques were employed to characterize the synthesized nanoparticles. Characterization studies revealed the formation of crystalline spherical shaped SeNPs. FTIR spectrum brings out the presence of different functional groups in AqEAS, which influence the SeNPs formation and stabilization. Furthermore the different aspects of the interaction between SeNPs and CT-DNA were scrutinized by various spectroscopic and cyclic voltametric studies. The results reveals the intercalation and groove binding mode of interaction of SeNPs with stacked base pair of CT-DNA. The Stern-Volmer quenching constant (K SV ) were found to be 7.02×10 6 M- 1 (ethidium bromide), 4.22×10 6 M- 1 (acridine orange) and 7.6×10 6 M- 1 (Hoechst) indicating strong binding of SeNPs with CT-DNA. The SeNPs - CT-DNA interactions were directly visualized by atomic force microscopy. The present study unveils the cost effective, innocuous, highly stable SeNPs intricate mechanism of DNA interaction, which will be a milestone in DNA targeted chemotherapy. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. One-Pot Synthesis of CoSex -rGO Composite Powders by Spray Pyrolysis and Their Application as Anode Material for Sodium-Ion Batteries.

    PubMed

    Park, Gi Dae; Kang, Yun Chan

    2016-03-14

    A simple one-pot synthesis of metal selenide/reduced graphene oxide (rGO) composite powders for application as anode materials in sodium-ion batteries was developed. The detailed mechanism of formation of the CoSe(x)-rGO composite powders that were selected as the first target material in the spray pyrolysis process was studied. The crumple-structured CoSe(x)-rGO composite powders prepared by spray pyrolysis at 800 °C had a crystal structure consisting mainly of Co0.85 Se with a minor phase of CoSe2. The bare CoSe(x) powders prepared for comparison had a spherical shape and hollow structure. The discharge capacities of the CoSe(x)-rGO composite and bare CoSe(x) powders in the 50th cycle at a constant current density of 0.3 A g(-1) were 420 and 215 mA h g(-1), respectively, and their capacity retentions measured from the second cycle were 80 and 46%, respectively. The high structural stability of the CoSe(x)-rGO composite powders for repeated sodium-ion charge and discharge processes resulted in superior sodium-ion storage properties compared to those of the bare CoSe(x) powders. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Biosynthesis of selenium nanoparticles using Enterococcus faecalis and evaluation of their antibacterial activities.

    PubMed

    Shoeibi, Sara; Mashreghi, Mohammad

    2017-01-01

    Microorganisms are capable of synthesizing metal nanoparticles, and specifically Enterococcus faecalis bacteria were tested for its ability to synthesize selenium nanoparticles (Se-NPs) from sodium selenite. The biosynthesized Se-NPs were spherical in shape with the size range of 29-195nm. Also, the TEM microscopy showed the accumulation of nano-structures as extracellular deposits. The ability of the bacteria to tolerate high levels of toxic selenite was studied by changing with different concentrations of sodium selenite (0.19mM-2.97mM). Also, the effect of Se-NPs was studied on the growth profile of number of pathogenic Gram-positive and -negative bacteria. High concentrations of sodium selenite in the medium led to the production of small amounts of selenium nanostructures by bacteria. In addition, Se-NPs can be used as an anti-staphylococcal element to effectively prevent and treat S. aureus infections. Copyright © 2016 Elsevier GmbH. All rights reserved.

  5. Amplified all-optical polarization phase modulator assisted by a local surface plasmon in Au-hybrid CdSe quantum dots.

    PubMed

    Kyhm, Kwangseuk; Je, Koo-Chul; Taylor, Robert A

    2012-08-27

    We propose an amplified all-optical polarization phase modulator assisted by a local surface plasmon in Au-hybrid CdSe quantum dots. When the local surface plasmon of a spherical Au quantum dot is in resonance with the exciton energy level of a CdSe quantum dot, a significant enhancement of the linear and nonlinear refractive index is found in both the real and imaginary terms via the interaction with the dipole field of the local surface plasmon. Given a gating pulse intensity, an elliptical polarization induced by the phase retardation is described in terms of elliptical and rotational angles. In the case that a larger excitation than the bleaching intensity is applied, the signal light can be amplified due to the presence of gain in the CdSe quantum dot. This enables a longer propagation of the signal light relative to the metal loss, resulting in more feasible polarization modulation.

  6. Understanding the paradox of selenium contamination in mercury mining areas: high soil content and low accumulation in rice.

    PubMed

    Zhang, Hua; Feng, Xinbin; Jiang, Chengxin; Li, Qiuhua; Liu, Yi; Gu, Chunhao; Shang, Lihai; Li, Ping; Lin, Yan; Larssen, Thorjørn

    2014-05-01

    Rice is an important source of Se for billions of people throughout the world. The Wanshan area can be categorized as a seleniferous region due to its high soil Se content, but the Se content in the rice in Wanshan is much lower than that from typical seleniferous regions with an equivalent soil Se level. To investigate why the Se bioaccumulation in Wanshan is low, we measured the soil Se speciation using a sequential partial dissolution technique. The results demonstrated that the bioavailable species only accounted for a small proportion of the total Se in the soils from Wanshan, a much lower quantity than that found in the seleniferous regions. The potential mechanisms may be associated with the existence of Hg contamination, which is likely related to the formation of an inert Hg-Se insoluble precipitate in soils in Wanshan. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Elastic medium equivalent to Fresnel's double-refraction crystal.

    PubMed

    Carcione, José M; Helbig, Klaus

    2008-10-01

    In 1821, Fresnel obtained the wave surface of an optically biaxial crystal, assuming that light waves are vibrations of the ether in which longitudinal vibrations (P waves) do not propagate. An anisotropic elastic medium mathematically analogous to Fresnel's crystal exists. The medium has four elastic constants: a P-wave modulus, associated with a spherical P wave surface, and three elastic constants, c(44), c(55), and c(66), associated with the shear waves, which are mathematically equivalent to the three dielectric permittivity constants epsilon(11), epsilon(22), and epsilon(33) as follows: mu(0)epsilon(11)<==>rho/c(44), mu(0)epsilon(22)<==>rho/c(55), mu(0)epsilon(33)<==>rho/c(66), where mu(0) is the magnetic permeability of vacuum and rho is the mass density. These relations also represent the equivalence between the elastic and electromagnetic wave velocities along the principal axes of the medium. A complete mathematical equivalence can be obtained by setting the P-wave modulus equal to zero, but this yields an unstable elastic medium (the hypothetical ether). To obtain stability the P-wave velocity has to be assumed infinite (incompressibility). Another equivalent Fresnel's wave surface corresponds to a medium with anomalous polarization. This medium is physically unstable even for a nonzero P-wave modulus.

  8. Refractive Errors Affect the Vividness of Visual Mental Images

    PubMed Central

    Palermo, Liana; Nori, Raffaella; Piccardi, Laura; Zeri, Fabrizio; Babino, Antonio; Giusberti, Fiorella; Guariglia, Cecilia

    2013-01-01

    The hypothesis that visual perception and mental imagery are equivalent has never been explored in individuals with vision defects not preventing the visual perception of the world, such as refractive errors. Refractive error (i.e., myopia, hyperopia or astigmatism) is a condition where the refracting system of the eye fails to focus objects sharply on the retina. As a consequence refractive errors cause blurred vision. We subdivided 84 individuals according to their spherical equivalent refraction into Emmetropes (control individuals without refractive errors) and Ametropes (individuals with refractive errors). Participants performed a vividness task and completed a questionnaire that explored their cognitive style of thinking before their vision was checked by an ophthalmologist. Although results showed that Ametropes had less vivid mental images than Emmetropes this did not affect the development of their cognitive style of thinking; in fact, Ametropes were able to use both verbal and visual strategies to acquire and retrieve information. Present data are consistent with the hypothesis of equivalence between imagery and perception. PMID:23755186

  9. Refractive errors affect the vividness of visual mental images.

    PubMed

    Palermo, Liana; Nori, Raffaella; Piccardi, Laura; Zeri, Fabrizio; Babino, Antonio; Giusberti, Fiorella; Guariglia, Cecilia

    2013-01-01

    The hypothesis that visual perception and mental imagery are equivalent has never been explored in individuals with vision defects not preventing the visual perception of the world, such as refractive errors. Refractive error (i.e., myopia, hyperopia or astigmatism) is a condition where the refracting system of the eye fails to focus objects sharply on the retina. As a consequence refractive errors cause blurred vision. We subdivided 84 individuals according to their spherical equivalent refraction into Emmetropes (control individuals without refractive errors) and Ametropes (individuals with refractive errors). Participants performed a vividness task and completed a questionnaire that explored their cognitive style of thinking before their vision was checked by an ophthalmologist. Although results showed that Ametropes had less vivid mental images than Emmetropes this did not affect the development of their cognitive style of thinking; in fact, Ametropes were able to use both verbal and visual strategies to acquire and retrieve information. Present data are consistent with the hypothesis of equivalence between imagery and perception.

  10. Equivalent Knee Injury and Osteoarthritis Outcome Scores 12 and 24 Months After Anterior Cruciate Ligament Reconstruction: Results From the Swedish National Knee Ligament Register.

    PubMed

    Samuelsson, Kristian; Magnussen, Robert A; Alentorn-Geli, Eduard; Krupic, Ferid; Spindler, Kurt P; Johansson, Christer; Forssblad, Magnus; Karlsson, Jón

    2017-07-01

    It is not clear whether Knee injury and Osteoarthritis Outcome Score (KOOS) results will be different 1 or 2 years after anterior cruciate ligament (ACL) reconstruction. To investigate within individual patients enrolled in the Swedish National Knee Ligament Register whether there is equivalence between KOOS at 1 and 2 years after primary ACL reconstruction. Cohort study; Level of evidence, 2. This cohort study was based on data from the Swedish National Knee Ligament Register during the period January 1, 2005, through December 31, 2013. The longitudinal KOOS values for each individual at the 1- and 2-year follow-up evaluations were assessed through the two one-sided test (TOST) procedure with an acceptance criterion of 4. Subset analysis was performed with patients classified by sex, age, graft type, and type of injury (meniscal and/or cartilage injury). A total of 23,952 patients were eligible for analysis after exclusion criteria were applied (10,116 women, 42.2%; 13,836 men, 57.8%). The largest age group was between 16 and 20 years of age (n = 6599; 27.6%). The most common ACL graft was hamstring tendon (n = 22,504; 94.0%), of which the combination of semitendinosus and gracilis was the most common. A total of 7119 patients reported on the KOOS Pain domain at both 1- and 2-year follow-ups, with a mean difference of 0.21 (13.1 SD, 0.16 SE [90% CI, -0.05 to 0.46], P < .001). The same results were found for the other KOOS subscales: symptoms (mean difference -0.54, 14.1 SD, 0.17 SE [90% CI, -0.81 to -0.26], P < .001), activities of daily living (mean difference 0.45, 10.8 SD, 0.13 SE [90% CI, 0.24 to 0.66], P < .001), sports and recreation (mean difference -0.35, 22.7 SD, 0.27 SE [90% CI, -0.79 to 0.09], P < .001), quality of life (mean difference -0.92, 20.0 SD, 0.24 SE [90% CI, -1.31 to -0.53], P < .001), and the combined KOOS-4 score (mean difference -0.41, 14.5 SD, 0.17 SE [90% CI, -0.70 to -0.13], P < .001). Analyses within specific subsets of patients showed equivalent results between the 2 follow-up evaluations. Equivalent results within patients were found in KOOS values at 1- and 2-year follow-ups after ACL reconstruction. The finding was consistent across all KOOS subscales and for all evaluated subsets of patients. This result implies that there is no additional value in capturing both 1- and 2-year KOOS outcomes after ACL reconstruction. However, these findings of equivalence at 1- and 2-year endpoints do not alleviate the need for longer follow-up periods.

  11. Efficient molecular density functional theory using generalized spherical harmonics expansions.

    PubMed

    Ding, Lu; Levesque, Maximilien; Borgis, Daniel; Belloni, Luc

    2017-09-07

    We show that generalized spherical harmonics are well suited for representing the space and orientation molecular density in the resolution of the molecular density functional theory. We consider the common system made of a rigid solute of arbitrary complexity immersed in a molecular solvent, both represented by molecules with interacting atomic sites and classical force fields. The molecular solvent density ρ(r,Ω) around the solute is a function of the position r≡(x,y,z) and of the three Euler angles Ω≡(θ,ϕ,ψ) describing the solvent orientation. The standard density functional, equivalent to the hypernetted-chain closure for the solute-solvent correlations in the liquid theory, is minimized with respect to ρ(r,Ω). The up-to-now very expensive angular convolution products are advantageously replaced by simple products between projections onto generalized spherical harmonics. The dramatic gain in speed of resolution enables to explore in a systematic way molecular solutes of up to nanometric sizes in arbitrary solvents and to calculate their solvation free energy and associated microscopic solvent structure in at most a few minutes. We finally illustrate the formalism by tackling the solvation of molecules of various complexities in water.

  12. Ocular higher-order aberrations and axial eye growth in young Hong Kong children.

    PubMed

    Lau, Jason K; Vincent, Stephen J; Collins, Michael J; Cheung, Sin-Wan; Cho, Pauline

    2018-04-30

    This retrospective longitudinal analysis aimed to investigate the association between ocular higher-order aberrations (HOAs) and axial eye growth in Hong Kong children. Measures of axial length and ocular HOAs under cycloplegia were obtained annually over a two-year period from 137 subjects aged 8.8 ± 1.4 years with mean spherical equivalent refraction of -2.04 ± 2.38 D. A significant negative association was observed between the RMS of total HOAs and axial eye growth (P = 0.03), after adjusting for other significant predictors of axial length including age, sex and refractive error. Similar negative associations with axial elongation were found for the RMS of spherical aberrations ([Formula: see text] and [Formula: see text] combined) (P = 0.037). Another linear mixed model also showed that greater levels of vertical trefoil [Formula: see text], primary spherical aberration [Formula: see text] and negative oblique trefoil [Formula: see text] were associated with slower axial elongation and longer axial length (all P < 0.05). These findings support the potential role of HOAs, image quality and a vision-dependent mechanism in childhood eye growth.

  13. Two space scatterer formalism calculation of bulk parameters of thunderclouds

    NASA Technical Reports Server (NTRS)

    Phanord, Dieudonne D.

    1994-01-01

    In a previous study, we used a modified two-space scatterer formalism of Twersky to establish for a cloud modeled as a statistically homogeneous distribution of spherical water droplets, the dispersion relations that determine its bulk propagation numbers and bulk indexes of refraction in terms of the vector equivalent scattering amplitude and the dyadic scattering amplitude of the single water droplet in isolation. The results were specialized to the forward direction of scattering while demanding that the scatterers preserve the incident polarization. We apply this approach to obtain specific numerical values for the macroscopic parameters of the cloud. We work with a cloud of density rho = 100 cm(exp -3), a wavelength lambda = 0.7774 microns, and with spherical water droplets of common radius alpha = 10 microns. In addition, the scattering medium is divided into three parts, the medium outside the cloud, moist air (the medium inside the cloud but outside the droplets), and the medium inside the spherical water droplets. The results of this report are applicable to a cloud of any geometry since the boundary does not interfere with the calculations. Also, it is important to notice the plane wave nature of the incidence wave in the moist atmosphere.

  14. Verlet scheme non-conservativeness for simulation of spherical particles collisional dynamics and method of its compensation

    NASA Astrophysics Data System (ADS)

    Savin, Andrei V.; Smirnov, Petr G.

    2018-05-01

    Simulation of collisional dynamics of a large ensemble of monodisperse particles by the method of discrete elements is considered. Verle scheme is used for integration of the equations of motion. Non-conservativeness of the finite-difference scheme is discovered depending on the time step, which is equivalent to a pure-numerical energy source appearance in the process of collision. Compensation method for the source is proposed and tested.

  15. The role of axial length-corneal radius of curvature ratio in refractive state categorization in a nigerian population.

    PubMed

    Iyamu, Eghosasere; Iyamu, Joy; Obiakor, Christian Izuchukwu

    2011-01-01

    The aim of this study was to investigate the association of axial length (AL)/corneal radius of curvature (CRC) ratio (AL/CRC) with spherical equivalent refractive state (SER) in young adults. A total of seventy (n = 70) subjects consisting of 31 males and 39 females participated in this study. Subjects were categorized into emmetropia, hyperopia and myopia using the spherical equivalent refraction. The axial length was measured with I-2100 A-Scan ultrasonography/Biometer (CIMA Technology, USA), the corneal radius of curvature with Bausch & Lomb H-135A (Bausch & Lomb Corp., USA), and the refractive state by static retinoscopy and subjective refraction. The mean AL, CRC and AL/CRC ratio of all subjects were 23.74 ± 0.70 mm, 7.84 ± 0.19 mm, and 3.03 ± 0.14, respectively. Myopes had significantly longer AL, steeper CRC and higher AL/CRC ratio than the emmetropes and hyperopes. There was statistically significant inverse correlation between AL and CRC (r = -0.53, P < 0.0001), SER (r = -0.64, P < 0.0001), and between SER and AL/CRC (r = -0.78, P < 0.0001). A significant positive correlation was found between CRC and SER (r = -0.69, P < 0.0001). The categorization of the refractive state of an individual is better done by using the AL/CRC ratio index.

  16. Relationship between lenticular power and refractive error in children with hyperopia

    PubMed Central

    Tomomatsu, Takeshi; Kono, Shinjiro; Arimura, Shogo; Tomomatsu, Yoko; Matsumura, Takehiro; Takihara, Yuji; Inatani, Masaru; Takamura, Yoshihiro

    2013-01-01

    Objectives To evaluate the contribution of axial length, and lenticular and corneal power to the spherical equivalent refractive error in children with hyperopia between 3 and 13 years of age, using noncontact optical biometry. Methods There were 62 children between 3 and 13 years of age with hyperopia (+2 diopters [D] or more) who underwent automated refraction measurement with cycloplegia, to measure spherical equivalent refractive error and corneal power. Axial length was measured using an optic biometer that does not require contact with the cornea. The refractive power of the lens was calculated using the Sanders-Retzlaff-Kraff formula. Single regression analysis was used to evaluate the correlation among the optical parameters. Results There was a significant positive correlation between age and axial length (P = 0.0014); however, the degree of hyperopia did not decrease with aging (P = 0.59). There was a significant negative correlation between age and the refractive power of the lens (P = 0.0001) but not that of the cornea (P = 0.43). A significant negative correlation was observed between the degree of hyperopia and lenticular power (P < 0.0001). Conclusion Although this study is small scale and cross sectional, the analysis, using noncontact biometry, showed that lenticular power was negatively correlated with refractive error and age, indicating that lower lens power may contribute to the degree of hyperopia. PMID:23576859

  17. An evaluation of the accuracy of the ORange (Gen II) by comparing it to the IOLMaster in the prediction of postoperative refraction.

    PubMed

    Chen, Ming

    2012-01-01

    The aim of this study was to evaluate the accuracy of ORange(®) Gen II (WaveTec Vision, Aliso Viejo, CA). The Surgical Suites, Honolulu, HI. The prospective 28 consecutive cataract surgical cases were selected from 85 cataract surgical cases between December 16, 2010 and February 24, 2011. With the same intraocular lens implantation, the predicted spherical equivalent refraction from IOLMaster(®) (Carl Zeiss AG, Oberkochen, Germany) and ORange Gen II were statistically compared and verified with 1-month postoperative manifest refraction. The data were put into IBM SPSS 19 (SPSS Inc, Chicago, IL) for analysis of variance. Pearson's correlation coefficient was also calculated to evaluate the correlation between the IOLMaster, ORange Gen II, and 1-month postoperative manifest refraction. There were no statistically significant differences in the mean spherical equivalent refraction from the IOLMaster, ORange Gen II, and 1-month postoperative manifest refraction (IOLMaster -0.40 diopters, P = 0.07; ORange Gen II -0.43 diopters, P = 0.16; 1-month refraction -0.41 diopters, P = 0.07). Pearson's correlation study demonstrated that all three were positively correlated (P < 0.05), with the strongest correlation between the ORange Gen II and 1-month postoperative manifest refraction (r = +0.6, P < 0.01). The ORange Gen II can be considered as an alternative method for intraocular lens selection for cataract patients.

  18. Relationship between refractive error and ocular biometrics in twin children: the Guangzhou Twin Eye Study.

    PubMed

    Wang, Decai; Liu, Bin; Huang, Shengsong; Huang, Wenyong; He, Mingguang

    2014-09-01

    A cross-sectional study was conducted to explore the relationship between refractive error and ocular biometrics in children from the Guangzhou twin eye study. Twin participants aged 7-15 years were selected from Guangzhou Twin Eye Study. Ocular examinations included visual acuity measurement, ocular motility evaluation, autorefraction under cycloplegia, and anterior segment, media, and fundus examination. Axial length (AL), anterior chamber depth (ACD), and corneal curvature radius were measured using partial coherence laser interferometry. A multivariate linear regression model was used for statistical analysis. Twin children from Guangzhou city showed a decreased spherical equivalent with age, whereas both AL and ACD were increased and corneal curvature radius remained unchanged. When adjusted by age and gender, the data from 77% of twins presenting with spherical equivalent changes indicated that these were caused by predictable variables (R2 = 0.77, P < 0.001). Primary factors affecting children's refraction included axial length (β = -0.97,P < 0.001), ACD (β = 0.33, P < 0.001), and curvature radius (β = 2.10, P < 0.001). Girls had a higher tendency for myopic status than did boys (β = -0.26, P < 0.001). Age exerted no effect upon the changes in refraction (β = -0.01, P = 0.25). Refraction is correlated with ocular biometrics. Refractive status is largely determined by axial length as the major factor.

  19. Limiting diffusion current at rotating disk electrode with dense particle layer.

    PubMed

    Weroński, P; Nosek, M; Batys, P

    2013-09-28

    Exploiting the concept of diffusion permeability of multilayer gel membrane and porous multilayer we have derived a simple analytical equation for the limiting diffusion current at rotating disk electrode (RDE) covered by a thin layer with variable tortuosity and porosity, under the assumption of negligible convection in the porous film. The variation of limiting diffusion current with the porosity and tortuosity of the film can be described in terms of the equivalent thickness of stagnant solution layer, i.e., the average ratio of squared tortuosity to porosity. In case of monolayer of monodisperse spherical particles, the equivalent layer thickness is an algebraic function of the surface coverage. Thus, by means of cyclic voltammetry of RDE with a deposited particle monolayer we can determine the monolayer surface coverage. The effect of particle layer adsorbed on the surface of RDE increases non-linearly with surface coverage. We have tested our theoretical results experimentally by means of cyclic voltammetry measurements of limiting diffusion current at the glassy carbon RDE covered with a monolayer of 3 μm silica particles. The theoretical and experimental results are in a good agreement at the surface coverage higher than 0.7. This result suggests that convection in a monolayer of 3 μm monodisperse spherical particles is negligibly small, in the context of the coverage determination, in the range of very dense particle layers.

  20. Solar Equivalences of the Earth’s Primary Exergy inflows and the Theoretical Basis for Secondary and Tertiary Emergy Flows of the Geobiosphere: New Calculations of Transformities

    EPA Science Inventory

    Brown et al. (2016) published a synthesis paper in which evidence was presented supporting a new value of the Earth’s geobiosphere baseline, 12.0E+24 seJ/y (solar equivalent joules per year) from which the emergy of all the Earth’s products and processes can be calcul...

  1. Biomimetic synthesis of selenium nanospheres by bacterial strain JS-11 and its role as a biosensor for nanotoxicity assessment: a novel se-bioassay.

    PubMed

    Dwivedi, Sourabh; Alkhedhairy, Abdulaziz A; Ahamed, Maqusood; Musarrat, Javed

    2013-01-01

    Selenium nanoparticles (Se-NPs) were synthesized by green technology using the bacterial isolate Pseudomonas aeruginosa strain JS-11. The bacteria exhibited significant tolerance to selenite (SeO3(2-)) up to 100 mM concentration with an EC50 value of 140 mM. The spent medium (culture supernatant) contains the potential of reducing soluble and colorless SeO3(2-) to insoluble red elemental selenium (Se(0)) at 37°C. Characterization of red Se° product by use of UV-Vis spectroscopy, X-ray diffraction (XRD), atomic force microscopy (AFM) and transmission electron microscopy (TEM) with energy dispersive X-ray spectrum (EDX) analysis revealed the presence of stable, predominantly monodispersed and spherical selenium nanoparticles (Se-NPs) of an average size of 21 nm. Most likely, the metabolite phenazine-1-carboxylic acid (PCA) released by strain JS-11 in culture supernatant along with the known redox agents like NADH and NADH dependent reductases are responsible for biomimetic reduction of SeO3(2-) to Se° nanospheres. Based on the bioreduction of a colorless solution of SeO3(2-) to elemental red Se(0), a high throughput colorimetric bioassay (Se-Assay) was developed for parallel detection and quantification of nanoparticles (NPs) cytotoxicity in a 96 well format. Thus, it has been concluded that the reducing power of the culture supernatant of strain JS-11 could be effectively exploited for developing a simple and environmental friendly method of Se-NPs synthesis. The results elucidated that the red colored Se° nanospheres may serve as a biosensor for nanotoxicity assessment, contemplating the inhibition of SeO3(2-) bioreduction process in NPs treated bacterial cell culture supernatant, as a toxicity end point.

  2. Wideband and multi-frequency infrared cloaking of spherical objects by using the graphene-based metasurface.

    PubMed

    Shokati, Elnaz; Granpayeh, Nosrat; Danaeifar, Mohammad

    2017-04-10

    The ultrathin graphene metasurface is proposed as a mantle cloak to achieve wideband tunable scattering reduction around the spherical (three-dimensional) objects. The cloaking shell over the metallic or dielectric sphere is structured by a periodic array of graphene nanodisks that operate at infrared frequencies. By using the polarizability of the graphene nanodisks and equivalent conductivity method, the metasurface reactance is obtained. To achieve the cloaking shell for both dielectric and conducting spheres, the metasurface reactance as a function of nanodisks dimensions, graphene's Fermi energy, and permittivity of the surrounding areas can be tuned from the inductive to capacitive situation. Inhomogeneous metasurfaces including graphene nanodisks with different radii provide wideband invisibility due to extra resonances. We could significantly increase the 3-dB bandwidth more than the homogenous case by simpler realistic designs compared to the multi-layer structures. The analytical results are confirmed with full-wave numerical simulations.

  3. High-resolution Local Gravity Model of the South Pole of the Moon from GRAIL Extended Mission Data

    NASA Technical Reports Server (NTRS)

    Goossens, Sander Johannes; Sabaka, Terence J.; Nicholas, Joseph B.; Lemoine, Frank G.; Rowlands, David D.; Mazarico, Erwan; Neumann, Gregory A.; Smith, David E.; Zuber, Maria T.

    2014-01-01

    We estimated a high-resolution local gravity field model over the south pole of the Moon using data from the Gravity Recovery and Interior Laboratory's extended mission. Our solution consists of adjustments with respect to a global model expressed in spherical harmonics. The adjustments are expressed as gridded gravity anomalies with a resolution of 1/6deg by 1/6deg (equivalent to that of a degree and order 1080 model in spherical harmonics), covering a cap over the south pole with a radius of 40deg. The gravity anomalies have been estimated from a short-arc analysis using only Ka-band range-rate (KBRR) data over the area of interest. We apply a neighbor-smoothing constraint to our solution. Our local model removes striping present in the global model; it reduces the misfit to the KBRR data and improves correlations with topography to higher degrees than current global models.

  4. AgCl-doped CdSe quantum dots with near-IR photoluminescence.

    PubMed

    Kotin, Pavel Aleksandrovich; Bubenov, Sergey Sergeevich; Mordvinova, Natalia Evgenievna; Dorofeev, Sergey Gennadievich

    2017-01-01

    We report the synthesis of colloidal CdSe quantum dots doped with a novel Ag precursor: AgCl. The addition of AgCl causes dramatic changes in the morphology of synthesized nanocrystals from spherical nanoparticles to tetrapods and finally to large ellipsoidal nanoparticles. Ellipsoidal nanoparticles possess an intensive near-IR photoluminescence ranging up to 0.9 eV (ca. 1400 nm). In this article, we explain the reasons for the formation of the ellipsoidal nanoparticles as well as the peculiarities of the process. The structure, Ag content, and optical properties of quantum dots are also investigated. The optimal conditions for maximizing both the reaction yield and IR photoluminescence quantum yield are found.

  5. Size-dependent magnetic properties of cubic-phase MnSe nanospheres emitting blue-violet fluorescence

    NASA Astrophysics Data System (ADS)

    Das, Kishan; AhmedMir, Irshad; Ranjan, Rahul; Bohidar, H. B.

    2018-05-01

    We report a facile controlled synthesis of non-iron based cubic phase MnSe magnetic nanocrystals with well-defined spherical shape of different size (7–16 nm, TEM data) by hot injection method without need for special conditions. It was found that the size and its polydispersity could be easily controlled by controlling the reaction temperature. The highly crystalline (confirmed by XRD) synthesized nanoparticles showed blue-violet fluorescence emission and were antiferromagnet in nature. The observed size dependent weak ferromagnetism, resulting hysteresis loop in antiferromagnet was attributed to the surface spins. Strengthening of antiferromagnetism with increasing size could be the reason for shifting of the freezing temperature towards higher side.

  6. Thermodynamic stability in elastic systems: Hard spheres embedded in a finite spherical elastic solid.

    PubMed

    Solano-Altamirano, J M; Goldman, Saul

    2015-12-01

    We determined the total system elastic Helmholtz free energy, under the constraints of constant temperature and volume, for systems comprised of one or more perfectly bonded hard spherical inclusions (i.e. "hard spheres") embedded in a finite spherical elastic solid. Dirichlet boundary conditions were applied both at the surface(s) of the hard spheres, and at the outer surface of the elastic solid. The boundary conditions at the surface of the spheres were used to describe the rigid displacements of the spheres, relative to their initial location(s) in the unstressed initial state. These displacements, together with the initial positions, provided the final shape of the strained elastic solid. The boundary conditions at the outer surface of the elastic medium were used to ensure constancy of the system volume. We determined the strain and stress tensors numerically, using a method that combines the Neuber-Papkovich spherical harmonic decomposition, the Schwartz alternating method, and Least-squares for determining the spherical harmonic expansion coefficients. The total system elastic Helmholtz free energy was determined by numerically integrating the elastic Helmholtz free energy density over the volume of the elastic solid, either by a quadrature, or a Monte Carlo method, or both. Depending on the initial position of the hard sphere(s) (or equivalently, the shape of the un-deformed stress-free elastic solid), and the displacements, either stationary or non-stationary Helmholtz free energy minima were found. The non-stationary minima, which involved the hard spheres nearly in contact with one another, corresponded to lower Helmholtz free energies, than did the stationary minima, for which the hard spheres were further away from one another.

  7. Probing charge transfer in a novel class of luminescent perovskite-based heterostructures composed of quantum dots bound to RE-activated CaTiO 3 phosphors

    DOE PAGES

    Crystal S. Lewis; Wong, Stanislaus S.; Liu, Haiqing; ...

    2016-01-04

    We report on the synthesis and structural characterization of novel semiconducting heterostructures composed of cadmium selenide (CdSe) quantum dots (QDs) attached onto the surfaces of novel high-surface area, porous rare-earth-ion doped alkaline earth titanate micron-scale spherical motifs, i.e. both Eu-doped and Pr-doped CaTiO 3, composed of constituent, component nanoparticles. These unique metal oxide perovskite building blocks were created by a multi-pronged synthetic strategy involving molten salt and hydrothermal protocols. Subsequently, optical characterization of these heterostructures indicated a clear behavioral dependence of charge transfer in these systems upon a number of parameters such as the nature of the dopant, the reactionmore » temperature, and particle size. Specifically, 2.7 nm diameter ligand-functionalized CdSe QDs were anchored onto sub-micron sized CaTiO 3-based spherical assemblies, prepared by molten salt protocols. We found that both the Pr- and Eu-doped CaTiO 3 displayed pronounced PL emissions, with maximum intensities observed using optimized lanthanide concentrations of 0.2 mol% and 6 mol%, respectively. Analogous experiments were performed on Eu-doped BaTiO 3 and SrTiO 3 motifs, but CaTiO 3 still performed as the most effective host material amongst the three perovskite systems tested. Furthermore, the ligand-capped CdSe QD-doped CaTiO 3 heterostructures exhibited effective charge transfer between the two individual constituent nanoscale components, an assertion corroborated by the corresponding quenching of their measured PL signals.« less

  8. Enhanced oxidation stability of quasi core-shell alloyed CdSeS quantum dots prepared through aqueous microwave synthesis technique.

    PubMed

    Zhan, Hong-Ju; Zhou, Pei-Jiang; Ma, Rong; Liu, Xi-Jing; He, Yu-Ning; Zhou, Chuan-Yun

    2014-01-01

    Quasi core shell alloyed CdSeS quantum dots (QDs) have been prepared through a facile aqueous-phase route employing microwave irradiation technique. The optical spectroscopy and structure characterization evidenced the quasi core shell alloyed structures of CdSeS QDs. The X-ray diffraction patterns of the obtained CdSeS QDs displayed peak positions very close to those of bulk cubic CdS crystal structures and the result of X-ray photoelectron spectroscopy data re-confirmed the thick CdS shell on the CdSe core. The TEM images and HRTEM images of the CdSeS QDs ascertained the well-defined spherical particles and a relatively narrow size distribution. On the basis, the stability of the obtained QDs in an oxidative environment was also discussed using etching reaction by H2O2. The experiments result showed the as-prepared QDs present high tolerance towards H2O2, obviously superior to the commonly used CdTe QDs and core-shell CdTe/CdS QDs, which was attributed to the unique quasi core-shell CdSeS crystal structure and the small lattice mismatch between CdSe and CdS semiconductor materials. This assay provided insight to obtain high stable crystal structured semiconductor nanocrystals in the design and synthesis process.

  9. Meta-analysis of gender differences in residual stroke risk and major bleeding in patients with nonvalvular atrial fibrillation treated with oral anticoagulants.

    PubMed

    Pancholy, Samir B; Sharma, Parikshit S; Pancholy, Dipti S; Patel, Tejas M; Callans, David J; Marchlinski, Francis E

    2014-02-01

    Studies comparing gender-specific outcomes in patients with atrial fibrillation (AF) have reported conflicting results. Gender differences in cerebrovascular accident/systemic embolism (CVA/SE) or major bleeding outcomes with novel oral anticoagulant (NOAC) use are not known. The goal of this analysis was to perform a systematic review and meta-analysis evaluating gender differences in residual risk of CVA/SE and major bleeding outcomes in patients with nonvalvular AF treated with either warfarin or NOAC. Sixty-four randomized studies were identified using keywords "gender," "AF," and "CVA." Using the Preferred Reporting Items for Systemic Reviews and Meta-analysis method, 6 studies met criteria for inclusion in this meta-analysis. CVA/SE and major bleeding outcomes were separately analyzed in cohorts receiving warfarin and NOAC agents, comparing men with women. Women with AF taking warfarin were at a significantly greater residual risk of CVA/SE compared with men (odds ratio 1.279, 95% confidence interval 1.111 to 1.473, Z = -3.428, p = 0.001). No gender difference in residual risk of CVA/SE was noted in patients with AF receiving NOAC agents (odds ratio 1.146, 95% confidence interval 0.97 to 1.354, p = 0.109). Major bleeding was less frequent in women with AF treated with NOAC. In conclusion, women with AF treated with warfarin have a greater residual risk of CVA/SE and an equivalent major bleeding risk, whereas those treated with NOAC agents deemed superior to warfarin are at equivalent residual risk of CVA/SE and less major bleeding risk compared with men. These results suggest an increased net clinical benefit of NOAC agents compared with warfarin in treating women with AF. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Atomic level characterization of cadmium selenide nanocrystal systems using atomic number contrast scanning transmission electron microscopy and Rutherford backscattering spectroscopy

    NASA Astrophysics Data System (ADS)

    McBride, James R.

    This project involved the characterization of CdSe nanocrystals. Through the use of Atomic Number Contrast Scanning Transmission Electron Microscopy (Z-STEM) and Rutherford Backscattering Spectroscopy (RBS), atomic level structure and chemical information was obtained. Specifically, CdSe nanocrystals produced using a mixture of hexadecylamine (HDA) and trioctylphosphine oxide (TOPO) were determined to be spherical compared to nanocrystals produced in TOPO only, which had elongated (101) facets. Additionally, the first Z-STEM images of CdSe/ZnS core/shell nanocrystals were obtained. From these images, the growth mechanism of the ZnS shell was determined and the existence of non-fluorescent ZnS particles was confirmed. Through collaboration with Quantum Dot Corp., core/shell nanocrystals with near unity quantum yield were developed. These core/shell nanocrystals included a US intermediate layer to improve shell coverage.

  11. Nanocrystalline Chalcopyrite Materials (CuInS2 and CuInSe2) via Low-Temperature Pyrolysis of Molecular Single-Source Precursors

    NASA Technical Reports Server (NTRS)

    Castro, Stephanie L.; Bailey, Sheila G.; Raffaelle, Ryne P.; Banger, Kulbinder K.; Hepp, Aloysius F.

    2003-01-01

    Nanometer sized particles of the chalcopyrite compounds CuInS2 and CuInSe2 were synthesized by thermal decomposition of molecular single-source precursors (PPh3)2CuIn(SEt)4 and (PPh3)2CuIn(SePh)4, respectively, in the non-coordinating solvent dioctyl phthalate at temperatures between 200 and 300 C. The nanoparticles range in size from 3 - 30 nm and are aggregated to form roughly spherical clusters of about 500 nm in diameter. X-ray diffraction of the nanoparticle powders shows greatly broadened lines indicative of very small particle sizes, which is confirmed by TEM. Peaks present in the XRD can be indexed to reference patterns for the respective chalcopyrite compounds. Optical spectroscopy and elemental analysis by energy dispersive spectroscopy support the identification of the nanoparticles as chalcopyrites.

  12. Modelling and Microstructural Characterization of Sintered Metallic Porous Materials

    PubMed Central

    Depczynski, Wojciech; Kazala, Robert; Ludwinek, Krzysztof; Jedynak, Katarzyna

    2016-01-01

    This paper presents selected characteristics of the metallic porous materials produced by the sintering of metal powders. The authors focus on materials produced from the iron powder (Fe) of ASC 100.29 and Distaloy SE. ASC 100.29 is formed by atomization and has a characteristic morphology. It consists of spherical particles of different sizes forming agglomerates. Distaloy SE is also based on the sponge-iron. The porous material is prepared using the patented method of sintering the mixture of iron powder ASC 100.29, Fe(III) oxide, Distaloy SE and Fe(III) oxide in the reducing atmosphere of dissociated ammonia. As a result, the materials with open pores of micrometer sizes are obtained. The pores are formed between iron particles bonded by diffusion bridges. The modelling of porous materials containing diffusion bridges that allows for three-dimensional (3D) imaging is presented. PMID:28773690

  13. A facile growth mechanism, structural, optical, dielectric and electrical properties of ZnSe nanosphere via hydrothermal process

    NASA Astrophysics Data System (ADS)

    Javed, Qurat-Ul-Ain; Baqi, Sabah; Abbas, Hussain; Bibi, Maryam

    2017-02-01

    Hydrothermal method was chosen as a convenient method to fabricate zinc selenide (ZnSe) nanoparticle materials. The prepared nanospheres were characterized using X-ray diffraction (XRD) and scanning electron microscopy (SEM), where its different properties were observed using UV-visible spectroscopy and LCR meter. It was found that the pure ZnSe nanoparticles have a Zinc blende structure with crystallite size 10.91 nm and in a spherical form with average diameter of 35 nm (before sonication) and 18 nm (after sonication) with wide band gap of 4.28 eV. It was observed that there is inverse relation of frequency with dielectric constant and dielectric loss while AC conductivity grows up by increasing frequency. Such nanostructures were determined to be effectively used in optoelectronic devices as UV detector and in those devices where high-dielectric constant materials are required.

  14. Choroidal Thickness in 3001 Chinese Children Aged 6 to 19 Years Using Swept-Source OCT

    PubMed Central

    Xiong, Shuyu; He, Xiangui; Deng, Junjie; Lv, Minzhi; Jin, Jiali; Sun, Sifei; Yao, Chunxia; Zhu, Jianfeng; Zou, Haidong; Xu, Xun

    2017-01-01

    The purpose of the cross-sectional study is to describe the values and distribution of choroidal thickness and to explore its related factors, especially age, in Chinese children. A total of 3001 Chinese school children aged 6 to 19 years underwent comprehensive ophthalmic examinations, including axial length and cycloplegic refraction. Choroidal thickness was measured by swept-source optical coherence tomography (SS-OCT). There was a greater difference in the more central regions between the myopes and emmetropes. Multiple regression analysis was performed to determine the associated factors of choroidal thickness. The results demonstrated that age was independently positively related to choroidal thickness for emmetropes (β = 3.859, p < 0.001), and mild myopes with spherical equivalent greater than −2.00 D (−1.25 D < spherical equivalent ≤ −0.50 D: β = 3.476, p = 0.006; −2.00 D < spherical equivalent ≤ −1.25 D: β = 3.232, p = 0.020). However, no significant relationship between age and choroidal thickness was found in children with spherical equivalent ≤ −2.00 D, suggesting that the protective effect of physiologic choroidal growth with age against rapid axial elongation disappeared while axial elongation becomes the dominant determinant of choroidal thickness among children with myopia worse than −2.00 D. PMID:28327553

  15. Further Evidence for Increasing Pressure and a Non-spherical Shape in Triton's Atmosphere

    NASA Astrophysics Data System (ADS)

    Person, M. J.; Elliot, J. L.; McDonald, S. W.; Buie, M. W.; Dunham, E. W.; Millis, R. L.; Nye, R. A.; Olkin, C. B.; Wasserman, L. H.; Young, L. A.; Hubbard, W. B.; Hill, R.; Reitsema, H. J.; Pasachoff, J. M.; Babcock, B. A.; McConnochie, T. M.; Stone, R. C.

    2000-10-01

    An occultation by Triton of a star denoted as Tr176 by McDonald & Elliot (AJ 109, 1352), was observed on 1997 July 18 from various locations in Australia and North America. After an extensive prediction effort, two complete chords of the occultation were recorded by our PCCD portable data systems. These chords were combined with three others recorded by another group (Sicardy et al., BAAS 30, 1107) to provide an overall geometric solution for Triton's atmosphere at the occultation pressure. A simple circular fit to these five chords yielded a half-light radius of 1439 +/- 10 km, however least squares fitting revealed a significant deviation from the simple circular projection of a spherical atmosphere. The best fitting ellipse (a first order deviation from the circular solution) yielded a mean radius of 1440 +/- 6 km and an ellipticity of 0.040 +/- 0.003. To further characterize the non-spherical solutions to the geometric fits, methods were developed to analyze the data assuming both circular and elliptical profiles. Circular and elliptically focused light curve models corresponding to the best fitting circular and elliptical geometric solutions were fit to the data. Using these light curve fits, the mean pressure at the 1400 km radius (48 km altitude) derived from all the data was 2.23 +/- 0.28 microbar for the circular model and 2.45 +/- 0.32 microbar for the elliptical model. These pressures agree with those for the Tr180 occultation (which occurred a few months later), so these results are consistent with the conclusions of Elliot et al. (Icarus 143, 425) that Triton's surface pressure has increased from 14.0 microbar at the time of the Voyager encounter to 19.0 microbar in 1997. The mean equivalent-isothermal temperature at 1400 km was 43.6 +/- 3.7 K for the circular model and 42.0 +/- 3.6 K for the elliptical model. Within their calculated errors, the equivalent-isothermal temperatures were the same for all Triton latitudes probed.

  16. Profile of refractive errors in European Caucasian children with Autistic Spectrum Disorder; increased prevalence and magnitude of astigmatism.

    PubMed

    Anketell, Pamela M; Saunders, Kathryn J; Gallagher, Stephen; Bailey, Clare; Little, Julie-Anne

    2016-07-01

    Autistic Spectrum Disorder (ASD) is a common neurodevelopmental disorder characterised by impairment of communication, social interaction and repetitive behaviours. Only a small number of studies have investigated fundamental clinical measures of vision including refractive error. The aim of this study was to describe the refractive profile of a population of children with ASD compared to typically developing (TD) children. Refractive error was assessed using the Shin-Nippon NVision-K 5001 open-field autorefractor following the instillation of cyclopentolate hydrochloride 1% eye drops. A total of 128 participants with ASD (mean age 10.9 ± 3.3 years) and 206 typically developing participants (11.5 ± 3.1 years) were recruited. There was no significant difference in median refractive error, either by spherical equivalent or most ametropic meridian between the ASD and TD groups (Spherical equivalent, Mann-Whitney U307 = 1.15, p = 0.25; Most Ametropic Meridian, U305 = 0.52, p = 0.60). Median refractive astigmatism was -0.50DC (range 0.00 to -3.50DC) for the ASD group and -0.50DC (Range 0.00 to -2.25DC) for the TD group. Magnitude and prevalence of refractive astigmatism (defined as astigmatism ≥1.00DC) was significantly greater in the ASD group compared to the typically developing group (ASD 26%, TD 8%, magnitude U305 = 3.86, p = 0.0001; prevalence (χ12=17.71 , p < 0.0001). This is the first study to describe the refractive profile of a population of European Caucasian children with ASD compared to a TD population of children. Unlike other neurodevelopmental conditions, there was no increased prevalence of spherical refractive errors in ASD but astigmatic errors were significantly greater in magnitude and prevalence. This highlights the need to examine refractive errors in this population. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.

  17. Non-spherical Lobate Chondrules in CO3.0 Y-81020: General Implications for the Formation of Low-FeO Porphyritic Chondrules in CO Chondrites

    NASA Technical Reports Server (NTRS)

    Rubin, Alan E.; Wasson, John T.

    2006-01-01

    Non-spherical chondrules (arbitrarily defined as having aspect ratios greater than or equal to 1.20) in CO3.0 chondrites comprise multi-lobate, distended, and highly irregular objects with rounded margins; they constitute approx. 70% of the type-I (low-FeO) porphyritic chondrules in Y-81020, approx. 75% of such chondrules in ALHA77307, and approx. 60% of those in Colony. Although the proportion of non-spherical type-I chondrules in LL3.0 Semarkona is comparable (approx. 60%), multi-lobate OC porphyritic chondrules (with lobe heights equivalent to a significant fraction of the mean chondrule diameter) are rare. If the non-spherical type-I chondrules in CO chondrites had formed from totally molten droplets, calculations indicate that they would have collapsed into spheres within approx. 10(exp -3) s, too little time for their 20-micrometer-size olivine phenocrysts to have grown from the melt. These olivine grains must therefore be relicts from an earlier chondrule generation; the final heating episode experienced by the non-spherical chondrules involved only minor amounts of melting and crystallization. The immediate precursors of the individual non-spherical chondrules may have been irregularly shaped chondrule fragments whose fracture surfaces were rounded during melting. Because non-spherical chondrules and circular chondrules form a continuum in shape and have similar grain sizes, mineral and mesostasis compositions, and modal abundances of non-opaque phases, they must have formed by related processes. We conclude that a large majority of low-FeO chondrules in CO3 chondrites experienced a late, low-degree melting event. Previous studies have shown that essentially all type-II (high-FeO) porphyritic chondrules in Y-81020 formed by repeated episodes of low-degree melting. It thus appears that the type-I and type-II porphyritic chondrules in Y-81020 (and, presumably, all CO3 chondrites) experienced analogous formation histories. Because these two types constitute approx. 95% of all CO chondrules, it is clear that chondrule recycling was the rule in the CO chondrule-formation region and that most melting events produced only low degrees of melting. The rarity of significantly non-spherical, multi-lobate chondrules in Semarkona may reflect more-intense heating of chondrule precursors in the ordinary-chondrite region of the solar nebula.

  18. Profile and Determinants of Retinal Optical Intensity in Normal Eyes with Spectral Domain Optical Coherence Tomography.

    PubMed

    Chen, Binyao; Gao, Enting; Chen, Haoyu; Yang, Jianling; Shi, Fei; Zheng, Ce; Zhu, Weifang; Xiang, Dehui; Chen, Xinjian; Zhang, Mingzhi

    2016-01-01

    To investigate the profile and determinants of retinal optical intensity in normal subjects using 3D spectral domain optical coherence tomography (SD OCT). A total of 231 eyes from 231 healthy subjects ranging in age from 18 to 80 years were included and underwent a 3D OCT scan. Forty-four eyes were randomly chosen to be scanned by two operators for reproducibility analysis. Distribution of optical intensity of each layer and regions specified by the Early Treatment of Diabetic Retinopathy Study (ETDRS) were investigated by analyzing the OCT raw data with our automatic graph-based algorithm. Univariate and multivariate analyses were performed between retinal optical intensity and sex, age, height, weight, spherical equivalent (SE), axial length, image quality, disc area and rim/disc area ratio (R/D area ratio). For optical intensity measurements, the intraclass correlation coefficient of each layer ranged from 0.815 to 0.941, indicating good reproducibility. Optical intensity was lowest in the central area of retinal nerve fiber layer, ganglion cell layer, inner plexiform layer, inner nuclear layer, outer plexiform layer and photoreceptor layer, except for the retinal pigment epithelium (RPE). Optical intensity was positively correlated with image quality in all retinal layers (0.553<β<0.851, p<0.01), and negatively correlated with age in most retinal layers (-0.362<β<-0.179, p<0.01), except for the RPE (β = 0.456, p<0.01), outer nuclear layer and photoreceptor layer (p>0.05). There was no relationship between retinal optical intensity and sex, height, weight, SE, axial length, disc area and R/D area ratio. There was a specific pattern of distribution of retinal optical intensity in different regions. The optical intensity was affected by image quality and age. Image quality can be used as a reference for normalization. The effect of age needs to be taken into consideration when using OCT for diagnosis.

  19. Is there a link between passive smoke exposure and early-onset myopia in preschool Asian children?

    PubMed

    Chua, Sharon Yu Lin; Ikram, Mohammad Kamran; Tan, Chuen Seng; Stone, Richard A; Cai, Shirong; Gluckman, Peter D; Yap, Seng Chong; Yap, Fabian; Wong, Tien-Yin; Ngo, Cheryl S; Saw, Seang-Mei

    2016-07-01

    To investigate the association of passive tobacco smoke exposure with early-onset myopia among three-year-old children in Singapore. Pregnant mothers who attended their first trimester clinic at two major maternity units were recruited into the GUSTO birth cohort. The current analysis comprised 572 three-year-old children, who underwent cycloplegic autorefraction and axial length (AL) measurements. Myopia was defined as spherical equivalent (SE) of ≤-0.50 dioptres (D). Either parent completed questionnaires describing their child's exposure to passive smoke at six months, one and two years of age. There were 197 children (36.2%) who were exposed to passive smoke from birth to before six months. Compared to non-exposed children, children exposed to any passive smoke from birth to before six months experienced greater myopia prevalence (adjusted OR = 2.79; 95% CI: 1.24-6.29; p = 0.01). The odds of myopia in a child was greater if a smoker smokes at home, in the family car, or in the presence of the child (adjusted OR = 3.95; 95% CI: 1.41-11.09; p < 0.01) compared to non-exposed child. In contrast to myopia, childhood exposure to passive smoke did not systematically shift mean values for SE or AL. In this prospective birth cohort study, we found that childhood exposure to passive smoke from birth to before six months slightly increased the risk of early-onset myopia. This may indicate a delayed response to passive smoke exposure before six months and the development of myopia at three years of age. Our study is limited by the small number of myopic children at this young age. Thus, larger prospective studies using more objective cotinine level measures are required to fully establish and understand the influence of tobacco smoke on refractive development in older children. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.

  20. Pre- and Postcycloplegic Refractions in Children and Adolescents

    PubMed Central

    Zhu, Dan; Wang, Yan; Yang, Xianrong; Yang, Dayong; Guo, Kai; Guo, Yuanyuan; Jing, Xinxia; Pan, Chen-Wei

    2016-01-01

    Purpose To determine the difference between cycloplegic and non-cycloplegic refractive error and its associated factors in Chinese children and adolescents with a high prevalence of myopia. Methods A school-based study including 1565 students aged 6 to 21 years was conducted in 2013 in Ejina, Inner Mongolia, China. Comprehensive eye examinations were performed. Pre-and postcycloplegic refractive error were measured using an auto-refractor. For cycloplegic refraction, one drop of topical 1.0% cyclopentolate was administered to each eye twice with a 5-minute interval and a third drop was administered 15 minutes after the second drop if the pupil size was less than 6 mm or if the pupillary light reflex was still present. Results Two drops of cyclopentolate were found to be sufficient in 59% of the study participants while the other 41% need an additional drop. The prevalence of myopia was 89.5% in participants aged over 12 years and 68.6% in those aged 12 years or younger (P<0.001). When myopia was defined as spherical equivalent (SE) of less than -0.5 diopter (D), the prevalence estimates were 76.7% (95% confidence interval [CI] 74.6–78.8) and 54.1% (95%CI 51.6–56.6) before and after cycloplegic refraction, respectively. When hyperopia was defined as SE of more than 0.5D, the prevalence was only 2.8% (95%CI 1.9–3.6) before cycloplegic refraction while it was 15.5% (95%CI 13.7–17.3) after cycloplegic refraction. Increased difference between cycloplegic and non-cycloplegic refractive error was associated with decreased intraocular pressures (P = 0.01). Conclusions Lack of cycloplegia in refractive error measurement was associated with significant misclassifications in both myopia and hyperopia among Chinese children and adolescents. Decreased intraocular pressure was related to a greater difference between cycloplegic and non-cycloplegic refractive error. PMID:27907165

  1. Cycloplegic autorefraction versus subjective refraction: the Tehran Eye Study.

    PubMed

    Hashemi, Hassan; Khabazkhoob, Mehdi; Asharlous, Amir; Soroush, Sara; Yekta, AbbasAli; Dadbin, Nooshin; Fotouhi, Akbar

    2016-08-01

    To compare cycloplegic autorefraction with non-cycloplegic subjective refraction across all age and refractive error groups. In a cross-sectional study with random stratified cluster sampling, 160 clusters were chosen from various districts proportionate to the population of each district in Tehran. Following retinoscopy and autorefraction with the 0.25 D bracketing (Topcon KR-8000, Topcon, Tokyo, Japan), all participants had a subjective refraction. Then all participants underwent cycloplegic autorefraction. The final analysis was performed on 3482 participants with a mean age of 31.7 years (range 5-92 years). Based on cycloplegic and subjective refraction, mean spherical equivalent (SE) was +0.31±1.80 and -0.32±1.61 D, respectively (p<0.001). The 95% limits of agreement (LoA) between these two types of refraction were from -0.40 to 1.70 D. The largest difference between these two types of refraction was seen in the age group of 5-10 years (1.11±0.60 D), and the smallest difference was in the age group of >70 years (0.34±0.45 D). The 95% LoA was -0.52 to 0.89 D in patients with myopia and -0.12 to 2.04 D in patients with hyperopia. We found that female gender (coefficients=0.048), older age (coefficients=-0.247), higher education (coefficients=-0.043) and cycloplegic SE (coefficients=-0.472) significantly correlated with lower intermethod differences. The cycloplegic refraction is more sensitive than the subjective one to measure refractive error at all age groups especially in children and young adults. The cyclorefraction technique is highly recommended to exactly measure the refractive error in momentous conditions such as refractive surgery, epidemiological researches and amblyopia therapy, especially in hypermetropic eyes and paediatric cases. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  2. Pre- and Postcycloplegic Refractions in Children and Adolescents.

    PubMed

    Zhu, Dan; Wang, Yan; Yang, Xianrong; Yang, Dayong; Guo, Kai; Guo, Yuanyuan; Jing, Xinxia; Pan, Chen-Wei

    2016-01-01

    To determine the difference between cycloplegic and non-cycloplegic refractive error and its associated factors in Chinese children and adolescents with a high prevalence of myopia. A school-based study including 1565 students aged 6 to 21 years was conducted in 2013 in Ejina, Inner Mongolia, China. Comprehensive eye examinations were performed. Pre-and postcycloplegic refractive error were measured using an auto-refractor. For cycloplegic refraction, one drop of topical 1.0% cyclopentolate was administered to each eye twice with a 5-minute interval and a third drop was administered 15 minutes after the second drop if the pupil size was less than 6 mm or if the pupillary light reflex was still present. Two drops of cyclopentolate were found to be sufficient in 59% of the study participants while the other 41% need an additional drop. The prevalence of myopia was 89.5% in participants aged over 12 years and 68.6% in those aged 12 years or younger (P<0.001). When myopia was defined as spherical equivalent (SE) of less than -0.5 diopter (D), the prevalence estimates were 76.7% (95% confidence interval [CI] 74.6-78.8) and 54.1% (95%CI 51.6-56.6) before and after cycloplegic refraction, respectively. When hyperopia was defined as SE of more than 0.5D, the prevalence was only 2.8% (95%CI 1.9-3.6) before cycloplegic refraction while it was 15.5% (95%CI 13.7-17.3) after cycloplegic refraction. Increased difference between cycloplegic and non-cycloplegic refractive error was associated with decreased intraocular pressures (P = 0.01). Lack of cycloplegia in refractive error measurement was associated with significant misclassifications in both myopia and hyperopia among Chinese children and adolescents. Decreased intraocular pressure was related to a greater difference between cycloplegic and non-cycloplegic refractive error.

  3. Outcomes of Retreatment after Aborted Laser In Situ Keratomileusis due to Flap Complications

    PubMed Central

    Al-Mezaine, Hani S.; Al-Amro, Saleh A.; Al-Fadda, Abdulaziz; Al-Obeidan, Saleh

    2011-01-01

    Purpose: To determine the refractive outcomes and complications of retreatment after aborted primary laser in situ keratomileusis (LASIK) due to flap complications. Materials and Methods: This retrospective study evaluated 50 retreated eyes that had flap complications during primary LASIK at the Eye Consultants Center in Riyadh, Saudi Arabia. Data were analyzed for patients with at least 3 months follow-up post retreatment. Results: Thirty-three eyes of 31 consecutive patients with 3 months follow-up or later post retreatment were included. The primary LASIK was aborted due to incomplete flaps in 22 eyes (66.7%), buttonhole flaps in 7 eyes (21.2%), free partial flaps in 3 eyes (9.1%), and a free complete flap in 1 eye (3.0%). Twenty-two eyes (66.7%) were retreated with LASIK, and 11 eyes (33.3%) were retreated with surface ablation. The mean spherical equivalent (SE) was –0.23 ± 0.72 D, the mean astigmatism was –0.65 ± 0.89 D, and the mean loss of the best corrected visual acuity (BCVA) was 0.78 lines at the final postoperative visit. At the last postoperative visit, 20/30 or better BCVA was achieved in 90.1% of eyes that underwent retreatment with LASIK and in 91% of eyes that were retreated with surface ablation. There was no statistical difference in postoperative SE between eyes retreated with LASIK and eyes retreated with surface ablation (P = 0.610). There was no statistical difference in postoperative BCVA between eyes retreated with LASIK and those retreated with surface ablation (P = 0.756). There were no intraoperative complications and no eyes required a second retreatment. Conclusion: Creation of a flap after a previous intraoperative flap complication was not associated with any complications. The refractive outcomes of retreatment with LASIK or surface ablation were comparable and reasonably favorable. PMID:21887080

  4. A sample predictive model for intraocular pressure following laser in situ keratomileusis for myopia and an "intraocular pressure constant".

    PubMed

    Bahadir Kilavuzoglu, Ayse Ebru; Bozkurt, Tahir Kansu; Cosar, Cemile Banu; Sener, Asım Bozkurt

    2017-06-24

    To describe a sample predictive model for intraocular pressure (IOP) following laser in situ keratomileusis (LASIK) for myopia and an IOP constant. The records of patients that underwent LASIK for myopia and myopic astigmatism via WaveLight Allegretto Wave Eye-Q 400 Hz excimer laser and Hansatome XP microkeratome were retrospectively reviewed. Patients with no systemic or ocular disease other than myopia or myopic astigmatism were included in the study. Preoperative and postoperative month 1 data and intraoperative data were used to build the predictive model for IOP after LASIK. The IOP constant was calculated by subtracting the predicted IOP from preoperative IOP. The paired samples t test, Pearson's correlation analysis, curve estimation analysis, and linear regression analysis were used to evaluate the study data. The study included 425 eyes in 214 patients with a mean age of 32 ± 7.8 years. Mean spherical equivalent of the attempted correction (SE-ac) was -3.7 ± 1.7 diopters. Mean post-LASIK decrease in IOP was 4.6 ± 2.3 mmHg. The difference between preoperative and postoperative IOP was statistically significant (P < 0.001). SE-ac, preoperative IOP, and central corneal thickness had highly significant effects on postoperative IOP, based on linear regression analysis (P < 0.001 and R 2  = 0.043, P < 0.001 and R 2  = 0.370, and P < 0.001 and R 2  = 0.132, respectively). Regression model was created (F = 127.733, P < 0.001), and the adjusted R 2 value was 0.548. Evaluation of IOP after LASIK is important in myopic patients. The present study described a practical formula for predicting the true IOP with the aid of an IOP constant value in myopic eyes following LASIK.

  5. Posterior corneal surface differences between non-laser in situ keratomileusis (LASIK) and 10-year post-LASIK myopic eyes.

    PubMed

    Dai, Ma-Li; Wang, Qin-Mei; Lin, Zu-Shun; Yu, Ye; Huang, Jin-Hai; Savini, Giacomo; Zhang, Jia; Wang, Ling; Xu, Chen-Chen

    2018-03-01

    To evaluate the posterior corneal surface differences between non-laser in situ keratomileusis (LASIK) and 10-year post-LASIK myopic eyes. The study included 130 eyes from 65 patients, who were treated with myopic LASIK 10 years ago. In addition, 130 eyes from 65 unoperated myopic patients of matching present age and preoperative refraction were divided into control group. Data on the posterior corneal surface and anterior chamber were obtained from Pentacam software and compared between the groups. Postoperative visual acuity (VA) and refractive error were also analysed. The mean preoperative spherical equivalent (SE) was -6.99 ± 1.78 dioptre (D) in the LASIK group. Ten years after surgery, the mean SE was -0.45 ± 1.22 D, the efficacy index was 0.98, and the safety index was 1.01. The posterior corneal elevations of the LASIK group at 2 mm corneal diameter were significantly lower than those of the control group. However, posterior corneal elevations at 6 mm corneal diameter were higher in the LASIK group than the controls (p < 0.01 for all). The mean Q-values of posterior corneal surface demonstrated significant positive direction compared to that of control eyes at 6 and 7 mm corneal diameters (p < 0.05 for both). At the thinnest point of the cornea, the anterior chamber depths were shallower in the LASIK group than in controls. Meanwhile, the anterior chamber volumes (ACV) were smaller in the LASIK group than in the control group. Our results demonstrated that the posterior corneal surface tends to show signs of central flattening and peripheral steepening 10 years after myopic LASIK surgery compared to that of non-operated myopic eyes. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  6. Combined laser in situ keratomileusis and prophylactic high-fluence corneal collagen crosslinking for high myopia: two-year safety and efficacy.

    PubMed

    Kanellopoulos, Anastasios John; Asimellis, George

    2015-07-01

    To evaluate the safety, efficacy, and refractive and keratometric stability of myopic femtosecond laser in situ keratomileusis (LASIK) with concurrent prophylactic high-fluence corneal collagen crosslinking (CXL) compared with the outcomes of standard femtosecond LASIK. Private clinical practice, Athens, Greece. Consecutive randomized prospective comparative study. Eyes that had myopic LASIK or myopic LASIK with concurrent high-fluence CXL were evaluated preoperatively and up to 2 years postoperatively for manifest refraction spherical equivalent (MRSE), refractive astigmatism, visual acuity, corneal keratometry (K), and endothelial cell count. One hundred forty consecutive eyes had myopic LASIK; 65 of the eyes were treated additionally with CXL. In the LASIK-CXL eyes, the mean postoperative MRSE was -0.18 diopter (D) ± 17.0 (SD) from -6.67 ± 2.14 D preoperatively. The postoperative flat K was 37.67 D from 43.92 D, and the steep K was 38.38 D from 45.15 D. The correlation coefficient of SE correction predictability was 0.975. In the LASIK-only eyes, the mean postoperative MRSE was -0.32 ± 0.24 D from -5.49 ± 1.99 D preoperatively. The flat K was 38.04 D from 43.15 D, and the steep K was 38.69 D from 44.03 D. The correlation coefficient of SE correction predictability was 0.968. The differences between the 2 groups at the 20/20 and 20/25 levels were statistically significant (P = .045 and P = .039, respectively). Two-year results indicate that the application of prophylactic CXL concurrently with high-myopic LASIK appears to improve refractive and keratometric stability, presumably by affecting corneal biomechanical properties. Dr. Kanellopoulos is a consultant to Alcon Surgical, Inc., Wavelight Laser Technologie AG, Allergan, Inc., Avedro, Inc., and i-Optics Corp. Dr. Asimellis has no financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Combined intrastromal astigmatic keratotomy and laser in situ keratomileusis flap followed by photoablation to correct post-penetrating keratoplasty ametropia and high astigmatism: One-year follow-up.

    PubMed

    Shalash, Riad B; Elshazly, Malak I; Salama, Marwa M

    2015-10-01

    To evaluate a new technique combining intrastromal astigmatic keratotomy (AK) with a laser in situ keratomileusis (LASIK) flap followed by excimer laser photoablation to correct post-penetrating keratoplasty (PKP) high astigmatism and ametropia. Kasr El Aini Hospital, Cairo University, Cairo, Egypt. Prospective interventional uncontrolled case series. Patients with post-PKP high astigmatism and ametropia had paired intrastromal AK with LASIK flap using the M2 microkeratome followed 2 to 3 months later by excimer laser photoablation. The main outcome measures were uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), mean refractive spherical equivalent (SE), and mean cylinder after each step and at the 1-year follow-up. The study comprised 20 eyes (20 patients). All parameters were significantly improved in all patients by the last follow-up visit. The mean UDVA improved from 1.07 logMAR ± 0.2 (SD) preoperatively to 0.23 ± 0.18 logMAR (P < .001), the mean CDVA improved from 0.79 ± 0.18 logMAR to 0.12 ± 0.12 logMAR (P < .001), the mean refractive SE improved from -5.04 ± 2.62 diopters (D) to -1.47 ± 1.32 D (P = .001), and the mean cylinder reduced from -5.39 ± 0.98 D to -1.05 ± 0.71 D (P < .001). The mean correction index was 0.84 ± 0.10, and the mean flattening index was 0.83 ± 0.10. Thirty-five percent of cases developed microperforations, and 15% developed epithelial ingrowth. This combined approach allowed for the correction of high astigmatism and ametropia following PKP; however, epithelial ingrowth requiring intervention is a complication to be considered. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Lens power in Iranian schoolchildren: a population-based study.

    PubMed

    Hashemi, Hassan; Pakzad, Reza; Iribarren, Rafael; Khabazkhoob, Mehdi; Emamian, Mohammad Hassan; Fotouhi, Akbar

    2018-06-01

    To evaluate lens power (LP) in schoolchildren aged 6-12 years. This cross-sectional study was conducted in Shahroud, northeast Iran. The students were selected through random cluster sampling and underwent the measurements of biometry, uncorrected and corrected visual acuity, non-cycloplegic and cycloplegic refraction. The LP was calculated using the Bennett formula. Of 6624 invited children, 5620 (84.8%) participated in the study and data of 4870 children were finally analysed. The mean age of the participants was 9.7 years and 2277 participants (46.02%) were girls. The mean LPs were 22.86 dioptres (D) in total study population, 23.91 D in 6 and 22.10 D in 12-year-old children. The mean LP was higher in girls than boys (23.48 D vs 22.34 D), in rural children than urban children (23.17 D vs 22.83 D) and in children with hyperopia (23.25 D) than children with myopia or emmetropia (22.64 D and 22.86 D, respectively). In the multiple linear regression model, lens thickness (β=1.59, p<0.001), anterior chamber depth (β=2.21, p<0.001) and female sex (β=0.016, p=0.015) were associated with an increase in the LP, while axial length (AL) (β=-4.41, p<0.001), corneal power (CP) (β=-1.47, p<0.001), spherical equivalent (SE) (β=-1.50, p<0.001) and age (β=-0.005, p=0.001) were associated with a decrease in the LP. AL and sex had the highest and lowest impact on LP, respectively. LP decreased with age between 6 and 12 years and was associated with a shorter AL, deeper ACD, higher SE, thicker lens and lower CP. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. Pickett angles and Cremer-Pople coordinates as collective variables for the enhanced sampling of six-membered ring conformations

    NASA Astrophysics Data System (ADS)

    Sega, M.; Autieri, E.; Pederiva, F.

    2011-01-01

    Although completely equivalent for the description of puckered ring conformers, the two popular coordinates sets of Strauss-Pickett dihedral angles and Cremer-Pople spherical coordinates are shown to have contrasting features when employed as collective variables in free-energy calculations with accelerated sampling techniques. Results from a 100 ns molecular dynamics simulation at conformational equilibrium and from combined metadynamics/umbrella sampling calculations of glucose are exploited to elucidate these differences.

  10. General Relativity

    NASA Astrophysics Data System (ADS)

    Hobson, M. P.; Efstathiou, G. P.; Lasenby, A. N.

    2006-02-01

    1. The spacetime of special relativity; 2. Manifolds and coordinates; 3. Vector calculus on manifolds; 4. Tensor calculus on manifolds; 5. Special relativity revisited; 6. Electromagnetism; 7. The equivalence principle and spacetime curvature; 8. The gravitational field equations; 9. The Schwarzschild geometry; 10. Experimental tests of general relativity; 11. Schwarzschild black holes; 12. Further spherically-symmetric geometries; 13. The Kerr geometry; 14. The Friedmann-Robertson-Walker geometry; 15. Cosmological models; 16. Inflationary cosmology; 17. Linearised general relativity; 18. Gravitational waves; 19. A variational approach to general relativity.

  11. Primary angle closure glaucoma in a myopic kinship.

    PubMed

    Hagan, J C; Lederer, C M

    1985-03-01

    Three related myopic individuals with primary angle closure glaucoma are reported. They had true myopia and not pseudomyopia secondary to increased lenticular index of refraction. We believe one of these individuals (-8.62 spherical equivalent) to have the most myopic case of primary angle closure glaucoma reported in the literature. Although myopia is associated with anatomical factors that offer considerable protection from primary angle closure glaucoma, its presence does not eliminate the possibility of this disease. Laser iridectomy was effective in the treatment of these patients.

  12. A method of inversion of satellite magnetic anomaly data

    NASA Technical Reports Server (NTRS)

    Mayhew, M. A.

    1977-01-01

    A method of finding a first approximation to a crustal magnetization distribution from inversion of satellite magnetic anomaly data is described. Magnetization is expressed as a Fourier Series in a segment of spherical shell. Input to this procedure is an equivalent source representation of the observed anomaly field. Instability of the inversion occurs when high frequency noise is present in the input data, or when the series is carried to an excessively high wave number. Preliminary results are given for the United States and adjacent areas.

  13. Hamiltonian 3-D Ray Tracing in the Oceanic Waveguide on the Ellipsoidal Earth

    DTIC Science & Technology

    1990-12-01

    equivalent to Eq. (B 1). I The ionosphere has a uniform refractive index (the isovelocity acoustic analogue) in this con- Using the ray invariant (the...spherical coordinates in NOAA’s 3-D ray tracer HARPO, are adapted to ellipsoidal coordinates in the oceanic waveguide. The ensuing modified HARPO is used to...objective of this modeling is to extract the predictable part of the travel-time trend and fluctua- tions along several long paths that will be used to

  14. Classical dynamics on curved Snyder space

    NASA Astrophysics Data System (ADS)

    Ivetić, B.; Meljanac, S.; Mignemi, S.

    2014-05-01

    We study the classical dynamics of a particle in nonrelativistic Snyder-de Sitter space. We show that for spherically symmetric systems, parameterizing the solutions in terms of an auxiliary time variable, which is a function only of the physical time and of the energy and angular momentum of the particles, one can reduce the problem to the equivalent one in classical mechanics. We also discuss a relativistic extension of these results, and a generalization to the case in which the algebra is realized in flat space.

  15. Neuronal adaptation to simulated and optically-induced astigmatic defocus.

    PubMed

    Ohlendorf, Arne; Tabernero, Juan; Schaeffel, Frank

    2011-03-25

    It is well established that spatial adaptation can improve visual acuity over time in the presence of spherical defocus. It is less well known how far adaptation to astigmatic defocus can enhance visual acuity. We adapted subjects to "simulated" and optically-induced "real" astigmatic defocus, and studied how much they adapt and how selective adaptation was for the axis of astigmatism. Ten subjects with a mean age of 26.7±2.4years (range 23-30) were enrolled in the study, three of them myopic (average spherical equivalent (SE)±SD: -3.08±1.42D) and seven emmetropic (average SE±SD: -0.11±0.18D). All had a corrected minimum visual acuity (VA) of logVA 0.0. For adaptation, subjects watched a movie at 4m distance for 10min that was convolved frame-by-frame with an astigmatic point spread function, equivalent to +3D defocus, or they watched an unfiltered movie but with spectacle frames with a 0/+3D astigmatic trial lenses. Subsequently, visual acuity was determined at the same distance, using high contrast letter acuity charts. Four experiments were performed. In experiment (1), simulated astigmatic defocus was presented both for adaptation and testing, in experiment (2) optically-induced astigmatic defocus was presented both for adaptation and testing of visual acuity. In all these cases, the +3D power meridian was at 0°. In experiments (3) and (4), the +3D power meridian was at 0° during adaptation but rotated to 90° during testing. Astigmatic defocus was simulated in experiment (3) but optically-induced in experiment (4). Experiments 1 and 2: adaptation to either simulated or real astigmatic defocus increased visual acuity in both test paradigms, simulated (change in VA 0.086±0.069 log units; p<0.01) and lens-induced astigmatic defocus (change in VA 0.068±0.031 log units; p<0.001). Experiments 3 and 4: when the axis was rotated, the improvement in visual acuity failed to reach significance, both for simulated (change in VA 0.042±0.079 log units; p=0.13) and lens-induced astigmatic defocus (change in VA 0.038±0.086 log units; p=0.19). Adaptation to astigmatic defocus occurs for both simulated and real defocus, and the effects of adaptation seem to be selective for the axis of astigmatism. These observations suggest that adaptation involves a re-adjustment of the spatial filters selectively for astigmatic meridians, although the underlying mechanism must be more complicated than just changes in shapes of the receptive fields of retinal or cortical neurons. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Optical nonlinearity of CdSe-PMMA hybrid nanocomposite investigated via Z-scan technique and semi-empirical relations

    NASA Astrophysics Data System (ADS)

    Kaur, Ramneek; Tripathi, S. K.

    2016-04-01

    CdSe-PMMA nanocomposite has been synthesized by ex-situ technique. The effect of different Ag doping concentrations on its structural and optical properties has been studied. X-ray diffraction reveals the hexagonal wurtzite structure of the polymer nanocomposites with preferential growth of the nanocrystals along (1 0 0) direction. Transmission electron micrograph shows the spherical CdSe nanoparticles embedded in polymer matrix. The nonlinear refractive index of the nanocomposites has been calculated using Tichy & Ticha semi-empirical relations and Z-scan technique. Z-scan results disclose the two photon absorption process in the hybrid nanocomposites with self focussing behaviour. With Ag doping, the nonlinearity is found to be increased up to 0.2% Ag doping concentration due to the confined effect of Surface Plasmon, Quantum confinement and thermal lensing. Above 0.2% Ag concentration, its value decreases due to the declined linear refractive index of the nanocomposites. Maximum two photon figure of merit is 76 for 0.2% Ag doped CdSe-PMMA hybrid nanocomposite. The present results accentuate the possibility of tuning the optical non-linearity of CdSe-PMMA hybrid nanocomposite by adjusting the doping concentration.

  17. Racial Variations in the Prevalence of Refractive Errors in the United States: The Multi-Ethnic Study of Atherosclerosis

    PubMed Central

    PAN, CHEN-WEI; KLEIN, BARBARA E.K.; COTCH, MARY FRANCES; SHRAGER, SANDI; KLEIN, RONALD; FOLSOM, AARON; KRONMAL, RICHARD; SHEA, STEVEN J.; BURKE, GREGORY L.; SAW, SEANG-MEI; WONG, TIEN Y.

    2013-01-01

    PURPOSE To describe racial variations in the prevalence of refractive errors among adult white, Chinese, Hispanic, and black subjects in the United States. DESIGN Cross-sectional data from a prospective cohort study—the Multi-Ethnic Study of Atherosclerosis (MESA). METHODS A total of 6000 adults aged 45 to 84 years living in the United States participated in the study. Refractive error was assessed, without cycloplegia, in both eyes of all participants using an autorefractor. After excluding eyes with cataract, cataract surgery, or previous refractive surgery, the eye with the larger absolute spherical equivalent (SE) value for each participant was used to classify refractive error. Any myopia was defined as SE of −1.0 diopters (D) or less; high myopia was defined as SE of −5.0 D or less; any hyperopia was defined as SE of +1.0 D or more; clinically significant hyperopia was defined as SE of +3.0 D or more. Astigmatism was defined as a cylinder value of +1.0 D or more. RESULTS After excluding 508 participants with cataracts in both eyes, 838 participants with cataract surgery, 90 participants with laser refractive surgery, and 134 participants who refused to remove their contact lenses for the refraction measurement, 4430 adults with refractive error assessment in at least 1 eye contributed to the analysis. The prevalence of myopia among MESA participants was 25.1%, with lowest rates in Hispanic participants (14.2%), followed by black (21.5%) and white participants (31.0%), and highest rates in Chinese participants (37.2%). The overall rates of high myopia and astigmatism were 4.6% and 45.0%, respectively, with Chinese subjects also having the highest rates of high myopia (11.8%) and astigmatism (53.4%). The overall prevalence of any hyperopia was 38.2% and clinically significant hyperopia was 6.1%, with Hispanic participants having the highest rates of hyperopia (50.2%) and clinically significant hyperopia (8.8%). In multivariate analyses adjusting for age, sex, race, and study site, higher education level, being employed, and being taller were associated with a higher prevalence of myopia. In contrast, lower educational level and being shorter were associated with a higher prevalence of hyperopia. CONCLUSIONS Myopia and astigmatism were most prevalent in the Chinese population, with Chinese subjects having 3 times the prevalence of myopia as Hispanic subjects. Hyperopia was most common in Hispanic subjects. These findings provide further insights into variations in refractive errors among different racial groups and have important implications for the eye care services in the United States. PMID:23453694

  18. Racial variations in the prevalence of refractive errors in the United States: the multi-ethnic study of atherosclerosis.

    PubMed

    Pan, Chen-Wei; Klein, Barbara E K; Cotch, Mary Frances; Shrager, Sandi; Klein, Ronald; Folsom, Aaron; Kronmal, Richard; Shea, Steven J; Burke, Gregory L; Saw, Seang-Mei; Wong, Tien Y

    2013-06-01

    To describe racial variations in the prevalence of refractive errors among adult white, Chinese, Hispanic, and black subjects in the United States. Cross-sectional data from a prospective cohort study-the Multi-Ethnic Study of Atherosclerosis (MESA). A total of 6000 adults aged 45 to 84 years living in the United States participated in the study. Refractive error was assessed, without cycloplegia, in both eyes of all participants using an autorefractor. After excluding eyes with cataract, cataract surgery, or previous refractive surgery, the eye with the larger absolute spherical equivalent (SE) value for each participant was used to classify refractive error. Any myopia was defined as SE of -1.0 diopters (D) or less; high myopia was defined as SE of -5.0 D or less; any hyperopia was defined as SE of +1.0 D or more; clinically significant hyperopia was defined as SE of +3.0 D or more. Astigmatism was defined as a cylinder value of +1.0 D or more. After excluding 508 participants with cataracts in both eyes, 838 participants with cataract surgery, 90 participants with laser refractive surgery, and 134 participants who refused to remove their contact lenses for the refraction measurement, 4430 adults with refractive error assessment in at least 1 eye contributed to the analysis. The prevalence of myopia among MESA participants was 25.1%, with lowest rates in Hispanic participants (14.2%), followed by black (21.5%) and white participants (31.0%), and highest rates in Chinese participants (37.2%). The overall rates of high myopia and astigmatism were 4.6% and 45.0%, respectively, with Chinese subjects also having the highest rates of high myopia (11.8%) and astigmatism (53.4%). The overall prevalence of any hyperopia was 38.2% and clinically significant hyperopia was 6.1%, with Hispanic participants having the highest rates of hyperopia (50.2%) and clinically significant hyperopia (8.8%). In multivariate analyses adjusting for age, sex, race, and study site, higher education level, being employed, and being taller were associated with a higher prevalence of myopia. In contrast, lower educational level and being shorter were associated with a higher prevalence of hyperopia. Myopia and astigmatism were most prevalent in the Chinese population, with Chinese subjects having 3 times the prevalence of myopia as Hispanic subjects. Hyperopia was most common in Hispanic subjects. These findings provide further insights into variations in refractive errors among different racial groups and have important implications for the eye care services in the United States. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Direct synthesis of all-inorganic heterostructured CdSe/CdS QDs in aqueous solution for improved photocatalytic hydrogen generation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Zhi-Jun; Fan, Xiang-Bing; Li, Xu-Bing

    2017-01-01

    Here we present a facile aqueous approach to synthesize heterostructured CdSe/CdS QDs with all-inorganic chalcogenide S2- ligands under mild conditions. High-resolution transmission electron microscopy (HRTEM), X-ray diffraction (XRD), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), and steady-state emission spectroscopy demonstrate that the heterostructured CdSe/CdS QDs with sulfur-rich surface composition are formed by heterogeneous nucleation of Cd2+ and S2- precursors on the CdSe QDs. After adsorption of small Ni(OH)(2) clusters over the surface in situ, the CdSe/CdS-Ni(OH)(2) photocatalyst enables H-2 production efficiently with an internal quantum yield of 52% under visible light irradiation at 455 nm, up to an 8-fold increase ofmore » activity to that of spherical CdSe QDs-Ni(OH)(2) under the same conditions. Femtosecond transient absorption spectroscopy, X-ray transient absorption (XTA) spectroscopy, steady-state and time-resolved emission spectroscopy show that the quasi-type-II band alignment in the CdSe/CdS heterostructure is responsible for the efficiency enhancement of light harvesting and surface/interfacial charge separation in solar energy conversion. The unprecedented results exemplify an easily accessible pattern of aqueous synthesis of all-inorganic heterostructured QDs for advanced photosynthetic H-2 evolution.« less

  20. The effect of the Z mutation on the ability of alpha 1-antitrypsin to prevent neutrophil mediated tissue damage.

    PubMed

    Llewellyn-Jones, C G; Lomas, D A; Carrell, R W; Stockley, R A

    1994-11-29

    Recent studies have shown that alpha 1-antitrypsin (alpha 1-AT) from Z antitrypsin deficiency subjects has a slightly lower association rate constant with neutrophil elastase (NE) than alpha 1-AT from normal subjects, although it is unknown whether this is of clinical importance. We have purified alpha 1-AT from a normal (M alpha 1-AT) and from a deficient (Z alpha 1-AT) subject and have confirmed that the association rate constants for NE are different (5.28; S.E. 0.06.10(7) M-1 s-1 and 1.2; S.E. 0.2.10(7) M-1 s-1, respectively). We have assessed the ability of both of these proteins to inhibit neutrophil mediated fibronectin (FN) degradation in vitro. Both proteins inhibited FN degradation in a dose dependant manner although Z alpha 1-AT was less effective than M alpha 1-AT at equivalent concentrations of active inhibitor (P < 0.05). Inhibition by M alpha 1-AT was 28.5% S.E. 3.9 at 0.01 microM; 35.5% S.E. 7.3 at 0.1 microM and 37% S.E. 8.4 at 0.5 microM, whereas inhibition by Z alpha 1-AT was 9.25% S.E. 3.9; 19.25% S.E. 7.7 and 21.2% S.E. 9.7, respectively. When the time course of inhibition of FN degradation was studied the difference (although less at 1.0 microM) became greater over the 3 h period of the assay. These results suggest that Z alpha 1-AT is less able than the M phenotype to inhibit connective tissue degradation by neutrophils at equivalent concentrations. This is probably due to the lower association rate constant although the reduced stability of the Z molecule may play a role. The differences, together with the reduced plasma concentration, may accentuate the susceptibility of deficient subjects to the development of emphysema.

  1. Decomposition of the Multistatic Response Matrix and Target Characterization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chambers, D H

    2008-02-14

    Decomposition of the time-reversal operator for an array, or equivalently the singular value decomposition of the multistatic response matrix, has been used to improve imaging and localization of targets in complicated media. Typically, each singular value is associated with one scatterer even though it has been shown in several cases that a single scatterer can generate several singular values. In this paper we review the analysis of the time-reversal operator (TRO), or equivalently the multistatic response matrix (MRM), of an array system and a small target. We begin with two-dimensional scattering from a small cylinder then show the results formore » a small non-spherical target in three dimensions. We show that the number and magnitudes of the singular values contain information about target composition, shape, and orientation.« less

  2. Metal-cluster ionization energy: A profile-insensitive exact expression for the size effect

    NASA Astrophysics Data System (ADS)

    Seidl, Michael; Perdew, John P.; Brajczewska, Marta; Fiolhais, Carlos

    1997-05-01

    The ionization energy of a large spherical metal cluster of radius R is I(R)=W+(+c)/R, where W is the bulk work function and c~-0.1 is a material-dependent quantum correction to the electrostatic size effect. We present 'Koopmans' and 'displaced-profile change-in-self-consistent-field' expressions for W and c within the ordinary and stabilized-jellium models. These expressions are shown to be exact and equivalent when the exact density profile of a large neutral cluster is employed; these equivalences generalize the Budd-Vannimenus theorem. With an approximate profile obtained from a restricted variational calculation, the 'displaced-profile' expressions are the more accurate ones. This profile insensitivity is important, because it is not practical to extract c from solutions of the Kohn-Sham equations for small metal clusters.

  3. Induced Higher-order aberrations after Laser In Situ Keratomileusis (LASIK) Performed with Wavefront-Guided IntraLase Femtosecond Laser in moderate to high Astigmatism.

    PubMed

    Al-Zeraid, Ferial M; Osuagwu, Uchechukwu L

    2016-03-22

    Wavefront-guided Laser-assisted in situ keratomileusis (LASIK) is a widespread and effective surgical treatment for myopia and astigmatic correction but whether it induces higher-order aberrations remains controversial. The study was designed to evaluate the changes in higher-order aberrations after wavefront-guided ablation with IntraLase femtosecond laser in moderate to high astigmatism. Twenty-three eyes of 15 patients with moderate to high astigmatism (mean cylinder, -3.22 ± 0.59 dioptres) aged between 19 and 35 years (mean age, 25.6 ± 4.9 years) were included in this prospective study. Subjects with cylinder ≥ 1.5 and ≤2.75 D were classified as moderate astigmatism while high astigmatism was ≥3.00 D. All patients underwent a femtosecond laser-enabled (150-kHz IntraLase iFS; Abbott Medical Optics Inc) wavefront-guided ablation. Uncorrected (UDVA), corrected (CDVA) distance visual acuity in logMAR, keratometry, central corneal thickness (CCT) and higher-order aberrations (HOAs) over a 6 mm pupil, were assessed before and 6 months, postoperatively. The relationship between postoperative change in HOA and preoperative mean spherical equivalent refraction, mean astigmatism, and postoperative CCT were tested. At the last follow-up, the mean UDVA was increased (P < 0.0001) but CDVA remained unchanged (P = 0.48) and no eyes lost ≥2 lines of CDVA. Mean spherical equivalent refraction was reduced (P < 0.0001) and was within ±0.50 D range in 61% of eyes. The average corneal curvature was flatter by 4 D and CCT was reduced by 83 μm (P < 0.0001, for all), postoperatively. Coma aberrations remained unchanged (P = 0.07) while the change in trefoil (P = 0.047) postoperatively, was not clinically significant. The 4th order HOAs (spherical aberration and secondary astigmatism) and the HOA root mean square (RMS) increased from -0.18 ± 0.07 μm, 0.04 ± 0.03 μm and 0.47 ± 0.11 μm, preoperatively, to 0.33 ± 0.19 μm (P = 0.004), 0.21 ± 0.09 μm (P < 0.0001) and 0.77 ± 0.27 μm (P < 0.0001), six months postoperatively. The change in spherical aberration after the procedure increased with an increase in the degree of preoperative myopia. Wavefront-guided IntraLASIK offers a safe and effective option for vision and visual function improvement in astigmatism. Although, reduction of HOA is possible in a few eyes, spherical-like aberrations are increased in majority of the treated eyes.

  4. Peripheral refraction and higher-order aberrations with cycloplegia and fogging lenses using the BHVI-EyeMapper

    PubMed Central

    Bakaraju, Ravi Chandra; Fedtke, Cathleen; Ehrmann, Klaus; Falk, Darrin; Thomas, Varghese; Holden, Brien Anthony

    2015-01-01

    Purpose To determine if a fogging lens ameliorates accommodative effects driven by the closed-view design of the BHVI-EyeMapper (EM) instrument. We compared cycloplegic refraction and higher-order aberration measurements of the EM with those obtained with a fogging lens. Methods Twenty-six, young, participants (15F, 25 ± 5 years, range: 18–35 years, SE: +0.25 D and −3.50 D) with good ocular health were recruited. Five independent measurements of on- and off-axis refraction and higher-order aberrations were recorded across the horizontal visual field, under two conditions: non-cycloplegic measurements with +1.00 D fogging lens and cycloplegia, always in the same sequence. The contralateral eye was occluded during the measurements. Two drops of 1% Tropicamide delivered within 5 min facilitated cycloplegic measurements. All participants were refracted 30 min after installation of the second drop. Results Mean spherical equivalent measures of the non-cycloplegic condition were significantly more myopic than their cycloplegic counterparts (p < 0.05); approximately by 0.50 D centrally, increasing to 1.00 D towards the periphery. The horizontal astigmatic component, J180, demonstrated small but statistically significant differences between the test conditions. Differences were predominant for eccentricities greater than 30°, in both nasal and temporal meridians. The oblique astigmatic component, J45, was not significantly different between the test conditions. The primary spherical aberration coefficient C(4, 0) was significantly less positive for the non-cycloplegic state than its cycloplegic counterpart. This result held true across the entire horizontal visual field. The horizontal coma and trefoil coefficients C(3, 1) and C(3, 3) were not significantly different between the two conditions. Conclusions The use of +1.00 D fogging lens without cycloplegia did not provide complete relaxation of accommodation. The discrepancies between cycloplegic and non-cycloplegic EM measurements were found to be more pronounced for peripheral field angles than central measures, for both M and J180 components. PMID:26190684

  5. Peripheral refraction and higher-order aberrations with cycloplegia and fogging lenses using the BHVI-EyeMapper.

    PubMed

    Bakaraju, Ravi Chandra; Fedtke, Cathleen; Ehrmann, Klaus; Falk, Darrin; Thomas, Varghese; Holden, Brien Anthony

    2016-01-01

    To determine if a fogging lens ameliorates accommodative effects driven by the closed-view design of the BHVI-EyeMapper (EM) instrument. We compared cycloplegic refraction and higher-order aberration measurements of the EM with those obtained with a fogging lens. Twenty-six, young, participants (15F, 25±5 years, range: 18-35 years, SE: +0.25 D and -3.50 D) with good ocular health were recruited. Five independent measurements of on- and off-axis refraction and higher-order aberrations were recorded across the horizontal visual field, under two conditions: non-cycloplegic measurements with +1.00 D fogging lens and cycloplegia, always in the same sequence. The contralateral eye was occluded during the measurements. Two drops of 1% Tropicamide delivered within 5 min facilitated cycloplegic measurements. All participants were refracted 30 min after installation of the second drop. Mean spherical equivalent measures of the non-cycloplegic condition were significantly more myopic than their cycloplegic counterparts (p<0.05); approximately by 0.50 D centrally, increasing to 1.00 D towards the periphery. The horizontal astigmatic component, J180, demonstrated small but statistically significant differences between the test conditions. Differences were predominant for eccentricities greater than 30°, in both nasal and temporal meridians. The oblique astigmatic component, J45, was not significantly different between the test conditions. The primary spherical aberration coefficient C(4, 0) was significantly less positive for the non-cycloplegic state than its cycloplegic counterpart. This result held true across the entire horizontal visual field. The horizontal coma and trefoil coefficients C(3, 1) and C(3, 3) were not significantly different between the two conditions. The use of +1.00 D fogging lens without cycloplegia did not provide complete relaxation of accommodation. The discrepancies between cycloplegic and non-cycloplegic EM measurements were found to be more pronounced for peripheral field angles than central measures, for both M and J180 components. Copyright © 2015 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  6. Structural and morphological study of chemically synthesized CdSe thin films

    NASA Astrophysics Data System (ADS)

    Agrawal, P.; Singh, Randhir; Sharma, Jeewan; Sachdeva, M.; Singh, Anupinder; Bhargava, A.

    2018-05-01

    Nanocrystalline CdSe thin films were prepared by Chemical Bath Deposition (CBD) method using potassium nitrilo-triacetic acid cadmium complex and sodium selenosulphite. The as deposited films were red in color, uniform and well adherent to the glass substrate. These films were strongly dependent on the deposition parameters such as bath composition, deposition temperature and time. Films were annealed at 350 °C for four hours. The morphological, structural and optical properties were studied using X-ray diffraction (XRD), UV-VIS spectrophotometer measurements, scanning electron microscopy and atomic force microscopy. The XRD analysis confirmed that films are predominantly in hexagonal phase. Scanning electron micrograph shows that the grains are uniformly spread all over the film and each grain contains many nanocrystals with spherical shapes.

  7. Nano selenium as antioxidant agent in a multilayer food packaging material.

    PubMed

    Vera, Paula; Echegoyen, Yolanda; Canellas, Elena; Nerín, Cristina; Palomo, María; Madrid, Yolanda; Cámara, Carmen

    2016-09-01

    Selenium nanoparticles (SeNPs) were incorporated in a flexible multilayer plastic material using a water-base adhesive as vehicle for SeNPs. The antioxidant performance of the original solutions containing spherical SeNPs of 50-60 nm diameter, the adhesive containing these SeNPs, and the final multilayer plastic material to be used as food packaging were quantitatively measured. The radical scavenging capacity due to SeNPs was quantified by a free radical assay developed in the laboratory and by the diphenyl-1-picrylhydrazyl (DPPH) method. DPPH was not efficient to measure the scavenging capacity in the multilayer when the free radical scavenger is not in the surface in contact with it. Several multilayer laminated structures composed by [PET (20 m)-adhesive-LDPE (with variable thickness from 35 to 90 μm)] were prepared and measured, demonstrating for the first time that free radicals derived from oxygen (OH·, O2·, and O2H) cross the PE layer and arrive at the adhesive. SeNPs remain as such after manufacture and the final laminate is stable after 3 months of storage. The antioxidant multilayer is a non-migrating efficient free radical scavenger, able to protect the packaged product versus oxidation and extending the shelf life without being in direct contact with the product. Migration tests of both Se and SeNPs to simulants and hazelnuts demonstrated the non-migrating performance of this new active packaging. Graphical abstract ᅟ.

  8. Simple synthesis of PbSe nanocrystals and their self-assembly into 2D ‘flakes’ and 1D ‘ribbons’ structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Díaz-Torres, E., E-mail: ediaz@cinvestav.mx; Ortega-López, M.; Matsumoto, Y.

    2016-08-15

    Highlights: • PbSe is obtained in a simple way by the co-precipitation method at low-temperature. • The structural, morphological and optical properties of PbSe were studied. • Adding NH{sub 4}OH to the precursor solutions influences on the morphology. • 2D- and 1D-PbSe structures assemble by oriented attachment. • PbSe can be a potential candidate for thermoelectric applications. - Abstract: This work presents a simple and low-temperature method to prepare a variety of Lead selenide (PbSe) nanostructures, using aqueous solutions of Pb(NO{sub 3}){sub 2} and NaHSe. Nanostructures with different morphology were obtained by varying the Pb:Se molar ratio, as well asmore » the mixing sequence of NH{sub 4}OH with either Pb(NO{sub 3}){sub 2} or NaHSe. Nanoparticles with different shapes (spherical and octahedral), and self-assembled structures (flakes and ribbons) were observed by Transmission Electron Microscopy. X-ray results confirmed that the PbSe rock-salt crystalline structure was obtained for all of the prepared samples. The crystal size is in the order of 7.3 to 8.9 nm for single nanocrystals. The absorption spectra of the samples show exciton absorption bands at 1395 nm and 1660 nm. This material could be used to develop more advanced structures for thermoelectric generators.« less

  9. Optical aberrations induced by subclinical decentrations of the ablation pattern

    NASA Astrophysics Data System (ADS)

    Mrochen, Michael; Kaemmerer, Maik; Riedel, Peter; Mierdel, Peter; Krinke, Hans-Eberhard; Seiler, Theo

    2000-06-01

    Purpose: The aim of this work was to study the effect of currently used ablation profiles along with eccentric ablations on the increase of higher order aberrations observed after PRK. Material and Methods: The optical aberrations of 10 eyes were tested before and after PRK. Refractive surgery was performed using a ArF-excimer laser system. In all cases, the ablation zone was 6 mm or larger. The spherical equivalent of the correction was ranging from -2.5 D to -6.0 D. The measured wavefront error was compared to numerical simulations done with the reduced eye model and currently used ablation profiles as well as compared with experimental results obtained from ablation on PMMA balls. Results: The aberration measurements result in a considerable change of the spherical- and coma-like wavefront errors. This result was in good correlation with the numerical simulations and the experimental results. Furthermore, it has been derived that the major contribution on the induced higher order aberrations are a result of the small decentration (less than 1.0 mm) of the ablation zone. Conclusions: Higher order spherical- and coma-like aberrations after PRK are mainly determined by the decentration of the ablation zone during laser refractive surgery. However, future laser systems should use efficient eye-tracking systems and aspherical ablation profiles to overcome this problem.

  10. Analysis of various factors affecting pupil size in patients with glaucoma.

    PubMed

    Park, Ji Woong; Kang, Bong Hui; Kwon, Ji Won; Cho, Kyong Jin

    2017-09-16

    Pupil size is an important factor in predicting post-operative satisfaction. We assessed the correlation between pupil size, measured by Humphrey static perimetry, and various affecting factors in patients with glaucoma. In total, 825 eyes of 415 patients were evaluated retrospectively. Pupil size was measured with Humphrey static perimetry. Comparisons of pupil size according to the presence of glaucoma were evaluated, as were correlations between pupil size and various factors, including age, logMAR best corrected visual acuity (BCVA), retinal nerve fiber layer (RNFL) thickness, spherical equivalent, intraocular pressure, axial length, central corneal thickness, white-to-white, and the kappa angle. Pupil size was significantly smaller in glaucoma patients than in glaucoma suspects (p < 0.001) or the normal group (p < 0.001). Pupil size decreased significantly as age (p < 0.001) and central cornea thickness (p = 0.007) increased, and increased significantly as logMAR BCVA (p = 0.02) became worse and spherical equivalent (p = 0.007) and RNFL thickness (p = 0.042) increased. In patients older than 50 years, pupil size was significantly larger in eyes with a history of cataract surgery. Humphrey static perimetry can be useful in measuring pupil size. Pupil size was significantly smaller in eyes with glaucoma. Other factors affecting pupil size can be used in a preoperative evaluation when considering cataract surgery or laser refractive surgery.

  11. The Relationship between Crystalline Lens Power and Refractive Error in Older Chinese Adults: The Shanghai Eye Study.

    PubMed

    He, Jiangnan; Lu, Lina; He, Xiangui; Xu, Xian; Du, Xuan; Zhang, Bo; Zhao, Huijuan; Sha, Jida; Zhu, Jianfeng; Zou, Haidong; Xu, Xun

    2017-01-01

    To report calculated crystalline lens power and describe the distribution of ocular biometry and its association with refractive error in older Chinese adults. Random clustering sampling was used to identify adults aged 50 years and above in Xuhui and Baoshan districts of Shanghai. Refraction was determined by subjective refraction that achieved the best corrected vision based on monocular measurement. Ocular biometry was measured by IOL Master. The crystalline lens power of right eyes was calculated using modified Bennett-Rabbetts formula. We analyzed 6099 normal phakic right eyes. The mean crystalline lens power was 20.34 ± 2.24D (range: 13.40-36.08). Lens power, spherical equivalent, and anterior chamber depth changed linearly with age; however, axial length, corneal power and AL/CR ratio did not vary with age. The overall prevalence of hyperopia, myopia, and high myopia was 48.48% (95% CI: 47.23%-49.74%), 22.82% (95% CI: 21.77%-23.88%), and 4.57% (95% CI: 4.05-5.10), respectively. The prevalence of hyperopia increased linearly with age while lens power decreased with age. In multivariate models, refractive error was strongly correlated with axial length, lens power, corneal power, and anterior chamber depth; refractive error was slightly correlated with best corrected visual acuity, age and sex. Lens power, hyperopia, and spherical equivalent changed linearly with age; Moreover, the continuous loss of lens power produced hyperopic shifts in refraction in subjects aged more than 50 years.

  12. Does endothelial cell density correlate with corneal diameter in a group of young adults?

    PubMed

    Giasson, Claude J; Gosselin, Lucie; Masella, Aviva; Forcier, Pierre

    2008-07-01

    In children, but not in the elderly, an association exists between corneal diameter and endothelial cell density (ECD). We tested whether such an association also held true in young adults. The eyes of 35 healthy subjects (mean age, 23.1 +/- 3.1 years) were photographed by using a video camera and a noncontact endothelial microscope. Both sets of images were analyzed with image software and the contour method to measure corneal diameter, ECD, and endothelial coefficients. Axial lengths, refractive errors, and corneal curvatures were measured by using an A-scan ultrasonic biometer and kerato-refractometer. Measurements, averaged for the right and left eyes, were analyzed depending on (1) use of contact lenses, (2) ametropia, and on whether (3) axial length or (4) corneal diameter was above or below group means. Differences were tested for statistical significance with independent t tests and association with the Pearson correlation coefficient. ECD, corneal diameter, and spherical equivalent refraction were 3022 +/- 262 cells/mm2, 12.0 +/- 0.5 mm, and -3.1 +/- 2.5 D, respectively. The only significant differences between wearers and nonwearers of contact lenses were the spherical refractive equivalent and axial length. There was no correlation between ECD and corneal diameter or axial length. As opposed to previously reported results in children, but as found in the elderly, there is no correlation between ECD and corneal diameter in young adults. Therefore, corneal size cannot be considered a determinant of ECD in young adults.

  13. Depth-dose equivalent relationship for cosmic rays at various solar minima

    NASA Technical Reports Server (NTRS)

    Badhwar, G. D.; Cucinotta, F. A.; O'Neill, P. M.

    1993-01-01

    Galactic cosmic rays (GCR) pose a serious radiation hazard for long-duration missions. In designing a lunar habitat or a Mars transfer vehicle, the radiation exposure determines the GCR shielding thickness, and hence the weight of spacecraft. Using the spherically symmetric diffusion theory of the solar modulation of GCR, and data on the differential energy spectra of H, He, O, and Fe, from 1965 to 1989, it has been shown that (1) the flux is determined by the diffusion parameter which is a function of the time in the solar cycle, and (2) the fluxes in the 1954 and 1976-1977 solar minima were similar and higher than those in 1965. In this paper, we have extended the spherical solar modulation theory back to 1954. The 1954-1955 GCR flux was nearly the same as that from 1976 to 1977; the 1965 flux values were nearly the same as those in 1986. Using this theory we have obtained the GCR spectra for all the nuclei, and calculated the depth dose as a function of Al thickness. It is shown that the shielding required to stay below 0.5 Sv is 17.5 -3/+8 g/sq cm of Al, and 9 -1.5/+5 g/sq cm to stay below 0.6 Sv. The calculated dose equivalent using the ICRP 60 values for quality factors is about 15 percent higher than that calculated using the ICRP 26 value.

  14. Scleral birefringence as measured by polarization-sensitive optical coherence tomography and ocular biometric parameters of human eyes in vivo.

    PubMed

    Yamanari, Masahiro; Nagase, Satoko; Fukuda, Shinichi; Ishii, Kotaro; Tanaka, Ryosuke; Yasui, Takeshi; Oshika, Tetsuro; Miura, Masahiro; Yasuno, Yoshiaki

    2014-05-01

    The relationship between scleral birefringence and biometric parameters of human eyes in vivo is investigated. Scleral birefringence near the limbus of 21 healthy human eyes was measured using polarization-sensitive optical coherence tomography. Spherical equivalent refractive error, axial eye length, and intraocular pressure (IOP) were measured in all subjects. IOP and scleral birefringence of human eyes in vivo was found to have statistically significant correlations (r = -0.63, P = 0.002). The slope of linear regression was -2.4 × 10(-2) deg/μm/mmHg. Neither spherical equivalent refractive error nor axial eye length had significant correlations with scleral birefringence. To evaluate the direct influence of IOP to scleral birefringence, scleral birefringence of 16 ex vivo porcine eyes was measured under controlled IOP of 5-60 mmHg. In these ex vivo porcine eyes, the mean linear regression slope between controlled IOP and scleral birefringence was -9.9 × 10(-4) deg/μm/mmHg. In addition, porcine scleral collagen fibers were observed with second-harmonic-generation (SHG) microscopy. SHG images of porcine sclera, measured on the external surface at the superior side to the cornea, showed highly aligned collagen fibers parallel to the limbus. In conclusion, scleral birefringence of healthy human eyes was correlated with IOP, indicating that the ultrastructure of scleral collagen was correlated with IOP. It remains to show whether scleral collagen ultrastructure of human eyes is affected by IOP as a long-term effect.

  15. The prevalence of refractive errors in 6- to 15-year-old schoolchildren in Dezful, Iran.

    PubMed

    Norouzirad, Reza; Hashemi, Hassan; Yekta, Abbasali; Nirouzad, Fereidon; Ostadimoghaddam, Hadi; Yazdani, Negareh; Dadbin, Nooshin; Javaherforoushzadeh, Ali; Khabazkhoob, Mehdi

    2015-01-01

    To determine the prevalence of refractive errors, among 6- to 15-year-old schoolchildren in the city of Dezful in western Iran. In this cross-sectional study, 1375 Dezful schoolchildren were selected through multistage cluster sampling. After obtaining written consent, participants had uncorrected and corrected visual acuity tests and cycloplegic refraction at the school site. Refractive errors were defined as myopia [spherical equivalent (SE) -0.5 diopter (D)], hyperopia (SE ≥ 2.0D), and astigmatism (cylinder error > 0.5D). 1151 (83.7%) schoolchildren participated in the study. Of these, 1130 completed their examinations. 21 individuals were excluded because of poor cooperation and contraindication for cycloplegic refraction. Prevalence of myopia, hyperopia, and astigmatism were 14.9% (95% confidence interval (CI): 10.1-19.6), 12.9% (95% CI: 7.2-18.6), and 45.3% (95% CI: 40.3-50.3), respectively. Multiple logistic regression analysis showed an age-related increase in myopia prevalence (p < 0.001) and a decrease in hyperopia prevalence (p < 0.001). There was a higher prevalence of myopia in boys (p<0.001) and hyperopia in girls (p = 0.007). This study showed a considerably high prevalence of refractive errors among the Iranian population of schoolchildren in Dezful in the west of Iran. The prevalence of myopia is considerably high compared to previous studies in Iran and increases with age.

  16. Solar system and equivalence principle constraints on f(R) gravity by the chameleon approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Capozziello, Salvatore; Tsujikawa, Shinji

    2008-05-15

    We study constraints on f(R) dark energy models from solar system experiments combined with experiments on the violation of the equivalence principle. When the mass of an equivalent scalar field degree of freedom is heavy in a region with high density, a spherically symmetric body has a thin shell so that an effective coupling of the fifth force is suppressed through a chameleon mechanism. We place experimental bounds on the cosmologically viable models recently proposed in the literature that have an asymptotic form f(R)=R-{lambda}R{sub c}[1-(R{sub c}/R){sup 2n}] in the regime R>>R{sub c}. From the solar system constraints on the post-Newtonianmore » parameter {gamma}, we derive the bound n>0.5, whereas the constraints from the violations of the weak and strong equivalence principles give the bound n>0.9. This allows a possibility to find the deviation from the {lambda}-cold dark matter ({lambda}CDM) cosmological model. For the model f(R)=R-{lambda}R{sub c}(R/R{sub c}){sup p} with 0

  17. Dynamic mechanism of equivalent conductivity minimum of electrolyte solution

    NASA Astrophysics Data System (ADS)

    Yamaguchi, T.; Matsuoka, T.; Koda, S.

    2011-10-01

    The theory on electric conductivity of electrolyte solutions we have developed [T. Yamaguchi, T. Matsuoka, and S. Koda, J. Chem. Phys. 127, 064508 (2007)] is applied to a model electrolyte solution that shows a minimum of equivalent conductivity as the function of concentration [T. Yamaguchi, T. Akatsuka, and S. Koda, J. Chem. Phys. 134, 244506 (2011)]. The theory succeeds in reproducing the equivalent conductivity minimum, whereas the mode-coupling theory (MCT) underestimates the conductivity in the low-concentration regime. The theory can also reproduce the decrease in the relaxation time of conductivity with increasing the concentration we have demonstrated with a Brownian dynamics simulation. A detailed analysis shows that the relaxation of the conductivity occurs through two processes. The faster one corresponds to the collision between a cation and an anion, and the slower one does to the polarization of the ionic atmosphere. The increase in the equivalent conductivity with concentration is attributed to the decrease in the effect of the ionic atmosphere, which is in turn explained by the fact that the counter ion cannot penetrate into the repulsive core when the Debye screening length is compatible or smaller than the ionic diameter. The same mechanism is also observed in MCT calculation with static structure factor determined by mean-spherical approximation.

  18. Design on the wide band absorber with low density based on the particle distribution

    NASA Astrophysics Data System (ADS)

    Zheng, Dianliang; Liu, Ting; Liu, Longbin; Xu, Yonggang

    2018-04-01

    In order to widen the absorbing band, an equivalent gradient structure absorber was designed based on the particle distribution. Firstly, the electromagnetic parameter of the absorbent with uniform dispersion was tested using the vector network analyzer in 8-18 GHz. Three different equivalent materials of the spherical, square and hexagon empty shape were designed. The scattering parameters and the monostatic reflection loss (RL) of the periodic structural materials were simulated in the commercial software. Then the effective permittivity and the permeability was derived by the Nicolson-Ross-Weir algorithm and fitted by Maxwell-Garnett mixing rule. The results showed that the simulated reflectance and transmission parameters of equivalent composites with the different shapes were very close. The derived effective permittivity and permeability of the composite with different absorbent content was also close, and the average deviation was about 0.52 + j0.15 and 0.15 + j0.01 respectively. Finally, the wide band absorbing material was designed using the genetic algorithm. The optimized RL result showed that the absorbing composites with thickness 3 mm had an excellent absorbing property (RL <-10 dB) in 8-18 GHz, the equivalent absorber density could be decreased 30.7% compared with the uniform structure.

  19. Comparison of photorefractive keratectomy and laser in situ keratomileusis for myopia of -6 D or less using the Nidek EC-5000 laser.

    PubMed

    Fernández, A P; Jaramillo, J; Jaramillo, M

    2000-01-01

    We compared the efficacy, predictability, and safety of photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) for the surgical correction of low and moderate myopia. A retrospective study was performed to evaluate uncorrected and spectacle-corrected visual acuity, and manifest refraction 1 year after PRK or LASIK. All procedures were done using an automatic microkeratome (Chiron Ophthalmic) and the Nidek EC-5000 excimer laser. PRK was performed in 75 eyes of 45 patients and LASIK in 133 eyes of 77 patients. Mean age for PRK patients was 32.8 years (range, 18 to 52 yr) and LASIK patients was 29.6 years (range, 18 to 49 yr). Mean preoperative spherical equivalent refraction for PRK patients was -3.28 D (range, -1.00 to -6.00 D) and LASIK, -3.86 D (range, -1.00 to -6.00 D). One year after surgery, mean spherical equivalent refraction for Group 1 (baseline, -1.00 to -3.00 D) PRK eyes was -0.18 +/- 0.61 D (range, -1.50 to +0.75 D) and for LASIK eyes, -0.08 +/- 0.61 D (range, -1.50 to +1.62 D), with no statistically significant difference. For Group 2 eyes (baseline, -3.25 to -6.00 D), mean spherical equivalent refraction for PRK eyes was -0.44 +/- 0.87 D (range, -2.00 to +2.12 D) and for LASIK eyes, -0.09 +/- 0.83 D (range, -1.50 to +1.75 D), with no statistically significant difference. The antilogarithm of the mean UCVA (antilogUCVA) in Group 1 for PRK was 0.79 +/- 0.21 (20/25) and for LASIK was 0.87 +/- 0.19 (20/23), with no statistically significant difference. The antilogUCVA in Group 2 for PRK eyes was 0.70 +/- 0.24 (20/28) and for LASIK eyes was 0.83 +/- 0.18 (20/24), with a statistically significant difference (0.7 vs. 0.83, P < .005). The percentage of eyes with a postoperative UCVA >20/40 in Group 1 for PRK was 91.5% (38 eyes) and for LASIK was 95% (50 eyes) (no statistically significant difference), and in Group 2 for PRK eyes, it was 82% (27 eyes) and 97.5% (78 eyes) for LASIK (statistically significant difference, P < .05). PRK and LASIK with the Nidek EC-5000 excimer laser are effective and safe for correcting low to moderate myopia, but LASIK eyes showed better results for moderate myopia in terms of uncorrected visual acuity.

  20. Population-based assessment of sensitivity and specificity of a pinhole for detection of significant refractive errors in the community.

    PubMed

    Marmamula, Srinivas; Keeffe, Jill E; Narsaiah, Saggam; Khanna, Rohit C; Rao, Gullapalli N

    2014-11-01

    Measurements of refractive errors through subjective or automated refraction are not always possible in rapid assessment studies and community vision screening programs; however, measurements of vision with habitual correction and with a pinhole can easily be made. Although improvements in vision with a pinhole are assumed to mean that a refractive error is present, no studies have investigated the magnitude of improvement in vision with pinhole that is predictive of refractive error. The aim was to measure the sensitivity and specificity of 'vision improvement with pinhole' in predicting the presence of refractive error in a community setting. Vision and vision with pinhole were measured using a logMAR chart for 488 of 582 individuals aged 15 to 50 years. Refractive errors were measured using non-cycloplegic autorefraction and subjective refraction. The presence of refractive error was defined using spherical equivalent refraction (SER) at two levels: SER greater than ± 0.50 D sphere (DS) and SER greater than ±1.00 DS. Three definitions for significant improvement in vision with a pinhole were used: 1. Presenting vision less than 6/12 and improving to 6/12 or better, 2. Improvement in vision of more than one logMAR line and 3. Improvement in vision of more than two logMAR lines. For refractive error defined as spherical equivalent refraction greater than ± 0.50 DS, the sensitivities and specificities for the pinhole test predicting the presence of refractive error were 83.9 per cent (95% CI: 74.5 to 90.9) and 98.8 per cent (95% CI: 97.1 to 99.6), respectively for definition 1. Definition 2 had a sensitivity 89.7 per cent (95% CI: 81.3 to 95.2) and specificity 88.0 per cent (95% CI: 4.4 to 91.0). Definition 3 had a sensitivity of 75.9 per cent (95% CI: 65.5 to 84.4) and specificity of 97.8 per cent (95% CI: 95.8 to 99.0). Similar results were found with spherical equivalent refraction greater than ±1.00 DS, when tested against the three pinhole-based definitions. Refractive error definitions based on improvement in vision with the pinhole shows good sensitivity and specificity at predicting the presence of significant refractive errors. These definitions can be used in rapid assessment surveys and community-based vision screenings. © 2014 The Authors. Clinical and Experimental Optometry © 2014 Optometrists Association Australia.

  1. Refractive errors in students from Middle Eastern backgrounds living and undertaking schooling in Australia.

    PubMed

    Azizoglu, Serap; Junghans, Barbara M; Barutchu, Ayla; Crewther, Sheila G

    2011-01-01

      Environmental factors associated with schooling systems in various countries have been implicated in the rising prevalence of myopia, making the comparison of prevalence of refractive errors in migrant populations of interest. This study aims to determine the prevalence of refractive errors in children of Middle Eastern descent, raised and living in urban Australia but actively maintaining strong ties to their ethnic culture, and to compare them with those in the Middle East where myopia prevalence is generally low.   A total of 354 out of a possible 384 late primary/early secondary schoolchildren attending a private school attracting children of Middle Eastern background in Melbourne were assessed for refractive error and visual acuity. A Shin Nippon open-field NVision-K5001 autorefractor was used to carry out non-cycloplegic autorefraction while viewing a distant target. For statistical analyses students were divided into three age groups: 10-11 years (n = 93); 12-13 years (n = 158); and 14-15 years (n = 102).   All children were bilingual and classified as of Middle Eastern (96.3 per cent) or Egyptian (3.7 per cent) origin. Ages ranged from 10 to 15 years, with a mean of 13.17 ± 0.8 (SEM) years. Mean spherical equivalent refraction (SER) for the right eye was +0.09 ± 0.07 D (SEM) with a range from -7.77 D to +5.85 D. The prevalence of myopia, defined as a spherical equivalent refraction 0.50 D or more of myopia, was 14.7 per cent. The prevalence of hyperopia, defined as a spherical equivalent refraction of +0.75 D or greater, was 16.4 per cent, while hyperopia of +1.50 D or greater was 5.4 per cent. A significant difference in SER was seen as a function of age; however, no significant gender difference was seen.   This is the first study to report the prevalence of refractive errors for second-generation Australian schoolchildren coming from a predominantly Lebanese Middle Eastern Arabic background, who endeavour to maintain their ethnic ties. The relatively low prevalence of myopia is similar to that found for other metropolitan Australian school children but higher than that reported in the Middle East. These results suggest that lifestyle and educational practices may be a significant influence in the progression of myopic refractive errors. © 2010 The Authors. Clinical and Experimental Optometry © 2010 Optometrists Association Australia.

  2. Comparison of localized retinal nerve fiber layer defects between a low-teen intraocular pressure group and a high-teen intraocular pressure group in normal-tension glaucoma patients.

    PubMed

    Kim, Dong Myung; Seo, Je Hyun; Kim, Seok Hwan; Hwang, Seung-Sik

    2007-05-01

    To compare the features of localized retinal nerve fiber layer (RNFL) defects between a low-teen intraocular pressure (IOP) group and a high-teen IOP group in normal-tension glaucoma (NTG) patients. Seventy-seven eyes of 77 NTG patients showing localized RNFL defects on RNFL photographs and corresponding visual filed defects at the initial visit to a glaucoma specialist were selected for this study. Patients with range of diurnal IOP within low-teen or high-teen in both eyes were included. All participants completed refraction, diurnal IOP measurement, central corneal thickness (CCT) measurement, stereoscopic disc photography, RNFL photography, and automated perimetry. On RNFL photograph, approximation of the defect to the macula (angle alpha) and width of the defects (angle beta) were measured to represent RNFL defects. The patients were divided into 2 groups according to the level of IOP. A low-teen group had highest IOP of 15 mm Hg (group B). Age at diagnosis, percentage of male patients, systemic disease, refraction, CCT, highest IOP, angle alpha, angle beta, and mean deviation and pattern standard deviation of visual field were compared between the 2 groups. Age at diagnosis of NTG, age distribution, percentage of male patients, systemic disease, spherical equivalent of refraction, CCT, mean deviation, and pattern standard deviation were not different between the 2 groups. Highest IOP was 13.8+/-1.2 mm Hg in group A and 19.2+/-1.4 mm Hg in group B (P<0.001). Angle alpha was significantly smaller in group A than in group B (37.0+/-14.0 vs. 56.5+/-21.2 degrees, P<0.001), whereas angle beta was not different between the 2 groups (39.9+/-17.9 vs. 37.5+/-15.9 degrees, P=0.54). There were no significant correlations between spherical equivalent and angle alpha (r=-0.03, P=0.82), between spherical equivalent and angle beta (r=-0.04, P=0.74), and between angle alpha and angle beta (r=-0.21, P=0.07). Localized RNFL defect was closer to the center of the macula in group A than in group B, whereas width of defects was not different between the 2 groups. These findings provide indirect evidence to suggest that more than one pathogenic mechanism may exist in the development of RNFL defects in NTG.

  3. Biomimetic Synthesis of Selenium Nanospheres by Bacterial Strain JS-11 and Its Role as a Biosensor for Nanotoxicity Assessment: A Novel Se-Bioassay

    PubMed Central

    Dwivedi, Sourabh; AlKhedhairy, Abdulaziz A.; Ahamed, Maqusood; Musarrat, Javed

    2013-01-01

    Selenium nanoparticles (Se-NPs) were synthesized by green technology using the bacterial isolate Pseudomonas aeruginosa strain JS-11. The bacteria exhibited significant tolerance to selenite (SeO3 2−) up to 100 mM concentration with an EC50 value of 140 mM. The spent medium (culture supernatant) contains the potential of reducing soluble and colorless SeO3 2− to insoluble red elemental selenium (Se0) at 37°C. Characterization of red Se° product by use of UV-Vis spectroscopy, X-ray diffraction (XRD), atomic force microscopy (AFM) and transmission electron microscopy (TEM) with energy dispersive X-ray spectrum (EDX) analysis revealed the presence of stable, predominantly monodispersed and spherical selenium nanoparticles (Se-NPs) of an average size of 21 nm. Most likely, the metabolite phenazine-1-carboxylic acid (PCA) released by strain JS-11 in culture supernatant along with the known redox agents like NADH and NADH dependent reductases are responsible for biomimetic reduction of SeO3 2− to Se° nanospheres. Based on the bioreduction of a colorless solution of SeO3 2− to elemental red Se0, a high throughput colorimetric bioassay (Se-Assay) was developed for parallel detection and quantification of nanoparticles (NPs) cytotoxicity in a 96 well format. Thus, it has been concluded that the reducing power of the culture supernatant of strain JS-11 could be effectively exploited for developing a simple and environmental friendly method of Se-NPs synthesis. The results elucidated that the red colored Se° nanospheres may serve as a biosensor for nanotoxicity assessment, contemplating the inhibition of SeO3 2− bioreduction process in NPs treated bacterial cell culture supernatant, as a toxicity end point. PMID:23483909

  4. Prevalence and risk factors for visual impairment in preschool children the sydney paediatric eye disease study.

    PubMed

    Pai, Amy Shih-I; Wang, Jie Jin; Samarawickrama, Chameen; Burlutsky, George; Rose, Kathryn A; Varma, Rohit; Wong, Tien Yin; Mitchell, Paul

    2011-08-01

    To assess the prevalence and associations of visual impairment (VI) in preschool children. Cross-sectional, population-based study. A total of 2461 children (73.8% participation rate), aged 6 to 72 months, were examined in the Sydney Paediatric Eye Disease Study during 2007-2009; of whom 1188, aged 30 to 72 months, with complete visual acuity (VA) data in both eyes, were included in this report. Measurement of VA was attempted on all children using the Electronic Visual Acuity (EVA) system or a logarithm of the minimum angle of resolution (logMAR) chart. Visual impairment was defined as presenting VA <20/40 in children aged ≥48 months and <20/50 in those aged <48 months. Post-cycloplegic refraction was measured, and myopia was defined as spherical equivalent (SE) ≤-0.50 diopters (D), hyperopia was defined as SE ≥2.00 D, astigmatism was defined as cylinder ≥1.00 D, and anisometropia was defined as SE difference ≥1.00 D between 2 eyes. Ethnicity, birth parameters, and sociodemographic information were collected in questionnaires completed by parents. Visual impairment prevalence and its associations with child demographic factors and birth parameters. Visual impairment was found in 6.4% of the worse eye and 2.7% of the better eye in our sample. Refractive errors (69.7%) and amblyopia (26.3%) were the principal causes of VI in the worse eye. Astigmatism (51.3%) and hyperopia (28.9%) were the main refractive errors causing VI. In regression analysis controlling for other factors, VI was independently associated with low birthweight of <2500 g (odds ratio 2.4, 95% confidence interval, 1.1-5.3), but not with age, gender, ethnicity, or measures of socioeconomic status (P > 0.05). Visual impairment in at least 1 eye was found in 6.4% of Australian preschool children, with bilateral VI found in 2.7%. Uncorrected refractive errors and amblyopia were the principal ocular conditions associated with VI. Low birthweight was a significant risk factor independent of age, gender, and ethnicity. The author(s) have no proprietary or commercial interest in any materials discussed in this article. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  5. Posterior corneal curvature changes following Refractive Small Incision Lenticule Extraction

    PubMed Central

    Ganesh, Sri; Patel, Utsav; Brar, Sheetal

    2015-01-01

    Purpose To compare the posterior corneal curvature changes, in terms of corneal power and asphercity, following Refractive Small Incision Lenticule Extraction (ReLEx SMILE) procedure for low, moderate, and high myopia. Methods This retrospective, non randomized, comparative, interventional trial; included 52 eyes of 26 patients, divided in three groups: low myopia (myopia ≤3 D [diopters] spherical equivalent [SE]), moderate myopia (myopia >3 D and <6 D SE), and high myopia (myopia ≥6 D SE). All patients were treated for myopia and myopic astigmatism using ReLEx SMILE. The eyes were examined pre-operatively and 3 months post-operatively using SCHWIND SIRIUS, a three-dimensional rotating Scheimpflug camera with a Placido disc topographer to assess corneal changes with regard to keratometric power and asphericity of the cornea. Results A statistically significant increase in mean keratometric power in the 3, 5, and 7 mm zones of the posterior corneal surface compared with its pre-ReLEx SMILE value was detected after 3 months in the moderate myopia group (pre-operative [pre-op] −6.14±0.23, post-operative [post-op] −6.29±0.22, P<0.001) and high myopia group (pre-op −6.19±0.16, post-op −6.4±0.18, P<0.001), but there was no significant change in keratometric power of the posterior surface in the low myopia group (pre-op −5.87±0.17, post-op −6.06±0.29, P=0.143). Asphericity (Q-value) of the posterior surface changed significantly (P<0.001) after ReLEx SMILE in the moderate myopia group in the 3, 5, and 7 mm zones, and in the high myopia group in the 3 and 7 mm zones; but there was no significant change in the Q-value in the low myopia group in all three zones (pre-op 0.23±0.43, post-op −0.40±0.71, P=0.170), and in the high myopia group in the 5 mm zone (P=0.228). Conclusion ReLEx SMILE causes significant changes in posterior corneal keratometric power and asphericity in moderate and high myopia, but the effect is subtle and insignificant in low myopia. PMID:26229428

  6. Geopotential Field Anomaly Continuation with Multi-Altitude Observations

    NASA Technical Reports Server (NTRS)

    Kim, Jeong Woo; Kim, Hyung Rae; von Frese, Ralph; Taylor, Patrick; Rangelova, Elena

    2012-01-01

    Conventional gravity and magnetic anomaly continuation invokes the standard Poisson boundary condition of a zero anomaly at an infinite vertical distance from the observation surface. This simple continuation is limited, however, where multiple altitude slices of the anomaly field have been observed. Increasingly, areas are becoming available constrained by multiple boundary conditions from surface, airborne, and satellite surveys. This paper describes the implementation of continuation with multi-altitude boundary conditions in Cartesian and spherical coordinates and investigates the advantages and limitations of these applications. Continuations by EPS (Equivalent Point Source) inversion and the FT (Fourier Transform), as well as by SCHA (Spherical Cap Harmonic Analysis) are considered. These methods were selected because they are especially well suited for analyzing multi-altitude data over finite patches of the earth such as covered by the ADMAP database. In general, continuations constrained by multi-altitude data surfaces are invariably superior to those constrained by a single altitude data surface due to anomaly measurement errors and the non-uniqueness of continuation.

  7. Geopotential Field Anomaly Continuation with Multi-Altitude Observations

    NASA Technical Reports Server (NTRS)

    Kim, Jeong Woo; Kim, Hyung Rae; vonFrese, Ralph; Taylor, Patrick; Rangelova, Elena

    2011-01-01

    Conventional gravity and magnetic anomaly continuation invokes the standard Poisson boundary condition of a zero anomaly at an infinite vertical distance from the observation surface. This simple continuation is limited, however, where multiple altitude slices of the anomaly field have been observed. Increasingly, areas are becoming available constrained by multiple boundary conditions from surface, airborne, and satellite surveys. This paper describes the implementation of continuation with multi-altitude boundary conditions in Cartesian and spherical coordinates and investigates the advantages and limitations of these applications. Continuations by EPS (Equivalent Point Source) inversion and the FT (Fourier Transform), as well as by SCHA (Spherical Cap Harmonic Analysis) are considered. These methods were selected because they are especially well suited for analyzing multi-altitude data over finite patches of the earth such as covered by the ADMAP database. In general, continuations constrained by multi-altitude data surfaces are invariably superior to those constrained by a single altitude data surface due to anomaly measurement errors and the non-uniqueness of continuation.

  8. Comment on the Exterior Solutions and Their Geometry in Scalar-Tensor Theories of Gravity

    NASA Astrophysics Data System (ADS)

    Tsuchida, T.; Watanabe, K.

    1999-01-01

    We study series of stationary solutions with asymptotic flatness properties in the Einstein-Maxwell-free scalar system because they are locally equivalent to the exterior solutions in some class of scalar-tensor theories of gravity. First, we classify spherical exterior solutions into two types of solutions, an apparently black hole type solution and an apparently worm hole type solution. The solutions contain three parameters, and we clarify their physical significance. Second, we reduce the field equations for the axisymmetric exterior solutions. We find that the reduced equations are partially the same as the Ernst equations. As simple examples, we derive new series of static, axisymmetric exterior solutions, which correspond to Voorhees's solutions. We then establish a non-trivial relation between the spherical exterior solutions and our new solutions. Finally, since null geodesics have conformally invariant properties, we study the local geometry of the exterior solutions by using the optical scalar equations and find some anomalous behavior of the null geodesics.

  9. Mixed Lubrication Simulation of Hydrostatic Spherical Bearings for Hydraulic Piston Pumps and Motors

    NASA Astrophysics Data System (ADS)

    Kazama, Toshiharu

    Mixed and fluid film lubrication characteristics of hydrostatic spherical bearings for swash-plate-type axial piston pumps and motors are studied theoretically under non-steady-state conditions. The basic equations incorporating interference and contact of surface roughness are derived fundamentally through combination of the GW and PC models. Furthermore, a programming code that is applicable to the caulked-socket-type and open-socket-type bearings is developed. Effects of caulking, operating conditions, and the bearing dimension on the motion of the sphere and tribological performance of the bearings are examined. Salient conclusions are the following: The sphere's eccentricity increases in the low supply pressure period. The time-lag of the load change engenders greater motion of the sphere. Caulking of the bearing socket suppresses the sphere's motion. The bearing stiffness increases and power loss decreases for smaller recess angles. Minimum power loss is given under the condition that the bearing socket radius nearly equals the equivalent load radius.

  10. FAST TRACK COMMUNICATION: Gas liquid phase coexistence in a tetrahedral patchy particle model

    NASA Astrophysics Data System (ADS)

    Romano, Flavio; Tartaglia, Piero; Sciortino, Francesco

    2007-08-01

    We evaluate the location of the gas-liquid coexistence line and of the associated critical point for the primitive model for water (PMW), introduced by Kolafa and Nezbeda (1987 Mol. Phys. 61 161). Besides being a simple model for a molecular network forming liquid, the PMW is representative of patchy proteins and novel colloidal particles interacting with localized directional short-range attractions. We show that the gas-liquid phase separation is metastable, i.e. it takes place in the region of the phase diagram where the crystal phase is thermodynamically favoured, as in the case of particles interacting via short-range attractive spherical potentials. We do not observe crystallization close to the critical point. The region of gas-liquid instability of this patchy model is significantly reduced as compared to that from equivalent models of spherically interacting particles, confirming the possibility of observing kinetic arrest in a homogeneous sample driven by bonding as opposed to packing.

  11. Shock waves from non-spherically collapsing cavitation bubbles

    NASA Astrophysics Data System (ADS)

    Supponen, Outi; Obreschkow, Danail; Farhat, Mohamed

    2017-11-01

    Combining simultaneous high-speed imaging and hydrophone measurements, we uncover details of the multiple shock wave emission from laser-induced cavitation bubbles collapsing in a non-spherical way. For strongly deformed bubbles collapsing near a free surface, we identify the distinct shock waves caused by the jet impact onto the opposite bubble wall and by the individual collapses of the remaining bubble segments. The energy carried by each of these shocks depends on the level of bubble deformation, quantified by the anisotropy parameter ζ, the dimensionless equivalent of the Kelvin impulse. For jetting bubbles, at ζ < 0.01 , the jet impact hammer pressure is found to be the most energetic shock. Through statistical analysis of the experimental data and theoretical derivations, and by comparing bubbles deformed by different sources (variable gravity achieved on parabolic flights, and neighboring free and rigid surfaces), we find that the shock peak pressure may be approximated as the jet impact-induced water hammer as ph = 0.45 (ρc2 Δp) 1 / 2ζ-1 .

  12. Determination of size and mass-and number-based concentration of biogenic SeNPs synthesized by lactic acid bacteria by using a multimethod approach.

    PubMed

    Moreno-Martin, Gustavo; Pescuma, Micaela; Pérez-Corona, Teresa; Mozzi, Fernanda; Madrid, Yolanda

    2017-11-01

    Selenium nanoparticles (SeNPs) were synthesized by a green technology using lactic acid bacteria (LAB, Lactobacillus acidophilus, L. delbrueckii subsp. bulgaricus and L. reuteri). The exposure of aqueous sodium selenite to LAB led to the synthesis of SeNPs. Characterization of SeNPs by transmission electron microscopy with energy dispersive X-ray spectrum (EDXS) analysis revealed the presence of stable, predominantly monodispersed and spherical SeNPs of an average size of 146 ± 71 nm. Additionally, SeNPs hydrodynamic size was determined by dispersive light scattering (DLS) and nanoparticle tracking analysis (NTA). For this purpose, a methodology based on the use of surfactants in basic medium was developed for isolating SeNPs from the bacterial pellet. The hydrodynamic size values provided by DLS and NTA were 258 ± 4 and 187 ± 56 nm, respectively. NTA measurements of number-based concentration reported values of (4.67±0.30)x10 9 SeNPs mL -1 with a relative standard deviation lower than 5% (n = 3). The quantitative results obtained by NTA were supported by theoretical calculations. Asymmetrical flow field flow fractionation (AF 4 ) on line coupled to the inductively couple plasma mass spectrometry (ICP-MS) and off-line coupled to DLS was further employed to characterize biogenic SeNPs. The distribution of the particle size for the Se-containing peak provide an average size of (247 ± 14) nm. The data obtained by independent techniques were in good agreement and the developed methodology could be implemented for characterizing NPs in complex matrices such as biogenic nanoparticles embedded inside microbial material. Copyright © 2017. Published by Elsevier B.V.

  13. Strain-Driven Stacking Faults in CdSe/CdS Core/Shell Nanorods.

    PubMed

    Demortière, Arnaud; Leonard, Donovan N; Petkov, Valeri; Chapman, Karena; Chattopadhyay, Soma; She, Chunxing; Cullen, David A; Shibata, Tomohiro; Pelton, Matthew; Shevchenko, Elena V

    2018-04-19

    Colloidal semiconductor nanocrystals are commonly grown with a shell of a second semiconductor material to obtain desired physical properties, such as increased photoluminescence quantum yield. However, the growth of a lattice-mismatched shell results in strain within the nanocrystal, and this strain has the potential to produce crystalline defects. Here, we study CdSe/CdS core/shell nanorods as a model system to investigate the influence of core size and shape on the formation of stacking faults in the nanocrystal. Using a combination of high-angle annular dark-field scanning transmission electron microscopy and pair-distribution-function analysis of synchrotron X-ray scattering, we show that growth of the CdS shell on smaller, spherical CdSe cores results in relatively small strain and few stacking faults. By contrast, growth of the shell on larger, prolate spheroidal cores leads to significant strain in the CdS lattice, resulting in a high density of stacking faults.

  14. Simulating the blast wave from detonation of a charge using a balloon of compressed air

    NASA Astrophysics Data System (ADS)

    Blanc, L.; Santana Herrera, S.; Hanus, J. L.

    2018-07-01

    This paper investigates a simple numerical method, based on the release of a pressurized spherical air volume, to predict or reproduce the main characteristics of the blast environment from the detonation of solid or gaseous charges. This approach aims to give an alternative to the use of a steady-state detonation model and a Jones-Wilkins-Lee equation of state to describe the expansion of the detonation products, especially when the explosive parameters are unknown and a TNT equivalent is used. The validity of the proposed approach is assessed through the comparison of predicted overpressure and impulse at different distances from the explosion with that of TNT and stoichiometric propane-oxygen explosions. It is also shown that, for gaseous detonations, a better agreement is obtained with the rationally optimized compressed balloon than with the use of a Jones-Wilkins-Lee model and a TNT equivalent mass.

  15. Simulating the blast wave from detonation of a charge using a balloon of compressed air

    NASA Astrophysics Data System (ADS)

    Blanc, L.; Santana Herrera, S.; Hanus, J. L.

    2017-11-01

    This paper investigates a simple numerical method, based on the release of a pressurized spherical air volume, to predict or reproduce the main characteristics of the blast environment from the detonation of solid or gaseous charges. This approach aims to give an alternative to the use of a steady-state detonation model and a Jones-Wilkins-Lee equation of state to describe the expansion of the detonation products, especially when the explosive parameters are unknown and a TNT equivalent is used. The validity of the proposed approach is assessed through the comparison of predicted overpressure and impulse at different distances from the explosion with that of TNT and stoichiometric propane-oxygen explosions. It is also shown that, for gaseous detonations, a better agreement is obtained with the rationally optimized compressed balloon than with the use of a Jones-Wilkins-Lee model and a TNT equivalent mass.

  16. Validation of Slosh Model Parameters and Anti-Slosh Baffle Designs of Propellant Tanks by Using Lateral Slosh Testing

    NASA Technical Reports Server (NTRS)

    Perez, Jose G.; Parks, Russel A.; Lazor, Daniel R.

    2012-01-01

    The slosh dynamics of propellant tanks can be represented by an equivalent pendulum-mass mechanical model. The parameters of this equivalent model, identified as slosh model parameters, are slosh mass, slosh mass center of gravity, slosh frequency, and smooth-wall damping. They can be obtained by both analysis and testing for discrete fill heights. Anti-slosh baffles are usually needed in propellant tanks to control the movement of the fluid inside the tank. Lateral slosh testing, involving both random testing and free-decay testing, are performed to validate the slosh model parameters and the damping added to the fluid by the anti-slosh baffles. Traditional modal analysis procedures are used to extract the parameters from the experimental data. Test setup of sub-scale test articles of cylindrical and spherical shapes will be described. A comparison between experimental results and analysis will be presented.

  17. A new class of sonic composites

    NASA Astrophysics Data System (ADS)

    Munteanu, Ligia; Chiroiu, Veturia; Donescu, Ştefania; Brişan, Cornel

    2014-03-01

    Transformation acoustics opens a new avenue towards the architecture, modeling and simulation of a new class of sonic composites with scatterers made of various materials and having various shapes embedded in an epoxy matrix. The design of acoustic scatterers is based on the property of Helmholtz equations to be invariant under a coordinate transformation, i.e., a specific spatial compression is equivalent to a new material in a new space. In this paper, the noise suppression for a wide full band-gap of frequencies is discussed for spherical shell scatterers made of auxetic materials (materials with negative Poisson's ratio). The original domain consists of spheres made from conventional foams with positive Poisson's ratio. The spatial compression is controlled by the coordinate transformation, and leads to an equivalent domain filled with an auxetic material. The coordinate transformation is strongly supported by the manufacturing of auxetics which is based on the pore size reduction through radial compression molds.

  18. Measured neutron and gamma spectra from californium-252 in a tissue-equivalent medium.

    PubMed

    Elson, H R; Stupar, T A; Shapiro, A; Kereiakes, J G

    1979-01-01

    A method of experimentally obtaining both neutron and gamma-ray spectra in a scattering medium is described. The method utilizes a liquid-organic scintillator (NE-213) coupled with a pulse-shape discrimination circuit. This allows the separation of the neutron-induced pulse-height data from the gamma-ray pulse-height data. Using mathematical unfolding techniques, the two sets of pulse-height data were transformed to obtain the neutron and gamma-ray energy spectra. A small spherical detector was designed and constructed to reduce the errors incurred by attempting spectral measurements in a scattering medium. Demonstration of the utility of the system to obtain the neutron and gamma-ray spectra in a scattering medium was performed by characterizing the neutron and gamma-ray spectra at various sites about a 3.7-microgram (1.5 cm active length) californium-252 source in a tissue-equivalent medium.

  19. Imploding spherical and cylindrical shocks

    NASA Astrophysics Data System (ADS)

    Yousaf, M.

    1986-03-01

    In this paper it is shown that the value of the similarity exponent α derived analytically by Fujimoto and Mishkin [J. Fluid Mech. 89, 61 (1978); Phys. Fluids 21, 1933 (1978)] is exactly the same as that found by Stanyukovich [Unsteady Motion of Continuous Media, (Academic, New York, 1960)]. Since the result found by Stanyukovich is an approximation to α, Fujimoto and Mishkin's claim to have an exact expression of α is false. The two methods are outlined and Stanyukovich's result is simplified to show its equivalence to the work of Fujimoto and Mishkin.

  20. Coherent electromagnetic waves in the presence of a half space of randomly distributed scatterers

    NASA Technical Reports Server (NTRS)

    Karam, M. A.; Fung, A. K.

    1988-01-01

    The present investigation of coherent field propagation notes, upon solving the Foldy-Twersky integral equation for a half-space of small spherical scatterers illuminated by a plane wave at oblique incidence, that the coherent field for a horizontally-polarized incident wave exhibits reflectivity and transmissivity consistent with the Fresnel formula for an equivalent continuous effective medium. In the case of a vertically polarized incident wave, both the vertical and longitudinal waves obtained for the coherent field have reflectivities and transmissivities that do not agree with the Fresnel formula.

  1. Condition Survey of Lock Number 2, Monongahela River

    DTIC Science & Technology

    1988-08-01

    locks structure. The condition survey of the much older dam was not part of this effort. The dam is submerged at all times and did not lend itself to a...TAmEN MBR WES L-2-86 I& TOTAL PUMER come BoxesL MARC OF ORILLEi’ Gene Warhurst IS. L.[LVATION GROUNo WATEN N. DIRECTION OP ,OLE Feb 86 "OLE Feb 86 SES...Equivalent Spherical Diameter ** See References at the end of the main text. D3 It remained intact when submerged in water. The rock had some iron

  2. Convergence of quantum electrodynamics in a curved modification of Minkowski space.

    PubMed Central

    Segal, I E; Zhou, Z

    1994-01-01

    The interaction and total hamiltonians for quantum electrodynamics, in the interaction representation, are entirely regular self-adjoint operators in Hilbert space, in the universal covering manifold M of the conformal compactification of Minkowski space Mo. (M is conformally equivalent to the Einstein universe E, in which Mo may be canonically imbedded.) In a fixed Lorentz frame this may be expressed as convergence in a spherical space with suitable periodic boundary conditions in time. The traditional relativistic theory is the formal limit of the present variant as the space curvature vanishes. PMID:11607455

  3. Rumen Microorganisms Decrease Bioavailability of Inorganic Selenium Supplements.

    PubMed

    Galbraith, M L; Vorachek, W R; Estill, C T; Whanger, P D; Bobe, G; Davis, T Z; Hall, J A

    2016-06-01

    Despite the availability of selenium (Se)-enriched trace mineral supplements, we have observed low Se status in cattle and sheep offered traditional inorganic Se supplements. Reasons for this may include inadequate intake or low bioavailability of inorganic Se sources. The objective of this study was to determine whether rumen microorganisms (RMO) alter the bioavailability of Se sources commonly used in Se supplements. Rumen microorganisms were isolated from ewes (n = 4) and incubated ex vivo with no Se (control), with inorganic Na selenite or Na selenate, or with organic selenomethionine (SeMet). Total Se incorporated into RMO and the amount of elemental Se formed were determined under equivalent conditions. Incorporation of Se from Na selenite, Na selenate, or SeMet into RMO was measured as fold change compared with control (no added Se). Incorporation of Se into microbial mass was greater for SeMet (13.2-fold greater than no-Se control) compared with inorganic Se supplements (P = 0.02); no differences were observed between inorganic Na selenate (3.3-fold greater than no-Se control) and Na selenite (3.5-fold greater than no-Se control; P = 0.97). Formation of non-bioavailable, elemental Se was less for RMO incubated with SeMet compared with inorganic Se sources (P = 0.01); no differences were observed between Na selenate and Na selenite (P = 0.09). The clinical importance of these results is that the oral bioavailability of organic SeMet should be greater compared with inorganic Se sources because of greater RMO incorporation of Se and decreased formation of elemental Se by RMO.

  4. Contribution of the gradient refractive index and shape to the crystalline lens spherical aberration and astigmatism.

    PubMed

    Birkenfeld, Judith; de Castro, Alberto; Ortiz, Sergio; Pascual, Daniel; Marcos, Susana

    2013-06-28

    The optical properties of the crystalline lens are determined by its shape and refractive index distribution. However, to date, those properties have not been measured together in the same lens, and therefore their relative contributions to optical aberrations are not fully understood. The shape, the optical path difference, and the focal length of ten porcine lenses (age around 6 months) were measured in vitro using Optical Coherence Tomography and laser ray tracing. The 3D Gradient Refractive Index distribution (GRIN) was reconstructed by means of an optimization method based on genetic algorithms. The optimization method searched for the parameters of a 4-variable GRIN model that best fits the distorted posterior surface of the lens in 18 different meridians. Spherical aberration and astigmatism of the lenses were estimated using computational ray tracing, with the reconstructed GRIN lens and an equivalent homogeneous refractive index. For all lenses the posterior radius of curvature was systematically steeper than the anterior one, and the conic constant of both the anterior and posterior positive surfaces was positive. In average, the measured focal length increased with increasing pupil diameter, consistent with a crystalline lens negative spherical aberration. The refractive index of nucleus and surface was reconstructed to an average value of 1.427 and 1.364, respectively, for 633 nm. The results of the GRIN reconstruction showed a wide distribution of the index in all lens samples. The GRIN shifted spherical aberration towards negative values when compared to a homogeneous index. A negative spherical aberration with GRIN was found in 8 of the 10 lenses. The presence of GRIN also produced a decrease in the total amount of lens astigmatism in most lenses, while the axis of astigmatism was only little influenced by the presence of GRIN. To our knowledge, this study is the first systematic experimental study of the relative contribution of geometry and GRIN to the aberrations in a mammal lens. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Renormalizable Quantum Field Theories in the Large -n Limit

    NASA Astrophysics Data System (ADS)

    Guruswamy, Sathya

    1995-01-01

    In this thesis, we study two examples of renormalizable quantum field theories in the large-N limit. Chapter one is a general introduction describing physical motivations for studying such theories. In chapter two, we describe the large-N method in field theory and discuss the pioneering work of 't Hooft in large-N two-dimensional Quantum Chromodynamics (QCD). In chapter three we study a spherically symmetric approximation to four-dimensional QCD ('spherical QCD'). We recast spherical QCD into a bilocal (constrained) theory of hadrons which in the large-N limit is equivalent to large-N spherical QCD for all energy scales. The linear approximation to this theory gives an eigenvalue equation which is the analogue of the well-known 't Hooft's integral equation in two dimensions. This eigenvalue equation is a scale invariant one and therefore leads to divergences in the theory. We give a non-perturbative renormalization prescription to cure this and obtain a beta function which shows that large-N spherical QCD is asymptotically free. In chapter four, we review the essentials of conformal field theories in two and higher dimensions, particularly in the context of critical phenomena. In chapter five, we study the O(N) non-linear sigma model on three-dimensional curved spaces in the large-N limit and show that there is a non-trivial ultraviolet stable critical point at which it becomes conformally invariant. We study this model at this critical point on examples of spaces of constant curvature and compute the mass gap in the theory, the free energy density (which turns out to be a universal function of the information contained in the geometry of the manifold) and the two-point correlation functions. The results we get give an indication that this model is an example of a three-dimensional analogue of a rational conformal field theory. A conclusion with a brief summary and remarks follows at the end.

  6. Determination of dispersive optical constants of nanocrystalline CdSe (nc-CdSe) thin films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharma, Kriti; Al-Kabbi, Alaa S.; Saini, G.S.S.

    2012-06-15

    Highlights: ► nc-CdSe thin films are prepared by thermal vacuum evaporation technique. ► TEM analysis shows NCs are spherical in shape. ► XRD reveals the hexagonal (wurtzite) crystal structure of nc-CdSe thin films. ► The direct optical bandgap of nc-CdSe is 2.25 eV in contrast to bulk (1.7 eV). ► Dispersion of refractive index is discussed in terms of Wemple–DiDomenico single oscillator model. -- Abstract: The nanocrystalline thin films of CdSe are prepared by thermal evaporation technique at room temperature. These thin films are characterized by transmission electron microscopy (TEM), scanning electron microscopy (SEM), energy dispersive X-ray analysis (EDX), X-raymore » diffraction (XRD) and photoluminescence spectroscopy (PL). The transmission spectra are recorded in the transmission range 400–3300 nm for nc-CdSe thin films. Transmittance measurements are used to calculate the refractive index (n) and absorption coefficient (α) using Swanepoel's method. The optical band gap (E{sub g}{sup opt}) has been determined from the absorption coefficient values using Tauc's procedure. The optical constants such as extinction coefficient (k), real (ε{sub 1}) and imaginary (ε{sub 2}) dielectric constants, dielectric loss (tan δ), optical conductivity (σ{sub opt}), Urbach energy (E{sub u}) and steepness parameter (σ) are also calculated for nc-CdSe thin films. The normal dispersion of refractive index is described using Wemple–DiDomenico single-oscillator model. Refractive index dispersion is further analysed to calculate lattice dielectric constant (ε{sub L}).« less

  7. The Auckland Cataract Study: co-morbidity, surgical techniques, and clinical outcomes in a public hospital service

    PubMed Central

    Riley, Andrew F; Malik, Tahira Y; Grupcheva, Christina N; Fisk, Michael J; Craig, Jennifer P; McGhee, Charles N

    2002-01-01

    Aim: To prospectively assess cataract surgery in a major New Zealand public hospital by defining presenting clinical parameters and surgical and clinical outcomes in a cohort of subjects just below threshold for treatment, based upon a points based prioritisation system. Methods: The prospective observational study comprised 488 eyes of 480 subjects undergoing consecutive cataract operations at Auckland Hospital. All subjects underwent extensive ophthalmic examination before and after surgery. Details of the surgical procedure, including any intraoperative difficulties or complications, were documented. Postoperative review was performed at 1 day and 4 weeks after surgery. Demographic data, clinical outcomes, and adverse events were correlated by an independent assessor. Results: The mean age at surgery was 74.9 (SD 9.6) years with a female predominance (62%). Significant systemic disease affected 80% of subjects, with 20% of the overall cohort exhibiting diabetes mellitus. 26% of eyes exhibited coexisting ocular disease and in 7.6% this affected best spectacle corrected visual acuity (BSCVA). A mean spherical equivalent of −0.49 (1.03) D and mean BSCVA of 0.9 (0.6) log MAR units (Snellen equivalent approximately 6/48) was noted preoperatively. Local anaesthesia was employed in 99.8% of subjects (94.9% sub-Tenon's). The majority of procedures (97.3%) were small incision phacoemulsification with foldable lens implant. Complications included: 4.9% posterior capsule tears, 3.8% cystoid macular oedema, and one case (0.2%) of endophthalmitis. Mean BSCVA after surgery was 0.1 (0.2) log MAR units (6/7.5 Snellen equivalent), with a mean spherical equivalent of −0.46 (0.89) D, and was 6/12 or better in 88% of all eyes. A drop in BSCVA, thought to be directly attributable to the surgical intervention, was recorded in a small percentage of eyes (1.5%) after surgery. Conclusion: This study provides a representative assessment of the management of cataract in the New Zealand public hospital system. A predominantly elderly, female population, frequently exhibiting significant systemic illness and coexisting ocular disease, relatively advanced cataracts, and poor BSCVA, presented for cataract surgery. The majority of subjects underwent small incision, phacoemulsification, day case surgery. While almost 90% achieved at least 6/12 BSCVA post-surgery, approximately 5% sustained an adverse intraoperative event and 1.5% of eyes exhibited a reduction in BSCVA postoperatively. PMID:11815345

  8. The Auckland Cataract Study: 2 year postoperative assessment of aspects of clinical, visual, corneal topographic and satisfaction outcomes

    PubMed Central

    Thompson, A M; Sachdev, N; Wong, T; Riley, A F; Grupcheva, C N; McGhee, C N

    2004-01-01

    Aim: To assess clinical, visual, computerised corneal topographic, and subjective satisfaction with visual acuity, in a cohort of subjects 2 years after phacoemulsification surgery in a public hospital in New Zealand. Methods: Prospective study of a representative sample of 97 subjects (20%) randomly selected from 480 subjects in the original Auckland Cataract Study (ACS) cohort. The clinical assessment protocol was identical to the ACS and included an extensive questionnaire to enable direct comparisons to be made between the two groups. Results: The study population was predominantly female (66%) with a mean age of 76.3 (SD 9.9) years. New systemic and ocular disease affected 18.4% and 10.3% of subjects respectively, and 10.3% required referral to either a general practitioner (2.1%) or ophthalmologist (8.2%). Mean best spectacle corrected visual acuity (BSCVA) was 0.2 (0.2) logMAR units (6/9 Snellen equivalent), with mean spherical equivalent −0.37 (1.01) dioptres (D) and astigmatism −1.07 (0.70) D 2 years postoperatively, compared to mean BSCVA 0.1 (0.2) logMAR units (6/7.5 Snellen equivalent), spherical equivalent −0.59 (1.07) D, and astigmatism −1.14 (0.77) D 4 weeks after surgery. 94.9% of subjects retained a BSCVA of 6/12 or better, irrespective of pre-existing ocular disease. The overall posterior capsule opacification (PCO) rate was 20.4% and this was visually insignificant in all but 3.1% of eyes that had already undergone Nd:YAG posterior capsulotomy. Orbscan II elevation technology demonstrated corneal stability 2 years after uncomplicated phacoemulsification. Although corneal astigmatism was eliminated in approximately half of the subjects 1 month postoperatively, astigmatism showed a tendency to regress towards the preoperative level with local corneal thickening at the site of incision 2 years after cataract surgery. Of fellow eyes, 61.2% had undergone cataract surgery. Overall, 75.3% of subjects were moderately to very satisfied with their current level of visual acuity. Conclusion: Two years after cataract surgery subjects are generally satisfied with their current level of vision and distance BSCVA is 6/12 or better in the majority of eyes. Although only a minority of eyes develop sufficient PCO to require capsulotomy 10.3% of eyes develop new vision threatening ocular pathology. PMID:15258022

  9. Feasibility of measuring selenium in humans using in vivo neutron activation analysis.

    PubMed

    Tahir, S N A; Chettle, D R; Byun, S H; Prestwich, W V

    2015-11-01

    Selenium (Se) is an element that, in trace quantities, plays an important role in the normal function of a number of biological processes in humans. Many studies have demonstrated that selenium deficiency in the body may contribute to an increased risk for certain neoplastic, cardiovascular, osseous, and nervous system diseases including retardation of bone formation. However, at higher concentrations Se is cytotoxic. For these reasons it is desirable to have a means of monitoring selenium concentration in humans.This paper presents the outcome of a feasibility study carried out for measuring selenium in humans using in vivo neutron activation analysis (IVNAA). In this technique a small dose of neutrons is delivered to the organ of interest, the neutrons are readily captured by the target nuclei, and the γ-rays given off are detected outside of the body. For the present study, human hand (bone) tissue equivalent phantoms were prepared with varying amounts of Se. These were irradiated by a low energy fast neutron beam produced by the (7)Li(p,n)(7)Be reaction employing the high beam current Tandetron accelerator. The counting data saved using a 4π NaI(TI) detection system were analyzed. The selenium was detected via the neutron capture reaction, (76)Se(n,γ)(77 m)Se, whereas calcium was detected through the (48)Ca(n,γ)(49)Ca reaction for the purpose of normalization of the Se signals to the calcium signals. From the calibration lines drawn between Se/Ca concentrations and Se/Ca counts ratio, the minimum detection limits (MDLs) were computed for two sets of phantoms irradiated under different irradiation parameters.In this study the optimized MDL value was determined to be 81 ng g(-1) (Se/phantom mass) for an equivalent dose of 188 mSv to the phantom. This MDL was found at least 10 times lower than the reported data on Se concentration measured in bone tissues. It was concluded that the NAA technique would be a feasible means of performing in vivo measurements of selenium in humans. Currently the data on in vivo measurement of selenium in humans are limited; the results of the present study would greatly contribute to the present data.

  10. Structural, morphological and optical properties of ZnSe quantum dot thin films.

    PubMed

    Zedan, I T; Azab, A A; El-Menyawy, E M

    2016-02-05

    ZnSe powder was prepared via hydrothermal technique using zinc acetate and sodium selenite as source materials. The prepared ZnSe powder was used for preparing film with different thickness values (95, 135 and 230 nm) via thermal evaporation technique. X-ray diffraction showed that the prepared powder has cubic zinc-blende structure with a space group, F43m. The high resolution transmittance electron microscope results show that the films are composed of spherical-shaped nanoparticles with a diameter in the range of 2-8 nm. The optical properties of ZnSe films with differing thicknesses are investigated by means of spectrophotometric measurements of the photoluminescence, transmittance and reflectance. The absorption coefficient of the films is calculated and the optical band gap is estimated. The refractive index of the films is determined and its normal dispersion behavior is analyzed on the basis of a single oscillator model, in which oscillator energy, dispersion energy and dielectric constant at high frequency are evaluated. Drude model is also applied to determine the lattice dielectric constant and the ratio of the carriers' concentration to their effective mass. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Anti-biofilm activity of biogenic selenium nanoparticles and selenium dioxide against clinical isolates of Staphylococcus aureus, Pseudomonas aeruginosa, and Proteus mirabilis.

    PubMed

    Shakibaie, Mojtaba; Forootanfar, Hamid; Golkari, Yaser; Mohammadi-Khorsand, Tayebe; Shakibaie, Mohammad Reza

    2015-01-01

    The aim of the present study was to investigate the anti-biofilm activity of biologically synthesized selenium nanoparticles (Se NPs) against the biofilm produced by clinically isolated bacterial strains compared to that of selenium dioxide. Thirty strains of Staphylococcus aureus, Pseudomonas aeruginosa, and Proteus mirabilis were isolated from various specimens of the patients hospitalized in different hospitals (Kerman, Iran). Quantification of the biofilm using microtiter plate assay method introduced 30% of S. aureus, 13% of P. aeruginosa and 17% of P. mirabilis isolates as severely adherent strains. Transmission electron micrograph (TEM) of the purified Se NPs (produced by Bacillus sp. MSh-1) showed individual and spherical nano-structure in the size range of 80-220nm. Obtained results of the biofilm formation revealed that selenium nanoparticles inhibited the biofilm of S. aureus, P. aeruginosa, and P. mirabilis by 42%, 34.3%, and 53.4%, respectively, compared to that of the non-treated samples. Effect of temperature and pH on the biofilm formation in the presence of Se NPs and SeO2 was also evaluated. Copyright © 2014 Elsevier GmbH. All rights reserved.

  12. Design of a head phantom produced on a 3D rapid prototyping printer and comparison with a RANDO and 3M lucite head phantom in eye dosimetry applications

    NASA Astrophysics Data System (ADS)

    Homolka, Peter; Figl, Michael; Wartak, Andreas; Glanzer, Mathias; Dünkelmeyer, Martina; Hojreh, Azadeh; Hummel, Johann

    2017-04-01

    An anthropomorphic head phantom including eye inserts allowing placement of TLDs 3 mm below the cornea has been produced on a 3D printer using a photo-cured acrylic resin to best allow tissue equivalence. Thus Hp(3) can be determined in radiological and interventional photon radiation fields. Eye doses and doses to the forehead have been compared to an Alderson RANDO head and a 3M Lucite skull phantom in terms of surface dose per incident air kerma for frontal irradiation since the commercial phantoms do not allow placement of TLDs 3 mm below the corneal surface. A comparison of dose reduction factors (DRFs) of a common lead glasses model has also been performed. Eye dose per incident air kerma were comparable between all three phantoms (printed phantom: 1.40, standard error (SE) 0.04; RANDO: 1.36, SE 0.03; 3M: 1.37, SE 0.03). Doses to the forehead were identical to eye surface doses for the printed phantom and the RANDO head (ratio 1.00 SE 0.04, and 0.99 SE 0.03, respectively). In the 3M Lucite skull phantom dose on the forehead was 15% lower than dose to the eyes attributable to phantom properties. DRF of a sport frame style leaded glasses model with 0.75 mm lead equivalence measured were 6.8 SE 0.5, 9.3 SE 0.4 and 10.5 SE 0.5 for the RANDO head, the printed phantom, and the 3M Lucite head phantom, respectively, for frontal irradiation. A comparison of doses measured in 3 mm depth and on the surface of the eyes in the printed phantom revealed no difference larger than standard errors from TLD dosimetry. 3D printing offers an interesting opportunity for phantom design with increasing potential as printers allowing combinations of tissue substitutes will become available. Variations between phantoms may provide a useful indication of uncertainty budgets when using phantom measurements to estimate individual personnel doses.

  13. Design of a head phantom produced on a 3D rapid prototyping printer and comparison with a RANDO and 3M lucite head phantom in eye dosimetry applications.

    PubMed

    Homolka, Peter; Figl, Michael; Wartak, Andreas; Glanzer, Mathias; Dünkelmeyer, Martina; Hojreh, Azadeh; Hummel, Johann

    2017-04-21

    An anthropomorphic head phantom including eye inserts allowing placement of TLDs 3 mm below the cornea has been produced on a 3D printer using a photo-cured acrylic resin to best allow tissue equivalence. Thus H p (3) can be determined in radiological and interventional photon radiation fields. Eye doses and doses to the forehead have been compared to an Alderson RANDO head and a 3M Lucite skull phantom in terms of surface dose per incident air kerma for frontal irradiation since the commercial phantoms do not allow placement of TLDs 3 mm below the corneal surface. A comparison of dose reduction factors (DRFs) of a common lead glasses model has also been performed. Eye dose per incident air kerma were comparable between all three phantoms (printed phantom: 1.40, standard error (SE) 0.04; RANDO: 1.36, SE 0.03; 3M: 1.37, SE 0.03). Doses to the forehead were identical to eye surface doses for the printed phantom and the RANDO head (ratio 1.00 SE 0.04, and 0.99 SE 0.03, respectively). In the 3M Lucite skull phantom dose on the forehead was 15% lower than dose to the eyes attributable to phantom properties. DRF of a sport frame style leaded glasses model with 0.75 mm lead equivalence measured were 6.8 SE 0.5, 9.3 SE 0.4 and 10.5 SE 0.5 for the RANDO head, the printed phantom, and the 3M Lucite head phantom, respectively, for frontal irradiation. A comparison of doses measured in 3 mm depth and on the surface of the eyes in the printed phantom revealed no difference larger than standard errors from TLD dosimetry. 3D printing offers an interesting opportunity for phantom design with increasing potential as printers allowing combinations of tissue substitutes will become available. Variations between phantoms may provide a useful indication of uncertainty budgets when using phantom measurements to estimate individual personnel doses.

  14. The relationship between central corneal thickness and optic disc size in patients with primary open-angle glaucoma in a hospital-based population.

    PubMed

    Terai, Naim; Spoerl, Eberhard; Pillunat, Lutz E; Kuhlisch, Eberhard; Schmidt, Eckart; Boehm, Andreas G

    2011-09-01

    To investigate the relationship between central corneal thickness (CCT) and optic disc size in patients with primary open-angle glaucoma (POAG) in a hospital-based population. Data for the right eyes of 1435 White patients with POAG were included in a retrospective hospital-based study. All eyes underwent optic nerve head imaging using Heidelberg Retina Tomograph II (HRT II; Heidelberg Engineering, Heidelberg, Germany) and CCT measurement by ultrasound corneal pachymetry. Eyes with prior intraocular or corneal surgery were excluded. Low-quality HRT II images were also excluded. The impact of age, gender, CCT, intraocular pressure, cylindrical and spherical refractive error as independent factors on optic disc size was investigated in a multiple linear regression analysis. The data for 1104 right eyes qualified for participation in the study. The median age of these patients was 65 years. The median CCT was 547 μm (25th-75th percentile 522-575 μm). The median optic disc size was 2.21 mm(2) (25th-75th percentile 1.89-2.60 mm(2)). Multiple linear regression analysis revealed that age (p = 0.001), CCT (p = 0.001) and spherical equivalent (p = 0.049) were correlated to disc size according to the following formula: disc area = -0.004 × age - 0.001 × CCT - 0.014 × spherical equivalent +3.290. R(2) of the whole model was 0.021. Univariate regression analysis between age and disc area provided R(2) = 0.008 with p = 0.002. Univariate regression analysis between disc area and CCT provided R(2) = 0.005 with p = 0.02. In this retrospective hospital-based study we could not detect a clinically relevant correlation between optic disc size and CCT. The correlation between CCT and disc size and between age and disc size were statistically significant, but the R(2) values were very low. The results of the study are biased because of its hospital-based design, so the results of the study need to be confirmed in a large population-based study. © 2009 The Authors. Journal compilation © 2009 Acta Ophthalmol.

  15. Effects of surface coating of Y(OH) 3 on the electrochemical performance of spherical Ni(OH) 2

    NASA Astrophysics Data System (ADS)

    Fan, Jing; Yang, Yifu; Yu, Peng; Chen, Weihua; Shao, Huixia

    The effects of surface coating of Y(OH) 3 on the electrochemical performance of spherical Ni(OH) 2 were studied by cyclic voltammetry (CV) with soft-embedded electrode (SE-E). The coating was performed by chemical surface precipitation under different conditions. The structure, morphology, chemical composition and electrochemical properties of two different samples with surface coating of Y(OH) 3 were characterized and compared. The results show that a two-step oxidation process exists in the oxidation procedure of spherical Ni(OH) 2 corresponding to the formation of Ni(III) and Ni(IV), respectively. The conversion of Ni(III) to Ni(IV) is regarded as a side reaction in which Ni(IV) species is not stable. The presence of Y(OH) 3 on the particle surface can restrain the side reactions, especially the formation of Ni(IV). The application of coated Ni(OH) 2 to sealed Ni-MH batteries yielded a charge acceptance of about 88% at 60 °C. The results manifest that the high-temperature performance of Ni(OH) 2 electrode is related to the distribution of the adding elements in surface oxide layer of Ni(OH) 2, the sample with dense and porous coating surface, larger relative surface content and higher utilization ratio of yttrium is more effective.

  16. Irregular Astigmatism After Corneal Transplantation--Efficacy and Safety of Topography-Guided Treatment.

    PubMed

    Laíns, Inês; Rosa, Andreia M; Guerra, Marta; Tavares, Cristina; Lobo, Conceição; Silva, Maria F L; Quadrado, Maria J; Murta, Joaquim N

    2016-01-01

    To analyze the efficacy and safety of topography-guided photorefractive keratectomy (TG-PRK) to treat irregular astigmatism after corneal transplantation. This was a retrospective observational case series. Eyes with irregular astigmatism after penetrating keratoplasty treated with TG-PRK (Allegretto Wave Eye-Q) with the topography-guided customized ablation treatment protocol were included. All treatments had been planned to correct the topographic irregularities, as well as to reduce the refractive error after neutralizing the induced refractive change. Clinical records, treatment plan, and the examinations performed were reviewed and the following data were collected: corrected and uncorrected distance visual acuities; manifest refraction; topographic parameters, and corneal endothelial cell count. We included 31 eyes [30 patients; mean age 45.0 ± 13.4 (SD) years]. At the last postoperative follow-up (mean 9.2 ± 8.2 months), we observed a significant improvement in corrected (P = 0.001) and uncorrected distance visual acuities (P < 0.001). There was a gain of ≥1 uncorrected distance visual acuity line in 96.8% (n = 30) of the eyes. Similarly, the refractive parameters also improved (cylinder P < 0.001; spherical equivalent P = 0.002). At the last visit, 54.8% (n = 17) of the patients presented a spherical equivalent of ±1 D. The 3-mm topographic irregularity also decreased significantly (P < 0.001). There was no significant variation of the corneal endothelial cell count. This is the largest case series of TG-PRK to treat irregular astigmatism in postcorneal transplantation eyes. Our results confirm that TG-PRK is an efficient treatment, associated with significant improvements of both visual acuity and refractive parameters.

  17. Clinical Assessment of Mirror Artifacts in Spectral-Domain Optical Coherence Tomography

    PubMed Central

    Ho, Joseph; Castro, Dinorah P. E.; Castro, Leonardo C.; Chen, Yueli; Liu, Jonathan; Mattox, Cynthia; Krishnan, Chandrasekharan; Fujimoto, James G.; Schuman, Joel S.

    2010-01-01

    Purpose. To investigate the characteristics of a spectral-domain optical coherence tomography (SD-OCT) image phenomenon known as the mirror artifact, calculate its prevalence, analyze potential risk factors, measure severity, and correlate it to spherical equivalent and central visual acuity (VA). Methods. OCT macular cube 512 × 128 scans taken between January 2008 and February 2009 at the New England Eye Center were analyzed for the presence of mirror artifacts. Artifact severity was determined by the degree of segmentation breakdown that it caused on the macular map. A retrospective review was conducted of the medical records of patients with artifacts and of a random control group without artifacts. Results. Of 1592 patients, 9.3% (148 patients, 200 eyes) had scans that contained mirror artifacts. A significantly more myopic spherical equivalent (P < 0.001), worse VA (P < 0.001), longer axial lengths (P = 0.004), and higher proportions of moderate to high myopia (P < 0.001) were found in patients with mirror artifacts than in patients without artifacts. Worse VA was associated with increased artifact severity (P = 0.04). Conclusions. In all scans analyzed, a high prevalence of mirror artifacts was found. This image artifact was often associated with patients with moderate to high myopia. Improvements in instrumentation may be necessary to resolve this problem in moderately and highly myopic eyes. Operators should be advised to properly position the retina when scanning eyes. In cases in which peripheral abnormalities in topographic measurements of retinal thickness are found, corresponding OCT scans should be examined for the presence of mirror artifacts. PMID:20181840

  18. The Relationship between Crystalline Lens Power and Refractive Error in Older Chinese Adults: The Shanghai Eye Study

    PubMed Central

    He, Jiangnan; Lu, Lina; He, Xiangui; Xu, Xian; Du, Xuan; Zhang, Bo; Zhao, Huijuan; Sha, Jida; Zhu, Jianfeng; Zou, Haidong; Xu, Xun

    2017-01-01

    Purpose To report calculated crystalline lens power and describe the distribution of ocular biometry and its association with refractive error in older Chinese adults. Methods Random clustering sampling was used to identify adults aged 50 years and above in Xuhui and Baoshan districts of Shanghai. Refraction was determined by subjective refraction that achieved the best corrected vision based on monocular measurement. Ocular biometry was measured by IOL Master. The crystalline lens power of right eyes was calculated using modified Bennett-Rabbetts formula. Results We analyzed 6099 normal phakic right eyes. The mean crystalline lens power was 20.34 ± 2.24D (range: 13.40–36.08). Lens power, spherical equivalent, and anterior chamber depth changed linearly with age; however, axial length, corneal power and AL/CR ratio did not vary with age. The overall prevalence of hyperopia, myopia, and high myopia was 48.48% (95% CI: 47.23%–49.74%), 22.82% (95% CI: 21.77%–23.88%), and 4.57% (95% CI: 4.05–5.10), respectively. The prevalence of hyperopia increased linearly with age while lens power decreased with age. In multivariate models, refractive error was strongly correlated with axial length, lens power, corneal power, and anterior chamber depth; refractive error was slightly correlated with best corrected visual acuity, age and sex. Conclusion Lens power, hyperopia, and spherical equivalent changed linearly with age; Moreover, the continuous loss of lens power produced hyperopic shifts in refraction in subjects aged more than 50 years. PMID:28114313

  19. Comparison of self-refraction using a simple device, USee, with manifest refraction in adults.

    PubMed

    Annadanam, Anvesh; Varadaraj, Varshini; Mudie, Lucy I; Liu, Alice; Plum, William G; White, J Kevin; Collins, Megan E; Friedman, David S

    2018-01-01

    The USee device is a new self-refraction tool that allows users to determine their own refractive error. We evaluated the ease of use of USee in adults, and compared the refractive error correction achieved with USee to clinical manifest refraction. Sixty adults with uncorrected visual acuity <20/30 and spherical equivalent between -6.00 and +6.00 diopters completed manifest refraction and self-refraction. Subjects had a mean (±SD) age of 53.1 (±18.6) years, and 27 (45.0%) were male. Mean (±SD) spherical equivalent measured by manifest refraction and self-refraction were -0.90 D (±2.53) and -1.22 diopters (±2.42), respectively (p = 0.001). The proportion of subjects correctable to ≥20/30 in the better eye was higher for manifest refraction (96.7%) than self-refraction (83.3%, p = 0.005). Failure to achieve visual acuity ≥20/30 with self-refraction in right eyes was associated with increasing age (per year, OR: 1.05; 95% CI: 1.00-1.10) and higher cylindrical power (per diopter, OR: 7.26; 95% CI: 1.88-28.1). Subjectively, 95% of participants thought USee was easy to use, 85% thought self-refraction correction was better than being uncorrected, 57% thought vision with self-refraction correction was similar to their current corrective lenses, and 53% rated their vision as "very good" or "excellent" with self-refraction. Self-refraction provides acceptable refractive error correction in the majority of adults. Programs targeting resource-poor settings could potentially use USee to provide easy on-site refractive error correction.

  20. Autorefraction, Retinoscopy, Javal's Rule, and Grosvenor's Modified Javal's Rule: The Best Predictor of Refractive Astigmatism

    PubMed Central

    Asiedu, Kofi; Ampiah, Emmanuel Ekow

    2016-01-01

    The aim of the study was to determine the level of agreement between Javal's rule, autorefraction, retinoscopy, and refractive astigmatism and to determine which technique is the most suitable substitute when subjective refraction is not applicable using a clinical sample. A total of 36 subjects, 14 males and 22 females, were involved in this study. The intraclass correlation coefficients between subjective refraction, autorefraction, and retinoscopy were 0.895 and 0.989, respectively, for the spherical equivalent. The Bland-Altman 95% limits of agreement between subjective refraction and autorefraction; subjective refraction and retinoscopy; and autorefraction and retinoscopy were −2.84 to 3.58, −0.88 to 1.12, and −3.01 to 3.53, respectively, for the spherical equivalent. The intraclass correlation coefficients between spectacle total astigmatism and the following techniques were as follows: retinoscopy (0.85); autorefraction (0.92); Javal's rule (0.82); and Grosvenor et al. version (0.85). The Bland-Altman 95% limits of agreement between subjective refraction and autorefraction; subjective refraction and retinoscopy; subjective refraction and Javal's rule; and subjective refraction and Grosvenor et al. version were −0.87 to 1.25, −1.49 to 1.99, −0.73 to 1.93, and −0.89 to 1.7, respectively, for the total astigmatism. The study showed that autorefraction and Javal's rule may provide a starting point for subjective refraction cylinder power determination but only retinoscopy may satisfactorily replace subjective refraction total astigmatism when subjective refraction is not applicable. PMID:27803811

  1. Trial Frame Refraction versus Autorefraction among New Patients in a Low-Vision Clinic

    PubMed Central

    DeCarlo, Dawn K.; McGwin, Gerald; Searcey, Karen; Gao, Liyan; Snow, Marsha; Waterbor, John; Owsley, Cynthia

    2013-01-01

    Purpose. To determine the relationship between refractive error as measured by autorefraction and that measured by trial frame refraction among a sample of adults with vision impairment seen in a university-based low-vision clinic and to determine if autorefraction might be a suitable replacement for trial frame refraction. Methods. A retrospective chart review of all new patients 19 years or older seen over an 18-month period was conducted and the following data collected: age, sex, primary ocular diagnosis, entering distance visual acuity, habitual correction, trial frame refraction, autorefraction, and distance visual acuity measured after trial frame refraction. Trial frame refraction and autorefraction were compared using paired t-tests, intraclass correlations, and Bland-Altman plots. Results. Final analyses included 440 patients for whom both trial frame refraction and autorefraction data were available for the better eye. Participants were mostly female (59%) with a mean age of 68 years (SD = 20). Age-related macular degeneration was the most common etiology for vision impairment (44%). Values for autorefraction and trial frame refraction were statistically different, but highly correlated for the spherical equivalent power (r = 0.92), the cylinder power (r = 0.80) and overall blurring strength (0.89). Although the values of the cross-cylinders J0 and J45 were similar, they were poorly correlated (0.08 and 0.15, respectively). The range of differences in spherical equivalent power was large (−8.6 to 4.9). Conclusions. Autorefraction is highly correlated with trial frame refraction. Differences are sometimes substantial, making autorefraction an unsuitable substitute for trial frame refraction. PMID:23188726

  2. Effectiveness study of atropine for progressive myopia in Europeans.

    PubMed

    Polling, J R; Kok, R G W; Tideman, J W L; Meskat, B; Klaver, C C W

    2016-07-01

    PurposeRandomized controlled trials have shown the efficacy of atropine for progressive myopia, and this treatment has become the preferred pattern for this condition in Taiwan. This study explores the effectiveness of atropine 0.5% treatment for progressive high myopia and adherence to therapy in a non-Asian country.MethodsAn effectiveness study was performed in Rotterdam, the Netherlands. Overall 77 children (mean age 10.3 years±2.3), of European (n=53), Asian (n=18), and African (n=6) descent with progressive myopia were prescribed atropine 0.5% eye drops daily. Both parents and children filled in a questionnaire regarding adverse events and adherence to therapy. A standardized eye examination including cycloplegic refraction and axial length was performed at baseline and 1, 4, and 12 months after initiation of therapy.ResultsMean spherical equivalent at baseline was -6.6D (±3.3). The majority (60/77, 78%) of children adhered to atropine treatment for 12 months; 11 of the 17 children who discontinued therapy did so within 1 month after the start of therapy. The most prominent reported adverse events were photophobia (72%), followed by reading problems (38%), and headaches (22%). The progression rate of spherical equivalent before treatment (-1.0D/year±0.7) diminished substantially during treatment (-0.1D/year±0.7) compared to those who ceased therapy (-0.5D/year±0.6; P=0.03).ConclusionsDespite the relatively high occurrence of adverse events, our study shows that atropine can be an effective and sustainable treatment for progressive high myopia in Europeans.

  3. Safety, efficacy, predictability and stability of laser in situ keratomileusis (LASIK) with a 1000-Hz scanning spot excimer laser.

    PubMed

    Khoramnia, Ramin; Salgado, Josefina P; Wuellner, Christian; Donitzky, Christof; Lohmann, Chris P; Winkler von Mohrenfels, Christoph

    2012-09-01

    To evaluate the safety, efficacy, predictability and stability of laser in situ keratomileusis (LASIK) with a 1000-Hz scanning spot excimer laser (Concept System 1000; WaveLight GmbH, Erlangen, Germany). LASIK was performed on twenty eyes with myopia or myopic astigmatism (mean spherical equivalent refraction: -3.97±1.72 dioptres (D); mean cylinder: -0.84±0.77 D) using a microkeratome for flap creation and the Concept System 1000 for photoablation. Patients were examined preoperatively as well as 1, 3 and 6 months after the treatment. Manifest sphere and cylinder, uncorrected (UCDVA) and best corrected (BCDVA) distance visual acuity, corneal topography and pachymetry were analysed. We observed no adverse events that might have been associated with the use of a repetition rate of 1000 Hz. All eyes maintained or had improved BCDVA at 6 months after treatment when compared to preoperative values. Six months after LASIK, UCDVA was 20/20 or better in 85% and 20/25 or better in 100% of the eyes. The spherical equivalent refraction was within ±0.50 D in 95% of the eyes at 6 months after surgery. The refraction stayed stable over time; 95% of the eyes changed<0.5 D postoperatively. LASIK with the prototype 1000-Hz excimer laser was safe, efficient and predictable. The postoperative refraction was stable over time. There were no specific clinical side-effects that might be associated with the use of such a high repetition rate. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.

  4. Relative Proportion Of Different Types Of Refractive Errors In Subjects Seeking Laser Vision Correction.

    PubMed

    Althomali, Talal A

    2018-01-01

    Refractive errors are a form of optical defect affecting more than 2.3 billion people worldwide. As refractive errors are a major contributor of mild to moderate vision impairment, assessment of their relative proportion would be helpful in the strategic planning of health programs. To determine the pattern of the relative proportion of types of refractive errors among the adult candidates seeking laser assisted refractive correction in a private clinic setting in Saudi Arabia. The clinical charts of 687 patients (1374 eyes) with mean age 27.6 ± 7.5 years who desired laser vision correction and underwent a pre-LASIK work-up were reviewed retrospectively. Refractive errors were classified as myopia, hyperopia and astigmatism. Manifest refraction spherical equivalent (MRSE) was applied to define refractive errors. Distribution percentage of different types of refractive errors; myopia, hyperopia and astigmatism. The mean spherical equivalent for 1374 eyes was -3.11 ± 2.88 D. Of the total 1374 eyes, 91.8% (n = 1262) eyes had myopia, 4.7% (n = 65) eyes had hyperopia and 3.4% (n = 47) had emmetropia with astigmatism. Distribution percentage of astigmatism (cylinder error of ≥ 0.50 D) was 78.5% (1078/1374 eyes); of which % 69.1% (994/1374) had low to moderate astigmatism and 9.4% (129/1374) had high astigmatism. Of the adult candidates seeking laser refractive correction in a private setting in Saudi Arabia, myopia represented greatest burden with more than 90% myopic eyes, compared to hyperopia in nearly 5% eyes. Astigmatism was present in more than 78% eyes.

  5. Prevalence of refractive errors in children in Equatorial Guinea.

    PubMed

    Soler, Margarita; Anera, Rosario G; Castro, José J; Jiménez, Raimundo; Jiménez, José R

    2015-01-01

    The aim of this work is to evaluate the epidemiological aspects of the refractive errors in school-aged children in Malabo (Island of Bioko), Equatorial Guinea (western-central Africa). A total of 425 schoolchildren (209 male subjects and 216 female subjects, aged between 6 and 16 years) were examined to evaluate their refraction errors in Malabo, Equatorial Guinea (western-central Africa). The examination included autorefraction with cycloplegia, measurement of visual acuity (VA) for far vision, and the curvature radii of the main meridians of the anterior surface of the cornea. A low prevalence of myopia was found (≤-0.50 diopters [D] spherical equivalent), with unilateral and bilateral myopia being 10.4 and 5.2%, respectively. The prevalence of unilateral and bilateral hypermetropia (≥2.0 D spherical equivalent) was 3.1 and 1.6%, respectively. Astigmatism (≤-0.75 D) was found in unilateral form in 32.5% of these children, whereas bilateral astigmatism was found in 11.8%. After excluding children having any ocular pathology, the low prevalence of high refractive errors signified good VA in these children. Significant differences were found in the distribution of the refractive errors by age and type of schooling (public or private) but not by sex. In general, the radii of the anterior of the cornea did not vary significantly with age. The mean refractive errors found were low and therefore VA was high in these children. There was a low prevalence of myopia, with significantly higher values in those who attended private schools (educationally and socioeconomically more demanding). Astigmatism was the most frequent refractive error.

  6. Refractive error among the elderly in rural Southern Harbin, China.

    PubMed

    Li, Zhijian; Sun, Dianjun; Cuj, Hao; Zhang, Liqiong; Lju, Ping; Yang, Hongbin; Baj, Jie

    2009-01-01

    To estimate the prevalence and associated factors of refractive errors among the elderly in a rural area of Southern Harbin, China. Five thousand and fifty seven subjects (age > or = 50 years) were enumerated for a population-based study. All participants underwent complete ophthalmic evaluation. Refraction was performed by ophthalmic personnel trained in the study procedures. Myopia was defined as spherical equivalent worse than -0.50 diopters (D) and hyperopia as spherical equivalent worse than +0.50 D. Astigmatism was defined as a cylindrical error worse than 0.75D. Association of refractive errors with age, sex, and education were analyzed. Of the 5,057 responders (91.0%), 4,979 were eligible. The mean age was 60.5 (range 50-96) years old. The prevalence of myopia was 9.5% (95% confidence interval [CI], 8.5-10.1) and of hyperopia was 8.9% (95% CI, 7.9-9.5). Astigmatism was evident in 7.6% of the subjects. Myopia, hyperopia and astigmatism increased with increasing age (p<0.001, respectively). Myopia and astigmatism were more common in males, whereas hyperopia was more common in females. We also found that prevalence of refractive error weas associated with education. Myopia was more common in those with higher degrees of education, whereas hyperopia and astigmatism were more common in those with no formal education. This report has provided details of the refractive status in a rural population of Harbin. The prevalence of refractive errors in this population is lower than those reported in other regions of the world.

  7. Prevalence of Visual Impairment among 4- to 6-years-old Children in Khon Kaen City Municipality, Thailand.

    PubMed

    Wongwai, Phanthipha; Anupongongarch, Pacharapan; Suwannaraj, Sirinya; Asawaphureekorn, Somkiat

    2016-08-01

    To evaluate the prevalence of visual impairment of children aged four to six years in Khon Kaen City Municipality, Thailand. The visual acuity test was performed on 1,286 children in kindergarten schools located in Khon Kaen Municipality. The first test of visual acuity was done by trained teachers and the second test by the pediatric ophthalmologist. The prevalence of visual impairment of both tests was recorded including sensitivity, specificity, likelihood ratio, and predictive value of the test by teachers. The causes of visual impairment were also recorded. There were 39 children with visual impairment from the test by the teacher and 12 children from the test by the ophthalmologist. Myopia is the single cause of visual impairment. Mean spherical equivalence is 1.375 diopters (SD = 0.53). Median spherical equivalence is 1.375 diopters (minimum = 0.5, maximum =4). The detection of visual impairment by trained teachers had a sensitivity of 1.00 (95% CI 0.76-1.00), specificity of 0.98 (95% CI 0.97-0.99), likelihood ratio for a positive test 44.58 (95% CI 30.32-65.54), likelihood ratio for a negative test 0.04 (95% CI 0.003-0.60), positive predictive value of 0.31 (95% CI 0.19-0.47), and negative predictive value of 1.00 (95% CI 0.99-1.00). The prevalence of visual impairment among children aged four to six year old is 0.9%. Trained teachers can be examiners for screening purpose.

  8. Determinants of ocular deviation in esotropic subjects under general anesthesia.

    PubMed

    Daien, Vincent; Turpin, Chloé; Lignereux, François; Belghobsi, Riadh; Le Meur, Guylene; Lebranchu, Pierre; Pechereau, Alain

    2013-01-01

    The authors attempted to identify the determinants of ocular deviation in a population of patients with esotropia under general anesthesia. Forty-one patients with esotropia were included. Horizontal ocular deviation was evaluated by the photographic Hirschberg test both in the awakened state and under general anesthesia before surgery. Changes in ocular deviation were measured and a multivariate analysis was used to assess its clinical determinants. The mean age (± standard deviation [SD]) of study subjects was 13 ± 11 years and 51% were females. The mean spherical equivalent refraction of the right eye was 2.44 ± 2.50 diopters (D), with no significant difference between eyes (P = .26). The mean ocular deviation changed significantly, from 33.5 ± 12.5 prism diopters (PD) at preoperative examination to 8.8 ± 11.4 PD under general anesthesia (P = .0001). The changes in ocular deviation positively correlated with the pre-operative ocular deviation (correlation coefficient r = 0.59, P = .0001) and negatively correlated with patient age (correlation coefficient r = -0.53, P = .0001). These two determinants remained significant after multivariate adjustment of the following variables: preoperative ocular deviation; age; gender; spherical equivalent refraction; and number of previous strabismus surgeries (model r(2) = 0.49, P = .0001). The ocular position under general anesthesia was reported as a key factor in the surgical treatment of subjects with esotropia; therefore, its clinical determinants were assessed. The authors observed that preoperative ocular deviation and patient age were the main factors that influenced the ocular position under general anesthesia. Copyright 2013, SLACK Incorporated.

  9. Numerical investigation on the Ångström exponent of black carbon aerosol

    NASA Astrophysics Data System (ADS)

    Li, Ji; Liu, Chao; Yin, Yan; Kumar, K. Raghavendra

    2016-04-01

    Black carbon (BC) plays an important role on the global and regional climate, whereas there are significant uncertainties on its optical properties. Among various optical properties, the Ångström exponent (AE) indicates the spectral variation of the particle-optic interaction and is widely used to understand the aerosol properties. We consider the influence of BC geometry on its optical properties and assess the sensitivity of the AE to particle geometry and size distribution. The fractal aggregates with different fractal dimensions are used to represent realistic BC particles, and popular equivalent volume spherical and spheroidal models are also considered for comparison. Even if the fractal aggregates become highly compact and spherical, their optical properties are still significantly different from those of equivalent volume spheres or spheroids. Meanwhile, the Rayleigh-Debye-Gans approximation can hardly provide accurate results for all optical quantities of aggregates with different dimensions. The extinction Ångström exponent (EAE) and absorption Ångström exponent (AAE) are sensitive to both particle geometry and size distribution. With BC becoming more compact (from fractal aggregate to spheroid and to sphere), the AE becomes more sensitive to particle size distribution. The EAE and AAE of aggregates with different size distributions vary between 1.10-1.63 and 0.87-1.50, respectively, whereas those of the spheres or spheroids have wider ranges. Furthermore, the AE at smaller wavelengths (between 0.35 µm and 0.55 µm) is more sensitive to geometry and size distribution than that given by optical properties at larger wavelengths (between 0.55 µm and 0.88 µm).

  10. Trial frame refraction versus autorefraction among new patients in a low-vision clinic.

    PubMed

    DeCarlo, Dawn K; McGwin, Gerald; Searcey, Karen; Gao, Liyan; Snow, Marsha; Waterbor, John; Owsley, Cynthia

    2013-01-02

    To determine the relationship between refractive error as measured by autorefraction and that measured by trial frame refraction among a sample of adults with vision impairment seen in a university-based low-vision clinic and to determine if autorefraction might be a suitable replacement for trial frame refraction. A retrospective chart review of all new patients 19 years or older seen over an 18-month period was conducted and the following data collected: age, sex, primary ocular diagnosis, entering distance visual acuity, habitual correction, trial frame refraction, autorefraction, and distance visual acuity measured after trial frame refraction. Trial frame refraction and autorefraction were compared using paired t-tests, intraclass correlations, and Bland-Altman plots. Final analyses included 440 patients for whom both trial frame refraction and autorefraction data were available for the better eye. Participants were mostly female (59%) with a mean age of 68 years (SD = 20). Age-related macular degeneration was the most common etiology for vision impairment (44%). Values for autorefraction and trial frame refraction were statistically different, but highly correlated for the spherical equivalent power (r = 0.92), the cylinder power (r = 0.80) and overall blurring strength (0.89). Although the values of the cross-cylinders J(0) and J(45) were similar, they were poorly correlated (0.08 and 0.15, respectively). The range of differences in spherical equivalent power was large (-8.6 to 4.9). Autorefraction is highly correlated with trial frame refraction. Differences are sometimes substantial, making autorefraction an unsuitable substitute for trial frame refraction.

  11. Recent Developments in the Code RITRACKS (Relativistic Ion Tracks)

    NASA Technical Reports Server (NTRS)

    Plante, Ianik; Ponomarev, Artem L.; Blattnig, Steve R.

    2018-01-01

    The code RITRACKS (Relativistic Ion Tracks) was developed to simulate detailed stochastic radiation track structures of ions of different types and energies. Many new capabilities were added to the code during the recent years. Several options were added to specify the times at which the tracks appear in the irradiated volume, allowing the simulation of dose-rate effects. The code has been used to simulate energy deposition in several targets: spherical, ellipsoidal and cylindrical. More recently, density changes as well as a spherical shell were implemented for spherical targets, in order to simulate energy deposition in walled tissue equivalent proportional counters. RITRACKS is used as a part of the new program BDSTracks (Biological Damage by Stochastic Tracks) to simulate several types of chromosome aberrations in various irradiation conditions. The simulation of damage to various DNA structures (linear and chromatin fiber) by direct and indirect effects has been improved and is ongoing. Many improvements were also made to the graphic user interface (GUI), including the addition of several labels allowing changes of units. A new GUI has been added to display the electron ejection vectors. The parallel calculation capabilities, notably the pre- and post-simulation processing on Windows and Linux machines have been reviewed to make them more portable between different systems. The calculation part is currently maintained in an Atlassian Stash® repository for code tracking and possibly future collaboration.

  12. The point spread function of the human head and its implications for transcranial current stimulation

    NASA Astrophysics Data System (ADS)

    Dmochowski, Jacek P.; Bikson, Marom; Parra, Lucas C.

    2012-10-01

    Rational development of transcranial current stimulation (tCS) requires solving the ‘forward problem’: the computation of the electric field distribution in the head resulting from the application of scalp currents. Derivation of forward models has represented a major effort in brain stimulation research, with model complexity ranging from spherical shells to individualized head models based on magnetic resonance imagery. Despite such effort, an easily accessible benchmark head model is greatly needed when individualized modeling is either undesired (to observe general population trends as opposed to individual differences) or unfeasible. Here, we derive a closed-form linear system which relates the applied current to the induced electric potential. It is shown that in the spherical harmonic (Fourier) domain, a simple scalar multiplication relates the current density on the scalp to the electric potential in the brain. Equivalently, the current density in the head follows as the spherical convolution between the scalp current distribution and the point spread function of the head, which we derive. Thus, if one knows the spherical harmonic representation of the scalp current (i.e. the electrode locations and current intensity to be employed), one can easily compute the resulting electric field at any point inside the head. Conversely, one may also readily determine the scalp current distribution required to generate an arbitrary electric field in the brain (the ‘backward problem’ in tCS). We demonstrate the simplicity and utility of the model with a series of characteristic curves which sweep across a variety of stimulation parameters: electrode size, depth of stimulation, head size and anode-cathode separation. Finally, theoretically optimal montages for targeting an infinitesimal point in the brain are shown.

  13. [Clinical results of the aspheric intraocular lens FY-60AD (Hoya) with particular respect to decentration and tilt].

    PubMed

    Mester, U; Heinen, S; Kaymak, H

    2010-09-01

    Aspheric intraocular lenses (IOLs) aim to improve visual function and particularly contrast vision by neutralizing spherical aberration. One drawback of such IOLs is the enhanced sensitivity to decentration and tilt, which can deteriorate image quality. A total of 30 patients who received bilateral phacoemulsification before implantation of the aspheric lens FY-60AD (Hoya) were included in a prospective study. In 25 of the patients (50 eyes) the following parameters could be assessed 3 months after surgery: visual acuity, refraction, contrast sensitivity, pupil size, wavefront errors and decentration and tilt using a newly developed device. The functional results were very satisfying and comparable to results gained with other aspheric IOLs. The mean refraction was sph + 0.1 D (±0.7 D) and cyl 0.6 D (±0.8 D). The spherical equivalent was −0.2 D (±0.6 D). Wavefront measurements revealed a good compensation of the corneal spherical aberration but vertical and horizontal coma also showed opposing values in the cornea and IOL. The assessment of the lens position using the Purkinje meter demonstrated uncritical amounts of decentration and tilt. The mean amount of decentration was 0.2 mm±0.2 mm in the horizontal and vertical directions. The mean amount of tilt was 4.0±2.1° in horizontal and 3.0±2.5° in vertical directions. In a normal dioptric power range the aspheric IOL FY-60AD compensates the corneal spherical aberration very well with only minimal decentration. The slight tilt is symmetrical in both eyes and corresponds to the position of the crystalline lens in young eyes. This may contribute to our findings of compensated corneal coma.

  14. Recording ion channels across soy-extracted lecithin bilayer generated by water-soluble quantum dots

    NASA Astrophysics Data System (ADS)

    Sarma, Runjun; Mohanta, Dambarudhar

    2014-02-01

    We report on the quantum dot (QD)-induced ion channels across a soya-derived lecithin bilayer supported on a laser drilled of ~100 μm aperture of cellulose acetate substrate that separates two electrolytic chambers. Adequate current bursts were observed when the bilayer was subjected to a gating voltage. The voltage-dependent current fluctuation, across the bilayer, was attributed to the insertion of ~20 nm sized water-soluble CdSe QDs, forming nanopores due to their spontaneous aggregation. Apart from a closed state, the first observable conductance levels were found as 6.3 and 11 nS, as for the respective biasing voltages of -10 and -20 mV. The highest observable conductance states, at corresponding voltages were ~14.3 and 21.1 nS. Considering two simplified models, we predict that the non-spherical pores (dnspore) can be a better approximation over spherical nanopores (dspore) for exhibiting a definite conductance level. At times, even dnspore ≤ 4dspore and that the non-spherical nanopores were associated with a smaller No. of QDs than the case for spherical nanopores, for a definite conductance state. It seems like the current events are partly stochastic, possibly due to thermal effects on the aggregated QDs that would form nanopores. The dwell time of the states was predicted in the range of 384-411 μs. The ion channel mechanism in natural phospholipid bilayers over artificial ones will provide a closer account to understand ion transport mechanism in live cells and signaling activity including labelling with fluorescent QDs.

  15. Mechanical Effects of the Surface Ectoderm on Optic Vesicle Morphogenesis in the Chick Embryo

    PubMed Central

    Hosseini, Hadi S.; Beebe, David C.; Taber, Larry A.

    2014-01-01

    Precise shaping of the eye is crucial for proper vision. Here, we use experiments on chick embryos along with computational models to examine the mechanical factors involved in the formation of the optic vesicles (OVs), which grow outward from the forebrain of the early embryo. First, mechanical dissections were used to remove the surface ectoderm (SE), a membrane that contacts the outer surfaces of the OVs. Principal components analysis of OV shapes suggests that the SE exerts asymmetric loads that cause the OVs to flatten and shear caudally during the earliest stages of eye development and later to bend in the caudal and dorsal directions. These deformations cause the initially spherical OVs to become pear-shaped. Exposure to the myosin II inhibitor blebbistatin reduced these effects, suggesting that cytoskeletal contraction controls OV shape by regulating tension in the SE. To test the physical plausibility of these interpretations, we developed 2-D finite-element models for frontal and transverse cross-sections of the forebrain, including frictionless contact between the SE and OVs. With geometric data used to specify differential growth in the OVs, these models were used to simulate each experiment (control, SE removed, no contraction). For each case, the predicted shape of the OV agrees reasonably well with experiments. The results of this study indicate that differential growth in the OV and external pressure exerted by the SE are suffcient to cause the global changes in OV shape observed during the earliest stages of eye development. PMID:25458577

  16. Insights into selenite reduction and biogenesis of elemental selenium nanoparticles by two environmental isolates of Burkholderia fungorum.

    PubMed

    Khoei, Nazanin Seyed; Lampis, Silvia; Zonaro, Emanuele; Yrjälä, Kim; Bernardi, Paolo; Vallini, Giovanni

    2017-01-25

    Microorganisms capable of transforming toxic selenium oxyanions into non-toxic elemental selenium (Se°) may be considered as biocatalysts for the production of selenium nanoparticles (SeNPs), eventually exploitable in different biotechnological applications. Two Burkholderia fungorum strains (B. fungorum DBT1 and B. fungorum 95) were monitored during their growth for both capacity and efficiency of selenite (SeO 3 2- ) reduction and elemental selenium formation. Both strains are environmental isolates in origin: B. fungorum DBT1 was previously isolated from an oil refinery drainage, while B. fungorum 95 has been enriched from inner tissues of hybrid poplars grown in a soil contaminated by polycyclic aromatic hydrocarbons. Our results showed that B. fungorum DBT1 is able to reduce 0.5mM SeO 3 2- to Se° when cultured aerobically in liquid medium at 27°C, while B. fungorum 95 can reduce more than 1mM SeO 3 2- to Se° within 96h under the same growth conditions, with the appearance of SeNPs in cultures of both bacterial strains. Biogenic SeNPs were spherical, with pH-dependent charge and an average hydrodynamic diameter of 170nm and 200nm depending on whether they were produced by B. fungorum 95 or B. fungorum DBT1, respectively. Electron microscopy analyses evidenced that Se nanoparticles occurred intracellularly and extracellularly. The mechanism of SeNPs formation can be tentatively attributed to cytoplasmic enzymatic activation mediated by electron donors. Biogenic nanoparticles were then probably released outside the bacterial cells as a consequence of a secretory process or cell lysis. Nevertheless, formation of elemental selenium nanoparticles under aerobic conditions by B. fungorum DBT1 and B. fungorum 95 is likely due to intracellular reduction mechanisms. Biomedical and other high tech sectors might exploit these biogenic nanoparticles in the near future, once fully characterized and tested for their multiple properties. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Highly luminescent silica-coated CdS/CdSe/CdS nanoparticles with strong chemical robustness and excellent thermal stability

    NASA Astrophysics Data System (ADS)

    Wang, Nianfang; Koh, Sungjun; Jeong, Byeong Guk; Lee, Dongkyu; Kim, Whi Dong; Park, Kyoungwon; Nam, Min Ki; Lee, Kangha; Kim, Yewon; Lee, Baek-Hee; Lee, Kangtaek; Bae, Wan Ki; Lee, Doh C.

    2017-05-01

    We present facile synthesis of bright CdS/CdSe/CdS@SiO2 nanoparticles with 72% of quantum yields (QYs) retaining ca 80% of the original QYs. The main innovative point is the utilization of the highly luminescent CdS/CdSe/CdS seed/spherical quantum well/shell (SQW) as silica coating seeds. The significance of inorganic semiconductor shell passivation and structure design of quantum dots (QDs) for obtaining bright QD@SiO2 is demonstrated by applying silica encapsulation via reverse microemulsion method to three kinds of QDs with different structure: CdSe core and 2 nm CdS shell (CdSe/CdS-thin); CdSe core and 6 nm CdS shell (CdSe/CdS-thick); and CdS core, CdSe intermediate shell and 5 nm CdS outer shell (CdS/CdSe/CdS-SQW). Silica encapsulation inevitably results in lower photoluminescence quantum yield (PL QY) than pristine QDs due to formation of surface defects. However, the retaining ratio of pristine QY is different in the three silica coated samples; for example, CdSe/CdS-thin/SiO2 shows the lowest retaining ratio (36%) while the retaining ratio of pristine PL QY in CdSe/CdS-thick/SiO2 and SQW/SiO2 is over 80% and SQW/SiO2 shows the highest resulting PL QY. Thick outermost CdS shell isolates the excitons from the defects at surface, making PL QY relatively insensitive to silica encapsulation. The bright SiO2-coated SQW sample shows robustness against harsh conditions, such as acid etching and thermal annealing. The high luminescence and long-term stability highlights the potential of using the SQW/SiO2 nanoparticles in bio-labeling or display applications.

  18. SPHERICAL DIE

    DOEpatents

    Livingston, J.P.

    1959-01-27

    A die is presented for pressing powdered materials into a hemispherical shape of uniforin density and wall thickness comprising a fcmale and male die element held in a stationary spaced relation with the space being equivalent to the wall thickness and defining the hemispherical shape, a pressing ring linearly moveable along the male die element, an inlet to fill the space with powdered materials, a guiding system for moving the pressing ring along the male die element so as to press the powdered material and a heating system for heating the male element so that the powdered material is heated while being pressed.

  19. The transmission or scattering of elastic waves by an inhomogeneity of simple geometry: A comparison of theories

    NASA Technical Reports Server (NTRS)

    Sheu, Y. C.; Fu, L. S.

    1983-01-01

    The extended method of equivalent inclusions is applied to study the specific wave problems: (1) the transmission of elastic waves in an infinite medium containing a layer of inhomogeneity, and (2) the scattering of elastic waves in an infinite medium containing a perfect spherical inhomogeneity. Eigenstrains are expanded as a geometric series and a method of integration based on the inhomogeneous Helmholtz operator is adopted. This study compares results, obtained by using limited number of terms in the eigenstrain expansion, with exact solutions for the layer problem and that for a perfect sphere.

  20. Departure of microscopic friction from macroscopic drag in molecular fluid dynamics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hanasaki, Itsuo; Fujiwara, Daiki; Kawano, Satoyuki, E-mail: kawano@me.es.osaka-u.ac.jp

    2016-03-07

    Friction coefficient of the Langevin equation and drag of spherical macroscopic objects in steady flow at low Reynolds numbers are usually regarded as equivalent. We show that the microscopic friction can be different from the macroscopic drag when the mass is taken into account for particles with comparable scale to the surrounding fluid molecules. We illustrate it numerically by molecular dynamics simulation of chloride ion in water. Friction variation by the atomistic mass effect beyond the Langevin regime can be of use in the drag reduction technology as well as the electro or thermophoresis.

Top