Sample records for spinal fixation technical

  1. [Sacral gigantocellular tumor treated with total sacrectomy and spinal-pelvic fixation].

    PubMed

    Savić, Milenko

    2011-09-01

    Total sacrectomy with spinal-pelvic fixation is considered to be a successful approach to the radical surgical treatment of extensive sacral tumors, however, technically very demanding, thus only rarely reported in the literature. We presented a patient with sacral gigantocellular tumor managed successfully using this method but with certain standard operative techniques improvements. A 30-year old patient with a pronounced painful syndrome and sphincter disorders was confirmed to have sacral gigantocellular tumor affecting a greater part of the sacrum. Tumor resection was performed in the first act out off retroperitoneal organs (colon and blood vessels), sacroiliac joints were open by the ventral side, the L5 discus removed, the S2-S5 roots cut off. In the second act, performed three weeks later, sacrectomy was completed by the reconstruction of pelvic ring and spinal-pelvic fixation. Then, the standard technique was modified to provide additional spinal fixation. The results of the operation (duration, blood loss, postoperative deficit) were quite comparable with, and in some aspects even better than the results published in the literature. Total sacrectomy with spinal-pelvic fixation can be a therapy of choice in patients with extensive sacral tumors requaring, however, the multidisciplinary approach and a considerable experience with instrumental spinal stabilization.

  2. 21 CFR 888.3050 - Spinal interlaminal fixation orthosis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Spinal interlaminal fixation orthosis. 888.3050 Section 888.3050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3050 Spinal interlaminal fixation...

  3. 21 CFR 888.3050 - Spinal interlaminal fixation orthosis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Spinal interlaminal fixation orthosis. 888.3050 Section 888.3050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3050 Spinal interlaminal fixation...

  4. 21 CFR 888.3050 - Spinal interlaminal fixation orthosis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Spinal interlaminal fixation orthosis. 888.3050 Section 888.3050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3050 Spinal interlaminal fixation...

  5. Surgical Intervention for Instability of the Craniovertebral Junction

    PubMed Central

    TAKAYASU, Masakazu; AOYAMA, Masahiro; JOKO, Masahiro; TAKEUCHI, Mikinobu

    2016-01-01

    Surgical approaches for stabilizing the craniovertebral junction (CVJ) are classified as either anterior or posterior approaches. Among the anterior approaches, the established method is anterior odontoid screw fixation. Posterior approaches are classified as either atlanto-axial fixation or occipito-cervical (O-C) fixation. Spinal instrumentation using anchor screws and rods has become a popular method for posterior cervical fixation. Because this method achieves greater stability and higher success rates for fusion without the risk of sublaminar wiring, it has become a substitute for previous methods that used bone grafting and wiring. Several types of anchor screws are available, including C1/2 transarticular, C1 lateral mass, C2 pedicle, and translaminar screws. Appropriate anchor screws should be selected according to characteristics such as technical feasibility, safety, and strength. With these stronger anchor screws, shorter fixation has become possible. The present review discusses the current status of surgical interventions for stabilizing the CVJ. PMID:27041630

  6. [Development and current situation of reconstruction methods following total sacrectomy].

    PubMed

    Huang, Siyi; Ji, Tao; Guo, Wei

    2018-05-01

    To review the development of the reconstruction methods following total sacrectomy, and to provide reference for finding a better reconstruction method following total sacrectomy. The case reports and biomechanical and finite element studies of reconstruction following total sacrectomy at home and abroad were searched. Development and current situation were summarized. After developing for nearly 30 years, great progress has been made in the reconstruction concept and fixation techniques. The fixation methods can be summarized as the following three strategies: spinopelvic fixation (SPF), posterior pelvic ring fixation (PPRF), and anterior spinal column fixation (ASCF). SPF has undergone technical progress from intrapelvic rod and hook constructs to pedicle and iliac screw-rod systems. PPRF and ASCF could improve the stability of the reconstruction system. Reconstruction following total sacrectomy remains a challenge. Reconstruction combining SPF, PPRF, and ASCF is the developmental direction to achieve mechanical stability. How to gain biological fixation to improve the long-term stability is an urgent problem to be solved.

  7. Repeated posterior dislocation of total hip arthroplasty after spinal corrective long fusion with pelvic fixation.

    PubMed

    Furuhashi, Hiroki; Togawa, Daisuke; Koyama, Hiroshi; Hoshino, Hironobu; Yasuda, Tatsuya; Matsuyama, Yukihiro

    2017-05-01

    Several reports have indicated that anterior dislocation of total hip arthroplasty (THA) can be caused by spinal degenerative changes with excessive pelvic retroversion. However, no reports have indicated that posterior dislocation can be caused by fixed pelvic anteversion after corrective spine surgery. We describe a rare case experiencing repeated posterior THA dislocation that occurred at 5 months after corrective spinal long fusion with pelvic fixation. A 64-year-old woman had undergone bilateral THA at 13 years before presenting to our institution. She had been diagnosed with kyphoscoliosis and underwent three subsequent spinal surgeries after the THA. We finally performed spinal corrective long fusion from T5 to ilium with pelvic fixation (with iliac screws). Five months later, she experienced severe hip pain when she tried to stand up from the toilet, and was unable to move, due to posterior THA dislocation. Therefore, we performed closed reduction under sedation, and her left hip was easily reduced. After the reduction, she started to walk with a hip abduction brace. However, she had experienced 5 subsequent dislocations. Based on our findings and previous reports, we have hypothesized that posterior dislocation could be occurred after spinal corrective long fusion with pelvic fixation due to three mechanisms: (1) a change in the THA cup alignment before and after spinal corrective long fusion surgery, (2) decreased and fixed pelvic posterior tilt in the sitting position, or (3) the trunk's forward tilting during standing-up motion after spinopelvic fixation. Spinal long fusion with pelvic fixation could be a risk factor for posterior THA dislocation.

  8. 21 CFR 888.3060 - Spinal intervertebral body fixation orthosis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Spinal intervertebral body fixation orthosis. 888.3060 Section 888.3060 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3060 Spinal intervertebral...

  9. 21 CFR 888.3060 - Spinal intervertebral body fixation orthosis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Spinal intervertebral body fixation orthosis. 888.3060 Section 888.3060 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3060 Spinal intervertebral...

  10. 21 CFR 888.3060 - Spinal intervertebral body fixation orthosis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Spinal intervertebral body fixation orthosis. 888.3060 Section 888.3060 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3060 Spinal intervertebral...

  11. Significance of fixation of the vertebral column for spinal cord injury experiments.

    PubMed

    Liu, Fei; Luo, Zhuo-Jin; You, Si-Wei; Jiao, Xi-Ying; Meng, Xiao-Mei; Shi, Ming; Wang, Chun-Ting; Ju, Gong

    2003-08-01

    Thoracic spinal cord transections were performed in adult rats. The animals were divided into two groups, with or without internal fixation of the involved vertebral column. Histologic and immunohistochemical studies were performed to compare the effect of internal fixation of the vertebral column. To find out the aspects and extent of beneficial effects of vertebral column fixation for spinal cord repair. Vertebral column fixation is a routine procedure in clinical spinal cord surgery. Paradoxically, most, if not all, animal spinal cord experiments seem to have ignored the importance of vertebral column fixation. During trunk movements, the vertebral column flexes to different directions, accompanied by bending of the spinal cord. Following spinal cord lesions, with frequent bending of the cord there will be repeated bleeding, inflammation, and other pathologic processes at the lesion site. Thus, the healing process will be hampered. The severity of the damages that will be brought about by bending of the cord is, to a certain degree, unpredictable. There will be rather big individual variations in injury and repair among the same type of experiments, rendering quantification and conclusion difficult. Adult Sprague-Dawley rats were used. The thoracic spinal cord was transected. Strong stainless steel wires were used for internal fixation of the vertebral column. The histology of the horizontal sections of the spinal cord segment, which included the lesion site, was examined at the 14th postoperative day. The volumes of the secondary degeneration and meningeal scar, the gap between the borders of the proximal and distal stumps of the transected spinal cord, the thickness of the meningeal scar, the astrocytic reaction, and the abundance of regenerating nerve fibers at the lesion site were compared between the vertebral column fixed and nonfixed groups. Whenever possible, the results were evaluated quantitatively. In all these aspects, the internally fixed group was consistently far better than the unfixed group. The quantitative analyses were as follows (fixed/unfixed): 1)volume of secondary degeneration: 1.07 +/- 0.20/1.81 +/- 0.43 mm3 (P < 0.01); 2) volume of meningeal scar: 2.38 +/- 0.55/4.34 +/- 1.40 mm3 (P < 0.05); 3) distance between cord stumps: 1.38 +/- 0.34/2.35 +/- 0.79 mm (P < 0.05); 4) the mean thinnest dimension of the meningeal scar: 0.90 +/- 0.43/1.98 +/- 0.85 mm (P < 0.05). Vertebral column fixation is a crucial procedure for spinal cord animal experiments.

  12. Expert's comment concerning Grand Rounds case entitled "Closing-opening wedge osteotomy for severe, rigid thoraco-lumbar post-tubercular kyphosis" (by S. Rajasekaran, P. Rishimugesh Kanna and Ajoy Prasad Shetty).

    PubMed

    Luk, Keith D K

    2011-03-01

    Prevention or correction of severe kyphotic deformity in addition to eradication of the infective focus has become the modern standard of management of tuberculosis of the spine. Circumferential excision of the kyphus is now technically feasible with the development of rigid pedicle screw fixation system and intraoperative spinal cord monitoring in the past two decades.

  13. Pedicle screw fixation in spinal disorders: a European view.

    PubMed

    Boos, N; Webb, J K

    1997-01-01

    Continuing controversy over the use of pedicular fixation in the United States is promoted by the lack of governmental approval for the marketing of these devices due to safety and efficacy concerns. These implants have meanwhile become an invaluable part of spinal instrumentation in Europe. With regard to the North American view, there is a lack of comprehensive reviews that consider the historical evolution of pedicle screw systems, the rationales for their application, and the clinical outcome from a European perspective. This literature review suggests that pedicular fixation is a relatively safe procedure and is not associated with a significantly higher complication risk than non-pedicular instrumentation. Pedicle screw fixation provides short, rigid segmental stabilization that allows preservation of motion segments and stabilization of the spine in the absence of intact posterior elements, which is not possible with non-pedicular instrumentation. Fusion rates and clinical outcome in the treatment of thoracolumbar fractures appear to be superior to that achieved using other forms of treatment. For the correction of spinal deformity (i.e., scoliosis, kyphosis, spondylolisthesis, tumor), pedicular fixation provides the theoretical benefit of rigid segmental fixation and of facilitated deformity correction by a posterior approach, but the clinical relevance so far remains unknown. In low-back pain disorders, a literature analysis of 5,600 cases of lumbar fusion with different techniques reveals a trend that pedicle screw fixation enhances the fusion rate but not clinical outcome. The most striking finding in the literature is the large range in the radiological and clinical results. For every single fusion technique poor and excellent results have been described. This review argues that European spine surgeons should begin to back up the evident benefits of pedicle screw systems for specific spinal disorders by controlled prospective clinical trials. This may prevent forthcoming medical licensing authorities from restricting the use of pedicle screw devices and dictating the practice of spinal surgery in Europe in the near future.

  14. Migration of luque rods through a laminectomy defect causing spinal cord compression.

    PubMed

    Quint, D J; Salton, G

    1993-01-01

    Internal fixation of traumatic spinal injuries has been associated with spinal canal stenosis, spinal cord compression, and nerve root impingement. We present a case of spinal cord/cauda equina compression due to migration of intact, anchored thoracolumbar Luque rods into the spinal canal through a laminectomy defect, leading to neurologic complications 10 years after the original operation.

  15. Combined spinal epidural anesthesia in achondroplastic dwarf for femur surgery

    PubMed Central

    Bakhshi, Rochana Girish; Jagtap, Sheetal R.

    2011-01-01

    Achondroplasia is the commonest form of short-limbed dwarfism and occurs in 1:26,000-40,000 live births. This is an autosomal dominant disorder with abnormal endochondral ossification whereas periosteal and intramembranous ossification are normal. The basic abnormality is a disturbance of cartilage formation mainly at the epiphyseal growth plates and at the base of the skull. The anesthetic management of achondroplastic dwarfs is a challenge to the anesthesiologist. Both regional as well as general anesthesia have their individual risks and consequences. We report a case of an achondroplastic dwarf in whom combined spinal epidural anesthesia was used for fixation of a fractured femur. The patient had undergone previous femur surgery under general anesthesia since he had been informed that spinal anesthesia could be very problematic. There was no technical difficulty encountered during the procedure and an adequate level was achieved with low-dose local anesthetics without any problem. Postoperative pain relief was offered for three consecutive postoperative days using epidural tramadol. We discuss the anesthetic issues and highlight the role of combined spinal epidural anesthesia with low-dose local anesthetics in this patient. This approach also helped in early ambulation and postoperative pain relief. PMID:24765361

  16. Treatment of Spinal Tuberculosis by Debridement, Interbody Fusion and Internal Fixation via Posterior Approach Only.

    PubMed

    Tang, Ming-xing; Zhang, Hong-qi; Wang, Yu-xiang; Guo, Chao-feng; Liu, Jin-yang

    2016-02-01

    Surgical treatment for spinal tuberculosis includes focal tuberculosis debridement, segmental stability reconstruction, neural decompression and kyphotic deformity correction. For the lesions mainly involved anterior and middle column of the spine, anterior operation of debridement and fusion with internal fixation has been becoming the most frequently used surgical technique for the spinal tuberculosis. However, high risk of structural damage might relate with anterior surgery, such as damage in lungs, heart, kidney, ureter and bowel, and the deformity correction is also limited. Due to the organs are in the front of spine, there are less complications in posterior approach. Spinal pedicle screw passes through the spinal three-column structure, which provides more powerful orthopedic forces compared with the vertebral body screw, and the kyphotic deformity correction effect is better in posterior approach. In this paper, we report a 68-year-old male patient with thoracic tuberculosis who underwent surgical treatment by debridement, interbody fusion and internal fixation via posterior approach only. The patient was placed in prone position under general anesthesia. Posterior midline incision was performed, and the posterior spinal construction was exposed. Then place pedicle screw, and fix one side rod temporarily. Make the side of more bone destruction and larger abscess as lesion debridement side. Resect the unilateral facet joint, and retain contralateral structure integrity. Protect the spinal cord, nerve root. Clear sequestrum, necrotic tissue, abscess of paravertebral and intervertebral space. Specially designed titanium mesh cages or bone blocks were implanted into interbody. Fix both side rods and compress both sides to make the mesh cages and bone blocks tight. Reconstruct posterior column structure with allogeneic bone and autologous bone. Using this technique, the procedures of debridement, spinal cord decompression, deformity correction, bone grafting, and internal fixation can be completed with only one incision and surgical position, and the deformity correction efficiency is higher than anterior surgery. © 2016 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  17. Migration of titanium cable into spinal cord and spontaneous C2 and C3 fusion: Case report of possible causes of fatigue failure after posterior atlantoaxial fixation.

    PubMed

    Li, Huibo; Lou, Jigang; Liu, Hao

    2016-12-01

    Atlantoaxial instability is a common and serious injury of the upper cervical spine. Brooks' procedure is widely used to reconstruct the unstable atlantoaxial joint. The migration into spinal cord of titanium cable and spontaneous fusion between C2 and C3 has been little reported and the management of such a patient is difficult. We describe an unusual case of fatigue failure of posterior titanium atlantoaxial cable fixation with migration into the spinal cord and spontaneous fusion between C2 and C3. A 16-year-old girl complained of cervico-occipital pain with numbness and weakness of extremities 3 months ago. The girl underwent posterior C1-C2 arthrodesis with titanium cables and autogenous iliac crest bone grafting when she was 6 years old. When presented to our emergency department, imaging revealed the cracked titanium atlantoaxial cable and the spontaneous fusion between C2 and C3. Computed tomography demonstrated a broken wire with anterior migration of the cable into the spinal cord. The patient underwent posterior approach cervical spinal surgery to remove the broken cables. She remains neurologically intact a year following the posterior approach cervical spine surgery. Brooks' posterior stabilization could not effectively control rotation at the atlantoaxial articulation, so surgeons must be aware of the potential of fatigue failure of cables as well as the possibility of its migration into the spinal cord when using Brooks' posterior stabilization. Bilateral C1 lateral mass and C2 pedicle screw fixation or transarticular screw fixation are recommended by the authors in the event of rotatory instability.

  18. A biomechanical analysis of the self-retaining pedicle hook device in posterior spinal fixation

    PubMed Central

    van Laar, Wilbert; Meester, Rinse J.; Smit, Theo H.

    2007-01-01

    Regular hooks lack initial fixation to the spine during spinal deformity surgery. This runs the risk of posterior hook dislodgement during manipulation and correction of the spinal deformity, that may lead to loss of correction, hook migration, and post-operative junctional kyphosis. To prevent hook dislodgement during surgery, a self-retaining pedicle hook device (SPHD) is available that is made up of two counter-positioned hooks forming a monoblock posterior claw device. The initial segmental posterior fixation strength of a SPHD, however, is unknown. A biomechanical pull-out study of posterior segmental spinal fixation in a cadaver vertebral model was designed to investigate the axial pull-out strength for a SPHD, and compared to the pull-out strength of a pedicle screw. Ten porcine lumbar vertebral bodies were instrumented in pairs with two different instrumentation constructs after measuring the bone mineral density of each individual vertebra. The instrumentation constructs were extracted employing a material testing system using axial forces. The maximum pull-out forces were recorded at the time of the construct failure. Failure of the SPHD appeared in rotation and lateral displacement, without fracturing of the posterior structures. The average pull-out strength of the SPHD was 236 N versus 1,047 N in the pedicle screws (P < 0.001). The pull-out strength of the pedicle screws showed greater correlation with the BMC compared to the SPHD (P < 0.005). The SPHD showed to provide a significant inferior segmental fixation to the posterior spine in comparison to pedicle screw fixation. Despite the beneficial characteristics of the monoblock claw construct in a SPHD, that decreases the risk of posterior hook dislodgement during surgery compared to regular hooks, the SPHD does not improve the pull-out strength in such a way that it may provide a biomechanically solid alternative to pedicle screw fixation in the posterior spine. PMID:17203270

  19. Braided tubular superelastic cables provide improved spinal stability compared to multifilament sublaminar cables.

    PubMed

    Tremblay, Jaëlle; Mac-Thiong, Jean-Marc; Brailovski, Vladimir; Petit, Yvan

    2015-09-01

    This study investigates the use of braided tubular superelastic cables, previously used for sternum closure following sternotomy, as sublaminar fixation method. It compares the biomechanical performance of spinal instrumentation fixation systems with regular sublaminar cables and proprietary superelastic cables. A hybrid experimental protocol was applied to six porcine L1-L4 spinal segments to compare multifilament sublaminar cables (Atlas, Medtronic Sofamor Danek, Memphis, TN) with proprietary superelastic cables. First, intact total range of motion was determined for all specimens using pure moment loading. Second, pure moments were imposed to the instrumented specimens until these intact total ranges of motion were reproduced. Compared to the intact specimens, the use of superelastic cables resulted in stiffer instrumented specimens than the use of multifilament cables for all the loading modes except axial torsion. Consequently, the superelastic cables limited the instrumented segments mobility more than the multifilament cables. Spinal instrumentation fixation systems using superelastic cables could be a good alternative to conventional sublaminar cables as it maintains a constant stabilization of the spine during loading. © IMechE 2015.

  20. Surgical treatment for old subaxial cervical dislocation with bilateral locked facets in a 3-year-old girl: A case report.

    PubMed

    Li, Cheng; Li, Lei; Duan, Jingzhu; Zhang, Lijun; Liu, Zhenjiang

    2018-05-01

    This study aimed to describe the case of a 3-year-old girl with old bilateral facet dislocation on cervical vertebrae 6 and 7, who had spinal cord transection, received surgical treatment, and achieved a relative satisfactory therapeutic effect. A 3-year-old girl was urgently transferred to the hospital after a car accident. DIAGNOSES:: she was diagnosed with splenic rupture, intracranial hemorrhage, cervical dislocation, spinal transection, and Monteggia fracture of the left upper limb. The girl underwent emergency splenectomy and was transferred to the intensive care unit of the hospital 15 days later. One-stage anterior-posterior approach surgery (anterior discectomy, posterior laminectomy, and pedicle screw fixation) was performed when the patient stabilized after 45-day symptomatic treatment. The operation was uneventful. The reduction of lower cervical dislocation was satisfactory, with sufficient spinal cord decompression. The internal fixation position was good, and the spinal sequence was well restored. The girl was discharged 2 weeks later after the operation and followed up for 2 years. The major nerve function of both upper limbs was recovered, with no obvious retardation of the growth of immature spine. A satisfactory therapeutic effect was achieved for a pediatric old subaxial cervical dislocation with bilateral locked facets using anterior discectomy, posterior laminectomy, and pedicle screw fixation. The posterior pedicle screw fixation provided a good three-dimensional stability of the spine, with reduced risk and complications caused by anterior internal fixation. The growth of immature spine was not obviously affected during the 2-year follow-up.

  1. Hybrid fixation with sublaminar polyester bands in the treatment of neuromuscular scoliosis: a comparative analysis.

    PubMed

    Albert, Michael C; LaFleur, Brett C

    2015-03-01

    Segmental spinal instrumentation with Luque wire fixation has been the standard treatment of neuromuscular scoliosis for >30 years. More recently, pedicle screw constructs have become the most widely utilized method of posterior spinal fixation; however, they are associated with complications such as implant malposition. We report the use of polyester bands and clamps utilized with pedicle screws in a hybrid fixation construct in the treatment of neuromuscular scoliosis. A retrospective review was conducted of 115 pediatric spinal deformity cases between 2008 and 2010 at a single center performed by a single surgeon. Intraoperative and postoperative complications were recorded. Radiographs were reviewed preoperatively and at the latest follow-up. A systematic review of the literature was conducted. Data from case series reporting outcomes of sublaminar wires and all-pedicle screw constructs in the treatment of neuromuscular scoliosis were compared with outcomes of the present study. Twenty-nine patients with neuromuscular scoliosis who underwent segmental spinal instrumentation with a hybrid construct including sublaminar bands and pedicle screws were included. There was an average follow-up of 29 months (range, 12 to 40 mo). The average postoperative correction of coronal balance was 69% (range, 24 to 71 degrees). Sagittal balance was corrected to within 2 cm of the C7 plumbline in 97% of patients. The loss of coronal and sagittal correction at latest follow-up was 0% and 2%, respectively. There were 2 intraoperative clamp failures of the 398 implants (0.5%). There were 2 major (6.9%) and 7 minor (24%) complications in 7 patients (24% overall). These results compared favorably to previous case series of sublaminar wire and all-pedicle screw fixation techniques. The polyester band technique is an excellent adjunct in the correction of spinal deformity in patients with neuromuscular scoliosis. Sublaminar bands utilized in a hybrid construct appear to be safe, can achieve corrections equivalent to all-pedicle screw constructs, and may decrease the potential complications associated with every level transpedicular fixation in the patient with a highly dysmorphic and osteoporotic spine. Level IV: cohort study.

  2. Anterior Spinal Reconstruction to the Clivus Using an Expandable Cage After C2 Chordoma Resection Via a Labiomandibular Glossotomy Approach: A Technical Report.

    PubMed

    Ozpinar, Alp; Liu, Jesse J; Whitney, Nathaniel L; Tempel, Zachary J; Choi, Philip A; Andersen, Peter E; Coppa, Nicholas D; Hamilton, D Kojo

    2016-06-01

    En bloc resection of high-cervical chordomas is a technically challenging procedure associated with significant morbidity. Two key components of this procedure include the approach and the method of spinal reconstruction. A limited number of reported cases of en bloc resection of high-cervical chordomas have been reported in the literature. We report a novel case using an expandable cage to reconstruct the anterior spinal column above C2 with fixation to the clivus. We also report a novel anterior approach to the high-cervical spine via a midline labiomandibular glossotomy. We detail the management of complications related to 2 instances of wound dehiscence and hardware exposure requiring two additional operations. The final surgical procedure involved explantation of the anterior cervical plate and use of a vascularized radial graft to close the posterior pharyngeal defect and protect the hardware. At 26-month follow-up, the patient remained disease free without any neurologic deficit. We report the novel use of the midline labiomandibular glossotomy for surgical approach and reconstruction of the anterior column to the clivus with an expandable cage. The unique features of this operative strategy allowed the surgical team to tailor the construct intraoperatively, resulting in solid arthrodesis without significant neurologic sequelae. Labiomandibular glossotomy for approach to high anterior cervical chordomas followed by craniospinal reconstruction to the clivus with an expandable cage represents a novel technique for managing high cervical chordomas. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. A case report of spondylectomy with circumference reconstruction for aggressive vertebral hemangioma covering the whole cervical spine (C4) with progressive spinal disorder.

    PubMed

    Nakahara, Masayuki; Nishida, Kenki; Kumamoto, Shinji; Hijikata, Yasukazu; Harada, Kei

    2017-05-01

    To describe the surgical experience of spondylectomy and spinal reconstruction for aggressive vertebral hemangioma (VH) induced at the C4 vertebra. No reports have described surgical strategy in cases covering an entire cervical vertebra presenting with progressive myelopathy. A 28-year-old man presented with rapidly progressing skilled motor dysfunction and gait disorder. The Japanese Orthopedic Association (JOA) score was 6. Radiography showed a honeycomb appearance for the entire circumference of the C4 vertebra. Spinal computed tomography and magnetic resonance imaging showed vertebral tumor with extraosseous extension causing spinal cord compression. Results of diagnostic imaging were strongly suggestive of VH. Transarterial embolization of the spinal body branch was performed first to decrease intraoperative bleeding, followed by cervical posterior fixation to stabilize the unstable segment and excision biopsy to obtain a definitive diagnosis. After definitive diagnosis of cavernous hemangioma, two-stage surgery (anterior and posterior) was performed to complete total spondylectomy and 360° spinal reconstruction. Despite multiple operations, JOA scores were 8.5 after posterior fixation, 10.5 after anterior surgery, 11 after final surgery and 16 on postoperative day 90. The patient acquired excellent clinical results without complications and returned to society. The present three-stage surgery comprising fixation, biopsy, and final spondylectomy with circumferential fusion from anterior and posterior approaches may offer a useful choice for aggressive VH covering the entire cervical spine with rapidly progressive myelopathy.

  4. Percutaneous Instrumentation of a Complex Lumbar Spine Fracture with Bilateral Pedicle Dissociation: Case Report and Technical Note.

    PubMed

    Luther, Evan; Urakov, Timur; Vanni, Steven

    2018-06-11

     Complex traumatic lumbar spine fractures are difficult to manage and typically occur in younger patients. Surgical immobilization for unstable fractures is an accepted treatment but can lead to future adjacent-level disease. Furthermore, large variations in fracture morphology create significant difficulties when attempting fixation. Therefore, a surgical approach that considers both long-term outcomes and fracture type is of utmost importance. We present a novel technique for percutaneous fixation without interbody or posterolateral fusion in a young patient with bilateral pedicle dissociations and an acute-onset incomplete neurologic deficit.  A 20-year-old man involved in a motorcycle accident presented with unilateral right lower extremity paresis and sensory loss with intact rectal tone and no saddle anesthesia. Lumbar computed tomography (CT) demonstrated L2 and L3 fractures associated with bilateral pedicle dislocations. Lumbar magnetic resonance imaging showed draping of the conus medullaris/cauda equina anteriorly over the kyphotic deformity at L2 with minimal associated canal stenosis at L2 and L3. He was treated with emergent percutaneous fixation of the fracture segment without interbody or posterolateral fusion. Decompression was not performed because of the negligible amount of canal stenosis and high likelihood of cerebrospinal fluid leakage due to dural tears from the fractures. Surgical fixation of the L2 vertebra was achieved by cannulating the left pedicle with an oversized tap while holding the right pedicle in place with a normal tap and then driving screws into the left and right pedicles, respectively, thus reducing the free-floating fracture segment. At 18 months after surgery, a follow-up CT demonstrated good cortication across the prior pedicle fractures, and the instrumentation was removed without any obvious signs of instability or disruption of the alignment at the thoracolumbar junction.  We present a novel technique for percutaneous reduction and fixation of bilateral pedicle fractures with significant dissociation from the vertebral body, associated neural compression from the kyphotic deformity, and minimal spinal canal stenosis. Furthermore, we argue that early fixation and reduction of the fracture prevented irreversible neurologic compromise, and the absence of interbody or posterolateral fusion ultimately preserved the spinal mobility of the patient once the hardware was removed. Georg Thieme Verlag KG Stuttgart · New York.

  5. Posterior-only approach for lumbar vertebral column resection and expandable cage reconstruction for spinal metastases.

    PubMed

    Jandial, Rahul; Kelly, Brandon; Chen, Mike Yue

    2013-07-01

    The increasing incidence of spinal metastasis, a result of improved systemic therapies for cancer, has spurred a search for an alternative method for the surgical treatment of lumbar metastases. The authors report a single-stage posterior-only approach for resecting any pathological lumbar vertebral segment and reconstructing with a medium to large expandable cage while preserving all neurological structures. The authors conducted a retrospective consecutive case review of 11 patients (5 women, 6 men) with spinal metastases treated at 1 institution with single-stage posterior-only vertebral column resection and reconstruction with an expandable cage and pedicle screw fixation. For all patients, the indications for operative intervention were spinal cord compression, cauda equina compression, and/or spinal instability. Neurological status was classified according to the American Spinal Injury Association impairment scale, and functional outcomes were analyzed by using a visual analog scale for pain. For all patients, a circumferential vertebral column resection was achieved, and full decompression was performed with a posterior-only approach. Each cage was augmented by posterior pedicle screw fixation extending 2 levels above and below the resected level. No patient required a separate anterior procedure. Average estimated blood loss and duration of each surgery were 1618 ml (range 900-4000 ml) and 6.6 hours (range 4.5-9 hours), respectively. The mean follow-up time was 14 months (range 10-24 months). The median survival time after surgery was 17.7 months. Delayed hardware failure occurred for 1 patient. Preoperatively, 2 patients had intractable pain with intact lower-extremity strength and 8 patients had severe intractable pain, lower-extremity paresis, and were unable to walk; 4 of whom regained the ability to walk after surgery. Two patients who were paraplegic before decompression recovered substantial function but remained wheelchair bound, and 2 patients remained paraparetic after the surgery. No patients had lasting intraoperative neuromonitoring changes, and none died. Complications included 2 reoperations, 1 delayed hardware failure (cage subsidence that did not require revision), and 3 incidental durotomies (none of which required reoperation). No postoperative pneumonia, ileus, or deep venous thrombosis developed in any patient. A posterior-only approach for vertebral segment resection with preservation of spinal nerve roots is a viable technique that can be used throughout the entire lumbar spine. Extensive mobilization of the nerve roots is of utmost importance and allows for insertion and expansion of medium-sized, in situ expandable cages in the midline. This approach, although technically challenging, might reduce the morbidity associated with an anterior approach.

  6. Spinal fusion-hardware construct: Basic concepts and imaging review

    PubMed Central

    Nouh, Mohamed Ragab

    2012-01-01

    The interpretation of spinal images fixed with metallic hardware forms an increasing bulk of daily practice in a busy imaging department. Radiologists are required to be familiar with the instrumentation and operative options used in spinal fixation and fusion procedures, especially in his or her institute. This is critical in evaluating the position of implants and potential complications associated with the operative approaches and spinal fixation devices used. Thus, the radiologist can play an important role in patient care and outcome. This review outlines the advantages and disadvantages of commonly used imaging methods and reports on the best yield for each modality and how to overcome the problematic issues associated with the presence of metallic hardware during imaging. Baseline radiographs are essential as they are the baseline point for evaluation of future studies should patients develop symptoms suggesting possible complications. They may justify further imaging workup with computed tomography, magnetic resonance and/or nuclear medicine studies as the evaluation of a patient with a spinal implant involves a multi-modality approach. This review describes imaging features of potential complications associated with spinal fusion surgery as well as the instrumentation used. This basic knowledge aims to help radiologists approach everyday practice in clinical imaging. PMID:22761979

  7. Rigid fixation improves outcomes of spinal fusion for C1-C2 instability in children with skeletal dysplasias.

    PubMed

    Helenius, Ilkka; Crawford, Haemish; Sponseller, Paul D; Odent, Thierry; Bernstein, Robert M; Stans, Anthony A; Hedequist, Daniel; Phillips, Jonathan H

    2015-02-04

    Upper cervical instability is common in many skeletal dysplasias, and surgical treatment can be difficult because of small, fragile osseous elements. In this study of children with skeletal dysplasia and upper cervical instability, we compared fusion rates and complications between (1) patients treated with no instrumentation or with wiring techniques and (2) those who underwent rigid cervical spine instrumentation. We also sought to characterize the presentation and common parameters of upper cervical instability in this population. A multicenter study identified twenty-eight children with skeletal dysplasia who underwent surgery from 2000 through 2011 for C1-C2 instability and were followed for a minimum of two years. Fourteen children were treated with no instrumentation or with instrumentation with wires or cables (nonrigid-fixation group) and fourteen were treated with screws (or hooks) and rods (rigid-fixation group). All patients received autograft, and twenty (twelve in the nonrigid group and eight in the rigid group) were treated with a halo-body jacket. Fourteen children had C1-C2 fusion, and fourteen had occipitocervical fusion. Eleven (39%) underwent spinal cord decompression. The nonunion rate was significantly higher in the nonrigid-fixation group (six of fourteen) than in the rigid-fixation group (zero of fourteen; p = 0.0057). Complications, including nonunion, occurred in nine patients in the nonrigid group and one patient in the rigid group. However, two of the complications in the nonrigid-fixation group were vertebral artery bleeding episodes that actually occurred during an attempt at rigid fixation (the fixation was subsequently done with wiring). No new neurologic deficits were observed. Five of the seven children with a preoperative neurologic deficit showed at least partial recovery, with significant improvement in the Japanese Orthopaedic Association upper-extremity score (p = 0.047). The nonunion rate is relatively high after patients undergo spinal fusion for C1-C2 instability with nonrigid instrumentation, even if a halo-body jacket is applied. Rigid fixation with screws and rods improves fusion rates. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  8. Improved vacuum sealing drainage for treatment of surgical site infection following posterior spinal internal fixation

    PubMed Central

    Zhang, Hengyan; Li, Qiyi

    2018-01-01

    Abstract Rationale: Surgical site infection (SSI) following spine surgeries involving internal fixation often require removing the instrument; however, this can cause spinal instability. Previous reports have demonstrated the usefulness of vacuum sealing drainage (VSD) therapy, but the cases require wound opening, aseptic condition to replace the VSD device, and a secondary operation to close the wound. Thus, to improve the VSD treatment and develop a maneuverable procedure, make sense in spine surgery. Patients concerns: A 59-year-old male patient with a T12 vertebral fracture was affected by SSIs after spinal osteotomy with internal fixation. Diagnoses: The patient complained of wound exudation and had a fever 3 weeks after posterior spinal surgery. Initial serum investigations showed elevated white blood cell count and bacterial cultures of wound exudate were positive for Enterococcus faecalis. Therefore, SSI is confirmed. Interventions: The infection was not controlled after 2 debridements, so the patient was treated with VSD treatment. The VSD foam dressings containing a drainage tube were placed into the wound from the exudation site of the wound until they contacted the internal fixation devices. After covering external fixation devices, continuous drainage was performed for 24 h. The VSD device was replaced every 4 to 5 days until the wound effusion stopped. All of the operations were performed at the bedside without complex manipulation or secondary closure under harsh aseptic condition. Outcomes: Wound exudation decreased remarkably and the infection was controlled 2 weeks after the application of VSD treatment. After 5 weeks, inflammatory indicators all decreased to normal levels and the exudate of the wound had stopped. The VSD treatment was then terminated and the drainage site of the wound was sutured. After 7 weeks, complete wound healing was achieved and no infection recurred during the 6-month follow-up. Lessons: VSD could be a reliable treatment for SSIs that require preservation of internal fixation. Complete opening of the wound during the VSD treatment and secondary wound closure surgery were avoided. PMID:29443786

  9. Finite element analysis and cadaveric cinematic analysis of fixation options for anteriorly implanted trabecular metal interbody cages.

    PubMed

    Berjano, Pedro; Blanco, Juan Francisco; Rendon, Diego; Villafañe, Jorge Hugo; Pescador, David; Atienza, Carlos Manuel

    2015-11-01

    To assess, with finite element analysis and an in vitro biomechanical study in cadaver, whether the implementation of an anterior interbody cage made of hedrocel with nitinol shape memory staples in compression increases the stiffness of the stand-alone interbody cage and to compare these constructs' stiffness to other constructs common in clinical practice. A biomechanical study with a finite element analysis and cadaveric testing assessed the stiffness of different fixation modes for the L4-L5 functional spinal unit: intact spine, destabilized spine with discectomy, posterior pedicle-screw fixation, anterior stand-alone interbody cage, anterior interbody cage with bilateral pedicle screws and anterior interbody cage with two shape memory staples in compression. These modalities of vertebral fixation were compared in four loading modes (flexion, extension, lateral bending, and axial rotation). The L4-L5 spinal unit with an anterior interbody cage and two staples was stiffer than the stand-alone cage. The construct stiffness was similar to that of a model of posterior pedicular stabilization. The stiffness was lower than that of the anterior cage plus bilateral pedicle-screw fixation. The use of an anterior interbody implant with shape memory staples in compression may be an alternative to isolated posterior fixation and to anterior isolated implants, with increased stiffness.

  10. Image Guidance to Aid Pedicle Screw Fixation of a Lumbar Fracture-Dislocation Injury in a Toddler.

    PubMed

    Houten, John K; Nahkla, Jonathan; Ghandi, Shashank

    2017-09-01

    Pedicle screw fixation of the lumbar spine in children age <2 years is particularly challenging, as successful cannulation of the small pedicle dimensions requires a high level of precision and there are no implants specifically designed for the infant spine. Image-guided navigation is commonly used in adult spinal surgery and may be particularly helpful for the placement of spinal screws in areas where the bony anatomy is small and/or anatomically complex, as in the upper cervical area. A 19-month-old female presented with a fracture-dislocation injury of L1-2. Intraoperative imaging using the O-arm multidimensional imaging system was networked to a workstation, and neuronavigation was used to place pedicle instrumentation with 3.5-mm-diameter polyaxial screws designed for posterior cervical fixation. At a 48-month follow-up, the patient was neurologically intact, demonstrated normal physical development, and was engaging in normal physical activity for her age. Radiographs obtained approximately 4 years postsurgery showed no evidence of loss for fixation. Image-guided placement of pedicle screws may be a useful aid in achieving accurate and safe fixation in the small dimensions of the infant spine. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. [Clinical application of atlas translaminar screws fixation in treatment of atlatoaxial instability].

    PubMed

    Wang, Guoyou; Fu, Shijie; Shen, Huarui; Guan, Taiyuan; Xu, Ping

    2013-10-01

    To explore the effectiveness of fixation of atlas translaminar screws in the treatment of atlatoaxial instability. A retrospective analysis was made on the clinical data of 32 patients with atlatoaxial instability treated with atlantoaxial trans-pedicle screws between March 2007 and August 2009. Of them, 7 patients underwent atlas translaminar screws combined with axis transpedicle screws fixation because of fracture types, anatomic variation, and intraoperative reason, including 5 males and 2 females with an average age of 48.2 years (range, 35-69 years). A total of 9 translaminar screws were inserted. Injury was caused by traffic accident in 4 cases, falling from height in 2 cases, and crushing in 1 case. Two cases had simple odontoid fracture (Anderson type II), and 5 cases had odontoid fracture combined with other injuries (massa lateralis atlantis fracture in 2, atlantoaxial dislocation in 1, and Hangman fracture in 2). The interval between injury and operation was 4-9 days (mean, 6 days). The preoperative Japanese Orthopaedic Association (JOA) score was 8.29 +/- 1.60. The X-ray films showed good position of the screws. Healing of incision by first intention was obtained, and no patient had injuries of the spinal cord injury, nerve root, and vertebral artery. Seven cases were followed up 9-26 months (mean, 14 months). Good bone fusion was observed at 8 months on average (range, 6-11 months). No loosening, displacement, and breakage of internal fixation, re-dislocation and instability of atlantoaxial joint, or penetrating of pedicle screw into the spinal canal and the spinal cord occurred. The JOA score was significantly improved to 15.29 +/- 1.38 at 6 months after operation (t = 32.078, P = 0.000). Atlas translaminar screws fixation has the advantages of firm fixation, simple operating techniques, and relative safety, so it may be a remedial measure of atlatoaxial instability.

  12. Strength of surgical wire fixation. A laboratory study.

    PubMed

    Guadagni, J R; Drummond, D S

    1986-08-01

    Because of the frequent use of stainless steel wire in spinal surgery and to augment fracture fixation, several methods of securing wire fixation were tested in the laboratory to determine the relative strength of fixation. Any method of fixation stronger than the yield strength of the wire is sufficient. Square knots, knot twists, symmetric twists, and the AO loop-tuck techniques afforded acceptable resistance against tension loads, but the wire wrap and AO loop technique were unacceptable. The double symmetric twist, which is frequently used for tension banding, was barely acceptable. The symmetric twist technique was the most practical because it is strong enough, efficient in maintaining tension applied during fixation, and least likely to cause damage to the wire. To optimize the fixation strength of the symmetrical twist, at least two twists are required at a reasonably tight pitch.

  13. Planning the Surgical Correction of Spinal Deformities: Toward the Identification of the Biomechanical Principles by Means of Numerical Simulation

    PubMed Central

    Galbusera, Fabio; Bassani, Tito; La Barbera, Luigi; Ottardi, Claudia; Schlager, Benedikt; Brayda-Bruno, Marco; Villa, Tomaso; Wilke, Hans-Joachim

    2015-01-01

    In decades of technical developments after the first surgical corrections of spinal deformities, the set of devices, techniques, and tools available to the surgeons has widened dramatically. Nevertheless, the rate of complications due to mechanical failure of the fixation or the instrumentation remains rather high. Indeed, basic and clinical research about the principles of deformity correction and the optimal surgical strategies (i.e., the choice of the fusion length, the most appropriate instrumentation, and the degree of tolerable correction) did not progress as much as the implantable devices and the surgical techniques. In this work, a software approach for the biomechanical simulation of the correction of patient-specific spinal deformities aimed to the identification of its biomechanical principles is presented. The method is based on three-dimensional reconstructions of the spinal anatomy obtained from biplanar radiographic images. A user-friendly graphical user interface allows for the planning of the desired deformity correction and to simulate the implantation of pedicle screws. Robust meshing of the instrumented spine is provided by using consolidated computational geometry and meshing libraries. Based on a finite element simulation, the program is able to predict the loads and stresses acting in the instrumentation as well as those in the biological tissues. A simple test case (reduction of a low-grade spondylolisthesis at L3–L4) was simulated as a proof of concept, and showed plausible results. Despite the numerous limitations of this approach which will be addressed in future implementations, the preliminary outcome is promising and encourages a wide effort toward its refinement. PMID:26579518

  14. Absent pedicles in campomelic dysplasia.

    PubMed

    McDowell, Michael M; Dede, Ozgur; Bosch, Patrick; Tyler-Kabara, Elizabeth C

    2017-06-01

    The objective of the present study is to report a case of campomelic dysplasia illustrating the absence of cervical and thoracic pedicles. This report reiterates the importance of this clinical peculiarity in the setting of spine instrumentation. A 10-year-old female patient with campomelic dysplasia presented with progressive kyphoscoliosis and signs of neural compromise. Imaging studies confirmed thoracic level stenosis and demonstrated absence of multiple pedicles in cervical and thoracic spine. The patient underwent decompression and instrumentation/fusion for her spinal deformity. The patient was instrumented between C2 and L4 with pedicle screws and sublaminar cables. However, pedicle fixation was not possible for the lower cervical and upper-mid thoracic spine. Also, floating posterior elements precluded the use of laminar fixation in the lower cervical spine. Cervicothoracic lumbosacral orthosis (CTLSO) was used for external immobilization to supplement the tenuous fixation in the cervicothoracic area. The patient improved neurologically with no signs of implant failure at the 2-year follow-up. Absence of pedicles and floating posterior elements present a challenge during spine surgery in campomelic dysplasia. Surgeons should prepare for alternative fixation methods and external immobilization when planning on spinal instrumentation in affected patients. Level IV Case Report.

  15. The biomechanical analysis of sublaminar wires and cables using luque segmental spinal instrumentation.

    PubMed

    Parsons, J R; Chokshi, B V; Lee, C K; Gundlapalli, R V; Stamer, D

    1997-02-01

    Data was gathered from biomechanical testing of 10 thoracic human cadaveric spines. Spines were tested intact and with a Luque rectangle fixed with wire or cable. To compare the rigidity of fixation and intraspinal penetration of sublaminar monofilament wire and multistrand cable under identical conditions using human cadaveric spines. Reports of neurologic and mechanical complications associated with sublaminar wiring techniques have led to the recent development of more flexible multistrand cable systems. The relative performance of flexible cable versus monofilament wire has not been explored fully in a controlled mechanical environment. A servohydraulic mechanical testing machine was used to measure the static mechanical stiffness of sublaminar wire or cable fixation in conjunction with a Luque rectangle for thoracic human cadaveric spine segments in flexion-extension and torsion modes. Cyclic testing was performed in the flexion-extension mode. Intraspinal penetration of wires and cables was measured. Spine fixation with sublaminar wire and cable resulted in constructs of equal stiffness in flexion-extension and torsion modes. Cyclic testing also indicated similar fatigue profiles for wire- and cable-instrumented spines. Wire and cable fixed spines displayed greater stiffness than the intact spines. Cable encroachment of the spinal canal was less than that seen with wire. Sublaminar multistrand cable may be a rational alternative to monofilament wire in segmental spinal instrumentation because it provides less encroachment into the spinal canal. Further, cadaveric spines instrumented with wire and cable display equivalent mechanical behavior, statically and under cyclic loading. The potential advantages of cable, however, must be balanced against a substantial increase in cost relative to wire.

  16. Posterior Vertebral Column Resection for Severe and Rigid Spinal Deformity Associated With Neurological Deficit After Implant Removal Following Posterior Instrumented Fusion: A Case Report and Literature Review.

    PubMed

    Tao, Youping; Wu, Jigong; Ma, Huasong; Zhang, Lele; Shao, Shuilin; Si, Zebing; Gao, Bo; Ji, Yong; Li, Haixia; Tao, Feifei

    2015-07-01

    Case report. To investigate the safety and efficacy of posterior vertebral column resection for severe and rigid spinal deformity associated with neurological deficit after implant removal following posterior instrumented fusion. Loss of correction after implant removal in patients with posterior instrumented fusion has been previously reported. However, to our knowledge, posterior vertebral column resection (PVCR) for severe and rigid spinal deformity associated with neurological deficit after implant removal following posterior instrumented fusion has not been reported. An 18-year-old female with severe and rigid spinal deformity associated with neurological deficit was classified as Frankel C, according to the Frankel grading system. She underwent posterior spinal fusion with pedicle screw fixation at 16 years, and her implants were removed after 1 year due to back pain. Seven months after removal of the implants, she began to experience weakness in her lower limbs but did not seek any treatment. She was unable to stand and had to use a wheelchair. The patient successfully underwent PVCR and posterior reinstrumentation. Within 3 months, her neurological status improved to Frankel E. The patient had no neurological deterioration and infections. There was no instrumentation failure and loosening correction at the 32 months follow-up. Our results suggest that PVCR and pedicle screw fixation is a safe and efficacious option for severe and rigid spinal deformity associated with neurological deficit after implant removal following posterior instrumented fusion. N/A.

  17. A computed tomographic anatomical study of the upper sacrum. Application for a user guide of pelvic fixation with iliosacral screws in adult spinal deformity.

    PubMed

    Dubory, Arnaud; Bouloussa, Houssam; Riouallon, Guillaume; Wolff, Stéphane

    2017-12-01

    Widely used in traumatic pelvic ring fractures, the iliosacral (IS) screw technique for spino-pelvic fixation remains anecdotal in adult spinal deformity. The objective of this study was to assess anatomical variability of the adult upper sacrum and to provide a user guide of spino-pelvic fixation with IS screws in adult spinal deformity. Anatomical variability of the upper sacrum according to age, gender, height and weight was sought on 30 consecutive pelvic CT-scans. Thus, a user guide of spino-pelvic fixation with IS screws was modeled and assessed on ten CT-scans as described below. Two invariable landmarks usable during the surgical procedure were defined: point A (corresponding to the connector binding the IS screw to the spinal rod), equidistant from the first posterior sacral hole and the base of the S1 articular facet and 10 mm-embedded into the sacrum; point B (corresponding to the tip of the IS screw) located at the junction of the anterior third and middle third of the sacral endplate in the sagittal plane and at the middle of the endplate in the coronal plane. Point C corresponded to the intersection between the A-B direction and the external facet of the iliac wing. Three-dimensional reconstructions modeling the IS screw optimal direction according to the A-B-C straight line were assessed. Age had no effect on the anatomy of the upper sacrum. The distance between the base of the S1 superior articular facet and the top of the first posterior sacral hole was correlated with weight (r = 0.6; 95% CI [0.6-0.9]); p < 0.001). Sacral end-plate thickness increased for male patients (p < 0.001) and was strongly correlated with height (r = 0.6; 95% CI [0.29-0.75]); p < 0.001) and weight (r = 0.8; 95% CI [0.6-0.9]); p < 0.001). The thickness of the inferior part of the S1 vertebral body increased in male patients (p < 0.001). Other measured parameters slightly varied according to gender, height and weight. Simulating the described technique of pelvic fixation, no misplaced IS screw was found whatever the age, gender and morphologic parameters. This user guide of spinopelvic fixation with IS screws seems to be reliable and reproducible independently of age, gender and morphologic characteristics but needs clinical assessment. Level IV.

  18. A Novel Junctional Tether Weave Technique for Adult Spinal Deformity: 2-Dimensional Operative Video.

    PubMed

    Buell, Thomas J; Mullin, Jeffrey P; Nguyen, James H; Taylor, Davis G; Garces, Juanita; Mazur, Marcus D; Buchholz, Avery L; Shaffrey, Mark E; Yen, Chun-Po; Shaffrey, Christopher I; Smith, Justin S

    2018-06-05

    Proximal junctional kyphosis (PJK) is a common problem after multilevel spine instrumentation for adult spinal deformity. Various anti-PJK techniques such as junctional tethers for ligamentous augmentation have been proposed. We present an operative video demonstrating technical nuances of junctional tether "weave" application. A 70-yr-old male with prior L2-S1 instrumented fusion presented with worsening back pain and posture. Imaging demonstrated pathological loss of lumbar lordosis (flat back deformity), proximal junctional failure, and pseudarthrosis. The patient had severe global and segmental sagittal malalignment, with sagittal vertical axis (SVA, C7-plumbline) measuring 22.3 cm, pelvic incidence (PI) 55°, lumbar lordosis (LL) 8° in kyphosis, pelvic tilt (PT) 30°, and thoracic kyphosis (TK) 6°. The patient gave informed consent for surgery and use of imaging for medical publication. Briefly, surgery first involved re-instrumentation with bilateral pedicle screws from T10 to S1. After right-sided iliac screw fixation (left-sided iliac screw fixation was not performed due to extensive prior iliac crest bone graft harvesting), we then completed a L2-3 Smith-Petersen osteotomy, extended L4 pedicle subtraction osteotomy, and L3-4 interbody arthrodesis with a 12° lordotic cage (9 × 14 × 40 mm). Cobalt Chromium rods were placed spanning the instrumentation bilaterally, and accessory supplemental rods spanning the PSO were attached. An anti-PJK junctional tether "weave" was then implemented using 4.5 mm polyethylene tape (Mersilene tape [Ethicon, Somerville, New Jersey]). Postoperative imaging demonstrated improved alignment (SVA 2.8 cm, PI 55°, LL 53°, PT 25°, TK 45°) and no significant neurological complications occurred during convalescence or at 6 mo postop.

  19. Is fusion necessary for thoracolumbar burst fracture treated with spinal fixation? A systematic review and meta-analysis.

    PubMed

    Diniz, Juliete M; Botelho, Ricardo V

    2017-11-01

    OBJECTIVE Thoracolumbar fractures account for 90% of spinal fractures, with the burst subtype corresponding to 20% of this total. Controversy regarding the best treatment for this condition remains. The traditional surgical approach, when indicated, involves spinal fixation and arthrodesis. Newer studies have brought the need for fusion associated with internal fixation into question. Not performing arthrodesis could reduce surgical time and intraoperative bleeding without affecting clinical and radiological outcomes. With this study, the authors aimed to assess the effect of fusion, adjuvant to internal fixation, on surgically treated thoracolumbar burst fractures. METHODS A search of the Medline and Cochrane Central Register of Controlled Trials databases was performed to identify randomized trials that compared the use and nonuse of arthrodesis in association with internal fixation for the treatment of thoracolumbar burst fractures. The search encompassed all data in these databases up to February 28, 2016. RESULTS Five randomized/quasi-randomized trials, which involved a total of 220 patients and an average follow-up time of 69.1 months, were included in this review. No significant difference between groups in the final scores of the visual analog pain scale or Low Back Outcome Scale was detected. Surgical time and blood loss were significantly lower in the group of patients who did not undergo fusion (p < 0.05). Among the evaluated radiological outcomes, greater mobility in the affected segment was found in the group of those who did not undergo fusion. No significant difference between groups in the degree of kyphosis correction, loss of kyphosis correction, or final angle of kyphosis was observed. CONCLUSIONS The data reviewed in this study suggest that the use of arthrodesis did not improve clinical outcomes, but it was associated with increased surgical time and higher intraoperative bleeding and did not promote significant improvement in radiological parameters.

  20. Symphyseal internal rod fixation versus standard plate fixation for open book pelvic ring injuries: a biomechanical study.

    PubMed

    Osterhoff, G; Tiziani, S; Hafner, C; Ferguson, S J; Simmen, H-P; Werner, C M L

    2016-04-01

    This study investigates the biomechanical stability of a novel technique for symphyseal internal rod fixation (SYMFIX) using a multiaxial spinal screw-rod implant that allows for direct reduction and can be performed percutaneously and compares it to standard internal plate fixation of the symphysis. Standard plate fixation (PLATE, n = 6) and the SYMFIX (n = 6) were tested on pelvic composite models with a simulated open book injury using a universal testing machine. On a previously described testing setup, 500 consecutive cyclic loadings were applied with sinusoidal resulting forces of 200 N. Displacement under loading was measured using an optoelectronic camera system and construct rigidity was calculated as a function of load and displacement. The rigidity of the PLATE construct was 122.8 N/mm (95 % CI: 110.7-134.8), rigidity of the SYMFIX construct 119.3 N/mm (95 % CI: 105.8-132.7). Displacement in the symphyseal area was mean 0.007 mm (95 % CI: 0.003-0.012) in the PLATE group and 0.021 mm (95 % CI: 0.011-0.031) in the SYMFIX group. Displacement in the sacroiliac joint area was mean 0.156 mm (95 % CI: 0.051-0.261) in the PLATE group and 0.120 mm (95 % CI: 0.039-0.201) in the SYMFIX group. In comparison to standard internal plate fixation for the stabilization of open book pelvic ring injuries, symphyseal internal rod fixation using a multiaxial spinal screw-rod implant in vitro shows a similar rigidity and comparable low degrees of displacement.

  1. Comparative analysis of international standards for the fatigue testing of posterior spinal fixation systems: the importance of preload in ISO 12189.

    PubMed

    La Barbera, Luigi; Ottardi, Claudia; Villa, Tomaso

    2015-10-01

    Preclinical evaluation of the mechanical reliability of fixation devices is a mandatory activity before their introduction into market. There are two standardized protocols for preclinical testing of spinal implants. The American Society for Testing Materials (ASTM) recommends the F1717 standard, which describes a vertebrectomy condition that is relatively simple to implement, whereas the International Organization for Standardization (ISO) suggests the 12189 standard, which describes a more complex physiological anterior support-based setup. Moreover, ASTM F1717 is nowadays well established, whereas ISO 12189 has received little attention: A few studies tried to accurately describe the ISO experimental procedure through numeric models, but these studies totally neglect the recommended precompression step. This study aimed to build up a reliable, validated numeric model capable of describing the stress on the rods of a spinal fixator assembled according to ISO 12189 standard procedure. Such a model would more adequately represent the in vitro testing condition. This study used finite element (FE) simulations and experimental validation testing. An FE model of the ISO setup was built to calculate the stress on the rods. Simulation was validated by comparison with experimental strain gauges measurements. The same fixator has been previously virtually mounted in an L2-L4 FE model of the lumbar spine, and stresses in the rods were calculated when the spine was subjected to physiological forces and moments. The comparison between the FE predictions and experimental measurements is in good agreement, thus confirming the suitability of the FE method to evaluate the stresses in the device. The initial precompression induces a significant extension of the assembled construct. As the applied load increases, the initial extension is gradually compensated, so that at peak load the rods are bent in flexion: The final stress value predicted is thus reduced to about 50%, if compared with the previous model where the precompression was not considered. Neglecting the initial preload due to the assembly of the overall construct according to ISO 12189 standard could lead to an overestimation of the stress on the rods up to 50%. To correctly describe the state of stress on the posterior spinal fixator, tested according to the ISO procedure, it is important to take into account the initial preload due to the assembly of the overall construct. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Primary epidural malignant hemangiopericytoma of thoracic spinal column causing cord compression: case report.

    PubMed

    Mohammadianpanah, Mohammad; Torabinejad, Simin; Bagheri, Mohammad Hadi; Omidvari, Shapour; Mosalaei, Ahmad; Ahmadloo, Niloofar

    2004-09-02

    Hemangiopericytoma is an uncommon mesenchymal neoplasm that rarely affects the spinal canal. Primary malignant hemangiopericytoma of the spinal column is extremely rare. We report on a case of primary epidural malignant hemangiopericytoma of the thoracic spinal column that invaded vertebral bone and caused spinal cord compression in a 21-year-old man. The patient presented with progressive back pain over a four-month period that progressed to paraparesis, bilateral leg paresthesia and urinary incontinence. The surgical intervention involved laminectomy and subtotal resection of the tumor, with posterior vertebral fixation. Postoperative involved-field radiotherapy was administered. A marked neurological improvement was subsequently observed. We describe the clinical, radiological, and histological features of this tumor and review the literature.

  3. Risk analysis based on the timing of tracheostomy procedures in patients with spinal cord injury requiring cervical spine surgery.

    PubMed

    Galeiras, Rita; Mourelo, Mónica; Bouza, María Teresa; Seoane, María Teresa; Ferreiro, María Elena; Montoto, Antonio; Salvador, Sebastián; Seoane, Leticia; Freire, David

    2018-05-19

    To determine the optimal moment to carry out a tracheostomy in a patient requiring anterior cervical fixation. A retrospective observational study was carried out over an 18-year period on 56 patients who had been admitted to the ICU with acute spinal cord injury (SCI), and who underwent a tracheostomy and surgical fixation. The sample was divided into two groups: An at-risk group (31 patients, who had undergone a tracheostomy prior to the cervical surgery or <4 days after the procedure), and a not at-risk group (25 patients, who had undergone a tracheostomy >4 day following the fixation surgery). Both a descriptive and a comparative study were carried out. The overall trend of the collected data was analysed using cubic splines (graphic methods). The only infectious complications diagnosed as related to the surgical procedure were infection of the surgical wound in two patients of the not at-risk group (12%) and deep-tissue infection in one patient of the at-risk group (3.2%). During the study period, we identified a tendency towards the conduct of early tracheostomies. Our results suggest that the presence of a tracheostomy stoma prior to, or immediately after surgery, is associated with a low risk of infection of the cervical surgical wound in instrumented spinal fusion. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Surgical Management of Spinal Conditions in the Elderly Osteoporotic Spine.

    PubMed

    Goldstein, Christina L; Brodke, Darrel S; Choma, Theodore J

    2015-10-01

    Osteoporosis, the most common form of metabolic bone disease, leads to alterations in bone structure and density that have been shown to compromise the strength of spinal instrumentation. In addition, osteoporosis may contribute to high rates of fracture and instrumentation failure after long posterior spinal fusions, resulting in proximal junctional kyphosis and recurrent spinal deformity. As increasing numbers of elderly patients present for surgical intervention for degenerative and traumatic spinal pathologies, current and future generations of spine surgeons will increasingly be faced with the challenge of obtaining adequate fixation in osteoporotic bone. The purpose of this review is to familiarize the reader with the impact of osteoporosis on spinal instrumentation, the broad variety of techniques that have been developed for addressing these issues, and the biomechanical and clinical evidence in support of the use of these techniques.

  5. Comparison of a novel fixation device with standard suturing methods for spinal cord stimulators.

    PubMed

    Bowman, Richard G; Caraway, David; Bentley, Ishmael

    2013-01-01

    Spinal cord stimulation is a well-established treatment for chronic neuropathic pain of the trunk or limbs. Currently, the standard method of fixation is to affix the leads of the neuromodulation device to soft tissue, fascia or ligament, through the use of manually tying general suture. A novel semiautomated device is proposed that may be advantageous to the current standard. Comparison testing in an excised caprine spine and simulated bench top model was performed. Three tests were performed: 1) perpendicular pull from fascia of caprine spine; 2) axial pull from fascia of caprine spine; and 3) axial pull from Mylar film. Six samples of each configuration were tested for each scenario. Standard 2-0 Ethibond was compared with a novel semiautomated device (Anulex fiXate). Upon completion of testing statistical analysis was performed for each scenario. For perpendicular pull in the caprine spine, the failure load for standard suture was 8.95 lbs with a standard deviation of 1.39 whereas for fiXate the load was 15.93 lbs with a standard deviation of 2.09. For axial pull in the caprine spine, the failure load for standard suture was 6.79 lbs with a standard deviation of 1.55 whereas for fiXate the load was 12.31 lbs with a standard deviation of 4.26. For axial pull in Mylar film, the failure load for standard suture was 10.87 lbs with a standard deviation of 1.56 whereas for fiXate the load was 19.54 lbs with a standard deviation of 2.24. These data suggest a novel semiautomated device offers a method of fixation that may be utilized in lieu of standard suturing methods as a means of securing neuromodulation devices. Data suggest the novel semiautomated device in fact may provide a more secure fixation than standard suturing methods. © 2012 International Neuromodulation Society.

  6. Stress analysis in a pedicle screw fixation system with flexible rods in the lumbar spine.

    PubMed

    Kim, Kyungsoo; Park, Won Man; Kim, Yoon Hyuk; Lee, SuKyoung

    2010-01-01

    Breakage of screws has been one of the most common complications in spinal fixation systems. However, no studies have examined the breakage risk of pedicle screw fixation systems that use flexible rods, even though flexible rods are currently being used for dynamic stabilization. In this study, the risk of breakage of screws for the rods with various flexibilities in pedicle screw fixation systems is investigated by calculating the von Mises stress as a breakage risk factor using finite element analysis. Three-dimensional finite element models of the lumbar spine with posterior one-level spinal fixations at L4-L5 using four types of rod (a straight rod, a 4 mm spring rod, a 3 mm spring rod, and a 2 mm spring rod) were developed. The von Mises stresses in both the pedicle screws and the rods were analysed under flexion, extension, lateral bending, and torsion moments of 10 Nm with a follower load of 400 N. The maximum von Mises stress, which was concentrated on the neck region of the pedicle screw, decreased as the flexibility of the rod increased. However, the ratio of the maximum stress in the rod to the yield stress increased substantially when a highly flexible rod was used. Thus, the level of rod flexibility should be considered carefully when using flexible rods for dynamic stabilization because the intersegmental motion facilitated by the flexible rod results in rod breakage.

  7. Fixation Time; Technical Report 7. Disadvantaged Children and Their First School Experiences. ETS-Head Start Longitudinal Study. Technical Report Series.

    ERIC Educational Resources Information Center

    Shipman, Virginia C.; Goldman, Karla S.

    The fixation task used in this study measures the amount of time a child fixates or looks at a given picture as it is repeated over six trials and then is followed by a novel picture on the seventh. Two series of slides were used. The first was a redundant nonsocial visual stimulus: six trials of a slide showing 20 chromatic straight lines and a…

  8. Relevance of Postoperative Magnetic Resonance Images in Evaluating Epidural Hematoma After Thoracic Fixation Surgery.

    PubMed

    Shin, Hong Kyung; Choi, Il; Roh, Sung Woo; Rhim, Seung Chul; Jeon, Sang Ryong

    2017-11-01

    It is difficult to evaluate the significant findings of epidural hematoma in magnetic resonance images (MRIs) obtained immediately after thoracic posterior screw fixation (PSF). Prospectively, immediate postoperative MRI was performed in 10 patients who underwent thoracic PSF from April to December 2013. Additionally, we retrospectively analyzed the MRIs from 3 patients before hematoma evacuation out of 260 patients who underwent thoracic PSF from January 2000 to March 2013. The MRI findings of 9 out of the 10 patients, consecutively collected after thoracic PSF, showed neurologic recovery with a well-preserved cerebrospinal fluid (CSF) space and no prominent hemorrhage. Even though there were metal artifacts at the level of the pedicle screws, the preserved CSF space was observed. In contrast, the MRI of 1 patient with poor neurologic outcome demonstrated a typical hematoma and slight spinal cord compression and reduced CSF space. In the retrospective analysis of the 3 patients who showed definite motor weakness in the lower extremities after their first thoracic fusion surgery and underwent hematoma evacuation, the magnetic resonance images before hematoma evacuation also revealed hematoma compressing the spinal cord and diminished CSF space. This study shows that epidural hematomas can be detected on MRI performed immediately after thoracic fixation surgery, despite metal artifacts and findings such as hematoma causing spinal cord compression. Loss of CSF space should be considered to be associated with neurologic deficit. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Temporary short-segment pedicle screw fixation for thoracolumbar burst fractures: comparative study with or without vertebroplasty.

    PubMed

    Aono, Hiroyuki; Ishii, Keisuke; Tobimatsu, Hidekazu; Nagamoto, Yukitaka; Takenaka, Shota; Furuya, Masayuki; Chiaki, Horii; Iwasaki, Motoki

    2017-08-01

    Short-segment posterior spinal instrumentation for thoracolumbar burst fracture provides superior correction of kyphosis by an indirect reduction technique, but it has a high failure rate. The purpose of the study we report here was to compare outcomes for temporary short-segment pedicle screw fixation with vertebroplasty and for such fixation without vertebroplasty. This is a prospective multicenter comparative study. We studied 62 consecutive patients with thoracolumbar burst fracture who underwent short-segment posterior instrumentation using ligamentotaxis with Schanz screws with or without vertebroplasty. Radiological parameters (Cobb angle on standing lateral radiographs) were used. Implants were removed approximately 1 year after surgery. Neurologic function, kyphotic deformity, canal compromise, and fracture severity were evaluated prospectively. After surgery, all patients with neurologic deficit had improvement equivalent to at least one grade on the American Spinal Injury Association impairment scale and had fracture union. Kyphotic deformity was reduced significantly, and reduction of the vertebrae was maintained with and without vertebroplasty, regardless of load-sharing classification. Although no patient required additional anterior reconstruction, kyphotic change was observed at disc level mainly after implant removal with or without vertebroplasty. Temporary short-segment fixation yielded satisfactory results in the reduction and maintenance of fractured vertebrae with or without vertebroplasty. Kyphosis recurrence may be inevitable because adjacent discs can be injured during the original trauma. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Surgical correction of severe spinal deformities using a staged protocol of external and internal techniques.

    PubMed

    Prudnikova, Oksana G; Shchurova, Elena N

    2018-02-01

    There is high risk of neurologic complications in one-stage management of severe rigid spinal deformities in adolescents. Therefore, gradual spine stretching variants are applied. One of them is the use of external transpedicular fixation. Our aim was to retrospectively study the outcomes of gradual correction with an apparatus for external transpedicular fixation followed by internal fixation used for high-grade kyphoscoliosis in adolescents. Twenty five patients were reviewed (mean age, 15.1 ± 0.4 years). Correction was performed in two stages: 1) gradual controlled correction with the apparatus for external transpedicular fixation; and 2) internal posterior transpedicular fixation. Rigid deformities in eight patients required discapophysectomy. Clinical and radiographic study of the outcomes was conducted immediately after treatment and at a mean long-term period of 3.8 ± 0.4 years. Pain was evaluated using the visual analogue scale (VAS, 10 points). The Oswestry questionnaire (ODI scale) was used for functional assessment. Deformity correction with the external apparatus was 64.2 ± 4.6% in the main curve and 60.7 ± 3.7% in the compensatory one. It was 72.8 ± 4.1% and 66.2 ± 5.3% immediately after treatment and 70.8 ± 4.6% and 64.3 ± 4.2% at long term, respectively. Pain relieved by 33.2 ± 4.2% (p < 0.05) immediately after treatment and by 55.6 ± 2.8% (p < 0.05) at long term. ODI reduced by 30.2 ± 1.7% (p < 0.05) immediately after treatment and by 37.2 ± 1.6% (p < 0.05) at long term. The apparatus for external transpedicular fixation provides gradual controlled correction for high-grade kyphoscoliosis in adolescents. Transition to internal fixation preserves the correction achieved, and correction is maintained at long term.

  11. Management of Lower Extremity Long-bone Fractures in Spinal Cord Injury Patients.

    PubMed

    Schulte, Leah M; Scully, Ryan D; Kappa, Jason E

    2017-09-01

    The AO classification system, used as a guide for modern fracture care and fixation, follows a basic philosophy of care that emphasizes early mobility and return to function. Lower extremity long-bone fractures in patients with spinal cord injury often are pathologic injuries that present unique challenges, to which the AO principles may not be entirely applicable. Optimal treatment achieves healing without affecting the functional level of the patient. These injuries often result from low-energy mechanisms in nonambulatory patients with osteopenic bone and a thin, insensate soft-tissue envelope. The complication rate can be high, and the outcomes can be catastrophic without proper care. Satisfactory results can be obtained through various methods of immobilization. Less frequently, internal fixation is applied. In certain cases, after discussion with the patient, amputation may be suitable. Prevention strategies aim to minimize bone loss and muscle atrophy.

  12. ASTM F1717 standard for the preclinical evaluation of posterior spinal fixators: can we improve it?

    PubMed

    La Barbera, Luigi; Galbusera, Fabio; Villa, Tomaso; Costa, Francesco; Wilke, Hans-Joachim

    2014-10-01

    Preclinical evaluation of spinal implants is a necessary step to ensure their reliability and safety before implantation. The American Society for Testing and Materials reapproved F1717 standard for the assessment of mechanical properties of posterior spinal fixators, which simulates a vertebrectomy model and recommends mimicking vertebral bodies using polyethylene blocks. This set-up should represent the clinical use, but available data in the literature are few. Anatomical parameters depending on the spinal level were compared to published data or measurements on biplanar stereoradiography on 13 patients. Other mechanical variables, describing implant design were considered, and all parameters were investigated using a numerical parametric finite element model. Stress values were calculated by considering either the combination of the average values for each parameter or their worst-case combination depending on the spinal level. The standard set-up represents quite well the anatomy of an instrumented average thoracolumbar segment. The stress on the pedicular screw is significantly influenced by the lever arm of the applied load, the unsupported screw length, the position of the centre of rotation of the functional spine unit and the pedicular inclination with respect to the sagittal plane. The worst-case combination of parameters demonstrates that devices implanted below T5 could potentially undergo higher stresses than those described in the standard suggestions (maximum increase of 22.2% at L1). We propose to revise F1717 in order to describe the anatomical worst case condition we found at L1 level: this will guarantee higher safety of the implant for a wider population of patients. © IMechE 2014.

  13. [Treatment of thoracolumbar tumors with total en bloc spondylectomy and the results of spinal stability reconstruction].

    PubMed

    Yang, Qiang; Li, Jian-min; Yang, Zhi-ping; Li, Xin; Li, Zhen-feng; Yan, Jun

    2013-03-01

    To investigate the therapeutic effect of total en bloc spondylectomy (TES) for thoracolumbar tumors and the results of spinal stability reconstruction. From January 2007 to June 2011 there were 18 patients with thoracolumbar tumors distributed in the thoracic vertebrae (n = 10) and lumbar vertebrae (n = 8). There were 7 haemangiomas, 5 giant cell tumors of bone, 1 malignant schwannoma, 1 solitary plasmocytoma, 1 neuroblastoma, 1 osteoblastoma, 1 metastatic malignant fibrous histiocytoma, and 1 metastasis of breast cancer. All the 18 patients were treated with improved TES under electrophysiological monitoring of spinal cord. Four patients were treated through one-stage combined anteroposterior approach and 14 patients through one-stage posterior approach. The anterior reconstructions included titanium mesh cages filled with bone or bone cement in 15 cases, titanium mesh cage with strengthened rings in 2 cases and artificial vertebral body replacement in 1 case. The posterior reconstruction included multiple segmental fixation with pedicle screw-rod system in 15 cases and short segmental fixation in 3 cases. Massive bone auto-graft was employed in 13 cases and fragmental bone graft in 5 cases. The total en bloc spondylectomy was performed successfully in 15 patients and unsuccessful in 3 whose spinal tumors were resected by piecemeal technique. In 15 patients with successfully performed TES, the duration of surgery was from 340 to 610 min (average, 450.7 min), the blood loss was from 3000 to 10 200 ml (average, 4850 ml), and the intraoperative blood transfusion was from 2800 to 9600 ml (average, 4200 ml). The operation-related complications comprised hemopneumothorax, intercostal nerve pain, stress ulcer and bleeding, and so on. One year after operation, the patients with neurological dysfunction recovered from grade A to grade D in one patient, and to grade E in the other 14 cases. The average visual analog scale (VAS) scores was 0.5. One patient with plasmacytoma and another one with L5 metastatic tumor suffered progression of the disease and were living with the diseases. The patient with metastatic malignant fibrous histiocytoma died of local recurrence and lung metastasis 16 months postoperatively. One patient with L4 neuroblastoma died of other reason and all the rest were free from relapse. The Cobb angle of upper and lower vertebral body adjacent to the involved vertebrae in sagittal plane was from -26.7° to 12.0° (average, -2.57°) just postoperatively and from -17.5° to 57.2° (average, 11.5°) at the last follow-up or before reoperation. There were 2 patients with screw-rod breakdown and 2 patients with internal fixation loosening. The measurement of titanium mesh cage subsided into adjacent vertebral bodies was average 7.5 mm. The revision surgery was performed in 3 patients, through combined anteroposterior approach in 2 and only posterior approach in 1 patient. TES significantly increases the therapeutic effect of spinal tumors, although accompanied with high difficulty and massive bleeding. In spinal stability reconstruction after total spondylectomy, it should be emphasized that posterior long segment fixation with pedicle screw-rod system, massive bone bridging graft and the application of thoracolumbosacral orthosis can achieve short-term firm fixation and long-term fusion-stabilization.

  14. Desktop-based computer-assisted orthopedic training system for spinal surgery.

    PubMed

    Rambani, Rohit; Ward, James; Viant, Warren

    2014-01-01

    Simulation and surgical training has moved on since its inception during the end of the last century. The trainees are getting more exposed to computers and laboratory training in different subspecialties. More needs to be done in orthopedic simulation in spinal surgery. To develop a training system for pedicle screw fixation and validate its effectiveness in a cohort of junior orthopedic trainees. Fully simulated computer-navigated training system is used to train junior orthopedic trainees perform pedicle screw insertion in the lumbar spine. Real patient computed tomography scans are used to produce the real-time fluoroscopic images of the lumbar spine. The training system was developed to simulate pedicle screw insertion in the lumbar spine. A total of 12 orthopedic senior house officers performed pedicle screw insertion in the lumbar spine before and after the training on training system. The results were assessed based on the scoring system, which included the amount of time taken, accuracy of pedicle screw insertion, and the number of exposures requested to complete the procedure. The result shows a significant improvement in amount of time taken, accuracy of fixation, and the number of exposures after the training on simulator system. This was statistically significant using paired Student t test (p < 0.05). Fully simulated computer-navigated training system is an efficient training tool for young orthopedic trainees. This system can be used to augment training in the operating room, and trainees acquire their skills in the comfort of their study room or in the training room in the hospital. The system has the potential to be used in various other orthopedic procedures for learning of technical skills in a manner aimed at ensuring a smooth escalation in task complexity leading to the better performance of procedures in the operating theater. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  15. Computer-assisted spinal osteotomy: a technical note and report of four cases.

    PubMed

    Fujibayashi, Shunsuke; Neo, Masashi; Takemoto, Mitsuru; Ota, Masato; Nakayama, Tomitaka; Toguchida, Junya; Nakamura, Takashi

    2010-08-15

    A report of 4 cases of spinal osteotomy performed under the guidance of a computer-assisted navigation system and a technical note about the use of the navigation system for spinal osteotomy. To document the surgical technique and usefulness of computer-assisted surgery for spinal osteotomy. A computer-assisted navigation system provides accurate 3-dimensional (3D) real-time surgical information during the operation. Although there are many reports on the accuracy and usefulness of a navigation system for pedicle screw placement, there are few reports on the application for spinal osteotomy. We report on 4 complex cases including 3 solitary malignant spinal tumors and 1 spinal kyphotic deformity of ankylosing spondylitis, which were treated surgically using a computer-assisted spinal osteotomy. The surgical technique and postoperative clinical and radiologic results are presented. 3D spinal osteotomy under the guidance of a computer-assisted navigation system was performed successfully in 4 patients. All malignant tumors were resected en bloc, and the spinal deformity was corrected precisely according to the preoperative plan. Pathologic analysis confirmed the en bloc resection without tumor exposure in the 3 patients with a spinal tumor. The use of a computer-assisted navigation system will help ensure the safety and efficacy of a complex 3D spinal osteotomy.

  16. Transoesophageal spinal cord stimulation for motor-evoked potentials monitoring: feasibility, safety and stability.

    PubMed

    Tsuda, Kazumasa; Shiiya, Norihiko; Takahashi, Daisuke; Ohkura, Kazuhiro; Yamashita, Katsushi; Kando, Yumi

    2015-08-01

    Specificity of transcranial motor-evoked potentials (MEPs) is low because amplitude fluctuation is common, which seems due to several technical and fundamental reasons including difficulty in electrodes positioning and fixation for transcranial stimulation and susceptibility to anaesthesia. This study aimed to investigate the feasibility, safety and stability of our novel technique of transoesophageal spinal cord stimulation to improve the stability of MEPs. Ten anaesthetized adult beagle dogs were used. Transoesophageal stimulation was performed between the oesophageal luminal surface electrode (cathode) and a subcutaneous needle electrode (anode) at the fourth to fifth thoracic vertebra level. Stimulation was achieved with a train of five pulses delivered at 2.0-ms intervals. Compound muscle action potentials were recorded from four limbs and external anal sphincter muscles. Stability to anaesthetic agents was tested at varying speeds of propofol and remifentanil, and effects of varying concentration of sevoflurane inhalation were also evaluated. Transoesophageal MEPs could be recorded without difficulty in all dogs. Fluoroscopic evaluation showed that electrodes misalignment up to 5 cm cranially or caudally could be tolerated. Stimulus intensity to achieve maximum amplitude of hindlimb muscle potentials on both sides was significantly lower by transoesophageal stimulation than by transcranial stimulation (383 ± 41 vs 533 ± 121 V, P = 0.02) and had less interindividual variability. Latency of transoesophageal MEPs was shorter than that of transcranial MEPs at every recording point. No arrhythmia was provoked during stimulation. Animals that were allowed to recover showed no neurological abnormality. In the two sacrificed animals, the explanted oesophagus showed no mucosal injury. Stability to varying dose of anaesthetic agents was similar between transoesophageal and transcranial stimulation, except for the potentials of forelimbs by transoesophageal stimulation that were resistant to anaesthetic depression. Transoesophageal stimulation for MEPs monitoring was feasible without difficulty and safe. Although its stability to anaesthetic agents was similar to that of transcranial stimulation, its technical ease and small interindividual variability warrants further studies on the response to spinal cord ischaemia. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  17. A pilot study of the utility of a laboratory-based spinal fixation training program for neurosurgical residents.

    PubMed

    Sundar, Swetha J; Healy, Andrew T; Kshettry, Varun R; Mroz, Thomas E; Schlenk, Richard; Benzel, Edward C

    2016-05-01

    OBJECTIVE Pedicle and lateral mass screw placement is technically demanding due to complex 3D spinal anatomy that is not easily visualized. Neurosurgical and orthopedic surgery residents must be properly trained in such procedures, which can be associated with significant complications and associated morbidity. Current training in pedicle and lateral mass screw placement involves didactic teaching and supervised placement in the operating room. The objective of this study was to assess whether teaching residents to place pedicle and lateral mass screws using navigation software, combined with practice using cadaveric specimens and Sawbones models, would improve screw placement accuracy. METHODS This was a single-blinded, prospective, randomized pilot study with 8 junior neurosurgical residents and 2 senior medical students with prior neurosurgery exposure. Both the study group and the level of training-matched control group (each group with 4 level of training-matched residents and 1 senior medical student) were exposed to a standardized didactic education regarding spinal anatomy and screw placement techniques. The study group was exposed to an additional pilot program that included a training session using navigation software combined with cadaveric specimens and accessibility to Sawbones models. RESULTS A statistically significant reduction in overall surgical error was observed in the study group compared with the control group (p = 0.04). Analysis by spinal region demonstrated a significant reduction in surgical error in the thoracic and lumbar regions in the study group compared with controls (p = 0.02 and p = 0.04, respectively). The study group also was observed to place screws more optimally in the cervical, thoracic, and lumbar regions (p = 0.02, p = 0.04, and p = 0.04, respectively). CONCLUSIONS Surgical resident education in pedicle and lateral mass screw placement is a priority for training programs. This study demonstrated that compared with a didactic-only training model, using navigation simulation with cadavers and Sawbones models significantly reduced the number of screw placement errors in a laboratory setting.

  18. Congenital cervical kyphosis in an infant with Ehlers-Danlos syndrome.

    PubMed

    Kobets, Andrew J; Komlos, Daniel; Houten, John K

    2018-07-01

    Ehler-Danlos syndome (EDS) refers to a group of heritable connective tissue disorders; rare manifestations of which are cervical kyphosis and clinical myelopathy. Surgical treatment is described for the deformity in the thoracolumbar spine in adolescents but not for infantile cervical spine. Internal fixation for deformity correction in the infantile cervical spine is challenging due to the diminutive size of the bony anatomy and the lack of spinal instrumentation specifically designed for young children. We describe the first case of successful surgical treatment in an infant with a high cervical kyphotic deformity in EDS. A 15-month-old female with EDS presented with several months of regression in gross motor skills in all four extremities. Imaging demonstrated 45° of kyphosis from the C2-4 levels with spinal cord compression. Corrective surgery consisted of a C3 corpectomy and C2-4 anterior fusion with allograft block and anterior fixation with dual 2 × 2 hole craniofacial miniplates, supplemented by C2-4 posterior fusion using four craniofacial miniplates fixated to the lamina. Radiographs at 20 months post-surgery demonstrated solid fusion both anteriorly and posteriorly with maintenance of correction. Ehlers-Danlos syndrome may present in the pediatric population with congenital kyphosis from cervical deformity in addition to the more commonly seen thoracolumbar deformities.

  19. The Incidence of Adjacent Segment Degeneration after the Use of a Versatile Dynamic Hybrid Stabilization Device in Lumbar Stenosis: Results of a 5–8-Year Follow-up

    PubMed Central

    Dobran, Mauro; Esposito, Domenico Paolo; Gladi, Maurizio; Scerrati, Massimo; Iacoangeli, Maurizio

    2018-01-01

    Study Design Retrospective study with long-term follow-up. Purpose To evaluate the long-term incidence of adjacent segment degeneration (ASD) and clinical outcomes in a consecutive series of patients who underwent spinal decompression associated with dynamic or hybrid stabilization with a Flex+TM stabilization system (SpineVision, Antony, France) for lumbar spinal stenosis. Overview of Literature The incidence of ASD and clinical outcomes following dynamic or hybrid stabilization with the Flex+TM system used for lumbar spinal stenosis have not been well investigated. Methods Twenty-one patients with lumbar stenosis and probable post-decompressive spinal instability underwent decompressive laminectomy followed by spinal stabilization using the Flex+TM stabilization system. The indication for a mono-level dynamic stabilization was a preoperative magnetic resonance imaging (MRI) demonstrating evidence of severe disc disease associated with severe spinal stenosis. The hybrid stabilization (rigid-dynamic) system was used for multilevel laminectomies with associated initial degenerative scoliosis, first-grade spondylolisthesis, or rostral pathology. Results The improvement in Visual Analog Scale and Oswestry Disability Index scores at follow-up were statistically significant (p<0.0001 and p<0.0001, respectively). At the 5–8-year follow-up, clinical examination, MRI, and X-ray findings showed an ASD complication with pain and disability in one of 21 patients. The clinical outcomes were similar in patients treated with dynamic or hybrid fixation. Conclusions Patients treated with laminectomy and Flex+TM stabilization presented a satisfactory clinical outcome after 5–8 years of follow-up, and ASD incidence in our series was 4.76% (one patient out of 21). We are aware that this is a small series, but our long-term follow-up may be sufficient to contribute to the expanding body of literature on the development of symptomatic ASD associated with dynamic or hybrid fixation. PMID:29713407

  20. Stent migration following endoscopic suture fixation of esophageal self-expandable metal stents: a systematic review and meta-analysis.

    PubMed

    Law, Ryan; Prabhu, Anoop; Fujii-Lau, Larissa; Shannon, Carol; Singh, Siddharth

    2018-02-01

    Covered self-expandable metal stents (SEMS) are utilized for the management of benign and malignant esophageal conditions; however, covered SEMS are prone to migration. Endoscopic suture fixation may mitigate the migration risk of covered esophageal SEMS. Hence, we conducted a systematic review and meta-analysis to evaluate the effectiveness and safety of endoscopic suture fixation for covered esophageal SEMS. Following PRISMA guidelines, we performed a systematic review from 2011 to 2016 to identify studies (case control/case series) reporting the technical success and migration rate of covered esophageal SEMS following endoscopic suture fixation. We searched multiple electronic databases and conference proceedings. We calculated pooled rates (and 95% confidence intervals [CI]) of technical success and stent migration using a random effects model. We identified 14 studies (212 patients) describing covered esophageal SEMS placement with endoscopic suture fixation. When reported, SEMS indications included leak/fistula (n = 75), stricture (n = 65), perforation (n = 10), and achalasia (n = 4). The pooled technical success rate was 96.7% (95% CI 92.3-98.6), without heterogeneity (I 2  = 0%). We identified 29 SEMS migrations at rate of 15.9% (95% CI 11.4-21.6), without heterogeneity (I 2  = 0%). Publication bias was observed, and using the trim-and-fill method, a more conservative estimate for stent migration was 17.0%. Suture-related adverse events were estimated to occur in 3.7% (95% CI 1.6-8.2) of cases. Endoscopic suture fixation of covered esophageal SEMS appears to reduce stent migration when compared to published rates of non-anchored SEMS. However, SEMS migration still occurs in approximately 1 out of 6 cases despite excellent immediate technical success and low risk of suture-related adverse events.

  1. Unstable upper and middle thoracic fractures. Preliminary experience with a posterior transpedicular correction-fixation technique.

    PubMed

    Payer, M

    2005-06-01

    A number of conservative and operative approaches have been described for the treatment of unstable traumatic upper and middle thoracic fractures. The advantage of surgical correction and fixation/fusion lies in its potential to restore sagittal and coronal alignment, thereby indirectly decompressing the spinal cord. A consecutive series of 8 patients with unstable traumatic upper and middle thoracic fractures is reviewed. In all patients, polyaxial pedicle screws were inserted bilaterally into the two levels above and below the fracture. Rods that were less contoured ("undercontoured") than the regional hyperkyphosis at the injured level, were anchored to the caudal four screws. The cranial four screws, with the vertebrae to which they were inserted, were then progressively pulled posteriorly onto the undercontoured rods with rod reducers, thus correcting the hyperkyphosis and anterolisthesis. The mean follow-up was 15 months. The mean regional kyphosis was 23 degrees preoperatively, 17 degrees postoperatively and 18 degrees at follow-up. The mean anterolisthesis was 8 mm preoperatively, 1 mm postoperatively and 1 mm at follow-up. No hardware failure occurred. Five patients with complete spinal cord injury at presentation made no neurological recovery, two patients with incomplete spinal cord injury initially (ASIA B), recovered substantially (to ASIA D), and the patients who were neurologically intact at presentation remained so.

  2. Frontiers in Head and Neck Trauma: Clinical and Biomechanical.

    DTIC Science & Technology

    1998-06-19

    Minerva fixation. As previously noted however, lateral mass plates have the risk for neurovascular injury (nerve root, vertebral artery), foraminal ...cord ischemia in CSM to include compromise of the anterior spinal veins, radicular arteries at the foraminal region, and vertebral artery narrowing as

  3. Mechanics of external fixation device of spine: reducing the mounting stress

    NASA Astrophysics Data System (ADS)

    Piven, V. V.; Lyulin, S. V.; Kovalenko, P. I.; Mushtaeva, Yu A.

    2018-03-01

    During the installation of the external fixation device on the spine, there is an occurrence of mounting stress due to misalignment of the rod-screws. To determine the magnitude of the mounting stresses, mathematical dependencies are sometimes used. The proposed technical solution is to reduce stress in the external fixation device.

  4. Rigid Posterior Lumbopelvic Fixation without Formal Debridement for Pyogenic Vertebral Diskitis and Osteomyelitis Involving the Lumbosacral Junction: Technical Report.

    PubMed

    Mazur, Marcus D; Ravindra, Vijay M; Dailey, Andrew T; McEvoy, Sara; Schmidt, Meic H

    2015-01-01

    Pelvic fixation with S2-alar-iliac (S2AI) screws can increase the rigidity of a lumbosacral construct, which may promote bone healing, improve antibiotic delivery to infected tissues, and avoid L5-S1 pseudarthrosis. To describe the use of single-stage posterior fixation without debridement for the treatment of pyogenic vertebral diskitis and osteomyelitis (PVDO) at the lumbosacral junction. Technical report. We describe the management of PVDO at the lumbosacral junction in which the infection invaded the endplates, disk space, vertebrae, prevertebral soft tissues, and epidural space. Pedicle involvement precluded screw fixation at L5. Surgical management consisted of a single-stage posterior operation with rigid lumbopelvic fixation augmented with S2-alar-iliac screws and without formal debridement of the infected area, followed by long-term antibiotic treatment. At 2-year follow-up, successful fusion and eradication of the infection were achieved. PVDO at the lumbosacral junction may be treated successfully using rigid posterior-only fixation without formal debridement combined with antibiotic therapy.

  5. Problems of long-term spinal opioid treatment in advanced cancer patients.

    PubMed

    Mercadante, S

    1999-01-01

    Epidural and intrathecal techniques are well established techniques in cancer pain. However, several questions remain unresolved. The several problems of long-term spinal opioid treatment in advance cancer patients were reviewed. Indications for the use of spinal opioids include patients treated by systemic opioids with effective pain relief but with unacceptable side effects, or unsuccessful treatment with sequential strong opioid drug trials despite escalating doses. Therefore, the previous aggressive treatment with systemic opioids would leave as failures patients with difficult pain syndromes unresponsive to opioids. The choice of external or totally implanted delivery systems is based on different clinical considerations. The use of externalized tunneled intrathecal catheters has not been associated with higher rates of complications and is easier to place and use at home in debilitated patients late in the course of their disease. The intrathecal administration has a lower incidence of catheter occlusion, lower malfunctioning rate, lower dose requirement, and more effective pain control. Due to the lower daily doses and volumes, intrathecal treatment proved to be more suitable for treatment at home by a continuous infusion than the epidural treatment. Advantages of infusion techniques are more evident when using local anesthetics, since intermittent administration of bupivacaine often results in motor paralysis and hemodynamic instability. Morphine is the opioid of choice. An epidural dose of 10% of the systemic dose is often used. However, intrathecal administration of opioids and bupivacaine may substantially improve pain relief in patients unresponsive to high epidural doses of these drugs, Bupivacaine-induced adverse effects, including sensory deficits, motor complaints, signs of autonomic dysfunction or neurotoxicity have been reported to not occur with bupivacaine doses less than 30-60 mg/day. Adjuvant drugs may further improve analgesia. Different ranges of technical complication rates have been reported in the literature, most of them being associated with epidural catheters. Subcutaneous tunneling and fixation of the catheter, bacterial filters, minimum changes of tubings, careful exit site care weekly, site protection and monitoring of any sign of infection to prevent infection, and training for family under supervision, are recommended. Areas for additional research include the use of spinal adjuvants, the ideal spinal morphine-bupivacaine ratio. methods to improve spinal opioid responsiveness and long-term catheter management with appropriate home care programs.

  6. Simulated spinal cerebrospinal fluid leak repair: an educational model with didactic and technical components.

    PubMed

    Ghobrial, George M; Anderson, Paul A; Chitale, Rohan; Campbell, Peter G; Lobel, Darlene A; Harrop, James

    2013-10-01

    In the era of surgical resident work hour restrictions, the traditional apprenticeship model may provide fewer hours for neurosurgical residents to hone technical skills. Spinal dura mater closure or repair is 1 skill that is infrequently encountered, and persistent cerebrospinal fluid leaks are a potential morbidity. To establish an educational curriculum to train residents in spinal dura mater closure with a novel durotomy repair model. The Congress of Neurological Surgeons has developed a simulation-based model for durotomy closure with the ongoing efforts of their simulation educational committee. The core curriculum consists of didactic training materials and a technical simulation model of dural repair for the lumbar spine. Didactic pretest scores ranged from 4/11 (36%) to 10/11 (91%). Posttest scores ranged from 8/11 (73%) to 11/11 (100%). Overall, didactic improvements were demonstrated by all participants, with a mean improvement between pre- and posttest scores of 1.17 (18.5%; P = .02). The technical component consisted of 11 durotomy closures by 6 participants, where 4 participants performed multiple durotomies. Mean time to closure of the durotomy ranged from 490 to 546 seconds in the first and second closures, respectively (P = .66), whereby the median leak rate improved from 14 to 7 (P = .34). There were also demonstrative technical improvements by all. Simulated spinal dura mater repair appears to be a potentially valuable tool in the education of neurosurgery residents. The combination of a didactic and technical assessment appears to be synergistic in terms of educational development.

  7. [Regression trends of neurologic damage in the surgical emergency management of patients with injuries of the cervical vertebrae with spinal cord involvement].

    PubMed

    Kortmann, H R; Wolter, D; Meinecke, F W; Eggers, C

    1986-11-01

    Sixty-five patients with cervical spine injuries and varied neurological deficits were treated operatively. Evaluation revealed an improvement in neurological findings dependent upon the promptness of anatomical reduction in patients with incomplete lesions. The more frequent neurological improvement seen with open reduction and internal fixation as compared with closed reduction was not statistically significant but was felt to justify the additional resources required for internal fixation. In complete lesions, there was no evidence that the time of anatomical reduction was related to improvement in neurological findings.

  8. Image-Guided Internal Fixation of an Oblique Sagittal Split Fracture of C1 Lateral Mass with Motion Preservation: A Technical Report.

    PubMed

    Malcolm, James G; Tan, Lee A; Johnson, Andrew K

    2017-07-20

    A sagittal split fracture of the C1 lateral mass is an unstable subtype of C1 fractures and has a high propensity for developing late deformities and pain with nonoperative management. A primary internal fixation of this type of fracture has been recently described with good clinical outcomes and preservation of motion. We present a modified technique of primary internal fixation using an obliquely inserted C1 lag screw with imaging guidance. We successfully treated a 55-year-old woman with a unilateral C1 oblique sagittal split fracture who failed nonoperative management. Technical nuances are discussed with a review of pertinent literature.

  9. Soft-coupling suspension system for an intradural spinal cord stimulator: Biophysical performance characteristics

    NASA Astrophysics Data System (ADS)

    Oya, H.; Safayi, S.; Jeffery, N. D.; Viljoen, S.; Reddy, C. G.; Dalm, B. D.; Kanwal, J. K.; Gillies, G. T.; Howard, M. A.

    2013-10-01

    We have characterized the mechanical compliance of an improved version of the suspension system used to position the electrode-bearing membrane of an intradural neuromodulator on the dorsal pial surface of the spinal cord. Over the compression span of 5 mm, it exhibited a restoring force of 2.4 μN μm-1 and a mean pressure of 0.5 mm Hg (=66 Pa) on the surface below it, well within the range of normal intrathecal pressures. We have implanted prototype devices employing this suspension and a novel device fixation technique in a chronic ovine model of spinal cord stimulation and found that it maintains stable contact at the electrode-pia interface without lead fracture, as determined by measurement of the inter-contact impedances.

  10. When do anterior external or internal fixators provide additional stability in an unstable (Tile C) pelvic fracture? A biomechanical study.

    PubMed

    Mcdonald, E; Theologis, A A; Horst, P; Kandemir, U; Pekmezci, M

    2015-12-01

    This study aimed at evaluating the additional stability that is provided by anterior external and internal fixators in an unstable pelvic fracture model (OTA 61-C). An unstable pelvic fracture (OTA 61-C) was created in 27 synthetic pelves by making a 5-mm gap through the sacral foramina (posterior injury) and an ipsilateral pubic rami fracture (anterior injury). The posterior injury was fixed with either a single iliosacral (IS) screw, a single trans-iliac, trans-sacral (TS) screw, or two iliosacral screws (S1S2). Two anterior fixation techniques were utilized: external fixation (Ex-Fix) and supra-acetabular external fixation and internal fixation (In-Fix); supra-acetabular pedicle screws connected with a single subcutaneous spinal rod. The specimens were tested using a nondestructive single-leg stance model. Peak-to-peak (P2P) displacement and rotation and conditioning displacement (CD) were calculated. The Ex-Fix group failed in 83.3 % of specimens with concomitant single-level posterior fixation (Total: 15/18-7 of 9 IS fixation, 8 of 9 TS fixation), and 0 % (0/9) of specimens with concomitant two-level (S1S2) posterior fixation. All specimens with the In-Fix survived testing except for two specimens treated with In-Fix combined with IS fixation. Trans-sacral fixation had higher pubic rotation and greater sacral and pubic displacement than S1S2 (p < 0.05). Rotation of the pubis and sacrum was not different between In-Fix constructs combined with single-level IS and TS fixation. In this model of an unstable pelvic fracture (OTA 61-C), anterior fixation with an In-Fix was biomechanically superior to an anterior Ex-Fix in the setting of single-level posterior fixation. There was no biomechanical difference between the In-Fix and Ex-Fix when each was combined with two levels of posterior sacral fixation.

  11. Plate-only open door laminoplasty maintains stable spinal canal expansion with high rates of hinge union and no plate failures.

    PubMed

    Rhee, John M; Register, Bradley; Hamasaki, Takahiko; Franklin, Betty

    2011-01-01

    Prospective clinical series. To evaluate the ability of plate-only laminoplasty to achieve stable laminar arch reconstruction and to determine the rate and time course with which bony healing occurs in such constructs. Reconstruction of a stable laminar arch with sufficient room for the decompressed spinal cord is a desired goal when performing cervical laminoplasty for myelopathy. Traditional forms of laminoplasty fixation, such as sutures, bone struts, and ceramic spacers, may be associated with complications including loss of fixation, dislodgement with neurologic compromise, and premature laminoplasty closure. Plates, in contrast, provide more rigid fixation. Plate-only laminoplasty is gaining popularity as a method of laminoplasty fixation, but there is little data on its effectiveness. Fifty-four patients who underwent open door laminoplasty for cervical myelopathy and had available postoperative computed tomography (CT) scans formed the basis of this study. In all cases, a 4-mm round burr was used to create the hinge at the junction of the lateral mass and lamina by completely removing the dorsal cortex and thinning the ventral cortex until a greenstick deformation of the hinge could be produced. Laminoplasty plates were used as the sole method of fixation. No supplemental bone graft struts were used on the plated side, and the hinge side was not bone grafted. Axial CT scans obtained at 3, 6, and 12 months postoperatively were assessed for plate complications and bony healing of the hinge. No plate failures, dislodgements, or premature closures occurred in any of the levels at any time postoperatively. Computed tomography scan review demonstrated that 55% of levels were healed at 3 months, 77% at 6 months, and 93% at 12 months. At each timepoint, C6 and C7 had the highest hinge healing rates. Laminar screw backout was seen in 5/217 (2.3%) of levels, but was not associated with plate dislodgement, laminoplasty closure, or neurologic consequences, and did not occur in any case in which 2 laminar screws had been placed. Plate-only laminoplasty provided stable reconstruction of an expanded laminar arch with no failures, dislodgements, adverse neurologic consequences, or premature closures in 217 levels. Ninety-three percent of hinges demonstrated radiographic union at 12 months, and even those that did not heal by CT scan criteria maintained patent expansion of the spinal canal without adverse neurologic consequences. Supplemental bone graft does not appear necessary when plated laminoplasty is performed.

  12. Compression and contact area of anterior strut grafts in spinal instrumentation: a biomechanical study.

    PubMed

    Pizanis, Antonius; Holstein, Jörg H; Vossen, Felix; Burkhardt, Markus; Pohlemann, Tim

    2013-08-26

    Anterior bone grafts are used as struts to reconstruct the anterior column of the spine in kyphosis or following injury. An incomplete fusion can lead to later correction losses and compromise further healing. Despite the different stabilizing techniques that have evolved, from posterior or anterior fixating implants to combined anterior/posterior instrumentation, graft pseudarthrosis rates remain an important concern. Furthermore, the need for additional anterior implant fixation is still controversial. In this bench-top study, we focused on the graft-bone interface under various conditions, using two simulated spinal injury models and common surgical fixation techniques to investigate the effect of implant-mediated compression and contact on the anterior graft. Calf spines were stabilised with posterior internal fixators. The wooden blocks as substitutes for strut grafts were impacted using a "pressfit" technique and pressure-sensitive films placed at the interface between the vertebral bone and the graft to record the compression force and the contact area with various stabilization techniques. Compression was achieved either with posterior internal fixator alone or with an additional anterior implant. The importance of concomitant ligament damage was also considered using two simulated injury models: pure compression Magerl/AO fracture type A or rotation/translation fracture type C models. In type A injury models, 1 mm-oversized grafts for impaction grafting provided good compression and fair contact areas that were both markedly increased by the use of additional compressing anterior rods or by shortening the posterior fixator construct. Anterior instrumentation by itself had similar effects. For type C injuries, dramatic differences were observed between the techniques, as there was a net decrease in compression and an inadequate contact on the graft occurred in this model. Under these circumstances, both compression and the contact area on graft could only be maintained at high levels with the use of additional anterior rods. Under experimental conditions, we observed that ligamentous injury following type C fracture has a negative influence on the compression and contact area of anterior interbody bone grafts when only an internal fixator is used for stabilization. Because of the loss of tension banding effects in type C injuries, an additional anterior compressing implant can be beneficial to restore both compression to and contact on the strut graft.

  13. Anterior Z-plate and titanic mesh fixation for acute burst thoracolumbar fracture.

    PubMed

    Xu, Jian-Guang; Zeng, Bing-Fang; Zhou, Wei; Kong, Wei-Qing; Fu, Yi-Shan; Zhao, Bi-Zeng; Zhang, Tao; Lian, Xiao-Feng

    2011-04-01

    A retrospective study. To evaluate the clinical outcome, effectiveness, and security of the surgical management of acute thoracolumbar burst fracture with corpectomy, titanic mesh autograft, and Z-plate fixation by anterior approach. Many surgical methods were adopted to treat acute burst thoracolumbar fracture. But the optimal surgical management remains controversial. A retrospective review of a consecutive series of 48 patients with thoracolumbar burst fracture treated with anterior corpectomy, titanic mesh autograft, and Z-plate internal fixation was carried out. Preoperative clinical and radiographic data of all cases were originally collected. Surgical indications were motor neurologic deficit and thoracolumbar column instability. Twenty-two patients (45.8%) with acute thoracolumbar burst fractures presented with a neurologic deficit. The postoperative recovery of neural function, restoration of anterior cortex collapse, kyphotic angle, and spinal canal compromise were observed. The preoperative kyphotic angle was improved to a mean of 5.6°, radiographic height restored to 95.8% of the adjacent normal levels, and canal compromise was 0%. None of the patients had neurologic deterioration. Mean follow-up time was 32.4 months (range, 24-47 months). All 22 patients with neurologic deficit demonstrated at least one Frankel grade improvement on final observation, with 16 (73%) patients had accomplished complete neurologic recovery. Forty-six (96%) patients reported minimal or no pain at final follow-up observation, and 40 (83%) patients who had been working before injury returned to original work. The authors considered spinal cord decompression with anterior corpectomy and stability reconstruction with titanic mesh autograft and Z-plate fixation at same time in one incision as an effective technique for unstable thoracolumbar burst fracture with and without neurologic deficit.

  14. Clinical Efficacy of Anterior Partial Corpectomy and Titanium Mesh Fusion and Internal Fixation for Treatment of Old Fracture Dislocation of the Lower Cervical Spine

    PubMed Central

    Miao, De-chao; Zhang, Bao-yang; Lei, Tao; Shen, Yong

    2017-01-01

    Background The aim of this study was to analyze the clinical features and to evaluate the efficacy of anterior partial corpectomy and titanium mesh fusion and internal fixation of old fracture dislocation of the lower cervical spine. Material/Methods We retrospectively analyzed the clinical data of 52 patients with old lower cervical fracture and dislocation treated with anterior partial corpectomy and titanium mesh fusion fixation between January 2008 and December 2013, with a mean follow-up period of 4.1 years. There were 35 males and 17 females. Patient radiological data and clinical parameters were recorded and compared before and after the operations. Results The average follow-up was 4.1 years. Intervertebral height and physiological curvature were well-reconstructed for all cases. No loosening or rupturing of titanium plate or screw occurred. The neurological function of the patients with incomplete spinal cord injury was significantly improved, and the function of the nerve roots at the injury level was also improved in patients with complete spinal cord injury. Bone fusion was completed within 6 months to 1 year after surgery. Conclusions Completed decompression, sequence and physiological curvature of the cervical vertebra, immediate and long-term anterior cervical column support, and nerve function restoration can be achieved by using anterior partial corpectomy and titanium mesh fusion and internal fixation to treat old fracture dislocation of the lower cervical spine. For cases with locked facet joints or posterior structures invading the vertebral canal, the combined anterior and posterior approaches should be performed, when necessary, to achieve better results. PMID:29184051

  15. Cauda Equina Syndrome Due to Vigorous Back Massage With Spinal Manipulation in a Patient With Pre-Existing Lumbar Disc Herniation: A Case Report and Literature Review.

    PubMed

    Yang, Si-Dong; Chen, Qian; Ding, Wen-Yuan

    2018-04-01

    Cauda equina syndrome (CES) resulting from acute lumbar disc herniation due to spinal massage is extremely rare. We present a case of CES caused by the acute worsening of a lumbar disc herniation after a vigorous back massage that included spinal manipulation. After vigorous back massage with spinal manipulation performed by a massage therapist, a 38-yr-old male patient experienced CES with severe numbness in both lower limbs, inability to walk due to weakness of bilateral lower limbs, and incontinence of urine and feces. The magnetic resonance imaging and computer tomography scan results showed that the L4-5 disc herniated down into the spinal canal, extensively compressing the ventral dural sac. The patient was successfully treated with an emergency operation including laminectomy, spinal canal decompression, discectomy, interbody fusion, and pedicle screw fixation. The muscle power in both lower limbs of the patient recovered rapidly to support standing only 1 wk later. Moreover, he regained continence of urine and feces. In conclusion, this case brings us novel knowledge that spinal massage or manipulation may worsen pre-existing disc herniation causing CES, and a timely emergency surgery is necessary and effective for treatment of CES-related symptoms.

  16. Histopathologic correlation of magnetic resonance imaging signal patterns in a spinal cord injury model.

    PubMed

    Weirich, S D; Cotler, H B; Narayana, P A; Hazle, J D; Jackson, E F; Coupe, K J; McDonald, C L; Langford, L A; Harris, J H

    1990-07-01

    Magnetic resonance imaging (MRI) provides a noninvasive method of monitoring the pathologic response to spinal cord injury. Specific MR signal intensity patterns appear to correlate with degrees of improvement in the neurologic status in spinal cord injury patients. Histologic correlation of two types of MR signal intensity patterns are confirmed in the current study using a rat animal model. Adult male Sprague-Dawley rats underwent spinal cord trauma at the midthoracic level using a weight-dropping technique. After laminectomy, 5- and 10-gm brass weights were dropped from designated heights onto a 0.1-gm impounder placed on the exposed dura. Animals allowed to regain consciousness demonstrated variable recovery of hind limb paraplegia. Magnetic resonance images were obtained from 2 hours to 1 week after injury using a 2-tesla MRI/spectrometer. Sacrifice under anesthesia was performed by perfusive fixation; spinal columns were excised en bloc, embedded, sectioned, and observed with the compound light microscope. Magnetic resonance axial images obtained during the time sequence after injury demonstrate a distinct correlation between MR signal intensity patterns and the histologic appearance of the spinal cord. Magnetic resonance imaging delineates the pathologic processes resulting from acute spinal cord injury and can be used to differentiate the type of injury and prognosis.

  17. [One-stage total en bloc spondylectomy and reconstruction via a single posterior approach for thoracic vertebral symptomatic hemangioma associated with spinal cord dysfunction].

    PubMed

    Song, Ruo-xian; Zhang, Yong-gang; Zhang, Xue-song; Zheng, Guo-quan; Wang, Yan

    2012-04-01

    To investigate the surgical results of one-stage total en bloc spondylectomy (TES) and reconstruction via a single posterior approach for thoracic symptomatic vertebral hemangioma associated with spinal cord dysfunction and evaluate its curative effect. A total of 9 patients treated with one-stage TES (7 cases) and total vertebrectomy (2 cases) by posterior approach from March 2006 to January 2010 were retrospectively reviewed. The cases included 2 males and 7 females with a median age of 33.6 years (range 14 to 77 years), and with 1 case of Grade A, 3 cases of Grade B, 3 cases of Grade C, 2 cases of Grade D according to Frankel grade system. All patients suffered from moderate to severe pain and neurological deficit with an average symptom duration of 14.4 months (range 3 - 24 months) MRI revealed severe spinal cord compression. The spinal reconstruction was obtained by titanium mesh filled with autograft and posterior internal fixation with rod-screw system. The operation time was 210 minutes on average (180 - 270 minutes) and the average blood loss was 1800 ml (1000 - 5000 ml). The follow-up period lasted from 18 months to 5 years. All cases with preoperative pain relieved after operation. The visual analogue scale pain scores decreased to 1.1 from 8.3 at 3 months after surgery. No disruption of dural mater, cerebrospinal fluid leakage, iatrogenic spinal cord injury and major vessel damage occurred. Up to now, there was no local recurrence in all cases. Significant neurological function improvement was achieved in all patients with one to three grades in Frankel grade system. Fusion of the autograft was well achieved and no internal fixation failure in all patients. One-stage TES and spine reconstruction by a single posterior approach is feasible, safe and effective to this disease. It is favourable in decreasing the hemangioma recurrence and improvement of the neurological function.

  18. Eye Movement Control during Reading: I. The Location of Initial Eye Fixations on Words. Technical Report No. 406.

    ERIC Educational Resources Information Center

    McConkie, G. W.; And Others

    Sixty-six college students read two chapters from a contemporary novel while their eye movements were monitored. The eye movement data were analyzed to identify factors that influence the location of a reader's initial eye fixation on a word. When the data were partitioned according to the location of the prior fixation (i.e., launch site), the…

  19. Preventing Seal Leak During Negative Pressure Wound Therapy Near External Fixators: A Technical Tip.

    PubMed

    Mannino, Brian J; Pullen, Michael W; Gaines, Robert

    2017-03-01

    Negative pressure wound therapy is an effective tool for the treatment of open wounds. Occasionally these wounds are associated with injuries or procedures that require treatment with an external fixator. This article shows how a simple, inexpensive, and commercially available product can be used to prevent loss of suction around external fixator pins within the negative pressure wound treatment area.

  20. 21 CFR 888.3050 - Spinal interlaminal fixation orthosis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... straighten and immobilize the spine to allow bone grafts to unite and fuse the vertebrae together. The device is used primarily in the treatment of scoliosis (a lateral curvature of the spine), but it also may be used in the treatment of fracture or dislocation of the spine, grades 3 and 4 of spondylolisthesis...

  1. 21 CFR 888.3050 - Spinal interlaminal fixation orthosis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... straighten and immobilize the spine to allow bone grafts to unite and fuse the vertebrae together. The device is used primarily in the treatment of scoliosis (a lateral curvature of the spine), but it also may be used in the treatment of fracture or dislocation of the spine, grades 3 and 4 of spondylolisthesis...

  2. Image-Guided Internal Fixation of an Oblique Sagittal Split Fracture of C1 Lateral Mass with Motion Preservation: A Technical Report

    PubMed Central

    Malcolm, James G; Johnson, Andrew K

    2017-01-01

    A sagittal split fracture of the C1 lateral mass is an unstable subtype of C1 fractures and has a high propensity for developing late deformities and pain with nonoperative management. A primary internal fixation of this type of fracture has been recently described with good clinical outcomes and preservation of motion. We present a modified technique of primary internal fixation using an obliquely inserted C1 lag screw with imaging guidance. We successfully treated a 55-year-old woman with a unilateral C1 oblique sagittal split fracture who failed nonoperative management. Technical nuances are discussed with a review of pertinent literature. PMID:28948116

  3. Less invasive reduction and fusion of fresh A2 and A 3 traumatic L 1-L 4 fractures with a novel vertebral body augmentation implant and short pedicle screw fixation and fusion.

    PubMed

    Korovessis, Panagiotis; Vardakastanis, Konstantinos; Repantis, Thomas; Vitsas, Vasilios

    2014-04-01

    The aim of this clinical study was to report on the efficacy in reduction and safety in PMMA leakage of a novel vertebral augmentation technique with PEEK and PMMA, together with pedicle screws in the treatment of fresh vertebral fractures in young adults. Twenty consecutive young adults aged 45 ± 11 years with fresh burst A3/AO or severely compressed A2/AO fractures underwent via a less invasive posterior approach one-staged reduction with a novel augmentation implant and PMMA plus 3-vertebrae pedicle screw fixation and fusion. Radiologic parameters as segmental kyphosis (SKA), anterior (AVBHr) and posterior vertebral body height ratio (PVBHr), spinal canal encroachment (SCE), cement leakage and functional parameters as VAS, SF-36 were measured pre- and post-operatively. Hybrid construct restored AVBHr (P < 0.000), PVBHr (P = 0.02), SKA (P = 0.015), SCE (P = 0.002) without loss of correction at an average follow-up of 17 months. PMMA leakage occurred in 3 patients (3 vertebrae) either anteriorly to the fractured vertebral body or to the adjacent disc, but in no case to the spinal canal. Two pedicle screws were malpositioned (one medially, one laterally to the pedicle at the fracture level) without neurologic sequelae. Solid posterolateral spinal fusion occurred 8-10 months post-operatively. Pre-operative VAS and SF-36 scores improved post-operatively significantly. This study showed that this novel vertebral augmentation technique using PEEK implant and PMMA reduces and stabilizes via less invasive technique A2 and A3 vertebral fractures without loss of correction and leakage to the spinal canal.

  4. Improvement in pain after lumbar surgery in cancer patients with mechanical radiculopathy.

    PubMed

    Moliterno, Jennifer; Veselis, Clinton A; Hershey, Michael A; Lis, Eric; Laufer, Ilya; Bilsky, Mark H

    2014-10-01

    Lumbar metastases can result in spinal instability and mechanical radiculopathy, characterized by radicular pain produced by axial loading. This pain pattern represents a definitive symptom of neoplastic instability and may serve as a reliable indication for surgical stabilization. We examined the results of surgical decompression and fixation in the treatment of mechanical radiculopathy. A retrospective clinical study. An internally maintained spine neurosurgery database was queried between February 2002 and April 2010. Patients were identified and deemed eligible for inclusion in this study based on the presence of all the following: metastatic tumor, lumbar surgery, and lumbar radiculopathy. Visual analog scale (VAS) of pain and Eastern Cooperative Oncology Group (ECOG) status. The Memorial Sloan-Kettering Cancer Center Department of Neurosurgery operative database was queried over an 8-year period to identify all patients with spinal metastases who underwent lumbar surgery. Only patients whose operative indication included mechanical radiculopathy were included. Pre- and postoperative pain was assessed with the VAS of pain, whereas pre- and postoperative performance status was evaluated using the ECOG. Fifty-five patients were included in the cohort. L2 and L3 were the most common levels involved, and most patients underwent multilevel posterior decompression and instrumented fusion. After surgery, 98% of patients reported pain relief. A significant difference between average pre- and postoperative pain scores was found (p<.01). Overall, 41.5% of patients experienced improvement in their ECOG score postoperatively. Mechanical radiculopathy in patients with spinal metastases represents a highly reliable surgical indication. Spinal decompression and fixation is an effective treatment for pain palliation in this patient population. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. [Clinical study on spinal cord decompression combined with traditional Chinese medicine for the treatment of cervical spondylotic myelopathy].

    PubMed

    Yang, Feng; Tan, Ming-Sheng; Yi, Ping; Tang, Xiang-Sheng; Hao, Qing-Ying; Qi, Ying-Na

    2018-01-25

    To compare the clinical effect between spinal card decompression combined with traditional Chinese medicine and simple spinal card decompression for cervical spondylotic myelopathy. From June 2012 to June 2015, 73 patients with cervical spondylotic myelopathy were treated, including 42 males and 31 females, aged from 29 to 73 years old with a mean of 50.9 years old. The patients were divided into the simple operation group (34 cases) and the operation combined with traditional Chinese medicine group(39 cases) according to the idea of themselves. The anterior discectomy or subtotal corpectomy with internal fixation or posterior simple open-door decompression with lateral mass screw fixation were performed in the patients. Among them, 39 cases were treated with traditional Chinese medicine after surgery. The Japanese orthopedic association (JOA) score of spinal cord function, the improvement rate of neural function, the neck dysfunction index (NDI) score and the governor vessel stasis syndrome score were compared between two groups preoperative and postoperative 1 week, 1 month and the final follow-up respectively. The internal fixation and the condition of spinal cord decompression were observed by CT, MRI and X-rays before and after operation. All the operations were successful, no injuries such as dura mater, spinal cord and nerve root were found. All the wounds were healed without infection except one patient had a superficial infection. It was solved after intermittent debridement and anti-infective therapy. Hematoma occurred in 1 case, complicated with spinal cord compression, caused incomplete paralysis, and promptly performed the re-operation to remove the hematoma without any obvious sequelae. All the patients were followed up from 12 to 24 months, (14.6±0.8) months for simple operation group and (13.5±0.7) months for operation combined with traditional Chinese medicine group, and there was no significant difference( P >0.05). The scores of JOA, NDI and the governor's vessel stasis syndrome in simple operation group were 8.31±3.15, 29.91±4.52, 6.58±1.31 before operation, and 10.21±2.58, 18.67±4.31, 8.24±1.18 one week after operation, and 11.38±2.85, 16.11±3.18, 8.91±2.11 one month after operation, and 12.21±3.12, 14.61±3.28, 9.12±1.56 at final follow-up, respectively; and in operation combined with traditional Chinese medicine group were 8.29±3.47, 30.83±4.14, 6.38±1.81before operation, and 10.48±2.39, 17.59±5.14, 8.33±1.57 one week after operation, and 12.14±3.12, 13.14±3.21, 9.55±2.49 one month after operation, and 13.85±3.34, 12.11±2.51, 10.33±1.95 at final follow-up, respectively. Postoperative JOA , NDI, and the governor vessel stasis syndrome score of two groups were significantly higher than preoperativee( P <0.05). There was no significant difference in JOA, NDI, and the governor vessel stasis syndrome score between two groups one week after operation ( P >0.05). The above items in operation combined with traditional Chinese medicine group was better than that of simple operation group one month and final follow-up after operation ( P <0.05). The improvement rate of neural function in simple operation group was (67.59±10.78)%, and in operation combined traditional Chinese medicine group was (66.88±12.15)%, there was no significant difference between two groups( P >0.05). There were no complications such as internal fixation failure or re-dislocation of atlas by postoperative CT, MRI and X-rays examination. Spinal card decompression for the treatment of cervical spondylotic myelopathy can extend the spinal canal, relieve the compression of nerve, achieve the deoppilation of governor vessel, the regulation of qi and blood, the restore of Yangqi, combined with traditional Chinese medicine of activating blood removing stasis, warming yang and activating meridians, reinforcing liver benefiting kidney, which may obtain better clinical effect. Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.

  6. Lumbar vertebral hemangioma mimicking lateral spinal canal stenosis: case report and review of literature.

    PubMed

    Syrimpeis, Vasileios; Vitsas, Vasileios; Korovessis, Panagiotis

    2014-03-01

    Context Hemangiomas are the commonest benign tumors of the spine. Most occur in the thoracolumbar spine and the majority are asymptomatic. Rarely, hemangiomas cause symptoms through epidural expansion of the involved vertebra, resulting in spinal canal stenosis, spontaneous epidural hemorrhage, and pathological burst fracture. Findings We report a rare case of a 73-year-old woman, who had been treated for two months for degenerative neurogenic claudication. On admission, magnetic resonance imaging and computed tomographic scans revealed a hemangioma of the third lumbar vertebra protruding to the epidural space producing lateral spinal stenosis and ipsilateral nerve root compression. The patient underwent successful right hemilaminectomy for decompression of the nerve root, balloon kyphoplasty with poly-methyl methacrylate (PMMA) and pedicle screw segmental stabilization. Postoperative course was uneventful. Conclusion In the elderly, this rare presentation of spinal stenosis due to hemangiomas may be encountered. Decompression and vertebral augmentation by means balloon kyphoplasty with PMMA plus segmental pedicle screw fixation is recommended.

  7. Lumbar vertebral hemangioma mimicking lateral spinal canal stenosis: Case report and review of literature

    PubMed Central

    Syrimpeis, Vasileios; Vitsas, Vasileios; Korovessis, Panagiotis

    2014-01-01

    Context Hemangiomas are the commonest benign tumors of the spine. Most occur in the thoracolumbar spine and the majority are asymptomatic. Rarely, hemangiomas cause symptoms through epidural expansion of the involved vertebra, resulting in spinal canal stenosis, spontaneous epidural hemorrhage, and pathological burst fracture. Findings We report a rare case of a 73-year-old woman, who had been treated for two months for degenerative neurogenic claudication. On admission, magnetic resonance imaging and computed tomographic scans revealed a hemangioma of the third lumbar vertebra protruding to the epidural space producing lateral spinal stenosis and ipsilateral nerve root compression. The patient underwent successful right hemilaminectomy for decompression of the nerve root, balloon kyphoplasty with poly-methyl methacrylate (PMMA) and pedicle screw segmental stabilization. Postoperative course was uneventful. Conclusion In the elderly, this rare presentation of spinal stenosis due to hemangiomas may be encountered. Decompression and vertebral augmentation by means balloon kyphoplasty with PMMA plus segmental pedicle screw fixation is recommended. PMID:24090267

  8. The unreimbursed costs of preventing revision surgery in adult spinal deformity: analysis of cost-effectiveness of proximal junctional failure prevention with ligament augmentation.

    PubMed

    Safaee, Michael M; Dalle Ore, Cecilia L; Zygourakis, Corinna C; Deviren, Vedat; Ames, Christopher P

    2018-05-01

    OBJECTIVE Proximal junctional kyphosis (PJK) is a well-recognized complication of surgery for adult spinal deformity and is characterized by increased kyphosis at the upper instrumented vertebra (UIV). PJK prevention strategies have the potential to decrease morbidity and cost by reducing rates of proximal junctional failure (PJF), which the authors define as radiographic PJK plus clinical sequelae requiring revision surgery. METHODS The authors performed an analysis of 195 consecutive patients with adult spinal deformity. Age, sex, levels fused, upper instrumented vertebra (UIV), use of 3-column osteotomy, pelvic fixation, and mean time to follow-up were collected. The authors also reviewed operative reports to assess for the use of surgical adjuncts targeted toward PJK prevention, including ligament augmentation, hook fixation, and vertebroplasty. The cost of surgery, including direct and total costs, was also assessed at index surgery and revision surgery. Only revision surgery for PJF was included. RESULTS The mean age of the cohort was 64 years (range 25-84 years); 135 (69%) patients were female. The mean number of levels fused was 10 (range 2-18) with the UIV as follows: 2 cervical (1%), 73 upper thoracic (37%), 108 lower thoracic (55%), and 12 lumbar (6%). Ligament augmentation was used in 99 cases (51%), hook fixation in 60 cases (31%), and vertebroplasty in 71 cases (36%). PJF occurred in 18 cases (9%). Univariate analysis found that ligament augmentation and hook fixation were associated with decreased rates of PJF. However, in a multivariate model that also incorporated age, sex, and UIV, only ligament augmentation maintained a significant association with PJF reduction (OR 0.196, 95% CI 0.050-0.774; p = 0.020). Patients with ligament augmentation, compared with those without, had a higher cost of index surgery, but ligament augmentation was overall cost effective and produced significant cost savings. In sensitivity analyses in which we independently varied the reduction in PJF, cost of ligament augmentation, and cost of reoperation by ± 50%, ligament augmentation remained a cost-effective strategy for PJF prevention. CONCLUSIONS Prevention strategies for PJK/PJF are limited, and their cost-effectiveness has yet to be established. The authors present the results of 195 patients with adult spinal deformity and show that ligament augmentation is associated with significant reductions in PJF in both univariate and multivariate analyses, and that this intervention is cost-effective. Future studies will need to determine if these clinical results are reproducible, but for high-risk cases, these data suggest an important role of ligament augmentation for PJF prevention and cost savings.

  9. Quantitation of fixative-induced morphologic and antigenic variation in mouse and human breast cancers

    PubMed Central

    Cardiff, Robert D; Hubbard, Neil E; Engelberg, Jesse A; Munn, Robert J; Miller, Claramae H; Walls, Judith E; Chen, Jane Q; Velásquez-García, Héctor A; Galvez, Jose J; Bell, Katie J; Beckett, Laurel A; Li, Yue-Ju; Borowsky, Alexander D

    2013-01-01

    Quantitative Image Analysis (QIA) of digitized whole slide images for morphometric parameters and immunohistochemistry of breast cancer antigens was used to evaluate the technical reproducibility, biological variability, and intratumoral heterogeneity in three transplantable mouse mammary tumor models of human breast cancer. The relative preservation of structure and immunogenicity of the three mouse models and three human breast cancers was also compared when fixed with representatives of four distinct classes of fixatives. The three mouse mammary tumor cell models were an ER + /PR + model (SSM2), a Her2 + model (NDL), and a triple negative model (MET1). The four breast cancer antigens were ER, PR, Her2, and Ki67. The fixatives included examples of (1) strong cross-linkers, (2) weak cross-linkers, (3) coagulants, and (4) combination fixatives. Each parameter was quantitatively analyzed using modified Aperio Technologies ImageScope algorithms. Careful pre-analytical adjustments to the algorithms were required to provide accurate results. The QIA permitted rigorous statistical analysis of results and grading by rank order. The analyses suggested excellent technical reproducibility and confirmed biological heterogeneity within each tumor. The strong cross-linker fixatives, such as formalin, consistently ranked higher than weak cross-linker, coagulant and combination fixatives in both the morphometric and immunohistochemical parameters. PMID:23399853

  10. SPIRE spinous process stabilization plate: biomechanical evaluation of a novel technology. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2005.

    PubMed

    Wang, Jeremy C; Spenciner, David; Robinson, James C

    2006-02-01

    The authors studied the biomechanical properties of a novel spinous process stabilization plate (CD HORIZON SPIRE Spinal System) and present the results in comparison with those of other posterior fixation methods. Ten functional cadaveric lumbar segments were subjected to nondestructive quasistatic loading forces in 10 different conditions: intact, destabilized (discectomy), fitted with spinous process plate (SPP) alone, with anterior-column support (ACS) alone, ACS with SPP, ACS with posterior translaminar facet screw (PTFS) fixation, ACS with unilateral pedicle screw and rod (UPSR) fixation, ACS with bilateral pedicle screw and rod (BPSR) fixation, UPSR alone, or BPSR alone. Stiffness and range of motion (ROM) data were compared using a repeated-measures, one-way analysis of variance. The construct with greatest mean limitation of flexion-extension ROM was ACS/SPP at 4.14 degrees whereas it was 5.75 degrees for ACS/UPSR fixation, 5.03 degrees for ACS/BPSR fixation, and 10.13 degrees for the intact spine. The SPIRE plate alone also provided greater flexion and extension stiffness, with less ROM than other posterior stabilization options. Fixation with BPSR with or without ACS resulted in the stiffest construct in lateral bending and axial rotation. The SPP and UPSR fixation groups were equivalent in resisting lateral bending and axial rotation forces with or without ACS. The SPIRE plate effectively stabilized the spine, and the test results compare favorably with other fixation techniques that are more time consuming to perform and have greater inherent risks.

  11. [Utility of nickel-titanium shape memory alloys of vertebral body reduction fixator with assisted distraction bar].

    PubMed

    Man, Yi; Zheng, Yue-huan; Cao, Peng; Chen, Bo; Zheng, Tao; Sun, Chang-hui; Lu, Jiong

    2011-06-07

    To test the nickel-titanium (Ni-Ti) shape memory alloys of vertebral body reduction fixator with assisted distraction bar for the treatment of traumatic and osteoporotic vertebral body fracture. A Ni-Ti shape memory alloys of vertebral body reduction fixator with assisted distraction bar was implanted into the compressed fracture specimens through vertebral pedicle with the radiographic monitoring to reduce the collapsed endplate as well as distract the compressed vertebral fracture. Radiographic film and computed tomographic reconstruction technique were employed to evaluate the effects of reduction and distraction. A biomechanic test machine was used to measure the fatigue and the stability of deformation of fixation segments. Relying on the effect of temperature shape memory, such an assembly could basically reduce the collapsed endplate as well as distract the compressed vertebral fracture. And when unsatisfied results of reduction and distraction occurred, its super flexibility could provide additional distraction strength. A Ni-Ti shape memory alloys of vertebral body reduction fixator with assisted distraction bar may provide effective endplate reduction, restore the vertebral height and the immediate biomechanic spinal stability. So the above assembly is indicated for the treatment of traumatic and osteoporotic vertebral body fracture.

  12. [Surgical strategy for upper cervical vertebrae instability through the anterior approach].

    PubMed

    Huang, Wei-bing; Cai, Xian-hua; Chen, Zhuang-hong; Huang, Ji-feng; Liu, Xi-ming; Wei, Shi-jun

    2013-07-01

    To explore the choice and effect of internal fixation in treating upper cervical vertebrae instability through anterior approach. From March 2000 to September 2010,83 patients with upper cervical vertebrae instability were treated with internal fixation through anterior approach. There were 59 males and 24 females with a mean age of 42 years old (ranged, 20 to 68). Among these patients, 36 patients were treated with odontoid screw fixation, 16 patients with C1,2 transarticular screw fixation, 23 patients with C2,3 steel plate fixation, 5 patients with odontoid screw and transarticular screw fixation,2 patients with odontoid screw and C2.3 steel plate fixation, 1 patient with C1,2 transarticular screw and C2,3 steel plate fixation. One patient with completely cervical vertebrae cord injury died of pulmonary infection after C1,2 transarticular screw fixation. Other patients were followed up from 8 to 36 months with an average of 15 months. Upper cervical vertebrae stability were restored without vertebral artery and spinal cord injury. Thirty-six patients were treated with odontoid screw fixation and 5 patients were treated with screw combined with transarticular screw fixation obtained bone union in the dentations without bone graft. Among the 16 patients treated with C1,2 transarticular screw fixation, 13 patients obtained bone union after bone graft; 1 patient died of pulmonary infection after surgery; 1 patient with comminuted odontoid fracture of type II C and atlantoaxial anterior dislocation did not obtain bone union after bone graft,but the fibrous healing was strong enough to maintain the atlantoaixal joint stability; 1 patient with obsolete atlantoaxial anterior dislocation were re-treated with Brooks stainless steel wire fixation and bone graft through posterior approach, and finally obtained bone union. It could obtain satisfactory effects depending on the difference of cervical vertebrae instability to choose the correctly surgical method.

  13. Use of the S-hook for Pelvic Fixation in Rib-Based Treatment of Early-Onset Scoliosis: A Multicenter Study.

    PubMed

    Ramirez, Norman; Flynn, John M; Smith, John T; Vitale, Michael; Sturm, Peter F; DʼAmato, Charles; Samdani, Amer; Machiavelli, Raul; El-Hawary, Ron

    2015-06-01

    Retrospective review. The purpose of this study was to evaluate how several preoperative variables affect the outcome using the rib-to-pelvis S-hook constructs of a rib-based distraction implant (Vertical Expandable Prosthetic Titanium Rib). Rib-to-pelvis fixation with S-hooks is one of the options for distal anchoring of rib-based distraction growing rod construct to control early-onset spinal deformity. Since the initial report, the indications of pelvic fixation with S-hooks have been extended and modified. This is an institutional review board-approved retrospective study of patients who underwent rib-based growing rod system surgery-rib-to-pelvis construct with Dunn-McCarthy S-hook. Data evaluation included history, physical examination, preoperative and postoperative radiographs, surgical variables, and complications. Sixty-five patients were evaluated; 38 were male and 27 were female. Mean age at initial procedure was 71 months. The mean follow-up was 46 months. There was a statistically significant improvement of the immediate postoperative Cobb angle and the last follow-up Cobb angle (P < 0.0001). Fifty percent of the patients (32/65) had S-hook-related complications. The most common complication was sliding of the S-hook out of the iliac crest, followed by infection, neuropathic pain, distal migration of more than 2 cm, fracture of the hook, and bursitis. The complications were related to the preoperative ambulatory status, the use of end-to-end rod connectors, surgical time, and not positioning the hook over the central one-third of the iliac crest at the initial implantation. The use of the S-hook as a pelvic attachment of the rib-based system is indicated in nonambulatory patients with progressive, early-onset scoliosis curve with a lack of adequate anchor at the lumbar spine. Several technical factors should be considered to reduce the complication rate. 3.

  14. A novel anchoring system for use in a nonfusion scoliosis correction device.

    PubMed

    Wessels, Martijn; Homminga, Jasper J; Hekman, Edsko E G; Verkerke, Gijsbertus J

    2014-11-01

    Insertion of a pedicle screw in the mid- and high thoracic regions has a serious risk of facet joint damage. Because flexible implant systems require intact facet joints, we developed an enhanced fixation that is less destructive to spinal structures. The XSFIX is a posterior fixation system that uses cables that are attached to the transverse processes of a vertebra. To determine whether a fixation to the transverse process using the XSFIX is strong enough to withstand the loads applied by the XSLATOR (a novel, highly flexible nonfusion implant system) and thus, whether it is a suitable alternative for pedicle screw fixation. The strength of a novel fixation system using transverse process cables was determined and compared with the strength of a similar fixation using polyaxial pedicle screws on different vertebral levels. Each of the 58 vertebrae, isolated from four adult human cadavers, was instrumented with either a pedicle screw anchor (PSA) system or a prototype of the XSFIX. The PSA consisted of two polyaxial pedicle screws and a 5 mm diameter rod. The XSFIX prototype consisted of two bodies that were fixed to the transverse processes, interconnected with a similar rod. Each fixation system was subjected to a lateral or an axial torque. The PSA demonstrated fixation strength in lateral loading and torsion higher than required for use in the XSLATOR. The XSFIX demonstrated high enough fixation strength (in both lateral loading and torsion), only in the high and midthoracic regions (T10-T12). This experiment showed that the fixation strength of XSFIX is sufficient for use with the XSLATOR only in mid- and high thoracic regions. For the low thoracic and lumbar region, the PSA is a more rigid fixation. Because the performance of the new fixation system appears to be favorable in the high and midthoracic regions, a clinical study is the next challenge. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Treatment of spinal fractures with paraplegia.

    PubMed

    Riska, E B; Myllynen, P

    1981-01-01

    Of 206 patients with vertebral fractures in the thoraco-lumbar spine with spinal cord injuries, an antero-lateral decompression with stabilization of the injured segment of the vertebral column was undertaken in 56 cases. In all these cases there was a compression of the spinal cord from the front. 8 patients made a complete recovery, 31 a good recovery, and 6 were improved. In 8 patients no improvement was noted. 2 patients developed pressure sores later and 1 patient died one year after the operation of uraemia. 22 patients out of 55 got a normal function of the bladder and 25 patients out of 54 a normal function of the anal sphincter. 16 patients out of 17 made a complete or good recovery after removal of a displaced rotated vertebral bony fragment from the spinal canal, and 7 patients out of 9 with wedge shaped fractures. In our clinic today, in cases of vertebral fractures with neural involvement, reduction and internal fixation with Harrington rods and fusion of the injured segment is undertaken as soon as possible, also during the night. If narrowing of the neural canal and compression of the spinal cord are verified, a decompression operation with interbody fusion is undertaken during the next days.

  16. Anterior subcutaneous internal fixation for treatment of unstable pelvic fractures

    PubMed Central

    2014-01-01

    Background Fractures of the pelvic ring including disruption of the posterior elements in high-energy trauma have both high morbidity and mortality rates. For some injury pattern part of the initial resuscitation includes either external fixation or plate fixation to close the pelvic ring and decrease blood loss. In certain situations – especially when associated with abdominal trauma and the need to perform laparotomies – both techniques may put the patient at risk of either pintract or deep plate infections. We describe an operative approach to percutaneously close and stabilize the pelvic ring using spinal implants as an internal fixator and report the results in a small series of patients treated with this technique during the resuscitation phase. Findings Four patients were treated by subcutaneous placement of an internal fixator. Screw fixation was carried out by minimally invasive placement of two supra-acetabular iliac screws. Afterwards, a subcutaneous transfixation rod was inserted and attached to the screws after reduction of the pelvic ring. All patients were allowed to fully weight-bear. No losses of reduction or deep infections occurred. Fracture healing was uneventful in all cases. Conclusion Minimally invasive fixation is an alternative technique to stabilize the pelvic ring. The clinical results illustrate that this technique is able to achieve good results in terms of maintenance of reduction the pelvic ring. Also, abdominal surgeries no longer put the patient at risk of infected pins or plates. PMID:24606833

  17. 21 CFR 888.3060 - Spinal intervertebral body fixation orthosis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... each of a series of vertebral bodies. An eye-type screw is inserted in a hole in the center of each of the plates. A braided cable is threaded through each eye-type screw. The cable is tightened with a tension device and it is fastened or crimped at each eye-type screw. The device is used to apply force to...

  18. 21 CFR 888.3060 - Spinal intervertebral body fixation orthosis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... each of a series of vertebral bodies. An eye-type screw is inserted in a hole in the center of each of the plates. A braided cable is threaded through each eye-type screw. The cable is tightened with a tension device and it is fastened or crimped at each eye-type screw. The device is used to apply force to...

  19. Percutaneous CT and Fluoroscopy-Guided Screw Fixation of Pathological Fractures in the Shoulder Girdle: Technical Report of 3 Cases.

    PubMed

    Garnon, Julien; Koch, Guillaume; Ramamurthy, Nitin; Caudrelier, Jean; Rao, Pramod; Tsoumakidou, Georgia; Cazzato, Roberto Luigi; Gangi, Afshin

    2016-09-01

    To review our initial experience with percutaneous CT and fluoroscopy-guided screw fixation of pathological shoulder-girdle fractures. Between May 2014 and June 2015, three consecutive oncologic patients (mean age 65 years; range 57-75 years) with symptomatic pathological shoulder-girdle fractures unsuitable for surgery and radiotherapy underwent percutaneous image-guided screw fixation. Fractures occurred through metastases (n = 2) or a post-ablation cavity (n = 1). Mechanical properties of osteosynthesis were adjudged superior to stand-alone cementoplasty in each case. Cannulated screws were placed under combined CT and fluoroscopic guidance with complementary radiofrequency ablation or cementoplasty to optimise local palliation and secure screw fixation, respectively, in two cases. Follow-up was undertaken every few weeks until mortality or most recent appointment. Four pathological fractures were treated in three patients (2 acromion, 1 clavicular, 1 coracoid). Mean size of associated lesion was 2.6 cm (range 1-4.5 cm). Technical success was achieved in all cases (100 %), without complications. Good palliation and restoration of mobility were observed in two cases at 2-3 months; one case could not be followed due to early post-procedural oncologic mortality. Percutaneous image-guided shoulder-girdle osteosynthesis appears technically feasible with good short-term efficacy in this complex patient subset. Further studies are warranted to confirm these promising initial results.

  20. Ultrastructural blood-brain barrier alterations and edema formation in acute spinal cord trauma.

    PubMed

    Goodman, J H; Bingham, W G; Hunt, W E

    1976-04-01

    Endothelial changes leading to edema formation are examined in the primate spinal cord (Macaca mulatta) following a lesion created by a 20-gm weight falling 15 cm onto the exposed dura. Intravascular perfusion of a paraformaldehydeglutaraldehyde solution followed by carbon black provides adequate fixation of vascular structures and glial elements. Myelin is poorly preserved. Ultrastructural alterations of the blood-brain barrier consist of loss of integrity of the endothelial tight junctions. Edema caused by vascular disruption and parenchymatous extravasation of intravascular contents is observed along with glial swelling. Interglial gap junctions persist in areas of marked cellular seperation and do not impede the migration of edema fluid.

  1. Surgical technique for balancing posterior spinal fusions to the pelvis using the T square of Tolo.

    PubMed

    Andras, Lindsay; Yamaguchi, Kent T; Skaggs, David L; Tolo, Vernon T

    2012-12-01

    Correcting pelvic obliquity and improving sitting balance in neuromuscular scoliosis often requires fixation to the pelvis. We describe the use of a T square instrument to assist intraoperatively in evaluating the alignment of these curves and achieving balance in the coronal plane. The T square instrument was constructed with a vertical limb perpendicular to 2 horizontal limbs in a T formation. At the conclusion of the instrumentation and preliminary reduction maneuvers, the T square was positioned with the horizontal limbs parallel to the pelvis and the vertical limb in line with the central sacral line. If the spine and pelvis were well balanced, fluoroscopic images demonstrated that the superior aspect of the vertical limb of the T square was crossing the vertebral body of T1. If this was not shown, then some combination of compression, distraction, or a change in the contouring of the rods was performed until this balance was achieved. In this series, we describe case examples in which the T square has been successfully used to aid in achieving balance in the coronal plane. This technique helps to overcome the challenges with positioning and imaging often encountered in managing these long, rigid curves. The T square is a useful adjunct in balancing posterior spinal fusions and evaluating the correction of pelvic obliquity in cases of neuromuscular scoliosis. This novel, yet simple, T square technique can be used for any method of posterior spinal fusion with lumbopelvic fixation to assist in the intraoperative evaluation and achievement of balance in the coronal plane and has become routine at our institution. IV.

  2. Considerations in computer-aided design for inlay cranioplasty: technical note.

    PubMed

    Nout, Erik; Mommaerts, Maurice Y

    2018-03-01

    Cranioplasty is a frequently performed procedure that uses a variety of reconstruction materials and techniques. In this technical note, we present refinements of computer-aided design-computer-aided manufacturing inlay cranioplasty. In an attempt to decrease complications related to polyether-ether-ketone (PEEK) cranioplasty, we gradually made changes to implant design and cranioplasty techniques. These changes include under-contouring of the implant and the use of segmented plates for large defects, microplate fixation for small temporal defects, temporal shell implants to reconstruct the temporalis muscle, and perforations to facilitate the drainage of blood and cerebrospinal fluid and serve as fixation points. From June 2016 to June 2017, 18 patients underwent cranioplasty, and a total of 31 PEEK and titanium implants were inserted. All implants were successful. These changes to implant design and cranioplasty techniques facilitate the insertion and fixation of patient-specific cranial implants and improve esthetic outcomes.

  3. Acrylic Resin Molding Based Head Fixation Technique in Rodents.

    PubMed

    Roh, Mootaek; Lee, Kyungmin; Jang, Il-Sung; Suk, Kyoungho; Lee, Maan-Gee

    2016-01-12

    Head fixation is a technique of immobilizing animal's head by attaching a head-post on the skull for rigid clamping. Traditional head fixation requires surgical attachment of metallic frames on the skull. The attached frames are then clamped to a stationary platform resulting in immobilization of the head. However, metallic frames for head fixation have been technically difficult to design and implement in general laboratory environment. In this study, we provide a novel head fixation method. Using a custom-made head fixation bar, head mounter is constructed during implantation surgery. After the application of acrylic resin for affixing implants such as electrodes and cannula on the skull, additional resins applied on top of that to build a mold matching to the port of the fixation bar. The molded head mounter serves as a guide rails, investigators conveniently fixate the animal's head by inserting the head mounter into the port of the fixation bar. This method could be easily applicable if implantation surgery using dental acrylics is necessary and might be useful for laboratories that cannot easily fabricate CNC machined metal head-posts.

  4. Endogenous stem cell proliferation induced by intravenous hedgehog agonist administration after contusion in the adult rat spinal cord.

    PubMed

    Bambakidis, Nicholas C; Horn, Eric M; Nakaji, Peter; Theodore, Nicholas; Bless, Elizabeth; Dellovade, Tammy; Ma, Chiyuan; Wang, Xukui; Preul, Mark C; Coons, Stephen W; Spetzler, Robert F; Sonntag, Volker K H

    2009-02-01

    Sonic hedgehog (Shh) is a glycoprotein molecule that upregulates the transcription factor Gli1. The Shh protein plays a critical role in the proliferation of endogenous neural precursor cells when directly injected into the spinal cord after a spinal cord injury in adult rodents. Small-molecule agonists of the hedgehog (Hh) pathway were used in an attempt to reproduce these findings through intravenous administration. The expression of Gli1 was measured in rat spinal cord after the intravenous administration of an Hh agonist. Ten adult rats received a moderate contusion and were treated with either an Hh agonist (10 mg/kg, intravenously) or vehicle (5 rodents per group) 1 hour and 4 days after injury. The rats were killed 5 days postinjury. Tissue samples were immediately placed in fixative. Samples were immunohistochemically stained for neural precursor cells, and these cells were counted. Systemic dosing with an Hh agonist significantly upregulated Gli1 expression in the spinal cord (p < 0.005). After spinal contusion, animals treated with the Hh agonist had significantly more nestin-positive neural precursor cells around the rim of the lesion cavity than in vehicle-treated controls (means +/- SDs, 46.9 +/- 12.9 vs 20.9 +/- 8.3 cells/hpf, respectively, p < 0.005). There was no significant difference in the area of white matter injury between the groups. An intravenous Hh agonist at doses that upregulate spinal cord Gli1 transcription also increases the population of neural precursor cells after spinal cord injury in adult rats. These data support previous findings based on injections of Shh protein directly into the spinal cord.

  5. Numerical analysis of multi-level versus short instrumentation for the treatment of thoracolumbar fractures.

    PubMed

    Hübner, André Rafael; Gasparin, Daniel; de Meira Junior, Agenor Dias; Israel, Charles Leonardo; Dambrós, Jean Marcel; Ribeiro, Marcelo; de Freitas Spinelli, Leandro

    2015-07-01

    The research analyses the strength of metallic implants in posterior spinal instrumentation for the treatment of thoracolumbar fractures, considering extended and short fixation techniques on the immediate post-surgical load. Considering that short fixation may bring the advantage of a less invasive surgical procedure to the patient and may also result in lower costs, this evaluation becomes necessary. Three-dimensional modelling of the thoracolumbar spine was initially performed. CT images were captured and converted for analysis with the ANSYS program. Both treatment techniques were analysed for stresses, and strains generated in the immediate postoperative period, when the fracture is still not healed. The maximum stress obtained for long fixation by the theory of Von Mises was 230 MPa, and it was located in the rod area next to the L2 vertebra. The maximum stress obtained for short fixation was 274.24 MPa, and it was located in the pedicle screw on the T12 vertebra. There were no significant differences between the two techniques, since the observed stresses are well below the flow stress of the material, ensuring good safety factor (ranging from 3.5 to 4.1).

  6. Percutaneous CT and Fluoroscopy-Guided Screw Fixation of Pathological Fractures in the Shoulder Girdle: Technical Report of 3 Cases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garnon, Julien, E-mail: juliengarnon@gmail.com; Koch, Guillaume, E-mail: Guillaume.koch@gmail.com; Ramamurthy, Nitin, E-mail: Nitin-ramamurthy@hotmail.com

    ObjectiveTo review our initial experience with percutaneous CT and fluoroscopy-guided screw fixation of pathological shoulder-girdle fractures.Materials and MethodsBetween May 2014 and June 2015, three consecutive oncologic patients (mean age 65 years; range 57–75 years) with symptomatic pathological shoulder-girdle fractures unsuitable for surgery and radiotherapy underwent percutaneous image-guided screw fixation. Fractures occurred through metastases (n = 2) or a post-ablation cavity (n = 1). Mechanical properties of osteosynthesis were adjudged superior to stand-alone cementoplasty in each case. Cannulated screws were placed under combined CT and fluoroscopic guidance with complementary radiofrequency ablation or cementoplasty to optimise local palliation and secure screw fixation, respectively, in two cases. Follow-up wasmore » undertaken every few weeks until mortality or most recent appointment.ResultsFour pathological fractures were treated in three patients (2 acromion, 1 clavicular, 1 coracoid). Mean size of associated lesion was 2.6 cm (range 1–4.5 cm). Technical success was achieved in all cases (100 %), without complications. Good palliation and restoration of mobility were observed in two cases at 2–3 months; one case could not be followed due to early post-procedural oncologic mortality.ConclusionPercutaneous image-guided shoulder-girdle osteosynthesis appears technically feasible with good short-term efficacy in this complex patient subset. Further studies are warranted to confirm these promising initial results.« less

  7. Preliminary report of a sutureless onlay technique for incisional hernia repair using fibrin glue alone for mesh fixation.

    PubMed

    Stoikes, Nathaniel; Webb, David; Powell, Ben; Voeller, Guy

    2013-11-01

    The Rives repair for ventral/incisional (V/I) hernias involves sublay mesh placement requiring retrorectus dissection and transfascial stitches. Chevrel described a repair by onlaying mesh after a unique primary fascial closure. Although Chevrel fixated mesh to the anterior fascia with sutures, he used fibrin glue for fascial closure reinforcement. We describe an onlay technique with mesh fixated to the anterior fascia solely with fibrin glue without suture fixation. From January 2010 to January 2012, 50 patients underwent a V/I hernia onlay technique with fibrin glue mesh fixation. Records were reviewed for technical details, demographics, mesh characteristics, and postoperative outcomes. Primary fascial closure with interrupted permanent suture was done with or without myofascial advancement flaps. Onlay polypropylene mesh was placed providing 8 cm of overlap. Fibrin glue was applied over the prosthesis and subcutaneous drains were placed. Mean age was 62.4 years. Mean body mass index was 30.1 kg/m(2). Average mesh size was 14.5 cm × 19.1 cm. Mean operative time was 144.4 minutes (range, 38 to 316 minutes). Mean discharge was postoperative Day 2.9 (range, 0 to 15 days). Morbidity included eight seromas, one hematoma, and three wound infections. Seventeen patients required components separation. Mean follow-up was 19.5 months with no recurrences. This is the first series describing fibrin glue alone for mesh fixation for V/I hernia repair. It allows for immediate prosthesis fixation to the anterior fascia. Early results are promising. Potential advantages include less operative time, less technical difficulty, and less long-term pain. A prospective trial is needed to evaluate this approach.

  8. Diagnostic Approach to Pediatric Spine Disorders.

    PubMed

    Rossi, Andrea; Martinetti, Carola; Morana, Giovanni; Severino, Mariasavina; Tortora, Domenico

    2016-08-01

    Understanding the developmental features of the pediatric spine and spinal cord, including embryologic steps and subsequent growth of the osteocartilaginous spine and contents is necessary for interpretation of the pathologic events that may affect the pediatric spine. MR imaging plays a crucial role in the diagnostic evaluation of patients suspected of harboring spinal abnormalities, whereas computed tomography and ultrasonography play a more limited, complementary role. This article discusses the embryologic and developmental anatomy features of the spine and spinal cord, together with some technical points and pitfalls, and the most common indications for pediatric spinal MR imaging. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Transarticular fixation with cortical screws combined with dorsal laminectomy and partial discectomy as surgical treatment of degenerative lumbosacral stenosis in 17 dogs: clinical and computed tomography follow-up.

    PubMed

    Golini, Lorenzo; Kircher, Patrick R; Lewis, Fraser I; Steffen, Frank

    2014-05-01

    To describe clinical outcome and technical outcome assessed using computed tomography (CT) in dogs with degenerative lumbosacral stenosis (DLSS) treated by dorsal laminectomy, partial discectomy, and transarticular screw fixation. Retrospective observational case series. Dogs with DLSS (n = 17). Dogs with neurologic and magnetic resonance imaging (MRI) findings compatible with DLSS treated by dorsal laminectomy, partial discectomy and transarticular screw fixation were enrolled. Pre- and postoperative neurologic status was compared. Lumbosacral (LS) angle in extension and misalignment in preoperative MRI were compared with the postoperative CT. Residual mobility of the LS joint after fixation was also evaluated. Status of screws, presence of new bone formation over screw heads/articular facets and presence of adjacent segment disease (ASD) were assessed. Median CT follow-up was 12 months. Clinical improvement was seen in 13 dogs, 2 dogs had intermittent LS pain, and 2 dogs needed revision surgery. In 5 dogs, screws were either pulled out or broken. Reduction of LS angle in extension and misalignment was achieved. Residual mobility of the LS segment was present and ASD was not recognized. Transarticular screw fixation in dogs with DLSS is associated with a considerable number of technical failures and does not result in rigid stabilization; however, this did not significantly adversely influence clinical outcome. © Copyright 2014 by The American College of Veterinary Surgeons.

  10. Research on Process Models of Basic Arithmetic Skills, Technical Report No. 303. Psychology and Education Series - Final Report.

    ERIC Educational Resources Information Center

    Suppes, Patrick; And Others

    This report presents a theory of eye movement that accounts for main features of the stochastic behavior of eye-fixation durations and direction of movement of saccades in the process of solving arithmetic exercises of addition and subtraction. The best-fitting distribution of fixation durations with a relatively simple theoretical justification…

  11. Integrated approach to pain management for a patient with multiple bone metastases of uterine cervical cancer.

    PubMed

    Qin, De-An; Song, Jie-Fu; Song, Li-Ping; Feng, Gui-Sheng

    2018-05-01

    Background Pain management for multiple bone metastases is complex and often requires multidisciplinary treatment. We herein describe patient-centered multidisciplinary pain management for metastatic cancer. A 61-year-old woman with multiple bone metastases of uterine cervical cancer developed intractable low back pain. After external beam radiotherapy failed, we performed lumbar spinal intralesional curettage, pedicle screw fixation, and nerve decompression. However, the neuralgia persisted. We then percutaneously injected epirubicin into the intervertebral foramina under computed tomography guidance for L5 dorsal root ganglion destruction. Osteoplasty was performed under C-arm X-ray guidance; however, the sacrum was mistaken for the ilium, and treatment was ineffective. We administered zoledronic acid and strontium-89. The last resort was outpatient implantation of an epidural bupivacaine-morphine infusion system. A visual analog scale (VAS) was used for pain evaluation. Lumbar spinal intralesional curettage and fixation, epirubicin-induced ganglion destruction, and administration of zoledronic acid and strontium-89 decreased her VAS pain score from 7-8 to 3-4. Radiotherapy and nerve decompression and release were ineffective, as was osteoplasty because of the location error. The epidural infusion system decreased the VAS score from 7-8 to 2-3 and was highly efficient. Conclusions Multidisciplinary integrated treatment for metastatic cancer can be effective.

  12. Content validity of manual spinal palpatory exams - A systematic review

    PubMed Central

    Najm, Wadie I; Seffinger, Michael A; Mishra, Shiraz I; Dickerson, Vivian M; Adams, Alan; Reinsch, Sibylle; Murphy, Linda S; Goodman, Arnold F

    2003-01-01

    Background Many health care professionals use spinal palpatory exams as a primary and well-accepted part of the evaluation of spinal pathology. However, few studies have explored the validity of spinal palpatory exams. To evaluate the status of the current scientific evidence, we conducted a systematic review to assess the content validity of spinal palpatory tests used to identify spinal neuro-musculoskeletal dysfunction. Methods Review of eleven databases and a hand search of peer-reviewed literature, published between 1965–2002, was undertaken. Two blinded reviewers abstracted pertinent data from the retrieved papers, using a specially developed quality-scoring instrument. Five papers met the inclusion/exclusion criteria. Results Three of the five papers included in the review explored the content validity of motion tests. Two of these papers focused on identifying the level of fixation (decreased mobility) and one focused on range of motion. All three studies used a mechanical model as a reference standard. Two of the five papers included in the review explored the validity of pain assessment using the visual analogue scale or the subjects' own report as reference standards. Overall the sensitivity of studies looking at range of motion tests and pain varied greatly. Poor sensitivity was reported for range of motion studies regardless of the examiner's experience. A slightly better sensitivity (82%) was reported in one study that examined cervical pain. Conclusions The lack of acceptable reference standards may have contributed to the weak sensitivity findings. Given the importance of spinal palpatory tests as part of the spinal evaluation and treatment plan, effort is required by all involved disciplines to create well-designed and implemented studies in this area. PMID:12734016

  13. Instrumentation Failure after Partial Corpectomy with Instrumentation of a Metastatic Spine

    PubMed Central

    Park, Sung Bae; Kim, Ki Jeong; Han, Sanghyun; Oh, Sohee; Kim, Chi Heon; Chung, Chun Kee

    2018-01-01

    Objective To identify the perioperative factors associated with instrument failure in patients undergoing a partial corpectomy with instrumentation (PCI) for spinal metastasis. Methods We assessed the one hundred twenty-four patients with who underwent PCI for a metastatic spine from 1987 to 2011. Outcome measure was the risk factor related to implantation failure. The preoperative factors analyzed were age, sex, ambulation, American Spinal Injury Association grade, bone mineral density, use of steroid, primary tumor site, number of vertebrae with metastasis, extra-bone metastasis, preoperative adjuvant chemotherapy, and preoperative spinal radiotherapy. The intraoperative factors were the number of fixed vertebrae, fixation in osteolytic vertebrae, bone grafting, and type of surgical approach. The postoperative factors included postoperative adjuvant chemotherapy and spinal radiotherapy. This study was supported by the National Research Foundation grant funded by government. There were no study-specific biases related to conflicts of interest. Results There were 15 instrumentation failures (15/124, 12.1%). Preoperative ambulatory status and primary tumor site were not significantly related to the development of implant failure. There were no significant associations between insertion of a bone graft into the partial corpectomy site and instrumentation failure. The preoperative and operative factors analyzed were not significantly related to instrumentation failure. In univariable and multivariable analyses, postoperative spinal radiotherapy was the only significant variable related to instrumentation failure (p=0.049 and 0.050, respectively). Conclusion When performing PCI in patients with spinal metastasis followed by postoperative spinal radiotherapy, the surgeon may consider the possibility of instrumentation failure and find other strategies for augmentation than the use of a bone graft for fusion. PMID:29631384

  14. Instrumentation Failure after Partial Corpectomy with Instrumentation of a Metastatic Spine.

    PubMed

    Park, Sung Bae; Kim, Ki Jeong; Han, Sanghyun; Oh, Sohee; Kim, Chi Heon; Chung, Chun Kee

    2018-05-01

    To identify the perioperative factors associated with instrument failure in patients undergoing a partial corpectomy with instrumentation (PCI) for spinal metastasis. We assessed the one hundred twenty-four patients with who underwent PCI for a metastatic spine from 1987 to 2011. Outcome measure was the risk factor related to implantation failure. The preoperative factors analyzed were age, sex, ambulation, American Spinal Injury Association grade, bone mineral density, use of steroid, primary tumor site, number of vertebrae with metastasis, extra-bone metastasis, preoperative adjuvant chemotherapy, and preoperative spinal radiotherapy. The intraoperative factors were the number of fixed vertebrae, fixation in osteolytic vertebrae, bone grafting, and type of surgical approach. The postoperative factors included postoperative adjuvant chemotherapy and spinal radiotherapy. This study was supported by the National Research Foundation grant funded by government. There were no study-specific biases related to conflicts of interest. There were 15 instrumentation failures (15/124, 12.1%). Preoperative ambulatory status and primary tumor site were not significantly related to the development of implant failure. There were no significant associations between insertion of a bone graft into the partial corpectomy site and instrumentation failure. The preoperative and operative factors analyzed were not significantly related to instrumentation failure. In univariable and multivariable analyses, postoperative spinal radiotherapy was the only significant variable related to instrumentation failure ( p =0.049 and 0.050, respectively). When performing PCI in patients with spinal metastasis followed by postoperative spinal radiotherapy, the surgeon may consider the possibility of instrumentation failure and find other strategies for augmentation than the use of a bone graft for fusion.

  15. Marijuana use and mortality following orthopedic surgical procedures.

    PubMed

    Moon, Andrew S; Smith, Walter; Mullen, Sawyer; Ponce, Brent A; McGwin, Gerald; Shah, Ashish; Naranje, Sameer M

    2018-03-20

    The association between marijuana use and surgical procedures is a matter of increasing societal relevance that has not been well studied in the literature. The primary aim of this study is to evaluate the relationship between marijuana use and in-hospital mortality, as well as to assess associated comorbidities in patients undergoing commonly billed orthopedic surgeries. The National Inpatient Sample (NIS) database from 2010 to 2014 was used to determine the odds ratios for the associations between marijuana use and in-hospital mortality, heart failure (HF), stroke, and cardiac disease (CD) in patients undergoing five common orthopedic procedures: hip (THA), knee (TKA), and shoulder arthroplasty (TSA), spinal fusion, and traumatic femur fracture fixation. Of 9,561,963 patients who underwent one of the five selected procedures in the four-year period, 26,416 (0.28%) were identified with a diagnosis of marijuana use disorder. In hip and knee arthroplasty patients, marijuana use was associated with decreased odds of mortality compared to no marijuana use (p<0.0001), and increased odds of HF (p = 0.018), stroke (p = 0.0068), and CD (p = 0.0123). Traumatic femur fixation patients had the highest prevalence of marijuana use (0.70%), which was associated with decreased odds of mortality (p = 0.0483), HF (p = 0.0076), and CD (p = 0.0003). For spinal fusions, marijuana use was associated with increased odds of stroke (p<0.0001) and CD (p<0.0001). Marijuana use in patients undergoing shoulder arthroplasty was associated with decreased odds of mortality (p<0.001) and stroke (p<0.001). In this study, marijuana use was associated with decreased mortality in patients undergoing THA, TKA, TSA and traumatic femur fixation, although the significance of these findings remains unclear. More research is needed to provide insight into these associations in a growing surgical population.

  16. [Adult Grisel Syndrome and Cervical Skull instability. Transnasal endoscopic odontoidectomy and occipito-cervical fusion. Case report and literature review].

    PubMed

    Herrera, Roberto; Rojas, Héctor; Estramian, Ariel; Gómez, Julieta; Ledesma, José Luis; Pablo, José; Pastore, Julián

    2018-01-01

    Craniocervical junction pathology is infrequent in daily neurosurgical practice. In general, most of these lesions are of traumatic or rheumatic origin. Atlantoaxial instability of inflammatory origin (Grisel syndrome) is a rare entity of which only 16 adult cases have been reported in the literature. This pathology is characterized by the development of an osteolytic lesion at the level of the atlantoaxial joint after an infectious event, usually of the upper airways. We present the case of a 76-year-old patient who attended our office for clinical symptoms of spinal instability secondary to an osteolytic lesion, with involvement of C1 and C2. The symptomatology began after an infectious respiratory process. A posterior cervical occiput fixation and an endoscopic transnasal odontoidectomy with anterior decompression were performed. The patient evolved with complete resolution of symptoms. The cultures were negative, and the pathological anatomy study concluded nonspecific inflammatory changes. Until a few years ago, the only option to address this pathology was the transoral pathway with microsurgical technique. Nowadays, endoscopy offers many technical advantages. This is an option to be considered when planning approaches to craniocervical junction.

  17. Avoidance of Wrong-level Thoracic Spine Surgery Using Sterile Spinal Needles: A Technical Report.

    PubMed

    Chin, Kingsley R; Seale, Jason; Cumming, Vanessa

    2017-02-01

    A technical report. The aim of the present study was to present an improvement on localization techniques employed for use in the thoracic spine using sterile spinal needles docked on the transverse process of each vertebra, which can be performed in both percutaneous and open spinal procedures. Wrong-level surgery may have momentous clinical and emotional implications for a patient and surgeon. It is reported that one in every 2 spine surgeons will operate on the wrong level during his or her career. Correctly localizing the specific thoracic level remains a significant challenge during spine surgery. Fluoroscopic anteroposterior and lateral views were obtained starting in the lower lumbar spine, and an 18-G spinal needle was placed in the transverse process of L3 counting up from the sacrum and also at T12. The fluoroscopy was then moved cephalad and counting from the spinal needle at T12, the other spinal needles were placed at the targeted operating thoracic vertebrae. Once this was done, we were able to accurately determine the thoracic levels for surgical intervention. Using this technique, the markers were kept in place even after the incisions were made. This prevented us from losing our location in the thoracic spine. Correctly placed instrumentation was made evident with postoperative imaging. We have described the successful use of a new technique using spinal needles docked against transverse processes to correctly and reliably identify thoracic levels before instrumentation. The technique was reproducible in both open surgeries and for a percutaneous procedure. This technique maintains the correct spinal level during an open procedure. We posit that wrong-level thoracic spine surgery may be preventable.

  18. Hybrid circumferential fixation for degenerative lumbosacral spine disease: posterior lumbar interbody fusion plus universal clamp rod-band instrumentation: a novel technique for lumbosacral fixation.

    PubMed

    Tegos, Stergios; Charitidis, Charalampos; Korovessis, Panagiotis G

    2014-04-01

    Retrospective study on circumferential hybrid instrumentation with posterior lumbar interbody fusion (PLIF) and the novel posterior Universal Clamp (UC) instrumentation. This study evaluated the roentgenographic and clinical outcome after PLIF with PEEK cage augmented with UC posterior sublaminar fixation without posterior fusion. Although UC has been successfully used in scoliosis surgery, to our knowledge, this is the first report on its use in degenerative lumbosacral disease. Rigid pedicle screw lumbosacral fixation is associated with several intraoperative screw-related complications. The use of sublaminar bands and rods combined with PEEK PLIF should increase fusion rate and avoid screw-related complications. From a total of 295 consecutive patients who experienced degenerative lumbosacral disease and received posterior decompression, implantation of PLIF with PEEK cages and semirigid posterior fixation with sublaminar UC bands-rods without posterolateral fusion, 150 patients were eligible for this study with a follow-up of more than 2 years. Interbody fusion rate and global plus segmental sagittal spinal lordosis restoration were recorded pre- and postoperatively. Visual analogue scale and Oswestry Disability Index were used to assess functional outcome. Hybrid instrumentation expanded over 1 to 5 levels. Surgical time ranged from 45 to 225 minutes. Only 12.6% of the patients were transfused. There was no nerve root lesion or deep wound infection. Laminar fracture occurred intraoperatively in one case during band insertion. Interbody fusion was achieved in 94% of the operated segments. Lumbar lordosis improved from -36 ± 9° preoperatively to -53 ± 6° postoperatively. Segmental lordosis improved in L4-L5 segment from -5 ± 3° preoperatively to -12 ± 2° postoperatively and in L5-S1 from -9 ± 4° to -14 ± 2° postoperation. Oswestry Disability Index score improved from 44.9 preoperatively to 2.2 postoperatively (P < 0.001). No patient required further spinal surgery until the final evaluation. UC, a novel semirigid sublaminar posterior instrumentation, combined with wedge-shaped PEEK PLIF corrected both global and segmental sagittal lumbar alignment and achieved fusion rate similar to that historically reported with pedicle screw-PLIF techniques, however, avoiding intraoperative complications associated with the use of pedicle screws.

  19. Effect of cage design, supplemental posterior instrumentation and approach on primary stability of a lumbar interbody fusion - A biomechanical in vitro study.

    PubMed

    Schmoelz, Werner; Sandriesser, Sabrina; Loebl, Oded; Bauer, Marlies; Krappinger, Dietmar

    2017-10-01

    There are various techniques and approaches for lumbar interbody fusion differing in access, cage type and type of supplemental posterior instrumentation. While a transforaminal access usually includes a hemifacetectomy, the facet joint can be preserved with a more lateral extraforaminal access. The supplemental posterior instrumentation required for both fusion techniques is still debated. The purpose of the present study was to compare primary stability of the two accesses for two different cage types with none, unilateral and bilateral supplemental posterior instrumentation. Six monosegmental lumbar functional spinal units (FSUs) were included in each of the two groups, and subjected to a flexibility test. As cages, a newly designed cage was compared to a standard cage in the following states: (a) native, (b) stand-alone cage, (c) bilateral internal fixator, (d) unilateral internal fixator, (e) unilateral facetectomy+bilateral internal fixator, (f) unilateral facetectomy+unilateral internal fixator and (g) unilateral facetectomy with stand-alone cage. For comparison the range of motion was normalized to the native state and the effects of the facetectomy, cage type, and supplemental instrumentation was compared. Within the subject comparison showed a significantly higher flexibility for the unilateral facetectomy in all motion directions (p<0.001). In between subject comparison showed a significant effect of cage type on flexibility in flexion/extension (p=0.002) and lateral bending (p=0.028) but not in axial rotation (p=0.322). The type of supplemental posterior fixation had a significant effect on the flexibility in all motion directions (stand-alone>unilateral fixator>bilateral fixator). Cage design and approach type are affecting the primary stability of lumbar interbody fusion procedures while the type of posterior instrumentation is the most influencing factor. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Symptomatic thoracic spinal cord herniation: case series and technical report.

    PubMed

    Hawasli, Ammar H; Ray, Wilson Z; Wright, Neill M

    2014-09-01

    Idiopathic spinal cord herniation (ISCH) is an uncommon condition located predominantly in the thoracic spine and often associated with a remote history of a major traumatic injury. ISCH has an incompletely described presentation and unknown etiology. There is no consensus on the treatment algorithm and surgical technique, and there are few data on clinical outcomes. In this case series and technical report, we describe the atypical myelopathy presentation, remote history of traumatic injury, radiographic progression, treatment, and outcomes of 5 patients treated at Washington University for symptomatic ISCH. A video showing surgical repair is presented. In contrast to classic compressive myelopathy symptomatology, ISCH patients presented with an atypical myelopathy, characterized by asymmetric motor and sensory deficits and early-onset urinary incontinence. Clinical deterioration correlated with progressive spinal cord displacement and herniation observed on yearly spinal imaging in a patient imaged serially because of multiple sclerosis. Finally, compared with compressive myelopathy in the thoracic spine, surgical treatment of ISCH led to rapid improvement despite a long duration of symptoms. Symptomatic ISCH presents with atypical myelopathy and slow temporal progression and can be successfully managed with surgical repair.

  1. Extended Asymmetrical Pedicle Subtraction Osteotomy for Adult Spinal Deformity: 2-Dimensional Operative Video.

    PubMed

    Buell, Thomas J; Buchholz, Avery L; Quinn, John C; Mullin, Jeffrey P; Garces, Juanita; Mazur, Marcus D; Shaffrey, Mark E; Yen, Chun-Po; Shaffrey, Christopher I; Smith, Justin S

    2018-06-16

    Pedicle subtraction osteotomy (PSO) is an effective technique to correct fixed sagittal malalignment. A variation of this technique, the "trans-discal" or "extended" PSO (Schwab grade IV osteotomy), involves extending the posterior wedge resection of the index vertebra to include the superior adjacent disc for radical discectomy. The posterior wedge may be resected in asymmetric fashion to correct concurrent global coronal malalignment.This video illustrates the technical nuances of an extended asymmetrical lumbar PSO for adult spinal deformity. A 62-yr-old female with multiple prior lumbar fusions presented with worsening back pain and posture. Preoperative scoliosis X-rays demonstrated severe global sagittal and coronal malalignment (sagittal vertical axis [SVA, C7-plumbline] of 13.5 cm, pelvic incidence [PI] of 60°, lumbar lordosis [LL] of 14° [in kyphosis], pelvic tilt [PT] of 61°, thoracic kyphosis [TK] of 18°, and rightward coronal shift of 9.3 cm). The patient gave informed consent to surgery and for use of her imaging for medical publication. Briefly, surgery first involved transpedicular instrumentation from T10 to S1 with bilateral iliac screw fixation, and then T11-12 and T12-L1 Smith-Petersen osteotomies were performed. Next, an extended asymmetrical L4 PSO was performed and a 12° lordotic cage (9 × 14 × 40 mm) was placed at the PSO defect. Rods were placed from T10 to iliac bilaterally, and accessory supplemental rods spanning the PSO were attached. Postoperative scoliosis X-rays demonstrated improved alignment: SVA 5.5 cm, PI 60°, LL 55°, PT 36°, TK 37°, and 3.7 cm of rightward coronal shift. The patient had uneventful recovery.

  2. Sacroiliac joint dysfunction.

    PubMed

    Ilaslan, Hakan; Arslan, Ahmet; Koç, Omer Nadir; Dalkiliç, Turker; Naderi, Sait

    2010-07-01

    Sacroiliac joint dysfunction is a disorder presenting with low back and groin pain. It should be taken into consideration during the preoperative differential diagnosis of lumbar disc herniation, lumbar spinal stenosis and facet syndrome. Four cases with sacroiliac dysfunction are presented. The clinical and radiological signs supported the evidence of sacroiliac dysfunction, and exact diagnosis was made after positive response to sacroiliac joint block. A percutaneous sacroiliac fixation provided pain relief in all cases. The mean VAS scores reduced from 8.2 to 2.2. It is concluded that sacroiliac joint dysfunction diagnosis requires a careful physical examination of the sacroiliac joints in all cases with low back and groin pain. The diagnosis is made based on positive response to the sacroiliac block. Sacroiliac fixation was found to be effective in carefully selected cases.

  3. Biomechanical in vitro - stability testing on human specimens of a locking plate system against conventional screw fixation of a proximal first metatarsal lateral displacement osteotomy.

    PubMed

    Arnold, Heino; Stukenborg-Colsman, Christina; Hurschler, Christof; Seehaus, Frank; Bobrowitsch, Evgenij; Waizy, Hazibullah

    2012-01-01

    The aim of this study was to examine resistance to angulation and displacement of the internal fixation of a proximal first metatarsal lateral displacement osteotomy, using a locking plate system compared with a conventional crossed screw fixation. Seven anatomical human specimens were tested. Each specimen was tested with a locking screw plate as well as a crossed cancellous srew fixation. The statistical analysis was performed by the Friedman test. The level of significance was p = 0.05. We found larger stability about all three axes of movement analyzed for the PLATE than the crossed screws osteosynthesis (CSO). The Friedman test showed statistical significance at a level of p = 0.05 for all groups and both translational and rotational movements. The results of our study confirm that the fixation of the lateral proximal first metatarsal displacement osteotomy with a locking plate fixation is a technically simple procedure of superior stability.

  4. Biomechanical In Vitro - Stability Testing on Human Specimens of a Locking Plate System Against Conventional Screw Fixation of a Proximal First Metatarsal Lateral Displacement Osteotomy

    PubMed Central

    Arnold, Heino; Stukenborg-Colsman, Christina; Hurschler, Christof; Seehaus, Frank; Bobrowitsch, Evgenij; Waizy, Hazibullah

    2012-01-01

    Introduction: The aim of this study was to examine resistance to angulation and displacement of the internal fixation of a proximal first metatarsal lateral displacement osteotomy, using a locking plate system compared with a conventional crossed screw fixation. Materials and Methodology: Seven anatomical human specimens were tested. Each specimen was tested with a locking screw plate as well as a crossed cancellous srew fixation. The statistical analysis was performed by the Friedman test. The level of significance was p = 0.05. Results: We found larger stability about all three axes of movement analyzed for the PLATE than the crossed screws osteosynthesis (CSO). The Friedman test showed statistical significance at a level of p = 0.05 for all groups and both translational and rotational movements. Conclusion: The results of our study confirm that the fixation of the lateral proximal first metatarsal displacement osteotomy with a locking plate fixation is a technically simple procedure of superior stability. PMID:22675409

  5. Aspects of internal fixation of fractures in porotic bone. Principles, technologies and procedures using locked plate screws.

    PubMed

    Perren, S M; Linke, B; Schwieger, K; Wahl, D; Schneider, E

    2005-01-01

    Fractures of the bones of elderly people occur more often and have a more important effect because of a generally diminished ability to coordinate stance and walking. These fractures occur at a lower level of load because of lack of strength of the porotic bone. Prompt recovery of skeletal support function is essential to avoid respiratory and circulatory complications in the elderly. To prevent elderly people from the risks of being bedridden, demanding internal fixation of fractures is required. The weak porotic bone and the high level of uncontrolled loading after internal fixation pose complex problems. A combination of several technical elements of design, application and aftercare in internal fixation are proposed. Internal fixators with locked screws improve the biology and the mechanics of internal fixation. When such fixators are used as elevated splints they may stimulate early callus formation because of their flexibility, the limit of flexibility being set by the demands of resistance and function of the limb. Our own studies of triangulation of locked screws have demonstrated their beneficial effects and unexpected limitations.

  6. Matrix Metalloproteinases as a Therapeutic Target to Improve Neurologic Recovery After Spinal Cord Injury

    DTIC Science & Technology

    2015-12-01

    aberrant remodeling of the bladder wall, which could contribute to increased weight of this structure and reduced voiding. We next evaluated the...moderate levels of SCI show both neurological and urological recovery. Task 4. Analysis of lesion epicenter and serotonergic fiber tracks caudal to a...SCI in mice. 4a. Perfuse animals with fixative, remove the cords, and stain with Eriochrome cyanine or immunostain for serotonergic fiber tracks

  7. A minimally invasive approach to long-term head fixation in behaving nonhuman primates

    PubMed Central

    Davis, T.S.; Torab, K.; House, P.; Greger, B.

    2009-01-01

    We have designed a device for long-term head fixation for use in behaving nonhuman primates that is robust yet minimally invasive and simple to use. This device is a modified version of the halo system that is used in humans for cervical traction and stabilization after spinal column injuries. This device consists of an aluminum halo with four titanium skull pins offset from the halo by aluminum posts. The titanium pins insert onto small segments of cranially reinforcing titanium plate, which are attached to the skull with titanium cortex screws. The surgery involves four scalp incisions, placement of the reinforcing plates, insertion of the pins for attachment of the halo, and incision closure. After the halo is attached, the animal’s head can be fixed to a primate chair using a custom-built attachment arm that provides three degrees of adjustability for proper positioning during behavioral tasks. We have installed this device on two Macaque monkeys weighing seven and ten kilograms. The halos have been in place on these animals for up to eight months without signs of discomfort or loss of fixation. Using this method of head fixation, we have been able to track the animals’ eye positions with an accuracy of less than two visual degrees while they perform behavioral tasks. PMID:19394360

  8. CT-Guided Transfacet Pedicle Screw Fixation in Facet Joint Syndrome: A Novel Approach

    PubMed Central

    Manfré, Luigi

    2014-01-01

    Summary Axial microinstability secondary to disc degeneration and consequent chronic facet joint syndrome (CFJS) is a well-known pathological entity, usually responsible for low back pain (LBP). Although posterior lumbar fixation (PIF) has been widely used for lumbar spine instability and LBP, complications related to wrong screw introduction, perineural scars and extensive muscle dissection leading to muscle dysfunction have been described. Radiofrequency ablation (RFA) of facet joints zygapophyseal nerves conventionally used for pain treatment fails in approximately 21% of patients. We investigated a “covert-surgery” minimal invasive technique to treat local spinal instability and LBP, using a novel fully CT-guided approach in patients with axial instability complicated by CFJS resistant to radioablation, by introducing direct fully or partially threaded transfacet screws (transfacet fixation - TFF), to acquire solid arthrodesis, reducing instability and LBP. The CT-guided procedure was well tolerated by all patients in simple analogue sedation, and mean operative time was approximately 45 minutes. All eight patients treated underwent clinical and CT study follow-up at two months, revealing LBP disappearance in six patients, and a significant reduction of lumbar pain in two. In conclusion, CT-guided TFF is a fast and safe technique when facet posterior fixation is needed. PMID:25363265

  9. The Free-Hand Technique for S2-Alar-Iliac Screw Placement: A Safe and Effective Method for Sacropelvic Fixation in Adult Spinal Deformity.

    PubMed

    Shillingford, Jamal N; Laratta, Joseph L; Tan, Lee A; Sarpong, Nana O; Lin, James D; Fischer, Charla R; Lehman, Ronald A; Kim, Yongjung J; Lenke, Lawrence G

    2018-02-21

    Spinopelvic fixation is an integral part of achieving solid fusion across the lumbosacral junction, especially in deformity procedures requiring substantial correction or long-segment constructs. Traditional S2-alar-iliac (S2AI) screw-placement techniques utilize fluoroscopy, increasing operative time and radiation exposure to the patient and surgeon. We describe a novel free-hand technique for S2AI screw placement in patients with adult spinal deformity. We reviewed the records of 45 consecutive patients who underwent spinopelvic fixation performed with use of S2AI screws by the senior surgeon and various fellows or residents over a 12-month period (2015 to 2016). In each case, the S2AI screws were placed utilizing a free-hand technique without fluoroscopic or image guidance. Screw position and accuracy were assessed by intraoperative O-arm imaging and analyzed using 3-dimensional interactive manipulation of computed tomography images. A total of 100 screws were placed, 51 by the senior surgeon and 49 by trainees. The mean patient age was 57.4 ± 12.7 years at the time of surgery; 37 (82.2%) of the patients were female. Preoperative diagnoses included adult idiopathic scoliosis (n = 19), adult degenerative scoliosis (n = 15), flatback syndrome (n = 2), fixed sagittal imbalance (n = 6), and distal junctional kyphosis (n = 3). Five (5%) of the screws were placed with moderate to severe cortical breaches, all of which perforated the pelvis posteriorly, with no clinically notable neurovascular or visceral complications. The breach rate did not differ significantly between the senior surgeon and trainees. The free-hand technique for S2AI screw placement, when performed in a standardized manner, was demonstrated to be safe and reliable in constructs requiring spinopelvic fixation. The accuracy of screw placement relies on visible and palpable anatomic landmarks that obviate the need for intraoperative fluoroscopy or image guidance, potentially reducing operative time and radiation exposure. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  10. Biomechanical Evaluation of the CD HORIZON Spire Z Spinal System With Pedicle and Facet Fixation.

    PubMed

    Godzik, Jakub; Kalb, Samuel; Martinez-Del-Campo, Eduardo; Newcomb, Anna G U S; Singh, Vaneet; Walker, Corey T; Chang, Steve W; Kelly, Brian P; Crawford, Neil R

    2016-08-01

    Human cadaveric biomechanical study. The aim of this study was to evaluate the biomechanics of lumbar motion segments instrumented with the CD HORIZON Spire Z plate system (Spire Z), a posterior supplemental fixation spinous process plate, alone and with additional fixation systems. Plates and pedicle screw/rod and facet screw implants are adjuncts to fusion. The plate limits motion, improving segmental stability and the fusion microenvironment. However, the degree to which the plate contributes to overall stability when used alone or in conjunction with additional instrumentation has not been described. Standard nondestructive flexibility tests were performed in 7 L2-L5 human cadaveric spines. Spinal stability was determined as mean range of motion (ROM) in flexion/extension, lateral bending, and axial rotation. Paired comparisons were made between five conditions: (1) intact/control; (2) Spire Z; (3) Spire Z with unilateral pedicle screw/rod system (Spire Z+UPS); (4) Spire Z with unilateral facet screw system (Spire Z+UFS); and (5) Spire Z with bilateral facet screw system (Spire Z+BFS). Stiffness and ROM data were compared using one-way analysis of variance, followed by repeated-measures Holm-Šidák tests. Spire Z was most effective in limiting flexion (20% of normal) and extension (24% of normal), but less effective in reducing lateral bending and axial rotation. In lateral bending, Spire Z+BFS and Spire Z+UPS constructs were not significantly different and demonstrated greater ROM reduction compared with Spire Z+UFS and Spire Z (P < 0.001). Spire Z+BFS demonstrated greatest stiffness in axial rotation compared with Spire Z+UPS (P = 0.025), Spire Z+UFS (P = 0.001), and Spire Z (P < 0.001). Spire Z+UPS was not significantly different from Spire Z+UFS (P = 0.21), and superior to Spire Z (P = 0.013). The Spire Z spinous process plate provides excellent immediate fixation, particularly for flexion and extension. While the hybrid Spire Z+BFS screw construct afforded the greatest stability, Spire Z+UPS demonstrated considerable promise. N/A.

  11. Comparative Study Between Cobalt Chrome and Titanium Alloy Rods for Multilevel Spinal Fusion: Proximal Junctional Kyphosis More Frequently Occurred in Patients Having Cobalt Chrome Rods.

    PubMed

    Han, Sanghyun; Hyun, Seung-Jae; Kim, Ki-Jeong; Jahng, Tae-Ahn; Kim, Hyun-Jib

    2017-07-01

    The use of titanium alloy (Ti) rods is frequently associated with rod fracture after spinal fixation. To address this issue, cobalt chrome (CoCr) rods, which are advantageous because of their greater strength and resistance to fatigue relative to Ti rods, have been introduced. The purpose of the present study was to compare radiographic outcomes after the use of Ti versus CoCr rods in a matched cohort of patients undergoing posterior spinal fusion for treatment of spinal instability. We retrospectively reviewed data from patients who had undergone spinal fusion involving more than 3 levels at a single institution between 2004 and 2015. Patients were matched for age, diagnosis, 3-column osteotomy, levels fused, and T score. Fifty patients with Ti rods were identified and appropriately matched to 50 consecutive patients with CoCr rods. The distributions of age at surgery, sex, diagnosis, 3-column osteotomy, levels fused, number of patients with previous surgical procedures, and T score did not significantly differ between the 2 groups. However, there were significant differences in length of follow-up (CoCr, 25.0 vs. Ti, 28.5 months; P < 0.001), fusion rate (CoCr, 45 [90%] vs. Ti, 33 [66%]; P = 0.004), occurrence of rod breakage (CoCr, 0 vs. T, 8 [16%]; P = 0.006), and junctional kyphosis (CoCr, 24 [46%] vs. Ti, 9 [18%]; P = 0.003). Our findings indicate that the use of CoCr rods is effective in ensuring stability of the posterior spinal construct and accomplishment of spinal fusion. Furthermore, our results indicate that junctional kyphosis may occur more frequently in CoCr systems than in Ti systems. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Carrier testing for spinal muscular atrophy

    PubMed Central

    Gitlin, Jonathan M.; Fischbeck, Kenneth; Crawford, Thomas O.; Cwik, Valerie; Fleischman, Alan; Gonye, Karla; Heine, Deborah; Hobby, Kenneth; Kaufmann, Petra; Keiles, Steven; MacKenzie, Alex; Musci, Thomas; Prior, Thomas; Lloyd-Puryear, Michele; Sugarman, Elaine A.; Terry, Sharon F.; Urv, Tiina; Wang, Ching; Watson, Michael; Yaron, Yuval; Frosst, Phyllis; Howell, R. Rodney

    2014-01-01

    Spinal muscular atrophy is the most common fatal hereditary disease among newborns and infants. There is as yet no effective treatment. Although a carrier test is available, currently there is disagreement among professional medical societies who proffer standards of care as to whether or not carrier screening for spinal muscular atrophy should be offered as part of routine reproductive care. This leaves health care providers without clear guidance. In fall 2009, a meeting was held by National Institutes of Health to examine the scientific basis for spinal muscular atrophy carrier screening and to consider the issues that accompany such screening. In this article, the meeting participants summarize the discussions and conclude that pan-ethnic carrier screening for spinal muscular atrophy is technically feasible and that the specific study of implementing a spinal muscular atrophy carrier screening program raises broader issues about determining the scope and specifics of carrier screening in general. PMID:20808230

  13. [A robotic system for gait re-education in patients with an incomplete spinal cord injury].

    PubMed

    Esclarín-De Ruz, A; Alcobendas-Maestro, M; Casado-López, R; Muñoz-Gonzalez, A; Florido-Sánchez, M A; González-Valdizán, E

    A spinal cord injury involves the loss or alteration of motor patterns in walking, the recovery of which depends partly on the rearrangement of the preserved neural circuits. AIM. To evaluate the changes that take place in the gait of patients with incomplete spinal cord injuries who were treated with a robotic walking system in association with conventional therapy. The study conducted was an open-label, prospective, descriptive trial with statistical inference in patients with C2-L3 spinal cord injuries that were classified as degrees C and D according to the American Spinal Injury Association (ASIA) scale. The variables that were analysed on the first and the last day of the study were: number of walkers, 10-m gait test, the Walking Index for Spinal Cord Injury scale revision, technical aids, muscle balance in the lower limbs, locomotor subscale of the measure of functional independence, modified Ashworth scale for spasticity and the visual analogue scale for pain. At the end, data were recorded from the impression of change scale. The analysis was conducted by means of Student's t, chi squared and Pearson's correlation; p < or = 0.05. Forty-five patients, with a mean age of 44 +/- 14.3 years, finished the study; 76% were males, injury was caused by trauma in 58% of cases, and the time of progression was 139 +/- 70 days. Statistically significant increases were observed in the number of subjects capable of walking, walking speed, less need for technical aids, strength in the lower limbs and independence in activities of daily living. Treatment using the robotic system in association with conventional therapy improves walking capacity in patients with incomplete spinal cord injuries.

  14. Morphometric analysis of cervical spinal canal diameter, transverse foramen, and pedicle width using computed tomography in Indian population.

    PubMed

    Sureka, Binit; Mittal, Aliza; Mittal, Mahesh K; Agarwal, Kanhaiya; Sinha, Mukul; Thukral, Brij Bhushan

    2018-01-01

    Accurate and detailed measurements of spinal canal diameter (SCD) and transverse foraminal morphometry are essential for understanding spinal column-related diseases and for surgical planning, especially for transpedicular screw fixation. This is especially because lateral cervical radiographs do not provide accurate measurements. This study was conducted to measure the dimensions of the transverse foramen sagittal and transverse diameters (SFD, TFD), SCD, and the distance of spinal canal from the transverse foramina (dSC-TF) at C1-C7 level in the Indian population. The study population comprised 84 male and 42 female subjects. The mean age of the study group was 44.63 years (range, 19-81 years). A retrospective study was conducted, and data were collected and analyzed for patients who underwent cervical spine computed tomography (CT) imaging for various reasons. One hundred and twenty-six patients were included in the study. Detailed readings were taken at all levels from C1-C7 for SCD, SFD, TFD, and dSc-TF. Values for male and female subjects were separately calculated and compared. For both the groups, the widest SCD were measured at the C1 level and the narrowest SCD at the C4 level. The narrowest SFD was measured at C7 for both male and female subjects on the right and left sides. The widest SFD was measured at C1 both for male and female subjects on the right and left side. The narrowest TFD on the left side was measured at C7 for male and at C1 for female subjects. The narrowest mean distance of dSC-TF was found to be at C4 for both male and female subjects on both left and right side. The computed tomographic (CT) imaging is better than conventional radiographs for the preoperative evaluation of cervical spine and for better understanding cervical spine morphometry. Care must be taken during transpedicular screw fixation, especially in female subjects, more so at the C2, C4, and C6 levels due to a decrease in the distance of dSC-TF.

  15. Symptomatic Thoracic Spinal Cord Herniation: Case Series and Technical Report

    PubMed Central

    Hawasli, Ammar H.; Ray, Wilson Z.; Wright, Neill M.

    2014-01-01

    Background and Importance Idiopathic spinal cord herniation (ISCH) is an uncommon condition located predominantly in the thoracic spine and often associated with a remote history of a major traumatic injury. ISCH has an incompletely described presentation and unknown etiology. There is no consensus on treatment algorithm and surgical technique, and there is little data on clinical outcomes. Clinical Presentation In this case series and technical report, we describe the atypical myelopathy presentation, remote history of traumatic injury, radiographic progression, treatment, and outcomes of 5 patients treated at Washington University for symptomatic ISCH. A video showing surgical repair is presented. In contrast to classic compressive myelopathy symptomology, ISCH patients presented with an atypical myelopathy, characterized by asymmetric motor and sensory deficits and early-onset urinary incontinence. Clinical deterioration correlated with progressive spinal cord displacement and herniation observed on yearly spinal imaging in a patient imaged serially due to multiple sclerosis. Finally compared to compressive myelopathy in the thoracic spine, surgical treatment of ISH led to rapid improvement despite long duration of symptoms. Conclusion Symptomatic ISCH presents with atypical myelopathy and slow temporal progression and can be successfully managed with surgical repair. PMID:24871148

  16. Virtual reality-based simulators for spine surgery: a systematic review.

    PubMed

    Pfandler, Michael; Lazarovici, Marc; Stefan, Philipp; Wucherer, Patrick; Weigl, Matthias

    2017-09-01

    Virtual reality (VR)-based simulators offer numerous benefits and are very useful in assessing and training surgical skills. Virtual reality-based simulators are standard in some surgical subspecialties, but their actual use in spinal surgery remains unclear. Currently, only technical reviews of VR-based simulators are available for spinal surgery. Thus, we performed a systematic review that examined the existing research on VR-based simulators in spinal procedures. We also assessed the quality of current studies evaluating VR-based training in spinal surgery. Moreover, we wanted to provide a guide for future studies evaluating VR-based simulators in this field. This is a systematic review of the current scientific literature regarding VR-based simulation in spinal surgery. Five data sources were systematically searched to identify relevant peer-reviewed articles regarding virtual, mixed, or augmented reality-based simulators in spinal surgery. A qualitative data synthesis was performed with particular attention to evaluation approaches and outcomes. Additionally, all included studies were appraised for their quality using the Medical Education Research Study Quality Instrument (MERSQI) tool. The initial review identified 476 abstracts and 63 full texts were then assessed by two reviewers. Finally, 19 studies that examined simulators for the following procedures were selected: pedicle screw placement, vertebroplasty, posterior cervical laminectomy and foraminotomy, lumbar puncture, facet joint injection, and spinal needle insertion and placement. These studies had a low-to-medium methodological quality with a MERSQI mean score of 11.47 out of 18 (standard deviation=1.81). This review described the current state and applications of VR-based simulator training and assessment approaches in spinal procedures. Limitations, strengths, and future advancements of VR-based simulators for training and assessment in spinal surgery were explored. Higher-quality studies with patient-related outcome measures are needed. To establish further adaptation of VR-based simulators in spinal surgery, future evaluations need to improve the study quality, apply long-term study designs, and examine non-technical skills, as well as multidisciplinary team training. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Traumatic Posterior Atlantoaxial Dislocation Without Associated Fracture but With Neurological Deficit

    PubMed Central

    Xu, Yong; Li, Feng; Guan, Hanfeng; Xiong, Wei

    2015-01-01

    Abstract Posterior atlantoaxial dislocation without odontoid fracture is extremely rare and often results in fatal spinal cord injury. According to the reported literature, all cases presented mild or no neurologic deficit, with no definite relation to upper spinal cord injury. Little is reported about traumatic posterior atlantoaxial dislocation, with incomplete quadriplegia associated with a spinal cord injury. We present a case of posterior atlantoaxial dislocation without associated fracture, but with quadriplegia, and accompanying epidural hematoma and subarachnoid hemorrhage. The patient underwent gentle traction in the neutral position until repeated cranial computed tomography revealed no progression of the epidural hematoma. Thereafter, the atlantoaxial dislocation was reduced by using partial odontoidectomy via a video-assisted transcervical approach and maintained with posterior polyaxial screw-rod constructs and an autograft. Neurological status improved immediately after surgery, and the patient recovered completely after 1 year. Posterior fusion followed by closed reduction is the superior strategy for posterior atlantoaxial dislocation without odontoid fracture, according to literature. But for cases with severe neurological deficit, open reduction may be the safest choice to avoid the lethal complication of overdistraction of the spinal cord. Also, open reduction and posterior srew-rod fixation are safe and convenient strategies in dealing with traumatic posterior atlantoaxial dislocation patients with neurological deficit. PMID:26512572

  18. Metastatic spinal cord compression from basal cell carcinoma of the skin treated with surgical decompression and vismodegib: case report and review of Hedgehog signalling pathway inhibition in advanced basal cell carcinoma.

    PubMed

    McGrane, J; Carswell, S; Talbot, T

    2017-01-01

    We report a case of a 66-year-old man with locally advanced and metastatic basal cell carcinoma (BCC) causing spinal cord compression, which was treated with spinal surgery and subsequent vismodegib. The patient presented with a large fungating chest wall lesion and a metastasis in T8 that was causing cord compression. He had neurosurgical decompression of the T8 lesion and fixation of the spine. Punch biopsy from the fungating chest wall lesion showed a BCC with some malignant squamous differentiation (basosquamous). Histopathological examination of the metastatic lesion in T8 at the time of surgical decompression identified features identical to the punch biopsy. The patient was referred to the oncology clinic for adjuvant treatment. In light of his metastatic disease and the large area over his chest wall that could not fully be covered by radiotherapy, he was treated with the novel oral Hedgehog signalling pathway (HHSP) inhibitor vismodegib, which led to marked improvement. © 2016 British Association of Dermatologists.

  19. Rod Migration Into the Spinal Canal After Posterior Instrumented Fusion Causing Late-Onset Neurological Symptoms.

    PubMed

    Canavese, Federico; Dmitriev, Petru; Deslandes, Jacques; Samba, Antoine; Dimeglio, Alain; Mansour, Mounira; Rousset, Marie; Dubousset, Jean

    2017-01-01

    Rod migration into the spinal canal after posterior instrumented fusion is a rare complication causing late-onset neurological symptoms. The purpose of the present study is to report a case of a 13-year-old boy with spastic cerebral palsy and related neuromuscular kyphoscoliosis who developed late-onset neurological deterioration secondary to progressive implant migration into the spinal canal over a 5-year period. A decision was made to remove both rods to achieve decompression. Intraoperative findings were consistent with information gained from preoperative imaging. The rods were found to have an intracanal trajectory at T9-T10 for the right rod and T12-L2 for the left rod. The cause of implant migration, with progressive laminar erosion slow enough to generate a solid mass behind, was progressive kyphosis in a skeletally immature patient with neuromuscular compromise. Fixation type, early surgery, and spasticity management contributed significantly to the presenting condition. Mechanical factors and timing of surgery played a decisive role in this particular presentation. Level IV--Case report and review of the literature.

  20. Cervical osteotomy in ankylosing spondylitis: evaluation of new developments.

    PubMed

    Langeloo, Danielle D; Journee, Henricus L; Pavlov, Paul W; de Kleuver, Marinus

    2006-04-01

    Cervical osteotomy can be performed on patients with cervical kyphosis due to ankylosing spondylitis. This study reviews the role of two new developments in cervical osteotomy surgery: internal fixation and transcranial electrical stimulated motor evoked potential monitoring (TES-MEP). From 1999 to 2004, 16 patients underwent a C7-osteotomy with internal fixation. In 11 patients, cervical osteotomy was performed in a sitting position with halo-cast immobilization (group S), five patients underwent surgery in prone position with Mayfield clamp fixation (group P). In group P, longer fusion towards T4-T6 could be obtained that created a more stable fixation. Therefore, post-operative immobilization protocol of group P was simplified from halo-cast to cervical orthosis. Consolidation was obtained in all patients without loss of correction. Post-operative chin-brow to vertical angle measured 5 degrees (range 0-15). TES-MEP was successfully performed during all surgical procedures. In total, nine neurological events were registered. Additional surgical intervention resulted in recovery of amplitudes in six of nine events. In two patients spontaneous recovery took place. One patient showed no recovery of amplitudes despite surgical intervention and a partial C6 spinal cord lesion occurred. We conclude that C7 osteotomy with internal fixation has been shown to be a reliable and stable technique. When surgery is performed the in prone position, distal fixation can be optimally obtained allowing post-operative treatment by cervical orthosis instead of a halo-cast. TES-MEP monitoring has been shown to be a reliable neuromonitoring technique with high clinical relevancy during cervical osteotomy because it allows timely intervention before occurrence of permanent cord damage in a large proportion of the patients.

  1. Hemivertebra resection with posterior unilateral intervertebral fusion and transpedicular fixation for congenital scoliosis: results with at least 3 years of follow-up.

    PubMed

    Feng, Yi; Hai, Yong; Zhao, Sheng; Zang, Lei

    2016-10-01

    The main treatment for congenital scoliosis is posterior hemivertebra resection with bilateral transpedicular fixation. Reports describing posterior unilateral intervertebral fusion and transpedicular screw fixation are rare, with no long-term follow-up results, especially in older children. Retrospective analysis of the long-term outcomes of unilateral fusion and fixation after hemivertebra resection for congenital scoliosis. From April 2004 to May 2012, 19 consecutive cases (12 males; age range 2.3-13.4 years) of congenital scoliosis treated by hemivertebra resection with posterior unilateral or bilateral exposure and unilateral intervertebral fusion with transpedicular screw instrumentation alone were investigated retrospectively. All cases were followed-up for at least 3 years. The mean Cobb angle of the segmental scoliosis was improved from 34.8 to 13.4° (correction rate 61.5 %). The mean Cobb angle of the segmental kyphosis was improved from 23.5 to 5.8° (correction rate 75.3 %). The mean correction rates of compensatory cranial and caudal curves were 46.1 and 54.5 %, respectively. 11 patients (57.8 %) exhibited continuous segmental curve improvement during the follow-up. One pedicle fracture and one instrumentation failure were recorded. Unilateral transpedicular screw fixation provides satisfactory correction of the spinal deformity in both very young and older children. Unilateral intervertebral fusion and transpedicular fixation represents an advisable alternative method for the correction of congenital scoliosis and has advantages of reduced trauma, less surgery time and lower expense. Furthermore, the non-fused concave side offers the opportunity for correction of subsequent spine deformity.

  2. Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine

    PubMed Central

    Guo, Fei; Dai, Jianhao; Zhang, Junxiang; Ma, Yichuan; Zhu, Guanghui; Shen, Junjie; Niu, Guoqi

    2017-01-01

    Purpose Pedicle screw fixation in the upper cervical spine is a difficult and high-risk procedure. The screw is difficult to place rapidly and accurately, and can lead to serious injury of spinal cord or vertebral artery. The aim of this study was to design an individualized 3D printing navigation template for pedicle screw fixation in the upper cervical spine. Methods Using CT thin slices data, we employed computer software to design the navigation template for pedicle screw fixation in the upper cervical spine (atlas and axis). The upper cervical spine models and navigation templates were produced by 3D printer with equal proportion, two sets for each case. In one set (Test group), pedicle screws fixation were guided by the navigation template; in the second set (Control group), the screws were fixed under fluoroscopy. According to the degree of pedicle cortex perforation and whether the screw needed to be refitted, the fixation effects were divided into 3 types: Type I, screw is fully located within the vertebral pedicle; Type II, degree of pedicle cortex perforation is <1 mm, but with good internal fixation stability and no need to renovate; Type III, degree of pedicle cortex perforation is >1 mm or with the poor internal fixation stability and in need of renovation. Type I and Type II were acceptable placements; Type III placements were unacceptable. Results A total of 19 upper cervical spine and 19 navigation templates were printed, and 37 pedicle screws were fixed in each group. Type I screw-placements in the test group totaled 32; Type II totaled 3; and Type III totaled 2; with an acceptable rate of 94.60%. Type I screw placements in the control group totaled 23; Type II totaled 3; and Type III totaled 11, with an acceptable rate of 70.27%. The acceptability rate in test group was higher than the rate in control group. The operation time and fluoroscopic frequency for each screw were decreased, compared with control group. Conclusion The individualized 3D printing navigation template for pedicle screw fixation is easy and safe, with a high success rate in the upper cervical spine surgery. PMID:28152039

  3. Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine.

    PubMed

    Guo, Fei; Dai, Jianhao; Zhang, Junxiang; Ma, Yichuan; Zhu, Guanghui; Shen, Junjie; Niu, Guoqi

    2017-01-01

    Pedicle screw fixation in the upper cervical spine is a difficult and high-risk procedure. The screw is difficult to place rapidly and accurately, and can lead to serious injury of spinal cord or vertebral artery. The aim of this study was to design an individualized 3D printing navigation template for pedicle screw fixation in the upper cervical spine. Using CT thin slices data, we employed computer software to design the navigation template for pedicle screw fixation in the upper cervical spine (atlas and axis). The upper cervical spine models and navigation templates were produced by 3D printer with equal proportion, two sets for each case. In one set (Test group), pedicle screws fixation were guided by the navigation template; in the second set (Control group), the screws were fixed under fluoroscopy. According to the degree of pedicle cortex perforation and whether the screw needed to be refitted, the fixation effects were divided into 3 types: Type I, screw is fully located within the vertebral pedicle; Type II, degree of pedicle cortex perforation is <1 mm, but with good internal fixation stability and no need to renovate; Type III, degree of pedicle cortex perforation is >1 mm or with the poor internal fixation stability and in need of renovation. Type I and Type II were acceptable placements; Type III placements were unacceptable. A total of 19 upper cervical spine and 19 navigation templates were printed, and 37 pedicle screws were fixed in each group. Type I screw-placements in the test group totaled 32; Type II totaled 3; and Type III totaled 2; with an acceptable rate of 94.60%. Type I screw placements in the control group totaled 23; Type II totaled 3; and Type III totaled 11, with an acceptable rate of 70.27%. The acceptability rate in test group was higher than the rate in control group. The operation time and fluoroscopic frequency for each screw were decreased, compared with control group. The individualized 3D printing navigation template for pedicle screw fixation is easy and safe, with a high success rate in the upper cervical spine surgery.

  4. Pedicle distraction increases intervertebral and spinal canal area in a cadaver and bone model

    PubMed Central

    Hughes, Matthew; Papadakos, Nikolaos; Bishop, Tim; Bernard, Jason

    2018-01-01

    Introduction: Lumbar spinal stenosis is degenerative narrowing of the spinal canal and/or intervertebral foramen causing compression of the spinal cord and nerve roots. Traditional decompression techniques can often cause significant trauma and vertebral instability. This paper evaluates a method of increasing pedicle length to decompress the spinal and intervertebral foramen, which could be done minimally invasive. Methods: Three Sawbone (Sawbones Europe, Sweden) and 1 cadaveric lumbar spine underwent bilateral pedicle distraction at L4. A pedicle channel was drilled between the superior articular process and transverse process into the vertebral body. The pedicles underwent osteotomy at the midpoint. Screws were inserted bilaterally and fixated distraction of 0 mm, 2 mm, 4 mm and 6 mm. CT images were taken at each level of distraction. Foramen area was measured in the sagittal plane at L3/4. Spinal canal area was measured at L4 in the axial images. The cadaver was used to evaluate safety of osteotomy and soft tissue interactions preventing distraction. Statistical analysis was by student paired t-test and Pearson rank test. Results: Increasing distraction led to greater Spinal canal area. From 4.27 cm2 to 5.72 cm2 (p = 0.002) with 6 mm distraction. A Maximal increase of 34.1%. Vertebral foramen area also increased with increasing pedicle distraction. From 2.43 cm2 to 3.22 cm2 (p = 0.022) with 6 mm distraction. A maximal increase of 32.3%. The cadaver spinal canal increased in area by 21.7%. The vertebral foramen increased in area by 36.2% (left) and 22.6% (right). Discussion: For each increase in pedicle distraction the area of the spinal and vertebral foramen increases. Pedicle distraction could potentially be used to alleviate spinal stenosis and root impingement. A potential osteotomy plane could be at the midpoint of the pedicle with minimal risk to nerve roots and soft tissue restrictions to prevent distraction. PMID:29727270

  5. Pedicle distraction increases intervertebral and spinal canal area in a cadaver and bone model.

    PubMed

    Hughes, Matthew; Papadakos, Nikolaos; Bishop, Tim; Bernard, Jason

    2018-01-01

    Lumbar spinal stenosis is degenerative narrowing of the spinal canal and/or intervertebral foramen causing compression of the spinal cord and nerve roots. Traditional decompression techniques can often cause significant trauma and vertebral instability. This paper evaluates a method of increasing pedicle length to decompress the spinal and intervertebral foramen, which could be done minimally invasive. Three Sawbone (Sawbones Europe, Sweden) and 1 cadaveric lumbar spine underwent bilateral pedicle distraction at L4. A pedicle channel was drilled between the superior articular process and transverse process into the vertebral body. The pedicles underwent osteotomy at the midpoint. Screws were inserted bilaterally and fixated distraction of 0 mm, 2 mm, 4 mm and 6 mm. CT images were taken at each level of distraction. Foramen area was measured in the sagittal plane at L3/4. Spinal canal area was measured at L4 in the axial images. The cadaver was used to evaluate safety of osteotomy and soft tissue interactions preventing distraction. Statistical analysis was by student paired t-test and Pearson rank test. Increasing distraction led to greater Spinal canal area. From 4.27 cm 2 to 5.72 cm 2 (p = 0.002) with 6 mm distraction. A Maximal increase of 34.1%. Vertebral foramen area also increased with increasing pedicle distraction. From 2.43 cm 2 to 3.22 cm 2 (p = 0.022) with 6 mm distraction. A maximal increase of 32.3%. The cadaver spinal canal increased in area by 21.7%. The vertebral foramen increased in area by 36.2% (left) and 22.6% (right). For each increase in pedicle distraction the area of the spinal and vertebral foramen increases. Pedicle distraction could potentially be used to alleviate spinal stenosis and root impingement. A potential osteotomy plane could be at the midpoint of the pedicle with minimal risk to nerve roots and soft tissue restrictions to prevent distraction. © The Authors, published by EDP Sciences, 2018.

  6. The recovery of 5-HT transporter and 5-HT immunoreactivity in injured rat spinal cord.

    PubMed

    Saruhashi, Yasuo; Matsusue, Yoshitaka; Fujimiya, Mineko

    2009-09-01

    Experimental spinal cord injury. To determine the role of serotonin (5-HT) and 5-HT transporter in recovery from spinal cord injury. We examined 5-HT and 5-HT transporter of spinal cord immunohistologically and assessed locomotor recovery after extradural compression at the thoracic (T8) spinal cord in 21 rats. Eighteen rats had laminectomy and spinal cord injury, while the remaining three rats received laminectomy only. All rats were evaluated every other day for 4 weeks, using a 0-14 point scale open field test. Extradural compression markedly reduced mean hindlimbs scores from 14 to 1.5 +/- 2.0 (mean +/- standard error of mean). The rats recovered apparently normal walking by 4 weeks. The animals were perfused with fixative 1-3 days, 1, 2 and 4 weeks (three rats in each) after a spinal cord injury. The 5-HT transporter immunohistological study revealed a marked reduction of 5-HT transporter-containing terminals by 1 day after injury. By 4 weeks after injury, 5-HT transporter immunoreactive terminals returned to the control level. The 5-HT immunohistological study revealed a reduction of 5-HT-containing terminals by 1 week after injury. By 4 weeks after injury, 5-HT immunoreactive fibers and terminals returned to the control level. We estimated the recovery of 5-HT transporter and 5-HT neural elements in lumbosacral ventral horn by ranking 5-HT transporter and 5-HT staining intensity and counting 5-HT and 5-HT transporter terminals. The return of 5-HT transporter and 5-HT immunoreactivity of the lumbosacral ventral horn correlated with locomotor recovery, while 5-HT transporter showed closer relationship with locomotor recovery than 5-HT. The presence of 5-HT transporter indicates that the 5-HT fibers certainly function. This study shows that return of the function of 5-HT fibers predict the time course and extent of locomotory recovery after thoracic spinal cord injury.

  7. Electrochemotherapy of Spinal Metastases Using Transpedicular Approach—A Numerical Feasibility Study

    PubMed Central

    Cindrič, Helena; Tedesco, Giuseppe; Cadossi, Matteo; Gasbarrini, Alessandro; Miklavčič, Damijan

    2018-01-01

    Vertebral column is the most frequent site for bone metastases. It has been demonstrated in previous studies that bone metastases can be efficiently treated by electrochemotherapy. We developed a novel approach to treat spinal metastases, that is, transpedicular approach that combines electrochemotherapy with already established technologies for insertion of fixation screws in spinal surgery. In the transpedicular approach, needle electrodes are inserted into the vertebral body through pedicles and placed around the tumor. The main goal of our study was to numerically investigate the feasibility of the proposed treatment approach. Three clinical cases were used in this study—1 with a tumor completely contained within the vertebral body and 2 with tumors spread also to the pedicles and spinal canal. Anatomically accurate numerical models were built for all 3 cases, and numerical computations of electric field distribution in tumor and surrounding tissue were performed to determine the treatment outcome. Complete coverage of tumor volume with sufficiently high electric field is a prerequisite for successful electrochemotherapy. Close to 100% tumor coverage was obtained in all 3 cases studied. Two cases exhibited tumor coverage of >99%, while the coverage in the third case was 98.88%. Tumor tissue that remained untreated was positioned on the margin of the tumor volume. We also evaluated hypothetical damage to spinal cord and nerves. Only 1 case, which featured a tumor grown into the spinal canal, exhibited potential risk of neural damage. Our study shows that the proposed transpedicular approach to treat spinal metastases is feasible and safe if the majority of tumor volume is contained within the vertebral body. In cases where the spinal cord and nerves are contained within the margin of the tumor volume, a successful and safe treatment is still possible, but special attention needs to be given to evaluation of potential neural damage. PMID:29759043

  8. Miniplate fixation of Le Fort I osteotomies.

    PubMed

    Rosen, H M

    1986-12-01

    The use of rigid, internal, three-dimensional fixation using vitallium bone plates in 28 consecutive Le Fort I osteotomies is presented. A minimum follow-up period of 6 months was required for inclusion in this patient group. Maxillary movements included advancements (17), intrusions (9), lengthenings (5), and retrusions (2). The majority of maxillae were moved in more than one plane of space. Technical details, complications, and relapse potential are discussed. Advantages of rigid plate fixation include marked reductions in the length of intermaxillary fixation with light training elastics only. Immediate postoperative airway problems are thereby eliminated. Six months of follow-up would appear to indicate a low potential for osseous relapse when compared to wire osteosynthesis, regardless of the direction of maxillary movement. The major disadvantage is the decreased ability of postoperative orthodontics to move dento-osseous segments if skeletal occlusal disharmony persists postoperatively. For this reason, close attention to preoperative planning and operative technique is critical for the success of this fixation method.

  9. [Atlanto-axial pedicle screw fixation through posterior approach for treatment of atlanto-axial joint instability].

    PubMed

    Zuo, Chun-Guang; Liu, Xia-Jun; Wang, Xin-Hu; Wang, Jian-shun

    2013-01-01

    To discuss the therapeutic effects of the atlantoaxial pedicle screw system fixation in treatment of atlantoaxial instability. From June 2003 to March 2010, 32 patients with atlantoaxial instability were treated by atlantoaxial pedicle screw system fixation, included 21 males and 11 females wiht an average age of 42.5 years old ranging from 28 to 66 years. Among them, 18 cases were odontoid process fractures, 7 were congenital dissociate odontoid process, 4 were Jefferson fracture combined with odontoid fracture, 3 were rheumatic arthritis causing atlantoaxial instability. All patients suffered from the atlantoaxial subluxation and atlantoaxial instability. The JOA score ranged from 4 to 14 (means 9.1 +/- 0.3) before operation. The patients had some image examination including the X-ray of cervical vertebrae (include of dynamic position film), spiral CT 3D reconstruction and/or MRI. The position of pedicle screw system implantation,the angle of pedicle screw system implantation and screw length were measured. Operating skull traction. Operation undewent general anesthesia, implanted the pedicle screw, reduction and bone fusion under direct vision. The bone was fixated between posterior arch of atlas and lamina of axis by the lateral combination bended to posterior. One hundred and twenty-eight atlantoaxial pedicle screws were implanted in 32 patients. No patient had the injure of spinal cord, nerve root and vertebral artery. All patients were followed-up from 6 to 48 months (averaged 16 months). After operation, the JOA score ranged from 11 to 17 (averaged 15.9 +/- 0.2), improvement rate was 86.1%. The fracture of odontoid process were healing completely. All fusion bone were combinated. The internal fixation wasn't loosening and breaking. The atlantoaxial pedicle screw system fixation was effective method to treat atlantoaxial instability. The method had many advantages, such as provide rigid and short segment fixation, safe and simple, high fusion rate. The method was worth in clinical application.

  10. Spinal Deformity Correction in Duchenne Muscular Dystrophy (DMD): Comparing the Outcome of Two Instrumentation Techniques

    PubMed Central

    Mehdian, Syed M. Hossein; Webb, John K.

    2011-01-01

    Study Design A retrospective matched cohort study. Purpose To compare the results of combined Luque rod-sublaminar wiring (thoracic) and pedicle (lower lumbar) instrumentation (SLW) versus those with pedicle screw fixation (PS) for scoliosis correction in Duchenne muscular dystrophy (DMD). Overview of Literature PS fixation is gaining popularity. Two instrumentation systems were not compared before in a matched cohort of patients. Methods Two groups of patients with DMD were matched according to the age at surgery, magnitude of deformity and vital capacity. Indications for surgery included loss of sitting balance, rapid decline of vital capacity and curve progression. In group 1 (22 patients) SLW fixation was used from T2/3 to pelvis or sacrum. In group 2 (18 patients) PS fixation was used from T2/3 to L5. Five patients had all level segmental PS fixations. Minimum follow-up was 2 years (range, 2 to 13 years). Radiographs, lung function tests and subjective/objective assessment were performed at standardized intervals. Results Mean Cobb angle in group 1 improved from 45.3° (range, 26 to 75°) to 17.7°(range, 0 to 37°) and mean pelvic obliquity improved from 14.5° (range, 8 to 28°) to 5.6° (range, 0 to 15°). Mean Cobb angle in group 2 improved from 42.8° (range, 28 to 80°) to 7.3° (range, 0 to 20°) and mean pelvic obliquity improved from 11.2° (range, 7 to 30°) to 2.0° (range, 0 to 5°) (p < 0.05). Mean operating time and blood loss were less in group 2 (p < 0.05). In group 1, the infection rate and instrumentation failure was higher, and subjective/objective outcomes showed no significant difference between the groups. Conclusions PS fixation had superior correction and controlled pelvic obliquity without the need for pelvic fixation. PMID:21386945

  11. Condylar Joint Fusion and Stabilization (by Screws and Plates) in Nontraumatic Atlanto-Occipital Dislocation: Technical Report of 2 Cases.

    PubMed

    Chowdhury, Forhad H; Haque, Mohammod Raziul; Alam, Sarwar Murshed; Khaled Chowdhury, S M Noman; Khan, Shamsul Islam; Goel, Atul

    2017-11-01

    Nontraumatic spontaneous atlanto-occipital dislocation (AOD) is rare. In this report, we discuss the technical steps of condylar joint fusion and stabilization (by screws and plates) in nontraumatic AOD. To the best of our knowledge, it is the first report of such techniques. A young girl and a young man with progressive quadriparesis due to nontraumatic spontaneous atlanto-occipital dislocation were managed by microsurgical reduction, fusion, and stabilization of the joint by occipital condylar and C1 lateral mass screw and plate fixation after mobilization of vertebral artery. In both cases, condylar joints fixation and fusion were done successfully. Condylar joint stabilization and fusion may be a good or alternative option for AOD. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. [Clinical application of atlantoaxial pedicle screw internal fixation for treatment of atlantoaxial dislocation].

    PubMed

    Yang, Yong-Jun; Zhang, En-Zhong; Tan, Yuan-Chao; Zhou, Ji-Ping; Yao, Shu-Qiang; Jiang, Chuan-Jie; Cong, Pei-Yan

    2009-11-01

    To investigate the clinical effect of atlantoaxial pedicle screw internal fixation for treatment of atlantoaxial dislocation. Sixteen patients with atlantoaxial dislocation were treated from Dec. 2005 to June 2007, included 10 males and 6 females, aged from 38 to 45 years old (means 40.5 years). Among them 12 patients combined with nerve injury, according to ASIA grade: there were 3 cases in grade B, 5 cases in grade C, 4 cases in grade D. All patients received preoperative CT, radiograph and skull traction. Intraoperative posterior approach general spine pedicle screw-rod orthopaedics fixation system used and iliac bone block were implanted in space of posterior atlantal arch and axial vertebral plate. The outcome and complications were observed in the near future. There was no vascular or neural injury found. The patients were followed up for 12 to 24 months (means 18 months). All head pain, acid storm symptoms were improved after operation. According to the Odom's clinical efficacy evaluation standard, 12 cases were excellent, 4 were good. Eleven cases of 12 with nerve injury recovered significantly. By ASIA classification: 1 cases was in grade B, 2 cases were in grade C, 5 cases were in grade D, 4 cases were in grade E. No looseness or breakage of screw occurred. Bony fusion was achieved in all cases. Posterior approach atlantoaxial pedicle screw internal fixation have the advantages of direct screw placement, short-segment fusion, intraoperative reduction, fixation reliable, high fusion rate, and it can restablish the upper cervical vertebrae stability and help to recover the spinal cord and nerve function.

  13. Application of dual-energy CT to suppression of metal artefact caused by pedicle screw fixation in radiotherapy: a feasibility study using original phantom

    NASA Astrophysics Data System (ADS)

    Wang, Tianyuan; Ishihara, Takeaki; Kono, Atsushi; Yoshida, Naoki; Akasaka, Hiroaki; Mukumoto, Naritoshi; Yada, Ryuichi; Ejima, Yasuo; Yoshida, Kenji; Miyawaki, Daisuke; Kakutani, Kenichiro; Nishida, Kotaro; Negi, Noriyuki; Minami, Toshiaki; Aoyama, Yuuichi; Takahashi, Satoru; Sasaki, Ryohei

    2017-08-01

    The objective of the present study was the determination of the potential dosimetric benefits of using metal-artefact-suppressed dual-energy computed tomography (DECT) images for cases involving pedicle screw implants in spinal sites. A heterogeneous spinal phantom was designed for the investigation of the dosimetric effect of the pedicle-screw-related artefacts. The dosimetric comparisons were first performed using a conventional two-directional opposed (AP-PA) plan, and then a volumetric modulated arc therapy (VMAT) plan, which are both used for the treatment of spinal metastases in our institution. The results of Acuros® XB dose-to-medium (Dm) and dose-to-water (Dw) calculations using different imaging options were compared with experimental measurements including the chamber and film dosimetries in the spinal phantom. A dual-energy composition image with a weight factor of  -0.2 and a dual-energy monochromatic image (DEMI) with an energy level of 180 keV were found to have superior abilities for artefact suppression. The Dm calculations revealed greater dosimetric effects of the pedicle screw-related artefacts compared to the Dw calculations. The results of conventional single-energy computed tomography showed that, although the pedicle screws were made from low-Z titanium alloy, the metal artefacts still have dosimetric effects, namely, an average (maximum) Dm error of 4.4% (5.6%) inside the spinal cord for a complex VMAT treatment plan. Our findings indicate that metal-artefact suppression using the proposed DECT (DEMI) approach is promising for improving the dosimetric accuracy near the implants and inside the spinal cord (average (maximum) Dm error of 1.1% (2.0%)).

  14. Real-time monitoring of spinal cord blood flow with a novel sensor mounted on a cerebrospinal fluid drainage catheter in an animal model.

    PubMed

    Hayatsu, Yukihiro; Kawamoto, Shunsuke; Matsunaga, Tadao; Haga, Yoichi; Saiki, Yoshikatsu

    2014-10-01

    The aim of our study was to develop a novel monitoring system for spinal cord blood flow (SCBF) to test the efficacy of the SCBF sensor in an animal model. The sensor system consisted of 2 optical fibers, a pedestal for fiber fixation, and a mirror for the laser reflection and was incorporated into a cerebrospinal fluid drainage catheter. In vivo studies were performed in a swine model (n=10) to measure SCBF during spinal cord ischemia induced by clamping the descending thoracic aorta and supra-aortic neck vessels, when necessary. A temporary low cardiac output model was also created by inflow clamping of the inferior vena cava to analyze the quantitative changes in SCBF during this maneuver. The developed SCBF monitoring catheter placed intrathecally could detect SCBF in all the swine. The SCBF after aortic crossclamping at the fourth intercostal level exhibited diverse changes reproducibly among the swine, with a >25% reduction in SCBF in 5 pigs, an increase in 3, and no significant changes in 2. Consistent reductions were recorded during inferior vena cava occlusion. The mean SCBF decreased by 32% after inferior vena cava occlusion when the cardiac output had decreased by 27%. We have developed a novel SCBF sensor that could detect real-time changes in spinal cord perfusion in a swine model. The device holds promise to detect imminent ischemia or ensure acceptable blood perfusion in the spinal cord and could further enhance our understanding of spinal cord circulation. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  15. Lumbar Spinous Process Fixation and Fusion: A Systematic Review and Critical Analysis of an Emerging Spinal Technology.

    PubMed

    Lopez, Alejandro J; Scheer, Justin K; Dahdaleh, Nader S; Patel, Alpesh A; Smith, Zachary A

    2017-11-01

    A systematic review. The available literature on interspinous rigid fixation/fusion devices (IFD) was systematically reviewed to explore the devices' efficacy and complication profile. The clinical application of new spinal technologies may proceed without well-established evidence, as is the case with IFDs. IFDs are plate-like devices that are attached to the lateral aspects of 2 adjacent spinous processes to promote rigidity at that segment. Despite almost a decade since the devices' introduction, the literature regarding efficacy and safety is sparse. Complications have been reported but no definitive study is known to the authors. A systematic review of the past 10 years of English literature was conducted according to PRISMA guidelines. The timeframe was chosen based on publication of the first study containing a modern IFD, the SPIRE, in 2006. All PubMed publications containing MeSH headings or with title or abstract containing any combination of the words "interspinous," "spinous process," "fusion," "fixation," "plate," or "plating" were included. Exclusion criteria consisted of dynamic stabilization devices (X-Stop, DIAM, etc.), cervical spine, pediatrics, and animal models. The articles were blinded to author and journal, assigned a level of evidence by Oxford Centre of Evidence-Based Medicine (OCEBM) criteria, and summarized in an evidentiary table. A total of 293 articles were found in the initial search, of which 15 remained after examination for exclusion criteria. No class I or class II evidence regarding IFDs was found. IFDs have been shown by methodologically flawed and highly biased class III evidence to reduce instability at 1 year, without statistical comparison of complication rates against other treatment modalities. Although IFDs are heavily marketed and commonly applied in modern practice, data on safety and efficacy are inadequate. The paucity of evidence warrants reexamination of these devices' value and indications by the spine surgery community.

  16. Spinal Bracing

    NASA Technical Reports Server (NTRS)

    1991-01-01

    Dr. Arthur Copes of the Copes Foundation, Baton Rouge, LA, says that 35 percent of the 50 technical reports he received from the NASA/Southern University Industrial Applications Center in Baton Rouge and the Central Industrial Applications Center, Durant, OK, were vital to the development of his Copes Scoliosis Braces, which are custom designed and feature a novel pneumatic bladder that exerts constant corrective pressure to the torso to slowly reduce or eliminate the spinal curve.

  17. Usability assessment of ASIBOT: a portable robot to aid patients with spinal cord injury.

    PubMed

    Jardón, Alberto; Gil, Ángel M; de la Peña, Ana I; Monje, Concepción A; Balaguer, Carlos

    2011-01-01

    The usability concept refers to aspects related to the use of products that are closely linked to the user's degree of satisfaction. Our goal is to present a functional evaluation methodology for assessing the usability of sophisticated technical aids, such as a portable robot for helping disabled patients with severe spinal cord injuries. The specific manipulator used for this task is ASIBOT, a personal assistance robot totally developed by RoboticsLab at the University Carlos III of Madrid. Our purpose is also to improve some aspects of the manipulator according to the user's perception. For our case study, a population of six patients with spinal cord injury is considered. These patients have been suffering spinal cord injuries for a period of time longer than 1 year before the tests are carried out. The methodology followed for the information gathering is based on the Quebec User Evaluation of Satisfaction with assistive Technology (QUEST). Different daily functions, such as drinking, brushing one's teeth and washing one's face, are considered to assess the user's perception when using ASIBOT as a technical aid. The human factor in this procedure is the main base to establish the specific needs and tools to make the end product more suitable and usable.

  18. Skin Graft Fixation Using Hydrofiber (Aquacel® Extra).

    PubMed

    Yen, Ya-Hui; Lin, Chih-Ming; Hsu, Honda; Chen, Ying-Chen; Chen, Yi-Wen; Li, Wan-Yu; Hsieh, Chia-Nan; Huang, Chieh-Chi

    2018-06-01

    The traditional method of skin graft fixation is with tie-over bollus dressing. The use of splints in the extremities for skin graft fixation is a common practice. However, these splints are heavy and uncomfortable and contribute considerably to our overall medical waste. Hydrofiber (Aquacel Extra) has a strong fluid absorption property and fixates well to the underlying wound once applied. In this study, we used hydrofiber for fixation, avoiding the use of splints after skin grafting. A total of 56 patients reconstructed with split-thickness skin graft that was fixated only with hydrofiber between March 2015 and March 2016 were included in this retrospective study. There were 44 men and 12 women with a mean age of 61 ± 18 years. The defect size ranged from 1 × 1 cm for fingertips to 30 × 12 cm for lower limb defects. The average defect size was 61 ± 78 cm. The mean skin graft take was 96% ± 6%. Because splints were not required, we saved around 48 kg of medical waste over the space of 1 year. The use of hydrofiber for skin graft fixation was effective and technically very simple. Splints were not required with this method, decreasing the medical waste created and increasing patient comfort. We suggest that this is an excellent alternative for skin graft fixation while at the same time decreasing our carbon footprint as surgeons.

  19. Percutaneous Radiofrequency Ablation of Painful Spinal Tumors Adjacent to the Spinal Cord with Real-Time Monitoring of Spinal Canal Temperature: A Prospective Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakatsuka, Atsuhiro, E-mail: nakatuka@clin.medic.mie-u.ac.jp; Yamakado, Koichiro; Takaki, Haruyuki

    2009-01-15

    PurposeTo prospectively evaluate the feasibility, safety, and clinical utility of bone radiofrequency (RF) ablation with real-time monitoring of the spinal canal temperature for the treatment of spinal tumors adjacent to the spinal cord.Materials and MethodsOur Institutional Review Board approved this study. Patients gave informed consent. The inclusion criteria were (a) a painful spinal metastasis and (b) a distance of 1 cm or less between the metastasis and the spinal cord. The thermocouple was placed in the spinal canal under CT fluoroscopic guidance. When the spinal canal temperature reached 45{sup o}C, RF application was immediately stopped. RF ablation was considered technicallymore » successful when the procedure was performed without major complications. Clinical success was defined as a fall in the visual analogue scale score of at least 2 points.ResultsTen patients with spinal tumors measuring 3-8 cm (mean, 4.9 {+-} 1.5 cm) were enrolled. The distance between the tumor and the spinal cord was 1-6 mm (mean, 2.4 {+-} 1.6 mm). All procedures were judged technically successful (100%). The spinal canal temperature did not exceed 45{sup o}C in 9 of the 10 patients (90%). In the remaining patient, the temperature rose to 48{sup o}C, resulting in transient neural damage, although RF application was immediately stopped when the temperature reached 45{sup o}C. Clinical success was achieved within 1 week in all patients (100%).ConclusionBone RF ablation with real-time monitoring of the spinal canal temperature is feasible, safe, and clinically useful for the treatment of painful spinal metastases adjacent to the spinal cord.« less

  20. Reduction and fixation of cranial cervical fracture/luxations using screws and polymethylmethacrylate (PMMA) cement: a distraction technique applied to the base of the skull in thirteen dogs.

    PubMed

    Pike, Fred S; Kumar, M S A; Boudrieau, Randy J

    2012-02-01

    To (1) describe a surgical distraction technique for C1-2 cervical fractures/luxations or atlantoaxial (AA) subluxations using the base of the skull (basion of the foramen magnum) and either C2-3 or C3-4 for the purchase points of intraoperative axial distraction and (2) report outcome in 13 dogs. Retrospective case series. Dogs (n = 13). Medical records (September 1995-December 2005) of dogs with fracture/luxation of the cervical spine, or AA subluxations, were reviewed. Only dogs that had intraoperative linear distraction using the base of the skull as a purchase point for a self-retaining retractor were included. Signalment, presenting neurologic deficits, fracture location, and concurrent injury were recorded. Both short-term in-hospital follow-up, including healing and any complications, and long-term telephone follow-up were obtained. Realignment of the spinal vertebrae, reestablishing the normal properties of the spinal canal, was achieved after distraction in all dogs. Screws and small pins incorporated into polymethylmethacrylate cement were used to span the fracture ventrally and achieve rigid internal fixation. Eight dogs had a complete neurologic recovery, 2 dogs had slight residual ataxia, 2 dogs died, and 1 dog was lost to follow-up. Healing was good (mean, 7.5 weeks) or excellent (mean, 5.1 months) based on in-hospital follow-up (mean, 5.1 months). On final telephone follow-up (mean, 7.7 years), no dogs were reported to have had any associated problems or additional surgery. This surgical distraction technique was a reliable, relatively simple method to obtain reduction of fracture/luxations of C1-2 to re-align the spinal canal. Mortality in this series appears lower than that previously reported and supports surgical management of these injuries. © Copyright 2011 by The American College of Veterinary Surgeons.

  1. Extensive Corrective Fixation Surgeries for Adult Spinal Deformity Improve Posture and Lower Extremity Kinematics During Gait.

    PubMed

    Arima, Hideyuki; Yamato, Yu; Hasegawa, Tomohiko; Kobayashi, Sho; Yoshida, Go; Yasuda, Tatsuya; Banno, Tomohiro; Oe, Shin; Mihara, Yuki; Togawa, Daisuke; Matsuyama, Yukihiro

    2017-10-01

    Longitudinal cohort. The present study aimed to document changes in posture and lower extremity kinematics during gait in patients with adult spinal deformity (ASD) after extensive corrective surgery. Standing radiographic parameters are typically used to evaluate patients with ASD. Previously, preoperative walking and standing posture discrepancy were reported in patients with ASD. We did not include comparison between before and after surgery. Therefore, we thought that pre- and postoperative evaluations for patients with ASD should include gait analysis. Thirty-nine patients with ASD (5 men, 34 women; mean age, 71.0 ± 6.1) who underwent posterior corrective fixation surgeries from the thoracic spine to the pelvis were included. A 4-m walk was recorded and analyzed. Sagittal balance while walking was calculated as the angle between the plumb line on the side and the line connecting the greater trochanter and pinna while walking (i.e., the gait-trunk tilt angle [GTA]). We measured maximum knee extension angle during one gait cycle, step length (cm), and walking speed (m/min). Radiographic parameters were also measured. The mean GTA and the mean maximum knee extension angle significantly improved from 13.4° to 6.4°, and -13.3° to -9.4°(P < 0.001 and P = 0.006), respectively. The mean step length improved from 40.4 to 43.1 cm (P = 0.049), but there was no significant change in walking speed (38.4 to 41.5 m/min, P = 0.105). Postoperative GTA, maximum knee extension angle and step length correlated with postoperative pelvic incidence minus lumbar lordosis (r = 0.324, P = 0.044; r = -0.317, P = 0.049; r = -0.416, P = 0.008, respectively). Our results suggest that postoperative posture, maximum knee extension angle, and step length during gait in patients with ASD improved corresponding to how much correction of the sagittal spinal deformity was achieved. 3.

  2. Intraoperative indocyanine green videoangiography for spinal vascular lesions: case report.

    PubMed

    Murakami, Tomohiro; Koyanagi, Izumi; Kaneko, Takahisa; Iihoshi, Satoshi; Houkin, Kiyohiro

    2011-03-01

    In surgery of spinal vascular lesions such as spinal arteriovenous fistula or vascular tumors, assessment of feeding arteries and draining veins is important. Intraoperative digital subtraction angiography is useful but is invasive and sometimes technically demanding. Near-infrared indocyanine green (ICG) videoangiography is less invasive and has been reported as an intraoperative diagnosis of arterial patency during clipping surgery of cerebral aneurysms or bypass surgeries. We present our experience with intraoperative ICG videoangiography in 3 cases of spinal vascular lesions. Two patients had spinal arteriovenous fistula (perimedullary, n = 1; dural, n = 1), and 1 patient had spinal cord hemangioblastoma at the thoracic or thoracolumbar level. The surgical microscope was an OPMI Pentero (Carl Zeiss, Oberkochen, Germany). After laminectomy and opening of the dura, ICG (5 mg) was injected intravenously. The ICG angiography clearly demonstrated feeding and draining vessels. The ICG findings greatly helped successful interruption of arteriovenous fistula and total removal of the tumor. Intraoperative ICG videoangiography for spinal vascular lesions was useful by providing information on vascular dynamics directly. However, the diagnostic area is limited to the field of the surgical microscope. Although intraoperative digital subtraction angiography is still needed in cases of complex spinal vascular lesions, ICG videoangiography will be an important diagnostic modality in the field of spinal vascular surgeries.

  3. Technical considerations for surgical intervention of Jones fractures.

    PubMed

    Mendicino, Robert W; Hentges, Matthew J; Mendicino, Michael R; Catanzariti, Alan R

    2013-01-01

    Jones fractures are a common injury treated by foot and ankle surgeons. Surgical intervention is recommended because of the high rate of delayed union, nonunion, and repeat fracture, when treated conservatively. Percutaneous intramedullary screw fixation is commonly used in the treatment of these fractures. We present techniques that can increase the surgical efficiency and decrease the complications associated with percutaneous delivery of internal fixation. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Surgical Management for Destructive Atlantoaxial Spondyloarthropathy in Long-Term Hemodialysis Patients.

    PubMed

    Jeong, Je Hoon; Kim, Hee Kyung; Im, Soo Bin

    2017-01-01

    Atlantoaxial spondyloarthropathy most often results from rheumatoid arthritis, cancer metastasis, or basilar invagination. Dialysis-related spondyloarthropathy is a rare cause of spinal deformity and cervical myelopathy at the atlantoaxial joint. We report 2 patients on long-term hemodialysis who presented with atlantoaxial spondyloarthropathy. Two patients with end-stage renal failure presented with a history of progressively worsening neck pain, motion limitation, and gait disturbance. In both patients, radiologic findings showed a bone-destroying soft tissue mass lateral to C1 and C2, compressing the spinal cord and causing atlantoaxial instability. We performed a C1 laminectomy and C12 transarticular screw fixation and biopsied the osteolytic mass. The neck pain, hand numbness, and gait disturbance improved. Although the surgical management of these patients involves many challenges, appropriate decompression and fusion surgery is an effective treatment option. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. The evolution of image-guided lumbosacral spine surgery.

    PubMed

    Bourgeois, Austin C; Faulkner, Austin R; Pasciak, Alexander S; Bradley, Yong C

    2015-04-01

    Techniques and approaches of spinal fusion have considerably evolved since their first description in the early 1900s. The incorporation of pedicle screw constructs into lumbosacral spine surgery is among the most significant advances in the field, offering immediate stability and decreased rates of pseudarthrosis compared to previously described methods. However, early studies describing pedicle screw fixation and numerous studies thereafter have demonstrated clinically significant sequelae of inaccurate surgical fusion hardware placement. A number of image guidance systems have been developed to reduce morbidity from hardware malposition in increasingly complex spine surgeries. Advanced image guidance systems such as intraoperative stereotaxis improve the accuracy of pedicle screw placement using a variety of surgical approaches, however their clinical indications and clinical impact remain debated. Beginning with intraoperative fluoroscopy, this article describes the evolution of image guided lumbosacral spinal fusion, emphasizing two-dimensional (2D) and three-dimensional (3D) navigational methods.

  6. Innovations in interventional pain management of chronic spinal pain.

    PubMed

    Manchikanti, Laxmaiah; Boswell, Mark V; Hirsch, Joshua A

    2016-09-01

    Interventional pain management dates back to 1901, with significant innovations, which include the definition, literature synthesis, pathophysiology, and technical interventions. Interventional pain management and interventional techniques include neural blockade, neural ablative procedures, spinal cord and peripheral nerve stimulation, intrathecal drug delivery systems, minimally invasive lumbar decompression (MILD®), percutaneous endoscopic spinal decompression, and regenerative medicine. In addition, advances are also related to the evidence synthesis of comparative effectiveness research. Expert commentary: Multiple innovations in interventional pain management and potential innovations may reduce costs and improve care and outcomes with proper evidence synthesis and application of principles of evidence-based medicine. Innovations in interventional pain management in managing chronic spinal pain depend on extensive research and appropriate evidence synthesis. Innovations should be developed in conjunction with health care policy based on principles of evidence-based medicine.

  7. Treatment of war injuries of the shoulder with external fixators.

    PubMed

    Davila, Slavko; Mikulić, Danko; Davila, Neda Jarza; Popović, Ljiljana; Zupancić, Bozidar

    2005-05-01

    In this retrospective study, 18 patients with war injuries of the shoulder were reviewed to evaluate the technical problems associated with external fixation and to analyze the incidence of infection and late functional results. The average patient age was 28.5 years. All patients were male. Thirteen patients had explosive wounds, whereas five wounds were caused by gunshot missiles. All injuries were extensive in terms of bone and soft tissue defects. Six patients presented with complex injuries involving neurovascular structures. Sixteen patients were treated with external fixation. Application of the proximal pins of the external fixator through the humeral head was possible in eight patients, the scapula served as the site of proximal fixation in four patients, only the clavicle was available for placement of pins in two patients, and both the scapula and the clavicle had to be pinned to achieve proximal stabilization in two patients. In two patients, fixation was not possible and early amputation was performed. Infection was eventually eradicated in all patients, allowing for adequate soft tissue coverage of the wounds. Analysis of functional results at an average of 6 years after the injury showed a considerable degree of functional deficit in most patients.

  8. Infection after anterior spinal fusion for idiopathic scoliosis using the Cotrel-Dubousset-Hopf system: A clinical case series of three patients.

    PubMed

    Tolk, Jaap J; Willems, Paul C; Punt, Ilona M; van Rhijn, Lodewijk W; van Ooij, André

    2016-01-01

    Three patients with late-onset infection after multilevel instrumented anterior spinal fusion for idiopathic scoliosis, using the Cotrel-Dubousset-Hopf (CDH) system, are presented. The CDH-system is an anterior instrumentation with high biomechanical stability and rigidity, ensuring a stable primary fixation. Unlike after posterior spinal fusion, infection after anterior spinal fusion (ASF) for idiopathic scoliosis has rarely been reported. The files of three patients who developed an infection after ASF for scoliosis using the CDH-system, were reviewed. The clinical presentation and diagnostic and therapeutic options are discussed. All three patients had a late-onset infection of the CDH-system, which was difficult to diagnose because of nonspecific symptoms. Radiographs and technetium bone scan appeared to be of low value. When an abscess was present, this could accurately be diagnosed with MRI or CT imaging. Operative treatment with implant removal and antibiotic therapy was successful in all cases. Late onset infections after ASF using the CDH-system presented with few and nonspecific symptoms. The clinical presentation was mainly characterized by vague abdominal- or back-pain after an interval of normal postoperative recovery, moderately raised infection parameters and inconclusive findings with imaging modalities. As treatment, implant removal, debridement and parenteral antibiotics are recommended. It should be noted though that implant removal poses serious risks for vascular and visceral structures.

  9. EUROSPINE 2016 FULL PAPER AWARD: Wire cerclage can restore the stability of the thoracic spine after median sternotomy: an in vitro study with entire rib cage specimens.

    PubMed

    Liebsch, Christian; Graf, Nicolas; Wilke, Hans-Joachim

    2017-05-01

    The influence of the anterior rib cage on the stability of the human thoracic spine is not completely known. One of the most common surgical interventions on the anterior rib cage is the longitudinal median sternotomy and its fixation by wire cerclage. Therefore, the purpose of this in vitro study was to examine, if wire cerclage can restore the stability of the human thoracic spine after longitudinal median sternotomy. Six fresh frozen human thoracic spine specimens (C7-L1, 56 years in average, range 50-65), including the intact rib cage without intercostal muscles, were tested in a spinal loading simulator and monitored with an optical motion tracking system. While applying 2 Nm pure moment in flexion/extension (FE), lateral bending (LB), and axial rotation (AR), the range of motion (ROM) and neutral zone (NZ) of the functional spinal units of the thoracic spine (T1-T12) were studied (1) in intact condition, (2) after longitudinal median sternotomy, and (3) after sternal closure using wire cerclage. The longitudinal median sternotomy caused a significant increase of the thoracic spine ROM relative to the intact condition (FE: 12° ± 5°, LB: 18° ± 5°, AR: 25° ± 10°) in FE (+12 %) and AR (+22 %). As a result, the sagittal cut faces of the sternum slipped apart visibly. Wire cerclage fixation resulted in a significant decrease of the ROM in AR (-12 %) relative to condition after sternotomy. ROM increased relative to the intact condition, in AR even significantly (+8 %). The NZ showed a proportional behavior compared to the ROM in all loading planes, but it was distinctly higher in FE (72 %) and in LB (82 %) compared to the ROM than in AR (12 %). In this in vitro study, the longitudinal median sternotomy resulted in a destabilization of the thoracic spine and relative motion of the sternal cut faces, which could be rectified by fixation with wire cerclage. However, the stability of the intact condition could not be reached. Nevertheless, a fixation of the sternum should be considered clinically to avoid instability of the spine and sternal pseudarthrosis.

  10. Growth-sparing spinal instrumentation in skeletal dysplasia.

    PubMed

    Karatas, Ali F; Dede, Ozgur; Rogers, Kenneth; Ditro, Colleen P; Holmes, Laurens; Bober, Michael; Shah, Suken A; Mackenzie, William G

    2013-11-15

    Retrospective case series. To report the outcomes of distraction-based, growth-sparing spinal instrumentation in patients with skeletal dysplasia. Patients with skeletal dysplasia with spinal deformity often undergo early fusion, further compromising an already small chest. Nonfusion techniques may provide a safe alternative and allow for thoracic growth. Between 2004 and 2010, 12 children with a diagnosis of various types of skeletal dysplasia underwent growth-sparing spinal instrumentation for severe spinal deformities. The mean duration of treatment with growing rods was 57 months (42-84 mo). Nine patients were treated with growing rods (8 dual, 1 single), and 3 were treated with vertical expandable prosthetic titanium rib (VEPTR; Synthes). Preoperative, initial postoperative, and final follow-up anteroposterior and lateral spine radiographs were measured for magnitude of deformity, junctional kyphosis, and implant failure. The major curve Cobb angle improved from a mean of 79° preoperatively to a mean of 41° at the last follow-up (52%). There was a decrease in mean thoracic kyphosis from 77° preoperatively to 64° at final follow-up and an increase in mean lumbar lordosis from 58° preoperatively to 63° at final follow-up. The mean space available for the lungs increased by 26 mm on the concave and 24 mm on the convex side. Six patients required revision surgery for proximal junctional kyphosis. There were 4 rod failures and 6 hook and 8 screw dislodgements. One patient with vertical expandable prosthetic titanium rib had failed rib fixation that required revision. Growth-sparing spinal instrumentation in patients with skeletal dysplasia and severe spinal deformity has a high complication and revision rate, and surgeons should closely monitor these patients. The complication rate is comparable with previous reports on patients with other diagnoses. However, deformities were well controlled, some trunk growth was achieved, and fusion surgery was delayed in all cases. 4.

  11. Spine Trauma as a Component of Essential Neurosurgery: An Outcomes Analysis from Cambodia.

    PubMed

    Chua, Michelle H; Hong, Raksmey; Rydeth, Tytim; Vycheth, Iv; Nang, Sam; Vuthy, Din; Park, Kee B

    2018-06-01

    In recent years, delivery of cost-effective "essential neurosurgery" in resource-limited communities has been recognized as an indispensable part of health care and a global health priority. The aim of this study was to review outcomes from operative management of spine trauma at a resource-limited government hospital in Phnom Penh, Cambodia, and to provide an epidemiologic report to guide prevention programs. A retrospective review of a prospective neurosurgical database was performed to identify risk factors for spine trauma and severe spinal cord injury (American Spinal Injury Association A or American Spinal Injury Association B) and to evaluate the cost-effectiveness of surgery for patients treated at Preah Kossamak Hospital for subaxial and thoracolumbar spine trauma from 2013 to 2016. Surgical treatment was provided to 277 patients with cervical or thoracolumbar spine trauma, including 36 facet dislocations and 135 thoracolumbar burst fractures at a cost of $100-$280 per surgery. Six patients (2.2%) required treatment for postoperative wound infection. Reoperation was performed in 8 patients (2.9%) for wrong-level surgery. Failure of short-segment pedicle screw fixation was discovered in 4 patients (7.0%). Neurologic improvement was reported by 64 patients (65.3%) with incomplete spinal cord injury and available long-term follow-up. Affordable neurosurgical care can be provided in a safe and sustainable manner to patients with traumatic spine and spinal cord injuries in resource-limited communities. This supports the call for essential neurosurgery to be made available around the world to individuals from all socioeconomic strata. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Medial Meniscus Posterior Root Repair Using a Transtibial Technique.

    PubMed

    Woodmass, Jarret M; Mohan, Rohith; Stuart, Michael J; Krych, Aaron J

    2017-06-01

    The meniscal roots are critical in maintaining the normal shock absorbing function of the meniscus. If a meniscal root tear is left untreated, meniscal extrusion can occur rendering the meniscus nonfunctional resulting in degenerative arthritis. Two main repair techniques are described: (1) suture anchors (direct fixation) and (2) sutures pulled through a tibial tunnel (indirect fixation). Meniscal root repair using a suture anchor technique is technically challenging requiring a posterior portal and a curved suture passing device that can be difficult to manipulate within the knee. We present a technique for posterior medial meniscus root repair using 3 sutures (1 leader, 2 cinch), standard arthroscopy portals, and transtibial fixation. Overall, this technique simplifies a challenging procedure and allows for familiarity and efficiency.

  13. Ligament augmentation for prevention of proximal junctional kyphosis and proximal junctional failure in adult spinal deformity.

    PubMed

    Safaee, Michael M; Deviren, Vedat; Dalle Ore, Cecilia; Scheer, Justin K; Lau, Darryl; Osorio, Joseph A; Nicholls, Fred; Ames, Christopher P

    2018-05-01

    OBJECTIVE Proximal junctional kyphosis (PJK) is a well-recognized, yet incompletely defined, complication of adult spinal deformity surgery. There is no standardized definition for PJK, but most studies describe PJK as an increase in the proximal junctional angle (PJA) of greater than 10°-20°. Ligament augmentation is a novel strategy for PJK reduction that provides strength to the upper instrumented vertebra (UIV) and adjacent segments while also reducing junctional stress at those levels. METHODS In this study, ligament augmentation was used in a consecutive series of adult spinal deformity patients at a single institution. Patient demographics, including age; sex; indication for surgery; revision surgery; surgical approach; and use of 3-column osteotomies, vertebroplasty, or hook fixation at the UIV, were collected. The PJA was measured preoperatively and at last follow-up using 36-inch radiographs. Data on change in PJA and need for revision surgery were collected. Univariate and multivariate analyses were performed to identify factors associated with change in PJA and proximal junctional failure (PJF), defined as PJK requiring surgical correction. RESULTS A total of 200 consecutive patients were included: 100 patients before implementation of ligament augmentation and 100 patients after implementation of this technique. The mean age of the ligament augmentation cohort was 66 years, and 67% of patients were women. Over half of these cases (51%) were revision surgeries, with 38% involving a combined anterior or lateral and posterior approach. The mean change in PJA was 6° in the ligament augmentation group compared with 14° in the control group (p < 0.001). Eighty-four patients had a change in PJA of less than 10°. In a multivariate linear regression model, age (p = 0.016), use of hook fixation at the UIV (p = 0.045), and use of ligament augmentation (p < 0.001) were associated with a change in PJA. In a separate model, only ligament augmentation (OR 0.193, p = 0.012) showed a significant association with PJF. CONCLUSIONS Ligament augmentation represents a novel technique for the prevention of PJK and PJF. Compared with a well-matched historical cohort, ligament augmentation is associated with a significant decrease in PJK and PJF. These data support the implementation of ligament augmentation in surgery for adult spinal deformity, particularly in patients with a high risk of developing PJK and PJF.

  14. Minimally Invasive Direct Lateral Interbody Fusion (MIS-DLIF): Proof of Concept and Perioperative Results.

    PubMed

    Abbasi, Hamid; Abbasi, Ali

    2017-01-14

    Minimally invasive direct lateral interbody fusion (MIS-DLIF) is a novel approach for fusions of the lumbar spine. In this proof of concept study, we describe the surgical technique and report our experience and the perioperative outcomes of the first nine patients who underwent this procedure. In this study we establish the safety and efficacy of this approach. MIS-DLIF was performed on 15 spinal levels in nine patients who failed to respond to conservative therapy for the treatment of a re-herniated disk, spondylolisthesis, or other severe disk disease of the lumbar spine. We recorded surgery time, blood loss, fluoroscopy time, patient-reported pain, and complications. Throughout the MIS-DLIF procedure, the surgeon is aided by biplanar fluoroscopic imaging to place an interbody graft or cage into the disc space through the interpleural space. A discectomy is performed in the same minimally invasive fashion. The procedure is usually completed with posterior pedicle screw fixation. MIS-DLIF took 44/85 minutes, on average, for 1/2 levels, with 54/112 ml of blood loss, and 0.3/1.7 days of hospital stay. Four of nine patients did not require overnight hospitalization and were discharged two to four hours after surgery. We did not encounter any clinically significant complications. At more than ninety days post surgery, the patients reported a statistically significant reduction of 4.5 points on a 10-point sliding pain scale. MIS-DLIF with pedicle screw fixation is a safe and clinically effective procedure for fusions of the lumbar spine. The procedure overcomes many of the limitations of the current minimally invasive approaches to the lumbar spine and is technically straightforward. MIS-DLIF has the potential to improve patient outcomes and reduce costs relative to the current standard of care and therefore warrants further investigation. We are currently expanding this study to a larger cohort and documenting long-term outcome data.

  15. Osteotomy and fracture fixation in children and teenagers.

    PubMed

    de Billy, B; Gindraux, F; Langlais, J

    2014-02-01

    Significant changes have occurred recently in fixation methods following fracture or osteotomy in children and teenagers. Children have benefited the most from these advances. A child's growth is anatomically and physiologically ensured by the growth plate and periosteum. The need to keep the periosteum intact during trauma cases has led to the introduction of flexible intramedullary nailing. We will review the basic principles of this safe, universally adopted technique, and also describe available material, length and diameter options. The problems and the limitations of this method will be discussed extensively. In orthopedics, the desire to preserve the periosteum has led to the use of locking compression plates. Because of their low profile and high stability, they allow the micromovements essential for bone union. These new methods reduce the immobilization period and allow autonomy to be regained more quickly, which is especially important in children with neurological impairment. The need to preserve the growth plate, which is well known in pediatric surgery, is reviewed with the goal of summarizing current experimental data on standard fracture and osteotomy fixation methods. Adjustable block stop wires provide better control over compression. These provide an alternate means of fixation between K-wires and screws (now cannulated) and have contributed to the development of minimally invasive surgical techniques. The aim of this lecture is to provide a rationale for the distinct technical features of pediatric surgery, while emphasizing the close relationship between the physiology of growth, bone healing and technical advances. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  16. A technical report on video-assisted thoracoscopy in thoracic spinal surgery. Preliminary description.

    PubMed

    Regan, J J; Mack, M J; Picetti, G D

    1995-04-01

    This report is a preliminary description of the efficacy of video-assisted thoracoscopic surgery in thoracic spinal procedures that otherwise require open thoracotomy. This report sought to describe the efficacy of video-assisted thoracoscopic surgery in thoracic spinal procedures that otherwise require open thoracotomy. In a landmark study that compared video-assisted thoracoscopic surgery for peripheral lung lesions with thoracotomy, video-assisted thoracoscopic surgery reduced postoperative pain, improved early shoulder girdle function, and shortened hospital stay. Video-assisted thoracoscopic surgery was performed in 12 thoracic spinal patients (herniated nucleus pulposus, infection, tumor, or spinal deformity) and is described in detail in this report. Video-assisted thoracoscopic surgery in thoracic spinal surgery resulted in little postoperative pain, short intensive care unit and hospital stays, and little or no morbidity. In the short follow-up period, there was no post-thoracotomy pain syndrome nor neurologic sequelae in these patients. Operative time decreased dramatically as experience was gained with the procedure. Given consistently improving surgical skills, a number of thoracic spinal procedures using video-assisted thoracoscopic surgery, including thoracic discectomy, internal rib thoracoplasty, anterior osteotomy, corpectomy, and fusion, can be performed safely with no additional surgical time or risk to the patient.

  17. Quiet eye training improves surgical knot tying more than traditional technical training: a randomized controlled study.

    PubMed

    Causer, Joe; Harvey, Adrian; Snelgrove, Ryan; Arsenault, Gina; Vickers, Joan N

    2014-08-01

    We examined the effectiveness of technical training (TT) and quiet eye training (QE) on the performance of one-handed square knot tying in surgical residents. Twenty surgical residents were randomly assigned to the 2 groups and completed pretest, training, retention, and transfer tests. Participants wore a mobile eye tracker that simultaneously recorded their gaze and hand movements. Dependent variables were knot tying performance (%), QE duration (%), number of fixations, total movement time (s), and hand movement phase time (s). The QE training group had significantly higher performance scores, a longer QE duration, fewer fixations, faster total knot tying times, and faster movement phase times compared with the TT group. The QE group maintained performance in the transfer test, whereas the TT group significantly decreased performance from retention to transfer. QE training significantly improved learning, retention, and transfer of surgical knot tying compared with a traditional technical approach. Both performance effectiveness (performance outcome) and movement efficiency (hand movement times) were improved using QE modeling, instruction, and feedback. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Does Atraucan cause more postdural puncture backache?

    PubMed

    Abdullayev, Ruslan; Küçükebe, Omer Burak; Çelik, Bülent; Kirman, Nihal; Hatipoğlu, Hamit Sinan; Akaltun Hatipoğlu, Filiz

    2015-01-01

    Postdural puncture backache (PDPB) is the most frequent complaint after spinal anesthesia. In the literature its importance is generally overshadowed by postdural puncture headache. We studied two different kinds of spinal anesthesia needles to compare their technical handling capacities and incidences of PDPB. Data of 256 pregnant female patients undergoing cesarean delivery under spinal anesthesia were collected for the study. Patients were divided into two groups as Group A (n = 109) and Group Q (n = 147) according to the spinal needle used for spinal anesthesia (i.e. 26-gauge atraumatic and 26-gauge Quincke needles, respectively). Backache incidences during a 1-week period postoperatively and handling characteristics of the needles were noted. Spinal anesthesia was successfully performed at one attempt in 92.7% and 86.4% of patients in Groups A and Q, respectively. PDPB was encountered in 62.4% and 44.2% of patients in Groups A and Q, respectively, and the difference was statistically significant (P = 0.037). Both 26-gauge Atraucan and Quincke needles have excellent handling characteristics. PDPB seems to be less common with the 26-gauge Quincke needle than with the Atraucan needle.

  19. Comparison of open reduction versus minimally invasive surgical approaches on screw position in canine sacroiliac lag-screw fixation.

    PubMed

    Déjardin, Loïc M; Marturello, Danielle M; Guiot, Laurent P; Guillou, Reunan P; DeCamp, Charles E

    2016-07-19

    To compare accuracy and consistency of sacral screw placement in canine pelves treated for sacroiliac luxation with open reduction and internal fixation (ORIF) or minimally invasive osteosynthesis (MIO) techniques. Unilateral sacroiliac luxations created experimentally in canine cadavers were stabilized with an iliosacral lag screw applied via ORIF or MIO techniques (n = 10/group). Dorsoventral and craniocaudal screw angles were measured using computed tomography multiplanar reconstructions in transverse and dorsal planes, respectively. Ratios between pilot hole length and sacral width (PL/SW-R) were obtained. Data between groups were compared statistically (p <0.05). Mean screw angles (±SD) were greater in ORIF specimens in both transverse (p <0.001) and dorsal planes (p <0.004). Mean PL/SW-R was smaller (p <0.001) in the ORIF group, yet was greater than 60%. While pilot holes exited the first sacral end-plate in three of 10 ORIF specimens, the spinal canal was not violated in either group. This study demonstrates that MIO fixation of canine sacroiliac luxations provides more accurate and consistent sacral screw placement than ORIF. With proper techniques, iatrogenic neurological damage can be avoided with both techniques. The PL /SW-R, which relates to safe screw fixation, also demonstrates that screw penetration of at least 60% of the sacral width is achievable regardless of surgical approach. These findings, along with the limited dissection needed for accurate sacral screw placement, suggest that MIO of sacroiliac luxations is a valid alternative to ORIF.

  20. Posterior Titanium Screw Fixation without Debridement of Infected Tissue for the Treatment of Thoracolumbar Spontaneous Pyogenic Spondylodiscitis

    PubMed Central

    Iacoangeli, Maurizio; Nasi, Davide; Nocchi, Niccolo; Di Rienzo, Alessandro; di Somma, Lucia; Colasanti, Roberto; Vaira, Carmela; Benigni, Roberta; Liverotti, Valentina; Scerrati, Massimo

    2016-01-01

    Study Design Retrospective study. Purpose The aim of our study was to analyze the safety and effectiveness of posterior pedicle screw fixation for treatment of pyogenic spondylodiscitis (PSD) without formal debridement of the infected tissue. Overview of Literature Posterior titanium screw fixation without formal debridement of the infected tissue and anterior column reconstruction for the treatment of PSD is still controversial. Methods From March 2008 to June 2013, 18 patients with PSD underwent posterior titanium fixation with or without decompression, according to their neurological deficit. Postero-lateral fusion with allograft transplantation alone or bone graft with both the allogenic bone and the autologous bone was also performed. The outcome was assessed using the visual analogue scale (VAS) for pain and the Frankel grading system for neurological status. Normalization both of C-reactive protein (CRP) and erythrocyte sedimentation rate was adopted as criterion for discontinuation of antibiotic therapy and infection healing. Segmental instability and fusion were also analyzed. Results At the mean follow-up time of 30.16 months (range, 24–53 months), resolution of spinal infection was achieved in all patients. The mean CRP before surgery was 14.32±7.9 mg/dL, and at the final follow-up, the mean CRP decreased to 0.5±0.33 mg/dL (p <0.005). Follow-up computed tomography scan at 12 months after surgery revealed solid fusion in all patients. The VAS before surgery was 9.16±1.29 and at the final follow-up, it improved to 1.38±2.03, which was statistically significant (p <0.05). Eleven patients out of eighteen (61.11%) with initial neurological impairment had an average improvement of 1.27 grades at the final follow-up documented with the Frankel grading system. Conclusions Posterior screw fixation with titanium instrumentation was safe and effective in terms of stability and restoration of neurological impairment. Fixation also rapidly reduced back pain. PMID:27340525

  1. C1-C2 intra-articular screw fixation for atlantoaxial posterior stabilization.

    PubMed

    Tokuhashi, Y; Matsuzaki, H; Shirasaki, Y; Tateishi, T

    2000-02-01

    A trial of a new posterior stabilization technique for atlantoaxial instability and a report of preliminary results. To describe a new posterior stabilization technique for atlantoxial instability. Magerl's transarticular screw fixation is an accepted technique for rigid atlantoaxial stabilization, which reportedly has yielded many good clinical results. However, the technique is technically demanding and poses a risk of injury to the nerves and veins. Eleven patients who had been treated with intra-articular screw fixation in combination with Halifax interlaminar clamp (OSTEONICS, Allendale, NJ) for atlantoaxial instability were observed. Results of their clinical examinations and biomechanical studies using resinous bones of a cervical spine model were reviewed. In all patients, occipital pain, neck pain, and neural deficit improved, and bony fusion with no correction loss was shown on radiography. To date, no vascular or neural complications have been found, and no instrumentation failures have occurred. In the biomechanical study, the Halifax with transarticular screw fixation had significantly greater flexion stiffness than the Halifax only or the Halifax with intra-articular screw fixation, but the torsion stiffness of the Halifax with intra-articular screw fixation was significantly greater than that of the other Halifax combinations. The preliminary results showed that this technique was effective in strengthening the rotational stability of the atlantoaxial fixation and was considered useful for atlantoaxial posterior stabilization.

  2. Workshop: The Technical Requirements for Image-Guided Therapy (Focus: Spinal Cord and Spinal Column)

    DTIC Science & Technology

    2000-02-01

    degenerative disease, spondylosis , ligamental ossification, fractures, tumors, and other causes. Compression is a painful condition that may require...series of 7000 patients who underwent lumbar disk surgery, Long indicates three reasons for failed surgery: 1. Failure of the patient to meet the...validated outcomes measures in the lumbar area, is used for a 70-year-old patient with osteoarthritis of the knees and low back pain as well as problems

  3. Improving outcome of sensorimotor functions after traumatic spinal cord injury.

    PubMed

    Dietz, Volker

    2016-01-01

    In the rehabilitation of a patient suffering a spinal cord injury (SCI), the exploitation of neuroplasticity is well established. It can be facilitated through the training of functional movements with technical assistance as needed and can improve outcome after an SCI. The success of such training in individuals with incomplete SCI critically depends on the presence of physiological proprioceptive input to the spinal cord leading to meaningful muscle activations during movement performances. Some actual preclinical approaches to restore function by compensating for the loss of descending input to spinal networks following complete/incomplete SCI are critically discussed in this report. Electrical and pharmacological stimulation of spinal neural networks is still in the experimental stage, and despite promising repair studies in animal models, translations to humans up to now have not been convincing. It is possible that a combination of techniques targeting the promotion of axonal regeneration is necessary to advance the restoration of function. In the future, refinement of animal models according to clinical conditions and requirements may contribute to greater translational success.

  4. Spinal Nerve Root Haemangioblastoma Associated with Reactive Polycythemia

    PubMed Central

    Law, Eric K. C.; Lee, Ryan K. L.; Griffith, James F.; Siu, Deyond Y. W.; Ng, Ho Keung

    2014-01-01

    Haemangioblastomas are uncommon tumours that usually occur in the cerebellum and, less commonly, in the intramedullary spinal cord. The extramedullary spinal canal is an uncommon location for these tumours. Also haemangioblastoma at this site is not known to be associated with polycythemia. We present the clinical, imaging, and histological findings of an adult patient with extramedullary spinal haemangioblastoma and reactive polycythemia. Radiography and computed tomography (CT) revealed a medium-sized tumour that most likely arose from an extramedullary spinal nerve root. This tumour appeared to be slow growing as evidenced by the accompanying well-defined bony resorption with a sclerotic rim and mild neural foraminal widening. Magnetic resonance imaging revealed prominent flow voids consistent with tumoural hypervascularity. CT-guided biopsy was performed. Although preoperative angiographic embolisation was technically successful, excessive intraoperative tumour bleeding necessitated tumour debulking rather than complete tumour resection. Histology of the resected specimen revealed haemangioblastoma. Seven months postoperatively, the patients back pain and polycythemia have resolved. PMID:25431722

  5. Anterior cervical fusion with interbody cage containing β-tricalcium phosphate augmented with plate fixation: a prospective randomized study with 2-year follow-up

    PubMed Central

    Jiang, Lei-Sheng

    2008-01-01

    A variety of bone graft substitutes, interbody cages, and anterior plates have been used in cervical interbody fusion, but no controlled study was conducted on the clinical performance of β-tricalcium phosphate (β-TCP) and the effect of supplemented anterior plate fixation. The objective of this prospective, randomized clinical study was to evaluate the effectiveness of implanting interbody fusion cage containing β-TCP for the treatment of cervical radiculopathy and/or myelopathy, and the fusion rates and outcomes in patients with or without randomly assigned plate fixation. Sixty-two patients with cervical radiculopathy and/or myelopathy due to soft disc herniation or spondylosis were treated with one- or two-level discectomy and fusion with interbody cages containing β-TCP. They were randomly assigned to receive supplemented anterior plate (n = 33) or not (n = 29). The patients were followed up for 2 years postoperatively. The radiological and clinical outcomes were assessed during a 2-year follow-up. The results showed that the fusion rate (75.0%) 3 months after surgery in patients treated without anterior cervical plating was significantly lower than that (97.9%) with plate fixation (P < 0.05), but successful bone fusion was achieved in all patients of both groups at 6-month follow-up assessment. Patients treated without anterior plate fixation had 11 of 52 (19.2%) cage subsidence at last follow-up. No difference (P > 0.05) was found regarding improvement in spinal curvature as well as neck and arm pain, and recovery rate of JOA score at all time intervals between the two groups. Based on the findings of this study, interbody fusion cage containing β-TCP following one- or two-level discectomy proved to be an effective treatment for cervical spondylotic radiculopathy and/or myelopathy. Supplemented anterior plate fixation can promote interbody fusion and prevent cage subsidence but do not improve the 2-year outcome when compared with those treated without anterior plate fixation. PMID:18301927

  6. Successful fifth metatarsal bulk autograft reconstruction of thermal necrosis post intramedullary fixation.

    PubMed

    Veljkovic, Andrea; Le, Vu; Escudero, Mario; Salat, Peter; Wing, Kevin; Penner, Murray; Younger, Alastair

    2018-03-21

    Reamed intramedullary (IM) screw fixation for proximal fifth metatarsal fractures is technically challenging with potentially devastating complications if basic principles are not followed. A case of an iatrogenic fourth-degree burn after elective reamed IM screw fixation of a proximal fifth metatarsal fracture in a high-level athlete is reported. The case was complicated by postoperative osteomyelitis with third-degree soft-tissue defect. This was successfully treated with staged autologous bone graft reconstruction, tendon reconstruction, and local bi-pedicle flap coverage. The patient returned to competitive-level sports, avoiding the need for fifth ray amputation. Critical points of the IM screw technique and definitive reconstruction are discussed. Bulk autograft reconstruction is a safe and effective alternative to ray amputation in segmental defects of the fifth metatarsal.Level of evidence V.

  7. Etiology of lumbar lordosis and its pathophysiology: a review of the evolution of lumbar lordosis, and the mechanics and biology of lumbar degeneration.

    PubMed

    Sparrey, Carolyn J; Bailey, Jeannie F; Safaee, Michael; Clark, Aaron J; Lafage, Virginie; Schwab, Frank; Smith, Justin S; Ames, Christopher P

    2014-05-01

    The goal of this review is to discuss the mechanisms of postural degeneration, particularly the loss of lumbar lordosis commonly observed in the elderly in the context of evolution, mechanical, and biological studies of the human spine and to synthesize recent research findings to clinical management of postural malalignment. Lumbar lordosis is unique to the human spine and is necessary to facilitate our upright posture. However, decreased lumbar lordosis and increased thoracic kyphosis are hallmarks of an aging human spinal column. The unique upright posture and lordotic lumbar curvature of the human spine suggest that an understanding of the evolution of the human spinal column, and the unique anatomical features that support lumbar lordosis may provide insight into spine health and degeneration. Considering evolution of the skeleton in isolation from other scientific studies provides a limited picture for clinicians. The evolution and development of human lumbar lordosis highlight the interdependence of pelvic structure and lumbar lordosis. Studies of fossils of human lineage demonstrate a convergence on the degree of lumbar lordosis and the number of lumbar vertebrae in modern Homo sapiens. Evolution and spine mechanics research show that lumbar lordosis is dictated by pelvic incidence, spinal musculature, vertebral wedging, and disc health. The evolution, mechanics, and biology research all point to the importance of spinal posture and flexibility in supporting optimal health. However, surgical management of postural deformity has focused on restoring posture at the expense of flexibility. It is possible that the need for complex and costly spinal fixation can be eliminated by developing tools for early identification of patients at risk for postural deformities through patient history (genetics, mechanics, and environmental exposure) and tracking postural changes over time.

  8. [Diagnostic and Treatment Strategies in Morel-Lavallee Lesions in the Spinal Column and Pelvis].

    PubMed

    Becker, Christopher A; Kammerlander, Christian; Greiner, Axel; Sommer, Fabian; Linhart, Christoph; Böcker, Wolfgang; Rubenbauer, Bianka; Weidert, Simon

    2018-04-12

    The Morel-Lavallée lesion is one of the concomitant soft tissue lesions of pelvic fractures. Its role in spine fractures and its treatment in combination with osteosynthesis of pelvic or spine fractures have not yet been determined. The aim of this study was to analyse the best diagnostic and treatment options of both spine and pelvic fractures combined with Morel-Lavallée lesions (MLL). An analysis of the literature was performed via PubMed and Medline. This revealed a total of 197 studies and case reports. After analysing the literature, 19 studies/case reports met our inclusion criteria. There are several diagnostic options for MLL, including ultrasound, computed tomography or MRI. In spinal and pelvic lesions, ultrasound is capable of detecting MLL. Some authors tend to perform open debridement of the MLL, whereas others recommend percutanous treatment. Open debridement and vacuum-assisted closure are recommended in late diagnosed MLL, where primary suture of the soft tissue is impossible. Fracture fixation should be performed simultaneously to treatment of the MLL. Broad-spectrum cephalosporins combined with an aminoglycoside or piperacilline/tazobactam should be initiated. Radical debridement and drainage are recommended, especially when MLL is diagnosed late. Repeated ultrasound examinations should be performed of the surrounding soft tissue of the fracture. When MLL is diagnosed within 2 days, percutanous fracture and MLL treatment should be performed. After more than 2 days, both fracture and MLL should be treated with open debridement, open fracture fixation and primary suture if possible. Georg Thieme Verlag KG Stuttgart · New York.

  9. Impact of case type, length of stay, institution type, and comorbidities on Medicare diagnosis-related group reimbursement for adult spinal deformity surgery.

    PubMed

    Nunley, Pierce D; Mundis, Gregory M; Fessler, Richard G; Park, Paul; Zavatsky, Joseph M; Uribe, Juan S; Eastlack, Robert K; Chou, Dean; Wang, Michael Y; Anand, Neel; Frank, Kelly A; Stone, Marcus B; Kanter, Adam S; Shaffrey, Christopher I; Mummaneni, Praveen V

    2017-12-01

    OBJECTIVE The aim of this study was to educate medical professionals about potential financial impacts of improper diagnosis-related group (DRG) coding in adult spinal deformity (ASD) surgery. METHODS Medicare's Inpatient Prospective Payment System PC Pricer database was used to collect 2015 reimbursement data for ASD procedures from 12 hospitals. Case type, hospital type/location, number of operative levels, proper coding, length of stay, and complications/comorbidities (CCs) were analyzed for effects on reimbursement. DRGs were used to categorize cases into 3 types: 1) anterior or posterior only fusion, 2) anterior fusion with posterior percutaneous fixation with no dorsal fusion, and 3) combined anterior and posterior fixation and fusion. RESULTS Pooling institutions, cases were reimbursed the same for single-level and multilevel ASD surgery. Longer stay, from 3 to 8 days, resulted in an additional $1400 per stay. Posterior fusion was an additional $6588, while CCs increased reimbursement by approximately $13,000. Academic institutions received higher reimbursement than private institutions, i.e., approximately $14,000 (Case Types 1 and 2) and approximately $16,000 (Case Type 3). Urban institutions received higher reimbursement than suburban institutions, i.e., approximately $3000 (Case Types 1 and 2) and approximately $3500 (Case Type 3). Longer stay, from 3 to 8 days, increased reimbursement between $208 and $494 for private institutions and between $1397 and $1879 for academic institutions per stay. CONCLUSIONS Reimbursement is based on many factors not controlled by surgeons or hospitals, but proper DRG coding can significantly impact the financial health of hospitals and availability of quality patient care.

  10. Endoscopic suture fixation is associated with reduced migration of esophageal fully covered self-expandable metal stents (FCSEMS).

    PubMed

    Wright, Andrew; Chang, Andrew; Bedi, Aarti Oza; Wamsteker, Erik-Jan; Elta, Grace; Kwon, Richard S; Carrott, Phillip; Elmunzer, B Joseph; Law, Ryan

    2017-09-01

    Esophageal fully covered self-expandable metal stents (FCSEMS) are indicated for the management of benign and malignant conditions of the esophagus including perforations, leaks, and strictures. FCSEMS are resistant to tissue ingrowth and are removable; however, stent migration occurs in 30-55% of cases. Endoscopic suture fixation of FCSEMS has been utilized to decrease the risk of stent migration though data supporting this practice remain limited. The primary aim of this study was to compare clinical outcomes and migration rate of patients who underwent placement of esophageal FCSEMS with and without endoscopic suture fixation. Our single-center, retrospective, cohort study includes patients who underwent esophageal FCSEMS placement with and without endoscopic suture fixation between January 1, 2012, and November 11, 2015. Baseline patient characteristics, procedural details, and clinical outcomes were abstracted. Logistic regression was performed to identify clinical and technical factors associated with outcomes and stent migration. A total of 51 patients underwent 62 FCSEMS placements, including 21 procedures with endoscopic suture fixation and 41 without. Suture fixation was associated with reduced risk of stent migration (OR 0.13, 95% CI 0.03-0.47). Prior stent migration was associated with significantly higher risk of subsequent migration (OR 6.4, 95% CI 1.6-26.0). Stent migration was associated with lower likelihood of clinical success (OR 0.21, 95% CI 0.06-0.69). There was a trend toward higher clinical success among patients undergoing suture fixation (85.7 vs. 60.9%, p = 0.07). Endoscopic suture fixation of FCSEMS was associated with a reduced stent migration rate. Appropriate patient selection for suture fixation of FCSEMS may lead to reduced migration in high-risk patients.

  11. The effect of bone tunnel dilation versus extraction drilling on the initial fixation strength of press-fit anterior cruciate ligament reconstruction.

    PubMed

    Dargel, Jens; Schmidt-Wiethoff, Rüdiger; Brüggemann, Gert-Peter; Koebke, Jürgen

    2007-11-01

    Serial dilation of the bone tunnel has been reported to create a tighter graft-tunnel fit. It was hypothesized that a serial dilation of the femoral bone tunnel would increase the initial fixation strength in press-fit anterior cruciate ligament (ACL) reconstructive surgery. Initial fixation strength of the femoral press-fit fixation technique was investigated in 72 porcine specimens in an ex vivo study by varying the femoral tunnel preparation technique. Extraction-drilling, tunnel dilation by 1 mm and dilation by 2.5 mm were assessed. Initial fixation strength of press-fit fixated patellar tendon-bone grafts was tested within each preparation group conducting a single cycle (and cyclic) load to failure protocol. The resulting tunnel diameter and the porcine femoral bone mineral density were determined using microradiographs and peripheral quantitative CT scans, respectively. Dilating a previously extraction-drilled femoral bone tunnel by 1 mm significantly enhances initial press-fit fixation strength in both single cycle and cyclic load to failure testing when compared to extraction-drilling and tunnel dilation by 2.5 mm. Due to an initial spring-back effect the resulting diameter of the femoral tunnel was underestimated by 3.3% with drilling and 6.7 and 12.2% with dilation by 1 and 2.5 mm, respectively. Volumetric trabecular bone mineral density at the site corresponding to the area of tunnel placement averaged 318 mg/cm(3). Dilating a femoral tunnel that is underdrilled by 1 mm appears to be a reasonable technical procedure in order to enhance initial fixation strength of press-fit ACL graft fixation.

  12. The Postdural Puncture Headache and Back Pain: The Comparison of 26-gauge Atraucan and 26-gauge Quincke Spinal Needles in Obstetric Patients.

    PubMed

    Akdemir, Mehmet Salim; Kaydu, Ayhan; Yanlı, Yonca; Özdemir, Mehtap; Gökçek, Erhan; Karaman, Haktan

    2017-01-01

    The postdural puncture headache (PDPH) and postdural puncture backache (PDPB) are well-known complications of spinal anesthesia. There are some attempts to reduce the frequency of complication such as different design of the spinal needles. The primary outcome of this study is to compare the incidence of PDPH between 26-gauge Atraucan and 26-gauge Quincke spinal needles in elective cesarean operations. The severity of symptoms, the incidence of backache, technical issues, and comparison of cost of needles are secondary outcomes. After Investigational Review Board approval, a randomized, prospective, double-blinded study was designed in 682 American Society of Anesthesiologists I-II women having elective cesarean operations under spinal anesthesia. Patients were divided into two groups as 26-gauge Atraucan Group A ( n = 323) and 26-gauge Quincke spinal needles Group Q ( n = 342). All patients were questioned about backache 1 week later. Differences between categorical variables were evaluated with Chi-square test. Continuous variables were compared by Student's t -test for two independent groups. A two-sided P < 0.05 was considered statistically significant for all analyses. There were no significant differences between groups in all demographic data. The one attempt success rate of the dural puncture in Group A (70,58%) and in Group Q (69.3%) was similar ( P > 0.05). The incidence of PDPH was 6.5% in Group A and 4.9% in Group Q ( P > 0.05). The epidural blood patch was performed to the three patients in Group A and five patients in Group Q who had severe headache ( P > 0.05). The incidence of PDPB was 4.33% versus 2.04% in Group A and Group Q ( P > 0.05). The incidence of complication rates and technical handling characteristics did not differ between two groups. Quincke needle is cheaper than Atracaun needle, so it can be a cost-effective choice in obstetric patients.

  13. The Postdural Puncture Headache and Back Pain: The Comparison of 26-gauge Atraucan and 26-gauge Quincke Spinal Needles in Obstetric Patients

    PubMed Central

    Akdemir, Mehmet Salim; Kaydu, Ayhan; Yanlı, Yonca; Özdemir, Mehtap; Gökçek, Erhan; Karaman, Haktan

    2017-01-01

    Background: The postdural puncture headache (PDPH) and postdural puncture backache (PDPB) are well-known complications of spinal anesthesia. There are some attempts to reduce the frequency of complication such as different design of the spinal needles. Aims: The primary outcome of this study is to compare the incidence of PDPH between 26-gauge Atraucan and 26-gauge Quincke spinal needles in elective cesarean operations. The severity of symptoms, the incidence of backache, technical issues, and comparison of cost of needles are secondary outcomes. Materials and Methods: After Investigational Review Board approval, a randomized, prospective, double-blinded study was designed in 682 American Society of Anesthesiologists I–II women having elective cesarean operations under spinal anesthesia. Patients were divided into two groups as 26-gauge Atraucan Group A (n = 323) and 26-gauge Quincke spinal needles Group Q (n = 342). All patients were questioned about backache 1 week later. Differences between categorical variables were evaluated with Chi-square test. Continuous variables were compared by Student's t-test for two independent groups. A two-sided P < 0.05 was considered statistically significant for all analyses. Results: There were no significant differences between groups in all demographic data. The one attempt success rate of the dural puncture in Group A (70,58%) and in Group Q (69.3%) was similar (P > 0.05). The incidence of PDPH was 6.5% in Group A and 4.9% in Group Q (P > 0.05). The epidural blood patch was performed to the three patients in Group A and five patients in Group Q who had severe headache (P > 0.05). The incidence of PDPB was 4.33% versus 2.04% in Group A and Group Q (P > 0.05). Conclusions: The incidence of complication rates and technical handling characteristics did not differ between two groups. Quincke needle is cheaper than Atracaun needle, so it can be a cost-effective choice in obstetric patients. PMID:28663641

  14. Vasoactive intestinal peptide and electrical activity influence neuronal survival

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brenneman, D.E.; Eiden, L.E.

    1986-02-01

    Blockage of electrical activity in dissociated spinal cord cultures results in a significant loss of neurons during a critical period in development. Decreases in neuronal cell numbers and SVI-labeled tetanus toxin fixation produced by electrical blockage with tetrodotoxin (TTX) were prevented by addition of vasoactive intestinal peptide (VIP) to the nutrient medium. The most effective concentration of VIP was 0.1 nM. At higher concentrations, the survival-enhancing effect of VIP on TTX-treated cultures was attenuated. Addition of the peptide alone had no significant effect on neuronal cell counts or tetanus toxin fixation. With the same experimental conditions, two closely related peptides,more » PHI-27 (peptide, histidyl-isoleucine amide) and secretin, were found not to increase the number of neurons in TTX-treated cultures. Interference with VIP action by VIP antiserum resulted in neuronal losses that were not significantly different from those observed after TTX treatment. These data indicate that under conditions of electrical blockade a neurotrophic action of VIP on neuronal survival can be demonstrated.« less

  15. Aggressive vertebral hemangioma of the thoracic spine without typical radiological appearance.

    PubMed

    Dang, Lei; Liu, Chen; Yang, Shao Min; Jiang, Liang; Liu, Zhong Jun; Liu, Xiao Guang; Yuan, Hui Shu; Wei, Feng; Yu, Miao

    2012-10-01

    Vertebral hemangioma (VH) is virtually vascular malformation, which is usually asymptomatic. Only 3.7 % of VH may become active and symptomatic, and 1 % may invade the spinal canal and/or paravertebral space. Treatment protocols for active or aggressive VHs are still in controversy. Reported treatments include radiotherapy, vertebroplasty, direct alcohol injection, embolization, surgery and a combination of these modalities. A 41-year-old lady was presented with 18 month history of intermittent back pain. CT revealed T5 osteolytic lesion with epidural and paravertebral extension. The first CT guided biopsy yielded little information. Histopathological diagnosis of the second biopsy was VH. Vertebroplasty, posterior decompression and fixation were performed followed by postoperative radiotherapy. Her symptoms were resolved immediately after the operation. At 12 months follow-up, no recurrence was detected by CT with contrast enhancement. Surgical decompression, vertebroplasty and fixation are safe and effective for aggressive VH. More attention is needed in determining the algorithm for the diagnosis and treatment of aggressive VH.

  16. A novel approach for assigning levels to monkey and human lumbosacral spinal cord based on ventral horn morphology

    PubMed Central

    Gross, Cassandra; Ellison, Brian; Buchman, Aron S.; Terasawa, Ei

    2017-01-01

    Proper identification of spinal cord levels is crucial for clinical-pathological and imaging studies in humans, but can be a challenge given technical limitations. We have previously demonstrated in non-primate models that the contours of the spinal ventral horn are determined by the position of motoneuron pools. These positions are preserved within and among individuals and can be used to identify lumbosacral spinal levels. Here we tested the hypothesis that this approach can be extended to identify monkey and human spinal levels. In 7 rhesus monkeys, we retrogradely labeled motoneuron pools that represent rostral, middle and caudal landmarks of the lumbosacral enlargement. We then aligned the lumbosacral enlargements among animals using absolute length, segmental level or a relative scale based upon rostral and caudal landmarks. Inter-animal matching of labeled motoneurons across the lumbosacral enlargement was most precise when using internal landmarks. We then reconstructed 3 human lumbosacral spinal cords, and aligned these based upon homologous internal landmarks. Changes in shape of the ventral horn were consistent among human subjects using this relative scale, despite marked differences in absolute length or age. These data suggest that the relative position of spinal motoneuron pools is conserved across species, including primates. Therefore, in clinical-pathological or imaging studies in humans, one can assign spinal cord levels to even single sections by matching ventral horn shape to standardized series. PMID:28542213

  17. Minimally Invasive 2D Navigation-Assisted Treatment of Thoracolumbar Spinal Fractures in East Africa: A Case Report

    PubMed Central

    Njoku, Innocent; Wanin, Othman; Assey, Anthony; Shabani, Hamisi; Ngerageza, Japhet G; Berlin, Connor D

    2016-01-01

    Spinal surgery under Eastern-African circumstances is technically demanding and associated with significant complications, such as blood loss, infection, and wound breakdown. We report a spinal trauma case that was performed using minimally invasive surgery (MIS) and navigation, and hypothesize that these newer techniques may enable surgeons to perform effective spinal surgery with minimal complications and good outcomes.  During the 2014 First Hands-on Neurotrauma Course held in Dar es Salaam, Tanzania, we successfully performed three minimally invasive and two-dimensional (2D) navigated spinal surgeries to decompress and stabilize patients with complete and incomplete spinal injuries. In this report, we present a case of a paraplegic patient with a T12 burst fracture who tolerated MIS surgery with no intraoperative complications, and is doing well with no postoperative complications one year after surgery. Minimally invasive spinal surgery and 2D navigation may offer advantages in resource-poor countries. As part of the Weill Cornell Tanzania Neurosurgery project and in conjunction with the Foundation for International Education in Neurological Surgery (as well as other organizations), further experiences with 2D navigation and MIS surgery will be recorded in 2015. A neurotrauma registry has already been implemented to better understand the current management of neurotrauma in Eastern Africa. PMID:27026832

  18. Spinal Anesthesia and Minimal Invasive Laminotomy for Paddle Electrode Placement in Spinal Cord Stimulation: Technical Report and Clinical Results at Long-Term Followup

    PubMed Central

    Sarubbo, S.; Latini, F.; Tugnoli, V.; Quatrale, R.; Granieri, E.; Cavallo, M. A.

    2012-01-01

    Object. We arranged a mini-invasive surgical approach for implantation of paddle electrodes for SCS under spinal anesthesia obtaining the best paddle electrode placement and minimizing patients' discomfort. We describe our technique supported by neurophysiological intraoperative monitoring and clinical results. Methods. 16 patients, affected by neuropathic pain underwent the implantation of paddle electrodes for spinal cord stimulation in lateral decubitus under spinal anesthesia. The paddle was introduced after flavectomy and each patient confirmed the correct distribution of paresthesias induced by intraoperative test stimulation. VAS and patients' satisfaction rate were recorded during the followup and compared to preoperative values. Results. No patients reported discomfort during the procedure. In all cases, paresthesias coverage of the total painful region was achieved, allowing the best final electrode positioning. At the last followup (mean 36.7 months), 87.5% of the implanted patients had a good rate of satisfaction with a mean VAS score improvement of 70.5%. Conclusions. Spinal cord stimulation under spinal anesthesia allows an optimal positioning of the paddle electrodes without any discomfort for patients or neurosurgeons. The best intraoperative positioning allows a better postoperative control of pain, avoiding the risk of blind placements of the paddle or further surgery for their replacement. PMID:22566761

  19. Spinal Anesthesia in Infant Rats: Development of a Model and Assessment of Neurological Outcomes

    PubMed Central

    Yahalom, Barak; Athiraman, Umeshkumar; Soriano, Sulpicio G.; Zurakowski, David; Carpino, Elizabeth; Corfas, Gabriel; Berde, Charles B.

    2012-01-01

    Background Previous studies in infant rats and case-control studies of human infants undergoing surgery have raised concerns about potential neurodevelopmental toxicities of general anesthesia. Spinal anesthesia is an alternative to general anesthesia for some infant surgeries. To test for potential toxicity, we developed a spinal anesthesia model in infant rats. Methods Rats of postnatal ages 7, 14, and 21 days were assigned to: no treatment; 1% isoflurane for either 1 h or 6 h, or lumbar spinal injection of saline or bupivacaine, at doses of 3.75 mg/kg (low dose) or 7.5 mg/kg (high dose). Subgroups of animals underwent neurobehavioral testing and blood gas analysis. Brain and lumbar spinal cord sections were examined for apoptosis using cleaved caspase-3 immunostaining. Lumbar spinal cord was examined histologically. Rats exposed to spinal or general anesthesia as infants underwent Rotarod testing of motor performance as adults. Data were analyzed using analysis of variance (ANOVA) using general linear models, Friedman Tests, and Mann–Whitney U tests, as appropriate. Results Bupivacaine 3.75 mg/kg was effective for spinal anesthesia in all age groups, and produced sensory and motor function recovered in 40 to 60 min. Blood gases were similar among groups. Brain and spinal cord apoptosis increased in rats receiving 6 h of 1% isoflurane, but not among the other treatments. All groups showed intact motor performance at adulthood. Conclusions Spinal anesthesia is technically feasible in infant rats, and appears benign in terms of neuroapoptotic and neuromotor sequelae. PMID:21555934

  20. Vertebral column resection for the treatment of severe spinal deformity.

    PubMed

    Lenke, Lawrence G; Sides, Brenda A; Koester, Linda A; Hensley, Marsha; Blanke, Kathy M

    2010-03-01

    The ability to treat severe pediatric and adult spinal deformities through an all-posterior vertebral column resection (VCR) has obviated the need for a circumferential approach in primary and revision surgery, but there is limited literature evaluating this new approach. Our purpose was therefore to provide further support of this technique. We reviewed 43 patients who underwent a posterior-only VCR using pedicle screws, anteriorly positioned cages, and intraoperative spinal cord monitoring between 2002 and 2006. Diagnoses included severe scoliosis, global kyphosis, angular kyphosis, or kyphoscoliosis. Forty (93%) procedures were performed at L1 or cephalad in the spinal cord (SC) territory. Seven patients (18%) lost intraoperative neurogenic monitoring evoked potentials (NMEPs) data during correction with data returning to baseline after prompt surgical intervention. All patients after surgery were at their baseline or showed improved SC function, whereas no one worsened. Two patients had nerve root palsies postoperatively, which resolved spontaneously at 6 months and 2 weeks. Spinal cord monitoring (specifically NMEP) is mandatory to prevent neurologic complications. Although technically challenging, a single-stage approach offers dramatic correction in both primary and revision surgery of severe spinal deformities. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  1. Topologically preserving straightening of spinal cord MRI.

    PubMed

    De Leener, Benjamin; Mangeat, Gabriel; Dupont, Sara; Martin, Allan R; Callot, Virginie; Stikov, Nikola; Fehlings, Michael G; Cohen-Adad, Julien

    2017-10-01

    To propose a robust and accurate method for straightening magnetic resonance (MR) images of the spinal cord, based on spinal cord segmentation, that preserves spinal cord topology and that works for any MRI contrast, in a context of spinal cord template-based analysis. The spinal cord curvature was computed using an iterative Non-Uniform Rational B-Spline (NURBS) approximation. Forward and inverse deformation fields for straightening were computed by solving analytically the straightening equations for each image voxel. Computational speed-up was accomplished by solving all voxel equation systems as one single system. Straightening accuracy (mean and maximum distance from straight line), computational time, and robustness to spinal cord length was evaluated using the proposed and the standard straightening method (label-based spline deformation) on 3T T 2 - and T 1 -weighted images from 57 healthy subjects and 33 patients with spinal cord compression due to degenerative cervical myelopathy (DCM). The proposed algorithm was more accurate, more robust, and faster than the standard method (mean distance = 0.80 vs. 0.83 mm, maximum distance = 1.49 vs. 1.78 mm, time = 71 vs. 174 sec for the healthy population and mean distance = 0.65 vs. 0.68 mm, maximum distance = 1.28 vs. 1.55 mm, time = 32 vs. 60 sec for the DCM population). A novel image straightening method that enables template-based analysis of quantitative spinal cord MRI data is introduced. This algorithm works for any MRI contrast and was validated on healthy and patient populations. The presented method is implemented in the Spinal Cord Toolbox, an open-source software for processing spinal cord MRI data. 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1209-1219. © 2017 International Society for Magnetic Resonance in Medicine.

  2. PEEK Biomaterials in Trauma, Orthopedic, and Spinal Implants

    PubMed Central

    Kurtz, S. M.; Devine, J. N.

    2007-01-01

    Since the 1980s, polyaryletherketones (PAEKs) have been increasingly employed as biomaterials for trauma, orthopedic, and spinal implants. We have synthesized the extensive polymer science literature as it relates to structure, mechanical properties, and chemical resistance of PAEK biomaterials. With this foundation, one can more readily appreciate why this family of polymers will be inherently strong, inert, and biocompatible. Due to its relative inertness, PEEK biomaterials are an attractive platform upon which to develop novel bioactive materials, and some steps have already been taken in that direction, with the blending of HA and TCP into sintered PEEK. However, to date, blended HA-PEEK composites have involved a trade-off in mechanical properties in exchange for their increased bioactivity. PEEK has had the greatest clinical impact in the field of spine implant design, and PEEK is now broadly accepted as a radiolucent alternative to metallic biomaterials in the spine community. For mature fields, such as total joint replacements and fracture fixation implants, radiolucency is an attractive but not necessarily critical material feature. PMID:17686513

  3. Sequence of Tissue Responses in the Early Stages of Experimental Allergic Encephalomyelitis (EAE): Immunohistochemical, Light Microscopic, and Ultrastructural Observations in the Spinal Cord

    NASA Technical Reports Server (NTRS)

    DAmelio, Fernando E.; Smith, Marion E.; Eng, Lawrence F.

    1990-01-01

    Experimental allergic encephalomyelitis (EAE) was induced in adult Lewis rats with purified guinea pig CNS myelin and Freund's adjuvant. As soon as the very earliest clinical signs appeared the animals were perfused with fixatives and the spinal cord analyzed by electron microscopy, silver methods, and immunocytochemistry. Our findings suggest that in the early stages of EAE a sequence of events can be traced, although these events frequently overlap. The earliest morphological change appears to be astrocytic edema in both the cell body and processes. Increased amounts of glycogen particles and dispersion of glial filaments are prominent. These changes seem to occur just prior to the time when inflammatory cells begin to penetrate the capillary walls. Invasion of the neuropil mainly by macrophages and lymphocytes closely follows. Both macrophages and microglia seem to participate in phagocytosis of oligodendrocytes and myelin. Demyelination, however, is not a prominent feature at this early stage.

  4. Improving proximal fixation and seal with the HeliFx Aortic EndoAnchor.

    PubMed

    Deaton, David H

    2012-12-01

    Endovascular aneurysm repair (EVAR) transformed the therapy for aortic aneurysms and introduced an era of widespread use for endovascular procedures in a variety of vascular beds. Although dramatic improvements in acute outcomes drove the early enthusiasm for EVAR, a realization that the long-term integrity of the endoprostheses used for EVAR were sometimes inferior to the results obtained with open surgical reconstruction dampened enthusiasm for their use in low-risk and younger patients who mandated long-term follow-up. While early EVAR failure modes are often related to technical aspects of the implantation, late failures are often related to the implant migrating from its original longitudinal position or losing wall apposition in the face of continued aneurysmal dilatation. Migration, or the failure of longitudinal fixation, results in gradual loss of aortic approximation and the eventual repressurization of the aneurysm sac with its attendant risks of growth and rupture. The inability of stent- and barb-based endovascular fixation to resist aortic dilatation at the site of fixation also represents a late failure mode that can result in aneurysm rupture. A variety of endostaples or endoanchors designed to replicate the function of an interrupted aortic suture have been proposed and tested to varying degrees over the years. The device designed and produced by Aptus EndoSystems, now called the HeliFx Aortic EndoAnchor is the only independent endovascular fixation device that has achieved significant clinical usage and Food and Drug Administration approval. The experience with this device is now more than 5 years and it is approved for use in the broad market across both Europe and the United States. This article will review the engineering and design concepts underlying the HeliFx device as well as the in vitro and in vivo results using this device. Finally, a discussion of the potential for technical, procedural, and endograft innovation based on the availability of endovascular suturing will be reviewed. Copyright © 2012. Published by Elsevier Inc.

  5. Decision making in surgical treatment of chronic low back pain: the performance of prognostic tests to select patients for lumbar spinal fusion.

    PubMed

    Willems, Paul

    2013-02-01

    Chronic low back pain (CLBP) is one of the main causes of disability in the western world with a huge economic burden to society. As yet, no specific underlying anatomic cause has been identified for CLBP. Imaging often reveals degenerative findings of the disc or facet joints of one or more lumbar motion segments. These findings, however, can also be observed in asymptomatic people. It has been suggested that pain in degenerated discs may be caused by the ingrowth of nerve fibers into tears or clefts of the annulus fibrosus or nucleus pulposus, and by reported high levels of pro-inflammatory mediators. As this so-called discogenic pain is often exacerbated by mechanical loading, the concept of relieving pain by spinal fusion to stabilise a painful spinal segment, has been developed. For some patients lumbar spinal fusion indeed is beneficial, but its results are highly variable and hard to predict for the individual patient. To identify those CLBP patients who will benefit from fusion, many surgeons rely on tests that are assumed to predict the outcome of spinal fusion. The three most commonly used prognostic tests in daily practice are immobilization in a lumbosacral orthosis, provocative discography and trial immobilization by temporary external transpedicular fixation. Aiming for consensus on the indications for lumbar fusion and in order to improve its results by better patient selection, it is essential to know the role and value of these prognostic tests for CLBP patients in clinical practice. The overall aims of the present thesis were: 1) to evaluate whether there is consensus among spine surgeons regarding the use and appreciation of prognostic tests for lumbar spinal fusion; 2) to verify whether a thoracolumbosacral orthosisis (TLSO) truly minimises lumbosacral motion; 3) to verify whether a TLSO can predict the clinical outcome of fusion for CLBP; 4) to assess whether provocative discography of adjacent segments actually predicts the long-term clinical outcome fusion; 5) to determine the incidence of postdiscography discitis, and whether there is a need for routine antibiotic prophylaxis; 6) to assess whether temporary external transpedicular fixation (TETF) can help to predict the outcome of spinal fusion; 7) to determine the prognostic accuracy of the most commonly used tests in clinical practice to predict the outcome of fusion for CLBP. The results of a national survey among spine surgeons in the Netherlands were presented in Study I. The surgeons were questioned about their opinion on prognostic factors and about the use of predictive tests for lumbar fusion in CLBP patients. The comments were compared with findings from the prevailing literature. The survey revealed a considerable lack of uniformity in the use and appreciation of predictive tests. Prognostic factors known from the literature were not consistently incorporated in the surgeons' decision making process either. This heterogeneity in strategy is most probably caused by the lack of sound scientific evidence for current predictive tests and it was concluded that currently there is not enough consensus among spine surgeons in the Netherlands to create national guidelines for surgical decision making in CLBP. In Study II, the hypothesized working mechanism of a pantaloon cast (i.e., minimisation of lumbosacral joint mobility) was studied. In patients who were admitted for a temporary external transpedicular fixation test (TETF), infrared light markers were rigidly attached to the protruding ends of Steinman pins that were fixed in two spinal levels. In this way three-dimensional motion between these levels could be analysed opto-electronically. During dynamic test conditions such as walking, a plaster cast, either with or without unilateral hip fixation, did not significantly decrease lumbosacral joint motion. Although not substantiated by sound scientific support, lumbosacral orthoses or pantaloon casts are often used in everyday practice as a predictor for the outcome of fusion. A systematic review of the literature supplemented with a prospective cohort study was performed (Study III) in order to assess the value of a pantaloon cast in surgical decision-making. It appeared that only in CLBP patients with no prior spine surgery, a pantaloon cast test with substantial pain relief suggests a favorable outcome of lumbar fusion compared to conservative treatment. In patients with prior spine surgery the test is of no value. It is believed by many spine surgeons that provocative discography, unlike plain radiographs or magnetic resonance imaging, is a physiologic test that can truly determine whether a disc is painful and relevant in a patient's pain syndrome, irrespective of the morphology of the disc. It has been suggested that in order to achieve a successful clinical outcome of lumbar fusion, suspect discs should be painful and adjacent control discs should elicit no pain on provocative discography. For this reason, a cohort of patients in whom the decision to perform lumbar fusion was based on an external fixation (TETF) trial, was analysed retrospectively in Study IV. The results of preoperative discography of solely the levels adjacent to the fusion were compared with the clinical results after spinal fusion. It appeared that in this select group of patients the discographic status of discs adjacent to a lumbar fusion did not have any effect on the clinical outcome. The most feared complication of lumbar discography is discitis. Although low in incidence, this is a serious complication for a diagnostic procedure and prevention by the use of prophylactic antibiotics has been advocated. In search for clinical guidelines, the risk of postdiscography discitis was assessed in Study V by means of a systematic literature review and a cohort of 200 consecutive patients. Without the use of prophylactic antibiotics, an overall incidence of postdiscography discitis of 0.25% was found. To prove that antibiotics would actually prevent discitis, a randomised trial of 9,000 patients would be needed to reach significance. Given the possible adverse effects of antibiotics, it was concluded that the routine use of prophylactic antibiotics in lumbar discography is not indicated. In Study VI, the middle- and long-term results of external fixation (TETF) as a test to predict the clinical outcome of lumbar fusion were studied in a group of back pain patients for whom there was doubt about the indication for surgery. The test included a placebo trial, in which the patients were unaware whether the lumbar segmental levels were fixed or dynamised. Using strict and objective criteria of pain reduction on a visual analogue scale, the TETF test failed to predict clinical outcome of fusion in this select group of patients. Pin track infection and nerve root irritation were registered as complications of this invasive test. It was concluded that in chronic low back pain patients with a doubtful indication for fusion, TETF is not recommended as a supplemental tool for surgical decision-making. In Study VII, a systematic literature review was performed regarding the prognostic accuracy of tests that are currently used in clinical practice and that are presumed to predict the outcome of lumbar spinal fusion for CLBP. The tests of interest were magnetic resonance imaging (MRI), TLSO immobilisation, TETF, provocative discography and facet joint infiltration. Only 10 studies reporting on three different index tests (discography, TLSO immobilisation and TETF) that truly reported on test qualifiers, such as sensitivity, specificity and likelihood ratios, could be selected. It appeared that the accuracy of all prognostic tests was low, which confirmed that in many clinical practices patients are scheduled for fusion on the basis of tests, of which the accuracy is insufficient or at best unknown. As the overall methodological quality of included studies was poor, higher quality trials that include negatively tested as well as positively tested patients for fusion, will be needed. It was concluded that at present, best evidence does not support the use of any prognostic test in clinical practice. No subset of patients with low back pain could be identified, for whom spinal fusion is a reliable and effective treatment. In literature, several studies have reported that cognitive behavioural therapy or intensive exercise programs have treatment results similar to those of spinal fusion, but with considerably less complications, morbidity and costs. As the findings of the present thesis show that the currently used tests do not improve the results of fusion by better patient selection, these tests should not be recommended for surgical decision making in standard care. Moreover, spinal fusion should not be proposed as a standard treatment for chronic low back pain. Causality of nonspecific spinal pain is complex and CLBP should not be regarded as a diagnosis, but rather as a symptom in patients with different stages of impairment and disability. Patients should be evaluated in a multidisciplinary setting or Spine Centre according to the so-called biopsychosocial model, which aims to identify underlying psychosocial factors as well as biological factors. Treatment should occur in a stepwise fashion starting with the least invasive treatment. The current approach of CLBP, in which emphasis is laid on self-management and empowerment of patients to take an active course of treatment in order to prevent long-term disability and chronicity, is recommended.

  6. [Evaluation of radiation exposure of personnel in an orthopaedic and trauma operation theatre using the new real-time dosimetry system "dose aware"].

    PubMed

    Müller, M C; Strauss, A; Pflugmacher, R; Nähle, C P; Pennekamp, P H; Burger, C; Wirtz, D C

    2014-08-01

    There is a positive correlation between operation time and staff exposure to radiation during intraoperative use of C-arm fluoroscopy. Due to harmful effects of exposure to long-term low-dose radiation for both the patient and the operating team it should be kept to a minimum. AIM of this study was to evaluate a novel dosimeter system called Dose Aware® (DA) enabling radiation exposure feedback of the personal in an orthopaedic and trauma operation theatre in real-time. Within a prospective study over a period of four month, DA was applied by the operation team during 104 orthopaedic and trauma operations in which the C-arm fluoroscope was used in 2D-mode. During ten operation techniques, radiation exposure of the surgeon, the first assistant, the theatre nurse and the anaesthesiologist was evaluated. Seventy-three operations were analysed. The surgeon achieved the highest radiation exposure during dorsolumbar spinal osteosynthesis, kyphoplasty and screw fixation of sacral fractures. The first assistant received a higher radiation exposure compared to the surgeon during plate osteosynthesis of distal radius fractures (157 %), intramedullary nailing of pertrochanteric fractures (143 %) and dorsolumbar spinal osteosynthesis (240 %). During external fixation of ankle fractures (68 %) and screw fixation of sacral fractures (66 %) radiation exposure of the theatre nurse exceeded 50 % of the surgeon's radiation exposure. During plate osteosynthesis of distal radius fractures (157 %) and intramedullary splinting of clavicular fractures (115 %), the anaesthesiologist received a higher radiation exposure than the surgeon. The novel dosimeter system DA provides real-time radiation exposure feedback of the personnel in an orthopaedic and trauma operation theatre for the first time. Data of this study demonstrate that radiation exposure of the personnel depends on the operation type. The first assistant, the theatre nurse and the anaesthesiologist might be exposed to higher radiation doses than the surgeon. DA might help to increase awareness concerning irradiation in an orthopaedic and trauma operation theatre and might enhance staff compliance in using radiation protection techniques. Georg Thieme Verlag KG Stuttgart · New York.

  7. [Surgical treatment of craniocervical instability. Review paper].

    PubMed

    Alpizar-Aguirre, Armando; Lara Cano, Jorge Giovanni; Rosales, Luis; Míramontes, Victor; Reyes-Sánchez, Alejandro Antonio

    2007-01-01

    The concept of spinal instability is still controversial. Anatomical, biomechanical, clinical and radiographic variants are involved and make the definition complicated. There are solid diagnostic bases in cases of fractures and degenerative disorders; however, pure spinal instability is still under study. The latter may be defined as increased mobility that goes beyond the physiological limits of one vertebra over another in at least one of the three spinal planes of motion. In the case of the craniocervical region, its understanding becomes even more challenging, since its anatomy and physiology are more complex and it is more mobile. Surgical treatment is possible with either an anterior or a posterior approach. Best results are obtained with occipitocervical or atlantoaxial stabilization through a posterior approach, since the anterior one has its limitations. For example, a transoral approach with a bone graft provides compression strength but does not enable immediate appropriate fixation and involves the risk of infection. The choice of the surgical approach must consider the patient's medical status, the specific spine levels involved, the extent of neurological compromise, the X-ray abnormalities and the individual pathology. The goals of surgery are achieved through an appropriate anatomical alignment, assuring the protection of the neural elements and achieving proper spine stabilization with as much preservation of the mobile vertebral segments as possible.

  8. Spinal instrumentation for Duchenne's muscular dystrophy: experience of hypotensive anaesthesia to minimise blood loss.

    PubMed

    Fox, H J; Thomas, C H; Thompson, A G

    1997-01-01

    Nineteen patients with Duchenne's muscular dystrophy underwent segmental spinal instrumentation and posterior fusion between 1989 and 1994. The indication for surgery was loss of the ability to walk and development of scoliosis with sitting discomfort. Preoperative assessment included evaluation of pulmonary function. Average age at operation was 12.5 years. Instrumentation and fusion extended from upper thoracic levels to L-5 or the sacrum. A Hartshill rectangle was used in all cases, with banked allograft bone. Severe intraoperative blood loss was avoided by use of hypotensive anaesthesia. Peroperatively, systolic blood pressure was maintained between 75 and 85 mm Hg. Average blood loss was 1,246 ml (range, 400-3,100) or 30% of estimated total blood volume. Average transfusion requirements were 3 units of packed cells. Postoperative analgesia was provided by infusion via an epidural catheter. There were no postoperative wound or chest infections. Three patients required catheterisation for urinary retention. Postoperatively patients were fitted with a Neofract jacket to allow early mobilisation and discharge. Mean postoperative length of stay was 16 days. Posterior spinal fusion by using the Hartshill rectangle provided good correction and fixation. Hypotensive anaesthesia permitted surgery to be performed rapidly in a relatively dry field and avoided the complications of severe intraoperative blood loss and massive transfusion.

  9. Clinical Incidence of Sacroiliac Joint Arthritis and Pain after Sacropelvic Fixation for Spinal Deformity

    PubMed Central

    Sainoh, Takeshi; Takaso, Masashi; Inoue, Gen; Orita, Sumihisa; Eguchi, Yawara; Nakamura, Junichi; Aoki, Yasuchika; Ishikawa, Tetsuhiro; Miyagi, Masayuki; Arai, Gen; Kamoda, Hiroto; Suzuki, Miyako; Kubota, Gou; Sakuma, Yoshihiro; Oikawa, Yasuhiro; Yamazaki, Masashi; Toyone, Tomoaki; Takahashi, Kazuhisa

    2012-01-01

    Purpose Sacroiliac fixation using iliac screws for highly unstable lumbar spine has been reported with an improved fusion rate and clinical results. On the other hand, there is a potential for clinical problems related to iliac fixation, including late sacroiliac joint arthritis and pain. Materials and Methods Twenty patients were evaluated. Degenerative scoliosis was diagnosed in 7 patients, failed back syndrome in 6 patients, destructive spondyloarthropathy in 4 patients, and Charcot spine in 3 patients. All patients underwent posterolateral fusion surgery incorporating lumbar, S1 and iliac screws. We evaluated the pain scores, bone union, and degeneration of sacroiliac joints by X-ray imaging and computed tomography before and 3 years after surgery. For evaluation of low back and buttock pain from sacroiliac joints 3 years after surgery, lidocaine was administered in order to examine pain relief thereafter. Results Pain scores significantly improved after surgery. All patients showed bone union at final follow-up. Degeneration of sacroiliac joints was not seen in the 20 patients 3 years after surgery. Patients showed slight low back and buttock pain 3 years after surgery. However, not all patients showed relief of the low back and buttock pain after injection of lidocaine into the sacroiliac joint, indicating that their pain did not originate from sacroiliac joints. Conclusion The fusion rate and clinical results were excellent. Also, degeneration and pain from sacroiliac joints were not seen within 3 years after surgery. We recommend sacroiliac fixation using iliac screws for highly unstable lumbar spine. PMID:22318832

  10. Positioning and spinal bracing for pain relief in metastatic spinal cord compression in adults.

    PubMed

    Lee, Siew Hwa; Grant, Robin; Kennedy, Catriona; Kilbride, Lynn

    2015-09-24

    This is an updated version of the original Cochrane review published in Issue 3 (Lee 2012) on patient positioning (mobilisation) and bracing for pain relief and spinal stability in adults with metastatic spinal cord compression.Many patients with metastatic spinal cord compression (MSCC) have spinal instability, but their clinician has determined that due to their advanced disease they are unsuitable for surgical internal fixation. Mobilising may be hazardous in the presence of spinal instability as further vertebral collapse can occur. Current guidance on positioning (whether a patient should be managed with bed rest or allowed to mobilise) and whether spinal bracing is helpful, is contradictory. To investigate the correct positioning and examine the effects of spinal bracing to relieve pain or to prevent further vertebral collapse in patients with MSCC. For this update, we searched for relevant studies from February 2012 to 31 March 2015. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE and MEDLINE In Process, EMBASE, AMED, CINAHL, TRIP, SIGN, NICE, UK Clinical Research Network, National Guideline Clearinghouse and PEDro database. We also searched the metaRegister of Controlled Trials (mRCT), ClinicalTrials.gov, UK Clinical Trials Gateway (UKCTG), WHO International Clinical Trials Registry Platform (ICTRP) and Australia New Zealand Clinical Trials Registry (ANZCTR).For the original version, we searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, CINAHL, CANCERLIT, NICE, SIGN, AMED, TRIP, National Guideline Clearinghouse, and PEDro database, in February 2012. We selected randomised controlled trials (RCTs) of adults with MSCC of interventions on positioning (mobilisation) and bracing. Two review authors independently assessed each possible study for inclusion and quality. For the original version of the review, we screened 1611 potentially relevant studies. No studies met the inclusion criteria. Many papers identified the importance of mobilisation, but no RCTs of bed rest versus mobilisation have been undertaken. We identified no RCTs of bracing in MSCC.For this update, we identified 347 potential titles. We screened 300 titles and abstracts after removal of duplicates. We did not identify any additional studies for inclusion. Since publication of the original version of this review, no new studies were found and our conclusions remain unchanged.There is a lack of evidence-based guidance around how to correctly position and when to mobilise patients with MSCC or if spinal bracing is an effective technique for reducing pain or improving quality of life. RCTs are required in this important area.

  11. Spine and Spinal Cord Injuries After Falls From Tree Stands During the Wisconsin Deer Hunting Season.

    PubMed

    Hamilton, Kimberly; Rocque, Brandon; Brooks, Nathaniel

    2017-11-01

    Deer hunting is popular in much of the United States. In Wisconsin, use of tree stands for hunting is common. Spine surgeons at a Level 1 Trauma Center observed a high incidence of spine and spinal cord injury due to falls from tree stands while hunting. This study's purpose is to systematically characterize and classify those injuries. We reviewed the University of Wisconsin Hospital and Clinics' trauma database for tree stand-related injuries from 1999 to 2013. We collected and analyzed data pertaining to hunters' demographics, comorbidities, type and mechanism of injury, injury severity, and management. We identified 117 patients evaluated after a tree stand fall. Sixty-five (ages 16-76) suffered spine fractures that occurred at all levels, from occipital condyle to sacrum, with thoracolumbar compression and burst fractures being most common. Fractures occurred in the following locations: cranio-cervical junction (8.7%), cervical spine (7.6%), cervical-thoracic junction (6.5%), thoracic spine (32.6%), thoracolumbar junction (33.7%), and lumbar spine (10.9%). Twenty-one patients (32%) experienced a single spinal fracture; 44 patients (68%) suffered multiple spinal fractures. Twenty-five patients (38%) required surgical fixation; 19 patients experienced loss of neurologic function: 5 complete spinal cord injuries (SCI), 5 incomplete SCI, 2 central cord syndromes, and 8 radiculopathies. Two mortalities, both of cardiopulmonary etiology, were noted-one in a patient without a spine fracture and the other in a patient with a complete spinal cord injury at T4. The majority of spine fractures are treated nonoperatively. However, enough patients require surgical intervention that consultation with a neurosurgical or orthopedic spine surgeon is prudent. It is more common to have multiple spine fractures from a tree stand fall, therefore, it is recommended that if 1 fracture is identified the entire spine be evaluated for additional fractures. For safety, it is recommended that hunters wear and use safety harnesses appropriately. Additionally, keeping the height of the tree stand at 10 feet or less is associated with a lower likelihood of spinal cord injury. Further study is needed to determine additional interventions such as education that might reduce the injury frequency in this population.

  12. Suture anchor repair of patellar tendon rupture after total knee arthroplasty.

    PubMed

    Kamath, Atul F; Shah, Roshan P; Summers, Nathan; Israelite, Craig L

    2013-12-01

    Extensor mechanism disruption after total knee arthroplasty (TKA) is a complex problem that often requires surgical repair for functional deficits. We present a brief technical note on suture anchor fixation of a patellar tendon rupture after TKA. A surgical technique and literature review follows. Although suture anchor fixation is well described for tendinous repairs in other areas of orthopedic surgery, no study has discussed the use of suture anchors in patellar tendon repair after TKA. The technique must be evaluated in more patients with longer follow-up before adoption. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  13. Closed-loop neuromodulation of spinal sensorimotor circuits controls refined locomotion after complete spinal cord injury.

    PubMed

    Wenger, Nikolaus; Moraud, Eduardo Martin; Raspopovic, Stanisa; Bonizzato, Marco; DiGiovanna, Jack; Musienko, Pavel; Morari, Manfred; Micera, Silvestro; Courtine, Grégoire

    2014-09-24

    Neuromodulation of spinal sensorimotor circuits improves motor control in animal models and humans with spinal cord injury. With common neuromodulation devices, electrical stimulation parameters are tuned manually and remain constant during movement. We developed a mechanistic framework to optimize neuromodulation in real time to achieve high-fidelity control of leg kinematics during locomotion in rats. We first uncovered relationships between neuromodulation parameters and recruitment of distinct sensorimotor circuits, resulting in predictive adjustments of leg kinematics. Second, we established a technological platform with embedded control policies that integrated robust movement feedback and feed-forward control loops in real time. These developments allowed us to conceive a neuroprosthetic system that controlled a broad range of foot trajectories during continuous locomotion in paralyzed rats. Animals with complete spinal cord injury performed more than 1000 successive steps without failure, and were able to climb staircases of various heights and lengths with precision and fluidity. Beyond therapeutic potential, these findings provide a conceptual and technical framework to personalize neuromodulation treatments for other neurological disorders. Copyright © 2014, American Association for the Advancement of Science.

  14. The Role of Fixation and Visual Attention in Object Recognition.

    DTIC Science & Technology

    1995-01-01

    computers", Technical Report, Aritificial Intelligence Lab, M.I. T., AI-Memo-915, June 1986. [29] D.P. Huttenlocher and S.Ullman, "Object Recognition Using...attention", Technical Report, Aritificial Intelligence Lab, M.I. T., AI-memo-770, Jan 1984. [35] E.Krotkov, K. Henriksen and R. Kories, "Stereo...MIT Artificial Intelligence Laboratory [ PCTBTBimON STATEMENT X \\ Afipioved tor puciic reieo*«* \\ »?*•;.., jDi*tiibutK» U»lisut»d* 19951004

  15. Technical considerations to avoid delayed and non-union.

    PubMed

    McMillan, Tristan E; Johnstone, Alan J

    2017-06-01

    For many years intramedullary nails have been a well accepted and successful method of diaphyseal fracture fixation. However, delayed and non unions with this technique do still occur and are associated with significant patient morbidity. The reason for this can be multi-factorial. We discuss a number of technical considerations to maximise fracture reduction, fracture stability and fracture vascularity in order to achieve bony union. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  16. [Dynamic stabilisation and compression without fusion using Dynesys for the treatment of degenerative lumbar spondylolisthesis: a prospective series of 25 cases].

    PubMed

    Ricart, O; Serwier, J-M

    2008-11-01

    We used the Dynesys stabilization to treat degenerative lumber spondylolysis by decompression without fusion with the objective of decreasing the morbidity related to instrumented arthrodesis in older patients yet preventing progression of the displacement. This was a prospective study of 25 patients with symptomatic degenerative lumber spondylolysis associated with degenerative spinal canal stenosis documented by saccoradiculography. For inclusion, static anteroposterior intervertebral displacement had to be at least 3mm in the upright position, irrespective of the displacement on the stress films. The series included 19 women and six men, mean age 71 years (range 53-83). The level was L4-L5 in all 25 cases. Instrumentations involved a single level (L4-L5) or two levels (L3-L5). All patients were explored with computed tomography and saccoradiculography. An MRI was obtained in 12 patients. Pre- and postoperative stress images and views of the entire spinal column in the upright position were used to study pelvic parameters and sagittal spinal balance before and after surgery. Lumbar incidence and lordosis was used to divide the patients into three groups. Outcome was assessed with the Beaujon classification at minimal follow-up of 24 months, mean 34, range 24-72 months. Very good results were obtained in 72% of patients (relative gain greater than 70%) and good results in 28% (relative gain 40-70%). There were not outcomes considered fair or poor. There were two complications: aggravation of preoperative crural paresia with complete recovery and replacement of one neuroaggressive pedicular screw with no consequence thereafter. The stress films confirmed the residual mobility of the instrumented level when the preserved disc was of sufficient height. Postoperative pelvic parameters after Dynesys instrumentation showed improvement in sagittal tilt for T9 by accentuated suprajacent lordosis, even in the event of anterior spinal imbalance preoperatively. Theoretically, solicitation of the pedicular anchors of a rigid instrumentation on a poorly balanced spine would rapidly lead to failure, while fibrous non-union on a globally well balanced spine would be tolerated much longer or even definitively without development of clinical symptoms. In our opinion, the Dynesys instrumentation enables a real restabilization of the spine by adapting to the patients particular spinal balance intra-operatively and postoperatively without imposing a definitive curvature as would a rigid fixation. The ultimate objective is to accompany the aging spine without brutally changing the stress forces. This semi-rigid instrumentation without fusion enables an adapted evolution of the overall spinal degeneration without imposing excessive local forces, which could be sources of stenosis or junctional instability. The most logical indication for this instrumentation is the older subject aged at least 65 years with degenerative lumber spondylolysis and a predominantly self-reducible angular displacement and satisfactory disc height. This context (group 3 in our series) occurs in patients with a weak sacral slope and incidence, as well as minimal lordosis adapted to the pelvic parameters. The Dynesys instrumentation can be a palliative alternative to fusion for more advanced degenerative lumber spondylolysis occurring on spines with anterior imbalance where fusion would be technically difficult in terms of correction of the kyphosis or because of the general risk factors.

  17. Initial stability of cementless acetabular cups: press-fit and screw fixation interaction--an in vitro biomechanical study.

    PubMed

    Tabata, Tomonori; Kaku, Nobuhiro; Hara, Katsutoshi; Tsumura, Hiroshi

    2015-04-01

    Press-fit and screw fixation are important technical factors to achieve initial stability of a cementless acetabular cup for good clinical results of total hip arthroplasty. However, how these factors affect one another in initial cup fixation remains unclear. Therefore, this study aimed to evaluate the mutual influence between press-fit and screw fixation on initial cup stability. Foam bone was subjected to exact hemispherical-shape machining to diameters of 48, 48.5 and 49 mm. A compressive force was applied to ensure seating of a 48-mm-diameter acetabular cup in the foam bone prior to testing. Screws were inserted in six different conditions and tightened in a radial direction at the same torque strength. Then, the socket was rotated with a twist-testing machine, and the torque value at the start of axial rotation between the socket and the foam bone was measured under each screw condition. The torque values for the 48-mm-diameter reaming were >20 N m higher than those for the 48.5- and 49-mm-diameter reaming in each screw condition, indicating that press-fit fixation is stronger than screw fixation. Meanwhile, torque values for the 48.5- and 49-mm-diameter reaming tended to increase with increasing the number of screws. According to our experiment, press-fit fixation of a cementless acetabular cup achieved rigid stability. Although the supplemental screws increased stability of the implant under good press-fit conditions, they showed little impact on whole-cup stability. In the case of insufficient press-fit fixation, cup stability depends on screw stability and increasing the number of additional screws increases cup stability.

  18. Accuracy of image-guided surgical navigation using near infrared (NIR) optical tracking

    NASA Astrophysics Data System (ADS)

    Jakubovic, Raphael; Farooq, Hamza; Alarcon, Joseph; Yang, Victor X. D.

    2015-03-01

    Spinal surgery is particularly challenging for surgeons, requiring a high level of expertise and precision without being able to see beyond the surface of the bone. Accurate insertion of pedicle screws is critical considering perforation of the pedicle can result in profound clinical consequences including spinal cord, nerve root, arterial injury, neurological deficits, chronic pain, and/or failed back syndrome. Various navigation systems have been designed to guide pedicle screw fixation. Computed tomography (CT)-based image guided navigation systems increase the accuracy of screw placement allowing for 3- dimensional visualization of the spinal anatomy. Current localization techniques require extensive preparation and introduce spatial deviations. Use of near infrared (NIR) optical tracking allows for realtime navigation of the surgery by utilizing spectral domain multiplexing of light, greatly enhancing the surgeon's situation awareness in the operating room. While the incidence of pedicle screw perforation and complications have been significantly reduced with the introduction of modern navigational technologies, some error exists. Several parameters have been suggested including fiducial localization and registration error, target registration error, and angular deviation. However, many of these techniques quantify error using the pre-operative CT and an intra-operative screenshot without assessing the true screw trajectory. In this study we quantified in-vivo error by comparing the true screw trajectory to the intra-operative trajectory. Pre- and post- operative CT as well as intra-operative screenshots were obtained for a cohort of patients undergoing spinal surgery. We quantified entry point error and angular deviation in the axial and sagittal planes.

  19. New concept of 3D printed bone clip (polylactic acid/hydroxyapatite/silk composite) for internal fixation of bone fractures.

    PubMed

    Yeon, Yeung Kyu; Park, Hae Sang; Lee, Jung Min; Lee, Ji Seung; Lee, Young Jin; Sultan, Md Tipu; Seo, Ye Bin; Lee, Ok Joo; Kim, Soon Hee; Park, Chan Hum

    Open reduction with internal fixation is commonly used for the treatment of bone fractures. However, postoperative infection associated with internal fixation devices (intramedullary nails, plates, and screws) remains a significant complication, and it is technically difficult to fix multiple fragmented bony fractures using internal fixation devices. In addition, drilling in the bone to install devices can lead to secondary fracture, bone necrosis associated with postoperative infection. In this study, we developed bone clip type internal fixation device using three- dimensional (3D) printing technology. Standard 3D model of the bone clip was generated based on computed tomography (CT) scan of the femur in the rat. Polylacticacid (PLA), hydroxyapatite (HA), and silk were used for bone clip material. The purpose of this study was to characterize 3D printed PLA, PLA/HA, and PLA/HA/Silk composite bone clip and evaluate the feasibility of these bone clips as an internal fixation device. Based on the results, PLA/HA/Silk composite bone clip showed similar mechanical property, and superior biocompatibility compared to other types of the bone clip. PLA/HA/Silk composite bone clip demonstrated excellent alignment of the bony segments across the femur fracture site with well-positioned bone clip in an animal study. Our 3D printed bone clips have several advantages: (1) relatively noninvasive (drilling in the bone is not necessary), (2) patient-specific design (3) mechanically stable device, and (4) it provides high biocompatibility. Therefore, we suggest that our 3D printed PLA/HA/Silk composite bone clip is a possible internal fixation device.

  20. Bi-Pedicle Fixation of Affected Vertebra in Thoracolumbar Burst Fracture.

    PubMed

    Padalkar, Pravin; Mehta, Varshil

    2017-04-01

    Burst fractures of the spine account for 14% of all spinal injuries and more than 50% of all thoracolumbar trauma. However, there is ambiguity while choosing the right treatment plan. Short Segment Pedicle screw Fixation (SSPF) has become an increasingly popular method of treatment of thoracolumbar burst fractures, providing the advantage of incorporating fewer motion segments in the fixation. Various biomechanical studies showed that the use of pedicle screws could achieve stable construct within short-segment fixation. To evaluate the efficacy of SSPF using longest possible screws in both pedicles of fractured vertebra. A retrospective chart review of 25 single burst thoracolumbar fracture patients, operated between May 2009 to 2015 in a tertiary care trauma center, was conducted. Preoperative and post-operative plain radiographs were evaluated for kyphotic angulations using the traditional Cobb method. Anterior Vertebral Height (AVH), Posteriors Vertebral Height (PVH) were measured preoperatively and immediate postoperatively. Average percentage loss of AVH and mid-sagittal height were calculated on preoperative and postoperative X-rays on follow up. Fourteen men and 11 women with an average age of 42.92 years comprised the study population. Mean age at the time of operation was 34.5±14.2 years. Mean operation time was 168±72 (minutes). Average hospitalization time was 9±7 (days). Mean blood loss was 515±485 (ml). There were two cases of postoperative infection and implant failure each. A mean of 15.2° of kyphosis correction was attained from pre-operation to post-operation (p<0.0001). Although, there was a 15° average improvement of kyphosis post-fixation, loss of correction over time was nearly 8°, resulting in a 7° mean correction of kyphosis. A mean loss of AVH on postoperative radiograph was 6.12% and maintained 12.4% at the time of review (p<0.001). Similarly, there was 32.8% mid-sagittal height loss at time of injury, which was improved to only 12.6% as compare to initial height loss (p<0.0001). In this study, we propose SSPF using longest possible screws in both pedicle of fractured vertebra. Bi-pedicular fixation gives significant radiological corrections.

  1. Self-designed posterior atlas polyaxial lateral mass screw-plate fixation for unstable atlas fracture.

    PubMed

    He, Baorong; Yan, Liang; Zhao, Qinpeng; Chang, Zhen; Hao, Dingjun

    2014-12-01

    Most atlas fractures can be effectively treated nonoperatively with external immobilization unless there is an injury to the transverse atlantal ligament. Surgical stabilization is most commonly achieved using a posterior approach with fixation of C1-C2 or C0-C2, but these treatments usually result in loss of the normal motion of the C1-C2 and C0-C1 joints. To clinically validate feasibility, safety, and value of open reduction and fixation using an atlas polyaxial lateral mass screw-plate construct in unstable atlas fractures. Retrospective review of patients who sustained unstable atlas fractures treated with polyaxial lateral mass screw-plate construct. Twenty-two patients with unstable atlas fractures who underwent posterior atlas polyaxial lateral mass screw-plate fixation were analyzed. Visual analog scale, neurologic status, and radiographs for fusion. From January 2011 to September 2012, 22 patients with unstable atlas fractures were treated with this technique. Patients' charts and radiographs were reviewed. Bone fusion, internal fixation placement, and integrity of spinal cord and vertebral arteries were assessed via intraoperative and follow-up imaging. Neurologic function, range of motion, and pain levels were assessed clinically on follow-up. All patients were followed up from 12 to 32 months, with an average of 22.5±18.0 months. A total of 22 plates were placed, and all 44 screws were inserted into the atlas lateral masses. The mean duration of the procedure was 86 minutes, and the average estimated blood loss was 120 mL. Computed tomography scans 9 months after surgery confirmed that fusion was achieved in all cases. There was no screw or plate loosening or breakage in any patient. All patients had well-preserved range of motion. No vascular or neurologic complication was noted, and all patients had a good clinical outcome. An open reduction and posterior internal fixation with atlas polyaxial lateral mass screw-plate is a safe and effective surgical option in the treatment of unstable atlas fractures. This technique can provide immediate reduction and preserve C1-C2 motion. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Biomechanical evaluation of a new fixation device for the thoracic spine.

    PubMed

    Hongo, Michio; Ilharreborde, Brice; Gay, Ralph E; Zhao, Chunfeng; Zhao, Kristin D; Berglund, Lawrence J; Zobitz, Mark; An, Kai-Nan

    2009-08-01

    The technology used in surgery for spinal deformity has progressed rapidly in recent years. Commonly used fixation techniques may include monofilament wires, sublaminar wires and cables, and pedicle screws. Unfortunately, neurological complications can occur with all of these, compromising the patients' health and quality of life. Recently, an alternative fixation technique using a metal clamp and polyester belt was developed to replace hooks and sublaminar wiring in scoliosis surgery. The goal of this study was to compare the pull-out strength of this new construct with sublaminar wiring, laminar hooks and pedicle screws. Forty thoracic vertebrae from five fresh frozen human thoracic spines (T5-12) were divided into five groups (8 per group), such that BMD values, pedicle diameter, and vertebral levels were equally distributed. They were then potted in polymethylmethacrylate and anchored with metal screws and polyethylene bands. One of five fixation methods was applied to the right side of the vertebra in each group: Pedicle screw, sublaminar belt with clamp, figure-8 belt with clamp, sublaminar wire, or laminar hook. Pull-out strength was then assessed using a custom jig in a servohydraulic tester. The mean failure load of the pedicle screw group was significantly larger than that of the figure-8 clamp (P = 0.001), sublaminar belt (0.0172), and sublaminar wire groups (P = 0.04) with no significant difference in pull-out strength between the latter three constructs. The most common mode of failure was the fracture of the pedicle. BMD was significantly correlated with failure load only in the figure-8 clamp and pedicle screw constructs. Only the pedicle screw had a statistically significant higher failure load than the sublaminar clamp. The sublaminar method of applying the belt and clamp device was superior to the figure-8 method. The sublaminar belt and clamp construct compared favorably to the traditional methods of sublaminar wires and laminar hooks, and should be considered as an alternative fixation device in the thoracic spine.

  3. Biomechanical evaluation of a new fixation device for the thoracic spine

    PubMed Central

    Hongo, Michio; Ilharreborde, Brice; Zhao, Chunfeng; Zhao, Kristin D.; Berglund, Lawrence J.; Zobitz, Mark; An, Kai-Nan

    2009-01-01

    The technology used in surgery for spinal deformity has progressed rapidly in recent years. Commonly used fixation techniques may include monofilament wires, sublaminar wires and cables, and pedicle screws. Unfortunately, neurological complications can occur with all of these, compromising the patients’ health and quality of life. Recently, an alternative fixation technique using a metal clamp and polyester belt was developed to replace hooks and sublaminar wiring in scoliosis surgery. The goal of this study was to compare the pull-out strength of this new construct with sublaminar wiring, laminar hooks and pedicle screws. Forty thoracic vertebrae from five fresh frozen human thoracic spines (T5–12) were divided into five groups (8 per group), such that BMD values, pedicle diameter, and vertebral levels were equally distributed. They were then potted in polymethylmethacrylate and anchored with metal screws and polyethylene bands. One of five fixation methods was applied to the right side of the vertebra in each group: Pedicle screw, sublaminar belt with clamp, figure-8 belt with clamp, sublaminar wire, or laminar hook. Pull-out strength was then assessed using a custom jig in a servohydraulic tester. The mean failure load of the pedicle screw group was significantly larger than that of the figure-8 clamp (P = 0.001), sublaminar belt (0.0172), and sublaminar wire groups (P = 0.04) with no significant difference in pull-out strength between the latter three constructs. The most common mode of failure was the fracture of the pedicle. BMD was significantly correlated with failure load only in the figure-8 clamp and pedicle screw constructs. Only the pedicle screw had a statistically significant higher failure load than the sublaminar clamp. The sublaminar method of applying the belt and clamp device was superior to the figure-8 method. The sublaminar belt and clamp construct compared favorably to the traditional methods of sublaminar wires and laminar hooks, and should be considered as an alternative fixation device in the thoracic spine. PMID:19404687

  4. Optimizing pediatric interdental fixation by use of a paramedian palatal fixation site.

    PubMed

    McNichols, Colton H; Hatef, Daniel A; Cole, Patrick D; Hollier, Larry H

    2012-03-01

    Condylar fractures are the most common injury seen in pediatric mandibular trauma. These injuries often cannot be adequately stabilized by conservative techniques such as splinting. The pediatric condyle fracture often requires a period of intermaxillary fixation. Because of the characteristics of the developing dentition, circumdental wiring is often not possible. Surgeons commonly achieve interdental stabilization by the connection of a circum-mandibular wire and a second wire placed through a drill hole in the piriform aperture. This method can be problematic in the young patient whose palatal suture is still patent. In this brief technical note, the use of a paramedian drill hole through the palate posterior to the maxillary incisors is described. It is believed that this method is superior to other techniques because it avoids injury to the deciduous tooth buds and allows for the maxillary wire to be seated in more structurally sound tissues.

  5. Management of irreducible unilateral facet joint dislocations in subaxial cervical spine: two case reports and a review of the literature.

    PubMed

    Zhou, Yu; Zhou, Zhenyu; Liu, Lifeng; Cao, Xuecheng

    2018-03-21

    Skeletal and soft tissue damage are often associated with unilateral facet dislocations, which undoubtedly lead to instability of the spine and further increase difficulties in cervical reduction. This type of irreducible facet dislocation is usually accompanied with potential catastrophic consequences including neurological deficit and severe disability. Therefore, a consistent and evidence-based treatment plan is imperative. The literature regarding the management of traumatic unilateral locked cervical facet dislocations was reviewed. Two patient cases (a 30-year-old Asian man and a 25-year-old Asian woman) who suffered irreducible cervical facet dislocations were presented. These two patients received surgical treatments including posterior reduction by poking facet joints, adjacent spinous process fixation by wire rope banding, anterior plate fixation, and intervertebral fusion after the failure of skull traction and closed reduction. At the postoperative 24-month follow-up, intervertebral fusion was achieved and our patients' neurological status improved based on the American Spinal Injury Association scale, compared with their preoperative status. Unilateral facet joint dislocations of subaxial cervical spine are difficult to reduce when complicated with posterior facet fractures or ligamentous injury. Magnetic resonance imaging can be beneficial for identifying ventral and dorsal compressive lesions, as well as ligamentous or capsule rupture. The combination of posterior reduction and anterior fixation with fusion has advantages in terms of clinical safety, ease of operation, and less iatrogenic damage.

  6. Effects of Lateral Mass Screw Rod Fixation to the Stability of Cervical Spine after Laminectomy

    NASA Astrophysics Data System (ADS)

    Rosli, Ruwaida; Kashani, Jamal; Kadir, Mohammed Rafiq Abdul

    There are many cases of injury in the cervical spine due to degenerative disorder, trauma or instability. This condition may produce pressure on the spinal cord or on the nerve coming from the spine. The aim of this study was, to analyze the stabilization of the cervical spine after undergoing laminectomy via computational simulation. For that purpose, a three-dimensional finite element (FE) model for the multilevel cervical spine segment (C1-C7) was developed using computed tomography (CT) data. There are various decompression techniques that can be applied to overcome the injury. Usually, decompression procedures will create an unstable spine. Therefore, in these situations, the spine is often surgically restabilized by using fusion and instrumentation. In this study, a lateral mass screw-rod fixation was created to stabilize the cervical spine after laminectomy. Material properties of the titanium alloy were assigned on the implants. The requirements moments and boundary conditions were applied on simulated implanted bone. Result showed that the bone without implant has a higher flexion and extension angle in comparison to the bone with implant under applied 1Nm moment. The bone without implant has maximum stress distribution at the vertebrae and ligaments. However, the bone with implant has maximum stress distribution at the screws and rods. Overall, the lateral mass screw-rod fixation provides stability to the cervical spine after undergoing laminectomy.

  7. Severe street and mountain bicycling injuries in adults: a comparison of the incidence, risk factors and injury patterns over 14 years

    PubMed Central

    Roberts, Derek J.; Ouellet, Jean-Francois; Sutherland, Francis R.; Kirkpatrick, Andrew W.; Lall, Rohan N.; Ball, Chad G.

    2013-01-01

    Background Street and mountain bicycling are popular recreational activities and prevalent modes of transportation with the potential for severe injury. The purpose of this investigation was to compare the incidence, risk factors and injury patterns among adults with severe street versus mountain bicycling injuries. Methods We conducted a retrospective cohort study using the Southern Alberta Trauma Database of all adults who were severely injured (injury severity score [ISS] ≥ 12) while street or mountain bicycling between Apr. 1, 1995, and Mar. 31, 2009. Results Among 11 772 severely injured patients, 258 (2.2%) were injured (mean ISS 17, hospital stay 6 d, mortality 7%) while street (n = 209) or mountain bicycling (n = 49). Street cyclists were often injured after being struck by a motor vehicle, whereas mountain bikers were frequently injured after faulty jump attempts, bike tricks and falls (cliffs, roadsides, embankments). Mountain cyclists were admitted more often on weekends than weekdays (61.2% v. 45.0%, p = 0.040). Injury patterns were similar for both cohorts (all p > 0.05), with trauma to the head (67.4%), extremities (38.4%), chest (34.1%), face (26.0%) and abdomen (10.1%) being common. Spinal injuries, however, were more frequent among mountain cyclists (65.3% v. 41.1%, p = 0.003). Surgical intervention was required in 33.3% of patients (9.7% open reduction internal fixation, 7.8% spinal fixation, 7.0% craniotomy, 5.8% facial repair and 2.7% laparotomy). Conclusion With the exception of spine injuries, severely injured cyclists display similar patterns of injury and comparable outcomes, regardless of style (street v. mountain). Helmets and thoracic protection should be advocated for injury prevention. PMID:23706856

  8. [Finite element analysis of stress changes of posterior spinal pedicle screw infixation].

    PubMed

    Yan, Jia-Zhi; Wu, Zhi-Hong; Xu, Ri-Xin; Wang, Xue-Song; Xing, Ze-Jun; Zhao, Yu; Zhang, Jian-Guo; Shen, Jian-Xiong; Wang, Yi-Peng; Qiu, Gui-Xing

    2009-01-06

    To evaluate the mechanical response of L3-L4 segment after posterior interfixation with a transpedicle screw system. Spiral CT machine was used to conduct continuous parallel scan on the L3-L4 section of a 40-year-old healthy male Chinese. The image data thus obtained were introduced into MIMICS software to reconstruct the 2-D data into volume data and obtain 3-D models of every element.. Pro/3-D model construction software system was used to simulate the 3-D entity of L3-L4 fixed by screw robs through spinal pedicle via posterior approach that was introduced into the finite element software ABAQUS to construct a 3-D finite element model. The stress changes on the vertebrae and screw under the axial pressure of 0.5 mPa was analyzed. Under the evenly distributed pressure the displacement of the L4 model was 0.00125815 mm, with an error of only 0.8167% from the datum displacement. The convergence of the model was good. The stress of the fixed vertebral body, intervertebral disc, and internal fixators changed significantly. The stress concentration zone of the intervertebral disc turned from the posterolateral side to anterolateral side. The stress produced by the fixed vertebral bodies decreased significantly. Obvious stress concentration existed in the upper and lower sides of the base of screw and the fixed screw at the upper vertebral body bore greater stress than the lower vertebral body. Integration of computer aided device and finite element analysis can successfully stimulate the internal fixation of L3-IA visa posterior approach and observe the mechanic changes in the vertebral column more directly.

  9. Severe street and mountain bicycling injuries in adults: a comparison of the incidence, risk factors and injury patterns over 14 years.

    PubMed

    Roberts, Derek J; Ouellet, Jean-Francois; Sutherland, Francis R; Kirkpatrick, Andrew W; Lall, Rohan N; Ball, Chad G

    2013-06-01

    Street and mountain bicycling are popular recreational activities and prevalent modes of transportation with the potential for severe injury. The purpose of this investigation was to compare the incidence, risk factors and injury patterns among adults with severe street versus mountain bicycling injuries. We conducted a retrospective cohort study using the Southern Alberta Trauma Database of all adults who were severely injured (injury severity score [ISS] ≥ 12) while street or mountain bicycling between Apr. 1, 1995, and Mar. 31, 2009. Among 11 772 severely injured patients, 258 (2.2%) were injured (mean ISS 17, hospital stay 6 d, mortality 7%) while street (n = 209) or mountain bicycling (n = 49). Street cyclists were often injured after being struck by a motor vehicle, whereas mountain bikers were frequently injured after faulty jump attempts, bike tricks and falls (cliffs, roadsides, embankments). Mountain cyclists were admitted more often on weekends than weekdays (61.2% v. 45.0%, p = 0.040). Injury patterns were similar for both cohorts (all p > 0.05), with trauma to the head (67.4%), extremities (38.4%), chest (34.1%), face (26.0%) and abdomen (10.1%) being common. Spinal injuries, however, were more frequent among mountain cyclists (65.3% v. 41.1%, p = 0.003). Surgical intervention was required in 33.3% of patients (9.7% open reduction internal fixation, 7.8% spinal fixation, 7.0% craniotomy, 5.8% facial repair and 2.7% laparotomy). With the exception of spine injuries, severely injured cyclists display similar patterns of injury and comparable outcomes, regardless of style (street v. mountain). Helmets and thoracic protection should be advocated for injury prevention.

  10. S1 screw bending moment with posterior spinal instrumentation across the lumbosacral junction after unilateral iliac crest harvest.

    PubMed

    Alegre, G M; Gupta, M C; Bay, B K; Smith, T S; Laubach, J E

    2001-09-15

    A biomechanical study comparing fixation across the lumbosacral junction. To determine which long posterior construct across the lumbosacral junction produces the least bending moment on the S1 screw when only one ilium is available for fixation. Recent in vitro studies have demonstrated the benefit of anterior support and fixation into the ilium when instrumenting a long posterior construct across the lumbosacral junction. Four L2-sacrum constructs were tested on six synthetic models of the lumbar spine and pelvis simulating that the right ilium had been harvested. Construct 1: L2-S1 bilateral screws. Construct 2: L2-S1 + left iliac bolt. Construct 3: L2-S1 + left iliac bolt + right S2 screw. Construct 4: L2-S1 + bilateral S2 screws. The four constructs were then retested with an anterior L5-S1 strut. A flexion-extension moment was applied across each construct, and the moment at the left and right S1 pedicle screw was measured with internal strain gauges. Iliac bolt fixation was found to significantly decrease the flexion-extension moment on the ipsilateral S1 screw by 70% and the contralateral screw by 26%. An anterior L5-S1 strut significantly decreased the S1 screw flexion-extension moment by 33%. Anterior support at L5-S1 provided no statistical decrease in the flexion-extension moment when bilateral posterior fixation beyond S1 was present with either a unilateral iliac bolt and contralateral S2 screw, or bilateral S2 screws. There is a significant decrease in the flexion-extension moment on the S1 screw when extending long posterior constructs to either the ilium or S2 sacral screw. There is no biomechanical advantage of the iliac bolt over the S2 screw in decreasing the moment on the S1 screw in flexion and extension. Adding anterior support to long posterior constructs significantly decreases the moment on the S1 screw. Adding distal posterior fixation to either the ilium or S2 decreases the moment on S1 screws more than adding anterior support. Further, adding anterior support when bilateral distal fixation past S1 is already present does not significantly decrease the moment on the S1 screws in flexion and extension.

  11. Biomechanical evaluation of an integrated fixation cage during fatigue loading: a human cadaver study.

    PubMed

    Palepu, Vivek; Peck, Jonathan H; Simon, David D; Helgeson, Melvin D; Nagaraja, Srinidhi

    2017-04-01

    OBJECTIVE Lumbar cages with integrated fixation screws offer a low-profile alternative to a standard cage with anterior supplemental fixation. However, the mechanical stability of integrated fixation cages (IFCs) compared with a cage with anterior plate fixation under fatigue loading has not been investigated. The purpose of this study was to compare the biomechanical stability of a screw-based IFC with a standard cage coupled with that of an anterior plate under fatigue loading. METHODS Eighteen functional spinal units were implanted with either a 4-screw IFC or an anterior plate and cage (AP+C) without integrated fixation. Flexibility testing was conducted in flexion-extension (FE), lateral bending (LB), and axial rotation (AR) on intact spines, immediately after device implantation, and post-fatigue up to 20,000 cycles of FE loading. Stability parameters such as range of motion (ROM) and lax zone (LZ) for each loading mode were compared between the 2 constructs at multiple stages of testing. In addition, construct loosening was quantified by subtracting post-instrumentation ROM from post-fatigue ROM. RESULTS IFC and AP+C configurations exhibited similar stability (ROM and LZ) at every stage of testing in FE (p ≥ 0.33) and LB (p ≥ 0.23) motions. In AR, however, IFCs had decreased ROM compared with AP+C constructs at pre-fatigue (p = 0.07) and at all post-fatigue time points (p ≤ 0.05). LZ followed a trend similar to that of ROM in AR. ROM increased toward intact motion during fatigue cycling for AP+C and IFC implants. IFC specimens remained significantly (p < 0.01) more rigid than specimens in the intact condition during fatigue for each loading mode, whereas AP+C construct motion did not differ significantly (p ≥ 0.37) in FE and LB and was significantly greater (p < 0.01) in AR motion compared with intact specimens after fatigue. Weak to moderate correlations (R 2 ≤ 56%) were observed between T-scores and construct loosening, with lower T-scores leading to decreased stability after fatigue testing. CONCLUSIONS These data indicate that a 4-screw IFC design provides fixation similar to that provided by an AP+C construct in FE and LB during fatigue testing and better stability in AR motion.

  12. Minimally Invasive Implantable Fetal Micropacemaker: Mechanical Testing and Technical Refinements

    PubMed Central

    Zhou, Li; Vest, Adriana N.; Peck, Raymond A.; Sredl, Jonathan P.; Huang, Xuechen; Bar-Cohen, Yaniv; Silka, Michael J.; Pruetz, Jay D.; Chmait, Ramen H.; Loeb, Gerald E.

    2016-01-01

    This paper discusses the technical and safety requirements for cardiac pacing of a human fetus with heart failure and hydrops fetalis secondary to complete heart block. Engineering strategies to meet specific technical requirements were integrated into a systematic design and implementation consisting of a novel fetal micropacemaker, a percutaneous implantation system, and a sterile package that enables device storage and recharging maintenance in a clinical setting. We further analyzed observed problems on myocardial fixation and pacing lead fatigue previously reported in earlier preclinical trials. This paper describes the technical refinements of the implantable fetal micropacemaker to overcome these challenges. The mechanical performance has been extensively tested to verify the improvement of reliability and safety margins of the implantation system. PMID:27021067

  13. Technical Aspects on the Use of Ultrasonic Bone Shaver in Spine Surgery: Experience in 307 Patients

    PubMed Central

    Hazer, Derya Burcu; Yaşar, Barış; Rosberg, Hans-Eric; Akbaş, Aytaç

    2016-01-01

    Aim. We discuss technical points, the safety, and efficacy of ultrasonic bone shaver in various spinal surgeries within our own series. Methods. Between June 2010 and January 2014, 307 patients with various spinal diseases were operated on with the use of an ultrasonic bone curette with microhook shaver (UBShaver). Patients' data were recorded and analyzed retrospectively. The technique for the use of the device is described for each spine surgery procedure. Results. Among the 307 patients, 33 (10.7%) cases had cervical disorder, 17 (5.5%) thoracic disorder, 3 (0.9%) foramen magnum disorder, and 254 (82.7%) lumbar disorders. Various surgical techniques were performed either assisted or alone by UBShaver. The duration of the operations and the need for blood replacement were relatively low. The one-year follow-up with Neck Disability Index (NDI) and Oswestry Disability Index (ODI) scores were improved. We had 5 cases of dural tears (1.6%) in patients with lumbar spinal disease. No neurological deficit was found in any patients. Conclusion. We recommend this device as an assistant tool in various spine surgeries and as a primary tool in foraminotomies. It is a safe device in spine surgery with very low complication rate. PMID:27195299

  14. Single-stage multi-level construct design incorporating ribs and chest wall reconstruction after en bloc resection of spinal tumour.

    PubMed

    Xiao, Jianru; He, Shaohui; Jiao, Jian; Wan, Wei; Xu, Wei; Zhang, Dan; Liu, Weibo; Zhong, Nanzhe; Liu, Tielong; Wei, Haifeng; Yang, Xinghai

    2018-03-01

    Multi-level reconstruction incorporating the chest wall and ribs is technically demanding after multi-segmental total en bloc spondylectomy (TES) of thoracic spinal tumours. Few surgical techniques are reported for effective reconstruction. A novel and straightforward technical reconstruction through posterior-lateral approach was presented to solve the extensive chest wall defect and prevent occurrences of severe respiratory dysfunctions after performing TES. The preliminary outcomes of surgery were reviewed. Multi-level TES was performed for five patients with primary or recurrent thoracic spinal malignancies through posterior-lateral approach. The involved ribs and chest wall were removed to achieve tumour-free margin. Then titanium mesh with allograft bone and pedicle screw-rod system were adopted for the circumferential spinal reconstruction routinely. Titanium rods were modified accordingly to attach to the screw-rod system proximally, and the distal end of rods was dynamically inserted into the ribs. The mean surgery time was 6.7 hours (range 5-8), with the average blood loss of 3260 ml (range 2300-4500). No severe neurological complications were reported while three patients had complaints of slight numbness of chest skin (no. 1, 3, and 5). No severe respiratory complications occurred during peri-operative period. No implant failure and no local recurrence or distant metastases were observed with an average follow-up of 12.5 months. The single-stage reconstructions incorporating spine and chest wall are straightforward and easy to perform. The preliminary outcomes of co-reconstructions are promising and favourable. More studies and longer follow-up are required to validate this technique.

  15. Novel spinal instrumentation to enhance osteogenesis and fusion: a preliminary study.

    PubMed

    MacEwan, Matthew R; Talcott, Michael R; Moran, Daniel W; Leuthardt, Eric C

    2016-09-01

    OBJECTIVE Instrumented spinal fusion continues to exhibit high failure rates in patients undergoing multilevel lumbar fusion or pseudarthrosis revision; with Grade II or higher spondylolisthesis; or in those possessing risk factors such as obesity, tobacco use, or metabolic disorders. Direct current (DC) electrical stimulation of bone growth represents a unique surgical adjunct in vertebral fusion procedures, yet existing spinal fusion stimulators are not optimized to enhance interbody fusion. To develop an advanced method of applying DC electrical stimulation to promote interbody fusion, a novel osteogenic spinal system capable of routing DC through rigid instrumentation and into the vertebral bodies was fabricated. A pilot study was designed to assess the feasibility of osteogenic instrumentation and compare the ability of osteogenic instrumentation to promote successful interbody fusion in vivo to standard spinal instrumentation with autograft. METHODS Instrumented, single-level, posterior lumbar interbody fusion (PLIF) with autologous graft was performed at L4-5 in adult Toggenburg/Alpine goats, using both osteogenic spinal instrumentation (plus electrical stimulation) and standard spinal instrumentation (no electrical stimulation). At terminal time points (3 months, 6 months), animals were killed and lumbar spines were explanted for radiographic analysis using a SOMATOM Dual Source Definition CT Scanner and high-resolution Microcat II CT Scanner. Trabecular continuity, radiodensity within the fusion mass, and regional bone formation were examined to determine successful spinal fusion. RESULTS Quantitative analysis of average bone density in pedicle screw beds confirmed that electroactive pedicle screws used in the osteogenic spinal system focally enhanced bone density in instrumented vertebral bodies. Qualitative and quantitative analysis of high-resolution CT scans of explanted lumbar spines further demonstrated that the osteogenic spinal system induced solid bony fusion across the L4-5 disc space as early as 6 weeks postoperatively. In comparison, inactive spinal instrumentation with autograft was unable to promote successful interbody fusion by 6 months postoperatively. CONCLUSIONS Results of this study demonstrate that novel osteogenic spinal instrumentation supports interbody fusion through the focal delivery of DC electrical stimulation. With further technical development and scientific/clinical validation, osteogenic spinal instrumentation may offer a unique alternative to biological scaffolds and pharmaceutical adjuncts used in spinal fusion procedures.

  16. Endoscopic stent suture fixation for prevention of esophageal stent migration during prolonged dilatation for achalasia treatment.

    PubMed

    Rieder, E; Asari, R; Paireder, M; Lenglinger, J; Schoppmann, S F

    2017-04-01

    The aim of this study is to compare endoscopic stent suture fixation with endoscopic clip attachment or the use of partially covered stents (PCS) regarding their capability to prevent stent migration during prolonged dilatation in achalasia. Large-diameter self-expanding metal stents (30 mm × 80 mm) were placed across the gastroesophageal junction in 11 patients with achalasia. Stent removal was scheduled after 4 to 7 days. To prevent stent dislocation, endoscopic clip attachment, endoscopic stent suture fixation, or PCS were used. The Eckardt score was evaluated before and 6 months after prolonged dilatation. After endoscopic stent suture fixation, no (0/4) sutured stent migrated. When endoscopic clips were used, 80% (4/5) clipped stents migrated (p = 0.02). Of two PCS (n = 2), one migrated and one became embedded leading to difficult stent removal. Technical adverse events were not seen in endoscopic stent suture fixation but were significantly correlated with the use of clips or PCS (r = 0.828, p = 0.02). Overall, 72% of patients were in remission regarding their achalasia symptoms 6 months after prolonged dilatation. Endoscopic suture fixation of esophageal stents but not clip attachment appears to be the best method of preventing early migration of esophageal stents placed at difficult locations such as at the naive gastroesophageal junction. © The Authors 2017. Published by Oxford University Press on behalf of International Society for Diseases of the Esophagus. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  17. Postoperative quality-of-life assessment in patients with spine metastases treated with long-segment pedicle-screw fixation.

    PubMed

    Bernard, Florian; Lemée, Jean-Michel; Lucas, Olivier; Menei, Philippe

    2017-06-01

    OBJECTIVE In recent decades, progress in the medical management of cancer has been significant, resulting in considerable extension of survival for patients with metastatic disease. This has, in turn, led to increased attention to the optimal surgical management of bone lesions, including metastases to the spine. In addition, there has been a shift in focus toward improving quality of life and reducing hospital stay for these patients, and many minimally invasive techniques have been introduced with the aim of reducing the morbidity associated with more traditional open approaches. The goal of this study was to assess the efficacy of long-segment percutaneous pedicle screw stabilization for the treatment of instability associated with thoracolumbar spine metastases in neurologically intact patients. METHODS This study was a retrospective review of data from a prospective database. The authors analyzed cases in which long-segment percutaneous pedicle screw fixation was performed for the palliative treatment of thoracolumbar spinal instability due to spinal metastases in neurologically intact patients. All of the patients included in the study underwent surgery between January 2014 and May 2015 at the authors' institution. Postoperative radiation therapy was planned within 10 days following the stabilization in all cases. Clinical and radiological follow-up assessments were planned for 3 days, 3 weeks, 6 weeks, 3 months, 6 months, and 1 year after surgery. Outcome was assessed by means of standard postoperative evaluation and oncological and spinal quality of life measures (European Organisation for Research and Treatment of Cancer Quality of Life Questionnaire Version 3.0 [EORTC QLQ-C30] and Oswestry Disability Index [ODI], respectively). Moreover, 5 patients were given an activity monitoring device for recording the distance walked daily; preoperative and postoperative daily distances were compared. RESULTS Data from 17 cases were analyzed. There were no complications, and patients showed improvement in pain level and quality of life from the early postoperative period on. The mean ODI score was 62.7 (range 40-84) preoperatively, 35.4 (range 24-59) on postoperative Day 3, and 46.1 (range 30-76) at 3 weeks, 37.6 (range 25-59) at 6 weeks, 34.0 (range 24-59) at 3 months, 39.1 (range 22-64) at 6 months, and 30.0 (range 20-55) at 1 year after screw placement. The mean ODI was significantly improved in the first 45 days (p < 0.001). Improvement was also evident in scores for functional and symptomatic scales of the EORTC QLQ-C30. All patients underwent postoperative radiation therapy within 10 days (mean 7.5). All patients (n = 5) with an activity monitoring device showed improvement in daily walking distance. CONCLUSIONS Less-invasive palliative treatment for advanced spinal metastases is promising as part of a multidisciplinary approach to the care of patients with metastatic disease. The results of this study indicate that percutaneous surgery may allow for rapid improvement in quality of life and walking ability for patients with thoracolumbar instability due to spine metastases. Long-segment percutaneous screw fixation followed by early radiation therapy appears to be a safe and effective treatment option for providing solid and durable stability and improved quality of life for these patients.

  18. The Role of Posterior Screw Fixation in Single-Level Transforaminal Lumbar Interbody Fusion During Whole Body Vibration: A Finite Element Study.

    PubMed

    Fan, Wei; Guo, Li-Xin

    2018-06-01

    Few studies have evaluated the need for supplementary instrumentation after lumbar interbody fusion under the condition of whole body vibration (WBV) that is typically present in vehicles. This study aimed to determine the effect of posterior pedicle screw fixation on dynamic response of the whole lumbar spine to vertical WBV after transforaminal lumbar interbody fusion (TLIF). A previously validated nonlinear, osteoligamentous finite element (FE) model of the intact L1-sacrum human lumbar spine was modified to simulate single-level (L4-L5) TLIF without and with bilateral pedicle screw fixation (BPSF). Transit dynamic analysis was performed on the 2 developed models under a sinusoidal vertical vibration load of ±40 N and a compressive follower preload of 400 N. The resulting dynamic response results for the 2 models in terms of stresses and deformations were recorded and compared. When compared with no fixation, BPSF decreased dynamic responses of the spinal levels to the vertical vibration after TLIF. At the fused level (L4-L5), vibration amplitudes of the von-Mises stresses in L4 inferior endplate and L5 superior endplate decreased after BPSF by 48.0% and 46.4%, respectively. At other disc levels (L1-L2, L2-L3, L3-L4, and L5-S1), vibration amplitudes of the disc bulge, von-Mises stress in annulus ground substance and intradiscal pressure also produced 4.2%-9.0%, 2.3%-8.9%, and 3.4%-8.8% deceases, respectively, after BPSF. After TLIF, application of BPSF can be helpful in the prevention of spine injury during vertical WBV. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Comparison of CD HORIZON SPIRE spinous process plate stabilization and pedicle screw fixation after anterior lumbar interbody fusion. Invited submission from the Joint Section Meeting On Disorders of the Spine and Peripheral Nerves, March 2005.

    PubMed

    Wang, Jeremy C; Haid, Regis W; Miller, Jay S; Robinson, James C

    2006-02-01

    The authors present the early clinical results obtained in patients who underwent SPIRE spinous process plate fixation following anterior lumbar interbody fusion (ALIF). Between May 2003 and January 2005, 32 patients underwent titanium cage and bone morphogenetic protein-augmented ALIF and subsequent SPIRE (21 cases) or bilateral pedicle screw (BPS; 11 cases) fixation. Pedicle screws were implanted using either the open approach (three cases) or using a tubular retractor (eight cases). Patients' charts were reviewed for operative time, estimated blood loss (EBL), hospital length of stay (LOS), and evidence of pseudarthrosis or hardware failure. In SPIRE plate-treated patients, the median EBL (75 ml) was lower than in BPS-treated patients (open BPS [150 ml]; tubular BPS [125 ml]). The median operative time in SPIRE plate-treated patients was also shorter (164 minutes compared with 239 and 250 minutes in the open and tubular BPS, respectively). The median LOS was 3 days for both the SPIRE and tubular BPS groups, but 4 days in the open BPS group. There were no instances of major surgery-induced complication, pseudarthrosis, or hardware failure during mean follow-up periods of 5.5, 7.2, and 4.9 months in the SPIRE, open PS, and tubular BPS groups, respectively. The SPIRE plate is easy to implant and is associated with minimal operative risk. Compared with BPS/rod constructs, SPIRE plate fixation leads to less EBL and shorter operative time, without an increase in the rate of pseudarthrosis. Hospital LOS was also shorter in SPIRE plate-treated patients, which is consistent with the goals of minimal access spinal technologies.

  20. Multimodal intraoperative monitoring: an overview and proposal of methodology based on 1,017 cases

    PubMed Central

    Eggspuehler, Andreas; Muller, Alfred; Dvorak, Jiri

    2007-01-01

    To describe different currently available tests of multimodal intraoperative monitoring (MIOM) used in spine and spinal cord surgery indicating the technical parameters, application and interpretation as an easy understanding systematic overview to help implementation of MIOM and improve communication between neurophysiologists and spine surgeons. This article aims to give an overview and proposal of the different MIOM-techniques as used daily in spine and spinal cord surgery at our institution. Intensive research in neurophysiology over the past decades has lead to a profound understanding of the spinal cord, nerve functions and their intraoperative functional evaluation in anaesthetised patients. At present, spine surgeons and neurophysiologist are faced with 1,883 publications in PubMed on spinal cord monitoring. The value and the limitations of single monitoring methods are well documented. The diagnostic power of the multimodal approach in a larger study population in spine surgery, as measured with sensitivity and specificity, is dealt with elsewhere in this supplement (Sutter et al. in Eur Spine J Suppl, 2007). This paper aims to give a detailed description of the different modalities used in this study. Description of monitoring techniques of the descending and ascending spinal cord and nerve root pathways by motor evoked potentials of the spinal cord and muscles elicited after transcranial electrical motor cortex, spinal cord, cauda equina and nerve root stimulation, continuous EMG, sensory cortical and spinal evoked potentials, as well as direct spinal cord evoked potentials applied on 1,017 patients. The method of MIOM, continuously adapted according to the site, stage of surgery and potential danger to nerve tissues, proved to be applicable with online results, reliable and furthermore teachable. PMID:17653777

  1. Does addition of crosslink to pedicle-screw-based instrumentation impact the development of the spinal canal in children younger than 5 years of age?

    PubMed

    Chen, Zhong-hui; Chen, Xi; Zhu, Ze-zhang; Wang, Bin; Qian, Bang-ping; Zhu, Feng; Sun, Xu; Qiu, Yong

    2015-07-01

    Use of pedicle screws has been popularized in the treatment of pediatric spinal deformity. Despite many studies regarding the effect of pedicle screws on the immature spine, there is no study concerning the impact of addition of crosslink to pedicle-screw-based instrumentation on the development of the spinal canal in young children. This study aims to determine the influence of the screw-rod-crosslink complex on the development of the spinal canal. This study reviewed 34 patients with congenital scoliosis (14 boys and 20 girls) who were treated with posterior-only hemivertebrectomy and pedicle-screw-based short-segment instrumentation before the age of 5 years. The mean age at surgery in this cohort was 37 ± 11 months (range 21-57 months). They were followed up for at least 24 months. Of these patients, 10 underwent only pedicle screw instrumentation without crosslink, and 24 with additional crosslink placement. The vertebrae were divided into three regions as follows: (1) S-CL (screw-crosslink) region, in which the vertebrae were inserted with bilateral pedicle screws and two rods connected with the crosslink; (2) S (screw) region, in which the vertebrae were inserted with bilateral pedicle screws but without crosslink; (3) NS (no screws) region, which comprised vertebrae cephalad or caudal to the instrumented region. The area, anteroposterior and transverse diameters of the spinal canal were measured at all vertebrae on the postoperative and last follow-up computed tomography axial images. The instrumentation-related parameters were also measured, including the distance between the bilateral screws and the screw base angles. The changes in the above measurements were compared between each region to evaluate the instrumentation's effect on the spinal canal growth. The mean follow-up was 37 ± 13 months (range 24-68 months) and the mean age at the last follow-up was 74 ± 20 months (range 46-119 months). In each region, the spinal canal dimensions significantly increased during the follow-up period. There was no significant difference in the spinal canal growth rate between the S and NS regions or between the S-CL and NS regions. Besides, a comparison of the S-CL and S regions regarding the changes in the measurements of the instrumentation construct revealed no significant differences. Pedicle-screw-based instrumentation does not cause retardation of the development of the spinal canal in young children. Moreover, use of the crosslink added to the screw-rod instrumentation also demonstrates no negative effect on the growth of the spinal canal. Thus, the addition of the crosslink to short screw-based instrumentation is recommended as an alternative to increase fixation stability in growing patients, even in very young pediatric population.

  2. Operative techniques of percutaneous endoscopic mini-hemilaminectomy using a uniportal approach in dogs

    PubMed Central

    MOON, Hee-Sup; HWANG, Yong-Hyun; LEE, Hee-Chun; LEE, Jae-Hoon

    2017-01-01

    The present study aimed to investigate the technical feasibility of percutaneous endoscopic mini-hemilaminectomy via a uniportal approach, and to evaluate the possibility of decompression and endoscopic examination of the thoracic and lumbar spinal canals in small dogs during such procedures. Fresh canine cadavers of mixed-breed dogs (n=7) were used in this study. Following injection of a barium and agarose mixture (BA-gel) to stimulate intervertebral disc herniation, percutaneous endoscopic mini-hemilaminectomy was performed using a lateral approach to the thoracic and lumbar vertebrae. BA-gel was removed to decompress the spinal cord using an elevator and rongeurs after mini-hemilaminectomy. Pre and post-operative computed tomography (CT) scans were obtained to evaluate surgical outcomes. Intra-operative complications, incision length, and procedure time were recorded. All procedures were completed with clear visualization of the spinal cord and floor of the spinal canal. The mean total operating time was 58.00 ± 18.06 min. Lengths of incision were under 1 cm in all dogs. Intra-operative complications included iatrogenic nerve root injuries caused by the micro-rongeur in two dogs. CT imaging revealed that removal of BA-gel resulted in sufficient spinal cord decompression. Our findings indicated that percutaneous endoscopic thoracolumbar mini-hemilaminectomy is feasible for spinal cord decompression and allows for adequate observation of the spinal canal. Thus, this technique may be an alternative surgical option for treatment of thoracolumbar disk disease in dogs. PMID:28757523

  3. Resolution of a periodontoid rheumatoid pannus mass in an elderly patient treated with a rigid cervical collar: A case report and literature review.

    PubMed

    Oseni, Abidemi; Kakavas, Georg; Scholz, Martin; Petridis, Athanasios

    2016-06-17

    In patients with C2 rheumatoid pannus with spinal cord compression the treatment of choice is extensive surgery either through a transoral resection of the dens axis or a dorsal stabilisation, or both. We present a case of an 11-mm rheumatoid pannus with significant compression of the spinal cord, which failed surgical treatment with respect to dorsal stabilisation. Therefore, rigid cervical collar for 8 weeks followed by soft collar for another 4 weeks was chosen as a treatment option. During the follow-up period of 1 year, the pannus reduced significantly and the spinal cord decompressed. In cases where surgery is not an option or is technically very demanding, the alternative of cervical collar immobilisation is a satisfying option.

  4. The posterior transpedicular approach for circumferential decompression and instrumented stabilization with titanium cage vertebrectomy reconstruction for spinal tumors: consecutive case series of 50 patients.

    PubMed

    Metcalfe, Stephen; Gbejuade, Herbert; Patel, Nitin R

    2012-07-15

    A retrospective case series. To demonstrate the feasibility, safety, and results of the posterior transpedicular approach for circumferential decompression and instrumented reconstruction of thoracolumbar spinal tumors. Patients presenting with spinal tumor disease requiring 3-column instrumented stabilization are typically treated with a combined anterior and posterior surgical approach. However, circumferential decompression and instrumented stabilization may also be achieved through a single-stage, midline posterior transpedicular approach. Fifty consecutive patients (27 women and 23 men) underwent surgery between 2003 and 2010 at a single institution by the senior author. Mean age was 55.9 years (range, 25-79 yr).Single or multilevel, contiguous subtotal vertebrectomy was performed ranging from T1 to L4 (38 thoracic and 12 lumbar). Three-column spinal stabilization was achieved using posterior pedicle screw fixation and vertebral body reconstruction, with a titanium cage introduced through the posterior transpedicular route. The mean follow-up period was 17 months (range, 1-54 mo). The mean operating time was 4.2 hours. The mean estimated blood loss for a subgroup of 9 patients with hypervascular tumor pathology was 3933 mL (range, 2700-5800 mL). The mean blood loss in the remaining 41 patients was 1262 mL (range, 250-2500 mL).Postoperative neurological status was maintained or improved in all patients. Mean postoperative stay was 7.7 days (range, 3-12 d). At last review, 14 patients were alive, with a mean survival of 36 months (range, 13-71 mo). The mean survival for the 36 patients who died was 19 months (range, 2 weeks to 54 mo). This is the largest reported series of patients with spinal tumor disease undergoing circumferential decompression and 3-column instrumented stabilization through the posterior transpedicular approach.This surgical approach provides sufficient access for safe and effective circumferential decompression and stabilization, with reduced complications compared with costotransversectomy or combined anterior transcavitary and posterior approaches.

  5. Recurrent Neurological Deterioration after Conservative Treatment for Acute Traumatic Central Cord Syndrome without Bony Injury: Seventeen Operative Case Reports.

    PubMed

    Jin, Wenjie; Sun, Xin; Shen, Kangping; Wang, Jia; Liu, Xingzhen; Shang, Xiushuai; Tao, Hairong; Zhu, Tong

    2017-11-01

    The mechanisms of late recurrent neurological deterioration after conservative treatment for acute traumatic central cord syndrome (ATCCS) remain unclear. Seventeen operative cases sustaining late recurrent neurological deterioration after conservative treatment for ATCCS were reviewed to investigate the mechanisms. The assessment of neurological status was based on International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI). Gender, age, cause of injury, results of image, conservative treatment and operative data, and neurological status at different time points were recorded. The mean age of 17 patients was 43.8 ± 2.3 years old, and the causes of the cervical injury were 14 vehicle accidents and 3 falls. The neurological deficits of 17 patients on admission were not serious, and patients recovered quickly after conservative treatment. No fractures or dislocation were found in any patient's radiographs or CT scan images. All 17 patients performed first MRI test in 4 days and there was a slight or mild compression on the spinal cord in 16 patients. Eight patients had a second MRI scan ∼6 weeks later, which showed that there was aggravated compression on the spinal cord in six patients. All patients underwent an anterior approach to cervical decompression and internal fixation operation. During the operation, there were loose discs found in all 17 patients, obvious ruptures of disks found in 3 patients, obvious ruptures of anterior longitudinal ligaments (ALLs) found in 8 patients, and obvious ruptures of posterior longitudinal ligaments (PLLs) found in 7 patients. There was serious adhesion between PLLs and cervical disks in 12 patients. In five patients, partial ossification of PLLs was detected. All patients had a good neurological outcome at 6 month follow-up. Ruptures of ALLs, PLLs, and discs resulting in cervical instability and secondary compression on the spinal cord were important causes for recurrent neurological deterioration after conservative treatment for ATCCS. With timely spinal decompression after recurrent neurological deterioration, patients could achieve a good neurological outcome.

  6. Long-term outcomes of vertebral column resection for kyphosis in patients with cured spinal tuberculosis: average 8-year follow-up.

    PubMed

    Liu, Congcong; Lin, Li; Wang, Weixing; Lv, Guohua; Deng, Youwen

    2016-05-01

    OBJECTIVE The authors conducted a study to evaluate the long-term clinical and radiographic outcomes of vertebral column resection (VCR) for kyphosis in patients with cured spinal tuberculosis. METHODS This was a retrospective study. Between 2003 and 2009, 28 consecutive patients with cured spinal tuberculosis underwent VCR for kyphosis in which the target vertebra was removed completely. Autologous iliac crest bone graft or titanium mesh packed with autograft was placed into the osteotomy gap to reconstruct the spine for anterior column stability. Posterior pedicle screw fixation and fusion were typically performed. Radiographic parameters, including kyphosis angle and sagittal balance, were measured, and visual analog scale score, America Spinal Injury Association grade, Scoliosis Research Society outcome instrument (SRS-22) score, Oswestry Disability Index, patient satisfaction index, and long-term complications were evaluated. RESULTS This study included 12 males and 16 females, with an average age of 20.9 years at the time of surgery. The average follow-up was 96.9 months. No deaths occurred in this study. At the final follow-up, the kyphosis angle improved from the preoperative average of 70.7° to the final follow-up average of 30.2°, and the average kyphosis correction loss was 8.5°. The sagittal balance averaged 15.4 mm before surgery, 2.8 mm after surgery, and 5.4 mm at the final followup. Thirteen patients showed improvement of more than 1 America Spinal Injury Association grade. The visual analog scale, Oswestry Disability Index, and SRS-22 scores improved significantly, and the overall satisfaction rate was 92.9%. Adjacent-segment degeneration occurred in 3 patients. No severe instrumentation-related complications were observed. CONCLUSIONS The long-term safety and efficacy of the VCR technique for treating spinal tuberculosis-related kyphosis were favorable, and no severe late-stage complications appeared. Lumbar tubercular kyphosis showed a tendency for sagittal decompensation within the first 3 postoperative years. Cases of adjacent-segment degenerations were relatively few and mild without clinical symptoms.

  7. The history of head transplantation: a review.

    PubMed

    Lamba, Nayan; Holsgrove, Daniel; Broekman, Marike L

    2016-12-01

    Since the turn of the last century, the prospect of head transplantation has captured the imagination of scientists and the general public. Recently, head transplant has regained attention in popular media, as neurosurgeons have proposed performing this procedure in 2017. Given the potential impact of such a procedure, we were interested in learning the history of the technical hurdles that need to be overcome, and determine if it is even technically possible to perform such a procedure on humans today. We conducted a historical review of available literature on the technical challenges and developments of head transplantation. The many social, psychological, ethical, religious, cultural, and legal questions of head transplantation were beyond the scope of this review. Our historical review identified the following important technical considerations related to performing a head transplant: maintenance of blood flow to an isolated brain via vessel anastomosis; availability of immunosuppressive agents; spinal anastomosis and fusion following cord transfection; pain control in the recipient. Several animal studies have demonstrated success in maintaining recipient cerebral perfusion and achieving immunosuppression. However, there is currently sparse evidence in favor of successful spinal anastomosis and fusion after transection. While recent publications by an Italian group offer novel approaches to this challenge, research on this topic has been sparse and hinges on procedures performed in animal models in the 1970s. How transferrable these older methods are to the human nervous system is unclear and warrants further exploration. Our review identified several important considerations related to performing a viable head transplantation. Besides the technical challenges that remain, there are important ethical issues to consider, such as exploitation of vulnerable patients and informed consent. Thus, besides the remaining technical challenges, these ethical issues will also need to be addressed before moving these studies to the clinic.

  8. [Airway management in a man with ankylosing spondylitis].

    PubMed

    Gil, S; Jamart, V; Borrás, R; Miranda, A

    2007-02-01

    We report a case of difficult airway management in a 41-year-old man with ankylosing spondylitis who was scheduled for total left hip replacement surgery. After several failed attempts to achieve regional anesthesia, we converted to general anesthesia with orotracheal intubation using a fiberoptic bronchoscope. Ankylosing spondylitis leads to fibrosis, ossification, and ankylosis along the spinal column and sacroiliac articulations. Cervical column and atlantooccipital articulation mobility are reduced and in severe cases the cervical vertebrae become fixed in a flexed position. This portion of the spine is also the most susceptible to fracture, particularly in hyperextension, an event that could lead to damage to the cervical spinal cord during maneuvers to manage the airway. Patients with this condition may also have temporomandibular joint involvement, further complicating airway management. We report the case of a patient with ankylosing spondylitis with fixation along the entire spine. The airway was managed by intubation with a fiberoptic bronchoscope. Spontaneous ventilation was maintained during the maneuver, and sedation was achieved with perfusion of remifentanil as the only anesthetic agent following failure of intradural anesthesia.

  9. [Mechanical testing of implant properties of thoracoscopic implantation of ventral spinal stabilizing systems. Comparative study with the ISO/DIS 12189-2 corpectomy model and an improved synthetic model].

    PubMed

    Grupp, T M; Beisse, R; Potulski, M; Marnay, T; Beger, J; Blömer, W

    2002-04-01

    A new modular anterior fixation system MACS TL (modular anterior construct system for the thoracic and lumbar spine) has been developed for use in thoracoscopic spondylodesis. This system demonstrates high angular stability and meets the surgical requirements for an endoscopic approach. The objective of the current study was fatigue testing of the MACS TL implant system using a corpectomy model according to ISO/DIS 12189-2 and a synthetic model recently developed by Kotani et al. [6]. The MACS TL system demonstrated good mechanical properties with a high stiffness compared to the published data reviewed. The importance of dynamic testing in a corpectomy model has been demonstrated by comparing the MACS TL plate system with an early prototype, which has not yet been clinically evaluated. The corpectomy model according to Kotani et al. offers an interesting alternative to the ISO/DIS 12189-2 test method for asymmetrically designed and antero-laterally positioned spinal implants due to the unconstrained ball joint.

  10. Vertebral body spread in thoracolumbar burst fractures can predict posterior construct failure.

    PubMed

    De Iure, Federico; Lofrese, Giorgio; De Bonis, Pasquale; Cultrera, Francesco; Cappuccio, Michele; Battisti, Sofia

    2018-06-01

    The load sharing classification (LSC) laid foundations for a scoring system able to indicate which thoracolumbar fractures, after short-segment posterior-only fixations, would need longer instrumentations or additional anterior supports. We analyzed surgically treated thoracolumbar fractures, quantifying the vertebral body's fragment displacement with the aim of identifying a new parameter that could predict the posterior-only construct failure. This is a retrospective cohort study from a single institution. One hundred twenty-one consecutive patients were surgically treated for thoracolumbar burst fractures. Grade of kyphosis correction (GKC) expressed radiological outcome; Oswestry Disability Index and visual analog scale were considered. One hundred twenty-one consecutive patients who underwent posterior fixation for unstable thoracolumbar burst fractures were retrospectively evaluated clinically and radiologically. Supplementary anterior fixations were performed in 34 cases with posterior instrumentation failure, determined on clinic-radiological evidence or symptomatic loss of kyphosis correction. Segmental kyphosis angle and GKC were calculated according to the Cobb method. The displacement of fracture fragments was obtained from the mean of the adjacent end plate areas subtracted from the area enclosed by the maximum contour of vertebral fragmentation. The "spread" was derived from the ratio between this subtraction and the mean of the adjacent end plate areas. Analysis of variance, Mann-Whitney, and receiver operating characteristic were performed for statistical analysis. The authors report no conflict of interest concerning the materials or methods used in the present study or the findings specified in this paper. No funds or grants have been received for the present study. The spread revealed to be a helpful quantitative measurement of vertebral body fragment displacement, easily reproducible with the current computed tomography (CT) imaging technologies. There were no failures of posterior fixations with preoperative spreads <42% and losses of correction (LOC)<10°, whereas spreads >62.7% required supplementary anterior supports whenever LOC>10° were recorded. Most of the patients in a "gray zone," with spreads between 42% and 62.7%, needed additional anterior supports because of clinical-radiological evidence of impending mechanical failures, which developed independently from the GKC. Preoperative kyphosis (p<.001), load sharing score (p=.002), and spread (p<.001) significantly affected the final surgical treatment (posterior or circumferential). Twenty-two years after the LSC, both improvements in spinal stabilization systems and software imaging innovations have modified surgical concepts and approach on spinal trauma care. Spread was found to be an additional tool that could help in predicting the posterior construct failure, providing an objective preoperative indicator, easily reproducible with the modern viewers for CT images. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Treatment of Extreme Tuberculous Kyphosis Using Spinal Osteotomy and Halo-Pelvic Traction: A Case Report.

    PubMed

    Yu, Bin; Zhu, Ke; Zhao, Deng; Wang, Fei; Liang, Yijian

    2016-02-01

    A case report of treatment of extreme tuberculous kyphosis using spinal osteotomy and halopelvic traction. The aim of this study was to describe the process and outcome of treatment of a case with extreme tuberculous kyphosis using spine osteotomy and halo-pelvic traction. Spinal tuberculosis causes destruction, deformity, and paraplegia. Long-standing kyphosis may progress with growth in children, and produces respiratory insufficiency, and neurologic deficit. Surgery may help to prevent or reverse the neurological deterioration, while improving pulmonary function in cases with significant spinal deformity. Review of records and radiographs. A 24-year-old female with tuberculous angular kyphosis presented with bilateral lower extremities paresis and dyspnea. The vertebral bodies from T3 to T9 were severely destructed, with a Cobb's angle of 180°on radiographs. The total duration of distraction using halopelvic apparatus kept 10 months. During the duration of traction, the patient underwent a posterior release surgery because flexibility of the kyphosis was not sufficient. Pedicle subtraction osteotomy and pedicle screw fixation were performed to achieve final correction when the Cobb's angle decreased to about 80°. After the whole treatment of halopelvic traction and spine ostetomy, the patient's height increased nearly 30 cm, whereas the angular kyphosis was corrected to a Cobb's angle of 30°. The patient had no complication and neurological deterioration during the treatment. Correction angle and good sagittal balance were well maintained in the duration of 2 years' follow-up. The halo-pelvic apparatus produces high corrective forces applied over a long period, and it provides a slow and safe correction of deformity. In cases of extreme kyphotic deformity, halopelvic traction is an appropriate technique, while avoiding many serious complications from a rapid, one-stage correction. N/A.

  12. Delayed grafting of fetal CNS tissue into chronic compression lesions of the adult cat spinal cord.

    PubMed

    Anderson, D K; Reier, P J; Wirth Iii, E D; Theele, D P; Mareci, T; Brown, S A

    1991-01-01

    This review summarizes a series of experiments involving transplants of embryonic feline CNS tissue into chronic compression lesions of the adult cat spinal cord. Fetal spinal cord (FSC), caudal brainstem (BSt), neocortex (NCx) or a combination of either FSC/NCx or FSC/BSt was transplanted as solid pieces or as a suspension of dissociated cells into the developed cystic cavities produced by static-load compression trauma 2-10 weeks prior to grafting. All cats were immunosuppressed with cyclosporin A and their locomotor function was assessed for 6-30 weeks. Following the period of evaluation, all recipients were perfused with fixative and tissue specimens, taken at the transplantation site, were processed for general histological and/or immunocytochemical analysis. Viable graft tissue was found in all animals with the exception of two cats which showed active rejection of their transplants. All of the viable intraspinal grafts were extensively vascularized and did not show any signs of imminent or on-going tissue rejection. Fetal cat CNS grafts showed an extended maturational phase in that features of immature neural tissue (e.g. a paucity of myelination) were still seen even 6-9 weeks after transplantation. By 20-30 weeks, FSC and BSt grafts had attained a more advanced stage of maturation. Transplants in these chronic lesions were extensively blended with both the gray and white matter of the host spinal cord and could be visualized by magnetic resonance imaging (MRI). MRI could also detect regions of cavitation at the graft-host interface, as well as within some transplants. While preliminary evidence from behavioral studies suggest that the FSC and BSt grafts may improve or spare locomotor function in some recipients, a more rigorous analysis of post-grafting locomotor function is required to determine conclusively the functionality of these transplants.

  13. Technical tip: tightrope fixation of neer type II distal clavicle fracture supported by a case series.

    PubMed

    Haque, Syed; Khan, Anwar; Sharma, A; Sundararajan, Sabapathy

    2014-03-27

    We present a case series of 3 patients who underwent a novel technique of tight rope fixation for Neer type II distal clavicle fracture. 2-3 cm incision was made lateral to the fracture site moving inferomedially. Part of the distal end of clavicle was exposed close to fracture site and further dissection was carried out to reveal the coracoid process. Tight rope fixation of the distal ends of clavicle and coracoid was performed to achieve satisfactory fracture reduction on x-ray. 4 weeks of sling with gentle pendulum movement were followed by active shoulder movement exercises. Radiographic union was reached at 6 weeks' time, while the patients achieved proper shoulder functionality 3 months following the operation. Neer type II distal clavicle fractures are characterized by disruption of the coracoclavicular ligament with wide proximal fragment displacement. Overall, type II distal clavicle fractures have a 20-30% nonunion rate if treated non-surgically. Various techniques have been described for the treatment of these fractures, including hook plate and nailing. Tight rope fixation provides proper apposition of the fracture fragments for union by maintaining a reduced coracoclavicular interval.

  14. Review of fixation techniques for the four-part fractured proximal humerus in hemiarthroplasty.

    PubMed

    Baumgartner, Daniel; Nolan, Betsy M; Mathys, Robert; Lorenzetti, Silvio Rene; Stüssi, Edgar

    2011-07-18

    The clinical outcome of hemiarthroplasty for proximal humeral fractures is not satisfactory. Secondary fragment dislocation may prevent bone integration; the primary stability by a fixation technique is therefore needed to accomplish tuberosity healing. Present technical comparison of surgical fixation techniques reveals the state-of-the-art approach and highlights promising techniques for enhanced stability. A classification of available fixation techniques for three- and four part fractures was done. The placement of sutures and cables was described on the basis of anatomical landmarks such as the rotator cuff tendon insertions, the bicipital groove and the surgical neck. Groups with similar properties were categorized. Materials used for fragment fixation include heavy braided sutures and/or metallic cables, which are passed through drilling holes in the bone fragments. The classification resulted in four distinct groups: A: both tuberosities and shaft are fixed together by one suture, B: single tuberosities are independently connected to the shaft and among each other, C: metallic cables are used in addition to the sutures and D: the fragments are connected by short stitches, close to the fragment borderlines. A plurality of techniques for the reconstruction of a fractured proximal humerus is found. The categorisation into similar strategies provides a broad overview of present techniques and supports a further development of optimized techniques. Prospective studies are necessary to correlate the technique with the clinical outcome.

  15. Review of fixation techniques for the four-part fractured proximal humerus in hemiarthroplasty

    PubMed Central

    2011-01-01

    Introduction The clinical outcome of hemiarthroplasty for proximal humeral fractures is not satisfactory. Secondary fragment dislocation may prevent bone integration; the primary stability by a fixation technique is therefore needed to accomplish tuberosity healing. Present technical comparison of surgical fixation techniques reveals the state-of-the-art approach and highlights promising techniques for enhanced stability. Method A classification of available fixation techniques for three- and four part fractures was done. The placement of sutures and cables was described on the basis of anatomical landmarks such as the rotator cuff tendon insertions, the bicipital groove and the surgical neck. Groups with similar properties were categorized. Results Materials used for fragment fixation include heavy braided sutures and/or metallic cables, which are passed through drilling holes in the bone fragments. The classification resulted in four distinct groups: A: both tuberosities and shaft are fixed together by one suture, B: single tuberosities are independently connected to the shaft and among each other, C: metallic cables are used in addition to the sutures and D: the fragments are connected by short stitches, close to the fragment borderlines. Conclusions A plurality of techniques for the reconstruction of a fractured proximal humerus is found. The categorisation into similar strategies provides a broad overview of present techniques and supports a further development of optimized techniques. Prospective studies are necessary to correlate the technique with the clinical outcome. PMID:21762540

  16. Technical evaluation of the Aerospace Medical Panel Specialists Meeting on Escape Problems and Manoeuvres in Combat Aircraft

    NASA Technical Reports Server (NTRS)

    Jones, W. L.

    1974-01-01

    A technical evaluation of the papers presented at a conference on escape systems for helicopters and V/STOL aircraft was made. The subjects discussed include the following: (1) bioengineering aspects of spinal injury during ejection, (2) aerodynamic forces acting on crewman during escape, (3) operational practicality of fly away ejection seats, (4) helicopter survivability requirements, (5) ejection experience from V/STOL aircraft, and (6) research projects involving escape and retrieval systems.

  17. Optimal Post-Operative Immobilisation for Supracondylar Humeral Fractures.

    PubMed

    Azzolin, Lucas; Angelliaume, Audrey; Harper, Luke; Lalioui, Abdelfettah; Delgove, Anaïs; Lefèvre, Yan

    2018-05-25

    Supracondylar humeral fractures (SCHFs) are very common in paediatric patients. In France, percutaneous fixation with two lateral-entry pins is widely used after successful closed reduction. Post-operative immobilisation is typically with a long arm cast combined with a tubular-bandage sling that immobilises the shoulder and holds the arm in adduction and internal rotation to prevent external rotation of the shoulder, which might cause secondary displacement. The objective of this study was to compare this standard immobilisation technique to a posterior plaster splint with a simple sling. Secondary displacement is not more common with a posterior plaster splint and sling than with a long arm cast. 100 patients with extension Gartland type III SCHFs managed by closed reduction and percutaneous fixation with two lateral-entry pins between December 2011 and December 2015 were assessed retrospectively. Post-operative immobilisation was with a posterior plaster splint and a simple sling worn for 4 weeks. Radiographs were obtained on days 1, 45, and 90. Secondary displacement occurred in 8% of patients. No patient required revision surgery. The secondary displacement rate was comparable to earlier reports. Of the 8 secondary displacements, 5 were ascribable to technical errors. The remaining 3 were not caused by rotation of the arm and would probably not have been prevented by using the tubular-bandage sling. A posterior plaster splint combined with a simple sling is a simple and effective immobilisation method for SCHFs provided internal fixation is technically optimal. IV, retrospective observational study. Copyright © 2018. Published by Elsevier Masson SAS.

  18. Accuracy of pedicle screw insertion by AIRO® intraoperative CT in complex spinal deformity assessed by a new classification based on technical complexity of screw insertion.

    PubMed

    Rajasekaran, S; Bhushan, Manindra; Aiyer, Siddharth; Kanna, Rishi; Shetty, Ajoy Prasad

    2018-01-09

    To develop a classification based on the technical complexity encountered during pedicle screw insertion and to evaluate the performance of AIRO ® CT navigation system based on this classification, in the clinical scenario of complex spinal deformity. 31 complex spinal deformity correction surgeries were prospectively analyzed for performance of AIRO ® mobile CT-based navigation system. Pedicles were classified according to complexity of insertion into five types. Analysis was performed to estimate the accuracy of screw placement and time for screw insertion. Breach greater than 2 mm was considered for analysis. 452 pedicle screws were inserted (T1-T6: 116; T7-T12: 171; L1-S1: 165). The average Cobb angle was 68.3° (range 60°-104°). We had 242 grade 2 pedicles, 133 grade 3, and 77 grade 4, and 44 pedicles were unfit for pedicle screw insertion. We noted 27 pedicle screw breach (medial: 10; lateral: 16; anterior: 1). Among lateral breach (n = 16), ten screws were planned for in-out-in pedicle screw insertion. Among lateral breach (n = 16), ten screws were planned for in-out-in pedicle screw insertion. Average screw insertion time was 1.76 ± 0.89 min. After accounting for planned breach, the effective breach rate was 3.8% resulting in 96.2% accuracy for pedicle screw placement. This classification helps compare the accuracy of screw insertion in range of conditions by considering the complexity of screw insertion. Considering the clinical scenario of complex pedicle anatomy in spinal deformity AIRO ® navigation showed an excellent accuracy rate of 96.2%.

  19. [Surgical treatment of symptomatic cervical vertebral hemangioma associated with cervical spondylotic myelopathy].

    PubMed

    Liu, Fajing; Shen, Yong; Ding, Wenyuan; Yang, Dalong; Xu, Jiaxin

    2011-01-01

    To investigate the treatment methods and the clinical therapeutic effects of symptomatic cervical vertebral hemangioma associated with cervical spondylotic myelopathy. A retrospective analysis was performed in 18 patients (10 males and 8 females, aged 30-62 years with an average age of 45.3 years) with cervical vertebral hemangioma associated with cervical spondylotic myelopathy between January 2006 and September 2008. The disease duration was 10-26 months (mean, 15.6 months). All patients had single vertebral hemangioma, including 2 cases at C3, 3 cases at C4, 5 cases at C5, 5 cases at C6, and 3 cases at C7. The X-ray films showed a typical "palisade" change. According to the clinical and imaging features, there were 13 cases of type II and 5 cases of type IV of cervical hemangioma. The standard anterior cervical decompression and fusion with internal fixation were performed and then percutaneous vertebroplasty (PVP) was used. The cervical X-ray films were taken to observe bone cement distribution and the internal fixation after operation. The recovery of neurological function and the neck pain relief were measured by Japanese Orthopaedic Association (JOA) score and visual analogue scale (VAS) score. All operations were successful with no spinal cord and nerves injury, and the incisions healed well. Anterior bone cement leakage occurred in 2 cases without any symptoms. All cases were followed up 24-28 months (mean, 26 months) and the symptoms were improved at different degrees without fracture and collapse of vertebra or recurrence of hemangioma. During the follow-up, there was no implant loosening, breakage and displacement, and the mean fusion time was 4 months (range, 3-4.5 months). The JOA score and VAS score had a significant recovery at 3 months and at last follow-up when compared with preoperative values (P < 0.05). Based on JOA score at last follow-up, the results were excellent in 9 cases, good in 6 cases, fair in 2 cases, and poor in 1 case. The anterior cervical decompression and fusion with internal fixation combined with PVP treatment is one of the ideal ways to treat symptomatic cervical vertebral hemangioma associated with cervical spondylotic myelopathy, which could completely decompress the spinal cord and effectively alleviate the clinical symptoms caused by vertebral hemangioma.

  20. Early or delayed stabilization in severely injured patients with spinal fractures? Current surgical objectivity according to the Trauma Registry of DGU: treatment of spine injuries in polytrauma patients.

    PubMed

    Bliemel, Christopher; Lefering, Rolf; Buecking, Benjamin; Frink, Michael; Struewer, Johannes; Krueger, Antonio; Ruchholtz, Steffen; Frangen, Thomas Manfred

    2014-02-01

    Because of a lack of evidence, the appropriate timing of surgical stabilization of thoracic and lumbar spine injuries in severely injured patients is still controversial. Data of a large international trauma register were analyzed to investigate the medical care situation of unstable spinal column fractures in patients with multiple injuries, so as to examine the outcome related to timing of surgical stabilization. Data sets of the Trauma Registry of German Trauma Society (Deutsche Gesellschaft für Unfallchirurgie [DGU]) (1993-2010) were analyzed. The Trauma Registry of DGU is a prospective, multicenter register that provides information on severely injured patients. All patients with an Injury Severity Score (ISS) of 16 or greater caused by blunt trauma, subsequent treatment of 7 days or more, 16 years or older, and thoracic or lumbar spine injuries (spine Abbreviated Injury Scale [AIS] score ≥ 2) were included in our analysis. Patients with relevant spine injuries classified as having a spine AIS score of 3 or greater were further analyzed in terms of whether they got early (<72 hours) or late (>72 hours) surgical treatment due to unstable spinal column fractures. Of 24,974 patients, 8,994 (36.0%) had documented spinal injuries (spine AIS score ≥ 2). A total of 1,309 patients who sustained relevant thoracic spine injuries (spine AIS score ≥ 3) and 994 patients who experienced lumbar spine trauma and classified as having spine AIS score of 3 or greater were more precisely analyzed. Of these, 68.2% and 71.0%, respectively, received an early thoracic or lumbar spine fixation. With an increase in spinal injury severity, an increase in early stabilization in the thoracic and lumbar spine was seen. In the group of patients with early surgical stabilization, significantly shorter hospital stays, shorter intensive care unit stays, fewer days on mechanical ventilation, and lower rates of sepsis were seen. In the case that additional body regions were affected, for example, when patients were critically ill, a delayed spinal stabilization was more often performed. A spinal stabilization at an early stage (<72 hours) is presumed to be beneficial. Although some patients may require delay due to necessary medical improvement, every reasonable effort should be made to treat patients with instable spinal column fractures as soon as possible. If an early surgical treatment is feasible, severely injured patients may benefit from a shorter period of hospital treatment and a lower rate of complications. Therapeutic study, level III.

  1. Pectoralis Major Repair With Unicortical Button Fixation And Suture Tape.

    PubMed

    Sanchez, Anthony; Ferrari, Marcio B; Frangiamore, Salvatore J; Sanchez, George; Kruckeberg, Bradley M; Provencher, Matthew T

    2017-06-01

    Although injuries of the pectoralis major muscle are generally uncommon, ruptures of the pectoralis major are occasionally seen in younger, more active patients who participate in weightlifting activities. These injuries usually occur during maximal contraction of the muscle, while in extension and external rotation. In the case of a rupture, operative treatment is advocated especially in young, active patients regardless of the chronicity of the injury. Various surgical techniques for reattachment of the avulsed tendon have been described, but bone tunnel and suture anchor repair techniques are most widely used. In this Technical Note, we present our preferred technique for acute pectoralis major rupture repair involving use of cortical buttons for tendon stump-to-bone fixation.

  2. Anterior transarticular C1-C2 fixation with contralateral screw insertion: a report of two cases and technical note.

    PubMed

    Lvov, Ivan; Grin, Andrey; Kaykov, Aleksandr; Smirnov, Vladimir; Krylov, Vladimir

    2017-08-08

    Anterior transarticular fixation of the C1-C2 vertebrae is a well-known technique that involves screw insertion through the body of the C2 vertebra into the lateral masses of the atlas through an anterior transcervical approach. Meanwhile, contralateral screw insertion has been previously described only in anatomical studies. We describe two case reports of the clinical application of this new technique. In Case 1, the patient was diagnosed with an unstable C1 fracture. The clinical features of the case did not allow for any type of posterior atlantoaxial fusion, Halo immobilization, or routine anterior fixation using the Reindl and Koller techniques. The possible manner of screw insertion into the anterior third of the right lateral mass was via a contralateral trajectory, which was performed in this case. Case 2 involved a patient with neglected posteriorly dislocated dens fracture who could not lie in the prone position due to concomitant cardiac pathology. Reduction of atlantoaxial dislocation was insufficient, even after scar tissue resection at the fracture, while transdental fusion was not possible. Considering the success of the previous case, atlantoaxial fixation was performed through the small approach, using the Reindl technique and contralateral screw insertion. These two cases demonstrate the potential of anterior transarticular fixation of C1-C2 vertebrae in cases where posterior atlantoaxial fusion is not achievable. This type of fixation can be performed through a single approach if one screw is inserted using the Reindl technique and another is inserted via a contralateral trajectory.

  3. MRI and MRA of spinal cord arteriovenous shunts.

    PubMed

    Condette-Auliac, Stéphanie; Boulin, Anne; Roccatagliata, Luca; Coskun, Oguzhan; Guieu, Stéphanie; Guedin, Pierre; Rodesch, Georges

    2014-12-01

    The purpose of this review is to describe the diagnostic criteria for spinal cord arteriovenous shunts (SCAVSs) when using magnetic resonance imaging (MRI) and magnetic resonance angiography (MRA), and to discuss the extent to which the different MRI and MRA sequences and technical parameters provide the information that is required to diagnose these lesions properly. SCAVSs are divided into four groups according to location (paraspinal, epidural, dural, or intradural) and type (fistula or nidus); each type of lesion is described. SCAVSs are responsible for neurological symptoms due to spinal cord or nerve root involvement. MRI is usually the first examination performed when a spinal cord lesion is suspected. Recognition of the image characteristics of vascular lesions is mandatory if useful sequences are to be performed-especially MRA sequences. Because the treatment of SCAVSs relies mainly on endovascular therapies, MRI and MRA help with the planning of the angiographic procedure. We explain the choice of MRA sequences and parameters, the advantages and pitfalls to be aware of in order to obtain the best visualization, and the analysis of each lesion. © 2014 Wiley Periodicals, Inc.

  4. Pedicle screw fixation for isthmic spondylolisthesis: does posterior lumbar interbody fusion improve outcome over posterolateral fusion?

    PubMed

    La Rosa, Giovanni; Conti, Alfredo; Cacciola, Fabio; Cardali, Salvatore; La Torre, Domenico; Gambadauro, Nicola Maria; Tomasello, Francesco

    2003-09-01

    Posterolateral fusion involving instrumentation-assisted segmental fixation represents a valid procedure in the treatment of lumbar instability. In cases of anterior column failure, such as in isthmic spondylolisthesis, supplemental posterior lumbar interbody fusion (PLIF) may improve the fusion rate and endurance of the construct. Posterior lumbar interbody fusion is, however, a more demanding procedure and increases costs and risks of the intervention. The advantages of this technique must, therefore, be weighed against those of a simple posterior lumbar fusion. Thirty-five consecutive patients underwent pedicle screw fixation for isthmic spondylolisthesis. In 18 patients posterior lumbar fusion was performed, and in 17 patients PLIF was added. Clinical, economic, functional, and radiographic data were assessed to determine differences in clinical and functional results and biomechanical properties. At 2-year follow-up examination, the correction of subluxation, disc height, and foraminal area were maintained in the group in which a PLIF procedure was performed, but not in the posterolateral fusion-only group (p < 0.05). Nevertheless, no statistical intergroup differences were demonstrated in terms of neurological improvement (p = 1), economic (p = 0.43), or functional (p = 0.95) outcome, nor in terms of fusion rate (p = 0.49). The authors' findings support the view that an interbody fusion confers superior mechanical strength to the spinal construct; when posterolateral fusion is the sole intervention, progressive loss of the extreme correction can be expected. Such mechanical insufficiency, however, did not influence clinical outcome.

  5. [Use of pedicle percutaneous cemented screws in the management of patients with poor bone stock].

    PubMed

    Pesenti, S; Graillon, T; Mansouri, N; Adetchessi, T; Tropiano, P; Blondel, B; Fuentes, S

    2016-12-01

    Management of patients with poor bone stock remains difficult due to the risks of mechanical complications such as screws pullouts. At the same time, development of minimal invasive spinal techniques using a percutaneous approach is greatly adapted to these fragile patients with a reduction in operative time and complications. The aim of this study was to report our experience with cemented percutaneous screws in the management of patients with a poor bone stock. Thirty-five patients were included in this retrospective study. In each case, a percutaneous osteosynthesis using cemented screws was performed. Indications were osteoporotic fractures, metastasis or fractures on ankylosing spine. Depending on radiologic findings, short or long constructs (2 levels above and below) were performed and an anterior column support (kyphoplasty or anterior approach) was added. Evaluation of patients was based on pre and postoperative CT-scans associated with clinical follow-up with a minimum of 6 months. Eleven men and 24 women with a mean age of 73 years [60-87] were included in the study. Surgical indication was related to an osteoporotic fracture in 20 cases, a metastasis in 13 cases and a fracture on ankylosing spine in the last 2 cases. Most of the fractures were located between T10 and L2 and a long construct was performed in 22 cases. Percutaneous kyphoplasty was added in 24 cases and a complementary anterior approach in 3 cases. Average operative time was 86minutes [61-110] and blood loss was estimated as minor in all the cases. In the entire series, average volume of cement injected was 1.8 cc/screw. One patient underwent a major complication with a vascular leakage responsible for a cement pulmonary embolism. With a 9 months average follow-up [6-20], no cases of infection or mechanical complication was reported. Minimal invasive spinal techniques are greatly adapted to the management of fragile patients. The use of percutaneous cemented screws is, in our experience, a valuable alternative for spinal fixation in patients with poor bone stock. This technique allows a good bony fixation with a low rate of complications. However, rigorous preoperative planning is necessary in order to avoid complications. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  6. Unilateral lag screw fixation of isolated non-union atlas lateral mass fracture: a new technical note.

    PubMed

    Farrokhi, Majid Reza; Kiani, Arash; Rezaei, Hamid

    2018-01-15

    We describe a novel and new technique of posterior unilateral lag screw fixation of non-union atlas lateral mass fracture. A 46-year-old man presented with cervical pain and tenderness after a vehicle turn over accident and he was diagnosed to have left atlas lateral mass fracture. He was initially treated by immobilization using Minerva orthosis. About 2 months later, he developed severe neck pain and limitation of motion and thus he was scheduled for operation due to non-union atlas lateral mass fracture. A 28 mm lag screw was inserted under anterior-posterior and lateral fluoroscopic views. The entrance point was at the dorsal aspect of left atlas posterior arc at its junction to the lateral mass, and by using the trajectory of 10 degrees medial and 22 degrees cephalad fracture reduction was achieved. Unilateral lag screw fixation of atlas fractures is an appropriate, safe and effective surgical technique for the management of unilateral atlas fractures.

  7. Combined spinal epidural anesthesia for laparoscopic appendectomy in adults: A case series

    PubMed Central

    Mane, Rajesh S.; Patil, Manjunath C.; Kedareshvara, K. S.; Sanikop, C. S.

    2012-01-01

    Background: Laparoscopy is one of the most common surgical procedures and is the procedure of choice for most of the elective abdominal surgeries performed preferably under endotracheal general anesthesia. Technical advances in the field of laparoscopy have helped to reduce surgical trauma and discomfort, reduce anesthetic requirement resulting in shortened hospital stay. Recently, regional anaesthetic techniques have been found beneficial, especially in patients at a high risk to receive general anesthesia. Herewith we present a case series of laparoscopic appendectomy in eight American Society of Anaesthesiologists (ASA) I and II patients performed under spinal-epidural anaesthesia. Methods: Eight ASA Grade I and II adult patients undergoing elective Laparoscopic appendectomy received Combined Spinal Epidural Anaesthesia. Spinal Anaesthesia was performed at L2-L3 interspace using 2 ml of 0.5% (10 mg) hyperbaric Bupivacaine mixed with 0.5ml (25 micrograms) of Fentanyl. Epidural catheter was inserted at T10-T11 interspace for inadequate spinal anaesthesia and postoperative pain relief. Perioperative events and operative difficulty were studied. Systemic drugs were administered if patients complained of shoulder pain, abdominal discomfort, nausea or hypotension. Results: Spinal anaesthesia was adequate for surgery with no operative difficulty in all the patients. Intraoperatively, two patients experienced right shoulder pain and received Fentanyl, one patient was given Midazolam for anxiety and two were given Ephedrine for hypotension. The postoperative period was uneventful. Conclusion: Spinal anaesthesia with Hyperbaric Bupivacaine and Fentanyl is adequate and safe for elective laparoscopic appendectomy in healthy patients but careful evaluation of the method is needed particularly in compromised cardio respiratory conditions. PMID:22412773

  8. Spinal cord stimulation for axial low back pain: a prospective, controlled trial comparing dual with single percutaneous electrodes.

    PubMed

    North, Richard B; Kidd, David H; Olin, John; Sieracki, Jeffrey M; Farrokhi, Farrokh; Petrucci, Loredana; Cutchis, Protagoras N

    2005-06-15

    A prospective, controlled, clinical trial comparing single and dual percutaneous electrodes in the treatment of axial low back pain from failed back surgery syndrome. To clarify technical requirements and test the hypothesis that placing two linear arrays in parallel, thereby doubling the number of contacts, improves outcome. Technical improvements have enhanced outcomes of spinal cord stimulation for chronic axial low back pain. Dual, parallel electrodes reportedly improve these outcomes. Acting as their own controls, 20 patients who passed screening with single, 4-contact electrodes received permanent dual, 4-contact electrodes with 7- or 10-mm intercontact distances at the same vertebral level(s). We quantified and compared the technical and clinical results of the single and dual electrodes, adjusting stimulation parameters to specific psychophysical thresholds. Single electrodes provided significant (P < 0.01) advantages in patient- and computer-calculated ratings of pain coverage by paresthesias and in the scaled amplitude necessary to cover the low back, compared with dual 7-mm electrodes. Slight advantages without statistical significance were observed for the single over the dual 10-mm electrodes. Amplitude requirements were significantly lower for the single electrode than for either dual electrode. At long-term follow-up, 53% of patients met the criteria for clinical success. While we observed disadvantages for dual electrodes in treating axial low back pain, we achieved technical success with single or dual electrodes in most patients and maintained this success clinically with dual electrodes in 53%.

  9. [Surgical treatment of degenerative lumbar scoliosis with multi-segment lumbar spinal stenosis].

    PubMed

    Lan, Jiaping; Tang, Xun; Xu, Yongqing; Zhou, Tianhua; Shi, Jian; Cui, Yi; Xiang, Qili; Cai, Zhijun; Zhao, Qingkai; Yang, Xiaoyong; Zhao, Caihua

    2014-08-01

    To explore the surgical indications, decompression and fusion method, and fusion level selection of degenerative lumbar scoliosis (DLS) and multi-segment lumbar spinal stenosis. Between April 2000 and November 2011, 46 cases of DLS and multi-segment lumbar spinal stenosis were treated with multi-level decompression by fenestration and crept enlargement plus internal fixation by interbody and posterior-lateral bone graft fusion (5 segments or above). Of 46 cases, 25 were male and 21 were female, with a mean age of 70.2 years (range, 65-81 years) and with a mean disease duration of 6.4 years (range, 4 years and 6 months to 13 years). X-ray films showed that the lumbar Cobb angle was (26.7 ± 10.0) degrees, and the lumbar lordotic angle was (20.3 ± 8.8)degrees. The lumbar CT and MRI images showed three-segment stenosis in 24 cases, four-segment stenosis in 17 cases, and five-segment stenosis in 5 cases. A total of 165 stenosed segments included 12 L1,2, 34 L2,3, 43 L3,4, 45 L4,5, and 31 L5 and S1. Visual analogue scale (VAS) score, Oswestry disability index (ODI), and Japanese Orthopedic Association (JOA) score (29 points) were employed to evaluate effectiveness. Thirteen patients had leakage of cerebrospinal fluid during operation, and no infection was found after corresponding treatment; pulmonary infection and urinary system infection occurred in 4 and 2 patients respectively, who relieved after received antibiotic therapy; 8 patients with poor wound healing received dressing change, adequate drainage, debridement and suture. No death, paralysis, central nervous system infection, or other complication was observed in these patients. Forty-six cases were followed up 12-72 months (mean, 36.2 months). Lumbago and backache and intermittent claudication of lower extremity were obviously improved. During follow-up, no screw incising, loosening and broken screws, or pseudarthrosis was noted under X-ray film and CT scanning. At last follow-up, the lumbar Cobb angle was reduced to (9.8 ± 3.6) degrees, while the lumbar lordotic angle was increased to (34.1 ± 9.4) degrees, which were significantly improved when compared with preoperative ones (t = 16.935, P = 0.000; t = 15.233, P = 0.000). At last follow-up, VAS, ODI, and JOA scores were 3.2 ± 1.2, 35.5% ± 14.0%, and 26.6 ± 5.7 respectively, showing significant differences when compared with preoperative scores (8.0 ± 2.2, 60.8% ± 13.3%, and 12.9 ± 3.4) (t = 19.857, P = 0.000; t = 16.642, P = 0.000; t = 15.922, P = 0.000). Multi-segment decompression by fenestration and crept enlargement plus internal fixation by interbody and posterior-lateral bone graft fusion is helpful to relieve nerve compression symptoms, rebuild spinal balance, and improve the life quality of the patients. It is a very effective way to treat DLS and multi-segment lumbar spinal stenosis.

  10. Cellular bone matrices: viable stem cell-containing bone graft substitutes

    PubMed Central

    Skovrlj, Branko; Guzman, Javier Z.; Al Maaieh, Motasem; Cho, Samuel K.; Iatridis, James C.; Qureshi, Sheeraz A.

    2015-01-01

    BACKGROUND CONTEXT Advances in the field of stem cell technology have stimulated the development and increased use of allogenic bone grafts containing live mesenchymal stem cells (MSCs), also known as cellular bone matrices (CBMs). It is estimated that CBMs comprise greater than 17% of all bone grafts and bone graft substitutes used. PURPOSE To critically evaluate CBMs, specifically their technical specifications, existing published data supporting their use, US Food and Drug Administration (FDA) regulation, cost, potential pitfalls, and other aspects pertaining to their use. STUDY DESIGN Areview of literature. METHODS A series of Ovid, Medline, and Pubmed-National Library of Medicine/National Institutes of Health (www.ncbi.nlm.nih.gov) searches were performed. Only articles in English journals or published with English language translations were included. Level of evidence of the selected articles was assessed. Specific technical information on each CBM was obtained by direct communication from the companies marketing the individual products. RESULTS Five different CBMs are currently available for use in spinal fusion surgery. There is a wide variation between the products with regard to the average donor age at harvest, total cellular concentration, percentage of MSCs, shelf life, and cell viability after defrosting. Three retrospective studies evaluating CBMs and fusion have shown fusion rates ranging from 90.2% to 92.3%, and multiple industry-sponsored trials are underway. No independent studies evaluating spinal fusion rates with the use of CBMs exist. All the commercially available CBMs claim to meet the FDA criteria under Section 361, 21 CFR Part 1271, and are not undergoing FDA premarket review. The CBMs claim to provide viable MSCs and are offered at a premium cost. Numerous challenges exist in regard to MSCs’ survival, function, osteoblastic potential, and cytokine production once implanted into the intended host. CONCLUSIONS Cellular bone matrices may be a promising bone augmentation technology in spinal fusion surgery. Although CBMs appear to be safe for use as bone graft substitutes, their efficacy in spinal fusion surgery remains highly inconclusive. Large, nonindustry sponsored studies evaluating the efficacy of CBMs are required. Without results from such studies, surgeons must be made aware of the potential pitfalls of CBMs in spinal fusion surgery. With the currently available data, there is insufficient evidence to support the use of CBMs as bone graft substitutes in spinal fusion surgery. PMID:24929059

  11. Cellular bone matrices: viable stem cell-containing bone graft substitutes.

    PubMed

    Skovrlj, Branko; Guzman, Javier Z; Al Maaieh, Motasem; Cho, Samuel K; Iatridis, James C; Qureshi, Sheeraz A

    2014-11-01

    Advances in the field of stem cell technology have stimulated the development and increased use of allogenic bone grafts containing live mesenchymal stem cells (MSCs), also known as cellular bone matrices (CBMs). It is estimated that CBMs comprise greater than 17% of all bone grafts and bone graft substitutes used. To critically evaluate CBMs, specifically their technical specifications, existing published data supporting their use, US Food and Drug Administration (FDA) regulation, cost, potential pitfalls, and other aspects pertaining to their use. Areview of literature. A series of Ovid, Medline, and Pubmed-National Library of Medicine/National Institutes of Health (www.ncbi.nlm.nih.gov) searches were performed. Only articles in English journals or published with English language translations were included. Level of evidence of the selected articles was assessed. Specific technical information on each CBM was obtained by direct communication from the companies marketing the individual products. Five different CBMs are currently available for use in spinal fusion surgery. There is a wide variation between the products with regard to the average donor age at harvest, total cellular concentration, percentage of MSCs, shelf life, and cell viability after defrosting. Three retrospective studies evaluating CBMs and fusion have shown fusion rates ranging from 90.2% to 92.3%, and multiple industry-sponsored trials are underway. No independent studies evaluating spinal fusion rates with the use of CBMs exist. All the commercially available CBMs claim to meet the FDA criteria under Section 361, 21 CFR Part 1271, and are not undergoing FDA premarket review. The CBMs claim to provide viable MSCs and are offered at a premium cost. Numerous challenges exist in regard to MSCs' survival, function, osteoblastic potential, and cytokine production once implanted into the intended host. Cellular bone matrices may be a promising bone augmentation technology in spinal fusion surgery. Although CBMs appear to be safe for use as bone graft substitutes, their efficacy in spinal fusion surgery remains highly inconclusive. Large, nonindustry sponsored studies evaluating the efficacy of CBMs are required. Without results from such studies, surgeons must be made aware of the potential pitfalls of CBMs in spinal fusion surgery. With the currently available data, there is insufficient evidence to support the use of CBMs as bone graft substitutes in spinal fusion surgery. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Percutaneous spinal fixation simulation with virtual reality and haptics.

    PubMed

    Luciano, Cristian J; Banerjee, P Pat; Sorenson, Jeffery M; Foley, Kevin T; Ansari, Sameer A; Rizzi, Silvio; Germanwala, Anand V; Kranzler, Leonard; Chittiboina, Prashant; Roitberg, Ben Z

    2013-01-01

    In this study, we evaluated the use of a part-task simulator with 3-dimensional and haptic feedback as a training tool for percutaneous spinal needle placement. To evaluate the learning effectiveness in terms of entry point/target point accuracy of percutaneous spinal needle placement on a high-performance augmented-reality and haptic technology workstation with the ability to control the duration of computer-simulated fluoroscopic exposure, thereby simulating an actual situation. Sixty-three fellows and residents performed needle placement on the simulator. A virtual needle was percutaneously inserted into a virtual patient's thoracic spine derived from an actual patient computed tomography data set. Ten of 126 needle placement attempts by 63 participants ended in failure for a failure rate of 7.93%. From all 126 needle insertions, the average error (15.69 vs 13.91), average fluoroscopy exposure (4.6 vs 3.92), and average individual performance score (32.39 vs 30.71) improved from the first to the second attempt. Performance accuracy yielded P = .04 from a 2-sample t test in which the rejected null hypothesis assumes no improvement in performance accuracy from the first to second attempt in the test session. The experiments showed evidence (P = .04) of performance accuracy improvement from the first to the second percutaneous needle placement attempt. This result, combined with previous learning retention and/or face validity results of using the simulator for open thoracic pedicle screw placement and ventriculostomy catheter placement, supports the efficacy of augmented reality and haptics simulation as a learning tool.

  13. Mechanical properties and cytocompatibility of oxygen-modified β-type Ti-Cr alloys for spinal fixation devices.

    PubMed

    Liu, Huihong; Niinomi, Mitsuo; Nakai, Masaaki; Cho, Ken; Narita, Kengo; Şen, Mustafa; Shiku, Hitoshi; Matsue, Tomokazu

    2015-01-01

    In this study, various amounts of oxygen were added to Ti-10Cr (mass%) alloys. It is expected that a large changeable Young's modulus, caused by a deformation-induced ω-phase transformation, can be achieved in Ti-10Cr-O alloys by the appropriate oxygen addition. This "changeable Young's modulus" property can satisfy the otherwise conflicting requirements for use in spinal implant rods: high and low moduli are preferred by surgeons and patients, respectively. The influence of oxygen on the microstructures and mechanical properties of the alloys was examined, as well as the bending springback and cytocompatibility of the optimized alloy. Among the Ti-10Cr-O alloys, Ti-10Cr-0.2O (mass%) alloy shows the largest changeable Young's modulus following cold rolling for a constant reduction ratio. This is the result of two competing factors: increased apparent β-lattice stability and decreased amounts of athermal ω phase, both of which are caused by oxygen addition. The most favorable balance of these factors for the deformation-induced ω-phase transformation occurred at an oxygen concentration of 0.2mass%. Ti-10Cr-0.2O alloy not only exhibits high tensile strength and acceptable elongation, but also possesses a good combination of high bending strength, acceptable bending springback and great cytocompatibility. Therefore, Ti-10Cr-0.2O alloy is a potential material for use in spinal fixture devices. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  14. Spinal cord injuries among paragliders in Norway.

    PubMed

    Rekand, T; Schaanning, E E; Varga, V; Schattel, U; Gronning, M

    2008-06-01

    A national retrospective descriptive study. To study the clinical effects of spinal cord injuries (SCIs) caused by paragliding accidents in Norway. Spinal cord units at Haukeland University Hospital, Sunnaas Rehabilitation Hospital and St Olav Hospital in Norway. We studied the medical files for nine patients with SCI caused by paragliding accidents to evaluate the circumstances of the accidents, and clinical effects of injury. We obtained the data from hospital patient files at all three spinal units in Norway and crosschecked them through the Norwegian Paragliding Association's voluntary registry for injuries. All patients were hospitalized from 1997 to 2006, eight men and one woman, with mean age 30.7 years. The causes of the accidents were landing problems combined with unexpected wind whirls, technical problems and limited experience with unexpected events. All patients contracted fractures in the thoracolumbal junction of the spine, most commonly at the L1 level. At clinical follow-up, all patients presented clinically incomplete SCI (American Spinal Injury Association impairment scores B-D). Their main health problems differed widely, ranging from urinary and sexual disturbances to neuropathic pain and loss of motor functioning. Only three patients returned to full-time employment after rehabilitation. Paragliding accidents cause spinal fractures predominantly in the thoracolumbal junction with subsequent SCIs and increased morbidity. All patients experienced permanent health problems that influenced daily activities and required long-time clinical follow-up and medical intervention. Better education in landing techniques and understanding of aerodynamics may reduce the risk of paragliding accidents.

  15. Gaskell revisited: new insights into spinal autonomics necessitate a revised motor neuron nomenclature.

    PubMed

    Fritzsch, Bernd; Elliott, Karen L; Glover, Joel C

    2017-11-01

    Several concepts developed in the nineteenth century have formed the basis of much of our neuroanatomical teaching today. Not all of these were based on solid evidence nor have withstood the test of time. Recent evidence on the evolution and development of the autonomic nervous system, combined with molecular insights into the development and diversification of motor neurons, challenges some of the ideas held for over 100 years about the organization of autonomic motor outflow. This review provides an overview of the original ideas and quality of supporting data and contrasts this with a more accurate and in depth insight provided by studies using modern techniques. Several lines of data demonstrate that branchial motor neurons are a distinct motor neuron population within the vertebrate brainstem, from which parasympathetic visceral motor neurons of the brainstem evolved. The lack of an autonomic nervous system in jawless vertebrates implies that spinal visceral motor neurons evolved out of spinal somatic motor neurons. Consistent with the evolutionary origin of brainstem parasympathetic motor neurons out of branchial motor neurons and spinal sympathetic motor neurons out of spinal motor neurons is the recent revision of the organization of the autonomic nervous system into a cranial parasympathetic and a spinal sympathetic division (e.g., there is no sacral parasympathetic division). We propose a new nomenclature that takes all of these new insights into account and avoids the conceptual misunderstandings and incorrect interpretation of limited and technically inferior data inherent in the old nomenclature.

  16. Functional and radiological evaluations of high-energy tibial plateau fractures treated with double-buttress plate fixation.

    PubMed

    Yu, Z; Zheng, L; Zhang, Y; Li, J; Ma, Bao'an

    2009-05-14

    This study was designed to evaluate the functional and radiological outcomes of patients with complex tibial plateau fractures treated with double-buttress plate fixation. Sixty five cases of complex (Schatzker type V and VI) tibial plateau fractures were treated with double-buttress plate fixation in our centre from September 2001 to September 2006 through two separate plate incisions. Fifty four patients were followed up for a period ranging from 12 to 48 months and evaluated for the functional and radiological outcomes by a series of standard questionnaire and measurement. Due to the good exposure without any extensive soft-tissue dissection of the double-buttress plate fixation, the fractures in all 54 patients were healed and the treatment achieved greater than 90% of satisfactory-to-excellent rates of reduction. The mean time of bone union was 15.4 weeks (range, 12-30 weeks), and the mean time of full weight-bearing was 18.7 weeks (range, 14-26 weeks). At the final follow-up visit, no patients showed knee instability; the mean range of motion was 107.6 degrees (range, 85 degrees -130 degrees ). For all patients, no statistically significant difference in the functional outcomes was observed between their 6-months and final follow-up visits; or in the radiological findings between their immediate postoperative and final follow-up examinations. Double-buttress plate fixation is a feasible treatment option for bilcondylar and complex tibial plateau fractures. Although technically demanding, it offers reliable stability without additional postoperative adjuvant external fixation, and at the same time avoids extensive soft tissue dissection, allowing the early painless range of motion.

  17. Systematic review of cortical bone trajectory versus pedicle screw techniques for lumbosacral spine fusion.

    PubMed

    Phan, Kevin; Ramachandran, Vignesh; Tran, Tommy M; Shah, Kevin P; Fadhil, Matthew; Lackey, Alan; Chang, Nicholas; Wu, Ai-Min; Mobbs, Ralph J

    2017-12-01

    Fusion of the lumbosacral spine is a common surgical procedure to address a range of spinal pathologies. Fixation in lumbar fusion has traditionally been performed using pedicle screw (PS) augmentation. However, an alternative method of screw insertion via cortical bone trajectory (CBT) has been advocated as a less invasive approach which improves initial fixation and reduces neurovascular injury. There is a paucity of robust clinical evidence to support these claims, particularly in comparison to traditional pedicle screws. This study aims to review the available evidence to assess the merits of the CBT approach. Six electronic databases were searched for original published studies which compared CBT with traditional PS and their findings reviewed. Nine comparative studies were identified through a comprehensive literature search. Studies were classified as retrospective cohort, prospective cohort or case control studies with medium quality as assessed by the GRADE criteria. The available literature is not cohesive regarding outcomes and complications of CBT versus PT procedures. Most studies found no difference in operative time, but reported less blood loss during CBT. Radiological outcomes show no difference in slippage at one year although CBT is associated with greater bone-density compared to PT. Results for post-operative pain are inconclusive.

  18. Vehicle Exposure and Spinal Musculature Fatigue in Military Warfighters: A Meta-Analysis.

    PubMed

    Kollock, Roger O; Games, Kenneth E; Wilson, Alan E; Sefton, JoEllen M

    2016-11-01

     Spinal musculature fatigue from vehicle exposure may place warfighters at risk for spinal injuries and pain. Research on the relationship between vehicle exposure and spinal musculature fatigue is conflicting. A better understanding of the effect of military duty on musculoskeletal function is needed before sports medicine teams can develop injury-prevention programs.  To determine if the literature supports a definite effect of vehicle exposure on spinal musculature fatigue.  We searched the MEDLINE, Military & Government Collection (EBSCO), National Institute for Occupational Safety and Health Technical Information Center, PubMed, and Web of Science databases for articles published between January 1990 and September 2015.  To be included, a study required a clear sampling method, preexposure and postexposure assessments of fatigue, a defined objective measurement of fatigue, a defined exposure time, and a study goal of exposing participants to forces related to vehicle exposure.  Sample size, mean preexposure and postexposure measures of fatigue, vehicle type, and exposure time.  Six studies met the inclusion criteria. We used the Scottish Intercollegiate Guidelines Network algorithm to determine the appropriate tool for quality appraisal of each article. Unweighted random-effects model meta-analyses were conducted, and a natural log response ratio was used as the effect metric. The overall meta-analysis demonstrated that vehicle exposure increased fatigue of the spinal musculature (P = .03; natural log response ratio = -0.22, 95% confidence interval = -0.42, -0.02). Using the spinal region as a moderator, we observed that vehicle ride exposure significantly increased fatigue at the lumbar musculature (P = .02; natural log response ratio = -0.27, 95% confidence interval = -0.50, -0.04) but not at the cervical or thoracic region.  Vehicle exposure increased fatigue at the lumbar region.

  19. Vehicle Exposure and Spinal Musculature Fatigue in Military Warfighters: A Meta-Analysis

    PubMed Central

    Kollock, Roger O.; Games, Kenneth E.; Wilson, Alan E.; Sefton, JoEllen M.

    2016-01-01

    Context: Spinal musculature fatigue from vehicle exposure may place warfighters at risk for spinal injuries and pain. Research on the relationship between vehicle exposure and spinal musculature fatigue is conflicting. A better understanding of the effect of military duty on musculoskeletal function is needed before sports medicine teams can develop injury-prevention programs. Objective: To determine if the literature supports a definite effect of vehicle exposure on spinal musculature fatigue. Data Sources: We searched the MEDLINE, Military & Government Collection (EBSCO), National Institute for Occupational Safety and Health Technical Information Center, PubMed, and Web of Science databases for articles published between January 1990 and September 2015. Study Selection: To be included, a study required a clear sampling method, preexposure and postexposure assessments of fatigue, a defined objective measurement of fatigue, a defined exposure time, and a study goal of exposing participants to forces related to vehicle exposure. Data Extraction: Sample size, mean preexposure and postexposure measures of fatigue, vehicle type, and exposure time. Data Synthesis: Six studies met the inclusion criteria. We used the Scottish Intercollegiate Guidelines Network algorithm to determine the appropriate tool for quality appraisal of each article. Unweighted random-effects model meta-analyses were conducted, and a natural log response ratio was used as the effect metric. The overall meta-analysis demonstrated that vehicle exposure increased fatigue of the spinal musculature (P = .03; natural log response ratio = −0.22, 95% confidence interval = −0.42, −0.02). Using the spinal region as a moderator, we observed that vehicle ride exposure significantly increased fatigue at the lumbar musculature (P = .02; natural log response ratio = −0.27, 95% confidence interval = −0.50, −0.04) but not at the cervical or thoracic region. Conclusions: Vehicle exposure increased fatigue at the lumbar region. PMID:28068167

  20. Principles of management of osteometabolic disorders affecting the aging spine.

    PubMed

    Hadjipavlou, Alexander G; Katonis, Paul G; Tzermiadianos, Michael N; Tsoukas, George M; Sapkas, George

    2003-10-01

    Osteoporosis is the most common contributing factor of spinal fractures, which characteristically are not generally known to produce spinal cord compression symptoms. Recently, an increasing number of medical reports have implicated osteoporotic fractures as a cause of serious neurological deficit and painful disabling spinal deformities. This has been corroborated by the present authors as well. These complications are only amenable to surgical management, requiring instrumentation. Instrumenting an osteoporotic spine, although a challenging task, can be accomplished if certain guidelines for surgical techniques are respected. Neurological deficits respond equally well to an anterior or posterior decompression, provided this is coupled with multisegmental fixation of the construct. With the steady increase in the elderly population, it is anticipated that the spine surgeon will face serious complications of osteoporotic spines more frequently. With regard to surgery, however, excellent correction of deformities can be achieved, by combining anterior and posterior approaches. Paget's disease of bone (PD) is a non-hormonal osteometabolic disorder and the spine is the second most commonly affected site. About one-third of patients with spinal involvement exhibit symptoms of clinical stenosis. In only 12-24% of patients with PD of the spine is back pain attributed solely to PD, while in the majority of patients, back pain is either arthritic in nature or a combination of a pagetic process and coexisting arthritis. In this context, one must be certain before attributing low back pain to PD exclusively, and antipagetic medical treatment alone may be ineffective. Neural element dysfunction may be attributed to compressive myelopathy by pagetic bone overgrowth, pagetic intraspinal soft tissue overgrowth, ossification of epidural fat, platybasia, spontaneous bleeding, sarcomatous degeneration and vertebral fracture or subluxation. Neural dysfunction can also result from spinal ischemia when blood is diverted by the so-called "arterial steal syndrome". Because the effectiveness of pharmacologic treatment for pagetic spinal stenosis has been clearly demonstrated, surgical decompression should only be instituted after failure of antipagetic medical treatment. Surgery is indicated as a primary treatment when neural compression is secondary to pathologic fractures, dislocations, spontaneous epidural hematoma, syringomyelia, platybasia, or sarcomatous transformation. Five classes of drugs are available for the treatment of PD. Bisphosphonates are the most popular antipagetic drug and several forms have been investigated.

  1. STP Position Paper: Recommended ("Best") Practices for Sampling, Processing, and Analysis of the Peripheral Nervous System (Nerves and Somatic and Autonomic Ganglia) during Nonclinical Toxicity Studies.

    PubMed

    Bolon, Brad; Krinke, Georg; Butt, Mark T; Rao, Deepa B; Pardo, Ingrid D; Jortner, Bernard S; Garman, Robert H; Jensen, Karl; Andrews-Jones, Lydia; Morrison, James P; Sharma, Alok K; Thibodeau, Michael S

    2018-01-01

    Peripheral nervous system (PNS) toxicity is surveyed inconsistently in nonclinical general toxicity studies. These Society of Toxicologic Pathology "best practice" recommendations are designed to ensure consistent, efficient, and effective sampling, processing, and evaluation of PNS tissues for four different situations encountered during nonclinical general toxicity (screening) and dedicated neurotoxicity studies. For toxicity studies where neurotoxicity is unknown or not anticipated (situation 1), PNS evaluation may be limited to one sensorimotor spinal nerve. If somatic PNS neurotoxicity is suspected (situation 2), analysis minimally should include three spinal nerves, multiple dorsal root ganglia, and a trigeminal ganglion. If autonomic PNS neuropathy is suspected (situation 3), parasympathetic and sympathetic ganglia should be assessed. For dedicated neurotoxicity studies where a neurotoxic effect is expected (situation 4), PNS sampling follows the strategy for situations 2 and/or 3, as dictated by functional or other compound/target-specific data. For all situations, bilateral sampling with unilateral processing is acceptable. For situations 1-3, PNS is processed conventionally (immersion in buffered formalin, paraffin embedding, and hematoxylin and eosin staining). For situation 4 (and situations 2 and 3 if resources and timing permit), perfusion fixation with methanol-free fixative is recommended. Where PNS neurotoxicity is suspected or likely, at least one (situations 2 and 3) or two (situation 4) nerve cross sections should be postfixed with glutaraldehyde and osmium before hard plastic resin embedding; soft plastic embedding is not a suitable substitute for hard plastic. Special methods may be used if warranted to further characterize PNS findings. Initial PNS analysis should be informed, not masked ("blinded"). Institutions may adapt these recommendations to fit their specific programmatic requirements but may need to explain in project documentation the rationale for their chosen PNS sampling, processing, and evaluation strategy.

  2. Persistent Iliosacral Joint Syndrome following Instrumentation to the Sacropelvis in Patients with Adult Spinal Deformity.

    PubMed

    Diesing, Daniela; Franke, Joerg; Tschoeke, Sven Kevin; Schultheiß, Rolf; Scheufler, Kai Michael

    2018-05-31

     Persistent sacroiliac joint syndrome (PSIJS) may complicate adult spinal deformity surgery (ASDS). This study assesses the relationship between clinical/morphometric parameters and PSIJS following ASDS including pelvic fixation and the therapeutic efficacy of secondary iliosacral fusion (ISF).  Perioperative health-related quality of life (HRQOL) outcomes (Oswestry Disability Index, Short Form 12-item health survey, version 2 scores) at 6, 12, and 24 months, and radiographic studies were analyzed retrospectively in a cohort of 71 consecutive patients undergoing ASDS. PSIJS was confirmed in nine individuals (12.7%) by placebo-controlled dual sacroiliac joint (SIJ) blocks. The relationships between global and regional spinopelvic morphometry, PSIJS, and HRQOL outcomes were assessed by logistic regression and receiver operating characteristic curve (ROC) analysis.  PSIJS, independently causing significantly reduced improvement in HRQOL scores ( p  < 0.001) 6 months postoperatively, warranted secondary ISF in nine patients (12.7%) within 12 months of index surgery, without evidence of progressive SIJ arthrosis, pseudarthrosis, or hardware issues. Eight of nine patients undergoing secondary ISF reported≥ 70% pain reduction at 24 months. Logistic regression/ROC analysis revealed a close association between PSIJS and nonharmonious postoperative L4-S1 fractional lordosis ( p  < 0.0001), pelvic incidence angle > 53 degrees, hip arthrosis, and preexistent advanced SIJ arthrosis ( p  < 0.01).  PSIJS may negatively impact the clinical outcome of ASDS. Recurrent preoperative SIJ syndrome requiring interventional treatment, preexisting hip and SIJ arthrosis, insufficient restoration of L4-S1 fractional lordosis, and high pelvic incidence predispose to PSIJS. PSIJS may potentially be avoided by restoring physiologic lumbosacral geometry and S2 sacral alar-iliac screw fixation during index surgery. Secondary ISF appears to be effective in reducing pain and physical impairment due to PSIJS. Georg Thieme Verlag KG Stuttgart · New York.

  3. Assistance of intraoperative microvascular Doppler in the surgical obliteration of spinal dural arteriovenous fistula: cases description and technical considerations.

    PubMed

    Iacopino, D G; Conti, A; Giusa, M; Cardali, S; Tomasello, F

    2003-02-01

    Intraoperative microvascular Doppler may be valuable in assisting in the surgical obliteration of dural arteriovenous fistula of the spinal cord. It enables identification, through flow spectrum analysis, of the anatomic components and haemodynamic features of this type of vascular malformation. In two cases, intraoperative microvascular Doppler was used to assist in the surgical obliteration of dural arteriovenous fistula of the spinal cord. The fistulas were identified prior to the dura opening, and for this only minimally invasive surgery was required. Direct recordings of the arterialised draining vein and the nidus of the fistula demonstrated a pathological spectrum caused by the arterial supply and the disturbed venous outflow in which a high-resistance flow pattern and low diastolic flow resembling an arterial-like flow velocity were observed. The fistulas were obliterated by interruption of the draining vein, and Doppler measurements provided information on flow velocity changes in the medullary veins from an arterial to a venous pattern. The absence of any residual flow in the draining vein confirmed successful haemodynamic treatment. Intraoperative microvascular Doppler recording is valuable assistance in surgical closure of spinal arteriovenous fistula.

  4. Setting the pace: insights and advancements gained while preparing for an FES bike race.

    PubMed

    McDaniel, John; Lombardo, Lisa M; Foglyano, Kevin M; Marasco, Paul D; Triolo, Ronald J

    2017-11-17

    The reduction in physical activity following a spinal cord injury often leads to a decline in mental and physical health. Developing an exercise program that is effective and enjoyable is paramount for this population. Although functional electrical stimulation (FES) stationary cycling has been utilized in rehabilitation settings, implementing an overground cycling program for those with spinal cord injuries has greater technical challenges. Recently our laboratory team focused on training five individuals with compete spinal cord injuries utilizing an implanted pulse generator for an overground FES bike race in CYBATHLON 2016 held in Zurich, Switzerland. The advancements in muscle strength and endurance and ultimately cycling power our pilots made during this training period not only helped propel our competing pilot to win gold at the CYBATHLON 2016, but allowed our pilots to ride their bikes outside within their communities. Such a positive outcome has encouraged us to put effort into developing more widespread use of FES overground cycling as a rehabilitative tool for those with spinal cord injuries. This commentary will describe our approach to the CYBATHLON 2016 including technological advancements, bike design and the training program.

  5. Assessing denoising strategies to increase signal to noise ratio in spinal cord and in brain cortical and subcortical regions

    NASA Astrophysics Data System (ADS)

    Maugeri, L.; Moraschi, M.; Summers, P.; Favilla, S.; Mascali, D.; Cedola, A.; Porro, C. A.; Giove, F.; Fratini, M.

    2018-02-01

    Functional Magnetic Resonance Imaging (fMRI) based on Blood Oxygenation Level Dependent (BOLD) contrast has become one of the most powerful tools in neuroscience research. On the other hand, fMRI approaches have seen limited use in the study of spinal cord and subcortical brain regions (such as the brainstem and portions of the diencephalon). Indeed obtaining good BOLD signal in these areas still represents a technical and scientific challenge, due to poor control of physiological noise and to a limited overall quality of the functional series. A solution can be found in the combination of optimized experimental procedures at acquisition stage, and well-adapted artifact mitigation procedures in the data processing. In this framework, we studied two different data processing strategies to reduce physiological noise in cortical and subcortical brain regions and in the spinal cord, based on the aCompCor and RETROICOR denoising tools respectively. The study, performed in healthy subjects, was carried out using an ad hoc isometric motor task. We observed an increased signal to noise ratio in the denoised functional time series in the spinal cord and in the subcortical brain region.

  6. Improved Intermittent-clamped Drainage in Lower Lumbar Internal Fixation: A Randomized Prospective Study

    PubMed Central

    Hao, Qing-Ying; Liu, Chu-Yin; Fu, Chan-Juan; Zhang, Xiao-Hua; Tan, Ming-Sheng

    2016-01-01

    Background: Continuous negative pressure drainage (CNPD) is widely used after lower lumbar internal fixation; however, it may cause tremendous blood loss and lead to postoperative hemorrhagic anemia. The present study explored the efficacy and safety of improved intermittent-clamped drainage (ICD) for lower lumbar internal fixation. Methods: This was a prospective study that included 156 patients with decompression of the spinal canal and internal fixation for the first time from January 2012 to December 2014. The patients were randomly divided into ICD group and CNPD group, and each group had 78 cases. A drainage tube was placed under the deep fascia in all patients within 10 min after the commencement of wound closure. The postoperative drainage amount at different time points, the hemoglobin level, and postoperative complications were recorded and compared between the two groups. Shapiro-Wilk test, independent samples t-test, and Mann-Whitney U-test were used in this study. Results: The drainage amount was significantly reduced in the ICD group, as compared with the CNPD group (Z = 10.74, P < 0.01). The mean total drainage amount (in ml) of the single-segment and two-segment procedures was significantly greater in the CNPD group than the ICD group (Z = 10.63 and 10.75, respectively; P < 0.01). For the adverse events, there was no significant difference in postoperative temperature, wound problem, and complications between the two groups. Conclusions: The present study showed a statistically significant reduction in postoperative drainage amount between ICD and CNPD groups, and ICD is an effective, convenient, and safe method for routine use in lower lumbar surgery. It is essential to focus on the effect of clamping drainage with long-segment surgical procedure and complex lumbar disease in the further investigation, as well as the effect of clamping on long-term functional outcomes. PMID:27900992

  7. A case of deep infection after instrumentation in dorsal spinal surgery: the management with antibiotics and negative wound pressure without removal of fixation.

    PubMed

    Dobran, Mauro; Mancini, Fabrizio; Nasi, Davide; Scerrati, Massimo

    2017-07-28

    Until today the role of spinal instrumentation in the presence of a wound infection has been widely discussed and recently many authors leave the hardware in place with appropriate antibiotic therapy. This is a case of a 65-year-old woman suffering from degenerative scoliosis and osteoporotic multiple vertebral collapses treated with posterior dorsolumbar stabilisation with screws and rods. Four months later, skin necrosis and infection appeared in the cranial wound with exposure of the rods. A surgical procedure of debridement of the infected tissue and package with a myocutaneous trapezius muscle flap was performed. One week after surgery, negative pressure wound therapy was started on the residual skin defect. The wound healed after 2 months. The aim of this case report is to focus on the utility of this method even in the case of hardware exposure and infection. This may help avoid removing instrumentation and creating instability. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Design of a surgical instrument for removing bone to provide screw access to a spinal fusion cage.

    PubMed

    Jabbary Aslani, F; Hukins, D W L; Shepherd, D E T; Parry, J J; Fennell, A J; Lambell, S

    2012-01-01

    A surgical instrument to aid implantation of a range of lumbar spinal fusion cages has been developed. Once the cage is in position, the entrance to screw holes is partially blocked by the edge of the vertebral body. In order to insert fixation screws to secure the cage between the vertebrae, some part of the blocking edge has to be removed. Rongeurs are currently being used, but they can be time consuming and have the disadvantage that they may remove more bone than is necessary and may cause damage to the fusion cage if not used with care. In addition, access around some of the screw holes may be difficult. The aim of this instrument was to overcome these shortcomings. This paper describes the design of a surgical instrument for cutting edges from vertebral bodies. The development and evaluation of concept designs are presented and discussed. Potential risks were considered and modifications were performed on the selected concept. Functional prototypes were manufactured and tested on sheep lumbar vertebrae. The results showed that the newly designed cutting instrument functions as required and removes the required amount of bone from the vertebral body edge.

  9. THE NISSL SUBSTANCE OF LIVING AND FIXED SPINAL GANGLION CELLS

    PubMed Central

    Deitch, Arline D.; Moses, Montrose J.

    1957-01-01

    Living chick spinal ganglion neurons grown for 19 to 25 days in vitro were photographed with a color-translating ultraviolet microscope (UV-91) at 265, 287, and 310 mµ. This instrument was unique in permitting rapid accumulation of ultraviolet information with minimal damage to the cell. In the photographs taken at 265 mµ of the living neurons, discrete ultraviolet-absorbing cytoplasmic masses were observed which were found to be virtually unchanged in appearance after formalin fixation. These were identical with the Nissl bodies of the same cells seen after staining with basic dyes. The correlation of ultraviolet absorption, ribonuclease extraction, and staining experiments with acid and basic dyes confirmed the ribonucleoprotein nature of these Nissl bodies in the living and fixed cells. No change in distribution or concentration of ultraviolet-absorbing substance was observed in the first 12 ultraviolet photographs of a neuron, and it is concluded that the cells had not been subjected to significant ultraviolet damage during the period of photography. On the basis of these observations, as well as previous findings with phase contrast microscopy, it is concluded that Nissl bodies preexist in the living neuron as discrete aggregates containing high concentrations of nucleoprotein. PMID:13438929

  10. Distraction of facets with intraarticular spacers as treatment for lumbar canal stenosis: report on a preliminary experience with 21 cases.

    PubMed

    Goel, Atul; Shah, Abhidha; Jadhav, Madan; Nama, Santhosh

    2013-12-01

    The authors report their experience in treating 21 patients by using a novel form of treatment of lumbar degenerative disease that leads to canal stenosis. The surgery involved distraction of the facets using specially designed Goel intraarticular spacers and was aimed at arthrodesis of the spinal segment in a distracted position. The operation is based on the premise that subtle and longstanding facet instability, joint space reduction, and subsequent facet override had a profound and primary influence in the pathogenesis of degenerative lumbar canal stenosis. The surgical technique and the rationale for treatment are discussed. Between April 2006 and January 2011, 21 cases of lumbar degenerative disease resulting in characteristic lumbar canal stenosis were treated in the authors' department with the proposed technique. The patients were prospectively analyzed. There were 15 men and 6 women who ranged in age from 48 to 71 years (mean 58 years). Nine patients underwent 1-level and 12 patients underwent 2-level treatment. Surgery involved wide opening of the articular joint, denuding of the articular capsule/endplate cartilage, distraction of the facets, and forced impaction of Goel intraarticular spacers. Bone graft pieces obtained by sectioning the spinous processes were placed within and over the joint and in the midline over the adequately prepared host area of laminae. The Oswestry Disability Index and visual analog scale were used to clinically assess the patients before and after surgery and at follow-up. The alterations in the physical architecture of spinal canal and intervertebral foramen dimensions were evaluated before and after placement of the intrafacet implant and after at least 6 months of follow-up. All patients had varying degrees of relief from symptoms of local back pain and radiculopathy. Impaction of spacers within the facet joints resulted in an increase in the spinal canal and intervertebral root canal dimensions (mean 2.33 mm), reduction of buckling of the ligamentum flavum, and reduction of the extent of bulge of the disc into the spinal canal. The procedure resulted in firm stabilization and fixation of the spinal segment and provided a ground for arthrodesis. No patient worsened neurologically after treatment. During the follow-up period, all patients had evidence of segmental bone fusion. No patient underwent reexploration or further surgery of the lumbar spine. Impaction of the spacers within the articular cavity after facet distraction resulted in reversal of several effects of spine degeneration that had caused spinal and root canal stenosis. The safe, firm, and secure stabilization at the fulcrum of lumbar spinal movements provided a ground for segmental spinal arthrodesis. The immediate postoperative and lasting recovery from symptoms suggests the validity of the procedure.

  11. Eye Movement Control during Reading: II. Frequency of Refixating a Word. Technical Report No. 469.

    ERIC Educational Resources Information Center

    McConkie, G. W.; And Others

    As part of a series of studies describing the oculomotor behavior of skilled readers, a study investigated whether a word refixation curve exists. Subjects, 66 college students fixating over 40,000 times, read lines of text from a computer screen and were instructed to read for meaning without regard to errors. Results of eye movement control…

  12. Muscle gap approach under a minimally invasive channel technique for treating long segmental lumbar spinal stenosis

    PubMed Central

    Bin, Yang; De cheng, Wang; wei, Wang Zong; Hui, Li

    2017-01-01

    Abstract This study aimed to compare the efficacy of muscle gap approach under a minimally invasive channel surgical technique with the traditional median approach. In the Orthopedics Department of Traditional Chinese and Western Medicine Hospital, Tongzhou District, Beijing, 68 cases of lumbar spinal canal stenosis underwent surgery using the muscle gap approach under a minimally invasive channel technique and a median approach between September 2013 and February 2016. Both approaches adopted lumbar spinal canal decompression, intervertebral disk removal, cage implantation, and pedicle screw fixation. The operation time, bleeding volume, postoperative drainage volume, and preoperative and postoperative visual analog scale (VAS) score and Japanese Orthopedics Association score (JOA) were compared between the 2 groups. All patients were followed up for more than 1 year. No significant difference between the 2 groups was found with respect to age, gender, surgical segments. No diversity was noted in the operation time, intraoperative bleeding volume, preoperative and 1 month after the operation VAS score, preoperative and 1 month after the operation JOA score, and 6 months after the operation JOA score between 2 groups (P > .05). The amount of postoperative wound drainage (260.90 ± 160 mL vs 447.80 ± 183.60 mL, P < .001) and the VAS score 6 months after the operation (1.71 ± 0.64 vs 2.19 ± 0.87, P = .01) were significantly lower in the muscle gap approach group than in the median approach group (P < .05). In the muscle gap approach under a minimally invasive channel group, the average drainage volume was reduced by 187 mL, and the average VAS score 6 months after the operation was reduced by an average of 0.48. The muscle gap approach under a minimally invasive channel technique is a feasible method to treat long segmental lumbar spinal canal stenosis. It retains the integrity of the posterior spine complex to the greatest extent, so as to reduce the adjacent spinal segmental degeneration and soft tissue trauma. Satisfactory short-term and long-term clinical results were obtained. PMID:28796075

  13. Ependymal cells variations in the central canal of the rat spinal cord filum terminale: an ultrastructural investigation.

    PubMed

    Mitro, A; Gallatz, K; Palkovits, M; Kiss, A

    2013-04-01

    The ependymal cells, considered today as an active participant in neuroendocrine functions, were investigated by electron microscopy in the central canal of the lowest spinal cord, the filum terminale (FT), in adult rats. In this area of the spinal cord, the central canal is covered by a heterogeneous population of ependymal cells. The aim of the present work was to compare the regional features of the ependymal cells in two different parts of the FT with a special regard to their ultrastructure. Two parts of the FT were selected for the ultrastructural observations: the rostral (rFT) and the caudal (cFT) ones. The rTF was removed at the level of the immediate continuation of the conus medullaris, while the cFT 30 mm further caudally. After formaldehyde fixation, the spinal cord was removed and cut into small blocks for electron microscopic processing. The material was embedded into durcupan, contrasted with uranyl acetate, lead citrate as well as osmium tetroxide, and investigated under JEOL 1200 EX electron microscope. In the rFT, the ependymal lining is pseudostratified and one-layered in the cFT, whereas the shape of the ependymal cells may vary from cuboidal to flatten in the rostro-caudal direction. The basal membrane of many ependymal cells possesses deep invaginations, so called "filum terminale labyrinths". Many neuronal processes occur in the pericanalicular neuropil. In contrast to the rFT, the cFT is less rich in the neuropil particles. Some of the ependymal cells concurrently reach both the intracanalicular and extracanalicular cerebrospinal fluid (CSF), thus they may represent a new variant of the ependymal cells designated as "bridge cells of the FT". The present data indicate that the FT ependymal cells exhibit clear differences in anatomy as well as ultrastructure that may reflect their distinct functional activity. Therefore, observations presented here may serve for the better understanding of the physiological role of the individual ependymal areas in this special portion of the rat spinal cord.

  14. Restoring tactile and erogenous penile sensation in low-spinal-lesion patients: procedural and technical aspects following 43 TOMAX nerve transfer procedures.

    PubMed

    Overgoor, Max L E; de Jong, Tom P V M; Kon, Moshe

    2014-08-01

    The "TOMAX" (TO MAX-imize sensation, sexuality, and quality of life) procedure restores genital sensation in men with low spinal lesions, improving sexual health, as shown previously. It connects the dorsal nerve of the penis to the intact ipsilateral ilioinguinal nerve, unilaterally or bilaterally. This study reports on the technical aspects based on 43 TOMAX nerve transfers. In 40 patients with no penile but intact groin sensation, 43 nerve transfers were performed. Data on patient selection, surgical history, anatomy of the ilioinguinal nerve and dorsal nerve of the penis, unilateral or bilateral surgery, surgical technique, complications, and patient information were collected prospectively. Regardless of origin, all patients with no penile but good groin sensation are eligible for the procedure, provided the ilioinguinal nerve is not damaged because of former inguinal surgery or absent because of anatomical variations. Selection of a unilateral or bilateral procedure depends on the presence or absence of reflex erections and bulbocavernosus reflex. Preliminary experience with the first three bilateral cases shows that it is technically feasible, with encouraging results. The surgical technique has evolved (described in detail, including video) to enhance outcome and reduce complications. Patients are better informed, resulting in realistic expectations. This article synthesizes the procedural and technical experience of 43 TOMAX nerve transfers. Anyone skilled in peripheral nerve surgery and microsurgery can adopt this concept and further develop it. The TOMAX procedure can then be used to restore erogenous penile sensation and improve the quality of sexual health in patients with absent penile but good groin sensation.

  15. [Clinical studies of pedicle screw-rod fixation of thoracolumbar burst fractures through posterior unilateral approach after vertebrae corpectomy fusion].

    PubMed

    Hua, Yong-jun; Wang, Ren-yan; Guo, Zhi-hui; Shu, Cun-hong; Li, Chao-hua

    2016-01-01

    To compare the clinical curative effect of thoracolumbar burst fracture treated by the posterior unilateral approach corpectomy fusion screw-rod fixation and anterior corpectomy bone fusion screw plate fixation. From January 2008 to May 2014,36 cases of thoracolumbar burst fracture underwent operation of decompression, fusion, and internal fixation was retrospective analyzed. Among them, 16 patients were treated through posterior approach as posterior group, including 13 males and 3 females aged from 37 to 62 years old; 9 cases caused by falling injury, 3 cases by traffic accident injury,4 cases by heavy aboved;the injury segment was on T₁₂ in 2 cases, L₁ in 5 cases, L₂ in 7 cases, L₃ in 2 cases; according ASIA grade, 3 cases were grade A, 2 cases were grade B, 2 cases were grade C, 5 cases were grade D, 4 cases were grade E; the time between injury and operation ranged from 5 to 15 days. Other 20 patients were treated through anterior-lateral approach as anterior-lateral group, including 15 males and 5 females with age from 27 to 62 years old; 12 cases caused by falling injury, 4 cases by traffic accident injury, 4 cases by heavy aboved; the injury segment was on T₁₂ in 2 cases, L₁, in 7 cases, L₂ in 9 cases, L₃ in 2 cases; for ASIA grade: 4 cases were grade A, 2 cases were grade B, 4 cases were grade C, 6 cases were grade D, 4 cases were grade E; the time between injury and operation ranged from 4 to 12 days. The operation time, bleeding during operation and postoperative drainage volume were observed in two groups,and the changes of nerve function of ASIA grade, clinical efficacy,improved degree of thoracic and lumbar lordosis,and bony fusion were compared between two groups. All patients were followed up from 12 to 24 months with an average of (15.8 ± 3.3) months. The operation time, bleeding during operation, and postoperative drainage volume had no significant different between two groups (P > 0.05). As compared with preoperative, ASIA grade of two groups at last follow-up had statistically significantly different (P < 0.01), the neural function of two groups after operation was recovered for different extent. The JOA score of two groups was compared between last follow-up and preoperative, the difference had statistically significant (P < 0.01), the two groups showed good clinical effect. The clinical results of ASIA grade, JOA score and RIS had no significant differences between two groups. All patients of two groups were obtained fusion. Thoracic and lumbar lordosis angle improvement degree had no significant difference between two groups ,it bad significant difference had statistical significance compared with preoperative, the two approaches could effectively restore the spinal sequence. For patients with thoracolumbar burst fracture just treated by anterior decompression and reconstruction of anterior column, according to the degree of operation performer' skill proficiency and the patient' condition to choose, but for patients must performed the spinal canal decompression anterior and posterior, the three column-reconstruction to required anterior-posterior approach, the posterior unilateral approach corpectomy fusion screw-rod fixation obviously shorten operation time, reduce the operation wound, it is worth the clinical promotion.

  16. Device-Training for Individuals with Thoracic and Lumbar Spinal Cord Injury Using a Powered Exoskeleton for Technically Assisted Mobility: Achievements and User Satisfaction

    PubMed Central

    Gillner, Annett; Borgwaldt, Nicole; Kroll, Sylvia; Roschka, Sybille

    2016-01-01

    Objective. Results of a device-training for nonambulatory individuals with thoracic and lumbar spinal cord injury (SCI) using a powered exoskeleton for technically assisted mobility with regard to the achieved level of control of the system after training, user satisfaction, and effects on quality of life (QoL). Methods. Observational single centre study with a 4-week to 5-week intensive inpatient device-training using a powered exoskeleton (ReWalk™). Results. All 7 individuals with SCI who commenced the device-training completed the course of training and achieved basic competences to use the system, that is, the ability to stand up, sit down, keep balance while standing, and walk indoors, at least with a close contact guard. User satisfaction with the system and device-training was documented for several aspects. The quality of life evaluation (SF-12v2™) indicated that the use of the powered exoskeleton can have positive effects on the perception of individuals with SCI regarding what they can achieve physically. Few adverse events were observed: minor skin lesions and irritations were observed; no falls occurred. Conclusions. The device-training for individuals with thoracic and lumbar SCI was effective and safe. All trained individuals achieved technically assisted mobility with the exoskeleton while still needing a close contact guard. PMID:27610382

  17. Where and When to Cut? Fluorescein Guidance for Brain Stem and Spinal Cord Tumor Surgery-Technical Note.

    PubMed

    Molina, Eric Suero; Stummer, Walter

    2017-12-29

    Spinal cord and brain stem lesions require a judicious approach with an optimized trajectory due to a clustering of functions on their surfaces. Intraoperative mapping helps locate function. To confidently locate such lesions, neuronavigation alone lacks the desired accuracy and is of limited use in the spinal cord. To evaluate the clinical value of fluoresceins for initial delineation of such critically located lesions. We evaluated fluorescein guidance in the surgical resection of lesions with blood-brain barrier disruption demonstrating contrast enhancement in magnet resonance imaging in the spinal cord and in the brain stem in 3 different patients. Two patients harbored a diffuse cervical and thoracic spinal cord lesion, respectively. Another patient suffered metastatic lesions in the brain stem and at the floor of the fourth ventricle. Low-dose fluorescein (4 mg/kg body weight) was applied after anesthesia induction and visualized using the Zeiss Pentero 900 Yellow560 filter (Carl Zeiss, Oberkochen, Germany). Fluorescein was helpful for locating lesions and for defining the best possible trajectory. During resection, however, we found unspecific propagation of fluorescein within the brain stem up to 6 mm within 3 h after application. As these lesions were otherwise distinguishable from surrounding tissue, monitoring resection was not an issue. Fluorescein guidance is a feasible tool for defining surgical entry zones when aiming for surgical removal of spinal cord and brain stem lesions. Unselective fluorescein extravasation cautions against using such methodology for monitoring completeness of resection. Providing the right timing, a window of pseudoselectivity could increase fluoresceins' clinical value in these cases. © Congress of Neurological Surgeons 2017.

  18. Ultrafast dynamic computed tomography myelography for the precise identification of high-flow cerebrospinal fluid leaks caused by spiculated spinal osteophytes.

    PubMed

    Thielen, Kent R; Sillery, John C; Morris, Jonathan M; Hoxworth, Joseph M; Diehn, Felix E; Wald, John T; Rosebrock, Richard E; Yu, Lifeng; Luetmer, Patrick H

    2015-03-01

    Precise localization and understanding of the origin of spontaneous high-flow spinal CSF leaks is required prior to targeted treatment. This study demonstrates the utility of ultrafast dynamic CT myelography for the precise localization of high-flow CSF leaks caused by spiculated spinal osteophytes. This study reports a series of 14 patients with high-flow CSF leaks caused by spiculated spinal osteophytes who underwent ultrafast dynamic CT myelography between March 2009 and December 2010. There were 10 male and 4 female patients, with an average age of 49 years (range 37-74 years). The value of ultrafast dynamic CT myelography in depicting the CSF leak site was qualitatively assessed. In all 14 patients, ultrafast dynamic CT myelography was technically successful at precisely demonstrating the site of the CSF leak, the causative spiculated osteophyte piercing the dura, and the relationship of the implicated osteophyte to adjacent structures. Leak sites included 3 cervical, 11 thoracic, and 0 lumbar levels, with 86% of the leaks occurring from C-5 to T-7. Information obtained from the ultrafast dynamic CT myelogram was considered useful in all treated CSF leaks. Spinal osteophytes piercing the dura are a more frequent cause of high-flow CSF leaks than previously recognized. Ultrafast dynamic CT myelography adds value beyond standard dynamic myelography or digital subtraction myelography in the diagnosis and anatomical characterization of high-flow spinal CSF leaks caused by these osteophytes. This information allows for appropriate planning for percutaneous or surgical treatment.

  19. Surgical management of spinal intramedullary tumors: radical and safe strategy for benign tumors.

    PubMed

    Takami, Toshihiro; Naito, Kentaro; Yamagata, Toru; Ohata, Kenji

    2015-01-01

    Surgery for spinal intramedullary tumors remains one of the major challenges for neurosurgeons, due to their relative infrequency, unknown natural history, and surgical difficulty. We are sure that safe and precise resection of spinal intramedullary tumors, particularly encapsulated benign tumors, can result in acceptable or satisfactory postoperative outcomes. General surgical concepts and strategies, technical consideration, and functional outcomes after surgery are discussed with illustrative cases of spinal intramedullary benign tumors such as ependymoma, cavernous malformation, and hemangioblastoma. Selection of a posterior median sulcus, posterolateral sulcus, or direct transpial approach was determined based on the preoperative imaging diagnosis and careful inspection of the spinal cord surface. Tumor-cord interface was meticulously delineated in cases of benign encapsulated tumors. Our retrospective functional analysis of 24 consecutive cases of spinal intramedullary ependymoma followed for at least 6 months postoperatively demonstrated a mean grade on the modified McCormick functional schema of 1.8 before surgery, deteriorating significantly to 2.6 early after surgery (< 1 month after surgery), and finally returning to 1.7 in the late postoperative period (> 6 months after surgery). The risk of functional deterioration after surgery should be taken into serious consideration. Functional deterioration after surgery, including neuropathic pain even long after surgery, significantly affects patient quality of life. Better balance between tumor control and functional preservation can be achieved not only by the surgical technique or expertise, but also by intraoperative neurophysiological monitoring, vascular image guidance, and postoperative supportive care. Quality of life after surgery should inarguably be given top priority.

  20. Real-time ultrasound-guided spinal anesthesia using the SonixGPS® needle tracking system: a case report.

    PubMed

    Wong, Simon W; Niazi, Ahtsham U; Chin, Ki J; Chan, Vincent W

    2013-01-01

    The SonixGPS® is an electromagnetic needle tracking system for ultrasound-guided needle intervention. Both current and predicted needle tip position are displayed on the ultrasound screen in real-time, facilitating needle-beam alignment and guidance to the target. This case report illustrates the use of the SonixGPS system for successful performance of real-time ultrasound-guided spinal anesthesia in a patient with difficult spinal anatomy. A 67-yr-old male was admitted to our hospital to undergo revision of total right hip arthroplasty. His four previous arthroplasties for hip revision were performed under general anesthesia because he had undergone L3-L5 instrumentation for spinal stenosis. The L4-L5 interspace was viewed with the patient in the left lateral decubitus position. A 19G 80-mm proprietary needle (Ultrasonix Medical Corp, Richmond, BC, Canada) was inserted and directed through the paraspinal muscles to the ligamentum flavum in plane to the ultrasound beam. A 120-mm 25G Whitacre spinal needle was then inserted through the introducer needle in a conventional fashion. Successful dural puncture was achieved on the second attempt, as indicated by a flow of clear cerebrospinal fluid. The patient tolerated the procedure well, and the spinal anesthetic was adequate for the duration of the surgery. The SonixGPS is a novel technology that can reduce the technical difficulty of real-time ultrasound-guided neuraxial blockade. It may also have applications in other advanced ultrasound-guided regional anesthesia techniques where needle-beam alignment is critical.

  1. Structure and function of Frankia vesicles in denitrogen fixation by actinorhizal plants: Annual technical progress report for period January 1, 1987-November 15, 1987

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Torrey, J.G.

    1987-11-20

    Frankia is a filamentous soil bacterium of the Actinomycetales that is capable of fixation of atmospheric dinitrogen both in the free-living state and within root modules of a number of woody dicotyledonous plants in a symbiotic process. The bacterium is of special interest because of its genetic capacity to differentiate terminal swellings of the hyphal filaments called vesicles. Vesicles form in the free-living organism when deprived of combined nitrogen substrates under aerobic conditions. A multilaminate envelope surrounds the vesicle providing a barrier to direct exposure of the oxygen-labile nitrogenase enzyme that forms within the vesicle. In root nodules, vesicles maymore » or may not form, depending upon the structural configuration of the host plant cells, the ambient oxygen concentration surrounding the root nodule and the expression of host-microbial interactions under the control of the two genomes. Under varying stresses of nutrient availability and the changing gaseous environment, remarkable adaptations may occur in either or both partners of the symbiosis to optimize dinitrogen fixation. 9 refs.« less

  2. Custom-Made Finger Guard to Prevent Wire-Stick Injury to the Operator's Finger while Performing Intermaxillary Fixation.

    PubMed

    Kumaresan, Ramesh; Ponnusami, Karthikeyan; Karthikeyan, Priyadarshini

    2014-12-01

    The treatment of maxillofacial fractures involves different methods from bandages and splinting to methods of open reduction and internal fixation and usually requires control of the dental occlusion with the help of intermaxillary fixation (IMF). Different wiring techniques have been used to aid in IMF including placement of custom-made arch bars, eyelet etc. However, these wiring techniques are with a constant danger of trauma to the surgeon's fingers by their sharp ends. Though there exist a variety of commercially available barrier products and customized techniques to prevent wire-stick injury, cost factor, touch sensitivity, and comfort aspect restrain their acquirement and exploit. This technical note describes the construction of a simple and economical finger guard made of soft thermoplastic material that provides an added protection to fingers from wire-stick type injuries, and its flexible nature permits a comfortable finger flexion movement and acceptable touch sensitivity. This is a simple, economical, reusable puncture, and cut-resistance figure guard by which we can avoid wire-stick type injury to the operator's fingers during wiring technique.

  3. Complications after arthroscopic coracoclavicular reconstruction using a single adjustable-loop-length suspensory fixation device in acute acromioclavicular joint dislocation.

    PubMed

    Shin, Sang-Jin; Kim, Nam-Ki

    2015-05-01

    The purpose of this study was to evaluate clinical and radiological outcomes after arthroscopically assisted coracoclavicular (CC) fixation using a single adjustable-loop-length suspensory fixation device for acute acromioclavicular dislocation and to report intraoperative and postoperative complications. Eighteen consecutive patients with acute acromioclavicular dislocation underwent arthroscopically assisted CC fixation using a single TightRope (Arthrex, Naples, FL). Using the Rockwood classification, 3 patients had grade III dislocations, one patient had a grade IV dislocation, and 14 patients had grade V dislocations. The preoperative CC distance of the injured shoulder was 16.1 ± 2.7 mm (range, 11.2 to 21.0 mm), and it increased by 99% ± 36% (range, 17% to 153%) on average compared with the contralateral shoulder. The average CC distance was 10.5 ± 2.5 mm (range, 7.7 to 15.5 mm), and it increased by 30% ± 30% (range, -9.4% to 90%) at the final follow-up. Compared with immediate postoperative radiographs, the CC distance was maintained in 12 patients, increased between 50% and 100% in 4 patients, and increased more than 100% in 2 patients at final follow-up. However, there was no statistical difference in Constant scores between 6 patients with reduction loss (95.6 ± 4.5) and 12 patients with reduction maintenance (98.4 ± 2.5; P = .17). Perioperative complications occurred in 8 patients, including one case of acromioclavicular arthritis, one case of delayed distal clavicular fracture at the clavicular hole of the device, 3 cases of clavicular or coracoid button failures, and 3 cases of clavicular bony erosion. Satisfactory clinical outcomes were obtained after CC fixation using the single adjustable-loop-length suspensory fixation device for acute acromioclavicular joint dislocation. However, CC fixation failure of greater than 50% of the unaffected side in radiological examinations occurred in 33% of the patients within 3 months after the operation. Additionally, 8 patients (44%) had complications associated with the adjustable-loop-length suspensory fixation device and surgical technical problems. Despite acceptable shoulder function restoration, adequate care should be exercised in surgical treatment of acute acromioclavicular dislocation with a single adjustable-loop-length suspensory fixation device for optimal radiological outcomes. Level IV, therapeutic case series. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  4. [The Effect of Intraoperative Screw Monitoring (Root Monitoring) with the INS-1 System (NUVASIVE) on the Radiological Outcome of Dorsal Instrumentation of the Lumbar Spine].

    PubMed

    Bernhardt, G; Awiszus, F; Meister, U; Heyde, C E; Böhm, H

    2016-06-01

    Transpedicular screw fixation of spinal segments has been described for a variety of surgical indications and is a key element in spinal surgery. The aim of transpedicular screw fixation is to achieve maximal stability. Screw malposition should be obviated to avoid neurological complications. There are published methods of applying evoked EMG to control screw position in relation to neural structures. These studies demonstrated that an intact bony pedicle wall acts as an electrical isolator between the screw and spinal nerve root. The aim of our study was to evaluate the impact of intraoperative pedicle screw monitoring on screw positioning. We enrolled 22 patients in this prospective randomised study, who underwent spinal instrumentation after being split into two equal groups. In the first group, dorsal instrumentation was supplemented with intraoperative nerve root monitoring using the INS-1-System (NuVasive, San Diego USA). In the second group, screws were inserted without additional pedicle monitoring. All patients underwent monosegmental instrumentation with "free hand implanted" pedicle screws. 44 screws were inserted in each group. The screw position was evaluated postoperatively using CT scans. The position of the screws in relation to the pedicle was measured in three different planes: sagittal, axial and coronal. The accuracy of the screw position was described using the Berlemann classification system. Screw position is classified in three groups: type 1 correct screw position, type 2 encroachment on the inner cortical wall, type 3 pedicle cortical perforation. Screw angulation and secondary operative criteria were also evaluated. The use of neuromonitoring did not influence the distance between the centre of the screws and the pedicle wall. Distances only depended on the implantation side (right and left) and the height of implantation (caudal or cranial screw). Because of the low number of cases, no conclusion could be reached about the influence of root monitoring on the correct positioning of the screws. There was at least a non-significant trend towards more frequent perforation of the pedicle in the monitor group. In the present study, we showed that root monitoring had a significant effect on the scattering of transversal angles. These were increased compared to the control group. Otherwise, the implantation angle was not shown to depend on the use of neuromonitoring. Neuromonitoring did not influence blood loss or operative time. The data did not permit any conclusion as to whether this technique can minimise the frequency of pedicle screw malposition. The four coronal plane distances did not depend on the use of neuromonitoring. The inclination angle was also unaffected by neuromonitoring. The only parameter for which we found any effect was the transverse angle. The mean values were similar in both groups, but the variances were not equal. The effect of monitoring on the only parameter which could not be evaluated by fluoroscopy is thus rather unfavourable. Georg Thieme Verlag KG Stuttgart · New York.

  5. The influence of microgravity on Euglena gracilis as studied on Shenzhou 8.

    PubMed

    Nasir, A; Strauch, S M; Becker, I; Sperling, A; Schuster, M; Richter, P R; Weißkopf, M; Ntefidou, M; Daiker, V; An, Y A; Li, X Y; Liu, Y D; Lebert, M

    2014-01-01

    The German Aerospace Center (DLR) enabled German participation in the joint space campaign on the unmanned Shenzhou 8 spacecraft in November 2011. In this report, the effect of microgravity on Euglena gracilis cells is described. Custom-made dual compartment cell fixation units (containing cells in one chamber and fixative - RNA lysis buffer - in another one) were enclosed in a small container and placed in the Simbox incubator, which is an experiment support system. Cells were fixed by injecting them with fixative at different time intervals. In addition to stationary experiment slots, Simbox provides a 1 g reference centrifuge. Cell fixation units were mounted in microgravity and 1 g reference positions of Simbox. Two Simbox incubators were used, one for space flight and the other as ground reference. Cells were fixed soon after launch and shortly before return of the spaceship. Due to technical problems, only early in-flight samples (about 40 min after launch microgravity and corresponding 1 g reference) were fully mixed with fixative, therefore only data from those samples are presented. Transcription of several genes involved in signal transduction, oxidative stress defence, cell cycle regulation and heat shock responses was investigated with quantitative PCR. The data indicate that Euglena cells suffer stress upon short-term exposure to microgravity; various stress-induced genes were up-regulated. Of 32 tested genes, 18 were up-regulated, one down-regulated and the rest remained unaltered. These findings are in a good agreement with results from other research groups using other organisms. © 2013 German Botanical Society and The Royal Botanical Society of the Netherlands.

  6. Clavicle Malunions: Surgical Treatment and Outcome-a Literature Review.

    PubMed

    Sidler-Maier, Claudia Christine; Dedy, Nicolas J; Schemitsch, Emil H; McKee, Michael D

    2018-02-01

    Successful treatment of clavicle malunion represents a major challenge for orthopedic surgeons. The aim of this study was to provide an overview of surgical options for the treatment of clavicle malunions regarding their technical details and clinical results. A comprehensive search of the literature was performed to retrieve articles and conference abstracts regarding the surgical treatment of clavicle malunions. A total of 1873 records were identified and 29 studies were included in the present review, with a total of 103 patients. The majority of the patients (77/103) were treated with an osteotomy and subsequent open reduction internal fixation (ORIF). The next most frequent management choice was debridement, excision, or removal of excess callus or bone ( n  = 19), but other techniques like resection of the clavicle ( n  = 5) or nerve exploration and decompression ( n  = 2) were also reported. The preferred method of fixation was plate fixation ( n  = 53) followed by pin fixation ( n  = 6). The complication rate was low, reported in less than 6% of patients. All of the currently reported surgical techniques to manage symptomatic clavicle malunion have resulted in good clinical outcomes with a low complication rate. Considering biomechanical aspects, correction osteotomy followed by plate fixation seems to be the preferred method. Further studies are needed to compare the various surgical techniques and their specific outcomes in a prospective manner. Nevertheless, this review article can be used as an overview to help choose an optimal operative treatment for patients presenting with a clavicle malunion.

  7. Management of simple (types A and B) closed tibial shaft fractures using percutaneous lag-screw fixation and Ilizarov external fixation in adults.

    PubMed

    El-Sayed, Mohamed; Atef, Ashraf

    2012-10-01

    Although intramedullary fixation of closed simple (type A or B) diaphyseal tibial fractures in adults is well tolerated by patients, providing lower morbidity rates and better mobility, it is associated with some complications. This study evaluated the results of managing these fractures using percutaneous minimal internal fixation using one or more lag screws, and Ilizarov external fixation. This method was tested to evaluate its efficacy in immediate weight bearing, fracture healing and prevention of any post-immobilisation stiffness of the ankle and knee joints. This randomised blinded study was performed at a referral, academically supervised, level III trauma centre. Three hundred and twenty-four of the initial 351 patients completed this study and were followed up for a minimum of 12 (12-88) months. Patient ages ranged from 20 to 51 years, with a mean of 39 years. Ankle and knee movements and full weight bearing were encouraged immediately postoperatively. Solid union was assessed clinically and radiographically. Active and passive ankle and knee ranges of motion were measured and compared with the normal side using the Wilcoxon signed rank test for matched pairs. Subjective Olerud and Molander Ankle Score was used to detect any ankle joint symptoms at the final follow-up. No patient showed delayed or nonunion. All fractures healed within 95-129 days. Based on final clinical and radiographic outcomes, this technique proves to be adequate for managing simple diaphyseal tibial fractures. On the other hand, it is relatively expensive, technically demanding, necessitates exposure to radiation and patients are expected to be frame friendly.

  8. The "in situ molding technique: " an accurate and simple way to fix resorbable plates to the facial skeleton.

    PubMed

    Sadigh, Parviz Lionel; Chang, Li-Ren; Feng, Kuan-Ming; Jeng, Seng-Feng

    2014-09-01

    Bioabsorbable plates developed for use in the facial skeleton have become an integral part of the craniomaxillofacial surgeon's reconstructive armamentarium. They avoid the problems associated with the retention of metal plates and can be easily contoured when heated in a thermobath. The technical process of molding and securing these devices, often through small access incisions, to achieve rigid fixation of facial fractures can be difficult. In this article, we describe a simple, novel technique that we have developed, using hot water suction irrigation, to achieve in situ molding of resorbable plates during facial fracture fixation. We used this technique to fix 123 facial fractures in 110 patients over a 4-year period. No complications secondary to the use of hot water suction irrigation were encountered.

  9. Phrenic nerve neurotization utilizing the spinal accessory nerve: technical note with potential application in patients with high cervical quadriplegia.

    PubMed

    Tubbs, R Shane; Pearson, Blake; Loukas, Marios; Shokouhi, Ghaffar; Shoja, Mohammadali M; Oakes, W Jerry

    2008-11-01

    High cervical quadriplegia is associated with high morbidity and mortality. Artificial respiration in these patients carries significant long-term risks such as infection, atelectasis, and respiratory failure. As phrenic nerve pacing has been proven to free many of these patients from ventilatory dependency, we hypothesized that neurotization of the phrenic nerve with the spinal accessory nerve (SAN) may offer one potential alternative to phrenic nerve stimulation via pacing and may be more efficacious and longer lasting without the complications of an implantable device. Ten cadavers (20 sides) underwent exposure of the cervical phrenic nerve and the SAN in the posterior cervical triangle. The SAN was split into anterior and posterior halves and the anterior half transposed to the ipsilateral phrenic nerve as it crossed the anterior scalene muscle. The mean distance between the cervical phrenic nerve and the SAN in the posterior cervical triangle was 2.5 cm proximally, 4 cm at a midpoint, and 6 cm distally. The range for these measurements was 2 to 4 cm, 3.5 to 5 cm, and 4 to 8.5 cm, respectively. The mean excess length of SAN available after transposition to the more anteromedially placed phrenic nerve was 5 cm (range 4 to 6.5 cm). The mean diameter of these regional parts of the spinal accessory and phrenic nerves was 2 and 2.5 mm, respectively. No statistically significant difference was found for measurements between sides. To our knowledge, using the SAN for neurotization to the phrenic nerve for potential use in patients with spinal cord injury has not been previously explored. Following clinical trials, these data may provide a mechanism for self stimulation of the diaphragm and obviate phrenic nerve pacing in patients with high cervical quadriplegia. Our study found that such a maneuver is technically feasible in the cadaver.

  10. Obstructive hydrocephalus secondary to odontoid pannus: case report and review of literature.

    PubMed

    Soon, Wai Cheong; Thanabalasundaram, Gopiga; Thant, Kyaw Zayar; Ogbonnaya, Ebere Sunny; Harrisson, Stuart Edward

    2018-04-01

    Odontoid pannus or periodontoid pseudotumour is associated with a variety of rheumatological conditions. We report a case of an 80-year old man who presented with acute hydrocephalus following an emergency operation to amputate his infected left big toe. Imaging revealed a large tissue mass causing severe compression at the cervico-medullary junction and obstruction of CSF flow. The acute hydrocephalus was presumed to be related to neck manoeuvring during general anaesthesia. Following an initial emergency CSF diversion through external ventricular drainage catheter insertion, the patient subsequently underwent ventriculo-peritoneal insertion and posterior spinal decompression and fixation. To our knowledge, there have been no reported cases of tophaceous gout of the odontoid pannus causing acute hydrocephalus.

  11. Coronal deformity correction in adolescent idiopathic scoliosis patients using the fulcrum-bending radiograph: a prospective comparative analysis of the proximal thoracic, main thoracic, and thoracolumbar/lumbar curves.

    PubMed

    Li, Jingfeng; Dumonski, Mark L; Samartzis, Dino; Hong, Joseph; He, Shisheng; Zhu, Xiaodong; Wang, Chuanfeng; Vaccaro, Alexander R; Albert, Todd J; Li, Ming

    2011-01-01

    The aim of the prospective, comparative radiographic analysis was to determine the role of the fulcrum-bending radiograph (FBR) for the assessment of the proximal thoracic (PT), main thoracic (MT), and the thoracolumbar/lumbar (TL/L) curves in patients undergoing posterior spinal pedicle screw fixation and fusion for adolescent idiopathic scoliosis (AIS). The FBR demonstrated statistically better correction than other preoperative methods for the assessment of frontal plane correction of the MT curves. The fulcrum-bending correction index (FBCI) has been considered a superior method than the correction rate for comparing curve correction undergoing posterior spinal fusion because it accounts for the curve flexibility. However, their applicability to assess the PT and TL/L curves in AIS patients remains speculative. The relation between FBR and correction obtained by pedicle screws fixation is still unknown. Thirty-eight consecutive AIS patients who underwent pedicle screw fixation and posterior fusion were included in this study. The assessment of preoperative radiographs included standing posterior-anterior (PA), FBR, supine side-bending, and postoperative standing PA and lateral plain radiographs. The flexibility of the curve, as well as the FBCI, was calculated for all patients. Postoperatively, radiographs were assessed at immediate (i.e. 1 week), 3-month, 6-month, 12-month, and 2-year follow-up. Cobb angles were obtained from the PT, MT, and TL/L curves. The study consisted of 9 PT, 37 MT, and 12 TL/L curves, with a mean age of 15.1 years. The mean FBR flexibility of the PT, MT, and the TL/L curves was 42.6, 61.1, and 66.2%, respectively. The mean operative correction rates in the PT, MT, and TL/L curves were 43.4, 69.3, and 73.9%, respectively, and the mean FBCI was 103.8, 117.0, and 114.8%, respectively. Fulcrum-bending flexibility was positively correlated with the operative correction rate in PT, MT, and TL/L curves. Although the correction rate in MT and TL/L curves was higher than PT curves, the FBCI in PT, MT, and TL/L curves was not significantly different (p < 0.05). The FBR can be used to assist in the assessment of PT, MT, and TL/L curve corrections in AIS patients. When curve flexibility is taken into account by FBR, the ability of pedicle screws to correct PT, MT, and TL/L curves is the same.

  12. Treatment of spinal tuberculosis with ultrashort-course chemotherapy in conjunction with partial excision of pathologic vertebrae.

    PubMed

    Wang, Zili; Ge, Zhaohui; Jin, Weidong; Qiao, Yongdong; Ding, Huiqiang; Zhao, Haoning; Lin, Zhikai; Chen, Jun; Yang, Weiyu

    2007-01-01

    The ultrashort-course chemotherapeutical scheme of less than 6 months has been used for part of patients with pulmonary tuberculosis and satisfactory curative effects have already been achieved. However, few systematic and clinical reports so far about medical treatment of spinal tuberculosis by using ultrashort-course chemotherapeutical schemes have been published in the spine-care literature. To assess the results of ultrashort-course chemotherapy (UCC) in conjunction with partial excision of pathological vertebrae for spinal tuberculosis. This is a retrospective comparative study of case series from a single center. Seventy-six cases of spinal tuberculosis, treated during 1998 and 2003 by senior author, were reviewed. All the cases underwent chemotherapies in conjunction with the uniform partial excision of pathological vertebra and had a minimum follow-up of 2 years. Clinical manifestations, laboratory tests, imaging examination, examination by ultrasonic wave B, drug complications, and clinical effects based on the previously described evaluative measures. Of the 76 cases, 28 had UCC with the scheme of 2SHRZ/2.5H(2)R(2)Z(2), 23 had short-course chemotherapy (SCC) with the scheme of 3SHRZ/5H(2)R(2)Z(2), and 25 had standard chemotherapy (SC) with the scheme of 3SHRZ/9H(2)R(2)Z(2). All the patients had anterior partial excisions of pathological vertebrae, large iliac strut graft, and anterior or posterior fixation. The mean time of follow-up surveys for the ultrashort-course, short-course, and standard chemotherapy cases was 42.3 m, 46.5 m, and 55.4 m, respectively. The observance indices included 1) clinical manifestations: disappearance of tuberculosis symptoms, no CC pains, recovery of normal life or work, no percussion pains on pathologic sites, and recovery of neural functions; 2) laboratory tests: normal or close to normal test results of both erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP) or one of them; 3) imaging examinations: X-ray films, computed tomography scan, and magnetic resonance imaging examinations show disappearance of abscesses, no new destructive foci, bone union on the bone grafting interface, satisfactory correction of deformities, and less than 5 degrees of the angle loss of deformity corrections; 4) examination by ultrasonic wave B: no opaque dark area of fluid sonolucent areas identified in possible sites of paravertebral abscesses or gravitation abscesses; and 5) drug complications: hepatic and renal functions, nervus vestibularis lesion, and gastrointestinal tract reactions. All the cases met the protetrakis indices and obtained complete clinical cure of spinal tuberculosis in the last follow-up. The significant differences of major drug complications were found among the 3 groups, with 5 cases of UCC (18%), 15 cases of SCC (65%), and 19 cases of SC (76%). The lasting chemotherapeutic lesion of liver, kidney, or the permanent nervus vestibularis lesion were found 3 cases in SCC, 5 cases in SC, and no case in UCC group. No significant differences in clinical cure rate were found among 3 groups. UCC in conjunction with anterior partial excisions of pathological vertebrae, large iliac strut graft, and anterior or posterior internal instrumental fixation achieved excellent clinical results and the lowest complication rate of antituberculosis chemotherapy.

  13. Spine segmentation from C-arm CT data sets: application to region-of-interest volumes for spinal interventions

    NASA Astrophysics Data System (ADS)

    Buerger, C.; Lorenz, C.; Babic, D.; Hoppenbrouwers, J.; Homan, R.; Nachabe, R.; Racadio, J. M.; Grass, M.

    2017-03-01

    Spinal fusion is a common procedure to stabilize the spinal column by fixating parts of the spine. In such procedures, metal screws are inserted through the patients back into a vertebra, and the screws of adjacent vertebrae are connected by metal rods to generate a fixed bridge. In these procedures, 3D image guidance for intervention planning and outcome control is required. Here, for anatomical guidance, an automated approach for vertebra segmentation from C-arm CT images of the spine is introduced and evaluated. As a prerequisite, 3D C-arm CT images are acquired covering the vertebrae of interest. An automatic model-based segmentation approach is applied to delineate the outline of the vertebrae of interest. The segmentation approach is based on 24 partial models of the cervical, thoracic and lumbar vertebrae which aggregate information about (i) the basic shape itself, (ii) trained features for image based adaptation, and (iii) potential shape variations. Since the volume data sets generated by the C-arm system are limited to a certain region of the spine the target vertebra and hence initial model position is assigned interactively. The approach was trained and tested on 21 human cadaver scans. A 3-fold cross validation to ground truth annotations yields overall mean segmentation errors of 0.5 mm for T1 to 1.1 mm for C6. The results are promising and show potential to support the clinician in pedicle screw path and rod planning to allow accurate and reproducible insertions.

  14. Five-year durability of stand-alone interspinous process decompression for lumbar spinal stenosis

    PubMed Central

    Nunley, Pierce D; Patel, Vikas V; Orndorff, Douglas G; Lavelle, William F; Block, Jon E; Geisler, Fred H

    2017-01-01

    Background Lumbar spinal stenosis is the most common indication for spine surgery in older adults. Interspinous process decompression (IPD) using a stand-alone spacer that functions as an extension blocker offers a minimally invasive treatment option for intermittent neurogenic claudication associated with spinal stenosis. Methods This study evaluated the 5-year clinical outcomes for IPD (Superion®) from a randomized controlled US Food and Drug Administration (FDA) noninferiority trial. Outcomes included Zurich Claudication Questionnaire (ZCQ) symptom severity (ss), physical function (pf), and patient satisfaction (ps) subdomains, leg and back pain visual analog scale (VAS), and Oswestry Disability Index (ODI). Results At 5 years, 84% of patients (74 of 88) demonstrated clinical success on at least two of three ZCQ domains. Individual ZCQ domain success rates were 75% (66 of 88), 81% (71 of 88), and 90% (79 of 88) for ZCQss, ZCQpf, and ZCQps, respectively. Leg and back pain success rates were 80% (68 of 85) and 65% (55 of 85), respectively, and the success rate for ODI was 65% (57 of 88). Percentage improvements over baseline were 42%, 39%, 75%, 66%, and 58% for ZCQss, ZCQpf, leg and back pain VAS, and ODI, respectively (all P<0.001). Within-group effect sizes were classified as very large for four of five clinical outcomes (ie, >1.0; all P<0.0001). Seventy-five percent of IPD patients were free from reoperation, revision, or supplemental fixation at their index level at 5 years. Conclusion After 5 years of follow-up, IPD with a stand-alone spacer provides sustained clinical benefit. PMID:28919727

  15. Five-year durability of stand-alone interspinous process decompression for lumbar spinal stenosis.

    PubMed

    Nunley, Pierce D; Patel, Vikas V; Orndorff, Douglas G; Lavelle, William F; Block, Jon E; Geisler, Fred H

    2017-01-01

    Lumbar spinal stenosis is the most common indication for spine surgery in older adults. Interspinous process decompression (IPD) using a stand-alone spacer that functions as an extension blocker offers a minimally invasive treatment option for intermittent neurogenic claudication associated with spinal stenosis. This study evaluated the 5-year clinical outcomes for IPD (Superion ® ) from a randomized controlled US Food and Drug Administration (FDA) noninferiority trial. Outcomes included Zurich Claudication Questionnaire (ZCQ) symptom severity (ss), physical function (pf), and patient satisfaction (ps) subdomains, leg and back pain visual analog scale (VAS), and Oswestry Disability Index (ODI). At 5 years, 84% of patients (74 of 88) demonstrated clinical success on at least two of three ZCQ domains. Individual ZCQ domain success rates were 75% (66 of 88), 81% (71 of 88), and 90% (79 of 88) for ZCQss, ZCQpf, and ZCQps, respectively. Leg and back pain success rates were 80% (68 of 85) and 65% (55 of 85), respectively, and the success rate for ODI was 65% (57 of 88). Percentage improvements over baseline were 42%, 39%, 75%, 66%, and 58% for ZCQss, ZCQpf, leg and back pain VAS, and ODI, respectively (all P <0.001). Within-group effect sizes were classified as very large for four of five clinical outcomes (ie, >1.0; all P <0.0001). Seventy-five percent of IPD patients were free from reoperation, revision, or supplemental fixation at their index level at 5 years. After 5 years of follow-up, IPD with a stand-alone spacer provides sustained clinical benefit.

  16. Long-bone fractures in persons with spinal cord injury.

    PubMed

    Frotzler, A; Cheikh-Sarraf, B; Pourtehrani, M; Krebs, J; Lippuner, K

    2015-09-01

    Retrospective data analysis. To document fracture characteristics, management and related complications in individuals with traumatic spinal cord injury (SCI). Rehabilitation centre for SCI individuals. Patients' records were reviewed. Patients with traumatic SCI and extremity fractures that had occurred after SCI were included. Patient characteristics, fractured bone, fracture localisation, severity and management (operative/conservative), and fracture-related complications were extracted. A total of 156 long-bone fractures in 107 SCI patients (34 women and 73 men) were identified. The majority of patients were paraplegics (77.6%) and classified as American Spinal Injury Association Impairment Scale A (86.0%). Only the lower extremities were affected, whereby the femur (60.9% of all fractures) was fractured more frequently than the lower leg (39.1%). A total of 70 patients (65.4%) had one fracture, whereas 37 patients (34.6%) had two or more fractures. Simple or extraarticular fractures were most common (75.0%). Overall, 130 (83.3%) fractures were managed operatively. Approximately half of the femur fractures (48.2%) were treated with locking compression plates. In the lower leg, fractures were mainly managed with external fixation (48.8%). Conservative fracture management was applied in 16.7% of the cases and consisted of braces or a well-padded soft cast. Fracture-associated complications were present in 13.5% of the cases but did not differ significantly between operative (13.1%) and conservative (15.4%) fracture management. SCI was associated with simple or extraarticular fractures of the distal femur and the lower leg. Fractures were mainly managed operatively with a low complication rate.

  17. Results of cement augmentation and curettage in aneurysmal bone cyst of spine

    PubMed Central

    Basu, Saumyajit; Patel, Dharmesh R; Dhakal, Gaurav; Sarangi, T

    2016-01-01

    Aneurysmal bone cyst (ABC) is a vascular tumor of the spine. Management of spinal ABC still remains controversial because of its location, vascular nature and incidence of recurrence. In this manuscript, we hereby describe two cases of ABC spine treated by curettage, vertebral cement augmentation for control of bleeding and internal stabilization with two years followup. To the best of our knowledge, this is the first case report in the literature describing the role of cement augmentation in spinal ABC in controlling vascular bleeding in curettage of ABC of spine. Case 1: A 22 year old male patient presented with chronic back pain. On radiological investigation, there were multiple, osteolytic septite lesions at L3 vertebral body without neural compression or instability. Percutaneous transpedicular biopsy of L3 from involved pedicle was done. This was followed by cement augmentation through the uninvolved pedicle. Next, transpedicular complete curettage was done through involved pedicle. Case 2: A 15-year-old female presented with nonradiating back pain and progressive myelopathy. On radiological investigation, there was an osteolytic lesion at D9. At surgery, decompression, pedicle screw-rod fixation and posterolateral fusion from D7 to D11 was done. At D9 level, through normal pedicle cement augmentation was added to provide anterior column support and to control the expected bleeding following curettage. Transpedicular complete curettage was done through the involved pedicle with controlled bleeding at the surgical field. Cement augmentation was providing controlled bleeding at surgical field during curettage, internal stabilization and control of pain. On 2 years followup, pain was relieved and there was a stable spinal segment with well filled cement without any sign of recurrence in computed tomography scan. In selected cases of spinal ABC with single vertebral, single pedicle involvement; cement augmentation of vertebra through normal pedicle has an important role in surgery aimed for curettage of vertebra. PMID:26955184

  18. Dose perturbation effect of metallic spinal implants in proton beam therapy.

    PubMed

    Jia, Yingcui; Zhao, Li; Cheng, Chee-Wai; McDonald, Mark W; Das, Indra J

    2015-09-08

    The purpose of this study was to investigate the effect of dose perturbations for two metallic spinal screw implants in proton beam therapy in the perpendicular and parallel beam geometry. A 5.5 mm (diameter) by 45 mm (length) stainless steel (SS) screw and a 5.5 mm by 35 mm titanium (Ti) screw commonly used for spinal fixation were CT-scanned in a hybrid phantom of water and solid water. The CT data were processed with an orthopedic metal artifact reduction (O-MAR) algorithm. Treatment plans were generated for each metal screw with a proton beam oriented, first parallel and then perpendicular, to the longitudinal axis of the screw. The calculated dose profiles were compared with measured results from a plane-parallel ion chamber and Gafchromic EBT2 films. For the perpendicular setup, the measured dose immediately downstream from the screw exhibited dose enhancement up to 12% for SS and 8% for Ti, respectively, but such dose perturbation was not observed outside the lateral edges of the screws. The TPS showed 5% and 2% dose reductions immediately at the interface for the SS nd Ti screws, respectively, and up to 9% dose enhancements within 1 cm outside of the lateral edges of the screws. The measured dose enhancement was only observed within 5 mm from the interface along the beam path. At deeper depths, the lateral dose profiles appeared to be similar between the measurement and TPS, with dose reduction in the screw shadow region and dose enhancement within 1-2 cm outside of the lateral edges of the metals. For the parallel setup, no significant dose perturbation was detected at lateral distance beyond 3 mm away from both screws. Significant dose discrepancies exist between TPS calculations and ion chamber and film measurements in close proximity of high-Z inhomogeneities. The observed dose enhancement effect with proton therapy is not correctly modeled by TPS. An extra measure of caution should be taken when evaluating dosimetry with spinal metallic implants.

  19. Retrospective exploration of risk factors for L5 radiculopathy following lumbar floating fusion surgery.

    PubMed

    Orita, Sumihisa; Yamagata, Masatsune; Ikeda, Yoshikazu; Nakajima, Fumitake; Aoki, Yasuchika; Nakamura, Junichi; Takahashi, Kazuhisa; Suzuki, Takane; Ohtori, Seiji

    2015-10-17

    Lumbar floating fusion occasionally causes postoperative adjacent segment disorder (ASD) at lumbosacral level, causing L5 spinal nerve disorder by L5-S1 foraminal stenosis. The disorder is considered to be one of the major outcomes of L5-S1 ASD, which has not been evaluated yet. The present study aimed to evaluate the incidence and risk factors of postoperative L5 spinal nerve disorder after lumbar interbody fusion extending to the L5 vertebra. We evaluated 125 patients with a diagnosis of spondylolisthesis who underwent floating fusion surgery with transforaminal lumbar interbody fusion with average postoperative period of 25.2 months. The patients were regarded as symptomatic with postoperative L5 spinal nerve disorder such as radicular pain/numbness in the lower limbs and/or motor dysfunction. We estimated and compared the wedging angle (frontal view) and height (lateral view) of the lumbosacral junction in pre- and postoperative plain X-ray images and the foraminal ratio (ratio of the narrower foraminal diameter to the wider diameter in the craniocaudal direction) in the preoperative magnetic resonance image. Risk factors for the incidence of L5 spinal nerve disorder were explored using multivariate logistic regression. Eight of the 125 patients (6.4%) were categorized as symptomatic, an average of 13.3 months after surgery. The wedging angle was significantly higher, and the foraminal ratio was significantly decreased in the symptomatic group (both P < 0.05) compared to the asymptomatic group. Multivariate logistic regression analysis of possible risk factors revealed that the wedging angle, foraminal ratio, and multileveled fusion were statistically significant. Higher wedging angle and lower foraminal ratio in the lumbosacral junction were significantly predictive for the incidence of L5 nerve root disorder as well as multiple-leveled fusion. These findings indicate that lumbosacral fixation should be considered for patients with these risk factors even if they have few symptoms from the L5-S1 junction.

  20. Dural ectasia in a child with Larsen syndrome.

    PubMed

    Jain, Viral V; Anadio, Jennifer M; Chan, Gilbert; Sturm, Peter F; Crawford, Alvin H

    2014-01-01

    We present a case of an incidental finding of dural ectasia in a child diagnosed with Larsen syndrome. Larsen syndrome is a rare inherited disorder of connective tissue characterized by facial dysmorphism, congenital joint dislocations of the hips, knees and elbows, and deformities of the hands and feet. Dural ectasia is as an abnormal expansion of the dural sac surrounding the spinal cord and may result in spinal morphologic changes, instability, and spontaneous dislocation. To the best of our knowledge, the presence of dural ectasia in Larsen syndrome has not previously been reported. A 6-year-old boy diagnosed with Larsen syndrome presented with an upper thoracic curve measuring 74 degrees, a right thoracic curve measuring 65 degrees, and significant cervicothoracic kyphosis with 50% anterior subluxation of C6 on C7 and C7 on T1. Advanced imaging studies showed dural ectasia (evidenced by spinal canal and dural sac expansion), thinning of pedicles and lamina, and C4 and C6 pars defects with cervical foramen enlargement. The patient received growing rod instrumentation (attached to cervical spine fixation) by a combined anterior/posterior surgical approach using intraoperative halo. Complications included intraoperative medial breach (fully resolved), wound dehiscence, 2 instances of bilateral broken rods, and a broken cervical rod. Following 7 lengthening procedures, the patient underwent definitive fusion. Surgeons should be aware of the potential for dural ectasia in patients with Larsen syndrome. Its presence will cause difficulties in the surgical intervention for spinal deformity. Multiple factors must be considered, and surgical approach and technique will require modification to avoid complications. Although dural ectasia confounds surgical intervention in these patients, surgery still appears to outweigh the risks associated with delayed intervention. The presence of dural ectasia should not preclude surgical decompression and stabilization. This report adds to the body of knowledge on the treatment of Larsen syndrome by demonstrating the potential existence of dural ectasia and highlights the importance of careful and thorough preoperative evaluation and diagnostic imaging.

  1. Spinal Implant Density and Postoperative Lumbar Lordosis as Predictors for the Development of Proximal Junctional Kyphosis in Adult Spinal Deformity.

    PubMed

    McClendon, Jamal; Smith, Timothy R; Sugrue, Patrick A; Thompson, Sara E; O'Shaughnessy, Brian A; Koski, Tyler R

    2016-11-01

    To evaluate spinal implant density and proximal junctional kyphosis (PJK) in adult spinal deformity (ASD). Consecutive patients with ASD receiving ≥5 level fusions were retrospectively analyzed between 2007 and 2010. ASD, elective fusions, minimum 2-year follow-up. age <18 years, neuromuscular or congenital scoliosis, cervical or cervicothoracic fusions, nonelective conditions (infection, tumor, trauma). Instrumented fusions were classified by the Scoliosis Research Society-Schwab ASD classification. Statistical analysis consisted of descriptives (measures of central tendency, dispersion, frequencies), independent Student t tests, χ 2 , analysis of variance, and logistic regression to determine association of implant density [(number of screws + number of hooks)/surgical levels of fusion] and PJK. Mean and median follow-up was 2.8 and 2.7 years, respectively. Eighty-three patients (17 male, 66 female) with a mean age of 59.7 years (standard deviation, 10.3) were analyzed. Mean body mass index (BMI) was 29.5 kg/m 2 (range, 18-56 kg/m 2 ) with mean preoperative Oswestry Disability Index of 48.67 (range, 6-86) and mean preoperative sagittal vertical axis of 8.42. The mean levels fused were 9.95 where 54 surgeries had interbody fusion. PJK prevalence was 21.7%, and pseudoarthrosis was 19.3%. Mean postoperative Oswestry Disability Index was 27.4 (range, 0-74). Independent Student t tests showed that PJK was not significant for age, gender, BMI, rod type, mean postoperative sagittal vertical axis, or Scoliosis Research Society-Schwab ASD classification; but iliac fixation approached significance (P = 0.077). Implant density and postoperative lumbar lordosis (LL) were predictors for PJK (P = 0.018 and 0.045, respectively). Controlling for age, BMI, and gender, postoperative LL (not implant density) continued to show significance in multivariate logistic regression model. PJK, although influenced by a multitude of factors, may be statistically related to implant density and LL. Copyright © 2016. Published by Elsevier Inc.

  2. Posterior fixation including the fractured vertebra for severe unstable thoracolumbar fractures.

    PubMed

    Kanna, Rishi M; Shetty, Ajoy Prasad; Rajasekaran, S

    2015-02-01

    Traditional short-segment fixation of unstable thoracolumbar injuries can be associated with progressive kyphosis and implant failure. Load sharing classification (LSC) recommends supplemental anterior reconstruction for fractures of score 7 or greater. Posterior fixation including the fractured vertebra (PFFV) has biomechanical advantages over conventional short-segment fixation. However, its efficacy in severe thoracolumbar injuries (LSC≥7) has not been studied. To study the clinical, functional, and radiologic results of PFFV for severe, unstable thoracolumbar injuries (LSC≥7) at a minimum of 2 years. A retrospective review of case records. Thirty-two patients with an unstable burst fracture of LSC≥7 treated with PFFV were included. They included clinical outcomes: American Spinal Injury Association grade, visual analog scale (VAS), Oswestry Disability Index (ODI); and radiologic measures: segmental kyphosis angle, vertebral wedge angle, and percentage loss of anterior and posterior vertebral height. Thirty-two patients with LSC≥7 who had undergone PFFV, with a minimum follow-up of 2 years were studied for demographic, injury, and surgical details. Clinical and radiologic outcomes were measured before surgery and at 6, 12, and 24 months postoperatively. The presence of screw breakage, screw pullout, peri-implant loosening, and rod breakage were considered as criteria for implant failure. None of the patients had postoperative implant failure at the final follow-up. The mean preoperative kyphosis angle was 22.9°±7.6°. This improved significantly to 9.2°±6.6° after surgery (p=.000). There was a loss of mean 2.4° (mean kyphosis angle of 11.6°±6.3°) at the final follow-up. The mean preoperative wedge angle was 23.0°±8.1°. This was corrected to 9.7°±6.2° (p=.000). There was a loss of kyphosis (mean 1.2°) in the follow-up period. The mean anterior and posterior vertebral height also showed significant improvements postoperatively, which were maintained at the final follow-up. The mean ODI and VAS scores at the end of 2 years were 17.5% and 1.6, respectively. Reduction of unstable thoracolumbar injuries even with LSC≥7 can be achieved and maintained with the use of short-segment pedicle screw fixation including the fractured vertebra, avoiding the need for anterior reconstruction. In the current era of evolving concepts of fracture fixation, the relevance of LSC in the management of unstable burst fractures is questionable. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. [Comparative study on microplate and anchor fixation in open-door cervical expansive laminoplasty].

    PubMed

    Zeng, Yun; Xiong, Min; Yu, Hualong; He, Ning; Wang, Zhiyong; Liu, Zhigang; Han, Heng; Chen, Sen

    2011-08-01

    To evaluate the effectiveness of microplate fixation in open-door cervical expansive laminoplasty (ELP) by comparing with anchor fixation. Between January 2005 and October 2008, 35 patients with multi-segment cervical spondylotic myelopathy were treated. Of them, 15 patients underwent ELP by microplate fixation (microplate group) and 20 patients underwent ELP by anchor fixation (anchor group). In microplate group, there were 10 males and 5 females with the age of (51.2 +/- 11.5) years; the disease duration ranged from 6 to 60 months (mean, 14 months); and the preoperative Japanese Orthopaedic Association (JOA) score was 7.7 +/- 2.5. In anchor group, there were 13 males and 7 females with the age of (50.7 +/- 10.8) years; the disease duration ranged from 3 to 58 months (mean, 17 months); and the preoperative JOA score was 7.8 +/- 2.9. There was no significant difference in the general data, such as gender, age, and JOA score between 2 groups (P > 0.05). All incisions healed by first intention. Thirty-five cases were followed up 24-68 months (mean, 32 months). The operation time was (113 +/- 24) minutes in anchor group and (111 +/- 27) minutes in microplate group, showing no significant difference (t = 0.231 3, P = 0.818 5). The rate of spinal canal expansion in microplate group (60% +/- 24%) was significantly higher than that in anchor group (40% +/- 18%) (t = 2.820, P = 0.008). The JOA scores of 2 groups at 3 months and 24 months after operation were significantly higher than the preoperative scores (P < 0.01). There was no significant difference in JOA score between 2 groups at 3 months after operation (t = 1.620 5, P = 0.114 6), but the JOA score of microplate group was significantly higher than that of anchor group at 24 months after operation (t = 3.454 3, P = 0.001 5). X-ray film, MRI, and CT scan at 3-6 months after operation displayed that door spindle reached bony fusion. There was no occurrence of "re-close of door" in 2 groups. The rate of complication in microplate group (13.3%, 2/15) was significantly lower than that in anchor group (25.0%, 5/20) (chi2 = 7.160 0, P = 0.008 6). ELP by microplate fixation can achieve the stability quickly after operation, which can help patients to do functional exercises early, and has satisfactory effectiveness and less complications.

  4. Arthroscopic biceps tenodesis: a new technique using bioabsorbable interference screw fixation.

    PubMed

    Boileau, Pascal; Krishnan, Sumant G; Coste, Jean-Sebastien; Walch, Gilles

    2002-01-01

    To report a new technique of arthroscopic biceps tenodesis using bioabsorbable interference screw fixation and the early results. Prospective, nonrandomized study. The principle of arthroscopic biceps tenodesis is simple: after biceps tenotomy, the tendon is exteriorized and doubled on a suture; the biceps tendon is then pulled into a humeral socket (7 or 8 mm x 25 mm) drilled at the top of the bicipital groove, and fixed using a bioabsorbable interference screw (8 or 9 mm x 25 mm) under arthroscopic control. 43 patients treated with this technique between 1997 and 1999 were followed-up for at least 1 year. The technique was indicated in 3 clinical situations: (1) with arthroscopic cuff repair (3 cases), (2) in case of isolated pathology of the biceps tendon with an intact cuff (6 cases), and (3) as an alternative to biceps tenotomy in patients with massive, degenerative and irreparable cuff tears (34 cases). The biceps pathology was tenosynovitis (4 cases), prerupture (15 cases), subluxation (11 cases), and luxation (13 cases). The absolute Constant score improved from 43 points preoperatively to 79 points at review (P <.005). There was no loss of elbow movement and biceps strength was 90% of the strength of the other side. Two patients, operated on early in the series, presented with a rupture of the tenodesis. In both cases the bicipital tendon was very friable and the diameter of the screw proved to be insufficient (7 mm). No neurologic or vascular complications occurred. Arthroscopic biceps tenodesis using bioabsorbable screw fixation is technically possible and gives good clinical results. This technique can be used in cases of isolated pathologic biceps tendon or a cuff tear. A very thin, fragile, almost ruptured biceps tendon is the technical limit of this arthroscopic technique.

  5. The influence of a suction device on fixation of a cemented cup using RSA.

    PubMed

    Timperley, A John; Whitehouse, Sarah L; Hourigan, Patrick G

    2009-03-01

    The quality of technique used at the time of socket cementation is crucial in ensuring a durable long-term result of the implant. We asked whether a new instrument, an aspirator retractor introduced into the wing of the ilium before socket preparation and cementation, would enhance cement fixation as defined by RSA and radiographic examination. We randomized 38 patients into two groups. The surgical technique was identical between the groups with the exception of the use of the aspirator retractor. Patients were followed clinically and with radiostereometry at a minimum of 2 years. We compared gross radiographic appearances, including the depth of penetration of cement and the incidence of postoperative and 2-year radiolucent lines. There was no difference in proximal migration between the two groups. No improvement of fixation was proven from the measured translations and rotations of the socket in the suction group. We found no difference in the number or extent of radiolucent lines or the depth of cement penetration when the iliac suction device was used in conjunction with contemporary cementing techniques. Although the data suggest no short-term advantage in this small study, we will continue to follow these patients presuming there will be improved outcomes in the longer term and since the device provides an easier method of obtaining adequate fixation, especially if technical difficulties are encountered during the pressurization procedure.

  6. Delayed Union of a Sacral Fracture: Percutaneous Navigated Autologous Cancellous Bone Grafting and Screw Fixation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huegli, R. W.; Messmer, P.; Jacob, A. L.

    2003-09-15

    Delayed or non-union of a sacral fracture is a serious clinical condition that may include chronic pain, sitting discomfort, gait disturbances, neurological problems, and inability to work. It is also a difficult reconstruction problem. Late correction of the deformity is technically more demanding than the primary treatment of acute pelvic injuries. Open reduction, internal fixation (ORIF), excision of scar tissue, and bone grafting often in a multi-step approach are considered to be the treatment of choice in delayed unions of the pelvic ring. This procedure implies the risk of neurological and vascular injuries, infection, repeated failure of union, incomplete correctionmore » of the deformity, and incomplete pain relief as the most important complications. We report a new approach for minimally invasive treatment of a delayed union of the sacrum without vertical displacement. A patient who suffered a Malgaigne fracture (Tile C1.3) was initially treated with closed reduction and percutaneous screw fixation (CRPF) of the posterior pelvic ring under CT navigation and plating of the anterior pelvic ring. Three months after surgery he presented with increasing hip pain caused by a delayed union of the sacral fracture. The lesion was successfully treated percutaneously in a single step procedure using CT navigation for drilling of the delayed union, autologous bone grafting, and screw fixation.« less

  7. Fixator-assisted medial tibial plateau elevation to treat severe Blount's disease: outcomes at maturity.

    PubMed

    Fitoussi, F; Ilharreborde, B; Lefevre, Y; Souchet, P; Presedo, A; Mazda, K; Penneçot, G F

    2011-04-01

    Severe forms of Blount's disease may be associated with medial tibial plateau (MTP) depression. Management should then take account of joint congruence, laxity, limb axis, torsional abnomality, leg length discrepancy (LLD) and eventual recurrence history. Eight knees (six patients) were managed in a single step comprising MTP elevation osteotomy, lateral epiphysiodesis and proximal tibia osteotomy to correct varus and rotational deformity. Fixation was achieved using an Ilizarov external fixator. Mean age was 10.5 years. Mean hip-knee-ankle (HKA) angle was 151°; distal femoral varus, 94°; metaphyseal-diaphyseal angle (MDA), 27°; and angle of depression of the medial tibial plateau (ADMTP), 42°. Predicted residual proximal tibial growth was 2.6 cm. At a mean 48 months' follow-up, results were good in six cases, medium in one and poor (due to incomplete lateral epiphysiodesis) in one. Mean lateral tibial torsion was 9° and final LLD 11 mm. Weight-bearing was resumed at 2 months, and the fixator was removed at 5.5 months postoperatively. At end of follow-up, mean HKA angle was 179.6°, MDA 7.3° and ADMTP 5.4°. This technically demanding procedure gave satisfactory results in terms of axes and congruence; longer term assessment remains needed. Level IV. Retrospective study. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  8. Application and Removal of Strippable Coatings via Remote Platform - 13133

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shoffner, P.; Lagos, L.; Maggio, S.

    2013-07-01

    Florida International University's (FIU's) Applied Research Center is currently supporting the Department of Energy (DOE) Environmental Management Office of D and D and Facility Engineering program. FIU is supporting DOE's initiative to improve safety, reduce technical risks, and limit uncertainty within D and D operations by identifying technologies suitable to meet specific facility D and D requirements, assessing the readiness of those technologies for field deployment, and conducting feasibility studies and technology demonstrations of selected technologies and working with technology vendors to optimize the design of their current technologies to accomplish dangerous and demanding tasks during D and D operations.more » To meet one identified technology gap challenge for a technology to remotely apply strippable coatings, fixatives and decontamination gels, FIU identified and performed an initial demonstration of an innovative remote fixative sprayer platform from International Climbing Machines (ICM). The selected technology was demonstrated spraying fixative products at the hot cell mockup facility at the Applied Research Center at FIU in November 2008 under cold (non-radioactive) conditions. The remotely controlled platform was remotely operated and entered the facility and sprayed a fixative onto horizontal and vertical surfaces. Based on the initial FIU demonstration and the specific technical requirements identified at the DOE facilities, a follow-up demonstration was expanded to include strippable coatings and a decontamination gel, which was demonstrated in June 2010 at the ICM facility in Ithaca, NY. This second technology evaluation documented the ability of the remote system to spray the selected products on vertical stainless steel and concrete surfaces to a height of 3 meters (10 feet) and to achieve sufficient coverage and product thickness to promote the ability to peel/remove the strippable coatings and decontamination gel. The next challenge was to determine if a remote platform could be used to remove the strippable coatings and decontamination gels. In 2012, FIU worked with the technology provider, ICM, to conduct feasibility and trade studies to identify the requirements for the remote removal of strippable coatings or decontamination gels using the existing remote controlled platform. (authors)« less

  9. Technical Rebuilding of Movement Function Using Functional Electrical Stimulation

    NASA Astrophysics Data System (ADS)

    Gföhler, Margit

    To rebuild lost movement functions, neuroprostheses based on functional electrical stimulation (FES) artificially activate skeletal muscles in corresponding sequences, using both residual body functions and artificial signals for control. Besides the functional gain, FES training also brings physiological and psychological benefits for spinal cord-injured subjects. In this chapter, current stimulation technology and the main components of FES-based neuroprostheses including enhanced control systems are presented. Technology and application of FES cycling and rowing, both approaches that enable spinal cord-injured subjects to participate in mainstream activities and improve their health and fitness by exercising like able-bodied subjects, are discussed in detail, and an overview of neuroprostheses that aim at restoring movement functions for daily life as walking or grasping is given.

  10. Spinal pedicle subtraction osteotomy for fixed sagittal imbalance patients

    PubMed Central

    Hyun, Seung-Jae; Kim, Yongjung J; Rhim, Seung-Chul

    2013-01-01

    In addressing spinal sagittal imbalance through a posterior approach, the surgeon now may choose from among a variety of osteotomy techniques. Posterior column osteotomies such as the facetectomy or Ponte or Smith-Petersen osteotomy provide the least correction, but can be used at multiple levels with minimal blood loss and a lower operative risk. Pedicle subtraction osteotomies provide nearly 3 times the per-level correction of Ponte/Smith-Petersen osteotomies; however, they carry increased technical demands, longer operative time, and greater blood loss and associated significant morbidity, including neurological injury. The literature focusing on pedicle subtraction osteotomy for fixed sagittal imbalance patients is reviewed. The long-term overall outcomes, surgical tips to reduce the complications and suggestions for their proper application are also provided. PMID:24340276

  11. Neurosurgery: A profession or a technical trade?

    PubMed Central

    Watts, Clark

    2014-01-01

    The American Association of Neurological Surgeons (AANS), 11 years ago converted its Internal Revenue Code (IRC) tax status from a 501 (c) (3) to a 501 (c) (6) entity. By doing so, the professional medical association, now a trade association, was able to more aggressively lobby, support political campaigns, and pursue business opportunities for its members. In the following decade, major changes were seen in the practice of neurosurgery, especially as it relates to spine surgery. With the majority of neurosurgeons limiting themselves to a spine practice, an increased number of spinal procedures, most noted in the Medicare population, was recorded. For example, a 15-fold increase in complex spinal fusions for spinal stenosis was seen between 2002 and 2007. While the basis for this increase was not readily apparent, it was associated with a reduction in reimbursement per case of about 50%, fueling the belief that the increase in complexity of surgery permitted recovery of fees in complex cases to off-set the loss of reimbursement for simpler cases. Considering the growth of spinal surgery within neurosurgery, and decrease funding for spine surgery, in the future there may be too many surgeons chasing too few dollars. There appears to be within neurosurgery a crisis developing where future manpower projections do not realistically match future anticipated specialty funding. PMID:25558426

  12. A five-layer users' need hierarchy of computer input device selection: a contextual observation survey of computer users with cervical spinal injuries (CSI).

    PubMed

    Tsai, Tsai-Hsuan; Nash, Robert J; Tseng, Kevin C

    2009-05-01

    This article presents how the researcher goes about answering the research question, 'how assistive technology impacts computer use among individuals with cervical spinal cord injury?' through an in-depth investigation into the real-life situations among computer operators with cervical spinal cord injuries (CSI). An in-depth survey was carried out to provide an insight into the function abilities and limitation, habitual practice and preference, choices and utilisation of input devices, personal and/or technical assistance, environmental set-up and arrangements and special requirements among 20 experienced computer users with cervical spinal cord injuries. Following the survey findings, a five-layer CSI users' needs hierarchy of input device selection and use was proposed. These needs were ranked in order: beginning with the most basic criterion at the bottom of the pyramid; lower-level criteria must be met before one moves onto the higher level. The users' needs hierarchy for CSI computer users, which had not been applied by previous research work and which has established a rationale for the development of alternative input devices. If an input device achieves the criteria set up in the needs hierarchy, then a good match of person and technology will be achieved.

  13. Functional Characterization of Lamina X Neurons in ex-Vivo Spinal Cord Preparation.

    PubMed

    Krotov, Volodymyr; Tokhtamysh, Anastasia; Kopach, Olga; Dromaretsky, Andrew; Sheremet, Yevhenii; Belan, Pavel; Voitenko, Nana

    2017-01-01

    Functional properties of lamina X neurons in the spinal cord remain unknown despite the established role of this area for somatosensory integration, visceral nociception, autonomic regulation and motoneuron output modulation. Investigations of neuronal functioning in the lamina X have been hampered by technical challenges. Here we introduce an ex-vivo spinal cord preparation with both dorsal and ventral roots still attached for functional studies of the lamina X neurons and their connectivity using an oblique LED illumination for resolved visualization of lamina X neurons in a thick tissue. With the elaborated approach, we demonstrate electrophysiological characteristics of lamina X neurons by their membrane properties, firing pattern discharge and fiber innervation (either afferent or efferent). The tissue preparation has been also probed using Ca 2+ imaging with fluorescent Ca 2+ dyes (membrane-impermeable or -permeable) to demonstrate the depolarization-induced changes in intracellular calcium concentration in lamina X neurons. Finally, we performed visualization of subpopulations of lamina X neurons stained by retrograde labeling with aminostilbamidine dye to identify sympathetic preganglionic and projection neurons in the lamina X. Thus, the elaborated approach provides a reliable tool for investigation of functional properties and connectivity in specific neuronal subpopulations, boosting research of lamina X of the spinal cord.

  14. Comparative analysis of international standards for the fatigue testing of posterior spinal fixation systems.

    PubMed

    Villa, Tomaso; La Barbera, Luigi; Galbusera, Fabio

    2014-04-01

    Preclinical evaluation of the long-term reliability of devices for lumbar fixation is a mandatory activity before they are put into market. The experimental setups are described in two different standards edited by the International Organization for Standardization (ISO) and the American Society for Testing Materials (ASTM), but the evaluation of the suitability of such tests to simulate the actual loading with in vivo situations has never been performed. To calculate through finite element (FE) simulations the stress in the rods of the fixator when subjected to ASTM and ISO standards. To compare the calculated stresses arising in the same fixator once it has been virtually mounted in a physiological environment and loaded with physiological forces and moments. FE simulations and validation experimental tests. FE models of the ISO and ASTM setups were created to conduct simulations of the tests prescribed by standards and calculate stresses in the rods. Validation of the simulations were performed through experimental tests; the same fixator was virtually mounted in an L2-L4 FE model of the lumbar spine and stresses in the rods were calculated when the spine was subjected to physiological forces and moments. The comparison between FE simulations and experimental tests showed good agreement between results obtained using the two methodologies, thus confirming the suitability of the FE method to evaluate stresses in the device in different loading situations. The usage of a physiological load with ASTM standard is impossible due to the extreme severity of the ASTM configuration; in this circumstance, the presence of an anterior support is suggested. Also, ISO prescriptions, although the choice of the setup correctly simulates the mechanical contribution of the discs, seem to overstress the device as compared with a physiological loading condition. Some daily activities, other than walking, can induce a further state of stress in the device that should be taken into account in setting up new experimental procedures. ISO standard loading prescriptions seems to be more severe than the expected physiological ones. The ASTM standard should be completed by including some anterior supporting device and declaring the value of the load to be imposed. Moreover, a further enhancement of standards would be simulating other movements representative of daily activities different from walking. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. One and two level posterior lumbar interbody fusion (PLIF) using an expandable, stand-alone, interbody fusion device: a VariLift® case series

    PubMed Central

    Barrett-Tuck, Rebecca; Del Monaco, Diana

    2017-01-01

    Background Surgical interventions such as posterior lumbar interbody fusion (PLIF) with and without posterior instrumentation are often employed in patients with degenerative spinal conditions that fail to respond to conservative medical management. The VariLift® Interbody Fusion System was developed as a stand-alone solution to provide the benefits of an intervertebral fusion device without the requirement of supplemental pedicle screw fixation. Methods In this retrospective case series, 25 patients underwent PLIF with a stand-alone VariLift® expandable interbody fusion device without adjunctive pedicle screw fixation. There were 12 men and 13 women, with a mean age of 57.2 years (range, 33–83 years); single level in 18 patients, 2 levels in 7 patients. Back pain severity was reported as none, mild, moderate, severe and worst imaginable at baseline, 6 and 12 months. Preoperatively, 88% (22 of 25) of patients reported severe back pain. Results All patients experienced symptomatic improvement and, by 12 months postoperatively, 71% (15 of 21) of patients reported only mild residual pain. Overall, pain scores improved significantly from baseline to 12 months (P=0.0002). There were no revision surgeries and fusion was achieved 12 of 13 patients (92%) who returned for a 12-month radiographic follow-up. There were three cases of intractable postsurgical pain which required extended hospitalization or pain management, one wound infection and one case of surgical site dehiscence, both treated and resolved during inpatient hospitalization. Conclusions In this single-physician case series, the VariLift® device used in single or two-level PLIF provided effective symptom relief and produced a high fusion rate without the need for supplemental fixation. PMID:28435912

  16. One and two level posterior lumbar interbody fusion (PLIF) using an expandable, stand-alone, interbody fusion device: a VariLift® case series.

    PubMed

    Barrett-Tuck, Rebecca; Del Monaco, Diana; Block, Jon E

    2017-03-01

    Surgical interventions such as posterior lumbar interbody fusion (PLIF) with and without posterior instrumentation are often employed in patients with degenerative spinal conditions that fail to respond to conservative medical management. The VariLift ® Interbody Fusion System was developed as a stand-alone solution to provide the benefits of an intervertebral fusion device without the requirement of supplemental pedicle screw fixation. In this retrospective case series, 25 patients underwent PLIF with a stand-alone VariLift ® expandable interbody fusion device without adjunctive pedicle screw fixation. There were 12 men and 13 women, with a mean age of 57.2 years (range, 33-83 years); single level in 18 patients, 2 levels in 7 patients. Back pain severity was reported as none, mild, moderate, severe and worst imaginable at baseline, 6 and 12 months. Preoperatively, 88% (22 of 25) of patients reported severe back pain. All patients experienced symptomatic improvement and, by 12 months postoperatively, 71% (15 of 21) of patients reported only mild residual pain. Overall, pain scores improved significantly from baseline to 12 months (P=0.0002). There were no revision surgeries and fusion was achieved 12 of 13 patients (92%) who returned for a 12-month radiographic follow-up. There were three cases of intractable postsurgical pain which required extended hospitalization or pain management, one wound infection and one case of surgical site dehiscence, both treated and resolved during inpatient hospitalization. In this single-physician case series, the VariLift ® device used in single or two-level PLIF provided effective symptom relief and produced a high fusion rate without the need for supplemental fixation.

  17. Scleral fixation of one piece intraocular lens by injector implantation

    PubMed Central

    Can, Ertuğrul; Başaran, Reşat; Gül, Adem; Birinci, Hakkı

    2014-01-01

    Aim of Study: With an ab-interno technique of transscleral suturing of current one-piece posterior chamber intraocular lenses (PC IOLs) by injector implantation in the absence of capsular support, we aimed to demonstrate the possibility of the implantation of one-piece acrylic PC IOLs that might be produced in the future for only scleral fixation through small clear corneal incision. Materials and Methods: Case report and literature review. Results: This procedure has been performed in eight aphakic eyes with four different types of IOLs. Good centration was achieved with minimal technical effort. All patients had well-centered and stable lenses postoperatively during 9-18 months follow-up. Conclusion: We managed to decrease the risks of surgical trauma and intricate surgical maneuvers requirement. With this technique, excessive fluid leakage and consecutive hypotony can be minimized. PMID:25230961

  18. Generalizable Class Solutions for Treatment Planning of Spinal Stereotactic Body Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weksberg, David C.; Palmer, Matthew B.; Vu, Khoi N.

    2012-11-01

    Purpose: Spinal stereotactic body radiation therapy (SBRT) continues to emerge as an effective therapeutic approach to spinal metastases; however, treatment planning and delivery remain resource intensive at many centers, which may hamper efficient implementation in clinical practice. We sought to develop a generalizable class solution approach for spinal SBRT treatment planning that would allow confidence that a given plan provides optimal target coverage, reduce integral dose, and maximize planning efficiency. Methods and Materials: We examined 91 patients treated with spinal SBRT at our institution. Treatment plans were categorized by lesion location, clinical target volume (CTV) configuration, and dose fractionation scheme,more » and then analyzed to determine the technically achievable dose gradient. A radial cord expansion was subtracted from the CTV to yield a planning CTV (pCTV) construct for plan evaluation. We reviewed the treatment plans with respect to target coverage, dose gradient, integral dose, conformality, and maximum cord dose to select the best plans and develop a set of class solutions. Results: The class solution technique generated plans that maintained target coverage and improved conformality (1.2-fold increase in the 95% van't Riet Conformation Number describing the conformality of a reference dose to the target) while reducing normal tissue integral dose (1.3-fold decrease in the volume receiving 4 Gy (V{sub 4Gy}) and machine output (19% monitor unit (MU) reduction). In trials of planning efficiency, the class solution technique reduced treatment planning time by 30% to 60% and MUs required by {approx}20%: an effect independent of prior planning experience. Conclusions: We have developed a set of class solutions for spinal SBRT that incorporate a pCTV metric for plan evaluation while yielding dosimetrically superior treatment plans with increased planning efficiency. Our technique thus allows for efficient, reproducible, and high-quality spinal SBRT treatment planning.« less

  19. [Team training and assessment in mixed reality-based simulated operating room : Current state of research in the field of simulation in spine surgery exemplified by the ATMEOS project].

    PubMed

    Stefan, P; Pfandler, M; Wucherer, P; Habert, S; Fürmetz, J; Weidert, S; Euler, E; Eck, U; Lazarovici, M; Weigl, M; Navab, N

    2018-04-01

    Surgical simulators are being increasingly used as an attractive alternative to clinical training in addition to conventional animal models and human specimens. Typically, surgical simulation technology is designed for the purpose of teaching technical surgical skills (so-called task trainers). Simulator training in surgery is therefore in general limited to the individual training of the surgeon and disregards the participation of the rest of the surgical team. The objective of the project Assessment and Training of Medical Experts based on Objective Standards (ATMEOS) is to develop an immersive simulated operating room environment that enables the training and assessment of multidisciplinary surgical teams under various conditions. Using a mixed reality approach, a synthetic patient model, real surgical instruments and radiation-free virtual X‑ray imaging are combined into a simulation of spinal surgery. In previous research studies, the concept was evaluated in terms of realism, plausibility and immersiveness. In the current research, assessment measurements for technical and non-technical skills are developed and evaluated. The aim is to observe multidisciplinary surgical teams in the simulated operating room during minimally invasive spinal surgery and objectively assess the performance of the individual team members and the entire team. Moreover, the effectiveness of training methods and surgical techniques or success critical factors, e. g. management of crisis situations, can be captured and objectively assessed in the controlled environment.

  20. Evaluation of some technical factors affecting surgical outcome in photorefractive keratectomy with the VISX 2020 excimer laser

    NASA Astrophysics Data System (ADS)

    Maguen, Ezra I.; Salz, James J.; Papaioannou, Thanassis; Nesburn, Anthony B.

    1995-05-01

    Some technical factors relating to the use of the VISX model 20/20 excimer laser for photorefractive keratectomy will be discussed and the way they affect the final optical correction will be demonstrated, as follows: (1) Discontinuation of nitrogen flow: improved corneal haze but induced a mean undercorrection of 0.8 D, 18 months postoperatively. (2) Discontinuation of the use of the fixation ring did not affect centration in a statistically significant fashion. (3) Enlargement of the optical from 5.0 mm to 6.0 mm zone did not affect the refractive outcome. Visual acuity was improved in eyes which had PRK done with a 6.0 mm optical zone.

  1. Undiagnosed vertebral hemangioma causing a lumbar compression fracture and epidural hematoma in a parturient undergoing vaginal delivery under epidural analgesia: a case report.

    PubMed

    Staikou, Chryssoula; Stamelos, Matthaios; Boutas, Ioannis; Koutoulidis, Vassileios

    2015-08-01

    Vertebral hemangiomas are benign vascular tumours of the bony spine which are usually asymptomatic. Pregnancy-related anatomical and hormonal changes may lead to expansion of hemangiomas and development of neurological symptoms. We present an unusual case of vertebral fracture due to an undiagnosed hemangioma presenting as postpartum back pain following epidural analgesia. A multiparous female with an unremarkable history developed intense lumbar pain after vaginal delivery under epidural analgesia. The pain was attributed to tissue trauma associated with the epidural technique. The patient had no clinical improvement with analgesics, and her symptoms deteriorated over the following days. A magnetic resonance imaging scan revealed an acute fracture of the second lumbar vertebra (L2) with epidural extension and mild compression of the dural sac, suggesting hemangioma as the underlying cause. The patient underwent successful spinal surgery with pedicle screw fixation to stabilize the fracture. Vertebral fractures secondary to acute expansion of a vertebral hemangioma rarely occur during vaginal delivery. In such cases, the labour epidural technique and analgesia may challenge the physician in making the diagnosis. Postpartum severe back pain should be thoroughly investigated even in the absence of neurological deficits, and osseous spinal pathology should be considered in the differential diagnosis.

  2. Medical devices of the head, neck, and spine.

    PubMed

    Hunter, Tim B; Yoshino, Mark T; Dzioba, Robert B; Light, Rick A; Berger, William G

    2004-01-01

    There are many medical devices used for head, neck, and spinal diseases and injuries, and new devices are constantly being introduced. Many of the newest devices are variations on a previous theme. Knowing the specific name of a device is not important. It is important to recognize the presence of a device and to have an understanding of its function as well as to be able to recognize the complications associated with its use. The article discusses the most common and important devices of the head, neck, and spine, including cerebrospinal fluid shunts and the Codman Hakim programmable valve; subdural drainage catheters, subdural electrodes, intracranial electrodes, deep brain stimulators, and cerebellar electrodes; coils, balloons, adhesives, particles, and aneurysm clips; radiation therapy catheters, intracranial balloons for drug installation, and carmustine wafers; hearing aids, cochlear implants, and ossicular reconstruction prostheses; orbital prostheses, intraocular silicone oil, and lacrimal duct stents; anterior and posterior cervical plates, posterior cervical spine wiring, odontoid fracture fixation devices, cervical collars and halo vests; thoracic and lumbar spine implants, anterior and posterior instrumentation for the thoracic and lumbar spine, vertebroplasty, and artificial disks; spinal column stimulators, bone stimulators, intrathecal drug delivery pumps, and sacral stimulators; dental and facial implant devices; gastric and tracheal tubes; vagus nerve stimulators; lumboperitoneal shunts; and temperature- and oxygen-sensing probes. Copyright RSNA, 2004

  3. A novel method of C1-C2 transarticular screw insertion for symptomatic atlantoaxial instability using a customized guiding block: A case report and a technical note.

    PubMed

    Huang, Kuo-Yuan; Lin, Ruey-Mo; Fang, Jing-Jing

    2016-10-01

    Atlantoaxial instability treated with the C1-2 transarticular screw fixation is biomechanically more stable; however, the technique demanding and the potential risk of neurovascular injury create difficulties for clinical usage, and there is still lack of clinical experience till now.We reported an adult female patient with symptomatic atlantoaxial instability due to rheumatoid arthritis that was successfully treated with a bilateral C1-C2 transarticular screw fixation using a customized guiding block. We preoperatively determined the trajectories for bilateral C1-C2 transarticular screws on a 3-dimensional reconstruction model from the computed tomography (CT) and self-developed computer software, and designed a rapid prototyping customized guiding block in order to offer a guide for the entry point and insertion angle of the C1-C2 transarticular screws.The clinical outcome was good, and the follow-up period was >3 years. The accuracy of the screws is good in comparison with preoperative and postoperative CT findings, and no neurovascular injury occurred.The patient was accurately and successfully treated with a bilateral C1-C2 transarticular screw fixation using a customized guiding block.

  4. Iliac screw fixation using computer-assisted computer tomographic image guidance: technical note.

    PubMed

    Shin, John H; Hoh, Daniel J; Kalfas, Iain H

    2012-03-01

    Iliac screw fixation is a powerful tool used by spine surgeons to achieve fusion across the lumbosacral junction for a number of indications, including deformity, tumor, and pseudarthrosis. Complications associated with screw placement are related to blind trajectory selection and excessive soft tissue dissection. To describe the technique of iliac screw fixation using computed tomographic (CT)-based image guidance. Intraoperative registration and verification of anatomic landmarks are performed with the use of a preoperatively acquired CT of the lumbosacral spine. With the navigation probe, the ideal starting point for screw placement is selected while visualizing the intended trajectory and target on a computer screen. Once the starting point is selected and marked with a burr, a drill guide is docked within this point and the navigation probe re-inserted, confirming the trajectory. The probe is then removed and the high-speed drill reinserted within the drill guide. Drilling is performed to a depth measured on the computer screen and a screw is placed. Confirmation of accurate placement of iliac screws can be performed with standard radiographs. CT-guided navigation allows for 3-dimensional visualization of the pelvis and minimizes complications associated with soft-tissue dissection and breach of the ilium during screw placement.

  5. Optimizing Filter-Probe Diffusion Weighting in the Rat Spinal Cord for Human Translation

    PubMed Central

    Budde, Matthew D.; Skinner, Nathan P.; Muftuler, L. Tugan; Schmit, Brian D.; Kurpad, Shekar N.

    2017-01-01

    Diffusion tensor imaging (DTI) is a promising biomarker of spinal cord injury (SCI). In the acute aftermath, DTI in SCI animal models consistently demonstrates high sensitivity and prognostic performance, yet translation of DTI to acute human SCI has been limited. In addition to technical challenges, interpretation of the resulting metrics is ambiguous, with contributions in the acute setting from both axonal injury and edema. Novel diffusion MRI acquisition strategies such as double diffusion encoding (DDE) have recently enabled detection of features not available with DTI or similar methods. In this work, we perform a systematic optimization of DDE using simulations and an in vivo rat model of SCI and subsequently implement the protocol to the healthy human spinal cord. First, two complementary DDE approaches were evaluated using an orientationally invariant or a filter-probe diffusion encoding approach. While the two methods were similar in their ability to detect acute SCI, the filter-probe DDE approach had greater predictive power for functional outcomes. Next, the filter-probe DDE was compared to an analogous single diffusion encoding (SDE) approach, with the results indicating that in the spinal cord, SDE provides similar contrast with improved signal to noise. In the SCI rat model, the filter-probe SDE scheme was coupled with a reduced field of view (rFOV) excitation, and the results demonstrate high quality maps of the spinal cord without contamination from edema and cerebrospinal fluid, thereby providing high sensitivity to injury severity. The optimized protocol was demonstrated in the healthy human spinal cord using the commercially-available diffusion MRI sequence with modifications only to the diffusion encoding directions. Maps of axial diffusivity devoid of CSF partial volume effects were obtained in a clinically feasible imaging time with a straightforward analysis and variability comparable to axial diffusivity derived from DTI. Overall, the results and optimizations describe a protocol that mitigates several difficulties with DTI of the spinal cord. Detection of acute axonal damage in the injured or diseased spinal cord will benefit the optimized filter-probe diffusion MRI protocol outlined here. PMID:29311786

  6. Optimum pelvic incidence minus lumbar lordosis value after operation for patients with adult degenerative scoliosis.

    PubMed

    Sun, Xiang-Yao; Zhang, Xi-Nuo; Hai, Yong

    2017-07-01

    Schwab classification for adult degenerative scoliosis (ADS) concluded that health-related quality of life was closely related to curve type and three sagittal modifiers. It was suggested that pelvic incidence minus lumbar lordosis value (PI-LL) should be corrected within -10°~+10°. However, recent studies also indicated that ideal clinical outcomes could also be achieved in patients without the ideal PI-LL mentioned above. This study evaluated the relation between the clinical outcomes and the PI-LL of Chinese patients with ADS who received long posterior internal fixation and fusion. This was a single-center retrospective comparative study of patients treated by long posterior internal fixation and fusion in our hospital between 2010 and 2014. Inclusion criteria were age >45 years at the time of surgery, Cobb angle of lumbar curves ≥10°, long posterior internal fixation and fusion ≥least 3 motion segments, follow-up ≥2 years, complete preoperative and postoperative radiographic data, and functional evaluation results. Exclusion criteria were history of previous lumbar spine surgery, other kinds of scoliosis, history of severe spinal trauma, spinal tumor, ankylosing spondylitis, and spinal tuberculosis. Seventy-four patients were enrolled in this study. Operative parameters included intraoperative blood loss, duration of surgery, length of hospital stay, number of fusion levels, and decompression. The radiological measurements included Cobb angle of the curves and PI-LL. Clinical outcomes were evaluated by the Japanese Orthopaedic Association score, Oswestry Disability Index (ODI), visual analog scale, and Lumbar Stiffness Disability Index (LSDI). In addition, the complications of surgery were also collected. One-way analysis of variance, Student t test, Kruskal-Wallis test, Pearson chi-square test, and curve estimation were calculated for variables. All the patients were divided into Group 1 (long instrumentation and fusion to L5) and Group 2 (long instrumentation and fusion to S1). Operative parameters, radiological measurements, clinical outcomes, and complications of surgery were compared between two groups to confirm whether distal fusion level could influence therapeutic effect. Then patients were divided into PI-LL<10° (Group A), 10°≤PI-LL≤20° (Group B), PI-LL>20° (Group C). Operative parameters, radiological measurements, clinical outcomes, and complications of surgery were compared between each of the two groups. Curve estimation was performed to evaluate the relationship between postoperative PI-LL and clinical outcomes. No difference was found between Group 1 and Group 2 in all postoperative parameters (p>.05). There were significant differences in final ODI (p<.001) and final LSDI (p<.001) among Group A, Group B, and Group C. Cubic curve model fitted the relationship between PI-LL and final ODI better than other models (R 2 =0.379, p<.001). Cubic curve model fitted the relationship between PI-LL and final LSDI better than other models (R 2 =0.691, p<.001). There was a significant difference in proximal junctional kyphosis (PJK) among groups (p=.038). No significant difference was found in other parameters. Optimal PI-LL value may be achieved between 10° and 20° in Chinese patients with ADS after long posterior instrumentation and fusion surgery with excellent clinical outcomes and a lower PJK occurrence. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. [Carbon fiber-reinforced plastics as implant materials].

    PubMed

    Bader, R; Steinhauser, E; Rechl, H; Siebels, W; Mittelmeier, W; Gradinger, R

    2003-01-01

    Carbon fiber-reinforced plastics have been used clinically as an implant material for different applications for over 20 years.A review of technical basics of the composite materials (carbon fibers and matrix systems), fields of application,advantages (e.g., postoperative visualization without distortion in computed and magnetic resonance tomography), and disadvantages with use as an implant material is given. The question of the biocompatibility of carbon fiber-reinforced plastics is discussed on the basis of experimental and clinical studies. Selected implant systems made of carbon composite materials for treatments in orthopedic surgery such as joint replacement, tumor surgery, and spinal operations are presented and assessed. Present applications for carbon fiber reinforced plastics are seen in the field of spinal surgery, both as cages for interbody fusion and vertebral body replacement.

  8. Five-level sub-axial cervical vertebrectomy and reconstruction: technical report.

    PubMed

    Reig, Adam; Parker, Scott L; McGirt, Matthew J

    2014-05-01

    Regardless of the etiology, severe cervical deformities can be extremely debilitating and are a challenge to correct. Often a multi-modality team approach is required to safely and effectively reduce the deformity, provide adequate decompression, and ensure solid fixation and fusion. In cases of iatrogenic cervical deformity necessitating five-level corpectomy and fixation, the feasibility, safety, and durability of this procedure remains unknown. We describe a patient who presented with debilitating pain and inability to eat due to an iatrogenic chin-on-chest cervical kyphotic deformity. The patient underwent a back-front-back staged procedure requiring five-level cervical vertebrectomy, C3-T1 anterior fixation, and occipital to T5 posterior fusion, resulting in successful reduction of cervical kyphosis from 75 to 0 degrees. At 6 months post-operatively, the patient demonstrated marked improvement in neurologic function and reported substantial improvements in neck pain-specific disability (NDI) and quality of life (SF-12 and EQ-5D). The feasibility and safety of five-level vertebrectomy and reconstruction for chin-on-chest deformity remains poorly described. The current case suggests that thoughtful planning that involves maximizing the patient's health status, judicious use of traction under direct neurological examination, staged circumferential release, and design of a construct that provides anterior and posterior column support with several points of fixation beyond the axis of rotation will attenuate the risk of peri-operative morbidity and potentiate the durability of deformity correction.

  9. Square-lashing technique in segmental spinal instrumentation: a biomechanical study.

    PubMed

    Arlet, Vincent; Draxinger, Kevin; Beckman, Lorne; Steffen, Thomas

    2006-07-01

    Sublaminar wires have been used for many years for segmental spinal instrumentation in scoliosis surgery. More recently, stainless steel wires have been replaced by titanium cables. However, in rigid scoliotic curves, sublaminar wires or simple cables can either brake or pull out. The square-lashing technique was devised to avoid complications such as cable breakage or lamina cutout. The purpose of the study was therefore to test biomechanically the pull out and failure mode of simple sublaminar constructs versus the square-lashing technique. Individual vertebrae were subjected to pullout testing having one of two different constructs (single loop and square lashing) using either monofilament wire or multifilament cables. Four different methods of fixation were therefore tested: single wire construct, square-lashing wiring construct, single cable construct, and square-lashing cable construct. Ultimate failure load and failure mechanism were recorded. For the single wire the construct failed 12/16 times by wire breakage with an average ultimate failure load of 793 N. For the square-lashing wire the construct failed with pedicle fracture in 14/16, one bilateral lamina fracture, and one wire breakage. Ultimate failure load average was 1,239 N For the single cable the construct failed 12/16 times due to cable breakage (average force 1,162 N). 10/12 of these breakages were where the cable looped over the rod. For the square-lashing cable all of these constructs (16/16) failed by fracture of the pedicle with an average ultimate failure load of 1,388 N. The square-lashing construct had a higher pullout strength than the single loop and almost no cutting out from the lamina. The square-lashing technique with cables may therefore represent a new advance in segmental spinal instrumentation.

  10. Subsequent, unplanned spine surgery and life survival of patients operated for neuropathic spine deformity.

    PubMed

    Asher, Marc A; Lai, Sue-Min; Burton, Douglas C

    2012-01-01

    Retrospective study of a prospectively assembled cohort. To characterize the survival from subsequent spine surgery and the life survival of patients treated surgically for severe spinal deformity due to neuropathic diseases. Survivorship analysis is widely used to study the natural history of disease processes and of treatments provided, but has very seldom been used to study patients' course after surgery for spinal deformity associated with neuropathic diseases. Patients with neuropathic spinal deformity treated with primary posterior instrumentation and arthrodesis from 1989 through 2002 were identified and studied by review of charts and radiographs, and by mail survey. Subsequent spine surgery and death events, and the time interval from surgery were identified. Fifteen variables possibly influencing survivorship were studied. There were no perioperative deaths, spinal cord injuries, or acute wound infections in the 117 eligible patients. Reoperation and life survival statuses were available for 110 patients (94%) at an average follow-up of 11.89 years (±5.3; range: 2-20.9 yr). Twelve patients (11%) had subsequent spine surgery. Survival from subsequent spine surgery was 91% at 5 years, 90% at 10 and 15 years, and 72% at 20 years. Proximal fixation problems occurred in 4 patients. Twenty-two patients (20%) had died from 4 to 20 years postoperative. Life survival was 98% at 5 years, 89% at 10 years, 81% at 15 years, and 56% at 20 years. The only variable associated with life survival was the occurrence of one or more perioperative complications, P = 0.0032. The younger half of the series at operation (<13.75 yr) was significantly more likely to have one or more perioperative complications, P = 0.0068. Spinal deformity type and magnitude were similar for the younger and older halves of the patients. Life survival of the patients with cerebral-palsy and not-cerebral-palsy upper motor neuron disease was not different. One-hundred-two of 105 were at least satisfied or would have the surgery again for the same condition. Survival from subsequent spine operation was similar to adolescent idiopathic scoliosis series studied in the same manner. Life survival decline began at 4 years postoperative and was significantly associated with the occurrence of one or more perioperative complications. Even after successful spine deformity surgery, this population's health status is often precarious.

  11. Evolution of the postoperative sagittal spinal profile in early-onset scoliosis: is there a difference between rib-based and spine-based growth-friendly instrumentation?

    PubMed

    Chen, Zhonghui; Li, Song; Qiu, Yong; Zhu, Zezhang; Chen, Xi; Xu, Liang; Sun, Xu

    2017-12-01

    OBJECTIVE Although the vertical expandable prosthetic titanium rib (VEPTR) and growing rod instrumentation (GRI) encourage spinal growth via regular lengthening, they can create different results because of their different fixation patterns and mechanisms in correcting scoliosis. Previous studies have focused comparisons on coronal plane deformity with minimal attention to the sagittal profile. In this retrospective study, the authors aimed to compare the evolution of the sagittal spinal profile in early-onset scoliosis (EOS) treated with VEPTR versus GRI. METHODS The data for 11 patients with VEPTR and 22 with GRI were reviewed. All patients had more than 2 years' follow-up with more than 2 lengthening procedures. Radiographic measurements were performed before and after the index surgery and at the latest follow-up. The complications in both groups were recorded. RESULTS Patients in both groups had similar diagnoses, age at the index surgery, and number of lengthening procedures. The changes in the major coronal Cobb angle and T1-S1 spinal height were not significantly different between the 2 groups. Compared with the GRI group, the VEPTR group had less correction in thoracic kyphosis (23% ± 12% vs 44% ± 16%, p < 0.001) after the index surgery and experienced a greater correction loss in thoracic kyphosis (46% ± 18% vs 11% ± 8%, p < 0.001) at the latest follow-up. Although the increase in the proximal junctional angle was not significantly different (VEPTR: 7° ± 4° vs GRI: 8° ± 5°, p = 0.569), the incidence of proximal junctional kyphosis was relatively lower in the VEPTR group (VEPTR: 18.2% vs GRI: 22.7%). No significant changes in the spinopelvic parameters were observed, while the sagittal vertical axis showed a tendency toward a neutral position in both groups. The overall complication rate was higher in the VEPTR group than in the GRI group (72.7% vs 54.5%). CONCLUSIONS The VEPTR had coronal correction and spinal growth results similar to those with GRI. In the sagittal plane, however, the VEPTR was not comparable to the GRI in controlling thoracic kyphosis. Thus, for hyperkyphotic EOS patients, GRI is recommended over VEPTR.

  12. A clinical evaluation of four non-Luer spinal needle and syringe systems.

    PubMed

    Kinsella, S M; Goswami, A; Laxton, C; Kirkham, L; Wharton, N; Bowen, M

    2012-11-01

    We performed an evaluation of non-Luer spinal devices supplied by four manufacturers or suppliers: Polymedic; Pajunk; Sarstedt; and Smiths. For each supplier, 100 evaluations were performed using a 25-G 90-mm spinal needle, 3-ml syringe, 5-ml syringe and filter needle; for comparison, 100 evaluations were performed with our standard Luer equipment. The non-Luer devices were associated with more qualitative problems compared with the Luer devices, for example, poor feel of dural puncture (9-32% vs 10%, respectively), poor observation of cerebrospinal fluid in the hub (3-27% vs 0%), and connection problem of the syringe to the spinal needle (7-33% vs 0%). There was also more frequent failure to achieve the spinal injection due to equipment-related causes (4-7% vs 0%, respectively). Median (IQR [range]) numeric satisfaction scores for the spinal needles were: Luer 10 (9-10 [7-10]); Polymedic 7 (4-8 [0-10]; Pajunk 7 (5-8 [0-10]); Sarstedt 7 (6-8 [0-10]); and Smiths 9 (7-10 [0-10]) (p<0.0001). Satisfaction scores for all spinal equipment were: Luer 10 (9-10 [5-10]); Polymedic 8 (6-8 [0-10]); Pajunk 7 (5-7 [1-9]); Sarstedt 8 (6-8 [0-10]); and Smiths 8 (8-9 [2-10]) (p<0.0001). Between 21% and 75% of non-Luer evaluations were rated with satisfaction worse than the usual Luer needle compared with 0-10% rated better, depending on the needle type. Between 22% and 76% of non-Luer evaluations were rated with satisfaction worse than the usual Luer equipment compared with 0-14% rated better. Specific concerns included poor feel of tissue planes and observation of cerebrospinal fluid (Polymedic), difficulty with connection of the syringe to the spinal needle and trocar removal (Pajunk), poor feel of tissue planes and needle flexibility (Sarstedt) and difficulty with connection of the syringe to the spinal needle (Smiths). We could not demonstrate a short-term learning curve for the new devices. Decisions on purchasing and implementation of the new non-Luer equipment will have to acknowledge that clinicians may have greater technical problems and reduced satisfaction compared with the current equipment. Anaesthesia © 2012 The Association of Anaesthetists of Great Britain and Ireland.

  13. Cerebrospinal fluid leaks following spinal surgery: use of fat grafts for prevention and repair. Technical note.

    PubMed

    Black, Perry

    2002-03-01

    Cerebrospinal fluid (CSF) leaks are relatively common following spinal surgery. A midline dural tear in the spine is readily repaired by direct application of sutures; however, far-lateral or ventral dural tears are problematic. Fat is an ideal sealant because it is impermeable to water. In this paper the author reports his experience with using fat grafts for the prevention or repair of CSF leaks and proposes a technique in which a large sheet of fat, harvested from the patient's subcutaneous layer, is used to cover not only the dural tear(s) but all of the exposed dura and is tucked into the lateral recess. This procedure prevents CSF from seeping around the fat, which may be tacked to the dura with a few sutures. Fibrin glue is spread on the surface of the fat and is further covered with Surgicel or Gelfoam. For ventral dural tears (associated with procedures in which disc material is excised), fat is packed into the disc space to seal off the ventral dural leak. Dural suture lines following spinal intradural exploration are prophylatically protected from CSF leakage in the same manner. With one exception, 27 dural tears noted during 1650 spinal procedures were successfully repaired using this technique. There was one case of postoperative CSF leakage in 140 cases in which intradural exploration for tumor or other lesions was undertaken. Both postoperative CSF leaks were controlled by applying additional skin sutures. The use of a fat graft is recommended as a rapid, effective means of prevention and repair of CSF leaks following spinal surgery.

  14. Biomechanics of halo-vest and dens screw fixation for type II odontoid fracture.

    PubMed

    Ivancic, Paul C; Beauchman, Naseem N; Mo, Fred; Lawrence, Brandon D

    2009-03-01

    An in vitro biomechanical study of halo-vest and odontoid screw fixation of Type II dens fracture. The objective were to determine upper cervical spine instability due to simulated dens fracture and investigate stability provided by the halo-vest and odontoid screw, applied individually and combined. Previous studies have evaluated posterior fixation techniques for stabilizing dens fracture. No previous biomechanical study has investigated the halo-vest and odontoid screw for stabilizing dens fracture. A biofidelic skull-neck-thorax model was used with 5 osteoligamentous whole cervical spine specimens. Three-dimensional flexibility tests were performed on the specimens while intact, following simulated dens fracture, and following application of the halo-vest alone, odontoid screw alone, and halo-vest and screw combined. Average total neutral zone and total ranges of motion at C0/1 and C1/2 were computed for each experimental condition and statistically compared with physiologic motion limits, obtained from the intact flexibility test. Significance was set at P < 0.05 with a trend toward significance at P < 0.1. Type II dens fracture caused trends toward increased sagittal neutral zone and lateral bending range of motion at C1/2. Spinal motions with the dens screw alone could not be differentiated from physiologic limits. Significant reductions in motion were observed at C0/1 and C1/2 in flexion-extension and axial rotation due to the halo-vest, applied individually or combined with the dens screw. At C1/2, the halo-vest combined with the dens screw generally allowed the smallest average percentages of intact motion: 3% in axial rotation, 17% in flexion-extension, and 18% in lateral bending. The present reduction in C1/2 motion observed, due to the halo-vest and dens screw combined is similar to previously reported immobilization provided by the polyaxial screw/rod system and transarticular screw fixation combined with wiring. The present biomechanical data may be useful to clinicians when choosing an appropriate treatment for those with Type II dens fracture.

  15. Post-operative bracing after pedicle screw fixation for thoracolumbar burst fractures: A cost-effectiveness study.

    PubMed

    Piazza, Matthew; Sinha, Saurabh; Agarwal, Prateek; Mallela, Arka; Nayak, Nikhil; Schuster, James; Stein, Sherman

    2017-11-01

    While frequently prescribed to patients following fixation for spine trauma, the utility of spinal orthoses during the post-operative period is poorly described in the literature. In this study, we calculated rates of reoperation and performed a decision analysis to determine the utility of bracing following pedicle screw fixation for thoracic and lumbar burst fractures. Pubmed was searched for articles published between 2005 and 2015 for terms related to pedicle screw fixation of thoracolumbar fractures. Additionally, a database of neurosurgical patients operated on within the authors institution was also used in the analysis. Incidences of significant adverse events (wound revision for either dehiscence or infection or re-operation for non-union or instability due to hardware failure) were determined. Pooled means and variances of reported parameters were obtained using a random-effects, inverse variance meta-analytic model for observational data. Utilities for surgical outcome and complications were assigned using previously published values. Of the 225 abstracts reviewed, 48 articles were included in the study, yielding a total of 1957 patients. After including patients from the institutional registry, together a total of 2081 patients were included in the final analysis, 1328 of whom were braced. Non-braced patients were older then braced patients, although this only approached significance (p=0.051). Braced patients had significantly lower rates of re-operation for non-union or clinically significant hardware failure (1.3% vs. 1.8%, p<0.001) although the groups had comparable rates of operative wound dehiscence and infection (p=1.000). These two approaches yielded comparable utility scores (p=0.120). Costs between braced and non-braced patients were comparable excluding the cost of the brace (p=0.256); hence, the added cost of the brace suggests that bracing post-operatively is not a cost effective measure. Bracing following operative stabilization of thoracolumbar fracture does not significantly improve stability, nor does it increase wound complications. Moreover, our data suggests that post-operative bracing may not be a cost-effective measure. Copyright © 2017. Published by Elsevier Ltd.

  16. Locked nailing for the treatment of displaced articular fractures of the calcaneus: description of a new procedure with calcanail(®).

    PubMed

    Goldzak, Mario; Mittlmeier, Thomas; Simon, Patrick

    2012-05-01

    Although open reduction and internal fixation is considered the best method for treating displaced articular fractures of the calcaneus, lateral approach is at high risk for wound healing complications. For this reason, the authors developed a posterior approach and a new implant to perform both intrafocal reduction and internal fixation. The aim of this technical note is to describe this method of treatment for displaced articular fractures of the calcaneus, which offered the following advantages: (a) the creation of a working channel that provides also a significant bone autograft, (b) the intrafocal reduction of the displaced articular surface, (c) the insertion of a locking nail that maintains the reduced articular surface at the right height, (d) the possibility to switch from an ORIF to a reconstruction arthrodesis with the same approach and instrumentation in case of severely damaged posterior facet.

  17. Development of a new technique for pedicle screw and Magerl screw insertion using a 3-dimensional image guide.

    PubMed

    Kawaguchi, Yoshiharu; Nakano, Masato; Yasuda, Taketoshi; Seki, Shoji; Hori, Takeshi; Kimura, Tomoatsu

    2012-11-01

    We developed a new technique for cervical pedicle screw and Magerl screw insertion using a 3-dimensional image guide. In posterior cervical spinal fusion surgery, instrumentation with screws is virtually routine. However, malpositioning of screws is not rare. To avoid complications during cervical pedicle screw and Magerl screw insertion, the authors developed a new technique which is a mold shaped to fit the lamina. Cervical pedicle screw fixation and Magerl screw fixation provide good correction of cervical alignment, rigid fixation, and a high fusion rate. However, malpositioning of screws is not a rare occurrence, and thus the insertion of screws has a potential risk of neurovascular injury. It is necessary to determine a safe insertion procedure for these screws. Preoperative computed tomographic (CT) scans of 1-mm slice thickness were obtained of the whole surgical area. The CT data were imported into a computer navigation system. We developed a 3-dimensional full-scale model of the patient's spine using a rapid prototyping technique from the CT data. Molds of the left and right sides at each vertebra were also constructed. One hole (2.0 mm in diameter and 2.0 cm in length) was made in each mold for the insertion of a screw guide. We performed a simulated surgery using the bone model and the mold before operation in all patients. The mold was firmly attached to the surface of the lamina and the guide wire was inserted using the intraoperative image of lateral vertebra. The proper insertion point, direction, and length of the guide were also confirmed both with the model bone and the image intensifier in the operative field. Then, drilling using a cannulated drill and tapping using a cannulated tapping device were carried out. Eleven consecutive patients who underwent posterior spinal fusion surgery using this technique since 2009 are included. The screw positions in the sagittal and axial planes were evaluated by postoperative CT scan to check for malpositioning. The screw insertion was done in the same manner as the simulated surgery. With the aid of this guide the pedicle screws and Magerl screws could be easily inserted even at the level where the pedicle seemed to be very thin and sclerotic on the CT scan. Postoperative CT scan showed that there were no critical breaches of the screws. This method employing the device using a 3-dimensional image guide seems to be easy and safe to use. The technique may improve the safety of pedicle screw and Magerl screw insertion even in difficult cases with narrow sclerotic pedicles.

  18. Tibiotalar joint arthrodesis for the treatment of severe ankle joint degeneration secondary to rheumatoid arthritis.

    PubMed

    Caron, M; Kron, E; Saltrick, K R

    1999-04-01

    The technical aspects of fusion of the rheumatoid ankle do not deviate from those in the post-traumatic or osteoarthritic ankle. Screw fixation can usually be achieved, and rarely is fixation failure a problem in rheumatoid ankle arthrodesis. If fixation is difficult because of deformity or bone quality, external fixation or locking intramedullary nails should be used. The placement of cannulated screws and adequacy of screw fixation has not been a problem (Fig. 13). Screw fixation provides compression and prevents rotation. The surgeon, however, needs to be assured that no screws invade the subtalar joint and that all threads are beyond the arthrodesis site. A washer may be necessary for further stability if this screw is not inserted at too great an angle. The authors have found that troughing out of the cortical surface of the tibia with a power bur aids in screw insertion. Not only does the trough act as a countersink, but it also provides a path for screw insertion and prevents palpable screw irritation. Malalignment is unforgiving. The foot must be placed neutral to dorsiflexion and plantarflexion. Equinus positioning places added stress on the tibia and a back-knee gait occurs. Approximately 5 degrees of valgus is recommended, and varus positioning is unforgiving. Internal and external rotation is determined by the position of the contralateral extremity. Nonunion does not seem to be a problem with rigid internal fixation to any greater degree in patients with RA. Despite this, patients may continue to have pain despite solid fusion, which can be caused by incomplete correction of deformity, painful internal fixation, or adjacent joint pathology. Additionally, patients may experience supramalleolar pain above the fusion site consistent with tibial stress fracture, which is more common if the subtalar or midtarsal joint is rigid or if the patient is obese. A rocker sole shoe with impact-absorbing soles used after brief periods of guarded mobilization in a removable walking cast alleviates this stress on the tibia. Neurovascular insult can be avoided with careful dissection direct to bone, incisions placed in nerve-free zones, and avoidance of plunging deep posteriorly-medially and anteriorly when dissecting and resecting surfaces. Arthrodesis of the tibiotalar joint in the patient with RA should be performed to relieve severe pain caused by advanced arthrosis. Achieving a solid arthrodesis does not seem to be a problem and provides the patient with pain relief; however, marked improvement in patient function and level of activity remains limited by the nature of RA and adjacent joint involvement.

  19. Potential risks of using cement-augmented screws for spinal fusion in patients with low bone quality.

    PubMed

    Martín-Fernández, M; López-Herradón, A; Piñera, A R; Tomé-Bermejo, F; Duart, J M; Vlad, M D; Rodríguez-Arguisjuela, M G; Alvarez-Galovich, L

    2017-08-01

    Dramatic increases in the average life expectancy have led to increases in the variety of degenerative changes and deformities observed in the aging spine. The elderly population can present challenges for spine surgeons, not only because of increased comorbidities, but also because of the quality of their bones. Pedicle screws are the implants used most commonly in spinal surgery for fixation, but their efficacy depends directly on bone quality. Although polymethyl methacrylate (PMMA)-augmented screws represent an alternative for patients with osteoporotic vertebrae, their use has raised some concerns because of the possible association between cement leakages (CLs) and other morbidities. To analyze potential complications related to the use of cement-augmented screws for spinal fusion and to investigate the effectiveness of using these screws in the treatment of patients with low bone quality. A retrospective single-center study. This study included 313 consecutive patients who underwent spinal fusion using a total of 1,780 cement-augmented screws. We analyzed potential complications related to the use of cement-augmented screws, including CL, vascular injury, infection, screw extraction problems, revision surgery, and instrument failure. There are no financial conflicts of interest to report. A total of 1,043 vertebrae were instrumented. Cement leakage was observed in 650 vertebrae (62.3%). There were no major clinical complications related to CL, but two patients (0.6%) had radicular pain related to CL at the S1 foramina. Of the 13 patients (4.1%) who developed deep infections requiring surgical debridement, two with chronic infections had possible spondylitis that required instrument removal. All patients responded well to antibiotic therapy. Revision surgery was performed in 56 patients (17.9%), most of whom had long construction. A total of 180 screws were removed as a result of revision. There were no problems with screw extraction. These results demonstrate the efficacy and safety of cement-augmented screws for the treatment of patients with low bone mineral density. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Durability of renal artery stents in patients with transrenal abdominal aortic endografts.

    PubMed

    Baril, Donald T; Lookstein, Robert A; Jacobs, Tikva S; Won, Jamie; Marin, Michael L

    2007-05-01

    The management of renal artery stenosis in patients with abdominal aortic aneurysms continues to be complex and technically challenging despite advances in endovascular therapy. There is growing concern about the durability of renal artery stents in the setting of transrenal abdominal aortic endografts. This study reports a single-center experience of renal artery stenting with transrenal abdominal aortic endografts for patients with renal artery stenosis. All patients undergoing endovascular abdominal aortic aneurysm repair preceded or followed by renal artery stent placement between January 1999 and December 2005 were retrospectively reviewed from a prospectively gathered endovascular database. Patients were surveyed after renal stent procedures with multidetector computed tomography angiography or duplex sonography. The surveillance data were analyzed for primary patency of the renal artery stent at 6 months, incidence of complications, need for secondary interventions, and changes in creatinine clearance (CrCl). Sixty-two renal artery stents were placed in 56 patients (44 men, 12 women) with a mean age of 77.3 years (range, 61 to 94 years). Forty-one were placed before the endograft procedure, eight were placed during the endograft procedure, and 13 were placed postoperatively. There were no major or minor complications related to the renal artery stent procedures. Transrenal aortic endografts were used in 44 of the 56 patients, and 12 had devices with infrarenal fixation. The mean follow-up was 18.5 months (range, 1 to 73 months). The 6-month primary patency, which could be evaluated for 51 renal artery stents, was 97.4% (37/38) in patients with transrenal fixation and 84.6% (11/13) in patients with infrarenal fixation. The overall rate of in-stent restenosis was 8.5% (4/47) in the transrenal fixation group and 20.0% (3/15) in the infrarenal fixation group. The overall occlusion rate was 2.1% (1/47) in the transrenal fixation group and 0% (0/15) in infrarenal fixation group. Five (83.3%) of six patients underwent successful treatment of in-stent restenosis with placement of a new stent in all five cases. CrCl decreased in the total group by 4.2 +/- 11.8 mL/min, by 4.7 +/- 12.0 mL/min in patients with transrenal fixation, and by 2.2 +/- 11.0 mL/min in patients with infrarenal fixation. The presence of a transrenal aortic endograft did not affect the outcome of the renal artery revascularization procedure in this cohort. Renal artery stenting in the presence of transrenal abdominal aortic endografts appears to be a safe procedure without adverse effect on renal artery stent patency or renal function.

  1. Horizontal and Vertical Stabilization of Acute Unstable Acromioclavicular Joint Injuries Arthroscopy-Assisted

    PubMed Central

    Cisneros, Luis Natera; Sarasquete Reiriz, Juan; Besalduch, Marina; Petrica, Alexandru; Escolà, Ana; Rodriguez, Joaquim; Fallone, Jan Carlo

    2015-01-01

    We describe the technical aspects of an arthroscopy-assisted procedure indicated for the management of acute unstable acromioclavicular joint injuries, consisting of a synthetic augmentation of both the coracoclavicular and acromioclavicular ligaments, that anatomically reproduces the coracoclavicular biomechanics and offers fixation that keeps the torn ends of the ligaments facing one another, thus allowing healing of the native structures without the need for a second surgical procedure for metal hardware removal. PMID:26870653

  2. Extended trochanteric osteotomy: current concepts review.

    PubMed

    Sambandam, Senthil Nathan; Duraisamy, Gopinath; Chandrasekharan, Jayadev; Mounasamy, Varatharaj

    2016-04-01

    Revision total hip arthroplasty is a technically demanding procedure which has gained importance for more than two decades. It was a nightmare for revision surgeons during its initial years of inception before the advent of extended trochanteric osteotomy (ETO). This technique gains access to the femoral medullary canal without compromising the bone stock and aids removal of primary implant and cement mantle without further damaging the parent bone. Like any other surgery, ETO does have certain limitations and complications as reported by various authors. Though it has been routinely used by revision surgeons, thorough knowledge of technical details of ETO is still lacking. So this review article is aimed at addressing the indications, surgical procedure, fixation technique, implant selection and complication of ETO which has been presented over a period of years by various authors. We searched in the most commonly used portals like MEDLINE (PubMed) and Google scholar using appropriate terminologies for the literature regarding the various preoperative, intraoperative and postoperative clinical scenarios in which revision surgeons utilized ETO. ETO is an important tool in the revision surgeon's armamentarium and can be used in variety of clinical scenarios and for various intraoperative needs and goals. Awareness about biomechanics of ETO, indications, implants selection, fixation techniques and complications is paramount for good intraoperative and postoperative outcome. ETO by posterior approach continues to be a work horse approach for most revision surgeons all over the world.

  3. [Endoscopically controlled optimization of trans-scleral suture fixation of posterior chamber lenses in the ciliary sulcus].

    PubMed

    Althaus, C; Sundmacher, R

    1993-08-01

    Two technical difficulties have to be overcome in transscleral suture fixation of posterior chamber intraocular lenses (PCL) in the ciliary sulcus: first, exact needle penetration through the sulcus, and second, exact positioning of the PCL haptics in the sulcus. Incongruence of the two may lead to long-term complications by compression or even strangulation of ciliary processes. Intraocular endoscopy was used intraoperatively to visualize the site of needle penetration and the final location of the haptics in patients. It turned out that with our previously described standard techniques the precision was far less than anticipated. Thus, new technical ways had to be sought to improve the precision of positioning. In secondary implantation without perforating keratoplasty we achieved the best results when the needle was passed ab externo before opening the eye and before anterior vitrectomy, taking advantage of a precisely prepared sclerocorneal zone. Passing the needle ab externo in an already hypotonic eyeball gives much less precise results. In combination with perforating keratoplasty with an open-sky approach, needle penetration ab interno is reliable. Correct positioning of the PCL haptics is at least as difficult as correct needle penetration, a fact which up to now has mostly been ignored. In 33 consecutively operated eyes the technique of implantation and PCL design was varied under endoscopical control.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Successful short-segment instrumentation and fusion for thoracolumbar spine fractures: a consecutive 41/2-year series.

    PubMed

    Parker, J W; Lane, J R; Karaikovic, E E; Gaines, R W

    2000-05-01

    A retrospective review of all the surgically managed spinal fractures at the University of Missouri Medical Center during the 41/2-year period from January 1989 to July 1993 was performed. Of the 51 surgically managed patients, 46 were instrumented by short-segment technique (attachment of one level above the fracture to one level below the fracture). The other 5 patients in this consecutive series had multiple trauma. These patients were included in the review because this was a consecutive series. However, they were grouped separately because they were instrumented by long-segment technique because of their multiple organ system injuries. The choice of the anterior or posterior approach for short-segment instrumentation was based on the Load-Sharing Classification published in a 1994 issue of Spine. The purpose of this review was to demonstrate that grading comminution by use of the Load-Sharing Classification for approach selection and the choice of patients with isolated fractures who are cooperative with spinal bracing for 4 months provide the keys to successful short-segment treatment of isolated spinal fractures. The current literature implies that the use of pedicle screws for short-segment instrumentation of spinal fracture is dangerous and inappropriate because of the high screw fracture rate. Charts, operative notes, preoperative and postoperative radiographs, computed tomography scans, and follow-up records of all patients were reviewed carefully from the time of surgery until final follow-up assessment. The Load-Sharing Classification had been used prospectively for all patients before their surgery to determine the approach for short-segment instrumentation. Denis' Pain Scale and Work Scales were obtained during follow-up evaluation for all patients. All patients were observed over 40 months except for 1 patient who died of unrelated causes after 35 months. The mean follow-up period was 66 months (51/2 years). No patient was lost to follow-up evaluation. Prospective application of the Load-Sharing Classification to the patients' injury and restriction of the short-segment approach to cooperative patients with isolated spinal fractures (excluding multisystem trauma patients) allowed 45 of 46 patients instrumented by the short-segment technique to proceed to successful healing in virtual anatomic alignment. The Load-Sharing Classification is a straightforward way to describe the amount of bony comminution in a spinal fracture. When applied to patients with isolated spine fractures who are cooperative with 3 to 4 months of spinal bracing, it can help the surgeon select short-segment pedicle-screw-based fixation using the posterior approach for less comminuted injuries and the anterior approach for those more comminuted. The choice of which fracture-dislocations should be strut grafted anteriorly and which need only posterior short-segment pedicle-screw-based instrumentation also can be made using the Load-Sharing Classification.

  5. EVALUATION OF SURGICAL TREATMENT OF FRACTURES OF THORACOLUMBAR SPINE WITH THIRD-GENERATION MATERIAL FOR INTERNAL FIXATION

    PubMed Central

    Bortoletto, Adalberto; Rodrigues, Luiz Cláudio Lacerda; Matsumoto, Marcelo Hide

    2015-01-01

    Objective: To evaluate the functional results from patients with surgical fractures in the thoracolumbar spine. Method: A prospective study including 100 patients with spinal fractures in the thoracic and lumbar segments was conducted. The lesions were classified in accordance with the AO system, and the patients were treated surgically. The presence of early kyphosis and its evolution after the surgical intervention, and the presence of postoperative pain and its evolution up to the 24th week after the surgery, were evaluated. We compared our data with the literature. Results: One hundred surgical patients were analyzed, of which 37 were type A, 46 were type B and 17 were Type C. Patients who presented Frankel A kept their clinical status, but patients with Frankel B or higher evolved with some improvement. The average improvement in pain based on a visual analog scale was more than four points. All the patients were able to return to their daily routine activities, although we did not take the return to work to be an assessment criterion. Conclusion: Despite controversy regarding the indications for surgery in cases of fractured spine, we believe that the method that we used was satisfactory because of the good results and low complication rate. However, more randomized prospective studies with longer follow-up are needed in order to evaluate this type of fixation. PMID:27047822

  6. Hybrid Instrumentation in Lumbar Spinal Fusion: A Biomechanical Evaluation of Three Different Instrumentation Techniques.

    PubMed

    Obid, Peter; Danyali, Reza; Kueny, Rebecca; Huber, Gerd; Reichl, Michael; Richter, Alexander; Niemeyer, Thomas; Morlock, Michael; Püschel, Klaus; Übeyli, Hüseyin

    2017-02-01

    Ex vivo human cadaveric study. The development or progression of adjacent segment disease (ASD) after spine stabilization and fusion is a major problem in spine surgery. Apart from optimal balancing of the sagittal profile, dynamic instrumentation is often suggested to prevent or impede ASD. Hybrid instrumentation is used to gain stabilization while allowing motion to avoid hypermobility in the adjacent segment. In this biomechanical study, the effects of two different hybrid instrumentations on human cadaver spines were evaluated and compared with a rigid instrumentation. Eighteen human cadaver spines (T11-L5) were subdivided into three groups: rigid, dynamic, and hook comprising six spines each. Clinical parameters and initial mechanical characteristics were consistent among groups. All specimens received rigid fixation from L3-L5 followed by application of a free bending load of extension and flexion. The range of motion (ROM) for every segment was evaluated. For the rigid group, further rigid fixation from L1-L5 was applied. A dynamic Elaspine system (Spinelab AG, Winterthur, Switzerland) was applied from L1 to L3 for the dynamic group, and the hook group was instrumented with additional laminar hooks at L1-L3. ROM was then evaluated again. There was no significant difference in ROM among the three instrumentation techniques. Based on this data, the intended advantage of a hybrid or dynamic instrumentation might not be achieved.

  7. A biomechanical comparison of 2 technical variations of double-row rotator cuff fixation: the importance of medial row knots.

    PubMed

    Busfield, Benjamin T; Glousman, Ronald E; McGarry, Michelle H; Tibone, James E; Lee, Thay Q

    2008-05-01

    Previous studies have shown comparable biomechanical properties of double-row fixation versus double-row fixation with a knotless lateral row. SutureBridge is a construct that secures the cuff with medial row mattress suture anchors and knotless lateral row fixation of the medial suture ends. Recent completely knotless constructs may lead to lesser clinical outcomes if the construct properties are compromised from lack of suture knots. A completely knotless construct without medial row knots will compromise the biomechanical properties in both cyclic and failure-testing parameters. Controlled laboratory study. Six matched pairs of cadaveric shoulders were randomized to 2 groups of double row fixation with SutureBridge: group 1 with medial row knots, and group 2 without medial row knots. The specimens were placed in a materials test system at 30 degrees of abduction. Cyclic testing to 180 N at 1 mm/sec for 30 cycles was performed, followed by tensile testing to failure at 1 mm/sec. Data included cyclic and failure data from the materials test system and gap data using a video digitizing system. All data from paired specimens were compared using paired Student t tests. Group 1 had a statistically significant difference (P < .05) for gap formation for the 1st (3.47 vs 5.05 mm) and 30th cycle (4.22 vs 8.10 mm) and at yield load (5.2 vs 9.1 mm). In addition, there was a greater energy absorbed (2805 vs 1648 N-mm), yield load (233 vs 183.1 N), and ultimate load (352.9 vs 253.9 N) for group 1. The mode of failure for the majority (4/6) of group 2 was lateral row failure, whereas all group 1 specimens failed at the clamp. Although lateral row knotless fixation has been shown not to sacrifice structural integrity of this construct, the addition of a knotless medial row compromises the construct leading to greater gapping and failure at lower loads. This may raise concerns regarding recently marketed completely knotless double row constructs.

  8. Lateral mass screw-rod fixation of the cervical spine: a prospective clinical series with 1-year follow-up.

    PubMed

    Deen, H Gordon; Birch, Barry D; Wharen, Robert E; Reimer, Ronald

    2003-01-01

    Lateral mass plating has become the technique of choice for posterior cervical fixation. Although these systems are safe and reliable, they can be difficult to use in patients with abnormal cervical anatomy; screw placement can be compromised by the fixed hole spacing of the plate; screw back-out and other forms of implant failure can occur; and extension across the cervicothoracic junction can be problematic. To report a series of patients undergoing posterior cervical stabilization with a polyaxial screw-rod construct and to investigate whether this new system offers any advantages over existing methods of fixation. A prospective study evaluating clinical and radiographic parameters in a consecutive series of patients treated with this technique. There were 21 patients in the study group. The surgical indication was cervical spondylosis in 14, trauma in 2, postsurgical kyphosis in 2 and 1 case each of congenital cervicothoracic stenosis, C7-T1 pseudarthrosis and basilar invagination with brainstem compression. Clinical indicators included age, gender, neurologic status, surgical indication and number of levels stabilized. Note was made of whether laminectomy and concomitant anterior reconstructive surgery were performed. Radiographic indicators included early postoperative computed tomography (CT) scan to check for screw placement and plain radiographs at subsequent visits. The participants in this study underwent posterior cervical stabilization using lateral mass screw-rod fixation. Clinical and radiographic assessment was carried out immediately after surgery, and 3, 6 and 12 months after surgery. One-year follow-up was obtained in all cases. A total of 212 screws were implanted in 21 patients. Fixation was carried out over an average of 5.5 spinal segments (range, 2 to 11). The system was successfully implanted in all patients despite the presence of coronal and sagittal plane deformities and/or lateral mass abnormalities in the majority of cases. This system allowed for screw placement in the occiput, C1 lateral mass, C2 pars, C3-C7 lateral masses and upper thoracic pedicles. Early postoperative CT scanning confirmed satisfactory screw placement in all cases. Three patients experienced transient single-level radiculopathy, for an incidence of 1.4% per screw placed. Two patients developed wound seromas requiring evacuation. There were no infections or other wound healing problems. There were no examples of cord or vertebral artery injury, cerebrospinal fluid leak, screw malposition or back-out, loss of alignment or implant failure. When compared with plating techniques, screw-rod fixation appeared to offer several advantages. First, unlike plates, rods proved to be amenable to multiplanar contouring, which is often needed for deformities associated with cervical spondylosis. Second, lateral mass screw placement was more precise because it was not constrained by the hole spacing of the plate. Third, screw back-out and other types of implant failure were not seen. Fourth, the screw-rod system was more easily extended to the occiput and across the cervicothoracic junction. Fifth, the screw-rod system permitted the application of compression, distraction and reduction forces within the construct, to a greater extent than plate systems. The incidence of postoperative radiculopathy was similar to that seen with plate systems. These data indicate that posterior cervical stabilization with polyaxial screw-rod fixation is a safe, straightforward technique that appears to offer some advantages over existing methods of fixation. Results appear to be durable at 1-year follow-up. Benefits are more significant with longer constructs, especially those extending to the occiput or crossing the cervicothoracic junction.

  9. Heart valve bioprosthesis durability: a challenge to the new generation of porcine valves.

    PubMed

    Valente, M; Minarini, M; Maizza, A F; Bortolotti, U; Thiene, G

    1992-01-01

    Long-term experience with first generation porcine valve xenografts enabled identification of the major limitations to their durability: (1) prosthetic-ventricular mismatch due to the high profile of the stent in patients with mitral stenosis and a small left ventricle; (2) high-pressure fixation with loss of natural collagen crimping in the fibrosa, and wash-out of proteoglycans in the spongiosa; (3) xenograft tissue autolysis, due to the long interval between animal slaughter and aortic valve removal fixation; (4) muscle shelf in the right coronary cusp, which created a gradient and could undergo accelerated calcification and/or spontaneous perforation with time; (5) a flexible polypropylene stent, which could creep or even fracture with consequent inward bending of the stent; (6) progressive time-related dystrophic calcification; (7) host fibrous tissue ingrowth. An awareness of these limitations stimulated technical modifications, which frequently brought about distinct improvements: (1) the reduction of the stent profile eliminated the problem of mismatch, but resulted in a higher tendency towards cusp prolapse and earlier commissural tearing; (2) natural collagen waviness, proteoglycans and cusp extensibility were preserved by employing low or even zero pressure during the fixation process; (3) earlier valve fixation enabled preservation of cell integrity; (4) a new orifice for small valves was designed by replacing the right muscular cusp, thus achieving less gradient and avoiding muscle-shelf-related complications; (5) polypropylene was replaced by Delrin as stent material; (6) calcium-retarding agents like T6 and toluidine blue were applied during commercial processing and storage in order to mitigate tissue mineralization.(ABSTRACT TRUNCATED AT 250 WORDS)

  10. Towards Development of Robotic Aid for Rehabilitation of Locomotion-Impaired Subjects

    NASA Technical Reports Server (NTRS)

    Bejczy, Antal K.

    2000-01-01

    Manual assistance of therapists to help movement of legs of spinal cord injured (SCI) subjects during stepping on a treadmill for locomotion rehabilitation has severe economic and technical limitations. Scientists at the Department of Physiological Science at the University of California Los Angeles (UCLA) and roboticists at the Jet Propulsion Laboratory (JPL) initiated a joint effort to develop a robotic mechanism capable of performing controlled motions equivalent to the arm and hand motions of therapists assisting the stepping of locomotion impaired subjects on a treadmill, while the subjects' body weight is partially supported by an overhead harness. A first necessary technical step towards this development is to measure and understand the kinematics and dynamics of the therapists' arm and hand motions as they are reflected on the subjects' leg movement. This paper describes an initial measurement system developed for this purpose together with the related measurement results, and outlines the planned future technical work.

  11. Spine Stereotactic Body Radiotherapy: Indications, Outcomes, and Points of Caution

    PubMed Central

    Eppinga, Wietse; Charest-Morin, Raphaele; Soliman, Hany; Myrehaug, Sten; Maralani, Pejman Jabehdar; Campbell, Mikki; Lee, Young K.; Fisher, Charles; Fehlings, Michael G.; Chang, Eric L.; Lo, Simon S.; Sahgal, Arjun

    2017-01-01

    Study Design: A broad narrative review. Objectives: The objective of this article is to provide a technical review of spine stereotactic body radiotherapy (SBRT) planning and delivery, indications for treatment, outcomes, complications, and the challenges of response assessment. The surgical approach to spinal metastases is discussed with an overview of emerging minimally invasive techniques. Methods: A comprehensive review of the literature was conducted on the techniques, outcomes, and developments in SBRT and surgery for spinal metastases. Results: The optimal management of patients with spinal metastases is complex and requires multidisciplinary assessment from an oncologic team that is familiar with the shifting paradigm as a consequence of evolving techniques in surgery and stereotactic radiation, as well as new developments in systemic agents. The Spinal Instability Neoplastic Score and the epidural spinal cord compression (Bilsky) grading system are useful tools that facilitate communication among oncologic team members and can direct management by providing a baseline assessment of risks prior to therapy. The combined multimodality approach with “separation surgery” followed by postoperative spine SBRT achieves thecal sac decompression, improves tumor control, and avoids complications that may be associated with more extensive surgery. Conclusion: Spine SBRT is a highly effective treatment that is capable of delivering ablative doses to the target while sparing the critical organs-at-risk, chiefly the critical neural tissues, within a short and manageable schedule. At the same time, surgery occupies an important role in select patients, particularly with the expanding availability and expertise in minimally invasive techniques. With rapid adoption of spine SBRT in centers outside of the academic setting, it is imperative for the practicing oncologist to understand the relevance and application of these evolving concepts. PMID:28507888

  12. Comparison of Maternal and Neonatal Effects of Combined Spinal Epidural Anaesthesia in Either the Sitting or Lateral Position During Elective Cesarean Section

    PubMed Central

    Tan, Ece Dumanlar; Günaydın, Berrin

    2014-01-01

    Objective Our goal was to demonstrate which position would be hemodynamically and technically better by comparing the effects of combined spinal epidural (CSE) in the sitting or lateral decubitus position for elective cesarean deliveries on maternal and neonatal parameters and ephedrine requirement. Methods Sixty parturients were randomly assigned into two groups to perform CSE in the sitting (Group I, n=30) or right lateral decubitus position (Group II, n=30) using hyperbaric 10 mg bupivacaine and 20 μg fentanyl. Mean arterial pressure (MAP), heart rate (HR), and characteristics of sensory and motor block were recorded from intrathecal drug administration until the end of surgery. Ephedrine and 1st analgesic requirement, number of attempts to perform CSE, incidence of paresthesia during spinal needle insertion, and Apgar scores were recorded. Results Ephedrine requirements and HR changes were similar in both groups. However, MAP values at 45 min in Group II were significantly less than in Group I. Maximum sensory block levels in Group II were significantly higher than in Group I. Despite similar motor block recovery times in both groups, regression times of sensory block and 1st analgesic requirement in Group II were significantly longer than in Group I. Incidence of paresthesia due to spinal needle (3.3% versus 20% in Groups I and II, respectively) and number of attempts to perform CSE (26.7% versus 60% in Groups I and II, respectively) were significantly higher in Group II. Apgar scores were similar in both groups. Conclusion Performing CSE in the sitting position would be safer and easier because higher and earlier onset of sensory block, and a greater number attempts at epidural insertion and paresthesia develop to spinal needle insertion in the right lateral position. PMID:27366384

  13. Distribution of glycinergic neuronal somata in the rat spinal cord.

    PubMed

    Hossaini, Mehdi; French, Pim J; Holstege, Jan C

    2007-04-20

    Glycine transporter 2 (GlyT2) mRNA is exclusively expressed in glycinergic neurons, and is presently considered a reliable marker for glycinergic neuronal somata. In this study, we have performed non-radioactive in situ hybridization to localize GlyT2 mRNA in fixed free-floating sections of cervical (C2 and C6), thoracic (T5), lumbar (L2 and L5) and sacral (S1) segments of the rat spinal cord. The results showed that in all segments the majority of the GlyT2 mRNA labeled (glycinergic) neuronal somata was present in the deep dorsal horn and the intermediate zone (laminae III-VIII), with around 50% (range 43.7-70.9%) in laminae VII&VIII. In contrast, the superficial dorsal horn, the motoneuronal cell groups and the area around the central canal contained only few glycinergic neuronal somata. The density (number of glycinergic neuronal somata per mm(2)) was also low in these areas, while the highest densities were found in laminae V to VIII. The lateral spinal nucleus and the lateral cervical nucleus also contained a limited number of glycinergic neurons. Our findings showed that the distribution pattern of the glycinergic neuronal somata is similar in all the examined segments. The few differences that were found in the relative laminar distribution between some of the segments, are most likely due to technical reasons. We therefore conclude that the observed distribution pattern of glycinergic neuronal somata is present throughout the spinal cord. Our findings further showed that the non-radioactive in situ hybridization technique for identifying GlyT2 mRNA in fixed free-floating sections is a highly efficient tool for identifying glycinergic neurons in the spinal cord.

  14. Modified rush pin technique for two- or three-part proximal humeral fractures.

    PubMed

    Mallick, A; Hearth, M; Singh, S; Pandey, R

    2008-12-01

    To report the outcomes of modified Rush pin fixation for proximal humeral fractures. 42 men and 20 women aged 19 to 94 (mean, 64) years with 2- or 3-part proximal humeral fractures underwent reduction and fixation using the modified Rush pin technique. 11 patients died from reasons unrelated to the surgery. Of 40 (out of 51) patients completing a subjective functional assessment using an Oxford Shoulder Questionnaire, 28 (70%) had 2-part and 10 (25%) had 3-part displaced fractures, and the remaining 2 (5%) had fracture-dislocations (one being 2-part and one 3-part). 25 (63%) patients were very satisfied (including one with a 3-part fracture after 6 months of rehabilitation), 7 (17%) were moderately satisfied, and 8 (20%) were not satisfied. There were 8 complications, including pin cut-out from the proximal fragment (n=2), proximal pin migration (n=2), distal pin migration (n=1), cortical perforation during surgery (n=1), mild ulnar nerve symptoms (n=1). No patients had non-union, myositis ossificans, avascular necrosis of the humeral head, or axillary nerve injury. The modified Rush pin fixation minimises tissue dissection; the implants are cheap and readily available; and the technical expertise is easily learnt. This technique is a suitable alternative of fixing proximal humeral fractures, especially in the elderly.

  15. Extraforaminal Lumbar Interbody Fusion at the L5-S1 Level: Technical Considerations and Feasibility.

    PubMed

    Kurzbuch, Arthur Robert; Kaech, Denis; Baranowski, Pawel; Baranowska, Alicja; Recoules-Arche, Didier

    2017-09-01

    Background  Extraforaminal lumbar interbody fusion (ELIF) surgery is a muscle-sparing approach that allows the treatment of various degenerative spinal diseases. It is technical challenging to perform the ELIF approach at the L5-S1 level because the sacral ala obstructs the view of the intervertebral disk space. Methods  We reported earlier on the ELIF technique in which the intervertebral disk is targeted at an angle of 45 degrees relative to the midline. In this article we describe the technical process we developed to overcome the anatomic relation between the sacral ala and the intervertebral disk space L5-S1 that hinders the ELIF approach at this level. We then report in a retrospective analysis on the short-term clinical and radiologic outcome of 100 consecutive patients with degenerative L5-S1 pathologies who underwent ELIF surgery. Results  The L5-S1 ELIF approach could be realized in all patients. The short-term clinical outcome was evaluated 5 months after surgery: 92% of the patients were satisfied with their postoperative result; 8% had a poor result. Overall, 17% of the patients presented light radicular or low back pain not influencing their daily activity, and 82% of the patients working before surgery returned to work 3 to 7 months after surgery. The radiologic outcome was documented by computed tomography at 5 months after surgery and showed fusion in 99% of the patients. Lumbar magnetic resonance imaging performed in 5 patients at 6 months after surgery revealed the integrity of the paraspinal muscles. Conclusions  ELIF surgery at the L5-S1 level is technically feasible for various degenerative spinal diseases. Analysis of the clinical and radiologic data in a consecutive retrospective cohort of patients who underwent this surgical procedure showed a good short-term clinical outcome and fusion rate. Georg Thieme Verlag KG Stuttgart · New York.

  16. Feasibility study of patient-specific surgical templates for the fixation of pedicle screws.

    PubMed

    Salako, F; Aubin, C-E; Fortin, C; Labelle, H

    2002-01-01

    Surgery for scoliosis, as well as other posterior spinal surgeries, frequently uses pedicle screws to fix an instrumentation on the spine. Misplacement of a screw can lead to intra- and post-operative complications. The objective of this study is to design patient-specific surgical templates to guide the drilling operation. From the CT-scan of a vertebra, the optimal drilling direction and limit angles are computed from an inverse projection of the pedicle limits. The first template design uses a surface-to-surface registration method and was constructed in a CAD system by subtracting the vertebra from a rectangular prism and a cylinder with the optimal orientation. This template and the vertebra were built using rapid prototyping. The second design uses a point-to-surface registration method and has 6 adjustable screws to adjust the orientation and length of the drilling support device. A mechanism was designed to hold it in place on the spinal process. A virtual prototype was build with CATIA software. During the operation, the surgeon places either template on patient's vertebra until a perfect match is obtained before drilling. The second design seems better than the first one because it can be reused on different vertebra and is less sensible to registration errors. The next step is to build the second design and make experimental and simulations tests to evaluate the benefits of this template during a scoliosis operation.

  17. Operative management of patients with non-spinal metastatic bone disease. Does it actually improve quality of life?

    PubMed

    Umer, Masood; Mohib, Yasir; Umer, Hafiz

    2014-12-01

    To determine the survival rate and functional outcome of skeletal stabilisation in patients with metastatic bone disease. The retrospective study was conducted at Aga Khan University Hospital, Karachi, and comprised data of patients with non-spinal metastatic bone disease managed surgically from January 2002 to December 2010. All patients had been managed by experienced orthopaedic, oncology and multidisciplinary teams. Patients managed by non-oncologic orthopaedic surgeons were excluded. The prognostic influence of clinical, pathological and treatment variables on Musculoskeletal Tumour Society score, range of motion, local complications and death rate were measured. SPSS 19 was used for statistical analysis. Of the 49 patients whose records were included in the study, 21(42.9%) males and 28(57.1%) females with an overall median age of 59 years. Most common primary tumour site was breast in 15(3.8%) followed by lungs in 11(22.4%), Open reduction and internal fixation was the mpst commonly used procedure in 18(36.7%) patients. Mean duration of follow-up was 30.20±29.2 SD months (range: 10-48 months). The median patient survival was 23 months. 23% patients have superficial surgical site infection. Mean Musculoskeletal Tumour Society score was 23.73±14.3 SD. The results confirm the principle that surgery for metastatic disease is done primarily to improve quality of life and ambulation status, and to alleviate pain.

  18. Basic Study for Ultrasound-Based Navigation for Pedicle Screw Insertion Using Transmission and Backscattered Methods

    PubMed Central

    Chen, Ziqiang; Wu, Bing; Zhai, Xiao; Bai, Yushu; Zhu, Xiaodong; Luo, Beier; Chen, Xiao; Li, Chao; Yang, Mingyuan; Xu, Kailiang; Liu, Chengcheng; Wang, Chuanfeng; Zhao, Yingchuan; Wei, Xianzhao; Chen, Kai; Yang, Wu; Ta, Dean; Li, Ming

    2015-01-01

    The purpose of this study was to understand the acoustic properties of human vertebral cancellous bone and to study the feasibility of ultrasound-based navigation for posterior pedicle screw fixation in spinal fusion surgery. Fourteen human vertebral specimens were disarticulated from seven un-embalmed cadavers (four males, three females, 73.14 ± 9.87 years, two specimens from each cadaver). Seven specimens were used to measure the transmission, including tests of attenuation and phase velocity, while the other seven specimens were used for backscattered measurements to inspect the depth of penetration and A-Mode signals. Five pairs of unfocused broadband ultrasonic transducers were used for the detection, with center frequencies of 0.5 MHz, 1 MHz, 1.5 MHz, 2.25 MHz, and 3.5 MHz. As a result, good and stable results were documented. With increased frequency, the attenuation increased (P<0.05), stability of the speed of sound improved (P<0.05), and penetration distance decreased (P>0.05). At about 0.6 cm away from the cortical bone, warning signals were easily observed from the backscattered measurements. In conclusion, the ultrasonic system proved to be an effective, moveable, and real-time imaging navigation system. However, how ultrasonic navigation will benefit pedicle screw insertion in spinal surgery needs to be determined. Therefore, ultrasound-guided pedicle screw implantation is theoretically effective and promising. PMID:25861053

  19. Sudden onset odontoid fracture caused by cervical instability in hypotonic cerebral palsy.

    PubMed

    Shiohama, Tadashi; Fujii, Katsunori; Kitazawa, Katsuhiko; Takahashi, Akiko; Maemoto, Tatsuo; Honda, Akihito

    2013-11-01

    Fractures of the upper cervical spine rarely occur but carry a high rate of mortality and neurological disabilities in children. Although odontoid fractures are commonly caused by high-impact injuries, cerebral palsy children with cervical instability have a risk of developing spinal fractures even from mild trauma. We herein present the first case of an odontoid fracture in a 4-year-old boy with cerebral palsy. He exhibited prominent cervical instability due to hypotonic cerebral palsy from infancy. He suddenly developed acute respiratory failure, which subsequently required mechanical ventilation. Neuroimaging clearly revealed a type-III odontoid fracture accompanied by anterior displacement with compression of the cervical spinal cord. Bone mineral density was prominently decreased probably due to his long-term bedridden status and poor nutritional condition. We subsequently performed posterior internal fixation surgically using an onlay bone graft, resulting in a dramatic improvement in his respiratory failure. To our knowledge, this is the first report of an odontoid fracture caused by cervical instability in hypotonic cerebral palsy. Since cervical instability and decreased bone mineral density are frequently associated with cerebral palsy, odontoid fractures should be cautiously examined in cases of sudden onset respiratory failure and aggravated weakness, especially in hypotonic cerebral palsy patients. Copyright © 2012 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  20. Indocyanine green videoangiography "in negative": definition and usefulness in spinal dural arteriovenous fistulae.

    PubMed

    Simal Julián, Juan Antonio; Miranda Lloret, Pablo; López González, Antonio; Evangelista Zamora, Rocío; Botella Asunción, Carlos

    2013-05-01

    Indocyanine green videoangiography (IGV) has proven its effectiveness in the field of exovascular neurosurgery, both in the intracranial and spinal compartment, but is necessary to define a systematic process for the performance of the IGV to facilitate its interpretation during the procedure. We have defined and applied the concept of videoangiography "in negative" (INIGV) to spinal dural arteriovenous fistulae (dAVF) for the detection and treatment of arteriovenous shunts, so called because the first phase is performed with the vessel suggestive of being pathological occluded. A Pentero-operating microscope with near-infrared IGV-integrated system (Carl Zeiss Co., Germany) was used. At our institution, 24 patients were treated for a spinal dAVF between 1995 and 2011, only in the last 4 cases, INIGV was performed. We describe the IGV in negative procedure and show the most illustrative cases. In all cases, the fistula occlusion was confirmed by postoperative selective digital subtraction angiography (DSA). INIGV demonstrate its capacity in detecting vessels not actually arterialized that should be respected and avoid some of the main limitations of the conventional IGV. This is a technical description about an Indocyanine green (ICG) videoangiographic procedure modification that is superior to merely performing ICG before and after clipping of a dAVF. The INIGV results are rapid and easy to interpret procedure and provide great advantages to the dAVF treatment. Nevertheless, further studies are needed with a larger sample size to determine if INIGV may reduce the need to perform immediate postoperative DSA.

  1. A simple method to ensure proper screw position and plate size selection using the Morscher cervical spine locking plate. Technical note.

    PubMed

    Ball, P A; Benzel, E C; Baldwin, N G

    1994-04-01

    The use of bone plate instrumentation with screw fixation has proved to be a useful adjunctive measure in anterior cervical spine fusion surgery. Proper fitting, positioning, and attachment of this instrumentation have been shown to be frequently suboptimal if done without radiographic guidance. The most commonly used method of radiographic assistance for placement of this instrumentation is fluoroscopy. While this gives satisfactory technical results, it is expensive and time-consuming, and exposes the patient and the operating room personnel to ionizing radiation. The authors present a simple technique to ensure screw placement and plate fitting using Kirschner wires and a single lateral radiograph. This technique saves time, reduces exposure to radiation, and has led to satisfactory results in over 20 operative cases.

  2. Fabrication of polycaprolactone-silanated β-tricalcium phosphate-heparan sulfate scaffolds for spinal fusion applications.

    PubMed

    Bhakta, Gajadhar; Ekaputra, Andrew K; Rai, Bina; Abbah, Sunny A; Tan, Tuan Chun; Le, Bach Quang; Chatterjea, Anindita; Hu, Tao; Lin, Tingxuan; Arafat, M Tarik; van Wijnen, Andre J; Goh, James; Nurcombe, Victor; Bhakoo, Kishore; Birch, William; Xu, Li; Gibson, Ian; Wong, Hee-Kit; Cool, Simon M

    2018-05-01

    Interbody spinal fusion relies on the use of external fixation and the placement of a fusion cage filled with graft materials (scaffolds) without regard for their mechanical performance. Stability at the fusion site is instead reliant on fixation hardware combined with a selected cage. Ideally, scaffolds placed into the cage should both support the formation of new bone and contribute to the mechanical stability at the fusion site. We recently developed a scaffold consisting of silane-modified PCL-TCP (PCL-siTCP) with mechanical properties that can withstand the higher loads generated in the spine. To ensure the scaffold more closely mimicked the bone matrix, we incorporated collagen (Col) and a heparan sulfate glycosaminoglycan sugar (HS3) with increased affinity for heparin-binding proteins such as bone morphogenetic protein-2 (BMP-2). The osteostimulatory characteristic of this novel device delivering exogenous BMP2 was assessed in vitro and in vivo as a prelude to future spinal fusion studies with this device. A combination of cell-free assays (BMP2 release), progenitor cell-based assays (BMP2 bioactivity, cell proliferation and differentiation), and rodent ectopic bone formation assays was used to assess the osteostimulatory characteristics of the PCL-siTCP-based scaffolds. Freshly prepared rat mesenchymal stem cells were used to determine reparative cell proliferation and differentiation on the PCL-siTCP-based scaffolds over a 28-day period in vitro. The bioactivity of BMP2 released from the scaffolds was assessed on progenitor cells over a 28-day period using ALP activity assays and release kinetics as determined by enzyme-linked immunosorbent assay. For ectopic bone formation, intramuscular placement of scaffolds into Sprague Dawley rats (female, 4 weeks old, 120-150 g) was achieved in five animals, each receiving four treatments randomized for location along the limb. The four groups tested were (1) PCL-siTCP/Col (5-mm diameter×1-mm thickness), PCL-siTCP/Col/BMP2 (5 µg), (3) PCL-siTCP/Col/HS3 (25 µg), and (4) PCL-siTCP/Col/HS3/BMP2 (25 and 5 µg, respectively). Bone formation was evaluated at 8 weeks post implantation by microcomputed tomography (µCT) and histology. Progenitor cell-based assays (proliferation, mRNA transcripts, and ALP activity) confirmed that BMP2 released from PCL-siTCP/Col/HS3 scaffolds increased ALP expression and mRNA levels of the osteogenic biomarkers Runx2, Col1a2, ALP, and bone gla protein-osteocalcin compared with devices without HS3. When the PCL-siTCP/Col/HS3/BMP2 scaffolds were implanted into rat hamstring muscle, increased bone formation (as determined by two-dimensional and three-dimensional µCTs and histologic analyses) was observed compared with scaffolds lacking BMP2. More consistent increases in the amount of ectopic bone were observed for the PCL-siTCP/Col/HS3/BMP2 implants compared with PCL-siTCP/Col/BMP2. Also, increased mineralizing tissue within the pores of the scaffold was seen with modified-tetrachrome histology, a result confirmed by µCT, and a modest but detectable increase in both the number and the thickness of ectopic bone structures were observed with the PCL-siTCP/Col/HS3/BMP2 implants. The combination of PCL-siTCP/Col/HS3/BMP2 thus represents a promising avenue for further development as a bone graft alternative for spinal fusion surgery. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Anterior lumbar fusion with titanium threaded and mesh interbody cages.

    PubMed

    Rauzzino, M J; Shaffrey, C I; Nockels, R P; Wiggins, G C; Rock, J; Wagner, J

    1999-12-15

    The authors report their experience with 42 patients in whom anterior lumbar fusion was performed using titanium cages as a versatile adjunct to treat a wide variety of spinal deformity and pathological conditions. These conditions included congenital, degenerative, iatrogenic, infectious, traumatic, and malignant disorders of the thoracolumbar spine. Fusion rates and complications are compared with data previously reported in the literature. Between July 1996 and July 1999 the senior authors (C.I.S., R.P.N., and M.J.R.) treated 42 patients by means of a transabdominal extraperitoneal (13 cases) or an anterolateral extraperitoneal approach (29 cases), 51 vertebral levels were fused using titanium cages packed with autologous bone. All vertebrectomies (27 cases) were reconstructed using a Miami Moss titanium mesh cage and Kaneda instrumentation. Interbody fusion (15 cases) was performed with either the BAK titanium threaded interbody cage (in 13 patients) or a Miami Moss titanium mesh cage (in two patients). The average follow-up period was 14.3 months. Seventeen patients had sustained a thoracolumbar burst fracture, 12 patients presented with degenerative spinal disorders, six with metastatic tumor, four with spinal deformity (one congenital and three iatrogenic), and three patients presented with spinal infections. In five patients anterior lumbar interbody fusion (ALIF) was supplemented with posterior segmental fixation at the time of the initial procedure. Of the 51 vertebral levels treated, solid arthrodesis was achieved in 49, a 96% fusion rate. One case of pseudarthrosis occurred in the group treated with BAK cages; the diagnosis was made based on the patient's continued mechanical back pain after undergoing L4-5 ALIF. The patient was treated with supplemental posterior fixation, and successful fusion occurred uneventfully with resolution of her back pain. In the group in which vertebrectomy was performed there was one case of fusion failure in a patient with metastatic breast cancer who had undergone an L-3 corpectomy with placement of a mesh cage. Although her back pain was immediately resolved, she died of systemic disease 3 months after surgery and before fusion could occur. Complications related to the anterior approach included two vascular injuries (two left common iliac vein lacerations); one injury to the sympathetic plexus; one case of superficial phlebitis; two cases of prolonged ileus (greater than 48 hours postoperatively); one anterior femoral cutaneous nerve palsy; and one superficial wound infection. No deaths were directly related to the surgical procedure. There were no cases of dural laceration and no nerve root injury. There were no cases of deep venous thrombosis, pulmonary embolus, retrograde ejaculation, abdominal hernia, bowel or ureteral injury, or deep wound infection. Fusion-related complications included an iliac crest hematoma and prolonged donor-site pain in one patient. There were no complications related to placement or migration of the cages, but there was one case of screw fracture of the Kaneda device that did not require revision. The authors conclude that anterior lumbar fusion performed using titanium interbody or mesh cages, packed with autologous bone, is an effective, safe method to achieve fusion in a wide variety of pathological conditions of the thoracolumbar spine. The fusion rate of 96% compares favorably with results reported in the literature. The complication rate mirrors the low morbidity rate associated with the anterior approach. A detailed study of clinical outcomes is in progress. Patient selection and strategies for avoiding complication are discussed.

  4. Intraluminal radiation for esophageal cancer: a Howard University technique.

    PubMed

    Moorthy, C R; Nibhanupudy, J R; Ashayeri, E; Goldson, A L; Espinoza, M C; Nidiry, J J; Warner, O G; Roux, V J

    1982-03-01

    The objective of radiotherapeutic management in esophageal cancer is to accomplish maximum tumor sterilization with minimal normal tissue damage. This sincere effort is most often countered by the differential in tumor dose response vs normal tissue tolerance. Intraluminal isotope radiation, with its inherent advantage of rapid dose falloff, spares the lungs, the spinal cord, and other vital structures, yet yields adequately high doses to esophageal tumor. Though in existence since the turn of the century, the method of intracavitary radium bougie application dropped out of favor due to technical difficulties imposed by the size of the radium source and radiation exposure to the personnel involved. The authors describe a simple "iridium 192 afterloading intraluminal technique" that eliminates technical problems and reduces radiation exposure considerably.

  5. Radiographic Analysis of One-level Minimally Invasive Transforaminal Lumbar Interbody Fusion (MI-TLIF) With Unilateral Pedicle Screw Fixation for Lumbar Degenerative Diseases.

    PubMed

    Shen, Xiaolong; Wang, Lei; Zhang, Hailong; Gu, Xin; Gu, Guangfei; He, Shisheng

    2016-02-01

    A prospective randomized study was conducted. The purpose of this study was to assess the radiographic outcomes of one-level minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) with unilateral pedicle screw instrumentation for degenerative lumbar spine disease. MI-TLIF has become an increasingly popular method of lumbar arthrodesis. Recent technological advances in spinal instrumentation have culminated in the development of MI-TLIF with unilateral pedicle screw fixation. However, there are few published studies on radiographic outcomes of the MI-TLIF with unilateral pedicle screw fixation. A total of 65 patients with one-level degenerative lumbar spine disease were enrolled in this study. Patients were randomized into the unilateral or bilateral fixation group based on a computer-generated number list. Thirty-one patients (17 men and 14 women; average age, 57.3 y) were randomized to the unilateral group (group A) and 34 patients (16 men and 18 women; average age, 58.9 y) to the bilateral group (group B). All patients underwent minimally invasive decompression, interbody fusion, and pedicle screw fixation with the assistance of microscopic tubular retractor system (METRx-MD) and Sextant system. All patients were asked to follow-up at 3, 6, and thereafter once every 6 months after surgery. The visual analog scale (VAS), Oswestry disability index (ODI), and modified Prolo (mProlo) scores were obtained for all patients 24 hours before the operation and at each follow-up visit. The whole lumbar lordosis (WL), the segmental lordosis (SL), fusion level disk space angle, lumbar scoliosis angle, and segmental scoliosis angle were determined before and after surgery on standard x-rays. The disk height index (DI) and the lumber curvature index (LI) were also evaluated. The mean follow-up was 26.6 months, with a range of 18-36 months. All patients showed evidence of fusion at 12 months postoperatively. Statistically, there was no significant difference between the 2 groups in terms of demographic data. The average postoperative VAS, ODI, and mProlo scores improved significantly in each group. No significant differences were found between the 2 groups in relation to VAS, ODI, and mProlo scores at each follow-up time point. There were no significant differences between the 2 groups in relation to WL, SL, disk space angle, lumbar scoliosis angle, segmental scoliosis angle, DI, and LI. There was also no difference between postoperative different follow-up visits in terms of these radiographic parameters in both groups. There was a positive linear correlation between the LI and WL in both groups. One-level unilateral pedicle screw instrumented MI-TLIF provided similar radiologic and clinical outcomes to bilateral pedicle screw instrumented MI-TLIF. This study showed that MIS-TLIF with unilateral pedicle screw fixation would be sufficient in the management of preoperatively stable patients with lumbar degenerative disease.

  6. The feasibility of inserting a C1 pedicle screw in patients with ponticulus posticus: a retrospective analysis of eleven patients.

    PubMed

    Zhang, Xin-Liang; Huang, Da-Geng; Wang, Xiao-Dong; Zhu, Jin-Wen; Li, Yi-Bing; He, Bao-Rong; Hao, Ding-Jun

    2017-04-01

    Ponticulus posticus is a common anatomic variation that can be mistaken for a broad posterior arch during C1 pedicle screw placement. When the atlas lateral mass screws are placed via the posterior arch, injury to the vertebral artery may result. To our knowledge, there are few clinical studies that have analyzed the feasibility of C1 pedicle screw fixation in patients with ponticulus posticus, in clinical practice. To evaluate the feasibility of inserting a C1 pedicle screw in patients with ponticulus posticus. Between January 2008 and January 2012, 11 consecutive patients with atlantoaxial instability, and with a ponticulus posticus at C1, underwent posterior fusion surgery in our institution. According to preoperative computed tomography (CT) reconstruction, a complete ponticulus posticus was found unilaterally in nine patients and bilaterally in two. Postoperative CT reconstructive imaging was performed to assess whether C1 pedicle screw placement was successful. Patients were followed up at regular intervals and evaluated for symptoms of ponticulus posticus syndrome. Thirteen C1 pedicles (atlas vertebral artery groove), each with a complete ponticulus posticus, were successfully inserted with thirteen 3.5- or 4.0-mm diameter pedicle screws, without resection of the bony anomaly. No intraoperative complications (venous plexus, vertebral artery, or spinal cord injury) occurred. The mean follow-up period was 21 (range 14-30) months. Postoperative CT reconstructive images showed that all 13 pedicle screws were inserted in the C1 pedicles without destruction of the atlas pedicle cortical bone. In the follow-up period, none of the patients demonstrated clinical symptoms of ponticulus posticus syndrome or developed bone fusion. Three-dimensional CT imaging should be considered prior to C1 pedicle screw fixation in patients with ponticulus posticus, to avoid mistaking the ponticulus posticus for a widened dorsal arch of the atlas. If there is no ponticulus posticus syndrome preoperatively, C1 pedicle screw fixation can be successfully performed without removing the bony anomaly.

  7. Palliative Surgery in Treating Painful Metastases of the Upper Cervical Spine

    PubMed Central

    Wu, Xinghuo; Ye, Zhewei; Pu, Feifei; Chen, Songfeng; Wang, Baichuan; Zhang, Zhicai; Yang, Cao; Yang, Shuhua; Shao, Zengwu

    2016-01-01

    Abstract Increased incidence of upper cervical metastases and higher life expectancy resulted in higher operative rates in patients. The purpose of this study was to explore the methods and the clinical outcomes of palliative surgery for cervical spinal metastases. A systematic review of a 15-case series of upper cervical metastases treated with palliative surgery was performed. All cases underwent palliative surgery, including anterior tumor resection and internal fixation in 3 cases, posterior tumor resection and internal fixation in 10 cases, and combined anterior and posterior tumor resection and internal fixation in 2 cases. Patients were followed-up clinically and radiologically after the operation, and visual analog scale (VAS) and activities of daily living scores were calculated. In addition, a literature review was performed and patients with upper cervical spine metastases were analyzed. The mean follow-up period was 12.5 months (range, 3–26 months) in this consecutive case series. The pain was substantially relieved in 93.3% (14/15) of the patients after the operation. The VAS and Japanese Orthopedic Association scores showed improved clinical outcomes, from 7.86 ± 1.72 and 11.13 ± 2.19 preoperatively to 2.13 ± 1.40 and 14.26 ± 3.03 postoperatively, respectively. The mean survival time was 9.5 months (range, 5–26 months). Dural tear occurred in 1 patient. Wound infections, instrumentation failure, and postoperative death were not observed. Among our cases and other cases reported in the literature, 72% of the patients were treated with simple anterior or posterior operation, and only 12% of the patients (3/25) underwent complex combined anterior and posterior operation. Metastatic upper cervical spine disease is not a rare occurrence. Balancing the perspective of patients on palliative surgery concerning the clinical benefits of operation versus its operative risks can assist the decision for surgery. PMID:27149472

  8. Impact of constrained dual-screw anchorage on holding strength and the resistance to cyclic loading in anterior spinal deformity surgery: a comparative biomechanical study.

    PubMed

    Koller, Heiko; Fierlbeck, Johann; Auffarth, Alexander; Niederberger, Alfred; Stephan, Daniel; Hitzl, Wolfgang; Augat, Peter; Zenner, Juliane; Blocher, Martina; Blocher, Martina; Resch, Herbert; Mayer, Michael

    2014-03-15

    Biomechanical in vitro laboratory study. To compare the biomechanical performance of 3 fixation concepts used for anterior instrumented scoliosis correction and fusion (AISF). AISF is an ideal estimate for selective fusion in adolescent idiopathic scoliosis. Correction is mediated using rods and screws anchored in the vertebral bodies. Application of large correction forces can promote early weakening of the implant-vertebra interfaces, with potential postoperative loss of correction, implant dislodgment, and nonunion. Therefore, improvement of screw-rod anchorage characteristics with AISF is valuable. A total of 111 thoracolumbar vertebrae harvested from 7 human spines completed a testing protocol. Age of specimens was 62.9 ± 8.2 years. Vertebrae were potted in polymethylmethacrylate and instrumented using 3 different devices with identical screw length and unicortical fixation: single constrained screw fixation (SC fixation), nonconstrained dual-screw fixation (DNS fixation), and constrained dual-screw fixation (DC fixation) resembling a novel implant type. Mechanical testing of each implant-vertebra unit using cyclic loading and pullout tests were performed after stress tests were applied mimicking surgical maneuvers during AISF. Test order was as follows: (1) preload test 1 simulating screw-rod locking and cantilever forces; (2) preload test 2 simulating compression/distraction maneuver; (3) cyclic loading tests with implant-vertebra unit subjected to stepwise increased cyclic loading (maximum: 200 N) protocol with 1000 cycles at 2 Hz, tests were aborted if displacement greater than 2 mm occurred before reaching 1000 cycles; and (4) coaxial pullout tests at a pullout rate of 5 mm/min. With each test, the mode of failure, that is, shear versus fracture, was noted as well as the ultimate load to failure (N), number of implant-vertebra units surpassing 1000 cycles, and number of cycles and related loads applied. Thirty-three percent of vertebrae surpassed 1000 cycles, 38% in the SC group, 19% in the DNS group, and 43% in the DC group. The difference between the DC group and the DNS group yielded significance (P = 0.04). For vertebrae not surpassing 1000 cycles, the number of cycles at implant displacement greater than 2 mm in the SC group was 648.7 ± 280.2 cycles, in the DNS group was 478.8 ± 219.0 cycles, and in the DC group was 699.5 ± 150.6 cycles. Differences between the SC group and the DNS group were significant (P = 0.008) as between the DC group and the DNS group (P = 0.0009). Load to failure in the SC group was 444.3 ± 302 N, in the DNS group was 527.7 ± 273 N, and in the DC group was 664.4 ± 371.5 N. The DC group outperformed the other constructs. The difference between the SC group and the DNS group failed significance (P = 0.25), whereas there was a significant difference between the SC group and the DC group (P = 0.003). The DC group showed a strong trend toward increased load to failure compared with the DNS group but without significance (P = 0.067). Surpassing 1000 cycles had a significant impact on the maximum load to failure in the SC group (P = 0.0001) and in the DNS group (P = 0.01) but not in the DC group (P = 0.2), which had the highest number of vertebrae surpassing 1000 cycles. Constrained dual-screw fixation characteristics in modern AISF implants can improve resistance to cyclic loading and pullout forces. DC constructs bear the potential to reduce the mechanical shortcomings of AISF.

  9. The Future of Biologic Coatings for Orthopaedic Implants

    PubMed Central

    Goodman, Stuart B.; Yao, Zhenyu; Keeney, Michael; Yang, Fan

    2013-01-01

    Implants are widely used for othopaedic applications such as fixing fractures, repairing nonunions, obtaining a joint arthrodesis, total joint arthroplasty, spinal reconstruction, and soft tissue anchorage. Previously, orthopaedic implants were designed simply as mechanical devices; the biological aspects of the implant were a byproduct of stable internal/external fixation of the device to the surrounding bone or soft tissue. More recently, biologic coatings have been incorporated into orthopaedic implants in order to modulate the surrounding biological environment. This opinion article reviews current and potential future use of biologic coatings for orthopaedic implants to facilitate osseointegration and mitigate possible adverse tissue responses including the foreign body reaction and implant infection. While many of these coatings are still in the preclinical testing stage, bioengineers, material scientists and surgeons continue to explore surface coatings as a means of improving clinical outcome of patients undergoing orthopaedic surgery. PMID:23391496

  10. Aggressive hemangioma of the spine in a pregnant female: a case report and literature review.

    PubMed

    Demirkale, İsmail; De Iure, Federico; Terzi, Silvia; Gasbarrini, Alessandro

    2016-01-01

    Type and timing of treatment for symptomatic hemangiomas in pregnant females are challenging due to fetus survival and conflicts in neurological recovery. In this article, we report a 40-year-old female patient at pregnancy week 23 with a complicated hemangioma at T1 level. Physical examination revealed an incomplete spastic paraplegia. Patient did not accept any surgery due to child's death risk. Patient was started corticoid treatment and no more weight bearing was allowed. At the 28th week of pregnancy, the patient underwent cesarean section immediately followed by selective arterial embolization, decompression, fixation, and radiotherapy. At two-year follow-up, the patient was pain free, without any signs of local recurrence and with complete neurological recovery. A multidisciplinary approach is mandatory to save the life of the fetus without damaging the spinal cord functions of the mother.

  11. Two-Stage Surgical Management of Multilevel Symptomatic Thoracic Haemangioma Using Ethanol and Iliac Crest Bone Graft

    PubMed Central

    Brahmajoshyula, Venkatramana; Mayi, Shivanand; Teegala, Suman

    2014-01-01

    This article presents a 56-year-old obese female who presented with back pain and progressive weakness in her lower limbs for three months. She was bed-ridden for one week before reporting to our hospital. Plain radiographs showed vertical striations in multiple vertebrae classical of haemangioma. Magnetic resonance imaging (MRI) spine revealed multiple thoracic and lumbar vertebral haemangiomas. Extra osseous extension of haemangioma at T12 was causing spinal cord compression. Two-stage surgery was performed with absolute alcohol (ethanol) injection followed by pedicle screw fixation and decompression with tricortical iliac crest bone graft into the vertebral body. Postoperatively rapid neurological improvement was seen. After three weeks, she could walk independently. One year later, computed tomography showed complete incorporation of bone graft and maintained vertebral body height. MRI showed complete resolution of the cord edema at T12. These findings indicated diminished vascularity of the tumor. PMID:25187869

  12. Identifying motor and sensory myelinated axons in rabbit peripheral nerves by histochemical staining for carbonic anhydrase and cholinesterase activities

    NASA Technical Reports Server (NTRS)

    Riley, Danny A.; Sanger, James R.; Matloub, Hani S.; Yousif, N. John; Bain, James L. W.

    1988-01-01

    Carbonic anhydrase (CA) and cholinesterase (CE) histochemical staining of rabbit spinal nerve roots and dorsal root ganglia demonstrated that among the reactive myeliated axons, with minor exceptions, sensory axons were CA positive and CE negative whereas motor axons were CA negative and CE positive. The high specificity was achieved by adjusting reaction conditions to stain subpopulations of myelinated axons selectively while leaving 50 percent or so unstained. Fixation with glutaraldehyde appeared necessary for achieving selectivity. Following sciatic nerve transection, the reciprocal staining pattern persisted in damaged axons and their regenerating processes which formed neuromas within the proximal nerve stump. Within the neuromas, CA-stained sensory processes were elaborated earlier and in greater numbers than CE-stained regenerating motor processes. The present results indicate that histochemical axon typing can be exploited to reveal heterogeneous responses of motor and sensory axons to injury.

  13. Olfactory preservation during anterior interhemispheric approach for anterior skull base lesions: technical note.

    PubMed

    Matano, Fumihiro; Murai, Yasuo; Mizunari, Takayuki; Tateyama, Kojiro; Kobayashi, Shiro; Adachi, Koji; Kamiyama, Hiroyasu; Morita, Akio; Teramoto, Akira

    2016-01-01

    Anosmia is not a rare complication of surgeries that employ the anterior interhemispheric approach. Here, we present a fibrin-gelatin fixation method that provides reinforcement and moisture to help preserve the olfactory nerve when using the anterior interhemispheric approach and describe the results and outcomes of this technique. We analyze the outcomes with this technique in 45 patients who undergo surgery for aneurysms, brain tumors, or other pathologies via the anterior interhemispheric approach. Anosmia occurred in 4 patients (8.8%); it was transient in 2 (4.4%) and permanent in the remaining 2 (4.4%). Brain tumors clearly attached to the olfactory nerve were resected in the patients with permanent anosmia. We found a significant difference in the presence of anosmia between patients with or without lesions that were attaching the olfactory nerve (p = 0.011). Our results suggested that fibrin-gelatin fixation method can reduce the reported risk of anosmia. However, the possibility of olfactory nerve damage is relatively high when operating on brain tumors attaching olfactory nerve.

  14. Use of the bioactive resorbable plate system for zygoma and zygomatic arch replacement and fixation with modified Crockett's method for maxillectomy: A technical note.

    PubMed

    Sukegawa, Shintaro; Kanno, Takahiro; Shibata, Akane; Matsumoto, Kenichi; Sukegawa-Takahashi, Yuka; Sakaida, Kyousuke; Furuki, Yoshihiko

    2017-07-01

    As a surgical approach targeting the pterygopalatine fossa following maxillary cancer due to tumor invasion, Crockett's method is conventional and useful. However, if the tumor is confined to the area between the maxilla and pterygopalatine fossa, it is not necessary to include the zygomatico-orbital in the access osteotomy, and the orbital floor may be preserved. Depending on the range of tumor invasion, the current study reports a more minimally invasive, modified Crockett's surgery that may be considered, which includes resection with modified osteotomy lines and repositioning with fixation of the zygoma and zygomatic arch following maxillary cancer ablation. In addition, the majority of patients with advanced maxillary cancer may require postoperative radiotherapy or chemoradiotherapy following maxillectomy according to several guidelines. Therefore, using a low-profile bioactive resorbable plate system as a method of repositioning and fixing the resected and preserved zygoma and zygomatic arch may be more effective in this modified Crockett's method for maxillectomy.

  15. Reconstruction of Long Bone Infections Using the Induced Membrane Technique: Tips and Tricks.

    PubMed

    Mauffrey, Cyril; Hake, Mark E; Chadayammuri, Vivek; Masquelet, Alain-Charles

    2016-06-01

    The management of posttraumatic long bone osteomyelitis remains a challenging clinical problem. A systematic approach is necessary, beginning with eradication of the infected bone and soft tissue. There are a number of options for reconstruction of the remaining bone defect, including the induced membrane technique developed by Masquelet. We describe our technique for the 2-stage treatment of long bone osteomyelitis. The first stage involves a radical debridement, stabilization of the bone with either external fixation or an antibiotic-coated intramedullary nail, and placement of a polymethylmethacrylate spacer. The second stage includes excision of the spacer and placement of autologous bone graft. Various resection methods, fixation strategies, antibiotic additives, and types of bone grafts or substitutes can be used. The purpose of our technical article is to share our personal experience and describe several nuances that are critical for the success of this treatment strategy. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  16. Endoscope-Assisted Transoral Fixation of Mandibular Condyle Fractures: Submandibular Versus Transoral Endoscopic Approach.

    PubMed

    Hwang, Na-Hyun; Lee, Yoon-Hwan; You, Hi-Jin; Yoon, Eul-Sik; Kim, Deok-Woo

    2016-07-01

    In recent years, endoscope-assisted transoral approach for condylar fracture treatment has attracted much attention. However, the surgical approach is technically challenging: the procedure requires specialized instruments and the surgeons experience a steep learning curve. During the transoral endoscopic (TE) approach several instruments are positioned through a narrow oral incision making endoscope maneuvering very difficult. For this reason, the authors changed the entry port of the endoscope from transoral to submandibular area through a small stab incision. The aim of this study is to assess the advantage of using the submandibular endoscopic intraoral approach (SEI).The SEI approach requires intraoral incision for fracture reduction and fixation, and 4 mm size submandibular stab incision for endoscope and traction wires. Fifteen patients with condyle neck and subcondyle fractures were operated under the submandibular approach and 15 patients with the same diagnosis were operated under the standard TE approach.The SEI approach allowed clear visualization of the posterior margin of the ramus and condyle, and the visual axis was parallel to the condyle ramus unit. The TE approach clearly shows the anterior margin of the condyle and the sigmoid notch. The surgical time of the SEI group was 128 minutes and the TE group was 120 minutes (P >0.05). All patients in the TE endoscope group were fixated with the trocar system, but only 2 lower neck fracture patients in the SEI group required a trocar. The other 13 subcondyle fractures were fixated with an angulated screw driver (P <0.05). There were no differences in complication and surgical outcomes.The submandibular endoscopic approach has an advantage of having more space with good visualization, and facilitated the use of an angulated screw driver.

  17. Sagittal imbalance treated with L5 pedicle subtraction osteotomy with short lumbar fusion from L4 to sacrum using four screws into L4 for enhanced fixation two additional vertebral screws: a technical note.

    PubMed

    Wangdi, Kuenzang; Otsuki, Bungo; Fujibayashi, Shunsuke; Tanida, Shimei; Masamoto, Kazutaka; Matsuda, Shuichi

    2018-02-07

    To report on suggested technique with four screws in a single vertebra (two pedicle screws and two direct vertebral body screws) for enhanced fixation with just one level cranially to a pedicle subtraction osteotomy (PSO). A 60-year-old woman underwent L4/5 fusion surgery for degenerative spondylolisthesis. Two years later, she was unable to stand upright even for a short time because of lumbar kyphosis caused by subsidence of the fusion cage and of Baastrup syndrome in the upper lumbar spine [sagittal vertical axis (SVA) of 114 mm, pelvic incidence of 75°, and lumbar lordosis (LL) of 41°]. She underwent short-segment fusion from L4 to the sacrum with L5 pedicle subtraction osteotomy. We reinforced the construct with two vertebral screws at L4 in addition to the conventional L4 pedicle screws. After the surgery, her sagittal parameters were improved (SVA, 36 mm; LL, 54°). Two years after the corrective surgery, she maintained a low sagittal vertical axis though high residual pelvic tilt indicated that the patient was still compensating for residual sagittal misalignment. PSO surgery for sagittal imbalance usually requires a long fusion at least two levels above and below the osteotomy site to achieve adequate stability and better global alignment. However, longer fixation may decrease the patients' quality of life and cause a proximal junctional failure. Our novel technique may shorten the fixation area after osteotomy surgery. These slides can be retrieved under Electronic Supplementary Material.

  18. Management of distal humeral coronal shear fractures

    PubMed Central

    Yari, Shahram S; Bowers, Nathan L; Craig, Miguel A; Reichel, Lee M

    2015-01-01

    Coronal shear fractures of the distal humerus are rare, complex fractures that can be technically challenging to manage. They usually result from a low-energy fall and direct compression of the distal humerus by the radial head in a hyper-extended or semi-flexed elbow or from spontaneous reduction of a posterolateral subluxation or dislocation. Due to the small number of soft tissue attachments at this site, almost all of these fractures are displaced. The incidence of distal humeral coronal shear fractures is higher among women because of the higher rate of osteoporosis in women and the difference in carrying angle between men and women. Distal humeral coronal shear fractures may occur in isolation, may be part of a complex elbow injury, or may be associated with injuries proximal or distal to the elbow. An associated lateral collateral ligament injury is seen in up to 40% and an associated radial head fracture is seen in up to 30% of these fractures. Given the complex nature of distal humeral coronal shear fractures, there is preference for operative management. Operative fixation leads to stable anatomic reduction, restores articular congruity, and allows initiation of early range-of-motion movements in the majority of cases. Several surgical exposure and fixation techniques are available to reconstruct the articular surface following distal humeral coronal shear fractures. The lateral extensile approach and fixation with countersunk headless compression screws placed in an anterior-to-posterior fashion are commonly used. We have found a two-incision approach (direct anterior and lateral) that results in less soft tissue dissection and better outcomes than the lateral extensile approach in our experience. Stiffness, pain, articular incongruity, arthritis, and ulnohumeral instability may result if reduction is non-anatomic or if fixation fails. PMID:25984515

  19. [The external patello-tibial transfixation (EPTT). Part II: Clinical application and results].

    PubMed

    Ishaque, B; Gotzen, L; Ziring, E; Petermann, J

    1999-07-01

    In part I of the paper the biomechanical and technical background of the EPTT using the MPT fixator and the indications for this procedure have been described. In part II we report about the clinical application of the EPTT in 67 patients with a wide spectrum of repairs and reconstructions of the extensor mechanism. 48 patients had fresh injuries, 18 of them with severe concomitant knee lesions and 19 patients had neglected rsp. unsuccessfully operated injuries. There were 4 deep infections, two of them related to the MPT fixator. In the patients with uneventful healing the fixator remained in place for 7.3 weeks in average. The clinical, isokinetic and radiological results were reviewed in 17 patients with an average follow-up time of 37.3 months. There were 5 patients with partial patellectomy and tendon reattachment because of lower patella pole comminution and 12 patients with tendon reattachment ruptured at the inferior patella pole or suture repair in midsubstance rupture. The clinical results according to the IKDC score were rated in 3 patients as normal, in 10 patients as nearly normal and in 4 patients as abnormal. This rating was highly dependend on the subjective judgement by the patients who considered their operated knees not as normal as the contralateral knees. From our clinical experiences and results we can derive that the EPTT enables the surgical management of extensor mechanism disruptions with a minimum of internal fixation material and provides a safe protection of the repairs and reconstructions during the healing period. The EPTT allows immediate unrestricted functional rehabilitation and early walking without crutches. Thus the EPTT represents an effective alternative to the patello-tibial cerclage with a wire or synthetic ligaments.

  20. Biomechanics of the lower thoracic spine after decompression and fusion: a cadaveric analysis.

    PubMed

    Lubelski, Daniel; Healy, Andrew T; Mageswaran, Prasath; Benzel, Edward C; Mroz, Thomas E

    2014-09-01

    Few studies have evaluated the extent of biomechanical destabilization of thoracic decompression on the upper and lower thoracic spine. The present study evaluates lower thoracic spinal stability after laminectomy, unilateral facetectomy, and unilateral costotransversectomy in thoracic spines with intact sternocostovertebral articulations. To assess the biomechanical impact of decompression and fixation procedures on lower thoracic spine stability. Biomechanical cadaveric study. Sequential surgical decompression (laminectomy, unilateral facetectomy, unilateral costotransversectomy) and dorsal fixation were performed on the lower thoracic spine (T8-T9) of human cadaveric spine specimens with intact rib cages (n=10). An industrial robot was used to apply pure moments to simulate flexion-extension (FE), lateral bending (LB), and axial rotation (AR) in the intact specimens and after decompression and fixation. Global range of motion (ROM) between T1-T12 and intrinsic ROM between T7-T11 were measured for each specimen. The decompression procedures caused no statistically significant change in either global or intrinsic ROM compared with the intact state. Instrumentation, however, reduced global motion for AR (45° vs. 30°, p=.0001), FE (24° vs. 19°, p=.02), and LB (47° vs. 36°, p=.0001) and for intrinsic motion for AR (17° vs. 4°, p=.0001), FE (8° vs. 1°, p=.0001), and LB (12° vs. 1°, p=.0001). No significant differences were identified between decompression of the upper versus lower thoracic spine, with trends toward significantly greater ROM for AR and lower ROM for LB in the lower thoracic spine. The lower thoracic spine was not destabilized by sequential unilateral decompression procedures. Addition of dorsal fixation increased segment rigidity at intrinsic levels and also reduced overall ROM of the lower thoracic spine to a greater extent than did fusing the upper thoracic spine (level of the true ribs). Despite the lack of true ribs, the lower thoracic spine was not significantly different compared with the upper thoracic spine in FE and LB after decompression, although there were trends toward significance for greater AR after decompression. In certain patients, instrumentation may not be needed after unilateral decompression of the lower thoracic spine; further validation and additional clinical studies are warranted. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. [Exploratory study of 3D printing technique in the treatment of basilar invagination and atlantoaxial dislocation].

    PubMed

    Yin, Yiheng; Yu, Xinguang; Tong, Huaiyu; Xu, Tao; Wang, Peng; Qiao, Guangyu

    2015-10-06

    To investigate the clinical application value of the 3D printing technique in the treatment of basilar invagination and atlantoaxial dislocation. From January 2013 to September 2013, 10 patients with basilar invagination and atlantoaxial dislocation needing posterior fixation undertook 3D printing modes at the Department of Neurosurgery in PLA General Hospital. The 1:1 size models were established from skull base to C4 level with different colors between bone structures and vertebral arteries. The simulation of screw insertion was made to investigate the fixation plan and ideal entry point to avoid vertebral artery injury. After obtaining the individual screw insertion data in 3D printing modes, the according surgical operations were performed. The actual clinical results and virtual screw data in 3D printing mode were compared with each other. The 3D printing modes revealed that all the 10 patients had the dysplasia or occipitalized C1 posterior arch indicating C1 posterior arch screw implantation was not suitable. C1 lateral masses were chosen as the screws entry points. C2 screws were designed individually based on the 3D printing modes as follows: 3 patients with aberrant vertebral artery or narrow C2 pedicle less than 3.5 mm were not suitable for pedicle screw implantation. Among the 3 patients, 1 was fixed with C2 laminar screw, and 1 with C2-3 transarticular screw and 1 with C3 pedicle screw (also combined with congenital C2-3 vertebral fusion). Two patients with narrow C2 pedicle between 3.5 and 4mm were designed to choose pedicle screw fixation after 3D printing mode evaluation. One patient with C1 lateral mass vertically dislocated axis was planned with C1-2 transarticular screw fixation. All the other patients were planned with C2 pedicle screws. All the 10 patients had operation designed as the 3D printing modes schemes. The follow-up ranged from 12 to 18 months and all the patients recovered from the clinical symptoms and the bony fusion attained to 100%. 3D printing mode could provide thorough information of the bony structure abnormalities and route of vertebral artery. It is helpful for setting operation strategy and designing screw entry point and trajectory and avoiding vertebral artery and spinal cord injury and thus deserves generalization.

  2. Videoexoscopic real-time intraoperative navigation for spinal neurosurgery: a novel co-adaptation of two existing technology platforms, technical note.

    PubMed

    Huang, Meng; Barber, Sean Michael; Steele, William James; Boghani, Zain; Desai, Viren Rajendrakumar; Britz, Gavin Wayne; West, George Alexander; Trask, Todd Wilson; Holman, Paul Joseph

    2018-06-01

    Image-guided approaches to spinal instrumentation and interbody fusion have been widely popularized in the last decade [1-5]. Navigated pedicle screws are significantly less likely to breach [2, 3, 5, 6]. Navigation otherwise remains a point reference tool because the projection is off-axis to the surgeon's inline loupe or microscope view. The Synaptive robotic brightmatter drive videoexoscope monitor system represents a new paradigm for off-axis high-definition (HD) surgical visualization. It has many advantages over the traditional microscope and loupes, which have already been demonstrated in a cadaveric study [7]. An auxiliary, but powerful capability of this system is projection of a second, modifiable image in a split-screen configuration. We hypothesized that integration of both Medtronic and Synaptive platforms could permit the visualization of reconstructed navigation and surgical field images simultaneously. By utilizing navigated instruments, this configuration has the ability to support live image-guided surgery or real-time navigation (RTN). Medtronic O-arm/Stealth S7 navigation, MetRx, NavLock, and SureTrak spinal systems were implemented on a prone cadaveric specimen with a stream output to the Synaptive Display. Surgical visualization was provided using a Storz Image S1 platform and camera mounted to the Synaptive robotic brightmatter drive. We were able to successfully technically co-adapt both platforms. A minimally invasive transforaminal lumbar interbody fusion (MIS TLIF) and an open pedicle subtraction osteotomy (PSO) were performed using a navigated high-speed drill under RTN. Disc Shaver and Trials under RTN were implemented on the MIS TLIF. The synergy of Synaptive HD videoexoscope robotic drive and Medtronic Stealth platforms allow for live image-guided surgery or real-time navigation (RTN). Off-axis projection also allows upright neutral cervical spine operative ergonomics for the surgeons and improved surgical team visualization and education compared to traditional means. This technique has the potential to augment existing minimally invasive and open approaches, but will require long-term outcome measurements for efficacy.

  3. Fixation of competing strategies when interacting agents differ in the time scale of strategy updating

    NASA Astrophysics Data System (ADS)

    Zhang, Jianlei; Weissing, Franz J.; Cao, Ming

    2016-09-01

    A commonly used assumption in evolutionary game theory is that natural selection acts on individuals in the same time scale; e.g., players use the same frequency to update their strategies. Variation in learning rates within populations suggests that evolutionary game theory may not necessarily be restricted to uniform time scales associated with the game interaction and strategy adaption evolution. In this study, we remove this restricting assumption by dividing the population into fast and slow groups according to the players' strategy updating frequencies and investigate how different strategy compositions of one group influence the evolutionary outcome of the other's fixation probabilities of strategies within its own group. Analytical analysis and numerical calculations are performed to study the evolutionary dynamics of strategies in typical classes of two-player games (prisoner's dilemma game, snowdrift game, and stag-hunt game). The introduction of the heterogeneity in strategy-update time scales leads to substantial changes in the evolution dynamics of strategies. We provide an approximation formula for the fixation probability of mutant types in finite populations and study the outcome of strategy evolution under the weak selection. We find that although heterogeneity in time scales makes the collective evolutionary dynamics more complicated, the possible long-run evolutionary outcome can be effectively predicted under technical assumptions when knowing the population composition and payoff parameters.

  4. Metastatic Spine Tumor Surgery: A Comparative Study of Minimally Invasive Approach Using Percutaneous Pedicle Screws Fixation Versus Open Approach.

    PubMed

    Kumar, Naresh; Malhotra, Rishi; Maharajan, Karthikeyan; Zaw, Aye S; Wu, Pang Hung; Makandura, Milindu C; Po Liu, Gabriel Ka; Thambiah, Joseph; Wong, Hee-Kit

    2017-10-01

    Prospective cohort study. Minimally invasive spinal surgery (MISS) has been gaining recognition in patients with metastatic spine disease (MSD). The advantages are reduction in blood loss, hospital stay, and postoperative morbidity. Most of the studies were case series with very few comparing the outcomes of MISS to open approaches. To evaluate and compare the clinical and perioperative outcomes of MISS versus open approach in patients with symptomatic MSD, who underwent posterior spinal stabilization and/or decompression. Our study included 45 MSD patients; 27 managed by MISS and 18 by open approach. All patients had MSD presenting with symptoms of neurological deficit, spinal instability, or both. Preoperative, intraoperative, and postoperative data were collected for comparison of the 2 approaches. All patients were followed up until the end of study period (maximum up to 4 years from time of surgery) or till their demise. The clinical outcome measures were pain control, neurological and functional status, whereas perioperative outcomes were blood loss, operative time, length of hospital stay, and time taken to initiate radiotherapy/chemotherapy after index surgery. Majority of patients in both groups showed improvement in pain, neurological status, independent ambulation, and ECOG score in the postoperative period with no significant differences between the 2 groups. There was a significant reduction in intraoperative blood loss (621 mL less, P<0.001) in the MISS group. The average time to initiate radiotherapy after surgery was 13 days (range, 12-16 d) in MISS and 24 days (range, 16-40 d) in the open group. This difference was statistically significant (P<0.001). Operative time and duration of hospital stay were also favorable in the MISS group, although the differences were not significant. MISS is comparable with open approach demonstrating similar improvements in clinical outcomes, that is pain control, neurological and functional status. MISS approaches have also shown promising results due to lesser intraoperative blood loss and allowing earlier radiotherapy/chemotherapy.

  5. Sensorimotor integration of vision and proprioception for obstacle crossing in ambulatory individuals with spinal cord injury.

    PubMed

    Malik, Raza Naseem; Cote, Rachel; Lam, Tania

    2017-01-01

    Skilled walking, such as obstacle crossing, is an essential component of functional mobility. Sensorimotor integration of visual and proprioceptive inputs is important for successful obstacle crossing. The objective of this study was to understand how proprioceptive deficits affect obstacle-crossing strategies when controlling for variations in motor deficits in ambulatory individuals with spinal cord injury (SCI). Fifteen ambulatory individuals with SCI and 15 able-bodied controls were asked to step over an obstacle scaled to their motor abilities under full and obstructed vision conditions. An eye tracker was used to determine gaze behaviour and motion capture analysis was used to determine toe kinematics relative to the obstacle. Combined, bilateral hip and knee proprioceptive sense (joint position sense and movement detection sense) was assessed using the Lokomat and customized software controls. Combined, bilateral hip and knee proprioceptive sense in subjects with SCI varied and was significantly different from able-bodied subjects. Subjects with greater proprioceptive deficits stepped higher over the obstacle with their lead and trail limbs in the obstructed vision condition compared with full vision. Subjects with SCI also glanced at the obstacle more frequently and with longer fixation times compared with controls, but this was not related to proprioceptive sense. This study indicates that ambulatory individuals with SCI rely more heavily on vision to cross obstacles and show impairments in key gait parameters required for successful obstacle crossing. Our data suggest that proprioceptive deficits need to be considered in rehabilitation programs aimed at improving functional mobility in ambulatory individuals with SCI. This work is unique since it examines the contribution of combined, bilateral hip and knee proprioceptive sense on the recovery of skilled walking function, in addition to characterizing gaze behavior during a skilled walking task in people with motor-incomplete spinal cord injury. Copyright © 2017 the American Physiological Society.

  6. Fortifying the Bone-Implant Interface Part 1: An In Vitro Evaluation of 3D-Printed and TPS Porous Surfaces.

    PubMed

    MacBarb, Regina F; Lindsey, Derek P; Bahney, Chelsea S; Woods, Shane A; Wolfe, Mark L; Yerby, Scott A

    2017-01-01

    An aging society and concomitant rise in the incidence of impaired bone health have led to the need for advanced osteoconductive spinal implant surfaces that promote greater biological fixation ( e.g. for interbody fusion cages, sacroiliac joint fusion implants, and artificial disc replacements). Additive manufacturing, i.e. 3D-printing, may improve bone integration by generating biomimetic spinal implant surfaces that mimic bone morphology. Such surfaces may foster an enhanced cellular response compared to traditional implant surfacing processes. This study investigated the response of human osteoblasts to additive manufactured (AM) trabecular-like titanium implant surfaces compared to traditionally machined base material with titanium plasma spray (TPS) coated surfaces, with and without a nanocrystalline hydroxyapatite (HA) coating. For TPS-coated discs, wrought Ti6Al4V ELI was machined and TPS-coating was applied. For AM discs, Ti6Al4V ELI powder was 3D-printed to form a solid base and trabecular-like porous surface. The HA-coating was applied via a precipitation dip-spin method. Surface porosity, pore size, thickness, and hydrophilicity were characterized. Initial cell attachment, proliferation, alkaline phosphatase (ALP) activity, and calcium production of hFOB cells ( n =5 per group) were measured. Cells on AM discs exhibited expedited proliferative activity. While there were no differences in mean ALP expression and calcium production between TPS and AM discs, calcium production on the AM discs trended 48% higher than on TPS discs ( p =0.07). Overall, HA-coating did not further enhance results compared to uncoated TPS and AM discs. Results demonstrate that additive manufacturing allows for controlled trabecular-like surfaces that promote earlier cell proliferation and trends toward higher calcium production than TPS coating. Results further showed that nanocrystalline HA may not provide an advantage on porous titanium surfaces. Additive manufactured porous titanium surfaces may induce a more osteogenic environment compared to traditional TPS, and thus present as an attractive alternative to TPS-coating for orthopedic spinal implants.

  7. A systematic review to assess comparative effectiveness studies in epidural steroid injections for lumbar spinal stenosis and to estimate reimbursement amounts.

    PubMed

    Bresnahan, Brian W; Rundell, Sean D; Dagadakis, Marissa C; Sullivan, Sean D; Jarvik, Jeffrey G; Nguyen, Hiep; Friedly, Janna L

    2013-08-01

    To systematically appraise published comparative effectiveness evidence (clinical and economic) of epidural steroid injections (ESI) for lumbar spinal stenosis and to estimate Medicare reimbursement amounts for ESI procedures. TYPE: Systematic review. PubMed, Embase, and CINAHL were searched through August 2012 for key words that pertain to low back pain, spinal stenosis or sciatica, and epidural steroid injection. We used institutional and Medicare reimbursement amounts for our cost estimation. Articles published in English that assessed ESIs for adults with lumbar spinal stenosis versus a comparison intervention were included. Our search identified 146 unique articles, and 138 were excluded due to noncomparative study design, not having a study population with lumbar spinal stenosis, not having an appropriate outcome, or not being in English. We fully summarized 6 randomized controlled trials and 2 large observational studies. Randomized controlled trial articles were reviewed, and the study population, sample size, treatment groups, ESI dosage, ESI approaches, concomitant interventions, outcomes, and follow-up time were reported. Descriptive resource use estimates for ESIs were calculated with use of data from our institution during 2010 and Medicare-based reimbursement amounts. ESIs or anesthetic injections alone resulted in better short-term improvement in walking distance compared with control injections. However, there were no longer-term differences. No differences between ESIs versus anesthetic in self-reported improvement in pain were reported. Transforaminal approaches had better improvement in pain scores (≤4 months) compared with interlaminar injections. Two observational studies indicated increased rates of lumbar ESI in Medicare beneficiaries. Our sample included 279 patients who received at least 1 ESI during 2010, with an estimated mean total outpatient reimbursement for one ESI procedure "event" to be $637, based on 2010 Medicare reimbursement amounts ($505 technical and $132 professional payments). This systematic review of ESI for treating lumbar spinal stenosis found a limited amount of data that suggest that ESI is effective in some patients for improving select short-term outcomes, but results differed depending on study design, outcome measures used, and comparison groups evaluated. Overall, there are relatively few comparative clinical or economic studies for ESI procedures for lumbar spinal stenosis in adults, which indicated a need for additional evidence. Copyright © 2013. Published by Elsevier Inc.

  8. Simple New Screw Insertion Technique without Extraction for Broken Pedicle Screws.

    PubMed

    Kil, Jin-Sang; Park, Jong-Tae

    2018-05-01

    Spinal transpedicular screw fixation is widely performed. Broken pedicle screw rates range from 3%-7.1%. Several techniques have been described for extraction of broken pedicle screws. However, most of these techniques require special instruments. We describe a simple, modified technique for management of broken pedicle screws without extraction. No special instruments or drilling in an adjacent pedicle are required. We used a high-speed air drill with a round burr. With C-arm fluoroscopy guidance, the distal fragment of a broken pedicle screw was palpated using free-hand technique through the screw entry hole. A high-speed air drill with a round burr (not a diamond burr) was inserted through the hole. Drilling began slowly and continued until enough space was obtained for new screw insertion. Using this space, we performed new pedicle screw fixation medially alongside the distal fragment of the broken pedicle screw. We performed the insertion with a previously used entry hole and pathway in the pedicle. The same size pedicle screw was used. Three patients were treated with this modified technique. New screw insertion was successful in all cases after partial drilling of the distal broken pedicle screw fragment. There were no complications, such as screw loosening, dural tears, or root injury. We describe a simple, modified technique for management of broken pedicle screws without extraction. This technique is recommended in patients who require insertion of a new screw. Copyright © 2017. Published by Elsevier Inc.

  9. Saving the On-Scene Time for Out-of-Hospital Cardiac Arrest Patients: The Registered Nurses' Role and Performance in Emergency Medical Service Teams.

    PubMed

    Lin, Ming-Wei; Wu, Che-Yu; Pan, Chih-Long; Tian, Zhong; Wen, Jyh-Horng; Wen, Jet-Chau

    2017-01-01

    For out-of-hospital cardiac arrest (OHCA) patients, every second is vital for their life. Shortening the prehospital time is a challenge to emergency medical service (EMS) experts. This study focuses on the on-scene time evaluation of the registered nurses (RNs) participating in already existing EMS teams, in order to explore their role and performance in different EMS cases. In total, 1247 cases were separated into trauma and nontrauma cases. The nontrauma cases were subcategorized into OHCA (NT-O), critical (NT-C), and noncritical (NT-NC) cases, whereas the trauma cases were subcategorized into collar-and-spinal board fixation (T-CS), fracture fixation (T-F), and general trauma (T-G) cases. The average on-scene time of RN-attended cases showed a decrease of 21.05% in NT-O, 3.28% in NT-C, 0% in NT-NC, 18.44% in T-CS, 13.56% in T-F, and 3.46% in T-G compared to non-RN-attended. In NT-O and T-CS cases, the RNs' attendance can notably save the on-scene time with a statistical significance ( P = .016 and .017, resp.). Furthermore, the return of spontaneous circulation within two hours (ROSC 2 h ) rate in the NT-O cases was increased by 12.86%. Based on the findings, the role of RNs in the EMTs could save the golden time in the prehospital medical care in Taiwan.

  10. Trauma of the upper cervical spine: focus on vertical atlantoaxial dislocation.

    PubMed

    Pissonnier, M L; Lazennec, J Y; Renoux, J; Rousseau, M A

    2013-10-01

    Traumatic ligament injuries of the craniovertebral junction, either isolated or associated with bone avulsion or fracture, often lead to death. These injuries are rare and underrated but are increasingly seen in emergency departments due to the improvement in initial on-scene management of accidents. Vertical atlantoaxial dislocation (AAD) is a specific lesion that was barely reported. Based on our experience, our goal was to systematically investigate the prevalence and prognosis of traumatic vertical AAD and discuss its management. All cervical CT scans performed at our institution between 2006 and 2010 for cervical trauma in adults were retrospectively reviewed. Based on the measurement of lateral mass index (LMI), defined as the gap between C1 and C2 articular facets, we identified three cases of traumatic vertical AAD in 300 CT scans. Their medical records were investigated. The incidence of vertical AAD was 1% in the exposed population. One case was an isolated vertical AAD and two were associated with a type II odontoid fracture. We report the first case in the literature of unilateral vertical AAD. Two patients died rapidly; the survivor was treated with occipitocervical fixation. Specific maneuvers were used for immobilization and reduction. This study found a not insignificant incidence of vertical AAD and a high lethality rate. LMI appears to be a relevant radiological criterion for this diagnosis, for which traction is contraindicated. Associated neurological or vascular damage should be suspected and investigated. In our experience, spinal surgical fixation is required because of major instability.

  11. Hybrid Instrumentation in Lumbar Spinal Fusion

    PubMed Central

    Danyali, Reza; Kueny, Rebecca; Huber, Gerd; Reichl, Michael; Richter, Alexander; Niemeyer, Thomas; Morlock, Michael; Püschel, Klaus; Übeyli, Hüseyin

    2017-01-01

    Study Design Ex vivo human cadaveric study. Objective The development or progression of adjacent segment disease (ASD) after spine stabilization and fusion is a major problem in spine surgery. Apart from optimal balancing of the sagittal profile, dynamic instrumentation is often suggested to prevent or impede ASD. Hybrid instrumentation is used to gain stabilization while allowing motion to avoid hypermobility in the adjacent segment. In this biomechanical study, the effects of two different hybrid instrumentations on human cadaver spines were evaluated and compared with a rigid instrumentation. Methods Eighteen human cadaver spines (T11–L5) were subdivided into three groups: rigid, dynamic, and hook comprising six spines each. Clinical parameters and initial mechanical characteristics were consistent among groups. All specimens received rigid fixation from L3–L5 followed by application of a free bending load of extension and flexion. The range of motion (ROM) for every segment was evaluated. For the rigid group, further rigid fixation from L1–L5 was applied. A dynamic Elaspine system (Spinelab AG, Winterthur, Switzerland) was applied from L1 to L3 for the dynamic group, and the hook group was instrumented with additional laminar hooks at L1–L3. ROM was then evaluated again. Results There was no significant difference in ROM among the three instrumentation techniques. Conclusion Based on this data, the intended advantage of a hybrid or dynamic instrumentation might not be achieved. PMID:28451509

  12. The insertional torque of a pedicle screw has a positive correlation with bone mineral density in posterior lumbar pedicle screw fixation.

    PubMed

    Lee, J H; Lee, J-H; Park, J W; Shin, Y H

    2012-01-01

    In patients with osteoporosis there is always a strong possibility that pedicle screws will loosen. This makes it difficult to select the appropriate osteoporotic patient for a spinal fusion. The purpose of this study was to determine the correlation between bone mineral density (BMD) and the magnitude of torque required to insert a pedicle screw. To accomplish this, 181 patients with degenerative disease of the lumbar spine were studied prospectively. Each underwent dual-energy x-ray absorptiometry (DEXA) and intra-operative measurement of the torque required to insert each pedicle screw. The levels of torque generated in patients with osteoporosis and osteopenia were significantly lower than those achieved in normal patients. Positive correlations were observed between BMD and T-value at the instrumented lumbar vertebrae, mean BMD and mean T-value of the lumbar vertebrae, and mean BMD and mean T-value of the proximal femur. The predictive torque (Nm) generated during pedicle screw insertion was [-0.127 + 1.62 × (BMD at the corresponding lumbar vertebrae)], as measured by linear regression analysis. The positive correlation between BMD and the maximum torque required to insert a pedicle screw suggests that pre-operative assessment of BMD may be useful in determining the ultimate strength of fixation of a device, as well as the number of levels that need to be fixed with pedicle screws in patients who are suspected of having osteoporosis.

  13. Anatomic Double Bundle single tunnel Foreign Material Free ACL-Reconstruction – a technical note

    PubMed Central

    Felmet, Gernot

    2011-01-01

    Summary The anterior cruciate ligament (ACL) consists of two bundles, the anteromedial (AM) and posterolateral bundle (PM). Double bundle reconstructions appear to give better rotational stability. The usual technique is to make two tunnels in the femur and two in the tibia. This is difficult and in small knees may not even be possible. We have developed a foreign material free press fit fixation for double bundle ACL reconstruction using a single femoral tunnel (R). This is based on the ALL PRESS FIT ACL reconstruction. It is suitable for the most common medium and, otherwise difficult, small sizes of knees. Method: Using diamond edged wet grinding hollow reamers, bone cylinders in different diameters are harvested from the implantation tunnels of the tibia and femur and used for the press fit fixation. Using the press fit technique the graft is first fixed in tibia. It is then similarly fixed under tension in the femoral side with the knee in 120 degree flexion. This is called Bottom To Top Fixation (BTT). On extending the knee the graft tension is self adapting. Depending on the size of the individual knee, the diameter of the femoral bone plug is varied from 8 to 13 mm to achieve an anatomic spread with a double bundle-like insertion. The tibia tunnel can be applied with two 7 or 8 mm diameter tunnels overlapping to a semi oval tunnel between 10 to 13 mm. Results: Since May 2003 we have carried out ACL-reconstructions with Hamstring grafts without foreign material using the ALL PRESS FIT technique. Initially, an 8 mm press fit fixation was used proximally with good results. Since April 2008, the range of diameters was increased up to 13 mm. The results of the Lachman tests have been good to excellent. Results of the Pivot shift test suggested more stability with femoral broader diameters of 9,5 to 13 mm. Conclusions: The foreign material free fixation of ham-string in the ALL PRESS FIT Bottom To Top Fixation is a successful method for ACL Reconstruction. The Diamond Instruments and tubed guiding devices are precise, reliable and easy to manage. On this basis a double bundle reconstruction is achieved using a single tunnel. A broad anatomic femoral insertion with autogenous bone plugs inserted near the cortex seems to improve rotational stability. PMID:23738263

  14. Modified fenestration with restorative spinoplasty for lumbar spinal stenosis.

    PubMed

    Matsudaira, Ko; Yamazaki, Takashi; Seichi, Atsushi; Hoshi, Kazuto; Hara, Nobuhiro; Ogiwara, Satoshi; Terayama, Sei; Chikuda, Hirotaka; Takeshita, Katsushi; Nakamura, Kozo

    2009-06-01

    The authors developed an original procedure, modified fenestration with restorative spinoplasty (MFRS) for the treatment of lumbar spinal stenosis. The first step is to cut the spinous process in an L-shape, which is caudally reflected. This procedure allows easy access to the spinal canal, including lateral recesses, and makes it easy to perform a trumpet-style decompression of the nerve roots without violating the facet joints. After the decompression of neural tissues, the spinous process is anatomically restored (spinoplasty). The clinical outcomes at 2 years were evaluated using the Japanese Orthopaedic Association (JOA) scale and patients' satisfaction. Radiological follow-up included radiographs and CT. Between January 2000 and December 2002, 109 patients with neurogenic intermittent claudication with or without mild spondylolisthesis underwent MFRS. Of these, 101 were followed up for at least 2 years (follow-up rate 93%). The average score on the self-administered JOA scale in 89 patients without comorbidity causing gait disturbance improved from 13.3 preoperatively to 22.9 at 2 years' follow-up. Neurogenic intermittent claudication disappeared in all cases. The patients' assessment of treatment satisfaction was "satisfied" in 74 cases, "slightly satisfied" in 12, "slightly dissatisfied" in 2, and "dissatisfied" in 1 case. In 16 cases (18%), a minimum progression of slippage occurred, but no symptomatic instability or recurrent stenosis was observed. Computed tomography showed that the lateral part of the facet joints was well preserved, and the mean residual ratio was 80%. The MFRS technique produces an adequate and safe decompression of the spinal canal, even in patients with narrow and steep facet joints in whom conventional fenestration is technically demanding.

  15. Perspective of Value-Based Management of Spinal Disorders in Brazil.

    PubMed

    Teles, Alisson R; Righesso, Orlando; Gullo, Maria Carolina R; Ghogawala, Zoher; Falavigna, Asdrubal

    2016-03-01

    The state of value-based management of spinal disorders and ongoing Brazilian strategies toward its implementation are highlighted in this article. The health care system, economic impact of spine surgery, use of patient-reported outcomes, ongoing studies about health economics, and current strategies toward implementation of quality assessment of spine care in Brazil are reviewed. During the past 20 years, there has been an increase of 226% in the number and 540% in the total cost of spine surgeries in the public health system. Examples of economic regulatory mechanisms involve the process of health technology assessment and the auditing processes imposed by health insurance companies. Some barriers to implementing clinical registries were identified from a large Latin American survey. Strategies based on education and technical support have been conducted to improve the quality of comparative-effectiveness research in spine care. Only 1 cost-utility study on spine care has been published until now. The paradigm of value-based management of spinal disorders is still incipient in Brazil. Some issues from our analysis must be emphasized: (1) Brazil presents many regional disparities and scarce resources for health care; it is crucial for the health system to allocate resources based on the value of interventions; (2) because of the high economic and social burden of developing new technologies for diagnosis and treatment, research in health economics of spine care in Brazil should be prioritized; (3) these efforts would help to provide a more accessible and effective health system for patients with spinal problems. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Arthroscopic all-inside repair for a tear of posterior root of the medial meniscus: a technical note.

    PubMed

    Choi, Nam-Hong; Son, Kyung-Mo; Victoroff, Brian N

    2008-09-01

    This technical note describes a new arthroscopic technique to repair a tear of posterior root of the medial meniscus. Cartilage at the insertion area of the posterior horn of the medial meniscus (PHMM) was removed using a curved curette inserted through an anteromedial portal. A metal anchor loaded with two FiberWires (Arthrex, Naples, FL) was placed at the insertion area of the PHMM through a high posteromedial portal. A PDS suture was passed the PHMM by curved suture hook through the anteromedial portal. Two limbs of the PDS were then used to pass two limbs of the FiberWire through the meniscus. The same procedure was repeated for the second FiberWire suture. The sutures were tied, achieving secure fixation of the posterior meniscal root at the anatomic insertion.

  17. Radiolucent cage for cervical vertebral reconstruction: a prospective study of 17 cases with 2-year minimum follow-up.

    PubMed

    Söderlund, C H; Pointillart, V; Pedram, M; Andrault, G; Vital, J M

    2004-12-01

    In cervical spondylotic myelopathy, extended anterior spinal cord decompression necessitates subsequent stable vertebral reconstruction. Reconstruction with an iliac crest graft and screw-plate fixation gives satisfactory clinical and radiological results, but they are often compromised by morbidity involving the bone harvest. The purpose of this study was to evaluate the contribution to cervical reconstruction of a biocompatible, radiolucent cage combined with screw-plate fixation, making use of bone harvested in situ. This prospective study was performed between July 2000 and March 2001 in eight women and nine men (mean age, 55 years) operated for cervical spondylotic myelopathy. Situated between levels C3 and C6, the cage was inserted after one corporectomy in ten patients, two corporectomies in five patients, and three corporectomies in two patients. The cage consisted of a polyester mesh impregnated with poly-L-lactic acid (PLLA) conferring temporary rigidity to the cage during bony fusion. Clinical and radiological follow-up (plain films, computed tomographic reconstruction in three cases) was performed at 2 months, 6 months, 12 months, 24 months and 36 months, postoperatively, with a mean follow-up of 30 months. Functional results were evaluated according to the Japanese Orthopaedic Association's scoring system. An independent surgeon assessed the radiological evidence of anterior cervical fusion using the grades proposed by Bridwell [6]. Every patient experienced neurological recovery. At last follow-up, radiological findings were consistent with grade I (complete fusion) in five cases, grade II (probable fusion) in ten cases, grade III (radiolucent halo in favor of non fusion) in one case, and grade IV (graft lysis) in one case with persistent neck pain. In three cases there was screw breakage (two grade II, one grade IV). None of these cases required surgical revision at latest follow-up. In extensive spinal cord decompression through an anterior approach, cervical reconstruction using the present type of cage can achieve clinical results comparable to conventional techniques. The rigidity of the cage meets biomechanical imperatives. Its radiolucency permits one to monitor the course of consolidation, contrary to metal cages. The cases of probable non-fusion and screw breakage were not accompanied by signs of instability on the flexion extension films. This cage meets the biologic and biomechanical imperatives of cervical reconstruction. It obviates complications involving bone harvest.

  18. Pedicle screws with a thin hydroxyapatite coating for improving fixation at the bone-implant interface in the osteoporotic spine: experimental study in a porcine model.

    PubMed

    Ohe, Makoto; Moridaira, Hiroshi; Inami, Satoshi; Takeuchi, Daisaku; Nohara, Yutaka; Taneichi, Hiroshi

    2018-03-30

    OBJECTIVE Instrumentation failure caused by the loosening of pedicle screws (PSs) in patients with osteoporosis is a serious problem after spinal surgery. The addition of a thin hydroxyapatite (HA) surface coating applied by using a sputtering process was reported recently to be a promising method for providing bone conduction around an implant without a significant risk of coating-layer breakage. In this study, the authors evaluated the biomechanical and histological features of the bone-implant interface (BII) of PSs with a thin HA coating in an in vivo porcine osteoporotic spine model. METHODS Three types of PSs (untreated/standard [STPS], sandblasted [BLPS], and HA-coated [HAPS] PSs) were implanted into the thoracic and lumbar spine (T9-L6) of 8 mature Clawn miniature pigs (6 ovariectomized [osteoporosis group] and 2 sham-operated [control group] pigs). The spines were harvested from the osteoporosis group at 0, 2, 4, 8, 12, or 24 weeks after PS placement and from the control group at 0 or 24 weeks. Their bone mineral density (BMD) was measured by peripheral quantitative CT. Histological evaluation of the BIIs was conducted by performing bone volume/tissue volume and bone surface/implant surface measurements. The strength of the BII was evaluated with extraction torque testing. RESULTS The BMD decreased significantly in the osteoporosis group (p < 0.01). HAPSs exhibited the greatest mean extraction peak torque at 8 weeks, and HAPSs and BLPSs exhibited significantly greater mean torque than the STPSs at 12 weeks (p < 0.05). The bone surface/implant surface ratio was significantly higher for HAPSs than for STPSs after 2 weeks (p < 0.05), and bonding between bone and the implant surface was maintained until 24 weeks with no detachment of the coating layer. In contrast, the bone volume/tissue volume ratio was significantly higher for HAPSs than for BLPSs or STPSs only at 4 weeks. CONCLUSIONS Using PSs with a thin HA coating applied using a sputtering process strengthens bonding at the BII, which might improve early implant fixation after spinal surgery for osteoporosis. However, the absence of increased bone mass around the screw remains a concern; prescribing osteoporosis treatment to improve bone quality might be necessary to prevent fractures around the screws.

  19. Developing a neurosurgical simulation-based educational curriculum: an overview.

    PubMed

    Harrop, James; Lobel, Darlene A; Bendok, Bernard; Sharan, Ashwini; Rezai, Ali R

    2013-10-01

    The science of medicine has undergone rapid advancement and expansion as a result of significant technological innovations, and this has affected the training of neurosurgical residents. To develop a simulation-based neurosurgical educational curriculum to improve resident education. The Congress of Neurological Surgeons established a Simulation Committee to explore the use of this technology in maximizing neurosurgical education. Simulators were incorporated into an educational curriculum with both a didactic and a technical component. The simulators and didactic portions were validated with objective pretests and posttests. The Simulator Committee has continued to expand the use of simulators in neurosurgical education and has organized several practical courses. The simulator use continues to expand into vasculature, spinal, and cranial modules. Each module has independently shown improved training scores in both didactic and technical skills. The Congress of Neurological Surgeons has successfully incorporated simulation into an educational curriculum with both didactic and technical components. This appears to be a powerful educational tool, and its uses are being further expanded.

  20. United States Air Force Graduate Student Research Program. 1989 Program Technical Report. Volume 3

    DTIC Science & Technology

    1989-12-01

    2581 Raymond Wolfe Degree: BS Scranton, Univ. of Specialty: Biology 423 Madison Ave. Assigned: School of Aerospace Medicine Scranton, PA 18510 (717...cultures were grown by incubation at 25°C under constant light conditions between 1800 and 3000 lux (or 500 and 800 uW /cm 2). The growth media used...spinal fluid immunoglobulin values of 124 HIV infected patients but otherwise asymptomatic. These values had already been obtained via lumbar puhcture. I

  1. Diagnostic imaging of child abuse

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kleinman, P.K.

    1987-01-01

    This book provides a description for all the known radiological alterations occurring in child abuse. This allows for precise interpretation of findings by radiologists. It also helps eliminate the confusion among both clinicians and non-medical personnel involved in the diagnosis, management, and legal issues related to child abuse. CONTENTS: Introduction; Skeletal trauma: general considerations; Extremity trauma; Bony thoracic trauma; Spinal trauma; Dating fractures; Visceral trauma; Head trauma; Miscellaneous forms of abuse and neglect; The postmortem examination; Differential diagnosis of child abuse; Legal considerations; Psychosocial considerations; Technical considerations and dosimetry.

  2. Prevention of cement leakage into the hip joint by a standard cement plug during PFN-A cement augmentation: a technical note.

    PubMed

    Hanke, M; Djonov, V; Tannast, M; Keel, M J; Bastian, J D

    2016-06-01

    Medial penetration of the helical blade into the hip joint after fixation of trochanteric fractures using the proximal femur nail antirotation (PFN-A) is a potential failure mode. In low demand patients a blade exchange with cement augmentation may be an option if conversion to total hip arthroplasty is unfeasible to salvage the cut-through. This article describes a technique to avoid intraarticular cement leakage using a cement plug to close the defect in the femoral head caused by the cut-through.

  3. Sciatica and claudication caused by ganglion cyst.

    PubMed

    Yang, Guang; Wen, Xiaoyu; Gong, Yubao; Yang, Chen

    2013-12-15

    Case report. We report a rare case that a ganglion cyst compressed the sciatic nerve and caused sciatica and claudication in a 51-year-old male. Sciatica and claudication commonly occurs in spinal stenosis. To our knowledge, only 4 cases have been reported on sciatica resulting from posterior ganglion cyst of hip. A 51-year-old male had a 2-month history of radiating pain on his right leg. He could only walk 20 to 30 m before stopping and standing to rest for 1 to 3 minutes. Interestingly, he was able to walk longer distances (about 200 m) when walking slowly in small steps, without any rest. He had been treated as a case of lumbar disc herniation, but conservative treatment was ineffective. On buttock examination, a round, hard, and fixative mass was palpated at the exit of the sciatic nerve. MR imaging of hip revealed a multilocular cystic mass located on the posterior aspect of the superior gemellus and obturator internus, compressing the sciatic nerve. On operation, we found that the cyst extended to the superior gemellus and the obturator internus, positioned right at the outlet of the sciatic nerve. At 18 months of follow-up, the patient continued to be symptom free. He returned to comprehensive physical activity with no limitations. For an extraspinal source, a direct compression on the sciatic nerve also resulted in sciatica and claudication. A meticulous physical examination is very important for the differential diagnosis of extraspinal sciatica from spinal sciatica.

  4. Percutaneous computer-assisted translaminar facet screw: an initial human cadaveric study.

    PubMed

    Sasso, Rick C; Best, Natalie M; Potts, Eric A

    2005-01-01

    Translaminar facet screws are a minimally invasive technique for posterior lumbar fixation with good success rates. Computer-assisted image navigation using virtual fluoroscopy allows multiple simultaneous screens in various planes to plan and drive spinal instrumentation. This study evaluates the percutaneous placement of translaminar facet screws with the use of virtual fluoroscopy as an image guidance technique. A human cadaveric study was performed with a percutaneous reference frame applied to the iliac crest. Ten translaminar facet screws were placed bilaterally at five levels. Anteroposterior and lateral images were used to navigate 4.0-mm screws through a percutaneous portal under virtual fluoroscopy. An axial computed tomographic scan through the instrumented levels was obtained after the screws were placed. Screws were graded on entry, course through the lamina, and terminus. A grading system was devised to grade the course through the lamina. All 10 screw-entry points were judged optimal at the spinous process laminar junction. There were five Grade I breeches with less than 1/2 the screw through the lamina, and five Grade 0 screw placements with the screw contained completely within the lamina. The termination point was acceptable in five screws. The screws that began on the right and terminated on the left were all found to have grade II breakouts. No screws placed the spinal canal or exiting nerve root at risk. Virtual fluoroscopy provides significant assistance in percutaneous placement of translaminar facet screws and results in safe position of entry, lamina course, and terminus.

  5. Posterior reversible encephalopathy syndrome with status epilepticus following surgery for lumbar stenosis and spondylolisthesis: case report.

    PubMed

    Delgado-López, Pedro David; Garcés-Pérez, Gloria; García-Carrasco, Juan; Alonso-García, Esther; Gómez-Menéndez, Ana Isabel; Martín-Alonso, Javier

    2018-06-01

    Posterior reversible encephalopathy syndrome (PRES) is a clinicoradiological condition encountered in many different clinical settings, generally occurring in the context of hypertensive crisis, immunosuppressive therapy or autoimmune diseases. It is characterized by headache, stupor, seizures and visual alterations. MRI findings include white matter changes preferentially in the parieto-occipital regions. Although pathogenesis is not fully elucidated, vasoconstriction and brain hypoperfusion seem to be the cause of brain ischemia and vasogenic edema. CSF hypotension is also a reported plausible pathogenic mechanism. We present a unique case of PRES following laminectomy and fixation for L4-5 lumbar stenosis and spondylolisthesis. The patient presented with a 5-day duration status epilepticus immediately after surgery. Brain MRI showed FLAIR and T2 hyperintensities in the bilateral parietal and occipital lobes and external capsules. On the basis of her postoperative lumbar images, we hypothesize that an unnoticed CSF leak might have contributed to develop PRES in this case. The patient developed multiple postoperative complications. Following treatment for severe hypertension and seizures she ultimately recovered. Prompt recognition and treatment of this potentially life-threatening syndrome is necessary in order to increase the likelihood of favorable outcome. Spinal surgeons need to be aware of the possibility of neurological deterioration following spinal surgery and be alert about the occurrence of a dural leak, either recognized or unnoticed, as the plausible mechanism triggering PRES. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Treatment effect, postoperative complications, and their reasons in juvenile thoracic and lumbar spinal tuberculosis surgery.

    PubMed

    He, Qing-Yi; Xu, Jian-Zhong; Zhou, Qiang; Luo, Fei; Hou, Tianyong; Zhang, Zehua

    2015-10-01

    Fifty-four juvenile cases under 18 years of age with thoracic and lumbar spinal tuberculosis underwent focus debridement, deformity correction, bone graft fusion, and internal fixation. The treatment effects, complications, and reasons were analyzed retrospectively. There were 54 juvenile cases under 18 years of age with thoracolumbar spinal tuberculosis. The average age was 9.2 years old, and the sample comprised 38 males and 16 females. The disease types included 28 thoracic cases, 17 thoracolumbar cases, and 9 lumbar cases. Nerve function was evaluated with the Frankel classification. Thirty-six cases were performed with focus debridement and deformity correction and were supported with allograft or autograft in mesh and fixed with pedicle screws from a posterior approach. Eight cases underwent a combined anterior and posterior surgical approach. Nine cases underwent osteotomy and deformity correction, and one case received focus debridement. The treatment effects, complications, and bone fusions were tracked for an average of 52 months. According to the Frankel classification, paralysis was improved from 3 cases of B, 8 cases of C, 18 cases of D, and 25 cases of E preoperatively. This improvement was found in 3 cases of C, 6 cases of D, and 45 cases of E at a final follow-up postoperatively. No nerve dysfunction was aggravated. VAS was improved from 7.8 ± 1.7 preoperatively to 3.2 ± 2.1 at final follow-up postoperatively. ODI was improved from 77.5 ± 17.3 preoperatively to 28.4 ± 15.9 at final follow-up postoperatively. Kyphosis Cobb angle improved from 62.2° ± 3.7° preoperatively to 37° ± 2.4° at final follow-up postoperatively. Both of these are significant improvements, and all bone grafts were fused. Complications related to the operation occurred in 31.5% (17/54) of cases. Six cases suffered postoperative aggravated kyphosis deformity, eight cases suffered proximal kyphosis deformity, one case suffered pedicle penetration, one case suffered failure of internal devices, and one case suffered recurrence of tuberculosis. As long as the treatment plan is fully prepared, the surgical option can achieve a satisfactory curative effect in treating juvenile spinal tuberculosis despite some complications.

  7. Lumbar spinal fusion. Outcome in relation to surgical methods, choice of implant and postoperative rehabilitation.

    PubMed

    Christensen, Finn Bjarke

    2004-10-01

    Chronic low back pain (CLBP) has become one of the most common causes of disability in adults under 45 years of age and is consequently one of the most common reasons for early retirement in industrialised societies. Accordingly, CLBP represents an expensive drain on society's resources and is a very challenging area for which a consensus for rational therapy is yet to be established. The spinal fusion procedure was introduced as a treatment option for CLBP more than 70 years ago. However, few areas of spinal surgery have caused so much controversy as spinal fusion. The literature reveals divergent opinions about when fusion is indicated and how it should be performed. Furthermore, the significance of the role of postoperative rehabilitation following spinal fusion may be underestimated. There exists no consensus on the design of a program specific for rehabilitation. Ideally, for any given surgical procedure, it should be possible to identify not only possible complications relative to a surgical procedure, but also what symptoms may be expected, and what pain behaviour may be expected of a particular patient. The overall aims of the current studies were: 1) to introduce patient-based functional outcome evaluation into spinal fusion treatment; 2) to evaluate radiological assessment of different spinal fusion procedures; 3) to investigate the effect of titanium versus stainless steel pedicle screws on mechanical fixation and bone ingrowth in lumbar spinal fusion; 4) to analyse the clinical and radiological outcome of different lumbar spinal fusion techniques; 5) to evaluate complications and re-operation rates following different surgical procedures; and 6) to analyse the effect of different rehabilitation strategies for lumbar spinal fusion patients. The present thesis comprises 9 studies: 2 clinical retrospective studies, 1 clinical prospective case/reference study, 5 clinical randomised prospective studies and 1 animal study (Mini-pigs). In total, 594 patients were included in the investigation from 1979 to 1999. Each had prior to inclusion at least 2 years of CLBP and had therefore been subjected to most of the conservative treatment leg pain, due to localized isthmic spondylolisthesis grades I-II or primary or secondary degeneration. PATIENT-BASED FUNCTIONAL OUTCOME: Patients' self-reported parameters should include the impact of CLBP on daily activity, work and leisure time activities, anxiety/depression, social interests and intensity of back and leg pain. Between 1993 and 2003 approximately 1400 lumbar spinal fusion patients completed the Dallas Pain Questionnaire under prospective design studies. In 1996, the Low Back Pain Rating scale was added to the standard questionnaire packet distributed among spinal fusion patients. In our experience, these tools are valid instruments for clinical assessment of candidates for spinal fusion procedures. It is extremely difficult to interpret radiographs of both lumbar posterolateral fusion and anterior interbody fusion. Plain radiographs are clearly not the perfect media for analysis of spinal fusion, but until new and better diagnostic methods are available for clinical use, radiographs will remain the golden standard. Therefore, the development of a detailed reliable radiographic classification system is highly desirable. The classification used in the present thesis for the evaluation of posteroalteral spinal fusion, both with and without instrumentation, demonstrated good interobserver and intraobserver agreement. The classification showed acceptable reliability and may be one way to improve interstudy and intrastudy correlation of radiologic outcomes after posterolateral spinal fusion. Radiology-based evaluation of anterior lumbar interbody fusion is further complicated when cages are employed. The use of different cage designs and materials makes it almost impossible to establish a standard radiological classification system for anterior fusions. BONE-SCREW INTERFACE: Mechanical binding at the bone-screw interface was significantly greater for titanium pedicle screws than it was for stainless steel. This could be explained by the fact that the titanium screws had superior bone on-growth. There was no correlation between screw removal torques and pull-out strength. Clinically, the use of titanium and titanium-alloy pedicle screws may be preferable for osteoporotic patients and those with decreased osteogenesis. The present series of studies observed significant long-term functional improvement for approximately 70% of patients who had undergone lumbar spinal fusion procedure. Solid fusion as determined from radiographs ranged from 52% to 92% depending on the choice of surgical procedure. The choice of surgical procedure should relate to the diagnosis, as patients with isthmic spondylolisthesis (Grades I and II) are best served with posterolateral fusion without instrumentation, and patients with disc degeneration seem to gain most from instrumented posterolateral fusion or circumferential fusion. The number of perioperative complications increased with the use of pedicle screw systems to support posterolateral fusions and increased further with the use of circumferential fusions. There was no significant association between outcome result and perioperative complications. The risk of reoperation within 2 years after the spinal fusion procedure was, however, significantly lower for those who had received circumferential fusion in comparison to posterolateral fusion with instrumentation. Furthermore, the risk of non-union was found to be significantly lower for patients who had received circumferential fusion as compared to posterolateral fusion with and without instrumentation. The complications of sexual dysfunction and fusion at non-intended levels were found to be significant but without influence on the overall outcome. The patients in the Back-café group performed a succession of many daily tasks significantly better and moreover had less pain compared with both the Video and Training groups 2 years after lumbar spinal fusion. The Video group had significantly greater treatment demands outside the hospital system. This study demonstrates the importance of the inclusion of coping schemes and questions the role of intensive exercises in a rehabilitation program for spinal fusion patients.

  8. Phenotypic heterogeneity in metabolic traits among single cells of a rare bacterial species in its natural environment quantified with a combination of flow cell sorting and NanoSIMS

    PubMed Central

    Zimmermann, Matthias; Escrig, Stéphane; Hübschmann, Thomas; Kirf, Mathias K.; Brand, Andreas; Inglis, R. Fredrik; Musat, Niculina; Müller, Susann; Meibom, Anders; Ackermann, Martin; Schreiber, Frank

    2015-01-01

    Populations of genetically identical microorganisms residing in the same environment can display marked variability in their phenotypic traits; this phenomenon is termed phenotypic heterogeneity. The relevance of such heterogeneity in natural habitats is unknown, because phenotypic characterization of a sufficient number of single cells of the same species in complex microbial communities is technically difficult. We report a procedure that allows to measure phenotypic heterogeneity in bacterial populations from natural environments, and use it to analyze N2 and CO2 fixation of single cells of the green sulfur bacterium Chlorobium phaeobacteroides from the meromictic lake Lago di Cadagno. We incubated lake water with 15N2 and 13CO2 under in situ conditions with and without NH4+. Subsequently, we used flow cell sorting with auto-fluorescence gating based on a pure culture isolate to concentrate C. phaeobacteroides from its natural abundance of 0.2% to now 26.5% of total bacteria. C. phaeobacteroides cells were identified using catalyzed-reporter deposition fluorescence in situ hybridization (CARD-FISH) targeting the 16S rRNA in the sorted population with a species-specific probe. In a last step, we used nanometer-scale secondary ion mass spectrometry to measure the incorporation 15N and 13C stable isotopes in more than 252 cells. We found that C. phaeobacteroides fixes N2 in the absence of NH4+, but not in the presence of NH4+ as has previously been suggested. N2 and CO2 fixation were heterogeneous among cells and positively correlated indicating that N2 and CO2 fixation activity interact and positively facilitate each other in individual cells. However, because CARD-FISH identification cannot detect genetic variability among cells of the same species, we cannot exclude genetic variability as a source for phenotypic heterogeneity in this natural population. Our study demonstrates the technical feasibility of measuring phenotypic heterogeneity in a rare bacterial species in its natural habitat, thus opening the door to study the occurrence and relevance of phenotypic heterogeneity in nature. PMID:25932020

  9. Distal radius fracture fixation with a volar locking plate and endoscopic carpal tunnel release using a single 15mm approach: Feasibility study.

    PubMed

    Zemirline, A; Taleb, C; Naito, K; Vernet, P; Liverneaux, P; Lebailly, F

    2018-05-17

    Distal radius fractures (DRF) may trigger, reveal or decompensate acute carpal tunnel syndrome (CTS) in 0.5-21% of cases. Internal fixation and median nerve release must then be carried out urgently. Less invasive approaches have been described for both the median nerve release using an endoscopic device and for the DRF fixation using a volar locking plate. We assessed the feasibility of DRF fixation and median nerve release through a single, minimally-invasive 15mm approach on a series of 10 cases. We reviewed retrospectively 10 consecutive cases of DRF associated with symptomatic CTS in 8 women and 2 men, aged 57 years on average. CTS was diagnosed clinically. All patients were treated during outpatient surgery with a volar locking plate and endoscopic carpal tunnel release using a single 15mm minimally-invasive approach. In one case, arthroscopic scapholunate repair was also required. Six months after the procedure, all patients were reviewed with a clinical examination and a radiological evaluation. The average values for the clinical and radiological outcomes were as follows: pain on VAS 1.5/10; QuickDASH 14.3/100; flexion 90%; extension 90.6%; pronation 95.6%; supination 87.9%; grip strength 90.1%; 2PD test 5.2mm (4-8mm). Five complications occurred: two cases of temporary dysesthesia in the territory of the median nerve and one case of temporary hypoesthesia of the palmar branch of the median nerve, which had all completely recovered; two cases of complex regional pain syndrome type I, which were still active at 6 months. Despite its methodological weaknesses, our study is the only one to describe the technical feasibility of a single 15mm minimally-invasive approach for both internal fixation using a volar locking plate and endoscopic nerve release, with no serious complications. This technique should be added to the surgical toolbox of minimally-invasive procedures for the hand and wrist. Copyright © 2018 SFCM. Published by Elsevier Masson SAS. All rights reserved.

  10. Technical Advances in Intracellular Detection Using Immuno-Gold Particles: Simple Cryofixation with Metal Contact Quick Freezing.

    PubMed

    Song, Chihong; Lee, Ju Huck; Jun, Sangmi; Chung, Jeong Min; Hyun, Jaekyung; Jung, Hyun Suk

    2016-05-01

    The preparation of biological specimens using cryofixation techniques ensures excellent visibility of intracellular structures and preserves the antigenic sites of subcellular molecules. Hence, cryofixation is an effective method of preparing samples for analyses using antibodies conjugated to gold nanoparticles that are designed to detect the localization of specific target molecules within cells. However, cryofixation cannot be utilized easily because it requires expensive equipment and skilled technologists, resulting in a high level of expense for researchers. Here, we describe a simple technical approach to cryofixation that uses metal contact quick freezing followed by a modified freeze substitution technique and immuno-gold labeling electron microscopy. Micrograph images of cells prepared using this modified cryofixation method demonstrated its superiority over chemical fixation for high contrast visualization of the morphologies of cellular components and preservation of antigenicity for immuno-gold labeling. This report provides valuable technical information related to the advancement of metal contact quick freezing techniques, which can be used to visualize biomedical events of interest in an easy, simple, and rapid manner.

  11. Scaffold Translation: Barriers Between Concept and Clinic

    PubMed Central

    Murphy, William L.

    2011-01-01

    Translation of scaffold-based bone tissue engineering (BTE) therapies to clinical use remains, bluntly, a failure. This dearth of translated tissue engineering therapies (including scaffolds) remains despite 25 years of research, research funding totaling hundreds of millions of dollars, over 12,000 papers on BTE and over 2000 papers on BTE scaffolds alone in the past 10 years (PubMed search). Enabling scaffold translation requires first an understanding of the challenges, and second, addressing the complete range of these challenges. There are the obvious technical challenges of designing, manufacturing, and functionalizing scaffolds to fill the Form, Fixation, Function, and Formation needs of bone defect repair. However, these technical solutions should be targeted to specific clinical indications (e.g., mandibular defects, spine fusion, long bone defects, etc.). Further, technical solutions should also address business challenges, including the need to obtain regulatory approval, meet specific market needs, and obtain private investment to develop products, again for specific clinical indications. Finally, these business and technical challenges present a much different model than the typical research paradigm, presenting the field with philosophical challenges in terms of publishing and funding priorities that should be addressed as well. In this article, we review in detail the technical, business, and philosophical barriers of translating scaffolds from Concept to Clinic. We argue that envisioning and engineering scaffolds as modular systems with a sliding scale of complexity offers the best path to addressing these translational challenges. PMID:21902613

  12. Novel Method for Analyzing Locomotor Ability after Spinal Cord Injury in Rats: Technical Note

    PubMed Central

    Shinozaki, Munehisa; Yasuda, Akimasa; Nori, Satoshi; Saito, Nobuhito; Toyama, Yoshiaki; Okano, Hideyuki; Nakamura, Masaya

    2013-01-01

    In the research for the treatment of spinal cord injury (SCI), the evaluation of motor function in model rats must be as objective, noninvasive, and ethical as possible. The maximum speed and acceleration of a mouse measured using a SCANET system were previously reported to vary significantly according to severity of SCI. In the present study, the motor performance of SCI model rats was examined with SCANET and assessed for Basso-Beattie-Bresnahan (BBB) score to determine the usefulness of the SCANET system in evaluating functional recovery after SCI. Maximum speed and acceleration within the measurement period correlated significantly with BBB scores. Furthermore, among several phased kinematic factors used in BBB scores, the capability of “plantar stepping” was associated with a drastic increase in maximum speed and acceleration after SCI. Therefore, evaluation of maximum speed and acceleration using a SCANET system is a useful method for rat models of SCI and can complement open field scoring scales. PMID:24097095

  13. Meeting the privacy requirements for the development of a multi-centre patient registry in Canada: the Rick Hansen Spinal Cord Injury Registry.

    PubMed

    Noonan, Vanessa K; Thorogood, Nancy P; Joshi, Phalgun B; Fehlings, Michael G; Craven, B Catharine; Linassi, Gary; Fourney, Daryl R; Kwon, Brian K; Bailey, Christopher S; Tsai, Eve C; Drew, Brian M; Ahn, Henry; Tsui, Deborah; Dvorak, Marcel F

    2013-05-01

    Privacy legislation addresses concerns regarding the privacy of personal information; however, its interpretation by research ethics boards has resulted in significant challenges to the collection, management, use and disclosure of personal health information for multi-centre research studies. This paper describes the strategy used to develop the national Rick Hansen Spinal Cord Injury Registry (RHSCIR) in accordance with privacy statutes and benchmarked against best practices. An analysis of the regional and national privacy legislation was conducted to determine the requirements for each of the 31 local RHSCIR sites and the national RHSCIR office. A national privacy and security framework was created for RHSCIR that includes a governance structure, standard operating procedures, training processes, physical and technical security and privacy impact assessments. The framework meets a high-water mark in ensuring privacy and security of personal health information nationally and may assist in the development of other national or international research initiatives. Copyright © 2013 Longwoods Publishing.

  14. Meeting the Privacy Requirements for the Development of a Multi-Centre Patient Registry in Canada: The Rick Hansen Spinal Cord Injury Registry

    PubMed Central

    Noonan, Vanessa K.; Thorogood, Nancy P.; Joshi, Phalgun B.; Fehlings, Michael G.; Craven, B. Catharine; Linassi, Gary; Fourney, Daryl R.; Kwon, Brian K.; Bailey, Christopher S.; Tsai, Eve C.; Drew, Brian M.; Ahn, Henry; Tsui, Deborah; Dvorak, Marcel F.

    2013-01-01

    Privacy legislation addresses concerns regarding the privacy of personal information; however, its interpretation by research ethics boards has resulted in significant challenges to the collection, management, use and disclosure of personal health information for multi-centre research studies. This paper describes the strategy used to develop the national Rick Hansen Spinal Cord Injury Registry (RHSCIR) in accordance with privacy statutes and benchmarked against best practices. An analysis of the regional and national privacy legislation was conducted to determine the requirements for each of the 31 local RHSCIR sites and the national RHSCIR office. A national privacy and security framework was created for RHSCIR that includes a governance structure, standard operating procedures, training processes, physical and technical security and privacy impact assessments. The framework meets a high-water mark in ensuring privacy and security of personal health information nationally and may assist in the development of other national or international research initiatives. PMID:23968640

  15. Variables affecting the quantitation of CD22 in neoplastic B cells.

    PubMed

    Jasper, Gregory A; Arun, Indu; Venzon, David; Kreitman, Robert J; Wayne, Alan S; Yuan, Constance M; Marti, Gerald E; Stetler-Stevenson, Maryalice

    2011-03-01

    Quantitative flow cytometry (QFCM) is being applied in the clinical flow cytometry laboratory for diagnosis, prognosis, and assessment of patients receiving antibody-based therapy. ABC values and the effect of technical variables on CD22 quantitation in acute lymphoblastic leukemia (ALL), chronic lymphocytic leukemia (CLL), mantle cell lymphoma (MCL), follicular lymphoma (FCL), hairy cell leukemia (HCL) and normal B cells were studied. The QuantiBrite System® was used to determine the level of CD22 expression (mean antibody bound per cell, ABC) by malignant and normal B cells. The intra-assay variability, number of cells required for precision, effect of delayed processing as well as shipment of peripheral blood specimens (delayed processing and exposure to noncontrolled environments), and the effect of paraformaldehyde fixation on assay results were studied. The QuantiBRITE method of measuring CD22 ABC is precise (median CV 1.6%, 95% confidence interval, 1.2-2.3%) but a threshold of 250 malignant cells is required for reliable CD22 ABC values. Delayed processing and overnight shipment of specimens resulted in significantly different ABC values whereas fixation for up to 12 h had no significant effect. ABC measurements determined that CD22 expression is lower than normal in ALL, CLL, FCL, and MCL but higher than normal in HCL. CD22 expression was atypical in the hematolymphoid malignancies studied and may have diagnostic utility. Technical variables such as cell number analyzed and delayed processing or overnight shipment of specimens impact significantly on the measurement of antigen expression by QFCM in the clinical laboratory. Published 2010 Wiley-Liss, Inc.

  16. Postoperative magnetic resonance imaging artifact with cobalt-chromium versus titanium spinal instrumentation: presented at the 2013 Joint Spine Section Meeting. Clinical article.

    PubMed

    Ahmad, Faiz U; Sidani, Charif; Fourzali, Roberto; Wang, Michael Y

    2013-11-01

    Cobalt-chromium alloy (CoCr) rods haves some preferred biomechanical properties over titanium rods for spinal fixation. The use of CoCr rods in spinal fusion is relatively new, and there is no study in the existing world literature assessing the artifact caused by these rods in patients undergoing postoperative MRI. The purpose of this study is to compare the amount of imaging artifact caused by these implants and to assess its impact on the visualization of neighboring neural structures. This study investigated MR images in patients who underwent implantation of thoracolumbar instrumentation using 5.5-mm-diameter CoCr rods between November 2009 and March 2011 and images obtained in a comparison group of patients who had 5.5-mm titanium rods implanted during the same time period. Axial measurements of the artifact created by the rods between the screw heads were compared between the groups. Two blinded board-certified radiologists performed the measurements independently. They scored the visualization of the spinal canal using a subjective scoring system of 1-3, with 1 representing very good visualization and 2 and 3 representing reduced (good or suboptimal, respectively) visualization as a result of rod-related artifact. All measurements and scores were independently provided for T1-weighted and T2-weighted fast spin echo sequences (1.5-T magnet, 5-mm slice thickness). A total of 40 levels from the CoCr group (6 patients) and 30 levels from the titanium group (9 patients) were included in the analysis. Visualization of the canal at all levels was rated a score of 1 (very good) by both evaluators for both the CoCr and titanium groups. The average artifact on T1-weighted images measured 11.8 ± 1.8 mm for the CoCr group and 8.5 ± 1.2 mm for the titanium group (p < 0.01). The corresponding measurements on T2-weighted images were 11.0 ± 2.3 mm and 8.3 ± 1.7 mm (p < 0.01), respectively. In a mixed regression model, the mean artifact measurement for the CoCr group was, on average, 3.5 mm larger than for the control group. There was no significant difference between the measurements of the 2 evaluators (p = 0.99). The artifact caused by CoCr rods is approximately 3.5 mm larger than that caused by titanium rods on axial T1- and T2-weighted MRI. However, artifact from either CoCr or titanium was not found to interfere with the evaluation of the spinal canal and surrounding neural elements.

  17. Improved Bone Graft Method for Upper Cervical Surgery with Posterior Approach: Technical Description and Report of 52 Cases.

    PubMed

    Wang, Yong-Li; Wang, Xiang-Yang

    2018-06-01

    We sought to report a minimum 12 months' follow-up results of our improved bone graft method for upper cervical surgery with the posterior approach. Among 52 consecutive cases, odontoid nonunion occurred in 33 patients, atlantoaxial instability in 11 patients, and occipitocervical deformity in 8 patients who underwent posterior C1-C2 transarticular screw/screw-rod internal fixation (41 cases) and occipitocervical fusion (11 cases) with the improved bone graft technique. Each surgical procedure was performed by the same senior spine surgeon. We took lateral cervical standing roentgenograms before surgery and immediately after surgery. Then we conducted craniocerebral computed tomography examination with reconstruction at 3, 6, 12, and 24 months and annually thereafter. The postoperative follow-up times are about 12-38 months. All cases showed satisfactory screw fixation by radiographic examination, and there were no postoperative neurologic complications. One case had postoperative retropharyngeal infection after the transoral release and posterior reduction by pedicle screw instrumentation. All patients got solid fusions, and no pseudarthrosis occurred. All cases had solid fusions at the 3-month follow-up. Good bone graft bed, enough bone graft material, solid local fixation, and effective bone graft method are prerequisites for a successful bone graft. By analyzing postoperative follow-up in the consecutive cases in this study, our bone graft method describing a new bone graft structure is a reliable posterior fusion technique. It is worth considering, and further research is needed. Copyright © 2018. Published by Elsevier Inc.

  18. Occipitocervical fusions in children. Retrospective analysis and technical considerations.

    PubMed

    Rodgers, W B; Coran, D L; Emans, J B; Hresko, M T; Hall, J E

    1999-07-01

    This report presents a retrospective analysis of the authors' experience with occipitocervical fusions in children and adolescents during the last 2 decades. A description of an operative technique devised by the senior author (JEH), and a comparison of the results using this and other methods of fusion are given. Twenty-three patients underwent occipitocervical fusion. Fifteen of the patients were operated on using the authors' technique. To achieve stable fixation of the distal cervical vertebra a threaded Kirschner wire was passed transversely through the spinous process; occipital fixation was achieved by the traditional method of wiring corticocancellous bone graft to the skull through burr holes. The occipital wires then were wrapped around the Kirschner wire and the graft was cradled in the resulting nest. Halo immobilization was used in 10 patients for an average of 12.5 weeks (range, 6-24 weeks). Twenty-two patients achieved successful fusion at an average followup of 5.8 years (range, 1-14.33 years). Several complications, including transient quadriplegia in one patient, pseudarthrosis in two (one of which persists), hardware fixation failure in one, unintended distal extension of the fusion, pneumonia, wound infection, halo pin infection, skin breakdown under the halo vest, hydrocephalus, cerebrospinal fluid leak, and traumatic fusion fracture were encountered. Results using the technique described herein are comparable with or better than the results reported in the previous literature, and the results of the patients in this series in whom the technique was not used.

  19. Spinal fusion for scoliosis in Rett syndrome with an emphasis on early postoperative complications.

    PubMed

    Gabos, Peter G; Inan, Muharrem; Thacker, Mihir; Borkhu, Buttugs

    2012-01-15

    Retrospective case-control study. To examine the postoperative complications of posterior spinal fusion in a population of patients with Rett syndrome (RS). Scoliosis is a common feature of RS, a progressive neurologic disorder affecting almost exclusively females. Despite this, there is little published information regarding the surgical treatment of scoliosis in this disorder. Sixteen consecutive female patients with RS treated by posterior spinal fusion and unit rod instrumentation for progressive scoliosis between 1995 and 2003 were evaluated. Only patients with a minimum of 2-year follow-up were included. Preoperative medical conditions and postoperative complications were recorded. As a control group, we randomly selected 32 spastic quadriplegic patients who underwent the identical procedure during the same time period, selected from our database and matched according to age, level of neurologic impairment, and medical complexity. There was a high rate of early medical complications in the RS patients, with 28 major and 37 minor complications. Only 1 patient did not have a major medical complication, and every patient had at least 1 minor gastrointestinal and/or respiratory complication. Major respiratory complications occurred in 10 patients (63%) and comprised 61% of all major complications. Major gastrointestinal complications occurred in 6 patients (37%) and comprised 21% of all major complications. Other major complications included disseminated intravascular coagulopathy (1 patient), subacute bacterial endocarditis (1 patient), sacral decubiti requiring surgical debridement (2 patients), and extensive bilateral heterotopic ossification of the hips (1 patient). There were no cases of instrumentation failure, pseudarthrosis, deep infection, or need for rod revision. Postoperative complication scores were similar to those in patients with spastic quadriplegic pattern cerebral palsy. Spinal fusion for scoliosis in RS can give a satisfactory technical result, but a high rate of early postoperative medical problems should be anticipated.

  20. [TECHNIQUES IN MITRAL VALVE REPAIR VIA A MINIMALLY INVASIVE APPROACH].

    PubMed

    Ito, Toshiaki

    2016-03-01

    In mitral valve repair via a minimally invasive approach, resection of the leaflet is technically demanding compared with that in the standard approach. For resection and suture repair of the posterior leaflet, premarking of incision lines is recommended for precise resection. As an alternative to resection and suture, the leaflet-folding technique is also recommended. For correction of prolapse of the anterior leaflet, neochordae placement with the loop technique is easy to perform. Premeasurement with transesophageal echocardiography or intraoperative measurement using a replica of artificial chordae is useful to determine the appropriate length of the loops. Fine-tuning of the length of neochordae is possible by adding a secondary fixation point on the leaflet if the loop is too long. If the loop is too short, a CV5 Gore-Tex suture can be passed through the loop and loosely tied several times to stack the knots, with subsequent fixation to the edge of the leaflet. Finally, skill in the mitral valve replacement technique is necessary as a back-up for surgeons who perform minimally invasive mitral valve repair.

  1. Bone augmentation in dental implantology using press-fit bone cylinders and twin-principle diamond hollow drills: a case series.

    PubMed

    Draenert, Florian Guy; Huetzen, Dominic; Kämmerer, Peer; Wagner, Wilfried

    2011-09-01

    Bone transplants are mostly prepared with cutting drills, chisels, and rasps. These techniques are difficult for unexperienced surgeons, and the implant interface is less precise due to unstandardized preparation. Cylindrical bone transplants are a known alternative. Current techniques include fixation methods with osteosynthesis screws or the dental implant. A new bone cylinder transplant technique is presented using a twin-drill principle resulting in a customized pressfit of the transplant without fixation devices and combining this with the superior grinding properties of a diamond coating. New cylindrical diamond hollow drills are used for customized press fit bone transplants in a case series of five patients for socket reconstruction in the front and molar region of maxilla and mandibula with and without simultaneous implant placement. The technical approach was successful without intra or postoperative complications during the acute healing phase. The customized press fit completes a technological trias of bone cylinder transplant techniques adding to the assisted press fit with either osteosynthesis screws or the dental implant itself. © 2009 Wiley Periodicals, Inc.

  2. Intraoperative reduction of the scapular body--a technical trick.

    PubMed

    Bartonícek, Jan; Fric, Vladimír; Tucek, Michal

    2009-04-01

    When internal fixation of the scapular neck and body fractures is performed, a problem may occur with reduction and retention of position of the lateral border of the scapula during surgery. For this purpose, the authors have developed their own technique of stabilization using a K-wire in a novel way. The technique is indicated in a 2-part shear unstable fracture of the lateral border. It cannot be used in fractures with an intercalated segment. A 2.5-mm drill bit is used to drill a 1.5-cm deep hole into the "medullary cavity" of each of the 2 fragments of the lateral border. A K-wire, 1.5 mm in diameter and 2.5-cm long, is inserted into the distal fragment. The protruding end of the K-wire is inserted into the hole in the proximal fragment. This intramedullary peg helps to maintain reduction and keeps both fragments stable. Subsequently, the lateral border is stabilized with a 3.5-mm reconstruction plate. This technique is quite simple and allows for a temporary stabilization of fragments without compromising the subsequent fixation by plate screws.

  3. Is Polymethyl Methacrylate a Viable Option for Salvaging Lateral Mass Screw Failure in the Subaxial Cervical Spine?

    PubMed Central

    Gallizzi, Michael A.; Kuhns, Craig A.; Jenkins, Tyler J.; Pfeiffer, Ferris M.

    2014-01-01

    Study Design Biomechanical analysis of lateral mass screw pullout strength. Objective We compare the pullout strength of our bone cement–revised lateral mass screw with the standard lateral mass screw. Methods In cadaveric cervical spines, we simulated lateral mass screw “cutouts” unilaterally from C3 to C7. We salvaged fixation in the cutout side with polymethyl methacrylate (PMMA) or Cortoss cement (Orthovita, Malvern, Pennsylvania, United States), allowed the cement to harden, and then drilled and placed lateral mass screws back into the cement-augmented lateral masses. On the contralateral side, we placed standard lateral mass screws into the native, or normal lateral, masses and then compared pullout strength of the cement-augmented side to the standard lateral mass screw. For pullout testing, each augmentation group was fixed to a servohydraulic load frame and a specially designed pullout fixture was attached to each lateral mass screw head. Results Quick-mix PMMA-salvaged lateral mass screws required greater force to fail when compared with native lateral mass screws. Cortoss cement and PMMA standard-mix cement-augmented screws demonstrated less strength of fixation when compared with control-side lateral mass screws. Attempts at a second round of cement salvage of the same lateral masses led to more variations in load to failure, but quick-mix PMMA again demonstrated greater load to failure when compared with the nonaugmented control lateral mass screws. Conclusion Quick-mix PMMA cement revision equips the spinal surgeon with a much needed salvage option for a failed lateral mass screw in the subaxial cervical spine. PMID:25649421

  4. A study to compare the efficacy of polyether ether ketone rod device with titanium devices in posterior spinal fusion in a canine model.

    PubMed

    Wang, Nanxiang; Xie, Huanxin; Xi, Chunyang; Zhang, Han; Yan, Jinglong

    2017-03-09

    The benefits of posterior lumbar fusion surgery with orthotopic paraspinal muscle-pediculated bone flaps are well established. However, the problem of non-union due to mechanical support is not completely resolved. The aim of the study was to compare the efficacy of polyether ether ketone (PEEK) rod device with conventional titanium devices in the posterior lumbar fusion surgery with orthotopic paraspinal muscle-pediculated bone flaps. This was a randomized controlled study with an experimental animal model. Thirty-two mongrel dogs were randomly divided into two groups-control group (n = 16), which received the titanium device and the treatment group (n = 16), which received PEEK rods. The animals were sacrificed 8 or 16 weeks after surgery. Lumbar spines of dogs in both groups were removed, harvested, and assessed for radiographic, biomechanical, and histological changes. Results in the current study indicated that there was no significant difference in the lumbar spine of the control and treatment groups in terms of radiographic, manual palpation, and gross examination. However, certain parameters of biomechanical testing showed significant differences (p < 0.05) in stiffness and displacement, revealing a better fusion (treatment group showed decreased stiffness with decreased displacement) of the bone graft. Similarly, the histological analysis also revealed a significant fusion mass in both treatment and control groups (p < 0.05). These findings revealed that fixation using PEEK connecting rod could improve the union of the bone graft in the posterior lumbar spine fusion surgery compared with that of the titanium rod fixation.

  5. Risk factors for acute surgical site infections after lumbar surgery: a retrospective study.

    PubMed

    Lai, Qi; Song, Quanwei; Guo, Runsheng; Bi, Haidi; Liu, Xuqiang; Yu, Xiaolong; Zhu, Jianghao; Dai, Min; Zhang, Bin

    2017-07-19

    Currently, many scholars are concerned about the treatment of postoperative infection; however, few have completed multivariate analyses to determine factors that contribute to the risk of infection. Therefore, we conducted a multivariate analysis of a retrospectively collected database to analyze the risk factors for acute surgical site infection following lumbar surgery, including fracture fixation, lumbar fusion, and minimally invasive lumbar surgery. We retrospectively reviewed data from patients who underwent lumbar surgery between 2014 and 2016, including lumbar fusion, internal fracture fixation, and minimally invasive surgery in our hospital's spinal surgery unit. Patient demographics, procedures, and wound infection rates were analyzed using descriptive statistics, and risk factors were analyzed using logistic regression analyses. Twenty-six patients (2.81%) experienced acute surgical site infection following lumbar surgery in our study. The patients' mean body mass index, smoking history, operative time, blood loss, draining time, and drainage volume in the acute surgical site infection group were significantly different from those in the non-acute surgical site infection group (p < 0.05). Additionally, diabetes mellitus, chronic obstructive pulmonary disease, osteoporosis, preoperative antibiotics, type of disease, and operative type in the acute surgical site infection group were significantly different than those in the non-acute surgical site infection group (p < 0.05). Using binary logistic regression analyses, body mass index, smoking, diabetes mellitus, osteoporosis, preoperative antibiotics, fracture, operative type, operative time, blood loss, and drainage time were independent predictors of acute surgical site infection following lumbar surgery. In order to reduce the risk of infection following lumbar surgery, patients should be evaluated for the risk factors noted above.

  6. Which patients risk segmental kyphosis after short segment thoracolumbar fracture fixation with intermediate screws?

    PubMed

    Formica, Matteo; Cavagnaro, Luca; Basso, Marco; Zanirato, Andrea; Felli, Lamberto; Formica, Carlo; Di Martino, Alberto

    2016-10-01

    The use of intermediate screws in fractured vertebrae has been proposed to decrease the number of fused levels in thoracolumbar fractures and to enable short fixations. The aim of this study was to evaluate the results of this technique and to establish predictive factors involved in loss of segmental kyphosis correction (LKC). Forty-three patients who underwent short-segment spinal fixation with intermediate screws for a thoracolumbar spine fracture in a two-year time period were enrolled in the study. Patients had AO-type A3, A4 and B2 thoracolumbar fractures. Radiological parameters included segmental kyphosis (SK), vertebral wedge angle (VWA) and loss of anterior and posterior vertebral body height. Patients were evaluated up to one-year follow-up. The correlation between LKC and potential risk factors, such as smoking habit, sex, age, neurological status and BMI was evaluated. Mean preoperative SK was 16.5°±6.5°, and it decreased to 3.4°±3.5° postoperatively (P<0.01). At the one-year follow-up mean SK dropped to 5.5°±3.9° (P<0.01). Mean preoperative VWA was 20.0°±8.1°, and significantly improved to 6.3°±3.1° after surgery (P<0.01). There was a mean LKC of 1.8°±2.1°at one year. LKC mildly correlated with body mass index (BMI, r: +0.31), and obese patients (BMI>30) had an increased risk of LKC at the one-year follow-up (P=0.03; odds ratio [OR]=3.2). Analysis of the radiological data at one-year follow-up showed that all the evaluated parameters were associated with a mild loss of correction, with no impact on the clinical outcomes or implant failure. These findings confirm the trends reported in the literature. The correlation between LKC and clinical features, such as BMI, age, sex, smoking habit and preoperative neurological status was investigated. Interestingly, a positive correlation was observed between BMI and LKC, and obese patients with BMI>30 had an increased risk of LKC at one-year follow-up (OR 3.2); to our knowledge this finding has never before been reported. Short-segment fixation with intermediate screws is a viable technique with positive clinical and radiological outcomes at one-year follow-up. However, surgeons should be aware that in obese patients (BMI>30) this technique is associated with an increased risk of LKC. 3. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Gastroenterology-Urology Devices; Manual Gastroenterology-Urology Surgical Instruments and Accessories. Final rule; technical amendment.

    PubMed

    2017-03-01

    The Food and Drug Administration (FDA) is amending the identification of manual gastroenterology-urology surgical instruments and accessories to reflect that the device does not include specialized surgical instrumentation for use with urogyencologic surgical mesh specifically intended for use as an aid in the insertion, placement, fixation, or anchoring of surgical mesh during urogynecologic procedures ("specialized surgical instrumentation for use with urogynecologic surgical mesh"). These amendments are being made to reflect changes made in the recently issued final reclassification order for specialized surgical instrumentation for use with urogynecologic surgical mesh.

  8. Modified tension band wiring of medial malleolar ankle fractures.

    PubMed

    Georgiadis, G M; White, D B

    1995-02-01

    Twenty-two displaced medial malleolar ankle fractures that were treated surgically using the modified tension band method of Cleak and Dawson were retrospectively reviewed at an average follow-up of 25 months. The technique involves the use of a screw to anchor a figure-of-eight wire. There were no malreductions and all fractures healed. Problems with the technique included technical errors with hardware placement, medial ankle pain, and asymptomatic wire migration. Despite this, modified tension band wiring remains an acceptable method for fixation of selected displaced medial malleolar fractures. It is especially suited for small fracture fragments and osteoporotic bone.

  9. Copper-Doped Bioactive Glass as Filler for PMMA-Based Bone Cements: Morphological, Mechanical, Reactivity, and Preliminary Antibacterial Characterization.

    PubMed

    Miola, Marta; Cochis, Andrea; Kumar, Ajay; Arciola, Carla Renata; Rimondini, Lia; Verné, Enrica

    2018-06-06

    To promote osteointegration and simultaneously limit bacterial contamination without using antibiotics, we designed innovative composite cements containing copper (Cu)-doped bioactive glass powders. Cu-doped glass powders were produced by a melt and quenching process, followed by an ion-exchange process in a Cu salt aqueous solution. Cu-doped glass was incorporated into commercial polymethyl methacrylate (PMMA)-based cements with different viscosities. The realized composites were characterized in terms of morphology, composition, leaching ability, bioactivity, mechanical, and antibacterial properties. Glass powders appeared well distributed and exposed on the PMMA surface. Composite cements showed good bioactivity, evidencing hydroxyapatite precipitation on the sample surfaces after seven days of immersion in simulated body fluid. The leaching test demonstrated that composite cements released a significant amount of copper, with a noticeable antibacterial effect toward Staphylococcus epidermidis strain. Thus, the proposed materials represent an innovative and multifunctional tool for orthopedic prostheses fixation, temporary prostheses, and spinal surgery.

  10. Local Setup Reproducibility of the Spinal Column When Using Intensity-Modulated Radiation Therapy for Craniospinal Irradiation With Patient in Supine Position

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stoiber, Eva Maria, E-mail: eva.stoiber@med.uni-heidelberg.de; Department of Medical Physics, German Cancer Research Center, Heidelberg; Giske, Kristina

    Purpose: To evaluate local positioning errors of the lumbar spine during fractionated intensity-modulated radiotherapy of patients treated with craniospinal irradiation and to assess the impact of rotational error correction on these uncertainties for one patient setup correction strategy. Methods and Materials: 8 patients (6 adults, 2 children) treated with helical tomotherapy for craniospinal irradiation were retrospectively chosen for this analysis. Patients were immobilized with a deep-drawn Aquaplast head mask. Additionally to daily megavoltage control computed tomography scans of the skull, once-a-week positioning of the lumbar spine was assessed. Therefore, patient setup was corrected by a target point correction, derived frommore » a registration of the patient's skull. The residual positioning variations of the lumbar spine were evaluated applying a rigid-registration algorithm. The impact of different rotational error corrections was simulated. Results: After target point correction, residual local positioning errors of the lumbar spine varied considerably. Craniocaudal axis rotational error correction did not improve or deteriorate these translational errors, whereas simulation of a rotational error correction of the right-left and anterior-posterior axis increased these errors by a factor of 2 to 3. Conclusion: The patient fixation used allows for deformations between the patient's skull and spine. Therefore, for the setup correction strategy evaluated in this study, generous margins for the lumbar spinal target volume are needed to prevent a local geographic miss. With any applied correction strategy, it needs to be evaluated whether or not a rotational error correction is beneficial.« less

  11. Assessment of the effects of different sample perfusion procedures on phase-contrast tomographic images of mouse spinal cord

    NASA Astrophysics Data System (ADS)

    Stefanutti, E.; Sierra, A.; Miocchi, P.; Massimi, L.; Brun, F.; Maugeri, L.; Bukreeva, I.; Nurmi, A.; Begani Provinciali, G.; Tromba, G.; Gröhn, O.; Giove, F.; Cedola, A.; Fratini, M.

    2018-03-01

    Synchrotron X-ray Phase Contrast micro-Tomography (SXrPCμT) is a powerful tool in the investigation of biological tissues, including the central nervous system (CNS), and it allows to simultaneously detect the vascular and neuronal network avoiding contrast agents or destructive sample preparations. However, specific sample preparation procedures aimed to optimize the achievable contrast- and signal-to-noise ratio (CNR and SNR, respectively) are required. Here we report and discuss the effects of perfusion with two different fixative agents (ethanol and paraformaldehyde) and with a widely used contrast medium (MICROFIL®) on mouse spinal cord. As a main result, we found that ethanol enhances contrast at the grey/white matter interface and increases the contrast in correspondence of vascular features and fibres, thus providing an adequate spatial resolution to visualise the vascular network at the microscale. On the other hand, ethanol is known to induce tissue dehydration, likely reducing cell dimensions below the spatial resolution limit imposed by the experimental technique. Nonetheless, neurons remain well visible using either perfused paraformaldehyde or MICROFIL® compound, as these latter media do not affect tissues with dehydration effects. Paraformaldehyde appears as the best compromise: it is not a contrast agent, like MICROFIL®, but it is less invasive than ethanol and permits to visualise well both cells and blood vessels. However, a quantitative estimation of the relative grey matter volume of each sample has led us to conclude that no significant alterations in the grey matter extension compared to the white matter occur as a consequence of the perfusion procedures tested in this study.

  12. Sublaminar fixation for traumatic lumbar fracture subluxation with lateral listhesis in a 2-year-old patient.

    PubMed

    Yanni, Daniel S; Cruz, Aurora S; Halim, Alexander Y; Gill, Amandip S; Muhonen, Michael G; Heary, Robert F; Goldstein, Ira M

    2018-05-04

    Pediatric spinal trauma can present a surgeon with difficult management decisions given the rarity of these cases, pediatric anatomy, and a growing spine. The need to stabilize a traumatically unstable pediatric spine can be an operative challenge given the lack of instrumentation available. The authors present a surgical technique and an illustrative case that may offer a novel, less disruptive method of stabilization. A 2-year-old girl presented after an assault with an L1-2 fracture subluxation with lateral listhesis and fractured jumped facets exhibited on CT scans. CT also showed intact growth plates at the vertebral body, pedicles, and posterior elements. MRI showed severe ligamentous injury, conus medullaris compression, and an epidural hematoma. Neurologically, the patient moved both lower extremities asymmetrically. Given the severity of the deformity and neurological examination and disruption of the stabilizing structures, the authors made the decision to surgically decompress the L-1 and L-2 segments with bilateral laminotomies, evacuate the epidural hematoma, and reduce the deformity with sublaminar stabilization using braided polyester cables bilaterally, thus preserving the growth plates. They also performed a posterolateral onlay fusion at L-1 and L-2 using autograft and allograft placed due to the facet disruption. At the 42-month follow-up, imaging showed fusion of L-1 and L-2 with good alignment, and the hardware was subsequently explanted. The patient was neurologically symmetric in strength, ambulating, and had preserved alignment. Her bones and spinal canal continued to grow in relation to the other levels.

  13. Biomechanical evaluation of different instrumentation for spinal stabilisation.

    PubMed

    Graftiaux, A G; Wattier, B; Gentil, P; Mazel, C; Skalli, W; Diop, A; Kehr, P H; Lavaste, F

    1995-12-01

    The varying problems following arthrodesis of the lumbar spine with rods or plates (too much rigidity for the first and insufficient stability for the second) have led us to conceive another type of material, flexible but with enough stability, to favorise healing of bone graft, and decrease the induced pathology on adjacent levels. An experimental study of three types of material: rigid, semi-rigid and flexible was performed on eighteen fresh cadaver spinal segments without and then with discectomy and corporectomy to find out the various types of behaviour. The flexible device seems more supple than the other materials tested: more mobility, less stiffness. Rising hysteresis is explained by plastic deformation. The semi-rigid device presents strong osseous stresses on the L3 level and a large hysteresis corresponding most likely to a mobility between the screws and plates. The rigid device has less mobility, especially in torsion, ascribed to the transverse connection. The stability is high with a small hysteresis. This is of value for bone loss or instability with displacement of the vertebral body.The second study was a modeling of the flexible device validated by comparison to the experimental study. The strains in the wire were high, decreasing with increasing diameter, but is still lower than the elastic limit. The proximity of the elastic limit may allow plastic deformation of the wire. Howewer less strains were found on the screw fixation but increase with the increase diameter of the wire. The influence of the bone quality on the behavior of the device was demonstrated.

  14. Alternative radiation-free registration technique for image-guided pedicle screw placement in deformed cervico-thoracic segments.

    PubMed

    Kantelhardt, Sven R; Neulen, Axel; Keric, Naureen; Gutenberg, Angelika; Conrad, Jens; Giese, Alf

    2017-10-01

    Image-guided pedicle screw placement in the cervico-thoracic region is a commonly applied technique. In some patients with deformed cervico-thoracic segments, conventional or 3D fluoroscopy based registration of image-guidance might be difficult or impossible because of the anatomic/pathological conditions. Landmark based registration has been used as an alternative, mostly using separate registration of each vertebra. We here investigated a routine for landmark based registration of rigid spinal segments as single objects, using cranial image-guidance software. Landmark based registration of image-guidance was performed using cranial navigation software. After surgical exposure of the spinous processes, lamina and facet joints and fixation of a reference marker array, up to 26 predefined landmarks were acquired using a pointer. All pedicle screws were implanted using image guidance alone. Following image-guided screw placement all patients underwent postoperative CT scanning. Screw positions as well as intraoperative and clinical parameters were retrospectively analyzed. Thirteen patients received 73 pedicle screws at levels C6 to Th8. Registration of spinal segments, using the cranial image-guidance succeeded in all cases. Pedicle perforations were observed in 11.0%, severe perforations of >2 mm occurred in 5.4%. One patient developed a transient C8 syndrome and had to be revised for deviation of the C7 pedicle screw. No other pedicle screw-related complications were observed. In selected patients suffering from pathologies of the cervico-thoracic region, which impair intraoperative fluoroscopy or 3D C-arm imaging, landmark based registration of image-guidance using cranial software is a feasible, radiation-saving and a safe alternative.

  15. Scaffold translation: barriers between concept and clinic.

    PubMed

    Hollister, Scott J; Murphy, William L

    2011-12-01

    Translation of scaffold-based bone tissue engineering (BTE) therapies to clinical use remains, bluntly, a failure. This dearth of translated tissue engineering therapies (including scaffolds) remains despite 25 years of research, research funding totaling hundreds of millions of dollars, over 12,000 papers on BTE and over 2000 papers on BTE scaffolds alone in the past 10 years (PubMed search). Enabling scaffold translation requires first an understanding of the challenges, and second, addressing the complete range of these challenges. There are the obvious technical challenges of designing, manufacturing, and functionalizing scaffolds to fill the Form, Fixation, Function, and Formation needs of bone defect repair. However, these technical solutions should be targeted to specific clinical indications (e.g., mandibular defects, spine fusion, long bone defects, etc.). Further, technical solutions should also address business challenges, including the need to obtain regulatory approval, meet specific market needs, and obtain private investment to develop products, again for specific clinical indications. Finally, these business and technical challenges present a much different model than the typical research paradigm, presenting the field with philosophical challenges in terms of publishing and funding priorities that should be addressed as well. In this article, we review in detail the technical, business, and philosophical barriers of translating scaffolds from Concept to Clinic. We argue that envisioning and engineering scaffolds as modular systems with a sliding scale of complexity offers the best path to addressing these translational challenges. © Mary Ann Liebert, Inc.

  16. Fortifying the Bone-Implant Interface Part 1: An In Vitro Evaluation of 3D-Printed and TPS Porous Surfaces

    PubMed Central

    Lindsey, Derek P.; Bahney, Chelsea S.; Woods, Shane A.; Wolfe, Mark L.; Yerby, Scott A.

    2017-01-01

    Background An aging society and concomitant rise in the incidence of impaired bone health have led to the need for advanced osteoconductive spinal implant surfaces that promote greater biological fixation (e.g. for interbody fusion cages, sacroiliac joint fusion implants, and artificial disc replacements). Additive manufacturing, i.e. 3D-printing, may improve bone integration by generating biomimetic spinal implant surfaces that mimic bone morphology. Such surfaces may foster an enhanced cellular response compared to traditional implant surfacing processes. Methods This study investigated the response of human osteoblasts to additive manufactured (AM) trabecular-like titanium implant surfaces compared to traditionally machined base material with titanium plasma spray (TPS) coated surfaces, with and without a nanocrystalline hydroxyapatite (HA) coating. For TPS-coated discs, wrought Ti6Al4V ELI was machined and TPS-coating was applied. For AM discs, Ti6Al4V ELI powder was 3D-printed to form a solid base and trabecular-like porous surface. The HA-coating was applied via a precipitation dip-spin method. Surface porosity, pore size, thickness, and hydrophilicity were characterized. Initial cell attachment, proliferation, alkaline phosphatase (ALP) activity, and calcium production of hFOB cells (n=5 per group) were measured. Results Cells on AM discs exhibited expedited proliferative activity. While there were no differences in mean ALP expression and calcium production between TPS and AM discs, calcium production on the AM discs trended 48% higher than on TPS discs (p=0.07). Overall, HA-coating did not further enhance results compared to uncoated TPS and AM discs. Conclusions Results demonstrate that additive manufacturing allows for controlled trabecular-like surfaces that promote earlier cell proliferation and trends toward higher calcium production than TPS coating. Results further showed that nanocrystalline HA may not provide an advantage on porous titanium surfaces. Clinical Relevance Additive manufactured porous titanium surfaces may induce a more osteogenic environment compared to traditional TPS, and thus present as an attractive alternative to TPS-coating for orthopedic spinal implants. PMID:28765799

  17. Transcranial motor evoked potential waveform changes in corrective fusion for adolescent idiopathic scoliosis.

    PubMed

    Kobayashi, Kazuyoshi; Imagama, Shiro; Ito, Zenya; Ando, Kei; Hida, Tetsuro; Ito, Kenyu; Tsushima, Mikito; Ishikawa, Yoshimoto; Matsumoto, Akiyuki; Nishida, Yoshihiro; Ishiguro, Naoki

    2017-01-01

    OBJECTIVE Corrective surgery for spinal deformities can lead to neurological complications. Several reports have described spinal cord monitoring in surgery for spinal deformity, but only a few have included patients younger than 20 years with adolescent idiopathic scoliosis (AIS). The goal of this study was to evaluate the characteristics of cases with intraoperative transcranial motor evoked potential (Tc-MEP) waveform deterioration during posterior corrective fusion for AIS. METHODS A prospective database was reviewed, comprising 68 patients with AIS who were treated with posterior corrective fusion in a prospective database. A total of 864 muscles in the lower extremities were chosen for monitoring, and acceptable baseline responses were obtained from 819 muscles (95%). Intraoperative Tc-MEP waveform deterioration was defined as a decrease in intraoperative amplitude of ≥ 70% of the control waveform. Age, Cobb angle, flexibility, operative time, estimated blood loss (EBL), intraoperative body temperature, blood pressure, number of levels fused, and correction rate were examined in patients with and without waveform deterioration. RESULTS The patients (3 males and 65 females) had an average age of 14.4 years (range 11-19 years). The mean Cobb angles before and after surgery were 52.9° and 11.9°, respectively, giving a correction rate of 77.4%. Fourteen patients (20%) exhibited an intraoperative waveform change, and these occurred during incision (14%), after screw fixation (7%), during the rotation maneuver (64%), during placement of the second rod after the rotation maneuver (7%), and after intervertebral compression (7%). Most waveform changes recovered after decreased correction or rest. No patient had a motor deficit postoperatively. In multivariate analysis, EBL (OR 1.001, p = 0.085) and number of levels fused (OR 1.535, p = 0.045) were associated with waveform deterioration. CONCLUSIONS Waveform deterioration commonly occurred during rotation maneuvers and more frequently in patients with a larger preoperative Cobb angle. The significant relationships of EBL and number of levels fused with waveform deterioration suggest that these surgical invasions may be involved in waveform deterioration.

  18. AnAnkle Trial study protocol: a randomised trial comparing pain profiles after peripheral nerve block or spinal anaesthesia for ankle fracture surgery.

    PubMed

    Sort, Rune; Brorson, Stig; Gögenur, Ismail; Møller, Ann Merete

    2017-06-02

    Ankle fracture surgery is a common procedure, but the influence of anaesthesia choice on postoperative pain and quality of recovery is poorly understood. Some authors suggest a benefit of peripheral nerve block (PNB) in elective procedures, but the different pain profile following acute fracture surgery and the rebound pain on cessation of the PNB both remain unexplored. We present an ongoing randomised study aiming to compare primary PNB anaesthesia with spinal anaesthesia for ankle fracture surgery regarding postoperative pain profiles and quality of recovery. AnAnkle Trial is a randomised, dual-centre, open-label, blinded analysis trial of 150 adult patients undergoing primary internal fixation of an ankle fracture. Main exclusion criteria are habitual opioid use, impaired pain sensation, other painful injuries or cognitive impairment. The intervention is ultrasound-guided popliteal sciatic (20 mL) and saphenal nerve (8 mL) PNB with ropivacaine 7.5 mg/mL, and controls receive spinal anaesthesia (2 mL) with hyperbaric bupivacaine 5 mg/mL. Postoperatively all receive paracetamol, ibuprofen and patient-controlled intravenous morphine on demand. Morphine consumption and pain scores are registered in the first 27 hours and reported as an integrated pain score as the primary endpoint. Pain score intervals are 3 hours and we will use the area under curve to get a longitudinal measure of pain. Secondary outcomes include rebound pain on cessation of anaesthesia, opioid side effects (Opioid-Related Symptom Distress Scale), quality of recovery (Danish Quality of Recovery-15 score) and pain scores and medication days 1-7 (diary). The study has been approved by the Regional Ethics Committees in the Capital Region of Denmark, the Danish Data Protection Agency and the Danish Health and Medical Authority. We will publish the results in international peer-reviewed medical journals. AnAnkle Trial is registered in the European Clinical Trials Database (EudraCT 2015-001108-76). © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. Concomitant intramedullary arteriovenous malformation and a vertebral hemangioma of cervical spine discovered by a pathologic fracture during bicycle accident.

    PubMed

    Ayhan, Selim; Palaoglu, Selcuk; Geyik, Serdar; Saatci, Isil; Onal, Mehmet Bulent

    2015-01-01

    Spinal intramedullary arteriovenous malformations are uncommon and a challenging type of neurosurgical entities. They are rarely located to cervical segment. On the other hand, although hemangiomas are relatively common bone tumors, cervical involvement is again rare and clinically significant ones are infrequent. A 14 year-old-male patient referred to an academic tertiary care unit and presented with neck pain and left hand weakness. Neurological examination revealed motor strength deficit at intrinsic muscles and hyperesthesia at the left hand. Furthermore the pathological reflexes were positive on the left hand side. Imaging studies showed compression fracture, lytic changes resembling a hemangioma at C7 vertebra, and also an intramedullary vascular pathology at C5-6 level which was shown to be an intradural-intramedullary arteriovenous malformation (AVM) on digital subtraction angiography. Based on neurological and radiological findings, the decision was to treat the patient. After embolization of the AVM, the neurological condition of the patient deteriorated and immediate MRI scan of the cervical spine revealed edema of the spinal cord at the C5-6 level. Thus an emergent surgery was performed and C5-6-7 laminectomies with C5-T2 posterior fixation and arthrodesis were implemented. A second stage operation was carried out as C7 corpectomy with a distractable titanium cage 2 weeks after initial surgery. A follow-up evaluation at five years revealed 4/5 motor strength on his left intrinsic hand muscles and mild hyperactive deep tendon reflexes. Imaging studies at the postoperative period showed stable placement of the construct and no evidence of contrast enhancement at the C5-6 level inside the spinal cord. A rare case of multiple pathologies affecting the cervical spine, coincidentally diagnosed after a pathological fracture during a bicycle accident as vertebral hemangioma and intradural-intramedullary AVM that was successfully treated with early detection, have been presented. One should assess such patients under multidisciplinary fashion and treat on a case-by-case basis for achieving the best results in patient care.

  20. The Use of 3D Printing Technology in the Ilizarov Method Treatment: Pilot Study.

    PubMed

    Burzyńska, Karolina; Morasiewicz, Piotr; Filipiak, Jarosław

    2016-01-01

    Significant developments in additive manufacturing technology have occurred in recent years. 3D printing techniques can also be helpful in the Ilizarov method treatment. The aim of this study was to evaluate the usefulness of 3D printing technology in the Ilizarov method treatment. Physical models of bones used to plan the spatial design of Ilizarov external fixator were manufactured by FDM (Fused Deposition Modeling) spatial printing technology. Bone models were made of poly(L-lactide) (PLA). Printed 3D models of both lower leg bones allow doctors to prepare in advance for the Ilizarov method treatment: detailed consideration of the spatial configuration of the external fixation, experimental assembly of the Ilizarov external fixator onto the physical models of bones prior to surgery, planning individual osteotomy level and Kirschner wires introduction sites. Printed 3D bone models allow for accurate preparation of the Ilizarov apparatus spatially matched to the size of the bones and prospective bone distortion. Employment of the printed 3D models of bone will enable a more precise design of the apparatus, which is especially useful in multiplanar distortion and in the treatment of axis distortion and limb length discrepancy in young children. In the course of planning the use of physical models manufactured with additive technology, attention should be paid to certain technical aspects of model printing that have an impact on the accuracy of mapping of the geometry and physical properties of the model. 3D printing technique is very useful in 3D planning of the Ilizarov method treatment.

  1. Visual search strategies of experienced and nonexperienced swimming coaches.

    PubMed

    Moreno, Francisco J; Saavedra, José M; Sabido, Rafael; Luis, Vicente; Reina, Raúl

    2006-12-01

    The aim of this study consists of the application of an experimental protocol that allows information to be obtained about the visual search strategies elaborated by swimming coaches. 16 swimming coaches participated. The Experienced group (n=8) had 16.1 yr. (SD=8.2) of coaching experience and at least five years of experience in underwater vision. The Nonexperienced group in underwater vision (n= 8) had 4.2 yr. (SD= 4.0) of coaching experience. Participants were tested in a laboratory environment using a video-projected sample of the crawl stroke of an elite swimmer. This work discusses the main areas of the swimmer's body used by coaches to identify and analyse errors in technique from overhead and underwater perspectives. In front-underwater videos, body roll and mid-water were the locations of the display with higher percentages of fixation time. In the side-underwater slow videos, the upper body was the location with higher percentages of visual fixation time and was used to detect the low elbow fault. Side-overhead takes were not the best perspectives to pick up information directly about performance of the arms; coaches attended to the head as a reference for their visual search. The observation and technical analysis of the hands and arms were facilitated by an underwater perspective. Visual fixation on the elbow served as a reference to identify errors in the upper body. The side-underwater perspective may be an adequate way to identify correct knee angles in leg kicking and the alignment of a swimmer's body and leg actions.

  2. Wrist Arthrodesis for Failed Total Wrist Arthroplasty.

    PubMed

    Adams, Brian D; Kleinhenz, Ben P; Guan, Justin J

    2016-06-01

    Treatment options for failed total wrist arthroplasty include implant revision, resection arthroplasty, and arthrodesis. Variable results associated with different techniques have been reported for arthrodesis and the procedure has substantial technical challenges, including restoration of wrist height, obtaining stable fixation, and achieving bony fusion. This study evaluates the radiographic results of a surgical technique for conversion of a failed arthroplasty to an arthrodesis. A retrospective chart and radiograph review was performed in 20 wrists in 18 patients in whom conversion to an arthrodesis was performed using a contoured cancellous femoral head structural allograft and a wrist arthrodesis plate. Supplemental demineralized bone matrix combined with corticocancellous allograft chips was also used in 15 wrists. Median age at arthrodesis was 61 years (range, 45-78 years), and median follow-up was 34 months (range, 4-71 months). Nineteen of 20 wrists fused following the index procedure at a median of 4 months (range, 3-7 months). Proximal plate loosening occurred in 1 wrist but the joint still fused at 6 months; a successful osteotomy and revision of screw fixation was done 2 years later to correct the deformity and hardware irritation in this case. Complications were otherwise limited to 1 superficial infection that resolved with intravenous antibiotics. This technique for conversion of a failed total wrist arthroplasty to a wrist arthrodesis is safe, effective, and versatile. Wrist deformity is corrected, wrist height can be restored, stable fixation is obtained, and a high rate of fusion is achieved despite filling large defects using structural cancellous allograft. Therapeutic IV. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  3. The failure mode of two reabsorbable fixation systems: Swivelock with Fibertape versus Bio-Corkscrew with Fiberwire in bovine rotator cuff.

    PubMed

    De Carli, Angelo; Lanzetti, Riccardo Maria; Monaco, Edoardo; Labianca, Luca; Mossa, Luigi; Ferretti, Andrea; Feretti, Andrea

    2012-11-01

    Despite technical advances in rotator cuff surgery, recurrent or persistent defects in the repaired tendon continue to occur. The improved strength of sutures and suture anchors has shown that the most common site of failure is the suture-tendon interface. The purpose of this study was to compare two different types of repair under both cyclic and load-to-failure conditions. The hypothesis is that the use of a fixation system with knotless anchor and taped suture results in better biomechanical performance, under both cyclic and load-to-failure conditions. Thirty bovine shoulder specimens were randomly assigned to two group tests: the Swivelock 5-mm anchor with Fibertape (Group A) and the Bio-Corkscrew 5 mm with Fiberwire (Group B). We simulated the reconstruction of a rotator cuff tear with a single-row technique, performing a tenodesis with types A and B fixation. Each specimen underwent cyclic testing from 5 to 30 N for 30 cycles, followed by load-to-failure testing, in order to calculate the ultimate failure load (UFL). Load-to-failure tests revealed a significantly higher UFL in Group A than in Group B. Wire fixing failed at the anchor loop whereas tape fixing failed at the sutures, suture-tendon interface, and anchors. Cyclic testing revealed no significantly greater slippage between the two groups. Stiffness values were not statistically significantly different. In all cases, tendons remained intact until the end of the cyclic testing. The tape structure is biomechanically stronger than the wire structure.

  4. Midterm outcomes of the Zenith Renu AAA Ancillary Graft.

    PubMed

    Jim, Jeffrey; Rubin, Brian G; Geraghty, Patrick J; Money, Samuel R; Sanchez, Luis A

    2011-08-01

    The Zenith Renu abdominal aortic aneurysm (AAA) Ancillary Graft (Cook Medical Inc, Bloomington, Ind) provides active proximal fixation for treatment of pre-existing endografts with failed or failing proximal fixation or seal. The purpose of this study was to evaluate the midterm outcomes of treatment with this device. From September 2005 to November 2006, a prospective, nonrandomized, multicenter, postmarket registry was utilized to collect physician experiences from 151 cases (89 converters and 62 main body extensions) at 95 institutions. Preoperative indications and procedural and postimplantation outcomes were collected and analyzed. Technical success and clinical success were determined as defined by the Society of Vascular Surgery reporting standards. Patients were predominantly male (87%) with a mean age of 77 years. The interval between the original endograft implantation to Renu treatment was 43.4 ± 18.7 months. The indications for treatment were endoleak (n = 111), migration (n = 136), or both (n = 94). Technical success was 98.0% with two cases of intraoperative conversion and one case of persistent type IA endoleak. The median follow-up for the cohort was 45.0 months (range, 0-56 months; interquartile range, 25.0 months). Overall, 32 cases had treatment failures that included at least one of the following: death (n = 5), type I/III endoleak (n = 18), graft infection (n = 1), thrombosis (n = 1), aneurysm enlargement >5 mm (n = 9), rupture (n = 4), conversion (n = 9, with 7 after 30 days), and migration (n = 1). Overall, the clinical success for the entire cohort during the follow-up period was 78.8% (119/151). The postmarket registry data confirm that the Zenith Renu AAA Ancillary Graft can be used to treat endovascular repairs that failed due to proximal attachment failures. The salvage treatment with the Renu device had high technical success rate and resulted in clinical success in a majority of patients (78.8%). While failed endovascular repairs can be salvaged, a clinical failure in one of five patients still emphasizes the importance of patient and device selection during initial endovascular aneurysm repair to ensure durable success. Copyright © 2011 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  5. Electromechanical gait training with functional electrical stimulation: case studies in spinal cord injury.

    PubMed

    Hesse, S; Werner, C; Bardeleben, A

    2004-06-01

    Single case studies. To describe the technique of intensive locomotor training on an electromechanical gait trainer (GT) combined with functional electrical stimulation (FES). Neurological Rehabilitation Clinic, Berlin, Germany. Four spinal cord-injured (SCI) patients, one tetraparetic, two paraparetic, and one patient with an incomplete cauda syndrome, more than 3 months postinjury, who were unable to walk at all, or with two therapists. They received 25 min of locomotor training on the GT plus FES daily for 5 weeks in addition to the regular therapy. The patients tolerated the programme well, and therapists rated the programme less strenuous compared to manually assisted treadmill training. Gait ability improved in all four patients; three patients could walk independently on the floor with the help of technical aids, and one required the help of one therapist after therapy; gait speed and endurance more than doubled, and the gastrocnemius activity increased in the patients with a central paresis. This combined technique allows intensive locomotor therapy in SCI subjects with reduced effort from the therapists. The patients' improved walking ability confirmed the potential of locomotor therapy in SCI subjects.

  6. Proximal spinal muscular atrophy: current orthopedic perspective

    PubMed Central

    Haaker, Gerrit; Fujak, Albert

    2013-01-01

    Spinal muscular atrophy (SMA) is a hereditary neuromuscular disease of lower motor neurons that is caused by a defective “survival motor neuron” (SMN) protein that is mainly associated with proximal progressive muscle weakness and atrophy. Although SMA involves a wide range of disease severity and a high mortality and morbidity rate, recent advances in multidisciplinary supportive care have enhanced quality of life and life expectancy. Active research for possible treatment options has become possible since the disease-causing gene defect was identified in 1995. Nevertheless, a causal therapy is not available at present, and therapeutic management of SMA remains challenging; the prolonged survival is increasing, especially orthopedic, respiratory and nutritive problems. This review focuses on orthopedic management of the disease, with discussion of key aspects that include scoliosis, muscular contractures, hip joint disorders, fractures, technical devices, and a comparative approach of conservative and surgical treatment. Also emphasized are associated complications including respiratory involvement, perioperative care and anesthesia, nutrition problems, and rehabilitation. The SMA disease course can be greatly improved with adequate therapy with established orthopedic procedures in a multidisciplinary therapeutic approach. PMID:24399883

  7. Aneurysm of the intradural artery of Adamkiewicz treated with muslin wrapping: technical case report.

    PubMed

    Vishteh, A G; Brown, A P; Spetzler, R F

    1997-01-01

    An exceedingly rare, isolated spinal arterial aneurysm and its management are presented. A 30-year-old man who presented with severe lower back pain and headache underwent a computed tomographic study of his head that disclosed nothing abnormal and a lumbar puncture that revealed bloody, xanthochromic cerebrospinal fluid. The findings from cerebral angiography were normal, and the results from spinal angiography were consistent with a diagnosis of an aneurysm of the artery of Adamkiewicz. A transthoracic approach with a partial T11 vertebrectomy gained exposure to this anteriorly located lesion. A fusiform aneurysm of the intradural portion of the artery of Adamkiewicz was discovered. Excision of the aneurysm with a vascular bypass was deemed impossible. The lesion was treated with muslin wrapping. One year after surgery, the patient remains at his baseline neurological condition. A review of the literature revealed only one other reported case of a ruptured aneurysm of the artery of Adamkiewicz, which was discovered postmortem. Therefore, this case represents the first report of a diagnosed and treated artery of Adamkiewicz aneurysm.

  8. Biomechanical stability of a supra-acetabular pedicle screw internal fixation device (INFIX) vs external fixation and plates for vertically unstable pelvic fractures.

    PubMed

    Vigdorchik, Jonathan M; Esquivel, Amanda O; Jin, Xin; Yang, King H; Onwudiwe, Ndidi A; Vaidya, Rahul

    2012-09-27

    We have recently developed a subcutaneous anterior pelvic fixation technique (INFIX). This internal fixator permits patients to sit, roll over in bed and lie on their sides without the cumbersome external appliances or their complications. The purpose of this study was to evaluate the biomechanical stability of this novel supraacetabular pedicle screw internal fixation construct (INFIX) and compare it to standard internal fixation and external fixation techniques in a single stance pelvic fracture model. Nine synthetic pelves with a simulated anterior posterior compression type III injury were placed into three groups (External Fixator, INFIX and Internal Fixation). Displacement, total axial stiffness, and the stiffness at the pubic symphysis and SI joint were calculated. Displacement and stiffness were compared by ANOVA with a Bonferroni adjustment for multiple comparisons The mean displacement at the pubic symphysis was 20, 9 and 0.8 mm for external fixation, INFIX and internal fixation, respectively. Plate fixation was significantly stiffer than the INFIX and external Fixator (P = 0.01) at the symphysis pubis. The INFIX device was significantly stiffer than external fixation (P = 0.017) at the symphysis pubis. There was no significant difference in SI joint displacement between any of the groups. Anterior plate fixation is stiffer than both the INFIX and external fixation in single stance pelvic fracture model. The INFIX was stiffer than external fixation for both overall axial stiffness, and stiffness at the pubic symphysis. Combined with the presumed benefit of minimizing the complications associated with external fixation, the INFIX may be a more preferable option for temporary anterior pelvic fixation in situations where external fixation may have otherwise been used.

  9. Biomechanical Evaluation of All-Polyethylene Pegged Bony Ingrowth Glenoid Fixation Techniques on Implant Micromotion.

    PubMed

    Wiater, Brett P; Moravek, James E; Kurdziel, Michael D; Baker, Kevin C; Wiater, J Michael

    2016-01-01

    Newer glenoid components that allow for hybrid cement fixation via traditional cementation of peripheral pegs and bony ingrowth into an interference-fit central peg introduce the possibility of long-term biological fixation. However, little biomechanical work has been done on the initial stability of these components and the various fixation options. We conducted a study in which all-polyethylene glenoid components with a centrally fluted peg were implanted in polyurethane blocks with interference-fit, hybrid cement, and fully cemented fixation (5 per fixation group). Biomechanical evaluation of glenoid loosening, according to ASTM Standard F-2028-12, subjected the glenoids to 50,000 cycles of rim loading, and glenoid component motion was recorded with 2 differential variable reluctance transducers fixed to each glenoid prosthesis. Fully cemented fixation exhibited significantly less mean distraction in comparison with interference-fit fixation (P < .001) and hybrid cement fixation (P < .001). Hybrid cement fixation exhibited significantly less distraction (P < .001), more compression (P < .001), and no significant difference in glenoid translation (P = .793) in comparison with interference-fit fixation. Fully cemented fixation exhibited the most resistance to glenoid motion in comparison with hybrid cement fixation and interference-fit fixation. However, hybrid cement fixation and interference-fit fixation exhibited equivocal motion. Given these results, cementation of peripheral pegs may confer no additional initial stability over that provided by uncemented interference-fit fixation.

  10. Endoscopic neurosurgery "around the corner" with a rigid endoscope. Technical note.

    PubMed

    Hopf, N J

    1999-03-01

    Endoscopically "working around the corner" is presently restricted to the use of flexible endoscopes or an endoscope-assisted microneurosurgical (EAM) technique. In order to overcome the limitations of these solutions, endoscopic equipment and techniques were developed for "working around the corner" with rigid endoscopes. A steering insert with a 5 French working channel is capable of steering instruments around the corner by actively bending the guiding track and consecutively the instrument. A special fixation device enables strict axial rotation of the endoscope in the operating field. Endoscopic procedures "around the corner", including aqueductal stenting, pellucidotomy, third ventriculostomy and biopsy were performed in human cadavers. Special features of the used pediatric neuroendoscope system, i.e., reliable fixation, axial rotation, and controlled steering of instruments, increase the safety and reduce the surgical traumatization in selected cases, such as obstructive hydrocephalus due to a mass lesion in the posterior third ventricle, since endoscopic third ventriculostomy and biopsy can be performed through the same burr hole trephination. Limitations of this technique are given by the size of the foramen of Monro and the height of the third ventricle as well as by the bending angle of the instruments (40-50 degrees).

  11. Posterior root tear fixation of the lateral meniscus combined with arthroscopic ACL double-bundle reconstruction: technical note of a transosseous fixation using the tibial PL tunnel.

    PubMed

    Forkel, Philipp; Petersen, Wolf

    2012-03-01

    According to our observation in ACL reconstruction, we find root tears of the posterior horn of the lateral meniscus as a common concomitant injury in ACL-deficient knees. This might be a consequence of initial trauma or of the increased anterior-posterior translation of the tibia and an overload impact on the posterior meniscus root in ACL-deficient knees. A tear of the posterior horn of the medial meniscus causes a 25% increase in peak pressure in the medial compartment compared with that found in the intact condition. The repair restores the peak contact pressure to normal (Allaire et al. in J Bone Joint Surg Am 90(9):1922-1931, [2008]). A tear of the posterior horn of the lateral meniscus might have similar consequences. We hypothesize the surgical anatomical reattachment of the root at the tibia helping to restore knee joint kinematics and helping to advance ACL-graft function. This article presents an arthroscopical technique to reattach the posterior meniscus root in combination with ACL double-bundle reconstruction. The procedure uses the tibial PL tunnel to fix the meniscus suture.

  12. Update on mandibular condylar fracture management.

    PubMed

    Weiss, Joshua P; Sawhney, Raja

    2016-08-01

    Fractures of the mandibular condyle have provided a lasting source of controversy in the field of facial trauma. Concerns regarding facial nerve injury as well as reasonable functional outcomes with closed management led to a reluctance to treat with an open operative intervention. This article reviews how incorporating new technologies and surgical methods have changed the treatment paradigm. Multiple large studies and meta-analyses continue to demonstrate superior outcomes for condylar fractures when managed surgically. Innovations, including endoscopic techniques, three-dimensional miniplates, and angled drills provide increased options in the treatment of condylar fractures. The literature on pediatric condylar fractures is limited and continues to favor a more conservative approach. There continues to be mounting evidence in radiographic, quality of life, and functional outcome studies to support open reduction with internal fixation for the treatment of condylar fractures in patients with malocclusion, significant displacement, or dislocation of the temporomandibular joint. The utilization of three-dimensional trapezoidal miniplates has shown improved outcomes and theoretically enhanced biomechanical properties when compared with traditional fixation with single or double miniplates. Endoscopic-assisted techniques can decrease surgical morbidity, but are technically challenging, require skilled assistants, and utilize specialized equipment.

  13. Multiple Rib Nonunion: Open Reduction and Internal Fixation and Iliac Crest Bone Graft Aspirate.

    PubMed

    Kaplan, Daniel J; Begly, John; Tejwani, Nirmal

    2017-08-01

    Rib fractures are a common chest injury that can typically be treated nonoperatively. However, a percentage of these will go on to nonunion, either because of unique characteristics of the fracture itself or because of a variety of poor healing factors of the host. If a patient has continued symptomology beyond 3 months, surgeons may consider operative management. Although isolated resection of fibrous scar tissue from the nonunion site may be sufficient in some cases, it may also be necessary to provide additional structural integrity to the rib depending on the extent of the fracture pattern and resection. This goal can be achieved operatively with rib plating and bone grafting to promote healing. This video demonstrates the use of plating in the treatment of rib nonunion. It begins with relevant background information on rib fractures and nonunions, then details the approach, open reduction and internal fixation of 3 ribs using plates and bone graft aspirate. Pearls and pitfalls are included during the surgical technique aspect of the video to both help guide surgeons new to the procedure and provide potentially advantageous technical details to more experienced surgeons.

  14. Comparison of clinical results for the use of ethyl acetate and diethyl ether in the formalin-ether sedimentation technique performed on polyvinyl alcohol-preserved specimens.

    PubMed Central

    Garcia, L S; Shimizu, R

    1981-01-01

    One hundred fecal specimens preserved in polyvinyl alcohol fixative were examined by the Formalin-ether sedimentation technique with ethyl acetate substituted for diethyl ether. Technical performance of the procedures, appearance and amount of sediment obtained, and organism morphology were comparable. Also, ethyl acetate is less flammable and, therefore, less dangerous to use than diethyl ether. Results of parasite recovery when diethyl ether or ethyl acetate was used revealed few clinical relevant differences, most of which could also have been attributed to other variables inherent in this type of diagnostic testing. PMID:7229014

  15. Dredging Operations Technical Support Program. Transformation, Fixation, and Mobilization of Arsenic and Antimony in Contaminated Sediments.

    DTIC Science & Technology

    1984-01-01

    transferred -. to a 2.8-f wide mouth erlenmeyer flask. Sufficient distiLled deionized 1 38 -... 3 .° - . N,. 0 a V0 1- f I. S.0 cc SL ’S. 0 *1’*, -E C) C 5...water-to- dry -sediment weight ratio of 15:1. The sediment-water mixtures were kept in suspension by continuous stirring with a magnetic stirrer. Sediment...pH 5.0, pit 6.5, and pH 8.0). Each Eh-pH combination was amended with 75 Wg of As(V)/g dry weight of sediment as sodium arsenate and 25 wg Sb/g dry

  16. Chemical Fixation of CO2 in Coal Combustion Products and Recycling through Biosystems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    C. Henry Copeland; Paul Pier; Samantha Whitehead

    2001-09-30

    This Annual Technical Progress Report presents the principle results in enhanced growth of algae using coal combustion products as a catalyst to increase bicarbonate levels in solution. A co-current reactor is present that increases the gas phase to bicarbonate transfer rate by a factor of five to nine. The bicarbonate concentration at a given pH is approximately double that obtained using a control column of similar construction. Algae growth experiments were performed under laboratory conditions to obtain baseline production rates and to perfect experimental methods. The final product of this initial phase in algae production is presented.

  17. The “weekend warrior”: Fact or fiction for major trauma?

    PubMed Central

    Roberts, Derek J.; Ouellet, Jean-Francois; McBeth, Paul B.; Kirkpatrick, Andrew W.; Dixon, Elijah; Ball, Chad G.

    2014-01-01

    Background The “weekend warrior” engages in demanding recreational sporting activities on weekends despite minimal physical activity during the week. We sought to identify the incidence and injury patterns of major trauma from recreational sporting activities on weekends versus weekdays. Methods We performed a retrospective cohort study using the Alberta Trauma Registry comparing all adults who were severely injured (injury severity score [ISS] ≥ 12) while engaging in physical activity on weekends versus weekdays between 1995 and 2009. Results Among the 351 identified patients (median ISS 18; median hospital stay 6 d; mortality 6.6%), significantly more were injured on the weekend than during the week (54.8% v. 45.2%, p = 0.016). Common mechanisms were motocross (23.6%), hiking or mountain/rock climbing (15.4%), skateboarding or rollerblading (12.3%), hockey/ice-skating (10.3%) and aircraft- (9.9%) and water-related (7.7%) activities. This distribution was similar regardless of the day of the week. Most patients were injured as a result of a ground-level (21.9%) or higher fall while hiking, mountain climbing or rock climbing (25.9%); motocross-related incidents (24.2%); or collision with a tree, person, man-made object or moving vehicle (14.0%). Injury patterns were similar across both groups (all p > 0.05): head (55.8%), spine (35.1%), chest (35.0%), extremities (31.1%), face (17.4%), abdomen (13.1%). Surgical intervention was required in 41% of patients: 15.1% required open reduction and internal fixation, 8.3% spinal fixation, 7.4% craniotomy, 5.1% facial repair and 4.3% laparotomy. Conclusion The weekend warrior concept may be a validated entity for major trauma. PMID:24869618

  18. [Use of the Omega plate for stabilisation of acetabular fractures: first experience].

    PubMed

    Šrám, J; Taller, S; Lukáš, R; Endrych, L

    2013-01-01

    The aim of our study is to solve the problem of insufficient fixation of comminuted fractures of the quadrilateral plane and the iliopectineal line. These fixation problems occur while using the standard narrow 3.5 mm fixation plate applied from a modified Stoppa approach. A new plate developed by the authors--the Omega plate--fulfils the requirements. In the period 2010-2012, we performed 156 stabilisations of pelvic ring fractures and acetabular fractures. We used the modified Stoppa approach applying the standard fixation plate in 24 patients and the Omega plate in 15 patients. The patient group with the Omega plate included 10 male and five female patients with the average age of 61 years (range, 30-72). Only 11 patients were followed up, with an average period of 13.3 months, because one patient was lost to followup and three patients were shortly after surgery. The surgical technique of Omega plate application is described in detail. The clinical evaluation of post-operative results was based on the Harris Hip Score; the graphical results were rated using the Matta and Pohlemann criteria. The Stoppa approach alone was used in four patients, combination of two approaches (Stoppa and Kocher-Langenbeck approach) was used in six cases and three approaches were employed in five patients. No adverse intra- or post-operative events were recorded. Excellent or satisfactory graphical results were obtained in 12 patients and an unsatisfactory graphical outcome was recorded in three cases. In the follow-up period ranging from 8 to 22 months, 11 patients healed. Late complications included avascular femoral head necrosis in two and severe post-traumatic coxarthrosis in three patients. Due to these complications, all five patients underwent total hip arthroplasty without previous Omega plate removal at an average interval of 15 months from the primary pelvic surgery. They were not included in the follow-up evaluation. The remaining six patients had an average Harris Hip Score of 88 points (range, 81-98). The novel plate, shaped as a reverse omega letter, enables fixation of the quadrilateral area of the acetabulum through pressure of the arc of the plate against this area. Hitches, with holes for screw insertion, attached to the Omega plate in its middle part allow for fixation of fragments above the linea arcuata simply by pressure. Hitches in the ventral part provide for plate fixation to the ventral acetabular column and the superior pubic ramus. Hitches in the posterior segment of the plate facilitate insertion of a long screw in the posterior acetabular column from an additional iliac approach for stabilisation of simple acetabular fractures. The Omega plates are manufactured in several modifications. The Omega plate enables us to fix fractures of the superior pubic ramus, fractures of the anterior acetabular column, fractures of the quadrilateral acetabular plate, fractures in the iliopectineal line and simple fractures of the posterior column. A CT-defined projection of the pelvic inlet based on pre-operative CT scans allows us to choose the appropriate plate size and to shape the plate pre-operatively. After a technically well performed Stoppa approach and good fragment reduction, the application of an Omega plate is easy if our recommendations are followed. Fixation of all fragments of the anterior column and the quadrilateral plate is very stable and the Omega plate is highly resistant to secondary loss of reduction. A potential total hip arthroplasty does not require Omega plate removal.

  19. Biomechanical characteristics of fixation methods for floating pubic symphysis.

    PubMed

    Song, Wenhao; Zhou, Dongsheng; He, Yu

    2017-03-07

    Floating pubic symphysis (FPS) is a relatively rare injury caused by high-energy mechanisms. There are several fixation methods used to treat FPS, including external fixation, subcutaneous fixation, internal fixation, and percutaneous cannulated screw fixation. To choose the appropriate fixation, it is necessary to study the biomechanical performance of these different methods. The goal of this study was to compare the biomechanical characteristics of six methods by finite element analysis. A three-dimensional finite element model of FPS was simulated. Six methods were used in the FPS model, including external fixation (Ext), subcutaneous rod fixation (Sub-rod), subcutaneous plate fixation (Sub-plate), superior pectineal plate fixation (Int-sup), infrapectineal plate fixation (Int-ifa), and cannulated screw fixation (Int-scr). Compressive and rotational loads were then applied in all models. Biomechanical characteristics that were recorded and analyzed included construct stiffness, micromotion of the fracture gaps, von Mises stress, and stress distribution. The construct stiffness of the anterior pelvic ring was decreased dramatically when FPS occurred. Compressive stiffness was restored by the three internal fixation and Sub-rod methods. Unfortunately, rotational stiffness was not restored satisfactorily by the six methods. For micromotion of the fracture gaps, the displacement was reduced significantly by the Int-sup and Int-ifa methods under compression. The internal fixation methods and Sub-plate method performed well under rotation. The maximum von Mises stress of the implants was not large. For the plate-screw system, the maximum von Mises stress occurred over the region of the fracture and plate-screw joints. The maximum von Mises stress appeared on the rod-screw and screw-bone interfaces for the rod-screw system. The present study showed the biomechanical advantages of internal fixation methods for FPS from a finite element view. Superior stabilization of the anterior pelvic ring and fracture gaps was obtained by internal fixation. Subcutaneous fixation had satisfactory outcomes as well. Sub-rod fixation offered good anti-compression, while the Sub-plate fixation provided favorable anti-rotational capacity.

  20. The effect of hubs and shortcuts on fixation time in evolutionary graphs

    NASA Astrophysics Data System (ADS)

    Askari, Marziyeh; Moradi Miraghaei, Zeinab; Aghababaei Samani, Keivan

    2017-07-01

    How can a new species (like a gene, an idea, or a strategy) take over the whole of a population? This process, which is called fixation, is considerably affected by the structure of the population. There are two key quantities to quantify the fixation process, namely fixation probability and fixation time. Fixation probability has been vastly studied in recent years, but fixation time has not been completely explored, yet. This is because the discovery of a relationship between fixation time and network structure is quite challenging. In this paper we investigate this relationship for a number of well-known complex networks. We show that the existence of a few high-degree nodes (hubs) in the network results in a longer fixation time, while the existence of a few short-cuts decreases the fixation time. Furthermore we investigate the effect of network parameters, such as connection probability, on fixation time. We show that by increasing the density of edges, fixation time decreases for all types of studied networks. Finally, we survey the effect of rewiring probability in a Watts-Strogatz network on fixation time.

  1. SU-C-17A-07: The Development of An MR Accelerator-Enabled Planning-To-Delivery Technique for Stereotactic Palliative Radiotherapy Treatment of Spinal Metastases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoogcarspel, S J; Kontaxis, C; Velden, J M van der

    2014-06-01

    Purpose: To develop an MR accelerator-enabled online planning-todelivery technique for stereotactic palliative radiotherapy treatment of spinal metastases. The technical challenges include; automated stereotactic treatment planning, online MR-based dose calculation and MR guidance during treatment. Methods: Using the CT data of 20 patients previously treated at our institution, a class solution for automated treatment planning for spinal bone metastases was created. For accurate dose simulation right before treatment, we fused geometrically correct online MR data with pretreatment CT data of the target volume (TV). For target tracking during treatment, a dynamic T2-weighted TSE MR sequence was developed. An in house developedmore » GPU based IMRT optimization and dose calculation algorithm was used for fast treatment planning and simulation. An automatically generated treatment plan developed with this treatment planning system was irradiated on a clinical 6 MV linear accelerator and evaluated using a Delta4 dosimeter. Results: The automated treatment planning method yielded clinically viable plans for all patients. The MR-CT fusion based dose calculation accuracy was within 2% as compared to calculations performed with original CT data. The dynamic T2-weighted TSE MR Sequence was able to provide an update of the anatomical location of the TV every 10 seconds. Dose calculation and optimization of the automatically generated treatment plans using only one GPU took on average 8 minutes. The Delta4 measurement of the irradiated plan agreed with the dose calculation with a 3%/3mm gamma pass rate of 86.4%. Conclusions: The development of an MR accelerator-enabled planning-todelivery technique for stereotactic palliative radiotherapy treatment of spinal metastases was presented. Future work will involve developing an intrafraction motion adaptation strategy, MR-only dose calculation, radiotherapy quality-assurance in a magnetic field, and streamlining the entire treatment process on an MR accelerator.« less

  2. Public Regulatory Databases as a Source of Insight for Neuromodulation Devices Stimulation Parameters

    PubMed Central

    Kumsa, Doe; Steinke, G. Karl; Molnar, Gregory F.; Hudak, Eric M.; Montague, Fred W.; Kelley, Shawn C.; Untereker, Darrel F.; Shi, Alan; Hahn, Benjamin P.; Condit, Chris; Lee, Hyowon; Bardot, Dawn; Centeno, Jose A.; Krauthamer, Victor; Takmakov, Pavel A.

    2017-01-01

    Objective The Shannon model is often used to define an expected boundary between non-damaging and damaging modes of electrical neurostimulation. Numerous preclinical studies have been performed by manufacturers of neuromodulation devices using different animal models and a broad range of stimulation parameters while developing devices for clinical use. These studies are mostly absent from peer-reviewed literature, which may lead to this information being overlooked by the scientific community. We aimed to locate summaries of these studies accessible via public regulatory databases and to add them to a body of knowledge available to a broad scientific community. Methods We employed web search terms describing device type, intended use, neural target, therapeutic application, company name, and submission number to identify summaries for premarket approval (PMA) devices and 510(k) devices. We filtered these records to a subset of entries that have sufficient technical information relevant to safety of neurostimulation. Results We identified 13 product codes for 8 types of neuromodulation devices. These led us to devices that have 22 PMAs and 154 510(k)s and six transcripts of public panel meetings. We found one PMA for a brain, peripheral nerve, and spinal cord stimulator and five 510(k) spinal cord stimulators with enough information to plot in Shannon coordinates of charge and charge density per phase. Conclusions Analysis of relevant entries from public regulatory databases reveals use of pig, sheep, monkey, dog, and goat animal models with deep brain, peripheral nerve, muscle and spinal cord electrode placement with a variety of stimulation durations (hours to years); frequencies (10–10,000 Hz) and magnitudes (Shannon k from below zero to 4.47). Data from located entries indicate that a feline cortical model that employs acute stimulation might have limitations for assessing tissue damage in diverse anatomical locations, particularly for peripheral nerve and spinal cord simulation. PMID:28782181

  3. Public Regulatory Databases as a Source of Insight for Neuromodulation Devices Stimulation Parameters.

    PubMed

    Kumsa, Doe; Steinke, G Karl; Molnar, Gregory F; Hudak, Eric M; Montague, Fred W; Kelley, Shawn C; Untereker, Darrel F; Shi, Alan; Hahn, Benjamin P; Condit, Chris; Lee, Hyowon; Bardot, Dawn; Centeno, Jose A; Krauthamer, Victor; Takmakov, Pavel A

    2018-02-01

    The Shannon model is often used to define an expected boundary between non-damaging and damaging modes of electrical neurostimulation. Numerous preclinical studies have been performed by manufacturers of neuromodulation devices using different animal models and a broad range of stimulation parameters while developing devices for clinical use. These studies are mostly absent from peer-reviewed literature, which may lead to this information being overlooked by the scientific community. We aimed to locate summaries of these studies accessible via public regulatory databases and to add them to a body of knowledge available to a broad scientific community. We employed web search terms describing device type, intended use, neural target, therapeutic application, company name, and submission number to identify summaries for premarket approval (PMA) devices and 510(k) devices. We filtered these records to a subset of entries that have sufficient technical information relevant to safety of neurostimulation. We identified 13 product codes for 8 types of neuromodulation devices. These led us to devices that have 22 PMAs and 154 510(k)s and six transcripts of public panel meetings. We found one PMA for a brain, peripheral nerve, and spinal cord stimulator and five 510(k) spinal cord stimulators with enough information to plot in Shannon coordinates of charge and charge density per phase. Analysis of relevant entries from public regulatory databases reveals use of pig, sheep, monkey, dog, and goat animal models with deep brain, peripheral nerve, muscle and spinal cord electrode placement with a variety of stimulation durations (hours to years); frequencies (10-10,000 Hz) and magnitudes (Shannon k from below zero to 4.47). Data from located entries indicate that a feline cortical model that employs acute stimulation might have limitations for assessing tissue damage in diverse anatomical locations, particularly for peripheral nerve and spinal cord simulation. © 2017 International Neuromodulation Society.

  4. Thoracic spine localization using preoperative placement of fiducial markers and subsequent CT. A technical report.

    PubMed

    Anaizi, Amjad Nasr; Kalhorn, Christopher; McCullough, Michael; Voyadzis, Jean-Marc; Sandhu, Faheem A

    2015-01-01

    A retrospective case series evaluating the use of fiducial markers with subsequent computed tomography (CT) or CT myelography for intraoperative localization. To evaluate the safety and utility of preoperative fiducial placement, confirmed with CT myelography, for intraoperative localization of thoracic spinal levels. Thoracic spine surgery is associated with serious complications, not the least of which is the potential for wrong-level surgery. Intraoperative fluoroscopy is often used but can be unreliable due to the patient's body habitus and anatomical variation. Sixteen patients with thoracic spine pathology requiring surgical intervention underwent preoperative fiducial placement at the pedicle of the level of interest in the interventional radiology suite. CT or CT myelogram was then done to evaluate fiducial location relative to the level of pathology. Surgical treatment followed at a later date in all patients. All patients underwent preoperative fiducial placement and CT or CT myelography, which was done on an outpatient basis in 14 of the 16 patients. Intraoperatively, fiducial localization was easily and quickly done with intraoperative fluoroscopy leading to correct localization of spinal level in all cases. All patients had symptomatic improvement following surgery. There were no complications from preoperative localization or operative intervention. Preoperative placement of fiducial markers confirmed with a CT or CT myelogram allows for reliable and fast intraoperative localization of the spinal level of interest with minimal risks and potential complications to the patient. In most cases, a noncontrast CT should be sufficient. This should be an equally reliable means of localization while further decreasing potential for complications. CT myelography should be reserved for pathology that is not evident on noncontrast CT. Accuracy of localization is independent of variations in rib number or vertebral segmentation. The technique is a safe, reliable, and rapid means of localizing spinal level during surgery. Georg Thieme Verlag KG Stuttgart · New York.

  5. Comparison of Tibiofemoral Contact Mechanics After Various Transtibial and All-Inside Fixation Techniques for Medial Meniscus Posterior Root Radial Tears in a Porcine Model.

    PubMed

    Chung, Kyu Sung; Choi, Choong Hyeok; Bae, Tae Soo; Ha, Jeong Ku; Jun, Dal Jae; Wang, Joon Ho; Kim, Jin Goo

    2018-04-01

    To compare tibiofemoral contact mechanics after fixation for medial meniscus posterior root radial tears (MMPRTs). Seven fresh knees from mature pigs were used. Each knee was tested under 5 conditions: normal knee, MMPRT, pullout fixation with simple sutures, fixation with modified Mason-Allen sutures, and all-inside fixation using Fastfix 360. The peak contact pressure and contact surface area were evaluated using a capacitive sensor positioned between the meniscus and tibial plateau, under a 1,000-N compression force, at different flexion angles (0°, 30°, 60°, and 90°). The peak contact pressure was significantly higher in MMPRTs than in normal knees (P = .018). Although the peak contact pressure decreased significantly after fixation at all flexion angles (P = .031), it never recovered to the values noted in the normal meniscus. No difference was observed among fixation groups (P = .054). The contact surface area was significantly lower in MMPRTs than in the normal meniscus (P = .018) and increased significantly after fixation at all flexion angles (P = .018) but did not recover to within normal limits. For all flexion angles except 60°, the contact surface area was significantly higher for fixation with Mason-Allen sutures than for fixation with simple sutures or all-inside fixation (P = .027). At 90° of flexion, the contact surface area was significantly better for fixation with simple sutures than for all-inside fixation (P = .031). The peak contact pressure and contact surface area improved significantly after fixation, regardless of the fixation method, but did not recover to the levels noted in the normal meniscus after any type of fixation. Among the fixation methods evaluated in this time 0 study, fixation using modified Mason-Allen sutures provided a superior contact surface area compared with that noted after fixation using simple sutures or all-inside fixation, except at 60° of flexion. However, this study had insufficient power to accurately detect the differences between the outcomes of various fixation methods. Our results in a porcine model suggest that fixation can restore tibiofemoral contact mechanics in MMPRT and that fixation with a locking mechanism leads to superior biomechanical properties. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  6. Eighth international congress on nitrogen fixation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1990-01-01

    This volume contains the proceedings of the Eighth International Congress on Nitrogen Fixation held May 20--26, 1990 in Knoxville, Tennessee. The volume contains abstracts of individual presentations. Sessions were entitled Recent Advances in the Chemistry of Nitrogen Fixation, Plant-microbe Interactions, Limiting Factors of Nitrogen Fixation, Nitrogen Fixation and the Environment, Bacterial Systems, Nitrogen Fixation in Agriculture and Industry, Plant Function, and Nitrogen Fixation and Evolution.

  7. Eighth international congress on nitrogen fixation. Final program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1990-12-31

    This volume contains the proceedings of the Eighth International Congress on Nitrogen Fixation held May 20--26, 1990 in Knoxville, Tennessee. The volume contains abstracts of individual presentations. Sessions were entitled Recent Advances in the Chemistry of Nitrogen Fixation, Plant-microbe Interactions, Limiting Factors of Nitrogen Fixation, Nitrogen Fixation and the Environment, Bacterial Systems, Nitrogen Fixation in Agriculture and Industry, Plant Function, and Nitrogen Fixation and Evolution.

  8. Comparison of occipitocervical and atlantoaxial fusion in treatment of unstable Jefferson fractures.

    PubMed

    Hu, Yong; Yuan, Zhen-Shan; Kepler, Christopher K; Dong, Wei-Xin; Sun, Xiao-Yang; Zhang, Jiao

    2017-01-01

    Controversy exists regarding the management of unstable Jefferson fractures, with some surgeons performing reduction and immobilization of the patient in a halo vest and others performing open reduction and internal fixation. This study compares the clinical and radiological outcome parameters between posterior atlantoaxial fusion (AAF) and occipitocervical fusion (OCF) constructs in the treatment of the unstable atlas fracture. 68 consecutive patients with unstable Jefferson fractures treated by AAF or OCF between October 2004 and March 2011 were included in this retrospective evaluation from institutional databases. The authors reviewed medical records and original images. The patients were divided into two surgical groups treated with either AAF ( n = 48, F/M 30:18) and OCF ( n = 20, F/M 13:7) fusion. Blood loss, operative time, Japanese Orthopaedic Association (JOA) score, visual analog scale (VAS) score, atlanto-dens interval, lateral mass displacement, complications, and the bone fusion rates were recorded. Five patients with incomplete paralysis (7.4%) demonstrated postoperative improvement by more than 1 grade on the American Spinal Injury Association impairment scale. The JOA score of the AAF group improved from 12.5 ± 3.6 preoperatively to 15.7 ± 2.3 postoperatively, while the JOA score of the OCF group improved from 11.2 ± 3.3 preoperatively to 14.8 ± 4.2 postoperatively. The VAS score of AAF group decreased from 4.8 ± 1.5 preoperatively to 1.0 ± 0.4 postoperatively, the VAS score of the OCF group decreased from 5.4 ± 2.2 preoperatively to 1.3 ± 0.9 postoperatively. The OCF or AAF combined with short-term external immobilization can establish the upper cervical stability and prevent further spinal cord injury and nerve function damage.

  9. Evaluation of Titanium-Coated Pedicle Screws: In Vivo Porcine Lumbar Spine Model.

    PubMed

    Kim, Do-Yeon; Kim, Jung-Ryul; Jang, Kyu Yun; Kim, Min Gu; Lee, Kwang-Bok

    2016-07-01

    Many studies have addressed the problem of loosening pedicle screws in spinal surgery, which is a serious concern. Titanium coating of medical implants (arthroplasty) is common, but few studies involving in vivo spine models have been reported. We evaluated the radiological, mechanical, and histological characteristics of titanium-coated pedicle screws compared with uncoated or hydroxyapatite-coated pedicle screws. Three different types of pedicle screws, i.e., uncoated, hydroxyapatite-coated, and titanium-coated, were implanted into the lumbar 3-4-5 levels of 9 mature miniature pigs. Radiological evaluation of loosening of pedicle screws was performed. Peak torsional extraction torque was tested in the 42 screws from 7 miniature pigs at 12 weeks postoperatively. The implant-bone interface of the remaining 12 pedicle screws from 2 miniature pigs in each group was assessed by micro-computed tomography and histologic studies. The incidence of loosening at 12 weeks postoperatively was not significantly different between the titanium-coated pedicle screw group and the other groups. The titanium-coated pedicle screw group exhibited the greatest mean extraction torsional peak torque at 12 weeks postoperatively (P < 0.05). Quantitative micro-computed tomography data were greatest in the titanium-coated pedicle screw group (P < 0.05). Histologic findings showed osteointegration with densely packed new bone formation at the screw coating-bone interface in the titanium-coated pedicle screw group. Fixation strength was greatest in the titanium-coated pedicle screw group. Osteointegration at the interface between the titanium-coated implant and bone produced prominent and firm bonding. The titanium-coated pedicle screw is a promising device for application in spinal surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. [Postoperative visual loss due to conversion disorder after spine surgery: a case report].

    PubMed

    Bezerra, Dailson Mamede; Bezerra, Eglantine Mamede; Silva Junior, Antonio Jorge; Amorim, Marco Aurélio Soares; Miranda, Denismar Borges de

    Patients undergoing spinal surgeries may develop postoperative visual loss. We present a case of total bilateral visual loss in a patient who, despite having clinical and surgical risk factors for organic lesion, evolved with visual disturbance due to conversion disorder. A male patient, 39 years old, 71kg, 1.72 m, ASA I, admitted to undergo fusion and discectomy at L4-L5 and L5-S1. Venoclysis, cardioscopy, oximetry, NIBP; induction with remifentanil, propofol and rocuronium; intubation with ETT (8.0mm) followed by capnography and urinary catheterization for diuresis. Maintenance with full target-controlled intravenous anesthesia. During fixation and laminectomy, the patient developed severe bleeding and hypovolemic shock. After 30minutes, hemostasis and hemodynamic stability was achieved with infusion of norepinephrine, volume expansion, and blood products. In the ICU, the patient developed mental confusion, weakness in the limbs, and bilateral visual loss. It was not possible to identify clinical, laboratory or image findings of organic lesion. He evolved with episodes of anxiety, emotional lability, and language impairment; the hypothesis of conversion syndrome with visual component was raised after psychiatric evaluation. The patient had complete resolution of symptoms after visual education and introduction of low doses of antipsychotic, antidepressant, and benzodiazepine. Other symptoms also regressed, and the patient was discharged 12 days after surgery. After 60 days, the patient had no more symptoms. Conversion disorders may have different signs and symptoms of non-organic origin, including visual component. It is noteworthy that the occurrence of this type of visual dysfunction in the postoperative period of spinal surgery is a rare event and should be remembered as a differential diagnosis. Copyright © 2015 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  11. Revision extension to the pelvis versus primary spinopelvic instrumentation in adult deformity: comparison of clinical outcomes and complications.

    PubMed

    Fu, Kai-Ming G; Smith, Justin S; Burton, Douglas C; Kebaish, Khaled M; Shaffrey, Christopher I; Schwab, Frank; Lafage, Virginie; Arlet, Vincent; Hostin, Richard; Boachie, Oheneba; Akbarnia, Behrooz; Bess, Shay

    2014-01-01

    To evaluate the outcomes and complications of patients with adult spinal deformity treated in a primary versus revision fashion with long fusions to the sacropelvis. A retrospective review was performed of a multicenter consecutive series of patients with adult spinal deformity requiring fusion to the sacropelvis, either primarily or as revision, with minimum 2-year follow-up. Clinical (Scoliosis Research Society [SRS] 22 questionnaire) and radiographic parameters (including sagittal vertical axis [SVA], coronal Cobb angle, lumbar lordosis, and thoracic kyphosis) were compared between the groups. There were 63 patients who met inclusion criteria; mean patient age was 51.9 years, and mean follow-up was 43 months. Patients requiring primary fusion were older (58.0 years vs. 49.5 years, P=0.01) and at baseline had a lower SVA (2.1 cm vs. 6.8 cm, P=0.01) and greater thoracolumbar Cobb angle (51.2 degrees vs. 36.5 degrees, P=0.003). At last follow-up, patients undergoing primary fusion and patients undergoing revision treatment had similar SVA (2.9 cm vs. 1.8 cm, P=0.32) and lumbar lordosis (-42.3 degrees vs. -43.4 degrees, P=0.82); patients undergoing revision treatment had more favorable SRS 22 scores (3.65 vs. 3.14, P=0.005). There was no statistical difference in complication rates between the groups (44.4% vs. 35%, P=0.68). Patients requiring revision extension of instrumentation to the pelvis can be treated with the same expectation of radiographic and clinical success as patients treated primarily with fusion to the sacropelvis. The complication rate for the revision procedure is not insignificant and may be similar to a primary procedure that includes pelvic fixation. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Kyphectomy improves sitting and skin problems in patients with myelomeningocele.

    PubMed

    Garg, Sumeet; Oetgen, Matthew; Rathjen, Karl; Richards, B Stephens

    2011-05-01

    Progressive kyphosis occurs in up to 20% of patients with myelomeningocele. Severely affected patients can develop recurrent skin breakdown, osteomyelitis, sitting imbalance, and poor cosmetic appearance. We (1) assessed the ability of kyphectomy to restore an intact skin envelope and allow comfortable seating in a wheelchair; (2) reviewed the complications of kyphectomy and spinal fusion in myelomeningocele; and (3) determined whether patients requiring unexpected reoperation had worse correction or more ulceration compared with those patients treated with a single surgery. We retrospectively reviewed the records of 23 children with thoracic-level myelomeningocele who were treated with kyphectomy and spinal fusion since 1980. Indications for surgery included recurrent skin breakdown (15 patients) and poor sitting balance or unacceptable cosmetic deformity (three patients). We evaluated operative technique, type of sacropelvic fixation, surgical complications, radiographic correction, and skin condition at followup. The minimum followup was 2 years (median, 4.1 years; range, 2.1-10 years); 18 of the 23 children had greater than 2 years followup and are reported here. Kyphectomy achieved a sitting balance and resolved in skin ulceration in 17 of 18 patients. Seven patients had complications requiring reoperation. Three patients had multiple reoperations for early deep infection and one patient each had reoperation for late infection, pseudarthrosis, implant-related sacral pressure sore, and planned extension of proximal fusion after growth. Patients requiring multiple operations had similar correction and relief of ulceration to those treated with a single procedure. Complications after kyphectomy are frequent and many children with myelomeningocele and severe hyperkyphosis require multiple procedures and lengthy hospital stays. Nonetheless, improved seating balance and resolution of skin problems was achieved in 17 of 18 patients.

  13. Correction Capability in the 3 Anatomic Planes of Different Pedicle Screw Designs in Scoliosis Instrumentation.

    PubMed

    Wang, Xiaoyu; Aubin, Carl-Eric; Coleman, John; Rawlinson, Jeremy

    2017-05-01

    Computer simulations to compare the correction capabilities of different pedicle screws in adolescent idiopathic scoliosis (AIS) instrumentations. To compare the correction and resulting bone-screw forces associated with different pedicle screws in scoliosis instrumentations. Pedicle screw fixation is widely used in surgical instrumentation for spinal deformity treatment. Screw design, correction philosophies, and surgical techniques are constantly evolving to achieve better control of the vertebrae and correction of the spinal deformity. Yet, there remains a lack of biomechanical studies that quantify the effects and advantages of different screw designs in terms of correction kinematics. The correction capabilities of fixed-angle, multiaxial, uniaxial, and saddle axial screws were kinematically analyzed, simulated, and compared. These simulations were based on the screw patterns and correction techniques proposed by 2 experienced surgeons for 2 AIS cases. Additional instrumentations were assessed to compare the correction and resulting bone-screw forces associated with each type of screw. The fixed-angle, uniaxial and saddle axial screws had similar kinematic behavior and performed better than multiaxial screws in the coronal and transverse planes (8% and 30% greater simulated corrections, respectively). Uniaxial and multiaxial screws were less effective than fixed-angle and saddle axial screws in transmitting compression/distraction to the anterior spine because of their sagittal plane mobility between the screw head and shank. Only the saddle axial screws allow vertebra angle in the sagittal plane to be independently adjusted. Pedicle screws of different designs performed differently for deformity corrections or for compensating screw placement variations in different anatomic planes. For a given AIS case, screw types should be determined based on the particular instrumentation objectives, the deformity's stiffness and characteristics so as to make the best of the screw designs.

  14. Comparison of clinical outcomes of iris fixation and scleral fixation as treatment for intraocular lens dislocation.

    PubMed

    Kim, Kyeong Hwan; Kim, Wan Soo

    2015-09-01

    To compare the efficacy and safety of iris fixation with scleral fixation in surgical repositioning of dislocated intraocular lenses (IOLs). Retrospective, consecutive, comparative interventional case series. setting: Referral hospital. Seventy-eight consecutive patients who underwent surgical repositioning of dislocated intraocular lenses using suturing to the sclera or iris. Forty-four eyes of 44 patients underwent scleral fixation and 35 eyes of 34 patients underwent iris fixation of dislocated intraocular lenses. Visual acuity, refractive stability, operation time, and perioperative complications, including recurrence of IOL dislocation. Corrected distance visual acuity (CDVA) improved significantly 1 month postoperatively in both groups (P < .01 each), and remained stable for 12 months. One week postoperatively, however, CDVA improved significantly in the scleral fixation (P = .040) but not in the iris fixation (P = .058) group. The amount of refractive error significantly diminished 1 day after surgery (P = .028 in the scleral fixation and P = .046 in the iris fixation group). For the astigmatic components, Jackson crossed cylinders equivalent to conventional cylinders of positive power at axes of 0 degrees (J0) and 45 degrees (J45), J45 differed significantly in the scleral fixation and iris fixation groups (P = .009), whereas J0 was similar (P > .05). Operation time was significantly shorter (P = .0007), while immediate postoperative inflammation was significantly more severe (P = .001), in the iris fixation than in the scleral fixation group. Recurrence rates were similar (P > .05), but the mean time to recurrence was significantly shorter in the iris fixation than in the scleral fixation group (P = .031). Iris fixation and scleral fixation techniques had similar efficacy in the repositioning of dislocated intraocular lenses. Although operation time was shorter for iris fixation, it had several disadvantages, including induced astigmatism, immediate postoperative inflammation, earlier recurrence, and less stable refraction. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. [Posterior debridement and bone grafting via intervertebral space combined with internal fixation for the treatment of lumbosacral tuberculosis].

    PubMed

    Li, Wei-Wei; Liu, Jun; Duan, Liang; Duan, Da-Peng; Wei, Wen-Bo; Fan, Ya-Yi

    2017-02-25

    To explore the clinical effects of posterior debridement, bone grafting via intervertebral space combined with internal fixation for the treatment of lumbosacral tuberculosis. The clinical data of 32 patients with lumbosacral tuberculosis underwent the procedure of one-stage posterior intervertebral debridement, bone grafting and internal fixation from January 2007 to July 2013 were retrospectively analyzed. There were 17 males and 15 females, aged from 27 to 63 years with an average of (49.8±9.2) years. The course of disease was from 5 to 18 months with the mean of (10.7±3.2) months. There was involved the vertebral body of L₅ in 1 case, the intervertebral space of L₅S₁ in 8 cases, and the vertebral body of L₅ or S₁ combined with intervertebral space of L₅S₁ in 23 cases. VAS, ESR, CRP, the lumbosacral angle, the height of intervertebral space of L₅S₁, and ASIA grade were used to evaluate clinical effects. All the patients were followed up from 18 to 39 months with an average of 21.6 months. Operative time was 120 to 260 min with the mean of 175 min, and intraoperative bleeding was 700 to 1 450 ml with the mean of 1 050 ml. VAS before operation was 8.4±1.6, then descended to 3.5±0.8( P <0.05) on the 3rd month after operation and redescended to the level of 1.7±0.6( P <0.05) at the final follow-up. The ESR and CRP before operation were (48.8±10.2) mm and (58.6±5.6) mg/L, respectively, then decreased to (35.6±6.9) mm and (22.5±4.3) mg/L ( P <0.05) at the 3rd month after operation and returned to the normal level at the final follow-up. The height of intervertebral space of L₅S₁ and lumbosacral angle before operation were (7.7±0.4) mm and (19.3±1.2)°, respectively, then improved to (10.3±0.3) mm and (22.4±1.5)° on the 3rd month after operation( P <0.05), and maintained such level, no obvious lost at later. According to ASIA grade, 8 cases were grade C, 19 were grade D, 5 were grade E before operation, and at final follow-up, 1 case still was grade D, others were grade E. The procedure of posterior debridement, bone grafting via intervertebral space combined with internal fixation is an effective and safe method in treating lumbosacral tuberculosis, it can effectively debride tuberculose focus, maintain the spinal stability, and improve the dysfunction with less complication.

  16. Reverse Anterior Cruciate Ligament Reconstruction Fixation: A Biomechanical Comparison Study of Tibial Cross-Pin and Femoral Interference Screw Fixation.

    PubMed

    Lawley, Richard J; Klein, Samuel E; Chudik, Steven C

    2017-03-01

    To evaluate the biomechanical performance of tibial cross-pin (TCP) fixation relative to femoral cross-pin (FCP), femoral interference screw (FIS), and tibial interference screw (TIS) fixation. We randomized 40 porcine specimens (20 tibias and 20 femurs) to TIS fixation (group 1, n = 10), FIS fixation (group 2, n = 10), TCP fixation (group 3, n = 10), or FCP fixation (group 4, n = 10) and performed biomechanical testing to compare ultimate load, stiffness, yield load, cyclic displacement, and load at 5-mm displacement. We performed cross-pin fixation of the looped end and interference screw fixation of the free ends of 9-mm-diameter bovine extensor digitorum communis tendon grafts. Graft fixation constructs were cyclically loaded and then loaded to failure in line with the tunnels. Regarding yield load, FIS was superior to TIS (704 ± 125 N vs 504 ± 118 N, P = .002), TCP was superior to TIS (1,449 ± 265 N vs 504 ± 118 N, P < .001), and TCP was superior to FCP (1,449 ± 265 N vs 792 ± 397 N, P < .001). Cyclic displacement for FCP was superior to TCP. Cyclic displacement for TIS versus FIS showed no statistically significant difference (2.5 ± 1.0 mm vs 2.2 ± 0.6 mm, P = .298). Interference screw fixation consistently failed by graft slippage, whereas TCP fixation failed by tibial bone failure. FCP fixation failed by either femoral bone failure or failure elsewhere in the testing apparatus. Regarding yield load, TCP fixation performed biomechanically superior to the clinically proven FCP at time zero. Because TIS fixation shows the lowest yield strength, it represents the weak link, and combined TCP-FIS fixation theoretically would be biomechanically superior relative to combined FCP-TIS fixation with regard to yield load. Cyclic displacement showed a small difference in favor of FCP over TCP fixation and no difference between TIS and FIS. Time-zero biomechanics of TCP fixation paired with FIS fixation show that this method of fixation can be considered a potential alternative to current practice and may pose clinical benefits in different clinical scenarios of anterior cruciate ligament reconstruction. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  17. Eye-tracking computer systems for inpatients with tetraplegia: findings from a feasibility study.

    PubMed

    van Middendorp, J J; Watkins, F; Park, C; Landymore, H

    2014-12-02

    Study design:A longitudinal, prospective, self-controlled cohort study.Objectives:To determine (1) the preliminary benefits of using eye-tracking computer systems (ETCSs) among inpatients with tetraplegia and (2) the feasibility of carrying out a well-powered randomized controlled trial.Setting:Specialist Spinal Cord Injuries Centre, United Kingdom; 6 months during 2013-2014.Methods:Individuals with tetraplegia who were admitted to the center and enrolled in this study were trained and allowed to use the ETCS (Tobii Eyegaze C15 System) twice a week for a duration of 10 weeks. Standardized training modules were developed and offered to all study participants. Study feasibility indicators as well as the Appraisals of Disability: Primary and Secondary Scale, Hospital Anxiety and Depression Scale and the Assistive Technology Device Predisposition Assessment questionnaire scores were taken before and after study enrollment.Results:A total of 31 inpatients with tetraplegia were screened. Although 14 patients (45%) met the study eligibility criteria, 6 patients (19%) consented to be enrolled in the study. Three participants did not complete the planned training schedule because of medical, technical and logistic reasons. Although half of the participants agreed that the ETCS under study was easy to use, no substantial improvements were seen in terms of psychological outcomes, appraisals of disability or independence.Conclusions:The conduct of a controlled trial evaluating the benefits of using ETCSs among newly injured patients with tetraplegia comes with considerable feasibility challenges. Until substantial technical improvements of ETCSs have been implemented, future research should initially focus on those individuals with tetraplegia who are living in the community and who have expressed a need to enhance their computer access and communication skills.Spinal Cord advance online publication, 2 December 2014; doi:10.1038/sc.2014.219.

  18. Innovative Technique for the Placement of the Drainage Tube for Microendoscopic Spinal Decompression.

    PubMed

    Mizuno, Kentaro; Mikami, Yasuo; Hase, Hitoshi; Ikeda, Takumi; Nagae, Masateru; Tonomura, Hitoshi; Shirai, Toshiharu; Fujiwara, Hiroyoshi; Kubo, Toshikazu

    2017-02-01

    A technical note and retrospective study. The objectives were to describe a new method of drainage tube placement during microendoscopic spinal decompression, and compare the positioning and fluid discharge obtained with this method and the conventional method. To prevent postoperative epidural hematoma after microendoscopic decompression, a drainage tube must be placed in a suitable location. However, the narrow operative field makes precise control of the position of the tube technically difficult. We developed a method to reliably place the tube in the desired location. We use a Deschamps aneurysm needle with a slightly curved tip, which we call a drain passer. With the microendoscope in position, the drain passer, with a silk thread passed through the eye at the needle tip, is inserted percutaneously into the endoscopic field of view. The drainage tube is passed through the loop of silk thread protruding from the inside of the tubular retractor, and the thread is pulled to the outside, guiding the end of the drainage tube into the wound. This method was used in 23 cases at 44 intervertebral levels (drain passer group), and the conventional method in 20 cases at 32 intervertebral levels (conventional group). Postoperative plain radiographs were taken, and the amount of fluid discharge at postoperative hour 24 was measured. Drainage tube positioning was favorable at 43 intervertebral levels (97.7%) in the drain passer group and 26 intervertebral levels (81.3%) in the conventional group. Mean fluid discharge was 58.4±32.2 g in the drain passer group and 38.4±23.0 g in the conventional group. Positioning was significantly better and fluid discharge was significantly greater in the drain passer group. The results indicate that this method is a useful drainage tube placement technique for preventing postoperative epidural hematoma.

  19. Comparison of Risk of Carpal Tunnel Syndrome in Patients with Distal Radius Fractures After 7 Treatments

    PubMed Central

    Zhao, Huan-Li; Wang, Gui-Bin; Jia, Yue-Qing; Zhu, Shi-Cai; Zhang, Feng-Fang; Liu, Hong-Mei

    2015-01-01

    Background To compare risk of carpal tunnel syndrome (CTS) in distal radius fracture (DRF) patients after 7 treatments using bridging external fixation (BrEF), non-bridging external fixation (non-BrEF), plaster fixation, K-wire fixation, dorsal plating fixation, volar plating fixation, and dorsal and volar plating by performing a network meta-analysis. Material/Methods An exhaustive search of electronic databases identified randomized controlled trails (RCTs) closely related to our study topic. The published articles were screened, based on predefined inclusion and exclusion criteria, to select high-quality studies for the present network meta-analysis. Data extracted from the selected studies were analyzed using STATA version 12.0 software. Results The literature search and selection process identified 12 eligible RCTs that contained a total of 1370 DRF patients (394 patients with BrEF, 377 patients with non-BrEF, 89 patients with K-wire fixation, 192 patients with plaster fixation, 42 patients with dorsal plating fixation, 152 patients with volar plating fixation, and 124 patients with dorsal and volar plating fixation). Our network meta-analysis results demonstrated no significant differences in CTS risk among the 7 treatments (P>0.05). The value of surface under the cumulative ranking curve (SUCRA), however, suggested that dorsal plating fixation is the optimal treatment, with the lowest risk of CTS in DRF patients (dorsal plating fixation: 89.2%; dorsal and volar plating: 57.8%; plaster fixation: 50.9%; non-BrEF: 50.6%; volar plating fixation: 39.6%; BrEF: 38.4%; K-wire fixation: 23.6%). Conclusions Our network meta-analysis provides evidence that dorsal plating fixation significantly decreases the risk of CTS and could be the method of choice in DRF patients. PMID:26391617

  20. Single-screw Fixation of Adolescent Salter-II Proximal Humeral Fractures: Biomechanical Analysis of the "One Pass Door Lock" Technique.

    PubMed

    Miller, Mark Carl; Redman, Christopher N; Mistovich, R Justin; Muriuki, Muturi; Sangimino, Mark J

    2017-09-01

    Pin fixation of Salter-II proximal humeral fractures in adolescents approaching skeletal maturity has potential complications that can be avoided with single-screw fixation. However, the strength of screw fixation relative to parallel and diverging pin fixation is unknown. To compare the biomechanical fixation strength between these fixation modalities, we used synthetic composite humeri, and then compared these results in composite bone with cadaveric humeri specimens. Parallel pinning, divergent pinning, and single-screw fixation repairs were performed on synthetic composite humeri with simulated fractures. Six specimens of each type were tested in axial loading and other 6 were tested in torsion. Five pair of cadaveric humeri were tested with diverging pins and single screws for comparison. Single-screw fixation was statistically stronger than pin fixation in axial and torsional loading in both composite and actual bone. There was no statistical difference between composite and cadaveric bone specimens. Single-screw fixation can offer greater stability to adolescent Salter-II fractures than traditional pinning. Single-screw fixation should be considered as a viable alternative to percutaneous pin fixation in transitional patients with little expected remaining growth.

Top